﻿_id	PERMIT_NBR	PRIMARY_ADDRESS	ZIP_CODE	CD	PIN_NBR	APN	ZONE	APC	CPA	CNC	HL	CT	PERMIT_GROUP	PERMIT_TYPE	PERMIT_SUB_TYPE	USE_CODE	USE_DESC	SUBMITTED_DATE	ISSUE_DATE	COFO_DATE	STATUS_DESC	STATUS_DATE	TYPE_LAT_LON	LAT	LON	WORK_DESC	ev	solar	business_unit	REFRESH_TIME
1	18041-20000-08076	16531 W GREENLEAF ST	91436	5	168B137   461	2284005022	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Re-Activate Permit	10/23/2018 12:00:00 AM	ADDRESS	34.15605	-118.49339	Plan check for a PV1 roof-mounted PV system. System size is 10.45 kWac and consists of (2) inverters, (29) modules, (3) load centers, and (2) PowerWalls.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2	18041-20000-13607	2507 N ROSCOMARE ROAD	90077	5	156B145   277	4378016018	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.12215	-118.46508	PV1.  Install 11.05 kW roof mounted grid tied PV system.  (34) modules with 3.8 and 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3	18041-10000-24118	601 W 5TH ST 11 floor	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.05049	-118.25386	T.I TO SUITE 1100 ON THE 11TH FLOOR TO INCLUDE (N) PARTIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4	17041-10000-21796	3055 E 12TH ST	90023	14	118-5A223  56	5169005021	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.01936	-118.21378	TItle 24 plan check.  Replace existing fixtures with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5	19041-10000-43514	1223 N EDGEMONT ST	90029	13	144B197   172	5540011015	R3-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Apartment			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	10/26/2020 12:00:00 AM	ADDRESS	34.09407	-118.29636	PLAN CHECK FOR FIRE ALARM SYSTEM. 28 DEVICES AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6	11041-10000-25530	22852 W MACFARLANE DR	91364	3	171B097   977	2075017027	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2011 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.16168	-118.62433	New 7.8KW rooftop Photovoltaic system for a single family dwelling with Enphase M215 Microinverters.  Variance to install M215 prior to Test Lab approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7	15041-20000-02718	10850 W BLOOMFIELD ST	91602	4	165B173   487	2423019010	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			01/29/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.14907	-118.36695	New 4-story, Type V-A, 28-unit apartment 1200 amp service.  plan check for power and energy. fire alarm variance has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8	19041-10000-51941	1 S LMU DR BLDG B	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM	09/16/2020 12:00:00 AM		Permit Finaled	03/15/2021 12:00:00 AM	ADDRESS	33.96577	-118.42406	"NEW FIRE ALARM SYTEM IN AN APARTMENT BUILDING ""B"" WHICH INCLUDES OVER 1001 DEVICES. BUILDING ""A"" UNDER PLAN CHECK NUMBER 19041-10000-51938"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9	14041-20001-06247	22450 W CALIFA ST	91367	3	174B101    44	2040040007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.17678	-118.61642	((EXPEDITE FEES))PV1 ROOFMOUNTED TRANSFORMERLESS SYSTME. TOTAL SYSTEM SIZE 9.6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10	19041-20000-38686	8255 W BEVERLY BLVD	90048	5	138B173   390	5514009055	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.07623	-118.36921	TI to (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11	12041-10000-03430	1630 N MAIN ST Bldg 3	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Expired	05/22/2014 12:00:00 AM	PIN	34.06623967	-118.22749482	INSTALL A NEW STEP UP 112.5 KVA, 240:480, 3Ph TRANSFORMER AND A NEW PANEL ON THE ROOF FOR FUTURE LOADS.  APPLICANT (LADWP) IS REQUESTING PLAN CHECK,  <<< EPC FOR POWER. >>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12	14041-20001-29360	5366 N TOPANGA CANYON BLVD	91364	3	171B101   241	2169003002	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.16787	-118.60555	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT. BARBER SHOP. 1700 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13	15041-10000-14632	333 S HOPE ST FLR 26	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Issued	05/26/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO OFFICES AND COMMON AREAS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. SCOPE OF WORK TO BE PERFORMED IN FLOOR 26.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14	19041-20001-24024	5155 N KELVIN AVE	91364	3	171B109   190	2166031006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.16413	-118.58497	10-16-2019 Changes to an approved set of plan, changes include relocate Tesla Power Walls. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15	18041-20000-45128	6082 E YORK BLVD	90042	14	154-5A231 162	5484027012	[Q]C4-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.11747	-118.18674	Plan check for new fire alarm for daycare area. new fire alarm devices: 33 with 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16	12041-10002-12382	221 S GRAND AVE	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.05419	-118.2505	(((CHANGES MADE TO APPROVED SET. DELTA-4 AND DELTA-5 CHANGES.))) 10/03/13(((CHANGES MADE TO APPROVED SET. CHANGING EST3 GENESIS TO WHEEL LOCK (SPEAKER STROBES.)))New fire alarm system for Broad Museum.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17	13041-20000-35046	2020-2040 N VESTAL AVE	90026	13	144A211   186	5420016006	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM			PC Approved	05/14/2014 12:00:00 AM	ADDRESS	34.08914	-118.25187	PC FOR MULTIPLE SINGLE FAMILY DWELLINGS ON ONE TRACT. EACH UNIT PER BUILDING IS ONE SINGLE FAMILY DWELLING. EACH UNIT WILL GET INDIVIDUAL SERVICE FROM DWP. PLAN CHECK FOR ENTIRE PLAN PER APPLICANT REQUEST. PERMIT ALREADY ISSUED UNDER THE BUILDING PERMITS. THIS APPLICATION IS FOR PLAN CHECK ONLY. NO PERMIT TO BE ISSUED FROM THIS APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18	13041-10000-11757	15541 W VINCENNES ST	91343	7	198B145    94	2656015011	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.24107	-118.47112	PV1. Plan check for new installation 10.78 KW roof mounted photovoltaic system.   Total of 4 strings installed on single story guest house and garage roofs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19	10041-10000-13111	14600 W SHERMAN WAY # 100A &-# 100C	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	ADDRESS	34.20095	-118.45113	MEDICAL OFFICE T.I. ON FIRST FLOOR (3,800 S.F.). PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20	15041-20000-27141	13812 W DAVANA TER	91423	4	165B153   840	2266022005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1411.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Closed	11/12/2015 12:00:00 AM	ADDRESS	34.14636	-118.43389	PV1. Install roof mounted PV system sized 17 kW. Interconeccted with main service panel. (74) Hyundai HIS-S270 Modules(2) ABB PVI-6000 Inverter(1) ABB PVI-5000 InverterNote: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21	17041-20000-04152	9223 N LEMONA AVE	91343	7	198B145   278	2651001019	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.238	-118.45904	100A 120/240V 1ph-3w service for residential tract site lighting/irrigation controller.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22	19041-10000-28615	3575 N CAHUENGA BLVD W STE#605	90068	4	159B177   196	2425008023	C2-1VL, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	PIN	34.13362778	-118.35843173	FULL PLAN CHECK FOR A TI TO AN EXISTING OFFICE. SCOPE INCLUDES NEW 150KVA TRANSFORMER, EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL CONNECTED LOAD IS MORE THAN 400A. TOTAL AFFECTED AREA IS 11020 SQ.FTB#19016-10000-20101	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23	15041-10001-01360	200 WORLD WAY TERM 2-DEPT LEV 3	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM			PC Approved	03/09/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Revisions to approved set.  Lighting fixture schedule and lighting design revised. (((TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 DEPT  LEV 3  SPACE 223PLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24	14041-20000-33484	7122 N RANCHITO AVE	91405	2	183B153   277	2216031036	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.19997	-118.43516	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING 16 MODULES. USING TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25	13041-20000-32417	15121 W RAYEN ST	91343	7	195B145   233	2654006033	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Apartment			11/19/2013 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.23199	-118.4617	PC FOR NEW APARTMENT. 20 UNITS. POWER ONLY. FIRE ALARM VARIANCE HAS BEEN FILED. NO COMMON PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26	17041-20000-25171	1440 S SEPULVEDA BLVD	90025	5	129B149    38	4324016094	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.05107	-118.44699	one for one replacement of existing ups.  plan check requested by applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27	15041-20001-43229	4960 N BEN AVE	91607	2	171B165  1156	2355011001	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.16104	-118.39418	Expedite feePV1 roof top installation, 11kW AC(57) KU2656ZPA( 1) PVI-5000-OUTD-US-Z( 1) PVI-6000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28	12041-10002-15061	1600 N WESTERN AVE	90027	13	148-5A193 302	5544022035	[Q]R5-2	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			03/07/2014 12:00:00 AM			PC Approved	03/07/2014 12:00:00 AM	ADDRESS	34.10004	-118.30899	CHANGES TO APPROVED SET PER INSPECTORS REQUEST. ADD NOTE INDICATING SER CABLES. SER FEEDERS TO BE ONLY ROUTED INDOORS. DELTA 4 CHANGES ONLY. CHANGES ARE CLOUDED.Plan check power and energy for new 4-story 40 unit apartment with 1600A service. Modification to separate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29	17041-20000-18847	865 S FIGUEROA ST 3rd Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for Title 24 only. Project site is a portion of the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,327 sq. ft.Note: Building permit has been issued under 17016-10000-10157	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30	15041-20000-03664	1513 S GRAND AVE	90015	14	124-5A207 123	5134015027	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.03622	-118.26632	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO (E) MEDICAL OFFICE.suite 220 and 250BUILDING P# 14016-20000-19261	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31	15041-20000-38331	1238 W 50TH ST	90037	9	111B197  1136	5017010021	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	33.99767	-118.29731	PV1, roof mounted solar panel, 3.75kWAC system   (15)modules: SW285 MONO    (15)microinverters: Enphase M250 .  standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32	19041-10001-05298	6020 W 83RD PL	90045	11	096B169    53	4107026022	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	33.96279	-118.39001	Plan check for a roofmounted TILE PV system with (3) strings, (2) inverters, and (2) power supplies interconnecting through the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33	16041-20000-07499	20334 W CHASE ST	91306	3	192B113   215	2781023001	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	PIN	34.22441031	-118.57682679	Plan check for the addition of a PV1 roof-mounted PV 3 kWac system onto an existing 9 kWac PV system, for a total system size of 12 kWac. Addition consists of (1) inverter, (8) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34	16041-10000-18914	1338 S FLOWER ST	90015	14	126A207   190	5134011025	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.03895	-118.26732	PC for T-24 only. Remove HID fixtures and replace with new LED fixtures. Total area: 7,751 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35	11041-10000-15416	1 S LMU DR FOLEY-ANNEX	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	T24 lighting plan check for Foley Annex. PERMIT INCLUDE LOW VOLTAGE  FOR 63 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36	11041-10000-23888	13949 W VENTURA BLVD Suite #250	91423	5	165B153   438	2271014006	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			11/08/2011 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.14916	-118.43708	NEW DENTAL OFFICE ON THE 2ND FLOOR (Suite #250).  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37	12041-10000-22866	3601 N ROYAL WOODS DR	91403	5	159B141    48	2280014029	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2012 12:00:00 AM	03/04/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.13576	-118.47333	PLAN CHECK NEW 4.23KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING KACO BLUE PLANET TRANSFORMERLESS INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38	11041-20000-23698	3600 W WILSHIRE BLVD Ste 100C	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	34.06156	-118.30335	T.I.  Remodel of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39	18041-10000-42826	4000 E CHEVY CHASE DR	90039	13	159B205   295	5594015019	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.13328	-118.27096	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40	16041-20000-24527	1822 N WESTRIDGE ROAD	90049	11	135B137   233	4426009003	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Expired	09/13/2018 12:00:00 AM	ADDRESS	34.06718	-118.49757	Plan check for PV roof mounted system. System size: 14kW with 50 microinverters (Enphase S280).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41	17041-10000-41089	17431 W ROSCOE BLVD	91325	12	192B129   252	2787018006	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.22122	-118.5136	REPLACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42	13041-10000-30293	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.01925	-118.37654	T.I. to existing building for Time Warner.  Install 1200A distribution panel for rectifier equipment.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43	14041-10000-33097	8876 W VENICE BLVD	90034	10	123B169  1385	4312015005	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.02984	-118.38677	Full plan check for a commercial/ industrial building T.I and service upgrade to 2500-Amp with existing load reconnected to the new service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44	19041-10000-25649	18749 W GAULT ST	91335	3	183B121   293	2126003017	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Closed	10/04/2022 12:00:00 AM	ADDRESS	34.19941	-118.54207	pc for pv-1, 21 modules with 320w optimizier.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45	16041-20004-02117	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	34.0965	-118.30717	CHANGES TO APPROVED SET.  CORE AND SHELL DRAWINGS UPDATED TO REFLECT EXISTING EQUIPMENT IN 1ST, 2ND, AND 3RD FLOOR RESTROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46	16041-10009-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	PIN	34.2363795	-118.55851216	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE UNDER BULLETIN 26. NARRATIVE HAS BEEN PROVIDED FOR ALL CHANGES.  NOTE: APPLICANT IS REQUESTING MASTER PLAN CHECKER FRANCIS YSAGUIRRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47	15041-20000-38184	7931 N VARIEL AVE	91304	3	189B105   262	2109017016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.21469	-118.593	PV1, roof mounted solar panel, 6.89kW DC system (26)modules #KU2656ZPA, (1)inverter:PVI-6000-OUTD-US-Z-AStandard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48	15041-20000-05477	3039 S POTOMAC AVE	90016	10	120B181   604	5057021019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.02647	-118.34405	Installation of new roof mounted solar PV microinverter array.  Total system size = 3.12 kWac (1 branch circuit with 13 modules)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49	12041-10000-00396	5519 N LAUREL CANYON BLVD	91607	2	174B165   858	2347015002	R3-1, [Q]C1.5-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			01/06/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.17066	-118.3967	Plan check 39.84KW roof mounted photovoltaic system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50	18041-20002-25635	18460 W ROSCOE BLVD	91325	12	192B125   934	2102001018	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM			PC Info Complete	07/25/2019 12:00:00 AM	ADDRESS	34.22046	-118.53569	07-25-2019 Changes to an approved set of plan, Changes include light layout and update title 24 calculation, additon of branch circuit. All change has been clouded as delta 4 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51	13041-20000-26607	2035 N HIGHLAND AVE	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.10759	-118.3376	PV2 COMMERCIAL BUILDING. PV SYSTEM. TOTAL SYSTEM SIZE 7.7KW AC USING ENPHASE MICROINVERTERS. NONSTANDARD PLAN.  15 KVA TRANSFORMER IS PART OF PV SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52	15041-20000-03153	3440 W WINSLOW DR	90026	13	144A203   388	5427028002	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.08709	-118.27762	PV1. ROOFMOUNTED SOLAR SYSTEM. 5KW AC(14) SP 327NE MODULES(1) POWER ONE PVI-5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53	11041-10001-10296	1025 N HIGHLAND AVE 14th fl	90038	4	144B185   830	5532028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.08969	-118.33884	Change the six CF luminaire FA/35 to six MR-16 FA/50 as shown on the plan and light fixture schedule, and LTG compliance forms.   Also, add one additional 120 volt circuit to supply 5 FA/50.  No other changes to the plan or lighting layout. See plan delta GC for items reviewed as part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54	19041-10001-04301	19700 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Closed	07/17/2019 12:00:00 AM	ADDRESS	33.85221	-118.2903	CHANGE TO AN APPROVED SET, CHANGE UNDER DELTA-1. CHANGE INCLUDES ADDING 2 DEVICES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55	18041-10000-12898	865 S FIGUEROA ST #3339,3345	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLAN CHECCK FOR TITLE 243 ONLY FOR TI NON-STRUCTURAL ALTERATIONS TO EXISTING OFFICE TENANT IMPROVEMENTS. TOTAL AFFECTED AREA 1740SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56	12041-10000-12589	7454 W HILLSIDE AVE	90046	4	150B181   590	5572027018	RE9-1	Central	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.10451	-118.35225	nEW 5.17KW ROOFTOP PHOTOVOLTAIC SYSTEM FOR AN EXISTING SINGLE FAMILY RESIDENCE.  SYSTEM USES ENPHASE MIRCO-INVERTERS, AND TRENCHING FROM A GARAGE STRUCTURE,  NOT A METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57	13041-10001-36330	19913 W MARTHA ST	91367	3	174B113   291	2153017019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Verifications in Progress	02/26/2014 12:00:00 AM	ADDRESS	34.17348	-118.56639	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS W/ OPTOMIZERS. SYSTEM SIZE: 6.5KW DC.(26) TRINA SOLAR TSM-250(1) SOLAR EDGE SE 6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58	15041-10002-12226	811 W 7TH ST	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.04908	-118.25911	Change to approved set by modifying all emergeny exist signs with (1) normal circuit and an emergency circuit. Panels also being updated with modification. All changes are under delta-2 only. (((TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW AND EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2800.  SCOPE OF WORK TO BE PERFORMED IN FLOORS 2,9,10,12 PLUS PENTHOUSE ONLY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59	11041-10000-24159	2180 S WESTWOOD BLVD	90025	5	126B157   253	4321012071	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/10/2011 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	ADDRESS	34.04421	-118.4318	T.I. for existing building.  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60	19041-10000-22954	4219 N MARMION WAY	90065	1	145-5A223  21	5465015012	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.09479	-118.21049	"[E-PLAN] PV1. NEW ROOFTOP SOLAR SYSTEM WITH TESLA POWER WALL BATTERY. SYSTEM CONSIST OF 12 MODULES, 12 OPTIMIZERS AND 1 CENTRAL INVERTER. SYSTEM SIZE IS 4.32KWdc AND 5KWac.""SERVICE UPGRADE SHALL BE DONE SEPERATELY THROUGH EXPRESS PERMIT"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61	12041-20000-26568	865 S FIGUEROA ST	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for energy and emergency lighting. Commercial high rise. 11th floor. Davis Elen Advertising.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62	17041-20000-04951	648 S BROADWAY	90014	14	127-5A211  32	5144002023	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.0454	-118.25294	Facade lighting for commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63	13041-20000-11712	3323 W WASHINGTON BLVD	90019	10	126B189   896	5072029016	[Q]CM-1VL-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			Corrections Issued	05/20/2013 12:00:00 AM	PIN	34.04018247	-118.32097157	Change to lighting Only in an Existing low-rise office building.  Load is 200 amps per applicant.  Plan Check Only for Energy.  There is NO Emergency lighting in the space per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64	17041-20002-45197	6150 N LAUREL CANYON BLVD Bldg H	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	08-09-2019 Changes to an approved set of plan, Changes include revise grounding details between transformer to building distribution, loop distribution overcurrent device protection ratings to address coordination, and miscellaneous SLD revisions to reflect current filed conditons. All Changes has been clouded as delta 7 and 8. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65	12041-10003-30779	"12746 W JEFFERSON BLVD ""4"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM			PC Approved	02/23/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Change of lighting fixtures in public access roadway lighting and in level 1 parking of building 4.  All changes on this supplemental limited to delta-C revisions.  Affected sheets:E1.0.03E1.0.06E2.2.01E6.3.01E8.4.01(((Plan check power and energy for Building 4. Five story parking garage building with common subterranean parking to Building 1, 2, 3, and 4. Service supply from Building 3. Site located in methane zone. Modification to separate fire alarm system has been filed.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66	10041-10000-13477	2029 S CENTURY PARK EAST 29th floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	07/23/2010 12:00:00 AM		Permit Finaled	09/27/2010 12:00:00 AM	ADDRESS	34.05956	-118.41375	Ti in an existing office building. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67	11041-10000-04590	10201 W PICO BLVD BLDG#101	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Expired	05/21/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	Ti in the FOX technical operation center. This  Phase  3 of the project (total of 5). EPC is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68	12041-10000-18834	751 N FAIRFAX AVE 1st Floor	90046	5	141B177  1448	5527012***	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	34.08526	-118.36177	"FIRST TIME TENANT RETAIL SPACE ON THE FIRST FLOOR.  COMBINE EXISTING THREE 100AMP FEEDERS IN TO ONE 200AMP FEEDER TO THE NEW ""FISH BOWL"" RETAIL SPACE AND REMOVE TWO OTHER 100 AMP FEEDERS. PLAN CHECK FOR POWER AND ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69	19041-30000-08910	1644 S MALCOLM AVE	90024	5	129B153  1417	4325025***	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			03/12/2019 12:00:00 AM	05/12/2020 12:00:00 AM		Permit Finaled	11/03/2022 12:00:00 AM	ADDRESS	34.05302	-118.43703	Plan check for power and energy. Project site is a 6-story, 14-unit building over 1 level of subterranean parking garage. Work includes a 2,000-amp service and a total lighting area of 24,641 sq. ft.Note: Building permit has been issued under 17010-10000-02885	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70	15041-10000-42966	1875 CENTURY PARK EAST 3rd floor	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	PIN	34.06139196	-118.41527843	PC for energy only to a commercial site (offices) Work is being done on the 3rd floor. Adding lighting and power. Total Sq ft = 8778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71	14041-20000-29928	5939 N KELVIN AVE	91367	3	177B109    37	2149012010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.179	-118.58354	PV1Using microinverter standard plan.Install roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 7.2kW. 30 EnPhase M250 microinverters and 30 275W pv modules across two strings (15+15).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72	18041-20000-34353	18000 W DEVONSHIRE ST	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.25698	-118.52508	ti to an existing commercial building. replacing existing light fixtures to LED with retrofit kits.  plan check for indoor energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73	17041-20001-41596	180 S LA BREA AVE	90036	5	138B181  1246	5513018017	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.07124	-118.34383	Revisions to approved set.  Lighting system redesign.  Plan check for energy. (((PC FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY!SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 1972 SQ.FTB# 17016-10000-27740INTERIOR TI  <<SECOND  RESTAURANT(1670SF)  CONSTRUCTED WITH NEW DEMISING WALL(17016-10000-16799) WITHIN EXISTING RESTAURANT TENANT SPACE>>)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74	14041-10000-07239	11995 W BLUFF CREEK DR	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35606.BLDG PERMIT: 13010-10000-04244	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75	15041-20001-41180	7902 N WOODLEY AVE	91406	6	189B141   151	2206007008	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM			PC Approved	01/04/2016 12:00:00 AM	ADDRESS	34.21417	-118.48347	Supplemental PC for Power - Control Receptacles. Permit under 15041-20000-41180((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERICIAL BUILDING (OFFICE/STORAGE/RESTROOM SPACE). SCOPE INCLUDES ADDING NEW LIGHTING. TOTAL AREA IS 2032 SQ. FT.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76	15041-20000-07444	14301 W BLEDSOE ST	91342	7	228B153   101	2502025002	A1-1-K, RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.32368	-118.44497	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77	19041-20000-41170	2101 S DUXBURY CIR	90034	5	126B165    81	4309009031	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	34.04462	-118.39512	PV1.  Install 10.22 kW rated roof mounted grid tied PV system.  (28) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
78	18041-20000-44354	7120 N HAYVENHURST AVE	91406	6	183B137    95	2224017027	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.1997	-118.49221	Plan check for Title 24 only in under photovoltaic carport structures. Total area: 8491 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
79	13041-20002-23238	616 N LA JOLLA AVE	90048	5	141B173   733	5528011014	R1-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2013 12:00:00 AM			PC Approved	12/30/2013 12:00:00 AM	ADDRESS	34.08205	-118.36785	New rooftop PV System on an existing 2-unit residential building.  System uses Enphase Microinverters.  Plan check is only for PV system, NOT for service upgrade or de-rating of main breaker.(((changes to approved set of plans. new service interconnection. ))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
80	19041-20002-06153	10236 W MOSSY ROCK CIR	90077	5	156B153   196	4382025***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.12205	-118.44372	plan check only, supplemental for changes to approved set. minor changes to single line diagram and site plan. clouded changes only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
81	18041-20000-07774	20654 W CHESTNUT CIR (#338)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.29351	-118.58462	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
82	13041-10000-12800	237 E WAYLAND ST	90042	1	153A231    16	5484031017	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.1157	-118.18759	PV1.  Install roof-mounted solar array, interconnect with main panel.  System size: 3.68 KW.  {Transformerless inverter: SolarEdge SE3800A-US}  {15 modules: TSM-245PA05}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
83	15041-10000-11011	444 S SAN VICENTE BLVD 6th Floor	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.07021	-118.37547	TI TO AN (E) MEDICAL BUILDING, IN THE 6TH FLOOR. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
84	15041-20000-11991	9509 N JELLICO AVE	91325	12	201B129   442	2755005005	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Expired	06/06/2017 12:00:00 AM	ADDRESS	34.24348	-118.51908	PV1. Install roof mounted PV system sized 8.8 kW. Interconnected with main service panel. (44) Kyocera KU260-6 modules(1) Solaredge SE 3800(1) Solaredge SE 5000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
85	13041-10000-20495	11737 W PICO BLVD	90064	11	123B149   693	4260029029	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			Corrections Issued	08/01/2013 12:00:00 AM	ADDRESS	34.03136	-118.44658	Interior tenant improvement for Blue Pooch Dog Grooming.  Title 24 plan check as per inspector's request in conjunction with express permit no. 13041-30000-19181.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
86	16041-10000-37829	6275 N PENFIELD AVE	91367	3	177B113   341	2153036013	RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2016 12:00:00 AM			Verifications in Progress	01/06/2017 12:00:00 AM	ADDRESS	34.18499	-118.56776	PV FOR PV SYSTEM 6.8KW AC USING BATTERY BACKUP SYSTEM. SYSTEM CONTAINS 24 modules. central inverter with built in charge controller. system uses 12 batteries to supply 48v DC. system includes installation of back up load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
87	17041-10006-37515	1400 N CAHUENGA BLVD	90028	13	147A187   280	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM			PC Approved	07/09/2019 12:00:00 AM	ADDRESS	34.09641	-118.32933	07/09/2019Changes to an approved set of plans. Note changes under 15, scope of work includes the addition of air fans to guestrooms on previously approved circuits. _______________________________________________________FULL PC FOR POWER AND ENERGY. NEW 8 STORY HOTEL WITH RESTAURANT AT GROUND FLOOR (CORE&SHELL ONLY) AND TOP LEVEL AMENITY WITH THREE SUBTERRANEAN GARAGE BASEMENTS.  SCOPE INCLUDES A NEW 2500A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 27,500 SQ. FT. B#16010-10000-05898	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
88	13041-20000-24122	13347 W OXNARD ST	91401	2	177B157   818	2330022008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.17967	-118.42427	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3KW AC USING 15 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
89	13041-10000-30878	1600 S HOOVER ST	90006	1	127-5A201 204	5135009028	CM-1	Central	Westlake	Pico Union		2243.10	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.04344	-118.28395	PLAN CHECK FOR T24 ENERGY ONLY. SUBWAY RESTAURANT. 1 STORY BUILDING. 906 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
90	17041-10000-23755	7301 N MEDICAL CENTER DR	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.20262	-118.62963	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 86000 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
91	12041-10000-05322	6600 N TOPANGA CANYON BLVD #2092	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T 24 Energy and Emergency Lighting only. Existing Apple Store. Suite #2092. Adding 9 new lights and rearranging 15 circuits. 654 sqft.Permit for 1 new branch circuit for Variable Volume Damper. Additional 14 outlets, 10 existing light fixtures, 2 new light fixtures on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
92	19041-10000-31137	3035 E ISABEL DR	90065	1	148-5A217  96	5455002025	R2-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.10258	-118.2336	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM WITH ESS CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 21 MODULES USING P400 OPTIMIZERS AND TESLA POWERWALL. MAIN BREAKER DERATING SHALL BE PULLED UNDER DIFFERENT PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
93	18041-10000-28121	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.06371	-118.2982	Install new Fire Alarm System Core and shell/Change of use from residential studio to office. Building is historical. (1) FACP, (115) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
94	17041-10000-24713	20920 W VICTORY BLVD	91367	3	180B109   587	2149003029	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.18815	-118.58943	PC for T24 only, replace existing indoor fixtures with LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
95	18041-10000-13530	1660 S PERRINO PL	90023	14	118-5A219  12	5169015***	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.01871	-118.2213	REMOVE OUTDOOR HID FIXTURE AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
96	17041-20000-45630	9011-9079 N WOODMAN AVE	91331	6	195B153   276	2639033005	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Issued	03/19/2018 12:00:00 AM	ADDRESS	34.23318	-118.43921	permit fee $0.00 by state senate bill no.1222Plan check for feed-in-tariff solar pv system. Roof mounted arrays on multiple buildings.439.6kW ungrounded system. (12) 33.3kW inverters. (2) 20kW inverters.(1,518) 340W pv modules. (759) 700W power optimizers.(N) 800A 277/480V 3ph 4w service for FIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
97	16041-10000-36720	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.0365	-118.3687	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERICLA BUILDING. SCOPE INCLUDES 178 FA DEVICES, 3 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
98	17041-30000-02372	6648 N CLEON AVE	91606	2	180B173   274	2414026003	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.19169	-118.36799	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
99	13041-10000-02650	517 N SAN PASCUAL AVE	90042	14	154-5A235 247	5716028017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.04	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.11686	-118.17448	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. PV1 SYSTEM TOTAL SIZE 3.672 KW. TOTAL OF 17 UNITS. MICROINVERTER ENPHASE M215-60-2LL-S22. SOLAR PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
100	15041-10002-12267	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM			PC Approved	01/19/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	*** Supplemental to approved set of plan: Connect O.S. to the controlled receptacles, added table of lighting devices model number. **CHANGES TO APPROVED SET OF PLANS. SET CONTROLLED RECEPTACLES TO LOCAL TIME CLOCK. LIGHITNG CONTROLLED THROUGH OCCUPANCY SENSORS, NO ROOM CONTROLLER. NO OTHER CHANGES. POWER DENSITY REMAINS.*PC FOR ENERGY. TI FOR OFFICE TER 3 OF LAX. TOTAL AREA 635 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
101	16041-10000-02239	231 E 12TH ST	90015	14	124-5A209  66	5145021028	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.03655	-118.25752	T-24, CHANGE OF USE FROM RETAIL TO COFFEE SHOP. SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTACLES. TOTAL SQ. FT. 988	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
102	18041-20002-43866	3301 N LONGRIDGE TER	91423	4	159B161   304	2385010001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.13006	-118.41882	Revision to approved plans.  Change of PV interconnection details.  200A main on 400A rated bus section.  $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.(((pv1install roof mounted pv system sized 11.2KW AC interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
103	18041-10000-41964	19603 S VERMONT AVE	90502	15	057B197    32	7351034024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	33.85256	-118.29073	PLAN CHECK FOR T24 ONLY FOR TENANT IMPROVEMENTS IN (E) TO AUTO REPAIR TO EXPAND OFFICE SPACE, NO CHANGE OF USE. INSTALL NEW FEEDER TO NEW 75 KVA TRANSFORMER AND NEW 200A PANEL. TOTAL AREA 2,370 SQ.FT(B# 18016-10000-35503)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
104	18041-10000-07981	1000 W TEMPLE ST	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	02/18/2020 12:00:00 AM		Issued	02/18/2020 12:00:00 AM	ADDRESS	34.06171	-118.25046	PC FOR METHANE MITIGATION SYSTEM LEVEL 5. GAS DETECTION PROVIDED. TOTAL OF 120 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
105	17041-20001-24364	8828 N CANBY AVE	91325	12	195B125   474	2769026006	R2-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.23156	-118.53466	expeditepv1install roof mounted pv system sized 4.5kw intercomnnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
106	14041-20001-32673	16801 W MOONCREST DR	91436	5	165B133   338	2291010010	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.14766	-118.49899	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating the main to 175A.System size: 8.64kW. Ungrounded system.36 EnPhase M250 microinverters with 36 275W pv modules across 3 strings (12+12+12).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
107	16041-10000-45852	10948 W MCBROOM ST	91040	7	207B173    92	2542001010	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Issued	12/30/2016 12:00:00 AM	ADDRESS	34.26119	-118.36894	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(12)MODULES-EOPLLY  156MB/72(1)INVERTER-SMA SUNNY BOY 3000US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
108	19041-10000-28430	13574 W FOOTHILL BLVD bldg-2	91342	7	222B157   200	2513006900	RD1.5-1XL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			07/24/2019 12:00:00 AM			PC Approved	08/19/2019 12:00:00 AM	ADDRESS	34.30647	-118.42954	Plan check only. DELTA 3 CHANGES TO AN APPROVED SET. CHANGES TO FIXTURES SCHEDULE, WATTAGE AND TYPES. CHANGES ALSO INCLUDE DECREASING THE HORSE POWER OF THE ELEVATOR, UPDATES TO PHOTOMETRICS, LOAD CALCULATIONS AND T-24. Permit pulled under 18041-20000-39767 & 18041-20000-39770Original scope:New 3-story 27-affordable units apartment.  Scope of this permit is building 2 out of 2 apartment buildings on site.  1600A, 208Y/120V 3ph-4w service (located in Building 1) supplying both buildings 1 and 2 (single feeder).Building permit under 18010-10000-04405.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
109	19041-20000-00947	1140 N CITRUS AVE	90038	4	144B185   564	5532019018	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Info Complete	01/09/2019 12:00:00 AM	ADDRESS	34.09188	-118.33969	Plan check for Title 24 only in existing space, studio and office Tenant Improvement. Total area: 15000 sq ft. B#18016-10000-12663	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
110	10041-20000-25061	2100 N LIVE OAK DR EAST	90068	4	151-5A193 211	5587025001	RE11-1D	Central	Hollywood	Greater Griffith Park, Hollywood United	YES	1893.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.10891	-118.3093	T.I. to existing building.  Install general/emergency lighting in lobby area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
111	19041-10001-44047	24321 W WELBY WAY	91307	12	183B089   712	2034004011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.19394	-118.65452	PLAN CHECK ONLY. PERMIT FEES ARE PAID UNDER MASTER APPLICATION. PLAN RESTAMP TO REPLACE LOST APPROVED SET. SCOPE ALSO INCLUDE UPDATING THE INFORMATION ON THE PLAN TO SHOW NEW 125A SERVICE PANEL. PANEL REPLACEMENT IS PERMITTED SEPARATELY.  Original scope: PLAN CHECK FOR A PV1 SOLAR SYSTEM. SYSTEM SIZE 9.12KWdc(6000Wac) using 32 Q.ANTUM  BFR-G4.1 285 MODULEWS, 32 SOLAREDGE P320 POWER OPTIMIZERS, AND 1 SOLAR EDGE SE6000H-US INVERTER. CONNECTED TO AN EXISTING 125AMP SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
112	16041-10000-18605	355 S GRAND AVE STE-4200	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.05191	-118.2525	PC FOR ENERGY. TI - INTERIOR REMODEL OF LEVEL 42.  NO CHANGE IN USE OR PARKING. TOTAL AREA 14817 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
113	19041-20000-02850	990 N HILL ST	90012	1	136-5A215 169	5414007028	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Issued	02/28/2019 12:00:00 AM	ADDRESS	34.06691	-118.23727	T24 ONLY PC FOR EXISTING COMMERCIAL SPACE, TOTAL SQFT'G = 12593	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
114	19041-10000-19997	5901 W CENTURY BLVD 1530	90045	11	090B169    15	4124030042	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE TOTAL AFFECTED AREA 1990 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
115	13041-10002-35328	21650 W OXNARD ST flrs 2,7 8	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Expired	11/09/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	((10/15/2014- CHANGES MADE TO APPROVED SET. ADDED SOME LOAD AND INCREASED SIZE OF TRANSFORMER AND FEEDER. TOTAL LOAD ON 112.5KVA TRANSFORMER IS 105.6KVA PER CALCULATIONS PERFORMED.)) PC FOR POWER AND ENERGY. NEW LIGHTING IN SMALL STORAGE CLOSET. POWE RFOR EXISTING EQUIPMENT BEING REFED WITH NEW WIRING AND TRANSFORMERS. NEW WIRING WITH LOAD GREATER THAN 400A. NEW FEEDERS CHARGED AS PANEL BOARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
116	18041-30000-14438	905 S LE DOUX ROAD	90035	5	132B173   177	4333022041	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.06069	-118.37752	Plan check for a fire alarm system for a 5-story, 21-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (77) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
117	18041-20000-08474	13343 W ARMINTA ST	91605	2	189B157   601	2301017031	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.21353	-118.42422	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac/10.4 kWdc and consists of (1) inverter and (32) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
118	14041-20001-16364	2500-2502 W SUNSET BLVD	90026	13	141A205   320	5402014023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	34.07943	-118.26921	12.23.2014 - Plan check for energy only (requested by inspector). Check lighting system for beauty salon and market units. 2008 Title 24 standards due to permit being pulled prior to July 1st, 2014. 2,642sqft.[REWIRE FIRE DAMAGED UNITS]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
119	18041-10000-21855	2029 S CENTURY PARK EAST STE 2400	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Energy plan check for an office T.I located in the 24th floor of a highrise building; Scope inclues a new lighting system and equipment with a total Title 24 area is 23974 -SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
120	19041-10000-48206	2352 N RONDA VISTA DR	90027	4	150B201  1222	5433010014	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM			Reviewed by Supervisor	12/09/2019 12:00:00 AM	ADDRESS	34.10451	-118.27624	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION WITH AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 1 CENTRAL INVERTER (SE7600H), 24 MODULES (Q.PEAK DUO BLK-G5/SC 315), 24 OPTIMIZERS (P400), 1 ENERGY STORAGE SYSTEM, AND 1 PANEL OF 200 AMPS.SYSTEM SIZE: 7.56 KW DC, 7.6 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
121	18041-20000-26955	12020 W CHANDLER BLVD 2nd Floor	91607	2	171B165   117	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.16825	-118.39512	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 552 sq. ft.Note: Building application has been generated under 18016-10000-19224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
122	16041-10000-30349	11019 W PENROSE ST	91352	6	195B173   312	2408027024	[T][Q]M1-1-CUGU, [T][Q]P-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.2296	-118.37117	PC FOR POWER. SERVICE UPGRADE FROM 400A TO 800A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
123	14041-10001-03745	457 N FAIRFAX AVE	90048	5	141B177  1210	5527031015	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	PIN	34.07986856	-118.361786	((((6/26/14  -  Plan check only.  Permit has been pulled on master application.  Original approved set lost.  Minimum plan check fee only.)))))plan check for t24 enrgy. remodel lighting system in existing coffee shop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
124	19041-10000-47801	9245 N WOODLEY AVE	91343	12	198B141   491	2676014024	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	04/18/2020 12:00:00 AM	ADDRESS	34.23882	-118.48523	[EPLAN] INSTALLATION OF NEW ESS (TESLA POWERWALL) TO AN EXISTING PV1 SYSTEM.CONNECTED TO AN EXISTING 200A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
125	19041-20002-42740	283 N TRINO WAY	90272	11	126B121   503	4415030011	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.04125	-118.5445	EXPEDITED PER CUSTOMER REQUESTPV1. INSTALL 15.360 KW DC PV SYSTEM WITH (48) MODULES/ENPHASE MICROINVERTERS AND (2) TESLA POWERWALL BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
126	19041-20000-06260	1403 N WILMINGTON BLVD	90744	15	036B201   762	7414024029	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	33.79069	-118.27518	T24 PLAN CHECK FOR ENERGY ONLY, ADDITION OF LIGHTS AND OUTLETS TO EXISTING COMMERCIAL SPACE, TOTAL SQUARE FOOTAGE = 271 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
127	12041-10000-04240	6927 N LINDLEY AVE	91335	3	183B125   741	2125027020	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	03/23/2012 12:00:00 AM	ADDRESS	34.1964	-118.52754	New roof mounted 7.68 kw solar system for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
128	14041-20000-34902	15709 W DEVONSHIRE ST	91344	12	204B141   323	2661014008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.2575	-118.47427	PV1Install a roof-mounted solar array on SFD and detached garage. Interconnect with a 200A MSP.System size: 4.56kW. Ungrounded system.19  275W pv modules across two strings (10+9).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
129	14041-20000-35674	12712 N WOODCOCK AVE	91342	7	222B149  1058	2507001020	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.30128	-118.44928	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service pannel.(12) Sunpower E20/327 Panels(1) Power One PVI 3.8 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
130	14041-10000-16717	11100 W SANTA MONICA BLVD SUITE 100	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLAN CHECK FOR ENERGY ONLY FOR EXISTING HIGHRISE TI. SCOPE OF WORK IS ON THE GROUND FLOOR SUITE 100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
131	14041-20000-31442	8549 N NEWCASTLE AVE	91325	12	192B125   114	2787003010	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.22615	-118.52605	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size: 3.8kW. Ungrounded system.16  245W pv modules across two strings (8+8).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
132	18041-10000-26120	725 S FIGUEROA ST 26TH FLR	90017	14	129A207   336	5144009093	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	TI IN AN EXISTING OFFICE AREAON 26TH FLOOR. T-24 ENERGY ONLY.BLDG PERMIT # 18016-10000-21200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
133	10041-10000-19124	10984 W STRATHMORE DR 1-8	90024	5	135B149   422	4363008007	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Public Safety Only			09/27/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.06595	-118.45005	NEW FIRE WARNING SYSTEM FOR A 10-UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
134	15041-10000-40345	704 W Q ST	90744	15	036B205   545	7414031016	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	33.79483	-118.27149	PV1 SFD. TOTAL SYSTEM SIZE 3KW AC USING SINGLE TRANSFORMERLESS INVERTER. USING 9 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
135	10041-10000-24581	12925 N BRADLEY AVE	91342	7	222B145   472	2506003017	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.30432	-118.45895	New PV system. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
136	17041-10000-14084	17238 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.20823	-118.50858	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 1440 SQ. FT. TOTAL OF 10 FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
137	19041-10000-04281	604 W C ST	90744	15	027B205   232	7417019921	OS-1-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.77218	-118.26861	PC FOR REPLACING (1) OBSOLETE METHANE SYSTEM MONITORING PANEL WITH NEW MODEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
138	18041-10000-46293	1700 S STEARNS DR	90035	10	129B173  1412	5066013018	R1R3-RG	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.04626	-118.37261	PLAN CHECK FOR A ROOF MOUNTED 3.8KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER WITH 17 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
139	19041-10000-03671	1000 N NORMAN PL	90049	11	141B141   281	4429010001	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.0794	-118.47844	NEW TWO STORY 12,800 sqr ft SINGLE FAMILY DWELLING WITH BASEMENT, ATTACHED SIX CAR GARAGE WITH 600 AMP SERVICE. PLAN CHECK ONLY. PERMIT WAS ISSUED: 15010-20000-04319	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
140	13041-10000-21089	528 W 121ST ST	90044	15	084B201  1343	6117005005	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	33.92239	-118.28407	PV1 5.88KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: powerone PVI-5000-OUTD-US-Z] [(24) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
141	19041-10000-04300	15355 W MORRISON ST	91403	4	171A145   149	2263039002	(Q)CR-1-RIO, (Q)P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.16089	-118.46827	PLAN CHECK FOR ROOF MOUNTEFD 18KVA PV SYSTEM CONSISTING OF 2 CENTRAL INVERTER(SE9KUS) WITH 68 MODULES USING P730 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
142	16041-20000-07271	11550 N INDIAN HILLS ROAD #160	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.27998	-118.45874	PLANCHECK FOR POWER.  TENANT IMPROVEMENT IN HOSPITAL . NOT OSHPD3. T24 EXEMPT PER APPLICANT DUE TO I.2 OCCUPANCY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
143	15041-10000-05761	956 S SAN PEDRO ST	90021	14	124-5A211  90	5132001021	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	PIN	34.0361994	-118.25098181	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 930.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
144	18041-10001-27446	10161 N HILLHAVEN AVE	91042	7	204B197   964	2565013037	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM			Reviewed by Supervisor	07/31/2018 12:00:00 AM	ADDRESS	34.25403	-118.28995	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
145	11041-20000-14589	6327 W HOLLYWOOD BLVD	90028	13	148-5A187 151	5546004012	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	07/13/2011 12:00:00 AM	ADDRESS	34.10178	-118.32776	FIRE ALARM SYSTEM INSPECTION REQUIRED PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
146	14041-20000-06646	4553 N WILLIS AVE 1-20	91403	4	168A149   178	2264017035	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.15368	-118.45537	Roof mounted PV system with system size of 33KWdc (System Size need to be verified) .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
147	16041-10001-16852	15510 W LEMARSH ST	91345	7	204B145   552	2660003040	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.25536	-118.46998	**Fee ExpeditePV1, rooftop solar installation 13.6 kW AC.  (46) SPR327NE       (1) SB6000TL-US   (2) SB3800TL-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
148	13041-20000-20891	523 W 5TH ST 8TH FLR	90731	15	015B197   206	7451028032	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	33.73954	-118.28856	RENOVATION OF OFFICE SPACE. NEW CONFERENCE ROOM. DAYLIGHT AREA. TOTAL AREA 1100 SQFT. WORK DONE ON 8TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
149	19041-10000-38639	14832 W RAYMER ST	91405	6	189B149   531	2210025900	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	06/24/2021 12:00:00 AM	ADDRESS	34.21286	-118.45635	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 19 FA DEVICES AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
150	11041-20000-13757	1515 N VERMONT AVE 6th Flr	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01, 1913.00	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.09867	-118.29207	TI: convert (e) files room to (n) Ophthalmology. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
151	16041-20000-23917	14358 W MAGNOLIA BLVD 1-95	91423	4	171A151    50	2248009025	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.16469	-118.44621	PV2.  Install 55.8 kW DC roof-mounted PV system.  (180) modules with (4) 11kW transformerless central inverters.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
152	15041-10002-01358	200 WORLD WAY TERM 2-DEPT LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/31/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Change to approved set by down sizing the main breaker for panel UNV from 200-Amp to 100-Amp. All load and feeder remain the same. all changes under delta-2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
153	18041-10000-08049	3200 S HOOPER AVE	90011	9	117A211   280	5114039019	MR1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.01408	-118.25203	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 222600 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
154	15041-10000-39714	10901 W CHALON ROAD	90077	5	141B149    34	4369028003	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM			PC Info Complete	12/01/2016 12:00:00 AM	ADDRESS	34.08571	-118.45489	2 STORY SINGLE FAMILY DWELLING W/ ATTACHED GARAGE. 120/240 1P3W 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
155	10041-10000-25244	1248 S FIGUEROA ST 1ST FL	90015	9	126A205    19	5138025014	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.04096	-118.2674	TENANT IMPROVEMENT OF EXISTING SHELL SPACE. (HOOTER RESTAURANT, 6258 SQ FT).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
156	13041-10000-30910	4816 S 6TH AVE	90043	8	111B189  1012	5014018004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	33.99949	-118.32345	V1, Install 1.96 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: AURORA PV1-3.0-OUTD-S-US. 8 modules Yingli Yl245P-29B.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
157	19041-10001-30418	10250 W SANTA MONICA BLVD FC-7	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	CHANGES TO AN APPROVED SET OF PLANS FOR AN EXISTING TAKE-OUT RESTAURANT. CHANGES INCLUDE A REDESIGN OF ELECTRICAL PLANS AND CHANGE OF ENGINEER OF RECORD.NOTE: PC ONLY. PERMIT FEES ARE PAID UNDER MASTER APPLICATION 19041-10000-30418	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
158	11041-10000-06841	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM			PC Approved	05/11/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I.  EXISTING RETAIL SPACE.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
159	17041-10000-05276	407 E FLORENCE AVE	90003	9	102B205   778	6011008031	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	33.97489	-118.26713	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 8,700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
160	11041-20000-19205	8128 W 3RD ST	90048	5	138B173   957	5511029018	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	09/09/2011 12:00:00 AM	ADDRESS	34.07213	-118.36689	Retail t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
161	19041-20000-04939	6209 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.18338	-118.60617	Plan check for Title 24 only in existing space Tenant improvement. Total area: 3740 sq ft. Total load is less than 400AB#18016-20000-41241	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
162	12041-20000-20613	330 E WASHINGTON BLVD B	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			PC Approved	08/30/2012 12:00:00 AM	ADDRESS	33.98065	-118.46362	T-24 for remodeled space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
163	13041-10000-26106	380 WORLD WAY #T37-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of led sel-illuminated signs on the external walls of a the tenant space Emporio Armani on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
164	17041-10000-00840	1102 W D ST BLDG 12-LOT 8	90744	15	027B201   403	7417010919	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM				PC for a new fira alarm system. Scope includes 45 fire alarm devices and 2 fire alarm panels for an existing apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
165	19041-10000-53317	700 N ALAMEDA ST	90012	14	132A215   180	5409023930	ADP-RIO	Central	Central City North	Historic Cultural North		2060.20	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			Reviewed by Supervisor	01/08/2020 12:00:00 AM	ADDRESS	34.05488	-118.23748	T-24 ENERGY PC ONLY. TOTAL AFFECTED AREA 3490sqft. SCOPE OF WORK INCLUDES INSTALLATION OF NEW PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
166	17041-10000-28681	1848 E MARENGO ST	90033	14	132A223    19	5201017052	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.05773	-118.21052	REMOVE HID FIXTURES AND RELACE WITH NEW LED FIXTURES- T/24 ONLY. TOTAL SQ FT 9900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
167	15041-10000-32809	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	TI on the (E) office for high rise build., 40th, 41st, and 42nd floor. PC for Power and Energy. Addition (3) New panels, and (1) xformer 75KVA. Total indoor/outdoor area: 43700 sq.ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
168	14041-10000-11204	8520 S BROADWAY 2ND FL.	90003	9	097-5A203 256	6040009027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	33.96097	-118.27809	ELECTRICAL PERMIT HAS PULLED PER APPLICANT REQUEST.plan check for energy only. Scope of work does not include patient care areas per applicant. Changes on plan include: scope of work and clouds that indicate areas that are being worked on as part of this project.  BLDG#:14016-10-04610 - TENANT IMPROVEMENT OF EXISTING MEDICAL OFFICE LOCATED ON 2ND FLR ONLY. see 14041-10-08198 for 10kva UPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
169	19041-20000-50573	22120 W PROVIDENCIA ST	91364	3	168B101   404	2170011026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Issued	12/09/2019 12:00:00 AM	ADDRESS	34.15752	-118.60865	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 11.34/10.31 KW AC CEC. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS AND A 10 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
170	18041-20001-45694	1201 N EL CENTRO AVE	90038	13	144B189   323	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Apartment			11/30/2018 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.09274	-118.32458	Expedite per applicant request Plan check for PV roof mounted system, system size: 76.3kW with 218 PV Modules and 6 inverters(11.4kW)PV Modules are mounted on 3 separate buildings, Supply side connection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
171	17041-10000-25342	1648 N KINGSLEY DR	90027	13	148-5A195 129	5544015010	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM			Reviewed by Supervisor	08/23/2017 12:00:00 AM	ADDRESS	34.10129	-118.30303	Plan check for PV roof mounted system. System size: 18kWac with 70 moduels and 2 inverters(5.2kW) and 1  inverter(7.6kW) conncted to MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
172	19041-20004-00997	20851-20853 N SHERMAN WAY	91306	3	183B109    62	2113013038	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Issued	08/14/2019 12:00:00 AM	PIN	34.20136408	-118.5880133	Revision to approved plans.  Change of circuiting, additional subpanels to address disaggregation compliance. (((Fire-damaged building and tenant improvements. Plan check for power and energy. Total area: 5250 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
173	19041-20000-18444	15303 W VENTURA BLVD 1070	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	T24 ONLY PLAN CHECK FOR TI TO EXISTING OFFICE HIGH RISE 10TH FLOOR SUITE 1070. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1,610SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
174	14041-20000-02287	17445 W CHASE ST	91325	12	192B129   158	2787022007	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Expired	03/22/2016 12:00:00 AM	ADDRESS	34.2237	-118.51409	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
175	13041-10000-33846	1300 W 177TH ST BLDG F	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.87031	-118.29542	"PLAN CHECK FOR POWER AND ENERGY FOR 90 APARTMENT UNITS , BUILDINGS A-F;  THIS APPLICATION IS FOR BUILDING ""F"", WHICH IS A MULTI-PURPOSE BUILDING. PROJECTED AREA FOR LIGHTING WORK INCLUDES BOTH INDOOR AND OUTDOOR, TOTALING TO 3957 SQ FT. NOTE: SERVICE & SWB SECTIONS WERE CHARGED ON BUILDING ""E"" FROM PC# 13041-10000-33845"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
176	13041-10000-35544	4124 W 59TH PL	90043	8	105B181   432	4003005007	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	33.98607	-118.34735	PV1, Install 3 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (12) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
177	19041-20000-16346	16911 W VENTURA BLVD	91316	5	168B133   103	2258018004	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM			Corrections Issued	05/02/2019 12:00:00 AM	ADDRESS	34.15959	-118.50159	New 400A 240/120V 3ph-4w delta service to (E) commercial building.  Plan check for Title 24 for new outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
178	14041-20000-12448	12133 N BELLANDO CT	91344	12	219B125    98	2601073023	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.29444	-118.52582	PV1 ROOF MOUNTED SOLAR SYSEM 8.32KW INTERCONNECT WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS MODEL #PVI-3.0-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
179	19041-10001-36296	9816 W LA CANADA WAY	91040	7	207B181   208	2549024011	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.26189	-118.34584	Expedite per applicant request.(((Plan check for a PV1 14.4KW AC / 18.3KW DC roofmounted system. Scope includes (1) subpanel, (2) inverters, (62) modules and optimizers interconnecting through the service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
180	17041-10000-34351	8255 W BEVERLY BLVD	90048	5	138B173   390	5514009055	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.07623	-118.36921	Plan check for T24 only, TI on an existing office, panel is existing just add few circuitry.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
181	18041-20000-35779	14848 W DELANO ST	91411	6	178-5A149 247	2241017010	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			09/19/2018 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	10/14/2021 12:00:00 AM	ADDRESS	34.18247	-118.45695	Plan check for new multi-family building 11 units 3 story. Total area: 8275 sq ft. B#18010-20000-01788	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
182	11041-10000-15043	10250 W CONSTELLATION BLVD	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI IMPROVEMENT TO EXISTING HIGH-RISE OFFICE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
183	19041-20000-30966	24637 W GARDENSTONE LANE	91307	12	183B085    15	2031004071	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.2016	-118.66055	Plan check for PV roof mounted with battery back up system, PV system sizea: 6.3KW with 1 inverter(7.6KW) and 20 PV Modules, Tesla Battery PowerWall 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
184	14041-10000-14003	127 E 6TH ST	90014	14	127-5A211  38	5148020007	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.04488	-118.24911	T24 ONLY, TOTAL AREA 790 SQ FT. RETAIL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
185	19041-10000-34352	5719 S MESMER AVE	90230	11	105B165   424	4220014044	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	05/07/2020 12:00:00 AM		Permit Finaled	03/02/2022 12:00:00 AM	ADDRESS	33.98439	-118.3997	FULL PC FOR POWER AND ENEGRY (PER APPLICANT REQUEST) (BLDG ?), SCOPE OF WORK INCLUDES A NEW 400A DISTRIBUTION BOARD BEING FED BY AN EXISITNG 800A SWITCHBOARD, SERVICE IS EXISTING AS WELL. THE NEW DISTRIBUTION BOARD FEEDS A NEW ELEVATOR, THREE EV CHARGERS, MECHANICAL EQUIPMENT AND TWO NEW SUBPANELS. TOTAL AFFECTED AREA IS 5517 SQFT.B#: 19014-10000-02190	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
186	13041-10000-05388	8611 S WESTERN AVE	90047	8	097-5A193 352	6036011001	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	33.95949	-118.30921	13041-10000-05388DEMOLITION removed all the lights so they are reinstalling it. SHELL TRAINING CENTER. TENANT IMPROVEMENT (7,645 sq ft) - NEW  T-BAR CEILING TILES, CARPET AND PAINT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
187	11041-10001-11482	11900 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	03/15/2012 12:00:00 AM	ADDRESS	34.28642	-118.50125	SUPPL. APPLICATION FOR THE 2500 AMP SERVICE TO FEED 4 TENANTS OF THE BUILDING.NEW SERVICE AND COMPLETELY NEW ELECTRICAL SYSTEM FOR AN EXISTING GROCERY STORE BUILDING.  CUSTOMER WILL BRING IN MISSING T-24 SHEETS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
188	17041-20000-35099	1946 N HILLHURST AVE	90027	4	150B201   791	5590011010	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Issued	10/02/2017 12:00:00 AM	ADDRESS	34.10665	-118.28725	Tenant improvement/change of use of (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
189	19041-20000-26144	7850 N SAUSALITO AVE	91304	12	189B101   532	2013013012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.21339	-118.61555	PV1 PLAN CHECK FOR ROOFTOP MOUNTED PV SYSTEM. SYSTEM SIZE IS 9.135KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (29) HANWHA Q CELL PV MODULES WITH A SOLIS-1P7.6K-4G-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
190	16041-10000-34165	10250 W SANTA MONICA BLVD # 1855	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Madewell"" Ste. 1855.  Install 45kVA Xfrmf, new panels and its circuits, lights and receptacles. Total effected area: 2,556 sq.ft.*** New load 81A to DB-ELA41"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
191	19041-10000-48026	837 E COMMERCIAL ST	90012	14	130-5A217 198	5173019011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.05259	-118.22999	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS &REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY INDOOR/OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
192	18041-20000-40598	8500 N BALBOA BLVD Suite #170	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.22485	-118.50045	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. adding new lighting new controls and new equipment.  newly connected load >400 amps with equipment rated > 600 amps.Note: Building application has been generated under 18016-20000-32111.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
193	16041-10002-45433	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	DELTA CHANGES TO THE APPROVED TI PLANS. CHANGES INCLUDE NEW CIRCUITS, 3 NEW PANELS AND REVISION OF LIGHTING. NOTE CHANGES ON CLOUDED AREAS, DELTA22TI,TI,240,RFI1404R1,251,208,269 AND 250.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
194	14041-20003-05012	20522 W HAMLIN ST	91306	3	180B109   566	2148014010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.18901	-118.5806	(((5/5/2014- CHANGES MADE TO APPROVED SET. UPGRADING MAIN SERVICE TO 225A)))Changes from previously approved plans.  Changes include relocate modules on roof and remove AC disconnect.  Note: Permit is under the original application.  $00.00 Plan check fee due to Senate Bill from 2012.Previous Description:PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.2KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
195	12041-20001-12388	7370 W SUNSET BLVD	90046	4	147B181   654	5550021001	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.09785	-118.35128	Revision to previously approved plan on application numbers 11041-20000-23687 and 12041-20000-23687 to add a new restaurant.  New circuits, lighting, loads.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
196	12041-20000-14349	12103 W VENTURA BLVD	91604	2	162B165  1112	2367016013	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	09/07/2012 12:00:00 AM	ADDRESS	34.14369	-118.39571	energy plan check pizza rev	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
197	13041-20000-05853	21530 W CALIFA ST	91367	3	174B105    14	2146034151	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Apartment			03/06/2013 12:00:00 AM			Corrections Issued	06/24/2013 12:00:00 AM	ADDRESS	34.17705	-118.59939	New load to an existing 147-unit apartment building.  New load is greater than 400 amps per Engineer.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
198	15041-10002-01167	6944 S KNOWLTON PL	90045	11	102B173   375	4103013008	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	33.97371	-118.37115	CHANGES OF APPROVED SET OF PLANS. CHANGES UNDER DELTA 3 AS REFLECTED ON SINGLE LINE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
199	18041-10001-47149	13213 W ROSE AVE	90066	11	114B149   484	4244004024	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	01/04/2019 12:00:00 AM	ADDRESS	34.00899	-118.45386	EXPEDITED FEESPV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH AC COUPLED BATTERY STORAGE UNIT. (1) 7.6KW INVERTER AND (5KW) TESLA BATTERY. PV MODULES HAVE BEEN APPROVED AND FINALED IN THE PAST. TOTAL SYSTEM SIZE IS 7.6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
200	15041-20000-26152	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only replace lighting fixtures with LED in D level loading. Total indoor area: 31,000sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
201	14041-10000-17391	523 W 6TH ST Suite 1001	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Expired	08/04/2016 12:00:00 AM	PIN	34.04872199	-118.25441618	Title 24 plan check only.  Total area = 1,060 sq. ft.New lighting for existing commercial space.  No changes to power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
202	18041-20000-34978	12301 W WILSHIRE BLVD ste 405	90025	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.04271	-118.46948	ti to an existing commercial building (Dental Office).  adding new lighting new controls to a new panel, plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
203	19041-10000-36753	601 S FIGUEROA ST 22ND	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM			PC Info Complete	09/26/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Energy plan check for an office T.I located on the 22nd floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 19,157-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
204	14041-10000-34946	8820 N AMIGO AVE	91324	12	195B125   484	2770015037	[Q]MR1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.2315	-118.53845	Plan check for Energy only T-24. Total area: 3418 SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
205	19041-10000-10257	13278 N RALSTON AVE	91342	7	225B141   163	2501002041	[Q]MR1-1, [Q]P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.31318	-118.47314	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
206	15041-10001-27005	12700 W MILLENNIUM #48	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	33.97639	-118.41499	Expedite per applicant request.(((PV1 1.5KW roof-mounted system with (6) (SPR-X20-250 Sunpower modules interconnecting through a sub-panel. Application is  plan check only, permit fee is paid under 15041-90000-26264.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
207	11041-10000-07535	1640 S SEPULVEDA BLVD 440	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.04838	-118.44468	T.I.  SUITE NUMBER 440.  REPLACING LIGHTING FIXTURES.  TITLE 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
208	18041-20000-35977	6106 N LANKERSHIM BLVD	91606	2	177B169   518	2338005008	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.05	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.18158	-118.38448	ti to an existing commercial building.  adding new lighting new controls to a new panel.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
209	15041-10000-12631	2141 W ADAMS BLVD	90018	10	123B193   535	5058012022	R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.03286	-118.31288	Energy plan check for a meeting room (Pavilion)  located in a commercial building; scope includes replacing existing incandescent recessed fixture with LED down light at the same location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
210	14041-10000-02484	2106 W COLORADO BLVD	90041	14	162A223   122	5686003017	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.13896	-118.21232	PLANCHECK FOR T24 PER INSPECTORS REQUEST. TENANT IMPROVEMENT FOR MILKFARM. 1490 SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 14041-10000-01290	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
211	12041-10000-09572	20615 W MARTHA ST	91367	3	174B109   404	2151021038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.17229	-118.58264	Plan check 6.72KW roof mounted transformerless inverter type photovoltaic system with SolarEdge power optimizer. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
212	17041-20001-26310	2429 N LYRIC AVE	90027	4	150B201  1115	5433009005	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.10515	-118.27605	EXPEDITED PER APPLICANTS REQUEST27 KWY ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.93 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
213	14041-20000-31547	20519 W PESARO WAY	91326	12	210B109   394	2701050017	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.27556	-118.57977	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER NON STANDARD PLAN WITH POWER OPTOMIZERS. SYSTEM SIZE: 5 KW AC.[[[ 2 DIFFERENT SIZE OF MODULES]]] (25)  CANADIAN SOLAR C86P-235  AND C86P-250(1) SOLARD EDGE SE5000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
214	11041-10000-18528	363 N COPA DE ORO ROAD	90077	5	141B153   165	4362014001	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2011 12:00:00 AM	03/19/2012 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.08264	-118.44073	INTERIOR ALTERATIONS AND ADDITION TO EXISTING  SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
215	17041-20000-23031	15900 W HARVEST ST	91344	12	213B141   255	2666007010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.27797	-118.47825	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.35 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
216	18041-10000-25090	7261 W ESTEPA DR	91042	7	198B197    85	2562020015	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Issued	08/02/2018 12:00:00 AM	ADDRESS	34.2426	-118.29107	NOTE: FEES ARE REDUCED DUE TO SENATE BILL 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.19KWdc / 13.545KWac.(43) MODULES-PANASONIC GROUP VBHN330SA16(43) MICROINVERTERS-ENPHASE IQ7X-96-X-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
217	10041-20000-11371	14309 W BURBANK BLVD 101-105	91401	2	174B153   754	2245010051	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Apartment			06/15/2010 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.1723	-118.44467	Plan check power and energy for new for 8-unit apartment building with 2000A service.    <<<<<<<<Auto car lift on seperate application 10041-10001-11371>>>>>>>>>   Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
218	18041-20000-33976	150 N BERENDO ST	90004	13	138B197   679	5518027021	R3-1	Central	Wilshire	Wilshire Center-Koreatown		2112.02	Electrical	Electrical	Apartment			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.07425	-118.29398	Plan check for new fire alarm system for 4 story 21 units multi-family building. Total new fire alarm devices: 86 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
219	19041-10000-26819	777 S FIGUEROA ST Ste. #2600	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for energy only. Tenant improvement work on approximately 2614 SF of total floor area to expand suite #2600. New lighting and receptacles, existing panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
220	13041-10000-18149	10311 S WESTERN AVE	90047	8	091-5A193 265	6058007017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Apartment			07/10/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	33.94282	-118.30934	PV2.  Plan check for new installation of  29.61 KW(DC)  roof-mounted photovoltaic system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
221	13041-10000-32483	17986 W BORIS DR	91316	5	168B129   677	2184023012	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Expired	12/15/2015 12:00:00 AM	ADDRESS	34.15356	-118.52452	PV1. ROOF MOUNTED SOLAR ARRAY. NEGATIVELY GROUNDED SYSTEM. SYSTEM SIZE: 8100 WATTS DC. 1 STORY HOUSE. NON STANDARD PLAN.(30) SOLAR WORLD SW 270 (1) FRONIUS IG PLUS 7.5-1 UNI	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
222	19041-10000-04535	7600 S SEPULVEDA BLVD	90045	11	102B165   948	4106018001	[Q]C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	33.97143	-118.39468	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
223	14041-20000-12071	1680 N VINE ST SUITE 905	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	PC FOR T24 ENERGY ONLY. EXISTING OFFICES NEW LIGHTING. USING UNIT EQUIPMENT WITH MODIFICATION ON FILE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
224	19041-20000-07927	15301 W VENTURA BLVD ste 350	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.15411	-118.46654	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.  this is plan check only.  permit fees paid under application number 19041-90000-03219	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
225	15041-10000-02774	6842 N VALJEAN AVE	91406	6	183B141   689	2224025029	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.1951	-118.4857	Title 24 plan check only.  Total area = 7460 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
226	13041-20000-26989	13949 W TYLER ST	91342	7	228B153   119	2503019054	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.32399	-118.43802	New 8.06kw rooftop PV for an existing single family residence.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
227	17041-20000-05105	189 S THE GROVE DR Q-80	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	PLANCHECK FOR T24 ENERGY. T.I. to (e) retail space.  708 SQFT. SUITE Q-80	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
228	11041-10000-19328	3616 S TROUSDALE PKWY 4TH FL	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	11/07/2011 12:00:00 AM	ADDRESS	34.01983	-118.28534	REMODEL THE STORAGE ROOM INTO STORAGE AND OFFICE AT THE FOURTH FLOOR.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
229	10041-20000-05818	6702 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.11721	-118.33837	installing emergency lighting and exist sign in an apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
230	16041-10001-02240	825 S HILL ST	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			03/29/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/24/2021 12:00:00 AM	ADDRESS	34.04392	-118.25657	PC FOR REVISION TO APPROVED SET UNDER DELTA 1(SEE NOTE BELOW) REVISION TO LOBBY LEVEL, LEVEL 6 AND PENT HOUSE LIGHTING. SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTICALS. EXTRA  AFFECTED AREA IS 33682 SQ.FTTHE DESIGNER WILL MAKE FUTURE MARKS FOR DELTA 1 ON THE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
231	13041-10000-29605	3439 N CAHUENGA BLVD	90068	4	159B177   374	2425025008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Info Complete	10/23/2013 12:00:00 AM	ADDRESS	34.13204	-118.35319	Title 24 only, service is 400 amps.  T-24 for commercial office use.  Permit fees to cover panels and circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
232	16041-20001-41759	4047 N STANSBURY AVE	91423	4	162B153   110	2266012009	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	12/03/2016 12:00:00 AM	ADDRESS	34.14371	-118.44132	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP. Derating the main breaker to 175A. 11.4kW (7.6+3.8) ungrounded system. (40) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
233	15041-20000-42575	5135 N BLUEBELL AVE	91607	2	171B161   655	2357001003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	01/23/2016 12:00:00 AM	ADDRESS	34.164	-118.41064	Plan check for PV roof monted system. System size: 10.0kWac with 42 modules and 1 inverter(10.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
234	19041-10000-03655	6922 W HOLLYWOOD BLVD #101	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.10137	-118.34103	PC FOR ENERGY ONLY. CHANGES TO PERMANENT STORE FOR LINE FRIENDS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN EXISTING SPACE. TOTA SQ. FT. 7874.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
235	11041-20000-15300	8628 N VAN NUYS BLVD Suite #205	91402	7	195B149   735	2638001057	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.22682	-118.44957	Plan check power and energy for change of use to dental office on 2nd floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
236	15041-20001-18073	1014 E MANCHESTER AVE	90002	9	097-5A209 264	6042023030	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	PIN	33.9598697	-118.25710367	10/27/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Scope of work has been reduced to core and shell for (12) of (15) tenant spaces and tenant improvements to the remaining (3) of (15) tenant spaces. *****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes a new 2000-amp service, the installation of (16) panels, associated loads, a total indoor lighting area of 18,560 sq. ft. and an outdoor lighting area of 31,491. Note: Building permit is under application number 15016 - 10000 - 01400CHANGE OF USE  FROM AN EXISTING RETAIL, OFFICE, WAREHOUSE BUILDING TO 6 RETAIL SPACES AND 3 OFFICE/WAREHOUSE SPACES.  REMODELING IN AND OUTSIDE OF BLDG CHANGE FRONT ELEVATION; TENANT IMPROVEMENT AT 1 STORY RETAIL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
237	10041-20000-03762	1068 N SANBORN AVE	90029	13	145-5A201 414	5427007019	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM			PC Approved	03/03/2010 12:00:00 AM	ADDRESS	34.0919	-118.28058	parking both & exterior lighting t.i.Energyexisting permit 10041-90000-02689	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
238	14041-10001-23778	16860 W BOSQUE DR	91436	5	165B133   219	2291003008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.14999	-118.50019	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
239	12041-10000-23254	11927 W MONTANA AVE	90049	11	129B145  1149	4265007036	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	09/28/2012 12:00:00 AM	ADDRESS	34.05209	-118.47091	Title 24 , one story, storage room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
240	11041-10000-00785	1230 W 3RD ST	90017	1	132A209    97	5152014037	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.057	-118.259	PERMIT FOR COMM AND SECURITY SYSTEM, RELOCATE 10 EXISTING FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
241	14041-10000-06279	2800 W BEVERLY BLVD	90057	13	138A203   482	5155014021	C2-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM			PC Approved	03/07/2014 12:00:00 AM	ADDRESS	34.07025	-118.27894	"Title 24 for an existing bldg, lighting for bath room storages and corridoor., one story building.""COMPLY WITH DEPARTMENT ORDER effective date12/23/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
242	12041-10000-30407	10261 N GLENOAKS BLVD	91331	7	204B165   134	2537017065	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.25646	-118.39487	New 113 KW roof mounted PV system for a storage facility.   Also install new 1000A and 800A subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
243	12041-10000-05052	12100 W OLYMPIC BLVD 1ST FLOOR	90064	11	123B149   575	4259025010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	ADDRESS	34.03215	-118.45396	TENANT IMPROVEMENT PORTION OF EXISTING HEALTH CLUB ON 1ST FLOOR : REMODEL RECEPTION AREA AND EXERCISE AREA, REMOVE UNAPPROVED JUICE BAR, NEW LOUNGE AREA, NEW INTERIOR NON-BEARING WALLS, MILLWORKS AND FINISHES. NO CHANGE IN FLOOR AREA.PLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
244	14041-10000-11005	936 S OLIVE ST	90015	14	127-5A209 185	5139004015	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	plan check for power and energy. methane zone. 14010-100-00083. <<PDPP>>NEW 7 STORY 263 UNITS APARTMENT/ RETAIL(SHELL ONLY) & THREE LEVEL BASEMENT PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
245	16041-30000-17312	4102 S MUIRFIELD ROAD	90008	8	114B181   118	5031002002	[Q]RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01069	-118.34781	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
246	18041-20000-03023	4324 N PERLITA AVE	90039	13	159B205   403	5594011005	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.13186	-118.26812	PLAN CHECK FOR BATTERY BACK UP SYSTEM(TESLA POWERWALL 14KVA) WITH EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
247	10041-20000-10391	21031 W VENTURA BLVD #110	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	07/20/2010 12:00:00 AM	PIN	34.16717222	-118.59179488	S.110 OFFICE T.I.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
248	19041-10000-14864	10991 W ROSCOE BLVD	91352	6	192B173   410	2632026016	[Q]M2-1-CDO-CUGU, [Q]P-1-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.22	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.22167	-118.37013	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
249	13041-10000-32419	1301 N LUCILE AVE	90026	13	144A201   391	5427013031	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.08724	-118.28141	PV1, Install 2.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
250	14041-10000-06547	110 N GEORGE BURNS ROAD	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.07564	-118.38149	TI in an existing lab for Cedars Sanai Medical center. Full plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
251	14041-20002-01398	7734 N SALE AVE	91304	12	189B097  1032	2013017004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.21118	-118.6184	Modifications to approved set.  Change of inverter and reduction of total number of modules.  $0 submittal fee is due to Senate Bill SB-1222.  (((New rooftop PV system using two UNGROUNDED inverters for an existing single family dwelling.  Service Panel Upgrade is not a part of this permit and is to be pulled SEPARATELY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
252	18041-10000-07047	12800 W FOOTHILL BLVD	91342	7	216B161    27	2514007044	M1-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.29216	-118.41416	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 105400 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
253	19041-10000-04344	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Info Complete	02/08/2019 12:00:00 AM	ADDRESS	33.98645	-118.44148	T24 FOR EXISTING COMMERCIAL BUILDING, TOTAL SQUARE FOOTAGE = 1003 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
254	14041-10000-16603	9829 W VENICE BLVD	90034	5	120B165  1032	4313014035	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.02368	-118.39874	permit to be pulled at EPC counter only. plan check for energy only. CHANGES ON plans include multilevel controls for stockroom. Decrease in connected outdoor lighting load and less than 50 percent change per applicant. BLDG#14016-10-11848:  T.I. RENOVATION INCLUDING ALL INTERIOR FINISHES & EQUIPMENT, NEW STORE FRONT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
255	16041-20000-29470	830 N FAIRFAX AVE BLDG A	90046	5	141B177    97	5527002032	C2-1VL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.08635	-118.36121	PLANCHECK FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT. TWO BUILDINGS IN ON PLAN.  BUILDING A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
256	19041-20000-27857	13155 W HESBY ST	91423	4	171B157   889	2358005005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.16226	-118.42001	Plan check for Energy Storage System installed into existing PV system. Energy storage size: 13.5KW with 1 Tesla PowerWall 2.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
257	14041-10000-05822	1614 W WILSHIRE BLVD UNIT 101	90017	1	132A205   217	5142012005	C4-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.05542	-118.27078	CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE . TENANT IMPROVEMENT INCLUDING NEW NON-BEARING PARTITIONS, FINISHES, T-BAR CEILING. NO CHANGE IN PARKING. ENTREPRISE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
258	19041-20000-06901	959 N SEWARD ST 305	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	T24 PLAN CHECK TO STE 305 OF EXISTING COMMERCIAL BUILDING. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 7330SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
259	19041-20001-52436	6840 W SANTA MONICA BLVD	90038	4	144B181   494	5532028018	MR1-1, [Q]M1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	01/19/2022 12:00:00 AM	ADDRESS	34.09049	-118.34008	Expedite per applicant request.Plan check for PV roof mounted system, PV system size: 149.2KW DC, 120KW AC with 373 PV Modules and 6 inverters(20KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
260	18041-10000-22367	1127 W WILSHIRE BLVD 200	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	34.05287	-118.26415	PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT TO EXISTING MEDICAL OFFICE BUILDING (RADIOLOGY). SCOPE INCLUDES USING ALL EXSTING DISTRIBUTION EQUPIMENT WITH ALL NEW CONNECTED LOAD, TOTAL AFFECTED AREA = 1174 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
261	13041-20000-03085	3415 S SEPULVEDA BLVD ste 1250	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.02055	-118.42347	Install lighting and receptacle circuits, a transformer, and a panel.  Plan check for energy and emergency lighting. 3835sqft. Suite 1250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
262	16041-10000-43117	18090 W CHATSWORTH ST 1-6	91344	12	207B125   637	2731008023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.26437	-118.52668	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total area: 10850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
263	14041-10001-02377	3564 N MANDEVILLE CANYON ROAD	90049	11	153B133    47	4490021011	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	02/28/2014 12:00:00 AM	ADDRESS	34.11342	-118.50034	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 8 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel. (1)Transformerless inverter: SOLAREDGE SE6000A-US-ZB-U(32) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
264	18041-20000-04811	6038 N ETHEL AVE	91401	2	177B161   743	2331022045	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.18056	-118.41801	Plan check for the addition of (3) Tesla PowerWalls onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
265	19041-20000-32061	20815 W ACORN CIR UNIT #170	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.29456	-118.58717	Plan check for PV roof mounted system, System size: 3.15KW with 9 PV Modules and 9 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
266	17041-10000-39908	21301-21311 W VICTORY BLVD	91303	3	180B105    25	2148031016	WC	South Valley				1349.02	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Closed	05/24/2018 12:00:00 AM	ADDRESS	34.18858	-118.59682	Plan check for energy only for change of use from retail to furniture store total connected load is less than 400A . Total area: 35,848 sq ft.Note: THIS PLAN WAS DESIGN BUILT CONTRCATOR ON PLAN MUST PULL PERMITB# 17016-10000-32572	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
267	18041-20000-43007	2149 S CAMDEN AVE	90025	5	126B153   643	4322018011	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.04137	-118.43648	Plan check for PV roof mounted system, system size: 9.83kW AC, 11.16kW DC wtih 36 PV Modules and 36 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
268	18041-20001-42531	10921 W CHANDLER BLVD	91601	2	171B173    74	2416002006	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM			PC Approved	11/09/2018 12:00:00 AM	ADDRESS	34.16876	-118.3688	Revisions to approved plans.  Addition of exterior lighting to lighting plan.  (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,840 sq. ft.Note: Building permit has been issued under 18016-20000-42531)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
269	16041-10000-35930	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM	ADDRESS	34.04338	-118.26581	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (STAPLE CENTER). SCOPE INCLUDES ADDING NEW OUTDOOR LIGHTS FOR OUTDOOR KING MONUMENT. TOTAL AFFECTED AREA IS 150 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
270	19041-10000-06478	1011 W 69TH ST	90044	8	102B197   593	6014021007	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	33.97715	-118.29224	Plan check for a 3.8KW AC/ 2.52KW DC roofmounted system with (1) 3.8kw inverter, (8) modules and optimizer	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
271	19041-20000-46667	5115 N VESPER AVE	91403	4	171A151   102	2263035010	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	11/23/2019 12:00:00 AM	ADDRESS	34.16358	-118.45101	Plan check for PV roof mounted system, PV system size: 10.15KW DC, 9.28KW AC with 29 PV Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
272	11041-10000-24645	9301 N TAMPA AVE #183	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM			Corrections Issued	11/28/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I. to an existing retail space.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
273	16041-10001-15567	13056 W DELANO ST	91401	2	177B161   544	2331018013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM			Not Ready to Issue	06/08/2016 12:00:00 AM	ADDRESS	34.1821	-118.41741	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.845KWdc / 4.085KWac.(19)MODULES-CANADIAN SOLAR CS6P-255P(19)MICROINVERTERS-ENPHASE M215-60-2LL-S2X-IGNOTE: ORIGINAL PERMIT IS UNDER PCIS#16041-90000-15567(((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
274	17041-20000-33511	13116 N PORTOLA WAY	91342	7	225B165    19	2580018***	RD6-1XL	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.31079	-118.40494	Plan check for solar pv system, roof-mounted array on SFD.6.6kW ungrounded system. (27) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
275	17041-20001-43170	3915 W 7TH ST	90005	10	132B193   262	5092029045	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.05982	-118.31184	pv2install roof mounted pv system sized 16.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
276	15041-20000-25984	800 W OLYMPIC BLVD 4th Floor-5th Floor	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.04484	-118.26453	Title 24 plan check only.  Total area = 668 sq. ft.  T.I. to existing commercial office highrise.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
277	18041-20000-13682	6819 N BAIRD AVE	91335	3	183B125   956	2126023007	(T)(Q)R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.19449	-118.53746	New (23) device fire alarm system for 7 unit 3-story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
278	13041-20000-16958	3518 N COY DR	91423	5	159B153    48	2274025015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.13521	-118.44534	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW USING 29 MODULES. TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. SYSTEM CONTAINS POWER OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
279	12041-10000-18718												Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM			PC Approved	08/03/2012 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
280	19041-10000-18646	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.0834	-118.37568	PLAN CHECK FOR TITLE 24 ONLY FOR 2-STORY RETAIL BEAUTY SALON AND RESTAURANT TOTAL EFFECTED AREA 3250 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
281	14041-10000-08534	17614 W COLLINS ST	91316	5	174B129   604	2254012011	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.17374	-118.51672	PV1 5.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-5000-OUTD-US}]. [(22)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
282	18041-20000-01299	221 N FIGUEROA ST 1245&1275	90012	14	133-5A211 255	5161006909	C4-2D, [T][Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for Title 24 only. Project site is the partial 12th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,449 sq. ft.Note: Building application has been generated under 17016-10000-37029	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
283	19041-10000-17588	207 S DACOTAH ST	90063	14	126A225   330	5179004068	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Issued	05/10/2019 12:00:00 AM	ADDRESS	34.03781	-118.20153	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
284	15041-10000-13751	15301 W VENTURA BLVD # P-17	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.15411	-118.46654	TI FOR EXISTING SINGLE STORY COMMERCIAL BUILDING. PC FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQ. FT. 885SCOPE OF WORK WILL BE PERFORMED IN SUITE P-17	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
285	12041-10000-18491	10181 N RESEDA BLVD	91324	12	204B125   215	2729011004	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Expired	03/16/2016 12:00:00 AM	ADDRESS	34.25644	-118.53637	"REPLACING TWO SERVICES WITH ONE 600A UNDERGROUND SERVICE TO SUPPLY POWER TO EXISTING SAVON STORE. ALL LOADS ARE EXISTING.  ""COMPLY WITH DEPARTMENT ORDER effective date 06/17/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
286	15041-20000-42386	12156 W HART ST	91605	2	183B165   273	2321009042	R3-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			12/16/2015 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.19744	-118.39838	plancheck for power and energy for a New 26 unit apartment. New 1200A service. Total sqft. 30,000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
287	15041-20001-07238	3240 N WRIGHTWOOD DR	91604	2	159B173   384	2380037002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM			PC Approved	04/13/2015 12:00:00 AM	ADDRESS	34.13206	-118.37252	Supplemental application for expedite fees.Installation of new roof mounted solar PV array.  Total system size = 18 kWac.  2 inverters with 76 modules (7 strings).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
288	14041-20000-26718	12663 W SANDHILL LANE Unit #2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97743	-118.41479	PV2Install roof-mounted solar array on Unit #2 of commercial building. Each of the 3 Units will have their own solar array, interconnecting in their respective unit panels. All Unit panels fed off of the same 400A distribution board.System size: 3kW.(1) PVI 3.0-OUTD-S-US-A transformerless inverter(6) SunPower SPR-230NE-BLK-D pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
289	16041-10000-11513	580 S ALAMEDA ST	90013	14	126A215   246	5164009001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM	02/10/2017 12:00:00 AM		Issued	02/10/2017 12:00:00 AM	ADDRESS	34.03894	-118.23818	PC FOR ENERGY AND POWER. NEW 800 AMP SERVICE AND OUTDOOR LIGHTING NEW RECEPTACLES AND AC UNITS, LIGHTING WILL BE BUILD OUT BY TENANTS. TOTAL AREA 790 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
290	18041-20000-10039	16370 W MANDALAY DR	91436	5	162B137   246	2286003042	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.14137	-118.48935	pv1install roof mounted pv system sized 11.9kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
291	19041-10000-46973	4043 N WILLOW CREST AVE	91604	2	162B177   180	2423034026	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.1428	-118.36299	PLAN CHECK FOR A NEW BACKUP  DC BATTERY CONNECTED TO EXISTING PV SYSTEM. SCOPE INCLUDES NEW BACKUP PANEL SERVING CRITICAL LOADS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
292	14041-10000-25046	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	33.94386	-118.4047	NEW WATER TOWER LIGHTING SYSTEM AND FOR ASSOCIATED ELECTRICAL ROOM. ADDED LOAD IS LESS THAN 400A.PLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
293	11041-10000-19758	236 N LARCHMONT BLVD	90004	4	138B189   501	5515025002	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.07573	-118.32343	T-25 lighting plan check for new bakery in existing space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
294	16041-10000-00578	4201 W WILSHIRE BLVD #400	90010	4	135B189   972	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.06189	-118.31911	TI OF EXISTING OFFICE SPACE 4TH FLOOR. PC FOR ENERGY ONLY, TOTAL AREA 23,775 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
295	15041-10000-09965	2261 S FEDERAL AVE	90064	9	121-5A205 243	5126036008	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.03387	-118.44484	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHTING FIXTURES AND REPLACE WITH LEDS.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 4200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
296	12041-10000-30185	1616 S ABBOT KINNEY BLVD	90291	11	108B145  1611	4238017032	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM			PC Approved	12/14/2012 12:00:00 AM	ADDRESS	33.98968	-118.46365	Ti in a restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
297	15041-10000-18430	2049 S CENTURY PARK EAST SUITE 2410-S	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI TO AN EXISTING OFFICE SPACE IN HIGH RISE BLD. AND PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK IN 24TH FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
298	18041-10000-03387	3201 W 6TH ST	90020	10	135B197   956	5502024009	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Closed	01/24/2023 12:00:00 AM	ADDRESS	34.06376	-118.29222	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
299	14041-10000-30068	700 S LOS ANGELES ST	90014	14	127-5A211 193	5145002002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.04304	-118.25042	Tenant improvement for a retail grocery store in an existing cmu building.  Newly connected load exceeds 400A - plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
300	15041-20001-43546	1074 N AVENUE 51	90042	1	154-5A225 247	5478013017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	34.11799	-118.20549	Revisions to approved set.  Change of module model and manufacturer. PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (18)MODULES-SOLARWORLD SW 285 MONO(1)INVERTER-SUNNYBOY SMA SB5000TL-US-22Fees $0 due to SB 1222Plan check per EG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
301	15041-10000-26544	633 W 5TH ST LEVEL 04	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Expired	05/09/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY. NEW VISITOR INFORMATION KIOSK, LEVEL 04. TOTAL  AREA  (INDOOR+OUTDOOR) 5,435 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
302	16041-20000-11716	4540 N NATICK AVE	91403	4	168A149   141	2265001014	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.15434	-118.45402	Plan check for a PV2 roof-mounted PV system. System size is 25 kWac and consists of (2) inverters, (96) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
303	18041-20000-14921	18443 W BERMUDA ST	91326	12	207B125   148	2715007045	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Expired	04/27/2024 12:00:00 AM	ADDRESS	34.26649	-118.53517	PV1.  Install 6.745 kW DC rated PV system with 6 kW rated string inverter and (19) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
304	18041-20000-01513	420 S GRAND AVE	90071	14	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.05094	-118.25298	Installation of a new 900 kVA UPS system and associated cooling and distribution for nonemergency load backup in a commercial highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
305	18041-20000-03282	5610 N CAMELLIA AVE	91601	2	174B169   787	2338028019	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			01/29/2018 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	12/21/2020 12:00:00 AM	ADDRESS	34.17257	-118.38211	Plan check for power and energy. Project site is a 4-story, 62-unit apartment building with 1 level of basement parking garage. Work includes a 1,600-amp service and a total lighting area of 22,776 sq. ft.Note: Building application has been generated under 16010-20000-06202	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
306	11041-10000-26788	2670 N GRIFFIN AVE	90031	1	139-5A223  15	5206010039	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.07841	-118.21167	Tenant improvement on 3 story commercial bldg, lighting power, title 24, fire alarm under separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
307	18041-20002-19734	16152 W COVELLO ST	91406	6	186B137    96	2205022015	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM			Corrections Issued	11/05/2018 12:00:00 AM	ADDRESS	34.20741	-118.48542	11-05-2018 Changes to an approved set of plan, Changes include relocate inverters from electrical room to roof. Changes apply to clouded area: only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
308	19041-10000-53500	10009 N SHOUP AVE	91311	12	204B101   638	2745009030	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.25193	-118.61508	NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 31 MODULES (LG320N1K-V5), 31 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE7600H-US)SYSTEM SIZE: 9.92 KW DC; 7.6 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
309	14041-10000-35246	8371 N CANOGA AVE	91304	3	192B105   479	2779022260	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.22205	-118.59771	Title 24 plan check only.  Total area = 19,252 sq. ft.Remove HID light fixtures and replace with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
310	10041-10000-12536	18700 W VENTURA BLVD #120	91356										Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM			Reviewed by Supervisor	07/27/2010 12:00:00 AM	ADDRESS	34.17045	-118.54081	TENANT IMPROVEMENT FOR STARBUCKS COFFEE 1842 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
311	19041-20000-08750	10461 N RAINTREE LANE	91326	12	207B121   716	2728031061	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.26129	-118.54327	Plan check for PV roof mounted system, system size: 13.53KW DC, 12.65KW AC CEC  with 41 PV Modules and 2 inverters(7.6KW and 6.0KW), sub-panel connected to 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
312	16041-10001-14481	2626 E 25TH ST	90058	14	117A219   417	5168022006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM			PC Info Complete	05/09/2016 12:00:00 AM	ADDRESS	34.0152	-118.22477	5/9/16: Per applicant, the master plan is LOST, supplemental number and new plan check has been created under this application.<<REMODEL PORTION OF EXISTING MANUFACTURING BUILDING, ADDING NEW MOTOR LOAD WITH TOTAL NEW CONNECTED IS LESS THAN 400A.  PC FOR T-24 ONLY. TOTAL AREA: 8,112 SQ.FTB# 16016-10000-04343>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
313	13041-20000-11064	5940 N CANTALOUPE AVE	91401	2	177B153   923	2246006023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	06/17/2013 12:00:00 AM	ADDRESS	34.17876	-118.43439	PV1 SINGLE STORY SINGLE FAMILY DWELLING. 2.59KW. [MICROINVERTER: ENPHASE M215-60-2LL-S22/S23] [SOLAR MODULE: OPTIMUS SERIES OPT 60 CELL].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
314	14041-20000-16340	12335 W SATICOY ST	91605	2	186B165   218	2307016020	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.20861	-118.40194	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.75KW INTERCONNECTED WITH MAIN PANEL.(19) SUNMODULE SW250 WITH POWER OPTIMIZERS(1) SOLAREDGE TRANSFORMERLESS INVERTER SE5000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
315	19041-20000-30064	1918 W SUNSET BLVD	90026	13	139-5A207  82	5404001040	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1957.20	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM			PC Info Complete	08/02/2019 12:00:00 AM	ADDRESS	34.07781	-118.26133	Plan check for  Title 24 only in existing space T.I. Total area: 1346 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
316	19041-10000-36253	11800 S CENTRAL AVE	90059	15	084B209   509	6148011025	C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	33.92617	-118.25411	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
317	13041-10001-24454	200 E ANAHEIM ST 1ST FLOOR	90744	15	030B209   236	7423012031	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	33.77994	-118.2608	"Changes to an approved set of plans. Changes include revised loads to panel ""P1"" and the addition of panel ""P1B"" and associated loads. 1/29/2015(((TI, REMODELING OF EXISTING MEDICAL OFFICE/EXAM IN A TWO-STORY BUILDING. WORK IS PERFORMED ON THE FIRST FLOOR. APPROXIMATE OFFICE SIZE IS 54,000 SF. REMODELING WILL BE FOR ADDING NEW LOADS ON EXISTING PANELS AND LIGHTING)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
318	18041-20000-26397	3995 S DEGNAN BLVD	90008	10	114B185   103	5033006033	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.01191	-118.33165	Plan check for PV roof mounted system, system size: 3.8kW with 13 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
319	18041-10000-02327	132 N ROSEMONT AVE	90026	13	136-5A205 182	5157018024	R3-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			01/22/2018 12:00:00 AM			PC Info Complete	07/26/2019 12:00:00 AM	ADDRESS	34.06864	-118.27209	PC FOR PROPOSED NEW 4-STORY APARTMENT BUILDING (14 UNITS) FOR POWER AND ENERGY. WITH GARAGE ON BASMENT LEVEL.  NEW SERVICE RATED AT 800A 120/240V 3PH. TOTAL AFFECTED AREA 12378 SQ. FT (INDOOR  & OUTDOOR). WITH THREE  TYPICAL UNITS. B#18010-10000-00228	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
320	14041-10000-25653	309 S SERRANO AVE	90020	10	135B193   246	5503004013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.06857	-118.30689	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. ASSEMBLY OCCUPANCY. PLACE OF WORKSHIP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
321	13041-20000-29854	2557 N ALMADEN CT	90077	5	153B153    26	4382029***	RE15-1-H-RPD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	10/24/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.11874	-118.44413	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 6.04KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
322	10041-20000-15729	6920-6924 W VALMONT ST	91042	2	202-5A201   4	2568003015		North Valley				1012.20	Electrical	Electrical	Public Safety Only			08/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.25171	-118.28229	Plan check for installation of new fire sprinkler notification system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
323	14041-20000-14279	13629 W HARTLAND ST	91405	2	183B157   834	2328012045	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.195	-118.42984	PV1.  Install 11.25 kW roof-mounted utility-interactive PV system.  Transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
324	18041-20000-46757	22454 W FRIAR ST pv1	91367	3	177B101    11	2039025003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.1854	-118.61663	pv1install roof mounted pv system sized 15.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
325	10041-20000-05804	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	05/12/2010 12:00:00 AM		Permit Expired	09/24/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Delta 3 revisions to 08041-20000-22411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
326	14041-10000-08162	4415 S CENTRAL AVE	90011	9	112-5A209  93	5108028023	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	34.00344	-118.25677	permit to be pulled at EPC counter only. Plan check for energy only. Lighting for stairwell of 2 story retail building BLDG#: 13016 20001 20989: Supplemental permit to add (N)stair	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
327	18041-10000-26146	21300 W ROSCOE BLVD	91304	3	192B105   610	2109001003	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.21955	-118.59643	PLANCHECK FOR POWER AND ENERGY. NEW AUTOMOBILE SALES FACILITY. 800 AMPS SERVICE. 114,570 SQFT BUILDING PERMIT # 18010-10000-01472	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
328	18041-20000-38133	18325 W SHERMAN WAY	91335	3	183B125   109	2119023007	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.20129	-118.53263	Change of use from retail to medical office/pharmacy and office use.  New 600A 240/120V 1ph-3w service. Building permit filed under 18014-20000-00271.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
329	14041-10000-12857	16258 W SHADOW MOUNTAIN DR	90272	11	132B121   298	4420039018	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.05743	-118.53911	PV1 MICROINVERTER PLAN. SERVICE SIZE 600AMPS. TOTAL SYSTEM SIZE 19.7KW. 73 MODULES. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
330	16041-20000-10799	15760 W VENTURA BLVD SUITE 700	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.1552	-118.47684	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 700.  1637 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
331	13041-10000-12811	1490 W 7TH ST	90732	15	015B193   350	7452034035	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	33.73806	-118.30936	pc for power and energy. NEW ONE STORY COMMERCIAL BUILDING. SUITE A DENTISTS OFFICE (medical), SUITE B--OFFICE SHELL ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
332	19041-30000-29384	11311 W MISSISSIPPI AVE	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.03944	-118.443	PLAN CHECK FOR TITLE 24 ONLY REMODEL TO EXISTING ICE CREAM SHOP. TOTAL AFFECTED AREA 703 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
333	15041-10000-27135	2313 S SPAULDING AVE	90016	10	123B173    49	5064028015	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	09/04/2015 12:00:00 AM	ADDRESS	34.03711	-118.3678	Changes made to original online permit application 15041-90000-23856.   Module and microinverter models changed from original proposed.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
334	11041-10000-00206	13515 S FIGUEROA ST	90248	15	078B201   102	6132005009	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20, 2911.30	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	01/05/2011 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	PIN	33.90872221	-118.28341949	INSTALL A NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
335	16041-10000-09092	900 W WILSHIRE BLVD 72nd floor	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	First time tenant. Full PC to a multi used high rise building hotel/restaurant (73 floors total). Scope of work is being done in the 72nd floor. Total sq ft =7000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
336	19041-10001-03968	2806 S ELLENDALE PL	90007	9	123B197  1598	5055012003	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.02933	-118.28859	chasnges to approved set - changes include module modification (solarcity standard #sc330)original permit Plan check for PV1 7.6KW AC roofmounted system with (21) module and (1) inverter interconnecting through the main panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
337	16041-30000-35498	14570 W EL CASCO ST	91342	7	225B149   114	2504003003	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.31604	-118.44984	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 9.5 kWac.  Microinverter system with 3 branch circuits and a new 100 amp AC load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
338	13041-10000-26490	754 E PICO BLVD	90021	14	123A211   141	5132019045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Info Complete	11/07/2013 12:00:00 AM	ADDRESS	34.03189	-118.25227	PLAN CHECK POWER AND ENERGY FOR WHOLESALE STORE/WAREHOUSE BUILDING. EXISTING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
339	14041-20000-11775	17013 W TIMBER RIDGE DR	91344	12	225B133    41	2601012032	RS-1, RS-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.31365	-118.50249	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. 30 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
340	19041-20000-25289	6150 N LAUREL CANYON BLVD STE 140	91606	2	177B165  1100	2334011029	(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	01/29/2021 12:00:00 AM		Permit Finaled	05/12/2021 12:00:00 AM	ADDRESS	34.18223	-118.39491	POWER AND ENERGY PLAN CHECK FOR FIRST TIME TENANT T.I. FOR A NEW RESTAURANT WITHIN AN EXISTING RESTAURANT SPACE IN A MULTI TENANT COMMERCIAL SHOPPING CENTER BUILDINGBUILDING PERMIT UNDER 19016-10000-19907	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
341	19041-10000-53447	13864 W FOOTHILL BLVD	91342	7	225B153   386	2509003010	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.31117	-118.43555	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
342	13041-20000-25422	1050 W CHILDS WAY	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	10/02/2013 12:00:00 AM	ADDRESS	34.02262	-118.29103	Change to lighting in an existing Laboratory.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
343	14041-20000-30983	11835 W BLYTHE ST	91605	6	189B169   284	2310022019	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.21492	-118.39111	Roof mounted PV system with transformerless inverter. Total system size is 3.9KW.Note: The solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
344	19041-20000-21361	20700 W SESNON BLVD #178	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Issued	06/05/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	Plan check for a PV1 roof-mounted PV system. System size is 5.03 kWdc/4.8 kWac and consists of (15) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
345	16041-10000-00657	1149 S BROADWAY 6TH FLR	90015	14	126A209   600	5139019900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Expired	02/15/2018 12:00:00 AM	ADDRESS	34.03859	-118.26015	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 6TH FLOOR(OPEN OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 183 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
346	17041-20001-18651	11800 N SUSAN DR	91344	12	216B137   517	2609005003	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			PC Approved	07/07/2017 12:00:00 AM	PIN	34.28503706	-118.4982564	expeditepv1install roof mounted pv system sized 13.2kw intercionnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
347	15041-20000-40286	8854 N QUAKERTOWN AVE	91324	12	195B113   101	2782033001	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.23154	-118.56977	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (23) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
348	18041-10000-30005	5249 W CENTURY BLVD	90045	11	090B173    93	4128017044	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	06/18/2021 12:00:00 AM	ADDRESS	33.94558	-118.37196	PC FOR POWER FOR EQUIPMENT UPGRADE WITH NEW CIRCUITS IN LA-QUINTA HOTEL. SCOPE INCLUDES  SWITCHGEARS CHANGE OUT AND ADDITION OF CIRCUITS TO APROX. 250 GUEST ROOMS. PARTIAL  permits have been pulled under 17041-10000-17846 and 17041-20000-08504. THIS IS A REDESIGN OF WORK PROPOSED UNDER 17041-100000-44078 FOR Added circuits for refrigerator and microwave for 254 units at LaQuinta Hotel. (B# 16016-10000-28180)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
349	14041-20000-00190	21021 W VENTURA BLVD 103	91367	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	PIN	34.16705846	-118.59120236	Office Tenant Improvement	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
350	19041-20000-29753	6363 W WILSHIRE BLVD ste 516	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.06385	-118.3674	ti to an existing commercial building.  adding new lighting new controls to existing panel. plan check for indoor energy only. high rise building. medical office, consultation only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
351	19041-20000-23607	5720 S 2ND AVE	90043	8	108B189  1029	5005005901	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	02/19/2021 12:00:00 AM	ADDRESS	33.99083	-118.31908	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW 1-STORY POOL & BATH HOUSE. SCOPE OF WORK INCLUDES 1 FACP AND 30 FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
352	13041-10000-28992	920 W HARRY BRIDGES BLVD	90744	15	027B205   665	7440007901	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			Reviewed by Supervisor	10/30/2013 12:00:00 AM	ADDRESS	33.76949	-118.27079	PLAN CHECK FOR POWER AND ENERGY. PORT OF LOS ANGELES. NEW REPAIRSHOP FOR AUTOMATED CRANES. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
353	18041-20000-11035	706 N ALVARADO ST 1-34	90026	13	138A207    49	5404008010	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Apartment			03/27/2018 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	34.07393	-118.26551	New 34-unit lowrise apartment building 5 stories over one story parking.  1600A 240/120V 3ph-4w service.Building permit under 17010-20000-04059.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
354	14041-10000-07978	3150 W WILSHIRE BLVD #118	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	"TENANT IMPROVEMENT FOR ""NEW"" ""JIMMY JOHN'S"" RESTAURANT INTO NEW HIGH RISE WITH RESTAURANT USES;"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
355	15041-10000-12024	200 WORLD WAY TERM 2-# 236	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	AT LAX, INSTALLATION OF ILLUMINATED SIGNS FOR TENANATPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
356	14041-10001-05201	4129 N FARMDALE AVE	91604	2	162B169   140	2368022004	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.14344	-118.38128	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 7.5 kW DC roof-mounted solar array on a 2-story home, interconnect with EXISTING service panel. (1)Transformerless inverter: Solaredge SE 6000A-US. (30) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
357	18041-10000-10897	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Issued	08/23/2018 12:00:00 AM	ADDRESS	34.17126	-118.58861	PC for power for install of 3.141MW fuel cell system for Kaiser OSHPD building. Installing new switchboards, eight 300kW, one 210kW and two 262.5kW fuel cell units. Fuel cells designed to be used as the primary source of energy for building adnd supplies building through 1500kW and 2500kW transformers. All new equipment to be installed outside the building.B# 18020-10000-00754.INSTALL OF A FUEL CELL GENERATOR WITH CONCRETE PAD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
358	13041-10000-26267	13813 W LOUVRE ST	91331	7	207B153   477	2618009020	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.26415	-118.43408	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200A MAIN IN A 1-STORY HOUSE. WORK IS DONE ON A CENTRAL INVERTER SYSTEM, STANDARD PLAN. COMBINER BOX WILL BE USED. SYSTEM SIZE IS 6 KWDC WITH (24) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG 5100 NEG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
359	13041-20000-14673	13266 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW. USING MICROINVERTER STANDARD PLAN. ENPHASE M215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
360	18041-20002-05571	11838 W VENTURA BLVD	91604	2	162B169   275	2369027016	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.14236	-118.39049	08-07-2018 Changes to an approved set of plan. changes include revised receptacle location. All changes has been clouded as delta 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
361	13041-20000-35977	5643 N WILHELMINA AVE PV1	91367	3	174B089   427	2046014005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.17235	-118.64966	New rooftop PV system for an existing single family dwelling.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
362	11041-20000-15421	8252 N VAN NUYS BLVD	91402	6	192B149   400	2212004001	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	05/16/2012 12:00:00 AM	ADDRESS	34.22127	-118.44856	ADD 40 HP ELEVATOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
363	17041-10000-09006	10250 W SANTA MONICA BLVD #1585	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PC FOR FIRST TIME TI ""LIFEHOUSE""  IN WESTFIELD CENTURY CITY. SUITE 1585"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
364	14041-10000-12910	1326 E MONTECITO DR	90031	1	144A227   315	5304026007	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.0888	-118.19711	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
365	16041-20000-22434	15637 W MARILLA ST	91343	12	201B141   318	2671007007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Expired	07/31/2018 12:00:00 AM	ADDRESS	34.24736	-118.47324	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
366	16041-20000-13454	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Closed	12/08/2017 12:00:00 AM	ADDRESS	34.01318	-118.34004	Plan check for power only. TEMP POWER - 600A service for construction trailers. Phase 1 of temp power project for medical building construction.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
367	10041-10000-24524	3571 W WILSHIRE BLVD	90010	10	132B193    19	5503025013	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2124.10	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	34.06192	-118.3025	Ti in an existing restaurant. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
368	19041-20000-13225	515 S FIGUEROA ST Ste 1200	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
369	19041-10000-29766	801 S ALVARADO ST	90057	1	132A203   230	5141021022	C2-1	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/15/2020 12:00:00 AM	ADDRESS	34.05479	-118.27815	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
370	12041-10000-01816	2131 N HILLHURST AVE	90027	4	150B197    76	5590003040	C4-1D	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.11109	-118.28759	NEW 2-STORY + BASEMENT OFFICE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
371	13041-10000-01756	7612 S BOEING AVE	90045	11	099B169  1505	4106008012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	33.97117	-118.39166	PHOTOVOLTAQIC SYSTEM FOR SINGLE STORY SINGLE FAMILY DWELLING. USING MICROINVERTER ENPHASE M215-60-2LL-S22. SOLAR PANEL - REC 245 PE. TOTAL 2.216 KW SYSTEM. 10 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
372	12041-10000-06560	8630 N TAMARACK AVE	91352	6	195B169   467	2631018078	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	07/11/2012 12:00:00 AM	ADDRESS	34.22786	-118.38538	Change of use from warehouse to ambulance dispatch office.  Occupancy load of 88, connected load over 400A.  Plan check for Power and Energy.  No suite number per applicant.  NOTE: THIS PERMIT DOES NOT INCLUDE THE INVESTIGATION FEES DUE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
373	15041-20000-12502	23472 W FRIAR ST	91367	3	177B093    18	2035009001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.18548	-118.63932	Installation of new roof mounted solar PV array.  Total system size = 5.375 kWac.  Microinverter system with 2 branch circuits.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
374	18041-20000-07712	2329 S SUPERIOR AVE	90291	11	108B149   333	4242001028	[Q]R4-1XL	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Apartment			03/02/2018 12:00:00 AM			PC Info Complete	02/10/2023 12:00:00 AM	PIN	33.9945801	-118.45260504	New 5-story 56-unit apartment building.  1200A 208Y/120V 3ph-4w service.Building permit under 17010-20000-04274	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
375	18041-10000-12143	620 N PALMERA AVE	90272	11	129B121   966	4414012017	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.04599	-118.53891	INSTALL 4 NEW BATTERY SYSTEM TO AN EXISTING PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
376	14041-20000-20030	11125 N CABRIOLE AVE	91326	12	210B121   290	2717006005	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Expired	08/26/2016 12:00:00 AM	ADDRESS	34.27225	-118.54126	PV1Microinverter standard plan. Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5.805kW(27) EnPhase M215-IG microinverters(27) Hyundai HiS-S250MG pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
377	18041-20000-43801	732 S WARNER AVE	90024	5	135B153   149	4360027008	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM			Reviewed by Supervisor	12/21/2018 12:00:00 AM	ADDRESS	34.06783	-118.43304	Plan check for power only. Project site is a 2-story single family dwelling. Work includes a new 600-amp service.Note: Building permit has been issued under 18010-30000-01286. Electrical permit fees have been paid under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
378	17041-10000-24961	3576 N SEPULVEDA BLVD	91403	5	162B141   488	2280021023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.13646	-118.48517	PV1. PC FOR PV SYSTEM USING AC MODULES. TOTAL OF 32 MODULES. TOTAL SYSTEM SIZE Is 10.24 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
379	14041-10000-33141	9841 N AIRPORT BLVD Suite 812	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94647	-118.38626	Plan check for Title 24 only. Total lighting area = 4960 sq. ft. Project site is commercial (single suite on the 8th floor of a high-rise office building).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
380	18041-10000-37004	255 E 28TH ST	90011	9	120A207   278	5128002043	[Q]R3-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.02218	-118.26686	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
381	18041-20000-18443	14841 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.29487	-118.4547	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.87kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
382	11041-10001-05711	5555 N VAN NUYS BLVD	91411	2	174B149   958	2249001018	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00, 1288.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.1717	-118.44906	Modificaiton to approved set of plans for lighting and circuit changes.           <<<<<<4,306 SF CHASE BANK BUILDING.  Full plan check requested by applicant.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
383	19041-10000-29392	189 S THE GROVE DR J1B	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	PLAN CHECK FOR TITLE 24 ONLY(TAILOR METHOD) FOR TENANT IMPROVEMENT FOR (E) RETAIL SPACE. TOTAL AFFECTED AREA = 2382 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
384	17041-20001-42262	8755 W YATES ST	91040	7	204B189   414	2546002019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.25675	-118.32433	expeditepv1install roof mounted pv system sized 5kw interconnected with msp, with battery back up.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
385	15041-20001-37308	10046 N SAMOA AVE	91042	7	202-5A199  24	2568006036	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			02/20/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.25157	-118.28721	Plan check for changes to approved set of plans - changes are include under single line diagram which include relocation of disconnect of PV meter, feeder lengths to unit panels, and removal of makeup air fan. Changes were noted under Delta 1,2,3 & 4Plan check for power and energy for a new 3-story, 48-unit apartment building (1 level of below-ground parking with 3 levels of residential). Service size is 2,000 amps. Total indoor lighting area = 33,183 sq. ft. and outdoor lighting area = 9,000 sq. ft.Note: Building application has been filed under application number 11010-10000-01574 and was submitted on 07/2011	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
386	13041-10001-10169	6433 N FIGUEROA ST	90042	14	154-5A231  71	5493005010	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01, 1832.20	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.11885	-118.18382	[][]CHANGES MADE TO AN APPROVED SET OF PLANS; ADDING NEW TRACK LIGHTS ON RETAIL SPACE AND REPLACING FLOURESCENT LIGHTS FOR NEW LEDS IN THE BATHROOM[][][][] TI OF EXISTING RETAIL SPACE. NO CHANGE OF USE. NBEW LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 4160 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
387	19041-20000-28970	18442 W MONTAGE LN	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	06/09/2021 12:00:00 AM				new sfd 600 amp service.  plan check for power only.  permit fees paid under building combo permit 18010-20000-05068	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
388	18041-20000-28192	14524 W FILMORE ST	91331	6	201B149    36	2647026004	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.25151	-118.44912	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWdc/4.352 kWac-CEC and consists of (1) 5 kWac rated inverter and (16) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
389	16041-20000-02249	17918 W DUNCAN ST	91335	5	180B129  1081	2123017011	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Expired	02/20/2018 12:00:00 AM	PIN	34.18563126	-118.52368541	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel. Standard plan in use.(22) Kyocera KU265 Modules(1) ABB PVI-5000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
390	19041-20001-02910	12322 W HESBY ST	91607	2	171B165   966	2356024003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM			PC Approved	02/07/2019 12:00:00 AM	ADDRESS	34.16215	-118.40179	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
391	15041-20000-05934	6855 N TUJUNGA AVE	91605	2	183B173   210	2320003002	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.19546	-118.37923	Power plan check for 800 A service upgrade in existing commercial building. Plan approve per Elie.M	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
392	18041-10000-03975	11285 W NATIONAL BLVD	90064	11	120B157   345	4258017003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Issued	02/07/2018 12:00:00 AM	ADDRESS	34.02652	-118.43134	PC for T24 only for new lighting in a new office room. Installing new lights(indoor + Outdoor) and new receptacles. B# 18016-30000-00998.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
393	19041-20000-08780	3410 S GRANVILLE AVE	90066	11	117B153   825	4249010003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.01529	-118.43383	NEW 10.5KW AC ROOFTOP PV SYSTEM ON (E) SFD. SCOPE OF WORK INCLUDES (30) 360W SUNPOWER MODULES WITH 30 ENPHASE IQ7 MICROINVERTERS,.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
394	11041-20000-16786	3210 S HELMS AVE	90034	10	123B169  1779		[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.03079	-118.38465	Ti for a retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
395	15041-20000-28827	606 S AVENUE 61	90042	14	150A231   361	5312026048	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.10588	-118.18224	Plan check for PV roof mounted system. System size: 3.6kW with 12 modules and 1 inverter(3kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
396	19041-10000-09852	6560 N WINNETKA AVE 1-25	91367	3	180B113   835	2134024015	A1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	Apartment			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.19004	-118.57074	PC FOR FIRE ALARM CONTROL PANEL REPLACEMENT (LIKE TO LIKE) TO AN EXISTING FA SYSTEM. SCOPE ALSO INCLUDES A CELLULAR DIALER PANEL AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
397	16041-10003-23313	10250 W SANTA MONICA BLVD 202	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM			PC Approved	11/03/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	REVISIONS TO PERMITTED SET OF PLANS. SEE ATTACHED TO THE REVISED PLANS THE LIST OF CHANGES(((((((PC FOR POWER AND ENERGY. THE INTERIOR BUILDING OUT OF AN EXISTING SHELLED OUT TENANT SPACE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
398	13041-10000-14387	2030 S WESTGATE AVE	90025	11	123B149   349	4262033021	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.03465	-118.45236	pc for power only. TAKE OUT TWO (2) 400A FEEDER FROM AN (E) SWBD AND FEED IT FROM A NEW SWBD 1200A. feeders are not underground. not a hazardous location per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
399	16041-10000-41979	14750 W SHERMAN WAY	91405	6	183B149    90	2219006001	R1-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.20097	-118.45456	PC FOR T24 ENERGY ONLY. REPLACEMENT OF LUMINAIRES TO MORE ENERGY EFFICIENT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
400	15041-10001-25985	1719 S KELTON AVE	90024	5	129B153   363	4324029038	[Q]R2-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.05099	-118.44079	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 3.71 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOME.(14) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
401	15041-20000-44033	1252 W YOSEMITE DR	90041	14	160-5A229 333	5480020024	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Expired	03/05/2018 12:00:00 AM	ADDRESS	34.13284	-118.19273	Plan check for a PV1 roof-mounted PV system. System size is 3.9 kWac and consists of (18) micro-inverters, (18) modules, and (1) load center. Project site is a duplex; each house is getting its own PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
402	17041-10002-21386	7866 W FAREHOLM DR	90046	4	147B177    94	5551004011	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2017 12:00:00 AM			PC Approved	09/06/2017 12:00:00 AM	ADDRESS	34.10298	-118.36114	FOR CHANGES TO APPROVED SET TO REFLECT INSTALLATION OF LADWP METER  ON THE PALN. THIS IS PLAN CHECK ONLY!!!PERMIT UNDER MASTER.PC FOR PV SYSTEM. TOTAL SIZE 11.5KW AC. USINCE AC TYPE SOLAR PANELS. TOTAL OF 32 AC MODULES. ALL ROOF MOUNTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
403	18041-10000-09843	10900 W WILSHIRE BLVD Suite 850	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	PC FOR OFFICE TI FOR T-24  ENERGY ONLY.INSTALLING NEW LIGHTS ON EXISTING CIRCUITS (MODIFICATIONS IN PLAC) AND RECEPTACLES. TOTAL 4754 SQ.FT  .B#18016-30000-07976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
404	11041-10000-02149	1500 W FRANCISCO ST	90501	15	057B193    27	7351021039	M3-1, PF-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	ADDRESS	33.84954	-118.30384	Replace an existing 800 ampere service with a new 800 ampere service to accomodate the installation of a vehicle charging system.  Including a  300 kva transformer, panels, 15 vehicle charge stations, and reconnect existing feeders.  The dedicated PV circuit breaker for the existing PV System will be changed from 200 amperes to 150 amperes,  installed,  and labels provided to comply with the point of connection requirements of 690.64(B)(7) of the 2010 CEC.  Inspector to verify new connection requirements.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
405	11041-10000-26500	6820 S CENTINELA AVE	90230	11	105B165   433	4220014026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM	ADDRESS	33.98415	-118.40155	T.I. to an existing commercial space.  Change to lighting,  permit was already pulled on a seperate application.  PLAN CHECK ONLY for Energy, Emergency lighting was not verified per applicant's request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
406	13041-10000-28244	245 N VERMONT AVE	90004	13	138B197   409	5518033001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.07588	-118.29188	TITLE 24, PLAN CHCK ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH FLOURESCENT FIXTURES.PERMIT TO BE ISSUED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
407	15041-20000-19284	7605 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.20872	-118.46495	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
408	18041-10001-27423	8345 N LAUREL CANYON BLVD	91352	6	192B165   367	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1210.10	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.22292	-118.39669	SUPPLEMENTAL FOR CHANGES FOR APPROVED SET OF PLANS. CHANGES TO LIGHT FIXTURE TYPES,  ADDITION OF X RAY MACHINE AND AIR COMPRESSOR, UPDATE TO PLAN NOTES, PANELSCHEDULE, AND T24 SHEETS.DELTA 5, 6, AND 7 CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
409	14041-10000-13227	3516 N FARNSWORTH AVE	90032	14	144A237   385	5219018015	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.08662	-118.16728	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A2-STORY JOUSE, INTERCONNECT WITH MAIN SRVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
410	18041-10000-13528	7538 N VALJEAN AVE	91406	6	186B137    66	2205021011	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.20789	-118.48574	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
411	18041-20001-44200	2227 N OUTPOST DR	90068	4	153B181   319	5572008012	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.11277	-118.34479	Expedite feePV1.  Install 19.215 kW roof mounted grid tied PV system.  (61) modules with 11.4 and 3.8 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
412	15041-20000-40237	13479 N GLENOAKS BLVD	91342	7	225B145    57	2501020012	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.31709	-118.46235	New single-story commercial building (visitor/education center) w/ 800A 120/240V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
413	17041-10000-05265	4100 W PICO BLVD	90019	10	129B189   974	5072006028	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.04747	-118.32491	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 6,700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
414	18041-30001-18002	1800 N VINE ST 3RD FLR	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM			PC Approved	07/24/2018 12:00:00 AM	ADDRESS	34.10393	-118.3265	This is plan check only, permit is covered under master# 18041-30000-18002: Revisison to approved set of plan, noted as Delta-1. Replace corridors light and an office lights; floor plan, T24, and photometric are revised accordingly. <<PLAN CHECK FOR T24 ONLY, TI ON 3RD FLOOR EXECUTIVE OFFICE SUITES, CORRIDORS, OFFICES AND BREAK AREA. TOTAL AREA: 18,665 SQ.FT, NEW CONNECTED LOAD < 200A>>(B# 18016-10000-14440)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
415	13041-10000-25751	11726 W SAN VICENTE BLVD #420	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.05328	-118.46625	PC FOR ENERGY ONLY. TI TO (E) OFFICE. POSSIBLE HIRISE. HAS GEN. #420 (NTR partners in brentwood executive plaza)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
416	10041-10000-12438	1000 E 7TH ST	90021	14	126A213   531	5146001001	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	02/07/2011 12:00:00 AM		Permit Finaled	10/07/2011 12:00:00 AM	ADDRESS	34.03846	-118.24391	MAJOR REMODELING OF EXISTING HOTEL.   PLAN CHECK IS FOR POWER & ENERGY.  A variance to separate the electrical and fire alarm plan check and permits was submitted on August 27, 2010.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
417	14041-20000-00986	6382 W RIGGS PL	90045	11	102B165   123	4110012010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	33.97801	-118.39895	pv1 single family dwelling. total system size 4.2 kw ac using transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
418	18041-20000-05511	345 E 51ST ST NE park-lights	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	33.99665	-118.26853	plan check for outdoor energy lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
419	18041-10000-26203	10306 W VENICE BLVD	90232	5	117B165    21	4208005038	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	PIN	34.02078391	-118.40268239	PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT WITHIN CORE AND SHELL. CONNECTING TO EXISTING DISTRIBUTION EQUIPMENT WITH APPROX. 200A OF NEW CONNECTED LOAD. TOTAL AFFECTED AREA = 1105 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
420	14041-10000-00461	3933 W SENECA AVE	90039	13	157-5A207 131	5435003007	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Expired	02/02/2016 12:00:00 AM	ADDRESS	34.1254	-118.26182	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 4.3 KW.(20) ENPHASE M215 MICROINVERTER(20) SOLARWORLD SW250 POLY MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
421	13041-20000-30375	9525 N SHOSHONE AVE	91325	12	201B129   409	2755006003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.24416	-118.5179	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.6 KW AC USING 37 MODULES. 2 TRANSFORMERLESS INVERTERS, 2 STRINGS/INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
422	13041-20000-25774	7255 N WINNETKA AVE	91306	3	186B113   754	2114018014	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Apartment			09/18/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.20295	-118.57119	New 20.28kw rooftop mounted PV system on an existing 2-story apartment building.   Service upgrade from 100amps to 225 amps is on a separate application.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
423	13041-20000-35198	3415 N GREEN VISTA DR	91436	5	159B133   182	2287010070	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.13243	-118.49905	"PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.  "" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
424	18041-10000-16449	19320 W PLUMMER ST	91324	12	198B117    73	2761037001	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.24254	-118.55412	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
425	16041-20000-14582	350 S FIGUEROA ST 501, 700	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.05438	-118.2549	TI to (E) commercial office spaces in a commercial highrise building.  13,707 sq. ft. Plan check for energy; newly connected load is below 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
426	17041-10001-40594	10250 W SANTA MONICA BLVD #1893	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Revisions to permitted set ofplans: CHANGES TO THE LIGHTING SYSTEM -SEE ATTACHED LIST OF CHANGES(((((Full Plan check for first time tenant space ""Malin + Goetz""  suite 1893"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
427	12041-10000-07921	555 W 5TH ST 7TH FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/06/2012 12:00:00 AM			PC Approved	04/06/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	condtruction of new conference room and private office PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
428	15041-20000-36008	5543 E VIA MARISOL	90042	14	150A231   248	5301010015	RD1.5-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Expired	11/23/2017 12:00:00 AM	ADDRESS	34.10408	-118.18676	PV1, roof mounted solar panel, 2.565 kW system(9) modules: 285Mono(9) microinverters: Enphase M250standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
429	16041-20000-12543	20335 W ENADIA WAY	91306	3	183B113    94	2136001010	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.2002	-118.57662	Install a roof-mounted solar array on a SFD. Interconnect with a 125A MSP.System size: 4.16kW. Ungrounded system. (13) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
430	10041-10000-07536	1620 N SPRING ST	90012	1	136-5A217  49	5409002016	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	PIN	34.06858375	-118.22830481	INSTALL A NEW CNG COMPRESSOR AND DISPENSER/EQUIPMENT FOR CNG VEHICLES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
431	15041-10001-21032	2239 S PONTIUS AVE	90064	5	126B153  1005	4322024039	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM			Reviewed by Supervisor	07/14/2015 12:00:00 AM	ADDRESS	34.03869	-118.43767	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV2, INSTALL 3900 KWDC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE WITH THE MAIN SERVICE PANEL.(150) MODULES: KYOCERA KD260GX-LFB2 260W(4) INVERTERS : SOLAREDGE SSE9K-US>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
432	18041-10000-23362	591 N IRVING BLVD	90004	4	141B189   663	5523030021	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.08149	-118.31884	PC FOR ROOF MOUNTED PV IN SFD. SYSTEM SIZE 5.25 KWDC/ 5.2 KWACSCOPE INCLUDES 17 MODULES AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
433	10041-20000-07900	1999 S AVENUE OF THE STARS #250	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	05/03/2010 12:00:00 AM		Permit Finaled	07/08/2010 12:00:00 AM	ADDRESS	34.05886	-118.41642	energy plan check suite # 250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
434	17041-20000-10682	1018 S DODSON AVE	90732	15	015B193   927	7560022004	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.73443	-118.31173	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (36) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
435	13041-10000-32672	735 S FIGUEROA ST #204	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	FIRST TIME TENANT. PLAN CHEK FOR POWER AND ENERGY.  AREA 972 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
436	15041-10000-23851	507 W 83RD ST	90044	8	099B201  1388	6032021031	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Apartment			07/24/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	33.96331	-118.28317	(N) 83-device fire alarm system for new 3-story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
437	17041-20000-45164	2465 S PURDUE AVE	90064	11	123B153   597	4260037013	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			12/15/2017 12:00:00 AM	02/25/2020 12:00:00 AM		Permit Finaled	01/05/2022 12:00:00 AM	ADDRESS	34.03253	-118.43959	1200A 240/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
438	14041-10000-27356	12816 W HORTENSE ST	91604	2	168B161   801	2362019006	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	34.15479	-118.41233	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5 KW. STANDARD CENTRAL INVERTER PLAN.(23) KYOCERA KD255GX(1) SOLAREDGE SE5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
439	19041-10000-04252	2968 W 7TH ST	90005	1	132B197   215	5077016027	C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	07/18/2022 12:00:00 AM	PIN	34.05946197	-118.28769722	Full plan check for power and energy. New 7 Story Mixed Used. Apartments and 1st floor retail and restaurant. New electrical service, distribution panels, circuits and lighitng. Total sq. ft. 212,241.Bulding Permit: 18010-10000-05557	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
440	16041-10000-08483	10215 N SCOVILLE AVE	91040	7	204B189   888	2560025013	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.25475	-118.31413	pv1 sfd total system size 5.8kw ac using 27 modules. using microinverter system. enphase m215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
441	10041-30000-11583	11845 W OLYMPIC BLVD Suite #600	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	08/27/2010 12:00:00 AM	PIN	34.03325831	-118.45191172	lighing and power in office area in suite #600. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
442	17041-20000-02175	6439 N NEDDY AVE	91307	12	180B089   854	2033002006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.18693	-118.65345	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.4.32W ungrounded system. (18) EnPhase M250 microinverters. (18) 285W pv modules. Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
443	15041-10000-16475	3033 W WILSHIRE BLVD	90010	10	135B197  1240	5077008018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.06198	-118.28733	NEW FA SYSTEM FOR NEW APARTMENT BUILDING WITH 4 LEVEL PARKING LOT, HIGH RISE, 18 STORIES + ROOF FLOOR. 1125 DEVICES PLUS 2 FA PANELS AND 3 ANNONCIATORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
444	11041-10000-16184	10250 W SANTA MONICA BLVD STE 1250	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	T24 lighting plan check for new bakery.  Existing original permit.  Contractor required to obtain supplemental permit # 11041-10001-15255.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
445	14041-10001-06389	6051 N CARTWRIGHT AVE	91606	2	177B177   476	2414014002	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.1809	-118.36389	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U (10)MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
446	15041-10004-35073	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	CHANGE TO APPROVED SET. CHANGES NOTED DELTA 37 ON PLANS. Changes are clouded on the plan.Changes includes minor notation modification for contractor. All circits are existing on delta 36.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
447	19041-10000-16391	1100 E PICO BLVD	90021	14	123A211   312	5132017002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.03018	-118.24827	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
448	19041-20000-17875	17357 W BOSWELL PL pv1	91344	12	222B129    88	2602011030	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.3047	-118.51253	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
449	15041-20000-26167	18000 N BULL CANYON ROAD	91344	12	219B129   497	2601025029	A1-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	PIN	34.29519534	-118.52412828	Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
450	12041-20000-26287	5620 S MESMER AVE 1426	90230	11	105B165   299	4220015031	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM			PC Info Complete	11/01/2012 12:00:00 AM	ADDRESS	33.98511	-118.39992	Plan check for power only. Plan check per customer's request. Addition of a 15kVA UPS, two panels, and 17 branch circuits. Kaiser.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
451	18041-10000-10182	9301 N WINNETKA AVE	91311	12	198B113   122	2748038032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.23934	-118.57134	PC FOR NEW FA SYSTEM IN 2 STORY BUILDING. SCOPE INCLUDES 2 PANELS AND 305 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
452	15041-10000-08578	6600 N TOPANGA CANYON BLVD # 1062	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	CHANGE OF USE AND TENANT IMPROVEMENT OF An  ISLANDS RESTAURANT WITH BAR/LOUNGE AT THE FIRST LEVEL OF THE WESTFIELD TOPANGA MALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
453	11041-20000-14750	13421 W VAUGHN ST	91340	7	213B157   435	2523013902	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	ADDRESS	34.27983	-118.4252	solar system 38.6 kw for school	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
454	19041-10000-36352	10842 W VICTORY BLVD	91606	2	180B173   876	2414008004	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Apartment			09/12/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	04/05/2024 12:00:00 AM	ADDRESS	34.18641	-118.36745	"FULL PLAN CHECK FOR A NEW 4 STORY, 6 UNIT APARTMENT BUILDING. SCOPE INCLUDES NEW 600A SERVICE 240/120V 3� 4W. TOTAL AFFECTED AREA IS 5531 SQ.FT B#15010-10000-04022FIRE VARIENCE SUBMITTED TO SEPERATE FA PLANS""COMPLY WITH DEPARTMENT ORDER effective date 09/11/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
455	14041-10001-07619	18021 W CHATSWORTH ST #16	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.26491	-118.52556	(((4/4/2014- CHANGES MADE TO APPROVED SET OF PLANS. DELTA ONE CHANGES. REVISE LIGHTING LOAD. T24 CALCULATIONS TO BE VERIFIED)))PLANCHECK FOR T24 ENERGY. Tenant Improvement for existing retail space. 4250 SQFT, EMERGENCY LIGHTING. NEWLY CONNECTED LOAD <400 AMPS. NO CHANGE IN OCCUPANCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
456	17041-20001-07000	8621 N PENFIELD AVE	91306	3	192B113   739	2782011***	(T)(Q)RD4-1XL	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM			PC Approved	03/13/2017 12:00:00 AM	ADDRESS	34.22669	-118.56904	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (18) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
457	17041-10000-03775	14300 W SHERMAN WAY	91405	6	183B153   134	2217006061	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.20099	-118.44464	FULL PC FOR POWER AND ENERGY FOR AN EXISTING CHURCH SANTUARY. SCOPE INCLUDES ADDING NEW CIRCUITS, NEW LIGHTS, ONE NEW ATS, AND RECEPTACLES. A OCCUYPANT LOAD > 100. TOTAL AFFECTED AREA IS 18061 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
458	17041-20000-01631	23381 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	01/23/2017 12:00:00 AM		Issued	01/23/2017 12:00:00 AM	ADDRESS	34.15887	-118.63415	Plan check for power only. Project site is an existing commercial building. Project scope is the addition of a new 600-amp meter main and distribution board for a new tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
459	10041-10000-21735	7015 W MELROSE AVE	90038	5	141B181   584	5525008006	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM			PC Approved	11/05/2010 12:00:00 AM	ADDRESS	34.08357	-118.34329	T-24 and emergency lighting plan check for restored restuarant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
460	18041-10002-01272	2015 S GREENFIELD AVE	90025	5	126B153   250	4323015022	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Issued	02/20/2018 12:00:00 AM	ADDRESS	34.0441	-118.43749	SUPPLIMENTAL FOR THE 3 ENERGY STORAGE SYSTEMS (TESLA POWERWALL 5.8KVA/13.5KWH)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
461	17041-10000-11390	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.10222	-118.32701	FULL PLAN CHECK INTERIOR AND EXTERIOR RENOVATION FROM GROUND FLOOR (1) TO ROOF (6) FOR EXISTING  HOTEL, NO CHANGE IN USE. EXISTING 2000 AMP SERVICE 120/208V 3PHASE 4WIRE. NEW DISTRIBUTION BOARDS BEING ADDED, NEW PANELS. 5 TYPICAL UNITS. NEW INDOOR/OUTDOOR LIGHTING. PANELS. AREA: 36,440. BLDG # 17016-10000-08652.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
462	17041-10000-45833	6330 N LAUREL CANYON BLVD	91606	2	180B165   800	2334003069	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.18575	-118.39631	Plan  check for new fire alarm system for Adult Day Health Care Center with 48 devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
463	13041-10000-09389	5450 W PICO BLVD SUITE 103	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.04862	-118.35714	TI FOR RETAIL SPACE.  T24 PLAN CHECK ONLY.  2065 SQ FT.  2 STORY BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
464	10041-20001-08869	4425 S CENTRAL AVE	90011	9	112-5A209 121	5108028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.00306	-118.25677	Plan check power and energy. Service upgrade from 600A to 1000A service. New electrical eqipment, panels, and ckts installed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
465	10041-10000-22790	1467 W SUNSET BLVD	90026	13	139-5A209 293	5406001044	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.07552	-118.25402	NEW CONVENIENCE STORE   WITH EXISTING GASOLINE DISPENSERS. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
466	16041-20000-14351	9340 N PENFIELD AVE	91311	12	198B113    95	2761040017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.24067	-118.56948	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 14896.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
467	17041-10000-27442	11630 N INDIAN HILLS ROAD	91345	7	213B149   135	2664023030	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.28192	-118.4587	REMOVE METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES- T24 ONLY. TOTAL SQAURE FT 22400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
468	18041-20000-24941	21550 W OXNARD ST Suite 600	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 only. Project site is an existing suite on the 6th floor of a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 5,885 sq. ft. Note: Building application has been generated under 18016-10000-20832	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
469	13041-10000-29423	5345 N ARGUS DR	90041	14	165A225   102	5669003007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.14462	-118.20683	Permit to be pulled over the counter. PV1.  Install 6.25 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE6000A-US.  25 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
470	17041-20000-17649	12100 W OLYMPIC BLVD #400	90064	11	123B149   575	4259025019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.03215	-118.45396	Plan check for energy only. TI to existing office space, suite #400. New lighting (incl. emergency). 2,886.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
471	14041-10000-20333	4848 N ALCOVE AVE	91607	4	168B161   295	2357019015	R1-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.15923	-118.41258	roof mounted solar. System size = 6.63 kw. 1 inverter 6000watts. 26 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
472	16041-10000-02639	9220 N WINNETKA AVE	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM			PC Info Complete	04/21/2016 12:00:00 AM	ADDRESS	34.23795	-118.57084	New Fire alarm system on 4 story office building. (1) comm. panel, (1) fire alarm panels, (1) control (341) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
473	10041-10000-25863	14006 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	INSTALLATION OF  A 705 KW PHOTOVOLTAIC  SYSTEM ON THE ROOF OF THE FASHION SQUARE MALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
474	16041-30000-29025	3741 W STOCKER ST 1st FL	90008	8	114B185   781	5032022005	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.00639	-118.33838	Plan check Title 24 only in existing space T.I. in multiple tenant suite # 100,104,106,108,109 & 110 . Total area: 7,215 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
475	18041-10000-31327	900 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Issued	02/11/2019 12:00:00 AM	ADDRESS	34.04526	-118.26611	PLAN CHECK FOR T24 ONLY, MINOR RENOVATION OF GROUND FLOOR MAIN RECEPTION / LOBBY LEVEL 01, LOBBY LEVEL 26, AND CORRIDORS (TYPICAL FOR LEVEL 27 THROUGH 52)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
476	19041-20001-36643	6240 N RANDI AVE	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18396	-118.61008	Expedite per applicant requst Plan check for PV roof mounted system, System size: 25.230KW DC, 22.5KW AC with 58 PV Modules and 2 inverter(14.4KW and 9.0KW )Applicant request: %%%%%%    Plan stay Van Nuys  %%%%%%%%Note: This is 12 buildings on 1 Plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
477	17041-20002-37841	1333 N SIERRA BONITA AVE	90046	4	147B177  1376	5550027012	R3-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Apartment			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.09531	-118.35409	Revisions to approved set of plans.  Change of service entrance conductor detail, reconfiguration of service equipment/distribution.  (((Plan check for power and energy. New 4-story, 6-unit apartment building above one level subtarranean parking. 600A service.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
478	18041-10000-38963	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.06664	-118.46903	NEW FIRE ALARM SYSTEM IN A SCHOOL WITH 641 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
479	10041-10004-24337	512 E ROSE AVE	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			03/06/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	03/28/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	Plan check for supplemental to approved plans. LADWP providing two services to building. 2000A service for commercial and 2500A service for residential. Includes new switchboard. Air condtion load in dwelling units revise. Verify fault current calculation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
480	18041-10000-26938	134 N AVENUE 61	90042	1	153A229   339	5492014022	[Q]C4-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.20	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.11234	-118.189	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
481	16041-10000-23599	3686 E OLYMPIC BLVD	90023	14	118-5A227 222	5191025012	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.01867	-118.19685	Installation of solar system in a commercial site, roof mounted. Installing three different inverter systems. System 2: (3) Central inverters rated at 33.3 kW (SOLAR EDGE, SE33.3KUS) each for a total size of 99.9 kW.  Installing (378) solar modueles. Note: System 1 and System 3 will be plan checked  under seperate permits.System 1 app # 16041-10000-23590System 3 app # 16041-10000-23604	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
482	10041-20000-14092	333 S GRAND AVE 47th fl	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM	09/03/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.05271	-118.25179	energy plan check conference room 47th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
483	17041-10000-00549	719 E 25TH ST A	90011	9	120A209   250	5131023022	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Apartment			01/06/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.02228	-118.26008	Plan check for PV roof mounted system. System size: 2.5kW with 8 modules and 1 inverter.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
484	13041-10000-35896	6600 N TOPANGA CANYON BLVD STE #51	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	TITLE 24 PART 6 ENERGY FOR (E) CHEESECAKE FACTORY; PROVIDING ELECTRIC LOW VOLTAGE FOR PATIO AREA. PROJECTED AREA IN LIGHTING WORK IS APPROX. 615 SQ FT. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
485	18041-10000-43501	4035 E GOODWIN AVE	90039	13	162B205   179	5593020007	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.13719	-118.27016	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
486	18041-10000-11276	361 N SALTAIR AVE	90049	11	135B141   155	4402016003	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.06878	-118.4747	NEW ACCESSORY LIVING QUARTERS.- POOL HOUSE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
487	12041-10000-19507	715 W 3RD ST	90012	9	132A211    47	5151014033	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Finaled	03/05/2013 12:00:00 AM	PIN	34.0545108	-118.25249769	PLAN CHECK T24 ENERGY FOR OFFICE TI. PERMIT FOR NEW PANEL, EQUIPMENT, AND BRANCH CIRCUITS TO EXISTING SERVICE. LESS THAN 400A LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
488	10041-10000-08360	1289 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.05103	-118.22529	PV system for an appartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
489	16041-10000-32713	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	PIN	34.04222127	-118.45848597	NEW FA SYSTEM FOR APARTMENTS. TOTAL OF 697 DEVICES AND 20 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
490	16041-30000-28611	2029 S CENTURY PARK EAST 17th Floor-Restroom	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check Title 24 only in existing high-rise men and women restroom on 17th floor. Total lighting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
491	19041-10001-18636	144 N BRISTOL AVE	90049	11	132B137   341	4405020007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.05794	-118.48823	FEE EXPEDITEPLAN CHECK FOR A ROOF MOUNTED 11.34KVA PV SYSTEM CONSISTING OF 36 (SUNPOWER X22-370) AC MODULES CONNECTED TO EXISTING 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
492	19041-20000-30449	12740 W HANOVER ST	90049	11	129B137   128	4405023016	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM			No Progress	08/11/2020 12:00:00 AM	ADDRESS	34.05286	-118.48591	Install new 600A 240/120V 1ph-3w service. Provide new panels and equipments. Permit fee paid under building permit 18010-30000-02869. Plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
493	19041-20000-14122	2556 N CANYON DR	90068	4	154-5A191 244	5580021002	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.1175	-118.31618	PV1.  Addition of 1.98 kW DC / 1.683 kW AC roof mounted grid tied PV system.  Existing 2.55 kW DC / 2.167 kW AC on site, interconnecting at same point in building wiring system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
494	15041-10000-14337	5200 N LANKERSHIM BLVD SUITE 370	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.16511	-118.37448	TI-24 TO AN (E) COMMERCIAL BUILDING. REPLACING EXISTING LIGHTING WITH RETROFIT KITS. TOTAL SQ. FT. 2514. SCOPE OF WORK TO BE PERFORMED IN SUITE 370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
495	17041-20000-34764	10155 N CASABA AVE	91311	12	204B113   343	2741006003	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.25542	-118.5762	PV1. Install 10.32 kW roof mounted grid tied PV system.  (43) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
496	17041-20000-19682	15250 W VENTURA BLVD Suite 604	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.15351	-118.46549	Plan check for energy only. TI to existing office suite 604 in high rise building.New lighting (incl. emergency). 1,254sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
497	15041-10000-11509	303 S LINCOLN BLVD	90291	11	111B145   645	4240018050	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.00112	-118.4679	TI TO AN EXISTING SUNGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 2317	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
498	13041-10000-32396	221 E 58TH ST	90011	9	108B205  1020	5101020006	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	33.98993	-118.2711	change of use  from a factory to a garageplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
499	09041-20005-20042	137 N SOTO ST	90033	14	127-5A223  76	5183005019	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.20	Electrical	Electrical	Apartment			06/17/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.04482	-118.20939	incorporate changes on plan requested by inspector	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
500	17041-20001-45328	4342 N TALOFA AVE	91602	4	165B181   222	2424025003	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.14984	-118.35132	expeditepv1install roof mounted pv system sized 11.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
501	12041-10000-16238	5842 S VERMONT AVE	90044	9	108B197  1673	6004001023	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	33.98793	-118.29128	Change to lighting and receptacles to an existing retail space. Load is less than 200Amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
502	19041-10000-39216	1818 W 81ST ST	90047	8	099B193  1197	6035009022	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM			Verifications in Progress	12/20/2019 12:00:00 AM	ADDRESS	33.96537	-118.3098	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10KWac/7.32KWdc. SCOPE OF WORK IS 24 MODULES (HANWAH CELL 305W) WITH OPTIMZERS (SEP320) LEAADING TO A CENTRAL INVERTER (SE10000H-US), INTERCONNECTING WITH AN EXISTING 400A MAIN SERVICE PANEL). NOTE STAMPS DO NOT CONTAIN STAMP AND SIGNATURE OF CONTRACTOR	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
503	18041-30000-26571	6922 W HOLLYWOOD BLVD 7TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLAN CHECK FOR T24 ONLY, RESTROOM RENOVATION ON THE 7TH FLOOR. APPROX 367 SF TOTAL. PROVIDING NEW LIGHTING AND RECEPTACLES, CIRCUITS ARE FED FROM EXISTING PANELS.(B# 18016-10000-07366)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
504	14041-20001-13633	7951 N HESPERIA AVE	91335	12	189B125   403	2101023013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.21524	-118.52644	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 6.885kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(27) Trina Solar #TSM-255PA05.18 pv modules(27) SolarEdge #P300 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
505	18041-10000-37983	1645 W SEPULVEDA BLVD	90501	15	045B193   440	7347017025	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	33.81672	-118.30758	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
506	18041-10000-28797	6171 N SEPULVEDA BLVD #A-3	91411	6	177B145   355	2242001026	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.18246	-118.46651	"NEW ""FIREHOUSE SUB"" RESTAURANT. FIRST TIME TENANT. PLAN CHECK FOR POWER AND ENERGY. 1292 SQR FT.BLDG PERMIT: 18016-10000-24411"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
507	17041-10002-39398	189 S THE GROVE DR Q10-A	90036	4	138B177  1132	5512003042	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	34.07125	-118.35662	[Plan check only, permit is covered under master # 17041-10000-39398] 2nd revision to approved plan, noted as Delta-4, SOW: relocate receptacle and tele/data outlet and rear sales area wall for dispaly lightings, revise lightng switch bank detail, and revise panel schedule to reflect changes to receptacles. <<<PC FOR CHANGES TO APPROVED SET TO REFLECT LIGHTING CHANGES. SCOPE INCLUDES CHANGES TO FIXTURES AND REVISION TO T-24 FORMS. THIS IS PLAN CHECK ONLY!PERMIT UNDER MASTER. T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN AN EXISTING MERCANTILE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 598 SQ. FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
508	18041-20000-35301	4532 N WESTCHESTER DR	91364	3	166-5A111  15	2174016034	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.15237	-118.58225	Plan check for a PV1 roof-mounted PV system. System size is 16.6 kWdc/15.3 kWac-CEC and consists of (2) inverters, (52) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
509	17041-10002-15276	10250 W SANTA MONICA BLVD #1970	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	2nd revision to approved plan. This is Plan check only, changes noted as Delta-7&8, scope is to revise light fix. type and wattage and T24 calc.  Permit is covered under master 17041-10000-15276	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
510	12041-10000-25487	555 S FLOWER ST 4th Floor	90071	9	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI IN AN EXISTING OFFICE AREA ON THE 4TH FLOOR. PLAN CHECK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
511	15041-10000-19989	1553 S WESTWOOD BLVD	90024	5	129B153    95	4324026029	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	34.05311	-118.44012	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 860.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
512	15041-10000-43743	11209 W RICHLAND AVE 1-13	90064	5	123B153   510	4256012001	R3-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Apartment			12/29/2015 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.03288	-118.43303	NEW 13 UNIT APARTMENT. PC FOR POWER AND ENERGY. FIRE ALARM VARIANCE MUST BE FILED. APPLICANT WILL FILE DURING PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
513	13041-20001-23736	6041 N ROD AVE	91367	3	177B085   325	2032020013	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.18065	-118.66218	pv1 single family dwelling using 6kw ac using 32 modules. transformerless inverter nonstandard plan. 4 strings/inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
514	14041-10012-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	Revision to approved set on delta-33: Changes include adding future projected load on plans for future retail space. Showing future panel ELA40LD4 on single line diagram.  Plan check only, no permit is needed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
515	18041-20000-00613	3617 N HOLBORO DR	90027	4	154-5A203 234	5592007050	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.11696	-118.27676	Install 54 kWh energy storage system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
516	13041-20000-34063	11442 W VICTORY BLVD	91606	2	180B169  1159	2335021011	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Issued	12/06/2013 12:00:00 AM	ADDRESS	34.18641	-118.38048	PV1 SINLGE FAMILY DWELLING. USING 12 MODULES. ENPHASE MICROINVERTER M215. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
517	18041-10000-04570	800 S LA BREA AVE	90036	4	132B181   271	5084003001	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	06/26/2020 12:00:00 AM	ADDRESS	34.06027	-118.34454	Full plan check for change of use on (E) Historic Building. Change of use from autoshop to microbrewery.  New service at 800A, new panelboards, total area under the scope: 9,845 sq.ft B#18016-10000-05359.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
518	18041-10000-00169	555 W 5TH ST 14TH FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR OFFICE TI. IN A HIGH RISE ON THE 14TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTRED AREA 959 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
519	10041-10000-21150	251 S OLIVE ST	90012	9	130-5A211  13	5149010035	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.05278	-118.24998	T-24 and Emergency lighting plan check in highrise hotel.  Add additional lighting for confrence rooms and corridors.  Emergency lighting has not been defined on the plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
520	19041-10002-25603	8545 N HATILLO AVE	91306	3	192B113    95	2782016011	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.22574	-118.56523	PLAN CHECK ONLY. CHANGES TO APPROVED SET. RELOATING EQUIPMENT AND ADJUSTING PLANS TO MATCH EXISTING/INSTALLED CONDITIONS. NEW 200A PANEL WITH 150A BREAKER IS COVERED UNDER EXPRESS PERMIT FOR PANEL UPGRADE. ((((PC FOR PV-1 , 49 MODULES WITH MICROINVERTERS, 1 GENERTOR 22KW, TRANSFER SWITCH. SYSTEM SIZE IS 16.660KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
521	17041-10003-19121	802 E E ST	90810	15	030B209  1214	7424015061	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	PIN	33.77558988	-118.25229481	"Supplemental application for change in word description. Scope of work includes new 1600A 480/277V distribution board ""D"" fed from upstream 5000A main switchboard ""B"" which is under permit 16041-10000-29461. 1600A distribution board to be energized by 5000A switchboard when DWPprovides service to 5000A switchboard."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
522	18041-20001-43427	5245 W SANTA MONICA BLVD	90029	13	144B193   695	5537009036	C2-1D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.09094	-118.30401	Expedited plan check fee. PV3.  Install 14.4 kW roof mounted grid tied PV system connecting to (E) 3000A 208Y/120V 3ph-4w service.  (40) modules with 14.4 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
523	14041-10000-35539	322 N NORTON AVE	90004	4	138B189   317	5522027011	R1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.07687	-118.31689	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac. System consists of (10) modules and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
524	18041-20000-13036	17551 W MARGATE ST	91316	5	171B129    54	2257003041	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.16774	-118.5159	PV1.  Install 6.67 kW DC roof mounted grid tied PV system with (23) modules and 7.6 kW rated string inverter.  Interconnecting with (E) 15.2 kW PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
525	19041-10000-52808	4200 N RADFORD AVE	91604	2	165B169   370	2368001028	[Q]MR2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	04/18/2022 12:00:00 AM		Issued	04/18/2022 12:00:00 AM	ADDRESS	34.14736	-118.39192	POWER PLAN CHECK ONLY. SCOPE OF WORK INCLUDES EQUIPMENT, CIRCUITS, AND PANELS WITHIN A CLASSIFIED AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
526	18041-20000-32172	17237 W VENTURA BLVD #C	91316	5	171B133   679	2258012022	[Q]C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	03/11/2019 12:00:00 AM		Issued	03/11/2019 12:00:00 AM	ADDRESS	34.16084	-118.50848	Plan check for Title 24 only in existing restaurant T.I. Total area: 2996 sq ft. B#18016-20000-27193	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
527	11041-10000-14171	8480 W BEVERLY BLVD BLDG A	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	08/29/2012 12:00:00 AM	ADDRESS	34.07577	-118.37599	Existing Sport Chalet to be converted to a Target.  Plan check is for feedrs tapping into existing service swbd section to a wireway and from wireway to new 3000A swbd section with a 2000AT/3000AF circuit breaker. This will be the main for the power to the Target store. Tenant improvement will be on separate application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
528	18041-10001-41173	3430 S 8TH AVE	90018	10	120B189   865	5044016045	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	34.02465	-118.32583	Changes to an approved set of plans. Changes include the removal of (1) module and change to System DC size. Total sytem size 2.52KWDC/ 3.8KWAC _________________NEW 2.835KW ROOF MOUNTED PV SYSTEM WITH 9 PV PANELS ON ATHE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
529	16041-10000-32532	8465 N CRANFORD AVE	91352	6	192B165   270	2634040020	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.22454	-118.4004	PV1. NEW SOLAR SSYTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.2KWac.(54)MODULES-KYOCERA #KU2656ZPA(2)INVERTERS-DELTA #SOLIVIA 6.6 TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
530	18041-10000-23611	355 S GRAND AVE #2000-2100	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PC FOR POWER AND ENERGY, SCOPE OF WORK INCLUDES OFFICE TI IN A HIGH RISE BUILDING, 20TH AND 21ST FLOOR. NEW LIGHTING AND CIRCUITS. TOTAL CONNECTED LOAD > 400AMPS, TOTAL SQ. FT. 28,616.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
531	13041-20000-19758	1900 S LINCOLN BLVD	90291	11	108B149    31	4242006001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	33.9961	-118.45652	new restaurant. pc for power and energy. place of assembly. 600a service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
532	18041-20000-14648	20060 W PRAIRIE ST	91311	12	198B113   222	2761001***	(T)(Q)CM-1-MPR, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Apartment			04/20/2018 12:00:00 AM			PC Info Complete	05/04/2018 12:00:00 AM	ADDRESS	34.239	-118.57029	Plan check for a fire alarm for a 6-story apartment building. Fire alarm consists of (1) FACP, (12) RPSs, (1) annunciator, and (505) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
533	17041-20000-42714	515 S FIGUEROA ST 7th flr	90071	5	123B161   995	4314022041	C2-1	West Los Angeles	West Los Angeles			2699.04	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
534	17041-20000-21293	18220 W SHERMAN WAY	91335	3	183B125   217	2125036021	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.20092	-118.5303	NEW 2 STORY SCHOOL 800 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
535	15041-10000-33053	9254 N WINNETKA AVE BLDG C	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Closed	08/10/2021 12:00:00 AM	ADDRESS	34.23884	-118.57087	NEW MIX USE 5 STORY BUILDING WITH 188 RESIDENTIAL UNITS. BEING FED FROM EXISTING SERVICE THROUGH A 1600AMP, 4160V MEDIUM VOLTAGE SWITCHGEAR.(BUILDING PERMIT UNDER 15010-10000-02015: PROPOSED 5-STORY APARTMENT/RETAIL/RESTAURANT/PARKING BLDG.  (4 STORY TYPE VA OVER 1 STORY TYPE 1A. (25% PDPP ZONING PLAN CHECK ONLY - NO DAD, GREEN, FIRE LIFE SAFETY, OR STRUCTURAL))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
536	14041-20001-21838	5420 N YOLANDA AVE	91356	3	174B121   813	2161026004	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			02/02/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.16939	-118.54034	2.2.2015 - Plan check for modifications to approved set. Relocate meter bank MB2, adjust feeder sizes to compensate for different voltage drops/fault currents to unit panels. Delta 1A changes.[57  units Condo over Type I-A Garage.Fire alarm variance filed.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
537	15041-20000-16318	936 S OLIVE ST UNIT 348	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #17 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
538	12041-10000-04628	601 S WESTERN AVE	90005	10	135B193   894	5503031007	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM			PC Info Complete	06/28/2012 12:00:00 AM	ADDRESS	34.06328	-118.30927	"New service, main switchboard and panels for an existing mixed-use comercial/residential building on the corner of 6th St and Western Ave.   TENANT SPACES ARE MARKED AS ""FUTURE"", LOADS ARE NOT KNOWN AND WILL REQUIRE FULL PLAN CHECK WHEN TENANT DOES IMPROVEMENTS.Main switchboard is at address 601 S. Western Ave #101.  Sub-panels are at address 601, 603, 605 Western Ave, and 3956, 3956 1/2, 3958, 3960, 3962, W. 6th St. and 3950 W. 6th St Suites 301-414."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
539	12041-20000-14905	6303 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	ADDRESS	34.18474	-118.60182	T24 lighting plan check for a minor alteration to an existing lighting system which was presented as adding only two lights to suite 118 which is part of the employee cafeteria on the first floor of the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
540	14041-10002-32844	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.07583	-118.37407	Minor revisions to approved set.  Change of lighting fixture and relocation of fixtures.  Delta 7 revisions.(((T24 and power plan check.  Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects. Area = 1849 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
541	16041-10000-30277	636 S MARIPOSA AVE	90010	10	135B197  1222	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	PIN	34.06223337	-118.29881302	CHANGE OF USE FROM EXISITING OFFICE TO  ART GALLERY WITH BAR (1402SQFT). (original application was for art gallery)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
542	13041-10001-24745	15717 W HIAWATHA ST	91344	12	204B141    68	2661010010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.25926	-118.47445	EXPEDITED PER APPLICANTS REQUEST.PV1. INSTALL 4.9 KW DC ROOF MOUNTED SOLAR ARRAY OF 20 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
543	18041-10000-41900	12714 S FIGUEROA ST 1-10	90061	15	081B201   236	6132019048	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Apartment			11/01/2018 12:00:00 AM	07/18/2022 12:00:00 AM		Issued	07/18/2022 12:00:00 AM	ADDRESS	33.9173	-118.28262	FULL PC FOR (N) 3 STORY (10) UNIT APARTMENT WITH ELEVATOR, 1 (N) 600A SERVICE10 TYPICAL UNITS, 2 TYPES, 5 OF EACHBLDG PERMIT #: 18010-10000-02302	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
544	11041-20000-25805	8732 S SEPULVEDA BLVD Unit A	90045	11	096B165   851	4123002004	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	33.95785	-118.39597	Existing bagle shop.  Adding additional panels and additional circuits.  Total new load exceeds 400 AMPS.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
545	18041-20001-18499	19520 W STRATHERN ST	91335	3	189B117   370	2105005020	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	34.2155	-118.55892	09-21-2018 Changes to an approved set of plan, Changes include update conductor size to 10AWG, calculation is provided, update location of inverters and main panels location. Changes has been clouded.California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
546	16041-20000-14095	21777 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.16858	-118.60238	Plan check for power only.  Project site is an existing commercial building.  Project scope is a new 1200-amp service to replace fire-damaged service equipment like-for-like.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
547	15041-10001-05245	19550 W NORDHOFF ST	91324	12	195B117     9	2783028062	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM			PC Info Complete	10/29/2015 12:00:00 AM	ADDRESS	34.23529	-118.55947	Change to approved set, by relocating the equipment for the car wash building, new panels added, lighting plan also being modified. All changes are under delta-2 only.(((A new car wash building supplied from outdoor feeder; total area is 1304 SQ feet.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
548	19041-10000-31748	7459 N TAMPA AVE	91335	3	186B117   421	2116016001	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.20628	-118.55373	New fire alarm system consisting of a new fire alarm panel and 42 FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
549	15041-10000-11321	200 S AVENUE 66	90042	14	153A233   285	5492039014	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM			Reviewed by Supervisor	04/27/2015 12:00:00 AM	ADDRESS	34.11302	-118.18001	NEW SWITCHGEAR 800AMPS.  RECONNECTING TO EXISTING LOADS.  PLAN CHECK FOR POWER ONLY NO LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
550	09041-10009-08059	6250 W HOLLYWOOD BLVD	90028		148-5A189 132	5546029917	C4-2D-SN		Hollywood	Central Hollywood			Electrical	Electrical	Commercial			01/25/2010 12:00:00 AM			PC Approved	01/25/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	Remove the dishwasher rinse and a motor and connect some lights on emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
551	15041-10000-44013	2531 N SILVER LAKE TER	90039	4	150A207   323	5439020014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.10391	-118.26161	PERMIT FEE $0.00 BY STAET SENATE BILL NO. 1222PV1 installation to a single family home. (2) Inverters total rating: 11kw, (47) solar modules, Load center 100 amps.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
552	14041-10000-09441	2053 W VENICE BLVD	90006	10	126B193   221	5075013019	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.04374	-118.30174	T24 FOR EXISTING DOLLAR TREE GROCERY STORE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400AMPS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
553	14041-20000-27697	21550 W OXNARD ST SUITE 630	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.179	-118.60001	PC FOR TI TO SUITE 630. NEW LIGHTING AND NEW PARTITIONS. T24 ENERGY ONLY. TOTAL AREA 4248 SQ FT,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
554	13041-10000-06177	14429 W ROSCOE BLVD	91402	6	192B149   366	2638022045	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM			PC Info Complete	03/08/2013 12:00:00 AM	ADDRESS	34.22174	-118.44762	"TI IN AN EXISTING ""EL POLLO LOCO"".  PLAN CHECK FOR T-24 ENERGY CALCS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
555	16041-10000-10012	15416 W LASSEN ST	91343	7	201B145   645	2656003014	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.24986	-118.46828	CHANGE OF USE FROM ARCADE TO A (NEW) COIN LAUNDRY.  NEW 400MS. TOTAL AREA: 1,950 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
556	14041-10000-24758	380 WORLD WAY Space 89	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	10/23/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 plan check only.  Total area = 24 sq. ft.TI to airport terminal kiosk.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
557	14041-10001-35150	605 W BOCCACCIO AVE # A	90291	11	108B149  1432	4237006053	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	PIN	33.98921587	-118.45798338	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 4.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: YINGLY YL255P-29b(1) INVERTER: ABB PV1-3.6-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
558	17041-10000-02747	6514 W SANTA MONICA BLVD	90038	13	144B185   749	5533013002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.09057	-118.33159	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURE WITH NEW LED FIXTURES FOR EXTERIOR/INTERIOR USE. TOTAL AFFECTED AREA IS 23550 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
559	15041-20000-43209	3434 S GRAND AVE	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.01912	-118.27658	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE/STORAGE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1235 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
560	17041-20000-04138	5750 W WILSHIRE BLVD Suite 600	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	Plan check for Title 24 only. Project site is a suite within an existing building. Project scope is a change of use from office to theater/tenant improvement. Total lighting area = 1,535 sq. ft.Note: Building application has been generated under 17016-10000-02708	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
561	11041-20001-00535	2750 W RIVERSIDE DR	90039	4	151-5A207 105	5438024021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Approved	06/21/2011 12:00:00 AM	ADDRESS	34.10876	-118.26115	Revision to approved plans. Changes to  point of connection from supply side to load side, derate main breaker from 400A to 200A, and modules from 230W to 235W.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
562	19041-10000-17594	5800 S CENTRAL AVE	90011	9	108B209  1381	5104031011	MR1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.99002	-118.25625	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
563	18041-20000-17667	11601 W WILSHIRE BLVD STE 480	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing space T.I. office space. Total area: 1917 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
564	11041-10000-00377	20140 W SHERMAN WAY Building A	91306	3	183B113    63	2135038015	(T)(Q)C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			PC Info Complete	04/14/2011 12:00:00 AM	ADDRESS	34.20085	-118.57213	general/emergency lighting for retail space of existing Public Storage building A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
565	10041-10000-00361	333 S GRAND AVE #1950	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/08/2010 12:00:00 AM			PC Info Complete	01/08/2010 12:00:00 AM	ADDRESS	34.05271	-118.25179	T.I for a high rise building 19th floor.  Install general and emergency lightings.  Permit under 10041-10000-00298.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
566	12041-10000-28460	12301 W PICO BLVD	90064	11	120B149    64	4259028011	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Apartment			11/27/2012 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.02858	-118.45242	FIRE ALARM FOR 5 STORY 90 UNIT APT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
567	06041-20005-03444	10844-10852 W LINDBROOK DR	90024	5	132B153   242	4360003015	C4-2D-O	West Los Angeles	Westwood			2652.02	Electrical	Electrical	Apartment			12/19/2012 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.06013	-118.44228	CHANGES TO APPROVED PLANS PERMIT # E06LA 00256	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
568	17041-10000-17908	5750 S MESMER AVE	90230	11	105B165   299	4220015038	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	33.98373	-118.39868	PC for energy only, Indoor title 24 TI to an auto dealership. Installing new led lighting. Area: 25117	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
569	19041-20001-34249	4730 N TOPEKA DR	91356	3	168B121   319	2176030025	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	10/21/2019 12:00:00 AM	ADDRESS	34.15596	-118.54733	PV1 EXPEDITED PV PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 14.4 KW. SCOPE OF WORK CONSISTS OF (40) PV MODULES WITH OPTIMIZERS, A 11.4 KW INVERTER, AND (2) BATTERIES TOTALING 27 KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
570	15041-10000-42339	2159 E BAY ST	90021	14	123A217   424	5166001002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.03156	-118.22794	T-24, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING FOR INDOOR AND OUTDOOR SPACES AND NEW RECEPTACLES. TOTAL SQ. FT. 9539.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
571	18041-20001-27273	2870 N BENEDICT CANYON DR	90210	5	156B153   181	4382007003	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.12276	-118.43482	07-31-2018 Changes to an approved set of plan. Changes include update Single Line Diagram to reflect 225 A Panel with 200A main Breaker. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
572	16041-20000-45836	8330 N RESEDA BLVD	91324	12	192B125   576	2786022026	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.22174	-118.53587	ti to an existing medical office building.  adding new 600amp board(1DB) to xisting switchboard(MS).  plan check for power and energy.building p# 16014-20000-06312	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
573	17041-20000-22208	5505 N BONNER AVE	91601	2	174B173  1265	2350005015	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.17022	-118.3742	INSTALLATION OF A NEW FIREALARM SYSTEM. 1 FACP AND 148 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
574	18041-20001-36702	7033 N RESEDA BLVD	91335	3	183B125   454	2126008009	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.19864	-118.53624	11/30/2018changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.  ((((pv2install roof mounted pv system sized 14KW AC interconnected with msp.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
575	18041-10000-13521	721 E 6TH ST	90021	14	126A213    77	5147020005	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.04097	-118.24283	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
576	16041-20000-26736	3060 W OLYMPIC BLVD	90006	10	129B193   321	5080030001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			07/28/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.05239	-118.30229	new fire alarm system 1 facp 312 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
577	19041-10000-34307	1018 N LAKME AVE	90744	15	033B209   902	7423018027	RD6-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	33.78361	-118.25945	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6 KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 21 MODULES USING P320 OPTIMIZERS AND ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
578	13041-20000-33198	218 W 5TH ST	90013	14	129A211   107	5149034011	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Info Complete	07/31/2014 12:00:00 AM	ADDRESS	34.04771	-118.25033	New service, elevators, generator, lighting and loads for an existing Historical building.  FULL PLAN CHECK for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
579	11041-20000-25865	12041 W WILSHIRE BLVD Ste #1	90049	11	126B145    53	4265016046	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM			PC Approved	12/07/2011 12:00:00 AM	PIN	34.04519158	-118.46671786	Existing office space (Suite # 1).  Adding light fixtures and new branch ckts.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
580	16041-10000-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	CHANGE OF USE OF OFFICE BUILDING TO HOTEL. FULL PLAN CHECK FOR POWER AND ENERGY. FULL 12 STORY TI. BUILDING IS HIGHRISEFIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
581	12041-20000-00575	19307 W SATICOY ST	91335	3	186B117  1034	2116014019	QC2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM			PC Approved	01/10/2012 12:00:00 AM	ADDRESS	34.20851	-118.55435	energy plan check albertson's market  revision only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
582	12041-10000-05570	1356 W ALLISON AVE	90026	1	138A211   119	5405021033	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM			PC Approved	03/13/2012 12:00:00 AM	ADDRESS	34.07275	-118.25157	T.I. to an existing restaurant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
583	16041-20001-36289	747 N LILLIAN WAY	90038	13	141B185   328	5533032022	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM			PC Approved	11/15/2019 12:00:00 AM	ADDRESS	34.08482	-118.32797	SUPPLEMENTAL FOR CHANGES TO APPROVED SET, CLOUDED DELTA 3 CHANGES ONLY, CHANGES TO EMERGENCY CIRCUIT, LIGHTING FLOOR PLAN, PANEL SCHEDULES, PHOTOMETRICS, LIGHT FIXTURE SCHEDULE, CUTSHEETS, AND T24 SHEETS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
584	10041-10003-22348	8378 W MELROSE AVE	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.08341	-118.37285	"Modification to approved plans, elevator circuit moved from HP to main switchboard. <<<<<TI in a retail. New service and panels. EPC for power and energy. CORE & SHELL ONLY.  COMPLETE PLAN CHECK WILL BE REQUIRED FOR EACH TENANT.  <<<<<<Methaen Buffer Zone Level 1 with less than 2"">>>>>>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
585	12041-20000-25823	2630 N HYPERION AVE 101	90039	4	150A205    96	5432001016	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM			PC Approved	10/29/2012 12:00:00 AM	PIN	34.10627783	-118.27222119	Plan check for energy and emergency lighting. Restaurant. 1183sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
586	14041-10000-25711	4039 N CODY ROAD	91403	4	165A147   279	2277013025	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.14436	-118.4639	Permit fee is 0.00 due to Senate bill 1222PV1, INSTALL 14.03 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(55) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
587	11041-20000-01763	2651 N NOTTINGHAM PL	90027	4	153B193   150	5588005019	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.00, 1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	34.1148	-118.30055	New 12.22 Kw roof mounted P.V. system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
588	13041-10001-22261	19948 W MAYALL ST	91311	12	204B113   502	2726002029	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	34.25351	-118.56831	�Expedited plan check per applicant request�.PV1 10.045KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-3.6-OUTD-US and PVI-4.2-OUTD-US] [( 41) MOD: TRINA {TSM-245PC05.18}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
589	18041-20000-08517	5240 N HERMOSA AVE	90041	14	163-5A225 160	5669023008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.14242	-118.20755	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (22) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
590	19041-10000-40340	1630 W 186TH ST	90248	15	060B193   248	6108002022	P-1VL, [Q]MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	07/27/2021 12:00:00 AM	ADDRESS	33.86187	-118.30705	CONVERSION OF TWO EXISTING ENGINE TEST CELLS FROM GASOLINE ENGINE TESTING TO A SINGLE HYDROGEN/ELECTRIC HYBRID POWERTRAIN TESTING. A SMALL EXPANSION WILL BE CONSTRUCTED ADJACENT TO THE CELL TO HOUSE THE TEST CELL SUPPORT EQUIPMENT. EXTENDED THE EXISTING MAIN SWITCHBOARD BY ADDING ANOTHER SWITCH BOARD TO IT THROUGHT A BUS AND UPGRADING THE MAIN TRANSFORMER SIZE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
591	18041-20000-33653	7120 N HAYVENHURST AVE	91406	6	183B137    95	2224017027	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.1997	-118.49221	PV.2  Installation of 137.6 kW carport mounted grid tied PV system.  (372) modules with (2) 10 kW and (6) 15 kW rated string inverters.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
592	14041-10000-02231	9301 N TAMPA AVE SPACE #55-#56	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			Corrections Issued	01/27/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	T24 PART 6 ENERGY FOR (E) RETAIL SPACE ('GAP' STORE) . SCOPE OF WORK < 400A. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
593	13041-10000-10946	11859 W WILSHIRE BLVD	90049	11	129B145   838	4265013041	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01, 2643.02	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	PIN	34.04733645	-118.46407025	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING FOR TENANT IMPROVEMENT ON AN EXISTING OFFICE BUILDING. WORK TO BE DONE ON SUITES 100  AND 101. NOTE: ALL TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
594	11041-10000-17375	1701 E CESAR E CHAVEZ AVE Ste 125	90033	14	130-5A221 204	5174007047	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.05126	-118.2173	T.I.  Suite # 125 is a medical office.  Examination only, no procedures are conducted.  Remodel of light fixtures.  Plan check is for energy only.  Items needed for permit have been inputed under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
595	10041-10000-21360	1436 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   369	5021002001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2316.00	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Expired	01/07/2013 12:00:00 AM	ADDRESS	34.01068	-118.30167	Ti in a hair salon. Plan check is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
596	14041-10000-34696	11040 W PICO BLVD	90064	5	126B153  1136	4256008021	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.03753	-118.43352	Fire alarm  system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
597	14041-20000-21919	16651 W DEVONSHIRE ST	91344	12	204B137  1057	2684004025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.25764	-118.49544	PV1.  Install 9.18 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
598	12041-20000-17972	6255 W SUNSET BLVD suite 1802	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.09815	-118.32564	energy plan check suite 1802	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
599	12041-10000-26549	5900 W WILSHIRE BLVD 600	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM			PC Approved	11/05/2012 12:00:00 AM	ADDRESS	34.06237	-118.35809	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT AT THE  6TH  FLOOR OF (E) HIGH RISE OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
600	13041-20000-22948	10239 N HELENDALE AVE	91042	7	204A197   104	2558031004	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.25529	-118.29648	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.15 KW USING 10 MODULES. ENPHASE MICROINVERTER. NONSTANDARD PLAN. PC REQUIRED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
601	17041-10000-20167	3360 E OPAL ST	90023	14	120A225   234	5190013032	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Issued	06/15/2017 12:00:00 AM	ADDRESS	34.02244	-118.20483	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
602	17041-30000-39785	1440 N ALTA VISTA BLVD	90046	4	147B181  1185	5548018040	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.09712	-118.34686	Plan check for Title 24 only in existing corridor for 1st, 2nd and 3th Floor. Total area: 3250 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
603	13041-10000-34778	8034 N LLOYD AVE	91605	2	189B157   240	2304021020	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Expired	08/03/2015 12:00:00 AM	ADDRESS	34.21701	-118.42057	PV1, ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING WITH (E) 200A MAIN PANEL. SYSTEM SIZE IS 6kW DC, WITH (24) MODULES, #TSM-250PA05.18, (24) OPTIMIZERS OP250, (1) SOLAREDGE INVERTER #SE6000A-US IN SINGLE STORY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
604	16041-10000-34411	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM			Reviewed by Supervisor	10/04/2016 12:00:00 AM	ADDRESS	34.25052	-118.51258	PV1. AN ADDITION TO AN ON EXISTING RESIDENTIAL PV SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. ADDING 13.8KWac TO AN EXISTING SOLAR SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING SOLAR ARRAYS IS 20.8KWac.(60)MODULES-REC SOLAR: REC275TP(1)INVERTER-SOLAREDGE 10000A-US(1)INVERTER-SOLAREDGE SE3800 ER-US(1)SUBPANEL-125A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
605	15041-20000-07144	13030 MESA VERDE WAY	91342	7	225B165    19	2580018156	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	PIN	34.31120672	-118.40409465	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 7.7kW. Ungrounded system. (30) 275W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
606	14041-20000-02220	13329 W MOORPARK ST	91423	4	165B157   295	2360013024	[Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.1505	-118.42345	PC FOR T24 ENERGY ONLY. NEW LIGHTING FOR FIRE DAMAGED BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
607	11041-10000-22837	3075 W WILSHIRE BLVD	90010	10	135B197  1198	5077009005	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20, 2122.04	Electrical	Electrical	Apartment			10/25/2011 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.06197	-118.28885	ADAPTIVE REUSE PROJECT; CHANGE OF USE FROM OFFICE TO APARTMENTS & RETAIL - INTERIOR ALTERATION -  NEW PARTITIONS, NEW BATHROOM, KITCHEN (9 STORY) ( PLAN CHK FEE NEEDS TO BE REVISED AT TIME OF PLAN REVIEW AND VARIANCE SUBMITTED TO SEPARATE THE FA PLANS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
608	16041-30000-14520	5340 W 102ND ST	90045	11	090B173   206	4129032007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	33.9435	-118.37386	Plan check for energy Title 24 only in existing space office T.I. Total area: 8,447 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
609	19041-10000-44556	744 S BEACON AVE	90017	1	130-5A205  72	5142016017	R4-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	34.0531	-118.27298	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
610	19041-10000-52927	1225 S WILTON PL	90019	10	129B189   849	5081023015	RE9-1-O-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	02/29/2020 12:00:00 AM	ADDRESS	34.04826	-118.31469	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 1 ENERGY STORAGE SYSTEM, 29 MODULES (PANASONIC 330 W), 29 MICROINVERTERS (IQ7X-96-2-US), 1 COMBINER BOX, AND 1 PANEL OF 200 AMPSSYSTEM SIZE: 9.57 KW DC; 9.135 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
611	15041-20000-06581	7303 N NESTLE AVE	91335	3	186B125   852	2119026005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Expired	03/30/2017 12:00:00 AM	ADDRESS	34.20321	-118.53079	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (29) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
612	11041-10001-08386	3115 S SEPULVEDA BLVD	90034	5	120B157   416	4251013001	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.02601	-118.42781	revised single line to show new 400A panel hp will supply all the rtu units; service remains the same; loads adusted(((((TENANT IMPROVEMENT FOR BIG LOTS RETAIL STORE. NEW 800 AMP SERVICE, NEW AC UNITS & NEW LIGHTING. EPC IS FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
613	13041-20000-35143	11821 N CLONLEE AVE	91344	12	216B137   513	2609005010	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.28492	-118.49711	PV1 TRANSOFRMERLESS SYSTEM. 3 STRINGS FOR 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
614	19041-10000-48146	384 WORLD WAY M-52	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/08/2022 12:00:00 AM		Permit Finaled	03/02/2023 12:00:00 AM	ADDRESS	33.94339	-118.40887	"FIRST TIME TENANT IN UNIT #M52 - COMMERCIAL / RETAIL SPACE IN TERMINAL ""MSC"" IN LAX. INSTALLING PANELS, CIRCUITS & LIGHTS.  PLAN CHECK FOR POWER & ENERGY. AFFECTED AREA: 1,088 SFT ***M52 - CHICKEN GUY!***"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
615	14041-10001-31727	5553 W HOLLYWOOD BLVD	90028	13	148-5A193 134	5544003049	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.1019	-118.31108	PROPOSED INTERIOR TENANT IMPROVEMENT TO (E) RETAIL SPACE.   NO CHANGE OF USE.PLAN CHK FOR POWERplan chk only permit and title 24 plan chk were on master plan	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
616	18041-10000-37276	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	PLAN CHECK FOR TITLE 24 ONLY - SCOPE OF PROJECT INCLUDES ALTERATIONS TO EXISTING LIGHTING SYSTEM FOR GOOGLE BUILDING - LIGHTING ALLOWANCE IS TAKEN FROM EXISTING PROJECT FOR BUILDING (16041-10003-29411)LIGHTING ONLY FOR FACADE - EGRESS ILLUMINATION IS NOT AFFECTED BY NEW WALL LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
617	13041-10001-26829	10250 W CONSTELLATION BLVD	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			Verifications in Progress	11/13/2013 12:00:00 AM	ADDRESS	34.05735	-118.41746	"""EXPEDITED PER APPLICANTS REQUEST""PV2.  NEW ROOF MOUNTED PHOTOVOLTAIC SYSTEM. SYSTEM SIZE 136,800 kW DC. 120,531 AC. TRANSFORMER LESS INVERTER. (456) ASTRONERGY CHSM6612P 300W MODULES(3) SNA SUNNY TRIPOWER 20000TL-US 20KW (480V)(2) SNA SUNNY TRIPOWER 15000TL-US 15KW (480V)(2) SNA SUNNY TRIPOWER 12TL-US 12KW (480V)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
618	19041-10000-48981	111 E UNIVERSAL HOLLYWOOD DR 11th fl	91608	4	162B177   624	2424044042	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.13855	-118.36112	new lighting in the restroom/corridor on the 11 th floor of office buildingPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
619	18041-20001-25628	4009 N VALLEY MEADOW ROAD	91436	5	162B141    22	2285021019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM			Reviewed by Supervisor	07/27/2018 12:00:00 AM	ADDRESS	34.14389	-118.48177	Expedite per applicant requestPlan check for PV roof mounted and battery back up system with PV system size: 12.8kW  ACwith 41 modules and 2 inverters(7.6KW AC and 5.2KW AC) and battery backup system size: 54KW AC with 4 Tesla battery PowerWall connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
620	17041-10000-21044	9244 N ZELZAH AVE	91325	12	198B129   270	2766004021	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.23865	-118.52301	Title 24 plan check.  Remove metal halide fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
621	14041-10000-18644	4499 W YOSEMITE WAY	90041	14	160-5A219 262	5683020003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Expired	08/16/2016 12:00:00 AM	PIN	34.1329506	-118.22472679	Install roof mounted solar PV system on existing residential building.  Total system size = 5 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
622	17041-10000-06986	380 WORLD WAY 3S515B-3S515C	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	TENANT IMPROVEMENT  IN SHELL SPACE  FOR OFFICE IN LEVEL 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
623	18041-20000-03824	718-726 S MATEO ST	90021	14	124-5A217 303	5166015019	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	10/02/2021 12:00:00 AM	ADDRESS	34.03393	-118.23212	new 1200 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
624	18041-10000-16921	3515 W SUNSET BLVD	90026	13	144A203   174	5429024002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Approved	08/07/2018 12:00:00 AM	ADDRESS	34.08926	-118.27643	Plan check only. PERMIT FEES PAID UNDER APP.# 18041-90000-37023PC FOR TITLE 24 ENERGY ONLY  FOR A  CHANGE OF USE: RETAIL TO RESTAURANT; SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHT. TOTAL AFFECTED AREA 1377 SQ. FTTOTAL CONNECTED LOAD <400AB# 18016-10000-14416	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
625	11041-10000-16974	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	CHANGE TO OUTDOOR LIGHTING, PLAN CHECK FOR T-24 OUTDOOR LIGHTING PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
626	17041-20002-06959	7324 N HYANNIS DR	91307	12	186B093   529	2027015018	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM			PC Approved	05/16/2017 12:00:00 AM	ADDRESS	34.20403	-118.64053	[[5/16/17 CHANGES TO APPROVED SET. REARRANGING MODULES ON STRINGS AND UPGRADING ONE INVERTER TO DELTA 6.6TL]]]PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.56 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
627	15041-10001-16337	8546 N REMICK AVE	91352	6	192B165   118	2634022009	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.22597	-118.4001	EXPEDSITED RSES PER APPLICANT REQUEST.< PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: TRINA SOLAR 225-WATT(22) MICRO INVERTER: ENPHASE M215-60-2LL-S22-IG  >	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
628	15041-10000-42906	4305 W GATEWAY AVE	90029	13	145-5A201 110	5429006019	R2-1XL	Central	Hollywood	Los Feliz		1913.02	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.09431	-118.28361	PC for power only to a commercial building (apartments). Replacing 600 A distribution board with 7 sections and upgrading 28 panels from 40 to 60 amps. No newly connected load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
629	16041-10001-01629	707 W MAC ARTHUR AVE	90731	15	021B197   748	7448005013	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	33.75069	-118.29271	PC only, Permit under Master E#. Increased size of the main breaker from 60A to 100A.  All other remain the same.<<PV1, ROOF MOUNTED SOLAR SYSTEM. (10) MODULES AND (1) INVERTER-3.0KW.  TOTAL SIZE IS 3.0KW.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
630	16041-10001-40751	1120 W WASHINGTON BLVD	90007	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.03867	-118.28211	11/17/2017CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 3 ONLY. CHANGES INCLUDE THE RELOCATION OF THE PULL SECTION, DOWNSIZING TO 800A SERVICE,  AND MODIFICATION OF EXTERIOR LIGHTING. B# 16010-10000-03993.***PC FOR POWER AND ENERGY FOR  NEW 9 STORY PARKING STRUCTURE. PC FOR NEW 1000 A SERVICE. TOTAL AREA IS 170703 SQFT.*NEW KPARKING STRUCTURE (NINE TIERS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
631	10041-20000-12214	13203-13249 N GLADSTONE AVE	91342	7	225B157   672	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			06/25/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.31052	-118.42831	Plan check T-24 Energy outdoor lighting for shopping entrance area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
632	14041-10001-08148	12411 W FIELDING CIR BLOCK 7	90094	11	105B161  1220	4211034054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/17/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	33.97968	-118.40871	revisionto the approved set of plan with adding less than 10 devices and removing some.<<<FA FOR APT. playa vista II - block 7. 5 buildings and 2 FACP. Permit to be split into 5 different applications per building? Plan checker to verify fee arrangment.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
633	14041-10000-08254	2931 N NORTH MAIN ST	90031	1	136-5A223 427	5210017020	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM			PC Info Complete	04/15/2014 12:00:00 AM	ADDRESS	34.06617	-118.21045	This is a two story building,  portin is ti work for swing factory. all others existing.title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
634	17041-10000-17838	12475 W BLUFF CREEK DR	90094	11	102B161  1218	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	05/30/2017 12:00:00 AM		Issued	05/30/2017 12:00:00 AM	ADDRESS	33.97651	-118.41032	PC PER CUSTOMER REQUEST. PC FOR REROUTING OF ELECTRICAL CONDUIT FOR EXISITNG WELL PUMPS. NO BUILDING APPLICATION  PLUMBING PLAN # 17042-10000-11551PLAYA VISTA PROJECT - SOIL REMEDIATION PROJECT. REROUTE PIPING.  LA  APPROVED HDPE PIPING WILL BE INSTALLED. NO PLAN CHECK IS REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
635	14041-20005-35577	706-720 N CAHUENGA BLVD	90038	13	141B185   537	5533032014	C4-1XL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	34.08371	-118.32861	2/16/16 CHANGES TO APPROVED SET OF PLANS. RELOCATION INV1. CHANGES ARE CLOUDED2.11.2015 - Plan check for changes to approved set. Relocate connection of INV2 and INV2A from board MS to panel HP. Add disconnects for both INV1 and INV2. Changes clouded.[[[2/3/16  CHANGES TO APPROVED SET. ADDITION OF INV1A AND INV2A  INVERTERS.]]]11/17/15  changes to approve set. all changes made under delta 8. Scope includes adding site lighting. (((TI TO AN EXISTING COMMERCIAL 2 STORY BUILDING.  ADDING CIRCUITS TO EXISTINF PANELS, NEW LIGHTING AND CONTROLS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 27248.FEES ARE ESTIMATED PLAN CHECKER TO VERIFY.  CORE AND SHELL RENOVATION OF EXISTING STORE W/AXILLARY OFFICE, MANUFACTURING AND STORAGE TO OFFICE USE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
636	16041-20000-43524	11014 W PEORIA ST	91352	7	201B173   358	2538013003	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.24526	-118.37089	pv1install roof mounted pv system sized 16.9kw (ACM) interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
637	14041-20000-22541	17081 W HIAWATHA ST	91344	12	204B133    38	2695019023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	34.25946	-118.50536	PV1.  Install 5.61 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
638	17041-10000-02283	2825-2829 W BELLEVUE AVE	90026	13	139-5A203 173	5402006006	C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Issued	09/20/2017 12:00:00 AM	ADDRESS	34.07689	-118.2754	Plan check for power and energy only in existing building Service upgrade to 600A feed multiple tenants of 2829, 2827, 2825 Bellevue. THIS PERMIT WILL BE FOR CORE AND SHELL WORK ONLY. NO BUILDING SIGN OFF PART OF THIS WORK. THIS IS TO MAKE VANILLA SHELL FOR FUTURE TI. ALL INTERIOR TENANT WORK SHALL BE ON SEPARATE PERMITS FOR BUILDING CARD SIGN OFF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
639	15041-20000-04856	7900 N BALBOA BLVD BLDG N	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Closed	07/08/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	PC FOR T24 ENERGY ONLY. INSTALL OF LIGHTING IN AIRCRAFT HANGERS. PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
640	16041-20001-27009	1905 N ISABEL ST	90065	1	148-5A217 231	5455007030	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM			PC Approved	08/06/2016 12:00:00 AM	ADDRESS	34.10123	-118.23298	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (28) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
641	12041-10000-00165	17037 W DEVONSHIRE ST	91325	12	204B133   128	2695020032	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	34.25769	-118.5035	REMODEL REST ROOMS AND OFFICE -NEW CIRCUITS FOR LUMINAIRES AND OUTLETSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
642	14041-20000-26179	7101 N LUBAO AVE	91306	3	183B113   207	2135010026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.19931	-118.56784	central string inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
643	18041-10000-23150	2300 W BEVERLY BLVD UNIT 101-104	90057	13	136-5A205 272	5154010034	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.06761	-118.27314	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. RETAIL.  FOR UNIT 101 TO UNIT 104.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
644	12041-20000-02059	6901 W PARSONS TR	91042	7	207B201   104	2553013004	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Expired	04/22/2014 12:00:00 AM	ADDRESS	34.2642	-118.28262	Major addition to existing buildingnew 600 A serviceComplete plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
645	19041-10000-31881	4270 S CENTRAL AVE	90011	9	114A209   252	5115030004	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.00606	-118.25629	T-24 PLAN CHECK FOR A TI TO AN EXISING RESTAURANT DINNING AREA & RESTROOM. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 860 SQ,FTB#19019-10000-13147	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
646	15041-20000-34022	4316 W 60TH ST	90043	8	105B181   608	4003009007	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	33.98517	-118.35078	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 6KW AC. (23) MODULES-TRINA SOLAR TSM-250 PD05.05(2) ABB PVI-3.0-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
647	13041-10000-18909	1422 S ABBOT KINNEY BLVD	90291	11	108B145  1450	4238005039	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/17/2013 12:00:00 AM	ADDRESS	33.99029	-118.46524	CHANGE OF USE FROM RETAIL TO SMALL MARKET PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
648	18041-30001-10001	11601 W WILSHIRE BLVD #2100	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Issued	04/03/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	04/03/2018 Plan check for Title 24 only. Project site is an existing suite in a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,336 sq. ft.Note: Building application has been generated under 17016-20000-37787*****Previous Work Description*****Add power to a new tenant space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
649	17041-20001-44710	7517 N CLEON AVE	91352	2	186B173   445	2410001009	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.20713	-118.36827	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array for SFD.3.91kW ungrounded system. (17) EnPhase IQ6 microinverters.(17) 275W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
650	11041-20000-11705	990 W 190TH ST #600	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Apartment			06/07/2011 12:00:00 AM			PC Approved	06/07/2011 12:00:00 AM	ADDRESS	33.85813	-118.29505	T.I. to existing building.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
651	13041-10000-01946	4501 W COLORADO BLVD Bldg # 6	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Public Safety Only			01/24/2013 12:00:00 AM	01/24/2013 12:00:00 AM		Issued	01/24/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	AT THE BAXTER PHARMAUCETICAL FACILITY, EXPANDING THE EXISTING FIRE WARNING SYTEM TO BUILDING 6: AN AUXILIARY FIRE PANEL,  A POWER SUPPLY EXPANDER ON EACH OF THE 5 FLOORS OF BUILDING 6, AND FA DEVICES. THE EXISTING ANNUNCIATOR IN THE GUARD SHACK IS BEING REPLACED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
652	14041-10000-11514	1225 1/2 S LONGWOOD AVE	90019	10	129B181   186	5084024022	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.0526	-118.34059	PV1 2.75KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(11)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
653	14041-20001-26698	22240 W RYAN RIDGE WAY	91367	3	174B101  1455	2146011044	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	34.17127	-118.61164	Expedited plan check per applicant request.  PV1.  Install 19.25 kW DC roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
654	15041-10000-38134	2963 S 4TH AVE	90018	10	120B189   282	5052002007	RD3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	12/19/2015 12:00:00 AM	ADDRESS	34.02783	-118.32134	PV1 roof mounted  installation a single family home. (1) Inverter: 3KW. (9) Solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
655	19041-20001-43384	10420 N DE SOTO AVE	91311	12	204B109    15	2706015017	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM	ADDRESS	34.25957	-118.58833	Revisions to approved plans.  Reconfiguration of rooftop module locations.  New service panel revised to (E) 400A 240/120V 1ph-3w service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
656	18041-10000-25559	1129 W WASHINGTON BLVD	90015	1	126A201   198	5135015031	[Q]C2-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.03905	-118.28192	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
657	14041-20000-00638	8531 N RUBIO AVE	91343	12	192B137   104	2689016004	RA-1	North Valley		North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.22584	-118.49683	New 10.5kw rooftop PV system for an existing single family dwelling.  System is Ungrounded.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
658	18041-10000-24370	3865 S BUDLONG AVE	90037	8	117B197   758	5037010003	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Expired	10/17/2023 12:00:00 AM	ADDRESS	34.01586	-118.29599	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 3.00KWdc / 2.80KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER AND A METER ADAPTER. (10)MODULES-SOLARWORLD  SW-300(10)OPTIMIZERS-ENPHASE S280--60-LL-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
659	12041-20000-12567	17947 W CHATSWORTH ST L2	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM	ADDRESS	34.265	-118.52509	Revised lighting plan check for new restaurant.  Existing permit 11041-10000-27109.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
660	16041-20000-03687	8658 W APPERSON ST	91040	7	204B189   644	2561003015	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.25596	-118.32226	Plan check for PV roof mounted system. System size: 11.4kW with 44 modules  SUNPOWER SPR327NE-WHT-D and 1 inverter SOLAR EDGE SE11400A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
661	11041-20000-26242	2038 E BAY ST	90021	14	123A217   194	5166011014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	ADDRESS	34.0313	-118.23081	energy plan check office/warehouse	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
662	18041-10000-45890	12921 W MAGNOLIA BLVD	91423	4	171B161   451	2345017031	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.16503	-118.41465	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
663	08041-10001-27387	6000 W JEFFERSON BLVD	90016	10	117B169     5	4204008901	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		7025.02	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM			PC Info Complete	04/28/2010 12:00:00 AM	ADDRESS	34.02089	-118.37884	Supplemental for relocate switchboard from electrical room to outside, rearrange connect 25KVA transformer, and add 3 motors.  Plan check for power only.  Approved plans submitted for reference only. Nema 3R used for outside equipment,New fault current shows 22K, calculation shows fully rated system.*******Original P/C has expired (06041-10000-02621), plans have been resubmitted for plan review.  SEWER GAS TREATMENT FACILTY- CLASS I, DIV 2 LOCATIONS. Fire alarm has been submitted on a separate application under 06041-10000-02432.******	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
664	17041-10001-19815	10930 W CHALON ROAD	90077	5	141B149    91	4369021009	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM			Reviewed by Supervisor	09/20/2017 12:00:00 AM	ADDRESS	34.08454	-118.45731	PC for four Powerwall 2's installed in SFDwith new 125A load center. No existing PV installed,powerwalls are powered by utility. Total system sizeis 54kWh. Note that expresspermit was pulled under 17041-90000-19815.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
665	11041-10000-12606	616 N ALAMEDA ST	90744	15	030B213   219	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2947.00	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM	04/12/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	33.77832	-118.24681	New 1600Amp service & Distribution board for the port of LA.  EPC is for Power.   No New Load added.   <<<EPC will be required when the FUTURE 500 Amp Load is added.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
666	15041-10001-14013	7820 S KENYON AVE	90045	11	099B161   185	4112022008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM			PC Approved	05/18/2015 12:00:00 AM	ADDRESS	33.96946	-118.41236	expedited rses plan check per applicant request.<<PV1, Install 2.75 kW DC roof-mounted solar array, interconnect with service panel. new utility lockback AC disconnect. (11) panels 11 microinverter.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
667	13041-10000-33078	7957 N KENTLAND AVE	91304	12	189B097   455	2013010040	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Verifications in Progress	04/11/2014 12:00:00 AM	ADDRESS	34.21532	-118.61784	PV1.  Install 4.5 kW roof-mounted PV system, interconnect with main service panel.  16 modules: Trina Solar TSM-250PA05.18.  Transformerless inverter: SolarEdge SE3800A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
668	16041-20001-13689	350 S HILL ST	90013	14	130-5A211 149	5149015024	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.05047	-118.24998	Revisions to approved plans to reflect architectural changes to number of stories/use of individual stories.  Changes clouded.  INSTALLATION OF A NEW FIREALARM SYSTEM FOR BRAND NEW MIXED USE HIGH RISE BUILDING.  36 PANELS AND 2584 DEVICES AND 733 SMOKE DETECTORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
669	19041-10000-01864	12923 W FOOTHILL BLVD	91342	7	219B161   275	2514003045	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.29443	-118.41591	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
670	19041-20000-24618	9707 N AMIGO AVE pv1	91324	12	201B125   304	2763033037	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	PIN	34.24654122	-118.53809073	pv1install roofmounted pv system 6.3KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
671	12041-20000-20237	12750 W RAYMER ST	91605	2	186B161   550	2324004001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03, 1233.04	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.20367	-118.40986	Ti Change to lighting receptacles for existing low rise building load is less than 200 amps plan check only for energy. Permitt fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
672	16041-10000-29895	8969 N BRADLEY AVE	91352	6	195B169   180	2408037017	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.23194	-118.37857	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 56340 SQ FT.(outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
673	11041-10000-15317	1201 E WASHINGTON BLVD	90021	9	121-5A211 394	5131003002	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	34.02503	-118.25126	Install a new Fire Life Safety System in the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
674	14041-10000-32540	10663 W KINNARD AVE	90024	5	132B153   770	4326024022	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Apartment			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.0558	-118.43356	new fire alarm for a five story six units condos. one panel and 155 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
675	17041-10000-34995	12506 W OXNARD ST	91606	2	177B165   761	2341001009	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Issued	11/03/2017 12:00:00 AM	ADDRESS	34.17922	-118.40557	Tenant improvement in retail storPlan check for title 24 onlyNote: Additional permit fees have been paid under 17041-20000-24428.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
676	14041-20000-28918	7125 N YOLANDA AVE	91335	3	183B121   248	2126004007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.20004	-118.54055	PV1SDFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTERS. TOTAL OF 27 MODULES. USING STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
677	19041-20000-32637	226 N LAKE ST #1 - #36	90026	13	136-5A205 169	5157020023	R4-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	03/02/2021 12:00:00 AM	ADDRESS	34.06878	-118.2701	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW FIVE STORY 36 UNIT APARTMENT BUILDING. SCOPE OF WORK CONSISTS OF (1) FACP AND (84) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
678	10041-20000-18348	245 S MAIN ST	90291	11	111B141   545	4286017***	(Q)C4-2D	West Los Angeles	Venice	Venice		2734.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	33.99681	-118.47872	energy plan check subway sandwish shop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
679	05041-10008-23847	100 W 1ST ST	90012	15	018B201   695	7449017007	MR2-1VL	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM	03/15/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	34.0523	-118.24406	NE W LA POLICE HEADQUARTERSVARIANCE IS FILED TO SEPARATE THE FA PLANSNOTE: THIS IS A BOND PROJECT WHICH IS TO BE ASSIGNED WITHIN THREE DAYS4-10-09 new area for FBI to separate the area , block off windows and addition of 4 panels and 55 ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
680	16041-20000-31898	12346 N VILLAR WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29503	-118.45489	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
681	13041-20000-07379	8009 W WENTWORTH ST	91040	2	208-5A193 112	2551039040	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	34.2671	-118.30744	Install new UNGROUNDED PV rooftop system on an existing single family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
682	19041-10000-44477	1212 E PACIFIC COAST HWY	90744	15	036B209   685	7425021050	[Q]C1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	33.79074	-118.24844	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
683	15041-20000-39893	15900 W MULHOLLAND DR BUILD. 3&4	90049	5	156B141     4	4490001023	RE40-1-H	South Valley	Brentwood - Pacific Palisades	Bel Air - Beverly Crest	YES	1415.00	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.12665	-118.47908	Lighting and power TI of (2) upper level classroom at Milken Community shcool. The scope of work covers ADI and GFI buildings. Relocating 225A Panel Total area: 11,509sq.ft. Full PC.Build Application under B15VN16197 and B15VN16197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
684	11041-20000-02668	1905 N NORTH MAIN ST	90031	1	135A221    13	5410018032	M2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.06622	-118.21925	Plan check for new 15.510KW roof mounted photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
685	18041-10000-26383	3131 S HOOVER ST #1930	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM			PC Info Complete	08/03/2018 12:00:00 AM	ADDRESS	34.02605	-118.28472	PLANCHECK FOR POWER AND ENERGY.  FIRST TIME TENANT FOR  PORTION OF EXISTING MIXED USE CORE AND SHELL BUILDING TO BEAUTY SALON. 1202 SQFT.BUILDING PERMIT # 18016-10000-19404	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
686	13041-10000-17839	23015 W RUNNYMEDE ST	91307	12	186B097   624	2021006003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.2051	-118.62839	PV1.  Install 5.75 kW DC roof-mounted PV array, interconnect into main service panel.  {23 modules: Trina Solar TSM-250PA05.08} {Transformerless inveter: Power One Aurora PVI-4.2 OUTD-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
687	17041-10000-31510	600 W 9TH ST 135	90015	14	127-5A207  12	5138001***	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM			PC Info Complete	09/27/2017 12:00:00 AM	ADDRESS	34.04534	-118.26103	PC FOR RETAIL TI  IN A HIGH RISE(CHANGE OF USE SUITE 135 FROM OFFICE TO RETAIL PET STORE) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS RECEPTACLES AND LIGHTS.  TOTAL AFFECTED AREA 1653 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
688	14041-20002-09925	17500 W BURBANK BLVD	91316	5	174B129   855	2254037019	RA-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.17213	-118.51506	(($0 PLAN CHECK FEE DUE TO SENATE BILL 1222 FROM 2012))CHANGES TO APPROVED SET OF PLANS. DOWNSIZE AN INVERTER. CHANGE IN DC MODULE. TOTAL SYSTEM SIZE IS NOW 76.6KW AC / 93.48 KW DC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
689	17041-10001-17856	2205 S 5TH AVE	90018	10	123B189    95	5060024008	RD2-1-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2188.00	Electrical	Electrical	Apartment			06/20/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	ADDRESS	34.03687	-118.32261	PC FOR PV SYSTEM ON APARTMENT BUILDING. 3 UNITS. PERMIT ALREADY ISSUED UNDER MASTER AND UPDATED TO REFLECT COMMERCIAL PROPERTY. THIS APPLICATION IS PC ONLY PV ON COMMERCIAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
690	10041-10000-16319	7624 W MELROSE AVE	90036	5	141B177   643	5526015027	C4-1XL-O	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	PIN	34.08343585	-118.35617379	FULL REMODEL OF (E) STARBUCKS.  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
691	15041-10000-19539	1026 S BROADWAY BLDG A	90015	14	126A209    92	5139014017	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			06/22/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	05/30/2020 12:00:00 AM	ADDRESS	34.04029	-118.25788	NEW FIRE ALARM SYSTEM TO A HIGH RISE RESIDENTIAL 7 FLOOR BUILDING. TOTAL FIRE ALARM DEVICES 1189, 1 FIRE ALARM CONTROL. note: power supply need to be verify in fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
692	12041-20000-03780	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM			PC Approved	02/29/2012 12:00:00 AM	ADDRESS	34.20696	-118.3417	New film school buildingEnergy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
693	14041-10000-00129	1200 S SAN PEDRO ST STE #102	90021	14	124-5A211 326	5132012051	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	PIN	34.0334209	-118.25310746	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 320 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
694	14041-20001-30665	12180 W MILLENNIUM 1st, 2nd-floor	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	"Change to approve set of plan. Replace 6"" recessed luminaries to 4"" -23 watt. ((((((T.I. to existing building on the 1st and 2nd floors.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy.)))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
695	13041-20000-26268	5249 N LANKERSHIM BLVD	91601	2	171B173   417	2350017033	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.1662	-118.37562	"Change of use from retail to restaurant.  Load is less than 200 amps and occupancy load is 40.  PLAN CHECK ONLY for Energy, with Emergency lighting.  ""COMPLY WITH DEPARTMENT ORDER effective date07/13/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"" permit al;ready issued under application #13041-20000-13243"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
696	12041-10000-28789	2519 S AIKEN AVE	90064	5	126B161    94	4318012004	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.04196	-118.41778	PV1:  8.64 KW solar system for a single family residence.  Applicant is using the standard plan.  Plan check is done over the counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
697	15041-10000-21036	600 WORLD WAY TERMINAL 6-LV.3 #622	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM			PC Info Complete	07/02/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	TI TO AN EXISITNG COMMERCIAL SPACE.  ADDING NEW LIGHTING TO MILLWORK AND CABINETS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
698	12041-10000-04907	14113 W ROSCOE BLVD	91402	6	192B153   753	2638030026	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Public Safety Only			03/05/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.22183	-118.44069	New fire alarm system for a preschool.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
699	19041-30000-11167	2451 N ARBUTUS DR	90049	11	141B133   330	4492006015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM			PC Approved	11/03/2022 12:00:00 AM	ADDRESS	34.07919	-118.50361	Plan check only for power only plan check. Project site is a 3-story single family dwelling. Work includes a 800 amp service with panels, power, and lighting.Note: Building permit has been issued under combo 16010-30000-05298, electrical permit covered under the combo permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
700	19041-10000-51280	8108 S VERMONT AVE	90044	8	099B197  1065	6032005016	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	07/09/2020 12:00:00 AM		Issued	07/09/2020 12:00:00 AM	ADDRESS	33.96518	-118.29134	permit Zero fee due to ABand SB 1212.  PV2, NEW ROOFTOP AND CANOPY MOUNTED PV SYSTEM, SYSTEM SIZE IS 50KWac/46.4KWdc. SCOPE OF WORK IS 116 MODULES (400w LG) WITH RAPID SHUT DOWN DEVICES (TIGO TS4-R-F), LEADING TO A CENTRAL INVERTER (SMA TRIPOWER STP 50-US-41), A NEW 53 KVA TRANSFORMER, TERMINATING IN SOLAR PV BREAKER, NOTE THERE IS A NEW 600A SERVICE, WHICH IS IN PLAN CHECK UNDER 19041-10000-47092.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
701	16041-10001-02779	300 S GRAND AVE # 2750	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check Title 24 only for Existing building. Total area: 3,348 sq ft. {{{{{SMALL T.I. IN (E) BUILDING.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
702	16041-10000-39876	248 N LARCHMONT BLVD	90004	4	138B189   455	5515025001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.07598	-118.32343	PC FOR ENERGY ONLY. T.I. CHANGE OF USE FROM RETAIL SHOP TO CAFE. TOTAL AREA 736 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
703	18041-20000-48726	20500 W NORDHOFF ST	91311	3	195B109    84	2780001049	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.23165	-118.58008	new fire alarm system 30 devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
704	16041-10000-38690	1508 N HAZELWOOD AVE	90041	14	156A221    73	5474013026	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Issued	11/01/2016 12:00:00 AM	ADDRESS	34.12341	-118.21472	PV, INSATALLATION OF NEW 5.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL PROPERTY. (16)MODULES:  AXITEC AXIPOWER AC 320P/156(1) INVERTER: FRONIUS PRIMO 5.0-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
705	15041-10001-35815	8825 S SEPULVEDA BLVD	90045	11	096B165   990	4122035027	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM	ADDRESS	33.9565	-118.39648	03/02/16Changes to an approved set of plans. Relocating starbucks kiosk on site plan due to an extra checkstand. Also relocating one exit sign. ((((PC FOR T24 FOR STARBUKS KIOSK  INSIDE RALPH STORE. TOTAL AREA 280 SQ. FT FOR STARBUCKS LIGHTING.  AND 1080 SQ. FT. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
706	18041-20000-03153	4838 N GLORIA AVE	91436	5	168B141   368	2261013008	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.15805	-118.47902	pv1install roof mounted pv system sized 11.2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
707	17041-10000-39904	1647 N MANDEVILLE CANYON ROAD	90049	11	135B137   621	4426001016	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.06264	-118.49378	Adding three energy storage systems to an existing PV system and a new load center.System consist of 3 powerwalls 13.5KWh each.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
708	18041-20000-40518	11869 S TEALE ST	90230	11	105B165   394	4220006065	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	33.98458	-118.4024	Plan check for Title 24 only. Project site is the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 13,726 sq. ft.Note: Building application has been generated under 18016-10000-26470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
709	15041-10002-18980	3224 N GLENDALE BLVD	90039	13	153B209   216	5436025001	[Q]C4-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.11798	-118.26045	12/08/2015Changes to an approved set of plans. Note changes on delta 1, changes include the change of fixtures. ((TI TO AN EXISTING RESTAURANT.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2230.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
710	10041-10000-12586	4827 E HUNTINGTON DR NORTH	90032	14	142-5A233  61	5213002011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	11/05/2010 12:00:00 AM		Permit Closed	12/28/2012 12:00:00 AM	ADDRESS	34.08611	-118.17939	ON SITE ARE ONE EXISTING BUILDINGS SUBDIVIDED INTO 4 TENANT SPACES; SECOND & THIRD BUILDINGS WERE CONSTRUCTED TO SERVE AS ONE TENANT WAREHOUSE AND THREE TENANT SPACES. THESE BUILDINS DO NOT SHARE A COMMON ROOF. PLAN CHK WILL BE FOR THESE BUILDINGS BUT PERMIT WILL BE OBTAINED FOR EACH BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
711	19041-20000-11065	18325 W BLYTHE ST	91335	3	189B125  1006	2102015086	(T)(Q)R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.21487	-118.53268	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SINGLE FAMILY DWELLING. SYSTEMS SIZE IS 6.1KW DC/5KW AC. SCOPE OF WORK INCLUDES 20 CANADIAN SOLAR 305W PV MODULES WITH SOLAR EDGE P320 OPTIMIZERS, AND AN SE5000H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
712	16041-20000-21311	6022 N VARIEL AVE	91367	3	177B105    62	2149005021	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.18017	-118.59257	New 74 device fire alarm system with (N) FACP in single story B/A3 occupancy building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
713	16041-20000-13679	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.2215	-118.42999	Plan check for a PV2 carport PV system. System size is 348 kWac and consists of (11) inverters, (1360) modules, and (1) load center.Note: Building application has been created under 16014-20000-01761	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
714	16041-10001-45044	1925 W OLYMPIC BLVD	90006	1	130-5A203 221	5136008025	C4-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.05119	-118.27827	PC FOR CHANGES TO APPROVED SET UNDER DELTA 2 TO REFLECT FIELD WORK. SCOPE INCLUDES NEW SUBPANEL  WITH NEW CIRCUITS.  SOME LOAD REVISION TO PANELS SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
715	11041-10000-04941	468 S LA BREA AVE	90036	4	135B181   575	5507009014	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.06511	-118.34381	New 800 amp service. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
716	16041-20000-29190	23825 W VANOWEN ST	91307	12	183B089   761	2034032065	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.19362	-118.64544	install solar array on SFD. Interconnect 125A MSP. 3kW ungrounded system. (16) 255W  PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
717	13041-10001-13171	6330 W SAN VICENTE BLVD 310	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	ADDRESS	34.06116	-118.36804	MODIFICATION TO APPROVED SET OF PLANS. PANEL SCHEDULES, SINGLE LINE AND POWER PLAN UPDATED TO REFLECT NEW LOCATION OF X RAY EQUIPMENT. SUITE NUMBER 310********************************************************************************PLAN CHECK FOR MEDICAL FACILTIY. WORK IN PATIENT CARE AREAS. POWER AND ENERGY. CHANGE OF USE FROM OFFICE TO ORTHEPEDIC CENTER. COMMUNICATION EQUIPMENT NOT IN SCOPE OF PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
718	19041-20001-34011	10925 W BLUFFSIDE DR	91604	2	162B173   304	2366021008	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			PC Approved	12/03/2019 12:00:00 AM	ADDRESS	34.14115	-118.36774	Expedite per appliant request Plan check for PV roof mounted PV system, PV system size: 69.12KW DC, 62.7KW AC with 192 PV Modules and 7 inverters(9) connected to 1200A 120/208 Volts 3 phase	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
719	18041-20001-29902	15914 W VINTAGE ST	91343	12	204B141  1068	2669016017	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.25184	-118.47903	expeditepv1install roof mounted pv system sized 10.2KW AC interconnected with msp.(32) panasonic 330W modules(32) enphase energy IQ7X microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
720	13041-10000-24140	1930 E 15TH ST	90021	14	120A215   173	5167019023	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Closed	09/09/2015 12:00:00 AM	ADDRESS	34.02261	-118.23619	"PLAN CHECK FOR NEW 1200AMP SWITCHBOARD REPLACING AND EXISTING 1000 A SWITCHBOARD, 1 PANEL AND 1 TRANSFORMER. PANEL ""A"" LOADS ARE EXISTING. NO UNDERGROUND WORK OR PENETRATIONS OF METHANE MEMBRANE IS IN SCOPE OF WORK. METHANE BUFFER ZONE. PREVIOUSLY APPROVED 1000A SWITCHBOARD UNDER APPLICATION NUMBER 09041-10000-21663.**************************************************************T.I. for warehouse building.  Renew vandalized switchboard to feed an existing panels.  Plan check for power only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
721	17041-10001-02310	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	ADDRESS	34.13829	-118.34154	CHANGES TO AN APPROVED SET OF PLANDS.PLANCHECK ONLY.  DELTA 7 CHANGES CLOUDED. CHANGES TO NORTH CLUBHOUSE POWER AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
722	10041-10000-24556	814 E TRACTION AVE 2nd & 3rd-floors	90013	9	127-5A215  80	5163013003	(T)(Q)CM-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.04489	-118.23562	Ti in an existing office. EPC is for T24 and Emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
723	15041-10000-31733	1150 S OLIVE ST 13TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI TO AN EXISTING COMMERCIAL BUILDING 13TH FLOOR.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 1810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
724	16041-10000-45243	8654 N MASON AVE	91306	3	195B109   357	2781007024	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	05/16/2017 12:00:00 AM	ADDRESS	34.22794	-118.57961	pv, install new 5.4 kw dc roof-mounted solar array on a single family house.(18) modules: HANWHA q-cell q peak-g4.1, 300 w()1 inverter: solar edge SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
725	16041-10000-24265	1315 E ADAMS BLVD	90011	9	117A211    16	5118009017	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Expired	08/23/2018 12:00:00 AM	ADDRESS	34.01644	-118.24952	Rooftop solar instalation on a SFD, 1.72 kW AC.   (8) HiS-M250MG,   (8) Enphase M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
726	16041-10001-04213	2829 E WHITTIER BLVD	90023	14	123A223   144	5185037012	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.03159	-118.2091	PERMIT ISSUED UNDER MASTER, THIS APPLICATION IS PLAN CHECK ONLY. NEW LIGHTING. T24 ENERGY ONLY. BUILDING PERMIT FOR ADDITION TO RETAIL. GREEN COMPLIANCE MANDATORY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
727	17041-30000-09744	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	Title 24 plan check.  T.I. to 9th floor of existing commercial office highrise building.  One new 100 A subpanel.  New lighting and receptacles.  Total area = 7,605 sq. ft.Building permit #17016-10000-02744	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
728	19041-20000-49568	14525 W KILLION ST #1-3	91411	4	174B149   937	2249001008	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM			Permit Closed	01/22/2021 12:00:00 AM	ADDRESS	34.17135	-118.4497	FULL PLAN CHECK FOR NEW 600A SERVICE, (6) PANELS, AND EQUIPMENTS.THIS PERMIT IS UNDER BUILDING PERMIT 17010-20000-02117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
729	14041-20000-29588	11726 W HUSTON ST	91607	2	168B169   221	2355017026	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.15936	-118.38865	PV1Using standard plan.Install a roof-mounted solar array on SFD.System size: 7.6kW (3.8+3.8). Ungrounded system.39 255W pv modules across 2 strings.Using 300W power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
730	11041-10000-22040	5101 W MELROSE AVE	90038	13	141B193   538	5535015014	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			10/14/2011 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Expired	04/29/2014 12:00:00 AM	ADDRESS	34.08364	-118.3116	Service upgrade to 800 Amps for two existing Apt Buildings (5101 & 5115 Melrose).;Overhead 800aA drop to supply existing 20 units apt building at 5101 Melrose and to supply existing 22 units apt building at 5115 MELROSE; THERE IS NO  WORK TO BE DONE IN ANY OF THE DWELLING UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
731	15041-10000-18339	1406 S BONNIE BRAE ST	90006	1	127-5A201 160	5135006002	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.0441	-118.28101	PV1 INSTALL 5.886 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR327NE(1)INVERTER: POWER ONE PVI -5000-OUTD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
732	19041-20000-37127	11700 N RICASOLI WAY	91326	12	216B109    99	2701077036	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.28491	-118.58414	Plan check for PV roof mounted system, PV system size: 13.53KW DC, 12.46KW AC  with 41 PV Modules and 41 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
733	16041-10000-44961	5500 N LANKERSHIM BLVD	91601	2	174B173  1259	2350008058	C2-2D	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.17013	-118.37756	Full plan check for a new vehicle warehouse, 3 tiers. New equipment rated at 600 amps. New lighting and power. Total area: 269,032.Building app. #16010-30000-05952.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
734	17041-20000-19306	6111 N TOPANGA CANYON BLVD #4	91367	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.18157	-118.60615	Plan check for Power only. Replacing existing service with new Temporary switchboard service that is being installed for car dealership use.  New Switchboard is rated at 600 amps 277/480 V 3phase 4wire. Existing load is being rewired/relocated, and also adding new load (construction trailers).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
735	19041-10000-19735	3250 W SAN FERNANDO ROAD	90065	13	153B209   283	5458002017	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.1172	-118.24859	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
736	17041-10001-22830	2181 W WARMOUTH ST	90732	15	009B189   501	7563037056	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM			PC Approved	01/14/2019 12:00:00 AM	ADDRESS	33.71969	-118.32448	SUPPLEMENTAL PLANS CHECK FOR ( DELTA 1 ) CHANGES TO APPROVED SET - CHANGES INCLUDE RELOCATING TRE 200A AC DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
737	16041-10000-35999	10250 W SANTA MONICA BLVD # 1625	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Compartes Store"" Ste. 1625.  Install new Xrfmr, and  panels < 200A, total area 407 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
738	15041-20000-28470	1425 N VIA ANITA	90272	11	132B121   162	4420038009	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Expired	10/04/2017 12:00:00 AM	ADDRESS	34.05838	-118.53831	Plan check for PV roof mounted system. System size: 10.0kW with 36 modules and 1 inverter(10.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
739	16041-20000-17818	1563 W SUNSET BLVD	90026	13	139-5A209 169	5419028006	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.07679	-118.25693	TI/CHANGE OF USE FROM RETAIL TO BARBER SHOP FOR AN EXISTING SINGLE STORY COMMERCIAL BUILDING INCLUDING SERVICE UPGRADE 600 AMPS.  PLAN CHECK FOR POWER AND ENERGY.Note: Building permit has been issued under 16016-10000-04822	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
740	13041-20000-03603	2029 S CENTURY PARK EAST # 1350	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			Corrections Issued	02/12/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. FOR OFFICE ON 13TH FLOOR.  NON-BEARING PARTITIONS, MILLWORK, SUSPENDED CEILING AND ENTRY VESTIBULES.  7,342 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
741	14041-20000-17481	6920-6930 N VAN NUYS BLVD	91405	6	183B149   499	2217009801	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Reviewed by Supervisor	08/08/2014 12:00:00 AM	ADDRESS	34.19604	-118.44846	ADDITION TO EXISTING TELECOMMUNICATION SPACE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
742	14041-10000-02680	4260 E PALMERO DR	90065	1	153A219   100	5475004013	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.11467	-118.22269	PV1, Install 2.75 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3000A-US-ZB-U. (12) Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
743	12041-10000-28967	6263 W DE LONGPRE AVE	90028	13	147A189   139	5546023031	R4-2D	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.09628	-118.32592	in a parking lot , installing 4ea post-supported luminairesplan check is for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
744	19041-20003-11122	23150 W AVENUE SAN LUIS pv3	91364	3	171B093   784	2074021035	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Apartment			10/18/2019 12:00:00 AM			PC Approved	10/18/2019 12:00:00 AM	ADDRESS	34.16135	-118.63106	10/18/19CHANGES TO APPROVED SET DELTA 2 ONLY CHANGES TO SHORT CIRCUIT CALCS.<<<permit fees $0.00 by state senate bill no. 1222Plan check for PV roof mounted system, system size: 73.3kW AC and 83.22KW DC with 228 PV Modules and 2 inverters(20KW) and (1) inverter (33.3KW)>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
745	12041-10002-19473	3515 W WILSHIRE BLVD Floors1 &2	90010	10	132B193    16	5502032017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.0619	-118.30094	SUPPLEMENTAL PLAN CHECK TO APPROVED SET. ALL CHANGES ARE CLOUDED. CHANGES TO THE SECOND FLOOR BAR LOUNGE. DELTA CHANGES DEPENDANT ON PAGE. ALL CLOUDED CHANGES ARE NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
746	12041-10003-30784	12751 W MILLENNIUM B	90094	11	102B161  1235	4211033050	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/24/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Expired	10/24/2017 12:00:00 AM	ADDRESS	33.9761	-118.41651	Change to approved set, all changes are under delta-38 and the clouded area only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
747	18041-10000-33462	1800 S AVENUE OF THE STARS Suite #105	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.06095	-118.41786	TI IN AN EXISTING RESTUARANT IN SUITE #105 ON THE FIRST FLOOR.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
748	15041-20000-29057	6238 N ENFIELD AVE	91335	5	177B129   119	2123034004	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	PIN	34.18314188	-118.52376774	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel.(25) Kyocera KU 265 Moudles(1) PVI-5000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
749	15041-10000-05667												Electrical	Electrical	Apartment			02/05/2015 12:00:00 AM			PC Approved	02/25/2015 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
750	15041-10000-42525	300 S SANTA FE AVE SUITE M	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	NEW BOOK STORE. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
751	14041-10000-34114	15519 W SUPERIOR ST	91343	7	201B145   458	2656030022	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Expired	01/03/2017 12:00:00 AM	ADDRESS	34.24654	-118.47062	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
752	18041-10000-37976	8645 S SEPULVEDA BLVD	90045	11	096B165   693	4122001012	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Issued	10/04/2018 12:00:00 AM	ADDRESS	33.95857	-118.39645	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES RETROFIT REPLACEMENT TO LED LIGHTING. EXISTING WIRING AND CIRCUITS. TOTAL SQ. FT. 8636	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
753	15041-20001-06867	891 S BRONSON AVE	90005	4	132B189   840	5092002019	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2015 12:00:00 AM			PC Approved	03/24/2015 12:00:00 AM	ADDRESS	34.05634	-118.3209	Expedite per applicant request((((Plan check for PV roof monted 8kW system with (32) 250w microinverters)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
754	10041-20000-19618	15524 W LANARK ST	91406	6	189B145    64	2654040004	M2-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Commercial			10/01/2010 12:00:00 AM			PC Approved	11/02/2010 12:00:00 AM	ADDRESS	34.21839	-118.47093	T.I. in existing space.  Install new panels and lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
755	13041-10001-03792	11642 N LUANDA ST	91342	7	213B169   101	2531011029	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.2839	-118.38466	Changes to approved set: Modules REC 245-PE BLK changed to REC 250-PE BLKOriginal Work Description: PV1 FOR SINGLE STORY HOUSE.  3.672 KW.  17 MODULES {MODULES: REC245PE} {MICROINVERTERS: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
756	16041-20000-06242	865 S FIGUEROA ST flrs 26&28	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLANCHECK FOR POWER AND ENERGY.  26TH FLR (7,198 SF) & 28TH FLOOR (19,271 SF, FULL FLOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
757	14041-10001-13909	13604 W SHERMAN WAY	91405	2	183B157    75	2328008008	(T)(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			05/23/2014 12:00:00 AM			Verifications in Progress	04/14/2015 12:00:00 AM	ADDRESS	34.20102	-118.4293	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY ON A 64 UNIT AFFORDABLE APARTMENT WITH 100 MODULES. 10 STRINGS. THE DRAWING FOR SOLAR PLAN COMES WITH ORIGINAL PLAN  WITH APPLICATION #14041-10000-13895.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
758	17041-20000-21274	16124 COLUMBUS LN	91343	12	192B141   234	2673019073	(T)(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM				pv1install rof mounted pv susyem sized 3.8kw intercomnnectd with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
759	13041-10000-03792	11642 N LUANDA ST	91342	7	213B169   101	2531011029	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	34.2839	-118.38466	PV1 FOR SINGLE STORY HOUSE.  3.672 KW.  17 MODULES {MODULES: REC245PE} {MICROINVERTERS: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
760	14041-10000-14951	5301 N WINNETKA AVE	91364	3	171B113   166	2166006001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.16609	-118.57071	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS NON STANDARD PLAN. SYSTEM SIZE: 9 KW DC.(36) ET SOLAR MODULES(2) POWER ONE PVI 3.8 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
761	16041-20000-43729	10902 N CARTWRIGHT DR	91311	12	210B113   259	2708030022	(T)(Q)RA-1-H, (T)(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.26876	-118.56617	PV1.  Install 8.04 kW DC roof mounted grid tied PV system.  AC module standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
762	19041-10000-15424	527 S CERES AVE	90013	14	126A215    52	5147017022	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.04091	-118.24059	T-24 ENERGY ONLY PLAN CHECK FOR A COMMERCIAL WAREHOUSE GENERAL LIGHTING. SCOPE INCLUDES 2 NEW 100A PANELS, NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 9288 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
763	15041-10000-25785	8640 S VERMONT AVE	90044	8	097-5A199 334	6038010018	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	33.95922	-118.29137	FULL PC FOR A NEW RETAIL BLDG. 4 NEW TENANTS (1) STORY BLDG, INDOOR AND OUTDOOR LIGHTING  TOTAL SQ FT = 8175.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
764	12041-20000-02369	8550 N BALBOA BLVD coor 195	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.22649	-118.5024	energy plan check cooridoor 195	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
765	16041-10000-36330	614 S ST ANDREWS PL	90005	10	135B193   930	5503032008	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM			Verifications in Progress	05/12/2017 12:00:00 AM	ADDRESS	34.06286	-118.3114	Full plan check. Power and energy. Fire damage repair of existing Appartment building 59 units 6 story. Plan check should be in compliance with 2008 compliance code. Total area: 9,781 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
766	17041-20000-11832	17075 W DEVONSHIRE ST	91325	12	204B133   139	2695020031	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.2577	-118.50483	PV2.  Install roof-mounted PV system sized 57.6kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
767	17041-10000-43806	19827 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.85047	-118.28661	REPLACE HID OUTDOOR FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
768	18041-20000-44376	1902 S CAMDEN AVE	90025	5	126B153    22	4323014017	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.0454	-118.43963	Plan check for PV roof mounted system plus energy storage system. PV system size: 6.12KW DC, 7.6kW AC and 9.8kWh LG CHEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
769	17041-10000-10322	14920 W ASTORIA ST	91342	7	219B149   632	2611007053	(T)(Q)C2-1-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Apartment			03/30/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.29576	-118.45588	Plan check for new Fire alarm system 140 unit 5 story building. Fire alarm devices: 483 and 8 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
770	16041-10000-45780	5203 N LANKERSHIM BLVD	91601	2	171B173   590	2350017058	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			Reviewed by Supervisor	01/09/2017 12:00:00 AM	ADDRESS	34.16507	-118.37498	FULL PC FOR POWER AND ENERGY FOR A NEW BUILD RESTAURANT. SCOPE INCLUDES NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. FIRST TIME TENANT. TOTAL AFFECTED AREA IS 315 SQ. FT. B#16010-10000-05338	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
771	11041-10000-03567	525 S FLOWER ST	90071	9	130-5A209 146	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.05109	-118.25696	TENANT IMPROVEMENT  ON THE B-LEVEL, 1ST THRU 3RD FLOORS OF AN OFFICE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
772	17041-10000-39216	19726 W SHERMAN WAY	91306	3	183B117    69	2135016021	C4-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.20085	-118.56329	PC for T24 only for repalcement of metal halide fixtures withnew led. Total area is 3700sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
773	19041-30000-05344	12100 W WILSHIRE BLVD Ste 650	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.0438	-118.46755	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,388 sq. ft.Note: Building permit has been issued under 19016-40000-01218	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
774	14041-10000-28287	8631 W 3RD ST Ste 510	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	T.I. to medical office.  New lighting and recepticles.  Total area = 5685 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
775	17041-10000-24223	707 W WILSHIRE BLVD STE 4900	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.04893	-118.2572	PC for T24 for office TI. Total area is 1263 sqft. PC for new lights. Building PC 17016-10000-17463	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
776	17041-10000-05525	9901 N DRONFIELD AVE	91352	7	201B173   181	2538024901	OS-1XL-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.24936	-118.37489	PLAN CHECK FOR ENERGY ONLY. TI (E) STONEHURST REC CENTER. TOTAL AREA: 250 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
777	17041-20000-06959	7324 N HYANNIS DR	91307	12	186B093   529	2027015018	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.20403	-118.64053	"""0$ permit fees due to senate bill 1222 ""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.56 KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
778	19041-20000-24835	13754 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM			PC Approved	06/27/2019 12:00:00 AM	ADDRESS	34.30932	-118.43311	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
779	13041-10000-00572	7122 W BEVERLY BLVD	90036	5	138B181   432	5513002032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/30/2013 12:00:00 AM	ADDRESS	34.07599	-118.34481	T.I.  Exisiting Starbucks.  Modification to the interior lighting.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
780	17041-20000-31071	715 S PARK VIEW ST	90057	1	132A201    54	5141015031	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			Reviewed by Supervisor	10/03/2017 12:00:00 AM	ADDRESS	34.05732	-118.28034	Plan check for power and energy.  (N) MIXED USE RETAIL & 6 STORY 60 UNITS APT/ BASEMENT GARAGE -  5 STORIES OF APT W/ ROOF DECK OVER 2 LEVELS OF BASEMENT PKG W/ RETAIL.1,600A 120/208V 3ph 4w service. 5 typical units. T24 area - 32,500sqft (??? verify) - T24 documents not provided at time of submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
781	14041-20000-13139	13656 N FENTON AVE	91342	7	228B153   381	2503009007	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.32035	-118.43392	Roof mounted PV system.  System size 14.5KW.Note: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
782	13041-20000-31214	12727 W SHERMAN WAY	91605	2	183B161    11	2324004004	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.20137	-118.41091	Change of use from retail to laundry mat.  Full Plan Check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
783	10041-10000-12040	800 E 12TH ST 115	90021	9	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	07/08/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	new track lighting system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
784	10041-10000-20603	11167 W PENROSE ST	91352	6	195B173   452	2408023002	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	02/10/2012 12:00:00 AM		Issued	02/10/2012 12:00:00 AM	ADDRESS	34.22718	-118.37456	Service upgrade for existing building reconnect one exiting panel and connect one new panel.  No change to building lighting.  Power only plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
785	19041-20000-37001	2200 E TROJAN WAY	90033	14	135A225   142	5202001009	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	34.06447	-118.20225	NEW FIRE ALARM SYSTEM FOR NEW 5-STORY COMMERCIAL BUILDING WITH 200 UNITS OF GUEST ROOMS. SCOPE OF WORK INCLUDES (1) FACP AND (352) FA DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
786	17041-20001-38433	14555 W OSBORNE ST	91402	6	195B149    97	2639007021	R4-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Apartment			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.23325	-118.44944	8/16/2018changes to an approved set of plans.  changes noted delta 6.  changes include addition of light fixtures and recalculation of energy compliance.This is plan check only.((((Plan check for energy only. Interior renovations to apartment building. New interior and exterior lighting. Total T24 area - 65,737sqft.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
787	13041-10000-30425	5801 N COSTELLO AVE	91401	2	174B153   279	2246015013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.17597	-118.43788	PV1 4.25KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: { SOLAREDGE SE3800A-US }]. [(17)modules: {Renesola {JC250M-24/BB}}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
788	18041-10000-31251	14530 W KESWICK ST	91405	6	186B149    49	2210031029	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.21016	-118.45006	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
789	11041-20000-23424	7238-7248 N CANBY AVE 1-98	91335	3	186B125   921	2119021045	(T)[Q]R4-1-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.20236	-118.5346	New fire alarm.  150 devices and control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
790	15041-20003-30865	687 S HOBART BLVD	90005	10	132B193   184	5093006033	(T)(Q)C2-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.0605	-118.30557	09/13/2017 Plan check for a lost set of revisions done to an approved set of plans. Scope of work and revisions is the same as below: feeder size changes to allow the use of the voltage drop requirements in the 2016 Title 24 Part 6 Building Energy Efficiency Standards. Request for modification to use the current code's voltage drop requirements granted by Michael Packard 01-03-2017.*****Previous Work Description*****Revisions to approved set.  Reduction in effective combined conductor circular mil area on main feeders to comply with voltage drop requirements in 2016 Title 24 Part 6 Building Energy Efficiency Standards.  Request for modification to use the current code's voltage drop requirements granted by Michael Packard 01-03-2017.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
791	19041-10000-32900	5800 N KELVIN AVE	91367	3	174B109   149	2151019029	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Issued	08/21/2019 12:00:00 AM	ADDRESS	34.17582	-118.58462	PC for PV1 per inspectors request, rooftop mounted system, system size is 7.6KWac. Scope of work is 25 modules (Hanwha Q-cells 325) with optimzers (Huawei SUN2000-375W), a central inverter (Huawei SUN7.6 KTL), with a panel derate to 175A. Note there is an exisitng PV system as well. Note: Partial permits for PV have been pulled under 19041-90000-29326	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
792	17041-20000-24213	153 S BURLINGAME AVE	90049	11	132B137   582	4406012002	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.05509	-118.49116	PV1.  Install roof mounted PV system sized 15.2 kW interconnected with MSP.  $0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
793	13041-10006-34279	21720 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.18733	-118.60234	FIELD REVISIONS: INCLUDED SIZE OF FEEDERS TO MMDS07; INSTALL DC PANEL THAT INTERFACES BETWEEN CHARGER AND DC BATTERY FOR DBHV	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
794	18041-20001-40728	956 N CORSICA DR	90272	11	126B133    21	4408010007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	34.04524	-118.50808	expeditepv1install roof mounted pv system sized 15.2KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
795	13041-20000-13854	4760 W SUNSET BLVD	90027	13	147B197   733	5543015021	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.09788	-118.29343	PLAN CHECK FOR MEDICAL FACILITY. REPLACING DUPLEX MEDICAL VACUUM PUMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
796	10041-20000-02771	1875 CENTURY PARK EAST 2130	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM	02/22/2010 12:00:00 AM		Permit Finaled	03/25/2010 12:00:00 AM	PIN	34.06139196	-118.41527843	T.I WORK IN 21 FLOOR UNIT 2130. THIS PLAN CHECK IS TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
797	11041-10000-03317	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	33.95887	-118.41869	NEW FIRE ALARM SYSTEM IN EXISTING 14-STORY HOTEL.      WILL INSTALL NEW FIRE ALARM ALONG-SIDE THE EXISTING AND REMOVE OLD FIRE ALARM ONCE NEW ALARM SYSTEM IS SIGNED OFF.SUBMITTING WITH FIRE DEPT. AT THE SAME TIME SO WILL SUBMIT ANY CHANGES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
798	16041-10000-43068	10250 W SANTA MONICA BLVD # 1670	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""House of Polish"" Ste. 1670.  Install new 45 KVA Xrfmr, and  panels, total area 1,129 sq.ft*New load 47A to DB-ELA41"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
799	15041-10000-17150	20940 W BURBANK BLVD 1st Flr	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.17302	-118.58923	Full plan check for medical office T.I located at 1st floor of a medical/ office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
800	14041-10000-24527	2867 W SUNSET PL	90005	10	133-5A201  80	5077013022	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			PC Info Complete	09/26/2014 12:00:00 AM	ADDRESS	34.0609	-118.2861	New methane mitigation system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
801	18041-20001-09817	11051 W PENDLETON ST	91352	6	198B173    32	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.23953	-118.37198	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
802	14041-10000-01835	7029 W WILLOUGHBY AVE	90038	4	144B181   803	5532010041	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.08719	-118.34253	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 1596 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
803	15041-20000-26933	21650 W OXNARD ST	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. 3681 SQFT, EMERGENCY LIGHTING. SUITE 2350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
804	19041-10000-48865	7802 N IRVINE AVE	91605	6	189B169   738	2311013013	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.21226	-118.38546	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 2.4KWdc (3KWac) USING 8 SILFAB SLA-M300 MODULES, SE P320 POWER OTIMIZERS & SE-3000H-US CENTRAL INVERTER. ESS TESLA POWERWALL. CONNECTED TO A 200 AMP EXISTING SERVICE & AN EXISTING PV1 SYSTEM..	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
805	19041-10000-16390	13605 W ROSCOE BLVD	91402	6	192B157   672	2637016026	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1204.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.22182	-118.42917	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
806	13041-10000-29534	18789 W WILLOWTREE LANE	91326	12	207B121   527	2728029074	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.26304	-118.54276	PV1.  Install 8.25 kW DC roof-mounted solar array, interconnect with main service panel.  Inverter: Fronius IG Plus V 7.5.  33 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
807	19041-10000-14374	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM			PC Info Complete	04/22/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	PLAN CHECK FOR TITLE 24 ONLY FOR ENTRY PLAZA IN THE COLISEUM. TOTAL EFFECTED AREA 1017 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
808	12041-10000-13787	1660 W VENICE BLVD	90006	1	126B197   184	5056022022	CM-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	34.04407	-118.29097	REMODEL INTERIOR & EXTERIOR OF EXISTING MCDONALD'S.  NO WORK ON EXISTING KITCHEN.  REMODEL EXISTING RR'S AND UPGRADE AS REQUIRED TO CONFORM TO ADA CODESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
809	16041-20000-32268	4019 N TUJUNGA AVE	91604	2	162B173   488	2368023023	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.14041	-118.37908	800 AMP SERVICE UPGRADE. DISTRIBUTION BOARD ONLY RECONNECT TO EXISTING PANELS A B C AND M.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
810	18041-20000-05692	806 S ROBERTSON BLVD	90035	5	135B169   195	4333015032	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.06257	-118.38338	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from restaurant to medical office. Total lighting area = 1,515 sq. ft.Note: Building application has been generated under 17016-20000-30984	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
811	18041-10000-42404	16149 W HART ST	91406	6	183B141   324	2224010042	QMR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.19765	-118.48521	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
812	18041-10000-38081	400 W 30TH ST	90007	9	120A203    86	5122018033	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.02393	-118.27577	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF EXISTING OFFICE FACILITY APPROX 2638 SFBuilding permit 18016-10000-22905	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
813	19041-10000-21593	361 E JEFFERSON BLVD	90011	9	117A205    13	5120016035	M1-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.01645	-118.26742	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
814	14041-10002-07484	6321 W HOLLYWOOD BLVD	90028	13	148-5A187 150	5546004013	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.10178	-118.32754	plan check for power and energy. Changes clouded under delta 3. Changes to SLD: main switchboard MSA shows 2 new adjacent tenants on middle section. added lighting inverter circuit. Changes to light fixtures and layout.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
815	11041-20000-21903	9700 N WOODMAN AVE #A8	91331	6	201B149   343	2644024025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.00, 1193.10	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	34.24599	-118.44723	T24 ENERGY TI BEAUTY SALON. PERMIT FOR NEW CKTS, NEW LIGHTING ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
816	12041-20000-08896	5670 W WILSHIRE BLVD 830	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.06222	-118.35208	Energy plan check for office spaceInterior non-structural tenant improvement work on 1,734 s.f. of existing office   area. New wall, power, lighting and finishes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
817	14041-20001-04722	17346 W BURTON ST	91325	12	192B133   355	2201012003	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.22005	-118.51145	Fee for Expedite ONLY.*****Roof mouted PV system with 5.75KW dc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
818	16041-20000-02251	18233 W CHATSWORTH ST	91326	12	207B125   266	2715009013	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.26468	-118.53046	Plan check for a PV1 roof-mounted PV system. System size is 6.0 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
819	13041-10000-33083	14824 1/2 W CHATSWORTH DR	91345	7	207B149     7	2615022***	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.26854	-118.4556	PV1.  Install 5.25 kW roof-mounted PV system, interconnect with main service panel.  21 modules: Trina Solar TSM-250PA05.18.  Transformerless inverter: SolarEdge SE5000A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
820	16041-10000-18376	1460 W 23RD ST	90007	8	123B197   405	5055002018	RD2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	07/30/2016 12:00:00 AM	ADDRESS	34.03501	-118.2906	PV1 5KW SYSTEM.  14 PANELS (CS6X -315P)INVERTER (5KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
821	13041-20000-18041	530 W 6TH ST 905	90014	14	129A209    78	5144004012	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			Corrections Issued	07/09/2013 12:00:00 AM	ADDRESS	34.04853	-118.25518	TI FOR EXISTING HIGHRISE OFFICE. TOTAL SQRFT 1847. SCOPE OF WORK IN SUITE 905	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
822	12041-10002-15263	400 W WORLD WAY 4b	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Expired	12/16/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	changes to approved set of plans: 2panels were changed to have feedthru subpanels. one luminaire changed from 1 socket to 3. added Device power for Food truck equipment. service load calcs changed. relocated some panels. moved switches. tied EF and MUA. added bugeye instead of battery backup for light. Located in Terminal 4, departure level, space 4B, foodcourt.New electrical panels and circuits for 5 new restaurants.  Full plan check for Power and Energy. TI previously restaurants converted to new food court including (N) partitions, millwork and ceiling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
823	18041-10001-38075	12616 W SHERMAN WAY	91605	2	183B161    62	2324020034	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM			PC Approved	07/22/2019 12:00:00 AM	ADDRESS	34.20097	-118.40799	"SUPPLEMENTAL CHANGES TO APPROVED SET DELTA ""C"" ONLY. CHANGES IN LAYOUT AND LIGHTING FIXTURES. <<<Tenant Improvement to existing Restaurant (Interior and Exterior). T-24 ONLY. BLDG PERMIT: 18016-10000-27310>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
824	14041-10001-08644	1901 W 6TH ST 1-53	90057	1	133-5A205 293	5154026001	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			06/27/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.05872	-118.27264	REVISIONS TO PERMITTED SET OF PLANS: LARGER GEN SET; INCREASED OF GEN SET FEEDERS; WSMALLER ELEVATORMOTOR WITH CHANGES  TO FEEDER. CHANGES ARE CLOUDED ON TH PLANS(((((PLANCHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION OF  53-UNIT AFFORDABLE APARTMENT BUILDING OVER BASEMENT PARKING WITH 5 STORIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
825	19041-10000-42713	12230 W DUNOON LANE	90049	11	129B141    93	4404005013	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	03/17/2020 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.05322	-118.47712	FEES ARE $0 DUE TO AB1414PV1. NEW ROOFTOP SOLAR SYSTEM WITH BATTER BACKUP. CONSIST OF 50 MODULES (33 x LUMOS 300 & 17 x L G 370), 50 OPTIMIZERS (SE P400) AND 3 CENTRAL INVERTERS (2 x SE7600A-US AND 1 x 38000H-US). SYSTEM INCLUDES 2 x LG CHEM BATTERIES. SYSTEM SIZE IS 16.19 KW DC AND 19KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
826	18041-10000-38959	11828 W SAN VICENTE BLVD	90049	11	129B145   122	4265018009	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			Corrections Issued	10/11/2018 12:00:00 AM	ADDRESS	34.05269	-118.46895	PLAN CHECK ONLY FOR T24, T.I. FOR FAST CASUAL RESTAURANT.  NEW CONNECTED LOAD < 200A, INSTALL (3) NEW PANELS, NEW POWER AND LIGHTING, TOTAL AREA 3,125 SQ.FT(B# 18016-10000-33019)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
827	18041-20002-44048	5158 N CALVIN AVE	91356	3	171B117   265	2163007023	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Issued	11/30/2018 12:00:00 AM	ADDRESS	34.16547	-118.5551	11-30-2018 Changes to an approved set of plans, Changes include reduction of PV modules from 48 to 40 PV Modules. $0.00 permit fee due to State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
828	11041-10000-13604	6750 W SUNSET BLVD	90028	13	147A185    92	5547021001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Closed	09/02/2011 12:00:00 AM	ADDRESS	34.09769	-118.33815	NEW FIRE ALARM SYSTEM FOR A NEW BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
829	11041-20000-11972	10100 W SANTA MONICA BLVD #2500	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM			PC Approved	06/10/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	T.I. to existing high rise building.  Install general/emergency lighting in partial of suite 2500.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
830	12041-20000-14219	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to high rise building on 21st, 22nd, and 23rd floor of common restrooms and conference room.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
831	14041-10001-32802	5942 N LANKERSHIM BLVD	91601	2	177B169   916	2338010025	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			12/26/2014 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	34.17874	-118.38277	Plan check for power and energy. Project site is an existing dental office. Project scope is remodeling of the dental office, including patient care areas. Total lighting area = 950 sq. ft. PERMIT OBTAINED ON 14041-10000-32802(((INSTALL 50 OUTLETS AND 8 SWITCHES.  NO LIGHTING.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
832	19041-20001-09377	2930-2936 E CESAR E CHAVEZ AVE	90033	14	127-5A227 253	5180019048	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			PC Approved	04/30/2019 12:00:00 AM	ADDRESS	34.04342	-118.20083	Plan check for power and energy for medical office.  Revisions made to lighting system.  (((T24 PLAN CHECK FOR EXISTING DENTAL OFFICE, INSTALLING LED LIGHTS AND OUTLETS, USING EXISTING BRANCH CIRCUITS, TOTAL SQUARE FOOTAGE = 1898 SF)))_	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
833	14041-10000-25768	700 N ALAMEDA ST	90012	14	132A215   180	5409023930	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	05/15/2016 12:00:00 AM	ADDRESS	34.05488	-118.23748	PC FOR POWER. PROVIDING 8 KW UPS IN EACH TELE COLSET WITH BRANCH CIRCUITS FED FROM MAIN BUS.PLANCHECKER REVERIFY THE FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
834	13041-10001-22267	20009 W GYPSY LANE	91364	3	168B113   289	2175018010	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.15691	-118.56903	EXPEDITE PLAN CHECK PER APPLICANT REQUEST.----------INSTALL ROOF TOP SOLAR ARRAY INTERCONNECT WITH APIN PANEL SYSTEM SIZE 15.19 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
835	18041-20000-47527	643 N MARIE AVE	90042	14	157-5A231 111	5483012024	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Expired	11/15/2023 12:00:00 AM	ADDRESS	34.12709	-118.18162	Plan check for the addition of (1) battery back-up unit onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
836	17041-10000-11450	450 S WESTERN AVE 307	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.06562	-118.30887	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT(RESTARANT)PLAN CHECK INCLUDES CONNECTING TO AN EXISTING DISTRIBUTION BOARD, NEW PANELS, AND TOTAL SQ. FT. 1076	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
837	15041-10000-06147	8517 N KESTER AVE	91402	6	192B149   144	2653014012	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Expired	07/12/2017 12:00:00 AM	ADDRESS	34.22526	-118.4576	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.0KW INTERCONNECTED WITH MSP.  (33) ENPHAE M215 MICROINVERTERS(33) LG 280S1C-B3 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
838	19041-10000-28493	846 S MARIPOSA AVE	90005	10	132B197   715	5094017002	R4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.05	Electrical	Electrical	Apartment			07/24/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.05637	-118.29858	PC for FA system for a new apartment. 1 FACP and 96 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
839	11041-10000-23411	1041 N HIGHLAND AVE	90038	4	144B185   819	5532027008	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.09003	-118.33878	T.I. to a commercial dog hotel on the first floor only.   PLAN CHECK ONLY for Energy, no emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
840	19041-20000-23677	18339 W EDDY ST	91325	12	195B125   897	2786002038	M1-1VL, PF-1XL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	10/14/2022 12:00:00 AM		Issued	10/14/2022 12:00:00 AM	ADDRESS	34.22781	-118.53256	service upgrade 1600 amp distribution board only, plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
841	17041-20000-37278	16628 W DEARBORN ST	91343	12	198B137   805	2687025008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.23741	-118.49477	ENERGY STORAGE SYSTEM 13.5 KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
842	17041-10000-14722	5850 W FRANKLIN AVE	90028	13	150A191   187	5586028028	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Info Complete	05/04/2017 12:00:00 AM	ADDRESS	34.10502	-118.3172	T24 FOR PARKING LOT. SITE LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
843	13041-20000-18106	16226 W BERTELLA DR	91436	5	168B137   793	2284016041	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.15326	-118.48675	solar single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
844	12041-20002-09896	5080 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	06/14/2013 12:00:00 AM	ADDRESS	34.02028	-118.35491	"Modification to approved set of plans for ""Delta R2"" only.  No load changes per applicant.  Only relocating lights and receptacles.<<<<Changes to approved set of plans. Changes to electrical room, addition of ""temporary power"" on 1-line (see E6.2). List of changes has been included and all changes have been clouded on plans. Relocation of ""Hand dryer"" from LN-28,30 to LNA-9,11. 4 new circuits (HA-32, LN-28,30,32).Remodel. Ralph's store. Plan check for power and energy. 59333 SF condtioned and 20575 exterior SF. Single story commercial grocery store building.>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
845	19041-20000-28957	11910 W ANETA ST	90230	11	105B161   161	4220018029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.9871	-118.40622	Plan check for PV roof mounted system, system size: 2.31 KW DC, 2.095 KW CEC AC with 7 PV Modules and 4 micorinverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
846	17041-10000-13418	20905 W ROSCOE BLVD	91304	3	192B109   747	2779007011	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.22009	-118.58889	PC for energy only. Indoor Title 24. Change of use take out restaurant to restaurant with seating. Installing new lighting and power. Total area: 1,625.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
847	17041-10000-22471	9454 N GIERSON AVE	91311	12	198B101    50	2727020020	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.24241	-118.61131	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 12.395 kWac.  AC module system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
848	17041-10000-18033	11315 N WHITE OAK AVE	91344	12	213B129   375	2711017019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.27634	-118.51991	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - TOTAL OF (22) FIXTURES. TOTAL SQ. FT. 64725	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
849	11041-10000-05936	2500 N PASADENA AVE	90031	1	139-5A221 197	5204003022	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Approved	04/04/2011 12:00:00 AM	ADDRESS	34.07622	-118.21616	Ti in an existing restaurant. EPC is for T24 & emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
850	19041-20000-31807	809 E 5TH ST	90013	14	127-5A213 407	5147011024	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.0425	-118.24083	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN EXISTING LOW RISE COMMERCIAL BUILDING. SCOPE OF WORK CONSISTS OF (1) FA PANEL AND (150) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
851	14041-20000-25173	251 N BUNDY DR	90049	11	135B141   780	4402021024	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.06301	-118.47671	PV1STANDARD PLAN CENTRAL TRANSFORMERLESS INVERTER .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
852	17041-20000-16265	18740 W KIRKCOLM LANE	91326	12	216B121    86	2870007007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Issued	05/23/2017 12:00:00 AM	ADDRESS	34.29229	-118.54173	pv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
853	19041-10000-05334	7800 S VERMONT AVE	90044	8	099B197   438	6020013900	C2-1VL	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	33.9686	-118.29131	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
854	15041-10000-16433	671 S ANDERSON ST	90023	14	124-5A219 139	5171020007	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.03591	-118.22336	Change of use from light manufacturing to brewery.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
855	15041-20000-22297	10639 N SEPULVEDA BLVD	91345	7	207B145   352	2649012003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.26384	-118.46775	Plan check for core and shell for existing retail with service upgrade form 3phase 240V at 400A to 3phase 480V at 600A and outdoor lighting area: 53,300 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
856	17041-20000-13552	4157 N VERDUGO ROAD	90065	14	157-5A217 144	5459025013	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	34.12656	-118.23231	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.This is plan check only.  permit fees paid under application number 17041-20000-05674	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
857	13041-10000-14304	2137 N BANYAN DR	90049	11	138B133   278	4492010015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.07468	-118.50253	PV1.  Install new 17.64 kW DC roof-mounted solar array, interconnect with main service panel.  {72 modules: Trina Solar TSM-245PC05/PA05.18} {2 inverters: Fronius IG PLUS V 7.5 and V 5.0}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
858	17041-10002-05785	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Issued	12/18/2017 12:00:00 AM	ADDRESS	34.23342	-118.3809	PC FOR REVISON TO APPROVED SET UNDER DELTA 5 TO REFLECT CHANGES IN FIELD.SCOPE INCLUDES MINOR CHANGES TO CONDUIT AND CONDUCTOR INFORMATION, LABELS AND SIZING.REDUCTION IN HP TO SOME MOTORS ON PANEL HXSOME ADDITIONAL NOTES ADDED ON THE PLAN AND TWO NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
859	16041-20001-30563	2231 W 28TH ST	90018	10	123B189   985	5052018026	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			Reviewed by Supervisor	09/12/2016 12:00:00 AM	ADDRESS	34.03004	-118.31576	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar array on a SFD. Interconnect with a 125A msp. 6kW ungrounded system. (20) 327W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
860	19041-20000-39699	611 N LARCHMONT BLVD	90004	4	141B189   584	5523012026	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.08205	-118.32385	New fire alarm system for renovated commercial building.  (115) devices, FACP, and annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
861	18041-20000-27277	3426 W MADERA AVE	90039	13	153B209   593	5437009005	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.11511	-118.26017	Plan check for the addition of a Tesla PowerWall onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
862	17041-20000-46104	21240 W BURBANK BLVD BLDG 33	91367	3	174B105    40	2149016026	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.17307	-118.59314	New 500 kVA medium voltage transformer for reconnection of (E) building feeder.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
863	19041-20000-31645	14608 W ISLA VISTA DR	91402	6	201B149   890	2650019063	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.2474	-118.45073	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON A NEW SFD. SYSTEM SIZE IS 3.15KW DC/2.835 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
864	19041-10000-50788	2581 E CHAUCER ST BUILDING 1	90065	1	145-5A217 517	5445031***	[Q]CM-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	09/03/2020 12:00:00 AM		Permit Finaled	11/22/2021 12:00:00 AM	PIN	34.0949861	-118.23281575	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A SERVICE OF 600A AND 225A, 120/208 V, 3-PHASE 4W FOR BUILDING 1 AND REC ROOM. TOTAL AFFECTED AREA IS 32432 SQ FT5 BUILDINGS ARE CONNECTED TO 1 SERVICE SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
865	18041-20000-10485	15154 W GAULT ST	91405	6	183B145  1130	2220022020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.19914	-118.46391	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac/5.2 kWdc and consists of (16) modules, (16) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
866	15041-20000-28632	11062 N WINNETKA AVE	91311	12	210B113    69	2708021009	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.27121	-118.56932	Installation of new roof mounted solar PV array.  Total system size = 34.2 kWac.  System consists of 160 Solar World 250 W modules divided into 8 strings connected to 3 Solar Edge SE 11400A inverters.  Existing 600 A MSP to have main breaker derated to 500 A.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
867	11041-20000-22485	15451 W VENTURA BLVD	91403	5	168B145   754	2261039023	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM			PC Approved	10/20/2011 12:00:00 AM	ADDRESS	34.15473	-118.47062	T.I.  New light fixtures for a lounge.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
868	18041-10000-09785	20826 W TULSA ST	91311	12	210B109   352	2706008036	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.26798	-118.58739	PC FOR INSTALLATION OF NEW ESS. SCOPE INCLUDES ONE TESLA POWERWALL  WITH (1) NEW LOAD SUBPANEL. RESIDENCE HAS EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
869	17041-10000-23251	1541 W WILSHIRE BLVD #430 &-RESTROOMS	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	06/06/2018 12:00:00 AM		Issued	06/06/2018 12:00:00 AM	ADDRESS	34.05529	-118.26949	PC FOR Office Tenant Improvement FOR TITLE-24  ENERGY ONLY IN RESTROOM AND OFFICE SPACE. NEW LIGHT AND RECEPTACLES. TOTAL AFFECTED AREA 672 SQ.FT. BL # 17016-10000-15940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
870	19041-10000-45818	4960 E HUNTINGTON DR SOUTH #103-#105	90032	14	144A235   333	5218009020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.08745	-118.17453	PLAN CHECK ONLY FOR T24 ONLY, SCOPE OF WORK IS NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2854 SFQT. NOTE PERMIT FEES HAVE BEEN PULLED UNDER 19041-10K-39423	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
871	13041-10000-09665	624 S GRAND AVE	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	PIN	34.04778206	-118.25563275	UPGRADE OF DISTRIBUTION BOARDS AND TRANSFORMERS. RATING OF EQUIPMENT > 600 A. PC FOR POWER ONLY. NEW FEEDERS. NO NEW CIRCUITS, LEFT FOR FUTURE IMPROVEMENTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
872	17041-20000-24181	19301 W NORDHOFF ST	91324	12	198B117   217	2761037019	C4-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.23566	-118.5541	New single story commercial building (Starbucks). 600 amp service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
873	16041-10000-03508	4014 S PUNTA ALTA DR	90008	10	114B177    63	5029030016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Refund in Progress	07/28/2016 12:00:00 AM	ADDRESS	34.01189	-118.35959	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.2KWac. (64)MODULES-CANADIAN SOLAR CS6P-265P(64)OPTIMIZERS-SOLAR EDGE POWER P300(2)INVERTERS-SOLAREDGE TECHNOLOGIES SE 7600 WATTNote: Fee $0 due SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
874	18041-20000-20338	10830 W CHALON ROAD	90077	5	141B149   158	4369022002	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM			PC Approved	02/25/2019 12:00:00 AM	ADDRESS	34.08252	-118.45528	Plan check for Power only for new Single Family Dwelling 3 story building. Service size 1000APlan check only. Permit pulled under Building application 16010-10000-05072	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
875	15041-20000-02850	12468 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	33.97899	-118.41015	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
876	15041-20000-27173	19429 W KINZIE ST	91324	12	201B117   189	2761010015	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.24879	-118.55661	PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel. (46) Hyundai HIS-S270(2) ABB PVI-6000 Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
877	14041-20002-23920	12801 W DESMOND ST	91331	7	216B161   157	2527011028	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	34.2884	-118.41142	FEE CHARGE $0.00 BY STATE SENATE BILL NO.1222REVISIONS TO AN APPROVED SET OF PLANS.  MAIN PANEL DERATE FROM 200 TO 175 AMP PER INSPECTOR GALLAGHER REQUEST. PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 10kW.(2) Aurora PVI-5000-OUTD-S-US-A transformerless inverters(30) Sunpower 327W pv modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
878	15041-10000-08369	355 S GRAND AVE 1675	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.05191	-118.2525	Plan check for energy only. permit to be pulled at EPC counter only. Less than 400A. Includes Emergency lighting. INTERIOR TENANT IMPROVEMENT for office ON SUITE 1675. BLDG#: 15016-10000-05958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
879	19041-20001-36748	5727 N CANOGA AVE BLDG 12	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	10/14/2020 12:00:00 AM	ADDRESS	34.17529	-118.5978	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
880	19041-20000-15565	5900 W WILSHIRE BLVD Suite 600	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for Title 24 only. Project site is a part of the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,406 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
881	16041-10000-24787	12663 W FILMORE ST	91331	7	213B161   439	2527029015	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Expired	08/22/2018 12:00:00 AM	ADDRESS	34.28091	-118.40933	PC FOR PV SYSTEM, ROOF MOUNTED SOLAR. TOTAL SIZE 3.8KW AC USING CENTRAL INVERTER SYSTEM AND TOTAL OF 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
882	14041-10000-32933	772 E 12TH ST 2	90021	14	123A211    78	5132012026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.03244	-118.25114	Energy plan check for a commercial area by replacing HID to LED fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
883	15041-20000-04266	16420 W PLUMMER ST	91343	12	198B137    85	2676010014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.24279	-118.49004	pv1central string inverter standard plan system sized 5.0kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
884	14041-20000-00401	5107 W HAROLD WAY	90027	13	148-5A195 238	5544013008	RD1.5-1XL	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			01/07/2014 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.09947	-118.30083	NEW 7 UNIT APARTMENT BUILDING. SERVICE SIZE 600A. plan check in accordance to 2008 NEC due to building submittal	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
885	16041-20000-02318	16300 W LINDBERGH ST	91406	6	189B137    52	2205004026	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.21438	-118.48801	Plan check for Title 24 only for existing space T.I. Total area 5091 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
886	17041-10002-28729	11950 W FOOTHILL BLVD	91342	7	210B165    41	2532012039	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.2757	-118.3967	DELTA 10 CHANGES TO APPROVED PLANS FOR ADDING 7 NEW SHOW WINDOW RECEPTACLES.<<<<Plan check power and energy for Interior TI (planet fitness) - change of use from retail/grocery to fitness center/gym. Scope includes new panels circuits, equipment and lights (incl. emergency)Total affected area indoor 19,779sqft.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
887	16041-10000-34084	18804 W NORDHOFF ST	91324	12	198B121   810	2770002012	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.23526	-118.54273	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(21)MODULES-HANWA Q-CELL. Q PEAK=G3 280(1)INVERTER-SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
888	17041-20000-23102	4400 N CAHUENGA BLVD	91602	4	165B177   345	2424002005	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			07/10/2017 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	34.15059	-118.36128	Plan check for power and energy. Project scope is a 3-story, 10-unit apartment building over a basement parking garage. Work includes an 800-amp service and a total lighting area of 11,860 sq. ft.Note: Building application has been generated under 17010-20000-00901	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
889	12041-10001-06171	1103-1109 S BOYLE AVE	90023	14	123A219    19	5170007015	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.03162	-118.2203	DELTA 4 & 5 CHANGES TO THE APPROVED PLANS. <<Proposed 1 story with mezzanine (type III-B) warehouse building with accessory office (shell only).  Tenant improvement is an separate permit.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
890	10041-10000-23507	301 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Closed	05/17/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY  ( 2-DAYS ) STANDBY GENERATOR  TO SUPPLY POWER TO EACH OF TWO MCC WHICH POWERS EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
891	14041-20000-25436	4303 N BEEMAN AVE	91604	2	165B161   602	2375003021	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.14874	-118.40744	PERMIT FEE $0.00 BY STATE SENATE BILL.PV1CENTRAL INVERTER STANDARD PLAN SIZED 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
892	18041-10000-31237	14326 W OXNARD ST	91401	4	177B153   910	2245017028	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.17924	-118.44512	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
893	14041-10000-25169	1150 S BEVERLY DR	90035	5	132A167   103	4330031040	C2-1VL-O, R4-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			PC Approved	09/26/2014 12:00:00 AM	ADDRESS	34.05621	-118.39569	Title 24 plan check only.  Total area = 15,675 sq. ft.Renovation of lighting and recepticles for restaraunt space in a 12 story highrise hotel building.Fire alarm will be a seperate submittal.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
894	14041-10000-17171	601 S FIGUEROA ST #500	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.05076	-118.25881	Title 24 plan check only.  Total area = 5,386 sq. ft.TI to existing highrise office space.  Move a pannelboard from the 4th floor to the 5th floor and add lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
895	16041-10000-27947	14006 W RIVERSIDE DR #228	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1525 SQ. FT. B#16016-10000-16565	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
896	15041-20000-26075	23715 W HAYNES ST	91307	12	180B093   434	2034023048	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.18998	-118.64339	PV1. Install roof mounted PV system sized 4.2 kW. Interconnected with main service panel. (21) Toina Solar tsm-255 Modules(1) ABB PVI-4.2 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
897	17041-10000-34026	330 S ALAMEDA ST	90013	14	127-5A215 134	5163010007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.04394	-118.23787	PC FOR A NEW FIRE ALARM PANEL WITH 15 DEVICES TO A COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
898	18041-20000-31345	9376 W READCREST DR	90210	4	147B165   564	4352012019	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.09564	-118.40394	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of a battery back-up system to an existing PV system. Battery back-up system is the sonnenBatterie eco 20.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
899	13041-20000-27291	7658 N LENA AVE	91304	12	189B097  1181	2014020023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Expired	11/02/2015 12:00:00 AM	ADDRESS	34.21	-118.62578	(((ZONING COMPLETED ON ORIGINAL APPLICATION#: 13041-10000-24044)))PV1. ROOF MOUNTED SOLAR ARRAY. CENTRAL INVERTER. SYSTEM SIZE: 6.615 KW. 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
900	19041-20000-00060	1500 N GILCREST DR pv1	90210	4	147B165   360	4352009054	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.09796	-118.40202	pv1install roof mounted pv system sized 20KW AC interconnected with msp.20.40KW DC, 18.20 KW AC CEC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
901	16041-10000-35856	318 E 2ND ST #B	90012	14	129A213   100	5161022012	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.04881	-118.24129	T-24, PC FOR ENERGY ONLY. CHANGE OF USEA PORTION OF THE 1ST FLOOR (E) RESTAURANT (COCKTAIL LOUNGE) TO T-MOBILE RETAIL, OFFICE  AND STORAGE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1445 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
902	17041-10000-17365	930 N FIGUEROA TER	90012	1	136-5A213 137	5406025058	R4-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.06712	-118.24383	PC for upgrade of section of existing service. AIC to match existing. new 1600A to accomodate solar input.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
903	17041-10000-18935	1881 N MORTON AVE	90026	13	142-5A211 164	5420025001	[Q]RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM			Corrections Issued	06/06/2017 12:00:00 AM	ADDRESS	34.08511	-118.24963	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
904	12041-10001-25781	814 N TOULON DR	90272	11	126B133    72	4408014022	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2013 12:00:00 AM			Corrections Issued	11/01/2013 12:00:00 AM	ADDRESS	34.04408	-118.50973	][][]CHANGES MADE TO AN APPROVED SET OF PLANS UNDER PC# 12041-20000-25781; CHANGES IS FOR REMOVAL OF BATTERY SYSTEM, RELOCATING OF DISCONNECTS AND INVERTER, REMOVAL OF FEED FROM BATTERY TO EMERGENCY LOAD ][][][][Photovoltaic system with battery charger system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
905	15041-10000-43896	6910 W GRENOBLE ST	91042	7	207B201   275	2553011010	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM			Reviewed by Supervisor	01/20/2016 12:00:00 AM	ADDRESS	34.26075	-118.28151	PV1, INSTALLL 4.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER X21-345(1) INVERTER: SOLAREDGE SE3800A-US 240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
906	18041-20001-22242	7530 N VAN NUYS BLVD	91405	2	186B149   193	2215001008	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM			PC Approved	05/17/2019 12:00:00 AM	ADDRESS	34.20782	-118.44856	5/17/2019changes to an approved set of plans.  changes to service 600 amp and 600 amp rated MCC.  No new loads.This is plan check only.  ((((New 600A 480Y/277V 3ph-4w service for (E) carwash.  Replacement of 400A MCC and associated motor loads.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
907	13041-20000-29235	7860 W MCGROARTY ST	91040	7	204B193  1383	2559027008	RE15-1, RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.25223	-118.30479	PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING SINGLE TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS. USING 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
908	17041-10000-07408	10201 W PICO BLVD STAGE 6	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	PC FOR POWER, INSTALATION OF FOUR NEW 800A COMPANY SWITCHES ON SOUND STAGE 6 FOR CONNECTION OF TEMP SET LIGHTINGCIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
909	19041-20002-36656	10350 N NEWHOME AVE	91040	7	204B189   305	2560002023	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.2574	-118.32089	12-30-2019 Changes to an approved set of plan, Changes include update main service panel. to 225A panel with 200A main circuit breaker. Changes has been clouded. Plan check only. Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
910	19041-10000-08025	12154 W MONTAGUE ST	91331	7	204B165    89	2537018027	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	03/02/2022 12:00:00 AM	ADDRESS	34.25712	-118.39806	PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 1998 MODULES (Q-PEAK 395), 1026 OPTIMIZERS (P850 ) AND 6 INVERTERS ( SE 99.9K). SYSTEM SIZE IS 600KWac AND 789.2KWdcPERMIT FEE IS $ 0 IN ACCORDANCE WITH AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
911	19041-20000-00117	603 S MANSFIELD AVE	90036	4	135B181   580	5507021001	R1R3-RG	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	03/16/2019 12:00:00 AM	ADDRESS	34.0647	-118.34089	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWdc/5 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
912	14041-10000-31239	523 N AVALON BLVD	90744	15	030B205   951	7418005014	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	33.77642	-118.26241	Full plan check for a shell design including new 600-Amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
913	17041-10001-30916	7083 W HOLLYWOOD BLVD #100	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.10173	-118.34439	PC for T24 only for addition of lights in existing editing room. Permit fees where paid under 17041-10000-30916.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
914	16041-20001-37480	19230 W HATTERAS ST	91356	3	174B117   125	2156005002	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			PC Approved	11/17/2016 12:00:00 AM	ADDRESS	34.17566	-118.55285	EXPEDITEpv1install roof mounted pv system sized 13.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
915	18041-30000-43468	2029 S CENTURY PARK EAST 2ND FLOOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Re-Activate Permit	12/24/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT, RENOVATION OF A PUBLIC ELEVATOR LOBBY 2ND FRL. NEW LIGHTS WILL CONNECT TO THE EXISTING BRANCH CIRCUIT SERVING THE AREA. TOTAL AREA: 295 SQ.FT(B# 18016-10000-25397)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
916	13041-20000-27230	970 W 190TH ST Suite 215	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	33.85812	-118.29302	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 215. TOTAL SQRFT 1475	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
917	15041-20000-00667	6510 E ELGIN ST	90042	14	154-5A233 192	5493019015	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.1175	-118.17785	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system.12  327W pv modules across two strings (6+6).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
918	17041-10000-43801	15312 S VERMONT AVE	90247	15	072B197   145	6120003020	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	33.89206	-118.2915	REPLACE HID OUTDOOR FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
919	10041-10000-23242	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	Ti in a restaurant. New Panels, X-former and a UPS. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
920	19041-20000-07700	16521 W SATICOY ST	91406	6	186B137    22	2205009009	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.20858	-118.49305	PV3.  Install 103.295 kW DC / 93.331 kW AC-CEC roof mounted grid tied PV system.  (283) modules with (1) 33.3 kW and (3) 20 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
921	19041-10000-00277	915 W 68TH ST	90044	8	102B197   343	6013009015	RD1.5-1	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	33.97831	-118.28972	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 12 MODULES (Q-PEAK 315W) , 12 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.78KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
922	14041-10000-03008	11111 W SANTA MONICA BLVD SUITE 400	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLANCHECK FOR T24 ENERGY. OFFICE TI. NO CHANGE IN OCCUPANCY. 11403 SQFT, EMERGENCY LIGHTING. HIGH RISE. SUITE 400 ON 4TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
923	12041-10000-21470	4144 N WOODCLIFF ROAD	91403	5	165A145   156	2281002003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.1459	-118.4671	3.43 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
924	14041-20001-11616	20004 W PARTHENIA ST	91306	3	195B113   592	2782012010	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	PIN	34.22770499	-118.56903649	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS INVERTER. SYSTEM SIZE: 6 KW DC.(24) HYUNDAI M250(1) POWER-ONE PVI-6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
925	19041-20001-29321	15437 W BLEDSOE ST	91342	7	222B145   315	2604016007	RA-1-K	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	34.30248	-118.46896	Plan check for 1.55 kW roof mounted grid tied PV system.  (E) 3.8 kW PV system on site.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
926	17041-20001-18440	11824 N STEWARTON DR	91326	12	216B121   372	2872023018	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			PC Approved	06/13/2017 12:00:00 AM	ADDRESS	34.2874	-118.54009	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
927	13041-10001-27137	20200 W TUBA ST	91311	12	204B113   298	2741010011	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.25592	-118.57369	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 5.25 kW. TRANSFORMERLESS INVERTER. TWO STORY.(21) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-5000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
928	11041-10000-27691	750 E SLAUSON AVE	90001	9	108B205  1507	6007002030	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM			PC Approved	12/30/2011 12:00:00 AM	PIN	33.98868539	-118.26217186	Install general lighting in restroom area.  Plan check for energy only.Note: Permit is under 11041-10001-16807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
929	13041-20000-31345	10811 W FOOTHILL BLVD	91342	7	210B173    62	2529021006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.27469	-118.36665	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
930	17041-10000-04279	2945 E 12TH ST	90023	14	118-5A221  12	5169007017	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.02001	-118.2153	Plan check for Title 24 only in existing remove indoor and outdoor HID lihgting fixtures and replace with new LED lightfing fixtures. Total indoor and outdoor area: 42,750 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
931	11041-10000-24312	555 W 5TH ST 47TH FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
932	12041-10000-16217	19427 W BRAEWOOD DR	91356	3	162B117   233	2180015004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	09/12/2012 12:00:00 AM	ADDRESS	34.13996	-118.55749	New rooftop 10.08kw photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
933	14041-10000-30050	1901 S AVENUE OF THE STARS 2ND FLOOR	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	34.05949	-118.41705	Energy plan check for a T.I office in a high rise building. work includes adding new light in new office, total work area is 1850 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
934	18041-10002-20929	20747 W DEARBORN ST	91311	12	198B109   144	2748036022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.23734	-118.58591	Resubmittal of rooftop (PV2) solar system due to lost original plan and design change.SOW: System ize is 48 kW AC, install:           (4) inverters Fronius Symo 12 kW 3ph, 240V            (176) Modules CS3U-370MS            (1) 200A PV dedicated subpanel((Original plan was approved under 18041-10000-20929))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
935	18041-10001-30728	3019 S WEST VIEW ST	90016	10	120B177   642	5049034038	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.02629	-118.35335	PC FOR FA  ADDING 62 DEVICES TO 4TH FLOOR TO AN APPROVED SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
936	17041-20000-40665	685 N AMALFI DR	90272	11	126B129   634	4408018001	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM			PC Info Complete	12/21/2017 12:00:00 AM	ADDRESS	34.04034	-118.51249	SFD addition.  New 600 A 120/240V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
937	14041-10001-03888	8651 N GULLO AVE	91402	6	192B157    59	2627027105	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.22668	-118.42451	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. {{PV1, Install 5.75 kW DC roof-mounted solar array for one-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 5000A-US. (23) Modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
938	12041-10000-22149	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM			Reviewed by Supervisor	10/23/2012 12:00:00 AM	ADDRESS	33.89279	-118.28725	New restaurant. 600 amp new service, new panels, and ckts. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
939	11041-20000-23351	2030 N DRACENA DR 1-35	90027	4	150B197   379	5590006034	R3-1XL	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Apartment			11/01/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.10857	-118.2901	New 21 KW roof mounted solar system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
940	12041-20000-09575	1880 S CENTURY PARK EAST ROOF	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.06144	-118.41437	Replacement of existing generator. 230kV, one 150A transfer switch and one 400A transfer switch. Plan check for power.   Relocate light switch P2 fuel delivery room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
941	14041-10000-16894	334 W AVENUE 44	90065	1	147A223   137	5465012012	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Expired	08/02/2016 12:00:00 AM	ADDRESS	34.09762	-118.21056	PV1,  INSTALL 3.57 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) INVERTER: SOLAREDGE # SE3000A-US-ZB-U(14) MODULES: TRINA SOLAR TSM-225PA05.18	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
942	19041-10000-47699	11116 W CHARNOCK ROAD	90034	5	117B157   385	4252006025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	01/29/2020 12:00:00 AM	ADDRESS	34.01708	-118.41962	ADDING NEW OUTDOOR LIGHTING FIXTURES THAT REQUIRES TITLE 24 PLAN CHECK, 3 GENERATORSAND  A 200 PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
943	12041-20000-00172	13286 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM	01/04/2012 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	33.97878	-118.43604	T.I. TO (E) VETERINARY CLINIC.  (1949 SF).   NON BEARING PARTITIONS/ T-BAR CEILING AND RELOCATE DAS RESTROOM.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
944	11041-10000-09605	747 E 10TH ST	90021										Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/11/2011 12:00:00 AM	ADDRESS	34.03509	-118.25044	REMODEL EXISTING RETAIL SPACE-RELOCATE PANELS AND ADD NEW CKTS AND LIGHTING FIXTURES IN UNIT #'S 114, 214, 116, 119, 216 & 219. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
945	17041-10001-43134	757 S ALAMEDA ST BLDG 3	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM			PC Approved	04/27/2018 12:00:00 AM	ADDRESS	34.0318	-118.23916	Changes to approved set noted as Delta-3. Scope includes reducing total device by 17 from the originally approved plan. This is plan check only, permit is covered under master #17041-10000-43134<<Install new Fire Alarm system on Building 3 only, this system will connect to the (E) main control panel. (9) FA panels, (467) FA devices>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
946	14041-10000-31974	200 WORLD WAY T01-FB	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Installation of LED signs for a coffee shop kiosk in concourse.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
947	16041-20000-34812	22043 W SAGEBROOK ROAD	91311	12	207B101   544	2723023006	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.26508	-118.60769	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.9 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
948	16041-10001-38969	1279 S UNION AVE	90015	1	127-5A203  62	5137033029	[Q]C2-1	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.04508	-118.27693	"T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM TAKE RESTAURANT TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS FOR DINING AREA. TOTAL AFFECTED AREA IS 999 SQ. FT. ""COMPLY WITH DEPARTMENT ORDER effective date 05/09/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
949	17041-20000-46509	4448 N VAN NOORD AVE	91604	2	165B161   119	2362013013	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.15183	-118.41483	INSTALLATION OF ENERGY STORAGE SYSTEM. SYSTEM SIZE: 10KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
950	13041-20000-02874	5670 W WILSHIRE BLVD # 1220	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.06222	-118.35208	T-24 and emergency lighting plan check for suite 1220.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
951	15041-20001-23096	17517 W WEDDINGTON ST	91316	5	171B129   103	2257004060	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.1669	-118.51503	EXPEDITE FEESPC FORPV SYSTEM. 26.1KW AC USING 4 INVERTERS TOTAL. SYSTEM IS UNGROUNDED. TOTAL OF 74 MODULES IN TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
952	10041-10000-08140	725 S FIGUEROA ST 39th floor	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.04886	-118.26071	Ti in an existing highrise. PC for T24 and Energy. (Variance was submitted to separate the Fire alarm system )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
953	12041-10000-08662	3130 W OLYMPIC BLVD	90006	10	129B193   325	5080025030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM			PC Approved	04/17/2012 12:00:00 AM	ADDRESS	34.05241	-118.30391	T.I. to an exisiting Hair Saloon.  Load is less than 100A.  PLAN CHECK ONLY for Energy.  ALL EMERGENCY LIGHTING IS EXISTING APPROVED, PER APPLICANT AND NOT PART OF THIS PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
954	13041-10001-36017	10429 N WHEATLAND AVE	91040	7	204B177    38	2542006002	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.2591	-118.358	Expedited RSES plan check per aplicant request.{{PV1, Install 4.25 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3800A-US. (17) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
955	14041-20000-02897	8847 N LANKERSHIM BLVD	91352	6	195B169   296	2631012060	(F)CM-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.23042	-118.38797	T24 FOR CHANGE OF USE TO DAYCARE CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
956	16041-20001-18554	5419 N TAMPA AVE	91356	3	174B117   599	2163014020	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM			PC Approved	05/31/2016 12:00:00 AM	ADDRESS	34.16954	-118.5536	RSES expedited plan check per applicant request.  PV1.  Install 11.77 kW roof mounted PV system.  (34) 327 W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
957	14041-20001-14207	1250 W VALROSE CT	90041	14	162A229   199	5690007042	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.13781	-118.19428	Plan check only for relocating inverter and dc disconnect.fee is 0.00 base on senate bill 1222(((PV1.  Install 5.0 kW roof-mounted utility-interactive PV system.  Transformerless inverter w/ power optimizers.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
958	12041-10000-30180	1539 S BELOIT AVE 1-63	90025	11	129B149   239	4261006014	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			12/14/2012 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.04774	-118.44842	This is 63 unit apartment , four story, type 5 , fire  alarm to be defered., 58000 sq feet title 24. and emergency lighting. Located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
959	12041-20000-23570	4942 N VINELAND AVE	91601	4	168B173    75	2421010009	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	12/26/2012 12:00:00 AM	ADDRESS	34.16051	-118.37008	Plan check for energy and emergency lighting. 1527sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
960	10041-10000-06977	515 S FIGUEROA ST 19TH FL	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	04/21/2010 12:00:00 AM		Permit Finaled	09/17/2010 12:00:00 AM	ADDRESS	34.05199	-118.25764	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
961	17041-10000-22123	5320 N FALLBROOK AVE	91367	3	171B097   298	2040030014	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.16681	-118.62307	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
962	14041-10001-35509	800 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM			PC Info Complete	07/02/2015 12:00:00 AM	ADDRESS	34.04484	-118.26453	((7/2/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2.  CHANGES INCLUDE ADDITIONAL SQUARE FOTAGE ADDITONAL LIGHTING FIXTURES AND REVISIONS TO ENERGY CALCS. Installation of canopy lights, connect heaters in restaurant. T24. Total area = 1321 sq. ft. Using 2008 compliance forms, building application submitted March 2014	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
963	15041-10000-40754	1547 W 36TH PL	90018	8	120B193  1362	5041017015	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Expired	01/05/2018 12:00:00 AM	ADDRESS	34.02197	-118.30453	PV1 3.6KW AC roof mounted system with (17) Kyocera KU265 modules and (1) ABB PVI-3.6-OUTD inverters interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
964	12041-10000-19637	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	33.93195	-118.41136	Plan check T24 Energy for lighting in new cooler on the 2nd floor. Permit for new branch circuits and qeuipment for cooler system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
965	15041-10000-00756	851 E 60TH ST	90001	9	105B209    63	6007004012	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	33.98579	-118.25992	Remove HID light fixtures and replace with new LED fixtures in (E) commercial warehouse space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
966	19041-20000-43755	17429 W LAHEY ST	91344	12	210B129   218	2711012005	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.27343	-118.51412	NEW ROOF MOUNTED SOLAR SYSTEM USING AC MODULES AND PV LOAD CENTER. TOTAL SYSTEM SIZE IS 12KWAC/12KWDC/ 10.8KW AC-CEC.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
967	16041-10000-08338	11611 W MAGNOLIA BLVD	91601	2	171B169   359	2348006024	[Q]R4-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.16503	-118.38486	New Pedestrian bridge connecting two (E) build. on site. Install EM light along the pedestrian path. PC for Energy only, total outdoor area 2000 sq.ft.<<CREATE CONNECTION FROM MAIN SCHOOL BUILDING TO NEW PEDESTRIAN BRIDGE ON PERMIT 15020-10000-02507>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
968	19041-20001-21798	241 E LINNIE CL	90291	11	106-5A145 468	4227005018	RW1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM			PC Approved	07/26/2019 12:00:00 AM	ADDRESS	33.9846	-118.46681	Expedite per aplicant request Plan check for PV roof mounted system bettery energy storage system, PV system size: 6.4KW with 20 PV Modules  and 1 inverter(Huawei SUN2000 7.6KW) and battery 9.8KWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
969	12041-10000-28489	1025 N HIGHLAND AVE 7th floor	90038	4	144B185   830	5532028004	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/28/2012 12:00:00 AM			PC Approved	11/28/2012 12:00:00 AM	ADDRESS	34.08969	-118.33884	T.I. on a storage facility located on the 7th floor of a fourteen story building.  This phase 2 of a remodel.   Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
970	18041-20000-34519	4151 W PROSPECT AVE Bldg#25 Rm-127 A/B	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for Title 24 only in existing office space T.I. in room 127 A/B. Total aera: 209 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
971	15041-10000-16525	2263 W COLORADO BLVD	90041	14	162A221    70	5671016025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	34.13961	-118.21567	ALTERATIONS IN A BANK OF AMERICAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
972	14041-10000-19807	948 N ONEONTA DR	90065	1	153A221   201	5475015023	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.11392	-118.21532	Installation of roof mounted solar PV array.  Total system size = 7.6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
973	18041-10000-28064	12772 W ZANJA ST	90066	11	111B153  1204	4236021020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			07/26/2018 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	33.99693	-118.43761	****SEE APPLICATION COMMENTS*****PC FOR POWER AND ENERGY FOR NEW TYPE VA  9  UNIT 4 STORY APARTMENT BUILDING OVER TYPE I SUB-GARAGE WITH ROOF DECK. NEW SERVICE RATED AT 1000A 120/208 3PH. TOTAL AFFECRTED AREA  ***TBD***  22752 SQ.FT (INDOOR+OUTDOOR). B#18010-10000-01784	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
974	13041-10000-32391	1250 S LA CIENEGA BLVD	90035	5	132B173  1178	5087003014	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.05438	-118.37595	INSTALLATION OF NEW ADDRESSABLE FIRE ALARM PANEL WITH AUTO AND MANUAL DETECTION WITH SPRINKLER MONITORING. 38 DEVICES AND 2 PANELS. BUILDING IS FULLY SPRINKLERED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
975	11041-10000-12643	2347 S SEPULVEDA BLVD	90064	5	123B153    19	4322022007	M2-1VL	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM	06/17/2011 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.03702	-118.43558	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
976	18041-10001-18188	20239 W WYNFREED LANE	91326	12	216B113   202	2701048001	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM			PC Approved	05/29/2018 12:00:00 AM	ADDRESS	34.29174	-118.57483	INSTALL A 18.4 KW PV SYSTEM WITH 57 PV MODULES AND A CENTRAL INVERTER.(57) MODULES-SILFAB SLA-M 310(57) OPTIMIZERS-SOLAREDGE P320(1) INVERTER SOLAREDGE SE11400A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
977	15041-10000-39392	1518 W 28TH ST	90007	8	123B197  1576	5054034005	R2-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.02942	-118.29511	PV1 roof mounted installation for a single family home. (1) inverter: 3 Kw. (8) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
978	14041-10000-17746	541 S SPRING ST # 108, 109-& 110	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.04657	-118.2507	NEW RESTAURANT WITHIN AN EXISTING MERCANTILE SPACES, CHANGE OF USE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
979	19041-20000-02461	14540 W ERWIN ST 1-48	91411	6	178-5A151 276	2241013029	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	07/13/2021 12:00:00 AM	ADDRESS	34.18343	-118.45017	NEW FIRE ALARM SYSTEM IN A  48 UNIT APARTMENT COMPLEX. SCOPE INCLUDES NEW FA CONTROL PANEL, 3 POWER SUPPLIES AND 133 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
980	16041-20000-45146	3201 S COLBY AVE	90066	11	120B153  1197	4250018018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.02153	-118.43273	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (37) modules. Standard plan is being used.$33.63 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
981	17041-20000-16929	12023 RICASOLI WAY	91326	12	216B109   359	2701084009	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	PIN	34.29152485	-118.58539213	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.8 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
982	14041-20000-14572	4458 N WESTCHESTER DR	91364	3	166-5A111  38	2174013027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.15172	-118.5836	Roof mounted PV system.  Total system size 17KWdc.Note: Permit fee $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
983	13041-20000-21800	15732 W BLACKHAWK ST	91344	12	204B141   240	2661014015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.25817	-118.47512	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING 24 MODULES. USING TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
984	14041-10000-09235	21810 W NORDHOFF ST	91311	12	195B105     4	2779020052	QMR1-1, QP-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.23524	-118.60337	Remove HID light fixtures and replace with new fluorescent fixtures. Total area 26560 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
985	10041-20000-24238	18425 W BURBANK BLVD #102	91356	3	174B125   370	2160001023	C2-1L, C4-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	ADDRESS	34.17242	-118.53474	Plan check power and energy for medical office TI suite #102	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
986	15041-10001-04296	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN REVIEW OF REN  FILES FOR CHANGES ON SITE DURING THE BRADLEY  RENOVATIONS-ATTACHED SHEET LISTS THE CHANGES AND THE DRAWING PAGE NUMBER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
987	17041-10001-04640	20159 W RINALDI ST S5	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.27528	-118.57287	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding site lighting, replacing exterior lights, and revising title 24. Also changing address per building application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
988	12041-20000-12842	512 E ROSE AVE	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			06/04/2012 12:00:00 AM			PC Approved	06/04/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	T.I. to existing building in retail B.  Install general lighting.  Plan check for energy only.  Note: Permit issued under12041-20000-12844	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
989	18041-30000-07163	2029 S CENTURY PARK EAST 41st Floor-RR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing space men and women restroom on 41st floor. Total area: 410 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
990	19041-10000-41332	14311 W VENTURA BLVD	91423	4	165B153  1093	2265019031	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.15039	-118.44453	NEW FIRE ALARM SYSETM WITH 131 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
991	11041-10000-01630	927 S WOOSTER ST 1-5	90035	5	132B169   172	4333011002	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.00	Electrical	Electrical	Public Safety Only			01/27/2011 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.05996	-118.38266	New fire alarm system for 5 units apprtment building. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
992	15041-20000-37656	925 W 34TH ST 1ST & 2ND-FLOOR	90089	8	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM			PC Info Complete	11/09/2015 12:00:00 AM	PIN	34.02383917	-118.28572873	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (USC WAITING/CORRIDOR AREAS). SCOPE INCLUDES REPLACING LIGHTING IN THE WAITING AND CORRIDOR AREAS. TOTAL AREA IS 2877 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
993	11041-20000-03830	1055 W 7TH ST 5th, 7th-12th floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM			PC Info Complete	04/04/2011 12:00:00 AM	ADDRESS	34.0507	-118.26334	T.I. to restrooms/storage in existing high rise building of 5th floor and 7th thru 12th floors.  Install news branch circuits and lighting fixtures on existing circuits.  Plan check for energy and power.  Plan check electrical system in reference to approved plans under #10041-20000-24915	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
994	13041-10000-29232	12105 W ART ST	91352	6	195B165   482	2634037020	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.2297	-118.39662	PV1, ROOF-MOUNTED SOLAR INSTALLATION INTERCONNECTING WITH EXISTING 200A MAIN SERVICE. XFORMERLESS SYSTEM DONE ON  NON-STANDARD PLAN. SYSTEM SIZE IS 5.886 KW DC AND 6.00 KW AC, WITH 18 MODULES (SUNPOWER; SPR-E20-327) AND 1 INVERTER (POWER-ONE; PVI-6000-OUTD-US)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
995	16041-30000-33768	959 N SEWARD ST 1st FL	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.08878	-118.33338	Plan check for Change of use from office to recording studio. Total area: 6,855 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
996	12041-10000-24875	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	10/27/2021 12:00:00 AM	ADDRESS	33.94571	-118.38857	PLAN CHECK FOR FIRE ALARM SYSTEM. REPLACE EXISTING FACP  AND INITIATION DEVICES. ALL NOTIFICATION & SPEAKERS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
997	11041-10000-24912	1334 S CENTRAL AVE	90021	14	121-5A213   5	5130008042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM	01/12/2012 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.02855	-118.24651	New manufacturing equipment for Coca-Cola.  Next phase of project on permit# 1104-10000-09073.  Full plan check.  <<<Fees for 320' of bus cable need to be added to application>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
998	19041-10000-47361	8431 N MELBA AVE	91304	12	192B093    95	2005014005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.22328	-118.63564	PLAN CHECK FOR PV1 INSTALLATION WHICH INCLUDES AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 36 MODULES (LG320N1K-A5), 1 CENTRAL INVERTER (SE7600H-US), AND 36 OPTIMIZERS (P320). SYSTEM SIZE: 11.52 KW DC; 7.6 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
999	14041-20000-34088	5301 E ALDAMA ST	90042	1	153A225   279	5469024031	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	03/28/2015 12:00:00 AM	ADDRESS	34.11349	-118.20132	PV 1 roof mounted system size: 3.6kW with 1 inverter and 21modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1000	12041-10000-11979	8631 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM			PC Info Complete	09/21/2012 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check power and energy for Suite #240E Cardio Thoracic exam rooms	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1001	18041-20000-17681	11601 W WILSHIRE BLVD STE 440	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing space T.I. office space. Total area: 2381 sq ft.B#18016-10000-13120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1002	11041-10001-20080	1611 S BEVERLY GLEN BLVD 1-6	90024	5	132B157   380	4327005023	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			08/05/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.05941	-118.42528	REVISED SITE PLAN AND SINGLE LINE DIAGRAM TO SHOW UNDERGROUND SERVICE CONDUCTORS FOR FUTURE UNDERGROUND SERVICE INSTEAD OF OVERHEAD NEW 12-UNIT APARTMENT WITH NEW 800A SERVICE.  4-STORY, WITH UNDERGROUND PARKING.  PLAN CHECK FOR POWER AND ENERGY.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1003	10041-20000-22638	12121 W WILSHIRE BLVD #900	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	PIN	34.04391963	-118.46825257	T.I. to a high rise building of 9th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1004	14041-10001-07093	11365 W CHARNOCK ROAD	90066	11	117B157   762	4249029003	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	34.01431	-118.42394	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUST.{{PV1, INSTALL 8.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800-US-ZB-U(34)MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1005	10041-10000-16659	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.10191	-118.28217	Install an Optional Standby 500KW UPS to supply existing sub station #3 located in the basement of the building.  No loads added to the system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1006	13041-10000-34197	380 WORLD WAY Space T45	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	plan check per iNSPECTOR for installation of listed luminaires. PROPOSED 709 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Petrossian).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1007	19041-10001-29981	5200 N LANKERSHIM BLVD 160	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.16511	-118.37448	12-26-2019 Changes to an approved set of plan, Changes include relocate transformer. Plan check only, permit covered under master application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1008	19041-20001-26100	15950 W CHATSWORTH ST	91344	12	207B141   408	2668002017	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.26449	-118.48014	10/3/19Changes to approved set delta 2 only changes to lights and photometrics.<<<T24 PLAN CHECK FOR EXISTING COMMERCIAL CHURCH BUILDING. LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 3815 SF>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1009	15041-10002-22663	3165 W 6TH ST	90020	13	135B197   953	5077003013	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	ADDRESS	34.06383	-118.29074	Supplemental to changes to approved set of plans - changes include relocation of circuits and addition of new lighting in mezzanine area - changes are reflected under delta 7 only Full plan check for an Ihop Restaurant expansion T.I located in a MATHANE ZONE. Scope includes a new 600-Amp  3-phase 4-wire 120/208V service, 6-panels, 7-equipment, 97-circuits and a total of  22,197-SQ feet for T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1010	14041-20000-17243	6621 N FALLBROOK AVE 2ST FLOOR	91307	12	180B097   429	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.19037	-118.62371	T.I. to BuyBuy Baby store .  Install panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1011	17041-20002-30118	13951 W ENADIA WAY	91405	2	183B153   197	2216006008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.2004	-118.43747	[[[10/10/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES ARE CLOUDED. PLANCHECK ONLY.  ADDITION OF 125 AMP SUBPANEL. ]]]]]Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (43) modules, (1) load center, and (2) Tesla Powerwalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1012	14041-10000-07121	906 E 78TH ST	90001	9	099B209   261	6023029019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	33.96836	-118.25833	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN FOR CENTRAL TRANSFORMERLESS INVERTER.  SYSTEM SIZE: 2.5 KW.(10) CANADIAN SOLAR CS6P-250PX(1) POWERONE PVI 3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1013	19041-20000-52893	2309 N BANYAN DR	90049	11	138B133    57	4492007002	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Issued	01/13/2020 12:00:00 AM	ADDRESS	34.0778	-118.50431	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM AND ESS. PV SYSTEM SIZE IS 12.25 KW DC/7.6 KW AC. ESS SIZE IS 6.5KWH. SCOPE OF WORK CONSISTS OF (35) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER,  60A  PV SUB-PANEL, AND A 5 KW AUTO-TRANSFORMER.Fees $86.81 due to California Senate Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1014	15041-10000-43294	12425 W VICTORY BLVD	91606	2	180B165   708	2333003008	[T]RAS4-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	05/11/2017 12:00:00 AM		Issued	05/11/2017 12:00:00 AM	ADDRESS	34.18684	-118.40388	FULL PC TO A NEW 80 UNIT HOTEL AND PARKING GARAGE 4 STORY W/BASEMENT. 2500 AMP SERVICE. SECOND AND THIRD FLOOR CONTAIN TYPICAL PANELS. TOTAL SQ. FT. 53324 FOR INDOOR AND OUTDOOR LIGHTING. .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1015	16041-20001-08781	6935 N TOBIAS AVE	91405	6	183B149   479	2219013006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.19669	-118.45213	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.35 KW(50) SUN POWER SPR-327 MODULES(1)  ABB PVI-5000(2)  ABB PVI-6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1016	11041-20000-04476	1320 S MAIN ST	90015	9	124-5A207 181	5133011008	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.03563	-118.26069	"New 800A service, panels, and branch circuits.  Plan check for energy and power.Note:  ""COMPLY WITH DEPARTMENT ORDER effective date09/18/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1017	19041-20000-35364	7650 N RESEDA BLVD	91335	12	186B125    45	2119001065	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			Reviewed by Supervisor	09/17/2019 12:00:00 AM	ADDRESS	34.2098	-118.53586	Plan check for PV roof mounted system, PV system size: 12.96KW with 32 PV Modules and 1 inverter(10KW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1018	17041-10000-18476	5520 N TOPEKA DR	91356	3	174B121   523	2161001045	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.17174	-118.54642	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1019	15041-10001-01067	12542 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.97819	-118.41198	(3/3/2015) CHANGES TO AN APPROVED SET OF PLANS.  CHANGE FROM UNDERGROUND SERVICE TO OVERHEAD SERVICE.  DELTA ONE REFLECT THE CHANGES DONE ON THE PLANS.Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps. Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1020	18041-20000-34311	13756 W ROSCOE BLVD	91402	6	192B153   773	2213016003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.2215	-118.43309	Plan check for Title 24 only in existing space, T.I. Ice Cream Shop. Total area: 584 sq ft. B#18016-10000-09826	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1021	15041-20003-01844	416 W 8TH ST	90014	14	127-5A209  58	5144018030	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM			PC Approved	01/12/2017 12:00:00 AM	ADDRESS	34.04471	-118.25646	Revisions to approved set.  Modified routing of supply conductors from emergency generator to fire pump controller.  Delta-17 revisions only.  Affected sheets - E114 and E900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1022	11041-20000-09288	127 S SAN VICENTE BLVD Bulletin-36.1 CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	Revision plan check only Bulletin # 36.1 CS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1023	11041-10000-11827	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	Ti in a atorage area. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1024	14041-10002-35665	921 W VENICE BLVD	90015	1	126A203   113	5135030011	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.04013	-118.27572	FULL PC. ADDTIONAL OF 4 FLOOR TO ORIGIONAL DESIGN FOR 3 STORY BUILDING. UPGRADE SERVICE TO 8OOAMP NEW 4 FLOOR POWER AND LIGHTING PROVIDED ON PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1025	16041-20000-25564	3481 W OLYMPIC BLVD	90019	4	129B189   213	5081025020	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM			PC Info Complete	07/20/2016 12:00:00 AM	ADDRESS	34.05276	-118.31427	REVISIONS TO AN APPOVED SET OF PLANS.  REVISIONS INCLUDE ADDITION OF 200 AMP PANEL AND RELOCATE EXSITNG CIRCUITS INTO PANEL F.  REVISIONS NOTED DELTA 1. PLAN CHECK FOR POWER ONLY.  MASTER APPLICATION UNDER 15041-10000-03570.Plan check for power and energy (7 Eleven) 800Amp service with 5 panels. Total area: 2684SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1026	19041-10000-02540	4343 N LANKERSHIM BLVD	91602	4	165B177   566	2423019075	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	03/23/2021 12:00:00 AM	ADDRESS	34.14909	-118.36531	FULL PLAN CHECK FOR AN INTERIOR TENANT IMPROVEMENT OF AN EXISTING MEDICAL OFFICE BUILDING. SCOPE INCLUDES NEW GENERATOR, NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 11,475-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1027	13041-10000-00635	5450 W PICO BLVD	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.04862	-118.35714	T.I OF ONE OFFICE BEING SPLIT INTO TWO SMALLER OFFICES. TITLE 24 ONLY. AND EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1028	14041-20000-06248	8533 N CASABA AVE	91306	3	192B113   123	2781010012	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.22552	-118.5765	PV1 ROOFTOP MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1029	15041-20000-43772	6014 N PASEO LA VISTA	91367	3	177B085   239	2032030012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	02/02/2016 12:00:00 AM		Refund in Progress	01/24/2017 12:00:00 AM	ADDRESS	34.18183	-118.66704	FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 17.49KWdc/15.2KWac.(66)KYOCERA #KU2656ZPA(2)INVERTER-FRONIUS #PRIMO 7.6(1)125A SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1030	15041-10000-34376	200 S LOS ANGELES ST STE A1	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.05007	-118.2433	T-24. TI to an existing commercial building (Angelo's Barbershop). (1) New panel of 150 A. PC for energy only. Total Sq Ft = 837	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1031	13041-10000-12539	236 S LOS ANGELES ST	90012	9	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Closed	03/18/2015 12:00:00 AM	ADDRESS	34.04922	-118.24386	FIRE ALARM IN AN APARTMENT COMPLEX CONSISTING OF 785 TOTAL DEVICES AND A SINGLE FIRE ALARM CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1032	14041-10000-17198	335 W 7TH ST	90731	15	015B201   199	7455011028	CM-2-CDO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	33.7377	-118.28444	REPLANCHECK FOR T24 ENERGY PER APPLICANTS REQUEST. ORGINAL PC # 14041-10000-12124.Plan check for T24 energy only. 1 story and emergency lights installed. Less than 400A per applicant.  INT T.I. & STOREFRONT REMODEL - CHANGE OF USE FROM RETAIL TO RESTAURANT (1,929SF), NEW RESTROOMS AND SOFFIT CONSTRUCTION PER PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1033	17041-10000-24339	1809 W 50TH ST	90062	8	111B193  1062	5015006021	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	33.99809	-118.31173	PC FOR ROOF MOUNTED PV SYSTEM ON SFD. TOTAL SYSTEM SIZE 3.0KW/ACINCLUDING 10 MODULES WITH 10 POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1034	14041-10000-12103	2516-2518 1/2 W SUNSET BLVD	90026	13	141A205   298	5402014002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.07961	-118.26967	PLAN CHECK FOR ENERGY ONLY FOR TENANT LEASE SPACES. TOTAL LOAD DOES NOT EXCEED 400AMPS. ONE OWNER, ONE APPLICATION, ONE PERMIT FOR THE FOLLOWING ADDRESS RANGE: 2516, 2516 1/2, 2518, 2518 1/2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1035	19041-10000-02165	5025 E HUNTINGTON DR NORTH	90032	14	144A235   179	5307012025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.08864	-118.17311	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1036	15041-20000-06350	6320 N TOPANGA CANYON BLVD G-1690	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title 24 (energy).  Total area = 6,575 sq. ft.T.I. to (new) Wokcano restaraunt.  First time tenant.  3 new panels, 1 1125 KVA transformer, and lighting + equipment loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1037	14041-20000-00776	3809 N ROCK HAMPTON DR	91356	3	162B125   241	2184057010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.14001	-118.53382	PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS FOR 1 INVERTER. TOTAL SYSTEM SIZE 6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1038	16041-10000-37247	1990 S BUNDY DR #395	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	34.03419	-118.45559	PC FOR ENERGY ONLY(T24). HIGH RISE BUILDING. 3RD FLOOR. T.I COMMERCIAL . TOTAL ARAEA 3900 SQ FT. PERMIT HAS BEEN PULLED UNDER 16041-10000-36935.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1039	16041-10000-45793	7157 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES  Adding new lighting, medium voltage power, and emergency power to LAX MSC utility equipment room Total area: 5285. b#16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1040	13041-10001-00247	1751 N LAS PALMAS AVE	90028	13	150A185   354	5547002030	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			09/19/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.10334	-118.3364	09/19/2017 Changes to an approved set of plans, changes include location of main switchboard, single line diagram and voltage class to 3p,120/240.  This is plan check only, permit is included under master #13041-10000-00247_____________ T24 AND POWER FOR NEW 5 STORY APARTMENT BUILDING.  24 UNITS TOTAL.fire alarm plans approved under permit #130411000015410	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1041	12041-10000-01368	2252 N TRACY TER	90027	4	148-5A205 160	5433017006	C1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2012 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Expired	03/04/2014 12:00:00 AM	ADDRESS	34.10205	-118.2735	New 5.04kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1042	13041-10000-23576	22075 W RAYEN ST	91304	12	195B101   140	2010006018	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.2314	-118.60862	][][APPLICATION # IS ASSOCIATED WITH BOTH PLAN CHECK, AND PERMIT][][][PV1, INSTALLING ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE AT 8.085 KW , CENTRAL INVERTER IN A 2-STORY HOUSE. (33) MODULES: TRINA SOLAR #TSM-245PC05/PA05.18(1) INVERTER: FRONIUS # IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1043	14041-20000-01578	20619 W HORACE ST	91311	12	207B109    30	2707028022	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.26737	-118.58256	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.((((THIS IS AN ADDITION TO AN EXISTING PV SYSTEM. INVERTER TO REMAIN. THIS IS ADDITION OF 4 SOLAR MODULES ON THE DC SIDE OF THE SYSTEM))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1044	11041-20002-04235	2614 W 7TH ST	90057	1	133-5A201 297		C2-2, R4-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	Plan check for revision to approved plans. Delta 4 revision from 70.56KW to 68.04KW Photovoltaic system. Revisions consist of replacing (6) 10KW inverters to (9) 6KW inverters, reduce number of modules, subpanel, and PV layout change.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1045	15041-20000-09874	12827 W VICTORY BLVD	91606	2	180B161  1043	2325032012	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.18684	-118.41269	Title 24 plan check only.  Total area = 208,125 sq. ft.Installation of new canopy fixtures on first floor of two story parking garage and wall packs on exterior of garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1046	18041-20000-11004	7900 N BALBOA BLVD Bldg ' X '	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.21347	-118.50092	New aircraft hangar supplied from adjacent hangars.  Plan check for power and energy.  Building permit issued under 17010-20000-03144	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1047	13041-10000-24746	5403 W SUNSET BLVD	90027	13	147A193    61	5544022054	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.09828	-118.30729	Change of use from retail to Veternian clinic.  Newly connected load less than 400A, title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1048	11041-10003-08260	540 S SANTA FE AVE	90013	14	126A217   221	5164004002	M3-1, PF-1XL	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.04042	-118.23057	ADDITION OF NEW CIRCUITS ON PANEL LB4(((((((((CHANGE FEEDERS TO ALUMINUM AND TENANT IMPROVEMENT ( FIRST TIME TENANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1049	14041-20000-08061	2800 N GLENDALE BLVD	90039	4	150A207    24	5438019017	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			Reviewed by Supervisor	04/22/2014 12:00:00 AM	ADDRESS	34.10721	-118.26305	PLANCHECK FOR POWER AND ENERGY. Core and shell for a new 3 story office building. PREVIOUSLY PLANCHECKED UNDER 09041-10000-10638. REPLANCHECK REQUIRED DUE TO EXPIRATION OF PLANCHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1050	18041-10000-42031	3436 W SAN FERNANDO ROAD	90065	13	153B209    35	5458003017	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.11978	-118.25104	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1051	10041-20000-25725	1050 W PACIFIC COAST HWY 1st floor	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			PC Info Complete	12/28/2010 12:00:00 AM	ADDRESS	33.79072	-118.29449	Per applicant, electrical plan check for new receptacles in room WADS 1702 as shown on plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1052	13041-10000-00294	13606 W ROSCOE BLVD	91402	6	192B157   678	2213021013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			01/04/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.22145	-118.42935	A new building (7-Elevent).  Add a new 600A subpanel to feed the downstream panels, and branch circuits. Plan check for power and energy.  Note: All existing loads obtain from previously approved plan 12041-20000-29553.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1053	19041-10000-23318	1404 W 6TH ST	90017	1	132A205   165	5142028019	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.0559	-118.26781	T-24 PLAN CHECK FOR A CHANGE OF USE TI FROM RETAIL TO ICECREAM PARLOR. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1475SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1054	14041-20001-29472	5209 N BUFFALO AVE	91423	4	171B157   607	2344016012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	PIN	34.1652068	-118.4304093	Fee for expedite only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1055	12041-10000-29345	5316 N LUBAO AVE	91364	3	171B113   150	2164004031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.16655	-118.56675	PV1 15.042KW ROOF-MOUNT SUNPOWER. POSITIVE GROUND 2 STORY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1056	16041-10003-27658	405 S MATEO ST	90013	14	127-5A217  62	5163018006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.04184	-118.23305	02/16/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 12. Chnage have been made to the lighting floor plan of the lobby. All changes have been reflected onto the Title 24 compliance forms. *****Previous Work Description*****Changes to approved set (partial single line diagram is revised, T24 revised due to architectural change), all changes are clouded.<<PC FOR POWER AND ENERGY. CORE&SHELL RENOVATION OF EXISTING BLDGS, NO TENANT IMPROVEMENT IS INCLUDED AS PART OF SCOPE. SERVICE 4000A, 480/277 3 PHASE AND 4W. TOTAL AREA 5919 SQ FT.B#  16016-10000-17710>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1057	16041-20000-30888	13974 N TUCKER AVE	91342	7	231B161   147	2582025031	RE11-1-H	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.32597	-118.40968	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1058	16041-20001-29553	5757 N AGNES AVE	91607	2	174B165   282	2340027041	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.1753	-118.39561	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (25) modules. Standard plan is being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1059	16041-30000-17323	4014 S MUIRFIELD ROAD	90008	10	114B181     8	5032012005	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01277	-118.34586	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1060	14041-10000-25503	3421 S SYCAMORE AVE	90016	10	120B177   822	5047005015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.02464	-118.35733	Installation of roof mounted solar PV array. Total system size = 5KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1061	13041-10000-29369	5200 W CENTURY BLVD	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	03/21/2014 12:00:00 AM		Issued	03/21/2014 12:00:00 AM	ADDRESS	33.94516	-118.37049	PLAN CHECK FOR POWER. TENANT IMPROVEMENT. ( MECHANICAL UPGRADES) PROVIDE ELECTRICAL POWER SUPPLY TO NEWLY REPLACED CHILLERS, COOLING TOWER PUMPS AND AIR COMPRESSERS. NEW CONNECTED LOAD 1065.5 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1062	19041-20000-36374	1303 N EL PASO DR	90065	1	154-5A221 104	5472003059	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	PIN	34.11869179	-118.21996508	PV1. INSTALL 4.8 KW DC PV SYSTEM. (15) MODULES AND (P400) OPTIMIZERS WITH (1) INVERTER (SE3800).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1063	15041-10000-00986	12150 W MILLENNIUM	90094	11	102B161  1214	4211010111	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	33.97946	-118.40662	PC FOR POWER AND ENERGY. FIRST TIME TENANT FROM PARKING TO BUSINESS OFFICE(LAT 34 MARKETING OFFICE) . TOTAL AREA   2343 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1064	17041-10000-12448	1106 N CORNWELL ST	90033	14	132A225   232	5202007026	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.05576	-118.20478	PC FOR ENERGY. T.I. (OUTDOR/INDOOR) CONNECTED LOAD > 400. NEW 600A PANEL. EXISTIG 800A PANELBOARD. TOTAL AREA 17755 SQ FT. B # 17016-10000-09608	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1065	12041-10000-10928	1460 W 27TH ST	90007	8	123B197  1350	5054032011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Apartment			05/11/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Expired	10/16/2014 12:00:00 AM	ADDRESS	34.03028	-118.29351	Plan check for 33KW roof mounted photovoltaic system for apartment building. Site located in Methane Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1066	13041-10000-01501	1536 N HIGHLAND AVE	90028	13	147A185    15	5547020046	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM			PC Approved	01/18/2013 12:00:00 AM	ADDRESS	34.09911	-118.33847	PERMIT TO BE ISSUED AT PLAN CHECK COUNTER.existing turtoring center for children. T24 FOR NEW LIGHTING PLAN. MANY RELOCATED LGIHTS AND NEW LOADS. TOTAL OF 5460 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1067	14041-10000-04010	128 S LA BREA AVE	90036	5	138B181   988	5513018007	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.07266	-118.34383	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1068	14041-10001-14508	1825 N BRONSON AVE	90028	13	150A191   280	5586027006	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.10425	-118.31823	(148) NEW DEVICES.  ONE NEW PANEL / PERMIT WAS PULLED UNDER 14041-10000-14508. PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1069	11041-10001-04935	8500 W BEVERLY BLVD # 684	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	Moddification to a set of exisiting approved set of plans.  Changing the quantities of the lighting fixtures that wew being installed.  Plan check is for energy only.  <<<<<TENANT IMPROVEMENT IN RETAIL STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTnote that previous plan chk  and permit was on 11041-10000-01376 ; new lay out of the space and revised lighting system>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1070	13041-10000-28792	5819 N CAPISTRANO AVE	91367	3	174B101    38	2040042003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	34.17675	-118.617	PV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL INVERTER STANDARD PLAN. SYSTEM SIZE: 8.25 kW DC.(33) TRINA SOLAR # TSM-250(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1071	16041-20001-21210	10345 W DIAMOND ST LOT 9	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1072	16041-20000-40729	17526 W INDEX ST	91344	12	210B129    73	2711007029	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.27562	-118.51632	pv1install ground mount system 3.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1073	16041-10001-25757	4945 N EAGLE ROCK BLVD #B	90041	14	162A221   398	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM			PC Approved	09/06/2016 12:00:00 AM	ADDRESS	34.13606	-118.21531	change in size of AC units. restamping plans. no other changes	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1074	15041-20000-11410	6638 N LANKERSHIM BLVD	91606	2	180B169   412	2320027005	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	ADDRESS	34.19161	-118.38758	Plan check for office building T-24 only. Indoor and outdoor lights. Total area:  7251 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1075	19041-10001-02353	5957 N LAUREL CANYON BLVD	91607	2	177B165   793	2340004048	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	34.17887	-118.39677	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS FOR A RESTAURANT. TOTAL AFFECTED AREA IS 840 SQ. FT. Note: Permit has been paid under PCIS 19041-90000-02353	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1076	18041-10003-07714	3016 S SOMERSET DR	90016	10	120B185   529	5050030040	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.02706	-118.33724	Supplemental plan check only to an approved plan, resize the load center from 200A to 125A, load has been verified per load calculation on the plan. Permit is covered under master# 18041-10000-07714((PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. CONISIT OF 14 MODULES(#SC325) AND A CENTRAL INVERTER (DELTA SOLIVIA 3.8) . SYSTEM SIZE IS 3.8KWac AND 4.55KWdc.SCOPE INCLUDES ONE NEW LOAD CENTER (200A each).))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1077	18041-10000-02653	7681 W WILLOW GLEN ROAD	90046	4	153B173    75	5569001003	RE11-1	South Valley	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM			PC Info Complete	02/27/2018 12:00:00 AM	ADDRESS	34.11872	-118.36855	New 8,600 Sqr Ft SFD with 600 amp service,  Building permit is issued under combined 16010-20000-00614.  Permit for the scope under combo permit above.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1078	17041-10001-00130	1231 E 47TH ST	90011	9	112-5A211 281	5107010012	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.00125	-118.25344	PC FOR A NEW SOLAR PV SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.30KWdc / 4.30KWac.(20)MODULES-HANWAH Q. CELL 265WATTS(20)MICROINVERTERS- ENPHASE M215Permit is paid under PCIS#17041-90000-00130	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1079	11041-10000-18263	6039 N DE SOTO AVE	91367	3	177B105    63	2149005032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM	08/26/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	34.18005	-118.5908	NEW FIRE ALARM FOR EXISTING COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1080	14041-20000-25100	11106 N EL DORADO AVE	91331	7	210B157   340	2616030038	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.27176	-118.43189	INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.0KW INTERCONNECTED WITH MSP.(18) HYUNDAI HEAVY INDUSTRIES INDUSTRIES M-250MG MODULES(18) ENPHASE M-215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1081	18041-20000-23478	15171 W KADOTA ST	91342	7	228B145   826	2502027087	(Q)RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.31987	-118.46419	Plan check for PV roof mounted, system size: 10.4kWdc/9.71kWac-CEC with 32 modules and 2 inverters(5.2KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1082	10041-20002-03918	3327 E SABINA ST Bldg C	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	PLAN CHECK TO REVISION TO APPROVED PLANS. CHANGES TO T24 ENERGY, LIGHTING, AND NEW CKTS ADDED. NEW COMMUNITY CENTER FOR NEW APARTMENT BUILDINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1083	18041-20000-08574	149 1/4 E 78TH ST	90003	9	099B205   401	6022007029	R1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Issued	03/08/2018 12:00:00 AM	PIN	33.96904218	-118.27218861	pv2install roof mounted pv system sized 2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1084	17041-10000-23545	300 WORLD WAY T338	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	SMALL RETAIL LEASESPACE INSTALLING SHELVING WITH MILLWORK LIGHTING. T24 PLAN CHECK WILL BE FOR TENANT LEASE SPACE SQUARE FOOTAGE ONLY. T24 SHALL INCLUDE LIGHITNG INSTALLED BY TENANT AND ACCOUNT FOR GENERAL LIGHTING FALLING INSIDE LEASE SPACE SQUARE FOOTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1085	19041-20000-02497	400 S HOPE ST #210	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.05199	-118.25366	TITLE 24 ONLY PLAN CHECK FOR A TENANT IMPROVEMENT TO AN EXISTING OFFICE SUITE IN A HIGH RISE. SUITE #210.SCOPE INCLUDES 2 NEW PANEL (125A AND 225A), LIGHTING AND RECEPTACLES. TOTAL CONNECTED LOAD <400AB#19016-10000-01320	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1086	18041-30000-29198	2029 S CENTURY PARK EAST 1210	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Energy plan check for an office T.I located in 12th floor of a high rise building. Scope includes new lighting and equipment with a total area of 1783-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1087	19041-20000-15062	660 S FIGUEROA ST Ste 700	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.04953	-118.25947	7th floor office TI in (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1088	16041-20000-34801	9310 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.23949	-118.53589	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR RESTAURANT. 2584 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1089	13041-20001-35784	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	33.97749	-118.41246	Changes from previously core/shell plans.  Changes include additional transformers, subpanels, branch circuits, and lighting.  All changes indicate by DELTA-16 on the plans.  Note: Title 24 forms will be submitted by the applicant before the plans get assign.  Approved Core/Shell plans submitted for reference only.*****Previous Job Description*****POWER AND ENERGY FOR FIRST TWO FLOORS OF NEW BLDG. CORE AND SHELL. 2500AMP SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1090	10041-20000-16376	6525 W SUNSET BLVD	90028	13	147A187   106	5547017026	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	06/09/2011 12:00:00 AM	ADDRESS	34.09815	-118.33187	PLAN CHECK TO REPLACE (E) GENERATOR. ORIGINAL PLAN APPLICATION #07041-20000-23418 EXPIRED. WITH THE SAME SIZE NO CHANGES.  NO WORK IN BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1091	19041-10000-46632	6025 N FAIR AVE	91606	2	177B173   998	2337006005	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.18032	-118.3748	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 11.84KWdc (11.4KWac) USING 37 REC320, HUAWEI SUN2000-375W-USP0 MODULES & HUAWEI  11.4KTL INVERTER.CONNECTED TO A 225 AMP NEW SERVICE. (NEW SERVICE UNDER SEPARATE PERMIT)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1092	11041-10000-24650	512 E ROSE AVE	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	1st time tenant, restaurant, in a new low-rise commercial building.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1093	18041-10000-27233	12660 W BRANFORD ST	91331	6	198B161    10	2629002007	QMR1-1-G-CUGU, R1-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.24337	-118.40952	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1094	13041-20001-23733	5858 W ABERNATHY DR	90045	11	099B169   101	4105006013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/07/2013 12:00:00 AM	ADDRESS	33.97081	-118.38396	((EXPEDITE FEES))PV1 TRANSFOMERLESS SYSTEM. 27 MODULES AND 2 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1095	17041-10000-42702	3894 S CRENSHAW BLVD	90008	10	117B185   991	5033003001	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	34.01481	-118.33473	REPLACE OUTDOOR HID LUMINARIES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1096	18041-20000-38403	9524 N SHOSHONE AVE	91325	12	201B129   410	2755009011	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.24414	-118.5176	pv1install roof mounted pv system sized 10.3KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1097	17041-10001-44209	957 W 88TH ST	90044	8	096A199   108	6038010902	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			08/29/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	ADDRESS	33.95803	-118.29064	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGES TO THE AIC RATING OF THE RESIDENTIAL SWITCHBOARD. ALL CHANGES ARE CLOUDED UNDER DELTA 3. DWP LETTER PROVIDED. ORGINAL PERMIT PULLED UNDER 17041-10000-44209((NEW 4 STORY, 41 UNIT APARTMENT BUILDING. SCOPE INCLUDES ADDING A NEW 1600A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD. TOTAL AFFECTED AREA IS 32271 SQ. FT. B#17010-10000-02542	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1098	19041-10000-25106	8600 N HAZELTINE AVE	91402	6	195B153  1016	2638015900	OS-1XL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.22674	-118.44129	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1099	19041-10000-47649	1545 W WILSHIRE BLVD 710	90017	1	132A205   545	5142027036	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.05543	-118.26977	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING SPACE. TOTAL AFFECTED AREA IS 1280 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1100	10041-20002-25689	4338 N LANKERSHIM BLVD	91602	4	165B177   571	2423016108	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Info Complete	06/10/2013 12:00:00 AM	ADDRESS	34.14903	-118.36479	"Plan check for Delta 1 and Delta 3 changes only. Plans have only been checked within printed (not handwritten) clouds. All other changes have been ignored.""COMPLY WITH DEPARTMENT ORDER effective date01/21/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""      Modification to previously approved drawings.  New panels, loads, lighting.      <<<<NEW CONSTRUCTION OF A  (3) LEVELS SHOWROOM, VEHICLE SERVICE FACILITY, PARTS STORAGE AND OFFICES BUIDING WITH ROOF TOP PARKING DECK;>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1101	15041-10003-36116	7326 N VANALDEN AVE	91335	3	186B121   819	2104026001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.20382	-118.54902	02/11/16Changes to an approved set of plans. Changes include rearranging the PV modules on the roof/site plan. (((((PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE: 9KW. (29) MODLUES AND (3) INVERTERS. (29) SUNPOWER SPR-327-NE-WHT-D(3) SMA AMERICA SB3000TL-US-22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1102	17041-20001-41503	1812 S ROXBURY DR	90035	5	129B165   711	4307013027	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.04821	-118.40115	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19.80 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1103	15041-20000-30141	10201 W PICO BLVD Bldg 32	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Issued	03/02/2016 12:00:00 AM	PIN	34.05182951	-118.41257696	$0 permit fee is due to Senate Bill SB-1222.  Installation of new commercial roof mounted solar PV array.  Total system size = 56 kWac.  Two inverter system with 208 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1104	17041-20001-13281	6330 W SAN VICENTE BLVD 310	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.06116	-118.36804	08/31/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes include the use of unit equipment for the EM lighting.*****Previous Work Description*****PC FOR POWER AND ENERGY. T.I TO AN EXISTING MEDICALOFFICE. CONNECTED LOA < 400 AMP. TOTAL AREA 1894 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1105	16041-20000-31911	14863 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29527	-118.45532	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1106	16041-10000-09750	6235 S VAN NESS AVE	90047	8	105B189  1250	4007022020	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	33.9823	-118.31783	PV1, rooftop solar installation. 3.71kW system.   (14) CS6P-265P      (1) PVI-3.0-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1107	14041-20000-22487	2474 S LOUELLA AVE	90291	11	108B149   352	4236008029	R1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	33.99454	-118.44671	Standard plan, 3.2KW PV1 roof-mounted system including : (15) Enphase M215  microinverters and Solar World Sunmodule 275W modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1108	18041-20000-16805	4950 N WHITE OAK AVE	91316	5	168B129   766	2290010023	(T)RS-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.16081	-118.51841	Plan check for PV roof mounted system, system size: 10kW with 50 modules and 1 inverter(10kW) connected to MSP.Fees $ 38.85 dues to Senate Bill	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1109	17041-10001-33864	24904 S PRESIDENT AVE	90710	15	039B193   667	7439026005	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	33.79859	-118.30398	expedite feees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1110	15041-20000-43228	7412 N ETIWANDA AVE	91335	3	186B125   632	2119012002	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.20523	-118.53155	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (27)MODULES-KYOCERA #KU2656ZPA(1)INVERTER- FRONIUS #PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1111	15041-10000-16332	899 S FRANCISCO ST	90017	14	129A207   180	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Public Safety Only			05/28/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.04731	-118.2643	NEW FIRE WARNING SYSTEM FOR THE NEW METROPOLIS HOTEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1112	17041-20000-36736	9841 N AIRPORT BLVD SUITE 414	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 2242 SQFT. SUITE 414.permit pulled under : 17041-70000-21514	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1113	18041-20001-38136	8326 W BLACKBURN AVE	90048	5	138B173  1015	5511034031	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.07168	-118.37111	SUPPLEMENTAL, PLAN CHECK ONLY, Revisions to approved plans.  Changes to distribution equipment locations to accommodate DWP service changes.  Service changed from overhead to underground, increase in utility available fault current.  (((1200A 240/120V 3ph-4w service, distribution, power, and lighting for new building.  Associated building permit under 15010-10000-04219.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1114	11041-20000-07960	1880 CENTURY PARK EAST #711	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	07/20/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	T.I.  EXISTING OFFICE SPACE IN A HIGH RISE BUILDING.  REPLACING LIGHT FIXTURES.  TITLE 24 PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1115	12041-10000-10218	540 S SANTA FE AVE	90013	14	126A217   221	5164004002	M3-1, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM			PC Approved	05/10/2012 12:00:00 AM	ADDRESS	34.04042	-118.23057	two story office bldg, permit already pulled, title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1116	14041-20001-09234	9803 W CRAIGMITCHELL LANE	91040	7	207B181   262	2549024027	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.26023	-118.34493	Expedited plan check per applicant request.  PV1.  Install 4.5 kW roof-mounted PV system.  18 modules: ET Solar ET-P660250BB.  Transformerless inverter: PowerOne PVI--3.8-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1117	19041-20000-53346	6570 S NORMANDIE AVE	90044	8	102B197   171	6014009028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	04/14/2021 12:00:00 AM		Permit Closed	05/14/2024 12:00:00 AM	ADDRESS	33.97929	-118.3001	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1118	15041-20003-34603	10340-10378 N SEPULVEDA BLVD	91345	7	204B145   201	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.2586	-118.46705	"7/11/17changes to an approved set of plans.  reduction in panel 3EV.   changes clouded EV.  this is plan check only.6.27.2017 - Plan check for modifications to approved set. Changing feeders from copper to aluminum + delta J clouded changes ONLY. ""BLDG 3"".=======PC FOR POWER AND ENERGY.  NEW 3500A SERVICE. CHANGE OF USE FROM COMMERCIAL TO RESTURANT. PART OF THE JOB IS FOR SHELL. CAHSE BANK AS EXISTIN REMAINS. TOTAL AREA 3760 SQ FT(OUTDOOR LIGHTING) PLUS 696 SQ FT(INDOOR).B# 15018-10000-21181."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1119	10041-10001-25429	1231 S LA BREA AVE	90019	10	129B181   217	5084028053	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	34.05245	-118.34419	CHANGES TO PERMITTED SET OF PLANS-CHANGES TO PARKING LOT AND INTERIOR LUMINAIRES;REVISED TITLE 24 REPORTS; CHANGES ARE BUBBLED ON THE PLANSDemolished existing McDonald's restuarant and construct new McDonald's restuarant.  Install new switchboard, panels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1120	11041-10001-13096	700 S BROADWAY # 216	90014	14	127-5A211  64	5144015053	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	07/08/2011 12:00:00 AM	ADDRESS	34.04492	-118.25338	Modification to an approved set of plans. Inspector requested the changes to reflect changes out in the field.  Plan check was for energy only.  <<<<<<T24 and emergency lighting plan check for subdivided retail space where an existing retail space is divided  to create a  new exit corridor for the building.  Existing 11041-10000-13096.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1121	15041-10000-03874	8129 S ZITOLA TER	90293	11	096B153   306	4115006024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	33.96077	-118.44426	PV1 9.1kKW DC/ 7.68KW AC roof-mounted system with (35) Rec Solar Rec260PE modules, and (2) ABB PVI-3.6-OUTD inverters interconnecting through a load center.Customer submits plan due to plan cannot be submited online.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1122	14041-10001-24958	14119 W BURTON ST	91402	6	192B153   869	2212020017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.22077	-118.44064	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<,PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1123	15041-10000-36815	7118 N AMIGO AVE	91335	3	183B121   265	2126006016	(T)(Q)RAS3-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.1999	-118.53846	NEW FIRE ALARM PANEL TO A 20 UNIT APARTMENT. 1 NEW FIRE ALARM PANEL AND 68 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1124	14041-10000-03443	7307 N FIGUEROA ST #103	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.13662	-118.18837	"PLANCHECK FOR T24 ENERGY ENERGY. CHANGE OF USE FROM REATIL TO RESTAURANT.  2916 SQFT, EMERGENCY LIGHTING.""COMPLY WITH DEPARTMENT ORDER effective date 07/09/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""BUILDING P#14016-10000-02301."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1125	12041-20000-26116	13079 W CHANDLER BLVD	91401	4	171B161    87	2345012007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.16873	-118.41784	T.I. to a Temple.  Full plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1126	19041-10000-44424	10615 N CEDROS AVE	91345	7	207B149   582	2648005016	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.26303	-118.4539	PC FOR PV-1 SYSTEM. SYSTEM SIZE 5.89KWdc/5KEac. 19 MODULES (S-ENERGY) WITH 19 SOLAR EDGE P320 OPTIMIZERS, (1)SE5000H-US SOLAR EDGE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1127	13041-10000-36249	801 S FIGUEROA ST 19TH FLOOR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.04789	-118.26153	PLANCHECK FOR T24 ENERGY ONLY. NO CHANGE IN OCCUPANCY. OFFICES. HIGH RISE. 19TH FLOOR. 4814 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1128	15041-20000-29712	12233 W OLYMPIC BLVD	90025	11	123B149   494	4259019006	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	PIN	34.03260477	-118.45671268	Plan check for power and lighting. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes the installation of (2) 600-amp rated distribution boards, (14) panel boards, and associated loads. Service is existing. Total indoor lighting area = 22,451 sq. ft.Note: Building plan check has been filed under application number 15016-10000-19313	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1129	16041-10000-24207	21255 W BURBANK BLVD #150	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/11/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.17432	-118.59446	TI to an (E) office space approx. 13,098 sq. ft. Total load < 400A. Plan check for T-24 only. Install new lights and controlled receptacles. B# 16016-20000-15010	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1130	13041-10000-09114	1301 S BROCKTON AVE 1-49	90025	11	126B145   184	4263023092	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Public Safety Only			04/09/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.04404	-118.46381	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING FOR A 49 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1131	14041-20000-30776	1400 S GRAND AVE suite 805,-812	90015	14	124-5A207  58	5134020023	C2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.03697	-118.26528	Plan check for power and energy. TI to existing USC medical office (merging two suites) on 8th floor of existing high rise building. New lighting and wiring (incl. in exam areas). 540sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1132	14041-20000-16598	13133 W BRACKEN ST	91331	6	198B161   313	2625008011	RS-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.23831	-118.41898	4.3KW PV1 roof-mounted system with (20) Sunmodule SW270 modules and Enphase M215 microinverters interconnecting through a load center subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1133	18041-10000-22313	20200 S WESTERN AVE	90501	15	054B193   700	7351021038	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Issued	06/15/2018 12:00:00 AM	ADDRESS	33.84769	-118.30905	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1134	19041-10000-20297	7077 W WILLOUGHBY AVE SUITE 101	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/09/2022 12:00:00 AM	ADDRESS	34.08719	-118.34375	PC (POWER AND ENERGY) FOR GYM, FIRST TENANT CORE AND SHELL. MIX USE BUILDING WITH  4000A SERVICE. PROJECT SCOPE IS 1ST FLOOR. AREA OF SCOPE 14,616SF.BUILDING #: 16010 - 10013-03070	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1135	13041-10000-02746	4455 N LANKERSHIM BLVD	91602	4	165B173   141	2423009050	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	34.15185	-118.36703	TI OF EXISTING BANK. 4 ALTERED OFFICE SPACES. T24 ONLY. TOTAL AREA  OF 300 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1136	15041-10000-04542	225 S 26TH ST SPACE#35	90049	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	PIN	34.04786183	-118.49061927	PC FOR ENERGY T24 ONLY. TI IN EXISITING RETAIL STORE. TOTAL AREA 1588 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1137	17041-20000-29159	19161 W ARMINTA ST	91335	3	189B121   301	2104006026	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Issued	08/23/2017 12:00:00 AM	ADDRESS	34.21392	-118.55141	Plan check for a PV1 roof-mounted PV system. Systems size is 14.4 kWac and consists of (2) inverters and (46) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1138	17041-30000-35790	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for Title 24 only in existin space T.I. alteration of existing conference room include the new lighting and receptacles using existing circuit and existing panel in building 102 video 1 conference room. Total area: 1,064  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1139	19041-20000-09143	11045-11051 W SHERMAN WAY	91352	2	183B173    98	2315028018	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.10	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.20136	-118.37187	PANEL UPGRADE TO 600A 3P 4W GUTTER, AND (4) 200A 3P 4W SUB PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1140	16041-10001-11761	11011 W OTSEGO ST	91601	2	171B173   834	2353007033	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			01/16/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.16308	-118.37103	Change to approved set by adding (2) new panel and new ckts on the floor plan. All changes under delta-B.(((Plan check for power and energy. Project site is a new 144-unit, 5-story apartment building over 2 levels of basement parking. Work includes a 3,000-amp service. Total lighting area = 122,863 sq. ft.Note: Building application has been created under 15010-20000-04055)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1141	15041-10000-18733	5695 S GOLDENEYE CT 1-3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	33.97898	-118.41086	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'A'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'A' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1142	15041-10001-37109	18938 W SAN JOSE ST	91326	12	207B121   843	2728017011	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM			PC Approved	12/04/2015 12:00:00 AM	ADDRESS	34.26011	-118.54603	EXPEDITE PER APPLICANT REQUESTPV1, INSTALL 16.5KW ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.(56) MODULES: SUNPOWET SPR327NE-WHT(3) INVERTERS: SMA TRANSFORMERLESS - 7.7Kw, 5kW, 3.8kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1143	15041-20001-37014			3	174B109   344	2151023009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	PIN	34.1733279	-118.58153654	EXPEDITE PER APPLICANT REQUESTInstall a roof mounted solar array on a SFD, interconnect with subpanel for existing solar system on roof. New inverter is 5kW and is ungrounded. Existing system is 7.6kW. With additional 5kW, total system size is now 12.6kW.(23) new 265W pv modules connected to new 5kW inverter. MSP is 200A, derating main to 150A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1144	13041-10001-32405	16653 W HAMLIN ST	91406	6	180B137   483	2231013023	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.18859	-118.49646	Expedited RSES plan check per applicant request.(((PV1, Install 4 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter: Solaredge SE3800A-US. 16 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1145	11041-10000-21412	250 S HARBOR BLVD Ship-1of3	90731	15	018B201   623	7440030***	M2-1, [Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			Verifications in Progress	04/24/2012 12:00:00 AM	ADDRESS	33.74182	-118.27938	SITE DEVELOPMENT FOR USS IOWA BATTLE SHIP PROJECT AT BERTH 87.  SCOPE OF WORK INCLUDES PROVIDING POWER TO THE SHIP AND THE ACCESSORY BUILDINGS AT 34.5KV TO 6.6KV TO 480V TO 208/120V.   (1 OF 3 ).    (RESTROOM BUILDING WAS SUBMITED UNDER 11041-10001-21412) AND (THE TICKET BOOTH BUILDING WAS SUBMITED UNDER 11041-10002-21412).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1146	11041-10000-15922	735 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM	08/09/2011 12:00:00 AM		Issued	08/09/2011 12:00:00 AM	ADDRESS	34.04878	-118.26079	Exisiting fire alarm panel.  Adding two new auxiliary panels and 300 devices for food court area of a mall.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1147	10041-10000-07306	4483 W BEVERLY BLVD	90004	13	138B193   464	5521029009	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			04/21/2010 12:00:00 AM			PC Approved	04/21/2010 12:00:00 AM	ADDRESS	34.0764	-118.30651	remodel the bar area inside a restaurantplan chk is for Title 24 compliance	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1148	19041-30000-24472	115 S FAIRFAX AVE	90036	5	138B177   629	5511025031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.07358	-118.36166	PC (ENERGY ONLY) FOR PROPOSED INTERIOR ALTERATION TO EXISTING HOTEL LOBBY. WORK INCLUDES NEW BUILT-IN CHECK-IN KIOSK, NEW CHECK-IN COUNTER, AND NEW BUILT-IN COUNTER. AREA OF SCOPE 789SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1149	18041-20000-09817	11051 W PENDLETON ST	91352	6	198B173    32	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.23953	-118.37198	Plan check for a PV2 roof-mounted FiT PV system. System size is 1.910 MWac/2.107 MWdc and consists of (19) inverters, (5,472) modules, and (5) load centers.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1150	19041-10000-10685	5950 W JEFFERSON BLVD	90016	10	117B173   613	4204008014	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	08/20/2020 12:00:00 AM		Permit Finaled	04/12/2023 12:00:00 AM	ADDRESS	34.02115	-118.37745	POWER AND ENERGY PLAN CHCK FOR A NEW MIXED USE, 4-STORY COMMERCIAL OFFICE & RETAIL BUILDING WITH 1 LEVEL OF SUBTERRANEAN PARKING. SCOPE INCLUDES NEW 2000A SERVICE. TOTAL AFFECTED AREA IS 120,294 SQ.FTB#19010-10000-01121	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1151	14041-20002-10779	13361 N GLADSTONE AVE	91342	7	225B153   251	2509001007	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.31435	-118.43309	Fee for expedite.****Roof mounted PV system with Optimizer, system size 6.25KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1152	19041-20000-38487	357 N VISTA ST	90036	5	138B181   151	5526039017	R1V2-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	10/05/2019 12:00:00 AM	ADDRESS	34.07782	-118.35237	PLAN CHECK FOR NEW 13.5 KWH ESS FOR EXISTING SFD. SCOPE OF WORK CONSISTS OF 5KW BATTERY AND A 200A PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1153	14041-20002-28146	16501 W VENTURA BLVD Ste 615	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.1578	-118.49275	REVISIONS TO AN APPROVED SET OF PLANS PER INSPECTORS CORRRECTIONS. CONTROLS FOR LIGHTING IN ENCLOSED SPACES.TI to (E)  commercial office space in existing commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1154	18041-10000-01914	5158 N GAVIOTA AVE	91436	5	171B141   180	2261018005	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.16376	-118.48125	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 23 AC MODULES  AND NEW PANEL. TOTAL SYSTEM SIZE 7.36KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1155	17041-20000-07152	6711 N VAN NUYS BLVD	91405	6	180B149   185	2236010002	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.19252	-118.44905	Addition and change of use to one story retail and mezzanine into adult day care center (I-4) and B occupancy office space on 2nd floor.  Plan check for power and energy.  New 120/240V 3ph-4w service.  Building permit under 16014-20000-03481.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1156	13041-10000-10581	380 W WORLD WAY T36	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	per customer's request, application taken in as full plan check (T24 has already been done). power fees to be added under submittal 2. for concession space #T36-R (Michael Kors)FIRST TIME TENENT IN TBIT. SPACE 36. TOTAL AREA 800 SQ FT. PLAN CHECK FOR T24 ENERGY ONLY PER SUPERVISOR REQUEST. RETAIL STORE. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1157	10041-10000-11795	6333 W 3RD ST #120	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	10/05/2010 12:00:00 AM	ADDRESS	34.07157	-118.36014	Ti in an existing restaurant. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1158	19041-10001-13517	124 S BARRINGTON PL	90049	11	135B145   459	4365006031	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM			Corrections Issued	05/28/2019 12:00:00 AM	ADDRESS	34.06656	-118.46905	Plan check for T24 only with supplemental permit to master permit# 19041-90000-13517. TI for change of use from food establishment to Dry Cleaner. Total area apporx. 1800 sq.ftB# 19016-10000-10797	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1159	19041-10000-25870	1501 W CARSON ST	90501	15	051B193   876	7349032033	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	10/05/2020 12:00:00 AM	ADDRESS	33.83167	-118.30406	T-24, Only. Energy plan check for an Interior and exterior (E) church T.I  Scope includes new lighting and equipment with a total lighting area of 3,602-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1160	17041-10000-17567	6555 W IMPERIAL HWY	90045	11	087B165   123	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM			PC Info Complete	06/14/2017 12:00:00 AM	ADDRESS	33.93206	-118.40322	PC FOR POWER ONLY. NEW SERVICE FOR GPU UNITS FOR AIRCRAFT OVERNIGHT CONNECTIONS. PROVIDING 8 UNITS WITH FUTURE CONDUIT STUBS. SERVICE RATED 3000A @ 277/480	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1161	15041-20000-36497	20953 W HEMMINGWAY ST	91304	3	189B109   513	2109013018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.2145	-118.59038	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (25) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1162	14041-20001-23773	5143 N DENSMORE AVE	91436	5	171B141   220	2261015035	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	34.16329	-118.47731	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(54) KYOCERA KD 255 MODULES(2) SOLAR EDGE SE 6000 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1163	11041-10000-07214	811 W WILSHIRE BLVD Ste # 2050	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM			PC Approved	04/12/2011 12:00:00 AM	ADDRESS	34.04973	-118.2584	T.I.  SUITE # 2050 OF A HIGH RISE BUILDING.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1164	16041-10000-44020	6061 N TOPANGA CANYON BLVD	91367	3	177B101   111	2146025005	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.18066	-118.60615	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 18375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1165	18041-20000-18713	320 S LA BREA AVE	90036	4	135B181   238	5507008023	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.06822	-118.34383	Tenant Improvement to existing restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1166	18041-10000-47162	13217 S FIGUEROA ST 1stFlr-mezz	90061	15	078B201    60	6132004030	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	33.91183	-118.28297	Energy plan check for an new office T.I from an existing warehouse. Scope includes new lighting and equipment with a total area of 12,875-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1167	16041-10000-00115	5187 E BORLAND ROAD	90032	14	138A235   256	5221003018	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Expired	02/02/2018 12:00:00 AM	ADDRESS	34.07181	-118.17133	PV1, rooftop solar installation 3kW AC(12) KU2656ZPA(1) PVI-3.0-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1168	15041-10000-16087	608-610 W FLORENCE AVE	90044	8	102B201   919	6020028005	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Apartment			05/27/2015 12:00:00 AM			Reviewed by Supervisor	06/04/2015 12:00:00 AM	ADDRESS	33.97444	-118.28415	PLAN CHECK FOR POWER FOR SERVICE UPGRADE TO 1200AMPS. ALL PANEL BOARDS AND CIRCUITS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1169	15041-20000-11590	10915 N WHITE OAK AVE	91344	12	210B129   774	2712012016	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.26899	-118.52	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.72 KW DC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1170	18041-20000-25628	4009 N VALLEY MEADOW ROAD	91436	5	162B141    22	2285021019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM			Reviewed by Supervisor	07/27/2018 12:00:00 AM	ADDRESS	34.14389	-118.48177	Plan check for PV roof mounted and battery back up system with PV system size: 12.8kW  ACwith 41 modules and 2 inverters(7.6KW AC and 5.2KW AC) and battery backup system size: 54KW AC with 4 Tesla battery PowerWall connected to 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1171	17041-20000-33229	17900 W RIDGEWAY ROAD	91344	12	216B125   256	2601032034	(T)(Q)RE40-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2017 12:00:00 AM			Verifications in Progress	10/06/2017 12:00:00 AM	ADDRESS	34.28521	-118.5252	Install ground mounted solar photovoltaic 2 axis tracker system and replace the house load center.  (20) modules with (1) 6 kW rated central inverter.Note: Building application for mouting structure has been generated under 17020-20000-02359	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1172	16041-10000-11262	2311 N PASADENA AVE	90031	1	139-5A221 204	5205023003	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.07605	-118.21752	FULL PC FOR POWER AND ENERGY. ADAPTIVE REUSE OF AN EXISTING LIGHT INDUSTRIAL BLDG INTO 8 NEW LIVE WORK UNITS. SCOPE INCLUDES NEW 400A 120/240V 1 PHASE 3 WIRE SWITCHBOARD, AND EIGHT NEW 100A PANELS. TOTAL AFFECTED AREA IS 7590 SQ. FT.B# 16016-10000-06101	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1173	18041-20000-29744	20805 W SPRUCE CIR	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.2952	-118.58688	Plan check for PV roof mounted system, system size: 3.8kW with 12 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1174	19041-10000-39110	520 E MANCHESTER AVE UNIT 3	90003	9	097-5A207 324	6041019003	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	33.95996	-118.26583	T-24 PLAN CHECK FOR TI TO A REATIL STORE. LOAD UNDER 400A. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 891 SQ.FT. ELECTRICAL SERVICE AND PANELS ARE APPROVED UNDER 19041-10000-25012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1175	16041-20002-09655	712 S OLIVE ST Floors 1-7	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.0462	-118.25568	05-16-2019 Changes to an approved set of plan, changes include remove scope of work in the rest room level 2 changes has been clouded as delta 20.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1176	17041-20000-40406	4096 S GLENCOE AVE	90292	11	108B153  1063	4230006003	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	33.98984	-118.44257	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the restrooms only. The tenant improvement to the general space shall be under a separate permit. Total lighting area = 270 sq. ft.Note: Building application has been generated under 16016-20000-30818	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1177	18041-20000-36224	4720 N WOODMAN AVE	91423	4	168B157   444	2359020008	[Q]C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Issued	09/27/2018 12:00:00 AM	ADDRESS	34.1564	-118.43103	ti to an existing commercial building.  adding new lighting new control to new panels, newly connected load less than 400 amps.  plan check for indoor title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1178	19041-20000-34028	11544 W ALETA LANE	91342	7	213B169  1081	2530040029	RU-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.28151	-118.38389	PV1. INSTALL 4.20 KWDC SOLAR SYSTEM WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1179	12041-10000-06951	11313 W MISSISSIPPI AVE	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	05/25/2012 12:00:00 AM		Permit Finaled	08/14/2012 12:00:00 AM	ADDRESS	34.03943	-118.44302	in an existing restaurant, new lighting, and circuitsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1180	17041-10000-28376	20840 W ROSCOE BLVD	91306	3	192B109   778	2108031013	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.21978	-118.58765	REMOVE HID  FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY.Total affected 9325 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1181	16041-10001-16388	11961 W SAN VICENTE BLVD 1st-2nd flr	90049	11	129B145    76	4404025006	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Expired	10/11/2018 12:00:00 AM	ADDRESS	34.05267	-118.47147	"08/26/16Changes to an approved set of plans. All changes are made under delta 5, 6, & 7. Changes include removing/adding lighting fixtures on the floor plan, adding one sign circuit on panel ""B"", and revising title 24 forms.  (((((((TI TO RETAIL SPACE. MAKE NEW BEAUTY SALON. NEW LIGHTING. PC FOR T24 ENERGY ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1182	15041-10000-00763	2817 E CESAR E CHAVEZ AVE	90033	14	127-5A225 102	5178019004	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.04431	-118.20175	Remove HID light fixtures and replace with new LED fixtures in (E) laundromat.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1183	13041-10000-21777	349 W AVENUE 41	90065	1	147A223   220	5465020012	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.09636	-118.21364	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. SYSTEM SIZE IS 4.41 KW DC AND 3 KW AC. USING 18 MODULES AND 1 INVERTER. SYSTEM IS UNGROUNDED/TRANSFORMERLESS. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: AURORA # PVI-3.0-OUTD-S-US]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1184	18041-10000-28574	333 S GRAND AVE 34TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR TENANT IMPROVMENT IN EXISTING OFFICE BUILDING ON THE 34TH FLOOR. SCOPE INCLUDES NEW LIGHTS  IN PRIVATE OFFICES AND RELOCATION OF FIXTURES IN OPEN OFFICE WITH SOME NEW CIRUCITS FOR POWER. TOTAL AFFECTED AREA 4071 SQ.FT B# 18016-10000-21318	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1185	14041-10000-23521	2645 S LA CIENEGA AVE	90034	10	123B173   670	5065007006	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.0335	-118.3785	PV2 43.095 KW roof-mounted system including 169 hanwha solar modules and one Fronius CL 33.3KW  inverter. No fee on Final fee period due to overpayment on plan check which already covered the permit fee.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1186	16041-20000-39793	10673 1/2 N LAUREL CANYON BLVD	91331	7	207B153   517	2618001038	R2-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	PIN	34.26393321	-118.43804042	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (19) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1187	14041-20000-18659	10531 N OKLAHOMA AVE	91311	12	207B109   550	2706012008	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.26194	-118.58658	PV1 12.24KW roof-mounted system with (48) Trina solar TSM-255P modules and Solaredge p300 Powerbox Optimizers, and (2) Solaredge SE5000 inverters connecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1188	16041-10000-12313	8139 N SUNLAND BLVD	91352	6	192B173   794	2409001015	[Q]C2-1L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.21867	-118.36961	T-24, COMMERCIAL TI TO A RESTAURANT, MCDONALDS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACELS. TOTAL SQ. FT.2078	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1189	18041-20000-14831	20634 W WALNUT CIR	91326	12	219B109   358	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.29389	-118.58358	PC for rooftop solar for 3.84kW(ac)/4.02kW(dc) for SFD tract home. Installing 12 AC modules with AC disconnect.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1190	17041-20001-31524	15060 W VENTURA BLVD #150	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.15287	-118.46147	Commercial TI - new partitions and modifications to (E) lighting system.  Title 24 plan check for energy only.  Permit under 17041-20000-31524.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1191	16041-10000-39907	1601 E OLYMPIC BLVD # 316	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.02923	-118.24056	Replace HiD fixtures with new LED fixtures. Total (OUTDOOR)sqft = 15000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1192	12041-20000-11694	2423 N PANORAMA TER	90039	4	150A205   417	5432008003	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	34.10332	-118.27099	New roof mounted P.V. system (8.36 KWdc) with monitoring system.Note: Some P.V. devices permit issued under 12041-10000-04026	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1193	18041-20000-40233	1369 N BOBOLINK PL	90069	4	147B165   492	4392006004	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.09625	-118.39286	PV1.  Install 15.84 kW DC roof mounted grid tied PV system.  (48) modules with (2) 7.6 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1194	14041-20000-09246	10100 N HANNA AVE	91311	12	204B101   456	2745013018	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.25379	-118.60767	ROOF MOUNTED PV SYSTEM SIZE 3.6KW TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1195	18041-20000-35044	436 W 7TH ST	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Closed	03/26/2021 12:00:00 AM	ADDRESS	34.04637	-118.25551	temporary power for construction site 800 amp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1196	14041-20000-28819	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	submittal 2 fee due to changes in designNEW SERVICE UPGRADE TO EXISTING ELECTRICAL DISTRIBUTION SYSTEM. NEW 2000A  2400V SERVICE AND RECONNECTING EXISTING FEEDERS. PROVIDING DISTRIBUTION FOR FUTURE COGEN PROJECT THAT WILL BE COMPLETED AT LATER TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1197	19041-20001-07133	414 S VIRGIL AVE	90020	13	136-5A201 298	5077001033	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM			PC Approved	05/06/2019 12:00:00 AM	ADDRESS	34.06632	-118.2869	Expedited plan check fee.PV2.  Install 21.96 kW DC / 19.80 kW AC roof mounted grid tied PV system.  (61) modules with (2) 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1198	12041-10000-14963	4150 S GLENCOE AVE	90292	11	108B153  1207	4230006008	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM			Corrections Issued	03/05/2013 12:00:00 AM	ADDRESS	33.98875	-118.44156	TENANT IMPROVEMENT; CHANGE OF USE FROM MEDICAL OFFICE TO OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1199	19041-10000-31995	15287 W SUNSET BLVD #5-106 &-B1-M115	90272	11	129B125   862	4423016077	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.04723	-118.52537	"Adding 28 new devices to an existing Fire Alarm System in the building for ""Lulullemon"" in Space #5-106"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1200	17041-20000-04315	1838 N WESTERN AVE	90027	13	150A193   229	5544006047	C4-1D	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.10468	-118.30911	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM RETAIL TO VOICEOVER STUDIO.  1774 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1201	15041-20001-43347	16964 W ENCINO HILLS DR	91436	5	159B133    74	2287005059	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.13479	-118.50213	RSES expedited plan check per applicant request.  PV1.  Install 11.6 kW AC roof-mounted, utility-interactive PV system.  (2) SMA SB5000TL-US-22 transformerless inverters with (37) SunPower X21-345 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1202	15041-10001-36944	3096 N HOLLYRIDGE DR	90068	4	157-5A191 101	5583021008	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Expired	03/09/2018 12:00:00 AM	ADDRESS	34.12507	-118.3173	Supplemental PC and Permit 7.6kW system, (35) total modules (1) SE7600A-USOnline permit under 15041-90000-36944<<Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1203	16041-10000-22811	777 S FIGUEROA ST ste 3650	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM	ADDRESS	34.04828	-118.26116	PC for energy only to a commercial building. TI office in suite 3650. Adding lighting and rceptacles. Total sqft = 3407	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1204	17041-20000-42191	4720 N VINELAND AVE	91602	2	168B173   668	2421026006	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.15615	-118.37007	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL. 1088 SQFT.""COMPLY WITH DEPARTMENT ORDER effective date11/24/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1205	17041-10000-25848	6100 S HOOVER ST	90044	9	105B201   842	6004024029	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM			Reviewed by Supervisor	08/30/2017 12:00:00 AM	ADDRESS	33.98398	-118.28686	NEW 1 STORY COIN LAUNDRY BLDG. FULL PC FOR POWER AND ENERGY. NEW 1200A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1206	18041-20000-00579	9320 N MASON AVE	91311	12	198B109    87	2748022056	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.24018	-118.5796	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 2,500 Amps.Note: This application shall not include the review or permit of any load or subpanels. Application strictly for service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1207	11041-10000-00827	2647 S CHARITON ST	90034	10	123B169   505	5065010021	[Q]R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.03482	-118.37992	CIRCUITS FOR PAKING LOT LIGHTING PUMPS AND ELEC GATE.((((((((((((((( plan check for title 24 out door.)))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1208	17041-10000-02167	5080 W MELROSE AVE	90038	4	141B193   615	5522009029	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Issued	02/13/2017 12:00:00 AM	ADDRESS	34.08336	-118.31075	"PC FOR ENERGY T24 ONLY. T.I.  ADDITION  OF LIGHTS IN A CARWASH, TOTAL AREA 10992 SQ FT. ""COMPLY WITH DEPARTMENT ORDER effective date 03/03/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1209	13041-10001-22260	15611 W VANDORF PL	91436	5	165B141   477	2285007031	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.14509	-118.47399	EXPEDITE PLAN CHECK PER APPLICANTS REQUEST.PV1. ROOF MOUNTED SOLAR ARRAY. 2 STORIES. SYSTEM SIZE: 14.81KW. TRANSFORMERLESS. 57 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1210	12041-10000-27027	9653 N FULLBRIGHT AVE	91311	12	201B113   665	2748013052	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.24617	-118.57804	PV1 Solar Installation 4.16 kW.  ROOF MOUNTED Enphase microinverters standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1211	18041-20000-40995	7912 W MELROSE AVE	90046	5	141B177   603	5527017014	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Issued	11/07/2018 12:00:00 AM	ADDRESS	34.08366	-118.36216	New 200A 240/120V 1ph-3w service for existing commercial shell space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1212	18041-10000-22979	3456 W 3RD ST	90020	13	135B197   184	5501024028	(Q)P-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.06888	-118.2909	PLAN CHECK FOR TITLE 24 ONLY FOR OUTDOOR LIGHTING FOR EXISTING BUILDING - TOTAL AFFECTED AREA = 7241 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1213	10041-10000-10292	11700 W NATIONAL BLVD	90066	11	120B153  1083	4250001026	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	Commercial			06/01/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	PIN	34.02218411	-118.43889497	"TI IN AN EXISTING COMMERCIAL SPACE. CHANGING ""BLUCKBUSTER VIDEO"" TO ""CHASE BANK"". PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1214	17041-10000-16347	1529 W VENICE BLVD	90006	1	126B197   129	5056006018	CM-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.04439	-118.28736	PLAN CHECK FOR POWER AND ENERGY FOR (BUILD NEW 2 STORY ADDITION (FOOD STORAGE BLDG); 1 STORY (E) BLDG). SCOPE CONSIST OF NEW 800A DISTRIBUTION BOARD(3 PHASE - 120/240). TOTAL SQ. FT. 6141	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1215	17041-10000-29576	740 N CAHUENGA BLVD	90038	13	141B185   381	5533032005	CM-1VL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.08462	-118.3286	TI FOR LIGHT CLOTHING PRODUCTION. NO APPEARANT CLASSIFIED LOCATIONS NOTED ON PLANS. PC FOR T24 ENERGY ONLY LIGHTING UPGRADES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1216	14041-10000-07120	18555 W VENTURA BLVD	91356	3	174B125   543	2160007012	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Public Safety Only			03/17/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.1697	-118.53779	New fire warning system for commercial building with 4 tenant spaces- one space being occupied	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1217	19041-20000-41030	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1218	15041-20002-03583	1770 N ORCHID AVE	90028	13	150A185   365	5548004027	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.10361	-118.33998	08-10-2015 Change to approved set of plans; changes includes addition of 4 smoke dectors in ADA storage rooms.{{{{{INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP  AND 63 DEVICES.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1219	13041-10000-26108	380 WORLD WAY #T44-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of led sel-illuminated signs on the external walls of a the tenant space Hugo Boss on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1220	10041-20000-24394	14411 W HAMLIN ST	91401	6	180B149   586	2237014022	[Q]C1-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.00	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.18885	-118.44705	T.I. to medical clinic.  Install branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1221	16041-20005-38115	21425 W VANOWEN ST	91303	3	183B105   951	2138011023	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.19399	-118.59858	6/11/2019changes to an approved set of plans.  changes to feeder RDB2 and RDB4.  this is plan check only.  ((((9/21/18changes to an approved set of  plans.  changes noted delta 7 only.  changes to revise lighting fixtures and update energy calculations.  no change in load no new equipment.  this is plan check only.)))) ((((Full PC for new 6 story with 1 level of basement. 174 unit apartment. All new equipment. (2) New main switchboards rated at 5000A 120/208V 3 phase 4wire AND 2000Amps 120/208V 3phase 4wire. 17 typical units. Total sqft = 126,537.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1222	13041-10000-29590	2485 S ARMACOST AVE	90064	11	120B149   165	4257002011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			Reviewed by Supervisor	11/04/2013 12:00:00 AM	ADDRESS	34.02776	-118.44796	PV1.  Install 4 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US.  16 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1223	17041-10001-22255	12152 W VAN NUYS BLVD	91342	7	213B165   133	2531026005	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Issued	01/11/2018 12:00:00 AM	ADDRESS	34.28374	-118.39757	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES ADDITION OF NEW MODULE (SINGLE) ON ARRAY 1. TOTAL SYSTEM SIZE IS NOW 4.75KWAC.ADDITIONAL PERMIT FEES TO REFLECT A SINGLE MODULE. Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1224	17041-10000-24702	150 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.07452	-118.32343	RESTAURANT TI FOR URM BUILDING. LIGHTING UPGRADES. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1225	14041-20006-17303	5800 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM			PC Approved	10/18/2016 12:00:00 AM	ADDRESS	34.09728	-118.31693	10/18/2016 Changes to an approved set of plans. Changes have been made to the OCPD of the EM generator. All changes have been clouded.9.1.2016 - Plan check for changes to approved set. Update panel schedules and floor plans to reflect as built conditions. Removing first floor lobby lighting from scope of project. Changes clouded delta 15.8/18/2016Plan check for changes to approved set.  Add series rating for LA panels. Add insulated ground conductor for flex conduit.  Revised various mechanical equipment. Changes clouded delta-14. 6/11/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 2 and Delta 3. Changes include downsizing the EM generator to 800 kW from 1000 kW, the EM distribution board has been separated to have sections, 10 new lighting control panels, the addition of 2 new civil sump pumps, addition of fire smoke damper circuits, relocation of additional circuits and upsizing of water heater circuit breakers. *****Previous Work Description*****A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1226	12041-20000-10155	2446 N APOLLO DR	90046	4	153B177   288	5569022018	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2012 12:00:00 AM			PC Approved	05/07/2012 12:00:00 AM	ADDRESS	34.11588	-118.36555	Change of main circuit breaker from 125A to 100A and adding 40A dedicated breaker for solar. Bus rating is 125A. Permit under 12041-20000-06934 (originally express permit)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1227	14041-20000-24100	11800 N BABBITT AVE	91344	12	216B133   637	2606017014	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.28473	-118.50856	PV1.  Install 6.05 kW roof-mounted, utility-interactive PV system.  Center-fed service panel with derating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1228	10041-20000-06500	915 W WILSHIRE BLVD SUITE 1660	90017	9	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.05069	-118.2599	TENANT IMPROVMENT ON 16TH FLOOR, WORK INCLUDES  NEW POWER,  LIGHTING & FINISHES.  this plan check is title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1229	12041-10000-02920	9600-9636 W PICO BLVD # 505	90035	5	132A167   365	4306001037	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	03/28/2012 12:00:00 AM	ADDRESS	34.05501	-118.39777	Plan check only T24 Energy with Emergency lighting for Counseling facility suite #505 &506	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1230	18041-10000-34196	2741 S COMPTON AVE	90011	9	117A211   302	5114038013	MR1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.01331	-118.24829	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1231	19041-10002-24554	704 S HARTFORD AVE pv2	90017	1	130-5A205 165	5143009002	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	02/13/2023 12:00:00 AM	ADDRESS	34.05179	-118.26737	change of an approved set for pv2 system. change under delta 2. change include changing PV panel model and adding 5 more panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1232	11041-20000-05382	3415 S SEPULVEDA BLVD 3rd Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	"T.I. for a high rise building.  Install general/emergency lighting in elevator lobby and corridor.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1233	18041-10001-39977	17337 W RAYEN ST	91325	12	195B129   211	2768018003	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.2323	-118.51268	Fees are $0 due to assembly bill 1414. Changes to approved set of plans. relocating modules on the roof-top.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1234	14041-10000-12143	11686 W TUXFORD ST	91352	6	192B169   433	2632023027	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.22279	-118.38707	Title 24 only - Remove HID fixtures and replace with flourescent fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1235	19041-10000-17239	6216 N ORION AVE	91411	6	177B145   290	2242006012	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM			Reviewed by Supervisor	05/15/2019 12:00:00 AM	ADDRESS	34.18354	-118.46964	PV1. NEW ROOFTOP SOLAR SYSTEM IN A SINGLE FAMILY DWELLING. CONSIST OF 45 MODULES (LONGI SOLAR 305), 45 OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTER (SE 11400H-US). SYSTEM SIZE IS 13.73 KWdc AND 11.4KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1236	12041-10000-07738	1155 S ALVIRA ST	90035	5	132B173  1000	5087011004	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	05/16/2012 12:00:00 AM	ADDRESS	34.05533	-118.37213	New 6.08kw  photovoltaic system for an existing single family residence on the rooftop.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1237	16041-10000-25353	10250 W SANTA MONICA BLVD 3750	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER AND ENERGY. NEW HEALTH CLUB TENANT SPACE IN EXISTIN SHELL IN CENTURY CITY MALL.TOTAL AREA 28243 SQ FT.SHELL#	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1238	18041-10001-17326	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	"DELTA ""DCN013"" Changes to approved plans in LAX.<<<<Full plan check for a change of use area located in LAX terminal-2 level 1, 2 and 3. Scope includes new lighting and equipment.>>>>Building referrence application #: 18014-10002-00667"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1239	19041-10000-10334	1208 W PASEO DEL MAR	90731	15	006B193   319	7470027025	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.71341	-118.30624	PC to 1 ESS and a new panel to be connected to an existing PV System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1240	19041-10000-53930	2108 S BUCKINGHAM ROAD	90016	10	123B185    97	5061006019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.03691	-118.33765	[EPlan] PV1,  Installation of 16 roof mounted solar PV panels @ 5.200kwDC/4.717kwAC- CEC / 3.8 kwAC with 1 inverter, 16 optimizers - (N) 200A MSP upgrade & MSP relocation required by LADWP. Existing MSP will be turned into a 100A sub panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1241	12041-10000-22329	2231 S BARRINGTON AVE	90064	11	123B149   480	4260012027	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			Verifications in Progress	11/30/2012 12:00:00 AM	ADDRESS	34.03337	-118.44727	Plan check power and energy for existing retail building (Office Depot). New electrical system with 1200A service. Existing building was fire damaged.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1242	19041-10000-14025	5536 N FULCHER AVE	91601	2	174B173  1122	2350003060	R4-1L	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Apartment			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	07/10/2020 12:00:00 AM	ADDRESS	34.17103	-118.37291	PC for installation of a new fire alarm system for 36 units. System includes 1 FACP, 3 Power Booster, and 130 devices	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1243	16041-10000-19518	700 W 7TH ST G280	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/03/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	Plan check for Title 24 with 1089 sqft. ****For fee reference onlyTI in existing mall space Suite G280 - New demising wall and storefront. New partition and new accessible bathroom.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1244	15041-10000-30091	318 N LA BREA AVE	90036	5	138B181   308	5525032009	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.07682	-118.34384	PC for energy only to a commercial site (retail). Scope of work: adding new lighting and receptacles. Sq ft = 2000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1245	18041-10002-47011	4252 S CRENSHAW BLVD	90008	10	114B185   958	5024017007	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Apartment			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.00668	-118.33443	PLAN CHECK ONLY,. Changes to an approved set of plans noted under delta 7 only. Scope of work includes the change of feeder size from 80A to 60A only. ______________________________________________________Bld application: 18010-10000-02786FA system under #19041-10000-05036	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1246	19041-30000-39564	5950 W COLGATE AVE GAREAGE-4	90036	4	135B181   159	5509005008	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.06917	-118.35267	SERVICE UPGRADE TO 800 AMP ONLY TO GARAGE AREA 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1247	11041-10000-10670	4725 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM			PC Info Complete	08/16/2011 12:00:00 AM	ADDRESS	34.04694	-118.33991	CHANGE OF USE FROM RETAIL TO RESTAURANT.  NEW PANELS AND CIRCUITS INCLUDING LIGHTING.  (POSSIBLE NEW TRANSFORMER, VERIFY NEW & EXISTING WITH DESIGNER ON SINGLE LINE).   PLAN CHECK FOR POWER AND ENERGY W/ EMERGENCY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1248	16041-20000-37010	19119 W LULL ST	91335	3	186B121    82	2104012005	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Issued	10/19/2016 12:00:00 AM	ADDRESS	34.20941	-118.54995	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1249	14041-20000-20189	16156 W SAN FERNANDO MISSION BLVD #3, #4, #5	91344	12	210B141   555	2667001016	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.27176	-118.48408	Fire damage repair for unit #3, #4, and #5.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1250	19041-10000-50629	1820 S ALSACE AVE	90019	10	126B181   567	5067017005	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.04288	-118.35091	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 13 MODULES (AXITEC SOLAR 310) AND 7 MICROINVERTERS (APS YC600). SYSTEM SIZE IS 3.84KWAC AND 3.9KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1251	18041-10000-09694	2223 W BERKELEY AVE	90026	13	142-5A207 233	5423010013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.08443	-118.26173	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 17 MODULES (EAGLE PERC60 290w), OPTIMIZERS (SOLAR EDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE5000A-US). SYSTEM SIZE IS 5KWac AND 5.44KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1252	17041-10000-35147	8202 W MELROSE AVE	90046	5	141B173   467	5528012033	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM			PC Info Complete	10/13/2017 12:00:00 AM	ADDRESS	34.08352	-118.36822	3/29/18 THIS IS PLAN CHECK ONLY!!PERMIT FEES PAID WITH EXPRESS PERMITS17041-10000-33436 FOR (E) B. CIRCUITS17041-10001-33436 FOR (N) B. CIRCUITSPC for T24 only for new lights and receptacles. Installing new circuits, lights, receptacles and equipment.  Total area of 4175sqft.  Inspector to verify the maximum relamping rated wattage of chandelier luminaires.***************************************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1253	16041-10000-16945	14006 W RIVERSIDE DR #20	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC FOR RETAIL. EYEGLASS STORE WITH 1 EYE EXAM ROOM. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1254	15041-20003-35922	10450 N DE SOTO AVE	91311	12	207B109   628	2706015033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	34.26047	-118.58835	[[03/23/16 changes to approved set of plans. changes to the roof layout only. no additional changes]]02/24/2016 Changes to an approved set of plans. Changes have been made to reflect on-field installation. Changes include clarifications about the main service panel and updated service load calcs.*****Previous Work Description*****PERMIT FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.Plan check for a PV1 roof-mounted PV system. System size is 13 kWac and consists of (2) inverters, (48) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1255	15041-10001-25580	23401 W FRIAR ST	91367	3	180B093   933	2035018032	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM			Reviewed by Supervisor	08/17/2015 12:00:00 AM	ADDRESS	34.18567	-118.63694	EXPEDITED RSEC PC PER APPLICANT REQUEST(((INSTALLMENT OF 10.2 KW DC ROOF MOUNTED SOLAR SYSTEM FOR A SINGLE FAMILY HOME. (40) MODULES YIMGLIENERGY YL255P-29B. (1) INVERTER: SOLAR EDGE SE7600A-US.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1256	17041-10000-20171	9224 N SUNLAND BLVD	91352	7	198B173   173	2544012902	RA-1-K, RA-1VL	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.23649	-118.36727	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1257	12041-10002-10461	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM			PC Approved	09/07/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	REVISION TO THE APPROVED PLAN. CHANGE ONE TYPE OF LUMINAIRES TO LED LIGHTS. PLAN CHECK FOR THE CHANGE IN T24. (((((((((((Change to Indoor lighting, new transformer and 100A panel with circuits for a medical clinic.  Full plan check.  Not a state licensed building, per engineer.  NOT CHECKED FOR OSHPD.))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1258	10041-20000-00443	6732 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			01/11/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Finaled	04/07/2010 12:00:00 AM	ADDRESS	34.11828	-118.34021	Replacing existing exist sign with combination of emergcy and exist sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1259	19041-20000-10436	5806 W 74TH ST pv1	90045	11	102B169   288	4104007005	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Closed	03/04/2024 12:00:00 AM	ADDRESS	33.97318	-118.38236	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1260	11041-10000-04525	6351 W WILSHIRE BLVD	90048	5	135B173   825	5510028008	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM			PC Approved	03/08/2011 12:00:00 AM	ADDRESS	34.06381	-118.36703	T24 only for remodeled existing space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1261	14041-20000-30144	1136 W 6TH ST	90017	1	132A207   615	5143024015	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.05447	-118.26366	INSULATION OF A NEW FIRE ALARM SYSTEM. 8 STORY BUILDING. 1 FACP, 2 RPS, 301 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1262	14041-20000-24571	740 S OLIVE ST #106	90014	14	127-5A209  18	5144013034	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.04537	-118.25644	CHANGE OF USE FROM OFFICE TO A GYM STUDIO AND INTERIOR T.I.  PLAN CHECK FOR ENERGY ONLY - 2013 BUILDING ENERGY EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1263	19041-20000-04002	4659 N ATOLL AVE	91423	4	168B157   545	2360025030	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.1556	-118.42055	Plan check for a PV1 roof-mounted PV system. System size is 11.88 kWdc/10.93 kWac-CEC and consists of (36) micro-inverters, (36) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1264	16041-20000-20924	6203 W 87TH ST	90045	11	096B165   713	4123003022	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	33.95871	-118.39365	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOE ENERGY ONLY.  TOTAL SQUARE FOOTAGE 450.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1265	18041-30000-34721	601 S FIGUEROA ST 25TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT TO 25TH FLOOR INCLUDING ADDITIONAL PARTITIONS, NEW LIGHTS AND RECEPTCALE, TOTAL AREA: 9625 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1266	19041-30000-51982	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	02/13/2020 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.16603	-118.52861	PLAN CHECK FOR T24 ONLY, SCOPE OF WORK IS NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 3044 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1267	19041-10000-51623	11845 W VOSE ST	91605	2	183B169   162	2321004900	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	11/02/2020 12:00:00 AM		Permit Finaled	02/14/2023 12:00:00 AM	ADDRESS	34.19964	-118.39174	FULL PC FOR POWER AND ENERGY. POWER PLAN CHECK FOR GROUNDWATER REMEDIATION SYSTEM, TREATMENT SYSTEM, GENERAL SITE IMPROVEMENTS.  TI FOR EXISTING WAREHOUSE. SCOPE (984)SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1268	14041-10000-14584	909 E COLON ST	90744	15	036B209   293	7426003001	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	33.79161	-118.25174	roof-mounted 1470 KW DC SOLAR SYSTEM0$ PERMIT FEE IS IN ACCORDANCE WITH SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1269	11041-10000-20657	1411-1417 S ELKGROVE CIR BLDG 9	90291	11	111B149   609	4243002070	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.0008	-118.4583	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1270	19041-10000-13369	9900 N VANALDEN AVE	91324	12	201B121   114	2729005009	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.25035	-118.54906	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 30 MODULES (LG320N1K-A5) , 30 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE7600H-US).  SYSTEM SIZE IS 9.6KWdc and 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1271	16041-20000-00120	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	PC FOR AN EXISITING FIRE ALARM SYSTEM. SCOPE INCLUDES UPDGRADING TWO FIRE ALARM CONTROL PANELS, REMOVING TRANSPONDERS, AND UPGRADING THE AUDIO PANELS. REPLACING ONE FOR ONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1272	19041-10000-45675	19755 W VANOWEN ST	91306	3	183B117  1051	2135022046	(Q)C4-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	05/04/2020 12:00:00 AM	ADDRESS	34.19397	-118.56386	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT TO EXISTING SPACE. SCOPE INCLUDES NE 125A SUB-PANEL CONNECTED TO EXISTING 200A  PANEL. SCOPE ALSO INCLUDES LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 784 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1273	18041-10001-14855	209 N WESTERN AVE	90004	4	138B193   731	5517004022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2115.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.07499	-118.30934	DELTA 1 CHANGES TO AN APPROVED SET, T-24 ONLY. REMOVING TIMECLOCK AND OVERRIDE AND REPLACING WITH OCCUPANCY SENSORS. (((((PLAN CHECK  FOR T24 ONLY, CHANGE OF USE FROM RETAIL TO RESTAURANT. INSTALL (1) 100A NEW PANEL FOR NEW LOADS/CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1274	15041-10001-04121	330 E 2ND ST # C	90012	14	129A213   113	5161022022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	34.04859	-118.24099	((((5/22/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO THE LIGHTING FIXTURES AND ENERGY CALCS.CHANGE OF USE FROM RETAIL TO RESTAURANT.OCCUPANT LOAD IS LESS THAN 50PLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1275	13041-10000-24732	241 S CORONADO ST	90057	13	136-5A203 299	5155025022	R3-1	Central	Westlake	Greater Echo Park Elysian	YES	2086.20	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.06702	-118.27739	PV1.  Instal 4.32 kW DC roof-mounted solar array of 16 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1276	16041-10000-05606	1245 W WILSHIRE BLVD 6TH FLR	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM			PC Info Complete	05/18/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	TI TO AN EXISTING MEDICAL BUILDING SIXTH FLOOR.  FIRST TIME TENANT. PLAN CHECK FOR ENERGY AND POWER.  ELECTRICAL SERVICE APPROVAL PLANS SUBMITTED FOR REFERENCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1277	19041-10000-26138	6901 S MAIN ST	90003	9	102B201   354	6012009902	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	33.9772	-118.27422	PC FOR NEW FA FOR NEW 4 STORY BUILDING. 1 FACP AND 190 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1278	11041-20001-16208	1224 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/30/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.2924	"Revision to approved plans. Change from 3.23 KW to 9.67KW PV solar equipment (max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) system for an apartment Bldg"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1279	13041-10000-10580	380 W WORLD WAY T52	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	per applicant's request, application taken in as a full plan check for power (T24 has already been done). power fees to be added under submittal 2. for concession space #T52-R (Fred Segal)FIRST TIME TENANT OF RETAIL SPACE IN TBIT. PLAN CHECK FOR T24 ENERGY ONLY PER SUPERVISOR REQUEST. TOTAL AREA 2000 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY. WORK DONE IN SPACE T52.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1280	15041-20000-35239	6008 N BONNER AVE	91606	2	177B173  1147	2337004025	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Expired	11/21/2017 12:00:00 AM	ADDRESS	34.17969	-118.37402	PV1, ROOF MOUNTED SOLAR SYSTEM 5.565 KW(21) modules #KU2656ZPA(1) inverter PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1281	17041-20001-45075	20251 W CHAPTER DR	91364	3	165B113   109	2174023034	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.15006	-118.57724	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.11.4kW ungrounded system. (33) 305W pv modules.Each module has a 320W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1282	19041-20000-14669	18306 W EDDY ST	91325	12	195B125  1041	2786003039	[Q]M1-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			Verifications in Progress	05/16/2019 12:00:00 AM	ADDRESS	34.2274	-118.53186	TI and change of use from retail/office/warehouse/garage to retail/office/hydroponic agriculture enterprise.  New 1200A 480Y/277V 3ph-4w service with (E) 400A 240/120V distribution.  Plan check for power and energy.Building permit issued under 18016-20000-37554.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1283	19041-20000-09551	7304 N JORDAN AVE	91303	3	186B105   848	2111013022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.20311	-118.60273	INSTALLATION OF A 20.13KW DC/17.11KW AC CEC/22.8 KW AC ROOFTOP MOUNTED PV SYSTEM ON A EXISTING COMMERCIAL LOW RISE. SCOPE OF WORK INCLUDES (61) PANASONIC 330W PV MODULES WITH P400 OPTIMIZERS, (3) 7.6KW SOLAR EDGE INVERTERS, AND A 125 PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1284	14041-20001-05285	3831 N WINFORD DR	91356	3	162B121    38	2177047021	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.14067	-118.55035	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 9.8KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1285	12041-20000-20855	7618 N JELLICO AVE	91325	12	186B129   195	2202002012	RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.20915	-118.51727	Photovoltaic system on roof of a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1286	18041-30000-18412	10330 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.25812	-118.57961	Design build. Energy plan check for a grocery store T.I. Replacing new light fixture with LED retrofit, one for one replacement. No new wiring included. Total area is 15,000-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1287	14041-10000-32439	200 WORLD WAY # 234	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER AND ENERGY. TERMINAL 2 BUILT BURGER (234). TI. TOTAL AREA  915 SQ FT.PLAN CHECKER TO VERIFY THE FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1288	10041-20000-18858	6529 N VAN NUYS BLVD	91411	6	180B149   538	2236015001	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02, 1281.00	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	04/28/2011 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	PIN	34.18953209	-118.44926262	Plan check power and energy alteration and addition to commercial retail building. New 1600A service electrical system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1289	17041-20000-41017	2069 N ARGYLE AVE	90068	4	151-5A189 314	5586001046	R3-1XL	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Issued	01/24/2018 12:00:00 AM	ADDRESS	34.10874	-118.32544	Note: $0.00 permit fee due to CA Senate Bill 1222pv2install roof mounted pv system sized 40kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1290	17041-20001-18229	17638 W RAYMER ST	91325	12	192B129    51	2787029005	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	34.22646	-118.51894	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv sysetm, roof-mounted on SFD.10kW ungrounded sysetm. (40) 330W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1291	12041-10000-29604	23644 W VANOWEN ST	91307	3	180B093    99	2036026044	[Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			12/07/2012 12:00:00 AM	01/10/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.19304	-118.64186	RETAIL OFFICE. PLAN CHECK FOR TITLE 24 WITH NO EMERGENCY LIGHTING. SQUARE FOOTAGE IS 4220.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1292	11041-10000-06363	4375 S GLENCOE AVE SUITE D-4	90292	11	105B153    86	4212004004	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	05/19/2011 12:00:00 AM	ADDRESS	33.98565	-118.43823	T.I.  EXISTING BAGEL SHOP.  REPLACING LIGHTING FIXTURES.  TITLE 24 PLAN CHECK ONLY.  SUITE D-4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1293	16041-10000-43864	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			Corrections Issued	12/29/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for conduit only.  Plan reflect electrical conduit layout for infrastructure underground  North baggage structure.Permit for conduit will be pull at the later time	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1294	18041-10000-01596	14417 W ROSCOE BLVD SUITE P	91402	6	192B149   365	2638022050	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.22174	-118.4472	CONVERTING PORTION OF RETAIL SPACE TO A RESTAURANTPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1295	14041-20001-00932	5732 N CHICOPEE AVE	91316	5	174B129   348	2254020014	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM			PC Approved	02/27/2014 12:00:00 AM	ADDRESS	34.17506	-118.51214	EXPEDITE FEES ONLY.          <<,NEW ROOF MOUNTED PV SYSTEM FOR SFR.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1296	16041-20000-01945	10250 W CONSTELLATION BLVD Levels 31-35	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Tenant improvement to (E) commercial office space in (E) commercial highrise building.  Plan check for energy only.  4,990 sq. ft. of stairwell lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1297	11041-10000-04942	5404 S JANDY PL	90066	11	105B161   885	4211006004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM			PC Approved	03/14/2011 12:00:00 AM	ADDRESS	33.98159	-118.41622	EAVE FLUSH LIGHTING FOR HARDSCAPE LIGHTINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1298	18041-10000-22251	1708 W BEVERLY BLVD	90026	13	135A207   198	5153001004	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	10/04/2019 12:00:00 AM		Issued	10/04/2019 12:00:00 AM	ADDRESS	34.06453	-118.26605	PC FOR TITLE 24, ENERGY ONLY FOR A TEMPLE TI. TOTAL CONNECTED LOAD <400ASCOPE INCLUDES NEW SERVICE (400A), EQUIPMENT PANELS AND LIGHTS. TOTAL AFFECTEDD AREA 34950 SQ.FT (INDOOR AND OUTDOOR) BUILDING# 12010-10000-01634.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1299	19041-20000-23818	141 N ROBERTSON BLVD	90048	5	138B169   263	4334001017	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	05/26/2020 12:00:00 AM	ADDRESS	34.07639	-118.38389	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 972 sq ft. B#19016-20000-18197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1300	13041-20000-34231	17822 W GREYHAWK PL	91344	12	216B129   280	2601066002	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.28732	-118.52047	"New 12.48 kw rooftop pv system for an existing sfr.  System is UNGROUNDED. "" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1301	16041-20001-10012	15416 W LASSEN ST	91343	7	201B145   645	2656003014	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.24986	-118.46828	"[[2/17/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO T24 ENERGY. CHANGES TO FIXTURE ""A"" AND ""AE""]]]]CHANGE OF USE FROM ARCADE TO A (NEW) COIN LAUNDRY.  NEW 400MS. TOTAL AREA: 1,950 SQ.FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1302	17041-10001-15538	20420 W VIA GALILEO	91326	12	219B109   295	2701056014	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.29602	-118.57929	CHANGE TO APPROVED SET OF PLANS. ADDITION OF DWP METER SOCKET AND CHANGE TO INTERCONNECTION. CHANGES CLOUDED RED. PC ONLY. PERMIT ALREADY COVERED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1303	17041-10000-38822	7955 W HILLROSE ST	91040	7	207A195     1	2556031006	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.26344	-118.30677	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ FT 46750	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1304	14041-10000-35835	1801 S LA CIENEGA BLVD SUITE 301	90035	10	126B173     3	4303024003	C1-1, C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.04434	-118.37702	TI to (E) 3850 sq ft beauty school.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1305	16041-20000-44241	13009 W SATICOY ST	91605	2	186B161   371	2303021014	CM-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.2071	-118.41608	remove existing hid fixtures and replace with new led.  plan check for energy outdoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1306	17041-20000-13797	13307 W SAYRE ST	91342	7	228B157   721	2511007022	R1-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Issued	05/11/2017 12:00:00 AM	ADDRESS	34.31987	-118.42304	"PV1. ROOFMOUNTED SOLAR MICROINVERTER SYSTEM. SYSTEM SIZE: 3.99 KW""COMPLY WITH DEPARTMENT ORDER effective date 02/24/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1307	13041-10000-11346	380 WORLD WAY T47-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	New tenant space in Tom Bradley Intl Terminal, level 4, space T47-R for Victoria's Secret shop.  785 sq ft. Scope of Work includes power and energy/lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1308	19041-20001-12669	11124 N AMESTOY AVE	91344	12	210B133   400	2697024020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	ADDRESS	34.27284	-118.50632	5/30/2019changes to an approved set of plans.  changes to the plans layout to reflect field conditions.  this is plan check only.   Installation of 13.5 kWh energy storage system and associated distribution equipment/critical backup panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1309	17041-10000-36752	507 W 95TH ST	90044	8	093A201    40	6039011008	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	33.95021	-118.28316	PC for rooftop solar for new 3.8kW system with 17 new modules, 17 optimizers and central inverterfor SFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1310	17041-20000-00644	18562 W LEMARSH ST	91324	12	204B125   277	2729012026	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.25488	-118.53825	PV1.  Install 12.915 kW roof mounted grid tied PV system.  (41) modules with (2) 5.2 kW rated central inverters.$18.80 permit fee per Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1311	12041-10000-30654	380 W WORLD WAY #T57	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	04/22/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I.  Remodel for airport concession space # T57.  Plan check is for Title 24 only using the area category.  Applicant wanted to have the T-24 plan check as back room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1312	14041-10001-03090	4507 N ATOLL AVE	91423	4	165B157    64	2360027021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.15241	-118.42053	Expedited RSES plan check per applicant request.{{PV1, Install 7.25 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE6000A-US-ZB-U(29) Modules: YINGLI YL250P-29b}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1313	18041-10000-29007	3465 W 6TH ST	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Info Complete	10/01/2018 12:00:00 AM	ADDRESS	34.06373	-118.29761	PC FOR RESTAURANT TI  FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 2469 SQ.FTSCOPE INCLUDES NEW EQUIPMENT, CIRCUITS AND LIGHTS. OCC LOAD =92B# 18016-10000-21180	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1314	17041-30001-25936	208 S LINCOLN BLVD	90291	11	111B145   553	4243014026	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.00177	-118.46833	08-22-2017 Changes to an approved set of plan. Changes has been clouded. (Plan check per inspector request.). Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1315	18041-20000-30764	7918 W ELECTRA DR	90046	4	150B177   210	5569011021	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.10738	-118.36464	Installation of 18.15 kWdc / 16.95 kWac ground mount roof mounted grid tied PV system.  (55) modules with 7.6 and 6.0 kW rated string inverters.  $0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1316	13041-20000-30144	2051 N CUMMINGS DR	90027	4	151-5A195 137	5589003014	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.10868	-118.30205	New rooftop PV system for an existing single family dwelling.  SYstem uses Enphase microinverters.(((($0.00 PERMIT FEES - SENATE BILL))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1317	15041-20002-35457	8001 N VENTURA CANYON AVE	91402	6	189B157   306	2213019040	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Approved	05/05/2017 12:00:00 AM	ADDRESS	34.21649	-118.42885	5/5/2017changes to an approvd set of plans.  changes reflect field conditions.  changes noted delta 2.this is plan check only.(((((Replacement of electrical system in Kaiser Permanente office Building 6.Re-feeding electrical services, replacement of switchgear, panelboards and refurbishing (E) Electrical equipments. Derating Main service from 1200A to 1000A.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1318	18041-20001-10121	8505 S WESTERN AVE	90047	8	097-5A193 263	6035032039	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM			PC Info Complete	03/23/2018 12:00:00 AM	ADDRESS	33.96069	-118.30921	3/23/2018changes to an approved set of plans.  changes include service increase to 800 amps and reconnect all existing loads noted delta only, no change in fault current.  plan check for power.(((Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from grocery store to charter school/tenant improvement. Total lighting area = 11,465 sq. ft. Occpuant load is 228.  Note: Building application has been generated under 16016-10000-12653.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1319	18041-10001-24814	3323-3333 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			Plans on Hold	03/01/2019 12:00:00 AM	ADDRESS	34.02738	-118.37232	PC only for stamping and perforating of a second set to the previously approved set. Original scope of work is (Install new Fire Alarm System on New 910 unit mixed-use building. (4037) devices)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1320	12041-20000-27490	4612 N CARTWRIGHT AVE	91602	4	168B177   876	2421033007	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Expired	01/06/2015 12:00:00 AM	ADDRESS	34.1543	-118.36357	Photovoltaic system on roof of single family dwelling using enphase M215 inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1321	13041-10000-35614	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	33.98179	-118.40283	PLANCHECK FOR POWER AND ENERGY. CORE AND SHELL. NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY 29895 SF WITH NEW SURFACE PARKING LOT1 OF 2. BUILDING 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1322	12041-10000-17994	500 S VIRGIL AVE 501	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM			PC Approved	08/01/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Plan check for energy and emergency lighting. scope of work does not include critical care areas. 1525 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1323	14041-10000-31310	12224 W TRUESDALE ST	91352	6	198B165    37	2629008005	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.24038	-118.39922	Installation of new roof mounted solar PV array.  Total system size = 7.2 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1324	13041-20000-09272	6507 W SUNSET BLVD	90028	13	147A187   133	5547017014	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.09815	-118.33133	plan check for fire alarm system. night club.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1325	16041-20000-08619	18751 W RUNNYMEDE ST	91335	3	186B121   497	2118003008	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.20576	-118.54224	Plan check for a PV1 roof-mounted PV system. System size is (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1326	17041-10000-22135	7045 N FARRALONE AVE	91303	3	183B101   215	2024013015	RA-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.19858	-118.61055	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1327	15041-20000-40700	10801 N WINNETKA AVE	91311	12	207B113    70	2707003036	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.26556	-118.5712	PV1.  Install 9.24 kW roof-mounted utility-interactive PV system.  (33) SolarWorld 280W with (1) Fronius-IG Plus A 10.0 central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1328	12041-20000-16379	12301 W WILSHIRE BLVD # 301	90025	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Issued	10/09/2012 12:00:00 AM	ADDRESS	34.04271	-118.46948	New dental office in existing building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1329	16041-20000-23016	3715 S MCCLINTOCK AVE	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.02041	-118.29027	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES IN USC ETHEL PERCY ANDRUS GENRONTOLOGY CENTER. 5490 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1330	17041-10000-05725	352 W 119TH ST	90061	15	084B201  1069	6087020001	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2414.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	33.92455	-118.28007	PC FOR PV SYSTEM ROOF MOUNTED 3KW AC USING 15 MODLES. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1331	17041-10001-01258	8151 N VENTURA CANYON AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.21934	-118.42889	REVISED SINGLE LINE TO SHOW THAT THE TIE-FUSE CONFIGURATION WAS CHANGED TO 1200A NON FUSED SWITCH  AND EXISTING CONDUCTOR((((((((Plan check for power only, new Fuel Cell system rated at 1.6 MW. Fuel cell system is rated at 480 V conncected to 4.16KV (Medium Voltage) distribuition system OSHPD.  Installation on Keiser building connected exterior to OSHPD  4160 V medium voltage service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1332	18041-10000-42301	15976 W ALCIMA AVE	90272	11	129B125   261	4420003017	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Expired	06/02/2024 12:00:00 AM	ADDRESS	34.05093	-118.53477	NO FEES due to AB1414. PC FOR NEW ROOFTOP SOLAR SYSTEM CONSIST OF 24 MODULES (SC325 SOLARCITY STANDARD), 24 OPTIMIZERS (SOLAREDGE P400) AND A CENTRAL INVERTER (SE7600H-US000SNU2). SYSTEM SIZE IS 7.8KWdc and 7.6KWac.PORTION OF THE FEE IS PAID UNDER ONLINE PERMIT #18041-90000-3477. PLANCHECKER TO ADJUST THE FINAL FEE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1333	14041-20001-01338	7732 N RHEA AVE	91335	3	189B121   614	2103019011	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/07/2014 12:00:00 AM	ADDRESS	34.21128	-118.54136	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1334	12041-20000-18077	715 N RIDGEWOOD PL	90038	13	141B189   251	5535002023	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM			Reviewed by Supervisor	09/20/2012 12:00:00 AM	ADDRESS	34.08399	-118.31475	New roof mounted P.V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1335	10041-10000-21158	1526 N EDGEMONT ST 1st Fl-MOB	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	06/27/2011 12:00:00 AM	ADDRESS	34.09898	-118.29599	Alterations of  704 sf of medical office space (BLOOD DRAE AREAS)- installing floor to ceiling partitions and coverting treatment areas to waiting room,reception area and blood draw areas.plan chk is for title 24 and 1ea emergency ckt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1336	14041-10000-33730	3924 N MONTEREY ROAD	90032	14	145-5A229 179	5302033001	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.09233	-118.18912	PV1.  Install 5.1 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.FEE AMOUNT REFLECT ON SENATE 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1337	17041-20000-00838	420 N ROSENELL TER	90026	13	138A205   149	5157014002	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.07199	-118.27092	Plan check for energy only. TI to offices in (E) bank building. New lighting (incl. emergency) and receptacles. 1,787sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1338	19041-20000-05924	20635 W VERCELLI WAY	91326	12	210B109   521	2701051089	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27605	-118.58316	PV1.  Install 8.775 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (27) modules with 5.2 and 3.8 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1339	17041-30000-10884	1050 S GAYLEY AVE	90024	5	132B149   271	4363024021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	34.06115	-118.44706	PC FOR TI 24 ENERGY ONLY OFFICE IN A PARKING STRACTURE. TOTAL AFFECTED AREA OF 129 SQ.FT. SCOPE INCLUDES NEW LIGHT AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1340	17041-10000-10898	555 W 5TH ST 37TH	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	TITLE 24 PLAN CHECK FOR TI(OFFICE SPACE) TO ADD AND REMOVE NON- BEARING PARTITIONS, CEILING, AND FINISHES. TOTAL SQ FT. 7785	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1341	15041-20001-15552	5018 N MEDINA ROAD	91364	3	168B105   166	2168009021	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.15948	-118.59995	expedite per applicant request[[[[Plan check for PV roof mounted 11.4kW system with 46 modules and 1 inverter (11.42kW).]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1342	15041-10000-28641	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022058	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.21384	-118.44905	FULL PC, FOR ENERGY AND POWER ONLY, TO A NEW 6 STORY  GYMNASIUM  & PARKING  (3 LEVELS OF FITNESS CENTER & 3  LEVELS PARKING). UNDERGROUND 2000 AMP SERVICE. TOTAL SQ. FT. 178,876.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1343	12041-20001-19547	14006 W RIVERSIDE DR #265	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			PC Approved	08/29/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Changes to previously approved set of plans. Plan check for energy only. Marbles: the brain store, space 265. 822.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1344	12041-10003-20881	13640 W FOOTHILL BLVD	91342	7	222B157    94	2509014014	(T)(Q)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Info Complete	02/05/2013 12:00:00 AM	ADDRESS	34.3076	-118.43089	Original Plan check only application: 12041-20000-20881. Made the following changes to approved plans: {Decreased total installed wattage from 28,100W to 25,105W. Service size has not changed: 2000A. Total load changed from: 1,350A to:1,506A} Changes are done under delta 1 only, reuce lighting, add kitchen equipment on existing panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1345	13041-20000-08188	8504 W 3RD ST	90048	5	138B173   788	4334009158	C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.07307	-118.3768	Plan check for energy and emergency lighting. Low-rise commercial Ice cream store. Cream Cookie.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1346	14041-10000-17597	13366-13368 W BEACH AVE	90292	11	108B153   847	4230007004	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	33.99152	-118.44357	PC FOR POWER AND ENERGY. NEW 21-UNIT APARTMENT BUILDING. 3 STORIES OVER PARKING AND A COMMUNITY CENTER. TOTAL AREA 11206 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1347	10041-10000-14399	5779 W WILSHIRE BLVD	90036	4	135B177   470	5508015004	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.06261	-118.35433	T.I. to existing restuarant.  Install general/emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1348	10041-10002-04574	1507 S GRANDE VISTA AVE	90023	14	118-5A223 168	5169001002	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM			PC Approved	11/01/2010 12:00:00 AM	ADDRESS	34.01771	-118.21007	revised single line to show that the overhead is relocated  to the diagonal opposite side of the building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1349	15041-20000-02487	18313 W SHEFFIELD LANE PV 1	91326	12	213B125    73	2870019025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.28359	-118.53281	Install roof mounted photovoltaic solar system.  5.56 KW system.  The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FDB) Requirement No. 96.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1350	11041-10000-20659	1419-1427 S ELKGROVE CIR BLDG 10	90291	11	111B149   609	4243002070	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.00077	-118.45815	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1351	15041-10000-04544	800 N HIGHLAND AVE	90038	4	141B185   265	5524004028	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Expired	03/13/2017 12:00:00 AM	ADDRESS	34.08547	-118.33839	Title 24 plan check only.  Total area = 4,327 sq. ft.Replacement of electrical distribution system due to fire damage with new 400 A service.  Changes to lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1352	11041-10001-09464	8500 W BEVERLY BLVD #820	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	07/14/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	REVISIONS TO APPROVED SET OF PLANS-CHANGE THE RTU'S TO LARGER UNITSBUT WITHIN THE 400A RATING OF THE DISTRIBUTION BOARD MDP1)))))))TENANT IMPROVEMENT TO (E) RETAIL SPACE (#820):	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1353	14041-20000-10701	3415 S SEPULVEDA BLVD 8TH FLOOR	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.02055	-118.42347	PLANCHECK FOR T24 ENERGY. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS. OFFICE. 8TH FLOOR.  7376 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1354	12041-20000-16396	10936 W CHALON ROAD	90077	5	141B149    50	4369020001	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.08466	-118.45742	New 800A service, panels, and branch circuits.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1355	06041-10011-23224	6250 W HOLLYWOOD BLVD	90028	13	148-5A189 132	5546029917	[T][Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM	01/29/2010 12:00:00 AM		Permit Finaled	03/15/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	Revisions to approved set of plans- Delta 29- REVISED SERVICE LOAD CALCULATION FOR MAIN SWITCHBOARD MSB-CH AND PANELBOARD CP2TI; UPSIXE CIRCUIT BREAKER IN PANEL MSB-HH ; INCREASED FEEDER TO PANEL H9HSHOH; REVISED LOAD CALCULATION FOR CP2TI; INCLUDE SCHEDULE FOR H9HSHOH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1356	12041-10000-15380	4401 S CRENSHAW BLVD Basement	90043	8	111B185   131	5013013013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	PIN	34.00326739	-118.33207301	Plan check plan check power and energy for T.I. of existing  office space on basement level for MTA Sheriff's Station. Facility not a Critical Operations Power Systems (COPS) per Los Angeles County Sheriff Dept.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1357	11041-10000-11881	1021 S GLENDON AVE	90024	5	132B153  1097	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	06/09/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.062	-118.44436	EXISTING FIRE ALARM WITH 208 DEVICES AND 8 PANELES.  ADDING AN ADDITIONAL PANEL AND 9 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1358	16041-20000-29249	23366 W SATICOY ST	91304	12	189B093   703	2027001048	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Expired	09/28/2018 12:00:00 AM	ADDRESS	34.21077	-118.63635	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1359	18041-10000-19455	4905 E BALTIMORE ST	90042	1	154-5A223  29	5477008031	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1834.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.11929	-118.20944	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15 MODULES (HYUNDAI SOLAR MODULE HIS-S285RG) AND 15 MICROINVERTERS (ENPHASE IQ6-60-2-US). SCOPE INCLUDES NEW LOAD CENTER (125A). SYSTEM SIZE IS 4.275KWdc and 3.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1360	19041-10000-02242	208 W 8TH ST	90014	14	127-5A211 175	5144016058	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	07/01/2020 12:00:00 AM		Permit Finaled	01/09/2024 12:00:00 AM	ADDRESS	34.04313	-118.25392	FULL PLAN CHECK FOR POWER AND ENERGY FOR A TI OF A 12 STORY BUILDING. CHANGE OF USE FROM OFFICE TO 120 RESIDENTIAL DWELLING / HOTEL UNITS WITH RETAIL STORES ON THE 1ST LVL.. SCOPE INCLUDES 2 NEW SERVICES (2000A AND 1000A), 75HP FIRE PUMP, EQUIPMENT AND LIGHTING. TOTAL AFFECTED AREA IS 39833 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1361	11041-20000-27183	170 N CHURCH LANE	90049	11	138B145   284	4429035002	R4-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Expired	01/14/2014 12:00:00 AM	ADDRESS	34.07369	-118.46843	outdoor energy plan check hotel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1362	17041-20000-26627	424 S LINCOLN BLVD	90291	11	111B145   728	4243018007	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.00048	-118.46567	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 3,858 sq. ft.Note: Building application has been generated under 17016-10000-21246	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1363	19041-20000-06616	16300 W VENTURA BLVD	91436	5	168B137   424	2284001062	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	06/10/2020 12:00:00 AM		Permit Finaled	01/16/2021 12:00:00 AM	ADDRESS	34.15674	-118.48819	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first-time tenant. Total lighting area = 2,382 sq. ft.Note: Building application has been generated under 19016-20000-05220	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1364	13041-10001-31125	6801 W HOLLYWOOD BLVD C3-343	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM			PC Info Complete	08/13/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	(((7/15/2014 Changes made to approved set originally plan checked by Francis Ysaguire.  Relocation of lighting and recepticle loads due to modifications of duct locations in new commercial arcade space.)))TENANT IMPROVEMENT FOR A NEW RESTAURANT IN EXISTING SPACES. FULL PLAN CHECK FOR POWER AND ENERGY. NO UNDERGRD WORK. TWO NEW 1200A SERVICE PER APPLICANT. 33779 SQ FT OF ILLUMATED AREA (INDOOR + OUTDOOR).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1365	17041-20000-24091	11490 W CUMPSTON ST	91601	2	174B169  1261	2350010031	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM			PC Info Complete	07/18/2017 12:00:00 AM	ADDRESS	34.1695	-118.38205	new sfd 600 amp service. plan check for power only.  provide units with empty panels branch circuits to be future under separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1366	19041-20000-38930	915 S COCHRAN AVE	90036	4	132B181   523	5089025003	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	34.05834	-118.34879	PV1. INSTALL 5.11 KW DC PV SYSTEM WITH (14) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600A) AND (1) LG ENERGY STORAGE SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1367	17041-20000-39937	7507 N LURLINE AVE	91306	3	186B109   448	2113009004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.20666	-118.58424	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1368	19041-10000-11728	6711 S SEPULVEDA BLVD	90045	11	102B165    39	4110001004	C4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	33.97915	-118.39453	Plan check for a methane detecting system with (15) devices and (1) control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1369	19041-20000-46968	6114 N PASEO LA VISTA	91367	3	177B085   137	2032030043	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.18327	-118.66749	$0 fee per AB1414PV1.  Install 17.11 kW DC / 14.16 kW AC roof mounted grid tied PV system.  (59) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1370	16041-20000-09525	700 S FLOWER ST Ste 2550	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI for commercial office in an (E) highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1371	17041-20000-38135	23029 W SCHOOLCRAFT ST	91307	12	183B097   501	2026013013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.19699	-118.62879	Plan check for solar pv system, roof-mounted array on SFD.Total system size: 11.4kW ungrounded.(1) 11.4kW SolarEdge inverters(32) 325W pv modules.(32) 400W power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1372	19041-20000-19317	1547 N BANNING BLVD	90744	15	036B209   204	7422015006	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	33.7949	-118.25984	PV1.  Install 5.51 kW DC roof mounted grid tied PV system with 9.8 kWh DC-coupled energy storage system.    (19) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1373	13041-10000-35924	1231 S MAPLE AVE	90015	14	124-5A209 199	5145027044	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.03494	-118.25711	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 715 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1374	13041-20000-31894	12833 W NORTH SEAGLASS CIR	90094	11	102B161  1223	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	33.97477	-118.41864	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1375	13041-10000-33090	12942 W WENTWORTH ST	91331	6	195B161   152	2628010021	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.23456	-118.41447	PV1, Roof mounted 5.5 kW DC photovoltaic system using transformerless inverter with power optimizers The following components/equipment are used:(22) Trina solar #TSM-250PA05.18(1) Solaredge #SE5000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1376	13041-10000-30657	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	Building 5 of 5:  SHOTGUN RANGE. INSTALL NEW ELECTRICAL PANELS, NEW CONVENIENCE RECEPTACLES. FEES TO BE VERIFIED BY PLAN CHECKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1377	12041-20000-18391	6033 N CARTWRIGHT AVE	91606	2	177B177   522	2414014006	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.18035	-118.36389	Roof mounted P.V. system with microinverter (8KWdc)and upgrading service to 200 A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1378	17041-10002-02694	3960 S BILL ROBERTSON LANE	90037	9	117A201     1	5037027937	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.01294	-118.28998	10/27/2017Changes include the addition of a Medium Voltage transformer to feed the approved switchboard under the master application. Transformer: 12KV-500KVA***CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 5 ON PLANS. ADDITION OF CUSTOMER OWNED TRANSFORMER ON PLANS AND FEEDER FROM MSVG TO THIS BUILDING. UPDATED SITE PLANS, SINGLE LINE AND ISC VALUES. - SCOPE OF THIS DELTA NOW UNDER SEPARATE PERMIT. APP. WITHDRAWN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1379	12041-10000-04216	950 N HIGHLAND AVE	90038	4	144B185   987	5532013030	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Public Safety Only			02/24/2012 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.08857	-118.33841	New fire alarm system for a commercial BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1380	18041-20000-18468	14845 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29477	-118.45483	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1381	15041-10000-27664	777 S SANTA FE AVE TOWER	90021	14	124-5A217 323	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.03354	-118.23024	RENOVATION OF EXISTING WAREHOUSE CONSISTING OF THREE BUILDINGS. (1) 2 STORY CMU BUILDING(1) 2 STORY ANNEX BUILDING (1) 5 STORY TOWER.COMPLETE REBUILD.  PLAN CHECK FOR POWER AND ENERGY.  THIS APPLICATION TO COVER BUILDING TOWER ONLY.BUILDING APPLICATION UNDER 14016-10001-21080	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1382	15041-10000-11931	9708 W APPALOOSA WAY	91040	7	204B181    87	2549025051	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2015 12:00:00 AM			PC Info Complete	04/21/2015 12:00:00 AM	ADDRESS	34.25862	-118.34248	void	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1383	18041-20000-39703	4208 N ALLOTT AVE	91423	4	165B157   924	2373009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.14616	-118.4281	PV1.  Install roof mounted PV system sized 11.5kW AC interconnected with MSP.$6.59 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1384	17041-20000-42955	931-933 N HIGHLAND AVE	90038	4	144B185  1043	5532012042	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.08802	-118.33877	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,018 sq. ft.Note: Building permit has been issued under 17016-10000-15870	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1385	18041-20000-23582	23901 W WELBY WAY	91307	12	180B089   103	2034002018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.1928	-118.64682	PV1.  Install 9.72 kW AC CEC roof mounted grid tied PV system.  (34) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1386	17041-10000-39193	333 S HOPE ST C-235	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM			PC Approved	10/30/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1387	11041-10000-19409	1521 W FRANCISCO ST Bldgs C&D	90501	15	057B193   154	7351021045	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Public Safety Only			09/13/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	33.8496	-118.30518	INSTALLATION OF SPRINKLER MONITORING SYSTEM WITH CENTRAL STATIONFACP IS LOCATE DIN BUILDING  C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1388	11041-10000-23477	6330 W SAN VICENTE BLVD #100	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM			PC Approved	11/02/2011 12:00:00 AM	ADDRESS	34.06116	-118.36804	tenant improvement adding new outlets and relocating existing lighting in office spaceplan chk is for title 24; permit was obtained through the internet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1389	17041-10000-24408	23373 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.15867	-118.6342	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL/OFFICE TO BEAUTY SALON. SCOPE INCLUDES NEW LIGHTS AND RECPETACLES. TOTAL AFFECTED AREA IS 1540 SQ. FT. B#17016-10000-19875	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1390	17041-10000-19232	5338 N WHITE OAK AVE	91316	5	171B129    31	2257002008	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.16844	-118.51835	PC for T24 only for outdoor lighting. Replacing 13 HID fixtures for new LED lighting. Total area 74400 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1391	11041-10000-15940	7742 N VENTURA CANYON AVE	91402	6	189B157   890	2301013082	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2011 12:00:00 AM	07/29/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.21121	-118.42854	New 7.74 KW roof mounted PV system.  Applicant used standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1392	18041-10000-02873	10250 W SANTA MONICA BLVD # 2375	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Plan check for T24 only for tenant space ""Me Undies"" suite 2375, this scope is for TI portion, core and shell was approved under permit# 17041-10000-40193. Loads are added to the existing panelboard. All other equipments and some lightings are existing."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1393	19041-10000-26730	2470 N GLENDALE BLVD B	90039	13	148-5A209 168	5440002003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.10204	-118.25908	Energy plan check for a barbershop T.I located in a single story building. Scope includes new lighting and equipment with a total lighting area of 791-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1394	19041-10000-25285	11726 W SAN VICENTE BLVD STE 600	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	34.05328	-118.46625	Energy PC for Interior tenant improvement to Suite 600 (1,910 SF).  Scope of work to include interior partitions, finishes, and millwork.  No change in use or occupancy.Building permit # 19016-40000-16917permit fees are coverd under #19041-40000-23497	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1395	16041-20001-20535	1545 W 36TH PL	90018	8	120B193  1362	5041017015	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	34.02197	-118.30445	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 1.75kW with 7 microinverter and 7 modules. Note: Rent control prevent applicant from doing online)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1396	10041-20006-22501	19600 W PLUMMER ST	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			07/13/2012 12:00:00 AM	09/04/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.2426	-118.5602	Changes from previously approved plans.  Change in lighting and some new panels.  Plan check for power and energy.  Note: Approved plans submitted for reference only.*****New 4-stories mixed use building with 402 dwelling units  and retail/commercial areas.  A variance to to separate the electrical and fire alarm/lifesafety system plans and permits was submitted on March 10, 2011.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1397	16041-10001-10267	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Closed	02/13/2018 12:00:00 AM	ADDRESS	34.0631	-118.36086	CHANGE TO APPROVED SET BY CHANGING ALL EQUIPMENT MANUFACTURE AND CALCULATION. (3) NEW DEVICES ADDED.(((PC FOR A NEW METHANE GAS DETECTION SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 1 GAS DETECTION  CONTROL PANEL, AND 129 GAS DETECTION DEVICES.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1398	12041-10000-08560	4465 W MELROSE AVE	90029	13	141B197   470	5538008028	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	ADDRESS	34.08371	-118.2976	New fire alarm system for an existing church with daycare center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1399	15041-10000-02251	12400 W WILSHIRE BLVD	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM			PC Approved	01/26/2015 12:00:00 AM	ADDRESS	34.04157	-118.47031	Plan check for T-24 only total area: 3990 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1400	19041-10002-23931	222 W 109TH PL	90061	8	088-5A203 205	6074014034	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM			PC Info Complete	12/19/2019 12:00:00 AM	ADDRESS	33.93642	-118.27705	"DELTA ""1"" Changes to approved plans for using the existing 100Amp Service equipment instead of ugrading to 200Amp. (((PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 10 MODULES (CANADIAN SOLAR 305), OPTIMIZERS (SEP320) AND A CENTRAL INVERTER (SE3000H-US). SYSTEM SIZE IS 3.05KWdc AND 3KWac)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1401	15041-10001-23168	7557 N GENESTA AVE	91406	6	186B133   260	2203015001	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.20815	-118.50339	Permit was pulled under Express Permit (15041-70000-23168). This is Plan check only per inspector's request.*Using Standrad Plan<Install a roof mounted photovoltaic system to existing single family dwelling  (6.37     KW)Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1402	12041-10004-05668	1340 S FIGUEROA ST	90015	9	126A205    86	5134010016	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			02/20/2014 12:00:00 AM			PC Info Complete	03/17/2014 12:00:00 AM	ADDRESS	34.03951	-118.26852	DELTA REVISION ON PANELS/FEEDERS REGARDING TO PLAN 12041-10000-05668(MEHDI).{{NEW MIXED USE 171 UNIT APARTMENT COMPLEX, 7 STORIES WITH SUBTERRANEAN PARKING. PLAN CHECK POWER AND ENERGY. TWO SERVICES SUPPLYING BUILDING. METHANE ZONE.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1403	17041-20000-44053	23664 W CANDLEWOOD WAY	91307	12	186B093   655	2027013027	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.20246	-118.64328	PV1.  Install roof mounted PV system sized 13.1 kW interconnected with MSP.$13.57 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1404	13041-10000-29837	17735 W PALORA ST	91316	5	168B129   153	2182004066	RE9-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.15967	-118.51987	PV1, ROOF MOUNTED SOLAR INSTALLATION TO INTERCONNECT WITH 200A MAIN SERVICE. SYSTEM SIZE IS 12.528 KW AC. WORK IS DONE ON  A NON-STANDARD MICROINVERTER PLAN. TOTAL OF 58 MODULES (LG; LG260S1C) AND 58 ENPHASE M215.  125A LOAD CENTER. PLAN NOT TO BE EXPEDITED.Senate Bill No.1222 Fee cap reached on original application, thus permit fee is $0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1405	14041-20001-08338	9356 N GEYSER AVE	91324	12	198B121   269	2763017010	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.24078	-118.54236	Expedite fees per applicant request.  (((PV1. Install 4 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US-ZB-U.  16 modules: Canadian Solar CS6P-250PX)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1406	16041-10000-10267	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	12/16/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	PC FOR A NEW METHANE GAS DETECTION SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 1 GAS DETECTION  CONTROL PANEL, AND 129 GAS DETECTION DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1407	19041-10001-09527	9532 N MCLENNAN AVE	91343	12	201B133   596	2686026013	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.24415	-118.50091	EXPEDITED FEES. PV1, NEW ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTERS. (31) MODULES, (2) INVERTERS, 3.0KWAC AND 7.7KWAC. TOTAL SYSTEM SIZE IS 10.7 KWAC, 10.466KWDC, 11.16KWP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1408	10041-10000-17227	9018 N WOODMAN AVE	91331	6	195B153   179	2642031018	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1193.40, 1194.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.23362	-118.4389	UPGRADE SERVICE TO 600A, NEW PANELBOARDS AND CIRCUITS AT  A JACK-IN-BOX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1409	15041-10000-02715	10080 S INTERNATIONAL ROAD	90045	11	090B169    36	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	33.94413	-118.38087	Plan check for Title 24 only. Project is outdoor lighting for a parking lot. Total outdoor lighting area = 40,192 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1410	19041-20000-29510	8317 N KESTER AVE	91402	6	192B149   354	2653023011	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.06	Electrical	Electrical	Apartment			07/30/2019 12:00:00 AM			PC Info Complete	11/13/2019 12:00:00 AM	ADDRESS	34.22218	-118.4576	new apartment building 800 amp service.  plan check for power and energy.  three story, 15 units, all typical unitsbuilding application number 18010-20000-04695	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1411	18041-10000-25695	17424 W VINTAGE ST	91325	12	204B129   538	2734022013	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.25188	-118.5144	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 14 MODULES WITH MICROINVERTERS. TOTAL SYSTEM SIZE 4.27KWDC/ 3.36KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1412	19041-10000-15942	1925 S CENTURY PARK EAST 14TH FL	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI IN OFFICESNEW LIGHTING AND NEW CKTSpLAN CHEK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1413	17041-20000-32780	8360 N ETON AVE	91304	3	192B105   528	2779013022	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Issued	09/21/2017 12:00:00 AM	ADDRESS	34.22124	-118.59493	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (56) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1414	15041-20003-39931	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.23911	-118.3725	[[12/12/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 6 CHANGES TO REMOVE EXHAUST FROM ELECTRICAL ROOM]]]]TI TO RESTROOMS AND ADDITION OF RECEPTACLES IN NORTH/SOUTH SIDE RESTROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1415	12041-10001-21521	685 N SPRING ST	90012	1	133-5A215 166	5408014018	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	PIN	34.05979754	-118.23833413	NOTE CHANGES ON DELTA 4. SCOPE INCLUDES CHANGE OF FIXTURES. ((CHANGE OF USE OF RETAIL SPACE TO DINING AREA OF EXISTING RESTAURANT. EXISTING RESTAURANT OCCUPIES SPACE # H  AND THIS ADDITION OCUPPIES # E,F,AND G.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1416	15041-10002-00256	1060 S HOPE ST	90015	14	127-5A207 254	5139008010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	34.04228	-118.26281	((7/8/2015))CHANGES TO AN APPROVED SET O FPLANS.  CHANGES NOTED RFI 34 AND 36.  CHANGES INCLUDE TRANSFER OF FC CONTROLLER CIRCUIT FROM NORMAL LOAD  FC1ITTO EMERGENCY LOAD SP2.PC for energy and power. T.I. Change of use from manufacture to office in an existing 6 story building.(levels 1 to 6). Total area 59261 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1417	13041-20000-13417	1940 W 65TH PL	90047	8	102B193    62	6016012006	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	33.97972	-118.31255	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW. USING 14 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1418	15041-30001-42252	6226 N COSTELLO AVE	91401	2	177B153   299	2239011019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.18365	-118.43766	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 11.4 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1419	16041-10000-18680	5832 S MCCONNELL AVE	90094	11	102B161  1269	4211037202	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Expired	06/29/2018 12:00:00 AM	ADDRESS	33.97479	-118.41675	NEW F.A. FOR APT. INCLUDING 46 DEVICES 1 PANEL  2 COMM. PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1420	18041-10000-42388	5818 W SANTA MONICA BLVD	90038	13	144B189  1082		C2-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.09057	-118.3163	FULL PC FOR POWER AND ENERGY. CHANGE OF USE  OF A PORTION OF EXISTING SHOPPING CENTER TO MEDICAL OFFICE/RETAIL. SCOPE WILL ALSO CONISIST OF THE COMBINATION OF 3 SUITES INTO ONE AND A TENANT IMPROVEMENT. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3932 SQ. FT. B#18016-10000-33839	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1421	19041-30000-15860	444 S FLOWER ST 13th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is the 13th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 19,438 sq. ft.Note: Building permit has been issued under 19016-10000-10603	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1422	14041-10005-29996	616 S NORMANDIE AVE	90005	10	135B197  1114	5502031011	R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.06287	-118.30017	SUPPLEMENTAL TO APPROVED SET OF PLAN. PC FOR POWER. (10/25/2016). CHANGES IS UNDER DELTA 8, INCLUDES UPGRADING THE GENERAATOR AND CHANGING ATS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1423	13041-20000-22225	23140 W ERWIN ST PV-1	91367	3	177B093   369	2039009011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	09/10/2013 12:00:00 AM	ADDRESS	34.18262	-118.63113	PV-1. Rooftop single family dwelling. Two 6kW and one 4kW for 16kW total AC.  Plan check/permit are for the PV system only, NOT for Main Service upgrade or for derating main breakers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1424	16041-20000-14165	2154 N WILLETTA AVE	90068	4	151-5A187 161	5576016029	RD2-1XL	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.11028	-118.3287	Plan check for a PV1 roof-mounted PV system. System size is 3.5 kWac and consists of (11) AC modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1425	19041-20000-30050	20613 W WOOD ROSE CT	91326	12	219B109   537	2701102027	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.29558	-118.58258	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.725 KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH INTEGRATED MICRO INVERTERS AND A SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1426	17041-10000-19500	10388 N SEPULVEDA BLVD	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	PIN	34.25931857	-118.46630746	"TENANT IMPROVEMENT FOR AN EXISTING RESTAURANT - ""JERSEY MIKE"", PLAN CHECK FOR T-24 (ENERGY) ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1427	11041-10000-17008	510 W 7TH ST	90014	9	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	05/16/2012 12:00:00 AM	ADDRESS	34.04671	-118.25598	TI TO AN EXISTING RETAIL STORE.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1428	19041-10000-05099	3925 W SUNSET BLVD	90029	13	145-5A203 317	5429013030	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.09246	-118.28011	Tenant Improvement to an restaurant. Installing new lights & 600Amp Panel. Plan Check for power & energy. Building Permit: 19016-10000-03988	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1429	19041-20000-00640	5426 N SATSUMA AVE	91601	2	174B173  1347	2416015003	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.16934	-118.36741	Project scope is a change of use from bakery to hydroponic agricultural enterprise in (E) commercial building. No hazardous classification.  Total lighting area = 4,145 sq. ft.  Note: Building permit issued under 17016-20000-21560	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1430	12041-20001-06284	481 N ALMAR AVE PV1	90272	11	126B125   495	4414007002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.04192	-118.5377	Roof mounted P.V. system (4.18 KWdc) with monitoring system.Note: Some P.V. devices permitted under 12041-10000-06284.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1431	19041-20000-07443	330 N FAIRFAX AVE	90036	5	138B177   271	5527037042	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	04/01/2021 12:00:00 AM	ADDRESS	34.077	-118.36127	First-time tenant for commercial office building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1432	14041-20001-04925	1250 N BEL-AIR ROAD	90077	5	147A153   463	4370029011	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.09618	-118.44375	((expedite fees)))pv1 single family dwelling. total system size 17kw ac using transformerless inverters nonstandard plan. total of 78 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1433	14041-20000-11907	14525 W SAN JOSE ST	91345	7	207B149   728	2648019010	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.26157	-118.44946	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. USING STANDARD PLAN. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1434	14041-20000-02142	13132 W CREWE ST	91605	2	183B161   656	2327010013	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.19654	-118.41929	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1435	15041-20000-24318	3740 S WASATCH AVE	90066	11	114B153  1315	4246023018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Expired	08/25/2017 12:00:00 AM	ADDRESS	34.00469	-118.43666	Installation of roof mounted solar PV array.  Total system size = 7 kWac.  Central inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1436	15041-10000-35360	7153 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	33.94244	-118.41906	PC for power, Temporary medium voltage, 4.16KV, from LAWA power trailor #1 to feed Switchgear A and Panel LP4. Switchgear A has three feeders feeding  A-1, A-2 and A-3.  A-1 and A-2 have existing loads and A-3 is for future construction load. Panel LP4 is for power shelter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1437	17041-10000-11971	100 S ORLANDO AVE 1-24	90048	5	138B173   657	5511015003	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			05/02/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.07432	-118.373	Full plan check for a 3 -STORY,  24 UNIT APARTMENT BUILDING OVER 1-STORY PARKING GARAGE. Scope include 1200 Amp underground service, 120/208V 3-phase 4-wire with (8) typical unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1438	14041-20000-14557	1989 N LINDA FLORA DR	90077	5	150B145   186	4377005004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Info Complete	07/01/2014 12:00:00 AM	ADDRESS	34.10649	-118.46632	15.7KW Ground-mounted system with (48) Sunpower modules (SPR-327NE), and  (3) transformer inverters(Sunny Boy SMA SB5000US-12) on a new sub panel load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1439	10041-10000-13831	302 N ALEXANDRIA AVE	90004	13	138B197   288	5520023008	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM			PC Info Complete	07/19/2010 12:00:00 AM	ADDRESS	34.07664	-118.29804	New outdoor lighting. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1440	17041-20000-34460	14325 W JOY DR	91331	6	198B153  1032	2644027244	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24154	-118.44537	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1441	19041-20000-24819	11634 N DELFT LANE pv1	91342	7	213B169  1017	2530001018	(T)RU-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.28218	-118.38424	pv1install roof mounted pv system sized 3.15KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1442	11041-20000-21471	11239 W VENTURA BLVD Ste 103	91604	2	162B173   294	2366035036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/25/2011 12:00:00 AM	ADDRESS	34.14181	-118.37523	T.I.  Existing retail space.  Weight Watchers to be moving in.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1443	19041-10000-52061	3348 N OAK GLEN DR	90068	4	159B181   535	2425026025	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.13047	-118.35158	PLAN CHECK FOR A PV-1 SYSTEM. SYSTEM SIZE 6.93KW. 21 MODULES WITH P400 OPTIMIZERS AND (1) SE7600A-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1444	15041-20000-22579	7604 COURAGE WAY	91405	6	186B145  1160			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20878938	-118.46419293	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1445	15041-10000-30090	889 S FRANCISCO ST	90017	14	129A207   155	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.04769	-118.26404	PC FOR POWER AND ENERGY. T.I. FOR METROPOLIS RESIDENTILS. CHANGES HAS MADE UNDER DELTA  A ON THE ORIGINAL, AND THE NEW WORK AS INDICATED PER PLAN.***PANEL SCHEDULES SHOULD BE UPDATED AND CLEARIFIED THE EXACT AMOUNT LOADS THAT  HAS BEEN CHANGED OR ADDED.PERMIT # FOR CORE AND SHELL 14041-10000-35268.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1446	15041-10000-10402	304 W ORD ST	90012	1	133-5A215 144	5408015003	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.06005	-118.23881	ALTERATIONS TO AN EXISTING RESTAURANT SPACE. PC FOR TITLE 24 ONLY. SQ. FT. 930	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1447	18041-20000-20133	555 S FLOWER ST Floors 8-11	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	PLAN CHECK FOR POWER AND ENERGY FOR TENANT IMPROVEMENT TO (E) OFFICE BLDG. FLOOR 8,9,10,11 (100,425 SF) USING EXISTING DISTRIBUTION EQUIPMENT AND ADDING 1 NEW PANEL TOTAL AFFECTED AREA = 78671 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1448	15041-20000-27374	18770 W WILLOWTREE LANE	91326	12	207B121   574	2728029062	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.26271	-118.54197	Plan check for a PV1 roof-mounted PV system. System size is 9.6 kWac and consists of (2) inverters, (48) modules, (1) load center, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1449	17041-20000-42712	3283 S MOTOR AVE	90034	5	123B161   995	4314022041	C2-1	West Los Angeles	West Los Angeles			2699.04	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.0293	-118.41102	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HEALTH CLUB AND THERAPY ROOMS.  2166 SQFT.NOT A MEDICAL OFFICE PER BULDING PERMIT:  17016-30000-25661	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1450	14041-10002-04643	608 W OLIVER ST	90731	15	018B197   316	7448010038	R2-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM			PC Approved	10/17/2014 12:00:00 AM	ADDRESS	33.74704	-118.29034	Fee is 0.00 due to Senate bill 1222.Change to approved set by adding (2) J-box to the roof-top for module connection.(((PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. 3 KW DC.(13) TRINA TSM-235(13) ENPHASE M215)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1451	18041-10001-09971	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.12626	-118.21412	PLAN CHECK ONLY, SUPPLEMENTAL FOR LOST PLAN REPLACEMENTTHE PROPOSED PROJECT CONSISTS OF non-sales 347 SF OUTDOOR, LATTICE-ROOF LOUNGE AREAPlan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1452	14041-10000-14240	5715 N COLFAX AVE	91607	2	174B169   521	2339010008	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	PIN	34.17446004	-118.3881065	PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH POWER OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1453	17041-10000-05279	1601 E OLYMPIC BLVD	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.02923	-118.24056	PC for Indoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 14,300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1454	19041-10000-35276	200 WORLD WAY T2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Info Complete	09/13/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Full plan check for T2 enhancement delta terminal. Scope includes new lighting and equipment with a total lighting area of 500-SQ FT.FIDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1455	19041-20000-15545	375 N LA CIENEGA BLVD STE 2	90048	5	138B173    80	4337012068	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.07806	-118.37692	T24 ONLY PLAN CHECK FOR EXISTING COMMERCIAL SPACE. SUITE 2 BEING SPLIT INTO TWO ROOMS, ONE FOR RETAIL AND ONE FOR PILATES. TOTAL SQUARE FOOTAGE = 1850SF LIGHTING AND OUTLETS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1456	13041-10000-25587	13135 MIRA MAR DR	91342		225B165    19	2580018***							Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	PIN	34.31120672	-118.40409465	PV1.  Install 6.04 kW AC roof-mounted solar array, interconnect with main service panel.  Microinverter: Enphase M215.  28 modules: REC {REC 250 PE}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1457	10041-20000-25115	8275 W BEVERLY BLVD	90048	5	138B173   394	5514009051	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.07623	-118.36982	Plan check power and energy for new office spaces in existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1458	17041-30000-36669	801 S FIGUEROA ST 9th Floor-Corridor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only in existing space adding lighting fixture in corridor. Total area: 122 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1459	19041-20000-37606	1907 N NOLDEN ST	90041	14	159A229   206	5480029020	RE11-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.12986	-118.19405	PV1. INSTALL 11.34 KW DC SYSTEM WITH (36) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1460	15041-10000-11680	1227 S HI POINT ST	90035	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	PIN	34.02703432	-118.30571354	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1461	18041-20000-49095	16829 W BOLLINGER DR	90272	11	126B121    76	4415011005	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.04474	-118.54632	Plan check for PV roof mounted system, PV System size: 5.85kW DC, 4.97kW AC with 18 PV Modules and 1 inverter(6.0KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1462	13041-10000-18918	1027 W 34TH ST #FLT	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	PIN	34.02400284	-118.2895744	REMODEL LOUNGE/BREAK ROOM IN OFFICE BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1463	16041-10000-42749	17322 W TRAMONTO DR 1-8-Bldg 3	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	01/08/2021 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building 4 story 8 units (Type A) with 1 service 4,000A  feeding all 9 Buildings. Performance method is being use for Title 24. Total area: 14,623 sq ft.Note: This is 9 buildings submit  in 1 plan. 3 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1464	17041-20000-41454	811 E TRACTION AVE	90013	14	127-5A215  44	5163015008	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.0452	-118.23546	Change of use of building portion from office to winery tasting room.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1465	17041-10001-37671	10914 N SHADOW HILLS AVE	91040	7	207B173   497	2528037005	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	9800.21	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM			PC Approved	11/16/2017 12:00:00 AM	ADDRESS	34.26534	-118.36737	EXPEDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 10.58KWAC 12.42 KWDCSCOPE INCLUDES 46 MODULES WITH MICROINVERTERS. PANEL IS CENTERFED VARIANCE FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1466	13041-20000-15958	2023 S PARNELL AVE PV-1	90025	5	129B157   655	4321006036	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.04973	-118.4275	PV-1. Two 6kW inverters for 12kW total. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1467	16041-20000-37797	11547 N BABBITT AVE	91344	12	213B133   500	2607007034	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.28075	-118.50834	pv1install roof mounted pv system sized 6kw interconnected with msp. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1468	19041-10000-20888	8550 N BALBOA BLVD #234	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.22649	-118.5024	PC FOR T24 ENERGY ONLY  FOR INTERIOR TISCOPE INCLUDES NEW CIRCUITS AND LIGHTS.TOTAL AFFECTED AREA 1798 SQ. FTPLAN CHECK ONLY, PERMIT FEES ARE PAID UNDER 19041-10000-20919B#19016-10000-10485	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1469	17041-20000-02665	14436 W RUNNYMEDE ST	91405	2	186B149   456	2215026018	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.20572	-118.44774	Plan check for installation of solar pv array, roof-mounted on a SFD. Interconnect with a 225A MSP.4.8kW ungrounded system. (20) EnPhase M250 microinverters. (20) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1470	12041-10000-14988	1360 S ABBOT KINNEY BLVD	90291	11	108B145  1403	4238004041	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	33.99048	-118.46602	Plan check for energy and emergency lighting. Approx 1600 sqft. Single story commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1471	19041-10000-09040	445 S FIGUEROA ST 2100	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 8,600 SQFT. B#19016-10000-04094	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1472	19041-20000-30069	2459 N HAVERHILL DR	90065	1	153A219   124	5462024037	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.11441	-118.22383	Plan check for PV roof mounted and Energy Stroage system. PV system size: 8.19KW with 26 PV Modules and 1 inverter(7.6KW), 2 Tesla PowerWall 2.0(13.5KWh) 27KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1473	14041-20000-32212	12759 W LOUVRE ST	91331	7	213B161   455	2527027031	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.28078	-118.4109	PV1 SFD. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER. TOTAL OF 14 MODULES. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1474	19041-10000-45612	836 E MANCHESTER AVE	90001	9	097-5A209 277	6042022031	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	33.95994	-118.2593	ENERGY PLAN CHECK ONLY. AREA OF SCOPE (2126)SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1475	14041-20000-30113	11991 N NUGENT DR	91344	12	216B129   178	2601051018	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.28926	-118.5161	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZED 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1476	12041-20001-30407	10261 N GLENOAKS BLVD	91331	7	204B165   134	2537017065	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	11/08/2013 12:00:00 AM	ADDRESS	34.25646	-118.39487	(((CHANGES MADE TO APPROVED SET OF PLANS. CHANGED LOCATION OF PANELS FROM ONE SIDE OF THE ROOF TO THE OTHER.)))))New 113 KW roof mounted PV system for a storage facility.   Also install new 1000A and 800A subpanels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1477	18041-30000-43484	2049 S CENTURY PARK EAST 25TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Expired	12/20/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT RENOVATION OF PUBLIC RESTROOMS ON 25TH FL. NEW LIGHTS WILL CONNECT TO EXISTING BRANCH CIRCUIT SERVING THE AREA. TOTAL AREA: 410 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1478	19041-10000-07214	390 NAVY WAY	90731	15	021B209   251	7440021913	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Issued	03/07/2019 12:00:00 AM	ADDRESS	33.75492	-118.2486	NEW FA SYSTEM IN A 1 FLOOR OFFICE BUILDING CONSISTING OF 1 FACP (12AH x 2), 1 POWER SUPPLY AND 66 DEVICES. (Naval Marine Building)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1479	16041-20000-37755	542 N LARCHMONT BLVD	90004	4	141B189   925	5523017011	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.08023	-118.32348	Plan check for Title 24 only. Project site is a new 2-story office building. Total lighting area = 6,555 sq. ft,Note: Building application has been generated under 16010-10000-03408	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1480	14041-10000-06894	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Public Safety Only			03/14/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.05007	-118.2433	New fire alarm system for a leasing space(first floor, main fire alarm for the bldg will be submitted later.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1481	14041-10000-17213	14332 W OXNARD ST	91401	4	177B153   907	2245017031	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.17924	-118.44545	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 1864 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1482	19041-10000-47216	11166 W GAULT ST	91605	2	183B173   144	2319022003	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	02/11/2022 12:00:00 AM		Permit Finaled	07/19/2023 12:00:00 AM	ADDRESS	34.19925	-118.37459	PERMIT FEE IS $0.00 DUE TO AB1414.PLAN CHECK FOR A NEW ROOF MOUNTED PV2 SYSTEM RATED AT 133KW AC WITH (384) MODULES, (192) OPTIMIZER, TWO CENTERAL INVERTER RATED AT 99.9KW & 33.3 KW, (1) LOAD  CENTER, AND (1) TRANSFORMER BACKFEEDING THROUGH THE UTILITY METER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1483	11041-10000-10528	6530 N LANKERSHIM BLVD	91606	2	180B169   731	2335009022	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM			PC Approved	05/23/2011 12:00:00 AM	ADDRESS	34.18952	-118.38758	TWO TENANT SPACES ( R&S ) CONVERETD TO ONE TENANT SPACEPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1484	17041-10000-26318	5860 S VERMONT AVE	90044	9	108B197  1673	6004001031	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	PIN	33.98790958	-118.29113116	TI TO RETAIL STORE. NEW SPRINT STORE. PC FOR T24 ENERGY ONLY. LIGHTING UPGRADES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1485	10041-10000-00804	777 E 10TH ST 110	90021	9	124-5A211 244	5132002028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			01/15/2010 12:00:00 AM	01/15/2010 12:00:00 AM		Permit Finaled	02/02/2010 12:00:00 AM	ADDRESS	34.03437	-118.24974	First time TI for a retail space.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1486	10041-20001-01201	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM			PC Approved	06/16/2010 12:00:00 AM	ADDRESS	34.21302	-118.45859	Plan check revision Delta 13 to include existing lighting fixtures and remove horn/strobe in room 184 to match field conditions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1487	16041-20000-07270	901 S BROADWAY	90015	14	127-5A209 214	5139003002	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Issued	03/01/2016 12:00:00 AM	ADDRESS	34.04227	-118.25636	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 5,497 sq. ft.Note: Building permit has been pulled under 15016-10000-21691	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1488	18041-10000-44810	604 W 47TH ST	90037	9	112-5A201 328	5018027020	RD2-1	South Los Angeles	South Los Angeles	Voices		2321.20	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.00049	-118.28435	PV1. Install 3.780 kW roof mounted grid tied PV system.  (12) modules with P320 OPTIMIZERS, (1) 3.8 KW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1489	16041-20000-44259	22903 W SYLVAN ST	91367	3	177B097   122	2039007012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.18457	-118.62527	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverters, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1490	17041-20001-41825	11250 W CANTON DR	91604	2	159B173   255	2377014021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM			PC Approved	12/14/2017 12:00:00 AM	ADDRESS	34.13372	-118.37807	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1491	11041-10000-24333	2970 W OLYMPIC BLVD	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	New panels and circuits for an existing commercial space.  Applicant requests a Full-Plan-Check for POWER and ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1492	12041-10000-20216	2100 E PACIFIC COAST HWY	90744	15	033B213    10	7428007009	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	33.79122	-118.23692	INSTALL LIGHTING IN HAZARDOUS AREA.  FCCU OF RTRSORO REFINARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1493	14041-20000-17337	7470 N FIGUEROA ST 3RD-FLOOR	90041	14	162A231    31	5709001014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.13993	-118.18696	PC FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING ONLY.  EXISTING HIGH RISE COMMERCIAL BUILDING.  NEW LIGHTING ALL CIRCUITS ARE EXISTING THIRD FLOOR ONLY.  NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1494	11041-10002-14359	240 E 6TH ST	90014	14	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			01/30/2013 12:00:00 AM			PC Info Complete	03/04/2013 12:00:00 AM	ADDRESS	34.0435	-118.24761	REVISED APPROVED SET OF PLANS: ADDED A FEEDER TO SUPPLY AN EMERGENCY BOARD  250A; AN EMERGENCY GENERATOR WITH A 4-POLE TRANSFER SWITCH FOR EMERGENCY USE ONLY; EXISTING EMERGENCY CIRCUITS WILL BE SUPPLIED FROM THE NEW DISTRIBUTION BOARD. Add a 1-story parking garage over an existing 1 story commercial building.  Also adding an additional 4-story 102 unit apartment buildings (modular built -state-approved apartment units) on top.  Plan check is for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1495	17041-20000-09089	13229-13235 N GLADSTONE AVE	91342	7	225B157   672	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Issued	07/06/2017 12:00:00 AM	ADDRESS	34.3112	-118.42915	Plan check for power only. New 2000A service 'MSB' for (E) commercial building w/4 units. Refeed existing unit panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1496	15041-10000-03998	903 S HILL ST	90015	14	127-5A209 162	5139004022	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.04303	-118.25746	T24 only. remove hid light fixtures and replace with LED fixtures. total area 2152 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1497	11041-10000-10082	3724 E MISSION ROAD	90031	1	136-5A227  61	5211020021	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.06862	-118.20047	new 7-11, TI, power, energy, lighting . all new work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1498	12041-10000-27267	9653 N JUMILLA AVE	91311	12	201B117   520	2761030055	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	04/24/2013 12:00:00 AM	ADDRESS	34.24522	-118.56345	ON ROOF OF SFD, INSTALLATION  OF 3.8KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1499	18041-20000-29475	10880 W WILSHIRE BLVD Ste 700	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.05885	-118.44283	Existing commercial office remodel.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1500	16041-10000-25050	1426 S HAYWORTH AVE	90035	10	129B173   575	5068017016	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			07/18/2016 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.05069	-118.36762	PLAN CHECK FOR POWER AND ENERGY.  NEW 3-STORY, 8-UNIT APARTMENT BUILDING, OVER ONE LEVEL SUBTERANEAN PARKING. 800 A  3PH-4W SERVICE. TOTAL AREA 7,894 SQ.FT. LOCATED ON METHANE ZONE.B# 14010-10000-04170	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1501	14041-10000-05689	2343 N CABOT ST	90031	13	144B213   222	5445030024	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.09299	-118.23976	PV1, INSTALL 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(24) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1502	12041-10000-25676	16640 W HAMLIN ST	91406	6	180B137   542	2231014035	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2012 12:00:00 AM			Plans on Hold	11/09/2012 12:00:00 AM	ADDRESS	34.18828	-118.49606	SINGLE STORY PV1 SOLAR INSTALLATION TRANSFORMERLESS INVERTER 3.2KVA RATING WITH 12 TOTAL MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1503	13041-10000-35512	2307 S THURMAN AVE	90016	10	123B173    54	5064025019	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.03706	-118.36686	PV1, Install 2 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (8) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1504	15041-20000-31590	6525 W SUNSET BLVD 2nd Floor	90028	13	147A187   106	5547017038	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.09815	-118.33187	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 2ND FLOOR ONLY. HIGHRISE. 7086 SQFT. 2008 ENERGY CODE PER ELIE MAALOUF. SUBMITTAL PER APPLICANTS REQUESTBUILDING PERMIT UNDER 06016-10000-11178	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1505	16041-20001-07322	1350 N SAN PABLO ST 1st fl.	90033	14	133-5A225  25	5202005900	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.06068	-118.20361	Revisions to approved set of plans.  Replacement of 400 A switchboard with new 600 A switchboard; additional circuits added to design.  Approval for delta-6, 7, 8 clouded revisions only.  ((((TI) New entrance structure to an (E) 2 story (B-occ) build. Scope of work (Phase I) on the the 1st floor. Upgrade main service to 800A 120/240 3-phase, 4W. Total area: 10,105 sq.ft (indoor) + 559 (outdoor).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1506	13041-20000-15308	15030 W VENTURA BLVD	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	08/15/2013 12:00:00 AM	ADDRESS	34.15272	-118.46063	T24 lighting plan check for remodeled space in existing building.  My fit food. T24 PC ONLY APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1507	14041-10000-10755	1915 N HILLHURST AVE	90027	4	150B197   789	5590012046	[Q]C4-1	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Expired	05/30/2016 12:00:00 AM	ADDRESS	34.10589	-118.28764	Installing a panel, power, and lighting for a tenant.  (Title 24)Total area = 937 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1508	13041-20000-14498	10224 W CHARING CROSS ROAD	90024	5	138B157   124	4359021005	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.07805	-118.42949	RELOCATING 600A SERVICE AND GENERATOR UPGRADE FOR SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1509	18041-10000-03976	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.07157	-118.36014	Energy plan check for an existing starbuck coffee shop TI. Scope includes new lighting and equipment. Total area is 645 SQ FT.NOTE:  ((Inpection to verify that Track lights are used as accent lights and light up walls . )).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1510	19041-10000-40184	937 N CITRUS AVE	90038	4	144B181   680	5532011034	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Issued	11/19/2019 12:00:00 AM	ADDRESS	34.08825	-118.33978	PLANCHECK FOR POWER ONLY. Scope includes replacing a New 1600 service 120/208, 3-phase, (20) new panels, major equipment, and HVAC equipment, replacing all main  feeders with new panels for future use. most of the load is reconnected as existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1511	15041-10000-21820	1337 S HOPE ST	90015	14	126A207   202	5134011024	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.03855	-118.2665	T-24 TO AN (E) PARKING STRUCTURE. SCOPE INCLUDES NEW LIGHTING IN A 5 FLOOR PARKING STRUCTURE.  PC FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQ. FT. 111640.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1512	16041-20000-23177	7900 N BALBOA BLVD Bldg Alpha	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Issued	07/18/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	Plan check for power, hazardous location requirements, and energy. Project site is a row of (9) new portable hangers referred to as the Lima Building. Total lighting area = 17,480 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1513	10041-20000-10080	12744 N SAN FERNANDO ROAD Building 3	91342	7	222B145   396	2506003010	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Public Safety Only			05/27/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	06/03/2010 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for new installation of fire alarm building system for Building 3 & Building 4. FACP located in Building 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1514	14041-20000-35737	4820 N SUNNYSLOPE AVE Bld. 2B	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	12/17/2021 12:00:00 AM	ADDRESS	34.1585	-118.42627	New 3 story apartment building with 23 units.  New 800A service, panels, and branch circuits.  Plan check for power only.Note: Variance to separate fire alarm plans submitted on 12/29/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1515	13041-10002-15329	823 N SEWARD ST	90038	4	141B185   144	5533024029	[Q]MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.08594	-118.33326	CHANGES TO APPROVED: DELTA 2-9. Changes to lighting only. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1516	12041-20001-09325	8930 N VILLAGE AVE	91352	2	195B177   265	2404001006	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley	YES	1021.01, 1021.02	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.23076	-118.35614	Modification to previously approved plan for a fire alarm system.  Added smoke detectors and duct detectors with monitor modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1517	19041-20000-32078	19191 S VERMONT AVE SUITE 1000	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	Plan check for Title 24 only in existing high rise building Tenant Improvement office building. Total area: 17,585 sq ft. B#19016-10000-25569	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1518	10041-10000-05215	800 N ALAMEDA ST Union-Station	90012	14	132A215    65	5409023054	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	05/14/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	ADDRESS	34.05494	-118.23752	TI IN AN EXTING COMMERCIAL SPACE (LA UNION STATION). PLAN CHECK IS FOR TITLE-24 ENERGY CALCS AND EMERGENCY LIGHTS IN THE LOBBY AND STORAGE ROOMS IN THE SOUTH EAST CORNER OF THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1519	14041-10000-17707	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.09783	-118.36466	TI FOR SUBWAY RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1520	14041-10001-33734	8631 W 3RD ST 8631 W 3RD	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	iNSTALLAING (9) 6 INCH led DOWN LIGHTS (2) led WALL SCONCE LIGHTS (2) CEILING SENSORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1521	16041-20001-11128	600 E 4TH ST	90013	14	127-5A215 151	5147010015	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.04421	-118.24072	Revision to approved set - change of emergency source from inverter to unit equipment.  Original approved plans were lost - scope of this application is full plan check for power and energy.  Change of use to banquet hall.  New 800 A service.  Methane zone.  (((Plan check for power and energy. CHANGE OF USE & MAJOR  REMODEL OF (E) MIXED-USE COMMERCIAL (WHAREHOUSE, RESTAURANT&RESIDENTIAL UNITS) TO BANQUET HALL. New 800A service. Project is located in a methane zone.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1522	14041-20000-18532	11201 N RAVENNA LANE	91326	12	210B109   493	2701051063	OS-1XL, [T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.27468	-118.58465	New roof mounted PV system with total system size 6KW .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1523	13041-10000-09274	3718 S WESTSIDE AVE	90018	10	117B185   294	5034001010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00, 2342.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.019	-118.32718	PV1 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 5.232 KW. 16 MODULES AND 1 INVERTER. [INVERTER: POWERONE AURORA PVI-5000-OUTD-US] [MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1524	15041-10000-36834	2045 E VIOLET ST	90021	14	123A217    40	5166014003	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.0327	-118.23071	T-24, Change of use from warehouse to office, TI for corridor, restrooms, a utility room and a office in the core shell area only. TOTAL SQ. FT. 3085 plus 4,740 outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1525	10041-10007-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM			PC Approved	02/27/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	single line diagrams with existing switchboards and distribution boards supplying tenant panel boards at the North Core  Concessions. Review was requested such that Westfield will have knowledge which feeders supply a tenant space. Additional plans will include design and actual loads for each tenant space to be used by the plan checker to verify a panelboard or distribution board is not overloaded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1526	17041-20001-08013	5215 N LUBAO AVE	91364	3	171B113   191	2164005013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM			PC Approved	03/20/2017 12:00:00 AM	ADDRESS	34.16548	-118.56708	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.5 kWac and consists of (42) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1527	13041-10000-13490	1601 W WILSHIRE BLVD	90017	1	132A205   392	5142009035	C2-2, C4-2, R4P-2, R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	34.05562	-118.27024	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ON A STARBUCKS (1820 SQUARE FEET). EXISTING BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1528	14041-20001-26210	16110 W LOS ALIMOS ST	91344	12	207B141   295	2667026002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.26541	-118.48303	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.(40) KYOCERA KD255GX MODULES(40) POWER OPTIMERS(2) SOLAR EDGE SE 5000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1529	10041-10001-19648	1224 S BEVERWIL DR 1ST Flr	90035	5	132A167   219	4330024036	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM			PC Approved	11/22/2010 12:00:00 AM	ADDRESS	34.0554	-118.39891	Changt the priviously approved plan. Change the type of fixture. (((((((((((((((TI ON THE 1ST FLOOR & P1 LEVEL OF AN EXISTING HOTEL.  PLAN CHECK IS FOR POWER & ENERGY.))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1530	15041-20000-29377	21030 W GRESHAM ST BLDG B	91304	3	195B105   139	2779003050	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Apartment			09/04/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.23048	-118.59195	PERMIT FEES $0.00 BY STATE SENATE BILL NO. 1222PLAN CHECKING FOR NEW DESIGN. PV2 COMMERCIAL ROOFTOP SOALR. PC 108 MODULES, 3 CENTRAL INVERTERS AND LOAD CENTERS. PV TO INTERCONNECT TO EXISTING SERVICE. NET METERED. TOTAL SYSTEM SIZE 27KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1531	14041-20000-12489	22925 W ERWIN ST	91367	3	177B097   258	2039013016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Expired	07/08/2016 12:00:00 AM	ADDRESS	34.18296	-118.62633	Roof mounted PV system with Optimizer, and transformerless inverters.  System size 7.65KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1532	16041-10000-35625	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	PIN	33.94094587	-118.40577128	PC FOR POWER. TEMPORATY POWER FOR A CONSTRUCTION SITE (LAX ). SCOPE INCLUDES NEW DISTRIBUTION EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1533	12041-10000-04222	5701 N OAKDALE AVE	91367	3	174B113   212	2153017014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Expired	06/04/2014 12:00:00 AM	ADDRESS	34.17447	-118.56582	single story , SFD, solar on the roof, 10.56 KW. and installation of a sub panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1534	17041-10000-41512	700 S FLOWER ST G620	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			PC Info Complete	11/22/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	First tenant in commercial space- juice barFULL PLAN CHECK';PERMIT OBTAINED ON 17041-90000-29207	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1535	18041-10000-46802	14949 W OXNARD ST	91411	6	177B145   419	2242027009	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.17956	-118.45913	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1536	19041-10002-19550	1546 S EDRIS DR	90035	5	129B165   398	4306013011	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.05105	-118.39739	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS REVISING SINGLE LINE TO INDICATE THE ADDITION OF A PV PERFORMANCE METER. ALL CHANGES CLOUDED UNDER DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1537	18041-10000-45159	4725 S LINDBLADE DR	90230	11	108B161   447	4221008017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	33.9919	-118.41662	Plan check for a 5.2KW AC roofmounted system with (16) modules and (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1538	14041-20000-19246	13570 W BEAVER ST	91342	7	225B157   671	2510020012	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.31186	-118.42836	7.43KW PV1 roof-mounted system with (27) SolarWorld Plus SW275 modules and (1) Power One PVI-6000-OUTD transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1539	19041-10000-10127	634 S SPRING ST	90014	14	127-5A211  51	5144001016	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.04504	-118.25156	REPLACING THE FIRE ALARM CONTROL PANEL (LIKE TO LIKE) OF AN EXISTING FA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1540	11041-20000-23547	11111 W SANTA MONICA BLVD Ste 650	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM			PC Approved	11/03/2011 12:00:00 AM	ADDRESS	34.04771	-118.44481	T.I.  Light fixture remodel to an existing plan check.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1541	13041-20000-23737	11112 W WELBY WAY	91606	2	180B173    31	2319014012	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.1936	-118.37305	PV1 TRANSFOMERLESS SYSTEM. 32 MODULES AND 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1542	13041-20000-34745	22450 W HATTERAS ST	91367	3	174B101    86	2040039007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.17595	-118.61633	PV1 TRANSFORMERLESS SYSTEM. POWER OPTIMIZERS USED. TOTAL SYSTEM SIZE 6.0KWAC. 24 modules and 1 inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1543	18041-10001-19970	12885 W NORTH SEAGLASS CIR	90094										Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	33.9741	-118.42006	**expedited fee per aplicantNew PV1 rooftop Solar system 7.6 kW AC/ 8.125 kW DC with ESS (on separate application#), (25) modules with optimizers, (1) inverter, (1) 200 A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1544	13041-10000-10750	13420 W VAN NUYS BLVD	91331	7	207B157   767	2620007005	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.26363	-118.42505	PLAN CHECK FOR NEW 3-STORY OFFICE BUILDING. 800A 480/277V SERVICE. INDOOR 11,345 SQRFT. EVERYTHING IS NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1545	15041-20000-06070	21820 W BURBANK BLVD Suite 250	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.17228	-118.6032	Plan check for T-24 T.I. office Total area: 1351 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1546	16041-10000-41464	1062 W 251ST ST	90710	15	036B197   174	7413015030	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	33.79659	-118.29487	PC FOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA IS 3525 SQ.FT.THIS APPLICATION IS PC ONLY. PERMIT ALREADY ISSUED SEPARATELY FROM EXPRESS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1547	15041-10000-16639	12499 W OSPREY LANE #1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	33.97883	-118.41112	PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 1 SIZED 1.38KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19518.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1548	10041-10000-21175	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	33.89279	-118.28725	New sprinkler monitoring system. plan check is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1549	18041-10000-42784	8940 W NATIONAL BLVD	90034	5	123B169  1360	4312011034	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.03015	-118.38951	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1550	18041-10000-05417	5801 N CANTALOUPE AVE	91401	2	174B153   286	2246012013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM			Corrections Issued	02/13/2018 12:00:00 AM	ADDRESS	34.17594	-118.43467	PC for PV solar for new 7.2kW(ac) system. Installing 20 AC modules and new 100A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1551	15041-10000-19428	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM			Verifications in Progress	10/16/2015 12:00:00 AM	ADDRESS	33.78054	-118.23195	PROVIDE TEMPORARY POWER FOR TEMPORARY ELEVATORS 13EE-4072 AND 13EE-4073.  HAZARDOUS LOACTION CLASS 1 DIV 2.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1552	16041-20001-36512	9741 N NITA AVE	91311	12	201B101   285	2727007006	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM			PC Approved	11/17/2016 12:00:00 AM	ADDRESS	34.24773	-118.61394	Expedite fee. PV1- INSTALL PV 26 MODULES 6.5kW. (microinverter).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1553	17041-10000-06576	8337 W ANTHONY CIR	90046	4	150A173   248	5567023029	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.10607	-118.37332	PV, INTALLATION OF 2.025 KW DC ROOF-MOUNTED  SOLAR SYSTEM ON A SINGLE FAMILT HOUSE.(7) MODULES: LG # LG315N1C-Z4(1) INVERTER: ABB # PV1-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1554	15041-20000-39576	21770 W LOS ALIMOS ST	91311	12	207B105   135	2722035009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.26598	-118.60334	PV1, roof mounted solar panel, interconnected with 200MSP.  (42)modules: SW285   (42)microinverters: Enphase M250-60-2LL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1555	18041-10000-19213	920 N ADOBE ST	90012	1	135A215     9	5414003014	C2-2D-O	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.06595	-118.24071	NEW LIGHTING AND CIRCUITS FOR  A RE-STRIPED PARKING LOTPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1556	16041-20000-36439	5731 W LEXINGTON AVE	90038	13	144B189   277	5536005006	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			10/14/2016 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	01/27/2021 12:00:00 AM	ADDRESS	34.09288	-118.31469	Plan check for power and energy. Project site is a new 4-story, 9-unit apartment building. Total lighting area = 7,400 sq. ft.Note: Building application has been generated under 16010-10000-04148	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1557	16041-10000-37075	1022 N RIDGEWOOD PL	90038	13	144B189   796	5536017027	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.08952	-118.31448	Installation of new roof mounted solar PV array on existing single family dwelling.  Microinverter system.  Total system size = 3.225 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1558	12041-10001-17282	6701 S CENTER DR 825	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	08/16/2012 12:00:00 AM	PIN	33.97892163	-118.39376065	2400 sq ft tennant improvement to an existing high-rise office building.  Change to lighting, receptacles, and loads.  Load is less than 400A per applicant.  PLAN CHECK ONLY, for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1559	15041-10000-06179	500 W WORLD WAY WEST C5	90045	11	087B165    13	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	PIN	33.9331766	-118.39750919	PC FOR ENERGY ONLY. LAX  DELTA AIR LINE TERMINAL 5 . TOTAL AREA 2125 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1560	16041-20000-41248	5239 N VINELAND AVE	91601	4	171B173   329	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Issued	01/11/2017 12:00:00 AM	ADDRESS	34.16634	-118.37063	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. SALON.Plans expedited - fee paid on submittal 2 fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1561	18041-10000-30728	3019 S WEST VIEW ST	90016	10	120B177   642	5049034038	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			08/14/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.02629	-118.35335	NEW FIRE ALARM SYSTEM WITH 253 DEVICES WITH 9 RPS AND ONE SINGLE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1562	11041-10000-27440	6333 W 3RD ST STALL#112	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM			PC Approved	12/27/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	NEW OUTDOOR LIGHTING FOR STARBUCKS. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1563	15041-20001-12288	6250 N TOPANGA CANYON BLVD # 1587	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	[[[9/28/15  CHANGES TO APPROVED SET OF PLANS. ADDITION OF 2 NEW PANELBOARDS AND DISAGGREGATION OF LOADS. DELTA 1 CHANGES ONLY. ]]]Plan check for 1st time tenant for Go Greek Yogurt & Westfield. Total area: 971 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1564	12041-10000-09675	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010		Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Expired	09/08/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	Plan check for installation of 400HP air compressor. Installation not in hazardous area. (4160V system)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1565	10041-20000-18554	1916-1924 W COLORADO BLVD	90041	14	162A223   106	5686007006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	Commercial			09/20/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.13906	-118.20911	PLAN CHECK POWER AND ENERGY FOR CHANGE USE OF EXISTING AUTO REPAIR FACILITY TO MEDICAL OFFICE NOT PLAN REVIEWED FOR OSHPD III. NEW 600A SERVICE ELECTRICAL SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1566	13041-20000-12838	4438 N ROMERO DR	91356	3	165B117   110	2178021032	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.15108	-118.5565	PV1 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 16.53 KW. 58 MODULES AND 2 INVERTERS. [INVERTER: SUNNY BOY (1) SB6000US (1) SB8000US] [PV MODULE: TRINA SOLAR TSM-285 PC/PA14]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1567	14041-10001-20416	1400 N DEVLIN DR	90069	4	147B169   864	5560037007	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.09595	-118.38641	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY SINGLE FAMILY HOUSE, INTSERCONNECT WITH MAIN SERVICE PANEL.(53) SUNIVA OPT265-60-4-1BO(2) SOLAREDGE INVERTERS: SE6000A-US-ZB-U & SE5000A-US-ZB-U>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1568	16041-20001-36316	715 S MORENO AVE	90049	11	126B141   228	4264007051	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.04297	-118.484	expedite per applicantpv1install roof mounte pv system sized 14kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1569	18041-20002-27441	1710 N MICHELTORENA ST	90026	13	145-5A205 351	5431026013	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Issued	10/09/2018 12:00:00 AM	ADDRESS	34.09182	-118.27293	Revision to approved plans and system redesign.  7.15 kW roof mounted grid tied PV system.  (22) modules total with (1) 7.6 kW rated string inverter. (((PV1.  Install 6.175 kW roof mounted grid tied PV system.  (19) modules with (2) 3.3 kW string inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1570	17041-20001-17592	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.04538	-118.26335	4/3/2018changes to an approved set of plans.  changes noted delta1.  changes include lighting fixture types revised energy calculations.  this is plan check only.  (((Plan check for energy only. New common area lighting (stairs, corridors, etc.) on all levels of existing 5-story (over basement) commercial building. 19,246sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1571	17041-10000-16611	5905 W WILSHIRE BLVD 106 & 107	90036	4	135B177   424	5508016901	PF-1D	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Closed	06/01/2017 12:00:00 AM	ADDRESS	34.06282	-118.35793	PC FOR ENERGY. TENANT IMPROVEMENT TO SUITE BCAM1 AND  INSTALLATION OF TEMPORARY ART EXHIBITION IN EXISTING  GALLERY SPACE , TOTAL CONNECTED LOAD < 400 AMP. TOTAL AREA  670 SQ FT.B# 17016-10000-08009	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1572	17041-10000-29400	10000 W SANTA MONICA BLVD Drive Way	90067	5	135B161    35	4319001001	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	04/22/2018 12:00:00 AM	ADDRESS	34.06351	-118.41446	PC for T24 only for outdoor new drive way lighting. Installing one new circuit. Total area of 22,890 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1573	13041-10000-06489	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	34.03396	-118.24117	NEW FIRE ALARM SYSTEM FOR 4 STORY OFFICE SPACE. 195 DEVICES AND 1 PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1574	16041-10000-17471	1840 S CENTURY PARK EAST 6TH	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	PLAN CHECK FOR ENERGY ONLY. TI REMODEL TO 6 FLOOR (HIGH RISE). TOTAL AREA 14705 SQFT. TOTAL ADDED LOAD LESS THAN 400AMP ADDING NEW LIGHTING AND POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1575	18041-10000-40429	550 S HOPE ST #725	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT SUITE 725 PORTION OF 7TH FLOOR. SCOPE INCLUDES PROVIDING NEW PARTITIONS, FLOORING AND WALL COVERINGS. - TOTAL AFFECTED AREA = 935 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1576	18041-10000-16051	14622 W VENTURA BLVD	91403	4	166-5A151 118	2276002066	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.15125	-118.45177	PC for T-24 only, Change of use and partial interior remodel for a Gym locker rooms. Scope of work includes new circuits and panels. Total sq. ft. 1490.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1577	16041-20000-37972	20133 W VIA CELLINI	91326	12	219B113    28	2701039017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.29398	-118.57182	PV1.  Install 9.64 kW DC roof mounted grid tied PV system.  (33) modules with Enphase S280 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1578	17041-20000-13788	8436 W 3RD ST GROUND FLO-OR	90048	5	138B173   809	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	05/30/2017 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.07301	-118.37448	PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE (E) OFFICE TO RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1579	19041-10000-44053	6600 N NEWCASTLE AVE	91335	3	180B125   442	2122025010	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.19046	-118.52517	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 31  (SUNPOWER 320W) MODULES, 31 (ENPHASE IQ7X) MICROINVERTERS, 1 ENPHASE COMBINER BOX,  125A SUB PANEL, CONNECTED TO A NEW 225A SERVICE. SYSTEM SIZE IS 9.765KW AC AND 9.920KW DC.      MAIN PANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1580	16041-20000-23728	6336 E YORK BLVD	90042	14	153A231   124	5492035001	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Expired	11/13/2018 12:00:00 AM	PIN	34.11425444	-118.18188074	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR TUTORING. "" AMP LOS ANGELES"" 3327 SQFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1581	18041-10000-42791	8940 W NATIONAL BLVD STE F	90034	5	123B169  1360	4312011034	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.03015	-118.38951	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1582	15041-10000-17791	101 S JAPANESE VILLAGE PLAZA MALL	90012	14	129A215   347	5161017022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM			PC Info Complete	11/09/2015 12:00:00 AM	ADDRESS	34.04935	-118.23977	PC FOR POWER AND ENERGY. TI FOR OFFICE. FIRST TIME TENANT. TOTAL AREA 4608 SQ FT.THIS IS PLAN CHECK ONLY.NOTE:  MASTER APPLICATION TO BE UNDER APPLICATION NUMBER 15041-10001-17791	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1583	13041-20000-11116	19343 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.18677	-118.55496	Plan check for energy and emergency lighting only. 1926sqft. Change from restaurant to restaurant. Shaveit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1584	13041-20000-31118	530 S CATALINA ST	90020	10	135B197   887	5502022017	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.06453	-118.29524	PC FOR T24 ENERGY ONLY. LIGHTING IN CORRIDORS FOR COMMON AREA OF HIGH RISE RESIDENTIAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1585	15041-20000-35600	5803 N COLFAX AVE	91607	2	174B169   273	2339013028	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	PIN	34.17596313	-118.38810979	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.0 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1586	14041-10000-26819	5807 S AVALON BLVD	90011	9	108B205  1107	5101006005	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.98959	-118.26538	New fire alarm system in existing commercial space.  74 devices + FACU	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1587	14041-10001-06384	7820 N AMPERE AVE	91605	2	189B161   809	2303014049	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.21255	-118.41781	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 8.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A & PV1-5000-OUTD-S-US-Z-A(34) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1588	17041-10004-12599	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.02557	-118.3665	"DELTA 12 CHANGES TO APPROVED PLANS FOR RELOCATION OF PANEL ""LA1"" & FEEDERS TO AC UNITS WILL BE INCLUDED IN THE FUTURE TI's.<<<<CHANGES TO APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 10 & 11. CHANGES INCLUDE REVISING SERVICE DISTRIBUTION BOARD ON SINGLE LINE DIAGRAM, REVISING ELEVATIONS, ADDING HEAT PUMPS, ADDING TWO PANELBOARDS ""LA1"" & ""LA"", RELOCATING LOADS ON PANEL SCHEDULES, REVISING POWER/LIGHTING FLOOR PLANS, AND REVISING TITLE 24 CALCULATIONS.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1589	16041-10000-36679	10100 W SANTA MONICA BLVD 1600	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 16TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 12453 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1590	13041-10000-36289	17736 W SAN FERNANDO MISSION BLVD	91344	12	210B129   346	2712002004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.27197	-118.52094	PV1, Install 5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (20) Modules: Trina Solar TSM-250PA05.18.(20) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1591	17041-20000-34504	18145 W GRESHAM ST	91325	12	195B125   523	2769017018	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.23107	-118.52893	Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.6kW ungrounded pv system. (19) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1592	14041-20000-26800	20664 W VENTURA BLVD	91364	3	171B109    75	2166013101	(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Issued	09/29/2014 12:00:00 AM	PIN	34.16660198	-118.58290188	TI TO AN EXISTING COMMERCIAL BUILDING 2250 SQFT SINGLE STORY, PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  ADDING LIGHTING TO EXISTING POWER EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1593	19041-20000-21319	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	07/06/2020 12:00:00 AM	ADDRESS	34.09786	-118.29745	Plan check for Health Care Treatment room replace Liberty Linear Accelerator and new lighting in corridor and room area. Total area: 1531 sq ft. B#19016-10000-16454	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1594	18041-10001-07360	707 W WILSHIRE BLVD 3800	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	This is plan check only for T24, permit has been obtained online, permit# 18041-90000-07360. Tentant improvement on (E) office and breakroom space. Total area: 4,770 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1595	18041-30001-02907	10720 W MCCUNE AVE Unit 1	90034	5	117B161   249	4252030005	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.01943	-118.40875	04/19/2018 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from office and garage to office and storage/tenant improvement. Total lighting area = 2,326 sq. ft.Note: Building application has been generated under 17016-30000/30001-37827*****Previous Work Description*****INSTALL 200A 3 PHASE SUB PANEL, (2) 30A CIRCUITS FOR A/C AND (4)  120V AIR HANDLERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1596	16041-20001-05960	5201 W 20TH ST	90016	10	126B177   953	5063001014	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			02/19/2016 12:00:00 AM			Reviewed by Supervisor	03/03/2016 12:00:00 AM	ADDRESS	34.04046	-118.35441	Expedite per applicant request{{{{Plan check for PV roof mounted system on Appartment Building. System size: 3.8kW with 10 modules and 1 inverter(3.8kW)}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1597	14041-10000-07664	4737 N KESTER AVE 1-8	91403	4	168A149    18	2264021018	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Public Safety Only			03/21/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Closed	12/12/2014 12:00:00 AM	ADDRESS	34.15673	-118.45777	NEW FIRE WARNING SYSTEM FOR AN 8-UNITS APT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1598	16041-30000-18518	8358 N CANTALOUPE AVE	91402	6	192B153   597	2637030021	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.22318	-118.43568	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (26) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1599	17041-10000-01868	12621 W SHERMAN WAY PV	91605	2	183B161    14	2324003041	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Issued	06/15/2017 12:00:00 AM	ADDRESS	34.20136	-118.40799	0$ PERMIT FEE DUE TO STATE SENATE BILL 1222PV roof mounted solar system installation on commercial building. (5) Central inverters rated at 36, 36, 36, 28,28 KW each for a total system size of 164 KW, (648) solar modules, 400 amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1600	11041-10000-11484	1788 S LA CIENEGA BLVD	90035	10	126B173   172	5066006011	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	11/02/2011 12:00:00 AM	ADDRESS	34.04498	-118.37655	ALL NEW ELECTRICAL SYSTEM FOR A NEW GROCERY STORE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1601	14041-10000-32794	355 S GRAND AVE	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.05191	-118.2525	Energy plan check for an office IT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1602	13041-10000-25782	1207 N LAS PALMAS AVE	90038	4	144B185  1341	5532004034	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.09291	-118.33647	PV1. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 2.34 kW. TRANSFORMERLESS INVERTER. 6 BENQ MODULES. 1 POWER-ONE AURORA PV1-3.0 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1603	14041-10002-20740	11201 N CHALON ROAD	90049	5	141B145   149	4369009007	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.08239	-118.46048	"DELTA ""6"" CHANGES TO APPROVED PLANS FOR ADDING ONE NEW PANEL ""MHB6"" AND NEW LOADS AND CHANGING SHORT CIRCUIT RATING OF ""MHB2"" TO 22KAIC FULLY RATED ON PAGE E-3.1 ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1604	19041-20000-32963	17655 W PRAIRIE ST	91325	12	198B129   192	2766001020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.2396	-118.51957	PV1. INSTALL 14.07 KW DC / 12.67 KW AC SOLAR SYSTEM WITH (42) LG335N1C MODULES WITH EMPHASE MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1605	10041-10002-19348	12148 W HART ST	91605	2	183B165   274	2321009041		South Valley				1233.01	Electrical	Electrical	Apartment			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.19731	-118.39828	REVISED PERMITTED SET OF PLANS: revised lighting; used different unit equipmentin the corridorsPLAN  check isfor as-built conditionsNew 25 units appartment building. Plan check for power and energy. (Variance for separate fire alarm system has been field.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1606	17041-20000-07718	20725 W SESNON BLVD #248	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Expired	05/05/2024 12:00:00 AM				pv1install roof mounted pv system sized 2.5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1607	15041-20002-18184	20529 W TAMARRON LANE	91326	12	216B109   298	2701083020		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	PIN	34.29206464	-118.58179088	4.18.2016 - Plan check for modifications to approved set. T24 changes only. Change fixtures B, B1, J, S, and X. Update fixture schedule and T24 calculations. Delta 4 changes.====11/23/15: Changes to an approved set, T-24 only. MSB from 200A to 400APermit under 15041-20000-18184====RECREATION BUILDING INCL LOUNGE/ POOL BATH ROOMS/ EQUIPMENT ROOMS/ TRELLIS AND ENTRY TOWERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1608	17041-20004-24776	8500 N BALBOA BLVD SUITE #170	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	"4/20/2018changes to an approved set of plans.  changes to reflect field conditions.  changes include updating feeder tags for xformer LTE.  this is plan check only.  (((3/6/2018changes to an approved set of plans.  changes to include additional panel ""LLP9"" and accessory loads.  plan check for power only.)))  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area of 96,648 sq. ft.Note: Building application has been generated under 17016-10000-15426)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1609	14041-20000-00384	16894 W ENCINO HILLS DR	91436	5	162B133   280	2287016066	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.13734	-118.50111	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 9.5KW AC, 11.03 kW DC. 3 STRINGS FOR 1 INVERTER @ SB7000, AND 1 STRING FOR ANOTHER INVERTER @ SB2500 .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1610	19041-10000-24808	515 S FLOWER ST STE 1125	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	ENERGY PC  FOR TENANT IMPROVEMENT TO (E) OFFICE.  AREA OF SCOPE 2029SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1611	13041-10000-09892	6801 N MAMMOTH AVE	91405	2	183B153  1072	2216024***	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Apartment			04/17/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.19456	-118.43248	New fire alarm control panel to replace an existing fire alarm control panel in a 2-story townhome bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1612	13041-10000-01359	11090 W OPHIR DR	90024	5	135B149   187	4363012001	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			01/17/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.06817	-118.45452	NEW FIRE ALARM SYSTEM INSTALLATION OF 86 DEVICES AND TWO PANELS. FOUR STORY APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1613	17041-10000-24985	11670 N RICASOLI WAY	91326	12	213B109   710	2701076091	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.28431	-118.58413	PC FOR PV SYSTEM USING AC MODULES TYPE. TOTAL OF 18 AC MODULES. SYSTEM RATED 5.7KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1614	14041-20000-08907	739 S GARLAND AVE	90017	1	130-5A207 229	5143009015	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			04/03/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.0508	-118.26704	PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT ON THE FIRST FLOOR ONLY. Service upgrade (400A to 800A). CONVERTING 36 UNITS ON THE FIRST FLOOR.  BUILDING IS APARTMENT HOTEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1615	12041-10001-14929	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Issued	10/04/2012 12:00:00 AM	ADDRESS	34.21585	-118.47965	(( Increase in couple feeder lenths, new two 65 kva 3 phase , three poles, no neutral need all motor loads.  addition of two refrigeration skids, removing two old ref. skids, in exiting one story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1616	14041-20004-17367	7036 N VAN NUYS BLVD	91405	6	183B149   254	2217007018	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM			PC Approved	04/03/2019 12:00:00 AM	ADDRESS	34.1987	-118.44853	04/03/2019 Changes to an approved set of plans. Changes have been made to roof plan to reflect circuit changes, changes to panel schedules to reflect field conditions and load changes, changes to load calculations to reflect updated loads on panel schedules.11/14/2018 Revisions to approved set.  SLD wiring detail changes, relocation of (2) sump pumps to service equipment connection, elevator rating change, relocation of ATS, and relocation of rooftop equipment.  Approval for clouded changes only. [[[8/9/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ARE CLOUDED AND LIMITED TO RELOCATING EMERGENCY GENERATOR FROM ROOF TO OUDOOR ON 1ST FLOOR, USING MC CABLES FOR FLOOR BRANCH CIRCUITS, CHANGING UNIT FEEDER CABLES TO #6 ON SECOND FLOOR UNITS, REDUCING LIGHTING INSIDE UNITS]]]]]]]*****Original Work Description*****Power and energy plan check for 5 stories new built with 132 units assisted  living apartment without kitchens, central kitchen included.  2008 TITLE 24  CODE CYCLE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1617	17041-20000-39096	18411 W CLARK ST Suite 101	91356	3	174B125   488	2160010037	C2-1, P-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.16989	-118.53355	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 3,310sq. ft.Note: Building application has been generated under 17016-20000-28887. Building application has this location as a medical office but tenant space is only being used for speech and physical therapy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1618	11041-10000-05259	3054 W PICO BLVD	90006	10	129B193  1324	5074001006	C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM			PC Approved	03/21/2011 12:00:00 AM	ADDRESS	34.04702	-118.30782	T.I.    NEW OFFICE SPACES.  USED TO BE A CLUB.  NOT ADDING ANY NEW PANNELS.  SINGLE STORY.  1993 SQFT.  WILL DO TITEL 24 PLAN CHECK.  FULL PLAN CHECK MAY BE REQUIRED SUBJECT TO INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1619	18041-10000-48641	5900 W WILSHIRE BLVD 9 & 10TH-FLR	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/24/2018 12:00:00 AM			Reviewed by Supervisor	01/02/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	FULL PC FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR AN OFFICE HIGHRISE BUILDING. TOTAL SQFT 30074. BLD# 18016-10000-40517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1620	18041-10000-06120	20500 W PLUMMER ST	91311	12	198B109    58	2748041001	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.24249	-118.58064	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1621	10041-20000-04068	3435 W WILSHIRE BLVD #141	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM			PC Approved	03/05/2010 12:00:00 AM	ADDRESS	34.06194	-118.29866	Revisions to 10041-10000-00958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1622	12041-10000-23331	8489 W CRESCENT DR	90046	4	153B169   725	5563011022	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2012 12:00:00 AM			Reviewed by Supervisor	10/16/2012 12:00:00 AM	ADDRESS	34.11326	-118.38059	New 5.6 KW roof mounted photovoltaic system for a single family. (11 strings)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1623	13041-10000-20159	5055 W WILSHIRE BLVD 9TH FL	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.06235	-118.34036	13041-10000-20159REMODELING OF EXISTING OFFICES ON THE 9TH FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1624	12041-10001-14759			9	129A209   178	5144020195	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM				REVISED PERMITTED SET OF PLANS TO INCLUDE THE ADDITION OF DATA AND COMMUNICATION OUTLETSNew 22-stories  high-rise mixed-use building with one 4,000 amp service for house/commercial loads(B1,B2, 1ST THRU 4TH FLS and a 3000amp service for residential units ( 290units 5th THRU  22nd FLOORS)-both services are 277V/480V 3PH 4W.  Fees are calculated to match applicants pre-cut check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1625	14041-10000-12917	1127 N CYPRESS AVE	90065	1	145-5A219  55	5454024003	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Expired	06/08/2016 12:00:00 AM	ADDRESS	34.09444	-118.22638	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1626	13041-10001-30926	10055 N WOODLEY AVE	91343	12	204B141   806	2678010012	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.25353	-118.48509	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1627	10041-10000-09100	3633 S LENAWEE AVE Suite 120	90016	10	117B173   620	4204008060	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.0205	-118.37599	T-24 and emergency lighting for office/sales/commercial storage area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1628	17041-20000-04643	14216 W GILMORE ST unit 3	91401	6	180B153   960	2237020009	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.18753	-118.4429	pv2install roof mounted pv system sized 2.5kw interconnected with msp.  This is system 3 of 5.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1629	17041-20000-13420	4476-4480 W ADAMS BLVD	90016	10	123B185   742	5050002019	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.03231	-118.33765	PLANCHECK FOR POWER AND ENERGY. NTERIOR ALTERATION OF EXISTING RETAIL BUILDING AND ADDING SECOND FLOOR. BUILDING PERMIT : 15016-10000-17967	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1630	11041-10000-21688	806 E 3RD ST	90013	14	129A215   316	5163015028	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.04564	-118.23594	ELECTRICAL FOR BATHROOM/KITCHEN REMODEL.  2 OF 3 (11044-10000-11377). Permit previously issued under PCIS 11041-10000-20960 and supplement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1631	15041-20000-36225	300 S GRAND AVE 11 FLR.	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	FULL FLOOR TENANT IMPROVEMENT INCLUDING NON-BEARING PARTITIONS, CEILING, FLOORING, DOORS AND FRAMES, GLASS OFFICE FRONT AND DOORS.PC for Energy only, Total area: 20,971 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1632	12041-10000-14985	1150 W JEFFERSON BLVD	90089	9	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM			PC Approved	06/27/2012 12:00:00 AM	ADDRESS	34.02281	-118.29042	T.I. to an existing pharmacy.  Load is less than 400A per engineer.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1633	11041-20000-20021	10306 S WILMINGTON AVE # 101	90002	15	091-5A215 181	6066001045	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	09/03/2013 12:00:00 AM	ADDRESS	33.94295	-118.23879	laundrymat new tenant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1634	16041-20001-08866	6320 W 85TH ST	90045	11	096B165   394	4108020018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	33.96103	-118.39729	RSES expedited plan check per applicant request.  PV2.  Install 22.3 kW DC roof-mounted PV system.  (3) 6 kW inverters with (72) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1635	10041-10000-15399	7201 S WESTERN AVE	90047	8	102B193  1444	6017001039	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM			PC Approved	08/24/2010 12:00:00 AM	ADDRESS	33.97433	-118.30917	T24 only plan check for remodel of a Jack in The Box restaurant.  Contractor to obtain a permit on a separate application number.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1636	12041-10000-30272	6330 W SAN VICENTE BLVD 101	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	12/26/2012 12:00:00 AM	ADDRESS	34.06116	-118.36804	T24 TI OFFICE HIRISE ON INVERTER. STE 101. METHANE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1637	17041-20000-46596	6263 N TOPANGA CANYON BLVD	91367	3	177B101    20	2146001025	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	07/20/2021 12:00:00 AM	ADDRESS	34.18482	-118.60621	new construction site.  plan check for power.  600 amp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1638	13041-10000-35529	341 S 6TH AVE	90291	11	111B145  1128	4240010015	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	33.99811	-118.47126	PV1, Install 7.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Fronius IG Plus A 7.5. (30) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1639	19041-20000-24014	21901 W ERWIN ST	91367	3	177B105    24	2146029004	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.18301	-118.60425	T24 PLAN CHECK FOR TI WORK IN EXISTING MCDONALDS. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2440 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1640	19041-10000-49397	10720 W CHALON ROAD	90077	5	141B149   146	4362003035	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			Verifications in Progress	04/06/2020 12:00:00 AM	ADDRESS	34.08291	-118.44997	PV1, PLAN CHECK FOR A NEW ROOFTOP SYSTEM, SYSTEM SIZE IS 28.8 KWaC, SCOPE OF WORK IS 80 MODULES (SOLARIA POWERXT-360R-PD) WITH OPTIMZERS (SE P740) LEADING TO TWO CENTRAL INVERTERS (SE14.4KUS) THAT LEADS TO A AC COMBINER BOX, TERMINATING IN A NEW 800A SERVICE. NEW MAIN SERVICE AND SERVICE PANEL TO BE SEPRATELY PERMITTED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1641	19041-10000-52439	22129 W MARTINEZ ST	91364	3	171B101   869	2169022010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.1629	-118.60985	(E-PLAN)NEW INSTALLATION OF 3 ENERGY STORAGE SYSTEMS, 1 PANEL OF 125 AMPS, AND 2 PANELS OF 200 AMPS TO AN EXISTING SOLAR SYSTEM AND SERVICE OF 200 AMPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1642	16041-10000-33868	555 E RAMIREZ ST	90012	14	132A217   238	5409021900	PF-1XL-RIO	Central	Central City North			2060.20	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Issued	09/23/2016 12:00:00 AM	ADDRESS	34.05425	-118.2309	PC for fire alarm IN SINGLE STORY COMMERCIAL BUILDING WITH AN EXISTING FACPSCOPE OF WORK INCLUDES INSTALLING NEW:SMOKE DEDCTORS (16)STROBES (13)AND BATTERY BOOSTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1643	18041-10000-02167	9409 W KINCARDINE AVE	90034	5	123B165   359	4311020011	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.03493	-118.39477	Plan check for installing battery backup system to existing PV roof mounted system and replacing the PV inverter with a new inverter.(1) LG CHEM RESU 10h 9.80KW Battery(1)INVERTER- SOLAREDGE SE7600A-US(240V)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1644	13041-10001-02184	8500 W BEVERLY BLVD # 671	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			PC Approved	04/23/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	((CHANGES MADE TO APPROVED SET OF PLANS. RELOCATED BATHROOM AND REPLACED FIXTURE C3 WITH FIXTURE B1))TI for existing retail space in beverly center mall. Title 24 only and emergency circuit. 2993 sqrft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1645	19041-10000-25616	712 S OLIVE ST 4TH FL	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM			PC Info Complete	09/03/2019 12:00:00 AM	ADDRESS	34.0462	-118.25568	POWER AND ENERGY PLAN CHECK FOR A  FOR A T. I. ON 4TH FLOOR (FIRST TIME TENANT).  SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 14677 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1646	14041-10000-06252	23115 W SATICOY ST	91304	12	186B097   203	2014033024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.2084	-118.63058	PV1.  Install 3.45 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.  Enphase M215-60-2LL.  16 modules: Sun World SW-255 MONO.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1647	13041-10002-20115	1135 N RIVAS CANYON ROAD	90272	11	129B129   182	4409005027	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	34.05074	-118.51584	((((4/21/2015))))  changes to an approved set of plans.  changes marked delta 3 on the plans.  changes include addition of (2) panels and reconnecting existing loads.changes on plan: receptacles for outdoors and lights for illumination of egress and future EV service load calcs. Assumed fault current is 100k per applicant.Most permit fees pulled under combined permit 09010-20000-00871.Inspector requested permit fees for 600A panel and service.pc for power and energy. new (N) SINGLE FAMILY-DWELLING , 2 STORY-HOUSE , SERVICE SIZED AT 600A. ELECTRICAL SERVICE FOR MAIN DWELLING, GUEST HOUSE & POOL HOUSE. not a methane zone.bldg description for 09010 - 20000 - 00871:(P) R3 Occ. Group: +9510 Sqft / 9510 Sqftany subsequent changes require additional fees.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1648	19041-10001-04407	11700 N CORBIN AVE	91326	12	216B113     1	2701002068		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.28162	-118.57177	PLAN CHECK ONLY. DELTA ONE CHANGES TO AN APPROVED SET. CHANGES TO FIXTURE TYPE, VD% CALCULATION, PANELS K AND H, PHOTOMETRICS TO EXCLUDE STREET LIGHTS AND T-24 CALCULATION. NO NEW CIRCUITS. ORIGINAL SCOPE: ((Title 24 plan check.  Installation of private tract site lighting in new development(Tract No 50509).  Lighting area = 395,628 Sq. Ft.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1649	19041-20002-03882	11600 W PICO BLVD	90064	11	123B153   652	4260033045	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Approved	11/04/2019 12:00:00 AM	ADDRESS	34.03227	-118.44393	Revisions to approved set.  Changes made to single line configuration, load calculations, power and lighting plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1650	18041-20000-11615	8020 W ZEUS DR	90046	4	153B173   541	5565019034	RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.11377	-118.37002	Plan check for a PV1 roof-mounted PV system. System size is 14 kWac and consists of (2) inverters, (55) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1651	16041-10000-00936	5549 E ALLAN ST	90032	14	141A239    47	5291020020	PF-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.08119	-118.16063	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.3KWac.(20)MODULES-SE-F270(20)MICROINVERTERS-ENPHASE ENERGY M215-60-2LL-S2X	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1652	14041-10000-15567	4640 W SPERRY ST	90039	13	165B201   172	5593006002	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.14824	-118.27698	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH  NEW FLUORESCENT LIGHT FIXTURES. TOTAL AREA 11200 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1653	18041-10000-29740	424 W PICO BLVD	90015	14	126A207   175	5134017032	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.03913	-118.26523	FIRST TIME TENANT; NEW RESTAURANT. PLAN CHECK FOR POWER & ENERGY.BUILDING PERMIT: 18016-10000-24224	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1654	14041-10002-21086	13031 W JEFFERSON BLVD #300	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	33.97451	-118.42531	plan check only. REVISIONS TO PERMITTED SET OF PLANS: modifying input to ep3ups to accomodate conductors. Changes to pages E0.7, 0.8, and 2.1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1655	12041-10000-27705	8500 W BEVERLY BLVD # 754	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT AT ZZEGNA RETAIL STORE AT THE BEVERLY CENTERPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1656	14041-20001-32848	12180 W MILLENNIUM 1ST FLR-HR	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	"Change to approve set of plan. Replace 6"" recessed luminaires to 4"" -23 watt recessed luminaires. ((((TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING AND CIRCUITS TO NEW PANEL.  TOTAL SQUARE FOOTAGE 2870. PLAN CHECK FOR ENERGY.))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1657	13041-20000-30966	13236 W WEDDINGTON ST	91401	4	171B157   372	2345024006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.16654	-118.42153	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING 22 MODULES. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1658	18041-10001-36214	10250 W SANTA MONICA BLVD space 2480	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, DELTA 4 CHANGES ONLY, SCOPE OF WORK INCLUDES 31 NEW DIMMABLE DRIVERS 0-10V, CHANGES TO T-24 INSTALLED WATTAGE, UPDATE TO LIGHTING FIXTURE SCHEDULE, AND UPDATE TO DRIVER LEGEND.B# 18016-10000-30629	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1659	18041-10000-23716	900 W WILSHIRE BLVD 20TH FLR	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR AN OFFICE SPACE ON THE 20TH FLOOR OF AN EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 21,000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1660	18041-10000-39632	3210 N FIGUEROA ST	90065	1	142-5A221 142	5446018017	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Issued	10/17/2018 12:00:00 AM	ADDRESS	34.08562	-118.2198	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1661	17041-10001-04642	20111 W RINALDI ST BLDG S6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.27542	-118.57218	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding site lighting, replacing exterior lights, revising panel schedules, and revising title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1662	12041-10000-22708	1520 N SAN PABLO ST	90033	14	135A225    64	5202004041	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.0627	-118.20276	Build out shell space, with MRI equipment for an existing medical office building.  Full plan check.  Not checked for OSHPD3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1663	19041-10000-47051	2915 W EXPOSITION PL BLDG # 3	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Closed	06/18/2020 12:00:00 AM				NEW FIRE ALARM SYSTEM IN A NEW 3 STORY TOWNHOMES, 5 UNITS, BLDG #3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1664	14041-20000-08983	21555 W OXNARD ST	91367	3	177B105    33	2146005177	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.17943	-118.59939	Install a new legally required diesel 500KW emergency generator, ATS, and 800A subpanel for Anthem Blue Cross.  No changes in total connected loads.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1665	15041-20003-23492	6817 W FRANKLIN AVE	90068	4	150A185   287	5549018024	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	PIN	34.10444099	-118.33917245	"CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA J.  CHANGES INCLLUDE REVISIONS TO PANELS ""AC"" AND ""CH""  WITH FEEDER REVISIONS.  THIS IS PLAN CHECK ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1666	16041-20001-38637	11117 W SARAH ST	91602	4	168B173   948	2353035016	R1-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.15357	-118.37288	Expedite per applicant request.Plan check for PV system roof-mounted on SFD. 15kW ungrounded system. (59) enphase M250. (59) 290 W PV modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1667	13041-20000-17447	523 W 6TH ST SUITE 1002	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	RENOVATION OF INTERIOR OFFICE SPACE IN EXISTING HIGH RISE. PC FOR T24 ENERGY ONLY. TOTAL AREA 1083 SQ FT. WORK DONE IN SUITE 1002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1668	16041-30000-01084	16252 W NAPA ST	91343	12	192B137    60	2689025007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.22648	-118.48703	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1669	13041-20000-29464	1800 N HIGHLAND AVE 2nd Floor	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.10436	-118.33763	PLAN CHECK FOR T24 ONLY. SCOPE OF WORK ONLY COVERS LIGHTING, RECONNECTING TO EXISTING CIRCUITS. TOTAL SQRFT 9782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1670	17041-20000-39133	135 E 103RD ST	90003	8	091-5A205 407	6063009022	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.9431	-118.27258	PV1.  Install 4.4 kW roof mounted grid tied PV system.  (16) modules with 3.8kW rated string inverter.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1671	16041-20000-27849	21517 W SHERMAN WAY	91303	3	183B105   125	2111018015	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM			PC Approved	08/10/2016 12:00:00 AM	ADDRESS	34.20119	-118.59967	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the addition of a metal storage room. No hazardous locations per applicant. Total lighting area = 1,459 sq. ft.Note: Building permit has been pulled under 14014-20000-02853	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1672	19041-20000-29284	6430 N BELMAR AVE	91335	3	180B117   786	2131027010	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.18766	-118.55812	PV1.  Install 5.44 kW roof mounted grid tied PV system and 9.8 kWh energy storage system.  (17) modules with 5.0 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1673	16041-10000-34563	2211 E WASHINGTON BLVD	90021	14	118-5A217  73	5167019041	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.01911	-118.23271	PC FOR ENERGY ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. INDOOR + OUTDOOR LIGHTING AREA 62207 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1674	17041-10000-18041	15455 W CABRITO ROAD	91406	6	189B145   106	2654039008	M1-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.21708	-118.47008	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - TOTAL OF (29) FIXTURES. TOTAL SQ. FT. 53100	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1675	15041-10000-10965	7933 N AJAY DR	91352	2	189B177   302	2407015012	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			PC Info Complete	04/29/2015 12:00:00 AM	ADDRESS	34.21496	-118.36055	TENANT IMPROVEMENT. PC FOR POWER AND ENERGY TO AN (E) 18,832 SQ. FT. COMMERCIAL OFFICE AND WAREHOUSE BUILDING.refer to permit already issued for this job. permit number 14041-10000-35529PLAN CHECK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1676	16041-20001-03238	11801 W SHELDON ST	91352	6	201B169   102	2537021903	[Q]PF-1XL, [Q]PF-1XL-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM			Not Ready to Issue	03/24/2016 12:00:00 AM	ADDRESS	34.24203	-118.39031	VOID APPLICATION	N	N	Express Permit	06/10/2024 12:00:00 AM
1677	19041-20001-40308	1539 N MURRAY DR	90026	13	144A203   198	5425002007	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.08898	-118.27418	11-14-2019 Changes to an approved set of plan, changes include relocate Energy Storage Devices. All Changes has been clouded. Plan check only, permit fees covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1678	10041-10000-07092	12920 W RUNWAY ROAD	90094	11	102B157   315	4211021030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	07/02/2010 12:00:00 AM		Permit Finaled	06/20/2011 12:00:00 AM	ADDRESS	33.97447	-118.42112	New Methane gas detection system  for a 52-units apartment building, Playa Vista Product 650.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1679	12041-10000-04825	458 S HARTFORD AVE	90017	1	132A207   104	5153023034	CW	Central	Westlake		YES	2091.03	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM			Corrections Issued	03/02/2012 12:00:00 AM	ADDRESS	34.05693	-118.26342	Revise plan to show load side connection in place of line side connection.  The installation shall comply with 690.64(B)(7).  See application 11041-10000-06215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1680	16041-20001-32845	1021 N KAGAWA ST	90272	11	129B129   560	4423010020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.04844	-118.51837	EXPEDITED PER APPLICANTS REQUESTBATTERY STORAGE SYSTEM. + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1681	15041-20001-44027	8436 W FORSYTHE ST	91040	7	207B189   300	2555038009	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	34.26601	-118.31714	Change to approved set of plans, changes include inverter type from Sunny Boy DzmS3800TL-US-22 to Solaredge SE3000A-US with optimizers. {{{{{{Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1682	16041-10000-24677	1836 N SICHEL ST	90031	1	135A223    84	5210013013	R3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.06503	-118.21269	FULL PLAN CHECK FOR A  NEW (4) STORY (27) UNIT AFFORDABLE APARTMENT. 7 TYPICAL UNITS.  1200 AMPS SERVICE 3PHASE 4WIRE 120/208V. TOTAL SQFT = 15000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1683	18041-20001-16578	13445 N GLENOAKS BLVD	91342	7	225B145    79	2501021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Approved	05/24/2018 12:00:00 AM	ADDRESS	34.31638	-118.4614	05-24-2018, Changes to an approved set of plan, Changes include additional lighting, relocate exit signs. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1684	16041-20000-43284	8554 N OWENSMOUTH AVE	91304	3	192B105    80	2779030017	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Issued	12/09/2016 12:00:00 AM	ADDRESS	34.22609	-118.60174	pv1install roof mounted pv system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1685	11041-10000-24817	1057 N VINE ST	90038	4	144B185   814	5533017010	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.09007	-118.32679	new pv system for non profit housing. three stories.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1686	13041-10000-07316	11121 W PENDLETON ST	91352	6	198B173    45	2538011010	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.23852	-118.37336	PLAN CHECK POWER AND ENERGY FOR NEW METAL BUILDING RECYCLING MATERIAL SORTING FACILITY AND TRANSFER STATION. 4000A SERVICE. SITE LOCATED IN METHANE BUFFER ZONE LEVEL II. NO METHANE MITIGATION REQUIRED PER REPORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1687	14041-20002-13379	2768 W FYLER PL	90065	14	159A219    69	5684019020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM			Corrections Issued	06/25/2014 12:00:00 AM	ADDRESS	34.13152	-118.22676	$0 PLAN CHECK FEE DUE TO SENATE BILL 1222 FROM 2012((CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 1.7.5KW PV1 roof-mounted system with (2) Solaredge transformerless inverter model #  SE3800A-US, (30) Renesola modules model # JC250M-24/BB and a Solaredge Power Optimizer model # P300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1688	15041-10000-11069	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM			PC Approved	04/14/2015 12:00:00 AM	ADDRESS	34.07457	-118.37864	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 830.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1689	15041-20000-28562	2167 E 25TH ST	90058	14	117A217    70	5167008031	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.01492	-118.23116	PV2. Install roof mounted PV system sized 22.8 kW. Interconnected with line-side tap at main service panel. (108) Canadian Solar CSP6-260P Modules(2) Solaredge SE11400A Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1690	17041-10002-04963	241 N LAKE ST	90026	13	136-5A205 103	5157018062	R4-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			07/13/2018 12:00:00 AM			PC Approved	07/13/2018 12:00:00 AM	ADDRESS	34.06936	-118.27013	PC FOR CHANGES TO APPROVED SET MARKED UNDER DELTA 4 ONLY. SCOPE INCLUDES REVISION TO LIGHTING CIRCUITS AND EXIT SIGN RELOCATION. THIS IS PLAN CHECK ONLY!PERMIT UNDER MASTER. PC only, Changes to an approved set of plans, note changes on delta 2. Change of service from 1000A to 120/240 3ph, 1200Amp. Tenant switchboard has been change to single phase as well.INCLUDING ADDITIONAL 4 CIRCUITS.  No additional load. ****Plan check for power and energy. New 4 story, 41-unit apartment building, over one level enclosed parking garage and one level basement enclosed parking garage. 1,000A service. T24 area: indoor - 17,980sqft; outdoor - 3,857sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1691	17041-10000-11022	8417 W MELROSE PL C	90069	5	141B173   443	5528002040	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.08377	-118.37377	Plan check for Title 24.  T.I. to retail store.  100 amp subpanel to remain existing with new lighting and receptacles.  Total area = 807 sq. ft.     Building permit #17016-10000-01924	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1692	19041-20000-00486	22209 W DOLOROSA ST	91367	3	174B101   314	2146011015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.17064	-118.61063	Plan check for a PV1 roof-mounted PV system. System size is 14.7 kWdc/11.4 kWac and consists of (1) inverter and (42) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1693	14041-20000-07590	550 S HOPE ST SUITE 300	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	pc for t24 energy only. new lighting in existing tenant. suite 300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1694	19041-20000-41181	12028 N SUSAN DR	91344	12	216B137   267	2609008001	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	02/17/2023 12:00:00 AM	ADDRESS	34.2882	-118.49611	PV1. INSTALL 11.34 KW DC / 10.35 KW AC PV SYSTEM WITH (36) MODULES/OPTIMIZERS (P320) AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1695	19041-20001-11120	23100 W AVENUE SAN LUIS	91364	3	171B097   954	2074020035	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.16191	-118.62958	Expedite per applicant request Plan check for PV roof mounted system, system size:120kW  with 389 PV Module and 4 inverters(30kW) connected to 1200A service supply side tap	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1696	13041-10001-28796	12055 N WOODLEY AVE	91344	12	216B137   198	2605008062	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.28912	-118.48729	][][]EXPEDITED PER APPLICANT REQUEST ][][][PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A 1-STORY HOME. INTERCONNECTING WITH (E) 200A MAIN SERVICE. SYSTEM IS XFORMERLESS, WITH (31) MODULES: TRINA SOLAR #TSM-250PA05.18(1) SOLAREDGE #SE6000A-US(31) SOLAREDGE OPTIMIZERS: POWERBOX, 250W, #OP250-LV-MC4SM-2NA-Z	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1697	16041-20002-24766	10136 W HOLLOW GLEN CIR	90077	5	156B153   152	4382025***	RE15-1-H-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM			PC Approved	09/12/2016 12:00:00 AM	PIN	34.12335252	-118.44234551	[[ 8/19/16 CHANGES TO APPROVED SET. CHANGES TO THE ROOF LAYOUT ]]]]Install a roof-mounted solar array on a SFD. (18) 335W pv modules. MSP is 225A. 6kw Ungrounded system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1698	17041-30000-26134	16019 W SUNSET BLVD	90272	11	129B125   395	4420001001	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.04901	-118.53484	Plan check for Title 24 only in corridor space and restroom of the school. Total area: 2544 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1699	11041-20000-03829	460 S SPRING ST #C	90013	9	129A211   275	5149023***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.04754	-118.24927	T.I. to a high rise building in 1st floor.  Install general/emergency lighting.  Plan check for energy only.Note:  Some electrical devices issued under a separate permit 10041-10000-19409	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1700	16041-10000-16774	1439 W 49TH ST	90062	8	111B193   845	5016021012	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	33.99926	-118.30152	PV1, 12 modules and  enphase M250, 3KW AC system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1701	19041-20000-37067	11211 N SEPULVEDA BLVD lot #20	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 4.09 KW DC ROOF MOUNTED PV SYSTEM WITH (13) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1702	18041-10000-43868	16130 W VENTURA BLVD #120	91436	5	168B141   585	2284003035	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.15632	-118.48496	FULL PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT TO CHANGE OF USE FROM BANK TO MEDICAL FACILITY SUITE 120 (NO SURGERY IS ALLOWED) - SCOPE INCLUDES NEW CONNECTION TO EXISTING 200A 480/277 DISTRIBUTION BOARD, TOTAL NEW CONNECTED LOAD IS APPROX 300A WITH A TOTAL AFFECTED AREA = 2385 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1703	15041-10001-34682	10109 N PARR AVE	91040	7	204B193  1273	2560031008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM			Reviewed by Supervisor	10/26/2015 12:00:00 AM	ADDRESS	34.25283	-118.3133	Expedited plan check per applicant request.  PV1.  Installation of 11.925 kW DC roof-mounted, utility-interactive PV system.   (2) ABB PVI-6000-OUTD-US inverters with (45) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1704	17041-10000-31208	1177 W ADAMS BLVD	90007	8	123A201    18	5055022035	C2-1VL-O, QC1.5-1VL-O, RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.03264	-118.28567	PC for T24 only for replacement of existing outdoor fixtures with LED. Total of 45550sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1705	14041-20000-04832	1309 N LA BREA AVE	90046	4	144B181   105	5548022097	[Q]C2-2D-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	PIN	34.09463172	-118.34444205	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1706	10041-10000-17402	725 S FIGUEROA ST 27TH,28TH-29TH FLRS	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.04886	-118.26071	ALTERATIONS IN THE REST ROOMS ANF VESTIBULES ON EACH OF THREE FLOORSPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1707	10041-10000-00687	1334 E 16TH ST	90021	14	121-5A211 370	5130015006	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Finaled	03/11/2010 12:00:00 AM	ADDRESS	34.0256	-118.24773	Tenant improvement for a commercial building.  Install new 200amp meter,  brnach circuits, general and emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1708	13041-20000-32174	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR T24 ENERGY ONLY. TOTAL AREA 4157 SQ FT. RETAIL. NO CHANGE OF USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1709	15041-10000-41292	2362 N PERU ST	90039	13	147A211   343	5443027006	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.09611	-118.25109	PV1 3.8KW roof-mounted system with (19) Trina Solar TSM-255 modules and (1) ABB PVI-3.8-OUTD inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1710	19041-10002-38456	1515 W 240TH ST	90710	15	042B193   718	7439008032	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	33.8074	-118.30413	change of an aproved set under delta 2 only , change include shifting 1 fixture 4 feet only.Permit fees paid under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1711	17041-10000-01291	12401 W VENTURA BLVD 1-2	91604	2	162B165   190	2367018036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM			PC Info Complete	02/16/2017 12:00:00 AM	ADDRESS	34.14303	-118.40318	PVC FOR ENERGY. T.I. RESTURANT. CONNECTED LOAD <400A. TOTAL AREA394 SQ FT.B # 16016-100000-30922	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1712	19041-10000-53124	150 W 12TH ST	90015	14	126A207   234	5139025028	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	03/20/2020 12:00:00 AM		Permit Finaled	12/06/2020 12:00:00 AM	ADDRESS	34.03831	-118.26077	PLAN CHECK FOR POWER AND ENERGY. FOR EXISTING GYM. SCOPE OF WORK INCLUDES (2) TRANSFORMERS, (2) PANELS, AND CIRCUITS; T24 AREA IS 29,246 SF.****Change of use of a portion of retail on first floor to fitness center.  Interior and exterior remodel of (E) health club / fitness center at basement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1713	10041-20000-18782	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	PIN	34.12750533	-118.21285206	plan check for new fire alarm occidental college bioscience building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1714	10041-20000-08960	12100 W WILSHIRE BLVD 18th fl	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM			PC Approved	05/13/2010 12:00:00 AM	ADDRESS	34.0438	-118.46755	energy plan check lobby and coridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1715	15041-20000-13203	8474 W 3RD ST 103	90048	5	138B173   785	5511032060	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.07314	-118.37566	TI TO EXISTING RESTAURANT. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 2400SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1716	19041-20000-50859	24351 W PHILIPRIMM ST	91367	3	174B089   482	2046010011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.17148	-118.65558	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 15.525 KW DC/14.079 KW AC CEC. SCOPE OF WORK CONSISTS OF (45) PV MODULES WITH OPTIMIZERS, A 125A LOAD CENTER, AND (2) 6 KW INVERTERS. NOTE: FEES $0.00 DUE TO CALIFORNIA SENATE BILL 1222 AND AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1717	17041-20002-14335	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	"02/20/2018 Changes to an approved set of plans. Changes have been made to reflect field installation. Point of interconnection for all systems has been revised. Systems ""B"" and ""H"" have been combined. Location of inverters has changed. *****Previous Work Description*****EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar carports on roof of existing parking structure (Northridge Fashion Center). 825.9kW ungrounded system. (1992) 365W pv modules. Every two modules are connected to a 730W power optimizer."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1718	12041-10000-29651	18587 W CASPIAN CT	91344	12	219B125   158	2601075079	RE20-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	02/04/2013 12:00:00 AM	ADDRESS	34.29736	-118.53809	PV1 9.24 KW ROOF-MOUNT SUNNYBOY7000. 2 STORY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1719	18041-10000-07087	2101 E PACIFIC COAST HWY PROJECT 1	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALL A NEW SUBSTATION #12, RELOCATION OF FIVE EXISTING MOTOR LOADS FROM EXISTING 2.4KV MOTOR CONTROL CENTER (MCC) MCC-9B2 AND RELOCATION OF OUTDOOR MCC-266A7 AND MCC-267B6, PREVIOUSLY INSTALLED IN PROJECT 0.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1720	15041-10001-00558	12499 W OSPREY LANE Bld-16	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/10/2015 12:00:00 AM			PC Approved	08/10/2015 12:00:00 AM	ADDRESS	33.97883	-118.41112	Changes to approved set.  Change of minihorn model to enable low frequency tones.  (((Plan check for new fire alarm system with (1) fire alarm control panel and 40 devices.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1721	10041-10000-25272	1413 N L. RON HUBBARD WAY	90027	13	147B197   870	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM			PC Info Complete	04/01/2011 12:00:00 AM	ADDRESS	34.097	-118.29419	TI for an existing 5 story building. EPC is for power and energy.Permitted and finaled under separate PCIS# (per applicant)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1722	13041-20001-12497	11720 N SEMINOLE CIR	91326	12	213B117    96	2822024010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM			PC Approved	09/04/2013 12:00:00 AM	ADDRESS	34.28307	-118.55901	(((SUPPLEMENTAL APPLICATION. CHANGES TO APPROVED SET OF PLANS. CHANGE INCLUDE 2 CONDUITS TO LOAD CENTER. AND WIRE SIZE CHANGE. CLOUDED.))) PLAN CHECK ONLYPV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 13.520 KW. NEGATIVELY GROUNDED. [SOLAR MODULE: LG260S1C-G3] [INVERTER: (2) SUNNYBOY SB6000US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1723	13041-10005-33753	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR DELTA 5 REVISIONS. CHANGES CLOUDED. REVISED INSTALLED WATTAGE OF FIXTURE LT-04	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1724	10041-20000-23520	888 S FIGUEROA ST 6th fl	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	01/18/2011 12:00:00 AM	ADDRESS	34.0465	-118.26225	energy plan check 6th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1725	15041-10000-07258	1420 W 27TH ST	90007	8	123B197  1342	5054032003	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	34.03029	-118.29223	PV2, INSTALL 15.7 KW AC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE TO MAIN SERVICE PANEL.(64) MODULES ,(3) INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1726	12041-10000-18978	1620 W 182ND ST	90248	15	063B193   237	6108003044	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	33.86545	-118.30656	Plan check for new roof mounted 4.57KW photovoltaic system. Single family dwelling. Permit includes main service panel upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1727	14041-20000-34923	891 S BRONSON AVE	90005	4	132B189   840	5092002019	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Closed	01/24/2017 12:00:00 AM	ADDRESS	34.05634	-118.3209	PV1. Install roof mounted PV system on sfd and detached garage. Interconnected with 225 A msp. System size 8.6 kW.36 275W modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1728	13041-10000-13144	10668 W COHASSET ST	91352	2	186B177   301	2410011042	RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.20653	-118.36345	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A NON STANDARD PLAN. USING POWER OPTIMIZERS. SYSTEM SIZE IS 2.45 KW USING 10 MODULES ON A SINGLE STRING. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: SOLAREDGE # SE3000A-US |||| OPTIMIZER: SOLAREDGE # OP250-LV]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1729	18041-20000-15361	273 N MABERY ROAD	90402	11	123B129   916	4410005001	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.02955	-118.5143	ADDITION OF (2) TESLA POWERWALLS TO ASN EXISTING PV SYSTEM.  PLAN CHECK FOR POWER ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1730	19041-10000-51102	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM			PC Info Complete	12/11/2019 12:00:00 AM	ADDRESS	34.27548	-118.56626	PLAN CHECK FOR TITLE 24; SCOPE OF WORK INCLUDE NEW CIRCUITS AND LIGHTING FIXTURES. TOTAL AFFECTED AREA: 23300 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1731	15041-10001-32988	2448 N ENDICOTT ST	90032	14	139-5A235 289	5217017003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.07566	-118.1724	[PC only] PV 1 rooftop solar installaton(17) 265W modules(1) PVI-3.6-OUTDPermit under 15041-90000-32988	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1732	18041-10000-27663	4011 S CENTRAL AVE	90011	9	115-5A209 249	5114010017	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2283.10	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.01063	-118.25682	NEW SPRINKLER MONITORING SYSTEM WITH 1 PANEL AND 12 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1733	17041-10000-42220	11700 N CORBIN AVE	91326	12	216B113     1	2701002068		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.28162	-118.57177	Title 24 plan check.  Installation of private tract site lighting in new development(Tract No 50509-01).  Lighting area = 138,365 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1734	17041-10000-46477	3217 N EASTERN AVE	90032	14	141A233    26	5213038036	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2014.01	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.08244	-118.17829	INSTALLATION IN NEW TENANT  SPACES PANELBOARDS, CIRCUITS , LIGHTING-ALL MINIMUM ELECTRICAL LOADS   IN ORDER TO SHOW TENANT SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1735	14041-10000-03448	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM			Permit Closed	07/25/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	Methane gas detection.45 control devices with one control panel.Building permit :12010-10000-01270.{{{{{{{Core and Shell permit to construct 65-story, mixed-use high-rise building with 900-room hotel/office tower, over 7-story podium with restaurants, ballrooms, meeting rooms, over 5-level basement garage.  (see permit 12010-10003-01270 for Foundation only permit and permit 12010-10004-01270 for Foundation plus permit)}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1736	15041-10002-12882	21221 W OXNARD ST	91367	3	177B105    59	2149005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM			PC Approved	03/07/2019 12:00:00 AM	ADDRESS	34.17943	-118.59525	"DELTA ""2"", ""3"", ""4"", ""5"" & ""6"" CHANGES TO APPROVED PLANS.Changes include T-24 Lighting, Single Line, most of the unit feeders were reduced from 125A to 100A, ....<<<Six story mixed-use building with 379 dwelling units (including 101 Work-Live units), >>>Building Permit 15010-10000-00387"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1737	19041-10000-30797	2929 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	12/27/2021 12:00:00 AM	ADDRESS	34.10429	-118.24391	PLAN CHECK FOR 800 AMP NEW SERVICE AND PANELS FOR 30 SMALL LOT SUBDIVISION SINGLE FAMILY DWELINGS. (1 OF 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1738	18041-10000-23233	16814 W CALLE BELLEVISTA	90272	11	138B121    26	4431038022	(Q)RD3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.07771	-118.54942	plan check for roof mounted pv system for 13.44kva system using AC modules (X22-360-D-AC) with 42 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1739	17041-10000-08042	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.96577	-118.42406	PC FOR TI TO ENGINEERING SHOP IN LMU. EDUCATIONAL FACILITY. LOAD GREATER THAN 400A. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1740	11041-10000-08487	515 S FIGUEROA ST 19th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			PC Approved	04/27/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	"Ti in an existing office area on the 19th floor in Office of ""Hirschmann Law"". EPC is for T24."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1741	16041-10000-08589	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Closed	02/24/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	PC FOR POWER ONLY ON (E) SPORTS ARENA (CORE & SHELL). SCOPE INCLUDES REPLACING OLD 120/208V DISTRIBUTION EQUIPMENT WITH 1 NEW 480V/277V 3PH 3WIRE 800A DISTRIBUTION BOARD, 4 NEW EMERGENCY PANELS, AND  8 NEW NON-EMERGENCY PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1742	13041-10000-29530	11770 W STONEHENGE LANE	90049	5	150B141    60	4377046023	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	PIN	34.11023837	-118.47697835	PV1.  Install 5 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter w/ power optimizers: Solaredge SE5000A-US.  20 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1743	19041-10002-07527	431 N PASEO MIRAMAR	90272	11	126B117    20	4416001026	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM			PC Approved	07/09/2019 12:00:00 AM	ADDRESS	34.04528	-118.55525	SUPPLEMENT TO AN APPROVED SET, CHANGE MARKED DELTA 1, PV-1 CHANGE INCLUDE CHANGING WIRE FROM JUNCTION BOX TO COMBINER BOX FROM #8 TO #10. EGC CHANGED TO #8 FROM #6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1744	18041-10001-47941	2955 N PASSMORE DR	90068	4	157-5A181 308	2427009018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	ADDRESS	34.12533	-118.35187	**fee expedited per applicant**New rooftop solar system on a SFD, 22.8 kW AC / 23.075kW DC. Install (65) modules, (65) P400 optimizers, (2) central inverter at 11.4 kW each, (1) new 125A solar load center,  (1)  new 400A subpanel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1745	16041-10000-29180	12405 W OXNARD ST	91606	2	177B165   655	2333011018	R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.17956	-118.40334	Plan check for New Fire alarm system for 17 units appartment building Total devices: 105 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1746	16041-10000-15327	1126 W 53RD ST	90037	9	108B197   428	5002025023	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Refund in Progress	09/09/2016 12:00:00 AM	ADDRESS	33.99397	-118.29467	PV1, rooftop solar installation 5kW AC      (18) SUNIVA OPT285-60-4        (1) SE5000A-US    P300 is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1747	19041-20000-44267	13338 W WEDDINGTON ST	91401	4	171B157   398	2344020011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.16656	-118.42382	PV1. INSTALL 8.99 KW DC PV SYSTEM WITH (29) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1748	15041-10002-39284	2727 S BEVERLY DR	90034	5	126B165  1085	4309023027	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.03748	-118.39635	Supplemental permit to 15041-10000-39284: (1) branch circuit for the monitoring system. Permit fee zero dollar per California Senate Bill 1222.****PV1, ROOF MOUNTED SOLAR SYSTEM WITH (45) MODLUES AND (1) INVERTER. TOTAL SIZE 11.4 KW-AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1749	11041-20000-05428	10866 W WILSHIRE BLVD #660	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM			PC Approved	03/18/2011 12:00:00 AM	ADDRESS	34.05907	-118.442	T.I. to existing high rise building.  Install general/emergency lighting partial of 6th floor.  Plan check for energy only.Permit issued under 11041-30000-03789	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1750	19041-10000-35095	12909 W SATICOY ST	91605	2	186B161   433	2303021040	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.20687	-118.41485	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES  -T/24 ONLY  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1751	16041-10001-08743	3745 S COLONIAL AVE	90066	11	114B153  1303	4246023002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	34.0049	-118.43587	PV1. PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.295KWdc / 3.0KWac.(9)MODULES-KYOCERA #KD255GX-LFB3(1)INVERTER-SOLAREDGE SE3000A-US-ZB-UNOTE: SOLAR CLEARANCE & PERMIT PAID UNDER PCIS#16041-90000-08743. ((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling3.0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1752	16041-10000-06539	110 W 11TH ST	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.0392	-118.25858	INSTALL NEW FA SYSTEM FOR AN EXISTING GROUP M/B OCCUPANCY BUILDING. FA IS GENERAL ALARM. 294 FA DEVICES, 6 CONTROL DEVICES AND 1 FA PANEL. PER APPLICANT FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1753	17041-10001-02465	270 S WESTGATE AVE	90049	11	132B145   188	4401004006	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2017 12:00:00 AM			PC Approved	05/10/2017 12:00:00 AM	ADDRESS	34.05824	-118.47125	Expedite per applicant request(((((Plan check for PV roof monted system PV battery back up system. System size: 6kW  and 18 modules, 1 inverter(6.0kW) and Tesla battery (5kW))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1754	12041-20000-11937	2970 W OLYMPIC BLVD #301	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			Plans on Hold	05/25/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	nedical office # 301	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1755	19041-20000-47726	13263 N WHEELER AVE UNIT 10	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1756	13041-20000-19327	8943 N ENFIELD AVE	91325	12	195B129   168	2768005002	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.2333	-118.52466	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 14.4 KW. USING TOTAL OF 50 MODULES. USING ENPHASE MICROINVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1757	19041-10000-38026	10700 N BALBOA BLVD 102	91344	12	207B133   456	2683023020	CR-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	06/15/2020 12:00:00 AM		Permit Finaled	05/26/2023 12:00:00 AM	ADDRESS	34.26494	-118.50209	PLAN CHECK FOR POWER AND ENERGY.  SCOPE INCLUDES  ONE NEW 100A METER SECTION, 1 NEW X-RAY EQUIPMENT, NEW CIRCUITS, AND LIGHTING. ALL ELECTRICAL EQUIPMENT IS FED FROM AN EXISTING 1000A SERVICE. TOTAL AFFECTED AREA IS 10368 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1758	17041-10003-30156	8319 S MAIN ST	90003	9	099B201  1376	6031036029	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2397.02	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	33.96357	-118.27404	Change to approved set by relocating the House panel on floor plan and on the single line; additional minor changes also applied to single line diagram. All changes under delta-3 only.(((DELTA 2 Changes to an approved set of plans dated 6/25/2018. Changes include relocation of service,  addition of 3 new planes and revision of single line diagram, Revisions include change of feeder length, panel name. TI TO EXISTING MULTI TENANT BUILDING. UPDATING SERVICE AND DISTRIBUTION TO RESERVE AND REBUILD TENANTS. REFEED SOME EXISTING LOADS. NEW 800 SERVICE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1759	18041-10000-25229	10718 W ACAMA ST #1-9	91602	2	165B177   956	2423029028	RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.03	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Closed	05/29/2020 12:00:00 AM	ADDRESS	34.1457	-118.36385	PLAN CHECH FOR POWER AND ENERGY FOR (N) 3-STORY 9-UNIT TYPE V-A AFFORDABLE HOUSING. SERVICE SIZE = 1000A AT 120/240V. TOTAL AFFECTED AREA = 11744 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1760	17041-20001-28698	4430 N BALBOA AVE	91316	5	165B133    68	2289016038	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.15179	-118.50478	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD. Interconnect with 400A MSP.11.4kW ungrounded system. (39) 350W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1761	12041-10000-30814	9547 S COMPTON AVE 1-9	90002	15	093A213   192	6048004031	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			12/21/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Expired	01/15/2015 12:00:00 AM	ADDRESS	33.94935	-118.24639	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR 9-UNIT APT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1762	15041-10000-17540	920 S CROCKER ST SUITE 108	90021	14	124-5A211 152	5132002045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.03569	-118.24958	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE PERFORMED IN SUITE 108.  TOTAL SQUARE FOOTAGE 1890.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1763	11041-10001-03229	1240 S MENLO AVE	90006	1	129B197   982	5076019023	C2-1, R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			03/05/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.0479	-118.29052	CHANGES TO PERMITTED SET OF PLANS- FIRE PUMP WAS REMOVED AND THE SECTION REPLACED WITH 400A section to supply new panelboards .New panelboards will have the community center circuits which was supplied from the house panels. 1200A fused disconnect/switch installed to become the main disconnect for the residential distribution board. this enable series rating of the feeder circuit breakers and those of the unit panelboards.NEW 60 UNIT, 4 STORY PLUS 2 LEVELS OF GARAGE BELOW GRADE APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1764	17041-10000-19511	22851 W OXNARD ST	91367	3	177B097   468	2039016007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.1793	-118.62499	PC for rooftop solar for new 7.2 KW system in single family. Using 30 Solaredge CS6K-270W modules with enphase M250 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1765	16041-20001-40571	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	33.76094	-118.29308	[[[4/27/17 CHANGES TO APPROVED SET. PLANCHECK ONLY.  DELTA 3 CHANGES. ADDING NOTE 10 INDICATING CURRENT LIMITER SIZE]]]TI to (E) Target retail store.  Additional display lighting for liquor aisles.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1766	13041-10000-24835	15107 W VANOWEN ST	91405	6	183B145   634	2220020022	R1-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.19408	-118.4625	pc for power and energy. B occupancy - office. Adult education center. Type of construction (shell): type III-B. Not fire-sprinklered. Stories: 1. Total area of this TI : 1743. Total Area/CBC B occupant load: 4448SF/45 occupants. taken from Sheet TS1 architectural pages. New distribution panel 'MRIH', 'MRIL', 'MDP' (MRI main disconnect pre-wired panel), transformer 'TMR' and MRI control panel and MRI. Motors Hp1 and HP2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1767	17041-10002-19527	14845 W VENTURA BLVD	91403	4	168A149   189	2264017026	(T)(Q)C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM			PC Approved	12/24/2018 12:00:00 AM	ADDRESS	34.15238	-118.45654	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES ARE CLOUDED UNDER DELTA X (waiting for designer to clarify delta #). CHANGES INCLUDE REMOVING ONE OF THE ELEVATOR AND COUPLE OF CIRCUITS. PC FOR POWER AND ENERGY FOR NEW GROCERY STORE. NEW 3000A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1768	19041-30000-13853	4203 S REDWOOD AVE	90066	11	108B145  1832	4237003025	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	33.98939	-118.43902	Plan check for Title 24 only. Project site is an existing commercia building. Project scope is a tenant improvement. Total lighting area = 5,376 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1769	15041-10001-32218	11265 N ESKO AVE	91342	7	210B181    50	2550020023	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.2746	-118.34765	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11KW INTERCONNECTED WITH MSP.(38) SUNPOWER SPR327NE-WHT MODULES(2) POWERONE PVI-6000/5000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1770	15041-20000-14896	3223 W 6TH ST 1-96	90020	10	135B197  1267	5502024***	C2-1, PB-1	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.06375	-118.29255	Title 24 plan check only.  Total area = 2,305 sq. ft.  T.I. to existing commercial excersize space.  New step down transformer connected to 3 new panels (<70 A new connected load). New lighting, recepticles, and water heater.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1771	16041-20001-12141	8001 N VENTURA CANYON AVE	91402	6	189B157   306	2213019040	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM			PC Approved	05/08/2017 12:00:00 AM	ADDRESS	34.21649	-118.42885	This supplemental is to divide the pv work into two phases.this pv system is phase 1 of 2this is plan check only fees covered under master application 166041-20000-12141.(((((Plan check for a PV2 carport PV system. System size is 580 kWac and consists of (19) inverters, (2,400) modules, and (2) load centers.)))))Note: Building application has been generated under 16010-20000-01407	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1772	17041-10001-45297	1001 W KNOX ST	90502	15	057B197    18	7351031017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Closed	05/17/2019 12:00:00 AM	ADDRESS	33.85434	-118.29392	"Chnages to an approved set of plans. Changes include revising load calculations for panels ""H2"" and load calculations for ""MSB"".  Changes to reflect as built."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1773	18041-20001-45196	5011 N DEL MORENO DR	91364	3	171B113   530	2166044009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.16106	-118.57635	Expedite per applicant requestPlan check for PV roof mounted system, system size: 12.54kW DC, 10.65kW AC wtih 38 PV modules and 1 inverter(11.4kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1774	19041-20000-53219	14431 W BURBANK BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			PC Info Complete	06/25/2020 12:00:00 AM	ADDRESS	34.17235	-118.44762	Plan check for Title 24 Energy only, new lighting indoor area. Total area: 1185 sq ft. B#19041-20000-40891	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1775	19041-10000-32508	20101 S HAMILTON AVE 1ST &3RD-FLR	90502	15	054B197   127	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	33.84769	-118.28637	POWER AND ENERGY PLAN CHECK FOR AN INTERIOR TENANT IMPROVEMENT OF EXISTING OFFICE SPACE (1ST & 3RD FLOOR). SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLE AND CONTROLS. TOTAL NEW CONNECTED LOAD GREATER THAT 400A. TOTAL AFFECTED AREA IS 35470 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1776	17041-10000-15748	13784 N DE GARMO AVE	91342	7	228B145   110	2603021027	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.32241	-118.47141	PV INSTALLATION OF A NEW 5KW AC ROOF-OUNTED  SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(18) MODULES: SUNMODULES SW 290 MONO BLACK(1) INVERTER: SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1777	18041-10000-11515	2303 W MIRAMAR ST	90057	13	135A205    95	5154012035	R3-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.06496	-118.27405	REPLACE INDOOR/OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1778	19041-10001-47408	6050 W JEFFERSON BLVD	90016	10	117B169     7	4204008011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		7025.02	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Issued	11/20/2019 12:00:00 AM	ADDRESS	34.02066	-118.38059	change to an approved set adding 3 duct dectors , 3 relays and 3 LED Lights. change the panel model.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1779	13041-10000-26710	14610 W CHASE ST bldg D	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Info Complete	03/19/2014 12:00:00 AM	ADDRESS	34.22458	-118.45089	Core and shell for 1-story type V-B retail and restaurant.  11,349 sq ft.  BLDG D on submitted electrical plan set. Tenants to have their own plan check and permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1780	18041-20000-04501	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	33.79072	-118.29449	"one for one replacement of 300kw generator and (2) ATS refeeding distribution board ""ESAA"" and ""1EA"".no change in loads."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1781	15041-20000-28666	3150 W WILSHIRE BLVD # 200	90010	10	132B197   112	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.06163	-118.29086	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT PER APPLICANT. YOGA STUDIO - ON 2ND FLOOR. SUITE I	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1782	17041-10000-44204	8750 S VERMONT AVE	90044	8	096A199   110	6038010904	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	33.95806	-118.29132	PC for power and energy for 21 unit apartment 5 storie building with two levels of commercial. Installing new 3000A 208/120V service with three distribution boards, new panels, equipment and circuits. B#17010-10000-02540. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1783	16041-20000-41230	17963 W INGOMAR ST	91335	12	189B129   950	2101025007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.21252	-118.52501	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1784	18041-20000-07794	20651 W CHESTNUT CIR (#264)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29368	-118.5843	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1785	11041-10000-20630	1118-1120 E LAKE ST BLDG 25	90291	11	111B145   161	4243001039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.00361	-118.45925	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1786	16041-20000-06880	13800 W VALERIO ST	91405	2	186B153   473	2216038025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.20466	-118.43373	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (10) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1787	14041-10000-22992	1116 S CROCKER ST	90021	14	124-5A211 287	5132010059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.03357	-118.25111	T24, replace HID light fixtures with new LED fixtures. Total area 2640 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1788	16041-10000-09563	839 N COOPER AVE	90042	14	156A233   236	5716011004	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM			Reviewed by Supervisor	04/28/2016 12:00:00 AM	ADDRESS	34.1217	-118.17446	PV1 roof mounted solar system to a single family home. Inverter size: 6.0 kw, 24 solar modules/optimizers. submitted by customer request ( No standard plan )	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1789	18041-10000-19517	6455 N COLDWATER CANYON AVE	91606	2	180B161   919	2326016001	[Q]C1-1VL, [Q]P-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.18831	-118.41404	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1790	15041-20000-33018	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.07594	-118.35916	Plan check for Guards Booth Title 24. Total area: 45 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1791	16041-10000-42713	7029 N ORION AVE	91406	6	183B145   259	2222035025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Issued	12/06/2016 12:00:00 AM	ADDRESS	34.19844	-118.47069	PV1 roof mounted solar system installation to a single family home. Installing (35) Microinverters rated at 327 watts each for a total system size of 11.445 Kw	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1792	16041-20000-44551	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	33.79072	-118.29449	Retrofit and replacement of existing fluorescent lights with LED lights in public areas of a lowrise medical office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1793	16041-20000-08618	337 W 45TH ST	90037	9	112-5A203 110	5110003016	RD2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.00299	-118.2796	Install a roof-mounted solar array on a single unit of a 3-unit property.System size: 3.6kW. Ungrounded system. (13) 285W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1794	18041-10000-34500	1900 S AVENUE OF THE STARS SUITE #125	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI FOR AN EMPLOYEE BREAKROOM IN A EXISTING OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1795	15041-10000-40578	1505 N EDGEMONT ST	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.09843	-118.29637	TENANT IMPROVEMENT TO EXISTING ENTIRE 3RD FLOOR WITH NEW OFFICES, TOILET ROOMS, CONSULTATION GROUP ROOMS, RECEPTION.  NEW BEARING WALL, CEILING, MILLWORK, OPERABLE WALLS AND FINISHES.pc for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1796	17041-10001-12602	7330 N FIGUEROA ST	90041	14	162A231   184	5709006005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.13696	-118.1878	SUPPLEMENTAL FOR T24. INSTALLING NEW 400A SERVICE AND SERVICE EQUIPMENT AND RECONNECTING PANELS. LOAD UNDER 400A. ALL CHANGES CLOUDED UNDER DELTA 3 AND 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1797	14041-20000-16146	5653 W VIRGINIA AVE	90038	13	144B193   527	5536007032	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.0919	-118.31276	PV1Microinverter Standard plan.Install roof-mounted solar array on SFD. System size: 9.5kW(38) EnPhase M215 micro-inverters(38) Canadian Solar CS6P-250P pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1798	10041-20000-00465	6600 N TOPANGA CANYON BLVD #2006	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/20/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	Master CutsRequest for Modification to separate Fire Alarm system filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1799	10041-20000-20954	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM			PC Info Complete	02/03/2011 12:00:00 AM	ADDRESS	33.78808	-118.29535	Per applicant request. Plan check for Kaiser 30KVA UPS LAN upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1800	16041-10000-02834	1253 E 58TH ST	90011	9	108B209  1255	5104026031	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	33.99029	-118.25287	PV1, rooftop solar installation 3.655 kW AC. (17) modules and microinverters M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1801	12041-20003-27401	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	PIN	34.03245819	-118.45766562	SUPPLEMTAL APPLICATION TO CHANGE EQUIPMENT GROUND CONDUCTOR TO 700MCM IN EACH SET OF PARALLEL CONDUCTORS.Relocation of distribution equipment to inside 12333 W. Olympic. Refer to 12041-10000-27401 for core and shell. Build out on 13041-20000-06945.INSTALL A NEW 277/480V, 3ph, 4W, 5,000 AMP SERVICE FOR TWO NEW BUILDINGS (PARKING STRUCTURE AND BUILDING #4).  THERE ARE NO CONNECTED LOAD AT THIS TIME. ALL FUTURE TI's REQUIRE COMPLETE ELECTRICAL PLAN CHECK AND PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1802	16041-20001-40088	13456 W BEACH AVE	90292	11	108B149  1178	4230004008	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	33.99047	-118.4457	Plan check for energy only. TI to existing office. New lighting (incl. emergency) and receptacles.3,450sqft. Supplemental permit for additional fees. Original permit was pulled under parent application #16041-20000-40088.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1803	15041-20000-08655	1530 W 82ND ST	90047	8	099B193  1314	6034014006	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	33.96447	-118.30357	Installation of new roof mounted solar PV array.  Total system size = 4.3 kWac.  Microinverter system with 2 branch circuits.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1804	13041-10000-33133	1332 S SANTEE ST	90015	14	124-5A209 255	5133018015	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.03428	-118.25881	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 1950 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1805	15041-20000-19859	11200 N CORBIN AVE	91326	12	210B117   384	2701040027	(Q)C1.5-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM			PC Approved	06/24/2015 12:00:00 AM	ADDRESS	34.27517	-118.5618	Plan check for Title 24 only Medical Office Building. No work in patient area.  Relocated lighting in the corridor. Total area: 250SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1806	13041-10000-12631	2472 N LYRIC AVE	90027	4	150B201   889	5433020027	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.10614	-118.27683	PV1, 1 story house.  Install roofmounted solar array, interconnect with main panel.  2.4 KW DC system size.  {Transformerless inverter: SolarEdge SE5000A-US} {18 modules: TSM-240 PA05}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1807	14041-20000-14626	3114 N MINNESOTA ST	90031	1	139-5A223 105	5208001030	[Q]RD3-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.0775	-118.20848	pv1 single family. total system size 3.4kw ac using 16 modules. using microinverter enphase m215. using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1808	13041-10000-04605	2401 W JEFFERSON BLVD	90018	10	120B189   644	5052001037	C2-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10, 2190.20	Electrical	Electrical	Apartment			02/22/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.02575	-118.3214	New fire alarm system for 4 story apartment. 181 devices with 1 fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1809	12041-10000-03838	512 W 6TH ST	90014	14	129A209    96	5144004037	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM			PC Approved	02/21/2012 12:00:00 AM	ADDRESS	34.04816	-118.25473	"INTERIOR TENENANT IMPROVEMENT TO EXISTING RESTAURANT ON THE FIRST FLOOR AND CONVERT E XISTING OFFICE /STORAGE  MEZZANINE AREA TO FOOD PREP. AREA AND STORAGE FOR FIRST FLOOR RESTAURANT USE.  ""NO COOKING EQUIPMENT""PLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1810	17041-10000-20497	10406 N SEPULVEDA BLVD	91345	7	207B145   771	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Closed	08/17/2018 12:00:00 AM	ADDRESS	34.25951	-118.46706	full plan check for a  retail space located on the 1st floor of a commercial building. Total area is 1632 SQ ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1811	14041-20012-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			06/19/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	33.95713	-118.3847	6-19-2019 Changes to approved set of plans.  Changes include addition of cove lighting to the parking level elevator lobbies and removal of L13 fixtures from ground floor lobby.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1812	13041-10000-34538	3833 W 6TH ST	90020	10	135B193   857	5503021023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.06367	-118.30637	T24 PART 6 ENERGY LIGHTING WORK FOR EXISTING SINGLE STORY RESTAURANT, WITH MEZZANINE./ ('KYCHOCHON CHICKEN') ; LIGHTING REMODELING IN SCOPE OF WORK IS 1400 SQ FT , INDOOR. WORK INCLUDES EMERGENCY LIGHTING. E-PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER. SCOPE OF WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1813	19041-20000-29134	5901 W CENTURY BLVD ste 1040	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Issued	07/29/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	ti to an exisitng commercial building (high rise) adding new lighting new controls to existing panels.  plan check fot indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1814	14041-20000-27418	6430 W SUNSET BLVD	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.09782	-118.32979	Fire alarm system replacement: addition of 445 (N) notification and initiating devices, and (2) new control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1815	15041-10000-01632	11345 W PENROSE ST	91352	6	192B173   266	2632007013	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.22397	-118.37883	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 1712 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1816	17041-20001-01332	931 N LINDA FLORA DR	90049	5	141B145    99	4368024010	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.0849	-118.46587	Revisions to approved set of plans.  Addition of 45 kVA 240/120V 1ph-3w standby generator, ATS, and backup load subpanel.  (((Plan check new SFD 600 amp.  plan check for power only. Note: Single Family Dwelling permit is under Building application number  15010-20000-02582)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1817	19041-10000-42857	8312 W 3RD ST	90048	5	138B173   896	5511031037	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	11/03/2020 12:00:00 AM	ADDRESS	34.07258	-118.37052	T-24 ENERGY ONLY PLAN CHECK FOR A TI. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. NEW CONNECTED LOAD IS LESS THAN 400A. TOTAL AFFECTED AREA IS 2803 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1818	15041-10000-31804	11845 W OLYMPIC BLVD 1100	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Issued	09/25/2015 12:00:00 AM	PIN	34.03325831	-118.45191172	T-24, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. CONNECTED LOAD <400 AMPS. TOTAL SQ. FT. 10654	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1819	17041-20001-07890	15742 W ARCHWOOD ST	91406	6	180B141   116	2233001026	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.19274	-118.47654	expeditepv1install roof mounted pv system sized 3kw interconnected with msp.This system is an addition to an existing system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1820	12041-10001-18879	400 WORLD WAY Terminal 4-Space 4K	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM			Reviewed by Supervisor	01/30/2013 12:00:00 AM	ADDRESS	33.94221	-118.40701	"DELTA ""B"", ""C"", ""D"" & ""E"" CHANGES TO THE APPROVED PLANS.  (ORIGINALLY CHECKED BY BEHROOZ)ORIGINAL APPLICATION WORK DESCRIPTION: New Tenant.  Full Plan check for Power and Energy for Homeboy Bakery Restaurant (Per applicant).  LAX Terminal 4, Space 4K."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1821	16041-20000-15909	227-229 N LARCHMONT BLVD	90004	4	138B189   553	5515018017	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.07544	-118.32384	NEW 600 AMP SERVICE TO AN EXISTING COMMERCIAL BUILDING.  CORE AND SHELL.  PLAN CHECK FOR POWER ONLY.EACH NEW TENANT SHALL SUBMIT PLANS FOR PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1822	19041-10000-40302	970 W 190TH ST Unit-304	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	06/17/2021 12:00:00 AM	ADDRESS	33.85812	-118.29302	Energy plan check for an office T.I located on the 3rd floor of high rise building. Scope includes new lighting and equipment with a total lighting area of 825-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1823	16041-20000-21871	11121 W PENDLETON ST	91352	6	198B173    45	2538011010	M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.23852	-118.37336	$0 permit fee due to senate bill 1222 from 2012Plan check for PV roof mounted system on industrial facility. System size: 190kW with 5 inverters(36kW) and 728 modules. Net meter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1824	15041-10000-26863	21860 W BURBANK BLVD STE 250	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	34.17198	-118.60379	PC for energy, t24 only. T.I. Existing daily news offices. Total area 1689 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1825	18041-20000-16483	14904 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29414	-118.45511	PV1.  Install 3 kW roof mounted grid tied PV system.  (11) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1826	16041-10000-25219	9269 N DORRINGTON AVE	91331	6	198B153   747	2642006020	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.2381	-118.43949	PV1 SFD TOTAL SYSTEM SIZE 3.6KW AC USING CENTRAL INVERTER SYSTEM WITH 15 MODULES. SYSTEM IS ROOFTOP SOLAR	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1827	13041-20000-28398	9037 N RESEDA BLVD	91324	12	195B125    56	2770004006	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.23471	-118.53634	TI FOR CHANGE OF USE TO HAIR SALON.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1828	14041-20000-23360	7716 N MCNULTY AVE	91306	3	189B109  1032	2108023023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.21055	-118.58201	pv1 sfd. total system size 10kw ac using 2 central transformerless inverters. standard plan. using power optimizers. using total of 44 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1829	10041-10000-14718	3450 S WATT WAY	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.02275	-118.28604	New fire alarm system for office in USC. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1830	17041-20000-25412	1396 W EAGLE VISTA DR	90041	14	162A229    35	5691012036	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	PIN	34.14008288	-118.19424559	PV2. APT. ROOMFOUNTED INSTALLATION . SYSTEM SIZE: 7.4 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1831	17041-10000-17171	727 W CAPITOL DR	90731	15	024B197   405	7445001005	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Closed	09/26/2022 12:00:00 AM	ADDRESS	33.7588	-118.29415	PC for energy only, Outdoor/Indoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 38,075 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1832	13041-20000-26405	800 W WILSHIRE BLVD Suite 600	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.0493	-118.25841	T24 FOR HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON SUITE 600. TOTAL SQRFT 5970	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1833	17041-10000-14073	17200 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.20827	-118.50773	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 228675 SQ. FT. TOTAL OF 78 FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1834	15041-10000-27621	105 S ALAMEDA ST	90012	14	129A215    83	5161018904	[Q]C2-3D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Issued	09/08/2015 12:00:00 AM	ADDRESS	34.04867	-118.23832	new temp power for construction site (2) 600 amp sevices. plan check for power only.  site located in methane zone.  methane report to be submitted at a later time per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1835	18041-20000-12856	6701 S CENTER DR WEST #1200	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	33.97907	-118.39369	Plan check for Title 24 only in existing high-rise building T.I. office space. Total area: 1276 sq ft.  B#18016-1000-06393	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1836	12041-20000-26995	13304 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	PIN	34.31253789	-118.42511113	Enphase system on roof of single family dwelling..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1837	18041-20000-15912	901 N VINE ST	90038	13	144B185  1187	5533018001	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	04/14/2022 12:00:00 AM	ADDRESS	34.0873	-118.3268	New 5-story, 70-unit, mixed-use building over 1 level of subterranean parking garage. Work includes a 3000A 208Y/120V service and a total lighting area of 59,422 sq. ft.Note: Building application has been generated under 17010-30000-02328.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1838	13041-20000-31386	700 N NORTH FARING ROAD	90077	5	144B153   738	4358007025	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.0893	-118.43496	PC FOR POWER AND ENERGY FOR EXISTING SCHOOL. NEW DISTRIBUTION AND NEW LIGHTING. WORK GREATER THATN 400A. ENERGY GREATER THAN 30000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1839	16041-10000-06532	660 S FIGUEROA ST 1 & 6 flr	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	T-24, PC FOR ENERGY ONLY. TI ON THE 1ST FLOOR LOBBY AND 6TH FLOOR SKY LOBBY FOR AN EXISTING COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS 4068 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1840	11041-10000-02353	6333 W 3RD ST # 110	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	New 600 Amp service & panels for a restaurant. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1841	18041-10000-42033	1315 W STORM PKWY	90501	15	045B197    66	7347018034	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.81706	-118.30011	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1842	14041-10000-32449	5249 N LOLETA AVE	90041	14	163-5A227 155	5669011015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Expired	12/15/2016 12:00:00 AM	ADDRESS	34.14273	-118.19827	PV1 Roof mounted  System size: 3.8kW with 16 modules and 1 inverter(3.8kW Solaredge)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1843	10041-20000-18394	1900 S AVENUE OF THE STARS 27th Floor	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	ADDRESS	34.05979	-118.41671	T.I. to existing high rise building.  Install general/emergency lighting in partial of 27th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1844	16041-30000-24360	16047 W LONDELIUS ST	91343	12	195B141   602	2672025018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Refund in Progress	01/05/2017 12:00:00 AM	ADDRESS	34.22948	-118.48209	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (30) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1845	16041-10000-06136	16350 W FILBERT ST	91342	7	225B141   131	2603010906	PF-1VL	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Issued	05/09/2016 12:00:00 AM	ADDRESS	34.3149	-118.48551	IINSTALL NEW FIRE ALARM SYSTEM FOR BARRY J. NORDORF JUVENILE. WITH 25 DIFFERENT BUILDINGS. 25 FA PANELS, 6 COMMUNICATION PANELS, 13 POWER SUPPLY AND 3196 FA DEVICES. (SS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1846	16041-10000-17467	158 N LARCHMONT BLVD	90004	4	138B189   709	5515025008	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.07469	-118.32344	TITLE 24 1904 SQ. FT. TENANT IMPROVEMENT AND CHANGE OF USE FROM RESTAURANT (JAMBA JUICE) TO RETAIL. NEW CONNECTED LOAD LESS THAN 400AMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1847	17041-30000-43140	801 S FIGUEROA ST #1150	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only in existing high-rise building office T.I. Total area: 226 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1848	15041-10000-04322	777 S FIGUEROA ST 47TH Floor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for T-24 interior renovation 14124 sq ft for T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1849	12041-10000-15138	7083 W HOLLYWOOD BLVD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			PC Approved	06/29/2012 12:00:00 AM	ADDRESS	34.10173	-118.34439	T.I. to an existing low-rise office building.  Load is 350A per applicant, previous jobs on other floors may increase load to over 400amps and may require a full plan check subject to field verification.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1850	17041-10001-18964	1830 N CHEROKEE AVE	90028	13	150A185   307	5547004044	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			06/04/2018 12:00:00 AM			PC Approved	06/04/2018 12:00:00 AM	ADDRESS	34.10404	-118.33464	CALCULATIONS TO SHOW AVAILABLE SHORT CIRCUIT CURRENT AT THE FIRE PUMP CONTROLLER((((((((Plan check for power and energy.  Service upgrade and electrical renovation for existing 5 story 64 unit apartment building with 9 hotel units.  New 2,000 amp 208 volt service and 30 HP fire pump.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1851	15041-10001-04351	1111 S FIGUEROA ST	90015	9	127-5A207 149	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.04338	-118.26581	Change to approved set by changing the feeders and breaker size.  All changes are under delta-3 only((((Plan check for fuel cell. Installation of Natureal gas powered Full Cell.Note: Address to be determined prior pulling permit)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1852	10041-10000-20454	6524 N PLATT AVE	91307	3	180B093   512	2036024053	(Q)C1-1VL, (Q)C4-1VL, C1-1VL, C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	12/15/2010 12:00:00 AM	ADDRESS	34.18859	-118.64245	CHANGE OF USE FROM RETAIL TO BAKERY  ( TAKE OUT )PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1853	17041-20000-10306	12105 W WATERFRONT DR UNIT 2C	90094	11	105B161  1199	4211010048	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	33.98095	-118.40764	Change of use and first time tenant - from (E) core and shell retail space to coffee shop.  Plan check for power and energy.Building permit filed under 17016-10000-01184	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1854	19041-10001-02400	9211 N BALCOM AVE	91325	12	198B129   332	2766004011	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.23791	-118.5217	NEW ROOF MOUNTED 11.52 KW PV SYSTEM ON A SINGLE FAMILY HOUSE WITH 32 PV PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1855	16041-10002-25130	15579 W MEADOWGATE ROAD	91436	5	165B141   244	2285003046	R1-1	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	34.14953	-118.47409	12/29/16Changes to an approved set of plans. All changes are clouded under delta 3. Changes include upgradig main service panel. PC for point of interconnection to service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1856	17041-10000-00654	518 N GRAMERCY PL	90004	4	141B193  1072	5522013015	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			01/13/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.08086	-118.3124	FULL PC FOR POWER AND ENERGY FOR A NEW 4 STORY 51 UNIT APARTMENT BUILDING. OVER ONE STORY PARKING GARAGE. SCOPE INCLUDES A NEW 2000A 120/240 3 PHASE 3 WIRE SERVICE, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS(3 DIFFERENT TYPES OF PANELS FOR ALL UNIT TYPES). TOTAL AFFECTED AREA IS 28220 SQ. FT. B#16010-10000-03398	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1857	15041-20000-15460	9650 N VANALDEN AVE	91324	12	201B121   492	2762033003	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.24609	-118.54905	Plan check for a PV1 roof-mounted PV system. System size is 7.5 kWac and consists of (1) inverter, and (30) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1858	16041-20000-04994	4410 S BUDLONG AVE	90037	9	111B197   141	5017017026	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.00325	-118.29574	PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE FROM CHURCH/SCHOOL BLDG. TO ELEMENTARY SCHOOL. FIRE ALARM VARIANCE HAS BEEN SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1859	13041-10000-07975	102-116 W 5TH ST	90013	14	129A211   155	5149037010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			03/28/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Issued	08/21/2013 12:00:00 AM	ADDRESS	34.04673	-118.2488	"Mixed-use apartment/commercial 13-story with basement building.  Historic hotel building with retail spaces on street level and apartment units above.  New services 800A and 1000A.  New main switchboards, panels, transformers, and branch circuits for the kitchennet equipment installation.  Plan check for power and energy.""COMPLY WITH DEPARTMENT ORDER effective date07/11/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1860	19041-20000-32382	6400 N LAUREL CANYON BLVD SUITE 400	91606	5	180B165   677	2322007057	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.18693	-118.3963	T24 PLAN CHECK  LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 13420 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1861	10041-10000-16573	1216 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.05004	-118.22651	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1862	17041-10001-41776	4008 N GRIFFIN AVE	90031	1	144A225   154	5207017004	[Q]RD3-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.0897	-118.20558	Changes to an approved set of plans. Changes include relocating modules on the roof, revising roof-layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1863	15041-10000-37338	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	TEMPORARY POWER FOR CONSTRUCTION SITE.  PLAN CHECK FOR POWER ONLY PHASE1,2,3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1864	16041-30000-38613	1201 E 7TH ST	90021	14	126A213   652	5147034016	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.03762	-118.24209	Plan check for New Fire alarm system for 3 story appt Hotel 48 units. Total fire alarm devices: 184 and 1 fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1865	18041-10001-14441	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Closed	02/12/2020 12:00:00 AM	ADDRESS	34.23911	-118.3725	Change to approved set by modifying the power plan, all changes under delta-3 only.(((PC FOR POWE AND ENERGY FOR EXISTING CORE/SHELL WAREHOUSE AND OFFICE SPACE. SCOPE INCLUDES NEW PANELS, NEW GENERATOR 25KW,CIRCUITS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 32356SQ.FT. B# = 18016-10000-12129)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1866	18041-20000-14673	4864 W MELROSE AVE	90029	13	141B193   595	5521004030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			04/20/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	06/24/2021 12:00:00 AM	ADDRESS	34.08332	-118.30647	Plan check for power and energy. Project site is a 6-story, 51-unit mixed use apartment building over 1 level of basement parking garage. Work includes a 2,000-amp service and a total lighting area of 39,891 sq. ft.Note: Building application has been generated under 16010-10000-05517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1867	14041-20000-22247	18901 W BAHAMA ST	91324	12	195B121   119	2784023019	RS-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.23337	-118.54514	pv1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(22) TRINA SOLAR TSM 255 PV MODULES(22) SOLAR EDGE P300 OPTIMIZERS(1) SOLAREDGE SE5000A-US-ZB-U TRANSFORMERLESS INVERTERRedesign of system from permit #14041-20001-16216	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1868	12041-10000-09885	12975 N BRADLEY AVE	91342	7	222B145   166	2506003021	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.30539	-118.46035	New fire alarm to replace an existing one in an existing single-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1869	10041-20000-20577	5000 N VAN NUYS BLVD 4th Floor	91403	4	171A151   223	2248008087	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM			PC Approved	10/15/2010 12:00:00 AM	ADDRESS	34.16138	-118.44849	Plan check only for T24 Energy (general/emergency) lighting on the 4th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1870	14041-20001-00053	17550 W LANARK ST	91325	12	189B129   142	2201005008	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.21786	-118.516	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTERS USING POWER OPTIMIERS. NONSTANDARD PLAN.(((EXPEDITE)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1871	18041-20000-31984	959 E STADIUM WAY	90012	1	136-5A213 144	5406023004	R4-1-O	Central	Central City North	Los Angeles Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			08/27/2018 12:00:00 AM			Reviewed by Supervisor	10/24/2018 12:00:00 AM	ADDRESS	34.06713	-118.24129	Plan check for power and energy. Project site is an 8-story, 151-unit apartment building with parking garage. Work includes a 4,000-amp service and a total lighting area of 153,272 sq. ft. Project is located in a methane zone.Note: Building application has been generated under 16010-20000-03970	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1872	19041-10000-53301	12224 W DARLINGTON AVE	90049	11	129B145   975	4264023022	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.04645	-118.47154	(E-PLAN)CHANGES TO AN APPROVED SET. SCOPE OF WORK INCLUDES RELOCATION ELECTRICAL EQUIPMENT. $0 PERMIT FEES DUE TO SENATE BILL 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1873	17041-10000-06129	2535 S BARRINGTON AVE	90064	11	120B153   217	4257013042	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.02775	-118.44299	T-24, PC FOR ENERGY ONLY. CHANGE OF USE OF ONE OF THE RETAIL STORE TO RESTAURANT.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1364 SQ. FT. B#16016-20000-26615	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1874	18041-30001-18099	2205 S STONER AVE	90064	11	123B149   476	4260011002	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	34.03331	-118.44863	12/27/2018 Changes to an approved set of plans. Revisions have been made to have installation reflect field conditions. Exit sign locations and path of egress have been indicated on floor plans.Note: Electrical permit fees have been paid for under 18041-30000-19615****Original Scope of Work*****TI IN AN EXISTING 2 STORY OFFICE BUILDING.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1875	17041-10000-40306	777 S FIGUEROA ST 42 ND FL	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	ALTERATIONS IN THE CORRIDOR/RESTROOMS/ELEVATOR LOBBYPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1876	13041-10000-12062	380 WORLD WAY #T53-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check power and energy. First-time tenant in retail space at Tom Bradley Int'l Terminal at LAX (Coach). Space #T53-R	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1877	16041-10000-29892	1611 W 6TH ST	90017	1	132A205    57	5153005003	C2-4	Central	Westlake	Westlake North		2091.02	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.0572	-118.26917	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 2020 SQ FT. (outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1878	16041-10000-17608	6336 S BRYNHURST AVE	90043	8	105B185  1029	4006008019	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			05/19/2016 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	33.98181	-118.33365	New 12 unit 3 story Apartment building with attched garage on first story level, (4) typical units. 600 A service. Total area 11,360 sq.ft (indoor+outdoor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1879	14041-20000-07517	5501 W 102ND ST	90045	11	090B173   177	4129029011	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	33.94376	-118.37663	PC FOR REFUELING DISPENSERS AT A CAR RENTAL LOT. 3 NEW DISPENSERS AND A STORAGE TANK. PC FOR HAZARDOUS LOCATION IN ACCORDANCE TO ARTICLE 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1880	14041-20000-22615	8442 N AQUEDUCT AVE	91343	12	192B141   278	2673013028	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/26/2016 12:00:00 AM	ADDRESS	34.22409	-118.4741	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(28) TRINA SOLAR TSM-255 MODULES(1) POWER ONE PVI-6.0 TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1881	16041-10000-44984	10250 W SANTA MONICA BLVD STE. 2990	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Tender Green"" Ste. 2990.  Install new electrical equipments,,  total affected area: 2,630 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1882	15041-10002-33858	20350 W VENTURA BLVD	91364	3	171B113    28	2166035030	(Q)CR-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.16881	-118.57601	04/13/16Changes to an approved set of plans. All changes are made under delta 2. Changes to reflect what is on field.  NOTE: PERMIT PULLED UNDER PCIS#15041-10000-33858(((((((PERMIT FEES $0.00 BY STATE SENATE BILL NO. 1222PV2, ROOF MOUNTED SOLAR SYSTEM TO AN (E) OFFICE BUILDING. (160) MODULES AND (6) INVERTERS. (160) CANADIAN SOLAR CS6X-315P(3) SMA SUNNY BOY SB900TL-US(3) SMA SUNNY BOY SB7000TL-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1883	14041-10001-34533	12516 N MCLENNAN AVE	91344	12	219B133   379	2609025058	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	34.29723	-118.50138	Expedited plan check per applicant request.  PV1.  Install 8.83 kW roof-mounted, utility-interactive PV system.  (27) modules with (2) transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1884	10041-20000-02486	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	03/30/2010 12:00:00 AM	ADDRESS	34.07157	-118.36014	BARBER SHOP CLUB ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1885	11041-10000-04976	1241 S SOTO ST	90023	14	121-5A221 147	5170017030	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Public Safety Only			03/14/2011 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.02743	-118.21975	REPLACING FIRE ALARM PANEL ONE FOR ONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1886	15041-10000-11566	850 E 111TH PL	90059	8	088-5A209 241	6071022006	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM			Reviewed by Supervisor	05/19/2015 12:00:00 AM	ADDRESS	33.93557	-118.25914	PC FOR POWER. INSTALLING A NEW COMPERESSED NATURAL GAS(CNG) VEHICLE FUELING SYSTEM. INCLUDES 2 COPOMPRESSORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1887	19041-10000-07269	8129 W 3RD ST	90048	5	138B173   885	5511021031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.07239	-118.36672	T-24 PC FOR A TI OF A RETAIL STORE ( JAND INC EYE WEAR). (NO CHANGE OF USE). SCOPE INCLUDE NEW 200A SERVICE, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1088.9 SQ.FT B#: 19016-10000-03350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1888	17041-30000-38677	19191 S VERMONT AVE Suite 900	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	33.85656	-118.29099	Plan check for Title 24 only. Project site is an existing commercial tenant space on the 9th floor of high-rise building. Project scope is a tenant improvement. Total lighting area = 10,020 sq. ft. B#17016-10000-31730NOTE: Permit paid under PCIS#17041-40000-43207.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1889	11041-20001-27234	8496 S OSAGE AVE	90045	11	096B173    80	4127024018	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM			PC Approved	05/16/2012 12:00:00 AM	ADDRESS	33.96159	-118.37861		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1890	13041-10000-05060	325 W ADAMS BLVD	90007	9	123A205   197	5126018035	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM			PC Approved	03/07/2013 12:00:00 AM	ADDRESS	34.02712	-118.27319	(((((((CHANGES MADE TO TITLE 24. DECREASED LIGHTING THEATER AREA. ADDING ISLE LIGHTING AND CHANGED GENERAL LIGHTING FIXTURES. 1740 SQRFEET. ORIGINAL PLAN CHECK APPLICATION#: 10041-10000-25737)))))))))NEW 6 LEVEL MIXED USE RESIDENTIAL (915 UNITS, 5 LEVELS) & RETAIL (1 LEVEL).  WITH A 4160 V, 1000 AMP SERVICE.  PLAN CHECK IS FOR POWER & ENERGY.   (3 LEVELS OF PARKING STRUCTURE BELOW SUBMITTED UNDER EPC #10041-10000-25736 & Bldg PC# 10010-10000-01204).  VARIANCE FOR WILL BE REQUIRED TO SEPERATE THE FIRE LIFE SAFETY SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1891	11041-20000-10755	8141 S GULANA AVE	90293	11	096B153     1	4115021800	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM			Corrections Issued	05/28/2011 12:00:00 AM	ADDRESS	33.96169	-118.43753	PLAN CHECK FOR GAS DETECTION SYSTEM AT PLAYA DEL REY COMPRESSOR STATION (SO CAL GAS CO.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1892	15041-20001-09463	911 N AVENUE 64	90042	14	156A233   177	5486028013	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.12238	-118.17719	07/14/2015 Changes to an approved set of plans. Changes include the removal of (5) PV modules and rearrangement of PV strings.*****Previous Work Description*****Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system with three branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1893	17041-20000-12638	4690 W COLORADO BLVD	90039	13	162B201    75	5593018013	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.14012	-118.27542	"4/18/2017Changes to an approved set of plans.  changes noted delta 3. changes reflect (4) new motor loads connected to MCC ""CHILLER"".  Plan check for power only.(((Changes to approved set.  Addition of new 7.5 kVA power center.  Updated single line diagram and floor plan.REF HVAC APP 16044-20000-11351)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1894	18041-10000-22128	1828 E CESAR E CHAVEZ AVE #4500	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.05014	-118.21571	PLAN CHECK FOR TITLE 24 ONLY FOR NON HIGHRISE BUILDING- NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT FOR (E) MEDICAL OFFICE FOR SUITE #4500 - TOTAL AFFECTED AREA = 1592 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1895	12041-10001-29288	700 W WORLD WAY Terminal 7-Space 7C	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	PIN	33.94153561	-118.3984113	(((4/10/2014- CHANGES MADE TO APPROVED SET. REMOVED CURRENT LIMITERS FROM TRACK LIGHTS AND PROVIDED NEW CURRENT LIMITING PANEL.)))Plan check for power and energy. Terminal 7, Space 7C. 5936 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1896	14041-10000-27149	5620 S MESMER AVE	90230	11	105B165   299	4220015031	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	33.98511	-118.39992	Power plan check for a temporary power installation for an existing health care facility remodel.  Medical equipment (CT scan) will be powered by this system.  1 new 3 phase 210 KVA step-up transformer (208 V to 480 V) will be installed which connects to a single recepticle.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1897	18041-10000-49153	3664 S BOISE AVE	90066	11	114B153  1162	4246012015	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	02/23/2019 12:00:00 AM	ADDRESS	34.00561	-118.43863	INSTALLING (2) TESLA WALL MOUNTED ENERGY STORAGE SYSTEM ON EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1898	14041-20000-24691	5900 W WILSHIRE BLVD 1700	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for energy only. TI to 17th floor of existing high rise office building. New lighting incld. emergency, new receptacles. 11,536sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1899	11041-10000-23947	445 N MANSFIELD AVE	90036	5	141B181  1289	5524029022	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	03/21/2012 12:00:00 AM	ADDRESS	34.07961	-118.34091	New 12.42KW,Rooftop, Photovoltaic System for a single family residence.   54 pv panels and one inverter with 6 strings of 9 pv panels going to the inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1900	17041-10000-25122	5306 S COMPTON AVE	90011	9	108B213   152	5105003905	OS-1XL	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	33.99463	-118.2476	PC FOR LIGHTING UPGRADES TO MORE ENERGY EFFICIENT TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1901	10041-20000-16193	9414 W VENICE BLVD	90232	10	120B165   817	4206028019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.02508	-118.39513	PLAN CHECK T-24 ENERGY FOR T.I.  FOR SUBWAY TAKE OUT RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1902	12041-10000-04710	1301 S BROCKTON AVE 1-49	90025	11	126B145   184	4263023092	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			03/01/2012 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.04404	-118.46381	This is a four story apartment bldg, 49 units, subterenian parking, variance needed to separate fire alarm. 34000  sqft of title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1903	10041-20000-03397	1743 N CAHUENGA BLVD	90028	13	148-5A187  48	5546006007	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	02/25/2010 12:00:00 AM		Permit Finaled	05/13/2010 12:00:00 AM	ADDRESS	34.1029	-118.32971	night club /restaurant energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1904	19041-20000-25852	6056 W JEFFERSON BLVD	90016	10	117B169     7	4204008011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		7025.02	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Issued	08/12/2019 12:00:00 AM	ADDRESS	34.02058	-118.3807	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1905	18041-20000-31514	1812 1/2 N MELHILL WAY	90049	11	135B133   261	4432011050	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.06801	-118.50009	Installation of a 5.0 kW/13.5 kWh energy storage system and associated distribution (critical load back up panel).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1906	19041-10000-48850	2200 S 6TH AVE	90018	10	123B189    96	5060024028	RD2-1-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Issued	11/26/2019 12:00:00 AM	ADDRESS	34.03681	-118.32349	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1907	18041-10000-30240	17601 W LASSEN ST	91325	12	201B129     4	2734009012	RA-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.25055	-118.51801	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1908	17041-20000-02316	8508 N LURLINE AVE	91306	3	192B109   181	2780018021	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.22486	-118.58401	pv1install roof mounted pv system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1909	17041-10000-23336	11401 N PORTER RANCH DR BLDG 5	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	05/18/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 41 unit apartment with 1600 amp 208 volt service.       Building 5 of 10.  Type IV.       Building permit #17010-10000-02382	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1910	18041-20001-04598	3673 N BERRY DR	91604	2	162B173   923	2378025030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	PIN	34.13738075	-118.37867973	Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (33) modules, (33) micro-inveters, (3) load centers, and (2) Tesla PowerWalls. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1911	12041-10000-15576	1524 S ABBOT KINNEY BLVD	90291	11	108B145  1555	4238005027	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			PC Approved	07/18/2012 12:00:00 AM	ADDRESS	33.98992	-118.46401	Plan check for T24 Energy (indoor and outdoor) for retail space in existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1912	14041-20001-21023	1117 N VISTAGRANDE DR	90272	11	132B121   247	4420026019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM			PC Approved	08/13/2014 12:00:00 AM	ADDRESS	34.05799	-118.55052	Fee for expedite only.*****New roof mounted PV system with total system size 9KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1913	10041-10000-24441	423 S MOLINO ST	90013	14	127-5A215 348	5163021021	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.04227	-118.23415	INSTALL A 11KW PV SYSTEM ON THE ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1914	13041-10000-31025	8500 W BEVERLY BLVD SPACE #691	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	"TITLE 24 PART 6 ENERGY; TENANT IMPROVEMENT FOR ""S.Y.L.K"" IN BEVERLY CENTER. UNIT EQUIPMENTS PERMITTED IN TENANT SPACES PER SUPERVISOR REVIEW. ELECTRICAL PLAN CHECK PULLED UNDER SUPPLEMENTAL APPLICATION 10001 SERIES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1915	17041-10000-10729	3432 E 14TH ST	90023	14	118-5A225 402	5190032007	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.01715	-118.20561	PC FOR POWER UPGRADE TO 800A SERVICE. REFEED EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1916	18041-20000-02615	700 S FLOWER ST #850	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Tenant improvement of (E) commercial office space on 8th floor of highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1917	15041-20001-33093	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	11/03/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1918	18041-20000-14664	1827 S MIDVALE AVE	90025	5	129B153   690	4323006027	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			04/20/2018 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	02/10/2021 12:00:00 AM	ADDRESS	34.04855	-118.43747	Plan check for power and energy. Project site is a 5-story, 17-unit apartment building over 1-level of basement parking garage. Work includes an 800-amp service and a total lighting of 19,441 sq. ft.Note: Building application has been generated under 17010-20000-04861	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1919	12041-10000-19383	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check power and energy for Fox Building 100 2nd floor office TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1920	16041-20000-05620	18649 W CALAHAN ST	91324	12	198B121   702	2763012020	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.23653	-118.53989	Plan check for PV roof mounted system. System size: 12.0kW with 38 modules and 2 inverters(5.0kW and 7.0kW) connected to 100A sub-panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1921	10041-30000-07889	6310 W SAN VICENTE BLVD 1ST FLOOR	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM			PC Approved	04/29/2010 12:00:00 AM	ADDRESS	34.06084	-118.36757	LIGHTING IN A RESTAURANT. THIS PLAN CHECK IS TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1922	19041-10000-27422	8534 N HATILLO AVE	91306	3	192B113   122	2782018006	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.22551	-118.56499	NEW ROOF MOUNTED 12.24KW PV SYSTEM WITH 36 PANELS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1923	14041-10000-00075	4214 N FULTON AVE 1-11	91604	2	165B157  1198	2375017180	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Apartment			01/02/2014 12:00:00 AM	05/06/2015 12:00:00 AM		Issued	05/06/2015 12:00:00 AM	ADDRESS	34.14708	-118.42231	PLAN CHECK FOR POWER AND ENERGY FOR 11  APARTMENTS UNTS.  800 AMP SERVICE PLUS 400 AMP SERVICE. 11 NEW PANELS. THE APPLICANT HAS TO PROVIDE  T24 SHEETS.TOTAL AREA  IS AROUND 50000 SQ FT.(MEHDI)*** THE PLAN HAS TO BE CHECKED UNDER CEC 2010.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1924	16041-20001-12063	11427 N PORTER RANCH DR	91326	12	213B113   325	2701072004	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.27867	-118.57253	[[[1/11/18  CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING TO LOAD SIDE CONNECTION AND DERATING MAIN]]]Plan check for a PV2 carport PV system. System size is 111.6 kWdc and consists of (6) inverters, (372) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1925	18041-20000-36801	12007 N MIRABEL WAY	91326	12	216B109   171	2701081020	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.29079	-118.58238	Plan check for PV roof mounted system, system size: 5.03kW with 15 AC Modules. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1926	15041-10000-36990	639 N ADELAIDE DR	90402	11	123A133    16	4410001050	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.03296	-118.50911	PV1, 7.6KW roof -mounted system with (32) TSM -240 modules, and (2) PVI 3.8-I-OUTD inverters interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1927	13041-10001-21088	255 S GRAND AVE	90012	14	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.05332	-118.25122	Change to approved set by removing overide swtiches at the public corridor area. all changes are under delta-2 only.(((TITLE 24 PART 6 ENERGY EXPRESS PERMIT FOR  516 units to be installed on existing branch circuits (for inspection fees). Removal and replacement of wall mounted light fixtures (fluorescent to LED) of common area corridors of highrise building (3rd floor to 27th floor - no 13th floor).  Combined corridor area revised to ~34,000 sq ft. All exit signs are existing to remain. Title 24 plan check only.Generator load calculations: LED ~20W Fixtures in corridor are lower wattage than lights being replaced. no added load.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1928	15041-20000-11893	12446 W OSPREY LANE Unit 1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.97949	-118.41001	Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (8) modules, and (1) inverter. This is Unit 1 of 3.Note: PV solar clearance shall apply to the three units under this PCAM number.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1929	17041-20001-38969	509 S BENTLEY AVE	90049	5	135B145   478	4366033026	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	ADDRESS	34.06639	-118.4593	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1930	11041-10003-01082	533 S WESTERN AVE C	90020	4	135B193   779	5503018003	C2-1	Central	Wilshire			2117.04	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM			PC Approved	11/28/2011 12:00:00 AM	ADDRESS	34.06437	-118.30928	T24Energy/Emergency revision to approved plans. Revision clouded to reflect as build condition.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1931	19041-20000-19952	7665 N SALE AVE	91304	12	189B097  1169	2013018006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.21021	-118.61883	PV1.  Install 13.86 kW / 11.78 kW AC roof mounted grid tied PV system.  (42) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1932	12041-10000-21563	10364 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.25874	-118.57962	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO EXISTING RESTAURANT. PERMIT FOR NEW LIGHT FIXTURES AND UNIT EQUIPMENT ON EXISTING BRANCH CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1933	11041-20000-03624	444 S FLOWER ST 7th Floor	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	T.I. to a high rise building.  Install generarl/emergency lighting in restrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1934	08041-10001-12135	621 S WESTERN AVE 3RD & 4TH-FLOORS	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM			PC Approved	02/02/2010 12:00:00 AM	ADDRESS	34.0628	-118.30928	DELTA 7 &  8 REVISIONS TO  THE CONCESSION COUNTER/AREA ON THE THIRD  AND FOURTH FLOORS- EXTENSION OF THE CONCESSIONS AREAS AND NEW LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1935	13041-20000-35580	12708 W CASWELL AVE 1-5	90066	11	111B153  1021	4236019003	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			12/20/2013 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	33.99851	-118.43634	CONSTRUCTION OF NEW 5 UNIT APARTMENT BUILDING. 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1936	18041-10000-13522	1962 N ECHO PARK AVE	90026	13	144A211   346	5420033009	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.08735	-118.2502	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1937	14041-20000-02664	925 W WEST 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.0239	-118.28647	T24 FOR CONTROLS ONLY FOR PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1938	17041-20000-10254	865 S FIGUEROA ST #3300	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLANCHECK FOR T24 ENERGY. TI ON 33RD FLOOR (APPROX 5168SF) OF EXISTING HIGH-RISE OFFICE BUILDING. SUITE 3300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1939	18041-10000-45264	660 S FIGUEROA ST # 1050	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Corrections Issued	11/28/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	Energy plan check for an office T.I located on the 10th floor of a high rise building. Scope includes new lighting and equipment with a total area 3020-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1940	13041-10000-19993	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Info Complete	09/04/2013 12:00:00 AM	ADDRESS	34.05979	-118.41671	New boilers and pumps in industrial plant - installation of 3 new panels to supply power.  Permit obtained by applicant under online permit 13041-90000-26673.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1941	16041-20002-20407	13930 S FIGUEROA ST	90061	15	075B201    24	6132044028	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM			PC Approved	10/28/2016 12:00:00 AM	ADDRESS	33.90432	-118.28254	RE-PLANCHECK ONLY DUE TO LOST PLANS. Plan check for PV roof mounted system. System size: 40kW with 160 modules and 2 inverters(20.0kW) on commercial building .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1942	14041-10000-07798	9413 S SPRING ST	90003	8	093A203    60	6053006922	RD1.5-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Apartment			03/24/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	33.95054	-118.2769	New fire alarm system for 49 unit apartment building.  New FACP and 181 devices total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1943	19041-20000-10850	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Issued	03/26/2019 12:00:00 AM	ADDRESS	34.26153	-118.50259	Exterior lighting for new solar canopy structure.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1944	14041-20000-23164	1000 W WILSHIRE BLVD STE 230	90017	14	130-5A207 262	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.05085	-118.26078	TENANT IMPROVEMENT TO DIVIDE ONE SUITE INTO TWO. PLAN CHECK FOR T24 ENERGY ONLY. EXISTING LIGHTING TO REMAIN. NEW CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1945	11041-10000-26272	6222 W SANTA MONICA BLVD	90038	13	144B189   698	5534022033	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.09053	-118.32534	TI IN A 2 STORY OFFICE BUILDING. PLAN CHECK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1946	16041-10001-42807	500 WORLD WAY T5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			PC Info Complete	07/10/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	supplementary pc for new lights to an approved set. PC for new general and emergency lights. NOTE: This approval is for T24 supplemental only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1947	15041-20000-00679	9403 N SYLMAR AVE	91402	6	198B149   166	2644029***	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM			Corrections Issued	01/09/2015 12:00:00 AM	ADDRESS	34.24106	-118.4477	PV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC USING 17 MODULES AND SINGLE TRANSFORMERLESS INVERTER. THIS IS A SIGNLE FAMILY DWELLING CONNECTED TO UTILITY SERVICE AS A MULTI-FAMILY. THESE ARE CONDOS. SHARING SINGLE SERVICE POINT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1948	10041-20000-01800	21201 W KITTRIDGE ST 1-438	91303	3	180B105    38	2148030031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Apartment			02/04/2010 12:00:00 AM	03/25/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.19131	-118.59428	FIRE ALARM SYSTEM FOR NEW TYPE V-A, 4-STORY 438 UNIT APTARTMENT BUILDING- GREEN PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1949	18041-20001-08083	19970 W FRIAR ST	91367	3	180B113   795	2134036007	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Issued	03/30/2018 12:00:00 AM	ADDRESS	34.18673	-118.56852	3/30/2018supplemental permit to correct system size to 10.4kw AC.permit fee $0.00 department error.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1950	17041-10000-24141	10250 W SANTA MONICA BLVD # 1340	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	first tenant-Tesla-IN NEW COMMERCIAL SPACEFULL PLAN CHK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1951	12041-10000-22802	2852 W SUNSET BLVD	90026	13	141A205    29	5426020009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.01	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	09/25/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.08259	-118.27323	CHANGE OF USE OF COMMERCIAL TENANT SPACE FROM RETAIL TO RESTAURANT ( BLACK HOGG)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1952	16041-10000-08109	1740 S WESTMORELAND BLVD	90006	10	126B193   606	5074019004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM			Reviewed by Supervisor	03/21/2016 12:00:00 AM	ADDRESS	34.04162	-118.30641	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDNENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.75KWdc / 5.375KWac. (25)MODULES-SILFAB SOLAR SLA-M270(25)MICROINVERTERS-ENPHASE M215-60-2LL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1953	12041-20000-23471	8557 N ROBERT AVE	91352	6	192B173   191	2408018012	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.22501	-118.37054	Enphase PV system on roof of single family dwelling with service upgrade and PV subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1954	19041-10000-08022	12154 W MONTAGUE ST	91331	7	204B165    89	2537018027	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	12/21/2020 12:00:00 AM	ADDRESS	34.25712	-118.39806	PC for Power only. Scope includes a new installation for a new 1000A 480/277V 3 Phase, 4 Wire Service/Distribution board. Service will be used for a future PV solar installation. Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application #19041-10000-08025	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1955	16041-10000-45490	5921 N OWENSMOUTH AVE	91367	3	177B105    98	2146006048	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.17781	-118.60176	PC  T.I CHANGE OF USE FROM RESTURANT TO OFFICE FOR TITLE 24 ENERGY ONLY.SCOPE INLCLUDES NEW LIGHTS AND RECEPTACLES.    TOTAL AFFECTED AREA 9721 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1956	14041-20000-18291	459 N SURFVIEW DR	90272	11	129B113    12	4443020002	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM			Corrections Issued	07/12/2014 12:00:00 AM	ADDRESS	34.04917	-118.56729	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 10.5 KW AC / 12KW DC. USING 44 MODULES. USING MICROINVERTER SYSTEM. NONSTANDARD PLAN. ENPHASE M250.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1957	17041-10000-18688	10731 N WOODLEY AVE	91344	12	207B141   275	2680007006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.26574	-118.48499	Pv1 roof mounted system with 3.8KW and (12) modules and power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1958	18041-20001-03145	19118 W MARILLA ST	91324	12	201B121   408	2762006012	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Issued	05/10/2018 12:00:00 AM	ADDRESS	34.24716	-118.55032	05/10/2018 Plan check for the addition of (2) Tesla PowerWalls onto an existing PV system. There are now a total of (3) PowerWalls.*****Previous Work Description*****Plan check of the addition of (1) Tesla PowerWall to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1959	14041-20000-06889	11601 W WILSHIRE BLVD 12TH FLR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	PC FOR T24 ENERGY ONLY. TOTAL AREA 17677 SQ FT. WORK DONE ON 12TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1960	16041-10000-20552	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Closed	06/29/2021 12:00:00 AM	ADDRESS	34.05715	-118.41482	PC FOR METHAN MITIGATION SYSTEM. TOTAL OF 107 DEVICES AND  CONTROL PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1961	17041-10000-42919	17660 W VENTURA BLVD	91316	5	171B129   388	2290010002	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.16214	-118.51822	FULL PC FOR POWER AND ENERGY FOR A NEW RESTAURANT. SCOPE INCLUDES A NEW1200A 120/208V 3 PHASE 4 WIRE SERVICE/DISRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 17550 SQ. FT.  B#17010-10000-04695	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1962	14041-10000-31667	20324 W STRATHERN ST	91306	3	189B113   509	2107025041	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Expired	12/09/2016 12:00:00 AM	ADDRESS	34.21547	-118.57621	PV1.  Installation of 3.924 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1963	15041-20000-26871	22950 W VANOWEN ST	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.19343	-118.62746	Existing commercial building. Replacing existing 2 services with new single 1200A service. Adding exterior lighting. Total sqft. 10,431.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1964	17041-10000-01234	2138 N HILLHURST AVE	90027	4	150B201    98	5590001024	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.11116	-118.28727	Full Plan check for power and energy. First time tenant, TI to Starbucks coffee shop. Existing Service rated at 1200A. Scope includes new panels, new circuits, and new lights.  Total area: 3,287. Core and shell Permit under  App. No. 16041-10000-33191	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1965	19041-20000-31264	334 S RIMPAU BLVD	90020	4	135B185   170	5505009004	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	10/12/2019 12:00:00 AM	ADDRESS	34.06775	-118.33018	PV1. INSTALL 7.26 KW DC SYSTEM SIZE (22) SOLAR PV MODULES WITH OPTIMIZERS (P400) ON 400 AMP EXISTING SERVICE. SCOPE OF WORK INCLUDES (3) TESLA POWERWALL STORAGE BATTERIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1966	18041-10000-43442	13900 N PICKADILLY PL	91342	7	228B165     7	2582038032	RE11-1-H	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.32549	-118.40593	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 34 MODULES (PANASONIC N330) , 34 OPTIMIZER (SE P400) AND A CENTRAL INVERTER (SE11400H-US).  SYSTEM SIZE IS 11.22KWdc and 11.4KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
1967	16041-10000-20246	11925 W WILSHIRE BLVD Suite 300	90025	11	129B145   934	4265014095	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.04655	-118.46473	Title 24 plan check only.  Total area = 3,856 sq. ft.     T.I. to top floor of existing three story office building.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1968	18041-10000-30237	12848 W PIERCE ST	91331	7	207B161    22	2536016009	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.26693	-118.41349	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
1969	14041-20001-03419	11214 W MORRISON ST	91601	2	168B173    16	2353016003	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			12/31/2014 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	34.16065	-118.37499	[12/31/2014] CHANGES TO AN APPROVED SET OF PLANS.  DOWNSIZING SEVEN UNIT APARTMENT TO SIX UNIT APARTMENTT.  CHANGES NOT CLOUDED ON PLANS .  PLAN CHECKER TO VERIFY CHANGES.  FEE TIME ESTIMATED PLAN CHECKER TO VERIFY.  PERMIT TO BE ISSUED UNDER THE MASTER PERMIT  14041 20000 03419((NEW 6 UNIT APT. SERVICE SIZE 600A DELTA. FIRE ALARM VARIANCE HAS BEEN FILED))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1970	19041-20000-06117	959 N SEWARD ST Ste 303	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	TI to (E) spec suite.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1971	15041-20000-06836	3543 W CARNATION AVE	90026	13	145-5A205  97	5429030001	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.09398	-118.27341	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel. (16) Solar World 280W modules(16) Solar Edge P300 Power optimizers(1) Solar Edge SE5000A Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1972	12041-20000-30169	13309 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	PIN	34.31253789	-118.42511113	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1973	19041-20000-52993	2121 E 25TH ST	90058	14	117A217    13	5167007020	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	10/26/2020 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.0149	-118.23295	"SERVICE UPGRADE TO 1,200 AMPS,  NEW PANELS AND EQUIPMENTS. ENERGIZING AN EXISTING ""ROCK CRUSHER"" RATED  @ 1200AMPS AND SHERT CIRCUIT RATING OF 42KAIC, WICH MUST BE RE-CERITIFIED BY (UL) AT THIS NEW LOCATION."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1974	15041-10000-27886	3417 S ARLINGTON AVE	90018	8	096A205   325	6041005031	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.02495	-118.31777	PV1INSTALL ROOF MOUNTED PV SYSTEM STANDARD PLAN SIZED 5.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1975	14041-20000-21341	11852 N FELLOWS AVE	91340	7	216B157    75	2524004012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.285	-118.42058	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(22) REC SOLAR REC260PE MODULES(22) SOLAR EDGE OPTIMIZERS P300(1) SOLAR EDGE SE5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1976	19041-20000-17777	9120 W ORIOLE WAY	90069	4	147B169   820	5560006014	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM			Reviewed by Supervisor	05/24/2019 12:00:00 AM	ADDRESS	34.09669	-118.38872	Plan check for power only. New 3-story single family dwelling with basement and attached garage. 800A service 120/240 3phase 4-wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1977	16041-10000-02471	18455 S FIGUEROA ST	90248	15	060B201    20	7339008034	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Issued	05/19/2016 12:00:00 AM	ADDRESS	33.86353	-118.28198	PC FOR POWER ONLY. SCOPE INCLUDES UPGRADING THE SERVICE OF AN EXISTING COMMERCIAL BUILDING 'D' FROM A 2500A SERVICE TO A 5000A SERVICE. ALSO, ADDING TWO NEW 5000A SWITCHBOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1978	19041-20000-50319	515 S FLOWER ST 8TH FLR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 energy only for new lighting. Total area: 2261 sq ft. B#19016-10000-15810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1979	13041-10001-34389	7515 N ZOMBAR AVE	91406	6	186B145   300	2222014031	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.20706	-118.46741	Expedited RSES plan check per applicant request.{{PV1, install 6 kw DC roof-mounted solar array for a 2-story house with power optimizers, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE6000A-US. (24) modules: Trina SolarTSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1980	11041-20000-06652	777 S FIGUEROA ST 39th Floor-41st Floor	90017	9	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	ADDRESS	34.04828	-118.26116	TI 39th to 41st floor.  Install new branch circuits.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1981	14041-10000-25442	16126 W WYANDOTTE ST	91406	6	186B141   772	2205027022	MR1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.20284	-118.48469	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 2661 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1982	19041-10000-33940	3905 S KEESHEN DR	90066	11	111B157   132	4235025023	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.00382	-118.42828	Plan check for a PV1 7.1KW DC / 4.8KW AC roofmounted system with (1) load center,  (20) Enphase Microinverters and modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1983	15041-10002-16645	9012 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	ADDRESS	34.23397	-118.55337	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE TO LIGHTING. UPDATED T24 FORMS. NO OTHER CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1984	18041-10000-31869	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015033	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Issued	10/25/2018 12:00:00 AM	ADDRESS	34.02557	-118.3665	Plan check for a fire alarm system located in a commercial building with (1) fire alarm panel, (4) power supplies and (308) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1985	19041-20003-13132			10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM			PC Approved	10/02/2019 12:00:00 AM	PIN	34.0220244	-118.33367049	10-02-2019 Changes to an approved set of plan, Changes include remove generator, reuse the existing 400A 480Volts 3 Phase 3 W  Service system to feed transformers and distribution boards, All changes shall apply to delta 7 only. Plan check only, permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1986	15041-20000-22577	15209 FRED WAY	91405	6	186B145  1132			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	PIN	34.20923845	-118.46445491	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1987	14041-10000-14143	9000 N RESEDA BLVD	91324	12	195B125   108	2769001022	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.23439	-118.53589	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT STARBUCKS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1988	18041-20000-36833	17457 W SUNBURST ST	91325	12	195B129    34	2768023014	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.23465	-118.51523	Plan check for a PV1 roof-mounted PV system. Systme size is 16.5 kWdc/15.41 kWac and consists of (2) 7.6 kWac-rated inverters, (50) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
1989	17041-10000-20475	3952 W WILSHIRE BLVD	90010	10	132B193    73	5092030006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.06148	-118.31302	PLAN CHECK FOR T24 ONLY FOR TI - BUILDING ON THE FIRST FLOOR (15' X 79') FROM RETAIL TO COFFEE SHOP (B) . TOTAL AFFECTED AREA = 1100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1990	15041-20000-02734	16116 W COHASSET ST	91406	6	186B141   287	2205023023	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.20651	-118.48425	TI TO AN EXISITNG SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING, NEW CONTROLS, AND NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2371.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1991	19041-20001-25289	6150 N LAUREL CANYON BLVD SUITE 140	91606	2	177B165  1100	2334011029	(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	10-31-2019 Changes to an approved set of plan, Changes include addition of new lighting in the area and electrical equipment relocation load on panel schedule has be revised. All changes has been clouded as delta 2. Plan check only, permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1992	19041-10000-28057	189 S THE GROVE DR SUITE-F90B	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	ENERGY PC ONLY , T. I. FOR NEW RESTAURANT (REMODEL OF EXISTING).  CHANGES FOR NEW SERVICE COUNTER ARE (E) KITCHEN/DINING/RR TO REMAIN. AREA OF SCOPE 1,700SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1993	16041-10000-38551	6200 W WILSHIRE BLVD SUITE 1008	90048	5	135B177   512	5088015021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.06295	-118.36347	T-24, PC FOR ENERGY ONLY.TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING FOR SUITE 1008. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1018 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1994	19041-10000-12334	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Apartment			04/04/2019 12:00:00 AM	02/14/2020 12:00:00 AM		Permit Finaled	10/27/2021 12:00:00 AM	ADDRESS	33.94571	-118.38857	INSTALL 1632 NEW FIRE ALARM DEVICES ON HOTEL INCLUDING 4 NEW FIRE ALARM PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1995	13041-10000-02906	380 W WORLD WAY SPACE 33	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Approved	02/05/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. PANDA EXPRESS AT LAX SPACE 33.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1996	18041-10001-05147	415 E MANITOBA ST	90293	11	093B153   117	4117030017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	33.95337	-118.44194	[[[CHANGES TO APPROVED SET TO SHOW EXISTING PV SYSTEM ON SITE PLAN AND SINGLE LINE DIAGARAM. PLANCHECK ONLY. ]]]Plan check for battery back up system to existing PV system. Install one power wall 2.0 with PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1997	15041-20001-36499	333 N KINGS ROAD	90048	5	138B173   283	5514010019	R1-1-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	34.07698	-118.37226	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 7.6kW and 26 modules. Standard plan is not being use.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
1998	17041-20001-00394	7500 N LANKERSHIM BLVD	91605	2	186B169   461	2316013003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM			PC Approved	08/07/2017 12:00:00 AM	ADDRESS	34.20684	-118.38758	Revisions to approved set.  Miscellaneous changes and change of feeder/branch ratings on SLD.  Approval for clouded revisions only.  (((Service upgrade 600 amps to an existing gym.  plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
1999	15041-20000-18914	10933 W ROCHESTER AVE SYSTEM 1	90024	5	132B153   743	4324005087	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.05602	-118.4436	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 43 KW. (160) 310W MODULES(3) SMA SB11000(1) SMA SB10000Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2000	12041-20000-09704	11900 W COURTLEIGH DR	90066	11	111B161  1000	4233019020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			04/27/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	33.99718	-118.41875	New 28 unit apartment building. Fire alarm variance was file. Plan check for power and energy, the building is 5 levels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2001	15041-10000-02656	149 S BRISTOL AVE	90049	11	132B137   550	4406011009	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.05547	-118.48834	Plan check for PV roof top. System size: 11.4kw with 3 strings and 46 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2002	13041-10000-08951	946 E 12TH ST	90021	14	123A211   196	5132013009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM			PC Approved	05/03/2013 12:00:00 AM	ADDRESS	34.03135	-118.24843	SINGLE STORY BUILDING.  3 RETAIL UNITS.  T24 INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2003	14041-20000-13458	8011 N WINNETKA AVE	91306	3	189B113   438	2107017181	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.2159	-118.57128	4.08KW PV1  roof-mounted system with (16) Trina Solar #TSM-255PA05.18 modules,  (1) Solaredge SE3800A_US inverter and Solaredge power Optimzer P300.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2004	16041-20000-04930	11511 W TENNESSEE AVE	90064	11	123B153   233	4260016005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.03484	-118.44331	PLANCHECK FOR POWER  FOR CAR SERVICE EQUIPMENT AND GARAGE. HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2005	18041-20000-01717	12746 W JEFFERSON BLVD space 2-2130	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	33.97756	-118.41709	ti to an existing commercial space.  adding new lighting new controls to new panels.  total new connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2006	14041-20000-10889	16234 W CHATSWORTH ST	91344	12	207B137   475	2679018003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Expired	05/19/2016 12:00:00 AM	ADDRESS	34.26454	-118.4862	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL TRANSFORMERLESS STANDARD PLAN. SYSTEM SIZE: 5 KW.(20) CANADIAN SOLAR CS6P 250(1) POWER ONE AURORA PVI 4.2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2007	16041-20000-39351	11601 W WILSHIRE BLVD 22nd Floor-Restrooms	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM			PC Approved	11/07/2016 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for energy only. TI to restrooms on 22nd floor of high rise building. New lighting (incl. emergency). 503sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2008	16041-10000-25757	4945 N EAGLE ROCK BLVD #B	90041	14	162A221   398	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.13606	-118.21531	PC FOR TITLE 24. TOTAL AREA 1959 SQFT. LIGHTING AND RECEPTECALES INSTALLED.(REF:16016-10000-15315)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2009	17041-10000-09444	10250 W SANTA MONICA BLVD #1940	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR FIRST TIME TI ""PENHALIGON'S""  IN WESTFIELD CENTURY CITY. SUITE 1940"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2010	17041-20001-28893	9900 N BALBOA BLVD	91325	12	201B133   127	2685009020	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.25067	-118.50215	"09-09-2019 Changes to an approved set of plan, changes include Panel ""B"" Changes to 600A and electric water heater, and revised load. All Changes has been cloudedFuture PV Sysytem under separate permit."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2011	14041-20001-35757	4827 N FULTON AVE Bld. 5E	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			03/20/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.15858	-118.42347	[[3/20/18 CHANGES TO APPROVED SET. DELTA 1 CHANGES ARE CLOUDED. ADDING SUMP PUMPS, PANEL HD, HOUSE BREAKER INCREASED TO 1000AMPS]]]]New 3 story apartment with 24 units and 2 level subterranean garage.  New 1600A service, panels, branch circuits, and lighting.  Plan check for power and energy.Note: variance to separate fire alarm plans submitted on 12/29/14.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2012	16041-20000-35067	6120 N YOLANDA AVE	91335	3	177B121   497	2127016018	MR1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.18132	-118.54025	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from office to sound studio/tenant improvement. Work includes a new 600-amp service and new distribution boards and loads. Total lighting area = 16,757 sq. ft.Note: Building application has been generated under 16016-20000-15152	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2013	15041-20000-32165	970 W 190TH ST SUITE 110	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	33.85812	-118.29302	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 110. 4077 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2014	15041-20000-36019	1401 N LONDONDERRY PL	90069	5	147B169   915	5559010012	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES - SUB STD STREET	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.09556	-118.38046	PLANCHECK FOR A  NEW SINGLE FAMILY DWELLING. 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2015	15041-10000-02682	110 E 22ND ST	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	33.72668	-118.27682	Plan check for power and title 24.  Total area = 24,709 sq. ft.T.I. to convert existing 1 story warehouse to brewery.  Electrical work consists of new power distribution board, new subpanels, and branch circuits for power and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2016	19041-10001-37903	1818 W 71ST ST	90047	8	102B193  1202	6016036018	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Apartment			09/20/2019 12:00:00 AM			PC Approved	03/04/2020 12:00:00 AM	ADDRESS	33.97522	-118.30968	(EXPEDITE FEE FOR)------->PC FOR PV SYSTEM, SYSTEM SIZE IS 35.52KW-DC, 25.2KW-AC. SYSTEM WILL BE MOUNTED ON THE ROOF OF A RESIDENTIAL APARTMENT UNITS. SYSTEM CONSISTS OF (96) HYNDAI MODULES WITH OPTIMIZERS, (2) SOLAREDGE SE7900H INVERTER AND (1) SOLAREDGE SE10000 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2017	10041-10000-11015	2413 S 2ND AVE	90018	10	123B189   436	5059026900	OS-1XL-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	01/28/2011 12:00:00 AM	ADDRESS	34.03459	-118.31905	CONSTRUCT A NEW SINGLE STORY RESTROOM FACILITY WITH STORAGE ROOM AND DRINKING FOUNTAIN; (2) STANDARD RESTROOM STALLS AND (2) ADA ACCESSIBLE STALLSplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2018	08041-10005-13153	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	Revisions to approved set based on Delta 5.   Install 2 @ 30KVA, 2 @ Panels and a new motor control center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2019	19041-10000-27509	18455 S FIGUEROA ST	90248	15	060B201    20	7339008034	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Closed	12/16/2021 12:00:00 AM	ADDRESS	33.86353	-118.28198	New distribution and power for (E) commercial building.  2500A main distribution board bus extension with lab/test equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2020	12041-10000-07553	20874 W KELVIN PL	91367	3	174B109   126	2149014020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.17598	-118.58737	PLAN CHECK FOR 6.540KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2021	17041-20000-20544	1124 N CITRUS AVE	90038	4	144B185   626	5532019019	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.0915	-118.33969	Plan check for fire alarm system. New fire alarm system for a commercial office. 1 FACP. 60 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2022	16041-10000-24900	1820 E INDUSTRIAL ST	90021	14	124-5A2171372	5164021121	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.03563	-118.23389	PC FOR POWER ONLY. SCOPE INCLUDES ADDITION OF 18 NEW PANELS LESS THAN 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2023	15041-20001-18697	15234 W VALLEYHEART DR	91403	4	168B145    38	2263017009	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2015 12:00:00 AM			PC Approved	06/29/2015 12:00:00 AM	ADDRESS	34.16107	-118.46513	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE 6.55KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2024	16041-20000-15934	2310 N CATALINA ST	90027	4	153B197   501	5588017026	RE11-1	Central	Hollywood	Los Feliz	Yes	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.11248	-118.29608	Plan check for a PV1 roof-mounted PV system. System size is 15.8 kWac and consists of (66) modules, (66) micro-inverters, and (2) load centers. (2) different module types are being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2025	15041-20000-37597	1017 N LAS PALMAS AVE	90038	4	144B185   896	5532026036	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.08943	-118.33642	PLANCHECK FOR POWER AND ENERGY. INTERIOR TI FOR FLOORS 1,2 AND 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2026	11041-10000-26029	600 E VENICE BLVD	90291	11	108B145  1790	4237001014	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	33.989	-118.4621	PLAN CHECK T24 ENERGY/EMERGENCY RESTAURANT/BAR TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2027	14041-20000-04065	22044 W RUNNYMEDE ST	91303	3	186B101   558	2023004003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.20542	-118.60761	Roof mounted PV system with 5.5KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2028	17041-30000-03149	23357 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.15806	-118.63423	Title 24 plan check.   Interior remodel of existing CVS store.  New lighting in restroom area and receptacles in photolab area.  Total area = 324 sq. ft.Building permit #17016-40000-01277	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2029	13041-10000-11284	710 N EL CENTRO AVE	90038	13	141B189   274	5534035018	(T)(Q)RAS3-1	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Apartment			05/01/2013 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.08386	-118.3243	pc for power and energy. ~28 typical units. methane buffer zoneNew privately funded 84 unit mixed use project.4 Stories Type VA fully sprinklered R2 occupancy with M Occupancy commercial over 2 levels Type I S2 Occupancy basement parking. Project utilizes housing incentives per Sec. 12.22.25 of the Zoning Code providing 4 Very Low Income units using Parking Option No. 1 (139 residential, 26 commercial parking spaces)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2030	18041-10000-07572	1820 N LAS PALMAS AVE	90028	13	150A185   262	5547003900	OS-1XL	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.10465	-118.33611	AT THE LAS PALMAS SENIOR CENTER, REPLACING INDOOR AND OUTDOOR LUMINAIRES WITH LED TYPES. NO CHANGES TO EMERGENCY LUMINAIRES AND EXIT SIGNS.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2031	18041-20000-11494	21418 W SHERMAN WAY	91303	3	183B105   182	2111028005	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.20085	-118.59835	ti to an existing commercial building.  addig new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2032	15041-10000-32122	21355 W SHERMAN WAY Space-7230	91303	3	186B105   631	2111029001	(T)(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	ADDRESS	34.20118	-118.5973	per inspector it needs a load calculations .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2033	17041-20000-37283	18313 W MINNEHAHA ST	91326	12	207B125   605	2731013047	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Re-Activate Permit	11/06/2018 12:00:00 AM	ADDRESS	34.26011	-118.5323	Note: $0.00 permit fee due to CA Senate Bill 1222.ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.3 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2034	19041-20001-14893	4758 W BONVUE AVE	90027	4	153B197   302	5588017008	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	34.11445	-118.29464	08-08-2019 Changes to an approved set of plans, Changes include point of connection on Main Service panel. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2035	10041-10000-25842	440 S VERMONT AVE UNIT #110	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	12/30/2010 12:00:00 AM		Permit Finaled	02/11/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	TI IN AN EXISTING RETAIL STORE IN UNIT #110. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2036	14041-10001-02364	881 W MIRAFLORES AVE	90731	15	021B197   551	7447020026	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	33.75272	-118.29635	][][EXPEDITED PER APPLICANT REQUEST ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH 200A MAIN SERVICE. SYSTEM SIZE IS 2.5 kW DC. (10) TRINA # TSM-250PA05.18 MODULES, (10) OPTIMIZERS OP300-MV, (1) SE3000 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2037	18041-20000-47847	334 E SUNSET AVE	90291	11	109-5A143  67	4286007021	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	33.99545	-118.47421	Plan check for fire alarm system, office building. Total fire alarm devices: 30 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2038	16041-20000-26082	643 N RADCLIFFE AVE	90272	11	126B125   468	4412014047	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.04225	-118.53093	Plan check for PV roof mounted system. System size: 8.6kW with 25 AC Modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2039	18041-20000-06783	5440 N TROOST AVE	91601	2	174B169  1207	2348001037	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.1697	-118.38649	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to a place of assembly. Total lighting area = 3,073 sq. ft.Note: Building application has been generated under 17016-20000-33236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2040	14041-20000-14718	721 N MARTEL AVE	90046	5	141B181   434	5526010005	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.0843	-118.35123	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.18KW AC USING MICROINVERTERS. USING ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2041	18041-20000-10884	16830 W VENTURA BLVD Ste 501	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/14/2018 12:00:00 AM	ADDRESS	34.15886	-118.50032	Tenant improvement to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2042	10041-10000-00565	7651 S CENTRAL AVE	90001	9	099B209    95	6023021028	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	Public Safety Only			01/12/2010 12:00:00 AM			PC Info Complete	01/12/2010 12:00:00 AM	ADDRESS	33.97007	-118.25659	Plan check for new FACP and dditional fire alarm devices (smoke/heat dectectors) to existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2043	15041-20000-39137	14012 W CALIFA ST	91401	2	174B153    35	2246015020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.17748	-118.43834	PV1, roof mounted solar panel, 10kW AC system(50) modules: #KU2656ZPA(2) inverters: PVI-5000-OUTD-US-Z-A(1) Load Center 125A  Standrad plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2044	14041-10000-24972	7120 N REMMET AVE	91303	3	183B105   332	2111027032	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.19982	-118.60014	this is a new fire alarm system, for a school , 1 story. 29 devices and 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2045	15041-10000-16256	921 S CROCKER ST #C-21	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	Energy plan check for retail T.I, new lighting only. Total area is 1555-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2046	16041-10000-23506	1331 N FIGUEROA PL	90744	15	033B201    19	7412009010	[Q]R3-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Harbor City		2943.02	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	33.78929	-118.28357	Permit fee is $0.00 due to Senate Bil: 1222PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 40.25KWac. SOLAR SYSTEM IS FOR BLDG 6 & 7.(147)MODULES(7)INVERTERS(1)200A PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2047	13041-20000-07727	8629 N WOODLEY AVE	91343	12	195B137   956	2689024022	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.22748	-118.48551	Plan check for addition of main disconnect to 600A service and 50A breaker for house panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2048	13041-20000-14708	19334 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.23457	-118.5549	RENOVATION OF TENANT SPACE FOR BEAUTY SALON. INCOMING BARBER SHOP. PC FOR T24 ENERGY ONLY. TOTAL AREA 2275 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2049	15041-10000-08435	15 E PALOMA AVE 1-58	90291	11	109-5A141 137	4286021002	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Apartment			03/23/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	33.9937	-118.47885	PV2 19.6KWroof-mounted system with (86) Polycrystalline Solar Module Q.PRO-255, (4)4.2 Growatt inverter interconnecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2050	16041-20000-27156	12035 W WATERFRONT DR 4TH FLR	90094	11	105B161  1201	4211011029	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	33.98233	-118.40556	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  NO NEW LOADS, RELOCATE OF EXISTING CIRCUITS. PLAN CHECK FOR ENERGY AND EM LIGHTING.  TOTAL SQUARE FOOTAGE 4164 ON THE 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2051	19041-20001-04642	12300 W 1ST HELENA DR pv1	90049	11	129B141   246	4405039011	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM			PC Approved	02/26/2019 12:00:00 AM	ADDRESS	34.0519	-118.47793	expeditepv1install roof mounted pv system sized 18.3KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2052	14041-10000-25686	2121 S AVENUE OF THE STARS 2150/2175	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	Title 24 plan check  on a T.I office in a high rise building.  total remodeling area is 6704 SQ feet in suit 2150 and 2175.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2053	18041-20000-37403	1344 N MALTMAN AVE	90026	13	144A203   342	5427028013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.08738	-118.27822	PV1.  Install 20.3 kW roof mounted grid tied PV system.  (55) modules with 7.6 and 10 kW rated string inverters.$20.20 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2054	17041-10002-38219	7208 S BROADWAY	90003	9	102B201   947	6031002003	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	33.97436	-118.2781	PC for T24 only for new lighting for retail TI. Total area is 2446sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2055	14041-10002-23259	1225 S VERMONT AVE	90006	13	129B197   894	5078028006	C2-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			06/29/2015 12:00:00 AM			PC Approved	06/29/2015 12:00:00 AM	ADDRESS	34.04827	-118.29188	((6/29/2015))REVISIONS TO AN APPROVED SET OF PLANS.  VERIFICATION OF LOAD CALCULATIONS FOR DERATE OF THE MAIN SERVICE BREAKER.  PV2.  Install 14.84 kW utility-interactive PV system on apartment building rooftop.  3ph 120V/208Y transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2056	17041-20001-41123	19823 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	33.85048	-118.28713	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 36 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2057	06041-10008-09913	1633 N LA BREA AVE	90046	4	147B181   287	5548008010	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Apartment			04/01/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Closed	12/09/2011 12:00:00 AM	ADDRESS	34.10058	-118.34527	DELTA 14 REVISIONS TO APPROVED SET OF PLANS- CHANGES TO INTERIOR LIGHTING SYSTEM; NEW FACADE LIGHTING  ; INCREASE BY ONE SET OF CONDUCTORS FOR THE FEEDERS TO THE UNIT PANELBOARDS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2058	14041-20000-01248	6108 N RESEDA BLVD	91335	3	177B125   614	2124008025	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.18103	-118.53581	Change to lighting in an existing massage parlor.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2059	17041-10000-11445	1555 E NEWTON ST	90021	14	121-5A213 342	5130020021	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.02538	-118.24168	PLAN CHECK FOR POWER AND ENERGY FOR T.I. EXISTING OFFICE WAREHOUSE REMODEL. PLAN CHECK INCLUDES CONNECTING TO AN EXISTING DISTRIBUTION BOARD, AND ADDITION OF 4 NEW DISTRIBUTION BOARDS, AND PANELS. TOTAL AREA: 25,834.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2060	15041-10000-38817	8862 S FIGUEROA ST	90003	8	096A201   204	6038003021	RD2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.95634	-118.2825	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(13) KYOCERA 2656 MODULES(1) ABB PVI-3.0 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2061	13041-10000-19707	600 W 7TH ST	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.04728	-118.25685	permit to be pulled at EPC counter only. PC for energy only.NON STRUCTURAL TENANT IMPROVEMENT; DEMO, NEW PARTITIONS, PROJECT IS COMMON MAIL ROOM FOR BUILDING  242 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2062	19041-10000-10938	14120 W MARGATE ST	91401	4	171B153   239	2248019014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.16733	-118.44086	[e-plan] Fee is $3.97 per AB1414. New 11.4kW AC Roof mounted PV system (40 modules), (40) P400, with a single inverter tied in at main service panel.  Main breaker to be derated to 175A.  <derating main breaker to 175A is under separate express permit>	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2063	15041-10000-40374	829 E 3RD ST	90012	14	129A215   260	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.04601	-118.23547	TI, ICE CREAM SHOP. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2064	15041-20000-38563	20153 W RUNNYMEDE ST	91306	3	186B113   404	2114006015	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.20602	-118.57268	PV1. Install roof mounted PV system sized 8.2 kW. Interconnected with main service panel.(38) Kyocera KU265 Modules(1) Fronius Primo 8.2-1 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2065	13041-20000-08443	9725 S LAUREL PL	90002	15	093A217   176	6046019903	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2421.00, 2422.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	33.94758	-118.2311	Replace existing 400 ampere circuit breaker with new 600 ampere circuit breaker to match existing manufacture and AIC rating, and install one new 4 inch EMT conduit.   No loads added to service at this time.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2066	13041-10000-05959	1709 W EL REY ROAD	90732	15	015B193   148	7559024009	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Expired	04/01/2015 12:00:00 AM	ADDRESS	33.73936	-118.31317	PV1 ROOF MOUNTED SOLAR INSTALLATION ON SINGLE STORY BUILDING USING MICROINVETER STANDARD PLAN. SYSTEM SIZE IS 3.46 KW. [MODULES: CENTRO SOLAR # E250 |||| INVERTER ENPHASE # M215]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2067	16041-20000-06882	10156 N WOODALE AVE	91331	6	204B153   514	2647018003	RS-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.25539	-118.44351	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2068	17041-10000-21522	13181 W MINDANAO WAY	90292	11	105B153   104	4212004007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	33.98449	-118.43785	Title 24 plan check.  T.I. to existing restaurant space.  One new subpanel with new lighting and receptacles.  Total area = 5,043 sq. ft.       Building permit #17016-10000-03999	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2069	19041-10001-29163	9472 N SANDUSKY AVE	91331	6	198B153   187	2642017001	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM			Corrections Issued	08/16/2019 12:00:00 AM	ADDRESS	34.24208	-118.43287	08/16/2019 Changes to an approved set of plans. Changes include the revision of module layout and addition of PV subpanel. _____________________________________________Plan check for a PV1 7.6kw AC / 8.85 KW DC roofmounted system. Scope inlcudes (1) inverter, (29) modules and optimizers interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2070	12041-10000-08174	1521 S LIVONIA AVE	90035	5	129B169   405	4305012016	R1-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Expired	06/11/2014 12:00:00 AM	ADDRESS	34.05177	-118.38658	New 4.3kw rooftop photovoltaic system for an existing single family residence.  System uses both Enphase M215 Microinverters and a single normal inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2071	17041-20000-18951	1111 S GRAND AVE	90015	14	127-5A207 332	5139021***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			06/06/2017 12:00:00 AM			PC Info Complete	06/28/2017 12:00:00 AM	ADDRESS	34.04144	-118.26266	"Plan check for energy only. Remodel interior lobby for high rise building. New lighting (including emergency). 1,560sqft.""COMPLY WITH DEPARTMENT ORDER effective date04/05/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2072	18041-10000-47854	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	33.98722	-118.47211	INSTALLATION OF NEW FIRE ALARM CONTROL PANEL FOR EXISTING FIRE ALARM SYSTEM.NEW WIRELESS CELLULAR COMMUNICATOR IN THE BASEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2073	19041-10000-11373	11232 W VANOWEN ST	91605	2	180B173    24	2319007017	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1232.06	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.19374	-118.3762	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2074	16041-10000-17928	1000 W ELYSIAN PARK AVE LEVEL 1-CORRIDOR	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			PC Info Complete	08/03/2016 12:00:00 AM	ADDRESS	34.07196	-118.24719	PC for  energy only. Installing new lighting going from HID to LED light fixtures on level 1 corridor of Dodger Stadium. Adding (2) new panels. Newly connected load is less than 400 Amps. Total sqft = 1393.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2075	14041-20001-17420	10110 N WEALTHA AVE	91352	7	204B173   252	2528017009	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	08/06/2014 12:00:00 AM	ADDRESS	34.25401	-118.37528	Fee is 0.00 base on Senate bill 1222 from 2012.  6KW regular plan ,PV1 roof-mounted system with (24) Enphase M215 microinverters and Solarworld Sunmodule SW250 Poly modules. Main service is 400 Amp rated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2076	14041-10000-35578	1060 N VISTAGRANDE DR	90272	11	132B121   382	4420025019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.05639	-118.55056	6kW roof mounted PV system including (24) Enphase M250 microinverters, and a load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2077	19041-20000-39465	10425 W SUNSET BLVD	90077	5	141B153   226	4362021014	RE20-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	09/30/2022 12:00:00 AM		Permit Finaled	12/05/2023 12:00:00 AM	ADDRESS	34.08015	-118.4371	2-STORY 27,000 SQUARE FT SINGLE FAMILY DWELLING WITH A 2,000 AMP, 208/120V 3 PHASE SERVICE. 500KW OPTIONAL BACKUP GENERATOR, PANELS, EQUIPMENT, ETC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2078	19041-20000-41825	953 E 3RD ST 1st & 2nd-FLR	90013	14	129A217   161	5163006020	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.04613	-118.23335	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2079	17041-20000-45899	13063 W VENTURA BLVD	91604	2	165B161   932	2375020012	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.14601	-118.4181	Plancheck due to lost plans. Plan check for energy only. TI to (e) 2-story office building w/ basement. New lighting (incl. emergeny) - 5,610sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2080	19041-20000-04694	13540 W DESMOND ST	91331	7	210B157    70	2523005007	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	11/01/2021 12:00:00 AM		Issued	11/01/2021 12:00:00 AM	ADDRESS	34.27544	-118.42731	Change of use from manufacturing to hydroponic agricultural enterprise.  Plan check for power and energy. Building permit application number 19016-20000-03256	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2081	15041-10000-42738	17383 W SUNSET BLVD STE A220	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	TI FOR OFFICE SPACE. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2082	16041-10000-29118	923 S WESTWOOD BLVD	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.06323	-118.44558	PC for energy only to existing building. Removing wall partition to combine two tenant spaces into one retail space. Adding new lighting and power. Adding a new panel rated at 100 amps. Total sqft = 5299	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2083	12041-20000-28427	13550 W PAXTON ST	91331	7	210B157   162	2535002014		North Valley				1043.20	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.27276	-118.42714	Install 1500 gallon UST fuel additive tank with associated piping, monitoring, and venting in a Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2084	18041-10000-02459	5435 N SAN FERNANDO ROAD WEST	90039	13	165B201    70	5593008010	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.15137	-118.27531	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2085	14041-20000-10959	21708 W MALDEN ST	91304	3	192B105   214	2779026012	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.22491	-118.60218	Roof mounted PV system with system size 3.75KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2086	19041-10000-31698	3435 W WILSHIRE BLVD #800	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.06194	-118.29866	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT PORTION OF 8TH FLOOR OFFICE SPACE (NO CHANGE IN USE). SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 2571 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2087	16041-10002-07723	5227 N VINCENT AVE	90041	14	163-5A225 178	5669018010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.14226	-118.20245	Change to approved set: show underground trench for DC connection, revise inverters location, revise single line diagram. New Load Center.<<PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (34) MODULES, (1)3.0 KW INVERTER AND (1) 7KW INVERTER. TOTAL SYSTEM SIZE IS 10KW.>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2088	15041-10000-24553	1963 S VERMONT AVE	90007	1	126B197   950	5075038003	CM-2	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.03849	-118.29177	FULL PLAN CHECK  FOR A COMMERCIAL BLDG WITH NEW 600-AMP SERVICE AND 6-PANELS. TOTAL  48-CIRCUITS, 9-EQUIPMENT AND 5822-SQ FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2089	16041-10000-06162	695 S VERMONT AVE #110	90005	10	132B197   178	5094008026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM			PC Info Complete	02/22/2016 12:00:00 AM	ADDRESS	34.06016	-118.29183	TI on (E) restaurant #110. PC for T-24 only. Total area: 5050 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2090	15041-10001-10037	7224 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	33.97406	-118.2913	11/23/15CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 5 AND DELTA 2. SCOPE INCLUDES EMERGENCY LIGHITNG AND FIXTURE PLACEMENT. (((TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 18034)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2091	19041-20000-36732	5727 N CANOGA AVE BLDG 19	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.17529	-118.5978	PV2 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING APARTMENT BUILDING #19. SYSTEM SIZE IS 4.32 KW DC/3.973 KW CEC AC. SCOPE OF WORK CONSISTS OF (12) PV MODULES, A 100A PANEL, AND A 3.8 KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2092	18041-10002-03105	5101 S EDSEL AVE	90066	11	105B161   409	4221011059	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Expired	09/11/2023 12:00:00 AM	ADDRESS	33.98559	-118.4163	SUPPLIMENTAL FOR THE ENERGY STORAGE SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2093	17041-10000-34870	17134 W OTSEGO ST	91316	5	171B133   494	2258011011	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	11/18/2017 12:00:00 AM	ADDRESS	34.16356	-118.50692	PC FOR PV SYSTEM. TOTAL OF 50 MODULES. USING 16.75 KW AC WITH AC MODULES.permit fee is zero according to senate bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2094	11041-10000-17992	350 S FIGUEROA ST Ste 370	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	34.05438	-118.2549	T.I. High rise building.  Remodel of light fixtures in suite 370 (Phase I).  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2095	13041-10000-25101	309 E RUSTIC DR	90065	11	123B129   812	4410012012	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Expired	10/19/2015 12:00:00 AM	PIN	34.03062173	-118.51661237	PV1.  Install 5.832 kW AC roof-mounted solar array, interconnect with main service panel.  Microinverter standard plan submitted.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2096	18041-20003-37378	7701 N WOODLEY AVE	91406	6	186B137   423	2205010905	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	34.20948	-118.48389	"07-31-2019 Changes to an approved set of plan, change include remove load  Hangar receptacle on distributions, increase Hangar receptacle, update overcurrent protection and feeder size,  equipment relocation. All changes has been clouded as delta ""4"" and ""5""plan check only, no new equipment install.**********Previous Work Description**********************4/18/2019changes to an approved set of plans.  changes noted delta 3 only.  changes to remove MTS and add additional circuits.plan check for power.   ((((Plan check for power only. Project site is an existing commercial building (existing hangar at Van Nuys airport). Project scope is a new 800 amp serive at 4.8KV feeding a 2,000-amp switchgear which will re-feed existing distribution equipment and loads.))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2097	13041-10000-30844	6255 W SUNSET BLVD 15TH FLOOR	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR T24 ENERGY ONLY. HIGHRISE 15TH FLOOR RESTROOMS. 342 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2098	13041-10001-27078	1901 1/2 S BUNDY DR	90025	11	123B149   379	4259019012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM			PC Approved	08/08/2014 12:00:00 AM	ADDRESS	34.03435	-118.45789	changes to approved set of plan. pc for removing some fa devices only. 08/08/2014.<<<fa for parking structure. 1 facp 1 ann, 3 power supply, 120 devices>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2099	19041-20000-11504	7538 W VALMONT ST	91042	7	204A197   529	2563007024	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.25225	-118.29676	INSTALLATION OF NEW ROOFTOP PV SYSTEM FOR A EXISTING SFD. SYSTEM SIZE IS 8.45KW DC/10KW AC/7.74KW AC CEC. SCOPE OF WORK INCLUDES (26) HANWHA Q CELL PV MODULES WITH P370 OPTIMIZERS, AND A SE10000H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2100	18041-10000-04145	10201 W PICO BLVD BLDG 99-4th FLR	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	T-24, PC for energy only. Tenant improvement to an existing office building on the 4th floor. Scope includes replacing lighting fixtures. Total affected area is 1675 Sq. Ft. B#17016-30000-24950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2101	15041-10000-08896	583 N GLENDALE BLVD	90026	13	138A207   334	5404013017	C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.07036	-118.26164	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNECTED WITH MSP.(((((APPLICANT HAS NO CREDIT MEANS TO PAY FOR ONLINE PERMITING)))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2102	08041-10002-23810	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	REVISIONS TO APPROVED SET OF PLANS.EACH OF A PAIR OF 4 PAIRS OF SUBSTATIONS IS REPLACED WITH A 1000KVA SUBSTATION; 2KA BUS DUCT WAS REMOVED; AND THE SUBSTATION IS REFED FROM THE SWITCHBOARD; LOAD SCHEDULES WERE REVISED ; SOME LOADS WERE MOVED AROUND TO OTHER PANELBOARDS; INVERTER WAS REPLACE WITH INDIVIDUAL EM  BATTERY PACKS; RESTROOMS ON THE 1ST LEV WERE RELOCATED TO MAKE ROOM FOR SUBSTATIONS The 4160V substation is existing to remain.  Demolish all electrical work except the service and install all new electrical equipment for a 2-story commercial building.  Plan Check for Power and energy. (2005 Code)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2103	12041-20000-11316	10133 N SAN FERNANDO ROAD	91331	6	204B161   502	2623032027	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.25424	-118.40986	7-eleven new TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2104	10041-10000-24563	811 W WILSHIRE BLVD #700	90017	9	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	03/04/2011 12:00:00 AM	ADDRESS	34.04973	-118.2584	Ti in an existing office. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2105	10041-10000-15869	811 W WILSHIRE BLVD 6TH FL	90017	9	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.04973	-118.2584	TENANT IMPROVEMENT FOR OFFICE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2106	14041-10000-10650	11600 W TUXFORD ST	91352	6	192B169   306	2632023046	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.22447	-118.38481	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2107	14041-10000-22500	11240 W OLYMPIC BLVD	90064	11	126B153  1021	4260020016	M2-1, PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.03863	-118.44015	Tenant improvement in retail space plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2108	12041-10000-20685	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.05436	-118.25543	Plan check T24 Energy/Emergency lighting for new corridor light fixtures on 3rd floor . Existing area controls and branch circuits. No T24 Energy plan check for the guest rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2109	18041-10000-42403	2001 S HOOVER ST	90007	1	126A201   282	5056028031	C2-1VL	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.03786	-118.28426	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2110	14041-10000-12721	12751 W MILLENNIUM	90094		102B161  1175	4211033020							Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM			Verifications in Progress	07/24/2014 12:00:00 AM	ADDRESS	33.9761	-118.41651	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT RETAIL OCCUPANT. 8300 SQRFT TAILORED METHOD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2111	19041-20001-36746	5727 N CANOGA AVE BLDG 10	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	10/14/2020 12:00:00 AM	ADDRESS	34.17529	-118.5978	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2112	18041-10000-08130	1200 S GRAND AVE	90015	14	126A207   131	5139023039	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.03989	-118.26331	TI IN THE GARAGE , ENCLOSING SPACE TO CREATE A MAINTENACE ROOMPLAN CHK IS FOR TITLE 24. Permit was issued under 18041-20000-15578	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2113	18041-10000-48177	16332 W NORDHOFF ST	91343	12	198B137  1048	2688002010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.2355	-118.48838	PLAN CHECK FOR ROOF MOUNTED 3.0KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) WITH 17 MODULES USING P320 OPTIMIZERS CONNECTED TO EXISTING 3.0KVA PV SYSTEM USING COMBINER BOX	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2114	15041-20000-14961	5501-5505 W PICO BLVD	90019	10	129B177   824	5085030001	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.04914	-118.35756	EXPAND RESTAURENT TENANT TO EXISTING SPACE. CHANGE OF USE OS EXISTING SPACE TO NEW DINING AREA FOR RESTAURENT. NEW LIGHTING. NOT OVER 100 ACCUPANTS PER BUILDING. THIS IS PLAN CHECK FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2115	15041-10000-40697	10604 W BRADBURY ROAD	90064	5	126B161   701	4318041018	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Expired	01/05/2018 12:00:00 AM	ADDRESS	34.03744	-118.4176	PV1, INSTALL 8.48 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: KYOCERA KU2656ZPA(1) INVERTER: FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2116	10041-10000-17090	141 N UNION AVE	90026	13	135A207    44	5159008024	RD1.5-1	Central	Westlake	Greater Echo Park Elysian	YES	2083.00, 2084.00	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	05/24/2011 12:00:00 AM	ADDRESS	34.06576	-118.26534	New fire alarm system. Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2117	11041-10000-23112	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM	10/28/2011 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.09676	-118.29487	1 fire alarm panel and 4 devices. back bone instalation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2118	17041-20000-43711	20710 W BLACKHAWK ST	91311	12	204B109   119	2706014013	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.25815	-118.58456	pv1install roof mounted pv system sized 6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2119	17041-10000-20165	924 N VIRGIL AVE	90029	13	144A201   244	5539007029	R3-1	Central	Hollywood	East Hollywood	YES	1914.10	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.08846	-118.2867	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2120	15041-10000-10658	9110 S CENTRAL AVE	90002	9	094-5A209 133	6043008900	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	33.95357	-118.25622	NEW FIRE ALARM SYSTEM 75 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2121	12041-20000-25689	5539 N RIVERTON AVE	91601	4	174B173  1109	2416014026	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.17108	-118.36581	Plan check for power. New 1200A service upgrade with new feeders going to service. Fees may change once panel schedules are included; panel sizes were estimated based on breaker sizes. Studio.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2122	12041-20004-01921	10643 W SUNSET BLVD Bldg #1	90077	5	138B153   103	4362009012	A1-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.07571	-118.44485	Modification to previously approved set of plans for BLDG #1.          <<<Plan check for new 2000A service and distribution boards. Existing charter school buildings. Consolidating multiple services into one service. No new loads added.  (1 of 3 - This Permit 12041-10000-01921 is for building #1, Permit #12041-10001-01921 is for Building #2 and Permit #12041-10002-01921 is for Building #3)>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2123	13041-10000-05928	2049 S CENTURY PARK EAST SUITE 2460	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER ONLY.  PLAN CHECK FOR TITLE 24 ON A HIGH RISE OFFICE BUILDING TENANT IMPROVEMENT. SUITE 2460.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2124	15041-20000-11898	12446 W OSPREY LANE Unit 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.97949	-118.41001	Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (8) modules, and (1) inverter. This is Unit 2 of 3.Note: PV solar clearance shall apply to the three units under this PCAM number.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2125	13041-10000-34374	12936 W WENTWORTH ST	91331	6	195B161   138	2628010020	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Expired	01/19/2016 12:00:00 AM	ADDRESS	34.23466	-118.41433	PV1, install 2 kw DC roof-mounted solar array for a 2-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. (8) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2126	15041-20000-37317	9668 N PINE ORCHARD ST	91331	7	201B161   969	2624013***	RD5-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.24563	-118.40982	Plan check for PV roof mounted system. System size: 3.0kW with 17  modules and 1 inverter(3.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2127	15041-10000-16351	627 S WITMER ST	90017	1	132A207   284	5143015020	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.05441	-118.26653	EXTENDING PARKING LOT TO BE ONE. ADDING NEW 14FT POLE-MOUNTED LUMINAIRES (24 EA) USING THE SAME TYPE LAMPS-1LAMP;2LAMPS;3LAMPS LUMINAIRES;NON-SALES CANOPY  INCLUDED. title 24 PLAN CHK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2128	14041-10000-04066	8701 S LINCOLN BLVD	90045	11	096B161   737	4119026038	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	33.95847	-118.41793	This a parking structure  first floor, out door and indoor lighthing, according to the customer the area is 75000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2129	13041-20000-14352	235 S SAN PEDRO ST #A	90012	14	129A213   469	5161024***	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.0487	-118.2424	First time tenant in a mixed use building.  Beauty Salon.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2130	15041-20001-31972	809 S BUNDY DR 1-50	90049	11	129B141   411	4264010***	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			01/27/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.05	-118.47214	[1/27/16  CHANGES TO APPROVED T24 PLANS PER INSPECTORS REQUEST. PLANCHECK ONLY. ADDITION OF EMERGENCY LIGHTING IN CORRIDORS AND FIRE DOORS IN CORRIDORS]]]Title 24 plan check only.  Total area = 6,884 sq. ft.Installation of new lighting in hallway areas of three story low rise apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2131	12041-10001-15337	8421 S REGIS WAY	90045	11	096B161   432	4113005037	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	33.96119	-118.41478	Plan check for new 3.12KW roof mounted photovoltaic system using Solaredge transformerless inverter and DC-DC Power box. Existing permit #12041-20000-15337 for solar-modules and inverter.   Misc Permit on this application is for the DC/DC Converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2132	15041-20000-15709	5881 W 75TH ST	90045	11	102B169   241	4104008015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	33.9733	-118.38545	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A center-fed MSP.Derating main breaker to 150A. System size: 3.1kW. (12) 275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2133	19041-10000-33783	17554 W DORIC ST	91344	12	222B129   185	2601045009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.30326	-118.51665	pc for pv-1 , system consists of 26 panels with optimizers. 1 - SE5000H inverter. System connected to a new 125A solar ready panel. System size is 7.41KWdc an 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2134	18041-20000-23272	1457 N VAN NESS AVE Roof	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.09731	-118.31598	Plan check for Title 24 only. Project site is the roof of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,200 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2135	17041-10000-18422	5340 S ALLA ROAD 2nd floor	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	33.9773	-118.42567	Title 24 plan check.  T.I. to office space in existing two story building.  One new subpanel with lighting and receptacles.  Total area = 5,141 sq. ft.       Building permit #17016-10000-14387	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2136	17041-10000-25085	213 S HOBART BLVD	90004	10	138B193  1398	5517013010	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.07074	-118.30563	PC for new 20HP elevator in church. Plan check due to assembly occupancy type.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2137	15041-10000-40900	10866 W ART ST	91040	7	201B173   268	2542025010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.24841	-118.36746	PV1 11.4KW AC roof mounted system with (35) SunPower X21-345 moulde, (1) combiner box and (1) Solaredge SE11400A inverter interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2138	12041-10000-18289	205 N SERRANO AVE	90004	10	138B193   614	5517010025	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2012 12:00:00 AM			Corrections Issued	01/11/2013 12:00:00 AM	ADDRESS	34.07554	-118.30686	New 3.84kw, rooftop, Photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2139	16041-20001-24744	1901 S SEPULVEDA BLVD	90025	5	126B153   287	4323025039	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	ADDRESS	34.04414	-118.44168	6.20.2017 - Plan check for modifications to approved set. Update sheet E2.01 to show exit signs (w/battery backup). Changes clouded in pen.======PLANCHECK FOR POWER AND ENERGY. CHG OF USE FROM RETAIL TO SELF STORAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2140	16041-20002-07499	20334 W CHASE ST	91306	3	192B113   215	2781023001	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	PIN	34.22441031	-118.57682679	Revisions to approved set.  Main breaker derate to 150 A.  (((Plan check for the addition of a PV1 roof-mounted PV 3 kWac system onto an existing 9 kWac PV system, for a total system size of 12 kWac. Addition consists of (1) inverter, (8) modules, and (1) load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2141	12041-10000-12725	4282 N PERLITA AVE	90039	13	159B205   771	5594010035	(T)(Q)RD2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.13083	-118.26788	Plan check for new roof mounted 6.2KW photovoltaic system for an existing single family dwelling with Enphase M215 Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2142	17041-10000-03434	255 E ADAMS BLVD	90011	9	120A207   122	5127036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.02379	-118.2657	PC for outdoor title 24. Removign HID fixtures and repalcing them with new LED ones. Area: 14,350 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2143	10041-20000-20919	1660 W 3RD ST	90017	1	133-5A205 153	5153008014	C2-1	Central	Westlake		YES	2091.01	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.06052	-118.26744	fire alarm dialysis center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2144	13041-20001-15949	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	(((CHANGES MADE TO APPROVED SET OF T24. CHANGED FIXTURE TYPES))))change to lighting and receptacles for an existing on-story car rental office.  Load less than 400 amps per Engineer.  PLAN CHECK ONLY for Energy, NO Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2145	15041-10002-12895	3640 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.01993	-118.37802	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE RELOCATION OF LOADS TO NEW PANELBOARD. REVISION TO FLOOR PLAN FOR EGRESS LIGHITNG. UPDATED TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2146	14041-10000-02442	1102 S WESTERN AVE	90006	10	129B193   647	5080010001	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.05064	-118.30888	T24 PART 6 ENERGY PLAN CHECK FOR COFFEE SHOP. PROJECTED IN LIGHTING SCOPE OF WORK IS APPROX. 1349 SQ FT AREA. SCOPE OF WORK < 400A. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER. ALL WORK WILL BE INTERIOR,  PER APPLICANT.note: permit fee already calculated under inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2147	14041-20000-34085	1833 W HILL DR	90041	14	163-5A225  66	5669002004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Expired	01/04/2017 12:00:00 AM	ADDRESS	34.14359	-118.20757	PV 1 roof mounted system size: 3.8kW and 1 inverter and 21 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2148	16041-10000-24198	331 N CARMELINA AVE	90049	11	135B137   634	4405010008	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.06256	-118.48529	New 2-story s.f.d. with an attached 3-car garage and partial basement. New 600 Amp service. PC for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2149	15041-10001-02875	8927 W ST IVES DR	90069	4	144B169   662	5560018003	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.09381	-118.38753	((2/24/2015- ORIGINALLY SUBMITTED FOR SERVICE ONLY HOWEVER IT REQUIRES A FULL PLAN CHECK. THIS IS A PLAN CHECK ONLY APPLICATION.))Plan check for power. Scope of work is the upgrade of a 400-amp rated main service panel to a 600-amp rated main service panel. All other panels and loads are existing to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2150	17041-10000-14941	6059 N VAN NUYS BLVD	91401	6	177A151    79	2241027001	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Issued	05/05/2017 12:00:00 AM	ADDRESS	34.18037	-118.44899	PC for energy only, Outdoor Title-24. Removing hid fixturs and replacing them with new LED. Area: 56,000 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2151	19041-10000-24397	1147 W 37TH ST 1-5	90007	8	120B197  1108	5040030016	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.0211	-118.29311	NEW FIRE ALARM IN A 5 UNIT CONDOMINIUM CONSIST OF 1 FIRE ALARM PANEL, 1 COMMUNICATOR, 1 ANNUNCIATOR AND 37 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2152	19041-20000-44418	15430 W GREENLEAF ST	91403	5	166-5A145  35	2283018026	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.15244	-118.4705	PV PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 15.12 KW DC/12.6 KW AC. SCOPE OF WORK CONSISTS OF (48) PV MODULES WITH OPTIMIZERS, A 5 KW AND A 7.6 KW INVERTER, AND (2) SUB PANELS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2153	19041-20000-41222	19243 W SANTA RITA ST	91356	3	171B117    82	2163011017	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.16773	-118.5524	PLAN CHECK FOR NEW 40.5 KWH ENERGY STORAGE SYSTEM FOR EXISTING SFD WITH PV SYSTEM. SCOPE OF WORK CONSISTS OF (3) 13.5 KWH BATTERIES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2154	12041-10000-26935	920 N VIGNES ST	90012	14	132A217    28	5409017900	PF-1XL	Central	Central City North			2060.20	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Closed	06/28/2019 12:00:00 AM	ADDRESS	34.05723	-118.23154	600 AMP 277/480V, 3PHASE TEMP. SERVICE FOR CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2155	10041-10000-04049	448 S HILL ST #706	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM			PC Info Complete	03/05/2010 12:00:00 AM	ADDRESS	34.04896	-118.25139	T.I. for a high rise building at 7th floor.  Install general lighting.  Plan check for energy only.  Branch circuits are under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2156	14041-10000-26257	4728 W FOUNTAIN AVE	90029	13	147B197  1134	5540018020	[Q]C2-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.09526	-118.29279	PV2, 31.4kw AC roof-mounted system in a commercial property; including (130) Hanwha HSL60P6 modules, (3) Fronius IG Plus  inverters interconnecting through (2) load sub panels. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2157	12041-10000-01028	8601 S LINCOLN BLVD	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	33.95939	-118.41943	INTERIOR TENANT IMPROVEMENTS OF A VACANT SUITE AT PLAYA DEL ORO FOR LA FITNESS SPORTS CLUB WITH STATE OF THE ART HEALTH CLUB TO INCLUDE NEW FREE WEIGHTS, CIRCUIT, TRAINING EQUIPMENT, AEROBICS ROOM, SPINNING ROOM, <SEE COMMENTS>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2158	18041-10000-03264	630 W 5TH ST	90071	14	130-5A209 151	5151025905	PF-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.05063	-118.25491	FULL PC FOR POWER AND ENERGY FOR AN EXISTING LIBRARY/MEDIA SPACE. SCOPE INCLUDES A NEW 225A PANEL, NEW CIRCUITS, AND NEW LIGHTS. TOTAL  A-OCCUPANT LOAD > 100.  TOTAL AFFECTED AREA IS 1986 SQ. FT. B#16016-10000-30871	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2159	18041-20000-35990	7320 N WOODLAKE AVE Ste 190	91307	12	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Info Complete	09/20/2018 12:00:00 AM	ADDRESS	34.20263	-118.63189	Plan check for power and energy. Project site is a tenant space (optometrist) in an existing medical office building. Project scope is a tenant improvement. Total lighting area = 400 sq. ft.Note: Building application has been generated under 18016-20000-27414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2160	19041-10000-04949	6151 N RADFORD AVE Bldg B	91606	2	177B165  1102	2334011031		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Apartment			02/13/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/05/2023 12:00:00 AM	ADDRESS	34.18246	-118.3924	Full plan check for a 5-story 481-unit apartment building (BLDG B) :  Scope includes (4) 3000 Amps 120/208v and 277/480v services with a total of (20) typical residential unit and the total area of 108,000-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2161	17041-10000-29925	8500 W BEVERLY BLVD #758	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	RETAIL TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2162	18041-10000-19379	20630 W LEMAY ST	91306	3	180B109   349	2148019003	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.19091	-118.58201	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.67KWdc / 6.00KWac.(23)MODULES-JINKO SOLAR 290 WATT MODULES(23)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE6000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2163	14041-10001-27475	13484 W BAYLISS ROAD	90049	11	138B133   397	4492013008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.07275	-118.50409	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. [[[PV1, INSTALL 10.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SSERVICE PANEL.(40) MODULES: KYOCERA# JD255GX-LFB3(2) INVERTERS: SOLAREDGE SE3800A-US-ZB-U]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2164	18041-10000-05828	269 S MARIPOSA AVE	90004	10	135B197   154	5518007030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.06948	-118.29938	PC for new FA system for 7 story apartment building. Installing 1 FACP, 1 annunciator, 9 RPS and 392 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2165	15041-20001-20683	10815 N CANOGA AVE	91311	12	207B105   101	2722019034	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.26693	-118.59752	Expedite per applicant request[[[[[[Plan check for PV roof mounted system. System size: 7.6kW with 1 inverter(7.6kW) and 26 modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2166	15041-10000-03555	1030 N AMALFI DR	90272	11	129B133   305	4425011005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.04748	-118.50883	Plan check for PV1 roof mounted 9.69kW system  with 38 modules and 2 inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2167	16041-30001-00489	8735 N WHITE OAK AVE	91325	12	195B129   362	2768012010	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	ADDRESS	34.22967	-118.52026	Expedite fees only.     Addition of roof mounted solar PV array to existing roof mounted solar PV system.  Total system size = 9 kWac (5 kWac new + 4 kWac existing).  Two inverters total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2168	15041-20000-34034	13691 N GAVINA AVE #545	91342	7	225B165     2	2580017007	(T)(Q)RD6-1, (T)(Q)RD6-1-K, A1-1-K, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Expired	11/08/2017 12:00:00 AM	ADDRESS	34.31924	-118.40195	PV1. ROOFMOUNTED SYSTEM. SYSTEM SIZE:  3.5 KW . MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2169	14041-20000-18817	11901 W KATHYANN ST	91342	7	216B169    87	2531029012	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.28483	-118.39225	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2170	17041-30001-43149	847 N VIA DE LA PAZ #101	90272	11	129B125   735	4412004022	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	ADDRESS	34.04612	-118.52753	03-27-2018 Changes to an approved set of plan. Changes include remove down lights and replace with track lighing and relocate down lights. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2171	13041-10000-33694	1115 S WALL ST UNIT A	90015	14	124-5A209  91	5145023036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.03613	-118.25465	PLAN CHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 684 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2172	19041-10000-30143	325 N FICKETT ST	90033	14	127-5A225  60	5180008011	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			08/02/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Permit Finaled	03/29/2023 12:00:00 AM	ADDRESS	34.04489	-118.20613	NEW 3-STORY TOC 22 UNIT APARTMENT BLDG.BULDING PERMIT: 19010-10000-00794	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2173	11041-10000-17492	8500 W BEVERLY BLVD #646	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I. OF AN (E) RETAIL SPACE WITH AN (E) ADA COMPLIANT-UNISEX RESTROOM; DEMO OF (E) NON-STRUCTURAL WALLS, (E) STOREFRONT, (E) INTERIOR FINISHES; (E) A.C.T. & GYP BOARD CEILING TO REMAIN; ADD (N) NON-NONBEARING  WALLS TO CREATE FITTING ROOMS & STORAGE ROOM; (N) STOREFRONT, (N) INTEIROR FINISHES, (N) MILLWORK & (N) BULKHEAD   AND NEW SUSPENDED CEILING LATTICES; NO CHANGE IN USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2174	13041-10000-12139	9301 N TAMPA AVE #218	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	07/29/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT TI- BONEFISH GRILL. SUITE #218	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2175	18041-10000-28259	631 N NORTH MAIN ST	90012	14	132A215    37	5408012906	PF-1VL	Central	Central City	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.0575	-118.23876	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2176	14041-10000-04026	4581 W BRAZIL ST	90039	13	165B201   200	5593010018	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.14692	-118.27513	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2177	18041-20000-04956	715 N CYPRESS AVE	90065	1	145-5A219 385	5453020024	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.09134	-118.22351	plan check for a roof mounted PV system for a commercial building. Plan check includes 12 modules with p370 power optimizers, and Solaredge SE3800. 3.8KVA system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2178	16041-20000-26373	1211 S 3RD AVE	90019	10	129B189   674	5081015007	RD1.5-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.04948	-118.31929	PV1.  Install 3 kW AC roof mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2179	17041-20001-28130	1260 S VETERAN AVE	90024	5	132B149   167	4324003020	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.05654	-118.4465	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on apartment.(5) 7.6kW ungrounded inverters (38kW total system size).(150) 340W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2180	15041-10000-20759	600 WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	ADDITION OF A BREAKROOM/LOUNGE  AREA  AT THE ALSKA AIRLINES OFFICESPLAN CHK IS FOR TITLE 24 ; NOTE THAT THIS PLAN REVIEW INCLUDED THE OFFICE AREAS APPROVED ON 15041-10000-09906	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2181	11041-10000-15697	6101 S MAIN ST	90003	9	105B201   701	6005019001	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	05/22/2012 12:00:00 AM	ADDRESS	33.98407	-118.27411	T.I.  First time tenant.  New coin laundry to occupy space in a one story building.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2182	17041-10000-15056	1431 E 22ND ST	90011	9	118-5A211 101	5119028009	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM			Reviewed by Supervisor	05/19/2017 12:00:00 AM	ADDRESS	34.01977	-118.24947	PC FOR ROOF MOUNTE PV SYSTEM SIZE 10.4 KWAC SYSTEM INCLUDE TWO  5.2KW INVERTERS WITH 38 MOUDULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2183	14041-20000-28537	23501 W BALMORAL LANE	91307	12	183B093   243	2028023001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.19831	-118.63958	PV1 SFD. TOTAL SYSTEM SIZE 5.5KW AC USING 22 MODULES. USING ENPHASE M250. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2184	15041-20000-24141	6237 N LE SAGE AVE	91367	3	177B093   179	2035007038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.18426	-118.64156	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2185	17041-20000-41971	420 E 3RD ST UNIT#600	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM			PC Info Complete	11/28/2017 12:00:00 AM	ADDRESS	34.04686	-118.24182	PLANCHECK FOR POWER AND ENERGY. Tenant improvement and change of use from (e) office tenant space to (n) medical office tenant space.   (6,665 s.f.). SUITE 600BUILDING PERMIT # 17016-30000-26200	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2186	15041-20000-16222	8250 N VENTURA CANYON AVE	91402	6	192B157   706	2301002068	RA-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Issued	05/28/2015 12:00:00 AM	ADDRESS	34.22121	-118.42865	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE FROM 400 AMPS TO 600 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2187	12041-10000-26681	10801-10807 N SAN FERNANDO ROAD Bldg C	91331	7	207B157   309	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Info Complete	11/26/2012 12:00:00 AM	ADDRESS	34.26635	-118.42259	"Methane mitigation submittal - Building 'C' Restoration of building. Interior and Exterior remodel. (Buildings A through D were submitted together application numbers are: (A) 12041-10000-26679, (B) 12041-10000-26680, (C) 12041-10000-26681, (D) 12041-10000-26682),   <<Per applicant's request, Mr. Jose Delgado, the status was changed to ""Plan Check Only"".>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2188	13041-10001-01422	380 WORLD WAY T18	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Info Complete	03/07/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	DELTA ONE CHANGES TO PLAN. FULL POWER AND ENERGY.  DUTY FREE SHOP BLOCK T18 ON LEVEL 4 IN LAX.Fire alarm variance was submitted	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2189	19041-10000-53516	14000 W RIVERSIDE DR	91423	4	168B153   487	2269025031	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.15735	-118.43783	Energy plan check for a retail, change of use. Scope includes new lighting and equipment with a total lighting area of 890-SQ FT.(((CHANGE OF USE FOR PORTION OF  (E) RETAIL SPACE TO SMALL RESTAURANT (886 SF) WITHIN (E) COVERED MALL BUILDING)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2190	17041-10000-39813	12830 S FIGUEROA ST	90061	15	081B201   298	6132015001	[Q]C2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.91561	-118.28252	Remove outdoor HID Fixtures and replace it with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2191	15041-10000-00242	1200 S GRAND AVE	90015	14	126A207   131	5139023039	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.03989	-118.26331	Methane gas detection system with (19) devices and (1) panel in the level-3 of a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2192	10041-30000-04963	7411 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM			PC Info Complete	03/18/2010 12:00:00 AM	PIN	33.94363002	-118.42513364	Plan check for power for new feeder, xfmr, and d/c to supply existing panel HP-AA #08041-30000-09780. No underground penetration.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2193	16041-10000-13035	725 S FIGUEROA ST 6TH FLR	90017	14	129A207   336	5144009093	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			PC Info Complete	05/04/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	FULL PC FOR POWER AND ENERGY FOR AN EXISTING COMMERCIAL HIGH RISE BUILDING ON THE 6TH FLOOR. SCOPE INCLUDES NEW LIGHT AND RECEPTACLES FOR AN OFFICE SPACE. NEW CONNECTED LOAD >400A. PANELS ARE EXISTING TO REMAIN.  TOTAL AFFECTED AREA IS 3819 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2194	18041-10000-29209	1 W WORLD WAY	90045	11	090B165    93	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM			PC Approved	10/04/2018 12:00:00 AM	PIN	33.94415688	-118.4024579	Vanilla Shell for Retail space in LAX Terminal 1 Consession.T-24 Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2195	13041-10000-08461	634 S SPRING ST 5TH FLOOR	90014	14	127-5A211  51	5144001016	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.04504	-118.25156	T24 FOR TI ON 5TH FLR OF 2,230 SQ. FT.  HIGH RISE BUILDING. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2196	13041-10000-11441	6300 W ROMAINE ST	90038	4	144B185   960	5533020023	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.08878	-118.32903	New fire alarm system , six story , tenenat at the first level the rest is a parking structure	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2197	14041-20000-23748	13032 N ANGELES TRAIL WAY	91342	7	228B161   360	2580001001	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.30923	-118.40436	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WOTH MSP.STANDARD PLAN CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2198	13041-10000-18951	3500 N MANDEVILLE CANYON ROAD	90049	11	153B133    66	4490021002	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2013 12:00:00 AM			Reviewed by Supervisor	07/22/2013 12:00:00 AM	ADDRESS	34.11142	-118.49981	PV1. 1 STORY HOUSE. GROUND MOUNTED. 33 PANELS - 3 STRINGS (MAX POWER CS6X ).  10.065 KW PV SYSTEM ( SUNNY BOY AMERICA SB9000TL-US 240V) TRANSFORMERLESS. UNGROUNDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2199	19041-10000-00548	10434 N SEPULVEDA BLVD #A2b	91345	7	207B145   699	2649019033	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Closed	09/08/2022 12:00:00 AM	ADDRESS	34.26038	-118.46701	FULL PC FOR FIRST TIME TENANT. SCOPE INCLUDES NEW PANEL ( 225A), LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1200 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2200	17041-10000-12192	17300 W VANOWEN ST	91406	6	180B133    28	2229008005	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.19373	-118.51025	PC for energy only, Outdoor Title 24. Remove HID fixutres and replace them with LED. Area:  22,650 SQft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2201	13041-20000-10616	8700 N LAUREL CANYON BLVD	91352	6	195B165   704	2634038018	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Expired	06/10/2015 12:00:00 AM	ADDRESS	34.2277	-118.39899	solar single family 7.5 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2202	13041-10000-16744	100 UNIVERSAL CITY PLAZA 2282-02	0	4	162B177   344	2424044010	C2-1, PB-1	South Valley				1437.00	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM			PC Approved	06/24/2013 12:00:00 AM				REMODE;L PRIVATE OFFICES ONLYPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2203	18041-10000-40441	11121 N SEPULVEDA BLVD	91345	7	210B145    90	2664007902	QC2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Issued	11/19/2018 12:00:00 AM	ADDRESS	34.27261	-118.46782	PLAN CHECK FOR EV CHARGING STATIONS (3 LEVEL TWO CHARGERS AND 1 DC FAST CHARGER) CONNECTED TO EXCTING 2000A DISTRIBUTION SYSTEM - CONNECTED LOAD ABOUT 100A USING 800A EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2204	15041-10001-26417	13132 W CREWE ST	91605	2	183B161   656	2327010013	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.19654	-118.41929	PV1 ROOF MOUNTED SYTEM FOR A SINGLE FAMILY HOME. (1) INVERTER: 11.4 KW, (48) MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2205	19041-20000-53921	1521 W 8TH ST	90017	1	130-5A205 141	5142023004	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM			PC Info Complete	06/28/2022 12:00:00 AM	ADDRESS	34.05207	-118.27111	FULL PLAN CHECK FOR NEW MIXED USE COMMERCIAL APARTMENT BUILDING. NEW 2500A SERVICE WITH NEW DISTRIBUTION EQUIPMENT, LIGHTING, AND POWER LOADS. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 42855 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2206	14041-20001-26215	8734 N WHITE OAK AVE	91325	12	195B129   364	2768013013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.22967	-118.51986	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 17.2KW AC USING MIVROINVERTER. USING ENPHASE M250. TOTAL OF 70 MODULES. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2207	16041-20000-33769	13241 W WEIDNER ST	91331	7	210B157   114	2534002033	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.2743	-118.42265	Remove existing hid light fixtures and replace with led fixtures outdoors.  plan check for energy only.  total square footage 21250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2208	16041-10000-04101	3156 E CAZADOR ST	90065	1	150A217   192	5456015011	R2-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.10548	-118.23248	PV1, rooftop solar installation 3kW system.(8) SC-265(1) PVI-3.0-OUTD-S	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2209	15041-10001-04270	7401 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	33.94379	-118.42359	Changes to approved set: change of lighting fixture and supply voltage for luminaires to 480V.  (((Title 24 plan check only.  Total area = 25,200 sq. ft.Installation of 2 new light poles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2210	16041-20002-14747	1108 S LOS ANGELES ST	90015	14	126A209   262	5145021022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.03808	-118.25716	THIS IS SUPPLEMENTAL TO APPROVED SET OF PLANS. TOTAL SCOPE OF WORK TO INCLUDE SERVICE UPGRADE, TENANT 102 BUILD OUT AND REVISE 3 RESTROOMS. THIS APPLICATION IS FOR TENANT 102 FLOOR PLAN AND TITLE 24.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2211	14041-20001-12624	12056 N GERALD AVE	91344	12	216B137   164	2609029051	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.28967	-118.49194	Expedite per customer requestPV1. 6KW roof-mounted system with (24) Trina Solar #TSM-250PA05.18 modules,(1) Solaredge # SE6000A-US inverter, and (1) SolarEdge Power Optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2212	16041-20001-37509	17030 W GUNTHER ST	91344	12	213B133   175	2607014010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.2831	-118.50343	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (30) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2213	13041-10000-35647	6007 N MELVIN AVE	91356	3	177B117   647	2153023001	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.17953	-118.56028	PV1, Install 11.75 kW DC roof-mounted solar array on a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (47) Modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2214	18041-10001-22533	1846 W 46TH ST	90062	8	111B193   517	5015003011	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.00178	-118.31295	Changes to an approved set of plan. Changes include revised main panel to 200A main panel top feed. All Changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2215	10041-10001-25118	1200 S SANTA FE AVE	90021	14	123A217   315	5166007011	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.02944	-118.22979	"PLAN CHECK POWER AND ENERGY FOR REVISION TO APPROVED PLANS. ADD LIGHTING AND POWER TO EACH TENANT. MANUFACTURING/WAREHOUSE TO 53 FUTURE MANUFACTURING SPACES. COMPLY WITH DEPARTMENT ORDER effective date11/18/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2216	19041-20000-33022	676 N SPRING ST	0	1	133-5A215 212	5408013025	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Info Complete	08/22/2019 12:00:00 AM	PIN	34.05922278	-118.2378601	TENANT IMPROVEMENT FOR RETAIL TITLE 24 ONLY. TOTAL AFFECTED AREA 3926 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2217	15041-20000-24361	16507 W NORDHOFF ST	91343	12	198B137   978	2676023024	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.23586	-118.49183	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system. Using 300W power optimizers (one per module).(16) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2218	12041-20001-22048	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM			PC Approved	10/25/2012 12:00:00 AM	ADDRESS	34.06371	-118.3703	Changes to approved set of plans. Title 24 energy only, no changes to emergency lighting. Tenant Improvement of 15th floor & partial 14th floor. (Removing and adding load. Connected load over 400 Amps)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2219	15041-20000-28657	221 N FIGUEROA ST 6th Floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM			PC Approved	08/31/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	Title 24 plan check only.  Total area = 20,248 sq. ft.  T.I. to existing commercial office highrise building.  Less than 400 A new installed load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2220	13041-20000-13848	4760 W SUNSET BLVD	90027	13	147B197   733	5543015021	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.09788	-118.29343	PLAN CHECK FOR MEDICAL OFFICE. REPLACING 2 AC UNITS (AC-3 AND AC-4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2221	14041-20000-35052	16237 W NORDHOFF ST	91343	12	198B137  1007	2676015013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.23582	-118.48645	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(18) SUNPOWER SPR-327 MODULES(1) AURORA PVI-6000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2222	17041-20000-19649	18740 W KIRKCOLM LANE	91326	12	216B121    86	2870007007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Re-Activate Permit	10/04/2018 12:00:00 AM	ADDRESS	34.29229	-118.54173	Plan check for roof-mounted solar pv system with AC coupled battery backup system for SFD.10.4kW ungrounded system. (31) 325W pv modules. (1) 5kW Tesla Powerwall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2223	16041-10000-44820	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Closed	07/17/2018 12:00:00 AM	ADDRESS	34.18684	-118.3977	TI TO RETAIL SPACE. LOAD GREATER THAN 400A. PROVIDE 3 NEW PANELS, 4 NEW TRANSFORMERS AND CONNECT NEW LOADS TO EXISISTING PANELS. PROVIDE NEW LIGHTING AND TITLE 24. PC FOR POWER AND ENERGY. NOTE: NEW EMERGENCY LIGHTING WILL BE SUPPLIED BY UNIT EQUIPMENT AND IS NOT REQUIRED TO BE SUPPLIED BY EXISTING STANDBY GENERATOR.EXISTING GENERATOR IS NOT UNDER SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2224	14041-20002-02998	17825 W DEVONSHIRE ST	91325	12	204B129   154	2733001012	(T)(Q)RAS3-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			12/03/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	34.25768	-118.52255	revisions to an approved set of plans.  relocation of power equipment and emergency lighting bug eyes.NEW 3 STORY TYPE V-A 24 UNIT APT OVER TYPE I-A  BASEMENT GARAGE.  INSTALL NEW 1200A SERVICE, MAIN PANEL, SUBPANELS.  AND BRANCH CIRCUITS, AND LIGHTING.  PLAN CHECK FOR POWER AND ENERGY.  NOTE: T-24 CAL. IS REQUIRED FOR GARAGE AND COMMON AREAS.  ADDITIONAL PLAN CHECK FEE IS REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2225	18041-20002-23252	22441 W HARTLAND ST	91307	12	183B101   703	2024029010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM			Corrections Issued	02/27/2019 12:00:00 AM	ADDRESS	34.19474	-118.61627	02/27/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to reflect field conditions. Existing PV production meter has been added to plan set.02/11/2019 Changes to an approved set of plans, changes include addtion of 2 disconnect to each of the Tesla Battery. All changes has been clouded. Plan check only.*****Original Work Description*****Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (2) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2226	13041-10001-12781	861 N LA CIENEGA BLVD	90069	5	144B173   404	4337002048	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.08698	-118.37659	(((4/1/2014- CHANGES MADE TO APPROVED SET. CHANGED GROUNDING ELECTRODE CONDUCTOR TO 3/0 AND ADDED WAREWASH BOOSTER AND RELOCATION OF LOADS. LOAD CALC TO BE VERIFIED. UPDATED FLOOR PLAN MISSING)))pc for power and energy. TI UPGRADE SERVICE FROM SEVERAL separate services TO 800A. EXISTING BLDG. RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2227	18041-10000-23886	1700 N NAUD ST	90012	1	136-5A219 129	5409002021	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	07/15/2021 12:00:00 AM	ADDRESS	34.06865	-118.22638	ENERGY PLAN CHECK FOR A  CHANGE OF USE FROM WAREHOUSE TO BREWERY AND STORAGE FACILITY. NEW BATHROOMS, OFFICES, AND WALK-IN COOLER - TOTAL AFFECTED AREA = 7508 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2228	12041-10000-08173	23460 W CALIFA ST	91367	3	174B093    23	2041004035	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.17716	-118.63853	New 16.8kw rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2229	14041-20000-35204	6330 W SAN VICENTE BLVD SUITE 200	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	34.06116	-118.36804	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS AND CIRCUITS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 800.  SCOPE OF WORK TO BE PERFORMED IN SUITE 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2230	19041-20001-22547	17624 W CORINTHIAN DR	91316	5	168B129   347	2290011045	RE11-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.15819	-118.51713	EXPEDITED PLAN CHECK FOR NEW PV AND ESS FOR EXISTING SFD. PV SYSTEM SIZE IS 13.86KW DC/13.23KW AC. ESS SYSTEM SIZE IS 27 KWH. SCOPE OF WORK INCLUDES (42) PANASONIC PV MODULES WITH (42) ENPHASE IQ7X MICROINVERTERS, (2) 13.5 KWH TESLA POWERWALLS, A ENPHASE AC COMBINER BOX, A 200A SUB PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2231	13041-20001-33851	9546 N MELVIN AVE	91324	12	201B117   617	2761007028	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			Reviewed by Supervisor	12/19/2013 12:00:00 AM	ADDRESS	34.24405	-118.56	((EXPEDITE FEES))PV1 LOW FREQ TRANSFORMER. TOTAL SYSTEM SIZE 15KWAC. 69 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2232	19041-20000-41575	10064 N LARWIN AVE 7	91311	12	204B101   403	2724002***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Apartment			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.25357	-118.6175	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING APARTMENT UNIT 7. SYSTEM SIZE IS 9.62KW DC/10KW AC. SCOPE OF WORK CONSISTS OF (26) PV MODULES WITH OPTIMIZERS AND A 10 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2233	12041-10000-21237	8495 W 3RD ST D104	90048	5	138B173   683	5511013021	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM			PC Info Complete	12/27/2012 12:00:00 AM	ADDRESS	34.07352	-118.37624	Ti for a restaurant. New branch ckt and panel. EPC is for power & energy.((((((((((((((((((THIS IS A CONTIONAL APPROVAL, CUSTOMER IS TO BRING THE DEMAND AND POWER FACTORS FOR ALL TENANTS DUE TO THE FACT THAT THE BOARD MAY BE OVER LODED. MZANDI 12-27-12)))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2234	14041-20000-33210	6926 N RUBIO AVE	91406	6	183B137   325	2225007020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.1964	-118.49556	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. Using 300W power optimizers.29 235W/250W (mixed) pv modules across two strings (14+15).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2235	17041-10000-15177	11601 W WILSHIRE BLVD 2000	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	Title 24 plan check.  Partial floor office T.I. to existing commercial highrise building.  Subpanels to remain existing.  New lighting and receptacles.  Total area = 4,970 sq. ft.     Building permit #17016-10000-10431	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2236	11041-10000-16023	1840 S CENTURY PARK EAST 9TH FLOOR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI, TO AN EXISTING OFFICE BUILDING ON THE 9TH FLOOR.  PLAN CHECK IS FOR ENERGY, WITH EMERGENCY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2237	14041-20000-26866	3718 W REVERE AVE	90039	13	156B209   215	5435007034	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.12153	-118.26027	PV1Install roof-mounted solar array on SFD, interconnect with existing subpanel. System size: 3.84kW.(16) EnPhase M250 microinverters(16) SunModule SW275 MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2238	16041-30000-27690	843 N VIA DE LA PAZ	90272	11	129B125   735	4412004022	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.04604	-118.52755	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,460 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2239	17041-10000-03449	20056 W SHERMAN WAY	91306	3	183B113    66	2135007020	C2-1-RIO, C2-1VL-RIO, QP-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Public Safety Only			02/02/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.20085	-118.57054	Plan check for Title 24 only in existing space. (N) Starbucks T.I. Newly connected load less than 400A. Total area: 2,289 sq ft.  B#:17016-10000-02356	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2240	17041-10000-37515	1400 N CAHUENGA BLVD	90028	13	147A187   280	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	08/19/2022 12:00:00 AM	ADDRESS	34.09641	-118.32933	FULL PC FOR POWER AND ENERGY. NEW 8 STORY HOTEL WITH RESTAURANT AT GROUND FLOOR (CORE&SHELL ONLY) AND TOP LEVEL AMENITY WITH THREE SUBTERRANEAN GARAGE BASEMENTS.  SCOPE INCLUDES A NEW 2500A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 27,500 SQ. FT. B#16010-10000-05898	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2241	16041-20001-22506	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Closed	06/20/2019 12:00:00 AM	ADDRESS	34.04403	-118.2199	"12/01/2017 Changes to an approved set of plans. All changes have been clouded and noted as Delta 1. MCB has been derated from 700 Amps to 500 Amps.*****Previous Work Description*****""$0 permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 132kW with 468 modules and 4 inverters(33.kW) connected to commercial BuildingNote: Applicant need to assign Building Name"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2242	16041-20000-19544	6610 N LONGRIDGE AVE	91401	8	093A195   206	6055017046	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.1907	-118.42136	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.5KW. STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2243	19041-20000-18121	20839 W PINECONE CIR 23	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.29591	-118.58824	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2244	13041-20000-04608	14625 W MAGNOLIA BLVD	91403	4	172-5A151 215	2249007006	R1-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			02/22/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	PIN	34.16516072	-118.45184274	New 30-unit condiminium complex.  1200 amp service.  Full Plan Check.  Variance to separate fire alarm has been paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2245	09041-20001-13276	15245 W BURBANK BLVD	91411	4	174B145   443	2243003011	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM			PC Approved	05/19/2010 12:00:00 AM	ADDRESS	34.17231	-118.46543	Revision to approved plan. Energy plan check arnie's restaurant. Outdoor lighting are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2246	19041-20000-40382	18449 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2247	17041-10000-04590	20209 W RINALDI ST BLDG A1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Closed	03/16/2021 12:00:00 AM	ADDRESS	34.27509	-118.57388	PC FOR POWER AND ENRGY. NEW  BUILDING A1, -SHELL ONLY  COMMERCIAL BLDG - 1 STORY + MEZZ,  SERVICE SIZE 2000A, 277/480 V, TOTAL AREA 8648 SQ FT.BUILDING IS PART OF A 13 BUILDINGS MALL. B# 16010-10000-06134PROVISIONS FOR INSTALLATION FOR FUTURE GENERATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2248	17041-10001-19298	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	05/21/2020 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	"DELTA ""3"", ""4"", and ""5"" CHANGES TO APPROVED PLANS. <<<New Fire alarm system at the ""Gateway"" Midfield Satellite Concourse of LAX. (4) panels, (311) devices>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2249	13041-10002-35575	1001 S OLIVE ST	90015	14	127-5A209 272	5139010009	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.04228	-118.25988	Change to an approved set, all equipment is to be fully rated.  Total 152 ckts were added to the plan (1 ckt per each residential unit), and minors lighting and receptacle being added and reloacted to the floor plan. Changes are clouded. delta 56(((PLAN CHECK FOR POWER AND ENERGY. NEW 7 STORY APARTMENT OVER RETAIL AND PARKING MIXED USE BUILDING. (2)  4000 AMP SERVICES.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2250	19041-10001-31947	3517 S SPEARING AVE	90732	15	009B189   300	7563025006	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	33.7217	-118.32324	---------------Expedite FeesPV1, New rooftop mounted system, system size is 15.295KWdc/12.8KWac. Scope of work is solar roof tiles roughly 1374 sqft, 2 central inverters (Salivia 7.6 TL and Salivia 5.2 TL),three new load centers (200A ,70A,200A), and two ESS (Tesla Powerwall)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2251	19041-20000-24693	1010 W JEFFERSON BLVD 114-115	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.025	-118.28726	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indorr energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2252	15041-10000-18731	12465 W OSPREY LANE 1-3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	33.97923	-118.41018	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'A'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'A' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2253	19041-30000-44090	11601 W WILSHIRE BLVD SUITE 1100	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for energy only, scope of work includes new lighting and receptacles. Total sq. ft. 1970.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2254	14041-10000-35543	633 W 5TH ST 2nd floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Expired	05/30/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project site is the 2nd floor of a high-rise building. Total lighting area = 3,204 sq. ft. Plan has been submitted for plan check per applicant's request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2255	18041-10000-41438	545 S FIGUEROA ST 13TH FLOOR	90071	14	130-5A209 126	5151022001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.0514	-118.2582	TITLE 24 ONLY FOR 544 SQFT ON THE 13TH FLOOR. SCOPE OF WORK INCLUDES LIGHTING FIXTURES AND EMERGENCY LIGHTING WITH 14 NUMBER OF LUMINAIRES IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2256	16041-20001-12644	8715 N TOBIAS AVE	91402	6	195B149   570	2653003123	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Apartment			08/23/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.2286	-118.45189	8/23/2018changes to an approved set of plans.  changes noted delta 2.  changes to unit feeder breakers and series rating combination.This is plan check only.(((Plan check for power and energy. Project site is a new 4-story, 27-unit apartment building. Total lighting area = 21,562 sq. ft.Note: Building permit has been pulled under 05010-20000-07064)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2257	16041-20000-04188	3731 W STOCKER ST SUITE 212	90008	8	114B185   738	5032022017	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.00657	-118.33812	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. BEST BUDDIES. SUITE 212 1248 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2258	11041-10000-06085	10345 W WILKINS AVE 1-16	90024	5	132B157    83	4327010012		West Los Angeles				2657.00	Electrical	Electrical	Public Safety Only			03/31/2011 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.06158	-118.42489	New fire alarm system for an appartment BLDG. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2259	15041-20001-03026	12481 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9791	-118.41047	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2260	14041-20000-28973	811 S CARONDELET ST	90057	1	132A201   143	5141025027	(T)(Q)C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM			PC Info Complete	02/04/2015 12:00:00 AM	ADDRESS	34.0564	-118.28261	PV2. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. 10KW AC.(25) PV MODULES(1) POWER ONE 10.0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2261	19041-10000-45020	11800 W OLYMPIC BLVD	90064	11	123B149   515	4259024006	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			Verifications in Progress	01/03/2020 12:00:00 AM	ADDRESS	34.03298	-118.44987	FULL PLAN CHECK FOR A 1200A NEW SERVICE WITH 208/120V SYSTEM, FEEDING A 1200A SWITCHBOARD THAT FEEDS VARIOUS SUBPANELS AND EXISTING ELEVATOR WITH A TOTAL AREA OF 28,375 SQ/FT.  (B# 19014-10000-03493)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2262	16041-10000-01763	4718 E HUNTINGTON DR SOUTH	90032	14	142-5A231 100	5213019014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.08536	-118.18229	PC for energy only to a tenant space with existing equipment. Scope of work includes new lighting and receptacles.  Total sq. ft. 1080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2263	13041-10000-25286	4501 W COLORADO BLVD	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	PLAN CHECK FOR NEW SWITCHBOARD AND  EQUIPMENT FOR BUILDING 1 AT BAXTER.REPLACE MECHANICAL AIR COMPRESSOR AND HEAT EXCHANGE EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2264	11041-10000-15276	10800 W PICO BLVD #341	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	09/27/2011 12:00:00 AM		Permit Expired	01/06/2020 12:00:00 AM	ADDRESS	34.04054	-118.4272	TI TO AN EXISTING RETAIL SPACE (#341) IN A SHOPPING MALL.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2265	14041-10000-01112	813 S UNION AVE	90017	1	130-5A205 153	5142017004	R3-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Apartment			01/14/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.05195	-118.27271	INSTALLATION OF NEW FIRE ALARM SYSTEM IN 3-STORY APARTMENT BUILDING. (1) NEW FACP AND 44 DEVICES. BUILDING IS FULLY SPRINKLERED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2266	14041-10000-22311	810 S FLOWER ST	90017	14	129A209   164	5144020040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.04692	-118.26018	T.I. to existing commercial space.  Total area = 950 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2267	13041-10000-06789	5510 S LINCOLN BLVD	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM	05/06/2013 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	33.97299	-118.43051	T24 for a remodeled cafeteria on the first story of a 4 story office building.  2615 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2268	18041-20001-05571	11838 W VENTURA BLVD	91604	2	162B169   275	2369027016	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	ADDRESS	34.14236	-118.39049	Tenant improvement for commercial restaurant space.  Plan check for Title 24 energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2269	15041-10000-38583	1150 S OLIVE ST #2400	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI TO 24TH FLOOR. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2270	13041-10001-29520	9736 N OAKDALE AVE	91311	12	201B113   526	2761020035	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.24729	-118.56675	Expedited RSES plan check per applicant request.((((PV1.  Install 4 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: power-one aurora pv1-3.6-ou td-s-us.  16 modules: Trina Solar TSM-250PA05.18))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2271	12041-10001-04872	8900 N DE SOTO AVE BLDG 106	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	Modification to previously approved set of drawings to install a new substation instead of transformer.  Applicant will provide a copy of the original approved set of drawings.                     <<<<PLAN CHECK FOR NEW INSTALLATION OF 400KW FUEL CELL IN BUILDING #106. INCLUDES MEDIUM VOLTAGE INSTALLATION. ROCKETDYNE>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2272	18041-10001-47486	10926 N COZYCROFT AVE	91311	12	210B109   251	2707025011	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM			PC Approved	12/22/2018 12:00:00 AM	ADDRESS	34.26908	-118.58137	PV1, EXPEDITE PER CUSTOMER REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2273	18041-10001-14938	5809 S MAIN ST	90003	9	108B201  1349	5101023014	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM			PC Approved	07/10/2019 12:00:00 AM	ADDRESS	33.98945	-118.27417	Change to approved set by updating the location of the service panel. All changes under delta-2 only.(((PC FOR NEW ONE STORY RETAIL AND COIN LAUNDRY BUILDING FOR POWER AND ENERGY. SCOPE INCLUDES NEW SERVICE 800A 120/240V WITH NEW SUBPANELS CIRCUITS AND EQUIPMENT .TOTAL AFFECTED AREA 11585 SQ.FT B#17010-10000-03955)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2274	14041-20000-22542	7414 N FAUST AVE	91307	12	186B097   608	2022012002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Expired	09/19/2016 12:00:00 AM	ADDRESS	34.20524	-118.62037	PV1. Install 7.65 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2275	15041-20000-27873	8545 N WISNER AVE	91343	6	192B145    92	2654023065	R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.2259	-118.46232	Plan check for a PV1 roof-mounted PV system. System size is 4.75 kWac and consists of (19) modules, (19) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2276	13041-20000-16317	8232 N WHITE OAK AVE	91325	12	192B129   323	2201001032	(Q)C2-1VL, C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.22023	-118.51841	T24 FOR CHANGE OF USE FROM RETAIL TO 7/11 CONVENIENCE STORE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. ENERGY ONLY PLAN CHECK. 2514 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2277	14041-10001-03070	835 W 40TH PL	90037	9	114B197   280	5019001010	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.01017	-118.28849	Expedited RSES plan check per applicant request.{{PV1, Install 2.5 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U(15) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2278	17041-20001-13788	8436 W 3RD ST GROUND FLO-OR	90048	5	138B173   809	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/13/2018 12:00:00 AM	ADDRESS	34.07301	-118.37448	02/01/2018 Changes to an approved set of plans. Changes have been made to the lighting floor plans (indoor and outdoor lighting). All changes have been made to the Title 24 compliance forms. There has been a change of engineering for the lighting portion of the project.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE (E) OFFICE TO RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2279	13041-10000-30339	5551 W HOLLYWOOD BLVD	90028	13	148-5A193 134	5544003049	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.1019	-118.31091	Vanilla shell build for tenant lease space. Add lighting and receptacles. Mixed used building, residential on the second and commercial on the first floor, single line diagram to be provided upon correction. total lighting to be 1530 sf area.  Building is part of a larger stand alone building. 120/208 3-p, 4W subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2280	13041-20002-36315	10210 N OAKDALE AVE CLASSROOM	91311	12	204B113   213	2726008001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	34.25596	-118.56656	Change to approve set of plan. Title 24  base on 2008 code.((((PLAN CHECK FOR POWER AND ENERGY. CONSTRUCT NEW CLASSROOM BUILDING CONSISTING OF SIX (6) CLASSROOMS AND THREE (3) GROUP STUDY ROOMS.  1 OF 2. BUILDING PC # 13010-10000-04112))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2281	17041-20000-36729	20313 W VALERIO ST	91306	3	186B113   570	2114010008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.20478	-118.57583	$0 permit fees due to senate bill 1222pv1install roof mounted pv system sized 13.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2282	18041-10000-42794	6075 W HARGIS ST Lot B	90034	10	123B173   898	5065005019	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.0326	-118.37653	"NEW ROOFMOUNTED 2.2KW PV SYSTEM WITH 7 MODULES ON SINGLE FAMILY HOUSE. LOT ""B"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2283	16041-10001-30989	4365 W PICO BLVD	90019	10	129B185  1009	5082016021	C4-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Issued	02/07/2017 12:00:00 AM	ADDRESS	34.04829	-118.33	01/27/2017 Changes to an approved set of plans. Changes include additional of 2 panels at 400A and 2 panels at 200A. Changes has been clouded as Delta 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2284	18041-10000-34693	3011 E PICO BLVD STE B	90023	14	118-5A223 104	5169004001	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.01862	-118.21515	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2285	17041-10000-43372	811 W 7TH ST 9th &-10th	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.04908	-118.25911	Energy plan check for the elevator lobby of the 9th and 10th Floor. Scope includes new addition lighting and  reconnecting to exisitng control.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2286	16041-10001-03312	136 E 75TH ST	90003	9	102B205  1421	6022004008	R1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	33.97204	-118.27254	PV1, PC only due to the reduction of 2 modules.  (8) modules and (1) Inverter-3.0 KW. Note: Fees were paid under express permit 16041-90000-03312.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2287	13041-20000-07312	1152 N VERMONT AVE	90029	13	144B197   446	5542028005	[Q]C2-2D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			Corrections Issued	03/21/2013 12:00:00 AM	PIN	34.09260869	-118.29134379	Remodel of existing space into a yogurt shop.  T-24 lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2288	19041-20001-21984	10461 N WYSTONE AVE PV1	91326	12	207B121   773	2728015021	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.26071	-118.54826	Revision to approved plans: change of UL 2703-listed racking system. $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2289	16041-10001-18847	2030 S HAUSER BLVD	90016	10	126B177  1459	5063025011	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.03806	-118.36057	PC FOR PV SYSTEM. ORIGINAL PERMIT ISSUED ONLINE. THIS IS PLAN CHECK FOR ENTIRE SYSTEM AND PERMIT FOR SOLAR ONLY SUBPANEL. THIS IS CHECKING FOR CHANGES TO ORIGINAL DESIGN SUBMITTED ONLINE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2290	14041-20001-30111	11849 N LOUISE AVE	91344	12	216B133   540	2606015018	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	34.28569	-118.51092	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.6KW INTERCONECTED WITH MSP.(48) KYOCERA KD255 MODULES(2) ABB INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2291	17041-10000-32350	3525 W 8TH ST	90005	10	132B193   572	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			09/11/2017 12:00:00 AM	03/28/2019 12:00:00 AM		Issued	03/28/2019 12:00:00 AM	ADDRESS	34.05782	-118.30714	METHANE DETECTION SYSTEM FOR METHANE LEVEL 5 ON (E) COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2292	18041-10000-22421	16127 W DEARBORN ST	91343	12	198B141   552	2671020010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.23761	-118.48366	PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 11.685KWDC /10.95KWACSCOPE INCLUDES 41 MODULES WITH OPTIMZERS AND CENTRAL INVERTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2293	14041-10001-02374	7435 W PALO VISTA DR	90068	4	156B177   338	2427014007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	PIN	34.1236675	-118.35627136	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 7.5 KW DC roof-mounted solar array on a TWO story house, interconnect with existing service panel. (1)Transformerless inverter: SOLAREDGE SE6000A-US-ZB-U(30) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2294	16041-10000-27162	11811 W SAN VICENTE BLVD	90049	11	129B145    52	4401017018	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.0532	-118.46895	PC FOR POWER AND ENERGY. PROPOSED 2-STORY OFFICE BLDG WITH LEVEL GARAGE PER SAN VICENTE SCENIC CORRIDOR.  800A SERVICE. TOTAL AREA 25821 SQ FT. ENERGY PLAN CHECK IS UNDER 2008 NEC CODE.  B# 13010-10000-03190.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2295	18041-10000-29637	21340 W DEVONSHIRE ST	91311	12	204B105   323	2747011061	QC4-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.25707	-118.59648	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2296	17041-10000-41121	555 W 5TH ST STE 210	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC INTERIOR TENANT IMPROVEMENT ON THE 2ND FLOOR (IN A HIGH-RISE BUILDING).SCOPE INCLUDES NEW PANEL CIRCUITS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 4565 SQ.FTB# 17016-10000-27109	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2297	14041-20000-31477	1925 S CENTURY PARK EAST FEDEX	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI TO AN EXISTING COMMERCIAL SINGLE STORY BUILDING.  RELOCATING EXISITNG LIGHTING USING POWER PANELS.  1523 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2298	10041-10000-03981	545 S FIGUEROA ST 5th-6th FL	90071	9	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	03/05/2010 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.0514	-118.2582	Plan check T-24 energy general/emergency lighting for locker room spaces on the 5th & 6th floor of existing high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2299	14041-20000-06795	14608 W GREENLEAF ST	91403	4	165A149   236	2276017002	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.1486	-118.45249	Roof mounted PV system size 5.232KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2300	13041-10000-09772	724 N EAST KENSINGTON ROAD	90026	1	136-5A211 162	5405023013	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Apartment			04/16/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.06887	-118.25159	PV2 MULTI FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 1.96 KW. NONSTANDARD PLAN. USING TRANSFORMERLESS INVERTER. SUBMITTAL PART IN SERIES 3 OF 3. USING 8 PANELS. LOCATION IN METHANE ZONE, NO UNDERGROUND WORK DONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2301	10041-10000-19444	4245 N LANKERSHIM BLVD	91602	2	165B177   832	2423022045	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM			PC Info Complete	12/06/2010 12:00:00 AM	ADDRESS	34.14719	-118.3642	New installation of a PV systen. 45.5 KW. (A new 1000 Amp main fuse disscont will be installed)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2302	19041-20000-19874	700 S FLOWER ST 1100	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Issued	05/30/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	T24 PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL OFFICE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 10,151 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2303	12041-20000-22820	2029 S CENTURY PARK EAST # 800	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24 and emergency lighting plan check for suite 800.  Field verify exit sign and emergency lighting circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2304	17041-10001-23336	11401 N PORTER RANCH DR BLDG 5	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	06/30/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 5 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 41 unit apartment with 1600 amp 208 volt service.       Building 5 of 10.  Type IV.       Building permit #17010-10000-02382	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2305	18041-30000-15566	801 S FIGUEROA ST 6th Floor-Corridor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the 6th floor cooridor of a commercial building. Project scope is a tenant improvement. Total lighting area = 1,650 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2306	18041-20000-46185	925 W 34TH ST 1ST-2ND Floor	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	PIN	34.02383917	-118.28572873	Plan check for Title 24 only in existing space, 1st floor lobby and 2nd floor office T.I. Total area: 3865 sq ft. B#18016-10000-20300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2307	19041-30001-02397	11766 W WILSHIRE BLVD #550	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Approved	02/07/2019 12:00:00 AM	ADDRESS	34.04804	-118.46227	02/07/2019 Plan check for Title 24 only. Project site is a tenant suite on the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,007 sq. ft.Note: Building permit has been issued under 18016-30000-40561*****Original Work Description*****EXISTING TENENT IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2308	17041-10000-42483	723 S ST ANDREWS PL 1-65	90005	4	132B193   446	5092028005	R4-2	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	Apartment			11/28/2017 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	10/15/2022 12:00:00 AM	ADDRESS	34.0587	-118.31137	PC FOR NEW 5 STORY, 65 UNIT APARTMENT OVER 1-STORY PODIUM AND 1-LEVEL BASEMENT PARKING FOR POWER AND ENERGY. SCOPE INCLUDES NEW 1600 AMP SERVICE 208/120 3 PH. TOTAL AFFECTED AREA 26555 SQ.FT. B# 17010-10000-02557	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2309	14041-10000-33435	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.22149	-118.43179	Energy plan check for a general medical office (reception area only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2310	17041-10002-42103	2832 S MEDILL PL	90064	5	126B165   975	4308017018	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.03841	-118.40078	Supplemental for 5kW battery backup unit. PV covered under 17041-10000-42103.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2311	19041-20000-31139	528 N HAYWORTH AVE	90048	5	141B177  1031	5527020014	R3-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM	12/02/2020 12:00:00 AM		Permit Finaled	01/25/2022 12:00:00 AM	ADDRESS	34.08086	-118.36252	600A 240/120V 1ph-3w service and distribution for multiple single family dwellings in small lot subdivision.  Plan check for power and energy.  Unit subpanels and branch circuit wiring permitted under individual dwellings' building combination permits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2312	11041-10000-10118	4703 W BEVERLY BLVD	90004	4	138B193   403	5522033012	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			05/17/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.07643	-118.31152	Title 24 energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2313	15041-10001-36349	2195 W 29TH ST	90018	10	123B189  1137	5052028015	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2015 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	34.0292	-118.31473	expedited per customer request. (((PV1 installation to single family home. Inverter: 3.8 kw. (12) modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2314	19041-10000-51860	741 E PICO BLVD	90021	14	123A211    71	5132012055	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.03226	-118.25258	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2315	11041-10000-19206	2268 N BETTY LANE	90210	4	153B165   394	4387013017	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2011 12:00:00 AM			PC Approved	10/20/2011 12:00:00 AM	ADDRESS	34.11354	-118.40569	SOLAR POWER SYSTEM. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.   SUBMITTAL 2  FOR COLLECTION OF EXPEDITE FEES ONLY. EXPRESS PERMIT PREVIOUSLY ISSUED.Permits are existing.  11041-10000-12611 and 11041-10001-12611	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2316	10041-20000-04001	725 S FIGUEROA ST 3rd fl.	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM			PC Approved	03/05/2010 12:00:00 AM	ADDRESS	34.04886	-118.26071	3rd floor t.i.Energy, emergencyRequest for modification to separate Fire Alarm system filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2317	18041-20000-15875	2323 S BENTLEY AVE 1-15	90064	5	126B153  1025	4322021***	R3-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.03837	-118.43536	Fire alarm control panel and annunciator replacement.  Cellular alarm communicator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2318	14041-20001-02357	5815 W SUNSET BLVD 2ND FLOOR	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.09822	-118.31613	(((pc for restamp of T24 pages. Applicant made changes to power but t24 was uneffected. not checking power. t24 retamp only. ))))PC FOR T24 ENERGY ONLY. TOTAL AREA 4816 SQ FT. EXISTING OFFICES NEW LIGHITNG. WORK DONE IN BUILDING B SECOND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2319	13041-20000-31312	925 W 34TH ST ROOM 286	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	PIN	34.02383917	-118.28572873	NO CHANGE IN USE. EXISTING DENTAL CLINIC WITH REVISED LOADS. PC FOR POWER AND ENERGY FOR DENTAL CLINIC. TOTAL AREA 847 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2320	13041-10000-14307	6840 N DE CELIS PL #17	91406	6	183B137   536	2225001***	[T][Q]RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Expired	06/29/2015 12:00:00 AM	ADDRESS	34.19497	-118.4944	PV1.  Install new 3.185 kW DC roof-mounted solar array, interconnect with main service panel.  {13 modules: Trina Solar TSM-245PC05/PA05.18} {Transformerless inverter: SolarEdge SE3000A-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2321	14041-10002-21358	2215 E ALCAZAR ST	90033	14	135A225     6	5202003019	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	34.06357	-118.20153	PLAN CHECK FOR DELTA 11 CHANGES AS CLOUDED ON PLANS. NEW CONNECTION OF IDF PANELS AND UPDATED AC SPLIT SYSTEM CIRCUITING. PLAN CHECK ONLY. PERMIT ALREADY COVERED UNDER MASTER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2322	15041-20000-19744	300 S GRAND AVE 16th-17th Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	Title 24. TI to existing high rise commercial building (office space). Plan check for energy only. Adding new lighting including emergency. Total sqft. 10,650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2323	11041-10000-03497	250 E MANCHESTER AVE	90003	9	097-5A205 350	6041016003	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	05/11/2011 12:00:00 AM	ADDRESS	33.95987	-118.27031	T.I.  EXISTING OFFICE SPACE.  ELECTRICAL PLAN CHECK FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2324	17041-20000-44181	10354 W WILSHIRE BLVD	90024	5	135B157   134	4327013006	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			12/08/2017 12:00:00 AM			PC Info Complete	01/24/2018 12:00:00 AM	ADDRESS	34.0674	-118.42721	Plan check for power only. Project site is an existing apartment building. Project scope is a service upgrade to 1,200-amps to accomodate a future HVAC project. No new load is part of this scope of work. New tenant panels are being provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2325	19041-20000-22840	2215 S WESTWOOD BLVD	90064	5	126B157   457	4322002025	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.04321	-118.43144	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2326	13041-10001-04233	12223 W SANTA MONICA BLVD	90025	11	126B145   755	4263027017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.04001	-118.46529	This is submittal two because of change to SLD of original plan.  Need to check power and energy , marked up plans and correction sheet originally by Nabil	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2327	18041-20000-25323	8201 N TOPANGA CANYON BLVD #3	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.21793	-118.6063	Tenant improvement to (E) commercial restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2328	18041-20001-39878	7639 N SOUTHBY DR	91304	12	189B089   442	2027038047	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.21052	-118.65237	Expedited plan check fee per applicant request. PV1.  Install a 19.5 kW DC roof mounted grid tied PV system.  (60) modules with 10 kW and 3.0 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2329	12041-10000-07400	14006 W RIVERSIDE DR Space #254	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	05/07/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	TITLE 24 AND EMERGENCY LIGHTING FOR PANDA EXPRESS IN THE FOOD COURT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2330	16041-20001-06626	10914 N DARBY AVE	91326	12	210B125   700	2715004019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.26864	-118.53368	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. ADDITION TO EXISTING SYSTEM. ADDED SYSTEM SIZE: 5.72KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2331	12041-10000-23245	10737 W NATIONAL PL	90034	5	123B161   827	4254001013	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.03056	-118.41788	PV1 - Roof mounted P.V. system (10.14KWdc).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2332	17041-20001-34316	11930 N CAPISTRANO LANE	91326	12	216B117    51	2872004015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	34.28949	-118.55189	Expedite fee. PV1.  Install 4.6 kW roof mounted PV system.  Center-fed connection.  (14) modules with (1) 4kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2333	16041-10000-45307	7227 N TAMPA AVE	91335	3	183B117    35	2116018026	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.20191	-118.55379	T-24 TO A MESSAGE PARLOR ADD 6 WALL LIGHTS 4 SWITCHES RELOCATE, PC ONLY PER INSPECTOR'S CORRECTION. PERMIT NUMBER UNDER 16041-10000-41159	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2334	13041-20000-28617	9667 N CANOGA AVE PV2	91311	12	201B105   188	2746015001	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.24588	-118.59911	New 170KW AC ROOFTOP PV system for an existing commercial building. ( $0 permit fee is due to the 2012 Senate Bill No. 1222)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2335	12041-20000-25972	21255 W BURBANK BLVD 3rd floor-Suite 300	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM			PC Approved	10/30/2012 12:00:00 AM	ADDRESS	34.17432	-118.59446	T-24 lighting plan check for remodeled office space on the third floor.  Non-structural, interior remodel to 2,300 sq. ft. tenant space in existing office building to create offices, 732 sq. ft. exercise room, and shower facilities, including:  non-bearing partitions; ceilings; and finish work.  Exercise room occupancy not to exceed 14 and is for employee use only.  No change of parking.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2336	14041-10000-27674	13065 W TONOPAH ST	91331	6	195B161   572	2627035004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.23007	-118.41763	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD CENTRAL INVERTER PLAN. SYSTEM SIZE: 6.63 KW(26) KYOCERA KD 255(2) ABB # PVI 3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2337	16041-10001-23506	1331 N FIGUEROA PL	90744	15	033B201    19	7412009010	[Q]R3-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Harbor City		2943.02	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	33.78929	-118.28357	EXPEDITER PER APPLICANT REQUEST. ((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 40.25KWac. SOLAR SYSTEM FOR BLDG 6 & 7.(147)MODULES(7)INVERTERS(1)200A PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2338	14041-20000-13585	4039 S MICHAEL AVE	90066	11	108B153   509	4230016027	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	33.99309	-118.43988	Roof mounted PV system with Enphase microinverter, model M215-60-2LL.  System size 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2339	10041-10000-23431	11715 W GOSHEN AVE	90049	11	129B145   485	4265010005	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			11/23/2010 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.05008	-118.46232	NEW 9- UNITS APARTMENT BLDG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2340	13041-10000-29400	4941 E MONTE VISTA ST	90042	1	150A225    43	5467031008	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.1069	-118.20434	PV1.  Install 4 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US.  16 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2341	14041-10000-01507	14940 W VENTURA BLVD	91403	4	166-5A149 248	2276004024	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.15242	-118.4588	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK DONE TO BE INDOORS. 1255 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2342	10041-10000-17699	241 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			Corrections Issued	09/18/2010 12:00:00 AM	ADDRESS	34.04997	-118.22706	Solar voltaic system installed on the roof of the building.  Consists of  6 modules,  6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2343	14041-20001-11772	19130 W NASHVILLE ST	91326	12	210B121   713	2718016007	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.26865	-118.54986	addition of 3 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2344	15041-10000-35984	716 N ISABEL ST	90065	1	145-5A219 333	5453027005	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.0919	-118.22119	ROOF-MOUNTED 2.12KW PV SYSTEM WITH DC OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2345	10041-10001-20900	13455 W MAXELLA AVE Unit # 270	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	"Re-Plan check plans that was expired. First extension filed on 5/30/12. Install a new Fire Alarm System in an existing ""AMC Marina 6"" Theatre building.  <<<<Power and energy submitted under 10041-10000-20893>>>>>> Two bldg, title 24 on this app and other ckts on the other application, 10041-10001-20893"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2346	18041-10000-18432	5126 W WILSHIRE BLVD 1ST FL	90036	4	132B181    36	5507026022	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	34.06197	-118.34164	PLAN CHECK FOR TITLE 24 AND 1 EMERGENCY CKT;  LIGHTING SYSTEM HAS CHANGED FROM PREVIOUS TITLE 24 APPROVALTHESE ARE CHANGES TO APPROVED SET TO THE  MASTER APPLICATION# 17041-10000-03298THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2347	16041-10000-35551	4671-4681 E HUNTINGTON DR SOUTH	90032	14	142-5A231  87	5213013020	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.08562	-118.18389	Full Plan check Core and shell to a new 2 story retail building. Installing new service rated at 1200 amps 120/208 3phase 4wire. Indoor plus outdoor lighting included in title 24. Total sqft = 4668.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2348	18041-10000-40471	1175 N MADISON AVE	90029	13	144B197   374	5542028902	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.09299	-118.28961	INSTALLING OUTDOOR LANDSCAPE LIGHTING. T-24 ENERGY ONLY. BLDG PERMIT: 16020-10000-03521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2349	13041-10000-35387	3917 S WELLINGTON ROAD	90008	10	117B185   910	5045009004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/07/2014 12:00:00 AM	ADDRESS	34.0151	-118.33926	PV1, Install 2 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformerless inverter: Solaredge SE 3000A-US. (8) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2350	11041-10000-25977	1450 W HARRY BRIDGES BLVD ELECT/EQUI-P BLDG	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Closed	01/21/2015 12:00:00 AM	ADDRESS	33.76983	-118.27924	LEVEL V METHANE  MITIGATION SYSTEM FOR AT ELECT/EQUIP BUILDING FOR MAIN GATE CANOPY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2351	19041-10000-28783	555 S FLOWER ST FLR 27,28	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	PC FOR INTERIOR OFFICE TI OF AN EXISTING OFFICE SPACE IN HIGHRISE. AREA 1849SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2352	16041-20002-04069	9301 N TAMPA AVE #93	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			PC Approved	04/26/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	THIS IS PLAN CHECK ONLY.  CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  CHANGES INCLUDE FIXTURE TYPE AND REVISE ENERGY CALS.Plan check for Title 24 T.I. in existing space. Total area: 1,766 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2353	18041-20000-20266	5540 E MONTE VISTA ST	90042	1	151-5A227  66	5468023010	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.1109	-118.19594	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2354	16041-20000-07548	20545 W PLUMMER ST	91311	12	198B109    19	2748003085	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.24291	-118.58123	Plan check for energy only. TI to existing industrial building/warehouse. NEW OFFICES; RESTROOMS. New lighting (incl. emergency) and receptacles. 10,235sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2355	19041-10000-50728	13507 W VAN NUYS BLVD	91331	7	207B157   804	2619026900	[Q]C2-1VL-O-CDO-CUGU, [Q]P-1-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.26227	-118.42763	T-24, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES REPLACEMENT OF OUTDOOR FIXTURES TO LED. TOTAL S. FT. 31000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2356	18041-20000-05344	7001 S LA TIJERA BLVD	90045	11	102B173   219	4103008016	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			02/13/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	07/06/2020 12:00:00 AM	ADDRESS	33.97512	-118.37472	Plan check for power and energy. Project site is a 3-story apartment building over 1 level of basement parking garage. Work includes a 1,200-amp service and a total lighting area of 20,260 sq. ft.Note: Building application has been generated under 17010-20000-04647	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2357	19041-20000-42423	13400 N ANDALUSIA LANE	91342	7	225B157  1037	2510026002	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	PIN	34.31498146	-118.42209679	NEW ROOF MOUNTED 1.68 KW PV SYSTEM WITH 7 PV PANELS AND 7  MICROINVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2358	19041-10000-47554	6516 W SELMA AVE	90028	13	148-5A187 329	5547017044	(T)(Q)C2-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	05/26/2020 12:00:00 AM		Permit Finaled	06/17/2022 12:00:00 AM	ADDRESS	34.09965	-118.33163	PLAN CHECK FOR FIRE ALARM SYSTEM, (16)PANELS AND (640)DEVICES.***********4 LEVELS BELOW AND 10 LEVELS ABOVE GRADE, APPROXIMATELY (180,380)SqFt	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2359	16041-20000-05914	5343 N HILLTOP ROAD	90041	14	163-5A221 375	5671001036	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.14442	-118.21697	PV1.  Install 3.36 kW DC roof-mounted PV system.  Central inverter standard plan.  (12) SolarWorld 280W modules with (1) SolarEdge SE3000A-US transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2360	19041-20001-52450	1459 W 190TH ST	90248	15	060B193   376	7351001027	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	10/14/2020 12:00:00 AM	ADDRESS	33.85852	-118.30447	PV3.  Install 223.2 kW DC roof mounted PV system.  (558) modules with (5) 33.3 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2361	19041-10000-03628	1241 S SOTO ST	90023	14	121-5A221 114	5170017030	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.02743	-118.21975	**Permit fee is zero dollar due per AB-1414/SB-1222**PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 68.53KWdc / 53.3KWac.(178)MODULES-JINKO SOLAR JKM385M-72H-V(1)INVERTER-SOLAREDGE SE33.3KUW(1)INVERTER-SOLAREDGE SE20KUS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2362	18041-10000-40903	9401 N DE SOTO AVE	91311	12	198B109    69	2746008007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.24091	-118.58876	INSTALLING 999.9 KWAC ROOFTOP PV SYSTEM, ON EXISTING WAREHOUSE3152 MODULES, 10 (50.1-100KW) INVERTERS, 2 1600A PANELS, 90 BRANCH CIRCUITSPermit fee is  $ 0 in accordance with AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2363	17041-20001-38626	15060 W VENTURA BLVD #  130	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	ADDRESS	34.15287	-118.46147	01/12/2018 Changes to an approved set of plans. Changes have been made on the lighting floor plan and have been incorporated into the Title 24 compliance forms. *****Previous Work Description*****CHANGE OF USE FROM OFFICE TO COFFEE SHOPPLAN CHECK IS FOR TITLE 24B#17016-40000-23896	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2364	10041-10000-17358	520 S VIRGIL AVE	90020	4	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.06457	-118.28687	TI IN A HALLWAY OF AN EXISTING COMMERCIAL BUILDING. PLAN CHECK FOR T24 AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2365	18041-10001-21174	10250 W SANTA MONICA BLVD Kiost 9270	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"[This is plan check only, permit is covered under master# 18041-10000-21174]  Revision to approved plan, under Delta-3. Revise water heater load, updated panel schedule and demand load calculation. <<Initial Tenant Improvement to existing Food & Beverage Kios ""Leaff"" on ste# 9270PLAN CHECK IS FOR TITLE 24 AND POWER - NEW PANEL AND CIRCUITS>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2366	12041-10000-20643	8942 N WOODMAN AVE	91331	6	195B153   376	2640016005	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			Corrections Issued	11/14/2012 12:00:00 AM	ADDRESS	34.23244	-118.43804	25 kw roof mounted PV for a commercial Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2367	17041-10000-21747	11817 S MAJOR ST	90230	11	105B165   380	4220014053	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	33.98469	-118.40081	Title 24 plan check.  T.I. to existing warehouse.  New lighting included in this permit.  Lighting area = 2,410 sq. ft. (indoor) + 400 sq. ft. (outdoor)       Building permit #17016-30000-17543       Electrical permit for plugs and meters #16041-90000-36073       Electrical permit for AC units #17041-90000-05390	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2368	14041-20000-34384	11620 W WILSHIRE BLVD 440	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.05021	-118.45963	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVMENT FOR DENTAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2369	12041-10000-19665	9715 N FARRALONE AVE	91311	12	201B101   353	2727006019	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.24674	-118.61066	Plan check for new roof mounted 7.92KW photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2370	12041-10001-07374	3274 S CABRILLO BLVD PV-1	90066	11	114B149     8	4247003040	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2012 12:00:00 AM			PC Approved	08/30/2012 12:00:00 AM	ADDRESS	34.01264	-118.44717	INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL.5.98KW. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. ( permitt was issued under # 12041-10000-07374)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2371	11041-20001-25282	9338 N DEBRA AVE	91343	12	198B137   360	2676006020	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2012 12:00:00 AM			Corrections Issued	05/04/2012 12:00:00 AM	ADDRESS	34.2404	-118.49033	Original plans for a 6.27 KW PV SYSTEM were lost, and a quick over the counter review was performed to issue a stamped set of plans for inspection review.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2372	17041-10001-00786	6081 W CENTER DR suite 208	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Approved	09/18/2018 12:00:00 AM	ADDRESS	33.97811	-118.39245	Changes to approved set, noted as Delta-7. Add new Water Heater, revise load calculation, relocate time clock. Other information remain the same.<<<T-24, PC FOR ENERGY ONLY. TI FOR BEN & JERRY'S ICE CREAM. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1290 SQ. FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2373	17041-10000-05686	6021 W CARLTON WAY 1-24	90028	13	148-5A189 191	5545006027	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			02/22/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.10056	-118.32083	Plan check for power only for service upgrade from 400A to 800A  and additional units 6 units the existing Appartment building. B#16016-20000-22083	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2374	18041-30000-22884	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Info Complete	06/20/2018 12:00:00 AM	ADDRESS	34.0834	-118.37568	PLAN CHECK FOR T24 ONLY TO AN  (E) COMMERCIAL SPACE, TOTAL AREA UNDER THE SCOPE: 633 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2375	12041-10000-07426	1801 E 50TH ST 1st floor	90058	9	111A213   156	5106027004	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM			PC Approved	04/02/2012 12:00:00 AM	ADDRESS	33.99812	-118.24177	CHANGE OF USE FROM WAREHOUSE TO GARMENT CUTTING AT WEST WING OF GROUND FLOOR  (6,584 SQ. FT) AND LIGHTING FIXTURE RELOCATION.  Maximum occupancy load of 30 people and 110A of load, per the applicant.  => Plan check only for Energy, with Emergency lights.  Full plan check may be required, subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2376	18041-10000-12868	246 N CATALINA ST	90004	13	138B197   408	5518025001	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/10/2020 12:00:00 AM	ADDRESS	34.07588	-118.29529	PLAN CHECK FOR TITLE 24 ONLY FOR NEW 6 UNIT APPARTMENT - CONNECTED LOAD <400A. MSA = 400A. TOTAL AFFECTED AREA = 3500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2377	18041-20001-38452	1000 S HOPE ST	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.04346	-118.2617	expeditepv2install roof mounted pv system sized 40Kw AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2378	15041-10000-29250	960 W 62ND PL	90044	9	105B197  1072	6004015019	C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Apartment			09/03/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	33.98261	-118.29095	ADDITION TO AN EXISTING FIR ALARM SYSTEM, 18 FA DEVICES AND RPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2379	19041-20000-31308	1100 W 256TH ST	90710	15	036B197   954	7413011014	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.79177	-118.29609	Plan check for PV roof mounted system, PV system size: 6.6KW DC, 5.985KW AC with 20 PV Modules and 10 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2380	18041-10000-19339	900 W WILSHIRE BLVD 12TH FLOOR	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.05001	-118.25963	T-24, PC FOR ENERGY ONLY FOR AN OFFICE SPACE ON THE 12TH FLOOR. TOTAL AFFECTED AREA IS 2204 SQ. FT. B#18016-10000-14966	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2381	10041-10000-04574	1507 S GRANDE VISTA AVE	90023	14	118-5A223 168	5169001002	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	05/27/2011 12:00:00 AM	ADDRESS	34.01771	-118.21007	UPGRADING SERVICE TO 600AMPS FOR A COMMERCIAL BUILDINGNO CHANGES IN THE LOADS AND THE LIGHTING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2382	13041-10001-23719	22935 W MARIANO ST	91367	3	171B097    78	2042008052	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.16843	-118.62683	][][] CHANGES MADE TO AN APPROVED SET OF PLANS; MODULES CHANGED FROM TRINA SOLAR -245W TO SUNIVA 265W. INVERTERS UPSIZED FROM V7.5 TO V 10.0 ][][][PV1 9.8KWdc 240V XFMR (neg grounded) INV. ?STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 40) MOD: Trina {TSM-245PC05.18}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2383	19041-20000-07886	8134 N MASON AVE	91306	3	189B109    66	2107008011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.21801	-118.57956	Plan check for PV install in to existing PV system, addition PV system size: 7.15KW DC, 6.0KW AC with 22 PV Modules and new load center. Total new and existing PV System size: 14.3KW DC, 12.0KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2384	14041-20001-10128	10501 N MONOGRAM AVE	91344	12	207B137   788	2679002035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.26133	-118.49261	EXPEDITE PER APPLICANT REQUEST(((PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 4.25kW(1) SolarEdge #SE3800A-US-ZB-U transformerless inverter(17) Canadian Solar #CS6P-250PXpv modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2385	13041-10000-09417	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.03396	-118.24117	NOVEC 1230 SUPPRESSION SYSTEM. NEW FIRE ALARM SYSTEM. 8 DEVICES. 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2386	16041-20000-27888	3221 S LA CIENEGA BLVD	90016	10	120B173    38	4205035007	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Issued	08/09/2016 12:00:00 AM	ADDRESS	34.02888	-118.37221	"Manufacturing building TI.  Plan check for energy.  3342 sq ftBuilding permit filed under 16016-20000-14904.  Order for property: ""COMPLY WITH DEPARTMENT ORDER effective date05/16/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2387	19041-20000-37064	11211 N SEPULVEDA BLVD lot #18	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 2.83 KW DC ROOF MOUNTED PV SYSTEM WITH (9) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2388	19041-20002-06868	8700 S PERSHING DR PV3	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Revisions to approved set of plans and change of scope of work.  Approval for clouded changes delta-1 only.  Work description change: PV2.  Install 21.90 kW DC / 20.01 kW AC roof mounted grid tied PV system.  (60) modules with (1) 20 kW rated inverter.  Interconnecting with MSA-3.  (((PV2.  Install 22.27 kW DC / 20.34 kW AC roof mounted grid tied PV system.  (61) modules with (1) 20 kW rated string inverter.  Interconnecting with MSA-3.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2389	17041-10000-13365	612 S CROCKER ST	90021	14	126A213    50	5147027038	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.04128	-118.24457	T24 ONLY, REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 4000 SQ FT, INDOOR AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2390	16041-20001-45251	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	10.18.2017 - Plan check for modifications to approved set. Add 16 fixture F7s in elevator lobby. Update floor plan and T24 documents to reflect changes. Changes clouded.======Plan check for energy only. TI to North Lobby of high rise building. New lighting (incl. emergency). 6,080 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2391	16041-30000-38098	8005 S FIGUEROA ST	90003	8	099B201   809	6032025027	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	33.96646	-118.28296	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2392	15041-10000-05038	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.0484	-118.26248	Power plan check for upgrade to pressure maintenance pump. No other new loads have been added. (changes to approved set - new engineer on record) Original approved set: 13041-10002-27007	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2393	16041-30003-44582	1660 W BEVERLY BLVD	90026	13	135A207   240	5153012003	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM			PC Info Complete	03/06/2018 12:00:00 AM	ADDRESS	34.06404	-118.26497	"03-06-2018 Changes to an approved set of plan. Changes include revised single line diagram, additional disconnect, load to panel ""SR1"", ""P1"" and ""P2"", revised location of panel boards. Changes has been clouded as delta 4."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2394	12041-10000-25826	1115 S LOS ANGELES ST	90015	9	126A209   246	5139016013	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Public Safety Only			10/29/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.03808	-118.25761	New fire sprinkler monitoring system for a commercial Bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2395	17041-10000-38067	1221 W VALROSE CT	90041	14	162A229   210	5690007047	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.13774	-118.19369	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.68KWac.(24)MODULES-SUNPOWER X22-360-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2396	15041-20000-37767	3535 S LA CIENEGA BLVD	90016	10	120B173   388	4205028002	[Q]C4-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM			PC Approved	12/14/2015 12:00:00 AM	ADDRESS	34.02292	-118.37248	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (TARGET STORE). SCOPE INCLUDES NEW TRACK LIGHTING. TOTAL AFFECTED AREA IS 1325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2397	18041-10000-06535	1030 N SWARTHMORE AVE UNIT 2-113	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	FULL PC FOR POWER AND ENERGY. TENANT IMPROVEMENT TO EXISTING CORE & SHELL SPACE FOR RESTAURANT. SCOPE INCLUDES NEW 400A DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 3470 SQ. FT. B#18016-10000-03231	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2398	16041-20000-05556	8314 W 3RD ST	90048	5	138B173   892	5511031036	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM			PC Info Complete	02/24/2016 12:00:00 AM	ADDRESS	34.07259	-118.37057	Plan check Title 24 only for existing restaurant. Total area: 345 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2399	19041-10000-47948	740 S BROADWAY	90014	14	127-5A209 107	5144015023	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Issued	12/20/2019 12:00:00 AM	ADDRESS	34.04414	-118.25412	FULL PLAN CHECK FOR A FIRE ALARM SYSTEM. PLAN CHECK INCLUDES 1 FIRE ALARM PANEL, 4 POWER SUPPLIES, 1 COMMUNICATOR, AND 324 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2400	18041-10000-08776	304 S BROADWAY SUITE #300	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			PC Approved	03/09/2018 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR ENERGY ONLY FOR AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3265 SQ. FT. B#17016-10000-38508	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2401	17041-10000-29091	8338 S LINCOLN BLVD	90045	11	096B157   258	4113016019	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	33.96183	-118.42074	PC for T24 only for change of use TI from retail to restuarant. Installing new lights and kitchen equipment. Total area of 1058 sqft. Building # 17016-10000-17897.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2402	19041-10000-05333	8021 W MULHOLLAND DR	90046	2	156B173   141	2380030901	[Q]PF-1XL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.12614	-118.37428	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2403	13041-10000-25283	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLAN CHECK FOR TITLE 24 ONLY. CHANGE OF USE FROM TAKE OUT RESTAURANT TO RETAIL SPACE 1,986 SF. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. TRANSFORMER IS EXISTING TO REMAIN LOCATED IN CEILING SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2404	17041-10000-18507	2049 S CENTURY PARK EAST 34TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 FOR TI (RENOVATION TO PUBLIC RESTROOMS ON 14TH FLOOR-HIGH RISE) TOTAL AFFECTED AREA 410 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2405	15041-20000-20572	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	PIN	33.92817449	-118.43220714	Plan check for Emergency Standby System 4.1kV . Replace disconnect switches with breakers, add battery , add standby generator, modify controls. (4) 1200A Sections,  (1)1000kW Generator @ 4.1kV	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2406	17041-10001-20034	7034 N TAMPA AVE	91335	3	183B117   395	2129007007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.19844	-118.55331	PC for supplemental to approved changes. Removing subpanel and relocating gateway from partial backup mode to full back up mode.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2407	15041-10000-03032	13368 W BEACH AVE 1-21	90292	11	108B153   847	4230007004	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			02/02/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	33.99147	-118.44362	Installation of new fire alarm system in new 4 story 21 unit apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2408	18041-10000-29169	1168 S LA BREA AVE BLDG G1	90019	10	132B181  1202	5084021015	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	07/25/2020 12:00:00 AM	ADDRESS	34.05413	-118.34323	TI to (E) art gallery building.  Plan check for energy - 8076 sf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2409	12041-20003-10803	4108 S DEL REY AVE	90292	11	108B153  1216	4230005040	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			04/24/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.98836	-118.4448	Changes from previously approved plans.  Changes include reducing distribution section circuit breaker rating, replace diesel generator with 30KVA inverter,and adding subpanel.  No changes in lighting.  Plan check for power only.  All changes indicate by DELTA 10*****Previous Description****New 77 unit apartment. Plan check for power and energy. 4 story apartment. Equipped with a generator. 106130 conditioned sqft. Fire alarm variance on file.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2410	18041-20000-41886	13254 W ARMINTA ST	91605	2	189B157  1036	2303004021	RE9-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.21324	-118.42245	Plan check for PV roof mounted system, system size: 14.4kW DC, 12.24KW AC with 40 AC Modules connected to 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2411	17041-20000-12202	16188 W ROYAL OAK ROAD	91436	5	162B141   272	2286013015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.13958	-118.48337	permit fee $0.00 by state senate bill no.122PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.78 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2412	15041-20001-01180	6863 W CAMROSE DR	90068	4	151-5A185 328	5549025006	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	34.10908	-118.33928	[[[6/4/15 changes to approved set to change number of modules on roof from 18 to 14]]]]]PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 18 MODULES IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2413	13041-10000-03981	2626 E 25TH ST	90058	14	117A219   147	5168023009	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.0152	-118.22477	REPLACEMENT OF 480V DISTRIBUTION SYSTEM. RATED AT 4000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2414	12041-20000-10939	21358 W NORDHOFF ST bldg. #5-#105/106	91311	3	195B105   365	2779017***	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM			PC Approved	05/11/2012 12:00:00 AM	ADDRESS	34.23523	-118.59705	Tenant improvement for existing office space. Plan check for energy. Single story commercial. 492 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2415	14041-20000-17747	281 S LORING AVE	90024	5	138B153   104	4359002021	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.07669	-118.43571	New 2-story SFD with basement and 2-car attached garage.  New 600 service, panel, and branch circuits.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2416	15041-10000-33337	915 W WILSHIRE BLVD	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Issued	10/07/2015 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI TO EXISTING HIGHRISE BUILDING ON 21ST FLOOR. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2417	13041-10001-25887	617 W 7TH ST BASEMENT	90017	9	129A209   113	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.04779	-118.2571	(((3/27/2014- CHANGES MADE TO APPROVED SET. RELOCATION OF SOME LOADS AND INSTALL OF NEW HVAC UNITS AND REFRIGERATION EQUIPMENT. NO CHANGES MADE TO SINGLE LINE DIAGRAM. WORK DESCRIPTION FROM ORIGINAL HAS BEEN COPIED TO 'APP COMMENTS'))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2418	19041-10000-17658	5555 W MELROSE AVE Bldg #213	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Issued	07/01/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	NEW FIRE ALARM SYSTEM WITH 288 DEVICES IN BUILDING #213.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2419	10041-10000-12784	500 W WORLD WAY MCP-02	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-02. This applicaation separates MCP-02 from the entire project on PCIS 09041-10001-24166( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2420	15041-20000-15922	5700 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	05/26/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	Title 24 plan check only.  Total area = 4,759 sq. ft.T.I. to existing commercial highrise office space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2421	15041-10000-21319	1055 W WILSHIRE BLVD Ste #1100	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.05232	-118.2629	Energy plan check for an office T.I located in 11th floor, suite #1100, of a high rise building. Total area is 22365-SQ feet. Scope includes new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2422	19041-10000-35960	4780 N CERRILLOS DR	91364	3	168B101   736	2170003016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.15503	-118.61246	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 25 AC MODULES (SUNPOWER X22-360). SCOPE INCLUDES NEW 125A LOAD CENTER. SYSTEM SIZE IS 9KVA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2423	17041-10001-05914	1830 N BRONSON AVE 1-81	90028	13	150A191   264	5586028026	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.10433	-118.31784	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REPLACING LIGHTING FIXTURES, REVISING TITLE 24 CALCULATIONS, AND REVISING FLOOR PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2424	17041-20000-11721	830 N FAIRFAX AVE	90046	5	141B177   150	5527002033	C2-1VL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.08635	-118.36121	First time tenant - coffee shop.  Plan check for power and energy.  Building permit filed under 17016-10000-02778	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2425	14041-20000-04281	14651 W OXNARD ST	91411	6	177A149    92	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.17954	-118.4527	T.I. to existing office building.  Existing 600 service.  Install new equipment rate 600A.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2426	15041-20000-00783	8901 N RANCHITO AVE	91402	6	195B153   515	2639037028	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.23157	-118.43957	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNETED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2427	18041-10000-04610	449 N LA BREA AVE	90036	5	141B181  1302	5525028003	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Issued	03/21/2018 12:00:00 AM	ADDRESS	34.07968	-118.34423	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR AND EXTERIOR WORK . TOTAL AFFECTED AREA 11936 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2428	12041-10000-06501	13600 W MARINA POINTE DR	90292	11	105B153   610	4229018052	C4(OX)-2D, [Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	33.98473	-118.44411	19 story commercial bldg, panel replacement, panel on first floor. and 15 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2429	17041-10000-32848	642 E 62ND ST	90001	9	105B205   810	6007010002	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Issued	10/13/2017 12:00:00 AM	ADDRESS	33.9831	-118.2631	PC FOR 1000A SERVICE UPGRADE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2430	18041-20000-36129	10427 W WOODBRIDGE ST	91602	4	165B177   572	2424017017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.14876	-118.35793	Plan check for PV roof mounted system, system size: 10.065 KW AC CEC with 1 inverter(10kW) and 33 PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2431	15041-10000-11650	110 E 22ND ST BLDG 9A	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	33.72668	-118.27682	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  SERVICE UPGRADE TO 5000 AMPS TO POWER TENANT SPACE 9A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2432	14041-20001-13962	20271 W VIA MEDICI	91326	12	219B113   149	2701043021	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.29451	-118.57542	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2433	18041-10000-31232	8225 N COLDWATER CANYON AVE	91605	2	192B161   221	2304002028	R1-1, RA-1, RA-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.22076	-118.41457	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2434	19041-20000-37562	3197-3199 N GLENDALE BLVD	90039	13	154-5A207 196	5435026023	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.11798	-118.26125	Plan check for Title 24 Energy only add new lights and equipments total area: 1178 sq ft. B#19016-20000-29918	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2435	19041-20000-41039	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2436	15041-10000-24705	3813 W EVANS ST	90027	4	150B201   669	5433024012	R2-1XL	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM			Reviewed by Supervisor	08/11/2015 12:00:00 AM	ADDRESS	34.10706	-118.27431	PV1, ROOF MOUNTED SYSTEM, 40 MODULES, 1- 3KW AND 1- 5KW INVERTER. TOTAL SIZE 10.6KW. (40) KYOCERA #KU2656ZPA(1) ABB- PV1-3.0-OUTD-S-US-Z-A(1) ABB- PV1-5.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2437	12041-20000-27290	16760 W SCHOENBORN ST	91343	12	192B137   233	2689012005	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/14/2012 12:00:00 AM	ADDRESS	34.2231	-118.49828	Relocate one panel, one new panel, new circuits and lighting for an existing aviation manufacturing company.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy,  NO Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2438	12041-20000-03313	6420 W WILSHIRE BLVD 20th fl.	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.06365	-118.36922	office t.i.Energy, emergencyFire/ Life safety is 12041-10000-03313	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2439	15041-20000-27413	601 S FIGUEROA ST Suite 1900	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 12,300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2440	13041-20000-19049	555 S FLOWER ST FLR D	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Info Complete	07/18/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	NEW CIRCUITS FOR PUMPS. NON HAZARDOUS. PC FOR POWER. FOR FIRE PUMP AND EM GENERATOR. REPLACE EXISTING. WORK DONE IN FLOOR D	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2441	13041-20000-16013	2220 S AVENUE OF THE STARS	90067	5	129B161    53	4329003***	R4-1L-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Apartment			06/18/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.05241	-118.40939	"change out of existing 800A rated equipent. equipment changeout to be like for like. existing 800 for new 800. PC for interupting rating only per applicant. this continues scope of work under application # 13041-10000-11935. this panel is named ""PD2B"" ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2442	13041-20000-17228	9223 N DEERING AVE	91311	12	198B105   114	2746010048	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.23859	-118.59622	New circuits and equipment for an existing low-rise commercial space.  Networking/Server equipment.  Plan check for Power, no change to lighting.  Project valuation is less than $200,000 per applicant - No green fee charged.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2443	13041-20001-01249	1609 N MAGNETIC TER	90069	5	147B169   322	5561013022	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			PC Approved	07/01/2014 12:00:00 AM	ADDRESS	34.10018	-118.39177	Modification to approved set.  Change of module and inverter models.  (((Photovoltaic systm on roof of single family dwelling with subpanel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2444	16041-10000-42133	4650 W KINGSWELL AVE	90027	4	147B197   146	5590026001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	04/08/2021 12:00:00 AM	ADDRESS	34.10252	-118.29143	PC for T-24 for TI for new Bar in single story building. Installing new lights and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2445	16041-20001-06275	20345 W ARMINTA ST	91306	3	189B113   852	2107010024	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	PIN	34.21338085	-118.57695569	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a SFD. Existing solar array on roof, connecting new array and existing array to a 125A load center. Interconnecting with a 200A MSP.System size: 3kW (new) + 3.8kW (existing). Ungrounded system.(14) new 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2446	15041-20000-35687	523 W 6TH ST 28TH FLR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM			PC Approved	10/26/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI;  NEW SUSPENDED CEILING AND LIGHTING AT 28th FLOOR CORRIDOR AND ELEVATOR LOBBY.  1983 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2447	13041-10000-22331	7244 W ROWLEY PL	91042	7	207B197   253	2553002012	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.26639	-118.29016	PV1 3.096KWAC 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 12) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2448	14041-10000-35439	20630 W SUPERIOR ST	91311	12	201B109   237	2748040017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.24625	-118.58311	T24 ONLY. REMOVING HID LIGHT FIXTURE AND REPLACE WITH LED FIXTURES. TOTAL AREA 5395 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2449	10041-20000-24540	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Public Safety Only			12/09/2010 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.87528	-118.29083	Plan check new fire alarm system for 5 story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2450	16041-20000-44396	10250 W CONSTELLATION BLVD Ste 800	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI to (E) commercial office space on 8th floor of highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2451	16041-10001-02499	6333 W 3RD ST STALL 110	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.07157	-118.36014	Supplemental PC only for 5 floor heaters (on 1st floor). Permit under 16041-10000-02499, and 16041-10000-00593. ***T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTUARANT/BAR.  SCOPE INCLUDES ADDING NEW LIGHTING TO AN OUTDOOR STEEL COVERED DINING AREA ON GROUND FLOOR.TOTAL AFFECTED AREA IS 760 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2452	19041-20000-19866	8914 N ENFIELD AVE	91325	12	195B129   222	2768003011	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.23252	-118.52429	Plan check for PV roof mounted system, system size: 12.96KW DC, 10.0KW AC with 36 PV Modules and 1 inverter(10.0kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2453	19041-20000-20205	17415 W MAYFLOWER DR	91344	12	213B129   129	2607010006	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.2818	-118.51362	Plan check for PV roof mounted system, system size: 11.16KW DC, 10.19 AC with 36 PV Modules and 1 inverter(10.0KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2454	19041-10000-01233	11687 W NATIONAL BLVD	90064	11	120B153   978	4258009010	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.023	-118.4384	FULL PLAN CHECK FOR A T.I  FOR AN EXISTING MEDICAL OFFICE. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 1,895 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2455	18041-10000-46081	11911 W BRANFORD ST SHOP-BUILD.	91352	7	204B165    72	2528007014	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Issued	12/04/2018 12:00:00 AM	ADDRESS	34.2567	-118.39186	Install new Fire sprinkling monitoring system in the FedEx Shop Building, (1) FACP, (7) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2456	17041-30000-39780	131-139 S LA BREA AVE	90036	5	138B181  1040	5513019040	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.07261	-118.34429	Plan check for power and energy Service upgrade to 800A only, core and shell in mix use Building, there is no tenant in commercial area at this time,  Residential meters existing to remain. Total area: 4,950 sq ft.  (indoor and outdoor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2457	15041-20000-42483	16633 W VENTURA BLVD #940	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	PC for Energy only. Total area 2440sq.ft. All electrical equipment are existing.((INTERIOR REMODEL TO THE (E) OFFICE SPACE. INSTALL NEW NON STRUCTURAL PARTITIONS, CEILINGS AND DOORS.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2458	16041-20001-43699	9240 N JORDAN AVE	91311	12	198B105   122	2746012038	[T][Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.23844	-118.60377	(2/21/2017) changes to an approved set of plans.  changes noted delta 3.  changes include different light fixtures and changes energy forms.  this is plan check only.(((Plan check for energy only. TI to existing manufacturing building - electrical equipment wholesale. New lighting (incl. emergency) and receptacles. T24 area: indoor- 34,469sqft; outdoor- 50,138sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2459	18041-10000-13848	1914 S RAYMOND AVE	90007	1	126B197   749	5075033009	[Q]CM-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Info Complete	07/13/2018 12:00:00 AM	ADDRESS	34.03945	-118.29727	PLAN CHECK FOR POWER AND ENERGY FOR COMMERCIAL BUILDING WITH RETAIL SPACES - BUILDING HAS EXISTING DISTRIBUTION EQUIPMENT WITH 6 SERVICES AND ASSOCIATED EQUIPMENT - PLAN CHECK INCLUDES ADDITION OF ALL NEW LOAD WITH ADDITION OF NEW PANELS. TOTAL AFFECTED AREA = 33153 SQW. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2460	17041-20000-12462	6600 N TOPANGA CANYON BLVD 99A	91303	3	180B101   822	2139004044	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Issued	10/02/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	ti to an existing commercial space.  adding new lighting new controls to new panel.  newly connected load less than 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2461	10041-20001-22136	316 S LORRAINE BLVD	90020	4	135B189   237	5504005006	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2011 12:00:00 AM			PC Approved	03/10/2011 12:00:00 AM	ADDRESS	34.06834	-118.31979	PLAN CHECK PER INSPECTOR. INSTALL ROOF MOUNTED 7.525 DC PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING.Note: permit issued under 10041-20000-22136	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2462	13041-10000-11376	1059 S BROXTON AVE	90024	5	132B149    60	4363024006	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.06142	-118.44645	PC POWER/ENERGY. TI RESTauRaNT to FAST FOOD IN EXISTING BUILDING. new service, swbd, and 2 panels. emergency lighting supplied by inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2463	19041-20000-25513	7802 W TORREYSON DR	90046	4	159B173   654	5570014020	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.12858	-118.36918	addition of (2) tesla ESS to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2464	13041-20001-16989	8375-8449 N LAUREL CANYON BLVD	91352	6	192B165   307	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.22391	-118.39926	(((CHANGES MADE TO APPROVED SET OF PLANS. RELOCATING PANEL FOR TENANT AND IDENTIFIYING EXISTING FEEDERS)))UPGRADING (2) 2000A MAIN SWITCH BOARDS AND ALL THE FEEDERS FOR CANYON PLAZA SHOPPING CENTER. NO LOADS ARE BEING ADDED TO THE PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2465	14041-20000-12540	10700 W SANTA MONICA BLVD 2nd floor	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	PLAN CHECK FOR ENERGY ONLY3-story commercial building. Extension of lighting on second floor hallway.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2466	13041-10000-12486	7203 N RUBIO AVE	91406	6	183B137    51	2226016015	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			05/14/2013 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.20163	-118.49594	PC FOR POWER/ENERGY. NEW 29 UNIT APT.4STORY.1ST FLOOR grade level  AND 3 STORies above. 8 typical units. not methane . fully sprinklered. engr = robert tomasianCONSTRUCT NEW 29 UNIT APT AND SALE OFFICE AS AN ACCESSORY USE TO THE BUILDINGNO PROGRESS - PC APPROVE IS FOR GRADING PERMIT R&R ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2467	11041-10000-02505	12144 W MAGNOLIA BLVD	91607	5	171B165   567	2356001020	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.16471	-118.3981	Upgrade service at building from 200 to 800 amperes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2468	15041-20001-02260	5700 W SANTA MONICA BLVD	90038	13	144B189   691	5536017034	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.0906	-118.31379	Plan check for power only.  Title-24 has already been approved on master application.  Service upgrade to 1200 A with new distribution equipment.*****Previous work description*****Plan check for energy only. First time tenant (7/11). New lighting including emergency. Total sqft. 2,260.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2469	12041-20000-30797	14402 W HAMLIN ST	91401	6	180B149   633	2237023020	(T)(Q)RAS4-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			12/21/2012 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.18841	-118.44675	Plan check for power and energy (energy is per applicant request). Fire alarm variance has been filed. 25 unit three story apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2470	13041-20000-23787	7021 N HAYVENHURST AVE	91406	6	183B137   212	2225003023	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.19818	-118.49259	T24 FOR EXISTING OFFICE SPACE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. TOTAL SQRFT 3465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2471	15041-10000-14888	1100 S HILL ST	90015	14	126A209   128	5139019034	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/15/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.03989	-118.25984	(N) 7-story mixed use 185 unit apartment building with 2 levels of basement parking garage.  (2) 3000A 120/208 services.Fire alarm variance filed 05/15/2015Building permit was submitted prior to July 1, 2014 - 2008 Energy Code	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2472	18041-10000-48054	3022 S 8TH AVE	90018	10	120B189   444	5051037030	R1-1XL-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.02687	-118.32583	PV1. INSTALLATION OF 5.76 KWdc and 5.13 KWac ROOFTOP PHOTOVOLTAIC SYSTEM INCLUDING (16) SUNPOWER 360W AC MODULES AND A 200A MAIN SERVICE PANEL UPGRADE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2473	10041-10000-06712	2293 S MINER ST	90731	15	018B201   130	7440026903		Harbor				2971.10	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	33.72266	-118.2779	Install 2 NEW 7-1/2 hp Fire Pumps in the North West portion of the Port of LA adjacent to the MS2 & MS2A. Only pages E-22 and FP-1 were reviewed and approved by plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2474	15041-20000-29835	12643 W SHERMAN WAY UNIT B	91605	2	183B161    12	2324003046	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.20136	-118.40837	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CRICKET WIRELESS. UNIT B  965 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2475	13041-10001-21438	1245 W WILSHIRE BLVD 2ND FLOOR	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM			PC Info Complete	02/17/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	12-15-15CHANGES TO AN APPROVED SET OF PLANS,  A SURGICAL CENTER/OSHPD III FACILITY.  NOTE CHANGES ON DELTA 8. CHANGES INCLUDE REVISED LOAD. (((PLAN CHECK POWER AND ENERGY.  T.I. TO PROVIDE AN AMBULATORY SURGICAL CENTER/OSHPD III WHICH WILL CONTAIN 8 OPERATING ROOMS, 28 PRE/POST OPERATING BEDS AND SUPPORT AREAS. HIGH RISE MEDICAL BUILDING.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2476	12041-10000-09552	8767 N PARTHENIA PL	91343	7	195B145   445	2654012026	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Expired	10/22/2012 12:00:00 AM	ADDRESS	34.22923	-118.4666	New fire alarm system for an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2477	14041-20000-08688	9144 N DEERING AVE	91311	12	198B105   160	2746010031	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.237	-118.59594	T.I. of existing offices.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under 14041-90000-04747	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2478	16041-10003-43717	1750 N GLENDALE BLVD	90026	13	144A209   317	5423005004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.08713	-118.25942	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE INCLUDES REVISION TO SWITCHBOARD ELEVATION, NO CHANGE TO LOADS, ALL CHANGES ARE CLOUDED UNDER DELTA 10. Orginal Scope__________________________________________________________________________________This is plan check only, permit is covered under master #16041-10000-43717. Changes to approved set, noted as Delta-6. Scope includes: reducing the breaker & fuse size of distribution boards MG1 & MG2. Updated load calcalulation is included.<<PC for new five story apartment with 70 units with two levels of subtarrenean basement.  PC for new 3000 A, 120/208 service.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2479	15041-20000-20244	5 N LATIMER ROAD	90402	11	126B129   770	4409029004	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.03873	-118.5137	Plan check for PV roof mounted system. System size: 12kW with 40 microinverters and 2 inverter(5.0kW and 7.7kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2480	13041-10000-25789	2515 S CENTRAL AVE UNIT A	90011	9	118-5A209 348	5131026029	C2-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			Corrections Issued	09/20/2013 12:00:00 AM	ADDRESS	34.0193	-118.25496	TI for Chase Bank.  Newly connected load less than 400 A, Title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2481	19041-10000-24234	13730 W RIVERSIDE DR	91423	4	168B157   318	2269025002	C2-1L, C2-1L-RIO, P-1L, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	34.15674	-118.43277	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT OF (E) RETAIL STORE. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROL. TOTAL AFFECTED AREA IS 43,746 SQ.FT TOTAL NEW CONNECTED LOAD IS LESS THAN 400AB#19016-10000-19112	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2482	19041-10000-46002	11401 N PORTER VALLEY DR	91326	12	213B117   356	2822037015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Closed	03/23/2021 12:00:00 AM	ADDRESS	34.27819	-118.55187	TITLE 24 PLAN CHECK. ADDING NEW LIGHTING FIXTURES. TOTAL AFFECTIVE AREA: 1139 SQ/FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2483	18041-10000-00489	845 E G ST	90744	15	030B209   279	7424011059	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.7792	-118.25211	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 14450 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2484	19041-20000-10866	12244 W OXNARD ST PV2	91606	2	177B165   746	2340003017	RD3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.17921	-118.4005	Plan check for PV roof mounted system, system size: 1.83KW with 6 PV modules and 6 microinverters. Unit number 2.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2485	12041-10000-07251	2810 E WHITTIER BLVD	90023	14	123A223   177	5189004019	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.0315	-118.20975	New 2kw groundmount photovoltaic system with trenching for an existing commercial building with 1000A service. (PV2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2486	15041-20002-21994	11650 W PICO BLVD	90064	11	123B153   717	4260033033	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			01/13/2017 12:00:00 AM			PC Approved	01/13/2017 12:00:00 AM	ADDRESS	34.03185	-118.4448	[ changes to approved set. relocating msa2 from electrical room to parking area. delta d chages. changes are clouded]]]Change to approved set by adding (16) EV-chargers  and a panel to the MSB switchboard. All changes are under delta-B only.PC FOR POWER AND ENERFY FOR NEW MIX USE OF 71 UNITS APARTMENT, (5) RETAIL STORES,  AND  (2) SUBTERRANEAN PARKING BUILDING. SCOPE INCLUDE 3000-AMP SERVICE 3-PHASE 120/208V. AND  (15) TYPICAL UNITS FOR APARTMENT UNITS. TOTAL AREA FOR T-24 IS 59,885-SQ FEET. ALL MIS.-LOAD IN RETAIL PANEL ARE FOR DESIGN ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2487	14041-20000-04178	11388 W VENTURA BLVD	91604	2	162B173   608	2378021022	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.13976	-118.3787	T24, PART 6 ENERGY FOR 2-STORY COMMERCIAL BUILDING. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING WORK IS APPROX. 1434 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2488	15041-20000-01590	990 N HILL ST	90012	1	136-5A215 169	5414007028	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM			PC Info Complete	04/22/2015 12:00:00 AM	ADDRESS	34.06691	-118.23727	Plan check for power and energy. Fire damage repair to 2-story office/retail building + a subterranean garage level. 800 service replacement, core and shell complete rewire. Methane zone. 18,325 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2489	15041-20001-20815	6320 N TOPANGA CANYON BLVD G-1625	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	"10-19-2015 Change to approved set of plans. Changes include revised Lighting Fixture Schedule, new transformer, new panel ""D"", new load on panel ""D"", 2 new light fixtures on Mezzanine, recalculate Title 24 calculation and changes apply to delta 6 only. [[[[[[[[PLANECHECK FOR POWER AND ENERGY. FIRST TIME TENANT. EATSA.  BUILDING G UNIT 1625.]]]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2490	15041-10000-03201	21040 W CALIFA ST	91367	3	174B105     8	2149002021	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.17715	-118.59163	CHANGING OUT EXISTING SWBD AND USING IT AS DISTRIBUTION BOARD; SERVICE REMAINS THE SAME; ADDING TRANSFORMER TO SUPPLY FUTURE DISTRIBUTION BOARD AND LOADS UNDER SEPARATE APPLICATION. NO NEW LOADS AT THIS TIME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2491	16041-10000-25984	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	PLAN CHECK FOR TITLE 24 ONLY.TENANT IMPROVEMENT TO EXISTING OFFICE AREA.  NEW LIGHTING AND RECEPTACLES.  ALL PANELS TO REMAIN EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2492	16041-20001-12634	433 S HOBART BLVD COMMON-AREA	90020	10	135B193   545	5503012022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Apartment			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.06614	-118.30552	Plan check for Title 24 only in existing corridor and stairwells of appartment building. Total area: 3,348 sq ft. {{{{{{INSTALL (39) LIGHTS MAXIMUM. IF EXCEEDS THE MAXIMUM MUST COMPLY WITH TITLE 24 PER PLAN CHECK.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2493	19041-20000-46063	11553 W DONA DOROTEA DR	91604	2	156B169    76	2381023005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.12745	-118.38623	Plan check for PV roof mounted system, PV system size: 5.11KW DC, 4.72KW AC CEC with 14 PV Modules and 1 inverter(3.8KW) and 1 energy storage LG Chem 9.8KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2494	11041-10001-07773	6253 W HOLLYWOOD BLVD #201	90028	13	148-5A189 343	5546030035	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.10179	-118.32624	Change of use and first time tenant.  New use is office space.  Per inspector, full plan check is needed.  Title 24 was already approved under PCIS # 11041-10000-07773  <<<<<Ti for an office Bldg. Epc for T24 & Energy.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2495	18041-20000-06972	105 S FAIRFAX AVE	90036	5	138B177   597	5511025078	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Apartment			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.07398	-118.36162	New fire alarm system for four-story apartment building.  (82) devices with new FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2496	13041-10000-27390	920 W DOWNEY WAY basement	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.02063	-118.28879	PC FOR ENERGY. TI TO (E)  MECH ROOM IN BASEMENT. less than 400A total connected load per applicant.  vacuum pump and air compressor replacement. Basement of Beigler Hall of Engineering (BHE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2497	11041-10000-22816	12800 W CULVER BLVD	90066	11	105B157   410	4221031009	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Issued	11/14/2011 12:00:00 AM	ADDRESS	33.98489	-118.42552	Fire alarm replacement system in an existing Dish Network building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2498	19041-10000-14354	932 W 78TH ST	90044	8	099B197   434	6020013009	RD1.5-1	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Expired	11/18/2023 12:00:00 AM	ADDRESS	33.96868	-118.29042	(ePlan) PLAN CHECK FOR 2.61kW DC, 3KVA AC PV SYSTEM CONSISTING OF 9 MODUELS (REC 290TP2 BLK) AND ONCVE CENTRSAL INVERTER (Ningbo Ginlong Solis 1p3k inverter, ginlong RSD).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2499	18041-10000-40827	5333 S MAIN ST	90037	9	108B201   561	5101034031	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2328.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	33.99352	-118.27411	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2500	13041-10000-27866	4232 N RHODES AVE	91604	2	165B165   816	2367007006	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.14776	-118.40288	PV1.  Install 6.25 kW DC Photovoltaic System.  Transformerless inverter: SolarEdge SE5000A-US.  20 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2501	14041-10001-30595	11105 N MCVINE AVE	91040	7	210B193   439	2551045001	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Expired	03/27/2017 12:00:00 AM	ADDRESS	34.27066	-118.31163	(3/2/2015) CHANGE OF DESCRIPTION.  (((INVERTER SIZE 5.0KW.)))PV 1 System size: 5KW with 18 modules(TSM-PA05.18 The Trinamont Module) and 1 inverter (3.3KW Solar Edge)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2502	15041-20000-23821	8436 W 3RD ST Suites 700-701	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.07301	-118.37448	Plan check for power and lighting. Project site is the 7th floor of an existing commercial high-rise building. Use of site will be an outpatient surgery center. Procedures include outpatient surgical procedures which may include the use of anesthesia. Plans to be checked for OSHPD-3 requirements. New generator is being installed on the roof to provide emergency power to the essential eletrical systems. Total lighting area = 7,470 sq. ft.Note: Building plan check under application number 15016-20000-15535	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2503	16041-10000-28350	2127 E CESAR E CHAVEZ AVE	90033	14	129A223   150	5175013002	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.04813	-118.21039	TI TO BAKERY SHOP. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2504	14041-20000-35615	6080 W CENTER DR #900	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	33.97713	-118.39172	TI TO AN EXISTING COMMERCIAL HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO THE 9TH FLOOR. TOTAL SQUARE FOOTAGE 8600.  PLAN CHECK FOR ENERGY AND EMERGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2505	14041-10000-11365	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK FOR ENERGY ONLY USING TAILORED METHOD. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. 10100SQRFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2506	11041-20000-03850	12745 W VAN NUYS BLVD	91331	7	210B161   139	2533019032	[Q]C2-1VL-CDO	North Valley	Arleta - Pacoima	Pacoima		1041.05, 1042.02	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	05/09/2011 12:00:00 AM		Permit Finaled	08/01/2011 12:00:00 AM	ADDRESS	34.27564	-118.41134	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR CHG OF USE FROM RETAIL TO RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2507	11041-10000-12691	16425 W VENTURA BLVD	91436	5	168B137   339	2260009043	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM			PC Approved	06/20/2011 12:00:00 AM	ADDRESS	34.15761	-118.49118	T.I. INTERIOR REMODEL OF (E) RETAIL  ( FEDEX OFFICES )PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2508	16041-20000-08621	18753 W GLEDHILL ST	91324	12	198B121   125	2763018021	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.24198	-118.5425	Plan check for a PV1 roof-mounted PV system. System size is (1) inverter, (15) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2509	18041-10000-02606	1999 S AVENUE OF THE STARS 15th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PC FOR OFFICE TI IN A HIGH RISE ON THE 15TH FLOOR FOR TITLE 24 ENERGY ONLY.   SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 11763 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2510	16041-30000-42699	633 W 5TH ST 62nd Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project site is the 62nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 11,375 sq. ft.Note: Building application has been generated under 16016-10000-28852	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2511	14041-20000-14935	21550 W OXNARD ST SUITE 200	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.179	-118.60001	Commercial office TI.  Relocation of (E) fixtures not exceeding 50% of the installed wattage in each space - plan check for Title 24 mandatory measures only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2512	13041-20000-32891	1238 S GENESEE AVE	90019	10	129B177   102	5086027022	R1-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.05341	-118.36218	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.6 KW AC USING 12 MICROINVERTERS. ENPHASE M215. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2513	14041-10000-35178	1786 N NORTH SPRING ST	90031	1	138A219   143	5447026002	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.07128	-118.22282	Full plan check for TI to (E) commercial building, conversion from light industrial to commercial office .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2514	17041-10000-17657	3234 S KELTON AVE	90034	5	120B157   352	4254018012	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/24/2017 12:00:00 AM	ADDRESS	34.02649	-118.41994	PC FOR ROOFTOP MOUNTED PV SYSTEM USIGN 44 MODULES, CENTRAL INVERTER RATED 13.5KW AC. SYSTEM USESPOWER OPTIMIZERS	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2515	15041-10000-40308	250 E 1ST ST	90012	14	130-5A213 150	5161016014	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.05038	-118.24114	TI TO ELEVATOR LOBBY. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2516	14041-10000-33246	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Issued	12/01/2014 12:00:00 AM	ADDRESS	33.74512	-118.26099	New Fire Alarm IN HEADWORKS reclamation plant (PORT OF LA, TERMINAL ISLAND) HAZARDOUS LOCATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2517	10041-20000-15847	10741 W SANTA MONICA BLVD	90024	5	129B153    23	4325030001	[Q]RD1.5-1-O, [Q]RD1.5-1VL-O	West Los Angeles	Westwood			2656.01	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM			PC Approved	08/13/2010 12:00:00 AM	PIN	34.05246051	-118.43369709	Revision to approved set of plan # 08041-30000-26291 changing feeder size for elevator and on secondary side of the 500kva trxfmr. ( Remodel of an existing Church bilding. Electrical Plan Check includesnew panels, lights, other loads and Title 24 energy calcs.  Variance to separate the electrical and fire alarm approvals and permits was submitted on March 26, 2009.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2518	18041-20000-45012	24214 S ROSCOE BLVD	91304	12	192B089   198	2017039009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.21939	-118.65455	Plan check for PV roof mounted system, system size: 2.835kW with 9 PV modules and 1 inverter(3.0kw)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2519	16041-20000-11276	16100 W MULHOLLAND DR	90049	11	159B141   389	4490001006	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.1299	-118.48421	Plan check for energy only. New P.E. Office, storage building, and play yard (covered breezeway) for athletic facility. New indoor (1,425sqft) and outdoor (10,000sqft) lighting (incl. emergency). Associated building permit numbers:16010-30000-0124716010-30000-0125016010-30000-01251	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2520	19041-20000-34777	777 S FIGUEROA ST 30TH FLR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	T24 PLAN CHECK FOR NEW LIGHTS IN RESTROOM IN EXISTING HIGH RISE BUILDING 30TH FLOOR. TOTAL SQUARE FOOTAGE = 750 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2521	14041-10000-17848	675 N FRONT ST	90731	9	021B201   203	7448035907	R4-1VL	Central			Y	2074.00	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	33.75	-118.28209	PC FOR POWER. REMOVE AND REPLACE ATS, GENERATOR, VFDs, PUMPs, MOTORs FOR CITY OF LA, SANITATION DEPARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2522	11041-20003-23441	10813 N ZELZAH AVE	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM			PC Approved	06/15/2012 12:00:00 AM	ADDRESS	34.26646	-118.52366	Changes from previously approved plans.  Changes in lighting only.  All changes indicate by Delta-9 as shown on plans.  Plan check for energy only.*****T.I. to existing retail space.  Install new 600A switchboard, subpanels, and branch circuits.  Install general/emergency lighting.  Plan check for energy and power.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2523	15041-10000-05903	4257 W 3RD ST	90004	10	135B193   197	5517008029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM			PC Approved	02/27/2015 12:00:00 AM	PIN	34.0691727	-118.30705886	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1772.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2524	15041-20000-10692	10619 N GAVIOTA AVE	91344	12	207B141   511	2668007009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.26345	-118.4827	Plan check for PV  adding new inverter and modules to  existing system. New systems are 1 inverter(PVI-5000-OUTD-US-Z-A) and 25 modules(KYOCERA # KU2606XPA) and new load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2525	17041-10000-01556	4501 S GLENCOE AVE	90292	11	105B153   614	4212007008	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	33.9849	-118.43588	PC for T-24 for office space area with 23039 sqft. Installing new lights and receptacles. Total connected load is less than 400 amp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2526	17041-20000-00369	9301 N TAMPA AVE #34	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Issued	03/21/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	"Plan check for energy only. Retail mall TI - Space #34 (""Finish Line""). New lighting (incl. emergency). 6,736sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2527	14041-10000-13682	1411 W 190TH ST	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	33.85852	-118.30317	Title 24 plan checkT.I. - Installation of 120v recepticles in new offices (highrise)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2528	14041-20001-01869	9930 N BARTEE AVE	91331	6	201B157    73	2645006017	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/02/2014 12:00:00 AM	ADDRESS	34.2509	-118.43232	((EXPEDITE FEES)))pv1 single faqmily dwelling. total system size 3.8kw ac using transformerless inverter with power optimizers total of 14 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2529	17041-20000-42873	19325 W VENTURA BLVD	91356	3	174B117   300	2163001018	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.17285	-118.55443	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2530	17041-20000-32207	12811 N WOODLEY AVE	91344	12	222B133   494	2609002025	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.30296	-118.49954	24.91$ permit fees due to senate bill 1222Plan check for solar pv system, roof-mounted on SFD.11.4kW ungrounded system. (45) 330W pv modules.Each module has a 400W power optimizer.Derating main breaker to 175A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2531	18041-10000-29105	7161 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	07/09/2021 12:00:00 AM	ADDRESS	33.94524	-118.41969	PC FOR POWER FOR INSTALLATION OF NEW PERIMETER FENCE LIGHTING AND MODIFICATION TO AIRFIELD LIGHTING VAULT AND NEW DISTRIBUTION PANEL FOR THE BEACON AND STORM FILTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2532	13041-20000-17766	11964 W VALERIO ST	91605	6	186B165   542	2317015012	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.20472	-118.39437	Plan check for energy only. Outdoor parking lot. Express permit for lighting, outlets, and four car chargers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2533	15041-10000-05335	8110 N WEBB AVE	91605	6	189B169    45	2310007020	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.21806	-118.38961	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  CHANGE EXISTING LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 11519.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2534	16041-30000-43737	941 N HIGHLAND AVE	90038	4	144B185  1015	5532012041	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Issued	05/18/2017 12:00:00 AM	ADDRESS	34.08829	-118.33879	Plan check for Title 24 only. Project site is an existing commercial building. Project scope restroom lighting. Total lighting area = 645 sq. ft.Note: Building application has been generated under 15016-10000-25354	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2535	16041-10000-39353	530 S SPRING ST #2	90013	14	129A211   182	5149036010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.04656	-118.25019	Full PC for power and energy. Change a portion of the retail space to a dental office. Scope includes a new 200A panel, new circuits, and new lights. Total affected area is 1232 Sq. Ft. B#16016-10000-25948	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2536	12041-10000-17948	3750 W SANTA ROSALIA DR Lobby-(ground)	90008	8	114B185  1258	5032022***	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Issued	08/01/2012 12:00:00 AM	ADDRESS	34.00802	-118.33889	Plan check for energy and emergency lighting. Office space. Low rise mixed use. Scope of work is in office space. Ground Floor. 2819 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2537	17041-10001-09892	680 W KNOX ST #170	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	33.85408	-118.28767	PC FOR ENERGY ONLY. CONNECTED LOAD <400 AMP. COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS 6650 SQ FT.pc for title 24 per inspection.B #17016-10000-02596	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2538	14041-20000-33552	19509 W HAYNES ST	91335	3	180B117   569	2132010002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.18984	-118.55831	PV1MICROINVERTER STANDARD PLAN SYSTEM SIZE 9.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2539	16041-20000-39214	16503 W NAPA ST	91343	12	195B137   896	2689001009	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.22673	-118.49195	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter, (22) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2540	19041-20000-22235	22135 W ROSCOE BLVD LOT #33	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 33.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2541	16041-10000-13488	12121 W WILSHIRE BLVD Suite 1200	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	PIN	34.04391963	-118.46825257	T-24, Tenant improvment to suite 1200. Located in a high rise building.  Scope of work includes new lighting and receptacles. Total sqft 4929ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2542	17041-20000-44072	12781 W VAN NUYS BLVD	91331	7	210B161   139	2533019032	[Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.27419	-118.4113	New lighting system in dining room of (E) commercial restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2543	15041-20000-11585	4203 S REDWOOD AVE	90066	11	108B153  1156	4230006023	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	33.98939	-118.43902	PLANCHECK FOR POWER. INSTALLTION OF 6 NEW PANELBOARDS WITH PLUGLOADS FOR IT EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2544	15041-10000-37964	1144 S CREST DR	90035	5	132B169   716	4332008022	R1-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.05588	-118.38769	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2KW INTERCONNECTED WITH MSP.(42) KYOCERA MODULES(2) PVI INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2545	12041-10000-05705	8575 W 3RD ST Parking #4	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.07372	-118.37914	T-24 and emergency lighting plan check canopy and parking area for Parking structure #4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2546	14041-10000-05701	1712 N KEMPER ST	90065	1	148-5A217 368	5455011005	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.10048	-118.23139	PV1, INSTALL 1.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(6) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2547	10041-10001-22340	11827 W VENICE BLVD	90066	11	114B157   942	4234016001	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.00775	-118.42664	Modification to an existing set of approved plans. Plan check is for energy and power.<<<<<<<New servcie of 600 amp, church building two new sub panels are added, title 24 was approved before but now modififed.  New approval for title 24 is requested.  Fault current from DWP submitted with 22000 Amp>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2548	14041-20001-35749	4824 N SUNNYSLOPE AVE Bld. 4D	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Issued	03/30/2018 12:00:00 AM	ADDRESS	34.15859	-118.42562	[[[ 3/30/18 CHANGES TO APPROVED SET.  DELTA 1 CHANGES. UPGRADING HOUSE BREAKER TO 1600AMPS, PANEL UPGRADE TO 225, ADDING 5 PUMPS, REVISING STREET LIGHTING ]]]]New 3 story apartment with 26 units and 3 level subterranean garage.  New 2000A service, panels, branch circuits, and lighting.    Plan check for power and energy.Note: variance to separate fire alarm plans submitted on 12/29/14.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2549	17041-10000-28378	13880 W DEL SUR ST	91340	7	210B153   197	2616019044	M1-1-CUGU, MR1-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.27473	-118.43483	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH LED FIXTURES FOR OUTDOOR USE.  TOTAL SQUARE FT 110,100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2550	13041-20000-35643	2017 S OCEAN FRONT WALK	90291	11	106-5A145 509	4226013006	(Q)C1-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	33.98441	-118.47142	T. I. FOR (E) RETAIL STORE. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2551	17041-20001-24972	9841 N AIRPORT BLVD GROUND-FLOOR	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	33.94647	-118.38626	Plan check for Title 24 only. Project site is the ground floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,810 sq. ft.Note: Original plan set was lost.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY ONLY.  UPGRADES TO GROUND FLOOR LOBBY. BUILDING PERMIT # 17016-10000-12771COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 02/03/17. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2552	19041-20000-42435	13408 N MANZANILLO LANE	91342	7	225B157  1054	2510026019	(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.31525	-118.42204	Plan check for PV roof mounted system, PV System size: 1.68KW with 7 PV Modules and 7 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2553	16041-20001-19805	10989 W ROCHESTER AVE 1-63	90024	5	132B153   800	4324006020	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/06/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.05561	-118.44536	EXPEDITEPV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2554	15041-10000-24790	5928 E YORK BLVD	90042	14	154-5A229 181	5484015001	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.20	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM			PC Approved	08/03/2015 12:00:00 AM	ADDRESS	34.11795	-118.18996	Energy plan check for a bakery store; Scope includes new lighting, receptacles and equipment. Total area is 1660-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2555	18041-10000-43591	11100 W SANTA MONICA BLVD 2nd Flr	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI IN EXISTING PUBLIC BATHROOMS ON THE 2ND FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2556	17041-20001-17760	3649 N WOODCLIFF ROAD	91403	4	162A145   203	2279014018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.13662	-118.46728	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.15.2kW ungrounded system. (54) 330W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2557	17041-10000-30861	10250 W SANTA MONICA BLVD # 2965	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant ""Asics"" on Westfield Century City Ste.#2965"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2558	10041-10000-11236	10201 W PICO BLVD BLDG 99	90035	5	129B161  1442	4315019012	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	INSTALLATION OF A ROOF-MOUNTED 161 KW PHOTOVOLTAIC SYSTEM;  SYSTEM CONSISTS OF 4 ARRAYS MOUNTED ON THE ROOF OF THE CRAFTS BUILDING ON THE FOX STUDIO LOT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2559	13041-20000-06945	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	PIN	34.03245819	-118.45766562	New multi-tenant buildling.  Service is being plan check on separate application.  However, this plan check will be required for service load sizing.  The building appears to  be multiple structures.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2560	18041-30000-14409	22414 W VANOWEN ST	91307	12	180B101    47	2038028033	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.19357	-118.61529	Plan check for a PV1 roof-mounted PV system. System size is 9.5 kWac-CEC/10.4 kWdc with a combined inverter output power of 10.4 kWac. System consists of (2) inverters, (33) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2561	15041-20000-23744	6050 1/2 N COLFAX AVE	91606	2	177B169   657	2334014041	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Apartment			07/24/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.18082	-118.38766	Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (9) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2562	10041-10002-08726	705 W 9TH ST 1st floor	90017		129A207   265	5144021040							Electrical	Electrical	Apartment			07/21/2010 12:00:00 AM			PC Approved	07/30/2010 12:00:00 AM	ADDRESS	34.04607	-118.2616	Changes from previously approved plans.  Changes include light fixtures.  Plan check for energy only ; permit was issued earlier.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2563	17041-10001-00091	3689 S WELLINGTON ROAD	90016	10	117B185   109	5046027008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.0202	-118.33842	02/06/17Changes to an approved set of plans. Changes include relocating modules on the roof, reducing the number of modules from 36 to 30, and changing model from Solarworld Solarworld SW290 to SW325. New system size is 9.75KWac.Note: Permit is paid under PCIS#17041-10000-00091	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2564	17041-10000-00516	333 S GRAND AVE 2200	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR ENERGYT.I. OFFICE, NO CHANGE OF USE, SONNECTED LOAD < 400A. TOTAL AREA 5319 SQ FT.B#16016-10000-30783	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2565	19041-10000-05324	14620 W TITUS ST	91402	6	192B149   539	2210011006	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.21964	-118.45146	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2566	13041-20000-23797	12877 N JOLETTE AVE	91344	12	222B129   151	2601045027	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Info Complete	09/10/2013 12:00:00 AM	ADDRESS	34.30383	-118.51462	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW AC USING 28 MODULES 2 CENTRAL INVERTERS TRANSFORMERLESS INVERTERS. POI AHEAD OF MAIN, VERIFY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2567	14041-20000-01481	10521 N SEPULVEDA BLVD	91345	7	207B145   574	2649013004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.26162	-118.46772	PV1 SINGLE FAMILY DWELLING. TOTA SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2568	19041-10000-39388	1365 N SUMMITRIDGE DR	90210	5	147B157   508	4355007010	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	12/14/2019 12:00:00 AM	ADDRESS	34.09536	-118.41989	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 40 MODULES (LG365Q1C-A5) AND 40 MICROINVERTERS (IQ7PLUS-72). SYSTEM SIZE IS 11.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2569	18041-20001-19181	4633 N CARITINA DR	91356	3	168B117   496	2178015023	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.15423	-118.55694	Expedited plan check fee. PV1.  Install 18.2 kW roof mounted grid tied PV system.  (56) modules with (1) 7.6 and (2) 5.2 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2570	11041-10000-25110	4569 W SANTA MONICA BLVD	90029	13	144B197   671	5542027030	C2-1D	Central	Hollywood	East Hollywood	YES	1913.00	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.09107	-118.28843	P/check for compliance with lighting reqmts. of T-24 including energency egress lights and exit signs.OFFICE TI, ADDING NEW 19' X 38' MEZZANINE, STAIRS, AND ADA RAMP. NEW SKYLIGHTS. REMOVE A 40' X 40' SECOND STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2571	19041-10001-22472	2007 W JEFFERSON BLVD	90018	10	120B189   675	5052023038	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	34.02567	-118.31541	PLAN CHECK ONLY, SCOPE OF WORK INCLUDES THE REMOVAL OF HVAC UNITS AND CHANGE OF EMERGENCY FIXTURES. NOTE CHANGES ON DELTA 2 ONLY. ______________________________________Energy plan check for a change of use from a (E) retail to an office/ art studio. Scope include new lighting and and equipmnet with a total lighing area of 904-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2572	10041-10000-25755	630 W HARRY BRIDGES BLVD	90744	15	027B205   442	7440006***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Public Safety Only			12/29/2010 12:00:00 AM			Corrections Issued	02/13/2011 12:00:00 AM	ADDRESS	33.77068	-118.26868	New Fire alarm for a 4 story office building for the port of LA. EPC is for power. (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2573	18041-20000-31337	11620 W CHENAULT ST	90049	11	132B145   223	4401024026	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Apartment			08/17/2018 12:00:00 AM	10/16/2020 12:00:00 AM		Permit Finaled	03/24/2023 12:00:00 AM	ADDRESS	34.05775	-118.46588	Power and lighting for new apartment building.  1000A 240/120V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2574	12041-10000-24185	8817 N PASO ROBLES AVE	91325	12	195B133   294	2690011005	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.23086	-118.50416	Install 11.44 kw roof mounted PV for a single family	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2575	15041-20000-28387	8541 N NEVADA AVE	91304	12	192B101   153	2010016015	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.22536	-118.60927	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2576	13041-20001-24246	550 S BEVERLY GLEN BLVD	90024	5	138B157    95	4359015020	RE20-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.07178	-118.43165	New 13kw Photovoltaic system for an existing single family dwelling.  Rooftop system.  System is UNGROUNDED.  Plan check/permit are for PV system only, Not for service panel upgrade or derating of main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2577	12041-20000-20876	5555 W MELROSE AVE 1st floor	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/04/2012 12:00:00 AM			PC Approved	09/04/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for energy and emergency lighting. Paramount Pictures. Office. 1st floor. 15526 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2578	19041-20000-06557	687 S HOBART BLVD SUITE B	90005	10	132B193   184	5093006035	(T)(Q)C2-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.0605	-118.30557	Plan check for power and energy. Project site is a tenant suite in an existing commercial building. Project scope is a first-time tenant. Total lighting area = 2,854 sq. ft.Note: Building application has been generated under 19016-20000-05207	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2579	17041-10001-06547	13222 S ESTRELLA AVE	90248	15	078B201    62	6132004007	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	12/16/2020 12:00:00 AM		Permit Finaled	04/15/2022 12:00:00 AM	ADDRESS	33.91185	-118.28599	FULL PLAN CHECK, CHANGE OF USE FROM OFFICE/WAREHOUE/MANUFACTURING TO HYDROPONIC AGRICULTURAL ENTERPRISE. SCOPE OF WORK INCLUDES EXISTING SERVICE, NEW PANELS, CIRCUITS AND LIGHTING. TOTAL SQ. FT. 40000. BLDG APPLICATION # 17016-20000-03732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2580	18041-20001-24223	2440 N VERMONT AVE	90027	4	153B197   193	5588028010	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.11537	-118.28988	08/01/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta D. Battery back-up configuration has been revised.*****Previous Work Description*****Installation of 40.5 kWh energy storage system for SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2581	13041-10000-10132	220 E 2ND ST BLDG A	90012	9	130-5A213 175	5161024014	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.04978	-118.2429	FIRE ALARM SYSTEM APARTMENT COMPLEX. PLANS ARE INCOMPLETE, CONTRACTER TO SUBMITTAL 2 WHEN PLANS ARE COMPLETE. PERMIT FOR 390 DEVICES AND TWO PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2582	16041-20001-17600	11954 W LOCKRIDGE ROAD	91604	2	156B165    31	2382007002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	06/02/2016 12:00:00 AM	ADDRESS	34.12694	-118.3929	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.87 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2583	13041-10000-23416	330 S HOPE ST INTERIOR-CPK	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			Corrections Issued	10/08/2013 12:00:00 AM	ADDRESS	34.05319	-118.25252	"PC FOR ENERGY ONLY. SIGN LIGHTING ONSITE. permit to be pulled at EPC counter only.  Two interior signs for CPK.1. INSTALL ONE (1) ILLUMINATED CABINET MALL SIGN, 36""X32""., SIGN READS ""CALIFORNIA PIZZA KITCHEN"". REFERENCE APP # 13048-10000-01854, BUILDING APPROVAL IN PENDING.2. INSTALL ONE(1) ILLUMINATED CABINET MALL SIGN, 12'X11"", SIGN READS ""CALIFORNIA PIZZA KITCHEN"". REFERENCE APP # 13048-10000-01822, BUILDING APPROVAL IN PENDING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2584	18041-20000-06499	10128 W HOLLOW GLEN CIR	90077	5	156B153   152	4382025***	RE15-1-H-RPD-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	01/19/2019 12:00:00 AM	ADDRESS	34.12309	-118.44225	Plan check for the addition of (2) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2585	12041-10000-30592	216 S ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM			Reviewed by Supervisor	01/31/2013 12:00:00 AM	ADDRESS	34.04645	-118.23792	New 600 Amp service for a commercial BLDG. New emergency generator for emergency lights, new panels, and circuits. EPC for power. Methane zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2586	09041-10001-11026	1150 S OLIVE ST GARDEN-LEVEL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM			PC Approved	01/14/2010 12:00:00 AM	ADDRESS	34.03962	-118.26181	REMODELING OF THE PATINA CAFETERIA ; REVISED LIGHTING PLAN  - RELOCATED LESS THAN 50% AND HAVING THE SAME LIGHTING CONTROLS AND LIGHTING DENSITY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2587	18041-20000-22499	741 S TOWNE AVE	90021	14	126A213   466	5146032047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.03874	-118.24629	Upgrading the sevice from 400 amps to 600 amps , fully rated  and all loads existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2588	16041-20000-42574	13075 W VICTORY BLVD	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.18684	-118.41708	new fire alarm system 6 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2589	12041-20000-27068	10901 W WILSHIRE BLVD # 100	90024	5	132B153   344	4363023032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Approved	11/09/2012 12:00:00 AM	ADDRESS	34.05884	-118.44466	T-24 lighting alteration to existing lighting system, to include relocated lighting and one new light.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2590	17041-10001-33183	5249 W CENTURY BLVD	90045	11	090B173    93	4128017044	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM	ADDRESS	33.94558	-118.37196	Supplemental plan check due to 4th verifcation time and additional power loads. **Master plan check by Mr.Zandi**Master is not approved yet, this is the 4th verification time**<<TI IN AN EXITING HOTEL. INSTALL A NEW 100AMP PANEL, CIRCUITS AND LIGHTS ON THE 1ST & 5TH FLOOR (FITNESS RM). PLAN CHECK FOR POWER AND ENERGY.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2591	15041-10000-35064	17338 W TOQUET DR	91316	5	165B133    52	2290026014	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.1524	-118.51023	ROOF-MOUNTED 7KW PV SYSTEM ON A SINGLE FAMILY HOME	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2592	14041-20001-22221	5533 N ALLOTT AVE	91401	4	174B157   721	2344005012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	34.17113	-118.42817	Modification to approved set.  Change of SLD to reflect existing main service panel conditions.  $0 submittal fee is due to Senate Bill SB-1222(((PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6800kW.(1) SolarEdge SE3800A-US transformerless inverter(1) SolarEdge SE3000A-US transformerless inverter(32) REC Solar REC260PE pv modules(32) SolarEdge P300 power optimizers)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2593	13041-20000-01520	22601 W SANTA SUSANA PASS ROAD	91311	12	210B101    11	2723002018	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.27227	-118.6163	Plan check for power and energy. Plan check fee for energy will be paid later. Equipment count per applicant, please verify during final fee period.REMODEL INTERIOR OF (E) SANCTUARY, LOBBY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2594	19041-20000-35390	555 S FLOWER ST 35TH FLOOR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for Title 24 only in existing highrise building 35th Floor lobby, restroom and corridors. Total area: 3037 sq ft. B#19016-10000-10182	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2595	14041-20000-28737	2912 S FIGUEROA ST	90007	9	121-5A203 213	5123019023	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.02528	-118.27761	NEW EXTERIOR LIGHTING TO A ONE STORY COMMERCIAL BUILDING.  3000SQFT. PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2596	15041-20000-25663	6316 N TOPANGA CANYON BLVD B-2140	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and energy 1st time tenant Topanga Mall. Total indoor area: 7,586 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2597	15041-20002-29142	4910 N ABBEYVILLE AVE	91364	3	168B093    82	2074022018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.1596	-118.63201	CHANGES TO AN APPROVED SET. RELOCATING THREE MODULES AND RELOCATING A DISCONNECT. PERMIT UNDER PCIS#15041-20000-29142/E15VN02477(((Installation of new roof mounted solar PV array.  Total system size = 11.61 kW.  Central inverter system with 43 modules.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2598	11041-10000-12705	548 S SPRING ST UNIT 114	90013	9	129A211   273	5149036017	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.04615	-118.25058	CHANGE OF USE FROM RETAIL TO RESTAURANT IN AN EXISTING HIGH-RISE BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2599	16041-10001-36735	4853 W GLENCAIRN ROAD	90027	4	153B197   310	5588012028	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	34.1142	-118.29647	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.6KWdc / 11.2KWac.(35)AC MODULES-SPR-X22-360-C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2600	14041-10000-12069	210 W 7TH ST #2	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			Corrections Issued	05/06/2014 12:00:00 AM	ADDRESS	34.04461	-118.25275	T24 FOR SIGN INSTALLING FOR CVS PHARMACY. #2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2601	16041-10001-30699	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Info Complete	05/01/2017 12:00:00 AM	ADDRESS	33.97811	-118.39245	Revision to approved set:, noted under Delta-6:  Adding (N) 4000A switchboard for future tenants, No changes on the load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2602	14041-10000-15559	5750 W WILSHIRE BLVD	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.06227	-118.3542	PLAN CHECK FOR ENERGY ONLY FOR EXSTING LOBBY AND VALET PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2603	18041-20000-33743	611 S GAYLEY AVE	90024	5	135B149   217	4363006021	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.06777	-118.44876	Plan check for a fire alarm system for a 4-story, 22-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (72) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2604	13041-10000-00491	14811 W SUTTON ST	91403	5	165A149    10	2276018018	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	34.14833	-118.45649	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A 2 STORY HOUSE. 45 MODULES IN 4 STRINGS USING 2 INVERTERS. SYSTEM SIZE IS 11.03 KW. SYSTEM IS NEGATIVELY GROUNDED [MODULES: YINGLI ENERGY  # YL245P-29B |||| INVERTERS: POWER-ONE # PVI-4.6-1-OUTD-S-US-NG]  *See application comments*	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2605	18041-10000-38420	3415 S SEPULVEDA BLVD 720	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.02055	-118.42347	PC FOR ENERGY ONLY, TI TO EXISTING SUITE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2606	17041-10000-41772	5121 N VAN NUYS BLVD	91403	4	171A151    87	2263034014	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.16387	-118.4489	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2607	18041-10000-31596	608 E 59TH ST	90001	9	105B205   172	6007005001	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	33.98705	-118.26463	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2608	16041-10001-24492	617 N DILLON ST 1-49	90026	13	141A203   375	5401014013	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.07899	-118.27903	PC only, change of an approved set equipment (honeywell panel), changes under delta 1 only. battery cal has been reduced.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2609	19041-30000-35239	501 E 60TH ST	90003	9	105B205   386	6006027019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	03/05/2021 12:00:00 AM	ADDRESS	33.98529	-118.26617	PC FOR PV-1 SYSTEM. SYSTEM INCLUDE 8 SOLAR PANELS WITH OPTIMIZERS (SOLAR EDGE P320). AND 1 - SE3000H CENTRAL INVERTER. TOTAL SYSTEM SIZE IS 3KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2610	12041-10000-15577	770 W WILSHIRE BLVD	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			PC Info Complete	07/05/2012 12:00:00 AM	ADDRESS	34.04914	-118.25811	Tile 24 and emergency lighting for 6th floor. pc only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2611	10041-20000-20262	11645 W WILSHIRE BLVD #800	90049	11	129B145   503	4265001036	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM	12/06/2010 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	PIN	34.05007845	-118.46045216	PLAN CHECK POWER AND ENERGY FOR TI OF EXIST 3174 SQ FT  MEDICAL SUITE 800.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2612	19041-10000-48678	325 E FLORENCE AVE	90003	9	102B205   795	6011008027	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Apartment			11/25/2019 12:00:00 AM	08/11/2020 12:00:00 AM		Permit Finaled	11/18/2022 12:00:00 AM	ADDRESS	33.97488	-118.26858	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 1200A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, 31 NEW PANELBOARDS, NEW CIRCUITS, NEW LIGHTS. TOTAL AFFECTED AREA IS 6553 SQ. FT.  (NEW 5 STORY MIXED USE 5 STORY 31 UNIT APARTMENT WITH RETAIL/OFFICE/GARAGE ON THE FIRST LEVEL.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2613	14041-10000-14258	5702 S BROADWAY	90037	9	108B201  1132	5101025014	C2-1VL	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	33.99041	-118.27809	TENANT IMPROVEMENT FOR OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2614	19041-20001-12703	8124 N RHODES AVE	91605	2	189B165    55	2309002018	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM			PC Approved	04/19/2019 12:00:00 AM	ADDRESS	34.21846	-118.40294	Expedited plan check fee.PV1.  Install 8.10 kW roof mounted grid tied PV system and 9.8 kWh energy storage system.  (27) modules with 7.6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2615	10041-10000-01589	6282 W HOLLYWOOD BLVD	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.1014	-118.32618	Change of use from retail to restaurant.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2616	16041-10000-45863	7820 W ELLENBOGEN ST	91040	7	210B193   330	2552013018	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.27151	-118.30365	PV1 3.8KW roof-mounted system with (1) central inverter, (15) modules and  power optimizers interconnecting through the service	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2617	10041-10000-17190	5413 S AVALON BLVD	90011	9	108B205   466	5101002900	OS-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Closed	02/21/2012 12:00:00 AM	ADDRESS	33.99298	-118.26538	INSTALL A TEMP.  800 AMP SERVICE FOR BUILDING 71 WHILE THE MAIN 1600 AMP SERVICE IS BEING DEMOLISHED AND REPLACED WITH NEW SERVICE EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2618	14041-20000-14006	6053 W CENTURY BLVD SUITE 200	90045	11	093B169   305	4124030902	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	33.94648	-118.38998	PLANCHECK FOR T24 ENERGY. TENANT IMPROVENT FOR COMMERICAL OFFICE AT LOS ANGELES WORLD AIRPORT. 375 SQFT. SUITE 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2619	19041-10000-51967	2057 W CENTURY BLVD	90047	8	091-5A191  60	6057020024	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/24/2021 12:00:00 AM	ADDRESS	33.94563	-118.31554	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2620	10041-10000-11082	2701 N SEPULVEDA BLVD	90049	11	156B141    17	4490001015	PF-1XL, RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	1415.00, 2623.01	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.12326	-118.4793	new fire alarm for a 5 story commercial bldg.  245 devices and 2 panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2621	18041-10001-20031	755 S LOS ANGELES ST	90014	14	127-5A211 253	5145001013	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Closed	12/14/2021 12:00:00 AM	ADDRESS	34.04231	-118.25201	Change to approved set by modifying the single line, power and lighting plan. Load calculation being updated. lighting area also being expanded. all changes under delta-A only.(((CORE/SHELL FOR (E) 5-STORY MIXED-USE WITH 3000-AMP SERVICE : BASEMENT TO 1ST FL AND MEZZ WILL BE RETAIL/RESTAURANT; 2ND FLOOR TO 5TH FLOOR WILL BE OFFICES; ROOF WILL HAVE A RESTAURANT. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2622	19041-10003-07098	15815 W MONTE ST #105-#106	91342	7	225B141  1525	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Issued	10/25/2019 12:00:00 AM	ADDRESS	34.31113	-118.47563	"DELTA ""1"" Changes to Approved plans. Scope of work: Removing most of the loads from Panel ""HA"". Installing a new 200Amp subpanel with no connected load and T-24 energy for a new ""Changing"" Room 280SFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2623	10041-10001-02720	15853 W MONTE ST 107C	91342	7	225B141  1523	2604003043	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	07/13/2010 12:00:00 AM	ADDRESS	34.31022	-118.47637	Delta 1 - Changes to the approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2624	16041-10000-01169	3705 W SUNSET BLVD	90026	13	145-5A203 457	5429021034	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.09079	-118.27782	Change of use from Retail to Restaurant. All electrical equipments are existing. This is PC only for T-24 only. Total area: 5192 sq.ft (indoor+non sale canopy)Permit under: 15041-10000-41741, and 15041-10000-42402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2625	16041-10000-04612	1800 CENTURY PARK EAST	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Info Complete	02/09/2016 12:00:00 AM	PIN	34.06270629	-118.4150769	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 6TH FLOOR (OFFICE/LOUNGE/RESTROOM SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES ON THE 6TH FLOOR, SUITE 600. TOTAL AFFECTED AREA IS 2063 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2626	16041-20000-17696	1157 S BUNDY DR	90049	11	126B145   135	4264026030	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.04464	-118.46824	(N) fire alarm system for 4-story 33-unit apartment building over subterranean garage.  New FACP with (94) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2627	11041-10000-02348	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM			Corrections Issued	02/17/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	New 600 Amp service & panels for a restaurant. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2628	15041-10000-03317	5560 W MANCHESTER AVE	90045	11	096B173   122	4126001011	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	33.95967	-118.37849	Plan check for power and title 24.  Total area = 80,756 sq. ft.Installation of pole lighting and electrical distribution system for existing parking lot space.  New 600 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2629	11041-10000-15226	10610 W MAGNOLIA BLVD	91601	2	171B177   723	2419016031	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	ADDRESS	34.16469	-118.36201	T.I.  Existing 7-11 replacing the light fixtures in the retail area only.  T-24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2630	18041-10000-13080	1130 S FIGUEROA ST PODIUM	90015	14	127-5A207 344	5138015045	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM			Reviewed by Supervisor	07/19/2018 12:00:00 AM	ADDRESS	34.04261	-118.26574	[1 OF 3]  Changes to approved set (Refer to plan check# 15041-10004-26434), Plan check fee on this plan  ALSO covered the plan check fee for Tower 2 and Tower 3. Only one set of plan provided for Tower 2, Tower 3, and Podium under this SOW. Master plan #15041-10004-26434 and narrative of changes are attached to this submittal.   plan check approved set with RTI under  18041-10000-13080	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2631	15041-20000-00984	7830 W TORREYSON DR	90046	4	159B173   626	5570017010	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2015 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.12898	-118.3709	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service pannel.(20) Axitec AC-300P modules(1) Power one PVI-6000 inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2632	12041-10000-28834	24301 W OXNARD ST	91367	3	177B089   586	2045002023	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.17974	-118.65476	PV1:  9.36 KW PV system for a single family residence.  Applicant is using the standard plan.  Plan check was done at the counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2633	14041-10000-10044	11829 W CULVER BLVD	90066	11	111B161  1042	4233022015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	33.99679	-118.41674	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KWAC. SERVICE SIZE IS 400A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2634	19041-20000-53017	5365 N ELLENVALE AVE	91367	3	171B089    90	2047016011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.16792	-118.65384	PV1.  Install 11.34 kW DC / 10.0 kW AC roof mounted PV system.  (36) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2635	14041-20000-03179	9942 W ROSCOE BLVD	91352	2	192B181    77	2403006008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Expired	03/01/2016 12:00:00 AM	ADDRESS	34.22297	-118.3475	PV1 SINGLW FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2636	19041-10000-00802	1010 N SEWARD ST	90038	13	144B185   912	5533012017	MR1-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.08928	-118.33305	PLAN CHECK FOR POWER AND ENERGY FOR NEW 6 STORY PARKING STRUCTURE. SCOPE OF WORK INCLUDES NEW 1000AMP SERVICE 277/480 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 124202 SQFT. BLD# 18010-10000-02705	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2637	14041-10001-16723	1601 N VINE ST	90028	13	148-5A187 301	5546009906	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO SINGLE LINE TO INDICATE SERIES RATINGS BEING USED. PC ONLY. PERMIT ALREADY ISSUED FOR SCOPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2638	16041-10000-28877	10275 N TUJUNGA CANYON BLVD	91042	7	204B197   923	2558021031	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.25466	-118.29122	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES TI-24 ONLY. TOTAL AREA: 31,194 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2639	16041-10000-37982	555 W 5TH ST 29TH FLOOR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	BATHROOM REMODEL AND CORE AND SHELL WORK. WORK DONE ON 29TH FLOOR. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2640	16041-10000-26269	3500 W 6TH ST #226	90020	10	135B197  1016	5502030016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Info Complete	07/26/2016 12:00:00 AM	ADDRESS	34.06346	-118.29849	Plan check for Energy (T-24) only.  TI in an existing food court, Suite 226 approximately 435 SF. Install new lights, receptacles, and kitchen equipment, new connected load < 400A.(B# 16016-10000-16707)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2641	12041-10000-13208	2100 E PACIFIC COAST HWY	90744	15	033B213    10	7428007009	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Issued	12/07/2012 12:00:00 AM	ADDRESS	33.79122	-118.23692	"***NEW PLANS SUBMITTED BEFORE REVIEW (ASSIGNMENT OF PLANS). 2 NEW BRANCH CIRCUITS ADDED FOR A TOTAL OF 4 BRANCH CIRCUITS. PLEASE REFLECT THIS CHANGE IN THE ""FINAL"" FEE PERIOD ***Plan check for power and energy. Two branch circuits in a Class I hazardous area (one of the branch circuits is for outdoor lighting). Site is also a Methane Hazard Site. Penetration of berm(s) (Electrical). 500sqft outdoor lighting."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2642	17041-20000-16286	11620 W WILSHIRE BLVD 280	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.05021	-118.45963	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR MEDICAL OFFICE. 1991 SQFT. SUITE 280.building permit # 17016-10000-06973	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2643	14041-20000-31707	318 N BELLINO DR	90272	11	129B117   164	4416014031	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.04531	-118.56088	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.0KW INTERCONNECTED WITH MSP.(32) SILIKEN SLK60PGL MODULES(1) SMA AMERICA SB7000US INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2644	15041-10000-03995	1114 E 8TH ST # 108	90021	14	124-5A213 367	5146019007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Issued	02/10/2015 12:00:00 AM	ADDRESS	34.03501	-118.24516	T24 only. remove hid light fixtures and replace with LED fixtures. total area 1056 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2645	12041-10001-02932	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	ADDRESS	33.97704	-118.40702	"REVISED PERMITTED SET OF PLANS((((((((((((PLAN CHECK POWER ANND ENERGY FOR INTERIOR TENANT IMPROVEMENTS ""YOU TUBE"" BROADCAST STUDIO AND OFFICE.  SITE IN METHANE ZONE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2646	16041-10000-16852	15510 W LEMARSH ST	91345	7	204B145   552	2660003040	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.25536	-118.46998	Final Fee $0 due per California Senate Bill 1222PV1, rooftop solar installation 13.6 kW AC.  (46) SPR327NE       (1) SB6000TL-US   (2) SB3800TL-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2647	10041-10001-24876	4501 W COLORADO BLVD BLDG B-1	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM			PC Approved	06/24/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	Modifications to approved set: rerouting of conduits due to obstructions encountered during installation.  Relocation of some equipment.  Hazardous areas not to have changed.Lighting system installed wattage remain the same  Original Work Description: INTERIOR RENOVATION OF EXISTING MANUFACTURING AREA. ADD CIRCUITS, MOTOR, AND RELOCATE LUMINAIRES. NO NEW PANEL ADDED. SOME PANELS ARE LOCATED IN HAZARDOUS AREA. EPC FOR POWER AND ENERGY. (BLDG#1)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2648	14041-20000-08475	12777 W JEFFERSON BLVD	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	33.9778	-118.41768	permit to be pulled at EPC counter only. TI (E) BLDG A. PLAN CHECK FOR ENERGY ONLY. Less than 400A per applicant. Installing 3 new panels and 75 kva transformer in bldg A. changes on plan: light changed to emergency to meet 40:1 ratiofees under inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2649	15041-20000-18586	16632 W KALISHER ST	91344	12	213B137   801	2682012006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.27766	-118.49461	Plan check for PV roof mounted system. System size: 7.6kW with 29 modules and 1 inverter(7.6kW). Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2650	18041-20000-34680	6549 N RANCHITO AVE	91401	2	180B153   627	2238018009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.19003	-118.43575	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2651	16041-20001-38511	12205 N HONDERO CT	91344	12	219B125   106	2601074013	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM			PC Approved	11/14/2016 12:00:00 AM	ADDRESS	34.29526	-118.52723	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (2) inverters, (66) modules, (1) load center, and (2) combiner boxes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2652	12041-10001-01816	2131 N HILLHURST AVE	90027	4	150B197    76	5590003040	C4-1D	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.11109	-118.28759	SUPPLAMENTAL TO ORIGINAL PC UNDER 12041-10000-01816PC ONLY FOR UPDATED T24 PAGES AND FIXTURES.NEW 2-STORY + BASEMENT OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2653	14041-20000-17561	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	33.76597	-118.28407	T.I. to an (partial) existhing warehouse.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2654	13041-10000-24876	1025 S WESTWOOD BLVD	90024	5	132B149    25	4363018028	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Expired	02/01/2016 12:00:00 AM	ADDRESS	34.06197	-118.44565	TITLE 24 PLAN CHECK ONLY. 2615 SQFT. EMERGENCY LIGHTING. R. 2 STORY BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2655	11041-10000-09464	8500 W BEVERLY BLVD #820	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Finaled	04/16/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT TO (E) RETAIL SPACE (#820):  (N) INTERIOR NON-BEARING WALLS, CEILING SYSTEMS, MILLWORK AND FINISHES TO CREATE SALES AREA, STORAGE, RESTROOMS AND FITTING AREAS.  INCLUDES REMOVING ESCALATOR, ENCLOSURE AND PIT.  (26,363 SF)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2656	17041-10001-19571	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022058	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Re-Activate Permit	09/05/2018 12:00:00 AM	ADDRESS	34.21384	-118.44905	Permit Withdrawn on 7/17/2018 per applicant's request. The FA system WILL NOT be installed.<<<<Plan check and supplemental permit to permit# 17041-10000-19571. Install New F.A. system with voice evacuation, (3) panels  (142) devices.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2657	14041-20000-21582	13502 W RAVEN ST	91342	7	225B157    73	2510006027	RA-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.31727	-118.42715	PV1 SFD. TOTAL SYSTEM SIZE 4.2 KW AC USING 14 MDOULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2658	18041-20000-17007	5335 S 8TH AVE	90043	8	108B189   472	5006018008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	01/18/2022 12:00:00 AM	ADDRESS	33.99402	-118.32592	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (14) modules, (1) battery, (1) auto-transformer, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2659	17041-10000-17540	525 S HARBOR BLVD	90731	15	015B201    51	7455026052	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.73952	-118.28004	Title 24 plan check.  Remove HID fixtures and replace with LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2660	17041-20000-12468	22121 W CLARENDON ST	91367	3	174B101   372	2169026110	CR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Apartment			04/17/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.16978	-118.60882	Plan check for power and energy. Project site is a new parking stucture. Work includes new 3,000-amp distribution equipment and a total lighting area of 208,092 sq. ft.Note: Building application has been generated under 17010-20000-01472	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2661	14041-10001-14109	12912 W SHERMAN WAY	91605	2	183B161    47	2327018072	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	Commercial			07/08/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.20103	-118.41414	Revision to an approved set of plan  for T24. night light were taken off and 4 unit equiments are added. <<CHANGE OF USE FROM RETAIL TO BEAUTY NAIL SALON,PLAN CHK IS FOR TITLE 24>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2662	17041-10000-10723	3907 S GIBRALTAR AVE	90008	10	117B177   250	5030002901	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.01641	-118.35488	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 7,475. Total of 15 light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2663	12041-20000-12666	9434 W CHEROKEE LANE	90210	5	150B165    67	4387032016	RE15-1-H, RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Issued	06/25/2012 12:00:00 AM	ADDRESS	34.11079	-118.40008	Modification to previously approved set of plans.  Relocate standby generator to lower level of garage in open air, and install new panels for car wash.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2664	15041-10001-13536	11400 S FIGUEROA ST	90061	8	087A201   308	6088004028	C2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	33.93079	-118.28234	Supplemental PC only . T-24 for outdoor lighting at Jack in the Box 3580. Total area: 33,130 sq. ft. Permit under 15041-10000-13536.***REPLACING EXISTING EXTERIOR AND PARKING LOT LIGHTS W/ LED.S	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2665	15041-10000-16997	595 E VENICE BLVD BLDG 1	90291	11	108B145  1466	4241037012	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	33.99003	-118.46131	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2666	16041-20001-32695	415 S LE DOUX ROAD 1-19	90048	5	138B173  1050	4334016038	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			06/26/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.07126	-118.37768	06-26-2019 Changes to an approved set of plan, Changes include additional mechanical  load additonal of panel, circuits and motor.  All changes has been clouded as delta C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2667	12041-10000-14179	2020 N REDESDALE AVE	90039	4	147A207    71	5431020014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00, 1954.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.0954	-118.2668	Plan check for new roof mounted 5.28KW Enphase M215 Microinverter photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2668	11041-10000-18601	12820 W PANAMA ST	90066	11	105B157   395	4223008012	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	33.98477	-118.42659	REMODEL COMMERCIAL SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2669	19041-30000-07789	21150 W DUMETZ ROAD	91364	3	168B105   340	2172002002	A1-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.15831	-118.59156	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the 1st and 2nd floors. Total lighting area = 6,653 sq. ft.Note: Building application has been generated under 19014-30000-00481	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2670	17041-20000-37276	20929 W VENTURA BLVD	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2671	19041-10000-50025	11107 W LANDALE ST	91602	4	165B173   149	2423011016	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Expired	08/30/2021 12:00:00 AM	ADDRESS	34.15147	-118.37254	Plan Check for PV-1 system, system size 8.190KW, (26) Modules with microinverters .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2672	16041-20002-07191	10914 N DARBY AVE	91326	12	210B125   700	2715004019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.26864	-118.53368	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 5 kWac onto the existing 5 kWac, for a total system size of 10 kWac. Addition consists of (1) inverter, (22) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2673	18041-10000-33838	11018 N BAIRD AVE	91326	12	210B125   521	2717014012	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.27034	-118.53708	PLAN CHECK FOR ROOF MONTED PV SYSTEM USING 32 AC MODULES (SUNPOWER SPR-X22-360-D-AC). SYSTEM SIZE 10.273 WITH MONITORING SYSTEM	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2674	15041-20000-29035	17820 W SAN JOSE ST	91344	12	207B129   907	2733002005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.26109	-118.52223	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2675	09041-10001-05908	1460 N VINE ST	90028	13	147A189    91	5546025015	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM			PC Approved	04/13/2010 12:00:00 AM	ADDRESS	34.09734	-118.32646	Changes to T-24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2676	19041-20000-36669	5913 3/4 W WILLOUGHBY AVE	90038	14	141A237   452	5220021014	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.08722	-118.32489	Plan check for PV roof mounted system, PV system size: 11.84KW DC, 10.667KW AC with 32 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2677	14041-20000-25279	11165 N SEPULVEDA BLVD	91345	7	210B145    69	2664007012	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.27418	-118.46814	TI OF OFFICE. NON MEDICAL. NEW LIGHTING. PLAN CHECK FOR T24 ENERGY ONLY. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2678	19041-10001-50725	4206 S LINCOLN BLVD	90292	11	105B153    48	4230001019	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Issued	12/10/2019 12:00:00 AM	ADDRESS	33.9868	-118.4441	SUPPLEMENTAL PERMIT TO 19041-10000-50725 TO REMOVE ADDITIONAL CONTRACTOR AND ENGINEER.  $0 PERMIT FEES DUE TO DEPARTMENT ERROR. ( MASTER APP. 19041-10000-50725)_________________________________________________________________________PLAN CHECK FOR FOR TITLE 24. SCOPE OF WORK INCLUDES NEW LIGHTING FIXTURES AND CIRCUITS. TOTAL AFFECTED AREA: 1980 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2679	15041-20000-19271	7617 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.20914	-118.46494	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 3.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2680	17041-20000-25317	13221 N WHISTLER LANE	91344	12	225B133   224	2602003002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.30987	-118.50603	Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (42) modules, (42) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2681	18041-10000-34557	777 S FIGUEROA ST 48TH FLOOR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Energy plan check for an office TI located on the 48th floor of a commercial building . Scope include new lighting and equipment with a total area of 13947-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2682	10041-10000-14834	2700 W COLORADO BLVD # 145	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	08/24/2010 12:00:00 AM	ADDRESS	34.14248	-118.22438	TI IN RETAIL PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2683	19041-10000-04528	11502 S VERMONT AVE	90044	8	084B197    35	6088009002	C1-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.92989	-118.29137	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2684	11041-10000-20870	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.02174	-118.39786	New 131 unit, 6-story apartment building, with 3 levels of underground parking.  Fees calculated per customer application.  Plan check for Power and Energy.  A variance to seperate the fire alarm system from the electrical system was submitted on May 24, 2012..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2685	19041-20001-22443												Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM			PC Approved	07/15/2019 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2686	19041-20000-25127	10074 W SULLY DR pv1	91352	2	189B181    75	2403019012	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.218	-118.34978	$0 permit fee due to SB1222 and AB 1414pv1 plan check for installing a roof  mounted pv system on existing sfd. system size is 12.685 KW DC/11.4KW AC with (1) 5KW ESS interconnected with msp. scope of work includes (43) solar world pv modules with P320 optimizers, a SE3800H inverter, a SE7600A inverter, a LG Chem RESU10H battery, and a 60A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2687	13041-20000-26172	7112 N LASAINE AVE	91406	6	183B133   300	2228030025	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.19958	-118.51087	pv1 single family dwelling. total system size 4.2 kw AC using 22 modules. using transofrmerless inverter nonstandard plan. 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2688	12041-10001-05398	500 S VIRGIL AVE #201	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM			PC Info Complete	05/10/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	DELTA CHANGES TO APPROVED PLANS.  RELOCATE ONE EXIT SIGN AND ADD THREE LIGHTS.T.I. to an existing Office, physical therapy only - no blood work or x-rays.  Changing lights, adding receptacles.  PLAN CHECK ONLY for Energy.  Suite #201 for a 4-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2689	11041-10001-05626	100 S WESTERN AVE	90004	10	138B193   964	5517006001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.07344	-118.30897	REVISION TO APPROVED SET OF PLANS- CHANGE IN THE LIGHTING SYSTEM WITH THE USE OF 2X2 FLUORESCENT LUMINAIRES. NOTE THAT AT THIS TIME PERMIT HAS NOT BEEN OBTAINEDINTERIOR REMODELING OF EXISTING RESTAURANT-  SHIK DO RAK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2690	14041-20000-27067	9750 S AIRPORT BLVD	90045	11	093B169   274	4125024020	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM			PC Approved	10/01/2014 12:00:00 AM	ADDRESS	33.94789	-118.38556	TI TO AN EXISTING HOTEL BUILDING, SEVEN FLOORS.  REPLACE LIGHTING IN BATHRROMS AND VENDING AREAS ON ALL SEVEN FLOORS OF THE EAST WING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2691	13041-10000-19323	2481 N LILLYVALE AVE	90032	14	139-5A237  65	5220034026	PF-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.0765	-118.16477	FIRE ALARM SYSTEM ADDITION, 13 DEVICES WITH 1 PANEL IN A  2-STORY COMMERCIAL BUILDING . ADDRESS PER APPLICANT. THE BUILDING IS FULLY SPRINKLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2692	16041-10000-45096	380 W WORLD WAY NORT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			Corrections Issued	01/19/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check for Duct bank no cables  install at LAX for future use. plan check only highlighted area(C16-11, C16-09), other sheets are detail for the duct bank. Talk to Nabil.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2693	19041-20000-17041	12255 W RICHWOOD DR	90049	11	138B141   420	4494002013	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	11/21/2022 12:00:00 AM		Permit Finaled	03/22/2024 12:00:00 AM	ADDRESS	34.07227	-118.47973	NEW SINGLE FAMILY DWELLING WITH 600A SERVICE. PLAN CHECK FOR POWER AND ENERGY.SCOPE OF WORK INCLUDES NEW 600A SERVICE, 600A PANEL, A 225APANEL, (3) 200A PANELS, (3) 100A PANELS, A 5HP ELEVATOR MOTOR, A 100A TESLA CHARGER, AND A 22KVA NATURAL GAS GENERATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2694	16041-10000-23276	5955 W SATURN ST 1-29	90035	10	129B173   629	5068012039	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			07/01/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.05039	-118.3702	NEW 4-STORY (TYPE VA) APARTMENT (29 UNITS) BUILDING.FULL PLANCHECK AND TITLE 24 (23242SQ. FT.), SERVICE 1200A3 TYP UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2695	14041-10000-14780	360 W AVENUE 26 SUITE 118	90031	1	141A221   613	5205012183	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.08097	-118.21997	PLANCHECK FOR T24 ENERGY.   FIRST TIME TENANT WITH MEZZANIE. SUITE 118. 1751 SQFT, EMERGENCY LIGHITNG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2696	13041-10000-28770	3227 S MAPLEWOOD AVE	90066	11	114B149   275	4247006035	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.01051	-118.4523	PV1. ROOF MOUNTED 9KW PHOTOVOLTAIC SYSTEM. 2 STORY HOUSE. STANDARD CENTRAL INVERTER PLAN. (36) HANWHA # HSL60P6-PB-4-250TW(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2697	13041-10000-03990	8231 W 3RD ST SUITE E	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.07272	-118.36914	POWER+ENERGY TI 1ST TENANT SPINCYCLE STUDIO (12016-20000-25795). 3 stories. methane but no underground work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2698	17041-10000-31495	2029 S CENTURY PARK EAST 1040	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHECK FOR TITLE 24 ONLY - TI FOR OFFICE SPACE TO FFICE SPACE - TOTAL AFFECTED AREA 2842 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2699	13041-20000-03794	11272 W MAGNOLIA BLVD	91601	2	171B173   667	2353003803	C4-1-CA, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.16475	-118.37695	Plan check for power only. No energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2700	15041-10000-27502	1143-1147 S WESTWOOD BLVD	90024	5	132B153   267	4363023029	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.05993	-118.44523	NEW FA DEVICES FOR A COMMERCIAL BUILDING WITH 16 DEVICES AND ONE FA PANEL AND ONE COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2701	13041-10000-13498	228 S MCCADDEN PL	90004	4	135B185    30	5513029005	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.07005	-118.33703	PV1. Plan check for new 11.118 kW DC roof mounted photovoltaic system. Transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2702	14041-10000-19490	18433 W ROSCOE BLVD SUITE #101	91325	12	192B125   578	2786022035	QC1-1VL, QP-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.22091	-118.53469	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NOT A PATIENT CARE ACCORDING TO APPLICANT. 830 SQFT, EMERGENCY LIGHTING.  SUITE 101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2703	12041-20000-04940	15505 W CHATSWORTH ST	91345	7	207B145   279	2649001004	(T)(Q)C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1093.00	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.26473	-118.46973	New unmanned telecommunication center.  Variance is filed to seperate the fire alarm.  New 800 amp seervice AIC on planned was more than number of DWP, fully rated system above the required AIC.  This plan check for power and T24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2704	19041-30000-14870	11753 W IOWA AVE	90025	11	126B149  1332	4262013075		West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Apartment			04/23/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	06/29/2023 12:00:00 AM	ADDRESS	34.0409	-118.45527	Plan check for power and energy. Project site is 3-story, 7-unit condo building over 1 level of basement parking garage. Work includes a 600-amp service and a total lighting area of 10,028 sq. ft.Note: Building permit has been issued under 14010-10000-00845	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2705	10041-20000-03474	1609 S WESTWOOD BLVD	90024	5	129B153   154	4324026024	C4-1VL	West Los Angeles	Westwood			2655.20	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM			PC Approved	02/26/2010 12:00:00 AM	ADDRESS	34.05258	-118.43966	Revisions to 09041-20000-20868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2706	15041-20001-04716	11309 W TIARA ST	91601	2	177B173  1251	2337010016	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.17864	-118.37716	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.  (27) KYOCERA MODULES(1) ABB PV-6000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2707	19041-10000-53303	3016 N MAIN ST	90031	1	135A223    26	5210024008	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	02/04/2022 12:00:00 AM		Issued	02/04/2022 12:00:00 AM				FULL POWER & ENERGY PC FOR A NEW 5000 AMP 480/277V 3PHASE 4WIRE NEW SERVICE. TOTAL AFFECTED AREA 37744sqft.***********************************************************************************PER BUILDING APPLICATION# 19010-10000-06106:New mixed use bldg with 97 DU in a 4 story type VA construction over 1 level of type 1A podium.  Ground floor shell for grocery store/retail.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2708	14041-10000-18289	2184 E OLYMPIC BLVD	90021	14	121-5A217 354	5167004035	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/08/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.026	-118.23363	plan check for power and energy for new building. hazardous location: propane tank. BLDG#14010-10-00053: 2,244 SQ.FT. PRE-FAB METAL BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2709	17041-10000-33492	1521 S HILL ST	90015	14	124-5A207 237	5134023001	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.03497	-118.26454	PC for T4 only for energy for church TI. Installing new lights.Total area of 5233sqft.Note: Permit is pulled under PCIS#17041-10000-21807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2710	13041-20000-35802	3501 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.02194	-118.28455	T24 FOR OFFICES AT USC. SCOPE OF WORK ON NORTH SIDE OF THIRD FLOOR AND SOME OFFICES ON THE FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2711	16041-20000-40312	1408 N POINSETTIA PL Unit #A	90046	4	147B181   927	5548019036	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.09607	-118.3481	Plan check for power only. New SFD - unit A - part of 5 attached SFDs fed from (N) common 600A service. House panel + loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2712	16041-10000-38826	18415 S EVELYN AVE	90248	15	060B193   117	6108007011	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	33.86316	-118.30271	PV1 SFD TOTAL SYSTEM SIZE 6.8KW AC USING AC PV MODULES. TOTAL OF 21 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2713	13041-20000-30410	3315 N CAHUENGA BLVD WEST	90068	4	159B181   570	2425026001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.13043	-118.35048	PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT. ((submittal 2 for expedite fees)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2714	16041-10000-07600	1443 S BONNIE BRAE ST	90006	1	127-5A201 202	5135007020	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2243.10	Electrical	Electrical	Apartment			03/03/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.04337	-118.28177	PC FOR POWER ONLY. CHANGE OF USE FROM 24 UNIT AND 15 GUEST ROOM TO 24 UNITS AND 15 LIGHT HOUSE KEEPING UNITS. SCOPE INCLUDES UPGRADING EXISTING SERVICE TO 600A 120/240V 3 PHASE 4 WIRE AND MAIN DISTRIBUTION BOARD. ALL OTHER ELECTRICAL EQUIPMENT ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2715	18041-20000-40548	16536 W MAYALL ST	91343	12	204B137   759	2678025025	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.25372	-118.49321	Plan check for a PV1 roof-mounted PV system. System size is 12.96 kWdc/11.52 kWac and consists of (36) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2716	17041-20000-43078	5195 N JEFFDALE AVE	91364	3	171B097   685	2075014031	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	Yes	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.16401	-118.62265	PV1.  Install 6.6 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2717	18041-10000-02563	400 WORLD WAY T-4	90045	11	090B161    16	4129027902	M3-1	West Los Angeles	LAX	Westchester-Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	33.94221	-118.40701	"Power plan check only, scope includes: >replace (2) 312KVA Motor Generators ""like-for-like"", and add (1) new motor generator with the same exat electrical rating as the other two.   >> replace a 1200A 575V 400Hz to NEW 2000A 575V 400Hz and reconnect all existing load from the old dist. board."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2718	12041-10000-19539	642 E 62ND ST	90001	9	105B205   810	6007010002	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	33.9831	-118.2631	Plan check T24 Energy for new lighting TI. Existing Sewing area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2719	12041-10000-15798	722 S ALAMEDA ST	90021	14	123A215   243	5166032029	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM			PC Approved	07/09/2012 12:00:00 AM	ADDRESS	34.03284	-118.23852	Plan check for energy and exit signs. 2106sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2720	14041-10000-14705	660 S SAN PEDRO ST	90021	14	126A213    93	5147026001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	PIN	34.04070198	-118.24613287	T24, REPLACE HID LIGHT FIXTURES WITH NEW FLORESCENT LIGHT FIXTURES, TOTAL AREA 8640 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2721	18041-10000-08918	3507 S GRAMERCY PL	90018	8	120B189   930	5042030019	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.02428	-118.31395	PC for new rooftop solar for 4.2kW rooftop solar in SFD. Installing 15 modules (4.5kW) and ABB central inverter. See comments.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2722	16041-10000-32795	9657 N PINE ORCHARD ST	91331	7	201B161   969	2624013***	(T)(Q)RD5-1-CUGU, RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.24522	-118.40976	PV SYSTEM ROOF MOUNTED 2 CENTRAL INVERTERS USING 23 MODULES IN TOTAL. TOTAL RATING 6.6 KW AC	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2723	18041-10000-22220	11668 W SHERMAN WAY 2nd Flr	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Apartment			06/14/2018 12:00:00 AM			PC Info Complete	06/22/2018 12:00:00 AM	ADDRESS	34.20103	-118.38683	PC FOR Interior T.I FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 268 SQ.FT. ON 2ND FLOOR (Muscle Biopsy Room) B#18016-10000-19005	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2724	15041-10001-19731	380 WORLD WAY LV.3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to approved set - lighting system changes.  Permit pulled under this number. Master number is PC only.(((TOM BRADLEY INTL. IN-TRANSIT CORRIDOR REMODEL. PC FOR ENERGY ONLY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2725	16041-10000-32614	1318 S BERENDO ST	90006	1	129B197  1190	5075003004	[Q]R4-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.0466	-118.29343	PC FOR TITLE 24 ONLY.SCOPE INCLUDES NEW LIGHTING FOR OUTDOOR PARKING. SPACE TOTAL AREA  4950 SQ0FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2726	16041-20001-43762	14725 W ARMINTA ST	91402	6	189B149   476	2210021012	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Approved	01/11/2017 12:00:00 AM	ADDRESS	34.21367	-118.45391	01/11/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan and there has been the addition of outdoor lighting. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for energy only. TI to office building. New lighting (incl. emergency) and receptacles. 9,727sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2727	13041-20000-33968	7404 N WISCASSET DR	91307	12	186B085   154	2017036012	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	PIN	34.20626576	-118.65928574	PV1 GROUND MOUNTED SYSTEM. TOTAL SYSTEM SIZE 10KWAC. 40 MODULES AND 2 INVERTERS.APPLICANT TO HAVE A SEPARATE BUILDING PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2728	17041-20000-39064	21729 W VANOWEN ST	91303	3	183B105   926	2138006034	(WC)RIVER-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.19394	-118.60246	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a change of use from retail to dental office. Total lighting area = 4,200 sq. ft.Note: Building application has been generated under 17016-20000-31935	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2729	14041-20000-25863	474 E 41ST ST	90011	9	115-5A207 477	5113005011	R2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.00908	-118.26661	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2730	11041-20000-02796	444 S FLOWER ST 38th floor	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	03/14/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	energy plan check 38th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2731	14041-10000-10391	4749 E NOB HILL DR	90065	1	153A221   205	5475015008	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.11365	-118.2148	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2732	11041-20000-06879	5461 N LOUISE AVE RUBB-RR BLDG	91316	5	174B133   709	2257011006	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM			PC Info Complete	04/06/2011 12:00:00 AM	ADDRESS	34.17055	-118.50999	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR EXISTING BASKETBALL COURT/RESTROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2733	14041-10000-04666	4212 E WILLIMET AVE	90039	13	159B205   355	5594002014	MR1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.1324	-118.26523	PLANCHECK FOR T24 ENERGY FOR A (N) STORAGE BUILDING 1994 SQ, EMERGENCY LIGHTING. <400 AMPS.BUILDING P# 14010-10000-00376	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2734	16041-10000-20290	5822 S 3RD AVE	90043	8	108B189  1483	4005022006	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	33.98841	-118.32045	PV1, rooftop solar instllation 2.5 kW AC system.   (10) SW275,   (10) M250 Enphase	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2735	16041-10000-36917	1200 W WILSHIRE BLVD 5th floor	90017	1	130-5A207  69	5143019022	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM			Corrections Issued	10/18/2016 12:00:00 AM	ADDRESS	34.05294	-118.26512	PC OF TITLE 24. ENERGY ONLY. .HIGH RISE BLD 5TH FLOOR.SCOPE OF WORK INCLUDES NEW LIGHTING AND NEW RECEPTACELS.TOTAL AFFECTED AREA OF 15951 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2736	13041-10000-21253	16817 W VENTURA BLVD 7600	91436	5	168B133   138	2259010005	C2-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.15903	-118.49931	TITLE-24 PLAN CHECK FOR INDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2737	17041-10001-26084	721 E BROOKS AVE	90291	11	111B145  1266	4239007006	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	33.9972	-118.46561	EXPEDITED FEE FOR PERMIT BELOW 17041-10000-26084PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE (3.6KVA) WITH BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF 1 INVERTER (ABB PVI 3.6) WITH 15 MODULES (SOLARCITY).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2738	14041-10002-23521	2645 S LA CIENEGA AVE	90034	10	123B173   670	5065007006	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.0335	-118.3785	Expedite per customer requestPV2 43.095 KW roof-mounted system including 169 hanwha solar modules and one Fronius CL 33.3KW  inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2739	16041-10003-16012	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			03/09/2018 12:00:00 AM			PC Approved	03/09/2018 12:00:00 AM	PIN	34.04222127	-118.45848597	Change to approved set by modifying light fixture and control on the floor plan. All changes under delta-4 only.(((NEW MIXED USED APARTMENT BUILDING 147 UNIT 5 STORIE .PLAN CHECK FOR POWER AND ENERGY. 12 TYPICAL UNITS, 6 LOFTS AND 3 LIVEWORK UNITS. WITH TOTAL AREA OF 1927884 SQFT. NOTE FIRE ALARM VARIANCE IS FILLED TOGETHER. BUILDING APPLICATION NUMBER 14041-10000-03747.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2740	11041-10001-04590	10201 W PICO BLVD BLDG#101	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	PIN	34.05182951	-118.41257696	REVISIONS TO PHASE 3 MODIFICATIONS- REVISED LIGHTING SYSTEM/UPDATED TITLE 24 COMPLIANCE FORMS; AND ADDED NEW CIRCUITS FOR ROOMS ADDED;NOTE THAT PHASE 3 PLANS HAVE BEEN PERMITTED BUT NO INSPECTION HAS BEEN DONE AT THIS TIMETi in the FOX technical operation center. This  Phase  3 of the project (total of 5). EPC is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2741	16041-10000-34743	1001 S OLIVE ST	90015	14	127-5A209 230	5139009016	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.04228	-118.25988	PC FOR POWER AND ENERGY. FIRST TIME TENANT. COFFEE SHOP. TOTAL AREA 1700 SQ ST. ADDITION OF LOAD LESS 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2742	18041-10000-04583	12335 W VENICE BLVD	90066	11	111B153    61	4248032003	[Q]C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.00402	-118.43332	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR AND EXTERIOR WORK . TOTAL AFFECTED AREA 12721 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2743	19041-10000-32673	1231 N SPRING ST		1	135A215   169	5414014001	C2-2, [Q]C2-2	Central	Central City North	Historic Cultural North		2060.10	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	PIN	34.06461924	-118.23604048	PC for a new fire alarm system in a exisitng multi-occupancy office, scope of work is one fire alarm panel, and 70 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2744	18041-30000-14086	1237 S HOLT AVE	90035	5	132B173  1132	4332023054	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.05466	-118.37863	Plan check for a fire alarm for a 5-story, 34-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (125) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2745	12041-10000-04988	7928 W HOLLYWOOD BLVD 1-79	90046	5	147B177   425	5551016003	R3-1XL	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Apartment			03/05/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.10106	-118.36259	New 79 units residential appartment BLDG. EPC is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2746	14041-20000-00745	8853 N MOORCROFT AVE	91304	12	195B101   132	2004024020	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Expired	02/18/2016 12:00:00 AM	ADDRESS	34.23165	-118.61103	"PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 11.0KWAC. ""ZERO FEES DUE TO 2012 SENATE BILL 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2747	15041-20001-14640	13330 W HUBBARD ST	91342	7	225B157   503	2512019029	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM			PC Approved	06/02/2015 12:00:00 AM	ADDRESS	34.31336	-118.42336	Expedite per applicant request************Plan check for PV 1 roof mounted 5.4kWac system and 24 modules and 24 micro-inverter(Enphase)******************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2748	14041-20001-06556	10750 N MELVIN AVE	91326	12	207B117   128	2708006045	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM	ADDRESS	34.26612	-118.55989	(((Expedite fees)))PV1 ROOFMOUNTED SYSTEM. TOTAL SYSTEM SIZE 11.4KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2749	13041-10000-12670	14220 W VALLEY VISTA BLVD	91423	4	165B153  1026	2274018001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	PIN	34.14460292	-118.44312058	PV1 24.25KW ROOFMOUNT SOLAREDGE OPTIMIZERS NONSTANDARD PLAN. {inverters se6000A-US( 3x) se5000a-us (1x) } .{ trina modules TSM-245PC05 (99x)}. 2 story house. New main panel permit number is 13041-10000-20010.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2750	14041-20001-10119	12810 N MEADOWLARK AVE	91344	12	222B133   451	2602009003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.30331	-118.50857	(((expedite fees)))pv1 single family dwelling. total; system size 9KW ac using multiple inverters. transformerless. nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2751	16041-30000-03763	11823 W DARLINGTON AVE 1-10	90049	11	129B145   343	4265017034	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.05085	-118.46669	Installation of fire alarm in new 14 unit apartment building.  Total system size = 77 Devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2752	18041-20001-14664	1827 S MIDVALE AVE	90025	5	129B153   690	4323006027	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			06/19/2019 12:00:00 AM			PC Approved	07/19/2019 12:00:00 AM	ADDRESS	34.04855	-118.43747	Plan check only. Recheck of lost set of plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2753	18041-10000-48391	523 W 6TH ST STE 212	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Issued	01/14/2019 12:00:00 AM	ADDRESS	34.04864	-118.25484	TI TO EXISTING OFFICE ON THE 2ND FLOOR IN SUITE # 212. (5,065 SF).  INSTALL NEW LIGHTS.T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-36235	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2754	17041-20000-12071	20356 W ABERDEEN LANE	91326	12	213B109   777	2701094022	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.28302	-118.57854	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD ACM PLAN. SYSTEM SIZE: 4.8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2755	15041-10000-10685	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL-RIO, [Q]PF-1XL-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.18088	-118.48309	replace  two existing 20 hp pump to new same hp one in pump station. class 1 division 1 of classified area(note 12)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2756	17041-20003-27543	11631 W VICTORY BLVD	91606	2	180B169  1019	2335012019	C1-1VL, RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM			PC Approved	07/23/2019 12:00:00 AM	ADDRESS	34.18685	-118.38564	"07-23-2019 Changes to an approved set of plan, changes include outdoor lighting to feed with 277 Volt, all lighting to remain in place. All Changes apply to delta ""D"". Plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2757	18041-20000-32909	10146 W BAYWOOD CT	90077	5	153B153    54	4382029***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.11783	-118.44128	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6.65 kWdc/7.6 kWac and consists of (1) inverter, (19) modules, (1) load center, (1) auto-transformer, and (1) LG Chem battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2758	18041-20000-28098	7001 S SEPULVEDA BLVD	90045	1	102B165   213	4110001015	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1994.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	33.97667	-118.39439	PV1.  Install roof mounted grid tied PV system sized 15.2kW AC interconnected with MSP.  (54) modules with string inverter.$0 per State Senate Bill SB 1222 as amended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2759	10041-10002-10033	942 S TOWNE AVE	90021	14	124-5A211 251	5132003022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM			PC Approved	02/28/2011 12:00:00 AM	ADDRESS	34.03442	-118.24926	Change the priviously approved plan. Change the type of lights. EPC is for change. ((((((((((((Change of use from ware house to retail. Plan check for power and energy.)))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2760	16041-10000-02414	10105 N COMMERCE AVE	91042	2	204B197  1062	2565013047	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Info Complete	01/26/2016 12:00:00 AM	ADDRESS	34.25251	-118.28882	T24 ONLY. PC FOR ENERGY. TOTAL AREA (INDOOR LIGHTING) 6694 SQ FT.  TITLE 24 FORMS IS UNDER 2008 NEC ENERGY CODE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2761	15041-10000-13062	12839 N NEON WAY	91344	12	222B129   162	2601043022	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.30361	-118.51757	PV1 ROOF MOUNTED, 30 MODULES WITH 1 INVERTER. TOTAL SIZE 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2762	15041-10000-10376	837 E TRACTION AVE	90013	14	127-5A215  81	5163015005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.04476	-118.2347	INSTALLING 35 EA NEW FC UNITS AND 8 EA MCU IN 35 UNITS APT BLDGNEW FEEDER AND PANEL BOARD TO SUPPLY AC UNITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2763	17041-20000-31878	16620 W STAGG ST	91406	6	189B137   108	2205009079	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.21302	-118.49616	"""0$ permit fees due to senate bill 1222""Plan check for solar pv system, roof-mounted on commercial building.336kW ungrounded system [(5) 60kW + (1) 36kW inverters](1,311) 340W pv modules. Line side tap.BUILDING PERMIT # 17016-20000-29565"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2764	18041-20000-41427	5451 N WILBUR AVE	91356	3	174B121   626	2161002006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	04/07/2021 12:00:00 AM	ADDRESS	34.17018	-118.54487	Plan check for PV roof mounted system, system size: 11.55KW DC, 10.0KW AC with 35 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2765	19041-10000-29373	304 S BROADWAY #410	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR T24 ONLY, SCOPE OF WORK IS A TI IN A OFFICE SUITE, SUITE 410 OF A HIGHRISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES, AND CONTROLS, TOTAL AFFECTED AREA IS 1530 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2766	12041-10000-26829	4800 S VERMONT AVE	90037	9	111B197   825	5018012028	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	33.99939	-118.29135	POWER PLAN CHECK AND TITLE 24 FOR NEW COIN LAUNDRY. (6000 SF OUTDOOR LIGHTING PER APPLICANT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2767	18041-10000-22639	10416 N ELDORA AVE	91040	7	204B189   167	2560008013	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	PIN	34.25840355	-118.31460921	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.5 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2768	14041-10000-20183	6600 N TOPANGA CANYON BLVD #11	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	permit to be pulled at EPC counter only. Plan check for energy only 2013T24 standards. Westfield Topanga - tenant space #11 - Level 1. emergency lighting installed.  BLDG#14016.10.14196	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2769	18041-10000-36250	2301 S CLOVERDALE AVE 1-5	90016	10	123B177  1957	5063008066	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			09/21/2018 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.03671	-118.35592	Full plan check for a new 4-story  5-UNIT APARTMENT BUILDING WITH ATTACHED PARKING GARAGE ON GRADE. Scope includes (1) 600-Amp service and (6) panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2770	15041-10000-19521	401 S GRAND VIEW ST	90057	8	111B189   926	5015033012	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Apartment			06/22/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.06322	-118.27542	NEW FIRE ALARM SYSTEM 120 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2771	17041-20000-45939	10201 W PICO BLVD BLDG 54	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Issued	02/05/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	TI to an existing office building.  Plan check for energy - 4108 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2772	15041-10000-00568	12492 W OSPREY LANE Bldg4-1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Expired	07/17/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	NEW FIRE ALARM SYSTEM WITH 41 DEVICES AND 1 FIRE ALARM CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2773	13041-10000-31521	727 S CROCKER ST	90021	14	126A213   309	5146033047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.03959	-118.24673	NEW LIGHTING AND CIRCUITS  IN A REMODELED WAREHOUSE/OFFICE BUILDINGPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2774	17041-20001-25412	1396 W EAGLE VISTA DR	90041	14	162A229    35	5691012036	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	PIN	34.14008288	-118.19424559	EXPEDITED PER APPLICANTS REQUEST.PV2. APT. ROOMFOUNTED INSTALLATION . SYSTEM SIZE: 7.4 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2775	13041-10001-28444	1036 S NORTON AVE	90019	10	129B189   219	5081010007	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Apartment			10/27/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Expired	12/27/2016 12:00:00 AM	ADDRESS	34.05283	-118.32105	changes to approved set, changes includes dropping main service 3-phase 4-wires from 1600-Amp to 1200-Amp and 120/240 to 120/208 volts. (((pc for power and energy. NEW 3-STORY TYPE III-A 22 UNITS APARTMENT OVER ONE LEVEL TYPE I-A PARKING GARAGE (10010-10000-02356). Methane Buffer Zone. fire alarm variance filed on 10/11/2013 and paid-mt)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2776	07041-10001-09832	1526 N EDGEMONT ST	90027	13	147B197   513	5543010016	RD1.5-1XL	Central	Hollywood	Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Info Complete	03/09/2011 12:00:00 AM	ADDRESS	34.09898	-118.29599	Refeed  existing building from a different switchboard in the facility.  Normal and emergency supplies. Provide power to two new motors. (((((((((((((((((((((((((((((((   Remove a 1200 amps frame, trip to 1200 amps frame with 800 amps trip. and 30 days demand reading.  3-9-11)))))))))))))))))))))))))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2777	15041-20000-16098	4632 W SANTA MONICA BLVD	90029	13	144B197   734	5539003014	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			Reviewed by Supervisor	06/19/2015 12:00:00 AM	ADDRESS	34.09073	-118.29041	Plan check for power and lighting. Project site is an existing commercial building. Project scope is a tenant improvement. Service is existing. Work includes the installation of (6) new panel boards and associated loads. Total lighting area = 24,212 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2778	19041-20000-48540	10226 N ENCINO AVE	91325	12	204B129   216	2734026003	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	07/07/2020 12:00:00 AM	PIN	34.25637351	-118.51512693	PV1 PLAN CHECK FOR NEW PV. SYSTEM SIZE IS 4.03 KW DC/3.8 KW AC. SCOPE OF WORK CONSISTS OF (13) PV MODULES AND A 3.8 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2779	14041-10000-33281	800 W OLYMPIC BLVD #A120	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.04484	-118.26453	TI for remodeling of restaurant - scope of work is lighting only per applicant.  Plan check for energy.  Emergency lighting existing to remain per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2780	14041-10000-10808	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM			PC Approved	04/24/2014 12:00:00 AM	ADDRESS	34.17705	-118.6144	permit to be pulled at EPC counter only. Plan check for energy only. OUTDOOR LIGHTING (8 lights next to play area and parking lot) FOR WOODLAND HILLS RECREATION CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2781	16041-30000-16375	5177 N BRIAN LANE	91436	5	171B137   116	2260017037	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.16447	-118.48772	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2782	15041-10000-10506	521 S OLIVE ST	90013	14	129A211     2	5149030003	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.04903	-118.25355	Energy plan check for a retail T.I (tea shop) ; total area is 1485-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2783	18041-20000-30824	1423 S ABBOT KINNEY BLVD	90291	11	108B145  1348	4241036006	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM			PC Info Complete	08/14/2018 12:00:00 AM	ADDRESS	33.99059	-118.46514	Plan check for Title 24 Energy only in existing retail space T.I.  Total area: 773 sq ft. B#18016-100000-25999	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2784	15041-10000-10595	10176 N RESEDA BLVD	91324	12	204B125   232	2731018018	P-1VL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM			PC Info Complete	04/22/2015 12:00:00 AM	ADDRESS	34.25589	-118.53588	TI TO AN EXISTING COMMERCIAL BUILDING, RESTAURANT. NEW LIGHTING AND NEW CONTROLS USING EXISTING PANELS. PC FOR ENERGY AND EMERGENCY LIGHTING ONLY. TOTAL SQ. FT. 1715.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2785	16041-10001-38467	20445 W ESMERELDA LANE	91326	12	216B109   263	2701082078	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.29108	-118.5797	01/18/17Changes to an approved set of plans. changes include removing 10 modules from roof-layout and single line diagram, replacing module type from Canadian solar CS6K-275M to LG 285S1C-G4, and using an AC combiner box instead of a panel load center. All changes are clouded under delta R1.(39)Modules-LG 285S1C-G4(39)microinverters-Enphase M250-60-2LL-S22 Note: permit is paid under PCIS#16041-10000-38467PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.475KWdc / 11.76KWac.(49)MODULES-CANADIAN SOLAR CS6K-275M(49)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2786	18041-10000-36102	11840 W FOOTHILL BLVD Unit #C	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.27347	-118.39434	NEW RESTAURANT, FIRST TIME TENANT IN UNIT #C.PLAN CHECK FOR POWER AND ENERGY.BLDG PERMIT: 18016-10000-10247	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2787	16041-10000-07296	1367 N ALTA VISTA BLVD	90046	4	147B181   990	5548020039	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.09588	-118.34738	Full PC to new 12 unit apartment (4 story buiiding). All new equipment. Main service : 800 Amps. Total sq ft = 16500.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2788	09041-10001-14219	13515 S FIGUEROA ST	90248	15	078B201   102	6132005009	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM			PC Approved	02/02/2010 12:00:00 AM	PIN	33.90872221	-118.28341949	PC ONLY.Delta 2 modifications only.  See the original plan for complete electrical installation.  to the plan26,150  SF, Tenant Improvement to an existing 38, 776 commercial bldg, (N) sanctuary, (N) classrooms,  (N) Activity room.  The site is indicated as  in a Methane Zone in ZIMAS.  Conduit seals required where exiting ground, see conduit to  monument sign j-box.  Sign is future.  Permit to be issued on original submittal.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2789	19041-10001-16912	2429 N NOTTINGHAM AVE	90027	4	153B193   290	5588003017	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM			PC Approved	05/24/2019 12:00:00 AM	ADDRESS	34.11304	-118.3017	expedited per customer request.PV1. SYSTEM SIZE OF 11.2575 KWDC AND 9.47 KWAC WITH (474) TESLA MODULES, (2) 7.6  AND 3.8 KW TL INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2790	13041-10000-34005	6093 1/2 W SUNSET BLVD	90028	13	147A189    50	5545008400	[Q]C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			Verifications in Progress	12/24/2013 12:00:00 AM	ADDRESS	34.0982	-118.32191	TI for a 1295 sq. ft.  Papa John's Pizza restaurant.  No change of use.  Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2791	14041-10000-34825	14635 W PARTHENIA ST	91402	6	195B149   595	2653002042	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.22795	-118.45121	ENERGY PLAN CHECK FOR REMOVING HID LIGHT FIXTURE AND REPLACING WITH LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2792	16041-10000-26292	125 W 80TH ST	90003	9	099B201   652	6031024017	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	33.96703	-118.27481	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(13)MODULES- KYOCERA #KU265ZPA(1)INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2793	16041-20000-41007	10257 ANGEL LANE	91331	7	204B165   438	2537004048	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25697496	-118.40484938	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP.3kW ungrounded system. (12) 305W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2794	10041-20000-14858	22420 W DEL VALLE ST	91364	3	171B101   174	2040034022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1372.01	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM			PC Info Complete	07/30/2010 12:00:00 AM	ADDRESS	34.16821	-118.61507	energy plan check retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2795	19041-20000-17934	420 W MANCHESTER AVE	90003	11	096B153  1057	4116024008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	PIN	33.95570926	-118.44329696	Plan check for a PV1 roof-mounted PV system. System size is 3.3 kWdc/.994 kWac-CEC and consists of (10) modules, (10) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2796	12041-10000-01770	8810 N TAMPA AVE	91324	12	195B121   511	2784003069	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.01, 1153.02	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	ADDRESS	34.23097	-118.55317	Plan check for T24 Energy/Emergency lighting- in a COSTCO Store, replace existing tire center lightingfixtures; add new lcp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2797	16041-10000-40669	4900 N SERRANIA AVE	91364	3	169-5A109  71	2166046026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.15898	-118.58816	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 103835 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2798	17041-10001-30036	1241 N ROSCOMARE ROAD	90077	5	144B145   107	4377019011	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.09227	-118.46266	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2799	13041-10000-32351	1026 S BROADWAY BLDG A	90015	14	126A209   140	5139014006	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Closed	03/04/2019 12:00:00 AM	ADDRESS	34.04029	-118.25788	PLAN CHECK FOR POWER AND ENERGY. NEW BUILDING LOCATED IN METHANE ZONE.5-story Type III-A, 236 UNIT apartment building over 2-story Type I-A Retail, Common area, parking and  3-basement LEVELS OF  parking garage	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2800	14041-10000-15414	2652 S ORCHARD AVE	90007	9	123B197  1171	5055026025	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			06/10/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.03128	-118.28731	PV1, Install 2.04 KW DC roof-mounted solar array on a two-story house, interconnect with main service panel. Transformerless inverter. With optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2801	10041-10001-00889	1150 N DOHENY DR	90069	4	144B169   407	5560031007	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2010 12:00:00 AM			PC Approved	09/29/2010 12:00:00 AM	ADDRESS	34.09188	-118.39029	Supplemental changes from previously approved plans.  Changes include loads.  All changes indicate by DELTA 10 as shown on plans.  Plan check for power only.*****Change from previously approved plans )08041-20000-24204).  Changes include feeders, lighting, and panel loads.  All changes indicate by DELTA 8 and DELTA 9 as shown on plans. ******	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2802	17041-10000-14438	3480 N CAHUENGA BLVD	90068	4	159B177   238	2425001073	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.13295	-118.35549	PC for energy only, Outdoor/indoor Title-24. Removing HID fixtures and replacing them with new LED ones. Area: 86,850 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2803	18041-10001-31315	1200 N AVENUE 54	90042	14	154-5A227  57	5478023031	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	09/17/2018 12:00:00 AM	ADDRESS	34.11931	-118.19905	EXPEDITED FEEPLAN CHECK FOR 3.8KVA ROOF MOUNTED PV SYSTEM CONSISTING OF CENTRAL INVERTER(SE3800H-US) WITH 12 MODULES USING (P400) OPTIMIZERS APPLICATION TIED IN WITH 18041-10000-31301 SAME PROPERTY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2804	18041-20000-40332	837 S THAYER AVE	90024	5	135B153   267	4360017037	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.06607	-118.43483	PV1.  Install 10.552 kW AC-CEC roof mounted grid tied PV system.  (34) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2805	14041-20000-24777	7000 S HOOVER ST Unit #1	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #1.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2806	15041-10000-07589	123 S FIGUEROA ST	90012	14	132A211     6	5151001026	C2-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.05725	-118.25278	plan check for energy only. permit to be pulled at EPC counter only. PROPOSED CREPE DE PARIS SHOP ( 914.8 SQ. FT.) see 14016 10000 25280.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2807	10041-10000-19260	700 W WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	12/07/2010 12:00:00 AM	PIN	33.94153561	-118.3984113	REPLACEMENT OF 1 ESCALATORS AND  1 ELEVATOR  AT TERMINAL 7 LAWA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2808	16041-20001-31971	5200 S CENTRAL AVE	90011	9	108B209    95	5104003034	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			PC Approved	05/11/2018 12:00:00 AM	ADDRESS	33.99574	-118.25623	Revisions to approved set of plans.  Change of inverter type to SolarEdge system.  Total rated AC max output unchanged.  (((Plan check for the ground-mounted portion of a PV2 roof-mounted & ground-mounted PV system. PV system is part of the LADWP feed in tariff (FIT) program. Ground-mounted portion is 267 kWac and consists of (6) 36 kWac inverters, (1) 28 kWac inverter, (1) 23 kWac inverter,  (954) modules, and (3) load centers. Total system size is 323 kWac.Note: Roof-mounted portion of the PV2 PV system can be found under application number 16041-20000-31964)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2809	19041-10000-53128	686 N SPRING ST	90012	1	133-5A215 183	5408013017	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	07/31/2020 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	PIN	34.05955004	-118.23772617	T-24 PLAN CHECK FOR A TI TO EXISTING OFFICE SPACE. NO CHANGE OF USE. TOTAL AFFECTED AREA IS 2581 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2810	12041-10000-01257	973-977 E ELKHART PL BLDG 45	90291	11	111B145   756	4243003035	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/19/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	33.99997	-118.46096	removing existing wall heaters from 28 units and replacing with split system heat pump. also addition of site lighting to existing house panel, revise existing lighting in the kitchens.  <<Multiple addresses in this building 934 - 936 Lake St & 1002 - 1012 Frederick St & 973 - 977 E. Elkheart >>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2811	10041-10000-24446	1150 1/2 S ELM DR	90035	5	132A167   197	4330032016	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM			PC Approved	12/08/2010 12:00:00 AM	ADDRESS	34.05567	-118.39477	TENANT IMPROVEMENT IN A RETAIL STORE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2812	17041-20001-08121	17742 W RAYEN ST	91325	12	195B129   252	2768012007	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.23185	-118.52159	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 150A. 15.2kW ungrounded system [7.6*2]. (63) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2813	19041-70000-38863	2201 E TROJAN WAY	90033	14	135A225   143	5202001011	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.06467	-118.2022	LOW-VOLTAGE WORK	N	N	Express Permit	06/10/2024 12:00:00 AM
2814	14041-10000-13428	14400 W FRIAR ST	91401	6	178-5A151  53	2240002014	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			05/20/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.18554	-118.44668	Plan check for power and energy, New 4 story apartment building, first story is parking, 29 units. Total area 8386+ 1193(indoor+ outdoor) sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2815	16041-10001-24464	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	ADDRESS	34.09818	-118.35187	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2 AND DELTA 4. CHANGES INCLUDE ADDING/REMOVING LIGHTING FIXTURES, REVISING LIGHTING FLOOR PLANS, REVISING SINGLE LINE DIAGRAM, AND REVISING TITLE 24 CALCULATIONS. PLAN CHECK ONLY.  NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-24464	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2816	17041-10000-15287	9500 N TOPANGA CANYON BLVD	91311	12	201B101   596	2746018008	(Q)MR1-1, [T][Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24312	-118.60633	PC for energy only, Outdoor Title 24. Removing HID fixtures and replacing them with new LED fixtures. Total area: 59,400 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2817	13041-10001-23601	1229 N WESTMORELAND AVE	90029	13	144B197   141	5542020017	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Apartment			08/29/2013 12:00:00 AM			PC Approved	12/04/2013 12:00:00 AM	ADDRESS	34.09429	-118.28793	Expedited plan check for solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2818	19041-20000-22207	22135 W ROSCOE BLVD LOT #28	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 28.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2819	14041-20001-31692	15558 W PLUMMER ST	91343	7	198B145    49	2656015017	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM			PC Approved	12/19/2014 12:00:00 AM	ADDRESS	34.24262	-118.47164	expedite fees10kw ac PV system. using 28 modules. nonstandard plan. derate main breaker	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2820	14041-20001-02600	22853 W ENADIA WAY	91307	12	183B097   149	2026002028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.2002	-118.62518	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2821	11041-20000-16357	9333 N OSO AVE	91311	12	198B113   116	2748022081	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.24018	-118.57555	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING OFFICE AND WAREHOUSE AREA. PERMIT FOR NEW 120V, 277V CKTS, AND NEW FIXTURES ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2822	12041-20000-15394	2035 N HILLHURST AVE	90027	4	150B197   362	5590007036	C4-1D	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.10865	-118.28759	T.I. to existing space inside Albertsons store at the financial transaction area.  Install new general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2823	13041-10000-30078	3292 S WOODBINE ST	90064	5	123B161   770	4316021011	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.03153	-118.406	PV1, Install 7.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 29 modules Trina Solar TSM-250PA05.18.n	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2824	16041-20000-40148	11155 W HUSTON ST	91601	2	168B173   130	2353017009	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	ADDRESS	34.15988	-118.37347	New 4-story 15-unit apartment building.  800A 208Y/120V service.  Plan check for power and enegy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2825	16041-10001-05995	1751 E BAY ST	90021	14	123A215   239	5166035***	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM			PC Approved	04/12/2016 12:00:00 AM	ADDRESS	34.03159	-118.23577	EXPEDITE FEESPV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 1060KW DC / 900KW AC. TOTAL OF 3366 MODULES IN TOTAL. 15 INVERTERS. CONNECTED TO EXISTING SERVICE. NET METER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2826	17041-10001-09148	245 N SOTO ST	90033	14	129A223   353	5183004028	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.04632	-118.20835	PC FOR REVISION TO APPROVED SET FOR A RESTAURANT TI (MCDONALADS)TO REFLECT CHANGES TO LIGHTING FIXTURES SCHEDULE. THIS IS PLAN CHECK ONLY!!!Total area: 2376 sq ft.permit under 17041-10000-0914817041-10000-19291	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2827	10041-10000-25530	4160 N EAGLE ROCK BLVD	90065	14	156A219   159	5472001031	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.00	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	12/27/2010 12:00:00 AM		Permit Finaled	09/21/2011 12:00:00 AM	ADDRESS	34.12161	-118.22511	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2828	10041-10000-04555	2122 1/2 W COLORADO BLVD	90041	14	162A223   128	5686003013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	03/15/2010 12:00:00 AM		Permit Finaled	03/16/2010 12:00:00 AM	ADDRESS	34.13894	-118.21282	Install new general lighting for a restuarant.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2829	17041-10001-19894	13058 W BLOOMFIELD ST	91604	2	165B161   480	2375013033	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	PIN	34.14900274	-118.41794951	SUPPLEMENTAL TO PERMIT#: 17041-10000-19894 PANEL UPGERADE FROM 200 AMP TO 200/225 AMP BREAKER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2830	15041-30000-41274	6310 W SAN VICENTE BLVD Suite 240	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.06084	-118.36757	Title 24 plan check only.  Total area = 3,450 sq. ft.    T.I. to create gym area in part of second floor of existing commercial low rise building.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2831	17041-20003-07909	19601 S HAMILTON AVE	90502	15	057B197    81	7351033023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM			PC Approved	02/06/2018 12:00:00 AM	ADDRESS	33.85319	-118.28624	02/06/2018 Changes to an approved set of plans. Changes include revising electrical equipment ratings to accomodate revised loads.01/30/2018 Changes to an approved set of plans. Changes include the installation of a new transformer, new distribution equipment, and provisions for the installation of 3D printing equipment. There has been a change of engineer.*****Previous Work Description*****Couduit only permit*****Previous Work Description*****Plan check for power and energy in hazadous location for 3 dimensional printing aluminum powder inside the printing machine. Total area: 4,620 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2832	16041-10000-44942	3545 W CASITAS AVE LOT 8	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12077	-118.25706	Plan check for Power 11 buildings SFD live work  3 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 8 of 11Note: Master Application Lot 8 type A1,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2833	19041-10000-46799	1429 W 259TH ST	90710	15	033B193   128	7411007065	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	33.78829	-118.30229	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2834	12041-10000-04050	801 W 34TH ST	90089	9	120A201    20	5039003***	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM			PC Approved	02/23/2012 12:00:00 AM	PIN	34.02383917	-118.28572873	ADDITION OF 999 SQUARE FOOT BASEMENT FOR OFFICES; TENANT IMPROVEMENT FOR USC, ELECTRICAL PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTS. (Joint Educational Project BLDG)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2835	18041-10000-19220	15089 W ROXFORD ST	91342	7	228B145   267	2502027020	RS-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	04/25/2019 12:00:00 AM		Issued	04/25/2019 12:00:00 AM	ADDRESS	34.3202	-118.46208	FULL PC FOR POWER AND ENERGY FOR A NEW  ONE-STORY BIBLE STUDY/FELLOWSHIP BUILDING W/ ATTACHED COVERED PATIO. A-OCCUPANT LOAD > 100. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4665 SQ. FT. B#17010-10000-03761	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2836	17041-20003-29102	15253 W GOLDEN CT	91342	7	219B145   688	2611041026	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Issued	01/30/2018 12:00:00 AM	ADDRESS	34.29481	-118.46533	01/30/2018 Changes to an approved set of plans. There has been an addition of (1) PV module to the PV system. Inverter size has remained the same. 11/21/2017 CHANGES TO APPROVED SET. RELOCATING THE ENERGY STORAGE SYSTEM*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6 kWac and consists of (1) inverter, (19) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2837	07041-10001-19961	5633 W CARLTON WAY	90028	13	148-5A193 220	5544026016	R4-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			01/15/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	08/22/2011 12:00:00 AM	ADDRESS	34.10062	-118.31267	New 17 unit apartment complex.  Permit is for new service, new panels, new circuits, new equipment, and new lighting fixtures.  P/C is for Power and Energy (T-24).  Variance for Fire Alarm submitted.9(((((((((((((((((((((((((( Change of service entrance. 1-15-10)))))))))))))))))))))))))))))))))))))))))))))))))))Electrical permit fees are based on 07041-30000-19961	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2838	18041-20000-02891	7751 W MELROSE AVE	90046	5	141B177   601	5527009026	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.08388	-118.35852	TITLE 24 PLAN CHECK ONLY FOR (TI AND CHANGE OF USE FROM RETAIL TO JUICE BAR. TOTAL AFFECTED AREA 490 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2839	15041-20003-38389	11821 W GWYNNE LANE	90077	5	153B141   106	4378037078	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM			PC Approved	04/14/2016 12:00:00 AM	ADDRESS	34.11581	-118.47468	4.14.2016 - Plan check for modifications to approved set. Combine all three strings to inverter. Show location of combiner box on roof plan and elevation diagram. Changes clouded.====04/01/2016 Changes to an approved set of plans. PV system now consists (1) 11.4 kWac inverter. Module count has remained the same. *****Previous Work Description*****PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel.(44) SOLARWORLD SW285 Modules(2) SMA America SB6000 TL Inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2840	15041-10001-33906	6414 W HAYES DR	90048	5	132B173   170	5088008003	R2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.06073	-118.36965	PV1, ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS. (35) MODULES AND MICROINVERTERS. ORIGINAL PERMIT FEES WERE PAID UNDER EXPRESS PERMIT #15041-70000-33906. NOTE: ZONING WAS DONE ON MASTER PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2841	17041-20001-11168	7930 N MASON AVE	91306	3	189B109   424	2107024029	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			Corrections Issued	07/25/2018 12:00:00 AM	ADDRESS	34.21478	-118.57959	PV2 Install roof mounted redesign from single phase to three phase PV system sized 30KW AC interconnected with msp.(120) modules (existing)(120) solar optimizers (existing)(3) 10KW solaredge inverters (new)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2842	16041-10001-33917	2226 N STRADELLA ROAD	90077	5	153B145   176	4377029005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2016 12:00:00 AM			PC Approved	11/17/2016 12:00:00 AM	ADDRESS	34.11332	-118.46236	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTA SYSTEM SIZE IS 56.24KWdc / 43.2KWac.(163)SUNPOWER SPR-X21-345(163)SOLAREDGE P400(3)INVERTERS-SOLAREDGE SE-14.4KUS(1)SUBPANEL 200A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2843	11041-20000-04334	6301 N OWENSMOUTH AVE 4TH FL	91367	3	177B105   123	2146029016	WC	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.18467	-118.60176	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT 4TH FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2844	17041-10001-15332	1601 N VINE ST 5TH-6TH FLRS	90028	13	148-5A187 301	5546009154	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM			PC Approved	08/07/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	REVISED PLANS TO INCLUDE NOTES AND INFORMATION ON CONTROLLED RECEPTACLES AS REQUIRED IN THE ENERGY STANDARDS(((((((FULL PLAN CHECK FOR A TENANT IMPROVEMENT IN THE 5TH AND 6TH FLOOR. ADDING NEW PANELS WITH A NEW ADDED LOAD GREATER THAN 400 AMPS. NEW LIGHTING. AREA: 26,824 SQFT.B#17016-10000-11792	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2845	18041-20001-20772	14235 W OXNARD ST	91401	6	177B153   828	2240025028	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	34.17954	-118.44357	revision for approved t-24 set. change is delta 2. removing lighting fixtures and updating t-24 calc. fixture A was removed.plan check onlyoriginal scope:2-STORY ADDITION FOR COMMERCIAL STORAGE BUILDING.  PLAN CHECK FOR LIGHTING ENERGY CONSERVATION REQUIREMENTS. TOTAL AFFECTED AREA 6025 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2846	18041-20000-47868	10154 N MOUNTAIR AVE B	91042	7	204B197   975	2558022060	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	01/30/2019 12:00:00 AM		Issued	01/30/2019 12:00:00 AM	ADDRESS	34.25383	-118.29306	TI with service upgrade to 600 amps. plan check fo power and enery.   (CHANGE OF USE FROM PARISH HALL TO CHILD CARE CENTER.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2847	17041-10000-05468	1900 N OLD RANCH ROAD	90049	11	135B133    40	4432010009	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.06911	-118.50434	Plan check for roof mounted PV System on SFD. System size: 24.3kW with 76 AC Modules connected to Existing 800A switch gear.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2848	17041-30000-03135	3741 S CRENSHAW BLVD	90016	10	117B185  1309	5046024026	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	02/24/2017 12:00:00 AM	ADDRESS	34.0187	-118.33556	Title 24 plan check.  Interior remodel of existing CVS store.  New lighting and receptacles in pharmacy area.  No patient care areas.  Total area = 1,003 sq. ft.Building permit #17016-40000-01282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2849	16041-20000-29874	1251 E 21ST ST	90011	9	120A211   149	5131009030	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	34.02331	-118.25271	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2850	15041-20000-20044	744 N OGDEN DR	90046	5	141B177   340	5527009003	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.08507	-118.35933	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, and (14) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2851	17041-30000-21047	10777 W SANTA MONICA BLVD	90025	5	129B153    23	4325030006	[Q]RD1.5-1-O, [Q]RD1.5-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.05147	-118.43332	Plan check for Title 24 only. Project site is an existing church. Project scope is outdoor lighting. Total lighting area = 138,962 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2852	19041-20000-29053	6830 N BALBOA BLVD	91406	6	183B133   921	2225023076	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.19445	-118.50092	Plan check for Title 24 energy only in existing space Tenant Improvement restroom and dining area only. Total area: 2260 sq ft. B#19016-20000-21849	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2853	15041-10000-14157	2231 S CARMELINA AVE	90064	11	123B149   977	4259026007	M1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.02996	-118.45539	NEW FIRE ALARM MONITORING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2854	12041-10000-29848	3435 W WILSHIRE BLVD SUITE 750	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00, 2123.04	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.06194	-118.29866	TENANT IMPROVEMENT WORK ON 15,175 SF OF THE TOTAL FLOOR AREA; MOVABLE PARTITIONS, NON-BEARING PARTITIONS, FIXTURES, FINISHES, PATCHING UP (E) CEILINGS, AND RELATED MILLWORKS. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2855	18041-20001-12297	1852 N MARCHEETA PL	90069	4	150B169  1092	5561008033	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM			PC Approved	05/09/2018 12:00:00 AM	ADDRESS	34.10612	-118.38882	Expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2856	18041-10000-03666	11846 N WOOD RANCH ROAD	91344	12	216B129   272	2601066001	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.28687	-118.52026	Permit fee is $0.00 due to Senate Bill 1222.Install New PV1 rooftop solar on (E) SFD, system size 15.2kW AC/ 18.85 kW DC. (2) 7.6 kW central inverters, (58) modules with (58) power optimizers, and (1) load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2857	17041-20000-41391	19315 W SATICOY ST A	91335	3	186B117  1034	2116014019	QC2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.20851	-118.55454	Change of use from retail to financial institution.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2858	17041-20000-29852	11611 W SAN VICENTE BLVD 520	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.0541	-118.46261	PLANCHECK FOR T24 ENERGY.  T.I. OF OFFICE SPACE UNIT # 520  ( 994 SF ) .building p #  17016-10000-17489	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2859	18041-20000-24560	6807 W APPERSON ST	91042	7	204B201   340	2569023024	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.25604	-118.27958	Plan check for battery back up system connected existing PV system. 2 Tesla PowerWall 13.5kWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2860	11041-20000-24956	9280 W NIGHTINGALE DR	90069	5	150B169  1384	5561007023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2011 12:00:00 AM	12/09/2011 12:00:00 AM		Permit Finaled	12/28/2011 12:00:00 AM	ADDRESS	34.10343	-118.39095	13.2 KW photovoltaic system on roof of single family residences.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2861	19041-10000-03378	9501 N CLYBOURN AVE	91352	6	198B173     7	2538012012	RE40-1-K-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1211.02	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM			Reviewed by Supervisor	03/05/2019 12:00:00 AM	ADDRESS	34.24188	-118.36898	PC FOR PV SYSTEM. 50 SUNMODULE SWA 295 MONO BLACK WITH 50 SOLAREEDGE P320 OPTIMIZER. 2 SOLAREDGE SE7600H-US INVERTER. 1 LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2862	16041-10001-33360	2324 E WHITTIER BLVD	90023	14	124-5A221 290	5189006061	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM			PC Approved	01/24/2017 12:00:00 AM	ADDRESS	34.03431	-118.21621	01/24/16Changes to an approved set of plans. Changes include relocating lighting fixtures, revising title 24 calculations, and relocating panel boards on the floor plans. Changes are made due to the relocation of a walk-in cooler. Note: permit is paid under PCIS#16041-10000-33360	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2863	19041-10000-44941	20209 W RINALDI ST	91326	12	210B113   291	2701100009	A1-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	09/30/2020 12:00:00 AM	ADDRESS	34.27509	-118.57388	0$ final fees per AB1414Plan check for a PV2 138 KW AC / 178 KW DC roofmounted system. Scope include 410-module, (3) inverter interconnecting throgh the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2864	15041-20000-28385	16908 W LASSEN ST	91343	12	201B133   168	2686027007	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.2501	-118.50057	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2865	14041-10000-19258	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	SERVER ROOM EQUIPMENT INSTALLATION IN A PARKING GARAGE 4 STORIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2866	18041-10000-45739	11933 W WILSHIRE BLVD	90025	11	129B145   944	4265014041	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.04639	-118.46493	PC FOR A NEW FIRE ALARM SYSTEM IN A COMMERCIAL 2 FLOORS BUILDING. SCOPE INCLUDES NEW FA CONTROL PANEL, ANNUNCIATOR AND 20 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2867	14041-20001-14823	4445 N NOBLE AVE	91403	4	166-5A147  24	2276006021	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			Corrections Issued	07/27/2015 12:00:00 AM	ADDRESS	34.15214	-118.46198	Plan check Title 24 only for existing class room. Total indoor area: 1,357 sqft[[[[[CHANGE OUT SWITCHES AND OUTLETS.]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2868	11041-10000-20629	1040-1044 S DOREEN PL BLDG 4	90291	11	111B149   684	4243002068	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99976	-118.45891	REPAIRS & HISTORICAL REHABILITATION  / TI OF 9 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2869	15041-10000-27516	7194 W FORMOSA FUSION CT	90046	5	141B181  1712	5525003037	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Expired	09/20/2017 12:00:00 AM	ADDRESS	34.08554	-118.3459	PV1 standard plan 1.72kW roof mounted system with (8) Enphase M-215 micoinverters and (8) SM-260PC8 modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2870	15041-20000-27756	5416 N ROZIE AVE	91367	3	174B089   683	2047014015	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.16895	-118.65137	PV1. Install roof mounted PV system sized 11 kW. Interconnected with main service panel. (48) KU265 Modules (1) PVI-6000 Inverter(1) PVI-5000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2871	15041-20000-34140	8748 N DEMPSEY AVE	91343	12	195B141   601	2672012046	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.22964	-118.47734	PV1, roof mounted 6.625 kW AC system. (25) modules: #KU2656ZPA, (1) inverter: PVI-5000-OUTD-US-Z-Astandard plan provided.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2872	11041-10000-03174	535 N LARCHMONT BLVD	90004	4	141B189   979	5523016026	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	34.08003	-118.3239	T.I.  2 NEW 200 AMP PANELS.  TITLE 24 ONLY.   2 STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2873	15041-10000-19197	6250 W HOLLYWOOD BLVD 15TH FLOOR	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			06/19/2015 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.10133	-118.32547	PC FOR POWER. NEW TI TO AN (E) HIGH RISE BUIILDING. RENOVATION OF THE 14TH FLOOR CONVERTING INTO CONDOS. TOTAL CONNECTED LOAD OVER 400AMPS. 8-200 AMP PANELS 145 CIRCUITS. LIGHTING AREA IN HALL WAYS IS EXISTING TO REMAIN FROM CORE AND SHELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2874	19041-10000-45645	3655 S 5TH AVE	90018	10	120B189  1534	5044028003	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.02127	-118.32252	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE 3.48KWdc / 3.00KWac.(12)MODULES- REC SOLAR: REC290TP2(1)INVERTER- NINGBO GINLONG TECHOLOGIES: SOLIS-1P3K-4G-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2875	17041-10000-13848	5529 N VAN NUYS BLVD	91401	4	174B149  1017	2249002022	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.17101	-118.44907	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  36000 SQ FT. OUTDOR LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2876	16041-10000-44350	3465 W 6TH ST #120	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.06373	-118.29761	Title 24 plan check only.  Total area = 947 sq. ft. T.I. to existing commercial space.  Change of use from retail to restaraunt.  One new panel with new lighting and kitchen loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2877	13041-10000-01853	8401 N VAN NUYS BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM			PC Approved	01/25/2013 12:00:00 AM	ADDRESS	34.22308	-118.44896	T24 ONLY FOR RETAIL SPACE. TOTAL AREA OF 4090 SQ FT. REARRANGMENT OF LIGHTING FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2878	19041-20000-31146	675 S KOHLER ST	90021	14	126A213   621	5147032001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			08/09/2019 12:00:00 AM	02/29/2024 12:00:00 AM		Issued	02/29/2024 12:00:00 AM	ADDRESS	34.03792	-118.24213	Plan check for power and energy with 800A Service. Scope of work includes panels, equipments and energy plan check. Total area: 9980 sq ft. B#18016-20000-31306	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2879	17041-10000-19094	8101 W LAURELMONT DR	90046	4	153B173   754	5565018054	RE15-1-H	Central	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.11305	-118.3709	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2880	19041-20000-04025	7026 N MIDDLESBURY RIDGE CIR	91307	12	183B089   190	2028047001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.19952	-118.64546	Plan check for a PV1 roof-mounted PV system. System size is 5.94 kWdc/7.6 kWac and consists of (1) inverter, (18) modules, (1) auto-transformer, (1) back-up battery unit, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2881	17041-20000-03089	16633 W VENTURA BLVD ste 902	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.15823	-118.49571	ti to an existing space.  change of use from retail to medical office in high rise building.  plan check for power and energy.  total square footage 1870.  scope in suite 902.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2882	15041-20002-12842	11952-11954 W VENTURA BLVD	91604	2	162B169   153	2369016032	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.14327	-118.39243	02-05-16 Change to approved set of plans. Changes include location of equipments(compressor and vacuum), Emergency bug eyes and additional lighting fixtures. Changes apply to delta 3 only. ***************Changes to an approve set. all changes made under delta 2. Replacing indoor and outdoor lighting. (((Plan check for T.I.  Dental office(Medical Office). Total area: 2082 sq ft. New 400A service upgrade.)))*************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2883	18041-20001-05896	13796 W FOOTHILL BLVD 101	91342	7	225B153   466	2509019005	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM			PC Approved	03/05/2018 12:00:00 AM	ADDRESS	34.30984	-118.43378	Plan check for Title 24 Part 6 requirements per inspector correction notice. (((additional outlets and circuits)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2884	14041-20000-35051	3433 E ALICE ST	90065	1	147A219   237	5454027002	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.09659	-118.2259	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZE 7.6 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(22) SUNPOWER E20/327MODULES(2) POWER ONE PVI3.8 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2885	19041-20001-48241	19665 W LOS ALIMOS ST	91311	12	210B117   313	2708022029	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.26841	-118.56225	Revisions to approved set of plans.  Change from string inverter to microinverter.  System description is now: 14.8 kW roof mounted PV system, (40) modules with microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2886	13041-10000-06604	815 S INDIANA ST	90023	14	121-5A229  76	5188008020	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	03/21/2013 12:00:00 AM	ADDRESS	34.02483	-118.19248	13041-10000-06604T24 FOR CHANGE OF USE FROM OFFICE SPACE TO GROCERY STORE (99 CENT STORE). UPGRADING THE SERVICE TO 400A. 4099 SQRFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2887	17041-10000-16774	2205 W SAN FERNANDO ROAD	90065	1	150B213   881	5442004034	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.10354	-118.23752	711 STORE TI. PC T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2888	13041-10003-27681	170 N GLENDALE BLVD	90026	1	135A209   230	5160013013	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.0639	-118.25974	(((CHANGES TO APPROVED PLANS. REMOVE 3 PANELS)))  PERMIT IS ISSUED UNDER THIS PC #. ALL PREVIOUS PC #'S ARE PLAN CHECK ONLY. 10002:][][CHANGES MADE TO APPROVED SET OF PLANS; REDUCING NUMBER OF MODULES FROM 24 TO 17 PER BUILDING REQUEST, AND DOWNSIZING INVERTER FROM 5kW TO 4 kW, TRANSFORMER TO TRANSFORMERLESS . NO ADDITIONAL CHANGES PER APPLICANT][][]original:PV2. ROOF MOUNTED 6.0KW DC PHOTOVOLTAIC SYSTEM ON STEEL CANOPIES ATTACHED TO COMMERCIAL BUILDINGS. (170 AND 180 GLENDALE AVE.) USING (24) LUMOS LSX 250 MODULESAND (1) SMA SUNNY BOY 5000US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2889	16041-20000-20285	515 S FLOWER ST STE 1200	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR OFFICES. HIGHRISE. SUITE 1200.  6,874 SQ FT .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2890	10041-10000-20802	1100 S GLENDON AVE STE 2000	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	FULL FLOOR T.I. TO CREATE OFFICES, CONFERENCE ROOM AND RECEPTION. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2891	16041-10000-22280	6360 W SUNSET BLVD	90028	13	147A187   584	5546015047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Expired	07/30/2018 12:00:00 AM	ADDRESS	34.09774	-118.32782	PC FOR OUTDOOR LIGHITNG FOR WALKWAYS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2892	14041-20000-04099	3109 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.03003	-118.37367	T.I. to existing space for Ubiquiti Network.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2893	18041-20000-15984	20812 W COMMUNITY ST	91306	3	192B109   951	2780005073	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Issued	05/01/2018 12:00:00 AM	ADDRESS	34.22113	-118.58686	Plan check for PV roof mounted system. System size: 7.6kW with 25 modules and 1 inverter(7.6kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2894	11041-10000-05807	145 S FAIRFAX AVE Suite #400	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	05/02/2011 12:00:00 AM	PIN	34.07292853	-118.36175524	TI IN AN EXISTING OFFICE AREA ON THE 4TH FLOOR IN SUITE #400. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2895	15041-10000-09626	3311 N BARHAM BLVD	90068	4	159B181   441	5579015003	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.13131	-118.34515	(N) fire alarm system for 2-story commercial office and classroom.  One FACP and (20) new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2896	18041-20000-24074	1800 N VINE ST 1st Floor	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Issued	09/10/2018 12:00:00 AM	ADDRESS	34.10393	-118.3265	Plan check for Title 24 only. Project site is the 1st floor of a 3-story commercial building. Project scope is a tenant improvement. Total lighting area = 13,310 sq. ft.Note: Building application has been generated under 18016-10000-14441	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2897	09041-10003-24382	10329 W PALMS BLVD	90034	5	120B161   400	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2699.07	Electrical	Electrical	Apartment			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.02679	-118.40832	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 09041-10000-24382. DELTA 3 ONLY. ADDDITION OF KEY NOTE 4.*****************************************************************************New Mixed Use project - core for retail / apartment (3-7 typical; 31 units) / parking - Permit is for new service (120/208), new distribution, new panels, new equipment, new ckting for residential / commercial use.  P/C is for Power and Energy. Modification to seperate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2898	15041-20000-06338	3423 W CASITAS AVE	90039	13	153B209    91	5436004020	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.119	-118.25508	Title 24 plan check only.  Total area = 100 sq. ft.T.I. to existing commercial space.  Remodel of two bathrooms including relocation of walls and new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2899	16041-10000-13367	2049 S CENTURY PARK EAST 8TH FL, LO-BBY	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR T24 ONLY. T.I. IN LOBBY AREA , CENTURY PLAZA TOWERS. TOTAL AREA 350 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2900	17041-20000-26120	6255 W SUNSET BLVD Suite 750	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 4,213 sq. ft.Note: Building application has been generated under 17016-10000-18821	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2901	17041-20001-21333	3470 W WILSHIRE BLVD	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Issued	07/19/2018 12:00:00 AM	ADDRESS	34.06152	-118.3001	Plan check and supplemental permit: Plan check: changes to approved set.  Changes to conductor sizing and insulation types.Supplemental permit: change of contractor on permit record per notarized property owner letter.  (((Plan check for a PV2 roof-mounted PV system. PV system installation on a parking canopy on top of a parking structure. System size is 300 kWac and consists of (5) inverters, (1,044) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222. Building permit  # 17014-20000-03029)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2902	19041-10000-27711	12665 W VILLAGE LANE	90094	11	102B161  1259	4211034106	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	07/24/2021 12:00:00 AM	ADDRESS	33.97786	-118.41484	Energy plan check for a storage room T.I located on the ground floor of an apartment building. Scope includes new lighting and equipment with a total lighting area of 371-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2903	13041-20000-35222	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/27/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	INSTALLING WALL ART IN EXISTING HOSPITAL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2904	13041-10001-24096	2920-2930 W ROWENA AVE BLDG 6	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.10823	-118.26884	CHANGES MADE TO PREVIOUSLY APPROVED SET.  A) ADDITION OF PV TO EACH RESIDENTIAL UNITB) REMOVE LIGHT FROM GARAGEC) ADDITONAL J BOXES IN RESIDENTIAL UNIT FOR FANS, LIGHTS, ETC.D) REMOVE LIGHT (FL) AND REPLACE WITH INCANDESCENT WITH DIMMER IN HALLWAYS(((TOWN HOUSES BUIILDING 6 OF 6. SERVICE SIZE IS 600 AMPS. 10 DWELLING UNITS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2905	10041-20000-13439	1230 N COLE AVE	90038	13	144B185   214	5533003022	R3-1XL	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Apartment			07/14/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.09384	-118.32969	plan check new installation for 28.98 KW photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2906	17041-10000-01011	11061 W LONGFORD ST	91342	7	213B173   276	2529025022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.27842	-118.37247	PLAN CHECK FOR PV ROOF MOUNTED SYSTEM. SYSTEM SIZE: 5.0KW WITH 22 MODULES AND 1 INVERTER(5.0KW)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2907	12041-10000-00307	1745 N VERMONT AVE	90027	4	147B197    89	5589028030	C4-1D	Central	Hollywood	Greater Griffith Park		1892.01	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM			PC Approved	01/05/2012 12:00:00 AM	ADDRESS	34.10277	-118.29205	Existing one story with mezz, kitchen existing, title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2908	15041-20000-29120	13281 W VAUGHN ST	91340	7	213B157   260	2524021021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM			PC Info Complete	09/15/2015 12:00:00 AM	ADDRESS	34.28173	-118.42257	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.57 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2909	13041-20001-18374	1601 S MAIN ST	90291	11	106-5A145   3	4238014017	C2-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Closed	01/23/2018 12:00:00 AM	ADDRESS	33.98776	-118.47116	Plan check for power and energy remodel of commercial space. Load is over 400A. Methane zone. Use of space will be movie studio headquarters. Silver Pictures Entertainment. Fire alarm is existing per applicant. (((changes to approved set of plans. changes include drawings for terrace and new circuits for it. all changes clouded delta 3. plan check for delta 3 only))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2910	12041-20003-18057	630 W HARRY BRIDGES BLVD Main Bldg	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	04/17/2013 12:00:00 AM	ADDRESS	33.77068	-118.26868	Methane Zone, Modification to previously approved set of drawings.  Addition to the scope of work on main application.NEW ADMINISTRATION BUILDING.  EPC IS FOR POWER AND ENERGY.  FIRE ALARM IS SUBMITTED SEPARATELY.  Methane detection system is on a separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2911	14041-20000-06972	13312 1/2 S VERMONT AVE	90247	15	078B197   176	6117031005	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Closed	01/08/2016 12:00:00 AM	PIN	33.9109622	-118.2912283	PV1 MICROINVERTERS. TOTAL SYSTEM SIZE 3.2KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2912	11041-20000-22567	127 S SAN VICENTE BLVD Bulletin-111TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM			PC Approved	10/21/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta #111TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2913	19041-10000-53408	616 S STANFORD AVE	90021	14	126A213   213	5147029041	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	07/09/2020 12:00:00 AM		Issued	07/09/2020 12:00:00 AM	ADDRESS	34.04026	-118.24307	$0 Fee due to AB1414. PV2. NEW 139KVA ROOFTOP COMMERCIAL SOLAR SYSTEM WHICH CONSIST OF 557 MODULES (SW FREEVOLT 300W) AND 7 CENTRAL INVERTERS ( 5xFRONIUS 20.0, 1xFRONIUS 24.0, 1xFRONIUS 15.0).SCOPE INCLUDES NEW 150 KVA TRANSFORMER. THE SYSTEM IS CONNECTED TO AN EXISTING 400A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2914	15041-20000-40188	6256 N TOPANGA CANYON BLVD Building B	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.18496	-118.6049	0$ permit fees due to senate bill 1222Plan check for a PV2 roof-mounted PV system. System size 56 kWac and consists of (2) inverters, (1) load center, and (228) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2915	16041-20001-40396	10909 W HAMLIN ST	91606	2	180B173   665	2414028022	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			Reviewed by Supervisor	11/22/2016 12:00:00 AM	ADDRESS	34.18861	-118.36848	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (10) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2916	15041-20000-17439	3616 S TROUSDALE PKWY	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.01983	-118.28534	Plan check for Title 24 only. Project site is the basement level of an existing commercial building (USC). Project scope is a tenant improvement. Total lighting area = 2,066 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2917	16041-10000-37979	555 W 5TH ST 3310	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR 1640 SQ FT OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2918	10041-20000-09442	3670 S MIDVALE AVE 1-6	90034	11	117B161   314	4252027015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Public Safety Only			05/19/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	07/07/2010 12:00:00 AM	ADDRESS	34.01883	-118.41247	Plan check for replacing FACP to an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2919	14041-10000-21657	1822 W JAMES M WOOD BLVD	90006	1	130-5A203 151	5136009001	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM			PC Approved	08/12/2014 12:00:00 AM	PIN	34.05208888	-118.27633845	PLANECHECK FOR T24 ENERGY. STORAGE SPACE. EMERGENCY LIGHITNG. PERMIT PREVIOUSLY PULLED UNDER 14041-20000-20837.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2920	16041-20000-41064	5845 N PENFIELD AVE	91367	3	174B113    33	2153004032	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.17705	-118.57018	PV1.  Install 12.23 kW roof-mounted grid-tied PV system.  (39) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2921	16041-10000-05082	10054 N ANDASOL AVE	91325	12	204B129   412	2734032001	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.25361	-118.51314	PV 1 roof mouted solar system installation to a single family home with a central invrter of 6.0 kw and 28 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2922	19041-10000-23129	333 S LUCERNE BLVD	90020	4	135B189   298	5505018014	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.06787	-118.32457	(ePlan) Install 2 Energy Storage System @13.5KWH each & 1 New 125A Load Center & 1 New 200A Load Center.*Note; 200A New Main Service Panel shall be under separate express permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2923	10041-10000-23593	2110 W 7TH ST 2nd & 4th-floor	90057	1	132A203   100	5141018002	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM			No Progress	11/24/2010 12:00:00 AM	ADDRESS	34.0565	-118.27737	Change of use from retail to restaurant. EPC is for Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2924	17041-20000-31941	9841 N AIRPORT BLVD Ste 1410	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	Plan check for Title 24 Part 6 only. Project is TI to an existing commercial high-rise building office suite.  Total lighting area = 2,289 sq ft.Building permit filed under 17016-10000-11478	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2925	16041-10000-42441	5800 W SUNSET BLVD STAGES 7&8	90028	13	147A191   236	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PC FOR POWER AND ENERGY. ADA UPGRADE A T.I. FOR STAGE 7 & 8 FOR A TELEVISION STUDIO. (E)  MEDIUM VOLTAGE SERVICE 4160 V, 2000A. TOTAL AREA 13844 SQ FT.B#16016-10000-24889	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2926	18041-20000-18782	1259 N BEVERLY ESTATE DR	90210	5	144B157   115	4356013005	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM			PC Approved	09/18/2018 12:00:00 AM	ADDRESS	34.09395	-118.42792	New 2-story single-family dwelling and an accessory living quarter. Work includes a 600A 240/120V 1ph-3w service.Note: Building application has been generated under 16010-20000-01378 and 16010-20000-01379	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2927	16041-20000-45451	258 S SERRANO AVE	90004	10	135B193   136	5517013027	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.06949	-118.30651	PV2.  Install 19.7 kW AC roof mounted grid tied PV system.  (70) modules with (2) 6kW and (1) 7kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2928	19041-10000-16526	2855 W AVENUE 35	90065	1	154-5A215 262	5457026011	[Q]CM-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/13/2019 12:00:00 AM	ADDRESS	34.11617	-118.23605	TI IN AN EXISTING COMMERCIAL BULDING.  INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.PLAN CHECK ONLY. AB-1414 (No fees required)PERMIT#: 19041-10000-10945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2929	18041-10000-20881	1349 W 1ST ST	90026	14	135A209   449	5160013039	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			06/05/2018 12:00:00 AM	10/04/2021 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.06191	-118.2592	New 7-story mixed use with 103 apartment units over 2900 sf retail and subterranean parking garage. The 5-story apartment on top of 2 levels of parking/retail/lobby over the subterranean parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2930	12041-10000-08252	8325 N LAUREL CANYON BLVD	91352	6	192B165   411	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	12/11/2012 12:00:00 AM	ADDRESS	34.22241	-118.39768	T.I. to an existing Ralph's Grocery store.  New circuits, loads, lighting.  Full plan check requested by applicant for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2931	13041-10000-34516	2037 S LA CIENEGA BLVD	90034	10	126B173   885	4302034024	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.03915	-118.37756	"PLAN CHECK FOR POWER AND ENERGY TO (E)  SINGLE-STORY CHURCH. NEW 800A, 120/204, 3PH, 4WIRE MAIN SWITCHBOARD ""MS"" , 4 NEW PANELS, LIGHTING RENOVATION IS FOR INDOOR AND OUTDOOR TOTALING TO 39,203 SQ FT OF AREA.FA variance was submitted"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2932	17041-10000-39238	18518 W TORREY PINES LANE	91356	3	165B125   472	2184053015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/04/2017 12:00:00 AM	ADDRESS	34.14455	-118.53503	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.04KWdc / 10.24KWac. (32)AC MODULES- SUNPOWER SPR-X21-345-D-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2933	16041-10000-42033	660 S FIGUEROA ST SUITE 1650	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2934	12041-10000-07289	175 S FAIRFAX AVE UNIT D	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	New coffee shop, first time tenant.  1200A service.  Plan check for Power and Energy. This is for pete coffee unit D.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2935	19041-10000-17591	1166 E 58TH ST	90011	9	108B209  1380	5104031014	MR1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.99007	-118.25487	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2936	12041-10000-24300	5401 S MCCONNELL AVE	90066	11	102B157    31	4211009013	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	33.97848	-118.42025	Ti in an existing office. New lighting and switches. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2937	17041-10000-14907	21800 W OXNARD ST #1100	91367	3	177B105    81	2146006046	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.17898	-118.60253	PC for energy only.  TI  for office space Total affected area 2787 sq.ft.Scope includeds new lights and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2938	12041-10000-04717	1901 S AVENUE OF THE STARS #130	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.05949	-118.41705	T.I. for an existing high-rise office building.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  ((Permit fees are under Inspection))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2939	18041-10001-31390	1542 N TOWER GROVE DR	90210	5	147B157   255	4356019021	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.09821	-118.42574	*Expedited Fee per applicant**Install Ground mounted PV system with ESS. Install: (98) modules;   (2) 14.4 kW AC central inverters,  and (1) 7.6 kW AC central inverter that connects to (2) ESS, which  are connected to the Emergency Back-up Panel and routed through (E) ATS and (E) generator; (2) New 100A subpanel, (1) 10 kVA transformer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2940	23041-20000-01906	7053 N OWENSMOUTH AVE	91303	3	183B105   455	2138004022	P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			PC Approved	08/05/2020 12:00:00 AM	ADDRESS	34.19886	-118.60173	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2941	18041-10001-10985	767 S ALAMEDA ST BLDG2-3RD FL COR	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM			PC Approved	04/18/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	CHANGES TO APPROVED SET DUE TO FLOOR PLAN (ARCHITECTURAL) REVISION, CHANGES NOTED AS DELTA-1. THIS IS PLAN CHECK ONLY, NO ADDITIONAL PERMIT IS REQUIRED. PERMIT IS COVERED UNDER MASTER PLAN # 18041-10000-10958<<ALTERATIONS IN CORRIDOR ON 3RD FLOOR OF BUILDING 2PLAN CHECK IS FOR TITLE 24>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2942	19041-10001-17470	6502 N VAN NUYS BLVD	91401	6	180B149   597	2237014006	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM			Reviewed by Supervisor	05/20/2019 12:00:00 AM	ADDRESS	34.18884	-118.44845	EXPEDITE PER APPLICANT REQUEST ((PV2. NEW ROOFTOP COMMERCIAL SOLAR SYSTEM CONSIST OF 168 MODULES (TRINA SOLAR 360), 2 CENTRAL INVERTERS ( SUNNY TRIPOWER 30KW EACH) AND ONE 75KVA TRANSFORMER. SYSTEM SIZE IS 60.48KWdc AND 60KWac))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2943	19041-10000-53725	5300 N VAN NUYS BLVD	91401	4	172-5A151  69	2248014008	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	06/01/2020 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.16709	-118.44848	Title 24 energy plan check. Scope of work includes 1 new circuit. Total affective area: 5950 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2944	15041-20000-18447	3587 S OCEAN VIEW AVE	90066	11	114B153   664	4248025041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.00879	-118.43601	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.PC FOR PV1 SFD. TOTAL SYSTEM SIZE 19.6KW AC USING 58 MODULES. TRANSFORMERLESS INVERTERS. TOTAL OF 4 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2945	12041-10000-09731	811 W 7TH ST 1ST FLR	90017	9	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	07/30/2012 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.04908	-118.25911	PLAN CHECK FOR POWER AND ENERGY FOR RESTAURANT ON FIRST FLOOR OF AN HIGH RISE BUILDING. MORE THAN 99 OCCUPANTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2946	14041-10001-34785	10900 W MAGNOLIA BLVD	91601	2	171B173  1381	2419001041	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.16471	-118.3681	Change to approved set by modifying the lighting and adding new circuits to the floor plan. permit needs to be pulled for new circuits.    (((TI existing ralphs market. T24. Total area = 32,413 sq. ft. Decor lighting)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2947	10041-10002-22580	13720 W RIVERSIDE DR	91423	4	168B157   318	2269025002	C2-1, C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM			PC Approved	04/28/2011 12:00:00 AM	ADDRESS	34.15674	-118.43273	Modification to the original appproved set of plans modified to show compliance with T24 switching and shut off controls.  Veirified that the Trane Tracker is indicated in the California Energy Appliance Dataa Base and is UL Listed as an EMS.  Verify Trane Tracker  Model BMTX********with 4950 0*90.  See local area and display lighting control switches on the lighting plan drawings.  The EMS control system is located in the maneger's office room 107, and the I/O control is located in electrical room 113.   REMODEL OF (E) RETAIL SPACE - SPORTS AUTHORITY -INCLUDING DOORS, PARTITIONS, CEILING, FIXTURES, LIGHTING, MEP WORK; 46,432 SQ (BASEMENT TO 2ND FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2948	19041-10001-19550	1546 S EDRIS DR	90035	5	129B165   398	4306013011	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2019 12:00:00 AM			PC Approved	06/25/2019 12:00:00 AM	ADDRESS	34.05105	-118.39739	Expedite per applicant request((PV1. NEW ROOFTOP SOLAR SYSTEM CONSISTING OF 32 AC MODULES ( SUNPOWER 327). SCOPE INCLUDES 125A SUBPANEL .Note: Panel unpgrade shall be pulled under express permit))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2949	16041-20000-41927	3506 W GARDEN AVE	90039	13	153B209   378	5437007007	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	ADDRESS	34.11662	-118.26044	Plan check for installation of solar pv system, roof-mounted on duplex. Interconnect with a 200A MSP.3kW ungrounded system. (9) 285W pv modules. Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2950	16041-20000-44175	8460 N PENFIELD AVE	91306	3	192B113   270	2782010033	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Issued	01/03/2017 12:00:00 AM	ADDRESS	34.2237	-118.56872	permit fee $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 12.7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2951	13041-10000-10646	358 N LA BREA AVE	90036	5	138B181   131	5525032027	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Expired	06/24/2015 12:00:00 AM	ADDRESS	34.07786	-118.34383	RENOVATION OF EXISTING BEAUTY SALON. CHANGE OUT LIGHTING FIXTURES TO LED FIXTURES AND ADDITION OF NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 1583 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2952	14041-10001-27276	15622 S VERMONT AVE	90247	15	072B197   334	6120004011	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.88918	-118.29142	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 11.44 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. 3 STRINGS.(44) MODULES: WINIACIO WSP-260P6(44) MICROINVERTER(S): ENECSYS SMI-240W-60-UL>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2953	17041-20000-43038	9126 N LANGDON AVE 1-15	91343	7	198B145   349	2656026027	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.23653	-118.46964	Plan check for a fire alarm system for a 3-story, 15-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (63) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2954	18041-10000-33052	20215 W SATICOY ST	91306	3	186B113   166	2114004017	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.20847	-118.57375	Energy plan check for an existing commercial building with new lighting and equipment. Note. Portion of the permit fee is paid under application number 17041-20000-18412.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2955	18041-20000-04597	1000 N ONEONTA DR	90065	1	153A221    91	5475012030	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.11484	-118.21481	Plan check for the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2956	12041-20000-17447	18600 W DEVONSHIRE ST Service-Building	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.25704	-118.53922	New electrical for remodeled service building.  Plan check for T-24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2957	17041-20001-20932	5946 N FAIRHAVEN AVE	91367	3	177B089   837	2046004***	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Approved	06/29/2017 12:00:00 AM	ADDRESS	34.17715	-118.65387	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2958	18041-10000-04579	10901 W WILSHIRE BLVD	90024	5	132B153   344	4363023032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			PC Info Complete	02/16/2018 12:00:00 AM	ADDRESS	34.05884	-118.44466	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR WORK ONLY. TOTAL AFFECTED AREA 5815 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2959	16041-20000-13734	3470 S TROUSDALE PKWY 5th Floor	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.02202	-118.28393	Plan check for energy only. TI to existing office space. Divide one existing office into two separate offices in suite #504J. New lighting and receptacles. 204sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2960	15041-10002-40734	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Issued	10/31/2016 12:00:00 AM	ADDRESS	34.04538	-118.26389	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED ON PLANS ISSUE 11. CHANGES INCLUDE REVISION TO EMERGENCY DISTRIBUTION AND SUPPLY FOR FIRE PUMP. REVISED SOME LOADS. CHANGES CLOUDED ON PLANS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2961	14041-10001-20668	13425 S FIGUEROA ST	90248	15	078B201    80	6132004024	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	PIN	33.90971921	-118.28334947	"(8/26/2014 - Title 24 plan check at request of inspector.  Total area = 27,363 sq. ft.  Alteration to east exit corridor affecting emergency lighting, addition of 2nd floor of retail store with new stairway, new exit ramp.  All panels remain existing.  Building application submitted before title 24 part 6 effective date.))Master permit work description: Relocate light fixtures and remove (2) switches          ""COMPLY WITH DEPARTMENT ORDER effective date09/17/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2962	16041-20000-45608	11755 W WILSHIRE BLVD 24th flr	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	PIN	34.04869377	-118.46238681	ti to an existing commercial building(restroom) of a high rise building.  adding new lighting new controls to existing panels.  plan check for energy only toal square footage 412.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2963	16041-20001-19398	3239 N PASADENA AVE Unit A	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	RSES expedited plan check per applicant request.  PV2.  Install 1.71 kW DC roof mounted PV system.  (6) modules with (1) 3 kW transformerless inverter with power optimizers.  1 of 3 PV systems proposed for property submitted concurrently.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2964	12041-10000-27477	3525 W 8TH ST	90005	10	132B193   572	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.05782	-118.30714	CHANGE OF USE FROM RETAIL TO COFFEE SHOP.   TI FOR COFFEE SHOP; BUILD A RESTROOM; BUILD A COUNTER TOP; INSTALL FIXTURE IN KITCHEN;Plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2965	15041-20000-33299	1117 S NORMANDIE AVE	90006	10	129B193   703	5078019004	R4-1VL	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Expired	11/16/2017 12:00:00 AM	ADDRESS	34.0503	-118.3002	PV1, roof mounted solar 6.39 kW AC, (27) modules: Q.PRO- BFR-G4 260, (1) inverter: Solar Edge -SE600A-US, (27) solar edge power optimizer P300	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2966	18041-20000-40477	9806 W VIDOR DR	90035	5	132A165   312	4330005016	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM	08/03/2020 12:00:00 AM		Permit Finaled	04/28/2023 12:00:00 AM	ADDRESS	34.05449	-118.40295	New 800A 240/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2967	16041-10000-14967	602 E IMPERIAL HWY	90059	15	087A207   290	6072004026	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	33.93089	-118.26465	PC FOR ENERGY. TI - NON-STRUCTURAL REMODEL AT EXISTING RETAIL BUILDING.  CHANGE OF USE FROM RETAIL TO AN OFFICE (FINANCIAL LENDER).  TOTAL AREA 1026 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2968	16041-10007-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM			PC Approved	09/17/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	(This is plan check only, permit is covered under master) DELTA 16 & 17 CHANGES ONLY.  SOW: REVISE T24 TO ADD VALET RAMP LIGTS, REVISE SLD TO SHOW EV METER AND FUSED DISCONNECT, REVISE PANELS EMP2H1 & P2H1B TO REFLECT ADDITION OF VALET RAMP LIGHT, REVISE HOMERUN TO SHOW VALET RAMP LIGHTS, REVISE ELECTRICAL ROOM FLOORP LAN TO SHOW LOCATION OF EV METER.<<<<PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT.>>>>>>>>>> BUI;DING APPLICATION 16010-10000-04147	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2969	18041-10000-44244	314 W 6TH ST	90014	14	129A211   159	5144003016	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			11/19/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	05/12/2022 12:00:00 AM	ADDRESS	34.0468	-118.25247	INSTALLATION OF NEW FIRE ALARM 260 DEVICES ON LOW RISE APARTMENT BUILDING SCOPE OF WORK INCLUDES (1) FIRE ALARM AND (4) CONTROL PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2970	13041-20003-35614	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	33.98179	-118.40283	3/4/2015 Changes to an approved set of plans. Changes include the change of feeder material from copper to aluminum. This change has only been done for feeders rated 100 amps or larger. All changes have been clouded and marked as Delta VE.((10/28/2014 - Sup. application for changes to approved set.  Removing some lighting fixtures and change of service from overhead to underground))PLANCHECK FOR POWER AND ENERGY. CORE AND SHELL. NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY 29895 SF WITH NEW SURFACE PARKING LOT1 OF 2. BUILDING 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2971	10041-20000-09904	10508 W SANTA MONICA BLVD	90025	5	132B157   992	4317003003	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	10/06/2010 12:00:00 AM	ADDRESS	34.05508	-118.42694	OFFICE T.I.ENERGY ( INTERIOR & EXTERIOR ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2972	14041-20001-07064	10155 N JANETTA WAY	91040	7	204B173   162	2542031025	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.25537	-118.3662	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2973	14041-10000-01156	5507 W HOLLYWOOD BLVD	90028	13	148-5A193 129	5544005024	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.10192	-118.30983	PLAN CHECK FOR POWER AND ENERGY FOR A ONE STORY STORE FOR PETCO WITH EMERGENCY LIGHTING, TOTAL  AREA 13964 SQ FT.  FA plan to be submuitted seperatly.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2974	18041-20003-15813	9540 N VASSAR AVE	91311	12	201B105   236	2746016055	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			PC Approved	08/16/2019 12:00:00 AM	ADDRESS	34.24413	-118.60451	08/16/2019 Changes to an approved set of plan, Changes include update series rating combination on 480Volt distribution and 240Volt distribuiont and addtion conductor for netural. Changes has been clouded. as delta 3. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2975	17041-10000-36287	8528 W APPERSON ST	91040	7	204B189   649	2560020025	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Expired	03/31/2024 12:00:00 AM	ADDRESS	34.25601	-118.31894	PC for 7.6kW rooftop PV installed in single family. Installing new SE7600 central inverter, 28 modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2976	19041-10001-50279	8040 W MANCHESTER AVE Bld-A	90293	11	096B153   618	4118002101	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM			PC Approved	03/04/2020 12:00:00 AM	ADDRESS	33.95901	-118.43632	Expediter per applicant request.Plan check for a 57.6KW AC/ 62.2KW DC roofmonted system. Scope includes (2) inverters, (143) modules and optimizer interconnecting through a load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2977	13041-10001-22316	15651 W RAYEN ST	91343	12	195B141   333	2672009034	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.23203	-118.47366	�Expedited plan check per applicant request�.PV1 12.99KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-5000-OUTD-US and PVI-6000-OUTD-US] [( 53) MOD: yingli {YL245-29b}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2978	12041-20000-14830	12422 W BLUFF CREEK DR Bldg 3	90045	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	PIN	33.97699492	-118.40662117	New building 3 core shell supplied from new 3000 ampere service equipment submitted under separate application, 12041-20000-14826.  Located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2979	19041-20000-25860	990 W 190TH ST STE 420	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Issued	07/08/2019 12:00:00 AM	ADDRESS	33.85813	-118.29505	T24 PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL SUITE 420. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 3269 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2980	16041-20001-35275	13512 W MINEOLA ST	91331	6	195B157    16	2625035009	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.23526	-118.42652	expedite per applicant.pv1install roof mounted pv system sized 9.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2981	18041-10000-35912	8550 N BALBOA BLVD #100	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.22649	-118.5024	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2982	13041-20000-03949	1490 S CARDIFF AVE	90035	5	129B169   276	4306005007	R2-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2013 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.05264	-118.39195	"15.7kw roof mounted PV system for a sfr with Battery Backup.""COMPLY WITH DEPARTMENT ORDER effective date07/22/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".Note: Application extension is submitted on 8/14/14."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2983	13041-20000-22613	20236 W ELKWOOD ST	91306	3	189B113  1032	2107022070	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.21222	-118.57428	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW USING 18 MODULES. TRANSFORMERLESS INVERTER, NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2984	18041-20000-41977	8109 S BARNSLEY AVE	90045	11	099B169   969	4105017022	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	01/26/2019 12:00:00 AM	ADDRESS	33.96544	-118.38451	Plan check for PV roof mounted system and energy storage device System size: 3.8kW with 1 inverter(3.8kW)  with existing modules and 1 Tesla PowerWall 2.0, 13.5kWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2985	15041-20000-04138	2545 S LINCOLN BLVD	90291	11	108B149  1019	4237029016	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	33.99117	-118.44873	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVMENT. Convert portion of existing basement pool to storage area to existing adult day care. 2223 QFT, INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2986	14041-10000-11710	7310 N RANCHITO AVE	91405	2	186B153   641	2216010028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.20348	-118.43544	PV1 ROOF TOP TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2987	13041-10001-19659	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			11/25/2014 12:00:00 AM			PC Approved	11/25/2014 12:00:00 AM	ADDRESS	34.09918	-118.32644	addition of supply fan for ladwp transformer room  ... m.z.  11-25-14)))))       POWER AND ENERGY PLAN CHECK 287 UNIT APARTMENT BUILDING WITH FUTURE RETAIL SPACES. 7 STORY  LOW RISE BUILDING. VARIANCE TO SEPERATE FIRE ALARM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2988	17041-10000-34464	211 S AVENUE 20	90031	1	138A221   176	5447024033	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.07213	-118.22001	0$ permit fees due to senate bill 1222, ab 1414PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 99.9KWac. B#17016-10000-28079(180) LG MODULES(180) OPTIMIZERS-SOLAREDGE(3) INVERTERS-33.3KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
2989	10041-10001-18425	3650 W MARTIN LUTHER KING, JR BLVD #268 B&C	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM			PC Approved	11/01/2010 12:00:00 AM	ADDRESS	34.01118	-118.33649	REVISIONS TO APPROVED SET OF PLANS - ADDED AND REMOVED LUMINAIRES RESULTING IN A GREATER LIGHTING DENSITY FOR THE SPACEREMODEL OF T-MOBILE RETAIL STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2990	17041-20001-01957	9301 N TAMPA AVE 71	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check only for energy code compliance per inspector correction notice.  1,033 sq ft.  Some new lighting for new spaces/ceiling height walls.  (((NEW PLUGS, OUTLETS AND SWITCHES. NO LIGHTS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2991	12041-10001-00150	8378 W MELROSE AVE #103	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM			PC Approved	02/28/2012 12:00:00 AM	ADDRESS	34.08341	-118.37285	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT ON EXISTING SPACE #103.  REVISION TO APPROVED PLANS 12041-20000-00150. ALL REVISIONS ARE CLOUDED ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2992	17041-20000-37864	3716 S HOPE ST	90007	9	117A203    30	5122025012	[T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM			PC Approved	10/20/2017 12:00:00 AM	ADDRESS	34.01651	-118.27956	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2993	19041-20001-30529	6050 N ELLENVIEW AVE	91367	3	177B085   282	2032015025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.1812	-118.65949	NEW ROOF MOUNTED 16.38 KW PV SYSTEM WITH 52 @ PV PANELS, 2 @ POWER WALLS AND 2 INVERTERS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2994	19041-30000-06855	1662 W PACIFIC COAST HWY	90710	15	033B193    59	7411004017	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	33.78922	-118.30629	Plan check for Title 24 only. Project site is an existing commercial building (car wash). Project scope is a tenant improvement. Total lighting area = 15,199 sq. ft.Note: Building application has been generated under 19016-30000-05369	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
2995	18041-10000-01301	7503 S EARLDOM AVE	90293	11	093B153   118	4117029002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	33.95357	-118.44313	PV1. ADDING A NEW SOLAR ARRAY TO AN EXISTING SOLAR SYSTEM FOR A SINGLE FAMILY HOME. SCOPE INCLUDES ADDING 4.35KWdc / 3.8KWac OF SOLAR TO AN EXISTING 1.29KWac. TOTAL SYSTEM SIZE WITH NEW AND EXISTING SYSTEM IS 5.09KWac.(15)MODULES-SOLARWORLD SW290W(15)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE3800H	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
2996	16041-10004-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	PIN	34.2363795	-118.55851216	REVISIONS TO PERMITTED SET OF PLANS-ATTACHED TO THE UPDATED PLANS IS A LIST OF CHANGES Bulletin 2, Delta 2. changes to the plans are clouded and marked as Delta 2   PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE 214 UNITAPARTMENT WITH RETAIL CORE & SHELL. 4 FLOORS OF RESIDENTIAL OVER 2 FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL.  THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMPS, 4000 AMPS, AND 1000 AMPS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
2997	15041-20000-18161	9016 N OWENSMOUTH AVE	91304	3	195B105    40	2779018014	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.23416	-118.60151	Plan check for power only. Project site is an existing building. Project scope is a tenant improvement. Work includes a service upgrade to 600 amps and the installation of (4) new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2998	14041-20001-24396	11715 W BELLAGIO ROAD 1-23	90049	5	141B145   477	4368014034	[Q]R3-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	34.07869	-118.46956	EXPEDITE FEESPV2 APARTMENT ROOFTOP SOLAR. TOTAL SYSTEM SIZE 10KW AC USING 3 PHASE INVERTER WITH 4 STRINGS. TOTAL OF 60 MODULES. NON STANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
2999	18041-10000-41547	425 E ROSE AVE	90291	11	111B141   387	4240007008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	33.99806	-118.47436	INSTALL A FIRE ALARM SYSTEM WITH 25 DEVICES WITH 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3000	18041-10000-42042	7346 N SEPULVEDA BLVD	91405	6	186B145   539	2221010008	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.20417	-118.46598	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3001	18041-20003-12297	1852 N MARCHEETA PL	90069	4	150B169  1092	5561008033	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.10612	-118.38882	12-18-2018 Changes to an approved set of plans, Changes include indicate existing distribution on floor plan. All Changes has been clouded. Plan check only. fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3002	17041-20000-29064	334 E SUNSET AVE	90291	11	109-5A143  67	4286007021	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	09/01/2020 12:00:00 AM	ADDRESS	33.99545	-118.47421	PLANCHECK FOR POWER AND ENERGY.  CORE AND SHELL. ROPOSED 6,000SF MANUFACTURING AND RELATED  USES/SOFTWARE, MUSIC, FILM AND VIDEO MANUFACTURING BLDG.BUILDING PERMIT #  17010-20000-02967	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3003	12041-10000-08595	3939 S CRENSHAW BLVD	90008	10	117B185  1015	5032002058	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM			Corrections Issued	04/16/2012 12:00:00 AM	ADDRESS	34.01358	-118.33646	T.I. New yougurt shop, previously a mailbox/copy store.  Occupancy load is 38, Load is 182A, per applicant.  PLAN CHECK ONLY for T-24, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3004	19041-10000-07134	1950 N TAMARIND AVE	90068	4	150A191    57	5586014062	RD1.5-1XL	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	11/01/2021 12:00:00 AM	ADDRESS	34.10678	-118.31904	ENERGY PLAN CHECK FOR AN INTERIOR MODIFICATION TO LOBBY, RECREATION ROOM, AND GYM. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 3398-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3005	18041-10000-06375	1234 W WILSHIRE BLVD Unit 101	90017	1	130-5A207 637	5143019***	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.05329	-118.26612	PC FOR POWER AND ENERGY FOR NEW TENANT SPACE ( 7/11 STORE). SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA  1561 SQ.FT B#17041-10000-07775	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3006	17041-20000-33224	726 N COLE AVE	90038	13	141B185   438	5533033030	CM-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.08428	-118.32968	New 120/240V 3ph-4w 600 A service and tenant improvement for an existing 3-story office building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3007	10041-20000-08668	7422 W MELROSE AVE	90036	5	141B181   602	5526019028	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	05/10/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	PIN	34.08334012	-118.35179976	Plan check T-24 Energy for barber shop and salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3008	18041-10001-02137	8466 S FIGUEROA ST	90003	8	097-5A201 129	6032035045	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	33.96195	-118.28249	expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3009	17041-20000-39932	12023 N MONOGRAM AVE	91344	12	216B137   219	2609029032	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.28872	-118.4913	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.89 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3010	14041-10000-35250	814 W 23RD ST	90007	1	123A203    94	5124029017	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.03246	-118.27812	installation of a fire pump with new controller and a new jockey pump , in an existing shed ,  power ahead of the main, 600 amps service, all encased in 2 inches of concrete. Transition from pvc to rigid additional grounding conductor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3011	10041-10000-16570	1224 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.05056	-118.22633	Solar voltaic system installed on the roof of the building.  Consists of 8 modules, 8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3012	18041-20000-30978	14073 N CARLTON LANE	91342	7	231B153   145	2582041***	(T)(Q)RD6-1, QRD6-1	North Valley	Sylmar	Sylmar	YES	1060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.32827	-118.44035	Plan check for a PV1 roof-mounted PV system. System size is 7.82 kWac and consists of (34) modules, (34) micro-invertes, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3013	15041-10000-34536	3100 N GLENDALE BLVD A-B	90039	13	154-5A207 404	5437008025	[Q]C4-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.1162	-118.2624	Title-24 plan check only.  Total area = 1,556 sq. ft.    T.I. to coffee shop in existing building.  New lighting, receptacles, and cooking equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3014	17041-20001-35687	3746 N HAWLEY AVE	90032	13	159B205   752	5594010016	(Q)RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.09066	-118.19042	expeditepv1install roof mounted pv system sized 3.8kw with powerwall (battery back-up) interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3015	17041-10000-16637	511 S HARBOR BLVD	90731	15	015B201    34	7455026051	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.73999	-118.27999	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 24000 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3016	15041-10000-31903	1565 W SEPULVEDA BLVD	90501	15	045B193   504	7347017069	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	33.81599	-118.30556	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 4681	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3017	15041-20000-29213	18219 W CHASE ST	91325	12	192B125   246	2786009021	R1-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.22473	-118.53011	Plan check for PV roof mounted system. System size: 16 kWac with 60 solar modules and 60 Enphase micro-inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3018	18041-10000-10658	9900 S SERVICE ROAD	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	33.94222	-118.42162	Plan check for power and energy  hazardous location in  LAX Project 5. Install 4 new jet fuel tanks in LAXFUEL. Outdoor lighting area: 54,000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3019	19041-20000-18619	6740 S BRYNHURST AVE	90043	8	102B185   488	4006022018	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Apartment			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	33.9769	-118.33366	Plan check for a fire alarm system. Site is a 3-story, 12-unit apartment building. Fire alarm system consists of (1) FACP and (41) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3020	16041-10000-12674	10780 W SANTA MONICA BLVD suite 300	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.0504	-118.43387	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 3RD FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SUITE 300. TOTAL AFFECTED AREA IS 330 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3021	12041-20000-29780	1654 N MANDEVILLE CANYON ROAD	90049	11	135B137   614	4426018030	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Expired	01/06/2015 12:00:00 AM	ADDRESS	34.0629	-118.49281	Photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3022	17041-10000-41833	4226 N IRVINE AVE	91604	2	165B169   746	2368014029	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.14626	-118.38542	$0 FEE DUE TO SENATE BILL 1222.PC FOR  ROOFMOUNTED PV ON SFD. SYSTEM SIZE 11.4 KWAC/ 16.0 KWDCSCOPE INCLUDES 39  MODULES  WITH OPTIMIZERS AND CENTRAL INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3023	10041-10001-23825	3335 S FIGUEROA ST 1st Floor	90007		120A203   177	5123009027	(Q)C2-2D-O		South Los Angeles	Empowerment Congress North Area			Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM			PC Approved	01/05/2011 12:00:00 AM	ADDRESS	34.02224	-118.28008	Changes to the approved plans. alterations in storage area on the first floor. plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3024	11041-20000-12445	127 S SAN VICENTE BLVD Bulletin-56TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Closed	02/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	BULLETIN #56TI REVISION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3025	14041-20001-20535	10913 N BAIRD AVE	91326	12	210B125   642	2717013002	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM			PC Approved	08/05/2014 12:00:00 AM	ADDRESS	34.26918	-118.53747	EXPEDITE FEESPV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. DERATING OF MAIN BREAKER. TOTAL 45 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3026	15041-10000-28779	7036 N RANCHITO AVE	91405	2	183B153   460	2216031022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM			Reviewed by Supervisor	09/16/2015 12:00:00 AM	ADDRESS	34.19867	-118.43552	PV 1, roof mouted solar system for a residential site. (36) modules, (2) inverters: 11kw. (1) load center: 125 amps.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3027	11041-20000-04716	2802 W 8TH ST	90005	1	132A201    60	5077022002	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			03/10/2011 12:00:00 AM			PC Approved	03/10/2011 12:00:00 AM	ADDRESS	34.0576	-118.28694	relocate swbd to east side wall of the same room  by dwp	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3028	14041-10000-13689	3430 S VERMONT AVE	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.02479	-118.29132	Install fire alarm system in modular class rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3029	17041-10000-19787	418 N NORTON AVE 1-35	90004	4	141B189  1146	5522022008	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			06/20/2017 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.07908	-118.3169	FULL PLAN CHECK FOR A  NEW 4- STORY , 35- UNIT APARTMENT BUILDING WITH  A GARAGE AT 1ST FLOOR .  FEE PROVIDED BY APPLICANT. *** PLAN CHECKER RECHECK TOTAL FEE PRIOR TO FINAL APPROVAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3030	13041-10003-25590	7640 N HASKELL AVE	91406	6	186B141    32	2206012029	(Q)CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.20957	-118.47474	"PV2. "" $0 permit fee is due to the 2012 Senate Bill No. 1222"" 150KVA Isolation transformer transformer installed per LADWP requirment. COMMERCIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM. TOTAL SYSTEM SIZE 100KW DC. USING (4) TRANSFORMERLESS INVERTERS SMA 20000TL. SUPPLY SIDE POINT OF INTERCONNECTION."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3031	13041-20000-27469	17521 W RAYEN ST	91325	12	195B129   196	2768026011	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.23233	-118.51668	"PV1 TRANSFORMERLESS WITH SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 11KWAC."" low permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3032	18041-10000-10129	12855 W RUNWAY ROAD 1ST FLOOR	90094	11	102B157   395	4211033054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			PC Info Complete	07/30/2018 12:00:00 AM	ADDRESS	33.97556	-118.41956	INTERIOR TENANT IMPROVEMENT TO CONVERT A  STORAGE ROOM TO  A  PARCEL  MAIL ROOM ON 1 ST FLOOR OF ( E ) FIVE- STORY APARTMENT BUILDING.  PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3033	13041-10000-08106	1243 N LAS LOMAS AVE	90272	11	132B125    62	4420008018	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.05464	-118.53608	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.29KW. USING 42 MODULES. STANDARD PLAN CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3034	18041-20001-41096	11247 W TUXFORD ST	91352	6	195B173   255	2408036040	M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.23086	-118.37673	RELOCATOIN OF SERVICE EQUIPMENT. DELTA 1 CHANGES ONLY.ORIGINAL SCOPE : 2000A 480Y/277V service upgrade to (E) industrial light manufacturing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3035	12041-20000-26625	770 W WILSHIRE BLVD 7TH FLOOR	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.04914	-118.25811	Install power circuits and remove and reinstall lighting fixtures with new switch and occupancy sensor controls for  a remodel portion of the 7th floor.  T-24 lighting plan check only for remodeled portion of the 7th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3036	14041-20000-01236	5700 N CANOGA AVE #160	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.17365	-118.59715	Change to lighting in an existing low-rise office building.  Load is approximately 50 amps per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3037	14041-20000-26564	7701 N PENFIELD AVE	91306	3	189B113  1228	2106008018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.21072	-118.56915	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(27) SolarEdge P300 power optimizers(27) Kyocera KD255GX-LFB3 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3038	15041-20000-04074	17932 W VENTURA BLVD	91316	5	171B129   276	2182001002	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.16383	-118.52324	Plan check for energy and emergency lighting. Restaurant. low rise. Sandwich Bar 26.  total square footage 1347.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3039	18041-10000-01035	1122 S LA CIENEGA BLVD	90035	5	132B173   837	5087002020	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	ADDRESS	34.05628	-118.37598	TITLE 24 PLAN CHECK, SCOPE OF WORK INCLUDES NEW LIGHTING AND EXIT SIGNS IN TWO RESTROOMS AND CORRIDORS. TOTAL SQ. FT. 216.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3040	14041-20000-15803	650 W USC MC CARTHY WAY B13-B16	90089	9	118-5A201   5	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Closed	09/29/2014 12:00:00 AM	ADDRESS	34.02117	-118.2829	pc for t24 energy only. new lighting in existing classrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3041	15041-10000-26927	12625 N GLENOAKS BLVD	91342	7	219B153   136	2508027012	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.29948	-118.43958	PC for hazardous location, new gas station. Class 1 division 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3042	13041-20000-29247	855 S BROADWAY	90014	14	127-5A209 313	5144017***	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.04258	-118.25615	PER APPLICANT REQUEST, FULL PLAN CHECK FOR POWER AND ENERGY. RETAIL. PART OF HIGHRISE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3043	19041-20001-43839	7874 N LARAMIE AVE	91306	3	189B113  1369	2107011110	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM			PC Approved	10/30/2019 12:00:00 AM	ADDRESS	34.21385	-118.57312	10-30-2019 Changes to an approved set of plan, Changes include recalculate conductor ampacity.Plan check only, Permit covered under Master application: 19041-90000-43839Fees $63.49 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3044	18041-10000-03922	11910 W FOOTHILL BLVD	91342	7	210B165   124	2532012040	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Pacoima		1041.08	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.27508	-118.39603	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3045	13041-10001-21489	5837-5841 W SUNSET BLVD UNITS 1-79	90028	13	147A191    55	5545011023	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			01/28/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	34.09822	-118.3171	Supplemental PC: Adding outdoor lightings.<<<PLAN CHECK FOR POWER AND ENERGY. 79 UNIT APARTMENT COMMERCIAL. LOCATED IN CRA AREA. 3 LEVEL BELOW GRADE WITH 5 LEVEL TOTAL. 3 SERVICES. 75000 SQFT. VARIANCE TO SEPERATE FIRE ALARM SUBMITTED.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3046	17041-10000-03059	21773 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.16857	-118.60232	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1385 SQ. FT. 16016-10000-29085	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3047	13041-10000-36150	16656 W GLEDHILL ST	91343	12	198B137   169	2687015006	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.24211	-118.49571	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 200A MAIN IN A 2-STORY HOUSE. non-standard plan. SYSTEM SIZE IS 7 kW DC. (28)power  optimizers:Solaredge Op250-LV-AH4SM-2NA-Z   (28)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3048	16041-20002-20180	7435 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	34.20582	-118.48615	[[[4/27/17 CHANGES TO APPROVED SET. DELTA 1 PLANCHECK ONLY CHANGES. ADJUSTING LED WATTAGES]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3049	14041-20000-30143	523 W 6TH ST suite 444	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	Plan check for energy only. TI to office on 4th floor of existing high rise office building. Suite 444. New lighting only. 2,986sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3050	14041-10000-34414	759 N SPRING ST	90012		133-5A215  38	5408027005							Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	PIN	34.06161992	-118.23745547	Facade lighting for (E) 3-story commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3051	15041-10001-25787	8100 N WOODLEY AVE	91406	6	189B141    22	2206005012	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.21787	-118.48348	02/11/2016 Changes to an approved set of plans. Changes have been made to address corrections made by the inspector. Changes have been clouded and marked as Delta 3, 6, and 13.*****Previous Work Description*****NEW MOTORS FOR PROCESS EQUIPMENT AT INDUSTRIAL FACILITY.  PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3052	12041-10000-16991	3939 S CRENSHAW BLVD	90008	8	117B185  1015	5032002058	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.01358	-118.33646	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR CHANGE OF USE FROM RETAIL TO RESTAURANT. LESS THAN 100 OCCUPANTS. LESS THAN 400A. CHIPOTLE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3053	14041-10000-17236	12300 W WILSHIRE BLVD 2nd core	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.04245	-118.46922	PLANCHECK FOR T24 ENERG.Y Remodel of south 2nd floor corridor. 635 SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 14041-90000-16856.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3054	10041-20000-17430	11540 N SEPULVEDA BLVD	91345	7	213B145     9	2664006***	A2-1, RE20-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM			PC Info Complete	09/02/2010 12:00:00 AM	ADDRESS	34.27973	-118.4687	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR INTERIOR REMODEL. ABANDON THIS APPLICATION. NEW APPLICATION #10041-20000-20464	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3055	19041-10000-18183	3420 N EAGLE ROCK BLVD A-C	90065	1	153A215    97	5457022020	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.1145	-118.23591	PLAN CHECK FOR TITLE 24 ONLY PLAN REVISION TO DIVIDE SPACE INTO THREE OFFICES. TOTAL EFFECTED AREA 6368 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3056	17041-10000-20637	5901 W CENTURY BLVD	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Issued	06/22/2017 12:00:00 AM	ADDRESS	33.94572	-118.38685	Title 24 plan check.  Install reversed illuminated stainless steel channel sign on canopy of existing commercial building.       Building permit #17048-10000-01654	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3057	10041-10000-06362	4570 N GRIFFIN AVE	90031	1	147A227    10	5303024003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco, Historic Highland Park	YES	1993.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	06/10/2010 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	ADDRESS	34.09568	-118.2017	INSTALLATION OF 266.5 KW (DC) OF PHOTOVOLTAIC SYSTEM ON THE GROUND	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3058	14041-10000-12576	8147 N LANKERSHIM BLVD	91605	6	192B169   635	2310007025	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.21925	-118.38904	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 22555 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3059	16041-30000-22629	800 W WILSHIRE BLVD	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	34.0493	-118.25841	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 2310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3060	15041-10000-23886	8590 W PICO BLVD 1-36	90035	5	129B173    75	4303035074	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.05344	-118.37821	7-STORIES PLUS SUBTERRNEAN PARKING MIXED USE BUILDING-36 APTS AND RETAIL UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3061	17041-10000-12133	15005 W NORTHWIND LANE	91343	7	198B145   463	2651001***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.23893	-118.45907	PV.INSTALATION OF A NEW 5600 W DC ROF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (20) MODULES: CANADIAN SOLAR CS6K-280M, 280W(1) INVERTER: SOLAR EDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3062	17041-10000-36855	944 E PICO BLVD UNIT 1	90021	14	123A211   265	5132018034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.03051	-118.24925	REPLACEINDOOR & OUTDOOR HID EXISTING FIXURE WITH NEW LED FIXURE - TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3063	13041-20000-25245	202 N AVENUE 64 PV2	90042	14	154-5A233 385	5493016013	[Q]C4-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.11564	-118.18062	PV2 COMMERCIAL SYSTEM. ROOF MOUNTED. TOTAL SYSTEM SIZE 4.3 KW USING 20 MODULES. USING ENPHASE MICROINVERTER M215. 2 STRINGS. 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3064	14041-10000-07484	6321 W HOLLYWOOD BLVD	90028	13	148-5A187 150	5546004013	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.10178	-118.32754	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR A PROJECTION ROOM ADDITION IN A THEATRE.  PLANCHECK ONLY. PERMIT UNDER SUPPLEMENTAL 14041-10001-07484.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3065	12041-10000-11157	700 W WORLD WAY TERMINAL 7-SPACE 7J	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	PLAN CHECK POWER AND ENERGY FOR KLATCH COFFEE RESTAURANT. SPACE 7J.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3066	11041-20000-26629	19202 W KESWICK ST	91335	3	186B121    28	2104012049	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2011 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	34.21002	-118.55149	New 9.8 KW roof mounted PV system for single family residence.  Applicant is using the M215 microinverter.  A variance has been filed to use the microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3067	18041-10000-26784	16824 W CALLE MONTECITO	90272	11	138B121     9	4431038050	(Q)RD3-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.07826	-118.54925	PC FOR ROOF MOUNTED PV ON SLD. SCOPE INCLUDES 2 CENTERAL INVERTERS AND 27 MODULES AND NEW LOAD CENTER. SYSTEM SIZE 9.0 KWAC/ 8.78KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3068	19041-20001-42473	16833 W NORDHOFF ST	91343	12	198B133   613	2687005006	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.2359	-118.49929	Revisions to approved set of plans.  Electrical equipment rating/interconnection detail changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3069	12041-20001-25992	11239 W VENTURA BLVD	91604	2	162B173   294	2366035036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	ADDRESS	34.14181	-118.37523	"(((SUPP APPLICATION FOR PLAN CHECK FOR LOCATION OF SWITCHES. SALES FLOOR CONTAINS SWITCH BANK. INDIVIDUAL ROOMS CONTAIN MULTILEVEL SWITCHING AS SHOWN ON SUPPLENTEL SET. ))))T. I. / REMODEL TO (E) RETAIL.  Load is less than 400 amps per applicant.  Plan check only for Energy, with Emergency lighting.  Panel ""MDP"" is existing and load is 384.6 amps per plan."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3070	16041-10000-32617	1601 E OLYMPIC BLVD # 215	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Issued	09/14/2016 12:00:00 AM	ADDRESS	34.02923	-118.24056	TITLE 24 FOR INTERIOR OF EXISTING LOWRISE BUILDING.TOTAL SQ. FT. 16200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3071	12041-10000-26542	5900 W WILSHIRE BLVD 21ST-FLOOR	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM			PC Approved	11/05/2012 12:00:00 AM	ADDRESS	34.06237	-118.35809	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING 21ST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3072	19041-10000-30563	21829 W MICHALE ST	91304	3	192B105    39	2779029009	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.22655	-118.60389	PV1, new rooftop mounted system, system size is 4.380KWdc/3KWac. Scope of work is 12 panels  ( Hyundai HIS-S365Ri) with optimzers (SE-P400), leadng to a central inverter (SE3000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3073	16041-20000-34957	10877 W WILSHIRE BLVD Suite 1700	90024	5	132B153   297	4360003029	[Q]C4-3-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Issued	10/04/2016 12:00:00 AM	ADDRESS	34.05934	-118.44254	Plan check for energy only. TI to existing office suite 1700 in high rise office building. New lighting (incl. emergency) and receptacles. 12,891sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3074	15041-10001-18339	1406 S BONNIE BRAE ST	90006	1	127-5A201 160	5135006002	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.0441	-118.28101	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1 INSTALL 5.886 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR327NE(1)INVERTER: POWER ONE PVI -5000-OUTD>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3075	18041-20001-06317	11759 W SAN VICENTE BLVD	90049	11	129B145    16	4401017007	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.05337	-118.46794	08/17/2018 Changes to an approved set of plan, changes include revised lighting for new storage room added, refeed building 11759 San Vicente from 11757 San Vicente. All Changes has been clouded as delta 3 only. Plan check only, permit covered under Master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3076	15041-10000-15867	2624 W SUNSET BLVD	90026	13	141A205   236	5402013011	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM			PC Info Complete	05/27/2015 12:00:00 AM	ADDRESS	34.0803	-118.2704	TI-24 TO AN (E) OFFICE BUILDING. ADDING NEW LIGHTS AND CONTROLS AND TWO NEW PANELS. NEWLY CONNECTED LOAD IS LESS 400 AMPS. PC FOR ENERGY AND EMERGENCY LIGHTING ONLY.TOTAL SQ. FT. 4757 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3077	12041-10000-10317	356 S WESTERN AVE # 106	90020	10	135B193   419	5503003001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM			PC Approved	05/07/2012 12:00:00 AM	ADDRESS	34.06737	-118.30892	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TI  FOR  PREPACKED  FOOD SHOP  UNIT #106	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3078	14041-20002-12038	12655 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	33.97753	-118.41457	REVISIONS TO AN APPROVED SET OF PLANS.  REMOVAL OF SMS MONITORING SYSTEM.pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #1. 1/3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3079	16041-10000-43562	3358 E OLYMPIC BLVD	90023	14	118-5A225 252	5190034023	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.01859	-118.20616	FULL PC FOR POWER AND ENERGY. CONSOLIDATING TWO  TENANT SPACES  INTO ONE TENANT SPACE. SCOPE INCLUDES ADDING ONE 600 A 120/240V,, 1 PHASE 3 WIRE SECTION AND ADDING THREE NEW PANELBOARDS. TOTAL AFFECTED AREA IS 2455 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3080	10041-10000-22650	1230 W 3RD ST 5TH Flr	90017	1	132A209    97	5152014037	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.057	-118.259	TI IN AN EXISTING OFFICE AREA ON THE 5TH FLOOR FOR RELOCATING EXISTING LIGHT FIXTURES. PLAN CHECK IS FOR T-24 ENERGY CALCS.  PERMIT IS FOR NEW CIRCUITS AND COMMUNICATION OUTLETS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3081	11041-10000-01548	4565 W COLORADO BLVD BLDG. #1-1st floor	90039	4	162B201    20	5593012032	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	03/16/2011 12:00:00 AM		Permit Finaled	08/30/2011 12:00:00 AM	ADDRESS	34.14212	-118.27363	T.I. of existing building #1, half of the 1st. floor of room numbers 105-108, 135, 140, 142, 154,155, 156, 157, 158 as shown on plans.  Install general and emergency lighting.  Plan check for power and energy. (the plan was approvrd under# 07041-10000-30601 and it was expired)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3082	17041-20000-15349	201 N FIGUEROA ST 4th flr	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3083	16041-10003-29622	6600 N TOPANGA CANYON BLVD # 1096	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM			PC Approved	12/21/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR POWER ONLY FOR AN ICE CREAM SHOP. SCOPE INCLUDES NEW PANELS, AND NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3084	13041-20000-06199	1955 W SLAUSON AVE	90062	8	108B193  1312	5005018029	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Closed	11/07/2013 12:00:00 AM	PIN	33.98940747	-118.3127929	New externally illuminated sign.  Plan check for T-24.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3085	14041-10000-25015	10825 W ROSE AVE	90034	5	120B161   584	4254017034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Closed	02/06/2017 12:00:00 AM	ADDRESS	34.02537	-118.41643	PV2, INSTALL 16830 W DC ROOF-MOUNTED SOLAR ARRAY ON A APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL.(66) MODULES: CANADIAN SOLAR CS6P-255P(2) INVERTER: SMA AMERICA SB7000US-12	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3086	15041-10000-33963	1037 W M ST	90744	15	033B201   125	7415003023	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	33.78876	-118.27632	PV1, ROOF SOLAR MOUNTED SYSTEM (21) MODULES AND (1) INVERTER, TOTAL SIZE IS 4.2KW. (21) KYOCERA #KU2656ZPA(1) #PVI-4.2OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3087	16041-10000-13840	1737 N LAS PALMAS AVE 1-82	90028	13	148-5A185  43	5547010004	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.1026	-118.33639	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 6-STORY 82 UNIT MIXED USE APARTMENT BUILDING. SCOPE INCLUDES 307 FA DEVICES, 1 FA PANEL, AND 1 COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3088	15041-20000-42744	10606 N HAYVENHURST AVE	91344	12	207B137   570	2679002012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.26305	-118.49337	Plan check for a PV1 roof-mounted PV system. System size is 8.4 kWac and consists of (2) inverters, (35) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3089	17041-10000-26638	3201 S HOOVER ST #1835	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.0255	-118.28448	PC FOR FIRST TIME T.I.  (RESTAURANT USC PROJECT) FOR POWER AND ENERGY. TOTAL AFFECTED AREA 1346 SQ.FT. SCOPE INCLUDES PANELS CIRCUITS EQUIPMENT LIGHTS AND RECEPTACLES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3090	13041-20000-07661	13728 N DE FOE AVE Pv-1	91342	7	228B145   234	2603021014	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.3208	-118.47188	Plan check for PV. Microinverter system. 5.375kW total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3091	19041-10000-26104	7437 N VANTAGE AVE	91605	2	186B165   465	2307025040	(Q)RZ3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.20584	-118.39816	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 18 MODULES (SP-E19-320), 18 OPTIMIZERS (SE P400) AND 1 CENTRAL INVERTER (SE5000H-US). SYSTEM SIZE IS 5.76KWdc AND 5KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3092	14041-10000-27483	7349 W 91ST ST	90045	11	093B157    38	4119017011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/29/2014 12:00:00 AM	ADDRESS	33.95445	-118.42434	PV1, INSTALL 6.885 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (27) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE # SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3093	15041-10000-35598	245 E 61ST ST	90003	9	105B205   560	6006008036	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.98436	-118.27027	PV 1. Installation of a roof mounted solar system interconnected  with the main panel. Scope: (1) 4.2 kw Inverter,  (23) modules, (1) 125 A distribution panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3094	11041-20000-05578	300 S GRAND AVE 6th Floor	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Finaled	03/20/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to a high rise building.  Install general lighting in partial of 6th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3095	14041-20000-23804	6501 N FULTON AVE	91401	2	180B157   719	2329025017	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Apartment			08/29/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.18853	-118.42274	Replace fire damaged  600A service equipment and 5 unit panels AS IS (like-for-like). Existing 3-story apartment building.DUE TO CODE ENFORCEMENT ORDER, PERMIT TO EXPIRE WITHIN 30 DAYS FROM DATE OF ISSUANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3096	14041-20000-22236	6626 N MATILIJA AVE	91405	2	180B153   463	2238011043	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.19119	-118.43331	3.12kw PV1 roof-mounted system including: (13) Sunedison F270KYC modules and Enphase M250 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3097	18041-10000-05376	6080 W CENTER DR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	PC FOR TI-24 ENERGY ONLY  FOR  TI: RENOVATION OF GROUND FLOOR LOBBY ENTRANCE, FITNESS CENTER, OFFICE AND RETAIL SPACCES(N)  AND OUTDOORS LIGHTS IN CAMPUS STYLE. TOTAL AFFECTED AREA 10145+23210 SQ.FT (INDOOR + OUTDOOR) SCOPE INCLUDES NEW PANELS, LIGHTS EQUIPMENT AND RECEPTACLES. B#17016-10000-36283	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3098	14041-20000-27835	22252 W CRISWELL ST	91303	3	180B101   355	2139011014	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.19056	-118.61194	PV1.  Install 8.16 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3099	13041-20000-04079	12326 W RIVERSIDE DR	91607	2	168B165   537	2356034011	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.15745	-118.40171	New and existing equipment to connected to MSA as shown in the dashed line identified with specific note 2 on page E-3 of the plan.  No new lighting to be installed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3100	12041-10000-27940	3000 W 6TH ST 2ND FL	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Approved	11/20/2012 12:00:00 AM	PIN	34.06351748	-118.28745252	TENANT IMPROVEMENT IN AN EXISTING RESTAURANT IN A 2-STORIES BUILDING PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3101	13041-10000-26077	2250 S FOX HILLS DR 1-22	90064	5	129B161   138	4315017037	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			09/20/2013 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.05144	-118.4154	PLANCHECK FOR POWER AND ENERGY FOR A NEW 22 UNIT APARTMENT BUILDING. NEW 5 STORY,  36,146 SF  22 UNIT APARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3102	16041-20000-37800	10648 W MAGNOLIA BLVD	91601	2	171B177   683	2419013003	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.16473	-118.36326	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to massage parlor/tenant improvement. Total lighting area = 746 sq. ft.Note: Building permit has been pulled under 16016-20000-09671	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3103	16041-10000-11585	1039 S GRAMERCY PL	90019	10	129B189   376	5081026022	R1-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Expired	05/04/2018 12:00:00 AM	ADDRESS	34.05163	-118.31347	PV1, INSTALL NEW 5.22 KW DC ROOF-MOUNTED SOLAR ARRAY ON ASINGLE FAMILY HOME.(18) MODULES: SILEVO TRIEX U290 BLACK(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3104	15041-10000-14458	8933 N QUARTZ AVE	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.23287	-118.56489	Plan check for fire alarm system for office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3105	19041-10000-25282	3113 S QUEENSBURY DR	90064	5	123B161   342	4316005002	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.03508	-118.40764	[e-plan] PV1. PLAN CHECK FOR 7.6 KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIVIA 7.6 TL) WITH 26 MODULES(HANWHA Q-CELL SC315) WITH 2 ESS(TESLA POWER WALL) CONNETED TO AN EXISTING 200 SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3106	19041-20000-27779	1056 N TELLEM DR	90272	11	132B121   457	4419004043	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.05547	-118.54587	Plan check for PV roof mounted system, PV system size: 14.68KW DC, 13.68KW ACwith 45 PV Modules and 45 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3107	18041-10002-26790	3602 S 6TH AVE	90018	10	120B189  1229	5044027001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM			PC Approved	09/21/2018 12:00:00 AM	ADDRESS	34.02274	-118.32345	DELTA 2 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING THE LOCATION OF THE INVERTER.<<<<<<PLAN CHECK FOR ROOF MOUNTED 3.3KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(PVI-3.3-OUTD-S-US-Z-A) WITH 10 PANELS (SOLARCITY)>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3108	11041-10000-05976	7131 W SUNSET BLVD	90046	4	147B181   635	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Approved	03/25/2011 12:00:00 AM	ADDRESS	34.09815	-118.34528	TI FOR A TAKE-OUT RESTAURANT. EPC IS FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3109	17041-20000-25426	23286 W CLARENDON ST	91367	3	174B093   574	2044002050	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.16906	-118.6341	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3110	18041-10000-17287	10250 W SANTA MONICA BLVD Delta-41	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			PC Approved	05/10/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	New revision to approved landlord's plan, noted as Delta-41. Revise tenant suite number from 2320 to 2330 on Distribution board DB-ELA44. This is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3111	19041-10000-32971	8351 N NORTHGATE AVE	91304	3	192B105   694	2779043034	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Issued	08/22/2019 12:00:00 AM	ADDRESS	34.22138	-118.6042	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-25 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3112	16041-10000-02837	2627 E ALICE ST	90065	1	145-5A217  47	5453001030	RD3-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.09418	-118.22913	PV1 rooftop installation, 6 kW AC (25) SE-F270KzD, (25) P300, (1) SE-6000A-US (1) 100A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3113	18041-10001-18540	21110 W OXNARD ST	91367	3	177B105    76	2149002023	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM			PC Info Complete	01/22/2020 12:00:00 AM	ADDRESS	34.17903	-118.59355	PC only. Change to an approved set by updating the plan with new fault current, relocating and updating the load including lighting and power, service load calculation also being recalulated. All changes under delta-2 only.original plan checker, John(((FULL PC FOR POWER AND ENERGY. NEW 7 STORY HOTEL WITH ONE LEVEL SUBTERRANEAN PARKING. SCOPE INCLUDES INSTALLING A NEW 1600A 480/277V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3114	16041-10000-42747	3616 S TROUSDALE PKWY	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.01983	-118.28534	T-24, PC for energy only. Change of use in (E) basement from Dance Room to Office. No exterior work on scope of work. Total affected area is 1977 SQ. FT. B#16016-10000-26861	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3115	14041-10000-10628	430 N LECOUVREUR AVE	90744	15	030B209   873	7424005045	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	33.77548	-118.25538	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3116	18041-10000-10912	3410 N DREW ST	90065	13	156B213   305	5458026016	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.12104	-118.24126	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3117	18041-10000-22479	6100 W CENTER DR 700	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM			PC Info Complete	06/19/2018 12:00:00 AM	ADDRESS	33.97733	-118.3922	Energy plan check for an office T.I located in the 7th floor of a commercial building. Scope includes new lighting and equipment with a total T-24 area cover 10,863-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3118	15041-10002-22097	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Changes to approved set of plans . Note, changes under delta 13 only. Scope of work includes the addition of the lab panels and space. Total sq. ft. 29459. The permit fee is paid for application 15041-10002-14660	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3119	13041-20000-32479	17309 W RAYEN ST	91325	12	195B133   185	2768018006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2013 12:00:00 AM			Corrections Issued	12/13/2013 12:00:00 AM	ADDRESS	34.23232	-118.51173	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC. 48 MODULES AND 2 INVERTERS.APPLICATION WITHDRAWN DUE TO DUPLICATE RECORD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3120	13041-10001-35451												Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM				Unused application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3121	19041-10000-03636	621 W ROSECRANS AVE	90248	15	075B201    35	6132006031	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.90205	-118.28562	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 246.01KWdc / 208KWac.(672)MODULES- 365W JAM72S01-365/PR(4)INVERTER-33KW HUAWEI (1)INVERTER-36KW HUAWEI (4)INVERTER-40KW HUAWEI	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3122	16041-20000-19809	433 S WESTMORELAND AVE	90020	5	132B153   800	4324006020	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/06/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.06559	-118.28861	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 64KW INTERCONNECTED WITH MSP.Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3123	08041-10003-06267	609 S ST PAUL AVE	90017	1	130-5A207  24	5143025002	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			09/09/2011 12:00:00 AM	09/20/2011 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.05337	-118.26134	REVISIONS TO a previously approved set of plans.  No permit was ever issued for the original set of approved plans.  ADDITION OF 6 PUMPS , TWO AC UNITS AND SOME FEEDERS CHANGE FROM CU TO AL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3124	17041-10000-33925	700 S FLOWER ST 575	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	TENANT IMPROVEMENT:WORK CONSISTS OF NEW OFFICES, LIGHTING AND MILLWORK, NON STRUCTURAL PARTITIONS,  2751 SF. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3125	14041-10001-02362	2806 N GLENDOWER AVE	90027	4	153B197   127	5588011007	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.11598	-118.2964	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 3.98 KW DC roof-mounted solar array on a three story house, interconnect with existing service panel. (1)Transformerless inverter: POWER-ONE AURORA PVI-3.0-OUTD-S-US(15) Modules: SUNIVA OPT265-60-4-1B0.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3126	14041-20000-01285	616 S ARDEN BLVD	90005	4	135B189   891	5505021009	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.0631	-118.32563	New PV system with 3.6kw inverter with 8 panels added to an existing PV System.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3127	10041-10000-09167	603 S CENTRAL AVE	90021	14	126A215   219	5147031025	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM			PC Approved	05/25/2010 12:00:00 AM	ADDRESS	34.03895	-118.2403	T.I. to existing building in the 2nd floor.  Install general and emergency lighting.  Plan check for Title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3128	14041-20000-03543	733 E 55TH ST	90011	9	108B205   528	5103010022	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	33.99259	-118.26197	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3129	18041-10000-12796	12202 W VENTURA BLVD	91604	2	162B165   218	2369004038	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.14304	-118.39861	PLANCHECK FOR T24 ENERGY. Tenant improvement to (E) retail space . NEWLY CONNECTED LOAD < 400 AMPS. INDOOR+ OUTDOOR+ SIGN LIGHTING. 2860 SQFT.BUILDING PERMIT # 18016-10000-00971	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3130	14041-20000-13604	10201 N ETON AVE	91311	12	204B105   454	2747011047	R2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.25559	-118.59525	2.592 PV1 roof-mounted  Micro inverter system with (12) SW 250 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3131	17041-10000-09762	11511 W VENTURA BLVD	91604	2	162B169   538	2368023034	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.13986	-118.38205	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 13400 SQ. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3132	16041-10001-33809	1936 E 1ST ST	90033	14	129A221   303	5174016057	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	34.04587	-118.21637	RENOVATION OF AREAS INSIDE OSHPD 3 CLINIC FOR DIALYSIS. CHECKING FOR OSHPD 3 FOR 2 ROOMS FOR PATIENT IN HOME TRAINING. PERMIT ALREADY ISSUED UNDER MASTER APPLICATION. PLAN CHECK FOR ENERGY COMPLETED UNDER APPLICATION: 16041-30000-24482THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3133	15041-10000-27802	8480 W 3RD ST	90048	5	138B173   779	5511032029	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.07317	-118.37579	CHANGE OF USE FROM RETAIL TO RESTAURANT INTERIOR NON BEARING PARTITIONS. pc for power and energy. A - occupancy place of assembly. PC in accordance to art. 518.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3134	19041-10000-40781	11338 W STRATHERN ST	91352	6	189B173   244	2314014062	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.21555	-118.37826	Plan check for a PV1 8.175 KW AC roofmounted system. Scope includes (1) load center, (25) microinvetrter and module interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3135	18041-10000-18733	5634 N FIGUEROA ST	90042	1	151-5A229 278	5468032018	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.10941	-118.19281	PLAN CHECK FOR T-24 ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES AND PANELS TO AN EXISTING OFFICE SPACE. THERE IS NO CHANGE OF USE, TOTAL SQ. FT. 6735.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3136	15041-20002-16804	9301 N TAMPA AVE #25	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM			PC Approved	10/07/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	10/7/15 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. CHANGES TO FIXTURE TYPE A. 08/27/2015 Changes to an approved set of plans. Changes include lighting fixture locations and new lights in the restroom and dispensary. All changes have been reflected on the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only for Vanity District Salon(Chnage of use from Retail to hair salon). Total area: 942 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3137	15041-10000-04094	6838 W HOLLYWOOD BLVD	90028	13	147B181   190	5548006016	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.10137	-118.33998	Plan check for power. Project site is a theater (El Capitan Theater). Project includes the installation of a new 150-amp rated panel, associated loads, and (2) 14 kWac A/C units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3138	17041-10000-17269	11009 W BURBANK BLVD #121	91601	2	174B173   864	2337025017	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/30/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.17232	-118.37072	Title 24 plan check.  T.I. to massage parlor.  New lighting and receptacles.  Total area = 812 sq. ft.       Building permit 16016-10000-27199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3139	18041-10000-11902	3946 E YORK BLVD	90065	14	157-5A217 291	5459027018	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.12492	-118.23107	PV1. ROOFMOUNTED SOLAR SYSTEM. POWER OPTOMIZERS. SYSTEM SIZE: 8.250 KW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3140	15041-10000-40673	2300 N EL CONTENTO DR	90068	4	153A189   434	5585029042	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM			PC Info Complete	06/03/2016 12:00:00 AM	ADDRESS	34.11241	-118.32603	PC FOR PWER. NEW SINGLE FAMILY  4 BED/3BATH/4 CAR GARAGE/BASEMENT/2ND UNIT AND DRIVEWAY. THE SOLAR PART SHOULD BE DONE UNDER SEPRATE PERMIT.B # 15010-10000-04097	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3141	17041-20001-22495	10036 N SUNNY BRAE AVE	91311	12	204B109   416	2741024027	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM			PC Approved	07/21/2017 12:00:00 AM	ADDRESS	34.25273	-118.58081	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3142	18041-10000-06178	10530 W GARWOOD PL	90024	5	135B153   139	4360020012	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.06814	-118.43452	PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL 5.8KVA) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL(200A). EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3143	18041-20000-16807	5832 N TUJUNGA AVE	91601	2	174B173   160	2337014005	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1242.03	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.17687	-118.37885	new fire alarm system 35 devices + facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3144	18041-20000-29745	826 N WATERLOO ST	90026	13	139-5A205 266	5402027009	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1957.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.07627	-118.26772	pv1install roof mounted pv system sized 5.2 KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3145	17041-20000-42664	10921 W CHANDLER BLVD	91601	2	171B173    74	2416002006	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM			Reviewed by Supervisor	12/08/2017 12:00:00 AM	ADDRESS	34.16876	-118.3688	new commercial (office) building 600 amp service.  plan check for power and energy.BUILDING PERMIT # 17010-20000-03602	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3146	15041-10000-42519	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Expired	04/06/2020 12:00:00 AM	ADDRESS	34.07196	-118.24719	PC FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES THE REMOVAL AND ADDITION OF PANELS THROUGHOUT SECTIONS OF THE DODGER STADIUM AND NEW TRANSFORMERS. PANELS INCLUDE A NEW 3000 AMP SWITCH GEAR AND A NEW 1000 AMP DISTRIBUTION BOARD. NEW LIGHTING ON THE CORRIDOR, STAIRWAY AND ELECTRICAL ROOMS. TOTAL SQ. FT. 11,757	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3147	13041-10000-30416	19620 W LOS ALIMOS ST	91326	12	207B117    22	2708011026	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	PIN	34.26768154	-118.56101581	PV1 15KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(3) inverters: {SOLAREDGE SE5000A-US, SOLAREDGE SE5000A-US, SOLAREDGE SE3000A-US}]. [(60)modules: {Renesola {JC250M-24/BB}}]     'Expedited plan check per applicant request' Senate Bill No.1222 Fee cap reached on original application, thus fee is $0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3148	19041-10000-17000	18310 W OXNARD ST	91356	3	177B125   690	2157002131	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	06/13/2019 12:00:00 AM	ADDRESS	34.18003	-118.53125	PLAN CHECK FOR A ROOF MOUNTED 333KVA PV2 SYSTEM CONSISTING OF 4 INVERTERS(3-SE99.9K-US & 1-SE33.3K-US) WITH 1092 MODULES USING 546 OPTIMIZERS(P850)PLANS TO BE ASSIGNED TO EDWIN OR JOHNPERMIT 19041-10000-16998PLAN CHECK FOR POWER FOR SERVICE EQUIPMENT FOR FEED-IN TARIFF PV2 SYSTEM UNDER PERMIT LISTED BELOW RATED AT 1200A 120/208V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3149	18041-10000-40919	518 N CHAUTAUQUA BLVD	90272	11	123B129    80	4411016013	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.03649	-118.51883	NEW ROOF MOUNTED 10.65KW PV SYSTEM WITH 30 PV MODULES AND (TWO 17.1 KWH FOR A TOTAL OF 34.2 KWH BATTERY STORAGE UNITS WITH FUSED DISCONNECTS) ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3150	15041-10000-08893	7322 N LOMA VERDE AVE	91303	3	186B109   868	2112015005	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.20353	-118.58945	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.6KW INTERCONNECTED WITH MSP.(((((APPLICANT HAS NO CREDIT MEANS TO PAY FOR ONLINE PERMITTING)))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3151	14041-10000-33820	1150 N ORLON AVE	90272	11	132B125    51	4420007005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Expired	03/08/2017 12:00:00 AM	ADDRESS	34.05465	-118.53238	INSTALL 6.63 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(26) MODULES: YINGLY YL255P-29B(1) INVERTER: ABB PVI-6000-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3152	16041-10001-34621	740 S WESTERN AVE #117	90005	10	132B193   501	5093007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM			PC Approved	11/03/2016 12:00:00 AM	ADDRESS	34.05845	-118.30891	REVISION TO PREVIUSLY APPROVED PLAN, CAHNGES UNDER DELTA 1.   CHANGING OF LIGHTING LAYOUT. T24 PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER 16041-10000-37082 & 16041-10003-37082	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3153	10041-10003-11574	7045 W LANEWOOD AVE	90028	13	147B181   419	5548012009	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			08/21/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.09933	-118.34304	Modification is only to change from a time clock to a photocell for auto-shut-off for outdoor lighting only and remove tc override switches.  Plan Check Only.          <<<<<Plan check power and energy for new 4-story 43 unit apartment building. Modification to seperate fire alarm system has been filed.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3154	11041-20000-03959	15986 W ALCIMA AVE	90272	11	129B125   308	4420003020	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.05076	-118.53501	PLAN CHECK FOR 2 STORY SINGLE FAMILY DWELLING WITH 600A SERVICE ELECTRICAL SYSTEM. PLAN CHECK UNDER NEC2005/CEC2007.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3155	16041-20000-44597	8505 W FOOTHILL BLVD	91040	7	207B189  1077	2555033031	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.25989	-118.31823	(N) Car wash addition to existing gas station. Upgrading service to 800A. New panels and distribution equipment for car wash.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3156	14041-20001-09925	17500 W BURBANK BLVD	91316	5	174B129   855	2254037019	RA-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	34.17213	-118.51506	Expedited plan check per applicant request.  (((PV2.  Install 92.2 kW roof-mounted PV system on commercial property (church).  Both transformer-ed and transformer-less inverters.  (318) modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3157	16041-10000-06803	7314 S AVALON BLVD BODY-SHOP	90001	9	102B205  1099	6023008004	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	PIN	33.97335974	-118.26484803	T-24, RESTORE FIRE DAMAGED BUILDING, BODY SHOP. SCOPE OF WORK INCLUDES NEW EQUIPMENT, LIGHTING AND RECEPTACLES. NO SPRAY BOOTH IN SCOPE OF WORK. TOTAL SQ. 3755.Permits pulled under application numbers:    16041-10000-16404     16041-10001-16404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3158	11041-20000-13786	16055 W VENTURA BLVD	91436	5	168B141   524	2261022023	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM			PC Approved	07/13/2011 12:00:00 AM	ADDRESS	34.15653	-118.4831	TI IN AN EXISTING BANK. EPC IS FOR T24 ENERGY (GENERAL LIGHTING/EMERGENCY).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3159	18041-10000-47366	10965 W WELLWORTH AVE 1-75	90024	5	132B153   683	4324003022	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			12/13/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Issued	01/07/2019 12:00:00 AM	ADDRESS	34.05655	-118.44524	Energy plan check for cooridors, gym and offices T.I in a 4-story apartment building. Scope includes new light and equipment with a total area of 10,063 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3160	14041-10000-28477	1043 S KINGSLEY DR	90006	10	129B193   528	5080025009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.05133	-118.30329	PV2, 21.1 Kw roof-mounted system including (4)Delta Solivia 5.2TL  inverters , and (88) LDK 280p-24 modules. Clearances have been cleared on building permit#: 14016-10000-20948	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3161	10041-10000-20959	523 E ROSE AVE	90291	11	111B141   296	4240005003	C4-1	West Los Angeles	Venice	Grass Roots Venice		2733.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	33.99859	-118.47333	CHANGE OF USE FROM A SINGLE FAMILY DWELLING TO A RESTAURANT WITH RETAIL SPACE AND AN ACCESSORY OFFICE. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3162	19041-10000-08444	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.07417	-118.26931	$0 fee per AB1414. Plan check for a 408KW AC / 452KW DC roofmounted PV2 system, located on the top of a commerical building and (2) carport. Scope includes (1222) modules, (90) strings, (18) inverter interconnectring through the load centers to back feed the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3163	11041-20000-16196	1254 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/02/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29325	New 3.23 Kw PV System for Apartment Bldg #1254	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3164	18041-10000-18137	2714 S FORRESTER DR	90064	5	126B165   197	4308006019	R1V2-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.04379	-118.40398	INSTALL A 40.5 KWH BATTERY STORAGE SYSTEM TO AN EXISTING SOLAR SYSTEM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3165	15041-20000-43222	7407 N LUBAO AVE	91306	3	186B113   565	2115005002	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.20498	-118.56815	Addition to an (E) rooftop solar system of 20 modules, 3.8kW ACAdd:(14) KU2656ZPA(1) PVI-3.0-OUTD-S-US(1) Load Center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3166	16041-20000-26899	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.32381	-118.49103	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,341 sq. ft.Note: Building application has been generated under 16014-20000-03627	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3167	14041-20000-01732	7127 N CANOGA AVE	91303	3	183B105   302	2111028032	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.19999	-118.59788	Change to lighting in an existing commercial space, not a first time tenant.  Office with workshop in the back, not a first time tenant.  Load is less than 400 amps.  PLAN CHECK for T-24 only.  No emergency lighting required per the applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3168	19041-10000-06942	15860 W OLDEN ST	91342	7	225B141   153	2501002022	(Q)P-1, M1-1, P-1, [Q]M1-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.31311	-118.47601	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3169	11041-10000-10865	12744 N SAN FERNANDO ROAD NORTHEAST ROADWAY	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM			Corrections Issued	07/01/2011 12:00:00 AM				Install one new panel and various electrical equipment for clean room facility.  The total added load exceeds 400 amperes.  No lighting is included on the plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3170	16041-10003-42610	695 S SANTA FE AVE	90021	14	124-5A2171363	5164019026	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.03508	-118.23039	CHANGES TO AN APPROVED SET OF PLANS. CHANGES ARE UNDER BULLETIN 17 AND DELTA S &  CHANGES INCLUDE REMOVING OUTDOOR LIGHTING FIXTURES, REVISING LIGHTING FLOOR PLANS, AND REVISING PANEL SCHEDULES. NOTE: PERMIT IS PAID UNDER PCIS 16041-10000-42610	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3171	18041-20000-29352	20740 BUR OAK CIR	91326	12	219B109   360	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	PIN	34.29414492	-118.58745412	Plan  check for PV roof mounted system, system size: 2.68kW with 8 AC modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3172	15041-10000-30312	9410 S BROADWAY	90003	8	094-5A203 463	6053006926	RD1.5-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM			Reviewed by Supervisor	09/21/2015 12:00:00 AM	ADDRESS	33.95056	-118.27797	CORE AND SHELL PC FOR POWER AND ENERGY ON A NEW COMMERICIAL RETAIL  BUILDING. SCOPE INCLUDES OUTDOOR LIGHTING AND INSTALLATION OF THE SWITCH GEAR. NO LOAD CONNECTED TO PANEL L 2, L3 AND L4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3173	18041-10000-15043	18700 W VENTURA BLVD UNIT# 110	91356	3	174B121   811	2161026005	(Q)C2-1VL, C2-1VL, R1V2	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.17045	-118.54081	Energy plan check for a commercial T.I located on the ground floor of a 2-story commerical building. Scope includes new lighting and equipment. Total area is 3,951-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3174	13041-10000-00318	11525 N HUNNEWELL AVE	91342	7	213B165   684	2531015052	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.27887	-118.39572	photovoltaic system for single story family dwelling. central inverter inverter - sunpower spr - 5000mpannel sunpower spr - 327ne-wht-d18 pannelspv.1 roof mounted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3175	13041-10000-05505	6330 W SAN VICENTE BLVD 3RD FLOOR	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM			PC Info Complete	03/04/2013 12:00:00 AM	ADDRESS	34.06116	-118.36804	13041-10000-05505T24 LIGHTING PLAN CHECK FOR 3 STORY LOW RISE OFFICE SPACE FOR THE CORRIDOOR ON THE 3RD FLOOR. 1016 SQRFT. EXPRESS PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3176	13041-10000-24499	19330 W PLUMMER ST	91324	12	198B117    73	2761037001	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.2426	-118.55515	NEW FIRE ALARM SYSTEM , CENTRAL STATION MONITORING TO BE INSTALLED IN ROSS. 1 PANEL, 32 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3177	18041-20000-12497	22622 W VANOWEN ST	91307	12	180B097    33	2038020063	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.19355	-118.61959	Plan check for Title 24 only. Project site is  Career Center in a high school. Project scope is a tenant improvement. Total lighting area = 2,100 sq. ft.Note: Building application has been generated under 18016-20000-10526	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3178	15041-10000-01067	12542 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	33.97819	-118.41198	Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps. Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3179	19041-20001-31960	8748 N REMMET AVE	91304	3	195B105   175	2779041033	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.22962	-118.60011	Expedited plan check fee. PV3.  Install 22.57 kW DC grid tied PV system on carport.  (74) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3180	19041-20000-13758	4760 W MELROSE AVE	90029	13	141B193   588	5521006039	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.20	Electrical	Electrical	Apartment			04/23/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	08/26/2021 12:00:00 AM	ADDRESS	34.08328	-118.3039	New 5-story 39-unit mixed-use building.  1200A 208Y/120V 3ph-4w service.  Building permit under 19010-10000-01240.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3181	17041-10000-22830	2181 W WARMOUTH ST	90732	15	009B189   501	7563037056	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.71969	-118.32448	PLAN CHECK FOR BATTERY BACK UP SYSTEM ON SINGLE FAMILY DWELLING WITH EXISTING PV SYSTEM. TESLA POWERWALL 2(13.5KWH)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3182	15041-10001-24070	1500 W PACIFIC COAST HWY Bldg J	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION OF 41 DEVICES AND 1 POWER SUPPLIES, FOR FUTURE ADA REQUIREMENT.  (((NEW FA SYSTEM FOR A New 3-story, 15 unit apartment with garage, 43 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3183	17041-10000-42783	443 S SAN PEDRO ST	90013	14	127-5A213 105	5148011018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	03/25/2021 12:00:00 AM	ADDRESS	34.04477	-118.24374	PC FOR SERVICE UPGRADE FOR EXISTING COMM. BUILDING WITH DWELLING UNITS. (POWER ONLY)SERVICE SIZE RATED AT 2000A 120/208VSCOPE INCLUDES NEW SERVICE GEAR AND 2 RESIDINTIAL DIST. BOARDS.ALL DWELING UNITS PANELS TO BE UNDER A SEPERATE PERMIT AND ARE FOR REFERENCE ONLY!BUILDING APP#17016-10000-32478	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3184	19041-20000-32051	3921 N LAUREL CANYON BLVD	91604	2	162B165   437	2369013019	R1-1-RFA-RIO, R1-1VL-RFA-RIO, [Q]RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.14179	-118.39477	New corridor lighting and power for 2-level addition to (E) 2-story school.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3185	15041-10001-34966	733 E 116TH ST	90059	15	084B205   108	6072008007	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM			Not Ready to Issue	03/03/2016 12:00:00 AM	ADDRESS	33.92928	-118.26095	Supplemental PC  to 15041-70000-34966. <<<Install a roof mounted photovoltaic system to existing single family dwelling (2.295      KW)Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3186	14041-20000-28849	18725 W SHERMAN WAY	91335	3	183B121    99	2118026018	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Issued	10/28/2014 12:00:00 AM	ADDRESS	34.20128	-118.54148	INSTALL NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3187	16041-20002-44973	3376 S MOTOR AVE	90034	5	120B161   169	4314023013	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.0281	-118.40963	Revisions to approved set of plans plus plan review for lost approved plan set.  Change of module brand.  (((Plan check for installation of solar pv system, roof-mounted on a commercial building.Interconnect with a 400A MSP. 10kW ungrounded system. (36) 280W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3188	14041-20000-34353	626 W WILSHIRE BLVD	90017	14	129A209    83	5144006025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.04843	-118.25695	Install new temporary 1200A equipment for temporary emergency generatory of the existing high rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3189	10041-20000-13320	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.2392	-118.55379	relocate 4 lights remove track lighting and add 9 lights energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3190	16041-10000-06852	514 S SPRING ST	90013	14	129A211   153	5149036907	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.04695	-118.24984	NEW FIRE ALARM SYSTEM FOR, 5-STORY  LATINO THEATER. 312 FA DEVICES. ONE FA PANEL, ONE ANNONCIATOR AND 4 CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3191	18041-20000-36226	15367 W VALLEY VISTA BLVD	91403	5	166-5A145 166	2283021016	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Issued	09/21/2018 12:00:00 AM	ADDRESS	34.14935	-118.46958	Plan check for PV roof mounted system, system size: 5.8kW with 20 modules and 20 microinverters. PV Standard is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3192	13041-10001-08667	120 S LOS ANGELES ST	90012	14	130-5A213  98	5161016027	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.05092	-118.24262	CLIENT DELETED ONE FIXTURE TYPE AND ADDED ANOTHER TYPE.  TOTAL TITLE 24 CALCULATIONS REDONE.  ORIGINAL WORK DESCRIPTION:  T24 FOR NON HIGH RISE HOTEL. REPLACING EXISTING LIGHTS USING EXISTING CIRCUITS. 1000 SQ. FT. ELECTRICAL PERMIT WILL BE PULLED AT ELECTRICAL COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3193	10041-20000-21951	12626 W RIVERSIDE DR #409	91604	4	168B161   471	2357032009	PB-1, QC2-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM			Reviewed by Supervisor	12/14/2010 12:00:00 AM	PIN	34.15730764	-118.4080743	Plan check power and energy for change of use from office to medical office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3194	09041-10001-18636	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	02/24/2010 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	34.08363	-118.32191	Revision to approved plans.  Change to ckts, type of devices, and 84 additional devices.  This is a new fire alarm system, 3 stories and 1 mez. one new panel and 313 devices was permited.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3195	14041-10001-02384	10326 N SHERMAN GROVE AVE	91040	7	204B189   449	2560018019	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Apartment			01/28/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.25687	-118.32002	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 11 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel. (2)Transformerless inverters: SOLAREDGE SE6000A-US-ZB-U & SOLAREDGED SE5000A-US(44) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3196	14041-20001-32458	5627 N ALLOTT AVE	91401	2	174B157   489	2343011013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.17292	-118.42811	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2 KW INTERCONNECTED WITH MAIN SERVICE PANNEL. (38) SUNPOWER 327W MODULE(2) POWERONE PVI INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3197	17041-10000-21490	3700 S LA BREA AVE	90016	10	117B177  1129	5046038025	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM			PC Info Complete	08/28/2017 12:00:00 AM	ADDRESS	34.01929	-118.35537	PC FOR T24 ENERGY ONLY RETAIL UPGRADES. NEW LIGHTING AND DISPLAY LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3198	13041-20000-35021	1183 N VERMONT AVE A-D	90029	13	144B197   367	5540019019	RD1.5-1XL, [Q]C2-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.09304	-118.29194	PC FOR T24 ENERGY ONLY. PC FOR UNITS A-D. FIRE DAMAGE RESTORATION. NEW LIGHTING. ((WORK DON EIN UNITS A-D	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3199	17041-10001-45739	18625 W SUPERIOR ST	91324	12	201B121   469	2763033021	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.24636	-118.5392	EXPIDITE  PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 13.2KWDC/ 11.4KWACSCOPE INCLUDES 44 MODULES WITH OPTIMIZERS AND SINGLE CENTRAL INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3200	12041-10000-15044	690 S WILSHIRE PL	90005	10	132B197   173	5077014037	C2-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Expired	01/21/2015 12:00:00 AM	ADDRESS	34.06019	-118.28764	New 35KW roof mounted photovoltaic system for a commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3201	13041-10000-34423	5500 W SUNSET BLVD	90028	13	147A193   108	5544029011	[Q]C2-2D	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Closed	10/02/2020 12:00:00 AM	ADDRESS	34.09793	-118.30958	INSTALLATION OF SPRINKLER MONITORING SYSTEM W/ OCCUPANT NOTIFICATION IN SINGLE STORY BUILDING ('TARGET'), WITH PARKING & INDIVIDUAL TENANT SPACES. OCCUPANT TYPE-M, FULLY SPRINKLERED PROTECTION. 447 TOTAL DEVICES, WITH 2 PANELS(1 FACP, 1 CONTROL PANEL) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3202	15041-20000-35251	13571 W VAUGHN ST Building B	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.27758	-118.42846	TI to an existing warehouse build. PC for Energy only. ((((((Note: Applicant reduce area sq. ft from 65,250sq, ft to 8400 sq. ft  condition office area. New Total area: 8,400 sqft. )))))))Total area 65,250sq. ft(Prior submittal)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3203	14041-20000-16379	19331 W BUSINESS CENTER DR 101	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM			Reviewed by Supervisor	06/24/2014 12:00:00 AM	ADDRESS	34.23118	-118.55466	TI  for medical clinic including tittle 24, power and sub panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3204	13041-10000-34758	1537 S PONTIUS AVE	90025	5	129B149   110	4324018008	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.04903	-118.44645	Remove HID light fixtures and replace with new fluorescent fixtures in existing office space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3205	14041-20001-08975	8542 N PONCE AVE	91304	12	192B097    38	2004013029	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.22591	-118.62126	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW. USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3206	19041-20000-12285	23317 W BALMORAL LANE	91307	12	183B093   252	2028018016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.19842	-118.63511	Plan check for PV roof mounted system, system size: 4.0KW AC SMA Sunny Boy 4000TL-US with 18 PV moduls connected to 200A Main panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3207	15041-10000-11202	22831 S FRAMPTON AVE	90501	15	045B197    50	7347018031	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	33.81817	-118.2997	RETROFIT OF 21 EXISTING LIGHTS TO LED WITH RETROFITS KITS. TITLE 24,  PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3208	17041-10000-05825	940 S STANFORD AVE	90021	14	124-5A211 272	5132004032	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.03382	-118.24846	PC for outdoor title 24. Removing HID fixtures and replacing them with new LED ones. Area: 20,050.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3209	18041-10000-33498	10250 W SANTA MONICA BLVD #1985	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK FOR FIRST TIME TENANT FOR JOHN JOHN - SPACE 1985TOTAL AFFECTED AREA = 3979 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3210	17041-20001-20007	12035 W WILSHIRE BLVD	90025	11	126B145    25	4265016043	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.04541	-118.46622	CHANGES TO APPROVED SET DELTA 2 ONLY. ADD AND RELOCATION OF FIRE ALARM DEVICES.<<<Installation of fire alarm system in new 113,834 sq. ft. apartment building with 5 floors of residential over 3 floors of underground parking.  Total system size = 308 devices + 6 RPS + 1 FACP>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3211	15041-10001-22105	1806 S CARMONA AVE	90019	10	126B177   903	5064010010	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.04113	-118.36069	expedited rses plan check per applicant request.PV 2. ROOF MOUNTED 3.64 KW ROOF MOUNTED PV SYSTEM. INTERCONNECTED TO MAIN PANEL.(14) MODULES   KYOCERA #KU2606XPA(1) INVERTER ABB# PVI-3.0-OUTD-S-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3212	13041-10000-21352	2535 E 12TH ST	90021	14	120A219    28	5168004001	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	PIN	34.02266563	-118.22644618	Title 24 and energy, include emergency lighting. two story .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3213	13041-10000-36136	911 W WILSHIRE BLVD 7TH FL	90017	9	130-5A209 175	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	PIN	34.05047133	-118.25939676	TI IN OFFICES/PANTRYPLAN CHK IS FOR TITE 24PERMIT HAS PULLED ON THE COPY OF THE PLAN PER APPLICANT REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3214	17041-10000-24582	10049 S KALMIA ST 101-202	90002	15	091-5A217 111	6046019929	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/11/2020 12:00:00 AM	ADDRESS	33.94623	-118.23204	NEW 3 STORY, 3 UNIT APARTMENT BUILDING. 400A 208/120 V SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3215	18041-20000-15223	17820 W MARTHA ST	91316	5	174B129   763	2159002074	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Closed	09/04/2020 12:00:00 AM	ADDRESS	34.17294	-118.52107	Plan check for PV roof mounted system with 10.08kWac with 28 AC Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3216	10041-20000-22630	440 S VERMONT AVE #116, 130	90020	13	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM			PC Info Complete	12/07/2010 12:00:00 AM	ADDRESS	34.0659	-118.29143	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT COFFEE SHOP #116 AND STORAGE #130	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3217	12041-20001-17249	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL, [Q]R3-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	07/27/2013 12:00:00 AM	ADDRESS	34.2215	-118.42999	"Existing loads were incorrectly represented on original plan. Plan check only for as-built drawings correctly representing existing equipment.  PLAN CHECK ONLY for ""DELTA J""Replace/upgrade of existing HVAC equipment of Medical building (Kaiser Permanente) with new total connected load exceeds 400A .  Plan check for power only.    Building is Not State Licensed, NOT checked for OSHPD 3."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3218	19041-20000-14111	24045 W PHILIPRIMM ST	91367	3	174B089   518	2046013009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.17105	-118.65097	INSTALLING NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 14.06KW DC/9.12 KW AC. SCOPE OF WORK INCLUDES (38) SILFAB PV MODULES WITH ENPHASE IQ 7 MICROINVERTERS, AND A ENPHASE AC COMBINER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3219	17041-10000-03964	915 W WILSHIRE BLVD #2050	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI, NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3220	17041-20000-12006	535 S HOBART BLVD	90020	10	135B193   780	5503021024	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.06424	-118.30551	permit fee $0.00 by state senate bill no. 1222pv2install roof mounted pv system sized 30kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3221	19041-20001-49373	6204 S BERTHA ST	90042	14	153A231   364	5492028020	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.11197	-118.18642	Expedite per applicant requst Plan check for PV SOLARGLASS(Solar Roofing Tiles), PV system size: 9.12132KW with 156 PV Roofing Tiles and 1 inverter(7.6KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3222	18041-20000-22416	8423 N HILLCROFT DR	91304	12	193-5A089  85	2017016011	RE40-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	PIN	34.2251513	-118.6530197	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (9) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3223	14041-20000-13338	6919 N CASTLE PEAK DR	91307	12	183B085   115	2031010025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.19794	-118.66002	PV1  INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.94KW INTERCONNECTED WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS SOLAREDGE SE 3800A(39) TRINA SOLAR MODULES TSM-PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3224	13041-20000-09260	13455 W MAXELLA AVE STE 110	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	Plan check for power only. Relocation of loads on panel MA. Plan check requested per applicant. Change in load approximately 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3225	17041-20000-21280	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM			PC Approved	06/23/2017 12:00:00 AM	ADDRESS	34.06191	-118.41691	New lighting in corridors for 12th, 14th, and 17th floors.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3226	12041-10000-02074	10620 N OVERMAN AVE	91311	12	207B113   137	2707018022	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	03/21/2012 12:00:00 AM	ADDRESS	34.26299	-118.57776	New 8kw rooftop photovoltaic rooftop system for an existing single family residence.  System uses Enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3227	10041-20000-07624	14051 W BURBANK BLVD	91401	2	174B153   757	2246032013	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.00	Electrical	Electrical	Commercial			04/26/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.17233	-118.43939	NEW WIRELESS TELECOMMUNICATIONS FACILITY ON ROOFTOP OF EXISTING 3-STORY BUILDING. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY IN DOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3228	18041-10001-44661	11671 W NATIONAL BLVD	90064	11	120B153   907	4258009031	C2-1VL, R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Apartment			06/12/2019 12:00:00 AM			PC Info Complete	06/12/2019 12:00:00 AM	ADDRESS	34.02326	-118.43794	"DELTA ""1"" CHANGES TO APPROVED PLANS TO USE ""SILENT KNIGHT IFP-2000"" FIRE ALARM PANEL INSTEAD OF ""MIRCOM"". <<<New fire alarm system for 4-story mixed use building.  FACP with 149 devices.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3229	19041-10000-26654	4807 W ELMWOOD AVE	90004	4	138B193    29	5522020011	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	01/28/2021 12:00:00 AM	ADDRESS	34.07842	-118.31173	PC for new fire alarm system, scope of work includes 55 new fire alarm devices, one communication panel, one control panel and one power supply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3230	17041-20000-25184	16030 W VENTURA BLVD	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.15598	-118.48247	addition of 2 new chillers to an exisitng high rise building.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3231	11041-20000-04513	15302 W RAYEN ST	91343	7	195B145   271	2654011020	C2-1	North Valley	Mission Hills - Panorama City - North Hills			1175.10, 1175.20	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.23178	-118.46597	T.I. to dinning and kitchen area.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3232	16041-10001-06007	5126 N DAHLIA DR	90041	14	163-5A227 359	5669012015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.14037	-118.19959	07/05/16Changes to an approved set of plans. Changes includes rearranging the modules and relocatig the inverters and load center on the site plan/roof-layout. Note: Permit is paid under PCIS#16041-10000-06007((((PV1, rooftop mounted 8.8 kW Ac system using central inverters, (46) modules, (2) 4.2kw  inverters, (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3233	14041-20000-23950	300 S SANTA FE AVE	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	T.I. for a new restaurant.  Install 225KVA transformer, 600A subpanel, branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3234	14041-10000-03293	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	This a high rise 12 story office building, converte to a hotel , 231 guest rooms. power, lighting , indoor and out door title 24, fire alarm deffered, deisel fire pump.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3235	19041-10000-05125	433 S SPRING ST 7TH FLOOR	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	TENANT IMPROVEMENT IN OFFICES-NEW POWER AND LIGHTING CIRCUITS AND NEW PANELBOARDPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3236	18041-10000-36571	3361 W 8TH ST	90005	10	132B193   583	5093025025	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.05783	-118.30221	Energy plan check for a NEW ADDITION TO EXISTING 2-STORY RESTAURANT. Scope includes new lighting and equipment with a total aea of 1364-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3237	18041-20000-19181	4633 N CARITINA DR	91356	3	168B117   496	2178015023	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Issued	06/12/2018 12:00:00 AM	ADDRESS	34.15423	-118.55694	PV1.  Install 18 kW roof mounted grid tied PV system.  (56) modules with (1) 7.6 and (2) 5.2 kW rated string inverters.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3238	13041-10000-31513	13841 N ELDRIDGE AVE	91342	7	228B157  1119	2503003005	(T)RE11-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.32351	-118.43219	PV1, Install 4.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 17 modules Trina Solar TSM-250PA05.18.(((NEW 2-STORY SINGLE FAMILY HOME WITH ATTACHED GARAGE.  2467 SF. PLAN 2 PER SMALL LOT SUBDIVSION TRACT 60341)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3239	14041-20000-23209	6034 N CAHILL AVE	91356	3	177B121   818	2156013040	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/23/2016 12:00:00 AM	ADDRESS	34.17993	-118.54891	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(24) KYOCERA TSM-255 MODULES (24) SOLAR EDGE P300 OPTIMIZERS(1) SOLAR EDGE TRANSFORMERLESS INVERTER SE5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3240	14041-20000-17262	6621 N FALLBROOK AVE 1st  FLOOR	91307	12	180B097   429	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			Reviewed by Supervisor	07/08/2014 12:00:00 AM	ADDRESS	34.19037	-118.62371	pc for fire alarm sytem for the first floor.world market	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3241	15041-20000-36548	11390 W OLYMPIC BLVD 300	90064	11	123B153    61	4260018021	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.03709	-118.44273	Plan check for energy only. TI to existing office. New lighting (incl. emergency). If new receptacles are added, shall comply with control requirements per 130.5(d). 8,391sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3242	13041-10000-11300	7847 S AIRPORT BLVD	90045	11	099B169   566	4106028020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	33.96816	-118.38654	PV1 MICRO INVERTER SINGLE STORY HOUSE. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3243	16041-10000-03040	901 S WESTERN AVE #101&102	90019	4	132B193   885	5093001036	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2126.20	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	PIN	34.05565533	-118.30942786	TENANT IMPROVEMENT IN EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3244	15041-20001-07581	10031 N TOPEKA DR	91324	12	204B121   494	2729004024	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	ADDRESS	34.25286	-118.54595	Supplemental application for expedite fees.Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  Two inverter system with 40 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3245	16041-10004-41235	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	09/21/2018 12:00:00 AM	ADDRESS	33.97954	-118.42015	Delta-6: Change to approved set by modifying the lighting plan. All changes under delta-6 only.SCOPE INCLUDES REMOVAL OF LIGHTING IN ENTRY WAYS AND ADDING LIGHTING FOR PATH OF EGRESS. SOME REVISIONS TO T24. ALL CHAGES PERTAIN ONLY TO THE CORE AND SHELL STAGE UNDER MASTER APPLICATION. THIS IS PLAN CHECK ONLY. (((PC FOR ENERGY AND POWER. T.I OFFICE IN AN EXISTING ONE STORY BUILDING. DELETING FEEDERS AND ADDITION OF NEW ONES. INTERCEPTING NEW AIR CONDITIONERS TO EXISTING FEEDERS. TOTAL AREA OF LIGHTING 1 03784 SQ FT. B # 16016-10000-28032)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3246	15041-10001-06615	1515 S WESTWOOD BLVD	90024	5	129B153    35	4324026037	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.05365	-118.44058	REVISIONS TO PERMITTED SET OF PLANS: CHANGES FOR LIGHTING AND ADDED CIRCUITS-ALL DELTA 3 CHANGES(((((((Plan check for power and energy. 1st floor renovation and regrigeration. Total area  = 9163 sq. ft. Existing panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3247	17041-10002-30400	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	"DELTA ""I"" ENERGY CHANGES TO AN APPROVED SET PER INSPECTOR REQUEST. SCOPE INCLUDES CHANGES TO THE NUMBERS AND TYPES OF FIXTURES INSTALLED. SCOPE ALSO INCLUDES DELTA ""G"" FOR ADIITION AND REMOVAL OF CIRCUITS ON THE PANEL SCHEDULE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3248	16041-10000-29276	1300 S MIDVALE AVE 1-60	90024	5	132B153   705	4324005***	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.0564	-118.44426	LOBBY REMODEL. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3249	16041-10000-07322	1350 N SAN PABLO ST 1st fl.	90033	14	133-5A225  25	5202005900	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.06068	-118.20361	(TI) New entrance structure to an (E) 2 story (B-occ) build. Scope of work (Phase I) on the the 1st floor. Upgrade main service to 800A 120/240 3-phase, 4W. Total area: 10,105 sq.ft (indoor) + 559 (outdoor).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3250	17041-20000-11821	4501 N CEZANNE AVE	91364	3	165A105    16	2173002011	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.14819	-118.60381	pv1install roof mounted pv system sized 7.6kw interconnected with msp. center fed.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3251	15041-10000-02441	16451 W SHADOW MOUNTAIN DR	90272	11	132B121    24	4420037007	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.06141	-118.54208	Plan check for PV1 rooftop mounted with 10kW  STC. 36 modules and 36 micro-inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3252	13041-10000-34619	15058 W DELANO ST	91411	6	177B145   368	2242024022	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.1824	-118.46158	Remove HID light fixtures and replace with new fluorescent fixtures in industrial work space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3253	15041-10003-24962	8533 N WOODLEY AVE	91343	12	192B137   107	2689025027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.22563	-118.48545	Changes to approved set, Permit under 15041-10000-24962. Changes on Single line diagram to reflects 400A split main, changes noted under Delta-4 on the single line diagram.<<$0 permit fee is due to State Senate Bill SB-1222. PV 1 INSTALLMENT OF NEW 19.293 KW DC ROOF MOUNTED SOLAR ENERGY SYSTEM IN A SINGLE FAMILY HOME. (59) MODULES: SUNPOWER SPR327E-WHT-D (3) INVERERS: POWERONE BLACK PV1-6000-OUTD-US-A>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3254	10041-20000-19741	15750 W STRATHERN ST	91406	6	189B141    84	2206003016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.21559	-118.47652	T.I. for existing space of printing room.  Install general lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3255	18041-10000-41644	3031 S VERMONT AVE	90007	8	120B197   433	5040026046	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.02666	-118.29182	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3256	12041-10000-26774	21933 W VENTURA BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Info Complete	11/07/2012 12:00:00 AM	PIN	34.16940578	-118.60503747	tITLE 24 FOR A COMMERCIAL ONE STORY. RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3257	18041-10000-08798	6600 N TOPANGA CANYON BLVD #60	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR T-24 ENERGY ONLY FOR A TI OF A RETAIL SPACE. TOTAL CONNECTED LOAD IS LESS THAT 200A.  SCOPE INCLUDES NEW PANELS, RECEPTICALS AND LIGHTING. TOTAL  AFFECTED AREA IS 5446 SQ.FT((B#18016-10000-07369))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3258	08041-10001-13153	1377 N SERRANO AVE # 105	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/17/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	REVISIONS TO LIGHTING IN ROOM 105PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3259	16041-10000-23604	3686 E OLYMPIC BLVD	90023	14	118-5A227 222	5191025012	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.01867	-118.19685	Installation of solar system in a commercial site, roof mounted. Installing three different inverter systems. System 3: (3) Central inverters rated at 33.3 kW (SOLAR EDGE, SE33.3KUS) each for a total size of 99.9 kW.  Installing (342) solar modueles. Note: System 1 and System 2 will be plan checked  under seperate permits.System 1 app # 16041-10000-23590System 2 app # 16041-10000-23599	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3260	15041-20001-30500	950 S FAIRFAX AVE	90036	4	132B177   461	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Approved	06/06/2018 12:00:00 AM	ADDRESS	34.05875	-118.3633	06-06-2018 Changes to an approved set of plan. Changes has been clouded. This is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3261	16041-10000-05685	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.21445	-118.48429	NEW SINGLE STORY HANGER WITH OFFICES, 1000MS, TOTAL AREA 86942 SQ FT(CONDITIONED + UNCONDITIONED AND OUTDOOR LIGHTING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3262	11041-10000-19133	12324 W VENTURA BLVD	91604	2	162B165   254	2369002025	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	09/09/2011 12:00:00 AM	ADDRESS	34.14284	-118.40161	T.I. TO AN EXISTING BEAUTY SALON.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3263	17041-20000-29290	8110 N WOODMAN AVE Procedure-1813	91402	6	189B157    55	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.21819	-118.43077	Plan check for power and energy. Project site is an existing medical office building. Project scope is the tenant improvement of a shell space; converting the space into a procedure room. Total ligthing area = 360 sq. ft.Note: Building application has been generated under 17016-20000-23814	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3264	18041-10000-10667	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	FULL PC FOR A WAREHOUSE, STUDIO BUILDING TI. SCOPE OF WORK INCLUDES NEW 4000A, 277/480V SERVICE., NEW CIRCUITS AND LIGHTING. TOTAL SQ. FT. 163,096B# 18016-10000-08591	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3265	13041-10000-12189	1710 N SILVER LAKE BLVD	90026	13	144A205   208	5423022002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.0895	-118.26816	((was final even though plans are expired. redid plan check and permit fees.5/10/13))T.I. for existing commercial space(restaurant). EPC: Energy(t-24). Permit for 7 ckts and 1 equipment > 3kva under this application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3266	18041-10000-33858	905 E 2ND ST 108	90012	14	129A215   387	5163003063	(T)(Q)C2-2D-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04729	-118.23499	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A RESTUARANT. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND LIGHTING. TOTAL AFFECTED AREA IS 2123 SQ. FT. B#18016-10000-18266	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3267	17041-20001-44984	6640 N VAN NUYS BLVD	91405	6	180B149   272	2237001018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.19188	-118.44844	"08/16/2018 Changes to an approved set of plan (Medical Clinic/Surgical Center). Changes include reduced generator size to 100kW 120/208 3 phase, eliminate 2 ATS and keep 1ATS, combined panel""ME"" and ""M"", essential loads are to be on only 1 ATS, relocate distribution ""E"" to essential load, no additonal equipment, reconfigured Single Line diagram. All changes has been clouded. Delta 1.((((((Plan check for power and energy. TI/Change of use to medical clinic/surgical center. New 125kW emergency generator. T24 area - 3,002 sq ft. Not OSHPD.)))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3268	17041-10000-07699	9004-9016 W VENICE BLVD	90232	5	120B169   173	4206032046	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	PIN	34.0269488	-118.39169737	PERMIT FOR WORK FOR UNITS 9004 - 9016 AS SHOWN ON ADDRESS. PLAN CHECK ONLY FOR UNITS 9004. ONLY WORK WITH LIGHTING UPGRADES. PC FOR T24 ENERGY ONLYNote: Partial electrical permit fees have been paid for under 16041-30000-42644	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3269	15041-20000-14925	19911 W NORTHRIDGE ROAD	91311	12	207B113   154	2708020019	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.26201	-118.56715	Installation of new GROUND MOUNTED solar PV array.  Total system size = 12.9 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3270	11041-20000-21363	12219 W JEFFERSON BLVD	90230	11	105B161   955	4220007037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			PC Approved	10/06/2011 12:00:00 AM	ADDRESS	33.9818	-118.40862	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3271	11041-10000-23853	650 N LACHMAN LANE	90272	11	129B121   627	4419014038	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	ADDRESS	34.04827	-118.54632	ROOF INSTALLATION OF A 11KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3272	14041-20000-31743	15955 W STRATHERN ST	91406	6	189B141    23	2206005021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.2158	-118.48076	PV2. COMMERCIAL ROOF MOUNTED SOLAR SYSTEM.  NEGATIVELY GROUNDED SYSTEM. SYSTEM SIZE: 451 KW DC.(784) LONG SLSM 230P(874) CANADIAN SOLAR CS6X(8) SOLECTRIA PVI-20TL(8) SOLECTRIA PVI-28TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3273	17041-20000-25647	631 S OLIVE ST ste 900a	90014	14	129A209   124	5144004032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.04749	-118.25498	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3274	17041-20000-04949	573 S BOYLE AVE	90033	14	126A221     2	5174001015	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.04034	-118.21997	Plan check for power only. New 800A service for existing Senior Assisted Living structure. Note: feeders, panels, and generator were approved by OSHPD and are not in the scope of this plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3275	13041-10001-19342	1611 N NAUD ST	90012	1	136-5A217  49	5409002031	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.06819	-118.22779	CHANGES TO APPROVED set of plans: NO SPACE ON MP FOR 125BKR. instead, PUTTING MPA (fully rated) ON THE XFMR (112.5kva). Breaker is located <10ft away from transformer. equipment, terminals, and conductors using 75C  (10/10/2013 mt - 3 changes on the plans). TENANT IMPROVEMENTS TO AN EXISTING BUS MAINTENANCE FACILITY.  CHANGE OF USE FOR PORTIONS OF BUILDING FROM MAINTENANCE TO OFFICE AND CONSTRUCT (N) WALL OPENINGS FOR BUSES. no work being done in hazardous location per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3276	12041-20000-27656	6000 S ST ANDREWS PL	90047	8	105B193   568	6001017901	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.00	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	33.98489	-118.31134	Change to lighting to an existing animal shelter.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  (Emergency lighting is NOT a part of this plan check.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3277	16041-20000-00448	12821 N WOODLEY AVE	91344	12	222B133   484	2609002024	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.30303	-118.49987	Plan check for PV roof mounted system. System size: 6.0kWac with 25 modules and 25 microinverters. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3278	17041-20000-15357	9120 N AQUEDUCT AVE	91343	12	198B141   763	2671011024	(Q)R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.23635	-118.4737	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN. SYSTEM SIZE: 4.91 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3279	14041-20001-03433	22471 W SUENO ROAD	91364	3	168B101   221	2075038012	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.15904	-118.6159	Expedite Fee only*****Roof mounted PV system with 6KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3280	18041-10000-02285	380 WORLD WAY SPACE T20	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC for power and energy for retail TI(first time tenant) in LAX. Installing new panel, lights and receptacles. Total area is 355sqft. B# 17016-10000-36312:TENANT IMPROVEMENT IN EXISTING  SHELL SPACE FOR  RETAIL STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3281	16041-10000-25540	1318 E 7TH ST 501,502,50-3,504,505	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.03608	-118.24052	Plan check for Energy (T-24) only.  TI to an (E) commercial building, install new lights and receptacles. Newly connected connected load < 400A. Total affected area: 4,100 sq.ftRef. B# 15016-10000-06687, E# 16041-10000-00572	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3282	14041-10000-27951	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.14436	-118.27496	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR KAISER PERMANENTE HOSPITAL. 1 STORY. 60,000 SQFT, EMEREGENCY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3283	11041-10002-04961	525 S FLOWER ST FLRS 1-3	90071	9	130-5A209 146	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	11/15/2011 12:00:00 AM	ADDRESS	34.05109	-118.25696	DELTA 14 CHANGES- USED A DIFFERENT TYPE OF EM LUMINAIRES ON EACH FLOOR((((((((T.I.  NEW OFFICE BUILDING ON FLOORS 1 THRU 3.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3284	12041-10000-20325	630 S ST LOUIS ST	90023	14	126A221   122	5183023003	[Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Public Safety Only			08/28/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.03789	-118.21796	INSTALLATION OF A FIRE WARNING SYSTEM IN AN EXISTING APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3285	15041-10001-24705	3813 W EVANS ST	90027	4	150B201   669	5433024012	R2-1XL	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM			Reviewed by Supervisor	08/11/2015 12:00:00 AM	ADDRESS	34.10706	-118.27431	PV1, ROOF MOUNTED SYSTEM, 40 MODULES, 1- 3KW AND 1- 5KW INVERTER. TOTAL SIZE 10.6KW. (40) KYOCERA #KU2656ZPA(1) ABB- PV1-3.0-OUTD-S-US-Z-A(1) ABB- PV1-5.0-OUTD-S-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3286	13041-10001-22517	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM			PC Approved	05/19/2015 12:00:00 AM	PIN	33.93847109	-118.41935625	REVISED SINGLE LINE DIAGRAM SHOWING NEW PANEL AF8 SUPPLYING AN EXISTING LOAD WITH METER; SUBPANEL LP TO SUPPLY NEW 15KVA  PWR CTR FOR ADDITIONAL  POLE-MOUNTED LUMINAIRES; UPSIZED GROUND WIRES AND CONDUITS FOR CIRCUITS SUPPLYING POLE-MOUNTED LUMINAIRES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3287	15041-10000-27022	12700 W MILLENNIUM #45	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1 1.5KW ROOF-MOUNTED SYSTEM WITH (6) (spr-x20-250 SUNPOWER AC-MODULES INTERCONNECTING THROUGH A SUB-PANEL. APPLICATION IS PLAN CHECK ONLY, PERMIT FEE IS PAID UNDER 1S 15041-90000-26266	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3288	16041-20000-14645	16657-16659 W ARMINTA ST	91406	6	189B137    29	2205009031	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.21501	-118.49656	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 60KW INTERCONNECTED TO UTILITY GRID.$0 permit fee is due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3289	19041-20000-47996	6533 W CAHUENGA TER	90068	4	153A187   419	5577027041	R1-1	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	34.11179	-118.33261	PV1.  Install 11.2 kW DC roof mounted grid tied PV system.  (28) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3290	17041-20000-09828	22950 W VANOWEN ST STE-E	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.19343	-118.62746	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT . NEWLY LOAD EXCEEDING 400 AMPS.BUILDING PERMIT # 17016-10000-06045	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3291	15041-10000-27125	5201 N LAUREL CANYON BLVD	91607	2	171B165  1234	2347018012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Info Complete	09/18/2015 12:00:00 AM	ADDRESS	34.16518	-118.39681	PC for energy, T-24. TI, for a commercial site (Bank of America). Scope of work: Rennovations for two offices inside the bldg. Total sq ft: 2526.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3292	10041-10000-25704	6026 N WHITSETT AVE 1-17	91606	2	177B165   614	2333010005	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			12/28/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.18031	-118.40501	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3293	16041-10001-06619	7718 N HATTON PL	91335	12	189B129  1202	2120008017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM			PC Approved	03/25/2016 12:00:00 AM	ADDRESS	34.21092	-118.52318	EXPEDITED FEES PER APPLICANTS REQUEST. (((PV1, ROOF MOUNTED SOLAR SYSTEM USING 2 CENTRAL INVERTERS. (34) MODULES,  (1) 6KW INVERTER AND (1) 3.8 KW INVERTER. TOTAL SIZE IS 11.1KW -DC)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3294	14041-20001-27126	4413 N PETIT AVE	91436	5	165B137    98	2289028014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.15145	-118.4965	expedite per customer request.install roof mounted pv system sized 13.6kw interconnected with msp.(62) kyocera kd255 modules(62) power optimizers p300(3) solar edge inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3295	12041-10000-05133	254 S OCEANO DR	90049	11	132B141   465	4404033009	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Refund in Progress	05/30/2012 12:00:00 AM	ADDRESS	34.05803	-118.47264	New rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3296	14041-10000-34523	7265 N COLDWATER CANYON AVE	91605	2	186B161   583	2327016008	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Expired	01/05/2017 12:00:00 AM	ADDRESS	34.20274	-118.4156	Titke 24 only, emnergency lighting in place to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3297	19041-10000-39728	12173 W GREENOCK LANE	90049	11	135B141   466	4402026022	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	08/17/2021 12:00:00 AM	ADDRESS	34.06562	-118.47842	[EPLAN] PLAN CHECK FOR 2 NEW ESS(TESLA POWERWALL) CONNECTD TO EXISTING PV SYSTEM AND EXISTING 200A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3298	16041-20001-45443	5010 N PALOMAR DR	91356	3	171B117   547	2175004007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM			PC Approved	01/20/2017 12:00:00 AM	ADDRESS	34.16137	-118.55328	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3299	17041-10000-26055	737 S BROADWAY	90014	14	127-5A209  77	5144014030	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	12/11/2023 12:00:00 AM	ADDRESS	34.04443	-118.25434	PC FOR RESTROOM TI IN A HIGH RISE BUILDING  ON THE BASEMENT LEVEL AND 2ND TO 8TH FLOORS FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 1810 SQ.FT. SCOPE INCLUDES NEW LIGHTS RECEPTACLES  AND  CIRCUITS.  B# 15016-10000-03746	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3300	17041-10001-23761	1626 S LONG BEACH AVE	90021	14	120A213   271	5167002038	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.02242	-118.24254	EXPEDITE PER APPLICANT REQUEST.(((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING ROOF-TOP. TOTAL SYSTEM SYSTEM SIZE IS 16.8 KWdc / 15.0 KWac.(42) MODULES-SOLARBINE SB-M380NA1 & SB-S410SA1(1)INVERTER-STL15000TL-US(1)TRANFORMER-15KVA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3301	15041-10000-22144	7514 N HASKELL AVE	91406	6	186B141   235	2206013012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			07/13/2015 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.20712	-118.47477	NEW APARTMENT 6 UNIT BUILDING.  600 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.  NO FIRE ALARM VARIANCE NEEDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3302	18041-20000-40155	13445 N GLENOAKS BLVD	91342	7	225B145    79	2501021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Apartment			10/19/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.31638	-118.4614	Plan check for Title 24 only for common area in existing domitories, newly connected load less than 400A. Total area: 5184 sq ft. B#18016-20000-11030	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3303	10041-10000-12218	523 W 6TH ST Suite 541	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			06/25/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	08/02/2010 12:00:00 AM	PIN	34.04872199	-118.25441618	T-24 and emergency lighting plan check for suite 541.  Inspector to verify that multi level occupancy sensors have been installed in all rooms for which the 0.2 PAF have been indicated on the LTG-2C form.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3304	10041-10000-03056	6750 W SUNSET BLVD	90028	13	147A185    92	5547021001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/22/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	ADDRESS	34.09769	-118.33815	NEW RESTAURANT- CHICKEN FILLET	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3305	17041-10000-14017	1929 S GARTH AVE	90034	10	126B173   512	4302029037	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/20/2017 12:00:00 AM	ADDRESS	34.04225	-118.37882	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(10)MODULES-SOLARWORLD SW 290 MONO (10)OPTIMIZERS-P300-(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3306	19041-20000-49854	5832 W VIRGINIA AVE	90038	13	144B189   524	5534017016	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			12/04/2019 12:00:00 AM	09/23/2020 12:00:00 AM		Permit Finaled	04/26/2022 12:00:00 AM	ADDRESS	34.09167	-118.31685	PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A NEW 800A (120/240V, 3PH, 4W) SERVICE THAT IS CONNECTED TO A NEW 400A(120/240V,3PH,4W) SWITCHBOARD AND A NEW 600A(120/240V, 1PH, 3W) SWITCHBOARD THAT FEEDS DWELLING UNITS AND HOUSE LOADS. NEW LIGHTING, SUB-PANELS AND BRANCH CIRCUITS. TOTAL AFFECTED AREA IS 9,520 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3307	14041-20000-18655	13626 N SHABLOW AVE	91342	7	228B161   550	2580003021	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.32044	-118.40808	PV1.  Install 12.753 kW roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3308	18041-10000-01204	6415 N DE SOTO AVE	91367	3	180B109   593	2149003030	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.18728	-118.58869	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3309	13041-20000-14811	6934 N CANBY AVE	91335	3	183B125   593	2125011021	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	PIN	34.19602557	-118.53438459	INTERIOR OFFICE TENANT IMPROVEMENT, CHANGE OF USE  OFFICE/INDUSTRIAL  TO  OFFICE/VET. LABRATORY.   Load is less than 400 amps, no hazardous/classified areas per applicant.  Plan check only for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3310	18041-10000-22309	7119 N OWENSMOUTH AVE	91303	3	183B105   329	2111025013	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.19977	-118.60173	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3311	11041-20000-24188	4426 W YOSEMITE WAY	90065	14	159A219   114	5684027007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Expired	02/25/2014 12:00:00 AM	ADDRESS	34.13101	-118.22522	pv system microinvereter variance on file.  Inspector to verify that each page of the plan is stamped and signed by the electrical engineer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3312	12041-10000-28200	6333 W SUNSET BLVD	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM			PC Approved	01/24/2013 12:00:00 AM	ADDRESS	34.09817	-118.32753	TENANT IMPROVEMENT TO EXISTING RESTAURANT. NEW RESTROOM, PARTITIONS, REPLACE KITCHEN, MILLWORK AND FINISHES.PLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3313	15041-20000-43994	1840 S CENTURY PARK EAST 6&13-16FL	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	Plan check for Title 24 only for T.I. and alteratons in the restrooms typical for 6th, 13th, 14th,15th, and 16th floor. Total area: 1800 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3314	13041-20000-34217	510 S BROADWAY	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.04767	-118.25088	T. I. TO (E) RESTAURANT. TOTAL OCCUPANT LOAD EXCEEDS 100. PLAN CHECK FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3315	14041-10000-18122	1225 N AVENUE 63	90042	14	159A231   290	5483020022	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.12785	-118.18181	Install roof mounted solar system on existing residential building.  Total system size = 3.6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3316	18041-10000-24460	4960 E HUNTINGTON DR SOUTH #102	90032	14	144A235   333	5218009020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.08745	-118.17453	"PLAN CHECH FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR NEW TI, LITTLE CAESAR'S  ""TAKE OUT ONLY"" PIZZA. THIS IS THE ONLY TENANT THAT CONNECTS TO EXISTING 400A SERIVICE. TOTAL AFFECTED AREA = 1487 SF.(B# 18016-10000-18409 & 18016-10000-20890)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3317	10041-10000-18074	3335 S FIGUEROA ST USC # 2	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.02224	-118.28008	FIRST TIME TENANT IN 8-STORIES , MIXED-USED BUILDING- COFFEE SHOP SEATTLE'S BEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3318	15041-10000-01850	120 S ORLANDO AVE	90048	5	138B173   690	5511015005	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.07385	-118.37301	Plan check for fire alarm system. System is to be installed in a (5)-floor, (35)-unit apartment building. System consists of (150) devices, (2) remote power supplies, and (1) FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3319	15041-10001-14936	10423 W TUXFORD ST	91352	7	198B177   196	2544022016	RE40-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.23561	-118.35812	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1 INSTALL 12.22 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (47) MODULES: KYOCERA  KU2606XPA(2) INVERTER: PVI-5000-PUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3320	17041-20000-23724	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	08/30/2022 12:00:00 AM	ADDRESS	33.76094	-118.29308	ti to an existing commercial building.  adding new lighting new controls to existing panels.  total square footage 102184.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3321	13041-10000-22071	15030 W VENTURA BLVD	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.15272	-118.46063	TENANT IMPROVEMENT FOR AN EXISTING STARBUCKS. PLAN CHECK FOR TITLE 24 PART 6 ENERGY. SCOPE OF WORK LESS THAN 400A.1 STORY. 1273 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3322	15041-10000-41056	7373 W BEVERLY BLVD	90036	5	138B181   398	5526037016	C2-1VL-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			Reviewed by Supervisor	01/13/2016 12:00:00 AM	ADDRESS	34.07631	-118.35069	PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE 2-STORY BEAUTY PARLOR TO MEDICAL OFFICE BLDG. BUILDING PERMIT #: 15014-10000-05528	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3323	14041-20000-19844	455 S LORRAINE BLVD	90020	4	135B189   602	5504003011	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.06565	-118.32015	$0 permit fee due to senate bill 1222 from 2012PV1.  Install 19.1 kW roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3324	17041-20000-34124	20839 W ROSCOE BLVD	91306	3	192B109   685	2780005018	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Winnetka		1132.34	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Issued	09/22/2017 12:00:00 AM	ADDRESS	34.22014	-118.58771	Plan check for energy only. Lighting retrofit (flourescent to LED) for commercial retail building (CVS). Reducing wattage more than 50% per 141.0(b)2I.ii. of the California Energy Code.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3325	13041-10002-30121	18005 W DALI DR	91344	12	219B125    27	2601064010	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.29809	-118.52741	Expedited RSES plan check per applicant request.(((PV1, Install 7.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 29 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3326	15041-10000-40134	11755 W WILSHIRE BLVD 18TH FLOOR	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Issued	12/08/2015 12:00:00 AM	PIN	34.04869377	-118.46238681	PC for Energy only. Total area: 1,667sq.ft(UPGRADE NON-COMPLIANT RESTROOMS TO ADA COMPLIANT RESTROOMS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3327	19041-20000-19644	653 N RADCLIFFE AVE	90272	11	126B125   422	4412014036	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.04252	-118.53087	addition of (2) tesla powerwalls ESS rated at 5KW each to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3328	14041-20000-31668	300 W AVENUE 33	90031	1	142-5A221 290	5205006053	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.08346	-118.21585	PV2. ROOFMOUNTED COMMERICIAL SOLAR SYSTEM. SYSTEM SIZE: 225 KW DC SYSTEM.(750) HANWHA SOLARONE HSL 72P MODULES, (7) SOLECTICA 28KW INVERTERSNote: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3329	17041-10000-33127	7440 N HAYVENHURST PL	91406	6	186B137   141	2205010905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.20637	-118.49217	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 9350 SQ.FT (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3330	15041-10000-30571	1601 W FLORENCE AVE	90047	8	102B193  1254	6015035033	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	33.97473	-118.30486	Full PC. Service upgrade to an exisiting bldg change of use from storage to laundry mat. 800 amps service, pc for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3331	14041-20000-03241	772 N RIDGEWOOD PL	90038	13	141B189   102	5535004027	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.08556	-118.3145	PV1 SINGEL FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3332	12041-10000-09468	7014 N ENCINO AVE	91406	12	183B129   492	2228027003	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	06/20/2012 12:00:00 AM	ADDRESS	34.19797	-118.51408	INSTALLATION OF 6.867KW  PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3333	18041-10000-12937	900 S GAYLEY AVE	90024	5	135B149   564	4363017004	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	03/08/2021 12:00:00 AM		Issued	03/08/2021 12:00:00 AM	ADDRESS	34.06331	-118.44808	PLAN CHECK FOR POWER AND ENERGY FOR NEW 4-STORY MEDICAL OFFICE WITH RETAIL ON GROUND FLOOR AND 3-LEVEL SUBTERRANEAN PARKING. EQUIPMENT CONSIST OF 1600A 480/277V DISTRIBUTION EQUIPMENT WITH ASSOCIATED EQUIPMENT - TOTAL AFFECTED AREA 86654 SQ. FT.  b#16010-10000-03980	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3334	18041-20000-38705	677 N NIMES ROAD	90077	5	144B153   836	4362017008	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	34.08878	-118.43932	Plan check for power only. Project site is a new 3-story single-family dwelling. Work includes a new 800 Amp service.Note: Building permit has been issued under 17010-10000-00550. Electrical permit fees have been paid for under the combo building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3335	19041-20000-09470	5759 N LANKERSHIM BLVD	91601	2	174B169   355	2338023010	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.17547	-118.38124	Change of use from retail to restaurant.  New 400A service connection, meter, and 300A subpanel.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3336	19041-20001-01479	3449 S MCLAUGHLIN AVE	90066	11	117B157   624	4249022004	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.01524	-118.42991	01-17-2019 Changes to an approved set of plan, changes include reloacte equipment( Powerwall and disconnect) All changes has been cloued. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3337	16041-10001-40590	11058 W CHANDLER BLVD	91601	2	171B173  1406	2350014015	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Issued	07/12/2018 12:00:00 AM	ADDRESS	34.168	-118.37216	Supplemental PC for changes to approved set. Changes include new lights, receptacales, panels, equipment  removal of fire pump, addition of electrical room and addition of transformer disconnects. All changes clouded under delta 1,2,3,4,5.This is plan check only! Permit for scope to be collected under 10002	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3338	11041-10002-12353	620 W 2ND ST	90012	14	132A211    61	5151004913		Central				2075.02	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	04/06/2012 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.0545	-118.25027	NEW MUSEUM BUILDING. THIS INCLUDES PANELBOARDS & CIRCUITS.   <<<PARKING BUILDING CHECKED UNDER DIFFERENT APPLICATION.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3339	10041-20000-04119	16660 W VENTURA BLVD	91436	5	168B137   345	2289020014	C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/08/2010 12:00:00 AM	03/08/2010 12:00:00 AM		Permit Finaled	03/31/2010 12:00:00 AM	ADDRESS	34.15807	-118.49682	Installing lighing and receptacles in Chiropractic office. No patient care bed inside the office. This plan check is only for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3340	14041-10000-27481	3620 S MCCLINTOCK AVE	90089	9	129B193  1466	5075011001	USC-1A, [Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2227.00	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.0213	-118.28935	Energy plan check for replacing new light in same location inside two offices. Total area covers 420 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3341	19041-20000-25351	801 S FIGUEROA ST ste 2000	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Issued	07/26/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	ti to an exisitng commercial building.  adding new lighting new wcontrols to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3342	15041-10001-34640	1096 N WESTERN AVE 1-4	90029	13	144B193   795	5536023022	C2-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM			PC Info Complete	10/06/2016 12:00:00 AM	ADDRESS	34.09041	-118.30895	10/05/16Changes to an approved set of plans. All changes are clouded under delta 2. Changes include relocating feeders on different sections of the 1600A main distribution panel, upgrading the elevator KVA rating, and removing two sections. ((((Plan check(fire damage) in existing building(2 stories) core and shell power and energy. New 1600A Service, equipments, panels and circuits. Total area: 12,662sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3343	19041-20000-08860	17404 W REVELLO DR	90272	11	126B117   407	4416023006	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.04128	-118.55714	Plan check for PV roof mounted system and energy storage system, PV system size: 7.47KW DC, 7.28KW AC CEC with 24 PV Modules and 24 microinverters, 1 Tesla Battery 13.2KWh, sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3344	10041-10000-19558	5914 N MONTEREY ROAD	90042	14	150A231   180	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.00	Electrical	Electrical	Commercial			10/01/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	12/16/2010 12:00:00 AM	ADDRESS	34.10502	-118.18425	Existing one story bldg with mez. Service , service equipment, and panels are existing. power,  lighting, title 24, with a little cafe.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3345	19041-10000-15780	11451 N WOODLEY AVE	91344	12	213B141   478	2681008024	A1-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.27845	-118.4849	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3346	11041-10001-01082	533 S WESTERN AVE C	90020	4	135B193   779	5503018003	C2-1	Central	Wilshire			2117.04	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM			PC Approved	04/20/2011 12:00:00 AM	ADDRESS	34.06437	-118.30928	T-24 and emergency lighting for RETAIL SPACE changed TO DINE IN RESTAURANT  (TI)  (~ 1820 SF) CHANGE OF USE   <<<<<<<<<<<<<CHANGE TO LIGHTING FROM APPROVED SET OF PLANS, T-24 AND EMERGENCY LIGHTING ONLY, OTC PLAN CHECK>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3347	10041-10000-21541	1811 N HILLHURST AVE	90027	4	150B197  1085	5590019024	P-1	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM	10/28/2010 12:00:00 AM		Permit Finaled	12/06/2010 12:00:00 AM	ADDRESS	34.10398	-118.28757	Payment office title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3348	10041-10000-25267	733 N NEW HIGH ST # C	90012	1	133-5A215  77	5408023004	C2-2	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.06106	-118.23828	ADDING PANEL AND CIRCUITS IN BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3349	17041-10000-23194	723 N CROFT AVE	90069	5	141B173   359	5528001028	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM			Reviewed by Supervisor	08/04/2017 12:00:00 AM	ADDRESS	34.0843	-118.37443	15 UNIT APARTMENT. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3350	17041-10000-32427	12918 W WEIDNER ST	91331	7	213B161   717	2533027003	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Issued	09/11/2017 12:00:00 AM	ADDRESS	34.27894	-118.41403	New rooftop solar system 7.6 kW AC system. (1) inverter (31) modules (31) power optimizer	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3351	16041-20000-08617	6677 N BIRCHTON AVE	91307	12	180B093   214	2036026036	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.19194	-118.6415	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3352	13041-20000-30172	19344 W WINGED FOOT CIR	91326	6	216B117   260	2822009018	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.28631	-118.55482	PV1 3 STRING SYSTEM. TOTAL SYSTEM SIZE 7.5 KW. 36 MODULES AND 1 INVERTER. THIS IS A PLAN CHECK ONLY APPLICATION. PERMIT ALREADY PULLED ON APPLICATION#: 13041-20000-21440.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3353	17041-10001-10639	1318 E 7TH ST STE 206	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.03608	-118.24052	CHANGES TO APPROVED SET OF PLANS. CHANGES TO FLOOR PLANS. PROVIDED NEW LAYOUT AND UPDATED PANEL SCHEDULED. UPDATED T24. CHANGES CLOUDED DELTA 6,7,8. THIS APPLICATION IS PC ONLY. PERMIT COVERED UNDER MASTER APP.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3354	15041-10000-22885	1025 W 190TH ST STE 102	90248	15	060B197   535	7351029020	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			PC Approved	07/17/2015 12:00:00 AM	ADDRESS	33.85848	-118.29375	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISITING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1666.  PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-40000-18520.THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3355	16041-10000-08073	453 S KENMORE AVE	90020	10	135B197   753	5502013018	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Apartment			03/08/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.06567	-118.29698	NEW FIVE STORY APARTMENT BUILDING, 69 UNITS, ON TOP OF TWO AND ONE HALF LEVEL ABOVE GRADE PARKING STRUCTURE. 3000 MSA, 13 Typical units. Total area: 61,992sq.ft (indoor) + 3,027 sq.ft (outdoor). Building is on METHANE ZONE and No work is done underground inside the building.**Fire Alarm variance is filed together with this application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3356	14041-10000-08715	1828 S OAK ST	90015	1	124-5A203  22	5124017002	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.03705	-118.27728	PLAN CHECK FOR REPLACING   SWITCHBOARDS  WITH SAME BREAKERS AND SAME LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3357	10041-10000-19996	3785 W WILSHIRE BLVD APT 2305	90010	10	135B193  1023	5503030903	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.06187	-118.30858	NEW RESIDENTIAL APARTMENT.  SUITE # 2305. CORE & SHELL APPROVED UNDER A DIFFERENT PCIS#.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3358	16041-20000-28097	9013 N OAK PARK AVE	91325	12	195B133    19	2690005014	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Expired	10/02/2018 12:00:00 AM	ADDRESS	34.23488	-118.50578	PERMIT FEE $41.47 BY STATE SENATE BILL NO. 1222PV1.  Install 13 kW roof mounted ungrounded PV system.  SolarEdge 11.4 kW inverter with power optimizers and (50) 260W modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3359	19041-10000-07972	11327 N MODENA LANE	91326	12	213B109   186	2701053005	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.27829	-118.5834	NEW ROOF MOUNTED 9.135 KW PV SYSTEM WITH 29 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3360	11041-20000-19160	8521 N FALLBROOK AVE s.100	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31, 1132.32	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.22368	-118.62797	office t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3361	14041-20001-19233	8751 N WHITE OAK AVE	91325	12	195B129   338	2768012037	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM			Corrections Issued	07/21/2014 12:00:00 AM	ADDRESS	34.23016	-118.52026	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 12kW(2) SolarEdge #SE6000A-US-ZB-U transformerless inverters(66) SolarEdge P300 power optimizers(66) Trina Solar #TSM-255PA05.18 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3362	14041-10000-20700	8985 W VENICE BLVD UNIT K	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.02733	-118.39241	PLANCHECK FOR POWER AND ENERGY (2013 standards). FIRST TIME TENANT PIZZA RESTAURANT. See 15041-90000-00474 for extension of underground conduit. BLDG#14016-10-15186	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3363	10041-10000-22260	241 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04997	-118.22706	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3364	16041-20000-29419	12117 W VALLEYHEART DR	91604	2	165B165  1095	2367014040	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			08/18/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.14595	-118.39679	Plan check for power and energy. New 23 unit apartment building,  5 story w/roof deck over 1 level subterranean garage. 1600A service. 18,960sqft. Fire Alarm Variance filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3365	13041-20000-32307	10960 W RATNER ST	91352	6	189B173   156	2409003045	[Q]C2-1L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Apartment			11/19/2013 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.2169	-118.36921	NEW 9 UNIT APARTMENT BUILDING. 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3366	14041-10000-12146	13220 W SATICOY ST	91605	2	186B157   213	2303023035	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.2077	-118.42098	Title 24 only - remove HID fixtures and replace with flourescent light fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3367	12041-20000-04069	10329 W PALMS BLVD 1-31	90034	5	120B161   400	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.02679	-118.40832	Temporary power for a new construction site to power crane and lifting equipment.  Install new 150 KVA transformer, panel, and crane and personal lifts.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3368	14041-10000-32207	2915 E 11TH ST	90023	14	120A221   182	5170025015	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.02151	-118.21551	Energy plan check for a commercial area	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3369	18041-20000-27276	3986 N DRYSDALE AVE	90032	14	145-5A233 201	5307011003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	Yes	2011.10	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.09228	-118.17519	PV1.  Install 5.525 kW roof mounted grid tied PV system.  (17) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3370	13041-20001-20854	18240 W ACRE ST	91325	12	195B125   737	2769021028	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	ADDRESS	34.22986	-118.53091	((EXPEDITE FEE))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.886 KW. USING TRANSFORMERLESS INVERTER. 18 MODULES. 1 CENTRAL INVERTER. 3 STRINGS FOR 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3371	16041-20001-41756	818 W 7TH ST	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.04895	-118.25943	[[12/20/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES. PROVIDING EMERGENCY RELAYS AND PHOTOMETRIC CALCULATIONS.]]]]T-24, PC FOR ENERGY ONLY LOBBY RENOVATION AND ADDITION OF NEW SEATING PADS ON THE 2ND FLOOR AND DECORATIVE FIXTURE HANGING FROM 3RD FLOOR.SCOPE INCLUDES NEW LIGHTS FOR LOBBY AREA. TOTAL AFFECTED AREA IS 9744 SQ. FT. B#16016-30000-24184	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3372	17041-20000-22595	810 N TEMESCAL CANYON ROAD	90272	11	129B125   560	4412005046	A1-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	34.04659	-118.52991	PLANCHECK FOR T24 ENERGY. OUTDOOR AND INDOOR LIGHTING FOR GARDEN CENTER. 262 INDOOR SQFT + 10281 OUTDOOR SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3373	15041-10000-43529	12715 W SEABEACH PL	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	33.97531	-118.41512	Full plan check for a new building under a single plan, located in the same job site of a Methane ZONE, consists of  (6) new stand alone buildings with (6) different addresses and application numbers; Each building is identical and has 4-story and 6 units supplied by a 600-Amp service;  All electrical work for the plan are identical to  reference electrical applicaton #15041-10000-27550 located at the same site.This plan set includes the entire outdoor site lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3374	14041-20001-07939	25311 S PRESIDENT AVE	90710	15	036B193   432	7410021036	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	33.79441	-118.3044	Fee for expedite only.*****Roof mounted PV system with tranformerless.  System size 3.27KW*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3375	17041-10000-05075	10250 W SANTA MONICA BLVD STE. 1665	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Plan check for power and Title 24.  T.I. to first time retail tenant space ""Vintage"".  Two new subpanels with 30 kVA step down transformer.  New lighting and receptacles.  Total area = 1,066 sq. ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3376	15041-10001-35144	725 S FIGUEROA ST 21ST	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	CHANGES TO APPROVED SET OF PLANS. REDUCE SCOPE OF WORK. LIGHITNG IN OPEN OFFICE AREAS NO CHANGE. ALL CHANGES BLOUDED IN BOLD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3377	18041-10000-32916	125 W 4TH ST	90013	14	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.0488	-118.24807	PLAN CHECK FOR TITLE 24 ONLY FOR EGRESS (MINIMUM LIGHTING) ONLY - FULL PLAN CHECK WILL BE REQUIRED WHEN TENANT MOVES IN - TOTAL AFFECTED AREA = 1625 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3378	16041-30000-18529	1745 S STANLEY AVE	90019	10	126B177   389	5069014009	R1-1	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.04358	-118.36388	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (1) inverter and (15) panels. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3379	19041-10000-24190	225 S 26TH ST STE 4	90402	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Issued	07/08/2019 12:00:00 AM	ADDRESS	34.04772	-118.49098	PC (ENERGY ONLY) FOR INTERIOR TENANT IMPROVEMENT TO EXISTING RETAIL SPACE. AREA 760SF. (SUITE 4)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3380	13041-10002-07685	19600 S MAGELLAN DR	90502	15	057B197    34	7351034074	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	33.85319	-118.29278	(((CHANGES MADE TO APPROVED SET OF PLANS. ADDED NEW PANELS RELOCATED PANELS. FLOOR PLAN MISSING FROM PLANS.)))Power and energy for 3-story office bldg addition to existing 1-story warehouse.  14,132 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3381	19041-10000-26160	10045 S WESTERN AVE	90047	8	091-5A193 170	6058006035	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	33.94405	-118.3093	NEW FIRE ALARM SYSTEM CONSIST OF 1 FA PANEL, 1 EMERGENCY VOICE CENTER, 1 CELLULAR COMMUNICATOR AND 50 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3382	18041-20001-07174	9356 N LEMONA AVE	91343	7	198B149   174	2650034056	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.24086	-118.45871	New fire alarm system for 2 buildings.  Scope of this permit is for classroom building.  (101) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3383	15041-10000-34846	206 E 104TH ST	90003	8	090A205    76	6063018033	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.10	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	33.94184	-118.27145	PV1, ROOF MOUNTED SOLAR SYSTEM TOTAL SIZE 6.095 KW DC. (23) KYOCERA #KU2656ZPA (1)5KW INVERTER. (23) KYOCERA #KU2656ZPA(1) #PV1-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3384	15041-10001-36111	4420 N ROCHELLE PL	91316	5	165B133    86	2292017029	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM			Reviewed by Supervisor	11/03/2015 12:00:00 AM	ADDRESS	34.15144	-118.50849	EXPEDITED FEES PER APPLICANT(((PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE: 12 KW-AC. (54) MODULES AND (2) INVERTERS. (2) SOLAREDGE TECHNILOGIES:SE6000(240V)(54)REC SOLAR: REC275TP)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3385	17041-10000-32098	10780 W SANTA MONICA BLVD 400	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.0504	-118.43387	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4724 SQ. FT. B#17016-10000-24788	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3386	13041-10001-23451	7331 N FIGUEROA ST	90041	14	162A229   274	5690023045	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.13715	-118.18819	replacing luminaires in the dining area and restroomPLAN CHK IS FOR TITLE 24REMODEL.  CHANGE OUT LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3387	13041-20000-10130	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM			PC Approved	04/18/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	Change to lighting to an existing retail space.  Load is less than 400 amps per the applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3388	12041-20000-02017	2587 N LOMBARDY BLVD	90032	14	139-5A233 160	5216010029	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM			Corrections Issued	03/19/2012 12:00:00 AM	ADDRESS	34.07639	-118.17629	pv system micro inverter single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3389	14041-20000-05827	21021 W LANARK ST	91304	3	189B105    56	2109007009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.21759	-118.59165	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3390	17041-10000-16619	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	OFFICE TENANT IMPROVEMENT  IN LEVEL 4. new lighting. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3391	17041-10000-07779	921 W 57TH ST	90037	9	108B197  1120	5001012023	[Q]R4-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	33.99061	-118.29005	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWAC.(20)MODULES-SOLARWORLD SW 265 MONO(1)INVERTER-FRONIUS PRIMO 5.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3392	16041-20000-13622	6330 W SAN VICENTE BLVD #401	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.06116	-118.36804	Plan check for Title 24 only. Project site is an existing suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,475 sq. ft.Note: Building permit has been pulled under 15016-10000-25671.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3393	17041-20000-20920	4201 W WILSHIRE BLVD	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.06189	-118.31911	"""0$ permit fees due to senate bill 1222""PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 131 KW.  INSTALLATION OF MEDIUM VOLTAGE TRANSFORMER .building permit # 17016-30000-16741"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3394	19041-10000-13304	821 N AVALON BLVD	90744	15	030B205   267	7423003008	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	33.78064	-118.26266	PLAN CHECK FOR TITLE 24 ONLY FOR ONE STORY COMMERICAL BUILDING. TOTAL EFFECTED AREA 5760 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3395	19041-10000-07705	10824 W BURBANK BLVD	91601	2	174B173  1015	2416014016	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.17199	-118.3668	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 36 FA DEVICES AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3396	17041-10000-36016	314 W 58TH ST	90037	9	108B201  1293	5101040005	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	33.98964	-118.27898	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 92KWac. (259)MODULES-Q.CELLS Q.PEAK-G4.1 300(4)INVERTERS-YASKAWA SOLECTRIA PVI 23TL, $0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3397	18041-10000-08890	5750 W WILSHIRE BLVD	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.06227	-118.3542	PC FOR A FIRE ALARM PANEL AND TRANSPONDER PANEL UPGRADES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3398	13041-20000-13313	11720 W IDAHO AVE	90025	11	126B149   595	4262012004	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	PIN	34.04162917	-118.45524821	T24 FOR EXPANSION OF EXISTING PARKING LOT. 30,226 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3399	17041-10000-24761	11678 W SAN VICENTE BLVD	90049	11	129B145    35	4265006007	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.05361	-118.46459	CAFE TI, PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3400	19041-20000-06160	4730 S LINCOLN BLVD	90292	11	105B153   149	4224014018	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	08/04/2020 12:00:00 AM		Permit Finaled	10/07/2020 12:00:00 AM	ADDRESS	33.97991	-118.438	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is change of use from restaurant to medical office. Total lighting area = 4,685 sq. ft.Note: Building application has been submitted under 19016-40000-03766	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3401	19041-10000-49377	603 S MCCADDEN PL	90005	4	135B185   408	5507018030	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.0647	-118.33729	Plan check for a 7.6KW AC / 11.39KW DC roof mounted system. Scope includes (1) inverter, (34) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3402	16041-10001-44416	5800 W SUNSET BLVD 3rd-4th Floors	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Closed	12/22/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PC FOR CHANGES TO APPROVED SET UNDER DELTA  (A) TO REFLECT CHANGES MADE ON FIELD.SCOPE INCLUDES REMOVAL OF CIRCUITS,  CHANGES TO LIGHTING LOADS AND TITLE-24 REVISION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3403	19041-10000-40101	5625 W CENTURY BLVD	90045	11	090B169    29	4125026010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM			PC Info Complete	10/18/2019 12:00:00 AM	ADDRESS	33.94572	-118.37965	T-24, PC for Energy lighting Only on a restaurant T.I. Scope includes new lighting and equipment with a total lighting area of 4,992-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3404	19041-20003-08992	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.18421	-118.60617	10/3/19Changes to approved set delta 17 only E3.01 and E9.01 Electrical distribution configuration. <<<TI IN A GROCERY STORE. CHANGE OF USE FROM RETAIL TO MARKET. PLAN CHECK FOR POWER & ENERGY. TOTAL AREA: 34,000 SQR FT. OTHER RELATED PERMITS = SHELL: 18041-10K-43843, SERVICE UPGRADE: 19041-20K-04168BUILDING: 19016-10K-07097>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3405	13041-10000-33726	484 S SAN VICENTE BLVD	90048	5	135B173   219	5510005035	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.06911	-118.37479	Plan check for power and lighting and T24,New TI and remodeling office store.(Mehdi Zandi).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3406	17041-20001-43972	8241 N MELBA AVE	91304	12	192B093   469	2020021008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.21895	-118.63442	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.5.2kW ungrounded pv system. (15) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3407	13041-10000-24420	10055 N BEACHY AVE	91331	6	204B153   712	2647021004	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.25385	-118.44454	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 18.13 KW DC IN A TWO-STORY SINGLE FAMILY DWELLING. 2 NEGATIVELY-GROUNDED INVERTERS.(74) MODULES: TRINA SOLAR #TSM-245PC05/PA05.18(2) INVERTERS: FRONIUS #IG PLUS V 7.5, INVERTERS: FRONIUS #IG PLUS V 6	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3408	19041-10000-48306	3418 S HALDERMAN ST	90066	11	114B149   497	4247014012	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	34.00909	-118.44615	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 17  (SUNPOWER SPR X22 370-D-AC) MODULES, 17  (SUNPOWER SPR X22 370-D-AC) MICROINVERTERS, 2 TELSA POWERWALL'S, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 6.29KW DC & 5.44KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3409	13041-10000-17953	1306 N L. RON HUBBARD WAY adv org	90027	13	147B197  1062	5543016019	C2-1	Central	Hollywood	East Hollywood		1912.01, 1912.03	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.09574	-118.29377	New Fire alarm system for an existing scientology church. 321 devices and 1 panel.  5 stories plus roof. full evacuation system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3410	17041-20000-02768	22856 W WYANDOTTE ST	91307	12	186B097   940	2021019012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.20253	-118.62555	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.4 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3411	17041-10000-29094	21300 W VICTORY BLVD 9TH FLOOR	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.18813	-118.59618	PC FOR OFFICE TI  FOR TITLE 24 ENERGY ONLY FOR THE 9TH FLOOR IN A HIGH RISE.  SCOPE INCLUDES NEW PANELS CIRCUITS EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 18218 SQ.FTB#17016-10000-22522	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3412	18041-20002-37685	7945 N BALBOA BLVD	91406	6	189B133   476	2204024014	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.21512	-118.50149	Revision to approved set of plans.  Change of inverter ratings to (1) 10 kW and (1) 7.6 kW rated string inverters.  Change of interconnection point into building wiring system.  Minor wiring revisions. (((Plan check for PV roof mounted system, system size: 23.76KW DC, 22.19KW AC with 72 PV Modules and 2 inverters(10.0KW) connected to 400A panel supply side connection)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3413	13041-10000-06544	6605 N FALLBROOK AVE	91307	3	180B097   311	2038040015	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.18874	-118.62363	fire alarm system for grocery store. total of 37 devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3414	11041-10000-23678	5581 E HUNTINGTON DR	90032	14	147A239   271	5309024018	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Info Complete	12/22/2011 12:00:00 AM	ADDRESS	34.09518	-118.15868	1st time tenant for a new nail/spa.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3415	15041-10000-27538	5900 W SUNSET BLVD	90028	13	147A191    82	5545015001	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.09788	-118.31816	TI for (E) single-story 1690 sq. ft. restaurant space.  Plan check for energy. Circuit fees paid under express permit #15041-10000-25011	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3416	14041-10000-34814	700 W 7TH ST 3RD FLOOR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.04797	-118.25815	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3417	19041-10001-01698	1515 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   315	5036030034	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.01101	-118.30407	CHANGES TO APPROVED SET, ALL CHANGES ARE UNDER DELTA 1 SCOPE OF WORK IS LAYOUT CHANGES ON FLOOR PLAN, T24 HAS BEEN REVISED ACCORDINGLY, NOTE PERMIT HAS NOT BEEN ISSUED YET, ANY ADDITIONAL EQUIPMENT WILL BE PERMITTED UNDER 19041-10000-01698. ORIGINAL SCOPE:PLAN CHECK FOR T24 ONLY, REMODEL AND EXPANSION OF AN EXISTING MINI MART AT A GAS STATION. INSTALL NEW LIGHTSA ND POWER FROM TWO EXISTING PANELBOARDS. TOTAL AREA: 1,572 SQ.FT, NEW CONNECTED LOADS < 200A(B# 19016-10000-01242)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3418	19041-20000-06153	10236 W MOSSY ROCK CIR	90077	5	156B153   196	4382025***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.12205	-118.44372	Plan check for PV roof mounted system, system size: 11.22KW DC with 34 PV Modules and 1 inverter(11.4KW) connected to 225A panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3419	11041-10000-08983	1143 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			PC Approved	05/03/2011 12:00:00 AM	ADDRESS	34.03005	-118.22064	TI, CREATE NEW 2-STORY OFFICE SPACE IN EXISTING WAREHOUSE.  OTC PLAN CHECK FOR T-24 WITH EMERGENCY LIGHTING ONLY.  SUBJECT TO INSPECTOR, FULL PLAN CHECK MAY BE REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3420	16041-10000-26834	7800 W SUNSET BLVD	90046	4	147B177  1001	5551025025	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.09789	-118.35952	PC for lighting only scope of work includes new lights and recepetcles to an existing bank. total sq.ft 6357	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3421	14041-20000-15450	1661 W 240TH ST	90710	15	042B193   713	7439007***	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.80741	-118.3065	TI to 3 commercial warehouse spaces occupying existing single-story building.   Plan check for Title 24 Part 6 for changes to interior lighting system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3422	17041-10000-30180	5880 W JEFFERSON BLVD	90016	10	120B173   380	4205027011	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.02238	-118.37681	PC FOR OFFICE TI. GREATER THAN 400A NEW LOAD. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3423	13041-10000-28795	642 W ETTA ST	90065	1	145-5A221  53	5452004043	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.09439	-118.21753	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS UNGROUNDED. SYSTEM SIZE: 4.25 kW.(17) TRINA SOLAR # TSM-250(1) POWER ONE # AURORA PV1 3.6	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3424	15041-10001-43654	2309 S SPAULDING AVE	90016	10	123B173    34	5064028016	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	ADDRESS	34.03716	-118.3678	03/07/2017 Changes to an approved set of plans. Changes include point of connection. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3425	11041-20000-18555	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.02	Electrical	Electrical	Public Safety Only			08/31/2011 12:00:00 AM	08/31/2011 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.20696	-118.3417	PLAN CHECK NEW FIRE ALARM SYSTEM FOR WOODBURY UNIVERSITY FILM SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3426	13041-10000-36225	300 W WORLD WAY CTA-T-3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Closed	04/20/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	pc for power and energy. TI FOR CANOPY LIGHTING LAX. Terminal 3 CTA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3427	14041-20001-23905	11134 N SEPULVEDA BLVD	91345	7	210B145    89	2664007018	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM			Reviewed by Supervisor	11/03/2015 12:00:00 AM	ADDRESS	34.27303	-118.46738	10-23-2015 Plan check for power and energy for change to approved set of plans,  changes include upgrade service from 800A to 1,200 A and upgrade service equipment to 1,200A, 1 new panel fot IT is being added, added outdoor lighting per T-24. {{{{{{{PC FOR POWER AND ENERGY. CHANGE OF USE OF EXISTING 2 STORY OFFICE BLDG TO A RESCUE MISSION FOR TEMPORARY HOUSING OF HOMELESS. TOTAL AREA = 13994 SQ FT(INDOOR) + 1631 SQ FT(OUTDOOR).B# 14016-10000-16460.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3428	17041-10000-08491	810 E PICO BLVD 226	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.03119	-118.25079	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE(RETAIL). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1269 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3429	11041-10000-06030	2000 S AVENUE OF THE STARS	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	T-24 FOR AN EXISTING OFFICE, OTC PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3430	11041-10000-24443	1033 S DOREEN PL BLDG 3-3	90291	11	111B145   819	4243003033	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	33.99965	-118.45958	LINCOLN PLACE PROJECT. NEW 2 STORY 9 UNITS APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3431	14041-20000-17209	2541 S DUNSMUIR AVE	90016	10	123B177   832	5043002004	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Expired	08/15/2016 12:00:00 AM	ADDRESS	34.0331	-118.35955	PV1.  Install 4.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3432	18041-20000-46974	13405 N ANDALUSIA LANE LOT 5	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.31493	-118.42255	Plan check for PV roof mounted system,system size: 1.68KW with 7 PV Modules and7 microinverters. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3433	10041-20000-01392	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Finaled	02/22/2010 12:00:00 AM	ADDRESS	34.06222	-118.35208	Adding light and relocation existing lights in portion of office area. This P/C is only for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3434	18041-10000-05530	323 E 1ST ST 1ST FLR.	90012	14	130-5A215 306	5161012007	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.05005	-118.2402	PC FOR TITLE 24 ENERGY ONLY FOR  resturant TI.Installing new panel, new lights, receptacles and equipment. Total area 1348sqft. B# 18016-10000-04000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3435	15041-10000-27515	7196 W FORMOSA FUSION CT	90046	5	141B181  1710	5525003035	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08554	-118.34599	PV1 INSTALL NEW 2.KW DC SOLAR ARRAY ON A SINGLE FAMILY HOME.(8) MICRO INVERTER: ENPHASE M215-60-2LL-S22(8) MODULES: S-ENERGY S-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3436	19041-20000-00407	3931 S LYCEUM AVE	90066	11	111B153  1286	4236023013	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	33.99621	-118.4399	Plan check for a PV1 roof-mounted PV system. System size is 6.09 kWdc/7.6 kWac and consists of (1) inverter, (21) modules, (1) auto-transformer, (1) load center, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3437	13041-20000-27133	714 W OLYMPIC BLVD	90015	14	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.04454	-118.26341	T24 FOR NEW EXTERNAL SIGN ILLUMINATED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3438	10041-30000-08470	2029 S CENTURY PARK EAST FL 26 & 27	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	05/12/2010 12:00:00 AM		Permit Finaled	10/04/2010 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI WORK IN 26 AND 27 FLOOR DOING LIGHTING AND POWER. THIS P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3439	14041-10000-33657	10640 N LEMONA AVE	91345	7	207B149   486	2648004006	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.26377	-118.45843	Installation of a PV1 roof-mounted PV system. System consists of (1) inverter and (14) modules. System size is 4.2 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3440	17041-20000-12221	6940 N MCLENNAN AVE	91406	6	183B133   648	2225021008	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.19676	-118.49991	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3441	16041-10000-05647	3456 S WADE ST	90066	11	114B153   557	4247020019	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	03/19/2016 12:00:00 AM	ADDRESS	34.00933	-118.4436	PV1, NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.6KWac.(24) MODULES- SILEVO #TRIEX U300 Black(1)INVERTER- PVI-3.0-OUTD--S(1) INVERTER-PVI-3.6-OUTD-S(1) 125A load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3442	12041-10000-00499	11845 W OLYMPIC BLVD	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/09/2012 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	02/17/2012 12:00:00 AM	PIN	34.03325831	-118.45191172	NEW/ REPLACING  LUMINAIRES AND OUTLETS  IN SUITES 500 AND 600 OF OFFICESPLAN CHK IS FOR TITLE 24 AND 2EA EMERGNCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3443	12041-10000-15235	625 E COLEMAN AVE	90042	14	148-5A231   3	5301011029	[Q]RS-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	2013.02	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.10231	-118.18265	Installation of a fire alarm system in 3 State Approved Modular Buildings.  Building will have to be Re-Approved by the State.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3444	13041-10001-01756	7612 S BOEING AVE	90045	11	099B169  1505	4106008012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			Corrections Issued	07/05/2013 12:00:00 AM	ADDRESS	33.97117	-118.39166	Supplementary: Change of module from REC 245 PE to REC 250 PE. Original description: PHOTOVOLTAQIC SYSTEM FOR SINGLE STORY SINGLE FAMILY DWELLING. USING MICROINVERTER ENPHASE M215-60-2LL-S22. SOLAR PANEL - REC 245 PE. TOTAL 2.216 KW SYSTEM. 10 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3445	12041-10000-05074	300 S FALCON ST BERTH 168	90744	15	024B205    39	7440019001	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			PC Info Complete	04/26/2012 12:00:00 AM	ADDRESS	33.75794	-118.26677	Plan check for new distribution panel and two sump pumps installed at Shell Oil Berth 168. Installation in hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3446	11041-10000-04144	6303 N OWENSMOUTH AVE 6th-floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	06/23/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI IN AN EXISTING OFFICE. EPC IS FOR T24 & LIGHTING. (complete plan check may required by field inspector)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3447	18041-20000-09096	18323 W LABRADOR ST	91325	12	201B125   142	2764003016	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/14/2018 12:00:00 AM	ADDRESS	34.2491	-118.53261	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.2 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3448	12041-10000-12413	111 E UNIVERSAL HOLLYWOOD DR 13TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING EXISTING FLOOR HAVING OFFICES; NEW LOAD IS LESS THAN 400 AMPERES.PLAN CHK IS FOR TITLE 24 AND 1 EACH EMERGENCY LIGHT; ON 13TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3449	18041-20000-18568	550 S PALOS VERDES ST	90731	15	015B201    36	7455026048	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Closed	08/25/2020 12:00:00 AM	ADDRESS	33.73963	-118.28119	Plan check for power only.  Temp power for new construction 1000A Service with the associated load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3450	11041-10000-16135	108 N ROBERTSON BLVD # 108	90048	5	138B169   337	4334002026	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.07561	-118.38359	REMODEL IN EXISTING RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3451	15041-10000-04389	15 N OAKMONT DR	90049	11	135B137   218	4426020002	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Expired	06/29/2017 12:00:00 AM	ADDRESS	34.06742	-118.49114	Power plan check for addition of new screening room and associated power distribution equipment.  New 375 kVA emergency generator, new 800 A service + switchboard, new 15 kVA isolation transformer, and 5 new subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3452	17041-10000-16216	4349 N PERLITA AVE	90039	13	159B205   338	5594003007	RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Issued	05/16/2017 12:00:00 AM	ADDRESS	34.1325	-118.26785	PC for energy only. Outdoor Title-24. Removing existing fixtures and adding new LED lights. Area: 11,375sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3453	18041-10000-33647	601 S FIGUEROA ST 47TH FLR.	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR T24 ONLY, TI ON RESTROOM 47TH FLOOR: NEW PLUMBING, NEW LIGHTING, AND NEW FINISHES. TOTAL AREA: 560 SQ.FT(B# 18016-10000-28409)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3454	14041-20000-23644	7954 N FALLBROOK AVE	91304	12	189B097   463	2013026002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.21517	-118.62317	PV1Install roof-mounted system on SFD, interconnect with MSP. System size: 3.1kW(1) Fronius Galvo 3.1-1 transformer inverter(16) SolarWorld Poly SW250 pv modulesFIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3455	10041-20000-05749	15760 W VENTURA BLVD 920	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	04/22/2010 12:00:00 AM	ADDRESS	34.1552	-118.47684	INTERIOR TENANT IMPROVEMENT TO (E) OFFICE SPACE ( NO CHANGE OF USE).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3456	19041-10000-46844	12326 W RIVERSIDE DR	91607	2	168B165   537	2356034011	R1-1-RIO, R3-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	02/22/2021 12:00:00 AM	ADDRESS	34.15745	-118.40171	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3457	15041-20000-30425	4217 N WOODCLIFF ROAD	91403	4	165A145   107	2281006005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.14709	-118.46753	Installation of new roof mounted solar PV array on existing sigle family home.  Total system size = 6 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3458	15041-20000-36347	7108 N AMIGO AVE	91335	3	183B121   299	2126006015	(T)(Q)RAS3-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.19961	-118.53846	PC FOR POWER AND ENERGY FOR A 4-STORY, 33-UNIT APARTMENT/PARKING GARAGE BUILDING. TOTAL AREA IS 17174 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3459	19041-10000-09659	11035 W OSBORNE ST	91342	7	213B173    64	2529028006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.24	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.28169	-118.37199	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3460	19041-30000-09224	1840 S CENTURY PARK EAST 802/803	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.06188	-118.41473	Plan check for Title 24 only. Project site is an existing suite in a commercial high-rise. Project scope is a tenant improvement. Total lighting area = 3,174 sq. ft.Note: Building application has been generated under 19016-10000-01472	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3461	12041-10000-06371	450 N HIGHLAND AVE	90004	4	141B185  1059	5524032003	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Expired	09/11/2014 12:00:00 AM	PIN	34.0797907	-118.3381933	"New 4.56KW rooftop Photovoltaic system for an existing single family residence with ""Power Boxes"" (DC/DC normalizer).  Misc Permit under Final Fees are for ""Power Boxes"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3462	13041-20000-35061	7468 W BEVERLY BLVD	90036	5	138B181   475	5512008034	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.07597	-118.35294	PC FOR T24 ENERGY ONLY. SHOWROOM FOR FURNITURE STORE. RETAIL USE. LOW LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3463	17041-10000-45107	4141 N WHITSETT AVE	91604	2	165B161   914	2375018020	A1-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.14613	-118.40546	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3464	11041-10000-25936	682 W HARRY BRIDGES BLVD	90744	15	027B205   523	7440006***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	33.77	-118.26886	LEVEL V METHANE MITIGATION SYSTEM FOR YARD OPERATIONS BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3465	11041-10000-09394	6713 S LA TIJERA BLVD	90056	11	102B173   831	4102001028	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			PC Approved	05/10/2011 12:00:00 AM	PIN	33.97875212	-118.37120128	INTERIOR NON STRUCTURAL TI TO 1,000 SF EXISTING RETAIL FOR NEW CIGAR SHOP : EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3466	10041-10000-05825	747 E 10TH ST #108 & 109	90021		124-JA211 185								Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM			PC Approved	03/31/2010 12:00:00 AM	ADDRESS	34.03509	-118.25044	FIRST TENAT IN COMMERCIAL SPACE; TWO EXISTING TENANT SPACES CONVERTING TO 1 EA TENANT SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3467	15041-20000-15229	6316 N TOPANGA CANYON BLVD B1670	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Closed	07/28/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	1st time tenant for Westfield Village. Total area: 2,422 sq ft.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3468	18041-20000-05248	6041 N VARIEL AVE	91367	3	177B105    60	2149005016	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			02/12/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Closed	04/01/2022 12:00:00 AM	ADDRESS	34.1802	-118.59303	New 7-story 274-unit apartment over subterrean parking garage.  3000A 480Y/277V 3ph-4w service. Building permit under 17010-10000-02060.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3469	12041-10000-29940	1322 S WOODRUFF AVE	90024	5	135B157   539	4326014005	R1-1	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.06276	-118.4287	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A TWO STORY BUILDING. USING 1 STRING OF 13 MODULES AND A TRANSFORMERLESS INVERTER. SYSTEM SIZE IS 2.86KW. [INVERTER: SOLAREDGE # SE3000A-US |||| MODULES: KYOCERA # KD220GX-LFBS]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3470	16041-20000-15687	3535 S LA CIENEGA BLVD	90016	10	120B173   388	4205028002	[Q]C4-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Closed	11/01/2017 12:00:00 AM	ADDRESS	34.02292	-118.37248	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (TARGET STORE). SCOPE INCLUDES NEW TRACK LIGHTING. TOTAL AFFECTED AREA IS 1325 SQ. FT. Note: original plan check performed under 15041-20000-37767.  Approved plans lost prior to permit issuance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3471	19041-30000-40107	15164 W OXNARD ST	91411	4	177B145   464	2243019011	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.17918	-118.46392	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to warehouse/manufacturing. Total lighting area = 5,600 sq. ft.Note: Building application has been generated under 19016-20000-17587. Per applicant, no hazardous locations are part of this scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3472	17041-10000-37292	2120 N BEVERLY DR	90210	4	150B161    37	4386016016	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.10999	-118.41899	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.86KWdc / 11.4KWac.(42)MODULES-330W VBHN330SA 16 SANYO PANASONIC(42)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE 11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3473	16041-20000-10324	5447 N WHITE OAK AVE	91316	5	174B129   980	2162016083	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Apartment			03/24/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.16986	-118.51874	Plan check for a PV2 roof-mounted PV system. System size is 18 kWac and consists of (3) inverters, (67) modules, and (1) load center.Note: This PV system is 2 of 2 that will be installed on this building. This system is interconnecting into meter #50434. System 1 can be found under application 16041-20000-10316.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3474	18041-20001-17421	15632 W KINZIE ST	91343	12	201B141   297	2671007013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.24813	-118.4732	Expedite per applicant requestPlan check for PV roof mounted system, system size: 10.6kWac with 35 modules and 2 inverters(7.6kW and 3.0kW) connected to battery backup 9.8kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3475	12041-10000-19312	13190 N BROMONT AVE	91342	7	225B153   419	2509003031	R3-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Apartment			08/16/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.31012	-118.43675	PLAN CHECK POWER AND ENERGY FOR NEW 3 STORY 49 UNITS APARTMENT OVER 1 STORY TYPE  BASEMENT GARAGE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3476	16041-30000-45672	5221 S WESTERN AVE	90062	8	108B193   350	5005030026	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	33.99445	-118.30923	Plan check for a fire alarm system for a 21-unit, 4-story apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (110) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3477	16041-20000-33695	5410 W WILSHIRE BLVD 5th flr	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.06204	-118.34668	TI to an existing commercial office building.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting only.  total square footage 3005.  scope of work in the 5th floor only.Plan check branch circuits on panel p5 per customer request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3478	13041-20000-01506	5343 N ENCINO AVE	91316	5	171B129    34	2257003003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.16848	-118.51441	Roof mounted photovoltaic system on roof of single family dwelling. 5kW Inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3479	12041-10001-11164	700 W WORLD WAY #7G	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	PIN	33.94153561	-118.3984113	DELTA 2, 3, 4, 5 & 6 CHANGES TO THE APPROVED PLANS. REDUCED LIGHTS. ADDED 11 CIRCUITS. RELOCATED ONE PANEL. <<Plan check power and energy for B-Grill restaurant Space#7G Terminal 7.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3480	13041-10000-30038	6841 N MAMMOTH AVE	91405	2	183B153   980	2216024005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.19517	-118.43248	PV1, Install 4.75 kW DC roof-mounted photovoltaic system, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US., power optimizer, and 19 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3481	15041-20000-42818	11456 N PORTER VALLEY DR	91326	12	213B121   479	2822036022	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.2798	-118.55101	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE : 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3482	15041-10000-11212	13400 W REMINGTON ST	91331	7	204B157   822	2646025024	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.25489	-118.4245	PV1, INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, TIE WITH MAIN SERVI E PANEL. (16) MODULES: KYOCERA KU2606XPA, (1) INVERTER: SOLAREDGE SE3800-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3483	18041-20000-44159	20156 W JUBILEE WAY	91326	12	213B113   402	2701087038	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.28237	-118.57354	PV1.  Install 17.5 kW DC roof mounted grid tied PV system.  (50) modules with (2) 7.6 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3484	17041-20001-12006	535 S HOBART BLVD	90020										Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.06424	-118.30551	expeditepv2install roof mounted pv system sized 30kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3485	18041-20000-11577	11400 W OLYMPIC BLVD Suite 840	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.03666	-118.44346	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 877 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3486	19041-10000-41004	1529 W GRIFFITH PARK BLVD	90026	13	144A203    14	5429022005	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	04/08/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.09087	-118.27726	FULL PC FOR CORE AND SHELL SPACE ONLY. SCOPE OF WORK INCLUDES A NEW 600A SERVICE (120/240 3P, 4W) THAT FEEDS A 600A SWITCHBOARD AND ONE NEW SUBPANELS (HP). Full Electrical PC will be required for eachTI. TOTAL AFFECTED AREA IS 4,368 SFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3487	17041-10000-23341	11401 N PORTER RANCH DR BLDG 6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	11/20/2020 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 6 of 10.  Type I.       Building permit #17010-10000-02383	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3488	14041-20000-01145	18436 W DEARBORN ST	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.23719	-118.53469	T24 FOR EXISTING RETAIL STORE. PERMIT HAS BEEN PULLED UNDER APPLICATION#: 13041-20000-36347	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3489	13041-20000-22284	9074 W SHOREHAM DR PV-1	90069	4	144B169   527	5560034008	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.09127	-118.39075	PV-1. MIcroninverters 3.23kW total AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3490	15041-10000-29252	11049 W MAGNOLIA BLVD 400A B	91601	2	171B173   536	2350018085	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.16507	-118.37214	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3491	13041-10002-30034	5532 N MAMMOTH AVE	91401	4	174B157   707	2247001012	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.17124	-118.43219	Expedited RSES plan check per applicant request.(((PV1.  Install 9 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: Fronius IG PLUS V 7.5.  36 modules: Trina Solar TSM-250PA05.18))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3492	15041-10001-38379	4227 S MCLAUGHLIN AVE 1-14	90066	11	111B161   369	4233007007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.00093	-118.41878	Change to approved set by modifying the plan with main scope includes service relocation, fault current and voltage drop calculation. All changes are under delta-C only.Full PC for Newly constructed 14 unit apartment (4 stories). New Service of 1000A 3-Phase 4-wire delta connection. Total sq ft = 15561	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3493	18041-20001-21657	4699 N WHITE OAK AVE	91316	5	168B129   533	2290015022	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.15584	-118.51756	Expedite per applicant request Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (55) modules, and (2) load centers. PV system is interconnecting with a 400-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3494	12041-10000-22439	2735 S MALCOLM AVE	90064	5	123B157   377	4255016004	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.03506	-118.42219	NEW 5.8 KW ROOF MOUNTED PV FOR A SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3495	19041-30000-14783	10000 W PICO BLVD	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.05211	-118.40654	Plan check for Title 24 only. Project site is a new single story accessory structure to an existing country club. Total lighting area = 1,608 sq. ft.Note: Building permit has been issued under 18010-10000-04634	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3496	12041-20000-11621	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Closed	11/06/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	spase #125 / Ritual coffee & wine barEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3497	19041-20000-03407	18535 W BURBANK BLVD	91356	3	174B125   372	2160003004	(T)(Q)R3-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.1725	-118.53724	new fire alarm system 89 devices plus FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3498	13041-10000-02211	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	REMODELING OF OUTFIELD SECTION OF DODGER STADIUM. PC IS FOR POWER AND T24. TOTAL AREA OF 7966 SQ FT. PAVILLION AND BULLPEN OERLOOK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3499	13041-20000-01623	527 S MOLINO ST	90013	14	126A217   220	5163021038	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			01/23/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.04096	-118.23399	"Plan check for power and energy for 68 unit apartment. METHANE ZONE. FIRE ALARM PLANS HAVE BEEN FILED UNDER 13041-20000-01619. EXTRA FEES MAY APPLY FOR METHANE ZONE AND ENERGY PLAN CHECK. Plan check fees subject to verification during ""final"" pay period."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3500	12041-10000-09851	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	"T.I. to an existing retail space at the Grove.  (No tenant number, separate address for each tenant.)  Change to lighting.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit Fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3501	18041-10003-04570	800 S LA BREA AVE	90036	4	132B181   271	5084003001	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Closed	09/10/2020 12:00:00 AM	ADDRESS	34.06027	-118.34454	Change to an approved set by relocating kitchen equipment and adding new ckts on the floor plan. All changes under delta-29 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3502	16041-20000-15603	8537 N KEOKUK AVE	91306	3	192B113   104	2781013014	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM			Reviewed by Supervisor	05/10/2016 12:00:00 AM	ADDRESS	34.22562	-118.57408	Application set to plan check only. Applicant requst to remove appliantion from the system to pull online permit with system less than 10kW instead. {{{{Plan check for PV roof mounted system  SFD. System size: 11.7kW with 49 modules and 49 micro-inverters Enphase}}}}}	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3503	15041-10000-27860	14353 W VICTORY BLVD	91401	6	180B149   829	2237022025	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.18686	-118.44624	Energy plan check for a change of use from retail to office T.I;  Scope includes new lighting and receptacles, total 1458-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3504	14041-10000-17660	727 S CLOVERDALE AVE	90036	4	132B181    66	5089003010	[Q]C2-1-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Verifications in Progress	02/11/2015 12:00:00 AM	ADDRESS	34.06143	-118.34673	PC FOR POWER AND ENERGY. NEW FOUR STORY, 43-UNIT, MULTI-FAMILY HOUSING WITH ONE LEVEL OF PARKING AT GRADE OVER FOUR LEVELS OF SUBTERRANEAN PARKING.  7 TYPES APARTMENTS. TOTAL AREA INCLUDING INDOOR LIGHTING 109872 SQ FT AND OUTDOOR LIGHTING 11523 SQ FT.NUMBER OF DEVICES IS PER CUSTOMER REQUEST.BUILDING APP#: 14010-10000-01857.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3505	17041-10000-12220	6500 S CRENSHAW BLVD	90043	8	105B185  1251	4006015001	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	33.98048	-118.33066	Full plan check to existing building. Change of use from retail to coin laundromat. New service rated at 600 Amps120/240 V 3ph 4wire. All new equipment, New lighting and power. Total area: 11,650.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3506	14041-10000-19989	1400 W SUNSET BLVD	90026	1	138A211    18	5405002033	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Closed	03/05/2015 12:00:00 AM	ADDRESS	34.07427	-118.25235	PLANCHECK FOR T24 ENERGY. CHANGE RETAIL SPACE TO NEW WIRELESS EQUIPMENT ROOM.  820 SQFT, EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3507	10041-30000-04869	6060 W CENTER DR 10th FL	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	05/03/2010 12:00:00 AM		Permit Finaled	07/30/2010 12:00:00 AM	ADDRESS	33.97602	-118.39073	Plan check for T-24 Energy TI on 10th floor of existing high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3508	10041-10000-03806	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM			Not Ready to Issue	03/03/2010 12:00:00 AM	ADDRESS	34.06222	-118.35208	T-24 and emergency lighting plan check only.  No permit to be issued.  Existing permit 10041-90000-02576.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3509	15041-20000-34227	4426 N AUCKLAND AVE	91602	4	165B177   238	2424002011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.15115	-118.36025	Plan check for PV roof mounted system. System size: 11.7kW with 46 modules and 46 micro-inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3510	18041-10000-05346	15725 W PARTHENIA ST	91343	12	195B141   558	2672011043	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.22848	-118.47482	REPLACE OUTDOOR AND INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24 Total sq. ft. 101050	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3511	10041-20000-19457	446 S BROADWAY	90013	14	129A211    68	5149024024	[Q]C4-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	ADDRESS	34.04833	-118.25023	"New fire alarm system.""COMPLY WITH DEPARTMENT ORDER effective date08/03/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3512	12041-10000-22323	11660 W VALLEYCREST ROAD PV1	91604	2	156B169    87	2381018018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.12758	-118.3883	PV-1, SFD ROOF-MOUNTED 12.753KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3513	16041-20000-23302	3116 N JOHNSTON ST	90031	1	141A225    79	5206019005	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.08189	-118.20772	PV1. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.45 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3514	19041-10000-08687	2037 S LA CIENEGA BLVD	90034	10	126B173   885	4302034024	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.03915	-118.37756	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3515	19041-10000-11735	11150 W SANTA MONICA BLVD 8TH FLR	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLAN CHECK FOR TITLE 24 ONLY INTERIOR RENOVATION OF EXISTING RESTROOMS  AREA OF WORK 580 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3516	16041-10000-15366	600 WORLD WAY SPACE 653	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	PROPOSED NEW  INTERNATIONAL CURRENCY EXCHANGE  SPACE  AT CONCOURSE LEVEL 3. PC FOR T-24 ONLY. TOTAL AREA: 121 SQ.FT.B# 16016-10000-08496	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3517	19041-10000-53802	22930 S LOCKNESS AVE	90501	15	045B193   496	7347017028	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	07/18/2020 12:00:00 AM	ADDRESS	33.81656	-118.30418	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3518	18041-20003-35639	2917 W TEMPLE ST	90026	13	139-5A203 445	5156014010	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village	YES	1958.02	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.07449	-118.27896	Revisions to approved set of plans.  Change of interconnection method to feeder tap.  (((Plan check for a PV2 roof-mounted PV system. System size is 21.08 kWdc/20 kWac and consists of (2) inverters, (62) modules, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3519	14041-10000-35093	14006 W RIVERSIDE DR Space #211	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Title 24 plan check only.  Total area = 1,222 sq. ft.T.I. to existing retail space.  Installation of lighting, recepticles, and two 100 A panels.  Tailored method used.  Backroom plan check at request of applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3520	16041-10003-42684	10250 W SANTA MONICA BLVD # 2800	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"""CPK"" plan check only, changes to approved set of plan noted as Delta-10, added receptacle and circuitry for beer pump system. This ckt is covered under permit no. 16041-10002-42684"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3521	19041-10000-11490	1147 S HOPE ST	90015	14	126A207    20	5138014003	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Issued	07/17/2019 12:00:00 AM	ADDRESS	34.04129	-118.2642	New PV2 Rooftop solar system 24 kW AC. Install (99) modules, (2) inverters at 12kW AC each, (1) 100A combiner panel. System connect to (E) 400A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3522	10041-10000-20749	1515 W 190TH ST 2nd & 4th-floors	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	07/01/2011 12:00:00 AM	ADDRESS	33.85852	-118.30531	Tenant improvement on the 2nd and 4th levels of the interior of a  five story office bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3523	13041-10000-26736	14616 W CHASE ST BLDG A	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Info Complete	03/19/2014 12:00:00 AM	ADDRESS	34.22458	-118.45126	Core and shell for 1-story type V-B retail and restaurant.  11,349 sq ft.  BLDG A on submitted electrical plan set.  Tenanta to have their own plan check and permits	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3524	17041-10000-33904	2016 W 65TH PL	90047	8	102B189    43	6016013014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	33.97971	-118.31395	PC for rooftop PV for SFD. Installing 13 new modules and one 3kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3525	13041-10000-24232	920 W BLOOM WALK SSC-2ndfloor	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.01996	-118.28938	PLAN CHECK FOR TITLE 24 PART 6 energy. hi-rise with emergency lighting supplied by generator.CRA CLEARED UNDER 13041-20000-33923. TI TO (E) USC SSC PHYSICS OFFICES. LAB 212 REMODEL. 2nd floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3526	10041-10000-24730	1121-1123 S BOYLE AVE	90023	14	123A221   272		MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	01/07/2013 12:00:00 AM	ADDRESS	34.03075	-118.22046	ALTERATIONS IN THE OFFICES AND SHOWROOM OF A WAREHOUSEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3527	18041-20001-23144	8338 W 3RD ST	90048	5	138B173   876	5511031030	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	34.07268	-118.37138	08-30-18 Changes to an permitted set of plans, changes include down size Fire Alarm Panel Battery from 25Ah to 17Ah battery. Plan check only, permit covered under Master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3528	19041-20000-22600	8401 N VAN NUYS BLVD #15	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.22308	-118.44896	TI to (E) commercial space.  Plan check for energy only. T24 total square footage = 2803 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3529	18041-20000-21285	2503 S HILLCREST DR	90016	10	123B181   690	5057005022	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.03377	-118.3421	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 4.83KVA USING 14 AC MODULES (X21-345-D-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3530	18041-10001-08441	1722 W 51ST PL	90062	8	108B193    42	5003005007	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	33.99587	-118.30763	EXPEDITE PER APPLICANT REQUEST...	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3531	15041-20000-05460	2318 E SUNRISE ST	90023	14	124-5A219 161	5171019***	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.03561	-118.22253	Plan check for Title 24 only. Project is lighting work being done to two rooms of an existing building. Total lighting area = 85 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3532	18041-10000-13942	921 E 8TH ST	90021	14	124-5A213 175	5146029051	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/14/2018 12:00:00 AM	ADDRESS	34.03618	-118.24611	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3533	16041-10000-04820	2133 E VIOLET ST BLDG.C	90021	14	123A217    34	5166003010	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			Re-Activate Permit	05/10/2018 12:00:00 AM	ADDRESS	34.03269	-118.22873	FULL PC FOR AN EXISTING COMMERCIAL BUILDING (BLDG C). AN ADDITION OF MEZZ. TO EXISTING MMANUF. BLDG. AND CHANGE OF USE FROM MANUF. TO CREATIVE OFFICES.  BUILDING 3 OF 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3534	13041-20000-10161	15350 W SHERMAN WAY EAST	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM			PC Info Complete	08/20/2013 12:00:00 AM	ADDRESS	34.20099	-118.46808	New 513kw Photovoltaic system for an existing commercial parking structure.  System is mounted on a carport with new lighting.  Full plan check for Power and Energy. This permit is for the EAST side.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3535	13041-20000-05927	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.23541	-118.47521	New fire alarm system for SIKH Temple.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3536	11041-20000-12649	3458 W WILSHIRE BLVD	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM			PC Approved	06/17/2011 12:00:00 AM	ADDRESS	34.06144	-118.29987	Interior tenant improvements in (E) retail space:  non-bearing partitions and suspended ceiling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3537	11041-10000-04245	6253 W HOLLYWOOD BLVD UNIT 202	90028	13	148-5A189 343	5546030035	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM			PC Approved	03/11/2011 12:00:00 AM	ADDRESS	34.10179	-118.32624	T.I.   TITLE 24 PLAN CHECK ONLY FOR AN OFFICE SPACE (UNIT # 202),   NEW LIGHT FIXTURES (12 RECESSED DOWN LIGHTS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3538	11041-20000-22617	12701 W VAN NUYS BLVD #C	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.02	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM	10/21/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.27621	-118.41056	warehouse/ office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3539	16041-20000-25651	915 W WILSHIRE BLVD 7TH FLR	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI TO AN EXISTING COMMERCIAL BUILDING 7TH FLOOR ONLY.  ADDING NEW LIGHTING NE CONTROLS TO EXISTING PANELS.  PLAN CHECK OR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 6530.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3540	17041-10001-35453	10957 S CENTRAL AVE	90059	15	088-5A209 260	6071020001	MR1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	33.93558	-118.2544	Change to approved set from energy plan check to a full plan check with a new 600-Amp service and lighting plan been modified. Most equiptment has been paid under original application.(((PC FOR TITLE FIRE DAMAGE REPAIR TO (E) COMMUNITY CENTER. FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 7283 SQ.FT SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRUCUITS ANN LIGHTS. )))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3541	17041-10000-33094	4020 S LINCOLN BLVD C	90292	11	108B149  1249	4230002013	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	33.99001	-118.44704	RESTAURANT TI. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3542	16041-20000-35337	9509 N VASSAR AVE	91311	12	198B101    24	2746016062	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.24327	-118.60486	Plan check for energy only. TI to existing office. New lighting (incl. emergency) and receptacles. T24 - 4,825sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3543	19041-10000-32655	5757 W CENTURY BLVD #200B	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	07/19/2020 12:00:00 AM	ADDRESS	33.9457	-118.38274	T-24 PLAN CHECK FOR A TI. SCOPE INCLUDES NEW RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1,245 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3544	12041-10000-02927	23521 W DOLOROSA ST	91367	3	174B093   460	2044006020	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2012 12:00:00 AM	02/24/2012 12:00:00 AM		Issued	02/24/2012 12:00:00 AM	ADDRESS	34.17021	-118.6391	ROOF INSTALLATION OF 8.96KW ,28MODULES PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3545	15041-10000-34277	3131 S HOOVER ST Building 9	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Public Safety Only			10/14/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.02611	-118.28472	NEW FIRE WARNING SYSTEM FOR THE VILLAGE AT USC, BUILDING 9	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3546	13041-20000-05316	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	Install a new 1000 KVA - 4160 volt unit substationon roof to supply two new 480 volt chillers locatied in chilller room.  Also instll new lighting in electrical room.  supply from existing service equipment.AT EXIST 4 STORY PKG STRUCTURE, REINFORCE AND CHECK EXIST SUPPORT FOR REPLACEMENT OF EXIST MECHANICAL EQUIPMENT 3RD FLOOR MECH. EQUIP. AREA  AND NEW MECH. EQUIP AT ROOF LEVEL EXIST MECH. EQUIP. AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3547	13041-10000-35361	656 S AVENUE 61	90042	14	150A233   129	5312026039	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/07/2014 12:00:00 AM	ADDRESS	34.10554	-118.18086	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformerless inverter: Solaredge SE 5000A-US. (18) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3548	14041-20000-09691	13441 W VOSE ST	91405	2	183B157   330	2328017024	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.1986	-118.42614	pv1 single family dwelling. using enphase microinverter. using standard plan. total of 20 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3549	18041-10000-36432	8252 N VAN NUYS BLVD	91402	6	192B149   400	2212004037	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.22127	-118.44856	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3550	10041-10000-15508	4650 W ADAMS BLVD	90016	10	123B181  1023	5050004031	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM			PC Approved	08/09/2010 12:00:00 AM	ADDRESS	34.03237	-118.34186	T.I. to existing building.  All lighting are existing to be remained as shown on plans.   Plan check for energy only.  Permit is under 10041-10K-10646.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3551	17041-10000-38820	13750 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Issued	10/27/2017 12:00:00 AM	ADDRESS	34.30953	-118.43339	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH LED FIXTURES. TOTAL AFFECTED AREA IS 9525 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3552	18041-10000-08139	2833 S WIGTOWN ROAD	90064	5	126B161   581	4318018024	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	01/19/2019 12:00:00 AM	ADDRESS	34.03816	-118.41265	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW ENERGY STORAGE SYSTEMS AND LOAD CENTER. TOTAL SYSTEM SIZE IS 27KWH/14KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3553	11041-10000-16672	421 N HENRY FORD AVE AREA #1	90744	15	027B213     1	7440011270	M3, M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	33.77533	-118.24134	RELOCATE EXISTING DISTRIBUTION TRANSFORMER AND FEED NEW MCC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3554	12041-20000-22918	5641 N COMO CIR	91367	3	174B101  1447	2146035***	(Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2012 12:00:00 AM			Plans on Hold	10/08/2012 12:00:00 AM	ADDRESS	34.17369	-118.61107	Plan check for SFD. 7.92kW. Enphase M215 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3555	16041-10000-43636	6601 N LANKERSHIM BLVD	91606	2	180B169   477	2322018025	C2-1VL, R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.03	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.19059	-118.38798	PC FOR ENERGGY. REMOVE HID FIXTURES AND RPLACE WITH NEW LED FIXTURES. TOTAL (OUTDOOR) AREA 41225 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3556	18041-30000-23879	11640 W SAN VICENTE BLVD Ste. 106	90049	11	129B145    38	4265005033	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.05369	-118.46307	PC for T24 only for TI to (E) retail area and restrooms, Installing new receptacles, lights, equipment in existing panel. Total of 1243sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3557	13041-10001-26192	19440 W ROSITA ST	91356	3	168B117   327	2178014013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.15657	-118.55706	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLARY ARRAY. INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 13kW SYSTEM.52 TSM 250 MODULES. 2 POWER ONE PVI-6000 INVERTERS. UNGROUNDED SYSTEM. 2 STORY HOUSE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3558	10041-20000-05824	6716 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.11785	-118.33896	Installing emergency lighting and exist sign in apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3559	12041-10000-17846	1925 S CENTURY PARK EAST 1260-1280	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.06066	-118.41426	Plan check for energy and emergency lighting. 12th floor of high rise building. 3077 conditioned sqft. Office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3560	19041-20000-07899	19301 W MERRIDY ST	91324	12	204B117   564	2726019011	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	34.25194	-118.55402	PLAN CHECK FOR NEW 13.05KW DC/12.6KW AC ROOF MOUNTED PV SYSTEM FOR EXISTING SFD, SCOPE OF WORK INCLUDES (1) 100A LOAD CENTER, (45) REC SOLAR REC290TP2 PV MODULES, (1) NINGBO GINLONG TECHNOLOGIES SOLIS-1P3.6K-4G-US INVERTER, AND (1) NINGBO GINLONG TECHNOLOGIES SOLIS-1P9K-4G-US INVERTER. MAIN BREAKER IS BEING DERATED FROM 200A TO 175A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3561	15041-20000-06686	1314 N AVENUE 55	90042	14	156A227   430	5478025020	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.1202	-118.198	Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  16 modules with miroinverters on 1 branch circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3562	13041-20000-14234	5900 W WILSHIRE BLVD 15th floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM			PC Approved	06/04/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE 15TH FLOOR. 2319 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3563	17041-10000-44176	1840 S CENTURY PARK EAST	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.06188	-118.41473	PC for T24 only for outdoor lighting on roof deck on 2nd floor. Total area 242sqft. B 15014-10000-04892.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3564	17041-10000-15714	3154 E OLYMPIC BLVD	90023	14	118-5A223  45	5190027002	M1-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.01998	-118.21073	T24 ONLY. REPLACE EXISTING HID LIGHT FIXTLURES WITH NEW LED LIGHT FIXTURES. TOTAL ARE  A  4800 SQ FT. OUTDOOR  LLIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3565	15041-10000-40746	1440 S SEPULVEDA BLVD 2ND FLOOR	90025	5	129B149    38	4324016094	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.05107	-118.44699	T24 FOR EXISTING LOW RISE OFFICE BUILDING. SCOPE OF WORK ON THE 2ND FLOOR NORTH PART. 12500 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3566	16041-20000-21409	19754 W WINGED FOOT WAY	91326	12	216B117   141	2701026007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.28754	-118.56446	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3567	19041-10000-46865	20481 W NASHVILLE ST	91311	12	210B109   131	2707026034	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.27029	-118.57943	PV1, NEW ROOFOPT MOU NTED SYSTEM, SYSTEM SIZE IS 30 MODULES (CANDIAN SOLAR) WITH OPTIMZERS (SE P370), LEADING TO A CENTRAL INVERTER (SE7600H-US). NO MAIN PANEL UPGRADE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3568	13041-20001-22472	2219 E 15TH ST	90021	14	120A217   162	5167011041	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Info Complete	12/12/2013 12:00:00 AM	PIN	34.02225397	-118.23278559	New 1600 A service and equipment for an existing industrial area ((((changes to approved set of plans. revised a panel to a lesser rating and added a new distribution. plan check for clouded delta 1 changes only. )))) ((motors are counted for building wiring.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3569	19041-10000-52738	1377 N SERRANO AVE	90027	13	147A193   488	5544032020	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	06/25/2020 12:00:00 AM		Permit Finaled	05/12/2021 12:00:00 AM	ADDRESS	34.0965	-118.30717	FULL PC, SCOPE OF WORK IS A TI NEW PANELS, CIRCUITS AND LIGHTING. TWO NEW 400A DISTRIBUTION BOARDS FEEDING SUBPANELS, AND TWO NEW 75 KVA TRANSFORMERS. TOTAL NEW CONNECTED LOAD IS OVER 400A. TOTAL AFFECTED AREA IS 12,100 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3570	18041-20001-30110	5455 W HOLLYWOOD BLVD	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	34.10193	-118.30881	01-16-2018 Changes to an approved set of plan, changes include service entrance conductor tap from4,000A 277/480V distribution, tap ahead of the main disconnect. All changes has been clouded on delta 5. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3571	11041-20000-07041	4211 N EAGLE ROCK BLVD	90065	14	156A219   107	5473024024	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.00	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM	06/10/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.12229	-118.22486	New P.V. system with 90.16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3572	18041-10001-16284	11435 W BIONA DR	90066	11	114B157   377	4234008039	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	ADDRESS	34.01082	-118.42311	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF SOLAR PANELS. ORIGINAL PERMITPLAN CHECK FOR ROOF MOUNTED PV SYSTEM(3.8KVA) CONSISTING OF 1 CENTRAL INVERTER SE3800H-US WITH 15 PANELS USING P320 POWER OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3573	12041-10000-25469	331 S LA BREA AVE	90036	4	135B181   271	5508001009	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.06796	-118.34422	reason for PC : inspector sent back for T24. Approved.PC FOR T24 ONLY. EXISTING SPACE TO BE FURNITURE SHOWROOM. WE CALCULATED OCCUPANT LOAD TO BE AROUND 181 (EMERGENCY LIGHTING REQUIRED). 10010 SF. SINGLE BUILDING WITH MEZZANINE. METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3574	13041-10000-08528	8550 N BALBOA BLVD SUITE 150	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.22649	-118.5024	RENOVATION OF EXISTING OFFICES. NEW CIRCUITS AND WIRING. NEW CONNECTED LOAD > 400A. FULL PLAN CHECK FOR POWER AND ENERGY. TOTAL AREA 35179 SQ FT. NON MEDICAL. WORK DONE IN SUITE 150.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3575	12041-20000-01199	6102 1/2-6104 N LANKERSHIM BLVD	91606	2	177B169   518	2338005008	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM			PC Approved	01/18/2012 12:00:00 AM	ADDRESS	34.1814	-118.38438	Combine two retail spaces into one and change of use from retail to Little Caesar take-out pizza restaurant ( 1470 sf )ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3576	16041-20000-28411	947 N WILCOX AVE	90038	13	144B185   995	5533022003	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			08/10/2016 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.08844	-118.33125	Plan check for power and energy. New 4-story 7-unit apartment building. 600A service. Fire alarm variance NOT yet filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3577	14041-10004-00855	6417 W SELMA AVE	90028	13	148-5A187 302	5546007022	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.09988	-118.33008	01/18/16Changes to an approved set of plans. Scope includes adding new panels, and new circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3578	19041-20000-32285	12610 W SATICOY ST SOUTH	91605	2	186B161   512	2324002020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.20519	-118.40807	T.I. PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3579	15041-10001-30289	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	34.01318	-118.34004	7/12/16: Revision to approved set noted under Delta -1 and Delta- 1C.  Revise lighting plan & outdoor light. fixture schedule, single line diagram, Isc calculation, Buil. load calc., Rearrange branch circuits. <<New 4-stories Kaiser Permanente Medical Office BuildingNOTE THAT ITEM QUANTITIES SUBMITTED BY APPLICANT>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3580	14041-10000-15469	6118 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.0978	-118.32305	NONSTRUCTURAL INT REMODEL - COMBINE EX RETAIL & RESTAURANT TENANTS INTO ONE RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3581	13041-10000-33112	1925 S CENTURY PARK EAST	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLAN CHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT ON HIGH RISE OFFICE SUITE #720. 2531 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3582	14041-20000-31287	8443 W FOOTHILL BLVD	91040	7	207B189  1094	2555025007	C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	34.25987	-118.31721	T.I. to existing building.  Install general/emergency  indoor and outdoor lighting.  Plan check for energy only.Note: Permit is under separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3583	16041-20002-24899	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM			PC Info Complete	01/31/2017 12:00:00 AM	ADDRESS	33.93576	-118.3779	01/24/2016 Changs to an approved set of plans. All changes have been clouded and marked as Delta 7. There has been an addition of a subpanel and load and changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.9.1.2016 - Plan check for modifications to approved set. Showing existing panels on SLD and available fault current at each. Replacing existing panels with ones of higher fault current rating where available fault current is >10kAIC -- using series ratings. Provide floor plan to show existing panel locations. Changes clouded delta 6.======Plan check for power and energy Change of use from retail to a restaurant service upgrade 2000 A Service and new panels with some exiting load. Total area: 19,843 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3584	16041-20000-02542	21155 W CALIFA ST	91367	3	177B105   104	2149002026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.17716	-118.59277	Plan check for Title 24 only T.I. existing building. Total area: 14,556 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3585	15041-10000-02143	831 N COOPER AVE	90042	14	156A233   256	5716011002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.12137	-118.17448	PV system size: 11kW. 2 inverters (6000W and 5000W), 33 modules (18 and 15). 60A subpanel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3586	15041-20000-33962	117 S BOYLE AVE	90033	14	129A221   263	5174013904	C2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.04687	-118.22011	FIRE ALARM SYSTEM FOR 80 UNIT APARTMENT. TOTAL SYSTEM SIZE 276 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3587	15041-10000-04295	2723 W 8TH ST	90005	1	132A201    11	5077020802	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.05787	-118.28484	Plan check for fire alarm system. 74 SD and 64 Fire alarm devices and 1 fire alarm panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3588	15041-20000-12045	5182 N BRIAN LANE	91436	5	171B137    99	2260017040	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.16456	-118.48738	PV1 SFD. TOTAL SYSTEM SIZE 8.8 KW AC USING MICROINVERTER SYSTEM. USES ENPHASE M250. TOTAL OF 37 MODULES.SYSTEM USES STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3589	17041-30000-45517	1403 N WILMINGTON BLVD	90744	15	036B201   762	7414024029	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	33.79069	-118.27518	Plan check for Title 24 only. Project site is an existing commercial minimart. Project scope is an addition to the minimart. Total lighting area = 271 sq. ft.Note: Building application has been generated under 17014-40000-05180. Per applicant, scope of work is out of all hazardous locations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3590	14041-10000-17133	4909 S CRENSHAW BLVD	90043	8	111B185   464	5013017024	[Q]R4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	33.99795	-118.33124	PLAN CHECK FOR POWER AND ENERGY. TOTAL AREA 8500 SQ FT.  CHURCH PLACE OF ASSEMBLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3591	19041-10000-14504	3201 E UNION PACIFIC AVE	90023	14	118-5A223 193	5169001014	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Issued	06/04/2019 12:00:00 AM	ADDRESS	34.01715	-118.21064	NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (3) SE5000H INVERTER AND (52) MODULES + OPTIMIZERS. TOTAL SYSTEM SIZE IS 20.54KWDC AND 15KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3592	19041-20000-01866	23367 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	34.15846	-118.63421	Void: Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to office. Total lighting area = 2,336 sq. ft.Note: Building application has been generated under 19016-20000-01372	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3593	18041-10000-48331	1900 W 3RD ST	90057	1	133-5A205  78	5154027029	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			12/20/2018 12:00:00 AM	05/29/2020 12:00:00 AM		Permit Finaled	09/14/2023 12:00:00 AM	ADDRESS	34.06186	-118.27049	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW PANELBOARDS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 5602 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3594	18041-10000-32309	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			Verifications in Progress	03/19/2019 12:00:00 AM	ADDRESS	34.16326	-118.37388	NEW GROCERY STORE. PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT: 18016-10000-27289	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3595	14041-10000-23980	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.14441	-118.39252	NEW 800AMP SERVICE FOR 5 STORY TYPE2A OFFICE AND GARAGE BUILDING.(2 STORIES PARKING, 3 STORIES OFFICES.PLAN CHECK FOR POWER AND ENERGY.PLAN CHECK IN ACCORDANCE TO 2008 ENERGY EFFICIENCY STANDARDS DUE TO BUILDING SUBMITTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3596	18041-10001-19781	222 W 6TH ST 1-10	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	33.73887	-118.28305	Change to approved set with new fault current update. all fault current and voltage drop shall be rechecked.(((PC FOR RESTAURANT TI   FOR FIRST TIME TENANT RESTAURANT. SCOPE INCLUDES NEW LIGHTS EQUIPMET AND RECEPTACLES. TOTAL AFFECTED AREA 2637 SQ. FT. B# 18016-10000-16852 )))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3597	16041-10003-26342	10400 S AVIATION BLVD	90045	11	090B173   318	4129034001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	33.94154	-118.37829	DELTA 28 CHANGES TO THE APPROVED PLANS.<<<<CHANGES  INCLUDE COMPLETE FEEDER SIZING, REPLACING FEEDER BREAKER, REVISING VOLTAGE DROP, LOAD CALCULATIONS, SIGHT LIGHTING, ADDING NEW TRANSFORMER, AND ONE NEW AIR COMPRESSOR.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3598	15041-20000-19553	6250 N TOPANGA CANYON BLVD F-1560	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for power and Title 24.  Total area = 1,850 sq. ft.  T.I. to existing commercial first time tenant.  New lighting and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3599	16041-20000-26827	7140 N SALISBURY ROAD	91307	12	183B089    34	2028039045	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.20126	-118.65249	Plan check for PV roof mounted system. System size: 8.0kW with 25 AC Modules. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3600	16041-20001-21032	6517 N VARNA AVE	91401	2	180B157   654	2329017012	RS-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.18892	-118.42483	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.07KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3601	19041-10000-02989	824 W VENICE BLVD	90015	1	126A203   196	5135029015	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.03932	-118.27481	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING CHURCH UPGRADING TO 400A PANELBOARD FULL PLAN CHECK MAY REQUIRE PER INSPECTION. SCOPE INCLUDES APPROXIMATE 4880 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3602	11041-10000-26869	20661 W SATICOY ST	91306	3	186B109   232	2108025032	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2011 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	02/17/2012 12:00:00 AM	ADDRESS	34.20846	-118.58382	Plan check roof mounted 7.05KW Enphase M215 microinverter photovoltaic system for single family dwelling.  Additional permit for installation not covered on previously issued permit 11041-10000-24541	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3603	17041-10000-16461	3640 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM			PC Info Complete	06/21/2017 12:00:00 AM	ADDRESS	34.01993	-118.37802	PC FOR POWER AND ENERGY FOR AN OFFICE TI (SINGLE STORY).TOTAL CONNECTED LOAD >400ATOTAL AFFECTED AREA  24,408 SQ (TITLE 24 FORMS TO BE UPDATED)SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT, PANELS.BL# 17041-10000-12131	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3604	12041-10000-20584	3848 N LANKERSHIM BLVD	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Closed	12/24/2012 12:00:00 AM	ADDRESS	34.13848	-118.36213	remodeling of existing office on the 5th floorplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3605	14041-10000-17662	8806 S SEPULVEDA BLVD	90045	11	096B165   971	4123001002	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	03/20/2015 12:00:00 AM		Issued	03/20/2015 12:00:00 AM	ADDRESS	33.95688	-118.39597	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. CHANGE OF USE OF EXISTING PORTION OF RETAIL TO  RESTAURANT & REMODEL.BUILDING P # 14016-10000-08518.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3606	15041-20001-36207	700 WORLD WAY SPACE 7C	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	Changes made to approved plans.  Changes to lighting design, minor changes in location of some equipment.    (((PROPOSED TENANT IMPROVEMENT FOR  CHANGE OF USE FROM  FOOD & BEVERAGE CONSSECION TO RETAIL PREPACKAGE FOOD.PC for Power and Energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3607	14041-20001-00507	8434 N GLASSPORT AVE	91304	3	192B105   363	2779012047	R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.2231	-118.59382	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 7.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3608	15041-10000-19478	6333 N WOODMAN AVE	91401	2	180B157  1062	2239006009	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Apartment			06/29/2015 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.1858	-118.43144	PLAN CHECK FOR POWER AND ENERGY FOR NEW 4 STORY 49 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3609	17041-20003-30118	13951 W ENADIA WAY	91405	2	183B153   197	2216006008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	34.2004	-118.43747	[[12/05/17 CHANGES TO APPROVED SET. DELTA 2 CHANGES ARE CLOUDED. PLANCHECK ONLY.  ADDING DISCONNECTS. ]]]]]Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (43) modules, (1) load center, and (2) Tesla Powerwalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3610	18041-20000-34896	9852 W NATIONAL BLVD	90034	5	123B165   967	4311005014	C2-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.03087	-118.40141	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is outdoor lighting. Total lighting area = 20,316 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3611	16041-10002-30867	5132 N EL RIO AVE	90041	14	163-5A221 309	5671016019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Apartment			08/30/2016 12:00:00 AM			PC Approved	09/23/2016 12:00:00 AM	ADDRESS	34.1405	-118.21606	Expedite Fees per customers request.PC for new PV solar system with 41 modules, 1 SB7700TL inverter rated at 7680W,1 SB5000TL inveter rated at 5000W and 1 load center. Installing modules in front of housewith main panel located in backhouse.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3612	18041-10001-20095	8811 W BURTON WAY	90048	5	138B169   687	4334011063	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM			PC Approved	06/14/2019 12:00:00 AM	ADDRESS	34.07249	-118.38417	Plan check for Title 24 Energy only for a lost set of plans. Total affected area is 4775 sq ft.Note: Permit is under master application 18041-20000-20095. PC Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3613	17041-10000-01330	523 W 6TH ST SUITE 210	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24, PC FOR ENERGY ONLY FOR A FITNESS CENTER ON THE 2ND FLOOR OF AN EXISTING COMMECIAL BUILDING. SCOPE INCLUDES ONE NEW PANEL, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 4660 SQ. FT. A3-OCCUPANT LOAD IS 69 OCCUPANT < 100.  B#16016-10000-28773.**SEE APPLICATION COMMENTS**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3614	19041-10000-02782	8247 N LAUREL CANYON BLVD	91605	2	192B165   898	2309029030	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.22105	-118.39677	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3615	12041-10000-04864	635 W USC MC CARTHY WAY EVK BLDG	90089	8	120A201    87	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	07/30/2012 12:00:00 AM	ADDRESS	34.02103	-118.28214	PLAN CHECK POWER AND ENERGY REMODEL OF EXISTING DINING HALL AND KITCHEN ON GROUND FLOOR OF 4 STORY RESIDENCE HALL AT USC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3616	17041-10000-04420	7063 N LAUREL CANYON BLVD	91605	2	183B165   134	2321005906	PF-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.19918	-118.39671	PC for outdoor Title 24. Removing HID lighting fixtures and replacing them with new LED lighting fixtures. Area: 69,750 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3617	17041-10000-42954	444 N MCCADDEN PL	90004	4	141B185  1065	5524033004	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.07958	-118.33713	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL BUILDING. TOTAL SYSTEM SIZE IS 5.0KWac.(17)MODULES-LG350Q1K-A5(17)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE5000H-USINSPECTOR TO VERIFY THAT SCCR OF DISCONNECT SWITCH IS 22KA MINIMUM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3618	16041-20001-17873	3833 N WINFORD DR	91356	3	162B121    39	2177047022	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	ADDRESS	34.14068	-118.55007	EXPEDITE PER PPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 21KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3619	19041-30000-05793	1539 S PURDUE AVE	90025	11	129B149   497	4261003009	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.04616	-118.45131	Plan check for a fire alarm system for a 6-story mixed-use building. Fire alarm system consists of (1) FACP and (143) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3620	13041-10000-15496	355 S GRAND AVE FL 28,29-FL 30	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.05191	-118.2525	APPLICATION PC# WILL BE FOR BOTH PLAN CHECK AND ISSUING OF THE PERMIT.REMODELING OFFICES ON THE 28TH;29TH AND 30TH FLOORSPLAN CHK IS FOR TITLE 24 AND 3 EA EMERGENCY CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3621	16041-10000-09526	8407 W MELROSE PL	90069	5	141B173   440	5528002029	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.08377	-118.37342	T-24, TI TO A RETAIL STORE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACELS. TOTAL SQ. FT. 1253.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3622	13041-20001-05024	1800 N CAMINO PALMERO	90046	4	150B181   697	5572029013	RE9-1	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2013 12:00:00 AM			Verifications in Progress	03/19/2013 12:00:00 AM	ADDRESS	34.10368	-118.35012	Modification to previously approved set of plans.  Install new PV load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3623	10041-20001-24242	11055 W CUMPSTON ST	91601	4	174B173  1242	2350003009	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			03/01/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.17012	-118.37213	"Plan check extension variance has been filed. Original approval is on 10041-20000-24242; permit is on this application. /////////////////Permit is under ""inspection"" fee period.///////////////////////////////////////////////////////////////////////////////////////////////Expiration of Plan check. Resubmittal. PLAN CHECK FOR NEW 25 UNIT APARTMENT BUILDING WITH 1600A SERVICE. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3624	11041-20000-10524	5700 W WILSHIRE BLVD #380	90036				QC4-2-CDO		Wilshire	Mid City West			Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM			PC Approved	05/23/2011 12:00:00 AM	ADDRESS	34.06218	-118.35303	PLAN CHECK T24 ENERGY LIGHTING AND EMERGENCY FOR TENANT IMPROVEMENT SUITE #380 CORRIDOR AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3625	19041-20002-29368	11957 N LOUISE AVE pv1	91344	12	216B129   212	2606026033	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM			Reviewed by Supervisor	08/06/2019 12:00:00 AM	ADDRESS	34.28854	-118.51244	expeditepv1install ground mount pv system sized 15.2KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3626	19041-10000-52702	19510 W VENTURA BLVD	91356	3	174B117   326	2164016028	QC2-1VLD, QP-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	06/03/2021 12:00:00 AM		Permit Finaled	08/15/2022 12:00:00 AM	ADDRESS	34.1726	-118.55833	FULL PC PER APPLICANTS REQUEST, SCOPE OF WORK IS A RENEVATION PROJECT, SCOPE INCLUDES A NEW PANEL CONNECTED TO AN EXITSING 1200A SWITCHBOARD (208/120), 3P,4W). TOTAL AFFECTED AREA IS 47,740 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3627	14041-20000-02307	16300 W STAGG ST	91406	6	189B137    70	2205004031	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.21296	-118.48748	T24 FOR EXISTING RETAIL STORE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3628	10041-10000-17501	425 S PALOS VERDES ST 5th floor	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM			PC Info Complete	09/09/2010 12:00:00 AM	ADDRESS	33.74102	-118.28156	T-24 energy compliance and emergency lighting for a portion of the 5th floor.- open offices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3629	15041-20000-16623	15301 W VENTURA BLVD #210, 210A	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for office T.I. Replace fluorescent and incandescent light fixtures to LED light fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3630	12041-20000-03943	11558 W TENNESSEE AVE	90064	11	123B153   336	4260024001	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.03429	-118.44377	Roof mounted P.V. system with 11.28Kdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3631	14041-20000-21586	1680 N VINE ST 1200	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	INTERIOR TI FOR SUITE 1200 (4822 SF), NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3632	14041-20000-24830	7010 S HOOVER ST Unit #1	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #1. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3633	16041-10001-03316	1663 W 204TH ST # D	90501	15	054B193   121	7351005002	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	33.84588	-118.3088	03/08/2016PC ONLY TO CHANGE THE CONDUIT LENGTH. NOTE CHANGES ON DELTA 1. (((PV1,  ROOF-MOUNTED SOLAR ARRAY SIZED 3.0KW  ON A SINGLE FAMILY HOUSE.(8) MODULES: KYOCERA KU255-6XPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3634	15041-30001-42268	7168 N SALE AVE	91307	12	183B097   884	2024040026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.20078	-118.61891	Expedite fees only.Addition of new roof mounted solar PV array to existing roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac (3 kWac new).  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3635	10041-10000-23881	1622 E OLYMPIC BLVD	90021	14	123A213   329	5130004016	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Public Safety Only			12/01/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.02947	-118.24141	INSTALLATION OF FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING  IN AN OFFICE/WAREHOUSE  BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3636	16041-10000-16078	820 S SPRING ST	90014	14	127-5A211 243	5144016047	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			05/06/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.04255	-118.25395	APPLICATION IS FOR PLAN CHECK ONLY; INSTALL A FIRE ALARM SYSTEM FOR THE FACILITY. 3 stories, 7 units appartment. permit already issued under12041-10000-12123. Original plan check number: 12041-10000-15655.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3637	14041-10001-34867	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM			PC Approved	03/17/2015 12:00:00 AM	ADDRESS	34.05069	-118.24861	Change to approved set by replacing fixture B, and adding fixture C and D.(((Title 24 plan check only.  Total area = 700 sq. ft. Lighting T.I. to existing restaraunt space.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3638	19041-10000-36654	1601 S CRENSHAW BLVD	90019	10	126B185   192	5071001042	C2-2D-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.04451	-118.32886	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LED LIGHTING (REPLACING FLUROSCENT LIGHTS), AND NEW CONTROLS IN A EXISITING BUILDING. TOTAL AFFECTED AREA IS 882 SQFT. B# 19016-10000-13149	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3639	13041-10000-35975	419 S SPRING ST	90013	14	129A211    54	5149024016	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM			Reviewed by Supervisor	03/04/2014 12:00:00 AM	ADDRESS	34.04843	-118.24885	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE FROM OFFICES TO HOTEL. ESTIMATING SQFT 75000( LTG FORMS MISSING)BUILDING PERMIT : 13016-10000-26325. ADAPTIVE  REUSE OF  AN EXISTING OFFICE BUILDING TO BE CONVERTED TO A 185 ROOM  HOTEL .   CHANGE  OF  USE FROM  OFFICE  TO  HOTEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3640	19041-20000-19194	18517 W VENTURA BLVD	91356	3	174B125   577	2160007034	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM			PC Info Complete	09/06/2019 12:00:00 AM	ADDRESS	34.16926	-118.53663	T24 ONLY PLAN CHECK. TI REMODEL TO EXISTING RESTAURANT. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2754.4SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3641	17041-20000-04646	18928 W VICTORY BLVD	91335	3	180B121   606	2128005044	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.18641	-118.5459	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.24KW.  ADDITION  TO EXISTING SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3642	17041-20001-34496	12354 W HUSTON ST	91607	2	168B165   266	2356029002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.15929	-118.4027	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.3.8kW ungrounded pv system. (12) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3643	16041-20000-32550	14521 W SHERMAN WAY	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.20136	-118.44968	TI TO AN EXISTING COMMERCIAL BUILDING (PAPA JOHNS).  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTIG PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3644	11041-10000-15646	3785 W WILSHIRE BLVD #24 & 25	90010	10	132B193    30	5503030903		Central				2118.02, 2125.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	34.06187	-118.30858	TENANT IMPROVEMENT OF NEW REVOLVING SUSHI RESTAURANT IN FIRST FLOOR OF EXISTING BUILDING.  CHANGE OF USE RETAIL TO RESTAURANT @ 1ST STORY OF 7 STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3645	12041-10000-06012	1655 N MCCADDEN PL	90028	13	148-5A185 184	5547012014	C2-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.10078	-118.33708	New Fire Alarm system in an existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3646	13041-20000-17237	11951 W ANETA ST	90230	11	105B161   207	4220009018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	33.9866	-118.40743	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW USING MICROINVERTER ENPHASE M215. TOTAL OF 27 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3647	13041-20000-12938	6518 N MATILIJA AVE	91401	2	180B153   767	2238012004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.18904	-118.4333	PV1 ONE STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.464 KW. 32 MODULES, AND 2 INVERTERS. [INVERTER: (1) POWER ONE PVI-6000-OUTD-US (1) PVI-3.6-OUTD-US] [SOLAR MODULE: SUN POWER SPR-327NE]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3648	14041-20001-05294	22101 W LONDELIUS ST	91304	12	195B101   253	2010007020	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.22941	-118.60836	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3649	16041-20000-12918	12609 N EL ORO WAY	91344	12	219B133   177	2608005007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.29941	-118.50698	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. PV addition system size is 3 kWac and consists (1) inverter and (8) modules. Total system size 9 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3650	14041-10000-16298	7283 N BELLAIRE AVE	91605	2	186B161   550	2324004001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.20324	-118.40954	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3651	14041-10000-35657	2121 S AVENUE OF THE STARS 31st FL	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check for energy T.I.  in tenant space in the existing building. Total square footage: 12693SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3652	18041-20000-03679	12143 N DELANTE WAY	91344	12	219B125    73	2601073004	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.29421	-118.5277	PV1.  Install 3.8 kW roof mounted PV system with (14) modules and 13.5 kWh energy storage system on 300A rated 240/120V residential service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3653	19041-20000-10467	1950 S NORMANDIE AVE	90007	1	126B197   858	5075029012	R3-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Apartment			03/22/2019 12:00:00 AM	10/15/2020 12:00:00 AM		Permit Finaled	05/12/2022 12:00:00 AM	ADDRESS	34.03872	-118.30013	FULL PLAN CHECK FOR NEW 800A SERVICE, T24 TOTAL SQUARE FOOTAGE = 7920.6SF. 4 TYPICAL UNITS,B#18010-10000-01200	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3654	14041-10000-16675	455 S MCCADDEN PL	90020	4	135B185   366	5507014013	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.06527	-118.33729	""" Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0. ""PV1 17KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(3) inverters: {SMA: (1) SB 2500US & (2) SB 6000US}]. [(68)modules: {SMX CAPITAL ZHM250P }]"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3655	15041-10000-31043	6442 N COLDWATER CANYON AVE #101	91606	2	180B161   952	2325031009	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.18794	-118.41362	T-24, install new lighting fixtures in an office building. Total area: 2336 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3656	15041-20001-21205	23041 W ERWIN ST	91367	3	177B097   217	2039010004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM			Reviewed by Supervisor	07/15/2015 12:00:00 AM	ADDRESS	34.18294	-118.62923	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. 9KW DC.  CENTRAL INVERTER. NON STANDARD PLAN.34 KYOCERA KU 265 MODULES1  FRONIUS PRIMO 7.6KW INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3657	19041-10000-18969	1262 E PALMETTO ST 1ST FLR-STE 515	90013	14	126A217    44	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.04005	-118.23347	FULL PC (PWR AND ENERGY) FOR FIRST TIME USE OFFICE/RETAIL -  SCOPE INCLUDE ADDING NEW PANEL , EXISTING SERVICE IS 1600A,277/480V. AREA OF SCOPE IS 9,645SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3658	16041-20001-26776	1550 N POINSETTIA PL	90046	4	147B181   464	5548010017	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	11/22/2016 12:00:00 AM	ADDRESS	34.09956	-118.34773	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 40 kWac and consists of (4) inverters, (176) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3659	16041-20000-23821	16830 W VENTURA BLVD SUITE 508	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.15886	-118.50032	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES IN HIGHRISE.  SUITE 508. 1190 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3660	16041-10001-40592	29050 S WESTERN AVE #100	90732	15	021B193    39	7445004242	(Q)C2-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	09/14/2022 12:00:00 AM	ADDRESS	33.7545	-118.30904	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING RESTUARANT SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1404 SQ. FT. B#16016-10000-27586	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3661	15041-10000-04153	333 N BREED ST 1-4	90033	14	129A223   146	5175011007	R3-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			02/11/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.04829	-118.20842	Installation of new central station fire monitoring system.  5 devices + 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3662	19041-10000-25386	811 W 7TH ST 4TH FLR	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.04908	-118.25911	T-24, PC FOR ENERGY ONLY. TI OF 4TH FLOOR ONLY. TI FOR AN AN OFFICE SPACE ON THE 4TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 7,800 SQ. FT. B#19016-10000-19849	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3663	19041-10000-50338	1483 S ALAMEDA ST	90021	14	120A215   115	5167018029	M3-1	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.02378	-118.23946	PLAN CHECK ONLY FOR T24, ALL PERMIT FEES HAVE BEEN PULLED UNDER 18041-70000-34581. SCOPE OF WORK IS NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 1037 SQFT.  NO HAZARDOUS AREASEXPRESS PERMIT (18041-70000-34581)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3664	19041-20000-22547	17624 W CORINTHIAN DR	91316	5	168B129   347	2290011045	RE11-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.15819	-118.51713	$0 permit fee due to SB1222 and AB1414EXPEDITED PLAN CHECK FOR NEW PV AND ESS FOR EXISTING SFD. PV SYSTEM SIZE IS 13.86KW DC/13.23KW AC. ESS SYSTEM SIZE IS 27 KWH. SCOPE OF WORK INCLUDES (42) PANASONIC PV MODULES WITH (42) ENPHASE IQ7X MICROINVERTERS, (2) 13.5 KWH TESLA POWERWALLS, A ENPHASE AC COMBINER BOX, A 200A SUB PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3665	10041-10000-06245	610 E 7TH ST	90021	14	126A213   206	5146033036	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/29/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	34.04022	-118.24654	NEW 600 AMPS SERVICE FOR A WARE HOUSE , NEW PANEL, FUTURE HOT WATER AND AC AND EXISTING RECEPTACLE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3666	13041-10000-01568	334 E 2ND ST A-B	90012	14	129A215   104	5161020018	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	01/22/2013 12:00:00 AM	ADDRESS	34.0484	-118.24081	TI TO EXISTING OPTOMETRY OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3667	13041-10001-28789	16745 W TIM LANE	91406	6	180B137  1008	2231018***	RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.19363	-118.49846	][][]EXPEDITED PER APPLICANT REQUEST [][[]PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A 2-STORY HOME. INTERCONNECTING WITH (E) 200A MAIN SERVICE. SYSTEM IS XFORMERLESS, WITH (17) MODULES: TRINA SOLAR #TSM-250PA05.18(1) SOLAREDGE #SE3800A-US(17) SOLAREDGE OPTIMIZERS: POWERBOX, 250W, #OP250-LV-MC4SM-2NA-Z	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3668	15041-10004-14620	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	02/28/2017 Changes to an approved set of plan. Changes include feeder size revision under delta 38 and relocation of 800A  switch gear (2HGP2 AND 2HGP1) Changes has been clouded as delta 38. This is revision under package 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3669	17041-10000-41105	6221 W HONOLULU AVE bldg 1	91042	7	195B205    43	2572005018	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.23218	-118.26722	replacing outdoor luminaires with led typePLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3670	17041-20001-21194	17080 W GOYA ST	91344	12	222B133   343	2602022002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	ADDRESS	34.30446	-118.50392	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.New 3kW ungrounded system w/ (9) 290W pv modules, adding to existing 3.6kW ungrounded pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3671	16041-10000-43469	11812 W SAN VICENTE BLVD STE 380	90049	11	129B145   113	4265018016	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.0528	-118.4684	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE ON THE 3RD FLOOR(SUITE 380). SCOPE INCLUDES REPLACING 6 LIGHTING FIXTURES. TOTAL AFFECTED AREEA IS 430 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3672	17041-20000-39623	9841 N AIRPORT BLVD 7th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Issued	11/02/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3673	16041-10001-35353	6750 N DE SOTO AVE	91303	3	180B109    39	2148006023	C1.5-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.19316	-118.58808	PC FOR CHANGES TO APPROVED SET. THIS IS ADDITIONAL SCOPE OF WORK. ADDITIONAL WORK INCLUDES INTERIOR TI TO LIGHTING. PC STILL T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3674	15041-10000-11179	1547 N CASSIL PL	90028	13	148-5A185 296	5547019014	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Expired	05/09/2017 12:00:00 AM	ADDRESS	34.09938	-118.33393	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING POWER EQUIPMENT.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1325.  SCOPE OF WORK TO BE PERFORMED IN THE FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3675	14041-20001-12003	12650 W SANDHILL LANE Unit 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	33.9774	-118.4142	Fee for expedite only.*****Roof mounted PV system with system size 1.38KW.  Using transformerless inverters.  This part of a series set of submittal.  This PV system to interconnect to common service.  This is project 1 of 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3676	16041-10000-18577	1110 S QUEEN ANNE PL	90019	10	129B185    35	5082005003	RD1.5-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.05376	-118.33037	STANDARD PLAN IS IN USEPV1, NSTALL NEW 6.867KW DC ROOF-MOUNTED SOALR ARRAY ON A SINGLE FAMILY HOUSE.(21) MODULES:SUNPOWER SPR-E20-327-C-AC(21)MICROINVERTERS: THE SAME BRAND	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3677	12041-10000-09004	505 S SAN PEDRO ST 1-108	90013	9	127-5A213 232	5148012019	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Closed	08/01/2012 12:00:00 AM	ADDRESS	34.04392	-118.24444	600 Amp, 120/240 V 3 Ph  temporary service and the related equipment for construction.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3678	16041-20000-23994	4735 N SEPULVEDA BLVD	91403	4	168B145   607	2264001043	C2-1L, R4-2L, [T][Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Closed	09/11/2018 12:00:00 AM	ADDRESS	34.15623	-118.46637	Addition of washer/dryer combo units and microwave to each of (236) apartment dwelling units.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3679	19041-10001-44398	3785 W WILSHIRE BLVD 104A-C	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.06187	-118.30858	Changes to an approved set of plans. Changes to reflect as built. Changes include revising single line diagram to reflect as built.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3680	18041-20000-18790	20756 W SPRUCE CIR (#75)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.29491	-118.58661	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3681	14041-20001-34278	19636 W OXNARD ST	91356	3	177B117   673	2153024027	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.17914	-118.56143	EXPEDITE PER CUSTOMER REQUESTPV1. INSTALL ROOF-MOUNTED SOLAR ARRAY. INTERCONNECTED WITH MAINSERVICE PANEL. SYSTEM SIZE 10 KW. (43) KYOCERA KD255GX-LFB3 MODULES(2) SOLAREDGE  INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3682	10041-30000-05896	10800 W PICO BLVD #225	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.04054	-118.4272	Plan check T-24 Energy (general/emergency) lighting for a retail store at the Westside Pavillion, Suite #225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3683	18041-10000-27127	8811 N SEPULVEDA BLVD	91343	6	195B145   378	2654013007	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Apartment			08/07/2018 12:00:00 AM			PC Info Complete	11/02/2018 12:00:00 AM	ADDRESS	34.23047	-118.46803	New 5-story, 355-unit Apartment building over 1-level subterranean parking. SCOPE INCLUDES THREE 4000A 3 PHASE 4 WIRE SERVICES/DISTRIBUTION BOARDS, NEW PANEL, NEW CIRCUITS.TOTAL AFFECTED AREA Building Permit: 18010-10000-00747	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3684	08041-10003-19063	7230 W FRANKLIN AVE	90046	4	147B181    29	5548001021	R3-1	Central	Hollywood	Hollywood Hills West	YES	1899.03	Electrical	Electrical	Apartment			11/01/2010 12:00:00 AM			PC Approved	11/01/2010 12:00:00 AM	ADDRESS	34.10328	-118.3468	revised single line to show that the feeders to each panelboard is # 4AWG THW 90 DEGREES C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3685	15041-10001-07921	3650 W MARTIN LUTHER KING, JR BLVD Ste 103	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.01118	-118.33649	REVISIONS OF THE SINGLE LINE DIAGRAM; INSTEAD OF  A FEEDER TO SUPPLY PANEL HA FROM WHICH BRANCH CIRCUITS ARE TO SUPPLY THE OTHER PANELS AND XFMR, TWO FEEDERS EACH FROM 200A CIRCUIT BREAKERS TO SUPPLY THE XFMR/PANELS LA& LB; AND TO SUPPLY PANELS HA/L(((((((((Tenant build out of Total Woman Gym within existing tenant space of Baldwin Hills Crenshaw Plaza.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3686	19041-10000-14461	3501 S LA CIENEGA BLVD	90016	10	120B173   365	4205029010	C4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.02395	-118.37251	PLAN CHECK FOR TITLE 24 ONLY IN RESTAURANT SERVICE COUNTER TOTAL EFFECTED AREA 1485 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3687	13041-10000-32316	3912 S TIVOLI AVE	90066	11	108B153    84	4236025036	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	33.99533	-118.44228	PV1, Install 4 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. (1)Transformerless inverter.: Solaredge SE3800A-US. (16) Modules; TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3688	11041-20000-17335	5240 N LANKERSHIM BLVD	91601	4	171B173  1422	2350018***	C2-2, D, CA	South Valley				1253.20	Electrical	Electrical	Public Safety Only			08/16/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.16613	-118.3751	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR  2- STORY, 7-PLEX  THEATERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3689	15041-10000-35735	5301 N TOPANGA CANYON BLVD	91364	3	171B101   482	2169016008	C2-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.16611	-118.60613	Energy plan check for a CHANGE OF USE FROM RETAIL TO ICE  CREAM STORE; Scope includes new lighting, receptacle and  service upgrade to 400-Amps located outside the building with exisitng load from other unit reconnected to the service. Panel for Ice Cream store also upgrade to 200-Amp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3690	18041-20000-03468	16141 W HART ST	91406	6	183B141   370	2224010158	QMR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.19768	-118.48497	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,727 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3691	18041-10000-25636	865 S FIGUEROA ST Lobby	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	11/10/2020 12:00:00 AM	ADDRESS	34.04653	-118.26275	TENANT IMPROVEMENT TO LOBBY OF AN EXISTING OFFICE BUILDING.T-24 ENERGY ONLY. BULDING PERMIT # 18016-10000-21859	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3692	17041-10000-23838	10000 S WESTERN AVE	90047	8	091-5A193  74	6059001033	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	33.94524	-118.30881	PV2, NEW ROOF SOLAR SYSTEM IN A 2 STORY BUILDING USING CENTRAL INVERTERS. (2) SOLAREDGE INVERTERS 20K AND 33.3K, (156) CANADIAN SOLAR MODULES AND (78) OPTIMIZERS. TOTAL SYSTEM 53.3Kac. NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3693	16041-20000-43944	523 W 6TH ST 3rd Floor	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	Plan check for Title 24 only. Project site is the 3rd floor corridor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 486 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3694	19041-20000-26647	990 N HILL ST	90012	1	136-5A215 169	5414007028	C2-2	Central	Central City North	Historic Cultural North		2071.03	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Info Complete	08/01/2019 12:00:00 AM	ADDRESS	34.06691	-118.23727	TI to (E) commercial space for lab.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3695	10041-10001-25038	12930 N BRADLEY AVE	91342	7	222B149   483	2506010007	M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM			PC Info Complete	02/14/2011 12:00:00 AM	ADDRESS	34.30488	-118.45883	Change the approved plan. Addition of 2 air conditioners, Change the the panel schedule and modify the load calc. EPC is for delta2 changes. (((((((((((((((((((((TI IN AN EXISTING COMMERCIAL BUILDING ON THE 1ST FLOOR. PLAN CHECK IS FOR POWER & ENERGY.))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3696	16041-30001-17257	10643 W SUNSET BLVD	90077	5	138B153   103	4362009012	A1-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	34.07571	-118.44485	04/18/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan have been reflected onto the Title 24 Compliance forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing private high school. Project scope is a tenant improvement. Total lighting area = 6,943 sq. ft.Note: Building application has been created under 16016-30000-05732	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3697	19041-10000-27716	11488 W DONA EVITA DR	91604	2	159B169   697	2381009007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.12876	-118.38273	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 39 MODULES (LONGI LR6-72PH 370), 39 OPTIMIZERS (SE P400) AND CENTRAL INVERTER (SE 10000H-US). SYSTEM SIZE IS 14.43KWdc AND 10KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3698	14041-20000-23693	7228 N AMIGO AVE	91335	3	183B121  1185	2118028008	(T)(Q)R3-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			08/29/2014 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.20195	-118.53846	NEW TYPE V-A 22 UNITS 3-STORY W/ TYPE I-A  BASEMENT GARAGE APT BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3699	13041-20000-20612	5815 W SUNSET BLVD STE 103	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	34.09822	-118.31613	Plan check for energy and emergency lighting. Geiger Post. Suite 103. Low rise commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3700	15041-20000-09480	1450 N BIGGY ST B120-A	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.06207	-118.20508	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR A FREEZER FARM IN USC CAMPUS. 1590 SQFT. NEWLY CONNECTED LOAD <400 AMPS. SUITE B120-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3701	16041-20001-21100	17500 W DONMETZ ST	91344	12	210B129   171	2711013020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.27431	-118.51554	Expedite per applicant requestPlan check for PV roof mounted system. System size: 10.5kW with 42 modules and 42 microinverters Enphase.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3702	16041-20001-32997	22129 W MARTINEZ ST	91364	3	171B101   869	2169022010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	ADDRESS	34.1629	-118.60985	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.6 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3703	19041-10000-19612	2500 W 7TH ST	90057	1	133-5A201 278	5141014001	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.0583	-118.28122	Full pc (pwr and energy) for commercial tenant spaces 2 story building. Existing service 800A, 120/240V, 1ph, 3w will existing and new loads. area of scope is 21,000sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3704	14041-20000-35856	10120 N WOODLEY AVE	91343	12	204B141   700	2669007004	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.25451	-118.48468	PV1. Install roof mounted PV system sized 6 KW. Interconnected with main service pannel.(18) Sunpower 327W Modules(1) PVI-6000-TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3705	11041-10000-09040	11757 W CHENAULT ST	90049	11	132B145   386	4401013003	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.05511	-118.46941	FIRE ALARM WITH 1 FIRE ALARM PANEL AND 127 DEVICES.  REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3706	16041-10001-04445	3033 E 11TH ST	90023	14	118-5A223  10	5170024016	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	34.02059	-118.21337	03/11/16Changes to an approved set of plans. Changes include lighting fixtures, office power floor plan layout showing individual occupancy controlled receptacles, panel schedule circuits, and lighting circuit wiring.  (((((TI to (E) commercial office space in (E) commercial lowrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3707	14041-10000-07243	11985 W BLUFF CREEK DR	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	33.98221	-118.40251	METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35598.BDLG PERMIT: 13110-10000-04243	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3708	18041-10001-24003	1409 N SPAULDING AVE	90046	4	147B177  1221	5551023002	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM			PC Approved	08/15/2018 12:00:00 AM	ADDRESS	34.09647	-118.35722	SUPPL. PLAN CHECK FOR REDUCING NUMBER OF AC MODULES FROM 31 TO 26. PC FOR ROOF MOUNETED PV ON SFD.  SYSTEM SIZE 8.347 KWAC /9.36 KWDCSCOPE INCLUDE 26 AC MODULES WITH NEW LOAD CENTER. PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER 18041-10000-24003	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3709	17041-20000-12407	823 S HUDSON AVE	90005	4	132B185   173	5090005003	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.0601	-118.33385	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3710	15041-20000-09457	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.2312	-118.36756	PC FOR SHELL OUT FOR FUTURE STARBUCKS. INSTALLING BUS EXTENSION FOR FUTURE RETAIL. PC FOR POWER and ENERGY. INSTALL RESTROOM LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3711	10041-10000-11911	219 W 7TH ST	90014	14	127-5A211  40	5144002025	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	34.04504	-118.25277	"CHANGE OF USE FROM RETAIL TO TAKE -OUT RESTAURANT  (MEDITERRANE GRILL ) .PLAN CHK IS FOR TITLE 24 ""COMPLY WITH DEPARTMENT ORDER effective date07/06/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3712	16041-10000-45530	1230 S OLIVE ST	90015	14	126A207   209	5139024016	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.03857	-118.26278	FULL PC FOR POWER AND ENERGY. TI FOR A NEW CORE AND SHELL RESTAURANT. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. FIRST TIME TENANT AND A-OCCUPANT LOAD > 100. TOTAL AFFECTED AREA IS 5745 SQ. FT. B#16016-10000-31017ALL EXISTING ELECTRICAL LOAD CALCULATIONS AND FAULT CURRENT CALCULATIONS WERE TAKEN FROM AS-BUILT DRAWING PERMIT #14041-20000-28043	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3713	19041-10000-37864	1149 S HILL ST 10TH FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.03926	-118.26099	Energy plan check for a corridor T.I. Scope includes new lighting and equipment with a total lighting area of 127-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3714	11041-10000-17325	6401 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	05/08/2012 12:00:00 AM	ADDRESS	34.18624	-118.59778	NEW FIRE ALARM SYSTEM FOR AN EXISTING BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3715	16041-10000-20799	1654 W 54TH ST	90062	8	108B193   532	5003019013	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	33.99314	-118.30653	Addition of 05.3 kw dc roof-mounted solar PV system to the existing system, (20) modules: kyocera  ku2656zpa(1) inverter: abb pvi-3.6-outd-s-us-z-a	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3716	14041-20003-05382	23440 W COMMUNITY ST	91304	12	192B093   305	2005016025	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.22104	-118.63783	Wiring and layout of modules modified from approved set.  (((PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING SOLAR EDGE SYSTEM WITH POWER OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3717	14041-10001-05668	2063 N ROSCOMARE ROAD	90077	5	150B145   138	4377013016	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.10767	-118.46362	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. {{PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(8) MODULES: YINGLI YL250PL-29b(1) SOLAREDGE SE3000-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3718	14041-20000-09315	6130 N LANKERSHIM BLVD	91606	2	177B169   413	2338005008	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.18212	-118.38481	BEAUTY SALON. NEW LIGHITNG AND PARTITIONS. PC FOR T24 ENERGY. PERMIT ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3719	18041-10000-17541	2141 W JEFFERSON BLVD	90018	10	120B189   653	5052007009	C2-1VL-O-HPOZ-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.02569	-118.31893	PC  FOR NEW FA IN SINGLE STORY COMM. BUILDING. SCOPE INCLUDES NEW FACP WITH VOICE EVAC AND INCLUDES 27 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3720	16041-20000-15653	22361 W WELBY WAY	91303	3	180B101   167	2139009032	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.1922	-118.6136	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (34) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3721	16041-20000-04526	16788 W OAK VIEW DR	91436	5	168B133   592	2289022020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.15595	-118.49903	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.9 KW.   TWO SEPARTE MODULE TYPES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3722	14041-10000-04673	14476 W VALLEY VISTA BLVD	91403	4	165A151   158	2276038018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	PIN	34.14652301	-118.44956559	PV1, INSTALL 7.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(31) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3723	12041-10000-29447	716 N FLINT AVE	90744	15	030B209   252	7424022012	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	33.77977	-118.24919	NEW FIRE ALARM SYSTEM 28 DEVICE AND 1 PANEL. TWO STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3724	19041-20000-10637	3410 S GRANVILLE AVE	90066	11	117B153   825	4249010003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.01529	-118.43383	Plan check for Energy stroage system in to existing PV. Energy stroage syste size: 13.5kWh, Tesla Power Wall 2.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3725	14041-10000-32348	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Expired	08/17/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	Plan check for power. Addition of (7) lighting fixtures and 1 Rec outlet on new clay filter vessel  using esxisting electric circuts. Class 1 div 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3726	14041-10000-10981	6007 S ST ANDREWS PL	90047	8	105B193   569	6001018009	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	33.98484	-118.3116	plan check for power. CORE/SHELL FOR (E) 2 STORY BLDG. THIS PERMIT COVERS THE COSTS OF BOTH 14041-10000-10981 AND 14041-10001-10981.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3727	15041-10000-12293	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Issued	09/10/2015 12:00:00 AM	ADDRESS	34.04538	-118.26335	new fire alarm system 177 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3728	12041-20000-26762	11350 W SHELDON ST	91352	7	201B173   117	2538023006	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM			Corrections Issued	12/12/2012 12:00:00 AM	ADDRESS	34.25051	-118.37823	Ground mounted Photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3729	18041-20000-16531	7600 N BALBOA BLVD #203	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Plan check for first time tenant retail space new lighting and receptacle. Total area: 862 sq ft.B#18016-10000-13841	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3730	16041-20000-40166	6701 N RUDNICK AVE	91303	3	180B101   217	2139009022	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.19186	-118.61259	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (3) inverters, (51) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3731	12041-20000-25263	12556 W CANTARA ST	91605	6	192B161   361	2308007008	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.21974	-118.4074	New 4kw rooftop mounted PV system for an existing sfr.  System uses Enphase micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3732	19041-10000-31179	801 S GRAND AVE 1ST FLR	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Issued	09/10/2019 12:00:00 AM	ADDRESS	34.04581	-118.25842	TI IN THE CONF. ROOM AN EXISTING COMMERCIAL AREA (CAPITAL ONE) ON THE FIRST FLOOR OF A HIGH RISE BULDING.  INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 19016-10000-23665	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3733	17041-20000-23171	14040 N CAROL LANE	91342	7	228B141   523	2603026021	(Q)R1-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.31957	-118.48276	PV1.  Install 3.92 kW roof mounted grid tied PV system.  (14) modules with Enphase M250 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3734	10041-20000-21444	315 W 5TH ST	90013	14	129A211    56	5149026001	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM			PC Info Complete	10/27/2010 12:00:00 AM	ADDRESS	34.04847	-118.25108	ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3735	17041-20000-26129	19118 W BALLINGER ST	91324	12	198B121    49	2762010004	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.24306	-118.5505	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3736	13041-20000-15053	1340 E 6TH ST flr 6	90021	14	126A217   152	5164011001	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/16/2013 12:00:00 AM	ADDRESS	34.03813	-118.23423	T24 FOR HIGHRISE BUILDING. SCOPE OF WORK ON THE 6TH FLOOR. LOAD LESS THAN 400A PER APPLICANT. TOTAL SQRFT 40,832.  Permit fees are under Inspection for 32, 60 amp sub panels on a 400 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3737	19041-10000-11706	3360 S BEETHOVEN ST	90066	11	114B149   547	4244006032	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.00857	-118.44786	[ePlan] $0 fee due to AB1414.  New rooftop 7.6 kW PV1 and (4) ESS. Installation consist of (1) 7.6 kW AC inverter, (26) modules, (4) ESS @ 54kWh total, (1) 200A subpanel, and (1) 125A subanel. System connect to (E) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3738	14041-20001-22199	15217 W KNAPP ST	91343	7	198B145   261	2656024014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			PC Approved	09/04/2014 12:00:00 AM	ADDRESS	34.2382	-118.46374	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WOTH MSP.(28) TRINA SOLAR TSM-255 MODULES(1) SOLAREDGE  SE6000(28) SOLAREDGE OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3739	10041-10001-23713	17836 W CATHEDRAL PL	91316	5	165B129   207	2184029008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.14922	-118.52188	REVISIONS TO PERMITTED SET OF PLANS))))))))))))))NEW 16.38 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3740	15041-20000-02795	13335 W MAXELLA AVE	90292	11	108B153  1268	4230006027	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	33.98802	-118.43906	TI TO OFFICE SPACE. PC FOR POWER AND ENERGY. 2 FLOORS. GREATER THAN 400A LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3741	14041-20001-06646	4553 N WILLIS AVE 1-20	91403	4	168A149   178	2264017035	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.15368	-118.45537	Fee for expedite only.*****Roof mounted PV system with system size of 33KWdc (System Size need to be verified) .*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3742	10041-20000-06248	2414 N DALY ST 2414-2424	90031	1	138A221    26	5204012900	PF-1-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/10/2010 12:00:00 AM	ADDRESS	34.0742	-118.21547	REPLACE FIRE DAMAGED SERVICE AND EXTENDING FEEDERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3743	17041-20000-00336	11440 W SHELDON ST	91352	6	201B169   240	2538022028	(Q)M2-1-CUGU, [T][Q]M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.24887	-118.3804	ti to an existing commercial building.  adding new lighting new controls to existing panels.  total square footage 1044.  plan check for enery only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3744	14041-10000-09156	940 S MAGNOLIA AVE 1-23	90006	1	132A201   327	5076005025	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Apartment			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.05439	-118.28643	Fire alarm for a commercial building. replacing an old fire alarm panel with new one.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3745	15041-10000-20217	6923 S KITTYHAWK AVE	90045	11	102B173   225	4103010023	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			07/06/2015 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	33.97495	-118.37278	Full plan check for a 4-story, 25-unit apartment building . Total area for T-24 is 19438-SQ feet.Portion of fee is paid under early permit submital and original plan checker is M.Z .  this application is a supplemental to Reference application #: 14041-10000-15550	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3746	13041-10001-24717	14722 W MAGNOLIA BLVD UNIT 4	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3747	17041-10001-41036	5516 N HERMITAGE AVE	91607	2	174B165   856	2347012012	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.1708	-118.40019	EXPEDITED FEES PER APPLICANT. PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND OPTIMIZERES. (60) MODULES AND (1) 11.4KW INVERTER. TOTAL SYSTEM SIZE IS 11.4KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3748	15041-20000-00775	8877 N ZEILER AVE	91331	6	195B153   582	2640023016	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.23111	-118.43348	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNECTED WITH MSP.(16) HYUNDAI HEAVY INDUSTRIES HIS M250 MODULES(16) ENPHASE M215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3749	14041-20000-27991	15746 W ADDISON ST	91436	5	171B141   475	2261004003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.16155	-118.47645	PV1.  Install 5.395 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.  Mixing of (2) distinct module types on single string.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3750	15041-20000-23069	888 W 6TH ST 12th floor	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.05062	-118.25846	Title 24 plan check only.  Total area = 5,088 sq. ft.  T.I. to existing commercial highrise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3751	15041-20001-00582	11852 1/2 N BALBOA BLVD	91344	12	216B133   474	2610002048	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	34.28546	-118.50127	05-29-15 Change to approve set of plan. Changes apply to delta 1 only. [[[[[MASSAGE PARLOR. NON MEDICAL TO BE VERIFIED BY INSPECTOR. PC FOR T24 ENERGY ONLY. NEW LIGHTING. LOW LOADS.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3752	14041-20000-01398	7734 N SALE AVE	91304	12	189B097  1032	2013017004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.21118	-118.6184	New rooftop PV system using two UNGROUNDED inverters for an existing single family dwelling.  Service Panel Upgrade is not a part of this permit and is to be pulled SEPARATELY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3753	17041-20001-39157	8900 N DE SOTO AVE B-102	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.23162	-118.58832	11/1/2017changes to an approved set of plans.  changes noted delta 1.  changes include new secondary fused disconnect to existing transformers and provide main lugs only on secondary panels.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3754	16041-20000-18456	420 E MONTECITO DR	90031	1	147A225   179	5303005033	[Q]R1-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.09504	-118.20137	Plan check for PV roof mounted system. System size: 3.8kW with 8 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3755	15041-20000-02765	12484 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	EXPEDITE PER CUSTOMER EQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3756	14041-10000-14927	9723 N COLUMBUS AVE	91343	7	201B145   420	2656005016	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.24727	-118.46543	Install roof mounted solar array.2 Inverters with output = 4.2 kW each	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3757	17041-10000-09733	351 S FULLER AVE LOT D	90036	4	135B181   159	5509005008	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.06852	-118.35108	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 38650 SQ. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3758	17041-20000-41161	4874 N TOPANGA CANYON BLVD	91364	3	168B101   556	2171016076	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.15637	-118.60558	Plan check for energy only. TI/Change of use from retail to restaurant (ice cream parlor). New lighting, 718sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3759	16041-20001-22239	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM			PC Approved	08/02/2016 12:00:00 AM	ADDRESS	34.06488	-118.47066	08/01/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to differentiate between the work being done for Phase I and Phase II.*****Previous Work Description*****Phases I and II of North Wing Renovation project of (E) school.  Temporary distribution for future construction and temporary classrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3760	19041-10000-34261	917 S BERENDO ST 1-10	90006	10	132B197   939	5094024006	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	11/19/2020 12:00:00 AM		Permit Finaled	05/08/2023 12:00:00 AM	ADDRESS	34.05525	-118.29438	FULL PLAN CHECK FOR A NEW 10 UNIT, 4 STORY APARTMENT COMPLEX. SCOPE INCLUDES NEW 600A SERVICE. TOTAL AFFECTED AREA 11949 SQ.FTFA Variance has been submittedB#18010-10000-00075	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3761	13041-20000-19306	13671 N SHABLOW AVE	91342	7	228B161   534	2580009009	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Expired	07/09/2018 12:00:00 AM	ADDRESS	34.32082	-118.40982	"New 5.145kw Roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED and uses ""Power Optimizers""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3762	17041-10000-38199	20121 W VENTURA BLVD	91364	3	174B113   468	2166033020	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.17079	-118.57203	PC for replacement of existing fixtures with LED fixtures T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3763	13041-10000-00938	6455 N TOPANGA CANYON BLVD	91303	3	180B101   662	2139002017	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM			PC Approved	01/16/2013 12:00:00 AM	ADDRESS	34.18805	-118.60623	"3 CONNECTED PROPERTIES BEING RENOVATED FOR TI.  T24 ONLY.  PROPERTY ADDRESSES 6455, 6457, AND 6459 N. TOPANGA CANYON.""COMPLY WITH DEPARTMENT ORDER effective date 11/12/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3764	19041-20000-36156	6701 S CENTER DR WEST Ste 750	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	TI to commercial office tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3765	16041-20000-37845	50 W BEVERLY PARK WAY	90210	4	153B161    18	4386014030	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.11925	-118.41848	PLANCHECK FOR POWER. TEMPORARY POWER. 600 AMPS 120/208 V	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3766	17041-10000-08669	3350 W WILSHIRE BLVD	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.0615	-118.29586	Intallation of a new fire alarm sytem to a change of use from office to appartment. 3 FA panels, 471 FA devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3767	19041-10000-42760	6320 N TOPANGA CANYON BLVD G-1630	91367	3	180B105    60	2146029022	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM			PC Info Complete	10/30/2019 12:00:00 AM	ADDRESS	34.18578	-118.60536	ENERGY PLAN CHECK FOR A TI. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 270SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3768	13041-10001-34144	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM			PC Approved	02/27/2015 12:00:00 AM	ADDRESS	34.06188	-118.30486	Changes to an approved set of plans. Changes include the change of copper feeders to aluminum feeders. A copy of the original set of plans will be brought at a later date, as approved for submittal by M.Z. 1/30/2015(((Construction of a mixed-use structure with one basement parking level, three parking levels at or above grade, and a level 4 play deck and central plant, associated site work and new play yards for adjacent buildings not a part of this permit application.  Plan check for power and energy, 181,543 sq ft.  New 1600 A distribution board, 45 kVA XFMR and associated distribution equipment.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3769	13041-10000-07840	3812 S MOORE ST	90066	11	111B153   774	4236016015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.00	Electrical	Electrical	Public Safety Only			03/27/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	33.99985	-118.43997	Central station monitoring system for the sprinkler system in a 5 units apartment building; has a FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3770	11041-10000-05104	1603 W 25TH ST	90732	15	009B189   138	7563016014	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	33.72304	-118.31334	NEW ONE-STORY BANK BLDG, NEW SERVICE AND METER.  FULL PLAN CHECK.  VERIFY SQ. FT. OF T-24 FOR FEES (OUTDOOR LIGHTING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3771	13041-10000-15487	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Info Complete	08/29/2013 12:00:00 AM	ADDRESS	34.06725	-118.41704	Plan check for new medium voltage 4.6KV service, site medium voltage unit substation distribution, and equipment for existing country club. Site located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3772	14041-10000-26177	4180 W WILSHIRE BLVD	90010	4	132B189    59	5092001022	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			09/23/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.06148	-118.31872	NEW 29 UNIT 5 STORY APARTMENT BUILDING. METHANE BUFFER ZONE. BUILDING PERMIT#: 13010-10000-04205	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3773	18041-20000-22399	515 S FIGUEROA ST 17th FLR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	Ti for corridoors and restyrooms  17th floor of a high rise bldg.Title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3774	18041-20000-36929	1827 S MESA ST LOT 7	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.72732	-118.28602	Plan check for PV roof mounted system, system size: 3.02KW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3775	18041-10000-01289	540 N MOUNT HOLYOKE AVE	90272	11	126B125   781	4412017007	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Issued	02/21/2018 12:00:00 AM	ADDRESS	34.03926	-118.53004	PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL (200A).NEW MAIN SERVICE PANEL @ 200A, NOT PART OF PERMIT FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3776	18041-10000-07506	20929 W VENTURA BLVD	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	TENAT IMPROVEMENT IN AN EXISTING BAKERYPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3777	11041-10000-04974	2830 S CENTRAL AVE	90011	9	117A209   110	5119014032	[Q]M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.01575	-118.25594	FIRE ALARM.  FOR A PRIVATE SCHOOL.  1 PANEL,  111 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3778	19041-10000-51558	240 N CATALINA ST	90004	13	138B197   434	5518025002	R3-1	Central	Wilshire	Wilshire Center-Koreatown		2112.02	Electrical	Electrical	Apartment			12/13/2019 12:00:00 AM	09/27/2022 12:00:00 AM		Permit Finaled	10/04/2022 12:00:00 AM	ADDRESS	34.07574	-118.29528	FULL POWER & ENERGY PC FOR A NEW 600AMP 120/240V 1PHASE 3WIRE SERVICE. TOTAL AFFECTED AREA 6010sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3779	17041-10000-43032	7262 N CAMELLIA AVE	91605	2	186B169   903	2316025014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.20297	-118.38219	PC FOR ROOF MOUNTED PV ON SFD. TOTAL SYSTEM SIZE 6.3KWDC/ 5.0 KWACSCOPE INCLUDES 19 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3780	11041-10000-16201	13919 W HUBBARD ST	91342	7	222B153   691	2509011027	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.30243	-118.43619	T.I.  Exisitng 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3781	17041-10000-04262	1000 W TEMPLE ST	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Info Complete	04/12/2017 12:00:00 AM	ADDRESS	34.06171	-118.25046	VoidPC FOR METHANE MITIGATION SYSTEM. GAS DETECTION PROVIDED. TOTAL OF 121 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3782	18041-20001-31574	14630 W SATICOY ST	91405	6	186B149   219	2218003032	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.20831	-118.45189	Expedited plan check fee.PV2.  Install 28.275 kW roof mounted grid tied PV system.  (87) modules with (2) 11.4 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3783	15041-10000-30333	13069 W VICTORY BLVD	91606	2	180B161   789	2326017002	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Expired	11/23/2017 12:00:00 AM	PIN	34.18883938	-118.41818567	PC FOR ENERGY ONLY,  MAINTENANCE AND REPLACEMENT OF LAMPS ON EXISTING FIXTURES TO AN LA FITNESS. TOTAL SQ. FT. 6821. FEES for the lighting alterations PAID UNDER EXPRESS PERMIT 15041-10000-24097.;PERMIT FOR POWER IS OBTAINED UNDER THIS ALTERATION  APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3784	18041-10000-06186	748 N AMALFI DR	90272	11	126B133   118	4408015006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Expired	08/28/2023 12:00:00 AM	ADDRESS	34.04237	-118.51108	PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL 5.8KVA) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL(200A).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3785	15041-10000-05809	12976 W GLAMIS ST	91331	7	204B161   152	2623009018	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.25755	-118.41551	PV1 ROOF MOUNTED STANDARD PLAN. TOTAL SYSTEM SIZE 3KWAC. 8 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3786	17041-20000-46283	13276 W SUNBURST ST	91331	7	201B157   621	2622014014	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.24583	-118.42236	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. (E) solar system on site.Derating main breaker from 200A to 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3787	19041-20000-01951	12217 W EMELITA ST	91607	2	174B165   118	2340009013	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Issued	01/29/2019 12:00:00 AM	ADDRESS	34.1764	-118.39938	PV1.  Install 14.4 kW DC / 12.2 kW AC roof mounted grid tied PV system. (40) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3788	15041-20000-06761	11507 W OXNARD ST Unit 2	91606	2	177B169   797	2338004012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.1796	-118.38271	Plan check for Title 24 only. Project is the installation of new lighting for a pharmacy. Total lighting area = 806 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3789	17041-10000-01942	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.18684	-118.3977	FULL PC FOR POWER AND ENERGY FOR AN EXISTING  CORE AND SHELL COMMERCIAL BUILDING. SCOPE INCLUDES ADDING A NEW 3000A 277/480 3 PHASE 4WIRE SERVICE/DISTRIBUTION BOARD,  NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS FOR AN EXISTING MULTI-TENANT SPACE. TOTAL AFFECTED AREA IS 470 SQ. FT. B#17016-40000-01248	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3790	14041-10000-22160	5647 W TRYON ROAD	90068	4	151-5A193 263	5587021026	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			Reviewed by Supervisor	09/09/2014 12:00:00 AM	ADDRESS	34.10763	-118.31109	PV1, INSTALL 7.14 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(28) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3791	16041-10001-14302	3600 W WILSHIRE BLVD 100	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.06156	-118.30335	02/06/16Changes to an approved set of plans. All changes are clouded under Delta 1. Revising single line diagram to reflect what is on the field. Note: permit is paid under PCIS#16041-10001-14302	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3792	16041-10000-28711	1338 W 7TH ST	90017	1	130-5A205 139	5143012033	C2-2	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM			PC Info Complete	10/07/2016 12:00:00 AM	ADDRESS	34.05243	-118.26849	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM  EXISTING RETAIL TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1904 SQ. FT. B#14016-10000-23369	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3793	13041-20000-34589	3512 N COPELAND PL	90032	14	142-5A237  92	5219022021	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.08583	-118.16536	New rooftop  PV system.  SYstem is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3794	11041-20000-04517	6301 N OWENSMOUTH AVE 9 th floor-FLOORS	91367	3	177B105   123	2146029016	WC	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.18467	-118.60176	remodel 9th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3795	13041-10000-05963	642 W 95TH ST	90044	8	093A201   106	6039009006	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	33.94999	-118.28614	PV1 ROOF MOUNTED SOLAR INSTALLATION ON SINGLE STORY BUILDING USING MICROINVETER STANDARD PLAN. SYSTEM SIZE IS 2.16 KW. [MODULES: CENTRO SOLAR # E250 |||| INVERTER ENPHASE # M215]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3796	18041-20000-11841	10006 N COZYCROFT AVE	91311	12	204B109   477	2741024010	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.2519	-118.58183	PV1.  Install 8.265 kW DC roof mounted grid tied PV system and 9.8 kWh energy storage system. (29) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3797	18041-10000-41057	4801 S MAIN ST	90037	9	111A203   116	5110018035	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.99901	-118.27415	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3798	14041-10000-21392	14402 W CALIFA ST #3	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3799	17041-10000-06711	4020 S ROXTON AVE	90008	10	114B189   247	5034015019	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.01136	-118.32152	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR) TOTAL AREA 48725 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3800	16041-10000-02322	12690 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	33.97692	-118.41538	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) MODULES(1) 3000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3801	14041-20001-00499	7625 N KELVIN AVE	91306	3	186B109   160	2108033009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.20902	-118.58643	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3802	15041-10000-05514	3650 W MARTIN LUTHER KING, JR BLVD UNIT 222	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.01118	-118.33649	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTINGNEW CONTROLS AND NEW PANELS. NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 3442	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3803	16041-10001-44713	216 N LARCHMONT BLVD #216A	90004	4	138B189   584	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.07531	-118.32344	02/28/2017 Changes to an approved set of plans. Changes include lighting fixture change out and reclaculate Title 24. Changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3804	12041-10000-16646	13436 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.15935	-118.42611	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #9	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3805	13041-10000-02569	4747 N COLLIS AVE	90032	14	148-5A233  65	5301025022	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	2013.02	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2013 12:00:00 AM			Verifications in Progress	03/01/2013 12:00:00 AM	ADDRESS	34.10103	-118.17854	sumittal 2 for additional panel added.PV1 FOR 2-story SINGLE FAMILY DWELLING.  5.46 KW DC. 21 MODULES {MODULE: AUO GREENTRIPLEX PM260M00}  MICROINVERTERS {ENPHASE M215-60-2LL-S22/S23 MICROINVERTER 215W}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3806	16041-20000-03638	14068 W VANOWEN ST	91405	2	180B153    66	2238006053	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM			PC Approved	02/01/2016 12:00:00 AM	ADDRESS	34.19379	-118.43955	Plan check for energy only. Add (4) new LEDs in existing barbershop. 824sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3807	14041-20001-05228	12805 W NORTH SEAGLASS CIR	90094	11	102B161  1224	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	33.97505	-118.41793	*** EXPEDITE FEE ONLY***   PV1 TRANSFORMERLESS SYSTEM.  TOTAL SYSTEM SIZE 2.25 KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3808	15041-20000-16305	936 S OLIVE ST UNIT 254	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #12 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3809	19041-10000-38603	11797 W PICO BLVD	90064	11	123B149   785	4260029017	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	34.03084	-118.44777	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3810	19041-10000-50040	1570 W YOSEMITE DR	90041	14	160-5A227 365	5689028035	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	Apartment			12/05/2019 12:00:00 AM			PC Approved	03/02/2020 12:00:00 AM	PIN	34.13235903	-118.20049855	Complete plan check for remodel of apartment units. Service size 600A. 120/240V, Single-phase, 3-wire.Scope of work 13200SF.*******REMODEL 8 UNITS TO AN EXISTING 2 STORY 8 UNIT APARTMENT BUILDING*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3811	16041-10000-19570	12011 N BRADFORD PL	91344	12	216B133   250	2606022012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.28934	-118.50407	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(39)MODULES-CANADIAN SOLAR CSP6P-265P(39)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE TECH 10000A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3812	14041-10001-10318	812 N CORONADO ST	90026	13	139-5A205 181	5402021011	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1957.10	Electrical	Electrical	Apartment			04/18/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.07696	-118.27038	(((EXPEDITE FEES)))PV2 ROOFTOP TRANSFORMERLESS SYSTEM USING SOLAR EDGE OPTIMIZERS FOR TRIPLEX. TOTAL SYSTEM SIZE IS 3.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3813	16041-10000-44859	1999 S AVENUE OF THE STARS 37th flr	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Issued	01/12/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 37TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SPACES. TOTAL AFFECTED AREA IS 6146 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3814	10041-10000-19780	6150 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	(Q)C4-1L, C4-1, C4-1L, P-1, P-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.00	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	05/18/2011 12:00:00 AM	ADDRESS	34.18223	-118.39491	PARTIAL REMODEL TO THE INTERIOR OF THE MACY'S STORE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3815	10041-10000-21617	2500 S NAVY WAY PIER 400	90731	15	021B209   245	7440022909	M3	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	03/22/2011 12:00:00 AM	ADDRESS	33.73363	-118.2408	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3816	14041-10001-15699	6101 W CENTURY BLVD	90045	11	090B169     4	4124030036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM			PC Info Complete	03/10/2015 12:00:00 AM	ADDRESS	33.9457	-118.39149	((3/6/2015))CHANGES TO AN APPROVED SET OF PLANS.  ADDING LIGHTING TO THE 15TH FLOOR, REVISED ENERGY CALCULATIONS.  FIRST FLOOR LOBBY <50% OF THE EXISTING LIGHTING ALTERED EXEMPT FROM ENERGY CALS.PLANCHECK FOR T24 ENERGY. SHERATON- LAX.  TENANT IMPROVEMENT FOR LOBBIES. 32018 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3817	15041-10004-33053	9254 N WINNETKA AVE BLDG C	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Closed	02/04/2021 12:00:00 AM	ADDRESS	34.23884	-118.57087	DELTA 25. 26, 27, & 31 CHANGES TO APPROVED PLANS. REPLACING ONE AIR CONDITIONER TO TWO AC's IN EACH UNIT, ADDING NEW CIRCUITS TO UNIT PANELS, CHANGES TO LIGHTNG IN THE COMMON AREAS AND CHANGES TO FEEDERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3818	14041-20002-33210	6926 N RUBIO AVE	91406	6	183B137   325	2225007020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.1964	-118.49556	1/9/2015 - Modification to approved set. Change module layout on roof only. Delta 1 revisions.[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. Using 300W power optimizers.29 235W/250W (mixed) pv modules across two strings (14+15).]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3819	16041-10000-36043	1350 N BROAD AVE	90744	15	036B205  1264	7422008041	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Expired	10/28/2023 12:00:00 AM	ADDRESS	33.79016	-118.2614	NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER. (12) PANELS AND (1) 5KW INVERTER. TOTAL SIZE IS 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3820	13041-10000-13726	10009 N WHITAKER AVE	91343	12	204B133   651	2685004012	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.25237	-118.49922	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A DWELLING. SYSTEM SIZE IS 9.065 KW USING 37 MODULES IN 4 STRINGS. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTERS: SOLAREDGE # SE3800A-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3821	09041-10001-20829	3677 S CRENSHAW BLVD	90016	10	117B185    73	5046023007	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM			PC Approved	01/05/2010 12:00:00 AM	ADDRESS	34.0206	-118.33534	This revision to previously approved plan. The change was showing panel B separetly instead of being subpanel to panel A. The load  on panel A is less than the one previously approved.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3822	12041-10002-09991	8500 W BURTON WAY # 100	90048	5	138B173  1128	4334016087	(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	ADDRESS	34.07095	-118.37677	"DELTA 2 CHANGES TO THE APPROVED PLANS.  THE ""LOCKER ROOM"" AND THE ""BREAK ROOM"" WAS MOVED FROM ONE SIDE OF TRADER JOES TO THE OTHER SIDE. LOW RISE BUILDING. THE NUMBER OF LIGHTS ARE THE SAME. NO NEW CIRUITS OR PANELS ADDED. NO OTHER CHANGES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3823	17041-10000-05843	14453 W OXNARD ST	91401	6	177A151    91	2240007901	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			Verifications in Progress	09/19/2017 12:00:00 AM	ADDRESS	34.17957	-118.4481	installing commercial PV system on roof top of two sepearte buildings with same address. System is being added to an existing system. Total size: 153.3 KW, 480 modueles for wherehouse and 90 solar modules for the garage roof top connected to strings per inverter. 570 solar modules total. New switch gear rated at 600 Amps dedicated for PV only. NOTE** APPLICANT MAY REQUIRE 2 SEPARATE PLAN CHECKS SINCE SCOPE IS CURRENTLY UNDER 2 DIFFERENT BUILDINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3824	16041-20001-33525	23335 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.1573	-118.63409	Plan check for Title 24 only. Project site is an existing commercial shopping center. Project scope is building lighting and parking lot lighting. Total lighting area = 112,827 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3825	13041-20000-06193	4680 S LINCOLN BLVD	90292	11	105B153   147	4224014021	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Issued	03/08/2013 12:00:00 AM	ADDRESS	33.98105	-118.43929	remodel mcdonald energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3826	19041-20001-21115	2727 S CLUB DR	90064	5	126B161    85	4308003006	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.04209	-118.40577	Expedite per applicant per applicant request Plan check for PV roof mounted system, PV system size: 19.14KW DC, 16.27KW AC with 58 PV Modules and 2 inverters(10KW) connected to existing 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3827	17041-20002-29152	7243 N CEDAR ROAD	91405	2	186B153   937	2217032106	(T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.20259	-118.44077	[[9/22/17 Changes to approved set. delta 1 changes. plancheck only. changing modules to Solar city #SC325 and providing disconnect between the energy storage device and panelboard.]]Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 3 kWac and consists of (1) inverter, (6) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3828	12041-20000-08869	426 S SPRING ST	90013	9	129A211    78	5149023007	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.04812	-118.24872	Outdoor lighting for a park. 13602 outdoor sqft. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3829	13041-20000-18996	932 S HILL ST	90015	14	127-5A209 243	5139003014	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.04216	-118.25766	New 1600 amp service, new panels, lighting, and loads.  Mixed use, retail/housing.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3830	16041-10000-31893	555 W 5TH ST 3375	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR TITLE 24.33RD FLOOR OFFICE SPACE IN A HIGH RISE. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES.TOTAL AREA OF 4065 SQ.FT.************************************************************************************TI REMODEL NON BEARING INTERIOR PARTITIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3831	11041-10002-00376	426 S HILL ST	90013	14	129A211    18	5149025008	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.04946	-118.25094	CHANGES MADE TO PREVIOUSLY APPROVED SET OF PLANS,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3832	17041-10000-32175	118 S AVENUE 50	90042	1	150A225   277	5467014015	R3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.20	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.1042	-118.20184	PLAN CHECK FOR FIRE ALARM SYSTEM - SYSTEM CONSIST OF 2 FIRE ALARM PANELS AND 13 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3833	12041-10000-21154	3430 S VERMONT AVE	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	03/18/2013 12:00:00 AM	ADDRESS	34.02479	-118.29132	Installation of  MV unit substation and associated  480V power distribution equipment to provide power to 13 ea California State certified trailers on the USC campus. These trailers are for a temporary research facility. Each trailer is rated 120/208V, 3Ph, 125Amp to be verified in the field.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3834	18041-20000-24310	5561 E HUNTINGTON DR NORTH	90032	14	147A239   278	5309024003	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.09497	-118.1589	Plan check for new Fire alarm system, for Daycare, Fire alarm devices: 73 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3835	12041-20000-29806	1134 N CHARM ACRES PL	90272	11	129B125   394	4423001027	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.04966	-118.52563	PV-1. Plan check for enphase micro inverters. 400A main panel. 6.38kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3836	18041-30000-17326	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Full plan check for a change of use area located in LAX terminal-2 level 1, 2 and 3. Scope includes new lighting and equipment.Building referrence application #: 18014-10002-00667	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3837	16041-20000-38514	3857 N BEVERLY RIDGE DR	91423	4	162B149   305	2274017003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.14112	-118.44635	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP.Derating main breaker to 175A. 8.2kW ungrounded system. (36) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3838	14041-10000-29953	11115 N LAUREL CANYON BLVD	91340	7	210B149   706	2613025053	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.2721	-118.44668	Plan check for a PV2 system. System size is 446 kW. System consists of (2,000) 250W DC modules, and (14) inverters.Permit fee waived due to Senate Bill SB-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3839	17041-20001-33491	23950 W SCHOENBORN ST	91304	12	192B089   145	2017037013	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.22089	-118.64882	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.6.6kW ungrounded system. Interconnecting with 400A MSP.(26) 305W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3840	16041-20000-02114	5725 S ST ANDREWS PL	90062	8	108B193  1136	5005023020	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Expired	03/05/2018 12:00:00 AM	ADDRESS	33.99021	-118.31148	Plan check for PV roof monted system. System size: 3.8kW with 9 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3841	17041-20000-06994	10244 N CANDLEBERRY LANE	91324	12	204B121   168	2729027037	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.25671	-118.55074	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (44) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3842	18041-10000-43494	15071 W KESWICK ST	91405	6	189B145   621	2209037035	M2-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.21045	-118.46175	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3843	19041-10000-53654	5263 W ADAMS BLVD	90016	10	123B177   910	5043003050	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	10/29/2020 12:00:00 AM		Permit Finaled	06/02/2021 12:00:00 AM	ADDRESS	34.03266	-118.35751	T.I PC FOR T-24 ENERGY ONLY. AFFECTED AREA 1922 sqft. SCOPE OF WORK INSLUDES INSTALLATION OF NEW PANELNOARDS & EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3844	10041-10001-15129	20801 W RINALDI ST	91311	12	210B109   548	2706007024		North Valley			YES	1131.00	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.27025	-118.58647	revisions to permitted set of plans ;changes are clouded and identified as Delta 3 changesNew gymnasium building.  New service, switchboard, panels, and branch circuits.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3845	19041-20000-37207	12323 W HESBY ST	91607	2	171B165   890	2356021014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.16238	-118.40171	Plan check for PV roof mounted system and Energy Storage System, PV system size: 8.25KW DC, 7.6KW AD CEC with 25 PV Modules and 25 microinverters, 2 Tesla PowerWall Battery 13.5KWh, 3 sub-panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3846	15041-20001-05654	6455 W SANTA MONICA BLVD	90038	13	144B185   631	5533009032	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM			PC Approved	12/29/2015 12:00:00 AM	ADDRESS	34.09087	-118.3306	Revisions to approved set of plans.  Changes made to lighting and lighting controls layout along with relocation of panel.  PC FOR POWER AND ENERGY. TENANT IMPROVEMENT AND  CHANGE OF USE FROM POST OFFICE SORTING STATION TO VETINARY CLINIC. TOTAL AREA  8950 SQ FT.BUILDING APP # 15016-10000-00422.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3847	14041-20000-33368	16780 W OAK VIEW DR	91436	5	168B137   476	2289022015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2014 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.15607	-118.49838	"""0$ permit fees due to senate bill 1222""pv1install roof mounted pv system sized 10.8kw interconnected with msp.(60) wanxiang solar modules wxs180s(2) powered p6000 inverters"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3848	14041-20000-16736	16935 W MAYALL ST	91343	12	204B133   448	2685020005	P-1L, RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.25396	-118.5013	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3849	14041-10001-25070	5520 N KESTER AVE	91411	4	174B149  1026	2249028003	[Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.1708	-118.45723	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. MAIN PANEL 400 AMPS.(9) KYOCERA KD250(1) SOLAREDGE # SE3000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3850	17041-10000-38714	6765 W SELMA AVE A2	90028	13	148-5A185 252	5547013015	C4-2	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.09981	-118.33796	PC FOR A NEW FIRE ALARM SYSTEM FOR BUILDING A2 (BLDG 1 OF 2). NOTE, TWO FIRE ALARM SYSTEMS ARE UNDER ONE SET OF PLANS, ONE FIRE ALARM FOR EACH BUILDING. SCOPE INCLUDES 195 FA DEVICES AND 3 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3851	19041-10000-13323	7900 S LOYOLA BLVD	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM			PC Info Complete	05/06/2019 12:00:00 AM	ADDRESS	33.96604	-118.41693	Energy plan check for an office T.I located in a (2) story building. Scope inlcudes new lighting and equipment with a total area of 2135-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3852	19041-10000-44422	5016 N CASPAR AVE	90041	14	162A223   243	5686004014	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	11/09/2020 12:00:00 AM	ADDRESS	34.13749	-118.21305	INTERIOR REMODEL TO (E) CHURCH ACTIVITY CENTER AND ADD NEW ADA TOILET, RAMP AND ELEVATOR PER ENGINEERING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3853	14041-10000-15855	12128 W VENTURA BLVD	91604	2	162B165   169	2369014005	C2-1VL, R4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.14334	-118.39618	"TITLE 24 PLAN CHECK ONLY.  TOTAL AREA = 3,476 SQ. FT.A RETAIL M OCCUPANCY SPACE IN A CORE AND SHELL PREVIOUS M OCCUPANCY SPACE.  THE NEW SPACE WILL BE AN EXTENSION OF THE EXISTING ""FREE PEOPLE"" SPACE NEXT DOOR.  THIS WORK INVOLVES A RENOVATION OF THE EXISTING SPACE.  BUILD OU OF THE NEW SPACE, NEW STOREFRONT, HVAC, ELECTRICAL, AND PLUMBING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3854	14041-10000-08320	4716 E DEL PASO CT	90032	14	135A231    60	5215029008	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.06544	-118.18291	PV1 2.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(10)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX OP300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3855	12041-20001-15236	1751 S WESTWOOD BLVD	90024	5	129B153   370	4324028047	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.05089	-118.43821	Modification to previously approved set of plans located in a METHANE ZONE.  New switchboard tapped off the old swbd and relocate all loads to the new swbd.  (Applicant has inserted the replacement sheets into the old set and left the old sheets in)<<<<T.I. change use from retail to grocery store (Sprouts) in an existing building.  Relocate panel, add new branch circuits, and lighting.  Plan check for power and energy.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3856	17041-20001-02869	1520 W JAMES M. WOOD BLVD System B	90015	1	130-5A205 328	5137004029	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	34.05009	-118.27201	4/20/2017Changes to an pproved set of plans.  Changes include modules rated at 335Watts. This is plan check only.(((pv2install roof mounted pv system sized 3kw interconnected with msp.This is system B)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3857	17041-10000-18752	1026 W 34TH ST	90731	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.02414	-118.28985	PC for power only for new equipment installed at USC pool facility. PC for 2 new chillers, 4 new pumps and one cooling tower.  Total load is more than 700 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3858	15041-10000-02969	11820 W ART ST	91352	6	195B169    36	2631023008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.23468	-118.38989	PV1 STANDARD PLAN RESIDENTIAL. 14 MODULES AND 1 INVERTER. 4.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3859	18041-10000-47335	1530 S OCEAN FRONT WALK	90291	11	106-5A143  65	4226001903	OS-1XL-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	33.98684	-118.47372	New Fire system in Venice Beach Police Substation, install (1) FACP, (32) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3860	15041-20000-06153	14150 W VAN NUYS BLVD #101	91331	6	201B153    32	2645021001	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Issued	03/03/2015 12:00:00 AM	ADDRESS	34.25162	-118.4416	Plan check for energy only. Using 2008 Title-24 standards due to building permit being submitted prior to July 1st, 2014. T.I. and change of use for existing unit to yogurt shop, new lighting system for space. 427sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3861	12041-10000-00580	3760 S CENTINELA AVE	90066	11	114B153  1222	4248032038	P-1, P-1VL, [Q]C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.0047	-118.43412	PLAN CHECK T24 ENERGY FOR TENANT IMPROVEMENT OF EXISTING KITCHEN WITHIN MARKET.  LIGHTING TIED TO EXISTING LIGHTING CONTROL PANEL. PERMIT FOR NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3862	18041-20000-41160	21700 W OXNARD ST Suite 960	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for Title 24 only. Project site is the 9th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,055 sq. ft.Note: Building application has been generated under 18016-10000-28987	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3863	18041-20000-39039	13217-13221 N GLADSTONE AVE	91342	7	225B157   700	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	04/12/2022 12:00:00 AM	ADDRESS	34.31106	-118.42896	Tenant improvement for shopping market.  New and relocated distribution using (E) 2000A 208Y/120V service.  Associated building permit under 18016-20000-33057.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3864	16041-10000-13630	1115 1/2 S HOPE ST	90015	14	127-5A207 258	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.04207	-118.26356	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (RETAIL SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1020 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3865	17041-10000-17694	1925 S CENTURY PARK EAST MotorCourt	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.06066	-118.41426	PC for energy only, Indoor Title 24. New lighting and power only in motor court restrooms. Load does not exceed 400 amps. Area: 303 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3866	10041-20000-13772	21424 W SHERMAN WAY	91303	3	183B105   199	2111028004	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	07/22/2010 12:00:00 AM		Permit Finaled	03/18/2011 12:00:00 AM	ADDRESS	34.20085	-118.59857	installing lighty in a market. energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3867	15041-10000-38362	3350 W SAN FERNANDO ROAD	90065	13	153B209   153	5458003010	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.11835	-118.24962	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3868	15041-10000-07102	10870 W WELLWORTH AVE	90024	5	132B153   650	4325009020	R1-1	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Expired	04/04/2017 12:00:00 AM	ADDRESS	34.05702	-118.44203	PV1 4.2KW ROOF MOUNTED SYSTEM INCLUDING (1)  ABB-PV1-4.2KW-OUTD INVERTER AND (20) KYOCERA 260	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3869	19041-10000-38598	25111 S NORMANDIE AVE	90710	15	036B197   237	7413007037	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	33.79612	-118.29765	REMOVE HID FIXUTRES AND REPLACE WITH NEW LED FIXUTRES -T/24 ONLY INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3870	16041-20000-45187	2300 E PACIFIC COAST HWY	90744	15	033B217     3	7428008905	M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.79043	-118.22853	Plan check for power only. Project site is an existing industrial location. Project scope is installation of equipment within a classified hazardous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3871	17041-20000-10403	15303 W VENTURA BLVD Suite 1080-1090	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 920 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3872	18041-10000-16897	7400 W MELROSE AVE	90046	5	141B181   606	5526019001	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.08346	-118.35126	REPLACE AN EXISTING DAMAGED SERVICE EQUIPMENT WITH NEW PANELS AND INSTALL A NEW DISCONNECT SWITSH TO ANOTHER SERVICE IN A MIXED USE BUILDING.  ADD ONE NEW AC UNIT IN ONE UNIT.ELECTRICAL PLAN CHECK WAS REQUESTED BY LADBS ELECTRICAL INSPECTOR AND APPLICANT.<<<NEED LETTER OF JUSTIFICATION FROM LADWP FOR MULTIPLE SERVICES IN THE BUILDING>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3873	16041-20000-37316	6222 W ORANGE ST	90048	5	135B177   458	5510027019	[Q]R3-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	06/24/2017 12:00:00 AM	ADDRESS	34.06425	-118.36419	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3874	19041-20000-28010	467 S LEVERING AVE pv1	90024	5	135B149   247	4366029016	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.06764	-118.4569	pv1install roof mounted pv system sized 6.9KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3875	17041-10000-35351	1135 N SYCAMORE AVE	90038	4	144B181   388	5531013025	R3-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Issued	10/03/2017 12:00:00 AM	ADDRESS	34.09168	-118.34292	PC FOR OUTDOOR T-24, REPLACE EXISTING FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 26,950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3876	18041-20000-44365	15273 W SUNSET BLVD 5-113A	90272	11	129B125   863	4410007009		West Los Angeles				2625.01	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	04/05/2019 12:00:00 AM		Issued	04/05/2019 12:00:00 AM	ADDRESS	34.04688	-118.52497	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3877	18041-20000-16610	6301 N OWENSMOUTH AVE 5th Floor	91367	3	177B105   123	2146029016	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Issued	07/11/2018 12:00:00 AM	ADDRESS	34.18467	-118.60176	Plan check for Title 24 only. Project site is the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 20,038 sq. ft.Note: Building application has been generated under 18016-10000-12814	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3878	15041-10000-38372	616 S ST PAUL AVE 1-225	90017	1	130-5A207  76	5143026008	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			11/13/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.05284	-118.26109	$0 PERMIT FEE PER SENATE BILL 1222.PV2 ROOF MOUNTED SYSTEM 484 MODULES AND 6 INVERTERS. TOTAL SYSTEM SIZE 126 KW. 3 PHASE SOLAR SYSTEM AT 1000 VDC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3879	17041-20000-25210	16944 W SAN FERNANDO MISSION BLVD	91344	12	210B133   994	2683028034	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.2718	-118.50105	Remodel first floor of bank.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3880	18041-10000-48548	10281 W PICO BLVD	90064	5	129B161   327	4315014059	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.0486	-118.41341	NEW FIRE ALARM SYSTEM FOR (E) CORE AND SHELL, 88 FA DEVICES, 1 FA PANELS,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3881	14041-20000-00634	23255 W ARMINTA ST PV1	91304	12	189B093   419	2020024004	RE11-1	South Valley		West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			Reviewed by Supervisor	01/21/2014 12:00:00 AM	ADDRESS	34.21337	-118.63435	New ungrounded PV System for an existing single family dwelling with two inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3882	15041-20000-22641	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	11/02/2016 12:00:00 AM		Issued	11/02/2016 12:00:00 AM	ADDRESS	33.94955	-118.38214	TI to existing commercial building (bottling facility). Plan check for power and energy. Adding new lighting including emergency. Total sqft. 3,720.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3883	18041-20002-30825	18460 W ROSCOE BLVD 1st flr	91325	12	192B125   934	2102001018	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.22046	-118.53569	4/20/2019changes to an approved set of plans.  changes to first floor lighting and energy calculations.  this is plan check only. changes noted delta 4. (((4/4/2019changes to an approved set of plans.  changes noted delta 2.  changes to the looby floor lighitng. New energy calculations and lighting layout.  this is plan check only.)))  ((((Plan check for Title 24 only. Project site is a 1st floor corridor of an existing commercial building. Project scope is an interior remodel. Total lighting area = 1,281 sq. ft.Note: Building application has been generated under 18016-20000-26164))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3884	13041-20000-31720	19600 W WELLS DR PV1	91356	3	171B117   372	2175011004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2013 12:00:00 AM			Reviewed by Supervisor	11/15/2013 12:00:00 AM	ADDRESS	34.16395	-118.56074	PV System for a new single family dwelling using Enphase M215.  Rooftop	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3885	11041-10000-22012	3700 N COLDWATER CANYON AVE	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.13809	-118.41286	"T-24 and emergency lighting plan check for NEW MEZZANINE WITHIN EXISTING LIBRARY; NEW SECOND FLOOR ""BRIDGE"" CONSTRUCTED BETWEEN EXISTING BUILDINGS"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3886	19041-20000-00360	756 N TALBOT LANE	90026	13	141A203   497	5401019047	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Apartment			01/04/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.08063	-118.27575	Plan check for power only for small lot sub-division 12 units Methane Zone, 1200A Service feeding 12 units. Electrical permit pulled under Combonation Permit for individual address B#17010-10001-02316.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3887	18041-20000-39376	10390 W SANTA MONICA BLVD	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.05734	-118.42365	ti to an existing commercial building adding new lighting new controls to new panel.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3888	12041-10000-07660	823 E 31ST ST	90011	9	118-5A207 389	5128015008	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Issued	07/24/2012 12:00:00 AM	ADDRESS	34.01683	-118.26099	Combining single phase and three phase services to a single 600A 240V 3PH 4W SERVICELOADS REMAINED THE SAME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3889	14041-20000-26720	12663 W SANDHILL LANE Unit #3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97743	-118.41479	PV2Install roof-mounted solar array on Unit #3 of commercial building. Each of the 3 Units will have their own solar array, interconnecting in their respective unit panels. All Unit panels fed off of the same 400A distribution board.System size: 3kW.(1) PVI 3.0-OUTD-S-US-A transformerless inverter(12) SunPower SPR-230NE-BLK-D pv modules (two strings of 6)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3890	13041-10000-05013	20600 W VENTURA BLVD SOUTH	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			02/27/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	FIRE ALARM SYSTEM FOR APARTMENT COMPLEX. MULTI FAMILY DWELLING. TOTAL DEVICES 882 AND 2 PANELS. THIS APPLICATION IS FOR THE SOUTH BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3891	15041-20000-05183	612 S FLOWER ST 1st Floor	90017	14	129A209   264	5144005124	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.0497	-118.25759	Plan check for Title 24 energy only. Tenant improvement to existing restaurant on the first floor of a high rise building. New lighting including emergency. Total lighting area = 7,307 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3892	16041-10000-07111	2553 N SUMMITRIDGE DR	90210	5	156B157   404	4386012028	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM			PC Info Complete	04/05/2016 12:00:00 AM	ADDRESS	34.12113	-118.42132	PC FOR POWER ONLY. SCOPE INCLUDES REPLACING AN EXISTING 600A 120/240V 1 PHASE  SERVICE WITH AN 800A 120/208V 3 PHASE SERVICE, NEW 800A MAIN SWITCHBOARD, AND NEW 600A DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3893	19041-20000-12917	18811 W BEECHTREE LANE	91326	12	207B121   418	2728029010	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.26402	-118.54289	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 14.85 KW DC/12KW AC. SCOPE OF WORK INCLUDES (45) 330W PANASONIC PV MODULES WITH SE P400 OPTIMIZERS, (2) SE6000A-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3894	12041-10000-07884	431 W 7TH ST 3rd floor	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.04654	-118.25516	Lighting change to an existing restroom on the 3rd floor of an existing commercial building.  Load is less than 200A. PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3895	16041-20000-05737	6649 N BOBBYBOYAR AVE	91307	12	180B093   299	2036003008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.19117	-118.63271	Plan check for PV roof mounted system. System size: 6.0kW with 25 modules and 1 inverter(6.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3896	18041-10000-39968	5600 W CENTURY BLVD	90045	11	090B169    36	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	33.94469	-118.37969	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY. Total sq. ft. 144200.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3897	14041-20000-11044	3743 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.01873	-118.35577	T.I. to healthcare facility (Dental).  Install subpanel, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3898	12041-10000-10902	4550 W PICO BLVD C1-301	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	PLAN CHECK POWER AND ENERGY FIRST TIME TENANT.  NEW CHIPOTLE RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3899	14041-20000-26212	19025 W NASHVILLE ST	91326	12	210B121   714	2718012012	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.26848	-118.54718	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING SINGLE STRING W/ 21 MODULES. SYSTEM USES POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3900	17041-20001-04646	18928 W VICTORY BLVD	91335	3	180B121   606	2128005044	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	34.18641	-118.5459	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.24KW.  ADDITION  TO EXISTING SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3901	18041-10000-42781	4411 W SLAUSON AVE	90043	08	108B181   695	5008015044	C1.5-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Closed	01/26/2024 12:00:00 AM	ADDRESS	33.98904	-118.35222	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3902	14041-10000-05313	2130 E 1ST ST 1st floor	90033	14	127-5A223 122	5183008901	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.04433	-118.21291	Ti in an existing commercial Bldg. EPC is for T24 & emergency lighting. (Fed. credit union office)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3903	18041-10000-24591	333 S HOPE ST 1400	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC FOR OFFICE TI  IN A HIGH RISE FOR TITLE 24 ENERGY ONLY.TOTAL AFFECTED AREA 20,330.5 SQ.FT SCOPE INCLUDES NEW LIGHTS AND CIRCUITS. B# 18016-10000-21037	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3904	19041-20000-48733	2961 S HADDINGTON DR	90064	5	123B161   177	4318022003	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.03633	-118.41144	PV1. INSTALL 9.13 KW DC PV SYSTEM WITH (22) MODULES AND (2) TESLA STORAGE BATTERIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3905	15041-20002-32672	18852 W KILLOCH WAY	91326	12	216B121   169	2820015024	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM			PC Info Complete	12/14/2015 12:00:00 AM	ADDRESS	34.2912	-118.54413	Changed to approved set: relocates modules on the roof top. Module counts and system size remain the same.PC fees $0 per Senate Bill 1222.Permit under 15041-20000-32672(((PV1. Install roof mounted PV system sized 7.5 kW. Interconnected with main service panel.(30) SolarWorld 280 Modules(30) Enphase Energy M250 Microinverters)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3906	14041-20000-16604	11391 N GLADSTONE AVE	91342	7	213B169   881	2530006015	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.27702	-118.39218	PV1.  Install 3.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3907	13041-10000-25104	22808 S LOCKNESS AVE	90501	15	045B193   407	7347017046	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	33.8187	-118.30644	TITLE 24 PLAN CHECK ONLY. 1 STORY. 6325 SQFT. EMERGENCY LIGHTING EXISTING TO REMAIN. WAREHOUSE. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3908	10041-10000-19462	130 W COLLEGE ST	90012	15	033B213   301	7425041006	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	02/03/2011 12:00:00 AM	ADDRESS	34.06296	-118.23493	SERVICE UPGRADE TO 600 AMP FOR INSTALLATION OF 100 ELECTRICAL OUTLETS (208V, 2P, 1100W EACH) FOR DIESEL BUSSES IN A PARKING LOT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3909	14041-10000-11137	222 W UNIVERSAL TERRACE PKWY	91608	4	162B177   344	2424044023	[Q]C2-1-SN	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.13886	-118.35789	permit to be pulled at EPC counter only. plan check for energy . less than 400 A per applicant. Lighting for street and for UNDERGROUND TUNNEL FOR PEDESTRIAN/GOlF CART ACCESS (NO VEHICULAR ACCESS ALLOWED) [see bdlg#14020-10000-00631].	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3910	17041-20001-42919	17660 W VENTURA BLVD	91316	5	171B129   388	2290010002	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.16214	-118.51822	PLAN CHECK ONLY, REVISION TO APPROVED SET, CLOUDED DELTA 5 CHANGES ONLY, CHANGE IN PANEL SCHEDULE, CHANGE IN EQUIPMENTS, UPDATE TO SITE PLAN, UPDATE TO LIGHT FIXTURE SCHEDULE, ADDITION OF NOTES, POWER, LIGHTS AND LIGHT CONTROLS*ORIGINAL*FULL PC FOR POWER AND ENERGY FOR A NEW RESTAURANT. SCOPE INCLUDES A NEW1200A 120/208V 3 PHASE 4 WIRE SERVICE/DISRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 17550 SQ. FT.  B#17010-10000-04695	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3911	18041-10001-01707	235 N HOOVER ST	90004	13	139-5A201 199	5501004006	R4-1	Central	Wilshire	Rampart Village	YES	2111.21	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM			PC Approved	01/29/2020 12:00:00 AM	ADDRESS	34.07568	-118.28356	PC FOR CHANGES DUE TO DESIGN CHANGE. SCOPE INCLUDES CHANGE TO SERVICES SIZE PER DWP LETTER.CHANGES IN DISTRIBUITION CONFIG AND LOADING ARRANGMENT. ADDITIONAL PANELS AND CIRCUITS. =INCLUSION OF OUTDOOR LIGHTS AND AMMENITIES AREA WITH T24 REVISIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3912	17041-10000-04767	3524 E 16TH ST	90023	14	117A225   213	5192008033	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.01491	-118.20201	CHANGING OUT OLD FIXTURES FOR MORE ENERGY EFFICIENT. PC FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA IS 4700 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3913	15041-10000-12258	3983 S BRONSON AVE	90008	10	114B185    68	5033005009	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.01229	-118.33285	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.9KW INTERCONNECTED WITH MSP.(18) ENPHASE 215 MICROINVERTERS(18) LG MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3914	18041-20000-29979	11754 W SAN VICENTE BLVD	90049	11	129B145    93	4265018017	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.05289	-118.46792	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to a restaurant. Total lighting area = 1,925 sq. ft.Note: Building application has been generated under 18016-10000-23338	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3915	19041-10000-36289	12105 W PICO BLVD	90064	11	123B149  1035	4259032025	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.02939	-118.4506	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3916	13041-10000-02830	16501 W VENTURA BLVD Suite 400	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	02/08/2013 12:00:00 AM	ADDRESS	34.1578	-118.49275	T24 for existing 5 story office building. Existing panels. 11460 sqrft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3917	16041-20000-39212	7832 N RUDNICK AVE	91304	3	189B101   598	2012016015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Refund in Progress	10/20/2017 12:00:00 AM	ADDRESS	34.21299	-118.61242	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3918	14041-10001-21149	12347 W HUSTON ST	91607	2	168B165   181	2356026020	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.15951	-118.40248	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 13.39 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(57) MODULES: SHARP NU-U235F1 (2) INVERTER: POWER-ONE AURORA PV1-6000-OUTD-US-Z-D>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3919	16041-10001-06786	15838 W BAHAMA ST	91343	12	195B141   286	2672007006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.23272	-118.47775	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 17.658 KW DC/15200 W AC ROOD-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(54) MODULES: SUNPOWER SPR-327 -NE WHT-D(3) INVERTERS: POWERoNE pvI-6000& 5000 & 4200 W-OUTD-US-A>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3920	15041-10000-06406	600 WORLD WAY TERM6 LEV-1  #681	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM			PC Approved	03/04/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	EXISTING RETAIL SPACE REMODELED TO A STARBUCKS COFFEE SHOP IN TERM 6 LEV1 SPACE681PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3921	15041-10000-23563	808 N KENTER AVE	90049	11	138B137   336	4494022017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Expired	08/17/2017 12:00:00 AM	ADDRESS	34.07347	-118.49014	PV1INSTALL ROOF MOUNTED PV SYSTEM CENTRAL STRING INVERTER STANDARD PLAN.  SYSTEM SIZE 7.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3922	12041-10000-26889	22937 W CANTLAY ST	91307	3	186B097   970	2021019016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.20201	-118.62686	6.0 kw roof mounted PV for a single family using x-formerless INV. (PV-1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3923	19041-10000-25567	14919 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.29465	-118.45593	(PV1) Addition of (1) 3kW inverter with (4) modules, and (1)Tesla 13.5 kWh ESS.  Scope includes adding 1.2KWdc / 1.071 KWac to an existing PV system. Total PV System size with new and existing is 6.8 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3924	16041-10000-20293	5827 S MEADOWLARK PL	90094	11	102B161  1272	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	33.97502	-118.41578	NEW F.A. FOR APT. INCLUDING 46 DEVICES 1 PANEL  2 COMM. PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3925	19041-20000-30932	8536 N FARRALONE AVE	91304	12	192B101    80	2010017015	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.22597	-118.61094	PV1.  Install 6.75 kW DC / 6.0 kW AC roof mounted grid tied PV system.  (18) modules with 6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3926	15041-10003-13263	15927 W VENTURA BLVD	91436	5	168B141   544	2261021007	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Info Complete	11/08/2016 12:00:00 AM	ADDRESS	34.15615	-118.48017	10/06/16Changes to an approved set of plans. All changes are clouded under delta 5. Changes include replacing pendant light fixtures from 4 watt rated fixture to 50W rated fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3927	18041-20000-39876	601 S FIGUEROA ST 2130	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing space office T.I. high-rise building. Total area: 3005 sq ft. B#18016-10000-31431	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3928	10041-20000-25802	7000 W HOLLYWOOD BLVD 13th Floor	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM			PC Info Complete	01/25/2011 12:00:00 AM	ADDRESS	34.10137	-118.34182	Plan check T-24 Energy (general/emergency) lighting for common areas of 13th Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3929	12041-10000-05083	321 N LARCHMONT BLVD	90004	4	138B189   330	5523020038	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	06/15/2012 12:00:00 AM	ADDRESS	34.07682	-118.32384	REMODEL RESTROOMS ON FLOORS 7 AND 10. NEW LUMINAIRES AND SWITCHES; EXISTING ENERGY MANAGEMENT SYSTEMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3930	14041-10000-15650	2605 S LA CIENEGA BLVD	90034	10	123B173   463	5065006004	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Issued	02/24/2015 12:00:00 AM	ADDRESS	34.03443	-118.37783	PLAN CHECK FOR 600A SERVICE UPGRADE TO EXISTING BODY SHOP AND SOME NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3931	13041-10000-07994	8985 W VENICE BLVD CB-2	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.02733	-118.39241	refer to 13041-10000-07994  for plan checkRENOVATION OF EXISTING STARBUCKS. CHANGE IN LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3932	14041-10001-05702	1412 N CAMPUS ROAD	90042	14	156A223   137	5476019017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1834.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.12274	-118.21064	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(10) MODULES: TRINA SOLAR TSM-250PA05.18(1)TRANSFORMERLESS INVERTER:  SOLAREDGE SE3000A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3933	13041-10000-33296	2251 E WASHINGTON BLVD	90021	14	118-5A217 120	5167019043	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	11/27/2013 12:00:00 AM	ADDRESS	34.01912	-118.23149	PLAN CHECK FOR TITLE 24, ENERGY ONLY.REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. AREA 16025 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3934	19041-10000-39589	1411 W 190TH ST Suite 600	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	33.85852	-118.30317	PLAN CHECK ONLY FOR ENERGY ONLY, SCOPE OF WORK IS INSTALLING LIGHTS IN AN OFFICE SPACE. TOTAL AFFECTED AREA IS 3141 SQFT. NOTE PERMIT FEES HAVE BEEN PULLED UNDER 19041-40000-25231	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3935	19041-10000-48189	3704 S WESTWOOD BLVD	90034	5	117B161   248	4252028028	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			11/21/2019 12:00:00 AM			Reviewed by Supervisor	12/03/2019 12:00:00 AM	ADDRESS	34.01919	-118.41119	PC FOR POWER AND ENERGY. SCOPE INLCUDES A NEW 120/240V 1 PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 14991SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3936	19041-20000-04250	10245 N QUILL AVE	91040	7	204B189   746	2560022003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.25551	-118.31682	Plan check for PV roof mounted system and battery energy storage, PV System size: 5.85KW with 18 PV Modules and 1 inverter 5.2KW with 1 Tesla battery 13.5KWH.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3937	14041-10001-23310	6447 W WYNKOOP ST	90045	11	102B165   536	4110023010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Issued	09/18/2014 12:00:00 AM	ADDRESS	33.97415	-118.4027	((9/18/2014- Changes made to approved set, added 2 modules and changed orientation on roof))Standard plan, 6KW AC PV1 roof-mounted system including (25) modules and one SMA -6000TL inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3938	11041-10000-08448	10250 W SANTA MONICA BLVD #1250	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			Verifications in Progress	06/30/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3939	17041-10000-19753	6836 N LANKERSHIM BLVD	91605	2	183B169   531	2320011006	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.19506	-118.38757	REPLACE  LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3940	16041-10000-35521	5750 W WILSHIRE BLVD SUITE 105	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	FULL PC FOR POWER AND ENERGY FOR A NEW FITNESS CLUB WITH AN ACCESSORY SPA, MASSAGE, CAFE, AND RETAIL SPACES ON THE GROUND FLOOR OF AN EXISTING 6 STORY OFFICE BUILDING. NEW CONNECTED LOAD > 400A. TOTAL AFFECTED AREA IS 23,450 SQ. FT.  BUILDING. B#16016-10000-24017	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3941	18041-20000-06175	201 N OCCIDENTAL BLVD	90026	13	138A203   239	5156017023	R3-1	Central	Westlake	Rampart Village	YES	2086.10	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.07228	-118.27856	PLAN CHECK FOR POWER ONLY FOR EXISTING MOTION PICTURE PRODUCTION SOUND STAGE W/ ACCESSORY OFFICES. NEW SERVICE GOING FROM 1200A 120/208V TO 1200A 480/277V,  RECONNECT EXISTING EQUIPMENT AND ADD NEW EQUIPMENT TO NEW SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3942	14041-10000-21305	21051 W SUPERIOR ST	91311	12	201B105   175	2746003003	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.24647	-118.59228	Remove HID light fixtures and replace with new fluorescent fixtures. T24 plan check. Area = 6016 sq. ft. 14 units	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3943	15041-10000-43022	218 S OCCIDENTAL BLVD	90057	13	136-5A201 153	5155013004	R4-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Apartment			12/21/2015 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	03/21/2023 12:00:00 AM	ADDRESS	34.06857	-118.28128	POWER AND ENERGY FOR NEW 6 STORY 47 UNIT APARTMENT BUILDING WITH 2000A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3944	19041-10000-20743	920 W DOWNEY WAY #101 #103-#105	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.02063	-118.28879	PC FOR T24 ENERGY ONLY. FOR RESEARCH LAB SPACE AT USC ON THE FIRST FLOOR IN ROOM NUMBERS 101, 103 & 105. SCOPE INCLUDES NEW LIGHTS, CIRCUITS AND PANEL. TOTAL AFFECTED AREA 1054 SQ.FT. B#19016-10000-16395	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3945	10041-20000-12354	10960 W WILSHIRE BLVD 6TH FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	PLAN CHECK T-24 ENERGY GENERAL/EMERGENCY LIGHTING FOR OFFICE SPACE TI ON 6TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3946	17041-20001-45615	19430 W COHASSET ST	91335	3	186B117   427	2116016063	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	12/29/2017 12:00:00 AM	ADDRESS	34.20644	-118.55669	expeditepv1install roof mounted pv system sized 17.9kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3947	14041-20000-32804	9201 N OAKDALE AVE UNIT 100	91311	12	198B113   214	2761001084	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.2381	-118.56706	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND RECEPTACLES CIRCUITS TO EXISTING PANELS.  TOTAL SQUARE FOOTAGE 12482.PLAN CKHECK FOR ENERGY AND EMERGENCY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3948	11041-10000-03810	2049 S CENTURY PARK EAST 27th floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3949	18041-10001-33038	10990 W WILSHIRE BLVD #250	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.0577	-118.44711	PLAN CHECK FOR TITLE 24 ONLY FOR SUITE 250 - TOTAL AFFECTED AREA = 1620 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3950	18041-10002-24626	4538 W MELBOURNE AVE	90027	4	150B197  1172	5590022004	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Apartment			08/27/2019 12:00:00 AM			PC Approved	09/05/2019 12:00:00 AM	ADDRESS	34.10348	-118.28897	PLAN CHECK FOR A LOST SET OF PLANS FOR PV SYSTEM. NOTE:  Permit Fees are paid under the master application. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3951	16041-20000-25357	20948 W KNAPP ST BLDG 2	91311	12	198B109   211	2746009041	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.23844	-118.59063	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  THIS IS BUILDING 2 SUBFED BY  BUILDING 1.  TOTAL QUARE FOOTAGE 20411.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3952	14041-10000-34534	1361 W 190TH ST	90248	15	060B193   382	7351001020	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	33.85852	-118.3026	NEW FIRE ALARM INSTALLATION WITH 62 DEVICES  AND ONE PANEL. RETAIL WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3953	14041-20002-17764	13287 N RALSTON AVE	91342	7	225B141   172	2501002027	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	34.31289	-118.47324	Changes to an approved set of plans. Changes include the recalculated fault current calculations at equipment due to increased available fault current reported by DWP. All changes have been clouded and marked as Delta 6.*****Previous Work Description*****CHAGES TO APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF EQUIPMENT AND NEW SERVICE AND DISTRIBUTION EQUIPMENT. PLAN CHECK FOR CHANGES CLOUDED DELTA 4. NO CHANGE IN ENERGY CALCS UNDER THIS APPLICATION. FAULT CURRENT BASED ON DWP ESR. IF FAULT CURRENT FROM DWP IS GREATER THAN ESR INSPECTOR TO SEND PLANS BACK FOR FAULT CURRENT RECALC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3954	18041-20003-44434	9712 W HEATHER ROAD	90210	4	147B161    16	4352002039	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	34.10286	-118.40782	2/19/2019changes to an approved set of plans.  changes to reflect field conditions. this is plan check only.   ((((PV1.  Install 24.705 kW roof mounted grid tied PV system.  (81) modules with (2) 7.6 and (1) 5.2 kW rated string inverters.Fees $0.00 due to California Senate Bill 1222 and AB1414))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3955	19041-20000-44359	21240 W BURBANK BLVD BLDG 38	91367	3	174B105    91	2149016028	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.17307	-118.59314	TENANT IMPROVEMENT ADD NEW LIGHTS PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3956	16041-10000-25511	400 WORLD WAY Terminal 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM			PC Info Complete	07/20/2016 12:00:00 AM	ADDRESS	33.94221	-118.40701	T-24, PC FOR ENERGY ONLY. INTERIOR REMODEL AT FIS  ARRIVALS LEVEL AND   NEW EGRESS ANALYSIS. SCOPE INCLUDES NEW LIGHTS FOR CORRIDOR. TOTAL AFFECTED AREA IS 1029 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3957	19041-10000-41726	4139 N SUNNYSLOPE AVE	91423	4	165B157  1009	2373010006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.14563	-118.42729	[EPLAN] PLAN CHECK FOR 2 ESS(TESLA POWERWALL) CONNECTED TO EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3958	17041-20001-42400	4357 E SAN RAFAEL AVE	90065	1	153A223   350	5471009008	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.11212	-118.21293	Expedite fee. PV1.  Install 11.05 kW roof mounted grid tied PV system.  (34) modules with (2) 5.2 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3959	18041-10002-03991	603 E 115TH ST	90059	15	087A207   339	6072004027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Info Complete	07/25/2018 12:00:00 AM	ADDRESS	33.93021	-118.26482	Revision to approved set.  Replacing exit signs, emergency lights for path of egress with new lighting , and adding outdoor lighting. Photometric is provided.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3960	19041-20001-46254	2708 N CASIANO ROAD	90077	5	156B141   117	4378030016	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.12034	-118.47255	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED PLAN. CHANGES MADE TO ALL PAGES. ADDITION OF A SUB PANEL, CHANGE TO PV MODULE MODEL AND QUANTITY, CHANGE TO ROOF LAYOUT PAGE, CHANGE TO SIGNAGE PAGE, AND PV SYSTEM SIZE CHANGED TO 5.76 KW DC/5.04 KW AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3961	19041-20000-38103	13826 W VENTURA BLVD	91423	4	165B153   601	2266018007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.14825	-118.43402	Power and lighting for TI to commercial restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3962	17041-10001-44218	1650 S WESTMORELAND BLVD	90006	10	126B193   367	5074018004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.04303	-118.30641	EXPEDITE PER APPLICANT REQUESTPC FOR ROOFMOUNTED PV ON SFD WITH ESS SYSTEM INSTALLED (UNDER SUPP. APPLICATION).SYSTEM SIZE 3.0KWAC ADN 4.4KWDC SCOPE INCLUDES 11 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3963	12041-20001-01857	6600 N TOPANGA CANYON BLVD #1044	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM			PC Approved	03/28/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	Moved transformer from approved location on original plan (12041-20000-01857). Change to emergency lighting (added one bugeye and deleted emergency can lights).  Specified fusible disconnect for secondary side of transformer. T-24 lighting plan check for remodeled store 1044.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3964	16041-10000-37977	1227 W 187TH ST	90248	15	060B197   309	6109011007	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	33.86137	-118.29532	PC FOR ROOF MOUNTED PV. SYSTEM SIZE IS 3.3KWACSCOPE INCLUDES 14 PANELS (TRINA SOLAR TSM-255 PD05.05)10 OPTIMIZERS-SOLAREDGE P3001 INVERTER (SOLAR EDGE SE3000A-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3965	15041-10000-01952	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.07196	-118.24719	Pc for T24 only. Renowation to dodger stadium. Total area 7200 sq ft. DOGOUT CLUB. Note. no new panel installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3966	13041-10000-33035	6208 N DENNY AVE	91606	2	177B177   287	2414011013	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.18324	-118.36471	PV1, Install 6.5 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (26) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3967	19041-20000-32322	6080 W CENTER DR STE 725	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	T24 PLAN CHECK FOR EXISTING COMMERCIAL HIGH RISE SUITE 725. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 3184 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3968	15041-20000-39255	2529 W SAN FERNANDO ROAD	90065	1	150B213   464	5457008028	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.10756	-118.24057	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE/SHOP). INTERIOR/EXTERIOR REMODEL AND FIRE DAMAGE REPAIR. SCOPE INCLUDES NEW PANELS, BRANCH CIRCUITS, AND NEW LIGHTING. TOTAL AREA IS 5410 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3969	19041-10000-52800	1164 S DACOTAH ST	90023	14	120A223    88	5190010900	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	04/20/2022 12:00:00 AM		Issued	04/20/2022 12:00:00 AM	ADDRESS	34.02419	-118.21008	INSTALLING A 15HP CARBON SCRUBBERS AND OTHER LOADS IN HAZARDOUS, CLASS I - DIVISION 2 AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3970	13041-10001-29449	11419 N MONTALCINO WAY	91326	12	213B109   412	2701068023	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.27907	-118.58671	expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3971	13041-10000-35966	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	33.9867	-118.44159	PLAN CHECK FOR POWER AND ENERGY. TI FOR A STORE.  EXISTING TENANT, MAIN SLD WAS PROVIDED FOR MAIN LAOD.  FA ALARM VARIANCE WAS SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3972	18041-20000-37211	5555 W MANCHESTER AVE	90045	11	096B173   109	4127024029	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	07/29/2022 12:00:00 AM	ADDRESS	33.96007	-118.37803	Plan check for power and energy for new 7 story Self-Storage 800A  277/480V. B#17016-10000-06774	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3973	19041-20000-13272	15273 W DE PAUW ST	90272	11	126B125   822	4412028029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.03865	-118.52584	INSTALLATION OF (2) 5KW TESLA POWERWALL BATTERIES, AND (2) 125A SUB PANELS TO A EXISTING SFD WITH A EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3974	14041-20000-05195	5816 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.97382	-118.41957	ROOF-MOUNTED,PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3975	15041-10000-37399	4700 W SUNSET AVE FLR 2-6	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	PIN	34.09779487	-118.29202139	TI TO AN EXISTING COMMERCIAL BUILDING.  REPLACING EXISTING FIXTURES WITH LEDS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOATGE 1996.  SCOPE OF WORK TO BE PERFORMED IN FLOORS 2 THRU 6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3976	10041-10000-06412	3415 S SEPULVEDA BLVD 10th Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	08/23/2010 12:00:00 AM	ADDRESS	34.02055	-118.42347	"Plan check T-24 Energy (general/emergency) lighting on the 10th floor TI. ""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3977	19041-10000-44514	10866 W WILSHIRE BLVD	90024	5	132B153   457	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	06/01/2022 12:00:00 AM		Permit Finaled	07/20/2023 12:00:00 AM	ADDRESS	34.05907	-118.442	Replacing existing lights with new lights in the lobbies, hallways & common areas of the 1st through 15th floors. PC FOR TI T-24 ENERGY. AFFECTIVE AREA 25,204 sqft .***Reference Only: Building Permit # 19016-10000-28728LIGHTING FOR COMMON AREAS COVERING MULTIPLE FLOORS.***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3978	19041-10000-31975	21255 W BURBANK BLVD SUITE 120	91367	3	174B105    87	2149019018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLAN CHECK FOR A TI TO AN EXISTING FIRE ALARM SYSTEM. SCOPE OF WORK IS ADDING DEVICES AND BATTERIES TO EXISITNG FIRE ALARM SYSTEM SPANNING THREE FLOORS. THIS IS THE FIRST FLOOR PORTION CONSISTING OF 25 DEVICES, AND ONE BATTERY. NOTE ALL FLOORS HAVE BEEN SEPARATED INTO THREE APPLICATIONS, ALL HAVE BEEN APPROVED BY FIRE. THE FIRST FLOOR IS UNDER 19041-10000-31975THE SECOND FLOOR IS UNDER  19041-10000-38943THE THIRD FLOOR IS UNDER 19041-10000-38944	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3979	19041-10000-09706	755 S SPRING ST 1st Flr	90014	14	127-5A211 157	5144015018	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.04336	-118.25369	TI FOR TWO 2 NEW RESTROOMS AND A SERVICE CORRIDOR IN THE COMMON AREAS OF THE FIRST FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BUILDING PERMIT: 15010-10024-00326	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3980	13041-10001-30880	3155 N DONA MARTA DR	91604	2	159B173   649	2380022014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			Corrections Issued	02/06/2014 12:00:00 AM	ADDRESS	34.12842	-118.37719	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0. Application abandoned per applicant HAMZA JACQUES on 2/6/2014 - mt.Changes to approved set of plans: moved meter location. needs thwn-2, #6 GEC, and signature.original description: PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.6KW AC USING MICROINVERTER STANDARD PLAN. ENPHASE M215. TOTAL OF 40 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3981	19041-20000-52098	5400 N CARPENTER AVE #1-16	91607	2	171B169   101	2348010026	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM	03/17/2023 12:00:00 AM		Issued	03/17/2023 12:00:00 AM	ADDRESS	34.16881	-118.39087	FULL plan check for power and energy. Scope of work includes new 800A Service, with a residential 600Amp,1ph, 3W switchboard and common area 400Amp,3ph,4W switchboard.  New lighting, circuits, 16 unit panels and common area panels. Total area: 11715 sq f	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3982	16041-10000-20055	713 W 49TH PL	90037	9	111A201   191	5018023053	RD2-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	33.99807	-118.2861	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(8)CANADIAN SOLAR SOLAR CS6P-260P(1)INVERTER SMA SB-3000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3983	14041-20001-03224	2749 W LOMPOC ST	90065	14	160-5A219 293	5683019014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM			PC Approved	03/05/2014 12:00:00 AM	ADDRESS	34.13231	-118.22598	((Expedite fees))PV1 TRANFORMERLESS SYSTEM. USING POWER OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3984	19041-10000-13101	4327 S LEIMERT BLVD	90008	10	114B185  1134	5024019018	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Issued	06/19/2019 12:00:00 AM	ADDRESS	34.0049	-118.33048	NEW LIGHTING SYSTEM FOR A PARKING LOTPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3985	14041-20000-24836	7010 S HOOVER ST Unit #4	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #4. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
3986	15041-10000-29651	1301 W SUNSET BLVD	90026	1	138A211   245	5406014035	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley		YES	1977.00	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			Reviewed by Supervisor	11/13/2015 12:00:00 AM	ADDRESS	34.07151	-118.25037	FULL PC. POWER AND ENERGY. NEW BUILDING 26 UNITS. 3 STORIES, 7 TYPICAL UNITS. TOTAL AREA 21710 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3987	17041-10000-17422	1235 W 76TH ST	90044	8	099B197    41	6019007020	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	33.97114	-118.29753	PC FOR PV SYSTEM ROOF MOUNTED. SYSTEM USES MICROINVERTERS, 10 MODULES IN TOTAL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3988	18041-20000-15259	15821 W VENTURA BLVD #510	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.15584	-118.47812	PC for T24 only for new lighting in office TI. Installing new lights reconnected to existing circuits and receptacles. Total area 2998sqft.. B#18016-10000-12143.TENANT IMPROVEMENT; NON STRUCTURAL INTERIOR PARTITIONS.2900 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3989	17041-30001-45502	2112 S BARRINGTON AVE Bldg E	90025	11	123B149   250	4260008012	C2-1, R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Info Complete	08/29/2019 12:00:00 AM	ADDRESS	34.03531	-118.44854	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,374 sq. ft.Note: Building application has been generated under 17016-30000-14384	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3990	13041-10000-34667	2139 S WESTWOOD BLVD	90025	5	126B153   239	4322001019	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.04415	-118.43224	Remove HID light fixtures and replace with new fluorescent fixtures in existing retail space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3991	19041-20000-08647	10350 1/2 S KALMIA ST	90002	15	090A217   149	6066015094	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	33.94159	-118.23161	PV1.  Install 6.84 kW roof mounted grid tied PV system.  (19) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3992	19041-20000-26791	2845 N ROYSTON PL	90210	5	156B153   127	4382002030	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.12487	-118.43362	Plan check for PV roof mounted system and Energy storage battery, PV system size: 6.3KW with 20 PV Modules 1 inverter(5.2KW) and 1 Tesla Battery PowerWall 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
3993	13041-10000-24146	21315 W ROSCOE BLVD 1-150	91304	3	192B105   549	2779013009	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM			PC Approved	09/04/2013 12:00:00 AM	ADDRESS	34.21999	-118.59568	ASBUILT: changed switching and removed some wiring from plans. no T24 calculation changes. to 13041-10000-22409Remodel of existing recreational room, title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3994	14041-20001-03435	5240 N MEDINA ROAD	91364	3	171B105   640	2168003025	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.16436	-118.59903	((((EXPEDITE FEES)))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NOSNTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
3995	17041-10000-43210	1300 E FACTORY PL	90013	14	126A215   235	5164008031	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.03904	-118.23584	REPLACE EXISTING FIXTURES WITH LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 33800 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
3996	16041-10002-37879	14235 W VENTURA BLVD	91423	4	165B153   335	2265019007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Approved	04/14/2017 12:00:00 AM	ADDRESS	34.15022	-118.44335	Supplemental PC for a lost set (recheck). PC for T24 only including new for lights, controls and receptacles. Total area is 3310 sqft. Load under 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3997	16041-10000-06814	7314 S AVALON BLVD OFFICE	90001	9	102B205  1099	6023008004	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	PIN	33.97335974	-118.26484803	T-24, NEW OFFICE BUILDING, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 470.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3998	12041-20000-01344	21700 W OXNARD ST Suite 1450	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	02/22/2012 12:00:00 AM	ADDRESS	34.17901	-118.60179	T24 lighting plan check for room 1450 expansion, only room 1400 has new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
3999	18041-10000-24421	8440 N BALBOA BLVD 106	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	08/03/2020 12:00:00 AM	PIN	34.22359223	-118.50180382	TI in a Restaurant. First Time Tenant.Full Plan Check for Power and Energy.Building Permit# 18016-10000-20887	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4000	19041-10000-48844	10641 N GLENOAKS BLVD	91331	7	207B165   213	2536015221	[T][Q]MR1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.26253	-118.39998	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4001	12041-20000-07962	22101 W COSTANSO ST	91364	3	171B101   214	2169001001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2012 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Expired	06/02/2014 12:00:00 AM	ADDRESS	34.16777	-118.60829	4.41 kw roof mounted PV System using Enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4002	18041-20000-48301	8920 N OAK PARK AVE	91325	12	195B133   161	2690008001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.23275	-118.50531	Plan check for PV roof mounted system, system size: 4.5kW DC, 3.8kW AC with 15 PV modules and 1 inverter(3.8KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4003	13041-20001-14352	235 S SAN PEDRO ST #A	90012	14	129A213   469	5161024***		Central				2062.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.0487	-118.2424	First time tenant in a mixed use building.  Beauty Salon.  Full Plan Check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4004	16041-10000-44576	8150 N LANKERSHIM BLVD	91605	6	192B169   605	2311005001	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.21902	-118.38758	PC for energy only. Remove HID Fixtures and replace with New LED fixtures. Outdoor Ttile 24. Area: 3,250 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4005	18041-20000-01553	17064 W MINDORA CT	91344	12	216B133   258	2606022013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.28934	-118.50441	PV1.  Install new 7.92 kW DC/7.04 kW AC roof mounted grid tied PV system with center-fed panelboard connection.  (22) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4006	14041-20000-35752	6638 N LANKERSHIM BLVD	91606	2	180B169   412	2320027005	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.19161	-118.38758	Plan check for energy only. TI for office. New lighting only including emergency. 1684 Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4007	14041-10000-00463	8841 W HILLROSE ST	91040	7	207B189   581	2547004014	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.26383	-118.32549	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 7.9 KW.(37) ENPHASE M215 MICROINVERTER(37) SOLARWORLD SW250 POLY MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4008	14041-20001-02087	3601 N DELLVALE PL	91436	5	162B137   645	2293003002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.13642	-118.49531	(((Exepite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 8.8KWAC. USING SOLAREDGE OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4009	18041-20000-13148	845 S BROADWAY 1st Floor	90014	14	127-5A209 174	5144017038	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.04283	-118.25583	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,434 sq. ft.Note: Building permit has been issued under 18016-10000-08209	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4010	12041-10000-13778	6600 N TOPANGA CANYON BLVD 1050	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			Reviewed by Supervisor	07/03/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check T24 Energy/Emergency lighting for retail space TI (Tommy Bahama Space #1050)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4011	18041-10000-18996	3347 W SAN FERNANDO ROAD	90065	13	153B209   103	5458006002	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.11858	-118.24925	T-24, PC FOR ENERYG ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 36700 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4012	18041-20000-20649	1048-1050 N MANZANITA ST	90029	13	145-5A201 413	5427006028	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Apartment			06/04/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.0918	-118.2818	Plan check for fire alarm system for 9 units appartment 4 story appartment. Total fire alarm devices: 68 and 1 FACP. B#16010-30000-03599	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4013	14041-10000-10035	2448 W RIVERSIDE DR	90039	13	150A209   182	5438005017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.10515	-118.25563	ROOF-MOUNTED  1.5KW PV SYSTEM USING TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4014	11041-10000-20658	1003 E ELKGROVE AVE BLDG 43	90291	11	111B145   692	4243003038	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.00021	-118.45974	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4015	19041-10001-32231	12565 W STRATHERN ST	91605	2	189B161   358	2308010002	[T][Q]MR1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			Reviewed by Supervisor	08/27/2019 12:00:00 AM	ADDRESS	34.21585	-118.40784	Expedite FeesPV2, New rooftop mounted system, system size is 48.9 KWdc/39.2KWac. Scope of work is 127 modules (Qcell 385) with optimzers (SE P505), four inverters (3 SE11400H-US, and 1 SE5000H-US), leading to a combiner panel, terminating in a line side tap. No panel uprgrade, and service is existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4016	17041-10000-45126	15285 W SUNSET BLVD	90272	11	129B125   591	4423016007	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.04704	-118.52517	Full plan check for a first time tenant T.I . Scope includes new lighting and equipment with a new main 1200 Amp panel. Total area is 11,426 SQ FT.PER#17016-10000-37285	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4017	19041-20000-06387	3952 S BRONSON AVE	90008	10	117B185  1222	5033006011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.01323	-118.33294	PV1.  Install 4.8 kW roof mounted grid tied PV system with 9.8 kWh energy storage system.  (15) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4018	13041-20000-01558	10940 W WILSHIRE BLVD	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.05822	-118.4452	Change to lighting in an existing high-rise office building on the 21st floor.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.   Permit fees are under INSPECTION.  All circuits are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4019	17041-10000-03411	938 S LAKE ST	90006	1	130-5A203  95	5136006016	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.05283	-118.28039	PC for outdoor title 24. Removing HID fixture and replacing them with new LED ones. Area: 15,500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4020	14041-20001-02818	15935 W GRESHAM ST	91343	12	195B141   407	2672024014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.23116	-118.47966	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE1 11KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4021	13041-10001-23370	1743 S SHENANDOAH ST	90035	5	129B169  1203	4303008023	R1-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.04712	-118.38288	][][]Expedited plan check per applicant request ][][][PV1 11.13 KWdc 240V XFRMless. 1 STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-5000-OUTD-US, (42) MODULES # SOLARWORLD SW 265 MONO BLACK. UNGROUNDED SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4022	15041-20000-28299	11105 S COMPTON AVE	90059	15	088-5A213 510	6070009034	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	33.93456	-118.24641	PV1. PC FOR A NEW ROOF MOUNTED PV SYSTEM INSTALLED ON TWO STORY HOUSE. TOTAL SYSTEM SIZE 3.06KW. SUBMITTAL PER APPLICANT REQUEST.(12) MODULES-HYUNDAI HEAVY INDUSTRIES HIS-M255RG(12) MICROINVERTERS-M215-60-2LL-S2X-IG INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4023	18041-20000-36242	15352 W SUTTON ST	91403	5	166-5A145 143	2283021019	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Issued	09/21/2018 12:00:00 AM	PIN	34.14997804	-118.46927507	Plan check for a PV1 roof-mounted PV system. System size is 1.74 kWac and consists of (6) modules and (6) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4024	15041-10000-26337	11675 W SHELDON ST	91352	6	201B169   248	2537023010	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.24455	-118.38687	PLAN CHECK FOR ENERGY ONLY. REPLACING EXISTING LIGHTS ON EXISTING CIRCUITS WITH LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4025	19041-10000-34586	24330 W CLIPSTONE ST	91367	3	177B089   744	2032013054	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.17845	-118.65579	(ePlan) PLAN CHECK FOR 10.56 kW DC (8.976 kW AC) PV1 INSTALLATION CONSISTING OF 32 PANASONIC 330 WATT MODULES RACKING SPECS WITH ENPHASE IQ7X MICROINVERTER.MAIN BREAKER DERATE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4026	17041-10001-22344	19215 W INGOMAR ST	91335	3	189B117   722	2104007019	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.21211	-118.55189	Expedite fees only.       Installation of roof mounted solar PV system on existing single family dwelling.  Total system size = 11 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4027	11041-20000-04176	21700 W OXNARD ST 11th Fllor	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	06/15/2011 12:00:00 AM	ADDRESS	34.17901	-118.60179	T.I. to existing high rise building.  Install general/emergency partial of 11th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4028	18041-10000-35515	20201 S NORMANDIE AVE	90501	15	057B193     5	7351003017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	33.84855	-118.29953	NEW 800 AMP SERVICE FOR A NEW REMIDIATION SYSTEM IN A VACANT CHEMICAL FACILITY.NOTE: ALL CONNECTED LOADS ARE PORTABLE / MOVEABLE EQUIPMENT EXISTING TO REMAIN BY OTHERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4029	11041-10000-19590	926 S CROCKER ST #A;B;C-SPACES	90021	9	124-5A211 165	5132002019	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.0355	-118.24971	FIRST TENANT- TENANT OCCUPYING SPACES  A;B;C ;SHELL AND CORE ON #11041-10000-07465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4030	19041-20000-05658	7856 W FOOTHILL BLVD	91040	7	204B193   177	2559010032	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.25946	-118.30465	Interior TI and exterior lighting for (E) commercial restaurant.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4031	12041-10000-10917	4345 S GLENCOE AVE	90292	11	105B153    56	4212004015	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM			PC Info Complete	05/11/2012 12:00:00 AM	ADDRESS	33.98618	-118.43939	this is a single story office bldg. title 24 energy. emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4032	12041-20000-11448	777 S FIGUEROA ST 43rd,44th-floors	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	ADDRESS	34.04828	-118.26116	T-24 and emrgency lighting plan check for room 4453 and for suite 4313.  See inspection for fees.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4033	12041-10002-06590	810 S SPRING ST	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.04268	-118.25375	REVISIONS TO APPROVED SET OF PLANS- RELOCATE RECEPTACLES ;INCREASED LIGHTING WATTAGE ; ALL CHANGES ARE CLOUDED AND IDENTIFIED DELTA 10 CHANGES((((((((Plan check power and energy TI restaurant (Terroni Restuarant) on first floor of an high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4034	15041-10000-27152	19414 W OLIVOS DR	91356	3	168B117   213	2175007011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	09/26/2015 12:00:00 AM	ADDRESS	34.15786	-118.55549	PV1. ROOF MOUNTED ON EXISTING RESIDENTAL SINGLE FAMILY HOME.  SYSTEM SIZE IS 12.6KW. MAIN PANEL TO BE REPLACED 225 AMP MAIN PANEL(49) MODULES-REC SOLAR: REC 275TP(1) INVERTER-SOLAREDGE TECHNOLOGIES: SE5000 (240) W/ -ER-US(1) INVERTER-SOLAR EDGE TECHNOLOGIES: SE 7600A-US (240V)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4035	14041-20001-23163	7261 N CIRRUS WAY	91307	12	186B093   687	2027010022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM			PC Approved	09/04/2014 12:00:00 AM	ADDRESS	34.20206	-118.63672	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 6.6KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. DERRATING MAIN BREAKER. USING TOTAL OF 32 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4036	17041-10000-31217	4527 E MERCURY AVE	90032	14	142-5A229  71	5305009019	[Q]RE9-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.08603	-118.18964	PC for T24 only for removal of outdoor HID fixtures and replace with new LEDfixtures. Total area 5150sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4037	15041-10001-20838	5727 N FULCHER AVE	91606	2	174B173   524	2337030008	R1-1	South Valley	NORTH HOLLYWOOD - VALLEY VILLAGE	MID-TOWN NORTH HOLLYWOOD		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM			PC Approved	01/08/2016 12:00:00 AM	PIN	34.17468939	-118.37333611	01/08/16Changes to an approve set. All changes made under delta 1. Changes include relocating PV modules from detached garage to single family dwelling. (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(15) SUNPOWER MODULES(1) POWER-ONE INVERTER 4.2PLAN CHECK SUBMITTAL PER APPLICANT REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4038	19041-20000-05947	3951 N EAGLE ROCK BLVD	90065	13	156A217   204	5460001018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.12014	-118.22935	NEW ROOFTOP SOLAR SYSTEM FOR EXISTING MOTEL. SYSTEM SIZE IS 3.8 KW AC, SCOPE OF WORK INCLUDES (14) LG360 PV MODULES, (14) SEP370 OPTIMIZERS, AND (1) SE3800H INVERTER.PERMIT IS FOR 1 OF 2 PV SYSTEMS, TWO BUILDINGS ON ONE PROPERTY.SECOND SYSTEM UNDER PERMIT#19041-20000-05952	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4039	19041-10000-31580	6735 W FOREST LAWN DR	90068	4	165B185   196	5581028009	C1-1D-RIO	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.14466	-118.33917	Energy plan check for an office T.I located the 1st floor of  a 3-story commercial buiding. Scope includes new lighting and equipment with a total lighting area of 1937-SQ FT.Bld #: 19016-10000-25252	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4040	13041-20000-26813	1111 W WILSHIRE BLVD	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.05259	-118.26348	CONNECT SUB PANEL AND AC AND BATHROOM TO RETAIL SPACE FROM 3000A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4041	17041-10000-16633	5315 S DENKER AVE	90062	8	108B193   472	5003014034	C1-1L	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	33.99368	-118.30472	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 19350 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4042	11041-20000-09181	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4043	19041-20000-25008	15030 W KESWICK ST	91405	6	186B145    20	2209035023	CM-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Issued	06/28/2019 12:00:00 AM	ADDRESS	34.21018	-118.46022	new fire alarm panel to supply new monitoring system 3 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4044	16041-20000-04400	11042 N MT GLEASON AVE	91042	7	210B193   551	2552040035	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.26994	-118.30255	PV1. Install 7.6 kW rooftop-mounted PV system.  (28) SunModule Plus SW-285W modules with (1) SolarEdge SE7600A-US inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4045	15041-10000-34167	827 W AMOROSO PL	90291	11	108B149   630	4241025024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	PIN	33.99332478	-118.45823841	PV1, ROOF MOUNTED SOLAR SYSTEM. (14) MODULES AND (1) INVERTER. TOTAL SIZE 5KW.(14) SUNPOWER DPR-X21-345(1) SMA AMERICA SB5000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4046	14041-20000-23488	25975 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	33.78721	-118.29774	Fire alrm plan check. New fire alarm system for existing Kaiser Permanente medical office. 151 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4047	09041-10001-15708	1925 S CENTURY PARK EAST	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM			PC Info Complete	05/14/2010 12:00:00 AM	ADDRESS	34.06066	-118.41426	Changes from previously approved plans.  Changes are reduce motor pumps (for chiller/water) from 75 HP to 60 HP.  Applicant requesting for electrical plan check.  Plan check for power only.*****INSTALL TWO NEW CHILLER / WATER PUMPS IN THE MOTOR COURT AREA. APPLICANT REQUESTING ELECTRICAL PLAN CHECK.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4048	18041-20001-20145	17340 W DEVONSHIRE ST	91325	12	204B129   179	2734028014	A2-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM			PC Approved	06/20/2018 12:00:00 AM	ADDRESS	34.25733	-118.51256	SUPPLEMENTAL FOR FEE EXPEDITEPLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 15.8KVA SYSTEM CONSISTING OF 3 INVERTERS (SOLIS -1P7.6K-4G-US, SOLIS -1P4.6K-4G-US, SOLIS -1P3.6K-4G-US) WITH 66 MODULES (LONGI GREEN ENERGY TECHNOLOGY CO.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4049	14041-10002-18948	1231 N SAN FERNANDO ROAD	90031	1	144A217   404	5445006907	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.09459	-118.231	New 108 unit apartment and future commercial. Plan check for power and energy. 5 typical units. No methane for applicant. Plan checker to verify fees. Applicant will bring a new set of plans designed for the old 2010 energy code. Fire alarm variance has been filed already.((((((( 5-2-16 M.Z  scope of work is delta 6 feed microwave  from lighting ckt. and a j box prowided on the stove.))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4050	19041-10000-50180	2850 N BENEDICT CANYON DR	90210	5	156B153   162	4382006001	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	02/27/2022 12:00:00 AM	ADDRESS	34.12384	-118.43561	PER AB# 1414 & SB# 1222 $0.00 FEES[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 95 (LG 350N1C-V5) MODULES, 95 (ENPHASE IQ7) MICROINVERTERS,  CONNECTED TO AN EXISTING 600A MAIN SERVICE PANEL. SYSTEM SIZE IS 33.25KW DC & 27.55KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4051	13041-20000-27264	18937 W LABRADOR ST	91324	12	201B121   196	2762040010	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.24914	-118.54641	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.5KW AC USING 30 MODULES. TRANSFORMERLESSINVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4052	16041-20000-23720	200 WORLD WAY Terminal 2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check Title 24 only Dog Relief Areas in Terminal 2 departure level by waiting area next to TSA. Total area: 87 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4053	18041-10000-10933	9722 N TOPANGA CANYON BLVD	91311	12	201B101   352	2746018022	QMR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.24676	-118.60676	REEPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4054	19041-10000-07778	10450 W WILSHIRE BLVD 1-129	90024	5	135B157   257	4326004181	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			03/05/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Issued	03/12/2019 12:00:00 AM	ADDRESS	34.06558	-118.43053	UPGRADING AN EXISTING ELEVATOR SUPERVISOR CONTROL SYSTEM TO A  FIRE ALARM CONTROL SYSTEM. SCOPE INCLUDES  633 NEW FIRE ALARM DEVICES, 40 EXISTING  AND 21 REPLACED DEVICES, 5 POWER SUPPLIES AND 2 CONTROL PANEL (FACP & NODE) FOR A HIGH RISE APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4055	18041-20000-20336	1730 N SAN YSIDRO DR	90210	5	147B157    16	4355003032	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.10298	-118.42426	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 6.4KVA CONSISTING OF 20 PANELS WITH ENPHASE IQ7-96-2-US MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4056	18041-10000-39772	10853 W VANOWEN ST	91605	2	183B173   229	2466018045	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	01/16/2020 12:00:00 AM		Issued	01/16/2020 12:00:00 AM	ADDRESS	34.19413	-118.36777	PLAN CHECK FOR TITLE 24 ONLY FOR - fire damaged repair of entire roof and portion of 2nd floor of existing storage bldg.  Tie in the 2nd foor & roof diaphragm & sub-diaphragms to CMU walls and add new accessible parking. - TOTAL AFFECTED AREA = 5743 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4057	14041-20000-06108	7517 N CORBIN AVE	91306	3	186B117   408	2115017007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.20644	-118.56243	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4058	17041-20000-31574	8800 N CHIMINEAS AVE	91325	12	195B125   688	2769016013	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.23023	-118.52829	PV1.  Install 4.13 kW roof mounted grid tied PV system.  (14) modules with 3.0 kW rated central inverter.   13.5 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4059	14041-20000-01434	672 E INDIANA AVE	90291	11	111B145  1312	4239008019	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	33.99723	-118.46715	PV1 TWO FAMILY DWELLING. PV SYSTEM SPLIT WITH ANOTHER ADDRESS. THIS PLAN CHECK COVERS THIS ADDRESS RANGE. TRANSFORMERLESS INVERTER WITH POWER OPTMIZERS. TOTAL SYSTEM SIZE 3KW AC USING9 MODULES. SYSTEM INTERCONNECTION IS 400A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4060	16041-20000-01603	10940 W STRATHERN ST	91352	2	189B173   228	2409005002	[Q]C2-1L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.21545	-118.3697	Plan check for New Fire alarm system for Residential Care Facility for The Elderly. Total fire alarm device: 32 and 1 fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4061	18041-10000-14676	8040 N VINELAND AVE	91352	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Issued	10/18/2018 12:00:00 AM	ADDRESS	34.21697	-118.37014	PC FOR BANK TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA  4986  SQ.FT REPLACING EXISTING LIGHTS WITH UL LISTED RETROFIT LED KIT. EXISTING EMERGENCY LIGHTS AND SWITCHING TO REMAIN.INDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4062	16041-10001-12055	1315 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			Corrections Issued	04/19/2016 12:00:00 AM	ADDRESS	33.78944	-118.24745	CHANGES TO APPROVED SET OF PLANS. CHANGE TO BREAKER RATING AND CONFIRMATION OF PANEL TYPE. ALL CHANGES NOTED DELTA 2 ON PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4063	14041-10000-06777	14630 W PLUMMER ST	91402	6	198B149    69	2650026900	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.2424	-118.45147	new fire alarm system for a two story fire station.  122 devices and two panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4064	18041-10000-46418	6628 S VERMONT AVE	90044	8	102B197   415	6013009001	C2-1VL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Closed	06/13/2023 12:00:00 AM	ADDRESS	33.97839	-118.29132	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4065	13041-20000-23316	13123 N CRANSTON AVE PV-1	91342	7	222B161    66	2512029074	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.3087	-118.41607	PV-1. One 3.6kW transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4066	16041-10000-44592	10250 W SANTA MONICA BLVD # 1655	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""NYX"" Ste. 1655.  Install new Xrfmr, and  panels, total area 1126 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4067	16041-20002-14225	6570 S WEST BLVD	90043	8	102B185    90	4006020022	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			04/18/2017 12:00:00 AM			PC Approved	04/18/2017 12:00:00 AM	ADDRESS	33.97915	-118.33503	Revisions to approved plan set.  Change to fused disconnect.$0 plan check fee per State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4068	15041-20000-14543	8435 N ORION AVE	91343	6	192B141   304	2654029033	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Apartment			05/13/2015 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.22384	-118.47239	New 24 unit 4 story apartment building. Plan check for power and energy. Adding new lighting including emergency. Total sqft. 19,096	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4069	15041-20000-42433	20860 W DAOSTA WAY	91326	12	213B109   660	2701076013	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM			Reviewed by Supervisor	12/30/2015 12:00:00 AM	ADDRESS	34.2827	-118.58755	PV system. Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP (200A main d/c).System size: 11.4kW. Ungrounded system. Using 400W power optimizers per each module. (42) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4070	17041-10000-44080	4371 N EAGLE ROCK BLVD	90041	14	157-5A219 375	5473026013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.01	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.12399	-118.22146	PC for 14.4kW(AC) PV Enphase Microinverter system mounted on roof of a church. Scope includes 36 modules, (36) IQ6plus microinverters, and a 60A load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4071	17041-10000-38953	11545 N ENCINO AVE	91344	12	213B129   190	2607011009	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.28079	-118.51521	Install new rooftop solar system, 10kW AC (34) modules with optmizers, (1) central inverter	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4072	17041-10000-29817	18205 W RAYEN ST	91325	12	195B125   381	2769013001	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.23194	-118.52974	PC FOR PV SYSTEM RATED 13.1KW AC USING 38 MODULES AC TYPE.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4073	18041-10000-35916	9117 S MAIN ST	90003	8	094-5A203 209	6040035004	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.95317	-118.27403	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4074	13041-10000-18291	4749 N COLLEGE VIEW AVE	90041	14	160-5A219 210	5685001031	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.13348	-118.22103	Roof mounted PV system with 7.595 KW.  Transfomerless inverter and module equiped with power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4075	15041-20000-07175	10000 W PICO BLVD	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.05211	-118.40654	Title 24 plan check only.  Total area = 319 sq. ft. (indoor) + 6,878 sq. ft. (outdoor)Installation of new lighting around clubhouse area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4076	14041-20000-16753	6320 N CANOGA AVE SUITE 1650-E	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.18499	-118.59722	PC FOR TITLE-24 ENERGY ONLY.  EXISTING HIGH RISE BUILDING RELOCATION OF ONE LIGHTING FIXTURE IN FLOOR 1650E.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4077	16041-20000-23278	1902 E MARENGO ST	90033	14	132A223    33	5201016003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.05756	-118.21009	Plan check for Title 24 only. Project site is the second floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,560 sq. ft.Note: Building permit has been pulled under 16016-10000-01938	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4078	19041-10000-49535	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	04/13/2021 12:00:00 AM		Permit Finaled	10/04/2021 12:00:00 AM	ADDRESS	34.16935	-118.53104	TI 1ST FLOOR, INFUSION CLINIC WITH TREATMENT SPACES AND EXAM ROOM PROVIDENCE FOR OSHPD 3. AREA OF SCOPE INCLUDES 2 ADDED PANELS WITH (3000)SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4079	15041-10000-11120	801 S OLIVE ST	90014	14	127-5A209  31	5144019018	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Closed	04/13/2017 12:00:00 AM	ADDRESS	34.04514	-118.25715	TEMP POWER FOR CONSTRUCTION SITE 1600 AMPS.  PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4080	10041-20000-13922	17938 W BURBANK BLVD 38  R-2	91316	12	174B129   872	2159005026	R3-1	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	34.17207	-118.52292	PLAN CHECK T-24 ENERGY FOR INSTALLING NEW LIGHTING TO PORTION OF FIRE DAMAGED  CARPORT. LIGHTING FIXTURES IN THE  NON FIRE DAMAGED PORTION ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4081	11041-10006-03572	340 S MAIN ST	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM			PC Approved	10/21/2011 12:00:00 AM	ADDRESS	33.99519	-118.47673	Modification to an approved set of plans.  Adding new emergency lighting for the outdoor space.  The new emergency light are equiped with 90-min battery back up and connected to the existing branch circuits.  Also added a 750 VA interser being fed from an existing panel for the emergency lighting.  Two offices (A102 and A103) have gone from regular office to medical offices.  <<<<<<<<<<<<Tenant improvements to all three floor including new exterior and interior openings, new restrooms, caf� and kitchen, new offices, pantries, and conference rooms.>>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4082	13041-10000-13874	401 S VERMONT AVE #1 , #2	90020	10	135B197   497	5502009020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.21	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.06699	-118.29189	13041-10000-13874.EXISTING 2 TENANT SPACE RESTAURANT AND RETAIL COMBINE TO 1 RESTAURANT (PARTIAL CHANGE OF USE) NEW PARTITION WALL; COSMETIC DECORATION WORKS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4083	12041-10000-30258	10250 W SANTA MONICA BLVD # 133	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Approved	01/29/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	12041-10000-30258TENANT IMPROVEMENT IN EXISTING RETAIL STORE AT THE CENTURY CITY MALLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4084	10041-10000-18747	2001 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	12/10/2010 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	PIN	34.06587468	-118.19737837	140 devices and two panels for a commercial bldg. three stories.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4085	18041-10000-20340	6505 S ESPLANADE	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	09/23/2021 12:00:00 AM	ADDRESS	33.96159	-118.45071	PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW LOAD CENTER, 6  MODULES(#SC325) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 1.95KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4086	14041-10000-24222	2405 S VERMONT AVE	90007	8	123B197   589	5054026031	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM			Not Ready to Issue	09/22/2014 12:00:00 AM	ADDRESS	34.03426	-118.29179	PC FOR T24 ONLY. Change of use from retail to restaurant and tenant improvement, and new rooftop mechanical equipment. UNDER CODE 2008. Permit pulled under 14041-10000-25909TOTAL AREA 1500 SQ FTB# 14041-10000-10916	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4087	13041-10000-30454	13202 S ESTRELLA AVE	90248		078B201    24	6132003015							Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	33.91311	-118.28575	TITLE-24, PART 6 ENERGY WORK; REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. TOTAL AREA IS 13500 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4088	13041-10001-09832	18555 W VENTURA BLVD	91356	3	174B125   543	2160007012	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.1697	-118.53779	"plan check only - CHANGES TO APPROVED SET: LAYOUT STRUCTURE CHANGED.Feeder sizes updated. ""This building is designed as a Core and Shell Building only; separate building, electrical and mechanical permits are required for all future residential unit build-outs or commercial tenant space build-outs."" Original description: New panels, circuits, and lighting for an existing Medical Clinic.  Full Plan Check."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4089	14041-10000-13199	1158 N KENMORE AVE	90029	13	144B197   462	5540027007	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.09259	-118.29726	PV1, INSTALL 4.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN PANEL.STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4090	12041-10000-01749	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	2951.01	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	07/05/2013 12:00:00 AM	ADDRESS	33.77884	-118.29327	New methane gas mitigation system at Conoco Phillips gas refinery in a classified area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4091	19041-10000-27760	8635 S KITTYHAWK AVE	90045	11	096B169   626	4123004009	[Q]C2-1VL-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	06/23/2020 12:00:00 AM		Permit Finaled	11/03/2020 12:00:00 AM	ADDRESS	33.95903	-118.3906	TI for an exisitng commercial space, scope of work includes new lighting and control. Total affected area is 9000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4092	13041-20001-25939	23545 W WINDOM ST PV1	91304	12	186B093   325	2027036009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.20575	-118.64082	INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 7.85 KW (plan check for original permit issuance)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4093	14041-10004-29996	616 S NORMANDIE AVE	90005	10	135B197  1114	5502031011	R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			03/21/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	34.06287	-118.30017	03/21/16Changes to an approved set of plans. All changes are made under delta 3. Changes to reflect what is on the field. Changes include relocating load equipment on panel 'EF,' and adding emergency panel 'EA'to reflect on the field. NOTE: PERMIT PULLED UNDER PCIS#14041-10000-29996((((Improvements to 16 story senior living apartment building.  Plan check for the addition of generator for fire pump and new lighting and power for redesigned 1st floor. Renovations to lighting for common area corridors above first floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4094	15041-20000-27948	10250 W CONSTELLATION BLVD #1020	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check Title 24 only for existing office in high-rise T.I. Total indoor area: 1,294 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4095	13041-20000-09844	2021 W PICO BLVD	90006	1	129A201   201	5136023030	C2-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.04709	-118.28194	New service, panels, loads, lighting for an existing Retail store.  Load is greater than 400 amps.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4096	11041-10000-11566	681 S BONNIE BRAE ST	90057	1	132A203   154	5142002904	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.05601	-118.2743	NEW STAND-ALONE FIRE ALARM SYSTEM IN EXISTING 6-STORY MIXED USE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4097	10041-20001-17894	11723 N FENTON AVE	91342	7	213B165   170	2531009041	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1041.03	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM			PC Approved	12/02/2010 12:00:00 AM	ADDRESS	34.28324	-118.39296	Plan check only. Revision to approved plans for outdoor lighting.  No sign to be installed under this permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4098	13041-20000-03686	12181 W BLUFF CREEK DR	90094	11	102B161  1150	4211010099	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	33.97788	-118.40638	Change to lighting in an exisiting corridor in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4099	14041-10001-31121	6431 W 85TH PL	90045	11	096B165   408	4108020001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	33.9606	-118.40012	((1/16/2015- ADDING 7 MODULES TO SYSTEM))Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4100	10041-20000-14859	4811 N ANDASOL AVE	91316	5	168B129   418	2290006030	RA-1	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	11/17/2010 12:00:00 AM	ADDRESS	34.15737	-118.51205	pv system for single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4101	17041-10000-40499	939 E 119TH ST	90059	15	084B209   660	6084022008	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	ADDRESS	33.92466	-118.25721	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 3.0 KWAC /3.0KWDCSCOPE INCLUDES 10MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4102	16041-20000-07231	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Closed	07/18/2018 12:00:00 AM	ADDRESS	34.04538	-118.26389	TEMPORARY POWER ONLY PLANCHECK. 1000 AMP 120/240 SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4103	13041-20001-32100			12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	PIN	34.2365815	-118.56509594	((Expedite fees))PV2 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 993.6KWAC. 4030 MODULES AND 36 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4104	17041-10001-19953	7270 W MELROSE AVE	90046	5	141B181   622	5525013004	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM			PC Approved	12/22/2017 12:00:00 AM	ADDRESS	34.08338	-118.34821	SUPP. FOR A LOST SET OF PLAN. THIS IS PLAN CHECK ONLY. PERMIT PAID UNDER MASTER. PC FOR TITLE 24 ENERGY ONLY FOR TI (N) PHOTO STUDIOINSTALLING NEW LIGHTS AND NEW RECEPTACLES. TOTAL AFFECTED AREA 2510 SQ.FTBL# 17016-10000-13241	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4105	16041-20000-43142	4738 N TOBIAS AVE	91403	4	169-5A151 233	2265007033	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.15717	-118.45185	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4106	19041-10000-20539	2200 E TROJAN WAY	90033	14	135A225   142	5202001009	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	04/28/2021 12:00:00 AM	ADDRESS	34.06447	-118.20225	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 5 & 6. CHANGES INCLUDE ADDING NEW CIRCUITS, REVISING PANEL SCHEDULES, REVISING LOAD CACLULATIONS, ADDING A NEW 100KW GENERATOR, ATSs, and revising floor plans. NOTE: MASTER APPLICATION IS UNDER 19041-10000-01213	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4107	16041-20001-26350	1056 S ALVIRA ST	90035	5	132B173   675	5087013009	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.05725	-118.37096	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system.(35) 290W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4108	19041-30000-22655	11050 W HARTSOOK ST	91601	2	171B173   783	2353007053	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	34.1638	-118.3723	Plan check for a fire alarm system for a 3-story, 48-unit apartment building. Fire alarm system consists of (1) FACP and (86) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4109	14041-10000-11119	5806 W HAROLD WAY	90028	13	147A191    22	5545011012	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.0991	-118.3161	NEW FIRE ALARM SYSTEM FOR APARTMENT BUILDING. 170 DEVICES AND 1 FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4110	15041-10000-11050	19819 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.85048	-118.28771	REPLACE 6 HID FIXTURES  WITH LED FIXTURES.  TITLE 24 PC FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4111	14041-10000-07769	5850 S 3RD AVE	90043	8	105B189    90	4005022013	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Expired	04/18/2016 12:00:00 AM	ADDRESS	33.98766	-118.32045	PV1, INSTALL 3 KW DC ROOF-MOUNTED STANDARD PLAN SOLAR ARRAY ON A SINGLE STORY HOME. (1) TRANSFORMERLESS INVERTER:  POWER-ONE AURORA PV1-OUTD-S-US-Z-A(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4112	10041-10000-06180	5333 W ZOO DR TOUCAN-DATA KEEP	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	9800.09	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.14867	-118.28623	PLAN CHECK POWER AND ENERGY FOR TOUCAN BUILDING #0810-10000-02154 AND DATAKEEPER BUILDING #08010-10000-02152	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4113	10041-20000-15973	11444 W OLYMPIC BLVD 5TH &11TH-FLOOR	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	ADDRESS	34.03654	-118.44363	TI IN EXISTING OFFICE AREAS ON 5TH AND 11TH FLOORS TENANT SPACES. PLA N CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4114	14041-20001-14279	13629 W HARTLAND ST	91405	2	183B157   834	2328012045	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			Reviewed by Supervisor	06/10/2014 12:00:00 AM	ADDRESS	34.195	-118.42984	Expedited plan check per applicant request.  (((PV1.  Install 11.25 kW roof-mounted utility-interactive PV system.  Transformerless inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4115	12041-10000-16781	10828 W MOORPARK ST	91602	4	165B173   366	2423015001	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.15023	-118.36656	New 800Amp service, new panels, a transfer switch, lighting, and circuits to an existing 16,625 sq ft church.  Full Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4116	14041-10003-19839	500 WORLD WAY 4thFloor	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	33.94248	-118.40461	02/09/2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 6. CHANGES INCLUDE CHANGE OF FIXTURES. ((((6/2/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE MODIFICATION IN LIGHTING FIXTURE TYPES AND ADDING NEW LOADS TO EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY. DELTA 5 INDICATES ALL THE CHANGES. ))Changes to approved set.  Full plan check revised by adding one 24KW water heater and  one 70-Amp  panel.  All changes clouded and marked with delta-4 only.*****Previous Work Description*****plan check for power and energy. 4th floor. Delta airline Terminal 5 SKYCLUB Renovations. Changes include clarifications on T24 and 100% rated breakers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4117	17041-20000-26308	2300 N ALTO OAK DR	90068	4	153B193   438	5587008042	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.11179	-118.31337	Plan check for the addition of (2) Tesla PowerWalls to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4118	13041-10000-33075	5649 N IRVINE AVE	91601	2	174B169   659	2339015033	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Expired	02/02/2016 12:00:00 AM	ADDRESS	34.17349	-118.38567	PV1.  Install 1.5 kW roof-mounted PV system, interconnect with main service panel.  6 modules: Yingli YL250P-29b.  Transformerless inverter: Power-One Aurora PVI-3.0-OUTD-S-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4119	18041-10000-13982	343 N BROAD AVE	90744	15	030B205  1327	7418024017	[Q]CM-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Issued	04/17/2018 12:00:00 AM	ADDRESS	33.77388	-118.26086	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4120	14041-20001-04973	5347 N HINTON AVE	91367	3	171B093   123	2044012005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.16786	-118.63771	(((expedite fees))))pv1 single family dwelling. total system size 10kw ac using transformerless inverters nonstnadard plan. using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4121	15041-20000-37663	15127 W PLUMMER ST	91343	7	198B145    13	2656008014	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.24288	-118.46202	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 16.125KWac. (75)MODULES-HANWHA Q CELLS Q.PRO-G3 265W (75)MICROINVERTERS-ENPHASE ENERGY M215-60-S2X(1)100A SUBPANELPermit Fees $0 per California State Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4122	17041-30000-46207	1734 W COLORADO BLVD	90041	14	162A225   115	5689003033	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	05/18/2020 12:00:00 AM	ADDRESS	34.13918	-118.20493	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,955 sq. ft.Note: Building application has been generated under 17016-30000-24630	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4123	12041-10000-13863	932 S PARK VIEW ST	90006	1	130-5A201  13	5136004011	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	34.05389	-118.28242	New fire alarm system for a new child care area comverted from a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4124	12041-20000-31006	6476 N ELLENVIEW AVE	91307	12	180B089   741	2032024005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2012 12:00:00 AM			PC Info Complete	02/12/2013 12:00:00 AM	ADDRESS	34.18778	-118.65704	PV-1. Plan check for single family dwelling. Three strings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4125	17041-10000-41045	657 S AVENUE 60	90042	14	150A233   160	5312025018	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.10485	-118.1809	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER. (13) MODULES AND (1) INVERTER. TOTAL SYSTEM SIZE IS 3.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4126	14041-10000-16501	5235 N BILOXI AVE	91601	4	171B177   479	2417017016	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Expired	09/02/2016 12:00:00 AM	ADDRESS	34.16592	-118.3584	PV1, INSTALL 7.14 KW DC SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS.(28) MODULES: TRINA SOLAR # TSM-250PA05.18(2) TRANSFORMERLESS INVERTER: AURORA PV1-3.6-OUTD-S-US-Z-A  AND AURORA PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4127	14041-10001-35966	755 N LAUREL AVE	90046	5	141B177   294	5528007025	R1-1	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM			PC Approved	04/30/2015 12:00:00 AM	ADDRESS	34.0853	-118.36495	$0 submittal fee is due to state senate bill sb-1222. Modification to approved set.  Minor revisions to plan notes and inclusion of racking and attachment cutsheets.  (((PV1 5.0kw roof mounted system with (1) solaredge SE5000A inverter, (18) LG Electronic LG305N1C modules and Solaredge power optimizers.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4128	15041-10000-28852	4411 N NATOMA AVE	91364	3	166-5A111  79	2174010004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.15035	-118.58009	PV 1 pc at counter for a residential site. Roof mounted solar system. Scope: Microinverter 5 kw total system size, (20) modules. (1) 100 amp load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4129	13041-10000-06391	9301 N TAMPA AVE T61	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	renovation of retail space for victorias secret. pc for t24 only. permit to be issued by pc staff. total area 4300 sq ft. tenant space 61	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4130	16041-10001-31930	10250 W SANTA MONICA BLVD # 1710	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set under Delta-6 only:1.  E1.0 updated receptacle locations per architectural change2.  E2.0 updated lighting near storefront per architectural change3.  E5.0 Added ckt A-17 to panel A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4131	13041-10001-24668	19223 W PRAIRIE ST	91324	12	198B117   141	2762022013	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.23922	-118.55244	10-16-13, No of Moudules, invereter strings and other calculations changed refrence to original submital.PV1 ROOF MOUNTED SOLAR INSTALLATION.  SYSTEM SIZE IS 8.085 KW DC AND 6.6 KW AC. [INVERTER: POWER-ONE # AURORA PVI-3.6-OUTD-S-US AND POWER-ONE # AURORA PVI-3.0-OUTD-S-US |||| MODULES: TRINA SOLAR # TSM-245PC05/PA05.18]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4132	13041-10001-32033	12022 W RIALTO ST	91352	6	192B165   295	2633011005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			Verifications in Progress	01/31/2014 12:00:00 AM	ADDRESS	34.22421	-118.39429	][][EXPEDITED PER APPLICANT REQUEST ][][]PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING WITH (E) 125A  MAIN. SYSTEM SIZE IS 3 kW DC WITH (12) MODULES RENESOLA JC250M-24/BB IN 1 STRING, AND (1) SOLAR EDGE INVERTER SB3800A-US WITH OPTIMIZERS OP250-LV ON NON-STANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4133	18041-10000-20605	725 S FIGUEROA ST #4130	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR ENERGY ONLY, TENANT IMPROVEMENT AT SPACE # 4130 OF ( E ) HIGHRISE BUILDING : SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2010.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4134	16041-20000-08651	2240 N LAKE VIEW AVE	90039	13	147A209   243	5440019026	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.09663	-118.25425	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system. One 300W power optimizer per module.(14) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4135	15041-20000-30175	18100 W CHATSWORTH ST SUITE C	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.26437	-118.52699	Plan check for energy only. TI to nail salon. New general lighting (emergency lighting existing to remain). 1,450sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4136	18041-10000-03795	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	PIN	34.0586034	-118.41904766	Revision to approved set of plans noted as Delta 36 : new feeder/ 100A panel for for storage LL710 PLAN CHECK ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4137	18041-10000-36246	601 W 5TH ST #400	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.05049	-118.25386	PLAN CHECK FOR TITLE 24 ONLY FOR - [1] REMOVE THE STORAGE IN THE BACK .[2] REPLACE CONFERENCE ROOM BY AN OFFICE LIBRARY.SUPPLEMENTAL PERMIT TO  PCIS # 18016-10000-16580. - TOTAL AFFECTED AREA = 6482 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4138	19041-10000-07456	1999 S BUNDY DR SUITE-3-26	90025	11	123B149   406	4259019007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.03406	-118.45593	T-24 ONLY FOR A TI  IN AND EXISTING OFFICE BUILDING SUITE 3-26. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECETD AREA IS 2956 SQ.FT B# 19016-30000-02838	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4139	12041-10001-01993	2669 N GRIFFIN AVE	90031	1	139-5A223  23	5206005018	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			09/21/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Expired	12/08/2014 12:00:00 AM	ADDRESS	34.07847	-118.21203	PLAN CHECK FOR DELTA 1 REVISION TO APPROVED PLANS. ADD NEW 125KVA TRANSFORMER AND CHANGE INVERTERS TO PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4140	16041-20000-40975	10261 ANGEL LANE	91331	7	204B165   440	2537004050	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25708805	-118.40496952	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4141	15041-20000-28599	148 S BRISTOL AVE	90049	11	132B137   542	4405021010	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.05557	-118.48785	Adding new 600A service to single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4142	15041-20001-34861	21215 W BURBANK BLVD 4th Floor	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	34.17353	-118.59268	Changes made to approved set.  Relocation of remodeled areas in scope of work of existing 4th floor office.  Plan check for energy.  (((Plan check for energy only. Interior remodel to existing office on the 4th floor. New lighting (incl. emergency) and receptacles.  7,038sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4143	13041-10001-31565	9000 N SUNLAND BLVD	91352	7	195B173   151	2544026032	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Info Complete	06/16/2017 12:00:00 AM	ADDRESS	34.23264	-118.36658	PC FOR CHANGES TO APPROVED SET OF PLANS AND TO SEPARATE PARKING LOT ON OWN ELECTRICAL PERMIT. CHANGES TO FLOOR PLANS. UPDATED PANEL SCHEDULE AND ADDED NEW PANEL. CHARGING PERMIT FOR CORRECT SERVICE SIZE, RATED 800A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4144	18041-10000-11938	3535 E 14TH ST	90023	14	118-5A225 344	5191021015	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.01741	-118.20173	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4145	12041-20000-07184	2121 S AVENUE OF THE STARS STE 160	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	TI for Fox Plaza. 2121 Avenue of the stars. Plan check for energy and emergency lighting. Commercial High-rise. 1860 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4146	12041-10001-07516	7833 W SUNSET BLVD	90046	4	147B177   967	5551020019	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.09823	-118.36022	CHANGE OF USE FROM RETAIL TO BANK;   Title 24 approval is on 12041-10000-07516;plan chk is for power	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4147	16041-10000-43667	22841 S LOCKNESS AVE	90501	15	045B193   441	7347017063	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	08/14/2018 12:00:00 AM		Issued	08/14/2018 12:00:00 AM	ADDRESS	33.81796	-118.30716	PC for power only. Instaling new service rated at 400 Amps 120/240V 3phase 4Wire. Existing storage under Hazardous area. New load equipment and emergency generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4148	11041-10000-05091	4848 W JEFFERSON BLVD	90016	10	120B181   805	5046011004	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM			PC Approved	03/15/2011 12:00:00 AM	ADDRESS	34.02539	-118.35009	TI in an industrial space. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4149	14041-10002-19956	5530 E VALLEY BLVD	90032	14	138A237    30	5221013038	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	ADDRESS	34.07423	-118.16225	CHANGES TO AN APPROVED SET OF PLANS.  REARRANGE ORIENTAION OF SWITCHGEAR.  CHANGES NOTED DELTA A.  THIS IS PLAN CHECK ONLY.  PC FOR POWER AND ENERGY. NEW 7 ELEVEN WITH A RETAIL STORE 14010-10000-02403:DISPENSERS AND CANOPY UNDER APPLICATION 14041-10000-32528ESTIMATION OF THE # OF DEVICES PER APPLICANT REQUEST AND ADDING THE MISSING PANELS DUE TO UNSHOWN PANEL SCHDEULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4150	11041-10000-21030	737 W WASHINGTON BLVD	90291	11	105B149   131	4229010037	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	PIN	33.98746957	-118.4539013	New 381sq. ft. addtion for exercise room at Best Western Hotel.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4151	17041-20001-17575	19140 W CHARLES ST	91356	3	168B121   221	2176031007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.15742	-118.55044	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 11.6 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4152	13041-10000-02394	5946 W 76TH ST	90045	11	102B169   464	4105004015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2013 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	33.97205	-118.38757	PHOTOVOLTAIC SYSTEM FOR A SINGLE FAMILY SINGLE STORY DWELLING. TOTAL SIZE 2.16KW, USING 10 MODULES. PANEL - REC 245 PE. MICROINVERTER ENPHASE M215-60-2LL-S22.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4153	16041-20001-17172	11428 W SHERMAN WAY	91605	2	183B169   683	2320001022	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	34.20103	-118.37983	[[[7/6/17 CHANGES TO APPROVED SET. ADDING WIRING AND CONTROL DETAILS FOR THE REFRIGERATION SYSTEM]]]CHANGE OF USE FROM WAREHOUSE/OFFICE TO RETAIL. NEW COSTCO. NEW ELECTRICAL SYSTEM. FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES ONE NEW 5000A 480/277V 3 PHASE 4 WIRE SERVICE, NEW DISTRIBUTION  PANELS, CIRCUITS AND LIGHTING. PERFORMANCE METHOD IS BEING USED. TOTAL AFFECTED AREA IS 616833 SQ. FT. Building application ref no.: 16016-10000-09606	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4154	17041-20000-44133	1999 S AVENUE OF THE STARS Ste 2045	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	Tenant improvement of (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4155	18041-10000-44450	2300 W PICO BLVD	90006	1	129A201   247	5056004024	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.04707	-118.28662	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4156	15041-20001-19686	12630 W RAYMER ST	91605	2	186B161   566	2324003048	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM			PC Approved	07/07/2015 12:00:00 AM	ADDRESS	34.20343	-118.40847	"07/07/2015 Changes to an approved set of plans. All ""B"" fixtures have been replaced by ""A"" fixtures. *****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,550 sq. ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4157	14041-10000-04432	1458 S SAN PEDRO ST #L-57	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in commercial retail space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4158	18041-20000-22816	4095 S GLENCOE AVE	90292	11	108B153  1121	4230005046	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	01/18/2019 12:00:00 AM		Issued	01/18/2019 12:00:00 AM	ADDRESS	33.98972	-118.44276	Plan check for a PV2 roof-mounted PV system. System size is 72 kWdc/65 kWac and consists of (2) 28 kWac rated inverters, (180) modules, (1) load center, and (1) transformer.Permit Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4159	18041-10000-05066	2365 E CENTURY BLVD	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	33.94668	-118.2305	"PC FOR POWER ONLY, NEW (1) ONE STORY RETAIL ""SHELL"" BUILDING-SHOPS 3. SCOPE OF WORK INCLUDES NEW SERVICE  1200AMP, 208/120V, T-24 WILL BE UNDER A SEPARATE APPLICATION. (JORDAN DOWNS PHASE 1C)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4160	15041-20000-03855	8030 N BELLINGHAM AVE	91605	2	189B165   336	2309022016	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2015 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Expired	03/06/2017 12:00:00 AM	ADDRESS	34.21665	-118.39861	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. TOTAL OF 21 MODULES. ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4161	15041-20000-42541	17707 W RINALDI ST	91344	12	213B129   428	2601040031	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.27958	-118.51964	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4162	14041-20000-27235	3319 S STEWART AVE	90066	11	114B153    87	4247022016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.01233	-118.44529	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.5KW INTERCONNECTED WITH MSP.(14) SOLAR WORLD 280W MODULES(14) ENPHASE M250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4163	14041-10000-17366	12526 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	33.97833	-118.41207	PC FOR METHANE MITIGATION. NEW Type VA  6-unit  4-story  APARTMENT BUILDING with attached parking.   1 PANEL AND 27  DEVICES.BUILDING APP # 14010-10000-01299	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4164	16041-10000-16755	8250 N WOODMAN AVE	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.22107	-118.43251	$0 permit fee due to senate bill 1222 from 2012Installation of new roof mounted solar PV array on existing Kaiser Foundation medical office building.  Total system size = 317 kWac.  11 SCA23KTL inverters, 1 SCA28KTL inverter, and 1 SCA36KTL inverter.  1,240 Hyundai HIS-S325TI modules.  Supply side tap used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4165	12041-10000-19275	23903 S NORMANDIE AVE	90710	15	042B197   226	7438017***	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Issued	10/22/2012 12:00:00 AM	ADDRESS	33.80859	-118.2989	Plan check for new switchboard supplying new microturbines. Existing electrical system. Installation in hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4166	18041-10000-06421	300 N VIA NICOLAS	90272	11	126B117   124	4416002015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.044	-118.55426	PV1, New roof mounted solar system using AC modules. (56) modules and (1) load center. Total system size is 19.32KWDC and 17.9KWAC.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4167	18041-10001-09291	100 W WORLD WAY T162	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	08/15/2018 12:00:00 AM	PIN	33.94684048	-118.40128468	"PC FOR CHANGES TO APPROVED SET MARKED UNDER DELTA 2. THIS IS PLAN CHECK ONLY!SCOPE INCLUDES CHAGES TO FIXTURE TYPE AND ELECTRICAL RATING WITH REVISIONS TO T24.PLAN CHECK FOR T24 ONLY, TI  TO RETAIL CONCESSION AT LAX; SPACE T162 OF 642 SQ FT  ON THE CONCOURSE LEVEL 3 OF TERMINAL 1. INSTALL (1) 225A PANEL AND ITS CIRCUITRY FROM (E) DIST. BOARD ""2LDSA"", TOTAL AREA: 642 SQ.FTB# 18016-10000-07682"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4168	19041-20000-01138	2736 W DICTURN ST	90065	14	157-5A219 179	5473019013	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.12616	-118.22592	install (2) tesla batteries 5KWh to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4169	10041-10000-10683	2140 E 7TH PL # A1N	90021	14	124-5A217 350	5166003006	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM	06/07/2010 12:00:00 AM		Permit Finaled	07/06/2010 12:00:00 AM	ADDRESS	34.03337	-118.22846	Ti in a commercial building. Plan check for energy and T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4170	19041-20000-32857	10327 N SAMOA AVE	91042	7	204B197   706	2565008093	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.25675	-118.28709	PV1.  Install 6.528 kW AC roof mounted grid tied PV system.  (24) modules with 7.6 kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4171	15041-10000-35994	1755 W 39TH PL	90062	8	117B193  1479	5035018017	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.01383	-118.3129	PV1 ROOF MOUNTED SYSTEM, TOTAL SIZE 5.83 KW. (22) MODULES AND (1) 5KW INVERTER. (22) KYOCERA #KU2656ZPA(1)ABB #PV1-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4172	16041-20001-23084	13213 N MIRA MAR DR	91342	7	225B165    19	2580018***	RD6-1XL	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.31289	-118.40476	Expedite per applicant request{{{{Plan check for PV roof mounted system. System size: 6.0kW with 18 modules and 1 inverter(6.0kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4173	14041-20001-24795	7000 S HOOVER ST Unit #2	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	expedite feesNew roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #2.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4174	19041-10000-06643	6080 W CENTER DR 100-150	90045	11	102B169   954	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	Energy plan check for an office T.I. Scopes inlcude new lighting and equipment with total area of 2900-SQ FT located in a high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4175	19041-10000-20694	7251 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	09/17/2020 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	33.94287	-118.42108	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW EQUIPMENT IN AN OUTDOOR FUELING LOT AT LAX. HAZARDOUS CLASS 1 DIV 1, CLASS 1 DIV 2 LOCATION. NEW BACK UP GENERATOR, ATS, FUELING DIESEL DISPENSERS BEING ADDED. EXISTING ELECTRIC VEHICLE CHARGERS HAVE BEEN RECONNECTED TO BALANCE LOAD. EV CHARGERS 15-18 ARE NEW.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
4176	19041-20000-35993	4652 N WORTSER AVE	91423	4	168B161   660	2362003002	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.15553	-118.4169	PV1.  Install 8.19 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (26) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4177	17041-10002-23919	3201 S HOOVER ST 8A-1	90007	9	121-5A201 201	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Approved	06/15/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	Full plan check for a lost of plan. New circuits and outdoor lighting are also added. All fee will be paid under original application number, 17041-10000-23919.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4178	19041-10000-33218	800 W 6TH ST 4TH FLOOR	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Issued	09/11/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	ENERGY PC ONLY FOR PROPOSED RESTROOM AND ELEVATOR LOBBY REMODEL ON 4TH FLOOR OF OFFICE BUILDING TO ENLARGE RESTROOMS. AREA 965SFBUILDING PERMIT # : 19016-10000-19038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4179	18041-10001-26206	5533 S EA WAY	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM			PC Approved	12/06/2019 12:00:00 AM	ADDRESS	33.97374	-118.42896	CHANGES TO THE PERMITTED SET OF PLANS- REVISED THE SERVICE EQUIPMENT LINE-UP TO SHOW MAIN SWBD, FP TAP AND MAIN SBD CHANGES IN THE LINE UP- DELTA 9 ONLY; ALSO REINSTATING THE EGC FOR SBHP-1A AS 750 KCMIL AL CONDUCTOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4180	17041-20000-38955	17614 W POSETANO ROAD	90272	11	126B117   525	4416012020	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.04078	-118.56043	New 13.5 kWh battery back-up system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4181	13041-10000-30052	1201 N LAS PALMAS AVE	90038	4	144B185  1344	5532004037	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.09272	-118.33648	PV1, Install 1.59m kW DC roof-mounted photovoltaic system, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US. 6 modules Suniva OPT265-60-4-1B0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4182	14041-10000-03803	2675 E OLYMPIC BLVD	90023	14	120A221    22	5170016039	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.02459	-118.22015	Tenant improvement to existing Burger King for new Starbucks.  Newly connected load below 400A, title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4183	18041-20000-22980	13181 W MINDANAO WAY	90292	11	105B153   104	4212004007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM			PC Approved	06/20/2018 12:00:00 AM	ADDRESS	33.98449	-118.43785	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,043 sq. ft.Note: Building application has been generated under 17016-10000-03999	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4184	14041-20000-15463	8629 S SEPULVEDA BLVD	90045	11	096B165   693	4122001012	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.95874	-118.39651	In new outdoor lighting for Hometown Buffet.  Plan for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4185	19041-10001-32551	10250 W SANTA MONICA BLVD 1280	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			PC Approved	10/18/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Changes to an approved set of plans. All changes are clouded. Changes include replacing panelboard ""CA"" for a split bus panelboard, relocating circuits on the floor plans. Note: Permit Fees are paid under master application 19041-10000-32551"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4186	19041-10000-19985	5901 W CENTURY BLVD 1550	90045	11	090B169    15	4124030042	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE. TOTAL EFFECTED AREA 1381 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4187	19041-10000-50043	5044 N BELLAIRE AVE	91607	2	171B161   885	2357009007	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.16251	-118.40927	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 32 MODULES(LG365), 32 OPTIMIZERS (P370) AND 1 CENTRAL INVERTER (SE10000H-US). SYSTEM SIZE IS 11.68KWdc AND 10KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4188	09041-10001-20083	1521 W PICO BLVD 1-56	90015	1	127-5A203 102	5137032023	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Apartment			11/23/2010 12:00:00 AM			PC Approved	11/23/2010 12:00:00 AM	ADDRESS	34.04432	-118.27583	Installation of ENT instead of EMT IN THE CONCRETE DECK FOR SUBFEEDERS TO THE SENIORS UNITS. CHANGES ARE SHOWN/BUBBLED ON THE SINGLE LINE DIAGRAMNew 56 unit, 100% affordable, mixed-use building with one level of underground parking.  Power and emergy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4189	13041-10000-26297	11343 N ORCAS AVE	91342	7	210B173    39	2529022006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.27585	-118.3684	PV1 ROOF-MOUNTED PHOTOVOLTAIC SYSTEM. TRANSFORMERLESS SYSTEM,; SYSTEM SIZE IS 6.5KW DC WITH (26) MODULES: TRINA #TSM-250PA05.18(1)SOLAREDGE SE6000A AND SOLAREDGE POWERBOX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4190	13041-20000-26583	2162 W SUNSET BLVD	90026	13	139-5A207  96	5402030004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	ADDRESS	34.07749	-118.26582	T24 FOR T.I. CONVERT RETAIL SPACE TO VETERINARY CLINIC. TOTAL NEW CONNECTED LOAD LESS THAN 400A. TOTAL SQRFT 3080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4191	19041-30000-23654	678 S ARDMORE AVE	90005	10	132B193   179	5094001002	R5-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Apartment			06/20/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/28/2021 12:00:00 AM	ADDRESS	34.06063	-118.30186	PC FOR Fire Alarm system for a commercial building, Scope includes 1 FACP AND 410 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4192	16041-10000-17243	10402-10402 1/2 S MAIN ST	90003	8	090A205   103	6063017002	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.10	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Expired	06/19/2018 12:00:00 AM	ADDRESS	33.94173	-118.2737	PV1, INSTALL 2.385 KW DC / 3.0KW AC ROOF-MOUNTED SOLAR ARRAY ON A 2 STORY DUPLEX.(9) MODULES: KYOCERA KU2656ZPA(1) ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4193	17041-10000-14095	17240 W SATICOY ST	91406	6	186B133   239	2203017044	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.20827	-118.50863	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 1200 SQ. FT. TOTAL OF 6 FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4194	16041-20000-11048	802 S MATEO ST	90021	14	124-5A217 334	5166014011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.03338	-118.23212	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 400 sq. ft. Note: Building application has been created under 16016-10000-00945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4195	11041-20000-19873	1801 S CENTURY PARK EAST s.700	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.06201	-118.41537	s.700 office t.i. Energy onlyFire  alarm system is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4196	17041-10000-00097	8408 W HILLSIDE AVE	90069	4	148-5A173 480	5558028027	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM			PC Info Complete	02/28/2017 12:00:00 AM	ADDRESS	34.09935	-118.3728	PC FOR POWER. NEW 2-STORY SINGLE FAMILY DWELLING WITH 1-LEVEL BASEMENT, ROOF DECK AND ATTACHED 2-CAR GARAGE. SCOPE INCLUDES A NEW 1600A 120/208VSERVICE 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND ONE NEW 75KW GENERATOR. B#15010-10000-04573	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4197	16041-10003-45568	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.06047	-118.29555	DELTA 6 REVISIONS TO PERMITTED SET OF PLANS; REFEED PANEL LBa FROM DIST BD DP-B; REVISE BRABCH CIRCUIT LOADS FOR THE EV CHARGERS; REVISED LOAD CALCULATIONS FOR SWBD MSA; UPDATE VD CALCULATIONS AND FEEDERS SIZES; ADDED LUMINAIRES FOR HARDSCAPE LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4198	13041-20000-33865	19541 W BLACKHAWK ST	91326	12	204B117   137	2708004014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.2579	-118.55952	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.0KWAC. 22 MODULES AND 1 INVERTER. SUBMITTED PER APPLICANT REQUEST.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4199	17041-20000-35804	11142 N CHRISTY AVE	91342	7	210B177   256	2528029027	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Expired	03/24/2024 12:00:00 AM	ADDRESS	34.27206	-118.35904	pv1install roof mounted pv system sized 3.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4200	14041-20001-17116	10526 W DUBNOFF WAY BLDG A	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.18656	-118.36106	"06-23-16. Changes to an approved set of plan. Changes include addition of FACP and 7 water heaters in each restroom and new circuits for receptacles and gate motor. Changes apply to delta 1, 2, and 3 {{{{{T.I. for classrooms of Building A.  Install branch circuits and lighting.  Plan check for power and energy.Note: Applicant will submit approved plans within 3 days.  See ""Application Comment"" for more info.}}}}}}}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4201	19041-10000-50112	3321 S BARBYDELL DR	90064	5	123B165   719	4316024017	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.03261	-118.40382	NEW ROOFTOP SOLAR INSTALLATION 10.79KWdc (10.40KWac) (9.75KW CEC) USING 33 SP E20-327 AC MODULES. CONNECTED TO A NEW 225Amp SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4202	18041-10000-12356	200 N FALCON ST	90744	15	021B205    24	7440019908	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	02/14/2019 12:00:00 AM		Issued	02/14/2019 12:00:00 AM	ADDRESS	33.75579	-118.2664	PLAN CHECK FOR POWE FOR SHELL OIL COMPANY (REMOVAL AND REPLACEMENT OF BERTH 168 & 169 AND ALL ELECTRICAL EQUIPMENT LOCATED IN THIS AREA) - SCOPE OF WORK INCLUDES PHASE 1 AND PHASE 3 INCLUDING 2 DISTRIBUTION BOARDS CONNECTING TO EXISTING SERVICE RATED AT 2000A AT 2400V. EQUIPMENT BEING INSTALLED ARE 2 NEW DISTRIBUTION BOARDS(400A & 225A) WITH ASSOCIATED EQUIPMENT, AND CONNECTING 2 NEW MINI-POWER STATIONS TO EXISTING MCC(PHASE 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4203	13041-20000-11121	6201 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.18313	-118.60616	Full plan check for change of use to restaurant. Occupancy load is greater than 100. Hook Burger.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4204	19041-10000-48126	6016 N KESTER AVE	91411	6	177A149   103	2241025027	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.1798	-118.45726	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4205	18041-20000-09856	1880 S CENTURY PARK EAST Restrooms	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Issued	05/15/2018 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to restrooms on the 2nd, 3rd, 4th, 7th, 8th, 9th, 10th, 11th, 12th, 15th, and 16th floors. Total lighting area = 5,110 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4206	18041-10000-42143	4610 S MAIN ST 2nd floor	90037	9	112-5A205 280	5109002051	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2285.00	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			PC Info Complete	11/02/2018 12:00:00 AM	ADDRESS	34.00159	-118.27377	TI IN AN EXISTING OFFICE ON THE 2ND FLOOR. SPLITING THE AREA IN TO 3 ROOMS. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 18016-10000-34901	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4207	18041-20000-21754	11034 W SATICOY ST	91352	2	186B173  1170	2315013033	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.20823	-118.37144	Plan check for PV roof mounted system, system size: 3.8kW with 22 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4208	17041-20001-34461	14327 W JOY DR	91331	6	198B153  1033	2644027245	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24151	-118.44545	Changes to an approved set of plans. Equipment ratings have changed and PV system size is now 3.8 kWac.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4209	17041-10000-25468	7540 WORLD WAY Delta Main-Hanger	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	33.94052	-118.42863	Title 24 plan check for the parking lot lighting at the Delta maintenace hanger at LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4210	15041-10001-03973	1656 S ARDMORE AVE	90006	10	126B193   297	5074025015	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	34.04345	-118.30263	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4211	12041-20000-02515	725 S FIGUEROA ST 31st floor	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	T.I. to a high rise building on 31st floor.  Install general/emergency lighting in restroom.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4212	11041-10000-06215	458 S HARTFORD AVE 1-66	90017	1	132A207   104	5153023034	CW	Central	Westlake		YES	2091.01	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM	08/10/2011 12:00:00 AM		Permit Finaled	08/01/2012 12:00:00 AM	ADDRESS	34.05693	-118.26342	New 43. KW PV system for an appartment Bldg. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4213	18041-10000-11959	1645 N NORTH MAIN ST	90012	1	136-5A219 643	5409003036	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.06727	-118.22714	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4214	13041-10000-17960	1413 N L. RON HUBBARD WAY A. S. H.O	90027	13	147B197   870	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.097	-118.29419	New fire alarm system for existing building. 386 fire devices and one fire alarm panel. Partial evacuation plan. 5 Stories with the addition of a basement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4215	15041-20000-20564	8531 N BROWNS CREEK LANE	91304	3	192B105   717	2779010198	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.2256	-118.59192	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel.(18) Kyocera KU 2656 Modules(1) Solaredge SE3800 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4216	10041-10000-13973	338 S WESTERN AVE # D	90020	4	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.01	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.06777	-118.30889	FIRST TENANT  ( LAUNDRY ) IN COMMERCIAL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4217	15041-10000-41703	333 S GRAND AVE LOBBY	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLAN CHECK FOR ENERGY ONLY FOR EXISTING HIGHRISE BUILDING. SCOPE OF WORK IS IN THE LOBBY AREA (GND FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4218	14041-10000-18039	1451 N GARDNER ST	90046	4	147B177  1036	5550025013	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.0977	-118.35305	"PAID INVESTIGATION FEE. Permit to be pulled at EPC counter only. Plan check for energy only. TI to (e) restaurant. BLDG#14016 - 10000 - 09795: Effectuate dispensing and sales of alcoholic beverages per ZA 20012-2019  (CUB) (CU)NO: 106622  -- Building/Electrical/MechanicalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 07/19/2012 by Inspector JOE PARADISO atphone# (213)252-3033.  CEIS Case Number is 473858.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 106623  -- Building/Electrical/Mechanical""COMPLY WITH DEPARTMENT ORDER effective date07/19/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4219	17041-10000-31687	7545 N QUIMBY AVE	91307	12	186B093   190	2021002009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.2073	-118.63131	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 5.0KW/AC  6.38KW/DCSCOPE INCLUDES CENTRAL INVERTER WITH 22MODULES WITH OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4220	15041-10000-29935	10944 W VENTURA BLVD	91604	2	162B173   609	2378007006	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.13979	-118.36893	ALTERATIONS IN EXISTING COMMERCIAL BUILDINGNEW LIGHTING, CIRCUITS AND RECEPTACLESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4221	13041-10000-25738	6102 W SUNSET BLVD UNIT 6102	90028	13	147A189    58	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.09785	-118.32265	TI for a Starbuck's coffee shop in a shopping center (Unit 6102). T24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4222	16041-20000-39437	12745 W ARROYO ST	91342	7	219B161    76	2525019064	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM			PC Info Complete	01/13/2017 12:00:00 AM	ADDRESS	34.29642	-118.40958	Plan check for power and energy. Project site is an existing commercial building. Project scope is new distribution equipment, loads, and lighting. Total lighting area = 46, 942 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4223	16041-10002-09535	209 N PACIFIC AVE	90731	15	018B197   896	7448032029	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	33.74442	-118.28804	PC FOR POWER AND ENERGY. MEDICAL CLINIC. PER BUILDING, NO OSHPD REVIEW. THIS IS PC FOR MEDICAL PER ARTICLE 517. CORRECTED GREEN COMPLIANCE ON PERMIT. THIS IS PC ONLY. PERMIT ALREADY ISSUED FROM MASTER.  B#15016-40000-00825	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4224	14041-20001-10930	4469 N ELLENITA AVE PV1	91356	3	165B117    97	2178025041	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	ADDRESS	34.15116	-118.56345	THIS APPLICATION IS FOR PLAN CHECK ONLY. PERMIT ALREADY ISSUED UNDER ORIGINAL APPLICATION. 32 MODULES, 6.8KW AC. NONSTANDARD PLAN USING 2 CENTRAL TRANSFORMERLESS INVERTERS. 6.89 KW ROOF MOUNTED SOLAR INSTALLATION. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4225	18041-20000-26632	5751 W VALLEY OAK DR	90068	4	151-5A191 155	5587013038	RE9-1D	Central	Hollywood	Hollywood United	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.10984	-118.31483	Plan check for PV roof mounted system, System size: 10.4kW with 41 modules and 2 inverters(5.2KW AC) connected to 200 A Panel. Derated main breaker. Service load calculation has been provided.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4226	18041-10000-24127	5214 W 104TH ST	90045	11	090B173   322	4129035017	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Issued	06/28/2018 12:00:00 AM	ADDRESS	33.94169	-118.37064	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4227	14041-10000-09414	7715 N MARY ELLEN AVE	91605	2	186B157    22	2303016025	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.21038	-118.41958	PV1 5.25KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(21)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4228	17041-20000-01686	9742 N CACTUS AVE	91311	12	201B097    91	2724010016	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.24737	-118.62148	PV1.  Install 4.42 kW roof-mounted PV system.  (17) modules with (1) 3 kW rated central inverter.  (E) 8 kW rated system also present at site.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4229	12041-10000-17627	7055 W SUNSET BLVD	90028	13	147B181   581	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			PC Approved	09/06/2012 12:00:00 AM	ADDRESS	34.09813	-118.34337	CREATE OPENING AND COMBINED RETAIL AND RESTAURANT TO CHANGE OF USE TO RESTURANT.  OCCUPANCY LOAD IS 79 AND LOAD IS 320A PER APPLICANT.  PLAN CHECK ONLY FOR ENERGY, WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4230	14041-20000-24776	14300 W SHERMAN WAY	91405	6	183B153   134	2217006037	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Info Complete	09/10/2014 12:00:00 AM	ADDRESS	34.20099	-118.44464	TI IN EXISTING RESTROOMS. CHANGING LIGHTS TO LEDS.ELECTRICAL PERMIT WAS ISSUED UNDER 14041-20000-22574 & 14041-20001-22574.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4231	14041-20000-02421	6904 N VANTAGE AVE #115	91605	2	183B165   722	2321010076	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.19578	-118.39751	PV1 SOLAR FOR SINGLE UNIT. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4232	13041-10001-36093	2030 N CUMMINGS DR	90027	4	151-5A195 179	5589009019	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			Reviewed by Supervisor	02/04/2014 12:00:00 AM	ADDRESS	34.10803	-118.30192	PV1 ONE STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 10.0-1 KW STANDARD PLAN. [INVERTER: fronius] [SOLAR MODULE: TRINA SOLAR TSM-PC/PA05]. no fee due to 2012 senate bill 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4233	18041-10000-35676	6000 W SANTA MONICA BLVD	90038	13	144B189   689	5534020***	(T)(Q)A1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	01/11/2021 12:00:00 AM		Issued	01/11/2021 12:00:00 AM	ADDRESS	34.09049	-118.32049	(N) 5-STORU TYPE 1-A OPEN AIR MAUSOLEUM/COLUMBARIUM BUILDING AT HOLLYWOOD FOREVER CEMETARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4234	08041-10001-24249	4947 W ROSEWOOD AVE 1-5	90004		141B193  1316	5522017003	R3-1		Wilshire	Greater Wilshire			Electrical	Electrical	Apartment			02/16/2010 12:00:00 AM			PC Approved	02/16/2010 12:00:00 AM	ADDRESS	34.07942	-118.31305	Supplemental application, original plans were lost.  T-24 Energy (general/emergency) lighing plan check for common areas of new 2 story apartment building. Parking spaces in garage is for more than 8 vehicles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4235	11041-10000-10216	11766 W WILSHIRE BLVD 8th	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM	05/18/2011 12:00:00 AM		Issued	05/18/2011 12:00:00 AM	ADDRESS	34.04804	-118.46227	tITLE 24 ENERGY FOR 8TH FLOOR OF A HIGH RISE BLDG. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4236	16041-10000-26882	303 S VAN NESS AVE	90020	4	135B189   187	5504022026	R3-1XL	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.06874	-118.3153	INSTALLATION OF  A NEW FIRE ALARM SYSTEM FOR AN  APARTMENT BUILDING WITH 2 FA PANELS AND 175 FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4237	17041-20001-04302	3322 W BEVERLY BLVD	90004	13	138A201   136	5501018001	C2-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Approved	04/07/2017 12:00:00 AM	ADDRESS	34.07304	-118.28506	[[[4/7/17 CHANGES TO APPROVED T24 ENERGY. DELTA 2 CHANGES ARE CLOUDED.]]]]PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CHILDRENS DAYCARE WITHIN MULTI-FAMILY COMPLEX. 4450SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4238	15041-20001-02106	13003 W GARBER ST	91331	7	204B161    45	2623001024	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.25895	-118.41587	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.(32) SUNPOWER 327W MODULES(2) POWER ONE PVI-5000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4239	11041-10000-20642	1021 S DOREEN PL BLDG 35	90291	11	111B145   793	4243003034	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.00011	-118.46025	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4240	17041-20000-11765	1396 W EAGLE VISTA DR	90041	14	162A229    35	5691012036	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Issued	04/11/2017 12:00:00 AM	PIN	34.14008288	-118.19424559	pv1install roof moute pv system sized 6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4241	17041-10000-12610	3121 W OLYMPIC BLVD #102	90006	10	129B193   271	5080024027	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.05277	-118.30387	PC for 24 for kitchen TI. Total sqft is 2370 sqft. PC for new lights. Load is under 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4242	17041-10000-36884	742 S CLOVERDALE AVE	90036	4	132B181   166	5089002015	[Q]R4-1-HPOZ	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.06096	-118.34655	PC for 10.4kW rooftop solar and 32 modules. Installing 32 modules, 6.6kW inverter, 3.8kW inverter and 125A load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4243	10041-20000-16948	851 W DOWNEY WAY	90089	8	118-5A201  14	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.02004	-118.28659	LIGHTING AND POWER. P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4244	14041-20000-26087	3852 N LONGRIDGE AVE	91604	2	162B161   438	2385012036	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	PIN	34.14090451	-118.41897905	PV1 SFD. TOTAL SYSTEM SIZE 5.52KW AC USING MICROINVERTER SYSTEM. USING ENPHASE M250. USING STANDARD PLAN. TOTAL OF 23 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4245	17041-20001-11703	8833 N RESEDA BLVD unit a	91324	12	195B125   466	2770016008	C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM			PC Approved	06/16/2017 12:00:00 AM	ADDRESS	34.23172	-118.53627	6/16/17changes to an approved set of plans.  medical office.  plan check for power and energy.the permit fees paid under 17041-20000-11703.This is plan check only.(((((ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 648.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4246	12041-10000-20763	121 W 60TH ST	90003	9	105B201   469	6005015015	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.00	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Closed	11/30/2012 12:00:00 AM	ADDRESS	33.98525	-118.27468	Title 24 for ti  in a two story church with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4247	17041-20004-45582	16633 W OAK VIEW DR	91436	5	168B137   395	2289020013	R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.15694	-118.49746	05/01/2018 Changes to an approved set of plans. All changes have been clouded. Electrical equipment has been relocated to match field installation.*****Previous Work Description*****Revisions to approved set. Relocation of equipment.  $0 plan check fee per State Senate Bill SB 1222.02/28/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the configuration of system interconnection.*****Previous Work Description*****Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(36) 300W pv modules. (2) 5kW Tesla Powerwall 2s.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4248	13041-20000-31347	8666 N RINCON AVE	91352	6	195B165   757	2634033015	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.22732	-118.39704	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING 14 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4249	15041-10000-16075	1350 S SOTO ST	90023	14	121-5A221 212	5170019015	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM			PC Info Complete	06/03/2015 12:00:00 AM	ADDRESS	34.02519	-118.21956	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING TWO NEW LIGHTING FIXTURES TO EXISTING CONTROLS AND PANEL. PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE  696.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4250	14041-20002-16403	11132 W VENTURA BLVD	91604	2	162B173   371	2378009007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	11/13/2014 12:00:00 AM	ADDRESS	34.1414	-118.37315	[[[[11/13/14  CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. DELTA 1 CHANGES ONLY. CHANGES PER INSPECTORS REQUEST. ]]]]PV2.  Install 32.94 kW DC roof-mounted, utility-interactive PV system.  (3) transformerless inverters.$0 permit fee due to Senate Bill SB-1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4251	19041-10000-48408	2115 N GAFFEY ST	90731	15	024B197     5	7442002002	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM			Reviewed by Supervisor	12/05/2019 12:00:00 AM	ADDRESS	33.76516	-118.29378	"Replacing existing lights in an existing ""Home Depot"" with new lights. Affected area:131,228 SFT (INDOOR) + 12,045 SFT (OUTDOOR)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4252	11041-20000-05369	3415 S SEPULVEDA BLVD 4th Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	"T.I. for a high rise building.  Install general/emergency lighting in elevator lobby and corridor.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4253	14041-20000-02011	7515 N LANKERSHIM BLVD	91605	2	186B169   441	2317009028	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.20703	-118.38798	TI FOR EXISTING RESTAURANT. OCCUPANT LOAD EXCEEDS 100 OCCUPANTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4254	13041-10000-30863	108 S KINGSLEY DR	90004	10	138B193   976	5517021033	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.07346	-118.30278	PV1, Install 7 kW DC roof-mounted photovoltaic system interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. , power optimizer, 28 modules: HANWHA # HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4255	17041-20000-38120	2351 N ACHILLES DR	90046	4	153B173   795	5569007056	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.11347	-118.36716	Plan check for AC coupled battery backup system for SFD.Existing solar system on site.(2) Tesla Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4256	15041-20000-26661	669 W 34TH ST	90731	15	006B197   394	7467010022	RD2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2976.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Closed	01/08/2016 12:00:00 AM	ADDRESS	33.71324	-118.29139	Plan check Title 24 only for USC replace esisting fluorescent light fixtures with LEd light fixtures in corridor area . Total indoor1,803 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4257	15041-20000-11068	6801 W HOLLYWOOD BLVD A1-103	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	Title 24 plan check only.  Total area = 458 sq. ft.  T.I. to existing retail space, sunglasses/optical shop.  New lighting incl. emergency.CRA clearance to be cleared under building permit #15016-10000-07079	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4258	14041-20000-22333	1434 W SLAUSON AVE	90047	8	108B193  1379	6002004025	[Q]CM-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.01	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	33.98899	-118.30145	Title 24 plan check only for a commercial building. total area 1402. Plan check based on 2008 energy code due to building plan submited before July 1st.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4259	13041-10000-30047	3619 N WESLIN AVE	91423	4	162B157   955	2386013003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.13648	-118.43091	PV1, Install 11 kW DC roof-mounted solar array, interconnect with service panel. Multiple transformerless inverters. 44 modules: HANWHA # HSL60P6-PB-4-250TW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4260	18041-10000-47226	13800 W ROSCOE BLVD	91402	6	192B153   776	2213016023	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.22149	-118.43346	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4261	15041-10000-27244	7505 W MELROSE AVE	90046	5	141B177   598	5526012030	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.08378	-118.3535	Energy plan check for an existing restaurant T.I. Scope includes new lighting and equipment, total area is 2521-SQ feet. Permit fee is paid under express permit #: 15041-30000-25305.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4262	14041-20000-23039	4027 N ROCK HAMPTON DR	91356	3	165B125   474	2184054011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.14443	-118.53689	$0 permit fee is due to Senate Bill SB-1222.  pv1 single family. total system size 11kw AC using 2 central transformerless inverters. using total of 50 modules. nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4263	15041-10000-12543	13551 W BURBANK BLVD	91401	2	174B157   590	2343011018	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			04/27/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.17229	-118.4287	New fire spindkler monitoring system with (1) fire alarm panel, and (6) fire alarm devices for a new 2-story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4264	19041-20000-04168	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/04/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.18421	-118.60617	Service upgrade for (E) retail shell building.  1600A 480Y/277V service.  Building permit under 19016-20000-03245.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4265	16041-10000-41781	15801 W MAYALL ST	91343	12	204B141   785	2669013004	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.25384	-118.47639	PV INSTALL NEW 6.480 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(18) AC MODULES: SPR-X22-360-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4266	19041-20000-48445	22171 W MARYLEE ST	91367	3	174B101    51	2146020002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.1765	-118.6099	PV1.  Install 15.410 kW DC roof mounted grid tied PV system.  (46) modules with (23) 720W microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4267	10041-20000-11314	3233-3237 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035012	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.02889	-118.37311	Thomas  Wylde t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4268	14041-20001-06358	16739 W ADDISON ST	91436	5	171B137   216	2259003021	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	04/18/2014 12:00:00 AM	ADDRESS	34.16315	-118.49819	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 CENTRAL INVERTERS WITH ISOLATION TRANSFORMER. CONNECTED TO 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4269	19041-10001-53257	8900 W VENICE BLVD	90232	5	120B169    20	4312014093	(Q)M1-2D	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Approved	03/13/2020 12:00:00 AM	ADDRESS	34.02908	-118.38822	EXPEDITE PER APPLICANT REQUEST. PV2. NEW SOLR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 71.04KWdc / 62.5KWac. (222)MODULES- BOVIET BVM6612P-320W/5BB(320W)(1)INVERTER-SMA TRIPOWER CORE1 STP 62-US-41	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4270	16041-20001-16607	7066 N MIDDLESBURY RIDGE CIR	91307	12	183B089   215	2028042014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.19922	-118.6482	Expedite per applicant request{{{{{Plan check  PV roof mounted system addition of 3.0kW to existing 5.0kW. Addition of 8 modules and 1 inverter(3.0kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4271	17041-10000-41355	629 S HILL ST	90014	14	129A209   158	5144003900	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Public Safety Only			11/15/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.04683	-118.25384	NEW FIRE WARNING SYSTEM FOR COMMERCIAL BUILDINGNOTE: BUILDING UNDER FIRE WATCH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4272	17041-10000-20988	21622 W SHERMAN WAY	91303	3	183B105   149	2111026904	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	34.20081	-118.60101	Replace fire alarm control panel.  All other devices to remain existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4273	14041-10000-04667	4652 N WORTSER AVE	91423	4	168B161   660	2362003002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Expired	05/02/2016 12:00:00 AM	ADDRESS	34.15553	-118.4169	PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(19) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4274	19041-10000-26300	1605 W COLORADO BLVD	90041	14	162A225    47	5669016031	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	01/11/2021 12:00:00 AM	ADDRESS	34.13968	-118.20125	PC ENERGY ONLY FOR CHANGE OF USE OFFICE BUILDING TO MEDICAL OFFICE. AREA OF SCOPE 1,710SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4275	14041-10000-01451	5450 N ETHEL AVE	91401	4	174B161   687	2345011019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.16996	-118.41799	pv1, roof-mounted solar installation , interconnecting with (E) 120/240 V service. system size is 5.25 kW DC, with 3 paralleled strings. combiner box to be used for the placements of  (3) 15A fuses. System is consists of the following components:(21) Trina solar #tsm-250pa05.18(1) Fronius # IG 5100 NEG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4276	16041-20001-26352	1071 N STRADELLA ROAD	90077	5	144B149   202	4369036019	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.09121	-118.45392	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system.(25) 290W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4277	17041-10000-44853	2027 S SANTA FE AVE	90021	14	118-5A217  50	5167012036	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.02033	-118.23042	PC for power only. Scope includes a New 800 Amp 120/240V 3phase 4 wire service/distribution board to feed existing loads. No new power added to existing distribution system.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4278	16041-10000-25703	515 S MOLINO ST	90013	14	126A217   220	5163021038	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.04129	-118.23411	PC for energy only to a retail store building single story unit. Installing new lighting and power, receptacles, and a new panel rated at 200 amps. Totalsqft =6540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4279	15041-20000-19281	7609 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.20886	-118.46495	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 3.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4280	15041-10000-41295	9600 N LURLINE AVE	91311	12	201B109   290	2748040027	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Issued	01/14/2016 12:00:00 AM	ADDRESS	34.24455	-118.58404	NEW DESIGN. INSTALLING 3 INVERTERS. 108 MODULES TOTAL. SYSTEM SIZE 34KW AC. LINE SIDE CONNECTION	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4281	10041-10002-17266	1375 N WESTERN AVE	90028	13	147A193   170	5544030055	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM			PC Approved	03/22/2011 12:00:00 AM	PIN	34.09654211	-118.30960546	ON-SITE CHANGES MADE -REVISED SETS OF PLANS TO INCORPORATE THESE CHANGES-NEW CKTS ADDED TO PANEL C; CHANGE AC UNITS TO CU UNITS HAVING SMALLER VA RATINGS; WALK-IN COOLERS WITH LARGER VA RATINGS. CHANGES REFFERED TO AS DELTA 2.ADDED 100A PANELBOARD AND 8 EA NEW CIRCUITS; LIGHTING LOADS WERE INCREASED((((((((CHANGE PORTION OF EXISTING BLDG FROM REPAIR GARAGE TO RESTAURANT, 5800 SF, TYPE V-B CONSTRUCTION, OCCUPANCY CHANGE FROM F-1 TO A-2. TI CONSISTS OF INTERIOR WORK, NEW RESTROOMS, EQUIPMENT, DINING/SEATING.  REF.#10042-10000-19412.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4282	19041-10000-37091	5561 W ADAMS BLVD	90016	10	123B177   968	5048001056	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.03262	-118.36408	T-24, ENERGY PLAN CHECK ONLY. REMODEL OF EXISTING GROUND FLOOR OFFICE SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. INDOOR AND OUTDOOR 1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4283	17041-10000-25399	330 E 3RD ST	90013	14	129A213   211	5148004006	C2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.04738	-118.24296	PC for fire damafe repair. new 600A service. pc for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4284	15041-20000-17076	1215 E PACIFIC COAST HWY	90744	15	036B209   629	7426016024	[Q]C1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			PC Approved	06/08/2015 12:00:00 AM	ADDRESS	33.79111	-118.24826	Plan check for Title 24 only. Project site is a existing commercial building. Project scope is indoor lighting. Total lighting area = 3,955 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4285	13041-20000-04297	13020 W SAN VICENTE BLVD	90049	11	129B137   491	4264001007	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	ADDRESS	34.04845	-118.49051	Plan check for energy and emergency lighting. Velvet. Woman's clothing store. Tailored method.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4286	13041-10000-11656	6707 S BROADWAY	90003	9	102B201   194	6012006032	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	33.97876	-118.27849	TI to an existing single story fast-food restaurant.  New lighting and receptacles in kitchen and outdoor area.  Title 24 plan check only.  Permit already obtained under 13041-10000-04919	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4287	18041-20001-12897	12744 N SAN FERNANDO ROAD Bldg 2	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.30155	-118.46112	"08-23-2018 Changes to an approved set of plans. Changes include lighting layout configuration, remove lighting fixture ""C"", update photometrics calculaiton . Changes has been cluded."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4288	16041-10001-40354	500-506 S SAN PEDRO ST	90013	14	127-5A213 248	5147025022	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.0439	-118.24387	SERVICE UPGRADE TO 800AMP AT THE SAME LOCATION. RECONNECT TO EXISTING LOADS. NO NEW LOAD ADDED. B# 16016-10000-27392	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4289	17041-10000-15944	20945-20947 W ROSCOE BLVD	91304	3	192B109   680	2779007019	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM			PC Info Complete	05/12/2017 12:00:00 AM	ADDRESS	34.22007	-118.58997	PC for TI, energy only in a comm. building due to fire damage.Scope includes new panels, circuits and lights.Total affected area 4260 sq.ftPERMIT PULLED UNDER  17041-20000-41305B# 17016-30000-05447	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4290	14041-20000-17906	12000 W IDAHO AVE 1-8	90025	11	126B145   893	4259003006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.03918	-118.46049	$0 permit fee due to senate bill 1222 from 2012pv2 commercial roof top. 37kw	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4291	19041-10000-34113	611 E 59TH ST	90001	9	105B205    25	6007002019	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Expired	02/01/2023 12:00:00 AM	ADDRESS	33.98728	-118.26433	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY IND/OUT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4292	17041-10002-31224	21900 W BURBANK BLVD SUITE 300	91367	3	174B105    46	2146007120	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Issued	10/10/2017 12:00:00 AM	ADDRESS	34.17189	-118.60404	CHANGES TO AN APPROVED SET OF PLANS.  ALL CHANGES ARE CLOUDED UNDER DELTA 4. CHANGES INCLUDE ADDING BUG EYES ON THE LIGHTING FLOOR PLANS, AND REVISING EMERGENCY PHOTOMETRICS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4293	18041-30000-06558	1261 S STONER AVE 1-8	90025	11	129B145   887	4263008009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Apartment			02/22/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.04711	-118.46065	Full PC for power and energy for a new 4 story 8 unit apartment, 4 story building with garage. Scope includes a new 800A 120/240 3 phase 4 wire service/distribution board, new panels, and new circuits. There are three typical panels for all 8 units. Total affected area is 11,485 Sq. ft. B#16010-30000-01721	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4294	14041-20000-07399	11550 N INDIAN HILLS ROAD	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.27998	-118.45874	PV2 110.4KWAC SYSTEM FOR COMMERCIAL SPACE. BUILDING APPROVAL IS REQUIRED BEFORE PERMIT CAN BE ISSUED.(($0 permit fee due to senate bill 1222 from 2012)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4295	10041-10000-05656	635 W 35TH ST	90089	8	118-5A201  22	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	05/21/2010 12:00:00 AM		Permit Finaled	07/29/2010 12:00:00 AM	PIN	34.01952527	-118.28703756	T-24 and emergency lighting plan check only for the ground floor lobby and support areas.  Less than 400 amperes of load added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4296	19041-10000-11964	351 W FLORENCE AVE	90003	9	102B201   788	6012012060	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	33.97483	-118.28018	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4297	13041-20000-22842	725 W SOLANO AVE	90012	1	139-5A217  22	5415024032	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural	YES	2060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.07756	-118.2338	pv1 single family dwelling. total system size 3.6 kw using 22 modules. using transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4298	12041-20000-02207	1990 S BUNDY DR 440	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/30/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.03419	-118.45559	T24 lighting plan check for suite 440.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4299	14041-20000-24021	4643 N CAMELLIA AVE	91602	2	168B169   811	2354014036	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.15518	-118.38242	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW.(1) SolarEdge SE5000A-US transformerless inverter(14) CS Solar CS6P-250P pv modules(6) CS Solar CS6P-235PX pv modules(20) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4300	13041-10000-17639	12879 W RUNWAY ROAD Units 1-3	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/03/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	33.97525	-118.42037	PLAN CHECK POWER AND ENERGY FOR NEW 3-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #5  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4301	18041-20002-35624	350 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A203 152	5111003039	[Q]M1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM			PC Info Complete	11/21/2019 12:00:00 AM	ADDRESS	34.01092	-118.27958	11/21/19CHANGES TO APPROVED SET DELTA B ONLY. ADD NEW PANELS, EQUIPMENTS, TRANSFORMERS AND NEW LOADS.(((ti to an existing commercial building (green house) with service upgrade 5000 amp.  adding new transformers, panels, circuits and backfeeding existing panels.  plan check for power and energy.serice to suppy the following address 4001 S. Broadway.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4302	11041-10001-19892	900 S BROADWAY	90015	14	127-5A209 247	5139002018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	ADDRESS	34.04213	-118.25602	Modification to previously approved set for T-24 only.<<<<<INTERIOR REMODEL OF EXISTING RETAIL SPACE FOR 7-ELEVEN.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4303	13041-10000-07866	6133 N TOPANGA CANYON BLVD	91367	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.18184	-118.60616	Service upgrade to 800Amp.  (Phase 1)ORIGINAL APPLICATION FOR PERMANENT INSTALLATION UNDER #13041-10000-05529	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4304	12041-10000-01586	3757 S SEPULVEDA BLVD	90066	5	117B161  1108	4252001011	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2012 12:00:00 AM			Reviewed by Supervisor	05/24/2012 12:00:00 AM	PIN	34.01337096	-118.41796794	New 2.88 kw rooftop photovoltaic for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4305	18041-20000-31425	1864 N VERMONT AVE	90027	4	150B197   931	5590015003	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.10489	-118.29162	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use to retail/tenant improvement. Total lighting area = 3,029 sq. ft.Note: Building application has been generated under 18016-10000-25998	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4306	19041-10000-16905	7424 W MELROSE AVE	90046	5	141B181   601	5526019032	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.08341	-118.35188	PLAN CHECK FOR TITLE 24 ONLY FOR NEW RESTROOM. TOTAL EFFECTED AREA 49 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4307	19041-10000-31174	521 N GRAMERCY PL 1-32	90004	4	141B193  1075	5522014014	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			08/09/2019 12:00:00 AM	03/09/2020 12:00:00 AM		Permit Finaled	03/02/2022 12:00:00 AM	ADDRESS	34.08091	-118.31275	Full plan check for power and energy. Scope of work includes new 1200A 120/208 V, 3ph 4 wire service/distribution board, 32 new panelboards, New lighting, circuits and equipment. Total sq. ft. 16322	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4308	19041-20000-44202	10904 N ZELZAH AVE	91344	12	210B129   817	2712011016	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.26877	-118.52329	PV1. INSTALL 7.56 KW DC PV SYSTEM WITH (24) MODULES/OPTIMIZERS, (1) INVERTER (SE7600H) AND (2) TESLA ENERGY STORAGE BATTERIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4309	13041-10000-33927	867 S WELLESLEY AVE	90049	11	129B141   624	4264017001	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.04583	-118.47528	PC ONLY FOR PV1. CHANGES OF ROOF LAYOUT AND REDUCTION OF MAIN BREAKER SIZE FROM 200 TO 175.ORIGINAL PC UNDER 13041-10000-27670. PV1 - ROOF-MOUNTED SOLAR INSTALLATION WITH 16 MODULES , USING M215 ENPHASE MICROINVERTERS, ON STANDARD PLAN IN 2-STORY HOUSE. TOTAL AC OUTPUT = 3.45KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4310	19041-10000-11588	1019 E 4TH PL floor 1	90013	14	127-5A217  62	5163018006	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.04195	-118.23327	FULL PLAN CHECK FOR FIRST TIME TENANT FOR - FULL FLOOR 7,773 SQFT. (LEVEL 1)OFFICE USE. THE SCOPE OF WORK INCLUDES INTERIOR NON-LOAD BEARING PARITTIONS, AND FINISHES - CONNECTED TO EXISTING SERVICE - NEW COONECTED LOAD IS APPROX. 200A OF CONNECTED LOAD USING TRANSFORMER(75KVA), TOTAL AFFECTED AREA = 19650 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4311	19041-20001-24554	704 S HARTFORD AVE pv2	90017	1	130-5A205 165	5143009002	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	34.05179	-118.26737	expeditepv2install roof mounted pv system sized 10KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4312	14041-10000-06445	1302 W 177TH ST BLDG F	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	INSTALLATION OF A FIREALARM FOR A NEW JUVENILE IMPACT PROGRAM SHELTER (BUILDING F).  1 PANEL AND 12 DEVICES.6 OF 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4313	16041-20000-03714	4825 N NEWCASTLE AVE	91316	5	168B125   386	2181029024	R1-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.15706	-118.52526	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.21 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4314	11041-10000-18044	17601 S DENVER AVE	90248	15	063B201   105	7339007016	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	33.87066	-118.28305	T.I.  Existing office space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4315	15041-20000-38096	8552 N OUTLAND VIEW DR	91352	2	192B177   175	2404028007	RE15-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Issued	12/09/2015 12:00:00 AM	ADDRESS	34.22452	-118.35778	$0 permit fee is due to State Senate Bill SB-1222PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.7KWdc/10.0KWac. (45) MODULES-CANADIAN SOLAR CS6P-260P(2)INVERTERS-FRONIUS PRIMO 5.0(1)SUBPANEL-100A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4316	16041-10000-35585	1324 E 15TH ST	90021	14	121-5A211 279	5130014027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.02645	-118.24741	T-24, PC FOR ENERGY ONLY. TI TO AN EXISING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 25045 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4317	16041-10000-31679	14673 W CHATSWORTH ST	91345	7	207B149   320	2648020029	RA-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.26456	-118.45179	PV 1 roof mounted solar system installation to a single family home. Installing 39 microinverters rated at 280 watts each for a total system size of 10.92 KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4318	14041-10002-13483	8570 W COLE CREST DR	90046	4	150A173   757	5556014049	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.10346	-118.37773	03-20-2017 Changes to an permited set of plans. Changes include remove bettary from PV System, Change the inverter manufacture to Sunny Boy 7.0-US and additional 3 modules. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4319	12041-10000-02865	700 W WORLD WAY # 7B	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	INTERIOR REMODEL OF EXISTING 1,069 SQFT RETAIL SPACE AT 7B TERMINAL 7 LAX FOR NEW KISTON STORE: NEW TENNANT .Plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4320	16041-10001-19683	6154 W 76TH ST	90045	11	099B165    38	4106016027	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	33.97134	-118.39392	Plan check for solar.  Changes to permit - addition of three modlues.  Original permit issued online.Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4321	15041-20000-01809	10530 W VICTORY BLVD	91606	2	177B177    90	2414019012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			Reviewed by Supervisor	03/02/2015 12:00:00 AM	ADDRESS	34.18498	-118.36061	INSTALL OF 72 MODULES. PV2 COMMERCIAL ROOFTOP. SYSTEM USES 2 - 10KW INVERTERS. 3 PHASE SERVICE. PER APPLICANT BUILDING HAS 2 INDEPENDANT SERVICES. TOTAL SIZE 18KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4322	12041-10000-07858	8515 N EATOUGH AVE	91304	12	192B101   189	2010018006	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	34.22489	-118.6101	Plan check for new 7.848KW roof mounted photovoltaic system single family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4323	17041-20000-33714	301 N COPA DE ORO ROAD	90077	5	141B153   220	4362013009	RE20-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.0806	-118.44055	Plan check for power only. Project site is an existing single-family dwelling. Project scope is an addition. Work includes a new 800-amp service and new distribution equipment and wiring.Note; Building permit has been issued under 16014-20000-06062	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4324	11041-20000-21029	6420 W WILSHIRE BLVD 19th floor	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/03/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	Remodel of the light fixtures in the corridor and open office space on the 19th floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4325	13041-10000-34131	1439 N POINSETTIA PL 1-39	90046	4	147B181   754	5548019024	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			12/09/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.09717	-118.34858	Plan check for installing fire alarm system for a new 39 Units, 4 story building apartment with 196 devices and one panel.( Mehdi Zandi: PLan check has to assigned for this week 12/9/2013)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4326	18041-10000-36150	10101 S BROADWAY	90003	8	091-5A203 235	6053024019	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			Reviewed by Supervisor	10/02/2018 12:00:00 AM	ADDRESS	33.94445	-118.27854	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR BOTH ROOF/CARPORT MOUNTED PV SYSTEM - INSTALLATION OF NEW CARPORT WITH MOUNTED PHOTVOLTAIC MODULE ROOFING.63.3KVA {61.56KW(AC)}. CONSISTING OF 2 INVERTER (30KVA(SMA3000TL-US) & 33.3KVA (SOLAREDGE SE33.3KUS WITH POWER OPTIMIZERS (P730))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4327	14041-20000-18043	6767 N IRONDALE AVE	91306	3	180B109    16	2148005002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.19356	-118.58503	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(18) TRINA SOLAR TSM-255(1) POWER ONE TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4328	15041-10000-32557	1330 W PACIFIC COAST HWY	90744	15	036B201   795	7415001027	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Info Complete	10/01/2015 12:00:00 AM	ADDRESS	33.79004	-118.28025	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1270.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4329	11041-10003-09788	14530 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	08/27/2012 12:00:00 AM	ADDRESS	34.23519	-118.44861	DELTA 6  PLAN CHECK TO APPROVED PLANS. REVISIONS ARE CLOUDED ON PLAN, ADD#3, CCD#2, AND CCD#3. CHANGES TO LIGHTING, LOADS, SINGLE LINE, AND BRANCH CIRCUITS.These are as-built set of plans	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4330	11041-20000-15067	3415 S SEPULVEDA BLVD #330-340	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	T.I. for a high rise building.  Install general/emergency lighting for Suite #330 & 340 Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4331	14041-20000-33273	22724 W MALDEN ST	91304	12	192B097    60	2004015034	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.2253	-118.62232	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. TOTAL OF 30 MODULES. 3 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4332	15041-10001-06351	7347 N CLAIRE AVE	91335	3	186B121   737	2104028005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM			PC Approved	04/07/2015 12:00:00 AM	ADDRESS	34.20436	-118.55037	EXPESSDITED RSES PLAN CHECK PESR APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4333	13041-10002-23536	3620 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.0213	-118.28935	Seeley g. mudd building 1st and 2nd floor labs renovation.PLAN CHECK FOR POWER AND ENERGY.(Changes made to previously approved set. Additional 400A transfer switch. 2 new emergency panels. Changes to the lighting plan and additional circuits. New transformer) 6/26/14 M.F.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4334	15041-20000-09668	835 W 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	PIN	34.02383917	-118.28572873	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT - REMODEL OF MENS AND WOMENS RESTROOMS ON FIRST FLOOR FOR UNIVERCITY RELIGIOUS CENTER IN USC.  (61 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4335	15041-20001-35678	21850 W OXNARD ST	91367	3	177B105    80	2146006045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.17895	-118.60413	[[6/24/16 CHANGES TO APPROVED SET. CHANGING  FIXTURE F-4S FROM RECESSED TO SURFACE MOUNTED]]]Plan check for energy only for Guestroom & public space renovation. Conversion of concierge lounge back to guest rooms and meeting room to new lounge. Total area: 46,930 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4336	18041-10000-29482	7667 N CHISHOLM AVE	91406	6	189B145   692	2222007018	RS-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.21034	-118.47171	PV1 ROOF MOUNTED SOLAR SYSTEM, SCOPE OF WORK INCLUDES NEW CENTRAL INVERTER WITH POWER OPTIMIZERS. (24) PV MODULES AND OPTIMIZERS AND (1) 6KWAC INVERTER. TOTAL SIZE IS 6KWAC / 7.2 KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4337	15041-20000-00671	16621 W LIGGETT ST	91343	12	198B137   412	2687023010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Expired	02/02/2017 12:00:00 AM	ADDRESS	34.24011	-118.49459	PV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC. THIS IS AN ADDITION TO AN EXISTING PV SYSTEM. TOTAL PV SIZE TO BE 5.6KW. THIS IS ONLY 3.6KW ADDITION. 19 NEW MODULES. NEW SUBPANEL TO HANDLE ADDITION.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4338	19041-10000-16975	905 N YALE ST	90012	1	135A215   138	5414003015	C2-2D-O	Central	Central City North	Historic Cultural North		2071.03	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.06537	-118.23984	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4339	15041-10001-40111	7508 W MELROSE AVE	90036	5	141B177   659	5526017027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Closed	11/23/2016 12:00:00 AM	PIN	34.08337436	-118.35354775	"09/19/2016 CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE ADT RETIAL HEALTH CLINICS IN CVS SPACE AND ADD LOAD TO PANEL ""C""  AND REVISED ENERGY FORMS.  CHANGES APPLY TO DELTA 3 ONLY. PC FOR POWER AND ENERGY. TI TO AN EXISTING COMMERCIAL BUILDING (CVS PHARMACY)."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4340	10041-10001-19357	1901 S OVERLAND AVE	90025	5	129B157   604	4321010048	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			03/09/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	34.05001	-118.43196	INSTALL NEW EMERGENCY LIGHTS & EXIT SIGNS IN THE HALLWAYS AND EXIT PATHS ON THE 1ST & 2ND FLOORS.   <<<<<<<<<<EXISTING PERMIT # 10041-20000-19357>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4341	14041-20000-05051	5500 W SUNSET BLVD	90028	13	147A193   108	5544029011	[Q]C2-2D	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Closed	06/16/2020 12:00:00 AM	ADDRESS	34.09793	-118.30958	Temporary 1200A service new Target Store.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4342	16041-20000-06533	17401 W VENTURA BLVD #A-39	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.16136	-118.51189	CHANGE OF USE FROM CHIROPRACTOR'S OFFICE TO BEAUTY SALON.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4343	16041-10000-10828	641 E 43RD PL	90011	9	114A207   378	5115010020	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Apartment			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Expired	04/27/2018 12:00:00 AM	ADDRESS	34.00492	-118.26437	Solar installation on 1 out of 3 unit multifamily dwelling. 3kW AC    (14) KD255GX-LFB3      (1) PVI-3.0-OUTD. Plan is approved ny F.A Dept.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4344	19041-20000-41389	11825 W TERRA VISTA WAY #137	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4345	19041-10000-28695	100 WORLD WAY 1.5	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	10/19/2021 12:00:00 AM	ADDRESS	33.94572	-118.40095	Energy plan check for a bridge connector between terminal (1.5) and terminal (2). Scope includes new lighting and equipment with a total lighting area of 5,260-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4346	14041-20000-21011	11827 W VENTURA BLVD	91604	2	162B169   216	2368006014	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM			Corrections Issued	08/05/2014 12:00:00 AM	ADDRESS	34.14245	-118.38988	3700 sq. ft. commercial office TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4347	17041-10000-16210	1640 S SEPULVEDA BLVD #205	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.04838	-118.44468	Plan check for Title 24 only in existing space T.I. office.  Total area: 2,012 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4348	15041-10000-28302	505 S VIRGIL AVE Ste # 300	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.0649	-118.28724	Full plan check for a general medical practice office; Scope include new light and receptacle. Total area is 3786-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4349	17041-20000-02008	15821 W VENTURA BLVD 5th Floor-Corridor	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for Title 24 only. Project site is the 5th floor corridor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,639 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4350	18041-20000-11545	11835 W OLYMPIC BLVD #400	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.03301	-118.45119	Plan check for power and energy. Project site is an existing tenant space within a commercial high-rise building. Project scope is a change of use from office to medical (dental)/tenant improvement. Total lighting area = 2,569 sq. ft.Note: Building application has been generated under 17016-10000-38066	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4351	12041-20000-08164	12150 N BELLANDO CT	91344	12	219B125    93	2601074003	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Expired	09/04/2014 12:00:00 AM	ADDRESS	34.29503	-118.52543	Photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4352	15041-10000-16626	7020 N WOODMAN AVE	91405	2	183B157   423	2328009037	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			06/01/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.19821	-118.43105	(N) addressable fire alarm system in 4-story apartment building.  88 devices with FACP and annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4353	19041-20000-16680	22135 W ROSCOE BLVD LOT #10	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	Plan check for PV roof mounted system, System size: 2.1KW with  7 PV Modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4354	15041-20000-19574	900 E 4TH ST	90013	14	127-5A215 232	5163022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.04339	-118.23627	Installation of new fire alarm system in new lowrise commercial building. 21 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4355	11041-20000-17026	330 E WASHINGTON BLVD A-D	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	33.98065	-118.46362	energy plan check salon	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4356	13041-10001-05362	4602 N SALOMA AVE	91403	4	168A149   153	2264020010	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			Corrections Issued	07/05/2013 12:00:00 AM	ADDRESS	34.15413	-118.45836	Supplemental: Change of modules from REC 245 PE to REC 250 PE.Original description: 3.43 KW SOLAR INSTALLATION {14 MODULES: REC 245 PE BLK} {MICROINVERTERS: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4357	19041-20000-27104	20130 W LORNE ST	91306	3	189B113   261	2107017134	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.21706	-118.57219	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4358	10041-10000-24239	5001 W RODEO ROAD	90016	10	120B181   948	5046013900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM	12/06/2010 12:00:00 AM		Permit Finaled	01/07/2011 12:00:00 AM	ADDRESS	34.02168	-118.35178	NEW SERVICE FOR EXTRIOR LIGHTING OF AN EXISTING TENNIS COURT AT A LA CITY RECREATIONAL CENTER ; LUMINAIRES ARE MOUNTED ON 40 FT POLES ( APPROVED UNDER SEPARATE BLDG PERMIT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4359	16041-10000-43163	1104 S HOOVER ST	90006	1	130-5A201 222	5136016006	C2-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.05145	-118.28399	Plan check for Titel 24 only in existing space Fire damage to the roof. Total area: 4,614 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4360	16041-10001-37256	5626 N TUJUNGA AVE	91601	2	174B173   815	2337039010	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.17271	-118.3789	Changes to approved set.  Changes to lighting layout and updated Title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4361	15041-10000-16477	2379 S PROSSER AVE	90064	5	126B157   288	4320013019	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.0442	-118.42141	ALTERATIONS IN A NAIL SALON.  PLAN CHK IS FOR TITLE 24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4362	17041-10000-05277	4269 S FIGUEROA ST	90037	9	114A201   286	5019014030	C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.00568	-118.28296	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 17,000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4363	17041-10000-41760	1402 N ALTA VISTA BLVD	90046	4	147B181   964	5548021043	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.09601	-118.34685	Remove Outdoor HID fixtures and replace with new LED fixtures. T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4364	17041-10000-08975	2300 W OLYMPIC BLVD	90006	1	130-5A201 147	5136015030	C2-1, C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.05211	-118.28259	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 20850 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4365	16041-20001-40252	720 S HOBART BLVD	90005	10	132B193   425	5093018023	R3-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	11/19/2016 12:00:00 AM	ADDRESS	34.05889	-118.30517	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 31.7kW (6kW*4+7.7kW) ungrounded system. (116) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4366	15041-20000-10556	14415 1/2 W TERRA BELLA ST	91402	6	198B149   349	2639009***	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Apartment			04/09/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Expired	05/17/2017 12:00:00 AM	PIN	34.23806836	-118.44683529	PV2. MULTI FAMILY UNITS. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.16KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4367	13041-10001-29369	5200 W CENTURY BLVD	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	33.94516	-118.37049	aCCORDING TO THE CONTRACTOR ALL BREAKERS ARE EXISTING AND NEED PLAN CHECK ONLY TO PUT EVERYTHING BACK EXISTINGPLAN CHECK FOR POWER. TENANT IMPROVEMENT. ( MECHANICAL UPGRADES) PROVIDE ELECTRICAL POWER SUPPLY TO NEWLY REPLACED CHILLERS, COOLING TOWER PUMPS AND AIR COMPRESSERS. NEW CONNECTED LOAD 1065.5 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4368	19041-10000-46925	7333 WORLD WAY WEST F/A	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/24/2020 12:00:00 AM	ADDRESS	33.94247	-118.42449	Plan check for a new fire alarm system. Scope includes (1) control panel, (1) fire alarm panel, and (58) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4369	16041-10002-04433	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.01318	-118.34004	Supplemental PC for new voice alarm communication system and devices. All clouded changes are are under delta 1. Changes made per fire department requirement LAFC 1005.3.1 as described in scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4370	17041-20003-44638	3315 W 41ST ST	90008	10	114B185   300	5024028027	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.01015	-118.33021	"Revisions to approved set.  Relocation of equipment to location by MSP.  $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414. (((CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA ""C"". CHANGES INCLUDE INTERCONNECTING PV BATTERY BACK UP TO THE MAIN SERVICE. REPLACING 100A PANELBOARD WITH AN ATS PANELBOARD AND INSTALLING A 25A ATS BREAKER.-Portion of the permit fee is paid under 17041-10000-44638.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4371	15041-10000-07856	362 E 1ST ST	90012	14	129A215    54	5161017033	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.04913	-118.23932	IN AN EXISTING RESTAURANR,INSTALLING 16 EA RESTROOMS AND SUSHI BAR ; OUTSIDE INSTALLATION OF 5EA WALL SCONES.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4372	19041-10000-47563	1545 W WILSHIRE BLVD 7th-Floor	90017	1	132A205   202	5142027036	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.05543	-118.26977	ENERGY PLAN CHECK ONLY, AREA OF SCOPE (1340)SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4373	15041-10000-06942	5510 S LINCOLN BLVD 3RD FLR	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	33.97299	-118.43051	TI TO AN EXISTING COMMERCIAL BUILDING.  REPLACING FIXTURES TO LED USING EXISTING CIRCUITS AND PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE PERFORMED IN THE THIRD FLOOR. TOTAL SQUARE FOOTAGE 2300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4374	13041-10001-27658	20721 W MARILLA ST	91311	12	201B109   154	2748004040	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.24819	-118.58497	Expedited plan check per applicant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4375	11041-10000-27511	333 S HOPE ST 23rd fl	90007	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	PIN	34.05338925	-118.25347338	Plan check is for Title 24Energy and 1 Emergency ckt on the 23rd floor. Permit for new branch circuits and equipment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4376	14041-10000-08511	7315 N FIGUEROA ST	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.13628	-118.18852	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT WELLS FARGO BANK. ALL OUTDOOR LIGHTING IS FOR ATM ILLUMINATION ONLY. BUILDING PERMIT APPLICATION#: 14016-10000-06007	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4377	13041-20000-15379	1129 S GRAMERCY DR PV-1	90019	10	129B193   780	5081029015	R1-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.05002	-118.31233	PV-1. 1.296kW AC microinverters added to existing 4000kW AC supplied by PV.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4378	15041-20000-23958	11700 N AVENIDA DEL SOL	91326	12	216B121   541	2872006034	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.28531	-118.54787	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (31) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4379	12041-10004-17970	380 WORLD WAY 5TH FL	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	REVISED PLNS TO SHOW  ADDITION OF XFMR AND SUB-PANEL34-C TO PANEL 2H-C7; RELOCATE SOME LOADSTHE EXISTING AND NEW 5TH FLOOR OF THE TOM BRABLY TERMINAL  AT  LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4380	11041-10000-07839	8039 S VERMONT AVE	90044	8	099B197   966	6033021018	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	33.96567	-118.292	NEW FIRE ALARM. 111 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4381	15041-20001-10155	19333 W BUSINESS CENTER DR	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM			PC Approved	03/06/2017 12:00:00 AM	ADDRESS	34.23134	-118.55494	03/06/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta F1. As noted, feeder conduit type has changed to PVC.*****Previous Work Description*****Power plan check for a new dialysis clinic. Project scope is a new 800-amp service, and includes the installation of (1) 800-amp MSB, (4) 200-amp panels, (1) 225-amp, and associates loads. I-2.1 occupancy areas exempt from Title-24, rest of building is not. Project is OSHPD-3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4382	14041-20000-30316	10700 N ARLETA AVE	91345	7	207B149   403	2617008025	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.26467	-118.44887	PV1. ROOF MOUNTED SOLAR SYSTEM. TRANSFORMERLESS CENTRAL INVERTER. SYSTEM SIZE: 5 KW AC.(1) PVI-5000 INVERTER(20)SOLARWORLD 250W	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4383	12041-10001-03136	3555 E WHITTIER BLVD 1-60	90023	14	121-5A227 207	5188005017	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Apartment			10/02/2012 12:00:00 AM			PC Approved	10/02/2012 12:00:00 AM	ADDRESS	34.02612	-118.19678	CHANGE TO PERMITTED SET OF PLANS- MAIN SWBD WAS LOCATED IN AN ALCOVE  AND DWP REQUIRED THAT IT BE REMOVED OUTSIDE NEAR IT WAS FIRST PERMITTED. SWBD SHALL BE SUITABLE FOR ITS LOCATION4-story, 60-unit type V-A family apartments over single level of Type-I-A Basement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4384	17041-20003-21308	5950 N LAUREL CANYON BLVD	91607	2	177B165   769	2340005037	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Issued	08/10/2018 12:00:00 AM	ADDRESS	34.17861	-118.39631	08-10-2018 Changes to an approved set of plans, changes include combined output of inverters to single disconnecting means and add performance meter; update system size: 51.648KW AC CEC.  All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4385	16041-10000-40316	5627 N SEPULVEDA BLVD	91411	4	174B145   396	2243002008	C2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.17316	-118.46646	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 52125 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4386	14041-20000-25501	1555 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			Reviewed by Supervisor	09/26/2014 12:00:00 AM	ADDRESS	34.09923	-118.32707	TI TO RESTAURANT. 800 DEGREES PIZZA. PLAN CHECK FOR POWER AND ENERGY. NEW 600A RATED EQUIPMENT AND TRANSFORMER AND SUBPANELS. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4387	19041-20000-09375	21340 W DEVONSHIRE ST	91311	12	204B105   323	2747011061	QC4-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Issued	03/29/2019 12:00:00 AM	ADDRESS	34.25707	-118.59648	Installation of a new addressable fire alarm system in two existing hotel buildings.  (237) devices with FACP, (5) RPS and annunciator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4388	17041-10000-06222	938 S HEMLOCK ST	90021	14	123A213   239	5130002014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.03038	-118.24415	T-24, PC FOR ENERGY ONLY. TI TO AN EXISITNG WAREHOUSE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4028 SQ. FT. B#17016-30000-04120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4389	13041-20000-21016	4591 N DE CELIS PL	91436	5	168B137   642	2284009042	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.15411	-118.49356	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 13.08 KW. 40 MODULES AND 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4390	10041-10000-22579	10250 W SANTA MONICA BLVD # 616	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Finaled	06/14/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	NEW INTERIOR TENANT IMPROVEMENTOF AN EXISTING STORE TO INCLUDE NEW ELECTRICAL THROUGH OUT PANELS AND LIGHTING AND RECEPTACLE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4391	19041-10001-04568	767 S ALAMEDA ST 4TH FL	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	CHANGES TO AN APPROVED SET. T-24 REVISION TO SUITE 470 ON 4TH FLOOR. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROL. TOTAL AFFECTED AREA IS 2441 SQ.FT Original Scope: ((TI TO AN EXISTING COMMERCIAL BUILDING 6 STORY BUILDING'S 4TH FLOOR, CHANGE TO BUILDING LAYOUT ON 4TH FLOOR, SCOPE OF WORK (12) 225A PANELS, (8) 100A PANELS, (2) 75 KVA TRANSFORMERS, AND (8) 45 KVA TRANSFORMERS, INCLUDES T24, TOTAL SQUARE FOOTAGE = 50,971NOTE: MODIFICATION HAS BEEN FILED FOR EXISTING PEAK DEMAND READING PER ARTICLE 220.87.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4392	09041-10004-19509	7660 W SUNSET BLVD	90046	4	147B177  1009	5550030001	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM			PC Approved	11/12/2010 12:00:00 AM	ADDRESS	34.09787	-118.3566	"REVISIONS TO APPROVED SET OF PLANS  -  DELTA 6 & DALTA 9 - REDUCED LOAD ON PANEL ""B""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4393	14041-20000-27913	1000 W WILSHIRE BLVD Ste. 1650	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.05085	-118.26078	TI to (E) commercial office space on the 16th floor.  Plan check for energy.  Permit already obtained under 14041-90000-24722.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4394	17041-10000-41186	14415 W DYER ST	91342	7	222B149  1015	2508021052	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Issued	11/14/2017 12:00:00 AM	ADDRESS	34.30167	-118.44681	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE 7.6KVA, CONSISTING OF CENTRAL INVERTER - SOLAR EDGE SE7600, AND 25 MODULES WITH P320 POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4395	15041-10000-21545	6115 W SUNSET BLVD BUSINESS-BLDG	90028	13	147A189    24	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Public Safety Only			07/08/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Expired	08/22/2018 12:00:00 AM	ADDRESS	34.09819	-118.32261	"NEW FIRE WARNING SYSTEM AT THE ""BUSINESS""BUILDINGNOTE- FA PLANS FOR THIS BUILDING WERE PERMITTED ON 14041-10000-03142 AND INCLUDED THE ""RADIO"" BUILDING AND AN ADDRESS 6112 W SUNSET. CLIENT WANTS A SEPARATE SET OF PLANS AND PCIS # FOR THIS BUILDING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4396	14041-20001-34547	3513 W SUNSET BLVD	90026	13	144A203   174	5429024002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.08921	-118.27641	01/21/2015 - Modification to approved set. Remove two fixtures pending test lab approval from plan so that project can be finaled (by inspector request). Changes made by applicant in Blue pen - delta changes dated 1-21-2015. Changes made directly on previously approved set. Stamps for this application shall be perpendicular to the original plan stamps.TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHTING TO EXISTING PANELS, ADDING NEW BRANCH CIRCUITS.  TOTAL SQUARE FOOTAGE PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4397	16041-20000-04338	1207 E ADAMS BLVD	90011	9	118-5A211 348	5119022003	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.01763	-118.25209	PV1.  Install 5.2 kW rooftop mounted PV system.  Applicant design set plans.  (1) SolarEdge SE5000A-US transformerless inverter with power optimizers and (20) Q.PRO BFR-G4-260 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4398	18041-10000-07937	15200 W SUNSET BLVD	90272	11	129B125   727	4412002023	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	34.04624	-118.52472	"Plan check for T24 only, ""Energy Reduction Project"" for Chase Bank. Replace indoor and outdoor luminaires to LED fixtures using existing circuits. Total area: 13,432 sq.ft indoor + 23,294 sq.ft outdoor"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4399	15041-10000-03142	1800 CENTURY PARK EAST 5th Floor	90067										Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM			PC Approved	02/03/2015 12:00:00 AM				Energy plan check for replacing light fixture  at the corridor in an office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4400	19041-10000-18334	720 W 107TH ST	90044	8	090A199   326	6061009012	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Expired	10/12/2023 12:00:00 AM	ADDRESS	33.93897	-118.28778	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 16 MODULES (QCELL 285) , 12 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 4.56KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4401	17041-20001-43270	1475 S BEVERLY DR 1-18	90035	5	129B165   154	4306009031	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/27/2017 12:00:00 AM	ADDRESS	34.05296	-118.39563	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4402	15041-10000-41006	6080 W CENTER DR SUITE 800	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	33.97713	-118.39172	PLAN CHECK FOR ENERGY ONLY FOR EXISTING COMMERCIAL BUILDING. SCOPE OF WORK ON CORRIDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4403	15041-10000-01345	2433 E HUNTER ST	90021	14	121-5A217 142	5168031015	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	34.02772	-118.22874	SERVICE UPGRADE TO AN EXISITNG BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4404	19041-20000-39696	12823 W VENICE BLVD	90066	11	111B153   716	4245017001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.0001	-118.44126	T24 PLAN CHECK FOR EXISTING COMMERCIAL LOW RISE. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 102 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4405	16041-20000-30716	1441 S VETERAN AVE 1-111	90024	5	129B153   139	4324013032	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			08/29/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Issued	10/06/2016 12:00:00 AM	ADDRESS	34.05268	-118.44373	Plan check for power only. Service upgrade from 600A to 800A. Reconnect existing 1Ph 3W 600 service equipment to new 3Ph 4W 800 service equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4406	15041-20000-24799	2508 N ARMSTRONG AVE	90039	4	148-5A207  72	5439016010	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.10206	-118.26212	Installation of new roof mounted solar PV array.  Total system size  = 1.25 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4407	14041-20000-08405	326 E 65TH ST	90003	9	105B205  1221	6011013033	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	33.98051	-118.26852	PV1.  Install 1.50 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.  Enphase M215-60-2LL.  6 modules: Canadian Solar CS6P-250P	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4408	15041-20002-02260	5700 W SANTA MONICA BLVD	90038	13	144B189   691	5536017034	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.0906	-118.31379	10.8.2015 - Plan check for changes to approved set. Remove 6 existing panels and install 6 new panels in  place of same amperage and voltage class, but with fully rated 42kAIC withstand rating. Existing breakers in panels to be changed out to match manufacturer and AIC rating of new panels.[Plan check for power only.  Title-24 has already been approved on master application.  Service upgrade to 1200 A with new distribution equipment.]*****Previous work description*****Plan check for energy only. First time tenant (7/11). New lighting including emergency. Total sqft. 2,260.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4409	15041-10000-15224	844 W 32ND ST	90007	9	121-5A201   6	5123008021	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.02521	-118.28335	Energy plan check for a church, outdoor only.  Scope includes facade lightings for the exterior of the building and (2) light pole for the hardscape area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4410	16041-10000-07723	5227 N VINCENT AVE	90041	14	163-5A225 178	5669018010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.14226	-118.20245	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (34) MODULES, (1)3.0 KW INVERTER AND (1) 7KW INVERTER. TOTAL SYSTEM SIZE IS 10KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4411	17041-10000-42334	1120 W 6TH ST	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.05418	-118.26297	PC FOR FIRE ALARM IN NEW GROCERY STORE TENANT. ADDING NEW DEVICES TO TENANT SPACE TO AN EXISITG BUILDING FIRE ALARM. TOTAL NEW DEVICE COUNT 33 WITH 1 BATTERY BOOSTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4412	13041-20000-14229	2701 S BROADWAY	90007	9	120A205    69	5122002016	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	ADDRESS	34.02427	-118.27073	Change to lighting and receptacles to an existing retail store.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4413	13041-10001-33099	23229 W CALIFA ST	91367	3	177B093   855	2041006005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.17725	-118.63332	Expedited RSES plan check per applicant request.[][][]PV1, Install 6.25 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter(s):Solaredge SE6000A-US. 25 modules TRINA SOLAR TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4414	09041-10002-03426	13550 W PAXTON ST	91331		210B157   162	2535002014	M3-1		Arleta - Pacoima	Pacoima			Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM			PC Approved	02/12/2010 12:00:00 AM	ADDRESS	34.27276	-118.42714	Supplemental application. Revision to approved plans for refrigeration boxes and power panel. New Costco warehouse.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4415	15041-20000-19704	10201 N GAVIOTA AVE	91343	12	204B141   551	2669008005	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.25567	-118.48279	Plan check for PV roof mounted system. Total system size: 5.4kW system and 24 modules and 24 microinveters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4416	18041-10000-17068	1420 N LAUREL WAY	90210	5	147B161   224	4355015051	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	11/10/2018 12:00:00 AM	ADDRESS	34.09776	-118.41779	0$ permit fees due to senate billl 1222NEW 16.8KW ROOF MOUNTER PV SYSTEM WITH 46 PV MODULES ON A SINGLE FAMLY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4417	19041-10000-06568	2515 W BEVERLY BLVD	90057	13	136-5A203 121	5157009027	C2-1	Central	Westlake	Echo Park		2085.01	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.06907	-118.27536	Plan check for a methane detecting system with (48) devices and (3) control panels located in a commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4418	19041-10001-16109	5815 W 96TH ST MSF	90045	11	093B169   162	4125023931	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	33.94956	-118.38359	THIS SUPPLEMENT REVIEW IS FOR THE MSF 02 SET OF PLANS THAT PROVIDES ADDITIONAL INFORMATION FOR THE CONDUIT/DUCTBANK INSTALLATION BETWEEN THE DWP'S VISTA SWITCHES AND THE MSF BUILDING ( 19041-10000-16109)(((((((((Medium Voltage power distribution system for LAX APM project.This System will distribute power from utility source to CTA West Station, ITF West Station, CTA Center Station, ITF West Station and traction powered substation at ITF East Station with two 12.4KV Feeders.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4419	16041-20002-26321	7654 N TAMPA AVE	91335	3	186B117    46	2104012038	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM			Reviewed by Supervisor	03/03/2017 12:00:00 AM	ADDRESS	34.20985	-118.55333	02/15/2017 Changes to an approved set of plans. There has been the addition of (2) transformers and (2) subpanels to the system.*****Previous Work Description*****PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222Plan check for PV2 roof mounted system. System size: 70kW with 2 inverters(15kW), 2 inverter(20kW) with 202 modules connected to MSP1 and MSP2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4420	13041-10000-11867	315 W 9TH ST 200	90014	14	127-5A209 141	5144018049	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	PIN	34.04341508	-118.25728547	PC FOR ENERGY only. TI TO EXISTING building (OFFICEs).  GENERATOR. HISTORIC building requires clearance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4421	10041-30000-00701	930 S ROBERTSON BLVD	90035	5	132B169   183	4333011015	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM			PC Info Complete	01/14/2010 12:00:00 AM	ADDRESS	34.0599	-118.38342	TI - coffee shop - Permit is for new ckts on existing panels.  P/C is for Energy and Emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4422	16041-20000-31446	12647 N GLENOAKS BLVD	91342	7	219B153    17	2508027013	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.2999	-118.44013	Plan check for Title 24 only. Project site is an existing tenant space. Project scope is a tenant improvement. Total lighting area = 1,559 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4423	18041-10000-09040	6701 N DARBY AVE	91335	3	180B125   188	2125014030	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.19237	-118.53362	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4424	16041-10001-14779	4905 W HOLLYWOOD BLVD	90027	4	147B197   191	5589038036	C2-1D	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.10198	-118.29645	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED. CHANGE TO POWER AND LIGHTING PLAN LAYOUTS. PROVIDED METHANE PULL SECTION ON SINGLE LINE. UPDATED PANELS, AND RELATED NOTES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4425	17041-20001-07411	830 S OLIVE ST	90014	14	127-5A209  95	5144018026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.0443	-118.25741	Removal of occupant sensing controls for receptacles in units. (((TI to an existing three story commercial building.  Adding new lighting and new controls to existing panels. Plan check for energy only.  Total square footage - 3,110 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4426	19041-10000-35868	4211 N EAGLE ROCK BLVD	90065	14	156A219   107	5473024024	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	10/23/2023 12:00:00 AM	ADDRESS	34.12229	-118.22486	T-24 PLAN CHECK FOR A TI TO A RETAIL STORE (TARGET).  SCOPE INCLUDES NEW LIGHTING and equipment with a total lighting area of 3,156-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4427	19041-10000-00570	6333 W 3RD ST 614	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM			PC Approved	01/07/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	PLAN CHECK FOR TITLE 24 ONLY TENANT IMPROVMENT TO COFFEE SHOP SCOPE INCLUDES 215 SQFT. BLD# 18016-10000-41286	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4428	16041-10001-42999	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	REVISIONS TO APPROVED SET OF PLANS- MSVG ROTATED 90 DEGREES TO ENABLE ROUTING OF DUCT BANKS;  STEP DOWN TRANSFORMER ( 5KV TO 277/477V ) FOR  DISTRIBUTION BOARD SUPPLYING EXISTING 277/480V LOADS PLAN CHECK ONLY(((((((FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES ADDING  NEW SUBSTATIONS, ONE NEW GENERATOR AND  NEW ELECTRICAL EQUIPMENT  FOR THE PHASE-2 OF LOS ANGELES MEMORIAL COLISEUM. TOTAL AFFECTED AREA IS 131631 SQ. FT. REFERENCE APPLICATION: 17041-10000-17773                                                     B#16016-10000-27246	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4429	14041-10000-07193	101 S LA BREA AVE	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.07338	-118.34425	TENANT IMPROVEMENT IN EXISTING COMMERCIAL SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4430	14041-20001-10656	23900 W STAGG ST	91304	12	189B089   447	2027040033	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			PC Approved	10/03/2014 12:00:00 AM	ADDRESS	34.21056	-118.64943	Fee is $0 due to senate bill solar cap.  Changes made to approved set.  Inverters are now SolarEdge SE-3800A. permit issued on master application.PV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL TRANSFORMERLESS INVERTER STANDARD PLAN. SYSTEM SIZE: 9.25 KW DC.(37) CANADIAN SOLAR CSP 250(2) POWER ONE  PVI 3.6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4431	13041-10001-32229	2030 N CUMMINGS DR	90027	4	151-5A195 179	5589009019	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.10803	-118.30192	Expedited RSES plan check per applicant request.(((PV1, Install 11.76 kW DC roof-mounted solar array for a single family dweling, interconnect with service panel. Transformered inverter: Fronius IG Plus V 10.0. 48 modules TRINA SOLAR TSM-250PA05.18.)))New application refer to app# 13041-10000-10556 per applicant request has issued.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4432	16041-20001-07521	4665 W MELROSE AVE	90029	13	141B193   563	5535036025	C2-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	34.08368	-118.30206	05-24-16 Changes to an approved set of  plans. Changes include  feeder size changes for (1) 500kcmil to (2) 3/0, Bussed to wired, addition of fused disconnect and 100A. Changes apply to delta 2 only. PLANCHECK FOR POWER. SERVICE UPGRADE TO 800 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4433	16041-10000-11662	10880 W WILSHIRE BLVD ste. 2250	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.05885	-118.44283	TI on (E) office build. on Suite #2250. Install new lights and control receptacles. PC for T-24 only. Total area: 1,644 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4434	19041-20001-15666	24430 W HATTERAS ST	91367	3	174B089   382	2046009011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	ADDRESS	34.17291	-118.65698	Expedited plan check fee.PV1.  Install 17.16 kW DC / 14.58 kW AC-CEC roof mounted grid tied PV system.  (52) modules with (2) 7.6 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4435	18041-10000-11897	950 W FRANCISCO ST	90502	15	057B197    66	7351034068	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	33.84971	-118.29198	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4436	14041-20000-18702	9058 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.23458	-118.55336	Plan check for energy only. TI for existing commercial building. New lighting (incl. emergency) in 2,067sqft Sylvan learning center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4437	19041-20000-32466	9301 N TAMPA AVE Space 171	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE 24 ONLY. TOTAL AFFECTED AREA 1048 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4438	17041-10000-45766	1015 W 68TH ST	90044	8	102B197   422	6014020024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	33.97796	-118.29254	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 5.04KWACSCOPE INCLUDES 21 MOUDULES WITH MICRO INVERTERS AND NEW LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4439	13041-10000-06110	1957 S WELLINGTON ROAD	90016	10	126B185  1174	5061004009	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.03825	-118.33502	photovoltaic system for single family dwelling. total system size 6.24 kw. 26 PANELS. CENTRAL INVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4440	19041-20001-36925	11115 W VANOWEN ST	91605	2	183B173   186	2319005018	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.19409	-118.37253	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGES MADE TO ALL PAGES EXCEPT THE SINGLE LINE. RELOCATION OF ROOMS AND CHANGES MADE TO ROOMS, PANEL SCHEDULE, AND T24 SHEETS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4441	13041-20002-15016	8445 N RESEDA BLVD	91324	12	192B125   359	2785018060	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.22408	-118.5363	Lighting in bike storage room added to Title 24 calculations.  (((changes to approved se of plans. 3 new transformers to supply 208 voltage for dryer units. no change in load. just a change in voltage class and minor load redistribution. reverify effected home runs.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4442	13041-10000-31282	22100 W INDEPENDENCIA ST	91364	3	168B101  1005	2076022060	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.15268	-118.60797	PV1, ROOF-MOUNTED 5.4KW DC PHOTOVOLTAIC SYSTEM INSTALLATION WITH TRANSFORMERLESS, WITH (20) MODULES (SOLARWORD SW270) AND  POWER-ONE PVI-5000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4443	16041-10000-40875	4091 S REDWOOD AVE	90292	11	108B153   893	4230006032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	PIN	33.99096225	-118.44116852	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE WITHIN AN APARTMENT BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES OFFICES 101 AND 102. TOTAL AFFECTED AREA IS 2587 SQ. FT.  B#13010-10009-04343	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4444	18041-20000-07684	1482 S SHERBOURNE DR	90035	5	129B169   450	4303019024	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			03/02/2018 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	08/20/2021 12:00:00 AM	ADDRESS	34.05159	-118.37971	Plan check for power and energy. Project site is a new 4-story, 10-unit apartment building. Total lighting area = 13,526 sq. ft.Note: Building application has been generated under 17010-20000-04621	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4445	17041-10001-18554	232 E 2ND ST Suite G-1-240	90012	14	129A213    28	5161024034	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.0495	-118.24258	08/11/17Changes to an approved set of plans. All changes are clouded under delta 2. Changes include removing/relocating HVAC equipment on the roof and floor plans, and revising panel schedules.Note: Permit is paid under PCIS#17041-10000-18554((((((((Plan check for power and Title 24.  First time T.I. of bank space including new ATMs.  Total area = 1,859 sq. ft.       Building permit #17016-10000-14730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4446	14041-10000-09844	2800 E 11TH ST	90023	14	120A221   138	5169007002	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Issued	04/15/2014 12:00:00 AM	ADDRESS	34.02241	-118.21816	New 600 amps service, over head 120/240 3 phase 4 wire.  and one 200 amps panel, motors comperessor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4447	19041-20000-16942	13211 W LUMINA WAY	91401	2	180B157  1175	2326025033	(T)(Q)RAS3-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Re-Activate Permit	01/06/2020 12:00:00 AM	ADDRESS	34.18703	-118.42075	new 600 amp service for sfd.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4448	16041-10000-06460	1 WORLD WAY	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	33.94469	-118.39817	PC FOR POWER, 2 NEW DISTRIBUTION PANELS FOR 13 CHARGING STATION AT LA X. TOTAL CONNECTED LOAD > 400AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4449	14041-10000-15863	1100 S SAN PEDRO ST STE#BO6	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.03515	-118.25194	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 825 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4450	14041-20000-17104	8124 W 3RD ST	90048	5	138B173   960	5511029032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM			PC Info Complete	06/25/2014 12:00:00 AM	ADDRESS	34.0721	-118.36676	plan check for title 24 energy only.  Exisiting commercial building two stories.  Replacing fixtures on the second floor only.  No new loads all circuits are existing. Emergency and emergemcy egress lighting to be provided at a later time on a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4451	14041-10000-00434	14734 W HUBBARD AVE	91342	7	216B149   457	2612013002	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	PIN	34.28792553	-118.4523209	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 3.5 KW DC.(14) ENPHASE EN-M215 MICROINVERTER(14) SOLARWORLD 250W MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4452	12041-10003-09171	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.0754	-118.38272	CHANGES TO APPROVED (delta 11 for circle note 4): RESTROOM emergency lights are unit equipment, update load calcs, and general notes regarding multiwire branch circuits, and equipment nameplate coordination. affected sheets E2L1 and E4.1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4453	18041-20000-18566	6800 N VARIEL AVE	91303	3	183B105   995	2138023045	(WC)RIVER-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1349.03	Electrical	Electrical	Apartment			05/18/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.19402	-118.59264	Plan check for a fire alarm system for new 5-story, 18-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (126) devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4454	16041-20000-29441	4910 N VAN NUYS BLVD	91403	4	169-5A151  69	2248007140	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM			Reviewed by Supervisor	09/12/2016 12:00:00 AM	ADDRESS	34.15985	-118.4485	Plan check for power and energy. TI to existing dental office. New lighting and power. 1,670sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4455	19041-20000-17259	13801 W VENTURA BLVD	91423	4	165B153   543	2271017005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.14852	-118.43319	T24 ONLY PLAN CHECK. TI TO EXISTING LOW RISE COMMERCIAL BUILDING. LIGHTS AND OUTLETS ONLY ON EXISTING BRANCH CIRCUITS. TOTAL SQUARE FOOTAGE = 1204SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4456	14041-10000-15632	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016021	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.08758	-118.34425	PLAN CHECK FOR NEW SPROUTS. SERVICE SIZE 2000AMPS, PART OF EXISTING DISTRIBUTION SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4457	18041-30000-07178	2049 S CENTURY PARK EAST 18th Floor-rr	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for title 24 only existing restroom men and womem in 1st Floor restroom Total area: 410 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4458	18041-10000-15176	2465 E 16TH ST	90021	14	118-5A217 293	5168010012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.01994	-118.22759	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4459	14041-10000-27524	4996 W MELROSE AVE	90004	13	141B193   606	5521001029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	PIN	34.08329075	-118.30883804	PV2, INSTALL 165 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 3-STORIES COMMERCIAL BUILDING. 2 NEW 600A MAIN SERVICE PANEL .(660) MODULES: REC PEAK ENERGY SERIES REC250PE (11) INVERTERS: SOLECTRIA 14TLNote: Final fees are $0 due to senate bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4460	13041-10000-33305	7532 W FOOTHILL BLVD	91042	7	204A197   367	2558028048	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	11/27/2013 12:00:00 AM	ADDRESS	34.25344	-118.29668	PLAN CHECK FOR T24, ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLOURESCENT FIXTURES. AREA 3612 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4461	18041-10000-37011	5803 N FIGUEROA ST	90042	1	151-5A229 122	5492012025	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.11032	-118.19182	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4462	14041-10000-35066	404 S FIGUEROA ST	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM			PC Approved	12/18/2014 12:00:00 AM	ADDRESS	34.05326	-118.25596	Title 24 plan check only.  Total area = 5,599 sq. ft.T.I. to existing office space to create new meeting rooms.  Installation of lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4463	12041-10000-27109	15505 W ROSCOE BLVD	91343	7	192B145   364	2654028009	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.06	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.22156	-118.47097	PV2 COMMERCIAL SOLAR INSTALLATION. 742KW SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4464	17041-20000-10131	15220 W ANTELO PL	90077	5	159B145   589	4378005008	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.12922	-118.46269	Install 7.93 kW roof mounted grid-tied PV system.  (26) modules with (1) 6kW rated central inverter with power optimizers.  Connecting to (E) 8kW rated PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4465	19041-10000-39342	5801 W PICO BLVD	90019	10	129B177   431	5086015030	C4-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			09/30/2019 12:00:00 AM	01/25/2023 12:00:00 AM		Permit Finaled	03/02/2023 12:00:00 AM	ADDRESS	34.05129	-118.36466	pc for methane detection system. system consists of 1 FACP and 17 devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4466	14041-20000-33533	6109 N MANTON AVE	91367	3	177B093   524	2035005013	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.18092	-118.64097	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5.805kW. Ungrounded system.27 EnPhase M215-IG microinverters with 27  250W pv modules across two strings (17+10).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4467	17041-30000-19009	1713 S WESTERN AVE A & B	90006	10	126B193  1421	5073012034	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.04227	-118.30925	Plan check for Title 24 only in existing space Newly connected load less than 400A. Total area: 5023 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4468	18041-20000-10154	10917 N CARTWRIGHT DR	91311	12	210B113   251	2708029010	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.26912	-118.56654	PV1.  Install 5.76 kW roof mounted grid tied PV system.  (18) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4469	15041-20000-29727	15087 W LA MESA ST	91342	7	228B145   369	2502005013	RA-1	North Valley	Sylmar			1064.06	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	10/17/2015 12:00:00 AM	ADDRESS	34.31935	-118.4613	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4470	10041-10000-25641	19836 W VENTURA BLVD	91364	3	174B113   413	2164011023	(T)(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1394.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Expired	02/05/2013 12:00:00 AM	ADDRESS	34.17212	-118.56536	INSTALLATION OF A 800A 3P TRANFER SWITCH TO SUPPLY NON LEGALLY REQUIRED LOADS FROM A MOBILE GENERATOR WHICH IS NOT PART OF THIS REVIEW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4471	13041-20000-21446	8828 N VALJEAN AVE	91343	12	195B137   540	2688013025	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Expired	09/11/2015 12:00:00 AM	ADDRESS	34.23101	-118.48717	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0 KW. 24 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4472	11041-20000-00746	18411 W VICTORY BLVD	91335	3	180B125   625	2124001902	OS-1XL	South Valley	Reseda - West Van Nuys	Reseda		1329.00	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	07/30/2012 12:00:00 AM	ADDRESS	34.18676	-118.53453	pool equipment and lighting complete plan check energy was done under separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4473	19041-10001-22393	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM			PC Approved	07/03/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	(Supplement to PV for expedite) pc for commercial pv. system size is 7.575kw. 15 module (LG NEON R model) with 15 optimizers (Solaredge P505). 1 inverter (Solaredge SE10KUS).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4474	16041-20001-12717	5340 N CORBIN AVE	91356	3	171B117   100	2164019026	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.16783	-118.56254	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4475	14041-20001-11218	15246 W OLIVE LN	91342	7	228B145   832	2501016***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			Plans on Hold	05/14/2014 12:00:00 AM	PIN	34.31772164	-118.46527294	Expedite per customer requestPV1. 2.25kw roof-mounted system with power optimizers, (9) canadian solar modules and (1) Solaredge SE3000A-US-ZB-U inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4476	14041-10000-15689	13615 W DEBBY ST	91401	2	177B157   241	2330011002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.18401	-118.42976	ROOFTOP SOLAR PV SYSTEM INSTALLATION.  TOTAL SYSTEM SIZE = 6.4 kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4477	19041-10000-29346	10 W UNIVERSAL CITY PZ	91608	4	162B177   352	2424044020		North Valley				1437.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Issued	09/27/2019 12:00:00 AM				INSTALLING TWO NEW 400 AMP DISTRIBUTION PANELS AND 9 SUBPANELS FEED FROM 2 @ 300KVA UPS FOR THE IT EQUIPMENTIN A HIGH RISE BUILDING. TOTAL NEW ADDED LOAD > 400AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4478	18041-10000-33123	12444 W VENICE BLVD	90066	11	111B153   326	4235013027	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.0028	-118.43476	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4479	11041-10000-16038	1741 N CHEROKEE AVE	90028	13	148-5A185  32	5547009014	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	01/09/2012 12:00:00 AM	ADDRESS	34.10281	-118.33488	TI AND NEW GARAGE FOR AN OFFICE BUILDING.  REQUESTED PLAN CHECK FOR ENERGY AND POWER PER APPLICANT.  PARTIAL PERMIT WAS ISSUEDON SEPERATE APPLICATION 11041-10000-13179.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4480	19041-10000-44483	1387 W 35TH ST	90007	8	120B197   682	5040003024	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.02471	-118.29999	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4481	16041-10000-27488	8500 W BEVERLY BLVD #613	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Info Complete	08/24/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	"Plan check for T-24 only.  TI  at an (E) retail  space ""Steve Madden"".  Newly connected load < 400A.  Total affected area: 1,930 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4482	12041-10002-21521	685 N SPRING ST	90012	1	133-5A215 166	5408014018	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM			PC Approved	01/25/2016 12:00:00 AM	PIN	34.05979754	-118.23833413	**Supplemental PC: Delta 4: changes on light fixtures A & B to use LED, revise quantity of fixtures.    Permit under 12041-10001-21521***NOTE CHANGES ON DELTA 1. SCOPE INCLUDES CHANGE OF FIXTURES. ****((CHANGE OF USE OF RETAIL SPACE TO DINING AREA OF EXISTING RESTAURANT. EXISTING RESTAURANT OCCUPIES SPACE # H  AND THIS ADDITION OCUPPIES # E,F,AND G.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4483	11041-10000-11987	3620 S MCCLINTOCK AVE BLDG 124	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM			PC Approved	06/10/2011 12:00:00 AM	ADDRESS	34.0213	-118.28935	TI TO AN EXISTING AUDITORIUM ON USC CAMPUS.  PLAN CHECK IS FOR ENERGY ONLY.  Over the counter PLAN CHECK ONLY.  SEELEY G. MUDD BUILDING LECTURE HALL -- BUILDING # 124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4484	12041-10000-13236	3625 S GRAND AVE	90007	9	118-5A203 223	5122023027	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	12/04/2012 12:00:00 AM	ADDRESS	34.01785	-118.2778	New Fire alarm system with 334 devices for an existing storage facilty.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4485	13041-10000-25289	8521 N HASKELL AVE	91343	12	192B141   199	2673010028	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.22525	-118.4766	"""Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.""PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 13KW DC ON NON-STANDARD PLAN IN A 2-STORY HOME. LOAD CENTER & COMBINER BOX IS USED. (52) TRINA SOLAR #TSM-250(2) POWER-ONE  #PVI-5000-OUTD"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4486	17041-10000-43536	16353 W BARNESTON ST	91344	12	216B137   498	2605011032	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.28519	-118.48824	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE 5.18KWdc / 3.80KWac. (14)MODULES-SILFAB SLG-M370(14)OPTIMIZERS-SOLAREDGE P370(1)INVERTER-SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4487	15041-20000-09405	6636 W SELMA AVE	90028	13	148-5A185 380	5547019028	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.09959	-118.33446	Plan check for power and Title-24 (energy).  Total area = 5,760 sq. ft. (indoor) and 5,378 sq. ft. (outdoor)Service upgrade to existing church space.  New main service panel and four new subpanels.  Changes to lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4488	18041-10000-01684	694 S OXFORD AVE	90005	10	132B193   240	5093006900	CR-2, P-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.06001	-118.30763	PC for T24 only for new lighting for media lab TI. Installing new lights, receptacles and new panel. Total area is 2370sqft. B#16016-10000-30872.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4489	12041-20000-09643	12411 W SHELDON ST	91352	6	195B165   204	2629019015	(T)(Q)C1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	05/25/2012 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	34.23261	-118.40328	New Building. Plan check for power and energy. Single commercial building. Retail. 9585 sqft outdoor, 717sqft (unit 4 only). Other units will be done with future TIs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4490	12041-20000-05922	12265 W VENTURA BLVD	91604	2	162B165   111	2367017016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			PC Approved	04/03/2012 12:00:00 AM	ADDRESS	34.14328	-118.40035	T.I. to existing building.  Install general/emergency light.  Plan check for energy only.Note: Permit issued under 12041-20000-05924	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4491	18041-10000-22665	3131 S HOOVER ST BLG 9C	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	34.02605	-118.28472	TI IN AN EXISTING COMMERCIAL AREA IN BUILDING 9C.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4492	14041-10000-29473	1642 S FEDERAL AVE 1-8	90025	11	126B149   283	4261013031	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			10/23/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.04365	-118.4529	New fire alarm system for 8 unit apartment.  60 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4493	14041-10000-17223	15140 W BLEDSOE ST	91342	7	222B145   103	2506002029	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.30714	-118.46302	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 6262 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4494	11041-10001-19354	15233 W LA CRUZ DR	90272	11	129B125   734	4412002016		West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	ADDRESS	34.04577	-118.52516	((((((((((((((((((((((( 8-2-12  Previousley approved set, additional 64 miro inverter, and a200 amps disconnect ,)))))))))))))))))) PHOTOVOLTAIC SYSTEM, ENPHASE MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4495	14041-10001-23980	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.14441	-118.39252	Changes to approved set, noted as Delta 2 and Delta 3 dated 03/16/16 on the plans: update light fixtures, T-24, rearrange branch circuits, adding 2 motor loads. <<NEW 800AMP SERVICE FOR 5 STORY TYPE2A OFFICE AND GARAGE BUILDING.(2 STORIES PARKING, 3 STORIES OFFICES.PLAN CHECK FOR POWER AND ENERGY.PLAN CHECK IN ACCORDANCE TO 2008 ENERGY EFFICIENCY STANDARDS DUE TO BUILDING SUBMITTAL.>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4496	13041-10000-23414	2950 N BEVERLY GLEN CIR	90077	5	156B153    17	4382030065	RE15-1VLD-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	ADDRESS	34.12777	-118.44363	PROPOSED NONSTRUCTURAL INT T.I. TO EX. RESTAURANT - 1,197SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4497	18041-10000-12579	13724 W VICTORY BLVD	91401	2	180B157   951	2239006030	P-1VL, [Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	ADDRESS	34.18639	-118.43217	FULL PC FOR A NEW 5 STORY MIXED USE BLDG - 67 UNIT APT  AND FUTURE RETAIL. SERVICE SIZE IS 2000A. 120/208, 3PH. SCOPE INCLUDES 11 TYPICAL UNITS. TOTAL SQ. FT. 233360.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4498	16041-30000-24482	1936 E 1ST ST	90033	14	129A221   303	5174016057	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM			PC Approved	07/28/2016 12:00:00 AM	ADDRESS	34.04587	-118.21637	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to a dialysis clinic. No work is being done in patient care areas. All work is being done within staff offices and training rooms. Total lighting area = 900 sq. ft.Note: Building application has been created under 16016-30000-15734	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4499	10041-20000-16664	21771 W VENTURA BLVD	91367	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	PIN	34.16926375	-118.60275102	PLAN CHECK -T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR TI CHANGE OF USE FROM TWO SEPERATE RETAIL/OFFICE TENANTS TO MASSAGE PARLOR. EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4500	14041-10000-05683	10244 N LANGMUIR AVE	91040	7	204B193   764	2559017008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.25558	-118.30865	PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(23) MODULES: CANADIAN SOLAR CS6P-250PX(1)TRANSFORMERLESS IN VERTER: SOLAREDGE SE6000A-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4501	14041-20000-03819	18638 W HART ST PV1	91335	3	183B121   555	2126019014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.19755	-118.54005	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH MAIN SERVICE PANEL. SYSTEM SIZED @ 18.25 kW DC, AND IS TRANSFORMERLESS, WITH (3) POWER ONE INVERTERS; PVI-6000-OUTD-US-A, PVI-5000-OUTD-US-A, PVI-5000-OUTD-US-A, (73) MODULES ET-P660250BB, (1) SUBPANEL.$0 permit fee due to senate bill 1222 from 2012))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4502	16041-10000-13497	526 E JEFFERSON BLVD	90011	9	117A207   116	5120022006	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.0157	-118.26649	New 1 story warehouse. PC for T24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4503	10041-10000-23416	500 W 7TH ST # 2	90014	9	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	12/22/2010 12:00:00 AM	ADDRESS	34.04651	-118.25582	CHANGE OF USE FROM RETAIL TO BEAUTY SALON (20' X 84').   INTERIOR REMODEL.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4504	10041-20000-22511	3101 S OVERLAND AVE Unit #C	90034	5	123B161   857	4254011039	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	05/18/2011 12:00:00 AM	ADDRESS	34.03044	-118.41627	"First time occupancy in unit #""C"".   Plan check is for power and energy"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4505	15041-10000-16140	4401 W SUNSET BLVD	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.09708	-118.28526	NEW FIRE ALARM SYSTEM, 2 CONTROL PANELS, 1 FIRE ALARM PANEL, AND 203 FIRE ALARM DEVICES .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4506	16041-10001-30410	737 S BROADWAY	90014	14	127-5A209  77	5144014030	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	34.04443	-118.25434	FULL PLAN CHECK FOR EXISTING BUILDING WITH NEW CONNECTED LOAD >400A - SCOPE INCLUDES INSTALLATION OF NEW (150KW)GENERATOR, TRANSFER SWITCH, AND (75HP)FIREPUMP, 20 CONDENSING UNITS, 13 NEW PANELS ANBD ELECTRICAL EQUIPMENT  TO EXISTING HIGHRISE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4507	14041-10000-15808	11054 N TAMBERLY LANE	91042	7	210B197   581	2552046016	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Expired	08/11/2016 12:00:00 AM	ADDRESS	34.2699	-118.29257	PV1, Install 6.885 KW DC roof-mounted solar array on a two-story house, interconnect with main service panel. Transformerless inverter. With optimizer.(27) Modules: Trina Solar # TSM-255pa05.18(1) Inverter: SOLAREDGE #SE6000A-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4508	16041-20000-40274	818 S BERENDO ST	90005	10	132B197   595	5094013022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.05708	-118.29399	$0 permit fee due to State Senate Bill SB 1222.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 30kW (6kW*5) ungrounded system. (110) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4509	12041-10002-12412	10511 W TUXFORD ST PV1	91352	7	198B177   189	2544022021	RE40-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM			PC Approved	11/08/2012 12:00:00 AM	ADDRESS	34.23564	-118.35979	"CHANGES TO THE APPROVED PLANS. REPLACE TWO DC DISCONNECTS WITH ONE SQUARE ""D"" DC DISCONNECT ON THE WALL ADJACENT TO THE INVERTERS.  This submittal is plan check only.  Permit is existing under 12041-10000-12412"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4510	18041-20002-06943	15708 W CHATSWORTH ST	91344	12	207B141   433	2661002002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.26445	-118.4744	Supplemental for changes to approved set. Changing location of main service panel, PV inveter, performance meter and AC disconnect. No changes in system size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4511	15041-20001-36502	1139 N ROBERTO LANE	90077	5	144B145    56	4377023045	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM			PC Approved	11/09/2015 12:00:00 AM	ADDRESS	34.09386	-118.45978	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.25 k Wac and consists of (41) modules, (41) micro-inverters, (1) combiner box, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4512	15041-10000-24716	7083 W HOLLYWOOD BLVD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.10173	-118.34439	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW OFFICE SPACES WITH (E) LIGHTING. TOTAL SQ. FT. 1266.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4513	14041-20000-09911	444 S FLOWER ST 11th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	Improvements to 11th floor corridors/restroom in commercial highrise office building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4514	12041-10001-28919	9525 N OWENSMOUTH AVE	91311	12	201B105   247	2746016032	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	34.24353	-118.60253	supplamental TO 12041-20000-28919. PC ONLY FOR RELOCATION OF DISTRIBUTION SECTION TO MAIN SWITCH GEAR,  New upgraded 3000 amp servicej, 34.5kv transformer, and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4515	19041-10000-05811	1403 N GARDNER ST	90046	4	147B177  1248	5550025902	[Q]PF-1XL	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.09638	-118.353	PLAN CHECK FOR NEW FIRE ALARM IN SINGLE STORY BUILDING. SCOPE INCLUDES 33 DEVICES AND 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4516	14041-20000-08056	1660 E 23RD ST	90011	9	117A213   113	5118021009	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Issued	03/26/2014 12:00:00 AM	ADDRESS	34.01588	-118.24434	"PLANCHECK FOR POWER.  REPLACE DAMAGED/VANDELIZED EXISTING 1200 AMP 3PHASE 4 WIRE SWITCHGEAR WITH NEW 800AMP 3 PHASE 4WIRE. ""ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4517	19041-10000-01091	3964 N EAGLE ROCK BLVD	90065	1	156A217   251	5460002036	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.1198	-118.22891	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4518	18041-20000-34268	10355 N CHRISTINE PL	91311	12	204B117    72	2708024019	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.25881	-118.56159	Plan check for a PV1 roof-mounted PV system. System size is 24.05 kWdc/20 kWac and consists of (2) inverters, (74) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4519	11041-20000-21006	13024 W SHERMAN WAY	91605	2	183B161    40	2327017040	C2-1VL	South Valley	North Hollywood - Valley Village			1234.20	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.20098	-118.41702	PLAN CHECK T24 ENERGY TO RETAIL/BAKERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4520	13041-10000-25478	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.05855	-118.23671	MEDIUM VOLTAGE GENERATOR HOOK UP WITH NEW TRANSFORMER STEPPED UP TO 12.47 KV. PRIMIARY AND SECONDARY LOAD INTERRUPTING SWITCHES. BUILDING IS EXISTING. 4 STORIES. (conduit only pulled on 10/28/2013 mt)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4521	15041-10000-37659	11755 W WILSHIRE BLVD 14TH FLR	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM			Corrections Issued	11/09/2015 12:00:00 AM	PIN	34.04869377	-118.46238681	TI, T-24 TO AN OFFICE SPACE IN THE 14TH FLOOR OF AN  (E) HIGH RISE BUILDING.  SCOPE OF WORK INCLUDES 3 NEW LIGHTING FIXTURES AND RECEPTACLES. TOTAL SQ.FT. 2155	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4522	18041-10000-43418	9060 W THRASHER AVE	90069	4	147B169   653	5560007006	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.0982	-118.38828	Permit fee is $0.00 due to Assembly Bill No. 1414NEW ROOFTOP SOLAR SYSTEM CONSIST OF 90 MODULES (SLG-M-370) , 90 OPTIMIZERS (SOLAREDGE P400) AND FOUR SINGLEPHASE INVERTERS (SOLAREDGE 7.6KW EACH).  SYSTEM SIZE IS 33.3KWdc and 30.4KWac. SCOPE INCLUDES 200A COMBINER BOX AND 400A SOLAR READY PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4523	19041-10000-30938	640 S SANTA FE AVE	90021	14	124-5A217  45	5164015022	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	08/30/2021 12:00:00 AM	ADDRESS	34.03662	-118.23012	Full plan check for commercial building, Scope of work includes new 2500 Amp, 480/277V service, panels, circuits and lighting and all associated equipment. Total sq. ft. 123,390	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4524	19041-10000-47312	16926 W DULCE YNEZ LANE	90272	11	129B121   854	4419018043	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.04672	-118.54983	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 24  (HANWHA DUO BLK-G5/SC315) MODULES,  1 (DELTA SOLIVIA 7.6TL) CENTRAL INVERTER, 1 TELSA POWERWALL, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 7.56KW DC & 7.60KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4525	17041-30000-11671	3739 S CRENSHAW BLVD D	90016	10	117B185  1308	5046024025	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.01924	-118.33559	Plan check for Titel 24 only in existing space. Total area: 1745 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4526	12041-20000-15447	2587 N LOMBARDY BLVD	90032	14	139-5A233 160	5216010029	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.07639	-118.17629	New roof mounted P.V. system with 2.34 KWdc.Note: Permit issued under 12041-20000-15004	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4527	17041-20001-35688	415 S HARVARD BLVD 1-45	90020	10	135B193   477	5503011024	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.06664	-118.3043	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 29.92 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4528	16041-20001-09984	20318 W STRATHERN ST	91306	3	189B113   510	2107025058	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.21546	-118.57613	Expedited per applicant request. Plan check for the addition of a 9.2 kWac PV system onto an existing 3 kWac PV system for a total system size of 12.2 kWac. System addition consists of (2) inverters, (44) modules, (1) combiner box, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4529	10041-20000-03994	725 S FIGUEROA ST 5th&6th fl	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	04/15/2010 12:00:00 AM		Permit Finaled	07/29/2010 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check power and energy for TI on 5th and 6th floor of existing high rise building.  Modification to seperate fire alarm system from plans has been filed.  Transformers/panel 7RP5 will be installed on 7th floor, panel 3PA on 3rd floor, and panels 8RP5/8RPS/UPS8A on 8th floor. No ckts in new panel will installed on 7th and 8th Floor. All loads for new panel on 7th and 8th floor under seperate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4530	12041-20000-22296	6420 W WILSHIRE BLVD Suite 100	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for energy and emergency lighting. High rise commercial. 8642 sqft. Suite 100. Nikon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4531	14041-20000-08413	7315 N FIGUEROA ST SUITE 107	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.13628	-118.18852	Tenant improvement of beauty salon - Nail Couture.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4532	17041-10000-02141	695 S VERMONT AVE #110	90005	10	132B197   178	5094008026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	10/22/2017 12:00:00 AM	ADDRESS	34.06016	-118.29183	Plan check for Titel 24 only in existing restaurant #110 T.I. . Total area: 4195 sq ft. Load less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4533	18041-10000-20929	20747 W DEARBORN ST	91311	12	198B109   144	2748036022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Issued	07/30/2018 12:00:00 AM	ADDRESS	34.23734	-118.58591	*Permit fee is zero dollar per SB-1222/ AB-1414*PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 63.51 kW DC/ 61.63 kW AC, (174) modules, (2) central inverters, (1) 125A subpanel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4534	17041-10000-15713	4210 S CRENSHAW BLVD	90008	10	114B185   590	5024017011	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.00797	-118.33485	T24 ONLY. REPLACE EXISTING HID LIGHT FIXTLURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA  4800 SQ FT. OUTDOOR  LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4535	19041-20000-50469	14460 W BEAVER ST	91342	7	219B149   762	2507012013	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.2946	-118.44836	PV1.  Install 6.120 kW DC / 5.282 kW AC-CEC roof mounted grid tied PV system.  (24) modules with 5 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4536	17041-20000-41209	10900 W WILSHIRE BLVD Ste 170	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	Conversion of office space into restaurant in commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4537	17041-20003-24776	8500 N BALBOA BLVD SUITE #170	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Closed	10/07/2020 12:00:00 AM	ADDRESS	34.22485	-118.50045	"3/6/2018changes to an approved set of plans.  changes to include additional panel ""LLP9"" and accessory loads.  plan check for power only.  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area of 96,648 sq. ft.Note: Building application has been generated under 17016-10000-15426)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4538	14041-20001-16592	20307 W VIA SANSOVINO	91326	12	219B113   269	2701061009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.29685	-118.57578	Expedited plan check fee per applicant request.  (((PV1.  Install 6.86 kW roof-mounted, utility-interactive PV system.  Transformerless inverter: SunnyBoy 6000TL-US-22)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4539	16041-20000-27837	1443 N DEVLIN DR	90069	4	147B169   938	5560001028	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Refund in Progress	09/08/2016 12:00:00 AM	ADDRESS	34.09572	-118.38735	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4540	14041-20000-12935	22110 W ROSCOE BLVD Lobby	91304	3	192B101   669	2012002019	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM			Corrections Issued	05/14/2014 12:00:00 AM	ADDRESS	34.21937	-118.60854	Add to medical office - lobby.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4541	15041-10000-16676	6100 W WILSHIRE BLVD STE 1530	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.06282	-118.36187	TI TO AN EXISTING COMMECIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 603. SCOPE OF WORK TO BE PERFORMED IN SUITE 1530 IN THE 15TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4542	13041-20000-31251	7737 N NITA AVE	91304	3	189B101   728	2012019015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.21117	-118.61384	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.924KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4543	10041-20000-22337	20022 W VENTURA BLVD	91364	3	174B113   466	2166001020	C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.17141	-118.56915	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR RESTUARANT TI. PERMIT FOR NEW (2) PANELS AND NEW CKTS. MISC PERMIT TO RE-FEED EXISTING BRANCH CKTS TO NEW PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4544	14041-20001-24803	7000 S HOOVER ST Unit #7	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	expedite feesNew roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #7.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4545	13041-10000-25580	8955 W PICO BLVD	90035	5	132B169   766	4332008002	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.05544	-118.38726	Remove HID light fixtuers and install new flourescent fixtures.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4546	12041-10000-20563	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	33.97451	-118.42531	PLAN CHECK FOR SITE LIGHTING-NEW PANELBOARDS AND CIRCUITS FOR HARDSCAPE LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4547	16041-10002-36832	13373 W DEL SUR ST	91340	7	213B157   291	2524019018	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Issued	01/31/2017 12:00:00 AM	ADDRESS	34.28146	-118.42486	CHANGE TO SYSTEM. INVERTER IS NOT NOTED AS 3.1KW AC. NO OTHER CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4548	19041-20001-22491	10350 W WYTON DR	90024	5	138B157    54	4359013002	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM			PC Approved	10/04/2019 12:00:00 AM	ADDRESS	34.07521	-118.43091	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO SINGLE LINE FEEDER MATERIAL TO ALUMINUM, CHANGE PANEL SIZE FROM 125A TO 225A.  APPROVAL FOR CLOUDED REVISIONS ON E-2.0 THRU E-2.1 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4549	17041-20000-36684	9570 W PICO BLVD 4TH FLOOR	90035	5	132A167   257	4306002022	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.05499	-118.39734	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 5849 SQFT. 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4550	17041-20000-17717	18518 W PARTHENIA ST	91324	12	195B125   900	2785004031	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			PC Info Complete	07/28/2017 12:00:00 AM	ADDRESS	34.22805	-118.53686	T.I. to (E) commercial building for agricultural usage.  Plan check for power and energy (load exceeds 400A).  Building permit application filed under 17016-20000-14054(Title 24 square footage to be added to fees prior to plan submittal)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4551	15041-10000-39592	1601 N VINE ST	90028	13	148-5A187 301	5546009906	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	New fire alarm for a HIGH RISE BUILDING with 8--story core and shell office/retail building with 5 levels of subterranean parking. Scope include (2) fire alarm panels, (13) control panels, (1) communication panel, and 445 fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4552	14041-10000-08198	8520 S BROADWAY	90003	9	097-5A203 256	6040009027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	33.96097	-118.27809	pc for power only. not oshpd-3 per applicant. medical office: planned parenthood. structural calcs included.BLDG#14016-10-05784: INSTALLATION OF A NEW 10 KVA RACK INSDE STORAGE ROOM OF (E) COMMERCIAL BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4553	11041-10001-24028	13843 W MILBANK ST	91423	2	168B153   842	2271005003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2011 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.15313	-118.43448	PLAN CHECK ROOF MOUNTED ENPHASE M215 PHOTOVOLTAIC SYSTEM. SINGLE FAMILY DWELLING. EXISTING CENTRAL INVERTER PV SYSTEM INSTALLED. PREVIOUS APPLICATION WAS EXPRESS PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4554	19041-20000-32318	444 S FLOWER ST 35TH FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM			Corrections Issued	08/19/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	TENANT IMPROVEMENT FOR COMMERCIAL OFFICE IN HIGH-RISE BUILDING. TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4555	11041-10000-04937	9301 N TAMPA AVE # 117	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM			Corrections Issued	03/14/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVEMENT IN A RETAIL STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4556	16041-10003-38001	4061-4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.99055	-118.44379	**applicant requested to have the same plan check engineer as the master plan: Isaac Almaraz**DELTA 2 CHANGES - CHANGE OF ENGINEER.2nd changes to approved plan. All changes are clouded on the plan (Requested applicant to indicate Delta-2 on every changes on this plan). Scope includes adding 50000 SQ.FT OF CREATIVE OFFICE SPACE WITH  UPGRADED panels, NEW  circuitry and equipment. ((((PC FOR POWER AND ENERGY FOR A MIXED USED BUILDING (49 UNITS)SCOPE INCLUDES NEW SERVICE (4000A /480V)B#16010-10000-04167)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4557	11041-10001-09377	1800 N WHITLEY AVE	90028	13	150A187   372	5547005008	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.10353	-118.33319	Revisions to permitted set of plans.feeders are changed to Aluminum .apartment panel boards circuit breakers are 100 (Max load on panels is 90A); EMERGENCY LIGHTING SOURCE IS THE GENERATOR-unit equipment were removed and two panels install forthe circuits;(((((((((NEW 32 UNIT APARTMENT BUILDING WITH, GYM, AND 2 LEVELS OF PARKING ( ONE BELOW GRADE AND ONE ABOVE).  FIRE ALARM TO BE SUBMITTED SEPARATELY.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4558	18041-30000-29184	2029 S CENTURY PARK EAST #860	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Energy plan check for an office T.I located in the 8th floor of a high rise building. Scope includes new lighting and equipment with a total area of  9,488 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4559	12041-10000-24214	4170 S PADILLA PL	90008	8	114B177    37	5029017***	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.00964	-118.3624	NEW COMMUNICATIONS BUILDING FOR THE CITY OF LOS ANGELES-INFORMATION TECHNOLOGY AGENCY.  26' X 47'; At time of approval of plans, the engineer inform us that the DC portion of the singleline diagram will be delayed and not to be included in the approved plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4560	11041-20000-26511	2022 S LOUELLA AVE	90291	11	111B149   593	4242016018	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM			Reviewed by Supervisor	01/04/2012 12:00:00 AM	ADDRESS	34.00085	-118.45154	New 7.2 KW roof mounted PV system with a battery back up system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4561	16041-10001-42022	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	PIN	33.92817449	-118.43220714	03/01/16Changes to an approved set of plans. All changes are clouded under delta 2. Changes include changing out adjustable circuit breaker ratings from 640AT to 600AT on the single line diagram.Note: Permit is paid under PCIS#16041-10000-42022	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4562	19041-20001-22423	8862 W PICO BLVD	90035	5	132B169  1141	4305014***	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM			PC Approved	08/05/2019 12:00:00 AM	ADDRESS	34.05475	-118.38522	Expedite per applicant request Plan check for PV roof mounted system, System size: 21.045KW with 61 PV  Modules and 2 inverters(9KW) connected to 2000A distribution system.Note: Building permit for Solar roof top is required(solar panel is above 4 feet from roof) prior to approved plans	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4563	14041-20001-03660	14554 W VALERIO ST	91405	6	186B149   572	2218016004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.20472	-118.4508	Roof mounted PV system with 4.5KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4564	19041-20000-36918	15268 W RAYNETA DR	91403	4	165A147   348	2277013008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Issued	09/16/2019 12:00:00 AM	ADDRESS	34.14499	-118.4654	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 8.19 KW DC/7.6KW AC. ALSO A NEW 40.5 KWH BATTERY ENERGY STORAGE SYSTEM. SCOPE OF WORK CONSISTS OF (26) PV MODULES WITH OPTIMIZERS AND A 7.6KW INVERTER , (3) 13.5 KWH BATTERIES, AND (3) SUB PANELS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4565	18041-10000-16263	6301 W 3RD ST	90036	4	138B177  1148	5512003043	[T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.07243	-118.35963	PLAN CEHCK FOR TITLE 24 ONLY FOR - tenant improvement for Coffee Bean And Tea Leaf - TOTAL AFFECTED AREA = 909 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4566	17041-20000-36360	18622 W HILLSBORO ROAD	91326	12	207B121   759	2728031043	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.26088	-118.54092	Install 54 kWh energy storage system.  (E) solar PV system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4567	13041-10000-35389	1015 S CROCKER ST STE Q19	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH FLUORESCENT FIXTURES. 2155 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4568	16041-10002-02087	1025 S STANFORD AVE	90021	14	124-5A211 328	5132009019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.03336	-118.24926	INSTALLATION OF FIREPUMP. JOCKEY PUMP, AND DISCONNECT AHEAD OF FIREPUMP. SERVICE TAP  IN SAME SECTION OF SERVICE DISCONNECT ( ELECTRICAL INSPECTOR WANTS OUTSIDE CERTIFICATION FOR THE TAP). SERVICE CONDUCTOR/DISCONNECT  ARE  IN THE ELECTRICAL ROOM. WIRING FROM DISCONNECT OUTSIDE TO FP  IS INACCORDANCE WITH  ARTICLE 695 (((((FULL PC, CHANGE OF USE FROM EXISTING WAREHOUSE TO WHOLESALE MALL;	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4569	17041-10000-24195	6540 N FIRMAMENT AVE	91406	6	180B145   435	2234006015	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM			PC Info Complete	07/18/2017 12:00:00 AM	ADDRESS	34.18991	-118.47149	SOLAR SYSTEM FOR PATIO COVER ADDITION. THIS IS THE PV PERMIT FOR MODULES AND INVERTER WIRING. ZONING CLEARED FROM BUILDING PLAN CHECK	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4570	16041-10000-14568	1616 W 209TH ST # 1	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	PV1 INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A MULTI- FAMILY HOUSE.(6) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4571	11041-30000-25672	2930 E 12TH ST	90023	14	118-5A221  35	5169008***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM	12/01/2011 12:00:00 AM		Permit Finaled	02/22/2012 12:00:00 AM	ADDRESS	34.02001	-118.21593	energy plan check permit to pay for 8 circuits and reconnecting a/c by inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4572	16041-20000-30264	13908 W SUNSET BLVD	90272	11	129B133   347	4408011006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.04635	-118.50817	Plan check for a PV1 roof-mounted PV system. System size is 7.7 kWac and consists of (1) inverter and (22) modules. System interconnectes to a 400-amp rated MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4573	15041-20000-07781	10010 N REMMET AVE	91311	12	204B105   820	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.25239	-118.60035	Plan check for power only.  Installation of 1 new 1,000 gal. horizontal propane tank.  Project is considered a class I division II hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4574	18041-20000-08355	16255 W VENTURA BLVD 3rd Floor-Corr.	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.15711	-118.48768	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 601 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4575	16041-20000-05824	18120 W KINZIE ST	91325	12	201B125   237	2764019003	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	34.24802	-118.52837	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (23) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4576	14041-10000-14472	6268 W PRIMROSE AVE	90068	4	151-5A189 226	5586001036	R1-1	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.10966	-118.32559	PV1, INSTALL 7.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER, WITH OTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4577	11041-10000-22134	8100 W MELROSE AVE	90048	5	141B177   625	5528010037	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM			PC Approved	11/03/2011 12:00:00 AM	PIN	34.08348986	-118.36608569	T.I. to an existing retail building.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4578	15041-10000-09966	11316 W GOSS ST	91352	6	192B173   413	2632004030	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.22273	-118.37746	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4579	16041-20002-45056	6611-6639 N RESEDA BLVD	91335	3	180B125   833	2126038026	(T)(Q)RAS4-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM			PC Approved	01/04/2019 12:00:00 AM	ADDRESS	34.19075	-118.53639	01/04/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the lighting floor plans. Changes have been reflected onto load calculations and Title 24 compliance forms. *****Previous Work Description*****Revisions to approved set.  Various changes under delta-1: - switchgear manufacturer changed- main feeder to apartment meter sections modified- - single main service disconnects eliminated in favor of not more than 6 grouped main service disconnects- addition of 2 new subpanels for garage fans- pool panel changed to 3-phase- fire pump meter/disconnect relocated*****Original Work Description*****Plan check for power and energy. Mixed Use - 5-Story 250-unit  Apartment over 1 story  parking / Retail. (2) 208Y/120V 3ph-4w services at 4000 and 5000A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4580	10041-10000-14324	19649-19661 W VENTURA BLVD	91356	3	174B117   306	2164013026	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.17284	-118.56162	Install new exterior lighting to existing buidling.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4581	14041-20000-15222	20406 W LORNE ST	91306	3	189B113   226	2107003010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.21727	-118.57768	PV1.  Install 3.06 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4582	18041-10001-00508	10356 N GERALD AVE	91344	12	204B137   118	2684017010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			Reviewed by Supervisor	01/17/2018 12:00:00 AM	ADDRESS	34.25917	-118.49456	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4583	18041-10000-20031	755 S LOS ANGELES ST	90014	14	127-5A211 253	5145001013	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	34.04231	-118.25201	CORE/SHELL FOR (E) 5-STORY MIXED-USE WITH 3000-AMP SERVICE : BASEMENT TO 1ST FL AND MEZZ WILL BE RETAIL/RESTAURANT; 2ND FLOOR TO 5TH FLOOR WILL BE OFFICES; ROOF WILL HAVE A RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4584	11041-10000-08386	3115 S SEPULVEDA BLVD	90034	5	120B157   416	4251013001	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.02601	-118.42781	TENANT IMPROVEMENT FOR BIG LOTS RETAIL STORE. NEW 800 AMP SERVICE, NEW AC UNITS & NEW LIGHTING. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4585	13041-10000-33271	119 E CULVER BLVD	90293	11	096B149   514	4116007031	[Q]C4-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	33.95798	-118.44957	FULL PLAN CHECK FOR POWER AND ENERGY TO AN PROPOSED INTERIOR/EXTERIOR RESTAURANT REMODEL TO (E) RESTAURANT, SINGLE STORY. PLACE OF ASSEMBLY (A-2) WITH MAX OCCUPANT LOAD OF 266 PER BUILDING PERMIT 13016-10000-16478. TOTAL PROJECTED AREA OF ILLUMINATION IS 6084 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4586	18041-10000-29423	1063 E 42ND ST	90011	9	114A209    90	5115022001	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2283.20	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.00767	-118.25697	PV2, NEW PV SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS IN A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW (72) MODULES AND OPTIMIZERS AND (2)10KW INVERTERS. TOTAL SYSTEM SIZE IS 20KWAC AND 23.4 KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4587	15041-10001-35078	118 S ASTRONAUT ELLISON S ONIZUKA ST	90012	14	130-5A213 136	5161016025	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	34.05046	-118.24184	Change to approved set by upsizing the fire pump and generator. load calculation being updated. lighting fixture being changed, and T-24 also being updated. All changes under delta-4 only.See comment for detail.(((PC FOR POWER AND ENERGY. NEW 9 STORY 77 UNIT MIXED USE APARTMENT BUILDING OVER 3 LEVEL SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES A NEW 4000A 120/208V 3 PHASE 4 WIRE SERVICE, NEW PANELS, NEW CIRCUITS,  AND NEW LIGHTS. TOTAL AFFECTED AERA IS 125424 SQ. FT. B#15010-10000-02939)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4588	14041-10001-22130	3033 W WILSHIRE BLVD	90010	10	135B197  1240	5077008018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.06198	-118.28733	06/30/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include removing two horn strobes, adding 3 methane gas detectors, and revising battery calculations. ((((((New methane gas detection system for new 17 story apartment building.  Total # of devices = 52**SEE APPLICATION COMMENTS**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4589	16041-20000-09497	7440 N SEPULVEDA BLVD	91405	6	186B145   417	2221005001	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			03/22/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.206	-118.46584	$0 permit fee is due to State Senate Bill SB 1222. Plan check for a PV2 roof-mounted PV system. System size is 66.6 kWac and consists of (2) inverters, (228) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4590	17041-20000-35560	9315 W WAYSIDE DR	91040	7	207B185   462	2547021044	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.26142	-118.33412	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.6KW.  STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4591	14041-20000-17321	6301 N OWENSMOUTH AVE 3rd floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.18467	-118.60176	Commercial office TI on 3rd floor of (E) commercial highrise building.  Power and energy plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4592	15041-10000-35987	150 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM			PC Info Complete	11/13/2015 12:00:00 AM	ADDRESS	34.07452	-118.32343	Energy plan check for a restaurant T.I (in/outdoor lighting) Scope includes new lighting and equipment; Total area is 755-SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4593	19041-20000-52662	1529 E NEWTON ST	90021	14	121-5A213 319	5130020012	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			Reviewed by Supervisor	01/29/2020 12:00:00 AM	ADDRESS	34.02557	-118.24238	FULL PLAN CHECK, FIRE REPAIR, NEW 800A SERVICE, (4) PANELS WITH LOADS, (2) 75 KVA TRANSFORMERS. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 8925 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4594	16041-20000-24820	9152 N LEMONA AVE #118	91343	7	198B145   295	2651001***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Issued	07/14/2016 12:00:00 AM	ADDRESS	34.23707	-118.45871	Plan check for PV roof mounted system. System size: 8.2kW with 36 modules and 1 inverter(8.6kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4595	16041-20000-40404	3332 E GRANADA ST	90065	1	147A219   214	5454027034	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Info Complete	11/22/2016 12:00:00 AM	ADDRESS	34.09704	-118.22661	PV1.  Inspire 2.616 kW DC roof-mounted grid-tied PV system.  (8) modules with (1) 3.0 kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4596	15041-20001-12502	23472 W FRIAR ST	91367	3	177B093    18	2035009001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2015 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	34.18548	-118.63932	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 5.375 kWac.  Microinverter system with 2 branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4597	12041-10000-15068	1505 S PERRINO PL	90023	14	118-5A219  10	5169015014	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			Reviewed by Supervisor	08/22/2012 12:00:00 AM	ADDRESS	34.02018	-118.22248	Plan check for 134.5KW roof mounted photovoltaic system for existing commercial building with two services. Second service photovoltaic system under #12041-10000-15074. (Application 1 of 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4598	16041-10000-06491	2700 W COLORADO BLVD # 145	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.14248	-118.22438	PC FOR ENERGY. T.I FOR A FAST FOOD RESTURANT IN A SEA FOOD MARKET. ( EAGLE ROCK PL) TOTAL AREA IS 1417 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4599	18041-10001-39836	7459 N SHIRLEY AVE	91335	3	186B117   438	2116006072	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.20629	-118.55803	NEW 11.5KW ROOF MOUNTED PV SYSTEM WITH 32 AC MODULES ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4600	14041-10000-33158	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.09676	-118.29487	T24 ONLY laundry and support areas. TOTAL AREA 655 SQ FT. loads are to be added to an existing panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4601	17041-20000-27914	12174 N CANYON HILL AVE	91342	7	216B145   241	2611043012	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.29189	-118.46602	pv1install roof mounted pv system sized 4kw intefconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4602	16041-20001-08868	870 S HILGARD AVE 1-77	90024	5	135B153   384	4360007028	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.06469	-118.4407	RSES expedited plan check per applicant request.  PV2.  Install 81.9 kW roof-mounted PV system.  (5) 14kW inverters with (260) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4603	12041-20000-18969	6767 W FOREST LAWN DR	90068	4	162B181   617	5581028005	C1-1D	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.14432	-118.33993	T.I. to existing building in suite 318.  Install general/emergency lighting.   Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4604	16041-10000-28141	1268 E 27TH ST	90011	9	117A211   118	5119019019	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.01569	-118.25107	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(11)MODULES-KYOCERA#KU2656ZPA(1)INVERTER-PV-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4605	14041-10000-30150	380 WORLD WAY Space T82	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for a T.I  of airport concession space #T82 (USA Today)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4606	17041-30000-45064	2029 S CENTURY PARK EAST 6th & 7th-Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,745 sq. ft.Note: Building permit has been issued under 17016-10000-13368	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4607	16041-10000-33227	260 S HIGHLAND AVE	90036	4	135B185    81	5513028011	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.06922	-118.33836	PC FOR PV.  SYSTEM SIZE IS 8.35KACUSING STANDARD PLAN TOTAL OF 28 MODULES (CANADIAN SOLAR CS6P- 270P)SOLAR EDGE OPTIMIZERS MODEL P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4608	14041-20000-05945	13630 W WILLARD ST	91402	6	189B157   159	2213019041	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.2175	-118.42943	Install outdoor signages.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4609	14041-20000-07640	3663 S ST ANDREWS PL	90018	8	120B193  1550	5042017003	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.02139	-118.31204	PV1 MICROINVERTER NONSTANDARD PLAN. TOTAL SYSTEM SIZE 1.4KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4610	19041-10000-31694	230 N BARRINGTON AVE	90049	11	135B145   325	4429024006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM			Verifications in Progress	09/25/2019 12:00:00 AM	ADDRESS	34.06747	-118.47139	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 12.8KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SOLIVIA 5.2TL & SOLIVIA 7.6 TL) WITH 39 MODULES(HANWHA Q-CELLS BLK-G5/SC315) WITH 3 ESS(TESLA POWERWALL) CONNECTED TO AN EXISTING 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4611	16041-20001-18232	8500 N BALBOA BLVD	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.22485	-118.50045	[[12/1/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA (4) CHANGES ARE CLOUDED. CHANGING FEEDER P6 AND P6-A]]]]PC FOR ENERGY AND POWER. SITE UPGRADES TO EXISTING OFFICE/INDUSTRIAL CAMPUS.  INCLUDES: NEW SIDEWALK FOR ACCESSIBLITY COMPLIANCE; IMPROVEMENTS FOR VEHICULAR/PEDISTRIAN EFFICIENCY; PARKING RESTRIPING; SITE LIGHTING; LANDSCAPE AMENITY AREAS; AND RELOCATION OF SITE DRIVEWAY ENTRIES. TOTAL AREA 619117 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4612	13041-10001-17515	20050 S VERMONT AVE	90502	15	057B197   154	7351033062	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	33.84838	-118.29024	MODIFICATION TO APPROVED SET: WALL-MOUNTED SPEAKER STROBES CHANGED TO CEILING MOUNTED, CONNECTED TO EXISTING DUCT DETECTOR LINES.  (((PLAN CHECK FOR FIRE ALARM IN A CHURCH.  96 DEVICES AND 1 PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4613	10041-10000-22527	1127 W WILSHIRE BLVD	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Public Safety Only			11/09/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	03/28/2012 12:00:00 AM	ADDRESS	34.05287	-118.26415	new fire warning system for a medical building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4614	19041-20000-28479	10415 W CUMPSTON ST	91601	2	174B177   823	2417010012	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.17042	-118.35761	Plan check for PV roof mounted system, Energy Storage System, PV system size: 4.095KW with 13 PV Modules and 1 Battery Tesla Power 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4615	15041-20000-06681	8813 N AMBOY AVE	91352	6	195B165   574	2634034022	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.22896	-118.3978	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  16 modules with miroinverters on 1 branch circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4616	11041-20000-25543	15760 W VENTURA BLVD Ste 1450	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	ADDRESS	34.1552	-118.47684	Mofication to an existing fire alarm system.  The modifications include the addition of 6 new devices and the relocation of 1 existing devices in Suite 1450	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4617	11041-20000-06106	12210 W SANTA MONICA BLVD	90025	11	126B145   798	4263037022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.03986	-118.46447	T.I. to existing building (Smart and Final).  Relocate lighting fixtures.  Plan check for energy only.Note:  Permit issued under 11041-20000-06107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4618	19041-20002-23264	20865 W LASSEN ST	91311	12	201B109    90	2741002005	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM			PC Approved	12/13/2019 12:00:00 AM	ADDRESS	34.25013	-118.58809	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGE ONLY, CHANGE TO T24 SHEET, CHANGE TO REQUIRED DOCUMENT INDICATORS AND MANDATORY DEMAND RESPONSE CONTROL AND INDICATION OF NO SKYLIGHT/DAYLIGHT SENSORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4619	12041-10000-03176	11505 N SWINTON AVE	91344	12	213B137   585	2605022021	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	03/28/2012 12:00:00 AM	ADDRESS	34.27943	-118.48611	Plan check roof mounted 1.38KW Enphase M215 Microinverter photovoltaic system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4620	16041-20003-37189	13261 W PAXTON ST	91331	7	213B157   688	2523020025	(Q)M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	34.27702	-118.42191	[[[ 3/9/17 CHANGES TO APPROVED SET. UPDATING PLANS TO PROVIDE PANEL SCHEDULES ON PLANS. ADDING TWO NEW AC UNITS. UPDATING FAULT CURRENT]]]]800 amp service upgrade.  reconnect feeders.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4621	18041-20000-04355	2337 N HIGH OAK DR	90068	4	153B193   292	5587003021	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.11299	-118.31207	addition of (2) tesla powerwalls to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4622	19041-10000-27425	2160 W ADAMS BLVD	90018	10	123B189   697	5052031021	R3-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.01	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.03248	-118.3142	T-24 PLAN CHECK FOR OUTDOOR LIGHTING. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1865 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4623	18041-10000-29633	21418 W DEVONSHIRE ST	91311	12	204B105   315	2747010048	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.25704	-118.59817	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4624	16041-30000-02196	6080 W CENTER DR suite 850	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	33.97713	-118.39172	Title 24 plan check only.  Total area = 5,545 sq. ft.   T.I. to existing commercial office highrise space.  New 225 A panel + lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4625	18041-20000-19179	4423 N SHERMAN OAKS CIR	91403	5	166-5A145  88	2283019003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.15116	-118.47048	PV1.  Install 15.75 kW roof mounted grid tied PV system.  (50) modules with 11.4 and 3 kW rated string inverters.$17.93 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4626	15041-10000-24599	1800 S AVENUE OF THE STARS 6th Flr	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	Energy plan check for an office T.I located in the 6th floor of a high rise building. Scope includes new lighting, equipment and receptacles. Total area is 7855-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4627	16041-20001-27079	17780 W RIDGEWAY ROAD	91344	12	213B129    92	2601039028	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.28287	-118.52091	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (44) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4628	19041-20000-44809	3761 W TRACY ST	90027	4	150B201  1010	5433021019	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.10546	-118.27482	PV1 PLAN CHECK FOR 8KW DC/6.98 KW AC PV SYSTEM. SCOPE OF WORK CONSISTS OF (20) PV MODULES WITH MICROINVERTERS, AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4629	18041-10000-39943	1654 S GREENFIELD AVE 1-8	90025	5	129B153   553	4324030010	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.04935	-118.4417	NOTE: FEES ARE ZERO PER ASSEMBLY BILL 1414PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 28.8KVA SYSTEM CONSISTING OF 2 INVERTERS (SE 14.4K-US) WITH 88 MODULES USING P320 POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4630	15041-10000-09040	523 W 7TH ST	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.04717	-118.25611	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 1430.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4631	15041-10000-13711	870 E 59TH ST	90001	9	105B209    38	6007004003	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	03/03/2023 12:00:00 AM	ADDRESS	33.98709	-118.25953	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FIXTURES. TOTAL AREA 20664 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4632	18041-10000-27160	9217 S AIRPORT BLVD	90045	11	093B169    89	4124009920	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	33.95197	-118.38615	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4633	19041-20000-14392	6461 N PENFIELD AVE	91367	3	180B113   685	2134038013	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.18827	-118.56925	Plan check for battery back up system in to existing PV system, install 3 Power Wall 2.0 (13.5KWh)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4634	14041-10000-06442	1302 W 177TH ST BLDG E	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	INSTALLATION OF A FIREALARM FOR A NEW MULTIPURPOSE COMMUNITY ROOM BUILDING (BUILDING E).  1 PANEL AND 22 DEVICES.5 OF 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4635	18041-10000-36448	13460 W VENTURA BLVD	91423	4	165B157  1186	2373007008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Closed	05/09/2024 12:00:00 AM	ADDRESS	34.147	-118.427	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4636	13041-10000-14358	3709 S TROUSDALE PKWY	90089										Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.01851	-118.28672	PLAN CHK TO VERIFY THAT LUMINAIRES IN ROOMS 102;105;106 ARE IN COMPLIANCE AFTER LUMINIRES WERE CLEANED AND RETURNED TO ORIGINAL INSTALLATION;MANDATORY MEASURES ARE ON THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4637	12041-10000-27070	18222 W COLCHESTER WAY	91326	12	213B125   471	2870013055	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.2786	-118.532	PLAN CHECK (ONLY)  REQUESTED BY INSPECTOR. PV1 SOLAR INSTALLATION.  ROOF MOUNTED, 40 MODULES AND 10.20KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4638	16041-20001-16888	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.30363	-118.45814	[[[3/22/17 CHANGES TO APPROVED SET, T24 PLANCHECK  DELTA 1 CHANGES ONLY. REDESIGN BATHROOM AND LIGHTING ADJUSTED TO MEET NEW DESIGN.]]]Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement/addition of a mezzanine. Total lighting area = 3,930 sq. ft.Note: Building application has been created under 16014-20000-02211	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4639	17041-20000-04236	14221 W COVELLO ST	91405	2	186B153   894	2215001020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.20724	-118.44307	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. 2400 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4640	11041-10000-02409	12730 S FIGUEROA ST	90061	15	081B201   254	6132019042	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	06/27/2011 12:00:00 AM	ADDRESS	33.91687	-118.28256	New methane detection system. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4641	18041-20000-41576	18133 W HATTERAS ST	91356	3	174B125    70	2157011013	R1-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.17647	-118.52846	Plan check for a PV1 roof-mounted PV system. System size is 10.56 kWdc/9.71 kWac-CEC and consists of (32) modules, (32) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4642	16041-10001-22482	631 S OLIVE ST SUITE 302	90014	14	129A209   124	5144004032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.04749	-118.25498	7/11/16: Revision to approved set of plan. Revised Type of lighting and manufacture. All changes noted under Delta-1. This is PC only, Permit under the master PCIS#.<<T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT ON THE 3RD FLOOR OFFICE SUITE 302 IN EXISTING STORY OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 2065 SQ. FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4643	13041-20000-30796	3700 N COLDWATER CANYON AVE	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.13809	-118.41286	PC FOR T24 ENERGY ONLY. LOAD LESS THAN 400A. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4644	17041-20000-10997	14911 W CALVERT ST	91411	6	178-5A149 317	2242024048	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	PIN	34.18170177	-118.45786314	service upgrade to an existing commercial building 1600 amps with new panels.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4645	12041-10000-07830	13108 W ALBERS ST	91401	5	174B161   659	2345005039	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.1702	-118.41843	New 7.09kw rooftop photovoltaic system for an existing single-family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4646	11041-10000-05525	725 S FIGUEROA ST 4th floor	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.04886	-118.26071	Ti in bathrooms on the 4th floor. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4647	18041-20000-02605	16830 W VENTURA BLVD Suite 150	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Closed	03/30/2018 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 4,952 sq. ft.Note: Building permit has been issued under 17016-20000-23091	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4648	16041-10000-02072	9449 N BIANCA AVE	91325	12	198B129    34	2766019003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.24276	-118.5143	PV1, Install 2.12 kW DC roof-mounted solar array, interconnected to existing pv systems through a load center. (1) INVERTER:  ABB PVI-3.0-OUTD-S-US-Z-A.  (8) Modules: KYOCERA  KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4649	10041-10000-00951	10800 W PICO BLVD # 257	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	02/02/2010 12:00:00 AM		Permit Finaled	03/24/2010 12:00:00 AM	ADDRESS	34.04054	-118.4272	INTERIOR TENENT IMPROVEMENT REMODEL OF EXISTING RETAIL STORE (Crazy 8 )plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4650	12041-20000-12803	4900 N VINELAND AVE 1-82	91601	2	168B173   211	2421011002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			06/04/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.1595	-118.37008	New fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4651	14041-20001-17832	301 N MCFARLAND AVE	90744	15	027B209    18	7424016911	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Special Equipment			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	33.77348	-118.25297	[[1/27/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. DELTA 1 CHANGES]]]]]Plan check for power only.  Remove and replace ATS, generator, VFDs, pumps, and motors in existing industrial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4652	14041-10001-30406	723 S DODSON AVE	90732	15	015B193   504	7560002025	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	33.73727	-118.31204	((((Expedited per applicant's request))))Installation of 7.54 kW DC roof-mounted PV1 system. System consists of (29) 260 W panels and (1) 7600 W rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4653	15041-20000-33227	3332 E GRANADA ST	90065	1	147A219   214	5454027034	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.09704	-118.22661	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4654	15041-10000-22295	287 S 26TH ST	90049	11	129B137   580	4264001012	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	PIN	34.04684609	-118.48975839	TENANT IMPROVEMENT TO EXISTING BANK WITH NEW FINISHES, NON-BEARING PARTITIONS, PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4655	19041-10000-10035	1875 S CENTURY PARK EAST 1900	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.06115	-118.41457	ENERGY PLAN CHECK FOR AN INTERIOR OFFICE TI LOCATED ON THE 19TH FLOOR OF A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND AND EQUIPMENT WITH A TOTAL AREA  OF 7,024-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4656	17041-10000-30466	13571 W DESMOND ST	91331	7	210B157    67	2523004036	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.275	-118.42842	TITLE 24 PLAN CHECK TO REMOVE EXISTING (5) HID FIXTURES AND REPLACE WITH LED FIXTURES. 13125 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4657	13041-20000-32424	2300 S HILL ST	90007	9	121-5A205  71	5126034020	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.0283	-118.26892	T24 FOR EXISTING OFFICE BUILDING. TOTAL SQRFT 4215	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4658	19041-20000-47854	5021 E SHIPLEY GLEN CT	90042	1	151-5A225  82	5469009009	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	PIN	34.11086918	-118.20531883	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 3.78 KW DC. SCOPE OF WORK CONSISTS OF (12) PV MODULES AND A 3.8 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4659	19041-10001-45381	13727 W CHANDLER BLVD	91401	4	171B157    61	2247014049	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.16872	-118.43212	NEW ROOF MOUNTED 13.2 KW PV SYSTEM WITH 40 PV MODULES AND ENPHASE MICRO INVERTERS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4660	19041-20002-00046	5670 W WILSHIRE BLVD 100	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	11/14/19CHANGES TO APPROVED SET DELTA 8 ONLY.<<<Plan check for Title 24 only in existing space Interrior Remodel Total area: 7789 sq ft. B-18016-10000-41259>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4661	15041-10000-10507	3785 W WILSHIRE BLVD STE 107F	90010	4	135B193  1032	5503001***	R4-1	Central	Wilshire	Greater Wilshire		2117.03	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.06187	-118.30858	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1095.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4662	13041-10000-22353	5009 W EXPOSITION BLVD	90016	10	120B181   842	5046012008	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.0248	-118.35248	TI for existing 2-story office building.  T24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4663	15041-20000-23328	13245 W SHERMAN WAY	91605	2	183B157    50	2327002036	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.20135	-118.42186	plancheck for t24 energy. T.I. to the existing office, remodel exterior fascade. 2030 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4664	19041-20000-40206	668 S ALAMEDA ST	90021	14	124-5A215  51	5164023023	[T][Q]C2-2D-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			10/31/2019 12:00:00 AM	04/12/2021 12:00:00 AM		Issued	04/12/2021 12:00:00 AM	ADDRESS	34.0358	-118.23837	1200A 4.16 kV 3ph-3w service, distribution, power, and lighting for new mixed-use development.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4665	15041-20000-17661	11965 W MONTANA AVE 1-49	90049	11	129B141   303	4265007078	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.05133	-118.47199	Plan check for power and energy. Project site is a new 49-unit apartment building. Build has 6 floors of tenant spaces and 2 levels of underground parking. Work includes (1) 2500-amp service, (14) meter sections, (51) unit and house panels, and associates loads. Total common indoor lighting area = 46,717 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4666	18041-10000-46798	7804 N LANKERSHIM BLVD	91605	6	189B169   732	2311015030	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.21227	-118.38758	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4667	15041-20000-22251	5000 W SUNSET BLVD Suite 600	90027	13	147B197   756	5543024022	C2-1D	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.09788	-118.29844	Title 24 plan check only.  Total area = 1,796 sq. ft.  T.I. to existing low rise commercial office space.  Alternate lighting scheme under application #15041-20000-22252.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4668	17041-10000-41774	6305 N WOODMAN AVE	91401	2	177B157    81	2239006029	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	01/27/2024 12:00:00 AM	ADDRESS	34.18528	-118.43145	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4669	15041-10000-11049	19817 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.85065	-118.28823	T24 ONLY, REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 2436 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4670	15041-10000-22568	555 E UNIVERSAL HOLLYWOOD DR 3RD FLOOR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.13776	-118.3584	T 24 TO AN EXISTING APARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING IN THE 3RD FLOOR CORRIDER. PLAN CHECK FOR ENERGY ONLY.  TOTAL SQ. FT. = 347.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4671	13041-10001-11302	2103 W 78TH ST	90047	8	099B189   293	6017021024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	33.96919	-118.31579	Removal of one module and downsizing of inverter.    07/26/13Original Description: PV1 - PLAN CHECK FOR NEW 4.578KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING TRANSFORMERLESS INVERTER. PERMIT INCLUDES SERVICE PANEL UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4672	16041-10000-30425	7120 N BELLAIRE AVE	91605	2	183B161   155	2324021012	[Q]RD1.5-1, [T][Q]RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Apartment			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.19983	-118.40929	PC FOR A FIRE ALARM SYSTEM FOR A NEW 4-STORY 29 UNIT APARTMENT BUILDING. SCOPE INCLUDES 114 FA DEVICES, AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4673	13041-10000-27136	738 E BROOKS AVE	90291	11	111B145  1292	4239013027	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	33.99733	-118.46493	PV1.  Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel.  1 transformerless inverter: Power-One PVI-3000-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4674	14041-20000-03328	7722 N RESEDA BLVD	91335	12	189B125   819	2102021039	R3-1, RD5-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.21126	-118.53586	(($0 permit fee due to senate bill 1222 from 2012))pv2 commercial rooftop photovoltaic system. total system size 48.6kw AC using 5 central inverters. 2 services, one is 120/240 delta 4w connected, the second is 120/240 single phase.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4675	15041-10000-07414	1200 S CLUB VIEW DR 7TH FLR-7 NORTH	90024	5	135B157   112	4327024***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.06748	-118.42481	TI FOR A HIGH RISE BUILDING. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4676	14041-20000-33553	5815 W SUNSET BLVD Suite 402	90028	13	147A191    49	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.09822	-118.31613	Plan check for energy only. TI to existing office in 4-story building. New receptacles and lighting (incl. emergency). 1,819sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4677	17041-10000-11983	11111 W SANTA MONICA BLVD STE 850	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	04/13/2017 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC for T24 only. TI to existing office space. PC for new lights, controls and receptacles. Total affected area is 1621sqft. Building# 17016-10000-08820	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4678	11041-10000-15974	18514 W PLUMMER ST	91324	12	198B125    91	2763035009	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.2426	-118.53707	T.I.  Existing 7-11.  Renovating the light fixtures in the retail area only.  Replacing light fixtures with LED's.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4679	13041-10000-32610	222 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.05621	-118.25318	T24 ENERGY PC FOR 2 OUTDOOR POLE LIGHTS IN THE EXTERIOR COURTYARD. PERMIT TO BE PULLED AT ELECTRICAL PC COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4680	15041-10001-25858	5519 W HOLLYWOOD BLVD	90028	13	148-5A193 132	5544005002	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.10188	-118.31005	09/30/2016 Changes to an approved set of plans. Changes include removed existing Air Conditioning units and add new Air Conditioning units to roof. Changes apply to delta 2 only. ((((((CHANGE OF USE FROM RETAIL TO RESTAURANT.  SERVICE UPGRADE TO 600 AMPS.  PLAN CHECK FOR POWER AND ENERGY. NEW PANELS NEW CIRCUITS.))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4681	19041-20000-04539	8762 N CORBIN AVE	91324	12	195B117   156	2783025095	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.22956	-118.5621	PC FOR T-24 ONLY FOR RETAIL TI , SCOPE OF WORK AREA 1750 SQFT. BUILDING PERMIT # 18016-20000-37035.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4682	19041-10000-53147	2257 S COLBY AVE	90064	11	123B153   329	4260015029	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	10/01/2020 12:00:00 AM		Permit Finaled	08/17/2021 12:00:00 AM	ADDRESS	34.03461	-118.44398	T-24, ENERGY PLAN CHECK ONLY. SCOPE INCLUDES NEW SKYLIGHT, NEW PANELBOARDS,CIRCUITS AND HVAC;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4683	19041-20000-02228	10118 N WOODWARD AVE	91040	7	204B193  1207	2559024015	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.25291	-118.30692	Plan check for PV roof mounted system, system size: 10.80KW DC, 7.6KW AC with 30 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4684	14041-20000-07576	5732 N WILLIS AVE	91411	4	174B149   434	2244017006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.1749	-118.45504	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4685	15041-10000-16622	2716 W OLYMPIC BLVD # 104-105	90006	10	129B197   223	5078010028	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.05243	-118.29218	TI-24 TO AN (E) RESTAURANT BUILDING. NO CHANGE OF USE ADDIND NEW LIGHTING. PC FOR ENERGY AND EMERGENCY LIGHTING ONLY. TOTAL SQ. FT. 1845 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4686	10041-10000-01848	380 W WORLD WAY 2ND LEVEL	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	03/12/2010 12:00:00 AM		Permit Finaled	07/11/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	TEMPORARY RELOCATING ELECTRICAL DISTRIBUTION FEEDERS AND CONDUITS FOR THE TBIT TERMINAL; AS IT IS NOW, ALL EXISTING FEEDERS AND CONDUITS ARE UNDERGROUND AND WILL BE ABONDONED; THIS TEMPORARY RELOCATING OF THE FEEDERS AND CONDUITS WILL BE UNTIL THE NEW TBIT CONCOURSES ARE BUILT AND  THESE TEMPTORARY INSTALLATIONS WILL BE REMOVED. NO NEW ELECTRICAL EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4687	19041-20000-50293	110 E 9TH ST 7th Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TI to commercial tenant spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4688	19041-10000-18032	9090 N GLENOAKS BLVD	91352	6	195B173    53	2408005021	[Q]C2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Issued	05/14/2019 12:00:00 AM	ADDRESS	34.23414	-118.37067	Remove HID fixtures and replace with new LED fixtures (Outdoor only)  - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4689	16041-20000-38376	12700 W VENTURA BLVD 1st Floor	91604	2	162B161    29	2384022049	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	Yes	1439.01	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.14449	-118.40998	TI to (E) commercial office building 1st floor conference room and open office space.  New lighting system in the conference room and new workstations with controlled receptacles in the open office.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4690	11041-20000-01318	818-838 E 29TH ST	90011	9	118-5A207 333	5128015052	(T)(Q)R3-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Apartment			01/21/2011 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.01762	-118.26081	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4691	18041-10001-16557	4121 W SANTA MONICA BLVD	90029	13	145-5A201 370	5429002035	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	34.09205	-118.28241	(This is plan check only, permit is covered under master) DELTA 1 CHANGES TO APPROVED PLANS. CHANGING THE TWO EXISTING SERVICES FROM 2,500AMP & 1,600AMP TO TWO 1,600AMP SERVICES. CHANGES TO T-24, REMOVING AND RELOCATING EV CHARGES & OTHER MINOR CHANGES.<<<<PLANCHECK FOR POWER AND ENERGY. NEW 3 STORY MIXED USE BUILDING WITH 2 LEVELS OF PARKING.  41 UNIT APARTMENTS PLUS COMMERCIAL ON THE FIRST FLOOR.BUILDING PERMIT#  15010-10003-03531>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4692	12041-20001-27779	630 W 6TH ST 1st floor	90017	14	129A209   260	5144005***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.04916	-118.25624	dELTA 1 CHANGES TO APPROVED PLANS ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4693	17041-20001-20126	18936 W BESSEMER ST	91335	3	177B121   564	2128014013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM			PC Approved	06/25/2017 12:00:00 AM	ADDRESS	34.18076	-118.54622	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.10.4kW ungrounded system. (30) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4694	18041-10000-10570	11677 W SAN VICENTE BLVD 101	90049	11	132B145   518	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Issued	04/20/2018 12:00:00 AM	ADDRESS	34.05404	-118.46492	PLAN CHECK FOR T24 ONLY, CHANGE OF USE FROM RETAIL TO BEAUTY SALON AND TENANT IMPROVEMENT. INSTALL NEW LIGHTS  AND RECEPTACLE USING EXISTING PANELBOARD IN THE SPACE. TOTAL AREA: 841 SQ.FT((B# 18016-10000-08735))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4695	15041-20002-40188	6256 N TOPANGA CANYON BLVD Building B	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	[5/4/16 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGE OF MODULE TYPE TO JA SOLAR JAP6-72-350. CHANGES TO ROOF LAYOUT]]]0$ permit fees due to senate bill 1222Plan check for a PV2 roof-mounted PV system. System size 56 kWac and consists of (2) inverters, (1) load center, and (228) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4696	16041-10000-44412	1313 W SEPULVEDA BLVD	90501	15	042B193   827	7347018096	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	33.81424	-118.30074	NEW CORE AND SHELL FOR FUTURE RESTAURANT AND RETAIL. PC FOR POWER AND ENERGY. NEW 1000A SERVICE. PROVIDING COMMON AREA POWER AND SUPPANELS WITH MINIMAL LOAD FOR FUTURE TENANTS. PROJECT IS LOCATED IN METHANE HAZARD SITE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4697	18041-10000-23316	1055 N VIGNES ST	90012	14	133-5A217  38	5409015919	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.06016	-118.23392	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4698	14041-20001-02603	5548 N IRONDALE AVE	91367	3	174B109   509	2151033084	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	ADDRESS	34.17153	-118.58527	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4699	17041-20000-39712	11335 N HERRICK AVE	91331	7	210B157    40	2534005025	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.2761	-118.42036	10.08$ permit fees due to senate bill 1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4700	17041-20001-37577	8755 W YATES ST	91040	7	204B189   414	2546002019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM			Reviewed by Supervisor	10/25/2017 12:00:00 AM	ADDRESS	34.25675	-118.32433	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) with AC coupled battery battery backup system on SFD.5kW unground pv system. (20) 300W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4701	14041-10000-21369	2630 N HARLESDEN CT	90046	4	153B173    14	5569002003	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.11959	-118.36882	Plan check for power and energy. ADDITIONAL PLAN CHECK FEES paid on supplemental. ADDITION TO (E) SFD STRUCTURE. New service and panels.  BLDG#12010-10000-02235.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4702	12041-20000-22279	6420 W WILSHIRE BLVD #240	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.06365	-118.36922	New lighting and receptacles for an existing office space in a high-rise building, STE # 240.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4703	14041-10000-02713	13343 W WENTWORTH ST	91331	6	195B157  1004	2627006024	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.22814	-118.42367	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH 200A MAIN SERVICE PANEL. 3 STRINGS OF (10) MODULES. 7.5kW DC SYSTEM, WITH (30) MODULES, (1) FRONIUS #IG PLUS 7.5 INVERTER, (1) COMBINER BOX. WORK DONE ON STANDARD CENTRAL INVERTER PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4704	14041-20000-10994	10911 W RIVERSIDE DR	91602	4	165B173    52	2423009048	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Mid-Town North Hollywood		1432.00	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.15243	-118.36809	Roof mounted PV system on 2-story building.  Three SMA SB11000TL-US transformerless inverters, 132 Canadian Solar CSGX-305M pv modules.  PV system size 40.26KWdc.Note: Permit fee $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4705	14041-20000-32977	17145 W VENTURA BLVD UNIT A	91316	5	171B133   703	2258012025	(Q)P-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.16066	-118.50709	RETAIL SPACE. NEW LIGHITNG. PC FOR T24 ENERGY ONLY. TOTAL AREA 710 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4706	14041-10000-31434	810 E PICO BLVD	90021										Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			Reviewed by Supervisor	01/09/2015 12:00:00 AM	ADDRESS	34.03119	-118.25079	Plan check for a new fire alarm system consisting of (161) devices, and (1) FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4707	15041-20000-25069	4821 N LANKERSHIM BLVD	91601	2	168B173   395	2353025048	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.15818	-118.37082	Plan check Title 24 only for T.I. in existing space.  Total indoor area: 2200 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4708	18041-10000-09027	225 S MESA ST	90731	15	018B201   791	7455001015	[Q]RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	33.74194	-118.28583	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4709	12041-10000-09719	1451 S HI POINT ST 1-8	90035	10	129B173   623	5068012034	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			04/27/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.05036	-118.36931	Two story condo, 8 units, 23 devices and one panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4710	19041-20000-01488	12200 N CATENIA DR	91344	12	216B133   151	2609023028	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.29091	-118.49948	pv1install roof mounted pv system sized 15.120KW AC interconnected with msp plus battery (1) 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4711	12041-10000-22814	2220 S AVENUE OF THE STARS	90067	5	129B161    53	4329003***	R4-1L-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM			Corrections Issued	09/25/2012 12:00:00 AM	ADDRESS	34.05241	-118.40939	T.I. to existing high rise building on partial of ground floor and basement floor.  Additional load to emergency system.  No changes in lighting.  Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4712	17041-10000-42238	5302 N CLEON AVE	91601	2	171B173   296	2416007009	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.16718	-118.36845	Plan check for a new fire alarm system with (1) Fire alarm panel and (50) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4713	17041-30000-32548	633 W 5TH ST 18th Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Pla check for Title 24 only in existing high-rise building 18 Floor office area T.I. . Total newly connected load less than 400A. Total area: 20811 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4714	16041-10000-28896	7344 W APPERSON ST	91042	7	204B197   858	2558021032	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.25579	-118.29241	Plan check for T-24 only.  Remove outdoor HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4715	19041-20001-02451	2282 N MANDEVILLE CANYON ROAD	90049	11	138B133   487	4493004011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM			PC Approved	06/28/2019 12:00:00 AM	ADDRESS	34.0772	-118.50001	EXPEDITE FEE PER CUSTOMER REQUEST. PV1, INSTALLING 20.2 KWDC ROOFMOUNTED GRID TIED PV SYSTEM WITH 20.3 KWH ENERGY STORAGE SYSTEM. SCOPE INCLUDES 56 MODULES WITH 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4716	19041-20001-44939	6411 S BROADWAY	90003	9	105B201  1325	6005001002	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.10	Electrical	Electrical	Apartment			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Issued	12/02/2019 12:00:00 AM	ADDRESS	33.98101	-118.27849	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF INTERCONNECTION TO MAIN SERVICE. ____________________________________________PV1 PLAN CHECK FOR NEW 9.9 KW DC/8.415 KW AC PV SYSTEM. SCOPE OF WORK CONSISTS OF (30) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER, AND A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4717	13041-10000-12050	4051 S ALAMEDA ST	90058	9	115-5A215  65	5117021020	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM			Reviewed by Supervisor	05/31/2013 12:00:00 AM	ADDRESS	34.00871	-118.23969	PLAN CHECK POWER AND ENERGY FOR NEW INDUSTRIAL BUILDING WITH 2000A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4718	19041-10000-01895	12864 W FOOTHILL BLVD	91342	7	219B161   309	2514002***	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Issued	01/16/2019 12:00:00 AM	ADDRESS	34.29319	-118.41527	REMOVE HID INDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4719	12041-10000-05237	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	33.95466	-118.38556	Per applicant request. Plan check for new installation of two electrical vehicle chargers and new subpanel. EV  charger located in parking lot area.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4720	15041-20000-29267	5246 W LOS GRANDES WAY	90027	4	153B193   402	5588021033	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.11204	-118.305	PV1. ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 9.3 KW.(32) MODULES-SUNPOWER SPR-327NE-WHT-D MODULES(2) INVERTERS-PVI-3800-OUTD-US-A 240V INVERTER AND PVI-5000-OUTD-US-A 240V INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4721	12041-20000-16811	11301 W PICO BLVD 109	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			Corrections Issued	07/19/2012 12:00:00 AM	ADDRESS	34.03517	-118.43924	"Resubmit for lost plans.  T.I. to existing retail space inside ""BEST BUY"".  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-14864"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4722	19041-10003-01293	961 S GRETNA GREEN WAY	90049	11	129B145   957	4264023016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.0466	-118.47066	06/24/19Changes to an approved set of plans, changes include the revisions in clouded areas. Revisions include the removal of optional generator. ________________________________________________PLAN CHECK ONLY. DELTA 1 CHANGES TO AN APPROVED SET.  SCOPE OF WORK INCLUDES THE SINGLE LINE REVISION TO INCLUDE THE CONNECTION OF AN EXISTING GENERATOR( UNDER SEPERATE PERMIT). ________________________________________ Original Scope of Work : (PLAN CHECK FOR ROOF MOUNTED 7.6KW PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 29 MODULES USING P400 OPTIMIZERS AND 2 13.5KWH AC BATTERIES(TESLA POWER WALLS) )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4723	17041-10000-24159	11611 W HART ST	91605	2	183B169   191	2320001023	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.19768	-118.38506	Remove HID fixtures and replace with new LED fixtures - T 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4724	17041-10000-34318	8803 1/2 S FIGUEROA ST	90003	8	096A201   156	6038006037	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	PIN	33.95696791	-118.28302568	PC FOR PV SYSTEM USING 50 MODLES AND CENTRAL INVERTER RATED 11.4KW AC. INTERCONNECTED WITH A 200A SERVICE WITH DERATED MAIN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4725	12041-10000-27906	10840 W NATIONAL BLVD	90034	5	123B157  1152	4254008003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	PIN	34.02994066	-118.42137081	INTERIOR TI FOR CHASE BANK IN AN EXISTING ONE STORY BUILDING. REPLACE PORTION OF STOREFRONT WITH NEW. NEW EXTERIOR WALL OPENINGS(2), EXTERIOR WALK-UP ATM ABD (1) PACKAGE RECEIVER (NIGHT DROP).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4726	12041-10000-19214	1318 W 185TH ST	90248	15	060B197   157	6109023046	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	33.86272	-118.29727	Plan check new roof mounted 4.58KW photovoltaic system (Sunpower tranformerless inverter) for single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4727	18041-20000-19115	8403 N FALLBROOK AVE	91304	12	192B097   579	2005002014	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.22129	-118.62628	Plan check for Title 24 only. Project site is a portion of the ground floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 1,286 sq. ft.Note: Building application has been generated under 18016-10000-09563	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4728	19041-10000-47829	2712 S CAROLINA ST	90731	15	009B197  1003	7465014029	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	33.7194	-118.2905	[EPLAN] RELOCATION OF AC DISCONNECT.$0 FEES DUE TO AB1414 AND SENATE BILL 1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4729	10041-10000-16871	1321 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05129	-118.22464	Solar voltaic system installed on the roof of the building.  Consists of  11  modules,  11  A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4730	18041-10000-37480	6300 W WILSHIRE BLVD 12th Flr	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.06319	-118.36591	Tenant Improvement in existing office area on portions of the 12th Floor. T-24 Energy Only. Building Permit: 18016-10000-22327	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4731	11041-10001-00016	532 S WESTERN AVE	90020	10	135B193   785	5503019005	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM			PC Approved	01/06/2011 12:00:00 AM	ADDRESS	34.06439	-118.30891	TI IN AN EXISTING COMMERCIAL SPACE.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.  PERMIT WAS ISSUED UNDER 11041-90000-00016.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4732	17041-20000-39624	9841 N AIRPORT BLVD 3rd flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Issued	11/22/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4733	14041-20000-31545	6344 N TOPANGA CANYON BLVD UNIT 1010	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	T. I. FOR RESTAURANTPART OF WESTFIELD DEVELOPMENT. FULL PLAN CHECK FOR POWER AND ENERGY. ASSIGN TO ANTHONY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4734	18041-20000-36264	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			PC Info Complete	09/21/2018 12:00:00 AM	ADDRESS	34.06307	-118.2	Plan check for Title 24 only in existing space T.I. in Clinical Science Center women restroom remodel. Total area: 302 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4735	16041-10001-18694	12475 BLUFF CREEK DR	90094	11	102B161  1149	4211010059	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	PIN	33.97754762	-118.40825973	CHANGE TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 CHANGE. CHANGE FEEDER TO CEW-1. NOW BEING FED FROM E1-P2HA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4736	19041-20000-48232	7306 N INDEPENDENCE AVE	91303	3	186B109   925	2112016002	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	Apartment			11/21/2019 12:00:00 AM			PC Info Complete	03/04/2020 12:00:00 AM	ADDRESS	34.20309	-118.59048	FULL PLAN CHECK FOR A NEW 800A, 240/120V SERVICE. SCOPE OF WORK INCLUDES 2 DISTRIBUTION BOARDS THAT CONNECT TO 13  SUBPANELS AND 1 MOTOR.  TOTAL AFFECTED AREA IS 7563 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4737	19041-10000-21070	138 W 115TH ST	90061	15	084B201    51	6087005006	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	33.92997	-118.27536	PV1. ROOFMOUNTED SYSTEM SIZE OF 3.66 KWDC AND 3.32 KWAC, (12) MODULES WITH OPTIMIZERS(P320), (1) INVERTER(SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4738	13041-10000-21693	380 W WORLD WAY 6C2-11	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	PIN	33.94461393	-118.39808495	PLAN CHECK FOR POWER AND ENERGY. FIRST TIME TENANT AT BRADLEY WEST INTERNATIONAL TERMINAL. LAXSUL. 3148 SQUARE FEET ON THE 6TH FLOOR. fire alarm variance has been filed 9/19/2013	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4739	11041-20000-27364	8327 N TAMPA AVE	91324	12	192B117   688	2783001029	C2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.22116	-118.55381	Replace existing meter section with new 6 meter section.  Existing overhead pull box.  All equipment and installations except for the 600 ampere 6 meter section are existing.  The new equipment is to be series rated for not less than 42000 amperes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4740	19041-10000-22833	2905 W EXPOSITION PL unit 5	90018	10	117B185    13	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.02038	-118.3277	Plan check for a 3KW AC/ 2.6KW DC PV2 roof mounted system with (1) inverter and (8) modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4741	16041-20000-35144	9350 N DE SOTO AVE	91311	12	198B109    80	2748002071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.2406	-118.58834	permit fee $0.00 by state senate bill no. 1222PV2 ROOFMOUNTED (172 KW)  AND  ( GROUNDMOUNTED SYSTEM  + EV CHARGERS ON SAME PLANS[ PLANCHECK # 16041-20000-35160 ) ON SAME PLANS.  FEES FOR ROOFMOUNTED SYSTEM ONLY ( 1 OF 2 )SYSTEM SIZE: 398 KW DC. (1156) SW 345 MODULES(2) 23 KW SOLECTRIA PVI(4) 28 KW SOLECTRIA PVI(5) 36 KW SOLECTRIA PVI	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4742	15041-20001-30646	20740 PLUMMER ST	91311	12	198B109    48	2748002032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	PIN	34.24217305	-118.58551034	11/02/2015 Changes to an approved set of plans. Changes include the replacement and relocation of a panel and the addition of (1) new panel. No changes have been done to the lighting. *****Previous Work Description*****Titlw 24 plan check only.  Total area = 2,700 sq. ft.   T.I. to existing warehouse space.  New lighting and receptacles.  Location is not hazardous area per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4743	18041-10000-40829	2021 W SAN FERNANDO ROAD	90065	1	148-5A215  51	5442004008	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Closed	12/08/2022 12:00:00 AM	ADDRESS	34.10202	-118.23676	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4744	16041-20000-07086	10959 W KINROSS AVE	90024	5	132B149    99	4363025001	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.06012	-118.44693	Plan check for energy only. TI to restaurant. New lighting (emergency lighting is existing). 2,600sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4745	10041-10000-07946	2050 S CENTRAL AVE 2	90001	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	PIN	34.02258561	-118.25158988	CHANGE OF USE RETAIL TO MEDICAL (DENTAL) OFFICE. THIS PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4746	12041-10000-13737	6801 W HOLLYWOOD BLVD #109	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	"TI IN AN EXISTING RETAIL STORE IN THE MALL.  UNIT # 109, ""CARMEN STEFFENS"".   PLAN CHECK FOR T-24 ENERGY ONLY.  PERMIT FEES ARE UNDER INSPECTION FOR NEW CIRCUITS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4747	11041-10000-18216	11916 W LINDBLADE ST	90230	11	108B161   184	4218008009	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.10	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	33.99486	-118.41504	NEW ROOF-TOP PHOTO-VOLTAIC SYSTEM FOR A SINGLE FAMILY RESIDENCE.  MODIFICATION HAS BEEN FILED TO USE ENPHASE INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4748	17041-20000-28632	614 S KENMORE AVE	90005	10	135B197  1102	5502028022	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	PIN	34.06293583	-118.29625531	ti to first time tenant  dental office.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4749	19041-20000-36734	5727 N CANOGA AVE BLDG 2	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.17529	-118.5978	PV2 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING APARTMENT BUILDING #2. SYSTEM SIZE IS 16.56 KW DC/15.229 KW CEC AC. SCOPE OF WORK CONSISTS OF (46) PV MODULES, A 100A PANEL, A 3.8 KW INVERTER, AND (2) 5 KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4750	13041-10000-15688	2535 S LONGWOOD AVE	90016	10	123B181   904	5049008032	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			06/14/2013 12:00:00 AM			Corrections Issued	06/14/2013 12:00:00 AM	ADDRESS	34.03301	-118.34936	Removal of unit and corridor lights and replacement with new compact fluorescent fixtures in existing 2 story apartment building.  New outdoor metal halide lights on front of building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4751	16041-10001-44261	11167 W COHASSET ST	91352	2	186B173   461	2315014026	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM			PC Approved	01/11/2017 12:00:00 AM	ADDRESS	34.20674	-118.37439	SUPP. FOR EXPDITED FEES.Roof mounted solar system installation single family home. Installing new central inverter rated at 10.0 Kw with 41 modules.PANNELS LOCATED ON THREE DIFFERENT BUILDINGS. VERFIY BLDG PERMITS FOR ALL BUILDINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4752	13041-10000-23580	1801 S CENTURY PARK EAST 21ST	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.06201	-118.41537	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING FOR THE 21ST FLOOR OF A HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4753	17041-10001-45515	4826 N BILOXI AVE	91601	4	168B177   412	2420006017	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	34.15853	-118.35812	Supplemental for PV expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4754	14041-20000-03829	9507 N BECKFORD AVE PV1	91324	12	198B117    62	2762011014	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.24308	-118.5516	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH MAIN SERVICE PANEL. SYSTEM SIZED @ 8.75 kW DC, AND IS TRANSFORMERLESS, WITH (2) POWER ONE INVERTERS; PVI-3800-OUTD-US-A, PVI-3800-OUTD-US-A (35) MODULES ET-P660250BB, (1) LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4755	11041-20000-04312	11922 W VALERIO ST	91605	6	186B165   546	2317015014	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	03/15/2011 12:00:00 AM		Permit Finaled	04/25/2011 12:00:00 AM	ADDRESS	34.20472	-118.39294	Plan check T24 Energy for Interior tenant improvements in office spaces. Permit for new panel and branch ckts	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4756	18041-30000-46933	1058 S HOLT AVE	90035	5	132B173   618	4332025020	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	03/23/2021 12:00:00 AM	ADDRESS	34.0576	-118.37816	NEW FIRE ALARM SYSTEM TO A LOW RISE APARTMENT BUILDING. (1) FA PANEL AND (120) FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4757	19041-10000-47323	12325 W ERWIN ST	91606	2	177B165   292	2333009084	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.18318	-118.40173	$0 fee per AB1414. [EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 21.120KW DC/ 22.8KW AC, WITH 2 SOLAREDGE CENTRAL INVERTER (SE11400-US), 66 OPTIMIZERS (P400), 66 MODULES (SUNPOWER 3320W), 1 DISTRIBUTION PANEL AT 125A, AND A MAIN SERVICE PANEL OF 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4758	11041-10000-11838	1000 N WESTERN AVE	90732	15	021B193   140	7445010041	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	11/18/2011 12:00:00 AM	ADDRESS	33.75242	-118.30869	CHANGE OF USE FROM RETAIL STORE TO A BANK.  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4759	13041-20000-34521	1845 W SAN FERNANDO ROAD	90065	1	148-5A215 107	5442004011	[Q]MR1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	ADDRESS	34.10025	-118.23521	Remove 800 amp service, new 400 amp service for an existing 1-story commercial building.  Load is less than 400amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4760	15041-20001-03102	9825 N BALBOA BLVD	91325	12	201B133   204	2692012033	C2-1VL	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.24953	-118.50261	07/22/2015 Changes to an approved set of plans. Changes are to have plans reflect all field changes. *****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR TACO BELL RESTAURANT.  13450 SQFT, INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4761	15041-10000-28050	736 S LA BREA AVE	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.06115	-118.3442	CHANGE OF USE FROM RETAIL TO RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4762	16041-30000-18170	644 W 2ND ST	90731	15	018B197  1295	7451009018	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	33.7425	-118.29102	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (13) modules and (1) inverter. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4763	14041-10000-26787	200 N NORTH MAIN ST	90012	14	130-5A213   3	5161014901	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.05326	-118.24219	"REPLACEMENT OF FIRE ALARM SYSTEM FOR CITY HALL. 1646 DEVICES AND 6 PANELS.# OF DEVICES PER APPLICANT COUNT.INVESTIGATION FEE WAIVED""COMPLY WITH DEPARTMENT ORDER effective date05/13/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".Payment of investigation fee due at time of permit issuance.""COMPLY WITH DEPARTMENT ORDER effective date05/12/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation. Ifadditional assistance is needed, please call Inspector DENNISHAWKS at (213)485-7166 of GENERAL ENFORCEMENT CENTRAL.  CEIS CaseNumber is 226514.(Created: IMSV7 / 05-12-08)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4764	12041-10000-14476	500 E WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	09/25/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR SPACE 5R (COFFEE BEAN & TEA LEAF) LAX TERMINAL 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4765	16041-10000-20357	1532 W 11TH ST	90015	1	129A203   285	5137020020	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.04726	-118.27438	Installation of new fire alarm system in commercial building.  Total system size = 54 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4766	18041-20000-08384	14332 W VENTURA BLVD	91423	4	165B153   358	2266002054	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.15014	-118.44535	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from yoga-spin studio to medical office/tenant improvement. Total lighting area = 1,479 sq. ft.Note: Building permit has been issued under 18016-30000-03702	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4767	19041-20000-45050	19425 W MARTHA ST	91356	3	174B117   192	2153032021	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.17409	-118.55646	PV1.  Install 12.240 kW DC / 11.027 kW AC roof mounted grid tied PV system.  (34) modules with (2) 6 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4768	19041-10000-45375	9430 N LURLINE AVE	91311	12	198B109   206	2748041034	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	12/15/2020 12:00:00 AM		Permit Finaled	02/21/2023 12:00:00 AM	ADDRESS	34.24131	-118.58401	NOTE: Permit fees are $0 due AB 1414. PV2. Plan Check for PV system. System consists of (174) Modules, (90) P860 optimizers, 66.6K solaredge inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4769	14041-10000-24553	21255 W BURBANK BLVD STE 410	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.17432	-118.59446	PC for power and energy. 4 story building. 4th floor. TI office, ste 410. total area 13907 sq ft. BLDG#14016 70 17817. changes on plan include an addition of an exit sign, T24 clarifications, and clarifying Electrical rm 'B'  equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4770	13041-10000-10832	3937 S BLEDSOE AVE	90066	11	114B157  1000	4214007029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.00766	-118.41955	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM 6.62 KW. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 27 MODULES. CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4771	14041-10000-04468	16800 W LIGGETT ST	91343	12	198B137   466	2687009012	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.23995	-118.49843	PV1, INSTALL 8.25 KW DC ROOF -MOUNTED SOLAR ARRAY ON A HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTER:  SOLAREDGE  SE5000A-US(240)(33) MODULES; RENESOLA JC250M-24/BB.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4772	18041-10000-34832	4625 S HOOPER AVE	90011	9	112-5A211 318	5107010029	RD2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.00128	-118.2523	NEW LUMINAIRES AND WIRING IN RETAIL MARKETPLAN CHECK IS OF TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4773	10041-10001-03200	9060 W PICO BLVD	90035	5	132B169   883	4305007013	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM			PC Approved	08/30/2010 12:00:00 AM	ADDRESS	34.05505	-118.38929	Change the priviously approved plan. Change the lighting and T24. Plan check for T24 and energy. (((((((((demolish one of two buildings on site and build 2-story building as addition to remaining building to house the Eliat  Bakery))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4774	13041-10001-35544	4124 W 59TH PL	90043	8	105B181   432	4003005007	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	33.98607	-118.34735	Expedited RSES plan check per applicant request.{{PV1, Install 3 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (12) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4775	19041-10000-49511	2515 S WESTERN AVE	90732	15	009B189    86	7563016016	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	33.72257	-118.31381	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4776	16041-30000-00495	13224 N MIRA MAR DR	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.31307	-118.40434	Addition of roof mounted solar PV array to existing solar PV system.  Total system size = 7.2 kWac (3 kWac new + 4.2 kWac existing).  Two inverters total.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4777	10041-10000-18364	108 S CROFT AVE 1-6	90048	5	138B173   639	5511014004	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	10/20/2011 12:00:00 AM	ADDRESS	34.07419	-118.37407	METHANE MITIGATION SYSTEM FOR APARTMENT BUILDING. PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4778	16041-20001-08977	3020 W WILSHIRE BLVD	90010	10	132B197    30	5077013038	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	03/29/2016 12:00:00 AM	ADDRESS	34.06165	-118.28725	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM.  FEED IN TARRIF.  SYSTEM SIZE: 168 KW.  BUILDING PLANS TO BE SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4779	13041-10001-34500	4611 S ROMA CT	90292	11	102A149    56	4295004064	[Q]RD1.5-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	33.97167	-118.4583	Expedited RSES plan check per applicant request.{{PV1, Install a 2.65 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[ SUNIVA # OPT265-60-4-1B)] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4780	17041-10002-18139	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Approved	07/21/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC FOR REVISIONS TO APPROVED SET UNDER B. SCOPE INCLUDES CHANGESNEW LUMINAIRE. in the restroomPLAN CHECK ONLY!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4781	12041-10000-11767	133 S LUCERNE BLVD	90004	4	138B189  1121	5515015020	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Expired	07/18/2014 12:00:00 AM	ADDRESS	34.07204	-118.32497	Plan check for new roof mounted Enphase M215 Microinverter photovoltaic system for a single family dwelling located in Methane Buffer zone. PV Modules located on main house and detached garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4782	17041-10000-29209	21629 W DEVONSHIRE ST	91311	12	204B105   216	2722009005	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.2574	-118.60136	PC FOR COMM. SPACE FOR TITLE 24 ENERGY ONLY. INSTALLING NEW CIRCUITS LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA 2322 SQ.FT.THIS IS PLAN CHECK ONLY!!!PERMIT PULLED  UNDER 16041-20001-10878	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4783	19041-20000-53253	3200 S GRAND AVE	90007	9	120A203   240	5122008002	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	09/28/2020 12:00:00 AM		Permit Finaled	07/28/2021 12:00:00 AM	ADDRESS	34.0215	-118.27525	Plan check for power and energy for newly connected load over 400A and new lighting and heat lamps loads. Total general lighing area:15,781 sq ft.  B#19016-20000-36285********Building Work Description******************CHANGE OF USE FROM MANUFACTURING/OFFICE/RETAIL/STORAGE BUILDING TO INDOOR NURSERY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4784	15041-10000-14916	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	Retail area lighting comprising 3579 sq. ft.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4785	17041-20000-07806	2250 S COTNER AVE	90064	5	126B153  1059	4322024011	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Issued	03/10/2017 12:00:00 AM	ADDRESS	34.03816	-118.43819	Plan check for power only. New 600A service for existing commercial office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4786	19041-10001-11434	1400 S ESPERANZA ST	90023	14	118-5A227 286	5191023001	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Public Safety Only			04/05/2019 12:00:00 AM			PC Approved	04/16/2019 12:00:00 AM	ADDRESS	34.01704	-118.20086	PC FOR Gas detection system.SCOPE INCLUDES 1 PANEL (2 12V 55AH) AND 17 DEVICES.  THIS IS PLAN CHECK ONLY PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4787	16041-10000-02271	3919 W BEVERLY BLVD #201, 203	90004	13	138B197   299	5520020008	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.07647	-118.2939	SUBDIVIDE TENANT TO 2 SUITES. TI FOR MEDICAL OFFICE. NEW POWER AND LIGHITNG. PLAN CHECK FOR POWER AND ENERGY. MEDICAL SHALL MEET ART 517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4788	12041-10000-07571	611 S WESTERN AVE	90005	10	135B193   910	5503031006	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.06305	-118.30927	REMODEL OF EXISTING RESTAURANT NEW LOADS ARE LESS THAN 400APLAN CHK IS FOR TITLE 24, PERMIT FEES ARE UNDER INSPECTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4789	18041-20000-30165	24208 S ROSCOE BLVD	91304	12	192B089   197	2017039008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.21937	-118.65432	PV1.  Install 2.835 kW roof mounted grid tied PV system.  (9) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4790	16041-10000-32142	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	Energy plan check for for (7) exsiting  personel restrooms located on the ground level of Terminal-4, LAX airport.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4791	13041-10000-05881	3728 S CRENSHAW BLVD	90018	10	117B185   240	5033001039	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	PIN	34.01889734	-118.33407766	provide new pendant fixtures and power for equipment. relocate lights.TENANT IMPROVEMENT TO EXISTING RESTAURANT  (1424 SF):NEW KITCHEN EQUIPMENT INCLUDING HOOD, NEW FINISHES, LIGHTING, SERVICE COUNTER, NO CHANGE IN USE OR OCCUPANT LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4792	18041-10001-31737	812 N EL ORO LANE	90272	11	129B121   293	4419012024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.05077	-118.54807	EXPEDITED FEEPC FOR ROOFMOUNTED 11.4KVA PV ON SFD SCOPE INCLUDES 3 CENTRAL INVERTER(SOLIVIA 3.8 TL) WITH 36 MODULES(SOLARCITY SC325).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4793	13041-10000-20236	817 N HILL ST	90012	1	135A215   281	5408033003	C2-2D	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.06328	-118.23947	PLAN CHECK ONLY FOR TITLE 24. PERMIT PULLED UNDER SEPERATE APPLICATION NUMBER 13041-10000-11795.***************************************************************************13041-10000-11795 WORK DESCRIPTION: INSTALL (15) RECEPTACLES OUTLETS & (5) LIGHT SWITCHES.  2 OF 2 (13042-10000-08723)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4794	17041-20001-37497	4800 W WILSHIRE BLVD	90010	4	132B185    22	5507030001	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.06182	-118.33508	9/13/2018changes to an approved set of plans.  changes to lighting fixtures and energy calculations.((((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,381 sq. ft.Note: Building permit has been issued under 15016-10000-25090))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4795	19041-20000-14465	925 S ST ANDREWS PL 23	90019	4	132B193   992	5092023004	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			04/19/2019 12:00:00 AM			Reviewed by Supervisor	06/06/2019 12:00:00 AM	ADDRESS	34.05503	-118.31129	PLAN CHECK FOR NEW 4-STORY, 23-UNIT APARTMENT BUILDING 17983 SF WITH GARAGE @ GRADE LEVEL T24 INCLUDED, TOTAL SQUARE FOOTAGE = 13,756SF. NEW 1000A SERVICE, 1000A PANEL, 400A PANEL, 600A PANEL, 150A HP, 80A EVP, 40HP ELEVATOR, AND (23) 100A UNIT PANELS. 4 TYPICAL UNITS.B#19010-10000-04915	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4796	19041-20001-06153	10236 W MOSSY ROCK CIR	90077	5	156B153   196	4382025***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.12205	-118.44372	Expedite per applicant request Plan check for PV roof mounted system, system size: 11.22KW DC with 34 PV Modules and 1 inverter(11.4KW) connected to 225A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4797	19041-10000-22721	9255 N SAN FERNANDO ROAD	91352	6	198B169   128	2631003028	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.23743	-118.39209	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4798	17041-20000-37852	21700 W OXNARD ST #850	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for energy only. TI to existing office suite 850 in high rise building. New lighting (incl. emergency) - 3,097sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4799	17041-20000-40019	9210 N SHOSHONE AVE	91325	12	198B129   313	2766010014	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.23817	-118.51766	PV1.  Install 12.9 kW roof mounted grid tied PV system.  (36) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4800	16041-10001-05128	1647 N MANDEVILLE CANYON ROAD	90049	11	135B137   621	4426001016	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM	ADDRESS	34.06264	-118.49378	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL NEW 12.9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(43) MODULES: SILEVO TRIEX U300 BLACK(2) INVERTERS: ABB PVI 5000&6000-OUTD--US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4801	08041-10003-17061	975 N VENDOME ST 1-36	90026	13	142-5A203 305	5426016003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.01	Electrical	Electrical	Apartment			04/20/2011 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.08417	-118.27465	"Change the priviously approved plan. Addition of HVAC system on the roof. EPC is for power.  ((((((((((((((((((((EPCTi in 36 units appartment building. Electrical plan check is for power and Energy. ( Fee is not included T24 for outdoor and ""House panel"" branch circuits.))))))))))))))))))))))))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4802	10041-10000-05212	2949 W PICO BLVD	90006	10	129B193  1207	5080020029	R4-1VL	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM			Verifications in Progress	07/09/2010 12:00:00 AM	ADDRESS	34.04735	-118.30469	SERVICE UPGRADE TO 800 AMPS. REMOVE EXISTING SERVICE AND REFEED EXISTING TRANSFORMER AND PANELS FROM NEW SERVICE. INSTALL NEW AC UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4803	17041-20000-20249	3515 W HYDE PARK BLVD	90043	8	105B185  1231	4006007036	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			06/15/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	33.98072	-118.33417	new fire alarm system 140 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4804	11041-10000-15340	9850 N MASON AVE	91311	12	201B109   133	2748006033	C1-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.24934	-118.57962	T.I  Existing 7-11.  Replacing 28 light fixtures, using the existing branch circuits, in the retail space only.  Plan check is for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4805	16041-10000-40523	744 E PICO BLVD	90021	14	123A211   127	5132019042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.03202	-118.25256	PC for t24 energy only. revised lighting in a retail tenant. no other work done.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4806	13041-20000-27800	6314 W SANTA MONICA BLVD	90038	13	144B185   728	5533017003	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/09/2013 12:00:00 AM	ADDRESS	34.09058	-118.32723	T24 FOR TI OF EXISTING PAINT SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4807	18041-10000-14536	9145 N OWENSMOUTH AVE	91311	12	198B105   164	2746012020	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.23659	-118.60207	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4808	12041-20000-28849	21350 W NORDHOFF ST #104	91311	12	195B105   365	2779017***	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	34.23523	-118.596	Install lighting and receptacles in remodeled tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4809	16041-20000-03720	11439 N RUBIO AVE	91344	12	213B137   662	2682002013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Refund in Progress	01/05/2017 12:00:00 AM	ADDRESS	34.27845	-118.49699	Plan check for a PV1 roof-mounted PV system. PV system is a 3 kWac addition to an existing 5 kWac system, for a total system size of 8 kWac. PV addition consists of (1) inverter, (13) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4810	16041-10000-44564	11509 N LAUREL CANYON BLVD	91340	7	213B149   396	2613027019	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.27887	-118.45394	PC FOR ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 27750 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4811	16041-20000-23923	411 S CATALINA ST	90020	10	135B197   557	5502012021	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.06673	-118.29556	$0 permit fee due to State Senate Bill SB 1222PV2.  Install 59.8 kW DC roof-mounted PV system.  (176) modules with (4) 10kW transformerless central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4812	11041-10001-19586	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM			PC Approved	10/02/2012 12:00:00 AM	ADDRESS	33.95466	-118.38556	Changes to approved set of plans. Solar panels were relocated and two 250KW inverters were installed in lieu of three smaller inverters. Photovoltaic modules mounted on carports. One inverter will be for future PV installation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4813	14041-10001-14663	5955 W MELROSE AVE	90038	13	141B185   579	5533034012	C4-1XL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM			PC Approved	07/15/2014 12:00:00 AM	ADDRESS	34.08358	-118.33031	Title 24 plan check only.  Total area = 336 sq. ft.T.I. to existing commercial space.Revised lighting to previously approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4814	16041-20000-14225	6570 S WEST BLVD	90043	8	102B185    90	4006020022	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			04/22/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	33.97915	-118.33503	Plan check for a PV2 roof-mounted PV system. System size 100 kWac and consists of (5) inverters, (314) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4815	15041-20000-16747	15025 W SUNBURST ST	91343	6	195B145    37	2651018004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Expired	06/27/2017 12:00:00 AM	ADDRESS	34.23459	-118.45963	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4816	15041-20000-39681	14006 W RIVERSIDE DR FC5-SFC9	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			Corrections Issued	11/25/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	NON-STRUCTURAL T.I FOR (E) RESTAURANT IN MALL FOOD COURT. INSTALLING KITCHEN AND NEW WALK IN COOLER. PC FOR ENERGY ONLY. TOTAL AREA: 510 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4817	18041-10000-33302	9454 N JORDAN AVE	91311	12	198B105    37	2746014018	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.24214	-118.60381	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4818	17041-10001-15398	433 S SPRING ST	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDING 27 NOTIFICATION DEVICES AND 213 MODULES = 240 DEVICES ON EXISTING PANELS ORIGINAL PERMIT Replacement of fire alarm system for 12 story office building core and shell.  Highrise voice evac system.  Total system size = 821 devices + 18 FACP	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4819	16041-10000-28917	10940 W WILSHIRE BLVD 8,12,14,21-FLR	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.05822	-118.4452	PLAN CHECK FOR T-24 ONLY.  INTERIOR TENNANT IMPROVEMENT IN EXISTING HIGHRISE BUILDING,WITHIN CORRIDORS AND ELEVATOR LOBBY ON 8TH, 12TH, 14TH, AND 21ST FLOORS.  INSTALL NEW LIGHTS AND RECEPTACLES USING (E) CURCUITS.(( B# 16016-30000-16128))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4820	11041-10005-23452	20600 W VENTURA BLVD South-1-217	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			04/02/2015 12:00:00 AM			PC Approved	04/02/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	REVISIONS TO PERMITTED SET OF PLANS: EXIT SIGNS AT BOTTOM OF STAIRWAYS; NEW CKTS INCLUDING CKTS FOR CAR CHARGERS; CHANGES ARE CLOUDED AND MARKED DELTA 13  ON THE PLANS((((((((South Building of a New 217 unit Apartment building.  Building Permit is on 11010-10000-019	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4821	13041-10000-25674	6735 N BABCOCK AVE	91606	2	180B161   139	2325002015	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.19304	-118.40685	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING TO MAIN IN A SINGLE-STORY HOME. WORK IS DONE ON A STANDARD MICRO-INVERTER PLAN. SYSTEM SIZE IS 4.25KW DC.  (17) MODULES: TRINA SOLAR #TSM-250-PA05.08(17)ENPHASE-M215-60-2LL-S2X	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4822	19041-20000-37531	6221 N FALLBROOK AVE	91367	3	177B097   248	2039013060	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	34.18316	-118.62362	INSTALL (130) FIRE ALARM DEVICES AND (1) PANEL  FOR COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4823	14041-10000-15271	9601 N OAK PASS ROAD	90210	5	153B157   102	4384005023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.11799	-118.42697	pLAN CHECK for power and energy. BLDG#11014-20000-04530:ADDITION AND REMODEL W/ ATTCHED 3 CAR GARAGE AND 2 OPEN PARKING STALLS,Rebuild 2,058 sqft of fire damaged and add 4,384 sqft floor area and 793 sqft for 3-car garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4824	10041-20000-09129	3709 S TROUSDALE PKWY BASEMENT	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.01851	-118.28672	PLAN CHECK T-24 (GENERAL/EMERGENCY LIGHTING) REMODEL CLASSROOM AT USC MUDD HALL BASEMENT LEVEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4825	13041-20000-35557	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	ADDRESS	34.24138	-118.60168	T24 FOR EXISTING MANUFACTURING. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT. 27,000 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4826	18041-10000-45768	10700 W STAGG ST	91352	2	189B177   698	2409013001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.21195	-118.3641	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 MODULES (QCELL G4.1 305) AND 20 MICROINVERTERS (ENPHASE IQ6-60-2-US).  SYSTEM SIZE IS 6.1KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4827	17041-10000-34998	218 E 12TH ST	90015	14	124-5A209  65	5145028003	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.03651	-118.25803	PC for T24 only for outdoor lighting. Replacing HID fixtures and replacing with new LEDfixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4828	19041-20000-21996	13422 W BASSETT ST	91405	2	183B157   782	2328014017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.19567	-118.42547	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM CONSISTING OF TWO 13.5 KWH TESLA POWERWALLS AND A NEW 200A PANEL TO EXISTING SFD WITH EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4829	17041-20000-31252	21817 W WYANDOTTE ST	91303	3	186B105   847	2111012023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Refund in Progress	10/05/2017 12:00:00 AM	ADDRESS	34.20295	-118.60355	new fire alarm system 53 devices plus new facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4830	12041-10001-03519	9540 N VAN NUYS BLVD	91402	6	201B149   735	2644025901	P-1VL, RD2-1, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			PC Approved	05/08/2013 12:00:00 AM	ADDRESS	34.24411	-118.45004	SUPPLEMENTAL PLAN CHECK TO 12041-1000-03519. CHANGE OF LUMINAIRE TYPES. DELTA CHANGES ARE CLOUDED.  Plan check for T24 Energy/Emergency lighting for City of LA Multipurpose Center. Indoor and outdoor lighting. Building less than 100 occupants.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4831	13041-20000-07652	1624 S ABBOT KINNEY BLVD	90291	11	108B145  1627	4238017031	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	33.98961	-118.46353	Plan check for energy and emergency lighting. Bookstore.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4832	15041-10001-38755	720 E WASHINGTON BLVD	90021	14	121-5A209 107	5131005007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.02762006	-118.25646467	Changes to approved set of plans. Adding 26 new fire alarm devices. and new remote power supply((((Installation of new FA. to an existing apartment building (4 story building). Scope: (1) FA, (3) Control Panels, (1) communication panel, (176) FA devices.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4833	09041-10008-24367	3327 E SABINA ST Bldg B	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			01/19/2012 12:00:00 AM			PC Approved	01/19/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Changes to permitted set of plans. Delta 7 Revision the plans. New Apartment Complex w/ multiple buildings (Bldg B)  2 of 2.  4 typical units, 48 units total.  Permit is for service, distribution, new ckts, busway, panels.  P/C is for Power and energy. Modification to seperate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4834	12041-10001-18770	17037 W DEVONSHIRE ST	91325	12	204B133   170	2695020033	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.25769	-118.5035	Revision to the approved plan. Change the T24 & outdoor lighting. EPC is for T24. ((((((((((Plan check for T24 Energy facade outdoor lighting.))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4835	18041-10000-36171	20437 W DEVONSHIRE ST	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.25741	-118.57899	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM  B OCCUPANCY  TO M. "" ATT STORE "" 595 SQFT.BUILDING PERMIT # 18016-10000-30623"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4836	19041-10000-51347	5627 W FERNWOOD AVE	90028	13	147A193   195	5544030010	R4-2	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	10/08/2021 12:00:00 AM		Permit Finaled	05/12/2023 12:00:00 AM	ADDRESS	34.09604	-118.3119	Full PC for Power and Energy. Scope includes a new 1600A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, 60 100A PANELBOARDS, ONE 15 HP ELEVATOR, ONE 1.2KVA INVERTER, NEW CIRCUITS. TOTAL AFFECTED AREA IS 22405 SQ. FT. ((((((((((((((((((((((((((((((((((((((((((((((((New 6-story (5 story of Type III-A with 1 story of Type IA and basement parking) residential building with offices and 60 permanent supportive housing units per DIR-2017-4872-TOC.   SB 35 PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4837	18041-20000-42760	874 N SANBORN AVE	90029	13	144A201   321	5427009027	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.0879	-118.28335	addition of battery system to an existing pv system.(1) 5KW battery LG Chem	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4838	10041-10000-08570	10000 W FOOTHILL BLVD	91342	2	210B181   168	2550014002	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	09/13/2010 12:00:00 AM	ADDRESS	34.27275	-118.34595	Ti in a church. Add a mezzanine to the assembly room. Plan check for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4839	12041-20002-25405	12161 W SATICOY ST	91605	6	186B165   215	2307015006	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Issued	03/25/2014 12:00:00 AM	ADDRESS	34.20863	-118.39866	(((3/25/2014- CHANGES MADE TO APPROVED SET, ALL STRING BRANCHCIRCUITS MOVED UNDER ONE  1' CONDUIT))(((3/18/2014- CHANGES MADE TO APPROVED SET HOWEVER NO PERMIT IS REQUIRED.  THIS IS A PLAN CHECK ONLY.)))New rooftop pv system for an existing single family residence.   System is ungrounded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4840	14041-20001-18129	11036 N BABBITT AVE	91344	12	210B133   519	2696007005	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	ADDRESS	34.2712	-118.50966	PV1.  Install 10.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4841	16041-10000-32576	3201 N LACY ST	90031	1	142-5A221 272	5205002902	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM			Reviewed by Supervisor	10/13/2016 12:00:00 AM	ADDRESS	34.08349	-118.21854	TEMPORARY POWER FOR PORTABLE BUILDINGS ONLY.  APPLICANT NOTED THE BUILDINGS ARE PRE FABRICATED AND  STATE APPROVED.( THE APPLICATION 13041-10000-34763 HAS BEEN EXPIRED WITH THE SAME SCOPE FOR THIS BUILDING)BUILDING PERMIT # 13014-10000-04943.  RENOVATION/REMODEL OF (E) ANIMAL CARE FACILITY  ABOUT 5000 SQ ADDITION; NEW PARKING DESIGN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4842	18041-20000-38211	1800 S CENTURY PARK EAST STE 430	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.06244	-118.41523	Plan check for Title 24 only in existing  high-rise building office T.I. Total area: 1278 sq ft. 18016-10000-21194	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4843	17041-20000-00339	13413 N BRADLEY AVE	91342	7	225B141   126	2501002002	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.31561	-118.47321	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (17) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4844	18041-10000-43864	1320 W JEFFERSON BLVD	90007	8	120B197   678	5040019007	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			11/15/2018 12:00:00 AM	09/02/2020 12:00:00 AM		Permit Finaled	12/27/2023 12:00:00 AM	ADDRESS	34.02515	-118.29521	Full plan check for a new 6-story, 130-unit with 10% affordable housing apartment over 2 level of subteranean parking. Scope include a 2500-Amp service 277/480V.Expedite per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4845	19041-10002-01861	1101 S HARBOR VIEW AVE	90732	15	015B193   956	7459003014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	33.73448	-118.30888	Plan check for a lost set of plans for PV system. Note: Permit is paid under PCIS#19041-10000-01861	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4846	15041-10000-00043	1004 N SAN FERNANDO ROAD	90065	1	145-5A217 203	5453004028	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.09172	-118.22811	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 7120 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4847	19041-20000-41060	11881 W TERRA VISTA WAY #114	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4848	18041-10000-00196	904 S TREMAINE AVE	90019	4	132B185   411	5090003014	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Issued	03/08/2018 12:00:00 AM	ADDRESS	34.05847	-118.33661	Plan check for storage battery system 13.5kWH in SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4849	19041-10000-11968	13130 W BURBANK BLVD	91401	4	174B157  1137	2345005028	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.17191	-118.41936	Replace fluorescent troffers with new LED retrofit kits - BLD #2, Indoor only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4850	15041-10000-13708	8000 N DEERING AVE	91304	3	189B105   177	2109017029	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.2157	-118.59491	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH LED FIXTURES. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4851	10041-10000-11659	753 S VERMONT AVE	90005	10	132B197   389	5094011003	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			06/18/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.05827	-118.29187	CHANGE OF OCCUPANCY FROM DONUT SHOP TO DENTAL OFFICE WITH INTERIOR NON STRUCTURAL TENANT IMPROVEMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4852	11041-20000-01597	555 W 5TH ST 10th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	energy plan check 10th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4853	11041-20000-18769	1541 N MONACO DR	90272	11	132B133   113	4425033007	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2011 12:00:00 AM			PC Approved	01/06/2012 12:00:00 AM	ADDRESS	34.05892	-118.50053	Plan check power for existing house addition with new 600A service. Permit under #10014-10000-03017	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4854	13041-10000-02689	3668 S 3RD AVE	90018	10	120B189  1612	5042005023	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.02092	-118.31998	PV1 for 2 story house via microinvertors. System size 3.024KW. [Microinverter: Enphase Energy. Model number: M215-60-2LL-S22] and [Module: REC Model number: REC 245 PE]. 14 microinverters and modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4855	11041-10000-18682	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM	01/30/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	Core & Shell for a 3-story commercial building, with new 34.5KV : 4160V service.   Plan check is for power and T24 for electrical rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4856	13041-10000-33551	15822 W ARMINTA ST	91406	6	189B141   164	2206002032	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Expired	12/28/2015 12:00:00 AM	ADDRESS	34.21378	-118.47807	Remove HID light fixtures and replace with new fluorescent fixtures in work space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4857	19041-10000-36785	7822 N GENESTA AVE	91406	6	189B133   699	2204021009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.2128	-118.5039	[E-PLAN]PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL EV CHARGING INVERTER AND POWER OPTIMIZERS. (32) MODULES, (32) OPTIMIZERS, (1) 7.6 KWAC EV CHARGING INVERTER. TOTAL SYSTEM SIZE IS 7.6 KWAC /  10.720 KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4858	15041-20000-16806	6316 N TOPANGA CANYON BLVD B 1160	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	TI to existing commercial building (retail). First time tenant. Plan check for power and energy. Adding new service. Adding new lighting . Total sqft. 1,726.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4859	14041-20000-32418	7051 N HAYVENHURST AVE	91406	6	183B137   530	2225003009	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.19893	-118.49257	PC FOR POWER AND ENERGY. EXISTING BUILDING CONVERT TO RETAIL/ SHOWROOM WITH ACCESSORY AUTO SERVICE AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4860	15041-10000-41241	3268 W SLAUSON AVE	90043	8	108B185   923	4005005027	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	33.98884	-118.32949	T-24, TI TO THE FACADE OF AN (E) RESTAURANT, POPEYES. SCOPE OF WORK INCLUDES NEW OUTDOOR LIGHTING ONLY. TOTAL SQ. FT. 2400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4861	16041-10001-04767	8372 W 3RD ST	90048	5	138B173   843	5511031022	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.0728	-118.37249	04/04/16Changes to an approved set of plans. Changes include replacing/adding lighting fixtures. Lights are being replaced with track lights. Plans to reflect what is on the field. NOTE: Permit pulled under PCIS#16041-10000-04767((((T-24, TI TO AN (E) RETAIL STORE, SCOPE OF WORK INLCUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. F.T 1225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4862	12041-10000-24455	530 S SPRING ST	90013	14	129A211   182	5149036010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			PC Approved	10/19/2012 12:00:00 AM	ADDRESS	34.04656	-118.25019	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR 6TH FLOOR TENANT IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4863	17041-10000-10689	915 E 41ST PL	90011	9	115-5A209 410	5115024004	RD2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.0085	-118.25958	PC FOR PV SYSTEM ROOF TOP. SYSTEM USES 22 MODULES AND 6KW INVERTER	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4864	16041-10000-15553	8426 W 3RD ST	90048	5	138B173   812	5511032041	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.07289	-118.3741	PLAN CHECK FOR TI 24 ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS, NEW RECEPTACLES AND ONE NEW 100 AMP PANEL. TOTAL AFFECTED AREA IS 60 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4865	18041-10000-36691	3550 S MCCLINTOCK AVE	90089	9	120B197   779	5039012029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.02264	-118.28849	TI IN AN EXISTING COMMERCIAL AREA IN THE LOCKER ROOMS.TITLE -24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4866	15041-10001-00619	13907 W DAVENTRY ST	91331	7	207B153   325	2618003020	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2015 12:00:00 AM			PC Approved	01/30/2015 12:00:00 AM	ADDRESS	34.26558	-118.43589	Supplemental application for expedite feeInstallation of new roof mounted solar PV array.  Total system size = 12 kVacRestamp for permit issued 14041-10000-23566 (original stamped set lost)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4867	16041-10001-45802	1124 S SAN JULIAN ST	90015	14	124-5A211 188	5145025002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.03521	-118.25351	PC FOR DELTA 1R CHANGES. SEE NOTED ON PLANS. CHANGE TO LIGHTING LAYOUT. MINOR POWER CHANGES. THIS IS SRILL CHECKING T24 ENERGY ONLY. NEW ENGINEER ON RECORD FOR THIS CHANGE. supp permit will be issued for increase in circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4868	17041-20002-14123	7767 N JAMIESON AVE	91335	12	189B129  1064	2120007013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Issued	06/02/2017 12:00:00 AM	ADDRESS	34.21184	-118.52157	changes to an approved set of plans.  changes include new solarworld 285 watts modules and additional strings.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.325 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4869	19041-10000-14747	1630 W SEPULVEDA BLVD	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/25/2024 12:00:00 AM		Issued	04/25/2024 12:00:00 AM	ADDRESS	33.81654	-118.30809	Core & Shell for an existing shopping center. New 1600Amp, 120/208V, 3Ph Serices for units: 100, 200, 300, 400 & 500. THERE ARE NO CONNECTED OAD AT THIS TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4870	19041-20000-22180	22135 W ROSCOE BLVD LOT #18	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 18.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4871	15041-20000-06199	5660 N KELVIN AVE	91367	3	174B109   313	2151020042	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Expired	03/28/2017 12:00:00 AM	ADDRESS	34.1738	-118.58683	Installation of new roof mounted solar PV array.  Single inverter system.  Total size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4872	13041-20001-34589	3512 N COPELAND PL	90032	14	142-5A237  92	5219022021	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	04/24/2014 12:00:00 AM	ADDRESS	34.08583	-118.16536	EXPEDITE FEES ONLY<<<New rooftop  PV system.  SYstem is UNGROUNDED.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4873	16041-10000-45232	10319 W ORTON AVE	90064	5	129B161   128	4315018010	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.05164	-118.41652	PV1 roof mounted solar system installation to a single family home. Microinverters rated at 360 watts each. (10) AC Modules-SPR-X22-360-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4874	10041-10000-01509	5851 W CLINTON ST	90004	4	141B185   645	5523005003	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Public Safety Only			01/28/2010 12:00:00 AM	01/28/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.08176	-118.32967	New fire alarm system for an existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4875	13041-20000-19849	2401 S VERMONT AVE	90007	8	123B197   510	5054026031	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.03441	-118.29176	new core and shell for new commercial/retail use. pc for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4876	19041-10000-22463	10243 N BOTHWELL ROAD	91324	12	204B117   215	2726009041	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.25667	-118.56182	Plan check for a PV1 5KW AC / 6.7KW DC roofmounted system with (1) inverter, (22) modules, and optimizer interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4877	10041-20000-19380	5700 N CANOGA AVE suite #130	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.17365	-118.59715	energy plan check suite # 130	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4878	18041-20000-08797	5333 N ZELZAH AVE	91316	5	171B129    17	2162008***	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.16819	-118.52222	REPLACING FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4879	15041-10000-35082	7835-7837 E MANCHESTER AVE	90293	6	096B153   458	4115025803		West Los Angeles				2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Expired	11/16/2017 12:00:00 AM	PIN	33.96006106	-118.43378901	PV1, ROOF MOUNTED SOLAR SYSTEM, TOTAL SIZE: 3KW-AC. (9) KYOCERA #KU2656ZPA(1) ABB# PV1-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4880	12041-10001-01368	2252 N TRACY TER	90027	4	148-5A205 160	5433017006	C1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2012 12:00:00 AM			PC Approved	05/03/2012 12:00:00 AM	ADDRESS	34.10205	-118.2735	Modification to previously approved set of drawings.  Combining two previously separate and permitted systems.       <<<<New 5.04kw rooftop photovoltaic system for an existing single family residence.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4881	14041-10000-32904	3150 W SAN FERNANDO ROAD Suite 6	90065	13	153B209   408	5458002013	[Q]C2-1VL-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Expired	12/20/2016 12:00:00 AM	ADDRESS	34.11582	-118.24713	Plan check for Title 24 only. Project site is a commercial space (not first time tenant; space will stay commercial). Total lighting area = 1,921 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4882	18041-10000-40556	13641 W RAYEN ST	91331	6	198B157   642	2625025010	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.23786	-118.43043	NEW 8.25KW ROOF MOUNTED PV SYSTEM WITH 23 PV PANELS ON A SINGLE FAMILY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4883	17041-20000-40098	11938 W PICO BLVD	90064	11	123B149  1015	4259039012	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.02973	-118.4491	service upgrade to an existing commercial building 600 amps.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4884	16041-10000-07665	5900-5908 N FIGUEROA ST	90042	1	151-5A229 148	5492015010	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.11043	-118.19071	PC FOR POWER ONLY. SERVICE UPGRADE TO 1600 AMP TO (E) MULTI UNIT BUILDINGS. SWITCHGEAR TO FEED ALL TENANTS IN BOTH BUILDINGS (MULTIPLE FEEDERS TO A BUILDING). NO NEW LOAD TO BE ADDED, WIRING TO PANELS TO BE SPLICED AND EXTENDED.9/8/16: MODIFICATION IS FILED TO COMPLY WITH ARTICLE 225.30 (B)(1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4885	12041-10001-04099	333 S LOS ANGELES ST	90013	14	129A213   149	5148001006	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Public Safety Only			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.04788	-118.24566	Revision to approved Delta 3 revision. Relocate FACP and change devices on circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4886	14041-10000-15284	1055 W 7TH ST	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.0507	-118.26334	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. SUITE 2800. HIGHRISE. 4285 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4887	13041-10000-12512	6255 W SUNSET BLVD #1410	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING. INTERIOR REMODEL OF OFFICE SPACE ON 14TH FLOOR (#1410). PERMIT FOR NEW LIGHTING, EXIT SIGNS, AND RECEPTACLES ON EXISTING CIRCUITS. NEW EQUIPMENT INSTALLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4888	17041-20000-35357	11647 N BALBOA BLVD	91344	12	213B133   276	2607013008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.28239	-118.50232	PV1. Install roof mounted PV system sized 17.2kW interconnected with MSP.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4889	16041-10000-20332	682 W 9TH ST	90731	15	015B197   799	7454005021	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	33.73624	-118.29185	PLAN CHECK FOR TITLE 24 ONLY.  TOTAL AREA = 722 SQ. FT.NEW SINGLE STORY FREESTANDING BUILDING WITH DRIVE-THRU, OUTDOOR SEATING. 400 A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4890	10041-20001-20616	1880 CENTURY PARK EAS #950	90067	5	135B161    42	4319001001	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	PIN	34.06321806	-118.4136341	PLAN CHECK T24 ENERGY (GERNAL/EMERGENCY) LIGHTING AND PERMIT FOR LIGHTING WORK ON EXISTING CIRCUITS. SUITE #950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4891	17041-30000-16666	4310 W JEFFERSON BLVD	90016	10	120B181   772	5046008004	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.02541	-118.34329	Plan check for Core and shell building 600 A Service upgade B# 16014-30000-05628	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4892	15041-10000-33390	266 S HARVARD BLVD #400	90004	10	135B193   181	5517019030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.06926	-118.30396	FULL PC FOR A TI TO AN OPHTHALMOLOGIST CLINIC. EXISITNG PANELS ONLY ADDING NEW CIRCUITS. PC FOR POWER AND ENERGY. TOTAL SQ. FT. 1835.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4893	12041-10000-18923	19950 W RINALDI ST	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.27535	-118.56939	First time tenant in a 3 story building.  Plan check power and energy 17,287 sq. ft T.I. for an UCLA Outpatient Medical Office Building with new optional standby generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4894	13041-10002-30050	7907 N CASABA AVE	91306	3	189B113   733	2107024064	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.21412	-118.57691	Expedited RSES plan check per applicant request.((((PV1, Install 5.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US. 21 modules Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4895	13041-20001-35557	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.24138	-118.60168	((3/18/2014- Changes made to approved set of plans. Added circuit to lunch room and removed switching from EM lighting.))T24 FOR EXISTING MANUFACTURING. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT. 27,000 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4896	10041-10000-22850	8936 S SEPULVEDA BLVD	90045	11	096B165  1080	4123001027	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	08/31/2011 12:00:00 AM	ADDRESS	33.95499	-118.39596	TI IN AN EXISTING OFFICE AREA.  PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4897	15041-10000-31884	9025 W BURROUGHS ROAD	90046	4	153B169   382	5564024025	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.11512	-118.39192	pv1, install new 12.099 kw dc roof-mounted solar array on a single family house.(37) modules: SUNPOWER SPR-327-NE-HHT-D(2) inverters: POWER-ONE PVI-5000 & 6000-OUTD-US-A-	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4898	13041-10000-23539	1810 S PANDORA AVE	90025	5	132B157   764	4317001005	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			08/28/2013 12:00:00 AM			PC Info Complete	01/15/2014 12:00:00 AM	ADDRESS	34.05644	-118.42429	PLAN CHECK FOR POWER AND ENERGY. NEW 9-UNIT 4-STORY APARTMENT BUILDING OVER PARKING GARAGE. 600 AMP SERVICE. methane zone. fire alarm variance filed on 1/15/2014.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4899	15041-20001-26127	15000 W CORONA DEL MAR	90272	11	123B129   711	4411030007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.03145	-118.52276	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (59) modules, (59) power optimizers, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4900	18041-10000-35209	649 N MADISON AVE	90004	13	141B197   561	5539023002	(Q)C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM			PC Approved	09/14/2018 12:00:00 AM	ADDRESS	34.08321	-118.28934	Energy plan check for a single story office T.I. Scope includes new service, equipment and lighting with a total area of 5,049-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4901	14041-20000-11180	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.08363	-118.32191	Lot transformer replacement B175 film vault #4New 300kVA transformerNew 1200A Bus switchboardTRANSFORMER REPLACEMENT LIKE FOR LIKE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4902	12041-10001-22364	738 N WILCOX AVE 1 - 10	90038	4	141B185   511	5533034013	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.08463	-118.33083	"((((((((((((((((((((((((((((((   changes made to previously approved set  600 amps multi meter is routed by conduit from wire way.   m.zandi 11/20/2014   )))))))))))))))))))))))))))))    NEW ""L"" SHAPE 3 & 4 STORIES 103 UNITS APARTMENT BUILDING. FIRE ALARM VARIANCE HAS BEEN FILED."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4903	19041-10000-22202	333 S GRAND AVE 17th Floor-Corridor	90731	15	018B197  1671	7451019029	R2-1XL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Issued	06/26/2019 12:00:00 AM	ADDRESS	33.74081	-118.29031	pc (energy only) for 17th floor - suite 1711 corridor lighting. area of scope is 2,300sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4904	17041-10000-37217	4201 W WILSHIRE BLVD #410	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.06189	-118.31911	ALTERATIONS IN EXISTING OFFICE SPACEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4905	19041-10000-02184	1631 S ALAMEDA ST	90021	14	120A215   201	5167018031	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.02204	-118.23969	pc for installation of new panel and a new circuit for despinser and DEF installation tank(diesel exhust fluid) in class 1 div 1 area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4906	12041-20000-24486	1100 N BANNING BLVD 1-90	90744	15	033B209   587	7423020046	RD6-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Apartment			10/12/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	ADDRESS	33.78533	-118.25813	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4907	18041-10000-23042	1051 N SWARTHMORE AVE #1-104	90272	11	129B125   836	4423016021	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.04828	-118.52508	"PLAN CHECK FOR POWER AND ENERGY FOR - First time tenant improvement to existing retail space #1-104 ""Paige Jean"" within Palisades Village Shoping Center. TOTAL AFFECTRED AREEA = 1261 SF."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4908	17041-10002-36876			10	114B185   659	5024023025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	PIN	34.00764609	-118.3301991	PC for new 5.8kWh battery(Powerwall).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4909	12041-10000-05140	1025 W 34TH ST 2ND FL	90089	9	120A201    84	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			PC Approved	03/06/2012 12:00:00 AM	PIN	34.02144011	-118.28222717	alterations on 2nd fl of king olympic hall of championsPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4910	15041-20001-02800	12473 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.97916	-118.41034	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4911	17041-10000-24177	16307 W STARE ST	91343	12	204B137   816	2678006019	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.25305	-118.48747	$0 permit fee due to senate bill 1222 from 2012PC FOR PV SYSTEM USING CENTRAL INVERTER RATED 11.4KW AC USING POWER OPTIMIZERS.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4912	16041-20000-36945	11162 W EXPOSITION BLVD 1-3	90064	5	123B153   252	4256016035	RD1.5-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Apartment			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.03518	-118.43353	New 14-device fire alarm system with FACP and annunciator for new 3-story 3-unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4913	16041-10001-33579	11915 W STAGG ST	91605	6	189B165   838	2310019022	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	11/14/2016 12:00:00 AM	ADDRESS	34.21221	-118.39282	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE 6.0KWac.(19)MODULES-LG 320N1C-G4(19)OPTIMIZERS-P300(1)INVERTER-SOLAREDGE 6000A-USNOTE: PERMIT IS PAID UNDER PCIS#16041-90000-33579	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4914	14041-10000-22196	374 S LA CIENEGA BLVD	90048	5	138B173  1016	5511033016	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.07175	-118.37623	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4915	10041-10000-22097	310 W WASHINGTON BLVD BLDG #2	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 7 UNIT TOWN HOME.   (BUILDING #2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4916	19041-10000-48997	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	THIS PROJECT IS TO MODIFY EXISTING BATHROOM WITH NEW POWER AND LIGHTING TITLE 24 PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4917	18041-10000-42864	1099 S SOUTH SEASIDE AVE	90731	15	015B205   31	7440032904	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM			Corrections Issued	11/29/2018 12:00:00 AM	ADDRESS	33.73275	-118.26873	FULL PC FOR NEW ELECTRICAL SERVICE SUBSTATION, (3) NEW 1200 MAIN SWITCHBOARDS, AND (3) NEW 7.5 MVA(AN) / 9.0 MVA(AF) TRANSFORMERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4918	14041-20001-17990	13053 W DICKENS ST	91604	2	165B161  1038	2385025031	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.14469	-118.41762	Expedited plan check per applicant.  PV1.  Install 7.2 kW roof-mounted, utility-interactive PV system.  (2) central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4919	17041-20000-35228	13920 W OTSEGO ST	91423	4	171B153   683	2269011004	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.16259	-118.43646	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4920	13041-20000-21950	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.2312	-118.36756	DEMO INTERIOR OF FORMER RALPHS MARKET. CREATE 7 NEW LEASE SPACES, 3 OF THEM SHELL ONLY AND THE REST TI IMPROVEMENTS. REMODEL EXTERIOR CANOPY AND PARKING LOT. NEW 120/208 2500A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4921	14041-20001-14990	17436 W LAHEY ST PV1	91344	12	210B129   272	2711011026	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.27314	-118.51442	INCREASE SYSTEM SIZE TO 5KW INVERTER WITH 22 MODULES TOTAL. TRANSFORMERLESS INVERTER. USING STANDARD PLAN. PERMIT ISSUED FOR INCREASED NUMBER OF MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4922	18041-10000-18623	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.06259	-118.35341	Power plan check for equipment demolation and refeeding power from an existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4923	12041-20000-20756	6930 W PARSONS TR	91042	2	207B201   139	2553013007	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.20	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	ADDRESS	34.26327	-118.28237	Plan check for PV. Single family dwelling. Ground mounted system. 13.734kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4924	16041-10000-44849	239 W 58TH ST	90037	9	108B201  1218	5101025027	R2-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	01/14/2017 12:00:00 AM	ADDRESS	33.98984	-118.27746	PC FOR PV  ROOF MOUNTED SYSTEM WITH 10 MODULES AND 3.6KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4925	17041-10000-35938	888 W 6TH ST 6TH FLR	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.05062	-118.25846	PC FOR OFFICE TI ON THE 6TH FLOOR IN A HIGH RISE BUILDING FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND CIRCUITS. TOTAL AFFFECTED AREA 4960 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4926	13041-20000-05158	6600 N TOPANGA CANYON BLVD #98	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Change to lighting and load in an existing retail space.  Load is 360 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4927	15041-20000-43221	8139 N TYRONE AVE	91402	6	192B153  1147	2212011010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.21906	-118.44403	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (23)MODULES-KYOCERA #KU2656ZPA(1)INVERTER- ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4928	17041-10000-45934	9356 N SAN FERNANDO ROAD	91352	6	198B169   101	2538002022	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	03/03/2021 12:00:00 AM	ADDRESS	34.23908	-118.39263	Service upgrade to 800A, 120/240V, 3ph, 4Wire with (2) 400A metersection and panels. Only receptacle load is provided in this scope of work.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
4929	17041-10000-07288	4551 S GLENCOE AVE	90292	11	105B153   615	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC FOR T24 ONLY. TOTAL AREA IS 1278 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4930	12041-20000-23188	12201 W MONTAGUE ST	91331	7	204B165    97	2537002008	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.25685	-118.39885	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4931	19041-30000-19181	8231 W 3RD ST Unit 4	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.07272	-118.36914	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,660 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4932	15041-20000-16297	936 S OLIVE ST UNIT 250	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #10 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4933	12041-20000-10485	6868 W GRENOBLE ST	91042	7	207B201   215	2553011020	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2012 12:00:00 AM			Plans on Hold	05/17/2012 12:00:00 AM	ADDRESS	34.26146	-118.28103	Ground mount PV system for a single family dwelling. 6.58kW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4934	17041-20001-05563	7236 N EASTHAVEN LANE	91307	12	186B089   712	2027022026	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.20264	-118.64782	Expedite fee.  PV1.  Install 11.76 kW roof mounted grid tied PV system.  (42) modules with 3.8 kW and 5.2 kW rated string inverters.  Derate of main service disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4935	12041-20000-09906	5701 S CENTRAL AVE	90011	9	108B209  1276	5103015049	M1-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	33.99059	-118.25665	T.I. to existing space for Subway.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-09909	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4936	11041-10000-00636	2600 W WILSHIRE BLVD	90057	1	133-5A201 122	5141008900	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.06041	-118.28167	new five story commercial bldg , 560 devices and one panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4937	19041-10001-34788	1550 S BROCKTON AVE	90025	11	126B145   708	4263034024	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Apartment			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	05/14/2021 12:00:00 AM	ADDRESS	34.04022	-118.46005	NEW FIRE ALARM SYSTEM, PARTIAL PERMIT WAS ISSUED UNDER 19041-10000-34788.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4938	12041-10000-12019	11240-11250 W SHERMAN WAY	91605	2	183B173   143	2319001009	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM	09/06/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	PIN	34.19903644	-118.3765673	PLAN CHECK T24 ENERGY FOR OFFICE ENCLOSURE IN AN EXISTING WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4939	14041-20000-25951	960 E 12TH ST 1-6	90021	14	123A211   213	5132013029	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.03119	-118.24802	PC FOR POWER ONLY. NEW SERVICE UPGRADE TO 600 3P4W 120/240. NEW LOAD CHANGES. PC FOR SERVICE AND TENANT PANEL BOARD REPLACEMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4940	16041-30000-04562	12209 W WILSHIRE BLVD	90049	11	126B145   232	4264026006	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	PIN	34.04347531	-118.46880107	Title 24 plan check only.  Total area = 1,325 sq. ft.Change of use from office to nail salon and interior TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4941	13041-10002-35730	888 S HOPE ST	90017	14	129A209   239	5144020020	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	34.0452	-118.25996	((((10/31/2014 Changes to the approved set of plans. Changes reflected on electrical floor plan. Lighting in parking structure has been reduced to meet Title 24 allowances. Area = 206,198 sq. ft. ))))((((7/10/2014  Changes made to approved set.  Changes made to fire pump and lighting locations in stairwell))) plan was aporoved as a counter job with application was taken in as a regular plan. permit is existing as a plan check only.PLAN CHECK FOR POWER AND ENERGY FOR NEW PARKING STRUCTURE. SUBMITTAL FOR PARKING AND RETAIL. BUILDING # 13010-10001-01140	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4942	14041-20000-06106	5536 N RESEDA BLVD	91356	3	174B125   494	2160010028	P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.1708	-118.5358	T24 FOR EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4943	17041-20001-46465	18637 W NAU AVE	91326	12	213B121   367	2871011040	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC in Progress	01/06/2018 12:00:00 AM	ADDRESS	34.28089	-118.53975	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.10.4kW ungrounded system. (1) 6.6kW inverter. (1) 3.8kW inverter.(40) 300W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4944	12041-10000-21024	5062 E WILLIAMS PL	90032	14	136-5A235 229	5223007006	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.06819	-118.17441	Plan check roof mounted 3.3KW photovoltaic system using SunPower transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4945	18041-20000-11664	18000 W DEVONSHIRE ST	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.25698	-118.52508	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,287 sq. ft.Note: Building application has been generated under 18016-20000-00079	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4946	13041-20000-35998	20623 W BLACKHAWK ST	91311	12	204B109    93	2707011036	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.25832	-118.58273	pc for pv1 single family dwelling. total system size 5 kw ac using transformerless inverter nonstandard plna, using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4947	15041-20001-30427	11512 W CLARKSON ROAD	90064	11	120B153   660	4258015026	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.02501	-118.4357	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family home.  Total system size = 3.8 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4948	11041-10000-22773	1255 N HIGHLAND AVE	90038	4	144B185   180	5532006001	C2-1D-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.09414	-118.33888	TENANT IMPROVEMENT TO EXISTING STORE INTERIOR ( NON-STRUCTURAL)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4949	17041-20002-20357	7702 N BALBOA BLVD	91406	6	189B133   905	2205008029	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Issued	12/08/2017 12:00:00 AM	ADDRESS	34.21031	-118.50093	12/08/2017 Changes to an approved set of plans. Changes include the addition of a new house panel and meter.*****Previous Work Description*****Plan check for power only. Replacing damaged 800A service panel and utility service due to LADWP transformer failure. Reconnecting existing unit panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4950	17041-20000-18639	14647 W MORRISON ST	91403	4	169-5A149  36	2263027001	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Expired	03/24/2024 12:00:00 AM	ADDRESS	34.16043	-118.45252	installation of new powerwall 5kw (battery back up) to an existing pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4951	16041-20004-18232	8500 N BALBOA BLVD	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	Changes to an approved set of plans. Relocation of equipment noted under delta 4.No new loads were added to plan. Eqipment being relocated have been addressed under application 16041-20003-18232	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4952	19041-10001-27374	431 E 89TH ST	90003	9	096A207   155	6041023901	OS-1XL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			PC Approved	03/04/2021 12:00:00 AM	ADDRESS	33.9557	-118.26719	void....... for fee estimate onlyPlan check for (2) PV2 roofmounted system located in the same building. Scope includes a total of (286) modules and microinverters, (22) ckts, (2) load centers, (9) 1600-Amp sections. Interconnecting through an existing 400-Amp service and a new 1600-Amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4953	16041-20001-39497	13146 W KUEN PL	91401	4	171B157   128	2345021018	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	PIN	34.16789002	-118.41991756	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with a 400A MSP.10kW ungrounded system. (28) 340W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4954	11041-10000-05599	888 S FIGUEROA ST	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM			PC Approved	03/25/2011 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI FOR A 21-STORY BUILDING.  RELOCATION OF LIGHTS ONLY, T-24 OVER THE COUNTER PLAN CHECK WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4955	18041-20000-33846	20603 W CHESTNUT CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.29244	-118.58387	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4956	16041-10004-16440	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	"(11/09/17) Restamp for a lost of plan (change to approved set under delta-27, #16041-20003-16440) .(3/30/17)changes to an approved set of plans.  changes include the addition of exit signs to all floors except floor 3and 4.  changes noted delta 27. this is plan check only.(2/16/2017)changes to an approved set of plans.  Changes noted ""note 23"" Change from fully rated to series rating to reflect existing conditions.  See attached short circuit load study.  This is plan check only.(12/16/2016)CHANGES TO AN APPROVED SET OF PLANS TO REFLCT FIELD CONDITIONS, CHANGES NOTED UNDER DELTA 20.THIS IS PLAN CHECK ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4957	17041-20001-36363	5461 W JEFFERSON BLVD	90016	10	120B177   474	5048017040	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.02617	-118.36558	expeditePV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 60KW INTERCONNECTED WITH MSP.(253) mitsubishi modules(1) yaskawa 60kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4958	19041-20000-36570	4383 N SEPULVEDA BLVD #1- #16	91403	4	166-5A145 154	2276042001	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	08/05/2020 12:00:00 AM		Permit Finaled	03/13/2023 12:00:00 AM	ADDRESS	34.14981	-118.46782	Power and lighting for new 800A 240/120V 3ph-4w service. Scope of work includes panels, equipments and lights.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4959	13041-20001-27842	7350 W MELROSE AVE	90036	5	141B181   614	5526020001	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	PIN	34.08330039	-118.3499936	LIGHTS, SWITCHES AND OUTLETS FOR BATHROOM AND WALK IN COOLER (((plan check only for T24 energy. No permit under this application, permit already issued under original.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4960	15041-10000-22658	5905 W WILSHIRE BLVD	90036	4	135B177   424	5508016901	PF-1D	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.06282	-118.35793	Energy plan check for an equipment (pump) room located in the museum. Scope include new lighting and receptacles. Total area is 381-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4961	19041-10000-25107	10943 N HERRICK AVE	91331	7	210B161   718	2534024905	OS-1XL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.26922	-118.41302	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4962	18041-10000-26777	653 E MILWOOD AVE	90291	11	108B145   951	4241005024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	33.99215	-118.46385	PLAN CHECK FOR ROOF MOUNTED 3.0KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(PVI-3.0-OUTD-S-US-Z-A) WITH 10 PANELS(TRINAMOUNT TSM-300DD05A)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4963	14041-20001-03102	1631 W 259TH PL	90710	15	033B193   216	7411003028	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	33.78761	-118.30548	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE5.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4964	19041-10000-19102	12610 W RAYMER ST	91605	2	186B161   571	2324003021	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.2033	-118.4078	INSTALL (35) NEW FIRE ALARM DEVICE AND (1) NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4965	16041-10000-44965	3671 S WESTERN AVE	90018	8	120B193  1515	5041023024	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.02138	-118.30918	PLAN CHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION 33-UNIT, 4-STORY, TYPE VA APARTMENT BUILDING OVER FIRST FLOOR PARKING GARAGE IN TYPE IA. SERVICE SIZE = 1600A, TOTAL SQ FT. 29376	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4966	14041-10000-23616	1100 S SAN PEDRO ST #G09	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.03515	-118.25194	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 627 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4967	18041-10000-32283	15220 W VANOWEN ST	91405	6	180B145    44	2235004008	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.19371	-118.4644	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4968	15041-20002-36497	20953 W HEMMINGWAY ST	91304	3	189B109   513	2109013018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM			PC Approved	12/01/2015 12:00:00 AM	ADDRESS	34.2145	-118.59038	12/01/15Re-plan check for lost/missing plans. permit paid under pcis#15041-20000-36497/E15VN03073 ((((Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (25) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4969	17041-10000-40325	21601 W VICTORY BLVD	91303	3	180B105    75	2139001009	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.18827	-118.59992	PC for T24 only for retail TI for new lighting. Installing new lights and receptacles in existing panels. Total area is 3406sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4970	12041-10001-01744	15485 W BRIARWOOD DR	91403	4	163-5A145  94	2281019002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2012 12:00:00 AM			PC Approved	01/30/2012 12:00:00 AM	ADDRESS	34.14215	-118.47061	Plan check to correct the grounding of the service and eliminate the GEC from the neutral of the subpanel, and correct the isolated neutral.  The equipment grounding conductor from the service disconnect to the subpanel is the EMT conduit, no equipment grounding conductor is run from the service to the subpanel.  The PV combined GEC/EGC is 8 AWG copper, and is run all the way from the inverter to the service grounding bus.  See existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4971	13041-20000-16037	1909 N WESTRIDGE TER	90049	11	135B133    16	4492012014	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.07012	-118.50003	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM 6.12 KWDC. 24 PANELS AND 1 SUBPANEL AND MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4972	19041-20000-52626	18827 W ROSCOE BLVD BLDG 3	91324	12	192B121   738	2785019013	RA-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	07/30/2020 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	34.22078	-118.54326	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4973	14041-20000-05367	14955 W DICKENS ST 1-18	91403	4	166-5A147  52	2276004011	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			02/26/2014 12:00:00 AM			Reviewed by Supervisor	03/12/2014 12:00:00 AM	ADDRESS	34.15153	-118.45925	PV2 NEGATIVELY GROUNDED SYSTEM FOR APARTMENT BUILDING. TOTAL SYSTEM SIZE 12KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4974	11041-20000-11807	2200 W 3RD ST SUITE 120	90057	1	135A203   309	5154034006	C2-1	Central	Westlake			2088.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.0632	-118.27405	PLAN CHECK POWER AND ENERGY FOR T.I. MEDICAL OFFICE SUITE ON THE 1ST FLOOR. OSHPD-3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4975	17041-10000-33814	7535 S BROADWAY	90003	9	099B201    56	6031010020	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	33.971	-118.27849	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4976	18041-10000-11243	17278 W DEVONSHIRE ST	91325	12	204B133   194	2694015007	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.2574	-118.51066	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING MICRO-INVERTERS. (15) MODULES AND (15) MICRO-INVERTERS. TOTAL SYSTEM SIZE IS 3.45KWAC/4.275KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4977	14041-10000-02494	15317 W VANOWEN ST UNIT B	91406	6	183B145   747	2234024037	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.1941	-118.46692	PLANCHECK FOR T24 ENERGY UNDER INSPECTORS REQUEST. TENANT IMPROVEMENT for a  7-ELEVEN CONVENIENCE  retail  store. 1856 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4978	16041-20000-44947	6635 N FALLBROOK AVE	91307	12	180B097   170	2038040005	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Issued	04/12/2017 12:00:00 AM	ADDRESS	34.18998	-118.6262	Plan check for energy only. TI to retail (Target). New lighting (incl. receptacles). 86,461sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4979	13041-20004-35622	11975 W BLUFF CREEK DR BLDG#5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	33.98224	-118.40247	PC FOR CHANGES TO APPROVED SET OF PLANS. CHECKING CHANGES TO FAULT VALUES AND AIC RATING OF EQUIPMENT DUE TO NEW VALUES FROM CHANGES TO CONDUCTORS. ALSO CHANGE TO SITE LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4980	10041-20000-25266	11845 W OLYMPIC BLVD #1245	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	PIN	34.03325831	-118.45191172	Plan check T24 Energy (general/emergency) lighting for office TI #1245	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4981	16041-30000-20319	2256 S BARRY AVE	90064	11	123B153   413	4260014035	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.03353	-118.44564	NEW ADDITION OF OFICE/PARKING GARAGE TO AN EXISTING COMMERCIAL BUILDING. CONNECTING TO EXISTING 1200 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.BUILDING APPLICATION UNDER 15041-10000-05286	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4982	19041-20001-43805	10265 N HADDON AVE	91331	7	204B157   511	2646023038	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.25673	-118.42437	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, CHANGES MADE TO ROOF LAYOUT PAGE, ELEVATION PAGE,  AND SITE PLAN PLACARD PAGE. RELOCATION OF EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4983	10041-10000-14422	6201 W HOLLYWOOD BLVD	90028	13	148-5A189  54	5546031001	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.1018	-118.32461	NEW MIXED USE (APARTMENT, RETAIL, OFFICE), 6 STORY BUILDING OVER 5 LEVELS OF BASEMENT GARAGE,  516 UNITS ( 11 TYPES ) OF APARTMENT AND 18 UNITS OF LIVE/ WORK.  Note: above description will be amended by Building section	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4984	11041-10000-26017	2274 W BRUNA PL	90027	4	153B193   165	5588002038	RE11-1	Central	Hollywood	Greater Griffith Park, Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2011 12:00:00 AM	01/17/2012 12:00:00 AM		Issued	01/17/2012 12:00:00 AM	ADDRESS	34.1144	-118.30364	Plan check 6.3 KW roof mounted photovoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4985	17041-10001-41041	1030 N ALVARADO ST 100	90026	13	139-5A207 119	5404003037	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1957.20	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.07715	-118.26352	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR YOGA PLACE. A3 OCCUPANT LOAD < 100. TOTAL AFFECTED AREA IS 3604 SQ. FT. B#17016-10000-25843NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-41041	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4986	16041-10001-29788	1103-1109 S BOYLE AVE	90023		123A219   118	5170008022							Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	34.03162	-118.2203	EXPEDITE PER APPLICANT REQUEST.((((PV2. NEW SOLAR SYSTEM ON AN EXISTING COMMERCIAL BUILDING'S ROOF-TOP. TOTAL SYSTEM SIZE IS 534.65KWdc / 400KWac. (1445)MODULES-SUNPRME MAXIMA-GXB-370(5)INVERTERS-DELTA ELECTRONICS M80U-122(1)800A SUBPANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4987	17041-20001-14632	8945 N NEVADA AVE	91304	12	195B101    50	2010021008	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM			PC Approved	05/09/2017 12:00:00 AM	ADDRESS	34.23329	-118.60775	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (37) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4988	17041-20000-40678	7901 S HULBERT AVE	90293	11	099B153   136	4114007001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	33.96356	-118.43322	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (26) modules, (26) micro-inverters, (3) load centers, and (1) battery back-up system.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4989	12041-20000-27622	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Issued	12/06/2012 12:00:00 AM	ADDRESS	33.9451	-118.37436	Change to lighting in the 2nd level of an existing hotel space to convert to office space.  Load is less than 400 amps.  Not a place of assembly.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit Fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4990	17041-20002-42975	308 S GLENROY AVE	90049	5	135B145    43	4366020007	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM			PC Approved	12/29/2017 12:00:00 AM	ADDRESS	34.07017	-118.46029	12/29/2017 Changes to an approved set of plans. Changes have been done to the configuration of the equipment layout and feeders. Per applicant, PV system efficiency power output is 15.7 kWac.*****Previous Work Description*****Note: $0.00 permit fee due to CA Senate Bill 1222pv1install roof mounted pv system sized 11kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4991	11041-10000-24384	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM			Reviewed by Supervisor	02/27/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	Plan check power and energy for new health club in existing building. Existing 5000A service.New distribution boards, xfrmr, equipment, and ckts supplying health club.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4992	15041-20000-08922	21215 W BURBANK BLVD 6th Floor	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	34.17353	-118.59268	Plan check for Title 24 only. Project scope is a tenant improvement to a corridor on the 6th floor of a high-rise building. Total lighting area = 1,997 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4993	12041-10000-27536	12141 N BELLANDO CT	91344	12	219B125    97	2601073022	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.29476	-118.52579	PV1 9.6KW ROOF-MOUNT FRONIUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4994	14041-20000-35788	4409 N AZALIA DR	91356	3	165B121   135	2177014010	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.15125	-118.54068	PV1. Install roof mounted PV system sized 6.45 kW. Interconnected with main service pannel. (30) Sunmodule Plus SW270 Modules(30) Enphase M215 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
4995	15041-10000-34743	758 S MAIN ST	90014	14	127-5A211 219	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.04275	-118.25284	Energy plan check for a change of use from retail to a restaurant.  Plan check is under 2008 Energy code due to building permit is submited before July 1, 2014. Plan Check is for change of engineer for application # 15041-10000-11799.  Building permit Reference # 12016-10000-18056. & # 15016-10000-02880.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
4996	18041-10000-31770	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	07/23/2020 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	PIN	33.92817449	-118.43220714	PC FOR EV CHARGERS IN INDUSTRIAL STURCTURE (CITY OF LA PROPERTY). SCOPE INCLUDES NEW PANELS FEEDING FROM 480V/277V DIST. TOTAL 30 EV CHARGERS (TYPE LEVEL 2).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
4997	14041-20000-16481	5014 N EAGLE VIEW CIR	90041	14	162A221   180	5682020015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.13801	-118.21872	2.5KW roof-mounted PV1 system with a 3.8kw Solar edge SE3800A-US inverter, (10) Renesola 250w solar modules, and Solaredge Power Optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4998	15041-20000-02117	10438 N ONEIDA AVE	91331	7	207B157  1113	2620014017	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.26059	-118.42659	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4KW.(16) HYUNDAI MODULES(16) ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
4999	13041-10000-12511	122 W 4TH ST 1ST	90013	14	129A211    63	5149023013	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.0485	-118.24808	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. T.I. OF EXISTING RESTAURANT (1,365 SF)- STOREFRONT & INT REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5000	19041-20000-16413	1479 S LA CIENEGA BLVD 1-20	90035	5	129B173   521	4303033014	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.05096	-118.37644	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR EXISTING 1-STORY MOTEL. SCOPE OF WORK INCLUDES 1 FACP, AND 37 FIRE ALARM DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5001	15041-10000-06137	4401 W SUNSET BLVD 1st fl	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	34.09708	-118.28526	small office space remodeled  to be housing video/audio productionsplan chk is for Title 24; E-permit on separate spplicatio	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5002	16041-10000-27773	22736 W VICTORY BLVD	91367	3	180B097   632	2039020021	C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.18624	-118.6225	Remove outdoor HID fixtures and replace  with new LED fixtures - plan check T/24 only. Total area 25150 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5003	14041-20000-06224	2421 N NALIN DR	90077	5	156B145   353	4378002021	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.11997	-118.46656	PV1 TRANSFORMERLESS SYSTEM .TOTAL SYSTEM SIZE 5.0KWAC WTIH SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5004	10041-10000-16874	1341 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05053	-118.22421	Solar voltaic system installed on the roof of the building.  Consists of 12 modules,  12 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5005	16041-20000-40690	6225 W CENTURY BLVD 13th Floor	90045	11	090B165     5	4124026005	C2-2, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	33.9457	-118.39456	Plan check for Title 24 only. Project site is an existing space within a commercial building. Project scope is a change of use from kitchen to fitness center/tenant improvement. Total lighting area = 1,660 sq. ft.Note: Building application has been generated under 16016-10000-25574	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5006	16041-10000-34089	3415 S SEPULVEDA BLVD	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.02055	-118.42347	Energy plan check for an office T.I . Scope includes new lighting and receptacles. Total area is 1393 sq feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5007	17041-10000-45491	2827 W BELLEVUE AVE	90026	13	139-5A203 173	5402006006	C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	Yes	1958.04	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.07691	-118.27546	PC for T24 only for beauty salon TI. Installing three new panels (BL. BP and B), new lights and receptacles. B# 17016-10000-26086. Total area 1120sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5008	16041-20000-12064	11411 N PORTER RANCH DR	91326	12	213B113   325	2701072004	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.27855	-118.57253	Plan check for a PV2 carport PV system. System size is 120 kWac and consists of (8) inverters, (480) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5009	12041-10001-13387	2133 N PARK DR PV1	90026	13	144B213   796	5415008042	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1972.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.0883	-118.2453	PLAN CHECK FOR INSTALLATION ROOF MOUNTED 7.5KW ENPHASE M215 MICROINVERTERS. PERMIT INCLUDES NEW LOAD CENTER AND ADDITIONAL 33 MICROINVERTERS. MODULES AND 1 INVERTER PERMIT ON THE PREVIOUS PERMIT #12041-10000-13387.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5010	14041-20000-32225	10510 N WYSTONE AVE	91326	12	207B121   691	2728016033	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.26167	-118.54813	PV1Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size: 6kW. Ungrounded system.18 327W pv modules across 3 strings (5+5+8).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5011	17041-20000-16931	10250 W CONSTELLATION BLVD Suite 3050	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,237 sq. ft.Note: Building application has been generated under 16016-10000-29123	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5012	14041-10000-30077	555 W 5TH ST 6th floor	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.05016	-118.25369	Renovation of elevator lobby and multi-tenant corridor on the 6th floor of a high-rise building. New lighting and power (convenience receptacles). Lighting area = 3,223 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5013	13041-10000-22160	1515 N SAN FERNANDO ROAD 1-87	90031	1	147A217   364	5442002908	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.09631	-118.23259	New fire alarm system for 3 story Rio Vista Apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5014	19041-30000-45910	2029 S CENTURY PARK EAST #1780	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	OFFICE T. I. TO INCLUDE NEW NON-LOAD BEARING PARTITIONS, CEILINGS & FINISHESAREA OF WORK - 2,373 S.F.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5015	13041-10001-35458	2450 N ARMSTRONG AVE	90039	4	148-5A207 106	5439015006	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/23/2014 12:00:00 AM	ADDRESS	34.10097	-118.26131	Expedited RSES plan check per applicant request.{{PV1, Install 3.5 kw DC roof-mounted solar array, interconnect with main service for a one story house. (1)Transformerless inverter(s): SOLAREDGE SE 3800A-US, (14)Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5016	16041-30000-45310	728 N LA BREA AVE	90038	5	141B181   533	5525008028	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.08433	-118.34386	Title 24 plan check.  Change of use to from retail/office to Yoga Studio & T.I.  Total area = 3,140 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5017	15041-10000-12220	13310 N RALSTON AVE	91342	7	225B141   157	2501002060	[Q]MR1-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.31402	-118.47422	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3112 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5018	19041-10000-06197	621 S VIRGIL AVE #300	90005	10	135B197  1126	5077008004	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2111.20	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.06276	-118.28722	REMOVE INDOOR FLUORESCENT TROFFERS WITH NEW RETROFIT KIT. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5019	18041-10000-46011	216 S LAKE ST	90057	13	135A205    63	5154008019	R3-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Issued	12/26/2018 12:00:00 AM	ADDRESS	34.0657	-118.27208	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 50 MODULES (SUNPOWER X-SERIES X22-360) AND 1 CENTRAL INVERTAR (SUNNY BOY 7.7-US 240V/7950W). SYSTEM SIZE IS 18KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5020	17041-10000-04627	20101 W RINALDI ST BLDG S2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.27545	-118.57197	PC FOR POWER AND ENERGY. NEW BUILDING S2  -1 STORY SHELL ONLY  COMMERCIAL BLDG - SERVICE SIZE 600 A 277/480 V. TOTAL AREA 2356 SQ FT. OUTDOOR ONLYBUILDING APPLICATION 16010-10000-06142	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5021	12041-20000-24224	4608 N WOLFE WAY	91364	3	168A109   153	2172013045	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.15366	-118.58881	PV solar installation in a single family dwelling. 6kVA inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5022	19041-20000-47190	6810 S LA TIJERA BLVD	90045	11	102B173   108	4103002025	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	09/16/2020 12:00:00 AM		Permit Finaled	12/28/2020 12:00:00 AM	ADDRESS	33.97696	-118.37188	PV3 PLAN CHECK FOR TI REMODEL, T24 LIGHTS AND OUTLETS, NEW PANEL. TOTAL SQUARE FOOTAGE = 1092 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5023	14041-10000-04955	7712 S TOLAND AVE	90045	11	099B173   332	4127015009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	33.96767	-118.37652	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON  A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5024	15041-10000-30381	350 S GRAND AVE	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Issued	01/19/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	REPLACEMENT OF FIRE ALARM SYSTEM IN A HIGH RISE BUILDING, 53 STORIES WITH ABOUT 25 FLOORS WITH EXISTING DEVICES AND WORK TO BE DONE IN THE CORRIDOR.  4054 FIRE ALARM DEVICES, 8 FIRE ALARM PANELS, 2 CONTROL PANELS AND 2 COMMUNICATION PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5025	14041-20000-01279	9601 N MASON AVE unit A	91311	12	201B109   284	2748003080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.24457	-118.57997	revise energy plans add two bathrooms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5026	16041-10000-20233	450 S WESTERN AVE # 207	90020	10	135B193   649	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (VERIZON STORE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR UNIT#207. TOTAL AFFECTED AREA IS 490 SQ. FT. B#16016-10000-10716	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5027	14041-20000-14174	20287 W VIA MEDICI	91326	12	219B113   151	2701043023	RE11-1-H, RS-1	North Valley	Chatsworth - Porter Ranch, Mission Hills - Panorama City - North Hills	North Hills West, Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Expired	08/01/2016 12:00:00 AM	ADDRESS	34.2946	-118.57589	PV1Install roof-mounted solar array, interconnect with main panel. System size: 7.8kW(1) Power-One Aurora PVI-3.6-OUTD-S-US-Z-A transformerless inverter(1) Power-One Aurora PVI-4.2-OUTD-S-US-Z-A transformerless inverter(36) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5028	16041-10000-29946	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Closed	08/22/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	FPC FOR T24 ENERGY ONLY. PROVIDING NEW LIGHTING TO BUS GATE FOR TERMINAL 2. DISTRIBUTION BOARD WILL BE UNDER SEPARATE PERMITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5029	15041-20000-43544	6310 N PAT AVE	91307	12	180B085   194	2032007006	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.18546	-118.65851	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(18)MODULES-SOLARWORLD SW 285 MONO BLK(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5030	16041-10000-21289	318 E GAGE AVE	90003	9	105B205   919	6006020012	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Expired	07/20/2018 12:00:00 AM	ADDRESS	33.9823	-118.26885	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(12)MODULES-GIGAWATT 250255PB(1)INVERTER-SUNNYBOY 3000TL-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5031	16041-20001-32451	15511 W HIGH KNOLL ROAD	91436	5	165B141   399	2285006023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM			PC Approved	09/23/2016 12:00:00 AM	ADDRESS	34.14652	-118.47266	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.1 kWac and consists of (30) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5032	16041-10000-42197	1334 S HAUSER BLVD	90019	10	129B177   660	5085032020	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.05022	-118.35601	PV2 roof mounted solar system instalation to commercial property. Installing 3.0 KW central inverter being fed by 15 solar modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5033	14041-10000-34521	11224-11244 W MORRISON ST 1 - 8	91601	2	168B173    48	2353016046	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.16065	-118.37532	4 story 8 unit apartment building,   fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5034	10041-10000-08310	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022	A1-1-H, A2-1, PF-1XL, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM			PC Approved	06/29/2010 12:00:00 AM	ADDRESS	34.08694	-118.47588	Replace emergency generator from a 175Kw to 500Kw at the existing building (Getty Center).  Install new switchboard, panel, and two ATS.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5035	19041-20000-09561	11806 N MARIPOSA BAY LANE	91326	12	216B113   174	2701035053	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.28538	-118.5661	INSTALLATION OF (4) 5KW TESLA POWERWALL TO A EXISTING SFD WITH A EXISTING PV SYSTEM.  SCOPE OF WORK ALSO INCLUDES 200A SUBPANEL AND 400A MSP UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5036	16041-20000-25568	7722 N FAUST AVE	91304	12	189B097  1093	2013031021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.21069	-118.62032	"""$0 permit fees due to senate bill 1222 ""PV1. ROOFMOUNTED SOLAR SYSTEM.  A NEW PV SYSTEM WITH BATTERY BACKUP.  SUNVERGE SIS 6848 . SYSTEM SIZE: 8.8KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5037	17041-20000-36690	11801 W MISSISSIPPI AVE 1-2 flr	90025	11	123B149   359	4262033020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.03444	-118.45125	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5038	19041-20000-20180	537 S BROADWAY SUITE #200-SUITE#210	90013	14	129A211   120	5149033003	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.04731	-118.25166	T24 plan check for lights only in suites 200 and 210 for existing high rise office. Total square footage = 6938sfTitle 24 Required for Power ReleaseB#19016-30000-06268	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5039	12041-20000-10818	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM			PC Approved	05/10/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for energy and emergency lighting. 20th floor. Commercial High-rise. Office. 21900 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5040	13041-10000-08644	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.07594	-118.35916	new 600 A service with 2 distro boards/transformers and 200a receptacles . methane zone.  pc for power for movie star trailer at cbs studio.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5041	19041-10000-02298	13115 N TELFAIR AVE	91342	7	222B141   327	2604002050	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.30778	-118.47865	PLAN CHECK FOR ROOF MOUNTED 166.5KVA PV2 SYSTEM CONSISTING OF 3 CENTRAL INVERTERS (5)SE33K-US WITH 500 MODULES USING P860 OPTIMIZERSPermit fee is $ 0 in accordance with AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5042	12041-10000-09673	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Info Complete	06/12/2012 12:00:00 AM	ADDRESS	33.77884	-118.29327	Plan check for installation of 400HP air compressor. Installation not in hazardous area. (2400V system)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5043	13041-10000-25808	4543 N SUNNYSLOPE AVE	91423	4	168B157   883	2360015027	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.15338	-118.427	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 6.5 KW DC IN A 2-STORY HOUSE ON NON-STANDARD PLAN. LOAD CENTER IS USED. UNGROUNDED SYSTEM.(26)MODULES: TRINA SOLAR #TSM-250PA05.18(2)INVERTERS: SOLAREDGE #SE3000A-US, SOLAREDGE #SE3800A-US,	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5044	10041-20000-12702	10138 N CANOGA AVE	91311	12	204B105   538	2747009017	(Q)CM-1, (Q)P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.25475	-118.59713	Plan check for 9.38 KW PV System commercial	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5045	14041-10001-05695	620 N AVENUE 64	90042	14	154-5A233  32	5493022008	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.11941	-118.17842	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 1.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(6) MODULES: CANADIAN SOLAR CS6P-250PX(1)TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5046	17041-30000-46216	6400 N LANKERSHIM BLVD	91606	2	180B169  1100	2335010001	C1-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.03	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.18703	-118.38756	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,664 sq. ft.Note: Building application has been generated under 17016-20000-35137	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5047	19041-10000-04941	222 S HILL ST	90012	14	130-5A211  27	5149009023	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.05244	-118.24815	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 PANEL AND 263 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5048	17041-10000-42127	22035 W VENTURA BLVD	91364	3	171B101    68	2169025065	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Issued	11/21/2017 12:00:00 AM	ADDRESS	34.16874	-118.60713	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5049	16041-20000-01551	12457 N GLADSTONE AVE	91342	7	219B161   235	2525018059	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM			PC Approved	01/15/2016 12:00:00 AM	ADDRESS	34.29638	-118.41277	TI to existing commercial building (industrial). Plan check for energy only. Adding new lighting. Total sqft. 414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5050	11041-10000-05616	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM			PC Approved	03/22/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	T-24 FOR OUTDOOR LIGHTING ONLY.  OVER THE COUNTER PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5051	18041-20000-03986	1021 N MCCADDEN PL	90038	4	144B185   884	5532027003	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			PC Info Complete	02/02/2018 12:00:00 AM	ADDRESS	34.08961	-118.33756	TI IN AN EXISTING COMMERCIAL AREA. EPC for T-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5052	13041-10000-36310	217 N AVENUE 49	90042	1	150A225   204	5467029025	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1851.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/28/2014 12:00:00 AM	ADDRESS	34.10513	-118.20443	PV1, Install 4 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (16) Modules: Trina Solar TSM-250PA05.18.(16) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5053	15041-10000-16609	1840 S CENTURY PARK EAST 3RD FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHING ONLY.  TOTAL SQUARE FOOTAGE 608.  SCOPE OF WORK IN THE 3RD FLOOR COORIDOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5054	15041-10000-12021	200 WORLD WAY TERM 2-# 233	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	AT LAX, INSTALLATION OF ILLUMINATED SIGNS FOR TENANATPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5055	09041-20001-11196	10380 W WILSHIRE BLVD PENTHOUSE-#2102	90024	5	135B157   141	4327013***	[Q]R5-3	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			04/20/2011 12:00:00 AM			PC Approved	04/20/2011 12:00:00 AM	ADDRESS	34.06719	-118.4277	CHANGE FEEDER SISE TO MDAB FROM 600 KCM T0 500 KCM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5056	16041-20000-20408	14933 W CALVERT ST	91411	6	178-5A149 315	2242024050	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.18132	-118.4586	PLANCHECK FOR POWER AND ENERGY FOR A COMMERCIAL CORE/SHELL  BUILDING ONLY WITH FIRE DAMAGE. NEW SERVICE 3000 AMPS 277/480V 3-PHASE 4-WIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5057	18041-20000-35609	6200 N CANOGA AVE Ste 350	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.1833	-118.59719	Tenant improvement of (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5058	16041-20001-20822	13535 W VAN NUYS BLVD	91331	7	207B157   848	2619026027	[Q]C2-1VL-O-CDO-CUGU, [Q]P-1-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM			PC Approved	12/27/2017 12:00:00 AM	ADDRESS	34.26187	-118.42829	[[12/26/17 CHANGES TO APPROVED SET. PLANCHECK ONLY.  DELTA 2 CHANGES ARE CLOUDED ]]]NEW CHURCH.  FULL PLAN CHECK FOR PLACE OF ASSEMBLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5059	14041-20001-08284	14326 W CHANDLER BLVD UNIT 2	91401	4	171B153   130	2248016***	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	Apartment			03/27/2014 12:00:00 AM			PC Approved	05/02/2014 12:00:00 AM	ADDRESS	34.16822	-118.44508	((((EXPEDITE FEES)))PV2. CONDOS. PV SYSTEM 12 MODULES USING MICROINVERTER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5060	15041-10001-02468	1712 W SUNSET BLVD	90026	13	139-5A209 143	5404017020	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM			PC Approved	07/15/2015 12:00:00 AM	ADDRESS	34.07724	-118.25897	(((7/8/2015- CHANGES MADE TO APPROVED SET. ADDING PHOTOCELL TO DAYLIGHT AREA AND REVISED SWITCH BANK FOR CLARIFICATION. ALL CHANGES HAVE BEEN CLOUDED.)))ALTERATIONS IN RETAIL STORE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5061	17041-10000-17288	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/23/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	01/23/2024 12:00:00 AM	ADDRESS	34.03941	-118.25893	Installation of new fire alarm system in existing 15 floor high rise building.  Change of use from hotel to apartments.  Total system size = 733 devices, 7 control panels, and 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5062	19041-10000-50617	1540 N SKYLARK LANE	90069	4	147B169   499	5561004028	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.09909	-118.3877	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 33.63 KWac/41.04KWdc. SCOPE OF WORK INCLUDES 114 MODULES WITH MICROINVERTERS,  A NEW 200A LOAD CENTER INTERCONNECTED TO AN EXISTING 800A SERVICE. $0 permit fees due to senate bill 1222. per E.C	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5063	15041-10000-05565	9641 N OWENSMOUTH AVE	91311	12	201B105   204	2746016018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.24555	-118.60258	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 2784 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5064	17041-20001-07228	3540 W WILSHIRE BLVD	90010	10	132B193    47	5094001002	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.06157	-118.30171	Major revisions for approved plans.  Complete change of service details - consolidation of multiple services to (1) 3000A 480Y/277V service.  Revised architectural design throughout. (((change of use from retail/office to apartment/retail.  Adaptive reuse conversion of 13 story (high rise) commercial buiding with 205 units, using existing services.  Plan check for power and energy.BUILDING PERMIT # 17041-20000-07228)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5065	16041-30000-31950	5268 N TUJUNGA AVE	91601	2	171B173   346	2350017056	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.16676	-118.37882	Plan check new Fire alarm system in a 4 story hotel building 40 units. Total Fire alarm devices: 131 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5066	16041-10000-44680	3690 N BARHAM BLVD (BUILDING-G)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.14002	-118.34132	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5067	16041-10000-39766	3600 N BARHAM BLVD X	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Info Complete	11/10/2016 12:00:00 AM	ADDRESS	34.13829	-118.34154	PC FOR ADDITION OF LAUNDRY CIRCUIT WHICH IS COMBO UNIT WASHER AND ELECTRIC DRYER. TOTAL OF 182 UNITS BEING ALTERED. FULL PC FOR NEW CONNECTED LOADS GREATER THAN 400A this is permit for unit X	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5068	18041-20001-48158	8440 N BALBOA BLVD 104	91406	12	192B133   538	2689019016		North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.22397	-118.50243	02/15/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to reflect field installation.*****Original Work Description*****ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5069	13041-10002-20195	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	33.94502	-118.40714	TENANT IMPROVEMNTS TO TERMINAL 3 TO ACCOMMODATE THE RELOCATION OF US AIRWAYS INTO TERMINAL 3 SPACES. TITLE 24 PLAN CHECK ONLY.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. LOCATION G.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5070	12041-10000-06001	840 S SPRING ST	90014	14	127-5A209 228	5144016048	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.04233	-118.25416	PLAN CHECK POWER AND ENERGY.  2 STORY BUILDING WITH 3 TENANTS (TWO RETAIL AND ONE RESTAURANT) EMERGENCY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5071	10041-10000-19354	10250 W CONSTELLATION BLVD # 2850	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.05735	-118.41746	remodel office spceplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5072	11041-10000-16534	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	01/05/2012 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	33.89279	-118.28725	Converting idustrial space into retail.  Change of use.  Plan check is for energy and power. This includes the shell and goodwill, annas is issued under aseparate permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5073	14041-10000-28878	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	Pc for power and energy. Phase 4 (superstructure) of westfield century city shopping center renovation. Providing new high effecieny led lighting and control lighting on parking level 3-5. Provide power for new hvac and plumbing and elevators, and esclators. Total area 333773 sq ft.Planchecker to reverify the fees and the B apps#  for energy code. B# 13016-10000-16108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5074	12041-10000-17068	10 W CENTURY DR	90067	5	132B161   720	4319004***	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.05654	-118.4153	Plan check for power and energy. 7680 combined sq ft (4897 indoor). Century Restaurant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5075	17041-10002-45404	5401 W ADAMS BLVD	90016	10	123B177   929	5043001005	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.03264	-118.36032	PC FOR SHELL TI IN EXISTING SPACE ( PREVIOUSLY A RESTAURANT). SCOPE INCLUDES NEW LIGHTS AND CIRCUTIS (PERMIT PULLED UNDER 10001).TOTAL AFFECTED AREA 678 SQ.FT********************************THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5076	18041-10000-46873	437 N FRIES AVE	90744	15	030B205  1132	7418016007	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Apartment			12/11/2018 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	05/18/2022 12:00:00 AM	ADDRESS	33.77509	-118.26489	NEW METHANE MITIGATION SYSTEM IN (N) APARTMENT BUILDING, SCOPE INCLUDES (13) METHANE DETECTION DEVICES AND (5) HORN STROBES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5077	16041-10000-10919	1888 CENTURY PARK EAST 5th Floor	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	PIN	34.06160176	-118.41389445	TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING.  AREA OF WORK IS 5,077 SQ.FT.  PC FOR T-24 ONLY. *BUILD. APP. #16016-10000-06619	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5078	17041-10000-13255	5842 W CARLTON WAY	90028	13	148-5A191 256	5545010004	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			05/17/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	06/18/2020 12:00:00 AM	ADDRESS	34.10034	-118.31725	PC FOR POWER AND ENERGY. NEW 5 STORY  18 UNIT APARTMENT OVER 2 LEVELS OF BASEMENT GARAGE. SERVICE SIZE 1200 AMP. TOTAL AREA  10818 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5079	15041-10001-15984	6307 N BALCOM AVE	91335	5	177B129    67	2123021050	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	PIN	34.18417958	-118.52030624	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 5.89 KW DC ROOF-MOUNTED SOLAR ARRAY ON A RESIDENTIAL HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR 327ne-wht-d(1) INVERTER: ABB PVI-6000-OUTD-US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5080	13041-10011-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 31 REVISIONS : TEMPORARY REFFEED DISTRIBUTION BOARD HBHS FROM SWITCHBOARD D-PC. ORIGINALLY, HBHS WAS FED FROM SWITCHBOARD PF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5081	14041-20000-21060	12555 W JEFFERSON BLVD 2nd floor	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	33.97954	-118.41361	TI in (E) commercial office spaces in (E) low-rise office buildings (2nd floor east side).  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5082	18041-20000-11070	700 S FLOWER ST 19th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to (E) common area of highrise office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5083	19041-20001-34471	10987 W BLUFFSIDE DR PV 1	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.14185	-118.36953	PV2 BUILDING #4 (N) 20.4 KW AC/22.68 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (63) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5084	12041-10002-27531	17759 W CALLE DE PALERMO	90272	11	141B113    14	4431020003	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM			PC Approved	11/30/2012 12:00:00 AM	ADDRESS	34.07938	-118.57298	PV1:  9.36 KW roof mounted PV system for a single family residence was originally submitted and permited under 12041-10000-27531 with a 225 AMP bus.  System was never installed.  Owner has upgraded service to 400 AMP and has been finalized under 12041-20000-28805.  This supplimental now reflects the now existing 400 AMP service upgrade. <<<<<<<ROOF MOUNTED PV1 SOLAR INSTALLATION AND INTERCONNECTION TO MAIN SEVICE PANEL. STANDARD PLAN USING FRONIUS INVERTER AND SUNIVA OPTIMUS MODULES.>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5085	17041-10000-45426	725 S FIGUEROA ST 15TH FLOOR	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	T-24, PC FOR ENERGY ONLY. FULL FLOOR, TENANT IMPROVEMENT FOR COMMERCIAL OFFICE ON THE 15TH FLOOR. SCOPE INCLUDES NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 19180 SQ. FT. B#17016-10000-36718.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5086	10041-10000-06734	626 S SPRING ST #A	90014		127-5A211  43	5144001017	C2-4D		Central City	Downtown Los Angeles			Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM			PC Approved	04/13/2010 12:00:00 AM	ADDRESS	34.04516	-118.25148	Plan check T-24 energy for a TI of a bar	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5087	18041-10000-44908	1150 S OLIVE ST FLR 6TH	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.03962	-118.26181	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 6TH FLOOR.  14,816 SQFT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5088	19041-20000-34166	7800 S WESTERN AVE 1-20	90047	8	099B193   482	6018032001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	Apartment			08/29/2019 12:00:00 AM	07/09/2020 12:00:00 AM		Issued	07/09/2020 12:00:00 AM	ADDRESS	33.96893	-118.30879	1000A 240/120V 1ph-3w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5089	18041-10000-38058	10250 W CONSTELLATION BLVD 17&26th-Floors	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI IN CORRIDOR & ELEVATOR LOBBYS OF THE 17TH & 26TH FLOORS.  APPROX. 2,656 SF . INSTALLING NEW LED LIGHTING. T-24 ONLY. BLDG PERMIT: 18016-10000-24414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5090	18041-20000-07745	9113 N BALLARD DR	91311	12	198B101   336	2727024001	(T)(Q)RD3-1, A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.23566	-118.60696	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5091	18041-10000-41478	1062 N SWARTHMORE AVE 2-101	90272	11	129B125   462	4423016***	[Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.04804	-118.52468	FULL PLAN CHECK FOR FIRST TIME TI TO A EXISTING RETAIL, CONNECTING TO EXISTING 4000A SWITCHBOARDINSTALLING 1 NEW 225A PANEL AND 1 NEW 75KVA TRANSFORMERBUILDING PERMIT #18016-10000-35136	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5092	13041-20001-12757	21255 W BURBANK BLVD Suite 320	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM			PC Approved	06/27/2013 12:00:00 AM	ADDRESS	34.17432	-118.59446	((((6/13/2013: FIRST TIME TENANT FULL PLAN CHECK. T24 ALREADY APPROVED. THIS IS A PLAN CHECK ONLY, PERMIT HAS ALREADY BEEN PULLED UNDER APP#: 13041-20000-12770. SUITE NUMBER WAS CHANGED FROM 300 TO 320))))T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON THE 3RD FLOOR. 10,617SQRFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5093	16041-10000-00509	11254-11262 W OTSEGO ST	91601	2	171B173   948	2353013009	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.16278	-118.37653	Full PC, New 49-unit, 5-story apartment with 1 level abv ground parking and 2 levels of subterranean parking with 2000 amp service. One 800 amp switchgear feeds the common panels and a 1200 amp board feeds the units. 3 typical units. T-24 for indoor and outdoor, Total Sq. Ft. 40,695.fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5094	12041-10000-14319	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	(T)[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Public Safety Only			06/20/2012 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.09787	-118.31961	NEW FIRE WARNING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5095	15041-20000-35557	14006 W RIVERSIDE DR SPACE 206	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO NYX RETAIL AT WESTFIELD FASHION SQUARE. 1260 SQFT. SPACE #206	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5096	16041-20000-32806	11601 W WILSHIRE BLVD Suite 2100	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 only. Project site is the 21st floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,794 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5097	19041-20000-02023	17500 W BURBANK BLVD	91316	5	174B129   855	2254037019	RA-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.17213	-118.51506	new fire alarm system 139 devices plus facp.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5098	18041-10000-08046	18101 W LASSEN ST	91325	12	201B125    65	2731023047	A2-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.25018	-118.52797	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 22500 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5099	18041-10000-31009	15739 W VENTURA BLVD	91436	5	168B141   552	2261009012	C4-1L, R1-1, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.15563	-118.47654	New fire alarm system in a new building.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5100	14041-20000-10311	10831 N HASKELL AVE	91344	12	207B141   136	2667016031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.26745	-118.4762	PV1Install roof-mounted solar array on SFD, interconnect with main panel.System size: 6.25kW.(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(25) Canadian Solar #CS6P-250PX pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5101	17041-10000-13836	11912 W SHELDON ST	91352	6	198B169    80	2538002024	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.2401	-118.39236	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  80400 SQ FT. FOR INDOOR/OUTDOOR LIGHTING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5102	16041-10001-44955	9315-9317 W PICO BLVD	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Approved	02/01/2017 12:00:00 AM	ADDRESS	34.05542	-118.39328	EXPEDITE FEEPC FOR PV2 COMMERCIAL ROOFTOP SOLAR. SYSTEM SIZE IS 20KA AC USING CENTRAL INVERTER SYSTEM WITH TOTAL OF 43 MODULES AND POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5103	15041-10000-42060	1449 W 22ND ST	90007	8	123B197   115	5055001032	RD2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.03611	-118.29043	PV1, INSTALL 3.445 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (13) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB-PVI-3.0-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5104	16041-10000-21924	11275 W CHANDLER BLVD	91601	2	171B173    97	2350012920	PF-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.1683	-118.3771	PC for energy, title 24 to a coffee shop. New lighting and power. Newly connected load is less than 400 amps. Total sqft = 1951	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5105	17041-10000-44206	19431 W BUSINESS CENTER DR	91324	12	195B117    39	2783025099	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.23152	-118.55706	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5106	12041-10000-29919	9311 N LASAINE AVE	91325	12	198B129   206	2766017014	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.23998	-118.5129	PV1.  New 6.414 KW roof mounted PV system.  Applicant is using the standard plan.  Installing 30 modules, one inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5107	14041-10000-22072	747 W 115TH ST	90044	8	084B197    16	6088002019	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	33.92988	-118.28871	Installation of roof mounted solar PV array.  Total system size = 7.2 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5108	13041-10002-07268	824 S SAN JULIAN ST STE. 116	90014	14	126A211   300	5145009016	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			PC Approved	05/08/2013 12:00:00 AM	ADDRESS	34.03881	-118.25009	Title 24 only for coffee, food preparation only 273 sqft.  Permit is existing.  This plan check only for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5109	19041-20000-52435	9350 N TOPANGA CANYON BLVD	91311	12	198B101   200	2746013003	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	09/29/2020 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	34.2405	-118.60587	$0 fee per AB1414.PV3. Feed-In Tariff. Install 112 KW DC/101.6 KW AC CEC roof mounted PV system. (280) modules (LG400N2W) with (3) 33.3 KW inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5110	12041-10000-06407	12113 W SANTA MONICA BLVD 201A-201B	90025	11	126B145   665	4263028050	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM			PC Approved	04/04/2012 12:00:00 AM	ADDRESS	34.0406	-118.464	New lighting, receptacles, circuits to a retail space.  Load is less than 200A per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Change of use from Medical Office to Retail, occupancy load is 25.1 per architect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5111	17041-20000-11741	2828 N NEWELL ST Suite 5	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	Plan check for energy only. TI to existing office space (suite 5). New lighting (incl. emergency). 2,494sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5112	14041-20000-03004	7343 N RESEDA BLVD	91335	3	186B125   756	2118015003	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			02/03/2014 12:00:00 AM	05/30/2017 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.20424	-118.53632	New Mix-use - 2,280 sf Retail  & 40 Unit  Apt. Bldg. With 1st and 2nd floor private garage/retail and 3rd/4th/5th/6th floor 40-units Apt. bldg with bonus dencity.  New 1600A service, switchboard, panels, and branch circuit.  Plan check for power and energy.Note: Variance to separate fire alarm is submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5113	13041-20000-36073	19542 W VOSE ST	91335	3	183B117   441	2130031016	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.19825	-118.55936	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5114	19041-20000-43187	11601 W WILSHIRE BLVD STE 300	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 energy only, lighting. Total area: 3414 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5115	13041-20000-27880	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			Corrections Issued	10/08/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	T24 FOR EXISTING BUILDING. BUILDING PERMIT HAS ALREADY BEEN PULLED FOR THESE SIGNS. INSTALLING 14 NEW SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5116	17041-10000-33864	24904 S PRESIDENT AVE	90710	15	039B193   667	7439026005	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	33.79859	-118.30398	PC FOR PV SYSTEM WITH BATTERY STORAGE UNIT. PV SYSTEM 3KW AC USING CENTRAL INVERTER AND BATTERY STORAGE USING 5.8KW WITH 13.5KWH STORAGE. NEW COMBINING PANEL.PERMIT IS ZERO PER SB1110	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5117	11041-10001-09553	14708 W VENTURA BLVD	91403	5	166-5A149  67	2276002020	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.15154	-118.45347	UPGARDING THE SERVICE TO 2000 AMPS FOR AN EXISTING 2 STORY BUILDING.  The HP and Elevator are the only connected load.  New lighting for indoor and outdoor.  Tenant loads, wiring, and panels are future, plan check is required.  The installation of future panels is subject to plan check.    Full Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5118	14041-20001-18520	7921 N ALDEA AVE	91406	6	189B133   581	2204011010	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM			PC Approved	07/21/2014 12:00:00 AM	ADDRESS	34.21415	-118.50838	Fee is 0.00 base on Senate bill 1222 form 2012. Plan check only on an aproval plan for relocating (2) pieces of modules on the roof-top.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED TO MSP.(18) TRINA SOLAR TSM-255 MODULES(1) SOLAR EDGE PVI-5.0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5119	16041-20001-39083	6263 N TOPANGA CANYON BLVD	91367	3	177B101    20	2146001025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.18482	-118.60621	08-26-2019 Changes to an approved set of plan, Changes include addtion of lighting fixture in the unit and relocate receptacle in the units, addition of a lighting fixture in front each unit. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5120	18041-10000-28253	1500 E ANAHEIM ST	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.78074	-118.24357	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5121	13041-10000-31555	6101 W 83RD PL	90045	11	099B169  1401	4107027018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	33.96305	-118.39178	Changes are made asfolows: inverter has changed and new solar system is with optimizer system.for app# 13041-10000-24060.PV1.  Install 6.615 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter Power-One Aurora PVI-6000-OUTD-US-Z	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5122	10041-10000-09522	1200 W 7TH ST 2ND Floor	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.05136	-118.26616	TI IN AN EXISTING COMMERCIAL SPACE ON THE 2ND FLOOR. PLAN CHECK IS FOR POWER & ENERGY. Variance to separate fire alarm plans was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5123	18041-10000-41172	7956 N STANSBURY AVE	91402	6	189B153   505	2212027005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.21561	-118.43984	PLAN CHECK FOR 5.0KVA ROOF MOUNTED PV SYSTEM CONSISTING OF 1 CENTRAL INVERYTER(SE5000H-US) WITH 19 MODULES UNIG POWER OPTIMIZERS(P320)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5124	14041-20000-12377	9833 N SHOSHONE AVE	91325	12	201B129   124	2755010019	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.24954	-118.51846	Roof mounted PV system with system size 11.54KW.  (2) Transformerless inverters$0 permit fee is due to Senate Bill SB-1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5125	18041-20000-36635	18319 W DONMETZ ST	91326	12	210B125   206	2715026052	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.2737	-118.53272	PV1.  Install 10.24 kW DC roof mounted grid tied PV system.  (32) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5126	15041-10000-36381	12501 W SHERMAN WAY	91605	2	183B165    22	2324003047	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.20136	-118.40559	Remove HID light fixtures and replace new LED Fixtures. Sq ft =4524	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5127	19041-20000-46461	4821 N OAK PARK AVE	91316	5	168B133   194	2289004011	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.1584	-118.50467	PV1 PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 11.34 KW DC/10.31 KW AC CEC. ESS SIZE IS 54 KWH. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS, A 10KW INVERTER, (4) 5 KW BATTERIES AND (2) PANELS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5128	19041-10000-22122	9254 N WINNETKA AVE	91311	12	198B113   222	2761001***	(T)(Q)CM-1-MPR, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Apartment			06/11/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	02/29/2024 12:00:00 AM	ADDRESS	34.23884	-118.57087	*Zero permit fee per AB-1414/SB-1222*PV2. NEW ROOFTOP SOLAR SYSTEM AT AN APPARTMENT COMPLEX. SYSTEM CONSIST OF 320 MODULES (LG340N1C), 10 INVERTER (FRONIUS SYMO 12.0-3 12KW) CONNECTED TO A 600A SOLAR  PANEL. PANELS MARKED AS EXISTING ARE PRE-APPROVED IN THE ELECTRICAL SYSTEM OF THIS PROJECT, NOT YET INSTALLED. SYSTEM SIZE IS 108.8KWdc AND 120KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5129	12041-20000-01991	23200 W VANOWEN ST	91307	3	180B093    54	2036001012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.19352	-118.63181	pv system micro invereter single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5130	11041-20000-10874	6600 N TOPANGA CANYON BLVD #2074	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM			Corrections Issued	05/26/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to existing space.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under 11041-20000-10873	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5131	15041-10000-07740	1748 W CUMBRE DR	90732	15	012B189    24	7560028001	R1-1XL	Harbor	San Pedro	Coastal San Pedro, Northwest San Pedro	YES	2974.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM			Reviewed by Supervisor	03/25/2015 12:00:00 AM	ADDRESS	33.72945	-118.31623	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING ASSEMBLY HALL. DUE TO FIRE DAMAGE, THE ENTIRE ELECTRICAL SYSTEM HAS BEEN REPLACED. 2 600A SERVICES TOTAL OF 46K SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5132	13041-20000-03650	1550 W MANCHESTER AVE	90047	8	097-5A195 309	6037001050	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	33.95982	-118.30433	Medical clinic, new mammography imaging unit, new loads.  No lighting change.  Full Plan Check.  Building is State Licensed, OSHPD3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5133	14041-20000-02711	10625 N OAKDALE AVE	91311	12	207B113   141	2708020032	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.26315	-118.5671	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 17KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. CONNECTION TO 400A SERVICE.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5134	12041-10000-10104	5600 N OSTROM AVE	91316	12	174B133   617	2255021001	R1-1	South Valley	Encino - Tarzana	Encino		1390.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.17251	-118.50654	New 7.2kw rooftop photovoltaic  system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5135	16041-10000-15988	5224 W LOS ENCANTOS WAY	90027	4	151-5A195  20	5588037007	RE11-1	Central	Hollywood	Los Feliz	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.11134	-118.30405	PV1 9.81KW ROOF MOUNTED SYSTEM . 30 AC MODULES (E20-327-C-AC) AND PV MONITOR CONNECTED WITH A LOAD CENTER (60A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5136	18041-20000-42099	20800 W SHERMAN WAY	91306	3	183B109    78	2137020038	[Q]C1.5-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.20086	-118.58629	ti to an existing comercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5137	12041-20000-30051	4531 N DULCINEA CT	91364	3	165B101   184	2173015011	RE15-1-RPD-2.9-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.15038	-118.60653	New 2.88kw pv rooftop system for an existing single family residence.  ENPHASE M215 Microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5138	17041-10002-04636	20215 W RINALDI ST BLDG S4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.27499	-118.57438	Changes to an approved set of plans. All changes are clouded under delta 25 & delta 26. Changes include relocating landscape lights, and outdoor lights, reassigning circuits for exterior lights, and revising panel schedules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5139	10041-10000-13602	5160 N VINELAND AVE SUITE 101A	91601	4	171B173  1378	2419001042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	09/20/2010 12:00:00 AM	ADDRESS	34.16418	-118.37009	"DIVIDE SUITE 101 INTO TWO UNITS,  101-A  &  101-B; REMOVE EXISTING INTERIOR PARTITIONS, INSTALL 1 HOUR RATED PARTITION BETWEEN 101-A  & 101-B; INSTALL A SINGLE ACCOMMODATION REST ROOM; INSTALL INTERIOR PARTITION FOR 7' 0""  X  8' 0""  OFFICEplan chk is for title 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5140	11041-20000-25505	1640 W CARSON ST Suite A1	90501	15	051B193   965	7346003043	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	33.83132	-118.30759	T-24 plan check for remodeled tenant space suite A1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5141	11041-20000-03631	300 S GRAND AVE 4th Floor	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	04/15/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to a high rise building JP Morgan Chase.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5142	17041-10000-18881	10250 W SANTA MONICA BLVD # FC 24	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan Check for an existing space at the foodcourt of Westfield Century City, 'Everytable'.  Ste. FC 24.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5143	10041-10000-02534	5311 S CRENSHAW BLVD	90043	8	108B185   165	5006006022	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM			Reviewed by Supervisor	02/25/2010 12:00:00 AM	ADDRESS	33.99449	-118.33114	"NEW ""FRESH & EASY"" GROCERY STORE. PLAN CHECK IS FOR NEW SERVICE, PANELS, CIRCUITS, EQUIPMENT & ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5144	19041-10000-52556	5046 E YORK BLVD	90042	1	156A225   335	5477001010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.12105	-118.20538	TITLE 24 ENERGY PLAN CHECK ONLY. TOTAL EFFECTIVE AREA: 1278 SQFT. ADDING NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5145	18041-10000-42792	8940 W NATIONAL BLVD STE E	90034	5	123B169  1360	4312011034	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.03015	-118.38951	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5146	18041-20001-08768	16163 W NORDHOFF ST	91343	12	198B141   671	2671023018	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.2358	-118.48473	06/14/2018 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to massage parlor/tenant improvement. Total lighting area = 1,100 sq. ft.Note: Building application has been generated under 17016-20000-13938*****Previous Work Description*****(1) CIRCUIT AND (1) OUTLET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5147	12041-10000-09240	8000 W SUNSET BLVD	90046	5	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.09783	-118.36466	Remodel of an existing Movie Theatre with 200A of load per applicant.  Full plan check for Power and Energy is requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5148	12041-10000-08860	3412 W WINSLOW DR	90026	13	142-5A203  58	5427028009	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.08646	-118.27704	roof-mounted photovoltaic systems on roof of a duplex.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5149	17041-10001-07136	6200 S WILTON PL	90047	8	105B189  1022	6001020024	[Q]MR1-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	33.98318	-118.31471	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A STORAGE SPACE. TOTAL AFFECTED AREA IS 520 SQ. FT.  B#17016-70000-05161NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-07136	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5150	18041-10000-36990	11000 W VICTORY BLVD	91606	2	180B173   886	2336020036	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.18651	-118.37057	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5151	15041-10000-31374	4181 S MARCASEL AVE	90066	11	111B157   800	4233015005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	33.99896	-118.42182	PV1. NEW ROOF-MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 7.6 KW. (31) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-FRONIUS #PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5152	16041-10001-11970	9152 W JANICE PL	90210	4	153B165   368	4388018022	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.11352	-118.39572	*** Expedite FeePV1, rooftop solar installation on SFD, 20 kW AC.   (74) SUNPOWER X21-345       (2) SE10000A-US     SEP400 is being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5153	17041-20000-14494	7346 N ETHEL AVE	91605	2	186B161   541	2327015007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.20438	-118.41802	Plan check for power only. New 800 service for existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5154	13041-20000-25686	6721 N KURL WAY PV 1	91335	3	180B121   124	2126036021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.19235	-118.54243	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.5KW. PERMIT HAS BEEN PULLED UNDER THE FOLLOWING APPLICATION#: 13041-20000-16063. THIS IS A PLAN CHECK ONLY APPLICATION.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5155	19041-10000-03458	300 S GRAND AVE suite3840	90071	14	130-5A211   8	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.05283	-118.25116	Energy plan check for office T.I located on the 38th floor of a high rise building; Scope include new lighting and equipment with a total area of 1913-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5156	13041-10000-35469	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	POWER AND ENERGY. TERMINAL 2 RENOVATION PROGRAM, MOSTLY REPLACING PANELS AND BOARDS. F.A. VARIANCE TO BE FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5157	12041-10000-23975	3377 W WILSHIRE BLVD	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00, 2123.04	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.06193	-118.29742	TI for an ice cream shop. New lighting and branch ckt. EPC is for T24. (suite# 107)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5158	11041-10000-24446	1027 S DOREEN PL BLDG 3-2	90291	11	111B145   819	4243003033	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	33.99979	-118.45987	LINCOLN PLACE PROJECT. NEW 2 STORY 6 UNITS APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5159	18041-20000-13140	3303 W WILSHIRE BLVD 7TH FLR	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.06195	-118.29439	P Cfor T24 only for new lighting and receptacles for TI in office space on 7th floor. Total area is 9920sqft. B#18016-10000-06872.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5160	19041-10000-44481	15330 W NORDHOFF ST	91343	7	195B145   652	2654004050	[Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	34.23519	-118.46691	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFITS KITS OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5161	13041-10000-31783	315 E CULVER BLVD	90293	11	096B149   305	4116009055	[Q]C4-1D	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.95995	-118.44745	NEW FIRE ALARM SYSTEM TO 3-STORY COMMERCIAL BUILDING ( + ROOF ) . SPRINKLERED SYSTEM; WITH 28 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5162	15041-20001-14689	7032 N ENCINO AVE	91406	6	183B129   421	2228027006	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	34.19846	-118.51408	05-22-15 Change to approve set of plan. Changes include change to the layout of the modules. {{{{{{Plan check for PV system  roof mounted 4.0kWac system with 18 modules and 18 micro-inverter(Enphase )}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5163	12041-20000-24313	15200 W SUNSET BLVD	90272	11	129B125   727	4412002023	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM			PC Approved	10/15/2012 12:00:00 AM	ADDRESS	34.04624	-118.52472	1022 SF INTERIOR REMODEL ONLY FOR 5500 SF EXISTING CHASE BANK - CONVERT 5 OPEN OFFICE CUBICLES TO 4 PRIVATE OFFICES AND 1 CONFERENCE ROOM.  ADD 2 NEW OPEN OFFICE CUBLICLES AND TV MONITOR WALL BEHIND TELLER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5164	09041-10001-24232	12045 E WATERFRONT DR	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	01/15/2010 12:00:00 AM		Permit Finaled	04/23/2010 12:00:00 AM	PIN	33.98229149	-118.40627052	Plan check for revision to approved plans, addition of one methane sensor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5165	18041-10000-26979	701 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	33.7799	-118.24198	NOTE: FEES ARE $0 DUE TO AB 1414NEW PV SYSTEM MOUNTED ON CARPORTS WITH 2000 PV MODULES AND 25 INVERTERS WITH 480 VOLT OUTPUT.SYSTEM SIZE 870KWDC/750KWAC <<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03431	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5166	17041-20000-28151	310 S MARIPOSA AVE 1-43	90020	10	135B197   238	5502003016	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.06862	-118.29902	Plan check for roof-mounted solar pv system on apartment building.20kW ungrounded system (10+10).(66) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5167	17041-10000-46406	10966 N BATON ROUGE AVE	91326	12	210B121   599	2718010036	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2017 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	07/05/2018 12:00:00 AM	ADDRESS	34.26951	-118.55084	PC FOR NEW ESS INSTALLATION IN SFD. SCOPE INCLUDES SINGLE TESLA POWER WALL 2 (AC TYPE) WITH ADDITIONAL SUBPANEL.RESIDENCE HAS EXISTING PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5168	12041-10000-15069	3158 S HADDINGTON DR	90064	5	123B161   614	4318036019	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.03335	-118.41394	New rooftop photovoltaic system for an existing single family residence, using enphase M215 microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5169	18041-20000-38365	533 E DOLORES ST pv1	90744	15	036B209   221	7422025022	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	33.79446	-118.25702	pv1install roof mounted pv system sized 7.6KW AC with battery back up interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5170	10041-10000-22396	5670 W WILSHIRE BLVD # 820	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	ADDRESS	34.06222	-118.35208	Alterations of th elighting in the lobby and hallway in offices space.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5171	17041-10000-04959	10400 N SEPULVEDA BLVD	91345	7	207B145   772	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.25939	-118.46706	Plan check for Title 24 only T.I. existing sapce  retail. Total area: 2,705 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5172	19041-10000-05323	9001 N CANOGA AVE	91304	3	195B105    52	2779018031	[Q]MR2-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.23389	-118.59777	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5173	19041-20000-22468	8364 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM				PV1.  Install 2.8 kW roof mounted grid tied PV system for new home construction.  (8) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5174	17041-20000-22099	23116 W BIGLER ST	91364	3	171B097  1051	2074023003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.16102	-118.62962	Plan check for solar pv array, roof-mounted on SFD.4.8kW ungrounded system.(20) EnPhase M250 microinverters.(20) 305W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5175	13041-10002-30106	7320 N HESPERIA AVE	91335	3	186B125   806	2121003014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.2037	-118.5261	Expedited RSES plan check per applicant request.(((PV1, Install 11.75 kW DC roof-mounted solar array, interconnect with service panel. Multiple transformerless inverters. 47 modules HANWHA # HSL60P6-PB-4-250TW.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5176	10041-20000-08403	545 S FIGUEROA ST 5th-6th FL	90071	9	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	05/05/2010 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.0514	-118.2582	Plan check T-24 Energy (general/emergency) lighting for TI 5th & 6th  floor Jonathan Club.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5177	19041-10000-40227	11409 W ALBATA ST	90049	11	135B145   665	4365019008	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.06379	-118.46144	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 5KV PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 18 MODULES USING P320 OPTIMIZERS CONNECTED TO NEW 225A SERVICE SERVICE UPGRADE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5178	19041-30000-12845	22050 W VENTURA BLVD	91364	3	171B101   153	2169002032	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.01	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.16834	-118.60765	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the pharmacy of a CVS. Total lighting area = 1,162 sq. ft.Note: Building application has been generated under 19016-30000-06195	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5179	13041-10000-36062	936 S WALL ST STE #B	90015	14	126A211   408	5145017045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.03775	-118.2527	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 1125 SQ FT. REPLACING TOTAL OF 2 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5180	14041-10000-35567	725 S BIXEL ST 1-328	90017	1	130-5A207 631	5143004012	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			12/23/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.0501	-118.26506	Final fee is 0.00 due to Senate bill 1222, 225KW roof mounted PV system  for a six-story aparment complex. system including (936) Innotech Solar-260 modules, (10) combiner box and (1) central Solectria SGI 225PE inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5181	18041-10000-24387	3201 W WILSHIRE BLVD	90010	10	135B197  1225	5502025007	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2121.01	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			Reviewed by Supervisor	07/20/2018 12:00:00 AM	ADDRESS	34.06197	-118.29195	PLANCHECK FOR POWER AND ENERGY. NEW CVS PHARMACY.BUILDING PERMIT # 18010-10000-03341	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5182	18041-20000-40709	4348 N PONCA AVE	91602	4	165B181   254	2424027004	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.14957	-118.34915	Plan check for PV roof mounted system, system size: 12.96kW with 36 A Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5183	12041-20000-07314	533 E ROSE AVE	90291	11	111B141   277	4240005007	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM			PC Approved	03/30/2012 12:00:00 AM	ADDRESS	33.99878	-118.47305	TI for a restaurant. Plan check for energy and emergency lighting. 1325 conditioned sqft.  single story building.  chad requested to close the premit in order to get cfo permit not used chad isc the general contractor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5184	16041-20001-20464	14748 W KESWICK ST	91405	6	186B149    26	2210028008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.21015	-118.45472	(2/27/2017)changes to an approved set of plans.  revisions to panels A B C D to balance loads.  This is plan check only. See comments.....	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5185	16041-10000-36270	5150 W HOLLYWOOD BLVD	90027	13	148-5A195  92	5544015014	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.10161	-118.30232	T-24, PC FOR ENERGY ONLY. TI TO AN EXISITNG BAKERY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 765 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5186	13041-20000-20002	11412 N PORTER VALLEY DR	91326	12	213B121   639	2822035003	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.27828	-118.55143	New Enphase PV System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5187	16041-10000-16177	1612 E 55TH ST	90011	9	108B213   262	5105015001	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	33.99286	-118.24489	PV1 install 3.64 kw dc / 3.80 kw ac roof-mounted solar array  on a single family home.(14) modules: canadian solar cs6p-260(14) optimizers: Solaredge P300(1) inverter: Solaredge se3800a-us	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5188	14041-10001-10237	1719 W 253RD ST	90717	15	036B193   998	7410015***	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	33.79495	-118.30841	Expedited RSES plan check per applicant request.{{PV1.Install 4.5 kW DC roof-mounted solar array on a 2 story-house, interconnect with main service panel.(1) Transformerless inverter: POWER-ONE # AURORA PVI-3.6-OUTD-S-US-Z-A(18) Modules: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5189	17041-10000-06995	5855 W CENTURY BLVD LVL 2	90045	11	090B169    11	4125025039	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	33.94572	-118.38488	PC FOR ENERGY ONLY INTERIOR TI TO EXISTING HOTEL LOBBY, RESTROOMS, CIRCULATION, REGISTRATION AND LOBBY BAR. NEW LIGHTING AND POWER. AREA: 15,241.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5190	19041-10000-14636	1050 W ARROYO ST	91340	7	216B161   160	2514019014	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	05/15/2020 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	PIN	34.2881352	-118.41898074	NOTE: PERMIT FEES ARE $0 DUE TO AB 1414.PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 1410 MODULES (LG 400N2W), 723 OPTIMIZERS (P860), 4 INVERTERS ( SE 99.9K) AND 1 INVERTERS ( SE 33.3K). SYSTEM SIZE IS 432KWac AND 564.0KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5191	17041-10000-42129	12224 W MONTAGUE ST	91331	7	204B165   143	2537018028	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.25653	-118.39887	REPLACEOUTDOOR  LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5192	19041-20000-16599	6823 S LA CIENEGA BLVD	90045	11	102B173   135	4103001009	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	10/06/2020 12:00:00 AM	ADDRESS	33.97634	-118.37052	PLAN CHECK FOR NEW SERVICE TO NEW SMART AND FINAL AND 2 FUTURE COMMERCIAL BUILDINGS. SERVICE SIZE 3000A.M SCOPE OF WORK INCLUDES (1) 400A HOUSE PANEL, (1) 3000A SERVICE, (1) 1600A PANEL, A 3000A PULL SECTION. AREA IS A METHANE BUFFER ZONE. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 213,498 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5193	16041-30001-17525	1840 S CENTURY PARK EAST 3rd floor	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	Changes to approved set.  Changes to Title-24 sheets and changes single line (two new transformers added).      *****Original scope of work*****     T.I. to workroom and server room on 3rd floor of existing highrise building.  PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5194	16041-10000-25444	888 S FIGUEROA ST ste. 440	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.0465	-118.26225	Plan check for T-24 only. TI to an (E) office building. Install new lights and receptacles, total affected area: 5,286 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5195	17041-10000-25698	3902 W SUNSET BLVD	90029	13	147A191    82	5545015001	[Q]C2-1VL, [Q]C4-1	Central, East Los Angeles	Hollywood, Silver Lake - Echo Park - Elysian Valley	Hollywood Studio District, Silver Lake	YES	1909.02, 1959.01	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM			PC Info Complete	08/25/2017 12:00:00 AM	ADDRESS	34.0917	-118.27988	TITLE 24 PLAN CHECK FOR TENANT IMPROVEMENT (RETAIL TO RETAIL). TOTAL AFFECTED AREA 1375 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5196	18041-10000-21990	2029 S CENTURY PARK EAST 31st Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Issued	06/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN EXISTING RESTROOMS ON THE 31st FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5197	10041-10000-10216	1925 S SAWTELLE BLVD	90025	11	126B153   576	4261030012	C2-1VL, R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.04166	-118.44456	New multi story church with parking.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5198	14041-10000-17887	15047 W HARTLAND ST	91405	6	183B145   613	2220016010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Expired	08/09/2016 12:00:00 AM	ADDRESS	34.19538	-118.46136	Install roof mounted solar pannels on existing residential building.  Total system size = 5 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5199	18041-20001-23645	3420 E ALTA PL	90031	1	141A225   131	5208017039	[Q]RE20-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM			PC Approved	01/30/2019 12:00:00 AM	ADDRESS	34.08132	-118.20468	01-30-2019 Changes to an approved set of plan, changes include update conductor to aluminum. All changes has been clouded. Plan check only, permit covered under master application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5200	15041-20000-43762	13654 1/2 N DRONFIELD AVE	91342	7	228B149   728	2502022***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Refund in Progress	08/31/2016 12:00:00 AM	ADDRESS	34.32018	-118.45293	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (27) modules, (1) inverter, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5201	17041-20000-09050	1555 W SUNSET BLVD	90026	13	139-5A209 170	5419028004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.07667	-118.25669	ti to an existing comercial building single story corridor.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 1720.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5202	13041-10000-01792	111 E UNIVERSAL HOLLYWOOD DR # 2400	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM			PC Approved	01/23/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVMENT IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5203	11041-20001-01590	6600 N TOPANGA CANYON BLVD Suite FC10	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM			PC Approved	03/30/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check only, Delta 2 revision to T24 calculation and lighting plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5204	17041-10000-07830	7703 W WENTWORTH ST	91042	7	208-5A195  59	2552024041	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.26701	-118.30038	Plan check for PV roof mounted system 7.6kW with 37  modules and 1 inverter(7.6kW)(36)MODULES-HANWHA Q-CELLS#Q.PLUS G4.1(1)INVERTER-DELTA SOLIVIA 7.6 TL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5205	18041-10000-38744	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for an interior LED sign	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5206	12041-10000-04134	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	Replace generator paralleling switchgear. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5207	15041-10001-14856	1429 N TAMARIND AVE	90028	13	147A191   129	5545014013	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Approved	02/12/2016 12:00:00 AM	ADDRESS	34.09648	-118.3192	02/12/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES MADE UNDER DELTA 1. CHANGES INCLUDE REPLACING 2X4 LIGHT FIXTURES WITH LED LIGHTS.  (((((((((CHANGE OF USE FROM RESIDENTIAL TO COMMERCEIAL CHILD CARE CENTER, UNDER BUILDING NUMBER 15016 10000 04491.  TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1645.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5208	19041-20000-34210	3767 E CLARINGTON AVE	90034	5	120B165  1154	4313005033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.02303	-118.401	Tenant improvment to (e) offices in apartment building P.C for Title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5209	15041-10000-40346	1563 S FAIRFAX AVE	90035	10	129B173  1078	5068021010	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Expired	01/03/2018 12:00:00 AM	PIN	34.04794251	-118.367774	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING SINGLE INVERTER. TOTAL MODULES 28.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5210	15041-10000-43371	707 W WILSHIRE BLVD # 3920	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.04893	-118.2572	ALTERATIONS IN OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5211	17041-10000-24373	4094 S GLENCOE AVE	90292	11	108B153  1063	4230006003	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	33.99	-118.44273	"T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING SINGLE STORY OFFICE BUILDING. SCOPE INCLUDES TWO NEW PANELS, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS ""COMPLY WITH DEPARTMENT ORDER effective date03/08/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""B#17016-10000-13208"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5212	12041-20000-18138	16000 W LASSEN ST	91343	12	201B141   215	2671001903	PF-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	Apartment			08/02/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Expired	10/28/2014 12:00:00 AM	ADDRESS	34.24991	-118.48078	New fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5213	17041-20001-22690	10941 W OAK MOUNTAIN PL	91040	7	207B173   507	2528037015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	34.26248	-118.36884	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5214	16041-20000-32845	1021 N KAGAWA ST	90272	11	129B129   560	4423010020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.04844	-118.51837	permit fee $0.00 by state senate bill no.1222BATTERY STORAGE SYSTEM. + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5215	18041-20000-44928	1432 N TAMARIND AVE	90028	13	147A191   124	5545015061	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Issued	11/26/2018 12:00:00 AM	ADDRESS	34.09661	-118.31892	Fire alarm system for (N) 4-story 21-unit apartment building.  (102) devices with new FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5216	14041-10000-00750	1458 S SAN PEDRO ST #106	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in Fashion District retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5217	12041-10000-04109	1617 N VIEWMONT DR	90069	5	148-5A173 352	5558017043	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2012 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.10075	-118.37925	Plan check 12.8KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5218	18041-20000-15838	20642 W CHESTNUT CIR (#332)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.29324	-118.58409	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5219	12041-10000-15191	6615 W WILLOUGHBY AVE	90038	4	144B185  1182	5532015063	R2-1XL	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.0872	-118.33565	New rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5220	12041-10001-09732	688 S BERENDO ST	90005	10	132B197   183	5094008023	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			02/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.06036	-118.29399	CHANGES TO APPROVED SET OF PLANS. UPDATED HP RATING OF 4 MOTORS AND ADDED THREE NEW BRANCH CIRCUITS. ******************************************************12041-10000-09732 DESCRIPTION: PLAN CHECK POWER AND ENERGY NEW 7-STORY APT BLDG W/ 2 LEVELS OF SUBTERRANEAN PARKING GARAGES. 3000A SERVICE. SITE LOCATED IN METHANE BUFFER ZONE.NOT A HIGH RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5221	14041-20000-13007	17544 W RAYMER ST	91325	12	192B129    70	2787024012	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Expired	07/12/2016 12:00:00 AM	ADDRESS	34.22619	-118.51743	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.71KW INTERCONNECTED WITH MAIN PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5222	15041-20001-26423	13630 W SATICOY ST	91402	6	186B157   140	2214025004	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.20928	-118.42941	"05-04-2016 Change to approved set of plans. All changes have been clouded and marked as Delta 3. Changes include the addition ""VP "" of 12 panels in Panel ""PB"", add transformer to MSA and addition ""K1A"" panel to ""K1"".Scope of work corrected from previous - 1200A 277V/480Y service is (E) to remain   *****Previous Work Description*****{{{{{{{Plan check for power and Title-24 (energy).  Total area = 21,127 sq. ft.  T.I. to existing commercial space.  Complete electrical renovation for new restaraunt space.  (N) 1,200 A service.}}}}}}}}"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5223	15041-10000-34643	6301 W 3RD ST	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.07243	-118.35963	T-24, PC for energy to an existing restaurant. Existing service and equipment. Adding new lighting only. Sq ft = 1834	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5224	17041-10000-17203	5320 S VERMONT AVE	90037	9	108B197   552	5001005033	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	33.99348	-118.29133	RETAIL STORE 7-11. TI. COMBINE 2 SUITES INTO 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5225	15041-10000-14248	6500 N CANOGA AVE	91303	3	180B105    74	2148031018	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.1887	-118.59717	TI-24 TO (E) COMMERCIAL BUILDING. ADDING NEW LIGHTING. TOTAL SQ. FT. 24284	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5226	13041-10000-23946	8831 W VENICE BLVD	90034	10	123B169  1196	4312008041	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.03083	-118.38619	Tenant improvement of (E) 2-story rehabilitation center office.  Title 24 plan check only for lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5227	17041-10000-07504	5554 N CAHUENGA BLVD	91601	2	174B177   667	2417001041	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.17157	-118.36138	PC FOR FA SYSTEM WITH 12 DEVICES AND MAIN PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5228	19041-10000-09948	4490 E LINCOLN AVE Bld-5	90041	1	156A221   126	5474025006	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.12281	-118.21902	Plan check for power only, New 800A service 120/240 1ph, 3W to supply power to 10 tract home.No common space on this project. Tract home building plan check is under:17010-10000-00185/00186/00188/00189/00190/00191/00192/00193/00195/00196 <<(10) 3-STORY, TYPE VB, SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE. SMALL LOT SUBDIVISION PURSUANT TO TENTATIVE TRACT MAP NO. VTT-73291-SL.  A CERTIFICATE OF OCCUPANCY (TEMPORARY OR FINAL) SHALL NOT BE ISSUED UNTIL AFTER THE FINAL MAP HAS BEEN RECORDED. >>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5229	14041-20000-05149	12698 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	33.97714	-118.41552	PC FOR SERIES OF ROOF-MOUNTED,  PHOTOVOLTAIC SYSTEMS FOR NEW CONDOS. THIS SYSTEM IS SPECIFIC FOR UNIT 1. SYSTEM SIZE 3KW AC. SYSTEM IS TIED TO MAIN SERVICE SERVING OTHER UNITS. THIS IS PLAN CHECK AND PERMIT SUBMITTAL 1 OF 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5230	15041-10000-15056	6731 W LELAND WAY	90028	13	147A185   188	5547022008	RD1.5-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Apartment			05/18/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.09674	-118.33749	Per�Senate�Bill�No.1222, Fee cap reached, thus fee is $0.PV-2, ROOF MOUNTED PV SYSTEM. 136 MODULES AND TOTAL SIZE 30 KW-AC. INTERCONNECTED WITH MSP.(136) Q. PRO, BFR-G3(3) SMA 10 KW TRANFORMERLESS INVERTERS.Changes on plan to reflect calculated breaker sizes and fuse sizes.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5231	19041-20000-44565	515 S FIGUEROA ST ste 1100	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.05199	-118.25764	T24 PLAN CHECK, REPLACING LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 10281 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5232	19041-20000-19588	181 S VERMONT AVE	90004	13	138B197  1240	5518030003	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2113.20	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.07061	-118.29189	Plan check for power and energy for Tenant Improvement to existing restaurant, Total load exceed 400A, 800A Service existing to remain. Total area: 3030 sq ft. B#19016-10000-11837	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5233	18041-30000-03560	418 N NORTH FARING ROAD	90077	5	141B153    46	4358007026	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM			Reviewed by Supervisor	03/06/2018 12:00:00 AM	ADDRESS	34.08616	-118.43257	Plan check for Temp Service for existing SDF 1,200A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5234	14041-10000-35390	3400 W PICO BLVD	90019	10	129B189  1036	5072037001	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM			Reviewed by Supervisor	02/11/2015 12:00:00 AM	ADDRESS	34.04699	-118.3179	PC FOR POWER. CONSOLIDATING METERS. NEW 3000A DISTRIBUTION BOARD. KING TACO FAST FOOD RESTURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5235	17041-20000-43512	5342 W FOUNTAIN AVE	90029	13	144B193    63	5537003004	R3-1	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Apartment			12/04/2017 12:00:00 AM	03/16/2020 12:00:00 AM		Permit Finaled	09/20/2021 12:00:00 AM	ADDRESS	34.09488	-118.30619	Plan check for power and energy. New 800A 120/240V 3ph 4w service and (19) panels with loads. T24 area: 12,670sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5236	15041-10000-12765	20301 W RINALDI ST	91326	12	213B113   334	2701075***	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			04/28/2015 12:00:00 AM			PC Info Complete	04/28/2015 12:00:00 AM	PIN	34.27720551	-118.57780454	ADDING NEW EXTERIOR LIGHTING.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL HARDSCAPE AREA 15007.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5237	16041-10000-38744	9724 S HAAS AVE	90047	8	093A191   233	6057008039	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	33.9476	-118.31655	ROOF MOUNTEDPV1 SFD TOTAL SYSTEM SIZE 7.2 KW AC USING 2 CENTRAL INVERTERS AND TOTAL OF 20 SOLAR MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5238	19041-20000-42645	22865 S LOCKNESS AVE	90501	15	045B193   471	7347017061	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	33.81751	-118.30671	Plan check for 1200A Service upgrade, service only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5239	13041-10000-00385	426 S HILL ST	90013	14	129A211    18	5149025008	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM			PC Approved	01/07/2013 12:00:00 AM	ADDRESS	34.04946	-118.25094	this plan review incorporates in one set of plans tenant improvement of fire alarm system for this high rise building; permits were obtained but inspector requested to have one set of plans instead of separate plans for individual floors	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5240	15041-20000-05454	4554 N SHERMAN OAKS AVE	91403	5	168B145   983	2283023002	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.15345	-118.46892	Plan check for power and energy. Project site is being changed from retail to office building. Not a high-rise building. Project scope is the installation of (4) new panels and associated loads onto an existing 600-amp service, (5) AC units, and (1) elevator. Total lighting area = 7,003 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5241	15041-20000-23238	1000 W WILSHIRE BLVD Suite 1800	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	Title-24 plan check only.  Total area = 15,200 sq. ft.  T.I. to existing highrise commercial office space.  Lighting, recepticles, and HVAC for entire floor remodel.  New connected load is less than 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5242	14041-20000-11198	660 S FIGUEROA ST 1450	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Issued	04/29/2014 12:00:00 AM	ADDRESS	34.04953	-118.25947	T.I. to existing high rise building partial of 14th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5243	17041-10001-07856	6733 N FALLBROOK AVE	91307	12	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			Corrections Issued	04/21/2017 12:00:00 AM	ADDRESS	34.19198	-118.62363	PC ONLY FOT T-24, SCOPE INCLUDES T.I FOR ELECTRIC IN SALAD BAR RESTAURANT. TOTAL SQ. FT. 1983. FEES ARE PAID UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5244	17041-10000-22829	10800 S MAIN ST	90061	8	088-5A205  10	6073001033	C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.10	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	33.93811	-118.27367	Remove HID FIXTURE AND REPLACE WITH NEW LED FIXTURES. TITLE-24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5245	13041-10000-08288	9100 N LEMONA AVE	91343	7	198B149   623	2651003***	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.23581	-118.45871	PV1 TWO STORY. 26 MODULES AND 1 INVERTER, 6.5 KW TRANSFORMERLESS. ROOF MOUNTED SOLAR. [SOLAR MODULE: TRINA SOLAR  TSM-250PA05.08 ] [INVERTER: POWER-ONE PVI-6000-OUTD-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5246	15041-10000-28019	9220 N WINNETKA AVE	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	07/06/2017 12:00:00 AM		Issued	07/06/2017 12:00:00 AM	ADDRESS	34.23795	-118.57084	Ti to an existing 2 story bldg full build out. Pc for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5247	18041-20000-18234	2677 E THORPE AVE	90065	1	145-5A219 267	5453005006	R1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.09236	-118.22554	PV1.  Install 2.95 kW roof mounted grid tied PV system.  (10) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5248	17041-20000-00650	12113 N ADELPHIA AVE	91340	7	216B161    67	2514006022	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.29024	-118.41351	PV1.  Install 6.76 kW roof mounted grid tied PV system.  Central inverter standard plan.  In accordance with the requirements of 2014 NEC 690.12, array conductors extending more than 10' from the array will be disconnected from the array using a qualified rapid shutdown device - cutsheet attached to approved plans.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5249	17041-10000-44137	8352 N CANTALOUPE AVE	91402	6	192B153   625	2637030022	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.22301	-118.43567	New PV1, 5kW AC on a SFD. (22) modules, (1)SE5000H-US. Plan check using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5250	12041-10001-27812	4550 W PICO BLVD C314	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Expired	10/22/2015 12:00:00 AM	ADDRESS	34.04842	-118.33486	CRA CLEARED IN 12041-10000-27812. INVESTIGATION FEE HAS TO BEEN ADDED TO THE FINAL FEES.FIRST TIME TENANT  GNC AT THE MID-TOWN CROSSINGINITIAL PLAN CHK IS FOR TITLE 24 ; THIS APPLICATION IS FOR FULL PLAN CHECK FOR THE POWER INSTALLATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5251	17041-10000-24592	10001 S LOU DILLON AVE 101-205	90002	15	091-5A215 217	6046019917	OS(UV), RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	PIN	33.94622917	-118.23474955	New, 3-storym 8-unit apartment building. 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5252	15041-20001-16336	10530 W VICTORY BLVD	91606	2	177B177    90	2414019012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	34.18498	-118.36061	Experdite per applicant request[[[[[Plan check for PV 2 roof mounted system 30kW with 3 inverters and 120 modules]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5253	17041-20000-11056	700 S FLOWER ST 8th floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR T24 ENERGY . TENANT IMPROVEMENT FOR CORRIDORS AND RESTROOMS. 2281 SQFT. 8TH FLOO.R	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5254	10041-10000-14599	7300 W HOLLYWOOD BLVD	90046	4	147B181   182	5550016024	[Q]R5-1	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	11/01/2010 12:00:00 AM	ADDRESS	34.10144	-118.34913	New outdoor lighting. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5255	13041-20000-22890	20540 W SUPERIOR ST UNIT C	91311	12	201B109   243	2748003088	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.24626	-118.58135	RENOVATION OF EXISTING OFFICE SPACE. NEW LIGHTING. PC FOR T24 ENERGY ONLY. WORK DONE IN UNIT C. permit issued under this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5256	17041-20000-10651	4415 S CENTRAL AVE	90011	9	112-5A209  93	5108028023	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.00344	-118.25677	Plan check for Title 24 only. Project site is the basement of an existing commercial building. Project scope is a change of use from storage to parking/tenant improvement. Total lighting area = 6,283 sq. ft.Note: Building permit has been issued under 15016-20000-24267	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5257	17041-30000-13548	10016 S WILMINGTON AVE	90002	15	091-5A215  85	6046023004	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2017 12:00:00 AM			Corrections Issued	04/25/2017 12:00:00 AM	ADDRESS	33.94512	-118.23887	PLAN CHECK FOR ROOF MOUNTED PV.SYSTEM SIZE 5KAC INCLUDES 15 MODULES WITH OPTIMIZERS (CANDIANSOLAR 285M  / SOLAR EDGE P300ONE CENTRAL INVERTER (SOLAR EDGE  SE 5000)Contractor information will be provided	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5258	10041-10001-11210	3450 S WATT WAY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM			PC Info Complete	07/28/2010 12:00:00 AM	ADDRESS	34.02275	-118.28604	Change the priviously approved paln. Add corridor area to an existing permit. Plan check for T24. (((((((((((((((( T-24 and emergency lighting plan check for remodeled portion of the Thornton School of Music.  Inspector, please verify listing of the Wenger Rooms.))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5259	18041-20000-23652	1636 S HOLT AVE	90035	5	129B173   987	4303030008	R2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.04841	-118.37911	Plan check for power only. Project scope is the addition of (1) Tesla PowerWall onto an existing roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5260	14041-20000-17449	22300 W COHASSET ST	91303	3	186B101   400	2023021017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	07/19/2014 12:00:00 AM	ADDRESS	34.2065	-118.61249	PV1.  Install 5.2 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5261	14041-10000-11713	812 W 98TH ST	90044	8	093A199   269	6054005018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	33.94694	-118.2898	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM USING STANDARD PLAN. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5262	14041-10000-34726	8556 S EMERSON AVE UNIT 5	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	02/10/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 5 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5263	16041-10000-25523	1645 S WESTERN AVE	90006	10	126B193   319	5073012031	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.0429	-118.30925	T-24, PC FOR ENERGY ONLY. EXTERIOR BUILDING RENOVATION. SCOPE INCLUDES NEW EXTERIOR LIGHTS. TOTAL AFFECTED AREA IS 172 SQ. FT. B#16016-10000-00951	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5264	19041-10000-21092	15316 W EARLHAM ST	90272	11	126B125   911	4412021037	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.03776	-118.52763	[E-PLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM WITH ENERGY STORAGE SYSTEM  SYSTEM CONSIST OF 1 CENTRAL INVERTER(SE7600H), 25 MODULES USING P400 OPTIMIZERS, AND 1 TESLA POWER WALL (5KVA)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5265	16041-10000-41990	1820 W SLAUSON AVE	90047	8	108B193  1398	6001001024	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.98794	-118.31101	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 32800 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5266	18041-20000-08587	149 E 78TH ST	90003	9	099B205   401	6022007029	R1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Issued	03/08/2018 12:00:00 AM	ADDRESS	33.96888	-118.27222	pv2install roof mounted pv system sized 1.5kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5267	18041-20000-24016	17028 W DEVONSHIRE ST	91325	12	204B133   214	2694001031	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.25731	-118.50316	Plan check for Title 24  energy only in existing space T.I. hair salon. Total area: 1313 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5268	13041-20000-34739	545 N KENMORE AVE #1-16	90004	13	141B197   932	5520009008	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Apartment			12/13/2013 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.08034	-118.29695	NEW 16 UNIT APARTMENT BUILDING. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5269	14041-10000-09232	12111 W CLARKSON ROAD	90064	11	120B153  1190	4257014045	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.02145	-118.44361	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(18)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5270	19041-20000-33859	14744 W OXNARD ST	91411	4	177A149   173	2244009034	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.1792	-118.45457	ELECTRICAL SERVICE REPLACEMENT AND NEW DISTRIBUTION EQUIPMENT. (FUTURE LOADS).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5271	19041-10000-17019	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	11/20/2020 12:00:00 AM	ADDRESS	34.06281	-118.2731	Full plan check for Tenant improvement to (E) medical clinic space for OSHPD 3 dialysis clinic. area of scope is 3486SF. scope includes adding a new 400A switchboard thro a 150kva xfrmr.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5272	19041-20001-06382	9645 N ORION AVE	91343	7	201B145   496	2656013017	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.24611	-118.47198	Expedited plan check fee.PV1.  Install 11.10 kW roof mounted grid tied PV system with 9.8 kWh energy storage system.  (37) modules with 7.6 and 3 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5273	14041-10000-27207	5215 N EAGLE DALE AVE	90041	14	163-5A217  45	5680028008	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	34.14332	-118.22836	INSTALL 2.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(8) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5274	13041-10000-21015	5655 N COMO CIR	91367	3	174B101  1447	2146035***	(Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.17437	-118.61091	(((changes to approved set: 1 module added and changed layout of panels because of added canopy. charged per applicant)))PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS. TOTAL SYSTEM SIZE: 4.251KW. [INVERTER: POWER ONE AURORA PVI-4.2-OUTD-US] [SOLAR MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5275	11041-20000-07483	4553 S GLENCOE AVE 155	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/13/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	05/20/2011 12:00:00 AM	ADDRESS	33.98415	-118.43328	T.I.  RELOCATION OF LIGHTING FIXTURES.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5276	14041-10000-27255	420 E BOYD ST	90013	14	129A213   362	5147006001	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Closed	01/21/2020 12:00:00 AM	ADDRESS	34.04601	-118.24206	New fire alarm system including (1) panel and 90 devices. in a commercial building with a 2-storie and a 5-storie attached together.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5277	12041-10000-11742	6100 W CENTER DR #1000	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	33.97733	-118.3922	"T.I. to an existing 12-story office building.  Relocate lights, new downlights,.  New receptacles, motion sensors, and partition feeds.  Load is less than 400A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5278	14041-20001-28383	15766 W COBALT ST	91342	7	222B141   255	2604014076	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM			PC Approved	11/25/2014 12:00:00 AM	ADDRESS	34.30269	-118.47413	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.4KW INTERCONNECTED WITH MSP.(28) SUN POWER SPRE20 MODULES(2) POWER ONE PVI-4.2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5279	18041-10000-31832	654 N VIRGIL AVE	90004	13	142-5A201 290	5539026035	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.08334	-118.28667	NEW FIRE SYSTEM FOR 24-UNITS CONDMINIUM BUILDING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5280	14041-10000-07237	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	33.98179	-118.40283	METHANE MITIGATION PLANS. BUILDING 1 OF 2. ELECTRICAL PLANCHECK APP # 13041-10000-35614.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5281	14041-10000-18067	2460 E 12TH ST #4-A	90021	14	120A217   143	5168005021	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.02255	-118.22799	Title 24 plan check only.  Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5282	13041-20001-31932	9822 N AURA AVE	91324	12	201B117   209	2761010034	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	12/10/2013 12:00:00 AM	ADDRESS	34.24881	-118.5543	(expedite) PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC 48 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5283	14041-10000-25272	1150 S BEVERLY DR	90035	5	132A167   103	4330031040	C2-1VL-O, R4-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Public Safety Only			09/15/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.05621	-118.39569	NEW FA SYSTEM FOR RENOVATED HOTEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5284	19041-20000-17198	3536 N LOWRY ROAD	90027	4	153A203    29	5592008001	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.1156	-118.27781	PLAN CHECK FOR ADDITION TO EXISTING SFD WITH EXISTING PV. SCOPE OF WORK INCLUDES 1 NEW 13.5KWH TESLA POWERWALL AND A NEW 125A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5285	19041-10000-51618	352 S WESTMORELAND AVE	90020	13	135B197   453	5501023001	R1-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.06747	-118.28776	New PV1 roof mounted installation with a system size of 4.68KW DC/ 7.6KW AC, 12 modules (JKM390), 12 Power Optimizers (P400), 1 central inverter (SE7600H-US) and existing service of 225A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5286	13041-20000-23762	1345 W 251ST ST	90710	15	036B193   123	7410026056	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	33.79685	-118.3005	PV1 TRANSFOMERLESS SYSTEM. 21 MODULES AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5287	18041-20001-32872	19916 W TURNBERRY DR	91356	3	162B113    68	2180020006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	34.14091	-118.56751	expeditepv1install roof mounted pv system sized 12.8KW AC interconnected with msp.(42) 325 watt modules(2) inverters salivia	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5288	10041-10000-23333	12920 S FIGUEROA ST	90061	15	081B201   307	6132015031	[T][Q]M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM			Corrections Issued	11/22/2010 12:00:00 AM	ADDRESS	33.91479	-118.28252	T-24 lighting plan check for grocery store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5289	14041-20000-23417	10901 W VENTURA BLVD	91604	2	162B173   525	2366022022	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.14011	-118.368	replace light fixtures on existing track less than 10 %	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5290	17041-10000-36397	735 S FIGUEROA ST Suite #100	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Issued	10/10/2017 12:00:00 AM	ADDRESS	34.04878	-118.26079	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING GYM. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3212 SQ. FT.  B#14016-20000-17041	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5291	15041-10000-24485	6255 W SUNSET BLVD SUITE 920	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR ENERGY ONLY FOR TI OFFICE IN A HIGHRISE BUILDING. SCOPE OF WORK ON SUITE 920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5292	14041-10000-17381	777 S FIGUEROA ST SUITE 3600	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.04828	-118.26116	Title 24 plan check only.  Total area = 12,037 sq. ft.TI for existing commercial highrise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5293	13041-10001-03942	735 S FIGUEROA ST #118	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	DELTA 1 REVISIONS- CHANGES INCLUDE ADDING APPLIANCES, NEW CIRCUITS AND REPLACE A TYPE OF LUMINAIRE; ALL CHANGES ARE BUBBLED AND IDENTIFIED ON THE PLANS AS DELTA 1PLAN CHECK ONLY(((((((((FIRST TIME TENANT IN COMMERCIAL SPACE INEXISTING  FOOD COURT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5294	12041-10000-10626	3601 S WATT WAY	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.02113	-118.28752	Plan check mandatory measures T-24 Energy. All lighting are existing to remain. USC Grace Ford Salvatori classroom remodel #101, 104, 105, 107, 108, 109, 116, 118, 201, 202, 204, 205, 210, 212, 213, 220, 221, 222, 223, 228, 229.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5295	17041-10000-34984	1373 N MURCHISON ST	90033	14	132A227    46	5202011028	RD1.5-1	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.05734	-118.19723	REPLACE HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5296	19041-20000-09404	1888 S CENTURY PARK EAST Suite 1500	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.06104	-118.41402	Plan check for Title 24 only. Project site is the 15th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 14,628 sq. ft.Note: Building application has been generated under 19016-10000-07249	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5297	16041-10000-18004	1216 E 43RD PL	90011	9	114A211   453	5115035008	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM			Corrections Issued	05/23/2016 12:00:00 AM	ADDRESS	34.0047	-118.25367	PV1, installing new 3.92 kw dc roof mounted solar array. single family house. (12) Modules: sunpower spr327ne-wht(1) Inverter: power one pvi-3.8-outd-s-us****REQUESTED TO GET FIRE DEPT. APPROVAL ON THELOCATION OF THE MAIN SERVICE PANEL (DM)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5298	16041-20001-25568	7722 N FAUST AVE	91304	12	189B097  1093	2013031021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.21069	-118.62032	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM.  A NEW PV SYSTEM WITH BATTERY BACKUP.  JLM ENERGIZR 100 SMART INVERTER. SYSTEM SIZE: 8.8KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5299	15041-10000-06556	555 W 5TH ST SUITE 610	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2700.  SCOPE OF WORK TO BE PERFORMED IN SUITE 610	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5300	16041-20000-00350	11431 N HELA AVE	91342	7	213B169   857	2530033013	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.27734	-118.38539	PV1. Install roof mounted PV system sized 2.5 kW. Interconnected with main service panel.(10) Sunmodule SW 285 Modules(10) Enphase M250 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5301	13041-20000-04036	22327 W HART ST	91303	3	183B101   293	2024037001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.19778	-118.61341	"Plan check for solar. Please include service upgrade during ""inspection"" fee period."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5302	19041-10000-49147	7560 WORLD WAY WEST	90045	11	087B157    97	4129026911		West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	02/04/2020 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	PIN	33.93790872	-118.42837934	FULL PLAN CHECK FOR FIRST TIME TENANT AT LAX. SCOPE INCLUDES NEW EQUIPMENT AND LOADS CONNECTED TO EXISTING 1600A 3PH 4W DISTRIBUTION BOARD. SCOPE ALSO INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1104 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5303	19041-10000-40899	8054 N HESPERIA AVE	91335	12	189B125   167	2101015010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.21724	-118.52618	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 18 MODULES (HANWAHA Q-CELL 285W), 18 OPTIMIZERS (SE 320) AND 1 CENTRAL INVERTER (SE 3800H-US). SYSTEM SIZE IS 5.130KWdc AND 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5304	15041-10003-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta 35 CHANGES TO PERMITTED SET OF PLANS ; SCHEDULES TO PANELS CHANGED TO SHOW CIRCUITS REMOVED AND FEW CUIRCUITS ADDED ; FLOOR PLANS REVISED TO SHOW CHANGES ALL CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA 35 CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5305	17041-20000-02146	4001 W SUNSET BLVD	90029	13	145-5A201 293	5429010029	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.09271	-118.28035	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600-amps and tenant panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5306	11041-10002-13005	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Issued	03/07/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	Delta 4 changes to approved plans.   Remove existing booster heating, heat pumps, trash compactor, show existing circuits in panel schedule for reference, and additional branch circuits in HA and HLA panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5307	18041-10000-28981	8920 S BROADWAY	90003	8	094-5A203  49	6040029016	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.95494	-118.27797	TI IN AN EXISTING COMMERCIAL AREA. TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5308	14041-10000-27686	1918 W EL REY ROAD	90732	15	018B189   351	7559022005	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	33.74077	-118.31819	PV1 Standard Plan, 8KW roof-mounted system including (2) inverter and (37) Kyocera KD255 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5309	11041-10000-10422	12730 S FIGUEROA ST	90061	15	081B201   254	6132019042	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM			Corrections Issued	05/20/2011 12:00:00 AM	ADDRESS	33.91687	-118.28256	T24 plan check only.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5310	10041-10000-16635	18564 S WESTERN AVE	90248	15	060B193   210	6108001055	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	33.86223	-118.30895	OUTDOOR LIGHTING CALCULATIONS FOR A PARKING LOT FOR A TOYOTA DEALERSHIP. PLAN CHECK IS FOR T-24 ENERGY CALCS.  BUILDING PERMIT # 10020-10000-01591.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5311	19041-10000-32304	9601 N LURLINE AVE	91311	12	201B109   271	2748003090	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.24465	-118.5843	REPLACE  EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY AND REPLACE FLUORESCENT TROFFER TO LED RETROFIT KIT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5312	15041-10000-12216	2001 W 60TH ST	90047	8	105B189   475	6001013010	M1-1, M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	33.9853	-118.31372	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5313	15041-10001-03361	6423 N ALDEA AVE	91406	6	180B133   482	2230021011	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2015 12:00:00 AM			PC Approved	03/17/2015 12:00:00 AM	ADDRESS	34.18754	-118.50804	Expedite per customer request.(((PV1 8.4KW roof-mounted system including (2) Power One PVI-4.2 inverters & (30) SunPower SPS-327NE modules interconnecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5314	12041-20000-10896	7033 N QUARTZ AVE PV1	91306	3	183B117   400	2135013021	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.19838	-118.56455	New roof mounted P.V. system (5.13 KWdc) with monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5315	14041-20000-32510	13122 W PAXTON ST	91331	7	213B161   715	2533002005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.27898	-118.41858	pv1install roof mounted pv system sized 6.0kw interconnected with msp.(18) sunpower 327w modules(1) aurora 6k transformerless inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5316	18041-20000-44308	11373 N FERRARA LANE	91326	12	213B109    77	2701049037	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.27837	-118.58086	PV1.  Install 4.29 kW DC roof mounted grid tied PV system.  (13) modules with 5kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5317	19041-20000-44164	7415 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.2052	-118.49233	$0 permit fee due to SB1222 and AB1414Plan check for PV, PV system size: 163.2KW DC, 148.05 KW AC CEC with (408) PV Modules and 4 inverters(33.3KW), Service size: 400A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5318	13041-20000-12493	4511 N NOGALES DR	91356	3	168B121   524	2177011014	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.1534	-118.54215	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 8.850KW NEGATIVELY GROUNDED. [PV MODULE: LG260S1C] [INVERTER: (1) SUNNY BOY SB5000US (1) SUNNY BOY SB2000US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5319	15041-10001-41295	9600 N LURLINE AVE	91311	12	201B109   290	2748040027	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.24455	-118.58404	EXPEDITE FEESNEW DESIGN. INSTALLING 3 INVERTERS. 108 MODULES TOTAL. SYSTEM SIZE 34KW AC. LINE SIDE CONNECTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5320	12041-20000-09724	9041 N RESEDA BLVD	91324	12	195B125    56	2770004006	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Approved	04/27/2012 12:00:00 AM	ADDRESS	34.23483	-118.53634	T-24 lighting plan check for Wingstop restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5321	18041-10000-27176	1901 W BLAKE AVE	90039	13	147A213    23	5442010027	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			07/24/2018 12:00:00 AM	02/04/2020 12:00:00 AM		Permit Finaled	07/25/2022 12:00:00 AM	ADDRESS	34.09874	-118.24353	New 1600A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction. Plan check for power and energy. Building Permit: 17010-10000-01880	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5322	15041-10000-35568	949 S FIGUEROA ST	90015	14	127-5A207   6	5138003014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM			PC Approved	10/29/2015 12:00:00 AM	ADDRESS	34.04527	-118.26392	PC FOR ENERGY. NO CHANGE OF USE. EXISTING FAST FOOD RESTURANT. (EJ'S BITES) TOTAL AREA 2477 SQ FT.  PERMIT FEES WERE PAID UNDER EXPRESS PERMIT 15041-10000-18231	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5323	12041-20000-18246	15655 W ROSCOE BLVD Bldg G	91343	12	192B141   429	2673013032	[Q]CM-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.22155	-118.47417	New roof (Building-G) mounted P.V. system with 25.92 KWdc.Note: Some modules are mounted on Building-F (12041-20000-18243) and Building-H (12041-20000-18249).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5324	10041-20000-12259	1336 N EDGEMONT ST	90027	13	147B197   944	5543019002	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	07/02/2010 12:00:00 AM		Permit Finaled	08/24/2010 12:00:00 AM	ADDRESS	34.09645	-118.29596	OUTDOOR LIGHTING FOR PARKING AREA. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5325	12041-20000-28394	4112 N WHITSETT AVE	91604	2	165B165  1171	2367009010	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			11/27/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.14529	-118.40503	New fire alarm for a new apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5326	13041-10000-33149	13156 W VAUGHN ST	91331	7	213B161   125	2524006027	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	PIN	34.28377072	-118.41914898	PV1.  Install 4.25 kW roof-mounted PV system, interconnect with main service panel.  17 modules: Trina Solar TSM-250PA05.18.  Transformerless inverter: SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5327	18041-20001-48513	555 S MATEO ST Bldg 1	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/09/2020 12:00:00 AM		Permit Finaled	02/23/2022 12:00:00 AM	ADDRESS	34.03943	-118.23302	Revisions to approved plans. All changes are clouded unded delta 1. Major architectural layout revisions, recircuiting of loads, lighting design changes, revising title 24 calculations, revising single line diagram, and revising service load calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5328	14041-20000-21767	11473 N VIKING AVE	91326	12	213B121   459	2871004008	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.27984	-118.54545	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(20) SUN MODULE SW 250(20) ENPHASE 215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5329	17041-10000-38774	6925 N SHOUP AVE	91307	12	183B101   524	2024015055	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.19621	-118.61488	New rooftop solar system, 6kW AC system. (19) AC modules, (1) load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5330	15041-10001-27928	17508 W VINTAGE ST	91325	12	204B129   535	2734019009	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.25196	-118.51611	EXPEDITED RSES PLAN CHECKPER APPLICANT REQUEST.<<<PV1, INSTALL 10.46 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: SUNPOWER SPR327NE(2) INVERTERS: ABB PVI-5000-OUTD>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5331	19041-10000-10411	1040 N LAS PALMAS AVE STAGE 1	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5332	12041-10000-01744	15485 W BRIARWOOD DR	91403	4	163-5A145  94	2281019002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2012 12:00:00 AM			PC Approved	01/24/2012 12:00:00 AM	ADDRESS	34.14215	-118.47061	PLAN CHECK 5.5KW ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING. PERMIT UNDER #11041-10000-26310. ZONING APPROVAL UNDER PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5333	19041-10000-41274	17144 W BURTON ST	91406	6	192B133   351	2204003003	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.22007	-118.50705	Plan check for a PV1 5KW AC / 6.75KW DC roofmounted system. Scope includes (1) inverter, (18) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5334	19041-10000-27500	7151 N LANKERSHIM BLVD	91605	2	183B169   144	2321003020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.20066	-118.38813	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5335	19041-20000-42054	3237 S BUTLER AVE	90066	11	120B157   993	4250019012	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.02113	-118.43127	Plan check for PV roof mounted system and energy storage system, PV system size: 3.77KW DC, 3.8KW KW AC with 13 PV Moduels and 1 inverter(3.8KW) and 1 LG Chem battery, new sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5336	18041-10000-19490	330 N WESTLAKE AVE	90026	13	136-5A207  71	5157025043	(T)(Q)RAS4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	08/17/2020 12:00:00 AM	ADDRESS	34.06951	-118.26652	PC FOR NEW FIRE ALARM IN A 6 STORY APARTMENTS BUILDING WITH 200 APARTMENTS. SCOPE INCLUDES NEW FACP AND 592 DEVICES. B# 13010-30000-04342	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5337	19041-20000-19954	14747 W ORACLE PL	90272	11	132B129    36	4422033004	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM			Reviewed by Supervisor	06/07/2019 12:00:00 AM	ADDRESS	34.05569	-118.52046	New 27 kWh energy storage system with (E) PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5338	14041-20000-22361	8845 N OAK PARK AVE	91325	12	195B133   242	2690012007	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.23162	-118.50561	New roof mounted PV system with Optimizers.  Total system size 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5339	16041-10000-02384	1922 W 73RD ST	90047	8	102B193  1574	6017007005	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	33.97355	-118.31195	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac. (16)MODULES-SUNMODULE PRO-SERIES SW250(1)INVERTER-FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5340	17041-10000-21774	6001 S HOOVER ST	90044	9	105B197   435	6004009034	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.98532	-118.2872	TItle 24 plan check.  Replace existing fixtures with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5341	17041-20000-30882	9999 N WORNOM AVE	91040	7	204B177   216	2543027003	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.25223	-118.35283	Plan check for solar pv system, roof-mounted on SFD.17.6kW ungrounded system. (60) 330W pv modules.Each module has a 400W power optimizer.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5342	18041-10001-24391	18021-18025 W VENTURA BLVD	91316	5	171B125   350	2162005131	(Q)C2-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM			Corrections Issued	01/14/2019 12:00:00 AM	ADDRESS	34.16487	-118.52499	"Supplimental pc for delta 2 changes only. Changing Panel ""A"" from fully rated to 42KAIC series rated. Inspector to verify main servive AIC rating. <<<<Original Scope of work: PLAN CHECH FOR POWER AND ENERGY FOR - TI OF EXISTING SHELL AND INTERIOR FOR A CAFE WITH DRIVE THRU. NEW CONNECTED LOAD >400A CONNECTING TO AN EXISTING 600A SERVICE USING 3 NEW 200A PANELS, TOTAL AFFECTED AREA = 2420 SF.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5343	18041-10000-29702	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.05494	-118.23752	Energy plan check for a coffee shop tenant Improvement to existing Restaurant. Scope includes new ighting, and equipment with a total area of 1226-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5344	14041-10000-35600	21514 W NORDHOFF ST	91311	3	195B105    10	2779018037	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.23525	-118.59942	Title 24 plan check only.  Total area = 11,188 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5345	16041-10000-03640	4923 N EAGLE ROCK BLVD	90041	14	160-5A221  36	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM			PC Info Complete	02/01/2016 12:00:00 AM	ADDRESS	34.13592	-118.21534	T-24, PC FOR ENERGY ONLY. TI FOR CHIROPRACTOR FACILITY; CHANGE OF USE FROM RESTAURANT TO CHIRO. TOTAL AFFECTED AREA IS 871 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5346	18041-10001-23128	550 S PALOS VERDES ST	90731	15	015B201    36	7455026048	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Apartment			05/09/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	33.73963	-118.28119	fire alarm system and devices are changed to a one of different manufacturer(((INSTALLATION OF A FIRE ALARM SYSTEM. 2 FACP, 19 RPS, 1141 DEVICES)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5347	12041-10000-28835	5900 N RUDNICK AVE	91367	3	177B101   223	2146022016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.17839	-118.61202	7.92 kw roof mounted PV for a single family. (PV1)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5348	13041-10000-01791	1611 S BEVERLY GLEN BLVD 1-6	90024	5	132B157  1267		[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.05941	-118.42528	FA FOR 4STORY APT W/ PKG GARAGE. r2 type v , b type iii, s-3 type i	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5349	19041-10000-48361	2763 N LAUREL PASS	90046	4	156B169   331	5565040007	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.12148	-118.3828	0$ FINAL FEES PER AB1414[EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM OF 15.51KW DC/ 14.26KW AC (CEC),  47 MODULES (PANSONIC GROUP 330), 47 SOLAREDGE POWER OPTIMIZERS (P400), 1 CENTRAL INVERTER (SE11400-US) CONNECTED TO A EXISTING SERVICE RATED 200A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5350	16041-20000-31609	10900 W VINEDALE ST	91352	6	195B173   568	2408010027	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.22758	-118.36792	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (43) modules, and (1) combiner box. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5351	16041-20000-39508	2929 S WESTWOOD BLVD	90064	5	123B157   980	4254003005	R1-1	West Los Angeles	West Los Angeles	Westside		2717.01	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM			PC Approved	11/08/2016 12:00:00 AM	ADDRESS	34.03128	-118.42169	tit o an existing commercial building single story.  adding new lighitng indoor/outdoor new controls to new panels.  newly connected load <400 amps.  plan check for energy and em lighitng only.  total square footage 960.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5352	18041-30000-20864	6222 W WILSHIRE BLVD 400	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.06309	-118.36418	PLAN CHECK FOR ENERGY (T24) ONLY, TENANT IMRPOVEMENT TO (E) OFFICE BUILDING STE.400. TOATL AREA: 12,165 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5353	15041-10000-36806	12615 W BEATRICE ST	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	33.98049	-118.41636	UPGRADE SERVICE TO EXISTING EMPTY BUILDING; FEEDERS ARE STUB-UP;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5354	13041-10001-26323	17271 W AVENIDA DE LA HERRADURA	90272	11	141B117    44	4431013044	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.07889	-118.56267	][][]EXPEDITED PER APPLICANT REQUEST ][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON STANDARD PLAN . 2 STRINGS, SYSTEM SIZE IS 4.25KW DC WITH (17) MODULES: TRINA #TSM-250PA05.18(1) POWER-ONE #AURORA PVI-3600	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5355	14041-10000-16586	3370 N VERDUGO ROAD	90065	1	153A215   220	5460008029	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.11318	-118.23534	PLAN CHECK FOR ENERGY ONLY FOR MUSIC STUDIO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5356	10041-20000-20048	8600 W PICO BLVD	90035	5	129B173    65	4303019006	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Expired	02/27/2023 12:00:00 AM	ADDRESS	34.05361	-118.37866	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5357	15041-20001-43179	19111 W ARMINTA ST	91335	3	189B121   310	2104006033	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			PC Approved	01/08/2016 12:00:00 AM	ADDRESS	34.21392	-118.54963	Fee expedite per applicantPV1, rooftop solar installation(68) Q Cells G4-260(68) Enpahse M215-60-2LL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5358	19041-10000-11746	11150 W SANTA MONICA BLVD 14TH FLR	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLAN CHECK FOR TITLE 24 ONLY INTERIOR RENOVATION OF EXISTING RESTROOMS TOTAL EFFECTED AREA 607 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5359	18041-10000-27214	6748 N LANKERSHIM BLVD	91606	2	180B169    82	2320012003	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1232.05	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.19353	-118.38758	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5360	15041-20001-09456	10808 N SUNNY BRAE AVE	91311	12	207B109   141	2707006007	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM			PC Approved	04/07/2015 12:00:00 AM	ADDRESS	34.26663	-118.58037	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (42) modules, and (1) 100-amp load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5361	13041-10001-27139	20314 W VIA MANTUA	91326	12	219B113   238	2701059030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.29836	-118.57602	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 6.25 kW. TRANSFORMERLESS INVERTER. 2 STORY.(25) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-5000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5362	11041-20000-02085	4211 N EAGLE ROCK BLVD	90065	14	156A219   107	5473024024	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.00	Electrical	Electrical	Commercial			02/02/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.12229	-118.22486	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5363	17041-20000-30352	11400 W OLYMPIC BLVD Suite 640	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.03666	-118.44346	Plan check for Title 24 only. Project site is an existing suite within a commercial building. Project scope is a tenant improvement. Total lighting area = 1,139 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5364	17041-20001-41997	1501 N SUMMITRIDGE DR	90210	5	147B157   193	4355005039	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	34.09868	-118.41997	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 38.9 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5365	19041-20000-15948	12833 W VENTURA BLVD	91604	2	165B161   920	2375021022	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	07/07/2022 12:00:00 AM	ADDRESS	34.14508	-118.41248	PLAN CHECK FOR NEW (6) PANELS OVER 1200A, (3) PANELS 601-1200A, (4) PANELS OVER 201-600A, (1) PANEL 0-200A, (43) BRANCH CIRCUITS, (4) EQUIPMENTS OVER 100 HP-KVA, (14) EQUIPMENTS 20.1-50 HP-KVA, (43) EQUIPMENTS 5.1-20 HP-KVA, (1) EQUIPMENT 3.1-5 HP-KVA, AND T24 INCLUDED, TOTAL SQUARE FOOTAGE = 181425 SF2 SEPERATE PERMITSTHIS ONE IS FROM B#18010-10000-029922ND PERMIT IS UNDERE#19041-20000-15977AND IS FROM B#18010-10000-04804	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5366	18041-20000-17275	1325-1329 E PALMETTO ST	90013	14	126A217    34	5164003018	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.04045	-118.23165	Plan check for power and energy. Project site is an existing commercial building. Project scope is a conversion from office space to (4) different tenant spaces/tenant improvement. Work includes a new 800 Amp service and a total lighting area of 33,275 sq. ft.Note: Building application has been generated under 17016-20000-30224	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5367	18041-20001-22471	9843-9853 N MASON AVE Bldg 5	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.24903	-118.58076	Revision to approved plans.  (2) additional subpanels and tree receptacle/luminaire power branch circuit connections.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5368	18041-10000-40026	8529 N WILLIS AVE	91402	6	192B149   119	2653015039	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Issued	10/19/2018 12:00:00 AM	ADDRESS	34.22559	-118.45555	PLAN CHECK FOR TITLE 24 ONLY FOR FOR REMOVA, OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5369	16041-10000-00364	2837 W SUNSET BLVD	90026	13	141A205    17	5402001037	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.08248	-118.27242	TI install new lighting and new receptacles using existing branch circuits. Install 2 new restrooms. All electrical equipments are existing. PC for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5370	19041-10000-09007	10867 W FRUITLAND DR	91604	2	162B173   746	2378004016	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1438.00	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	08/05/2022 12:00:00 AM		Permit Finaled	05/08/2024 12:00:00 AM	ADDRESS	34.13849	-118.36779	NEW 5-story 19-unit Apartment buildingwith 4 story type III-A over type IA  subterranean basement garage with a 1200 AMP  service,BUILDING PERMIT: 18010-10000-02800	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5371	13041-20000-24116	23031 W SYLVAN ST	91367	3	177B097    93	2039011003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.18476	-118.62891	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 24 MODULES. 3 STRINGS. ON 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5372	16041-20000-44252	8475 N SUNLAND BLVD	91352	6	192B177   243	2408014029	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.22451	-118.36586	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,900 sq. ft.Note: Building permit has been issued under 16016-10000-10532	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5373	16041-20000-03353	11529 N COLLETT AVE	91344	12	213B141    99	2605020026	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.28015	-118.48444	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5374	15041-20000-20075	17046 W COTTER PL	91436	5	162B133    91	2292010029	A2-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Expired	08/08/2017 12:00:00 AM	ADDRESS	34.14293	-118.50458	Installation of new roof mounted solar PV array.  Total system size = 16.4 kWac.  Two inverter system.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5375	15041-20000-18715	6226 N SHIRLEY AVE	91335	3	177B117   291	2131019012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.18366	-118.55709	Installation of new roof mounted solar PV array.  Total system size = 5.5 kWac.  Microinverter system with two branch circuits.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5376	11041-20000-11194	11976 W VENTURA BLVD	91604	2	162B165   132	2369015016	(Q)C2-1VL, (Q)P-1VL, C2-1VL, P-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	ADDRESS	34.14341	-118.39292	ENERGY PLAN CHECK ADDITION TO TRADER JOES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5377	17041-20000-23038	22100 W LONDELIUS ST	91304	12	195B101   298	2010010007	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.229	-118.6083	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.55 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5378	12041-10000-28955	6303 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM			PC Approved	12/03/2012 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI TO EXISTING OFFICE. 11TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5379	13041-10000-30098	18803 W MAPLEWOOD LANE	91326	12	207B121   786	2728031078	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.26044	-118.54324	PV1, Install 5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 20 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5380	14041-10000-01577	10723 W LE CONTE AVE	90024	5	135B153   423	4360008017	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.06407	-118.43872	PV1, Install 5 kW DC roof-mounted solar array for a two story house, interconnect with exsisting service panel. (1) Transformerless inverter(s): Solaredge SE5000A-US. (20) Modules TRINA SOLAR TSM-250PA05.18.(20) Optimizer:SOLAREDGE OP250-LV-AH4SM-2NA-Z.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5381	14041-20000-00120	4550 W PICO BLVD 1C-302	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM			PC Approved	01/09/2014 12:00:00 AM	ADDRESS	34.04842	-118.33486	T24 FOR EXISTING RESTAURANT. OCCUPANT LOAD DOES NOT EXCEED 99.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5382	13041-20001-13664	7300 W HOLLYWOOD BLVD	90046	4	147B181   182	5550016024	[Q]R5-1	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.10144	-118.34913	Modification to previously approved set of plans.  Service, pull section, and main only.  No distribution, distribution is on a future application.     <<<<<<NEW 1200A SERVICE. PC FOR NEW SERVICE ONLY. FUTURE EXPANSION NOT IN CONTRACT.  FUTURE TENANTS WILL REQUIRE FULL PLAN CHECK>>>>.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5383	12041-20000-06167	1000 E OLYMPIC BLVD	90023	9	124-5A213 437	5132004028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	12/26/2012 12:00:00 AM	PIN	34.03411878	-118.24729442	NEW 2-STORY TILT UP CONCRETE WAREHOUSE WITH ACCESSORY OFFICES USE.  TWO SEPARATE TENANTS IN ONE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5384	16041-20001-29790	1751 S MALCOLM AVE	90024	5	129B153   378	4325023017	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			06/19/2019 12:00:00 AM			PC Approved	06/19/2019 12:00:00 AM	ADDRESS	34.05084	-118.43544	Revision to approved set of plans.  Change of pull section and service/meter locations.  (((New apartment building 1200 amp service for (2) buildings connected by common roof.  plan check for power and energy.Building application numbers under 16010-20000-02308/09)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5385	17041-10000-39218	16311 W STAGG ST	91406	6	189B137    59	2205004032	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.21308	-118.48756	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5386	14041-20000-24479	6165 E HILLANDALE DR	90042	14	157-5A231 139	5483018032	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.1266	-118.18421	PV1.  Install 5.50 kW roof-mounted, utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5387	19041-20001-36648	5249 E REMSTOY DR	90032	14	147A237   155	5309009044	R1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	34.0974	-118.16554	Revisions to approved plans - change of equipment locations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5388	19041-20000-11652	7040 N WOODMAN AVE	91405	2	183B157   343	2328033043	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			04/01/2019 12:00:00 AM	09/08/2020 12:00:00 AM		Permit Finaled	08/17/2022 12:00:00 AM	ADDRESS	34.19877	-118.43106	Plan check for power and energy for  1000A 208Y/120V 3ph-4w service, 22 panels, 800A distribuiton for residential and 400A distribution for common area. Building permit filed under 18010-20000-02922.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5389	16041-10000-01066	4117 N CAMINO REAL	90065	1	147A221   127	5465025017	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.09746	-118.21489	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. MAIN BREAKER IS BEING DERATED TO 150 AMP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5390	12041-10000-05757	6075 N RESEDA BLVD	91335	3	177B125   669	2127018001	M1-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			PC Approved	03/13/2012 12:00:00 AM	PIN	34.18055005	-118.53627686	T.I. to an existing Restaurant.  New lighting, receptacles, loads.  PLAN CHECK ONLY for Energy. NO Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5391	11041-20000-18268	16830 W VENTURA BLVD 120,130	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	34.15886	-118.50032	Office t.i.Energy, emergencyFire/ Life safety by others 11041-2000017628exist. permit 11041-90000-17674	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5392	17041-20002-39072	5441 N TOPANGA CANYON BLVD	91367	3	174B101   445	2169025097	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	34.16977	-118.60612	2/26/2018Changes to an approved set of plans.  changes noted delta 3.  Changes to revise the lighting layout and the energy calculations.  no new equipment, this is plan check only.  (((Plan check for office and retail TI for Tiltle 24 energy only.  Scope includes new light, recepticals and circuits. Total effected area 3744 sq-ftB# 17016-20000-24359)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5393	18041-20002-44200	2227 N OUTPOST DR	90068	4	153B181   319	5572008012	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.11277	-118.34479	12-19-2018 Changes to an permitted set of plan, changes include update manufactuer to Hanwha Q-Cells and update System size to 19.215KW DC,  Changes has been clouded. $0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5394	15041-10000-11707	10888 W LA TUNA CANYON ROAD Ste H	91352	6	195B173    58	2408005038	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.23418	-118.3683	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5395	14041-20000-05808	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.06338	-118.20434	T24 FOR EXISTING COMPUTER LAB AT USC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5396	19041-20001-48119	2394 N BROOKSHIRE LANE	90077	5	153B141   196	4377047020	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.11356	-118.47721	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, REMOVAL OF 2 AC DISCONNECTS AND RELOCATION OF EQUIPMENTS. ALL CHANGES HAS BEEN CLOUDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5397	19041-20000-45859	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.23162	-118.58832	Replacement of (2) 1000 kVA substations with (1) 1000 kVA substation and reconnection of existing loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5398	15041-10000-21892	152 N CENTRAL AVE	90012	14	130-5A215 384	5161012904	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.05002	-118.23882	TI to (E) commercial theater space in an (E) museum.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5399	19041-10000-49368	1314 N CORONADO ST	90026	13	141A205   113	5424021005	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	12/28/2019 12:00:00 AM	ADDRESS	34.0816	-118.26736	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.38KWdc / 3.60KWac.(12)MODULES- LG ELECTRONIC LG365Q1C-V5(1)INVERTER-NINGBO GINLONG SOLIS-1P3.6-4G-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5400	17041-20000-15552	6420 W WILSHIRE BLVD 1500	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.06365	-118.36922	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighing only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5401	17041-10000-24681	1500 N EL CENTRO AVE 5th Floor	90028	13	148-5A189 331	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.09917	-118.32359	PC FOR T24 ENERGY ONLY. OFFICE TI. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5402	15041-20000-13858	7919 W MCGROARTY ST	91040	7	204B193  1335	2559025006	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.25229	-118.30548	Installation of new roof mounted solar PV array.  Total system size = 5.25 kWac.  Microinverter system with two branch circuits.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5403	12041-10000-13746	2049 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.0396	-118.44308	First time tenant, restaraunt.  New 200A panel, lighting, circuits.  Full Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5404	16041-10000-11990	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.17705	-118.6144	New F.A. installation inside a recreation center.  (1) F.A. panel    (1) Comm. Panel     (85) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5405	17041-30000-35871	11133 S AVIATION BLVD	90045	11	087B173    67	4129037914	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Closed	08/14/2018 12:00:00 AM	ADDRESS	33.93246	-118.37734	Plan check for power only for temp power for construction site for LAX Runway. 600A 480/277V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5406	16041-10000-33506	2327 W 37TH ST	90732	15	009B185    10	7563031011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	33.72338	-118.32705	Installation of new roof mounted solar pv array on existing single family dwelling.  Interconnect with existing 2.5 kWac system.  New SolarEdge SE3800A-US inverter with 20 new Trina Solar TSM-255 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5407	14041-20000-27165	22720 W VOSE ST	91307	12	183B097   438	2024021042	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.19773	-118.62183	PV STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5408	14041-10000-03385	5507 W HOLLYWOOD BLVD	90028	13	148-5A193 129	5544005024	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.10192	-118.30983	Full plan check for power and energy. Marshal retail store.Area 23797 sq ft.,  sareh caculated to  27831.81,  medi recounted and new fees 3142.37 .  applicant Mr. clyde Wood unable to pay full plan check fee at this time  so in addition to final fees please add 30   480/277  lighting ckts at final.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5409	16041-20000-07482	20657 W CANTLAY ST	91306	3	186B109   980	2113017005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.20236	-118.58384	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5410	18041-10000-32765	810 N EVERGREEN AVE	90033	14	129A227   208	5178008006	C1-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.0477	-118.19761	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5411	16041-10000-34648	10250 W SANTA MONICA BLVD #1570	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for a first time tenant space at westfield mall ""Zadig"". Adding a new panel and a tranformer under existing service. New lighting and power. Total sqft = 2243*New load 46A to MS-ELA42Fire alarm system and low voltage are not subject to this plan check."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5412	19041-20000-48267	4221 S REDWOOD AVE	90066	11	108B153  1209	4230006025	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	03/10/2021 12:00:00 AM	ADDRESS	33.98894	-118.43857	PROVIDE NEW 800A 120/240V SERVICE RECONNECTING EXISTING DISTRIBUTION SWITCHBOARD WITH NEW FEEDERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5413	16041-10000-23949	2633 S HOOVER ST	90007	9	123A201   161	5055024010	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.03071	-118.28433	pv1, install new 7.9 kw ac roof-mounted solar aray on a single family house.(33) modules; lg315n1c-g4 lg neon 2(33) microinverters: enphase m250-60-2ll-s22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5414	12041-10000-28419	12237 W DOROTHY ST	90049	11	129B141   503	4264012022	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.04703	-118.47302	INSTALL ON ROOF OF SFD A  9.56KW PHOTOVOLTAIC SYATEM USING M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5415	19041-20000-30795	19401 W ENADIA WAY	91335	3	183B117   121	2130026022	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.20027	-118.55579	PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.88KW DC/4.101 KW AC. SCOPE OF WORK INCLUDES (16) PV MODULES WITH POWER OPTIMIZERS AND A INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5416	17041-10001-42235	20808 W HORACE ST	91311	12	207B109    89	2706009014	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.26701	-118.5868	Expedite per applicant request(((PV1  13kw roof mounted system with (45) modules and  Enphase microinverter connecting through a 100Amp sub panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5417	16041-10000-37993	353 S BROADWAY 201/501	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.04991	-118.24934	Plan check for Title 24 only in existing space T.I. in high-rise Building for Suite 201/501. Total area: 4,000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5418	16041-10000-31986	629 1/2 W 85TH ST	90044	8	097-5A201 156	6032018051	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Issued	09/12/2016 12:00:00 AM	ADDRESS	33.96122	-118.28493	PV1. NEW SOLAR SYSTEM FOR AN EXISTING COMMERCIAL ROOF-TOP (multi dwelling residential). TOTAL SYSTEM SIZE IS 3.0KWac.(8)MODULES-KYOCERA#KU2656ZPA(1)INVERTER-ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5419	10041-10000-09847	607 S HILL ST	90014	9	129A211   123	5144003045	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Expired	11/27/2012 12:00:00 AM	ADDRESS	34.04721	-118.25346	Existing service, replacing all existing equipment with more efficient system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5420	17041-10000-02873	7652 N TEXHOMA AVE	91325	12	186B129    67	2202003008	RA-1, RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.21006	-118.51523	"PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL GARAGE ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(6)MODULES-PANASONIC VBHN325SA16(6)OPTIMIZERS-SOLAREDEGE P400(1)INVERTER-3.0KW SE3000H-USNote: Permit for PV system for meter ""A"" is under PCIS#17041-10000-02877"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5421	19041-20001-24170	6038 N JUMILLA AVE	91367	3	177B117   572	2153021013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.18041	-118.56352	Revision to approved set of plans.  Equipment location changes and associated distribution changes. (((PLAN CHECK FOR INSTALLATION OF A 27 KWH ENERGY STORAGE SYSTEM ON EXISTING SFD WITH EXISTING PV. SCOPE OF WORK INCLUDES (2) 13.5KWH TESLA POWER WALLS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5422	16041-10001-16576	6150 W 96TH ST	90045	11	093B165   121	4124027906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	33.94871	-118.39284	PC for changes to approved set under delta 2 Changes includes a 600A panel like for like per inspector.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5423	16041-20000-31810	2752 W DELOR ROAD	90065	14	159A219   143	5684018020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.13079	-118.2273	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5424	16041-20000-10444	9201 W VENICE BLVD	90034	5	120B165   446	4313021084	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.02665	-118.39362	PLANCHECK FOR POWER AND ENERGY. Tenant improvement for dental office.Note: Building permit has been issued under 15016-30000-28355.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5425	16041-10000-36037	7463 N CRANER AVE	91352	2	186B173   515	2410001025	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.20657	-118.36934	NEW ROOF MOUNTED SOLAR SYSTEM (10) SOLAR PANELS AND (1) 5KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5426	16041-10000-31245	1210 W 68TH ST	90044	8	102B197   532	6014023013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	33.97772	-118.29625	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.01 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5427	19041-20000-05952	3951 N EAGLE ROCK BLVD	90065	13	156A217   204	5460001018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.12014	-118.22935	NEW ROOFTOP SOLAR SYSTEM FOR EXISTING MOTEL. SYSTEM SIZE IS 11.4 KW AC, SCOPE OF WORK INCLUDES (39) LG360 PV MODULES, (39) SEP370 OPTIMIZERS, AND (1) SE11400H INVERTER.PERMIT IS FOR 1 OF 2 PV SYSTEMS, TWO BUILDINGS ON ONE PROPERTY.SECOND SYSTEM UNDER PERMIT#19041-20000-05947	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5428	16041-30001-40632	12101 W VENICE BLVD	90066	11	114B157  1294	4248030025	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM			PC Approved	01/05/2017 12:00:00 AM	ADDRESS	34.00565	-118.4304	Title 24 plan check.  T.I. to existing single story retail building.  Total area = 6,729 sq. ft.  Total new connected load less than 400 amps.  Plugs permitted under master permit 16041-20000-40632.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5429	18041-10000-03059	8363 N RESEDA BLVD	91324	12	192B125   489	2785018004	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.22256	-118.53629	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5430	11041-20000-14119	127 S SAN VICENTE BLVD Bulletin-42	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	07/28/2011 12:00:00 AM		Permit Closed	02/15/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin # 42.  New branch ckts added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5431	13041-20001-25350	9221 N ARLETA AVE	91331	6	198B157   732	2625010002	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	ADDRESS	34.23746	-118.42148	PC FOR T24 ENERGY ONLY. SENIOR REHAB CENTER. NON MEDICAL. TOTAL AREA 1353 SQ FT. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5432	16041-20000-24977	16633 W VENTURA BLVD STE 804	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	TI TO AN EXISTING COMMERCIAL BUIILDING HIGH RISE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 740 IN SUITE 804.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5433	17041-20000-22773	8100 N WHITSETT AVE	91605	2	189B165   155	2308017012	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Issued	07/07/2017 12:00:00 AM	ADDRESS	34.2178	-118.40508	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5434	18041-10000-23457	1646 N NORTH SPRING ST C	90012	1	136-5A217  47	5409002030	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.06924	-118.22761	PLAN CHECK FOR T24 ONLY, TI  ON LONGE OF THE  (E) MANUFACTURING. TOTAL AREA: 1105 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5435	15041-20000-20901	16545 W LASSEN ST	91343	12	201B137   139	2678026001	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.25035	-118.49297	Plan check PV tri-plex unit system. System size: 3.0kW. Each unit is rated to 200A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5436	10041-10000-17696	225 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			Corrections Issued	09/19/2010 12:00:00 AM	ADDRESS	34.04942	-118.22625	Solar voltaic system installed on the roof of the building.  Consists of  13 modules, 13 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5437	11041-10001-09948	879 W 190TH ST 4TH FL	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM			PC Approved	09/14/2011 12:00:00 AM	ADDRESS	33.85951	-118.28963	Revisions to previously approved plans to show modification of  installed luminaires, see delta 1.  T-24 lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5438	13041-20000-07062	17221 W SUNBURST ST	91325	12	195B133    27	2690001004	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2013 12:00:00 AM			Reviewed by Supervisor	04/09/2013 12:00:00 AM	ADDRESS	34.23462	-118.50944	New transformerless photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5439	11041-20000-24596	3944 N MANDEVILLE CANYON ROAD	90049	11	156B133    71	4490015001	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2011 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Finaled	03/13/2012 12:00:00 AM	ADDRESS	34.12294	-118.50684	New 7.755 KW roof mounted PV system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5440	15041-20000-18308	14006 W RIVERSIDE DR #115	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only for Shoe store The Walking Company. Total area: 1,368 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5441	16041-20000-06429	16344 W HORACE ST	91344	12	210B137   677	2680019036	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM			Reviewed by Supervisor	03/08/2016 12:00:00 AM	ADDRESS	34.27003	-118.4884	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (32) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5442	19041-20001-06622	10001 W VENICE BLVD	90034	5	120B165  1150	4313006041	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	34.02296	-118.40001	expeditepv3install roof mounted pv system sized 120KW AC interconnected with msp.  (350) adani solar 360Watt modules(4) solaredge 30KW inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5443	14041-20001-05271	11361 N RUGGIERO AVE	91342	7	210B173    22	2529020004	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.27629	-118.36698	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5444	17041-20000-43424	4345 S CRENSHAW BLVD	90008	8	111B185    46	5024006012	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.00419	-118.33292	Plan check for power only. Upgrading service for existing commercial building to 800A 120/240V 3ph 4w. Existing loads to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5445	11041-20000-23725	3434 S GRAND AVE	90007	9	118-5A203 116	5122030020	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.01912	-118.27658	T24 Energy plan check first floor for at USC Licensing Area. Permit for new panels, ckts, equipment, and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5446	14041-10000-25498	3922 N SUNNY OAK ROAD	91403	4	163-5A147 230	2277031018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.14131	-118.4593	Installation of new roof mounted solar PV system. Total system size = 3.8 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5447	16041-20001-13185	20634 W CLARENDON ST	91367	3	174B109   560	2151030054	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM			PC Approved	05/02/2016 12:00:00 AM	ADDRESS	34.17096	-118.58263	Expedited per applicant request.Plan check for an addition of a PV1 roof-mounted 3.6 kWac PV system onto an existing system. PV addition consists of (1) inverter, (17) modules, (1) combiner box, and (1) load center. Total system size is 8.6 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5448	14041-10000-34361	124 E 11TH ST	90015	14	126A209   220	5139016026	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.03856	-118.25765	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL 748 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5449	19041-30000-37175	350 S GRAND AVE 31st and-37th floor	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	07/02/2020 12:00:00 AM	ADDRESS	34.05173	-118.2522	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO THE 31ST FLOOR - 175 SF AND 37TH FLOOR- FULL FLOOR 24,140SF, INTERIOR OFFICE T.I. TOTAL SQ. FT. 24315.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5450	17041-20000-26114	19931 W MID PINES LANE	91326	12	213B113    17	2701034014	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.28413	-118.57005	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (2) inverters, (47) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5451	15041-10000-11200	1945 W BLAKE AVE	90039	13	148-5A213 317	5442010028	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.09967	-118.24376	RETROFIT OF 22 EXISTING LIGHTS TO LED WITH RETROFITS KITS. TITLE 24,  PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5452	15041-10000-40734	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.04538	-118.26389	FULL PC, TI TO AN (E) HIGH RISE  HOTEL BUILDING WITH 288 UNIT APARTMENT. SCOPE OF WORK INCLUDES THE REPLACEMENT OF ALL ELECTRICAL EQUIPMENT WITH EXISTING 2000AMP SERVICE. TOTAL SQ. FT. 57,334.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5453	15041-20000-19279	15215 W FRED WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.20917	-118.46476	Plan check for PV roof mounted system. System size: 3.6kW with 18 modules and 1 invetere(3.6kW). Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5454	10041-10000-10058	1902 W PARK AVE	90026	13, 14	139-5A207 209	5404002009	R3-1VL-CDO	Central, East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20, 1975.00	Electrical	Electrical	Apartment			05/27/2010 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.07616	-118.26168	THREE STORY TYPE-VA APARTMENTS OVER ONE STORY TYPE -1A SUBTERRANEAN PARKINGNOTE THAT VARIANCE TO SEPARATE THE FA PLANS IS REQUIRED AND PLAN CHK FEE NEEDS TO BE INCREASED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5455	13041-10000-27759	20163 W VIA MEDICI	91326	12	219B113    53	2701041018	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.29453	-118.57286	PV1 6KWdc. 240V. negative GND. STD. 1story. Roofmount. [(1) inverters: {Fronius IG 5100}]. [(24)modules: {Trina {TSM-250PA05.08}}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5456	11041-10000-12864	5125 S MAIN ST 1-46	90037	9	111A203   432	5110025032	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Public Safety Only			06/21/2011 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	33.99607	-118.27429	FIRE WARNING SYSTEMIN A 4-STORIES SENIOR APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5457	10041-10000-06662	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	C2-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	07/23/2010 12:00:00 AM	ADDRESS	34.04338	-118.26581	"Plan check T-24 Energy lighting for Hyde Club pantry (Suite level ""C"") at Staples Center"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5458	12041-20000-06442	4209 W CLAYTON AVE	90027	4	148-5A201 238	5430003034	R1-1	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	07/02/2012 12:00:00 AM	ADDRESS	34.1001	-118.28233	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM, SFD, 5.92 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5459	17041-10001-35147	8202 W MELROSE AVE	90046	5	141B173   467	5528012033	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Info Complete	03/29/2018 12:00:00 AM	ADDRESS	34.08352	-118.36822	PC FOR CHANGES TO APPROVED SET. CHANGES MARKED UNDER DELTA 2. SCOPE INCLUDES ADDITION OF ACCENT LIGHTS IN RETAIL SPACE ON TWO NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5460	18041-20002-37699	17829 W PALORA ST	91316	5	168B129   143	2182006012	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.15972	-118.52103	Revisions to approved set.  Wiring configuration changed to backup of entire 200A main disconnect section of 2x200A service panel.(((Plan check for energy storage system installed in to existing PV system, Energy storage system size: 40.5kWh, 3 Tesla Powerwall 13.5kWh.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5461	17041-20000-03129	22950 W VANOWEN ST ste d	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.19343	-118.62746	ti to an existing commercial space.  adding new lighting new control to restroom only. newly connected load <400amps, plan check for energy only.  total square footage 58.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5462	17041-10000-26087	721 E BROOKS AVE	90291	11	111B145  1266	4239007006	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	33.9972	-118.46561	PLAN CHECK FOR BATTERY BACK UP SYSTEM WITH PV SYSTEM - SYSTEM CONSIST OF 2 TESLA POWER WALLS (14KVA).  PV SYSTEM PCIS #17041-10000-26084PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE (3.6KVA) WITH BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF 1 INVERTER (ABB PVI 3.6) WITH 15 MODULES (SOLARCITY).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5463	12041-10000-19390	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM			Reviewed by Supervisor	08/27/2012 12:00:00 AM	ADDRESS	34.01366	-118.28294	Los Angeles Memorial Colliseum, Place of Assembly.  New 75kva transformer, new sub panel and loads.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5464	12041-10000-29875	10500 W KLING ST	91602	4	168B177   734	2420032006	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.15572	-118.35931	PV1.  New 14.388 KW roof mounted PV system for a single family residence.  Installing 44 modules, 2 ombiner boxes, 2 inverters, and 1 sub panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5465	14041-20000-23242	21025 W ARMINTA ST	91304	3	189B105   325	2109014025	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.21369	-118.59171	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW.(1) ABB PVI-5000-OUTD-US-A transformerless inverter(23) Trina Solar TSM-250 PA05.05 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5466	16041-20000-18014	9117 S LA SALLE AVE	90047	8	094-5A195 106	6037006025	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	33.95402	-118.30587	PV1.  Install 3.36 KW roof mounted PV system.  (12) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5467	15041-20003-37580	6400 N LAUREL CANYON BLVD Suite 600	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM			PC Approved	07/12/2016 12:00:00 AM	ADDRESS	34.18693	-118.3963	07-12-2016 Changes to an approved set of plan. Changes include panel schedule revised and home-run circuit revised. Changes apply to delta 3 only***********Previous Work Description**************************Revisions to approved set.  Lighting design changes, slight modifications to architectural layout.  (((Plan check for Title 24 only. Project site a suite within an existing commercial high-rise building (6th floor, Suite 600). Project scope is a tenant improvement. Total lighting area = 6,606 sq. ft.Note:  Building application has been filed under 15016-20000-20273)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5468	19041-20000-00935	516 N FRIES AVE	90744	15	030B205   985	7418004014	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Apartment			01/09/2019 12:00:00 AM			Reviewed by Supervisor	01/29/2019 12:00:00 AM	ADDRESS	33.77618	-118.26457	Plan check for power and energy for affordable housing low income 18 uits 2 story multi-family building, 800A 240/120Volt Service. Total common area: 7734 sq ft. B#18010-30000-01385	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5469	17041-10000-04640	20200 W RINALDI ST S5	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.27515	-118.57076	PC FOR POWER AND ENERGY. NEW BUILDING S5 - SHELL ONLY COMMERCIAL BUILDING, 1 STORY, SERVICE 600A 277/480 V, TOTAL AREA 2548 SQ FT.B# 16010-10000-06145	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5470	12041-20001-09509	5240 N LANKERSHIM BLVD #101	91601		171B173  1387	2350018086							Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM			PC Approved	11/16/2012 12:00:00 AM	ADDRESS	34.16613	-118.3751	Delta 9 cheanges to previously approved set of plans.  Existing permit.  Change space from dinning to new storage room.  Modify the lighting system.  No additional circuits added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5471	18041-10000-19781	222 W 6TH ST 1-10	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM			PC Info Complete	01/15/2019 12:00:00 AM	ADDRESS	33.73887	-118.28305	***Plan Check ONLY - Permit #  19041-40000-18892 - Subject to Field Inspection to verify the permitted items***PC FOR RESTAURANT TI   FOR FIRST TIME TENANT RESTAURANT. SCOPE INCLUDES NEW LIGHTS EQUIPMET AND RECEPTACLES. TOTAL AFFECTED AREA 2637 SQ. FT. B# 18016-10000-16852	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5472	16041-10000-42696	7514 N RESEDA BLVD	91335	3	186B125   378	2119017041	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.20698	-118.53586	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total sqft = 101,050	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5473	12041-10000-06274	1504 W PALOS VERDES DR NORTH BLDG B	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77938	-118.30382	Plan check 164.97KW roof mounted photovoltaic system for charter school building. Building B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5474	13041-10000-03839	6756 W FRANKLIN PL	90028	13	150A185   323	5547002008	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.10403	-118.33805	"CHANGE OF USE FROM ELEMENTARY SCHOOL TO BEAUTY SALON/RETAIL. no emergency lighting and less than 400A per applicant. NO CHANGE IN PARKING. ""COMPLTY WITH DEPARTMENT ODER effective date 04/09/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5475	17041-10002-21826	227 S GAREY ST	90012	14	129A215   251	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.04634	-118.23533	REVISED SINGLE LINE TO SHOW THE REMOVAL OF THE FUSED DISCONNECT SWITCH ON THE SECONDARY TAP AS THE TAP LENGTH IS LESS THAN 5ft AND MEETS Section 240.21(C)(2) OF THE NEC(((((Plan check for power and Title 24.  Renovation of existing restaurant space.  New 350 kVA transformer and 800 amp distribution board with 5 subpanels feeding new lighting, receptacles, and HVAC.  Lighting area = 4,123 sq. ft. (indoor) + 1,042 sq. ft. (outdoor)     Building permit #17014-10000-03010	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5476	12041-10000-24206	4151 W PROSPECT AVE Bldg  F	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.10191	-118.28217	disconnecting the generator as a back-up source to optional stand-by loads and replace it with an existing 50kva  ups; new feeders; add a panel to asupply cu and fcu units	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5477	14041-10000-00979	21618 W LOS ALIMOS ST	91311	12	207B105   217	2722030003	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.26508	-118.6007	PV1, Install 5 kW DC roof-mounted solar array, interconnect with existing service panel. (1)regular  Inverter: KACO 50002xi. (20) modules Canadian Solar CS6P-250P.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5478	16041-10000-35488	4078 N DEERVALE DR	91403	4	162B149   161	2275008015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.14375	-118.45052	PV 1 roof mounted solar system installation to a single family home. Installing 28 Microinverters rated at 250 Watts each for a total system size of  7.00KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5479	19041-20000-23014	1217 S ALVARADO ST	90006	1	129A201   123	5136024005	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Apartment			06/17/2019 12:00:00 AM			PC Info Complete	06/17/2019 12:00:00 AM	ADDRESS	34.04833	-118.28223	New emergency egress lighting for (E) 2-story apartment building.  90 minute integral battery backup throughout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5480	17041-10001-11784	6222 W WILSHIRE BLVD #500	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.06309	-118.36418	CHANGES TO APPROVED SET OF PLAN - CHANGES INCLUDE UPDATED SINGLE LINE DIAGRAM TO INCLUDE EXISTING LOADS, AND ADDITION OF NOEW LIGHTING ORIGINAL PLAN CHECK #17041-10000-11784PC FOR ENERGY. T.I OFFICE. CONNECTED LOAD <400A. AFFECTED AREA 776 SQ FT. B# 17014-10000-00272	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5481	19041-10000-34587	1746 S CRESCENT HEIGHTS BLVD	90035	10	126B173    72	5066008013	R1R3-RG	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.04536	-118.37395	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 7.92 kW DC (6.732 kW AC) PV SYSTEM CONSISTING OF 24 PANASONIC 330W MODULES WITH P400 POWER OPTIMIZERS, SOLAREDGE 7.6 kW HD WAVE INVERTER CONNECTED TO EXISTING 200A PANELPANEL UPGRADE OR RELOCATION TO BE DONE SEPARATELY	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5482	11041-20000-19914	10700 S PERSHING DR	90045	11	087B157     1	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2780.00	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	33.93748	-118.43218	New lay down area for construction vehicles and material.  Plan check is for energy only.Permit include 2 panels and 20 cardreaders & cameras	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5483	18041-20000-10651	14810 W DELANO ST	91411	6	178-5A149 253	2241017004	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			03/23/2018 12:00:00 AM	02/14/2023 12:00:00 AM		Issued	02/14/2023 12:00:00 AM	ADDRESS	34.18241	-118.45587	Plan check for power and energy. Project site is a new 4-story, 18-unit apartment building. Work includes an 800-amp service and a total lighting area of 18,717 sq. ft.Note: Building application has been generated under 17010-20000-04890	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5484	16041-10000-21070	5915 W FRANKLIN AVE	90068	4	150A191   170	5586014054	C1-1D	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.1054	-118.31886	ICE CREAM SHOP, NEW LIGHTING. PC FOR T24 ENERGY ONLY. - refer to supplemental for new plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5485	16041-10000-28441	520 S SAN JULIAN ST	90013	14	127-5A213 258	5148012016	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.04388	-118.24528	FULL PC FOR POWER AND ENERGY FOR AN EXISTING AFFORDABLE HOUSING(113 UNITS) BUILDING. SCOPE INCLUDES REPLACING THE EXISTING SERVICE EQUIIPMENT WITH A NEW 2000A 120/240V 3PHASE 4WIRE SERVICE/DISTRIBUTION BOARD AND ADDING 11 NEW SUBPANELS. NEW SERVICE IS FEEDING NEW AND EXISTING PANELS. TOTAL AFFECTED AREA IS 17416 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5486	18041-20000-15622	7518 N LINDLEY AVE	91335	3	186B125   374	2120019009	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.20716	-118.52716	Plan check for PV roof mounted system. System size: 5.4kWac with 15 AC Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5487	16041-10000-43104	14344 W ROSCOE BLVD	91402	6	192B149   392	2212004035	C1-1L, P-1L, [Q]CR-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.22143	-118.44623	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total area:15550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5488	17041-20000-14220	9051 N WOODMAN AVE UNIT 1-18	91331	6	195B153   151	2639033013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Issued	06/14/2017 12:00:00 AM	ADDRESS	34.2341	-118.43986	PLANCHECK FOR POWER ONLY. NEW UNDERGROUND 3000AMP SERVICE AND PANELBOARDS IN EACH UNIT. UNIT 1-18 .   MSB-1  (1 OF 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5489	14041-20002-24735	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	"PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE REQUIRED CAR CHARGER EQUIPMENT REVISIONS AND ADDITION OF A FEW CIRCUITS. ALL CHANGES CLOUDED DELTA ""AS""THIS PLAN SHALL CONFORM TO 2008 BUILDING EFFICIENCY STANDARDSPERMIT FOR CAR CHARGING EQUIPMENT HAS ALREADY BEEN ISSUED UNDER PERMIT NUMBERS 15041-20000-23050 AND 15041-20001-23050. THIS APPLICATION IS FOR THE PLAN CHECK OF ALL CHANGES AND PERMIT FOR ADDITION OF 4 CIRCUITS FOR MISC. LOADS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5490	15041-20001-21697	6316 N TOPANGA CANYON BLVD B-1125	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	Changes to approved set.  Removing safety switch on transformer secondary (conductors less than 10')Plan check for power and energy. Project scope is a first time tenant at the Westfield Village project. Total lighting area = 1,639 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5491	16041-10000-31359	222 S BERNARD AVE	90291	11	111B145   649	4240001014	RD2-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.00098	-118.47143	ROOF MOUNTED PVPV SYSTEM SFD. TOTAL SYSTEM SIZE 3.8KW AC USING 17 MODULES IN TOTAL. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5492	09041-10001-24074	600 W WORLD WAY TERMINAL 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	TERMINAL 6  RENOVATIONS-  RELOCATING ALASKA AIRLINES OFFICES TO  NEW AREAS  ; REMODEL BAGGAGE HANDLING AREA  WHICH IS AWAY FROM THE PASSAGENER AREA(((    Changes made to prviously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5493	14041-20001-29254	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	3/11/2015 Changes to an approved set of plans. Changes include the change of model (same manufacturer) for (4) types of light fixtures, and change of model for the dimmer switch. Changes in the power rating are reflected on the Title 24 forms. All changes have been clouded and labeled as Delta 1.*****Previous Work Description*****TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHITNG FIXTURES TO EXISTING PANELS.  751 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5494	13041-10000-28681	7639 W DAY ST 1-3	91042	7	204A197   186	2558034033	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Apartment			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.25464	-118.29919	Fire alarm system installation. Two story apartment 48 units, plan chek and permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5495	12041-10000-20968	6174 E ALDAMA ST	90042	1	154-5A229 205	5484016004	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.20	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM	09/05/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.11769	-118.18985	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5496	16041-20000-24483	10701 W BELLAGIO ROAD	90077	5	141B149   317	4362003039	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM			PC Info Complete	11/29/2016 12:00:00 AM	ADDRESS	34.08153	-118.44866	NEW SFD. PC FOR POWER ONLY. 1200 AMP SERVICE. Plan check only Permit paid under Building permit #14010-30000-03038	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5497	14041-10000-00687	1145 S GAYLEY AVE	90024	5	132B149   118	4363023033	C4-2D-O	West Los Angeles		Westwood		2653.05	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.05935	-118.44602	Plan check for power and energy for a two story building related to UCLA . Work done on a first floor.With existing service and new one panel. Total area 17735 sq ft. Occupant load?	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5498	13041-10002-12515	819 S SANTEE ST	90014	14	126A211    46	5145013005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			01/05/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Closed	11/17/2016 12:00:00 AM	ADDRESS	34.04107	-118.25233	Pc for power. Revision to approved set of plan. change and relocating 4 disribution board for 14 floors.{	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5499	14041-10000-19724	2581 E CHAUCER ST	90065	1	147A217   364	5442002908	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM			Corrections Issued	07/22/2014 12:00:00 AM				Title 24 plan check only.  Install landscape lighting and cistern pump.  Building application submitted before title 24 part 6 effective date.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5500	14041-20000-13270	10425 N HILLVIEW AVE	91311	12	207B105   742	2722013018	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.25982	-118.60299	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 864 WATTS. USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5501	11041-10000-11617	9200 N GLENOAKS BLVD	91352	2	198B173   111	2408001003	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	08/08/2011 12:00:00 AM		Permit Finaled	09/20/2011 12:00:00 AM	ADDRESS	34.2363	-118.37296	T.I.  Existing 38,883 sqft parking lot for trash trucks.  Modifying 16 parking lights.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5502	17041-20000-46640	6020 N MELVIN AVE	91356	3	177B117   614	2153028029	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.17999	-118.55979	permit fee $0.00 by state senate bill no.1222Plan check for solar pv system w/roof-mounted solar array on SFD.11.04kW ungrounded system.(48) EnPhase IQ6-60 microinverters.(48) 300W pv modules.Derating main breaker from 200A to 175A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5503	14041-20000-33263	13467 W DESMOND ST	91331	7	213B157   710	2523017023	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.277	-118.42621	PV1Install a roof-mounted solar array on SFD. Interconnect with 100A MSP.System size: 3.44kW. Ungrounded system.16 EnPhase M215-IG microinverters with 16 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5504	17041-10000-03343	5800 W SUNSET BLVD	90028	13	147A191   150	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Issued	02/27/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	TI TO STAGE 4 AND 5. PC FOR T24 ENERGY ONLY. b#16016-70000-08284.  ELECTRICATL MAINTENANCE SUPERVISOR. JOHN AHLES LIC#P035598. SUNSET BRONSON STUDIOS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5505	17041-20001-18100	3671 N SUNSWEPT DR	91604	2	162B165   878	2376011008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2017 12:00:00 AM			PC Approved	06/23/2017 12:00:00 AM	ADDRESS	34.13845	-118.40509	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.20kW ungrounded system. (77) 340W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5506	17041-20000-03876	4418 N VINELAND AVE	91602	4	165B173   268	2423008001	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			02/07/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Issued	02/24/2017 12:00:00 AM	ADDRESS	34.15103	-118.37009	Exterior and interior lighting to apartment building common area.  Plan check for energy. 4800 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5507	15041-20000-22450	6115 W SUNSET BLVD SUITE 100	90028	13	147A189    24	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.09819	-118.32261	Plan check for power and Title-24 (energy).  Total area = 5,273 sq. ft. (indoor) + 600 sq. ft. (outdoor).  T.I. to existing restaraunt space.  Complete electrical retrofit with new 600 A distribution board.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5508	14041-20000-15136	881 E WARREN AVE	90291	11	111B145   205	4243013027	R1-1	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.00318	-118.4664	PV1Microinverter standard plan. Install roof mounted solar array on detached garage of SFD. System size: 3.024kW. (14) Enphase M215 microinverters. (14) Sun Edison F260 pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5509	10041-10000-15150	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	03/04/2011 12:00:00 AM	ADDRESS	34.14246	-118.2705	baxter lamp bldg 4 alteration and renovation. two panels and 56 fa devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5510	18041-10001-01662	1836 N COURTNEY TER	90046	4	150B177   474	5551010034	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.10415	-118.35814	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.95KWdc / 12.88KWac.(46)MODULES-LG LG325N1C-A5(46)MICROINVERTERS-ENPHASE IQ6PLUS-72-2-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5511	19041-20000-00111	14541 W GILMORE ST	91411	6	180B149   671	2236016016	[Q]CR-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			01/02/2019 12:00:00 AM	06/16/2021 12:00:00 AM		Permit Finaled	10/17/2023 12:00:00 AM	ADDRESS	34.18781	-118.45022	1200A 240/120V 3ph-4w service, distribution, and wiring for new multifamily reidential construction.  Plan check for power and energy. Total area: 23,097 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5512	14041-20000-15209	11243 N MCLENNAN AVE	91344	12	210B133   168	2682022016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.27506	-118.50121	PV1.  Install 8.8 kW roof-mounted utility-interactive PV system.  Transformerless standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5513	14041-20001-18509	13159 N BRADLEY AVE	91342	7	222B145    22	2501006029	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM			PC Approved	08/20/2014 12:00:00 AM	ADDRESS	34.30904	-118.46482	EXPEDITE PER CUSTOMR REQUEST.PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC. USING CENTRAL TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. 24 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5514	11041-10000-25391	979 S SERRANO AVE	90006	10	129B193   143	5080015012	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	09/18/2013 12:00:00 AM	ADDRESS	34.05333	-118.30653	Complete electrical system for a new 6-story, with basement, apartment building.  641 new circuits, new service, etc.  Full plan check.  Variance will be filed to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5515	13041-10001-02654	4950 N LEDGE AVE	91601	4	168B177    38	2420009021	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	34.16092	-118.35702	Supplemental description: Change of module from REC 245PE to REC 250PE.  Original description: PHOTOVOLTAIC SYSTEM FOR SINGLE STORY SINGLE FAMILY DWELLING. PV1 SYSTEM TOTAL SIZE OF 3.67KW. TOTAL OF 17 UNITS. MICROINVERTER ENPHASE M215-60-2LL-S22. PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5516	17041-20001-45167	17627 W VENTURA BLVD	91316	5	171B129   337	2257008040	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.16227	-118.51713	[[[1/3/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING THE LIGHTING LAYOUT TO SHOW EXISTING FIXTURES]]]]PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM (E) BARBER SHOP (14VN129031) TO NAIL SALON. 1377 SQFT.BUILDING P# 17016-20000-30691	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5517	12041-10000-19195	6411 N ELLENVIEW AVE	91307	3	180B085   141	2032006001	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.18615	-118.65813	Plan check for new 7.65KW roof mounted photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5518	17041-10000-03993	417 N HAWAIIAN AVE BLDG 1	90744	15	027B201   421	7417005901	[Q]RD2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.77406	-118.27658	PC for fire alarm in apartment with 40 devices and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5519	14041-10000-13826	3287 N VELMA DR	90068	4	159B181   125	5579007007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.13409	-118.34515	PV1, INSTALL 5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5520	13041-10001-09635	4975 W PICO BLVD	90019	10	129B181   960	5070002037	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/14/2013 12:00:00 AM	ADDRESS	34.04794	-118.34556	PLAN CHECK ONLY. REVISION TO APPROVED PLANS. CHANGE UPS SIZE, ADD NEW PANELS, RELOCATE CIRCUITS, AND CHANGE LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5521	17041-20000-38544	3285 S MOUNTAIN VIEW AVE	90066	11	117B153   786	4248014037	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.01573	-118.43861	Plan check for solar pv system w/roof-mounted array and DC coupled battery backup system for SFD.Total pv system size: 7.6kW.(1) 7.6kW SolarEdge inverter.(19) 290W pv modules.(19) 300W power optimizers.(1) 9.8kW DC battery bank.(1) 5kW auto-transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5522	13041-10004-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			03/14/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.10155	-118.31097	CHANGES TO AN APPROVED SET OF PLAN. CHANGES ARE UNDER DELTA 13 WHICH INCLUDE MODIFYING THE SINGLE LINE DIAGRAM, AND  FEEDER SIZES.  ADDITION OF NEW LOADS (SEE PANEL SCHEDULE AND SERVICE LOAD). CHANGES ALSO INCLUDE RELOCATION OF MAIN ELECTRICAL SWITCH BOARD AND DISTRIBUTION EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5523	16041-20000-05048	537 S BROADWAY	90013	14	129A211   120	5149033003	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.04731	-118.25166	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. New 2,000-amp electrical service and power distribution system. New fire pump and generator. Total indoor lighting area = 43,631 sq. ft. and total outdoor lighting area = 1,001 sq. ft.Note: Building application has been generated under 15016-10000-06187	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5524	13041-10000-34043	1000 W WILSHIRE BLVD	90017	9	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Expired	01/04/2016 12:00:00 AM	ADDRESS	34.05085	-118.26078	PLANCHECK AND PERMIT FOR T24 ENERGY ONLY. 1140 SQFT.BUILDING PERMIT 13016-10000-23327Tenant Improvement to set up two mock-up rooms (one guestroom and one deluxe suite) of Wilshire Grand hotel within the existing office space. Work includes to add all hotel room fixtures including simulated hotel corridor but no phyical connection to MEP server, re-route fire sprinkler lines.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5525	19041-10001-12844	1700 N NAUD ST	90012	1	136-5A219 129	5409002021	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	34.06865	-118.22638	Changes to an approved set, changes include changing fixture type, all changes are under delta 2. Permit will be pulled under master application 19041-10000-12844	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5526	10041-20000-13705	15649 W ODYSSEY DR	91344	12	213B145   244	2605025***	[Q]OS-1XL, [T][Q]RD2-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1092.00	Electrical	Electrical	Apartment			07/16/2010 12:00:00 AM			Corrections Issued	07/16/2010 12:00:00 AM	ADDRESS	34.28372	-118.47101	outdoor lighting in gated community. Energy onlyl.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5527	18041-10002-11448	1934-1936 N DRACENA DR	90027	4	150B197   696	5590013007	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.10638	-118.29	$0 FEES DUE TO SENATE BILL 1222ADDITIONAL PERMIT FOR THE NEWLY SIZED INVERTER RATED AT 7.6KW(1)INVERTERS-SOLAREDGE SE7600H-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5528	14041-20001-00938	23501 W OXNARD ST	91367	3	177B093   709	2035003057	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.17891	-118.63877	EXPEDITE FEES ONLY.            <<<NEW PV SYSTEM FOR AN EXISTING SFR.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5529	13041-10000-07257	5655 N COMO CIR	91367	3	174B101  1447	2146035***	(Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.17437	-118.61091	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS. TOTAL SYSTEM SIZE: 4.251KW. [INVERTER: POWER ONE AURORA PVI-4.2-OUTD-US] [SOLAR MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5530	17041-10001-34318	8803 1/2 S FIGUEROA ST	90003	8	096A201   156	6038006037	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	PIN	33.95696791	-118.28302568	expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5531	18041-10000-01239	333 S GRAND AVE 14th Level	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR INTERIOR RENOVATION AT 14TH FLOOR PUBLIC SPACE, CORRIDOR, ELEVATOR LOBBY, FOR T-24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA  3160 sq.ft. B#17016-10000-07236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5532	13041-20003-35618	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	33.98173	-118.4029	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE FROM COPPER TO ALUMINUM FEEDERS. ALL CHANGES HAVE BEEN CLOUDED DELTA VE FOR VALUE ENGINEERING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5533	19041-10000-19747	4141 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   250	5045001008	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Issued	05/24/2019 12:00:00 AM	ADDRESS	34.01663	-118.34402	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5534	18041-10000-16152	14006 W RIVERSIDE DR Suite 23A	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Issued	10/24/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	Energy plan check for a retial T.I.  Scope includes new light and equipment. Total area is 1,031-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5535	14041-10000-03079	3411 N WOODCLIFF ROAD	91403	4	159B145   465	2279025005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.13207	-118.46209	PV1, Install 9.5 KW DC roof-mounted solar array on a 1-story home, interconnect with existing service panel.(2)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(38) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5536	14041-10000-07091	1240 S NAOMI AVE	90021	14	121-5A213  54	5130006900	PF-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.02783	-118.24431	2 of 2 systems. Change of engineer and contractor. CARPORT  - NONROOFTOP SOLAR)See 14041-10000-07071 for other system and interconnection fees.PV2 435.6KWdc. 480V. positive GND. NONstd. 1story. Roofmount. [(1) inverters: {Solectrica SGI-266}]. [(660)modules: {SUNPOWER {spr-425-WHT-D}}]     'Expedited plan check per applicant request'previous plan reference: 12041-10000-06288Plan check for 439.22KWdc roof and ground (canopy) mounted system.  The new 1600 A service, switchboard, and lighting plan check under #12041-10000-06291.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5537	14041-20000-17317	3871 S KEESHEN DR	90066	11	111B157   100	4235025021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.00403	-118.42844	PV1Install roof-mounted solar array on SFD. Derating main breaker. System size: 4.3kW(20) EnPhase M215-60-2LL-IG-S22 microinverters(20) Solar World SW 255 MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5538	12041-20000-20760	10366 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM			PC Approved	08/31/2012 12:00:00 AM	ADDRESS	34.25878	-118.57962	existing TI approx 1162 SF for little caesar's. energy only plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5539	14041-20001-20289	834 N KENMORE AVE	90029	13	144B197  1385	5538014008	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.08678	-118.29687	Fee for expedite only.*****New roof mounted PV system with Optimizers.  Total system size 7.6KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5540	16041-20001-33131	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	34.07594	-118.35916	Revisions to approved set.  Changes to lighting design - update of TItle 24 forms.  (((T-24, PC FOR ENERGY ONLY. INTERIOR REMODEL OF EXISITING CAFETERIA. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1245 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5541	18041-20001-38699	3418 E 3RD ST	90063	14	124-5A227 317	5179013026	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2039.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.03452	-118.19579	expeditepv1install roof mounted pv system sized 7.6KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5542	11041-20001-21792	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.32381	-118.49103	Modification to an aproved set of plan.  Modifications are reducing the amount of fixtures in the wharehouse as well as the lay out,.  Plan check is for energy only.  <<<<energy plan check warehouse>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5543	18041-10001-26979	701 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	33.7799	-118.24198	EXPEDITE PER APPLICANT REQUEST. NOTE PERMIT UNDER THE MASTER APPLICATION:NEW PV SYSTEM MOUNTED ON CARPORTS WITH 2000 PV MODULES AND 25 INVERTERS WITH 480 VOLT OUTPUT.SYSTEM SIZE 870KWDC/750KWAC <<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03431	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5544	15041-10000-41338	730 S LOS ANGELES ST	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.04254	-118.25109	NEW FIRE ALARM SYSTEM TO AN (E) MIX USE BUILDING. TOTAL FIRE ALARM DEVICES  291, WITH 5 POWER SUPPLIES AND 1 FIRE ALARM PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5545	14041-10000-24897	6801 W HOLLYWOOD BLVD FLOOR P2	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	"REPLACE EXISTING FACP  WITH NEW FACP MODEL ONLY ON FLOOR P2. NEW MODEL NFS2-3030.""COMPLY WITH DEPARTMENT ORDER effective date08/20/2014. PERMIT NEEDS TO BE PULLED 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5546	19041-10000-28007	4073 W WASHINGTON BLVD	90018	10	126B185   948	5072013035	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM			Reviewed by Supervisor	09/13/2019 12:00:00 AM	ADDRESS	34.04004	-118.328	power pc  for new 800A, 120/240V,3Ph,4W service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5547	11041-10000-01984	101 S THE GROVE DR # G9	90036	4	138B177  1131	5512003038	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM	03/29/2011 12:00:00 AM		Permit Closed	06/07/2011 12:00:00 AM	ADDRESS	34.07256	-118.35874	alterations in an existing retail store -splendid- at the Groveplan chk is for Title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5548	15041-10000-12433	11995 W BLUFF CREEK DR BLDG 4	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	TI FOR 2-STORY YAHOO OFFICE BUILDING - BUILDING 5.  TOTAL  AREA 18548 SQ.  PLAN CHECK FOR POWER AND ENERGY.  LIFE SAFETY AND OPTIONAL STANDBY POWER SUPPLIED BY GENSET ADJACENT TO BUILDING 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5549	19041-20000-52960	11668 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	05/01/2023 12:00:00 AM	ADDRESS	34.20103	-118.38683	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING, CKTS AND RTU IN LABORATORY SPACE. NO HAZARDOUS AREAS. TOTAL SQ. FT. 408.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5550	15041-20001-13769	2186 N MANDEVILLE CANYON ROAD	90049	11	138B133   496	4493003012	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2015 12:00:00 AM			PC Approved	05/19/2015 12:00:00 AM	ADDRESS	34.07624	-118.49874	Plan check for change to approve set of plans add 4 more modules to existing 19 modules; Total 23 PV modules install.  [[[[[Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (19) modules, and (19) power optimizers. Standard plan is not being used.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5551	19041-10000-00144	929 W JEFFERSON BLVD UNIT 1660	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.02454	-118.28546	FIRST TIME TENANT TENANT IMPROVEMENT RETAIL ADDING 200 AMP NEW PANEL ON EXISTING 1000A DISTRIBUTION BOARD SCOPE OF WORK INCLUDES 1271 SQFT.bld# 18016-10000-41276	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5552	19041-10001-43335	5230 E ALHAMBRA AVE	90032	14	138A235    38	5217019020	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.07411	-118.17145	EXPEDITE PER APPLICANT REQUEST ((NEW ROOFTOP SOLAR SYSTEM CONSIT OF 58 MODULES (18 x SOLARBINE SB-S410SA1 and 40 x SHELLSOLAR SQ 150 PC), WITH TWO INVERTERS (1 x SUNNY BOY 5.0US AND 1 x FRONIUS PRIMO 5.0). SYSTEM SIZE 13.38KWdc AND 10KWac CONNECTED TO A NEW 225A SERVICE SERVICE UPGRADE TO BE PERMITTED SEPARATLEY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5553	11041-10000-27492	926 S CROCKER ST # 4	90021	9	124-5A211 165	5132002019	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Finaled	01/12/2012 12:00:00 AM	ADDRESS	34.0355	-118.24971	NEW COMMERCIAL SPACE-FIRST TENANTNEW CIRCUITS AND LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5554	17041-20000-25141	14122 W PINE LANE	91405	2	183B153  1171	2217032037	(T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM			Reviewed by Supervisor	08/02/2017 12:00:00 AM	ADDRESS	34.20141	-118.44096	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5555	13041-10000-32944	9329 N VALJEAN AVE	91343	12	198B137   425	2676008004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.24018	-118.48736	PV1, Install 5.25 kw DC roof-mounted solar array for a one story house, interconnect with the main service panel. Transformerless inverter:SolarEdge SE5000A-US. 21 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5556	18041-20000-06706												Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM				VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5557	17041-20001-19654	17909 W PALORA ST	91316	5	168B129   137	2182006018	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	34.15972	-118.52223	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with AC coupled battery backup system.6kW ungrounded system. (23) 325W pv modules. (1) 5kW Tesla Powerwall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5558	13041-20001-16548	210 W 7TH ST GND FLOOR	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.04461	-118.25275	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA C REVISIONS. CHANGE TO LIGHTING AND T24. CHANGE IN LOADS AND ADDITION OF CIRCUITS. PLAN CHECK FOR POWER AND ENERGY CHANGES DELTA C. ORIGINAL PLANS HAVE BEEN ATTACHED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5559	18041-10000-33648	601 S FIGUEROA ST 48TH FLR.	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR T24 ONLY, TI ON RESTROOM 48TH FLOOR: NEW PLUMBING, NEW LIGHTING, AND NEW FINISHES. TOTAL AREA: 560 SQ.FT(B# 18016-10000-28313)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5560	18041-20001-04920	618 S VAN NESS AVE	90005	4	135B189   927	5504018011	RD3-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.06245	-118.31518	07-12-2018  Changes to an approved set of plan. Changes include relocate panels to garage locaton. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5561	19041-10000-32661	170 S MOUNTAIN VIEW AVE	90057	13	135A205   151	5154005014	R3-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM			Reviewed by Supervisor	08/27/2019 12:00:00 AM	ADDRESS	34.06441	-118.27085	UPGRADING THE SERVICE TO 600 AMP AND REPLACING 36 UNIT PANELS AND THE HOUSE PANEL IN AN EXISTING APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5562	13041-10000-18107	1311 N SAN FERNANDO ROAD	90031	1	147A217   364	5442002908	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			07/10/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.09589	-118.23218	PLAN CHECK FOR NEW FIRE ALARM SYSTEM TO BE INSTALLED FOR NEW APARTMENT BUILDINGS. PLAN CHECK FOR BUILDING 1, 2, AND 3. PERMIT FOR BUILDING 1. (PERMIT 1 OF 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5563	17041-30000-24640	11614 N WOODCOCK AVE	91340	7	213B157   309	2523023006	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.2814	-118.42664	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5564	18041-10000-28641	6628 N SEPULVEDA BLVD	91411	6	180B145   284	2235003004	R4-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Issued	07/31/2018 12:00:00 AM	ADDRESS	34.1911	-118.46591	PLAN CHECK FOR FOR TITLE 24 FOR REMOVAL OF HID FIXTURE TO NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5565	19041-10000-18537	8657 N LINDLEY AVE	91325	12	195B125   886	2786001032	C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.228	-118.52755	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5566	09041-10001-23033	2614 W 7TH ST	90057	1	133-5A201 234	5141013022	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Apartment			05/03/2010 12:00:00 AM	07/23/2010 12:00:00 AM		Permit Finaled	12/15/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	Changes from  previously approved plans indicated Delta 1.  Revised single line diagram to show 2500 amp supplying a 1600 amps switchboard and a 1000 amp switchboard.  New electrical equipment added.  Rerouting service conductors.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5567	15041-10000-33442	545 N KENMORE AVE 1-12	90004	13	141B197   932	5520009008	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.08034	-118.29695	New Fire alarm system to an new 2 story 16 unit apartment building. 1 new fire alarm panel, 24 fire alarm devices, power supply and annunciator panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5568	10041-20000-20036	21115 W OXNARD ST	91367	3	177B105   117	2149005044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/28/2010 12:00:00 AM		Permit Finaled	04/21/2011 12:00:00 AM	ADDRESS	34.17942	-118.59364	T.I. to existing space (L.A. Micro Exchange Group).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5569	13041-10000-25098	777 E 15TH ST	90021	14	123A211   376	5132026034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.02954	-118.25311	TITLE 24 PLAN CHECK ONLY. 1 STORY. 2655 SQFT. WAREHOUSE. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5570	13041-20003-03643	16500 W VENTURA BLVD	91436	5	168B137   382	2284005036	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM			Corrections Issued	04/04/2014 12:00:00 AM	ADDRESS	34.15743	-118.49262	((restamp for original approved set of plans. ))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5571	16041-10000-42723	17328 W TRAMONTO DR 1-8-Bldg 2	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	01/11/2022 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building 4 story 8 units (Type A) . Performance method is being use for Title 24. Total area: 14,623 sq ft.Note: This is 9 buildings submit  in 1 plan. 2 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5572	18041-20000-21658	4170 N CRISP CANYON ROAD	91403	4	165A149   214	2276031018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.14486	-118.45582	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (36) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5573	12041-20000-16199	143 S ROBERTSON BLVD	90048	5	138B169   496	4334001023	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.07399	-118.38391	Underground Service upgrade to 800A in a methane zone.  Plan check for power and energy.  (Engineer has designed plans to methane Level V in liu of  providing a methane report.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5574	12041-10000-19110	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	Install new lighting and new receptacle outlet to existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5575	15041-20001-33219	2975 N TIFFANY CIR	90077	5	156B149    11	4379034008	RE15-1-H-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.12813	-118.44633	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5576	16041-10000-38895	13065 W VICTORY BLVD	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.18923	-118.41748	"Full PC for Power and energy. Tenant Improvement and Change of use of a portion of an existing retail building to a new dental office. Total affected area is 1892 sq. ft.   ""COMPLY WITH DEPARTMENT ORDER effective date 07/13/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5577	11041-20000-03913	11126 W CHANDLER BLVD	91601	4	171B173   166	2350015043	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.168	-118.37334	Plan check for new roof mounted PV system (22.77 KW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5578	11041-20000-19987	19500 W PLUMMER ST #G	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM			PC Info Complete	02/29/2012 12:00:00 AM	ADDRESS	34.2426	-118.55846	PLAN CHECK POWER AND ENERGY FOR NEW BUFFALO WILD WINGS RESTAURANT IN BUILDING G (SEPERATE BUILDING) WITH EXISTING SERVICE SUPPLIED FROM MS4 IN BUILDING E/F. EXISTING MULTIPLE FEEDERS SUPPLYING BUILDING G. MODIFICATION TO SEPERATE FIRE ALARM  SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5579	16041-30001-32907	13050 W SAN VICENTE BLVD #101	90049	11	129B137   501	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.0483	-118.49125	12/13/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes include the removal of all fire alarm devices/notes on plan set.*****Previous Work Description*****Plan Check for T-24 only.  TI on (E) retail space. Install new lightings and receptacles, new 200A panel. Total affected area: 1,495 sq.ft((B# 16016-10000-21242))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5580	17041-10000-41531	10250 W SANTA MONICA BLVD # 9192-& 9194	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	PIN	34.0586034	-118.41904766	"FULL PLAN CHECK (POWER+ENERGY) FIRST TIME TENANT SPACE  (UNIT# 9192, 9194), ADDING (1) PANEL FOR EACH TENANT TO LANDLORD'S DIST BOARD ""ELB1801DLB"", TOTAL AREA FOR #9192 IS 320SQ.FT, AND FOR #9194 IS 450SQ.FT(B# 13016-10036-16108)"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5581	14041-10000-23396	12200 W OLYMPIC BLVD	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			PC Info Complete	11/07/2014 12:00:00 AM	ADDRESS	34.03195	-118.45506	PLAN CHECK FOR POWER AND ENERGY FOR IT ROOM IMPROVEMENT AND CHANGES TO EMERGENCY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5582	19041-20000-12595	19458 W OXNARD ST	91356	3	177B117   728	2153031015	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.17817	-118.55704	Plan check for PV roof mounted system, system size: 13.44KW AC, 15.12KW DC with 42 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5583	17041-20000-11309	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLANCHECK FOR T24 ENERGY. ENTRY CANOPY AND CANOPY  LIGHTING. 661 SQFT.BUILDING PERMIT #  16016-10000-29076	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5584	13041-10001-27864	9350 N NAGLE AVE	91331	6	198B153   473	2642011017	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.24007	-118.4366	PV1 2.5KWdc. 240V. xmfrLESS/Ungnd. nonSTD. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(10)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]     'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5585	16041-20000-14666	16611-16615 W ARMINTA ST	91406	6	189B137    29	2205009031	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.21497	-118.49472	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 80KW INTERCONNECTED TO UTILITY GRID.$0 permit fee is due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5586	13041-10002-34677	1200 S GRAND AVE	90015	14	126A207   138	5139023907	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			01/19/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	ADDRESS	34.03989	-118.26331	01/19/16Changes to an approve set. All changes are made under delta 28.1. Changes include changing type A units to 100A breakers, updated voltage drop calculations, adding emergency photometrics, and updating title 24 forms.Note: permit pulled under PCIS#13041-10000-34677 permit pulled under pcis#13041-10000-34677((((((FULL PLAN CHECK FOR  New 7 Story (5 Story over 2 Story Podium) Mixed Use Building w/ 287 Unit Apartment & Retail Building over two level parking basement. PROJECTED AREA FOR LIGHTING WORK IS APPOXIMATELY 344,451 SQ FT AREA. SERVICEbuilding permit under: 13010-10001-02721, DESCRIPTION LISTED AS 347 UNITS; ELECTRICAL PLANS WERE BASED ON CALCULATIONS FOR 300 UNITS (REFER TO SHEET 1E0.03 )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5587	17041-20001-38696	8913 N MEGAN AVE	91304	7			(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	34.23225	-118.60631	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5588	12041-20000-12128	17563 W VENTURA BLVD	91316	5	171B129   344	2257008049	(Q)C4-1VL, (Q)P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM	05/25/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.16207	-118.51633	office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5589	16041-20000-34008	340 N OXFORD AVE	90004	13	138B193   242	5521028019	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			09/26/2016 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.07736	-118.30783	PLANCHECK FOR POWER AND ENERGY.  NEW 4-STORY  10 UNITS  APARTMENT BUILDING.fire alarm variance has been submitted.BUILDING PERMIT # 15010 10000 01376	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5590	17041-10000-17177	717 S CABRILLO AVE	90731	15	015B197   536	7454001001	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	33.73746	-118.29469	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 6,600 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5591	15041-10000-34866	8985 W VENICE BLVD	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.02733	-118.39241	ALTERATIONS IN AN TMOBILE RETAIL STORE.PLAN CHK IS FOR TITLE 34	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5592	19041-20000-28143	3860 S 3RD AVE pv1	90008	10	117B189  1008	5034017047	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Issued	08/06/2019 12:00:00 AM	ADDRESS	34.01608	-118.32022	pv1install roof mounted pv system sized 5KW AC interconnected with msp.this is an addition to an existing system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5593	11041-20000-24473	1015 S ABBOT KINNEY BLVD	90291	11	109-5A143 427	4286012001	C2-1-CA	West Los Angeles	Venice	Venice		2733.00, 2734.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	33.99226	-118.4722	pv system mixed use building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5594	13041-10000-34377	20330 W VIA MEDICI	91326	12	219B113   126	2701045007	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.29433	-118.57714	PV1, install 11 kw DC roof-mounted solar array for a 2-story house, interconnect with main panel. (2)Transformerless inverter(s): Solaredge SE3800A-US and Solaredge SE6000A-US. (44) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5595	17041-10000-07839	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	Yes	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Issued	06/20/2017 12:00:00 AM	ADDRESS	34.24912	-118.34256	Plan check for PV roof mounted system. System size:  6kW with 21 modules and 1 inverter (6.0kW) with Tesla battary back up (DC coupling).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5596	14041-20000-31948	1333 N SAN PABLO ST	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for power only. Install new 600A Motor Control Center for new air handling unit on roof of existing 3-story USC research laboratory.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5597	17041-10000-40164	1615 S STAUNTON AVE	90021	14	120A213   242	5167002044	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.02271	-118.24157	Remove HID fixtures and replace with new LED fixtures  T-24 only.6100 SQ.FT OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5598	18041-10000-09158	3516 S HUGHES AVE	90034	5	120B165    48	4313010044	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.02869	-118.40278	"PLAN CHECK FOR TITLE 24 ONLY FOR TI - Addition of 22'4"" x 8'0"" walk-in cooler and convert (e) Retail space to Food Catering Establishment - TOTAL AFFECTED AREA = 991 SQ. FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5599	12041-10000-04335	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	33.89279	-118.28725	NEW FIRE ALARM SYSYTEM FOR ONE STORY BLDG, STRIP MALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5600	17041-20004-22682	3530 W WILSHIRE BLVD	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.06154	-118.30122	04/01/2019 Changes to an approved set of plans. Indicated feeders have changed from CU to AL (AC.2 and AC3.1).*****Previous Work Description*****Removal of separate AC disconnects at inverter locations. Inverters have integral AC disconnects.$0 plan check fee per State Senate Bill SB 1222.  3/7/2019CHANGE TO APPROVED SET, CHANGE FROM 688 PHONO SOLAR 325W PV MODULES TO 649 HANWHA Q CELLS 390W PV MODULESTHIS IS PLAN CHECK ONLY.7/31/2018changes to an approved set of plans.  changes to reduce system size to 180KW AC with line side tap.  (688) phono solar 325W(3) yaskawa solectria 60KWThis is plan check only.*****Original Scope of Work*****Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,054) modules, and (1) load center on parking structure. Note: Permit Fees $0 Due to SB 1222 Note: Building application has been generated under 17014-30000-03172	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5601	19041-20000-47416	11942 N CARABELA CT	91326	12	216B109   162	2701081011	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	34.28995	-118.58303	Install 27 kWh energy storage system and associated distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5602	19041-20000-23665	1759 S SHENANDOAH ST pv1	90035	5	129B169  1286	4303008020	R1V2	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.04672	-118.38299	pv1install roof mounted pv system sized  6.3KW AC interconnected with msp.(1) tesla ESS rated 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5603	14041-20000-17358	300 S GRAND AVE 22nd floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for energy only. New lighting (incl. emergency) on 22nd floor of high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5604	19041-10000-44760	12661 W SARAH ST	91604	2	168B161   877	2362024031	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	12/28/2019 12:00:00 AM	ADDRESS	34.1541	-118.40901	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 14.08KVA PV1 SYSTEM CONSISTING OF 44 MODULES, 44 MICRO INVERTERS(IQ-7X) WITH COMBINER BOX CONNECTED TO EXISTING 400A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5605	15041-10000-05681	11985 W BLUFF CREEK DR	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	(N) fire alarm system for building 4 core and shell.  (N) FACP and (16) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5606	17041-10000-45093	1220 W 256TH ST	90710	15	036B197   945	7413004036	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	33.79177	-118.29815	REPLACE EXISTING INDSOOR & OUTDOOR FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5607	13041-20001-26325	1205 W 3RD ST	90026	1	132A209    95	5152013019	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	PIN	34.05699675	-118.25804943	New restaurant.  PLAN CHECK FOR POWER ONLY REQUESTED BY THE APPLICANT.   Load is less than 400 amps. T-24 AND EMERGENCY LIGHTING PLAN CHECK ARE ON THE MAIN APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5608	19041-10000-04436	4840 S ALLA ROAD	90066	11	105B157   569	4223008010	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM			Corrections Issued	02/06/2019 12:00:00 AM	ADDRESS	33.98258	-118.42922	PC FOR NEW FA SYSTEM IN A NEW 2-STORY OFFICE BUILDING (OFFICE BUILDING 3). SCOPE INCLUDES FA PANEL, ANNUNCIATOR, CELL COMMUNICATOR AND 41 DEVICES. DUCT SMOKE DETECTORS, TAMPER SWITCH, FLOW SWITCH AM SMOKE FIRE DAMPERS ARE CONTRACTED BY OTHERS AND NOT PART OF THIS BATTERY CALCULATIONS. ** {PC only is set because plans were approved under a seperate permit number 19041-10000-13136}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5609	17041-10000-41120	333 S GRAND AVE 16th FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC for T24 only for new lighting in common area of 16th floor. Reconnecting to existing local circuits.Total of 3699sqft. B#17016-10000-07584	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5610	15041-10000-08940	7470 N FIGUEROA ST	90041	14	162A231    31	5709001014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.13993	-118.18696	PC FOR NEW FA SYSTEM WITH 174 FA DEVICES AND ONE CONTROL PANEL. B OCCUPANCY AN A3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5611	13041-20000-04704	500 W WORLD WAY 5R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	Two new signs for Coffee Bean at LAX Terminal 5, Space 5R.  PLAN CHECK ONLY FOR T-24.  PERMIT FEES ARE UNDER INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5612	13041-20000-12178	20216 W LORENZANA DR	91364	3	171B113   157	2166040005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.16619	-118.57408	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SIZE 11.76 KW. USING 48 MODULES. CENTRAL INVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5613	12041-20001-19219	5610 W PARK OAK PL	90068	4	153B193    64	5580029008	RE15-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2012 12:00:00 AM			PC Approved	10/24/2012 12:00:00 AM	ADDRESS	34.11682	-118.31162	Change to previously approved set of plans. one module was moved from one string to the other. Original on 12041-20001-19219.pv system single family	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5614	18041-20000-00413	13100 W GRIDLEY ST	91342	7	222B161    19	2512027030	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.30958	-118.41836	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (10) modules, (1) load center, and (1) Tesla PowerWall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5615	16041-10000-18538	5921 W CENTER DR 1-95	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	33.97588	-118.38747	FA SYSTEM WITH 447 DEVICES AND 4 PANELS***PLAN CHECK FOR PHASE 1 CONSTRUCTION ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5616	10041-10000-21754	267 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Closed	05/12/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY  ( 2-DAYS ) STANDBY GENERATOR  TO SUPPLY POWER TO EACH OF TWO MCC WHICH POWERS EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5617	15041-10000-21208	3028 N BROADWAY	90031	1	138A223    69	5208004002	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	PIN	34.07336352	-118.20961987	TENANT IMPROVEMENT IN A WABA GRILLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5618	11041-20000-18829	11417 W MIRANDA ST	91601	4	174B169   394	2338024025	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.17503	-118.37973	"Plan check T24 Energy/Emergency lighting for change of use from single family dwelling to office. ""COMPLY WITH DEPARTMENT ORDER effective date 04/28/2009. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5619	14041-10000-04164	1741 W KENT ST	90026	13	138A207    42	5404006021	RD2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.07377	-118.26295	PV1, Install 6.5 kW DC roof-mounted solar array on a two-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 6000A-US-ZB-U. (26) Modules: CANADIAN SOLAR CS6P-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5620	19041-20001-33536	23416 W CANZONET ST	91367	3	171B093   306	2044019005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.16629	-118.63699	EXPEDITED.PV1. INSTALL 15.84 KW DC ROOF MOUNTED SOLAR SYSTEM WITH (44) MODULES AND MICROINVERTERS (IQ7PLUS-72-2-US).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5621	11041-20000-18347	10663 N YARMOUTH AVE	91344	12	207B129   528	2733005027	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.26411	-118.52176	T.I.  Creating two offie spaces within a commercial space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5622	12041-10001-10243	345 S GRAMERCY PL 1-46	90020	4	135B193   386	5504024081	R4-1	Central	Wilshire	Greater Wilshire		2117.03	Electrical	Electrical	Apartment			06/04/2013 12:00:00 AM			PC Approved	06/04/2013 12:00:00 AM	ADDRESS	34.06755	-118.31312	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 12041-10000-10243. CHANGES MADE TO CIRCUITS 7, 9 AND 10.*********************************************************************12041-10000-10243 DESCRIPTION: New Fire Alarm system for a new apartment complex.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5623	18041-20001-13827	1422 N DEVLIN DR	90069	4	144B169    44	5560001023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM			PC Approved	04/11/2019 12:00:00 AM	ADDRESS	34.09493	-118.3872	supplemental plan check only, addition of lighting pages, change in panel schedules, and change on power floor plans, removed roof from scope of work. clouded changes only.*original*PC for power for new SFD with 600A service.  Installing new service, panelboards, lights, receptacles and equipment. Electrical permit issued under combination permit 15010-10000-00932.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5624	18041-20000-16642	13271 N GLENOAKS BLVD	91342	7	225B149   332	2505001029	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.31207	-118.45576	Plan check for PV roof mounted system, System size: 13.1kW with 38 AC Modules connected to 400A panel.Fees $73.73 due to California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5625	12041-20000-16747	5006 N SAN FELICIANO DR	91364	3	168B101   141	2169008022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.1597	-118.60872	Enphase system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5626	15041-20000-03747	6840 N GARDEN GROVE AVE	91335	3	183B125   881	2125029002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.19517	-118.52936	pv1install roof mounted pv system sized 3.2kw interconnected with msp.(15) sunmodules sw245(15) microinverter enphase m215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5627	14041-20001-18016	7439 N OSTROM AVE PV1	91406	6	186B133   566	2203017011	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Expired	08/24/2016 12:00:00 AM	ADDRESS	34.20592	-118.50777	Upgrade from from 3KW to 3.8 PV1 roof-mounted system, from (12) Trina Solar modules TSM-255P to (15) module including optimizers, and inverter from Power-One PVI 3.0 to Solaredge SE38000A (((INSTALL ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM (3.06KW - USING 3.0 KW INVERTER)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5628	17041-10000-25048	5420 W JEFFERSON BLVD	90016	10	120B177   733	5047014004	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.02556	-118.36431	Plan check for title 24 only in existing space, re place indoor and outdoor existing fixtues with LED fixtures. Total area: 36,050  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5629	14041-20001-06177	4423 N COLDWATER CANYON AVE	91604	2	165B161   226	2362013023	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			03/06/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	34.15104	-118.41397	((EXPEDIE FEES))PV2 ROOFMOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5630	17041-20001-12522	5954 N SIMPSON AVE	91607	2	177B169   852	2339001032	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM			PC Approved	04/28/2017 12:00:00 AM	ADDRESS	34.17914	-118.38873	expeditepv1install roof mounted pv system sized 16kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5631	18041-10000-43988	1416 N RAVENNA AVE	90744	15	036B205  1043	7421026011	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	33.79154	-118.26871	PV ADDITION TO EXISTING SYSTEM ON A SINGLE FAMILY DWELLING. SCOPE INCLUDES 14 MODULES (HANWHA QPEAK 310) AND 14 MICRP-INVERTERS (INPHASE IQ-7-60-2-US 240V). NEW SYSTEM SIZE IS 4.34KWdc AND 3.36 KWac. PORTION OF THE PERMIT FEES ARE PAID UNDER EXPRESS PERMIT (18041-90000-42380). INSPECTOR REQUESTED PLAN CHECK	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5632	19041-20000-35844	15618 W DORIAN ST	91342	7	225B145   141	2501024008	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.31561	-118.47176	PV1. INSTALL 13.33 KW DC / 12.17 KW AC ROOFMOUNTED SOLAR SYSTEM. (43) MODULES AND OPTIMIZERS WITH (1) SOLAREDGE (SE11400H-US) INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5633	17041-20000-16632	1465 N TAMARIND AVE	90028	13	147A191    91	5545014004	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM			PC Info Complete	05/18/2017 12:00:00 AM	ADDRESS	34.09754	-118.31918	PLAN CHECK ONLYti to a new 2 story building.  service under 50kva per tenant.  plan check for energy only.  total connected load less than 400 amps.  total square footage 5058.PERMIT WAS PULLED UNDER 18041-20000-06620 AND 18041-20001-06620	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5634	13041-20000-19515	6265 N SEPULVEDA BLVD	91411	6	177B145     9	2242009035	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM			PC Approved	07/23/2013 12:00:00 AM	ADDRESS	34.18453	-118.46646	T24 FOR EXISTING SPACE USED FOR RETAIL. TOTAL SQRFT 1617.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5635	18041-20000-21921	6767 W FOREST LAWN DR #112	90068	4	162B181   617	5581028005	C1-1D-RIO	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.14432	-118.33993	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,403 sq. ft.Note: Building permit has been issued under 18016-20000-18338	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5636	09041-10001-07914	4953 W FRANKLIN AVE	90027	4	150B197   819	5589014022	R2-1XL	Central	Hollywood	Greater Griffith Park	YES	1892.00	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM	01/08/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.10552	-118.2975	Changes to approved plans made to the lighting and power plans.  Inverter removed ; emergency --> unit equipment, new ckts added to previously approved panels.  Service loading approved after pher phase calculations take receptacle demand into account + 100% rated panels.  P/C is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5637	11041-10000-04083	3810 S AVALON BLVD	90011	9	115-5A207 158	5121007036	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Issued	06/01/2011 12:00:00 AM	ADDRESS	34.01157	-118.26506	400 AMP SERVICE UPGRADE.  SINGLE STORY RETAIL SPACE.  THIS 400 AMP SERVICE TO PROVIDE POWER TO 3810, 3812,3814.  3 EMPTY PANELS.  <<<<<<<<BUILDING ON SAME LOT WITH 1000 AMP SERVICE UPGRADE TO BE FILED UNDER PCIS# 11041-10000-04081	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5638	17041-20000-39909	15301 W VENTURA BLVD Suite 250	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for energy only. TI to office suite 250 in high rise building. New lighting (incl. emergency) - 3,707sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5639	18041-10000-21765	2827 S SANBORN AVE	90291	11	105A145   276	4227019011	R1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	33.9817	-118.46522	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 3.8KWAC /4.55KWDCSCOPE INCLUDES 14 MODULES AND CENTRAL INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5640	19041-20000-47843	6106 N ETHEL AVE	91401	2	177B161   646	2331019003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.18141	-118.41805	PV1. INSTALL 4.62 KW DC PV SYSTEM WITH (14) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5641	16041-20000-23803	883 W 9TH ST	90731	15	015B197   863	7454008002	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	33.73594	-118.29639	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES.  2713 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5642	12041-20000-06073	4459 W SUNSET BLVD	90027	4	147A201   112	5542009014	C2-1D	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.09799	-118.28651	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5643	15041-20000-28871	2401 S VERMONT AVE	90007	8	123B197   510	5054026031	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.03441	-118.29176	replacement of 800A service equipment due to damaged unit. replacement of 2 sections only. no change in load, service entrance or subpanels. replacement is like for like.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5644	18041-20000-29777	20809 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.29522	-118.58702	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5645	14041-20001-29888	1722 N BRIDGEPORT DR	90065	1	148-5A219  34	5464028047	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2014 12:00:00 AM			PC Approved	11/14/2014 12:00:00 AM	ADDRESS	34.10275	-118.22741	EXPEDITE PER APPLICANT REQUEST[PV1Install roof mounted solar array on SFD. Interconnect with 200A MSP.System size 6kW. Grounded system.20 327W pv modules across 3 strings (6+7+7).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5646	13041-20001-30932	735 S FIGUEROA ST LEVEL M3-#303	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	34.04878	-118.26079	((CHANGES TO APPROVED SET OF PLANS. ADDITION OF 3 CIRCUITS. NEW LOADS PROVIDED. ALL CHANGES CLOUDED DELTA C AND DELTA R-10)))) IN ADDITION, THERE WAS NO CHANGE OF ENGINEER. ORIGINAL APPLICATION SHALL HAVE ENGINEER UNDER LICENSE #17722 AS ENGINEER ON RECORD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5647	19041-10000-08487	501 S SHATTO PL 5th flr	90020	13	135B197   762	5077003032	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.06509	-118.29014	pc t-24 only for 2 rest rooms in the 5th floor, area of scope is 366sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5648	15041-20000-41525	8508 N SHIRLEY AVE	91324	12	192B117   265	2783019002	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.22491	-118.5578	PV1.  Install 6 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.  (20) LG 315N1C-G4 w/ SolarEdge SE6000A-US transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5649	19041-10000-16434	15740 W ADDISON ST	91436	5	171B141   478	2261004004	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.16155	-118.47613	{EPLAN}PLAN CHECK FOR A ROOF MOUNTED 10KVA PV SYSTEM  CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 42 MODULES USING P320 OPTIMIZERES CONNECTED TO EXISTING 200A PANEL .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5650	17041-10000-14296	1400 S LOS PALOS ST	90023	14	117A229     8	5192001001	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.01638	-118.19487	PC FOR POWER AND ENERGY FOR COLD STORAGE FACILITY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5651	19041-10000-15283	5710 S CRESCENT PARK EAST	90094	11	102B157   266	4211020221	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	33.9718	-118.42824	PC FOR T24  ENERGY ONLY FOR  PROPOSED INTERIOR REMODEL TO EXISTING GROUND FLOOR MAIL ROOM IN EXISTING APRTMENT BUILDING.WORK INLCUDES NEW PANEL, LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA 556 SQ.FT B# 19016-10000-12133	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5652	13041-20000-13505	8319 N LANKERSHIM BLVD	91605	6	192B169   465	2310006001	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.00	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.22169	-118.38815	RESIDENTIAL UNIT TO OFFICE. NO CHANGE IN LOADS. NEW LIGHTING FIXTURES. PC FOR T24 ENERGY ONLY. TOTAL AREA 1144 SQ FT. (((PC FOR CONTROLS ONLY. ALL FIXTURES EXISTING)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5653	15041-20000-15227	6250 N TOPANGA CANYON BLVD #1593	91303	3	177B101    64	2146029002	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	PIN	34.18329557	-118.60538018	Plan check for 1st time tenant Peet's Coffee House at Topanga Village. Total area: 1,696 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5654	17041-20000-21186	20417 W ELKWOOD ST	91306	3	189B113   948	2107013045	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Issued	07/06/2017 12:00:00 AM	ADDRESS	34.21245	-118.57776	Plan check for solar pv system, roof-mounted on SFD.10kW ungrounded system. (33) 330W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5655	19041-20001-51556	4521 N CARPENTER AVE	91607	2	168B169  1023	2364006026	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.1527	-118.39116	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 19.8 KW DC/18.9 KW AC. SCOPE OF WORK CONSISTS OF (60) PV MODULES WITH MICROINVERTERS, AND A LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5656	14041-10000-12170	4574 W ADAMS BLVD	90016	10	123B181  1006	5050003026	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.03239	-118.34027	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. 27 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5657	14041-10000-26012	1100 N BEL-AIR ROAD	90077	5	144B153    23	4370028024	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Expired	03/30/2017 12:00:00 AM	ADDRESS	34.09431	-118.4434	PLAN CHECK FOR POWER AND ENERGY FOR 2 STORY SFD WITH 800 A SERVICE. bldg#13010-10003-00965.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5658	14041-10000-20747	9121 N LEV AVE	91331	6	195B161    48	2628008008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.23509	-118.41768	PV1 4KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(16)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5659	18041-20000-44677	707 W WILSHIRE BLVD 6th-7th-flr	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.04893	-118.2572	PC POWER AND T-24 FOR 2 FLOORS 6TH AND 7TH IN AN OFFICE BUILDING. WORK INCLUDE ADDING 2 112.5KVA TRANSFORMERS. PANEL 7E DOES NOT EXIST IN THE PANEL SCHADUEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5660	12041-20001-28214	8987 N LAUREL CANYON BLVD	91352	6	195B165   219	2629019012	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.2326	-118.40475	(( THIS PLAN CHECK COVERS CHANGING BREAKER TYPES ONLY. THIS IS A PLAN CHECK ONLY APPLICATION ))New shell only for a Medical Clinic.  Full plan check required.  Clinic will be licensed and must be check for OSHPD-3. Fire Alarm Variance has been filed.T. I. ENTIRE MED. CLINICS AND OFFICE BUILDING. ( SEE PLAN CHECK B12VN12624 FOR BUILDING SHELL AND CHANGING THE USE PERMIT )--MEDICAL CLINICS WITH NO CHRONIC DIALYSIS AND/OR SURGICAL SERVICE, NOT PLAN REVIEWED  FOR OSHPD III.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5661	15041-10000-20363	707 W WILSHIRE BLVD 21 FLR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOE ENERGY AND EMERGENCY LIGHITNG.  SCOPE OF WORK TO BE IN THE 21ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5662	10041-20000-05123	1020 S OLIVE ST	90015	9	127-5A209 286	5139012008	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	06/09/2010 12:00:00 AM		Permit Closed	12/23/2011 12:00:00 AM	ADDRESS	34.04162	-118.2599	Plan check temporary power 800 Amp switchgear and equipment for construction site. Site is in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5663	19041-20000-03922	10824 W BURBANK BLVD Ste D	91601	2	174B173  1015	2416014016	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.17199	-118.3668	TI to (E) commercial office space.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5664	13041-10000-07013	9727 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.24624	-118.4193	PLAN CHECK FOR POWER AND ENERGY FOR NEW ROSS RETAIL STORE IN EXISTING BUILDING. 600A FEEDER SUPPLYING ROSS STORE PLAN CHECK UNDER #13041-20000-09822. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5665	13041-20000-25688	12618 W EVERGLADE ST	90066	11	114B153   300	4247026019	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM			Corrections Issued	09/17/2013 12:00:00 AM	ADDRESS	34.01102	-118.44362	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.1KW AC USING 10 MODULES. USING ENPHASE M215. MICROINVERTER. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5666	10041-20000-04187	7618 N JELLICO AVE	91325	12	186B129   195	2202002012	RA-1-K	South Valley	Reseda - West Van Nuys			1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2010 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.20915	-118.51727	PHOTO VOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5667	19041-20001-05322	2701 N GLENDOWER AVE	90027	4	153B197   104	5588020030	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.11628	-118.29464	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5668	16041-20001-43524	11014 W PEORIA ST	91352	7	201B173   358	2538013003	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2016 12:00:00 AM			PC Approved	12/19/2016 12:00:00 AM	ADDRESS	34.24526	-118.37089	expedite per applicantpv1install roof mounted pv system sized 16.9kw (ACM) interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5669	16041-20001-13987	3671 N BERRY DR	91604	2	162B173   918	2378025029	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM			Reviewed by Supervisor	05/06/2016 12:00:00 AM	ADDRESS	34.13712	-118.37878	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 7.6kW. Ungrounded system. Each module has a 300W power optimizer.(33) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5670	19041-20000-17522	421 S OCEAN FRONT WALK	90291	11	109-5A141 140	4286029006	R3-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	33.99352	-118.47935	ti to an existing commercial building.  adding new lighting new controls to existing panels. plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5671	16041-20001-33712	5441 N WILLIS AVE	91411	4	174B149  1148	2249026004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM			Corrections Issued	10/04/2016 12:00:00 AM	ADDRESS	34.16972	-118.45546	PV1.  Install 11.04 kW grid tied photovoltaic system.  (32) SunPower AC modules with 100A solar load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5672	17041-10000-39189	725 S FIGUEROA ST # 4050	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5673	11041-20001-17463	5404 S JANDY PL 1st & 2nd-floor	90066	11	105B161   885	4211006004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Approved	04/17/2012 12:00:00 AM	ADDRESS	33.98159	-118.41622	Changes from previously approved plans.  Install additional lights in the open office area.  Plan check for energy.  All changes are clouded on the plans.*****PLAN CHECK POWER AND ENERGY FOR T.I. TOMS SHOE'S BUILDING. EXISTING SERVICE.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5674	10041-10000-19979	12265 W VENTURA BLVD #202	91604	2	162B165   111	2367017016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.14328	-118.40035	TI IN AN EXISTING COMMERCIAL SPACE IN SUITE #202.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5675	16041-10000-26319	623 N AVENUE 64	90042	14	156A233   419	5493008015	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.11963	-118.17862	Plan check for T-24 only. Remove exterior lights of HID fixtures and replace with new LED fixtures. Total affected area: 17,728 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5676	16041-10000-10435	6600 N TOPANGA CANYON BLVD SUITE 183H	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	New Total Woman Gym inside an (E) space at Topanga Mall.  400A panel and 100A subpanel ties to an (E) 2000A service. Total estimated new load 432A. Total area 10,373 sq.ft.**No Build. Application submitted as of 3/24/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5677	13041-10000-28950	9539 W OAKMORE ROAD	90035	5	129B165   753	4306024015	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.04776	-118.39651	PV1.  Install 5.5 kW DC roof-mounted solar array, interconnect with main service panel.  Enphase M215 microinverters.  22 modules: Phono Solar PS250P-20/U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5678	16041-10000-44228	22255 W CHATSWORTH ST	91311	12	207B101    61	2723006026	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.26453	-118.61234	"Fees are $0 due to senate bill 1222.PV1 roof mounted solar system installation to single family home. Instralling 56 microinverters rated at 250 watts each for a total system size of 14KW. Inspector to verify installation of bottom of conduit to be mounted more 1/2"" above the roof."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5679	19041-10000-07780	6301 S BROADWAY	90003	9	105B201  1074	6005002045	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Info Complete	08/27/2019 12:00:00 AM	ADDRESS	33.98218	-118.27851	FULL T.I. PLAN CHECK FOR NEW 7-ELEVEN CONVENIENCE STORE. SCOPE INCLUDES EXISTING 600A SERVISE NEW 600A SWITCHBOARD, PANELS, EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 3163 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5680	13041-10000-08695	20054 W VENTURA BLVD	91364	3	174B113   486	2166043009	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	05/16/2013 12:00:00 AM	ADDRESS	34.17092	-118.57037	13041-10000-08695T24 FOR EXISTING STARBUCKS COFFEE. 1374 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5681	15041-10001-12036	380 WORLD WAY T 93	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM			PC Approved	09/25/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	(9/25/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE REVISIONS TO THE LIGHTING FIXTURES AND ENERGY CALCS.  THIS IS PLAN CHECK ONLY. Title 24 plan check only.  Total area = 360 sq. ft.T.I. to existing commercial kiosk in the airport.  Lighting, recepticles, and one new 225A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5682	17041-10000-30473	18526 S NORMANDIE AVE	90248	15	060B197   201	6109006053	P-1, [Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	33.86235	-118.29905	TITLE 24 PLAN CHECK TO REMOVE EXISTING (8) HID FIXTURES AND REPLACE WITH LED FIXTURES. 13125 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5683	18041-10000-47988	4601 W SUNSET BLVD	90027	13	147B197   660	5542015030	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.09834	-118.28981	INSTALLING 20 EVSE-RS CHARGERS ON EXISTING 800 AMP SWITCHBOARD WITH 8 TESLA FAST CHARGERS WITH APPROXIMATE 267KVA CONNECTED LOAD .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5684	19041-10001-32028	110 E 9TH ST 3rd floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	08/10/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Change to an approved set by removing all track lighting from the floor plan. All changes under delta-2 and 3 only(((Energy plan check for a partial office T.I located on the 3rd floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 13,481-SQ FT Note: Using Exisitng Circuits )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5685	14041-20001-00012	20437 W SCHOENBORN ST	91306	3	192B109   654	2781026002	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.2211	-118.57918	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. 4 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5686	10041-20000-13286	624 S GRAND AVE	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	PIN	34.04778206	-118.25563275	CUTOVER (MOVING LOADS) FROM  BUSS DUCT U2 TO U3,  DS3OU1, DS24U1, DS16U1, DS04U1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5687	19041-10000-49300	1035 S BERENDO ST	90006	1	129B197   356	5078012900	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			12/02/2019 12:00:00 AM	12/02/2020 12:00:00 AM		Permit Finaled	01/27/2023 12:00:00 AM	ADDRESS	34.05172	-118.29388	FULL PLAN CHECK FOR A NEW BUILDING. SCOPE INCLUDES NEW 1600A  120/208 3PH 4W SERVICE WITH AN 800A HOUSE DISTRIBUTION BOARD AND 2 X 600A APPARTMENT UNTIS DISTRIBUTION BOARDS. TOTAL AFFECTED AREA 34936 SQ.FT. 100% AFFORDABLE HOUSINGPER BUILDING PERMIT #19010-10000-03981: NEW 6 STORY APARTMENT BUILDING 42 UNITS, 5 STORY TYPE IIIA OVER 1 STORY TYPE IA OVER 1 LEVEL TYPE IA SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5688	17041-10000-04274	2330 E SANTA ANA BLVD SOUT	90059	15	088-5A217 659	6067027031		Harbor				2913.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM				Plan check for Title 24 only in existing space  replace outdoor HID fixtures with new LED fixtures. Total area: 28,750 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5689	10041-10000-01079	2880 W ROWENA AVE	90039	4	151-5A205 223	5434035027	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM	01/21/2010 12:00:00 AM		Permit Finaled	02/04/2010 12:00:00 AM	ADDRESS	34.1079	-118.26736	Convert storage to classrooms.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5690	18041-20000-38185	3431 S CATALINA ST	90007	8	120B197   729	5040019016	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			10/05/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM	ADDRESS	34.0246	-118.29404	Plan check for new multi residential building 7 units 4 story 600A Service, Total area: 8829 sq ft. B#17010-40000-04295	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5691	11041-20000-12103	6420 W WILSHIRE BLVD 1100	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR T.I. #1100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5692	10041-10000-13961	14006 W RIVERSIDE DR # 64	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	08/10/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	"INTERIOR, NON-STRUCTURAL TENANT IMPROVEMENT TO EXISTING RETAIL LEASE SPACE FOR ""TUMI"" RETAIL STORE; 1499 SQplan chk is for title 24 and 1 ea emergency ckt"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5693	11041-10000-02482	532 S ARDEN BLVD	90020	4	135B189   760	5505020005	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.06426	-118.32561	INSTALLATION OF 13.43KW PHOTOVOLTAIC SYSTEM ON THE ROOFS OF A SFD AND DETACHED GARAGE. PERMIT HAS BEEN OBTAINED ON 10041-10000-23405	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5694	19041-10000-39287	3580 W WILSHIRE BLVD SUITE 400	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	03/01/2020 12:00:00 AM	ADDRESS	34.06156	-118.3028	T-24 PLAN CHECK FOT A TI TO WCUI SCHOOL OF MEDICAL IMAGING AND NURSING. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 3512 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5695	11041-20001-17001	8401 N VAN NUYS BLVD #26	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM			PC Approved	11/30/2011 12:00:00 AM	ADDRESS	34.22308	-118.44896	Revision to lighting for P.C. 11041-20000-17001(LIGHT. FIXTURES ARE REDUCED TO 1 FOR 8 HYGINE ROOMS )PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO DENTAL OFFICE. NEW LIGHT FIXTURES ON EXISTING LIGHTING CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5696	14041-10002-25414	1737 N LAS PALMAS AVE 1-82	90028	13	148-5A185  43	5547010004	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			08/29/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.1026	-118.33639	"DELTA  A REVISIONSCHANGES ARE CLOUDED AND MARKED "" A"" ON PAGES OF THE PLANS THAT ARE AFFECTED(((((((New 6 story 82 unit apartment building using old codes. Building approved in 2013."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5697	18041-20000-37608	9410 N DE SOTO AVE Unit-J,K,L,M	91311	12	198B109    75	2748002068	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	34.24147	-118.58834	Plan check for Title 24 Energy only for fire damage existing commercial building Unit J, K,L,M. Total area: 8697 sq ft. Note: Building permit has been  issued under 17016-20000-04534	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5698	10041-10000-23341	5771 W 96TH ST	90045	11	093B169   134	4125021010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	12/27/2010 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	33.94955	-118.38342	New manufacture. New panel and circuits. EPC is for power and energy. (BLG# 5771)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5699	19041-10000-31814	127 S PECAN ST	90033	14	129A219   192	5172002911	OS-1XL-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.04655	-118.22203	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5700	14041-10000-07247	5757 W WILSHIRE BLVD #559	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.06259	-118.35341	TI IN AN EXISTING DENTAL OFFICE. EPC IS FOR T24 & EMERGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5701	14041-20000-24089	6501 N FULTON AVE	91401	2	180B157   719	2329025017	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Apartment			09/03/2014 12:00:00 AM			PC Info Complete	09/17/2014 12:00:00 AM	ADDRESS	34.18853	-118.42274	REPLACE FIRE DAMAGED SERVICE EQUIPMENTTHIS PLAN CHECK IS FOR SERVICE ONLY. NO LOADS OR CIRCUITS AT THIS TIME. ALL LOADS ARE FOR PROJECTED (FUTURE) LOADSCOMPLY WITHDEPARTMENT ORDER effective date 12/31/2013. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5702	16041-20000-24324	3650 E OLYMPIC BLVD 3rd Floor	90023	14	118-5A227 227	5191024011	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Issued	02/01/2017 12:00:00 AM	ADDRESS	34.01861	-118.1992	"Plan check Title 24 only in existing building T.I. 3rd floor. Total area: 24,711  sq ft.  ""COMPLY WITH DEPARTMENT ORDER effective date 04/21/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5703	18041-30000-10942	10130 W RIVERSIDE DR	91602	4	165B181    84	2424009038	[Q]C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.15196	-118.35181	Plan check for Title 24 only in existing retail store LED retrofit all existing house. no new wiring modification in place. Total area:8000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5704	14041-20000-27550	9338 N FARRALONE AVE	91311	12	198B101   217	2727018014	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.24012	-118.60987	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.2kW.(1) ABB PVI-3.0-OUTD-S-US-Z-A transformerless inverter(1) ABB PVI-3.0-OUTD-S-US-Z-A transformerless inverter(40) Kyocera KD255GX-LFB3 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5705	19041-20002-35746	23251 W KESWICK ST	91304	12	189B093   739	2027037005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM			PC Approved	10/23/2019 12:00:00 AM	ADDRESS	34.21033	-118.63408	10/23/19CHANGES TO APPROVED SET CHANGES TO BREAKER SIZE AND LOAD.<<<PV1.  Install 12.285 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (39) modules with 11.4 kW rated string inverter.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5706	16041-20000-05136	22601 W SANTA SUSANA PASS ROAD	91311	12	210B101    11	2723002018	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.27227	-118.6163	PLANCHECK FOR POWER ONLY.  UPGRADE DISTRIBUTION BOARD TO 1000 AMPS.( ON THE SAME PLAN AS 16041-20000-05132 SOLAR )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5707	19041-20000-13845	10700 N FULLBRIGHT AVE	91311	12	207B113    87	2707004019	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.26478	-118.57685	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 13.02KW DC/10.08KW AC. SCOPE OF WORK INCLUDES (42) MISSION SOLAR 310W PV MODULES AND (42) ENPHASE IQ7 MICRO INVERTERS AND A IQ COMBINER 3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5708	15041-20000-36591	5757 W WILSHIRE BLVD Suite 937	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	01/09/2016 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 only. Project site is a tenant space within an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 5,721 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5709	18041-10000-07046	9421 N WINNETKA AVE	91311	12	198B113    92	2748038028	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.2415	-118.57129	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 12675 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5710	17041-20001-03101	3397 N BARHAM BLVD	90068	4	159B181   187	5579007022	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.1333	-118.34402	11/29/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. MSP bus rating has increased to 1,000 amps. No other changes have been made.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. new three story commerial building 800 amp service.  building permit # 14010-20000-01950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5711	13041-20000-30665	315 W 9TH ST #600	90014	14	127-5A209 141	5144018049	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM			PC Approved	11/01/2013 12:00:00 AM	PIN	34.04341508	-118.25728547	change to lighting in an existing low-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5712	11041-10000-06031	6320 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	04/11/2011 12:00:00 AM	ADDRESS	34.18499	-118.59722	TI, T-24 ONLY, OTC PLAN CHECK.  SCOPE OF WORK IS ON 3RD AND 5TH FLOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5713	13041-10000-13799	12800 W HALKIRK ST	91604	2	162B161   363	2384006009	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.14181	-118.41173	PV1 6.75kw MICROINV 1 STORY HOUSE. STD. ROOFMOUNT.[ 27 MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: TRINA TSM-250Pa05}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5714	10041-10000-23501	4500 W LOS FELIZ BLVD	90027	4	150B197    26	5590003002	C4-1D, R3-1, RD1.5-1XL	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Finaled	06/28/2011 12:00:00 AM	ADDRESS	34.11156	-118.28786	CHANGE OF USE PART OF EXISTING RESTAURANT TO BANK OFFICE ON THE FIRST FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5715	17041-20000-17008	2929 N NORTH MAIN ST	90031	1	136-5A223 427	5210017020	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.06619	-118.2105	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from retail to manufacturing. Total lighting area = 3,828 sq. ft.Note: Building permit has been issued under 16014-10000-04310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5716	14041-20001-08331	6673 N BOBBYBOYAR AVE	91307	12	180B093   224	2036003012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.19186	-118.63272	PV1.  Install 7.5 kW roof-mounted PV system, connect with main service panel.  Transformerless inverter: SE6000A-US-ZB-U with power optimizers.  30 modules: Canadian Solar CS6P-250PX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5717	18041-10001-41457	21100 S WESTERN AVE	90501	15	054B193   598	7349002035	M1-1VL, P-1VL, RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	33.83941	-118.30903	REVISION TO AN APPROVED SET UPSIZING OF AHU-1 AND AHU-2 , CHANGE UNDER DELTA 1, SHEET E4.1. ORIGINAL SCOPE: PC FOR POWER ONLY, 2 ROOF TOP AHU, 2 INLINE PUMPS, AND 2 FLUID COOLER PUMPS REPLACE 1 FLUID COOLER FAN, REMOVE 2 COMPRESSORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5718	10041-20000-25681	2340 W PICO BLVD	90006	1	129B197  1086	5056004021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Closed	03/18/2011 12:00:00 AM	ADDRESS	34.04707	-118.28767	New roof mounted Hybrid P.V. system on commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5719	13041-10000-07436	6374 W SUNSET BLVD SUITE B	90028	13	147A187   590	5546015043	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.09768	-118.32839	Full plan check for power and energy for first time tenant sushi restaurant. 3529 sqrft. 250A load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5720	13041-10000-30871	15822 W CHATSWORTH ST	91344	12	207B141   422	2668001016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.26442	-118.47705	PV1, Install5.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 21 modules Yingli Yl245P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5721	16041-10000-29891	1707 N RAVENNA AVE	90744	15	036B205   130	7421002021	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	33.79753	-118.26943	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(24)MODULES-LG320N1C-G4(24)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE7600A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5722	12041-10000-29878	770 S GRAND AVE	90014	9	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Expired	03/17/2015 12:00:00 AM	ADDRESS	34.04594	-118.25757	New methane detection system for the first floor of a high rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5723	17041-20000-15368	17220 W SILVER LANE	91316	5	174B133   717	2258001053	RE11-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/03/2017 12:00:00 AM	PIN	34.17065577	-118.50849667	install roof mounted pv system sized 7.2kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5724	18041-10000-45902	7831 S SEPULVEDA BLVD	90045	11	099B165   141	4109002033	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.97046	-118.39548	REMOVE OUTDOOR EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5725	15041-20000-14097	6239 W FOOTHILL BLVD	91214	7	198B205   194	2571006024	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	PIN	34.24137572	-118.26693145	Plan check for Title 24 only for outside lighting. Circuit pulling from 6239 Foothill to illuminate the canopy. Total area: 3,000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5726	13041-20000-33915	7455 N LANKERSHIM BLVD SUITE E	91605	2	186B169   486	2317010024	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.20625	-118.38798	PC FOR T24 ENERGY ONLY. EXISTING LAUNDRY MAT. NEW LIGHTING. PERMIT ALREADY ISSUED UNDER APPLICATIONS :13041-20000-32495)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5727	19041-10000-31806	11300 S HINDRY AVE	90045	11	087B173   124	4129038020	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	33.93165	-118.37222	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5728	19041-10000-08673	752 S SAN PEDRO ST	90014	14	126A211   253	5146026011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.03931	-118.24794	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5729	19041-20000-07795	24347 W STONE BEND LANE	91304	12	192B089   177	2017038009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.22022	-118.65571	PLAN CHECK FOR NEW ROOF MOUNTED 2.835KW DC/3KW AC PV SYSTEM, SCOPE OF WORK INCLUDES 9 SC315B2 PV MODULES, AND 1 SE3000H INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5730	15041-20000-26643	221 N FIGUEROA ST 2nd floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check Title  24 only for existing office space. Total indoor area: 850sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5731	15041-20000-32039	8618 N MELVIN AVE	91324	12	195B117   371	2783017014	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.22692	-118.55984	PV1 SFD TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM. USING 30 MODULES IN TOTAL. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5732	13041-10001-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	Change to approved set by relocating distribution panels, and increasing the size of feeder conductor.(((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5733	17041-10001-39398	189 S THE GROVE DR Q10-A	90036	4	138B177  1132	5512003042	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR CHANGES TO APPROVED SET TO REFLECT LIGHTING CHANGES. SCOPE INCLUDES CHANGES TO FIXTURES AND REVISION TO T-24 FORMS. THIS IS PLAN CHECK ONLY!PERMIT UNDER MASTER. T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN AN EXISTING MERCANTILE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 598 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5734	16041-20003-40556	338 N PATTON ST	90026	1	135A209    20	5160009003	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			04/10/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.06615	-118.25849	04-10-2019 Changes to an permitted set of plan, changes include revised elevator size to 15 HP. All Changes has been clouded. Plan check only, permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5735	16041-10000-45690	9719 S MAIN ST	90003	8	093A203   293	6053014013	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	33.9476	-118.27403	PC for energy only to an existing charter middle school. TI, create 3 new offces within an existing classroom space. Total affected area: 2052.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5736	12041-10000-29523	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			12/07/2012 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.02174	-118.39786	INSTALLATION OF NEW FIRE ALARM SYSTEM IN AN APARTMENT BUILDING WITH 7 PANELS AND 615 DEVICES. FIRE DEPARTMENT HAS NOT APPROVED THE PLANS AT THE TIME OF SUBMITTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5737	11041-10000-11535	10950 W PALMS BLVD 1-10	90034	11	120B161  1306	4252017036	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.02	Electrical	Electrical	Apartment			06/06/2011 12:00:00 AM	06/06/2011 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.02117	-118.41798	NEW FIRE ALARM SYSTEM FOR NEW 4-STORY, 10 UNIT, APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5738	14041-10000-02067	1000 S SAN PEDRO ST	90021	14	124-5A211 149	5132011022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.03569	-118.25164	Plan check for energy and power. Total area is 4890 sq ft. Commercial building. 600 amp New service. 4 new panel under 200 amp. Building application: 13016-10000-24505	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5739	19041-20000-19999	1120 W 6TH ST STE 105	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	34.05418	-118.26297	First time tenant for restaurant space in mixed use building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5740	14041-20000-06841	17816 W SIDWELL ST	91344	12	219B129   669	2601071025	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.30029	-118.52223	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE  6.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5741	17041-10001-34701	1956 E 20TH ST	90058	14	118-5A215  82	5167006009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.0179	-118.23785	Supplemental for changes to approved set. All changes are clouded under delta 4 & 5. DWP required the amount of PV modules to be reduced from 512 modules to 248 (85.56kW(dc)) modules. Reducing from five strings to three strings with new output at 86.6kW(ac).Note: Permit is Paid under PCIS#17041-10000-34701	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5742	14041-20000-23320	10336 N WOODLEY AVE	91344	12	204B141   194	2668021013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.25867	-118.48465	PV1 SFD. TOTAL SYSTEM SIZE 8KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING STANDARD PLAN. TOTAL OF 34 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5743	15041-10000-18181	12903 W DESMOND ST	91331	7	216B161   484	2527005017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	PIN	34.28623013	-118.41360072	ROOF-MOUNTED PHOTOVOLTAIC SYSTEM  6KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5744	16041-10001-25354	6200 W WILSHIRE BLVD #1004	90048	5	135B177   512	5088015021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	34.06295	-118.36347	CHANGES TO APPROVED SET OF PLANS. THIS IS FULL PLAN CHECK FOR POWER WIRING SYSTEM. CHECKING FOR MEDICAL CLINIC ARTICLE 517. PROVIDING GROUNDING TYPE CONDUIT WITH ADDITIONAL GROUND WIRE FOR POWER WIRING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5745	10041-10000-23904	840 W DOWNEY WAY	90089	8	118-5A201  22	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	06/02/2011 12:00:00 AM	ADDRESS	34.01997	-118.28717	TENANT IMPROVEMENT IN LABORATORIES LJS AND OCW LOCATED ON LEVEL 1PLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5746	19041-10000-34773	5933 W CARLTON WAY	90028	13	148-5A191 222	5545005009	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.10057	-118.31906	pc for pv-1, system size is 3.990KW. 14 panels Hanwha Q-cell with 14 optimizers , 1-SE3800H-US inverter .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5747	19041-20000-16606	15314 W SUNSET BLVD	90272	11	129B125   545	4412002011	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	06/14/2021 12:00:00 AM		Permit Finaled	12/07/2021 12:00:00 AM	ADDRESS	34.04767	-118.52669	T.I to an existing commercial space.  Adding new lighting fixtures. Plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5748	15041-10000-22673	910 S ABBOT KINNEY BLVD	90291	11	109-5A143 472	4286013031	C2-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	33.99217	-118.47334	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING. ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 7787.PERMIT FEES PAID UNDER APPLICATIOB NUMBER 15041-30000-18092.THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5749	16041-10000-41651	13021 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	05/15/2017 12:00:00 AM		Issued	05/15/2017 12:00:00 AM	ADDRESS	34.18799	-118.41661	PC FOR TI TO RETAIL STORE. PC FOR POWER AND ENERGY. PROVIDING NEW SERVICE AND ALL NEW ELECTRICAL THROUGHOUT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5750	17041-10002-09019	1748 W CUMBRE DR	90732	15	012B189    24	7560028001	R1-1XL	Harbor	San Pedro	Coastal San Pedro, Northwest San Pedro	YES	2974.00	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Closed	06/15/2020 12:00:00 AM	ADDRESS	33.72945	-118.31623	PC  FOR changes to approved set under delta 2.Scope includes 14 new added devices per field inspection.All affected calculations have been reviced.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5751	19041-20000-37060	11211 N SEPULVEDA BLVD lot #17	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 4.09 KW ROOF MOUNTED PV SYSTEM WITH (13) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5752	15041-10000-10579	5655 W ADAMS BLVD	90016	10	123B173   812	5048003061	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2184.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.03262	-118.36664	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 4688 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5753	15041-20000-09977	211 S AVENUE 20	90031	1	138A221   176	5447024033	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	34.07213	-118.22001	Plan check for school T-24 only. Remodel school class rooms and add new fixtures, most fixtures remain same. Total area: 9000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5754	17041-20000-32467	9464 W BEVERLYCREST DR	90210	4	147B165   319	4352010024	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM			Verifications in Progress	05/31/2018 12:00:00 AM	ADDRESS	34.09849	-118.40345	Addition to (E) 2-story SFD.  New 600 A 120/240V service.  Plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5755	15041-10000-33032	20790 W NORDHOFF ST Bldg 2-#5	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	T-24, CHANGE OF USE TO RESTAURANT IN AN (E) BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1315.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5756	16041-20000-10832	4451 N STERN AVE	91423	4	165B153   130	2271011018	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.15177	-118.43563	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.36 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5757	13041-20000-34445	1135 W 71ST ST	90044	8	102B197   930	6014030025	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	33.97552	-118.29486	New Enphase PV system on the roof of an existing sfd.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5758	13041-20000-20854	18240 W ACRE ST	91325	12	195B125   737	2769021028	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.22986	-118.53091	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.886 KW. USING TRANSFORMERLESS INVERTER. 18 MODULES. 1 CENTRAL INVERTER. 3 STRINGS FOR 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5759	16041-10000-16720	5245 W CENTINELA AVE	90045	11	102B173   831	4102001028	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	33.97884	-118.37165	TI on (E) Grocery Store (Ralphs), adding new Starbucks.  New connected load > 400A. Relocate 64 lights. (alteration under 10% of existing light).B# 16016-10000-01399	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5760	18041-20000-37316	20663 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.29288	-118.58451	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5761	18041-20001-44435	5401 N SEPULVEDA BLVD 1-46	91411	4	172-5A145  22	2250001020	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	34.16854	-118.46653	Expedite fee.PV2.  Install 53.95 kW roof mounted grid tied PV system.  (166) modules with (4) 11.4 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5762	16041-10000-17138	1840 S CENTURY PARK EAST 1ST FLOOR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	T-24, PC FOR ENERGY ONLY. INTERIOR OFFICE TI. TOTAL AFFECTED AREA IS 1440 SQ. FT. B# 16016-10000-10189.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5763	16041-10000-02047	1126 W 75TH ST	90044	8	102B197  1685	6019014007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	33.97175	-118.29494	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.6KWac. (20)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB#PVI-3.6-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5764	17041-10002-34464	211 S AVENUE 20	90031	1	138A221   176	5447024033	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.07213	-118.22001	PC FOR A LOST SET OF PLANS.NOTE: PERMIT IS PAID UNDER APPLICATION 17041-10001-34464____________________________________________________________________________CHANGES TO APPROVED SET. ALL CHANGES ARE CLOUDED UNDER DELTA 3.SCOPE INCLUDES REVISING SINGLE LINE DIAGRAM, REMOVING/RELOCATING INVERTERS, RELOCATING MODULES, AND ADDING 54 MODULES. NEW SYSTEM SIZE  87.8KW DC /66.6KW ACTOTAL # OF MODULES 234 TOTAL # OF INVERTER 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5765	19041-10000-40279	14830 W SEPTO ST	91345	7	201B149   129	2647010027	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	10/26/2019 12:00:00 AM	ADDRESS	34.25079	-118.45545	PV plan check for single family residential. system size 6.20KW-DC and 5.66KW-AC. system consits of 20 candaian solar modulels with p320 optimizers. (1) SE6000 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5766	14041-20000-17116	10526 W DUBNOFF WAY BLDG A	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.18656	-118.36106	"T.I. for classrooms of Building A.  Install branch circuits and lighting.  Plan check for power and energy.Note: Applicant will submit approved plans within 3 days.  See ""Application Comment"" for more info."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5767	14041-20000-22559	18208 W HERBOLD ST	91325	12	201B125   392	2764017063	RE9-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.24491	-118.52992	pv1 single family. 8.4 kw AC using 2 transformerless inverters nonstandard plan. 26 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5768	13041-20000-28897	16454 W KNOLLWOOD DR	91344	12	219B137    75	2609016004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.29655	-118.49563	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 11.73. 46 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5769	17041-20000-18071	22950 W VANOWEN ST d	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.19343	-118.62746	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5770	18041-20000-18410	14834 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.2949	-118.45426	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.87kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5771	15041-20000-19928	5900 W WILSHIRE BLVD 1st & 2nd-Floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for Title 24 only. Project site is an existing commercial building; building is the East Satellite Building. Project scope is a tenant improvement. Total lighting area = 12,826 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5772	16041-30000-44120	6101 N SHIRLEY AVE	91356	3	177B117   512	2153028032	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Issued	01/05/2017 12:00:00 AM	ADDRESS	34.18105	-118.55804	Plan check for a Pv1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverter, (35) modules, (1) load center, and (1) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5773	10041-10000-23510	501 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Closed	05/17/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY  ( 2-DAYS ) STANDBY GENERATOR  TO SUPPLY POWER TO EACH OF TWO MCC WHICH POWERS EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5774	16041-10000-06864	1218 W VENICE BLVD	90006	1	127-5A201 321	5135011020	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.04245	-118.28145	T-24, CHANGE OF USE PORTION OF WAREHOUSE TO TWO POULTRY MARKETS. SCOPE OF WORK INCLUDES NEW ELECTRICAL EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2345. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5775	15041-10001-16136	10667 N ILEX AVE	91331	7	207B157   673	2620004001	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.26379	-118.42147	EXPEDITED PV1(((PV 1 ROOF MOUNTED SOLAR SYSTEM. 12 MODULES AND 1 INVERTER. TOTAL SIZE: 3.8KW. SUBMITTED PER APPLICANTS REQUEST. (12) SUN POWER SPR327NE-WHT-D(1) ABB PV1-3.8)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5776	19041-10001-21756	241 E CENTURY BLVD #3	90003	8	091-5A205  81	6052016024	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	ADDRESS	33.94575	-118.27027	CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES THE ADDITION OF A SUBPANEL TO A PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5777	14041-20000-06677	545 S OLIVE ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.04835	-118.25412	New bakery with dining area in an existing building on first floor.  Install new branch circuits and lighting.  Plan check for power and energy.  Note: Building permit is under 14016-10000-03566.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5778	14041-20001-03562	17545 W ROSCOE BLVD	91325	12	192B129   285	2787016005	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.22118	-118.51658	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.3 KW AC USING ENPHASE MICROINVERTER M215. NONSTANDARD PLAN. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5779	19041-10001-51280	8108 S VERMONT AVE	90044	8	099B197  1065	6032005016	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	07/07/2020 12:00:00 AM	ADDRESS	33.96518	-118.29134	EXPEDITE FEESPV2, NEW ROOFTOP AND CANOPY MOUNTED PV SYSTEM, SYSTEM SIZE IS 50KWac/46.4KWdc. SCOPE OF WORK IS 116 MODULES (400w LG) WITH RAPID SHUT DOWN DEVICES (TIGO TS4-R-F), LEADING TO A CENTRAL INVERTER (SMA TRIPOWER STP 50-US-41), A NEW 53 KVA TRANSFORMER, TERMINATING IN SOLAR PV BREAKER, NOTE THERE IS A NEW 600A SERVICE, WHICH IS IN PLAN CHECK UNDER 19041-10000-47092.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5780	19041-10000-31763	415 N LOS ANGELES ST 1ST FLR	90012	14	132A215   110	5408008905	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM			PC Approved	11/01/2019 12:00:00 AM	ADDRESS	34.05553	-118.23933	T.I. FOR EXISTING MUSEUM (1ST FLOOR)- new feeder with xfmr/panelboard/new circuitsPLAN CHECK S FOR TITLE 24 AND 1 EA EMERGENCY CKTTOTAL AFFECTED AREA 1549	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5781	14041-20001-12038	12655 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/06/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.97753	-118.41457	((EXPEDITE FEES))pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #1. 1/3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5782	12041-10000-23967	3435 W WILSHIRE BLVD	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.06194	-118.29866	TI in the corridor area of a commercial Bldg.  (5th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5783	19041-30000-12168	3822 S CLARINGTON AVE	90232	5	120B165  1284	4207005024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.02194	-118.39971	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,735 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5784	13041-20003-35784	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	33.97749	-118.41246	UPDATE SITE PLAN TO INCLUDE DWP SPECIFIC NOTES. NO OTHER CHANGES INVOVLED. CHANGES ON SITE PLAN CLOUDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5785	11041-10000-05846	4417 S STAUNTON AVE	90058	9	112-5A213 135	5106004006	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM			PC Approved	04/05/2011 12:00:00 AM	ADDRESS	34.00334	-118.24214	T.I.  EXISTING STORE.  INSPECTOR REQUESTED PLAN CHECK.  LIGHT FIXTURE CHANGES.  TITLE 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5786	18041-10000-37062	9850 S LAUREL ST	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	33.94793	-118.23082	TI IN A NEW COMMERCIAL RETAIL STORE. (FEE ESTIMATE)PLAN CHECK FOR POWER AND ENERGY. 30,474 SQR FT.BLD PERMIT: 18010-10000-00187	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5787	13041-20000-35134	21555 W OXNARD ST	91367	3	177B105    33	2146005177	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.17943	-118.59939	T24 FOR BREAKROOMS IN HIGHRISE OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5788	19041-10000-24606	18408 W OXNARD ST BUILDING-3	91356	3	177B125   698	2157001147	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	07/15/2020 12:00:00 AM		Permit Closed	04/26/2022 12:00:00 AM	ADDRESS	34.17983	-118.53357	PC (ENERGY ONLY) FOR CORE & SHELL-CHANGE OF USE FROM WAREHOUSE/OFFICE TO OFFICE. AREA OF SCOPE 9,088SF.FOR OUTDOOR WORK IN BUILDING 3.INCLUDING ONE PANEL AND CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5789	19041-10000-45829	1016 S SANTEE ST STE 8	90015	14	126A209   230	5145020034	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.03849	-118.25526	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5790	15041-10001-34610	1205 E 6TH ST	90013	14	126A215   332	5164009012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			06/13/2016 12:00:00 AM			PC Info Complete	08/15/2016 12:00:00 AM	PIN	34.03841309	-118.23802517	PLAN CHECK FOR RENOVATION OF AFFORDABLE HOUSING BUILDING. ADDING MICROWAVE CIRCUIT TO EACH UNIT (58 NEW CIRCUITS TOTAL).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5791	13041-10000-26834	2030 S CENTURY PARK WEST	90025	5	132B161   715	4319004138	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	PIN	34.05620922	-118.41664926	PV2.  NEW ROOF MOUNTED PHOTOVOLTAIC SYSTEM. SYSTEM SIZE 93,600 kW DC. 82,469 AC. TRANSFORMER LESS INVERTER.  $0 PERMIT FEE DUE TO 2012 SENATE BILL 1222(312) ASTRONERGY CHSM6612P 300W MODULES(4) SNA SUNNY TRIPOWER 20000TL-US 20KW (480V)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5792	14041-20000-05631	4600 N WILLIS AVE	91403	4	168A149   149	2265001016	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.15426	-118.45511	PERMIT FEE $0.00 BY STATE SENATA BILL NO.1222New roof mounted PV system with 40.26KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5793	13041-10001-17637	12871 W RUNWAY ROAD Units 1-6	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/20/2015 12:00:00 AM			Corrections Issued	05/04/2015 12:00:00 AM	ADDRESS	33.97499	-118.41991	Changes to an approved set of plans. Changes include changes to a luminaire type and the addition of lighting controls to certain fixtures. *****Previous Work Description*****PLAN CHECK POWER AND ENERGY FOR NEW 6-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #3  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5794	10041-10000-25752	5533 W HOLLYWOOD BLVD	90028	4	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	ADDRESS	34.10188	-118.31038	Remodel existing residential building into a mixed use retai residential building.  Plan check is for electrical, and for common lighting and dwellling unit T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5795	16041-20000-44967	3340 S MOTOR AVE	90034	5	120B161    80	4314023016	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	08/22/2023 12:00:00 AM	ADDRESS	34.02863	-118.41004	Plan check for installation of a solar pv array, roof-mounted on a commercial building.Interconnect with a 400A MSP. 20kW (10+10) ungrounded system. (72) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5796	12041-10000-11797	10025 N CABANAS AVE	91042	2	201B205   143	2571010038	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Expired	06/17/2014 12:00:00 AM	ADDRESS	34.25028	-118.26894	Plan check new 8.4KW roof  mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5797	17041-10000-00956	6400 N FALLBROOK AVE	91307	12	180B097   546	2038038021	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.18667	-118.62311	FULL PC FOR POWER AND ENERGY TO A NEW RESTAURANT. 480/277V 600AMP SERVICE, SINGLE STORY BUILDING. TOTAL SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5798	13041-20000-00379	903 W 49TH ST	90037	9	111B197   858	5018012027	RD2-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	09/18/2013 12:00:00 AM	ADDRESS	33.99886	-118.28938	New 7.3kw rooftop mounted photovoltaic system for an existing single family residence.  System uses Micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5799	15041-10001-20844	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	7/14/15 Changes to an improve setnote: changes on delta 1 [Ref: 15041-10000-20844]((Installation of (N) fire alarm system to (E) commercial retail building.  122 device system with new fire alarm control panel.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5800	19041-10000-02025	12607 W HART ST	91605	2	183B161   485	2324023016	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.19768	-118.40765	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIALR ROOF-TOP. TOTAL SYSTEM SIZE IS 4.32KWdc / 3.0KWac.(12)MODULES-HYNDAI 360W HIS-S360RI(12)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5801	19041-20000-04197	20730 W PRAIRIE ST	91311	12	198B109    81	2748002048	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/04/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	11/04/2021 12:00:00 AM	ADDRESS	34.24073	-118.58534	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from manufacturing/office to warehouse/office. Total lighting area = 219,726 sq. ft.Note: Building permit has been issued under 19016-20000-03279	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5802	15041-20000-26141	3660 S COLONIAL AVE	90066	11	114B153   996	4246009005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Issued	08/20/2015 12:00:00 AM	ADDRESS	34.00668	-118.43694	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (26) modules, and (26) power optimizers. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5803	15041-20000-24701	22624 W MARGARITA DR	91364	3	165B097   195	2076014020	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.15079	-118.61913	Installation of new roof mounted solar PV array.  Total system size = 6.665 kWac.  Microinverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5804	15041-10000-38330	814 W 23RD ST FP	90007	1	123A203    94	5124029017	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.03246	-118.27812	NEW 600A FIRE PUMP SERVICE. NEW FIRE AND JOCKEY PUMP.NEW SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5805	19041-10000-28596	11430 W CHANDLER BLVD	91601	2	171B169   146	2350011901	OS-1XL	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.16788	-118.37982	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5806	12041-20000-00619	11100 W SANTA MONICA BLVD 17th Floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.04726	-118.44465	T.I. to existing high rise building on partial of 17th floor (conference, reception, office, and break areas).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5807	14041-10000-13691	6420 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.18748	-118.64249	T24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 1299 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5808	19041-10000-18038	13720 W RIVERSIDE DR	91423	4	168B157   318	2269025002	C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.15674	-118.43273	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5809	16041-20000-08947	17736 W COMMUNITY ST	91325	12	192B129   246	2787009015	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM			Reviewed by Supervisor	03/30/2016 12:00:00 AM	ADDRESS	34.22265	-118.52068	Plan check for a PV1 roof-mounted PV system. System size is 16.4 kWac and consists of (2) inverters, (70) modules, (1) load center, and (1) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5810	16041-20000-21789	10100 N OWENSMOUTH AVE	91311	12	204B105   624	2747012010	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.2538	-118.60154	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5811	13041-20000-14778	13267 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW. USING MICROINVERTER STANDARD PLAN ENPHASE M215. TOTAL OF 15 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5812	19041-20000-07277	3525 W 8TH ST	90005	10	132B193   572	5093011013	(T)(Q)C2-2D	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Issued	02/28/2019 12:00:00 AM	ADDRESS	34.05782	-118.30714	temp power for construction site 1000 amp serive.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5813	19041-20001-13858	11669 W SANTA MONICA BLVD	90025	11	126B149   234	4262002017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM			Corrections Issued	06/25/2019 12:00:00 AM	ADDRESS	34.04409	-118.45575	Revision to approved plans.  Additional distribution and loads; lighting detail changes.  (((ti to an existing medical building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5814	15041-10000-42276	3850 S HOBART BLVD	90062	8	117B193  1153	5036010005	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.01582	-118.30765	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING NONSTANDARD PLAN. TOTAL OF 24 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5815	19041-10000-45858	2060 N VERMONT AVE	90027	4	150B197   260	5590005038	R3-1XL	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.10951	-118.29163	PC FOR TITLE 24 ENERGY ONLY. NEW OUTDOOR LIGHTING. TOTAL AFFECTED AREA IS 24850 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5816	11041-20001-19890	2025 N RODNEY DR	90027	4	150B197   393	5590006017	R3-1XL	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Apartment			12/27/2011 12:00:00 AM			PC Approved	12/27/2011 12:00:00 AM	ADDRESS	34.10844	-118.28927	Modification to an approved set of plans.  The modification are the use of 70 amp breakers for the unit panels instead of 100 amp, using a 15 amp breaker for the general lighting instead of 20 amps, and using a #4 wire for some of the feeders for the unit panels instead of having them all be #2 wire.  <<<<<<New 23 unit apartment building.  Fire alarm will be subitted under a separate application.  A fire alarm variance is required.  Plan check is for energy and power.>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5817	14041-20000-09494	9027 N GLENOAKS BLVD	91352	6	195B173   128	2408032033	P-1, [T][Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM			Reviewed by Supervisor	05/08/2014 12:00:00 AM	ADDRESS	34.23291	-118.36996	PC FOR POWER ONLY. NEW 800A SERVICE HIGH LEG 240. SERVING EXISTING 400A SUBPANEL AND NEW STEP UP TRANSFORMER FOR NEW INJECTION MACHINE. NO OTHER LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5818	12041-10000-20207	334 S MAIN ST	90013	9	129A213   129	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	12/04/2012 12:00:00 AM	ADDRESS	34.04841	-118.24668	FIRST TIME TENANTS IN A NEW RESTAURANT IN SUITE # 1101A  ON THE FIRST FLOOR OF A FIVE STORY MIXED USED BUILDING. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5819	10041-10000-25386	1033 N COLE AVE	90038	4	144B185   841	5533014901	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Expired	05/17/2013 12:00:00 AM	ADDRESS	34.08983	-118.33006	INSTALLATION OF A 50KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5820	14041-10000-15986	1038 S WESTWOOD BLVD	90024	5	132B153    52	4363020009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Issued	06/16/2014 12:00:00 AM	ADDRESS	34.0618	-118.44516	INSTALLATION OF A NEW FIRE ALARM SYSTME. TENANT IMPROVEMENT FOR URBAN OUTFITTERS. 1 FACP AND 26 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5821	16041-20000-31001	21255 W BURBANK BLVD Bldg D-6th Floor	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.17432	-118.59446	Server room equipment and HVAC for (E) IT room.  Plan check for power - lighting existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5822	18041-20000-15184	10925 W HARTSOOK ST	91601	2	171B173   764	2419001024	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1255.01	Electrical	Electrical	Apartment			04/25/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.16365	-118.36887	Plan check for power and energy. Project site is a new 4-story, 42-unit apartment building. Work includes a 1,600-amp service and a total lighting area of 41,715 sq. ft.Note: Building application has been generated under 17010-20000-03808	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5823	16041-20001-39799	8065 N WEBB AVE	91605	6	189B169    98	2310008003	C2-1VL-CUGU, M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.21748	-118.38966	03/22/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the restroom receptacles and the panel schedule has been added.*****Previous Work Description*****ti to an existing commercial building adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 1726.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5824	14041-20000-16939	5525 N SEPULVEDA BLVD	91411	4	174B145   590	2250001035	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.17114	-118.46644	Tittle 24 plan check only on  2 stairway  of a commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5825	15041-20001-17417	12701 W VAN NUYS BLVD B-2	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.27621	-118.41056	[[7/29/15  CHANGES TO APPROVED. T24 PLANCHECK ONLY. CHANGES TO LAYOUT AND ADDITION OF SOME AREA AND FIXTURES.]]]Plan check for Title 24 only for PACOMIMA OFFICE BUILDING. Total area: 3193 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5826	17041-10000-04765	1132 N GLENDALE BLVD	90026	13	139-5A207 131	5404016022	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.07702	-118.26071	CHANGING OUT OLD FIXTURES FOR MORE ENERGY EFFICIENT. PC FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA IS 51975 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5827	14041-20000-25643	5058 N ESCOBEDO DR	91364	3	171B105   940	2167018015	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.16242	-118.59181	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.12kW.(13) EnPhase M250 microinverters(13) Suniva 270W Black	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5828	14041-10001-29985	2735 S FIGUEROA ST	90007	9	121-5A203 142	5123015016	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.02634	-118.27738	Changes to approved set.  Electrical distribuition system is going from 600 A distribution board with 3 subpanels to existing 400 A distribution board with 2 subpanels.  Relocation of one light and other minor changes.  Electrical equipment will be relocated to existing electrical room.*****Previous Work Description*****New Starbucks shop within an existing building (existing Del Taco; not first time tenant). Plan check for power and lighting. Indoor lighting area = 3,084 sq. ft. and outdoor lighting area = 2,450 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5829	14041-20000-31864	12717 W VENTURA BLVD	91604	2	165B161   990	2375021018	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.14492	-118.41048	Plan check for energy only. TI to existing laundromat. Install new receptacles and lighting (incl. emergency). 3,809sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5830	17041-10000-12684	525 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.05109	-118.25696	PC FOR NEW DISTRIBUTION EQUIPMENT TAKEN FROM EXISTING SERVICE TO POWER DC SYSTEM FOR FUTURE CELL COMMUNICATIONS. SCOPE OF THIS WORK INCLUDES NEW PANELS, TRANSFORMER, RECTIFIERS AND A BATTERY SYSTEM. EACH CELL CARRIER WILL BE FUTURE UNDER SEPARATE PERMITS.Note to inspector: Please Verify the Meter number of the existing main distribution 4000A to match with the plan to  determine existing load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5831	16041-20000-00706	221 N FIGUEROA ST 11th Floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for Title 24 only for Existing high-rise T.I. Total area: 17,383 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5832	17041-10000-28841	420 S SEPULVEDA BLVD 1-24	90049	5	135B145   408	4366032011	[Q]R3-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	Apartment			08/15/2017 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Expired	01/24/2023 12:00:00 AM	ADDRESS	34.06686	-118.46058	PC for power only for new 600 A service for service and panelboard upgrade project to existing 24 unti apartment.  Installing new 120/240 V 600A service with 24 new dwelling panels, 1 house panel and new circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5833	15041-10000-39812	633 W 5TH ST 38TH FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EM CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5834	13041-10000-36079	1800 E MARTIN LUTHER KING, JR BLVD	90058	9	115-5A215  23	5117019016	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	34.00965	-118.24068	PLAN CHECK FOR POWER AND ENERGY. (1) NEW INDUSTRIAL BUILDING (116,724 S.F.) AND MEZZANINE FOR 2 TENANTS. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 139,170 SQ FT ( INDOOR + OUTDOOR). NONE-METHANE ZONE. NEW 2000A, 277/480V, 3PH,4WIRE SERVICE. SHELL ONLY.NOTE: ADDRESS NOT INDICATED ON PLAN.building permit: 13010-10000-04517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5835	14041-10000-09784	22968 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	34.18624	-118.62736	T24 FOR EXISTING PHARMACY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5836	18041-10001-22007	7026 N TOPANGA CANYON BLVD	91303	3	183B101   272	2138002041	(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.19811	-118.60562	DELTA 1 CHANGES TO APPROVED PLANS. UPDATING NUMBER OF DEVICES PER LAFD.<<<<<<<INSTALL A NEW FIRE ALARM (SPRINKLER MONITORING) SYSTEM WITH 55 DEVICES IN THE BUILDING.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5837	14041-20000-03429	5720 N WALLIS LANE	91367	3	174B109   255	2151018030	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.17457	-118.58324	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 8.8KWAC. USING SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5838	17041-10000-29456	11400 N ILEX AVE	91340	7	213B153   158	2616018032	M1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.27705	-118.4353	REMOVE EXISTING (24) HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 66900 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5839	18041-10000-11660	8829 W NATIONAL BLVD	90034	10	123B169  1385	4312015005	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.02913	-118.3864	PC for power and energy for Core and Shell for change of use from warehouse to office with interior parking garage. Installing new panelboards, new transformers, lights, receptacles and equipment. Total affected area is 26320 Sq. Ft.   B#18014-10000-01702.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5840	12041-20002-20994	18425 W KITTRIDGE ST	91335	3	180B125   375	2125015003	(T)(Q)R3-1LD	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Apartment			05/07/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.19033	-118.53458	((CHANGE TO APPROVED SET OF PLANS. NO CHANGE IN SERIES RATING COMBINATION. PC TO REVERIFY SERIES RATING COMBINATION TO SHOW NEW BREAKER LOCATION))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5841	19041-10000-01689	6340 W DREXEL AVE	90048	5	135B177   148	5510009026	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.06863	-118.36588	$0 FEE DUE TO AB1414 PC FOR ROOF MOUNTED 11.4 KVA PV SYSTEM. SYSTEM CONSITS OF 2 CENTRAL INVERTERS(SE3000H-US & SE7600H-US) WITH 35 MODULES USING P400 OPTIMIZERS  INCLUDING  2 ENERGY STORAGE SYSTEMS LG 9G CHEM 9.8KWH. 1 LOAD CENTER, AND AUTO TRANSFORMER, WITH RELOCATION OF LOADS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5842	12041-10000-26897	11575 N VIMY ROAD	91344	12	213B129   159	2601037038	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.2812	-118.52323	8.16 kw roof mounted PV for a single family using x-formerless INV. (PV-1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5843	15041-20002-04586	20131 W PRAIRIE ST	91311	12	198B113   121	2748038033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.2394	-118.57264	12/16/15Changes to an approve set of plans. All changes made under delta 7.  Scope includes adding new car charge stations, new track lights, and an inverter for emergency egress lighting.[[06-05-15 Change to  approve set of plan. Changes include addition of panel P1 to the MSB for car chargers]][[[[[TI TO AN EXSTING OFFICE COMMERCIAL BUILDING.  NEW STANDBY EQUIPMENT, PANELS, TRANSFORMERS AND CIRCUITS.  SCOPE OF WORK TO BE PERFORMED IN FIRST SECOND AND THIRD FLOOR.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 32225.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5844	14041-20001-05638	12810 N MEADOWLARK AVE	91344	12	222B133   451	2602009003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			Reviewed by Supervisor	03/18/2014 12:00:00 AM	ADDRESS	34.30331	-118.50857	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.0KWAC. 3 STRINGS 1 INVERTER WITH STRING COMBINER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5845	16041-10000-41439	8336 S LINCOLN BLVD	90045	11	096B157   258	4113016019	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	33.96186	-118.42076	PC FOR T24 FOR RESTUARANT TI WITH 1009 SQFT. INSTALLING NEW LIGHTS AND RECEPTACLES.*CHANGE OF USE FROM (E) RETAIL TO RESTAURANT. CHANGE OF USE DOES NOT ALTER PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5846	13041-10000-17515	20050 S VERMONT AVE	90502	15	057B197   154	7351033062	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	33.84838	-118.29024	PLAN CHECK FOR FIRE ALARM IN A CHURCH.  96 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5847	19041-10000-32302	1625 E PACIFIC COAST HWY	90744	15	036B213   404	7426033030	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	33.79134	-118.24314	REPLACE INDOOR/OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5848	16041-10001-35657	836 W 30TH ST	90731	15	009B197  1349	7469010009	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Apartment			10/07/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	33.71751	-118.29663	Expedite fees only.         Installation of new roof mounted solar PV array on existing 3 unit apartment building.  Total system size = 3 kWac.  Central inverter with new AC load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5849	17041-20000-38942	22769 W DEL VALLE ST	91364	3	171B097   499	2040031062	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Apartment			10/27/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Issued	10/27/2017 12:00:00 AM	ADDRESS	34.16551	-118.62275	New fire alarm system for 22-unit 4-story apartment building.  72 devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5850	10041-10000-16641	865 S FIGUEROA ST 25TH FL	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.04653	-118.26275	REMODELING OF OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5851	19041-20000-01652	11766 W WILSHIRE BLVD 1150	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.04804	-118.46227	PLAN CHECK FOR TITLE 24 FOR AN OFFICE SCOPE INCLUDES 2171 SQFT. BLD# 19016-30000-00212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5852	11041-10000-03319	12129 W MAGNOLIA BLVD	91607	5	171B165   461	2347018015	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.01	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.16502	-118.39755	conver retail space to mini market; new service and alterations	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5853	19041-30000-11911	601 S FIGUEROA ST 39th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is the 39th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 18,630 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5854	15041-10001-14364	3321 W 63RD ST	90043	8	105B185   799	4006003035	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	33.98304	-118.33025	CHANGES TO AN APPROVED SET, CHANGES ARE NOTED IN DELTA 2. CHANGES INCLUDE THE ADDITION OF A NEW LOAD CENTER. (((PV1 4.2KW AC roof mounted system; scope includes (11) SunPower SPR-327 modules and (1) Power One PVI-4.2-TL inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5855	12041-10001-04777	9301 N TAMPA AVE # 59A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			Corrections Issued	04/19/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T.I. FOR COSMETIC SHOP SUITE #59A IN AN EXISTING SHOPPING MALL.(((((((((((((((((  calculation and number of lights revised. 4-19-12 m.z)))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5856	17041-10000-07094	1746 N NORTH SPRING ST	90012	1	136-5A219  33	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.07002	-118.22561	Plan check for Title 24 only in existing space T.I. outdodor dining and indoor T.I. Total load is less than 400A . Total area: 3523 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5857	12041-20000-29403	17323 W VENTURA BLVD	91316	5	171B133   685	2257016056	(Q)C4-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	34.16115	-118.51065	Install new standby generator and associated equipment to supply existing distribution board.  Modify existing service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5858	16041-10000-13059	4110 W 3RD ST	90020	10	135B193   217	5503007010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			Verifications in Progress	11/01/2016 12:00:00 AM	ADDRESS	34.06877	-118.30336	PC FOR POWER AND ENERGY. NEW 5-STORY HOTEL OVER UNDER-GROUND PARKING, (172 ROOMS)  800A SERVICE. TOTAL AREA (INDOOR AND OUTDOOR) 100866 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5859	18041-10000-48205	10630 N SEPULVEDA BLVD	91345	7	207B145   393	2649011043	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.26357	-118.46694	Install New rooftop solar system on a commercial building. System size 40 kW AC / 41.745 kW DC.  (2) 20 kW central inverters, (121)  modules, (61) P730 optimizers, (2) 30 kVA transformers. (E) MSP is 600A, 240/120V, 3ph, 4W$0 inspection fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5860	19041-10000-49580	9853 N AURA AVE	91324	12	201B117   133	2761010050	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.24965	-118.55459	PC for PV-1 system, system size 10.560KW, 33 Modules With 320 optimiziers, 1 solaredge SE7600-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5861	12041-10000-22419	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.05979	-118.41671	REMODELING OF OFFICE SPACEON THE 12TH FLOOR PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT. PERMIT FOR NEW BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5862	17041-10000-06273	21001 W NORDHOFF ST	91311	12	198B109   170	2746009045	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.23562	-118.59125	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  49300 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5863	17041-20000-16371	312 E 1ST ST	90012	14	130-5A213 169	5161017035	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.0501	-118.24075	Plan check for fire alarm system. New fire alarm system for existing commercial building (core & shell TI). 1 FACP. 130 Devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5864	16041-10000-22238	507 S MAPLE AVE	90013	14	127-5A213  55	5148018027	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.0453	-118.24692	Full plan check to existing 55-unit apartment/hotel building. Existing 800 A main switchboard, Newly connected load is greater than 400 amps. Replacing one for one lights inside all units. Installing new lighting throughout common areas and corridors. Total sqft = 6901	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5865	10041-20000-16244	9301 N TAMPA AVE #42	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	ADDRESS	34.2392	-118.55379	"Energy plan check space # 42  ""OLD NAVY"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5866	15041-10000-02568	15927 W VENTURA BLVD	91436	5	168B141   544	2261021007	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.15615	-118.48017	INSPECTOR TO HAVE APPLICANT SUBMIT FO FULL PLAN CHECK DUE TO ASSEMBLY OCCUPANCY. 93.206ALTERATIONS IN EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5867	16041-20000-00123	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.97615	-118.42138	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENTS FOR OFFICE BUILDING, GROUND FLOOR AND MEZZANINE.Note: Building application has been submitted under 15016-10000-25133	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5868	19041-10000-07932	6036 N HAZELTINE AVE	91401	2	177B153   794	2239015032	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	34.18046	-118.43982	REMOVE INDOOR HID FIXTURES REPLACING WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5869	18041-10000-30137	8810 N TAMPA AVE	91324	12	195B121   511	2784003069	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.23097	-118.55317	REPLACING AN EXISTING FIRE ALARM SYSTEM WITH A NEW ONE WITH 253 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5870	11041-20002-21845	8746 N CANBY AVE	91325	12	195B125   699	2769025023	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM			PC Approved	05/11/2015 12:00:00 AM	ADDRESS	34.23002	-118.53466	Change to approved set by removing a connected panel and some load;  new load also added (mainly include 3-circuits and 3-nondwelling equipment) .  Note all changes are under delta-3 only.(((Existing building.  Building used to be a private school and is being converted to a rescue mission.  New switchboard, panels, lighting, etc.  Plan check is for energy and power.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5871	10041-20000-25690	614 W 35TH PL FL 1-8	90089	8	118-5A201   5	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Closed	08/04/2011 12:00:00 AM	ADDRESS	34.01998	-118.28258	Plan check T-24 Energy for restroom TI from floors 1-8 at USC Pardee Tower	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5872	18041-10000-34727	519 S GAFFEY ST	90731	15	015B197   184	7451030034	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	ADDRESS	33.73932	-118.2925	PLAN CHECK FOR TITLE 24 ONLY FOR - PROPOSED TENANT IMPROVEMENT TO RELOCATE AND UPGRADE RESTROOM; NO CHANGE IN USE OF OCCUPANCY - TOTAL AFFECTED AREA = 1388 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5873	17041-30000-01792	801 S FIGUEROA ST 7TH FL	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Title 24 plan check.  T.I. to 7th floor of existing commercial office highrise.  New lighting and receptacles supplied by existing subpanels.Building permit number 16016-10000-30782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5874	18041-10000-30191	8527 N VENTURA CANYON AVE	91402	6	192B157   276	2637021001	RD5-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.22515	-118.43161	NEW ROOF MOUNTED 3960 W(DC) PV SYSTEM WITH 11 PV MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5875	11041-10001-20657	1411-1417 S ELKGROVE CIR BLDG 9	90291	11	111B149   609	4243002070	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.0008	-118.4583	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5876	11041-20000-07891	127 S SAN VICENTE BLVD Bulletin-28	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 28   plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5877	15041-10000-37959	1131 S SWALL DR	90035	5	132B169   617	4332011034	R2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.05629	-118.38581	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(25) KYOCERA MODULES (1) ABB PVI-6000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5878	19041-10000-32273	11200 S HINDRY AVE	90045	11	087B173    86	4129038015	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	33.93291	-118.37221	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5879	17041-10000-00608	1000 W ELYSIAN PARK AVE Level 5	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.07196	-118.24719	Plan check Title 24 only in existing space 5th floor T.I Doger Stadium. Total area: 545 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5880	15041-10000-40533	1522 S WESTGATE AVE (1-9)	90025	11	126B149   563	4262005027	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.04171	-118.45842	Plan check for a fire alarm system for a new 3-story 9-units apartment building. Scope includes (1) fire alarm panel, (2) communication panel and (41) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5881	17041-10000-08656	9151 N MASON AVE	91311	12	198B109   140	2748001038	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.23711	-118.58066	PC for energy only, outdoor. Replacing HID fixtures with new LED ones. Area: 147,385.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5882	15041-20002-14538	4124 N STANSBURY AVE	91423	4	165B153   976	2266026010	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.14515	-118.44095	Changes to approved set.  Relocation of solar load center, change in load center busbar rating, and increase in wire size between load center and MSP.*****     PV1. Install roof mounted PV system sized 24.7 kW. Interconnected with main service panel.  q  (115) Yingli YL250-P Modules(115) Enphase M215 Inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5883	14041-20000-27121	15936 W LONDELIUS ST	91343	12	195B141   659	2672031008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.22924	-118.47968	PV1Install roof-mounted solar array on SFD. System size: 3.87kW.(18) EnPhase M215-IG microinverters(18) SolarWorld Poly SW 250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5884	15041-10000-14659	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Closed	02/12/2024 12:00:00 AM	ADDRESS	34.07587	-118.37754	REPLACING 4 PANELS (2) 800 AMP AND (2) 1600 AMP, LIKE FOR LIKE. CONNECTED LOAD TO REMAIN. PC FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5885	19041-10000-36779	12612 W CUMPSTON ST	91607	2	174B161   771	2346011065	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.16945	-118.40769	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800A-USS2) WITH 11 MODULES(LG LG365Q1C-V5) AND ESS (LG CHEM RESU 10H)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5886	18041-10002-13640	835 W JEFFERSON BLVD	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Info Complete	07/19/2018 12:00:00 AM	ADDRESS	34.02414	-118.28458	"DELTA 4 CHANGES TO THE APPROVED PLANS FOR RELOCATION OF PANELS AND TECHNOLOGY RACK ON THE FISR FLOOR BEHIND THE RESTROOM. <<<FULL PLAN CHECK (POWER + ENERGY) FOR 1ST TIME TENANT (AND ALSO CHANGE OF OCCUPANCY) FROM ""RESTAURANT"" TO ""RETAIL"", FOR ABERCROMBIE & FITCH. INSTALL (1) 225A PANEL WITH ITS CIRCUITRY, TOTAL AREA: 2,736 SQ.FT>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5887	11041-20000-01666	6110 N VARIEL AVE	91367	3	177B105    51	2149005034	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	09/14/2011 12:00:00 AM	ADDRESS	34.18136	-118.59257	energy plan check office	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5888	18041-20000-24997	3309 N ALGINET DR	91436	5	159B137   434	2287013046	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.13076	-118.49528	Plan check for PV roof mounted system, system size: 12.9kW AC CEC with 41 modules and 1 inverter(10kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5889	15041-20000-00011	2024 N CUMMINGS LANE	90027	4	151-5A195 180	5589009033	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2015 12:00:00 AM			Reviewed by Supervisor	02/06/2015 12:00:00 AM	ADDRESS	34.10793	-118.30124	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.8kW (48) SUNPOWER SPR E20(2) SMA SB6000TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5890	16041-20001-40256	432 S HARVARD BLVD	90020	10	135B193   546	5503010023	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	06/21/2017 12:00:00 AM	ADDRESS	34.06623	-118.30392	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 31.7kW (6kW*4+7.7kW) ungrounded system. (116) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5891	14041-10000-32699	20945 W PLUMMER ST STE #B	91311	12	201B109   343	2746007022	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.24286	-118.58984	Title 24 plan check only.  Total area = 6707 sq. ft.T.I. to two warhouse spaces (building #1 and building #2)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5892	12041-10000-13856	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	Wiring and equipment installation for end-use equipment to serve TBIT Gate nos. 151 and 153 and 155 and 157 and 159 consist of(10) PBB, (6) FGP, (6) AHU, and (6) PWC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5893	12041-10000-06318	1534 W PALOS VERDES DR NORTH BLDG K	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77931	-118.30463	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building K. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5894	13041-20000-34673	10220 N NORRIS AVE	91331	7	204B165   176	2537003048	(Q)M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.25576	-118.40122	existing offices. new expandion. new lighting. pc for t24 energy only. load less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5895	16041-20001-20465	2644 W PICO BLVD	90006	1	129B197  1127	5075007005	[Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.04704	-118.29597	Expedite per applicant request((((Plan check for PV roof mounted system. System size: 22kW with 72 modules and 2 inverters(11.0kW)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5896	12041-10000-27582	300 S GRAND AVE 3th floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	12/06/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	TI in an existing office. EPC is for T24 and emergency lighting. (3th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5897	15041-20000-18803	19950 W COLLIER ST	91364	3	171B113   574	2164005015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.16577	-118.56754	Plan check for PV roof mounted systm. System size: 6.0kW with 24 modules and 1 inveter(6.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5898	12041-10000-15750	3909 W OLYMPIC BLVD	90019	10	132B189  1243	5092016012	C2-1	Central	Wilshire	Greater Wilshire		2127.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.05371	-118.31989	REFERENCE # 11041-10001-03353 : CHANGES TO LIGHTING SYSTEMPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5899	16041-20000-31455	3716 S VETERAN AVE	90034	5	117B161   652	4252020048	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.01728	-118.41368	Plan check for a fire alarm system for an existing 4-unit apartment building. System consists of (1) FACP and (34) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5900	18041-10000-04538	2560 W OLYMPIC BLVD # 101B	90006	1	130-5A201 141	5076008030	(Q)C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.05219	-118.28707	FULL PC FOR POWER AND ENERGY,  MEDICAL OFFICE SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1770.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5901	13041-10000-31126	8831 W VENICE BLVD	90034	10	123B169  1196	4312008041	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.03083	-118.38619	title 24 out door lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5902	15041-20001-02079	9541 N AMESTOY AVE	91325	12	201B133   575	2692018025	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.24452	-118.50695	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 10.3KW AC USING 43 MICROINVERTERS. MODEL ENPHASE M250. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5903	10041-10000-24727	1600 W PALOS VERDES DR NORTH 1ST FLOOR	90732	15	030B193   203	7442001021	RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	33.7793	-118.30549	TI IN AN EXISTING COMMERCIAL AREA IN MARYMOUNT COLLEGE.  (UNIT #'S 1531 & 15383) ON THE 1ST FLOOR. PLAN CHECK IS FOR  T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5904	18041-20000-45783	8651 W FORSYTHE ST	91040	7	207B189   226	2555002047	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.26638	-118.3218	pv1install roof mounted pv system sized 9KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5905	14041-20000-03348	823 S MARIPOSA AVE	90005	10	132B197   604	5094018013	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			02/05/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.05705	-118.2989	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING ROOF MOUNTED SYSTEM. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5906	17041-10002-04642	20111 W RINALDI ST BLDG S6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.27542	-118.57218	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  25, & 26. CHANGES INCLUDE RELOCATING SITE/LANDSCAPE LIGHTING, ADDING LANDSCAPE LIGHTING, REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, REVISING PANEL SCHEDULES,  AND SPECIFYING EGC CONDUCTORS ON THE FLOOR PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5907	13041-10000-12060	380 WORLD WAY #T37-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check power and energy. First-time tenant in retail space at Tom Bradley Int'l Terminal at LAX (Emporio Armani). Space #T37-R	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5908	19041-10000-12433	6033 W CENTURY BLVD 8th floor	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			PC Approved	04/05/2019 12:00:00 AM	ADDRESS	33.94572	-118.38954	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE T.I. TOTAL EFFECTED AREA 1275 SQFT. INSPECTION FEES HAVE BEEN PAID UNDER ONLINE PERMIT 19041-90000-01028.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5909	19041-10000-10399	10923 W WEYBURN AVE	90024	5	135B149   586	4363018034	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	34.06274	-118.44623	PC Power and enegy for Resturant (change of use). Scope Area 2885SqFt	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5910	19041-20000-46489	14221 W CHANDLER BLVD	91401	4	171B153    96	2245024017	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.16872	-118.44272	PV1 PLAN CHECK FOR NEW PV SYSTEM, SYSTEM SIZE IS 12.24 KW DC/10.6 KW AC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH MICROINVERTERS AND A 125A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5911	16041-10000-03927	1311 E M ST	90744	15	033B213    44	7425019021	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	33.78944	-118.2475	PV1, INSTALL NEW 3.64 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE  FAMILY HOUSE.(14) MODULES: CANADIAN SOLAR CS6P-260P(1) INVERTER: FRONIOUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5912	19041-20000-27876	9845 N MASON AVE #102	91311	12	201B109   365	2748005056	(Q)CM-1LD, (Q)M1-1D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.24908	-118.58076	Plan check for first time tenant nail salon. Total area: 1359 sq ft B#19016-20000-22077	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5913	16041-10000-35865	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.21328	-118.45279	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO (E) MANUFACTURING BUILDING. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 10580 SQ. FT. B#15016-20000-00416	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5914	16041-10001-12009	8432 W MELROSE PL	90069	5	141B173   506	5528017033	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.08342	-118.37439	Changes to approved set: Removed Photosensors on some Daylight area, change under Delta-1.  This is Plan check only, master plan under 16041-20000-12009.<<PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR RETAIL. 2505 SQFT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5915	18041-10000-36942	2041 W BEVERLY BLVD UNIT B	90057	13	136-5A205 336	5157021001	C2-1	Central	Westlake	Echo Park		2084.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.06675	-118.27004	First time tenant in suite #B. Plan Check for Power & Energy (3388 Sqr Ft)Building Permit 18016-10000-23356Note. Portion of the permit fee is paid under 18041-10000-31961	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5916	19041-10000-52997	14300 W FOOTHILL BLVD	91342	7	228B149   603	2504006033	QRD3-1	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.31909	-118.44572	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5917	10041-10000-23533	134 S JAPANESE VILLAGE PLAZA MALL	90012	9	129A215    54	5161017033	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	ADDRESS	34.04881	-118.24046	"TENANT IMPROVEMENT AT ""DULCE"" REMODELING KITCHEN AREA AND CUSTOMER AREA, PLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5918	13041-20000-26718	12686 N COMETA AVE PV1	91340	7	219B157    38	2513015046	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	ADDRESS	34.30071	-118.42702	roof mounted photo voltaic (solar) system. 7.105 kw. TRANSFORMERLESS INVERTER. PC REQUIRED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5919	11041-20000-21529	12833 W LANDALE ST	91604	2	165B161    52	2362016008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	01/27/2012 12:00:00 AM	ADDRESS	34.15194	-118.41253	NEW 9.36 KW ROOF MOUNTED PV SYSTEM SINGLE FAMILY DWELLING.  MODULES MOUNTED ON HOUSE AND DETACHED GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5920	10041-40000-05991	1250 S EDRIS DR	90035	5	132A167   191	4330025004	RD1.5-1-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Apartment			04/02/2010 12:00:00 AM	04/02/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	ADDRESS	34.05583	-118.39785	Fire Alarm/central station monitoring system with pull station for apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5921	15041-10000-24925	5121 N SAN FERNANDO ROAD WEST bldg 24	90039	13	165B205   119	5593011043	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Issued	08/05/2015 12:00:00 AM	ADDRESS	34.1457	-118.27194	FIRE ALARM SYSTEM REPLACEMENT.  Hazardous location. Buildings 24 (H-3), 25 (mixed - H-2, H-3, F-2, B), 33 (F), and 34 (H-2, F, B).This permit covers building 24. Fees are under inspection. (2 of 4). See 150411000018030 for main plan check application.	N	N	Express Permit	06/10/2024 12:00:00 AM
5922	15041-10000-02018	2121 S AVENUE OF THE STARS 12th Floor	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.05554	-118.41342	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5923	19041-20000-17818	7472 W MELROSE AVE	90046	5	141B181   594	5526018024	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.08349	-118.35288	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5924	15041-20000-08233	10455 W MAGNOLIA BLVD	91601	4	171B177   637	2417017001	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	01/26/2016 12:00:00 AM	ADDRESS	34.16508	-118.35903	fire alarm systemNEW THREE STORY AND 26 UNIT APARTMENT BUILDING WITH 1 LEVEL SUB PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5925	17041-10000-29696	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.18684	-118.3977	PLAN CHECK FOR POWER AND ENERGY FOR (T.I. TO EXISTING (37,000 SF) RETAIL SPACE, INTERIOR ONLY). PLAN CHECK INCLUDES RELOCATION OF EXISTING 800A DISTRUBUTION EQUIPMEMT & NEW CONNECTED LOAD ~400A. TOTAL AFFECTED AREA 43,185 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5926	10041-20000-24815	3550 S TROUSDALE PKWY #237, 241-242	90089	8	118-5A201   9	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	07/25/2011 12:00:00 AM	ADDRESS	34.02094	-118.28463	Plan check T24 Energy (general/emergency) lighting for USC Edward Doheny Library TI room #237, 241, and 242.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5927	19041-30000-04329	3981 S MOORE ST	90066	11	111B153  1276	4236021026	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.99624	-118.4379	Plan check a fire alarm system for 4-story apartment building with a parking garage. Fire alarm consists of (1) FACP and (46) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5928	11041-10001-04611	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.23541	-118.47521	Plan check only. Revision to approved plans, Delta 5. Changes to lighting and power per as built condition. Plan check power and energy for new temple.  Plans checked under NEC 2005. Original plans approved and expired #08041-20000-08250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5929	16041-10000-24933	500 W 7TH ST	90014	14	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.04651	-118.25582	Plan check for Title 24 only for new installed lithting fixtures.  **Interior TI to inlcude new finishes and new equipements in sale area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5930	15041-20000-10047	12452 W OSPREY LANE #3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	Installation of new roof mounted solar PV array on 3 unit apartment building (triplex).  Each unit panel is fed by a seperate inverter (3 inverters total).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5931	13041-10001-12139	9301 N TAMPA AVE #218	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	CHANGES TO APPROVED SET. RELOCATED EQUIPMENT FOR KITCHEN, added 3 counter receptacles, moved bathroom receptacles to the counter, and moved transformer (suspended 225kva from electrical room to janitor closet and shall be �suitable for use in other spaces for environmental air� per applicant). (marked under Delta G2 9/16/13; HPK & Greenfield#2). Changes to panel schedule P.PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT TI- BONEFISH GRILL. SUITE #218	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5932	13041-20001-21586	4614 N MIRADOR PL	91356	3	168B121   470	2176032011	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.15412	-118.54778	((EXPEDITE FEES))PV1 10.92 KW NEGATIVELY GROUNDED SYSTEM. 42 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5933	17041-30001-07322	2005 S MAGNOLIA AVE	90007	1	126B197  1080	5056029005	[Q]R4-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM			PC Approved	03/14/2017 12:00:00 AM	ADDRESS	34.0379	-118.28736	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (36) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5934	10041-20000-12545	10790 W BELLAGIO ROAD	90077	5	141B149   245	4362007026	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2010 12:00:00 AM			PC Info Complete	07/22/2010 12:00:00 AM	ADDRESS	34.07951	-118.45244	New single family house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5935	10041-20000-09134	3601 S WATT WAY	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	01/04/2011 12:00:00 AM	ADDRESS	34.02113	-118.28752	Plan check mandatory measures to comply T-24 Energy. All lighting are existing to remain. USC Grace Ford Salvatori.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5936	13041-20000-24233	18937 W LABRADOR ST	91324	12	201B121   196	2762040010	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Expired	10/01/2015 12:00:00 AM	ADDRESS	34.24914	-118.54641	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING 22 MODULES. 2 STRINGS. TRANSFORMERLESSINVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5937	17041-10000-03975	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.05494	-118.23752	RESTAURANT TI TO BASEMENT AND 1ST FLOOR. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5938	18041-10000-36948	5418 W BEVERLY BLVD	90004	4	138B185   119	5515007002	A1-1XL-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	08/24/2021 12:00:00 AM	ADDRESS	34.07561	-118.32778	PLAN CHECK FOR METHANE SYSTEM CONSISTING OF 1 PANEL AND 25 DEVICES - SYSTEM INCLUDES 2 BUILDINGS UNDER 1 SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5939	14041-20000-34792	6629 N LEMP AVE 1-3	91606	2	180B169   464	2320025016	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Apartment			12/16/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Expired	02/14/2017 12:00:00 AM	ADDRESS	34.1912	-118.38487	PV2. INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (14) SUNPOWER SPR-327NE MODULUES (1) POWERONE PVI-4.2TL INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5940	14041-10000-04605	20750 W NORDHOFF ST Bldg 5	91311	3	198B109   193	2780001058	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.23522	-118.58548	PC for power and energy. BLDG 5. (2 of 4)building description 140410-10000-00412: NEW SPEC CONCRETE TILT UP INDUSTRIAL BUILDINGS; 1-STORY WITH MEZZANINE (BUILDING 5) OFFICE- 4,000 SQ.FT.; WAREHOUSE - 24,600 SQ.FT.HAVE APPLICANT VERIFY 20700 NORDHOFF ST. WITH B.O.E. ADDRESS COUNTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5941	12041-20000-18576	1518 S FEDERAL AVE 1-60	90025	11	126B149  1303	4261001029	C2-1VL, R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM			PC Approved	08/13/2012 12:00:00 AM	ADDRESS	34.04519	-118.45422	T.I. for a high rise building on the ground floor of the Gym.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5942	19041-10000-00227	2560 W OLYMPIC BLVD #100	90006	1	130-5A201 141	5076008030	(Q)C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	34.05219	-118.28707	INSTALL A NEW 600 AMP PANEL FOR FUTURE MEDICAL OFFICE AND RELOCATE EXISTING LOADS TO OTHER SECTIONS. No new load. BUILDING PERMIT: 18016-10000-36441	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5943	16041-20000-41739	515 S FLOWER ST 24th Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for energy only. TI to 24th floor office space in high rise building. New lighting (incl. emergency) and receptacles. 22,518sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5944	18041-20000-33303	16728 W KLEE ST	91343	12	195B137   541	2688031044	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.23098	-118.49717	PV1.  Install 8.45 kW roof mounted grid tied PV array.  (26) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5945	19041-10000-39024	10236 N ENCINO AVE	91325	12	204B129   203	2734026002	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.25671	-118.5153	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 8.8KVA PV1 SYSTEM CONSISTING OF 28 MODULES USING MICROINVERTERS(IQ7X) AND ESS(TESLA pOWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5946	10041-20000-04010	1600 N CAMPUS ROAD TRAILER 2	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	06/24/2010 12:00:00 AM	PIN	34.12750533	-118.21285206	TEMPORARY TRAILER  (TRAILER 1)  OCCIDENTAL COLLEGE, JAMES SWAN HALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5947	19041-10000-17888	1541 W WILSHIRE BLVD 2ND FLR	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Issued	05/22/2019 12:00:00 AM	ADDRESS	34.05529	-118.26949	PC for T24 only, scope of work is TI for interior offices.  Affected area is 2450 sqft. ((TENANT IMPROVEMENT OF (E) OFFICE))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5948	18041-10000-27436	7634 W WYNGATE ST	91042	7	204B197   583	2558007029	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM			Reviewed by Supervisor	07/30/2018 12:00:00 AM	ADDRESS	34.25735	-118.29909	NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL SENIOR LIVING FACILITY. SYSTEM CONSIST OF 128 MODULES (NEO SOLAR 355W) AND 6 INVERTERS  (GINLONG SOLIS 10KW, 4*7KW, 4KW) .  SYSTEM SIZE IS 45.5KWdc and 42KWac. SCOPE INCLUDES NEW 400 AMPS PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5949	18041-10000-25820	7614 N RUDNICK AVE	91304	3	186B101   126	2012020058	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.2088	-118.61194	Install new PV1 rooftop solar system, 6.900kW DC STC, 5.94 kW AC, (23) modules with (23) power optimizer, (1) 6.0 kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5950	19041-10000-08003	301-445 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	12/19/2022 12:00:00 AM	ADDRESS	33.77206	-118.27885	PERMIT FEE IS $0.00 DUE TO AB1414.PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 2718 MODULES (Q-PEAK 395), 1359 OPTIMIZERS (P850 ), 9 INVERTERS ( SE 99.9K), AND (2) SUBPANELS INTERCONNECTING TO AN EXISTING DEDICATED PV SOLAR SERVICE PANEL. SYSTEM SIZE IS 900KWac AND 1096KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5951	11041-10000-25442	217 E 8TH ST	90014	14	127-5A211 327	5145003005	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	34.04155	-118.25168	Additional, compatible,  4 - booster panels and 53 - fire alarm devices for an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5952	19041-20001-10066	545 W AVENUE 26	90065	1	142-5A219 112	5446011020	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM			PC Approved	04/30/2019 12:00:00 AM	ADDRESS	34.08494	-118.22345	Expedited plan check fee.PV3.  Install 18.84 kW roof mounted grid tied PV system.  (56) modules with (2) 7.6 and (1) 3.8 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5953	17041-10000-06465	660 S FIGUEROA ST 1720	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR ENERGY. TI TO AN EXISTING OFFICE BUILDING. HIGH RISE BULDING. TOTAL AREA 1719 SQ FT.B 16016-10000-29479	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5954	11041-20000-20580	15911 W ARMINTA ST	91406	6	189B141   146	2206007036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM			PC Info Complete	12/12/2011 12:00:00 AM	ADDRESS	34.21399	-118.47971	POWER AND ENERGY. NEW 600A SERVICE UPGRADE FOR KITCHEN IN AN EXISTING WAREHOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5955	17041-10001-36987	1460 W 27TH ST	90007	8	123B197  1350	5054032011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM			PC Approved	01/22/2018 12:00:00 AM	ADDRESS	34.03028	-118.29351	**Fee expedited per applicantInstall new PV1 on 2 separate structures of an SFD, total system 22.3kW AC. using (97) modules with (97) microinverters, (1) 200A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5956	12041-20000-21832	801 S GRAND AVE # 300	90017	9	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.04581	-118.25842	Install lighting, receptacles, and electrical water heater for remodeled suite 300.  Plan checked for T-24 energy onlly.  TENANT IMPROVEMENTS WORK ON 1,535 SQ. FT. OF THE TOTAL FLOOR AREA;  NEW NON LOAD-BEARING WALLS, NEW CEILING GRID AND LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5957	18041-20000-25200	5555 W MELROSE AVE Stage 20	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Medium and low voltage distribution equipment replacement for commercial facility Stage 20.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5958	13041-20000-16216	4297 S CRENSHAW BLVD	90008	8	114B185  1048	5024007023	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.00548	-118.33408	Existing Retail space.  New 1000 amp service.  Shell only, Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5959	11041-10000-00227	2100 E PACIFIC COAST HWY	90744	15	033B213    10	7428007003	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	33.79122	-118.23692	REPLACE AN EXISTING FIRE PUMP SYSTEM IN THE SOUTH PLANT OF TESORO REFINARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5960	17041-10000-21623	421 E 116TH ST	90061	15	084B205  1548	6083006029	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	33.92928	-118.26569	PC FOR ROOF MOUNTED PV SYSTEM WITH STORAGE BATTERY. PV SYSTEM SIZE 3.0 KW ACTOTAL OF 8 PV MODULES WITH OPTIMIZERSBATTERY IS TESLA POWERWALL 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5961	16041-10000-42904	17740 W RAYEN ST	91325	12	195B129   251	2768012035	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Issued	12/07/2016 12:00:00 AM	ADDRESS	34.23192	-118.52133	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.08KWac.(19)AC MODULES-SPR-E20-327-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5962	15041-10000-32862	545 W 2ND ST	90731	15	018B197  1402	7451017009	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	33.74222	-118.2889	PV1. NEW ROOF-MOUNTED SOLAR SYSTEM ON EXISTING BUILDING. TOTAL SYSTEM SIZE IS 3KW AC. (10) MODULES-KYOCERA # KU2656ZPA(1) INVERTER- ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5963	19041-20000-11625	7649 N AMPERE AVE	91605	2	186B161    81	2303016037	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.21009	-118.41872	addition of (1) tesla ESS 5KW to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5964	17041-10000-23770	225 S 26TH ST SUITE 37	90402	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			PC Info Complete	07/27/2017 12:00:00 AM	ADDRESS	34.04772	-118.49098	TITLE 24 PLAN CHECK FOR TI (RETAIL TO RETAIL) - TOTAL AFFECTED AREA = 1047 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5965	18041-20000-17960	20631 W CHESTNUT CIR (#273)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.29337	-118.58335	Plan check for a PV1 roof-mounted PV system. System size is 2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5966	13041-10000-22046	800 N AVENUE 63	90042	14	156A233   250	5486029001	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.12155	-118.17852	PV1 ROOF-MOUNTED INSTALLATION; 1.5 KW SYSTEM WITH:(6) MODULES: PHONO PS250P(6) MICROINVERTERS: ENPHASE M215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5967	15041-10000-13462	450 S WESTERN AVE UNIT 102	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS, NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 740.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5968	15041-10000-41814	1519 S GRANVILLE AVE	90025	11	126B149   522	4262005003	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.04209	-118.45779	Installation of a new FA to a 9-units 3-story apartment.  (1) FA , (1) Communication panel, and (40) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5969	14041-20000-13107	8402 W MCGROARTY ST	91040	7	204B189  1118	2560037007	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.25236	-118.31613	Roof mounted PV system with Optimizers and transformerless inverter.  System size 5.80KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5970	19041-10000-26219	4954 E MERIDIAN ST	90042	14	156A225   194	5476017014	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Expired	11/15/2023 12:00:00 AM	ADDRESS	34.12232	-118.20699	PV1 roofmounted system, system size is 4.575 KWdc/ 3.8 KWac. Scope of work is 15 modules (Hanwha Q Cells) with optimizers (SE320) and a central inverter (SE3800H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5971	18041-20000-38184	10532 W BURBANK BLVD	91601	2	174B177   587	2417001046	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM			PC Approved	10/05/2018 12:00:00 AM	ADDRESS	34.17201	-118.36066	ti to an existing commercial building, adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5972	19041-10000-25831	10301 N MELVIN AVE	91326	12	204B117   181	2708024001	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.2576	-118.56022	INSTALLAION OF NEW ESS(TESLA POWER WALL TO EXISTING PV SYSTEM AND 225A SERVICE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5973	13041-10000-24086	2920-2930 W ROWENA AVE BLDNG 4	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM	04/01/2015 12:00:00 AM		Issued	04/01/2015 12:00:00 AM	ADDRESS	34.10823	-118.26884	"400A UNDERGROUND PULL SECTION. PLAN CHECK FOR POWER .CONSTRUCT BUILDING 4 OF 6 WHICH INCLUDES:  2- ""B2"" UNITS, 4-""B3"" UNITS- 6 UNITS TOTAL. BUILDING REFERENCE APP # 13010-10000-02662"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5974	17041-10000-44930	1122 S GAYLEY AVE # 101 B	90024	5	132B149   108	4363023030	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Issued	12/18/2017 12:00:00 AM	ADDRESS	34.05976	-118.44586	PC for power and energy for first time restuarant tenant. Installing three new panels, new equipment, receptacles and lights. Total area is 2730sqft. B# 17016-10000-25128.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
5975	18041-20000-05402	7969 W MELROSE AVE	90046	5	141B177   539	5527013005	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.08395	-118.36341	Addition/change of use to (E) commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5976	18041-10000-08895	10752 W ASHBY AVE	90064	5	126B157  1360	4255021039	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.03749	-118.42377	Plan check for Battery back up system Tesla 2.0. to existing PV system. Total battery (2) 14.5kWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5977	18041-20000-36419	17236 W ELKWOOD ST	91406	6	189B133   713	2204013014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.21266	-118.509	Plan check for a PV1 roof-mounted PV system. System size is 12.95 kWdc/15.2 kWac and consists of (2) inverters, (37) modules, (2) batteries, (2) load centers, and (1) transformer.$24.21 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5978	16041-20000-02576	16430 W TUPPER ST	91343	12	198B137   571	2676025006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.23922	-118.49054	Install a solar array on a SFD, interconnect with a 200A MSP (derating main to 175A). There is an existing system on roof rated 3kW. New system is rated 6kW, ungrounded. (25) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5979	13041-20000-14703	13280 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24. 15 PANELS IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5980	15041-10000-40922	3831 S DEGNAN BLVD	90008	10	117B185   706	5033012013	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.01646	-118.33015	PV1, ROOF MOUNTED SOLAR SYSTEM WITH (30) KYOCERA #KU2656ZPA MODULES (1) 7.6KW-AC INVERTER, FRONIUS # PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5981	13041-10000-28627	5840 W CENTINELA AVE	90045	11	102B169    68	4103005033	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	33.97633	-118.38267	REMODEL OFFICE AREA WITHIN (E) WAREHOUSENOTE THIS WORK  INCLUDES NEW 600A DISTRIBUTION BOARD AND PANELBOARDS; THIS WORK IS DONE BY THE OWNER IN PRPARATION FOR CHANGE OF USE AND A NEW TENANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5982	18041-20000-00086	14071 W TYLER ST	91342	7	228B153   274	2503019002	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.32211	-118.44022	PV1.  Installation of 11.2 kW DC roof mounted grid tied PV system.  String inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5983	16041-20000-41302	11735 WETHERBY LANE	90077	5	153B141   276	4377045006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	PIN	34.11172032	-118.4763532	upgrade service from 400 to 600 amps	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5984	17041-20001-06006	8106 W 3RD ST	90048	5	138B177   751	5511029035	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Approved	03/20/2017 12:00:00 AM	ADDRESS	34.07197	-118.36625	03/20/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the lighting controls and fixture types.*****Previous Work Description*****ti to an existing commercial space.  adding new lighting new controls to existig panels.  plan check for energy only.  total square feet 1332	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5985	16041-10000-23673	11219 S HOOPER AVE	90059	15	087A211    86	6070014018	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Expired	08/13/2018 12:00:00 AM	ADDRESS	33.93253	-118.25237	PV1. NEW SOLAR SYSTEM FOR AN EXISTING DUPLEX BUILDING. TOTAL SYSTEM SIZE IS 3.0KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5986	16041-10001-20686	1061 S BROXTON AVE	90024	5	132B149    64	4363024005	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.06138	-118.44636	Changes to approved set of plans. Installing additional light fixtures and receptacles. Note changes under delta 4. ((((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING(RESTAURANT). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING RESTAURANT. TOTAL AFFECTED AREA IS 1478 SQ. FT. B#16016-10000-12511))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5987	17041-20001-01687	12970 W BLAIRWOOD DR	91604	2	162B161   456	2385015011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.14076	-118.41654	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5988	18041-20003-32460	10754 W WALNUT DR	91040	7	201B177   119	2542029008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	34.24984	-118.36466	PV1.  Install roof mounted PV system sized 14.75 kW AC interconnected with main service panel.  Energy storage system.$0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5989	18041-10001-16351	1501 N STRADELLA ROAD	90077	5	147B149   262	4377036001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.09982	-118.45843	OFF OUR PLAN CHECK PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 12KVA SYSTEM INCLUDING 2 INVERTERS(SMA SB 6.0-US) AND 29 SUNCECO SEP-310 310W POLY AND 11 SUNCECO SEP-260 260W MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5990	09041-10006-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Review the Master 34.5kv single line plans showing the trip settings of the overcurrent devices up to the main swbds serving the North Concourse and the South Concourse of the TBIT. C oordination study indicates the trip setting values and load shedding sequences undernormal condition and under 9 fault conditions. as determined by LAWA.Revisions of electrical plans for the north  and south concourses at TBIT -GDN 062	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5991	19041-20000-14117	10114 N DONNA AVE	91324	12	204B121   357	2729002037	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.25427	-118.54795	INSTALLING NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 16.08KW DC/11.52 KW AC. SCOPE OF WORK INCLUDES (48) LG PV MODULES WITH ENPHASE IQ 7 MICROINVERTERS, AND A ENPHASE AC COMBINER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
5992	14041-10000-04194	2800 VIA CABRILLO MARINA	90731										Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM				Ti in dining area of double tree hotel. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5993	18041-20001-25363	8330 N LOUISE AVE	91325	12	192B133   232	2690017112	RE11-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2018 12:00:00 AM			PC Approved	08/15/2018 12:00:00 AM	ADDRESS	34.22187	-118.50965	8/15/2018changes to an approved set of plans.  changes to (2) inverter delta solivia 5.2TL and reduction of modules to (34) 315W.this is plan check only.  PV1.  Install 11.285 kW roof mounted grid tied PV system.  (37) modules with 4.2 and 5.0 kW rated string inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5994	12041-10000-23117	7475 N FALLBROOK AVE	91307	12	186B097   417	2021015014	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.2064	-118.62364	Ti in a church. New service, panel, and ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5995	13041-10000-32250	3485 S ROSEWOOD AVE	90066	11	114B149   949	4244010018	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.00552	-118.44814	PV1, Install 4 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 16 modules Yingli YL250p-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5996	13041-20000-24806	12852 W RUNWAY ROAD PV-2	90094	11	102B161  1221	4211033040	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	33.97543	-118.41892	PV-2. Plan check for PV system for community center. One 75kW inverter. Solar fees capped out during Submital therefore final fees = 0.00	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
5997	19041-10000-20644	2044 E SACRAMENTO ST	90021	14	123A217   245	5166010026	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.03041	-118.23061	Power plan check for a 600-Amp service upgrade with new equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
5998	10041-20000-24354	10880 W WILSHIRE BLVD #1150	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	ADDRESS	34.05885	-118.44283	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR OFFICE TI UNIT #1150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
5999	13041-20001-29230	21820 W BURBANK BLVD BLDG A	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.17228	-118.6032	"(((changes to approved set of plans. change clouded delta 4. use of fuse let thru to protect meter cabinet only OK)))PV-2.  "" $0 permit fee is due to the 2012 Senate Bill No. 1222"" Plan check power for 135KW DC roof mounted photovoltaic system for Warner Gateway Building A. Building permit and clearances under #13016-10000-21826"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6000	16041-10000-38016	4501 W COLORADO BLVD	90039	13	162B205    19	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.14246	-118.2705	PC FOR TI TO OFFICE, LAB SPACE. NEW 800A DISTRIBUTION BOARD WITH STEP DOWN TRANSFORMER. NEW POWER AND LIGHTING IN EXISTING BUILDING. EXISTING GEN. ON SITE. INSTALLING NEW UPS SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6001	14041-20000-24796	7000 S HOOVER ST Unit #3	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #3.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6002	13041-10000-35853	6360 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	07/22/2014 12:00:00 AM		Issued	07/22/2014 12:00:00 AM	ADDRESS	34.18619	-118.5972	INSTALLATION OF A NEW FIREALARM DEVICES IN HILTON HOTEL. TENANT IMPROVEMENT. 6 PANELS AND 1302 DEVICES. HIGHRISE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6003	13041-10000-18434	1645 W 24TH ST	90007	8	123B197   422	5054002025	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.03464	-118.29876	ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING TO MAIN PANEL FOR A SINGLE FAMILY DWELLING 2-STORY HOUSE. SYSTEM SIZED AT 9.8KW. STANDARD PLAN. 4 STRINGS, 40 MODULES(TRINA SOLAR TSM-245-PC05/PA05.18 ) , INVERTER FRONIUS #IG+V7.5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6004	17041-20001-07152	6711 N VAN NUYS BLVD	91405	6	180B149   185	2236010002	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.19252	-118.44905	changes to an approved set of plans.  changes include adding new lighitng new contols to (2) office rooms.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6005	12041-10001-16523	7746 N ATOLL AVE PV1	91605	2	189B157   879	2303010008	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2012 12:00:00 AM			PC Approved	09/18/2012 12:00:00 AM	ADDRESS	34.21128	-118.41994	Plan check only for new roof mounted 5.61KW photovoltaic system. Single family dwelling. Permit issued under previous application #12041-10000-16523.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6006	16041-10000-12527	230 N RIDGEWOOD PL	90004	4	138B189   547	5516013006	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Expired	05/11/2018 12:00:00 AM	ADDRESS	34.07545	-118.31444	PV1, INSTALL 4.335 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(17) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI -3.6-OUTD-S-US Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6007	14041-20000-28278	11620 W WILSHIRE BLVD suite 370	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	Plan check for energy only. TI to office on 3rd floor of existing high rise office building. New lighting, incl. emergency. 4,047sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6008	13041-10000-16425	750 S LAMAR ST rd canopy	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE  (7.) roadability canopy (9400SF open structure) BUILDING. includes 300KVA transformer. includes 225A panel with 17 30-40hp nondwelling equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6009	17041-20001-01682	6431 N INDEPENDENCE AVE	91367	3	180B109   592	2149003039	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Approved	03/24/2017 12:00:00 AM	ADDRESS	34.18737	-118.59079	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6010	12041-10000-07077	1232 E PALMS BLVD	90291	11	111B149   545	4242013020	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.0013	-118.45484	New 8.7kw rooftop photovoltaic system for an existing home.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6011	15041-10000-23317	8550 N BALBOA BLVD 275	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.22649	-118.5024	TI 24 RELOCATE LIGHT FIXTURES INSTALL (7) 120V OUTLETSTOTAL SQ FT = 2040	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6012	16041-10000-13648	18840-18860 W SHERMAN WAY	91335	3	183B121   135	2126001001	[Q]C2-1VL-CDO-RIO, [Q]P-1VL-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.20083	-118.54423	PC FOR POWER AND ENERGY. PROPOSED 3-STORY  49-UNITS APT. BLDG. ON 1ST, 2ND, 3RD STORY MIX-USE WITH   RETAIL/LOBBY AND GYM ; GARAGE LOCATED @  BASEMENT LEVEL. SERVICE SIZE: 2000 A 120/208V 3-PHASE 4-WIRES WITH  11- TYPICAL UNITS.  TOTAL AREA  for T24 is 50,714 SQ FT. B # 16010-20000-0222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6013	19041-10000-42646	5935 W PICO BLVD	90035	5	129B173   314	5087022030	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	03/01/2021 12:00:00 AM		Permit Finaled	08/24/2023 12:00:00 AM	ADDRESS	34.05213	-118.36902	"FEE ESTIMATE ONLYFULL PC FOR A NEW 1200A SERVICE (277/480 3P,4W), THAT FEEDS A 1200A MAIN SWITCHBOARD WHICH FEEDS HOUSE LOADS, VARIOUS HVAC LOADS. THE 1200A MAIN SWITHBOARD ALSO FEEDS TWO 1600A DISTRIBUTION BOARDS WHICH SUBFEEDS VARIOUS SUBPANELS. TOTAL AFFECTED AREA IS 107,975 SFQT. FROM BUILDING:""Seven story mixed use building consisting of five residential levels of type IIIA over one type IA residential level over a commercial ground level and two subterranean type IA garage levels. 123 residential units. Total of 16 units with thirteen (13) units to be reserved for Extremely Low Income Households."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6014	19041-10000-49056	3243 W HOLLYDALE DR	90039	13	153B209  1213	5437014013	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.11176	-118.25872	[EPLAN] INSTALATION OF A NEW ESS (TESLA POWERWALL) TO AN EXISTING PV1 SYSTEM. CONNECTED TO A 200 AMP EXISTING SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6015	17041-10000-21175	14700 W SHERMAN WAY	91405	6	183B149    84	2219006016	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Issued	07/06/2017 12:00:00 AM	ADDRESS	34.20093	-118.45312	Installation of 5 new pole mounted lights on private street.  Lighting hardscape area = 12,780 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6016	17041-10000-03095	1426 S WEST BLVD	90019	10	129B185  1178	5082013024	R2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.04675	-118.33403	PC for a PV system on residentail. Total system size is 4.2 KWac with 20 modules.(20)MODULES-REC SOLAR: REC275TP(1)INVERTER-ABB: PVI-4.2-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6017	13041-10000-35037	843 S LOS ANGELES ST	90014	14	126A211    15	5145014003	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.04128	-118.25358	PLAN CHECK FOR POWER AND ENERGY PER APPLICANTS REQUEST.INTERIOR TENANT IMPROVEMENT FOR AN OFFICE TENANT. FOR SUITE 301 URM BLDG.BUILDING PERMIT # 13016-10000-25753	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6018	17041-10000-13641	851 S GRAND AVE	90017	14	127-5A209  54	5144020012	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM			PC Info Complete	04/26/2017 12:00:00 AM	ADDRESS	34.04476	-118.25923	PC FOR TI -24 ENERGY ONLYTOTAL AFFECTED AREA OF 388 SQ.FTSCOPE INCLUDES REPLACMENT OF 5 FIXTURES.UNDER BUILDING APP# 16016-10000-31205	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6019	19041-10000-48965	550 S HOPE ST Ste. 2330	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.04989	-118.25574	Energy plan check for a T.I located on the 23th floor of a commercial building. Scope includes new lighting and equipment with a total lighting area of 7,229-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6020	15041-10000-19251	5900 W SUNSET BLVD	90028	13	147A191    82	5545015001	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			Corrections Issued	06/19/2015 12:00:00 AM	ADDRESS	34.09788	-118.31816	T-24 ONLY, ADDING NEW LIGHTING TO AN (E) BUILDING, RESTAURANT. UPGRADING SERVICE TO 200AMP. TOTAL SQ. FT. 1370. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6021	17041-10000-03761	7289 W WORLD WAY NORT	90045	11	090B161    67	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	PIN	33.94534804	-118.41786236	Plan check for Power only in existing Parking lot at LAX. Service dedicated for EV Chargers station. Service 800 A  and install 10 EV chargers. EV chargers in methane zone install underground conduit for EV Chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6022	18041-10000-45675	1010 N WILMINGTON BLVD	90744	15	033B201   768	7415029032	[Q]C1.5-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.78265	-118.27427	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6023	17041-10000-18517	2049 S CENTURY PARK EAST 6TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 FOR TI (RENOVATION TO PUBLIC RESTROOMS ON 14TH FLOOR-HIGH RISE) TOTAL AFFECTED AREA 410 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6024	12041-20000-07259	14435 W SHERMAN WAY	91405	2	183B149    39	2217003046	C1-1VL, P-1VL, QP-1VL, [Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.20136	-118.44753	Lobby repair at ground and second floor, pan-check for lighting compliance and egress/exit lighting.( FIRE DAMAGED BLDG)  Existing permit 12041-20000-06189.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6025	18041-10000-24878	19537-19545 W ASTOR PL	91324	12	198B117   258	2761035101	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			07/03/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.23729	-118.5593	Plan check for power only for a New 5 unit townhouse building with 600A Service. Building Permit #18010-30000-01138NOTE: Site lighting is under PCIS#18010-30000-01138	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6026	19041-10000-24685	9760 W PICO BLVD	90035	5	129B165  1239	4307004***	C4-1VL-O, R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.05401	-118.40151	Replace fluorescent troffers with new LED retrofit kits on 1st and 2nd floor (Indoor only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6027	15041-20000-12481	6400 N CANOGA AVE Suite 330	91367	3	180B105    61	2149001020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM			PC Approved	04/27/2015 12:00:00 AM	ADDRESS	34.18665	-118.5972	TItle 24 plan check only.  Total area = 1,005 sq. ft.  T.I. to existing commercial space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6028	14041-20000-19277	113 S LA BREA AVE 1ST FLOOR	90036	5	138B181   895	5513019042	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.07317	-118.34429	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY ONLY.  EXISTING HIGH RISE BUILDING WORK TO BE DONE ON THE FIRST FLOOR ONLY.  ALL CIRCUITS ARE EXISTING ADDING NEW FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6029	15041-20000-34488	20457 W RUNNYMEDE ST	91306	3	186B109   519	2114008036	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.20602	-118.57939	PV1, roof mtd solar system 4.24 kW. (16)modules: #KU2656ZPA, (1) inverter: PVI-3.6-OUTD-S-US-Z-A. standard plan is used	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6030	13041-10000-34768	19550 W NORDHOFF ST	91324	12	195B117     9	2783028016	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.23529	-118.55947	- New Auto Dealership ('Toyota') . .(per Francis plan review). new car dealership to include car sales, car repair garage & offices. lighting and power pc. new service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6031	17041-10001-25672	4151 W PROSPECT AVE BLDG A	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	"Revision on the approved plan noted as Delta 1 to indicate all new equipment that was not clearly indicated on the previously approved plan. This is plan check only, permit is covered under master.<<PC FOR POWER. RELOCATING 1200 A  SWITCHBOARD AND INSTALLING NEW 750KVA TRANSFORMER IN BUILDING  ""A"" BASMENT.SCOPE INCLUDES NEW TRANSFORMER AND CONDUTORS TO RELOCATED SWITCH BOARD.>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6032	13041-20000-22977	14735-14737 W FRIAR ST	91411	6	180B149   959	2241002020	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Apartment			08/22/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	34.18583	-118.45427	LOST PLANS. PER INSPECTOR REQUIST, NEW SET OF APPROVED PLANS. NEW TOWN HOMES. START IN 2007	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6033	16041-10000-35970	6255 W SUNSET BLVD STE. 950	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.09815	-118.32564	T.I. REMODEL ON (E) COMMERCIAL SPACE STE. 950. INSTALL NEW LIGHTS AND RECEPTACLES, NEW BRANCH CIRCUITS WITH LOAD < 100A. PC FOR T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6034	14041-20000-14444	433 W 73RD ST	90003	8	102B201   998	6020029004	R2-1	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	33.9738	-118.28167	PV1.  Install 8.5 kW roof-mounted utility-interactive PV system.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6035	17041-10000-29435	9081 W PICO BLVD	90035	5	132B169   788	4332005013	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.05543	-118.38962	REMOVE EXISTING (6) HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 6450 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6036	12041-20000-03064	11240 N TAMPA AVE	91326	12	210B117    29	2822019004	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.27425	-118.55621	New gas station with conveniance store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6037	16041-10002-35402	6399 W WILSHIRE BLVD	90048	5	135B173   818	5510028012	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.06391	-118.36796	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. CHANGE NOTED DELTA 3. REMOVAL OF 2 WAY CPMM SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6038	12041-10000-04323	500 N PIER A ST BERTH 161	90744	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	33.76414	-118.26561	new 1200a service and panels for furture cng facility	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6039	17041-10000-05969	1610 S VERMONT AVE	90006	1	126B197   217	5056022017	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.04385	-118.29142	Plan check for Title 24 only in existing space, replace existing outdoor lighting fixtures with LED fixtures. Total area: 26,025 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6040	18041-20001-28007	12462 N MARVA AVE	91344	12	219B129   288	2601050015	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.29786	-118.51808	Expedite per applicat requestPlan check for PV roof mouted system, system size: 10kW with 41 modules and 1 inverter(10.0kW) connected to 225A panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6041	19041-10002-24186	6605 S OCEAN FRONT WALK	90293	11	096B149   322	4116002047	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	33.95981	-118.45206	"DELTA ""1"" CHANGES TO APPROVED PLANS.REDUCTION OF TOTAL PV MODULES NUMBERS.  <<<PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND TESLA SOLAR ROOF MODULES, (98) ROOF MODULES (1)7.6 KW INVERTER. TOTAL SYSTEM SIZE IS 6.7925 KWDC AND 7.6 KWAC.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6042	15041-20000-03460	9200 N OAKDALE AVE 10TH FLR	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.23811	-118.56674	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANEL.  nEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN THE 10TH FLOOR.  TOTAL SQUARE FOOTAGE 10930.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6043	17041-10000-11990	7350 N FIGUEROA ST	90041	14	162A231   138	5709006019	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Issued	04/13/2017 12:00:00 AM	ADDRESS	34.13721	-118.18772	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 21750 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6044	11041-10000-14518	4310 N ARCOLA AVE	91602	4	165B177   631	2424023010	RE11-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.14847	-118.35485	New 2-story single family residence plus basement.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6045	15041-20000-26467	15016 W MARBLE DR	91403	4	163-5A147 180	2278005001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.14219	-118.46094	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (36) modules, and (36) power optimizers. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6046	19041-10000-47204	11150 W GAULT ST	91605	2	183B173   146	2319022002	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	12/11/2020 12:00:00 AM		Permit Finaled	07/07/2023 12:00:00 AM	ADDRESS	34.19927	-118.37408	Permit fee is $0.00 due to AB1414PLAN CHECK FOR A NEW 100KW AC  ROOF MOUNTED SOLAR SYSTEM. SCOPE INCLUDES  (342) MODULES, ( 171) OPTIMIZER AND ONE 100KW CENTERAL INVERTER INTERCONNECTING THROUGH A SERVICE PANEL ON A COMMERCIAL BULDING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6047	17041-10000-16678	9600 N LURLINE AVE	91311	12	201B109   290	2748040027	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.24455	-118.58404	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 26400 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6048	16041-20001-14416	3808 S BAGLEY AVE	90232	5	120B165   772	4206030003	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.02522	-118.39466	06-23-16 Change to an approved set of plan. Changes include relocated lighting fixtues in delta 9. Changes apply to delta 9 only. TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTD LOAD <400AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOATGE 2556.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6049	16041-10000-24388	2559 E 25TH ST	90058	14	117A219   127	5168021005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.01542	-118.22595	PC FOR ENERGY ONLY. REPLAEMENT OF HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 8916 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6050	18041-10000-39399	441 S TOWNE AVE	90013	14	127-5A213 284	5147009028	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.04355	-118.24174	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6051	15041-10000-05234	100 N LA CIENEGA BLVD #C240	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.07466	-118.37629	Full plan check for a first time tenant in a 2-story retail commercial building; Total area is 26187 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6052	18041-10002-20550	642 N SAINT CLOUD ROAD	90077	5	144B153   881	4362017050	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	34.0872	-118.44004	Changes to an approved set of plans. All changes are clouded under delta 2. Changes include revising single line diagram to add a 60KW generator, 200A ATS, revising single line diagram, revising load calculations, and revising floor plans. BUILDING PERMIT # 15010-10000-02171	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6053	13041-10000-08047	8818 W SATURN ST	90035	5	129B169   203	4305014057	R1-1-O	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.053	-118.3847	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW. USING 14 MODULES. ENPHASE MICROINVERTER. M215. MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6054	18041-10000-19242	836 S STANFORD AVE	90021	14	124-5A213 300	5146023038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.03552	-118.24729	REPLACE AN EXISTING FIRE ALARM SYSTEM WITH A NEW ONE FOR A DAY CARE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6055	19041-20000-42986	5510 S LINCOLN BLVD STE 450	90094	11	102B157   355	4211022023	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	33.97299	-118.43051	Plan check for Title 24 energy only, new lighting, control. Total area: 4974 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6056	19041-10000-32104	3977 W BEVERLY BLVD	90004	13	138B197   312	5520021009	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	04/21/2022 12:00:00 AM		Issued	04/21/2022 12:00:00 AM	ADDRESS	34.07646	-118.29535	FULL PLAN CHECK FOR A NEW 5 STORY 67-UNIT MIXED USE BUILDING . SCOPE OF WORK INCLUDES (2)  NEW SERVICES (THREE PHASE 120/208) RATED AT 800, AND 2000-AMP. , TWO NEW DISTRIBUTION BOARDS FEEDING VARIOUS SUBPANELS AND HOUSE PANELS. TOTAL AFFECTED AREA IS 40078 SQFT. B#19010-10000-00602	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6057	16041-20003-37951	6929 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM			PC Approved	11/19/2018 12:00:00 AM	ADDRESS	34.19659	-118.49256	11/19/2018plan check for lost set of plans, 800 amps service upgrade.this is plan check only.  ((((Upgrade electrical service - new 800 A 3ph/4w 120/240V service.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6058	14041-10003-08514	6801 W HOLLYWOOD BLVD #170	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM			PC Approved	08/22/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	((8/22/2014 - Changes made to approved set.  Deleted low voltage timeclock override switches 'SLV1' and 'SLV2'.  Updated lighting control riser diagram and title 24 forms to relect changes.  Changes marked with delta 8))Master permit work description:  T.I. to existing retail space for Shoe Palace.  Install new general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6059	13041-20000-08801	6021 N TOPANGA CANYON BLVD	91367	3	177B101   132	2146025004	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.17998	-118.60615	Change to lighting and loads for an existing retail space.  (Verizon Wireless)  Load is 129.57 amps.  PLAN CHECK ONLY for Energy,  ALL EMERGENCY LIGHTS ARE EXISTING AND NOT TO BE RELOCATED PER APPLICANT.  NO PLAN REVIEW FOR EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6060	19041-10000-41429	5100 S RUSSO ST	90230	11	108B161   931	4221025030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	33.98895	-118.41202	[E-PLAN] PV1. NEW ROOFTOP SOLAR SYSTEM WITH LG CHEM BATTERY BACKUP. SYTEM CONSIST OF 19 MODULES (LG335N1C-V5 335W) WITH 19 OPTIMIZERS (SE P370) AND 1 CENTRAL INVERTER (SE76000A-US). SYSTEM SIZE IS 6.37 KWdc AND 7.6KWacPANEL UPGRADE TO BE PERMITTED SEPARATELY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6061	17041-10000-33880	2224 N BEVERLY GLEN PL	90077	5	151-5A151 305	4380004023	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM			Corrections Issued	09/21/2017 12:00:00 AM	ADDRESS	34.11033	-118.4469	PC AND PERMIT FOR 400A SERVICE UPGRADE 120/208. PC FOR POWER ONLY. THIS IS PC PER APPLICANT REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6062	17041-20000-28497	14526 W HARTLAND ST	91405	6	183B149   674	2219025034	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			08/11/2017 12:00:00 AM	01/30/2019 12:00:00 AM		Issued	01/30/2019 12:00:00 AM	ADDRESS	34.19496	-118.44984	Plan check for power and energy. New 3-story,  22-unit apartment building over subterranean garage.1600A 120/240V 3ph 4w service. Building application #12010-20000-02652.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6063	15041-20001-36994	9504 N WHITAKER AVE	91343	12	198B133    42	2686020009	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM			PC Approved	11/13/2015 12:00:00 AM	ADDRESS	34.24325	-118.499	**Expedite Fee*PV1, roof mounted solar 12.7kW AC(44)modules: SPR-327NE-WHT-D(1)inverter: SunnyBoy 5000TL-US(1)inverter: SunnyBoy 7700TL-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6064	19041-20002-38830	18735 W LISBURN PL	91326	12	219B121   169	2870002012	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Issued	11/12/2019 12:00:00 AM	ADDRESS	34.29516	-118.54203	$0 PERMIT AND PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, ADDITION OF A PANEL TO SINGLE LINE AND RELOCATION OF EQUIPMENT ON ROOF PLAN AND ELEVATION DRAWINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6065	13041-10000-07656	209 N ROCKINGHAM AVE	90049	11	132B137   285	4406001019	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.05896	-118.49148	PC FOR POWER. UPGRADE PANEL FROM 400 TO 600A SFD. 120/240 delta according to applicant. existing loads and panels except for the 600A upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6066	16041-10002-43319	5634 W SANTA MONICA BLVD	90038	13	144B193   768	5536018021	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.09063	-118.31261	Changes to an approved set of plans. All changes are clouded under delta 2. Relocating bug eyes from lighting floor plans from ceiling to wall mounted in corridors. Note: permit is paid under PCIS#16041-10000-43319	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6067	12041-20000-02034	11400 W OLYMPIC BLVD s.1200	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.03666	-118.44346	office t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6068	18041-10000-35294	6614-6624 S BROADWAY	90003	9	102B201   124	6012002026	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.10	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	33.97934	-118.2781	PLAN CHECK FOR POWER AND ENERGY FOR - Change of use from Retail to Laundry Mat to expand existing adjacent Laundry Mat. Hours of Operation are limited to 7am to 11pm. CONNECTED LOAD >400A ON EXISTING DISTRIBUTION SYSTEM AND PANELS - TOTAL AFFECTED AREA = 4868 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6069	13041-10000-08884	750 S LAMAR ST OUTBOUND-PORTAL	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	PLAN CHECK POWER FOR NEW UNOCCUPIED ACCESSORY STRUCTURE HOUSING AUTOMATED SECURITY SCANNING EQUIPMENT FOR OUTBOUND TRUCK/TRAILER COMBINATIOIN AT UNION PACIFIC RAILROAD LATC YARD. EXISTING SERVICE. NEW PANEL AND BRANCH CIRCUITS. SITE LOCATED IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6070	11041-10000-09788	14530 W NORDHOFF ST	91402	7	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	09/14/2012 12:00:00 AM	ADDRESS	34.23519	-118.44861	NEW WALMART TO TAKE OVER EXISTING RETAIL SPACE.  REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6071	16041-10000-07108	7974 N CANTALOUPE AVE	91402	6	189B153   455	2213013018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Expired	03/30/2018 12:00:00 AM	ADDRESS	34.21608	-118.43362	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5040W DC INTERCONNECTED WITH MSP.(21) MODULES: SOLARWORLD SW 280 MONO (1)MICROINVERTER;ENPHASE  M250-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6072	18041-10000-04582	11285 W NATIONAL BLVD	90064	5	132B153   344	4363023032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.02652	-118.43134	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR WORK ONLY. TOTAL AFFECTED AREA 5610 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6073	14041-20000-18677	6115 N GLIDE AVE	91367	3	177B093   461	2035012003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.18167	-118.63851	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MAIN PANEL.(29) TRINA SOLAR MODULES TSM-255(1) SOLAR EDGE INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6074	17041-10000-35778	305 S OCEAN FRONT WALK 1-5	90291	11	109-5A141 110	4286030023	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	33.99451	-118.48022	PC for power and energy for new five story building with three floors for apartments, one floor for commercial and one floor for subterraenan parking with car lifts. Installing new 800A 240/120V servicefeeding a 600A service with seven new panels.B# 17010-10000-01504	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6075	14041-10000-18829	16116 W COHASSET ST	91406	6	186B141   287	2205023023	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM			Reviewed by Supervisor	07/23/2014 12:00:00 AM	ADDRESS	34.20651	-118.48425	permit to be pulled at EPC counter only. Plan check for energy only under 2013 energy code. scope is entire office and warehouse. BLDG#14016 30 13769: Repair exising roof due to fire damage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6076	13041-20001-34240	17584 W TUSCAN DR	91344	12	222B129   259	2601044015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/18/2014 12:00:00 AM	ADDRESS	34.30243	-118.51683	"changes to approved set. changing of the conduit size from 3/4"" emt to 1/2"" emt for source feederss only."" 0$ plan check fee due to senate bill 1222 from 2012""PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2 KWAC. 20 MODULES AND 1 INVERTER"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6077	16041-10003-08253	18816 W SAN FERNANDO MISSION BLVD	91326	12	210B121   184	2717006013	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.2734	-118.54293	PC FOR CHANGES TO APPROVED SET. CHANGES CLOUDED ON PLANS. CHANGES NOTED AS RELOCATION OF MAIN SERVICE PANEL AND ADDITION OF PERFORMANCE METER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6078	14041-20000-35858	14611 W HIAWATHA ST	91345	7	207B149   887	2648013004	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.25994	-118.45064	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system.16  327W pv modules across two strings (8+8).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6079	12041-10000-26680	10801-10807 N SAN FERNANDO ROAD Bldg B	91331	7	207B157   309	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Info Complete	11/26/2012 12:00:00 AM	ADDRESS	34.26635	-118.42259	"Methane mitigation submittal - Building 'B' Restoration of building. Interior and Exterior remodel. (Buildings A through D were submitted together application numbers are: (A) 12041-10000-26679, (B) 12041-10000-26680, (C) 12041-10000-26681, (D) 12041-10000-26682). <<Per applicant's request, Mr. Jose Delgado, the status was changed to ""Plan Check Only"".>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6080	10041-20001-19382	10351 W SANTA MONICA BLVD 410	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM			PC Approved	10/05/2010 12:00:00 AM	PIN	34.0585564	-118.42324002	Plan check only for T-24 Energy (general/emergency) lighting. Permit under #10041-90000-19382.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6081	11041-10001-07236	8500 W BEVERLY BLVD # 746	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM			PC Approved	07/18/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT OF AN (E) 2333 SF RETAIL SPACE WITHIN A COVERED HIGH RISE MALL.  MODIFICATION TO PREVIOUSLY APPROVED T-24 FOR SWITCHING ONLY TO ADD ADDITIONAL LIGHTING CONTROL TIME CLOCK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6082	19041-20000-27134	16429 W NAPA ST	91343	12	192B137    20	2689028035	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.2267	-118.49049	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWdc/3 kWac and consists of (1) inverter and (12) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6083	18041-10001-22428	1030 N SWARTHMORE AVE 4-104B	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Change to approved set by changing the feeder and conduit size. All changes under delta-1 only(((Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first time tenant. Total lighting area = 513 sq. ft.Note: Building application has been generated under 18016-10000-12045)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6084	13041-20001-35736	5430 N LOUISE AVE	91316	5	174B133   787	2258001061	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.16987	-118.50962	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.75KW. 19 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6085	16041-10000-44940	3543 W CASITAS AVE LOT 7	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12072	-118.25711	Plan check for Power 11 buildings SFD live work  3 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 7 of 11Note: Master Application Lot 7 type A2,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6086	16041-10003-12519	3812 W OAKWOOD AVE	90004	13	138B197    84	5501001023	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.07761	-118.28979	12/6/16PV1, Changes to an approved set of plans. Changes to reflect what is on the field. Changes include adding two new 100A panels on the single line diagram, and on the roof-layout	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6087	12041-20000-25834	12618 W KILLION ST	91607	5	174B161   531	2346008014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Expired	12/16/2014 12:00:00 AM	ADDRESS	34.17112	-118.40779	New 9.065kw rooftop mounted photovoltaic system for a single family residence.  System uses Enphase Microinverters.  Plan check is only for the PV system, Not for decreasing any main breakers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6088	15041-20000-31443	13274 W FIJI WAY STE 200	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Approved	09/22/2015 12:00:00 AM	ADDRESS	33.97902	-118.43558	TI TO SUITE 200. NEW LIGHITNG IN OFFICES. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6089	09041-10004-24270	380 W WORLD WAY NORTH-CONCOURSE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	APPLICATION ADDRESSES CHANGES TO APPROVED SET OF PLANS ;NOTE RFI  #'S ON DRAWINGS  ON WHICH CHANGES ARE BUBBLED: # 3544 ; # 3907 ; # 4164 : # 2310 ;# 2311; CHANGE OF FEEDER CB'S FOR PCA UNITS; UPDATED SHEET E5012(((((((((Revisions of electrical plans for the north concourse at TBIT -Revisions are noted in  bulletins (GB1 to GB5). On the plans, each change is clouded and noted to the reference GB.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6090	19041-20000-07115	8614 N VAN NUYS BLVD UNIT A	91402	6	192B149    35	2638001039	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.2266	-118.44937	Change of use from dental office to take out restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6091	18041-10000-23862	5054 W LOS FELIZ BLVD	90027	4	150B197   278	5589011003	RE11-1	Central	Hollywood	Los Feliz		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	08/04/2018 12:00:00 AM	ADDRESS	34.1094	-118.30003	PV1 ROOF MOUNTED SOLAR SYSTEM USING (20)AC MODULES AND A DEDICATED PV PANEL. TOTAL SYSTEM SIZE IS 6.42KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6092	11041-10001-18122	8231 W 3RD ST	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM			PC Approved	09/27/2011 12:00:00 AM	ADDRESS	34.07272	-118.36914	First Time Tenants, Tenant Improvement on the first floor in the Mercedes-Benz Driving Academy. Plan check for Power & Energy.    <Permit was issued under 11041-90000-18122.  Core & Shell: 08041-10000-02697>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6093	16041-20000-23182	515 S FLOWER ST FLOOR 22	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGHRISE.  20,533 SQFT. FLOOR 22.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6094	18041-20000-30474	12188 W VENTURA BLVD	91604	2	162B165   207	2369004042	C2-1VL-RIO, R4-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.14314	-118.39812	New lighting for (E) commercial retail space.  Plan check for energy - 458 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6095	19041-10000-04426	16901 W ENCHANTED PL	90272	11	129B121   160	4419001043	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.05166	-118.54814	$0 fee DUE TO AB1414 PLAN CHECK FOR ROOF MOUNTED 20KVA PV SYSTEM CONSISTING OF 2 CENTRAL INVERTERS (SOLAREDGE SE 10000H-US) WITH 61 MODULES USING (P370) OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6096	10041-10000-18843	1229 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/27/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.05192	-118.22653	Solar voltaic system installed on the roof of the building.  Consists of 5 modules, 5 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6097	18041-20000-27053	17556 W CHASE ST	91325	12	192B129   176	2787015011	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.22392	-118.5166	pv1install roof mounted pv system sized 13.4KW AC interconnected with msp.  (42) sunpower AC modules SPR-X21-350	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6098	12041-10000-21345	3607 N AMESBURY ROAD	90027	4	154-5A203 271	5592013008	R1-1	Central	Hollywood	Greater Griffith Park	YES	1882.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	01/07/2013 12:00:00 AM	ADDRESS	34.11635	-118.28007	Plan check for new roof mounted 6.9KW Photovoltaic system (Enphase M215 Microinverters).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6099	14041-10006-07239	11995 W BLUFF CREEK DR BLDG 5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			PC Info Complete	01/21/2016 12:00:00 AM	ADDRESS	33.98218	-118.40255	1/21/16: CHANGES TO AN APPROVED SET OF PLANS.  REMOVE 2 SENSORS (C-55 AND C-57)((((8/26/2015))))CHANGES TO AN APPROVED SET OF PLANS.  ADDING 3 SENSORS PER PAGE MG 2.00.Modification to an approved set by adding (38) sensors to the detecting system.((((4/27/2015))))CHANGES TO AN APPROVED SET OF PLANS.  ADDING 11 SENSORS PER PAGE MG 4.00.METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35606.BLDG PERMIT: 13010-10000-04244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6100	10041-10000-19081	621 S WESTERN AVE #104;105-106	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM			PC Approved	09/24/2010 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TIME TENANT-CAKE HOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6101	18041-10000-26013	4500 N WOODMAN AVE	91423	4	168B157   929	2360002030	R1-1-RIO, R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.15306	-118.43102	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIREALARM PANEL AND 45 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6102	18041-10000-01508	3790 W WILSHIRE BLVD	90010	10	132B193    69	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.06153	-118.30861	PC for T24 only for new and retrofit lighting in bar/lobby area. Installing new lights, receptacles, equipmentand two new panels. Total area 7719sqft. B# 18016-10000-00110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6103	14041-10000-35901	8968 N FULLBRIGHT AVE	91311	12	195B113    24	2781001025	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.23453	-118.57739	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6104	15041-10000-07940	7045 N SOPHIA AVE	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.19892	-118.4871	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 11520 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6105	19041-20000-51064	6050 N PENFIELD AVE	91367	3	177B113    65	2153006013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Issued	12/11/2019 12:00:00 AM	ADDRESS	34.18105	-118.56913	Plan check for PV roof mounted system, PV system size: 11.34KW with 1 inverter(10.0KW) and 36 PV Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6106	10041-10000-03267	6906 W HOLLYWOOD BLVD 2nd Floor	90028	13	147B181   194	5548006008	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM			PC Info Complete	03/01/2010 12:00:00 AM	ADDRESS	34.10137	-118.34052	T.I. for existing commercial building.  Install general and emergency lightings.  Plan check for energy only.Permit under 10041-10000-03280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6107	18041-10001-00830	8334 W FOOTHILL BLVD	91040	7	204B189    47	2560008030	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.25954	-118.31465	05-02-2018 Changes to an approved set of plan. Changes include lighting manufacturing and emergency lighting source to  inverter. Changes has been clouded as delta 5 . Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6108	16041-10000-08469	1201 S MAIN ST	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Closed	12/13/2018 12:00:00 AM	ADDRESS	34.03757	-118.25973	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES A TEMP.  800 AMP SERVICE. CONNECTED LOAD IS < 400AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6109	19041-10000-47382	454 E COMMERCIAL ST	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.05313	-118.23621	PLAN CHECK FOR LADOT BUS CHARGING STATION. SCOPE INCLUDES 11 POWER CABNETS AND 22 CHARGING STATIONS (DEPOT CHARGE BOX). EXISTING AND NEW EV CHARGERS ADDED LOADS  ARE BASED ON CONNECTED  LOAD PER NEC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6110	11041-10000-00465	2244-2254 S FIGUEROA ST	90007	9	123A205   107	5126006018	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	08/31/2011 12:00:00 AM	ADDRESS	34.03101	-118.27323	CONVERT RETAIL SPACES TO LIVE/WORK UNDER ADAPTIVE REUSE  - 11 UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6111	16041-20000-14113	340 S MAIN ST 1st Floor	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	33.99519	-118.47673	Plan check for energy only. INTERIOR TENANT IMPROVEMENT AT LOBBY. New lighting (incl. emergency) and receptacles. 840sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6112	19041-20001-00762	7809 W TORREYSON DR	90046	4	159B173   613	5570015012	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.12877	-118.3696	Expedite feePV1.  Install 17.16 kW roof mounted grid tied PV system with 13.2 kWh energy storage system.  (52) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6113	13041-10004-33753	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM			PC Approved	10/29/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	((10/29/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 4.  CHANGES INCLUDE THE ADDITION OF NEW LIGHITNG FIXTURES AND REVISIONS TO T-24 DOCUMENTS.  THIS IS PLAN CHECK ONLY.((((3/31/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  REVIONS TO THE LIGHTING FIXTURES NOTED DELTA 3 ON THE PLANS.MASTER PERMIT UNDER 13041 10001 33753EPC for T24 for Tom Bradley LAX project. Install a new 300KVA Xformer & a new 1200 Amp panel & Conduit stubs for (5) future tenant. No new load is added except 4 new lighting circuits. All FUTURE electrical installations require complete electrical plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6114	18041-10000-12547	8999 N BALBOA BLVD	91325	12	195B133     8	2690006017	(Q)C2-1VL	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.23353	-118.50275	Permit fee is $0.00 due to AB1414.PC for 396.7kW(ac) roofmounted solar system for Target. Installing 1392 PV panels (494.2kW(DC) , 4 inverters at 82.2KW, 1 inverter at 65.5KW and a 600A distribution panel board.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6115	14041-20000-16827	12200 W OLYMPIC BLVD Ste 400	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.03195	-118.45506	Plan check only on a partial 4th floor of a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6116	19041-10000-53845	6841 NORTHFORD DR	91042	7	198B201   176	2572039019	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	PIN	34.24098542	-118.28116929	PV1, NEW ROOFTOP MPUNTED SYSTEM, SYSTEM SIZE IS 6KWac/8.9KWdc, SCOPE INCLUDES, 28 MODULES (LG320N1K) WITH OPTIMZERS (SEP320) AND A CENTRAL INVERTER (SE6000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6117	18041-20000-35357	5850 S VERMONT AVE #D	90044	9	105B197    72	6004001024	[Q]C2-1	South Los Angeles	South Los Angeles	Voices		2371.01	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	33.98773	-118.29129	Plan check for Title 24 only in existing retail store T.I. Total area: 13728 sq ft. B#18016-20000-28958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6118	19041-10000-48400	4960 N RIGOLETTO ST	91364	3	171B097  1035	2075018014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.16116	-118.62512	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 11.4 KWac/11.78 KWdc. SCOPE OF WORK IS 38 MODULES (S-ENERGY SN310) WITH OPTIMZERS (SE P320) AND (2) CENTRAL INVERTERS (SE7600H-US-EV CHARGER & SE3800H-US).  NOTE MAIN BREAKER HAS BEEN DERATED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6119	12041-10000-06481	300 S DOHENY DR	90048	5	138B169   549	4335015050	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.07343	-118.38954	PLAN CHECK POWER AND ENERGY FOR OUTDOOR PATIO AREA. NEW HEATING EQUIPMENT FOR CANOPY. LOADS OVER 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6120	16041-20001-08859	430 S HOBART BLVD 1-68	90020	10	135B193   543	5503011021	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.06624	-118.30518	PV2.  Install 44.6 kW DC roof-mounted PV system on (E) apartment building.  (4) 9000W inverters with (144) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6121	10041-20000-11474	1212 N BERENDO ST	90029	13	144B197   200	5540016012	R3-1XL	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			06/16/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.09389	-118.29452	Plan check for 1.8KW Photovoltaic System for apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6122	14041-10001-04967	26220 S ATHENA AVE	90710	15	033B193   524	7411018013	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	33.78457	-118.30485	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(17) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6123	11041-20000-08965	15030 W VENTURA BLVD 10 to-16	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			PC Info Complete	05/19/2011 12:00:00 AM	ADDRESS	34.15272	-118.46063	T.I. to existing building due to fire damage.  Replace 6 subpanels.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6124	14041-20001-11209	5367 N WINNETKA AVE	91364	3	171B113    69	2166006007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.16778	-118.5711	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.25KW INTERCONNECT WITH MAIN PANEL.(1) TRANSFORMERLESS INVERTERS;  SOLAR EDGE SE6000 WITH OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6125	14041-10000-24537	6611 N WOODMAN AVE 1-30	91405	2	180B157   431	2238011007	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			Reviewed by Supervisor	09/16/2014 12:00:00 AM	PIN	34.190655	-118.43164511	PV2.  INSTALL 13770 W DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(54)MODULES: CANADIAN SOLAR CS6P-255P(2) INVERTER(S): SMA AMERICA SB7000US & SB6000TLUS (negatively grounded and ungrounded, respectively.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6126	17041-10000-09742	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC for a new Methane gas detection system. Scope includes 45 control devices with one control panel. Original lost set of plans are under PCIS#14041-10000-03448. Building permit :12010-10000-01270.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6127	19041-10000-20939	684 S MATEO ST	90021	14	124-5A217 187	5164020028	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	09/01/2020 12:00:00 AM	ADDRESS	34.03527	-118.23219	FULL PC FOR CHANGE OF USE FROM WAREHOUSE TO RETAIL. SCOPE OF WORK INCLUDES A NEW 1200 A SERVICE, NEW PANELS, AND NEW CIRCUITS, LIGHTING AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 29,835 SQFT. B#:19016-10000-02767	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6128	14041-10002-03218	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.14947	-118.43885	Installation of lighting and receptacles for Starbucks kiosk in a Ralphs supermarket.  Title 24 plan check for lighting system.  tITLE 24 IS UNDER SUPPLIMENTAL PERMIT 14041-10000-03218	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6129	19041-20001-06148	17437 W TARZANA ST	91316	5	168B129    38	2290004033	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.16042	-118.51301	Expedite per applicant request Plan check for PV roof mounted system, PV system size: 18.98KW DC, 16.13KW AC with 52 PV Modules and 2 inverters(11.4KW and 7.6KW), 125A sub panel connected to 400A MSP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6130	19041-20001-46968	6114 N PASEO LA VISTA	91367	3	177B085   137	2032030043	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.18327	-118.66749	Expedited plan check fee.PV1.  Install 17.11 kW DC / 14.16 kW AC roof mounted grid tied PV system.  (59) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6131	16041-10002-18796	2939 W LEEWARD AVE 1-80	90005	1	132B197   276	5077016017	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.05886	-118.28782	CHANGES UNDER DELTA 7. CHANGES TO REFLECT AS BUILT. SCOPE INCLUDES NEW DEDICATED FIRE PUMP SECTION AND REVISING ELECTRICAL ROOM FOR FIRE PUMP METER. RELOCATING FIRE PUMP METER IN ELECTRICAL ROOM.NOTE: PERMIT FEES ARE PAID UNDER MASTER APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6132	16041-20000-28116	5517 S HOLMES AVE	90058	9	108B213   309	5105012029	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Closed	05/15/2018 12:00:00 AM	ADDRESS	33.99244	-118.24133	TI to (E) fire-damaged building.  Plan check for power and energy - medical office/dental.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6133	13041-10000-21957	21650 W OXNARD ST 8th floor	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Installation of new offices/rooms in highrise building on 8th floor.  Relocated and newly installed lighting.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6134	14041-10002-30660	1355 S ABBOT KINNEY BLVD	90291	11	108B145  1290	4239027014	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	33.99081	-118.46608	(((11/18/2014 - Sup. application for title 24 plan check only.  Total area = 417 sq. ft.)))Install new plugs, switches and lights locations. Install power for ac at roof.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6135	16041-20000-19798	13227 W VALLEYHEART DR	91423	4	165B157   566	2375004048	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Expired	07/10/2018 12:00:00 AM	ADDRESS	34.14836	-118.4206	CHANGES TO AN APPROVED SET OF PLANS.  ADDITION OF 4 MODULES ONLY.PERMIT FEE PAID UNDER APPLICATION NIMBER 16041-20000-04211PV1.  Install 6 kW AC roof-mounted PV system.  Central inverter standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6136	16041-20001-06632	16407 W HAMLIN ST	91406	6	180B137   507	2231003028	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.18854	-118.49054	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. ADDITION TO EXISTING SYSTEM. ADDTION SYSTEM SIZE: 8.06KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6137	18041-10000-11202	555 W 5TH ST	90013	14	130-5A211 161	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR TITLE 24 ENERGY ONLY FOR A  NEW FOOD AND BEVERAGE KIOSK IN THE COURTYARD SCOPE INCULDES NEW PANEL TRANSFORMER AND LIGHTS. TOTAL AFFECTED AREA  375 SQ. FT INDOORS AND OUTDOORS. B# 17014-10000-05914	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6138	16041-30000-15831	7308 N KATHERINE AVE	91405	2	186B153   629	2217028002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.20351	-118.44317	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6139	19041-10000-52815	1153 N CYPRESS AVE	90065	1	145-5A219  22	5454025011	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	06/07/2021 12:00:00 AM	ADDRESS	34.09487	-118.22707	FIRE ALARM SYSTEM WHICH INCLUDES 14 FIRE ALARM DEVICES AND 1 NEW PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6140	13041-20001-33303	5260 N BELLINGHAM AVE	91607	2	171B165   327	2347020015	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			02/26/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.1663	-118.39912	supplemental to original application. plan check for upgrade in house meter and main pull section. new pull section per DWP requirements. this is to add the service and pull section to master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6141	18041-10000-12288	1525 E 103RD ST	90002	15	091-5A213 180	6048012931	PF-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM			Corrections Issued	04/05/2018 12:00:00 AM	ADDRESS	33.94341	-118.24719	PC FOR TI TO A FUTURE COUNSELING CENTER IN ABANDONED FIRE STATION (CITY OWNED BUILDING) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS.  TOTAL AFFECTED AREA 4650SQ.FTB#18016-10000-10098	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6142	14041-20000-11996	16902 W KESWICK ST	91406	6	186B133   109	2203013013	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.20957	-118.50162	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL TRANSFORMERLESS INVERTER. SYSTEM SIZE: 4.25 KW DC.(17) CANADIAN SOLAR CS6P 250(1) POWER ONE AURORA PVI 3.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6143	18041-10000-11518	400 W 30TH ST	90007	9	120A203    86	5122018033	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.02393	-118.27577	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6144	17041-10000-22317	6348 W FOOTHILL BLVD	91042	7	198B205   113	2572009018	(Q)C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.2423	-118.26963	PC for Fire alarm with 1 annunciator and 1 notification device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6145	11041-20000-08416	4618 W MELROSE AVE	90004	13	141B193   579	5520002032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	PIN	34.08339852	-118.30132095	"TI in a Coin Laundry. Existing panels & service. Addition of 6 ckt for new dryer. Per applicant request, plan check for power only.  ""COMPLY WITH DEPARTMENT ORDER effective date02/15/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6146	18041-20000-30758	11025 N FULLBRIGHT AVE	91311	12	210B113    97	2707026009	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.27055	-118.57724	Plan check for  PV roof mounted system, system size: 15.12 AC CEC with 52 PV modules and 1 inverter(11.4kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6147	13041-10001-27126	8900 N MOORCROFT AVE	91304	12	195B101    92	2004023008	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.23252	-118.60978	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. STANDARD PLAN.  SYSTEM SIZE: 10 kW.(40) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6148	17041-10000-24070	12568 W TIBBETTS ST	91342	7	228B161   754	2580004012	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.31876	-118.40694	Install new rooftop solar system 17.2kW AC, (48) AC modules, with new 125A subpanel. rooftop solar*************************$0 fee due to Senate bill 1222 sq.ft	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6149	16041-20002-29066	19850 W LINNET ST	91364	3	171B113    96	2164002013	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2016 12:00:00 AM			PC Approved	09/06/2016 12:00:00 AM	PIN	34.1672967	-118.56561045	FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.9.6.2016 - Plan check for modifications to approved set. Change panel layout on roof, and location of inverters. No change to module or inverter count/models. Changes clouded.======Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system.Each module has a 300W power optimizer. (29) 285W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6150	16041-20001-23299	5106 N MAMMOTH AVE	91423	4	171B157   798	2269001013	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.16326	-118.4323	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.58 kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6151	19041-10000-35915	5257 N LEMP AVE	91601	2	171B169   268	2348006038	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.16649	-118.3846	NEW 5.28KW ROOF MOUNTED PV SYSTEM WITH 16 PV PANELS & 16 ENPHASE MICRO INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6152	14041-10000-24954	224 E 6TH ST	90014	14	127-5A211 118	5148022011	C2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.04402	-118.24838	Change of use from retail to office.  Mental health care office TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6153	12041-20000-11111	10100 W SANTA MONICA BLVD 5th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/15/2012 12:00:00 AM			PC Approved	05/15/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	Tenant improvement for existing office space. Plan check for energy and emergency lighting. Commercial high-rise. 21,043 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6154	17041-20001-45388	10131 N LEMONA AVE	91345	7	204B149   346	2660018005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.25471	-118.4588	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.6kW ungrounded system. (20) 305W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6155	14041-20000-12487	18144 W CHASE ST	91325	12	192B125   335	2786012004	RA-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.22444	-118.52879	PV1. ROOFMOUNTED SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 7.75KW DC(31) ENPHASE M215 INVERTER(31) SOLAR WORLD SW250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6156	14041-10001-03334	21001 W SHERMAN WAY	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM			Corrections Issued	05/19/2014 12:00:00 AM	ADDRESS	34.20126	-118.59094	Plan check for 'Planned Parenthood' medical facility, consisting of patient care area (multiple exam rooms for medical and clinical care) . Projected area in lighting scope of work is approx. 2218 sf, with emergency lighting. Not an OSHPD facilitiy per applicant.((((((((    single line changed design changed ,  new circuits , and D.P     5-13-14   M.Z  )))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6157	17041-20000-40304	9667 N RESEDA BLVD 200	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.24627	-118.5363	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR JUICE BAR WITH RETAIL. 1509 SQFT.Electrical permit fees collected under application #17041-70000-40997 and #17041-70001-40997. BUILDING PERMIT #  17016-30000-29229	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6158	15041-20000-21455	11122 N CLAIRE AVE	91326	12	210B121   280	2718002005	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.27237	-118.54756	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (26) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6159	16041-20000-45761	19338 W SATICOY ST	91335	3	186B117   222	2116015039	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Apartment			12/30/2016 12:00:00 AM			Reviewed by Supervisor	02/02/2017 12:00:00 AM	ADDRESS	34.20822	-118.55495	new 4 story apartment building.  1200 amp service. plan check for power and energy.B#16010-20000-05635	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6160	18041-10000-08889	1648 N KINGSLEY DR	90027	13	148-5A195 129	5544015010	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	08/16/2019 12:00:00 AM		Issued	08/16/2019 12:00:00 AM	ADDRESS	34.10129	-118.30303	Plan check for PV roof mounted system. System size: 18kWac with 75 moduels and 2 inverters(5.2kW) and 1  inverter (7.6kW) conncted to MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6161	15041-20001-35195	8635 W 3RD ST STE 800-885	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.07373	-118.38073	***Adding the brach ckt count per inspector ref.***Permit under 15041-10000-35195TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK IN THE 8TH FLOOR ONLY.BUILDING APPL# 15016-10000-03698FIRE ALARM VARIANCE ON FILE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6162	14041-10003-23116	138-140 N SAN FERNANDO ROAD	90031	1	139-5A219 122	5447014024	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.07531	-118.22164	02/03/2016Changes to an approved set of plans. Note changes on delta 5 only. Changes include the location of the electrical equipment and configuration of the floor plan. (((Change to approved set by rerouting feeder for panel P2 with new location. All changes are under delta-3 and 4 only.)))(((PC for power. Upgrading  existing  service  to 800 amp 120/240v 3 phase.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6163	19041-20000-42607	5360 N RHEA AVE	91356	3	171B121    86	2161009005	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.16855	-118.54187	Plan check for PV roof mounted system, PV system size: 8.58KW DC, 8.19KW AC with 26 PV modules and 26 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6164	17041-10000-15757	5028 S DENKER AVE	90062	8	111B193  1269	5016034011	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	33.99733	-118.30441	PV INSTALLATION OF A NEW 7.6KW AC SOLAR SYSTEM ON A SINGLE FAMILY HOUSE( WITH OPTIMIZER)(31) MODULES: HANIWHA Q PEAK-G4.1300(1) INVERTER: SOLAREDGE SE7600A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6165	15041-10000-27526	7191 W FORMOSA FUSION CT	90046	5	141B181  1715	5525003040	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08566	-118.34571	PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6166	14041-20001-01009	13645 1/2-1/4 W FOOTHILL BLVD	91342	7	222B157    79	2509015035	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.30793	-118.43064	suppl. for change in design. SCOPE OF WORK INCLUDES NEW 600A SERVICE AND DISTRIBUTION. PC FOR POWER ONLY. ENERGY HAS ALREADY BEEN PLAN CHECKED UNDER ORIGINAL APPLICATION. PERMIT FOR REMAINING ITEMS WILL BE COVERED UNDER THIS APPLICATION UNDER INSPECTION FEE PERIOD. ORIGINAL PERMIT 14041-20000-01461.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6167	17041-20000-00347	13129 W BLOOMFIELD ST	91423	4	165B157   431	2375001067	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.14944	-118.41912	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6168	14041-10000-02374	7435 W PALO VISTA DR	90068	4	156B177   338	2427014007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Expired	04/27/2016 12:00:00 AM	PIN	34.1236675	-118.35627136	PV1, Install 7.5 KW DC roof-mounted solar array on a TWO story house, interconnect with existing service panel. (1)Transformerless inverter: SOLAREDGE SE6000A-US-ZB-U(30) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6169	13041-10000-25148	10511 N ANDORA AVE	91311	12	207B101   219	2723007012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	ADDRESS	34.26133	-118.60951	revision to approved set of plans. cutting system in half due to other side building not being approved. clearances are still the same from last tim. INSTALLING PV SYSTEM TO SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 13.8KWDC. [INVERTER: SUN POWER SPR-11401F-1 UNI] [PV MODULE: SUN POWER SPR327NE-WHT-D]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6170	10041-20000-10957	8243 N SEPULVEDA BLVD	91406	6	192B145   434	2654036024	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys			1174.06, 1275.20	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	PIN	34.22099029	-118.46819218	T.I. for Seven-Eleven.  Install new panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6171	11041-20000-24064	11333 N SEPULVEDA BLVD	91345	7	213B145   166	2664001801	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1092.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	01/03/2013 12:00:00 AM	ADDRESS	34.27646	-118.46863	fire alarm system new medical office three stories	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6172	13041-10000-30753	3721 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.01899	-118.35583	REMODEL DENTAL CLINIC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6173	12041-10000-10274	14530 W NORDHOFF ST	91402	7	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.23519	-118.44861	PLAN CHECK FOR NEW FIRE ALAM SYSTEM FOR WALMART.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6174	18041-20001-48783	11937 N RICASOLI WAY	91326	12	216B109   332	2701085013	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Issued	04/02/2019 12:00:00 AM	ADDRESS	34.28986	-118.58501	04/02/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Equipment has been relocated and battery back-up interconnection configuration has been revised.*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 15.925 kWdc/14.3 kWac-CEC and consists of (2) inverters, (49) modules, (2) battery back-up units, and (2) load centers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6175	15041-10000-24059	1500 W PACIFIC COAST HWY Bldg E	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 5 unit apartment with garage, Typev VA construction. 100 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6176	11041-20000-01288	6420 W WILSHIRE BLVD #1700	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I. to a high rise building of the 17th floor in the office area.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6177	15041-10000-40938	3951 W INGRAHAM ST 1-13	90005	10	132B193   120	5092030023	R4P-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.06079	-118.31303	NEW FIRE ALARM SYSTEM 120 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6178	13041-10000-11969	380 S LOS ANGELES ST	90013	14	129A213   200	5148002018	C2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	10/16/2014 12:00:00 AM		Issued	10/16/2014 12:00:00 AM	ADDRESS	34.04743	-118.24555	Addition to existing building.  2 stories.  Addition to be supplied wtih new service and distribution system.  Addition contains basement floor for storage, retail spaces on ground floor, and office and parking on 2nd floor.Applicant submitted one set of plans for 2 separate buildings.  Other bldg is 215 E 4th St under application 13041-10000-11964.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6179	19041-20000-31641	14615 W ISLA VISTA DR	91402	6	201B149   886	2650019059	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.24756	-118.45094	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON A NEW SFD. SYSTEM SIZE IS 3.15KW DC/2.835 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6180	15041-20001-09635	12682 W SANDHILL LANE 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/01/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	33.97708	-118.41507	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: SYSTEM SIZE: 1.38KW   LANE # 26 MODULES(1) 3.0 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6181	19041-20000-45283	910 S SANTA FE AVE	90021	14	123A217   109	5166004024	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/25/2021 12:00:00 AM	ADDRESS	34.03232	-118.2297	Power and lighting for commercial tenant space.  Plan check for energy.B#19016-10000-36730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6182	17041-10000-09292	241 W WATCHORN WALK BERTH-32 & 34	90731	15	009B201     4	7440036906	M2, [Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	33.72201	-118.28186	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 75350 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6183	15041-20000-40133	824 S LA BREA AVE	90036	4	132B181   340	5084003047	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM			PC Info Complete	12/01/2015 12:00:00 AM	ADDRESS	34.05985	-118.34471	Plan check for T-24 only for T.I. restaurant, change of use from retail to restaurant. Total  space 936 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6184	17041-10000-19443	15942 W ARMINTA ST	91406	6	189B141   171	2206008005	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	34.21377	-118.48086	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6185	18041-20000-06397	7165 W SUNSET BLVD	90046	4	147B181   612	5548011034	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.09814	-118.34615	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area  = 1,056 sq. ft.Note: Building permit has been issued under 17016-30000-13263	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6186	09041-20001-22339	18700 W VENTURA BLVD Yogaworks	91356		174B121   601	2161008001							Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM			PC Approved	06/23/2010 12:00:00 AM	ADDRESS	34.17045	-118.54081	Plan check for revision to approved plans. All changes are clouded.  Changes consist of lighting and adding branch circuits. First time tenant for a yoga studio.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6187	12041-20000-18604	4342 N BABCOCK AVE 1-9	91604	2	165B161   399	2375002026	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			08/08/2012 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.14982	-118.40612	Plan check for power and energy. New apartment. 4855 sqft indoor and 2237sqft outdoor. 9 unit apartment building. Not a methane hazard site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6188	12041-20000-01119	11630 W MORAGA LANE Main-House	90049	5	144B145   268	4368002008	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Expired	11/18/2014 12:00:00 AM	ADDRESS	34.08705	-118.46821	Plan check for new single family dwelling and for new guest house.  The guest house will be permitted on application number 12041-20000-04868.  This application will be the permit for the main house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6189	16041-10000-36208	5707 W MELROSE AVE	90038	13	141B189   276	5534036016	C2-1D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.0836	-118.32481	TITLE 24 ONLY FOR EXISTING LOW RISE BUILDING. TI INCLUDING NEW LIGHTING INDOOR AND OUTDOOR. TOTAL SQ. FT.  18018	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6190	18041-10000-35091	9140 N HASKELL AVE	91343	12	198B141   605	2671012018	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Issued	09/14/2018 12:00:00 AM	ADDRESS	34.23705	-118.47614	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6191	17041-20001-22150	22115 W CALIFA ST	91367	3	177B101   279	2146015021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.17776	-118.6082	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with an AC coupled battery backup system, SFD.6.6kW ungrounded system. (23) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6192	13041-10000-02648	13996 W WEIDNER ST	91331	7	207B153   761	2618007007	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.2621	-118.43821	PHOTOVOLTAIC SYSTEM FOR SINGLE STORY SINGLE FAMILY DWELLING. PV1 SYSTEM. TOTAL SIZE OF 3.67KW. 17 TOTAL UNITS. MICROINVERTER ENPHASE M215-60-2LL-S22. PANEL - REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6193	17041-20000-19660	11500 W CANTON DR	91604	2	159B169   378	2377016014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.13274	-118.38388	"""0$ permit fees due to senate bill 1222""Plan check for roof-mounted solar pv system with AC coupled battery backup system.10.4kW ungrounded system. (37) 325W pv modules. (2) 5kW Tesla Powerwalls."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6194	12041-10000-18034	11057 N BALBOA BLVD	91344	12	210B133   507	2696017023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM			PC Approved	08/02/2012 12:00:00 AM	ADDRESS	34.27156	-118.50242	New exterior lighting to an existing commercial building.  Load is 225.1 Amps per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6195	15041-10003-22097	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Changes to approved set of plans . Note, changes under delta 11 only. Scope of work includes the addition of the lab panels and space. Total sq. ft. 29472. The permit fee is paid for application 15041-10003-14660	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6196	11041-10000-25053	6060 N FIGUEROA ST	90042	1	151-5A231 413	5492024015	[Q]C4-2D, [Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.00	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.11176	-118.18797	Plan check T24 Energy/Emergency for dining room and exterior lighting TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6197	13041-20000-01005	21650 W OXNARD ST 11TH FLR	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	TI AT OFFICES ON 11TH FLOOR. NON BEARING PARTITIONS, MILLWORK AND SUSPENDED CEILING. CREATE NEW FITNESS AREA FOR TENANT USE ONLY.  22539 SQ.  Plan check for T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6198	15041-20001-04700	1649 W 58TH ST	90062	8	108B193  1171	5003030027	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	33.98982	-118.30623	Expedited per customer request.PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel. (22) Sunpower 327W Modules(2) PVI 3.8 TL Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6199	19041-10000-33694	5526 N FIGUEROA ST	90042	1	151-5A227 306	5468026001	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	04/01/2020 12:00:00 AM		Permit Finaled	08/14/2020 12:00:00 AM	ADDRESS	34.10819	-118.19525	FULL PLAN A NEW 600A SERVICE 3PHASE 4WIRE, A NEW 600A SWITCHBOARD AND A 200A SUBPANEL. TOTAL AFFECTED AREA IS 2859 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6200	16041-20000-12193	5046 N FULTON AVE	91423	4	171B157  1220	2358006027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.16276	-118.42227	PV1.  Install 3.8 kW roof-mounted PV system.  (10) modules with 3.8 kW rated inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6201	19041-10000-01920	21121 W VANOWEN ST 1-101	91303	3	183B105   944	2138022019	(WC)RIVER-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			01/16/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	09/07/2021 12:00:00 AM	ADDRESS	34.19391	-118.59348	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 7 STORY MIXED USED BUILDING 101 DWELLING UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6202	14041-10001-16876	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			06/04/2015 12:00:00 AM			PC Info Complete	08/19/2015 12:00:00 AM	ADDRESS	34.04166	-118.26677	Design change. Pc for power and energy. per high fee for the original fee the supplemental created. ALL PERMIT/INSPECTION FEES ARE COVERED UNDER THE MASTER APPLICATION. THIS IS A PLAN CHECK ONLY APPLICATION.{{{Plan check for power and lighting.  Total area = 1,190,061 sq. ft.New high rise multi-use project with 9 floors of parking, retail on the ground floor, and two 36 story towers accomidating 652 residential units.Submittal fees are per applicant count - fees to be verified later.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6203	12041-20000-18521	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	T.I. to a high rise building partial of 16th floor, suite 1688.  Install general/emergency lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6204	10041-10000-15625	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			08/10/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	33.96577	-118.42406	title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6205	16041-10000-34437	5735 W ADAMS BLVD	90016	10	123B173   825	5048005039	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.03262	-118.36814	"T-24, PC for energy only. Change of use from meat distribtion plant to office & TI. Scope inlcudes new lights and receptacles. Total affected area is 10270 Sq. Ft. ""Comply with Department order effective date 6/30/2016. Permit will expire 30 days after issuance date."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6206	19041-20000-48490	1580 N STONE CANYON ROAD	90077	5	147B149    41	4370015015	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.10286	-118.45468	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 3.11 KW DC/2.88 KW AC. SCOPE OF WORK CONSISTS OF 9 PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6207	17041-20000-14391	21757 W ERWIN ST	91367	3	177B105   125	2146029018	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.18306	-118.60312	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 2765.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6208	14041-20000-24306	18701-18729 W REDWING ST	91356	3	174B121   812	2161026005	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.16963	-118.54066	NEW CONSTRUCTION FOR 15 APARTMENT UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6209	18041-20000-39950	5100 E RANGE VIEW AVE	90042	14	156A225    54	5479027016	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.12353	-118.20385	Plan check for a PV1 roof-mounted PV system. System size is 7.2 kWdc/6.5 kWac-CEC and consists of (1) inverter, (24) modules, (1) load center, and (1) back-up battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6210	12041-20002-27401	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	this application was in error. disregard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6211	19041-20000-50843	14350 W OXNARD ST	91401	4	177A151   106	2245017003	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	06/28/2022 12:00:00 AM	ADDRESS	34.17921	-118.44614	Plan check for Title 24 Energy for new lighting. Total area: 1267 sq ft. B#18016-20000-22203	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6212	14041-10000-14588	950 W JEFFERSON BLVD	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.02484	-118.2869	permit to be pulled at EPC counter only. Plan check for energy only. JEF Office Conversion 2014. ti office to office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6213	18041-20000-00858	7320 N HILLSVIEW CT	91307	12	186B089   513	2027047004	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.20479	-118.65146	Note: $0.00 permit fee due to CA Senate Bill 1222pv1install roof mounted pv system sized 10kw interconnected with msp with three tesla battery back up.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6214	17041-10000-46586	9733 W VENICE BLVD	90034	5	120B165   932	4313015047	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.02434	-118.39776	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6215	12041-20000-31232	120 E 5TH ST	90013	14	129A211   218	5148019001	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM			PC Approved	12/31/2012 12:00:00 AM	ADDRESS	34.04611	-118.24798	Change to lighting on an existing low-rise retail building.  Not a 1st time tenant, load is 80 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6216	11041-10001-22040	5115 W MELROSE AVE	90038	13	141B193   538	5535015014	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			10/14/2011 12:00:00 AM			Corrections Issued	10/24/2011 12:00:00 AM	ADDRESS	34.08364	-118.31165	Service upgrade to 800 Amps for two existing Apt Buildings (5101 & 5115 Melrose).Add one new AC unit in each Apartment.  (5101==> 20 Units ==> 11041-10000-22040 & 5115 ==> 22 Units  ==>  this application.)  Upgrade the feeder to each unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6217	13041-10000-22378	8813 S SEPULVEDA BLVD	90045	11	096B165   974	4122035029	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	33.9568	-118.39645	APPLICATION IS FOR PLAN CHECK AND PERMIT FOR TENANT IMPROVEMENT. TITLE 24 PLAN CHECK ONLY. 1534 SQFT EMERGENCY LIGHTING. 1 STORY BUILDING. CHASE BANK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6218	13041-10000-20987	11606 W CANTLAY ST	91605	2	186B169   983	2316029005	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.20241	-118.38477	PV1.  Install 5.145 kW DC roof-moutned solar array, interconnect with main service panel.  {Aurora PVI-3.6-OUTD-S-US} {21 modules: Trina Solar TSM-245PC05/PA05.18}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6219	13041-10000-35796	2595 S HOOVER ST	90007	8	123A201    42	5055022034	C4-1VL-O, QC1.5-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.03206	-118.28429	PLAN CHECK FOR POWER AND ENERGY FOR EW DEVELOPMENT INCLUDING 46 RESIDENTIAL UNITS, 3 & 4-STORY AND +/- 7,000 SQ.FT. OF COMMERCIAL USE.BUILDING P # 1301010000-04326	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6220	18041-10000-42822	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	T24 ONLY FOR TENANT IMPROVEMENT TO RESTROOMSBUILDING PERMIT #18016-10000-32967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6221	18041-10000-26522	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	33.96577	-118.42406	PC FOR TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING FOR POWER AND ENERGY (LOYOLA UNIV).SCOPE INCLUDES NEW CONNECTED LOAD >400A. SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL CONNECTED AREA 20694 SQ.FT  B# 18016-10000-19140	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6222	13041-20000-28241	111 N LA BREA AVE 3RD FLOOR	90036	5	138B181   780	5513002002	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.07395	-118.34423	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON THE 3RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6223	19041-20001-10429	11705 W VENTURA BLVD	91604	2	162B169   335	2368006025	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	ADDRESS	34.14159	-118.388	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. CHANGES MADE TO LIGHTING FLOOR PLAN, LIGHTING FIXTURE SCHEDULE, POWER PLAN, AND T24 SHEETS. CHANGE IN LIGHT MODELS, RECEPTACLE NUMBERS, LIGHTING NUMBERS, T24 INSTALLED WATTAGE, AND LIGHT INPUT WATTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6224	16041-20000-28605	9759 N MERCEDES AVE	91331	6	201B153   439	2645025026	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.24807	-118.43716	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 3kW ungrounded system.(12) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6225	13041-10000-34626	4774 W ADAMS BLVD	90016	10	123B181  1009	5057010015	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.03237	-118.3444	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 738 SQ FT. REPLACING TOTAL OF 2 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6226	14041-20000-16032	7940 N VAN NUYS BLVD #2A	91402	6	189B149   634	2212028020	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.21548	-118.44851	T.I. to existing restaurant.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6227	13041-10000-12567	1459 N VIA CRESTA	90272	11	132B125    15	4420040010	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.05692	-118.53674	PV1 12.25KW ROOFMOUNT. NONSTD. XFRMRLESS+ OPTIMIZER. 2 solaredge SE6000A-US inverters  and 50 trina TSM-245pc05 modules and corresponding optimizers .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6228	19041-20001-40403	4921 N ABBEYVILLE AVE	91364	3	168B093    85	2074029004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.15947	-118.63235	Plan check for 12.16 kW DC roof mounted PV system [38 modules with 7.6 kW rated inverter] and 9.8 kWh energy storage system with 60A backup load center.  Master permit issued under 19041-90000-40403 is for ESS component of project scope.  Associated PV permit previously issued under 19041-90000-37343.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6229	14041-10002-26245	843-845 N SEWARD ST	90038	4	141B185    46	5533024021	MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM			PC Approved	09/27/2016 12:00:00 AM	ADDRESS	34.08649	-118.33326	09/27/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include replacing incandescent lighting fixtures with LED fixtures, replacing time clocks with motion sensors, and replacing hard wired dimmer switches with wireless dimming controls. Note: Permit is paid under PCIS#14041-10001-26245(((((((((((06/07/16Changes to approved set of plans. Changes include replacing/removing/adding lighting fixtures on floor plans. Changes are not under a delta number since lighing fixtures have been replaced with completely different fixture type from original set.  (((((Plan check for energy only 2013  Standards.  Corrections issued for 9/23/2014. Approved 11/12/2014.  Renovation of existing 2566 sq. ft. office building (ground floor) and addition of 1690 sq. ft. (second floor). Indoor and outdoor lighting. BLDG#14014-10-04162. Changes on plans include added controls for outdoor and clarifying information on forms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6230	19041-20002-11124	5031 N FAIR AVE	91601	2	171B173  1095	2353011037	R4-1	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			PC Approved	09/10/2019 12:00:00 AM	ADDRESS	34.1617	-118.37478	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET CLOUDED DELTA 1 CHANGES ONLY. CHANGE TO SINGLE LINE, CHANGE TO FEEDER SIZES AND LOAD CENTER LOCATION. ALSO ADDED JUNCTION BOXES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6231	15041-10000-25068	1402 W 37TH ST	90731	15	006B193    52	7470024012	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Expired	08/29/2017 12:00:00 AM	ADDRESS	33.71538	-118.30852	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6232	10041-20000-17030	2823 S FLOWER ST	90007	9	121-5A203 195	5123019027	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	12/13/2010 12:00:00 AM	ADDRESS	34.02546	-118.27634	lighing and power in office. energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6233	16041-10000-17626	1620 W SUNSET BLVD	90026	13	139-5A209 181	5404018013	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.07687	-118.25812	TI TO (E) TAKE OUT RESTAURANT.  NEW CONNECTED LOAD < 400A. INSTALL NEW LIGHTS ON SERVICE AND CUSTOMER AREA ONLY.  PC FOR T-24. TOTAL AREA: 500 SQ.FT.B# 16016-10000-07521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6234	15041-10000-00849	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Office TI by remodeling an existing westfield security office in topanga mall.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6235	15041-10001-03688	2435 N CREST VIEW DR	90046	4	153B169   273	5564015022	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.11606	-118.3896	Supplemental application for expedite fees.Installation of roof mounted solar PV array.  Total system size = 6.6 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6236	14041-20000-10581	1999 S AVENUE OF THE STARS 26th floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI to 26th floor of existing commercial highrise building.  Title 24 plan check for changes to lighting system.FULL PLAN CHECK IS REQUIRED. TOTAL NEW/REVISED/RECONNECTED LOAD EXCEEDS 400AMPS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6237	16041-10001-19487	8900 N DE SOTO AVE # 101	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for powwer only for addition of the builidng. Note: Energy plan check was plan check under: 16041-10000-19487	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6238	19041-10000-42506	1999 S AVENUE OF THE STARS 30th floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLAN CHECK FOR TITLE 24 ONLY FOR CORRIDORS ONLY ON 30TH FLOOR. TOTAL AFFECTED AREA = 1970 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6239	14041-10000-21997	11050 W MAGNOLIA BLVD	91601	2	171B173   611	2353005001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.16478	-118.3723	Plan check for power and lighting.  Total area = 1,418 sq. ft. (outdoor) and 3,620 sq. ft. (indoor)New electrical service (800 A), 3 subpanels, recepticles, interior and exterior lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6240	16041-20001-24357	11250 N ZELZAH AVE	91344	12	210B129    90	2711018002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM			PC Approved	07/18/2016 12:00:00 AM	ADDRESS	34.27527	-118.52319	RSES expedited plan check fee per applicant request.  PV1.  Installation of 8.59 kW AC roof mounted PV system.  (35) modules with 10 kW rated inverter with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6241	15041-10001-27014	12700 W MILLENNIUM #46	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	33.97639	-118.41499	expedited fees for roof mounted pv system. (((Installation of roof-mounted solar PV, AC, system. (6) modules, (1) subpanel, total size 1.5Kw. Application is for plan check only, permit fee is paid under 15041-90000-26267.(6) sunpower modules SPR-X20-250-BLK-B-AC)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6242	13041-20000-20348	12732 N HUNNEWELL AVE	91342	7	222B157   566	2525002018	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Expired	08/26/2015 12:00:00 AM	ADDRESS	34.30164	-118.41984	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.595KW. 31 PANELS AND 2 INVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6243	19041-20000-36165	16706 W KNOLLWOOD DR	91344	12	216B137   192	2609018004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.28909	-118.49433	Plan check for PV roof mounted system, PV system size: 10.08KW DC, 9.18KW AC with 32 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6244	14041-20000-17738	1030 N RIVAS CANYON ROAD PV 1	90272	11	129B129   349	4409005009	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	ADDRESS	34.04966	-118.51575	9.810 KW ROOF MOUNTED PV SOLAR SYSTEM, this is plan check for transformerless inverter system. 2 inverters. total 10kw AC. original permit issued under application 13041-20000-20253	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6245	16041-10001-22378	1624 W 59TH PL	90047	8	105B193   279	6002014010	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2016 12:00:00 AM			PC Approved	07/28/2016 12:00:00 AM	ADDRESS	33.9866	-118.3055	PC only. Change of solar panel layout. ((((PV1, rooftop solar installation 3kW AC system.   (12) RNG-250D    (12)ENPHASE M250)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6246	17041-20002-05835	4664 N DEL MORENO DR	91364	3	168B113   418	2174019014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	34.15491	-118.57526	4/25/2017Changes to an approved set of plans.  addition of AC disconnect.This is plan check only.(((PV1 .  Install 3.9 kW roof mounted grid tied PV system.  (15) modules with microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6247	13041-10000-26815	5353 N MECCA AVE EV2	91356	3	171B125    30	2161016027	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.16869	-118.53769	EV-2. PLAN CHECK FOR INSTALLATION OF ELECTRICAL VEHICLE CHARGING INFRASTRUCTURE FOR EXISTING WALGREENS.  NEW 400A SERVICE SUPPLYING COMMUNICATION CABINET, LEVEL 1, LEVEL 2, AND LEVEL 3 EV CHARGERS.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
6248	16041-10000-22001	839 W ADAMS BLVD #1-18	90007	1	123A201   159	5124024009	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Apartment			06/22/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.03047	-118.28071	Install New F.A system on (E) Senior residence apartments.     (4) panels    (48) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6249	12041-20000-17454	333 S GRAND AVE	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.05271	-118.25179	T.I. to a high rise building on 1st floor in the restrooms.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6250	14041-20002-04064	14958 W SEPTO ST PV1	91345	7	201B149   112	2647010042	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.2508	-118.45843	changes to approved set of plans. addition of a disconnect and revised service interconnection. no changes in load.$0 plan check fee due to senate bill 1222 from 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6251	15041-10000-25594	9934 N TERHUNE AVE	91040	7	201B177    57	2542013030	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.25099	-118.36361	PV1 PC OVER COUNTER, INSTALLATION OF ROOF MOUNTED SOLARY SYSTEM FOR A SINGLE FAMILY HOME. (1) 3.8KW INVERTER, (10) MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6252	17041-20000-41450	16311 W VENTURA BLVD Ste 580	91436	5	168B137   359	2260009038	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			Verifications in Progress	03/02/2018 12:00:00 AM	ADDRESS	34.15723	-118.48856	Medical clinic TI in (E) multiple-occupancy commercial highrise building with critical care areas/operating rooms.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6253	13041-10000-05757	11520-11532 W SAN VICENTE BLVD	90049	11	129B145   102	4265004043	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Approved	05/16/2013 12:00:00 AM	ADDRESS	34.05292	-118.46124	pc for energy only. less than 400 A per applicant. core/shell stuff only. TENANT IMPROVEMENT/STRUCTURAL UPGRADE FOR EXISTING 2-STORY OFFICE;  9,064 S.F.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6254	13041-10000-09078	2679 N ZORADA DR	90046	4	153B177    81	5569020024	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.11887	-118.36465	PV1 SINGLE FAMILY DWELLING. PLAN CHECK FOR NEW ROOF  MOUNTED PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 9.2 KW. USING TRANSFORMERLESS INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6255	17041-20001-25650	7675 N SAN FERNANDO ROAD	91505										Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	34.20826	-118.35549	Supplemental for lost set of approved plans.  Plan review only.  (((ti to an existing commercial building.  adding new lighting new controls to new panel, newly connected load < 400 amps.  plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6256	15041-20000-20849	555 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.13776	-118.3584	Plan check for fire alarm. Addition 7 devices to existing fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6257	19041-20000-13005	17052 W PAULETTE PL	91344	12	219B133   337	2608023008	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Issued	04/10/2019 12:00:00 AM	ADDRESS	34.29774	-118.50436	Plan check for PV roof mounted system, system size: 12.96KW DC, 11.52KW AC with 36 PV Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6258	16041-10000-23606	15435 W RAYEN ST	91343	7	195B145   639	2654003038		North Valley				1174.05	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.23202	-118.46881	T-24, PC for energy only. Interior remodel - convert (e) storage room to enlarge the (e) mens and women restrooms. Scope includes new lights and controls for restrooms. Total affected area is 698 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6259	18041-20002-12897	12744 N SAN FERNANDO ROAD Bldg 2	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Approved	09/27/2018 12:00:00 AM	ADDRESS	34.30155	-118.46112	"09/27/2018 Changes to an approved set of plans. All changes have been clouded. Bathroom fixtures have been replaced with a like-wattage fixtures and dimming system has been modified.08-23-2018 Changes to an approved set of plans. Changes include lighting layout configuration, remove lighting fixture ""C"", update photometrics calculaiton . Changes has been cluded."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6260	16041-10001-24790	13536 W BEAVER ST	91342	7	225B157   574	2510020018	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.3126	-118.42749	expedite feesPV1. NEW SOLAR SYSTME ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.0KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6261	16041-10001-24938	23369 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	34.15853	-118.63421	10/07/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include updating the panel schedule to reflect what is on the field.Note: Permit is paid under PCIS#16041-10000-24938((((((PC FOR ENERGY ONLY. CHANGE OF USE FROM TAKE OUT ICE CREAM PARLOR TO TAKE OUT JUICE BAR. TOTAL AREA 1574 SQ FT. B # 16016-10000-16370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6262	16041-10000-35580	5121 N SAN FERNANDO ROAD WEST	90039	13	165B205   119	5593011043	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.1457	-118.27194	T-24, PC FOR ENERGY ONLY. TI TO AN EXISING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 21200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6263	18041-10003-07688	7540 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	33.94052	-118.42863	DELTA 2 CHANGES TO AN APPROVED SET TO REMOVE UPS-102 (45KVA) AND TO ADD TWO NEW CIRCUITS TO PANEL URP-102. NO OTHER CHENGES APPROVED UNDER THIS DELTA. PC for powery for LAX delta airlines high bay hangar with one story of office space. Installing new 3000A service, new service quipment, new panels and circuits.    Title 24 and lighthing is under a separate permit MZandi  . B# 18010-10000-00614.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6264	16041-10000-30082	1908 N MONON ST	90027	4	150B201  1004	5433007026	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Expired	05/08/2024 12:00:00 AM	ADDRESS	34.10569	-118.27951	PV ROOF MOUNTEDPC FOR PV SYSTEM WITH BATTERY STORAGE. USING 17 MODULES OF AC PV MODULES. 6.1KW AC TOTAL. USING BATTERY STORAGE INVERTER SYSTEM. INSTALLING LOAD CENTER FOR OPTIONAL STANDBY LOADS. INSTALLING PV SUBPANEL FOR COMBINING AC MODULE CIRCUITS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6265	18041-10000-14541	7023 N RESEDA BLVD	91335	3	183B125   494	2126008011	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Issued	04/20/2018 12:00:00 AM	ADDRESS	34.19835	-118.53625	REPLACE INTERIOR  METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6266	15041-20000-01916	3434 S GRAND AVE OFFICE 120	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Info Complete	01/22/2015 12:00:00 AM	ADDRESS	34.01912	-118.27658	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN OFFICE 120.  TOTAL SQUARE FOOTAGE 586.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6267	15041-20000-02915	14752 W ALBERS ST	91411	4	174B149  1103	2249015002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.17012	-118.45489	PV1. Install roof mounted solar system sized 7.6 kW. Interconnected with main service panel.(24) Sunpower E20/327 Modules(2) Sunny Boy 3800 TL Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6268	13041-10000-21324	9910 N VANALDEN AVE	91324	12	201B121    78	2729005008	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.25044	-118.54906	PV1.  Install 10.464 kW roof-mounted solar array, interconnect into main service panel.  {	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6269	13041-20000-15315	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	update single line diagram	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6270	16041-10000-16435	2470 S WESTERN AVE	90732	15	009B193   126	7460004007	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2973.00	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	33.72319	-118.31224	T-24, PC FOR ENERGY ONLY. TI TO EXISTING RESTAURANT (ROCK'N JUICE). SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND ONE NEW 100 SUBPANEL. TOTAL AFFECTED AREA IS 1179 SQ. FTNOTE: PERMIT PAID UNDER PCIS#15041-10000-30058.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6271	15041-10001-33955	5210 W OLYMPIC BLVD 1-8	90036	10	132B181   703	5084011018	R3-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Apartment			11/02/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.05691	-118.34296	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. RELOCATED PANELS TO 1ST FLOOR, RECHECKING VOLTAGE DROPS AND AIC RATINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6272	14041-20000-06855	10940 W VICTORY BLVD	91606	2	180B173   884	2414001002	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.18652	-118.36952	FIRE ALARM FOR ADULT DAYCARE CENTER. 1 NEW FIRE ALARM CONTROL PANEL AND 27 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6273	14041-20000-33016	550 S HOPE ST SUITE 1950	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM			PC Approved	11/26/2014 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. NO CHANGE IN OCCUPANCY, NEWLY CONNECTED LOAD < 400 AMPS PER APPLICANT. 5860 SQFT, EMERGENCY LIGHTING. 19TH FLOOR. SUITE 1950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6274	16041-10000-05756	3435 W WILSHIRE BLVD 7TH FLR	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.06194	-118.29866	T-24, PC FOR ENERGY ONLY. TI TO A PORTION OF THE 7TH FLOOR OF AN OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2739.NOTE: Investigation fee included	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6275	14041-20001-00504	7839 N VARIEL AVE	91304	3	189B105   380	2109017007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.21319	-118.59299	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6276	14041-10000-01814	913 S SYCAMORE AVE	90036	4	132B181   517	5084004012	R2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.05848	-118.34447	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 11328 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6277	19041-20000-48289	19228 W VENTURA BLVD	91356	3	174B117   358	2163017022	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.17244	-118.55221	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. SCOPE OF WORK CONSISTS OF (1) FIRE ALARM PANEL AND (70) FIRE ALARM DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6278	18041-20000-17787	17608 W LEMAY PL	91406	6	180B129   382	2229017002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	09/08/2018 12:00:00 AM	ADDRESS	34.19102	-118.51666	PV1.  Install a 3.9 kW roof mounted grid tied PV system.  (13) modules with 3.8 kW roof mounted grid tied PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6279	13041-20000-35757	8220 N WOODMAN AVE	91402	6	192B157   780	2213021019	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.22035	-118.43224	New service to an existing hospital and connection to emergency generator on application #13041-20000-35751 (E13VN02686)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6280	12041-10002-18703	3041 W 7TH ST	90005		132B197   169	5077011018	C2-2		Wilshire	Wilshire Center - Koreatown			Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.05992	-118.29006	Revision to the approved plan. Addition of 12 door holders. EPC is for the change. (((((((((((((((Install new addressable fire alarm system in an existing mixed use, commercial/college.))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6281	14041-20001-18996	9329 GLORY AVE	91042	7	198B201   359	2572044008	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	PIN	34.23840573	-118.27953851	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 7.6kW.(1) SolarEdge SE7600A-US transformerless inverters(34) SolarEdge P300 power optimizers(34) Solar World SunModule SW250 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6282	13041-20000-23530	1305 N CASIANO ROAD PV1	90049	5	141B141    23	4368027016	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.08607	-118.47188	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 10KW. 31 MODULES AND 2 INVERTERS.  PLAN CHECK/PERMIT IS FOR THE PV SYSTEM ONLY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6283	18041-20001-00613	3617 N HOLBORO DR	90027	4	154-5A203 234	5592007050	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	06/28/2018 12:00:00 AM	ADDRESS	34.11696	-118.27676	06-28-2018 Changes to an approved set of plan. Changes include new 200A panel and relocate Equipment in group of equipment.  Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6284	17041-10003-42324	11904 W TENNESSEE PL	90064	11	123B149   896	4259033002	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.03044	-118.44985	Supplemental for new powerwall battery unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6285	16041-10000-33355	1283 S 3RD AVE	90019	10	129B189   935	5081014011	RD1.5-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.04759	-118.32011	PC for energy only to a New 2-story 6 unit apartment. Installing new lighting in common area garage. New service rated at 400 amps. Total sqft =2795.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6286	14041-10001-22768	123 W 9TH ST	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM			Not Ready to Issue	01/23/2015 12:00:00 AM	PIN	34.04230399	-118.25556747	(1/23/15) Permit pulled on master applicationChanges to approved set.  Changes to lighting and switch from area category method to tailored method.***** Previous work description *****Title 24 plan check only.  Total area = 1,847 sq. ft.  TI to existing retail space.  Removal of one wall and installation of new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6287	14041-10000-35121	12029 W VOSE ST #17	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.19855	-118.39539	Plan check for Title 24 only. Project scope is to replace existing HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6288	10041-10000-20916	142 W SANTA CRUZ ST 1-49	90731	15	018B201   573	7449014020	R4-1XL	Harbor	San Pedro	Central San Pedro	YES	2962.10	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	33.74429	-118.28107	New fire alarm system. Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6289	16041-20000-18267	14505 W FORTUNA LANE	91402	6	198B149   635	2644030215	(T)(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Expired	07/26/2018 12:00:00 AM	ADDRESS	34.24234	-118.44837	Plan check for PV roof mounted system. System size: 5.1 kW. This is an addition of  PV modules plus microinverter to an existing system. Additional of 8 modules and 8 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6290	13041-20000-35038	10158 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.25464	-118.57964	PC FOR T24 ENERGY ONLY. RESTAURANT. LOW ADDITIONAL LOAD. T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6291	19041-10000-04088	1229 S KINGSLEY DR	90006	10	129B193  1137	5080027007	R3-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Apartment			02/04/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	34.04817	-118.30334	NEW FIRE ALARM SYSTEM FOR NEW APARTMENT BUILDING 37 FA DEVICES, AND 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6292	11041-10000-27322	630 S ST LOUIS ST	90023	14	126A221   122	5183023003	[Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Apartment			12/22/2011 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	34.03789	-118.21796	Plan check converting existing dormintory building to a 23-unit low rise apartment building. New 1200A service. Modification seperate fire alarm system from plan has been filed. Per building permit methane site design exempt.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6293	16041-20000-32461	247 N AMALFI DR	90402	11	123B129   701	4410022026	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.03164	-118.51386	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.7KW INTERCONNCTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6294	16041-30000-03130	2080 CENTURY PARK EAST	90067	5	132B161    39	4319001014	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	PIN	34.05920818	-118.41153897	Plan check for power only.  Installation of new 600A medium voltage switchgear to replace five existing oil fused cutouts.  Building is existing medical highrise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6295	16041-10000-04435	3889 N WEST POINT DR	90065	1	145-5A223 238	5451022013	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.09276	-118.21314	PV1 rooftop solar installation 5kWac system. Total system size is 5.0kWac.(17) MODULES-SW280 Mono(1) INVERTER-SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6296	13041-10000-11516	6201 W FOREST LAWN DR	90068	4	168B189   276	5581001906	OS-1XL-H	Central	Hollywood	Greater Griffith Park, Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	05/03/2013 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.15294	-118.32388	TEMPORAAY OVERHEAD POWER TO SERVE TWO 400A PANELBOARDS MOUNTED ON A SERVICE POLE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6297	18041-10002-26793	1310 S ABBOT KINNEY BLVD	90291	11	108B145  1283	4238004015	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	33.99094	-118.46783	"DELTA ""5"" CHANGES TO THE APPROVED PLANS FOR THE ADDITION OF A 45' LINEAR RECESSED LED AND RELOCATION OF RECEPTACLES. . PERMIT WAS ISSUED UNDER: 18041-10000-26793<<<FULL PC FOR POWER AND ENERGY. TI FOR A RETAIL STORE. COMBINE 3 RETAIL STORES INTO ONE. SCOPE INCLUDES RELOCATINGS PANELBOARDS, AND ADDING NEW LOADS. TOTAL AFFECTED AREA IS 4,342 SQFT. BULDING PERMIT# 18016-10000-22884>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6298	14041-20001-17764	13287 N RALSTON AVE	91342	7	225B141   172	2501002027	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.31289	-118.47324	CHAGES TO APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF EQUIPMENT AND NEW SERVICE AND DISTRIBUTION EQUIPMENT. PLAN CHECK FOR CHANGES CLOUDED DELTA 4. NO CHANGE IN ENERGY CALCS UNDER THIS APPLICATION. FAULT CURRENT BASED ON DWP ESR. IF FAULT CURRENT FROM DWP IS GREATER THAN ESR INSPECTOR TO SEND PLANS BACK FOR FAULT CURRENT RECALC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6299	17041-10000-11314	3020 W RIVERSIDE DR	90039	4	153A207   317	5434024026	CM-1VL-RIO	Central	Hollywood	Silver Lake	YES	1882.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.11155	-118.2669	PC for energy only, outdoor T-24. Removing HID fixtures and replacing them with new LED ones. Area: 33,100. Total of 14 fixtures	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6300	14041-10000-07251	11548 W MAGNOLIA BLVD 1-46	91601	2	171B169   436	2354004035	R4-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.1646	-118.38335	This is a admin building,  modular, seven panels, 1 service ckts and out door lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6301	18041-20000-39895	2807 N NICHOLS CANYON ROAD	90046	4	156B177   709	5570033055	RE11-1	South Valley	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.1207	-118.35909	PV1.  Install roof mounted PV system sized 16.6 kW AC interconnected with MSP.  54 kWh energy storage system.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6302	14041-10000-35595	66 E WINDWARD AVE	90291	11	106-5A143  34	4226009012	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Closed	03/26/2015 12:00:00 AM	ADDRESS	33.98736	-118.47249	T24 ONLY.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 1536 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6303	10041-10000-03554	10700 W SANTA MONICA BLVD	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Public Safety Only			03/01/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.05167	-118.432	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6304	19041-20000-20813	1888 S CENTURY PARK EAST 1500	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.06104	-118.41402	Plan check for Title 24 only in existing high-rise in public corridor and public restroom. Total area: 1832 sq ft. B#19016-10000-07282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6305	17041-10001-22475			13	148-5A209 473	5439006032	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	PIN	34.09953928	-118.25996627	PC for rooftop PV for 13 new modules and optimizers, 1 central inverter, two load centers and one 1 energy storage battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6306	17041-10000-20685	10250 W SANTA MONICA BLVD # 1505	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	FIRST TENANT IN RETAIL SPACE AT CENTURY CITY MALL -Tory/Burch- SPACE # 1505	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6307	13041-20001-22068	2035 N HIGHLAND AVE PV-2	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.10759	-118.3376	Supplemental.PV-2. Commercial rooftop solar. 30kW AC system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6308	16041-20002-20320	19339 W LONDELIUS ST	91324	12	195B117   109	2783025049	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.22999	-118.55496	(2/2/2017)supplemental permit to adjust fees.  40 new branch circuits.>>>>>>PC for T-24 only. TI to an (E) commecial space: Change of use from Office and Manufacturing to Office and Motion Picture Film Editing. New load < 400A, total area: 9,550 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6309	10041-10000-21317	515 S FIGUEROA ST 19th fl	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	Tenant improvement in the corridors on the 19th flplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6310	11041-10000-04095	720 S LOS ANGELES ST	90014	14	127-5A211 218	5145002002	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Apartment			03/03/2011 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	34.04271	-118.25086	tITLE 24 AND ENERGY CALCS, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6311	18041-20002-08960	14837 W WYANDOTTE ST	91405	6	186B149   708	2218020023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Issued	09/10/2018 12:00:00 AM	ADDRESS	34.20313	-118.4566	09-10-2018 CHANGES TO AN APPROVED SET OF PLANS, CHANGE INCLUDE RELOCATE EQUIPMENT AND UPDATE AS BUILD DRAWING. ALL CHANGES HAS BEEN CLOUDED. PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222 AND ASSEMBLY BILL 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6312	16041-10000-43145	5334 N ALHAMA DR	91364	3	171B105   311	2167024022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Closed	02/07/2024 12:00:00 AM	ADDRESS	34.1663	-118.59282	FULL PC FOR POWER AND ENERGY FOR AN EXISTING COMMERCIAL BUILDING (HORTICULTURE SPACE). SCOPE INCLUDES NEW PANELS, NEW RECEPTACLES, AND NEW LIGHTS. NEW CONNECTED LOAD >400A. TOTAL AFFECTED AREA IS 3855 SQ. FT. NOTE: CODE ENFORCEMENT INVESTIGATION FEE ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6313	15041-10000-02113	12180 W MILLENNIUM EAST	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Issued	01/23/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	Plan check for Title 24 only. Project is the ground floor lobby (EAST). Total lighting area = 1,825 sq. ft. 2008 compliance forms have been used as the building permit was submitted before 7/1/2014. Plan check for power, outdoor lighting, and the rest of the indoor lighting is under application 14041-20000-06259.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6314	18041-10000-29646	531 N CHAPALA DR	90272	11	126B129   791	4411011023	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.03846	-118.52123	New 2-Story Single Family Dwelling with a 600-Amp service and (5) main panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6315	18041-10000-09296	6734 N ALLOTT AVE	91401	2	180B157  1143	2329011025	R1-1, RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.19298	-118.4279	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 25 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER. TOTAL SYSTEM SIZE 6.875KWDC/5.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6316	14041-20000-35046	1058 S OGDEN DR	90019	10	132B177   957	5086018008	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			12/18/2014 12:00:00 AM			PC Info Complete	02/27/2015 12:00:00 AM	ADDRESS	34.05613	-118.36225	PLANCHECK FOR SERVICE UPGRADE ONLY TO AN EXISTING 5 UNIT APARTMENT BUILDING. 400AMPS 120/240 3 WIRE.[[ PANELS AND CIRCUITS NOT PART OF SCOPE TO BE UNDER SEPERATE PERMIT]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6317	18041-10000-38018	7670 N WOODMAN AVE	91402	6	186B157    73	2214025015	M1-1, RSP-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.21006	-118.43069	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6318	11041-20000-27279	5181 N HARTWICK ST	90041	14	163-5A227 245	5691002006	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2011 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.14173	-118.19712	New 7.2 KW DC roof mounted PV system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6319	13041-10000-14517	20929 W VENTURA BLVD UNIT 22	91367	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	PIN	34.16716286	-118.58942399	T.I and change the use of (E)20' x 91' bakery use portion of building at unit #22 into restaurant.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6320	11041-10000-14113	5651 W 96TH ST	90045	11	093B169   132	4125021025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	09/28/2011 12:00:00 AM	ADDRESS	33.94947	-118.38017	ADDING/RELOCATING OUTDOOR LIGHTING AND ALSO CHANGING A 600A MAINBOARD.  PLAN CHECK FOR POWER AND ENERGY.  CONTACT # (310) 646-4230 EXT. 109 OR 110	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6321	15041-10000-12000	12045 W WATERFRONT DR STE 475	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Expired	05/23/2017 12:00:00 AM	ADDRESS	33.98209	-118.40611	Energy plan check for an office T.I loacted in the 4th floor, Suite 475; scope includes installing new lighting and receptacles in an open office area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6322	14041-20000-17553	1310 W 36TH PL	90007	8	120B197  1091	5040009028	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Closed	01/31/2017 12:00:00 AM	ADDRESS	34.02177	-118.29797	Partial T.I. to an existing Budhish Temple.  Install new 400A service, panels, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6323	12041-20000-02418	16723 W INDEX ST	91344	12	210B137    65	2682009011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.27567	-118.49638	Photovoltaic system using enphase m215 inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6324	17041-10000-10031	1421 S ABBOT KINNEY BLVD	90291	11	108B145  1341	4241036005	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	33.99062	-118.46523	PC FOR ENERGY. INTERIOR TENANT IMPROVEMENT OF EXISTING RETAIL, TOTAL AREA 950 SQ FT.B# 17016-10000-07394	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6325	15041-10000-22341	8809 N O'MELVENY AVE	91352	6	195B165   520	2634035017	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.22943	-118.39699	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6326	14041-20000-17442	2681 W CUNARD ST	90065	14	157-5A219  50	5473017005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.12749	-118.22521	6KW standard PV1 roof-mounted system with (24) Enphase M215 microinverters and Sunmodule SW250 modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6327	15041-20000-43104	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.05007	-118.2433	TI to existing mixed use commercial building (apartment, retail, and parking). Plan check for energy only. Adding new lighting including emergency. Total sqft. 231.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6328	17041-20000-28326	921 N HIGHLAND AVE	90038	4	144B185  1094	5532012042	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.08774	-118.33877	PLANCHECK FOR T24 ENERGY. CHANGE PORTION OF GYM TO OFFICES. 547 SQFT.building permit # 17016-10000-15869	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6329	16041-10000-32804	11840 W FOOTHILL BLVD	91331	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.27349	-118.39431	Full PC for a remodel and addition (shell only) to an exiting retail shopping center. New 2000A Service 120/208V 3phase 4wire. Installing new lighting and power. Totaal sqft = 32375.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6330	18041-10000-45135	9800 S LAUREL ST	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	33.94799	-118.23082	"FIRST TIME TENANT. NEW ""ROSS"" RETAIL STORE. PLAN CHECK FOR POWER & ENERGY. 25,000 SQR FT. BUILDING PERMIT: 18016-10000-37445"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6331	11041-10000-15977	13901 W VENTURA BLVD	91423	4	165B153   479	2271015015	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.14894	-118.43571	T.I.  Existing 7-11.  Renovating the light fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6332	15041-20000-22353	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 plan check only.  Total area = 922 sq. ft.  Renovation of existing office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6333	18041-10000-18959	4801 S CRENSHAW BLVD	90043	8	111B185   363	5013016019	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.99979	-118.33111	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 18125 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6334	13041-20000-23761	7713 N LOMA VERDE AVE	91304	3	189B109  1072	2109021009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.21038	-118.58976	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW USING 22 MODULES TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6335	19041-20000-33860	6641 W SUNSET BLVD	90028	13	147A185   540	5547019035	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.09814	-118.33442	Plan check for Egress Emergency lighting for place of assembly.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6336	16041-10000-34771	728 N SWEETZER AVE	90048	5	141B173   239	5528003203	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			10/07/2016 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	12/14/2021 12:00:00 AM				PC FOR POWER AND ENERGY. New 4 story apartment building with 49 units over 2 story subterranean parking. 3000 A service.  Total area of lighting56637 sq. B#15010-10000-03347	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6337	19041-20000-04896	16735 W LOS ALIMOS ST	91344	12	207B137   306	2683019004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	ADDRESS	34.2657	-118.49683	Plan check for PV roof mounted system, system size: 4.2KW with 12 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6338	16041-10001-12527	230 N RIDGEWOOD PL	90004	4	138B189   547	5516013006	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.07545	-118.31444	04/13/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE ADDING 6 MODULES FROM ONE STRING AND REMOVING 2 MODULES FROM THE SECOND STRING. ALSO CHANGES ON THE PV ROOF-LAYOUT FOR THE MODULE ARRANGMENT. NOTE: PERMIT PAID UNDER PCIS#16041-10000-12527((((PV1, INSTALL 4.335 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(17) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI -3.6-OUTD-S-US Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6339	17041-20000-01594	5365 N VANALDEN AVE	91356	3	171B121   618	2163011028	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.16865	-118.55032	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.24 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6340	16041-20000-45576	475 N BEL-AIR ROAD	90077	5	141B153    56	4362014019	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM			PC Info Complete	02/24/2017 12:00:00 AM	ADDRESS	34.08476	-118.44163	Plan check for power only. New 2-story sfd  w/att. basement/7-car garage/liv. area and New 2-story accessory liv. quarter. 2,000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6341	16041-20000-16076	3651 S TROUSDALE PKWY #319	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.01922	-118.28617	Plan check Title 24 only in USC T.I. existing office and geology laboratory. Total area: 1,053 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6342	15041-10000-34530	7226 N CANOGA AVE	91303	3	186B105   631	2111029001	(T)(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.2021	-118.59752	Plan ckeck for power only.  T.I. to retail first time tenant.  New lighting, AC unit, and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6343	18041-10000-45490	11101 N SALT LAKE AVE	91326	12	210B121   397	2717002037	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.27129	-118.54447	Fee is $2.02 only per AB 1414NEW ROOFTOP SOLAR SYSTEM CONSIST OF 33 MODULES (PANASONIC N330) , 33 OPTIMIZER (SE P400) AND A CENTRAL INVERTER (SE10000H-US).  SYSTEM SIZE IS 9.9KWdc and 10KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6344	18041-10000-36783	523 W 6TH ST 4TH FLR.	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	TI IN EXISTING MEN AND WOMEN RESTROOMS ON THE 4TH FLOOR.T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-13802	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6345	19041-20000-33574	14208 W CHASE ST	91402	6	192B153   312	2638028014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.22488	-118.44241	Plan check for PV roof mounted system, PV system size: 16.56KW DC, 14.892KW AC with 46 PV Moduels and 2 inverters(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6346	11041-10000-24840	1925 S CENTURY PARK EAST suites 220-& 250	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM	12/16/2011 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.06066	-118.41426	title 24 and emergency lighting, high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6347	19041-10000-50731	926 N CITRUS AVE	90038	4	144B185  1081	5532012030	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Closed	04/19/2023 12:00:00 AM	ADDRESS	34.08787	-118.33954	T-24, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES REPLACEMENT OF OUTDOOR FIXTURES TO LED. TOTAL S. FT. 4550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6348	19041-20000-16297	3420 S FARMDALE AVE	90016	10	120B181   889	5046009029	R3-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Issued	05/02/2019 12:00:00 AM	ADDRESS	34.0249	-118.3459	Plan check for PV roof mounted system and battery back up system, PV system size: 7.6KW AC, 8.99KW DC with 31 PV modules and 1 inverter(7.6KW) and LE Chem battery 9.8KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6349	16041-10001-38517	10910 W KINROSS AVE	90024	5	132B149    98	4363023027	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.06033	-118.44604	06/19/2017Changes to an approved set of plans, note changes under delta 2. Changes include the upgrade of a 200A  to a 400Amp panel and the electrical room layout. No new equipment all future loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6350	17041-30000-07281	11064 N SHOSHONE AVE	91344	12	210B129   387	2712004023	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.27169	-118.51732	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (30) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6351	16041-10000-24441	1500 N EL CENTRO AVE	90028	13	148-5A189 331	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.09917	-118.32359	TI TO 1ST FLOOR AND RAISED FLOOR, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. OFFICE TI, NEW LIGHITNG. PC FOR ENERGY ONLY. T24. TOTAL SQ. FT. 6969.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6352	13041-10000-33504	1234 W 7TH ST	90017	1	130-5A207 158	5143009003	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.05185	-118.26696	pc for power only. (e) 2 story building (13016 10 21682). SERVICE UPGRADE TO 800A. 4 tenants at 200A each. 22KAic	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6353	12041-20000-09541	15911 W ARMINTA ST	91406	6	189B141   146	2206007036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Closed	09/14/2012 12:00:00 AM	ADDRESS	34.21399	-118.47971	Plan check for energy and emergency lighting. Commercial kitchen. 1527 conditioned sqft. Single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6354	18041-20000-19238	6160 N LAUREL CANYON BLVD BLDG A	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	"Plan check for power and energy new 3 buildings core and shell feed from existing transformer. Building A has 600A 480V,  Building B 600A 480V, Building BA  800A 480V. Total area indoor and outdoor: 57,593 sq ft . Separate permit shall be issue for each building. B#16010-10000-04930  BUILDING ""BA"", 16010-10000-04929 BUILDING ""A"" , 16010-10000-04928 BUILDING ""B"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6355	15041-10000-02101	12180 W MILLENNIUM WEST	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Issued	01/23/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	Plan check for Title 24 only. Project is the ground floor lobby. Total lighting area = 1,686 sq. ft. 2008 compliance forms have been used as the building permit was submitted before 7/1/2014. Plan check for power, outdoor lighting, and the rest of the indoor lighting is under application 14041-20000-06257.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6356	18041-20000-23586	4120 1/2 S NAOMI AVE	90011	9	115-5A211 264	5115028004	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.10	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.00858	-118.25363	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6357	13041-20000-35331	13455 W MAXELLA AVE 260	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	33.9867	-118.44159	CHANGE TO LIGHTING IN AN EXISTING LOW-RISE OFFICE BUILDING.  LOAD IS LESS THAN 400 AMPS.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6358	13041-20001-22654	8960 S LILIENTHAL AVE	90045	11	096B169  1058	4123015002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	33.95549	-118.38619	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC. 54 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6359	13041-10000-31253	2528 S FIGUEROA ST	90007	9	121-5A203  26	5124027016	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.02852	-118.27554	PLAN CHECK AND PERMIT FOR TI WORK, T24, PART 6 ENERGY, REMODEL FOR RESTURANT IN AN EXISTING BUILDING.TOTAL SQUARE FOOTAGE:1189 SQ FT. 1 STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6360	19041-10000-47063	384 WORLD WAY SPACE  M54	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			Corrections Issued	03/05/2020 12:00:00 AM	ADDRESS	33.94339	-118.40887	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT - SCOPE INCLUDE CONNECTING TO EXISTING AN 5000A 277/480V SERVICE, TOTAL AFFECTED AREA - 1013SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6361	10041-10001-14469	6740 W HOLLYWOOD BLVD	90028	13	148-5A185 149	5547012016	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			PC Approved	05/31/2011 12:00:00 AM	ADDRESS	34.10139	-118.33752	TI CHANGE OF USE FROM RETAIL TO CLASS ROOM TRAINING . NEW 600 AMP SERVICE, PANELS & CIRCUITS. PLAN CHECK IS FOR POWER AND ENERGY.  FIRE LIFE SAFEY PLANS SUBMITTED UNDER PCIS # 10041-10000-14472  <<<<<<<<<<<<<<<MODIFICATION TO APPROVED SET, LOAD CHANGE AND T-24 PERFORMANCE METHOD CHANGES. >>>>>>>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6362	12041-20000-09233	10919 N ARLETA AVE	91345	7	210B149  1198	2615021001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.26855	-118.45304	5.06 kW PV system for a single family dwelling with upgrade main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6363	14041-20001-02287	17445 W CHASE ST	91325	12	192B129   158	2787022007	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	ADDRESS	34.2237	-118.51409	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6364	15041-20000-23262	10820 N AMIGO AVE	91326	12	207B125   124	2717017026	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.26682	-118.53804	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Central inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6365	15041-20000-34574	1845 S PONTIUS AVE 3RD FLR	90025	5	126B153   198	4323026015	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.04443	-118.44248	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING FOR THE 3RD FLOOR. TOTAL AREA IS 480 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6366	12041-20000-18811	731 N ST ANDREWS PL	90038	13	141B193   444	5535015003	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			08/10/2012 12:00:00 AM	09/06/2012 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.08445	-118.31149	new service and feeders to all apartments	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6367	14041-10000-26983	13344 W INWOOD DR	91423	4	162B157   776	2386027015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.13878	-118.42383	Installation of new solar roof mounted PV system.  Total system size = 7.6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6368	17041-10000-42139	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	33.89279	-118.28725	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6369	12041-10000-15812	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR KITCHEN REMODEL FOR SPACE FC-1. CHICKENOW. EXISTING AUTOMATIC TIME CLOCK. PERMIT FOR FOR LIGHTING AND DEVICES ON EXISTING BRANCH CKT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6370	16041-10000-31444	5127 N ROCKLAND AVE	90041	14	162A221    22	5671016005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.14024	-118.21528	Install 5.879 kw ac roof-mounted solar array on a singlr family house, ac inverters.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6371	19041-10000-36147	3540 S DENISON AVE	90731	15	006B197   707	7467007015	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	33.71166	-118.28871	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 16 AC MODULES (SUNPOWER X-22 320) CONNECTED TO AN EXISTING 200A SERVICE. SYSTEM SIZE IS 5.215KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6372	16041-20000-20231	16350 W PLUMMER ST	91343	12	198B137    90	2676010009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.24278	-118.48902	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.2 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6373	11041-20000-13284	9301 N TAMPA AVE Elec Room-#13	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for new 600A disconnect section and conduit only to supply future tenant space #117 (Sephora). Remove existing (2) 400A and (1) 200A section on existing 2000A switchgear located in Electrical Room #13. 600A subpanel and feeder (tenant) installation by others, subject for plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6374	14041-10000-13345	718 S HILL ST	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.04527	-118.25477	Title 24 for a corridor on the 6th floor of a highrise.  Commercial space.Total area = 500 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6375	15041-10002-01077	12558 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.97812	-118.41195	((((5/10/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO ENERGY CALCULATIONS, OCCUPANCY SENSORS AND LIGHTING SWITCHES.  THE CHANGES APPLY TO ALL THE FOLLOWING APPLICATION NUMBERS AS NOTED BELOW.Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6376	18041-10000-35477	3645 N LOWRY ROAD	90027	4	154-5A203 149	5592010004	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.1178	-118.27765	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 10.6 KVA SYSTEM CONSISTING OF 2 INVERTERS (SE7600A-US & SE3000A-US) AND 43 MODULES (P320 OPTIMIZERS) WITH DERATED MAIN BREAKER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6377	12041-20000-18472	5251 N VINELAND AVE	91601	4	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Issued	10/26/2012 12:00:00 AM	ADDRESS	34.16639	-118.37064	T.I. to existing buiilding.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6378	14041-10000-29044	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.06326	-118.20213	New core and shell for outpatient cancer center.  Service is a 12.47 kV service from (E) USC distribution system to a dual feed primary selector switch and then a 12.47kV-480Y/277V 2250 kVA pad mounted XFMR feeding 3000A service inside the building.  500 kW emergency generator, diesel with active DPF.  Critical and equipment power.Note to plan checker: fire alarm system not included in fees, but included in submittal set.  Applicant to file variance to separate fire alarm plans or include in submittal 2 fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6379	19041-10002-17449	5425 W SANTA MONICA BLVD	90029	13	144B193   701	5536010020	C4-1VL	Central	Hollywood	Hollywood Studio District		1911.20	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM			PC Approved	07/05/2019 12:00:00 AM	ADDRESS	34.09092	-118.30773	Plan check only. Changes to an approved set. Changing the type of fixtures from Metal Halid to LED.  Original Scope: T-24, PC for Energy Only. Scope includes adding Outdoor lights for an outdoor sign. NOTE: Plan Check only. Permit is paid under PCIS#19041-10000-17449	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6380	15041-10000-16569	508 W BERNARD ST	90012	1	136-5A215 154	5414006029	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.06723	-118.23769	Energy plan check for an commercial T.I (Nest Studios) ; Scope includes new lighting and receptales.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6381	17041-20002-41504	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.28583	-118.51165	"SUPPLEMENTAL PERMIT TO ADDRESS TEMPERATURE CORRECTIONS FACTOR. CONDUIT WILL BE RAISED TO 4"" ABOVE THE ROOF TO BOTTOM OF CONDUIT PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.145 KW"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6382	11041-20000-20588	25825 S VERMONT AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM			PC Approved	10/24/2011 12:00:00 AM	ADDRESS	33.78808	-118.29535	T24 ENERGY FOR REPLACING LIGHT FIXTURES IN KAISER PARKING STRUCTURE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6383	18041-20001-03430	12506-12508 W MAGNOLIA BLVD	91607	2	171B165   532	2357006017	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.16472	-118.4056	PLAN CHECK FOR ENERGY ONLY FOR CHANGE OF USE FROM RETAIL TO GYM  - TOTAL AFFECTED AREA = 2602 SQ. FT.  INSPECTIONS FEES HAVE BEEN CALCULATED UNDER ORIGINAL PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6384	19041-10001-29205	11517 N BIANCA AVE	91344	12	213B129   250	2607011020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.2799	-118.51422	EXPEDITED PER CUSTOMER REQUEST.PV1. SYSTEM SIZE OF 12.35 KW DC WITH (38) MODULES (DUO-G5 325) AND OPTIMIZERS (P340) INTERCONNECTED WITH (2) INVERTERS (SE7600H).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6385	16041-10000-14935	8951 W HELMS PL	90034	10	123B169   592	4311032041	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.03412	-118.3884	SCOPE INCLUDES A NEW 100A 120/240V 1 PHASE 3 WIRE SERVICE/PANEL, AND NEW BRANCH CIRCUITS. SUBMITTING PLANS PER APPLICANT REQUEST.NOTE: ELECTRICAL EQUIPMENT IS NEW DUE TO FIRE DAMAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6386	12041-20000-06683	924 S TOWNE AVE	90021	14	124-5A211 213	5132003021	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM			PC Approved	03/23/2012 12:00:00 AM	ADDRESS	34.03485	-118.24898	Retail t.i.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6387	15041-10000-29255	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.24253	-118.57768	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6388	14041-10000-26783	1149 S HILL ST SUITE 700	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.03926	-118.26099	T24 ONLY. TENANT IMPROVEMENT ON SUITE 700 (11,866 SQ FT).B# : 14041-70000-12782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6389	10041-10000-24091	6250 W HOLLYWOOD BLVD Suite D	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			12/03/2010 12:00:00 AM			PC Info Complete	01/14/2011 12:00:00 AM	ADDRESS	34.10133	-118.32547	T-24 lighting plan check only for small bakery.  CHANGE OF USE FROM RETAIL TO SMALL BAKERY.  NO SEATING OR EATING IN PREMISES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6390	15041-10000-43024	17383 W SUNSET BLVD B-260	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	INTERIUOR TENANT IMPROVEMENT TO (E) OFFICE.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6391	18041-20001-23905	1244 W 39TH ST	90037	8	117B197   814	5037007001	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			07/20/2018 12:00:00 AM			Re-Activate Application	07/20/2018 12:00:00 AM	ADDRESS	34.01515	-118.29876	07/20/2018 Changes to an approved set of plans. All changes have been approved by LAFD. Changes were made to remove ADA required devices in ADA-compliant bedrooms. *****Previous Work Description*****Plan check for new fire alarm system for 12 units appartment building. Total fire alarm devices: 83 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6392	13041-20001-32923	7810 W GRANITO DR	90046	4	150B177   485	5551005025	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.10426	-118.36061	((Exepite fees))PV1 LOW FREQUENCY TRANSFORMER. TOTAL SYSTEM SIZE 16.56KW. 48 MODULES ADN 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6393	15041-10000-40902	12166 W VENTURA BLVD	91604	2	162B165   183	2369014008	C2-1VL-RIO, R4-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.14322	-118.39712	T-24, TI to an existing commercial building (T-mobile). Existing service and equipement. Scope of work includes new lighting and receptacles. Pc for energy only. Sq Ft = 1786.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6394	14041-10000-14663	5955 W MELROSE AVE	90038	13	141B185   579	5533034012	C4-1XL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.08358	-118.33031	Title 24 plan check only.  Total area = 336 sq. ft.T.I. to existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6395	10041-10000-16566	1237 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.05208	-118.22621	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6396	16041-20000-17263	2631 W SOUTHWEST DR	90043	8	105B189  1430	4007020017	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	33.9813	-118.3224	Plan check for power service upgrade 600A in existing space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6397	13041-10000-28202	4559 N MATILIJA AVE	91423	4	168B153   604	2271005001	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Issued	10/10/2013 12:00:00 AM	ADDRESS	34.15463	-118.43417	PV1. ROOFMOUNTED SOLAR ARRAY. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 6.5 kW DC. 1 STORY HOUSE. (26) SPARP ND-Q250F7 MODULES(26) ENPHASE M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6398	17041-10000-46528	2025 S AVENUE OF THE STARS	90067	5	132B161   724		C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	34.05715	-118.41482	Plan check for a new fire alarm system for a hotel/condominiums centery plaza development. Scope includes (3740) devices, (65) power supplies, and (1) fire alarm panel.Note. Fee per applicant, plan checker needs to recheck prior to final permit is pulled.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6399	19041-20000-19329	3105 W BELLEVUE AVE	90026	13	139-5A203  19	5401022019	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Apartment			05/22/2019 12:00:00 AM	06/26/2023 12:00:00 AM		Issued	06/26/2023 12:00:00 AM	ADDRESS	34.07822	-118.2784	1200 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6400	14041-20003-23980	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM			PC Approved	05/20/2016 12:00:00 AM	ADDRESS	34.14441	-118.39252	05-20-16 CHANGES OT AN APPROVED SET OF PLANS. CHANGES INCLUDE REMOVE DISCONNECT OF PRIMARY TRANSFORMERS AND ADD LOCKABLE ATTACHMENT FOR TRASFORMER BREAKER AND UPDATE FAULT CALCULATION FOR THE TRANSFORMER. CHANGES APPLY TO DELTA 5 ONLY{{{{{{{{{CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3 ON PLANS. NEW 2KVA TRANSFORMER. NEW 800AMP SERVICE FOR 5 STORY TYPE2A OFFICE AND GARAGE BUILDING.(2 STORIES PARKING, 3 STORIES OFFICES.PLAN CHECK FOR POWER AND ENERGY.PLAN CHECK IN ACCORDANCE TO 2008 ENERGY EFFICIENCY STANDARDS DUE TO BUILDING SUBMITTAL.}}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6401	13041-10000-24739	2506 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.0335	-118.2974	PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(12)modules: {Trina {TSM-250PA05.08}}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6402	10041-10000-06599	800 N ALAMEDA ST	90012	14	132A215    65	5409023054	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	10/04/2010 12:00:00 AM	ADDRESS	34.05494	-118.23752	"APPROXIMATELY 1,500 SF OF FOOD RETAIL INTERIOR TENANT IMPROVEMENT AT THE EXISTING STORE ""S1"" OF LOS ANGELES UNION STATION.  PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6403	18041-10001-22583	333 S HOPE ST 33rd FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Info Complete	10/10/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	DELTA CHANGES TO APPROVED PLANS FOR REMOVING FURNITURE LIGHTS FROM INDIVIDUAL OFFICES ON 33RD FLOOR.PLAN CHECK ONLY. ELECTRICAL PERMIT WAS ISSUED UNDER: 18041-10000-22583<<<<Plan check for Power and Energy on (E) office. TI with new loads > 400A, total area: 22,907 sq.ft. 33rd floor. (B# 18016-10000-18297)>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6404	19041-10000-32842	6813 E HOUGH ST	90042	14	154-5A235 619	5493037018	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.11737	-118.17097	PC for PV-1 system. 13 solar panel with microinverter and a combiner box. system size is 4.81KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6405	11041-10000-10270	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.14947	-118.43885	NEW RALPHS WITH PARKING LOT.  EVERYTHING IS NEW.  REGULAR PLAN CHECK.  NOTE TO PLAN CHECKER:  CLIENT BROUGHT A PRE-CUT CHECK.. ACTUAL FEES ARE MORE THAN THE AMOUNT PAID.  VERIFY FEES DURING PLAN CHECK PROCESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6406	14041-20000-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			06/13/2014 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	04/09/2020 12:00:00 AM	ADDRESS	33.95605	-118.38499	New 4-story 61 unit apartment over 2 levels of subterranean parking.  Plan check for power and energy.*3/24/16: Extension filed. Last date to obtain the permit is on 6/13/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6407	19041-20000-36196	12033 N LONGACRE AVE	91344	12	216B125   408	2601031039	(T)(Q)RE40-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	09/29/2022 12:00:00 AM	ADDRESS	34.2896	-118.53069	PLAN CHECK FOR NEW PV ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 22.68KW DC/19.28KW AC. SCOPE OF WORK CONSISTS (63) PV MODULES WITH OPTIMIZERS, (2) 11.4KW INVERTERS, AND (2) SUB PANELS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6408	18041-10000-18904	14006 W RIVERSIDE DR 39B	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC FOR TENANT IMPROVEMENT FOR (E) RETAIL STORE (OLD NAVY) IN AN INDOOR MALL FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 9977 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6409	18041-20000-07808	20645 W CHESTNUT CIR (#267)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29355	-118.58406	Plan check for a PV1 roof-mounted PV system. System size is 2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6410	14041-10000-13864	4892 E AXTELL ST	90032	14	142-5A233 203	5218014014	RD3-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Expired	07/08/2016 12:00:00 AM	ADDRESS	34.08499	-118.1761	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6411	16041-20000-41564	1091 S HOOVER ST	90006	1	130-5A201 224	5076007032	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.05116	-118.28438	Outdoor lighting retrofit for supermarket.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6412	15041-20000-07450	9704 N LEV AVE	91331	6	201B157   506	2621004001	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.24674	-118.42917	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (18) modules and (18) micro-inverters. Standard plan is NOT being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6413	16041-30000-22714	2049 S CENTURY PARK EAST STE 690	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI TO AN EXISTING COMMERCIAL BUILDING (HIGH RISE) 6TH FLOOR.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 5275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6414	16041-10000-05834	410 N LA CIENEGA BLVD	90048	5	138B173    27	5514001011	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Closed	05/24/2017 12:00:00 AM	ADDRESS	34.07843	-118.37638	T-24, PC FOR ENERGY ONLY. TI FOR A RETAIL STORE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2353 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6415	12041-10000-25428	4433 S ALAMEDA ST D4	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.00295	-118.23924	T24 FOR COMMERICAL. 867 SQ FT CONDITIONED AREA, 207 SQ FT UNCONDITIONED, AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6416	18041-20000-46884	13265 W SEVILLANA WAY	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.3154	-118.42251	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) micro-inverters and (7) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6417	17041-20001-26760	18611 W BRYMER ST	91326	12	213B125   145	2872019031	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.28251	-118.5386	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6418	14041-20000-30931	21806 W SIMION LANE	91304	3	186B105  1026	2110004006	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.20932	-118.60333	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.7KW INTERCONNECTED WITH MSP.(22) SOLARWORLD 270W MODULES(22) ENPHASE 215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6419	11041-10000-09709	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Approved	06/02/2011 12:00:00 AM	ADDRESS	34.09786	-118.29745	TI TO AN EXISTING 6-STORY OFFICE BUILDING.  T-24 ONLY PLAN CHECK OTC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6420	16041-20000-20526	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check power and eneregy 1st time tenant  in 14 story building Netflex occupy 1st-2nd floor and 5th-14th floor. Total area: 237,039 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6421	10041-10000-09470	880 W 1ST ST	90012	9	132A211    23	5151016***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Public Safety Only			05/19/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.05728	-118.25174	REPLACING FIRE ALARM SYSTEM AT THE PROMENADE WEST TOWERS; WORK IS TO BE DONE IN TWO PHASES THAT HAS BEEN APPROVED BY LAFD; THIS PLAN REVIEW IS FOR PHASE I WHICH INCLUDES REPLACING MAIN FA PANEL AND ANNUNCIATOR AND SOME DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6422	16041-20001-25630	100 WORLD WAY T1 #120	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM			PC Approved	11/22/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	11.22.2016 - Plan check for modifications to approved set. Increase area of remote storage room, modify lighting plan and T24 compliance forms. Revise specs for fixtures L-10 and L-11. Changes clouded Delta 1.=====Plan check for Title 24 only in existing space space # 120. Total area: 1,465 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6423	18041-20000-24818	2078 N STRADELLA ROAD	90077	5	150B145   109	4377031007	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.10843	-118.46151	Plan check for power only. Project site is a new single-family dwelling. Work includes a 800-amp service.This is a combo permit under building.this is plan check only.Note: Building permit has been issued under 16010-30000-06432	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6424	18041-10000-24629	8101 W MELROSE AVE	90046	5	141B177   567	5528007014	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.08389	-118.36609	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR A COMMERICAL RETAIL AND CHANGE OF USE PORTION OF BUILDING TO CAFE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5837 SQ. FT.  B#18016-30000-18146	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6425	14041-20001-25145	900 N CAHUENGA BLVD	90038	13	144B185  1190	5533019012	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM			PC Approved	02/13/2015 12:00:00 AM	ADDRESS	34.0873	-118.32862	"2.13.2015 - Plan check for modification to approved set. Add a transformer ""T-S2"" fed from panel ""LAN"", panel ""P4S"" fed from the transformer, and a UPS fed from ""P4S"". New branch circuits serving Sample Room 142 on panel ""P4S"". Clouded changes ONLY (non-clouded branch circuits that were rearranged on the panel schedules were not checked under this plan check).[TI in an existing non highrise commercial building. Plan check for power and energy.]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6426	18041-30000-18059	7223 N TYRONE AVE	91405	2	183B153   105	2217003040	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Apartment			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.20174	-118.44468	New Fire alarm system (152) device, (1) FACP on  New 4-story, 38-unit apartment building with parking garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6427	13041-20000-32809	5900 W WILSHIRE BLVD SUITE 550	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6428	19041-20000-41028	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6429	10041-10000-05703	1630 N NORTH MAIN ST Bldg #7	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.06682	-118.22728	Plan check T-24 Energy (general/emergency) lighting on 1st floor LADWP General Services Headquarters (Bldg 7) is for 400A panel with 6 new spare c/b.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6430	16041-10000-28328	16866 W CHARMEL LANE	90272	11	135B117   125	4420035024	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Expired	09/26/2018 12:00:00 AM	ADDRESS	34.06345	-118.5519	Plan check for PV ground mounted system. System size: 11.8kW with 42 modules  and 42 microinverters on SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6431	13041-20000-30751	6333 W 3RD ST Stall 126	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	12/26/2013 12:00:00 AM	ADDRESS	34.07157	-118.36014	Outdoor Farmers Market. Change to lighting and electrical.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6432	11041-20000-05158	11111 W SANTA MONICA BLVD # 950	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR T.I. IN SUITE 950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6433	17041-20000-17215	13113 W VAN NUYS BLVD	91331	7	210B161   744	2535018018	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.26875	-118.41881	PLANCHECK FOR POWER AND ENERGY.  NEW 2 STORY COMMERCIAL BLDG. methane zone. 1076 sqft indoor common areas + 5182 sqft outdoorbuilding permit # 07010-20000-00829	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6434	13041-10000-08682	300 S GRAND AVE	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	PIN	34.05243427	-118.25124731	T24 plan check for an office TI, 3rd floor highrise.  No emergency lighting.  551 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6435	14041-20000-01962	1816 S SHERBOURNE DR	90035	10	126B169   160	4303023004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.04468	-118.38108	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6436	12041-10002-04083	3460 W 7TH ST 1-168	90005	10	132B193   313	5093025028	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM	04/19/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.05958	-118.3025	"DELTA ""5"" CHANGES TO A 13 STORIES, 168 UNIT RESIDENTIAL BUILDING.  SERVICE UPGRADE => 2@ 2000 AMP,  INSTALL A NEW 200KW EMERGENCY GENERATOR AND A 150 HP FIRE PUMP."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6437	17041-10000-04512	16039 W KINGSBURY ST	91344	12	207B141   454	2668003006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.26385	-118.48198	INSTALLATION OF NEW ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE = 5.2KW USING (SUNNY BOY 5.0) INVERTER, AND 21 MODULES(CANADIAN SOLAR-CS6K-280M)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6438	17041-20000-07173	8038 W WILLOW GLEN ROAD	90046	4	153B173    87	5565022017	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Issued	03/22/2017 12:00:00 AM	ADDRESS	34.11886	-118.37183	Plan check for a PV1 ground-mounted PV system. System size is 10 kWac and consists of (1) inverter and (38) modules.Note: Building application has been generated under 16020-20000-02955	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6439	16041-10000-00129	5970 W OLYMPIC BLVD	90019	4	132B177   716	5086025025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.05763	-118.36173	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 1325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6440	15041-20000-27894	18320 W SHEFFIELD LANE	91326	12	213B125   111	2870017030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.28311	-118.53269	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (26) modules, and (2) combiner boxes. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6441	19041-20000-39298												Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM				VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6442	13041-20001-03693	8631 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM			PC Approved	06/10/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	THIS PLAN CHECK IS FOR CHANGES TO APPROVED SET OF PLANS. THIS PERMIT TO REFLECT EAST TOWER. CHANGE IN WIRE SIZE AND TO INSTALL VFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6443	11041-20000-16429	14500 W ROSCOE BLVD Ste 207-& 300	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.22136	-118.44937	complete plan check TI 2nd and 3rd floorA new application (11041-20000-22450) was generated to separate the power and lighting / fire alarm plans.  Permit is to be taken on 11041-20000-16429 only.  The same contractor must pull the permit for the power, lighting, and fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6444	17041-10000-37935	1141 W 2ND ST	90012	1	133-5A209 224	5152009901	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM			PC Info Complete	03/01/2018 12:00:00 AM	ADDRESS	34.0588	-118.25625	PLAN CHECK FOR POWER FOR UPGRADE OF EXISISTING DISTRIBUTION SYSTEM. SYSTEM CONSIST OF NEW 1200A SERVICE WITH ASSOCIATED EQUIPMENT. ALSO ADDING NEW PANELBOARDS, AND EV CHARGERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6445	19041-20000-32224	6654 E POLLARD ST	90042	14	154-5A235 147	5716027023	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.11808	-118.17369	PV1 PLAN CHECK FOR NEW PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 10.23KW DC/9.42KW AC. SCOPE OF WORK CONSISTS OF (31) PV MODULES WITH MICROINVERTERS, A PANEL, AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6446	19041-10000-20996	7253 N ETHEL AVE	91605	2	186B161   585	2327003049	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.20284	-118.41833	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6447	13041-20000-20477	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	T24 FOR RESTAURANT REMODEL. NOT A FIRST TIME TENANT PER APPLICANT. TOTAL SQRFT 1997	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6448	14041-10003-19481	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.11883	-118.2495	02/27/16CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 4 ON PLANS.CHANGES INCLUDE ADDING 15 FIRE ALARM DEVICES TO THE 2ND FLOOR OF THE MAINTENANCE BUILDING. ALSO  REVISING RISER DIAGRAM, BATTERY CALCULATIONS, AND VOLTAGE DROP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6449	14041-20000-28017	998 S ROBERTSON BLVD SUITE 205	90035	5	132B169   213	4333011024	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.05969	-118.38343	PC FOR TI. OFFICE SPACE. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6450	15041-10001-21826	1808 S CARMONA AVE UNIT #1	90019	10	126B177   903	5064010010	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.04106	-118.36071	EXPEDITED PV ROOF MOUNTED ((PV 2, ROOF MOUNTED SOLAR, 2.6 KW PV ARRAY.(1) INVERTER: PVI-3.0-OUTD-S-US-Z-A(10) MODULES: KU2606XPA  ))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6451	17041-20001-45980	9601 N MASON AVE	91311	12	201B109   284	2748003080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM			PC Info Complete	05/01/2018 12:00:00 AM	ADDRESS	34.24457	-118.57997	Revisions to approved set.  Miscellaneous changes to SLD configuration.  (1) 300A feeder changed to (2) 200A feeders to accommodate equipment purchasing.  (((PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT FOR STORAGE WAREHOUSE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6452	14041-10000-05806	1302 W 177TH ST BLDG D	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	INSTALLATION OF A FIREALARM FOR A  NEW  10-unit apartment building (Building D) with community room, fitness, residential office and laundry room. 3 PANELS AND 104 DEVICES.4 OF 6ELECTRICAL P# 13041-10000-06856.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6453	18041-20001-17251	3456 W OLYMPIC BLVD	90019	10	129B189   255	5081026036	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	10/08/2020 12:00:00 AM		Issued	10/08/2020 12:00:00 AM	ADDRESS	34.05232	-118.31379	12-10-2019 Changes to an approved set of plan, Changes include lighting fixture schedule and installed UPS in the patient care area, update  HVAC equipment and Title 24 calculation. All changes has been clouded as delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6454	13041-10000-29431	19601 W GILMORE ST	91335	3	180B117   773	2132013018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.18763	-118.56013	PV1.  Install 7 kW DC roof-mounted solar array, interconnect with main service panel.  Transformed inverter: Fronius IG 5100 NEG.  16 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6455	19041-30000-03847	731 S BROADWAY	90014	14	127-5A209  68	5144014032	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			Corrections Issued	01/31/2019 12:00:00 AM	ADDRESS	34.04456	-118.25423	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 2,785 sq. ft.Note: Building application has been generated under 19016-30000-02004	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6456	14041-10001-23036	12746 W JEFFERSON BLVD Suite 2140	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			PC Approved	04/13/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	((((4/13/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE NEW 75KW TRANSFORMER AND CHANGES TO THE ENERGY CALCS.  plan check for power and energy for wells fargo. (first time tenant).  Total area = 2,544 sq. ft. WELLS-FARGOT.I. to existing shell bldg. BLDG#14016-10-16944. Changes on plan include update MDP demand kva and VD%	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6457	11041-10001-27202	3501 W JEFFERSON BLVD	90016	10	120B185   804	5051029029	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM				REVISED PERMITTED SET OF PLANS SHOWING THAT ALL EXTERIOR CIRCUITS ARE SUPPLIED FROM PANEL HB  IN NEW BUILDINGPLAN CHECK POWER AND ENERGY. NEW 1000A SERVICE ELECTRICAL SYSTEM TO EXISTING COMMERCIAL BLDG;LOAD IS ON HOUSE PANEL ;OTHER FEEDERS ARE STUBBED OUT; TITLE 24 PLAN CHK IS FOR THE ELECTRICAL ROOM ONLY;TENANT(S) WILL DEVELOPE THE REST OF THE COMMERCIAL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6458	19041-20000-37162	11976 N NUGENT DR	91344	12	216B129   200	2601051021	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.28881	-118.51575	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 10.08 KW DC/9.07KW AC CEC. SCOPE OF WORK CONSISTS OF (32) PV MODULES WITH MICROINVERTERS, (2) 13.5 KWH TESLA POWERWALLS, (2) SUB PANELS, AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6459	18041-10000-26805	7059 N VALJEAN AVE	91406	6	183B137   138	2224012030	[T][Q]MR1-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	ADDRESS	34.19929	-118.48599	TI in an existing nursery. T-24 Energy Only. Bldg Permit 18016-20000-17530	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6460	10041-10000-18256	1228 S BUNDY DR	90025	11	126B145   120	4263003270	[Q]PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Public Safety Only			09/15/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Closed	12/19/2011 12:00:00 AM	ADDRESS	34.04372	-118.46678	installation of a fire warning / central station monitoring of five buildings at a water treatment facility	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6461	15041-20000-05293	7301 N MEDICAL CENTER DR	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Issued	02/24/2015 12:00:00 AM	ADDRESS	34.20262	-118.62963	PLANCHECK FOR POWER. TENANT IMPROVEMENT FOR MEDICAL OFFICE. 2 CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6462	15041-20000-20234	11713 N PEARWOOD AVE	91342	7	213B149    64	2612019012	RS-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.28369	-118.45507	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6463	11041-20000-08341	2555 E OLYMPIC BLVD	90023	14	121-5A219  42	5170011***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.02566	-118.2231	Plan check new installation of a roof mounted 1.12MW photovoltaic system interconnected to two existing 4000A services. Dependable Highway Express commercial building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6464	13041-10000-27910	5475 N MAEMURRAY DR	90041	14	165A227    17	5669008004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.14708	-118.19899	PV1.  Install 9.880 kW DC roof-mounted solar array, interconnect with main service panel.  Enphase microinverters M215.  38 modules: LG Electronics LG260A1C-A3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6465	14041-20001-04058	6913 N RUBIO AVE	91406	6	183B137   344	2225007009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.19605	-118.49588	Expedite Fee ONLY*****Roof mounted PV system with 12.25 KWdc.  Install new 125A PV subpanel.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6466	19041-10000-50457	6550 N VAN NUYS BLVD	91401	6	180B149   515	2237013906	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	05/15/2020 12:00:00 AM		Issued	05/15/2020 12:00:00 AM	ADDRESS	34.18983	-118.44839	PLAN CHECK FOR INSTALLATION OF (7) LVL 2  AND (4) LVL 3 EV CHANRGERS. SCOPE OF WORK INCLUDES NEW 150KVA TRANSFORMER, POWER CABNET AND 600A SWITCHBOARD. PV SYSTEM AND 600A 480/277, 3PH 4W SERVICE IS APPROVED UNDER 18041-10000-46337	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6467	16041-10000-00677	633 W 5TH ST 42nd floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	TI to (E) office build. 42nd floor. Install ne ligh and control recetpacles. PC for energy only, total area: 1,422 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6468	15041-20002-18845	19207 W VICTORY BLVD BLDG 1	91335	3	180B121   522	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			09/18/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	34.18674	-118.55154	[[CHANGES TO APPROVED SET OF PLANS.  CHANGING THE MODEL OF 1 INVERTER TO SB3000TL.]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6469	18041-10000-21588	300 S GRAND AVE 30TH FLR	90071	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.05283	-118.25116	Plan check for T24 only, Interior TI to existing office space 30th floor. Work is approximately 3804 SF.(B# 18016-10000-17169)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6470	13041-10001-19121	6954 N HALBRENT AVE	91405	6	183B145   406	2220021002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM			PC Approved	03/07/2014 12:00:00 AM	ADDRESS	34.1973	-118.46452	CHANGES TO APPROVED SET OF PLANS. ADDITION OF 2 MODULES ONLYPV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING 27 MODULES AND CENTRAL INVERTER. TRANSFORERMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6471	19041-10000-28073	10010 S AVALON BLVD 1-4	90003	8	091-5A207 103	6050036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	33.94495	-118.26451	PLAN CHECK ONLY, PERMIT FEES HAVE BEEN PAID FOR UNDER SEPARATE APPLICATION. ________________________________________Building 2 of 5: Note. 5 applications under 1 plan, main service located in bld # 3Full plan check for power and energy for service upgrade to 600A for 22 residential units split up into muiltple buildings. Scope of work includes a new 600A serivce, new resedintial panels, and a new 600 A distribution board. Note building has provided 5 different building numbers for each building, 5 applications were genrated  under one planELECTRICAL Buiding 1: 19041-10000-27892Building 2: 19041-10000-28073*Building 3: 19041-10000-28077Building 4: 19041-10000-28079Building 5: 19041-10000-28081Building 1 B#: 17014-40000-00543Building 2 B#:17014-40000-00545*Building 3 B#: 17014-40000-00546Building 4 B#: 17014-40000-00547Building 5 B#: 17014-40000-00548	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6472	16041-10002-30410	737 S BROADWAY	90014	14	127-5A209  77	5144014030	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.04443	-118.25434	Pc for Delta 2 change, change the size of Fire Pump feeder from #600 to #500 and adding a section for Fire Pump.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6473	15041-20000-35211	5716 N SUNNYSLOPE AVE	91401	2	174B157   327	2343014029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Expired	11/20/2017 12:00:00 AM	ADDRESS	34.17446	-118.42674	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC UISNG CENTRAL INVERTER SYSTEM. USING STANDARD PLAN. TOTAL OF 28 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6474	10041-10000-17533	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	09/03/2010 12:00:00 AM		Permit Expired	11/20/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	Replace an existing damaged 3000 Amp Service Equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6475	17041-10000-39830	10537 N SAN FERNANDO ROAD	91331	7	207B161   394	2620029011	M2-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Issued	11/03/2017 12:00:00 AM	ADDRESS	34.26162	-118.41764	Remove Indoor Metal Halide fixure and replac with new LED Fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6476	10041-10000-04950	1030 E 25TH ST	90011	9	118-5A209 122	5131026027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM			PC Approved	04/30/2010 12:00:00 AM	ADDRESS	34.0197	-118.25481	T-24 LIGHTING PLAN CHECK ONLY FOR RESTAURANT, EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6477	15041-20003-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.25734	-118.50614	Changes to approved set of plans.  Delta 5 revisions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6478	15041-10000-26644	710 S BROADWAY	90014	14	127-5A211  72	5144015036	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.04476	-118.25354	new fire alarm panel, one for one replacement. all devices existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6479	13041-10000-08449	735 S FIGUEROA ST Unit 102	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	TENANT IMPROVEMENT PLAN CHECK FOR TITLE 24 PART 6. LOAD < 400 A, NOTE: ALL PERMITS FOR TITLE 24 ENERGY SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6480	18041-20000-17695	11601 W WILSHIRE BLVD STE 410	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	TI to (E) commercial office space in highrise building.  Plan check for energy - 2475 sq ft.(((TI WORK ON +/- 2475 SF OF THE TOTAL FLOOR AREA. NEW NON-LOAD BEARING NON-RATED INTERIOR PARTITIONS, POWER, LIGHTING, AND FINISHES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6481	15041-20001-01709	2310 S SEPULVEDA BLVD	90064	5	126B153  1023	4322021027	M2-1VL	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.03844	-118.4361	THIS APPLICATION IS FOR T24 PLAN CHECK AND PERMIT FOR LIGHTING. NEW CONTRACTOR FOR LIGHTING PERMIT.PER BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6482	17041-20002-29320	23700 W KIVIK ST	91367	3	171B093   365	2047004007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			PC Approved	01/05/2018 12:00:00 AM	ADDRESS	34.16558	-118.64227	Revisions to approved set of plans - correcting AC-CEC rating on title sheet, removing performance meter.$0 plan check fee per State Senate Bill SB 1222.(((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.1 KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6483	11041-10001-00052	750-754 S BROADWAY	90014	14	127-5A209 314	5144015***	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.04393	-118.25432	Changes from previously approved plans.  Changes in lighting only.  Plan check for energy only.  Permit issued under a separate application.*****Change of use from  existing general  retail  to restaurant  bar with live entertainment and sale and dispensing of a full-line of alcoholic beverages for on site consumption with  a 5980 S.F. restaurant with live entertainment  per ZA-2009-94-CUB, no dancing.  T24 and emergency lighting and minor power. *****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6484	11041-10000-23335	500 S VIRGIL AVE #305	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	03/09/2012 12:00:00 AM		Refund in Progress	04/30/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Change of use from office building to dental office in Suite #305.  Existing Service & Panel,  New Circuits. Plan Check for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6485	12041-10000-07170	10166 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.25503	-118.57961	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT SUITE 10166 MASON AVE. COMBINE 10166 AND 10168 SUITE TO ONE RESTAURANT WITH TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6486	14041-20000-02087	3601 N DELLVALE PL	91436	5	162B137   645	2293003002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Expired	04/05/2016 12:00:00 AM	ADDRESS	34.13642	-118.49531	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 8.8KWAC. USING SOLAREDGE OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6487	13041-20000-22282	9072 W SHOREHAM DR PV-1	90069	4	144B169   527	5560034008	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.09125	-118.3906	PV-1. Microinverter. 3.225kW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6488	17041-30000-43083	1690 N SUMMITRIDGE DR	90210	5	147B157    48	4355009014	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.10148	-118.41962	Plan check for New 6-story single family residence w/ attached garage 1200A, 120/208V 3ph, 4W Service. This is plan check only, Electrical permit is covered in Building Combo Permit.Building permit number 16010-30000-03113	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6489	18041-10000-07063	1850 N CHEROKEE AVE BLDG 2	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.10481	-118.33464	"PC for power and energy for change of use from apartment to hotel. Scope includes new panel ""3F"", lights, receptacles and equipment. This building is 2 of 2 for project and consists of three units and is served by main service located in building 1 (18041-10000-07066). Building 2 # 18041-10000-05773. Building 1 # 18041-10000-05775."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6490	15041-10000-28935	11831 N CHADRON AVE	91331	7	216B161   628	2527002015	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.28496	-118.41578	PV1 for a single family home. Scope of work: (16) modules, (1) inverter of 5kw rating.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6491	14041-20002-35414	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	34.02174	-118.39786	01-28-16 Change to approved set of plans. Changes  include lighting fixtures changed part of dinning area. Changes apply to delta 2 only. {{{{{{Plan check for power and energy. CHANGE OF USE FROM RETAIL TO RESTAURANT OF AN EXISTING 2,218 S.F. SPACE AND ADD NEW EQUIPMENT MEZZANINE FOR STORAGE PER ZA 2011-2464 (ZV). Total area w/Add. is 2,516sqft. New lighting (incl. emergency). Installing >400A of new load.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6492	16041-10001-26764	6643 N BOBBYBOYAR AVE	91307	12	180B093   321	2036003007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.191	-118.63271	SUPPLEMENTAL TO 16041-10000-26764. DERATE MAIN BREAKER TO 175 AMP FOR SOLAR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6493	16041-20000-00128	5419 N TAMPA AVE	91356	3	174B117   599	2163014020	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM			Reviewed by Supervisor	01/15/2016 12:00:00 AM	ADDRESS	34.16954	-118.5536	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 11.772 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6494	19041-20000-10461	15053 W RAYNETA DR	91403	4	165A147   325	2277009018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.14467	-118.46235	INSTALLATION OF A NEW ROOFTOP PV SYSTEM TO EXISTING SFD. SYSTEM SIZE IS 6.1KW DC/5KW AC. SCOPE OF WORK INCLUDES (20) MISSION SOLAR PV MODULES WITH P320 OPTIMIZERS, AND A SE5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6495	14041-10000-04621	3000 S HOOVER ST	90007	9	121-5A201 144	5123005031	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Public Safety Only			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.02712	-118.28376	New fire alarm system for 2 story Bldg. (USC fire station #15)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6496	12041-10000-27133	6507 N LONGRIDGE AVE	91401	2	180B157   710	2326024022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.18862	-118.4216	ROOF MOUNTED PV1 SOLAR INSTALLATION 4.578 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6497	17041-10000-28813	3321 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			09/25/2017 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Closed	01/05/2023 12:00:00 AM	ADDRESS	34.0275	-118.3723	PC for temporary power for 28 story construction site. PC for new 480/277V 1200A distribution board, fire pumps, manlifts, hoists and spider box panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6498	11041-20000-16497	3387 S MOTOR AVE	90034	5	120B161   247	4314022026	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01, 2699.02	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.02775	-118.40985	RESTAURANT REMODEL; energy , emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6499	15041-20001-18153	16331 W TUDOR DR	91436	5	162B137   384	2286004051	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.1391	-118.48777	Expedite per applicant request[[[Plan check for PV roof mounted system. System size: 7.6kW with 28 modules and 2 inverters(3.8kW) trasformerless.]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6500	16041-10008-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS. UPDATED CIRCUIT DESIGNATION AND MINOR LIGHTING CHANGES. CHANGES NOTED DELTA DCN-057. PC ONLY. PERMIT COVERED UNDER MASTER.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6501	18041-20000-42775	3827 S FRANCES AVE 1-18	90066	11	111B153   527	4235002015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Apartment			11/07/2018 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.00135	-118.43648	Plan check for power and energy. Project site is a 5-story, 18-unit apartment building. Work includes a total lighting area of 18,300 sq. ft. and a service size of 1,200-amps.Note: Building application has been generated under 18010-20000-05418	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6502	16041-10000-28951	1575 N GOWER ST 4TH-FLOOR	90028	13	148-5A189 330	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	FULL PLAN CHECK,  INTERIOR TENANT IMPROVEMENT ON (E) OFFICE BUILDING LEVEL 4TH.  INSTALL (3) 200A PANELS. TOTAL AFFECTED AREA 18,149 SQ.FT.((B# 16016-10000-03330)) NOTE. MULTIPLE FLOORS WERE REQUESTED PLAN CHECKED SEPARATELY BY CUSTOMER UNDER ELECTRICAL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6503	16041-20000-36525	1118 N ALEXANDRIA AVE	90029	13	144B197   644	5540009005	RD2-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	PIN	34.09140772	-118.29808904	PV1- Install  (4.085kW) roof mounted system. (Microinverter standard plan). Installing 19 modules total.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6504	18041-20000-29783	20813 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.29523	-118.58716	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6505	13041-20000-25775	4221 W WILSHIRE BLVD SUITE 280	90010	4	132B189    20	5504001014	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.06194	-118.32113	pc for t24 energy only. offices. renovatiobn of lighting. work done in suite 280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6506	15041-10000-02729	8806-8810 S SEPULVEDA BLVD	90045	11	096B165   971	4123001002	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	33.95688	-118.39597	Power plan check for electrical service upgrade to existing commercial building.  New 800 A switchboard with 3 new subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6507	13041-10000-03399	640 S HILL ST Suite 752	90014	14	129A211   207	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM			PC Info Complete	02/14/2013 12:00:00 AM	ADDRESS	34.04631	-118.25384	TI IN AN EXISTING COMMERCIAL AREA IN SUITE # 752. PLAN CHECK FOR T-24 ENERGY CALCS. PERMIT ISSUED UNDER APPLICATION NUMBER 13041-10000-03436.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6508	19041-20000-16154	1835 N ROTARY DR	90026	13	145-5A205 256	5431031027	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Issued	05/03/2019 12:00:00 AM	ADDRESS	34.09253	-118.26855	PV1.  Install 7.56 kW DC / 6.948 kW AC-CEC roof mounted grid tied PV system and 9.8 kWh energy storage system.  (21) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6509	19041-20000-37242	6100 W CENTER DR 9th floor	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	33.97733	-118.3922	PLAN CHECK FOR RESTROOM REMODEL ON THE 9TH FLOOR OF A COMMERCIAL HIGH RISE. LIGHTS ONLY. T24, TOTAL SQUARE FOOTAGE = 475 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6510	19041-10000-05461	11649 W MAYFIELD AVE 1-10	90049	11	129B145   127	4265005006	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.05246	-118.46291	PLAN CHECK FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6511	13041-10001-17091	2970-2980 N RIPPLE PL 1-56	90039	13	151-5A211 312	5442031043	(T)(Q)CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			05/15/2014 12:00:00 AM			PC Info Complete	05/15/2014 12:00:00 AM	ADDRESS	34.10734	-118.24886	modification for approved set , Delta A only, providing feeder in existing cionduit and installing EV receptacles.Permit is under master permit.>>>>>>>New 56-unit condominium.  3-story building and 1 level of subterranean parking.  Power and energy plan check.  Variance required for separation of fire alarm from plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6512	17041-10000-41043	849 N ALAMEDA ST	90012	14	132A215    43	5408011908	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.05756	-118.23746	EXISTING COMMERCIAL SPACE CHANGED TO OFFICES, REST ROOMS, CORRIDOR,ANDJANITOR ROOM.PLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6513	17041-20000-04938	540 S BROADWAY	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.04705	-118.25141	Replacement of facade lighting for commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6514	19041-10000-36672	2011 E ZONAL AVE SUITE #710	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.06159	-118.20463	TI OF EXISTING OFFICE ON THE 7TH FLOOR, SUITE#710. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 19016-10000-26414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6515	18041-10000-24131	20450 W PLUMMER ST	91311	12	198B109    59	2748022047	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.24251	-118.579	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6516	17041-20001-30960	24008 W SCHOENBORN ST	91304	12	192B089   147	2017037015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.22101	-118.64926	Expedited plan check feePV1.  Install 8.54 kW roof mounted grid tied PV system.  (28) modules with 7.6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6517	18041-20002-34477	3720 N LITCHFIELD LANE	91356	3	162B117   401	2177043011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM			PC Approved	10/26/2018 12:00:00 AM	ADDRESS	34.13655	-118.55193	Revision to approved set of plans. 400A distribution panel location added to site plan. Note: $0.00 permit fee due to CA Senate Bill 1222(((PV1.  Install 21.45 kW roof mounted grid tied PV system.  (66) modules with (2) 10 kW rated string inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6518	14041-20000-16871	2254 N MICHELTORENA ST	90039	4	148-5A205 259	5432023015	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.10099	-118.26877	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.88KW INTERCONNECTED WITH MSP.(26) YINGLI ENERGY SOLAR MODULES YL2510P(26) M215 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6519	18041-20000-40247	4417 N SIMPSON AVE	91607	2	165B169   225	2364010022	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.15097	-118.38901	PV1.  Install 13.86kW roof mounted grid tied PV system.  (42) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6520	11041-10000-17301	7040 W SUNSET BLVD	90028	4	147B181   699	5548017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.0978	-118.34321	T.I.  Existing 7-Eleven.  Replacing the existing fixtures with LED fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6521	16041-10000-10608	7625 N MINSTREL AVE	91304	12	186B097   184	2014017007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Expired	04/26/2018 12:00:00 AM	ADDRESS	34.20892	-118.6244	PV1 INSTALL 10KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE AND DERATING OF MAIN BREAKER TO SATISFY THE PV FEEDBACK CONNECTION.(1) INVETER: SOLAREDGE SE10000A-US 240V(42) MODULES:CANADIAN SOLAR CS6P-255P	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6522	19041-10001-03636	621 W ROSECRANS AVE	90248	15	075B201    35	6132006031	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	33.90205	-118.28562	VOID (CANCELED EXPEDITE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6523	17041-30000-21943	633 W 5TH ST 49th Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project site is the common corridors on the 49th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 2,110 sq. ft.Note: Building application has been generated under 17016-10000-17461	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6524	12041-10000-25880	11150 W SANTA MONICA BLVD #1400	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM			PC Approved	10/29/2012 12:00:00 AM	ADDRESS	34.04704	-118.44563	Plan check T24 Energy/Emergency lighting Tenant Improvement on 14th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6525	13041-20000-35698	12500 W FOOTHILL BLVD	91331	7	216B161   489	2527022032	[Q]M1-1, [T][Q]P-1	North Valley	Arleta - Pacoima	Pacoima		1042.04	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	PIN	34.28571006	-118.40855723	Remodel to existing offices in a warehouse.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6526	13041-10000-17403	13025 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	ADDRESS	34.18799	-118.41664	permit to be pulled at EPC counter only. PC FOR ENERGY. TI TO EXISTING SPACE. NAIL SALON. CHANGE OF USE FROM (E) RETAIL TO (N) NAIL SALON (2,300 SQ FT); NO CHANGE OF STOREFRONT, NO CHANGE OF PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6527	15041-10001-41089	3406 W ADAMS BLVD	90018	10	123B189   720	5052015006	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	34.03242	-118.32183	03/08/16Changes to an approved set of plans. All changes are made under delta 2. Changes include decreasing wire size for notification circuit from #12 to #14 AWG. Also making adjustment to voltage drop calculations and battery calculations. Note: Permit pulled under PCIS#15041-10000-41089NEW FIRE ALARM SYSTEM FOR RETIREMENT HOME. 1 FIRE ALARM PANEL AND 88 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6528	13041-10000-36274	1145 S TOWNE AVE STE #9	90021	14	123A211    25	5132010047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.03301	-118.2507	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 560 SQ FT. REPLACING TOTAL OF 3 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6529	14041-20000-12217	23133 W OSTRONIC DR	91367	3	171B093   404	2042014014	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	07/19/2014 12:00:00 AM	ADDRESS	34.16483	-118.63107	PV1Install roof mounted solar array on SFD and on attached garage. System size: 11.2kW(1) SolarEdge SE-10000A-US-240V transformerless inverter(40) SunModule Plus SW-270 mono pv modules(40) power optimizers 300W each	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6530	17041-10001-18139	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM			PC Approved	07/10/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC FOR REVISIONS TO APPROVED SET UNDER B. SCOPE INCLUDES CHANGES TO COVE LIGHTS TYPE. TITLE 24 FORM UPDATED TO REFLECTED NEW LUMINAIRE.PLAN CHECK ONLY!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6531	19041-10000-14141	6326 W LINDENHURST AVE	90048	5	135B177   331	5510020029	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.06612	-118.36579	[e-plan] REVISION TO EXISTING PERMITSPV - 18041-90000-29872BATTERY - 19041-10000-00436DELTA 1 - PER LADWP ESR -- DC DISCONNECT FOR BATTERYADDED AND PROTECTION FOR THE EQUIPMENT TO BEINSTALLED. SINGLE LINE UPDATED TO SHOW FEEDS FROMUTILITY AND STOREDGE INVERTER TO CRITICAL LOADCENTER WITH MECHANICAL INTERLOCK DEVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6532	10041-20000-16885	970 W 190TH ST SUITE 995	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM	08/26/2010 12:00:00 AM		Permit Finaled	09/15/2010 12:00:00 AM	ADDRESS	33.85812	-118.29302	lighting in office area. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6533	17041-20000-14007	15532 W DEARBORN ST	91343	7	198B145   420	2656027080	R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Issued	04/27/2017 12:00:00 AM	ADDRESS	34.23696	-118.47113	pv1install roof  mounted pv system sized 6.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6534	18041-10000-38196	2410 N HYPERION AVE	90027	4	148-5A205  62	5432003025	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.10298	-118.27293	PC FOR ENERGY TO AN OFFICE TI. SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS, NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 6697	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6535	14041-20000-01408	1940 S WESTGATE AVE	90025	11	123B149   266	4262024014	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Issued	01/16/2014 12:00:00 AM	ADDRESS	34.03569	-118.45325	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KWA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6536	18041-10000-26169	20409 W PRAIRIE ST	91311	12	198B109    91	2748022085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.23923	-118.57783	REPLACE INDOOR/OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6537	13041-20000-27145	804 N EL CENTRO AVE	90038	13	141B189   100	5534031017	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Issued	04/04/2014 12:00:00 AM	ADDRESS	34.08554	-118.32428	PC FOR POWER AND ENERGY FOR TI OF EXISTING THEATER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6538	13041-10000-34857	5857 S CENTRAL AVE SUITE 120	90001	9	108B209  1588	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	"T24 PART 6 ENERGY FOR ""YOGURT LAND"" IN SINGLE STORY BUILDING, IN STE #120. SCOPE OF WORK < 400A. PROJECTED AREA IN SCOPE OF LIGHTING WORK IS APPROX. 1231 SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6539	11041-20000-01877	330 S LA CIENEGA BLVD	90048	5	138B173   831	5511032047	C2-1VL-O, P-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	07/19/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.07282	-118.37627	PLAN CHECK POWER AND ENERGY FOR NEW PETSMART IN EXISTING BUILDING. NEW ELECTRICAL SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6540	16041-10000-03670	2049 S CENTURY PARK EAST ROL-13-Level D	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI-24, PC for energy only. Change of use from office to barber shop in suite # ROL-13 on Level D (level below ground level). total affected area is 745 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6541	14041-20000-17829	22700 W COVELLO ST	91307	12	186B097   362	2022010005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Expired	08/09/2016 12:00:00 AM	ADDRESS	34.20724	-118.62134	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.6KW INTERCONNECTED WITH MSP.(2) AURORA UNO TRANSFORMERLESS INVERTERS (28) TRINA SOLAR MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6542	18041-10000-32763	10438 N ORO VISTA AVE	91040	7	204B189    96	2560007022	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Issued	08/28/2018 12:00:00 AM	ADDRESS	34.25899	-118.31562	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6543	12041-10000-23234	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	10/25/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	Change of use from retail space to retail bakery (no seatings).  Install indoor and outdoor general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6544	18041-10000-11977	7600 N BALBOA BLVD 108	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT. FIRST TIME TENANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1453 SQ. FT.  B#18016-10000-09615	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6545	18041-20000-10345	5808 W SUNSET BLVD 8th Floor	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Issued	03/22/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	TI to (E) commercial office space - 500 sq ft.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6546	16041-10000-41372	3737 W BEVERLY BLVD	90004	13	138B197   306	5501001019	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.07647	-118.29004	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING TO MORE ENERGY EFFICIENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6547	18041-10000-18251	20065 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Closed	03/16/2021 12:00:00 AM	ADDRESS	34.27548	-118.57184	PC FOR NEW FIRE ALARM IN A NEW COMM. BUILDING. SCOPE INCLUDES SINGLE FACP AND 43 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6548	16041-10000-10823	4012 S HUBERT AVE	90008	10	114B185   187	5033021002	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.01135	-118.32889	PV1, rooftop solar installation 3.0 kW AC.     (15) MODULES-KD255GX-LFB3      (1) INVERTER-PVI-3.0-OUTD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6549	19041-10000-04887	1208 S ABBOT KINNEY BLVD	90291	11	108B145  1220	4238003043	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Issued	02/11/2019 12:00:00 AM	ADDRESS	33.99125	-118.46882	PC FOR FA, 1 PANEL AND 9 DEVICES FOR INTERIOR & EXTERIOR T.I. OF (E) RETAIL W/STRUCTURAL REVISIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6550	17041-10001-24700	1395 N VINE ST BLG D	90028	13	147A187   348	5546016022	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM				Change to approved set by updating the two breakers for the tower cranes.(((PC FOR TEMP POWER FOR A  MULTIPLE BUILIDINGS SITE FOR CORE AND SHELL CONSTRUCTION. SCOPE INCLUDES 2 TEMP-SERVICES OF 1600A 480/277FOR SPIDER BOXES, TEMP CONSTRUCTIONS CONTAINERS, CRANES, MANLIFTS AND POWER SKIDS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6551	18041-10000-32386	6240 W SUNSET BLVD	90028	13	147A189   224	5546025006	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Apartment			08/24/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/26/2021 12:00:00 AM	ADDRESS	34.09778	-118.32504	PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. SCOPE INCLUDES 592 FA DEVICES AND 12 POWER BOOSTERS AN A FIRE CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6552	18041-10000-20930	4810 W WASHINGTON BLVD	90016	10	126B181  1168	5062001001	[Q]C2-1VL-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2186.00	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.03961	-118.34379	PC FOR A RETAIL TI  TO replace (e) damage exterior walls and install (n) store front of (e) URM commercial building; SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1800 SQ.FT B#16016-10000-29983	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6553	18041-10000-28569	10140 N WOODWARD AVE	91040	7	204B193  1145	2559024009	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.25353	-118.30693	Install Rooftop solar system on a (E) SFD,  New system added is 3.8kW AC/ 5.040 kW DC. (1) central inverter, (14) modules with power optimizers. New system is being combined to existing pv system by a new load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6554	12041-10000-25824	9301 N TAMPA AVE #80	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TI REMODEL OF RETAIL SPACE #80	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6555	16041-10001-12885	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Closed	10/15/2020 12:00:00 AM	ADDRESS	34.21922	-118.44896	"Supplemental application for changes to layout of single line including fire pump connection in existing 13 story commercial highrise adaptive resuse project.  Downsize service ""MS1"" and emergency generator.  Increase size of service ""MS2"".  Relocate loads from ""MS1A"" to ""MS2"".  Add new loads to service ""MS1"" including EV chargers.   Changes to retail areas.  Master application has not been approved - SH original plan checker."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6556	18041-10000-19638	4923 N EAGLE ROCK BLVD	90041	14	160-5A221  36	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.13592	-118.21534	PC FOR T-24 ENERGY ONLY . SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 900 SQ-FTB# 18016-10000-16679	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6557	13041-10000-12216	23640 W VICTORY BLVD	91367	3	180B093   854	2035008020	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.18641	-118.64188	TI to an existing fast food restaurant (single story, 1703 sq ft).  Newly connected load < 400 A.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6558	12041-10000-21769	1450 W O'FARRELL ST	90732	15	018B193   280	7446002003	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2012 12:00:00 AM	03/04/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	33.74626	-118.30819	NEW 1.17KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6559	19041-20000-05246	5262 W SUNSET BLVD	90027	13	147A195   115	5544034036	C2-1D	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM			PC Info Complete	02/13/2019 12:00:00 AM	ADDRESS	34.09795	-118.3049	Plan check for Title 24 only in existing space change of use from take out restaurants to bakery. Tenant Improvement. Total area: 1179 sq ft. B#19016-20000-04120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6560	17041-20002-28818	9516 N BADEN AVE	91311	12	201B097   183	2727001031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.24329	-118.61894	Revisions to approved set.  Change on SLD from main panel upgrade to derated main breaker.  $0 plan check fee due to State Senate Bill SB 1222. (((Plan check for solar pv system, roof-mounted on SFD.12.72kW ungrounded system.(53) EnPhase M250 microinverters.(53) 290W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6561	16041-20000-13566	17608 W LEMAY PL	91406	6	180B129   382	2229017002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.19102	-118.51666	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.9 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6562	16041-10000-02050	10552 W PUTNEY ROAD	90064	5	126B161   301	4318010009	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.03988	-118.41913	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.6KWac. (17)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB#PVI-3.6-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6563	16041-10000-11451	1515 W 240TH ST	90710	15	042B193   718	7439008032	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	01/11/2023 12:00:00 AM	ADDRESS	33.8074	-118.30413	PC for title 24 only. Replacing from existing HID lamps to new LED fixtures to a manufacturing wherehouse facility for showcasing. Total area = 36,815. Plan checker to verify manufacturing spec sheets of fixtures. Submitted per customer request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6564	17041-10002-14659	3096 S MCCLINTOCK AVE	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.02647	-118.28575	Change to approved set by modifying the control system on the floor plan. All changes under delta-5 only.(((PC FOR ENERGY. T.I FOR A RETAIL STORE. CONNECTED LOAD < 400AMP. TOTAL AREA 3203 SQ FT. B # 17016-10000-11442)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6565	13041-20004-03721	1901 S BUNDY DR BLDG 1	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.03497	-118.45709	changes to approved set of plans. changes to site lighting. plan check only t24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6566	19041-10000-24321	2206 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.03796	-118.44083	P.C FOR T.I TO EXISTING RESTAURANT. TOTAL AFFECTED AREA 1169 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6567	15041-20000-00172	18654 W PARTHENIA ST	91324	12	195B121   416	2785002025	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			01/05/2015 12:00:00 AM			PC Info Complete	01/20/2015 12:00:00 AM	ADDRESS	34.22809	-118.54008	T.I. to existing building.  Install indoor general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6568	12041-10000-27388	6600 W LEXINGTON AVE	90038	4	144B185   463	5532023001	[Q]CM-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM			PC Approved	11/14/2012 12:00:00 AM	ADDRESS	34.09249	-118.33332	PLAN CHECK FOR ENERGY. OUTDOOR LIGHTING RELOCATIONTERMITE AND DRY ROT REPAIR, REPLACE STUCCO, ADD INSULATION AND REPLACE WINDOWS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6569	14041-20000-30645	9818 N RHEA AVE	91324	12	201B121   203	2763027024	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Closed	01/06/2016 12:00:00 AM	ADDRESS	34.24913	-118.54135	PV1Using standard plan.Install roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 6kW. Ungrounded system.26  255W modules across 3 strings (10 and 8+8=being combined)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6570	14041-10000-10824	8500 W BEVERLY BLVD #761	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	permit to be pulled at EPC counter only. Plan check for energy only. Beverly Center - Salvatore Ferragamo. See bldg#14016 10 07812.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6571	18041-20000-34252	8635 W 3RD ST 465-west	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.07373	-118.38073	ti to an existing commercial medical building, consultation only.  plan check for power and indoor energy only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6572	19041-10000-27097	11305 N QUAIL CREEK ROAD	91326	12	210B117    17	2822017021	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.27608	-118.55647	[e-plan] PV1. 9,045W Solar Electric System(27)LG LG335N1C-V5 MODULES, (27)ENPHASE IQ7-60-2-US MICROINVERTERS WITH UNIRAC SOLARMOUNT LIGHT RAILS, UNIRAC TILE HOOK UNIVERSAL MOUNT MOUNTSSystem size is 6.48KWac and 9.045KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6573	14041-20000-09289	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.06307	-118.2	TI for private office spaces in USC health sciences campus 2-story building (Clinical Sciences Annex).  Title 24 plan check for changes to lighting system for offices 218 and 220.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6574	17041-10000-14385	609 W AVENUE 26	90065	1	142-5A219  36	5453011007	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.08631	-118.22493	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new led ones. Area: 900 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6575	11041-20001-20573	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM			PC Approved	10/24/2011 12:00:00 AM	ADDRESS	33.78734	-118.29768	Modification to an approved set of plans  Modifications are providing detail for post that will be replaced and the use of a different light fixture.  Plan check is for energy only.  <<<<<<<Open parking lot.  Replacing the light post and light fixtures in the open lot.  Plan check is for energy only.>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6576	16041-10000-37024	14345 W ARMINTA ST	91402	6	189B153   973	2212028900	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.21315	-118.44384	PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 81250 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6577	13041-10000-07837	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK FOR LAX FIRST TIME TENANT DUTY FREE SHOP (BURBERRY STORE). 1250 SQRFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6578	12041-20000-12073	1080 S LA CIENEGA BLVD	90035	5	132B173   684	5087001038	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.05713	-118.37597	"T.I. to existing building on the 3rd floor of suite 310 and 311.  Install general/emergency lighting.  Plan check for energy only.COMPLY WITH DEPARTMENT ORDER effective date05/14/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".Note: Permit issued under 12041-20000-12076"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6579	19041-10000-48179	380 WORLD WAY TBiT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2321 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6580	17041-10000-10219	16887 W CALLE DE SARAH	90272	11	138B117    49	4431038004	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.07782	-118.55268	PV INSTALLATION OF A NEW 12.600 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A RESIDENTIAL HOUSE(35)MICRO INVERTER: SPR-X22-360-C-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6581	12041-20000-15749	9911 W PICO BLVD 970	90035	5	129B165    65	4330005043	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM			PC Approved	07/09/2012 12:00:00 AM	ADDRESS	34.05339	-118.40441	T-24 lighting plan check for space 970.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6582	18041-20000-22526	16743 W SCHOENBORN ST	91343	12	192B137   231	2689012013	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.22285	-118.49793	Plan check for Title 24 Energy only in existing space T.I. office space. Total area: 3,436 sq ft. B#18016-10000-13623	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6583	18041-10000-46191	10617 N BATON ROUGE AVE	91326	12	207B117   314	2728004002	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.2631	-118.55441	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 30 MODULES AND 30 MICROINVERTERS  IQ7X-96-2-US). SYSTEM SIZE IS 9.9 KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6584	10041-10000-24253	621 S WESTERN AVE 206 & 207	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TIME TENANT- HAIR SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6585	12041-10000-22067	2939 N DENBY AVE	90039	13	150B213   843	5442022017	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/17/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.10439	-118.24342	PLAN CHECK FOR NEW CENTRAL STATION MONITORING FIRE SPRINKLERED SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6586	12041-10001-25856	21021 W ERWIN ST	91367	3	177B109     7	2149004007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.18304	-118.59175	Modifications to approved set, under delta-5 and 6 changes.  Minor Title 24 fixture changes.  Addition of 2 new panels for pool equipment and one new panel for trash compaction.  Additional power for smoke fire dampers, trash compactors, and mechanical units.  Revision comments submitted along with copy of original approved set.  Originally plan checked by Peter Ungsethaphand.   07-26-2013Original description: Plan check for power and energy. New 7 story parking structure accessory to proposed apartment building. Low rise structure. Includes 6 electrical vehicle charging station and 34 station for future.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
6587	19041-20000-45463	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM			PC Info Complete	12/04/2019 12:00:00 AM	ADDRESS	33.76094	-118.29308	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS CONNECTED LOAD BELOW 400AMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6588	18041-10000-36669	537 S BROADWAY 6TH FLR &-Mezzanine	90013	14	129A211   120	5149033003	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.04731	-118.25166	PLAN CHECK FOR TITLE 24 ONLY FOR NON HIGH RISE BUILDING  - TENANT IMPROVEMENT FOR OFFICE TENANT ON 6TH FLOOR; NO CHANGE IN USE OR PARKING.  No exterior changes. - TOTAL AFFECTED AREA = 3080 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6589	14041-20000-17508	1150 S OLIVE ST 32nd floor	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.03962	-118.26181	plan check for title 24 energy and emergency only.  existing high rise building all circuits are exhisting.  work to be performed will be on the 32nd floor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6590	17041-20000-17400	4600 N ENCINO AVE	91316	5	168B129   718	2290022025	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	PIN	34.15290127	-118.51324665	New single-family dwelling. Work includes an 800-amp service and associated distribution equipment.Note: Building permit has been issued under 13010-30000-04155 and includes electrical permit fees for residential wiring.  Permit issued under this application number for electrical service and meter release.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6591	18041-10000-04385	8500 W BEVERLY BLVD # 663	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT  IN A JEWELRY STORE AT THE BEVERLY CENTER MALLPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6592	14041-10000-32954	14212 W REMINGTON ST	91331	6	198B153   275	2644012024	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.24162	-118.44258	Plan check for PV1 roof mounted. System size: 3.8kW with 1 inverter and 12 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6593	16041-10013-25972	200-300 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	REDUCTION IN SCOPE OF WORK. REDUCE AS NOTED DCN-064. REMOVAL OF CIRCUITS AND LIGHTING, T24 IN MATRIC OFFICE SPACE. PC ONLY - PERMIT STILL COVERED FROM MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6594	10041-10000-12117	1400 N SPRING ST	0	1	136-5A217  83	5409004007	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM			PC Info Complete	06/29/2010 12:00:00 AM	PIN	34.06640655	-118.23243996	ENERGY TITLE 24 AND EMERGENCY LIGHTING. 1 STORY BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6595	14041-10000-21285	888 W 6TH ST 1st floor	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.05062	-118.25846	PLAN CHECK ONLY. Permit fees on 14041-10000-21899 (plan check for power).  plan check for energy (2013 standards). TI TO 1ST FLOOR AND MEZANNINE of 15 story high rise. Emergency lighting installed. 8700 SF for travel agency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6596	12041-10000-22722	7083 W HOLLYWOOD BLVD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM			PC Approved	09/26/2012 12:00:00 AM	ADDRESS	34.10173	-118.34439	Ti for a cafe in the ground floor of an commercial BLDG. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6597	13041-10000-36095	5353 W WILSHIRE BLVD	90036	4	135B181   911	5508008001	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.06241	-118.34536	CHANGE OF USE FOR PORTION OF BUILDING FROM RETAIL TO NAIL SALON.  TENANT IMPROVEMENT FOR NAIL SPA (620 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6598	15041-10000-31637	2014 S VIRGINIA ROAD	90016	10	126B185  1298	5061003016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.03756	-118.33623	PV1, INSTALL NEW 8.215 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(31) MODULES: KYOCERA KU2656ZPA(1) INVERTER: FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6599	14041-20000-05203	12809 W NORTH SEAGLASS CIR	90094	11	102B161  1224	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	33.97502	-118.41801	ROOF-MOUNTEDPV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6600	13041-20000-35478	444 S FLOWER ST 15TH FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	T24 FOR EXISTING HIGHRISE OFFICE 15TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6601	11041-10000-13926	948 N BEAUDRY AVE	90012	1	136-5A213  68	5406026004	R3-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			07/06/2011 12:00:00 AM			Corrections Issued	08/09/2011 12:00:00 AM	ADDRESS	34.06846	-118.24604	8 UNIT APARTMENT BUILDING.  2-STORIES W/SUBTERRANEAN GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6602	13041-10000-36204	11958 W BURTON ST	91605	6	192B165   616	2310003010	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	34.22061	-118.3938	PV1, INSTALL ROOF-MOUNTED SOLAR  , INTERCONNECTING TO (E) 200A MAIN IN A  HOUSE. non-standard plan. SYSTEM SIZE IS 4 kW DC. (16)power  optimizers:Solaredge Op250-LV-MC4SM-2NA-Z   (16)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6603	11041-10002-00229	2101 E PACIFIC COAST HWY	90744	15	033B213    10	7428007003	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	33.79173	-118.23549	replacement setREPLACE AN EXISTING FIRE PUMP SYSTEM IN THE NORTH PLANT OF TESORO REFINARY. (((12-10-12  deleting interlock between main 200 amps BRKRS )))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6604	12041-10000-30861	3703 N BEVERLY RIDGE DR	91423	5	162B149   488	2274016011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.13797	-118.44763	New roof mounted P.V. system with 12 KWdc.  Permit include upgrade main panel to 225 Amperes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6605	13041-10001-18445	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008020	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.05001	-118.25963	REVISIONS TO APPROVED SET OF PLANS;LOADS WERE SHIFTED AROUND TO OTHER SERVICES; ELEVATORS ADDED AND PLANS REVISED TO AS-BUILT CONDITIONS((((((((((TEMPORARY CONSTRUCTION POWER FOR THE CONSTRUCTION OF THE NEW GRAND WILSHIRE HOTEL AND 5-STORIES PODIUM BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6606	17041-20000-30958	15910 W VENTURA BLVD Suite 800	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.15561	-118.47969	Plan check for energy only. TI to existing office suite 800 in high rise building. New lighting (incl. emergency) - 4,985sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6607	18041-10000-09005	965 N VIGNES ST #3/ #4	90012	14	133-5A217 119	5409016033	[Q]M3-1-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM			Corrections Issued	03/12/2018 12:00:00 AM	ADDRESS	34.0585	-118.23235	PC for T24 only for new lighting in service area of restuarant. Total sqft is 241. Installing new lights, receptacles and equipment. B# 18014-10000-00647.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6608	15041-10000-11278	4620 N TILDEN AVE	91423	4	168A151   109	2265013023	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Apartment			04/15/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.15558	-118.44746	INSTALL 16830 W DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(66)MODULES: HANUHA ACELL 260W(2) INVERTER(S): SMA AMERICA SB7000US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6609	19041-20000-05120	6520 N CANOGA AVE D1	91303	3	180B105    73	2148031901	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.1904	-118.59719	New circuits and receptacles for existing retail store.  No change of use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6610	17041-20000-18137	14333 W ROSCOE BLVD	91402	6	192B149   362	2638026001	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Apartment			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.22177	-118.44569	new fire alarm system 162 devices and facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6611	15041-10000-14548	13900 N TUCKER AVE	91342	7	228B161    65	2582026015	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.32465	-118.4078	PV1 GROUND MOUNTED SYSTEM. SYSTEM SIZE 5KW INTERCONNECTED WITH MAIN SERVICE PANEL. (22) SOLAR WORLD SW250 POLY (22) SOLAREDGE POWER OPTIMIZER OPJ300-LV(1) SOLAREDGE INVERTER SE5000 A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6612	19041-20000-17808	20101 W RINALDI ST #110	91326	12	213B113   483	2701100006		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	09/03/2021 12:00:00 AM	ADDRESS	34.27545	-118.57197	T24 PLAN CHECK FOR RESTAURANT TI IN EXISTING LOW RISE COMMERCIAL BUILDING. FIRST TIME TENANT. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1186 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6613	11041-10001-13052	6310 W SAN VICENTE BLVD 290	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			PC Approved	06/27/2011 12:00:00 AM	ADDRESS	34.06084	-118.36757	Per Inspector's request, Title 24 plan check only.  Remodel of light fixtures for Dr. Varkey's office.  <<<<<tenant improvement install lights and power outlets>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6614	11041-20000-21308	530 S LEVERING AVE	90024	5	135B149   274	4366027031	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2011 12:00:00 AM	10/28/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	ADDRESS	34.06715	-118.45555	New 5.16 KW roof mounted PV system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6615	17041-20000-27971	777 S ALAMEDA ST #174	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.03396	-118.24117	Tenant improvement of retail space.  Plan check for energy - 2,527 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6616	17041-10001-12512	12655 W BLUFF CREEK DR	90094	11	102B161  1281	4211037197	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/06/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	33.97565	-118.41332	Changes to approved set. Changes under delta 5. Plan shcek only.Scope includes changes to conductor on firepump feeder to MI cable and relocation of fire pump from inverter room to electrical room. Installtaion of new 30 HP fire pump with remote disconnect section.  One new jockey pump also.  Master permit under application #15041-10000-00589	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6617	18041-30000-27693	816 W BARTLETT ST	90012	1	135A213   320	5407004041	R4-1	Central	Central City North	Los Angeles Historic Cultural	YES	2071.01	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.06279	-118.24496	Install New Fire Alarm system, (1) panel, (92) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6618	15041-10001-14744	10989 W VENTURA BLVD RiteAid	91604	4	162B173   398	2366022022	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.01	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.14107	-118.36985	Changes to an approved set, note changes on delta 2 and delta 1. 2 new ckts and revised plans. (((ALTERATIONS IN THE SALES/RETAIL AREA OF A RITE-AID STORE : NEW PANEL BOARDS;NEW LUMINIRES AND RECEPTACLE CKTSPLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6619	15041-20002-31594	12056 N ADELPHIA AVE	91340	7	216B161   105	2514005038	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.28948	-118.41235	01/15/2016 Changes to an approved set of plans. Changes have been made to reflect field installation. Module count has increased by (1) and inverter size has increased to 5 kWac.*****Previous Work Description*****PV1Install a roof mounted solar array on a SFD. Interconnect with a 100A MSP.Ungrounded system. Using 300W power optimizers (1 per module). (18) 260W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6620	18041-10000-35863	3001 S MAIN ST	90007	9	120A205   277	5122004028	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.02169	-118.27093	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6621	10041-10000-01068	3435 W WILSHIRE BLVD 152	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00, 2123.04	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.06194	-118.29866	T. I work in office area of unit 152. This P/C is only title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6622	16041-20000-43893	23218 W COLLINS ST	91367	3	174B093   283	2041011030	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.17356	-118.63269	permit fee $0.00 by state senate bill no.1222Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 400A MSP.15.2kW (7.6+7.6) ungrounded system. (53) 315W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6623	19041-30000-50120	16461 W VENTURA BLVD	91436	5	168B137   331	2260009044	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.15772	-118.49199	PC FOR ENERGY ONLY, PER INSPECTORS REQUEST, SCOPE OF WORK INCLUDES ADDITION OF FIXTURES. TOTAL AFFECTED AREA IS 16,961 SFQT. NOTE AN EXPRESS PERMIT HAS BEEN PULLED COVERING PARTIAL PERMITS, 19041-20000-38926.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6624	19041-10000-28246	960 W 7TH ST	90017	14	129A207    16	5144009079	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	11/13/2023 12:00:00 AM	PIN	34.04918918	-118.26209882	Full PC for power and energy. Scope includes a new service size  1600A 4160V 3phase 3 wire Service/Switchgear, three 4000A unit substations, new distribution boards, two 250 HP fire pumps and two 350 HP fire pumps,  and new lights. Total affected area is 415,295 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6625	14041-20000-16665	7470 N FIGUEROA ST 2nd floor	90041	14	162A231    31	5709001014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.13993	-118.18696	Plan check for energy only. TI to 2nd story of (E) 3-story commercial office building.  Plan check for energy for changes to lighting system.  2nd floor phase newly connected load under 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6626	18041-10000-05452	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	PC for T24 only. Replacing existing lighting with new LED lights in public areas and restrooms at LAX terminal 4, installing fans and new receptacles in bathrooms. Installed load <400A. Total area is 51874. Project #5.B# 17016-10000-37905TENANT IMPROVEMENT FOR PUBLIC AREAS  INCLUDES RESTROOM RENOVATIONS AT THE ARRIVALS, TICKETING AND CONCOURSE LEVELS, SECURITY ALPHA-1 CHECK POINT CORRIDOR UPGRADE,  AND CONCOURSE CEILINGS AND COLUMN CLADDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6627	17041-10001-06778	515 S FLOWER ST 12TH LOBBY	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 only in existing corridor and elevatior lobby on 12 Floor. Total area: 2504 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6628	16041-10002-38467	20445 W ESMERELDA LANE	91326	12	216B109   263	2701082078	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM			Corrections Issued	09/29/2017 12:00:00 AM	ADDRESS	34.29108	-118.5797	9/29/172ND CHANGE TO APPOVED SET. COMPLETE CHANGE TO THE SYSTEM IN SIZE AND EQUIPMENT . CHANGES MARKED UNDER R1 NEW SYSTEM SIZE 7.54KWAC/7.8 KWACSYSTEM INCLUDES 26 MODULES - HANWHA Q.PEAK- G4.1 30026 MICROINVERTERS ENPHASE IQ6PLUS-72-2-USTHIS IS PLAN CHECK ONLY!!Note: permit is paid under PCIS#16041-10000-3846701/18/17Changes to an approved set of plans. changes include removing 10 modules from roof-layout and single line diagram, replacing module type from Canadian solar CS6K-275M to LG 285S1C-G4, and using an AC combiner box instead of a panel load center. All changes are clouded under delta R1.(39)Modules-LG 285S1C-G4(39)microinverters-Enphase M250-60-2LL-S22 Note: permit is paid under PCIS#16041-10000-38467PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.475KWdc / 11.76KWac.(49)MODULES-CANADIAN SOLAR CS6K-275M(49)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6629	11041-10000-12679	2154 W SUNSET BLVD	90026	13	139-5A207 104	5402030016	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.07735	-118.26555	NEW FIRE ALARM SYSTEM FOR AN EXISTING 2-STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6630	13041-10000-22578	1875 CENTURY PARK EAST suite 1380	90067										Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	08/21/2013 12:00:00 AM				Office suite TI in highrise building.  T24 plan check only for lighting.  Permit to be issued at electrical plan check counter. work done in suite 1380	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6631	15041-10001-10551	11922 S VERMONT AVE	90044	15	084B197   351	6088020013	C2-1L	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	33.92425	-118.29139	**Supplemental Power PC and Permit: Install new Panel 225A.*Replacement of two incandolecent lights with florescent fixtures  in storage or prep room of Ralphs store, total area 290 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6632	18041-10000-23289	8001 N CANOGA AVE	91304	3	189B105   158	2110020004	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Issued	06/22/2018 12:00:00 AM	ADDRESS	34.21606	-118.59777	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6633	17041-20001-17044	6998 N SALE AVE	91307	12	183B101   870	2024025032	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM			PC Approved	05/30/2017 12:00:00 AM	ADDRESS	34.19753	-118.61718	Expedited per applicant request.Plan check for solar pv system, roof-mounted on SFD.4kW ungrounded system.(13) 330W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6634	19041-10000-48192	283 W IMPERIAL HWY	90061	8	087A203   236	6074024900	C2-1	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Apartment			12/19/2019 12:00:00 AM	01/14/2021 12:00:00 AM		Permit Finaled	04/16/2024 12:00:00 AM	ADDRESS	33.93116	-118.27894	INSTALLING A NEW 1200AMP SERVICE, PANELS, CIERUITS.PER BUILDING PERMIT #: 19010-10000-02202 (( 5 STORY MIXED USE, 54 UNIT APARTMENT BUILDING ITH COMMERCIAL ON THE 1ST FLOOR)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6635	18041-20000-36716	7037 N RESEDA BLVD	91335	3	183B125   454	2126008009	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.19878	-118.53624	pv2install roof mounted pv system sized 7.7KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6636	11041-20000-05743	17736 W HATTERAS ST	91316	12	174B129   151	2159029023	[Q]CR-1VLD	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.17656	-118.51992	Plan check 25.9KW roof mounted PV System on apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6637	18041-20000-45196	5011 N DEL MORENO DR	91364	3	171B113   530	2166044009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.16106	-118.57635	Plan check for PV roof mounted system, system size: 12.54kW DC, 10.65kW AC wtih 38 PV modules and 1 inverter(11.4kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6638	16041-10001-43717	1750 N GLENDALE BLVD	90026	13	144A209   317	5423005004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			10/24/2018 12:00:00 AM			PC Approved	10/24/2018 12:00:00 AM	ADDRESS	34.08713	-118.25942	This is plan check only, permit is covered under master #16041-10000-43717. Changes to approved set, noted as Delta-1 and Delta-5. Scope includes: revise unit feeders' length per field installation,  revise feeders' size accordingly, revise voltage drop accordingly, and revise unit numbering per field installation.<<PC for new five story apartment with 70 units with two levels of subtarrenean basement.  PC for new 3000 A, 120/208 service.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6639	10041-20001-22134	11651 W SHERMAN WAY	91605	6	183B169   112	2316030006	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	ADDRESS	34.20136	-118.38621	Original application 10041-20000-22134 abandoned. New plan check to install 600A service with (2) 200A gutter section with fuse disconnect and (1) 200A meter section, (1) 200A panel and load calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6640	17041-20001-43973	17806 W PLUMMER ST	91325	12	198B129    11	2766003038	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	34.24291	-118.5218	PV1.  Install 10.075 kW roof mounted grid tied PV system.  (31) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6641	17041-20000-18362	221 N FIGUEROA ST 9th FL.	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for energy only. Partial floor TI on 9th floor of high rise office building. New lighting (incl. emergency) - 17,285sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6642	15041-10000-16458	3901 S BROADWAY PL	90037	9	115-5A203  43	5122044001	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.01203	-118.27707	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED LIGHT FIXTURES. TOTAL AREA 5203 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6643	19041-10000-20153	12813 W BESSEMER ST	91606	2	177B161   754	2332030005	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.18041	-118.41208	PV1. NEW SOLAR SYSTEMS ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.775KWdc / 7.60KWac.(27)MODULES- HANWAH 325 W PANELS(27)OPTIMIZERS- SOLAREDGE P340(1)INVERTER-SOLAREDGE SE7600H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6644	19041-20000-46351	444 S FLOWER ST Ste 3860	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	TI to (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6645	19041-10001-09181	1401 S GRAND AVE	90015	14	124-5A207  21	5134017029	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Issued	10/23/2019 12:00:00 AM	ADDRESS	34.03721	-118.26568	CHANGE TO AN APPROVED SET. CHANGE INCLUDES UPSIZING THE MANLIFT SIZE AND UPDATING FAULT CURRENT CALC. CHANGE UNDER DELTA 1 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6646	12041-10000-21545	14658 W VENTURA BLVD	91403	5	166-5A149  71	2276002017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.15143	-118.45282	Ti for a new Beauty Salon in Suite #F.  EPC is for power & energy.   <According to the applicant, this is not Not a Medical Building>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6647	14041-10000-21131	8510 S LILIENTHAL AVE	90045	11	096B169   435	4107018017	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	33.96071	-118.38599	PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(15) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6648	12041-20000-14331	3909 S DENKER AVE	90062	8	117B193  1466	5036023014	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Apartment			06/20/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.01413	-118.30466	Roof mouted P.V. system (5.98 KWdc)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6649	17041-20000-40717	225 S LINCOLN BLVD	90291	11	111B145   529	4240019061	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.00183	-118.46926	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Existing grocery store is being expanded. Total lighting area = 3,646 sq. ft.Note: Building application has been generated under 17016-30000-19434	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6650	17041-10001-05673	2412 N NORTH BROADWAY	90031	1	138A221    97	5204005007	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			Corrections Issued	03/28/2017 12:00:00 AM	ADDRESS	34.07347	-118.21644	TI PC FOR T24 ENERGY ONLY. ADDITION AND NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6651	17041-10000-18656	2915 N CORDA LANE	90049	11	156B137    57	4490006039	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.12618	-118.48856	Installation of (1) new 200A load center with (1) 5.8 kVA  Tesla AC Powerwall battery for an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6652	19041-20000-18848	6436-6440 N PLATT AVE	91307	12	180B093   512	2036024053	(Q)C1-1VL, (Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL, C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.18785	-118.64248	Change of use from retail to medical office.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6653	15041-10000-27114	435 W BERNARD ST 1-7	90012	1	136-5A215 132	5414017031	C2-2D	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.06732	-118.23693	New mathane detection system, level 4. Bldg 1 of 2, retail space, 16 devices, 1 control panel. Plans start in sheet VC 12 per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6654	18041-20002-00858	7320 N HILLSVIEW CT	91307	12	186B089   513	2027047004	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.20479	-118.65146	Revision to approved set of plans.  Change of locations of equipment, additional subpanel for energy storage systems.  $0.00 plan check fee due to CA Senate Bill 1222(((PV1.  Install roof mounted pv system sized 10kw interconnected with msp with three tesla battery back up.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6655	12041-10000-07758	711 S HOPE ST 26TH  FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM			PC Approved	04/04/2012 12:00:00 AM	ADDRESS	34.04757	-118.25858	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTROOM TI ON GYMNASIUM/FITNESS AREA ON THE 26TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6656	13041-20000-06589	1253 N AMALFI DR	90272	11	129B133    53	4425007007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	34.05281	-118.50547	New 5.23kw PV system for an existing single family residence with a 600 amp service.  System Uses Backup Batteries.  (Batteries are charged under Dwelling App.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6657	16041-10000-35938	12911 W ADMIRAL AVE	90066	11	105B157   343	4223005002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	33.98535	-118.42926	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(30)MODULES-LG #LG315N1C-Z4(1)INVERTER-DELTA# SOLIVIA 7.6 TL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6658	18041-10000-29195	4370 S HOOVER ST	90037	9	112-5A201  48	5019009900	PF-1	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.00408	-118.28693	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6659	14041-20000-25454	21301 W BURBANK BLVD 2ND FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.17351	-118.59524	TI FOR FULL 2ND FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6660	15041-10000-03241	9504 N WHITAKER AVE	91343	12	198B133    42	2686020009	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM			Reviewed by Supervisor	03/13/2015 12:00:00 AM	ADDRESS	34.24325	-118.499	PV1 INSTALL 14.39 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (44) MODULES:  SUNPOWER SPR-327NE-WHT-D(2) INVERTERS: SMA SB 6000TL-US-12	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6661	15041-10000-04769	1550 N EL CENTRO AVE	90028	13	148-5A189 308	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			02/18/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.09961	-118.32359	Installation of new fire alarm system for the Residential Tower of the Columbia Square project - highrise residential with restaurant and retail at ground level.  939 devices total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6662	14041-20000-06061	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	33.97902	-118.43558	pv2 commercial rooftop. solar modules to be installed on new canopy. total of 60 modules. using 480V interconnection. interconnect to existing 300A service system size 13 kw AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6663	12041-10000-20345	5755 W 96TH ST	90045	11	093B169   128	4125021024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM			Verifications in Progress	11/16/2012 12:00:00 AM	ADDRESS	33.94955	-118.38214	ELECTRICAL UPGRADES FOR  THE 1ST FLOOR PRODUCTION AREANOTE THAT FEES DO NOT INCLUDE NEW CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6664	12041-20000-30345	444 S FLOWER ST 27th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	Change to lighting in the elevator lobby and corridor on the 27th floor of an existing high rise office building.  Occupancy load is less than 99 and load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  <<Contractor is doing work on several floors, cumulative load over 400 amps will require Full Plan Check subject to field inspection.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6665	12041-10000-05321	12100 W WILSHIRE BLVD flrs-12,16,19	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.0438	-118.46755	Change of lighting to an existing  elevator lobbies on floor floors 12, 16, and 19.Permit was obtained on separate application;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6666	16041-10002-37951	6929 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM			PC Info Complete	07/25/2018 12:00:00 AM	ADDRESS	34.19659	-118.49256	"[7/2/18 CHANGES TO APPROVED SET CLOUDED UNDER DELTA ""3"". CHANGES INCLUDE LIGHTING, ADDITION OF HVAC, EV CHARGERS AND REPLACING PANELS]]"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6667	08041-10001-19402	639 N BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Apartment			08/06/2012 12:00:00 AM			PC Approved	08/06/2012 12:00:00 AM	PIN	34.05985996	-118.23998637	CHANGES WERE MADE TO PERMITTED SET OF PLANS. BUBBLES ON REVISED SHEETS OF THE PLANS SHOW WHERE OPEN AREAS NEAR ELEVATOR SHAFTS WERE ENCLOSED. EM LUMINIRES REMAINED OR WERE RELOCATED NEARBY . ((((((New Mixed-Use apartment retail complex.  Permit is for new service, new panels, new dist. boards, new ckts, new equipment, new lighting fixutres.  P/C is for Power and Energy.   A variance to separate the electrical and fire alarm plan check and permitting was submitted on November 25, 2008.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6668	16041-20000-13987	3671 N BERRY DR	91604	2	162B173   918	2378025029	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM			Reviewed by Supervisor	05/06/2016 12:00:00 AM	ADDRESS	34.13712	-118.37878	Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 7.6kW. Ungrounded system. Each module has a 300W power optimizer.(33) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6669	13041-20000-31932	9822 N AURA AVE	91324	12	201B117   209	2761010034	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.24881	-118.5543	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC 48 MODULES AND 2 INVERTERS$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6670	11041-20000-18599	17748 W SATICOY ST	91335	3	186B129   263	2120031032	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Info Complete	01/05/2012 12:00:00 AM	ADDRESS	34.20825	-118.52039	New 600A service upgrade from 400A, new switchboard, and one new panel for an existing building.  Plan check is for power. No new load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6671	19041-20000-28965	6901 N LANGDON AVE	91406	6	183B145   605	2234026003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.19579	-118.46958	Plan check for PV roof mounted system, system size: 5.94KW DC, 5.386KW AC with 18 PV modules and 9 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6672	12041-10000-01130	500 W WORLD WAY 5M	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM			PC Approved	01/18/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check T24 Energy/Emergency lighting for retail space 5M at LAX Terminal 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6673	19041-20000-00061	18800 W SALT LAKE PL	91326	12	210B121   486	2717002046	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.27054	-118.54323	Plan check for PV roof mounted system, system size: 11.16kW DC, 9.95kW AC with 31 AC Modules and 1 load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6674	19041-10000-29733	7910 N SEPULVEDA BLVD	91402	6	189B145   456	2209032045	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.21442	-118.46594	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6675	17041-10002-32818	7348 N ETHEL AVE Units A&B	91605	2	186B161   541	2327015007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	PIN	34.20432132	-118.41768776	Supplemental for changes to approved set of plans under delta 2 only - changes include upsizing 2 transformers from 75kva to 150kva and 2 panels from 200A to 400A . Changes also include updating transformers and panels locations and modifying lighting fixture wattage.***original scopePlan check for power and energy. Project site is a new commercial building. Project scope is a first time tenant. Total lighting area = 2,208 sq. ft.Note: Building application has been generated under 16014-20000-04290	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6676	19041-20000-27706	19144 W MAYALL ST	91324	12	204B121   394	2729025026	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.25389	-118.55103	PV1.  Install 12.06 kW DC / 10.25 kW AC roof mounted grid PV system.  (36) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6677	11041-10000-22938	1599 E CAMPUS ROAD	90041	14	157-5A223   6	5474012025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00, 1834.00	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.12581	-118.21419	PV SYSTEM.(FRATERNITY HOUSE -MIXED USE OF GUEST ROOMS(5) AND OFFICE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6678	18041-10001-09270	3836 N HAYVENHURST DR	91436	5	162B141   231	2286021041	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.14043	-118.48528	Fees for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6679	14041-20000-13815	11810 W GLAMIS ST	91342	7	210B169   944	2530029015	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1041.08	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.2764	-118.38992	PV1.  PV system redesign. Electrical permit and plan check approval obtained previously under 14041-20000-12203 for microinverter system, now transformerless central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6680	13041-20001-35916	6900 N RANCHITO AVE	91405	2	183B153   882	2216019022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.1959	-118.43552	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELING. TOTAL SYSTEM SIZE 9KW AC USING TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. WITH POWER OPTMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6681	12041-20000-19997	1100 S GLENDON AVE 1800	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Expired	09/17/2014 12:00:00 AM	ADDRESS	34.06074	-118.44418	T.I. to existing high rise building on the 18th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6682	14041-20000-14466	21555 W OXNARD ST	91367	3	177B105    33	2146005177	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Expired	07/13/2016 12:00:00 AM	ADDRESS	34.17943	-118.59939	T24 FOR BREAKROOMS IN 12 STORY HIGHRISE OFFICEFLOORS 7, 10, 11, AND 12	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6683	18041-10000-45894	9430 N TOPANGA CANYON BLVD	91311	12	198B101   335	2746013041	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.24159	-118.60598	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6684	17041-10000-38390	11414 W KELOWNA ST	91342	7	213B173   220	2530031008	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.27976	-118.3795	Install new rooftop solar on a SFD, 11.4 kW AC, (45) modules with power optimizer one on one, (1) inverter	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6685	14041-20000-27931	6944 N YARMOUTH AVE	91335	3	183B129   625	2122001011	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.19694	-118.51954	PV1 SFD. TOTAL SYSTEM SIZE 4KW AC USING 19 MODULES. USING MICROINVERTER SYSTEM WITH ENPHASE M215. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6686	19041-20001-06488	341 S WESTGATE AVE	90049	11	132B141  1049	4404036008	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.0566	-118.47167	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 21.24 kWdc/18.9 kWac and consists of (59) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6687	18041-10000-13526	8039 N CANOGA AVE	91304	3	189B105   112	2110020012	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Issued	04/13/2018 12:00:00 AM	ADDRESS	34.21629	-118.59771	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6688	10041-10000-23054	8460 N RESEDA BLVD	91324	12	192B125   317	2786021011	C2-1VL, P-1VL	North Valley	Northridge			1154.02	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	ADDRESS	34.22435	-118.53588	"CHANGE 24'-8""X 78'-6""OF RETAIL/ AUTO REPAIR AND AUTO UPHOLSTERY SHOP  TO RESTAURANT. LIMIT HOURS OF OPERATION FROM 7:00 AM TO 11:00 PM."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6689	12041-10001-07685	355 N LA CIENEGA BLVD	90048	5	138B173   165	4337012028	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.07769	-118.37679	Plan check T24 Energy/Emergency lighting for massage parlor. Less than 400A installation and non-health care facility. Permit for additional branch ckts (sign, show wondow, and water heater) and outlets on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6690	13041-20000-01990	7033 N RESEDA BLVD	91335	3	183B125   454	2126008009	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.19864	-118.53624	Change of use from office to Medical Office (Dental),  Stand-alone building.  NOT a State Licensed Office.  (Not OSHPD).  Install new 225A panel.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6691	19041-10000-22014	900 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Issued	07/15/2019 12:00:00 AM	ADDRESS	34.04526	-118.26611	"T-24 PC FOR A TI OF HOTEL LOBBY ON LVL 1 AND CLUB LOUNGE ON LEVEL 23. REPLACING CHANDALIERS AND ADDING DIMMERS TO ELV LOBBIES ON LEVELS 2, 3, & 22 THRU 26. AREA IS 16119 SQ.FT***NOTE: PER CONTRACTOR'S REQUEST, THE ""LOBBY"" WILL NO LONGER BE INCLUDED IN THIS PERMIT. A DIFF PERMIT SHALL BE OBTAINED FOR THE LOBBY.****B#19016-10000-09529"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6692	17041-20000-30187	8334 N WILBUR AVE	91324	12	192B121   680	2785019015	RA-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.22158	-118.54464	Plan check for solar pv system, roof-mounted on SFD.9.52kW ungrounded system.(34) EnPhase IQ6PLUS-72-2-US microinverters.(34) 350W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6693	15041-10000-33384	5792 W JEFFERSON BLVD	90016	10	120B173   313	4205031004	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.02554	-118.37522	PC FOR POWER AND ENERGY. TI FOR WEWORK. UPGRADING SERVICE FROM 1200 A TO 2000A.  NO CHANGE OF USE( OFFICE). TOTAL AREA 27143 SQ (CONDITIONED).B# FOR CORE AND SHELL 15016-10000-10510. BUILDING APP UNDER DIFFEENT APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6694	18041-10000-48441	223 W ALPINE ST	90012	1	135A215   360	5408030009	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.0622	-118.23761	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6695	16041-10000-09047	4160 W WILSHIRE BLVD STE# 201	90010	4	132B189    85	5092001046	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.06152	-118.31825	"CHANGE OF USE & INTERIOR REMODEL TO AN (E) VIP PLASTIC SURGERY OFFICE. SCOPE OF WORK INCLUDES THE ""PROCEDURE ROOM"". AREA: 1,286 SQ. FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6696	16041-10000-12315	7945 N VAN NUYS BLVD	91402	6	189B149   374	2210019015	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM			PC Approved	06/07/2016 12:00:00 AM	ADDRESS	34.21552	-118.44896	T-24, COMMERCIAL EXTERIOR AND INTERIOR ALTERATIONS TO AN (E) RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6697	17041-20002-01171	13767 W FOOTHILL BLVD	91342	7	225B153   444	2509015007	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.31003	-118.43331	6/15/17changes to an approved set of pans.  changes include updated series rating breakers to reflect field conditions.this is plan check only. 05/30/17Changes to an approved set of plans. All changes are clouded under delta 2. Changes include relocating electrical panels on the floor plans, removing/replacing lighting fixtures for indoor/outdoor, adding daylight controls for skylights, revising title 24 calculations, revising panel schedules, and revising load calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6698	14041-10001-28254	939 S BROADWAY	90015	14	127-5A209 285	5139003006	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	34.04157	-118.25708	Revision to approved set, change the conductors type from Copper from Aluminum on all feeders from Switchboard MSA downstream. Voltage drop and fault current are revised as well.(Master Plan checker: Mr. Zandi)<<<PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO LIVE WORK. 12 STORY, HIGH RISE. 151 UNITS. Building P# 13016-10000-15414 .CHANGE OF USE OF 12-STORY LIGHT-MANUFACTURING FOR GARMENT INDUSTRY AND BASEMENT STORAGE TO  ADAPTVE REUSE LIVE WORK UNITS. CHANGE OF USE OF PORTION OF FIRST FLOOR RESTAURANT AND RETAIL TO 8 JOINT LIVE AND WORK QUARTERS.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6699	18041-10000-04276	10626 W ERWIN ST	91606	2	177B177   299	2414016001	R1-1, RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.18289	-118.36228	PC for T24 only for replacement of outdoor metal halide fixture with new LED fixtures. Total area 34000sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6700	11041-10002-24488	1056 S FREDERICK ST BLDG 2-2	90291	11	111B145   881	4243003032	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/26/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	33.99912	-118.46	Lincoln Place Apartment Building Project.  New 2-story apt. building with 8 units.   Addition of three E>V> and a 200 amps sub panel , meter added to the existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6701	18041-20000-19201	3957 N VAN NOORD AVE	91604	2	162B161   342	2385030011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Issued	05/23/2018 12:00:00 AM	ADDRESS	34.14195	-118.41477	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (31) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6702	15041-20002-40750	350 W 5TH ST Unit 208	90731	15	015B201    39	7455014035	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	33.73981	-118.28471	03/04/2016 Plan check for power and revised lighting. Project site is existing commercial building. Project scope is a change of use from office to medical office/tenant improvement. Permit is to be pulled for additional equipment not covered under initial express permit. Total lighting area = 1,820 sq. ft.Note: Building permit has been pulled under 15016-30000-16139*****Previous Work Description*****Plan check for Title 24 only for Medical office. Total area: 1,820 sqft. (((((INSTALL 40 OUTLETS FOR OFFICE)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6703	19041-10000-12761	6222 W WILSHIRE BLVD #101	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM	ADDRESS	34.06309	-118.36418	Full PC for new dental office (change of use) ,  Area of work is 1758 sqft (High Rise Building).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6704	19041-10001-45907	1253 N BISHOPS ROAD	90012	1	136-5A215  10	5414019011	[Q]R3-1	Central	Central City North	Historic Cultural North		2060.10	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM			PC Approved	06/25/2020 12:00:00 AM	ADDRESS	34.06976	-118.23428	EXPEDITE FEESPV2, NEW COMMERCIAL ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 255.8KWdc/173KWac. SCOPE OF WORK IS TWO PV SYSTEMS. SYSTEM ONE IS 425 MODULES (HANWHA 390), FIVE CENTRAL INVERTERS (THREE SMA STP 20000, ONE SMA STP 24000, AND ONE SMA STP 30000), ALL LEADING TO TWO SUBPANELS, AND A BATTERY BANK AT 30KW. CONNECTED TO AN EXISTING 2000A SERVICE SYSTEM ONE IS 221 MODULES (HANWHA 390), THREE CENTRAL INVERTERS (ONE SMA STP 20000, ONE SMA STP 24000, AND ONE SMA STP 15000), ALL LEADING TO TWO SUBPANELS, AND A BATTERY BANK AT 30KW. CONNECTED TO AN EXISITNG 12000A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6705	16041-20000-42774	3886 N CARPENTER AVE	91604	2	162B169   534	2369025007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			Reviewed by Supervisor	12/14/2016 12:00:00 AM	ADDRESS	34.14004	-118.3919	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6706	17041-20000-43567	1511 N SUMMITRIDGE DR	90210	5	147B157   141	4355004014	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM			Reviewed by Supervisor	01/05/2018 12:00:00 AM	ADDRESS	34.09928	-118.42133	New single family dwelling with 800A service.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6707	13041-10001-29526	2734 S NORMANDIE AVE	90007	8	123B197  1486	5054006008	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Apartment			10/23/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.02987	-118.30006	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6708	16041-20000-35539	700 S FLOWER ST Suite 580	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Issued	10/11/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for energy only. TI to office - suite 580 - on 5th floor of high rise building. New lighting (incl. emergency) and receptacles. 1,217sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6709	12041-20000-08771	400 S HOPE ST	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Info Complete	04/17/2012 12:00:00 AM	ADDRESS	34.05199	-118.25366	TI for an office. High rise building. Plan check for energy and emergency lighting. 8155 conditioned sqft.#12041-20000-08771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6710	10041-10001-13799	1999 S AVENUE OF THE STARS 20TH FL	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM			PC Approved	11/02/2010 12:00:00 AM	ADDRESS	34.05886	-118.41642	DELTA 2 REVISIONS- CHANGED A COUPLE TYPES OF LUMINAIRES AND INCREASED THE INSTALLED WATTAGE. REMODELING OF OFFICE SPACESPLAN CHK IS FO RTITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6711	09041-10001-05793	5950 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	02/17/2010 12:00:00 AM		Permit Finaled	03/04/2010 12:00:00 AM	ADDRESS	33.94286	-118.38591	as-built set of plans- in the cargo facility area, adding new circuits for battery chargers, dock levers and other motor loads. all changess are shown  bubbled on the plans	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6712	11041-10000-11359	19260 W NORDHOFF ST	91324	12	198B117   233	2784001023	(Q)C2-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			Corrections Issued	06/11/2011 12:00:00 AM	ADDRESS	34.23522	-118.55294	Existing gas station.  New canopy is being installed over a new distribution station.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6713	11041-10000-09809	429 S WESTERN AVE	90020	4	135B193   553	5503015006	C2-1	Central	Wilshire			2117.02, 2118.01	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	11/09/2011 12:00:00 AM	ADDRESS	34.06619	-118.3093	REPLACE AN (OLD / DAMAGED ) EXISTING 600 AMP SERVICE AND PANELS IN A COMMERCIAL BUILDING. (EXISTING LIGHTS). PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6714	14041-20001-11633	17405 W HORACE ST	91344	12	210B129   637	2712006021	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.26984	-118.51336	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 7.41kW(1) SMA America SB3800TL-US-22 transformerless inverter(1) SMA America SB4000TL-US-22 transformerless inverter(33) Suniva OPT260-60-4-1B0 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6715	13041-10000-33455	100 N SAN VICENTE BLVD	90048	5	138B173  1322	4334007009	C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.07487	-118.37833	replacement of a 10HP ventilation fan motor with a 5HP fan motor.Wiring in Class I Div2 occurs above a building. Disconnect will be within sight on the roof and Listed same as the motor for use in Class I Div 2 locations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6716	10041-10000-15838	1651 E BAY ST	90021	14	123A215   248	5166035***	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	03/25/2011 12:00:00 AM	ADDRESS	34.03212	-118.23658	New 75KW PV system on a commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6717	11041-20000-17501	15260 W VENTURA BLVD 1020	91403	5	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	09/14/2011 12:00:00 AM	ADDRESS	34.15356	-118.4658	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TI OFFICE #1020Fire/ Life safety by others 11041-20000-16130	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6718	14041-10000-06606	3448 W FERNCROFT ROAD	90039	13	153A207   218	5437022009	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.11319	-118.26351	PV1 3.672KWac. 240V. microinverter. STD. 1story. Roofmount. [(17) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(17)modules: {SHARP 250W ND-250QCS}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6719	19041-20000-16084	20742 W BEECH CIR #309-pv1	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.2936	-118.58555	pv1install roof mounted pv system sized 3.02KW ACinterconnected with msp.(9)ACM at 335W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6720	18041-10001-06316	10250 W SANTA MONICA BLVD 2000	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	SUPPLEMENTAL CHANGES TO APPROVED SET CHANGES ONLY APPLY TO DELTA 9 AND 10.  ADDING LIGHTING AND RELOCATION, REDUCING LOADS. note: PERMIT HAS BEEN PULLED ON MASTER APPLICATION. PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6721	13041-10001-29431	19601 W GILMORE ST	91335	3	180B117   773	2132013018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.18763	-118.56013	Expedited RSES plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6722	13041-20000-21114	3620 S VERMONT AVE 200-210	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.02213	-118.29133	T24 FOR EXSTING NON HIGHRISE OFFICE SPACE. TOTAL SQRFT 1500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6723	15041-20004-30865	687 S HOBART BLVD	90005	10	132B193   184	5093006033	(T)(Q)C2-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			PC Approved	11/16/2017 12:00:00 AM	ADDRESS	34.0605	-118.30557	11/17/2017changes to an approved set of plans.  changes noted delta 3.  changes to reflect field conditions.  this is plan check only.PC FOR POWER AND ENERGY. NEW MIXED USED BUILDING. 7-STORY, 346 UNITS. 32 TYPICAL UNITS.  2  PARKING LEVEL ABOVE GROUND AND ONE SUBTERRANEAN LEVEL. TOTAL AREA 254860 SQ FT.address has been updated to match building permit. 11/9/15	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6724	17041-20000-00847	361 N GENESEE AVE UNIT # 1-4	90036	5	138B177   116	5527039008	RD1.5-1-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.07783	-118.35871	PLAN CHECK FOR POWER AND ENGERGY.  NEW 4 UNIT APARTMENT 3 STORY, 2 TYPICAL UNITS. 4,212 SQFT.Note: Building permit has been pulled under 14010-20000-02405	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6725	16041-10000-42698	18450 W INGOMAR ST	91335	12	189B125   737	2102021901	R3-1, RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.2119	-118.53495	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total sqft = 40600.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6726	19041-20000-43221	21300 W VICTORY BLVD Ste 800	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.18813	-118.59618	New lighting and power for (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6727	13041-10000-21125	19326 W COHASSET ST	91335	3	186B117   972	2116016088	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.20639	-118.55453	PV1 4.536KWAC 5.15kwdc 240V MICROINV 2STORY. nonSTD. ROOFMOUNT.[( 21) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: yingli {YL245-29b}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6728	13041-10000-09715	11811 W DARLINGTON AVE 1-26	90049	11	129B145   313	4265017032	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.05105	-118.46642	FIRE ALARM SYSTEM FOR 26 UNIT APARTMENT COMPLEX. TOTAL OF 119 DEVICES AND 2 PANELS. NEW SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6729	18041-10000-27208	11538 W PICO BLVD	90064	11	123B153   533	4260034005	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.03294	-118.44276	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6730	17041-10001-17892	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	05/30/2017 12:00:00 AM		Issued	05/30/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	Miscallenous permit for conduit only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6731	19041-20000-37372	3733 N DELLVALE PL	91436	5	162B137   452	2293003012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.13856	-118.49488	PV1. INSTALL 15.360 KW DC ROOFMOUNTED SOLAR SYSTEM WITH (48) MODULES AND OPTIMIZERS, (2) INVERTERS (SE7600H-US) AND (1) LG STORAGE BACK-UP BATTERY.FEES $0.00 DUE TO CALIFORNIA SENATE BILL 1222 AND AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6732	14041-20000-00462	5763 W CAZAUX DR	90068	4	153A191    64	5580024021	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.1151	-118.31473	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.4KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6733	15041-10000-20699	12020 W WILSHIRE BLVD	90025	11	126B145   137	4263003012	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.04468	-118.46646	Energy plan check for a 2-story building; Scope includes new light in a total area of 1159-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6734	11041-10001-03846	8340 S LINCOLN BLVD	90045	11	096B157   267	4113016018	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM			PC Approved	03/21/2011 12:00:00 AM	ADDRESS	33.96181	-118.42071	INSPECTOR TOLD CONTRACTOR THAT EMERGENCY LIGHTING WAS NECESSARY.  PHOTOMETRICS WAS SUBMITTED.  CUSTOMER IS USING BUG EYES WITH 90 MINUTE BATTERY BACK UP.   PLAN CHECK WAS FOR EMERGENCY LIGHTING. <<<<<<<<<<<TI.   TITLE 24 ONLY ON AN EXISTING GROCERY STORE.  PERMITS HAVE ALREADY BEEN PULLED, PER CONTRACTOR.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6735	12041-10000-06814	901 W OLYMPIC BLVD	90015	9	129A207   293	5138005036	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Closed	05/12/2014 12:00:00 AM	ADDRESS	34.04576	-118.26609	TEMPORARY CONSTRUCTION POWER FORTHE CONSTRUCTION OF THE NEW MARRIOTT HOTEL;PLAN REVIEW  FOR THE SERVICE, CRANE, FIRE PUMP. MAN-LIFT, SKIDS AND ELEVATORS-ALL PART OF THIS CONSTRUCTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6736	14041-20000-25062	20215 W INGOMAR ST	91306	3	189B113  1354	2107021076	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.21165	-118.57358	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW.(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(19) Kyocera KD255GX-LFB3 pv modules(19) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6737	11041-10000-09218	116 N ROBERTSON BLVD	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.0758	-118.38356	Ti in an existing retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6738	15041-20000-05340	6316 N TOPANGA CANYON BLVD SUITE 1110	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. XOC TEQUILA GRILL. WESTFIELD TOPANGA MALL. SUITE 1110	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6739	16041-10000-23166	6708 N BIANCA AVE	91406	6	180B129   183	2229010035	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Expired	08/08/2018 12:00:00 AM	ADDRESS	34.19237	-118.51298	PV1. AN ADDITION TO AN EXISTING SOLAR SYSTEM FOR A SINGLE FAMILY DWELLING. ADDING 3.8KWAC TO AN EXISTING 3.8KWac SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS 7.6KWac.(15)MODULES-KYOCERA #KU2606XPA(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6740	17041-10000-09201	5800 W SUNSET BLVD 1ST FLR-3R FLR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			PC Info Complete	03/22/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PC FOR TITLE 24. INSTALLING NEW LIGHTS AND CONTROLS FOR FLOORS 1st-3rd. TOTAL AFFECTED AREA 19430 SQ.FT.Emergency and exit lights not part of the scope of this project.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6741	16041-10004-15022	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM			PC Approved	12/12/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	11/18/16PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGESARE CLOUDED AND NOTED UNDER DELTA DCN-007. CHANGES INCLUDE REMOVING PANELS, REMOVING TRANSFORMER, REMOVING LIGHTING FIXTURES ON FLOOR PLANS, AND REVISING TITLE 24 CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6742	13041-20000-35518	1103 S ABBOT KINNEY BLVD	90291	11	108B145  1025	4239022002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	ADDRESS	33.99185	-118.47029	PC FOR T24 ENERGY ONLY. EXISTING RETAIL, NEW LIGHTING IN 2 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6743	10041-20000-15061	633 W 5TH ST 52nd Floor	90071	9	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	09/22/2010 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check T-24 Energy (general/lighting) office TI on the 52nd FL at US Bank Tower. Existing lighting ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6744	17041-20000-04961	353 S BROADWAY	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.04991	-118.24934	Facade lighting for commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6745	10041-10000-21869	7902 N VAN NUYS BLVD 2	91402	6	189B149   641	2212028022	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	01/05/2011 12:00:00 AM	ADDRESS	34.21453	-118.44848	TI WORK FOR FROZEN YOGURT; TAKE-OUT ONLY (NO SEATING)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6746	14041-20001-01879	4156 N HAYVENHURST AVE	91436	5	165B137   400	2291013015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/02/2014 12:00:00 AM	ADDRESS	34.14659	-118.49713	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING 30 MODULES. TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6747	19041-10000-27233	1064 W 39TH PL	90037	8	117B197  1012	5037022012	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.01402	-118.29366	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 3.48 SYSTEM CONSISTING OF 12 MODULES USING 12 MICROINVERTERS(IQ7PLUS-72-US) RATED AT 290W EACH CONNECTED TO  NEW 200A SERVICE. NOTE: Panel upgrade shall be permitted seperately by express permit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6748	17041-10000-21873	11401 N PORTER RANCH DR BLDG 10	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	03/01/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 15 unit apartment with 1,200 amp 208 volt service.       Building 10 of 10.  Type II.       Building permit #17010-10000-02387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6749	16041-20001-15065	11232 W BRIARCLIFF LANE	91604	2	156B169   205	2381020015	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM			PC Approved	06/03/2016 12:00:00 AM	ADDRESS	34.12622	-118.3803	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20.48 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6750	17041-10000-22467	835 W JEFFERSON BLVD Ste 1730	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.02411	-118.28451	Plan check for power and Title 24.  T.I. to existing restaurant with new outside dining area.  New connected load > 400 amps.  Lighting area = 3,546 sq. ft.       Building permit #17016-10000-17868	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6751	19041-20000-07490	18742 W COLLINS ST	91356	3	174B121   272	2156024033	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Issued	03/01/2019 12:00:00 AM	ADDRESS	34.17439	-118.54232	PLAN CHECK FOR ADDITION TO EXISTING ROOF MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM ADDITION SIZE IS  4.350 KW DC/3.19 KW AC. SCOPE OF WORK INCLUDES (11) LG NEON2 LG395N2W-A5 MODULES WITH ENPHASE IQ7PLUS-72-X-US 240VMICROINVERTERS AND (1) NEW 100A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6752	14041-10000-34286	11328 W GOSS ST	91352	6	192B173   432	2632005006	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.22252	-118.37775	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH  LED FIXTURES. TOTAL AREA 2076 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6753	19041-10000-42091	10416 S WILMINGTON AVE	90002	15	090A215   281	6066001019	C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	33.94099	-118.23889	PLAN CHECK FOR NEW ROOFMOUNTED PV1 SYSTEM . SYSTEM SIZE IS 3.72 KW DC; 3.8 KW AC; 12 MODULES (CANADIAN SOLAR 310 WATT MODULES), 12 OPTIMIZERS (SE P320) AND 1  CENTRAL INVERTER (SOLAR EDGE 3.8 KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6754	13041-10000-19429	307 W PACIFIC COAST HWY	90744	15	036B205   998	7421024014	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM			PC Approved	07/23/2013 12:00:00 AM	ADDRESS	33.7912	-118.26599	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING FOR AN EXISTING WAREHOUSE. 277 V LIGHTING.  APPLICATION WAS CHANGED TO PLAN CHECK ONLY ON 7/25/13. APPLICATION IS ASSOCIATED WITH PERMIT NUMBER 13041-10000-19447.  APPLICAION SHOWS APPROVED ON 7/23/13	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6755	14041-10000-04881	13553 W POLK ST	91342	7	231B157   386	2582011024	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.32596	-118.42969	PV1. ROOFMOUNTED SOLAR SYSTEM.  STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 3.57 KW DC.( 14) SUNMODULE SW 255 (14) ENPHASE M215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6756	16041-10001-45039	1425 E 54TH ST	90011	9	108B209   413	5104009022	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	33.99403	-118.24936	EXPDITED FEE PER APPLICANT REQUEST ********************************************PC FOR PV 3.0KW (AC)SYSTEM INCLUDEONE CENTERAL INVERTER  ABB-PVI 3.015 MODULES REC# ERC260PEZ	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6757	18041-10000-14172	9101 W LA TUNA CANYON ROAD	91352	7	198B185   199	2545024008	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.23661	-118.33153	NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM. SYSTEM SIZE: 34.3 KWdc / 27.4KWac(98) ENPHASE IQ6PLUS-72-2-US(98) SOLARWORLD SW350XL MONO	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6758	18041-10001-20923	20739 W DEARBORN ST	91311	12	198B109   144	2748036022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Approved	07/30/2018 12:00:00 AM	ADDRESS	34.23733	-118.58579	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 75.55 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6759	18041-20000-26959	401 E SHERMAN CL	90291	11	105A145    38	4227012001	RW1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	33.98348	-118.46546	pv1install roof mounted pv system sized 7.5KW AC interconnected with msp.(21) LG 360q1c-A5 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6760	17041-10000-30170	21515 W DEVONSHIRE ST	91311	12	204B105   174	2722007104	P-1, R3-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.2574	-118.59902	PC for T24 only for dollar tree store with 9775 sqft.  Total load under 400A. Installing three new panels with HVAC and new circuits.CEIS 785079COMPLY WITH DEPARTMENT ORDER effective date09/15/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6761	17041-20000-37934	18372 W CLARK ST ste 201	91356	3	171B125     7	2160008037	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.16959	-118.53283	ti to an existing dental office.  full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6762	16041-10000-12136	222 N MARIPOSA AVE	90004	13	138B197   380	5518011002	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.01	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM			PC Info Complete	09/14/2016 12:00:00 AM	ADDRESS	34.07605	-118.29926	PC FOR POWER AND T24.  NEW 2 STORY, TYPE III-B OFFICE BUILDING, 3,360 SQFT. 400 A SERVICE.B# 15010-10000-02761	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6763	15041-10000-43880	658 E VENICE BLVD	90291	11	108B145  1620	4237002006	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	33.98963	-118.46093	PC FOR FIRE ALARM MONITORING SYSTEM. INSTALLING NEW FIRE ALARM PANEL WITH 10 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6764	15041-10000-32877	1640 W SEPULVEDA BLVD STE 103 &-104	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Expired	04/17/2018 12:00:00 AM	ADDRESS	33.8166	-118.30825	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE), SUITES 103 &104. SCOPE INCLUDES NEW LIGHTING, AND THREE 225A NEW PANELS. TOTAL AREA IS 1644 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6765	17041-10000-29952	1000 S GLENDON AVE	90024	5	132B153  1096	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.06229	-118.44392	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF EXISTING FIXTURES WITH NEW LED FIXTURES. LIGHT REDUCTION <50%	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6766	10041-20000-25883	22142 W SHERMAN WAY	91303	3	183B101   109	2024012003	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.20073	-118.60949	Convert from school to dental office.  Install new optional standy-by generator, ATS, distribution board, and subpanels.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6767	17041-20000-34474	14329 W JOY DR	91331	6	198B153  1034	2644027246	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24147	-118.44553	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6768	10041-20000-11977	8126 W MELROSE AVE	90048	5	141B173   460	5528010001	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM			PC Approved	06/23/2010 12:00:00 AM	PIN	34.08347203	-118.36676186	"""AS BUILD "" PLANS( rev. to 09041-20001-22685 )."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6769	12041-10000-08688	370 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Expired	12/02/2014 12:00:00 AM	ADDRESS	33.93089	-118.26698	PLAN CHECK NEW 20.5KW ROOF MOUNTED AND GROUND MOUNTED PHOTOVOLTAIC SYSTEM FOR APARTMENT BUILDING. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6770	11041-10000-14297	759 S VERMONT AVE	90005	10	132B197   403	5094011021	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.05813	-118.29183	CHANGE OF USE FROM RETAIL TO ICE CREAM SHOP.  REPLACING EXISTING WATER HEATER WITH NEW, AND OTHER EQUIPMENT.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6771	14041-20001-35149	7033 N MIDDLESBURY RIDGE CIR	91307	12	183B089   161	2028046014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.19997	-118.64599	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main breaker to 150A.System size: 10kW (5+5). Ungrounded system.40  250W pv modules across 6 strings (inv1 has 7+6+6; inv2 has 7+7+7).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6772	19041-20000-50266	110 E 9TH ST 2nd Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TI to commercial tenant spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6773	16041-10001-18139	450 S WESTERN AVE #205	90020	10	135B193   649	5503014020	R3-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			Corrections Issued	06/13/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	FULL PLAN CHECK FOR FIRST TIME TENANT. PERMIT AND TITLE T24 ALREADY ISSUED. THIS IS PLAN CHECK ONLY FOR POWER SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6774	11041-10000-08459	800 S FIGUEROA ST	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			PC Approved	05/23/2011 12:00:00 AM	ADDRESS	34.04771	-118.26116	TI TO AN EXISTING OFFICE BUILDING ON THE 11TH FLOOR.  T-24 WITH EMERGENCY LIGHTING.  OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6775	12041-10000-19444	21505 W RINALDI ST	91311	12	210B105   275	2723004020	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM			Verifications in Progress	12/19/2012 12:00:00 AM	ADDRESS	34.27132	-118.59951	PLAN CHECK POWER AND ENERGY. NEW SINGLE STORY CLASSROOM BLDGS (BLDG 3). (APPLICATION 4 OF 6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6776	14041-10000-34703	5307 W 8TH ST	90036	4	132B181   220	5089001010	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM			PC Approved	12/15/2014 12:00:00 AM	ADDRESS	34.06064	-118.34513	Plan check for Title 24 only. Scope of work is existing commercial space (salon). Total lighting area = 608 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6777	14041-20009-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			07/02/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Closed	05/11/2020 12:00:00 AM	ADDRESS	33.95713	-118.3847	7/2/18changes to an approved set of plans.  changes noted delta 13 only.  changes to include new panels new circuits and relocation of existing equipment.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6778	10041-20000-23601	3700 N COLDWATER CANYON AVE	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	09/14/2012 12:00:00 AM	ADDRESS	34.13809	-118.41286	New fire alarm for Taper Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6779	18041-10000-05281	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC for T24 only for sign lighting. Installing new LED signs in food court area in LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6780	14041-20000-03877	3512 S MCKINLEY AVE	90011	9	115-5A209 169	5114013025	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.01132	-118.26062	PV2, MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 2KW AC USING TRANSFORMERD INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6781	15041-10000-24183	2011 S WESTWOOD BLVD	90025	5	129B153  1025	4323003015	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.0463	-118.43402	. CHANGE OF USE TO RESTAURANT. ADDED LOAD IS LESS THAN 400APLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6782	16041-10001-40425	12610 W RAYMER ST	91605	2	186B161   571	2324003021	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.2033	-118.4078	SEE APPLICATION COMMENTS. PC FOR CHANGES TO APPROVED SET UNDER DELTA 6 ONLY. SCOPE OF CHANGES INCLUDES:RELOCATION OF ELECTRICAL ROOM, ADDITION OF CIRCUITS, RECEPTACLES, CANGES TO LIGHTING AND LOADING AND CHAGES TO ELEVATOR TYPE AND DISCONNECT.    Full plan check for a  new 3 story commercial self storage building with 600 amp service.  Total area = 25,946 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6783	17041-10000-22812	19805 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	33.85117	-118.28712	TITLE 24 ONLY SCOPE INCLUDES - REMOVE HID FIXTURES(3) AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA (3450 SQ. FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6784	19041-10000-09544	1147 S WESTERN AVE	90006	10	129B193   861	5080003038	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.04955	-118.30926	T-24 PLAN CHECK FOR A TI TO A  RESTAURANT. ( Change the use of Take-out Restaurant and Retail to Restaurant per building application). SCOPE INCLUDES NEW 200A  SEVICE, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 675 SQ.FTB# 18016-10000-04373	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6785	14041-20001-14075	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.03497	-118.45709	supplemental permit under original permit number 14041 20000 14075 for modifications to lighting noted delta 5 on new plans.Remodeling of single-story commercial office building on campus.  Existing service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6786	14041-20000-00938	23501 W OXNARD ST	91367	3	177B093   709	2035003057	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.17891	-118.63877	NEW PV SYSTEM FOR AN EXISTING SFR.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6787	18041-10000-15248	14006 W RIVERSIDE DR SPACE 272	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	Changes to approved set. plancheck only.  noted as Delta-6. Scope incudes: revise luminaires mounting details, revise lighting position per ceiling and walls; add three circuits, and relocate panel.<<<Energy plan check for a retail T.I located in a commercial (Mall) building. Scope includes new lighting and equipment.  Total area is 5,290 SQ FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6788	11041-10000-00444	3050 W LOS FELIZ BLVD	90039	13	157-5A207 222	5435017016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM			Corrections Issued	02/22/2011 12:00:00 AM	ADDRESS	34.12467	-118.2659	Change from mini mart to 7-11. New 600 service. New panels & branch cicuits. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6789	17041-20001-28607	11111 W CUMPSTON ST	91601	2	174B173  1268	2350003061	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			02/28/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	ADDRESS	34.17011	-118.37286	02/25/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. Electrical room has been revised.*****Previous Work Description*****new 4 story 41 unit apartment building 1600 amp service.  plan check for power and energy.building permit number 14010-10000-03680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6790	17041-10000-20202	3411 E SISKIYOU ST	90023	14	121-5A227 186	5188017029	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.02663	-118.20114	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6791	18041-20000-39629	5808 W SUNSET BLVD 2ND FLOOR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM			PC Info Complete	10/16/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check for Title  24 only in existing high-rise building, T.I. portion of 2nd Level . Total area: 2724 sq ft. B#18016-10000-20254	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6792	17041-10002-03201	1942 S POINT VIEW ST	90034	10	126B173   749	5066016025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.04073	-118.37336	CHANGES TO APPROVED SET OF PLANS. CHANGES under delta 2. changes  INCLUDE  ADDITION OF sub panel (200A) and connection to existing house panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6793	10041-10000-18697	406 S RAMPART BLVD 1-60	90057	1	135A203   173	5155028011	R4-1	Central	Westlake		YES	2087.20	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.06459	-118.27965	New 600 Amp service and board. Plan check for power. No new loads were added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6794	12041-10000-19712	520 S VIRGIL AVE 4th floor	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM			PC Approved	08/22/2012 12:00:00 AM	ADDRESS	34.06457	-118.28687	T.I. to an existing 5-story office building.  Load is less than 400Amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6795	18041-20000-18413	14849 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29465	-118.45494	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.87kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6796	18041-20002-19219	9857 N MASON AVE	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Apartment			11/07/2019 12:00:00 AM			PC Approved	02/19/2020 12:00:00 AM	ADDRESS	34.24955	-118.58012	Power and energy plan check for first time tenant. (((TI IN AN EXISTING STARBUCKS COFFEE. INSTALL LIGHTS, PANELS & CIRCUTS.PLAN CHECK FOR T-24 ENERGY ONLY.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6797	18041-20000-43615	6936 N PEACH AVE pv1	91406	6	183B145   480	2234024027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.19675	-118.46824	pv1install roof mounted pv system sized 12.9KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6798	15041-20000-14026	2303 S FIGUEROA WAY	90007	1	123A203   162	5124028010	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM			PC Approved	05/08/2015 12:00:00 AM	ADDRESS	34.03049	-118.27509	Plan check for Charter School Title 24 only addition reception. Total area: 1,205 sq ft.PC only, Permit fees paid under 15041-10000-25389	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6799	11041-10000-23598	2250 S BARRINGTON AVE	90064	11	123B149   488	4260013028	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.0331	-118.44665	"T.I. improvement for a ""Dog Hotel"", previous use was manufacturing.  FULL Plan Check.  Fire alarm to be on a seperate application."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6800	18041-10000-45928	1830 W PICO BLVD	90006	1	129A203   433	5135005001	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Issued	12/04/2018 12:00:00 AM	ADDRESS	34.04582	-118.27988	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6801	15041-20001-27141	13812 W DAVANA TER	91423	4	165B153   840	2266022005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1411.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	09/15/2015 12:00:00 AM	ADDRESS	34.14636	-118.43389	Expedited per customer request.PV1. Install roof mounted PV system sized 17 kW. Interconeccted with main service panel. (74) Hyundai HIS-S270 Modules(2) ABB PVI-6000 Inverter(1) ABB PVI-5000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6802	11041-20000-26901	1115 S ALVARADO ST	90006	1	129A201    14	5136018902	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM			PC Approved	12/16/2011 12:00:00 AM	ADDRESS	34.04969	-118.28139	Revisins to 11041-20000-13095	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6803	15041-20000-05276	4141 N LANKERSHIM BLVD	91602	2	165B177   998	2423029034	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.03	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.14519	-118.36295	BUILDING ADDITION. NEW SINGLE STORY STORAGE SPACE. REBUILD FIRE DAMAGED TENANT SPACE. PC FOR POWER AND ENERGY. PER BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6804	16041-10003-05065	2633 E CESAR E CHAVEZ AVE	90033	14	127-5A225  16	5177033029	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.0454	-118.20418	Supplemental PC for changes in lighting to restuarant TI. All changes clouded under delta 13.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6805	15041-10000-37935	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	T-24, THEATER AUDITORIUM ENTRY UPGRADE, SCOPE INCLUDES NEW LIGHTING ON A PORTION OF THE ENTRY WAY AND RECEPTACLES. PC FOR ENERGY ONLY. TOTAL SQ. FT. 192.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6806	14041-20000-14205	6120 N YOLANDA AVE	91335	3	177B121   497	2127016018	MR1-1, P-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.18132	-118.54025	Plan check for Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6807	19041-10000-26964	6520 W MARYLAND DR	90048	5	135B173   478	5510016021	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Issued	08/20/2019 12:00:00 AM	ADDRESS	34.06747	-118.37027	[e-plan]  Install 2 Energy Storage Systems @27KWH & 1 New 200A Load Center & 1 New 125A Load Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6808	16041-10000-03683	606 E VENICE BLVD BLDG. D	90291	11	108B145  1741	4237002007	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.98922	-118.46166	TIon a commercial office Building D. New 800Amp service 120/208. Scope of work inlcudes new lighting and receptacles.  Total area 9,453 sq.ft. PC for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6809	17041-20000-13866	4835 N VAN NUYS BLVD # 200	91403	4	169-5A151 141	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.1588	-118.44891	Plan check for power and energy. Project site is an existing medical office suite. Project scope is a tenant improvement. Total lighting area = 1,974 sq. ft.Note: Building permit has been pulled under 17016-20000-07404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6810	12041-10000-17595	700 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			PC Info Complete	07/27/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	TILT 24 AND 6 CKTS,  FOR B GRILL AT LAX FOR TERMINAL 7. SPACES 7 G.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6811	14041-20000-05438	20305 W AETNA ST	91367	3	177B113   147	2149008008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.17902	-118.57573	pv1 single family dwelling. total system size 4.3 kw ac using microinverter using enphase m215. using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6812	17041-10000-24521	1915 N BRONSON AVE	90068	4	150A191   171	5586014068	C1-1D	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Issued	07/20/2017 12:00:00 AM	ADDRESS	34.10545	-118.31816	PC FOR SERVICE UPGRADE 800A 120/208VSCOPE INCLUDES NEW SERVICE EQUIPMENT INSTALLATION IN ELECTRICAL ROOM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6813	16041-10000-42841	444 S FLOWER ST #3900	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	T-24, PC FOR ENERGY ONLY. TENANT IMPROVMENT TO (E) OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 525 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6814	15041-20004-28938	14749 W VINCENNES ST	91402	6	198B149   175	2650030006	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM			PC Approved	08/07/2018 12:00:00 AM	ADDRESS	34.24038	-118.45553	Plan check for lost set of plans. PV1 roof mouted systen for a single family home . Scope of work: system size: 20KW AC (64) modules, (4) inverters: 20 kw (total), load center: 125 amps.  Plan check only. Permit pulled under 15041-10000-28938	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6815	14041-10000-06325	1423 N ORIOLE DR	90069	4	147B169   711	5560006015	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Expired	05/02/2016 12:00:00 AM	ADDRESS	34.09755	-118.38834	Servcie upgrade only from 800 Amp to 1200 Amp in single Family Dew.  Spa and screen room are permitted under separtae permits 14041-10000-08547 and 14041-10000--07638.  This submittal is only for plan check of upgrading service, no branck circuits are under submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6816	19041-10000-01047	11271 N SAN FERNANDO ROAD	91331	7	210B157   129	2616020028	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			Corrections Issued	01/18/2020 12:00:00 AM	PIN	34.27471648	-118.43164899	PROPOSED CHANGE OF USE FROM WAREHOUSE TO INDOOR NURSERIES (F-1 OCCUPANCY)  AND OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6817	18041-10000-12214	2800 E LUGO ST	90023	14	117A221    25	5169026023	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	11/10/2021 12:00:00 AM		Permit Finaled	01/26/2023 12:00:00 AM	ADDRESS	34.01642	-118.21977	NEW COMMERCIAL BUILDING. PLAN CHECK FOR POWER AND ENERGY.BLDG PERMIT#: 18010-10k-01413	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6818	18041-10000-00998	6724 N ETON AVE	91303	3	180B105    21	2148030037	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	34.19265	-118.59524	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 73375 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6819	15041-10000-15395	707 W WILSHIRE BLVD SUITE 5100	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN SUITE 5100.  TOTAL SQUARE FOOTAGE 6987	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6820	18041-10000-34513	11339 W CAMARILLO ST	91602	2	168B173   428	2353023022	C4-1	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.15778	-118.37855	Plan check for T24 only, Tenant Improvement to existing Starbucks kitchen area with a total area of  370-sq.ft(B# 18016-10000-29192)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6821	12041-10000-29382	17201 W GRESHAM ST	91325	12	195B133   279	2690013006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.2305	-118.50872	PV1 SINGLE STORY ROOF MOUNTED SOLAR INSTALLATION. INTERCONNECTED WITH MAIN SERVICE PANEL. SYSTEM SIZE IS 7.48 KW. THREE STRINGS WITH 34 MODULES AND USING TRANSFORMERLESS INVERTERS [INVERTER: MULTIPLE ||||| PV MODULES: KYOCERA # KD220GX]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6822	12041-10000-10975	610 S SERRANO AVE	90005	10	135B193   920	5503028006	(T)(Q)C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.06307	-118.30639	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT FOR EXISTING CAFE/RESTAURANT. LESS THAN 100 OCCUPANTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6823	13041-10000-29209	964 S BERENDO ST	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.05378	-118.29358	FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY BAPTIST CHURCH AND PRIVATE SCHOOL OVER ONE LEVEL OF SUBTER. PARKING GARAGE. NEW UNDERGRND SERVICE 2500A,480/277, 3-PHASE. TOTAL AREA (UNCONDITION + CONDITIONED) FOR ENERGY IS 229958 SQ FT. NONE METHANE ZONE ON ZIMASBLDG PERMIT UNDER 12010-10002-02799	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6824	18041-10000-29606	120 E 31ST ST	90011	9	118-5A205  39	5120001007	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.0206	-118.27048	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.175KWdc /  4.80KWac.(15)AC MODULES-SUNPOWER SPR-X21-345-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6825	13041-20000-10411	11050 N BAILE AVE	91311	12	210B117   129	2708023010	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.2713	-118.56117	New Ungrounded, rooftop mounted PV System for an existing single family dwelling.  System uses Solaredge DC/DC Converters. DC/DC CONVERTERS ARE CHARGED AS TOTAL SYSTEM KW TRANSFORMATION AS NONDWELLING PWR EQUIP. PER SUPERVISOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6826	10041-10000-20813	924 S WESTWOOD BLVD #615	90024	5	135B153   539	4363019902	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM			PC Approved	10/19/2010 12:00:00 AM	ADDRESS	34.06308	-118.44513	Tenant inprovement in officesplan chk is for title 24 ; permit obtaine don 10041-10000-17730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6827	14041-20000-02598	7466 N LOUISE AVE	91406	6	186B133  1166		R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.20652	-118.50969	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6828	19041-10000-18337	528 W 106TH ST	90044	8	090A201   308	6061024008	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	33.93982	-118.28374	PC FOR PV-1 , SYSTEM INCLUDES 11 MODULES (HANWHA ) W 320 SOLAREDGE OPTIMIZERS AND 1 3000H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6829	15041-10000-23181	1359 W WASHINGTON BLVD	90006	1	126A201   130	5056012018	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	PIN	34.04034655	-118.28556319	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 7768 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6830	17041-10001-02866	13705 W VENTURA BLVD	91423	4	165B157   603	2271018008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM			PC Approved	06/21/2017 12:00:00 AM	ADDRESS	34.14823	-118.43147	PC FOR CHANGES TO APPROVED SET  TO REFLECT CHANGES IN FIXTURES TYPE. FLOOR AND TITLE 24  FORMS REVISED. ADDITIONAL AC UNIT INSTALLED. *********************************************************************Plan check fot Title 24 only in 3 existing space T.I. to restaurant. Total area: 1,900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6831	13041-20000-20520	10118 N SOPHIA AVE	91343	12	204B137   669	2678004012	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.25454	-118.48803	solar syatem single family 16.910kw service upgrade to 225 A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6832	10041-20001-13940	11410-11414 S CENTRAL AVE	90059	15	087A211   162	6070016004	C2-1VL	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Expired	12/07/2012 12:00:00 AM	ADDRESS	33.9306	-118.25406	"Plan check for T-24 Energy (general/emergency) lighting. Permit for additional ckts installed not covered in previous permit. ""COMPLY WITH DEPARTMENT ORDER effective date03/17/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6833	16041-10000-42085	1605 E 1ST ST	90033	14	129A219    77	5173031007	[Q]M1-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.04758	-118.22264	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM WAREHOUSE TO OFFICE & ART STUDIO, AND BREAK-ROOM SPACE. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS AND NEW LIGHTS. TOTAL AFFECTED AREA IS 3574 SQ. FT. B#16016-10000-20937	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6834	17041-10000-14405	10250 W SANTA MONICA BLVD #9170	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	First tenant  Grom Gelateria Ste. 9170, 300sq.ft	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
6835	10041-10000-06239	8500 N BALBOA BLVD	91343	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge			1173.02, 1173.03	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	PIN	34.22443327	-118.49947932	remodel showroom area  for an electronic storeplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6836	16041-10004-23960	2409 N GRIFFITH PARK BLVD	90039	4	148-5A205  38	5432003004	RD2-1VL, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Apartment			11/01/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.10303	-118.27254	Change to approved set by adding exit signs on the floor plan; All changes under delta-2 only.(((PC FOR POWER AND ENERGY. PROPOSED 3 STORY, 13 UNITS,  RESIDENTIAL APARTMENT BUILDING OVER SEMI SUBTERRANEAN PARKING.  SERVICE SIZE 1200 A. 4 TYPICAL UNITS.B # 16010-10000-02240)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6837	14041-20001-06061	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	33.97902	-118.43558	(((expedite fees)))pv2 commercial rooftop. solar modules to be installed on new canopy. total of 60 modules. using 480V interconnection. interconnect to existing 300A service system size 13 kw AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6838	18041-20000-21394	1880 S CENTURY PARK EAST #613	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.06144	-118.41437	PLAN CHECK FOR TITLE 24 ONLY FOR TI -  RMODEL TO REMOVE AND REPLACE NON-BEARING PARTITIONS, RELOCATION OF DOORS. TOTAL AFFECTED AREA = 991 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6839	13041-20000-29370	4614 N MIRADOR PL	91356	3	168B121   470	2176032011	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.15412	-118.54778	PV1 10.92 KW NEGATIVELY GROUNDED SYSTEM. 42 MODULES AND 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6840	13041-10000-05359	4620 N RUBIO AVE	91436	5	168B137   553	2284009034	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.15521	-118.49437	10.5 KW DC solar installation on roof of 1 story house.  {3 transformerless inverters: POWER-ONE PVI-3.6-OUTD-S-US} {42 modules: SUNTECH STP250S-20}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6841	17041-10000-44085	950 W 76TH ST 1-50	90044	8	099B197   208	6020009032	C2-1VL	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	Apartment			12/07/2017 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	03/01/2021 12:00:00 AM	ADDRESS	33.97053	-118.29106	Full plan check for a (3) story 50 unit mix used affordable housing over (1) story parking garage.  B#17010-10000-03985	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6842	16041-20000-20678	8436 W 3RD ST #602	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.07301	-118.37448	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 948 sq. ft.Note: Building application has been generated under 16016-20000-09322	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6843	18041-30000-48935	13028 W SAN VICENTE BLVD	90049	11	129B137   494	4264001006	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.04842	-118.49065	Plan check for Title 24 only. Project site is an tenant space is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 732 sq. ft.Note: Building application has been generated under 18016-30000-41137	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6844	17041-10000-25132	17955 W VENTURA BLVD	91316	5	171B129   191	2162006002	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.16444	-118.52377	Plan check for core and shell building for future dollar tree with existing service adding 3 new panels with no load on all panels. Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6845	14041-10000-32440	4156 S BROADWAY	90037	9	114A203    72	5111018027	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.00787	-118.27813	Energy plan check for a commerical store T.I. in a mini shopping mall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6846	17041-20000-30513	23016 W FRIAR ST	91367	3	177B097    45	2039011035	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.1853	-118.62843	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (29) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6847	17041-20000-40296	15126 W BURTON ST	91402	6	192B145   503	2209006001	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	PIN	34.22031945	-118.46288056	PV1.  Install 3.8 kW AC roof mounted grid tied PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6848	16041-20000-21144	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011065	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	33.98173	-118.4029	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 33,737 sq. ft.Note: Building application has been created under 16016-30000-13757	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6849	16041-20000-22733	5700 W WILSHIRE BLVD 1ST FLOOR	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.06218	-118.35303	RENOVATION OF (2) EXISTING TENANT ELEVATOR LOBBIES ON THE GROUND FLOOR; PLAN CHECK FOR ENERGY. 4486 SQ FTBUILDING PERMIT UNDER 16016-10000-03231	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6850	19041-10000-15340	250 W CENTER WAY PS-2a	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Issued	01/10/2020 12:00:00 AM	ADDRESS	33.94439	-118.40399	(LAX, ASSIGN TO FRANCIS PER APPLICANT REQUEST) PLAN CHECK FOR POWER AND ENERGY FOR TI TO P2A PARKING STRUCTURE AT LAX. SCOPE INCLUDES REPLACEMENT OF ALL LIGHTS, INSTALLATION OF ELECTRICAL VEHICLE CHARGING STATION, CHANGES TO SIGNAGE INSTALATION AND EQUIPMENT. SCOPE ALSO INCLUDES A 1000A 480/277 SWITCHBOARD AND A 75KVA TRANSFORMER. TOTAL AFFECTED AREA IS 299,500 SQ.FT	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
6851	18041-20002-42224	16174 W WOODVALE ROAD	91436	5	165B141   463	2285011025	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.14529	-118.4803	PLAN CHECK ONLY CHANGES TO APPROVED SET, RELOCATION OF PV AND ESS EQUIPMENT.$0 PLAN CHECK FEES DUE TO SB 1222 AND AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6852	12041-10000-28472	10 S CHESTER PL BLDG 5-#207	90007	8	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.03079	-118.27732	TWO CLASSROOMS IN SKILL LAB  CONVERTED TO ONE CLASSROOM-NEW CIRCUITS AND LIGHTING FIXTURES ON THE SECOND FLOORPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6853	11041-20000-07768	10556 W KESWICK ST	91352	2	186B177    32	2466029001	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM			PC Approved	04/18/2011 12:00:00 AM	ADDRESS	34.21037	-118.36166	T-24 ONLY FOR AN EXISTING MANUFACTURE BUILDING.  PERMITS AND PENALTY FEES WILL BE SEPERATE, PLAN CHECK ONLY - OTC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6854	19041-10000-42258	11100 W SANTA MONICA BLVD 10TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTS IN BATHROOMS, EXISTING CIRCUITS AND CONTROLS. TOTAL AFFECTED AREA IS 603 SQFT.B#:19016-10000-30779	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6855	17041-20002-43986	23159 W BIGLER ST	91364	3	171B093   807	2074021017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	34.16076	-118.63125	[12/28/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. ADDITION OF DISCONNECTS, MODULES AND INCREASING INVERTER SIZE]]]]PV1.  Install 10.2 kW roof mounted grid tied PV system.  (34) modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6856	18041-20000-42217	8900 N DE SOTO AVE bldg 112	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.23162	-118.58832	provide EM power to bldg 112 from existing EM distribution board and provide new lighting new controls to existing rooms.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6857	18041-10002-43449	17915 W ERWIN ST	91316	5	177B129    15	2123022022	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.184	-118.52364	SUPPLEMENTAL FOR FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED 10KVA PV SYSTEM REMOTELLY MOUNTED ON GARAGE CONSISTING OF 1 CENTRAL INVERTER(10000H-US) WITH 23 MODULES USING P320 OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6858	19041-20000-34199	905 E 2ND ST STE 110	90012	14	129A215   387	5163003063	(T)(Q)C2-2D	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04729	-118.23499	Plan check for Title 24 only in existing space Dog Day Care Tenant Improvement. Total area: 1435 sq ft. B#19016-10000-19883	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6859	19041-10000-21613	18200 W RINALDI PL	91326	12	213B125   609	2715033049	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.27692	-118.52901	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6860	13041-10001-17734	4180 N VERDUGO VIEW DR	90065	1	154-5A219 213	5472010028	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.11787	-118.22289	CHANGE OF MODULES FROM REC 250 PE TO ET SOLAR ET-P660255W.(((PV1 2.59KW MICROINV 2STORY. STD. ROOFMOUNT.[ 12MICRO INVERTER: : ENPHASE ENERGY M215-60-2LL-S22] [MODULE:  {REC 250 PE} )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6861	14041-20000-13358	9121 N OAKDALE AVE	91311	12	198B113   153	2761001068	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.23622	-118.56725	PLAN CHECK FOR ENERGY ONLY T-24.  OFFICE TI RELOCATING LIGHTING FIXTURES IN AN EXISTING CONFERENCE ROOM COMMERCIAL ONE STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6862	19041-10000-18186	445 S FIGUEROA ST 1900A	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	T-24 plan check for a Tenant improvement work to a partial area of an (E) office. Scope includes new lighting, controls and receptacles. Total affected area is 1880 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6863	19041-10001-47156	12241 W MOORPARK ST APT #1	91604	2	165B165  1313	2364003082	[Q]R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM			PC Approved	01/15/2020 12:00:00 AM	ADDRESS	34.15056	-118.4001	NEW ROOF MOUNTED 3.35KW PV SYSTEM WITH 10  @ (335W) PV PANELS WITH OPTIMIZER AND ONE 3.8KW CENTERAL INVERTER ON AN APARTMENT BUILDING - APT#1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6864	15041-10001-30657	800 E 4TH ST	90013	14	127-5A215 253	5163025001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.04322	-118.23729	PC FOR CHANGES TO APPROVED SET OF PLANS. RECHECKING UPDATED HOME RUN DESIGNATIONS DUE TO 2 NEW PANELS. REVISED SINGLE LINE TO SHOW SINGLE UTILITY METERING POINT NO OTHER CHANGES. PERMIT TO BE ISSUED FOR THE NEW PANELS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6865	15041-20000-27842	23211 W INGOMAR ST	91304	12	189B093   587	2020022025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.21204	-118.63267	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (33) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6866	19041-30000-06429	5608 W LA MIRADA AVE	90038	13	144B193   287	5536004003	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			02/21/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Issued	03/26/2019 12:00:00 AM	ADDRESS	34.09365	-118.3112	Plan check for power and energy. Project site is a 5-story, 13-unit apartment building. Work includes an 800-amp service and a total lighting area of 14,363 sq. ft.Note: Building application has been generated under 16010-20000-05427	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6867	14041-10000-09788	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	tI PORTION OF AN  EXISTING RETAIL STORE. TITLE 24 AND EMERGENCY LIGHTING. THIS IS PART OF BEVERLY CENTER. BUG EYES OKAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6868	12041-10000-16520	645 S LA BREA AVE	90036	4	135B181   770	5508007022	C2-1	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.06359	-118.34421	New retail space in an Existing Commercial Building.  New 800Amp Service.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6869	17041-20001-32187	17142 W OTSEGO ST	91316	5	171B133   493	2258011010	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/28/2017 12:00:00 AM	ADDRESS	34.16356	-118.50716	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.(64) 320W AC modules. 20.48kW ungrounded system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6870	17041-10000-19756	15303 W SHERMAN WAY	91406	6	183B145    59	2222027201	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.20139	-118.4666	REPLACE  LIGHTING FIXTURES TO LED TYPE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6871	18041-10000-09882	1816 N VERMONT AVE	90027	4	150B197  1082	5590020002	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Issued	03/19/2018 12:00:00 AM	ADDRESS	34.10411	-118.29162	PC for T24 only for change of use from retail to restuarant. Installing lights, receptacles and equipment. B: 16016-10000-31194b:CHANGE OF USE FROM RETAIL TO RESTAURANT. NO CHANGE IN PARKING PER VERMONT SPECIFIC PLAN. FULL COMPLIANCE WITH 2017 LABC APPENDIX A1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6872	16041-10002-27380	877 S FRANCISCO ST	90017	14	129A207   122	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.04791	-118.26383	Delta F Changes to permitted set of plans: new feeder from SWBD SS-R2-B1 to ATS-LS-R2 which supplies new dist board PNL-LS-EHB1. New dist board ssupplies pnl ls-el2 through new xfmr LS-ETB1-2 ;New ciruits to existing panel boards' CHANGES ARE CLOUDED AND IDENTIFIED AS delta 7. (((((((PLAN CHECK FOR POWER AND ENERGY FOR BLD R2, A  HIGH RISE MIX USE, RETAIL, PARKING, AND RESIDENTIAL BUILDINGS. R-2, RESIDENTIAL  NEW TENANT SPACES FROM FLOORS 5 THROUGH 42 INCLUDING 514 NEW PANELS(14 TYP UNITS) AND ONE 50 HP POWER MOTOR CONNECTED TO EXISTING. METER SWITCHGEAR UPGRADE TO 2000 AMP SERVICES.ORIGINAL CORE/SHELL APPLICATION COVERS BUILDING R2 AND R3.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6873	15041-20000-11637	3860 S CRENSHAW BLVD Suite 229	90008	10	117B185   821	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM			PC Info Complete	04/28/2015 12:00:00 AM	ADDRESS	34.01577	-118.33473	Plan check for dental office(T.I.) Total area: 709 sq ft. power and energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6874	17041-10000-04468	415 N HAWAIIAN AVE	90744	15	027B201   421	7417005901	[Q]RD2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM				Installation of a new fire alarm system io building 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6875	13041-10003-26820	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			11/06/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.39042	DELTA 3 CHANES TO PERMITTED SET OF PLANSPLAN CHK ONLYNew 218-unit apartment building at Howard Hughes Center.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6876	13041-10000-11613	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022	A1-1-H, A2-1, PF-1XL, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.08694	-118.47588	Conversion of reading room in the Getty Research Institute Building Level PL Gallery to a gallery space.  Work consists of lighting modification and addition of power raceways.  Title 24 plan check only.  Permit to be issued at the Electrical Plan Check Counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6877	17041-10000-24520	1803 S PACIFIC AVE	90731	15	012B197   813	7462007030	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2972.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.72768	-118.28817	Plan check for Title 24 only in existing space, remove metal halide fixtures outdoor and replace with new LED fixtures. Total area: 6600 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6878	18041-10000-28074	1638 W TEMPLE ST	90026	13	136-5A207 177	5159022010	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.06824	-118.26225	CHANGE OF USE FROM EXISTING RETAIL TO COFFEE SHOPPLAN CHECK IS FOR TITLE 24 energy only. total affected area 650 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6879	18041-10000-20135	913 S OCEAN FRONT WALK	90291	11	108A143   225	4286027013	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	33.99032	-118.47653	Change of use from Retail to Take-out Restaurant and interior tenant improvement, no seating.PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6880	19041-10000-32977	123 S HEWITT ST	90012	14	129A215   139	5163002026	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Issued	08/22/2019 12:00:00 AM	ADDRESS	34.04798	-118.23627	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6881	18041-10001-32496	4835 S SEPULVEDA BLVD	90230	11	111B165   200	4215031037	C2-1, R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM			PC Approved	07/25/2019 12:00:00 AM	ADDRESS	34.00052	-118.40294	PC ONLY. DELTA 7 & 8 CHANGES TO AN APPROVED SET. ADDING AN ACCESSIBLE RESTROOM TO THE PLAY ROOM TO COMPLY WITH ADA REQUIREMENTS. UPDATES TO THE FLOOR PLANS AND T-24 FORMS.  B# 18016-20002-27448Original Plan check: FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW MC DONALD - NEW SERVICE AT 1000A WITH TOTAL AFFECTED AREA = 4956 SF == BLDG PERMIT: 18016-10000-27448	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6882	18041-10000-38217	750 S LAMAR ST INBOUND TR-UCK CANOPY	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (H) INBOUND TRUCK CANOPY8 OF 10BUILDING PERMIT 13010-10000-01027	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6883	16041-20000-09380	8633 N WOODLEY AVE	91343	12	195B137   956	2689024022	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	34.22755	-118.48551	Plan check for energy only. TI to existing retail space to restaurant (Wing Stop). New lighting (incl. emergency). 1,941sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6884	15041-20002-18506	19207 W VICTORY BLVD #2	91335	3	180B121   522	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	34.18674	-118.55154	Expedite per applicant request[[[[Plan check for PV roof mounted system. System size: 4.0kW with 10 modules and 1 inverter (4.0kW) connected to 125A unit panel and connected to Meter Bank(600A)]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6885	13041-10004-31237	1038-1048 S MARIPOSA AVE	90006	1	129B197   387	5078016016	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			04/29/2016 12:00:00 AM			PC Approved	04/29/2016 12:00:00 AM	ADDRESS	34.05151	-118.2988	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 5 REVISIONS. REVISION INCLUDES REVERT BACK TO PANEL HPB. LIGHTING CIRCUITS CONNECT TO PANEL HPB. FLOOR PLAN AND SINGLE LINE UIPDATED. CHECKING NEW FAULT CURRENT RATINGS AND CIRCUIT LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6886	12041-10001-29382			12	195B133   279	2690013006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM			PC Approved	05/20/2013 12:00:00 AM	PIN	34.2308767	-118.50886449	PLAN CHECK ONLY SUPPLEMENTAL TO PLAN CHECK NUMBER 12041-10000-29382. PERMIT UNDER ORIGINAL APPLICATION. TIE IN OF EXISITING DC SYSTEM TO LOAD CENTER (PERMIT NUMBER 07041-20000-24621) EXISTING SUNNY BOY 6000 INVERTER. DISCONNECT A MINIMUM OF 17 FEET DISTANCE FOR AVAILABLE FAULT CURRENT < 10000. SPLIT BUSS BREAKER REDUCED TO 150, CALCS INCLUDED, ELECTRIC COOKING IS NOT USED.************************************************************PV1 SINGLE STORY ROOF MOUNTED SOLAR INSTALLATION. INTERCONNECTED WITH MAIN SERVICE PANEL. SYSTEM SIZE IS 7.48 KW. THREE STRINGS WITH 34 MODULES AND USING TRANSFORMERLESS INVERTERS [INVERTER: MULTIPLE ||||| PV MODULES: KYOCERA # KD220GX]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6887	16041-20000-24903	17808 W CHATSWORTH ST	91344	12	207B129   447	2733005010	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM			Permit Closed	03/18/2017 12:00:00 AM	ADDRESS	34.26466	-118.52195	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1020.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6888	16041-20001-01991	527 N WESTMORELAND AVE	90004	13	141B197   890	5539031008	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.08071	-118.28813	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 10kW with 36 modules and 1 inverter(10kW)}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6889	18041-20001-45200	6653 W MARYLAND DR	90048	5	135B173   389	5510014011	R1-1-O-RFA	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.06795	-118.37267	Expedite per applicant requestPlan check for PV roof mounted system and energy storage system, PV system size: 12.35kW DC, 11.5kW AC with 20 PV Modules, 1 inverter(7.6kW) and 2 LG Chem Battery(9.8kW), 2 sup-panel for battery and critical loads	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6890	19041-10000-52874	14724 W VENTURA BLVD Lobby	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Issued	01/16/2020 12:00:00 AM	ADDRESS	34.15162	-118.45395	Installing new lights in the common area of the lobby of a High Rise Bldg. T-24 Energy Only.Affected area: 6,543 SFT.Bldg Permit: 19016-30000-40536	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6891	18041-10000-48940	1817 N SICHEL ST	90031	1	135A223   148	5210008022	R3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Info Complete	08/09/2019 12:00:00 AM	ADDRESS	34.0644	-118.21294	PLAN CHECK FOR POWER AND ENERGY FOR - NEW CONSTRUCTION OF 5 STORY ABOVE SUB-GARAGE, 18 UNITS   T.O.C. - NEW SERVICE RATED AT 1000A 120/240V WITH ASSOCIATED EQUIPMENT AND A TOTAL OF 11000SF FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6892	18041-20000-31029	12070 W VENTURA BLVD	91604	2	162B165   141	2369015019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.14342	-118.39462	Plan check for Title 24 only outdoor lighting parking lot. Total area: 35,480 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6893	18041-10000-20849	2100 W 3RD ST Suite 190	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.06281	-118.2731	PC FOR OFFICE TI  IN (E) OFFICE. SCOPE INCLUDES NEW CIRCUITS, LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1045 SQ.FT. B#18016-10000-13861	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6894	19041-20000-03664	9908 W KIP DR	90210	5	147B153    94	4356006001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.10126	-118.43313	225A main panel upgrade, 200A load center, and 13.5 kWh energy storage system.  (E) 7.17 kW PV system on site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6895	12041-10000-06466	100 W WORLD WAY Terminal 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	PIN	33.94684048	-118.40128468	Change of lighting to an existing office space at Terminal 1 in LAX, No suite per applicant.  Load per applicant is 241A.  PLAN CHECK ONLY for Energy with Emergency lighting.  NO CLASSIFIED/HAZARDOUS AREAS within scope of work, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6896	17041-10000-19749	2231 S WESTERN AVE	90018	10	123B193   238	5058009041	C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.03519	-118.30929	REPLACE  LIGHTING FIXTURES TO LED TYPE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6897	16041-10000-31351	7809 N RANCHITO AVE	91402	6	189B157   773	2214015004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Expired	10/18/2018 12:00:00 AM	ADDRESS	34.21223	-118.43193	PC FOR ROOF-MOUNTED PV SYSTEM. 3.8KW AC USING TOTAL OF 9 MODULES. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6898	19041-20000-36650	4700 N TOPEKA DR	91356	3	168B121   355	2176030038	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Expired	07/12/2021 12:00:00 AM	ADDRESS	34.1554	-118.54647	PV1.  Install 11.34 kW roof mounted grid tied PV system.  (36) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6899	19041-10000-15549	2902 N HYPERION AVE	90027	4	151-5A205 120	5434027026	C4-1D	Central	Hollywood	Silver Lake		1882.01	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	34.10939	-118.27099	ALTERATION/REPAIR TO EXISTING 1-STORY COMMERCIAL BUILDING.  WATER DAMAGE REPAIR TO EXISTING ROOF FRAMING. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BILDING PERMIT: 19016-30000-06832	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6900	18041-10000-39402	13885 W SAYRE ST	91342	7	222B153    24	2509020004	R3-1-CPIO	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.30843	-118.43596	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6901	14041-20000-20250	8956 W WONDERLAND PARK AVE	90046	4	153B169   501	5564019053	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM			Plans on Hold	07/29/2014 12:00:00 AM	ADDRESS	34.11469	-118.39031	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 5.2 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS.Zoning clearance obtained under plan check application 14041-20000-20204	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6902	16041-20001-08656	13930 W JUDD ST	91331	7	204B153   109	2618018019	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM			Reviewed by Supervisor	03/30/2016 12:00:00 AM	ADDRESS	34.25936	-118.43654	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3kW. Ungrounded system. One 300W power optimizer per module.(7) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6903	17041-20000-33842	6108 N LAURELGROVE AVE	91606	2	177B165   480	2333006061	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.18149	-118.40074	Plan check for the addition of a battery back-up system (Tesla PowerWall) to an existing PV1 roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6904	15041-20000-24612	19561 W LORNE ST	91335	3	189B117   142	2105003020	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.21689	-118.5602	Plan check for PV roof mounted system. System size: 5.0kW with 15 moduels and 1 inverter(5.0kW). Standard Plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6905	13041-20000-31380	380 WORLD WAY T56	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	SPACE T56 2 SIGNS. INTERNALLY ILLUMIATED WITH LED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6906	16041-20001-35327	13836 W HAYNES ST	91401	2	180B153   719	2238016006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/18/2016 12:00:00 AM	ADDRESS	34.18929	-118.43469	EXPEDITE PER APPLICANT REQUESTPlan check for installation of pv system on SFD, roof-mounted. Interconnect with 200A MSP. 3kW ungrounded system. (16) 255W pv modules. Each module has a 300W power optimizer.There is an existing 3kW ungrounded system on the building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6907	17041-10000-03290	5400 S BROADWAY	90037	9	108B201   598	5101032030	C2-1VL	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	33.9931	-118.2781	Plan check for PV roof mounted system. System size: 7.6kW with 27 modules and 1 inverter(7.6kW).Building application has been submitted, clearance is under building permit. 17016-10000-01810	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6908	17041-10000-05634	5838-5848 1/2 W 88TH ST BLDG 11	90045	11	096B169   870	4125009001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Issued	04/18/2017 12:00:00 AM	ADDRESS	33.9566	-118.38442	PC FOR POWER ONLY FOR A NEW 600A 120/208 1 PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD, AND NEW SUBPANELS. SERVICE IS FOR AN EXISTING 12 UNIT TENANT SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6909	17041-10000-18111	15911 W ARMINTA ST	91406	6	189B141   146	2206007036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.21399	-118.47971	REMOVE EXISTING HID FIXTURES AMD REPLACE WITH NEW HID FIXTURES - TOTAL OF 6 FIXTURES. SQ. FT. 3600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6910	10041-10000-08565	6333 W 3RD ST E-12	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	ADDRESS	34.07157	-118.36014	TI in an existing shoes store. Plan check for Energy and T24. (Permit # 10041-30000-08053)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6911	17041-20000-21070	15260 W VENTURA BLVD # 1050	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check for energy only. TI to office suite 1050 in high rise building. New lighting (incl. emergency) - 2,028sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6912	13041-10000-35293	7007 W IMPERIAL HWY 100 & 200	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	33.93185	-118.41447	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX. GOING FROM WAREHOUSE TO OFFICE+WAREHOUSE.BUILDING PERMIT # 13016-10000-25741	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6913	15041-20001-42064	4910 N TOPEKA DR	91356	3	168B121   100	2176029031	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.15907	-118.54644	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (44) modules, (44) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6914	16041-20001-10814	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.07457	-118.37864	Revisions to approved plans.  Change in supply of inverter backing up MRI machine.  Full plan check for NEC requirements per inspector - MRI room is a general patient care area per applicant.  Additional permit fees paid for MRI equipment and UPS.  (((TENANT IMPROVEMENT OF EXISTING MEDICAL OFFICESPACE; NEW MR  EQUIPMENT AND CLEAN ROOM. PC FOR ENERGY ONLY (PER F.Y) TOTAL AREA: 593 SQ.FT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6915	13041-10000-36312	1110 S CROCKER ST	90021	14	124-5A211 287	5132010059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.0336	-118.25109	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 700 SQ FT. REPLACING TOTAL OF 4 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6916	15041-20002-37643	1301 N MONACO DR	90272	11	129B133    47	4425014013	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.05346	-118.50125	Changes on an approved set, adding 2 modules, total module is 48. No additional fees per California State Bill 1222. Permit under 15041-20000-37643****PV1, roof mounted solar panel, 13.8kW DC(46) modules: LG ELECTRONICS LG300N1K-G4, 300W(46) micronverters: ENPHASE M250-60-2LL-S2X	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6917	16041-20000-34259	10519 W RIVERSIDE DR	91602	4	165B177    80	2424001004	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			09/27/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.15236	-118.35994	Plan check for power only. New 600A service for existing 12 unit apartment buiding.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6918	11041-10000-24439	2614 W 7TH ST	90057	1	133-5A201 297	5141013028	C2-2, R4-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM			PC Approved	11/23/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	CHANGES TO PERMITTED SET OF PLANS : CIRCUITS IN  PANEL OP HAVE VA LOADS INCREASED/DECREASED; PANEL OP HAVE BEEN PERMITTED ON ORIGINAL; CHANGES IN THELAYOUT OF THE OFFICE SPACE; LIGHTING SYSTEM WAS CHANGED<<CORE & SHELL APPROVED UNDER:  09041-10002-23033>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6919	15041-20001-11922	5698 S GOLDENEYE CT unit 1	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	33.9792	-118.41068	Expedite per applicante request******Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL APPLY TO UNIT # 2 AND #3 OF ADDRESS 5698 GOLDENEYE CORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6920	11041-10000-15239	210 N AVENUE 21	90031	1	139-5A221   8	5447012018	M2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.07715	-118.22138	Existing office space.  Converting open offices into 5 private offices.  They are relocating lighting fixtures and relocating 4 receptacles and installing 10 new switches using existing branch circuits.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6921	10041-10000-04813	2240 W WASHINGTON BLVD Suite #1-Suite #5	90018	10	126B193   951	5073030044	[Q]C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM			PC Info Complete	03/22/2010 12:00:00 AM	ADDRESS	34.03973	-118.31039	T.I. for existing building.  Install general and emergency lighting.  Plan check for title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6922	13041-10000-02644	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	NEW FIRE ALARM SPRINKLER MONITORING SYSTEMSYSTEM FOR AN OFFICE SPACE, B OCCUPANCY.   5 STORY BUILDING, 80,019 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6923	13041-10000-14362	3651 S TROUSDALE PKWY Rm 360	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.01922	-118.28617	plan chk to verify that luminaires in rm 360 complies with title 24 after been removed and cleaned and put back in place	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6924	18041-10001-22058	10900 W WILSHIRE BLVD STE 300	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Info Complete	08/16/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	Replacing Lost Plans. Plan Check Only. Permit was obtained under 18041-10000-22058PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR  819 SQ FT. UROGEN PHARMA. SUITE 300.BUILDING PERMIT # 18016-10000-10911	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6925	11041-10000-06514	12842 W VENTURA BLVD	91604	2	165B161  1046	2384008027	(Q)P-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.14484	-118.4131	INTERIOR TENANTS IMPROVEMENT, NEW GREASE INTERCEPTOR, RELOCATE OF FRONT ENTRANCE, NEW PHARMACY CURTAIN WALL & GRILLE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6926	15041-20000-31594	12056 N ADELPHIA AVE	91340	7	216B161   105	2514005038	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.28948	-118.41235	PV1Install a roof mounted solar array on a SFD. Interconnect with a 100A MSP.Ungrounded system. Using 300W power optimizers (1 per module). (18) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6927	17041-20001-45509	11645 W WILSHIRE BLVD Ste 600	90025	11	129B145   489	4265001036	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.05013	-118.46034	4/18/2018CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 1.  CHANGES INCLUDE NEW PANEL 6EL AND TRANSFER EXISTING CIRCUITS. (((Additional distribution for equipment branch for eye clinic facility in existing commercial highrise building.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6928	11041-10000-04023	700 S FLOWER ST 21 ST FLR	90017	10, 9	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.04835	-118.25882	T.I.  21ST FLOOR.  RELOCATING LIGHTS FOR AN OFFICE.  ADDING 14 NEW CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6929	15041-10000-01934	12457 W OSPREY LANE 1-3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	33.97937	-118.41024	Installation of fire alarm system in new 3 unit apartment building.  50 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6930	18041-20001-07420	649 N RADCLIFFE AVE	90272	11	126B125   441	4412014035	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM			PC Approved	04/25/2019 12:00:00 AM	ADDRESS	34.04238	-118.5309	Revisions to approved set of plans.  Change of powerwall subpanel from 125A to 60A bus rating.$0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consists of (15) AC PV modules, (3) load centers, and (2) Tesla PowerWalls.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6931	10041-10000-23587	123 S ALVARADO ST	90057	13	135A205    14	5154008010	C2-1	Central	Westlake		YES	2085.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.06615	-118.27088	TI for a clinic. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6932	19041-20000-33076	3918 N SCADLOCK LANE	91403	4	163-5A145 102	2281015011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.14194	-118.46874	INSTALL 2 NEW TESLA ENERGY STORAGE BATTERIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6933	18041-10000-42765	3061 S SAWTELLE BLVD	90066	11	120B157  1126	4250026036		West Los Angeles				2716.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.02552	-118.43114	TITLE 24 PLAN CHECK WITH 2900 SQFT OUTDOOR AND INDOOR TO EXCITING SPACE SCOPE OF WORK INCLUDES NEW PANELS AND LIGHTING EQUIPMENTS. REGULAR PLAN CHECK PER CUSTOMER REQUEST.BL# 18016-10000-35738	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6934	13041-10010-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	"06/16/16Changes to an approved set of plans. All changes are made under delta 37. Changes include relocating the elevator pit light circuit from panel ""HPB"" to the ""EM"" panel.  note: permit is pulled under PCIS#13041-10000-11192(((((04/13/16Changes to an approved set of plans, note changes on delta 35. Changes include the addition of 3 security gate circuits, change fuse to a type L and addition of a receptacle. (((03/29/16Changes to an approved set of plans, Note changes on delta 34. Changes include the removal of light fixture and addition of a smoke guard door circuit. )))(((10/18/2015Changes to an approved set of plans. Changes are cluded on delta 28. Changes include the relocation of the inverter battery cabinet and adding block splices from MSB to RA-2. PC only.  )))(((REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  )))((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6935	16041-10000-02246	10366 N HADDON AVE	91331	7	204B157   174	2620016018	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.25874	-118.42606	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2KW INTERCONNECTED WITH MSP.(41) HYUNDAI 260 MODULES(41) ENPHASE 250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6936	18041-10000-12848	3650 E OLYMPIC BLVD	90023	14	118-5A227 227	5191024011	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.01861	-118.1992	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6937	19041-10000-53450	10901 W SANTA MONICA BLVD	90025	5	129B153   517	4324028019	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.0496	-118.43843	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6938	14041-10000-23457	21820 W BURBANK BLVD	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.17228	-118.6032	PHASE 2  :adding new strings/moules and inverter to existing  PV2 ROOF MOUNTED SOLAR SYSTEM. UPSIZING CONDUCTORS CONDUITS (IF NECESSARY) TO ACCOMODATE NEW SYTEMPERMIT IS IN ACCORDANCE WITH SENATE BILL 1222PHASE 1: E13LA03534	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6939	12041-20000-05495	800 W WILSHIRE BLVD #1320	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2012 12:00:00 AM			PC Approved	03/09/2012 12:00:00 AM	ADDRESS	34.0493	-118.25841	office t.i.Energy, emergencyLife/ Fire safety is existing to remainexist. permit 12041-90000-04309	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6940	16041-30002-06446	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	34.04337	-118.23442	05-04-2017 Changes to an approved set of plan. Changes include add exit signs, changes has been clouded as delta 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6941	18041-10000-03921	1602 W 25TH ST	90732	15	009B193     3	7562017017	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.72319	-118.31296	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6942	13041-10000-32638	601 WORLD WAY parking	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	PIN	33.94463112	-118.38247895	plan check for T24 only. PARKING GARAGE ELEVATOR AND LIGHTING UPGRADE FOR LAX . TOTAL AREA IN SCOPE OF WORK IS TO BE 297952 SQ FT AREA. 3 TOTAL FLOORS. EMERGENCY LIGHTING IN SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6943	19041-20000-04229	1915 N HYPERION AVE	90027	4	147A203   184	5430013021	C1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.0977	-118.27553	Change of use from SFD to commercial office.  Plan check for energy. Plan check only, Electrical Permit covered permit number: 16041-10001-33814 and 16041-10000-33814	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6944	18041-20000-00840	19130 W CHARLES ST	91356	3	168B121   226	2176031008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Issued	01/23/2018 12:00:00 AM	ADDRESS	34.15733	-118.55007	pv1install roof mounted pv system sized 7.6kw interconnected with msp with battery back up.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6945	19041-10000-36292	2823 E 11TH ST	90023	14	120A221   134	5170026002	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.02228	-118.2173	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6946	14041-10000-17315	1375 W ADAMS BLVD A-C	90007	8	123B197   881	5055004026	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.03295	-118.29107	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BASKIN ROBBINS.  PREVIOUSLY A PIZZA PLACE. NEWLY CONNECTED LOAD <400 AMPS. 1516 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6947	17041-20000-02411	12862 W FILMORE ST	91331	7	213B161   865	2533029075	(T)(Q)R2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Issued	02/22/2017 12:00:00 AM	ADDRESS	34.27778	-118.41308	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.Note: This is (1) unit of a duplex. Both units will have a PV system installed. Other unit is under 17041-20000-02410.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6948	18041-10000-13601	5919 S METTLER ST	90003	9	105B205   181	6006031025	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	33.98691	-118.26648	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM 6.6KVA SYSTEM CONSISTING CENTRAL INVERTER(SOLIVA6.6) WITH 25 MODULES(TSM-305DD05A) AND RAPID SHUTDOWN DEVICES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6949	10041-20000-05930	11546 W SHERMAN WAY	91605	6	183B169   691	2320001028	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.20097	-118.38407	PLAN CHECK POWER AND ENERGY FOR NEW 1-STORY FAST FOOD RESTAURANT (BURGER KING) WITH 600A SERVICE .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6950	19041-10000-37778	966 S KENMORE AVE	90006	10	129B197    49	5078005026	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Apartment			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	10/14/2020 12:00:00 AM	ADDRESS	34.05364	-118.29671	New Fire warning system for a new apartment building.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6951	16041-20000-15745	5242 W ADAMS BLVD	90016	10	123B177  1006	5043004036	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.03227	-118.35703	Plan check for new 3 story office building. Service size: 1,200A. Total area: 14,381 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6952	17041-10000-16969	6382 S ARIZONA CIR	90045	11	105B165   712	4110014005	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Issued	06/22/2017 12:00:00 AM	ADDRESS	33.97972	-118.39775	PC FOR NEW 800 DISTRIBUTION TO BE UPGRADED. UPS SYSTEM AND DATA RACKS. NO OTHER INTERIOR TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6953	10041-20000-03393	440 N HOOVER ST	90026	13	141A201   357	5401010023	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	Apartment			03/16/2010 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	PIN	34.07888301	-118.28416202	PLAN CHECK POWER AND ENERGY FOR NEW 2 STORY TRANSITIONAL LIVING FACILITY WITH SUBTERRANEAN PARKING.  MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6954	15041-20001-07437	12914 W WINGO ST	91331	7	201B161   368	2624010017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.24934	-118.414	upplemental application for expedite fees.Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6955	16041-20000-24628	10730 N MEMORY PARK AVE UNIT A	91345	7	207B145   239	2649003028	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.26537	-118.46322	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED TO MSP FOR UNIT A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6956	19041-30000-42380	12005 W JEFFERSON BLVD	90230	11	105B165   483	4220008800	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM			Reviewed by Supervisor	12/09/2019 12:00:00 AM	ADDRESS	33.9838	-118.40554	Full plan check for NEW electric meter for Gas copmpany.*********REMOVE AND RECOMPACT AT PROPOSED FENCE WALLS (UNDER 18020-20000-01414) 4' DEEP BY 6' IN WIDTH FOR A DISTANCE OF 120' ALONG JEFERSON BLVD.**********	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6957	16041-20000-04687	2280 W MOSS AVE	90065	1	151-5A217 311	5462012024	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM			Reviewed by Supervisor	02/17/2016 12:00:00 AM	ADDRESS	34.10882	-118.23031	Installation of (N) 4 kW AC ground-mounted photovoltaic system.  (1) SMA SunnyBoy SB4000US-12 with (12) SolarWorld PLUS SW-285 modules with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6958	12041-20000-28138	14508 W NORDHOFF ST	91402	7	198B149   582	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.23519	-118.4484	Plan check for energy and emergency lighting. Wingstop. 1570sqft.CHG OF USE FROM RETAIL TO RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6959	17041-20000-28352	11365 W VENTURA BLVD	91604	2	162B173   448	2366036025	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Info Complete	08/31/2017 12:00:00 AM	ADDRESS	34.14027	-118.37796	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6960	13041-20000-24621	17814 W ARVIDA DR PV-1	91344	12	219B129   276	2601050029	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM			PC Approved	09/09/2013 12:00:00 AM	ADDRESS	34.29823	-118.52169	"Modification to previously approved plans on #13041-20000-16539 to change mounting height of modules to be 18"" only.  Plan Check Only.<<<<PV-1. Two inverters one 5kW and one 6kW inverter. Ground mounted, transformerless system.>>>"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6961	16041-10000-40664	5230 N VAN NUYS BLVD	91401	4	172-5A151 205	2248013009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.16582	-118.44847	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6962	15041-20000-17841	14677 W TUPPER ST	91402	6	198B149   271	2650028013	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.23917	-118.45307	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (29) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6963	17041-10000-35003	10307 S CENTRAL AVE	90002	8	090B209  1607	6051009031	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	33.943	-118.25436	PC for T24 only for outdoor lighting. Replacing HID fixtures and replacing with new LEDfixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6964	13041-10001-27125	2130 N PRINCETON AVE	90026	13	144A211   119	5420036016	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.0899	-118.24872	][][EXPEDITED PER APPLICANT REQUEST ][][][PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH  MAIN; WORK DONE ON A non-STANDARD PLAN WITH POWER OPTIMIZERS. SYSTEM SIZE IS 2.96KW DC WITH (13) MODULES: kyocera #kd220gx-lfbs(1)SOLAREDGE #SE3000A-US(13)SOLAREDGE #OP250-LV-MC4SM-2NA-Z	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6965	19041-20000-36221	844 S BROADWAY	90014	14	127-5A209 204	5144016060	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.04265	-118.25551	P.C FOR OUTDOOR LIGHTING TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6966	15041-20000-28429	955 E 31ST ST	90011	9	117A209   115	5114022012	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			PC Approved	08/28/2015 12:00:00 AM	ADDRESS	34.01537	-118.25814	Plan check for Title 24 only. PLANCHECK ONLY DUE TO LOST PLANS.  Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,410 sq. ft. permit under 15041-20000-20378.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6967	13041-10000-03163	421 N HENRY FORD AVE	90744	15	030B213   392	7440001***	M3, M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	33.77533	-118.24134	PLAN CHECK FOR POWER. NEW TRANSFORMERS, EQUIPMENT, PANEL BOARDS INCLUDING OVERHEAD TRANSMISSION LINE. MEDIUM VOLTAGE INSTALLATION. LOCATION IN CLASSIFIED AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6968	18041-10000-06103	19191 S VERMONT AVE #645	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR TITLE 24 ENERGY ONLY. TENANT IMPROVEMENT TO (E) OFFICE SPACE (HIGHRISE) SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT, RECEPTACLES, AND LIGHTS. TOTAL AFFECTED AREA 2934 SQ FT BUILDING#18016-20000-03481	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6969	18041-10000-40786	777 S FIGUEROA ST	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.04828	-118.26116	REPLACING AN EXISTING FIRE ALARM SYSTEM WITH A NEW ONE, WITH 2,345 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6970	17041-10000-16219	5240 E ALHAMBRA AVE	90032	14	138A235    21	5217019006	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.07431	-118.17124	PC FOR 600A SERVICE UPGRADE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
6971	11041-10000-22518	6911 S CENTINELA AVE	90045	11	105B165   930	4211011061	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM			PC Approved	03/23/2012 12:00:00 AM	ADDRESS	33.98353	-118.40077	T-24 lighting plan check for restroom building.  Interior and exterior lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6972	14041-20002-13786	20630 W NORDHOFF ST	91311	3	195B109    49	2780001039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM			PC Approved	08/28/2014 12:00:00 AM	ADDRESS	34.23282	-118.58205	Field revisions to approved set.  Change in quantity of lighting fixtures in high and low-bay warehouse.  (((New distribution equipment and machinery in (E) manufacturing building.  Install some subpanels, branch circuits, and lighting.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6973	11041-20000-19153	7701 N DENSMORE AVE	91406	11, 6	189B141   270	2206010006	M1-1	South Valley, West Los Angeles	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00, 2677.00	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	09/09/2011 12:00:00 AM	ADDRESS	34.2105	-118.47727	T24 ENERGY FOR EXISTING WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6974	18041-10000-19219	9857 N MASON AVE	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.24955	-118.58012	TI IN AN EXISTING STARBUCKS COFFEE. INSTALL LIGHTS, PANELS & CIRCUTS.PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6975	15041-20001-31730	7033 N HAZELTINE AVE	91405	6	183B153   470	2217015005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.1985	-118.44016	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6976	18041-20000-44048	5158 N CALVIN AVE	91356	3	171B117   265	2163007023	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	02/23/2019 12:00:00 AM	ADDRESS	34.16547	-118.5551	Plan check for a PV1 roof-mounted PV system. System size is 15.6 kWdc/14.4 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (48) modules.$34.49 permit fee due to State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6977	15041-20001-43222	7407 N LUBAO AVE	91306	3	186B113   565	2115005002	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.20498	-118.56815	**FEE EXPEDITE PER APPLICANTAddition to an (E) rooftop solar system of 20 modules, 3.8kW ACAdd:(14) KU2656ZPA(1) PVI-3.0-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6978	19041-10000-23855	5040 N LANKERSHIM BLVD	91601	2	171B173  1059	2353008034	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	07/17/2020 12:00:00 AM	PIN	34.16212502	-118.37258298	T-24 PLAN CHECK FOR TI TO A CHANGE OF USE FROM RETAIL TO DONUT SHOP. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1350 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6979	12041-20000-00139	18921 W BRAEMORE ROAD	91326	12	216B121   172	2820015004	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.29092	-118.54572	Enphase inverter PV system on roof of single family dwelling.  A variance to install Enphase M215 inverters was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6980	12041-10000-25231	6501 N TOPANGA CANYON BLVD	91303	3	180B101   634	2139002029	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	ADDRESS	34.1883	-118.60612	NO CHANGE OF USE-TENANT IMPROVEMENT IN A RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6981	09041-20005-05355	9480 W READCREST DR	90210	4	147B165   347	4352010046	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2011 12:00:00 AM			PC Approved	10/14/2011 12:00:00 AM	ADDRESS	34.09824	-118.40466	revision only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6982	19041-20000-35187	9333 W KIRKSIDE ROAD	90035	5	129B169   901	4306021015	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.04854	-118.39254	PV1. INSTALL 8.8 KW DC SOLAR SYSTEM WITH (22) AC MODULES ON EXISTING 400 AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6983	13041-10000-01009	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	33.94221	-118.40701	T24 for installing LED internally illuminated sign	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6984	14041-10000-25634	14630 W WYANDOTTE ST	91405	6	186B149   789	2218023025	R3-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Apartment			09/17/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.20289	-118.45203	permit fee is 0.00 due to Senate bill 1222.Installation of new rooftop solar photovoltaic system on multi-family affordable housing apartment building.  Total system size = 30 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
6985	13041-20001-11563	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.09818	-118.32309	Modifications to approved set.  Additional distribution equipment and minor changes to layout of equipment on floor plans.  Will submit approved set before assignment.  (((AS PART OF THE COLUMBIA SQUARE REDEVELOPMENT, TWO BUILDINGS SHARING A CONNECTING CANOPY WILL HAVE THE CANOPY REMOVED. A BUILDING PERMIT WAS ISSUED FOR  EACH BUILDING-6125 W SUNSET BLVD HAVING 6 FLS AND 6121 W SUNSET BLVD HAVING THREE FLOORS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6986	18041-10000-03775	2739 S MANSFIELD AVE	90016	10	123B177  1606	5049015025	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.02971	-118.35341	PC for 1.96kW(AC) rooftop system. Installing seven new panels (2.135kW DC) and IQ6Plus-72-2-US microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6987	17041-10000-28680	3456 S SEPULVEDA BLVD	90034	5	117B157  1179	4251028028	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.0202	-118.42274	PC FOR T24. REPLACE LIGHTS WITH LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6988	13041-10000-04952	11839 W HARTSOOK ST	91607	2	171B169   495	2355006037	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.16408	-118.39142	PV1 7.5kw dc (6.48kwAC) MICRO INVERTER 2 STORY HOUSE. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [30 MODULE: tsm-250pa05.08]. ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6989	14041-10000-03253	1458 S SAN PEDRO ST UNIT #L-27	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	T24 PART 6 ENERGY ONLY FOR 350 SQ FT COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. REPLACING TOTAL OF (1) UNITS.  ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6990	15041-20001-16378	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Issued	07/21/2016 12:00:00 AM	ADDRESS	34.04538	-118.26335	[[[[ 2/18/16  CHANGES TO APPROVED SET. ADDITION OF FIREPUMP AND JOCKEY PUMP TO THE SYSTEM REQUIRED BY MECHANIAL]]]]]]]New service upgrade and distribution equipment for assembly occupancy. new design. This is core and shell clear out of existing building. TI package will be submitted at a later date. per building submittal, PC is accordance to 2008 building efficiency standards.project is in methane buffer zone. NOT A HIGHRISE PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6991	12041-20000-19092	7209 W FOOTHILL BLVD	91042	2	202-5A199 391	2568012025	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.2489	-118.28888	T-24 lighting plan check for remodeled beauty salon.  Some  existing lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6992	14041-20000-32434	550 S HILL ST SUITE 1635	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.04753	-118.25268	TI TO AN EXISTING COMMERCIAL TENANT SPACE IN A HIGH RISE BUILDING.  INSTALLING NEW LIGHTING FIXTURES INTO EXISTING PANELS.  WORK TO BE PERFOMED IN SUITE 1635.  TOTAL AREA 1,910 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6993	17041-10000-02969	13350 W GRIDLEY ST	91342	7	222B157   271	2512004006	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.30529	-118.4242	PC FOR PV SYSTEM 6KW AC USING MICROINVERTER SYSTEM TOTAL OF 25 MODULES. ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
6994	16041-10002-07976	17331 W PARTHENIA ST	91325	12	195B129   402	2768016005	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.2287	-118.51244	FEES ARE $0 DUE TO SENATE BILL 1222.07/27/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE MADE UNDER DELTA 2. CHANGES INCLUDE REMOVING TWO MODULES, RELOCATING THE PV MODULES ON THE ROOF, AND ADDING A SUNPOWER SOLAR MONITOR. NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-07976(((((PV1, NEW 15.70 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(48) MODULES: SUNPOWER SPR- E20-327-C-AC(48) MICROINVERTER: SUNPOWER E20-327-C-AC-GEN 2.2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
6995	12041-10000-09339	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.2426	-118.55846	REMODELING TO EXISTING SUPERMARKET W/ ADDITION OF METAL CANOPY AT LOADING DOCK AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6996	13041-10000-23823	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-2, C2-4, M3-1	Central	Central City North, Westlake	Historic Cultural		2089.02	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.05562	-118.27458	PROPOSED CHANGE OF USE FROM AN EXISTING RETAIL SPACE TO A  7626 SF RESTAURANT. TENANT IMPROVEMENT TO CREATE RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6997	11041-20000-25757	616 N NIMES ROAD	90077	5	144B153   893	4362025006	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2011 12:00:00 AM			Reviewed by Supervisor	01/20/2012 12:00:00 AM	ADDRESS	34.08726	-118.43754	Remodel residential estate.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6998	16041-10000-45511	3921 W WILSHIRE BLVD	90010	10	135B193  1028	5504028***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/16/2021 12:00:00 AM	ADDRESS	34.06188	-118.31234	Plan check for power and energy.  Adaptive re-use of existing 7-story low rise commercial bldg (T.I. at basement and 1st floor commercial, change use on floors 1-7 from commercial to 101 residential units.  Convert basement from office to exercise room and storage.  Convert 1st floor from adult daycare to retail and residential apartments.  Convert floors 2 to 7 from office to residential apartments.       Building permit #13016-10000-26034       Fire alarm separation variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
6999	17041-10000-30263	2917 W TEMPLE ST	90026	13	139-5A203 445	5156014010	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village	YES	1958.02	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.07449	-118.27896	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7000	13041-20000-16865	657 W REDONDO BEACH BLVD #1	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	33.89279	-118.28709	Change of use from Retail to Restaurant.  Occupancy load is less than 46 per applicant.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7001	17041-20001-11241	11500 W OLYMPIC BLVD	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM			PC Approved	06/28/2017 12:00:00 AM	ADDRESS	34.03624	-118.44415	"6/28/17Changes to an approved set of plans.  emergency lighting for stairwells to be connected to existing onsite generator. this is plan check only.(((PLANCHECK FOR EMERGENCY LIGHTING IN STAIRWELLS. ""COMPLY WITH DEPARTMENT ORDER effective date11/30/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"")))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7002	09041-10001-24500	4915 S VERMONT AVE	90037	9	111B197  1090	5017027031	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	Apartment			01/27/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	05/10/2012 12:00:00 AM	ADDRESS	33.99832	-118.29191	Change the priviously approved plan. Plan check is for delta 1& 2. (((((((((((LOW INCOME FAMILY APARTMENT PROJECT - 49 APARTMENTS. Variance to separate the electrical and fire alarm plans was submitted on September 9, 2010.))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7003	19041-10000-35397	4433 N BECK AVE	91602	2	165B169   157	2365006013	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.15122	-118.38349	NEW ROOF MOUNTED 8.8KW PV SYSTEM WITH (24) PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7004	16041-10001-05668	2674 E ROSEVIEW AVE	90065	1	145-5A219 123	5453003019	RD3-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.09386	-118.22693	Change on approved plan: reduced number of modules to (29). Other remain the same. Zero ($0) additional fee due to California Senate Bill 1222.Permit# 16041-10000-05668***PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. STANDARD PLAN IS BEING USED. (33)MODULES-SOLARCITY STANDARD(1)INVERTER-FRONIUS #PRIMO 7.6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7005	11041-10000-10855	2551 W BEVERLY BLVD	90026	13	136-5A203  98	5157001019	C2-1	Central	Westlake	Greater Echo Park Elysian		2086.20	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM			PC Approved	05/26/2011 12:00:00 AM	PIN	34.0693901	-118.27601164	TI TO AN EXISTING OFFICE BUILDING.  T-24 WITH EMERGENCY, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7006	18041-30000-47306	970 W 190TH ST Suite 550	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	33.85812	-118.29302	Plan check for Title 24 only. Project site is a tenant suite in an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 4,510 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7007	12041-20000-11726	8735 N TAMPA AVE	91324	12	195B117   167	2783027029	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.2293	-118.55375	new bakery cafe	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7008	19041-20000-41031	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7009	19041-10000-29710	762 E SLAUSON AVE	90011	9	108B205  1511	6007002027	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.98904	-118.26117	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7010	16041-20000-02387	22854 W HARTLAND ST	91307	12	183B097   798	2026008011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.19447	-118.62531	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. Standard plan in use.(21) LG 300 NK Modules(1) ABB PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7011	18041-20002-34470	8985 W VENICE BLVD	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.02733	-118.39241	SUPPLEMENTAL PLAN CHECK ONLY, CLOUDED CHANGES ONLY, REMOVAL OF GROUNDING CONDUCTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7012	17041-10000-43213	1245 E FACTORY PL	90013	14	126A215   200	5164001007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.03928	-118.23682	REPLACE EXISTING FIXTURES WITH LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA 18200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7013	15041-10000-38657	8248 W MANNIX DR	90046	4	150A175   254	5556004037	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Expired	12/18/2017 12:00:00 AM	ADDRESS	34.1055	-118.37082	pv1 sfd. total 6kw ac using 2 central inverters. total of 26 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7014	13041-20000-17697	5824 N RADFORD AVE	91607	2	174B169   148	2339008013	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.1765	-118.39101	PV1 MICROINVERTER. TOTAL SYSTEM SIZE: 6.28KWAC. 29 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7015	12041-10000-05091	5638 W TUXEDO TER	90068	4	153A191   172	5587002033	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2012 12:00:00 AM			Corrections Issued	03/15/2012 12:00:00 AM	ADDRESS	34.11426	-118.31487	Install roof mounted solar, SFD. Interconnect with main service panel. 5.17 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7016	17041-20000-13151	6802 N ALDEA AVE	91406	6	183B133   968	2230002012	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.19421	-118.50823	Plan check for a PV1 roof-mounted PV system. System size is 19 kWac and consists of (3) inverters, (65) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7017	12041-20000-11837	920 W 37TH ST	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	PIN	34.02030756	-118.28890608	Install a new manhole and replace feeder for existing manholes for the underground high voltage services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7018	10041-30000-06880	11684 W SAN VICENTE BLVD	90049	11	129B145    37	4265006063	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	34.05358	-118.46475	SIGN LIGHT FOR STORE FRONT. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7019	15041-20000-28715	6011 S WEST BLVD	90043	8	105B185   477	4004031019	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	33.98493	-118.33539	"""0$ permit fees due to senate bill 1222""PV2 COMMERCIAL ROOFTOP SOLAR. PC FOR NEW SOLAR SYSTEM TOTAL OF 148 MODULES AND 3 CENTRAL INVERTERS. NEW SOLAR LOAD CENTER. INTERCONNECTED TO NEW SERVICVE PANEL (UNDER SEPARATE PERMIT) TOTAL SYSTEM SIZE 33KW AC"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7020	16041-20001-43889	20549 W CALIFA ST	91367	3	174B109    74	2151018017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/19/2016 12:00:00 AM	ADDRESS	34.17626	-118.58154	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A solar ready MSP. 13.6kW (7.6+6) ungrounded system. (72) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7021	18041-20002-22471	9843-9853 N MASON AVE Bldg 5	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	34.24903	-118.58076	PLAN CHECK ONLY, SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY ADDING NEW LIGHT FOR BATHROOM. <<<FULL PC FOR A CORE AND SHELL FOR NEW 1-STORY BUILDING WITH RETAIL AND RESTAURANT SPACES.. SCOPE OF WORK INCLUDES NEW 3000A SERVICE, WITH TENANT PANELS AND COMMON AREA CIRUITS. BUILDING 5 TOTAL SQ. FT. FOR OUTDOOR 5878 INDOOR 10435.B#18010-10000-01050>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7022	16041-20000-02561	3883 S DEGNAN BLVD	90008	10	117B185   940	5033012023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.01508	-118.33014	Plan check for PV roof mounted system. System size: 3.8kW with 15 Canadian solar panels with 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7023	13041-10000-26675	2840 W FRANCIS AVE	90005	1	132B197   645	5077025008	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			09/26/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.05662	-118.28778	FULL PLAN CHECK FOR POWER AND ENERGY IN A 28 UNIT APARTMENT. 1200A SERVICE OVERHEAD. APPROXIMATELY 30902 SF OF LIGHTING (INDOOR + OUTDOOR).  FEES WERE BASED OFF THE MAX # OF CKTS & MOTORS FOR HEAVIEST LOADED PANEL DONE PER APPLICANT REQUEST. TOTAL BR = 659. APPLICANT STILL OWES FEES FOR 69 BR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7024	17041-10000-30183	19600 W PLUMMER ST Suite 600	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.2426	-118.5602	First tenant in new commercial spaceplan chk is for title 24 and power	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7025	13041-10000-09644	8140 N SUNLAND BLVD	91352	6	189B173    58	2409002032	[Q]C2-1VL-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.10	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.21818	-118.36955	NEW FIRE ALARM SYSTEM FOR 2 STORY COMMERCIAL BUILDING. 1 FIRE ALARM PANEL AND 126 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7026	18041-20000-06476	720 N HIGHLAND AVE	90038	4	141B185   470	5524011026	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Issued	03/20/2018 12:00:00 AM	ADDRESS	34.0842	-118.33839	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,314 sq. ft.Note: Building permit has been issued under 18016-10000-03756	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7027	13041-10001-34609	13929 W DEL SUR ST	91331	7	210B153   507	2616023007	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.27241	-118.4366	Expedited RSES plan check per applicant request.{{PV1, Install 6.25 kw DC roof-mounted solar array system for a residential house, interconnect with main service.(1)Transformerless inverter[ SOLAREDGE SE6000A-US] and (25)modules[TRINA SOLAR TSM-250PA05.18].}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7028	18041-20001-23844	14921 W OTSEGO ST	91403	4	171A149   150	2263005006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM			PC Approved	08/07/2018 12:00:00 AM	ADDRESS	34.16308	-118.45818	Revisions to approved set of plans.  Removal of ESS from plan design.  $0 plan check fee per State Senate Bill SB 1222 and AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7029	10041-10000-13355	9301 N TAMPA AVE OLD NAVY	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM			Verifications in Progress	07/28/2010 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI IN AN EXISTING RETAIL SPACE, (OLD NAVY) SPACE #42 IN NORTHRIDGE FASHION CENTER. PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7030	12041-20000-22080	773 S TOWNE AVE	90021	14	126A213   592	5146027025	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			09/17/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.03804	-118.24708	Plan check for energy only at counter (617 sq.ft Warehouse).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7031	11041-10000-26307	735 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM			PC Approved	12/09/2011 12:00:00 AM	ADDRESS	34.04878	-118.26079	smoke control system.  permit issued under   11041-10000-26302.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7032	15041-10000-03011	12400 W WILSHIRE BLVD 4th	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.04157	-118.47031	Title 24 plan check only.  Total area = 800 sq. ft.T.I. to corridor in existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7033	17041-20000-03708	700 S FLOWER ST Ste 2650	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to (E) commercial office space.   Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7034	12041-10000-13401	7813 S COWAN AVE	90045	11	099B165    99	4109022027	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2012 12:00:00 AM			Reviewed by Supervisor	06/26/2012 12:00:00 AM	ADDRESS	33.97097	-118.40384	Plan check for new 7.395KW roof mounted photvoltaic system with transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7035	11041-20000-00123	17828 W CHATSWORTH ST	91344	12	207B129   452	2733005005	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM			Corrections Issued	01/04/2011 12:00:00 AM	ADDRESS	34.26466	-118.52259	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7036	19041-10000-32822	3400 W OLYMPIC BLVD 1st Floor	90019	10	129B193   344	5081031025	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.05245	-118.31249	ENERGY PC ONLY, CHANGE OF USE FROM (E) RETAIL TO (N) ADULT DAY CARE FACILITY ON THE FIRST FLOOR. AREA 9750SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7037	14041-10000-30249	19310 S PACIFIC GATEWAY DR	90502	15	057B197     9	7351031030	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	33.85616	-118.29473	Energy plan check for a T.I office. total area covers 15000 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7038	16041-10000-13627	1330 W PACIFIC COAST HWY	90710	15	033B197    21	7411007021	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Expired	07/24/2018 12:00:00 AM	ADDRESS	33.78921	-118.30005	PV2 ROOFTOP SOLAR ENERGY. TOTAL SYSTEM SIZE 32KW AC USING 2 CENTRAL INVERTERS CONNECTED TO A TRANSFORMER FOR BACKFEED TO MATCH BUILDING VOLTAGE CLASS. TOTAL OF 105 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7039	11041-10000-10369	11400 W OLYMPIC BLVD 14Th Floor	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Public Safety Only			05/20/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.03666	-118.44346	INSTALL 16 ADDITIONAL DEVICES AND A NEW FA CONTROL PANEL IN SUITE # 1400 ON THE 14TH FLOOR CONNECTED TO AN EXISTING FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7040	19041-10000-02682	2000 S AVENUE OF THE STARS Suite900 N	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM			Ready to Issue	05/29/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	TI OF 9th FLOOR, EXISTING OFFICE AREA IN SUITE # 900N. T-24 ENERGY ONLY. 23,645 Sqr Ft. Building Permit: 18016-10000-39126	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7041	15041-20000-01186	21650 W OXNARD ST Suite 150	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	TI to existing commercial high-rise office building. New lighting and controls. Existing panel. Plan check for energy and emergency only. Total sqft. 2273.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7042	10041-10001-25272	1413 N L. RON HUBBARD WAY	90027	13	147B197   870	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Info Complete	09/02/2011 12:00:00 AM	ADDRESS	34.097	-118.29419	"TI for an existing 5 story building. EPC is for power and energy.  <<<<<<<<<<<MODIFICATION TO AN APPROVED SET OF PLANS,  CHANGES ARE ""MOSTLY"" FOR LIGHTING PER CUSTOMER  (NOT ALL CHANGES ARE CLOUDED, ADDITIONAL FEES MAY NEED TO BE COLLECTED)>>>>>>>>>>>>>>>>**Permitted and finaled under separate PCIS# (per applicant)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7043	19041-20000-01303	5805 N SEPULVEDA BLVD Suite 610	91411	4	174B145   102	2243001009	M1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM			PC Info Complete	01/17/2019 12:00:00 AM	ADDRESS	34.17593	-118.46647	Plan check for power and energy for Medical Office Tenant Improvement. Total area: 2272 sq ft. B#17016-10000-33982	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7044	15041-20000-31534	3669 E WHITTIER BLVD	90023	14	121-5A229  71	5188008027	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.02484	-118.19388	TI to existing commercial building (retail). Plan check for energy only. Adding new lighting including emergency. Total sqft. 4,762.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7045	13041-10000-26298	10006 N MONTGOMERY AVE	91343	12	204B141  1036	2669019019	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.25228	-118.48155	PV1 ROOF-MOUNTED 2.94KW PHOTOVOLTAIC SYSTEM WITH POWER OPTIMIZERS (12) MODULES: TRINA #TSM-245PA05.18(1)SOLAREDGE #SE3000-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7046	19041-20000-42433	13410 N MANZANILLO LANE	91342	7	225B157  1053	2510026018	(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.31531	-118.42212	Plan check for PV roof mounted system, PV System size: 1.68KW with 7 PV Modules and 7 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7047	14041-20000-02830	6960 N RUBIO AVE	91406	6	183B137   280	2225006034	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Expired	03/09/2016 12:00:00 AM	ADDRESS	34.19729	-118.49548	PV1 SINGLE FAMILY DWELLING. TRANSFORMERLESS INVERTERS USING POWER OPTIMIZERS. 7.6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7048	19041-20000-43133	2049 S CENTURY PARK EAST 26TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	12/29/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 Energy only, lighting,newly connected load less than 400A. Total area: 23,187 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7049	17041-20000-24365	13310 N DE FOE AVE	91342	7	225B145   455	2501022064	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.31322	-118.46088	pv1install roof mounted pv system sized 10.3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7050	15041-20000-42586	8819 N RANCHITO AVE	91402	6	195B153   613	2639037024	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.23091	-118.43957	Plan check for PV roof monted system. System size: 7.6kWac with 28 modules and 1 inverter(7.6kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7051	10041-10000-02641	425 S SOTO ST	90033	14	126A223    76	5183014036	C2-1, P-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2046.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	04/23/2010 12:00:00 AM		Permit Finaled	06/22/2010 12:00:00 AM	ADDRESS	34.0398	-118.21254	Plan check T-24 energy (general/emergency lighting) for new lighting work in an existing Carl's Jr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7052	17041-10001-32993	11906 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Issued	02/22/2018 12:00:00 AM	ADDRESS	34.05239	-118.47055	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD CHANGES TO LIGHTING. SCOPE INCLUDES REVISIONS TO LIGHTING LAYOUT AND T-24 REVISIONS. ADDING NEW TRACK LIGHTING PANEL WITH TRACK CIRCUITS.INSPECTOR TO VERIFY STICKER WATTAGE ON P6 FIXTURES.PC FOR RESTARUANT/CAFE  TI FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD <400A SCOPE INCLUDES NEW PANEL CIRCUITS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1202 SQ.FT.  B# 17016-10000-24783	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7053	18041-10000-11501	5822 S VERMONT AVE	90044	9	108B197  1460	6004001031	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	33.9889	-118.28954	T.I. TO (E) CVS TO CREATE (N) OPTICAL AREA AND (N) SIGNAGE;PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7054	15041-10000-30440	19200 S WESTERN AVE	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Expired	10/11/2017 12:00:00 AM	ADDRESS	33.85755	-118.30917	PC for energy only, t-24 to an existing commercial building (wherehouse). Scope of work includes new lighting. Existing lighing controls to remain.  SqFt = 188,772.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7055	18041-10001-20354	1607 E PLEASANT AVE #2	90033	14	129A221    80	5174024026	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.04838	-118.22052	2 OF 2*****EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7056	16041-10000-40141	1555 E NEWTON ST	90021	14	121-5A213 342	5130020021	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.02538	-118.24168	PC FOR 5000A SERVICE UPGRADE. SHELL OUT EXISTING BUILDING AND PREPARING FOR NEW TENANTS. THIS SCOPE IS FOR SERVICE WORK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7057	14041-20000-03085	4908 N VARNA AVE	91423	4	168B157   203	2359012013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.15981	-118.42455	PV1 SINGE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.7KW AC USING 22 MODULES. USING ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7058	15041-20002-23805	21514 W SATICOY ST	91304	3	186B105   164	2111005005	(T)(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Apartment			04/13/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.20807	-118.59943	04-13-2018 Changes to an permitted set of plans. Changes include added outdoor lighting Title 24 form, lighting fixture wattage reduced . All Changes has been clouded as delta 6. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7059	16041-10001-26899	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.32381	-118.49103	RECHECKING T24 FOR LOST SET OF PLANS. RESTAMP AND ISSUE PERMIT UNDER MASTER APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7060	12041-10000-06297	1510 W PALOS VERDES DR NORTH BLDG E	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77938	-118.30397	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building E. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7061	17041-10000-31211	2000 W 7TH ST	90057	1	132A203   147	5141019009	C2-2	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Issued	08/31/2017 12:00:00 AM	ADDRESS	34.05587	-118.27584	PC for T24 only for removal of outdoor metal halide fixture  and replacewith new LED fixtures. Total of 2625sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7062	11041-20000-01083	13904 W SATICOY ST	91402	6	186B153    34	2214023021	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.21016	-118.43582	PLAN CHECK FOR ROOF MOUNTED 7.59KW AND 7.59KW PHOTOVOLTAIC SYSTEMS WITH 2 EXISTING SERVICES SUPPLYING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7063	11041-10000-23327	820 S SPRING ST	90014	14	127-5A211 243	5144016047	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.04255	-118.25395	Remodel to an existing 14 Room hotel with New 600A Service.  Plan check for POWER and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7064	15041-10000-31296	10940 W WILSHIRE BLVD STE 1700	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.05822	-118.4452	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN  SUITE 1700.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7065	15041-10000-34757	12817 W VICTORY BLVD	91606	2	180B161  1045	2325032007	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.18684	-118.41241	T-24, TI TO AN (E) OFFICE SPACE, SCOPE INCLUDES NEW LIGHITNG AND RECEPTACLE. PC FOR ENERGY ONLY.  TOTAL SQ. FT. 7347	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7066	18041-20000-45932	12458 W MAGNOLIA BLVD	91607	2	171B165  1236	2356020023	R1-1, RD1.5-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	02/02/2021 12:00:00 AM	ADDRESS	34.16467	-118.40467	TI to (E) commercial retail space.  Plan check for energy - 2348 sq ft.Partial permit fees for (17) branch circuits paid under 19041-90000-00744.  Permit fees for this application assessed based on the unpaid portion of the overall project scope permit fees required.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7067	19041-10000-04448	15015 W CORONA DEL MAR	90272	11	123B129   637	4411024007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM			Reviewed by Supervisor	02/12/2019 12:00:00 AM	ADDRESS	34.03183	-118.52283	INSTALLING 2 NEW TESLA WALL MOUNTED ENERGY STORAGE SYSTEMS 5KW EACH TO AN EXISTING SOLAR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7068	16041-20000-10555	5757 W WILSHIRE BLVD STE 270	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.06259	-118.35341	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 7376 SQFT SUITE 270	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7069	18041-20000-38944	1505 N EDGEMONT ST	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	01/22/2021 12:00:00 AM	ADDRESS	34.09843	-118.29637	ti to an existing commercial building(medical, consultation only.)  adding new lighting new controls to existing panels.  plan check for energy only,one for one replacement of an existing fluoroscopy equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7070	13041-10000-31705	2027 S STONER AVE	90025	11	123B149   274	4262032901	PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.03582	-118.4508	PLAN CHECK POWER AND ENERGY FOR EXISTING  FOR A TRUCK/SWEEPER MAINTENANCE FACILITY LGC/CNG. INSTALLATION OF NEW STANDY-BY POWER, SWITCHBOARD, EQUIPMENT, CIRCUITS, AND PANELS.NOTE: GAS MONITORING SYSTEM UNDER #13041-10000-31707	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7071	11041-20000-22870	221 N ARDMORE AVE	90004	10	138B193   521	5517022009	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM			PC Approved	10/25/2011 12:00:00 AM	ADDRESS	34.07596	-118.30203	Plan check T24 Energy/Emergency lighting for TI of existing office space. Permit under #11041-90000-20030	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7072	19041-10000-34081	620 E G ST	90744	15	030B209   203	7424010036	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	33.78015	-118.25568	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7073	10041-10000-01884	3401 E WHITTIER BLVD	90023	14	121-5A227  87	5188004043	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.0278	-118.20065	T.I. for existing gas station.  Replace switchboard, new service, add new panel, equipments, branch circuits, and new interior lighting.  Plan check for power and energy.  Per DWP Service Planner max 42KAIC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7074	14041-20000-09019	6622 N PETIT AVE	91406	6	180B137   232	2231016031	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Expired	05/02/2014 12:00:00 AM	ADDRESS	34.191	-118.49666	pv1 single family dwelling. total system size 6.8 kw ac using transformerless inverter nonstandard plan. 2 strings / inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7075	14041-10000-13342	14959 W LANARK ST	91402	6	189B145    22	2209010002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.21801	-118.45947	PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7076	13041-10003-13166	21411 W PRAIRIE ST	91311	12	198B105    80	2746014003	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM			PC Info Complete	04/30/2014 12:00:00 AM	ADDRESS	34.2392	-118.59803	"changes to approved plans:  load increase . addition of panels: heq3 and acd fed from new section attached by wireway to existing main switchboard ""MS"". addition of 3 outlets , 3 lights. Changes on plan include details about connection between old MS and new section."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7077	19041-10000-18481	12561 W MILTON ST	90066	11	105B157   475	4221026021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	33.98438	-118.42027	(ePlan) PV1. New 7.6 kW AC Roof Mounted Solar w/ (1) 13.5 kWh ESS. Install (1) 7.6 kW inverter, (20)  Modules with (20) P400 optimizers, (1) Energy Storage System @ 13.5KWH & (2) New 200A Load Centers. System connect t (E) 100 MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7078	18041-10000-46108	11150 W SANTA MONICA BLVD 330, 350	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLAN CHECK FOR TITLE 24 ONLY FOR AN EXSITING OFFICE HIGHRISE BUILDING. SCOPE OF WORK INCLUDES LIGHING AND NEW EQUIPMENT WITH TOTAL SQFT OF 9086. BLD# 18016-10000-38275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7079	15041-10000-09767	24454 W CLIPSTONE ST	91367	3	177B089   727	2032013063	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.17841	-118.65709	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECTED WITH MSP.(38) SUNPOWER 327 WATTS MODULES(2) SMA SUNNY BOY INVERTERS 6 AND 5 KW INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7080	16041-20000-25764	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	PLANCHECK FOR POWER. REPLACEMENT OF A 3000AMP DIMMER SWITCHBOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7081	13041-20000-28368	1901 S AVENUE OF THE STARS STE 900	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.05949	-118.41705	Plan check for energy and emergency lighing. Commercial high-rise office. Suite 900, 9th floor. Susman Godfrey LLP.(((change in plans, new pc performed.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7082	17041-10001-07860	6719 S LA TIJERA BLVD	90045	11	102B173   831	4102001028	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM			PC Info Complete	10/05/2017 12:00:00 AM	ADDRESS	33.9779	-118.37141	Changes to an approved set of plans. Changes to reflect what is the field. Title 24 plan check. checking for disaggregation of electrical load. All changes are under delta 11.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7083	19041-20000-34961	1418 N AVENIDA DE CORTEZ	90272	11	138B117   233	4431007016	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.0734	-118.56289	Plan check for new Energy Storage System, Energy storage system size: 27KWh with 2 Tesla battery(13.5KW), sub panels	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7084	10041-10000-05107	15541 W LANARK ST	91406	6	192B145   618	2654038013	M2-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	06/03/2010 12:00:00 AM	ADDRESS	34.21869	-118.47164	TI IN AN EXISTING STUDIO SHOW ROOM / OFFICES. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS & EMERGENCY LIGHTS. PERMIT IS FOR ADDITIONAL NEW  (20) CIRCUITS FROM PERMIT 10041-20000-07591.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7085	16041-10000-39225	1620 N SILVER LAKE BLVD	90026	13	144A205   335	5425023009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.08847	-118.26889	Plan check per applicant request.Full plan check for a restaurant located in a single lot with 2-building and 1-address. Scope include 1-services of  400-Amp and 2-panel (1 per each building ). all electrical equiptment is new; total area is 2100-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7086	12041-10001-15657	9641 N ODESSA AVE	91343	12	201B137   705	2677006006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.24586	-118.49196	revised permitted set of plans- replacing the single 7kw inverter with a 3.6kw and a 5kw inverters.AS-BUILT SET OF PLANS((((((Plan check for PV System. SIngle Family dwelling. 7.848 kW DC. Transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7087	14041-20000-09705	22733 W HAMLIN ST	91307	12	180B097   377	2038022011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.18904	-118.62235	PV1 system, roof-mounted on existing residential single unit with 24 modules and 6kw.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7088	19041-10000-44553	7344 N LAUREL CANYON BLVD	91605	2	186B165   550	2317015009	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.20413	-118.39608	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7089	16041-10000-35209	718 E JACKSON ST	90012	14	130-5A217 325	5173015006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.0509	-118.23282	Plan check Title 24 only T.I. to health club. occ load less than 100 in exising building. Total Title 24 area: 6,954 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7090	18041-10000-25162	1101 E 18TH ST	90021	14	121-5A211 307	5131002019	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.02622	-118.25154	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7091	17041-10000-02759	8500 W BEVERLY BLVD 656	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			Corrections Issued	01/27/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	T-24, PC FOR ENERGY ONLY. TI OF AN (E) RETAIL SPACE IN A COVERED MALL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A FOOT LOCKER RETAIL STORE. TOTAL AFFECTED AREA IS 7580 SQ. FT.  B#17016-10000-00643	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7092	18041-10001-17940	3550 S OVERLAND AVE	90034	5	120B161   895	4314011050	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			06/12/2019 12:00:00 AM			PC Approved	06/19/2019 12:00:00 AM	ADDRESS	34.02383	-118.41069	"DELTA ""1"" CHANGES TO APPROVED PLANS TO USE ""SILENT KNIGHT IFP-2000"" FIRE ALARM PANEL INSTEAD OF ""MIRCOM"".  <<<New Fire alarm system (224) devices, (1) FACP on New 5-story 60-unit affordable housing apartment over 2-levels of subterranean parking. 24 Typical units.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7093	15041-20000-07796	11254 N WOODCOCK AVE	91331	7	210B157   131	2534006001	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.27464	-118.41952	Plan check for a PV1 roof-mounted PV system. System size is 3.44 kWac and consists of (16) modules and (16) micro-inverters. Standard plan is not being used. Note: contractor has a B contractor license.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7094	16041-10002-20095	301 W OLYMPIC BLVD Loit LA	90015	14	127-5A209 251	5139004026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			PC Approved	04/21/2017 12:00:00 AM	ADDRESS	34.04182	-118.25852	04-21-2017 Changes to an approved set of plan. Changes include reduce panel PC to lower ratting. Changes has been clouded . B# 16016-10000-09083	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7095	18041-10000-22938	1811 N JOHNSTON ST	90031	1	135A223   119	5210016014	M1-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.06474	-118.21031	PLAN CHECK FOR T24 ONLY,  TENANT IMPROVEMENT TO AN EXISTING INDUSTRIAL BUILDING. NEW DRYWALL AND REMODEL EXISTING RESTROOM. INSTALL NEW LIGHTS AND RECEPTACLES, AREA: 6040 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7096	17041-10000-42933	13016 W RUNWAY ROAD	90094	11	102B157   224	4211021263	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM			PC Info Complete	12/13/2017 12:00:00 AM	ADDRESS	33.97356	-118.42325	PC FOR ENERGY ONLY. NEW LIGHTS FOR OUTDOOR WALKWA Y EVENT AREA. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 11968sqft. 17010-10000-03365	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7097	15041-10000-16112	34 W ST JAMES PARK	90007	1	123A203   157	5124024011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.03121	-118.28053	Conversion of (E) overhead utility service to underground and upgrade of site lighting.  Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7098	18041-30001-06421	300 N VIA NICOLAS	90272	11	126B117   124	4416002015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.044	-118.55426	02-22-2018 Changes to an approved set of plans. Changes include AIC ratting of the load center to 10kAIC and conductor size from 8 AWG to 10 AWG form J-Box to the load Center. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7099	19041-20000-53258	7323 W ALPINE WAY	91042	7	213B197   115	2552010011	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.27635	-118.29198	Plan check for PV roof mounted system, PV system size: 11.4KW with 36 PV Modules and 1 inverters, Energy Storage System size: 40.5KW with 3 Energy Storage Devices.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7100	19041-10000-08254	8801 N KESTER AVE	91402	6	195B149   482	2653006***	OS-1XL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.2302	-118.45762	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7101	16041-20000-02201	20790 W NORDHOFF ST Unit 3	91311	3	198B109   218	2780001059	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			Corrections Issued	01/21/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	First-time tenant TI.  Plan check for power.  Title 24 plan check performed under 15041-20000-39378.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7102	19041-20000-06673	7420 S LA TIJERA BLVD	90045	11	099B173  1101	4104019003	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	08/13/2021 12:00:00 AM	ADDRESS	33.97007	-118.37961	Plan check for power and energy for New 2 story residental Elderly Care Facility Service size: 2500A 120/208Volt. Total area: 41,559 sqft. B#18010-10000-05832	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7103	18041-10001-21087	5335 W ADAMS BLVD	90016	10	123B177   923	5043002010	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.03268	-118.3593	PLAN CHECK FOR CHANGES TO  APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 9. SCOPE OF WORK INCLUDES CHANGING SERVICE SIZE, AND FAULT CURRENT CALCULATIONS, CHANGING FEEDER SIZES FOR RESEDNITAL SECTION, AND UPDATING LOAD CALCULATIONS FOR THE RETAIL AREA. IRGINAL SCOPE: ((PLANCHECK FOR POWER AND ENERGY. NEW 3 STORY MIXED USE BUILDING WITH 60 UNIT APT.BUILDING PERMIT #  17010-10000-01522))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7104	17041-20000-32368	18946 W KNAPP ST	91324	12	198B121   566	2762025017	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.23821	-118.54651	PV1. ADDITION TO EXISITING PV SYSTEM. SYSTEM SIZE: 3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7105	17041-20000-44388	21524 W NORDHOFF ST	91311	3	195B105     9	2779018004	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.23524	-118.59951	Plan check for Title 24 only. Project site is a new covered patio in the front of an existing one-story office building. Project scope is outdoor lighting. Total lighting area = 380 sq. ft.Note: Building application has been generated under 16014-20000-00058	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7106	17041-20000-42061	8541 W CHARL LANE	90046	4	156B169   447	5565043010	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.12003	-118.38679	Plan check for AC coupled battery backup system rated 8kW for SFD.Existing solar system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7107	13041-10000-13166	21411 W PRAIRIE ST	91311	12	198B105    80	2746014003	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.2392	-118.59803	pc for power and energy. 3 new panels: HEQ1/HEQ2/ACD and corresponding equipment for restrooms, granulation room, blending room. maintenance office/room, and processing line powder filling & packing. TENANT IMPROVEMENT OF EXISTING SUPPLEMENT PROCSSING PLANT AND WAREHOUSE:  DEMOLISH SOME EXISTING PARTITIONS, DEMOLISH EXISTING MULTIPLE ACCOMMODATION RESTROOMS AND RELOCATE (RECONSTRUCT), RECONFIGURE SOME PARTITIONED AREAS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7108	19041-10001-04077	17383 W SUNSET BLVD	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.03917	-118.55529	CHANGES TO APPROVED SET OF PLANS FOR T24 . ALL CHANGES ARE CLOUDED UNDER A1 ANDEDUM ONE . CHANGES INCLUDE REVISING LIGHTING FLOOR PLANS AND REVISINGS T24 CALCULATIONS. NOTE PERMIT FEES TO BE PAYED UNDER MASTER APPLICATION.T24 PLAN CHECK FOR OFFICE TI/REMODEL TO 2ND FLR OF EXISTING COMMERCIAL BUILDING, TOTAL SQFT'G = 2654 SF, NEW LIGHT AND POWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7109	17041-20000-03792	11249 W CALIFA ST unit c	91601	2	177B173  1395	2337013011	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Apartment			02/06/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.1777	-118.37637	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7110	12041-20000-20862	7083 W HOLLYWOOD BLVD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/04/2012 12:00:00 AM	09/05/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.10173	-118.34439	Tenant improvement for third floor of Live Nation building. Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7111	19041-10000-36761	601 S FIGUEROA ST 17th	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM			PC Info Complete	09/26/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Energy plan check for an office T.I located on the 17th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 18,237-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7112	17041-10000-40559	411 S EVERGREEN AVE	90033	14	124-5A225   2	5185013017	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2043.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.03677	-118.20478	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPE PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7113	16041-10000-24034	10990 W WILSHIRE BLVD 910, 940	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.0577	-118.44711	TI ( ENERGY ONLY) FOR OFFICE SPACE.  SUITES 910 AND 940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7114	16041-10001-16354	9132 N SEPULVEDA BLVD	91343	7	198B145   337	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			07/11/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.2368	-118.46732	07/11/16CHANGES TO APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1,2, & 3. CHANGES INCLUDES REMOVING/ADDING LIGHTING FIXTURES AND RECEPTACLES. NOTE: ORIGINAL APPLICATION IS UNDER PCIS#16041-10000-16354((((PC FOR T24 ENERGY ONLY. PC FOR LANDLORD PORTION OF MAKING VANILLA SHELL. FUTURE TI WORK UNDER SEPARATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7115	15041-10000-10541	700 S FLOWER ST #570	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	Energy plan check for an office TI (5th flr). Scope includes new lighting, new receptacles in a total area of 2792-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7116	11041-10000-09376	324 W 7TH ST	90014	14	127-5A209  13	5144014043	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.04546	-118.25432	alterations in existing retail space on the first floor of a high rise building; applicant requests for title 24 review	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7117	17041-10000-18161	310 S VAN NESS AVE	90020	4	135B189   230	5504023012	R1-1XL-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.06846	-118.31498	T-24 ONLY, REPLACE EXISTING FIXTURES WITH LED FIXTURES NO NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7118	15041-20001-36364	19645 W SHERMAN WAY BLDG 5	91335	3	183B117     7	2116001090	C2-1VL, R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.20129	-118.56157	EXPEDITE PER APPLICANT REQUEST.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 18 KWac. (70) MODULES-CANADIAN SOLAR CS6P255P(3) INVERTERS-SUNNYBOY SMA SB6000US-12(1) 125A SUBPANEL)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7119	16041-10001-40604	15001 W SUNBURST ST	91343	6	195B149    42	2651017011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.23453	-118.45864	CHANGE TO POINT OF INTERCONNECTION. INTERCONNECTING 2 INVERTERS TO 2 SEPARATE PANELS RATED 100A EACH. BOTH TIED TO SINGLE METER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7120	13041-20001-23728	17830 W TUSCAN DR	91344	12	222B129   367	2601056005	A1-1-K, A1-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.30121	-118.52321	((expedite fees))pv1 single family dwelling. tota system size 6 kw ac using 25 modules. transformerless inverter nonstandard plan. using 2 strings/inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7121	17041-10000-02287	20256 W VIA CELLINI	91326	12	219B113    91	2701046022	RE11-1-H, RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.29285	-118.57488	** Zero dollar permit fee due pe California Senate Bill 1222.PC FOR PV SYSTEM USING MICROINVERTERS. TOTAL SYSTEM SIZE 14KW USING 43 MODULES IN TOTAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7122	16041-20003-04930	11511 W TENNESSEE AVE	90064	11	123B153   233	4260016005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM			PC Approved	07/29/2016 12:00:00 AM	ADDRESS	34.03484	-118.44331	07-29-2016 Changes to an approved set of plan. Changes include show existing circuit homerun and receptacle. Changes apply to delta AB only.{{{{{{PLANCHECK FOR POWER  FOR CAR SERVICE EQUIPMENT AND GARAGE. HAZARDOUS LOCATION.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7123	12041-10000-21348	6532 N COSTELLO AVE	91401	2	180B153   697	2238019016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.18954	-118.43767	New 2.35 KW roof mounted PV system for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7124	13041-10000-34099	3065-3079 N SAN FERNANDO ROAD	90065	13	153A213    91	5458009018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			Verifications in Progress	04/17/2015 12:00:00 AM	PIN	34.11441394	-118.24493975	STOREFRONT REMODEL TO EXISTING 3-RETAIL TENANT SPACES TO CREATE TOTAL OF 6-RETAIL TENANT STORES (SHELL ONLY).  POWER AND ENERGY.  LOADS ON (E) PANELS ARE EXISTING TO REMAIN PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7125	15041-10000-22920	189 S THE GROVE DR Q60	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR ENERGY, TENANT IMPROVEMENT TO A RETAIL STORE. SCOPE INCLUDES NEW LIGHTING AND CIRCUITS < 400AMPS. TOTAL SQ. FT. 953	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7126	19041-30000-50014	23024 W ENADIA WAY	91307	12	183B097   190	2026028014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.19977	-118.62892	PV1, NEW ROFFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 7.6KWac/7.56KWdc, SCOPE OF WORK IS 24 MODULES (HANWHA Q-CELL 315W), A CENTRAL INVERTER (SOLIVIA 7.6TL) A NEW 125A LOAD CENTER. NO MPU.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7127	16041-10001-37950	1019 S SANTA FE AVE	90021	14	123A217   235	5166011006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.03092	-118.23019	12/15/2016 Changes to an approved set of plan. Changes include relocate panel and and add new receptacles in prepare area. Changes has been clouded as delta 2. Plan check per applicant request.  {{{{T-24, PC FOR ENERGY ONLY. TI TO (E) URM BUILDING CHANGE OF USE FROM MANUFACTURING TO COFFEE SHOP WITH RETAIL AREA. SCOPE INCLUDES TWO NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 2267 SQ. FT.}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7128	19041-10000-16375	3068 W SAN MARINO ST	90006	10	132B197  1064	5078005024	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.05439	-118.29641	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7129	18041-10000-33949	121 E FLORENCE AVE	90003	9	102B205   808	6011007042	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	33.97486	-118.27305	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7130	15041-20000-21567	3340 W COUNTRY CLUB DR	90019	10	129B189   626	5081023036	RE9-1-O-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.04982	-118.31564	PV1. GARGAGE ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19 KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7131	17041-10001-37507	700 W 7TH ST U240	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM			PC Approved	06/21/2019 12:00:00 AM	ADDRESS	34.04797	-118.25815	Change to an approved set by relocating equipment and lighting fixture on the flloor plan ; Revise swithgear to reflect existing site condition. all changes under delta-3, 9, 11, and 15 only. Narrative letter also included for reference.Note. Original plan checker, Mehdi. (((Ti in an existing movie theater, plan check for power and energy. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7132	14041-10001-14481	4913 S CENTRAL AVE	90011	9	111A209   155	5108018004	C2-1VL	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM			PC Approved	12/29/2014 12:00:00 AM	ADDRESS	33.99885	-118.25666	Supplamental plan check for changes to an approved set of plans. Changes include the addition of (4) lights to the exterior of the building, as well as the addition of (4) receptacles. Building application was submitted before July 1st, 2014 and the 2008 Compliance Forms have been used.(((PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. SUITE 4913, 4915, AND 4917))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7133	17041-10001-06032	1320 E 7TH ST #100	90021	14	127-5A211 173	5145001006	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM			PC Info Complete	11/09/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	Supplemntal PC for power and energy. Changes to equipment rating, addition of circuits and lights. Changes in lighting due to removal of mezzanine. All changes clouded under Delta 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7134	14041-20001-20699	8759 N ZELZAH AVE	91325	12	195B129   334	2768007006	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM			PC Approved	08/11/2014 12:00:00 AM	ADDRESS	34.23054	-118.5232	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECTED WITH MSP.(47) TRINA SOLAR TSM255 MODULES(1) SOLAR EDGE SE6000 INVERTER(1) SOLAR EDGE SE5000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7135	11041-10000-17101	4520 W SUNSET BLVD	90027	13	147B197   721	5542012033	C2-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	ADDRESS	34.0979	-118.288	TI TO AN EXISTING PHARMACY.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7136	14041-20001-28112	9423 N RESEDA BLVD Unit # A	91324	12	198B125   467	2763035025	(Q)R3-1, C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.24178	-118.53643	Plan check for first time tenant.  Install new subpanel and branch circuits.  Plan check for power only.Note: Lighting plan check approved under 14041-20000-28112	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7137	17041-10000-24151	11501 W HART ST	91605	2	183B169   203	2320001003	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.19768	-118.38235	Remove HID fixtures and replace with new LED fixtures - T 24 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7138	13041-20001-29480	2157 N STANLEY HILLS DR	90046	4	151-5A173 112	5567002028	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	34.11022	-118.37702	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12 KW AC USING TWO CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING TOTAL OF 40 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7139	18041-20001-20448	4620 N TOBIAS AVE	91403	4	168A151   112	2265007008	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM			PC Approved	06/26/2018 12:00:00 AM	ADDRESS	34.15534	-118.45184	Expedite per applicant requestPlan check for PV roof mounted system, system size: 15.2kWac with 40 modules and 2 inverters (7.6kW) Main Service 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7140	15041-10000-02110	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.06371	-118.3703	Title 24 plan check only.  Total area = 2,364 sq. ft.T.I. to existing office highrise space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7141	18041-20000-17777	20218 W SANTA RITA ST	91364	3	171B113   143	2166041027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.16663	-118.57495	PV1.  Install 10.395 kW DC roof mounted grid tied PV system.  (33) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7142	10041-20000-13011	3750 W SANTA ROSALIA DR 1-70	90008	8	114B185  1258	5032022***	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	ADDRESS	34.00802	-118.33889	sales office energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7143	19041-10000-49055	17316 W MAGNOLIA BLVD	91316	5	171B133   333	2257014040	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.16529	-118.51063	[EPLAN] INSTALATION OF A NEW ESS (TESLA POWERWALL) TO AN EXISTING PV1 SYSTEM. CONNECTED TO A 225 AMP EXISTING SERVICE. EV CHARGER UNDER SEPARATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7144	10041-10001-14772	1420 N COIL AVE	90744	15	036B213    16	7426029007	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	33.79347	-118.24241	REVISIONS TO APPROVED SET OF PLANS-ADDITION OF DC DISCONNECTS AT OUTPUT OF COMBINER BOXES AN BUIL-IN KEY TO OPERATE AC RELAY TO DISCONNECT AC POWERROOF-MOUNTED 1.5MW PHOTOVOLTAIC SYSTEM DIVIDE INTO A 500KW AND A 1.0 MW  PV INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7145	16041-10000-26544	6940 N BERQUIST AVE	91307	12	183B093   476	2026021007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.19575	-118.63438	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.0KWac.(24)MODULES-SUNPOWER E-SERIES SPR-E20-327(1)INVERTER-SUNNYBOY SB 7000TL-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7146	16041-10000-44433	801 S FIGUEROA ST 12TH &-15TH FLR	90017	8	129A207   119	5144022063	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	T-24, PC FOR ENERGY ONLY. TI ON THE 12TH AND 15TH FLOOR OF A COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS FOR OFFICE, CONFERENCE, AND BREAK ROOMS. TOTAL AFFECTED AREA IS 5334 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7147	11041-10000-09377	1800 N WHITLEY AVE	90028	4	150A187   372	5547005008	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Apartment			05/09/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	ADDRESS	34.10353	-118.33319	NEW 32 UNIT APARTMENT BUILDING WITH, GYM, AND 2 LEVELS OF PARKING ( ONE BELOW GRADE AND ONE ABOVE).  FIRE ALARM TO BE SUBMITTED SEPARATELY.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7148	17041-10000-44309	2852 S FORRESTER DR	90064	5	126B165   873	4316013003	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	01/05/2019 12:00:00 AM	ADDRESS	34.03936	-118.40382	Plan check for battery backup system for Sigle Family Dwelliing Unit, installing Powerwall 2.0 (5) backup battery system, 67.5 kWh,  new load center 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7149	14041-20001-17825	647 S FRIES AVE	90744	15	027B205   619	7440009911	PF-1D	Harbor	Port of Los Angeles, Wilmington - Harbor City	Wilmington		9800.31	Electrical	Electrical	Special Equipment			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	33.76433	-118.26419	[[1/27/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. DELTA 1 CHANGES]]]]]Plan check for power system.  Remove and replace ATS, generator, VFSs, pumps, and motors in existing industrial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7150	17041-20000-16008	11043 W HARTSOOK ST	91601	2	171B173   704	2353006015	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM			Re-Activate Permit	12/26/2019 12:00:00 AM	ADDRESS	34.16404	-118.37201	PLANCHECK FOR POWER AND ENERGY. NEW 4 STORY  16 UNIT RESIDENTIAL APARTMENT .fire alarm variance has been submittedb# 17010-20000-01360	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7151	19041-10001-09720	2486 W PICO BLVD	90006	1	129B197  1095	5056001004	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.04707	-118.29136	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDE REPLACING SWITCHES, OUTLETS AND LIGHT FIXTURES DUE TO FIRE DAMAGE IN AN EXISTIGN RETAILS SUITE. B#19016-40000-00066NOTE: PERMIT IS PAID UNDER PCIS#19041-40000-09720	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7152	14041-20002-12026	12642 W SANDHILL LANE Unit #1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	33.97765	-118.41437	REVISIONS AN APPROVED SET OF PLANS.  REMOVAL OF SMS MONITORING SYSTEM.Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 1 of 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7153	19041-10000-05754	9415 S COMPTON AVE	90002	15	094-5A213 324	6048004040	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	33.95109	-118.24627	REMOVE OUTDOOR HID FIXTURE AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7154	16041-10000-05327	2029 S CENTURY PARK EAST ste 4450	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC for energy only to a high rise builing on ste 4450 only. Adding (1) 100 A panel, lighting and receptacles. Total sq ft = 4900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7155	14041-10001-06041	1106 1/2 S EUCLID AVE	90023	14	121-5A223 195	5190006023	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.02643	-118.20987	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PVI-3.6-OUTD-S-US-Z-A(17) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7156	12041-20000-22724	17545 W CHATSWORTH ST	91344	12	207B129   400	2712027030	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM			PC Approved	09/24/2012 12:00:00 AM	ADDRESS	34.26508	-118.51698	Change to lighting to an existing retail space.  Load is less than 400 amps.  Plan check only for Energy, No emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7157	10041-20002-03607	19950 W RINALDI ST #101	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM			PC Approved	06/17/2010 12:00:00 AM	ADDRESS	34.27535	-118.56939	PER INSPECTOR REQUEST TO PLAN CHECK LOAD SCHEDULE MP-CT PANEL. T. I. IN  MEDICAL OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7158	12041-10000-25262	120 S LOS ANGELES ST	90012	14	130-5A213  98	5161016027	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM			PC Approved	10/22/2012 12:00:00 AM	ADDRESS	34.05092	-118.24262	Change of lighting in an exisisting banquet room in a hotel. Ckt and panels are existing. (Full plan check may required per inspector request)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7159	10041-10000-17925	4151 W PROSPECT AVE ROOMS 103-& 218	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			09/10/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	12/14/2010 12:00:00 AM	ADDRESS	34.10191	-118.28217	remodel a server room- remove a waal and add new luminairesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7160	13041-10000-11690	621 S WESTERN AVE # 300	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TIME TENANT IN COMMERCIAL SPACE-ALADDIN BOOK STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7161	16041-10007-39304	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	"DELTA 12 CHANGES TO APPROVED PLANS FOR SERIES RATING PANEL ""2HNB"" WITH UPSTREAM BOARD ""MSSE"" AT 65KAIC ON PAGE E.0004."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7162	11041-20000-08132	8700-8702 W PICO BLVD	90035	5	132B169  1041	4303010005	C4-1-O	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.05421	-118.38174	Service upgrade to 600 amps. and replace 2 existing panel boards  Plan check for power only. no new load added	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7163	19041-10000-30248	6000 S GRAMERCY PL	90047	8	105B193   570	6001018004	M2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	05/27/2020 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	33.98489	-118.3133	PLAN CHECK FOR POWER AND ENERGY FOR NEW SERVICE UPGRADE TO EXISTING BUILDING(OFFICE AND WAREHOUSE). NEW 800A SERVICE 120/240 SINGLE PHASE WITH 500A APPROX NEW CONNECTED LOAD. TOTAL AFFECTED AREA = 38532 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7164	17041-20000-09302	12200 W OLYMPIC BLVD ste 250	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.03195	-118.45506	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy 825 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7165	18041-20000-33755	4820 N SUNNYSLOPE AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	05/19/2021 12:00:00 AM	ADDRESS	34.1585	-118.42627	new fire alarm system with 81 devices and (1) FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7166	14041-20000-10315	11053 N MELVIN AVE	91326	12	210B117   107	2708023007	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Expired	05/03/2016 12:00:00 AM	ADDRESS	34.27151	-118.56037	PV1PV standard plan. Install roof mounted solar array on SFD. System size: 6.5kW(1) Power-One #Aurora PVI-4.2-OUTD-S-US-Z-A transformerless inverter(26) Canadian Solar #CS6P-250PX pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7167	19041-20000-47714	13263 N WHEELER AVE UNIT 2	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7168	18041-10000-09317	8359 N INDEPENDENCE AVE	91304	3	192B109   621	2779009059	R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.22152	-118.59081	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.44KWdc / 5.0KWac. (17)MODULES-PANASONIC VBHN320KA01(17)OPTIMIZERS-SOLAREDGE P405(1)INVERTERS SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7169	13041-10000-31559	22626 W BURBANK BLVD	91367	3	174B097   579	2040013015	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.17177	-118.61995	PV1, Install 3 kW DC roof-mounted solar array for 1-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 12 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7170	18041-20001-00994	6323 N LINDLEY AVE	91335	3	177B125   166	2124017003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM			PC Approved	01/14/2018 12:00:00 AM	ADDRESS	34.1843	-118.52745	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.725 KW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7171	14041-20000-05499	4632 N NATICK AVE 1-18	91403	4	168A149    80	2265002010	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Apartment			02/27/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.15544	-118.45402	PV2 FOR EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE 20KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7172	13041-10003-29379	1109 S GLENDON AVE	90024	5	132B153   180	4363022003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.06052	-118.44439	03/15/2016CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES ON DELTA 10. CHANGES INCLUDE THE SINGLE LINE LAY OUT TO ONE 800AMP SERVICE FOR ALL TENANTS IN THE BUILDING. TENANT BEING WORKED ON IS TENDER GREEN. ***** Previous Work Description *****   (((Changes to approved set.  Changes to distribution system.  Instead of being connected to two seperate swithboards, tenant space is receiving its own new service.  Changes to kitchen equipment and HVAC.  New lighting fixtures used.))) (((Supplemental to approved set- changes to architecture layout. Plan check for power and energy.  ((T.I. for new restaurant in an (E) 2-story building.  No change of use.  Proposed occupant load in excess of 200 occupants, likely A2 occupancy.  Power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7173	16041-20000-20065	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLANCHECK FOR POWER AND ENERGY ON PLAZA LEVEL. TENANT IMPROVEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7174	12041-20000-15121	760 E VERNON AVE	90291	11	111B145   989	4239005016	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2012 12:00:00 AM			Reviewed by Supervisor	07/13/2012 12:00:00 AM	ADDRESS	33.99895	-118.46576	pv system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7175	15041-20000-09937	5506 S HOLMES AVE	90058	9	108B213   285	5105011028	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	33.99266	-118.24093	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system with 16 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7176	15041-10000-23333	10250 W CONSTELLATION BLVD 1030	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Energy plan check for an office T.I located at the 10th floor of a high rise building. Scope includes new equipment, receptacles and lighting; Total 4534-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7177	18041-10000-41255	2552 W AVENUE 31	90065	1	150B213   375	5457010011	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.10887	-118.23909	PV1. NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 2.4 KWdc/2.24 KWac. PV SYSTEM IS CONNECTING TO THE POINT OF INTERCONNECTION OF A SINGLE FAMILY  HOME. (8) MODULES-SOLARWORLD SW 300 AND (8)MICROINVERTERS-ENPHASE S280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7178	12041-10000-19663	5809 N MAMMOTH AVE	91401	2	174B153   257	2246010009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.17606	-118.43248	PV1 - Plan check 6.76KW roof mounted photovoltaic system (Aurora transformerless inverter)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7179	19041-10000-42396	800 W 6TH ST 18th Flr	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	Installing new lights in the elevator lobby area of the 18th floor. T-24 Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7180	11041-10001-02953	1825 E 22ND ST	90058	14	118-5A215 107	5167006014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM			PC Approved	02/28/2012 12:00:00 AM	ADDRESS	34.01646	-118.23907	REVISED SINGLE LINE TO SHOW CHANGES HOW PANELS B AND C ARE SUPPLIED CHANGE OF USE FROM SEWING FACTORY TO COLD STORAGE WAREHOUSE- NEW SERVICE AND PANELBOARDS AND COOLER FANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7181	13041-10000-20667	1565 N UMEO ROAD	90272	11	132B133    71	4425003005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.0604	-118.50428	PV1 8.82KWDC 240V 400A service. XFMR INV. 2STORY. nonSTD. ROOFMOUNT. [( 1) INV: SMA SB 7000US][( 36) MOD: KD 245 GX-LFB]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7182	11041-10000-01604	7512 N VINELAND AVE 1-23	91352	6	186B173   448	2410001030	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.20707	-118.37012	New 600 Amp service and 23 meter for an appartment building. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7183	15041-20001-23747	4475 N LIBBIT AVE	91436	5	168B137   716	2284009008	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM			PC in Progress	08/01/2015 12:00:00 AM	ADDRESS	34.15337	-118.49346	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12.6 kWac and consists of (2) inverter, (59) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7184	15041-10000-09294	12126 W WATERFRONT DR	90094	11	105B161  1203	4211010051	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	33.98076	-118.40716	Plan check for a (2) seperate methane detecting systems located in a new 7 & 2-story building; Scope includes (19) sensors, (2) fire alarm devices, and (1 ) communication panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7185	13041-10000-35818	5858 N SHOUP AVE MAIN BLDG	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.17705	-118.6144	PLAN CHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION OF A GYMNASIUM, MECHANICAL BUILDING, TRASH ENCLOSURE AND (6,737 SF).   (1 OF 4 ) ALL FEES FOR ENERGY ARE UNDER THIS APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7186	18041-20000-06711	2601 N BOWMONT DR	90210										Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM	ADDRESS	34.11604	-118.39984	PLAN CHECK FOR POWER ONLY - PANEL FEEDS FROM MAIN HOUSE PANEL. SEE COMMENTSGUEST HOUSEMAIN APPLICATION 18041-20000-06698	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7187	15041-10000-24301	425 S PALOS VERDES ST 3rd,4th,5t-h floors	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	33.74102	-118.28156	alterations in restrooms on 3rd,4th,and 5th floors-replacing some luminaires with LEDtype and adding fluorescent luminaire on the emegency cktplan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7188	16041-10000-17115	18427 W NORDHOFF ST Unit C	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.23565	-118.53484	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT (WABA GRILL). SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1296 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7189	14041-20000-02184	8706 W OLIN ST	90034	10	123B169   518	4312003032	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Apartment			01/24/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.03476	-118.38249	PC FOR T24 ENERGY ONLY FOR PARKING GARAGE. LOW RISE RESIDENTIAL. HIGH EFFICACY LUMINAIRES IN COMMON AREAS, NO PC REQUIRED FOR COMMON AREAS. T24 GARAGE ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7190	15041-20000-32037	7107 N LUBAO AVE	91306	3	183B113   197	2135010027	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.19947	-118.56784	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7191	09041-30001-22764	777 S FIGUEROA ST fl 51-52	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM			PC Approved	01/28/2010 12:00:00 AM	ADDRESS	34.04828	-118.26116	1-28-10 - Supplemental is for changes to previously approved plans.  Changes include relocation of panels and relocation of lighting in office.  P/C is for Power and Energy :: TI - existing office space in high rise tower - Permit is for new ckts, equipment on existing panels.  P/C is for Energy and Emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7192	19041-10000-12416	3515 N EAGLE ROCK BLVD	90065	1	154-5A215 253	5457026011	[Q]CM-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	04/29/2021 12:00:00 AM	ADDRESS	34.11634	-118.23578	FULL PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT RETAIL. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING DISTRIBUTION SYSTEM. TOTAL EFFECTED AREA 1698 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7193	16041-10000-22628	6600 N TOPANGA CANYON BLVD # 2036	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR ENERGY ONLY. tenant improvement of e. retail space (#2036) TOTAL ARAE 2657 SQ FT.B # 16016-30000-12092	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7194	17041-20001-35671	18019 W VENTURA BLVD	91316	10	138B193  1029	5517009034	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.16485	-118.52493	expeditepv2install roof mounted pv system sized 60kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7195	16041-10000-45426	1701 E 41ST ST	90058	9	114A213    19	5117020030	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	01/13/2023 12:00:00 AM	ADDRESS	34.00825	-118.24282	Plan check for power and Title 24.  New 1-story manufacturing/warehouse/office building with 4,000 amp 480/277 V service.  Total area = 50,100 sq. ft. (outdoor) + 140,905 sq. ft. (indoor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7196	17041-30000-45947	1025 W 190TH ST Suite 100	90248	15	060B197   535	7351029020	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	33.85848	-118.29375	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,121 sq. ft.Note: Building application has been generated under 17016-30000-37976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7197	13041-10001-33101	7168 N SALE AVE	91307	12	183B097   884	2024040026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.20078	-118.61891	Expedited RSES plan check per applicant request.{[][]}PV1, Install 4 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE3800A-US. (16)modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7198	15041-10000-07284	4160 S LA SALLE AVE	90062	8	114B193   810	5021012003	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Expired	05/02/2015 12:00:00 AM	ADDRESS	34.00804	-118.30553	PV1 INSTALL 2.943 KW DC  ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(9)MODULES, (1)INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7199	11041-20000-23724	12216 W ADDISON ST	91607	5	171B165  1113	2356012003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.16113	-118.39944	New 3.84 KW DC roof mounted solar system for a single family residence.  There is already an existing system in place that the new system will tie into.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7200	19041-20000-20737	1116 N CHANTILLY ROAD	90077	5	144B149   114	4369037001	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM			PC Approved	09/01/2021 12:00:00 AM	ADDRESS	34.09269	-118.45716	Plan check for power only. Project site is a 2-story single-family dwelling and a guest house. Work includes an 800-amp service.Note: Building permits have been issued under 15010-30000-03688/15010-20001-03688	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7201	19041-10000-06151	10201 W PICO BLVD BLDG 101	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.04994	-118.41129	PC FOR POWER ONLY FOR AN EXISTING FOX NETWORK BUILDING. SCOPE INCLUDES TWO NEW 600KVA UPSs, 4 NEW 1000A ATSs, TWO NEW 1000A DISBRIBUTION BOARDS, AND TWO 600KVA TRANSFORMERS. NEW DISTRIBUTION BOARDS WILL FEED EXISTING BUILDING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7202	13041-10000-07182	3831 S HUGHES AVE 708	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.02242	-118.39823	T24 FOR EXISTING MEDICAL OFFICES. PSYCHIATRIC CONSULTATION ONLY. USING EXISTING BRANCH CIRCUITS. SQRFT 1005. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7203	18041-30000-34100	12012 W VALLEYHEART DR	91604	2	165B165   970	2368004021	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Apartment			09/06/2018 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	04/21/2021 12:00:00 AM	ADDRESS	34.14654	-118.39281	PC FOR POWER AND ENERGY FOR New 4-story, 21-unit, Type VA residential building over Type IA subterranean parking basement.SCOPE INCLUDES NEW 1200A 3PH 120/208V TOTLA AFFECTED AREA 18083  SQ.FT INDOOR AND OUTDOOR TOTAL 8 TYPICALB#16010-20001-05915	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7204	10041-10000-21041	2500 S NAVY WAY BLDG 500	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	11/01/2010 12:00:00 AM		Permit Finaled	12/30/2010 12:00:00 AM	ADDRESS	33.73363	-118.2408	T-24 ONLY FOR TI-BUILD NEW PARTITION WALLS TO CREATE OFFICE SPACES. REPAIR CEILING AS NECESSARY. NEW WINDOW OPENING IN EXTERIOR WALL AND NEW OPENING IN ROOF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7205	16041-10000-22791	52 E MARKET ST 1-4	90291	11	108A143   456	4226008006	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Issued	06/29/2016 12:00:00 AM	ADDRESS	33.98792	-118.47323	Installation of a roof mounted solar system in a 4-unit apartment building. Installing 12 microinverter modules rated at 250 watts each. Total size system = 3.0 kw.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7206	19041-20000-02151	17234 W VAN GOGH ST	91344	12	222B133   179	2602008023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.30618	-118.5081	pc for pv system. add a 4kw solar pv to an existing systems. 13 sunpower + 1 central inverter SMA SB4000US . 1 load panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7207	14041-20004-15782	330 N WESTLAKE AVE	90026	13	136-5A207  71	5157025043	(T)(Q)RAS4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM			PC Info Complete	11/29/2018 12:00:00 AM	ADDRESS	34.06951	-118.26652	11/29/2018changes to an approved set of plans.  changes noted delta 2 dated 03/22/2018 on plans.  changes to add panels and associated electrical equipment.  ((((07/19/2017 Extensive changes throughout. All changes have been clouded and marked as Deltas A thru C. Redesign of SLD - removed panels and transformers, some new panels relative to previously approved.  Some minor changes to underlying architectural design.  Extensive changes to lighting system.  Changes to mechanical HVAC equipment ratings.  Additional outdoor heaters.  *****Previous Work Description*****PLANCHECK FOR POWER AND ENERG. 200 UNIT APARTMENT. MIXED USE. 2 SERVICES OVER 3000 AMPS EACH. FEES CALCULATED PER ENGINEER. T24 FEES NOT CHARGED PROPERLY.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7208	12041-10000-01140	11049 W MAGNOLIA BLVD #400	91601	4	171B173   536	2350018085	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.16507	-118.37214	PARTIAL FLOOR TENANT IMPROVEMENT  IN A COMMERCIAL SPACE TO BE A TAKE-OUT RESTAURANTELECTRICAL WORK IN THIS PLAN REVIEW IS TO BE DONE BY THE LANDLORD; THE RESTAURANT TENANT WILL COME BACK TO INSTALL THE RESTAURANT EQUIPMEN;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7209	13041-20000-15664	15217 W CAREY RANCH LANE	91342	7	216B145   214	2611044003	A2-1	North Valley	Sylmar	Sylmar	YES	1066.05	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	34.29058	-118.46406	PV1 MICRO INVERTER PLAN CHECK. TOTAL SYSTEM SIZE: 2.5KW. 10 MODULES AND ENPHASE MICROINVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7210	13041-10000-05102	15151 W TUBA ST	91345	7	204B145   396	2660017012	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.25643	-118.46265	PV1 ROOF MOUNTED SOLAR INSTALLATION ON 1 STORY BUILDING. SYSTEM SIZE IS 10.25 KW DC. 41 MODULES IN FOUR STRINGS USING TWO INVETERS. [MODULES TRINA SOLAR # TSM-250PA05.08 |||| INVERTERS: POWER-ONE # POWER-ONE-PV1-6000-OUTD-US (TRANSFORMERLESS) AND POWER-ONE # POWER-ONE-PV1-3.8-I-OUTD-S-US-NG (TRANSFORMERED) ]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7211	17041-10000-18456	7817 N WOODLEY AVE	91406	6	189B141   206	2205004043	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.21254	-118.48393	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7212	19041-10000-37729	510 S BROADWAY	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	08/18/2020 12:00:00 AM		Permit Finaled	02/26/2024 12:00:00 AM	ADDRESS	34.04767	-118.25088	TI IN AN EXISTING 5 STORY BUILDING WITH A NEW 2,000 AMP SERVICE WITH NEW ADDED LOAD AND RE-CONNECT TO EXISTING LOAD. EPC FOR POWER AND ENERGY. AFFECTED AREA: 7786 SQR FT.  BULDING PERMIT: 19016-10000-29084	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7213	14041-10000-13421	621 S WESTERN AVE # 208A	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TENANT IN COMMERCIAL SPACEPLAN CHECK FOR POWER AND ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7214	15041-20003-08466	9423 N RESEDA BLVD UNIT B	91324	12	198B125   467	2763035025	C2-1VL, P-1VL, RA-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.24178	-118.53643	Changes to approved set.  Adding seperate loose leaf sheets to main set of plans.  Restamp only - no permit to be pulled under this application number.PC FOR T24 ENERGY ONLY. THIS IS BARBER SHOP. LOW LOADS. NO DIM REQUIRED. LESS THAN .5W/SFNO POWER PC NEEDEDTHIS APP IS PC ONLY. PERMIT UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7215	15041-10000-40662	1160 S CALZONA ST	90023	14	118-5A227 176	5191004025	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.01932	-118.19625	PV1 INSTALL 3.72 KW DC SOLAR ARAY ON A SINGLE FAMILY HOUSE, (12) MODULES: CANADIAN SOLAR (10 INVERTER: SMA SB 3000-TL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7216	14041-20001-06173	4320 N VAN NUYS BLVD	91403	4	166-5A151 234	2266006051	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Apartment			03/06/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.14953	-118.44884	(((EXPEDITE FEES)))PV2 ROOFTOP FOR EXISTING APARTMENT BUILDIND. TOTAL SYSTEM SIZE 34.2KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7217	10041-20000-07681	1900 N MANDEVILLE CANYON ROAD	90049	11	135B137   102	4426011017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2010 12:00:00 AM	06/01/2010 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.06941	-118.49547	Plan check  for new 2 story single family dwelling with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7218	17041-10000-01309	1331 N CAHUENGA BLVD	90028	13	147A187   323	5546017014	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	09/02/2021 12:00:00 AM	ADDRESS	34.09556	-118.32924	PC for power and energy.  New 7 story mixed use apartment building with 3 levels of basement.  5 levels of apartment buildings over 2 levels of commercial.  369 apartment units, 28 transient (vacation rental) units, and 13 live work units.  New 4,000A service.  Total area = 313,900 sq. ft. Building permit #16010-10000-03279	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7219	18041-10000-24198	6360 W 80TH PL	90045	11	099B165   714	4108026034	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	33.96605	-118.39833	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES PV AND ESS INSTALLATION (UNDER 10002 SUPP.) WITH 20 MOUDULES, OPTIMIZERS AND CENTRAL INVERTER.PV SYSTEM SIZE 6.3KWDC/7.6KWACinspector to verify physical protection	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7220	10041-10000-11110	515 W 7TH ST	90014	9	129A209   147	5144004025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/11/2010 12:00:00 AM	07/21/2010 12:00:00 AM		Permit Finaled	11/24/2010 12:00:00 AM	ADDRESS	34.04704	-118.25593	New Restaurant. Plancheck is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7221	19041-10001-18326	15615 W CASTLEWOODS DR	91403	5	159B141   257	2280015017	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM			PC Approved	05/29/2019 12:00:00 AM	ADDRESS	34.13334	-118.47412	(EXPEDITE FEE)PC FOR PV-1. SCOPE OF WORK 54 MODULES (Q CELL Q.PEAK DUE-G5 315W) W/54 OPTIMIZERS (SOLAREDGE P320), 2 INVERTERS (SOLAREDGE SE10000H-US).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7222	19041-10000-41555	2600 S HOOVER ST	90007	9	123A201   122	5123001900	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	02/18/2022 12:00:00 AM	ADDRESS	34.03132	-118.2838	NEW FIRE ALARM SYSTEM WITH 120 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7223	15041-10000-09757	1222 E 25TH ST	90011	9	118-5A211 324	5119023014	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.01806	-118.25115	PV1, INSTALL ROOF-MOUNTED 4.90 KW DC SOLAR ARRAY, TIE WITH MAIN SERVICE PANEL. (15) MODULES  SUNPOWER SPR37NE-WHT-DAND (1) INVERTER POWER ONE PVI-4.2-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7224	12041-10000-17348	10833 W WILSHIRE BLVD	90024	5	132B153   252	4360003023	[Q]R5-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			07/25/2012 12:00:00 AM			PC Approved	07/25/2012 12:00:00 AM	ADDRESS	34.05971	-118.44117	Plan check for energy only.. 3538 sqft(3508 Outdoor). Pool area for an apartment and a restroom.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7225	14041-10000-34516	8019 N HASKELL AVE	91406	6	189B141    42	2206004011	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.21621	-118.47511	TI , T 24 repalcing fixtures one for one, emergency ligting is in place to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7226	13041-20000-01863	13447 W FILMORE ST	91331	7	210B157   857	2619014007	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.2689	-118.42585	Install new meter main 400 amperes to supply existing residential bungalow panelss, located in methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7227	13041-10000-24199	5421 W SANTA MONICA BLVD A	90029	13	144B193   700	5536010017	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1911.20	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.09092	-118.30761	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For retail suite A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7228	17041-10000-42574	862 S MAIN ST 2ND FL	90014	14	127-5A209 294	5145015002	[Q]C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	34.04148	-118.25466	ALTERATINS IN AN EXISTING OFFICE SPACEPLAN CHECK IS FOR TITE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7229	14041-10001-27211	1524 E COLON ST	90744	15	036B213   350	7426019017	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	33.79171	-118.24455	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7230	19041-10000-33784	15128 W BRAND BLVD	91345	7	210B145   169	2615003002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	10/26/2019 12:00:00 AM	ADDRESS	34.2716	-118.4612	Plan check for a PV1 3.8KW AC/ 3.4kw DC roofmounted system with (1) inverter, (12) modules and optimizer interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7231	13041-10001-36019	18770 W HILLSBORO ROAD	91326	12	207B121   482	2728029028	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.2637	-118.54196	Expedited RSES plan check per applicant request.{{PV1, Install 13.5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 5000A-US and Solaredge SE 6000A-US. (54) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7232	14041-10000-22972	2706 E MEDIA CENTER DR	90039	1	150B213  3657	5442032005	[Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	PIN	34.10723782	-118.24232865	TENANT IMPROVEMENT FOR A SINGLE FL WITH MEZZ  COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7233	16041-10000-31140	10250 W SANTA MONICA BLVD # 1903	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	08/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Johnny Was"" Ste. 1903.  Install new panel 200A, total effected area: 1,096 sq.ft, T-24 using Taylor method."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7234	16041-10000-08434	11115 N LAUREL CANYON BLVD	91340	7	210B149   706	2613025053	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM			Reviewed by Supervisor	03/22/2016 12:00:00 AM	ADDRESS	34.2721	-118.44668	PV2. NEW ROOF-MOUNTED SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 406KWac.(1951)MODULES-RENESOLA-RENESOLAR JC225-24/Bbh  (15)INVERTERS- ABB TRIO 20.0/27.6	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7235	19041-20000-32691	21820 W BURBANK BLVD Suite 240	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.17228	-118.6032	Plan check for Title 24 only in existing building Tenant Improvement office space. Total area: 5938 sq ft. B#19016-40000-23989	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7236	17041-10001-16063	10250 W SANTA MONICA BLVD #1460	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1st Revision to approved plan of retail space ""Peleton"".  SOW: revise power and lighting due to architectural (floor plan) change on the back of house area only.  This is plan check only, permit is covered on the master plan check."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7237	14041-10000-24512	911-915 E WASHINGTON BLVD	90015	1	124-5A203  21	5124017009	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM			PC Approved	10/02/2014 12:00:00 AM	PIN	34.03732889	-118.2779381	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM RETAIL TO OFFICE & TENANT IMPROVEMENT. NEWLY CONNECTED LOAD <400 AMPS. 4706 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7238	15041-10000-10240	1601 E 103RD ST unit-8	90002	15	091-5A213 176	6048013927	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	33.94385	-118.24586	Energy plan check for a commerical T.I ( Little Caesar) total area covers 1224-SQ feet. All lighting and branch circuits are new.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7239	16041-10000-12144	25481 S DODGE AVE UNIT #14	90710	15	036B197  1118	7413024***	(T)(Q)R3-1-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	33.79295	-118.28922	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. SOLAR SYSTEM IS FOR A 2-STORY W/BASEMENT GARAGE CONDOMINIUM-SINGLE FAMILY HOME. TOTAL SYSTEM SIZE IS 3.6KWac.(16)MODULES-KYOCERA #KU2606XPA(1)INVERTER-#PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7240	18041-20001-22790	19542 W VALERIO ST	91335	3	186B117   703	2116003066	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	06/28/2018 12:00:00 AM	ADDRESS	34.20423	-118.55936	06/28/2018 Changes to an approved set of plans. Roof layout has been revised.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 9.6 kWdc/8.6 kWac. System consists of (1) 10 kWac rated inverter and (32) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7241	15041-10000-10411	9246 N BALCOM AVE	91325	12	198B129   277	2766006007	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.23884	-118.52144	PV1, INSTALL NEW 13.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, TIE WITH MAIN SERVICE PANEL. (40) MODULES: SUNPOWER SPR-E20-327, (2) INVERTERS:SMA SB6000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7242	17041-10001-30687	1139 W 80TH ST	90044	8	099B197   658	6033020023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	ADDRESS	33.96658	-118.29544	Fee expedite per applicant<<New PV1 rooftop solar system with (2) AC Powerwall. (10) modules (1) 3kW AC inverter>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7243	10041-20000-19770	701 N STONE CANYON ROAD TEMP	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Closed	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	Plan check for installation of temp equipment supplied from existing 600A Temp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7244	11041-10000-25312	701 W CESAR E CHAVEZ AVE SUITE 101	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.06107	-118.24412	TENANT IMPROVEMENT FOR RETAIL PHARMACY W/ RACKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7245	16041-20000-27249	18771 W WILLOWTREE LANE	91326	12	207B121   529	2728029072	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Closed	01/26/2017 12:00:00 AM	ADDRESS	34.26304	-118.54197	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED10.2KW INTERCONNECTED WITH MSP.Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7246	17041-10001-23530	1210 S SOTO ST	90023	14	121-5A221 102	5170018018	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.10	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.02759	-118.21931	"*This is plan check only, permit is covered under master* PC FOR A TI TO AN EXISTING MCDONALDS FOR TITLE 24 ENRGY ONLY. INSTALLING NEW PANELS CIRCUITS LIGHTS AND EQUIPMENT.DELTA ""A"" Changes Only. TOTAL AFFECTED AREA 5889 SQ.FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7247	17041-10001-02863	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Closed	02/26/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGED NOTED DELTA 2 ON PLANS. CHANGE TO CIRCUITING LAYOUT. ADDED 12 CIRCUITS AND RELOCATED LOADS. UPDATED PANEL SCHEDULES. CHECKING FOR DELTA 2 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7248	13041-20000-23562	22323 W SHERMAN WAY	91303	3	183B101     6	2023028039	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Issued	09/12/2013 12:00:00 AM	ADDRESS	34.20119	-118.61272	T.I. TO (E) RESTAURANT. relocate lighitng for bathrooms. pc for t24 energy only. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7249	17041-10000-02489	770 W WILSHIRE BLVD	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM			Corrections Issued	01/25/2017 12:00:00 AM	ADDRESS	34.04914	-118.25811	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES ADDING ONE NEW ATS, REPLACING ELEVATOR LOADS, NEW CIRCUITS, AND REPLACING 3 ELEVATOR LIGHTS. TOTAL AFFECTED AREA IS 165 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7250	19041-10001-28297	14000 W TERRA BELLA ST	91331	6	201B153  1049	2642001002	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	34.24363	-118.43814	Plan check for a lost set of plans. Note: PC only((((PV 1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER. (19) MODULES AND (1) 7.8 KW INVERTER. TOTAL SYSTEM SIZE IS 7.0 KWAC/5.89 KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7251	18041-20000-14727	6324 N CANOGA AVE suite 200	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Issued	04/23/2018 12:00:00 AM	ADDRESS	34.18512	-118.59722	PC for T24 only for new lighting for office TI. Installing new lights in office and hallway.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7252	18041-20000-37117	10880 W WILSHIRE BLVD ste 300	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.05885	-118.44283	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7253	18041-20000-05510	1141 N MANSFIELD AVE Messanine	90038	4	144B181   360	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.09202	-118.34057	Plan check for Title 24 only. Project site is the mezzanine of an existing comercial building. Project scope is a tenant improvement. Total lighting area = 9,720 sq. ft.Note: Building permit has been issued under 17016-10000-27737	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7254	16041-10000-23223	44 W ST JAMES PARK 1-59	90007	1	123A201   127	5124024010	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.03122	-118.2807	INSTALL NEW INITIATING AND NOTIFICATION TO EXISTING FIRE ALARM PANEL.PLAN CHECK FOR 162 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7255	11041-20000-06312	17777 W VENTURA BLVD # 250	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	05/29/2012 12:00:00 AM	ADDRESS	34.16303	-118.51993	TI Unit # 250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7256	14041-20000-21509	3331 N BARHAM BLVD	90068	4	159B181   387	5579015006	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	34.13163	-118.34483	$0 permit fee due to senate bill 1222 from 2012PV2.  Install 39.0 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7257	13041-10000-12955	3550 S TROUSDALE PKWY	90089	9	118-5A201   9	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.02094	-118.28463	13041-10000-12955Ti, title 24 only library	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7258	17041-20000-45197	6150 N LAUREL CANYON BLVD Bldg H	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	07/09/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	Open air mall - Building H - 2-story addition, core and shell. New 34.5kV transformer and 4000A switchboard rated 277/480V 3ph 4w. T24 area: indoor-9,340sqft; outdoor-132,570sqft.  Plan check for power and energy. BUILDING PERMIT # 16014-10000-06045	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7259	17041-20000-34903	1985 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	Yes	2033.00	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Closed	03/24/2018 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of a temporary power installation. Work includes a medium voltage transformer. Temporary power will be in place while the permanent distribution equipment is being installed.Note: Permanent installation has been permitted under 15041-20000-02014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7260	17041-20001-17304	11979 W WALNUT LANE 1-4	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			08/04/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	34.03749	-118.4591	08/04/2017 Changes to an approved set of plans. Changes have been made to the outdoor egress lighting and the lighting fixture type in stairwells.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.  4 UNITS APARTMENT WITH 4 STORY OVER SUBTERRANEAN GARAGE.building permit # 15010-10000-02913	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7261	14041-20000-24015	10100 W SANTA MONICA BLVD 15th flr-suite 1500	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Info Complete	09/03/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	ti to an existing commercial building.  work to be performed on the 15th floor.  Addition of partitions in office spaces and new circuits to power existing lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7262	11041-20000-13971	10623 W BLOOMFIELD ST	91602	4	165B177   435	2423017018	[Q]R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.1497	-118.36223	POWER AND ENERGY. NEW 4 STORY 14 UNIT APT BLDG OVER FULLY SUB-PKG GARAGE WITH 1200A SERVICE. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7263	18041-20000-28166	6013 N MORELLA AVE	91606	2	177B169   753	2334016034	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.17995	-118.39009	PV1.  Reinstall 6.86 kW roof mounted grid tied PV system on fire-damaged SFD.  (28) modules with (2) 6 kW string inverters.  Originally permitted under 13041-20000-07939.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7264	16041-10001-35848	331-335 S BROADWAY	90013	14	130-5A211 111	5149015018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM			Reviewed by Supervisor	03/21/2017 12:00:00 AM	ADDRESS	34.05037	-118.24893	Full plan check. Changes to approved set of plans commercial building. Changes under delta 4. Changing feeder size and modifying electrical equipment labeled under delta 4. Also modifying emergency lighting, t-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7265	16041-20001-25541	10563 N AMBERWOOD LANE	91326	12	207B121   520	2728029081	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2016 12:00:00 AM			PC Approved	08/22/2016 12:00:00 AM	ADDRESS	34.2631	-118.54434	Modifications to approved set.  Changes to module layout on roof of SFD. $0 plan check fee due to State Senate Bill SB 1222(((Plan check for PV roof mounted system. System size: 11kW with 38 modules and 38 microinverters(Enphase 280))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7266	18041-10000-22726	1635 N NORTH MAIN ST	90012	1	136-5A217 150	5409003041	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.06681	-118.22858	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7267	13041-20000-08798	20653 W BASSETT ST	91306	3	183B109   703	2137026002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.19599	-118.58381	SOLAR SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7268	12041-10000-09576	6389 W 78TH ST	90045	11	102B165   837	4109003001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2012 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	ADDRESS	33.97188	-118.39987	New 8.46kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7269	14041-20000-04622	1965 N CANYON DR	90068	4	150A191    24	5586023032	R1-1-HPOZ	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Expired	05/05/2016 12:00:00 AM	ADDRESS	34.10715	-118.31711	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING 2 CENTRAL INVERTERS. TRANSFORMERLESS INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7270	10041-20000-12295	8252 N VAN NUYS BLVD CVS-FUTRE TENT	91402	6	192B149   400	2212004001	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.22127	-118.44856	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT TO 3000A SERVICE.  NEW PANELS AND REVISED LOAD. PLAN CHECK ALSO INCLUDE POWER AND ENERGY FOR FUTURE TENANT (8248 VAN NUYS BLVD.) WITHIN CVS (WILL REQUIRE COMPLETE PLAN CHECK) MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7271	18041-10000-06125	11944 W VALERIO ST	91605	2	186B165   543	2317015002	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Issued	02/20/2018 12:00:00 AM	ADDRESS	34.20472	-118.3943	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7272	14041-10000-35966	755 N LAUREL AVE	90046	5	141B177   294	5528007025	R1-1	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.0853	-118.36495	PV1 5.0kw roof mounted system with (1) solaredge SE5000A inverter, (18) LG Electronic LG305N1C modules and Solaredge power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7273	19041-10000-10253	4165 E CHEVY CHASE DR	90039	13	159B205   190	5593025901	OS-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	ADDRESS	34.13354	-118.26667	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7274	11041-10000-15799	2600 S MAIN ST	90011	9	120A205    44	5128001001	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	PIN	34.02451285	-118.26845494	T.I.  Existing 7-11 store.  Replacing 28 light fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7275	10041-10000-07711	1341 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			Corrections Issued	06/01/2010 12:00:00 AM	ADDRESS	34.05053	-118.22421	INSTALLATION OF A 2.82 KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7276	13041-10002-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			01/28/2016 12:00:00 AM			Reviewed by Supervisor	02/10/2016 12:00:00 AM	ADDRESS	34.10155	-118.31097	01/28/16Changes to an approve set of plans. Scope includes new lighting, receptacles, panels, and load equipment. estimate fees per applicant. Fees shall be verified. (((((DUE TO VALUE ENGINEERING TOTAL # OF CKTS REDUCED BY1759 CKTS , PALN CHECKED. WAS DONE ON APPLICATION # 13041-10001-36165 FOR VOLTAGE DROP CALS AND VALUE ENGINEERING.     M.ZANDI    9-16-2015    2-13-15  m.zandi..   addition of 50 branch circuits for basement circuitry  and title 24  percustomers information.)))))((   ORIGINAL SUBMITAL  ))New mixed-use 8-story, 280 unit apartment/retail over parking garage:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7277	18041-20001-35424	1431 N AVENIDA DE CORTEZ	90272		138B117   231	4431007026							Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			PC Approved	09/25/2018 12:00:00 AM	PIN	34.07336225	-118.56363151	Expedited plan check fee. PV1.  Install 8.25 kW DC/7.4 kW AC roof mounted grid tied PV system. (25) modules with 10 kW rated string inverter.  Derating of main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7278	16041-10000-01924	11260 W MISSISSIPPI AVE	90025	11	126B153   840	4260001069	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			01/20/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.03984	-118.44175	Full plan check for a New 3-story, 17-unit apartment building (1200A, 120/240V service) with roof deck over 1-level type I-A parking structure. Total area is 9305 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7279	10041-20000-16199	15232 W SATICOY ST	91405	6	186B145   181	2221001024	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.20826	-118.46507	PLAN CHECK T-24 ENERGY FOR CHANGE OF USE OF EXISTING RETAIL SPACE TO NEW SUBWAY TAKE-OUT RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7280	19041-20001-36656	10350 N NEWHOME AVE	91040	7	204B189   305	2560002023	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM			PC Approved	10/04/2019 12:00:00 AM	ADDRESS	34.2574	-118.32089	10/4/19CHANGES TO APPROVED SET DELTA 1 ONLY RELOCATION OF PV MODULES. <<<PLAN CHECK FOR NEW ROOF PV SYSTEM AND ENERGY STORAGE SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 7.56 KW DC/ 7.6KW AC. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER, (2) SUBPANELS, AND A 13.5KWH BATTERY.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7281	16041-20000-20369	5547 W SUNSET BLVD	90028	13	147A193    93	5544023024	C2-1	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.09826	-118.31107	Plan check Title 24 T.I. existing restaurant. Total area: 2,890 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7282	16041-10000-06432	4423 N BERGAMO DR	91436	5	165B137    74	2284015009	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.15188	-118.48709	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND OPTIMIZERS. (63) MODULES, (1) 3KW  INVERTER, AND  (1) 10KW INVERTER. TOTAL SIZE IS 13KW.Zero  permit fee pe CA Senate Bill 1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7283	16041-10000-20635	16237 W VENTURA BLVD	91436	5	168B137   349	2260010035	(Q)P-1, C2-1L, R3-1, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Info Complete	08/17/2017 12:00:00 AM	ADDRESS	34.15704	-118.48716	INSTALL (2) NEW NATURAL GAS FUEL CELLS IN A HOSPITAL BUILD. (OSHPD 3). FUEL CELLS LOCATED OUTSIDE OF BUILD. AND INTERCONNECTS WITH ELECTRICAL EQUIPMENTS LOCATED INSIDE THE BUILD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7284	13041-20000-24882	2716 S ELLENDALE PL E-J	90007	9	123B197  1480	5055013025	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.02988	-118.28859	Plan check for 600A service upgrade for NEW apartment building (building on 13041-20000-24879 is existing) . UnitsE, F, G, H, I, J only. Methane ZONE. Please check concurrently with 13041-20000- 24879 (service is on 13041-20000-24882 permit).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7285	18041-20000-21785	3551 S TROUSDALE PKWY suite 303	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.02066	-118.28531	Plan check for Title 24 Energy only in existing building USC ADM 3rd Floor Suite 303 T.I. Total area: 656 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7286	16041-10000-10741	2926 N GILROY ST	90039	13	150A211    87	5437030017	MR1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.10674	-118.25109	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES FOR A DANCE STUDIO. TOTAL AFFECTED AREA IS 3080 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7287	15041-10000-38355	2021 S FLOWER ST	90007	9	123A205    48	5126007008	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.03188	-118.27222	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7288	11041-10000-12037	695 S VERMONT AVE STE 500	90005	10	132B197   178	5094008026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	07/28/2011 12:00:00 AM		Permit Finaled	12/20/2011 12:00:00 AM	ADDRESS	34.06016	-118.29183	T.I.  NEW LIGHTING FIXTURE AND MODIFICATION TO THE POWER ON THE 5TH FLOOR OF A HIGH RISE OFFICE BUILDING.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7289	15041-20001-16302	936 S OLIVE ST UNIT 354	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #11 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7290	17041-20002-21338	3550 W WILSHIRE BLVD	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			PC Approved	09/21/2018 12:00:00 AM	ADDRESS	34.06157	-118.30226	09-21-2018 Changes to an approved set of plan, Changes include addtion disconnect(Circuit breaker)  ahead of performance meter. Changes has been clouded as dela. Plan check only, permit fee covered under Master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7291	18041-20000-25192	3826 N BENEDICT CANYON DR	91423	4	162B153   463	2272020036	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.14032	-118.43283	PV1.  Installation of 16.25 kW roof mounted grid tied PV system.  Installation of 400A residential service.   (50) modules with 11.4 and 3 kW rated string inverters.  Fees $17.93 Due to California Senate Bill 1222 and Assembly Bill 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7292	14041-20000-03781	11614 N HERRICK AVE	91340	7	213B157   313	2524019029	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.28132	-118.42541	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL. 4.75 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS, WITH (19) trina SOLAR #tsm-250pa05.18, (19) OP300-MV, (1) 5000A-US-ZB-U SOLAREDGE INVERTERS,	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7293	14041-10000-24585	8469 W MELROSE PL	90069	5	141B173   424	5528001055	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.08374	-118.37563	title 24 for a beauty solan. lighting and title 24 energy two story bldg	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7294	19041-10000-18662	1420 S ABBOT KINNEY BLVD	90291	11	108B145  1446	4238005040	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	33.99036	-118.46532	Energy PC (tailor method) for INTERIOR TI OF EXISTING RETAIL STORE. scope area 1,848sf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7295	15041-20000-43828	13701 N NORRIS AVE	91342	7	228B141   411	2603017009	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.31772	-118.47676	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM IS 7.02KWdc/6.0KWac.(26)MODULES-HYUNDAI HIS-S270RG(1)INVERTER-ABB PVI-6000-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7296	16041-20000-40390	11529 W STAGG ST	91605	6	189B169   607	2311011033	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Issued	11/21/2016 12:00:00 AM	ADDRESS	34.2126	-118.38282	Plan check for a PV1 roof-mounted PV system. System size is 18.6 kWac and consists of (54) AC modules and (1) load center.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7297	12041-10001-18719	8500 W BURTON WAY	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	DELTA 4 CHANGES TO THE APPROVED PLANS.     CONDITION WAIVED PER BEHZAD BY MEHDI 10/22/2012 (((((((((((((( cHANGES MADE TO PREVIOUSLY APPROVED SET, ADDITION OF 15HP  FIRE PUMP AND 3/4 HP JUCKY PUMP, CONVERSION OF TWO UNITS TO ONE PENT HOUSE, RELOCATING PANEL, LOAD CALS )))))))))))))))))(((((((((((( Revision to previously approved set , change of out door and indoor lits and title 24, new added ckts, relocation and reckting..  8-9-12  ))))))))))))))))))))))))New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7298	07041-10005-24502	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Apartment			12/30/2011 12:00:00 AM			PC Approved	12/30/2011 12:00:00 AM	ADDRESS	34.05562	-118.27458	(a) Revision delta 13 on E0.4 to change MI cable to 2-hour fire rated conductor (UL Category FHIT)(b) Revision delta 6 on E0.5 to increase feeder size with custom made MC cables with oversized equipment grounding conductor(c) Revision delta 10 on E1.0 to add reference note #1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7299	19041-20000-39166	7609 S MAIN ST	90003	9	099B201   134	6031013012	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	06/18/2021 12:00:00 AM	ADDRESS	33.97048	-118.27407	PV2. INSTALL 7.625 KW DC/6KW AC SYSTEM PV WITH (25) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7300	12041-20000-28362	19134 W ENADIA WAY	91335	3	183B121   239	2129003010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1325.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.20003	-118.55053	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7301	17041-20001-15139	15301 W VENTURA BLVD STE P-5	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.15411	-118.46654	"09/05/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 8. Changes have been made to the lighting floor plans and have been reflected onto the Title 24 compliance forms. Outdoor lighting is no longer a part of this scope of work.*****Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY.  TI TO (E) RESTAURANT SHELL WITH COVERED OUTDOOR DINING.  ""A"" OCCUPANCY LOAD > 100.  SUBPANELS TO REMAIN EXISTING.  NO CHANGE OF USE.  TOTAL AREA = 8499 SQ. FT.      BUILDING PERMIT #17016-10000-09902"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7302	11041-10000-09553	14708 W VENTURA BLVD	91403	5	166-5A149  67	2276002020	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.15154	-118.45347	"UPGARDING THE SERVICE TO 2000 AMPS FOR AN EXISTING 2 STORY BUILDING.  The HP is the only connected load.  Tenant loads, wiring, and panels are future, plan check is required.  The installation of future panels is subject to plan check.  The 150 ampere elevator circuit breaker on panel HP is to be fully rated for 100000 amperes.  Branch circuit breakers 100 amperes and less are series rated.  The panels shall be marked, "" Caution - Series Rated System, 95000 amperes available.  Identified replacement components required."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7303	16041-10004-15547	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	04/07/2017 CHANGES TO APPROVED SET. CHANGES ARE UNDER DELTA 25 AND 9. CHANGES INCLUDE ADDING NEW EQUPMENT TO EXISTING DISTRIBUTION BOARD, TITLE 24 CHANGES WITH ADDING RECEPTACLES AND LIGHTING. (((Package 5)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7304	11041-20000-23978	10889 W WILSHIRE BLVD	90024	5	132B153   290	4363022019	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM			PC Approved	11/09/2011 12:00:00 AM	ADDRESS	34.05908	-118.44352	T.I.  Museum.  Adding addtional lighting to the entirior and exterior of the facility.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7305	17041-10000-04332	1553 S ARMACOST AVE 1-6	90025	11	126B145   704	4263034017	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.04047	-118.45928	PC FOR NEW APARTMENT. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7306	16041-10000-38596	7720 N SEPULVEDA BLVD	91405	6	189B145   630	2209033035	C2-1VL, M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.2111	-118.46597	Remove HID fixtures and replace with new LED fixtures. Outdoor Title 24 only. Total sqft = 23700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7307	13041-10000-25564	10001 N GENESTA AVE	91325	12	204B133   624	2694009006	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.25255	-118.50419	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 9 KW DC ON STANDARD PLAN IN A SINGLE-STORY HOME.(36) MODULES: TRINASOLAR TSM-250PA05.18(1) INVERTER: FRONIUS #IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7308	16041-10000-41210	15220 W SHERMAN WAY	91405	6	183B145   101	2220001021	C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.20098	-118.4648	PC for title 24, outdoor. Remove HID fixtures and replace with new LED fixtures. Total sqft = 950.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7309	18041-20001-19630	15167 W NORDHOFF ST	91343	7	198B145   370	2656022001	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.23565	-118.46299	Revisions to approved set.  Change of service elevation diagram.  Approval for delta-1 modification only.  (((Plan check power only 800A  Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7310	17041-10001-17018	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.10229	-118.33907	"PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD CONDITIONS. SCOPE INCLUDES CHNGES TO LIGHTING CONTROLS ON FLOOR PLAN REMOVAL OF PHOTOCELLS, POWER PACK AND WALL SWITCHES FOR DISPLAY. FOR CHNGES UNDER DELTA ""E""THIS IS PLAN CHECK ONLY. !!!!Plan check for Title 24.  T.I. to retail/gallery/cafe space located on 2nd floor of (E) mixed use Hollywood & Highland Center.  Combine 5 tenant spaces into one (suites 213, 215, 217, 219, and 221).  Total area = 5,997 sq. ft.       Building permit #17016-10000-12799"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7311	14041-20000-07217	16233 W VANOWEN ST	91406	6	183B137   268	2224001901	M1-1, [Q]M1-1, [Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM			PC Info Complete	03/18/2015 12:00:00 AM	ADDRESS	34.19405	-118.48697	ELECTRICAL WORK IN VAN NUYS AIRPORT. NEW 600A DISTRIBUTION BOARD. FEES CALCULATED PER APPLICANT CALCULATIONS TO BE VERIFIED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7312	10041-20000-06772	11111 W SANTA MONICA BLVD #1470	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles			2673.00	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	05/04/2010 12:00:00 AM	ADDRESS	34.04771	-118.44481	energy plan check unit #1470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7313	19041-10001-08035	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM			PC Approved	04/19/2021 12:00:00 AM	ADDRESS	34.21499	-118.4422	Expedite per applicant request ((PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 3960 MODULES (Q-PEAK 395), 2040 OPTIMIZERS (P850 ) AND 10 INVERTERS ( SE 99.9K). SYSTEM SIZE IS 1000KWac AND 1564.2KWdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7314	11041-10000-12641	5169 W HOLLYWOOD BLVD	90027	13	148-5A195  81	5544011041	C2-1D	Central	Hollywood	Greater Griffith Park		1904.01	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM			PC Approved	06/17/2011 12:00:00 AM	ADDRESS	34.10189	-118.30279	TITLE 24 FOR AN EXISTING REMODELED RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7315	16041-10000-20659	12802 W FILMORE ST	91331	7	213B161  1025	2533029084	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.2788	-118.41155	PC FOR PV SYSTEM 4.09KW AC USING 19 MODULES AND USING MICROINVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7316	12041-20000-30344	444 S FLOWER ST 36TH FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	Change to lighting in the 36th floor corridor of an existing high rise office building.  Occupancy load is less than 99 and load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  <<Contractor is doing work on several floors, cumulative load over 400 amps will require Full Plan Check subject to field inspection.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7317	14041-20001-11203	6454 N BAIRD AVE	91335	3	180B125   568	2127010004	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	34.18828	-118.53745	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 7.5kW(2) SolarEdge #SE3800A-US-ZB-U transformerless inverters(30) Canadian Solar #CS6P-250PX pv modules(30) SolarEdge #P300-2NA4AZS power optimizers(1) Bryant #BR816L125RP 125Amp load center(3) New branch circuits]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7318	16041-10000-35848	331-335 S BROADWAY	90013	14	130-5A211 111	5149015018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.05037	-118.24893	FULL PC FOR POWER AND ENERGY. TI TO AN  (E)  2-STORY RETAIL  BUILDING. SCOPE INCLUDES A  NEW 1000A 277/480V 3 PHASE 4WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, NEW TRANSFORMERS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 32770 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7319	18041-20000-18954	7230 N VARNA AVE	91605	2	183B157    26	2328028030	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.202	-118.42457	Plan check for power and energy. Project site is an exising commercial building. Project scope is a service upgrade to 800 Amps/tenant improvement. Total lighting area = 935 sq. ft.Note: Service is feeding a separate building found on the lot. Tenant improvement for the building can be found under application number 18041-20000-18948.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7320	10041-10000-25281	4020 S MARLTON AVE	90008	8	114B185    92	5032002065	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.01159	-118.33819	Remodel theater.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7321	15041-20000-26776	5618 E MARMION WAY	90042	1	151-5A229 171	5468033024	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	PIN	34.1101604	-118.19429797	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel.(26) Sunpower 327W Modules(2) PVI 3.8 Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7322	16041-20000-09099	14822 W MAGNOLIA BLVD	91403	4	171A149    18	2263038006	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.1647	-118.45604	Plan check for Title 24 only. Project site is a new 6-unit apartment building. Service size is 400-amps. Total lighting area = 5,123 sq. ft.Note: Building permit has been issued under 15010-10000-02063	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7323	19041-10000-25403	1529 N KINGSLEY DR	90027	13	147A195    31	5544016024	RD1.5-1XL	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	04/03/2023 12:00:00 AM	ADDRESS	34.099	-118.30338	Plan check for a fire alarm system with (1) fire alarm panel, and (24) fire alarm devices located in a 3-story 4-unit apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7324	16041-20000-34277	3218 S BUTLER AVE	90066	11	120B157   895	4250020004	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.02166	-118.43137	pv1install roof mounted pv system sized 4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7325	13041-20000-31644	12910 W CULVER BLVD B & D	90066	11	105B157   578	4221031006	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	33.98314	-118.42695	Change to lighting in an existing low-rise office building.  Scope of work is in the restrooms only, Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7326	15041-10000-42791	300 S SANTA FE AVE	90013	14	129A217    74	5173013016	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM			PC Info Complete	02/11/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	PC FOR POWER AND ENERGY. FIRST TIME TENANT ART GALLERY RETAIL, TOTAL AREA 4847 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7327	12041-10000-16652	13466 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15935	-118.42656	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #12	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7328	15041-10000-00899	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"Plan check for T-24 only. Replace existing fluorescent light sign to LED. Retrofit existing fluorescent light sign to LED. sign with with new face Panel. Added new LED sing connect to existing power circuit. Refference Building Permit: 14048-10000-02684PROPOSED 3'-9"" X 4'-10"" D/F ILLUM. POLE SIGN (9-0)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7329	19041-20000-18496	10911 N SUNNY BRAE AVE	91311	12	210B109   293	2707025016	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.26849	-118.5807	install (1) tesla power wall ESS rated 5KW to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7330	16041-20000-21950	7947 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.21548	-118.53492	PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7331	13041-10000-33117	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	TI of right field team stores and concessions for Dodger Stadium.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7332	19041-20000-27608	600 W 7TH ST	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.04728	-118.25685	"relocation of existing ""PDU 3"" and addition of distribution board ""UPS-DP"".  plan check for power only."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7333	10041-10000-08460	115 E 23RD ST # 107-121	90011	9	121-5A207 116	5127028019	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM			PC Info Complete	08/23/2010 12:00:00 AM	ADDRESS	34.02714	-118.26646	New Core and shell for comercial building. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7334	19041-10002-36670	2581 E ARVIA ST #12	90065	1	145-5A217 517	5445031***	[Q]CM-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM			PC Approved	11/20/2019 12:00:00 AM	ADDRESS	34.09458	-118.23237	CHANGES TO APPROVED SET TO RELOCATE SE3800H-US PV INVERTER FROM OUTSIDE WALL TO INSIDE THE GARAGE. Plan check for a PV1  3.8KW AC / 4.9KW DC roof mounted system. Scope includes (1) inverter, (14) modules and optimizers interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7335	17041-10000-17221	810 E PICO BLVD B20, B21,-B22	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.03119	-118.25079	PC FOR TI . TITLE 24 ENERGY ONLY  REMOVAL OF INTERIOR PARTITIONS BETWEEN B20, B21, B22; TOTAL AFFECTED AREA OF 4000SQ.FTSOCPE INCLUDES NEW LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7336	16041-10001-40602	11120 W CHANDLER BLVD Build. 2	91601	2	171B173   257	2350015036	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			PC Approved	05/31/2018 12:00:00 AM	ADDRESS	34.168	-118.37317	PC FOR REVISIONS TO APPROVED SET UNDER DELTA 1,3,4 AND 5 AND 8.SCOPE INCLUDES REVISIONS TO LIGHTS POWER AND NOTES.  STORY MIXED USE, 106 RESIDENTIAL UNITS WITH 8-TYPICAL. PC FOR POWER AND ENERGY. NEW 2000A SERVICE  AND PRIVATE METER RESIDENTIAL UNITS. . TOTAL AREA INDOOR AND OUTDOOR: 122,538 SQ FT.B# 16010-10000-00103	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7337	18041-10000-31322	11111 W SANTA MONICA BLVD 16TH FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK FOR T24 ONLY, INTERIOR RENOVATION OF (E) RESTROOMS AND EXISITING ELEVATOR LOBBY, NEW LIGHT FIXTURES. NO CHANGE OF USE AREA OR OCCUPANCY. NO CHANGE IN FIRE LIFE SAFETY. TOTAL AREA UNDER THE SOW: 789 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7338	14041-10000-15044	3456 S MOTOR AVE UNIT C	90034	5	120B161   364	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.02698	-118.40853	T24 only. hair salon. total area 800 sq ft., plus permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7339	10041-10000-12779	500 W WORLD WAY MCP-09	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/03/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	04/08/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-09. This applicaation separates MCP-09 from the entire project on PCIS 09041-10001-24166( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7340	12041-10000-19104	10250 W SANTA MONICA BLVD A1	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	08/28/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	Plan check T24 Energy/emergency lighting for new Gucci retail space inside existing Bloomingdales .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7341	15041-20001-16320	936 S OLIVE ST UNIT 248	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #18 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7342	10041-10000-14467	4499 S GLENCOE AVE	90292	11	105B153   614	4212007008	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	09/01/2010 12:00:00 AM	ADDRESS	33.98486	-118.43595	TI in an existing office area. plan check is for title 24 energy cacls only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7343	11041-10000-21657	1800 CENTURY PARK EAST # 1100	90067										Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM				alterations throughout the 11th floor plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7344	15041-20000-00251	11755 W CULVER BLVD	90066	11	111B161   899	4233022070	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			01/06/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	33.99772	-118.41618	Plan check for power and energy. NEW 19-UNIT 3 STORY TYPE V-A   APARTMENT BUILDING. OVER TYPE I-A BASEMENT  PARKING GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7345	19041-10000-33857	862 N GALLOWAY ST	90272	11	126B129    79	4423027016	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.04497	-118.52047	(ePlan) PV1. PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING 16 AC MODULES (SOLARIA 355 WITH 1Q7-60 MICROINVERTERS) CONNECTED TO AN EXISTING 200A SERVICE. SYSTEM SIZE IS 3.84KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7346	16041-10001-35209	718 E JACKSON ST	90012	14	130-5A217 325	5173015006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/21/2016 12:00:00 AM	ADDRESS	34.0509	-118.23282	Changes to approved set. Removing storage and turning it into a hallway. for a single story health club studio. All changes are clouded under delta 3 and delta 4.  Total sqft = 6954.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7347	16041-10000-15022	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	TI on Terminal-2 IT rooms.  PC for Power and Energy.  Total area: 5,190 sq. ft. for 6 IT rooms. pc engineer to review fees. applicant has premade check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7348	15041-20000-36499	333 N KINGS ROAD	90048	5	138B173   283	5514010019	R1-1-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Issued	11/17/2015 12:00:00 AM	ADDRESS	34.07698	-118.37226	Plan check for PV roof mounted system. System size: 7.6kW and 26 modules. Standard plan is not being use.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7349	18041-20001-40070	4009 W MELROSE AVE	90029	13	141B197   435	5539020013	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.08371	-118.28728	expeditepv2install roof mounted pv system sized 57.6KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7350	15041-10000-28068	401 W WORLD WAY	90045	11	090B161    37	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	PIN	33.94317935	-118.40678881	Added exterior bench LED lighting to refurbished central terminal area for parking structure 4.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7351	17041-20001-42615	2016 N TALMADGE ST	90027	4	150B201   530	5591013001	R2-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.10814	-118.2829	12/20/2017 Changes to an approved set of plans. Changes have been made to reflect field conditions. *****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7352	12041-20000-26226	3715 S MCCLINTOCK AVE	90089	8	117B197     6	5039002034	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.02041	-118.29027	Plan check for fire alarm system. 2 panels and 36 devices. USC Doctor Cohen Basement Laboratory Remodel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7353	19041-10000-07171	6265 N SYLMAR AVENUE MALL	91401	6	178-5A151 179	2240003900	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.1842	-118.4467	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR) - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7354	16041-20000-43753	3124 N DIVISION ST	90065	1	150A217   287	5455003001	RD2-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.10442	-118.23265	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 100A MSP.3.6kW ungrounded system. (11) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7355	17041-20001-45589	14630 W SAN JOSE ST	91345	7	207B149   779	2648021019	OS-1XL-O, RA-1-O, RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.26122	-118.45094	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(40) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7356	10041-20000-08559	6733 N ETON AVE	91303	3	180B105    26	2148030034	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.1926	-118.59567	NEW SERVICE AND NEW TENENT FOR OFFICE AREA IN WAREHOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7357	11041-10000-23633	970 W 190TH ST st.810	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	12/02/2011 12:00:00 AM	ADDRESS	33.85812	-118.29302	T.I. to an existing office space.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7358	12041-20000-23785	3715 S MCCLINTOCK AVE	90089	8	117B197     6	5039002034	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.02041	-118.29027	Install new emergency generator to supply new and existing loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7359	17041-10000-34985	2646 E ZONAL AVE	90033	14	132A227    64	5202010032	RD1.5-1	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.05706	-118.19776	REPLACE HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7360	16041-20001-00530	13052 N DRONFIELD AVE	91342	7	222B153    31	2509020002	(Q)R3-1	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Apartment			02/15/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.30805	-118.43722	Revisions to approved set.  Delta-2 revisions only.  Relocation of power supplies; (1) PS omitted from system design.  (((PC FOR A NEW FIRE ALARM SYSTEM TO A NEW 3-STORY 44-UNIT APARTMENT BUILDING W/ BASEMENT GARAGE. SCOPE INCLUDES 118 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL, AND 1 COMMUNICATION PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7361	17041-10001-04504	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Info Complete	06/23/2017 12:00:00 AM	ADDRESS	34.05007	-118.2433	Changes to design.  Changes to single line diagram, Title 24, emergency lighting, and addition of new circuits.  Master application has outstanding corrections from M.Z. - Per supervisor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7362	11041-10002-04160	600 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	NEW CONVEYOR BELT SYSTEM FOR ALASKA AIRLINES, TERMINAL 6, LAX.  18 NEW PANALES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7363	11041-20000-19249	14950 W OXNARD ST	91411	4	177B145   472	2243022019	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM			PC Approved	09/15/2011 12:00:00 AM	ADDRESS	34.17917	-118.45903	PLAN CHECK T24 ENERGY TI FOR EXISTING AUTO BODY, RESTROOM AND NEW BREAKROOM AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7364	14041-20000-11274	10430 W WILSHIRE BLVD	90024	5	135B157   223	4326036***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			04/29/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.06564	-118.43046	New 800A service for electric vehicle charger station.  Plan check for power only.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
7365	14041-10000-33747	12515 W OSPREY LANE 1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	33.97893	-118.41131	Installation of (N) fire alarm system consisting of (50) initiating and notification devices in multifamily dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7366	17041-30000-36252	1307 N BRONSON AVE	90028	13	144B189    63	5545015023	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.09466	-118.31811	Plan check for fire alarm system n 21 units appartment 4 story. Total number of devices: 121 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7367	16041-20000-38323	12934 W VENICE BLVD	90066	11	111B153   935	4236012010	[Q]C2-1	West Los Angeles	Venice	Mar Vista, Venice		2738.00	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	33.99903	-118.44226	Plan check for Title 24 only. Project site is a new 2-story art studio. Project scope is lighting. Total lighting area = 11,197 sq. ft.Note: Building application has been generated under 16010-20000-00463	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7368	15041-20000-21551	11115 W MAGNOLIA BLVD	91601	2	171B173   534	2350018077	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.16506	-118.37299	Title 24 plan check only.  Total area = 5,072 sq. ft.  T.I. to existing commercial space.  New AC, plug loads, and lighting.  Less than 400 A new load being installed per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7369	18041-10000-11573	10281 W PICO BLVD 2-4 FLS-RESTRMS	90064	5	129B161   327	4315014059	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM			PC Approved	03/30/2018 12:00:00 AM	ADDRESS	34.0486	-118.41341	RELOCATE RESTROOMS @ 2ND, 3RD, & 4TH FLOORS OF (E) COMMERCIAL BLDG PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7370	16041-20000-18070	5670 W WILSHIRE BLVD 12th floor	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI to (E) commercial office space in (E) commercial highrise building.  Plan check for energy - 4187 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7371	16041-10000-44329	2029 S CENTURY PARK EAST #3150	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, PC FOR ENERGY ONLY. T.I TO AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 5085 SQ FT. B#16041-10000-44329	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7372	18041-10000-47275	1400 N CAHUENGA BLVD	90028	13	147A187   244	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	07/28/2021 12:00:00 AM	ADDRESS	34.09641	-118.32933	PLAN CHECK FOR FIRE ALARM PLAN CONSISTING OF 1 FIRE ALARM PANEL 592 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7373	18041-10000-36979	19259 W CASA PL	91356	3	171B117   456	2175002022	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM			Reviewed by Supervisor	10/05/2018 12:00:00 AM	ADDRESS	34.16232	-118.55394	PV1. NEW SOLAR SYSTME ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 20.74KWdc / 20.0KWac.(68)MODULES-HANWHA Q.PEAK-G4.1 305(68)OPTIMIZERS-P320(2)INVERTERS-SE10000H-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7374	10041-10000-04458	617 W 7TH ST	90017	9	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.04779	-118.2571	REMODEL 9TH FLOOR INTO OFFICES, FEW CLASSROOMS, TRAINING ROOM AND CONFERENCE ROOMS FOR THE Chicago School of Profession Psychology.   A variance to separate the electrical and fire life safety plan check and permts was submitted on April 22, 2010.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7375	13041-10001-27159	1207 S MALGREN AVE	90732	15	015B189   399	7560016012	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	33.73296	-118.31386	][][]EXPEDITED PER APPLICANT REQUEST [][][PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200 MAIN; WORK DONE ON A non-STANDARD PLAN.2 TOTAL STRINGS WITH OPTIMIZERS; DC UNGROUNDED, COMBINER BOX WILL BE USED; SYSTEM SIZE IS 7.75KW DC WITH (31) MODULES: TRINA #TSM-250PA05.18(1)SOLAREDGE #SE6000A-US(31)SOLAREDGE# OP250-LV-MC4SM-2NA-Z	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7376	16041-10002-33519	17361 W SUNSET BLVD	90272	11	126B117   614	4416003015	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.03993	-118.55459	PC for changes to approved set to reflect changes on the field. (Title 24  only)Scope includes new fixtures and new lights layout and some additional equipment. Additional  interior space of 352 sq.ft of patio enclosure under permit B# 16016-10002-22446	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7377	14041-20001-32518	17440 W NORDHOFF ST	91325	12	198B129   460	2768023018	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			PC Approved	11/29/2014 12:00:00 AM	ADDRESS	34.23567	-118.51484	expedite per customer request.pv1install roof mounted pv system sized 12.0kw interconnected with msp.(36) sunpower 327w modules(2) aurora 6k transformerless inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7378	08041-20001-27525	15600 W MULHOLLAND DR Phase 2	90077	5	159B145   570	4378001027	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	1416.00, 2622.00	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.12928	-118.47146	Plan check power and energy for changes to approved plans under permit # 08041-30000-27525. (Phase 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7379	11041-10001-26524	215 N ARDEN BLVD	90004	4	138B189  1434	5515011008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	ADDRESS	34.07504	-118.32613	Modification to approved plans to show correct location of main service panel and to remove additional AC disconnect.  Inverter is now located within sight of main service panel. Plan Check Only. <<<<New 6.6KW roof mounted photovoltaic system for a single family residence.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7380	17041-10000-22811	1834 S FIGUEROA ST	90015	9	124-5A205 180	5126009002	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Issued	09/20/2017 12:00:00 AM	ADDRESS	34.03477	-118.27157	PC FOR POWER AND ENERGY FOR AN 800A SERVICE UPGRADE. PLAN CHECK FOR POWER AND ENERGY FOR PLANT GROWTH. TOTAL AFFECTED AREA IS 1663 SQ. FT. B#17016-10000-17953	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7381	15041-20000-36605	12750 W RAYMER ST Unit 3	91605	2	186B161   550	2324004001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.20367	-118.40986	Plan check for Title 24 and Hazardous materials in room. Total area: 752 sqft. Note: Building permit # 15016-10000-19617	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7382	17041-20000-30147	7943 N WOODLEY AVE	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.21559	-118.48387	Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size is 960 kWac. Roof-mounted portion of the system is 780 kWac and consists of (13) inverters, (2274) modules, and (3) load centers.$0 permit fee due to State Senate Bill SB 1222.Note: Ground-mounted portion of the system has application number 17041-20000-30155 and has building application number 17010-30000-03240.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7383	17041-20000-41379	10316 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.25789	-118.5796	ti to an existing dental office.  adding new lighting new controls to existing panels.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7384	15041-20000-20071	16616 W DEARBORN ST	91343	12	198B137   809	2687025010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.23741	-118.49436	Plan check for PV roof mounted system. System size: 7.6kW with 27 modules and 1 inverter(7.6kW) Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7385	17041-10000-16861	2117 S SAWTELLE BLVD	90025	11	126B153   986	4260002029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.03895	-118.44217	Title 24 plan check.  T.I. to existing restaurant.  Existing subpanel to remain with new lighting and receptacles.  Total area = 1,750 sq. ft.         Partial Electrical permit pulled under #17041-20000-07102 (3 circuits)Building permit #17016-10000-00653	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7386	17041-20004-14437	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	"[[10/31/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 8 CHANGES CLOUDED. RELOCATING AC LOADS TOPANEL HA. PROVIDNG LOAD CALCULATION FOR DISTRIBUTION BOARD DBA]]]]10/23/2017changes to an approved set of plans.  changes noted delta 7.  changes include relocating existing equipment from distribution board ""DBA"" to house section ""MMH"".  no change in connected load.  this is plan check only.  10.18.2017 - Plan check for modifications to approved set. Update SLD to show actual connected load for conveyor system and panel MCP (400A). Update inverter to 10kW single phase 277V. Relocate equipment - panels 1LA, HA, HL, transformer T-LA, and inverter. Changes clouded delta 6.=======08/04/2017 Changes to an approved set of plans. All changes have been clouded and marked as Deltas 1, 2, and 5. Loads have been recircuited/relocated and there have been slight lighting changes.*****Previous Work Description*****Plan check for Power and energy wearhouse and office space T.I. new panels, lighting and receptacle. Total newly connected load exceed 400A feed from Existing 800A switch gear. Total area indoor lighting: 249,391 sq ft. B#17041-30000-04976"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7387	16041-10000-17692	7817 N LANKERSHIM BLVD	91605	6	189B169   659	2310025031	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Public Safety Only			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.21268	-118.388	FIRE WARNING SYSTEM FOR 2-STORIES MIXED USE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7388	15041-20002-36201	535 S KINGSLEY DR	90020	10	135B193   769	5503023019	P-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			04/19/2017 12:00:00 AM			PC Approved	04/19/2017 12:00:00 AM	ADDRESS	34.06428	-118.30317	4/19/2017Changes to an approved set of plans.  Changes noted delta 5 and 6.  revisions include aluminum feeders and energy calculations. This is plan check only.  (((PC for power and energy on a New 7-story, 72 unit apartment building over a podium parking level and 1 level of subterrean parking garage.  total area is 72,755 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7389	17041-10000-00520	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	TITLE 24 FOR TI FOR OFFICE  IN EXISTING SHEL SPACE  AT (TOM BRADLEY) LEVEL 3 AND  LEVEL 5.TOTAL AFFECTED AREA = 1015 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7390	13041-20000-15458	4824 N VINELAND AVE	91601	2	168B173   369	2421014001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Issued	09/11/2013 12:00:00 AM	ADDRESS	34.15833	-118.37007	RENOVATION OF INTERIOR OF EXISTING RESTARAUNT, PC FOR T24 ENERGY ONLY.  NEW CONNECTED LOAD LESS THEN 400A.   Occupancy load is less that 99 per building permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7391	18041-10000-19774	9522 S AVALON BLVD	90003	8	093A207   161	6050016005	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	33.94955	-118.26499	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7392	10041-10002-25281	4020 S MARLTON AVE	90008	8	114B185    92	5032002065	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Info Complete	06/08/2011 12:00:00 AM	ADDRESS	34.01159	-118.33819	CHANGES TO THE INTERIOR LIGHTING FIXTURES AND REDUCING EXTERIOR LIGHTING WATTTAGE FOR A  THEATRE.PLAN CHK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7393	10041-10000-05178	10445 W ASHTON AVE 1-3	90024	5	135B157   284	4326004021	[Q]R3-1	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			03/22/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	07/23/2010 12:00:00 AM	ADDRESS	34.06514	-118.42984	EPC for 3 units tri-plex residencial building.   Methane Zone.  No penetration below grade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7394	14041-20000-24847	10814 N HASKELL AVE	91344	12	207B141   172	2662020023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.26689	-118.47585	PV1.  Install 7.905 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7395	17041-20000-43986	23159 W BIGLER ST	91364	3	171B093   807	2074021017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.16076	-118.63125	PV1.  Install 10.2 kW roof mounted grid tied PV system.  (34) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7396	18041-10000-10117	340 N MADISON AVE	90004	13	138B197   117	5501002033	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Issued	07/19/2018 12:00:00 AM	ADDRESS	34.07748	-118.28901	INSTALLING SERVICE CONDUTORS FROM 800A 480/277V SECTION  ( 18041-10000-10111 new 2500A  service) TO SUPPLY EXISTING OFFICE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7397	15041-20000-23458	6316 N TOPANGA CANYON BLVD B-1620	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Closed	08/22/2018 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and Title-24 (energy).  Total area = 1,676 sq. ft.  T.I. to commercial first time tenant.  New electrical distribution for nail salon.  Lighting, recepticles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7398	14041-10000-11474	1820 S WESTMORELAND BLVD	90006	10	126B193   787	5074019010	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Apartment			04/30/2014 12:00:00 AM			Verifications in Progress	09/16/2014 12:00:00 AM	ADDRESS	34.04066	-118.30641	600AMP SERVICE UPGRADE FOR 5 UNIT APARTMENT BUILDING. NEW PANELS FOR ALL TENANTS AND COMPLETE REWIRE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7399	18041-10001-07471	1030 N SWARTHMORE AVE 2-107	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			Corrections Issued	08/23/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATION OF LIGHTING SYSTEM WITH MODIFICATIONS TO SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7400	17041-20002-19012	817 N VINE ST Bldg A	90038	13	141B185   173	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.0858	-118.32679	1/10/19changes to an approved set of plans. changes noted in delta 16. changes include removal of digital meters, update to fault current calc and load calcs, change from fully rated to series rating, addition of 1 outlet, and moving of equipment4/3/2018changes to an approved set of plans.  changes noted delta A.  changes include new inverter and associated circuits for EM lighitng and revisions to the energy calculations.  (((Plan check for power and energy. Renovation of existing office building (Bldg A) and addition of 1,500sqft mezzanine. Core and shell. Fed from new 3000A 480V 3ph-4W service. Methane zone.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7401	13041-20002-04317	8252 N VAN NUYS BLVD	91402	6	192B149   400	2212004001	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.22127	-118.44856	Modification to previously approved set of plans.  Change to receptacles, lighting.  New AC Units.         <<<<<Full plan check for power and energy. Fitness club.  CLUB IS OPEN TO THE PUBLIC 24 HOURS A DAY 365 DAYS A WEEK PER APPLICANT - No time clock required.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7402	19041-10000-35431	304 S BROADWAY #520	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	11/02/2019 12:00:00 AM	ADDRESS	34.05076	-118.248	Energy plan check for an office T.I located on the 5th floor of a commercial building. Scope includes new lighting and equipment with a total lighting area of 2010-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7403	15041-10000-16366	1230 S OLIVE ST	90015	14	126A207   209	5139024016	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Closed	08/17/2017 12:00:00 AM	ADDRESS	34.03857	-118.26278	TEMPORARY POWER FOR CONSTRUCTION OF A PARKING STRUCTURE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7404	15041-20000-20542	11524 W HUSTON ST	91601	2	168B169   195	2354012002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.15939	-118.38289	Plan check for a PV1 roof-mounted PV system. Plan check is for the addition of a 3 kWac system onto an existing 4 kWac system. Total system size is 7 kWac. System consists of (1) inverter, (12) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7405	16041-20001-16967	6922 W HOLLYWOOD BLVD #950	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			PC Approved	08/19/2016 12:00:00 AM	ADDRESS	34.10137	-118.34103	[[[ 8/19/16 CHANGES TO APPROVED SET. CHANGES TO T24 LIGHTING]]]Plan check Title 24 only in existing building T.I.. Total area: 2,806 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7406	19041-20000-07485	8760-8762 N BAIRD AVE	91324	12	195B125   632	2770017006	[T][Q]MR1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	02/26/2020 12:00:00 AM		Permit Finaled	01/09/2021 12:00:00 AM	ADDRESS	34.23043	-118.53722	New warehouse building.  600A 240/120V 3ph-4w service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7407	18041-20000-22129	515 S FLOWER ST 40TH&41ST-Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 Energy only in existing high rise building T.I. office space of 40th and 41st Floor. Total area: 15,442 sq ft. B#18016-10000-0761	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7408	16041-10000-36088	3722 W BOYCE AVE	90039	13	156A207   310	5435012025	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.12117	-118.26133	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 22275 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7409	13041-10000-24582	6780 W HOLLYWOOD BLVD	90028	13	148-5A185 157	5547012001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.10138	-118.33838	Installation of 296' red neon border and LED sign at Ripley's Believe-It-Or-Not.  Title 24 plan check only for sign lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7410	12041-10000-07617	938 W 28TH ST	90007	8	121-5A201  41	5123004405	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	11/02/2012 12:00:00 AM	ADDRESS	34.02867	-118.28345	"New 600A service, main panel and subpanels for an existing ""Fraternity House"".  Occupancy load is 34 people, per applicant.  Plan check for Power and Energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7411	11041-10000-25406	6150 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Public Safety Only			11/29/2011 12:00:00 AM			Corrections Issued	11/29/2011 12:00:00 AM	ADDRESS	33.94474	-118.39224	INSTALLATION OF A HEAT DETECTION SYSTEM AT THE RAYTHEON LAX DELTA HANGER ; ALARM FROM THE HEAT DETECTORS WILL INDICATE AT THE EXISTING BUILDING FIRE WARNING PANEL AND ACTIVATE A DELUGE SYSTEM   PERMIT ON 11041-10000-12266PLAN CHK WAS REQUESTED BY THE ELECTRICAL INSPECTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7412	13041-20000-29721	7252 N RESEDA BLVD	91335	3	186B125   911	2119020001	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.20267	-118.53589	T24 FOR EXISTING FISH STORE SPACE. PREPING IT FOR A NEW TENANT TO MOVE IN. PLAN CHECK FOR ENEGRY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7413	15041-20000-00707	3235 S HUTCHISON AVE	90034	10	123B169  1780	4312016040	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.03074	-118.38369	VARIANCE TO INSTALL PRIOR TO TEST LAB APPROVAL HAS BEEN FILED. Plan check for power and energy. Compliance with 2008 Title-24 due to building permit being submitted prior to July 1st, 2014. New 2-story type II-B Automated parking structure over traditianal surface parking. Remove existing service/transformer pad serving adjacent building, install a new 2000A (verify) service to feed new parking structure and adjacent building. Adjacent building to be fed from parking garage distribution equipment, client to install new transformer to feed existing distribution equipment in adjacent building. Fees calculated by applicant, adjust upon final.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7414	18041-20000-31725	6611 N RESEDA BLVD	91335	3	180B125   841	2126038901	(T)(Q)RAS4-1L-CDO-RIO, OS-1XL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			08/21/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	04/30/2021 12:00:00 AM	ADDRESS	34.19075	-118.53639	Fire alarm system for new 5-story 250-unit apartment building.  673 notification and signaling line devices with FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7415	10041-10000-00458	4031 W 3RD ST	90004	10	135B193   194	5518001015	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM			PC Approved	01/11/2010 12:00:00 AM	PIN	34.06919021	-118.30126686	TI AT THE YI PO RESTAURANTPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT  2 OF 3  (07044-10000-11944).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7416	11041-10001-06389	3659 E OLYMPIC BLVD	90023	14	118-5A227 191	5191008011	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM			PC Approved	10/31/2011 12:00:00 AM	ADDRESS	34.01901	-118.19844	Modification to previously approved set of T-24 and emergency lighting plans.   The changes involve location of swiches and some exit signs only.  No new lighting to be installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7417	15041-10000-28761	1925 S CENTURY PARK EAST STE 950	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24 TO AN (E) HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW 45KVA TRANSFORMER AND ADDITION OF A 125AMP PANEL AND NEW LIGHTING. TOTAL SQ. FT. 5676. PC FOR ENERY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7418	19041-10000-53456	384 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			Re-Activate Permit	05/13/2020 12:00:00 AM	ADDRESS	33.94339	-118.40887	Title 24 energy plan check. Scope of work includes adding 1 panelboard and circuits. Total affective area: 3,516 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7419	19041-20000-43481	18917 W CARMEL CREST DR	91356	3	162B121   158	2177048010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.14117	-118.54499	PV1.  Install 11.34 kW roof mounted grid tied PV system.  (36) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7420	15041-20000-30914	12636 W MATTESON AVE	90066	11	111B153   823	4235004009	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Apartment			09/18/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	33.99965	-118.43637	Plan check for power and Title-24 (energy).  Total area = 18,000 sq. ft. (indoor) + 3,930 sq. ft. (outdoor)      New 29 unit apartment building with 1,000 A service.  Plan checker to verify fees (applicant has pre-cut check from owner).  Fire alarm variance has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7421	10041-10000-22969	14565 W LANARK ST	91402	6	189B149    17	2210011030	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	09/27/2011 12:00:00 AM	ADDRESS	34.21805	-118.45109	NEW FIRE ALARM MONITORING SYSTEM. EPC IS FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7422	15041-20000-33584	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	33.98722	-118.47211	Plan check for Title 24 only. Project site is an existing commercial, high-rise building (6-story hotel). Project scope is a tenant improvement to the roof deck. Total indoor lighting area = 230 sq. ft. Total outdoor lighting area = 3,030 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7423	16041-30002-30707	535 S ALEXANDRIA AVE 1-106	90020	10	135B197   933	5502019017	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.06426	-118.2981	12/21/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. System is now interconnecting on the load-side instead of the line-side. *****Previous Work Description*****Plan check for roof-mounted solar array on apartment building. 38kW ungrounded system (7.6kW*5).(150) 340W pv modules. Each module has a 300W power optimizer. Interconnect with line side tap on 400A MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7424	15041-20000-16319	328 S LINCOLN BLVD	90291	11	111B145   668	4243016009	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.00096	-118.46664	Plan check for Title 24 only for T.I. in retail. Total area: 600 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7425	14041-20001-31394	20376 W VIA GALILEO	91326	12	219B113   161	2701044013	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.29559	-118.57795	EXPEDITE PER APPLICANT REQUEST[PV1Install roof-mounted solar array on a SFD. Interconnect with 300A MSP.System size: 10.2kW (3.6+3.6+3.0). Ungrounded system.51 255kW pv modules across 5 strings.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7426	17041-10000-25932	13630 W WILLARD ST	91402	6	189B157   147	2213019041	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.2175	-118.42943	PC FOR FA SYSTEM. FA system upgrade from (E) Simplexgrinnel to (N) Siemens XLS Fire Alarm system on (E) 2-story medical office building (Kaiser Permanente MOB)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7427	18041-20000-46962	17846 W LAHEY ST pv1	91344	12	210B129   246	2711021005	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.27319	-118.52318	pv1install roof mounted pv system sized 3.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7428	16041-10000-25327	660 S FIGUEROA ST # 1890	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Issued	07/21/2016 12:00:00 AM	ADDRESS	34.04953	-118.25947	Plan check for energy only to offices in suite 1890 for commercial building. Adding new lighting and power for receptacles. Total sqft = 1293. B#16041-10000-25327	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7429	13041-10000-00525	13770 W VAN NUYS BLVD	91331	7	204B153   282	2646001054	[T][Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.25774	-118.43321	Plan check for power and energy. New 1000 A service and electrical system for McDonald's restaurant. Location is in methane zone. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7430	14041-10002-08148	12411 W FIELDING CIR BLOCK 7	90094	11	105B161  1220	4211034054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/28/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	33.97968	-118.40871	**revision to the approved set of plan adding 19 devices and changing Horn's model type (((*revisionto the approved set of plan with adding less than 10 devices and removing some.<<<FA FOR APT. playa vista II - block 7. 5 buildings and 2 FACP. Permit to be split into 5 different applications per building? Plan checker to verify fee arrangment.>>>)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7431	16041-10000-22664	750 S GRAND AVE	90017	14	129A209   223	5144012058	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.04628	-118.25721	PC FOR ENERGY AND POWER. First time T.I. to (e) shell for a Wells Fargo Bank. SCOPE OF LOAD=400A. Total area 1707 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7432	18041-20001-24987	7219 W WARING AVE	90046	5	141B181   258	5525002038	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.08537	-118.34686	expedite per applicantpv2install roof mounted pv system sized 61.2kw AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7433	18041-10000-37897	777 S ALAMEDA ST 114	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	03/12/2021 12:00:00 AM	ADDRESS	34.03396	-118.24117	PLAN CHECK FOR POWER AND ENERGY FOR POWER AND ENERGY FOR - BLDG 1 TI FOR SUITE 114 OF 777 S ALAMEDA ST ; REMODEL OF THE BASEMENT AND 1ST FLOOR AREAS AND BUILD OUT OF A NEW KITCHEN AND STORAGEAREAS; ADD NEW TRELLIS ON NORTH SIDE - TOTAL AFFECTED AREA 3,586 SF WITH NEW CONNECTED LOAD OF APPROX 500A. ON EXISTING 1200A DISTRIBUTION BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7434	15041-10000-06683	8000 W SUNSET BLVD #B140	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.09783	-118.36466	Plan check for power and energy for a owner build out of a single space (AT&T store) created from one third area of the original core/shell space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7435	18041-10000-13599	1442 W 186TH ST	90248	15	060B193   226	6108012020	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	33.86187	-118.30111	Install New rooftop solar system on a (E) SFD, ssystem size 5.886 kW DC/ 5.208 kW AC. (18) AC modules (1) 100A load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7436	18041-10000-17986	4752 W 30TH ST	90016	10	120B181   314	5057023004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.0277	-118.3468	Plan check for PV1 roof mounted system with (12) Enphase IQ6-Pluc microinverter and (12) modules Trina Solar TSM-280-DD05A.08(II). Total System size is 3.36KWdc / 3.36KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7437	13041-10001-18310	1755 N HIGHLAND AVE	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.10323	-118.33897	Plan check for T24. Area(Outdoor+ Indoor lighting)10000 sq ft.Supplemental for application # 13041-10000-18310 per Mr. Zandi's request.(((Tenant renovation (lobby ) for high rise hotel. title 24 plan check only.10600sqft. permit to be issued at electrical plan check counter.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7438	18041-20000-39828	15600 W ODYSSEY DR	91344	12	213B145    23	2605002011	(Q)C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1092.00	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM			PC Info Complete	10/18/2018 12:00:00 AM	ADDRESS	34.28358	-118.47233	service upgrade 600 amps reconnect to existing loads. plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7439	17041-20000-36028	17801 W VENTURA BLVD	91316	5	171B129   290	2162012008	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Issued	10/06/2017 12:00:00 AM	ADDRESS	34.16317	-118.52051	ti to an existing commercial building restroom only.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7440	16041-10001-21845	400 W WESTMONT DR	90731	15	024B201   348	7412026017	[Q]M3-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM			PC Approved	08/10/2016 12:00:00 AM	ADDRESS	33.7641	-118.28532	EXPEDITEDRSES PLAN CHECK PER CUSTOMER REQUEST. (((PV2.  3.735 mega watts roof-mounted system with 13,005 modules, and 45 Delta inverter interconnecting through the utility transformer.))0	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7441	13041-10000-26932	1127 W WILSHIRE BLVD SUITE 1414	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.05287	-118.26415	TITLE 24 ENERGY PLAN CHECK ONLY. TENANT IMPROVEMENT FOR USC PERINATAL DEPARTMENT. ( MEDICAL BUILDING,NO SURGERY PER APPLICANT ) NO CHANGE IN OCCUPANCY. 2450 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7442	15041-10000-28404	1420 N DAVIES DR	90210	5	147B153   182	4357009017	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Expired	10/16/2017 12:00:00 AM	ADDRESS	34.09788	-118.43449	PV1, INSTALL NEW 41.6 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(160) MODULES: KYOCERA KU2606XPA(3) INVERTERS: FRONIUS SYRNO 12.0-3PERMIT FEE $0 BY STATE SENATE BILL#1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7443	10041-20000-14787	5855 N TOPANGA CANYON BLVD	91367	3	174B101    12	2146006011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	08/04/2010 12:00:00 AM	ADDRESS	34.17697	-118.60536	TI WORK IN A BANK. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7444	14041-20003-05183	4424 N BERGAMO DR	91436	5	165B137    59	2284016027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM			PC Approved	05/27/2014 12:00:00 AM	ADDRESS	34.15206	-118.48686	Changes from previously approved plans.  Relocate inveters and subpanel to roof top.  Permit is under the orignal application.Note: Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 18.9KWAC. (E) 600A SERVICENote: Permit fee is $00.00 due to Senate Bill 1222 from 2012.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7445	15041-10000-32842	4813 W OAKWOOD AVE (1-18)	90004	4	138B193   209	5522030010	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			10/05/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.07741	-118.31188	NEW FIRE ALARM SYSTEM ON A 4-STORY, 18 UNIT MULTI-FAMILY RESIDENTIAL BUILDING. THERE ARE 91 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL, 1 CONTROL PANEL, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7446	16041-20000-04197	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.14441	-118.39252	Plan check for a fire alarm system. Project site is an existing 5-story office building. Fire alarm system consists of (1) FACP, (1) anunciator, and (104) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7447	14041-20000-08948	23240 W SPIRES ST	91304	12	189B093   706	2020005043	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.2108	-118.63374	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7448	19041-10000-27462	6714 S MAIN ST	90003	9	102B205   231	6011003066	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	03/04/2021 12:00:00 AM		Issued	03/04/2021 12:00:00 AM	ADDRESS	33.97818	-118.27375	FULL PLAN CHECK FOR NEW  MIXED USE  AFFORDABLE HOUSING. SERVICE SIZE OF 2500 AMP, 208/120 3PH. SCOPE INCLUDES NEW 100KW BACKUP/STANDBY GENERATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7449	12041-10000-09199	3650 W MARTIN LUTHER KING, JR BLVD K-1A	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	"New ""Kiosk"" retail space at the Crenshaw Baldwin Hills Mall, shell only and a new 20A service to an exterior storage.   Tenant will submit application for modifications.  Plan check for Power only, no lighting."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7450	19041-20000-48740	6414 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.18736	-118.6425	T24 PLAN CHECK FOR LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 977 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7451	13041-20000-16989	8375 N LAUREL CANYON BLVD	91352	6	192B165   307	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.22391	-118.39926	UPGRADING (2) 2000A MAIN SWITCH BOARDS AND ALL THE FEEDERS FOR CANYON PLAZA SHOPPING CENTER. NO LOADS ARE BEING ADDED TO THE PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7452	12041-20001-08177	1051 N VISTAGRANDE DR	90272	11	132B121   422	4420025036	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.05606	-118.55074	single family and guest house are one building and service /swbd 800 A is in the same building and feeders to existing 200 A panels and 400 A panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7453	19041-20000-15921	1807 S MESA ST	90731	15	012B201   777	7456029028		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.72757	-118.28593	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR NEW SFD. SYSTEM SIZE IS 3.02KW DC/2.88KW AC. SCOPE OF WORK INCLUDES (9) SUNPOWER PV SYSTEMS WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7454	18041-10000-43970	2338 E 8TH ST	90021	14	123A217   319	5166008005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM			PC Info Complete	04/02/2019 12:00:00 AM	ADDRESS	34.02943	-118.2308	NEW COMMERICIAL OFFICES NEW 800AMP SERVICE. FULL PLAN CHECK INCLUDES POWER AND T-24. AREA OF SCOPE IS 8386.BUILDING PERMIT # 18016-10000-36472	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7455	19041-20000-03642	4425 N CANOGA AVE	91364	3	166-5A107 173	2190014022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.14993	-118.5957	Install 40.5 kWh energy storage system and load centers.  (E) 10.192 kW PV system on site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7456	18041-10000-40398	2236 W MERTON AVE	90041	14	162A221   199	5686021056	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.13784	-118.21571	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7457	09041-10001-20026	815 W COLORADO BLVD 1st Floor	90041	14	163-5A231 107	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM			PC Approved	06/24/2010 12:00:00 AM	ADDRESS	34.14051	-118.18382	Supplemental application T-24 Energy (general/emergency lighting) plan check for breakroom addition. Permit was issued under 09041-10000-17228.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7458	14041-20000-20424	6100 W WILSHIRE BLVD 16th floor	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.06282	-118.36187	Title 24 plan check only for an area of 498 SF containing 3 offices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7459	16041-10000-10383	435 N FLORES ST	90048	5	141B173  1300	5514003050	R1-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.07917	-118.3712	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.905KWac.(15)AC MODULES-SUNPOWER E20-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7460	18041-10000-44619	5524 N WILBUR AVE	91356	3	174B121   527	2161003002	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM			Corrections Issued	11/21/2018 12:00:00 AM	ADDRESS	34.17155	-118.54459	Plan check for T24 only, outdoor lighting on parking space, total area 10,904 sq.ftB# 18010-10000-05616	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7461	11041-10000-13443	4443 W SUNSET BLVD	90027	4	147A201   111	5542009015	C2-1D	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM			PC Approved	08/25/2011 12:00:00 AM	ADDRESS	34.0978	-118.28623	Install a new pv system on the roof of a commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7462	14041-10000-02877	221 E D ST	90744	15	030B209   862	7418012025	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	33.77442	-118.25995	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 17160 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7463	18041-10000-23117	450 S WESTERN AVE #203	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.06562	-118.30887	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. BEAUTY/NAIL SALON AND INTERIOR TENANT IMPROVEMENT.BUILDING PERMIT #18016-10000-13573	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7464	19041-10000-13730	20209 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM			PC Approved	07/16/2018 12:00:00 AM	ADDRESS	34.27509	-118.57388	FULL PC FOR WHOLE FOODS MARKET BUILDOUT (41,00SF) TO EXISTING CORE AND SHELL RETAIL BUILDING WITH 1 LEVEL MEZZANINE. SCOPE OF WORK INCLUDES NEW CIRCUITS AND PANELS. TOTAL SQ. FT. 42517.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7465	12041-20000-05870	2639 S LA CIENEGA BLVD	90034	10	123B173   546	5065006001	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM			PC Approved	05/25/2012 12:00:00 AM	ADDRESS	34.03407	-118.37726	remodelingEnergy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7466	15041-10000-20978	2827 S HOOVER ST	90007	9	121-5A201  45	5055028001	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	09/18/2023 12:00:00 AM	ADDRESS	34.02859	-118.28415	NEW FIRE ALARM SYSTEM 52 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7467	13041-20000-30178	12540 W BEATRICE ST	90066	11	105B161   993	4211005013	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	33.98119	-118.41413	T24 FOR EXISTING STUDIO. THIS IS NOT A THEATER. SCOPE OF WORK ON THE FIRST AND SECOND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7468	14041-20000-26590	19543 W SAN JOSE ST	91326	12	207B117   435	2708005020	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Expired	10/20/2016 12:00:00 AM	ADDRESS	34.26073	-118.55921	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECTED WITH MSP.(50) TRINA SOLAR TSM-255 MODULES(1) SOLAREDGE SE6000 INVERTER(1) SOLAREDGE SE 5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7469	11041-10000-19001	14812 W OXNARD ST	91411	2	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	09/28/2011 12:00:00 AM		Permit Finaled	10/21/2011 12:00:00 AM	ADDRESS	34.17923	-118.45564	NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7470	16041-20000-19815	4225 N ETHEL AVE 1-32	91604	2	165B161   875	2375016030	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			Reviewed by Supervisor	06/14/2016 12:00:00 AM	ADDRESS	34.14679	-118.41845	PV2.  Install 7.7 kW roof mounted PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7471	15041-20000-14858	18900 W WILLARD ST	91335	12	192B121   968	2104036023	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.21876	-118.54514	Plan check for a PV1 roof-mounted PV system. This application is for the addition of a 3 kWac system onto an existing and permitted 6 kWac system. The addition consists of (1) inverter, (12) modules, and (1) PV subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7472	14041-10001-33586	933 S WESTWOOD BLVD	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.06311	-118.44559	Changes to approved set.  Changes to lighting layout and fixture type.           Tenant improvement to (E) 3,234 sq. ft. commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7473	18041-20000-42062	5990 N SEPULVEDA BLVD #110	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.17911	-118.46588	Plan check for Title 24 only in existing space office T.I. Suite 110. Total area: 4043 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7474	15041-10001-12642	456 N FAIRFAX AVE	90036	5	141B177  1234	5527030025	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.07979	-118.36128	PC FOR POWER AND ENERGY. CHANGES TO AN APROVED SET OF PLAN. UPGRADING SERVICE FROM 400 TO 600AMP . TOTLAL AREA  REMAINS THE SAME, CHANGES FOR T24 IS CLOUDED IN NEW PLAN. THIS APPLICATION TO SERVE AS THE MASTER APPLICATION AND PERMIT. <<<TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1150.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7475	15041-20000-01907	1254 E 54TH ST	90011	9	108B209   557	5104015005	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	33.9938	-118.25296	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7476	19041-10000-21594	141 E JEFFERSON BLVD	90011	9	118-5A205 233	5120005003	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.01806	-118.27095	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7477	13041-10000-09374	2756 N WESTSHIRE DR	90068	4	156A191    75	5583015009	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2013 12:00:00 AM			Corrections Issued	04/11/2013 12:00:00 AM	ADDRESS	34.12066	-118.31974	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A 2 STORY SINGLE FAMILY DWELLING. SYSTEM SIZE IS 7.1 KW USING 33 MICROINVERTERS. [INVERTERS: ENPHASE ENERGY # M215-60-2LL-S22 |||| MODULES: SOLAR WORLD # SUNMODULE SW240 POLY]. FIRE DEPARTMENT HAS STAMPED A NON STANDARD ROOF PLAN DATED 4/11/13.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7478	17041-10000-19229	14001 W BURBANK BLVD	91401	2	174B153   690	2246030015	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.1723	-118.438	PC for T24 only for outddor lighting. Replacing 11 HID units for new LED fixtures. Total area of 39800 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7479	17041-20001-08270	22785 W CHARLEMONT PL	91364	3	165B097   433	2078004032	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	34.14775	-118.62358	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7480	11041-10000-13962	22100 W ERWIN ST	91367	3	177B101    79	2146003022	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Apartment			07/06/2011 12:00:00 AM			PC Approved	07/06/2011 12:00:00 AM	ADDRESS	34.18263	-118.60809	"TI TO AN EXISTING COMMON AREA IN AN APARTMENT BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.""Tenant Habitability Plan"" must be approved by the Housing Department before the permit is issued."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7481	16041-10000-11167	1911 W EL REY ROAD	90732	15	015B189    13	7559028024	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	33.74053	-118.31784	PV1, INSTALL 7.42 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(28) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-6000-OUTD-S-US-Z-ASTANDARD PLAN IS USED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7482	19041-10000-03994	10451 W SANTA MONICA BLVD	90025	5	132B157   742	4326032025	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.05657	-118.42598	TENANT IMPROVEMENT OF (E) RESTAURANT. INSTALL NEW LIGHTS. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-03060	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7483	19041-10001-34268	16641 W OLDHAM PL	91436	5	162B137    32	2291014022	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.14373	-118.49609	EXPEDITE FEESPV1, NEW ROOFTOP MOUNTED SYSETM, SYSTEM SIZE IS 14.6KWdc/10KWac. SCOPE OF WORK INCLUDES 40 MODULES (LG365Q1C) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE10000H-US), WITH AN EXISITING 400A MAIN PANEL AND A DERATE MAIN BREAKER TO 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7484	13041-20001-07661	13728 N DE FOE AVE Pv-1	91342	7	228B145   234	2603021014	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.3208	-118.47188	SUPP APPLICATION FOR CHANGE IN LOCATION OF SOLAR ARRAY. NO CHANGE IN ELECTRICAL PROPERTIES. PC ONLY. PERMIT ALREADY ISSUED UNDER ORIGINAL APPLICATION.Plan check for PV. Microinverter system. 5.375kW total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7485	17041-10000-04872	2121 S AVENUE OF THE STARS 33RD FLR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.05554	-118.41342	RESTROOM REMODEL. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7486	18041-30000-05286	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for power and energy at LAX Project 5 T2 Enabling(Termimal 2) New power and lighting added for new BHS(Baggage Handling System ) rearrangement of spaces at level 1. New power added  for power seating at level 3. Total area: 6,625 sq ft. B#18014-1000-00667	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7487	18041-20000-42383	11680 W BURBANK BLVD	91601	2	174B169   887	2350001017	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.17198	-118.38715	Plan check for power and energy. Project site is an existing commercial building/gas station. Project scope is a change of use from automobile repair to food market. Work includes a lighting area of 4,200 sq. ft. and intercepting existing loads (gas dispensers).Note: Building application has been generated under 18016-20000-31724	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7488	12041-20000-27795	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/18/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Existing retail space #18.  Modification being done to interior lighting.  Store is American Apparel.  Plan check is for energy only and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7489	13041-10000-04310	5644 W MANCHESTER AVE	90045	11	096B169   549	4125018014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	33.95967	-118.37993	DEMOLISH OF OLD BUILDING FOR NEW CONSTRUCTION. NEW CONSTRUCTION OF BURGER KING. RESTAURANT USE. TOTAL AREA OF 2340 SQ FT. PC FOR POWER AND ENERGY. changes on the plan include: no interior M panel (MSB is on the outside), panel A and B on the inside, roof access is (e), and no 240V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7490	16041-10000-04920	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.17307	-118.59314	Installation/ Addition to (E) Fire alarm system on Northrop Grumman Build. (1) FA Panels, (435) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7491	16041-20000-33620	4438 W DON MIGUEL DR	90008	8	114B181   725	5027003005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Issued	10/21/2016 12:00:00 AM	ADDRESS	34.00575	-118.35161	"""$0 permit fees due to senate bill 1222""PV1.  Install 15.2 kW AC (12.96 kW DC) roof mounted utility interactive PV system.  (54) modules with (2) 7.6 kW transformerless inverters with power optimizers."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7492	11041-20000-20987	6617 N FALLBROOK AVE #14	91307	3	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.19033	-118.62372	Existing retail space.  Remodel of interior light fixures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7493	13041-10000-32095	12468 N LONGACRE AVE	91344	12	219B125   123	2601075059	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.29631	-118.53624	PV1. PLAN CHECK FOR ROOF MOUNTED SOLAR ARRAY. POSTIVELY GROUNDED.  SYSTEM SIZE 13.8 KW.  40 MODULES SUNPOWER SPR-X21-345, (2) INVERTERS SUN POWER SPR-4000m & SPR-8000m) . (E) 400A MAIN. 100A LOAD CENTER WILL BE USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7494	13041-10000-34748	1925 S CENTURY PARK EAST STE 2350	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.06066	-118.41426	T24 PART 6 ENERGY FOR HIGH-RISE OFFICE BUILDING. TI WORK IS FOR LIGHTING RENOVATION TO 1471 SQ FT AREA OFFICES USING EXISTING NORMAL & EMERGENCY CKTS. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7495	13041-20000-04515	12630 N JIMENO AVE PV-1	91344	12	219B133   130	2602021017	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.29995	-118.50312	PV-1. Plan check for microinverter standard plan. 4.0kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7496	14041-10000-34313	11277 W DORA ST	91352	6	192B173   472	2632005013	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.22184	-118.37738	Plan check for Title 24 only. Scope of work is to remove HID light fixtures and replace with new LED fixtures. Total lighting area = 5130 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7497	14041-10005-15812	600 W WORLD WAY NORT	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	PIN	33.94461393	-118.39808495	SCOPE OF WORK INCLUDES THE ADDITION OF TWO NEW CIRCUITS, EXHAUST FANS ON THE ROOF AND MEZZANINE. NOTE CHANGES ON DELTA 1(((ADDITIONAL SCOPE OF WORK. PERMIT TO INCLUDE RENOVATION OF 2 RESTROOMS. PC FOR ADDITIONAL WORK DONE. REFERENCE TITLE 24 HAS BEEN INCLUDED. INSPECTOR VERIFY COPY OF ORIGINAL APPROVED SET. PERMIT TO BE ISSUED FOR ADDITIONAL WORK INVOLVED.ADDRESS HAS BEEN UPDATED TO MATCH PERMITS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7498	16041-20001-45427	21200 W TULSA ST	91311	12	207B105    81	2706031022	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.2674	-118.59483	expedite per applicantpv1addition to an existing system.install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7499	12041-20000-10741	617 W 7TH ST SUITE 400	90017	9	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.04779	-118.2571	TI for an office. Plan check for energy and emergency lighting. 13,136 condtioned sqft. Building is equipped with a generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7500	16041-30000-29487	2029 S CENTURY PARK EAST #500	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in  existing high-rise office High-rise. Total area: 2,734 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7501	19041-10000-37742	11234 N WHEATLAND AVE	91342	7	210B181    85	2550012005	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.27411	-118.35249	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KWac PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 36 MODULES USING P320 OPTIMIZERS.  $0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7502	18041-20000-48663	10920 W OAK MOUNTAIN PL pv1	91040	7	207B173   514	2528037022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.26266	-118.36793	pv1install roof mounted pv system sized 14.10KW DC, 12.6KW AC with 47 PV Modules and 2 inverters(5.0KW and 7.6KW) inerconnected with msp.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7503	13041-20001-23787	7021 N HAYVENHURST AVE	91406	6	183B137   212	2225003023	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.19818	-118.49259	T24 FOR EXISTING OFFICE SPACE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. TOTAL SQRFT 3465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7504	10041-10000-04053	448 S HILL ST #1006-#1012	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM			PC Info Complete	03/05/2010 12:00:00 AM	ADDRESS	34.04896	-118.25139	T.I. for a high rise building at 10th floor.  Install general lighting.  Plan check for energy only.  Branch circuits are under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7505	16041-10000-12546	7044 N TOPANGA CANYON BLVD	91303	3	183B101   258	2138002038	(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	PIN	34.19866562	-118.6054887	NEW RESTAURANT. NEW 120/208 3ph 4w, 600A SERVICE. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7506	19041-10000-36580	3807 S GRAND VIEW BLVD	90066	11	114B157  1475	4235023001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.00448	-118.43113	Energy plan check for a studio / storage T.I. Scope includes new lighting and equipment with total lighting area of 1430-SQ FT. Note. Portion of permit fee is paid under 19041-20000-32560.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7507	16041-20000-33666	6417 N TROOST AVE 4	91606	2	180B169  1088	2335010019	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Issued	10/07/2016 12:00:00 AM	ADDRESS	34.18726	-118.38677	pv2install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7508	18041-20001-30701	17893 W RIDGEWAY ROAD	91344	12	216B129   336	2601032037	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	ADDRESS	34.28515	-118.5242	Expedited plan check fee.PV1.  Install 7.50 kW DC/6.53 kW AC-CEC ground mounted grid tied PV system.  (25) modules with 6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7509	17041-20001-04897	307 S BROADWAY	90013	14	130-5A211  77	5149015026	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.05086	-118.24845	09/22/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the Title 24 and have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for energy only. Install new facade lighting on exterior of existing building. 7,278sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7510	15041-10000-20041	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.08469	-118.4849	PC FOR POWER. ST CHALON COLLEGE. ADDING TWO PUMP AND ONE UPGRADING CHILLER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7511	18041-10000-21400	1707 S WESTERN AVE	90006	10	126B193  1422	5073012033	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.04255	-118.30925	TI IN AN EXISTING COMMERCIAL AREA IN UNITS #1705 & 1707. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7512	17041-20000-28111	334 S CATALINA ST	90020	10	135B197   370	5502006023	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.06802	-118.29526	Plan check for a PV2 roof-mounted PV system. System size is 18.2 kWac and consists of (2) inverters, (66) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7513	15041-20000-34340	1515 W 190TH ST SUITE 518	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	33.85852	-118.30531	PLANCHECK FOR T24 ENERGY. REPLACE EXISTING FLUORESCENT FIXTURES WITH LEDS. 1090 SQFT. SUITE 518	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7514	19041-10000-23323	505 S VIRGIL AVE #206	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.0649	-118.28724	TI in an existing medicaloffice. Relocating exisisting lights. Full plan check for power & energy. No new loads added. Existing service, panel & circuits to remain. Plan Check Only.Permit Number: 18041-10000-47220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7515	14041-20000-02035	434 N LA BREA AVE	90036	5	141B181  1360	5525029025	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.07923	-118.34385	Change to lighting in an existing retail store.  Load is less than 400 amps.  Plan Check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7516	15041-10000-27753	2430 N ACHILLES DR	90046	4	153B173   462	5569028004	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.11525	-118.36863	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.6KW INTERCONNECTED WITH MSP.STANDARD PLAN CENTRAL STRING INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7517	17041-20000-43156	1440 N GORDON ST	90028	13	147A191   118	5545014045	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.09687	-118.31997	Plan check for a fire alarm system for a 4-story apartment building with 2 levels of below-ground parking garage. Fire alarm system consists of (1) FACP, (1) annunciator, and (110) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7518	17041-10000-08936	6600 N TOPANGA CANYON BLVD SUITE 2092	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR POWER AND ENERGY. T.I FOR A RETAIL STORE. CONNECTED LOAD . 400A . TOTAL AREA 8315 SQ FT. AREA CATEGOREY & TAILORED METHODB 17016-40000-06449	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7519	18041-20000-24983	10840 N SPRINGFIELD AVE	91326	12	207B121   123	2718012001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.26713	-118.54611	Plan check for PV roof mounted system, system size: 10.16kW AC CEC with 34 modules and 1 inverter(10kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7520	13041-10000-26103	380 WORLD WAY #T57-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of led sel-illuminated signs on the external walls of a the tenant space Bliss on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7521	12041-10000-11894	13912 W DAVENTRY ST	91331	7	207B153   375	2618004016	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	ADDRESS	34.26519	-118.43573	Plan check new roof mounted photovoltaic system 13.080kW single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7522	14041-10000-01746	1409 N LACHMAN LANE	90272	11	132B121    95	4420029021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.06018	-118.55033	PV1. ROOF MOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 8.64 KW DC(32) SOLARWORLD PLUS SW270 MONO(32) ENPHASE M215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7523	12041-10000-07578	10100 W SANTA MONICA BLVD 11th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM			PC Approved	04/20/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	T.I. to the 11th floor restrooms and elevator freight lobby of an existing office building.  Changing lights, 2 new receptacles.  Load is 6A  and occupancy is less than 99 occupants, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  (Full plan check may be required based on field inpsection)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7524	16041-10001-40347	17600 W RINALDI ST	91344	12	213B129   298	2711022004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.2792	-118.51781	EXPEDITD RSES PLAN CHECK PER APPLICANT REQUEST. <<<PV INSTALL NEW 12375 W DC ROOF-MOUNTED SOLAR ARRAY ON  A SINGLE FAMILY HOUSE.(45) MODULES: REC SOLAR REC275TP(2) INVERTERS: NINGO GINLONG TECHNOLOGIES SOLIS-3-6K-2G-US AND (1) 3K>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7525	14041-20000-05033	18753 W LULL ST	91335	3	186B121    65	2103017022	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			Corrections Issued	04/04/2014 12:00:00 AM	ADDRESS	34.20949	-118.5422	Roof mounted PV system with 4KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7526	17041-20000-46683	7509 N MADORA AVE	91306	3	186B113   377	2115012019	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.20634	-118.56629	Plan check for solar pv system w/roof-mounted array on SFD.5.98kW ungrounded system.(26) EnPhase IQ6-60 microinverters.(26) 305W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7527	19041-30000-14284	801 S FIGUEROA ST 11th Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the common area restrooms on the 11th floor. Project scope is a tenant improvement. Total lighting area  = 720 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7528	19041-20000-02512	534 N LA BREA AVE	90036	5	141B181  1005	5525020004	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			Corrections Issued	01/22/2019 12:00:00 AM	ADDRESS	34.08131	-118.34385	Lighting for (N) play deck and outdoor parking area.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7529	18041-20000-44663	9823 N OAKDALE AVE	91311	12	201B113   386	2761017017	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.24843	-118.56702	Plan check for PV roof mounted system, system size: 9.1kW with 28 with 1 inverter(7.6kW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7530	15041-10000-13824	8280 W MELROSE AVE	90048	5	141B173   480	5528013002	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	PIN	34.08342439	-118.36996343	RENOVATIONS IN BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7531	18041-10000-09282	8304 S RAYFORD DR	90045	11	096B157   318	4114032013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	33.96163	-118.42301	PC for 5kW(ac) rooftop system for SFD. Installing 16 modules (4.72kW(dc)), optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7532	12041-20000-06945	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.14246	-118.2705	New 800A subpanel.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7533	18041-10000-26183	20130 S WESTERN AVE	90501	15	054B193   700	7351021038	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.84871	-118.30902	PLAN CHECH FOR TITLE 24 ONLY FOR CHANGE OF EXISTING HID FIXTURES TO NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7534	10041-10000-17850	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM	01/03/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	New canopy and addition of passenger loading area. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7535	17041-20001-34188	6273 N OAKDALE AVE	91367	3	177B113    12	2153010002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	34.18457	-118.56505	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.210 KW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7536	14041-20000-05492	3419 N GLENDALE BLVD	90039	13	156B209   309	5435006003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.12058	-118.25844	PC FOR RELOCATION OF 600A SERVICE EQUIPMENT. PRVIDE NEW JBOX TO EXTEND EXISTING FEEDERS TO RECOONECT TO NEW LOCATION OF SERVICE. PC FOR POWER ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7537	12041-10000-23092	9155 N VALJEAN AVE	91343	12	198B137   829	2676018031	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	01/02/2013 12:00:00 AM	ADDRESS	34.23718	-118.48736	Plan check 5.232KW roof mounted photovoltaic system using SunPower transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7538	15041-10000-32895	1640-1640 S W SEPULVEDA BLVD 2ND FLOOR-WLA	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Issued	11/02/2015 12:00:00 AM	ADDRESS	33.8166	-118.30825	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE). SCOPE INCLUDES NEW LIGHTING AND ONE NEW PANEL. TOTAL AREA IS 11293 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7539	11041-10000-08259	8500 W BEVERLY BLVD #688	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	06/08/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	Ti for a retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7540	19041-30000-09213	16501 W VENTURA BLVD Suite 448	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.1578	-118.49275	Plan check for Title 24 only. Project site is a tenant suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,600 sq. ft.Note: Building permit has been issued under 18016-10000-34189	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7541	15041-20000-15791	1416 N RAVENNA AVE	90744	15	036B205  1043	7421026011	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	33.79154	-118.26871	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7542	11041-10000-27025	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	04/06/2012 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.04661	-118.2324	PROPOSED 6-STORIES MIXED USE BUILDING: RETAIL;APTS;LIVE/WORK UNITS;OFFICES;GARAGE;PORTION OF THE BUILDING IS 5-STORIES, TYPE IIIA, APTS OVER 1-STORY TYPE I GARAGE/RETAIL/OFFICE.OTHER PORTION IS 3-STORIES TYPE IIIA APTS OVER 3-STORIES TYPE INOTE; PRELIM SUBMITTAL PLAN CHK FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7543	15041-10000-35493	10250 W SANTA MONICA BLVD #169	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	T-24, CHANGE OF USE FROM RETAIL TO SHOWROOM FOR TESLA. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 297	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7544	18041-10000-43344	1541 W WILSHIRE BLVD #430	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.05529	-118.26949	INTERIOR OFFICE TENANT IMPROVEMENTS IN SUITE #430. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.BUILDING PERMIT: 18016-10000-36638	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7545	18041-20000-45165	225 S LINCOLN BLVD	90291	11	111B145   529	4240019061	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Reviewed by Supervisor	12/20/2018 12:00:00 AM	ADDRESS	34.00183	-118.46926	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Existing grocery store is being expanded. Total lighting area = 3,646 sq. ft.Note: Building application has been generated under 17016-30000-19434	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7546	10041-10000-15779	705 W 9TH ST unused-space	90017		129A207   265	5144021040							Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM			PC Approved	08/12/2010 12:00:00 AM	ADDRESS	34.04607	-118.2616	Electrical plan check for first time tenant in unused space on ground floor.  Existing permit # 10041-10000-08726, needs supplemental permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7547	19041-10002-34238	3379 N MANDEVILLE CANYON ROAD	90049	11	150B133   111	4491006010	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	09/18/2019 12:00:00 AM	ADDRESS	34.10464	-118.50377	EXPEDITED PLAN PLAN CHECK FOR ROOF MOUNTED 11.4 PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 43 MODULES USIGN P400 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7548	13041-20000-18294	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM			Corrections Issued	07/11/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	EXISTING MALL. NEW LIGHTING IN CANOPY AREA NEAR SEARS AND NEIMAN MARCUS. SOUTH WEST ENTRANCE. TOTAL AREA 1777 AND 245 SQ FT OF COLUMNS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7549	14041-20000-04090	13438 W CANTARA ST PV1	91402	6	192B157   829	2301004029	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.21974	-118.42613	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (N) UPGRADED MAIN SERVICE PANEL. UNGROUNDED SYSTEM, SIZED @ 6.5 kW DC, WITH (26) YINGLY YL250P MODULES, (1) COMBINER BOX, (1) POWER-ONE-PVI-6000-OUTD-US-A INVERTER WITH AFCI.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7550	11041-10000-19701	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	2951.01	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	33.77884	-118.29327	Install a variable freqency drive and 300 hp motor in a refinery with wiring passing through hazardous clasiffied areas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7551	19041-10000-10041	445 S FIGUEROA ST Ste. 2900-2940	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	Energy plan check for an office Tenant improvement located on the 29th floor of a high rise building; Scope of work includes new lighting and equipment with a total area of 6202-SQ FT.(Note: suites are 2900,2920,2940)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7552	18041-10000-30342	2410 N LILLYVALE AVE	90032	14	139-5A237 104	5220034025	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.07504	-118.16432	Power plan check for a 1600-Amp service switchboard replacement, service and load remain the same.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7553	17041-10002-04614	20179 W RINALDI ST BLDG A3	91326	12	213B113   266	2701004047	(T)C4-2D, A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.27523	-118.57313	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 25 & 28. CHANGES INCLUDE RELOCATING SITE LIGHTING, SPECIFYING EGC CONDUCTORS ON THE FLOOR PLANS,  AND REVISING PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7554	19041-20000-12027	777 S FIGUEROA ST 44th Floor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only. Project site is the 44th floor restrooms of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 750 sq. ft.Note: Building application has been generated under 19016-10000-08464	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7555	15041-20000-28861	9355 N REMICK AVE	91331	6	198B161   275	2629027023	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.23892	-118.41323	PLANCHECK FOR POWER. SERVICE UPGRADE TO 800 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7556	18041-10000-29087	8531 N FALLBROOK AVE FLR 1, 2	91304	12	192B097   582	2005022001	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Issued	09/13/2018 12:00:00 AM	ADDRESS	34.22425	-118.62931	Install New Fire Alarm system on (E) 2 story commercial building. (1) FACP, (252) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7557	16041-10000-07260	1163 N KENMORE AVE	90029	13	144B197   431	5540008012	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.09276	-118.2975	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.75KWac.(15)MODULES-LG LG310N1C-G4 310W(15)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7558	13041-20002-06945	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	09/18/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	changes to site lighting. changes clouded. plan check for t24 energy only site lighting. total area 62000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7559	15041-20000-35997	5547 E VIA MARISOL	90042	14	150A231   250	5301010016	RD1.5-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Expired	11/23/2017 12:00:00 AM	ADDRESS	34.10406	-118.18689	PV1, roof mounted solar panel, 3.42 kW(12) modules: SW 285 MOno(12) microinverters: Enphase M250Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7560	18041-20000-24438	5500 N LANKERSHIM BLVD	91601	2	174B173  1259	2350008058	C2-2D	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.17013	-118.37756	Tenant improvement of (E) commercial garage service area.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7561	18041-20002-31574	14630 W SATICOY ST	91405	6	186B149   219	2218003032	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM			PC Approved	05/17/2019 12:00:00 AM	ADDRESS	34.20831	-118.45189	$0 plan check fee due to SB1222 and AB1414plan check only, supplemental for changes to approved set. changes include racking and pv module model change. Change from (87) canadian solar pv modules to (82) longi solar pv modules. New system size is 28.29KW DC/22.8KW ACMinor changes to ALL pages due to pv module change.*original*PV2.  Install 28.275 kW roof mounted grid tied PV system.  (87) modules with (2) 11.4 kW rated string inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7562	18041-10000-48283	752 S OLIVE ST	90014	14	127-5A209  30	5144013027	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	PIN	34.04520471	-118.25648282	Energy plan check for a retail T.I. Scope includes new light and equipment with a total area of 1215-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7563	13041-20002-22442	11313 W WEDDINGTON ST	91601	2	171B173   290	2350016001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.16711	-118.3779	(((CHANGES MADE TO APPROVED SET OF PLANS. RECHECKING FULL T24.)))Change to lighting in an 2-story existing office building.  Load is less than 400 amps per the applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7564	12041-10000-15088	615 E 61ST ST	90001	9	105B205   522	6007006024	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			Reviewed by Supervisor	08/29/2012 12:00:00 AM	ADDRESS	33.98449	-118.26437	Plan check for new 15.67KW roof mounted photovoltaic system for an existing commercial building with multiple services. Photovoltaic system will be installed for each services under seperate application. (2 of 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7565	18041-20002-38477	18784 W TRIBUNE ST	91326	12	207B121   150	2717023026	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.26668	-118.54296	Revision to approved set.  Modification of MSP bussing and service disconnect configuration.  Note: $0.00 permit fee due to CA Senate Bill 1222.(((Plan check for a PV1 roof-mounted PV system. System size is 15.525 kWdc/13.967 kWac-CEC and consists of (45) modules, (45) micro-inverters, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7566	16041-10001-36486	3183 W WILSHIRE BLVD	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Issued	03/23/2018 12:00:00 AM	ADDRESS	34.06196	-118.29111	PC FOR POWER ONLY. SCOPE INCLUDES REPLACING TWO 75HP FIRE PUMPS AND TWO JOCKEY PUMPS FOR AN EXISTING EMERGENCY SYSTEM. NOTE: SOME FEES ARE COVERED UNDER PCIS# 16041-10000-36486	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7567	17041-20002-42738	3231 N STEVEN DR	91436	5	159B141   212	2293014019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Issued	02/28/2018 12:00:00 AM	ADDRESS	34.13339	-118.48222	Revisions to approved set.  Addition of 27 kWh ESS - (2) Tesla Powerwalls.  (((PV1.  Install roof mounted PV system sized 13.8kW interconnected with MSP.  (52) modules with 10kW and 3.8 kW rated string inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7568	11041-10000-00271	5054 S VERMONT AVE	90037	9	111B197  1346	5018018019	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM	01/06/2011 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	33.99673	-118.29133	New fire alarm control panel to connect to existing devices. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7569	19041-20000-25620	15941 W ARMINTA ST	91406	6	189B141   128	2206007046	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.21399	-118.4807	POWER AND ENERGY PLAN CHECK FOR TI TO EXISTING COMMERCIAL WAREHOUSE. T24 INCLUDED TOTAL SQUARE FOOTAGE = 10,335 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7570	11041-20000-05180	6633 N FALLBROOK AVE	91307	3	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	03/16/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.19044	-118.62372	replace 5000 Amps bussduct with same manufactrur 27 feet damaged by water	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7571	13041-20000-19527	17031 W SEPTO ST	91325	12	201B133    27	2694008014	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.25131	-118.50351	PV1 MICROINVERTER. TOTAL SYSTEM SIZE: 6.85KW. 31 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7572	15041-20000-31569	1457 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.09731	-118.31598	Plan check for power and energy. TI to existing  commercial building (5 floors). not a highrise per applicant.  Total sqft. 14,228.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7573	14041-20000-27498	4222 N VINELAND AVE	91602	2	165B173  1260	2366020002	[Q]C2-2D	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.03	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.1455	-118.37004	Tenant Improvement to existing Restaurant. Plan check for place of assembly, greater than 100 occupant load per applicant.  Power and energy.Note: Variance to separate fire alarm plans submitted on 11/19/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7574	15041-20000-06207	500 S PACIFIC AVE	90731	15	015B197   208	7455004019	[Q]C2-1XL-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.73944	-118.28772	energy plan check storage room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7575	19041-20000-15528	2131 S SELBY AVE	90025	5	129B157  1303	4321013043	R1-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.046	-118.42966	Plan check for a PV1 roof-mounted PV system. System size is 7.2 kWdc/6.4 kWac and consists of (20) micro-inverters, (20) modules, and (2) load centers. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7576	14041-20000-24522	10973 W PENROSE ST	91352	6	195B173   258	2408028015	[T][Q]CM-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.23042	-118.37016	New commercial building - core & shell.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7577	18041-10002-03772	5621 W BOWCROFT ST	90016	10	117B173    67	5025005025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	34.02026	-118.36784	Supplemental plan check for revisions to approved set. Changing main panel rating from 100A to 200A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7578	18041-10000-38031	1011 W FRANCISCO ST	90502	15	057B197    59	7351034052	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	33.84994	-118.29407	REMOVE OUTDOOR HID FIXTRES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7579	19041-20001-51088	2139 N UPPER KRESS ST	90046	4	151-5A173 166	5567002013	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.10972	-118.37781	Expedite per applicant request. Plan check for PV roof mounted system, PV system size: 15.48KW with 43 PV Modules and 2 inverters(7.7KW) connnected to existing 200A Service. Owner Builder.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7580	14041-20001-31649	10648 N MELVIN AVE	91326	12	207B117   275	2708005009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM			PC Approved	12/02/2014 12:00:00 AM	ADDRESS	34.26383	-118.55992	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECT WITH MSP.(44) LG MONOX MODULES(44) ENPHASE M250 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7581	19041-10000-05046	6151 N RADFORD AVE parking-Bldg B	91606	2	177B165  1102	2334011031		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	03/03/2023 12:00:00 AM	ADDRESS	34.18246	-118.3924	"FULL PC FOR BLDG B PARKING STRUCTURE TO SUPPORT BLDG ""B"" RESIDENTIAL APARTMENT BUILDING:  NEW 7 STORY  PARKING STRUCTURE WITH MAINTENANCE ROOM AND ROOF-TOP POOL AMENITY SPACE.  SCOPE OF WORK 297,083 SQFT. 2000A 480/277V 3PH 4W DIST. BOARD SUPPLIED FROM THE RESIDENTIAL STRUCTURE SERVICE EQUIPMENT.(B# 19010-10000-00593)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7582	16041-10000-45544	22320 W JAMES ALAN CIR	91311	12	204B101    68	2723008***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.25888	-118.61193	PV, INSTALATION OF 7.124 KW AC ROOF-MOUNTED SOLAR ARRAY ON A TOWN HOME APARTMENT.(26) MODULES: Q-CELL Q PLUSL-G4.2 330(13) MICROINVERTES: APS YC500I	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7583	18041-10000-33395	15414 W CHATSWORTH ST	91345	7	207B145   323	2649012002	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Issued	08/31/2018 12:00:00 AM	ADDRESS	34.26433	-118.46811	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7584	11041-20000-18096	10940 W WILSHIRE BLVD	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.05822	-118.4452	Ti in an existing office. EPC is for T24 & emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7585	18041-30000-32305	1832 S BARRINGTON AVE	90025	11	126B149   960	4262021095	RD1.5-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Apartment			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.03921	-118.45191	PC FOR NEW FA FOR 4 STORY 11 UNITS APARTMENT BUILDING. TOTAL DEVICE COUNT 74 WITH 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7586	18041-20000-36328	20818 W SPRUCE CIR	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.29508	-118.58812	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7587	19041-10000-37585	1875 S CENTURY PARK EAST STE 850	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.06115	-118.41457	TENANT IMPROVEMENT IN AN EXISTING COMMERCIAL OFFICE IN SUITE #850.INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 6850 SQR FT.BULDING PERMIT: 19016-10000-28081	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7588	16041-10000-45125	5001 W RODEO ROAD STADIUM	90018	10	120B181   948	5046013900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	05/06/2020 12:00:00 AM		Permit Finaled	09/30/2022 12:00:00 AM	PIN	34.02302534	-118.35149882	PC FOR POWER AND ENERGY. CONSTRUCTION OF SPORTS ARENA, MAI SWITCHGEAR IS 200A. TOTAL AREA 5119 SQ FT.B # 16010-100000-03060	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7589	17041-10000-34035	13327 W MOORPARK ST	91423	4	165B157   295	2360013024	[Q]C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.1505	-118.42342	PC FOR MEDICAL OFFICE TI. (DENTAL) CHANGE OF USE FROM RESTAURANT TO MEDICAL OFFICEFOR POWER AND ENERGY. SCOPE INCLUDES NEW PANELS CIRCUITS LIGHTS AND RECEPTACLE. TOTAL AFFECTED AREA 2150 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7590	15041-10000-18752	5698 S GOLDENEYE CT 1-3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	33.9792	-118.41068	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'B'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'B' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7591	19041-10002-07098	15815 W MONTE ST #105-#106	91342	7	225B141  1525	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Issued	06/28/2019 12:00:00 AM	ADDRESS	34.31113	-118.47563	suplemental permit for 19041-20000-07098 to revise floor plan and create storage (H-2 occupancy). Note: Building permit has been issued under 18016-20001-05898	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7592	18041-10001-32591	1438 W 254TH ST	90710	15	036B193   526	7410006044	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			PC Approved	10/02/2018 12:00:00 AM	ADDRESS	33.79368	-118.30248	EXPEDITED PER APPLICANTS REQUEST.PV2. 2.1 KW ROOFMOUNTED SOLAR SYSTEM. + 13.5 KWH ENERGY STORAGE DEVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7593	15041-20000-39997	6858 N MAMMOTH AVE	91405	2	183B157   787	2216025051	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.19551	-118.43221	PV2. Install roof mounted PV system sized 13 kW. Interconnectd with main service panel.(40) SunPower 327W Modules(2) SMA inverters: SMA 7.7 and SMA 3.8	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7594	19041-20001-36662	22111 W ERWIN ST	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18299	-118.60932	Expedite per applicant request. Plan check for Pv roof mounted system, PV system size: 27.84KW DC, 24.8KW AC CEC with 64 PV Modules and 2 inverters(14.4KW and 9.0KW)Applicant reques: %%%%%%%%%%      Plan stay Van Nuys    %%%%%%%Note: This is 12 Buildings on 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7595	18041-20000-48665	9825 N WISH AVE pv1	91325	12	201B133   220	2692014009	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.24918	-118.508	pv1install roof mounted pv system sized 18.56KW DC. 16KW AC with 58 PV Modules and 2 inverters(10.0kW and 6.0KW) interconnected with msp.Fess $0.00 due to california Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7596	15041-20000-36372	4334 N STERN AVE	91423	4	165B153   402	2271016058	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.1495	-118.43535	Plan check for power only. Project site is an existing apartment building (31 units). Project scope is the replacement of electrical service distribution equipment and unit panels: (1) 400-amp section, (1) 600-amp section, and (18) 60-amp panels. Approved for counter plan check by E.M.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7597	16041-10003-16755	8250 N WOODMAN AVE	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM	ADDRESS	34.22107	-118.43251	Plan check for restamping a lost set of plan. ((($0 permit fee due to senate bill 1222 from 2012Installation of new roof mounted solar PV array on existing Kaiser Foundation medical office building.  Total system size = 317 kWac.  11 SCA23KTL inverters, 1 SCA28KTL inverter, and 1 SCA36KTL inverter.  1,240 Hyundai HIS-S325TI modules.  Supply side tap used.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7598	14041-20001-32559	17624 W VINCENNES ST	91325	12	198B129   159	2766001027	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.2408	-118.51875	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main breaker to 175A.System size: 10kW (5+5). Ungrounded system.44 255W pv modules across 4 strings (inv 1: 10+10; inv 2: 12+12).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7599	18041-30000-29816	2029 S CENTURY PARK EAST 23&24 FL	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Install 161 additional device on (E) FACP. These new devices are installed on 23rd and 24th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7600	16041-20000-44242	14547 W TITUS ST	91402	6	192B149   494	2210010031	[Q]CR-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.21986	-118.45017	remove existing hid fixtures and replace with new led fixtures. plan chech for energy outdoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7601	16041-20000-30809	18219 W PARTHENIA ST	91325	12	195B125   789	2769021021	R1-1, [Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.22881	-118.53024	TI TO AN EXISTING COMMERCIAL BUILDING REPLACE VEHICLE DAMAGE TO STORE FRONT.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.TOTAL SQUARE FOOTAGE 5040.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7602	18041-10001-06626	11193 N DE HAVEN AVE	91331	7	210B161   249	2533014008	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.27366	-118.41336	Changes to an approved set PC only. Relocating two modules position only. Changes are marked under delta 4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7603	10041-10001-21655	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM			PC Approved	05/24/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	MODIFICATIONS TO AN EXISTING APPROVED SET OF PLANS. Delta4 shows all  the changes<<<<<<<<<<<<<<<<<<<< exterior common area, mall common area and food court renovation include new tile floors, new paint, new children's play area, re-design food court, new food commissary, new performance stage, new food kiosks, new restrooms, upgrade building entrances, new mall management office. EPC is for power and energy >>>>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7604	15041-10000-07066	200 WORLD WAY # 223	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR ENERGY. INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM  ROW. TOTAL AREA  47.291 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7605	16041-10000-13013	1629 W LINDA ROSA AVE	90041	14	160-5A225 115	5689013013	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.13522	-118.2025	PV1, rooftop solar 7.7 kW AC      (26) SPR327NE-WHT        (1) SB7700TL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7606	19041-10000-14944	17263 W VANOWEN ST	91406	6	183B133   936	2230001012	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			Reviewed by Supervisor	05/09/2019 12:00:00 AM	ADDRESS	34.19403	-118.5093	PV2 roof mounter system, size is 39.6KWdc/38.5KWac. Scope of work includes 120 modules (Candian Solar CS6U-330P), 5 inverters (Sunny Boy SB-7.7 -1SP-US-40) , 200 A combiner panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7607	13041-10001-28798	19028 W FRIAR ST	91335	3	177B121    34	2128007005	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.18555	-118.54788	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE : 3.5KW. TRANSFORMERLESS UNGROUNDED.(14) HANWHA #HSL60P6(1) SOLAREDGE # SE 3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7608	13041-10001-18525	6081 W CENTER DR #113-119	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Info Complete	10/28/2013 12:00:00 AM	ADDRESS	33.97811	-118.39245	PANEL CHANGE IN DWP ROOM, RELOCATING LOADS TO EXISTING PANEL . FEEDERS FOR FUTURE TENANT. SERVICE SIZED OVER 1600A, SECTION SIZE 1600A. APPROVAL PENDING UTILITY 12 MONTH PEAK READING.Changes made to primary approved set.Meeting with Bruce on 10-22-13, with Romeo on 10-23-13 to revise loads and single line correction issues.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7609	18041-20001-34652	14013 W REMINGTON ST	91331	6	201B153   838	2644009005	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM			PC Approved	09/18/2018 12:00:00 AM	ADDRESS	34.24482	-118.43857	CHANGES TO APPROVED SET, CHANGE SERVICE SIZE FROM 200A TO 400A$0 PC FEE PER STATE SENATE BILL 1222 AS AMENDED AND EXTENDED BY STATE ASSEMBLY BILL 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7610	19041-20000-06545	21650 W OXNARD ST SUITE 2360	91367	3	177B105    83	2146006042	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only in existing space Tenant Improvement new lighting. Total area: 2584 sq ft. B#19016-10000-03853	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7611	18041-10001-09744	1816 N VERMONT AVE STE1/2&3/4	90027	4	150B197  1082	5590020002	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM			PC Info Complete	06/04/2018 12:00:00 AM	ADDRESS	34.10411	-118.29162	PLAN CHECK FOR POWER AND ENERGY(T24 FEES COVERED UNDER MASTER APP) - CHANGE OF USE FROM (E) 915 SF RETAIL TO BAR AND 3161 SF RETAIL TO RESTAURANT AND BAR WITH UNCOVERED OUTDOOR DINNIG. INSTALLING NEW PANEL, LIGHTS, RECEPTACLES AND EQUIPMENT. A2 OCCUPANCY WITH MAX OCCUPANCY AT 170. - TOTAL AFFECTED AREA = 1008 SQ. FT. & 3077 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7612	19041-10000-25103	15208 W OXNARD ST	91411	4	177B145   474	2243019010	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.17913	-118.46423	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7613	15041-30000-43236	800 W WILSHIRE BLVD 2ND FLR	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.0493	-118.25841	Title 24 plan check only.  Total area = 12,450 sq. ft.  Office T.I. to 2nd floor of existing commercial highrise.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7614	10041-10000-14871	3025 S FIGUEROA ST	90007	8	120A203    13	5123010004	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	05/26/2011 12:00:00 AM	ADDRESS	34.0245	-118.27873	NEW FIRE ALARM SYSTEM. PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7615	16041-20000-15065	11232 W BRIARCLIFF LANE	91604	2	156B169   205	2381020015	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.12622	-118.3803	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20.48 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7616	17041-10000-46351	850 S GRAMERCY PL	90005	4	132B193   776	5092025030	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	05/05/2020 12:00:00 AM	ADDRESS	34.05648	-118.31308	PC for FA system for 4 story 18 unit apartment building. Installing 120 devices with one fire alarm panel, three rps panels and one annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7617	16041-10000-45054	4143 S CRENSHAW BLVD	90008	8	114B185   491	5032002040	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Info Complete	03/09/2017 12:00:00 AM	ADDRESS	34.00883	-118.33543	Full plan check for shell building remodel and addition to (e) building. Adding a new service rated at 1200A 120/208V 3phase 4wire. All new equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7618	11041-20000-12882	777 S FIGUEROA ST #3000	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Approved	06/21/2011 12:00:00 AM	ADDRESS	34.04828	-118.26116	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING TENANT IMPROVEMENT SUITE 3000. EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7619	15041-30000-44025	5825 W CAMERFORD AVE 1-34	90038	13	141B189   173	5534034016	R3-1XL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			12/31/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.0845	-118.3253	Installation of fire alarm system in new 3 story 34 unit apartment building.  Total system size = 89 devices + 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7620	16041-10000-20082	3000 S ROBERTSON BLVD 200	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING KAISER NATIONAL FACILITIES SERVICES (NFS) DEPT; NEW OFFICE AND MEETING SPACES WITH NEW RECEPTION. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4018 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7621	15041-30001-27422	5510 S LINCOLN BLVD Lobby	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	33.97299	-118.43051	Supplemental plan check for Title 24 only.  Addition of corridor space to scope of work.    Plan check Title 24 only for main entery lobby area in existing space. Total indoor area: 2,750 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7622	17041-30002-04779	6821 S VICTORIA AVE	90043	8	102B185   577	4006023004	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	33.97624	-118.33248	06/22/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 12,485 sq. ft.*****Previous Work Description*****Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 800 amps and new distribution equipment only. No load is included as part of this scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7623	19041-20000-21538	3560 S WATT WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.02169	-118.28671	Plan check for Title 24 only, in the existing space Physical Education Building (PED), existing fluorescent lighting to be replace  with new LED and to be controlled form main entrance door. Total area: 1,010 sq ft. B#19016-10000-12625	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7624	17041-10000-13615	650 S CATALINA ST	90010	10	132B197    69	5094007021	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.06159	-118.29525	PC FOR TI IN MIXED USED BUILDING.   NEW LOADS GREATER THAN 400ASCOPE INCLUDES NEW LIGHTS PANELS RECEPTACLES AND EQUIPMENT IN TWO COMM. UNITS AND FOUR RES. UNITSTOTAL AFFECTED AREA OF 2265 SQ.FTBuild. app # 16016-10000-06725	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7625	18041-10002-20923	20739 W DEARBORN ST	91311	12	198B109   144	2748036022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.23733	-118.58579	Resubmittal of rooftop (PV2) solar system due to lost original plan and design change.SOW: System size is 60 kW AC, install:             (5) inverters Fronius Symo 12 kW 3ph, 240V            (200) Modules CS3U-370MS            (1) 200A PV dedicated subpanel((Original plan was approved under 18041-10000-20923))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7626	14041-20000-03889	11661 W SAN VICENTE BLVD	90049	11	132B145   485	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.05407	-118.46431	PC FOR T24 ENERGY ONLY. TOTAL AREA 2524 SQ FT. NEW LIGHTING FOR GYM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7627	14041-20000-08563	13571 W GAIN ST	91331	7	204B157   978	2646018020	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.25361	-118.42863	solar system single family 4.0 kw	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7628	18041-20000-45125	2752 W DELOR ROAD	90065	14	159A219   143	5684018020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.13079	-118.2273	Install 13.5 kWh energy storage system and 125A critical load subpanel alongside (E) PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7629	15041-20001-18437			7	225B149   436	2505029005	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	PIN	34.31011422	-118.45737579	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7630	14041-20000-33474	14635 W HART ST	91405	6	183B149   343	2219012018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.19766	-118.45202	pv1 roofmounted central string inverter standard plan system size 8.0kw. 33 kyocera modules1 pvi 3.0 inverter1 pvi 5k inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7631	15041-10000-35550	18135 W SHERMAN WAY	91335	3	186B125   875	2119028001	[Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Issued	01/25/2016 12:00:00 AM	ADDRESS	34.20134	-118.52851	Power plan check for a service replacement of a 1600-Amp service with a 3-phase 3-wire @ 240V. new switchboard also being relocated to a new location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7632	17041-10002-18222	11000 N WESCOTT AVE	91040	7	210B189   194	2551044014	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Approved	06/21/2017 12:00:00 AM	ADDRESS	34.26894	-118.3173	plan check only for rearrangement for PV modules, and removal of junction boxes.Inspector to verify proper termination at each array to transition to conduit. Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 6 kWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7633	19041-20000-37635	1201 W EAGLE VISTA DR	90041	14	163-5A229 159	5691022016	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Expired	11/08/2023 12:00:00 AM	ADDRESS	34.14226	-118.18994	PV1. INSTALL 11.34 KW DC SOLAR SYSTEM WITH (36) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE10000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7634	17041-10001-24267	2351 S CLOVERDALE AVE	90016	10	123B177   403	5063008055	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.03544	-118.35632	CHANGES TO APPROVED SET OF PLANS. CHANGES TO POINT OF INTERCONNECTION. PV CONNECT TO UNIT SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7635	12041-20000-29398	1006 N SEWARD ST	90038	4	144B185   938	5533012025	[Q]MR1-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.08914	-118.33305	New restaurant in remodeled building.  Located in Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7636	17041-20000-42362	9841 N AIRPORT BLVD 2ND FLR	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Issued	11/22/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	PLANCHECK FOR T24 ENERGY.  TI TO COMMON COORIDOR AND RESTROOM UPGRADES. 2048 SQFT.BUILDING PERMIT # 17016-10000-18694	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7637	15041-20001-13493	1940 S LONG BEACH AVE EAST	90058	9	118-5A213 352	5167013039	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.01935	-118.24271	Expedite per applicant request{{{{{{Plan check for solar mounted roof top for commercial with 82.6 kW with 295 modules and 3 inverters(27.6kW) connected to load center(200A panel)}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7638	16041-10000-10814	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.07457	-118.37864	TENANT IMPROVEMENT OF EXISTING MEDICAL OFFICESPACE; NEW MR  EQUIPMENT AND CLEAN ROOM. PC FOR ENERGY ONLY (PER F.Y) TOTAL AREA: 593 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7639	17041-20001-02168	6339 N SUNNYSLOPE AVE	91401	2	180B157  1037	2330009028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.18601	-118.42701	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.11.52kW ungrounded system. (48) EnPhase M250 microinverters. (48) 275W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7640	16041-10000-26895	4634 W HOLLYWOOD BLVD	90027	13	147B197   478	5542014008	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.09998	-118.29031	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM OFFICE TO ICE CREAM SHOP.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 949 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7641	18041-10000-22451	3500 W WILSHIRE BLVD #206	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.04	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.06157	-118.30077	PLAN CHECK FOR TITLE 24 ONLY FOR TI (NO CHANGE OF USE - RESTAURANT TO RESTAURANT). TOTAL AFFECTED AREA = 520 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7642	14041-20000-19806	5058 N FLORISTAN AVE	90041	14	162A227   183	5689022023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.13858	-118.19863	3.5KW PV1 roof-mounted system with (14) Renesola Solar JC250 modules, (14) Solaredge power optimizers P300, and (1) Solaredge SE3800A-US transformerless inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7643	11041-10000-02361	2108 S MAPLE AVE	90011	9	121-5A207 111	5127016003	[Q]C2-2VL	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.0273	-118.26287	New service & panels for 26 units appartment units. EPC is for power. (Plan check was requested by inspector)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7644	13041-10000-19077	2801 E WABASH AVE	90033	14	130-5A227 307	5177012908	PF-1XL	East Los Angeles	Boyle Heights	Boyle Heights		2032.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Expired	08/18/2015 12:00:00 AM	ADDRESS	34.05059	-118.19785	NEW/RETROFIT FIRE ALARM SYSTEM ; 40 DEVICES  & 1 FIRE ALARM CONTROL PANEL.  DEVICES 42.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7645	18041-20000-19178	4108 N KRAFT AVE	91604	2	162B169   204	2368020023	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.14276	-118.37992	PV1.  Install 17.55 kW roof mounted grid tied PV system.  (54) modules with 7.6 and 6.0 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7646	16041-10000-19854	3508 W JEFFERSON BLVD	90018	10	120B185   871	5044004011	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.02545	-118.33421	TI to an (E) commercial build., change of use from hair salon to office space. PC for T-24 obly, total area: 960sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7647	13041-20000-26240	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.10686	-118.33085	PC FOR T24 ENERGY ONLY. FOR UNITS 102 AND 103.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7648	13041-20000-31837	1347 N AVENIDA DE CORTEZ	90272	11	138B117   334	4431005033	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.07175	-118.56039	PV1 TRANSFORMERLESS INVERTER. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7649	14041-10001-06744	3212 N BENDA ST	90068	4	157-5A183  37	5579036019	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			Reviewed by Supervisor	03/26/2014 12:00:00 AM	ADDRESS	34.1276	-118.34408	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(14) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7650	13041-20000-22904	20305 AVENIDA ALEGRE	0	12	210B113   223	2701075008	C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	PIN	34.27607388	-118.5754271	T24 FOR NEW Construction REC CENTER. TOTAL SQRFT 2200. TOTAL INDOOR 750 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7651	18041-20000-25128	7923 N MCNULTY AVE	91306	3	189B109   591	2108014007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.21419	-118.58469	Plan check for a PV1 roof-mounted PV system. System size is 14 kWdc/12.72 kWac-CEC and consists of (40) micro-inverters, (40) PV modules, (1) combiner box, (1) load center, and (2) Tesla PowerWalls.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7652	13041-10000-09635	4975 W PICO BLVD	90019	10	129B181   960	5070002037	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.04794	-118.34556	PLAN CHECK POWER AND ENERGY FOR EXISTING 3 STORY BUILDING. RENOVATION OF OFFICES TO STUDIOS. LOCATION IN METHANE ZONE HAZARD SITE. NO UNDERGROUND WORK DONE. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7653	16041-10000-10403	350 S GRAND AVE D5	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	TAKE OUT RESTAURANT. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7654	12041-20000-11927	2970 W OLYMPIC BLVD #303	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			Plans on Hold	05/25/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	nedical office # 303	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7655	11041-10000-27330	105 W CENTURY BLVD BLDG 1	90003	8	091-5A203  82	6053020029	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	33.94571	-118.27437	1-STORY RETAIL BUILDING #1 (3 TENANT SPACES). CORE AND SHELL.  TI UNDER SEPARATE PERMIT.  (BLDG # 2 IS UNDER PCIS # 11041-10000-27334)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7656	15041-20001-16290	936 S OLIVE ST UNIT 253	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #8 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7657	11041-10000-06790	6554 W HOLLYWOOD BLVD	90028	13	148-5A187 188	5547015017	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM	05/19/2011 12:00:00 AM		Permit Finaled	10/05/2011 12:00:00 AM	ADDRESS	34.10141	-118.3329	Change of use from retail to restaurant ~ 2576 S.F. remove uppermitted mezzanine( INTERIOR ONLY ) **	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7658	17041-10000-45097	713 W ANAHEIM ST	90744	15	030B205   386	7416021034	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	33.77971	-118.27046	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7659	19041-10000-37119	739 N NEW HIGH ST Ste 108,-109	90012	1	133-5A215  61	5408024011	C2-2	Central	Central City North	Historic Cultural North		2071.02	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.0612	-118.23821	PC FOR ENERGY ONLY, SCOPE OF WORK IS A CHANGE OF USE FROM RETAIL SPACE TO HAIR SALON. SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 1132 SQFT. B#19016-10000-14784	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7660	14041-10000-35252	12751 W MILLENNIUM SUITE B145	90094		102B161  1175	4211033020							Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM			Reviewed by Supervisor	01/26/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	PC FOR POWER AND ENERGY. FIRST TIME TENANT HAIR SASLON.TOTAL AREA1925 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7661	15041-20000-27673	5333 N OAK PARK AVE	91316	5	171B133    91	2258029014	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.16828	-118.50449	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (1) inverter and (38) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7662	15041-10000-15350	700 W CHILDS WAY	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.01978	-118.28463	10 ea wall-mounted luminaires for pedestrian walkwayplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7663	11041-20000-11294	14006 W RIVERSIDE DR #66	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Approved	07/14/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR RETAIL TI SPACE #66 (DISNEY STORE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7664	10041-10000-20385	1126 S WESTMORELAND AVE	90006	1	129B197   627	5076011004	R4-1XL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			10/13/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.04997	-118.28891	New fire alarm system for 4 story senor care housing.  fire alarm system is typical on all residential floors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7665	15041-20000-39897	1840 S CENTURY PARK EAST 7TH FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON THE 7TH FLOOR(OFFICE/CONFERENCE SPACE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL  AREA IS 4322 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7666	15041-20000-00668	11575 N GARRICK AVE	91342	7	213B173   188	2530031025	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.28026	-118.37901	PV1 SFD. TOTAL SYSTEM SIZE 3KW. THIS IS AN ADDITION TO EXISTING INSTALLATION. TOTAL PV TO BE 5.25KW IN ALL. THIS IS ONLY 3KW ADDITION. TOTAL OF 11 MODULES. NEW SUB-PANEL TO HANDLE ADDITION.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7667	15041-10000-40231	11311 W PENDLETON ST #B	91352	6	198B173     2	2538010006	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	09/09/2016 12:00:00 AM		Issued	09/09/2016 12:00:00 AM	ADDRESS	34.23563	-118.37732	PC FOR SERVICE UPGRADE TO SITE. NEW 800A SERVICE. REFEED EXISTING TRAILER AND NEW 400A DISCO FOR CONCRETE PLANT. LOCATION IN METHANE ZONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7668	12041-10000-24065	2914 W 8TH ST	90005	1	132B197   497	5077023015	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Closed	11/13/2012 12:00:00 AM	ADDRESS	34.05751	-118.28966	TEMP. 800 AMP  SERVICE FOR CONSTRUCTION OF AN APARTMENT BILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7669	16041-20001-07601	625 N NORTH BROADWAY	90012	1	133-5A215 171	5408016001	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	PIN	34.05963177	-118.24010092	04/06/2017 CHANGES TO APPROVED SET. DELTA 4 CHANGES ARE CLOUDED. CHANGES TO LOAD AND T-24 LIGHTING*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT.  RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7670	10041-10000-09198	448 S HILL ST # 1001	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	05/17/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.04896	-118.25139	INTERIOR IMPROVEMENT IN OFFICE AREAS; PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7671	19041-20000-02917	7428 N VARNA AVE	91605	2	186B157   316	2328029010	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.20563	-118.42457	600A 240/120V 3ph-4w service upgrade for new warehouse and (E) commercial buildings on lot.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7672	14041-20000-01407	6143 W MARYLAND DR	90048	5	135B177   256	5510011007	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.06684	-118.36294	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KWA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7673	15041-20002-12657	7600 N LINDLEY AVE	91335	12	186B125   197	2120018009	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.20876	-118.52715	5.3.2017 - Plan check for modifications to approved set. Update AIC ratings of main service panel and unit panels. Changes clouded.=======PLANCHECK FOR POWER AND ENERGY. NEW 1-STORY RETAIL MINI-SHOPPING CENTER:  5-Retail tenant spaces. conduit variance has been filed for underground conduits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7674	15041-10000-11530	14400 W FRIAR ST	91401	6	178-5A151  53	2240002014	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.18554	-118.44668	NEW FIRE ALARM SYSTEM. 29 UNITS 4 STORY BUILDING. 134 DEVICES AND ONE FA PANEL AND ONE ANNONCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7675	19041-30000-52651	2029 S CENTURY PARK EAST Suite ROL-15	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	05/17/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SOCPE INCLUDES NEW LIGHITNG, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 1328 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7676	19041-10000-07162	14401 W FRIAR ST	91401	6	180B149  1012	2240001900	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.18583	-118.44668	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR AND OUTDOOR) - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7677	19041-10000-11729	4451 N BEN AVE	91607	2	165B165   112	2364013028	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM			Reviewed by Supervisor	04/25/2019 12:00:00 AM	ADDRESS	34.15198	-118.39444	[e-plan]PV1 FULL PLAN CHECK. Revison to already permitted solar PV (18041-90000-44607) -- added an inverter and swapped out an inverter to make them both compatible with the backup battery system, added (1) ESS LG Chem RESU10H 9.8 kWh.PV System size now become 10.6 kW AC. Quantity of modules and optimizers remain the same as previously approved PV.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7678	14041-20000-02667	655 W WEST 34TH ST	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.02201	-118.28217	T24 FOR CONTROLS ONLY FOR PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7679	15041-20001-27131	1314 E ADAMS BLVD	90011	9	117A211    64	5118011017	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.0162	-118.2497	Expedite fees only.    Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7680	15041-20000-39888	14991 W VALLEY VISTA BLVD	91403	4	165A147   164	2276025014	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.14672	-118.46096	PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service panel.(35) Sunpower SPR 327W Modules(35) Solar Edge P400 Power Optimizers(1) Solar Edge SE 10,000A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7681	16041-10000-41746	610 W CYPRESS AVE	90065	1	144A219   287	5453014030	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.08845	-118.22244	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 29725 SQ FT. (OUTDOOR LIGHTING)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7682	19041-10000-11839	1040 N LAS PALMAS AVE STAGE 5	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7683	12041-20000-03090	3800 N VALLEY MEADOW ROAD	91436	5	162B141   246	2286019016	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2012 12:00:00 AM			PC Approved	05/25/2012 12:00:00 AM	ADDRESS	34.13982	-118.47905	New ground mounted PV system with 26.16KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7684	11041-20000-26707	10802 S AVIATION BLVD On Site	90045	11	087B173    10	4129036***	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	PIN	33.93781677	-118.37450857	Install new 600 ampere service to replace deteriorated existing 600 ampere service in same location, no loads added.  Inspector to verify proper grounding electrode conductor, and AIC rating of the new 600 ampere standing service disconnect.  DWP indicates available short circuit current of 47000 amperes at the service meter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7685	15041-20001-08230	17965 W MAYERLING ST	91344		216B129   169	2601029015							Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.28804	-118.52425	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 11 kWac.  Single inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7686	11041-10000-12745	800 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/26/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of  1 elevator unit in terminal 8 at LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7687	19041-10000-23313	5600 W ADAMS BLVD	90016	10	123B177  1053	5048029023	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/18/2021 12:00:00 AM	ADDRESS	34.03231	-118.36491	Full plan check for a 3-story mix-use office and retail building over a subtaranian parking.Scope includes (1) new 1200-Amp service, (12) panels, and other new equipment with a total lighting area of 62,873-SQ FT.Building Permit: 18010-10000-00076	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7688	16041-10000-32616	2632 W 15TH ST	90006	1	126B197    68	5075014007	RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.04524	-118.29918	PC FOR TITLE 24 ONLY.SCOPE INCLUDES NEW LIGHTING FOR OUTDOOR PARKING. SPACE TOTAL AREA  20380 SQ0FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7689	15041-10000-00685	1581 E 21ST ST	90011	9	118-5A213 156	5118002026	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.01844	-118.24496	Plan check for PV1 roof top mounted. System size: 5kW with 16 modules and 1inverter. Pulling permit in person because of B contractor license. Cannot pull online.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7690	16041-10001-32621	3761 S HILL ST	90007	9	117A203    89	5122028006	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.01524	-118.27792	PLAN CHECK FOR LOST SET OF CORRECTIONS LIST REDLINE SET AND SPECS TO ALL DEVICES HAVE BEEN INCLUDED FOR VERIFICATIONPlan check for New fire alarm system in commercial building. Total fire alrm devices: 208 and 1 FACP and 6 power supply	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7691	19041-10000-53504	11204 W HORTENSE ST	91602	4	168B173   900	2353034010	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.1544	-118.37471	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 22 (REC290TP2) MODULES, 22  POWER OPTIMIZERS, 1 CENTRAL (SE5000-H-US) INVERTER, CONNECTED TO AN EXISITING 200A MAIN SERVICE PANEL.  SYSTEM SIZE:6.38KW DC, 5.00KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7692	15041-20001-12429	20500 W NATOMA ESTATE DR	91364	3	165A111    11	2174010031	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM			PC Approved	05/11/2015 12:00:00 AM	ADDRESS	34.14813	-118.58067	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 13.8 kWac and consists of (3) inverters, (73) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7693	18041-10000-21710	2444 S ALAMEDA ST	90058	14	117A215    57	5167006034	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.01494	-118.23943	PLAN CHECK FOR TITLE 24 ONLY TO REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7694	15041-10000-10097	6925 S KNOWLTON PL	90045	11	102B173   321	4103012045	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Public Safety Only			04/06/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Issued	04/06/2015 12:00:00 AM	ADDRESS	33.97414	-118.37142	NEW FIRE WARNING SYSTEM FOR 3-STORIES APT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7695	17041-10000-30601	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	Plan check power and energy for 1st time tenant for 4 tenant spaces(#192,198,188,196). Total area: 6262 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7696	19041-10000-23234	4642 W RUSSELL AVE	90027	4	150B197  1044	5590020900	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.10439	-118.29103	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7697	11041-10000-19586	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	11/15/2011 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	33.95466	-118.38556	Photovoltaic modules mounted on roof and carports.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7698	17041-10000-08449	711 E 119TH ST	90059	15	084B205   952	6084008025	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	33.92478	-118.26145	Installation of a PV1 roof mounted solar system. Central inverter 3.0KW, 14 Solar modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7699	15041-20001-18780	9700 N LAUREL CANYON BLVD	91331	7	201B161   612	2626005032	[Q]C1.5-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.24593	-118.41825	Expedite per applicant request[[[[[Plan check for PV roof mounted system. System size: 7.6kW with 32 modules and 1 inverter(7.6kW) in a multi family]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7700	12041-10000-19101	11205 S BROADWAY	90061	8	087A203   167	6074024002	R3-1	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Apartment			08/14/2012 12:00:00 AM			Verifications in Progress	11/02/2012 12:00:00 AM	ADDRESS	33.93272	-118.27879	New rooftop photovoltaic system for an existing apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7701	17041-20000-33232	12940 W ADDISON ST	91423	4	168B161    16	2358023021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.16107	-118.41537	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (27) modules. PV system interconnects with a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7702	12041-20000-14270	900 S FIGUEROA ST	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.04604	-118.26272	T.I. to high rise building 1st floor.  Install general/emergency lighting in office, lounge, and restrooms area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7703	19041-10000-47972	1400 S GRAND AVE 700	90015	14	124-5A207  58	5134020023	C2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	09/29/2020 12:00:00 AM	ADDRESS	34.03697	-118.26528	FULL PLAN CHECK FOR ATENANT IMPROVEMENT OF A SURGERY CENTER OUTPATIENT MEDICAL CLINIC. SCOPE INCLUDES NEW EQUIPMENT, PANELS AND TRANSFORMERS FED FROM AN EXISTING 2000A SERVICE AND EXISTING EMERGENCY GENERATOR .PER BUILDING PERMIT # 19016-10000-37538TENANT IMPROVEMENT OF APPROX. 6,200 SF OF OUTPATIENT CLINIC ON THE 7TH FLOOR OF TYPE 1A BLDG.  FOR OSHPD3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7704	17041-10000-43203	1047 E VERNON AVE	90011	9	112-5A209  11	5115014029	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.00409	-118.25729	REMOVE OUTDOOR HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7705	15041-10000-35779	900 N ALAMEDA ST CR4	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR POWER AND ENERGY. INSTALL UPS, POWER DISTRIBUTION AND LIGHTING FOR NEW COMPUTER ROOM. 4 * 500 KVA UPS MODULES PLUS 4 POWER DISTRIBUTION UNIT 1000KVA EACH. TOTAL AREA 12500 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7706	13041-20000-32982	15211 W COBALT ST	91342	7	225B145   236	2501010007	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM			PC Approved	11/25/2013 12:00:00 AM	ADDRESS	34.31284	-118.46364	"Plan Check Only for Modification to approved set of plans to change number of conductors for feeder ""C"" from 3 to 4 only.  Original Plan Check/Permit is on #13041-20000-24872        <<<PV1 TRANSFORMERLESS SYSTEM. 16 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 4.1 K>>>W"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7707	12041-20000-16770	11676 W SHELDON ST	91352	6	201B169   137	2538004021	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.24426	-118.38667	New industrial building with new 2000A service.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7708	11041-10000-10995	1440 W JAMES M WOOD BLVD	90015	1	130-5A205 364	5137005021	C2-1	Central	Westlake			2100.10	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM	05/27/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	PIN	34.04972848	-118.27117837	T.I. title 24 and emergency lighting.  4 story building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7709	17041-20000-17592	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Issued	01/04/2018 12:00:00 AM	ADDRESS	34.04538	-118.26335	Plan check for energy only. New common area lighting (stairs, corridors, etc.) on all levels of existing 5-story (over basement) commercial building. 19,246sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7710	15041-10000-13058	5053 N FAIR AVE	91601	2	171B173  1010	2353012037	R4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.16224	-118.37474	NEW FIRE ALARM SYSTEM FOR NEW 4-STORY , 36 UNITS APARTMENT BUILDING. 113 FA DEVICES, 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7711	18041-10000-23205	1660 W ANAHEIM ST	90731	15	030B197    11	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	33.77884	-118.29327	PC FOR POWER ONLY FOR A OIL REFINARY. SCOPE INCLUDES ADDING A NEW FEEDER IN A HAZARDOUS LOCATION IN A CLASS 1 DIV 2. ALSO ADDING TWO NEW 100AM PANELBOARDS, AND NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7712	12041-20000-25140	6210 N CARPENTER AVE	91606	2	177B169   344	2334008049	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Permit Finaled	02/12/2013 12:00:00 AM	ADDRESS	34.18337	-118.39092	Enphase system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7713	14041-10000-06073	14232 W AETNA ST	91401	6	177B153   826	2240025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.18007	-118.4433	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 3191 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7714	17041-10000-11567	1245 W WILSHIRE BLVD #770	90017	1	132A207   288	5143017041	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	TI FOR MEDICAL OFFICE. PC FOR POWER AND ENERGY. SUITE 770. NO CRITICAL CARE AREAS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7715	17041-10002-37515	1400 N CAHUENGA BLVD	90028	13	147A187   280	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	34.09641	-118.32933	Changes to approved plan, noted as Delta2, Delta-3, and Delta-4, 5 & 6. (3) pages of Narrative of changes are included. SOW includes: Replace, relocate, and add circuitry/loads;  add 2 panels; plan includes PV design; however, fee for PV is not included with this submittal.<<<FULL PC FOR POWER AND ENERGY. NEW 8 STORY HOTEL WITH RESTAURANT AT GROUND FLOOR (CORE&SHELL ONLY) AND TOP LEVEL AMENITY WITH THREE SUBTERRANEAN GARAGE BASEMENTS.  SCOPE INCLUDES A NEW 2500A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 27,500 SQ. FT. B#16010-10000-05898>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7716	09041-20000-16487	13260 W SHERMAN WAY	91605	2	183B157    93	2327004037	C2-1VL	South Valley	North Hollywood - Valley Village			1234.10	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.20103	-118.42199	Remodel exist food mart bldg., located @ an exist. motor fuel dispensing facility. (Phase 2 of 2)  The 600A service is part of Phase 1of 2 with separate application PCIS 09041-20000-12061.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7717	18041-10000-47830	14629 W NORDHOFF ST	91402	6	198B149   557	2651009021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Issued	12/18/2018 12:00:00 AM	ADDRESS	34.23558	-118.45117	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7718	16041-20000-38003	3704 N CAHUENGA BLVD	91604	4	159B177    62	2425001053	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.13554	-118.36147	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is an addition. Total lighting area = 1,197 sq. ft.Note: Building application has been generated under 16014-20000-05083	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7719	19041-20002-30069	2459 N HAVERHILL DR	90065	1	153A219   124	5462024037	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.11441	-118.22383	08-28-2019 Changes to an approved set of plan, Changes include module layout, same number of modules.Changes has been clouded. Fess $ 0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7720	12041-10000-24729	10720 W CHALON ROAD	90077	5	141B149   146	4362003035	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM			PC Info Complete	09/09/2013 12:00:00 AM	ADDRESS	34.08291	-118.44997	NEW TWO STORY ( 7836 S.F.) SINGLE FAMILY DWELLING WITH ATT. 3 CAR GARAGEThis building has a 600 ampere service.second application will be for the accessory living quarters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7721	14041-10000-13378	3434 S GRAND AVE	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Expired	09/12/2016 12:00:00 AM	ADDRESS	34.01912	-118.27658	Retrofit existing flourescent light fixtures with LED retrofit kits on the 1st through 5th floor offices.  1st-2nd floor area = 13,662 sq ft3rd-5th floor area = 22,743 sq ftTotal area = 36,405 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7722	18041-20000-22242	7530 N VAN NUYS BLVD	91405	2	186B149   193	2215001008	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	04/22/2020 12:00:00 AM		Issued	04/22/2020 12:00:00 AM	ADDRESS	34.20782	-118.44856	New 600A 480Y/277V 3ph-4w service for (E) carwash.  Replacement of 400A MCC and associated motor loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7723	10041-10000-10673	2065 W 6TH ST suite 115	90057	1	133-5A203 165	5154029027	C2-2	Central	Westlake		YES	2089.03	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM			PC Info Complete	06/07/2010 12:00:00 AM	ADDRESS	34.05948	-118.27435	Ti in a take out restaurant. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7724	13041-20000-19567	21724 W VENTURA BLVD	91364	3	171B105    42	2168024064	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.16814	-118.60156	energy plan check state bank of india	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7725	15041-20000-28379	16801 W PACIFIC COAST HWY	90272	11	126B121   537	4415034003	A1-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.03976	-118.54574	Power plan check only.  Installation of new 150 kW emergency backup generator and 1,200 A TS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7726	15041-10000-23160	777 S FIGUEROA ST #600	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.04828	-118.26116	PC FOR POWER AND ENRGY. CHANGE OF USE. MALASIAN GENERAL COSOLATE. TOTAL AREA 14820 SQ FT. PER APPLICANT REQUEST ADN FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7727	19041-10000-21339	1075 N WESTERN AVE 101	90029	13	144B193   779	5536019024	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.0902	-118.30943	T-24 PLAN CHECK FOR AN INTERIOR TI OF T-MOBILE RETAIL STORE. SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1795 SQ.FT.TOTAL CONNECTED LOAD IS LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7728	14041-20001-32434	550 S HILL ST SUITE 1635	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Approved	02/09/2015 12:00:00 AM	ADDRESS	34.04753	-118.25268	changes to an approved set of plans.  changes noted by delta1 on plans.  changes include lighting fixtures and em lighting.TI TO AN EXISTING COMMERCIAL TENANT SPACE IN A HIGH RISE BUILDING.  INSTALLING NEW LIGHTING FIXTURES INTO EXISTING PANELS.  WORK TO BE PERFOMED IN SUITE 1635.  TOTAL AREA 1,910 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7729	14041-10000-22517	20810 W LASSEN ST	91311	12	201B109   117	2748004058	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.24984	-118.58674	T24, REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 7416 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7730	14041-20000-22352	18246 W VANOWEN ST	91335	3	180B125    29	2125020014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.19372	-118.53118	New roof mounted PV system Optimizers.  Total system size 3.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7731	13041-20006-35652	1455 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Approved	12/11/2015 12:00:00 AM	ADDRESS	34.09728	-118.31598	12/11/15Changes to an approve set. Changes made under delta 5. Scope includes removing lights and relocating loads. (((NEW 7  ELEVATED LEVELS AND 2 BELOW GRADE PARKING STRUCTURE PLAN CHECK. PLAN CHECK FOR POWER AND ENERGY. NEW 2000A UNDERGROUND, 480/277V,3PH,4W. PROJECTED LIGHTING AREA IN SCOPE OF WORK IS APPROX. 581,525 SQ FT(INDOOR CONDITION/UNCONDITIONED + OUTDOOR ). 600A EMERGENCY DISTRIBUTION BOARD VIA 400A ATS, FED FROM 350kW/486 KVA EMERGENCY STANDBY DIESEL GENERATOR.building permit: 13010-10000-04219	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7732	13041-10000-33005	12100 N SALEM DR	91344	12	216B133   184	2606011028	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.29019	-118.50819	PV1, Install 8 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(2)Transformerless inverter(s): SolarEdge SE3800A-US. (32) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7733	10041-20000-07376	18505 W DEVONSHIRE ST	91326	12	204B125   652	2728028025	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	PIN	34.25861591	-118.5365027	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT OF EXISTING RESTAURANT (TYPE A OCCUPANCY)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7734	19041-20000-47903	10831 W ESTHER AVE	90064	5	126B157  1216	4255025016	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.03814	-118.42617	PV1.  Install 6.8 kW roof mounted grid tied PV system.  (17) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7735	18041-10001-10419	10250 W SANTA MONICA BLVD #1700	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Info Complete	10/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	CHANGES TO APPROVED SET OF PLANS.  ALL CHANGES ARE CLOUDED UNDER DELTA 15 & 18. CHANGES INCLUDE RELOCATION AND ADDITION OF NEW EQUPMENT, LIGHTING LAYOUT INCLUDING PHOTOMETRICS CHANGES (B# 18016-10000-08601)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7736	17041-10000-24100	10250 W SANTA MONICA BLVD LL1850	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Remodel commercial tenant space- Autospa Ste.# LL1850. Panel for this tenant is pulled from Westfield's house panel ELA33LD1.full plan chk	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7737	18041-10001-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.26056	-118.35206	EXPEDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 11.0KWAC/ 16.8KWDC (OPTIMIZERS)SCOPE INCLUDES 42 MODULES WITH OPTIMIZERS AND 2 CENTRAL INVERTERS. EXSITING SERVICE AT 600A  120/240 NEW ESS UNDER  10003 SUPP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7738	17041-20001-45813	1001 N SEWARD ST	90038	4	144B185   940	5532024007	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	34.08914	-118.33334	"08-09-2019 Changes to an approved set of plan, changes include lighting manufacture and layout, revise Single Line Diagram, power and equipment. All Change has been clouded as delta ""H"". Narrative of all changes has been provided. {{{{{{Plan check for power and energy. New 4-story+mezzanine commercial building over one level of basement parking. Core and shell. 4,000A 277/480V 3ph 4w service. T24 area: 137,229sqft. Project is located in methane zone. Building permit application #17010-10000-04278.}}}}}}"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7739	15041-10000-09385	5620 N WILBUR AVE	91356	3	174B121   416	2160002042	(Q)CR-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.17273	-118.54456	Full plan check for medical office. All lighting is new. total area is 1264-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7740	15041-10001-25064	11734 W AVON WAY apt# 101	90066	11	111B161  1318	4233022***	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM			Reviewed by Supervisor	08/12/2015 12:00:00 AM	ADDRESS	33.99813	-118.41672	EXPEDITED RSES PLAN CHECK PERT APPLICANT REQUEST.<<<pv1, install 2.65 roof-mounted solar array on a single family house.(10) modules:kyocera ku2656zpa (1) inverter: abb pvi-3.0-outd-s-us-z-a>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7741	16041-10001-19086	1254 S WESTWOOD BLVD	90024	5	132B153   497	4325005022	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM			PC Approved	09/23/2016 12:00:00 AM	ADDRESS	34.05776	-118.44302	09/23/16Changes to an approved set of plans. Changes include replacing fluorescent lighting fixture with LED lights. ((((((T-24, PC for energy only. Change of use from Retail to Massage Parlor. TI to an existing commercial building. Scope includes new lights and receptacles. Total affected area is 1045 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7742	18041-20000-21998	312 S HILL ST 2nd Floor	90013	14	130-5A211  79	5149015025	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	08/20/2020 12:00:00 AM	ADDRESS	34.05123	-118.24929	Plan check for Title 24 Energy only in existing space in the building office T.I. Total area: 8670 sq ft.B#18016-30000-15010	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7743	14041-10000-13096	1548 W FAIR PARK AVE	90041	14	160-5A227 276	5689026011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.13372	-118.19976	PV1, INSTALL  2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. SANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7744	11041-10000-22968	4277 S WESTERN AVE	90062	8	114B193  1268	5021027027	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Public Safety Only			10/26/2011 12:00:00 AM	10/26/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	34.00572	-118.30915	NEW FIRE WARNING SYSTEM FOR A SINGLE STORY BUILDING-CHILDRENS' INSTITUTE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7745	15041-20000-20660	16633 W VENTURA BLVD Suite 1008	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.15823	-118.49571	TI to existinc high rise commercial building. Plan check for energy only. Adding new lighting. Total sqft. 632	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7746	18041-10001-10667	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	01/18/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	PLAN CHECK ONLY FOR CHANGES TO AN APPROVED SET OF PLANS. CHANGES ARE NOTED UNDER DELAT 5 ONLY. SCOPE OF WORK INCLUDES CHANGE OF CONDUCTORS TO AIR HANDLING UNITS NOTED ON SINGLE LINE DIAGRAM. _________________________________________________________________PREVIOUS DESCRIPTION -FULL PC FOR A WAREHOUSE, STUDIO BUILDING TI. SCOPE OF WORK INCLUDES NEW 4000A, 277/480V SERVICE., NEW CIRCUITS AND LIGHTING. TOTAL SQ. FT. 163,096B# 18016-10000-08591	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7747	17041-10000-28379	4470 N EAGLE ROCK BLVD	90041	14	157-5A221 174	5474008012	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.12572	-118.21905	REMOVE HID  FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY.Total affected 17025 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7748	13041-10000-06077	9637 N SHOUP AVE	91311	12	201B101   886	2727002033	(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.24545	-118.61501	Roof mounted P.V. system with 14.7 KW for a SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7749	14041-10000-28388	12200 W OLYMPIC BLVD	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Info Complete	04/14/2015 12:00:00 AM	ADDRESS	34.03195	-118.45506	PC FOR POWER AND ENERGY. ADD GENERATOR IN LOWEST LEVEL(LEVEL 2) OF BASEMENT PARKING GARAGE. TOTAL AREA 300 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7750	17041-10000-23919	3201 S HOOVER ST Ste 1810	90007	9	121-5A201 201	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	06/21/2018 12:00:00 AM		Issued	06/21/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	PC for power and energy for new restuarant TI. Load over 400 A. Total sqft 4870  .Building PC 17016-10000-14043.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7751	10041-10000-04217	725 S FIGUEROA ST 5TH&6TH-FLOORS	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/10/2010 12:00:00 AM	ADDRESS	34.04886	-118.26071	TENANT IMPROVEMENT IN THE REST ROOMS ON THE 5TH & 6TH FLOORSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7752	14041-20000-33422	3201 S OVERLAND AVE 1-525	90034	5	120B161     7	4254011036	R1-1, R3-1, R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			12/03/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.02928	-118.41552	Permit fee is $0.00 due to 2012 State Senate Bill 1222.PV2.Install a roof-mounted solar array on a 525 unit apartment building. Interconnect with 1200A MSP.System size: 301kW (Seven 23kW inverters & Five 28kW inverters). Ungrounded system.999  310W pv modules. Equipment shown as 'Future' is to be installed under this permit, include in plan check.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7753	14041-20000-13461	5520 N COLUMBUS AVE	91411	4	174B145   604	2250006019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.17092	-118.46381	PV1.  Install 7.5 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7754	19041-20001-44640	5805 N SEPULVEDA BLVD	91411	4	174B145   102	2243001009	M1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			PC Approved	02/27/2020 12:00:00 AM	ADDRESS	34.17593	-118.46647	Expedite fee.PV3.  Install 166.5 kW DC carport mounted PV system.  (444) modules with (3) 33 kW rated inverters and (1) 62 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7755	19041-20000-51055	4311 N LOUISE AVE	91316	5	165B133   212	2292017013	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.14994	-118.50689	PV1.  PV roof mounted system, PV system size: 11.34KW with 36 PV Modules and 1 inverter(10.0KW), Energy Storage System size: 40.5KWh, 3 Energy Stroage System Tesla Power Wall connected to Existing 400A Service.$0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7756	16041-20000-13179	990 N WESTERN AVE	90029	13	144B193  1132	5535021019	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.08825	-118.30896	TI - replacement of all lighting to LED fixtures for (E) commercial restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7757	15041-10003-07468	759 N SPRING ST	90012	1	133-5A215  38	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	PIN	34.06161992	-118.23745547	Changes to approved set under delta 2.  Changes to control system for outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7758	16041-10000-33154	5333 W ZOO DR	90027	4	162B197     2	5593002905	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.14867	-118.28623	T-24, PC FOR ENERGY FOR AN EXISTING ZOO WALKWAY. SCOPE INCLUDES NEW LIGHTS FOR AN EXISTING WALKWAY. TOTAL AFFECTED AREA IS 60,000 SQ, FT,	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7759	15041-10000-31523	9237 N SAN FERNANDO ROAD	91352	6	198B169   139	2631003020	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.23695	-118.39155	T-24. PC FOR ENERGY ONLY. TI ON EXISTINC COMMERCIAL BUILDING (WAREHOUSE). SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA IS 13600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7760	13041-20000-26632	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	33.78734	-118.29768	FULL PLAN CHECK FOR EXISTING MEDICAL OFFICE. 1887 SQRFT. PER APPLICANT NOT OSHPOD3 BUILDING. THIS IS RESUBMITTAL FOR LOST PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7761	17041-20001-43924	6707 W 88TH ST	90045	11	096B161   808	4122020011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			Reviewed by Supervisor	12/12/2017 12:00:00 AM	ADDRESS	33.95725	-118.4071	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.5kW ungrounded pv system. (16) 325W pv modules. (1) Tesla Powerwall 2.Each pv module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7762	14041-20000-00681	13055 W ARROYO ST	91340	7	216B161    38	2514002042	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.29079	-118.41748	NEW WAREHOUSE WITH 1200A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7763	18041-10000-10629	638 S BEACON ST	90731	15	015B201   171	7455026900	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	33.73807	-118.28029	Title 24 plan check.  TI on 7th floor of existing historical highrise building.  Subpanels to remain existing with new lighting and receptacles.  Lighting area = 3,261 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7764	16041-10000-44810	1115 S CARDIFF AVE 1-21	90035	5	132B169   536	4332002026	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			12/21/2016 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.05666	-118.39202	FULL PC FOR POWER AND ENERGY FOR A NEW 5 STORY 21 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW 1600A 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 21245 SQ. FT. B#15010-30000-01232	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7765	14041-10000-11676	8215 N CANTALOUPE AVE	91402	6	192B153   957	2213010014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.22016	-118.43586	Install roof-mounted solar array, interconnect with main panelSystem size =  2.75 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7766	16041-20000-19366	3551 S TROUSDALE PKWY #260	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.02066	-118.28531	Plan check Title 24 only in existing space T.I. USC Bovard Administration Building (ADM). Total area: 372 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7767	17041-10000-11119	2821 N BALDWIN ST	90031	1	138A223   412	5204019022	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.0703	-118.212	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  11350 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7768	17041-10000-42167	9134 N VAN NUYS BLVD	91402	6	198B149   507	2639008134	P-1VL, [Q]C2-1VL, [T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.23637	-118.45006	REPLACEOUTDOOR LUMINAIRES WITH LED TYPEPLAB CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7769	15041-20000-14180	12429 W VENTURA BLVD	91604	2	162B165   208	2367018026	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM			PC Info Complete	06/11/2015 12:00:00 AM	ADDRESS	34.14295	-118.40409	Plan check for power and energy.  Total area = 2,279 sq. ft.  T.I. to existing commercial restaraunt space.  New 600 A service and electrical distribution system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7770	16041-20000-45470	3310 S WADSWORTH AVE	90011	9	117A209   408	5114018027	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.01337	-118.25882	ti to an existing commercial building.  adding new lighitng new controls to existign panels.  plan check for enegy only total square footage 6899	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7771	15041-10000-03371	380 WORLD WAY T-09	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Title 24 only. Project space is retail. Space is located in Tom Bradley International Terminal (Space T-09). Total lighting area = 160 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7772	16041-20001-04094	15937 W ARMINTA ST	91406	6	189B141   128	2206007024	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	PIN	34.21419799	-118.48096065	Revisions to approved set of plans.  Revisions under delta 2, 3, 4, and 5.   Minor changes to luminaire schedule, change of (N) service from 200A 240/120V 1ph-3w to 400A 240/120V 3ph-4w.  Additional subpanel for lighting loads.(((Plan check for Title 24 only for new Wearhouse/office. Total area: 1,600 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7773	14041-20001-04064	14958 W SEPTO ST PV1	91345	7	201B149   112	2647010042	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.2508	-118.45843	][[] EXPEDITED PER APPLICANT REQUEST ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 125 MAIN SERVICE PNL. TRANSFORMERLESS SYSTEM, SIZED @ 6 kW DC, WITH (24) TRINA SOLAR TSM-250W MODULES, (24) SOLAREDGE OPTIMIZERS OP300-MV, (1) SOLAREDGE INVERTERS, SE6000-US-ZB-U,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7774	14041-20000-12159	5591 E HUNTINGTON DR NORTH	90032	14	147A239   269	5309024018	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.09532	-118.15849	PLANCHECK FOR T24 ENERGY FOR AN OPTICAL RETAIL STORE. NOT A CLINICAL CARE ACCORDING TO APPLICANT. 1146 SQFT, EMERGENCY LIGTHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7775	17041-10000-03705	10880 W WILSHIRE BLVD SUITE 915	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.05885	-118.44283	T.I. to suite 915. office ti. pc for energy only t24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7776	16041-10002-16336	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	Changes to an approved set of plan. Changes include revised lighting on floor plan for different type of fixture manufacture, added (2) new switchgears ratted 2500A 480V. Changes has been clouded under delta 8.  LOW RISE Building using Centeral Inverter for emergency lights.<<<<<<<<FULL PC FOR POWER AND ENERGY. NEW 4000A 277/480 3 PHASE 4 WIRE SERVICE FOR A NEW 8-Story Media Production Office Building (core and shell). TOTAL AFFECTED AREA IS 154499 SQ. FT.         Fire alarm variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7777	15041-10000-03628	432 S CURSON AVE TOWER 50-50-04L	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.0673	-118.35362	INSTALL (1) 100 AMP PANEL & (8) NEW CIRCUITS	N	N	Express Permit	06/10/2024 12:00:00 AM
7778	18041-20000-30362	424 N CROFT AVE	90048	5	141B173  1358	5514002038	R1V3-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Expired	09/20/2023 12:00:00 AM	ADDRESS	34.07889	-118.37407	Plan check for battery back up system to existing PV System, 2 LG Battery connected to existing PV inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7779	16041-10000-40319	760 S WESTMORELAND AVE	90005	1	132B197   421	5077019017	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.05811	-118.28889	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures for outdoor use. Total affected area is 26350 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7780	19041-10000-01690	1707 W 265TH ST	90710	15	030B193    79	7411028025	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	33.78107	-118.30745	PV1. NEW SOLAR SYSTEM WITH STORAGE BATTERY ON EXISTING RESIDENTIAL HOME. TOTAL SYSTEM SIZE IS 8.96Kwdc / 7.6KWac. TOTAL STORAGE BATTERY 9.8KWH LG CHEM RESU10H  (28)MODULES-PANASONIC GROUP VBHN320KA01(28)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE7600A-USS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7781	14041-20000-25259	11133 W VANOWEN ST	91605	2	183B173   182	2319005017	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.19409	-118.37363	Plan check for energy only. TI to existing food processing building. New lighting, incl. emergency. 2288sqft. Applicant says TI is part of building permit #14016-20000-00575 which falls under 2008 Title-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7782	19041-20000-22159	1363 W COLTON ST	90026	1	135A209   208	5160011006	CW	Central	Westlake	Echo Park	YES	2080.00	Electrical	Electrical	Apartment			06/11/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.06386	-118.25842	Fire alarm system for new 8-story 47-unit apartment building.  (175) signaling and notification devices, (1) FACP, annunciator and (4) remote power supplies.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7783	13041-20000-08813	16624 W VENTURA BLVD	91436	5	168B137   819	2284007016	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.1578	-118.49544	Change of use from Retail to Hair Salon.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7784	10041-10000-25766	1160 W HARRY BRIDGES BLVD	90744	15	027B201   208	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM			Verifications in Progress	04/04/2012 12:00:00 AM	PIN	33.77018478	-118.27675111	NEW 1-STORY DRIVER SERVICE BUILDING FOR THE PORT OF LA. EPC IS FOR POWER & ENERGY. FIRE ALARM PLAN WAS SUBMITTED SEPARATELY. (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7785	16041-20000-08509	11955 N WIMBERLY AVE	91342	7	216B149   487	2611025006	RS-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.28756	-118.45642	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (28) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7786	13041-20000-08171	22708 W VICTORY BLVD	91367	3	180B097   634	2039020026	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.18625	-118.62139	Plan check for energy only. Bathrooms for AAA.ACCESSIBILITY IMPROVEMENTS:  UPGRADE HC PARKING (5 ACCESSIBLE SPACES) AND FIRST FLOOR RESTROOMS.  122 STANDARD SPACES AND 5 HC SPACES PROVIDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7787	15041-10000-00558	12499 W OSPREY LANE Bld-16	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Issued	01/08/2015 12:00:00 AM	ADDRESS	33.97883	-118.41112	Plan check for new fire alarm system with (1) fire alarm control panel and 40 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7788	18041-10000-09596	660 E D ST	90744	15	030B209   974	7424003035	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	33.77444	-118.25434	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7789	14041-20000-11407	16320 W ROSCOE BLVD	91406	6	192B137   317	2689023001	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.22111	-118.48785	TI FOR RECORDING STUDIO. NEW LIGHTING. EXISTING OFFICE SPACE. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7790	18041-10000-12169	3770 S WESTERN AVE	90018	8	117B193   523	5041034001	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	12/08/2020 12:00:00 AM	ADDRESS	34.01876	-118.30873	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A 7-ELEVEN. TOTAL AFFECTED AREA IS 15267 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7791	15041-10000-22130	1801 E 41ST PL STE B	90058	9	114A213   137	5116029059	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.00713	-118.24109	REMOVE EXISTING HID LIGHITNG FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7792	15041-10000-06804	2923 N ALLESANDRO ST	90039	13	150B213   792	5442025022	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.10472	-118.24587	in a warehouse, replacing HID luminaires with LED luminaires.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7793	17041-10005-37515	1400 N CAHUENGA BLVD	90028	13	147A187   280	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	34.09641	-118.32933	Change to an approved set by adding new ckts and equipment; Single line, floor plan and lighting plan being modified and updated with total load summary being recalculated. All changes under clouded area and associated to delta-(1,2,3,4,5,6,7, & 10).______________________________________________FULL PC FOR POWER AND ENERGY. NEW 8 STORY HOTEL WITH RESTAURANT AT GROUND FLOOR (CORE&SHELL ONLY) AND TOP LEVEL AMENITY WITH THREE SUBTERRANEAN GARAGE BASEMENTS.  SCOPE INCLUDES A NEW 2500A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 27,500 SQ. FT. B#16010-10000-05898	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7794	16041-20001-09542	5461 N YARMOUTH AVE	91316	5	174B129   960	2162010006	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.17054	-118.52046	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.3KW .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7795	18041-10000-43930	5555 W MANCHESTER AVE	90045	11	096B173   109	4127024029	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	33.96007	-118.37803	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7796	17041-20000-26736	11000 N NOBLE AVE	91345	7	210B145   362	2615011009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Re-Activate Permit	10/17/2018 12:00:00 AM	ADDRESS	34.26922	-118.45942	pv1install roof mounted pv system sized 5kw with (2) battery backup tesla powerwalls interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7797	19041-10000-17431	125 E 56TH ST	90011	9	108B205   753	5101015008	R2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.10	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Issued	05/09/2019 12:00:00 AM	ADDRESS	33.99166	-118.27309	NEW 6.1 KW ROOF MOUNTED PV SYSTEM WITH 20 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7798	12041-20000-25908	21031 W VENTURA BLVD # 307	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM			PC Approved	10/29/2012 12:00:00 AM	PIN	34.16717222	-118.59179488	Tenant Improvement.  Plan check for T-24 lighting only.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7799	17041-20000-34974	10100 W SANTA MONICA BLVD Ste 1250	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI to (E) commercial high-rise office space.  Plan check for energy.  2,233 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7800	18041-10000-19832	936 N MAHAR AVE	90744	15	033B213   675	7425039002	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	33.78335	-118.24607	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7801	14041-10001-05205	13114 W COMMUNITY ST	91352	6	192B161    50	2634027014	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.22323	-118.41848	Expedited plan check per applicant request.  (((PV1.  Install 3.5 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US-ZB-U.  15 modules: Trina Solar TSM-250PA05.18)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7802	10041-20000-07080	11811 W OLYMPIC BLVD	90025	11	123B149   409	4259023015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM			PC Approved	04/23/2010 12:00:00 AM	PIN	34.03353292	-118.45117088	INTERIOR TENANT IMPROVEMENT SCIENCE AND LIBRARY. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7803	16041-20002-42753	9182 N KELVIN AVE	91311	12	198B109   125	2748036008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Issued	02/27/2017 12:00:00 AM	ADDRESS	34.23802	-118.58526	(2/27/2017)changes to an approved set of plans.  change to divide system into two systems (1) single phase and (1) three phase to match existing field conditions.  Pv feedback breakers to tie into (1) 400 amp three phase service panel and (1) 200 amp  single phase panel. Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7804	18041-10000-12677	1500 N EL CENTRO AVE 2ND FLOOR	90028	13	147A189   234		(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.09917	-118.32359	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. ST. 5871 sqft. B#18016-10000-06780	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7805	18041-10000-28002	865 S FIGUEROA ST SUITE 2330	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT ON (E) SPACE #2330. INSTALL NEW LIGHTINGS AND RECEPTACLES USING EXISTING CIRCUITS. TOTAL AREA: 1,389 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7806	16041-20000-04867	4633 N CANOGA AVE	91364	3	166-5A107  10	2190016006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.15254	-118.59593	Plan check for a PV1 roof-mounted PV system. Addition of a 6 kWac system onto an existing 5 kWac for a total system size of 11 kWac. Addition consists of (1) inverter, (30) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7807	18041-20000-34473	12024 RICASOLI WAY	91326	12	216B109   373	2701084023	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Re-Activate Permit	03/04/2019 12:00:00 AM	PIN	34.29188411	-118.58500462	PV1.  Install 14.95 kW roof mounted grid tied PV system.  (46) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7808	16041-10000-26819	811 W WILSHIRE BLVD	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Closed	03/01/2018 12:00:00 AM	ADDRESS	34.04973	-118.2584	PC FOR POWER AND ENERGY UNDER PHASE I ONLY.  DUE TO DAMAGED EQUIPMENTS, REPLACING 4000A MS BOARD,  MAIN SWITCHGEAR , 1200A (MTMB)  AND 800A (EDS).  AFFECTED LIGHTING AREA 2067 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7809	19041-10000-46059	610 W ALPINE ST	90012	1	135A213   273	5407023008	R4-1	Central	Central City North	Historic Cultural North	YES	2071.02	Electrical	Electrical	Apartment			11/08/2019 12:00:00 AM			PC Approved	11/08/2019 12:00:00 AM	ADDRESS	34.06323	-118.24138	TENANT IMPROVEMENT IN THE COMMON AREAS OF THE 1ST FLOOR OF A COMMERCIAL BULDING. INSTALLING NEW LIGHTS IN 2 @ EXISTING RESTROOMS, MAIN LOBBY & TRAINING ROOM. T-24 ENERGY ONLY. AFFECTED AREA: 1,336 SFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7810	13041-10000-18894	5700 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.06218	-118.35303	TENANT IMPROVEMENT ; OFFICE BUILDING , SQUARE FOOT > 30,000 .  High rise buildinf 2nd floor TI --Tenant -- Clear channnel-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7811	15041-10000-24269	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Issued	09/09/2015 12:00:00 AM	ADDRESS	34.04338	-118.26581	Energy plan check for a courtside club of the Staples Center; Scope include new lighting, equipment, and receptacle. Total area is 2156-SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7812	11041-20000-00047	11999 W SAN VICENTE BLVD #345	90049	11	129B141   174	4404025029	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			01/03/2011 12:00:00 AM	01/03/2011 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.05246	-118.47261	Plan check T24 Energy (general/emegency) lighting for office TI #345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7813	17041-10000-03635	7921 N WOODLEY AVE	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.21438	-118.48393	PC for energy only outdoor title 24. Removing HID fixtures and replacing them with new  LED ones. Area: 15,200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7814	15041-10000-14198	6919 N ETON AVE	91303	3	183B105   783	2138016020	MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.19625	-118.59558	REMOVE HID LIGHT FIXTURES AND REPLACE WITH LEDS. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7815	16041-20000-21822	12510 W VANOWEN ST	91605	2	180B165    61	2325001005	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.19379	-118.40585	TI TO AN EXISTING COMMERCIAL BUILDING SINGLE STORY.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1118.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7816	11041-10003-09329	3663 W WILSHIRE BLVD Temple	90010	10	132B193    23	5503027016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Info Complete	05/30/2013 12:00:00 AM	ADDRESS	34.06188	-118.30486	Plan check for Delta 19 Revision. New 112.5KVA transformer and panel added to supply existing AC panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7817	18041-20000-21414	1537 N NORFOLK ST	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.06138	-118.20223	PLAN CHECK FOR ELECTRICAL SYSTEM UPPGRADE - SCOPE INCLUDES ADDING 2 NEW FUSE DISCOONECTS FOR ATS1&2, REPLACING BREAKERS ON 1000A DISTRIBUTION BOARD, 400A DISTRIBUTION BOARD REPLACEMENT & 225A PANEL INCLUDING ALL ASSOCIATED WIRING TO RE-FEED EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7818	17041-10000-34321	8803 S FIGUEROA ST	90003	8	096A201   156	6038006037	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.95717	-118.28299	PC FOR PV SYSTEM ON APARTMENTS. USING 50 MODULES CONECTED TO CENTRAL INVERTER. TOTAL RATING 11.4KW AC. DERATING MAIN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7819	14041-10000-23767	7755 N DEERING AVE	91304	3	189B105   468	2109030001	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.21187	-118.59678	PLAN CHECK FOR ENERGY ONLY FOR WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7820	18041-20000-44153	2492 N CHEREMOYA AVE	90068	4	154-5A189 484	5580005016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Apartment			11/19/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Issued	12/18/2018 12:00:00 AM	ADDRESS	34.11576	-118.3209	PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 8 MODULES (SW 325 XL MONO) AND 8  MICROINVERTERS..  SYSTEM SIZE IS 2.6KWdc and 2.24KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7821	15041-10001-26870	864 S VERMONT AVE	90005	10	132B197   748	5077024038	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.0563	-118.29145	A FIFTH STORY ADDED FOR FUTURE OFFICE TENANT AND OPEN PARKING; SERVICE UPGRADE TO 2500A; NEW CIRCUITS, 200A PANEL REDUCED THE NUMBER OF EV CHARGERS ; REPLACED 400A DIST BOARD WITH 600A BOARD TO ACCOMODATE NEW LOADS. REVISED TITLE 24 FORMSALL CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA 2 ((((((((NEW 4-STORY COMMERCIAL BLDG WITH RETAIL AND ABO.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7822	19041-10000-26368	1512 S WOOSTER ST	90035	5	129B169   455	4303002026	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.05154	-118.38291	T-24, outdoor lighting. Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only. Total affected area is 1000 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7823	15041-10000-37689	10501 S LA CIENEGA BLVD STE B	90045	11	090B173   386	4129036906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	33.94017	-118.37035	T24 only. remove HID light fixtures and replace with new LED fixtures. Total area 15840 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7824	13041-10000-29015	1103 S ABBOT KINNEY BLVD	90291	11	108B145  1025	4239022002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	33.99185	-118.47029	TITLE-24 , PART 6 ENERGY PLAN CHECK FOR LIGHTING. TENANT IMPROVEMENT IS FOR A COFFEE SHOP. ('BLUE BOTTLE COFFEE') .TOTAL LIGHTING AREA IS 610 SQ FT IN A SINGLE STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7825	18041-10001-21244	10250 W SANTA MONICA BLVD #2010	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Issued	06/26/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Change to an approved set by adding new ckts and modifying the floor plan. all changes under delta-4 only.(((FULL PLAN CHECK FOR  AN EXISTING  RESTAURANT T.I "" SUGAR FACTORY "")))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7826	19041-10000-22516	550 S HOPE ST # 400	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7827	15041-20000-21651	2111 N CAHUENGA BLVD BLDG 2	90068	4	151-5A187 288	5576003043	R3-1	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			09/11/2015 12:00:00 AM			PC Approved	03/16/2016 12:00:00 AM	ADDRESS	34.1091	-118.33132	Plan check for new 9 units Building 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7828	19041-20000-44062	16133 W VENTURA BLVD Ste. 850	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.15675	-118.4847	Plan check for Title 24 Energy only, new lighting in the space. Total area: 1689 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7829	19041-30000-46520	10923 W STRATHMORE DR 1-10	90024	5	135B149   229	4363005020	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.04	Electrical	Electrical	Apartment			11/12/2019 12:00:00 AM	04/15/2020 12:00:00 AM		Permit Finaled	08/29/2023 12:00:00 AM	ADDRESS	34.06779	-118.44976	PC FOR A NEW 1600A SERVICE THAT FEEDS AN 800A SECTION WHICH SUB FEEDS 21 SUBPANELS (DWELLING UNITS) AND THE 1600A SERVICE ALSO FEEDS A 1000A SECTION WHICH SUBFEEDS 4 ELEVATROS, AND VARIOUS HOUSE PANELS. TOTAL AFFECTED AREA IS 60,561 SQFT. PER BUILDING ((two new apartment buildings over shared 4 basement parking levels.  south buiding 5 stories above grade, north building 6 stories (5 stories Type III-A  Over Type 1-B Podium).B#17010-30000-04158))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7830	15041-20000-14445	1133 E 25TH ST	90011	9	118-5A211 141	5119007020	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.01944	-118.25333	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7831	17041-10003-24380	8420 N BALBOA BLVD STE 110	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Approved	05/14/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	"[This is plan check only, permit fee is covered under 17041-10000-24380]  Supplemental plan check for full plan check (power and energy) per inspector's request as this is a ""First Time Tenant"". There was an approved set of plan for T24 only under plan check# 17041-10000-24380 attached to this submittal. SOW: Install (2) 400A panelboards, and (1) 20A panelboard.Note: Permit fees are paid under PCIS#17041-10000-24380"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7832	16041-20000-19565	4608 W EL REPOSO DR	90065	14	162A219   304	5683034019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	06/11/2016 12:00:00 AM	PIN	34.13650447	-118.22569185	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4KW.  STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7833	15041-10000-10878	8500 S VERMONT AVE BLDG D	90044	8	097-5A199 185	6032013905	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			Corrections Issued	04/18/2015 12:00:00 AM	ADDRESS	33.96105	-118.29134	"NEW DEVELOPMENT 1600 AMP SERVICE, CORE AND SHELL,  PC FOR POWER AND ENERGY. THIS IS BULDING 'D' OF 7 BUILDINGS. TITLE 24 ENERGY CALCS FOR COMMON AREAS TO BE SUBMITTED AT A LATER TIME. ENERGY FEES ARE ESTIMATED BY BUILDING LOAD CALCULATIONS. (((PROPOSED  3-STORY RETAIL AND RESTAURANT BUILDING.THIS BUILDING IS KNOWN AS BLDG ""A""  TYPE VA W/ SPRINKLER SUBSTITUTION FOR FIRE RESISTANCE RATING. )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7834	14041-20000-23356	6545 N BELLINGHAM AVE	91606	2	180B165   453	2322005036	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.18987	-118.39886	PV1.  Install 4 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7835	12041-20000-02320	9013 N LANKERSHIM BLVD	91352	6	195B169   107	2631028021	C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.23335	-118.38803	Add 2 restrooms & corridor in existing storageEnergy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7836	12041-10000-17677	10359 N SEPULVEDA BLVD	91345	7	204B145   114	2649018001	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1097.00	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	34.25919	-118.46765	remodel building for a new autozone store	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7837	16041-10000-17609	203 S LOS ANGELES ST	90012	14	130-5A213 204	5161026901	C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.05021	-118.24366	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING 1-STORY LOS ANGELES LIBRARY. SCOPE INCLUDES 5 NEW OUTDOOR LIGHTING FIXTURES. TOTAL AFFECTED AREA IS 350 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7838	15041-20000-42538	10274 N BROOKE AVE	91311	12	204B101   177	2745001015	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	PIN	34.25695166	-118.60763048	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWdc/4.5KWdc.(18) MODULES-TIRNA SOLAR TSM-250 PD05.05(1)INVERTER-ABB PVI-3.8-OUTD-SUS-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7839	17041-10001-36540	6238 W 6TH ST	90048	5	135B177   394	5510026023	R2-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2017 12:00:00 AM			PC Approved	11/03/2017 12:00:00 AM	ADDRESS	34.06514	-118.36465	EXPEDITED FEESPV2, NEW ROOF MOUNTED SOLAR SYSTEM INTERCONNECTED WITH AN ENERGY STORAGE SYSTEM. (18) MODULES, (1) INVERTER5KWACC, (1)TESLA AC POWERWALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7840	17041-10000-11727	10250 W SANTA MONICA BLVD #1950	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR POWER AND ENERGY FOR FIRST TIME TI ""MICHAEL KORS""  IN WESTFIELD CENTURY CITY. SUITE 1950, TOTAL AREA 3,800SQ.FT"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7841	18041-10000-04078	2123 N VESTAL AVE	90026	13	144A211    20	5420018011	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.09075	-118.25134	Plan check for PV roof mounted system. Total system size: 8.5kW with 30 modules and 30 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7842	16041-20001-26826	12975 W JEFFERSON BLVD	90066	11	102B157    93	4211008026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	12/20/2016 12:00:00 AM	ADDRESS	33.97533	-118.42387	CHANGE TO POINT OF INTERCONNECTION FROM LINE SIDE TAP TO LOAD SIDE CONNECTION. NEW PANEL BOARD (SEPARATE PERMIT) WILL BE INSTALLED TO RELOCATE EXISTING BUILDING LOADS. modification to be filed rearding change	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7843	13041-10000-35762	1184 S CROCKER ST	90021	9	123A211    24	5132010044	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.03309	-118.25147	Title 24, removing two 400watts HID and replacing with fluo, three story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7844	12041-10002-27648	415 S LA BREA AVE	90036	4	135B181   536	5508006028	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.06635	-118.34436	((((CHANGES MADE TO APPROVED SET OF PLANS. CHANGE OF OVERHEAD TO UNDERGROUND PER LADWP 2000 A. NO OTHER CHANGES ORIGINAL PLAN CHECK IS FOR SHELL AND CORE , TENANAT TO BRING PLAN FOR THE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7845	19041-10000-15233	3335 S FIGUEROA ST STE E	90007	9	120A203   503	5123009042	[Q]C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.02224	-118.28008	PLAN CHECK FOR TITLE 24 ONLY. CHANGE OF USE FROM (E) MEDICAL OFFICE TO (N) OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7846	15041-20001-10692	10619 N GAVIOTA AVE	91344	12	207B141   511	2668007009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	34.26345	-118.4827	Expedite per applicant request*****Plan check for PV  adding new inverter and modules to  existing system. New systems are 1 inverter(PVI-5000-OUTD-US-Z-A) and 25 modules(KYOCERA # KU2606XPA) and new load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7847	10041-20000-05732	145 S SPRING ST 8th floor	90012	14	130-5A213  30	5149001003	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM			PC Approved	03/30/2010 12:00:00 AM	ADDRESS	34.05196	-118.24563	Lighing and power on portion of  8th floor of highrise building. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7848	16041-20000-35854	9030 S LOYOLA BLVD	90045	11	096B161   819	4119039002	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.95663	-118.41787	PLANCHECK FOR POWER ONLY. INSTALLATION OF A NEW TRANSFORMER AND EV CHARGERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7849	18041-10000-13272	3435 W WILSHIRE BLVD 14th floor	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Info Complete	04/11/2018 12:00:00 AM	ADDRESS	34.06194	-118.29866	T-24, PC FOR ENERGY ONLY.  TI FOR AN EXISTING OFFICE SPACE ON THE 14TH FLOOR. TOTAL AFFECTED AREA IS 19680 SQ. FT.  B#18016-10000-08827	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7850	16041-10000-43629	1243 S SANTEE ST	90015	14	124-5A209 144	5145028018	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.03542	-118.25828	T-24, PC for energy only. Remove exterior HID fixtures and replace with new LED fixturse. Total sqft = 43060	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7851	18041-20001-28098	7001 S SEPULVEDA BLVD	90045										Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM			PC Approved	08/13/2018 12:00:00 AM	ADDRESS	33.97667	-118.39439	expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7852	13041-20000-32164	9201 N VANALDEN AVE	91324	12	198B121   642	2762035018	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Expired	12/11/2015 12:00:00 AM	ADDRESS	34.23728	-118.54932	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.5 KW AC USING 30 MICROINVERTERS. ENPHASE M215. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7853	15041-20000-02607	12150 N MEMPHIS AVE	91342	7	216B149   234	2611014013	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.29057	-118.45298	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.521 KW(23) SUNPOWER MODULES(1) POWER ONE 3(1) POWER ONE 4.2	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7854	18041-10002-04678	13755 W BAYLISS ROAD	90049	11	138B133    22	4492015016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.07848	-118.50687	PC for 5kW Tesla battery in PV solar system(18041-10000-04678).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7855	16041-10004-45686	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.01303	-118.24279	DELTA 12 CHANGES TO APPROVED SET OF PLANINCREASE SIZE OF CONDUCTORS AND RECALCULATED VOLTAGE DROPS AND AVAILABLE SHORT CIRCUIT CURRENTPLAN CHECK ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7856	17041-10000-30401	1346 S ABBOT KINNEY BLVD	90291	11	108B145  1373	4238004036	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Info Complete	09/27/2017 12:00:00 AM	ADDRESS	33.99066	-118.46652	PC FOR POWER AND ENERGY FOR A MIXED USED TI. BUILDING OCCUPIED BY ONE TENANT .FIRST FLOOR SALON AND SECOND FLOOR RESEDINTIAL. SCOPE INCLUDES NEW PANELS ,CIRCUITS, LIGHTS & EQUIPMENT.B# 16016-10000-25230	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7857	12041-20000-17751	7370 W SUNSET BLVD	90046	4	147B181  1148	5550021001	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.09785	-118.35128	New fire alarm system for hotel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7858	12041-20001-15331	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			Reviewed by Supervisor	06/12/2013 12:00:00 AM	ADDRESS	34.2215	-118.42999	(((changes to approved set of plans. clouded changes in blue ink. change fixtures type from flourescent to LED. data sheets will be provided. wattage changes reflected on t24 LTG forms. all locations of fixtures to remain and controls from previuos approved set. plan check for energy only, clouded changes. this is plan check only. no permit to be issued from this application. built in sensor in fixtures for shut off control. continous dimming for multilevel control.  )))))Alteration to existing medical office building on basement, first, second, and third floors.  Remove the existing light fixutres and replace with new light fixtures.  All new light fixtures reconnect to existing branch circuits.  No new branch circuits, receptacles, and wiring are added or changed.  Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7859	11041-20000-13164	20014 W VENTURA BLVD	91364	3	174B113   460	2166001003	C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	10/05/2011 12:00:00 AM	ADDRESS	34.17152	-118.56887	ENERGY PLAN CHECK JUICE BAR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7860	19041-10000-30846	2935 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	12/23/2021 12:00:00 AM	ADDRESS	34.10427	-118.24362	PLAN CHECK FOR 1200 AMP NEW SERVICE AND PANELS FOR 30 SMALL LOT SUBDIVISION SINGLE FAMILY DWELINGS. 4 APPLICATIONS UNDER 1 SET OF PLAN.(4 OF 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7861	18041-10000-46960	10877 W WILSHIRE BLVD	90024	5	132B153   297	4360003029	[Q]C4-3-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/10/2019 12:00:00 AM		Issued	12/10/2019 12:00:00 AM	ADDRESS	34.05934	-118.44254	PC FOR FA SYSTEM. SCOPE INCLUDES 1052 DEVICES AND 4 PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7862	18041-10001-12866	1301 S OCEAN FRONT WALK #17	90291	11	108A143   398	4226006001	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Info Complete	05/08/2018 12:00:00 AM	ADDRESS	33.98842	-118.47485	DELTA 1 CHANGES TO APPROVED PLANS. TI IN AN EXISTING RESTUARANT. EPC FOR POWER ONLY PER INSPECTOR'S REQUEST.ELECTRICAL PERMIT WAS ISSUED ON 18041-10000-08510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7863	17041-10000-02950	1017-1025 N SYCAMORE AVE	90038	4	144B181   570	5531014012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.08945	-118.34292	FULL PC FOR  EXISTING MEDIA PRODUCTION BUILDING. SCOPE INCLUDES A NEW 800A 120/240 3 PHASE, 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 17026 SQ. FT. B#17014-10000-00180	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7864	17041-10002-25740	4151 W PROSPECT AVE BLDG G	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC in Progress	06/22/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	"DELTA ""1"" CHANGES ONLY TO UPDATE PLANS TO MATCH THE EXISTING CONDITIONS AND ADDRESS SOME CORRECTIONS PER INSPECTOR'S REQUEST.PLAN CHECK ONLY, PERMIT UNDER MASTER APPLICATION. <<<PC FOR POWER RPLACING TWO SWITCH BOARDS 800 AND 1600 AMPS  240V WORK DONE IN  BUILDING  ""G""  STAGES ONE AND TWOSCOPE INCLUDES  REPLACING EQUIPMENT AND INSTALLING NEW CIRCUITS>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7865	18041-10000-29635	9350 N RESEDA BLVD	91324	12	198B125   168	2764011029	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.24046	-118.53589	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7866	14041-10000-33348	19524 W NORDHOFF ST	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.23527	-118.55871	Full plan check for a medical office change to a dental office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7867	16041-10000-10336	4000 S FIGUEROA ST	90037	9	115-5A201 112	5019026001	C2-1L	South Los Angeles	Southeast Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	34.01082	-118.28253	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS BUILDING. SCOPE INCLUDES REPLACING LIGHTING FIXTURES WITH LEDS. TOTAL AFFECTED AREA IS 1686 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7868	18041-10000-43614	3415 S SEPULVEDA BLVD	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Issued	11/16/2018 12:00:00 AM	ADDRESS	34.02055	-118.42347	T-24 only for a ELevator area	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7869	14041-10001-16143	2644 E ROSEVIEW AVE PV2	90065	1	145-5A217  90	5453003054	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.09342	-118.22769	(((8/15/2014 - Supp. app. for plan check for roof mounted solar PV array at request of inspector.  Plan was originally submitted to express permit.  Main service panel is 600A. Type changed to apartment. PLAN CHECK ONLY)))Master permit work description: INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 2.04KW. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7870	11041-20000-13093	11601 W WILSHIRE BLVD #1525	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	10/21/2011 12:00:00 AM	PIN	34.0509267	-118.45996763	energy plan check 1525	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7871	15041-10001-02441	16451 W SHADOW MOUNTAIN DR	90272	11	132B121    24	4420037007	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM			PC Approved	02/06/2015 12:00:00 AM	ADDRESS	34.06141	-118.54208	Expedite plan check per applicant request(((((Plan check for PV1 rooftop mounted with 10kW  STC. 36 modules and 36 micro-inverters.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7872	13041-10000-26290	11151 N BERTRAND AVE	91344	12	210B125   232	2715020037	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South	YES	1112.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.2736	-118.52563	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200A MAIN IN A 1-STORY HOUSE. WORK DONE ON A CENTRAL INVERTER-STANDARD PLAN, WITH COMBINER BOX. SYSTEM SIZE IS 11KW DC WITH (44) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG PLUS V 10	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7873	15041-10000-00823	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.17307	-118.59314	PLAN CHECK FOR FIRE ALARM. INSTALL NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7874	15041-20000-31580	4902 N TOPANGA CANYON BLVD	91364	3	168B101   467	2171016044	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.15713	-118.60561	TI to existing commercial building (restaurant). Plan check for energy only. Adding new lighting including emergency. Total sqft. 1,037.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7875	16041-20001-26771	421 N HELIOTROPE DR 1-60	90004	13	141B197  1173	5520016022	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.07839	-118.29606	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on an Apartment building. Interconnect with a 400A MSP. Derating main breaker from 400A to 250A. 40kW ungrounded system [4*10kW]. (176) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7876	18041-20002-38365	533 E DOLORES ST pv1	90744	15	036B209   221	7422025022	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM			PC Approved	10/19/2018 12:00:00 AM	ADDRESS	33.79446	-118.25702	10-19-2018 Changes to an approved set of plan, changes include relocate LG battery and disconnect for PV. Changes has been cluded. Plan check only. Fees $0 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7877	14041-20000-14624	7301 N DARNOCH WAY	91307	12	186B089   633	2027020022	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.20329	-118.64469	7.5KW roof-mounted system with (30) Canadian Solar modules( CS6P-250PX) , (30) Solaredge Powerbox Optimizer and (1) Solaredge transformerless inverter (#SE6000A-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7878	14041-10000-14634	12800 W VENTURA BLVD	91604	2	165B161  1067	2384016046	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.14462	-118.41177	"PC FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR EXISTING ""PETCO"" RETAIL;BUILDING APPLICATION # 14016-10000-10578."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7879	17041-10001-17657	3234 S KELTON AVE	90034	5	120B157   352	4254018012	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.02649	-118.41994	PC only.  Changes to approved set.  Change system from 4 strings to 3 strings (total number of modules to remain the same).  Revise AC disconnect to show it is not part of rapid shut down system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7880	13041-10000-33012	2402 N EDGEWATER TER	90039	4	148-5A209 307	5439014017	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.10091	-118.26022	PV1. ROOFMOUNTED PHOTOVOLTAIC SYSTEM INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 4.5KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(18) TRINA SOLAR # TSM-250(18) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE5000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7881	14041-10000-06431	1000 W ELYSIAN PARK AVE 76 STATION	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	Restroom remodel at 76 station on Dodger Stadium lot.  Title 24 plan check only for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7882	17041-20002-26375	12415 N RALSTON AVE	91342	7	219B149   618	2507006020	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.29588	-118.45099	[[[12/1/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING TO ENPHASE IQ6-60-2-US MICROINVERTERS]]]Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (60) modules, (60) micro-inverters, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7883	19041-10000-53837	680 S MYERS ST	90023	14	124-5A219 182	5171021015	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.03537	-118.22504	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7884	19041-10000-31826	3770 W SANTA ROSALIA DR	90008	8	114B185   329	5032019011	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	34.01	-118.3397	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7885	16041-10000-20296	5824 S MEADOWLARK PL	90094	11	102B161  1272	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	33.9752	-118.4156	Install F.A  (1) FA panel,   (75) devices    (1) comm. panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7886	12041-20000-01336	261 S 26TH ST	90049	11	129B137   570	4264001011	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Info Complete	02/28/2012 12:00:00 AM	PIN	34.04710418	-118.49004065	Remodel of existing space for retail store.  Tailored method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7887	17041-10005-04779	6821 S VICTORIA AVE	90043	8	102B185   577	4006023004	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Info Complete	01/04/2019 12:00:00 AM	ADDRESS	33.97624	-118.33248	DELTA 4 changes to approved plans for changing the size of the feeder from 1/0 to #1AWG.<<<<Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 800 amps and new distribution equipment only. No load is included as part of this scope of work.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7888	12041-10000-09137	4335 S WOODLAWN AVE #3,9	90011	9	114A205   449	5113036015	C2-1VL	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Expired	07/11/2014 12:00:00 AM	ADDRESS	34.00457	-118.27303	Plan check for apartment bldg. PV system, 18.56 KW, roof-mounted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7889	16041-10001-09344	8204 N SUNLAND BLVD	91352	2	192B173   759	2407023044	[Q]C2-1VL-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Expired	06/27/2018 12:00:00 AM	ADDRESS	34.21951	-118.36842	PC for Power only per inspector field correction. Scope of work is TI to an (E) restaurant due to fire damage. This is supplemental to express permit# 16041-10000-09344	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7890	19041-10000-03533	8148 N DE GARMO AVE	91352	2	192B177   953	2407022011	RD2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Apartment			01/29/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Issued	01/30/2019 12:00:00 AM	ADDRESS	34.21847	-118.35681	PC FOR PV SYSTEM. 15 JINKO 270 WATT - 1 STRING. 1 CENTRAL INVERTER FRONUIS PRIMO 3.8. 1 NEW PANEL UPGRADE TO 100AMP BUS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7891	17041-20000-43067	20410 W VIA BOTTICELLI	91326	12	219B109   223	2701059005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Closed	08/31/2023 12:00:00 AM	ADDRESS	34.29833	-118.57866	PV1.  Install 6.6 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7892	13041-20000-08112	1542 N TOWER GROVE DR	90210	5	147B157   255	4356019012	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.09821	-118.42574	Addition to a single family dwelling.  Upgrade the electrical service to 800A.  Install new main switchboard, subpanels, and branch circuits.  Install new 100KW Optional Standby Generator.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7893	17041-10000-02609	5560 W THORNBURN ST	90045	11	102B173   358	4103005038	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.97371	-118.3775	PC for title 24. Outdoor. Remove HID fixtures and replace with new LED fixtures. Area: 33,175.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7894	16041-10000-45002	10250 W SANTA MONICA BLVD UNIT 1820	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER AND ENERGY FOR BONOBOS - SUITE 1820 - BUILD OUT OF RETAIL TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7895	16041-20000-32840	18957 W CARMEL CREST DR	91356	3	162B121   162	2177048014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM			Plans on Hold	10/04/2016 12:00:00 AM	ADDRESS	34.14115	-118.5437	BATTERY STORAGE SYSTEM  + PV1 ROOFMOUNTED SOLAR SYSTEM.  SYSTEM SIZE: 7.6KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7896	17041-20000-45615	19430 W COHASSET ST	91335	3	186B117   427	2116016063	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.20644	-118.55669	pv1install roof mounted pv system sized 17.9kw interconnected with msp.efficiency 16.64kw ACNote: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7897	17041-20000-23568	6100 W CENTER DR 1225	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	33.97733	-118.3922	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. SUITE 1225 . 4,176 SF Building p # 17016-10000-16633	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7898	17041-10000-10086	12153 N MISSION RIDGE WAY	91344	12	216B129    34	2608033009	RE15-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.29245	-118.51648	PV1, INSTALLATION OF A NEW 11.39 KWdc / 10.88KWac ROOF-MOUNTED SOLAR SYSTEM ON A RESIDENTIAL HOUSE.(34) SUNPOWE SPR-X21-335-WHT-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7899	19041-10000-24186	6605 S OCEAN FRONT WALK	90293	11	096B149   322	4116002047	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	33.95981	-118.45206	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND TESLA SOLAR ROOF MODULES, (98) ROOF MODULES (1)7.6 KW INVERTER. TOTAL SYSTEM SIZE IS 6.7925 KWDC AND 7.6 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7900	14041-20000-01199	13545 W VAN NUYS BLVD	91331	7	207B157   883	2619026029	[Q]C2-1VL-O-CDO, [Q]P-1-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.26169	-118.42854	PLAN CHECK ONLY for Energy, with Emergency lighting.  Change to lighting, new receptacles, new HVAC in an existing low-rise office building.  Load is 373.1 amps per the plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7901	19041-20004-19099	13262 W GALEWOOD ST	91423	4	162B157   331	2385006034	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.14224	-118.42152	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO PV SOLAR ROOF TILE SPECIFICATIONS. INCREASE TO PV DC SYSTEM SIZE FROM 27.8435 KW TO 27.94866 KW. CHANGES MADE TO COVER SHEET AND SINGLE LINE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7902	18041-10000-40824	9920 S HOOVER ST	90044	8	091-5A201  94	6054022001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	33.94576	-118.28678	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7903	15041-20000-30907	1601 N HOBART BLVD 1-54	90027	13	148-5A195 289	5544020010	[Q]R4-2	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			09/18/2015 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.09995	-118.30593	PLANCHECK FOR POWER AND ENERGY. NEW 54 UNIT FOUR (4) STORY LEVEL RESIDENTIAL APARTMENT BUILDING (SUBTERRANEAN PARKING, COMMUNITY ROOM & OFFICE.  BUILDING SUBMITTAL ON 2008 CODE.; 13010-10000-04281. FIRE ALARM VARIANCE HAS BEEN SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7904	19041-20000-15106	1128 S LOS ANGELES ST	90015	14	126A209   299	5145021004	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM			Corrections Issued	04/24/2019 12:00:00 AM	ADDRESS	34.03751	-118.25762	REPAIR OF FIRE DAMAGED RETAIL/WAREHOUSE BUILDING. REBUILD/REPLACE ELECTRICAL SYSTEM. PC FOR T24 ENERGY ONLY. TOTAL SQUARE FOOTAGE = 6,458SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7905	16041-20000-04985	1525 N GOWER ST	90028	13	148-5A189 303	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.09849	-118.32256	Full plan check for First Time tenant  1st and 2nd floor. Total area: 9,040 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7906	15041-10008-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET UNDER DELTA 40.TITLE -24 ENERGY ONLY.INCLUDES: 1.ADDITION OF 1200 SQ.FT AND 800W OF LIGHTING LOAD.2. CHANGES TO  FIXTURE COUNTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7907	12041-10000-28413	14820 W PAMPAS RICAS BLVD	90272	11	126B129   578	4411014008	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2627.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	ADDRESS	34.0407	-118.519	tHIS IS ROOF MOUNTED MICRO INVERTER, ONE COMBINER BOX, 58 MODULES AND 58 INVERTERS, ONE CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7908	18041-10000-17184	5927 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	05/11/2020 12:00:00 AM		Permit Closed	02/17/2022 12:00:00 AM	ADDRESS	33.93319	-118.38745	PLAN CHECK  FOR NEW FUEL CELL  AND ASSOCIATED EQUIPMENT. SYSTEM CONSIST OF 2 FUELCELLS(252 AMPS), WITH 1200A DISTRIBUTION BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7909	18041-20000-36237	15350 W SUTTON ST	91403	5	166-5A145 143	2283021019	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Issued	09/21/2018 12:00:00 AM	ADDRESS	34.15009	-118.46929	Plan check for a PV1 roof-mounted PV system. System size is 5.8 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7910	15041-20000-23765	17536 W SAN JOSE ST	91344	12	207B129   923	2733015015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.26104	-118.51669	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (38) modules, and (1) combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7911	16041-20000-15161	4700 W SUNSET BLVD	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Expired	06/13/2018 12:00:00 AM	ADDRESS	34.09788	-118.29194	PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORT.  28355 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7912	14041-20000-10451	6820 W ROMAINE ST	90038	4	144B185   975	5532012026	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM			PC Info Complete	06/17/2015 12:00:00 AM	ADDRESS	34.08879	-118.33925	PC FOR POWER ONLY. NEW 1600A SERVICE IN EXISTING MANUFACTURING. RECONNECT EXISTING LOADS. PROJECTED INCREASE IN LOADS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7913	17041-10000-08897	900 W WILSHIRE BLVD 25TH FLR	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Issued	08/30/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	Interior TI to core & shell open office space on the 25th floor (appro. 24000 SF) to include new 5' wide rated corridor for open office space for future tenants. See comments.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7914	13041-10001-31545	18736 W LULL ST	91335	3	186B121    95	2103016031	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.20921	-118.54189	Expedited RSES plan check per applicant request.(((PV1, Install 6.5 kW DC roof-mounted solar array for 1-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 26 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7915	13041-20002-06131	17943 W CHATSWORTH ST	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.26501	-118.52499	((DELTA 5 CHANGES MADE TO APPROVED SET OF PLANS. CHANGES TO POWER AND ENERGY))New tenant (Pieology) in core and shell building of a single story building.  Install a new subpanel and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7916	18041-20001-02689	9451 N CORBIN AVE	91324	12	198B117    68	2761040016	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.24147	-118.56249	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF LIGHTING TO LAYOUT. TOTAL AFFECTED AREA 8238 SQ. FT. ORIGINAL PERMITPLAN CHECK FOR TITLE 24 ONLY FOR T. I. TO (E) OFFICE. TOTAL AFFECTED AREA = 7358 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7917	13041-20000-22099	18052 W RAYEN ST	91325	12	195B125   461	2768009004	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.23173	-118.52695	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.105 KW. 29 MODULES AND 1 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7918	17041-30001-21160	401 N FIGUEROA ST 401	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	33.77372	-118.27881	SUPPLEMENTAL# 17041-30000-21160  (2) BRANCH CIRCUITS (LIFT/AC),  (1) A/C,  (2) OUTLET SWITCHE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7919	19041-20000-20227	1556 S HI POINT ST	90035	10	129B173   999	5068018065	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			05/29/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	08/02/2021 12:00:00 AM	ADDRESS	34.04835	-118.36946	2000A 208Y/120V 3ph-4w service, distribution, power, and lighting for new building.  Plan check for power and energy.  Associated building permit under 16010-20000-02390.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7920	14041-10000-13763	1828 E CESAR E CHAVEZ AVE	90033	14	130-5A221 325	5174008022	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.05014	-118.21571	Full plan check for existing medical center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7921	11041-10000-03585	850 S BROADWAY	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	09/20/2011 12:00:00 AM	ADDRESS	34.04248	-118.25568	TO REPLACE EXISTING 1000 AMPS SERVICE WITHE 1000 AMPS SERVICE DUE TO RUSTY EQUIPMENT. RESTAURANT IS FUTURE TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7922	12041-10000-19032	15630 W VENTURA BLVD	91436	5	168B141   685	2283006001	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Issued	08/14/2012 12:00:00 AM	ADDRESS	34.15484	-118.47446	New fire alarm for a new commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7923	19041-10000-18955	1719 W 265TH ST	90710	15	030B193    89	7411028027	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	33.78102	-118.30771	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 17 MODULES (LG320N1K-A5) , 17 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 5.44KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7924	14041-10000-17600	550 S HOPE ST FLOOR 20	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT.  OFFICES.  NO CHANGE IN USE, 2215 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7925	15041-10000-25377	3620 S MCCLINTOCK AVE 4TH FLOOR	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.0213	-118.28935	PC FOR ENERGY ONLY FOR USC SGM BLDG OFFICE AREA ONLY 1300 SQ FT. SCOPE OF WORK IS IN 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7926	15041-30000-32732	17278 W SUNDERLAND DR	91344	12	216B133   153	2606009023	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Expired	10/27/2017 12:00:00 AM	ADDRESS	34.29074	-118.51021	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (25) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7927	15041-10000-40544	6602 W SELMA AVE	90028	13	148-5A185 281	5547018002	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.09959	-118.33326	T-24, CHANGE OF USE FROM RESIDENTIAL TO OFFICE SPACE. SERVICE SIZE IS 400AMP, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING ONLY. TOTAL SQ. FT. 3800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7928	16041-10001-13870	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	12/06/16Changes to an approved set of plans. All changes are clouded under delta 3, 4 , and 5. Changes include removing load on panelboards, adding/relocating new circuits/lights, adding one new panel, new transformer, revising single line diagram, and revising floor plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7929	16041-10000-30995	1000 W 8TH ST	90017	14	129A207    78	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.04866	-118.26309	PLAN CHECK FOR POWER AND ENERGY FOR BLD R3,  A HIGH RISE MIXED USE, RETAIL, PARKING, AND RESIDENTIAL BUILDINGS (TOWER 3 (BLD R3) PART 2 OF 2). NEW RESIDENTIAL TENANT SPACES GROUND FLOORS, LEVEL 26 THROUGH LEVEL 59(APPLICATION FOR FLOORS GROUND TO 25 IS ON A SEPARATE APPLICATION, BUT THE PLANS FOR BOTH APPLICATIONS IS ONLY ONE SET OF PLANS). TOTAL AFFECTED AREA IS 98,009 SQ. ORIGINAL CORE/SHELL APPLICATION COVERS BUILDING R2 AND R3. FT. b#15016-10000-26070	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7930	12041-20000-00840	12269 W MONTAGUE ST	91331	7	204B165   166	2537003050	[T][Q]M1-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM	01/12/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.25561	-118.40066	energy plan check food prep	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7931	19041-10001-10213	802 S FRIES AVE	90744	15	024B205    34	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	33.76172	-118.26356	Collecting additinal plan check fees for 19041-10000-10213. Permit fees will be cancelled. <<<<PC for power only. Replacement of a 4160V switchgear/service and replacing two unit substations with other associated ckts connecting to existing load.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7932	19041-20001-00479	1225 N EL CENTRO AVE	90038	13	144B189   270	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.09329	-118.32459	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 107.1 kWdc/79.8 kWac and consists of (7) inverters, (306) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7933	10041-10001-02157	4810 W SUNSET BLVD	90027	13	147B197   737	5543017018	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	06/15/2011 12:00:00 AM	ADDRESS	34.09792	-118.29436	4 story bldg , church.1 panel and 185 device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7934	17041-10001-04025	310 N MADISON AVE	90004	13	138B197   243	5501002034	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.0768	-118.28902	CHANGES TO AN APPROVED SET OF PLANS. SCOPE OF WORK INCLUDES CHANGES TO REFLECT THE FIELD. PC ONLY.PC for energy only for TI for new offices. Total affected area is 13772 sqft. Installed load under 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7935	14041-10000-33437	23130 W VICTORY BLVD	91367	3	180B093   907	2039012020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.18623	-118.631	PV1 ROOF MOUNTED SYSTEM WITH SYSTEM SIZE: 7.6KW AND 4 STRINGS WITH 2 INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7936	09041-10003-13631	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	Change of UPS from 15 to 20 kva. approval does not iclude tapping to 2000 amps bus. To be field evaluated by mr. Tim Moore.((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((()))))))))))))))))))))))))))))))))))))))))))))))))))))))NEW CHANGES ARE MADE TO ... RFIS , ADDITION OF EQUIPMENT IN PANELS WITH 480/277 VOLTS , ADDITION OF EXIT SIGNS CKTS , REPLACE OCCUPANCY SENSSORS, RE CKT LIGHTING IN BATHROOMS. EXAUST FANS,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7937	16041-10001-17609	203 S LOS ANGELES ST	90012	14	130-5A213 204	5161026901	C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.05021	-118.24366	08/04/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include replacing an exterior lighting fixture with a sign light. (((((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING 1-STORY LOS ANGELES LIBRARY. SCOPE INCLUDES 5 NEW OUTDOOR LIGHTING FIXTURES. TOTAL AFFECTED AREA IS 350 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7938	16041-20000-23236	326 S LINCOLN BLVD A-B	90291	11	111B145   656	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.00097	-118.46668	PLANCHECK FOR POWER AND ENERGY.  FIRST TIME TENANT. RESTAURANT.  CAVA GRILL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7939	16041-10001-18790	617 N DILLON ST 1-49	90026	13	141A203   375	5401014013	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM			PC Approved	05/01/2019 12:00:00 AM	ADDRESS	34.07899	-118.27903	THIS IS PLAN CHECK ONLY FOR CHANGES TO APPROVED SET UNDER DELTA 5 ONLY. SCOPE INCLUDES UPDATING INDOOR AND OUTDOOR  SQ.FT AREAS TO REFLECT FIELD CONDITIONS. INCLUDING ROUTING OF LIGHTING CIRCUIT TO THE INVERTER AND INTERGRAL OCC. SENSORS IN PARKING. THIS IS PLAN CHECK ONLY PERMIT UNDER MASTE.R.Full PC for a new four story 49 unit apartment with subterreanean parking. Located in a methane zone area.  New 2500 Amp service 120/208 U.G.P.S. It includes 29 typical units. Total sqft = 40,517.*** plan checker to verify the number of circuits for submittal 2 fees (adjustments were made for a pre-made check payment)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7940	18041-10000-07922	10207 N BALBOA BLVD	91325	12	204B133   312	2694001039	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Issued	10/18/2018 12:00:00 AM	ADDRESS	34.25571	-118.50266	"Plan check for T24 only, ""Energy Reduction Project"" for Chase Bank. Replace indoor and outdoor luminaires to LED fixtures using existing circuits. Total area: 6696 sq.ft indoor + 17494 sq.ft outdoor"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7941	14041-10001-11534	8222 N TYRONE AVE	91402	6	192B153   924	2212016018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.22042	-118.44412	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7942	10041-20000-23831	8723 W ALDEN DR 3RD FL	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	10/12/2011 12:00:00 AM	ADDRESS	34.0754	-118.38272	REVISION DELTA 4 FOR 23 ADDITIONAL CIRCUITS TO EXISTING PERMIT AT STEVEN SPIELBERG BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7943	14041-20001-18291	459 N SURFVIEW DR	90272	11	129B113    12	4443020002	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM			Corrections Issued	07/12/2014 12:00:00 AM	ADDRESS	34.04917	-118.56729	EXPEDITE FEESPV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 10.5 KW AC / 12KW DC. USING 44 MODULES. USING MICROINVERTER SYSTEM. NONSTANDARD PLAN. ENPHASE M250.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7944	19041-10000-26085	725 N CROFT AVE	90069	5	141B173   380	5528001043	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	07/20/2020 12:00:00 AM		Permit Finaled	10/14/2022 12:00:00 AM	ADDRESS	34.08433	-118.37448	FULL PLAN CHECK FOR A NEW 4 STORY, 31 UNIT, TWO APARTMENT BUILDINGS WITH ROOF DECKS OVER 1 LEVEL, TYPE IA SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES NEW 2000A 208/120 3� 4W SERVICE WITH A 125KVA BACKUP GENERATOR.FIRE VARIANCE TO SEPERATE FIRE ALARM PLANS HAS BEEN SUBMITTED.B#18010-10000-06099	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7945	13041-20000-31874	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	PC FOR T24 ENERGY ONLY. NEW LIGHITNG. SMALL HAIR SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7946	16041-20002-45443	5010 N PALOMAR DR	91356	3	171B117   547	2175004007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2017 12:00:00 AM			PC Approved	05/01/2017 12:00:00 AM	ADDRESS	34.16137	-118.55328	Revisions to approved set of plans.  Additional 600A subpanel, all building loads relocated from MSP to subpanel.  (((PV1.  Install 27.525 kW AC roof mounted grid tied PV system.  (95) modules with Enphase S280 microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7947	12041-20000-09554	16661 W VENTURA BLVD	91436	5	168B137   270	2259011034	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM			Corrections Issued	04/26/2012 12:00:00 AM	ADDRESS	34.15837	-118.49645	Plan check for energy. 1626 conditioned sqft. High-rise commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7948	15041-20000-15261	171 N FULLER AVE	90036	5	138B181   502	5512014004	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.07559	-118.34994	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7949	16041-20000-20665	8436 W 3RD ST #603-604	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.07301	-118.37448	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 564 sq. ft.Note: Building application has been generated under 16016-20000-09325	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7950	12041-20000-14798	9618 W PICO BLVD 504	90035	5	132A167   261	4306001037	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Approved	06/28/2012 12:00:00 AM	ADDRESS	34.05496	-118.39815	T-24  lighting plan check for alteration to existing space 504.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7951	16041-10002-20288	5820 S 3RD AVE	90043	8	108B189  1483	4005022006	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	33.98851	-118.32045	06/28/2016Changes to an approved set of plans, changes include the relocation of PV equipment. (((PV1, rooftop solar instllation 4.125 kW AC system.   (15) SW275,   (15) M250 Enphase)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7952	14041-20000-00558	5373 N BLANCO AVE	91367	3	171B089    54	2047015022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.16836	-118.65279	PV1 CENTRAL INVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 7.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7953	18041-20000-35942	1011 N MAYBROOK DR	90210	5	144B157   319	4358013034	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	12/30/2020 12:00:00 AM	ADDRESS	34.09001	-118.43014	600 amp service upgrade.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7954	14041-20000-04856	20500 W BLAIRMOORE ST	91311	12	207B109   501	2707012051	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.26242	-118.58012	Roof mounted PV system with optimizer.  System size is 4KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7955	11041-20000-23628	2122 W WASHINGTON BLVD	90018	10	126B193   942	5074033012	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/07/2011 12:00:00 AM	ADDRESS	34.03974	-118.30674	T.I.  Remodel of the light fixtures for a commercial space (charity).  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7956	12041-10000-02087	2203 S GRAND AVE	90731	15	009B197    74	7465001012	RD1.5-1XL	Harbor	San Pedro	Coastal San Pedro		2972.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	33.72406	-118.29034	New 8.46 kw rooftop, photovoltaic system for an existing single family residence.  Upgraded 225 amp panel, no change to service or main breaker size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7957	18041-20001-09190	21789 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	01/05/2024 12:00:00 AM	ADDRESS	34.16857	-118.60252	10/01/2018 Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 773 sq. ft.Note: Building permit has been issued under 17016-20000-28932*****Previous Work Description*****INSTALL DROP DOWN LIGHTS AND CAN LIGHTS ON EXISTING CIRCUITS. OK PER ELECTRIC PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7958	16041-20000-45607	11755 W WILSHIRE BLVD 24th flr	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	PIN	34.04869377	-118.46238681	ti to an existing building high rise.  adding new lighitng new controls to existing panels.  plan check for energy only total square footage 1289.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7959	10041-10000-17621	1700 E CESAR E CHAVEZ AVE	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2035.00	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	03/08/2011 12:00:00 AM	ADDRESS	34.05093	-118.21753	Ti in a doctor office.Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7960	13041-10000-31996	5207 N MT ROYAL DR	90041	14	163-5A225 220	5669019027	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.14171	-118.20372	PV1 , ROOF-MOUNTED MICROINVERTER SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN. SYSTEM SIZE IS 4.32kW AC WITH (20) WINAICO WSP-260P6, (20) ENPHASE M215 MICROINVERTERS. LOAD CENTER WILL BE USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7961	14041-10000-34357	14006 W RIVERSIDE DR # FC-9	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	TENANT IMPROVEMENT OF EXISTING RESTAURANT AT THE MALL FOOD COURTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7962	16041-10000-16234	14434 W SHERMAN WAY	91405	6	183B149   101	2217007053	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.20103	-118.44763	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW DIALYSIS CLINIC. SCOPE INCLUDES 84 FA DEVICES, 1 FA PANEL, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7963	16041-20000-26778	450 S ST ANDREWS PL	90020	4	135B193   629	5503016080	R4-1	Central	Wilshire	Greater Wilshire		2117.03	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.06561	-118.31141	Plan check for PV roof mounted system. System size: 56kW with 211 modules and 4 inverters(14.0kW) connecteted to 3 phase MSPNote: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
7964	15041-10000-03537	2901 S CENTRAL AVE	90011	9	117A209   108	5128021001	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.01561	-118.25643	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 7740 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7965	18041-10000-18500	854 S VERMONT AVE	90005	10	132B197   669	5077024030	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	34.05639	-118.29144	kitchen addition and canopy at the el jalapeno chicken restaurantPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7966	14041-10000-34662	758 N WILCOX AVE	90038	13	141B185   275	5533034022	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.08509	-118.33084	PC FOR POWER AND ENERGY. NEW 5 STORY 36 UNITS APARTMENT BUILDING. TOTAL AREA 32000 SQ FT. 8 UNITS OF 10 (800AMP)PANELS HAVEN'T BEEN PAID.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7967	12041-10000-25165	550 S FLOWER ST	90071	9	130-5A209 186	5151024004	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	11/02/2012 12:00:00 AM		Permit Finaled	12/11/2012 12:00:00 AM	ADDRESS	34.05028	-118.25708	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING ON THE 2ND FLOOR HOTEL FUNCTION AREA FOR PING PONG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7968	18041-20000-44288	15840 W VENTURA BLVD unit 100	91436	5	168B141   638	2283009012	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.15548	-118.47886	ti to an existing dental office.  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
7969	17041-10000-43760	5001 W WILSHIRE BLVD	90036	4	135B185   544	5507019029	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Issued	12/06/2017 12:00:00 AM	ADDRESS	34.06229	-118.33908	REMOVE OUTDOOR METAL HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7970	14041-10000-24241	2756 W JAMES M WOOD BLVD	90006	1	132B197   806	5077028011	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			09/04/2014 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	PIN	34.05563964	-118.28817176	PC FOR POWER AND ENERGY. REMODELING A 2 STORY, 12 UNITS APARTMENT BUILDING. NEW CODE 2013. UPGRADING SERVICE TO 600 AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7971	15041-10000-28730	400 S HOPE ST 8&9 Floor	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	PC at couter for enegy only, ti-24 to a commercial bldg. Work is being done in the 8th and 9th floor. Scope of work: installing new lighting fixtures and receptacles. Sqft = 1994	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7972	17041-30000-37680	5455 W 111TH ST	90045	11	087B173    10	4129036910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	33.93635	-118.37364	Plan check for energy new lighting  in parking lot E at LAX. Total area:  1,132,560 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7973	12041-10000-17923	5687 E BALTIMORE ST	90042	1	154-5A229 246	5478034020	R2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.11702	-118.19438	Plan check for PV system. Single family dwelling. 7.848 kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7974	16041-20000-07030	2220 S AVENUE OF THE STARS	90067	5	129B161    53	4329003***	R4-1L-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Expired	04/24/2018 12:00:00 AM	ADDRESS	34.05241	-118.40939	Connection of domestic water pumps to emergency power in (2) (E) highrise condominium towers.  Plan check for power.  Plan check is only for clouded portions under delta-E.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7975	18041-20000-45255	13340 W SATICOY ST	91605	2	186B157   195	2303024031	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM	04/30/2019 12:00:00 AM		Issued	04/30/2019 12:00:00 AM	ADDRESS	34.20828	-118.42362	Plan check for power and energy for change of use from Warehouse to Office/Testing Laboratory T.I. 600A distribution board . Newly connected load exceed 400A . Total area: 5039 sq ft. B#18016-20000-37278	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7976	13041-10001-32248	13918 W CALVERT ST	91401	2	177B153   596	2239017009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.18202	-118.43622	Expedited RSES plan check per applicant request.((((PV1, Install  4.50 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 18 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7977	15041-20001-42306	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	2.25.2016 - Plan check for changes to approved set. Add trash compactor panel, rearrange receptacles, revise outdoor title 24 lighting/controls, adjust load for some circuits. Changes clouded Delta 5.---PC FOR POWER AND ENERGY. TI TO AN EXISTING COMMERCIAL BUILDING (365 GROCERY STORE). SCOPE INCLUDES NEW PANELS, BRANCH CIRCUITS, TRANSFORMERS, AND LIGHTING. TOTAL AREA IS 31497 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7978	12041-10002-11224	1900 W SLAUSON AVE	90047	8	108B193  1524	6001001021	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	33.98892	-118.31175	REVISED INTERIOR LIGHTING PLAN-ADDED MORE LUMINAIRES ;LIGHTING CONTROLS REMAIN THE SAME-PLAN CHK IS FOR TITLE 24 ONLY((((((((((((((((PLAN CHECK POWER AND ENERGY FOR REMODELING OF EXISTING MCDONALD'S RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7979	13041-10000-25426	3740 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.01972	-118.29033	PLAN CHECK FOR TITLE 24 ONLY. WORK ON THE GROUND FLOOR OF AN EXISTING  BUILDING ON USC CAMPUS.CONVERT OFFICE SPACE TO MEETING ROOM.  3790 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7980	16041-30001-38144	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	34.26153	-118.50259	Expedite fees only.            Installation of new roof mounted solar PV array on existing commercial medical office.  System is connected directly to utility: feed-in-tarrif.  Total system size = 100 kWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7981	11041-10000-10933	811 W WILSHIRE BLVD	90017	9	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM	05/27/2011 12:00:00 AM		Permit Expired	06/19/2013 12:00:00 AM	ADDRESS	34.04973	-118.2584	TI TO THE CORRIDOR ON THE 20TH FLOOR OF AN EXISTING OFFICE BUILDING.  T-24, W/ EMERGENCY LIGHTING.  OTC, PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7982	17041-20002-15765	16745 W SATICOY ST	91406	6	186B133   144	2205008031	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM			PC Approved	07/27/2017 12:00:00 AM	ADDRESS	34.20857	-118.49825	7.27.2017 - Revisions to approved set of plans.  Change from dimmers to manual on/off switch, fixture cutsheets added to plans.  (((6.12.2017 - Plan check for energy only. New lighting for fermentation room (for tea). 2,242sqft.Permit pulled under master application number.========REINSTALL EXITING LIGHT FIXTURES AND ADD NEW SWITCH)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7983	16041-20001-35328	17180 W BALLINGER ST	91325	12	198B133    25	2692018011	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/08/2016 12:00:00 AM	ADDRESS	34.24346	-118.5084	EXPEDITE PER APPLICANT REQUESTPlan check for installation of pv system on SFD, roof-mounted. Interconnect with a 225A MSP. 12kW ungrounded system (6+6). (61) 255W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7984	12041-10001-21198	2015 S LONG BEACH AVE WEST	90011	9	118-5A213 143	5118025001	M1-1	East Los Angeles	Southeast Los Angeles			2270.10	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM				PLAN CHECK FOR REVISION TO APPROVED PLAN. PERMIT INCLUDES ADDITIONAL BRANCH CIRCUITS.Original Work Description: AT A UNMANNED GAS/FILLING STATION, REPLACING FUEL DISPENSERS, CANOPY LUMINAIRES, ABOVE GRADE FUEL TANK, AND NEW PANELBOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7985	15041-10001-25954	2002 W SLAUSON AVE	90047	8	105B189    20	6001001900	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	33.98891	-118.31398	EXPEDITE PER CUSTOMER REQUEST PV2 INSTALL ROOF MOUNTED SOLAR SYSTEM SIZE 26KW INTERCONNECTED WITH MAIN SERVICE PANEL. REFERENCE APP# 15041-10000-25943(((PC FOR POWER AND  ENERGY TO A NEW (2) STORY COMMERCIAL BLDG. 600 AMP SERVICE, SET OF PLANS INCLUDE FIRE, AND PV SYSTEM. FIRE AND PV SYSTEM TO BE DEFERRED  BY APPLICANT  BEFORE ISSUING PERMIT OF PLANS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7986	16041-20000-31317	6255 W SUNSET BLVD Suites 220-240	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for Title 24 only. Project site is (2) suites within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,153 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7987	14041-10000-00467	6527 N COLBATH AVE	91401	2	180B153   709	2238019006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.18937	-118.43684	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 4.5 KW.(21) ENPHASE M215 MICROINVERTER(21) SOLARWORLD SW250 POLY MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7988	14041-10000-13422	301 N ROSSMORE AVE SERVICE-AREA	90004	4	138B185   106	5523004013	A1-1XL-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.07619	-118.32731	NEW 17 DEVICE FIRE ALARM SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7989	17041-20000-08011	14001 W OSBORNE ST	91331	6	195B153   210	2642031021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.23346	-118.43824	Plan check for power only. New 800A service for existing commercial building. Refeed existing panels from new service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7990	13041-20001-06197	13219 W CUMPSTON ST	91401	4	174B157   908	2345002013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.16992	-118.42021	"Modification to previously approved plans to change conduit from 3/4"" to 1/2"".  <<<<New Ephase (Microinverter)  Photovoltaic System for an existing single family dwelling.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7991	12041-10000-29863	835 W STATLER ST	90731	15	024B197    74	7442003021	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	33.76394	-118.29742	PV1.  New 10.29 KW roof mounted PV system for a single family residence.  Installing 42 modules, 1 combiner box, 2 inverters, 1 125 amp load center, and upgrading service to 225.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7992	18041-20001-16255	1520 W JAMES M. WOOD BLVD	90015	1	130-5A205 328	5137004029	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.05009	-118.27201	08-16-2018 Changes to an approved set of plan. Changes include Fused Disconnect to be rated at 22KAIC minimal. All changes has been clouded as delta 3. Plan check only. Permit shall covered under Master Permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7993	18041-10000-17516	205 S OCEAN FRONT WALK	90291	11	109-5A141  69	4286030002	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	33.99515	-118.4808	FULL PLAN CHECK FOR A NEW RESTAURANT. (POWER & ENERGY)NEW SERVICE, PANELS & CIRCUITS. 5,000 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7994	16041-10000-11702	10777 W WILSHIRE BLVD	90024	5	132B153   173	4360004012	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Expired	05/21/2018 12:00:00 AM	ADDRESS	34.06038	-118.43901	PC FOR POWER ONLY. SCOPE INCLUDES TEMPORARY POWER FOR A CONSTRUCTION SITE; 800A 277/480V 3 PHASE 4 WIRE SERVICE. ALSO ADDING TWO 75KVA TRANSFORMERS, AND TWO 200A SUB-PANELS. CONSTRUCTION SITE IS FOR A NEW 6 STORY 56-UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
7995	17041-20000-33388	4906 W SANTA MONICA BLVD	90029	13	144B197   766	5538012011	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.0906	-118.29646	Retail tenant space improvements.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7996	17041-20000-16268	20244 W SEPTO ST	91311	12	201B113   109	2741017012	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.25077	-118.57486	pv1install roof mounted pv system sized 7.6kw iterconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
7997	15041-10000-35011	3015 S HOOVER ST	90007	9	121-5A201 147	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.02712	-118.28423	Installation of (N) 52-device fire alarm system in a new single story commercial building on USC's campus.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7998	12041-20000-25864	10990 W WILSHIRE BLVD 400	90024	5	132B149   138	4324002***	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.0577	-118.44711	"T.I. to an existing offices space.  Sute 400.  Load is less than 400amps per applicant.  PLAN CHECK ONLY for Energy with Emergency lighting.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
7999	17041-20000-45747	601 S FIGUEROA ST 31st, 32nd-33rd flrs	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for power and energy. TI to 31st, 32nd, and 33rd floor offices in high rise building. >400A of new load. New lighting (incl. emergency) - 50,500sqft. Building permit not yet submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8000	13041-20000-03769	20051 W VENTURA BLVD # D	91367	3	174B113   439	2166001031	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	PIN	34.1716613	-118.57023176	Installing light fixtures to existing circuits in space D.  Plan checked for T24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8001	19041-20000-15666	24430 W HATTERAS ST	91367	3	174B089   382	2046009011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.17291	-118.65698	PV1.  Install 17.16 kW DC / 14.58 kW AC-CEC roof mounted grid tied PV system.  (52) modules with (2) 7.6 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8002	11041-10000-04335	2500 E 223RD ST	90810	15	045B217     6	7315010801	M3-1	Harbor	Port of Los Angeles			2941.20	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	33.82401	-118.22493	TI IN AN EXISTING COMMERCIAL/INDUSTRIAL BUILDING. TI IN THE EXISTING RESROOMS AND ADDING TRAINING ROOM & BREAK ROOM.  EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8003	18041-20000-20448	4620 N TOBIAS AVE	91403	4	168A151   112	2265007008	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.15534	-118.45184	Plan check for PV roof mounted system, system size: 15.2kWac with 40 modules and 2 inverters (7.6kW) Main Service 400A.Fees $68.68 due California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8004	14041-10000-04020	1147 S HOPE ST	90015	14	126A207    20	5138014003	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM			Reviewed by Supervisor	02/24/2014 12:00:00 AM	ADDRESS	34.04129	-118.2642	600AMP SERVICE UPGRADE FOR CHANGE OF USE TO GYM. ALL LOADS ARE NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8005	16041-20002-31717	3850 S CRENSHAW BLVD	90008	10	117B185   775	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.01602	-118.33474	"01/11/2018 Changes to an approved set of plans. Changes have been made to the power and lighting floor plans. All changes have been reflected onto the Title 24 forms.*****Previous Work Description*****TI TO AN EXISTING BUILDING.  REPLACEMENT OF EXISTING PANELS ONE FOR ONE.  ADDITION OF NEW PANEL ""AC"" NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 9905"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8006	18041-20000-29928	24203 S ROSCOE BLVD	91304	12	192B089   184	2017038016	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.21965	-118.65411	pv1install roof mounted pv sysem sized 3KW aC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8007	15041-10000-04918	10030 N REMMET AVE	91311	12	204B105   822	2747010***	ZI-1022, ZI-1117 MTA PROJECT, ZI-1732 COUNCIL OFFICE NOTIFICATION (ROCK OUT-CROP	North Valley	CHATSWORTH - PORTER RANCH	CHATSWORTH		1132.13	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.25277	-118.60034	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3576 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8008	14041-10000-25952	420 S SAN PEDRO ST	90013	14	127-5A213 633	5147005202	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.04498	-118.24321	TENANT IMPROVEMENT IN OFFICE SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8009	15041-10000-01564	970 N BROADWAY	90012	1	136-5A215 176	5414015008	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	PIN	34.06657024	-118.23561805	Energy plan check for restaurant T.I  in a 2-story building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8010	17041-10000-27923	11845 W OLYMPIC BLVD 8TH FLR	90064	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.03291	-118.45177	8TH FLOOR REMODEL FOR CORRIDORS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8011	19041-20000-09244	20511 W DUMONT ST	91364	3	169-5A111  15	2166020001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Issued	03/14/2019 12:00:00 AM	ADDRESS	34.16063	-118.58076	Plan check for PV roof mounted system, system size: 11.025KW with 35 PV Modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8012	14041-10001-08616	25965 S NORMANDIE AVE LEVEL 3	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	((5/1/2014- REVISIONS MADE TO APPROVED SET. ADDED NEW ROOM, NOT A PATIENT CARE AREA. PLAN CHECK FOR ENERGY ONLY)))T24 FOR EXISTING MEDICAL BUILDING. RETROFITTING LIGHTS ONLY. CONVERTING FLOURESCENT FIXTURES TO LED FIXTURES. RETROFIT KIT IS UL LISTED FOR THE APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8013	08041-10003-27353	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM			PC Approved	07/23/2010 12:00:00 AM	PIN	33.93847109	-118.41935625	Changes to the approved plans. Provide 60Amp protection for the receptacle for the portable generator and modify the ground.  Maximum of 3 @ 40 HP motor, can operate under normal power and only 1 @ 40HP motor can operate under emergency power. (((((Changes to approved plans.  Revise the location of the service equipment and add circuits/equipment. LAWA - New Pumpsation, street lighting, and signals at LAX (3/3).  Permit is for new ckts, new panels, new equipment.  P/C is for Power only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8014	16041-20000-24357	11250 N ZELZAH AVE	91344	12	210B129    90	2711018002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.27527	-118.52319	PV1.  Installation of 8.59 kW AC roof mounted PV system.  (35) modules with 10 kW rated inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8015	19041-20000-09538	9147 W LEANDER PL	90210	4	153B165   364	4388018019	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Expired	11/08/2023 12:00:00 AM	PIN	34.11389359	-118.3954287	INSTALLATION OF TWO 5KW TESLA POWERWALL ESS TO EXISTING SFD WITH EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8016	14041-10000-32468	2160 N LAKE SHORE AVE	90039	13	145-5A211 287	5420008002	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.0924	-118.25255	Installation of new roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8017	18041-10000-08747	1888 CENTURY PARK EAST 1108 &-1110	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	PIN	34.06160176	-118.41389445	PC FOR POWER ONLY, TENANT IMPROVMENT TO THE (E) OFFICE SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. 2385	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8018	13041-20000-20600	5927 N LEMONA AVE	91411	4	177B145   511	2243021010	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.17835	-118.45983	Plan check for energy only. ADD STORAGE BLDG / WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8019	19041-20000-42412	4926 N ENCINO AVE	91316	5	168B129   105	2290004026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.16013	-118.51402	Installation of 27 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8020	15041-10000-24699	8516 S FIGUEROA ST Suite A	90003	8	097-5A201 214	6032035033	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	33.96063	-118.28251	TI TO AN EXISITNG SINGLE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1441.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8021	16041-20000-27458	4900 N SERRANIA AVE Murphy	91364	3	169-5A109  71	2166046026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.15898	-118.58816	"Plan check for power only. Project site is an existing commercial building. Project scope is the replace of electrical distribution equipment for Murphy Building (""MSA""). No new load is being added onto subpanels."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8022	11041-10000-25746	8484 N SAN FERNANDO ROAD Rear Bldg	91352	6	192B173   223	2632027023	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.22408	-118.37533	INSTALL ADDITIONAL DEVICES ON AN EXISTING FIRE ALARM SYSTEM IN THE REAR BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8023	16041-20001-32089	6345 N VARIEL AVE	91367	3	180B105    66	2149001032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM			Verifications in Progress	11/02/2016 12:00:00 AM	ADDRESS	34.18643	-118.5936	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8024	13041-10000-13369	380 WORLD WAY 4th Floor	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLAN CHECK FOR POWER AND ENERGY. FIRST TIME TENANT OF TSA OFFICE ON THE 4TH FLOOR OF TOM BRADLEY INTERNATIONAL AIRPORT.  EXISTING CORE AND SHELL.***ADDITIONAL FEES ON SUBMITTAL 2Fees are paidVariance was filed for the 30 day reading--NM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8025	14041-20001-29405	4365 N MAMMOTH AVE 1-24	91423	4	165B153   378	2271017027	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			11/12/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.15002	-118.43269	EXPEDITE FEESSUBMIT FOR NEW PERMIT. THIS SYSTEM IS A 20KW SYSTEM WITH 2 INVERTERS. 84 MODULES. SYSTEM IS A LOAD SIDE CONNECTION. ROOF MOUNTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8026	15041-20001-43683	9943 N ARLETA AVE	91331	6	201B153   130	2645016001	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.25073	-118.43555	01-28-2016 Change to approved set of plans. Changes include inverter SMA SB2500HF-US-22 to SMA SB3000HF-US-22{{{{{{PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.12KWdc/2.5KWdc. (12)MODULES-CANADIAN SOLAR CS6P(1)INVERTER-SMA SB2500HF-US-22}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8027	14041-20000-29589	11877 N STONE GATE WAY	91326	12	217-5A115 117	2701025005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.28955	-118.56775	PV1Using standard plan.Install roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 6kW. Ungrounded system.32 255W pv modules across 4 strings (8+8+8+8). Combing strings to (16+16).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8028	18041-20001-14845	734 E 3RD ST	90013	14	127-5A215  12	5163012004	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.04556	-118.23683	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET CLOUDED CHANGES ONLY. CHANGE TO SERVICE EQUIPMENT LAYOUT AND ADDITION OF A SUMP PUMP. MINOR CHANGES MADE TO SINGLE LINE, LOAD CALC, AND FLOOR PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8029	10041-10000-24047	1152 S ELM DR	90035	5	132A167   197	4330032016	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM			PC Approved	12/02/2010 12:00:00 AM	ADDRESS	34.05554	-118.39476	"TI IN AN EXISTING RETAIL STORE.  PLAN CHECK IS FOR T-24 ENERGY CALCS.  ""COMPLY WITH DEPARTMENT ORDER effective date 09/30/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8030	14041-20001-28307	7653 N TEXHOMA AVE	91325	12	186B129    66	2202002019	RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM			PC Approved	11/04/2014 12:00:00 AM	ADDRESS	34.21006	-118.51549	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 21.8KW INTERCONNECTED WIH MSP.(70) SUNPOWER 327W MODULES(4) POWER ONE INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8031	13041-20000-30947	12910 W CULVER BLVD	90066	11	105B157   578	4221031006	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	33.98314	-118.42695	PC FOR T24 ENERGY ONLY. TOTAL AREA 4698 SQ FT. RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8032	19041-20000-06390	4115 N ALONZO AVE	91316	5	165B129   297	2184032039	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Issued	02/21/2019 12:00:00 AM	ADDRESS	34.14561	-118.52452	PLAN CHECK FOR NEW 11.4KW AC ROOFTOP PV SYSTEM ON EXISTING SFD. SCOPE OF WORK INCLUDES (50) HANWHA Q PEAK PV MODULES WITH INDIVIDUAL P320 OPTIMIZERS, AND (1) SE11400H INVERTER	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8033	16041-20000-15707	14334 W RUNNYMEDE ST	91405	2	186B149   503	2215024007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Expired	06/15/2018 12:00:00 AM	ADDRESS	34.20562	-118.44572	$0 permit fee is due to State Senate Bill SB 1222Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (49) modules, and (1) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8034	18041-20002-22619	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Issued	08/07/2018 12:00:00 AM	ADDRESS	34.1937	-118.49152	8/7/2018Changes to an approved set of plans.  changes to reduce module count add optimizers and downsize inverter rating.  Total system size 99.9KW AC, 75KW AC CEC rating.  (255) canadian solar CS1K-325(128) solaredge optimizers P800(3) solaredge SWE33.3KUS inverters((((Plan check for PV2 roof mounted on commercial building, system size; 75kW with 265 modules and 3 inverters(30kW) connected to  800A  Service.Fee $ 0.00 due to California Senate Bill 1222))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8035	11041-10000-02729	1012 N SWARTHMORE AVE	90272	11	129B125   838	4423016024	C2-1VL, R3P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	05/20/2011 12:00:00 AM	ADDRESS	34.0477	-118.5253	TI IN AN EXISTING BANK. PLAN CHECK IS FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8036	18041-20001-45700	16303 W BIRCHER ST pv1	91344	12	213B137   353	2605018016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.28135	-118.48682	11/30/2018changes to an approved set of plans.  changes to downsize inverter to 10KW AC.  this is plan check only.((((pv1install roof mounted pv system sized 4.1KW AC interconnected with msp.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8037	18041-20000-09554	22433 W NORTH SUMMIT RIDGE CIR	91311	12	198B101    60	2727022007	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2018 12:00:00 AM	04/02/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.24218	-118.61597	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20.79 KW$0 PERMIT FEE PER STATE SENATE BILL SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8038	16041-10003-28519	10161 N WHITE OAK AVE	91325	12	204B129   262	2734004022	RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM			PC Approved	09/28/2016 12:00:00 AM	ADDRESS	34.25577	-118.52003	Changes to approved set  includes additional AC  disconnect and meter.********************************************************************************* Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 12 kWac.  Two SMA SB6000TL inverters with 37 modules total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8039	16041-20000-23427	9131 N OAKDALE AVE #100	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.23697	-118.56716	Plan check Title 24 only T.I. in existing office. Total area: 3,191 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8040	14041-20000-11029	2800 N BEACHWOOD DR	90068	4	156A189   172	5583013015	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.1214	-118.32171	Roof mounted PV system with microinverters.  System size 4.32KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8041	15041-10000-18004	620 E 111TH PL	90059	8	087A207    36	6071022011	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	33.93386	-118.26445	TI TO AN EXISTING COMMERCIAL BUILDING.  RETROFIT EXISTING FIXTURES.  PLAN CHECK FOE ENERGY.  TOTAL SQUARE FOOTAGE 64175	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8042	17041-10000-16063	10250 W SANTA MONICA BLVD #1460	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for power and Title 24.  First time build out of tenant retail space (Peleton).  Two new subpanels with 30 kVA transformer feeding new lighting and receptacles.  Total area = 1,110 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8043	15041-20000-23008	7511 N SAN FERNANDO ROAD	91505	2	186B181   281	2466035002	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM			Reviewed by Supervisor	08/13/2015 12:00:00 AM	ADDRESS	34.20756	-118.35235	Plan check for power only.  New 1,200 A service connected to a new 1,200 A distribution panel (which will be under seperate permit).  This panel supplies a new 300 kVA transformer feeding existing 800 panel.  New meters on each distribution panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8044	14041-10000-29134	7307 N FIGUEROA ST 103-104	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	ADDRESS	34.13662	-118.18837	TI: interior remodel from core and shell tenant space to restaurant.  Plan check for power only.  Energy plan check and electrical permit already under 14041-10000-03443.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8045	17041-20000-40458	605 W 7TH ST	90017	14	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.04758	-118.25677	Change of use from retail to restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8046	18041-10001-19611	3201 S HOOVER ST STE 1824	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	34.0255	-118.28448	TITLE 24 MODIIFICATION - CHECK FOR MODIFICATION OF CONTROLS SYSTEM ONLY UNDER DELTA 1 Energy plan check for a change of use T.I. located in the ground level. Scope includes new lighting and equipment. Total area is 1205-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8047	15041-10000-18367	8000 W SUNSET BLVD #B135	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.09783	-118.36466	PLAN CHECK FOR POWER AND ENERGY FOR NEW ATT STORE FIRST TIME TENANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8048	17041-20002-39882	10727 W WILSHIRE BLVD 1-109	90024	5	132B153   123	4360033***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Approved	05/15/2018 12:00:00 AM	ADDRESS	34.06081	-118.43692	05-15-2018, Changes to an approved set of plans, changes include conduit from rigid galvanized to PVC. PVC Shall be listed according to it's use and type of construction. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8049	16041-10001-44957	9325-9329 W PICO BLVD	90035	5	132A167   206	4330035014	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			Re-Activate Permit	04/29/2020 12:00:00 AM	ADDRESS	34.05542	-118.39361	FEE EXPEDITEPC FOR PV2 COMMERCIAL ROOFTOP SOLAR. SYSTEM SIZE IS 20KA AC USING CENTRAL INVERTER SYSTEM WITH TOTAL OF 57 MODULES AND POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8050	18041-20000-34143	11444 W ALBATA ST	90049	11	135B145   719	4365017008	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.06314	-118.4621	PV1.  Install 11.025 kW DC roof mounted grid tied PV system.  (35) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8051	14041-10001-08643	10673 SATICOY ST	0	2									Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			Reviewed by Supervisor	05/16/2014 12:00:00 AM				EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(19) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8052	11041-20000-11571	5555 W MELROSE AVE Post-Production	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.08363	-118.32191	Revision to the approved plan. New Construction of 3 story building.  Third floor has already been completed under a seperate application number.  This is for tenant buildout of the first and second floor.  Tenant is the same for the first and second floor.  Applicant is submitting marked up set for as  reference for as built plans submitted.  Reference plan check number 09041-20000-05233 for the Post Production building.  Plan check is for as built and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8053	16041-20000-38888	10730 N MEMORY PARK AVE	91345	7	207B145   239	2649003028	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Apartment			11/02/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.26537	-118.46322	Plan check for installation of solar pv system, roof-mounted on apartment. Interconnect with 400A MSP (200A split bus). 13.6kW ungrounded system. (50) 335W pv modules. Each module has a 400W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8054	18041-20000-37367	15455 W SAN FERNANDO MISSION BLVD SUITE #301	91345	7	210B145   128	2664007024	(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Issued	11/28/2018 12:00:00 AM	ADDRESS	34.27207	-118.46923	Plan check for Title 24 only. Project site is the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,394 sq. ft.Note: Building application has been generated under 18016-20000-29102	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8055	19041-10000-39256	2655 N RUTHERFORD DR	90068	4	153A191    41	5580006031	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.11544	-118.31971	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.78KVA PV1 SYSTEM CONNECED TO EXISTING 11.4KVA PV SYSTEM CONSISTING OF 12 MODULES WITH MICROINVERTERS(IQ7X) AND 2 TESLA POWERWALLS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8056	13041-20000-35920	10660 W COHASSET ST	91352	2	186B177   299	2410011040	RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.20653	-118.36323	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8057	10041-20000-24282	14401 W VENTURA BLVD	91423	5	166-5A151 296	2265014017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.15069	-118.44613	PLAN CHECK T24 ENERGY FOR TI AT CAR DEALERSHIP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8058	15041-10000-40513	11440 W VENTURA BLVD SUITE 101	91604	2	162B169   680	2378022023	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.13941	-118.38026	MASSAGE PARLOR TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8059	12041-10001-19058	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	T24 PC FOR EN. CHANGES TO LTG IN BATH/KITCH/ENTRYChange to lighting, receptacles, load for an existing restaurant.  Load is 132.7 Amps and Occupancy load is 56, per applicant.  PLAN CHECK ONLY for Energy,  with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8060	17041-10000-23445	3096 S MCCLINTOCK AVE UNIT 14B-BLDG 4	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM			PC Info Complete	07/20/2017 12:00:00 AM	ADDRESS	34.02647	-118.28575	RESTAURANT TI. PC FOR T24 ENERGY ONLY.Total affected area 2373 sq.ft. Scope includes new panels lights and receptacales. Including new equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8061	13041-10001-29491	8612 N CALVIN AVE	91324	12	195B117   399	2783021013	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.22678	-118.55563	Expedited plan check per applicant request.((((PV1, Installing roof-mounted solar array, interconnect with main panel. System size: 6.75.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8062	16041-20000-03742	16860 W CHATSWORTH ST	91344	12	207B133   524	2684001036	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.26456	-118.49978	Plan check for Title 24 only outdoor lighting. Total area: 3300 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8063	16041-10003-09208	3500 W WILSHIRE BLVD	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/17/2017 12:00:00 AM	ADDRESS	34.06157	-118.30077	11/14/17 PC FOR REVISIONS TO APPROVED SET TO REFLECT FIELD INSTALLATION.  CHANGES MARKED UNDER DELTA 13. SCOPE INCLUDES OF SIGN AND EXTERIOR LIGHTS WITH REVISION TO PANEL SCHEDULE AND TITLE 24 FORMS ALL PERMIT FEES PAID UNDER ORIGINAL PERMIT. THIS IS PLAN CHECK ONLY!THESE CHANGES,  TOGTHER WITH DELTA 12 (10002) WAS TO BREAK THE ORIGINAL WORK (UNDER ORIGINAL) TO EXTERIOR AND SIGN LIGHTS TO 2 PHASES DUE TO FINANCIAL HARDSHIP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8064	14041-20000-17604	5200 N LANKERSHIM BLVD 7th floor	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.16511	-118.37448	TI to 7th floor tenant space in (E) commercial office highrise building.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8065	13041-10000-32647	327 E HARRY BRIDGES BLVD	90744	15	027B209   187	7418029027	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Expired	12/17/2015 12:00:00 AM	ADDRESS	33.77164	-118.25825	T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 3580 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8066	17041-10000-32105	141 W 47TH ST	90037	9	112-5A203 302	5110007015	R2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.00116	-118.2754	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.80KWac. (16)MODULES-AXITEC AXIpower AC-265P(16)OPTIMIZERS-P320(1) INVERTER-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8067	11041-10000-09926	1735 N VINE ST	90028	13	148-5A187  55	5546004403	C4-2D-SN	Central	Hollywood	Hollywood United		1902.00, 1910.00	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	06/03/2011 12:00:00 AM	ADDRESS	34.10272	-118.32695	Central Station monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8068	17041-20000-20150	3501 S TROUSDALE PKWY 1st,2nd fl-corridor	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.02194	-118.28455	Plan check for energy only. TI to main entry lobby and corridors on 1st and 2nd floor of classroom building (USC). New lighting (incl. emergency) - 4,237sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8069	14041-20000-21908	15046 W GAULT ST	91405	6	183B145   209	2220006057	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.19925	-118.46143	(($0 permit fee due to senate bill 1222 from 2012))PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 12kW.(2) SolarEdge SE6000A-US transformerless inverters(52) Solar World SundModule SW280 Poly pv modules(52) SolarEdge P300 power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8070	15041-10000-06855	10250 W SANTA MONICA BLVD #1045	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	PIN	34.0586034	-118.41904766	new microsoft store at the century city mallPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8071	19041-20000-18305	3651 S TROUSDALE PKWY Suites-252 & 352	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.01922	-118.28617	Plan check for Title 24 only. Project site is classrooms within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,642 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8072	10041-10000-06188	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	07/07/2010 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.14246	-118.2705	RELOCATE EXISTING DUCTBANKS TO MAKE ROOM FOR FUTURE BUILDINGDS. INSTALL A TOTAL OF 12 NEW DUCTBANKS WITH DIFFERENT VOLTAGE AND CURRENT RATINGS (UPTO 34.5KV) WITH A TOTAL OF 1900 FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8073	11041-10001-20628	1110-1114 E LAKE ST BLDG 24	90291	11	111B145   161	4243001039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Closed	08/12/2014 12:00:00 AM	ADDRESS	34.00316	-118.45956	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8074	19041-20000-32066	20808 W ACORN CIR UNIT #236	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.29426	-118.58695	PV1.  Install 3.15 kW roof mounted PV system.  (9) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8075	16041-10000-05823	4910 N VAN NUYS BLVD	91403	4	169-5A151  69	2248007140	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.15985	-118.4485	PC FOR A NEW FIRE ALARM SYSTEM TO A 3 STORY MEDICAL BUILDING. FIRE ALARM SYSTEM IS FOR THE CORE AND SHELL OF THE BUILDING. SCOPE INCLUDES 19 NEW FA DEVICES, 1 FA PANEL, AND 1 FA COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8076	15041-20001-26831	5647 N LUBAO AVE	91367	3	174B113   275	2153002016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM			PC Approved	11/19/2015 12:00:00 AM	ADDRESS	34.17356	-118.5675	PV1 SFD. TOTAL SYSTEM SIZE 11.4KW AC USING SINGLE INVERTER SYSTEM. USING 60 MODULES IN TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8077	19041-20000-47717	13263 N WHEELER AVE UNIT 7	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8078	13041-10000-23013	707 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			08/23/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	33.78001	-118.24199	PLAN CHECK FOR A METHANE MITIGATION SYSTEM IN THE PORT OF LOS ANGELES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8079	16041-10008-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	PIN	34.2363795	-118.55851216	[[[11/26/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. MINOR CHANGES TO SHOW FUTURE FAN COIL UNITS, HEAT PUMPS AND RTUS]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8080	16041-10000-08576	8631 W 3RD ST #930E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.07373	-118.38036	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING  COMMERCIAL BUILDING (CEDAR-SINAI MEDICAL CENTER). SCOPE INCLUDES REPLACING RECEPTACLES AND ADDING TWO LIGHTING FIXTURES IN THE OFFICE/CONFERENCE SPACES. TOTAL AFFECTED AREA IS 147 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8081	18041-10000-16851	2825 S SAN PEDRO ST	90011	9	118-5A207 157	5128013027	CM-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.01935	-118.26294	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8082	16041-10000-13093	888 S OLIVE ST	90014	14	127-5A209 127	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Issued	04/14/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	PC FOR AN ADDITION TO AN EXISTING FIRE ALARM SYSTEM. SCOPE INCLUDES AN ADDITION OF 10 NEW FIRE ALARM DEVICES FOR A TI. THE NEW DEVICES IS FOR A NEW COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8083	11041-10000-25781	7150 N TAMPA AVE	91335	3	183B117    99	2129001009	R1-1, RD2-1	South Valley	Reseda - West Van Nuys	Reseda		1325.00	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.20068	-118.55332	T.I. to an existing senior care center.  Changing lights, moving walls and adding circuits 73 new circuits.  Full plan check requested by applicant.  Work is to first floor of tenants 3-story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8084	13041-20000-30290	4445 N MORELLA AVE	91607	2	165B169   130	2364011012	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.15149	-118.39008	"PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10KWAC. 30 MODULES AND 2 INVERTERS AND 1 PV SUBPANEL.  "" low permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8085	10041-10000-14472	6740 W HOLLYWOOD BLVD	90028	13	148-5A185 149	5547012016	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Public Safety Only			07/27/2010 12:00:00 AM			Corrections Issued	08/09/2010 12:00:00 AM	ADDRESS	34.10139	-118.33752	NEW FIRE ALARM SYSYTEM.  ELECTRICAL PLANS WERE SUBMITTED UNDER PCIS # 10041-10000-14469.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8086	17041-20000-20641	20801 W RINALDI ST	91311	12	210B109   548	2706007024	(T)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.01	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.27025	-118.58647	New parking lot. Equipment rated over 600 A.  (8) new EV chargers.  Plan check for energy.  37,805 sq ft hardscape.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8087	14041-10000-06635	12836 W ARROYO ST	91342	7	219B161   285	2525017008	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.2944	-118.412	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 21636 SQFT. ALL WORK TO BE INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8088	19041-10000-47840	1114 N ISABEL ST	90065	1	147A219   330	5454023010	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.09597	-118.22326	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 17  (PANASONIC 330W) MODULES, 17  (ENPHASE IQ7X) MICROINVERTERS,  2 TELSA POWERWALL'S, CONNECTED TO AN EXISTING 100A MAIN SERVICE PANEL. SYSTEM SIZE IS 5.61KW DC & 5.35KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8089	17041-10000-37851	1129 N MONUMENT ST	90272	11	129B125   390	4423001039	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.0497	-118.52498	*Zero permit fee per Senate Bill 1222*PV1, NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH TWO 5.8KVA/13.5KWH POWERWALL STORAGE BATTERIES. TOTAL SYSTEM SIZE IS12.025KWdc / 10.00KWac.(37)MODULES-SOLARCITY STANDARD #SC325(37)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE10000A-US-ZB-U(2)AC POWERWALL 5.8KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8090	19041-20002-00983	7432 N RESEDA BLVD	91335	3	186B125   557	2119017054	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.20567	-118.53585	4/23/2019changes to an approved set of plans.  changes to reconfigure strings and meet site conditions.  this is plan check only.((((permit fee $0.00 by senate bill no.1222Plan check for a PV2 roof-mounted PV system. System size is 128.7 kWdc/112.4 kWac and consists of (4) inverters, (390) modules, and (1) load center.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8091	13041-10000-18721	4953 N DEL MORENO DR	91364	3	168B113    28	2166044011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM			Ready to Issue	07/16/2013 12:00:00 AM	ADDRESS	34.16053	-118.5763	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN. SYSTEM SIZE IS 7.350 KW DC. PERMIT PULLED UNDER APPLICATION NUMBER 13041-20000-17814. 30 MODULES IN 3 STRINGS [INVERTER: FRONIUS # IG PLUS V 7.5 |||| MODULES: TRINA SOLAR # TSM-245PC05/PA05.18]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8092	11041-20001-08633	189 S THE GROVE DR Ste# H80	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	Revision to the approved plan. Change T24, panel schedule & load calc. EPC is for delta 2 & 3.  (((((((((((((PER CUSTOMER REQUEST, FULL PLAN CHECK.  EXISTING GAP STORE BE DIVIDED TO ACCOMODATE ANOTHER TENANT IN EXISTING RETAIL SPACE.  CUSTOMER WOULD LIKE THIS PLAN CHECK TO BE ACCOMPANIED BY PCIS# 11041-10000-08624.  PLAN CHECK IS FOR POWER AND ENERGY.))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8093	17041-20001-24365	13310 N DE FOE AVE	91342	7	225B145   455	2501022064	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	34.31322	-118.46088	expeditepv1install roof mounted pv system sized 10.3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8094	17041-20000-01505	6815 N NOBLE AVE SUITE 105	91405	6	183B145   721	2220020023	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Issued	01/17/2017 12:00:00 AM	ADDRESS	34.19434	-118.46198	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EXISITNG MEDICAL OFFICE. WORK NOT IN PATIENT CARE AREA. SUITE 105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8095	13041-10001-26290	11151 N BERTRAND AVE	91344	12	210B125   232	2715020037	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South	YES	1112.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.2736	-118.52563	][][]EXPEDITED PER APPLICANT REQUEST[][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200A MAIN IN A 1-STORY HOUSE. WORK DONE ON A CENTRAL INVERTER-STANDARD PLAN, WITH COMBINER BOX. SYSTEM SIZE IS 11KW DC WITH (44) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG PLUS V 10	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8096	18041-10000-03706	555 W 5TH ST #3100	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 4364 SQ. FT.  B#17016-20000-35451	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8097	13041-20000-32261	11777 W SAN VICENTE BLVD	90049	11	129B145    59	4401017026	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.05331	-118.46832	PC FOR T24 ENERGY ONLY. RELOCATION OF LIGHTING IN EXISTING OFFICES. NEW LIGHTING. TOTAL AREA 4863 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8098	18041-10000-42270	11100 W SANTA MONICA BLVD 525	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI FOR AN INTERIOR OFFICE SPACE, SUITE 525. SCOPE INCLUDES NEW LIGHTS AND RECEPTICALS. TOTAL AFFECTED AREA IS  1261 SQ. FT. T-24 ONLYB#: 18016-10000-35217	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8099	18041-10001-13043	18607 W HILLSBORO ROAD	91326	12	207B121   803	2728030001	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.26038	-118.54053	INSTALL NEW ROOF SOLAR PANNEL, 35 PANELS TOTAL ON TOP OF EXISTING SFD ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8100	15041-20001-40911	4919 N BLUEBELL AVE	91607	4	168B161   169	2357020004	R1-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	34.15993	-118.41174	expedite per applicantPV1, roof mounted solar panel 11.4kW AC system interconnect with (N)225A service.(35) modules: LG315N1C-G4(1) inverter: SE11400a-usPower optimizer is used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8101	15041-20001-13035	413 W 101ST ST	90003	8	091-5A201 153	6054033017	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM			PC Approved	05/11/2015 12:00:00 AM	ADDRESS	33.94474	-118.28103	Expedite per applicant request. (((((((Plan check for PV roof mounted 7.14kW micro-inverter connected to existing 200A service with 28 modules and 1 load center.)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8102	17041-20000-42700	525 N WILTON PL 1-88	90004	4	141B189   806	5522015025	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			11/28/2017 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	02/09/2021 12:00:00 AM	ADDRESS	34.08101	-118.31378	PLANCHECK FOR POWER AND ENERGY. NEW 5-STORY ,88-UNIT APARTMENT.BUILDING PERMIT:  16010-10000-04960FIRE ALARM VARIANCE HAS BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8103	14041-20001-05382	23440 W COMMUNITY ST	91304	12	192B093   305	2005016025	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.22104	-118.63783	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING SOLAR EDGE SYSTEM WITH POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8104	14041-20001-11791	14528 W SAN JOSE ST	91345	7	207B149   788	2648021013	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.26132	-118.44946	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 5.25kW(1) SolarEdge #SE3800A-US-ZB-U transformerless inverter(21) Canadian Solar #CS6P-250PX pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8105	17041-10000-43271	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	33.94221	-118.40701	Plan check for Title 24 only in existing space T.I. Starbucks lighting and receptacles. Total area: 700 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8106	17041-20002-44042	23115 W SHERMAN PL	91307	12	183B097    55	2021014044	CR-1VL, P-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM			PC Approved	10/25/2018 12:00:00 AM	ADDRESS	34.20115	-118.63061	10/25/2018 Changes to an approved set of plans. Changes have been made to the lighting floor plan and the the emergency egress lighting. Photometric analysis has been updated.10/09/2018 Changes to an approved set of plans.  changes noted delta 1 only.  changes to reflect fiels conditions.  this is plan check only.  ((((ti to an existing medical clinic, first time tenant.  plan check for power and energy.  NON-OSHPD-3BUILDING APPLICATION NUMBER 17016-20000-35070))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8107	12041-20000-27488	9012 W CRESCENT DR	90046	5	150B169   632	5563020027	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.10868	-118.38706	Photovoltaic system on roof of a single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8108	18041-20001-16090	5916 N FIGUEROA ST	90042	1	151-5A229 114	5492015028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.1106	-118.19037	07/19/2018 Changes to an approved set of plans. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Plan check for Title 24 only in existing space T.I. new lighting receptacles for existing service. Total area: 936 sq ft. B#18016-10000-08778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8109	19041-10000-02538	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	PC FOR FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES FIRE PANEL UPGRADE WITH NEW DEVICES IN A WAREHOUSE/ RETAIL SPACE. (1) NEW FIRE ALARM AND (352) FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8110	17041-20002-14009	22630 W MACFARLANE DR	91364	3	171B097   833	2075022003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.16281	-118.61935	7/18/17changes to an approved set of plans.  changes include (41) trina solar modules TSM-300DD05A. this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8111	14041-10000-17439	739 S OGDEN DR 1-45	90036	4	132B177    82	5086010018	R3-1	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Public Safety Only			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.06151	-118.36021	new fire warning system for 4-storiesapartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8112	19041-10000-46444	3705 N GLENRIDGE DR	91423	4	162B153   565	2272032019	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM			No Progress	11/21/2019 12:00:00 AM	ADDRESS	34.13762	-118.43271	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 24  (HANWHA-Q PEAK DUO BLK-G5/SC315) MODULES,  1 (SOLIVIA 7.6TL) CENTRAL INVERTER, 1 TELSA POWERWALL, CONNECTED TO AN EXISITING 100A MAIN SERVICE PANEL. SYSTEM SIZE IS 7.56KW DC & 7.60KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8113	14041-20000-00739	12064 N WOOD RANCH ROAD	91344	12	216B129    85	2601068006	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.29055	-118.52513	PV1 TRANSFORMERLESS SYSTEM. SOLAR OPTIMIZER USED. TOTAL SYSTEM SIZE 6.0 KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8114	19041-20000-42614	22164 W ECCLES ST	91304	12	192B101   427	2010019020	RS-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.22247	-118.61041	Plan check for PV roof mounted system, PV system size: 3.1KW DC with 3.8KW AC with 10 PV Modules and 1 inverter(3.8KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8115	17041-10000-02324	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.13829	-118.34154	FULL PLAN CHECK REMODEL POOL BATH NORTH BLDG. 4 OF 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8116	16041-20001-41140	360 S MAPLETON DR	90024	5	138B157    25	4359013024	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM			PC Approved	11/13/2017 12:00:00 AM	ADDRESS	34.07629	-118.43071	Changes to LADWP service details - relocation of DWP transformer.  Approval for delta-E2 only.  (((Upgrade of (E) 600A 120/240V 1ph/3w service to a new 1600A, 120/208V 3ph/4w service for existing SFD and future theater.  New proposed generator backup for complete service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8117	15041-10000-04891	1306 N L. RON HUBBARD WAY	90027	13	147B197  1062	5543016019	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.09574	-118.29377	Title 24 plan check only.  Total area = 24,869 sq. ft. (outdoor Facade)Installation of exterior lighting.  Backroom plan check at request of applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8118	14041-10000-32751	13052 W RAYMER ST	91605	2	186B161   511	2327015016	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.2052	-118.41756	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 2904 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8119	15041-20000-09902	15027 W COPPER ST	91345	7	207B145    57	2615009036	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.26771	-118.45947	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system with 1 string of 11 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8120	19041-10000-34033	1624 N CAHUENGA BLVD	90028	13	148-5A187 217	5546008006	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.10071	-118.32937	Energy plan check for a restaurant T.I  reflect the actual build out on the floor plan. permit fee is paid under 18041-10000-44209.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8121	15041-10001-31644	719 E 25TH ST	90011	9	120A209   250	5131023022	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			Plans on Hold	09/30/2015 12:00:00 AM	ADDRESS	34.02228	-118.26008	EXPEDITED RSES PLAN CHECK PER APPLUICANT REQUEST.<<<<PV1, INSTALL NEW 3.18 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD--US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8122	07041-20001-27261	1717 N VINE ST	90028		148-5A187 104	5546004400							Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM			PC Approved	05/11/2010 12:00:00 AM	ADDRESS	34.10222	-118.32701	Plan check only for Delta 1 revisions. Palihouse RestaurantRequest for Modification to separate Fire Alarm system filed.New building ( P.C. 05041-20000-23388 ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8123	13041-20000-35942	8045 N VINELAND AVE	91352	6	189B173   144	2314006001	[Q]C2-1L-CDO, [Q]P-1L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.21699	-118.37053	T24 FOR EXISTING RETAIL. NEW CONNECTED LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8124	14041-20000-08695	14724 W VENTURA BLVD	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.15162	-118.45395	T.I. existing building.  Install general lighting.  Plan check for energy.Note: Permit is under a separation application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8125	13041-10000-15410	1751 N LAS PALMAS AVE 1-24	90028	13	150A185   354	5547002030	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Public Safety Only			06/12/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.10334	-118.3364	NEW FIRE WARNING SYSTEM FOR 5-STORIES 24UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8126	13041-20001-07994	8985 W VENICE BLVD CB-2	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			Corrections Issued	05/16/2013 12:00:00 AM	ADDRESS	34.02733	-118.39241	(((changes to original approved set of plans. delta 2 changes)))refer to 13041-10000-07994  for plan checkRENOVATION OF EXISTING STARBUCKS. CHANGE IN LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8127	13041-10000-00586	21045 W CALIFA ST	91367	3	177B105   101	2149002029	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.17741	-118.59196	PLAN CHECK ONLY FOR EMERGENCY LIGHTING IN A SINGLE STORY OFFICE SPACE PER INSPECTOR REQUEST (CHABAN, CAMERON - VAN NUYS BUILDING INSP)T24 EXEMPTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8128	17041-20001-45333	3649 N CROWNRIDGE DR	91403	5	162B141   421	2280009020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.13703	-118.47627	expeditepv1install rof mounted pv system sized 17.3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8129	12041-10000-21813	21601 W VANOWEN ST #100	91303	3	183B105   950	2138006045	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.1939	-118.60052	PLAN CHECK POWER AND ENERGY FOR DENTAL OFFICE ON PORTION OF GROUND FLOOR EXISTING TWO STORY BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8130	13041-20000-12706	14121 W WEDDINGTON ST	91401	2	171B153   298	2248019023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.1668	-118.44083	New rooftop photovoltaic system for a single-family-residence.  System is ungrounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8131	17041-10002-43722	13488 W MAXELLA AVE	90292		105B153    77	4212004032							Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	33.98592	-118.44252	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE CHANGING FIXTURE TYPE AND FIXTURE QUANTITY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8132	15041-20000-11811	2048 S BUNDY DR	90025	11	123B149   419	4259020018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.03327	-118.45451	$0 permit fee is due to Senate Bill SB-1222. PV2. ROOFMOUNTED SOLAR SYSTEM. LINESIDE TAP. SYSTEM SIZE: 180 KW  DC.( 672 ) SUNIVA 270W MODULES( 8 ) SMA STP20000-TL INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8133	10041-30000-11030	13445 W BEACH AVE	90292	11	108B149  1045	4230003045	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	06/14/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	33.9908	-118.44551	Revision to approved plan app # 09041-30000-14317 change was drawn on the plan as build reflecting wire change, new panel and new location of time clock. New permit will be for 50 amp panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8134	16041-30000-38101	16000 W SHERMAN WAY	91406	6	183B141   130	2224004007	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	12/03/2016 12:00:00 AM	ADDRESS	34.20098	-118.48156	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8135	13041-10003-05748	380 WORLD WAY Space T45	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM			PC Approved	11/20/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	UPDATED PLANS FOR REVISIONS TO THE PERMITTED SET OF PLANS-INCREASE IN LIGHTING SYSTEM AND DINING AREA;REVISED PANEL SCHEDULES((((((((((PROPOSED 709 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Petrossian).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8136	19041-20000-53392	2915 W EXPOSITION PL Unit #2	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM				NEW ROOF MOUNTED 2.56KW PV SYSTEM WITH 8 @ 320W PANELS AND A CENTRAL INVERTERS ON AN APARTMENT BUILDING FOR UNIT #2.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8137	18041-20000-23145	1902 E MARENGO ST #107-#108	90033	14	132A223    33	5201016003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.05756	-118.21009	Change of use from retail to office in (E) commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8138	12041-10000-03469	624 S GRAND AVE	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	02/16/2012 12:00:00 AM	PIN	34.04778206	-118.25563275	Replacement of light fixtures with led fixtures.  PLAN CHECK Only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8139	10041-10000-15746	1700 W 6TH ST	90017	1	132A205    65	5142009033	C2-2/C4-2/R4P-2/R5P-2	Central	Westlake		YES	2089.02	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	01/05/2011 12:00:00 AM		Permit Finaled	04/22/2011 12:00:00 AM	ADDRESS	34.05713	-118.27001	TI IN AN EXISTING RETAIL STORE (FOOD 4 LESS). PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8140	17041-10000-40563	18502 S NORMANDIE AVE	90248	15	060B197   152	6109006046	C1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	33.86281	-118.29904	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8141	18041-20001-47360	555 S MATEO ST 2ND FLOOR	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.03943	-118.23302	08-28-2019 Changes to an approved set of plans, Supplemental plan check only, to recheck plans due to changes to power and lighting floor plans and T24. Single line and panel schedules are unchanged.All permit under this plan check covered under Master application 18041-20000-47360	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8142	12041-10000-19469	17352 W MAGNOLIA BLVD	91316	5	171B133   330	2257014009	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.16533	-118.51153	PV1 - NEW 16.58KW PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS. ROOF MOUNTED SINGLE FAMILY HOUSE. EXISTING 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8143	19041-10000-50114	2328 N BRONSON HILL DR	90068	4	153A191   378	5587028002	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.11262	-118.31556	NEW PV-1 SOLAR SYSTEM. CONSIST OF 225 TESLA SRV3 ROOF TILES, (2) CENTRAL INVERTERS, (DELTA SOLIVIA 5.2  & 7.6)  AND (2) TESLA POWER WALL. SYSTEM SIZE IS 12.8KW AC & 13.15575KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8144	14041-10002-03738	862 S MAIN ST	90014	14	127-5A209 294	5145015002	[Q]C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	ADDRESS	34.04148	-118.25466	((5/7/2014- RELOCATED EMERGENCY LIGHTS. PHOTOMETRICS TO BE VERIFIED))change of use to coffee shopplan chk is for title 24(5/6/14) Change to approved set of plans (title 24 only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8145	10041-20000-07599	1048-1050 N KINGSLEY DR	90029	13	144B193   867	5537019008	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Apartment			04/26/2010 12:00:00 AM			PC Approved	05/18/2010 12:00:00 AM	ADDRESS	34.08991	-118.30313	New service of 600 amp for 4 existing units and for 5 new additional units attached to it. Existing permit under #09041-20000-21437 and #09041-2000-21437. Modification for multiple feeders to existing building for residential apartment has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8146	10041-10000-15436	14731-14735 W CALIFA ST	91411	2	177A149   147	2244009026	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.17771	-118.45439	New fire alalrm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8147	15041-20001-39349	7737 N ARCOLA AVE	91352	2	189B177   763	2405007001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM			PC Approved	12/11/2015 12:00:00 AM	ADDRESS	34.21143	-118.3532	"""EXPEDITED PER APPLICANTS REQUEST ""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.25 KW."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8148	16041-10000-08487	2379 N VENUS DR	90046	4	153B177   448	5569028032	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	PIN	34.11349184	-118.3663042	PV1 SFD TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM WITH 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8149	11041-10000-09793	14006 W RIVERSIDE DR SPCE #32	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.1. EXISTING RETAIL SPACE.  NEW TENANT TO OCCUPY THE SPACE.    REPLACING LIGHT FIXTURES.  NO NEW LOAD IS BEING ADDED.  PLAN CHECK IS FOR TITLE 24  AND EMERGENCY LIGHTS ONLY.  USING TAILORED METHOD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8150	14041-20000-28307	7653 N TEXHOMA AVE	91325	12	186B129    66	2202002019	RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.21006	-118.51549	$0 permit fee due to senate bill 1222 from 2012INSTALL ROOF MOUNTED PV SYSTEM SIZED 21.8KW INTERCONNECTED WIH MSP.(70) SUNPOWER 327W MODULES(4) POWER ONE INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8151	11041-10000-11833	8070 W MELROSE AVE	90048	5	141B177   622	5528009005	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			PC Approved	06/08/2011 12:00:00 AM	PIN	34.08349029	-118.36554017	TITLE 24 AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8152	17041-20001-46278	10960 W BELLAGIO ROAD	90077	5	141B149   247	4366001006	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	ADDRESS	34.07962	-118.4569	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.6.72kW ungrounded system.(24) EnPhase IQ6PLUS-72 microinverters.(24) 360W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8153	10041-10000-08227	15823 W MONTE ST	91342	7	225B141  1524	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	06/23/2010 12:00:00 AM	ADDRESS	34.31094	-118.47588	Plan check T-24 Energy (general/emergency) lighting for T1 of existing office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8154	15041-10000-38411	8 S BEVERLY PARK TER	90210	5	150B157   105	4386028019	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	PIN	34.10863771	-118.42225865	PV1 24kW AC ground-mounted system with (4) ABB: PVI-6000-OUTD inverters, (106) REC-275 modules, and (1) subpanel interconnecting through a main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8155	10041-20000-23039	20335 W SORRENTO LANE Building-7	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Apartment			11/18/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	10/19/2011 12:00:00 AM	ADDRESS	34.27829	-118.57701	Plan check for new 3-Story, 23-unit Apartment Building  (Type B). Building 7. Modification to seperate fire alarm system has been filed. Outdoor lighting under this application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8156	18041-10001-24597	3341 W 43RD PL	90008	10	114B185  1144	5024019906	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM			PC Approved	10/03/2018 12:00:00 AM	ADDRESS	34.00441	-118.33097	PLANCHECK ONLY FOR MINOR CHANGES TO FIREALARM PLANS. CHANGES ARE CLOUDED UNDER DELTA 2. PERMIT UNDER MASTER PERMIT. REPLACING FIREALARM PANEL AND 44 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8157	16041-30000-15834	15059 W LA MESA ST	91342	7	228B145   330	2502005008	RA-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.31988	-118.46068	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (25) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8158	14041-20000-08902	7026 N GREEN VISTA CIR	91307	12	183B093   301	2028021024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.1976	-118.64028	PV1 3.5KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(14)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8159	17041-20000-04796	11027 W BURBANK BLVD	91601	2	174B173   863	2337027017	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.17232	-118.37142	replace existing fire alarm panel.  install new 180 notification devices in guest rooms floors 2, 3 and 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8160	18041-10000-29638	19731 W BAHAMA ST	91324	12	195B117    32	2782038014	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.23334	-118.56327	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8161	14041-20000-27969	8680 W PICO BLVD	90035	5	132B169  1060	4303011002	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.05411	-118.38117	Plan check for energy only. Install new lighting (incl. emergency) in existing restaurant/market (including new addition area). 1,625sqft. Building permit filed prior to July 1st, 2014, so plan shall comply with 2008 Title-24 standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8162	10041-10002-00468	8700 W BEVERLY BLVD 9th floor	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	11/10/2010 12:00:00 AM	ADDRESS	34.07666	-118.3805	Replace existing 1DP and it's 600 ampere tap with a new 800 ampere distribution and 700 ampere tap.  This is done to allow for the two feeders to supply the new x-rays, due to lack of spaee, on the existing MSH , see previouly approved set of plans for clarification.  The feeders to the X-rays are reduced in AWG from the original approved set of plans.  There is no change in load on MSH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8163	17041-20000-31889	19100 W VENTURA BLVD STE A & B	91356	3	174B121   460	2163021008	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.17237	-118.54897	Plan check for power and energy.  TI/change of use from retail to medical office at suite A and suite B. New lighting (including emergency) - 2,340sqft.  Power plan check per article 517 for healthcare facilities.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8164	17041-10000-04265	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/12/2024 12:00:00 AM	ADDRESS	34.05134	-118.25661	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR EXISTING INTERIOR SPACE(NORTH TOWER EVENT CENTER) . SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR THE EVENT CENTER). TOTAL AFFECTED AREA IS 13551 SQ. FT. B#15016-10000-27914	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8165	15041-20001-00661	1338 E M ST	90744	15	033B213    69	7425018015	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	33.78926	-118.24656	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Grounded system.18  327W pv modules across three strings (6+6+6).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8166	11041-10000-26681	8500 W BEVERLY BLVD # 690	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM			PC Approved	01/09/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) RETAIL SPACE (952 SQFT)  at Premier Skin Care store;new lighting and circuits . Plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8167	13041-10000-08079	101 S LA BREA AVE	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.07338	-118.34425	FULL PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE OFFICE TO RETAIL/RESTAURANT, TIE LOTS TOGETHER PER BUILDING PERMIT APPLICATION. USING EXISTING SERVICE WITH NEW LOADS. 23436 SQRFT INDOOR. 685 SQRFT OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8168	16041-10000-14573	12919 W VICTORY BLVD	91606	2	180B161  1034	2326016018	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.18684	-118.41451	T-24, PC FOR ENERGY ONLY. TI TO AN (E) RESTAURANT (MCDONALDS RESTAURANT). SCOPE INCLUDES REPLACING FLOURESCENT FIXTURES WITH LEDs. TOTAL AFFECTED AREA IS 2023 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8169	19041-30000-45372	5921 E ECHO ST	90042	1	151-5A229 158	5492015025	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	03/15/2024 12:00:00 AM	ADDRESS	34.11001	-118.18961	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITTS, AND CONTROLS. TOTAL AFFECTED AREA IS 3363 SQFT. ((B#19016-10000-35110)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8170	14041-20000-28107	3016 E ISABEL DR	90065	1	148-5A217 137	5455007005	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.10212	-118.23349	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW. Transformerless inverter, 12 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8171	13041-20000-09323	400 S HOPE ST flr 25	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for energy and emergency lighting. Commercial High-rise. 25th floor. CBRE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8172	17041-20000-07226	1312 W 8TH ST	90017	1	130-5A205 323	5143001014	C2-2	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM			Reviewed by Supervisor	03/28/2017 12:00:00 AM	ADDRESS	34.05033	-118.26963	PLANCHECK FOR POWER AND ENERGY. NEW 6 STORY 36 UNIT MIXED USE APARTMENT BUILDING . Fire alarm variance has been submitted.Building Permit # 15010-10000-02768	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8173	16041-20000-17716	1201 W 5TH ST SUITE 500	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.05429	-118.25967	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES AT 5TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8174	19041-10000-48842	610 E 59TH ST	90001	9	105B205   172	6007005001	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.98705	-118.26446	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8175	13041-10001-26331	22674 W CRESPI ST	91364	3	171B097   777	2075013042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.16342	-118.62017	][][]EXPEDITED PER APPLICANT REQUEST ][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON-STANDARD PLAN , XFORMERLESS SYSTEM; SYSTEM SIZE IS 5.145KW DC WITH (21) MODULES: TRINA #TSM-245PA05.18(1) POWER-ONE #AURORA PVI-3600	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8176	19041-10000-02789	2236 W MERTON AVE	90041	14	162A221   199	5686021056	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.13784	-118.21571	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8177	11041-20000-08133	1800 S AVENUE OF THE STARS 3rd Floor	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	10/21/2011 12:00:00 AM	ADDRESS	34.06095	-118.41786	T.I. to existing high rise building of the entire 3rd floor.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8178	15041-10001-41339	1141 W 2ND ST	90012	1	133-5A209 224	5152009901	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	12/06/2021 12:00:00 AM	ADDRESS	34.0588	-118.25625	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE SERVICE UPGRADE TO 1200 AMPS, ADDING CONDUIT SEALS, AND ADDING PULL BOXES ON THE SINGLE LINE DIAGRAM. ALSO CHANGING ENGINEER ON RECORD FOR CHANGES UNDER DELTA 2. TOTAL SYSTEM SIZE 276KW AC. USING TOTAL OF 1107 MODULES. THIS IS A PV ONLY SERVICE (FEED IN TARRIF).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8179	09041-10001-24166	500 W WORLD WAY MCP-01	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	05/03/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	"T.I. /  SABS baggage handling system.  Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. P/check for total of 10 conveyor systems, MCP-01 thru MCP-10.  Inspection permit for MCP-01 only. (See ""Application Comment"")"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8180	17041-10000-12663	9184 N SAN FERNANDO ROAD	91352	6	198B169   147	2538008022	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.23651	-118.38992	PC for energy only, Indoor  title-24. Removing HID fixtures and installing new LED ones. Area: 16,625 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8181	11041-10000-04935	8500 W BEVERLY BLVD # 684	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Finaled	06/27/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT IN RETAIL STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTnote that previous plan chk  and permit was on 11041-10000-01376 ; new lay out of the space and revised lighting system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8182	18041-10000-43974	380-384 WORLD WAY MSC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Power plan check for a new LAX terminal, Midfield Satellite Concourse.  Scope includes multipule motor load under each ckts feeding from submotor control panel, and control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8183	13041-10000-12163	101 N LA BREA AVE	90036	5	138B181   828	5513002001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/16/2013 12:00:00 AM	ADDRESS	34.07377	-118.34423	parking lot for retail stores,  out door title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8184	15041-10000-01918	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Issued	06/26/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	Installation of new roof mounted solar PV array.  Total system size = 100 kWac.  452 Total modules (Sunpreme SNPM GxB 280) with 5 inverters (SMA STP 20000 TL-US) permit fee zero due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8185	19041-20000-03586	12919 W SATICOY ST	91605	2	186B161   432	2303021012	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	04/07/2020 12:00:00 AM	ADDRESS	34.20689	-118.41507	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to an auto repair shop. Total lighting area = 1,750 sq. ft.Note: Building permit has been issued under 18016-20000-21584	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8186	13041-20000-35450	14823 W LASSEN ST	91345	7	201B149   182	2647010018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	34.2501	-118.45506	PV1 TRANSFORMERLESS SYSTEM. SOLAR EDGE. TOTAL SYSTEM SIZE 5KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8187	19041-20000-42816	5320 N LOUISE AVE	91316	5	171B133   125	2258005037	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.16768	-118.50964	PV1.  Install 23.100 kW DC roof mounted grid tied PV system.  (70) modules with (2) 7.6 kW rated inverters.$0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8188	19041-10000-46717	6907 N QUAKERTOWN AVE	91306	3	183B113   655	2135029022	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			PC Approved	11/13/2019 12:00:00 AM	ADDRESS	34.19595	-118.57001	PLAN CHECK ONLY. NEW PV1 INSTALLATION.  6.4KWdc (6.0KWac) USING QP305 MODULES, 21 SE P320 POWER OPTIMIZERS & SE6000H-US CENTRAL INVERTER. CONNECTED TO A 200Amp EXISTING SERVICE.PERMIT FEE PAID UNDER 18041-90000-42351	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8189	16041-10000-32606	4760 W PICO BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.04831	-118.33938	PC FOR T24 ENERGY ONLY. ADDITION OF STARBUCKS KIOSK IN EXISTING RALPHS STORE. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8190	19041-20000-47626	11300 W TUXFORD ST	91352	6	195B173   307	2408024015	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.23025	-118.37686	800A 240/120V 3ph-4w service, distribution, power, and lighting for commercial space.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8191	17041-10000-08688	3852 S MCLAUGHLIN AVE	90066	11	114B157  1023	4214013008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Issued	03/17/2017 12:00:00 AM	ADDRESS	34.0075	-118.42348	Plan check for PV roof mounted system. System size: 6.0kW with 20 modules and 1 inverter(5.0kW).Solar edge equipment(SE6000a-US) with power optimizers(p300).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8192	15041-10000-43217	540 S SAN PEDRO ST	90013	14	127-5A213 362	5147024025	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Closed	10/11/2017 12:00:00 AM	ADDRESS	34.04305	-118.24443	CHANGE OF USE AND TENANT IMPROVEMENT TO CONVERT PORTION OF EXISTING PRINT SHOP TO PRIVATE MEDICAL OFFICE ON 1ST STORY FLOOR LEVEL PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8193	12041-10002-16520	645 S LA BREA AVE	90036	4	135B181   770	5508007022	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.06359	-118.34421	Plan check for Delta 4 revision. Remove subfeed panel A to panel D, refeed panel D to switchboard, remove pull section, relocate A/C#3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8194	15041-10001-21196	300 S SANTA FE AVE unit g	90013	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	Changes to approved set.  Change of light fixtures in storage and fitting rooms.  Change of track lighting manufacturer.  (((FIRST TENANT IN COMMERCIAL SPACEFULL PLAN CHK)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8195	16041-20000-17807	557 N CHAPALA DR	90272	11	126B129   732	4411011019	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.03913	-118.52118	Plan check for a PV1 roof-mounted PV system. System size is 7.7 kWac and consists of (24) AC modules and (1) load center. PV system is interconnecting with a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8196	15041-10000-29135	100 WORLD WAY SPACE 158	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR ENERGY. T.I. TERMINAL 1 OF LAX. EXISTING RETAIL STORE. TOTAL AREA 432 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8197	18041-20001-00131	12001 MIRABEL WAY	91326	12	216B109   172	2701081021	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	PIN	34.29061503	-118.58245755	Plan check for lost set of plan. pv1install roof mounted pv system sized 4.8kw interconnected with msp.  standard plan.Fess $53.68 due California Senate Bill 1222 and Assembly Bill 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8198	15041-20000-13471	333 S GRAND AVE SUITE 2800	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Tilte 24 only, replacing existing light fixtures with new fixtures and reconnected to existing circuit and provide new recepticles for new room layout. Total area: 768 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8199	11041-20000-21634	127 S SAN VICENTE BLVD Bulletin-106TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta # 106 TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8200	10041-10000-21802	19600 W PLUMMER ST	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.2426	-118.5602	New 6 level parking structure.  Electrical supplied by a feeder service.  REF.#10042-100019439.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8201	16041-10000-11963	10250 W SANTA MONICA BLVD 1005-Javiers	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	10/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	TENANT IMPROVEMENT TO JAVIERS RESTAURANT TO INCLUDE OUT DOOR DINING WITH TRELLIS ADDITION. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8202	13041-20000-35784	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	33.97749	-118.41246	POWER AND ENERGY FOR FIRST TWO FLOORS OF NEW BLDG. CORE AND SHELL. 2500AMP SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8203	10041-20000-09009	6600 N TOPANGA CANYON BLVD #1022	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	08/09/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check power and energy for TI (Best Buy Mobile) #1022 at Westfield Topanga MallREQUEST FOR MODIFICATION TO SEPARATE FIRE ALARM SYSTEM FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8204	17041-20000-32217	3356 N EASTERN AVE	90032	14	142-5A233 174	5218013010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.08505	-118.1779	pv2install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8205	12041-20000-17249	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL, [Q]R3-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00, 1204.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.2215	-118.42999	Replace/upgrade of existing HVAC equipment of Medical building (Kaiser Permanente) with new total connected load exceeds 400A .  Plan check for power only.    Building is Not State Licensed, NOT checked for OSHPD 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8206	13041-10000-30617	265 S GRAMERCY PL	90004	4	135B193   187	5516016015	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.06924	-118.313	PV1, ROOF-MOUNTED SOLAR ARRAY ,INTERCONNECTING WITH NEW 200A SERVICE(SERVICE UPGRADED FROM 100A) IN SINGLE-STORY HOUSE. MICROINVERTER SYSTEM ; SIZE IS 7.5kW DC AND 6.48 kW AC, WITH (30) MODULES ( HANWHA HSL60P6-250) , (30) ENPHASE M215 MICROINVERTERS.IMPORTANT: existing permit is under 13041-20000-22302 which was initially a central inverter plan; charges for 30 modules, (2) inverters were already accounted for and shall not be charged again upon final fee period.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8207	16041-10001-12066	5015 N EAGLE ROCK BLVD	90041	14	162A221   218	5686021030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.13746	-118.21479	Changes to an approved set, scope includes the built out in office spaces only. Adding new ckts and expanding the floor plan of the scope.  Total sq. ft.  16,300*****Previous Work Description*****FUL PC FOR POWER AND ENERGY. INTERIOR TI FOR EXISTING  3 STORY OFFICE BUILDING; WORK INCLUDE change of use of one of the office tenant space at ground floor to restaurant with new mezzanine inside (Core and shell only with tenant 301). SCOPE INCLUDES 4 NEW 75KVA TRANSFORMERS,  AND 15 NEW SUBPANELS FOR TENANT SPACES. TOTAL AFFECTED AREA IS 7057 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8208	17041-10000-30923	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.09918	-118.32644	PC FOR NEW WALL SIGN IN MIXED USED BLDG. TITLE 24 ENERGY ONLY. TOTAL AFFECTED SIZE 1250 SQ.FT.BLDG# 17048-10000-02244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8209	18041-20000-48154	16250 W VENTURA BLVD	91436	5	168B137   430	2284003027	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	05/04/2020 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	ADDRESS	34.15668	-118.48715	Plan check for Title 24 only for lighting inside Mechanical Room, load less than 400A, Total area: 230 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8210	17041-10003-19302	380-384 WORLD WAY MSC-F/A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	12/29/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to an approved set of plans. All changes have been noted on delta 6. Changes include the removal and addition of devices noted on device legend. Notes 40,41,42 have been added to all pages. Fire alarm design changes to permitted set of plans ; Changes are the addition of VLF-250 and VLF-500 AIR SAMPLING SMOKE DETECTORS; CHANGES ARE CLOUDED AND MARKED AS DELTA 5.LIST OF SHEETS HAVING THE CHANGES ARE WITH THE SET OF PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8211	19041-10000-10319	206 E 24TH ST	90011	9	121-5A207 262	5127033021	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.02585	-118.26623	PC for PV. system includes 12 Modules (solarCity SC325) , 1 Central inverter (Solivia 3.8), 1-125 Load center , 1 ESS (Tesla Power wall)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8212	15041-20000-04139	14344 W SHERMAN WAY	91405	6	183B149    71	2217006008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Issued	02/11/2015 12:00:00 AM	ADDRESS	34.20103	-118.44591	PC FOR T24 ENERGY ONLY. THIS IS A OCCUPANCY WITH NO ADDITIONAL WORK INVOLVED. T24 OKAY. NEW LIGHITNG TO REPLACE EXISTING. LESS THAN 85% ALLOWED DENSITY. EXISTING CONTROLS OKAY. NO OTHER SCOPE INVOLVED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8213	19041-10000-19475	4000 S FIGUEROA ST	90037	9	115-5A201 112	5019026001	C2-1L	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Info Complete	05/22/2019 12:00:00 AM	ADDRESS	34.01082	-118.28253	T-24 only for remodel of restaurant. area of scope is 1,476sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8214	17041-20001-20945	11600 N ELDRIDGE AVE	91342	7	213B169  1018	2530001019	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.28073	-118.38369	9.25.2017 - Plan check for changes to approved set. Update plans to reflect new Annunciator (ANN), replacing existing ANN. Change clouded delta 2. Only change.======PC for new fire alarm system with 351 devices, 1 FACP and 7 RPS panels in a two story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8215	13041-10001-17753	3465 N BEVERLY GLEN BLVD	91423	4	159B149   272	2275027019	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.13338	-118.44836	][][]CHANGES MADE TO AN APPROVED SET OF PLANS; CUSTOMER UPGRADED THE SYSTEM SIZE FROM 3.5 KW DC TO 3.57 KW DC WITH THE USE OF ET-P660255WB (255W) MODULES; EXISTING MODULES WERE 250W MODULES (REC 250 PE). FEES CHARGED PER APPLICANT REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8216	11041-10000-15347	18916 W ROSCOE BLVD	91324	12	192B121   835	2104036038	[Q]C1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/21/2011 12:00:00 AM	ADDRESS	34.22042	-118.54547	TI TO AN EXISTING 7-ELEVEN.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8217	18041-20002-29500	16644 W DEMARET PL	91344	12	216B137    98	2609010002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.29105	-118.49525	09-13-2018 Changes to an approved set to an approved set of plan. Changes include PV modules relocate on roof. All changes has been clouded.Fees $0.00 due to California Senate Bill 1222 and Assem bill 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8218	17041-20000-24226	12811 W FOOTHILL BLVD	91342	7	216B161    22	2514004029	M1-1-CUGU	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.29241	-118.41375	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 68.3 KW$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8219	16041-10001-03176	22915 W VICTORY BLVD	91307	12	180B097   434	2038040031	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM			PC Approved	06/07/2016 12:00:00 AM	ADDRESS	34.1866	-118.62549	PC FOR POWER AND ENERGY.  SUPLEMENTAL TO APPROVED SET OF PLAN , CHANGES UNDER DELTA 1.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8220	19041-20000-24183	5501 N LAUREL CANYON BLVD 1-46	91607	2	174B165   881	2347015001	R3-1, [Q]C1.5-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			07/05/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	04/07/2023 12:00:00 AM	ADDRESS	34.17052	-118.39682	FULL PLAN CHECK. SCOPE OF WORK INCLUDES NEW 1600A SERVICE, (50) 0-200A PANELS, (3) 201-600A PANELS, (10) 601-1200A PANELS, 30 HP MOTOR, 15HP MOTOR, (4) 7.5 HP MOTOR, (2) 5HP MOTOR, AND (564) BRANCH CIRCUITS. T24 INCLUDED TOTAL SQUARE FOOTAGE = 63226 SF. BUILDING PERMIT ISSUED UNDER B#07010-10002-05387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8221	19041-10002-14680	189 S THE GROVE DR #J1A	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	Change to an approved set by modifying the power and lighting plan. (1) panel be removed from single line, and ckts also being relocated. All changes under delta-7 only.(((PC PWR AND ENERGY FOR FIRST TIME TI. EXISTING 600A,480/277V, 3PH SERVICE. SCOPE OF WORK AREA 11,505SF.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8222	14041-10001-26838	6415 W RODGERTON DR	90068	4	157-5A189 269	5582012016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.12396	-118.32286	Expedite per customer request(((PV1 9.66KW roof-mounted system including (28) Sunpower X21-345 modules and (2) SB5000TL  inverters interconnecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8223	19041-20000-05254	14751 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.17767	-118.45487	ti to an existing commercial building.  adding new lighting new controls to existing/new panel.  newly connected load < 400 amps.  plan check for power and energy indoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8224	15041-20000-24335	237 S LOS ANGELES ST	90012	14	129A213    20	5161026905	C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Issued	08/12/2015 12:00:00 AM	ADDRESS	34.04946	-118.24419	PLANCHECK FOR TEMPORARY SERVICE. TWO 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8225	15041-10000-13136	8500 W BEVERLY BLVD #788	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a retail T.I  (Space #788) ; scope includes new equipment , and new lighting. Total area is 2138-SQ feet. plan check is under Tailored method.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8226	16041-10001-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.04771	-118.46271	CHANGES TO APPROVED SET OF PLANS. CHANGED NOTED DELTA A ON DRAWINGS. CHANGES TO LIGHTING LAYOUT ON A COUPLE PAGES. PROVIDED UPDATED T24. PERMIT STILL COVERED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8227	13041-10000-16473	750 S LAMAR ST gate bldg	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Issued	12/23/2014 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (1.) existing gate building modifications  (lighting modifications) BUILDING.Note: this includes all of the sectionalizing enclosures se-10/9/8/7/6/5/4/3/2, transformers 13.2kv T-1/4/5/8, new gate building generator, and units to existing branch circuits.see comments for additional information:FEES TO BE RECALCULATED. INVESTIGATION FEE DUE. 30 day time limit permit. located in a Community Redevelopment Agency (CRA).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8228	11041-10000-07591	12301 W WILSHIRE BLVD Ste 201	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM			PC Approved	04/14/2011 12:00:00 AM	PIN	34.04277409	-118.46969044	T.I.  REPLACING LIGHT FIXTURES AT AN EXISTING DERMATOLOGY OFFICE.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8229	18041-10000-24172	2500 S SIGNAL ST Berth 68	90731	15	009B201    60	7440037902		Harbor				9800.31	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	33.72053	-118.27222	PLAN CHECH FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 145 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8230	18041-10000-38039	1633 W CORDOVA ST	90007	1	126B197   761	5075036017	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.03916	-118.29271	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8231	17041-10000-08000	6709 W SELMA AVE	90028	13	148-5A185 275	5547014039	C4-2	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Closed	12/11/2019 12:00:00 AM	ADDRESS	34.09981	-118.3367	PC FOR POWER ONLY. TEMPORARY POWER FOR A CONSTRUCTION SITE. SCOPE INCLUDES ADDING NEW 600A 480/277V 3 PHASE 4 WIRE SERVICE, NEW PANELS, AND NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8232	13041-20000-15941	17133 W NANCE ST	91316	5	165B133   295	2292002013	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	34.14858	-118.50488	New Ungrounded PV System over 10kw.  Plan check is only for the PV System, NOT for derating the main breaker.  Plan check only, permit is on #13041-20000-14973	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8233	16041-10000-06550	2049 S CENTURY PARK EAST flrs 21-23	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Issued	04/14/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24, TI TO AN OFFICE ON PARTIAL 21ST, 22ND, AND 23RD FLOORS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 16060.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8234	15041-20001-14204	1355 N GARDNER ST	90046	4	147B177  1280	5550024015	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			05/11/2015 12:00:00 AM			Reviewed by Supervisor	05/19/2015 12:00:00 AM	ADDRESS	34.09593	-118.35301	expedite feesInstallation of new roof mounted solar PV array.  Total system size = 15.2 kWac. system uses 2 inverters. system is single phase 240v. total of 60 pv modules. solar clearance has been provided from building permit. this is net meter project. commercial rooftop of 18 unit apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8235	14041-10001-16357	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Apartment			07/30/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	IN THE CORRIDORS OF THE BUILDING, WALL SCONES HAVE BEEN ADDED  AT EACH UNIT ENTRY ;REVISED TITLE 24 CALCULATIONS; THREE PANELS HAVE BEEN MODIFIED -NO NEW LOADS ARE ADDED(((((((((PLANCHECK FOR POWER AND ENERGY.   New 4-story, 338 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8236	15041-20000-27361	333 S HOPE ST 46th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 only in existing space. Total indoor area: 24,010 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8237	10041-20000-13649	5543 N TAMPA AVE	91356	3	174B117   376	2163015024	R1-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.17205	-118.55361	Plan check T-24 Energy for outdoor parking lot. Existing service, new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8238	14041-20002-09566	16357 W PLUMMER ST	91343	12	198B137    32	2677020013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2014 12:00:00 AM			PC Approved	05/08/2014 12:00:00 AM	ADDRESS	34.24309	-118.48919	Modifications to approved set: changes to module layout on rooftop.  $0 submittal fee is due to Senate Bill SB-1222.(((PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8239	16041-10000-28390	1717 S SOTO ST	90023	14	118-5A221  99	5169016001	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.01756	-118.22029	FULL PC FOR POWER AND ENERGY ONLY. SCOPE INCLUDES A NEW600A 120/208 3PHASE 4 WIRE SERVICE, 4 NEW SUBPANELS, NEW HVAC EQUIPMENT, AND NEW LIGHTING FOR A NEW CONVENIENCE STORE (7-ELEVEN). TOTAL AFFECTED AREA IS 12984 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8240	12041-10000-05739	4557 N GRIFFIN AVE	90031	1	147A225   150	5303004027	[Q]RD3-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	05/29/2012 12:00:00 AM	ADDRESS	34.09512	-118.20206	NEW PV INSTALLATION. STANDARD PLAN CHECK. ROOF MOUNTED 8.385KW. 2-STORY SINGLE FAMILY DWELLING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8241	13041-20000-25307	6420 W WILSHIRE BLVD #900	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.06365	-118.36922	T24 FOR EXISTING OFFICE SPACE. RELOCATING SOME LIGHTS ON SUITE 900. TOTAL SQRFT 4049	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8242	13041-10000-34755	1188 S SAN PEDRO ST SUITE K	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	PIN	34.03375994	-118.25280059	Remove HID light fixtures and replace with new fluorescent fixtures in existing retail space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8243	18041-10000-08618	5031 N ALONZO AVE	91316	5	171B129   362	2182007002	RA-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.16167	-118.52046	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8244	13041-10001-29466	2259 N LINDA FLORA DR	90077	5	153B145   122	4377010003	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.11461	-118.46416	Expedited plan check per applicant request.(((((PV1, Installing roof-mounted solar array, interconnect with main panel. System size: 12.0 KW DC.48 panel and 720 sq ft.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8245	14041-10000-24354	523 W 6TH ST 8 & 9TH-FLOOR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 8TH AND 9TH FLOOR. HIGH RISE. 3216 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8246	16041-10000-23960	2409 N GRIFFITH PARK BLVD	90039	4	148-5A205  38	5432003004	RD2-1VL, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Apartment			07/12/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.10303	-118.27254	PC FOR POWER AND ENERGY. PROPOSED 3 STORY, 13 UNITS,  RESIDENTIAL APARTMENT BUILDING OVER SEMI SUBTERRANEAN PARKING.  SERVICE SIZE 1200 A. 4 TYPICAL UNITS.B # 16010-10000-02240	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8247	19041-20000-39263	5819 N BECKFORD AVE	91356	3	174B117    61	2156004006	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.1765	-118.55173	PV1 PLAN CHECK ONLY PER INSPECTOR'S REQUEST FOR NEW ROOF PV SYSTEM ON EXISTING SFD. 10.88KW DC/ 9.86 KW AC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH MICROINVERTERSPERMIT PAID UNDER 19041-90000-36633	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8248	19041-20000-01972	5757 W WILSHIRE BLVD 3rd Floor	90036	4	135B177   594	5508015009		Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.06259	-118.35341	Corridor and elevator lobby improvements on 3rd floor of (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8249	18041-10001-35477	3645 N LOWRY ROAD	90027	4	154-5A203 149	5592010004	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.1178	-118.27765	FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 10.6 KVA SYSTEM CONSISTING OF 2 INVERTERS (SE7600A-US & SE3000A-US) AND 43 MODULES (P320 OPTIMIZERS) WITH DERATED MAIN BREAKER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8250	16041-10000-38142	718 N HUDSON AVE	90038	4	141B185   494	5533035019	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			10/27/2016 12:00:00 AM	11/13/2019 12:00:00 AM		Issued	11/13/2019 12:00:00 AM	ADDRESS	34.08398	-118.33192	Plan check for power and energy.  New 5 story 23 unit apartment building with 1,600A service.     Building permit #16010-10000-04962	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8251	11041-10000-03364	6303 N OWENSMOUTH AVE 2nd&7th-floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	05/03/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI IN AN EXISTING OFFICE. EPC IS FOR T24. (All circuits existing to remain)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8252	11041-20000-05393	5250 N LANKERSHIM BLVD 6TH  FLR	91601	4	171B173  1421	2350018090	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	ADDRESS	34.16668	-118.37545	PLAN CHECK T24 ENERGY/EMERGENCY FOR TENANT IMPROVEMENT ON THE 6TH FLOOR SADA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8253	19041-20000-25390	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.27455	-118.56289	Plan check for PV roof mounted system, PV syste size: 215.6KW DC, 166.6KW AC with 616 PV Modules and 2 inverters(100KW and 66.6KW)Fees $0.00 due to California Senate Bill 1222 and AB 1414Note: 2 Structure  under same address. This is Sanctuary Building. There 2 Building permit number: 19016-20000-20082, 19041-2000-25384	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8254	12041-20000-20732	2566 W SAN FERNANDO ROAD	90065	1	150B213   435	5457002013	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			09/04/2012 12:00:00 AM			Reviewed by Supervisor	11/08/2012 12:00:00 AM	ADDRESS	34.10836	-118.24175	Existing building with new service and lighting.  Check for electrical and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8255	19041-10000-42712	11150 W SANTA MONICA BLVD	90025	11	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D, [Q]C2-1XL	West Los Angeles	Brentwood - Pacific Palisades, West Los Angeles	Westside	YES	2628.02	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	03/24/2020 12:00:00 AM		Issued	03/24/2020 12:00:00 AM	ADDRESS	34.04704	-118.44563	Energy plan check for a T.I., Scope includes new lighting and equipment with a total lighting area of 296-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8256	11041-20000-05879	2000 N HYPERION AVE	90039	4	147A203   172	5431002007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	PIN	34.09784908	-118.27452114	PRESCHOOL FIRE ALARM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8257	14041-10001-09797	11281 W HUSTON ST	91601	2	168B173   101	2353016016	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			09/15/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.16001	-118.37716	[[[9/15/14    SUPPLEMENTAL  PLANCHECK FOR ADDITION OF 6 FIRE ALARM DEVICES PER REQUEST.]]]]]NEW FA  FOR 8 UNIT APT. 3 story R-2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8258	13041-10001-33138	20100 W VIA CELLINI	91326	12	219A115   344	2701039011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.2941	-118.57082	Expedite RSES plan check per applicant request.[][][]PV1, Install 8.75 kw DC roof-mounted solar array, interconnect with the service panel.(2)Transformerless inverter(s):Solaredge SE3000A-US and Solaredge SE5000A-US. (35)modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8259	18041-20001-24403	17312 W SUPERIOR ST	91325	12	201B133   435	2755008005	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.24655	-118.51197	08/02/2018 Changes to an approved set of plans. (3) modules have been added to the PV system. Inverter ratings have remained the same.*****Previous Work Description*****pv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8260	17041-20000-28076	14919 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29465	-118.45593	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8261	10041-10000-08558	758 E FLORENCE AVE	90001	9	102B205   820	6023002015	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	33.97459	-118.26099	IN EXISTING RESTAURANT, REPLACING MOST OF THE LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8262	10041-10000-01987	6721 W HOLLYWOOD BLVD	90028	13	148-5A185 112	5547010001	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			02/04/2010 12:00:00 AM	02/12/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	34.10172	-118.33671	TENANT IMPROVEMENT IN EXISTING RESTAURANT-PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8263	16041-20000-39083	6263 N TOPANGA CANYON BLVD	91367	3	177B101    20	2146001025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	11/01/2021 12:00:00 AM	ADDRESS	34.18482	-118.60621	New 7 story mixed use building with 2 subtarranean levels of parking. Includes (343) dwelling units, (4) guest rooms, and commercial tenant spaces. There are 5 services - (4) 2500A and (1) 2000A 208Y/120V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8264	15041-10000-07694	9021 N TAMPA AVE	91324	12	195B117    26	2783028009	(Q)C2-1, C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.234	-118.55383	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8265	12041-20000-13697	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	34.05494	-118.23752	T24 lighting plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8266	18041-20000-43866	3301 N LONGRIDGE TER	91423	4	159B161   304	2385010001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	34.13006	-118.41882	pv1install roof mounted pv system sized 11.2KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8267	17041-20000-21525	735 S FIGUEROA ST	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM			Corrections Issued	06/26/2017 12:00:00 AM	ADDRESS	34.04878	-118.26079	Plan check for energy only. TI - new track lighting for commercial retail (Target). 18,813sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8268	16041-10000-26516	10000 S VERMONT AVE	90044	8	091-5A199 131	6054009029	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	33.94531	-118.29139	PLAN CHECK FOR POWER ON A HAZARDOUS AREA.  INSTALL USTS (UNDERGROUND STORAGE TANK) AND FUEL DISPENSER AT THE NEW 7 ELEVEN STORE WITH GAS STATION(B# 16020-10000-02157). TITLE 24 (2054SQ. FT.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8269	16041-10000-15344	633 W 5TH ST LEVEL 4	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	TI TO AN EXISTING COMMERCIAL BUILDIGN. ADDING LED LIGHT, POWER FOR SIGNAGE & (1) RECEPTACLE. PLAN CHECK FOR TITLE 24 ONLY. TOTAL AREA 385 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8270	17041-20000-08121	17742 W RAYEN ST	91325	12	195B129   252	2768012007	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.23185	-118.52159	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 150A. 15.2kW ungrounded system [7.6*2]. (63) 280W pv modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8271	19041-10000-37458	5353 N BALBOA BLVD STE  202	91316	5	171B133    38	2258027016	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.16853	-118.50129	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8272	16041-20000-06709	4151 W PROSPECT AVE STAGE 7	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Replacement of dimmer distribution panel.  New lighting for electrical room.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8273	11041-10000-05252	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM			PC Approved	03/17/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24 FOR T.I. IMPROVEMENT TO AN EXISTING HIGH-RISE BUILDING.  OVER THE COUNTER PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8274	15041-20000-15265	18840 W VENTURA BLVD 100	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.17186	-118.54425	Plan check for power and Title-24 (energy).  Total area = 5,510 sq. ft.T.I. to existing medical office.  Addition of new switchgear section and associated power distribution system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8275	14041-10000-12570	1225 S LONGWOOD AVE	90019	10	129B181   186	5084024022	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.0526	-118.34059	Install roof-mounted solar array interconnect with main panel.System size = 2.72 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8276	10041-10000-24457	10006 S BROADWAY	90003	8	091-5A203 121	6053022008	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Apartment			12/08/2010 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Finaled	12/09/2011 12:00:00 AM	ADDRESS	33.9453	-118.27796	NEW 4 STORY, 16 UNIT APARTMENT BUILDING. VARIANCE FORM WAS SUBMITTED FOR THE FIRE LIFE SAFY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8277	18041-20000-33421	20605 W CHESTNUT CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.29252	-118.58382	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8278	19041-20002-00212	14150 S FIGUEROA ST	90061	15	075B201    42	6132044014	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Closed	11/12/2019 12:00:00 AM	ADDRESS	33.90273	-118.28255	11-01-2019 Changes to an permitted set of plan, Changes include fild revision, conductor sizes, circuit breaker size, feeder length, 2 new panels. All changes has been clouded as delta 2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8279	18041-20001-38477	18784 W TRIBUNE ST	91326	12	207B121   150	2717023026	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/24/2018 12:00:00 AM	ADDRESS	34.26668	-118.54296	expeditepv1install roof mounted pv system sized 15.5KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8280	12041-20000-01295	11740 W SAN VICENTE BLVD #107	90049	11	129B145    75	4265006074	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Info Complete	02/23/2012 12:00:00 AM	ADDRESS	34.05308	-118.4669	T.I. to existing retail space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8281	14041-10000-03365	11111 W SANTA MONICA BLVD SUITE 850	90025	5	132B161   133	4315019005	C2-2-O, M1-1-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES ON SUITE 850 ON THE 8TH FLOOR. 5381 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8282	19041-20000-16691	22135 W ROSCOE BLVD LOT #7	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	pv1install roof mounted pv system sized 2.0KW AC interconnected wirth msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8283	17041-10000-40158	12067 W FOOTHILL BLVD	91342	7	213B165   562	2531006009	[T][Q]MR1-1-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.05	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.27837	-118.39887	Remove HID fixtures and replace with new LED fixtures  T-24 only21300 SQ. FT OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8284	18041-20000-41141	9401 N DE SOTO AVE	91311	12	198B109    69	2746008007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM			PC Approved	10/26/2018 12:00:00 AM	ADDRESS	34.24091	-118.58876	TI to (E) warehouse space. Plan check for energy.  20,500 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8285	15041-10000-02429	9270 N KEWEN AVE	91352	6	198B165   143	2629013067	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.23823	-118.40142	Plan check for a PV1 roof-mounted PV system. System size is 7.8 kWac. System consists of (2) inverters and (35) modules. Main service panel is being upgraded to 225 A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8286	17041-20000-05839	21777 W VENTURA BLVD C&D	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.16858	-118.60238	Plan check for energy only. Relocate and remodel existing bathrooms. Expand existing office suite 252 to create more office space. New lighting and receptacles. 524sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8287	15041-10000-21832	437 S HILL ST	90013	14	129A211    13	5149028004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.0495	-118.2514	NEW 313 UNIT 8 STORY MIXED USE APARTMENT BUILDING,  SERVICE >1200 AMPS.   TOTAL SQ. FT. 258752.  FULL PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8288	15041-10000-41450	342 W PICO BLVD	90015	14	126A207   204	5134025042	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.03865	-118.26426	CHANGE OF USE FROM RETAIL TO CAFE SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8289	15041-20000-22321	812 W 165TH PL	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	33.88061	-118.28977	Plan check for Title 24 only. Project site is an existing charter school. Project scope is outdoor lighting. Total outdoor lighting area = 10,820 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8290	18041-20001-19733	11840 W FOOTHILL BLVD UNIT 'D'	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.27347	-118.39434	12/17/2018changes to an approved set of plans.  changes to reflect exisiting field conditions.  ((((First time tenant for commercial tenant space.  Existing distribution equipment.  2140 sq ft.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8291	10041-10000-22102	310 W WASHINGTON BLVD BLDG #7	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 6 UNIT TOWN HOME.   (BUILDING #7)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8292	15041-20000-03033	3921 W JEFFERSON BLVD	90016	10	120B185   822	5050028056	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.0257	-118.33897	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING. ADDING NEW LIGHTING NEW CONTROLS AND NEW PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2960.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8293	11041-20001-00573	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/11/2011 12:00:00 AM	ADDRESS	34.30363	-118.45814	add ground plate by inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8294	18041-20000-42039	4101 S REDWOOD AVE	90066	11	108B153   929	4230006233	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM	ADDRESS	33.99086	-118.44043	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.permit fees paid under application number 18041-90000-39529	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8295	15041-10000-43604	1746 S LA CIENEGA BLVD	90035	10	129B173  1522	5066006032	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.0458	-118.37629	PC FOR ENERGY. TI FOR A NEW STARBUCKS CAFEE (PREVIOUSLY BURGER KING) . TOTAL AREA 2910 SQ FT.B# 15016-10000-28309	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8296	17041-20000-12879	1520 W JAMES M. WOOD BLVD System A	90015	1	130-5A205 328	5137004029	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			Verifications in Progress	05/18/2017 12:00:00 AM	ADDRESS	34.05009	-118.27201	pv2install roof mounted pv system sized 18kw interconnected with msp.This is system A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8297	18041-20000-06749	7308 N COLDWATER CANYON AVE	91605	2	186B161   562	2324005032	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.20344	-118.41361	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8298	18041-20000-48731	17015 W RAYEN ST	91325	12	195B133   203	2690008018	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.23225	-118.50329	pv1install roof mounted pv system sized 13.65KW with 42 PV Modules and 2 inverters(5.0kW and 7.6kW) interconnected with msp.Fess $22.29 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8299	15041-10000-29087	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	11/05/2015 12:00:00 AM	ADDRESS	34.04797	-118.25815	FULL PLAN CHECK FOR TENANT IMPROVEMENT; SCOPE INCLUDES ELECTRICAL WORK WITH NEW EQUIPMENT AND LIGHTING FROM LEVELS BASEMENT  THRU 2ND FL;  PLAN CHECK ONLY - PERMIT WAS PREVIOUSLY OBTAINED UNDER 14041-10000-09802 IN CONJUNCTION WITH APPROVED PLANS STAMPED BY PREVIOUS ENGINEER HIRED FOR PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8300	13041-10000-34522	2595 N BEACHWOOD DR	90068	4	154-5A189 271	5585007021	RD2-1XL	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.11775	-118.32178	PV1, Install a 1.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[POWER-ONE # AURORA PV1-3.0-OUTD-S-US] and (6) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8301	16041-10000-30335	9415 S CENTRAL AVE	90002	9	094-5A209 446	6049030004	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	33.95094	-118.25488	PC for energy only to a new 2 story office building. Core and shell for entire 2nd floor. New lighting and power. New service is rated at 400 amps 120/240V 1phase 3wire. Total sqft = 4711.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8302	18041-20000-16571	416 N FAIRFAX AVE	90036	5	141B177  1410	5527030019	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.07873	-118.36128	Plan check for Title 24 only in existing space retail T.I. Total area: 1,391 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8303	18041-20002-00327	7453 N VANALDEN AVE	91335	3	186B121   462	2104020015	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM			PC Approved	07/09/2018 12:00:00 AM	ADDRESS	34.2063	-118.54929	Revisions to approved set.  Addition of ATS to system design for transfer of power from utility to ESS for back-up panel.  (((ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.9KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8304	18041-20000-37616	1619 N SAN REMO DR	90272	11	132B133    58	4425034016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.06071	-118.49995	THIS IS PLAN CHECK ONLY FOR POWER ON A NEW SINGLE FAMILY DWELLING WITH ATTACHED GARAGE AND BASEMENT. NEW 800A 120/240V, 1PH, 3W SERVICE, (8) PANELBOARDS, (1) 20kVA STANDBY GENERATOR. ** This is plan check only, electrical permit is issued under Building Combo Permit # 17010-30000-05187**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8305	13041-10003-04211	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			06/29/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM	ADDRESS	34.06209	-118.34912	Revisions to permitted set of plans: feeders to apartments disttribution boards are resized as original approved plans had  them oversized. Changes are clouded  ((((((((Plan check power and energy for 125 residential units and 50 joint/live work units apartment building over three level basement parking garage. 5000A service supplying building. Modification to separate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8306	14041-20000-12731	5337 E NAVARRO ST	90032	14	144A237   242	5219006019	RD2-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.08803	-118.16589	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER. 2 STRINGS. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8307	13041-10001-36109	8532 N THUNDERBIRD DR	91343	6	192B145   727	2654020***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.22559	-118.46904	Plan check only. inverter to be protected by bollards. Changed 125ABUS TO 200ABUS (pulled under separate permit). INVERTER MOVED TO GARAGE. Contractor information updated from 942329 to 990049. Transformerless system per applicant. CHANGES TO APPROVED: Back to plan check per inspector request for asbuilt grounded type system compared to transformerless in the original plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8308	17041-20000-09332	5208 N LEMONA AVE	91411	4	172-5A147 495	2250021034	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			03/23/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.16517	-118.45944	T-24 energy plan check for low rise residential per applicant request.  total square footage 3975.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8309	10041-20000-17753	3278 N CAHUENGA BLVD WEST	90068	4	159B181   575	2429009002	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Expired	12/05/2012 12:00:00 AM	ADDRESS	34.13011	-118.34934	Plan check T-24 Energy (general/emergency) lighting for TI of convience market. Permt for new 400A electrical system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8310	15041-10001-04221	9561 W SAWYER ST	90034	5	129B165   969	4309011019	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2015 12:00:00 AM			PC Approved	05/01/2015 12:00:00 AM	PIN	34.04581799	-118.39741157	Expedite per applicant request(((((Plan check for Solar roof mounted with system size: 24kW, 4 inverters and 78 modules and 4 combiner boxes. Take in plan per (F.Y.)()))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8311	15041-10000-04460	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM			PC Info Complete	02/24/2015 12:00:00 AM	ADDRESS	34.15886	-118.50032	Title 24 plan check only.  Total area = 10,759 sq. ft.T.I. to existing highrise office space including new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8312	13041-20000-27430	13031 W JEFFERSON BLVD Suite 600	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	12/24/2013 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	TI to an existing office building.  New panels, loads, lighting.  Load is greater thank 400 amps.  FULL PLAN CHECK.  Permit fees are $30,428.13	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8313	14041-20003-11429	6615 N ALLOTT AVE	91401	2	180B157   403	2329009038	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM			PC Approved	07/01/2014 12:00:00 AM	ADDRESS	34.19075	-118.42822	"Changes from previously approved plans. Addition of PV disconnect in front of house (in front of gate).Fee is $0.00 due to 2012 State Senate Bill 1222.[[[Changes from previously approved plans.  Relocate 4 modules on the roof.  No changes in module and inverter model number.  Note: All permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****"" 0 permit fee due to solar ordniance ""PV1.  Install 11.00 kW roof-mounted PV system, interconnect with main service panel.  (44) modules.  (2) transformerless inverters: SolarEdge SE5000A-US]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8314	17041-20000-30118	13951 W ENADIA WAY	91405	2	183B153   197	2216006008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.2004	-118.43747	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (43) modules, (1) load center, and (2) Tesla Powerwalls."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8315	14041-10000-16900	1621 W 265TH ST	90710	15	030B193    47	7411026024	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	33.78131	-118.3057	PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U(30) MODULES: TRINA SOLAR TSM-255PA05.18	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8316	19041-20000-42555	6300 N CANOGA AVE	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.18492	-118.59722	TENANT IMPROVEMENT ADD NEW LIGHTS PLAN CHECK FOR TITLE-24 ONLY TOTAL AFFECTED AREA 2260 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8317	13041-10011-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	09/07/16Changes to an approved set of plans. All changes are made under delta 43. Scope includes upgrading the 2 sump pumps from 2HP to 5HP and revising the conductor sizes for the sump pumps. ((((((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8318	17041-10000-17451	10311 S LA CIENEGA BLVD	90045	11	090B173   271	4129031001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM			Reviewed by Supervisor	06/13/2017 12:00:00 AM	ADDRESS	33.94269	-118.37026	CHANGE OF USE TO WAREHOUSE. PROVIDING NEW LIGHTING AND EQUIPMENT. REUSING EXISTING SERVICE AND PROVIDING NEW SERVICE 400A. TOTAL NEW CONNNECTED LOAD GREATER THAN 400A. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8319	19041-10000-16901	9035 N INDEPENDENCE AVE	91311										Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	06/10/2019 12:00:00 AM				"Plan check FOR  PV ""FIT"" ON COMMERCIAL ROOF TOP PV INSTALLATION. PV SYSTEM  RATED AT 99.9kw AC / KW 115kw DC PV2 roofmounted system with (1) inverter, (297) modules, (149) optimizer interconnecting through the main service panel.) CONNECTED TO 200A 277/480 NEW SERVICE. SERVICE EQUIPMENT UNDER EXPRESS PERMIT."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8320	16041-20000-04948	16900 W SUPERIOR ST	91343	12	201B133   418	2686016019	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Refund in Progress	01/05/2017 12:00:00 AM	ADDRESS	34.24694	-118.50026	Plan check for a PV1 roof-mounted PV system. System size is 9.2 kWac and consists of (2) inverters, (45) modules, (1) combiner box, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8321	16041-10000-43761	1251 S GRAND AVE	90015	14	126A207   160	5139022018	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.03927	-118.26451	Plan check for powr and erengy 1st time tenant Starbucks in a mixuse building 115 units appartment. Total area: 1930 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8322	14041-10001-08145	12665 W VILLAGE LANE block 5	90094	11	102B161  1257	4211034036	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/17/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	33.97786	-118.41484	Revision to the approve set of plan. Adding less than 10 devices and removing some.<<FA FOR PLAYA VISTA II BLOCK 5. 4 buildings but only 1 FACP. Fee arrangment to be verified by plan checker.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8323	19041-10000-36920	1344 N HOBART BLVD	90027	13	147A195   224	5544035025	R3-1XL	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.09631	-118.30545	PC FOR FA SYSTEM FOR AN APARTMENT (1) FACP AND (517) DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8324	15041-10000-15641	16139 W STAGG ST	91406	2	189B137    61	2205004035		South Valley				1275.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	PIN	34.21335038	-118.48579871	Retrofit of existing lights to LED fixtures.  Title 24 Part 6 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8325	10041-10000-21516	5788 W MELROSE AVE	90004	4	141B189   392	5523010020	C2-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM			PC Info Complete	04/06/2011 12:00:00 AM	PIN	34.0832443	-118.32629749	INSTALL A SOIL VAPOR EXTRACTION SYSTEM IN A COMMERCIAL AREA - CLASS I DIV II.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8326	19041-20000-17177	555 W 5TH ST 38TH FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	PLAN CHECK FOR T24 ONLY. LIGHTS AND OUTLETS ONLY FOR TI RENOVATION OF THE 38TH FLOOR OF A EXISTING HIGH RISE. TOTAL SQUARE FOOTAGE = 18,264SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8327	19041-10000-04641	8522 S LINCOLN BLVD	90045	11	096B157   612	4113014001	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	33.96005	-118.41924	INTERIOR TENANT IMPROVEMENT OF EXISTING RESTAURANT/BARNEW FINISHES, RESTROOMS, LIGHTING AND MECHANICAL DISTRIBUTION THROUGHOUT. PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8328	12041-10000-08075	215 E 5TH ST	90013	9	129A213   371	5148010026	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.04582	-118.24698	New service, switchboard, panels, circuits, loads, lighting for an existing commercial building.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8329	14041-10001-07372	8511 W BEVERLY PL	90048	5	138B173   350	4337012040	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Public Safety Only			01/05/2015 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.07669	-118.37705	NEW FIRE ALARM SYSTEM FOR A SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8330	18041-20000-16572	6933 W SANTA MONICA BLVD	90038	4	144B181   438	5532017020	C2-1D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	01/11/2021 12:00:00 AM		Permit Finaled	02/15/2024 12:00:00 AM	PIN	34.09088016	-118.34077767	4000A 480Y/277V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8331	14041-10000-07772	1734 N SUNNY HEIGHTS DR	90065	1	150A221   106	5464010047	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.10613	-118.21973	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED STANDARD SOLAR ARAY ON A TWO STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PVI-3.0-OUTD-S-US-Z-A(14) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8332	18041-20002-38699	3418 E 3RD ST	90063	14	124-5A227 317	5179013026	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2039.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Issued	03/06/2019 12:00:00 AM	ADDRESS	34.03452	-118.19579	$0 plan check fee due to department errorchange in work description, addition of 5KW LG CHEM RESU ESS*original*pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8333	16041-20000-23613	16411 W OTSEGO ST	91436	5	171B137   250	2260002009	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.16274	-118.49015	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (41) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8334	13041-20000-03643	16500 W VENTURA BLVD	91436	5	168B137   382	2284005036	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Closed	04/29/2014 12:00:00 AM	ADDRESS	34.15743	-118.49262	Change of use, new Dental office.  Full plan check.  Existing 4-story commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8335	15041-20000-03319	11111 N BECKFORD AVE	91326	12	210B121   294	2718003011	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.27217	-118.54893	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.3KW INTERCONNECTED WITH MSP.(25) E20-327NE SUNPOWER MODULES(2) SPR INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8336	19041-20000-53025	16120 W HARTSOOK ST	91436	5	171B141   162	2260019017	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	02/01/2020 12:00:00 AM	ADDRESS	34.16395	-118.48437	PV1. INSTALL 14.19 KW DC ROOFMOUNTED PV SYSTEM WITH (43) MODULES, OPTIMIZERS AND (1) INVERTER(SE11400).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8337	17041-20000-19185	5670 W WILSHIRE BLVD ste 2200	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8338	16041-20000-44238	2856 E PICO BLVD	90023	14	118-5A221  54	5169017006	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.01917	-118.21888	remove existing hid fixtures and replace with new led outdoor.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8339	13041-20000-03383	1859 W BLAKE AVE	90039	13	147A213    71	5442008034	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.09824	-118.2434	T-24 lighting plan check for remodeled space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8340	14041-20000-09877	735 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR ZARA STORAGE. 6235 SQFT, EMERGENCY LIGHITNG EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8341	12041-10000-09812	4600 W COLORADO BLVD	90039	13	162B205   273	5593018903	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	34.14094	-118.27314	3 new 1,500 HP blowers at the LADWP water reclamation plant at 4,000Volts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8342	11041-20000-27444	23033 W MOSBY ST	91364	3	168B097   712	2074035010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2011 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	ADDRESS	34.15354	-118.62671	Install roof mounted enphase inverters on roof on single family dwelling, and new subpanel for solar voltaic system, the residential service was upgraded to 200 amperes.  A variance to install enphase inverter model M215 was submitted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8343	11041-10000-00371	20140 W SHERMAN WAY BLDG C	91306	3	183B113    63	2135038015	(T)(Q)C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	34.20085	-118.57213	New self storage building C.  Electrical plan check is for power and energy. Electrical approval should be hold until the building permit be issued.  The permit for switchboard MSB is issued as part of the buidling C permit, and MSB will supply also building A, B, and theVerizon structure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8344	17041-10001-03298	5126 W WILSHIRE BLVD	90036	4	132B181    36	5507026022	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.06197	-118.34164	PC for changes to approved set(T24 only) - changes in lighting and receptacles in office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8345	17041-10000-35062	2135 N IVAR AVE 1-9	90068	4	151-5A187 246	5576017043	RD2-1XL	Central	Hollywood	Hollywood United	Yes	1896.00	Electrical	Electrical	Apartment			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.10924	-118.32746	Install New rooftop solar on a unit in the apartment building.  4.14 kWAC system, (18) modules with (18) microinverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8346	19041-20000-25338	3470 S TROUSDALE PKWY	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.02202	-118.28393	T24 PLAN CHECK FOR EXISITNG CLASSROOM TI. LIGHTS AND OUTLETS ONLY. REPLACING 2X4 LIGHTS WITH 2X2. TOTAL SQUARE FOOTAGE = 1085 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8347	17041-10000-10934	2029 S CENTURY PARK EAST STE  1750	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to suite 1750 of existing commercial office highrise.  New lighting and receptacles.  Total area = 11,160 sq. ft.     Building permit #17016-30000-03548	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8348	18041-10000-41028	119 N HOBART BLVD	90004	10	138B193   841	5517011033	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07435	-118.30564	Install New Rooftop PV system, 7.2 kW AC / 9kW DC. Install (30) modules and (30) IQ7 enphase micro inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8349	19041-10000-41930	1100 S SAN PEDRO ST A-9a &-A-9b	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Info Complete	10/15/2019 12:00:00 AM	ADDRESS	34.03515	-118.25194	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS DIVIDING AN EXISTING RETAIL SPACE INTO TWO RETAIL SPACES. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND EQUIPMENT. TOTAL AFFECTED AREA IS 2726 SQFT. B#: 19014-10000-03022	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8350	10041-10000-24837	523 W 6TH ST #1234	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	12/28/2011 12:00:00 AM	PIN	34.04872199	-118.25441618	Remodel suit 1234.  T-24 and emergency lighting plan check.  Inspector verify if any emergency lighting required in confrence room 1219, verify that occupancy sensors are multi-level type, and verify that luminaires type F1 and F1E are Program Start type.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8351	14041-10000-30013	837 S SPRING ST	90014	14	127-5A209 216	5144016053	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Closed	12/11/2015 12:00:00 AM	ADDRESS	34.04229	-118.25463	Plan check for power and title 24.  Installation of new house panel, lighting, and (3) tenant panels for a core and shell project.  Existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8352	13041-10000-17524	3356 S MCLAUGHLIN AVE	90066	11	117B153   461	4249006024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.01779	-118.4325	PV1 9.468KW XFRMLESS. 1 STORY. NONSTD. ROOFMOUNT.  [ (1)  INV: powerone PVI-4.2-OUT-S-US ] [ (18) MOD: WINAICO wsp-260m6 ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8353	11041-10001-02957	1132 N VERMONT AVE	90029	13	144B197   506	5542029039	C2-1D, C2-2, P-1	Central	Hollywood	East Hollywood	YES	1913.01	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.09184	-118.29154	SUPPL.  PLAN CHECK  FOR CHANGES TO APPROVED PLANS.  RELOCATE THE UTILITY TRANSFORMER AND THE SERVICE EQUIPMENT.  <<<<<< SERVICE UPGRADE TO 1200AMP & ADD NEW LOAD.>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8354	13041-20001-25512	13031 W JEFFERSON BLVD Suite #800	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			PC Info Complete	03/26/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	Change from previously approved plans.  Changes include add one panel and relocate branch circuits.  Plan check for power only.  All changes are clouded on plans.Previous Description:RENOVATION OF OFFICES. NEW CONNECTED LOAD GREATER THEN 400A. FULL PC FOR POWER AND ENERGY. COLLECTION OF FEES 93%, CHARGE REST ON FINAL (42 BRANCH CIRCUITS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8355	19041-30000-38928	4103 S WESTERN AVE	90062	8	114B193   543	5021031028	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.0097	-118.30917	energy plan check only for T.I. of (e) bank to including addition of unisex restroom. area of scope 100sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8356	17041-30000-25508	801 S FIGUEROA ST 3rd Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area 12,325 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8357	12041-10000-31007	8701 S LINCOLN BLVD	90045	11	096B161   737	4119026038	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	33.95847	-118.41793	Fees under submittal 2 for significant design changes: addition of new service and switchboards and panels.T.I.  Existing Ralph's Supermarket.  Remodel of the entire store.  New lighting, panels, ckts, etc.  Fullplan check for power and energy. Generator tower installed for future mobile generator connection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8358	18041-10000-25161	18422 W VANOWEN ST	91335	3	180B125    18	2125014033	[Q]C2-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Issued	07/06/2018 12:00:00 AM	ADDRESS	34.19372	-118.53442	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8359	17041-20000-19339	221 N FIGUEROA ST 10TH FLR	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for energy only. TI to existing office on 10th floor of high rise building. New lighting (incl. emergency) - 17,722sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8360	15041-20000-38561	15239 W ROXFORD ST	91342	7	228B145   835	2501016057	(T)(Q)RD6-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.31783	-118.46473	PV1.  Install 2.65 kW roof-mounted, utility-interactive PV system - (10) Kyocera KU2656ZPA modules and (1) ABB PVI-3.0 transformerless inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8361	15041-10000-15798	5196 E ALHAMBRA AVE	90032	14	138A235    97	5216022010	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	34.07337	-118.17238	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1179.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8362	17041-20001-43984	14810 W WEDDINGTON ST	91411	4	172-5A149 173	2249022010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.16654	-118.45574	expeditepv1install roof mounted pv system sized 9kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8363	18041-20000-14381	14200 W MULHOLLAND DR	90077	5	159B153   229	4379032011	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.13029	-118.44235	pv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8364	19041-30000-39683	700 S FLOWER ST 15TH FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Issued	10/01/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLAN CHECK FOR T-24 ENERGY ONLY, TENANT IMPROVEMENT TO OFFICE SPACE FOR ELEVATOR LOBBY FINISHES AND NEW RESTROOMS FIXTURES. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1158	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8365	13041-10000-24238	1800 N RISING GLEN ROAD	90069	4	150B169  1331	5561023040	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.10398	-118.38278	PV1. ROOF MOUNTED PHOTOVOLTAIC SYSTEM. 13.08 KW DC SYSTEM SIZE.  40 SPR-327 MODULES. 2 PV1 6000 INVERTER. UNGROUNDED SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8366	14041-20000-13777	15523 W LEMAC ST	91406	6	189B145   596	2222004007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Expired	07/14/2016 12:00:00 AM	ADDRESS	34.21146	-118.47129	(($0 permit fee due to senate bill 1222 from 2012)))13KW PV1 roof-mounted system with (52) Canadian Solar CS6P-250PX modules with optimizers and (2) Solaredge SE6000A-US-ZB-U transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8367	17041-10000-17712	1601 N VINE ST 7TH FLR	90028	13	148-5A187 301	5546009154	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.09996	-118.32693	PC FOR  INTERIOR OFFICE TI FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD LESS THAN 400A.WORK 7TH FLOOR  FULL FLOOR  TOTAL AFFECTED AREA 13,397 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8368	13041-10006-32351	1026 S BROADWAY BLDG A	90015	14	126A209   140	5139014006	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			01/09/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	ADDRESS	34.04029	-118.25788	Changes to approved set. Per DWP requierments due to SPD device ( DWP bulletin #1 10/4/2016)Adding a disconnecting mean on fire pump feeder in  compliance with 695.4 (B)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8369	19041-10001-07769	5500 W JEFFERSON BLVD	90016	10	120B173  1730	5047015033	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Issued	10/16/2019 12:00:00 AM	ADDRESS	34.02557	-118.3665	DELTA 1 CHANGES TO AN APPROVED SET. CHANGES TO THE TYPES OF FIXTURES IN OFFICE SPACE, CHANGES TO THE RECEPTACLES LAYOUT AND EQUIPMENT LOCATIONS. ALL LOADS AND NEW CIRCUITS ARE UPDATED ON THE PANEL SCHEDULE. T-24 UPDATED TO MATCH CHANGES.   ((FULL PLAN CHECK FOR A FIRST TIME TENANT IN AN OFFICE SPACE. PARTIAL SPACE OF THE FLOOR WAS PERMITTED UNDER A SEPERATE PERMIT. SCOPE INCLUDES 3 NEW PANELS, EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 7834 SQ.FTB#19016-10001-02605	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8370	13041-20000-21029	16800 W LABRADOR ST	91343	12	201B137   288	2686001024	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.24918	-118.49823	PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 7.848KW. 24 MODULES AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8371	13041-20000-09812	1677 S HARVARD BLVD	90006	10	126B193   396	5074021020	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2013 12:00:00 AM			PC Info Complete	06/17/2013 12:00:00 AM	ADDRESS	34.04285	-118.30449	"5.20 kw roof mounted photovoltaic system using enphase microinverters.  Single family residence.      ""COMPLY WITH DEPARTMENT ORDER effective date08/26/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8372	19041-20000-28675	7946 N ETHEL AVE pv1	91605	2	189B161   465	2303018052	(T)R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.21527	-118.41607	pv1install roof mounted pv system sized 11.2KW DC/9.52 KW AC interconnected with msp. scope of work consists of (35) pv modules with microinverters and a combiner	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8373	14041-20000-19572	17149 W LISETTE ST	91344	12	222B133   480	2602015007	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.30289	-118.50638	3.87KW PV1 roof-mounted microinverter system, including (18) Sunmodule Plus SW275 Mono modules and Enphase M215 Microinverters connecting through a 60 Amp bus PV load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8374	14041-20000-00686	6430 W SUNSET BLVD SUITE 450	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 450	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8375	16041-20001-44981	7183 WORLD WAY WEST	90045	11	090B157   100	4117032900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	33.94557	-118.41975	changes to an approved set of plans.  changes noted delta 1.  Portable crusher plant at LAX for temporary construction.  (1) power trailer, (1) 800amp mcc and (1) 600amp mcc.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8376	11041-10000-25970	23710 W KIVIK ST	91367	3	171B093   380	2047004006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.16542	-118.64252	Roof mounted PV system, 7 KW, for a single-family dwelling including upgrade of main service to 200A..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8377	19041-20000-49528	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.27548	-118.56626	PLAN CHECK FOR ADDITION OF ONLY EM EGRESS LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8378	10041-20000-25381	18411 W VICTORY BLVD	91335	3	180B125   625	2124001902	OS-1XL	South Valley	Reseda - West Van Nuys	Reseda		1329.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Info Complete	12/22/2010 12:00:00 AM	ADDRESS	34.18676	-118.53453	outdoor lighting swimming pool area	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8379	13041-20000-14495	16644 W DEMARET PL	91344	12	216B137    98	2609010002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.29105	-118.49525	New ungrounded PV system for an existing sfr.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8380	13041-10000-33304	925 W WEST 34TH ST DEN-1&2FL	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.0239	-118.28647	permit to be pulled at EPC counter only. PC for energy only. TI TO MECHANICAL ROOM 5. EQUIPMENT REPLACEMENT. Less than 400A. emergency provided from generator. Located in USC's Eileend and Kenneth T. Norris Dental Science Center (DEN). TI TO M/F RESTROOMS (1ST+2ND FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8381	17041-10001-28236	369 N SUMAC LANE	90402	11	123B129   446	4410024028	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	ADDRESS	34.03339	-118.51374	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8382	16041-10000-36128	2049 S CENTURY PARK EAST 600	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	OFFICE TI. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8383	12041-10000-18251	3967 N FREDONIA DR	90068	4	159B177    71	2380002012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.13558	-118.36551	Plan check for new roof mounted 5.4KW photovoltaic system (using SolarEdge transformerless inverter). Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8384	17041-10000-19452	24002 S FRAMPTON AVE	90710	15	042B193   751	7439009019	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.80689	-118.30083	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8385	15041-10000-39928	111 E UNIVERSAL HOLLYWOOD DR 33RD FL	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	T24 OLNLY. T.I FOR A HIGH RISE BUILDING . TOTAL AREA 19233 SQ FT. 33TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8386	15041-10000-13391	1726 N NORTH SPRING ST Unit 2	90012	1	136-5A219  47	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM			PC Info Complete	04/28/2016 12:00:00 AM	ADDRESS	34.06983	-118.2261	CHANGE OF USE FROM EXISTING WAREHOUSE TO OFFICE.  PLAN CHECK FOR ENERGY ONLY. TOTAL AFFECTED AREA IS 5790 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8387	17041-10000-05342	919 S ALBANY ST	90015	1	129A205    54	5137006025	C2-1	Central	Westlake			2100.00	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Issued	03/07/2017 12:00:00 AM	ADDRESS	34.04913	-118.27045	PLAN CHECK FOR NEW 3-STORY TRIAL ADVOCACY CENTER (SCHOOL BLDG)FIRE ALARM SYSTEM CONSISTING OF 84 DEVICES AND 1 FIRE ALARM PANEL, AND 1 STROBE POWER PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8388	19041-20000-22179	22135 W ROSCOE BLVD LOT #17	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 17.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8389	12041-10000-27648	415 S LA BREA AVE	90036	4	135B181   536	5508006028	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.06635	-118.34436	T24 PLANS WERE ADDED TO OTHER SET OF PLANS 11/28/12Construct 1-level retail below roof top parking deck.  New service, panels, circuits, outdoor and indoor lighting. EPC is for power and energy. (T24 calc. not included @ the submittal, applicant will bring it later)SHELL ONLY; EXCEPT FOR ELEVATORS AND HOUSE PNEL, CONDUITS FOR FUTURE TENANT SPACES ARE STUB-UP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8390	19041-10000-51044	3263 N FLETCHER DR	90065	13	154-5A213 131	5458017019	[Q]C1-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	06/03/2020 12:00:00 AM		Permit Finaled	01/04/2023 12:00:00 AM	ADDRESS	34.11766	-118.2422	PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW CIRCUITS, LIGHTHING, AND CONTROLS. TOTAL AFFECTED AREA  IS  921 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8391	18041-10000-23937	106 N WEST CHANNEL ROAD	90402	11	120B129   105	4410010020	[Q]C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.02833	-118.51897	TI TO (E) RESTAURANT. T-24 ENERGY ONLY. BLDG PERMIT: 17016-20000-04546	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8392	11041-20000-13123	6621 N VAN NUYS BLVD	91405	6	180B149   351	2236010006	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02, 1281.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.19136	-118.44902	fire alarm system addition to existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8393	15041-20000-30833	6301 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.18467	-118.60176	TENANT IMPROVEMENT FOR A (N) KITCHEN & SERVERY.  pc for power and energy. part of total ti package.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8394	15041-20000-35387	3643 S EMPIRE DR 1-8	90034	5	120B165   769	4313003009	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			10/22/2015 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	08/08/2021 12:00:00 AM	ADDRESS	34.02527	-118.40381	New 8 unit apartement build. 5 story living spaces + 1 level subterannian. 600 A main service, total area: 11,830 sq. ft. Fire Alarm will be submitted at a later time. Full PC for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8395	19041-10000-41735	707 W WILSHIRE BLVD	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	02/13/2020 12:00:00 AM		Permit Finaled	05/19/2021 12:00:00 AM	ADDRESS	34.04893	-118.2572	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI IN AN EXISTING COMMERCIAL SPACE (BANK VAULT TO GYM). SCOPE OF WORK INCLUDES NEW LIGHTGING, CONTROLS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 8984 SQFT. NOTE FULL PLAN CHECK MAY BE REQUIRED PER INSPECTORS REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8396	14041-10002-30882	849 W 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	PIN	34.02383917	-118.28572873	Revision to approved set per inspector's field correction. Changes noted under Delta-1, Delta-2, Delta-3, Delta-4, Delta-5, Delta-7(xfrmr breaker size, additional circuits, revise breaker size to some motor loads - Refer to single line diagram)*4/18/16: Additional PC, removed AHU-01<<New 2-story with mezzanine Dance Center building for assembly and classrooms.  PDPP  50% submittal for zoning, disabled access, green, partial fire life safety (no structural)...	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8397	16041-10002-14569	1616 W 209TH ST #2	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO MAIN BREAKER RATING TO 60A MAIN. NO OTHER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8398	18041-10000-05940	1046 N GALLOWAY ST	90272	11	129B129   524	4423012030	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.04866	-118.52129	PC for PV solar for 10kW(ac) rooftop system. Installing 32 modules 10.4kW(DC) with optimizer and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8399	18041-20001-32263	107 N DELFERN DR	90077	5	141B157   130	4358005006	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	34.08012	-118.42866	Revision to approved plan.  Change of interconnection detail from single-phase to three-phase service.$0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8400	19041-20000-07353	5225 N BLAKESLEE AVE	91601	2	171B173   535	2350018084	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	10/03/2020 12:00:00 AM	ADDRESS	34.16534	-118.37263	PV2.  Install 258.42 kW DC / 236.13 kW AC roof mounted grid tied PV system installed on (E) 5-story apartment building.  (708) modules with (8) 30 kW rated string inverters, 500 kVA transformer, and 400A PV load center. $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8401	18041-10000-44465	7817 N HASKELL AVE	91406	6	189B141   205	2206002031	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.2127	-118.47511	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8402	16041-10001-20319	2256 S BARRY AVE	90064	11	123B153   413	4260014035	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Issued	10/27/2016 12:00:00 AM	ADDRESS	34.03353	-118.44564	PC FOR BUILD OUT OF SUITE 2B.  THIS IS IN ADDITION TO ORIGINAL SCOPE OF WORK WHICH IS HOUSE AND 2A. THIS IS PLAN CHECK AND PERMIT FOR ADDITIONAL SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8403	13041-10001-17362	729 W 28TH ST	90007	9	121-5A203  48	5123016402	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.02755	-118.28038	PLAN CHECK ONLY. REVISION TO APPROVED PLANS FOR CHANGES TO INCLUDE EMERGERNCY LIGHTING.  EXISTING TYPE R2 OCCUPANCY (RESIDENTIAL ) 2- STORY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8404	17041-20002-39319	1545 S FAIRFAX AVE	90019	10	129B173   994	5068021007	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			06/14/2019 12:00:00 AM			PC Approved	06/14/2019 12:00:00 AM	ADDRESS	34.04831	-118.36762	6/14/2019changes to an approved set of plans. changes to phase converter and feeder length, (150/2G).  this is plan check only.  ((((New 4-story 10-unit apartment building over one level subterranean garage.  600 A 120/240V 1ph-3w service.  Plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8405	15041-10001-25019	3120 W LACLEDE AVE	90039	13	153B209  1050	5436010004	[Q]RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.11258	-118.24972	((EXPEDITE FEES))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. 7.8KW SYSTEM. 28 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8406	13041-10000-32267	14016 W ROSCOE BLVD	91402	6	192B153   799	2213001017	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			Reviewed by Supervisor	11/26/2013 12:00:00 AM	ADDRESS	34.22147	-118.43831	PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 16 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8407	14041-20000-23482	17410 W LAHEY ST	91344	12	210B129   276	2711011021	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.27314	-118.51331	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.STANDARD PLAN CENTRAL TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8408	14041-10000-29856	124 S CROFT AVE	90048	5	138B173   687	5511014007	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			10/28/2014 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	12/18/2022 12:00:00 AM	ADDRESS	34.07387	-118.37406	Methange gas control system for a new 5 story apartment building.  14devices + 1 control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8409	19041-10000-25437	375 S COLUMBIA AVE	90017	1	132A207    44	5153019020	R4-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.05754	-118.26579	Power plan check per applicant request for an existing 1200-amp service located in 5-story hotel. Scope includes adding 65-AC unit for the whole building.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8410	09041-20001-22007	440 S VERMONT AVE	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	01/28/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Delta 1, 2, 3, 4 modifications to the approved set of plans.  The original permit will be used for most of the inspection.  A supplemental permit will be issued only for the new equipment not covered by the original permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8411	15041-20000-05280	6316 N TOPANGA CANYON BLVD #1140-Building B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	"Plan check for power and energy. First time tenant in 2-story retail building (""Jonathan Adler"") part of Westfield Village. Building B. 6,747sqft."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8412	12041-10000-22857	12381 W OSBORNE ST	91331	7	207B165   230	2536015029	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Apartment			09/25/2012 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.26101	-118.40283	New 27 unit apartment, 3 story with subterranean parking. EPC is for power and energy. (fire alarm variance was paied)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8413	17041-10000-39700	1223 S WELLESLEY AVE	90025	11	126B145   451	4267036009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			11/02/2017 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	34.0421	-118.46871	PLAN CEHCK FOR POWER AND ENERGY, NEW A 4 STORY 10 UNIT APPARTMENT BUILDING 7,944 SF SUB-TERRANEAN GARAGE. 800A SERVICE, 120/240V 3PHASE, 4W SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8414	17041-10000-01449	154 W AVENUE 27	90031	1	141A221   298	5205020027	R1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.07881	-118.21698	PV, INSTALL 3.51 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(13) MODULES: HANWHA 270(13) MICROINVETERS: ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8415	19041-10000-07465	3321 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	09/21/2021 12:00:00 AM	ADDRESS	34.0275	-118.3723	$0 fee due to AB1414.PV2. New Rooftop solar system. System size 590.24kW DC / 523.01 KW AC . Install:(1736) modules(4) 100 kW AC central inverters(3) 33.3kW AC central inverters(868) optimizers(1) 800A subpanel 277/480V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8416	19041-10000-02858	400 N PINTORESCA DR	90272	11	126B121   238	4414019007	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM			Verifications in Progress	02/07/2019 12:00:00 AM	ADDRESS	34.04349	-118.54255	PLAN CHECK FOR TWO 13.5KWH  BATTERIES(TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. NO PV SYSTEM. SCOPE INCLUDES NEW LOAD CENTER 125A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8417	11041-10004-16708	149 N WESTERN AVE	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.07443	-118.30931	NEW 800A SERVICE AND CIRCUITS FOR A GROUP OF 6 COMMERCIAL BUILDINGS.  MAIN SERVICE IS IN BUILDING 4558 W. COUNCIL ST.  OTHER BUILDINGS (4556 W. COUNCIL AVE.,     143 N. WESTERN AVE,      147 N. WESTERN AVE,    151 N. WESTERN AVE.) WILL BE ON SUPPLEMENTAL PERMITS TO THIS.     THIS APPLICATION IS FOR 149 N. WESTERN AVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8418	13041-20000-34152	4222 N WOODCLIFF ROAD	91403	4	165A145    99	2281003005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.14725	-118.46722	Rooftop PV system for an existing single family residence.  System is UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8419	19041-10000-08976	10302 W VENICE BLVD	90232	5	117B165    21	4208005038	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	PIN	34.02078391	-118.40268239	T-24 plan check for a Tenant Improvement to existing restaurant. Scope includes new lighting and receptacles. Total affected area is 200 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8420	15041-20002-37216	7118 W GREELEY ST	91042	7	202-5A201 372	2568014016	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.24888	-118.28667	07/11/2016 Changes to an approved set of plans. PV panel module power output has increased and the main service panel has been upgraded. All changes have been reflected onto the single line diagram.*****Previous Work Description*****[ 5/25/16 CHANGES TO APPROVED SET. MODULES REDUCED TO 17, INVERTER SIZE AND MODEL CHANGED TO 3.8KW AND PV BREAKER SIZE REDUCED TO 20 AMPS.]]]PV1, 5.00KW AC roof mounted system with (21) Q Pro BFR-G4 modules, and (1) Solaredge SE5000A inverter interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8421	19041-20000-12048	141 N ROBERTSON BLVD	90048	5	138B169   243	4334001017	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	05/26/2020 12:00:00 AM	ADDRESS	34.07639	-118.38389	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8422	18041-10000-14643	6589 W FOOTHILL BLVD	91042	7	201A203    68	2570019028	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.24648	-118.27566	PC FOR BANK TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA  18000  SQ.FT REPLACING EXISTING LIGHTS WITH UL LISTED RETROFIT LED KIT. EXISTING EMERGENCY LIGHTS AND SWITCHING TO REMAIN.INDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8423	17041-20000-08719	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.17705	-118.6144	PV2. GROUNDMOUNT SOLAR SYSTEM. SYSTEM SIZE: 70 KW. (223) WINAICO WSP 300 MODULES(3) SYMO 12.0 (3) SYMO 10.0See comments.....	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8424	15041-10000-40450	130 S LA BREA AVE 2ND FLOOR	90036	5	138B181  1004	5513018008	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	34.07262	-118.34383	T-24, TI TO THE SECOND FLOOR OF A RETAIL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4014	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8425	17041-20001-21346	8301 S DELGANY AVE	90293	11	096B153   691	4115003024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	33.9589	-118.44197	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.73 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8426	10041-10002-05583	700 N FAIRFAX AVE	90046	5	141B177   515	5527011005	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM			Corrections Issued	04/20/2011 12:00:00 AM	ADDRESS	34.0841	-118.36119	Revision to the approved plan. Change from Fully rated to series rating, change the size of feeder for panels A, B, C. Change the T24 calc. EPC is for delta 1 changes. (((((((((((((((((REVISION TO APPROVED PLANS. METHANE BUFFER ZONE.  EPC FOR POWER AND ENERGY OF ONE STORY RETAIL BUILDING I.  METHANE MITIGATION REPORT WAS PROVIDED. NEW SERVICE, PANELS, CKTS, & T24. ORIGINAL PLAN CHECK #08041-10000-07840(((((  CHANGE FUSES TO BREAKERS AND SERVICE FROM UNDER GROUND TO OVER HEAD NE CHANGES TO THE FAULT VALUE FULLY RATED.))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8427	10041-10001-01258	624 S GRAND AVE 4TH FLR	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM	04/21/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	PIN	34.04778206	-118.25563275	Plan check for new 600A & 400A SWBD, xfrmr, panels, feeders and relocating ckts for existing electrical system in high-rise building. Existing permit cover portion of the work #10041-10000-01258.  This plan is feed non required stand by sytem from an approved UPS system instead of stand by generators.  Supplemental  permit is required for this work	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8428	17041-20000-22204	7301 N MEDICAL CENTER DR #200	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.20262	-118.62963	Plan check for power and energy. TI to (E) Medical office. New lighting - 1,190sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8429	19041-20000-32920	6735 W SELMA AVE	90028	13	148-5A185 274	5547013001	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.09981	-118.33744	FACP replacement for existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8430	16041-20000-38089	23800 W LADRILLO ST	91367	3	171B093   649	2047012014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.16302	-118.6438	PV1.  Install 9.28 kW DC roof mounted grid-tied PV system.  (29) modules with (1) 7.6 kW-rated inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8431	13041-20000-25091	21650 W OXNARD ST 7th floor	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	New offices in an existing high-rise office building on the 7th floor.  DUE TO MULTIPLE PROJECTS ON FLOORS 6-10 BY THIS ENGINEER AND WORK BY OTHERS FULL PLAN CHECK FOR LOAD GREATER THAN 400 AMPS IS LIKELY TO BE REQUIRED SUBJECT TO FIELD INSPECITON.  Load is less than 400 amps per applicant for this portion.  PLAN Check Only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8432	16041-20000-10568	9041 W CATTARAUGUS AVE	90034	5	123B169   385	4301003032	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Issued	04/06/2016 12:00:00 AM	ADDRESS	34.03515	-118.39007	$0 permit fee due to Senate Bill SB1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8433	16041-10000-45773	380-384 WORLD WAY MSC-Utilidor	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for power and Title-24.  Provide normal and emergency power to utility tunnel and baggage handling system for LAX MSC building.Building permit #16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8434	13041-10000-09209	867 S WELLESLEY AVE	90049	11	129B141   624	4264017001	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.04583	-118.47528	PV1 SINGLE FAMILY DWELLING. 3.45 kW SOLAR ARRAY INSTALLATION. ENPHASE M215 MICROINVERTER. TOTAL MODULES: 16.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8435	13041-20001-31154	5949 N VAN NUYS BLVD	91411	4	177A151   145	2244001030	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	PIN	34.17890191	-118.44917219	((EXPEDITE FEES))<- Decided not to expeditePV2 (1) 500KW INVERTER 1284 MODULES AND 13 COMBINER BOXES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8436	14041-20000-07469	17649 W SAMMY LN	91325	12	201B129   472	2755010052	[T][Q]RD3-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	PIN	34.24887147	-118.51954914	Per application request, plan check for energy only.  Install lighting in recreation room.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8437	11041-20000-01609	601 W 5TH ST	90071	9	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.05049	-118.25386	Replace fire alarm control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8438	17041-30000-25136	4231 S MCLAUGHLIN AVE	90066	11	111B161   388	4233007006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Apartment			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.00074	-118.41863	Plan check for a fire alarm system for an apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (47) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8439	16041-10000-18094	12775 W MILLENNIUM ste 135	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.97584	-118.4171	BUS EXTENSION TO EXISTING SERVICE. 2500A SECTION. PERMIT FOR SECTION ONLY. NO LOADS AND NO OTHER CHANGES DONE AT THIS TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8440	17041-20000-03404	1999 S AVENUE OF THE STARS 37flr	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	ti to an existing commercial building (high rise).  providing new lighting new controls to existing panels.  This is for tenant spaces only (white boox) total square footage 5300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8441	19041-10000-23524	13502 W DELANO ST	91401	2	177B157   541	2330018007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.18198	-118.42713	Note: FEES ARE $0 DUE TO AB 1414(ePlan) PV1 PLAN CHECK FOR ROOF MOUNTED 10KW PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER  AND 46 MODULES WITH P320 OPTIMIZERS - - 13.8 kW system size (STC-DC) - -	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8442	17041-10000-35114	9100 S SEPULVEDA BLVD # 116	90045	11	093B165    26	4124001017	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	33.95437	-118.39596	PC for T24 only for new lighting. Intalling new panel, receptacles, lights and equipment. Total are of 2705sqft.B 17016-10000-25038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8443	16041-10000-41318	1900 S AVENUE OF THE STARS 3rd FL	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.05979	-118.41671	TENANT IMPROVEMENT TO (E) OFFICE, 3RF FLR 2189 SF, CONSTRUCT NEW NON-BEARING PARTITIONS, CEILING, AND FINISHES.  NEW ACCESSIBLE MEN'S AND WOMEN'S RESTROOMS, ELEVATOR LOBBY, 1-HOUR CORRIDOR, AND COMMON AREA UPGRADES. REPLACE NEW FIRE RATED DOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8444	17041-20000-31599	11175 W VALLEY SPRING PL	91602	2	165B173   548	2366009009	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.14812	-118.37402	PV1.  Install 10 kW roof mounted grid tied PV system. Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8445	18041-10001-33869	8900 W VENICE BLVD	90232	5	120B169    20	4312014093	(T)(Q)M1-2D	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.02908	-118.38822	SUPP. PC FOR NEW FIRE ALARM SYSTEM.REDISGN OF ENTIRE SYSTEM WITH REDUCTION IN DEVICE COUNT PER LAFD. TOTAL DEVICE COUNT 262 DEVICES WITH 6 PANELS (1 FACP AND 5 RPS). THIS IS PLAN CHECK ONLY SEE APPLICATION COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8446	16041-20001-17784	7900 N BALBOA BLVD Building F	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	01/09/2017 Changes to an approved set of plans. Changes include the addition of a house panel and electrical equipment. *****Previous Work Description*****Plan check for power and energy. Project site is a new aircraft hangar. Plan check per Article 513, Aircraft Hangars. Work includes a new 400-amp service, (8) panel boards, and associated load. Total lighting area = 29,360 sq. ft.Note: Building permit has been pulled under 15010-30000-03329	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8447	18041-10000-43600	2617 S MIDVALE AVE	90064	5	123B157   252	4256030004	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.0358	-118.42643	Plan check for a 3.6KW AC PV1 roof mounted system with (10) AC module interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8448	18041-10001-03772	5621 W BOWCROFT ST	90016	10	117B173    67	5025005025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2018 12:00:00 AM			PC Approved	02/06/2018 12:00:00 AM	ADDRESS	34.02026	-118.36784	Supplemental PC for changes to approved set. Changing PV panel layout on roof.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8449	14041-10000-33803	1170 S ALVIRA ST	90035	5	132B173  1097	5087014014	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.05486	-118.37207	PV1.  Install 7.395 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8450	15041-20000-18400	1507 N NOLDEN ST	90042	14	157-5A227 183	5485001017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.12583	-118.19483	PC FOR PV1 SDFD. TOTAL SYSTEM SIZE 6KW AC USING STANDARD PLAN. SYSTEM USES POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8451	14041-10000-04613	9043 N LURLINE AVE Bldg 6	91311	3	198B109   193	2780001058	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.23512	-118.58442	PC for power and energy. BLDG 6. (3 of 4)NEW SPEC CONCRETE TILT UP INDUSTRIAL BUILDINGS; 1-STORY WITH MEZZANINE (BUILDING 6) OFFICE- 5,000 SQ.FT.; WAREHOUSE - 23,097 SQ.FT.HAVE APPLICANT VERIFY 20700 NORDHOFF ST. WITH B.O.E. ADDRESS COUNTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8452	12041-10001-19471	3115 S PURDUE AVE	90066	11	120B153   812	4250021022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2012 12:00:00 AM			PC Info Complete	10/22/2012 12:00:00 AM	ADDRESS	34.0241	-118.43241	SUPPL. APPLICATION FOR CHANGES TO THE APPROVED PLANS. REDUCED THE NUMBER OF MODULES OF A  PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE FROM 29 TO 27.  PERMIT WAS ISSUED UNDER 12041-10000-19471.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8453	13041-20000-18656	735 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	T24 FOR EXISTING MALL SHELL FOR TENANT PREP IN THE CORRIDOOR. TOTAL SQRFT 1350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8454	19041-20000-07986	5616 N CALHOUN AVE	91401	4	174B153   730	2245027007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.17273	-118.44202	Plan check for a PV1 roof-mounted PV system. System size is 7.2 kWdc/6 kWac and consists of (1) inverter and (24) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8455	13041-10000-00707	2001 S ROXBURY DR	90035	5	129B165   815	4307014013	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00, 2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2013 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.04728	-118.40151	PV1 for single story single family dwelling microinverters. Using standard plan. System size: 9.9 KW. [Module: Solar World {Sun module SW240POLY}] [Microinverter: Enphase energy {M215-60-2LL-322/23}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8456	11041-10000-27202	3501 W JEFFERSON BLVD	90016	10	120B185   804	5051029029	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM				PLAN CHECK POWER AND ENERGY. NEW 1000A SERVICE ELECTRICAL SYSTEM TO EXISTING COMMERCIAL BLDG;LOAD IS ON HOUSE PANEL ;OTHER FEEDERS ARE STUBBED OUT; TITLE 24 PLAN CHK IS FOR THE ELECTRICAL ROOM ONLY;TENANT(S) WILL DEVELOPE THE REST OF THE COMMERCIAL SPACE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8457	14041-10002-32438	200 WORLD WAY # 236	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM			PC Approved	06/15/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	CHANGES TO AN APPROVED SET. NOTE CHANGES ON DELTA 6. (((PC FOR POWER AND ENERGY. TERMINAL 2 PICK UP STIX (236). TI. TOTAL AREA 745 SQ FT.PLAN CHECKER TO VERIFY THE FEES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8458	13041-20000-18835	10522 N LURLINE AVE	91311	12	207B109   559	2707010039	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.26166	-118.58404	PV1 SINGLE FAMILY6 DWELLING. SYSTEM SIZE 7.5 KW USING 35 MODULES. USING ENPHASE MICROINVERTER. STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8459	17041-10001-42224	2305 S PADUA PL	90291	11	108B149   840	4237009006	R3-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	33.99194	-118.45582	PC  FOR A LOST SET OF PLANS, PERTMIT UNDER MASTER PLAN. #17041-10000-42224PC for a new AC Power Wall(5.8KVA / 13.5KWH) and one new 125A Subpanel for single family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8460	14041-20000-08614	14724 W VENTURA BLVD suite1115	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.15162	-118.45395	energy plan check suite 1115	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8461	16041-20000-45017	1451 E 4TH ST	90033	14	127-5A219 339	5172020019	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.04249	-118.22532	Commercial office TI in (E) 2-story commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8462	17041-30000-08124	12900 W VANOWEN ST	91605	2	180B161    77	2326001031	C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.19373	-118.41424	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,035 sq. ft. Submitted per applicant request.Note: Building application has been generated under 16016-20000-25220	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8463	17041-20000-37048	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	04/23/2018 12:00:00 AM		Issued	04/23/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	New electrical control panel and wiring for biosparge system.  Wiring passes through hazardous classified area.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8464	15041-20001-29142	4910 N ABBEYVILLE AVE	91364	3	168B093    82	2074022018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	34.1596	-118.63201	Expedite fees only.   Installation of new roof mounted solar PV array.  Total system size = 11.61 kW.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8465	14041-10000-16092	3030 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.01653	-118.21498	Plan check for power only. Addition of (1) 800A 480/277 3p4w 65kaic meter with GFI to (E) SERVICE EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8466	17041-10000-28860	1717 N VINE ST 1ST FLR	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Info Complete	08/15/2017 12:00:00 AM	ADDRESS	34.10222	-118.32701	PC for T24 only for new lights in restroom. Total affected area is 357sqft. Building# 17016-10000-20206.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8467	16041-20000-00485	7320 N WOODLAKE AVE	91307	12	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.20263	-118.63189	$0 permit fee is due to State Senate Bill SB-1222.  Plan check for a PV2 roof-mounted PV system. System size is 84 kWac and consists of (3) inverters, (360) modules, and (1) load center. Project site is an existing medical building.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8468	17041-20000-42494	5350 N RIVERTON AVE	91601	2	171B177   168	2416023003	MR1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.16803	-118.36523	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,216 sq. ft.Note: Building permit has been issued under 17016-20000-02689.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8469	16041-20000-18437	5625 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	33.93197	-118.382	Plan check Title 24 only for existing space office Los Angeles Wrorld Airport. Total area: 1,762  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8470	15041-20000-27457	6844 N WOODMAN AVE	91405	2	183B157   830	2328012040	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.19531	-118.43098	Installation of new fire alarm system in new 15 unit apartment building.  59 devices + 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8471	16041-20000-14435	2347 N TEVIOT ST	90039	13	147A209    69	5440005011	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.09858	-118.25825	PV1.  Install 2.4 kW DC roof-mounted PV system.  Central inverter standard plan.  (8) modules with (1) 3 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8472	17041-10000-29839	600 N PACIFIC AVE	90731	15	018B197   216	7449001026	MR1-1VL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.74791	-118.28769	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8473	19041-10000-04033	1600 N VINE ST	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Issued	02/01/2019 12:00:00 AM	ADDRESS	34.1	-118.32647	Design build: Plan check for modification in place located in a commercial buiding. Scope includes a total area of 15,000-SQ FT. Portion of the permit fee is paid under 18041-10000-05405.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8474	13041-10000-35040	6600 N TOPANGA CANYON BLVD 42B	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR POWER AND ENERGY PER APPLICANTS REQUEST. MERCANTILE TENANT IMPROVEMENT FOR SPACE # 42B, TOPANGA MALL .BUILDING PERMIT # 13016-10000-25754	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8475	14041-20000-17063	7454 N RIVERTON AVE	91352	2	186B177   310	2410008001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Expired	08/08/2016 12:00:00 AM	ADDRESS	34.20639	-118.36582	PV1Install roof-mounted solar array on SFD. System size: 3.6kW(1) Power One Aurora PVI-3600-OUTD-US-A transformerless inverter(13) Renesola JC250M-24 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8476	14041-10000-16097	3020 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Expired	07/27/2016 12:00:00 AM	ADDRESS	34.01664	-118.21526	Plan check for power only. Addition of (1) 800A 480/277 3p4w 65kaic meter with GFI to (E) SERVICE EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8477	15041-20000-26773	6320 N TOPANGA CANYON BLVD G1660	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Issued	08/21/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title-24 (energy).  Total area = 1,590 sq. ft.  T.I. to commercial first time tenant.  New lighting, recepticles, and HVAC for barbershop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8478	14041-20001-06230	1050-1052 S FAIRFAX AVE	90019	10	132B177   855	5086001046	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM			PC Approved	07/24/2014 12:00:00 AM	ADDRESS	34.05671	-118.36432	Modification to approved set.  Addition of lighting to mezzanine level and slight modifications to lighting on first floor.  (((T24 FOR EXISTING RETAIL SPACES. PERMIT HAS BEEN PULLED ON APPLICATION#: 13041-20000-33175)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8479	12041-10000-11424	735 S FIGUEROA ST SPACE #-114	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM			Corrections Issued	06/20/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	INTERIOR TENANT IMPROVEMENT FOR LAMILL COFFEE SHOP  IN EXISTING FOOD COURT(~911 S.F.)  Load is around 210 Amps, per applicant and occpancy load is less than 99.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8480	15041-10000-30865	687 S HOBART BLVD	90005	10	132B193   184	5093006033	(T)(Q)C2-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.0605	-118.30557	PC FOR POWER AND ENERGY. NEW MIXED USED BUILDING. 7-STORY, 346 UNITS. 32 TYPICAL UNITS.  2  PARKING LEVEL ABOVE GROUND AND ONE SUBTERRANEAN LEVEL. TOTAL AREA 254860 SQ FT.address has been updated to match building permit. 11/9/15	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8481	15041-20000-29402	6917 N NITA AVE	91303	3	183B101   580	2024036016	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.19586	-118.61383	Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter, (38) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8482	13041-20000-35170	600 S LA BREA AVE	90036	4	135B181   585	5507023026	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.06474	-118.34381	PC FOR T24 ENERGY ONLY. OFFICES NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8483	13041-10001-04320	1829 N AVENUE 55	90042	14	157-5A227 214	5479009023	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM			PC Approved	06/21/2013 12:00:00 AM	ADDRESS	34.1256	-118.19781	Changes to approved set.  Modules REC 245 PE BLK changed to REC 250 PE BLK.  Original work description: PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. PC FOR PV SYSTEM. USING ENPHASE M215-60-2LL-S22. USING SOLAR PANELS REC 245 PE. TOTAL SIZE 3.624KW. 17MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8484	10041-20000-17423	349-351 N FAIRFAX AVE	90048	5	138B177   147	5527036014	C2-1VL	Central	Wilshire	Mid City West		1945.00, 2144.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	05/27/2011 12:00:00 AM	PIN	34.07764206	-118.36177355	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM CATERING/TAKE OUT  RESTAURANT TO RESTAURANT (TYPE A OCCUPANCY).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8485	19041-10000-02567	15001 S FIGUEROA ST	90248	15	072B201    60	6120029009	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			Reviewed by Supervisor	02/06/2019 12:00:00 AM	ADDRESS	33.89604	-118.28344	CHANGE OF USE OF SECOND FLOOR FROM WAREHOUSE TO NURSERY. EXISTING 1200 AMP SERVICE. NEW PANELS, TRANSFORMER & LOADS. NOTE: BUILDING PERMIT # 19016-10000-01579 HAS NOT BEEN ISSUED YET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8486	17041-10000-21040	15530 W LANARK ST	91406	6	189B145    63	2654040003	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.2184	-118.47102	PC for title -24  only. Remove HID fixtures and replace with new LED fixtures. total affected area 17500 sq.ft (indoor/outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8487	16041-10001-09077	450 S WESTERN AVE #216	90020	10	135B193   649	5503014020	R3-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	FULL PC FOR FIRST TIME TENANT. TITLE 24 ALREADY APPROVED AND PERMIT ISSUED UNDER MASTER. THIS PLAN CHECK IS PC ONLY FOR POWER SYSTEM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8488	15041-20000-41084	14225 W DICKENS ST	91423	4	165B153   468	2266003102	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Apartment			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.14885	-118.44292	NEW FIRE ALARM SYSTEM FOR AN 18 UNIT APARTMENT BUILDING (TOWNHOUSE). TOTAL NUMBER OF FIRE ALARM DEVICES IS 72, 1 FIRE ALARM PANEL, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8489	19041-10000-19156	3350 W WILSHIRE BLVD PODIUM	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.04	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	11/04/2020 12:00:00 AM		Permit Finaled	11/25/2020 12:00:00 AM	ADDRESS	34.0615	-118.29586	exterior luminaires for pedestrian walkway on the PodiumPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8490	19041-20000-11633	1978 E 114TH ST	90059	15	087A215   400	6067002052	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.93136	-118.23641	Installation of 27 kWh energy storage system and 50A EV charger circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8491	10041-10000-13070	649 W 34TH ST 1st FLOOR	90089	8	120A201   206	5123023024	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM	07/12/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	PIN	34.02214675	-118.28186522	USC PARKING STRUCTURE 'D', NEW OFFICES AND CORRIDORPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8492	19041-20000-02000	10971 N CARTWRIGHT DR	91311	12	210B113   244	2708029003	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.27059	-118.56661	pv1install roof mounted pv system sized 5.7KW AC interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8493	14041-20000-18672	8110 N SHIRLEY AVE	91335	3	189B117   169	2105015015	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.2173	-118.55778	PV1 Standard plan, roof-mounted system with 5.3KW , 21Trina Solar TSM 255P modules and  one Power-one Aurora PVI 3.6 OUTD inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8494	19041-10000-35838	5251 N GENESTA AVE	91316	5	171B133   209	2258028024	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.16667	-118.5034	0$ FINAL FEES PER AB1414 [EPLAN] PLAN CHECK FOR ROOF MOUNTED 14.4 KVA SYSTEM CONSISTING OF 2 INVERTERS(SE11400H-US & SE3000H-US) WITH  49 MODULES USING P370 OPTIMIZERSMAIN BREAKER DERATING UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8495	18041-10000-03956												Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			Corrections Issued 2	02/02/2018 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8496	10041-10004-03918	3327 E SABINA ST Bldg C	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	01/19/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 4 revisions to approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8497	19041-10000-26377	5252 W ADAMS BLVD	90016	10	123B177  1008	5043004014	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.03226	-118.35735	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8498	18041-20000-19254	10015 N PETIT AVE	91343	12	204B137   925	2685003011	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Re-Activate Permit	11/14/2019 12:00:00 AM	ADDRESS	34.25254	-118.49818	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (31) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8499	19041-20000-38624	3766 S MOTOR AVE	90034	5	120B165  1371	4314004009	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			09/25/2019 12:00:00 AM	03/12/2020 12:00:00 AM		Permit Finaled	04/01/2022 12:00:00 AM	ADDRESS	34.0212	-118.40424	POWER AND ENERGY PLAN CHECK FOR NEW 1000A SERVICE, LIGHTS, OUTLETS, EQUIPMENT, AND T24. TOTAL SQUARE FOOTAGE = 23094 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8500	14041-20001-01866	8144 N RANCHITO AVE	91402	6	192B153  1137	2213010002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/02/2014 12:00:00 AM	ADDRESS	34.21912	-118.43613	((EXPEDITE FEES)))pv1 single family dwelling. total system size 5kw ac using 22 modules. using transformerless inverters with power optmizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8501	13041-10000-24615	15730 W MARILLA ST	91343	12	201B141   341	2671004013	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.24725	-118.47487	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION,INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE 3.75KW DC IN 2-STORY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8502	13041-20001-22722	2323 W LOY LANE	90041	14	162A221   165	5682020014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.13773	-118.21812	((EXPEDITE FEES))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8503	19041-10000-21556	316 N WESTERN AVE	90004	10	138B193   365	5521027013	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	05/04/2020 12:00:00 AM		Permit Finaled	09/21/2022 12:00:00 AM	ADDRESS	34.0769	-118.30892	PROVIDE NEW ELECTRICAL 600 AMP 120/240 3PHASE SERVICE. PROVIDE (2) 400 AMP DISTRIBUTION BOARDS. INSTALL NEW PANELS, EQUIPMENTS AND LIGHTS. BULDING PERMIT: 18014-10000-05811	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8504	14041-20000-06427	4365 N MAMMOTH AVE 1-24	91423	4	165B153   378	2271017027	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	34.15002	-118.43269	Roof mounted PV system with 32.94KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8505	16041-20000-16712	1935 S ARMACOST AVE	90025	11	123B149   313	4259020015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Expired	06/14/2018 12:00:00 AM	ADDRESS	34.03542	-118.45478	Installation of (1) HVAC unit and (4) fans to (E) single-story commercial building.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8506	16041-10004-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM			Not Ready to Issue	06/26/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Power plan check only, changes to approved set noted as Delta-12 and 13, feeders change from Copper to Aluminum. Feeder length, Voltage drop and If calculation is revised accordingly.<<<PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT. BUI;DING APPLICATION 16010-10000-04147>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8507	17041-20000-44806	19347 W VENTURA BLVD	91356	3	174B117   294	2163001008	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.17288	-118.55519	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the dining area. Total lighting area = 2,210 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8508	18041-10000-21180	11949 W FOXBORO DR	90049	11	132B141   146	4404017004	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			Reviewed by Supervisor	06/13/2018 12:00:00 AM	ADDRESS	34.06058	-118.47367	INSTALL 4 @ 13.5 KWH STORAGE BATTERY SYSTEM IN A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8509	12041-10002-24686	3155 N STONE OAK DR	90049	11	159B137   500	4490010008	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2013 12:00:00 AM			Corrections Issued	01/28/2013 12:00:00 AM	ADDRESS	34.1293	-118.49713	9.8 kw roof mounted PV for a singlefamily. (Enphase M215). MONITORING SYSTEM HAS BEEN ADDED TO PERMIT FEE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8510	14041-10000-07880	13730 W ROSCOE BLVD MDCAL GRP	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.22149	-118.43179	T24. TWO STORY BUILDING,MEDICAL GROUP. EMERGENCY LIGHTING,UNIT EQUIPMENT.TOTAL AREA 1351 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8511	17041-10000-34393	3550 S LA BREA AVE	90016	10	120B177  1042	5046013007	CM-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Closed	08/10/2020 12:00:00 AM	ADDRESS	34.02193	-118.3554	REPLACE EXISTING FIXTURES WITH LED FIXTURES- TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8512	11041-20001-12644	16830 W KINGSBURY ST	91344	12	207B133   675	2684018036	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Apartment			07/27/2011 12:00:00 AM			Verifications in Progress	08/25/2011 12:00:00 AM	ADDRESS	34.26299	-118.4993	Plan check new roof mounted 155KW Photovoltaic system on apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8513	12041-20001-22371	21301 W BLACKHAWK ST	91311	12	204B105   834	2706021045	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	ADDRESS	34.25899	-118.5954	INSTALL ROOF MOUNTED PHOTOVOLATIC SYSTEM using Enphase Microinverters.  6.9kw.  PLAN CHECK ONLY, Permit is on the main application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8514	15041-10000-32662	1050 W PACIFIC COAST HWY 1st Floor	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Expired	12/14/2017 12:00:00 AM	ADDRESS	33.79072	-118.29449	T-24 Install outlets and light fixtures in the optometry sales area. NO EXAM ROOM included in the scope.Scope of work located inside Kaiser Permanente Build. 1st Floor. Total area: 1894 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8515	16041-10000-18790	617 N DILLON ST 1-49	90026	13	141A203   375	5401014013	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.07899	-118.27903	Full PC for a new four story 49 unit apartment with subterreanean parking. Located in a methane zone area.  New 2500 Amp service 120/208 U.G.P.S. It includes 29 typical units. Total sqft = 40,517.*** plan checker to verify the number of circuits for submittal 2 fees (adjustments were made for a pre-made check payment)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8516	14041-10000-35448	21305 W ITASCA ST	91311	12	201B105   210	2746006026	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	PIN	34.24518501	-118.59549206	Title 24 plan check only.  Total area = 12,704 sq. ft.Retrofit existing lights to LED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8517	14041-10000-30086	355 S GRAND AVE	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.05191	-118.2525	Renovation of multi-tenant corridor within the Wells Fargo Center, South Tower. Plan check for power and lighting. Lighting area = 3,299 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8518	18041-10003-18230	8525 N VARIEL AVE	91304	3	192B105   176	2779011036	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2018 12:00:00 AM			PC Approved	07/23/2018 12:00:00 AM	ADDRESS	34.22506	-118.59302	07/23/2018PC only, Changes to an approved set of plans, Changes include the revision of PV feedback connection to main panel board. Note changes on delta 2. __________________________________[[[7/13/18 CHANGES TO APPROVED. PLANCHECK ONLY FOR DELTA 1 CHANGES. CHANGES INCLUDE RELOCATING THE INTERCONNECTION OF SOLAR INTO EXSITING 400AMP 120/240 SPLIT BUS SINGLE PHASE SERVICE]]]]PV1, roof mounted solar system using central inverters. (88) modules and (3) 7KW inverters. Total system size is 21KWAC and 23.6 KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8519	17041-20000-21630	5601 N DE SOTO AVE 3rd Floor	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.17126	-118.58861	TI to an existing medical office.  Plan check for power and energy.Associated building permit: 16016-20000-27270	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8520	17041-20001-22482	8517 N GEYSER AVE	91324	12	192B121   248	2785011044	R1-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.22509	-118.54274	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.5kW ungrounded system. (22) 255W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8521	18041-10001-33164	108 S FREMONT PL WEST	90005	4	132B185   290	5090018010	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.05945	-118.32826	NEW ROOF MOUNTED 16.8 KW PV SYSTEM WITH 56 MODULES, ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8522	14041-10000-25854	25975 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	33.78721	-118.29774	Title 24 plan check for an office TI in a single story building; lighting retrofit from existing fixture to LED retrofit kits. Total remodeling area covers 16028 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8523	18041-10000-28536	5500 W JEFFERSON BLVD	90016	10	120B173  1730	5047015033	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.02557	-118.3665	97 additional devices to an existing methane detection system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8524	14041-10000-05596	2528 S FIGUEROA ST	90007	9	121-5A203  26	5124027016	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.02852	-118.27554	pc for t24 only. permit to be pulled at EPC counter only. 13016-10000-23251 building description: REMODEL OF 25' X 50' (E) RESTAURANT WITH NON-BEARING PARTITIONS, FINISHES, FIXTURES, SUSPENDED CEILINGS AND RELATED MILLWORKS; RELOCATE TYPE I HOOD WITHIN KITCHEN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8525	19041-10000-11527	2410 N HYPERION AVE	90027	4	148-5A205  62	5432003025	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.10298	-118.27293	NEW FIRE ALARM -SPRINKLER MONITORING SYSTEM IN AN OFFICE SPACE. SCOPE INCLUDES NEW FACP, ANNUNCITOR AND 5 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8526	18041-20000-24497	5050 W PICO BLVD	90019	10	129B181  1004	5070017003	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Apartment			06/29/2018 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	09/20/2021 12:00:00 AM	ADDRESS	34.04771	-118.34793	New 6 story mixed use building with 79 dwelling units. 2000A 208Y/120V 3ph-4w service.   Building permit filed under 16010-10000-05000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8527	16041-10000-17164	1840 S CENTURY PARK EAST 15TH FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	T-24, PC FOR ENERGY ONLY.  INTERIOR OFFICE TI AT 15TH  FLOOR OF AN EXISTING HIGH RISE BUILDING. TOTAL AFFECTED AREA IS 14833 SQ. FT.  B # 16016-10000-09983.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8528	18041-20000-36849	22557 W HATTERAS ST	91367	3	174B097   144	2040046001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.17598	-118.61867	Plan check for a PV1 roof-mounted PV system. System size 15.8 kWdc/13.4 kWac and consists of (48) modules, (48) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8529	14041-10002-31079	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM			PC Info Complete	05/03/2016 12:00:00 AM	ADDRESS	34.0834	-118.37568	04/01/16CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE ADDITION TO THE CORE AND SHELL. ADDITIONS INCLUDE RESTROOM BUILDOUTS, SHOW WINDOWRECEPTACLES AND PANELS WITH ADDED LOAD FOR 5 UNITS. Clarify that building is retail use. clarify green building requirements aswell. (((revisions to lighting system(((Plan check for power and energy. New 800 A service upgrade for a 2-story building (retail space). Total indoor lighting area = 1,360 sq. ft. Total outdoor lighting area = 800 sq. ft. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8530	17041-20000-18542	18518-18538 W LANARK ST	91335	12	189B125   165	2103009039	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.21735	-118.5372	pv2install roof mounted pv system sized 9kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8531	17041-10000-35168	6245 W WILSHIRE BLVD	90048	5	135B177   481	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.06356	-118.36478	PC FOR METHANE DETECTION SYSTEM IN A MIXED USE BUILDING. SCOPE INCLUDES PANEL AND 27 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8532	19041-20000-44416	10959 W KINROSS AVE	90024	5	132B149    99	4363025001	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.06012	-118.44693	TENANT IMPROVEMENT ADD NEW LIGHTS PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8533	14041-20001-09228	16360 W BRYANT ST	91343	12	195B137   921	2689027032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	05/15/2014 12:00:00 AM	ADDRESS	34.22739	-118.48948	EXPEDITED BY APPLICANTS REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8534	18041-20000-35857	17717 W LEMARSH ST	91325	12	204B129   234	2734001016	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM			Not Ready to Issue	09/19/2018 12:00:00 AM	ADDRESS	34.25604	-118.52046	Plan check for a PV1 roof-mounted PV system. System size is 16.8 kWdc/15 kWac-CEC and consists of (2) inverters, (1) load  center, and (48) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8535	11041-10000-23782	3580 W WILSHIRE BLVD #600	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM	11/07/2011 12:00:00 AM		Permit Finaled	01/12/2012 12:00:00 AM	ADDRESS	34.06156	-118.3028	TENANT IMPROVEMENT - DEMO NON-BEARING INTERIOR PARTITIONS; NEW NON- BEARING WALLS; NEW FLOOR AND WALL FINISHES.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8536	13041-10000-24740	11565 N BORDEN AVE	91331	7	213B161   520	2533024008	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.28036	-118.41322	PV1 ROOF-MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL IN A SINGLE STORY HOME. SYSTEM SIZE IS 4.17KW DC. (17) TRINA 245 MODULES, (1) POWER-ONE-4.2-OUTD-S. DC UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8537	16041-10000-37003	17325 W CASTELLAMMARE DR 1-29	90272	11	126B117   727	4416003038	[Q]RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			10/19/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM	ADDRESS	34.03943	-118.55625	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 29 UNIT APARTMENT BUILDING. SCOPE INCLUDES 183 FA DEVICES, AND 8 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8538	16041-10000-14380	720 S ST LOUIS ST	90023	14	124-5A221  31	5183022010	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.03719	-118.2181	PV1 SFD, TOTAL SYSTEM SIZE IS 3.8KW AC. USING CENTRAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8539	12041-10000-02193	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/30/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.14246	-118.2705	Ti in the entrance of a commercial Bldg. EPC is for T24.  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8540	15041-10000-40110	888 S OLIVE ST 1st fl	90014	14	127-5A209 127	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	PC FOR POWER AND ENERGY ONLY. FIRST TIME TENANT TO A 33 STORY MIX USE APARTMENT BUILDING.  SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTACLES TO A COFFE SHOP. TOTAL AREA 1350 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8541	16041-10002-41263	3345 W WILSHIRE BLVD 1ST FL	90010	10	132B197    22	5502028020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	04/17/2020 12:00:00 AM	ADDRESS	34.06193	-118.2963	DELTA 4 CHANGES TO AN APPROVED SET. CHANGES TO THE LOCATION OF PANELS, ADDITION OF NEW PANEL L1a1, ADJUSTING LOADS AND ADDITION OF CIRCUITS FOR GYM AND LAUNDARY ROOM. ALL CHANGES CLOUDED UNDER DELTA 4.(((((((PC FOR POWER AND ENERGY.  ADAPTIVE REUSE CONVERSION OF A 12 STORY OFFICE BLDG TO 202 LIVE-WORK UNITS. 9 TYPICAL UNITS. EXISTING SERVICE.  TOTAL AREA  58292 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8542	10041-10000-18196	6520 W FOOTHILL BLVD #102	91042	2	201A203   251	2564012038	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.2455	-118.27482	"TI in an exting ""SUBWAY"" restaurant in unit #102.  Plan Check is for T-24 Energy Calcs ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8543	15041-10000-43485	5900 W WILSHIRE BLVD #100	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM			PC Approved	12/24/2015 12:00:00 AM	ADDRESS	34.06237	-118.35809	PC for energy only, installing new emergency ligting in existing office building. Total sq ft = 348	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8544	14041-10000-15859	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Issued	06/13/2014 12:00:00 AM	PIN	34.05182951	-118.41257696	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP AND 82 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8545	11041-10000-05112	6464 W SUNSET BLVD	90028	13	147A187   158	5547026001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.09782	-118.33125	Ti in an existing office Bldg (16 & 17th floors) Panels are existing , all the branch circuits are new. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8546	18041-10000-02165	711 W 27TH ST 1-51	90007	9	121-5A203  19	5123017007	P-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			01/19/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.02836	-118.27921	AT THE ANNENBERG APT BUILDING, UPGRADE SERVICE AND REPLACE RESIDENCE DISTRIBUTION BOARDS AND EXTEND FEEDERS TO HOUSE DISTRIBUTION BOARD AND FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8547	15041-20001-33429	4744 N YARMOUTH AVE	91316	5	168B129   455	2182023007	RA-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			Reviewed by Supervisor	10/23/2015 12:00:00 AM	ADDRESS	34.1568	-118.51982	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (25) modules, and (1) combiner box. Main service panel size is 400 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8548	12041-20000-29399	2053 N SYCAMORE AVE	90068	4	150B181   291	5549024042	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.10802	-118.34185	PV-1. Enphase micro inverter. 5kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8549	11041-10000-27009	1833 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1-1, C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM			PC Approved	01/31/2012 12:00:00 AM	ADDRESS	34.04342	-118.37677	T.I. to existing building.  Install genral/emergency lighting at the exercise room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8550	17041-20000-45328	4342 N TALOFA AVE	91602	4	165B181   222	2424025003	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.14984	-118.35132	permit fee $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 11.7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8551	11041-10001-25912	3023 S WESTERN AVE 1-60	90018	10	120B193   522	5053006903	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Apartment			05/15/2012 12:00:00 AM			PC Approved	05/15/2012 12:00:00 AM	ADDRESS	34.02667	-118.30906	Delta 4 revisions to approved sets of plans. Attached to the plans are the lists of changes made and the corresponding sheet on which the changes were made.CONSTRUCT NEW 4-STORY, 60-UNIT, TYPE VA, AFFORDABLE HOUSING BLDG W/ FIRST LEVEL FOR PKG AND RESIDENTIAL/COMMON AREA. NFPA-13 automatic fire sprinkler sytem for story and allowable floor area increase. Variance is filed to separate the FA PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8552	16041-10000-42610	695 S SANTA FE AVE	90021	14	124-5A2171363	5164019026	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	09/04/2020 12:00:00 AM	ADDRESS	34.03508	-118.23039	New 7-story, 320-units, mixed-use Bldg w/ Commercial space over 2-levels of subterranean Parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8553	14041-10000-11097	725 S HIGHLAND AVE	90036	4	132B185    63	5507028005	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.0613	-118.33856	PV1 4KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(16)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8554	13041-10001-15927	9616 W PICO BLVD	90035	5	132A167   260	4306001037	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM			PC Info Complete	05/14/2014 12:00:00 AM	ADDRESS	34.05497	-118.39811	(((5/14/14- Changes made to approved set. Added 2 ovens. Load calc to be verified)))pc for power and energy. interior remodel of the (e) ralphs store, removal and replacement of sales area and food prep area fixtures with all associated electrical items. remodel (e) interior lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8555	18041-20000-48203	1529 W COLORADO BLVD	90041	14	162A227    37	5669012011	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.13968	-118.1992	PV3.  Install 3.65 kW DC roof mounted grid tied PV system.  (10) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8556	19041-20001-08780	3410 S GRANVILLE AVE	90066	11	117B153   825	4249010003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.01529	-118.43383	NEW 10.5KW AC ROOFTOP PV SYSTEM ON (E) SFD. SCOPE OF WORK INCLUDES (30) 360W SUNPOWER MODULES WITH 30 ENPHASE IQ7 MICROINVERTERS,.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8557	17041-20001-25130	4678 N NATOMA AVE	91364	3	168A111    75	2174018009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.04	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM			PC Approved	07/29/2017 12:00:00 AM	ADDRESS	34.15488	-118.57933	expeditepv1install roof mounted pv system sized 6kw intercnnected with msp.this system is an addition  to an existing pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8558	17041-10000-41898	601 S PALOS VERDES ST	90731	15	015B201   134	7455021034	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	33.73853	-118.28152	PC FOR HOTEL (HIGH RISE)TI TO CONVERT THREE FUNCTION ROOMS TO TWO CONFERENCE ROOMS AND REMODEL FITNESS CENTER FOR T-24 ENERGY ONLY.SCOPE INCLUDES CIRCUITS, LIGHTS AND RECEPTICALS.TOTAL EFFECTED AREA 1515 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8559	11041-10000-17107	3461 W 3RD ST	90004	13	135B197   122	5501013040	C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	PIN	34.06939091	-118.29108439	TI TO AN EXISTING PHARMACY.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8560	17041-10003-04616	20065 W RINALDI ST BLDG A4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.27548	-118.57184	CHANGES TO AN APPROVED SET OF PLANS.  ALL CHANGES ARE CLOUDED UNDER DELTA 48. CHANGES INCLUDE REVISING LIGHTING FLOOR PLANS, REVISING TITLE 24 FORMS, AND REMOVING/RELOCATING LIGHTING FIXTURES.NOTE: PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8561	12041-20001-20697	19850 S MAGELLAN DR	90502	15	057B197    56	7351034065	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	ADDRESS	33.85035	-118.29277	Changes to 1-line. PC only. As-built.Plan check for power and energy. TI to an industrial warehouse. Not a methane zone. 26370 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8562	13041-10001-27660	20731 W MARILLA ST	91311	12	201B109   153	2748004041	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.24819	-118.58529	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8563	15041-10000-19886	145 S FAIRFAX AVE 401, 403 &-405	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	PIN	34.07292853	-118.36175524	T-24 TO AN (E) OFFICE, RENNOVATING THE SPACE. ADDING NEW LIGHTING AND 2- 100AMP PANELS. TOTAL SQ FT. 5825.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8564	15041-20000-07238	3240 N WRIGHTWOOD DR	91604	2	159B173   384	2380037002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.13206	-118.37252	$0 permit fee due to senate bill 1222 from 2012Installation of new roof mounted solar PV array.  Total system size = 18 kWac.  2 inverters with 76 modules (7 strings).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8565	10041-10000-02108	103 S RAMPART BLVD	90057	13	136-5A203  90	5155023017	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2086.20	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM	02/05/2010 12:00:00 AM		Permit Finaled	03/31/2010 12:00:00 AM	ADDRESS	34.0694	-118.27715	T.I. for existing restuarant (Taco Bell).  Install general and emergency lights indoor and outdoor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8566	14041-10000-14133	16962 W OAK VIEW DR	91436	5	165B133    72	2289030006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.1521	-118.5025	PV1 6.75KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-6000-OUTD-US}]. [(27)modules: {Trina {TSM-250PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8567	18041-10000-16592	700-800 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM			PC Approved	05/04/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT  AT PV SHOP AND BREAKROOM AND SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED 1187 SQ. FT. b#18016--10000-13152	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8568	14041-20001-04970	7307 N BALCOM AVE	91335	3	186B129  1134	2121011018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.20329	-118.5209	(((expedite fees)))pv1 single family dwelling. total system size 3.8kw ac using transformerless inverters nonstandard plan, using powre optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8569	10041-20000-06893	"9800 N TOPANGA CANYON BLVD Space ""G"""	91311	12	201B101   171	2746017031	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM	04/15/2010 12:00:00 AM		Permit Finaled	04/21/2010 12:00:00 AM	ADDRESS	34.24856	-118.60584	revise lighting fixtures E	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8570	18041-10000-05214	9301 N TAMPA AVE #184	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only, TI in existing retail space within Northridge Fashion Center. Total area: 3131 sq ft.  <<B# 18016-30000-02252>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8571	12041-10000-13588	20946 W DEVONSHIRE ST	91311	12	204B109   173	2747001091	C2-1, CR-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.25708	-118.59006	Fire alarm plans. One panel and 31 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8572	12041-20000-12039	7901 N LINDLEY AVE	91335	12	189B125   489	2102014018	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.21431	-118.5275	Install new outdoor parking lot lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8573	12041-10000-08396	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Expired	01/05/2015 12:00:00 AM	ADDRESS	34.14246	-118.2705	New fire alarm system for a 2-story healthcare office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8574	08041-10001-09780	7301 W WORLD WAY WEST	90045	11	090B161    67	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM			Corrections Issued	03/09/2010 12:00:00 AM	PIN	33.94534804	-118.41786236	"Plan check for reconnecting existing service to power new distribuiton switchboard ""AA"".  New transformer and disconnect."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8575	12041-10000-29682	375 N SYCAMORE ROAD	90402	11	123B129   640	4410018028	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.03211	-118.51654	PV1 PLAN CHECK ROOF MOUNTED PHOTOVOLTAIC SYSTEM WITH TRANSFORMERLESS INVERTER. SYSTEM SIZE IS 3.36KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8576	14041-20001-10308	4408 N CONCHITA WAY	91356	3	165B117   199	2178030015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.14976	-118.56038	EXPEDITE PER APPLICANT REQUEST(((PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 6.5kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(26) Canadian Solar #CS6P-250PX pv modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8577	19041-10000-40551	310 N BANNING BLVD	90744	15	027B209    50	7424004005	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	08/19/2021 12:00:00 AM		Issued	08/19/2021 12:00:00 AM	ADDRESS	33.77336	-118.25654	Power plan check for a telecommunication system. Scope includes (1) 600-amp service,  (3) panels and other associatied equipmeint.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8578	14041-10000-07317	389 TERMINAL WAY M&R Bldg	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Public Safety Only			03/19/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	PIN	33.74647892	-118.27942177	Upgrade fire alarm system for port of LA M&R BLDG. (2 of 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8579	15041-20000-15601	1680 N VINE ST Suite 300	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for Title 24 only for existing office space. Emergency egress lighting shall be bugeyes equipment unit per fire variance. Total area: 2,841 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8580	13041-20000-35230	6420 W WILSHIRE BLVD SUITE 200	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.06365	-118.36922	PC FOR T24 ENERGY ONLY. EXISTING OFFICES NEW LIGHTING. WORK DONE IN SUITE 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8581	19041-20001-18724	4224 S CLOVERDALE AVE	90008	10	114B177   157	5029041005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2019 12:00:00 AM			PC Approved	09/20/2019 12:00:00 AM	ADDRESS	34.01036	-118.36614	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CLOUDED CHANGES ONLY, REMOVAL OF 2 PV PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8582	14041-20000-15912	22711 W CANTLAY ST	91307	12	186B097   984	2022003017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.20202	-118.62174	PV1 SINGLE FAMILY. USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN. TOTAL SYSTEM SIZE 5.6KW AC with 26 modules and microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8583	17041-10000-20937	13050 W SAN VICENTE BLVD # 107	90049	11	129B137   518	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.0483	-118.49125	PC for power and energy for change of use to medical botox clinic. Total affected area 522 sqft. PC for new receptacles and lighting.Building #17016-30000-13050	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8584	07041-10011-27960	6142 W FRANKLIN AVE	90028	4	150A189   194	5586025001	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			03/23/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM				Delta 1 only modification to plan.  Modifiy loads on panels HA, HB, P, EB, and add two 20 HP sump pump motors with feeder and controller to DPH.  New lighting add  six exterior photo cell controlled luminaires to existing circuit EB-10.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8585	14041-10000-06131	2806 E WASHINGTON BLVD STO#62289	90023	14	118-5A221 110	5169026012	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.0171	-118.21964	TENANT IMPROVEMENT AT A SUBWAY RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8586	18041-20000-01013	10443 N HILLVIEW AVE	91311	12	207B105   678	2722013015	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.2603	-118.60288	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists if (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8587	14041-10001-21131	8510 S LILIENTHAL AVE	90045	11	096B169   435	4107018017	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	33.96071	-118.38599	EXPEDITED PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(15) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8588	13041-10000-26436	3515 W WILSHIRE BLVD 1ST FLR	90010	10	132B193    16	5502032017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.0619	-118.30094	ELECTRICAL PERMIT TO BE PULLED @ THE ELECTRICAL PLAN CHECK COUNTER. TITLE-24 PART-6 LIGHTING, PLAN CHECK AND PERMIT; ADDING NEW LOADS ON 2 EXISTING PANELS RATED 200A.  TI  IS FOR A RETAIL SPACE  (347 SQ FT) ON THE FIRST FLOOR OF WILSHIRE HOTEL. CRA WILL BE CLEARED UNDER THIS APP # .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8589	11041-10001-24382	1020 E LAKE ST BLDG 6-2	90291	11	111B145   517	4243003041	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.00194	-118.46034	Lincoln Place Apartment Building Project.  New 2-story apt. building with 7 units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8590	14041-20000-32926	8021 S WESTLAWN AVE	90045	11	099B161   544	4112025005	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.96632	-118.40882	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING 15 MODULES. SINGLE TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8591	13041-10000-34959	380 W WORLD WAY #T73&T74/	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	PROPOSED 541 SQFT  TENENAT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8592	11041-20000-23916	17221 W BULLOCK ST	91316	12	177B133    25	2255008004	R1-1	South Valley	Encino - Tarzana	Encino		1390.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.1799	-118.50849	Plan check for 5.88KW Enphase Microinverter photovoltaic system single family dwelling. Variance to install M215 prior to Test Lab approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8593	16041-20000-21663	1645 W 36TH PL	90018	8	120B193  1316	5041015006	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Expired	07/25/2018 12:00:00 AM	ADDRESS	34.02214	-118.30735	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8594	19041-10003-03618	654 E VERNON AVE	90291	11	111B145  1229	4239003018	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM			PC Approved	04/04/2019 12:00:00 AM	ADDRESS	33.99767	-118.46818	SUPPLEMENTAL CHANGES TO APPROVED SET ON 6.175 PV SYSTEM. CHANGES INCLUDE CHANGING THE MODULE FROM 325 W TO 330 W.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8595	11041-10004-15257	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	PIN	33.94363002	-118.42513364	Delta 13 changes to approved set of plans (11041-10003-15257). Changes to lighitng only. Plan check for energy only. Restrooms were added to job scope (724 sqft). Emergency lighting was checked on previous set of plans (11041-10003-15257).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8596	14041-10000-29531	3511 W SUNSET BLVD	90026	13	144A203   174	5429024002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	11/03/2014 12:00:00 AM	ADDRESS	34.08918	-118.2764	400 Amp service upgrade under engineer's request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8597	16041-10000-44711	5241 N SUMNER AVE	90041	14	163-5A219  33	5682006005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	01/14/2017 12:00:00 AM	ADDRESS	34.14418	-118.22436	INSTALL NEW ROOF MOUNTED SYSTEM 4.275 KW SOLAR ARRAY ON A SINGLE FAMILY HOOUSE. (15) MODULES; SOLARWORLD SUNMODULE PLUS SW 285-290 MONO BLACK (1) INVERTER: SOLAREDGE SE5000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8598	17041-20001-40106	23838 W BURBANK BLVD	91367	3	174B089   555	2047010018	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM			PC Approved	11/16/2017 12:00:00 AM	ADDRESS	34.17064	-118.64664	expeditepv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8599	10041-20000-23167	15823 W MONTE ST #104-106	91342	7	225B141  1524	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	ADDRESS	34.31094	-118.47588	Power and energy for tenant improvemnt unit 104, 105, 106	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8600	16041-10000-14587	13925 W VENTURA BLVD	91423	4	165B153   474	2271015016	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.14904	-118.43628	T-24, PC FOR ENERGY ONLY. TI TO AN (E) RESTAURANT (MCDONALDS RESTAURANT). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2269 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8601	12041-10000-01625	8525 W PICO BLVD	90035	5	132B173  1243	4332028039	C4-1-O	Central	Wilshire	South Robertson		2164.00	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	03/23/2012 12:00:00 AM	ADDRESS	34.0537	-118.377	First time tenant. TI in a commercial Bldg.  No suite number per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8602	14041-20000-25415	6638 N ENCINO AVE	91406	6	180B129   299	2229011034	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.19154	-118.51408	PV1.  Install 12.75 kW roof-mounted, utility-interactive PV system.  Transformerless inverters with DC-DC converters. FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8603	19041-10001-10399	10923 W WEYBURN AVE	90024	5	135B149   586	4363018034	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM			PC Info Complete	12/05/2019 12:00:00 AM	ADDRESS	34.06274	-118.44623	Change to an approved set, change includes adding 2 devices and rearange light layout	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8604	13041-20000-09199	350 S GRAND AVE # 3400	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	PIN	34.05160512	-118.25169569	Remodel a peortion ot the 34th floor.  Energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8605	18041-10000-15646	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM			PC Approved	04/27/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	"DELTA 4 CHANGES TO APPROVED SET IS TO USE SERIES RATING FOR PANELS ""4NF"", ""4NF1"", ""3NF2"" & ""3NF3"" INSTEAD OF FULLY RATING AT 10,000 A."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8606	17041-30000-46479	400 S CATALINA ST	90020	10	135B197   500	5502011026	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	02/22/2020 12:00:00 AM	ADDRESS	34.06707	-118.29525	Plan check for a fire alarm system for a 5-story, 61-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (187) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8607	15041-20000-26127	15000 W CORONA DEL MAR	90272	11	123B129   711	4411030007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.03145	-118.52276	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (59) modules, (59) power optimizers, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8608	13041-10005-12515	819 S SANTEE ST	90014	14	126A211    46	5145013005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			05/13/2016 12:00:00 AM			PC Info Complete	11/22/2016 12:00:00 AM	ADDRESS	34.04107	-118.25233	Changes to approved set.  Installation of two new 75 kVA transformers to supply elevators.  Feeder size, length, and voltage drop has changed.CHANGE OF USE OF AN EXISTING 93,379 SQFT, 13-STORY BUILDING W/ BASEMENT INTO JOINT LIVING AND WORK QUARTERS PER THE ADAPTIVE REUSE ORDINANCE.  (TOTAL 96 UNITS).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8609	13041-20000-15373	5833 N PENFIELD AVE	91367	3	174B113    23	2153004001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.17675	-118.56916	photovoltaic system for single family dwelling. pv1 using microinverter standard plan. enphase m215. permit application is owner builder. total of 32 modules. 6.9 kw system size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8610	15041-20000-04720	17345 W BURTON ST	91325	12	192B133   318	2201010026	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.22026	-118.51143	PV1CENTRAL STRING INVERTER STANDARD PLAN.  SYSTEM SIZE 6.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8611	15041-10001-06455	11111 W SANTA MONICA BLVD SUITE 700	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			PC Approved	04/13/2015 12:00:00 AM	ADDRESS	34.04771	-118.44481	Change to an approved set, by using new LED fixture (F3 and F4) for F1 and F2. all changes are under delta-P only.(((TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 6087.  SCOPE OF WORK IN SUITE 700)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8612	14041-10000-06276	700 S GAFFEY ST	90731	15	015B197   564	7454002025	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	33.73766	-118.29214	PLANCHECK FOR T24 ONLY. REMODELING CVS PHARMACY. NEW LIGHTING AND POWER MODIFICATION. 1 NEW PANEL. TOTAL AREA 1158 SQ FT, EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8613	11041-20000-21724	5955 N DE SOTO AVE	91367	3	177B105    78	2149002027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02, 1371.02	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.17888	-118.59071	PLAN CHECK T24 ENERGY/EMERGENCY T.I. TO OFFICE OF EXISTING 2-STORY BUILDING. NEW LIGHT FIXTURES AND DEVICES ON EXISTING CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8614	13041-10000-30920	2049 S THAYER AVE	90025	5	129B157   549	4317006022	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.05036	-118.42535	PV1.  Install 5 kW DC roof-mounted PV system on 2-story house, interconnect with main service panel.  Transformerless inverter: SolarEdge SE5000A-US, power optimizer, and  20 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8615	14041-20000-02840	20601 W TIARA ST	91367	3	177B109   177	2151001005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.17722	-118.58179	pv1 single family dwelling total system size 6kw ac using 24 modules. using transformerless inverter nonstandard plan. using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8616	15041-30000-40319	222 N CARMELINA AVE	90049	11	132B141    47	4405004007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.06095	-118.48416	Plan check for power only.  New single family dwelling with 600 A service.  5 subpanels and 20 kVA emergency generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8617	17041-20000-34183	14319 W JOY DR	91331	6	198B153  1029	2644027241	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24167	-118.44518	Plan check for solar pv system, roof-mounted array on SFD.3kW ungrounded system. (12) 305W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8618	10041-20000-08577	11400 W OLYMPIC BLVD SUTIE-170	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.03666	-118.44346	TI IN OFFICE AREA. P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8619	15041-20002-14776	1901 N VISTA ST	90046	4	150B181   228	5572026002	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	PIN	34.1055072	-118.35236837	07-29-2015 Change to approved set of plans. Changes include add 2 j-boxes and combine ouput of 2 combiner/disconnect and run to the inverters. Add 200A sub-panel before Performance Meter{{{{{{6.24.2015 - Changes to approved set. Change interconnection point from MSP of adjacent property to MSP of SFD on same parcel as ground mounted solar array. Changed address from 1900 to 1901 N Vista St. Service panel is same rating, no change to system design, only interconnection location.[Plan check for a ground-mounted PV system. System size is 16kW and consists of (2) inverters, and (48) modules.]}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8620	17041-20000-40197	4617 N LARKWOOD AVE	91364	3	168B097   572	2074002017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Issued	11/14/2017 12:00:00 AM	ADDRESS	34.15516	-118.62822	Plan check for solar pv system, roof-mounted array on SFD.11.4kW ungrounded system. (39) 325W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8621	19041-20000-23768	9530 N JUMILLA AVE	91311	12	201B117   664	2761030036	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.2435	-118.56381	PLAN CHECK FOR NEW ROOFTOP SOLAR ON A EXISTING SFD. SYSTEM SIZE IS 13.735 KW DC/11.674KW AC. SCOPE OF WORK INCLUDES (41) LG 335W PV MODULES WITH IQ7 MICROINVERTERS, AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8622	18041-10001-12939	707 W WILSHIRE BLVD #3630	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	T-24 ENERGY ONLY IN SUITE #3630 ON THE 36TH FLOOR.  ELECTRICAL PERMIT WAS ISSUED UNDER 18041-90000-07441	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8623	18041-10000-17312	2263 W COLORADO BLVD	90041	14	162A221    70	5671016025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.13961	-118.21567	PC FOR EXISTING BANK OF AMERICA INTERIOR TI . TOTAL AFFECTED AREA 398 SQ.FTSCOPE INCLUDES NEW PANELS, LIGHTS, CIRCUITS AND RECEPTACLES. B# 18016-10000-14704	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8624	13041-20000-21709	19800 W VENTURA BLVD	91364	3	174B117   369	2164011027	(T)(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM			Reviewed by Supervisor	08/20/2013 12:00:00 AM	ADDRESS	34.17216	-118.56413	PLAN CHECK FOR POWER AND ENERGY. SEPARATING POWER AND ADDING A NEW 800A SERVICE TO ACCOMMODATE TWO FUTURE TENANTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8625	15041-10000-23931	11970 N SHOSHONE AVE	91344	12	216B129   204	2601051004	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	01/07/2017 12:00:00 AM	ADDRESS	34.28871	-118.51716	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECETD WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8626	16041-20001-13229	13241 N FELLOWS AVE	91342	7	225B149   387	2505024041	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.31108	-118.45127	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (54) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8627	19041-10000-10417	1040 N LAS PALMAS AVE STG 2, 2A	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 2 AND 2A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8628	12041-20000-10675	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	bulletin #155-t.i.Pharmacy revisions/ T-24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8629	12041-10000-12449	6741 W HOLLYWOOD BLVD	90028	13	148-5A185 109	5547010013	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM			PC Approved	06/04/2012 12:00:00 AM	ADDRESS	34.10172	-118.33718	2500 Sqft restaurant. Occupancy is A-2 with 96 maximum per 11016-10000-06482. Plan check for energy only; emergency lighting is existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8630	19041-20000-35347	851 N LA JOLLA AVE	90046	5	144B173   417	5529010049	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.08687	-118.36815	Plan check for PV and Energy Storage System, PV system size: 11.160KW DC, 10.256 AC with 31 PV Modules and 1 inverter(5.0KW) intergrated with PowerGrid Energy Storage Battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8631	13041-10001-07975	102-116 W 5TH ST	90013	14	129A211   155	5149037010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			09/25/2013 12:00:00 AM			PC Info Complete	10/04/2013 12:00:00 AM	ADDRESS	34.04673	-118.2488	"DELTA 3 CHANGES TO APPROVED PLANS. REVISED INSTALLATION OF MINI KICHENETTS AND INSTALL ADDITIONAL RECEPTACLES IN EACH UNIT AND CHANGE MANUAL LIGHT SWITCHES TO OCCUPANCY SENSORS AND WIRELESS REMOTE SWITCHES.Mixed-use apartment/commercial 13-story with basement building.  Historic hotel building with retail spaces on street level and apartment units above.  New services 800A and 1000A.  New main switchboards, panels, transformers, and branch circuits for the kitchennet equipment installation.  Plan check for power and energy.""COMPLY WITH DEPARTMENT ORDER effective date07/11/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".pLAN CHECK ONLY, PERMIT IS EXISTING"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8632	10041-10000-10534	12990 W BRANFORD ST UNIT D	91331	6	198B161   257	2629027011	(Q)MR1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.00	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	04/05/2011 12:00:00 AM	ADDRESS	34.23917	-118.41525	IN THE INSIDE OF A CELLUAR  STRUCTURE, NEW LUMINAIRES AND CKTS; ON THE OUTSIDE , INSTALLING A A NON-LEGALLY REQUIRED STAND-BY GENERATOR, ATM SWITCH AND CKTS.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8633	18041-20000-02618	624 E SANTA CLARA AVE	90291	11	108B145   844	4239029011	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	33.99274	-118.46571	pv1install roof mounted pv system sized 5kw interconneced with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8634	11041-20000-03729	1555 N VINE ST # 110	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1897.01	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	04/08/2011 12:00:00 AM	ADDRESS	34.09923	-118.32707	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR DANCE STUDIO SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8635	11041-10001-04479	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM			PC Approved	05/23/2011 12:00:00 AM	ADDRESS	33.95887	-118.41869	REVISIONS TO PERMITTED SET OF PLANS- ADDITIONS OF LUMINAIRES; PLAN CHK IS FOR TITLE 24 ONLY((((((((INSTALLATION OF EMERGENCY GENERATOR; FIRE PUMP AND FIRE PUMP CONTROLLER WITH ASSOCIATED TRANSFER SWITCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8636	14041-20000-07471	9255 N CORBIN AVE	91324	12	198B117   150	2761001075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.23837	-118.56248	PC FOR RECONNECTION OF EXISTING SERVICE. EXISTING 1200A SERVICE. PC FOR NEW FAULT CURRECT FROM DWP. (new fault shows panel HA needs to be replace with 42kAIC minimum bracing)this application covers plan check fees and permit fee for new 200A panel. Permit fee for reconnection covered under application 14041-20000-02388	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8637	11041-10000-09324	1100 S HOPE ST 104	90015	14	127-5A207 333	5139005***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/09/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.04195	-118.2631	TI TO AN EXISTING COMMON USE AREA FOR EXERCISE ROOM IN A 19-STORY CONDOMINIUM BUILDING.  ROOM 104.  T-24 ONLY, OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8638	16041-20000-15171	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Expired	06/13/2018 12:00:00 AM	ADDRESS	33.78808	-118.29535	PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORTS. 56, 950 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8639	14041-20001-15486	4319 N LA BARCA DR	91356	3	165B117   247	2177005041	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.149	-118.55141	Expedite fee per applicant request.  (((PV1.  Install 15.045 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8640	15041-10003-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	Pc for changes to approved set of plans. changes noted as delta 7,8,9, and 10. Also incorperating changes to 6th floor labelwd delta 1-5. changes include updating floor plan to match architect background. Update circuit desognations and panel schedules. loads have been relocated and updated. PC fee based on time. any permit fees plan check engineer will tabulate.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8641	16041-10001-19094	20978 W BANDERA ST	91364	3	166-5A109  12	2172015048	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.15254	-118.59033	THIS IS PLAN CHECK FOR ADDITION TO EXISTING SYSTEM. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8642	14041-10001-34546	1011 S SERRANO AVE 1-104	90006	10	129B193   356	5080014012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			02/13/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.0522	-118.3065	Changes to an approved set of plans. All changes are clouded. Scope includes adding laundry combo circuits, adding range ovens, and upgrading elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8643	15041-20000-02741	1420 S ABBOT KINNEY BLVD	90291	11	108B145  1446	4238005040	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	33.99036	-118.46532	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY. this applicant is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8644	16041-10000-40371	3377 W WILSHIRE BLVD	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.06193	-118.29742	PC for energy only to a sit down bakery (85 degrees). TI remodel. New lighting and power. Total connected load is less than 400 amps. Total sqft = 2921.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8645	13041-20000-36075	17217 W CANTLAY ST	91406	6	186B133  1101	2227016029	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.20219	-118.5082	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. USING OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8646	16041-10001-42684	10250 W SANTA MONICA BLVD # 2800	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM			PC Approved	02/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set, noted under Delta-8.    Revised feeder size tag 404A from (2) #4/0 to (1) 500KCMIL, this feeder runs from MS-ELA33 to panel HDP. Revised note #1 to leave one set of conduit to be 'spare' and revised volt. drop and fault current calculation consequently.  Permit is still covered under master #16041-10000-42684	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8647	17041-10001-32898	450 S WESTERN AVE SUITE 212	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			PC Info Complete	03/27/2018 12:00:00 AM	ADDRESS	34.06562	-118.30887	FULL PLAN CHECK FOR ELECTRICAL SYSTEM - FIRST TIME TENANAT FOR RETAIL STORE ON EXISTING DISTRIBUTION EQUIPMENT.PC FOR T24 ENERGY HAS ALREADY BEEN DONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8648	17041-10001-20208	14040 W FOOTHILL BLVD	91342	7	225B153   250	2504019049	R3-1-CPIO	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.31435	-118.43968	MODULES WERE REPLACED AS MANUFACTURER FOR ORIGINAL MODULES WENT OUT OF BUSINESS.. PV SYSTEM (310 MODULES 49.509KW AC) WAS ADJUSTED FOR THIS CHANGE OF MODULES.((((((PC FOR PV SYSTEM CONNTECTED TO EXISTING MAIN PANEL. THIS IS COMMERCIAL PV. THIS SYSTEM USES 5 INVERTER, TOTAL RATED 55.6KW AC. THIS SYSTEM NET METERS METER # M19-13751. THIS IS SYSTEM 2/3 ON SAME ROOF. SYSTEM USES POWER OPTIMIZERS. NOTE: Permit fees due are $0 due to senate bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8649	16041-10000-32051	12400 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	33.97727	-118.4065	PC FOR TITLE 24. ENERGY ONLY TOTAL AREA OF 6515 SQ. FTCOMMERCIAL BL ( NOT HIGH RISE) SCOPE INCLUDES LIGHTS AND RECEPTECALES ON EXISTING CIRCUITS. (ONLY 4 NEW B. CIRUCITS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8650	19041-10000-02481	11111 W SANTA MONICA BLVD 5TH FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.04771	-118.44481	ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT OF CORRIDOR AND RESTROOMS FOR EXISTING OFFICE BUILDING ON THE 5TH FLOOR. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 973-SQ FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8651	13041-10000-05236	710 N FRONT ST	90731	15	021B201    13	7440025904	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro, Wilmington		9800.31	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	08/18/2014 12:00:00 AM		Issued	08/18/2014 12:00:00 AM	ADDRESS	33.7518	-118.28623	BERTH 100-102 MARINE OPERATIONS BUILDING. POWER AND ENERGY PLAN CHECK FOR NEW TWO STORY OFFICE BUILDING. FEEDER (SERVICE)  CONDUCTOR SUPPLYING BUILDING PROVIDED BY OTHERS. SITE LOCATED IN METHANE BUFFER ZONE, NO METHANE MITIGATION REQUIRED PER METHANE REPORT. SEPERATE FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8652	11041-10005-12353	620 W 2ND ST	90012	8	132A211    61	5151004913		Central				2075.00	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			Verifications in Progress	10/01/2013 12:00:00 AM	ADDRESS	34.0545	-118.25027	MODIFICATION TO PREVIOUSLY APPROVED SET OF PLANS. CHANGES ARE CLOUDED. LIGHTING AND MISCELLANEOUS CHANGES. SUPPLEMENTAL APP COPIED FROM APPLICATION # 11041-10002-12353 7/22/2013  NEW MUSEUM BUILDING. THIS INCLUDES PANELBOARDS & CIRCUITS.   <<<PARKING BUILDING CHECKED UNDER DIFFERENT APPLICATION.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8653	17041-10000-44929	11111 W SANTA MONICA BLVD 21ST FL	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	ALTERATIONS IN PUBLIC CORRIDOR/LOBBY AND RESTROOMSPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8654	16041-20001-12845	189 S THE GROVE DR STE G-5	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	Recheck of plans - original approved set lost on job site.  (((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE FOR THE GROVE, SUITE G-5. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, ONE NEW 75KVA,  AND ONE NEW 225A PANEL. TOTAL AFFECTED AREA IS 3075 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8655	17041-10000-16577	1736 S NEW HAMPSHIRE AVE	90006	1	126B197   505	5075017007	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.04156	-118.29227	Plan check for power and Title 24.  New two story retail building.  New 1,200 amp 120/208 volt service.  New electrical distribution system on this property to feed existing distribution panel at 1743 S. Vermont Ave.  Total area = 13,430 sq. ft.     Building permit #17010-10000-00433	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8656	13041-10001-17272	6255 W SUNSET BLVD SUITE 900	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 13041-10000-17272. CHANGES MADE TO FIXTURE TYPES AND COUNTS. AREAS AND SQUARE FOOTAGE REMAINED THE SAME.*********************************************************************PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING IN AN EXISTING OFFICE BUILDING (TENANT IMPROVEMENT) SCOPE OF WORK IS LESS THAN 400 A. HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8657	17041-10000-26545	8111 N VENTURA CANYON AVE 1st-2nd level	91402	6	189B157    56	2213020024	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Issued	11/13/2017 12:00:00 AM	ADDRESS	34.21843	-118.42895	T -24, PC FOR ENERGY ONLY. TI FOR AN EXISTING TOILET FACILITY ON THE 1ST AND 2ND FLOOR. SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 813 SQ. FT. B#17041-10000-26545	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8658	09041-20008-20042	137 N SOTO ST	90033	14	127-5A223  76	5183005019	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.20	Electrical	Electrical	Apartment			09/21/2011 12:00:00 AM			PC Approved	09/21/2011 12:00:00 AM	ADDRESS	34.04482	-118.20939	REVISE FIXTURE SCHEDULE AND CONTROL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8659	17041-10000-16276	19150 S HARBORGATE WAY	90501	15	060B193   455	7351002031	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	PIN	33.85746076	-118.30203916	FULL PLAN CHECK OF NEW CONSTRUCTION OF AN EXPRESS CAR WASH INCLUDING CAR WASH EQUIPMENT IN TUNNEL. SERVICE IS RATED AT 600 AMPS. NEW LIGHTING AND POWER. TOTAL AREA IS 23,862 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8660	17041-10000-36675	800 S FIGUEROA ST 11 TH FL	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.04771	-118.26116	replace 11th floor luminaires in the corridor and elevator lobby; new lighting contrtolsPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8661	18041-10001-05471	15210 W ANTELO PL	90077	5	159B145   585	4378005010	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.1288	-118.46136	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include revising single line diagram to reflect as built. Scope include re-using existing feeder conductors to connect to new service. Note: PC only. Permit fees are paid under PCIS#18041-10000-05471	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8662	19041-10000-45892	19916 W REDWING ST	91364	3	174B113   508	2164003010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.17045	-118.56644	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 35  (PANASONIC VBHN330SA17) MODULES, 35 (SOLAREDGE P400) POWER OPTIMIZERS, 1 (SOLAREDGE SE10000H-US) INVERTER, CONNECTED TO AN UPGRADED  225A MAIN SERVICE PANEL. SYSTEM SIZE IS 11.55KW DC & 10KW AC. MAIN SERVICE PANEL UPGRADE UNDER SEPERATE PERMIT (EXPRESS).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8663	16041-10000-10062	2112 W SUNSET BLVD Build. B	90026	13	139-5A207 108	5402035003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.07733	-118.26419	Plan check for power and energy for change of use to retail spaces # for 115,117,119,121,123. MSB located at Build. A  and will feed Build. B. Total area: 5,104 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8664	14041-10001-26873	615 S MANHATTAN PL	90005	10	135B193   931	5503032012	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Apartment			09/29/2014 12:00:00 AM			PC Approved	05/20/2015 12:00:00 AM	ADDRESS	34.06286	-118.3105	Supp app for expedite fees.Installation of new roof mounted solar PV array.  444 modules, 5 combiner boxes, 5 inverters, 131 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8665	13041-20000-15172	10694 W SOMMA WAY	90077	5	144B149   229	4370005039	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.09045	-118.45082	PV1 FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 11.22 KW. 44 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8666	14041-20002-32178	17520 W MAYALL ST	91325	12	204B129   413	2734017003	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.25382	-118.51651	CHANGES TO APPROVED SET OF PLANS. CHANGE IN LAYOUT ONLY. NO CHANGE IN ELECTRICAL DESIGN. PC FOR NEW ROOF LAYOUT. NO PERMIT TO BE ISSUED UNDER THIS APPLICATION.CHANGES CLOUDED DELTA 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8667	15041-20001-30344	2972 N HUTTON DR	90210	5	156B157   224	4385019024	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			Reviewed by Supervisor	09/23/2015 12:00:00 AM	ADDRESS	34.12384	-118.4243	Expedited per customer request.PV1. Install ground mounted PV system sized 12 kW. Interconnected with main service panel. (56) Mitsubishi PV 270W Modules(2) SMA SB 6000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8668	15041-10000-31772	261 S FIGUEROA ST WEST-1ST FLOOR	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Issued	09/29/2015 12:00:00 AM	ADDRESS	34.05546	-118.25446	T24, NEW LIGHTING AND RECEPTACLES TO TWO RESTROOMS IN AN (E) OFFICE BUILDING. PC FOR ENERGY ONLY. TOTAL SQ. FT. 427	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8669	12041-10000-13681	621 S WESTERN AVE 111-117	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	CHANGE OF USE OF 1ST FLOOR TENAT (7) SPACES FROM RETAIL TO RESTAURANT AND AMUSEMENT ENTERPRISE.  Existing service.  Full Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8670	16041-10000-01907	1830 W SLAUSON AVE Store 1039	90047	8	105B193  1872	6001001023	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	33.98779	-118.31204	New 210 kW fuel cell system, interconnected to (E) service 480/277V. Fuel Cell utility interactive.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8671	15041-10000-36971	12401 W HELENA ST	90049	11	129B141   252	4405038003	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.05164	-118.47935	PV1, INSTALL ROOF MOUNTED PV SYSTEM SIZED 14.25KW INTERCONNECTED WITH MSP. (57) SW-285 WATT SOLAR WORLD MODULES (57) ENPHASE 250 MIRCOINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8672	17041-10000-08468	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			PC Info Complete	03/16/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	PC FOR TRAINING ROOM UPGRADES. NEW PLUS AND NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8673	14041-10000-31991	1837 S LA CIENEGA BLVD Suite A	90035	10	126B173   239	4303024003	C1-1, C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.04328	-118.37672	CHANGE OF USE FROM RETAIL TO BEAUTY SALON AND  BEAUTY  TRADE  SCHOOL .  TENANT IMPROVEMENT.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8674	11041-20000-03860	8349 N LAUREL CANYON BLVD	91352	6	192B165   367	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	10/05/2011 12:00:00 AM	PIN	34.22302209	-118.397629	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RETAIL STORE TI. EXISTING PANEL AND AC EQUIPMENT. PERMIT FOR NEW CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8675	17041-10001-41851	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.04443	-118.29612	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include adding additional lights in library/classrooms, and revising title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8676	15041-20002-13484	1930 S LONG BEACH AVE EAST UNIT - B	90058	9	118-5A213 351	5167013042	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.01969	-118.2427	THIS IS SUPPLEMENTAL PERMIT TO CORRECT THE SYSTEM SIZE. THIS PV SYSTEM IS PERMITTED FOR 55.2KW AC. THIS SYSTEM USES 170 MODULES. 2 INVERTERS TO A AC LOAD CENTER. THIS IS PART OF A 2 SYSTEM INSTALLATION. THIS PERMIT SHALL COVER SYSTEM 1 OF 2. THIS IS FOR UNIT B.PLAN CHECK FOR SPLIITING OF THE SYSTEM AND PERMIT FOR SYSTM B.PERMIT ISSUED FOR SEPARATION OF SYSTEM AND ALLOW INDIVIDUAL INSPECTION OF SYSTEM B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8677	19041-10000-52732	9944 N GLADE AVE	91311	12	201B101    27	2745014032	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.25127	-118.60827	NEW PV1 ROOFTOP SOLAR SYSTEM CONSIST OF 16 MODULES (CSUN 380) WITH 16 OPTIMIZERS (SE P370) AND 1 CENTRAL INVERTER (SE7600H-US). SYSTEM SIZE IS 7.6KWAC AND 6.08KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8678	14041-10000-03060	2121 S AVENUE OF THE STARS 23RD FLOOR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF CORRIDORS AND BATHROOMS ONLY. 2257 SQFT, EMERGENCY LIGHTING. HIGHRISE.  23RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8679	13041-20000-25512	13031 W JEFFERSON BLVD Suite #800	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	RENOVATION OF OFFICES. NEW CONNECTED LOAD GREATER THEN 400A. FULL PC FOR POWER AND ENERGY. COLLECTION OF FEES 93%, CHARGE REST ON FINAL (42 BRANCH CIRCUITS).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8680	14041-10000-21781	1 WORLD WAY PARK STRUC-# 101	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	33.94469	-118.39817	AT LAX PARKING STRUCTURE # 101, PROVIDING TEMPORARY POWER TO SUPPLY NEW 1600A DISTRIBUTION BOARD WHICH WILL POWER FUTURE MODULAR TRAILERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8681	14041-10000-26873	615 S MANHATTAN PL	90005	10	135B193   931	5503032012	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Apartment			09/29/2014 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.06286	-118.3105	"""0$ permit fees due to senate bill 1222 ""Installation of new roof mounted solar PV array.  180 modules, 5 combiner boxes, 4 inverters, 56  kWac."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8682	17041-10000-18335	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	Title 24 plan check only.  T.I. to 3rd floor corridor and elevator lobby spaces in existing commercial highrise building.  Subpanels to remain existing with new lighting and receptacles.  Total area = 2,860 sq. ft.       Building permit #17016-10000-00166	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8683	19041-10000-34268	16641 W OLDHAM PL	91436	5	162B137    32	2291014022	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	11/09/2019 12:00:00 AM	ADDRESS	34.14373	-118.49609	$0 fee due to AB1414. PV1, NEW ROOFTOP MOUNTED SYSETM, SYSTEM SIZE IS 14.6KWdc/10KWac. SCOPE OF WORK INCLUDES 40 MODULES (LG365Q1C) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE10000H-US), WITH AN EXISITING 400A MAIN PANEL AND A DERATE MAIN BREAKER TO 175A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8684	15041-10000-15463	1557 N LABAIG AVE	90028	13	147A189    10	5545008029	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.09913	-118.32065	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8685	10041-10000-25873	18812 W LANARK ST	91335	3	189B121   123	2103011011	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2010 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Expired	05/17/2013 12:00:00 AM	ADDRESS	34.21734	-118.54308	installation of  a 19.08KW  PHOTOVOLTAIC SYSTEM ON THE ROOF  OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8686	12041-10001-07105	8517 N VALLEY FLORES DR	91304	12	193-5A091  62	2017022022	A1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.22462	-118.64938	Modification to previously approved set of drawings to change inverters and add an additional solar-panel.               <<<<NEW ROOF MOUNTED 20.1 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8687	17041-10001-27248	1120 W WASHINGTON BLVD	90015	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	PIN	34.03794253	-118.28208997	PC FOR CHANGES TO APPROVED SET FOR FIRE ALARM. CHNGES MARKED UNDER DELTA 5. SCOPE OF CHANGES INCLUDES CHANGEING FROM SMOKE DETECTOR TO DUMPER CONTROL MONITOR PER FIRE DEPT. TOTAL OF 20 DEVICES CHANGED. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTERBuilding application number: 16010-10000-03992	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8688	16041-10001-24120	24049 S FRAMPTON AVE	90710	15	039B197    27	7439011032	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	33.80588	-118.30006	"DESIGN-BUILT: INTERIOR BLD TI TO (E) BUILDING ""A"". OUTLETS AND SUB PANELS AND TRANSFORMER FOR RECONFIGURED LAYOUT. FULL PLAN CHECK AND TITLE 24 FOR NEW ADDITION. 2568 SQ. FT.)PART OF PERMIT FEE IS PAID UNDER # 16041-40000-24120."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8689	17041-10000-44540	1238 E OLYMPIC BLVD	90021	14	123A213    49	5132006011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Issued	12/12/2017 12:00:00 AM	ADDRESS	34.03259	-118.24506	Remove HID fixtures and replace with new LED fixtures  T-24 only.TOTAL SQ.FT 7775	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8690	17041-20000-07337	10921 W WILSHIRE BLVD 912	90024	5	132B153   344	4363023032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM			PC Info Complete	03/15/2017 12:00:00 AM	ADDRESS	34.05881	-118.44477	ti to an existing medical (dental Office) in a high rise building.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8691	17041-10000-05341	700 W 7TH ST STE G640	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Issued	04/03/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC for energy T24  for TI space. Total affected area is 1423 sqft.NOTE:COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 9/13/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.CASE NUMBER: 142962%%T.I. FOR EXISTING RETAIL SPACE INCLUDING NEW PARTITIONS, MILLWORK,  NEW SUSPENDED CEILINGS, & INTERIOR ALTERATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8692	14041-10000-35225	5711 W CENTURY BLVD	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Expired	11/17/2017 12:00:00 AM	ADDRESS	33.94573	-118.38128	T24 ONLY. REMOVING EXISTING CHANDELIERS AND REPLACING WITH NEW PENDANT CHANDELIERS. TOTAL AREA 5715 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8693	09041-10004-15759	5040 S WESTERN AVE	90062	8	111B193  1307	5016036038	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM			PC Approved	01/10/2011 12:00:00 AM	ADDRESS	33.99701	-118.30867	REVISION TO THE LIGHTINGPLAN-LUMINAIRES WERE RLOCATED, REMOVE AND REPLACED. ALL CHANGES ARE CLOUDED ON THE LIGHTING PLANSPLAN CHECK POWER AND ENERGY FOR NEW ADULT DAY CARE CENTER, ADULT DAYCARE ON THE FIRST FLOOR AND OFFICE ON THE SECOND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8694	16041-20000-12141	8001 N VENTURA CANYON AVE	91402	6	189B157   306	2213019040	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.21649	-118.42885	Plan check for a PV2 carport PV system. System size is 580 kWac and consists of (19) inverters, (2,400) modules, and (2) load centers.Note: Building application has been generated under 16010-20000-01407	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8695	19041-10000-37449	6853 N WOODLEY AVE	91406	6	183B141   678	2224025014	[Q]MR1-1, [Q]P-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	05/24/2021 12:00:00 AM		Permit Finaled	12/07/2022 12:00:00 AM	ADDRESS	34.19548	-118.48388	FULL PLAN CHECK FOR  A  NEW THREE-STRORY SELF-STORAGE BUILDING WITH A NEW 1600AMP SERVICE. TOTAL AREA: 140,347 SQR FT.BULDING PERMIT: 19010-10000-03090	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8696	17041-10000-11365	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC FOR INSTALLATION OF LPG Truck loading grounding systemincludes TWO NEW BRANCH CIRCUITS IN HAZARDOUS LOCATION CLASS 1 DIV 2 ( VALERO REFINARY).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8697	18041-10002-06012	4141 W SANTA MONICA BLVD Basement-Parking	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	Replacing existing Lights in the Basement / Parking area with new LED lights. T-24 Energy Only.Affected Area: 11,825 SFTBuilding Permit:17016-10000-17688	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8698	10041-10000-25198	945 W PACIFIC COAST HWY	90744	15	036B201   757	7414035034	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	08/19/2011 12:00:00 AM	ADDRESS	33.79071	-118.27453	TENANT IMPROVEMENT; CONVERT EXISTING RADIO SHACK INTO A 7-ELEVEN;	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8699	19041-20000-42133	17310 W VEREDA DE LA MONTURA	90272	11	138B113    53	4431010011	C1-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	06/03/2021 12:00:00 AM		Permit Finaled	08/25/2023 12:00:00 AM	ADDRESS	34.07687	-118.56514	FULL PLAN CHECK FOR NEW 1600 AMP 480/277 3 PHASE SERVICE, PANELS, EQUIPMENTS AND TITLE-24. TOTAL SQUARE FOOTAGE = 96217  SFBLD# 19010-10000-01311	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8700	14041-20000-29403	6701 S CENTER DR WEST SUITE 700	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	33.97907	-118.39369	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING LIGHTING TO EXISTING POWER EQUIPMENT.  WORK TO BE DONE IN SUITE 700.   5390 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8701	12041-10000-13729	1611 N KENMORE AVE	90027	13	147B197   452	5543005014	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.10026	-118.29748	Plan check new installation of fire alarm system to an existing 2-story nursery school building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8702	14041-10000-07890	1409 S WALGROVE AVE	90291	11	114B149   683	4244003009	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			Reviewed by Supervisor	04/09/2014 12:00:00 AM	PIN	34.00767071	-118.45473846	PV1,INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US(17) MODULES: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8703	13041-10000-04818	680 S BERENDO ST	90005	10	132B197   130	5094008010	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			05/14/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.06064	-118.294	recalculate fees before permit issuance.SEE contact for contact informationPROPOSED 171 UNIT APARTMENT W/ GARAGE. 6 STORIES OF TYPEIIIA CONSTRUCTION W/ 3 LEVELS (2 BASEMENT AND 1ST FLOOR) OF TYPE I GARAGE.Parallel Design-Permitting Program 30% submittal (total submittal is 30%). Complete zoning. No life safety, no disabled access, no green, and no structural.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8704	16041-10000-43280	1566 E WASHINGTON BLVD	90021	9	118-5A213   1	5129014020	M1-1, M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.02075	-118.2442	PC for enrgy only. Title 24. Remove HID fixtures and replace with new LED fixtures. Total sqft: 4900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8705	16041-10000-33475	516 W 6TH ST	90014	14	129A209    96	5144004037	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.0482	-118.2548	PC for energy only, title 24. TI to an existing restaurant. Adding new lighting and new power equipment. Total added load is less than 400 amps. Total sqft = 2494.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8706	13041-10001-23101	181 S ALTA VISTA BLVD	90036	5	138B181  1240	5512021001	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	ADDRESS	34.07125	-118.34755	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED.  TRANSFORMER. SYSTEM SIZE:6.48 KW. 24 MODULES. SMA SB6000. PLANCHECKER CHECK THE FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8707	14041-20000-00623	9678 N NATICK AVE	91343	7	201B149   541	2650018030	RS-1	North Valley		North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.24593	-118.45386	PV1 LF TRANSFORMER 3 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8708	16041-20000-32451	15511 W HIGH KNOLL ROAD	91436	5	165B141   399	2285006023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.14652	-118.47266	Plan check for a PV1 roof-mounted PV system. System size is 10.1 kWac and consists of (30) AC modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8709	11041-10000-21639	11565 W DILLING ST	91604	2	162B169    99	2368011019	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.14335	-118.38465	New 14kva photovoltaic system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8710	17041-10000-10410	11641 N CORBIN AVE	91326	12	213B113   277	2701057900	PF-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.28132	-118.5698	PC FOR PV2 COMMERCIAL ROOFTOP SYSTEM. THIS PERMIT TO COVER INSTALLATION OF SOLAR ARRAY. PORTION OF PV WILL INTERCONNECT WITH MAIN SERVICE AND ANOTHER PORTION WILL BE CONNECTED TO BATTERY STORAGE SYSTEM WITH WILL BE COVERED UNDER SUPPLEMENTAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8711	18041-20000-03895	300 S GRAND AVE STE 2750	90071	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.05283	-118.25116	ti to an existing commercial bulding.  adding new lighting new controls to existing panels.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8712	11041-20000-14384	8321 W BEVERLY BLVD	90048	5	138B173   399	5514009024	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.07623	-118.3707	Ti in an existing office Bldg. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8713	19041-10000-51968	739 1/2 E PICO BLVD	90021	14	123A211    66	5132012055	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.03229	-118.25265	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8714	10041-10000-21650	6431 N FALLBROOK AVE	91307	12	180B097   481	2038040022	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM			Corrections Issued	01/24/2011 12:00:00 AM	ADDRESS	34.18791	-118.62609	INSTALLATION OF NEW STORAGE RACKS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8715	18041-20000-33662	19552 W LEMARSH ST	91324	12	204B117   320	2726015001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.25531	-118.55958	PV1.  Install roof mounted PV system sized 11.4 kW AC interconnected with MSP.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8716	15041-20000-39956	4849 N VAN NUYS BLVD #200	91403	4	169-5A151  98	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.15918	-118.44892	Non structural tenant improvment to the (e) medical office, scope of work includes exam rooms. Total area 1,029sq.ft. Adding new X-Ray ckt breaker 100A (10kW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8717	19041-10000-53699	1820 E INDUSTRIAL ST 2nd floor	90021	14	124-5A2171372	5164021121	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	06/02/2021 12:00:00 AM		Permit Finaled	07/08/2022 12:00:00 AM	ADDRESS	34.03563	-118.23389	The original scope of work has been greatly reduced to a new panel, lighting and few circuits. Plan check is for Title 24 Part 6 compliance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8718	13041-20000-06154	7357 W HILLROSE ST	91042	2	207B197   800	2566009029	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.20	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	34.26297	-118.29329	new rooftop pv system for an existing sfr.  system is ungrounded and has additional dc/dc converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8719	17041-20000-14126	3554 S OCEAN VIEW AVE	90066	11	114B153   470	4248024019	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.00981	-118.43647	Plan check for a PV1 roof-mounted PV system. System size is 12.5 kWac and consists of (39) PV AC modules and (1) load center.$23.16 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8720	18041-20000-48715	8600 W LA TUNA CANYON ROAD	91352	7	198B189   116	2401028***	A1-1XL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.23699	-118.3204	Plan check for PV roof mounted system, system size: 21.6kW DC, 18.3kW AC with 60 PV Modules and 2 inverters(11.4kW and 7.6kW) connected to 400A Service.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8721	14041-10000-28409	3112 W SUNSET BLVD	90026	13	142-5A203 243	5426016007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.0846	-118.2747	Energy plan check from a retail to a restaurant; note, permit to be pulled within (30) day after plan check is completed.CE investigation fee paid at time of permit issuance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8722	19041-20000-40966	3443 E WHITTIER BLVD	90023	14	121-5A227 124	5188004040	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Apartment			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.02732	-118.19955	PV2 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING APARTMENT BUILDING. SYSTEM SIZE IS 10.72 KW DC/9.112 KW AC. SCOPE OF WORK CONSISTS OF (32) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8723	13041-20000-02282	4811 S ALAMEDA ST	90058	9	111A215     3	5106008005	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM			PC Approved	01/29/2013 12:00:00 AM	ADDRESS	34.00009	-118.23903	ENERGY PLAN CHECK OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8724	12041-20000-02366	10753 N SUTTER AVE	91331	7	207B157  1310	2535030001	M2-1-O	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			Corrections Issued	02/01/2012 12:00:00 AM	ADDRESS	34.26508	-118.41994	Install new 1000 ampere exterior service on the site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8725	15041-10000-10820	11301 W OLYMPIC BLVD 104	90025	11	126B153  1060	4260002032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	PIN	34.03822251	-118.44166899	TITLE 24 FOR A COMMERCIAL BUILDING, CHANGING LIGHTING FIXTURES FROM FLOURECENT TO LED LIGHTING. TOTAL SQ. FT. 506	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8726	16041-10000-37243	5515 S COMPTON AVE	90011	9	108B209   823	5104020031	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM			Corrections Issued	10/20/2016 12:00:00 AM	ADDRESS	33.99249	-118.24796	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.6KWac.(29)MODULES-HYUNDAI HiS-S260MG MONO (1)INVERTER-PVI-3.6-OUTD-US(1)INVERTER-PVI-3.0OUTD-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8727	14041-20000-00367	10316 N GARDEN GROVE AVE	91326	12	204B125   150	2731027020	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.25783	-118.53078	PV1 STANDARD PLAN. TOTAL SYSTEM SIZE 7.5KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8728	13041-10000-23654	11150 W SANTA MONICA BLVD SUITE 200	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM			PC Approved	09/06/2013 12:00:00 AM	ADDRESS	34.04704	-118.44563	4,000 sq ft office TI on 2nd floor of highrise building.  Newly connected load less than 400A, plan check only for Title 24 compliance.  Permit to be issued by electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8729	19041-10000-10627	20701 W PLUMMER ST	91311	12	201B109   305	2748003071		North Valley	CHATSWORTH-PORTER RANCH			1133.03	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	08/11/2021 12:00:00 AM	ADDRESS	34.24287	-118.58449	PC for PV-1, Fit program. System includes 4680 Modules (LG 400n2w-A5) with 2340 solaredge optimizer (P800). 44 inverters (solaredge SE33.3Kus). 9 Sub-Panels 250A each. new 2000A switchboard.PERMIT FEE IS $0 IN ACCORDANCE WITH Ca SB1414 and SB 122	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8730	15041-10001-30252	9251 N KESTER AVE	91402	6	198B149   296	2651002029	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	34.23897	-118.45634	02/24/16CHANGES TO AN EXPRESS PERMIT FOR A 35AMP PV FEED BACK BREAKER. PC ONLY, INSPECTION FEES WERE PAID UNDER MASTER APPLICATION # 15041-90000-30252.NOTE: ZONING IS CHECKED ON ORIGINAL PERMIT. (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8731	13041-10000-29486	5334 N OVERING DR	91367	3	171B089   136	2047018016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Expired	12/21/2015 12:00:00 AM	ADDRESS	34.16722	-118.64765	PV1.  $0 permit fee is due to the 2012 Senate Bill No. 1222. Install 13.75 kW DC roof-moutned photovoltaic system interconnect with main service panel. Fronius IG Plus A 7.5, Fronius IG 4000 NEG inverters, and Trina TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8732	14041-20002-03304	8211 W 3RD ST	90048	5	138B173   830	5511019034	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.07264	-118.36846	changes made to previously approved set , to be clouded ane recalculate title 24,  corrections on the plans.  medi zandi 4-4-14.600A SERVICE UPGRADE AND NEW LOAD FOR CHANGE OF USE TO HAIR SALON. PLAN CHECK FOR POWER AND ENERGY. PLAN CHECK IN ACCORDANCE TO 2008 NEC PER BUILDING SUBMITTAL)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8733	17041-20000-43975	6038 N JUMILLA AVE	91367	3	177B117   572	2153021013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			Reviewed by Supervisor	12/28/2017 12:00:00 AM	ADDRESS	34.18041	-118.56352	PV1.  Install 10.03 kW roof mounted grid tied PV system.  (34) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8734	14041-10000-30537	725 S FIGUEROA ST 1ST FL.	90017	14	129A207    14	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.04886	-118.26071	INTERIOR T.I. -  REMODEL OF (E) BANK PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8735	18041-10001-34660	6150 N LAUREL CANYON BLVD BLDG J	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	11/16/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	SUPPLEMENT INSTALLATION OF 1 FACP AND 24 DEVICES FOR ATRUIM SMOKE CONTROL FOR BUILDING J.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8736	12041-20000-28865	8489 W CRESCENT DR	90046	5	153B169   725	5563011022	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	ADDRESS	34.11326	-118.38059	New rooftop mounted photovoltaic system for an existing single family residence.  System uses High-Voltage THIN FILM Modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8737	16041-20001-05620	18649 W CALAHAN ST	91324	12	198B121   702	2763012020	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	34.23653	-118.53989	Expedite per applicant request.{{{{{{Plan check for PV roof mounted system. System size: 12.0kW with 38 modules and 2 inverters(5.0kW and 7.0kW) connected to 100A sub-panel.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8738	17041-10000-32220	355 S GRAND AVE LEVELS-5, 6, 7	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	T-24, PC FOR ENERGY ONLY. INTERIOR OFFICE T.I. TO AN EXISTING OFFICE TENANT SPACE ON LEVELS 5,6, AND 7. TOTAL AFFECTED AREA IS 3119 SQ. FT. B#17016-10000-26056	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8739	13041-20001-23656	1585 W OAKHORNE DR	90710	15	042B193   153	7438003013	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	33.81338	-118.30556	PV1 MICROINVERTER. TOTAL SYSTEM SIZE 2.36KWAC. 11 MODULES AND 11 MICROINVERTERS((recheck for lost set of plans. this permit still valid.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8740	17041-20001-40409	550 S HOPE ST ste 1950	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	plan check for changes to approved set of plans for lighting layoutti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8741	15041-10000-36040	111 E UNIVERSAL HOLLYWOOD DR 30TH FLR	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	T-24, TI TO THE 30TH FLOOR IN AN (E) HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTACLES. TOTAL SQ. FT. 20420.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8742	12041-10000-13813	4557 N LONGRIDGE AVE	91423	5	168B157   810	2360026037	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.15378	-118.42154	installation of a photovoltaic system on the roof of a SFD; PV system consists of solar modules, an inverter and wiring	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8743	18041-20000-42803	599 W AVENUE 28	90065	1	144A219   387	5446007025	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			11/07/2018 12:00:00 AM			Reviewed by Supervisor	12/04/2018 12:00:00 AM	ADDRESS	34.0869	-118.22338	Plan check for power only for lot sub division 10 individual homes 1000A 120/240 1 phase feed 10 individual homes. Building  permit has been issued 10 individual permit under single address Unit 1,2,3,4,5,6,7,8,9,10. 15010-20000-04536	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8744	12041-20000-29215	9105 W HAZEN DR	90210	5	153B165    74	4388020014	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.11815	-118.39566	change feeders from coppers to aluminum and add generator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8745	17041-20000-22680	3660 W WILSHIRE BLVD	90010	10	132B193    63	5093019020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Issued	01/09/2018 12:00:00 AM	ADDRESS	34.06155	-118.30505	Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,052) modules, and (1) load center.Note: Permit Fees $0 due to SB 1222Note: Building application has been generated under 17014-30000-03171	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8746	18041-10000-17514	1942 W 1ST ST	90732	15	018B189   267	7559012023	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	09/25/2023 12:00:00 AM	ADDRESS	33.74306	-118.31845	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. CONISIT OF 18 AC MODULES(SPR-X22-360-D-AC) . SYSTEM SIZE IS 6.48KWdc AND 5.76KWac. SCOPE INCLUDES NEW BACKUP PANEL (200A) AND A COMBINER BOX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8747	17041-20000-05550	11538 W CHIQUITA ST	91604	2	162B169    39	2368011012	RE11-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.14442	-118.3837	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (42) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8748	13041-10000-31725	4645 N VAN NUYS BLVD SUITE #202	91403	4	168A151    62	2265012015	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.15597	-118.44889	PLAN CHECK FOR T24 ENERGY ONLY. 2ND FLOOR OFFICE SUITE #202. 1876 SQFT, NO EMERGENCY REQUIRED ACCORDING TO APPLICANT. NO CHANGE IN OCCUPANCY. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8749	19041-20000-20992	14931 W CALIFA ST Ste 201	91411	4	177A149   141	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.17768	-118.4586	Power and lighting for 2nd floor office TI.  New distribution and loads exceeding 400A.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8750	16041-20000-24967	10945 N NESTLE AVE	91326	12	210B125   627	2715017035	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.26937	-118.53076	Plan check for PV roof mounted system. System size: 6.0kW with 30 modules and 1 inverter(6.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8751	17041-10000-05781	8231 W 3RD ST	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.07272	-118.36914	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE. SCOPE INCLUDE NEW LIGHTS. TOTAL AFFECTED AREA IS 3869 SQ. FT.  b#16016-10000-30248	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8752	10041-10004-11574	7045 W LANEWOOD AVE	90028	13	147B181   419	5548012009	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.09933	-118.34304	SUPPL. APPLICATION TO MODIFY THE APPROVED PLANS. DUE TO THE LOCATION OF THE UTILITY TRANSFORMER THE CONFIGURATION OF THE SERVICE EQUIPMENT WAS CHANGED. <<<Plan check power and energy for new 4-story 43 unit apartment building. Modification to seperate fire alarm system has been filed>>>.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8753	16041-30000-19348	5667 W OLYMPIC BLVD	90036	4	132B181   632	5089026036	[Q]R3-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Issued	06/07/2016 12:00:00 AM	ADDRESS	34.05754	-118.35309	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,175 sq. ft.Note: Building permit has been issued under 16016-30000-08051	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8754	16041-30000-35929	5301 W 8TH ST	90036	4	132B181   220	5089001010	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM			Reviewed by Supervisor	11/10/2016 12:00:00 AM	ADDRESS	34.06064	-118.34494	Installation of new roof mounted solar PV array on existing two story commercial building.  43 new modules with 1 new ABB UNO-8.6-TL inverter and 1 new ABB PVI-5000 inverter. Total system size = 13.6 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8755	13041-10000-25740	505 S VIRGIL AVE ste 102	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.0649	-118.28724	TITLE-24 ONLY; WORK IS FOR INTERIOR TENANT IMPROVEMENT FOR DOCTOR'S OFFICE. NO SURGICAL OPERATION WILL BE DONE IN THE DOCTOR'S OFFICE PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8756	15041-20003-31204	21440 W VILLENA AVE	91364	3	168B105   623	2171002022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.15611	-118.59793	12/16/15Changes to an approved set. PC for derated of the main breaker and loads ((((PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(23) Hanwha G3-270W Modules(1) Solar Edge SE6000 Inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8757	14041-20000-35550	19800 W DEVONSHIRE ST	91311	12	204B113   213	2726008001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.25704	-118.56565	PC FOR FACP REPLACEMENT. LIKE FOR LIKE. RECHECK BATTERY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8758	19041-10000-18362	801 E E ST	90744	15	030B209   741	7424014021	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	33.77626	-118.25281	Plan check for a methane detecting system located in a (2) story commercial building. Scope inlcudes (1) control panel, (1) power supply, and (29) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8759	16041-10003-25329	1309 W SEPULVEDA BLVD	90501	15	045B197   144	7347018094	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Closed	03/18/2019 12:00:00 AM	ADDRESS	33.81485	-118.29961	REVISION TO APPROVED SET . ORIG # 16041-10000-25329. SCOPE INCLUDE INSTALLING 60A PANEL ADDING HVAC UNITS, LTGS AND PWR IN COMMUNITY ROOM. CHANGE UNDER DELTA 1ORIGINAL PROJ DESCRIPTION: PC FOR POWER AND ENERGY. NEW SIX STORY, 176 UNITS APARTMENT BUILDING. 6 TYPES APARTMENT WITH THE SAME PANEL TYPE. SCOPE OF LIGHTING INCLUDES OUTDOOR AND INDOOR: 150318 SQ FT.B# 15010-10000-00532	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8760	19041-10000-48519	3730 N WOODCLIFF ROAD	91403	4	162A145   122	2279003010	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			Reviewed by Supervisor	12/17/2019 12:00:00 AM	ADDRESS	34.13809	-118.46756	VOID***** APPLICANT RECEIVED SEPARATE PLAN CHECK AND PERMIT UNDER 19041-20000-51523(E-PLAN)NEW INSTALLATION FOR AN EXISTING SOLAR SYSTEM. INSTALLALTION INCLUDES 1 PANEL OF 125 AMPS, 1 PANEL OF 225 AMPS, AND 3 ENERGY STORAGE SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8761	12041-10000-27966	380 W WORLD WAY GATE 148	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Wiring and equipment installation for end-use equipment to serve(1) Passenger Boarding Bridge(s) (PBB) for TBIT  Core gate 148Similar submittal for other gates was approved/permitted on 11041-10000-24507	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8762	16041-10001-02487	3900 W 6TH ST	90005	10	135B193   885	5503030001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Issued	10/22/2018 12:00:00 AM	PIN	34.06325314	-118.30807759	MAJOR CHANGES ( DELTA 2 ) TO APPROVED PLANS.<<<<<<<PC FOR POWER AND ENERGY. TI FOR RESTURANT. NO CHANGE OF USE, 2-STORY WITH ONE LEVEL BASEMENT, SMT LA RESTURANT. ADDING 6 NEW 200A PANELS AND TWO 45 KVA TRANSFORMER  TOTAL AREA 13660 SQ (INDOOR AND OUTDOOR).>>>>>B# 15016-10000-25358	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8763	19041-20000-01347	6255 W SUNSET BLVD 1050	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.this is plan check only.permit fees paid under application number 19041-90000-00435	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8764	15041-20000-30859	3641 S WATT WAY 5th Floor	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.02033	-118.28801	PC for energy only. TI to an existing USC laboratory 5th floor.  New panel for all receptacles, new light fixtures. Total area: 1131 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8765	15041-20000-16516	8758 N GLORIA AVE	91343	12	195B141   580	2672022006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.22994	-118.48059	pv1 sfd. total system size 6kw ac using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8766	12041-10000-08724	2033 E IMPERIAL HWY	90059	15	084B213   111	6067013006	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	33.9294	-118.2351	New 3.2kw photovoltaic system for the rooftop of an existing 10-unit, multi-family building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8767	14041-10000-18981	8746 N CANBY AVE	91325	12	195B125   699	2769025023	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.23002	-118.53466	Plan check for fire alarm only.  Total system size = 112 devices.Fire alarm system with central station monitoring in commercial building renovated due to fire damage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8768	19041-20000-06344	6067 W WILSHIRE BLVD pv3	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	Plan check for a PV2 roof-mounted PV system. System size is 72.7 kWdc/63 kWac and consists of (3) inverters, (202) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8769	17041-20000-34186	1000 W WILSHIRE BLVD Suite 1100	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Issued	09/22/2017 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,861 sq. ft.Note: Building permit has been issued under 17016-10000-23143	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8770	14041-10000-07222	551 E COLEMAN AVE	90042	14	148-5A231  45	5301012027	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.10266	-118.18412	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN FOR CENTRAL TRANSFORMERLESS INVER SYSTEM. SYSTEM SIZE: 6.5 KW.(26) CANADIAN SOLAR # CS6P-250(1) POWER ONE # AURORA PVI 6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8771	15041-10001-10686	13155 W HARTSOOK ST	91423	4	171B157   686	2358001002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	ADDRESS	34.16408	-118.41994	EXPEDITED APPLICATION PER APPLICANT REQUEST. (PV1 ROOF MOUNTED, ONE FLOOR RESIDENTUAL. SIZE OF INVERTER 1, 5K SIZE OF INVERTER 2, 3K. AND 24 MODULES.  TOTAL 7.85KW -DC.  SUBMITTAL PER APPLICANT.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8772	16041-10000-11390	1001 S ALVARADO ST	90006	1	130-5A203 191	5136013026	C2-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.05167	-118.28012	PC for energy only to a single story retail building, boba shop. Adding 3 new panels, newly connected load is less than 400 A. Adding new lighting and receptacles. Total sq ft = 1411CODE ENFORCEMENT FEE COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 04/24/2014. CASE # 579165.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8773	13041-20000-28275	12212 N STEWARTON DR PV1	91326	12	219B121   268	2820018041	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Expired	11/16/2015 12:00:00 AM	ADDRESS	34.29423	-118.54458	Plan check only for change to system.  INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 5.39kw.  System is Ungrounded.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8774	16041-20000-17332	14931 W DELANO ST	91411	6	178-5A149 229	2242023010	C2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	05/31/2016 12:00:00 AM	ADDRESS	34.18271	-118.45864	Plan check Title 24 only in existing wearhouse. Total area: 4054 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8775	11041-10000-12688	333 S GRAND AVE 32ND FL	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Expired	07/12/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	REPLACING NEARLY ALL THE LUMINAIRES ON THE 32ND FLOOR OF AN OFFICE BUILDING; SWITCHES WILL REMAIN THE SAME; OCCUPANCY SENSORS ARE THROUGHOUT THE AREA.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8776	17041-10000-21750	4905 W HOLLYWOOD BLVD	90027	4	147B197   191	5589038051	C2-1D	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.10198	-118.29645	PC FOR FA IN A COMMERCIAL BUILDING (SINGLE STORY WITH UNDERGROUND PARKING).SYSTEM INCLUDES 3 PANELS AND 112 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8777	15041-10000-20754	1900 S AVENUE OF THE STARS LEVEL A	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI TO AN EXISITNG RESTROOM IN A COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 344.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8778	15041-20000-02515	915 W WILSHIRE BLVD 8TH FLR	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI TO AN EXISTING HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN THE 8TH FLOOR.  TOTAL SQUARE FOOTAGE 10,526	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8779	16041-10000-36648	11220 S HINDRY AVE	90045	11	087B173   101	4129038019	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	33.93221	-118.37223	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING  ROCK CLIMBING FACILITY, YOGA, GYMNASIUM BUILDING. SCOPE INCLUDES 34 FA DEVICES AND 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8780	18041-10000-18567	576 N ERSKINE DR	90272	11	126B125   359	4413018010	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.04282	-118.53349	PC FOR ENERGY STORANGE SYSTEM IN A SFD WITH EXISTING PV. SCOPE INCLUDE INSTALLING NEW POWER WALLL AND LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8781	12041-10001-19628	12661 W GAIN ST PV-1	91331	7	207B161    42	2536014016	RS-1	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.26694	-118.40928	INSTALL PHOTOVOLTAIC 8.5. AC CEC ON EXISTING ROOF. (RESIDENTIAL)  Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8782	17041-20000-15066	2949 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.03799	-118.20329	pv2install roof mounted pv system sized 1.7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8783	15041-20001-16297	936 S OLIVE ST UNIT 250	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #10 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8784	14041-10000-34469	9655 N IRONDALE AVE	91311	12	201B109   232	2748023058	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.2458	-118.58609	T24, REMOVE EXISTING LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3723 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8785	13041-20000-21601	21650 W OXNARD ST STE 1600	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM	08/12/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for energy only. Addition of partitions and relocated lights. Commercial high rise. Suite 1600, 16th Floor. Beecher Carlson.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8786	15041-10002-27170	426 E 58TH ST	90011	9	108B205  1058	5101006006	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	33.98972	-118.26645	** Changes to approved set under Delta-6: Add branch circuits, and remove Refer Rack (on roof).*FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 1000A 480/277 3 PHASE 4 WIRE SERVICE/MAIN DISTRIBUTION BOARD FOR AN EXISTING WAREHOUSE TO  JUICE COMMISSERY MANUFACTURING BUILDING. TOTAL AFFECTED AREA IS 5452 SQ. FT.NOTE: PERMIT PAID UNDER PCIS#15041-10000-27170	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8787	14041-20000-16723	1601 N VINE ST	90028	13	148-5A187 301	5546009906	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	Plan check for power and energy. energy plan check in accordance to 2008 T24 regulations. non hazardous location. 8 STORY SHELL OFFICE BUILDING WITH 5 LEVELS OF BELOW GRADE PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8788	12041-10000-04727	2080 N HILLHURST AVE	90027	4	150B201   302	5590008036	C4-1D	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.10975	-118.28727	PLAN CHECK T24 ENERGY/EMERGENCY FOR HEALTH FOOD STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8789	19041-20000-44864	3522 N GRIFFITH PARK BLVD	90027	4	154-5A203 334	5592002012	R1-1	Central	Hollywood	Los Feliz		1882.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.11594	-118.27509	Plan check for PV and energy storage system, PV system size: 17.01KW with 54 PV Moduels and 2 inverters(7.6KW) 2 sub-panels and 2 energy storage(13.5KWh) Total energy storage system size: 27KWh.$0 permit fee per State Senate Bill SB 1222 and Assembly BIll AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8790	15041-20001-43400	7228 N AMIGO AVE	91335	3	183B121  1185	2118028063	(T)(Q)R3-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			01/15/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	34.20195	-118.53846	Expedite per applicant request{{{{{Plan check for PV roof mounted system for Appartment building. System size: 10kWac and 32 modules and 2 inverters(5.0kW and 5.0kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8791	19041-10000-22150	3420 N GREEN VISTA DR	91436	5	159B137   330	2287010064	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.1326	-118.4988	Plan check for a PV1 7.6KW AC / 6.4KW DC roofmounted system with (1) battery storage system, (1) load center, (1) inverter, (21) modules and optimizers interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8792	14041-10004-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			07/31/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	DELTA 13 CHANGES TO THE APPROVED PLANS. SERVICE LOAD CALCULATION BEING UPDTED DUE TO NEW CKTS  ADDED TO OTHER  PANELS, TRANSFORMERS AND PANELS ADDED FOR (5) RETAIL SPACE. NEW ELECTRICAL ROOMS ALSO BEING ADDED.<<<<<PLANCHECK FOR POWER AND ENERGY FOR  A  NEW 472 Unit Type III  Apt. Building Over Type I Commerciasl Use & Garage Structure. TITLE 24 ENERGY SQFT NOT INCLUDED IN FEES. FEES ARE BASED APPLICANT.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8793	17041-20000-07516	11135 W BURBANK BLVD	91601	2	174B173   874	2337031036	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.17237	-118.37358	Plan check for a fire alarm system for a new hotel. Fire alarm consist of (1) FACP, (2) annunciators, and (181) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8794	16041-10000-45776	380-382 WORLD WAY NBHS	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for power and Title 24.  Provide normal and emergency power to North Baggage Building in LAX.Building permit #16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8795	19041-10000-18660	735 S FIGUEROA ST #139	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	ADDRESS	34.04878	-118.26079	T-24, Pc for energy only. Scope includes new lights and receptacles for an existing T-Mobile retail store. Total affected area is 815 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8796	16041-20000-35160	9350 N DE SOTO AVE	91311	12	198B109    80	2748002071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.2406	-118.58834	PV2 ROOFMOUNTED (172 KW)  AND  ( GROUNDMOUNTED SYSTEM  + EV CHARGERS ON SAME PLANS[ PLANCHECK # 16041-20000-35160 ) ON SAME PLANS. FEES FOR GROUNDMOUNTED SYSTEM AND EV CHARGERS ONLY ( 2 OF 2 )SYSTEM SIZE: 398 KW DC. (1156) SW 345 MODULES(2) 23 KW SOLECTRIA PVI(4) 28 KW SOLECTRIA PVI(5) 36 KW SOLECTRIA PVI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8797	11041-20005-03572	340 S MAIN ST	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.00	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	33.99519	-118.47673	Revisions to an approved set of plans.  Adding a new panel for electric vehicle charging stations.  <<<<<<<<Tenant improvements to all three floor including new exterior and interior openings, new restrooms, caf� and kitchen, new offices, pantries, and conference rooms.>>>>>>>>>>	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8798	14041-20001-10997	13548 W PIERCE ST	91331	7	204B157   558	2646022006	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.25649	-118.42783	Expedite per customer requestPV1. 3.9kw roof-mounted system with (1)Sunpower inverter tranformerless PVI -3.8-OUTD- US and (12)SPR-327NE modules interconnected with main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8799	14041-20001-32534	14614 W DEERVALE PL	91403	4	162B149   458	2275022008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			PC Approved	12/12/2014 12:00:00 AM	ADDRESS	34.1384	-118.45295	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NEGATIVELY GROUNDED NON STANDARD PLAN. SYSTEM SIZE: 15.3 KW DC. (60) KYOCERA # KD255 GX(1) FRONIUS IG 11.4 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8800	16041-10000-06104	3228 W WELDON AVE	90065	13	156B213   253	5459010019	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.01	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.1222	-118.24147	PV1. NEW SOLAR SYSTEM TO AN EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.9KWdc / 3.225KWac.(15)MODULES-HYUNDAI HiS-S260RG(15)MICROINVERTERS-ENPHASE M215-60-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8801	16041-20000-17926	1304 N HIGHLAND AVE	90028	4	144B185    87	5547033400	C2-1-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.0947	-118.3384	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT FAT SAL'S.  1184 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8802	12041-20000-19827	19500 W RUNNYMEDE ST	91335	3	186B117   998	2116020001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.20578	-118.55811	Photovoltaic system on roof of single family dwelling and one circuit for a PV monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8803	14041-10000-27470	663 N LA FAYETTE PARK PL	90026	13	139-5A203  45	5402005002	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/27/2014 12:00:00 AM	ADDRESS	34.07806	-118.27393	PV1, INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(6) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB # PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8804	13041-20000-29882	5250 N LANKERSHIM BLVD 1st FLOOR	91601		171B173   367	2350018086							Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.16668	-118.37545	T24 FOR EXISTING HIGHRISE SCHOOL. SCOPE OF WORK ON THE 1st FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8805	11041-10000-22389	5250 N LANKERSHIM BLVD	91601		171B173   367	2350018086							Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM			PC Approved	10/19/2011 12:00:00 AM	ADDRESS	34.16668	-118.37545	T.I. to an existing office space.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8806	16041-20000-13752	2707 E 4TH ST	90033	14	126A225   189	5180013026	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM			Corrections Issued	04/20/2016 12:00:00 AM	ADDRESS	34.03893	-118.20764	Install a roof-mounted solar array on the commercial portion of a store-and-residential-combination building.System size: 2.15kW. Ungrounded system. (10) EnPhase M215 microinverters(10) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8807	16041-20001-44059	8400 N BELLINGHAM AVE	91352	6	192B165   361	2633004009	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM			PC Approved	12/30/2016 12:00:00 AM	ADDRESS	34.22304	-118.39911	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8808	11041-20000-00546	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	06/02/2011 12:00:00 AM	ADDRESS	33.76597	-118.28407	Plan check power and energy for office TI. Existing service. New panels, circuits installed, and relocate panels, and transformer. Lighting on existing ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8809	15041-20000-00800	17044 W OAK VIEW DR	91436	5	165B133   136	2292001040	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.15106	-118.50535	$0 premit fee due to senate bill 1222 from 2012PV1Install a roof-mounted array on a SFD. Interconnect with a 400A MSP (?).System size: 16.4kW (11.4+5). Grounded system. 56  327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8810	19041-20000-39283	8724 N REMMET AVE	91304	3	195B105   208	2779041017	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM			PC Info Complete	11/27/2019 12:00:00 AM	ADDRESS	34.22893	-118.60011	POWER AND ENERGY PLAN CHECK ONLY. T24 INCLUDED. SCOPE OF WORK INCLUDES CONNECTION TO PREVIOUSLY APPROVED SERVICE, NEW LIGHTING AND CIRCUITS. TOTAL SQUARE FOOTAGE = 6128 SFSERVICE EQUIPMENTS HAVE BEEN PULLED UNDER 19041-20000-17390	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8811	10041-20001-10022	916 S MAIN ST	90291	11	109-5A143 472	4286013031	C2-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM			PC Approved	07/22/2010 12:00:00 AM	ADDRESS	33.99203	-118.47369	"""Plan check only"" Supplemental plan check for lost approved plans.  Plans under T-24 2005 compliance forms, plan check under 2008 T-24 compliance.  Permit under #10041-90000-05041"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8812	14041-20000-00210	13027 W VENTURA BLVD	91604	2	165B161   952	2375020018	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM			Reviewed by Supervisor	01/24/2014 12:00:00 AM	ADDRESS	34.14582	-118.41697	T. I. AND CHG OF USE FROM RETAIL TO TAKE-OUT RESTAURANT(((pc for t24 and power. full plan check 600A service upgrade))))  permit was puulled under 130412000033386	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8813	14041-20000-23727	1326 W ROLLAND CURTIS PL	90062	8	117B193  1041	5036014032	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.01633	-118.301	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(20) HYUNDAI HEAVY INDUSTRIES 250WATTS MODULE(20) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8814	18041-10000-03610	12445 W MOUNTAINGATE DR	90049	11	150B137     1	4490024009	[Q]A1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.1074	-118.48784	ALTERATIONS IN RESTROOMS AND LOCKERS AT COUNTRY CLUBREPLACE LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8815	18041-20000-15456	625 S ST ANDREWS PL	90005	10	135B193   973	5504028187	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.06262	-118.31173	Tenant improvement of (E) classrooms.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8816	15041-10000-06000	12638 W SATICOY ST SOUTH	91605	2	186B161   510	2324002007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.20531	-118.40857	IN AN EXISTING WAREHOUSE, REPLACING HID LUMINAUIRESWITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8817	10041-10000-01701	1091 S BROXTON AVE	90024	5	132B149    82	4363024001	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM	04/26/2010 12:00:00 AM		Permit Finaled	06/17/2010 12:00:00 AM	ADDRESS	34.06093	-118.44598	T.I.   NEW  MORNING PREP KITCHEN,  EXISTING KITCHEN REMODELING,  REMOVAL OF MEZZANINE STAIR,  RESTROOM RELOCATIONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8818	18041-10000-33870	400 S ALAMEDA ST	90013	14	127-5A215 303	5163026001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			Verifications in Progress	10/29/2018 12:00:00 AM	ADDRESS	34.04317	-118.23794	FULL PC FOR POWER AND ENERGY. CHANGE OF UESE OF EXISTING 3-STORY URM FACTORY WAREHOUSE BUILDING TO HOTEL AND RESTUARANT BUILDING. SCOPE INCLUDES A NEW 2000A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 40708 SQ. FT. B#17014-10000-05459	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8819	19041-20000-12897	626 E COLEMAN AVE	90042	14	148-5A231 122	5301020005	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Hermon	YES	2013.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/01/2019 12:00:00 AM	ADDRESS	34.1021	-118.18273	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 5.61KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (17) 330W PANASONIC PV MODULES WITH SE P400 OPTIMIZERS, (1) SE3800 INVERTER WITH EV CHARGER, AND (1) SE3800 INVERTER W/ INTEGRATED BATTERY BACKUP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8820	14041-10001-19665	7751 W BEVERLY BLVD	90036	5	138B177   431	5527039001	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.07628	-118.3586	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE NEW 600A SERVICE AND ORIENTATION OF SERVICE EQUIPMENT. ALL CHANGES CLOUDED DELTA 5 REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8821	13041-20000-06181	933 N LA BREA AVE 3rd flr	90046	5	144B181   679	5531016022	M1-2D	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM			PC Approved	03/11/2013 12:00:00 AM	PIN	34.08817379	-118.34466503	Change to lighting in an existing office space - 4-story.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8822	14041-10000-22095	5744 S BRYNHURST AVE	90043	8	108B185   821	5006003016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM			Verifications in Progress	08/27/2014 12:00:00 AM	ADDRESS	33.98954	-118.33317	plan check only. Greater than 50% design change from 14041-10000-12479.PV1 5.72KWdc. 120V. negative GND. NONstd. Battery System.  1story. Roofmount. [(1) inverters: {OUTBACK gvfx3648 with Outback power IBR-3-48-175}]. [(22)modules: {SunEdison F260}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8823	17041-30001-31698	10497 W WILSHIRE BLVD	90024	5	135B153   380	4360029250	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.06468	-118.4322	Plan check for Title 24 only in existing space multipurpose room lighting and receptacles. Total area: 3928 sq ft. Plan check onlyNote: Permit was pulled under 17041-70000-31698	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8824	18041-10005-04909	501 N SOTO ST	90033	14	129A225   101	5175009029	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.04865	-118.20687	Recheck & stamp a copy of the lost approved plans. SYSTEM DESIGN HAS BEEN ALTERED.  (((Plan check for a PV2 roof-mounted Pv system. System size is  11.4 kWac/15.0 kWdc and consists of (1) inverter and (50) modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8825	12041-20000-17794	500 S VIRGIL AVE #202	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	T.I. to existing medical space on 2nd floor (Suite 202).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8826	10041-10000-14662	2201 S LINCOLN BLVD	90291	11	108B149   307	4241034001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	33.99481	-118.45469	CORE AND SHELL FOR A MIX USE BUILDING. NEW 800 SERVIVE, PANEL AND DISTRIBUTION BOARD. PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8827	11041-10000-13142	960-968 E ELKLAND PL BLDG 1	90291	11	111B145   999	4243004036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/15/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99855	-118.45949	REPAIRS & HISTORICAL REHABILITATION  / TI OF 17 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8828	14041-20000-20236	8120 N JASON AVE	91304	12	189B093    48	2020021014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.21782	-118.63511	New roof mounted PV system with Optimizers and trasformerless inverters,  Total system size 11.98KW.Note: Permit is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8829	14041-10000-03171	11831 S JUNIETTE ST	90230	11	105B165   207	4220003043	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Expired	02/24/2016 12:00:00 AM	PIN	33.98657022	-118.40307733	CHANGES TO (E) PV SYSTEM 13041-10000-21096: changed layout of roof plan but number of modules stayed the same. Module type changed ET-P660255WB. Now PV1 3.5KWdc. 240V. microinverter. STD. 1story. Roofmount. [(14) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(14)modules: {ET-P660255WB}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8830	18041-10000-37703	5031 N BODA PL	91367	3	171B093   676	2047003011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.16259	-118.64159	NEW ROOF MOUNTED 7.59 KW PV SYSTEM WITH 23 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8831	14041-20001-25139	19346 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.23298	-118.55494	[ 1/22/15 CHANGES TO APPROVED SET PER INSPECTORS REQUEST. DELTA 2 CHANGES TO LIGHTING ONLY, CHANGE OF MANUFACTURERS FOR LEDS AND REPLACING METAL HALIDE TO LED FOR DIMMABILITY].New tenant improvement to existing currently undeveloped suite at existing building for medical urgent care office. Not high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8832	17041-10000-01862	1902 W PARK AVE	90026	13	139-5A207 209	5404002030	R3-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1957.20	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.07616	-118.26168	Permit fee is $0.00 due to Senate Bill 1222.PV2 roof mounted installaton to Park View Senior Living (commercial), (224) Solar modueles, (2) Central inverters rated at 28 KW each for a total system size of 56KW, load center rated at 100 amps..	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8833	18041-30001-11232	10351 W SANTA MONICA BLVD	90025	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM			PC Approved	04/05/2018 12:00:00 AM	ADDRESS	34.05844	-118.42319	04/05/2018 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a partial change of use from restaurant to health club/tenant improvement. Total lighting area = 2,422 sq. ft.Note: Building permit has been issued under 17016-10000-36241*****Previous Work Description*****NEW BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8834	17041-10000-27990	12121 W BLUFF CREEK DR 4th Floor	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	33.97874	-118.40463	PC for power and energy for 4th floor office. TI. Total load exceeds 400A. Total squarefootage 37869. Installing new circuits nine existing panels. Building #17016-10000-22510	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8835	11041-10000-19863	9620 N PINE ORCHARD ST	91331	6	201B161   969	2624013033	RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	34.24443	-118.4088	NEW FIRE ALARM SYSTEM FOR A NEW SINGLE STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8836	16041-10000-32933	3546 E 15TH ST	90023	14	117A227    44	5192007010	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.01576	-118.20121	FIRE REPAIR OF BUILDING. PC FOR POWER AND ENERGY. LOAD GREATER THAN 400A. PROVIDING NEW REPLACE, EQUIPMENT AND LIGHITNG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8837	14041-20000-28825	1023 W SEPULVEDA ST	90731	15	018B197   629	7452005017	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	33.74552	-118.29943	INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(20) SUNMODULES SW 275 MODULES(20) ENPHASE M250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8838	19041-10001-31189	3660 W WILSHIRE BLVD	90010	10	132B193    63	5093019020	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Approved	11/08/2019 12:00:00 AM	ADDRESS	34.06155	-118.30505	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. SCOPE OF WORK IS REVISING LIGHTING LAYOUT TO MATCH SITE CONDITIONS, T24 FORMS HAVE BEEN UPDATED PROPERLY.ALL CHNAGES ARE CLOUDED UNDER DELTA 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8839	19041-20000-29131	5901 W CENTURY BLVD ste 650	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	ti to an exisitng commercial building (high rise) adding new lighting new controls to existing panels.  plan check fot indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8840	16041-10001-06388	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	03-31-2017 Changes to an approved se to plans Nordstrom Store at Century City Mall. Changes include deleted lighting fixtures and added new lighting fixtures, revision to Titel 24 forms (Performance Method), revision to lighting and power floor plan, revision to panel panel scheduel. Changes apply to clouded area only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8841	14041-20001-29388	7317 N SEPULVEDA BLVD	91406	6	186B145   698	2222021004	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Apartment			10/23/2014 12:00:00 AM			PC Approved	12/18/2014 12:00:00 AM	PIN	34.20349842	-118.4668069	EXPEDITE PER APPLICANT REQUEST[PV2Install roof-mounted solar array on existing apartment building. System size: 22.8kW (11.4+11.4). Inverters have transformers. 88 305W pv modules. 4 strings of 11 modules per inverter. Interconnect with existing 600A MSP.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8842	19041-30000-06912	11812 W SAN VICENTE BLVD #250	90049	11	129B145   113	4265018016	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.0528	-118.4684	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 2,829 sq. ft.Note: Building permit has been issued under 19016-40000-04787	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8843	11041-20001-00529	2800 W RIVERSIDE DR	90039	4	151-5A207  93	5438025011	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.10921	-118.26198	Plan check for revision to approved plans. Revision to point of connection from supply side to load side and module type from 230W to 235W.  Derate main overcurrent protection from 400A to 200A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8844	10041-10000-16353	2101 E PACIFIC COAST HWY HTU-1	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	33.79173	-118.23549	Install a new 60 Amp Circuit for a Pre-Fabricated Gas Analyzimg equipment in a Class I Div 2 of the HTU-1 of Tesoro refinary.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8845	12041-10000-30584	735 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	TENANT IMPROVEMENT. NEW 1600 AMP SERVICE, ADDITION OF 1600 A SWITCHBOARD,  AND BUS DUCT. THERE IS NO LOAD CONNECTED TO THE BOARD. FUTURE TENANT WILL PULL THE PERMIT FOR THEIR WORK. ONLY CONDUIT FOR ONE FUTURE TENANT WILL PROVIDED. (ONE 45 X-FORMER WITH ALL DISCONNECT AND FEEDERS MOVE TO A NEW LOCATION WHICH WILL MAINTAIN ALL THE X-FORMER DISCONNECT AND TAP LENGHT REQUIMENT.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8846	11041-20000-14811	11520 W PICO BLVD	90064	11	123B153   497	4260034008	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	07/15/2011 12:00:00 AM	ADDRESS	34.0331	-118.4425	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8847	10041-20000-12643	13550 W PAXTON ST	91331	7	210B157   162	2535002014		North Valley				1043.20	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	06/08/2011 12:00:00 AM	ADDRESS	34.27276	-118.42714	Plan check for new installation 585KW Bi-Polar Photovoltaic sytem. Costco Pacoima	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8848	15041-20000-13422	20608 W LULL ST	91306	3	186B109   180	2108025051	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.20907	-118.58233	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (8) modules, and (1) inverter. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8849	17041-10000-18140	1888 S CENTURY PARK EAST 150	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.06104	-118.41402	INTERIOR TI TO GROUND FLOOR AND MEZZANINE IN SUITE 150. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8850	17041-20002-41720	814 N SAN FERNANDO ROAD	90065	1	144A219    36	5453006048	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.09066	-118.22723	10/11/2018changes to an approved set of plans.  changes to the interconnection point, line side tap.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8851	10041-20000-07382	18355 W VENTURA BLVD	91356	3	171B125    79	2160008038	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	08/02/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.16757	-118.53255	PLAN CHECK POWER AND ENERGY T. I. FOR (E) RESTAURANT (A OCCUPANCY)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8852	13041-20000-02242	7901-7915 N LINDLEY AVE	91335	3	189B125   489	2102014018	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.21431	-118.5275	New fire alarm system for existing building(s) Some existing devices on the second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8853	11041-20001-23801	2555 E OLYMPIC BLVD	90023	14	121-5A219  42	5170011***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM			PC Approved	11/07/2011 12:00:00 AM	ADDRESS	34.02566	-118.2231	Delta 5 revision to approved plans. Change to array grounding electrode from penthouse building steel on roof to building grounding electrode system at service. Dependable Highway Express commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8854	12041-20000-09496	9654 N COZYCROFT AVE	91311	12	201B109   242	2748003088	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	34.24578	-118.58185	Plan check for energy. No emergency lighting. Fire damage. 1361 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8855	18041-10000-45785	11830 N PORTER VALLEY DR	91326	12	216B117   223	2822008005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.28675	-118.55351	PV2. NEW ROOFTOP SOLAR WITH 7.92KWDC SYSTEM SIZE. SYSTEM CONSIST OF 22 MODULES (AC MODULE X22-360-D-AC) AND COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8856	12041-10000-23501	1057 S MARIPOSA AVE	90006	10	129B197   478	5078017013	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.05106	-118.29911	Plan check 4.08KW roof mounted photovoltaic system using Aurora transformerless inverter for a 2 family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8857	14041-10000-09288	2630 S ALMA ST #2630	90731	15	009B197   863	7463017005	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Apartment			04/08/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Expired	08/05/2016 12:00:00 AM	ADDRESS	33.72005	-118.29889	PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3000A-US-ZB-U. (10) Modules: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8858	13041-20000-20137	7600 S AVALON BLVD	90001	9	099B205    94	6023017900	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM	07/29/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	PIN	33.97099935	-118.26484019	New Fire Alarm System. Single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8859	19041-20000-33731	201 N ASHDALE PL	90049	5	138B145   231	4366008028	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	10/26/2019 12:00:00 AM	ADDRESS	34.0753	-118.46214	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 18.2 KW DC/15.47 KW AC. SCOPE OF WORK CONSISTS OF (52) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8860	15041-10000-30133	2213 E 113TH ST	90059	15	087A217   181	6067015004	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	33.93256	-118.23302	PV1, INSTALL NEW 5.565 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(21) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8861	19041-10000-49352	1660 W ANAHEIM ST	90731	15	030B197    11	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM			PC Info Complete	02/21/2020 12:00:00 AM	ADDRESS	33.77884	-118.29327	FULL PLAN CHECK FOR THE ADDITION OF TWO NEW 5 HP BLOWERS TO AN EXISTING SULFUR VENT LINE IN A HAZARDOUS LOCATION, THE SCOPE OF WORK ON THE PLANS IS INDICATED BY A CLOUD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8862	18041-10000-47761	10300 S GLASGOW PL	90045	11	090B173   236	4129031002	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	02/16/2021 12:00:00 AM	ADDRESS	33.94296	-118.37069	FULL PLAN CHECK FOR TENANT IMPROVEMENT TO (E) AUTO BODY. SCOPE OF WORK INCLUDES NEW 800 AMP SERVICE, PANELS, CIRCUITS AND LIGHTING. TOTAL SQ. FT. 15,894.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8863	15041-20000-30518	10880 W WILSHIRE BLVD 17th Floor	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 22,865 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8864	19041-10000-34857	5544 N BONNER AVE	91601	2	174B173  1094	2350005051	R4-1L	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Apartment			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.17122	-118.37401	FA PC for an apartment building. system consits of 1 FACP and 51 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8865	18041-20001-23742	8238 N TAMPA AVE	91335	3	192B117   781	2104001036	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.22016	-118.55334	Plan check for Title 24 energy only in existing space T.I. change to use from retail to massage parlor.  Total area: 1126 sq ft. Note: Building permit has been issued under 18016-20000-15700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8866	17041-10000-44916	695 S SANTA FE AVE	90021	14	124-5A217 204	5164019031	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	34.03508	-118.23039	NEW FIRE WARNING SYSTEM FOR MULTI-USE APARTMENT BUILDING, NON HIGH RISE BUILDING. (1) FA PANEL AND (1120) FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8867	19041-20000-30918	4208 N ALLOTT AVE	91423	4	165B157   924	2373009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.14616	-118.4281	PLAN CHECK FOR NEW BATTERY BACKUP FOR EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK CONSISTS OF A 13.5 KWH BATTERY AND A 125A SUB PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8868	16041-20000-31365	11828 W RUNNYMEDE ST	91605	2	186B169   615	2317017013	(T)(Q)RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			09/02/2016 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.20554	-118.39122	Plan check for power and energy. Project site is a new 3-story, 26-unit apartment building. Work includes a new 1200-amp service, associated boards and loads, and a total lighting area of 24,410 sq. ft. fire alarm variance has been submittedNote: Building permit has been pulled under 16010-20000-02561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8869	19041-10000-22603	350 S HILL ST	90013	14	130-5A211 149	5149015024	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.05047	-118.24998	TEMPORARY POWER FOR A NEW PROPOSED 33-STORY,  MIXED USE BUILDING (428 UNIT APARTMENT, GARAGE AND RETAIL). SCOPE INCLUDES A NEW 2000A 277/480 3 PHASE 4 WIRE SERVICE WITH A NEW 250HP FIRE PUMP, MANLIFT AND OTHER MOTOR EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8870	19041-20000-28945	545 S SAN PEDRO ST	90013	14	127-5A213 295	5148013006	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.04311	-118.24486	Plan check for Title 24 only in existing space outdoor lighting area: 5609 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8871	11041-10002-01491	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Closed	07/15/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	New fire alarm system for the Tom Bradley terminal. EPC is for power. (South concourse) ((((( addition of vesda systems to previously approved set 10-19-11 )))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8872	11041-10000-10894	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	"INSTALL A NEW FIRE ALARM SYSTEM IN THE ""BRADLEY WEST CORE"" OF THE ""TOM BRADLEY"" BUILDING IN LAX."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8873	16041-10000-39554	777 S MISSION ROAD	90023	14	123A219    20	5171024012	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.03217	-118.22542	Plan check for power and Title 24.  Installation of 5 new condensing unit coolers and lighting throughout refridgerated warehouse.  Total new load > 400 amps.  Area = 13,505 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8874	17041-10000-18531	523 W 6TH ST 7TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	TItle 24 plan check.  T.I. to two areas of existing corridor in commercial highrise (7th floor).  New lighting.  Total area = 1,804 sq. ft.       Building permit #16016-10000-26291	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8875	15041-10000-16660	2147 W SANTA YNEZ ST	90026	13	139-5A207 230	5402036020	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Apartment			06/01/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.07584	-118.26633	FIRE ALARM SYSTEM, 2 DEVICES AND 1 CONTROL PANEL .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8876	15041-10000-27877	7376 W 83RD ST	90045	11	096B157   357	4114029029	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	33.9613	-118.4253	PV1INSTALL ROOF MOUNTED PV SYSTEM STANDARD PLAN SIZED 5.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8877	18041-20002-29348	22408 W SOUTH SUMMIT RIDGE CIR	91311	12	198B101   220	2727022030	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM	ADDRESS	34.24008	-118.61499	8/27/2018changes to an approved set of plans.  changes to the modules LG 360 Watts and module layout only.  this is plan check only.    ((((PV1.  Install 15.4 kW roof mounted grid tied PV system.  (44) modules with (2) 7.6 kW rated string inverter.Final Permit Fees: $47.75 due Assembly Bill 1414 and California Senate Bill 1222))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8878	10041-10000-14953	711 W COLLEGE ST	90012	1	135A213    31	5414001009	C2-2D-O	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.06555	-118.24154	Install new optional emergency generator, UPS, panels, and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8879	19041-10000-07836	10960 W WILSHIRE BLVD 21ST FLR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.058	-118.44597	T-24, ENERGY ONLY PLAN CHECK FOR A TI ON 21ST FLOOR OF AN OFFICE BUILDING. SCOPE INCLUDES NEW CIRCUITS FED FROM EXISTING PANELS, EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFECTED AREA IS 4274.B#: 19016-10000-06069.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8880	17041-10000-29749	858 E 46TH ST	90011	9	112-5A209 240	5108024009	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	03/31/2018 12:00:00 AM	ADDRESS	34.0016	-118.26054	PC FOR PV SYSTEM. 3.8KW AC TOTAL OF 15 MODULES. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8881	16041-10000-05407	22222 W VICTORY BLVD BLDG F	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUDRY ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8882	13041-10000-19393	6801 W HOLLYWOOD BLVD A2-201-A3-301,303	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.10229	-118.33907	Tenant improvement to units in shopping complex on corner of Hollywood and Highland belonging to Starline Tours.  New 75 kVA transformer and 3 new panels.  Modify outlets and lights per new layout.  Newly connected load < 400 A, title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8883	10041-10000-02132	2049 S CENTURY PARK EAST #1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/27/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	T.I. for existing high rise building at 19th floor.  Install general and emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8884	14041-10000-09076	11820 W STANWOOD DR	90066	11	117B153   275	4250002011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Expired	04/29/2016 12:00:00 AM	ADDRESS	34.01922	-118.43814	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(18)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8885	16041-10000-44221	6609 W SANTA MONICA BLVD	90038	4	144B185  1261	5532023***	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.09086	-118.33367	PC for energy only to an existing tenant space. Change of use to a pharmacy. Adding new panels, total load is less than 400 amps. New lighting. Total affected area: 1997.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8886	16041-10003-41785	1882 S COCHRAN AVE	90019	10	126B177   720	5067020018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.04209	-118.35452	12-08-2017 Changes to an approved set of plans for PV System. Changes include down size the PV system to 15KW, change system interconnection of the main panel. Changes has been clouded. This is Plan check only. Permit is pulled under application Number: 16041-10000-41785*******************************Previous Work Description***************************PV INSTALL NEW 23.544 KW DC/23.040 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(72) AC MODULES: SPR-E20-327-C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8887	11041-20002-01083	13904 W SATICOY ST	91402	6	186B153    34	2214023021	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.21016	-118.43582	Changes from previously approved plans.  Changes include from two PV systems to one 22.77 KWdc PV system, relocate mounted module locations.Note: Previously appoved plan submitted for reference only.*****PLAN CHECK FOR ROOF MOUNTED 7.59KW AND 7.59KW PHOTOVOLTAIC SYSTEMS WITH 2 EXISTING SERVICES SUPPLYING BUILDING.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8888	13041-20000-34916	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	PC FOR T24 ENERGY ONLY. NEW LGIHTING IN BASEMENT. POWER LESS THAN 400A. NO PATIENT CARE CHECK REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8889	10041-10001-15415	719 N YALE ST 1-60	90012	1	133-5A213  25	5407024005	R4-1	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	ADDRESS	34.06189	-118.24178	REVISED ELECTRICAL PLANS- LEVEL P4 WAS DELETED FROM THE PLANS AND REVISIONS TO APPROVED SET OF PLANS ARE RESPONSE TO THIS BUILDING CHANGE. NEW AUTOMOBILE LIFTS AERE INSTALLED TO MEET THE PARKING SPACES REQUIREMENT PANEL BOARDS WERE RELOCATED AND 1 NEW PANEL ADDED WITH CIRCUITS. NO CHANGES TO THE RESIDENTIAL UNITS(((((((((((((New 5 story, 60 units apartment building with 4 levels of garage below grade.; 14 DIFFERENT TYPES OF UNITSVARIANCE WAS SUBMITTED TO SEPARATE THE FA PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8890	14041-10000-34642	800 S MCGARRY ST M-1	90021	14	123A215    97	5146010012	M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.03009	-118.23943	ENERGY TITLE-24 PLAN CHECK ONLY FOR NEW COOKING EQUIPMENT, PRO AND AIR CURTAIN FOR TAKEOUT RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8891	19041-10000-35119	2966 W WILSHIRE BLVD	90010	10	133-5A201  48	5077013012	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2122.04	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.06167	-118.28604	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8892	17041-10000-38270	723 N JUNE ST	90038	4	141B185   453	5524008009	R1R3-RG	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Expired	10/01/2023 12:00:00 AM	ADDRESS	34.08413	-118.3343	Installation of a new 5.8KVA 13.5KWH AC Powerwall storage battery to an existing residential PV system.(1)AC Powerwall(2)200A subpanel(1)125A subpanel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8893	14041-20001-04227	8112 N CLEMENS AVE	91304	12	189B093    40	2020021022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.21793	-118.63765	((((expedite fees)))pv1 single family dwelling. total system size 7.6kw ac using transformerless inverter nonstandard plan. using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8894	15041-10001-36116	7326 N VANALDEN AVE	91335	3	186B121   819	2104026001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM			PC Approved	12/04/2015 12:00:00 AM	ADDRESS	34.20382	-118.54902	EXPEDITED FEES PER APPLICANT(((PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE: 9KW. (29) MODLUES AND (3) INVERTERS. (29) SUNPOWER SPR-327-NE-WHT-D(3) SMA AMERICA SB3000TL-US-22)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8895	10041-10000-00248	6635 N FALLBROOK AVE	91307	3	180B097   170	2038040005	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM	03/12/2010 12:00:00 AM		Permit Finaled	07/19/2010 12:00:00 AM	ADDRESS	34.18998	-118.6262	Plan check power and energy for TI of existing Target.  New installation of equipment, additional panels, and ckts.  REF.#10042-10000-00263.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8896	16041-10006-38001	4061-4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.99055	-118.44379	ADDITION OF TWO 100A PANELS AND CIRCUITS ; CHANGES ARE CLOUDED  AND IDENTIFIED AS DELTA 6 CHANGES(((((PC FOR POWER AND ENERGY FOR A MIXED USED BUILDING (49 UNITS)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8897	15041-10000-41361	3201 S HOOVER ST BLDG#8	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	NEW FA SYSTEM. BUILDING 8	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8898	14041-10000-17468	800 S FIGUEROA ST 1ST FL	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.04771	-118.26116	TENANT IMPROVEMENT IN EXISTING RESTAURANT SPACE WITHIN A 12-STORIES BUILDINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8899	12041-10001-17677	10359 N SEPULVEDA BLVD	91345	7	204B145   114	2649018001	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.25919	-118.46765	Title 24 plan check for changes to approved set.  Delta-2: Changes made to sales floor multi-level switching scheme.Original Work Description: remodel building for a new autozone store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8900	15041-20000-06823	2331 S MALCOLM AVE	90064	5	126B157   575	4320003068	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Expired	04/03/2017 12:00:00 AM	ADDRESS	34.0426	-118.42806	Plan check for PV rooftop mounted system with 2(3kW and 3.8kW) inverters and 20 modules.Note: plan submit over the counter because online gives error while trying to process a permit	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8901	13041-10001-32962	14738 W BLACKHAWK ST	91345	7	204B149   186	2648010007	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.25803	-118.45366	Expedited RSES plan check per applicant request.[][]PV1, Install  4.5 kw DC roof-mounted solar array, interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 18 modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8902	15041-10000-28039	1627 N VINE ST	90028	13	148-5A187 236	5546009904	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.10052	-118.32687	Full plan check for a fist time tenant, TEMPORARY CONSTRUCTION OFFICE USE, Scope includes new receptacle, equipment and lighting. Total area is 2018-SQ feet. Portion of inspection fee is paid under permit #: 15041-10000-21364 PLAN CHK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8903	17041-10001-04963	241 N LAKE ST	90026	13	136-5A205 103	5157018062	R4-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			10/27/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Closed	07/23/2018 12:00:00 AM	ADDRESS	34.06936	-118.27013	PC only, Changes to an approved set of plans, note changes on delta 2. Change of service from 1000A to 120/240 3ph, 1200Amp. Tenant switchboard has been change to single phase as well.INCLUDING ADDITIONAL 4 CIRCUITS.  No additional load. ****Plan check for power and energy. New 4 story, 41-unit apartment building, over one level enclosed parking garage and one level basement enclosed parking garage. 1,000A service. T24 area: indoor - 17,980sqft; outdoor - 3,857sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8904	13041-20000-28089	14724 W VENTURA BLVD SUITE 910	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Approved	10/09/2013 12:00:00 AM	ADDRESS	34.15162	-118.45395	T24 FOR HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON SUITE 910	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8905	18041-30000-22320	11830 W COURTLEIGH DR	90066	11	111B161   908	4233023086	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	33.9977	-118.41835	Plan check for a fire alarm system loacted in a 4-story 29-unit apartment. Scope includes (1) fire alarm panel, (2) power supplies, and (105) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8906	17041-20000-15854	3423 W FERNCROFT ROAD	90039	13	153A207   228	5437020018	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Expired	09/13/2023 12:00:00 AM	ADDRESS	34.11281	-118.26274	Plan check for a PV1 roof-mounted PV system. System size is 4.1 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8907	08041-20001-06771	2728 N FLETCHER DR	90039	13	151-5A211  83	5436031015	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.00	Electrical	Electrical	Apartment			03/02/2011 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	03/22/2012 12:00:00 AM	ADDRESS	34.11066	-118.2508	add 400A swichboard and feeders to existing 6 panels  delete existing gutter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8908	15041-10000-39348	3764 W WILSHIRE BLVD	90010	10	132B193    68	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.06148	-118.30835	T24 ONLY. T.I. FOR AN EXISTING AT&T STORE. TOTAL AREA 5291 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8909	14041-10001-09900	14848 W COHASSET ST	91405	6	186B149   342	2218010002	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM			PC Approved	05/22/2014 12:00:00 AM	ADDRESS	34.20653	-118.45696	((EXPEDITE FEES)))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8910	14041-10001-08395	201 W WASHINGTON BLVD	90015	14	123A207    51	5126027007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	34.03222	-118.26683	CHANGES TO PERMITTED PLANS:  USING CIRCUITS FROM COMPUTER PANEL TO SERVE CUSTOMER  ORDERING PADSFULL PLAN CHECK POWER AND ENERGY FOR A NEW MCDONALD BUILDING. TOTAL AREA(INDOOR+ OUTDOOR) 62986 SQ FT. (BUILDING #S 14014-10000-00776 & 14010-10000-00526)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8911	14041-20000-13130	10663 W KINNARD AVE	90024	5	132B153   770	4326024022	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Apartment			05/16/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.0558	-118.43356	(N) 6-unit 4-story apartment building.  Power and energy.  Fees adjusted to match applicant check amount, adjust as needed. Fire alarm variance filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8912	14041-20000-26853	5138 N LOUISE AVE	91316	5	171B133   398	2258009020	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.16443	-118.50966	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222PV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8913	17041-20000-22157	18537 W STRATHERN ST	91335	12	189B125   271	2103009***	(Q)RD6-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Re-Activate Permit	11/07/2019 12:00:00 AM	ADDRESS	34.21576	-118.53751	Plan check for new roof-mounted solar pv system on SFD. There is an existing 3.6kW pv system.New system size is 3kW ungrounded w/(10) 300W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8914	15041-20000-32727	11984 N NUGENT DR	91344	12	216B129   189	2601051020	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.28902	-118.51577	PV1. Install roof mounted PV system szied 11 kW. Interconnected with main service panel.(51) Kyocera KU 265 Modules(1) ABB PVI 6000 Inverter(1) ABB PVI 5000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8915	13041-20000-01565	6400 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	01/22/2013 12:00:00 AM	ADDRESS	34.18688	-118.64253	Plan check for energy only. Chase bank. 2685 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8916	10041-20001-23357	4209 S ALAMEDA ST	90058	9	114A215    82	5116024033	M2-2	South Los Angeles	2281.00	Central Alameda		2281.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.00559	-118.23945	Revision to approved plans marked Delta 3.  Revision - change from supply side to load side interconnection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8917	19041-10000-39583	1411 W 190TH ST Suite 365	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	33.85852	-118.30317	PLAN CHECK ONLY FOR  FOR ENERGY ONLY, SCOPE OF WORK IS INSTALLING LIGHTS IN AN OFFICE SPACE. TOTAL AFFECTED AREA IS 1560 SQFT. NOTE PERMIT FEES HAVE BEEN PULLED UNDER 19041-40000-25192	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8918	15041-20001-14866	16826 S ORCHARD AVE	90247	15	066B197   124	6121009050	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM			PC Approved	05/23/2015 12:00:00 AM	ADDRESS	33.87837	-118.28746	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (28) power optimizers. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8919	10041-10001-00391	9185 N DE SOTO AVE	91311	12	198B109   127	2746009022	(T)(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM			PC Approved	09/27/2010 12:00:00 AM	ADDRESS	34.23801	-118.5888	MODIFY LIGHTING SYSTEMPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8920	13041-20000-29036	11988 W VENTURA BLVD	91604	2	162B165   132	2369015016	(Q)C2-1VL, (Q)P-1VL, C2-1VL, P-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.1435	-118.39329	T24 FOR CHANGE OF USE 2,934 sq ft FROM RETAIL TO MASSAGE PARLOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8921	14041-20001-08404	10946 N REMMET AVE	91311	12	210B105   161	2722032008	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.26933	-118.60022	Epedited per applicants requestPV1. Roof-mounted PV System, with 9.5kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8922	18041-10000-03055	7891 N DEERING AVE	91304	3	189B105   348	2109001008	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.21354	-118.59518	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. PLAN CHECK T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8923	13041-10001-14140	1019 N AVALON BLVD	90744	15	033B205  1059	7420022020	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	33.78342	-118.26301	CHANGES TO PERMITTED SET OF PLANS- PANELS RENAMED AND ADDED SOME CIRCUITS))))))))PLAN CHECK FOR POWER AND ENERGY. SERVICE UPGRADE TO 600A. 9 TENANT SPACES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8924	17041-10000-06588	11409 W PENROSE ST	91352	6	192B169   411	2632011012	M1-1-G-CUGU, M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.22308	-118.37994	FULL PC FOR POWER AND ENERGY. TI TO (E) OFFICE/WAREHOUSE BUILDING. TOTAL CONNECTED LOAD > 400A. SCOPE INCLUDES ADDING A NEW 400A 120V/240V 3 PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 11323 SQ. FT.  B#16016-20000-11409	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8925	14041-20000-34810	6706-6708 S SAN PEDRO ST	90003	9	102B205   169	6011012057	R3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	33.97854	-118.26941	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2 KW. INERCONNECTED WITH MAIN SERVICE PANNEL. (14) SUNPOWER E20-327 MODULES(1) AURORA PVI-4.2 TL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8926	14041-20000-02651	8724 N LUCIA PL	91352	6	195B173   474	2408009035	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.22833	-118.36823	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8927	16041-20000-39328	13548 W CANTARA ST	91402	6	192B157   817	2301003002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.21974	-118.42828	Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with 100A MSP.3.8kW ungrounded system. (14) 290W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8928	17041-10000-03406	1716 E MARENGO ST	90033	14	133-5A223  44	5201018032	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.05846	-118.21226	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES ADDING/REPLACING INDOOR AND OUTDOOR LIGHTS, AND RECEPTACLES. A-OCCUPANT LOAD <100. TOTAL AFFECTED AREA IS 5469 SQ. FT. . B#16016-10000-25141	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8929	13041-10000-18476	9989 W REEVESBURY DR	90210	5	153B153   283	4383023012	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.11163	-118.43715	PV1 ROOF MOUNTED SOLAR INSTALLATION USING POWER OPTIMIZERS. PLANS SUBMITTED BEFORE IMPLEMENTATION OF RSES FEE SCHEDULE. SYSTEM SIZE IS 6.615 KW DC AND 6 KW AC. USING TWO STRINGS AND 27 MODULES. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: SOLAREDGE # SE60000A-US |||| POWER OPTIMIZER: SOLAREDGE # OP250-LV-MC4SM ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8930	13041-10001-02551	920 S BROXTON AVE	90024	5	135B149   572	4363018008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM			PC Approved	04/23/2013 12:00:00 AM	ADDRESS	34.06313	-118.44685	supplemental to approved set of plans. value of wattage for a fixture has been changed to more accurately calculate installed wattage. still in compliance. pc for recalculations.Lighting change to existing restaurant.  Load is less than 400 amps and occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8931	14041-10000-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.0504	-118.26023	"PLANCHECK FOR POWER AND ENERGY. HIGH RISE CORE AND SHELL BUILDING INCLUDING 5 LEVEL PARKING GARAGE. "" WILSHIRE GRAND "" PROJECT. [[ FEES BASED ON APPLICANT; PLANCHECKER TO VERIFY]]"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8932	13041-10000-17277	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	33.97808	-118.40726	PLAN CHECK FOR FIRE ALARM SYSTEM. 1 FIRE ALARM CONTROL PANEL AND 5 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8933	16041-10000-05811	3550 W WILSHIRE BLVD SUITE 105	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.06157	-118.30226	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT, CHANGE OF USE FROM OFFICE TO COFFEE SHOP. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1555 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8934	15041-20000-10430	1159 N SOMERA ROAD	90077	5	144B145    36	4369031030	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.09426	-118.45845	Plan check for PV system ground mounted 7.28kW system with 26 modules(SunModule Plus SW280 Mono) and 1 inverter(Fronius Promo 7.6-1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8935	18041-20000-09155	16301 W CELINDA PL	91436	5	165B137   155	2284017009	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.15033	-118.48871	PV1.  Install 16.2 kW roof mounted grid tied PV system.  (54) modules with 7.6 and 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8936	17041-10000-29089	345 N WESTMORELAND AVE	90004	13	138B197    81	5501002033	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Apartment			08/16/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.07753	-118.28811	PLAN CHECK FOR ROOFTOP SOLAR SYSTEM - SYSTEM SIZE(18KWac) CONSISTING OF 2 CENTRAL INVERTERS(SOLAREDGE SE9KUS) AND 61 MODULES(HYUNDAI-S350TI) WITH 32 POWER OPTIMIZERS(P700)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8937	17041-10001-25990	12114 N DARBY AVE	91326	12	219B121   405	2870003003	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2017 12:00:00 AM			Reviewed by Supervisor	08/07/2017 12:00:00 AM	ADDRESS	34.29297	-118.54163	EXPDITE REQUESTED BY APPLICANT FOR ROOF MOUNTED PVOVER 10 KWAC *****************************************************PC FOR ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 10.8 KW ACSCOPE INCLUDE 31 MODULES WITH OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8938	14041-20000-31403	12723 W LEMAY ST	91606	2	180B161   332	2325009012	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.19181	-118.41017	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING SINGLE TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 14 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8939	15041-20000-07002	6550 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.18956	-118.60562	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NEW ACCESSORIES DEPARTMENT IN NEIMAN MARCUS TOPANGA PLAZA. 1374 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8940	17041-20000-12021	9911 N TOPANGA CANYON BLVD	91311	12	201B101    82	2745004060	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.25032	-118.60628	Change of use from retail to medical office - optometry.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8941	18041-20000-44056	16801 W LASSEN ST	91343	12	201B137   146	2685012022	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	02/02/2019 12:00:00 AM	ADDRESS	34.25037	-118.49805	Plan check for a PV1 roof-mounted PV system. System size is 17.78 kWdc/13.1 kWac and consists of (45) modules, (45) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8942	13041-20000-25243	11175 W SANTA MONICA BLVD 8TH FLR	90025	5	129B149   297	4324035029	M1-2	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.04739	-118.44609	RENOVATION OF LIGHTING ON 8TH FLOOR. PC FOR T24 ENERGY ONLY. TOTAL AREA 10369 SQ FT PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8943	11041-10000-27498	350 S GRAND AVE 37th FL	90013	9	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	PIN	34.05160512	-118.25169569	removing walls and open area to open office-new circuits and luminairesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8944	18041-20000-04877	12431 W BURBANK BLVD	91607	2	174B165   696	2340016084	P-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.1723	-118.40408	replace existing metal halide fixture with new led fixtures.  plan check for energy outdoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8945	16041-10000-33196	2271 E CENTURY BLVD 101-208	90002	15	093A217   271	6049019***	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	33.94668	-118.23138	PC for a power only for a New 3-story 14 unit apartment Building E1 (BLDG 2 OF 8).  Scope includes a new 600A 120/208V 3 phase 4 wire service/distribution board. One plan is submitted for multiple apartment buildings. B#16010-10000-02985	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8946	14041-20001-14321	17087 W SAN JOSE ST	91344	12	207B133   836	2695010021	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.26127	-118.50549	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 6kW(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(23) Trina Solar #TSM-255PA05.18 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8947	15041-20001-36560	7840 N WOODMAN AVE	91402	6	189B157   586	2214026148	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	ADDRESS	34.21398	-118.4307	8.30.2016 - Plan check for modifications to approved set. Reducing system to 38.8kW - (1) 6kW inverter and (4) 8.2kW inverters; (228) pv modules. Connecting to load side of 600A main service panel instead of a line side tap. Update single line and roof plan to reflect changes. Changes clouded.=====Plan check for PV roof mounted system. System size: 79kW and 8 inverters (8.2kW and 6.0kW) and 264 modules.Note: Fees $0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8948	16041-10000-25956	10939 W PICO BLVD	90064	5	126B157  1057	4322009019	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.03917	-118.43087	TI FOR OPTOMETRY. PC FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8949	17041-20000-14109	13335 W MAXELLA AVE	90292	11	108B153  1268	4230006027	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.98802	-118.43906	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,118 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8950	16041-30000-20832	13115 W EBELL ST	91605	2	192B161   404	2304010012	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.21911	-118.41888	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (25) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8951	16041-10000-02987	4618 W MAUBERT AVE	90027	13	147B197   609	5542015010	R4-2	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Expired	03/05/2018 12:00:00 AM	ADDRESS	34.09885	-118.29019	PLAN CHECK FOR 600 AMP DISTRIBUTION BOARD FOR NEW MODULAR BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8952	16041-20000-17444	12234 W SHERMAN WAY	91605	2	183B165    79	2321001018	[Q]M1-1VL, [Q]P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.20057	-118.39993	Plan check Title 24 only T.I. retail store in existing space. Total area: 25,704 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8953	14041-20000-18229	11130 N WHITMAN AVE PV 1	91344	12	210B141   432	2666028018	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Expired	08/11/2016 12:00:00 AM	ADDRESS	34.27303	-118.47779	Roof mounted PV system with system size 6KW.Note: Zoning Clearance and Partial of permit is  under 14041-20000-17107.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8954	13041-10000-30838	3609 S ROXBURY ST	90731	15	006B197   419	7469019025	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	33.71302	-118.29753	PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 3.75 KW.(15) TRINA SOLAR # TSM-250PA05.18(15) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8955	15041-10000-24054	1500 W PACIFIC COAST HWY REC B	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR New recreation bldg (accessory to apartment complex WITH 13 DIFFERENT ADDRESSES) 22 DEVICES AND ONE CONTROL APNEL AND ONE ANNONCIATOR & ONE COMMUNICATOR PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8956	14041-20001-07208	20212 W VALERIO ST	91306	3	186B113   670	2114012121	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.20423	-118.57356	Roof mounted PV system with 7.5KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8957	17041-10000-38221	2241 N EASTERN AVE	90032	14	138A231   123	5215035046	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.07163	-118.18066	new single story church community building	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8958	12041-10000-03357	3750 W SANTA ROSALIA DR # 1-C	90008	8	114B185  1258	5032022***	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	02/15/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.00802	-118.33889	First -time tenant ; commercial space developed to officesPlan chk is for title 24 and power	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8959	16041-20000-20616	12640 N CLASSICS DR	91344	12	219B125    32	2601063006	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.29756	-118.5255	Plan check for PV roof mounted system. System size: 6.0kW with 25 modules and 1 inverter(6.0kW). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8960	17041-10000-00875	1575 N GOWER ST ROOF	90028	13	148-5A189 331	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Issued	01/31/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	TI TO ROOFTOP. NEW LIGHTING. PROVIDING T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8961	18041-10000-09029	991 W FRANCISCO ST	90502	15	057B197    57	7351034047	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.84994	-118.29346	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8962	17041-20000-38931	12406 N RALEIGH CT	91326	12	216B113   214	2701048013	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.29139	-118.57307	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.72 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8963	19041-20001-29289	971 N ENCHANTED WAY	90272	11	132B121   521	4419003019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.05435	-118.54914	Expediter per applicant requestPlan check for PV system, PV system size: 19.8KW DC, 18.21KW AC with 60 PV modules and 60 microinverters connected to Existing 600A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8964	13041-10000-13412	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	PLAN CHECK FOR TITLE 24 ENERGY AND ENERGENCY LIGHTING FOR OUTDOOR LIGHTING ON EXISTING PARKING STRUCTURE ROOF TOP. POLE LIGHTS MOUNTING HEIGHT LESS THAN 30 FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8965	13041-10000-20362	652 E 90TH ST	90002	9	094-5A207  69	6042012016	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	33.95459	-118.26333	PV1 2.376 KW 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 11) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: yingli {YL245P-29b}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8966	18041-10000-20699	13168 W VAN NUYS BLVD	91331	7	207B157    97	2535022024	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.26762	-118.4197	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8967	16041-10001-23698	14616 W COHASSET ST	91405	6	186B149   371	2218006009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM			PC Approved	11/28/2016 12:00:00 AM	ADDRESS	34.20652	-118.45156	PC ONLY FOR SINGLE FAMILY ROOF MOUNTED PV. PERMIT UNDER 16041-90000-23698SCOPE INCLUDES29 MODULES CANADIAN SOLAR CS6K-280M29 POWER OPTIMIZER  SOLAR EDGE P300SOLAR EDGE INVERTER SE7600A-US (@7.6KW AC)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8968	16041-10000-05413	22222 W VICTORY BLVD BLDG REC	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.18623	-118.61159	TI TO EXISTING REC CENTER. UPGRADING ALL LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8969	14041-10000-03888	8651 N GULLO AVE	91402	6	192B157    59	2627027105	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.22668	-118.42451	PV1, Install 5.75 kW DC roof-mounted solar array for one-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 5000A-US. (23) Modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8970	11041-20000-26092	801 N FAIRFAX AVE Space 101&-102	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1920.00, 1944.00	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.08567	-118.36172	First time tenant for commercial space.  Restaurant to occupy the space.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8971	14041-20000-09444	5955 N VANALDEN AVE	91356	3	177B121   670	2156008022	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.17878	-118.54992	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8972	17041-10000-20349	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Closed	06/07/2021 12:00:00 AM	ADDRESS	34.06259	-118.35341	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8973	15041-10001-07007	9448 N TOPANGA CANYON BLVD	91311	12	198B101    79	2746013020	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Closed	01/25/2017 12:00:00 AM	ADDRESS	34.24211	-118.60602	REVISIONS TO PERMITTED SET OF PLANS; 400A PANELBDS REPLACED WITH 225A PNLBDS AND 225A PNLBDS REPLACED WITH 125A PNLBDS;REMOVE 112.5KVA XFMR  AND ADD 45KVA XFMR; NEW BRANCH CKTS; REPLACE EXTERIOR LUMINIRES WITH LED TYPESALL CHANGES ARE CLOUDED ON THE REVISED PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8974	13041-10001-35853	6360 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Issued	08/13/2015 12:00:00 AM	ADDRESS	34.18619	-118.5972	Modifications to approved set.  30 additional devices to accommodate modified architectural layouts.  (((INSTALLATION OF A NEW FIREALARM DEVICES IN HILTON HOTEL. TENANT IMPROVEMENT. 6 PANELS AND 1302 DEVICES. HIGHRISE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8975	18041-10000-02603	11120-11160 S HINDRY AVE	90045	11	087B173    72	4129038015	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	33.93344	-118.3722	PC for power and energy for new 800A 480/277V service for water treatment plan. Installing new service equipment, 3 panels, re-connecting exising circuits, new water treatment equipment.B# 18016-10000-01497	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8976	19041-10000-03843	6150 N LAUREL CANYON BLVD	91606	2	177B165  1100	2334011029		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Issued	12/10/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	FULL PLAN CHECK FOR FIRST TIME TENANT IMPROVEMENT TO AN EXISTING SHELL SPACE. NEW LOADS ARE FED FROM (2) NEW PANELBOARDS FROM (E) SWITCHBOARD. TOTAL AREA APPROX. 2,542 SQ FT (INDOOR + OUTDOOR)B# 16016-10000-02478	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8977	11041-20000-23646	6600 N TOPANGA CANYON BLVD #002	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	new  Wasabi Sushi TINote: Permit issued under 12041-90000-13795 and 12041-20000-14397	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8978	16041-10001-45157	13730 W VENTURA BLVD	91423	4	165B157   667	2266020004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.148	-118.43213	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGE TO SINGLE LINE, UPDATED FEEDER RATING AND PROVIDED UPDATED LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8979	16041-20000-44779	20701 W PLUMMER ST	91311	12	201B109   305	2748003071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.24287	-118.58449	CHANGE OF USE FROM REC VEHICLE STORAGE TO STORAGE OF HOUSEHOLD GOODS.  PLAN CHECK FOR ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8980	18041-10000-15072	624 S GRAND AVE	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	PC FOR NEW FA SYSTEM FOR ONE WILSHIRE INFRASTRUCTURE BUILT OUT FOR GENERATOR ROOM 1ST AND 2ND FLOOR. SCOPE INCLUDES SATELLITE FACP TO COMMUNICATE WITH MAIN FACP (UNDER DIFFERENT PERMIT) AND 19 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8981	19041-10000-23889	806 E 61ST ST	90001	9	105B205   594	6007009014	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Closed	07/02/2020 12:00:00 AM	ADDRESS	33.98431	-118.26099	POWER PLAN CHECK TO RELOCATE AND UPGRADE SERVICE FROM 200A TO 800A 120/240 3P, 4W.NO CONNECTED LOAD. ALL NEW LOADS ARE SUBJECT TO PLAN CHECK .	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
8982	13041-10000-24454	200 E ANAHEIM ST 1ST FLOOR	90744	15	030B209   236	7423012031	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	33.77994	-118.2608	TI, REMODELING OF EXISTING MEDICAL OFFICE/EXAM IN A TWO-STORY BUILDING. WORK IS PERFORMED ON THE FIRST FLOOR. APPROXIMATE OFFICE SIZE IS 54,000 SF. REMODELING WILL BE FOR ADDING NEW LOADS ON EXISTING PANELS AND LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8983	15041-10001-29330	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	04/26/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE MADE UNDER DELTA 14 & 15. CHANGES INCLUDE REMOVING AND REPLACING A LIGHTING FIXTURES ON FLOOR PLANS, REMOVED ELECTRIC WATER HEATERS FROM HVAC EQUIPMENT SCHEDULE, AND  ADDING A CONTROL CABINET. ALSO THE LOAD FOR THE MAKE-UP  AIR UNIT IS REVISED TO REFLECT WHAT IS ON THE FIELD. NOTE: PERMIT PULLED UNDER PCIS#15041-10000-29330(((Full PC for power and energy for a commercial bldg (restaurant/eat-carry out). NOTE TO PLAN CHECKER: FOR T-24, PERFORMANCE FORMS WERE USED INSTEAD OF PRESCRIPTIVE METHOD. sqft = 3088	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8984	17041-10001-20037	902 S 4TH AVE	90291	11	108B145   604	4239010022	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			06/14/2017 12:00:00 AM			Reviewed by Supervisor	06/20/2017 12:00:00 AM	ADDRESS	33.99368	-118.47158	Expedite fees only.       Installation of new roof mounted solar PV system on existing 3 unit residential building.  Central inverter system.  Total size = 3 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8985	19041-20000-44799	3772 E SAN RAFAEL AVE	90065	1	148-5A221 129	5464015011	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.10048	-118.21876	PV1 PLAN CHECK FOR 13.32 KW DC/11.89 KW AC CEC PV SYSTEM. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH MICROINVERTERS, AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8986	19041-20000-34233	3730 N WESTFALL DR	91436	5	162B137   459	2293006008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			Reviewed by Supervisor	09/13/2019 12:00:00 AM	ADDRESS	34.13857	-118.49393	PV1.  Install 12.285 kW roof mounted and grid tied PV system and 27 kWh energy storage system.  (39) modules with 11.4 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8987	10041-20000-13003	7250 N CANOGA AVE	91303	3	186B105   631	2111029001	(T)(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM			PC Approved	07/07/2010 12:00:00 AM	ADDRESS	34.20263	-118.59751	Revision to approved plan # 09041-10000-21095. change is on single line diagram and drewn according as installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8988	10041-20001-05555	4419 N VAN NUYS BLVD	91403	2	166-5A151  71	2265010013	C2-1L, [Q]R3P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.00, 1413.01	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	04/01/2010 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	34.15157	-118.44891	INSTALLING LIGHTING FIXTURE IN LAUNDARY OF NAIL SALON. THIS P/C IS FOR TITLE 24 ENERGY ONLY. supplimental to existing permit 10041-20000-05555 change of contractor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8989	14041-20000-07799	3650 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.02081	-118.28964	PC FOR T24 ENERGY ONLY. TOTAL AREA 2955. NEW LIGHTING IN BASEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8990	14041-20000-33672	16100 W SAN FERNANDO MISSION BLVD	91344	12	210B141   560	2667002006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.27176	-118.48249	PV1 SFD. TOTAL SYSTEM SIZE 5.5KW AC USING MICROINVERTER STANDARD PLAN. USING TOTAL OF 22 MODULES. ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8991	14041-10001-28862	1635 N CAHUENGA BLVD	90028	13	148-5A187 221	5546007028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.10071	-118.32971	PC FOR T24 ENERGY ONLY. TI FOR A OFFICE .TOTAL AREA 1478 SQ FT.   (((( 12-11-14 m.zandi changes made to bathroom emergency lighting using bug eyes.))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8992	13041-20000-03497	1668 S CRESCENT HEIGHTS BLVD	90035	10	129B173  1258	5068009012	R1-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.04709	-118.37342	Photovoltaic system on the roof of a single family dwellling using a transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
8993	17041-30000-36790	947 N WILCOX AVE	90038	13	144B185   995	5533022038	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			10/12/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.08844	-118.33125	Plan check for new fire alarm system. Total number of fire alarm devices: 39 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8994	18041-10000-33410	1010 N TIGERTAIL ROAD	90049	11	138B141    63	4494006023	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.07757	-118.48489	plan check for PV1 5KW AC roofmounted system with (14) modules and (1) 5KW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
8995	19041-10000-22472	2007 W JEFFERSON BLVD	90018	10	120B189   675	5052023038	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	12/07/2020 12:00:00 AM	ADDRESS	34.02567	-118.31541	Energy plan check for a change of use from a (E) retail to an office/ art studio. Scope include new lighting and and equipmnet with a total lighing area of 904-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8996	15041-20000-14385	11301 N YARMOUTH AVE	91344	12	210B129    43	2711017017	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.27582	-118.52112	Installation of new roof mounted solar PV array.  Total system size = 8.815 kWac.  Microinverter system with 3 branch circuits.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
8997	17041-10001-07542	20929 W VENTURA BLVD Building B	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	"[[7/31/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING FEEDER SIZES AND BREAKERS FOR FUTURE PANELS TO THE ""MSB"" MAIN SWITCHBOARD ]]]]Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600-amps.Note: Building application has been generated under 16016-20000-22113"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8998	19041-10000-12815	11920 N BALBOA BLVD	91344	12	216B133   440	2610001007	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	34.28691	-118.5016	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
8999	15041-20000-00612	1880 CENTURY PARK EAST SUITE 820	90067	5	132B161     8	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	PIN	34.06194805	-118.41416758	TI to existing high rise commercial building. Plan check for energy and emergency lighting only. New lighting new controls using existing pannel. Total sqft. 1759. Scope of work to be done in suite 820.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9000	14041-20000-08662	1910 S LA CIENEGA BLVD	90034	10	126B173   520	5066004018	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.04218	-118.37626	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EXISITNG GARAGE PARKING. 384 SQFT. ""COMPLY WITH DEPARTMENT ORDER effective date 10/01/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9001	10041-20000-11685	1415 S REXFORD DR 1-10	90035	5	132A167   265	4306003005	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			06/18/2010 12:00:00 AM	06/18/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	34.05465	-118.39452	replacing  FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9002	15041-10000-38582	1150 S OLIVE ST 24TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN CORRIDOR AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9003	12041-10000-27442	5025 W JEFFERSON BLVD	90016	10	120B181   753	5049033017	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.02566	-118.35294	FULL PLAN CHECK. UPGRADING ELECTRICAL SERVICE TO 600 AMP AND INSTALLING 5 FEEDERS FOR NON-DWELLING EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9004	19041-20000-40381	18447 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9005	14041-10000-06207	11267 N ADELPHIA AVE	91331	7	210B165   129	2532024026	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.27491	-118.39802	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(8) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9006	17041-10000-44526	629 E 30TH ST	90011	9	118-5A207 169	5128014029	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.01897	-118.26434	Remove otudoor HID fixtures and replace with new LED fixtures. Replacing existing indoor lights with new LED fixtures. PC for T-24 only.TOTAL SQ.FT 54900	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9007	14041-10000-16504	3539 S MOTOR AVE 200 &  300-SUITES	90034	5	120B161   608	4314013030	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.02552	-118.40812	PC FOR POWER AND ENERGY.  TI. FOR OFFICES IN SUITES 300 & 200.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9008	17041-20001-21189	11268 N TELFAIR AVE	91340	7	210B153   180	2616016020	R1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.27488	-118.43734	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.7.6kW ungrounded system. (26) 290W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9009	11041-10000-12353	620 W 2ND ST	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.0545	-118.25027	NEW PARKING STRUCTURE / MUSEUM BUILDING ( 3-LEVELS PARKING AND 3-LEVELS FOR MUSEUM) THIS APPLICATION  IS FOR THE SERVICE AND DISTRIBUTION FOR THE PARKING STRUCTURE; APPLICATION FOR THE MUSEIUM WILL FOLLOW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9010	14041-20000-14601	610 S ST LOUIS ST	90023	14	126A221   213		[Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Apartment			06/02/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.03862	-118.21749	New fire alarm system for low rise building of 5 stories apartments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9011	14041-10001-04165	8063 N GREENBUSH AVE	91402	6	189B157   151	2301008016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.21773	-118.42684	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 6.5 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 6000A-US-ZB-U. (26) Modules: CANADIAN SOLAR CS6P-250PX.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9012	15041-30000-41262	12045 W WATERFRONT DR #460	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Issued	01/19/2016 12:00:00 AM	ADDRESS	33.98209	-118.40611	Title 24 plan check only.  Total area = 5,453 sq. ft.     Office T.I. to to part of 4th floor in existing commercial highrise building.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9013	15041-10000-09913	209 S BROADWAY	90012	14	130-5A213  23	5149009022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Info Complete	04/03/2015 12:00:00 AM	ADDRESS	34.05228	-118.24708	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTNG ONLY.  TOTAL SQUARE FOOTAGE 2250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9014	14041-10000-05368	13450 W MAXELLA AVE #230-240	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	33.98645	-118.44148	PLANCHECK FOR POWER AND ENERGY FOR A NEW RUTH CHRIS RESTAURANT. NEW CONNECTED LOAD > 400 AMPS. BUILDING PERMIT # 14016-10000-03594.  RESTAURANT TENANT IMPROVEMENT WITHIN EXISTING SHOPPING CENTER; THE PROJECT SCOPE CONSISTS KITCHEN, INTERIOR DINING, ATTACHED PATIO DINING, DETACHED PATIO DINING, AND EXTERIOR MODIFICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9015	17041-10001-23342	11401 N PORTER RANCH DR BLDG 9	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 9 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 9 of 10.  Type I.       Building permit #17010-10000-02386	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9016	18041-10004-33164	108 S FREMONT PL WEST	90005	4	132B185   290	5090018010	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.05945	-118.32826	void for fee testing only....Change to approved set by changing the model of PV module and change microinverter to (2) central inverter. All changes under clouded area.Applicant prefer original plan checker J.Hua(((NEW ROOF MOUNTED 16.8 KW PV SYSTEM WITH 56 MODULES and MICROINVERTERS ON A SINGLE FAMILY HOME.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9017	09041-30003-05642	6290 W SUNSET BLVD	90028		147A189    74	5546025024	(Q)C4-2D-SN		Hollywood	Central Hollywood			Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM			PC Info Complete	01/12/2010 12:00:00 AM	ADDRESS	34.09777	-118.32646	1-12-10 - Supplemental is for changes to previously approved plans.  Inspector requested plans to reflect as-built.  All new work is clouded as delta 3.  Permit is for change to address.  P/C is for Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9018	19041-10000-04462	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO-POD, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.12774	-118.26247	PLAN CHECK FOR TITLE 24 ONLY T.I. TO EXISTING RETAIL RESTROOMS TOTAL SQFT 636.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9019	15041-30002-41233	8957 W DAVID AVE	90034	10	126B169   871	4302017030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.04024	-118.38669	03/23/2017 Changes to an approved set of plans. Micro-inverter model and PV module model have changed.04-14-16 Change to approved set of plans. Changes include module layout on roof of garage to roof of house and addition of 2 modules & microinverters(Enphase M250-60-2LL-S22) & load center. ((((((Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 4 kWac.  Microinverter system with 1 branch.))))))))))Note: Fees $0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9020	15041-10000-02573	3618 E UNION PACIFIC AVE	90023	14	117A227    22	5192005802		East Los Angeles	BOYLE HEIGHTS			2049.20	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	PIN	34.0155065	-118.20023569	IINSTALLING 6 EACH POLE-SUPPORTED LUMINAIRES EACH WITH 3 134 LED LAMPS IN A TRUCK PARKING LOTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9021	17041-10000-44843	8500 N BALBOA BLVD STE. 130	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Issued	03/09/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	PC for power and energy for TI comercial medical facility (Located in suite 130). Connecting new 600A DBA and 400A DBB to existing electrical Dist. board. Installing distribution board, new panels, 218kVA generator, two transformers, lights and receptacles.  Areas includes donor rooms for blood extraction, bone marrow collection, and labs. No patient treatment is provided in this facility. Total area is 37003sqft. B# 17016-10000-37033.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9022	10041-10000-24706	1030 W PACIFIC COAST HWY IST FLR	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM			PC Info Complete	12/10/2010 12:00:00 AM	ADDRESS	33.79073	-118.29408	TI IN AN EXISTING HALWAYS OF OFFICE AREA ON THE FIRST FLOOR IN ROOM # 10W03. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMEGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9023	12041-10000-30650	380 W WORLD WAY #T60	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			Reviewed by Supervisor	05/23/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I.  Remodel for airport concession space # T60.  Plan check is for Title 24 only using the Tailored Method.  Applicant wanted to have the T-24 plan check as back room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9024	16041-20000-03398	3145 W GARDEN AVE	90039	13	153B209  1256	5436029032	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.11154	-118.254	Install a roof-mounted solar array on the roof of a detached garage for a SFD. Interconnect with an existing 125A Subpanel, fed from a 50A  breaker on the 200A MSP. Using standard plan.System size: 6kW. Ungrounded system. (21) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9025	10041-20000-21605	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon			1216.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM			PC Approved	10/29/2010 12:00:00 AM	ADDRESS	34.20615	-118.41279	revise feeders and conduits to approved two motors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9026	19041-20000-13394	123 N LUCERNE BLVD	90004	4	138B189   885	5515016016	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.07368	-118.32497	INSTALLATION OF A 12.96KW DC/11.34KW AC/11.73 KW AC CEC ROOFTOP PV SYSTEM FOR A EXISTING SFD. SCOPE OF WORK INCLUDES (36) SUNPOWER SPR-X22-360-E-AC 240V MODULES WITH INTEGRATED MICROINVERTERS AND A 100A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9027	19041-10000-08667	1535 W 62ND ST	90047	8	105B193   680	6002024900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	33.98336	-118.30355	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9028	14041-20000-10130	23433 W ARMINTA ST	91304	12	189B093   446	2020004036	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.21338	-118.63771	Roof mounted PV system with Optimizer and transformerless inverters.  System size 8.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9029	19041-30000-40643	444 S FLOWER ST STE 1600	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	34.05189	-118.25546	PC for energy only, tenant improvement to (E) Office Suite 1600.  Scope of work to include new lighting and receptacles. Total sq. ft. 5820	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9030	13041-10000-34452	9540 N VAN NUYS BLVD	91402	6	201B149   735	2644025901	P-1VL, RD2-1, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.24411	-118.45004	INSTALLATION OF NEW FIRE ALARM SYSTEM IN SINGLE STORY, FULLY SPRINKLERED BUILDING(MULTI PURPOSE CENTER). ADDITION OF 28 DEVICES, 1 FACP. TOTAL SQ FT IS APPROX. 2700 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9031	18041-10000-16880	1973 N EDGEMONT ST	90027	4	150B197   512	5589017024	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.10744	-118.29642	PC FOR ROOF MOUNETD PV ON SFD. SYSTEM SIZE 3.84KW AC / 4.56KWDCSCOPE INCLUDES 16 MODULES WITH MICROINVERTERS IQ-60 AND NEW LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9032	16041-20000-24444	12233 W OLYMPIC BLVD STE 280	90064	11	123B149   494	4259019006	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.03223	-118.45599	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS, NEWLY CONNECTED LOAD <400AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 6447.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9033	17041-10000-08187	555 E RAMIREZ ST SPACE 270	90012	14	132A217   238	5409021900	PF-1XL-RIO	Central	Central City North			2060.20	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.05425	-118.2309	PC FOR AN EXISTING FIRE ALARM SYSTEM AT AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 114 FA DEVICES, AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9034	18041-20001-35525	4955 N VAN NUYS BLVD ste 111	91403	4	169-5A151  13	2263026046	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM			PC Approved	07/03/2019 12:00:00 AM	ADDRESS	34.16078	-118.4489	PLAN CHECK ONLY, SUPPLEMENTAL CHANGES TO APPROVED SET. CLOUDED DELTA 1 CHANGES ONLY. CHANGES TO SINGLE LINE, REDUCTION IN LOW VOLTAGE CONDUCTOR SIZE FROM 10 AWG TO 12 AWG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9035	19041-10001-00302	8500 W BEVERLY BLVD #157	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	08/24/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	Change to an approved set bay adding new ckts and increasing the larger size of HVAC equipment. All changes under delta-2 and 3 only.(((New retail store The Webster LA8750 SQR FT. FULL PLAN CHECK.BULDING PERMIT: 18016-10000-34753)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9036	14041-10000-08927	5934 N TROOST AVE	91601	2	177B169   943	2339009055	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.17862	-118.38651	PV1, INSTALL 5.35 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(19) MODULES: SUNIVA OPT265-60-4-1B0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9037	15041-10000-32920	6800 N OWENSMOUTH AVE STE-190	91303	3	183B105   949	2138006044	CR-1	South Valley				1345.00	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM			PC Approved	10/05/2015 12:00:00 AM	ADDRESS	34.19413	-118.60138	Energy plan check for an office T.I located in the 1st floor of a commercial building. Scope includes new receptalces and lighting; total area is 828-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9038	17041-10000-40878	18717 W HILLSBORO ROAD	91326	12	207B121   488	2728030018	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.2636	-118.54042	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 14.74 KWDC / 12.3KWACSCOPE INCLUDES 44 MODULES WITH MICROINVERTERS WITH NEW LOAD CENTER. ZERO FEES FOR PV DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9039	16041-20000-44392	10250 W CONSTELLATION BLVD 8th Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI to (E) corridor on 8th floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9040	15041-10000-21826	1808 S CARMONA AVE UNIT #1	90019	10	126B177   903	5064010010	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.04106	-118.36071	PV 2, ROOF MOUNTED SOLAR, 2.6 KW PV ARRAY.(1) INVERTER: PVI-3.0-OUTD-S-US-Z-A(10) MODULES: KU2606XPA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9041	16041-10000-34574	5930 W BARTON AVE	90038	13	144B189   950	5534027007	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Apartment			09/29/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.08785	-118.32331	PC FOR POWER ONLY. UPGRADING SERVICE FROM 200A TO 600A  IN A (E) 16-UNIT APARTMENT BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9042	16041-10000-42769	11699 W PICTURESQUE DR	91604	2	162B169   470	2369033017	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.14034	-118.38724	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(35)MODULES-SOLARWORLD SW300(35)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE10000A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9043	18041-20000-26325	17655 W DEVONSHIRE ST Rest Room	91325	12	204B129    58	2733013009	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.25781	-118.51928	Plan check for Title 24 only in existing rest room T.I. new lighting. Total area: 318 sq ft. B#18016-30000-01619	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9044	16041-10000-17241	216 N MALGREN AVE	90732	15	018B189   153	7559007014	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	33.74542	-118.31517	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. STANDARD PLAN IS BE USED. (26)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB # PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9045	19041-20001-30069	2459 N HAVERHILL DR	90065	1	153A219   124	5462024037	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM	ADDRESS	34.11441	-118.22383	08-09-2019 Changes to an approved set of plan, changes include module layout in source circut 3. Plan check only.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9046	13041-10000-36017	10429 N WHEATLAND AVE	91040	7	204B177    38	2542006002	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Expired	05/13/2016 12:00:00 AM	ADDRESS	34.2591	-118.358	PV1, Install 4.25 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3800A-US. (17) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9047	12041-10000-15907	1016 N MISSION ROAD	90033	14	133-5A221  86	5410011001	[Q]M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.0589	-118.21624	Plan check for energy only. Outdoor parking lot for LADOT. 109315 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9048	16041-10000-25954	1149 S HILL ST St 600 W.	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	T-24 Tenant improvement to existing 6th floor office suite. Scope of work includes new lighting and receptacles in a portion of the floor. Total Sq. Ft. 1176	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9049	19041-10000-20510	13847 W DEL SUR ST	91340	7	210B153    70	2616019058	M1-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.27566	-118.43451	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor )- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9050	15041-10000-02412	13309 W WOODBRIDGE ST	91423	4	165B157   697	2360011006	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.14771	-118.42307	Plan check for new fire alarm system with (1) fire alarm panel, (1) communication panel and (128) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9051	14041-10002-16672	5778 W OLYMPIC BLVD	90019	4	132B177   764	5085004036	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			02/22/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM				CHANGES TO AN APPROVED SET.  TO REFLECT FEILD INSTALLATION PER INSPECTION. SCOPE INCLUDES CHANGING THE FEEDER TYPE TO AL. ALL CHANGES UNDER DELTA 3, VOLTAGE DROP REVISED. PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9052	11041-10000-24370	1042 S FREDERICK ST BLDG 2-1	90291	11	111B145   881	4243003032	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/28/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	33.99935	-118.46048	Lincoln Place Apartment Building Project.  New 2-story apt. building with 8 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9053	13041-10000-07674	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	one for one replacement of edwards field addressable devices with siemens and provide new notification tied to existing siemens facp (which used to just monitor the edwards)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9054	18041-20000-02147	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.14947	-118.43885	Tenant improvement of (E) supermarket.  Removal/replacement of of refrigerated and display cases within sales and service departments.  Associated electrical remodel work.  New accent lighting in sales areas.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9055	18041-20003-11355	20433 W NORDHOFF ST	91311	12	195B109    61	2781001036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM			PC Approved	09/19/2018 12:00:00 AM	ADDRESS	34.232	-118.57867	09-17-2018 Changes to an approved set of plan changes include remove load center and add fused disconnect, and replace 2 inverter(33.3kW) to 1 inverter(66.6kW). Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9056	19041-20000-42658	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	11/11/2020 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for replacement of Medium Voltage equipment 2.4 KV transformer, 1600A 277/480 V distribution  and equipment, Scope of work are in 2 phases: 1st phase install 2.4KV transfromer and 1600A  distribution and associate load. 2nd phase install Generator, ATS and distribution sections.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9057	16041-10000-02810	8159 W HOLLYWOOD BLVD	90069	4	147B177   403	5556028016	RE9-1	Central	Hollywood	Bel Air - Beverly Crest		1942.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Issued	04/08/2016 12:00:00 AM	ADDRESS	34.10066	-118.3665	New 600A service on a SFD, PC for Power only, 15,000sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9058	17041-20000-17757	801 N BROOKTREE ROAD	90272	11	126B129   239	4409020011	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.04378	-118.51433	PV1.  Install 15.8 kW roof mounted grid tied PV system.  (48) modules with (2) 7.6 kW inverters with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9059	19041-10000-15908	1520 N SAN PABLO ST	90033	14	135A225    64	5202004044	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			PC Info Complete	04/30/2019 12:00:00 AM	ADDRESS	34.0627	-118.20276	T-24 PLAN CHECK TO CHANGE AN IT ROOM TO SIMULATION COMPUTER-LAB ROOM IN A MEDICAL FACILITY (OFFICE LAB,  NO PATIENTS) . SCOPE INCLUDES NEW 225A PANEL, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 330 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9060	14041-10000-12921	2401 W BEVERLY BLVD	90026	13	136-5A203 160	5157010019	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.01	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	PIN	34.06858015	-118.27392721	1200AMP SERVICE UPGRADE FOR EXISTING ENTERTAINMENT/PRODUCTION BUILDING. SOME LOADS REMAIN EXISTING AND OTHERS NEW AS IDENTIFIED ON THE PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9061	11041-10002-14514	7149 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM			PC Info Complete	03/02/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	NEW FIRE WATER DELUGE PUMP BUILDING AT LAX.  FULL PLAN CHECK.((((((( changes made to previously approved set, remove exhust fans from emergency board feedinf fire pumps and remove neutral from the wiring system. 3-2-12))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9062	16041-10001-14545	2852 S FORRESTER DR	90064	5	126B165   873	4316013003	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.03936	-118.40382	EXPEDITE PER APPLICANT REQUEST.((((PV1. NEW SOLAR SYSTEM  ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 32KWdc / 28KWac.(100)MODULES-LG LG315N1C-G4 BLACK MODULES(100)MICROINVERTERS-ENPHASE S280-60LL-2-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9063	13041-10000-30256	2944 N GLENEDEN ST STORAGE-BLDG	90039	13	150A211    31	5442031901	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.10723	-118.24816	TITLE 24 PART 6 ENERGY PLAN CHECK AND PERMIT FOR A new  storage bldg,  FOR MARSH PARK.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9064	14041-10000-06406	20790 W NORDHOFF ST BLDG 2	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM				NEW CORE & SHELL FOR FUTURE COMMERCIAL BLDG. EPC IS FOR POWER & ENERGY. BLDG#14010-10000-00744. This building is designed as a core and shell building only; separate building, electrical, and mechanical permits are required for all future residential unit build-outs or commercial tenant space  build-outs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9065	19041-10000-00441	330 N FAIRFAX AVE	90036	5	138B177   271	5527037042	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	02/26/2021 12:00:00 AM	ADDRESS	34.077	-118.36127	NEW FIRE ALARM SYSTEM IN A 3 STORY OFFICE BUILDING OVER 2 LEVELS OF SUBTERRANEAN PARKING.  SCOPE INCLUDES 1 FA PANEL AND 120 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9066	19041-20000-46294	13444 W VENTURA BLVD	91423	4	165B157   811	2373007003	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			Reviewed by Supervisor	12/24/2019 12:00:00 AM	ADDRESS	34.14704	-118.4264	FULL PLAN CHECK FOR SERVICE UPGRADE TO 600A, NEW 600 MDP, (3) NEW 200A 3PHASE PANELS,  NEW LIGHTS AND OUTLETS, T24 INCLUDED, TOTAL SQUARE FOOTAGE = 2006 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9067	15041-20000-24516	22022 W CALLE MILAGROS	91311	12	210B101    73	2723005052	(T)(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.2681	-118.60693	Plan check for PV roof monted system. System size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9068	10041-20000-12112	11154-11170 W AQUA VISTA ST BLDG B	91602	2	162B173   143	2366027011	OS-1XL, R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.01	Electrical	Electrical	Apartment			06/24/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.14476	-118.37362	New 3 story 65 units apartment building .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9069	13041-20001-35346	15434 W STARE ST	91345	7	204B145   914	2660008011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.25261	-118.46875	(((EXPEDITE FEES)))PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.6 KW AC USING 42 MODULES 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9070	12041-20000-15958	14401 W VENTURA BLVD	91423	5	166-5A151 296	2265014017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.15069	-118.44613	Install new general lighting in the show/retail area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9071	14041-10000-23523	1100 S SAN JULIAN ST	90015	14	124-5A211 178	5145025001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.03567	-118.25313	PLANCHECK FOR POWER AND ENERGY FOR BLDG 17. FEES INCLUDE SITE PLAN. PLANCHECKER TO ADJUST FEES FOR BLDG 16 AND 17.[[[[[[14016-10000-01915 BUILDING 17 ]VOLUNTARY SEISMIC UPGRADE TO (E)  SINGLE STORY, CONCRETE STRUCTURE W/ BASEMENT WITH INTERIOR AND EXTERIOR ALTERATIONS. NO CHANGE IN USE. NO ADDITIONAL FLOOR AREA.]]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9072	16041-20000-31378	6303 N OWENSMOUTH AVE 6th Floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.18474	-118.60182	Plan check for Title 24 only. Project site is a suite on the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,266 sq. ft.Note: Building application has been generated under 16016-10000-20576	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9073	19041-10000-38601	205 S MISSION ROAD	90033	14	127-5A217  13	5172014001	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.04525	-118.22803	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR & OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9074	14041-20000-01869	9930 N BARTEE AVE	91331	6	201B157    73	2645006017	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.2509	-118.43232	pv1 single faqmily dwelling. total system size 3.8kw ac using transformerless inverter with power optimizers total of 14 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9075	16041-30000-19910	417 S BARRINGTON AVE	90049	11	132B145   106	4401010011	R3-1, RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.06037	-118.46868	NEW FIRE ALARM SYSTEM 170 DEVICES WITH 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9076	18041-10000-47941	2955 N PASSMORE DR	90068	4	157-5A181 308	2427009018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.12533	-118.35187	Permit fee is $0.00 due to AB 1414.New rooftop solar system on a SFD, 22.8 kW AC / 23.075kW DC. Install (65) modules, (65) P400 optimizers, (2) central inverter at 11.4 kW each, (1) new 125A solar load center,  (1)  new 400A subpanel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9077	17041-20000-10257	319 N GLENDALE BLVD	90026	13	136-5A207 349	5159020024	C2-1VL	Central	Westlake	Greater Echo Park Elysian	Yes	2083.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.06613	-118.26058	ti to an existing commercial space.  adding new lighitng new controls to exising panels.  plan check for energy and em lighitng only.  total square footage 3251.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9078	12041-20000-05405	22601 W LASSEN ST	91311	12	204B097    41	2724005902	A1-1XL	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11, 1132.13	Electrical	Electrical	Commercial			03/09/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.25009	-118.61925	Plan check for T-24 energy compliance including emergency egress and exit lights, main service = 400A.NEW MACHINE SHOP BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9079	18041-20000-47581	8201 N TOPANGA CANYON BLVD #13	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			12/14/2018 12:00:00 AM			PC Approved	12/14/2018 12:00:00 AM	ADDRESS	34.21793	-118.6063	ti to an existing commercial building.  adding new lighting new controls to exisin panels.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9080	18041-20000-04462	11311-11321 W CAMARILLO ST	91602	2	168B173   424	2353023018	C4-1	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Apartment			02/07/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/02/2022 12:00:00 AM	PIN	34.1579375	-118.37795623	New mixed use 5-story 60-unit apartment building over one story subterranean garage.  2000A 208Y/120V service.Building permit under 17010-20000-01435.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9081	19041-10000-06252	2023 E CESAR E CHAVEZ AVE	90033	14	129A223    53	5175030025	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	08/29/2020 12:00:00 AM	ADDRESS	34.04907	-118.21249	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9082	13041-10000-27655	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	TITLE 24 ENERGY PLAN CHECK ONLY FOR SIGN LIGHTING. HUDSON NEWS INSIDE LAX. INSTALLING 1 ILLUMINATED WALL SIGN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9083	14041-20000-11027	15853 W MONTE ST 103, 104	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.31022	-118.47637	PLANCHECK FOR T24 ENERGY. T.I. TO  UNIT #103 AND  UNIT #104 . WAREHOUSE. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. 8873 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9084	15041-10000-16415	11818 W WILSHIRE BLVD UNIT 300-PHASE 3	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.0474	-118.46308	PHASE 3:REMODEL OF THE CURRENT TENANTS IN VIRTO FERTILIZATION (IVF) LAB AND ADJACENT AREA IN MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9085	14041-10000-09080	4630 W GAINSBOROUGH AVE	90027	4	153B197   572	5588025027	RS-1	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.11218	-118.29093	"INVESTIGATION FEE ON SUPPLEMENTAL application.PV1, Install 6 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE6000A-US-ZB-U.(24) Modules: CANADIAN SOLAR CS6P-250PX***BEGIN PRINT: 331285 (4/17/14 14:56)Application Number: 14041 - 10000 - 09080Address: 4630 W GAINSBOROUGH-----------------------------------------------NO: 101856  -- Electrical""COMPLY WITH DEPARTMENT ORDER effective date12/16/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation. Ifadditional assistance is needed, please call Inspector SERGIORODRIGUEZ at (213)252-3045 of GENERAL ENFORCEMENT CENTRAL.  CEISCase Number is 428041.(Created: IMSV7 / 12-14-11)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 101855  -- ElectricalINVESTIGATION FEE DUE: NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.(Created: IMSV7 / 12-14-11)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~***END PRINT: 331285 (4/17/14 14:56)"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9086	11041-10000-07042	8538 N VAN NUYS BLVD	91402	6	192B149    81	2638001042	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM			PC Approved	04/08/2011 12:00:00 AM	ADDRESS	34.22587	-118.44892	Ti in an existing retail & cafe. EPC is for T24& Emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9087	12041-20000-26110	725 S FIGUEROA ST 25TH FLOOR	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for energy and emergency lighting. 21475 sqft. SUITE 2500. Commercial high-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9088	17041-20001-38865	1999 S AVENUE OF THE STARS Floors 16-17	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	SUPPLEMENTAL TO CHANGES TO APPROVED SET OF PLAN. CHANGES INCLUDE REMOVAL AND ADDITION OG NEW LIGHTING. LAYOUT AND FORMS HAVE BEEN UPDATED TO REFLECT CHANGES AND CLOUDED ON PLAN ORIGINAL PERMIT Plan check for Title 24 only. Project site is two floors of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,141 sq. ft.Note: Building application has been generated under 17016-10000-27850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9089	18041-10000-38489	907 E 3RD ST	90013	14	129A215   276	5163006089	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			Re-Activate Permit	11/28/2018 12:00:00 AM	ADDRESS	34.04611	-118.23458	****Voided**** Temporary lighting installed no plan check required Conractor to apply for refund for submittal fee. REMOVE EXISTING INDOOR LIGHTING AND REPLACE WITH NEW LED PENDANT LIGHTING. T-24 ONLYTOTAL  AFFECTED AREA IS: 4097 SQ.FT0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9090	08041-10003-22168	448 S HILL ST 3th&4th	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.04896	-118.25139	Changes to plans for the 3rd and 4th floor.  Plan chack for future AC load calcs, resize feeders, and revise lighting and receptacle layout.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9091	08041-20001-24729	1929 S BELOIT AVE 1-63	90025		126B153   502	4261031003	R3-1		West Los Angeles	West Los Angeles			Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM			PC Approved	11/12/2010 12:00:00 AM	ADDRESS	34.04254	-118.44403	PLAN CHECK FOR DELTA 3 REVISION FOR LIGHTING CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9092	18041-20000-43955	18000 W DEVONSHIRE ST	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.25698	-118.52508	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9093	11041-10000-21301	11768 N MARIPOSA BAY LANE	91326	12	216B113    29	2701031015	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2011 12:00:00 AM	11/03/2011 12:00:00 AM		Permit Finaled	11/28/2011 12:00:00 AM	ADDRESS	34.28487	-118.56562	New rooftop PV system for a single family residence.  PLAN CHECK for Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9094	16041-10000-24580	900 S FIGUEROA ST 30TH	90015	14	129A207   332	5138018***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM			PC Info Complete	08/09/2016 12:00:00 AM	ADDRESS	34.04604	-118.26272	PC FOR TITLE 24 REMODEL OF 30TH LEVEL. REMODEL OF TWO DWELLING UNITS. INSTALLING NEW LIGHTING AND POWER. SQFT = 1235	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9095	19041-20000-52607	4204 S GLENCOE AVE	90292	11	108B153  1222	4230006010	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	06/01/2022 12:00:00 AM	ADDRESS	33.98849	-118.44124	FULL PLAN CHECK, (6) PANELS, (16) EQUIPMENTS, (17) BRANCH CIRCUITS(Building 2)1 OF 3 Electrical Application BLDG PERMIT: 19010-10000-05843ELECTRICAL  FOR BUILDING 3: 19041-20000-52578ELECTRICAL  FOR BUILDING 1: 19041-20000-52609One Electrical permit shall be issued due to there is 1 building permit(06-01-2022)This is plan check only, Electrical permit covered under: 19041-20000-52578	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9096	10041-10000-01492	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Expired	09/16/2013 12:00:00 AM	ADDRESS	34.09676	-118.29487	TI - existing church of scientology -highrise- Permit is for new ckts,, new egress, lighting and new sections rated over 600A.  P/C is for Power and Emergency/egress circuiting. ((( this permit excludes the fire pump and AC unit for fire pump room. This items will be permited under a supplemental permit)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9097	16041-10006-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS.Addition of panel, circuits, luminaire type q and 50 to total affected area.  Some circuits to be removed PC FOR CHANGES NOTED DELTA DCN-006R1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9098	19041-10000-08260	805 S MAPLE AVE Suite #A	90014	14	126A211    89	5145012027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.04078	-118.25152	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR)- T/24 ONLY IN SUITE#A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9099	16041-10003-22231	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			08/11/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.03982	-118.24098	08/11/17Changes to an approved set of plans. All changes are clouded under delta 4. Changes to single line diagram to include available fault current to existing panelboards. Also Change of engineer on record. Note: Permit is paid under PCIS#16041-10000-22231	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9100	16041-20002-04874	20754 W LUGANO WAY	91326	12	213B109   283	2701065001	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.27826	-118.58526	[5/18/16 CHANGES TO APPROVED SET. INSTALLATION OF A SOLAR READY PANEL CAPABLE OF 100 AMPS OF SOLAR BACK FEED. MODEL MC2442S1200FC ]Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (46) modules, (2) combiner boxes, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9101	19041-10000-17189	17263 W VANOWEN ST	91406	6	183B133   936	2230001012	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Issued	07/17/2019 12:00:00 AM	ADDRESS	34.19403	-118.5093	***No Permit Fee per AB1414 ***- PV2 roof mounter system, size is 39.6KWdc/38.5KWac. Scope of work includes 120 modules (Candian Solar CS6U-330P), 5 inverters (Sunny Boy SB-7.7 -1SP-US-40) , 200 A combiner panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9102	14041-10000-35688	6600 N LAUREL CANYON BLVD	91606	2	180B165   367	2322009023	P-1VL, [Q]P-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.04	Electrical	Electrical	Commercial			12/26/2014 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.19046	-118.3963	Plan check for Title 24 only. Project site is an existing commercial space (BofA). Total lighting area = 2,450 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9103	15041-20004-01901	5959 W FRANKLIN AVE	90068	4	150A191   161	5586014027	R3-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	PIN	34.1055012	-118.31956142	7/11/17changes to an approved set of plans.  changes noted delta 4. change rating of fuse to 1000A.this is plan check only.(((Plan check only.  Changes to approved set.  Transformer secondary disconnect added.  Revisions to feeder schedule.  Approval for delta-3 revisions only.)))  (((PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT TO 49 APARTMENT UNITS. NEW 800 SERVICE, PANEL UPGRADES, NEW CKTS AND NEW HEAT PUMPS FOR EVERY UNIT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9104	16041-10001-29685	1315 W PICO BLVD	90015	1	127-5A205 146	5137031018	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.04327	-118.27352	10/12/16Changes to an approved set of plans. All changes are clouded under delta 2 and delta 5. Changes include removing/adding lighting fixtures on the lighting floor plans, and relocating receptacles. Note: Permit is paid under PCIS#16041-10000-29685(((((TI OF EXISTING 1-STORY BRICK BLDG (URM BLDG) CHNAGE OF USE FROM (E) MFG/OFFICE/WHAREHOUSE TO OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9105	16041-30000-31123	17660 W BURBANK BLVD	91316	5	174B129   849	2254037020	C2-1VLD-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.17213	-118.51789	Plan check Title 24 only in existing space, remove outdoor HID lighting fixture and replace with new LED lighting fixtures. Total area: 14,835 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9106	14041-20000-15315	20480 W CELTIC ST	91311	12	210B109   100	2707026033	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Expired	07/26/2016 12:00:00 AM	ADDRESS	34.27112	-118.57951	PV1.  Install 8.925 kW roof-mounted, utility-interactive PV system.  (2) transformerless inverters with DC converters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9107	13041-10000-35667	1017 N COLE AVE	90038	13	144B185   889	5533014024	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.08941	-118.33025	PLANCHECK FOR T24 ENERGY ONLY.  NOT A HIGHRISE ACCORDING TO APPLICANT. 1957 SQFT. EMERGENCY LIGHTING.FY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9108	18041-10003-23424	5220 W CENTINELA AVE	90045	11	102B173    95	4103002016	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	33.97718	-118.37106	Changes to an approved set, all changes are clouded and marked under delta 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9109	14041-10000-20999	1225 S VERMONT AVE	90006	1	129B197   894	5078028006	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Public Safety Only			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.04827	-118.29188	New fire alarm system. 4 control panels, 108 devices, 1 fire alarm panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9110	15041-10000-31636	2735 S GENESEE AVE	90016	10	123B173  1538	5048012046	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.03023	-118.37082	PV1, INSTALL NEW 6.095 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(23) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD--US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9111	12041-10000-07904	10703 W VANOWEN ST	91605	2	183B177    62	2466017023	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			04/06/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.19414	-118.36449	CONVERT (E)PORTION OF OFFICE/WHSE TO MFG/ DELI WITH KITCHENPLAN CHK IS FOR TITLE 24 ;NEW LOADS SUM IS LESS  THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9112	15041-20001-15535	11310 N TAMARACK AVE	91340	7	210B153   101	2616017022	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	34.27551	-118.43641	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Central inverter system with 2 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9113	18041-10000-28892	5537 E YORK BLVD	90042	14	154-5A227  10	5478025002	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.1196	-118.1969	PLAN CHECK FOR TITLE 24 ONLY FOR - T.I. to an existing retail space to convert convert one tenant space into two tenant. new store front and parapet and built one ADA restroom for each tenant - 1621 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9114	19041-20000-00668	16364 W MARILYN DR	91344	12	213B137    64	2605015038	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.28406	-118.48839	Plan check for a PV1 roof-mounted PV system. System size is 11.88 kWdc/10.6 kWac and consist of (2) inverters, (36) modules, (1) load center, (1) auto-transformer, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9115	19041-10000-43422	2420 S WESTERN AVE	90018	8	123B193   418	5058015009	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.03412	-118.30876	REMOVED HID FIXTURES AND REAPLCE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9116	16041-10002-12506	1175 E 21ST ST	90011	9	120A211   109	5131009036	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.02369	-118.25356	RE-CHECK TO LOST SET OF PLANS UNDER PERMIT NUMBER 16041-10002-12506 (((PV1 rooftop solar installation on Duplex SFD, 2.15 kW AC.     (10) MODULES-HYUNDAI HiS-M250MG      (10) MICROINVERTERS-ENPHASE M215-60-2LL-S2X-IG))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9117	12041-10000-16246	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	Change to lighting for an existing retail space.  No change to load.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9118	18041-20000-48471	11975 E VARA PL	91344	12	216B125    68	2601062001	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	PIN	34.29042714	-118.52592953	Plan check for a PV1 roof-mounted PV system. System size is 10.89 kWdc and consists of (1) 7.6 kWac rated inverter and (33) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9119	13041-20000-07164	13730 W ROSCOE BLVD N2MOB	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.22149	-118.43179	Change to lighting/loads in an existing Medical Office Building (Cast Room).  NOT A STATE LICENSED BUILDING PER APPLICANT.  NOT CHECKED FOR OSHPD3.  ((North 2 Mob - Room))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9120	19041-20000-27900	14123 W NORDHOFF ST	91331	6	198B153   904	2642030900	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	07/21/2020 12:00:00 AM	ADDRESS	34.2355	-118.43975	t24 plan check only. lights and outlets only. total square footage = 12,612sfti to an existing commercial building.  adding new lighting new controls to new panels.   newly connected load <400 amps plan check for energy indoor/outdoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9121	16041-10000-29685	1315 W PICO BLVD	90015	1	127-5A205 146	5137031018	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.04327	-118.27352	TI OF EXISTING 1-STORY BRICK BLDG (URM BLDG) CHNAGE OF USE FROM (E) MFG/OFFICE/WHAREHOUSE TO OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9122	17041-10000-13368	9210 N TOPANGA CANYON BLVD	91311	12	198B101   293	2746013036	(Q)M1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.23761	-118.60578	T24 ONLY, REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 168200 SQ FT, INDOOR/OUTDOOR AREA.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9123	11041-20000-00389	23617 W ELKWOOD ST	91304	3	189B093   527	2020003028	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Expired	03/04/2013 12:00:00 AM	ADDRESS	34.21258	-118.64138	Roof mounted P.V. system with 13.16 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9124	16041-10000-00242	12027 W VOSE ST #9	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.39523	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9125	11041-20001-11514	12950 W RAYMER ST	91605	2	186B161   635	2324003020		South Valley				1233.04	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Approved	01/30/2012 12:00:00 AM	ADDRESS	34.20492	-118.41595	Changes from previously approved.  All changes are clouded on plans.  Relocated some light fixtures.Note: Previously approved submitted for reference only.*****PLAN CHECK FOR NEW 600A SERVICE, SWITCHBOARD, 200A SUBPANEL. CONSOLIDATE EXISTING 400A AND 200A SERVICE. ALL LOAD EXISTING TO REMAIN.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9126	16041-20000-38116	7511 N WILBUR AVE	91335	3	186B121   358	2104014033	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.20699	-118.54496	PV1.  Install 6.72 kW AC roof mounted grid-tied PV system.  (24) modules with Enphase S280 microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9127	17041-20000-26135	201 S RIMPAU BLVD	90004	4	135B185    80	5515008038	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.06934	-118.33094	PV1.  Install 9.27 kW CEC AC rated PV system, interconnect to 400 A 120/240V main service panel.  (32) modules with Enphase IQ6PLUS-72-2-US microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9128	15041-20000-09414	6316 N TOPANGA CANYON BLVD Ste 2120 B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and energy (first time tenant). Project scope is the installation of a new 200-amp service, (3) panels and associated loads, and a total lighting area of 2,871 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9129	14041-10000-04436	11341 N SAN FERNANDO ROAD	91331	7	210B153    15	2616019008	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	PIN	34.27564463	-118.43305166	Remove HID light fixtures and replace with new fluorescent fixtures in commercial retail space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9130	16041-10000-26107	345 N WESTMORELAND AVE	90004	13	138B197   140	5501002002	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.07753	-118.28811	METHANE MITIGATION LEVEL 4. (1) PANEL,   (24) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9131	16041-20000-33162	3854 N VALLEY MEADOW ROAD	91436	5	162B141   182	2286019014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2016 12:00:00 AM			Reviewed by Supervisor	10/07/2016 12:00:00 AM	ADDRESS	34.14087	-118.47852	Plan check for installation of roof mounted solar array on SFD. Interconnect with 400A MSP.12.8kW ungrounded system. (40) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9132	19041-10000-45802	3751 S MOTOR AVE	90034	5	120B165  1369	4314003903	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.02137	-118.40491	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9133	13041-10001-33049	523 N CHESTNUT AVE	90042	14	154-5A235 290	5493032002	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	34.11619	-118.17348	PV1 4KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(16)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]     'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9134	17041-20001-27914	12174 N CANYON HILL AVE	91342	7	216B145   241	2611043012	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.29189	-118.46602	expeditepv1install roof mounted pv system sized 4kw intefconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9135	10041-20000-02316	1151 N HIGHLAND AVE	90038	4	144B185   524	5532019002	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	03/01/2010 12:00:00 AM		Permit Finaled	10/19/2010 12:00:00 AM	ADDRESS	34.09213	-118.3388	Lighting changes to 09041-20000-21442Tenant improvement - remodel of (E) office building. Title 24 only. Emergency lighting is existing-to-remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9136	10041-10002-01626	2000 S CENTRAL AVE	90011	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	Central, South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	01/06/2011 12:00:00 AM	ADDRESS	34.02249	-118.25156	Chnages to the shell of the project - revisions to single line diagram include changes to the ampere rating of some feeder circuit breakers and corresponding panelboards; design connected load remains the sane(((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((( relocate panel p-3,  p-4 , p-6, p-7, p-8. all feeders are copper, core and warm  shell no title 24 needed. 5-4-10)))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9137	11041-20000-11890	1655 N SERRANO AVE 1-40	90027	13	148-5A193 139	5544021029	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			07/27/2011 12:00:00 AM			Corrections Issued	09/22/2011 12:00:00 AM	ADDRESS	34.1014	-118.30734	PROPOSED MIXED USE BLDG:  RETAIL/APARTMENT. (40 units) /SUBTERRANEAN PARKING GARAGE.  (NO AFFORDABLE HOUSING- ALL APT ARE MARKET RATE)**07010-10003-00202 WAS GENERATED TO REVIEW THE ZONING,  DISABLED ACCESS  AND 2008 CODE REQUIREMENTS   AS A CONDITION OF APPROVAL FOR THE PLAN CHECK EXTENSION. THE PROJECT WILL COMPLY WITH THE NEW CODE.*** THAT PERMIT WILL NOT BE ISSUED SINCE THE ORIGINAL PERMIT HAS NOT YET BEEN ISSUED..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9138	18041-20000-39752	17990 W MAYERLING ST	91344	12	216B125   163	2601018047	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.28874	-118.52513	Plan check for PV roof mounted and Energy storage system, PV System size: 13.32kW DC with 37 PV AC Modules and 1 Battery SONNEN BATTERY SYSTEM ECO 10(10KW DC, 7KW AC at 240V 1PH)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9139	16041-10001-17736	6902 W HOLLYWOOD BLVD	90028	13	147B181   194	5548006008	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM			PC Approved	09/12/2016 12:00:00 AM	ADDRESS	34.10137	-118.34033	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. UPDATED LAYOUT TO SHOW FIELD CONDITIONS. NEW CIRCUITRY FOR FITTING ROOM LIGHITNG AND RELOCATED LUMINAIRES. NO CHANGE IN T24 DOCUMENTS. REMOVED SOME RECEPTACLES FROM SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9140	12041-10000-16038	1515 N VERMONT AVE	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM			PC Approved	07/11/2012 12:00:00 AM	ADDRESS	34.09867	-118.29207	CONVERT EXISTING 2ND FLOOR LOUNGE RM. # 2113 INTO (2) OFFICES AND (2) WORK STATIONS FOR HUMAN RESOURCES SECTIONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9141	11041-10000-16729	110 N GEORGE BURNS ROAD 6th floor	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.07564	-118.38149	T.I.  Remodel of a 6th floor high rise medical building.  The remodel is taking place at the lab.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9142	14041-10001-04668	2757 S DUNLEER PL	90064	5	123B157   167	4255007006	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.03644	-118.42004	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(17) MODULES:  CNADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9143	19041-10000-30815	3032 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	12/23/2021 12:00:00 AM				PLAN CHECK FOR 800 AMP NEW SERVICE AND PANELS FOR 30 SMALL LOT SUBDIVISION SINGLE FAMILY DWELINGS. 4 APPLICATIONS UNDER 1 SET OF PLAN.(2 OF 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9144	10041-10000-18275	705 W 9TH ST BSMNT	90017	9	129A207   334	4212009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/15/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	03/23/2011 12:00:00 AM	ADDRESS	34.04607	-118.2616	CONVERT EXISTING BASEMENT STORAGE SPACE INTO AMENITY SPACES SERVING EXISTING APARTMENTS; NEW SPACES INCLUDE SPA, LOUNGE, GYM AND RESTROOMS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9145	16041-10000-22378	1624 W 59TH PL	90047	8	105B193   279	6002014010	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling	1	Dwelling - Single Family	06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	33.9866	-118.3055	PV1, rooftop solar installation 3kW AC system.   (12) RNG-250D    (12)ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9146	11041-20000-23356	601 S FIGUEROA ST	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	12/09/2011 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	energy plan check # 3750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9147	12041-10000-19618	19300 W SHERMAN WAY	91335	3	183B117    98	2130028001	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	34.20088	-118.55408	tenant improvement at the Annenberg School OFNursing plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9148	18041-20002-29197	3499 N CAHUENGA BLVD	90068	4	159B177   319	2425024011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.13268	-118.35578	Title 24 Part 6 plan check for commercial office lighting per inspection correction notice. (((Change in legal: change in address and legal from 3449 N. CAHUENGA BLVD to 3499 N. CAHUENGA BLVD, date: 09/04/2018)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9149	13041-10001-35773	13038 W SAN VICENTE BLVD	90049	11	129B137   498	4264001004	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.04835	-118.49101	CHANGES TO APPROVED PLANS. Plan check for power and energy. changes to lighting and power due to to match design of building. Changes marked by delta 1 include panel R2 designated R3 which sub feeds a new panel L3, replace luminaires with track lighting, and reduce the number of ACCUs	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9150	16041-20000-30702	1616 N POINSETTIA PL	90046	4	147B181   326	5548009035	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			08/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Issued	11/29/2016 12:00:00 AM	ADDRESS	34.10037	-118.34774	Plan check for roof-mounted solar array on an apartment building. 92kW ungrounded system (36+28+28). (327) 340W pv modules.$0 permit fee is due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9151	17041-10000-11076	189 S THE GROVE DR H-4	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR RESTAURANT TI. FULL PC FO POWER AND ENERGY. NEW TRANSFORMER AND DISTRIBUTION. REUSING SOME OF EXISTING EQUIPMENT AND REFEED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9152	17041-20000-10309	116 N ROBERTSON BLVD PLAZA B	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	34.0758	-118.38356	CHANGE OF USE FROM RESTAURANT SPACE TO COFFEE SHOP WITH OUTDOOR DINING UNDER (E) BUILDING OVERHANG.  PLAN CHECK FOR ENERGY.  BUILDING PERMIT FILED UNDER 17016-10000-06035	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9153	18041-10000-05457	1530 S ALAMEDA ST	90021	14	120A215   178	5167019035	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	08/23/2022 12:00:00 AM	ADDRESS	34.02217	-118.2392	Full plan check, TI Change of use from tire plant/warehouse to retail/whole sale (on  (E) 1-story, Type IIIB). Core and Shell only.New Service at 2500A, 208/120, 3ph, 4W with  (22) panelboards. Total area: 51,274sq.ft (indoor+outdoor)((B# 17014-10000-04731))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9154	13041-20002-33386	13029 W VENTURA BLVD	91604	2	165B161   952	2375020018	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	33.9787	-118.31759	Changes from previously approved plans.  Change include overhead service conductor and relocate service equipment to indoor.  All changes indicated by DELTA 3.Note: The permit is under the original application.*****Change to lighting, new 600 amp service for an existing restaurant.  Full plan check for power and Energy.inspector to field verify existing panel reconnection, shall have a fully rated AIC rating greater then 26kA at that point.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9155	18041-20000-19682	8409 W MELROSE PL	90069	5	141B173   440	5528002029	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.08377	-118.37357	Tenant improvement to (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9156	17041-20000-31075	13856 W ALDERGROVE ST	91342	7	231B153    95	2582007024	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.32628	-118.43574	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9157	14041-20000-03109	14042 W FOX ST	91340	7	210B153    48	2616003003	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.27621	-118.43956	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9158	19041-20000-02266	12539 W BEATRICE ST	90066	11	105B161   940	4211006026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	33.98132	-118.41472	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 427 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9159	15041-10000-26800	303 S HEWITT ST	90013	14	127-5A215  46	5163012007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	11/14/2023 12:00:00 AM	ADDRESS	34.04523	-118.23624	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS ON THE SECOND, THIRD AND FOURTH FLOOR ONLY .  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 3865	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9160	17041-30000-27800	11721 W CHAPARAL ST	90049	11	135B145   828	4402006051	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			Reviewed by Supervisor	09/22/2017 12:00:00 AM	ADDRESS	34.06666	-118.47151	Plan check New two story with basement SFD with 800A Service. Plan check only. Electrical Permit pulled under Conbination Permit Building application # 16010-30000-04453	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9161	17041-10000-11652	12223 W VENTURA BLVD	91604	2	162B165    31	2367017015	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.14351	-118.39919	PC for energy only, TI renomation to an existing Bank of America. New lighting and power. New panel, load added is less than 400 amps. Area: 5080. Building No. 17016-10000-08920.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9162	16041-20001-10343	10132 N WISH AVE	91325	12	204B133   367	2694003007	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.25508	-118.50771	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.5 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9163	19041-20000-16556	19526 W HAMLIN ST	91335	3	180B117   674	2132012006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.18876	-118.55898	Plan check for PV roof mounted system, PV system size: 11.22KW DC, 10.333KW AC with 34 PV Modules and 34 inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9164	17041-20000-45035	8937 N HANNA AVE	91304	12	195B101    62	2010021022	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.23311	-118.60683	Plan check for solar pv system w/roof-mounted array on SFD.10.12kW ungrounded system. (44) EnPhase IQ6-60 microinverters.(44) 295W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9165	18041-10000-24964	9733 N TOPANGA CANYON BLVD	91311	12	201B101   839	2727023003	[Q]CR-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.24693	-118.60718	PLAN CHECK FOR POWER FOR NEW EV SYSTEM. SYSTEM CONSIST OF 40 EV CHARGERS WITH A COONECTED LOAD > 400A TO AN EXISTING DISTRIBUTION SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9166	19041-10000-47303	7501 N MINSTREL AVE	91307	12	186B097   442	2021011019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.20652	-118.62586	[EPLAN] NEW PV1 ROOFTOP INSTALLATION WITH SYSTEM SIZE OF 7.15 KW DC/ 7.60KW AC, WITH A CENTRAL INVERTER (SE7600H), 22 MODULES (325W PANASONIC GROUP), AND 22 POWER OPTIMIZERS (P400).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9167	10041-10000-03246	1500 S OLIVE ST 6TH Floor	90015	9	124-5A207 184	5134023009	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM	02/24/2010 12:00:00 AM		Permit Finaled	04/01/2010 12:00:00 AM	ADDRESS	34.03567	-118.26482	TI IN AN EXISTING OFFICE AREA ON THE 6TH FLOOR. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS FOR RELOCATED EXISTING LIGHT FIXTURES. (EXISTING EMERGENCY LIGHTS). PERMIT IS FOR LIGHTS, SWITCHES AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9168	18041-10000-36214	10250 W SANTA MONICA BLVD space 2480	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR FIRST TIME TENANT FOR JEWELRY STORE ""AME"" POWER AND ENERGY IN WESTFIELD MALL. space 2480SCOPE INCLUDES NEW PANELS, EQUIPMENT CIRUCUITS AND LIGHTS. TOTAL AFFECTED AREA 1030 SQ.FT USING TAILORED METHOD. B# 18016-10000-30629"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9169	13041-10000-24697	12939 W HAYNES ST	91606	2	180B161   679	2326004010	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.18971	-118.41514	PV1. ROOF MOUNTED. TRANSFORMERLESS INVERTER. POWER OPTIMIZERS. UNGROUNDED SYSTEM. TWO STORIES. SYSTEM SIZE: 3.92 KW. 16 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9170	15041-10000-13382	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR POWER AND ENERGY. RENOVATION AND FIXTURE UPGRADE TO DIMMABLE LED LIGHT FIXTURES. ADDING LOADS AND 3 225 A PANELS. TOTAL AREA 18057 SQ FT.B# 15041-10000-09136.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9171	17041-10000-02364	11515 W SATICOY ST	91605	6	186B169   222	2316008012	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Issued	01/24/2017 12:00:00 AM	ADDRESS	34.20859	-118.3828	PC FOR A NEW PV SYSTEM ROOF MOUNTED, RESIDENTIAL. NEW 3.0 KW CENTRAL INVERTER AND 14 SOLAR MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9172	18041-10000-30275	8511 N FALLBROOK AVE 2nd FL	91304	12	192B097   585	2005022004	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.22466	-118.62773	TI IN AN EXISTING OFFICE AREA IN SUITE NUMBER 250 (7711 SF). T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-19836	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9173	19041-20000-28956	18441 W MONTAGE LN	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Issued	08/19/2019 12:00:00 AM				new sfd 600 amp service.  plan check for power only.  permit fees paid under building combo permit 18010-20000-05079.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9174	16041-20001-32815	11824 N MCLENNAN AVE	91344	12	216B133   630	2610002032	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	34.28476	-118.50071	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 9.8 kWac and consists of (34) modules, (2) inverters, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9175	12041-10000-08876	5601 N DE SOTO AVE 2ND FLOOR	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	TENANT IMPROVEMENT (TI):  INTERIOR REMODEL OF AN EXISTING SURGERY CENTER (NON OSHPD) ON THE SECOND FLOOR (SURGI CENTER). - LUMINAIRES AND OUTLETSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9176	19041-10000-21076	1150 S OLIVE ST 26TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.03962	-118.26181	Full PC for 26th Floor of an office TI. Scope of work inclues instaling new panels and equipment. The affected area is 18762 SQFT. Three building numbers are given for the three floors.B#1: 19016-10000-12257 (9th floor)B#2: 19016-10000-12315  (26th floor)B#3: 19016-10000-12301 (10th floor)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9177	15041-20000-07979	6303 N BEN AVE	91606	2	177B165   111	2334003057	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.18506	-118.39446	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.5KW  CENTRAL INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9178	19041-10000-27942	8906 W PICO BLVD	90035	5	132B169   910	4305014011	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.05501	-118.38589	Energy plan check for a church located on the basement of a 3-story building. Scope inlcudes new lighting and equipment with a total lighting area of 4,472-SQ FT.Note. Portion of the permit fee is paid under 18041-30000-22706	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9179	14041-20001-07045	603 W VERNON AVE	90037	9	112-5A201  27	5019010035	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.00388	-118.28425	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC. MAIN SERVICE PANEL IS RATED AT 400AMP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9180	13041-10001-36213	6261 N WHITSETT AVE	91606	2	177B165   121	2332017013	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.18485	-118.40542	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY , INTERCONNECT TO (E) 200A MAIN IN A 1-STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE IS 2.75 kW DC. (11)power  optimizers:Solaredge Op250-LV-MC4SM-2NA-Z   (11)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3000A-US}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9181	16041-10000-25861	11575 W DEHOUGNE ST	91605	2	183B169   407	2320009001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.1962	-118.38473	Plan check for T-24 only on (E) commercial building. remove HID fixtures and replace with new LED fixtures,. Total affected area; 6,700 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9182	10041-10001-01884	3401 E WHITTIER BLVD	90023	14	121-5A227  87	5188004043	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	03/16/2011 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.0278	-118.20065	CHANGE APPROVED PLAN.  CHANGE SERVICE FROM OVER HEAD TO UNDER GROUND.  ELECTRICAL PLAN CHECK FOR POWER (((((T.I. for existing gas station.  Replace switchboard, new service, add new panel, equipments, branch circuits, and new interior lighting.  Plan check for power and energy.  Per DWP Service Planner max 42KAIC.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9183	14041-20000-12972	21255 W BURBANK BLVD 3rd-4th flr	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM			PC Info Complete	06/24/2014 12:00:00 AM	ADDRESS	34.17432	-118.59446	Power and engergy plan check on 3rd and 4th floor of existing comercial office building at suite #400. Variance for 30 day demand reading has been acquired.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9184	18041-10000-02175	6100 N SEPULVEDA BLVD	91411	6	177B145   400	2242025025	M2-1-RIO, M3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.18076	-118.46437	PC for power and energy for medical optical/hearing exam rooms, offices and retail TI inside Cosco. Installing two new panels, receptacles, lights and equipment. Total area is 1518sqft. B# 17016-10000-33754.TI WITHIN 2788 SQ FT OF EXISTING 152,144 SQ FT BUILDING (COSTCO) NEW OPTICAL EXAM AND RECEPTION ROOMS, OPTICAL KIOSK, PHOTO CENTER, HEARING AID CENTER; INCLUDES DEMO, STRUCTURAL; NEW PLATFORM FOR AC UNIT ON ROOF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9185	16041-10000-18387	2101 W COLORADO BLVD	90041	14	162A223    91	5671010029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.13937	-118.21209	PC for T-24 only.  Remove HID fixtures and replace with LED fixtures. Total area: 7,254 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9186	17041-30001-04779	6821 S VICTORIA AVE	90043	8	102B185   577	4006023004	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	33.97624	-118.33248	"06/06/2017 Changes to an approved set of plan. Changes include re-feed panel ""A1"" to the empty meter. Changes apply to delta 3 only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9187	10041-10000-19209	3335 S FIGUEROA ST USC 1A	90007	8	120A203   177	5123009027	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Finaled	02/03/2011 12:00:00 AM	ADDRESS	34.02224	-118.28008	NEW RESTAURANT ( first time tenant) in new commercial building ( 73 ft high).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9188	17041-10000-41312	3701 W VISTA DEL VALLE DR	90027	4	156B197     2	5593002906	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			PC Info Complete	02/27/2018 12:00:00 AM	ADDRESS	34.12434	-118.28432	PC FOR SERVICE TO 600A 1PH 120/240 FOR PUBLIC WORK PROJECT. SCOPE INCLUDES NEW MAIN SWITCH BOARD AND CIRCUITS. B# 17020-10000-03113      17030-10000-07508	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9189	18041-10000-10612	3241 N FIGUEROA ST	90065	1	142-5A221  26	5446009028	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.08636	-118.21941	PC FOR POWER AND ENERGY FOR A NEW STARBUCKS. SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA  2988 SQ.FT.B#18016-10000-08706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9190	19041-10000-22752	2905 W EXPOSITION PL Unit #1	90018	10	117B185    13	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.02038	-118.3277	Plan check for a 3KW AC/ 2.6KW DC PV2 roof mounted system with (1) inverter and (8) modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9191	16041-30001-28769	700 S FLOWER ST # G740	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM			PC Approved	02/23/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	02/23/2017 Changes to an approved set of plans. Changes have been clouded and marked as Delta 3. Changes have been made to the emergency lighting.*****Previous Work Description*****PC FOR T24 ENERGY ONLY. NEW LIGHTING IN RETAIL TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9192	18041-10001-37667	1533 N SCHRADER BLVD Admin Bldg	90028	13	147A187    32	5547018901	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.09901	-118.33257	CHANGES TO AN APPROVED SET OF PLANS, CHANGES ARE UNDER CLOUDED AREA. SCOPE OF WORK INCLUDES RELOCATION OF TRANSFORMER/ PANEL AND UPSIZING TRANSFORMER SIZE TO 75KVA.PC ONLY____________________________________________New emergency temporary shelter for the homeless consisting of two separate state certified modular buildings-Admin Bldg; Hygiene Bldg  and new constructed building- Membrane Bldg-.The branch circuits inside the Admin Bldg and Hygiene Bldg will be part of the state certificationThis application is for the service equipment and the administration building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9193	18041-10002-40295	7843 N LANKERSHIM BLVD	91605	6	189B169   517	2310025***	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	Change to approved set by modifying the single line and adjustment on the floor plan. All changes under delta-2 only.(((NEW COMMERCIAL  ROOFTOP SOLAR SYSTEM CONSIST OF 42 MODULES (HANWHA Q PEAK-L-G4.2 365) AND 21 MICROINVERTERS (AP YC-600).  SYSTEM SIZE IS 15.33KWdc and 12.6KWac)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9194	13041-10000-18169	350 S GRAND AVE B-5	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	PIN	34.05160512	-118.25169569	TENANT IMRPOVEMENT , TITLE 24 LIGHTING, EMERGENCY LIGHTING INCLUDED. SCOPE OF WORK IS 1036 SQ FOOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9195	10041-10000-13441	545 S FIGUEROA ST	90071	9	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.0514	-118.2582	NEW DISTRIBUTION BOARD TO SUPPLY HEATERS, FILTER PUMPS AND NEW CIRCUITS AT AN ATHLETIC CLUB	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9196	18041-20000-00571	20701 W CLARK ST	91367	3	174B109   675	2151031047	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.16905	-118.58295	PV1.  Install 14.04 kW roof mounted grid tied PV system.  (39) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9197	16041-20000-05953	13274 W FIJI WAY #140	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	33.97902	-118.43558	Plan check T-24 only for office T.I. existing space. Total area 1,121 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9198	17041-20000-37014	767 S ALAMEDA ST ste 144	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Issued	10/16/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9199	13041-20001-10856	16812 W MOONCREST DR PV1	91436	5	165B133   392	2291010027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.14735	-118.4994	IONSTALL ROOF MOUTNED PHOTO VOLTAIC SYSTEM 9.78 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9200	17041-20000-07000	8621 N PENFIELD AVE	91306	3	192B113   739	2782011***	(T)(Q)RD4-1XL	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.22669	-118.56904	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (18) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9201	14041-10000-13371	600 WORLD WAY TERMINAL 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM			Corrections Issued	05/20/2014 12:00:00 AM	ADDRESS	33.9427	-118.40223	PLAN CHECK FOR ENERGY FOR LAX TERMINAL 6 EXISTING OFFICE RENOVATIONS. NOT A FIRST TIME TENANT PER APPLICANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9202	11041-10000-23982	5450 W PICO BLVD	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.04862	-118.35714	New Commercial building.  New 1200A service and circuits.  Plan check for POWER and ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9203	15041-10000-02756	2824 E 12TH ST	90023	14	120A221   189	5169009018	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.02111	-118.2185	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 1984 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9204	11041-20000-20205	10960 W WILSHIRE BLVD Ste # 2100	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	09/22/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	T.I.  Remoel of the lighting fixtures in suite 2100.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9205	15041-20001-19675	7716 N MORELLA AVE PV1	91605	6	189B169   904	2317007042	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM			PC Approved	09/04/2015 12:00:00 AM	ADDRESS	34.21094	-118.38989	Plan check for PV roof mounted system. System size: 9.9kW with 30 modulesn and 1 inverter (9.9kw)Standard plan is being use. Note: Soalr clearance refer to Application # 15041-20000-19675{{{{{{{Install roof mounted photovoltaic solar system.  9.81   KW system.The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9206	14041-20001-01398	7734 N SALE AVE	91304	12	189B097  1032	2013017004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.21118	-118.6184	EXPEDITE FEES ONLY<<<New rooftop PV system using two UNGROUNDED inverters for an existing single family dwelling.  Service Panel Upgrade is not a part of this permit and is to be pulled SEPARATELY.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9207	15041-10004-32877	1640 S SEPULVEDA BLVD 103 & 104	90025	5	129B153   699	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.04838	-118.44468	Changes to approved set. This is PC only for T-24. Permit under 15041-10000-32877.(Supplemental to PCIS# 15041-10001-32877)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9208	18041-30000-43873	854 N NAPOLI DR	90272	11	126B133    91	4408016005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM			Reviewed by Supervisor	12/26/2018 12:00:00 AM	ADDRESS	34.04346	-118.50823	PC FOR (N) 2 STORY SFD  W/BASEMENT AND 3 CAR GARAGE AT GROUND FLOOR LEVELSCOPE INCLUDES NEW 600A 1PH 120/240V SERVICE .16010-10000-01928	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9209	18041-10002-39532	950 W 190TH ST	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Permit Finaled	09/02/2020 12:00:00 AM	ADDRESS	33.85814	-118.29219	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE REVISIONS TO LOAD CALULCTIONS AND FLA RATINGS OF VARIOUS MOTORS. ALL CHANGES ARE CLOUDED UNDER DELTA 8. ALSO CHANGING CONTRACTOR FOR PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9210	18041-10000-07486	17200 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Info Complete	03/12/2018 12:00:00 AM	ADDRESS	34.20827	-118.50773	PC for T24 only for replacement of indoor&outdoor existing fixtures with LED fixtures for Chase bank. Egress lighting is not part of the scope.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9211	10041-20000-23029	928 S WESTERN AVE #153	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	08/05/2011 12:00:00 AM	ADDRESS	34.05485	-118.30886	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9212	16041-20000-19166	3411 E ESTRADA ST	90023	14	120A225   371	5190017037	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Expired	07/12/2018 12:00:00 AM	ADDRESS	34.02081	-118.20481	Plan check for PV roof mounted system. system size: 5.0kW with 18 modules and 1 inverter(5.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9213	15041-10000-37560	909 S SANTA FE AVE	90021	14	123A217   108	5166012010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.03228	-118.23021	Energy plan check for a commercial T.I;  Changing a tasting room to a storage room with new lighting and receptacles. Total area is 254-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9214	18041-20001-35456	5217 N ELLENWOOD PL	90041	14	163-5A221 243	5671021023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.14139	-118.21836	Revisions to approved set.  Change of module from Solarcity Standard SC325 to Solarcity Standard SC330.  PV DC kW rating adjusted to 5.94 kW. $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((Plan check for PV roof mounted system and battery back up, PV system size: 5.2kW with 18 modules and 1 inverter(5.2kW), Tesla PowerWall 2.0 13.5kWh)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9215	15041-10000-25611	15232 W FOOTHILL BLVD Unit 151	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.32292	-118.46695	PV1, INSTALL 3.92 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(12) MODULES: SUNPOWER SPR327NE(1) INVERTER: ABB PVI-3.8-OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9216	15041-10000-42384	6053 W CENTURY BLVD #603	90045	11	093B169   305	4124030902	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	33.94648	-118.38998	"T-24, TENANT IMPROVEMENT PROJECT ON THE SIXTH FLOOR OF A ""B"" OCCUPANCY  OFFICE BUILDING, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9217	12041-10000-20293	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.04804	-118.46227	REMODEL EXISTING OFFICES  ON 9TH FL-NO CHANGES IN THE EMERGENCY SYSTEMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9218	15041-20000-31338	7925 N GREENBUSH AVE	91402	6	189B157   509	2301022028	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.21468	-118.42684	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZEl 7.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9219	11041-10000-24490	1828 E CESAR E CHAVEZ AVE	90033	14	130-5A221 325	5174008022	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	34.05014	-118.21571	New shell only for a 6 story Medical Office Building and Parking structure.  Additional plan check fees under submittal 2 to be paid later by applicant.  Variance will be filed to seperate Fire Alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9220	17041-10001-25817	1691 W ADAMS BLVD	90007	8	123B197   818	5054004031	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.03288	-118.29995	DELTA 4 TO RETAIL AND GAS STATION. CHANGE INCLUDE ADDING A CONTACTOR TO GASOLINE SYSTEM 100AMP PANEL AND ADDING AN ISOLATED GROUND TO PANEL P2. CHANGE IS IN SHEET E1.0 ONLY . ORIGINAL P# 17041-10001-25817.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9221	12041-20000-00768	10250 W SANTA MONICA BLVD #690C6	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM	01/12/2012 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to existing space.  Install indoor general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9222	17041-10000-32353	8500 W BEVERLY BLVD STE 784	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC for power and energy for  retail TI. Total load over 400A.  Installing new panels, circuits and equipment. Building# 17016-10000-24524. Total area of 8089sft. Low voltage is not subject to this plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9223	13041-10000-07679	9301 N TAMPA AVE SP # 52	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	INTERIOR & EXTERIOR TI OF (E)  RETAIL SPACE (10211 S.F.) INCLUDING DOORS, PARTITIONS, CEILING & FIXTURES.( INSIDE  THE MALL).-PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9224	10041-20000-21716	350 S BIXEL ST	90017	1	132A209    99	5152014038	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM	11/01/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.05673	-118.26007	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9225	13041-20001-32864	12522 W MILBANK ST	91604	2	168B161  1111	2362028018	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.15308	-118.40603	((Expedite fees))PV1 TRANSFORMERLESS INVERTER. USING SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 7.395KW. 29 PANELS AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9226	14041-10001-10227	2842 S MOTOR AVE	90064	5	126B165   778	4308012008	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.04015	-118.40446	Expedited RSES plan check per applicant request.{{PV1.Install 7.25 kW DC roof-mounted solar array on a 2 story-house, interconnect with main service panel.(1) Transformerless inverter: SOLAREDGE #SE6000A-US-ZB-U(29) Modules: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9227	19041-10000-19127	10250 W SANTA MONICA BLVD 1970	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Issued	07/10/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	T-24, PC for energy only. T.I. to existing retail store. Scope includes new lights and receptacles. Total affected area is 5227 Sq. Ft. B#19016-10000-15041	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9228	16041-20000-06637	8662 N COMANCHE AVE	91306	3	195B113   582	2781016001	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.2279	-118.57237	PV1.ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW  CENTRAL INVERTER STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9229	19041-20000-42796	10812 N DELCO AVE	91311	12	207B109   109	2707005029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.26681	-118.57907	PV1.  Install 9.99 kW DC roof mounted grid tied PV system.  (27) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9230	16041-10000-06474	300 S SANTA FE AVE SPACE B	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	PC FOR POWER AND ENERGY. 6 STORY BUILDING. 1ST TIME TENANT BOOKSTORE RETAIL IN SPACE B, GROUND LEVEL. TOTAL AREA 2289 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9231	18041-20001-44874	17019 W DEARBORN ST	91325	12	198B133   461	2692021025	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.23749	-118.50319	12-11-2018 Changes to an apporved set of plan, Changes include change main breaker to 175 A Center fed panel.Plan check onlyFees $0.00 due to california senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9232	10041-10000-16339	7056 FOOTHILL BLVD	91042	7	202-5A201 562	2564003018	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM			PC Info Complete	08/19/2010 12:00:00 AM	PIN	34.24780127	-118.28532063	title 24 for a one story auto repair shop. no emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9233	18041-20000-16988	21250 W CALIFA ST #115	91367	3	174B105    16	2149002018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			PC Info Complete	06/14/2018 12:00:00 AM	ADDRESS	34.1769	-118.59414	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to a place of assembly. Total lighting area = 5,600 sq. ft.Note: Building application has been generated under 15016-20000-23077	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9234	14041-10000-05443	7811 N LANKERSHIM BLVD	91605	6	189B169   715	2310025035	[Q]C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.21242	-118.38799	Remove HID light fixtures in existing commercial show room space and replace with fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9235	15041-10001-01532	3412 S KEESHEN DR	90066	11	117B153   976	4248020021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	ADDRESS	34.01417	-118.43609	Expedited per applicant requestinstall roof mounted solar array, interconnect with main panel. system size: 5.1 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9236	11041-10001-11307	879 W 190TH ST SUITE#110	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM			Corrections Issued	06/13/2011 12:00:00 AM	ADDRESS	33.85951	-118.28963	T24 for Tenant improvement Farmers Insurance Co. EPC is for T24 & Emergency lights. (Permit was issued under# 11041-90000-11307)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9237	18041-10000-38016	1630 W ANAHEIM ST	90710	15	033B193   953	7411012091	[Q]C1.5-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.78567	-118.30526	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9238	14041-20000-02227	19530 W NORDHOFF ST	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.23526	-118.55901	PC FOR POWER AND ENERGY. EXISTING RETAURANT REMODEL. EFFECTED AREAS INCLUDE KITCHEN AND DINNING. PLACE OF ASSEMBLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9239	13041-20000-24379	7221 N CLYBOURN AVE	91352	2	183B177    28	2410021008	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM			PC Approved	09/06/2013 12:00:00 AM	ADDRESS	34.20194	-118.36251	CONSTRUCTION OF PHOTO STUDIO. EMPTY WAREHOUSE AND PARKING GARAGE. PC FOR T24 ENERGY ONLY. TOTAL AREA 3400 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9240	16041-20000-26388	16325 W MALDEN ST	91343	12	192B137    91	2689026006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.22588	-118.48816	Plan check for PV roof mounted system. System size: 3.0kW and 1 inverter(3.0kW) with 13 modules. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9241	13041-20001-14498	10224 W CHARING CROSS ROAD	90024	5	138B157   124	4359021005	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.07805	-118.42949	Relocation of service. Removal of new generator from scope of work. No changes to load.RELOCATING 600A SERVICE AND GENERATOR UPGRADE FOR SINGLE FAMILY DWELLING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9242	17041-10000-11117	9023 N SEPULVEDA BLVD	91343	7	195B145    77	2654003011	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.05	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.23429	-118.46787	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  10500 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9243	15041-20001-39016	6510 W HOLLYWOOD BLVD	90028	13	148-5A187 181	5547016003	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.10143	-118.33155	02/05/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms. *****Previous Work Description*****CHANGE OF USE FROM RETAIL TO RESTAURANT.PC FOR ENERGY ONLY, TOTAL AREA 1,077 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9244	14041-20000-00504	7839 N VARIEL AVE	91304	3	189B105   380	2109017007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.21319	-118.59299	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9245	17041-10000-11742	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Info Complete	05/04/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC for power and energy for new circuits, equipment and panelboards for upgrading security lanes and new IT room in Airport. Total area is 245sqft.building #17016-10000-09001	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9246	13041-10000-27410	3540 S FIGUEROA ST	90007	9	118-5A201   7	5123022031	USC-1B	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.01945	-118.28133	REPLACING EXISTING FIRE ALARM PANEL AND ANNUNCIATOR TO EXISTING FIRE ALARM SYSTEM IN HIGH RISE BUILDING. 11 STORIES, WITH ROOF, FULLY-SPRINKLERED SYSTEM. ADDING 15 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9247	17041-10000-03908	10250 W CONSTELLATION BLVD 7th floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI TO 7TH FLOOR. PC FOR T24 ENERGY ONLY. NEW LIGHTING AND OFFICE PLUGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9248	15041-10000-19429	855 S WALL ST 2nd FLR	90014	14	126A211   208	5145011015	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.03918	-118.2517	Energy plan check for a bank (Wallis ) T.I located at the second floor of a commercial building; Scope include new lighting, equipment and receptacles. Total area is 2419-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9249	15041-20000-25017	14006 W RIVERSIDE DR #76	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only retail T.I. . Total indoor area: 2,307 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9250	16041-20002-26751	10534 W SANTA MONICA BLVD 1-9	90025	5	132B157  1078	4317004016	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM			PC Approved	07/16/2018 12:00:00 AM	ADDRESS	34.05456	-118.42769	7.16.2018 - Plan check for change to approved set.  Reduction of elevator HP rating from 40 HP to 15 HP.  ======10.20.2017 - Plan check for changes to approved set. Adding 30HP fire pump and garage supply fan (GSF-1). Adding fire dampers. Service equipment boards MS1 and MS3 are fed through bussing instead of feeders. Changes clouded delta C.======plancheck for power and energy.  new 37 unit apartment 5 story over 3 subterranean parking. [ FEES ARE BASED ON PRECUT CHECK, PLANCHECKER TO RECALCULATE].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9251	10041-10000-17651	1205 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.05111	-118.2267	Solar voltaic system installed on the roof of the building.  Consists of  13 modules,  13 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9252	10041-10000-14631	1412 S BUTLER AVE BLDG III	90025	11	129B149   177	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.04834	-118.45366	NEW SERVICE, PANELS AND CIRCUITS FOR 31 UNITS APARTMENT BLDG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9253	10041-20000-05392	18701 W DEVONSHIRE ST	91326	12	204B121    71	2728028023	C2-1VL, QC2-1VL, QP-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Finaled	04/26/2010 12:00:00 AM	PIN	34.25808925	-118.53932955	CHANGE OF USE OF TENANT SPACE  FROM COFFEE SHOP TO RETAIL energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9254	18041-20000-43060	10777 W SANTA MONICA BLVD	90025	5	129B153    23	4325030006	[Q]RD1.5-1-O, [Q]RD1.5-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM			PC Info Complete	03/29/2019 12:00:00 AM	ADDRESS	34.05147	-118.43332	TI to (E) house of worship. Replacement of feeders and distribution panels, power and lighting updates to levels 1 and 2, and new site lighting.  Scope includes renovation work to assembly halls.Building permit under 18016-20000-36406.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9255	10041-20000-13369	633 W 5TH ST #3330	90071	9	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM	07/19/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check T-24 general/emergency lighting for suite #3330 at US Bank Tower	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9256	16041-10000-22432	7285 W MULHOLLAND DR	90068	4	156A181   621	2428018008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.12018	-118.3513	PC FOR SFD WITH NEW 800A SERVICE. FLOOR PLANS PROVIDED FOR FULL REVIEW.  BUILDING PERMIT - 14016-20000-21070 - ELECTRICAL FEES COLLECTED UNDER THIS MASTER PERMIT. CODE ENFORCEMENT CASE#  655522, Supplemental electrical permit includes equipment on single line diagram per inspector's request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9257	17041-10000-00317	6382 W 6TH ST	90048	5	135B173   697	5510025018	R2-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.0655	-118.36777	PV, INSTALL NEW 5.40 KW DC/4.80 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A DWELLING HOUSE.(15) PANELS: SPR-X22-360-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9258	13041-10000-27798	2049 S CENTURY PARK EAST #3180	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY. TI (E) OFFICE. STE 3180. GEN HIRISE. <400A per applicant. videoconference room, 2 offices, and adjoining corridor. (changes on plan 10/7/2013 - clarification of luminaire type on plans, T24 lighting controls to show multiscene programmable)T. Lighting in a videoconferencing studio: Up to 2.5 W/ft� of lighting in a videoconferencing studio provided the videoconferencing lighting is in addition to and separately switched from a general lighting system; all ofthe lighting is controlled by a multiscene programmable control system; and the video conferencing studio has permanently installed videoconferencing cameras, audio equipment, and playback equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9259	15041-10000-36469	805 E VERNON AVE	90291	11	111B145   911	4240016061	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	33.9992	-118.46572	PV1 roof mounted installation to a single family home. (1) inverter: 4.275 kw/5.0kwac, (15) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9260	19041-10000-18536	4414 W SANTA MONICA BLVD	90029	13	144A201    35	5539001001	CM-1VL	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.09073	-118.28506	Replace fluorescent troffers with new LED retrofit kits (Indoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9261	13041-20000-14308	7850 N HASKELL AVE	91406	6	189B141   186	2206001017	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.21333	-118.47474	Change to lighting and receptacles in an exsting low-rise office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9262	12041-10000-15453	1642 N LAS PALMAS AVE	90028	13	148-5A185 170	5547014018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.10104	-118.33601	New fire alarm system for a night club bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9263	14041-20000-17035	515 S FIGUEROA ST #2050	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Issued	09/24/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	T.I. to an existing high rise building on the 20th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9264	14041-20001-12014	12650 W SANDHILL LANE Unit 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	33.9774	-118.4142	Fee for expedite only.****Roof mounted PV system with system size 1.38KW.  Using transformerless inverters.  This part of a series set of submittal.  This PV system to interconnect to common service.  This is project 2 of 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9265	15041-10000-40924	4323 W DON DIABLO DR	90008	8	114B181   203	5031007014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.00938	-118.34924	PV1, ROOF MOUNTED SOLAR SYSTEM WITH (31) KYOCERA #KU255-6XPA MODULES AND (1) INVERTER 6000KW-AC, ABB #PVI-6000-OUTD-US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9266	15041-20000-35909	6749 N FALLBROOK AVE #619	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.1925	-118.62407	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement (change of use from retail to beauty salon). Total lighting area = 5,989 sq. ft.Note: Building application has filed under 15016-20000-23404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9267	16041-10001-13189	2656 N GRIFFITH PARK BLVD 6	90039	4	150A205    85	5434037020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.10657	-118.27197	PC FOR CHANGES TO APPROVED SET OF PLANS. ALL CHANGES NOTED DELTA 2 REVISION. CHANGE IN LIGHT TO 59 WATT TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9268	11041-20000-07866	10850 W PICO BLVD #M2	90064	5	126B157  1663	4256001025	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.03983	-118.42857	T.I. to existing restaurant.  Install general/emerngency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9269	18041-20000-11676	12033 N CARABELA CT	91326	12	216B109   297	2701083019	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29154	-118.58308	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac/5.03 kWdc and consists of (15) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9270	15041-20003-23703	15800 W STRATHERN ST Bldg. 3	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	34.21559	-118.47752	(12/29/2016)changes to an approved set of plans to reflect field conditions.  Sheet E3.2 only.this is plan check only.8.15.2016 - Plan check for modifications to approved set (delta-6 revisions). Revision of plan for building 3. New/revised lighting, equipment, and circuits. Recheck power and energy. Some (E) equipment wasn't shown on originally approved plan, plan has been revised to reflect field conditions (for example T2).APPROVAL FOR DELTA-6 AS-BUILT CHANGES ONLY.  =====Plan check for power and energy.  Total area = 1,035 sq. ft. (indoor) + 400 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9271	10041-20000-23120	11657 W SHERMAN WAY	91605	6	183B169   111	2316030006	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	02/03/2011 12:00:00 AM	ADDRESS	34.20136	-118.3864	Plan check T24 energy for Subway TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9272	11041-20000-03544	12661 W BRANFORD ST REC ROOM	91331	6	201B161   647	2624013002		North Valley				1048.10	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.244	-118.40933	Install general/emergency lighting for indoor and outdoor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9273	19041-20001-36592	22140 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18618	-118.6099	Expedite per applicant requet . Plan check for PV roof mounted system, system size: 30.015KW DC, 26.7KW AC CEC with 69 PV Modules and 2 inverters(14.4KW)Applicant request: plan stay %%%%%%%%%%%%%   Van Nuys     %%%%%%%%%%Note: 12 Buildings in 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9274	16041-10000-27719	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING 6 STORY BUILDING OFICE/RETAIL/RESTURANT BUILDING. SCOPE INCLUDES 510 FA DEVICES, 1 FA PANEL, 1 CONTROL PANEL, AND 1 COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9275	16041-10000-14153	1888 CENTURY PARK EAST 14TH FLR	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	PIN	34.06160176	-118.41389445	TI TO AN EXISTING COMERCIAL BUILDING. ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL 2220SQFT. SCOPE OF WORK TO PERFORMED TO THE 14TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9276	14041-10000-30734	8720 N BALBOA BLVD	91325	12	195B133   419	2688041038	C1-1VL, C2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	04/27/2015 12:00:00 AM		Issued	04/27/2015 12:00:00 AM	ADDRESS	34.22939	-118.50239	Bank tenant improvement.  Plan check for energy.  1,970 sq. ft.  T24-exempt exterior lighting for ATM kiosk included.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9277	16041-10000-40352	19325 W LONDELIUS ST	91324	12	195B117   110	2783025103	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.22999	-118.55461	Installation of a new fire alarm to an exsisting 4 story building hotel. Installing 219 Fire alarm devices, and 2 Fire alarm panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9278	16041-10000-42599	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Closed	06/22/2021 12:00:00 AM	ADDRESS	34.05715	-118.41482	PC FOR POWER ONLY. TEMPORARY POWER FOR A CONSTRUCTION SITE, SCOPE INCLUDES PHASE 1-ABATEMENT, AND PHASE 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9279	16041-20000-35339	2011 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Closed	09/27/2017 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for power only. Project site is an existing commercial building. Project scope is temporary power for existing electrical equipment. Temporary power equipment includes medium voltage equipment. Temporary power will be in place while electrical work permitted under 15041-20000-02002 is completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9280	16041-10000-45433	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	33.97808	-118.40726	Plan check for power and Title 24, build out of a 4 level office building - Google Spruce Goose. Scope of work is under note 23 on the single line diagram.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9281	15041-20000-01159	6239 W FOOTHILL BLVD	91214	7	198B205   194	2571006024	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	PIN	34.24137572	-118.26693145	TI to existing commercial building. Plan check for energy only. Adding new lighting, controls, and panel. Total sqft. 1042.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9282	14041-10000-34364	23155 W MARIANO ST	91367	3	171B093    63	2042007018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Expired	01/05/2017 12:00:00 AM	ADDRESS	34.16844	-118.63171	PV1 roof mounted PV system size: 8.3 kW  with 2 inverters and 24 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9283	17041-10000-07412	3121 W OLYMPIC BLVD 105	90006	10	129B193   271	5080024027	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.05277	-118.30387	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RESTUARANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2705 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9284	18041-10001-22737	70 S FREMONT PL	90005	10	132B185   361	5090020014	RE20-1	Central	Wilshire	Greater Wilshire		2127.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/29/2018 12:00:00 AM	ADDRESS	34.05874	-118.32708	Expedite per applicant request(((Plan check for a 7.6 KW AC PV1 roof mounted system with (27) modules, (1) 7.6KW inverter and (1) storage battery system interconnecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9285	16041-20000-33881	1611 S WESTERN AVE	90006	10	126B193   319	5073012031	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.04297	-118.30926	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 4,860 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9286	17041-10000-38814	16216 W RAYMER ST	91406	6	189B137    20	2205029033	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.21765	-118.48623	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 23100 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9287	13041-20002-22749	6411 N SEPULVEDA BLVD 2B-2C	91406	6	180B145   763	2234016013	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	PIN	34.18706228	-118.46668363	Modification to approved set of plans to change 5 lights from 3-bulb to 2-bulb.<<<Change of use to Medical.  Full Plan Check for power and Energy.  Building is State Licensed, MUST BE Checked for OSHPD3.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9288	16041-20000-06899	5555 W MELROSE AVE 4th Floor	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM			PC Approved	02/26/2016 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for Title 24 only. Project site is a portion of the 4th floor of an exising commercial building. Project scope is a tenant improvement. Total lighting area = 690 sq. ft.Note: Building permit has been pulled under 16016-10000-01043	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9289	17041-30000-42701	307 N FIGUEROA ST #307	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	33.77217	-118.27886	Plan check for Title 24 only in existing wearhouse and office. Total lighting area: 6700 sq ft. Building application number 17016-10000-29212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9290	15041-10000-30939	11455 W BURBANK BLVD BLDG A&B	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	TI to an exisiting religious assembly site (2-story building), Church of Scientology-Areas A &B. All equipment is new except the service. Full Plan Check for power and energy. Total Sq ft = 65,971.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9291	17041-10000-10741	5352 N AUCKLAND AVE	91601	4	171B177   150	2417006010	M1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Issued	04/04/2017 12:00:00 AM	ADDRESS	34.16801	-118.36032	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 4,000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9292	17041-10000-25401	1147 N VINE ST	90038	13	144B185   551	5533007033	C2-1D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Issued	07/26/2017 12:00:00 AM	ADDRESS	34.09215	-118.3268	PLAN CHECK FOR FIRE ALARM SYSTEM - SYSTEM CONSIST OF 101 DEVICES AND ONE FIRE ALARM CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9293	19041-10001-27893	19546 W ELKWOOD ST	91335	3	189B117   765	2105009012	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM			PC Approved	07/29/2019 12:00:00 AM	ADDRESS	34.21265	-118.55971	Expedite per applicant request:PV1. NEW ROOF TOP SOLAR SYSTEM CONSIST OF 34 MODULES (TRINA SOLAR 300), OPTIMIZERS (SE P300) AND A CENRAL INVERTER (SE11400H-US). SYSTEM SIZE IS 10.2 KWdc AND 11.4KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9294	13041-10002-29795	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	((6/30/2015: ADDING 73 DEVICES TO FIRE ALARM SYSTEM))))Installation of new fire alarm system in Loyola Marymount University Life Science tenant improvement to meet proper coverage per NFPA 72.  1 new fire alarm control panel and 324 devices. (conduit only pulled for P1,2,3 on 10/24/2013)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9295	14041-20000-09565	4515 N ENCINO AVE	91316	5	165B129   105	2290019006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.15154	-118.51415	this is most updated designPV1 SINGLE FAMILY DWELLING. TOTLA SYSTEM SIZE 14.8KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING 3 CENTRAL INVERTERS. USING POWER OPTIMIZERS(($0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9296	19041-10000-04027	1 E WASHINGTON BLVD	90292	11	103-5A145  26	4226023006	C1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	33.97931	-118.46683	PLAN CHECK FOR T24 ONLY, INTERIOR TENANT IMPROVEMENT TO EXISTING RESTAURANT. NEW SERVICE AT 200A, (2) NEW PANELBOARDS, NEW LIGHTS AND POWER. TOTAL AREA APPROX: 1455SQ.FT(B# 18016-10000-41191)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9297	16041-10000-03176	22915 W VICTORY BLVD	91307	12	180B097   434	2038040031	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Issued	04/13/2016 12:00:00 AM	ADDRESS	34.1866	-118.62549	FULL PC TO AN EXISTING RALPHS MARKET. SCOPE INCLUDES ADDING/RELOCATING LIGHTS IN THE EXISTING FOOD PREP AREA AND IN THE NEW STARBUCKS KIOSK AREA. TOTAL CONNECTED LOAD> 400A. TOTAL AFFECTED AREA IS 2000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9298	14041-10000-31176	6245 W LEXINGTON AVE	90038	13	144B189   321	5534002023	C2-1D	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.09266	-118.32587	Energy plan check for a T.I retail building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9299	17041-20000-19469	4647 S PURDUE AVE	90230	11	111B161   758	4217021021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	33.9986	-118.40848	Plan check for the addition of (4) modules and (4) micro-inverters to an existing PV1 roof-mounted PV system. System addition is 1 kWac. Total system size is now 3 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9300	13041-10000-21162	3668 S 3RD AVE	90018	10	120B189  1612	5042005023	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM			PC Info Complete	08/07/2013 12:00:00 AM	ADDRESS	34.02092	-118.31998	Changes to already approved PV system under no. 13041-10000-02689.  The changes is to the PV modules from REC245PE to REC 250PE system now is 3.5 KW no other changes.   This is plan is for plan check only permit is existing	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9301	13041-10000-24290	4900 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.09786	-118.29626	Replacement of emergency generator, addition of life-safety ATS, panels and emergency lighting medical office building (6 story low rise building)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9302	10041-20000-20052	1099 S GRAND AVE	90015	9	127-5A207 265	5139008001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/08/2010 12:00:00 AM	10/08/2010 12:00:00 AM		Permit Expired	12/24/2012 12:00:00 AM	ADDRESS	34.04179	-118.26214	Change from 400 amp to 800 amp for temporary service.  Plan check for power only.NOTE: Previous 400 amp permit under 10041-10000-18679	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9303	15041-20000-10709	12819 W DAVENTRY ST	91331	7	213B161   248	2527017001	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.28266	-118.41261	Plan check for PV1 roof-mounted PV system. System size is 4.1 kWac and consists of (19) modules, (19) micro-inverters, and (1) subpanel. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9304	11041-20000-19542	2401 W WASHINGTON BLVD	90019	10	126B189   911	5073020001	[Q]CM-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	11/21/2011 12:00:00 AM	PIN	34.04012563	-118.31465976	Plan check for 600A service upgrade to existing building. All tenants are occupied and branch ckts are existing to remain. New feeders and panels. Site in methane zone, no underground penetration for electrical work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9305	12041-10000-15891	14024 W OSBORNE ST	91331	6	195B153   260	2640016025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00, 1198.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.23313	-118.43803	New McDonald's restaurant with 138 occupancy load and new 1000A Service.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9306	15041-20002-19153	11119-11123 W BURBANK BLVD	91601	2	174B173   942	2337031022	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.17232	-118.37324	Changest to an approved set of plans. Adding new lighting and receptacles for all 3 tenant spaces. Plan check for energy only. Total sqft. 3,053.(((Plan check for power only. Project site is an existing commercial building. Building has (3) tenant spaces, each with its own address (11119, 11121, and 11123 Burbank Blvd). Project scope is a 600-amp service upgrade, the installation of (3) tenant panels, and (1) A/C unit for each. Title 24 is NOT part of this plan check.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9307	16041-10000-27218	5663 N OAKDALE AVE	91367	3	174B113   243	2153017016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.17404	-118.56582	PV1, INSTAALING NEW 7194 W DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLR FAMILY HOUSE.(22) MODLES: SUNPOWER SPR-E20-327-C-AC(22) MICROINVERTERS: THE SAME BRAND	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9308	13041-10000-24843	23442 W BALMORAL LANE	91307	12	183B093   320	2028020009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.19754	-118.63737	PV1 8.085KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-3.0-OUTD-US and PVI-3.6-OUTD-US ] [( 33) MOD: Hanwha {HSL60P-PA-0-2445TW}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9309	19041-20000-51633	3525 E 16TH ST	90023	14	117A225   181	5192007019	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM			Reviewed by Supervisor	01/15/2020 12:00:00 AM	ADDRESS	34.01515	-118.20193	POWER AND ENERGY PLAN CHECK, NEW 1200A SERVICE, (12) PANELS, A 300 KVA TRANSFORMER, AND T24 INCLUDED TOTAL SQUARE FOOTAGE = 7552 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9310	12041-20000-10234	22115 W ROSCOE BLVD	91304	12	192B101   520	2010023034	(T)(Q)C1.5-1, C2-1L, P-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	34.21979	-118.60892	fire alarm topanga west guest home	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9311	16041-20000-17970	16740 W ARMSTEAD ST	91344	12	213B137   289	2610011001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.28198	-118.49712	PV1.  Install 6 kWac roof-mounted PV system.  Transformerless central inverter with (21) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9312	15041-20001-39533	635 S MORENO AVE	90049	11	126B137    57	4264005017	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM			PC Approved	12/02/2015 12:00:00 AM	ADDRESS	34.04412	-118.48534	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.57 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9313	18041-20000-08962	4733 W SUNSET BLVD	90027	13	147B197   604	5543012018	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.09833	-118.29305	PLANCHECK FOR POWER AND ENERGY. T.I. OF (E) SIMULATION LAB IN MEDICAL OFFICE BLDG. 875 QFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9314	15041-10000-14415	845 N BUNKER HILL AVE	90012	1	135A213   132	5407007010	R4-1	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Apartment			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.06449	-118.24277	Replace exisiting fire panel & installing 11-fa devices. New panel shall be compatible with all existing fa devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9315	14041-20000-17299	1031 W 34TH ST ESH	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	PIN	34.02400284	-118.2895744	PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  THREE STORY COMMERCIAL BUILDING REPLACEMENT OF LIGHTING FIXTURES. ALL CIRCUITS EXISTING. THIRD FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9316	13041-10000-12707	5900 W WILSHIRE BLVD 14TH &-15 TH FLs	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	TENANT IMPROVEMENT TO EXISTING OFFICES ON THE 14TH FLOOR AND 15TH FLOOR.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9317	17041-10000-27382	300 S CENTRAL AVE	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.04516	-118.23941	REPLACE EXISTING FIXTURES WITH LED FIXTURES T/24 ONLY. TOTAL SQUARE FT 24570.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9318	16041-10000-29403	23115 W SHERMAN PL	91307	12	183B097    55	2021014044	CR-1VL, P-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.20115	-118.63061	FULL PC FOR POWER AND ENERGY CORE SHELL FOR FUTURE MEDICAL OFFICE BUILDING. SCOPE INCLUDES A NEW 2000A 277/480V 3 PHASE, 4 WIRE SERVICE/DISTRIBUTION BOARD AND ONE NEW SUBPANEL. TOTAL AFFECTED AREA IS 18129 SQ. FT. ((ref. B# 16010-10000-03696)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9319	16041-10004-37601	4715 N HEAVEN AVE	91364	3	168B093   198	2074040002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.15661	-118.63216	11/29/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE RELOCATING THE MODULES, INVERTER ON THE SINGLE LINE DIAGRAM, AND ROOF-LAYOUT.NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-37601(((((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.099KWac / 11.00KWac.(37)MODULES-SUNPOWER SPR327NE-WHT-D(1)INVERTER-SUNNYBOY SMA SB6000TL-US-22(1)INVERTER-SUNNYBOY SMA SB5000TL-US-22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9320	15041-10000-14116	3559 N PUEBLO AVE	90032	14	144A235   378	5218008026	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Closed	03/11/2016 12:00:00 AM	ADDRESS	34.08698	-118.17462	new fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9321	19041-20000-07459	11671 W ERWIN ST	91606	2	177B169   333	2335032017	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Apartment			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.18318	-118.3868	Fire alarm system for new 4-story 10-unit apartment building.  (42) devices with FACP, RPS, and annunciator panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9322	18041-10000-19566	4701-4703 E YORK BLVD	90042	14	156A223   126	5474016011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM			Verifications in Progress	05/30/2018 12:00:00 AM	ADDRESS	34.12274	-118.2128	Power plan check for a service upgrade in a commercial building. Scope includes new service, and (19) panels.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9323	18041-10000-16323	10250 W SANTA MONICA BLVD #2330	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for first time tenant ""Volcom"" in Westfield Cetury City. Install (3) panelboards, and (1) 30 kVA transformer. Power fed from DB-ELA 44. Total area: 2,536 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9324	15041-20000-24285	10776 W WILSHIRE BLVD	90024	5	132B153   262	4325004205	[Q]R5-3-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.05985	-118.43904	PLANCHECK FOR POWER. INSTALLATION OF AN 225KVA TRANSFORMER AND 800 AMP PANEL FOR FUTURE EV CHARGERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9325	14041-10001-34351	11333 N DE FOE AVE	91331	7	210B161    45	2533008011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	34.27605	-118.41897	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 5.98 KW DC SOLAR RRAY ON A SINGLE DWELLING HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR327NE-WHT-D(1) INVERTER: POWERONE PVI-6000-OUTD-S-US-A.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9326	18041-10000-07818	1487-1489 W SUNSET BLVD C;D;E;F;G;-H;I	90026	13	139-5A209 265	5406001017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	03/27/2021 12:00:00 AM	ADDRESS	34.07579	-118.25466	PC FOR CHANGE OF USE FROM OFFICE TO RESTAURANT. SCOPE INCLUDES NEW PANELS, RECEPTICAS AND LIGHTING. PROJECT ADDRESS 1487-1489	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9327	16041-10000-43638	12460 W VICTORY BLVD	91606	2	180B165   728	2333007054	(T)(Q)C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.18646	-118.4049	PC FOR ENERGGY. REMOVE HID FIXTURES AND RPLACE WITH NEW LED FIXTURES. TOTAL (OUTDOOR) AREA 27700 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9328	12041-20000-13810	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL, [Q]R3-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00, 1204.00	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.2215	-118.42999	NOT A STATE LICENSED BUILDING, NOT CHECKED FOR OSHPD.  T.I. to north 3 building (Kaiser Permanente Medical Center) - LL Suite -  Clinic record dept.  Install subpanels, branch circuits, and new lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9329	16041-30001-01831	1999 S AVENUE OF THE STARS # 3425	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLAN CHECK ONLY.  PERMIT TO BE PULLED UNDER MASTER PERMIT NUMBER 16041-30000-01831      Changes to approved set.  Changes to lighting layout.  Existing lighting to be used in some spaces.     Title 24 plan check only.  Total area = 2,495 sq. ft.T.I. to existing commercial office highrise.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9330	19041-20001-03672	1603 S LA CIENEGA BLVD	90035	5	129B173   902	4303028031	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			Corrections Issued	05/22/2019 12:00:00 AM	ADDRESS	34.04895	-118.37642	POWER PLAN CHECK ON SINGLE LINE DIAGRAM PER INSPECTOR'S REQUESTSUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CLOUDED DELTA 1 AND 2 CHANGES ONLY. CHANGE IN FEEDER AND SERVICE CONDUCTOR SIZES. ADDITION OF A 400A DISCONNECT AND EV CHARGER TO SINGLE LINE DIAGRAM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9331	19041-20000-07784	1430 S LINCOLN BLVD	90291	11	111B145  1013	4243004034	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	33.99777	-118.46003	TI to (E) commercial office spaces.  Plan check for energy.Associated building permit issued under 17016-10000-12843.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9332	16041-10000-44012	18025 W VENTURA BLVD	91316	5	171B125   350	2162005131	(Q)C2-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.16497	-118.52509	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 28350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9333	12041-10000-09342	389 E TERMINAL WAY	90731	15	018B201   824	7455019916	C2-2	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.74208	-118.2656	INSTALLATION OF TWO NEW SHORE-TO-SHIP POWER PLUGS WITH TWO 6.6 KV SWITCHGEARSAT BERTH 228	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9334	07041-10002-17643	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.03393	-118.22985	UPGRADING SEVICE TO 600A ; NO OTHER CHANGESInterior remodel to existing 11 unit artist lofts building .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9335	10041-20001-13274	14539 W BLYTHE ST	91402	6	189B149   311	2210019005	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.21533	-118.44994	Changes to approved set of plans; previous plans were for PV only. New 400A service, 600A panel for PV, new inverters for 3 phase configuration. Modules are the same as those used previously in 10041-20000-13274.this project is a FIT, pv connection straight to DWP. 95KW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9336	19041-10002-01226	459 S HARTFORD AVE	90017	1	132A207    95	5153024009	CW    R5(CW)-U/6	Central	Westlake	Westlake North		2091.03	Electrical	Electrical	Apartment			09/18/2019 12:00:00 AM			PC Approved	09/18/2019 12:00:00 AM	ADDRESS	34.05708	-118.26381	PLAN CHECK FOR DELTA #2 CHANGES ONLY (ALL CHANGES HAVE BEEN CLOUDED) - CHANGES INCLUDE REDUCTION OF LIGHTING, PHOTOMETRICS, EQUIPMENT AND ALTERATIONS TO TITLE 24 TO REFLECT CHANGES Full plan check for a  7 story , 101 unit affordable housing, over 1 level parking space.  Scope includes a 2500-Amp, 120/208V, 3ph, 4W, 68KAIC per LADWP WMIS service with (8) typical units.B# 18010-10000-03723	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9337	19041-20000-12263	3533 W 59TH ST	90043	8	105B185    26	4004006018	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	33.9873	-118.33421	Plan check for PV roof mounted system, PV system size: 2.9KW DC, 3.0KW AC with 10 PV Modules and 1 inverter(3.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9338	17041-10000-05479	19831 W NORDHOFF PL	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.23691	-118.56541	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR) 61950 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9339	15041-20000-30493	14236 W RAVEN ST	91342	7	222B153   591	2508013008	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.30323	-118.44301	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (21) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9340	10041-20000-03107	15505 W ROSCOE BLVD	91343	6	192B145   365	2654028027	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills			1174.08	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM			PC Approved	02/23/2010 12:00:00 AM	ADDRESS	34.22156	-118.47097	Galpin Ford Service Drive remodelT-24 exist. permit 10041-90000-00411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9341	18041-10000-31411	4219 N LANKERSHIM BLVD	91602	2	165B177   893	2423026001	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.14633	-118.36362	CONVERT (E) OFFICE SPACE INTO KITCHEN FOR (E) ADULT DAY CARE CENTER.NO NEW LOAD ADDED. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-26427	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9342	18041-10000-16349	900 S KENMORE AVE	90006	10	132B197   845	5094023038	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			05/03/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	08/11/2021 12:00:00 AM	ADDRESS	34.05574	-118.29639	PC for power and energy for a NEW 29 UNIT MULTI APARTMENT  (7 STORY ABOVE GRADE) WITH  2 LEVEL  PARKING GARAGE ( ONE LEVEL ON GRADE AND ONE LEVEL BELOW GRADE).Service rated at 1600A 120/240V 3ph. Total affected area 33365 sq.ftB#15010-10000-04658	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9343	19041-10000-34193	380 WORLD WAY SPACE T04	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	TENANT IMPROVEMENT  - COVERT A PORTION OF THE   EXISTING FOOD & BEVERAGE CONCESSION SPACE  TO NEW BRANDING ( Hung's Street Eats). Installing new lights. T-24 only. Total affected area: 241 Sqr Ft. Bulding Permit: 19016-10000-18614	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9344	18041-10000-20390	3415 W BELLEVUE AVE	90026	13	141A201   259	5401008014	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1959.03	Electrical	Electrical	Apartment			06/01/2018 12:00:00 AM			PC Info Complete	06/14/2019 12:00:00 AM	ADDRESS	34.07952	-118.28143	FULL PC FOR POWER AND ENERGY FOR A NEW 14 UNIT APARTMENT OVER A PARKING GARAGE. SCOPE INCLUDES A NEW 1200A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARDS, NEW PANELBOARDS, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 15257 SQ. FT. B#18010-10000-02619	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9345	17041-10000-43535	816 W GEORGIA DR	90710	15	036B197  1142	7413024158	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	33.79312	-118.28961	Plan check for PV roof mounted system. System size: 3.0kW with 8 modules and 1 inverter(3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9346	19041-30000-21638	800 W WILSHIRE BLVD 5th Floor	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.0493	-118.25841	Plan check for Title 24 only. Project site is the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,077 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9347	13041-10000-27863	3767 S 2ND AVE	90018	10	117B189   251	5042009029	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.01976	-118.31907	PV1. INSTALL ROOF MOUNTED PHOTOVOLTAIC SYSTEM. INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 7.5 kW. TRANSFORMERLESS USING SOLAREDGE SE6000, POWER OPTIMIZER , AND (30) TRINA SOLAR # TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9348	16041-10000-03749	21 E THORNTON AVE 1-35	90291	11	109-5A143 411	4286023028	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Expired	03/02/2018 12:00:00 AM	ADDRESS	33.99248	-118.47759	Plan check for a new fire alarm system located in a 4-story 35-unit apartment building. Scope includes ( 1) fire alarm panel, (1) communication panel, (1) control panel, and (90) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9349	16041-10000-06477	5122 W ORANGE PL	90008	10	117B177   456	5029002025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.01492	-118.35713	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 1.935KWac.(9)MODULES-HYUNDAI HIS-S260RG(9)MICROINVERTERS-ENPHASE M215-602LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9350	14041-20000-31543	12120 W TERRA BELLA ST unit 40	91331	7	210B165   287	2532017034	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	Apartment			11/13/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.27367	-118.39699	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER NON STANDARD PLAN WITH POWER OPTOMIZERS. SYSTEM SIZE: 3.8 KW AC.[[[ 2 DIFFERENT SIZE OF MODULES]]] (17)  CANADIAN SOLAR C86P-235  AND C86P-250(1) SOLARD EDGE SE3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9351	18041-20000-38707	14613 W DEL PLAYA ST HSE	91402	6	201B149   361	2650019024	(Q)RD2-1, (Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.24792	-118.45082	Plan check for Title 24 only for outdoor commom area drive way, small parking lot, and hardscape area. Total area: 15816 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9352	16041-20000-20538	1778 W 36TH PL	90018	8	120B193  1463	5041023005	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.02178	-118.31126	Plan check for PV roof mounted system. system size: 3.8kW with 15 modules and 1 inverter (3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9353	17041-10000-06880	8960 W PICO BLVD	90035	5	132B169   866	4305007031	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.05509	-118.38751	PC for outdoor title 24 only. Removing HID fixutres with new LED fixutres. Area: 4800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9354	19041-30000-24326	1446 N DETROIT ST 1-44	90046	4	147B181   685	5548017050	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.09751	-118.34507	PC FOR FA SYSTEM. 1 FACP AND 180 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9355	17041-30000-38706	523 W 6TH ST #502	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	Plan check for Title 24 only. Project stie is an existing tenant space in a high-rise building. Project scope is a tenant improvement. Total lighting area = 4,630 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9356	14041-10000-09262	3225 W GLENHURST AVE	90039	13	153B209  1157	5437011004	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.11198	-118.25753	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM USING STANDARD PLAN. TOTAL SYSTEM SIZE 6.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9357	16041-20000-35328	17180 W BALLINGER ST	91325	12	198B133    25	2692018011	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.24346	-118.5084	Plan check for installation of pv system on SFD, roof-mounted. Interconnect with a 225A MSP. 12kW ungrounded system (6+6). (61) 255W pv modules. Each module has a 300W power optimizer.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9358	10041-10000-24707	517 W 7TH ST	90014	9	129A209   142	5144004035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.04706	-118.25596	refurbished 4-stories building with  floors 1 thru 3 to be commercial tenants and the 4th fl to be a residence.plan chk is for  shell and core and the 4th fl residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9359	10041-10000-19148	924 S WESTWOOD BLVD # 920	90024	5	135B153   539	4363019902	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.06308	-118.44513	REMODEL OFFICES/SALES AREASPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9360	13041-10000-19704	2000 S AVENUE OF THE STARS 12THFLOOR	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	ADDRESS	34.05868	-118.41546	TITLE 24 PLAN CHECK ONLY. EMERGENCY LIGHTING. 7348 SQFT. HIGH RISE TENANT IMPROVE MENT ON THE 12TH FLOOR. THE CORRIDORS ARE UNDER A DIFFERENT PERMIT #	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9361	13041-20002-33562	24642 W STONEGATE DR	91304	12	186B089    55	2017029009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.20975	-118.6573	New 11.25 kw rooftop PV modules for an existing sfr. Changes to approved set of plans. change in roof layout and system size. system is now 8.6kw ac. pc only. no permit to be issued from this application$0 plan check fee due to fee cap from sentae bill 1222 from 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9362	10041-10000-07082	820 N WESTERN AVE 105	90029	13	141B193   338	5535018037	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	05/10/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.08511	-118.30896	Ti IN AN EXISTING COIN LAUNDRY. REFEED EXISTING PANELS AND INSTALL A NEW PANEL. APPLICANT IS REQUESTING ELECTRICAL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9363	17041-10000-45530	14234 W GREENLEAF ST	91423	4	165B153   736	2266010006	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.14727	-118.44318	*zero dollar permit fee due per Senate Bill 1222*NEW 17KW SYSTEM CONSISTING OF 50 MODULES (WITH 50 P370 POWER OPTIMIZERS), AND 3 CENTRAL INVERTERS ((2)SE6000H-US AND (1)SE5000H-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9364	15041-10000-13716	17200 W VENTURA BLVD #229A	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.16035	-118.50769	ADDITION OF LD LUMINAIRES IN BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9365	19041-10000-53446	1310 W 6TH ST	90017	1	132A207   225	5143016010	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.05545	-118.26599	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9366	17041-20001-04649	11249 W CALIFA ST	91601	2	177B173  1395	2337013011	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Apartment			02/13/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.1777	-118.37637	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building (unit #B).3kW ungrounded system. (6) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9367	19041-20000-03650	18765 W FAIRFIELD ROAD	91326	12	207B121   627	2728029044	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.26205	-118.54171	Install 27 kWh energy storage system, load center, and critical load panel.  (E) PV system on site.Main service disconnect derated to 350A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9368	13041-20000-06147	23843 W WELBY WAY	91307	3	180B089   109	2034001033	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.19274	-118.64616	"rooftop pv system for an existing single family residence.  System is ungrounded and has additional DC power optimizers.  Misc. permit is for ""Power Optimizers""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9369	11041-10000-09951	2201 S LINCOLN BLVD	90291	11	108B149   307	4241034001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Public Safety Only			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	33.99481	-118.45469	0NEW FIRE WARNING SYSTEM  IN  SINGLE STORE SCHOOL ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9370	15041-20000-18153	16331 W TUDOR DR	91436	5	162B137   384	2286004051	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.1391	-118.48777	Plan check for PV roof mounted system. System size: 7.6kW with 28 modules and 2 inverters(3.8kW) trasformerless.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9371	13041-10005-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.10155	-118.31097	05/03/2017. changes to the approved set of plan including changing the 3 grounding feeder size. plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9372	16041-10000-42987	22536 W SOUTH SUMMIT RIDGE CIR	91311	12	198B097    60	2727022081	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM			Corrections Issued	12/08/2016 12:00:00 AM	ADDRESS	34.23937	-118.61823	PC FOR GROUND MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE 12.6KW AC USING 2 CENTRAL INVERTER SYSTEMS WITH POWER OPTIMIZERS. TOTAL OF 54 MODULES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9373	15041-20001-09002	17616 W BLYTHE ST	91325	12	189B129   602	2201032003	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.21483	-118.51723	Supplemental application for expedite fees.Installation of new roof mounted solar PV arra.  Total system size = 6.8 kWac.  Two inverter system with 4 strings and 33 total modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9374	13041-20000-33854	9261 N RUBIO AVE	91343	12	198B137   546	2687026020	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.23916	-118.49547	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC. 36 MODULES AND 2 INVERTERS. LOW PERMIT FEES DUE TO 2012 SENATE BILL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9375	14041-20001-20740	11201 N CHALON ROAD Guest-House	90049	5	141B145   149	4369009007	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.08239	-118.46048	[[ 6/22/17 CHANGES TO APPROVED SET. PLANCHECK ONLY REFLECTS CHANGES TO GUEST HOUSE, GATEHOUSE, POOLHOUSE AND MAIN HOUSE. DELTA 5 CHANGES ARE CLOUDED. CHANGES INCLUDING INDICATION OF FULLY RATED BREAKER TYPES ON SLD, RELOCATION OF POOLHOUSE PANEL, ADDITION OF FUTURE GUARD HOUSE PANEL AND FUTURE KITCHEN EQUIPMENT SKID, ADDITION OF LOW VOLTAGE LIGHTING PANELS, AND UPGRADING GUEST HOUSE TRANSFORMER TO 500KVA]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9376	14041-20000-30266	2740 E OLYMPIC BLVD	90023	14	120A221    67	5170027006	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.02352	-118.21855	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO CARWASH. <400 AMPS. 2008 T24 COMPLIANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9377	18041-10000-16614	7540 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.94052	-118.42863	PC for power and energy for LAX delta airlines high bay hangar with one story of office space. new lighting panels and circuits. Total area is 124451 sqft. B# 18010-10000-00614.(Title 24 related information only)power will be submitted under different permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9378	15041-10000-34359	415 W ELBERON AVE	90731	15	021B197   787	7448024003	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	33.75057	-118.28803	PV 1 installation to a single family home Roof mounted solar system. (1) Inverter: 3kw, (8) solar modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9379	18041-10000-18099	2205 S STONER AVE	90064	11	123B149   476	4260011002	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Info Complete	05/15/2018 12:00:00 AM	ADDRESS	34.03331	-118.44863	TI IN AN EXISTING 2 STORY OFFICE BUILDING.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9380	14041-20002-18659	10531 N OKLAHOMA AVE	91311	12	207B109   550	2706012008	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM			PC Approved	08/12/2014 12:00:00 AM	ADDRESS	34.26194	-118.58658	PV1 12.24KW roof-mounted system with (48) Trina solar TSM-255P modules and Solaredge p300 Powerbox Optimizers, and (2) Solaredge SE5000 inverters connecting through a load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9381	15041-10000-35452	10881 W WILLOW CREST PL	91604	2	162B173   979	2380007021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.13677	-118.36867	PV1, INSTALL 13.40 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (41) MODULES: SUNPOWER SPR-327-NE-WHT-D(3) INVERTER: POWER-ONE PVI-3.8 & 5000-OUTD-US-A 240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9382	16041-20000-32039	5510 S LINCOLN BLVD 4th floor	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	33.97299	-118.43051	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OFFICE. 219 SQFT. 4TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9383	12041-20000-27138	7044 N VASSAR AVE	91303	3	183B105   488	2138003004	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			11/09/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.19872	-118.60422	Plan check for power and energy. new 800A service. 10 unit, 3 story apartment with 12 parking spaces in an underground parking garage. 8500sqft parking garage. TO COMPLY W/ DEPT. ORDER DATED 10/4/11.  PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9384	15041-20000-03026	12481 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	33.9791	-118.41047	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9385	15041-10001-26927	12625 N GLENOAKS BLVD	91342	7	219B153   136	2508027012	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29948	-118.43958	REVISION TO THE APPROVED SET OF PLAN, REVISION INCLUDES: INSTALLATION OF 75 KVA TRANSFORMER AND BALARD FOR SWITCHGEAR PROTECTION(12/1/2016).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9386	17041-10000-05475	2489 W WASHINGTON BLVD	90018	10	126B189   886	5073024027	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			Verifications in Progress	11/03/2017 12:00:00 AM	ADDRESS	34.04008	-118.31742	PC FOR POWER. SERVICE UPGRADE TO 600A , AND ADDITION OF 8 NEW PANELS. MIXED USED APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9387	17041-10000-12918	21857 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Expired	01/19/2018 12:00:00 AM	ADDRESS	34.1686	-118.60359	PC FOR POWER AND ENERGY. TI FOR PROPOSED RESTAURANT. EXISTING SERVICE AND DISTRIBUTION BOARD. NEW 600A  PANEL AND 3 NEW 200A PANELS. Total area 4000 sq ft. B # 17016-10000-10036	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9388	18041-10000-01499	7240 N HAYVENHURST PL	91406	6	186B137   239	2205010905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20231	-118.49217	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 213,100 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9389	10041-20000-19356	990 W 190TH ST #555	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	08/24/2011 12:00:00 AM	ADDRESS	33.85813	-118.29505	energy plan check # 555	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9390	13041-10000-30389	19320 W NORDHOFF ST	91324	12	198B117   230	2783028057	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	12/26/2013 12:00:00 AM	ADDRESS	34.23529	-118.55444	New fire alarm plan for Pets Store, existing building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9391	14041-20001-00745	8853 N MOORCROFT AVE	91304	12	195B101   132	2004024020	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/18/2014 12:00:00 AM	ADDRESS	34.23165	-118.61103	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 11.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9392	12041-20000-12402	145 S FAIRFAX AVE 2ND,3RD,4T-H	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	PIN	34.07292853	-118.36175524	ENERGY PLAN CHECK 2ND,3RD,4TH FLOOR COORIDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9393	18041-10001-42741	3628 N VERDUGO VISTA TER	90065	1	154-5A219  56	5472013002	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.11928	-118.22334	SUPPLEMENTAL FOR FEE EXPEDITEPLAN CHECK FOR ROOF MOUNTED PV SYSTEM AND ENERGY STORAGE SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600-USS), 23 MODULES/P30 OPTIMIZERS, AND LE CHEM BATTERY(9.8KVA)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9394	16041-20000-22621	12400 W SANTA MONICA BLVD	90025	11	126B145   919	4267031003	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.03888	-118.46666	Installation of New fire alarm system. 1 FACP AND 60 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9395	14041-10000-08489	1999 S AVENUE OF THE STARS SUITE 2500	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	34.05886	-118.41642	T24 FOR EXISTING OFFICE SPACE. TENANT ON SUITE 2500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9396	14041-10000-27164	3880 E SAN RAFAEL AVE	90065	1	148-5A221  25	5465001004	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.10212	-118.21724	Installation of new fire alarm system. 1 fire alarm panel and 3 remote power supplies and 194 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9397	16041-10000-05907	3717 W JEFFERSON BLVD	90016	10	120B185   813	5050030061	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.02571	-118.33695	CHANGE OF USE FROM  SLAUGHTER HOUSE TO PRECISION MACHINE SHOP, ARTIST STUDIO. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4086.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9398	19041-10000-53523	16056 W SHERMAN WAY	91406	6	183B141   127	2224004001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	01/20/2021 12:00:00 AM		Permit Finaled	03/31/2021 12:00:00 AM	ADDRESS	34.20094	-118.48326	PLAN CHECK FOR POWER AND LIGHTHING FOR A TI. SCOPE OF WORK INCLUDES A NEW  600A 120/208V DISTRIBUTION PANEL, (4) PANELBOARDS, EQUIPMENT  AND CIRCUITS. TOTAL  AFFECTED AREA IS 3600 SQUARE FEET.  ***BUILDING NUMBER IS: 19016-20000-41053	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9399	19041-10000-31829	319 E HARRY BRIDGES BLVD	90744	15	027B209   188	7418029016	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	33.77163	-118.25839	Remove HID fixtures and replace with new LED fixtures (Indoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9400	12041-10000-17818	635 S HARVARD BLVD 126-127	90010	10	135B193  1008	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	PIN	34.06226207	-118.30448145	Permit is for 20 lights, 2 receptacles, 2 occupancy sensors and 6 switches. Classrooms 126 1nd 127.Plan check for energy and emergency lighting. Classrooms inside a temple. Occupancy load is around 60. 1197 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9401	17041-10000-29917	16946 W GRESHAM ST	91343	12	195B133   366	2688041026	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	03/15/2019 12:00:00 AM	ADDRESS	34.23015	-118.50165	Install a new PV system on a SFD and upgrade service to 200A.36 PV panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9402	16041-10006-42610	695 S SANTA FE AVE	90021	14	124-5A2171363	5164019026	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	09/04/2020 12:00:00 AM	ADDRESS	34.03508	-118.23039	CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON CLOUDED AREAS DELTA X. CHANGES INCLUDE INCLUDE ADDING SEPARATE CIRCUITS FOR LAUNDRY EQUIPMENT, REVISING UNIT FLOOR PLANS, REVISING LOAD CALCS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9403	15041-10000-31524	19821 W NORDHOFF PL STE 114	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.23686	-118.56502	REMOVE EXISTING HID LIGHTING AND REPLACE WITH NEW LED LIGHT FIXTURES. PLAN CHECK FOE ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9404	19041-20001-18848	6436-6440 N PLATT AVE	91307	12	180B093   512	2036024053	(Q)C1-1VL, (Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL, C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.18785	-118.64248	CHANGES TO APPROVED SET DELTA 3 ONLY. CHANGES INCLUDE RELOCATION OF PANELS, LIGHTING FIXTURES AND EMERGENCY LIGHTING.<<<Change of use from retail to medical office.  Plan check for power and energy.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9405	11041-20000-00390	18870 W PASADERO DR	91356	3	165B121   349	2177025018	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	04/25/2011 12:00:00 AM	ADDRESS	34.1485	-118.54517	Plan check new roof mounted 14.1KW photovoltaic system for single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9406	12041-10000-04807	332 S HIGHLAND AVE	90020	4	135B185   176	5507003006	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Expired	05/28/2014 12:00:00 AM	PIN	34.06789293	-118.33812022	Plan check new roof mounted 16KW photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9407	19041-10000-35320	12103 W VENTURA BLVD	91604	2	162B165  1112	2367016013	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Approved	09/06/2019 12:00:00 AM	ADDRESS	34.14369	-118.39571	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT OF EXISTING RESTAURANT. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFCETED AREA IS 2744 SQ.FTB# 19016-10000-28039	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9408	17041-20000-18036	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Issued	08/30/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Install new light fixtures under solar canopy on rooftop of parking garage.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9409	16041-10000-03874	940 S WESTERN AVE	90006	10	132B193  1115	5080008018	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.05431	-118.30888	New Fire alarm system with sprinkler monitoring system on (E) 6-story, mixed use 78 unit apartment, ground level retail, and 3-level subterrean parking garage.(1) Fire alarm panel    (1) comm. panel   (362) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9410	11041-10000-13729	1545 W WILSHIRE BLVD 8th FL	90017	1	132A205   208	5142027025	CW	Central	Westlake			2091.02	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Issued	08/16/2011 12:00:00 AM	ADDRESS	34.05543	-118.26977	new panelboard and circuits in renovating offices on the 8th flplan check is for title24 and 1 ea emergency ckt ; permit fee is in Inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9411	15041-10000-05572	1129 S BOYLE AVE	90023	14	123A221   272	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.03059	-118.2205	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3905SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9412	18041-10000-16440	2624 S LETA ST	90011	9	117A213   298	5118015025	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.014	-118.24552	REPLACE INDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9413	12041-10001-17515	10700 W SANTA MONICA BLVD STE 3	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM			PC Approved	08/02/2012 12:00:00 AM	ADDRESS	34.05167	-118.432	Provide additional electrical in suite 140. Provide and install 200A 277480 panel, 30kva xfmr, 100A 120/208 panel. Connection to RTU. Electrical at restrooms.  Building is in a Methane Zone, All of the conduits or conductors are above the membrane for this scope of work.  PLAN CHECK ONLY.  No lighting.  New Tenant may require a full plan review.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9414	17041-10000-24630	8471 W BEVERLY BLVD Suite #101	90048	5	138B173   428	5514012025	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.07621	-118.37572	PC for T24 for retail TI. PC for new lighting. Total area is 3003 sqft. Load under 400A. Installing new circuits and equipment. building #17016-10000-19969 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9415	19041-10000-37201	5006 N MEDINA ROAD	91364	3	168B105   194	2168009022	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.15929	-118.60021	$0 Fee due to AB1414. pc for pv-1 system. system size is 16.500kw. (50) panasonic panels with microinverter. 2-(200) combiner load centers and 1 production meter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9416	19041-30000-09743	14715 W BLYTHE ST	91402	6	189B149   364	2210020018	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Apartment			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Issued	03/19/2019 12:00:00 AM	ADDRESS	34.21531	-118.45356	Plan check for a fire alarm system for a 4-story, 26-unit fire alarm system. System consists of (1) FACP and (86) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9417	19041-20000-52431	6801 W SANTA MONICA BLVD	90038	4	144B185   725	5532019016	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	11/05/2020 12:00:00 AM		Permit Finaled	09/16/2021 12:00:00 AM	ADDRESS	34.09088	-118.33885	PV3.  Install 129.56 kW DC roof mounted PV system.  (328) modules with 100 kW inverter.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9418	16041-20001-06630	18722 W STRATHERN ST	91335	3	189B121   256	2103012013	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.21552	-118.54136	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.4 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9419	17041-10000-16244	1320 E 7TH ST	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	05/16/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	PC for enrgy only. TI on second floor of an existing two story building. New lighting and power in office building. Area: 11,069 Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9420	16041-10000-19753	755 S SPRING ST	90014	14	127-5A211 157	5144015018	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Closed	08/30/2018 12:00:00 AM	ADDRESS	34.04336	-118.25369	PC FOR POWER ONLY. SCOPE INCLUDES TEMPORARY POWER FOR A CONSTRUCTION SITE. TEMPORARY POWER IS FOR A NEW 24-STORY MIXED USE BUILDING. ADDING A 625KVA 480V , 3PH, 3WIRE GENERATOR, A NEW 800A 480V, 3PH, 3WIRE MAIN DISTRIBUTION BOARD, NEW SUBPANELS,  AND LOAD EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9421	13041-20000-09331	18810 W VANOWEN ST	91335	3	180B121    39	2126035028	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20, 1325.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.1937	-118.54306	ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9422	13041-20000-14817	7331 N LAUREL CANYON BLVD	91605	2	186B165   260	2307022010	(T)(Q)M2-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	ADDRESS	34.20408	-118.39671	NEW LIGHITNG IN AUTO AUCTION TENT. CONSIDERED TO BE OUTDOOR LIGHTING BER ENERGY COMMISSION. TOTAL AREA 4710 SQFT.  PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9423	10041-20000-10850	601 W 5TH ST	90071	9	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	06/09/2010 12:00:00 AM		Permit Finaled	07/14/2010 12:00:00 AM	ADDRESS	34.05049	-118.25386	Replace fire damage electrical equipment  ( no new load is being added ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9424	17041-20002-04249	1697 S PACIFIC AVE ROOFTOP	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	33.98722	-118.47211	05/17/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the lighting and power floor plans. All changes have been reflected onto the Title 24 forms.11/6/2017 Changes to an approved set of plans.  changes noted delta 1.  changes include lighting fixture types and revised energy calculations.  this is plan check only.  *****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NEW ROOFTOP KITCHEN. PHASE 1. NOT A HIGHRISE PER APPLICANT. NEWLY CONNECTED LOAD < 400 AMPS.  332 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9425	16041-20000-18000	22741 W VICTORY BLVD	91307	12	180B097   546	2038038021	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.18663	-118.6225	PLANCHECK FOR TITLE 24 OUTDOOR LIGHTING ONLY.  FALLBROOK SHOPPING CENTER. 5850 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9426	15041-10000-25468	700 S FLOWER ST 17th Flr	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	Energy plan check for an office T.I located at the 17th floor of a high rise building ; Scope includes new light, equipment and receptacles. Total area is 22,668-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9427	16041-10000-42768	17314 W TRAMONTO DR 1-2-Bldg 8	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	08/19/2021 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building  2 story 2 units (Type D) .  With 1 service 4,000A feeding all 9 buildings.Note: This is 9 buildings submit  in 1 plan. 8 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9428	17041-20000-30507	21042 W VINTAGE ST	91311	12	201B105    28	2747003020	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.25121	-118.59225	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (36) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9429	17041-10000-18539	2049 S CENTURY PARK EAST 3RD FL .LB	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR TITLE 24 ENERGY ONLY FOR 3RD FLOOR ELEVATOR LOBBY. TOTAL AFFECTED AREA 325 SQ.FTINSTALLING NEW LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9430	14041-20000-18026	4857 N TYRONE AVE	91423	4	168B153   193	2248003009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.15922	-118.44446	7.95KW PV1 roof-mounted with (30) Enphase M215 microinverters and Sunedison 265W modules connecting through a 125amp subpanel load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9431	14041-20000-19406	847 N MICHELTORENA ST	90026	13	142-5A203 362	5427031015	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.08355	-118.27849	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.36KW INTERCONNECTED WITH MAIN SERVICE PANEL.(14) ENPHASE M250 MICROINVERTERS(14) SOLARWORLD SW280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9432	12041-10000-10716	18433 W ROSCOE BLVD	91325	12	192B125   578	2786022035	QC1-1VL, QP-1VL	North Valley	Northridge	Northridge South		1154.02	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.22091	-118.53469	Licensed Medical Facility.  Suite 214.  New sub panel with lighting and receptacles.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9433	14041-20000-26938	12830 N WHEELER AVE	91342	7	222B161   369	2525003032	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.30331	-118.41616	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9434	12041-10000-21097	21031 W WARNER CENTER LANE	91367	3	174B105    24	2149017007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM			PC Approved	09/11/2012 12:00:00 AM	ADDRESS	34.17501	-118.59119	Remove & Relocate lighting in a commercial BLDG. EPC is for T24. (suite#100)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9435	14041-20000-13634	10309 N LARAMIE AVE	91311	12	204B113   151	2707023011	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Expired	07/15/2016 12:00:00 AM	ADDRESS	34.25783	-118.57297	11.25 Kw PV1 roof-mounted system with (2) transformerless Power-One Aurora PV1-4.2-OUTD-S-US inverters and (45) Canadian Solar #CS6P-250PX modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9436	15041-10000-31638	2910 N HUMBOLDT ST	90031	1	141A221   153	5205017015	MR1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.08085	-118.2165	T-24. Replacing existing lights with new LED light fixtures. Scope of work is being done in a commmercial building. PC for energy only. Sq Ft = 10,191	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9437	15041-10001-26532	633 W 5TH ST LEVEL 2	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM			PC Approved	04/07/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	RECHECK T24 ONLY. REMOVING 15 OUTDOOR LIGHTING FIXTURES FROM THE SCOPE OF THE WORK : 85 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9438	19041-30000-22290	11570 W VENTURA BLVD	91604	2	162B169   577	2369035045	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	07/18/2022 12:00:00 AM	ADDRESS	34.13989	-118.38413	$0 permit fee due to SB1222 and AB1414Plan check for a PV2 roof-mounted PV system. System size is 36.3 kWdc/32.527 kWac-CEC and consists of (1) 30 kWac rated inverter, (108) modules with (54) optimizers, and (1) 45kva transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9439	14041-20000-26292	14801 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.17768	-118.45513	Plan check for energy only. TI to existing office building, new receptacles and lighting (incl. emergency). 9,186sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9440	11041-10000-16917	2211 1/2 W WASHINGTON BLVD	90019	10	126B193   882	5073013023	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	PIN	34.04026639	-118.3095456	T.I.  Existing commercial space that is being divided in to two separate spaces.  Plan check is for energy only for 2211 1/2 Washington Bl.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9441	13041-10000-24787	2016 E BAY ST	90021	14	123A217   199	5166011021	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.03132	-118.2316	TITLE 24 PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALLING NEW FLUORESCENT FIXTURES. EMERGENCY LIGHTING EXISTING TO REMAIN. 7600 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9442	13041-10001-30447	578 S LORNA LANE	90049	11	132B145   226	4401011010	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.05701	-118.46992	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY. MICROINVERTER NON STANDARD PLAN. SYSTEM SIZE: 6KW DC.  1 STORY HOUSE.(24) 250 W PV MODULES(24) 215 W ENPHASE MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9443	19041-10001-52926			11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM			PC Approved	01/29/2020 12:00:00 AM	PIN	34.08562961	-118.48276081	[EPLAN] SUPPLEMENTAL FOR EXPEDITED FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9444	13041-10000-11724	2121 E 7TH PL	90021	14	124-5A217 295	5166002022	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.03368	-118.22913	New outdoor lighting for a restaurant patio area.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9445	18041-10000-21087	5335 W ADAMS BLVD	90016	10	123B177   923	5043002010	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	12/11/2020 12:00:00 AM	ADDRESS	34.03268	-118.3593	PLANCHECK FOR POWER AND ENERGY. NEW 3 STORY MIXED USE BUILDING WITH 60 UNIT APT.BUILDING PERMIT #  17010-10000-01522	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9446	19041-10000-47345	4204 S EAST BLVD	90066	11	111B157   473	4233007027	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Issued	12/02/2019 12:00:00 AM	ADDRESS	34.00077	-118.42008	[EPLAN] INSTALL 2 NEW TELSA POWERWALL'S, CONNECTED TO AN EXISTING 400A MAIN SERVICE PANEL. EXISTING PV1 SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9447	19041-20000-12037	15528-15532 W RAYEN ST 1-18	91343	6	195B145   262	2654014031	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Apartment			04/03/2019 12:00:00 AM	05/14/2020 12:00:00 AM		Permit Finaled	01/10/2022 12:00:00 AM	ADDRESS	34.23172	-118.47085	800A 240/120V 3ph-4w service.  Plan check for power and energy. Building permit under 17010-20000-04784.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9448	14041-20000-24398	5445 W HOLLYWOOD BLVD	90027	13	148-5A193 342	5544007***	C4-1VL, R3-1, [Q]C4-2D	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.10195	-118.3085	Change of use from Cleaners to Restaurant.  PC FOR ENERGY ONLY. T24. NEW LIGHTING. PER BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 ENERGY EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9449	14041-10000-31130	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	33.97954	-118.41361	Energy plan check for a commercial building; work including indoor and exterior lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9450	11041-10000-02769	15250 W VENTURA BLVD	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			Corrections Issued	02/11/2011 12:00:00 AM	ADDRESS	34.15351	-118.46549	Ti in an existing commercial building. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9451	19041-20000-27694	16875 W SEVERO PL	91436	5	159B133   135	2287006015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM			Reviewed by Supervisor	08/15/2019 12:00:00 AM	ADDRESS	34.13279	-118.50152	service upgrade to an existing sfd 600 amp service.  plan check for power only.this is plan check only.electrical permit under comb, building application number 17010-20000-01023	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9452	17041-30000-18958	6600 N TOPANGA CANYON BLVD #2094	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only in existing space. retail T.I. Total area: 1089 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9453	12041-10000-13477	1360 S WESTWOOD BLVD #B	90024	5	132B153   766	4325016015	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/11/2012 12:00:00 AM			PC Approved	06/29/2012 12:00:00 AM	ADDRESS	34.05594	-118.44192	New addition to an existing Ross Retail space for a pharmacy.  Load is less than 100A, plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9454	14041-20001-09708	10017 N WISH AVE	91325	12	204B133   578	2694007026	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM			PC Approved	05/22/2014 12:00:00 AM	ADDRESS	34.25289	-118.50807	pc for pv1 single family dwelling. total system size 6kw ac using transformerless inverter. nonstandard plan. 3 strings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9455	13041-20000-16240	941 N ONEONTA DR PV-1	90065	14	153A221   197	5475016040	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.11388	-118.21571	PV-1. Transformerless inverter. ONe 3kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9456	13041-10000-03928	1751 S WESTWOOD BLVD	90024	5	129B153   370	4324028047	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.05089	-118.43821	PLAN CHECK FOR FIRE ALARM. SPRINKLER MONITORING SYSTEM. NEW FIREA ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9457	14041-20000-10534	6451 N NEDDY AVE	91307	12	180B089   812	2033002004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.18726	-118.65341	PV1.  Install 4 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9458	18041-30000-22187	801 S BERENDO ST	90005	10	132B197   464	5094014001	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Apartment			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	03/19/2021 12:00:00 AM	ADDRESS	34.05753	-118.29435	Fire alarm plan check for a fire alarm system in a 7-story 98-unit apartment building. Scope includes (1) fire alarm panel, (4) power supplies, and (287) fire alarm devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9459	19041-20000-07804	21031 W VENTURA BLVD #900	91364	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16693	-118.5916	Tenant improvement to (E) highrise commercial office space.  Plan check for energy.Building permit under 19016-40000-04794.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9460	14041-20000-10665	6453 N VAN NUYS BLVD	91411	6	180B149   701	2236016005	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	PIN	34.18780077	-118.44914857	TI for (E) retail tenant space, remodel for conversion to barber shop/barber school.  Title 24 plan check for changes to partitions and lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9461	17041-10000-43571	1523 W GRIFFITH PARK BLVD	90026	13	144A203    19	5429022004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.09067	-118.27718	T-24, PC FOR ENERGY ONLY. TENANT IMPROVMENT TO AN (E) COFFEE SHOP AND REMODEL BATHROOM. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 100 SQ. FT. B#17016-20000-26904	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9462	13041-10000-35931	1031 S MAPLE AVE	90015	14	126A209   269	5145020048	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.03773	-118.25495	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 1832 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9463	11041-20000-20594	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM			PC Approved	09/27/2011 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I.  Bank of the West on the first floor of the building.  Remodeling the light fixtures in the conference room.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9464	12041-10000-23247	10757 W ASHBY AVE	90064	5	126B157  1287	4255023011	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.03768	-118.42394	Roof mounted transformerless P.V. system (5.28KWdc).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9465	14041-20001-03546	3512 W GARDEN AVE	90039	13	154-5A207 347	5437007006	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.11682	-118.26057	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9466	19041-10000-34990	7627 N VAN NUYS BLVD	91405	6	186B149   109	2210031001	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM			Corrections Issued	09/07/2019 12:00:00 AM	ADDRESS	34.20919	-118.44903	Full plan check for power and energy, scope of work is replacement of fire damage equpment in a hazardous area (auto repair shop). Scope of work includes using exisiting panels, only adding new circuits and updating the lighting to code. Total affected area is 3146 sqft.B#19016-10000-21171	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9467	12041-10000-10255	5313 N CREBS AVE	91356	3	171B121   208	2161004036	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.16706	-118.54479	PLAN CHECK NEW 7.84KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9468	14041-20000-16733	15260 W VENTURA BLVD SUITE 1440	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.15356	-118.4658	PC FOR TITLE 24 ENERGY, FLOOR #1440.  NEW LIGHTING FIXTURES ON EXISTING CIRCUITS.  NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9469	16041-20000-27059	12676 W SEACOAST PL	90094	11	102B161  1279	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.97612	-118.41369	PV1.  Install 1.5 kW roof mounted PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9470	19041-10000-27810	20427 W VIA MEDICI	91326	12	219B109   287	2701056006	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.29553	-118.57997	[EPLAN]PLAN CHECK FOR ROOF MOUNTED 11.4KVA SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(SE3800H-US,SE7600A-US) WITH 40 MODULES USING P320 OPTIMIZERS CONNECTED TO EXISTING 200A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9471	19041-10000-07393	542 E ROSE AVE	90291	11	111B141   333	4240010046	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	33.99853	-118.47286	TI in an existing commercial area.  Installing new lights. T-24 Energy Only. Building Permit: 18016-30000-39270	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9472	19041-20000-18021	7802 W TORREYSON DR	90046	4	159B173   654	5570014020	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.12858	-118.36918	PV1.  Install 19.98 kW roof mounted grid tied PV system.  (54) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9473	13041-20000-14819	1201 N CORNWELL ST	90033	14, 5	132B173  1021	4332028003	PF-1, [Q]R3-1-O	Central, East Los Angeles	Northeast Los Angeles, Wilshire	South Robertson	YES	2033.00, 2164.01	Electrical	Electrical	Apartment			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.05754	-118.20398	NEW FIRE ALARM SYSTEM FOR 2 STORY PLUS 1 SUBTERRAIN GARAGE 7 UNIT APARTMENT. 1 FIRE ALARM PANEL AND  41 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9474	14041-20001-04717	19631 W STRATHERN ST pv1	91335	3	189B117   301	2105004024	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.21572	-118.56123	][] expedited per applicant ][]pv1, roof mounted solar installation, interconnecting with (E)125a main service PNL. (N) 125A load center. ungrounded system, sized @ 6.25 kW DC, with (25) trina solar #tsm-250pa05.18, (25) OP300 power optimizers, (1) solaredge #SE6000a-us-zb-u	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9475	10041-10000-22406	1360 S WESTWOOD BLVD	90024	5	132B153   766	4325016015	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.05594	-118.44192	TENANT IMPROVEMENT OF EXISTING RETAIL BUILDING-NEW ROSS DEPARTMENT STORE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9476	17041-20002-12515	8850 N CORBIN AVE	91324	12	195B117    62	2783025091	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.23146	-118.56211	07-26-2018 Changes to an approved set of plan, changes include update panel schedule to reflect field conditions and addition of daylight sensor. All changes has been clouded as delta D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9477	19041-10000-53940	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	03/02/2020 12:00:00 AM		Issued	03/02/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE INCLUDES NEW LIGHTING,USING EXISTING CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2964 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9478	15041-20000-08230	17965 W MAYERLING ST	91344	12	216B129   475	2601029017	(T)(Q)RE20-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.28804	-118.52425	Installation of new roof mounted solar PV array.  Total system size = 11 kWac.  Single inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9479	10041-20000-14734	1714 N MCCADDEN PL	90028	13	148-5A185  86	5547010011	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			07/29/2010 12:00:00 AM			PC Approved	07/29/2010 12:00:00 AM	ADDRESS	34.1021	-118.3373	revision to approved plans 10041-20000-11897 and 10041-20000-03703. Changes were indicated as delta 9. Changes includes adding two panels 100 amp panels, re-arranging lighting fixtures and receptacles.  Permit already pulled in application 10041-20000-03703 for the revision part.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9480	13041-20000-23924	10029 N GIERSON AVE	91311	12	204B101   548	2745007024	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.25273	-118.61163	PV1 TRANSFORMERLESS INVERTER. 28 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 6.0KWAC. 3 STRINGS FOR 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9481	15041-10000-20359	11755 W CULVER BLVD	90066	11	111B161   899	4233022070	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			06/29/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	33.99772	-118.41618	new fire alarm system 76 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9482	15041-10000-39310	7257 W MELROSE AVE	90046	5	141B181   543	5525012011	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM			PC Approved	11/20/2015 12:00:00 AM	ADDRESS	34.08364	-118.34773	T-24, PC for energy only to an existing restaurant. Adding new lighting and receptacles. Sq ft = 1004	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9483	10041-20000-10639	8000 N HASKELL AVE	91406	6	189B141    52	2206001018	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00, 1275.10	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM	06/14/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.21609	-118.47476	energy plan check printing shop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9484	12041-20000-07390	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.04804	-118.46227	Ti for an existing office. Plan check for energy only (no emergency lighting). 298sqft conditioned area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9485	10041-20000-24010	15750 W STRATHERN ST	91406	6	189B141    84	2206003016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM			PC Approved	12/02/2010 12:00:00 AM	ADDRESS	34.21559	-118.47652	vyleater machine in class i div 1 location	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9486	18041-20001-00409	10918 N ODESSA AVE	91344	12	210B137   825	2680009016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/15/2018 12:00:00 AM	ADDRESS	34.26887	-118.49112	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (2) inverters, (38) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9487	15041-20000-36741	2500 N SILVER LAKE TER	90039	4	148-5A207  26	5439019017	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.10319	-118.26202	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. PV SYSTEM CONNECTED TO A 400A MAIN PANEL.  TOTAL SYSTEM SIZE IS 3KWac. (12)ACM-SUNPOWER X20-250-BLK-B-AC(1) 60A SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9488	18041-10000-12401	340 N BROAD AVE	90744	15	030B209  1045	7418025019	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	33.77392	-118.26049	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURE AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9489	17041-10000-14991	6110-6112 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.09785	-118.32284	TI TO RESTAURANT EXPANSION. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9490	17041-20000-33468	16633 W VENTURA BLVD #505	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for Title 24 only. Project site is an tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,580 sq. ft.Note: Building permit has been issued under 17016-20000-24779	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9491	15041-20000-20546	4863 N DEMPSEY AVE	91436	5	168B141   211	2261006014	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Expired	07/26/2017 12:00:00 AM	ADDRESS	34.1593	-118.47619	Installation of new roof mounted solar PV array.  Total system size = 8 kWac.  Two inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9492	19041-20001-22468	8364 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM				Plan check for lost to approved set of plans. PV1.  Install 2.8 kW roof mounted grid tied PV system for new home construction.  (8) AC modules. Plan check only, permit covered under master application 19041-20000-22468	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9493	16041-10000-08264	672 S SANTA FE AVE	90021	14	124-5A217 135	5164018003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.03577	-118.2301	PC FOR POWER AND ENERGY. CHANGE OF USE  TO FOOD PRODUCTS MANUFACTURING AND T. I BUILDOUT TO INCLUDE 13 KITCHEN SPACES, TWO OFFICES, TWO BATHROOMS, TWO LOCKER AREAS, AND STORAGE SPACES IN AN EXISTING WAREHOUSE BLDG . TOTAL AREA 7316 SQ FT.B3# 15016-10000-26245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9494	18041-10000-47314	2909 S ORCHARD AVE	90007	9	120B197   181	5055010001	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	34.02798	-118.28846	PC FOR T-24 ONLY. SCOPE OF WORK INCLUDES NEW ELECTRICAL SERVICE, PANELS AND CIRCUIT FOR 7- UNIT APARTMENT. B#18016-30000-12774	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9495	14041-10000-35509	800 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.04484	-118.26453	Installation of canopy lights, connect heaters in restaurant. T24. Total area = 1321 sq. ft. Using 2008 compliance forms, building application submitted March 2014	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9496	17041-10000-40441	4610 E VALLEY BLVD	90032	14	135A231   353	5224035007	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.06254	-118.18361	Plan check for Title 24 only in existing space fire damage total load less than 400A. Total area: 12,392 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9497	12041-10000-28373	621 S WESTERN AVE 111-117	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	T24 PER INSPECTORREVISED LIGHTING PLAN BY RELOCATING SOME LUMINAIRES BUT KEEPING THE INSTALLED WATTAGE THE SAME;CHANGE OF USE OF 1ST FLOOR TENAT (7) SPACES FROM RETAIL TO RESTAURANT AND AMUSEMENT ENTERPRISE.  Existing service.  Full Plan Check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9498	15041-10000-40674	2675 E THORPE AVE	90065	1	145-5A219 267	5453005006	R1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.09233	-118.22559	PV1PLAN CHECK ONLY.  FEES PAID UNDER APPLICATION NUMBER 15041 90000 13287.Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9499	18041-20000-44460	10309 W SANTA MONICA BLVD 2nd floor	90025	5	132B157   365	4327017017	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.05936	-118.42182	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 2000 SQFT AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9500	15041-10000-13209	12547 W SHERMAN WAY STE A	91605	2	183B161    18	2324003007	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.20136	-118.40673	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 1928 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9501	16041-20000-29533	11748 W RIVERSIDE DR	91607	2	168B169   503	2355019037	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.15739	-118.38936	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE BUILDING. 1649 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9502	17041-20000-00737	8242 N CELIA PL	91406	6	192B133   525	2204001043	(Q)RD5-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	PIN	34.22030223	-118.50784381	PV1.  Install 4.06 kW roof mounted grid tied PV system.  (14) modules with 3.8kW rated central inverter.  Power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9503	14041-10000-04354	300 WORLD WAY TER 3DUTY-SHOP	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	33.94502	-118.40714	T.I. - TENANT BUILD-OUT OF (E) RETAIL SPACE AND STORAGE ROOM AT LAX. ( 900 SQ.FT.)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9504	19041-30000-48292	430 S FULLER AVE TOWER 40	90036	4	135B181   326	5509005009	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	04/02/2021 12:00:00 AM		Issued	04/02/2021 12:00:00 AM	ADDRESS	34.06661	-118.35291	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW SERVICE UPGRADE TO 4000AMP, 120/208V 3 PHASE. REPLACING ALL UNIT PANELS NO NEW LOADS. TOWER 40	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9505	13041-20000-34649	5610 N VAN NUYS BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.17254	-118.44836	THIS PLAN CHECK ONLY COVERS NEW 200A PANEL AND FEEDER FROM EXISTING METER FOR A FIRST TIME TENANT. PERMIT IS ON APPLICATION#: 13041-90000-32349 **FULL PLAN REVIEW IS REQUIRED FOR THE CONTRACTOR INSTALLING THE LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9506	16041-20000-07736	7858 N LANKERSHIM BLVD	91605	6	189B169   482	2311015001	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.21372	-118.38757	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to an auto repair shop. Total lighting area = 2,184 sq. ft.Note: Building permit has been issued under 14014-20000-04435	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9507	18041-20000-18973	11812 W SAN VICENTE BLVD Ste 510	90049	11	129B145   113	4265018016	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.0528	-118.4684	Existing commercial highrise office remodel.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9508	15041-10000-12017	200 WORLD WAY TERM 2-# 235	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	AT LAX, INSTALLATION OF ILLUMINATED SIGNS FOR TENANATPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9509	14041-20000-18894	10925 N NOBLE AVE	91345	7	207B145    71	2615005005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.26751	-118.46015	pv1 single family dwelling. total system size 3.8kw ac using transformerless inverter. using standard plan. using power optimizers. total of 18 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9510	10041-20001-03987	7217 W FOOTHILL BLVD suite-311	91042	7	202-5A199 386	2568012025	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM			Ready to Issue	03/16/2010 12:00:00 AM	ADDRESS	34.24894	-118.28897	TENANT  IMPROVEMENT  Energy, emergency. Change to previously approved plan of 10041-20000-03987 adding some lighting and receptacles in medical office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9511	16041-10000-28715	11777 W SAN VICENTE BLVD #650	90049	11	129B145    59	4401017026	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.05331	-118.46832	TI NON-BEARING INTERIOR PARTITIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9512	10041-10000-08670	338 S WESTERN AVE units A &B	90020	4	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.01	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	09/17/2010 12:00:00 AM	ADDRESS	34.06777	-118.30889	First tenant in new retail spaceS- COMBINING TWO SPACES TO FORM ONE TENANT SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9513	16041-30000-35024	2022 E VIOLET ST	90021	14	123A217    94	5166012037	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.0324	-118.23138	Title 24 plan check only.  Remove HID fixtures and replace with new LED fixtures.  Total area = 27,180 sq. ft. (indoor) + 22,215 sq. ft. (outodoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9514	14041-20000-05728	9719 W MUSTANG WAY	91040	7	204B181   124	2549025033	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.25851	-118.34341	Roof mounted PV system with Optimizers, total system size 4.25KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9515	18041-20002-23094	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM			PC Approved	07/23/2019 12:00:00 AM	ADDRESS	34.08901	-118.34188	7/23/19changes to an approved set of plans.  changes to reflect field conditions.  all changes are noted delta 22.this is plan check only.  ((((Plan check for power and energy change of use from part of office building to Medical Clinic 4th, 5th, and 6th Floor. T.I. to existing service equipment. Total area: 47,413 sq ft.)))) B#18016-20000-15553	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9516	17041-10000-30454	601 S ARDMORE AVE 100	90005	10	135B193   875	5503025014	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.06322	-118.30183	PC FOR POWER AND ENERGY. NEW LIGHTING IN DINING AREAS AND NEW INDUCTION COOKERS FOR SHABU STATIONS. ALTERATION IN ASSEMBLY OCCUPANCY GREATER THAN 100. TOTAL AFFECTED AREA IS 3510 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9517	19041-20001-36745	5727 N CANOGA AVE BLDG 8	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	10/14/2020 12:00:00 AM	ADDRESS	34.17529	-118.5978	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9518	18041-20000-22552	550 S HOPE ST suite 1675	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	Plan check for Title 24 Energy only in existing space high-rise building T.I. Total area: 7125 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9519	16041-20000-05822	7048 N MCLAREN AVE	91307	12	183B097   304	2026007011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.19868	-118.62437	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (17) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9520	16041-20000-09414	13051 N SAN FERNANDO ROAD	91342	7	222B145   116	2604011032	C2-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Closed	03/30/2016 12:00:00 AM	ADDRESS	34.30715	-118.46993	Plan check for energy only. TI to existing retail space. New lighting (incl. emergency). 772sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9521	16041-20001-03746			1	129A203   285	5137020020	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	PIN	34.04714272	-118.27446556	REVISIONS TO AN APPROVED SET OF PLANS.  EM LIGHITNG ONLY.  THIS IS PLAN CHECK ONLY.FULL PC FOR POWER AND ENERGY TO AN (E) COMMUNITY CENTER. SCOPE INCLUDES UPDGRADING THE MAIN SWITCHBOARD TO 800A 120/208V 3PHASE 4 WIRE, AND ADDING NEW PANELS AND LOADS. TOTAL AFFECTED AREA IS 39,362 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9522	18041-20000-35628	12232 N NUGENT DR	91344	12	219B129   616	2606029018	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.29358	-118.51444	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9523	14041-20000-22221	5533 N ALLOTT AVE	91401	4	174B157   721	2344005012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.17113	-118.42817	PV1Central/String inverterter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6800kW.(1) SolarEdge SE3800A-US transformerless inverter(1) SolarEdge SE3000A-US transformerless inverter(32) REC Solar REC260PE pv modules(32) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9524	19041-20000-52891	12717 W GAULT ST	91605	2	183B161   182	2324019017	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.19946	-118.41004	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 23.12 KW DC/20.351 KW AC CEC. SOCPE OF WORK CONSISTS OF (68) PV MODULES WITH (2) INVERTERS (11.4 KW) (10 KW) AND A 125A LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9525	11041-10000-05969	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Approved	03/30/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	title 24 and emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9526	16041-30001-26284	1300 N BEVERLY ESTATE DR	90210	5	147B157   335	4356020007	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	05/07/2018 12:00:00 AM	ADDRESS	34.0959	-118.42732	Plan check for Single Family Dwelling for 1000A Service at 120/208V 2 story buildingNote: Electrical Permit was pulled under 16041-40000-26284. This is plan check onlyB#14010-10000-04178	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9527	15041-10000-23654	1063 W VIA CORDOVA	90732	15	021B193    75	7445017014	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	33.75467	-118.30196	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9528	13041-20000-06151	19812 W REDWING ST	91364	3	174B117   508	2164010027	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.17063	-118.5642	new 17.64kw pv system for an exisiting single family residence. CHanges to plan. Permit fee under inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9529	12041-20000-00571	11928 W VENTURA BLVD	91604	2	162B169   193	2369016009	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM			PC Approved	01/10/2012 12:00:00 AM	ADDRESS	34.14297	-118.39179	energy plan check pizza crust existing service	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9530	15041-10000-38812	121 W 115TH ST	90061	15	087A203   368	6087001018	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	33.93021	-118.27466	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) KYOCERA 2656 MODULES(1) ABB PVI-3.0 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9531	18041-10000-38322	4925 S HOOPER AVE	90011	9	111A211   225	5107025016	RD2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	33.99819	-118.2523	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9532	11041-10004-23452	20600 W VENTURA BLVD South-1-217	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			05/28/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.16715	-118.58204	DELTA 12 CHANGES TO PERMITTED SET OF PLANS : Lighting Plan General Note #4 was modified ; On sheet ES7.1, CIRCUITS WERE ADDED TO PANEL  LC-S1 and a panel LC-S2 WAS ADDED WITH ONE CIRCUIT  PLAN CHK ONLY South Building of a New 217 unit Apartment building.  Building Permit is on 11010-10000-01956	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9533	11041-20000-14990	10250 W SANTA MONICA BLVD #54	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR RETAIL SPACE (UNIT #54)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9534	13041-20000-25302	4239 N STILLWELL AVE	90032	14	145-5A237  61	5309015004	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.09416	-118.16377	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.6 KW AC USING 15 MODULES. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9535	12041-10000-28435	3972 N MISSION ROAD	90031	1	138A227    78	5211019025	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	34.07363	-118.19647	COMMERCIAL KITCHEN IN (E) WAREHOUSE,  KITCHEN EQUIP., CEILING & LIGHT FIX., INTERIOR FINISH, NEW RESTROOMS.  WALK-IN COOLER UNDER DEFERRED SUBMITTAL.PLAN CHK IS FOR TITLE 24  ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9536	18041-10001-39943	1654 S GREENFIELD AVE 1-8	90025	5	129B153   553	4324030010	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM			PC Approved	10/28/2019 12:00:00 AM	ADDRESS	34.04935	-118.4417	PLAN CHECK ONLY. DELTA 1 CHANGES TO APPROVED SET. CHNEGES TO MODULES TYPE, RELOCATING DISCONNECT PER INSPECTOR REQUEST AND RELOCATING ROOF EQUIPMENT LOCATION. ((PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 28.8KVA SYSTEM CONSISTING OF 2 INVERTERS (SE 14.4K-US) WITH 88 MODULES USING P320 POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9537	18041-10000-28378	7959 W MELROSE AVE	90046	5	141B177   531	5527013002	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.08393	-118.36303	PLAN CECK FOR TITLE 24 ONLY FOR - Interiror alterations which include milwork and new non-structural partitions of (E) commercial space and change of use from beauty salon/parlor to take-out restaurant. - TOTAL AFFECTED AREA = 786 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9538	13041-10001-12811	1490 W 7TH ST	90732	15	015B193   350	7452034035	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	33.73806	-118.30936	SUPPLEMENTAL  PC & PERMIT TO INCLUDE SCHEDULE AND LOADS FOR  HOUSE PANEL AND UNACCOUNTED CKTS ON ORIGINAL APPLICATION. INCLUDE LOADS IN SERVICE LOAD CALCULATIONS. (FY)ORIGINAL PC UNDER 13041-10000-12811. pc for power and energy. NEW ONE STORY COMMERCIAL BUILDING. SUITE A DENTISTS OFFICE (medical), SUITE B--OFFICE SHELL ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9539	19041-10000-42244	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	01/13/2022 12:00:00 AM	ADDRESS	34.07125	-118.35662	"TI IN AN EXISTING COMMERCIAL AREA IN BULDNG ""O"" AT THE GROVE. INSTALLING LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 3,555 SFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9540	14041-10000-25516	10019 N SUNLAND WAY	91040	7	204B181   403	2549027009	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.25481	-118.34314	Standard plan PV1 roof-mounted system including (1) 6KW inverter and (29) Canadian Solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9541	12041-20000-01689	11040 W MAGNOLIA BLVD	91601	4	171B173   607	2353006012	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20, 1254.00	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.16478	-118.37197	T-24 lighting plan check for remodeled restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9542	19041-20000-13505	2501 W 7TH ST	90057	1	133-5A201 232	5141007014	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	08/06/2021 12:00:00 AM	ADDRESS	34.05881	-118.28157	Plan check for power and energy. Project site is a new 5-story charter school. Project scope is a new 800-amp service and a total lighting area of 33258 sq. ft.Note: Building application has been generated under 18010-10000-06262	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9543	19041-10000-28763	1174 S LA BREA AVE S2	90019	10	132B181  1219	5084021016	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.054	-118.3433	PC for Methane mitigation system (Lever 4), 1 fire alarm panel, 1 power supply and 5 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9544	13041-20001-31214	12727 W SHERMAN WAY	91605	2	183B161    11	2324004004	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	10/23/2014 12:00:00 AM	ADDRESS	34.20137	-118.41091	Changes from previously approved plans.  Change in feeder interconnection with the service panel and lighting.  Plan check for power and energy.Note: Permit is under the original application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9545	14041-10002-15469	6118 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	34.0978	-118.32305	NONSTRUCTURAL INT REMODEL - COMBINE EX RETAIL & RESTAURANT TENANTS INTO ONE RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9546	16041-10001-03140	8985 W VENICE BLVD #B-1	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.02733	-118.39241	PC FOR CHANGES TO APPROVED SET. CHANGES NOTED DELTA 9 ON PLANS. ADDED HWP AND REVISED CIRCUITS TO ROOF PLAN. UPDATED PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9547	18041-10000-06140	5800 W SUNSET BLVD BLDG-20-21	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.09728	-118.31693	INSTALLING FACADE LIGHTING FOR BUILDING 20-21-NORTH,  EAST, WEST ELEVATIONSPLAN CHECK IS FOR TITLE 24 OUTSIDE LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9548	13041-10000-30383	5914 N COLFAX AVE	91601	2	177B169  1022	2339009035	RD3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.17805	-118.3876	PV1. NON STANDARD MICROINVERTER PLAN. 1 STORY HOUSE. SYSTEM SIZE: 1.2KW SYSTEM.(5) CANADIAN SOLAR MODULES CS6P-240P(5) ENPHASE M215 MICRO-INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9549	17041-20000-42660	3711 S GLENDON AVE 1-21	90034	5	117B161   241	4252029038	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Issued	11/28/2017 12:00:00 AM	ADDRESS	34.01941	-118.41043	REPLACEMENT OF FIRE ALARM PANEL AND ADDITION OF 1 DEVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9550	19041-10000-24028	300 WORLD WAY TEMP	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	09/07/2022 12:00:00 AM	ADDRESS	33.94502	-118.40714	Power plan check for temp' power located in LAX Terminal 3. Scope includes (1) 800-amp distribution panel and other equipment. fault current, voltage drop, and load calcultion included.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9551	15041-10000-32600	333-339 W WASHINGTON BLVD	90015	14	124-5A205 269	5126012013	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.0334	-118.26945	PC FOR POWER ONLY. SCOPE INCLUDES SERVICE UPGRADE TO AN 800A 120/240V 3PHASE 4 WIRES SERVICE ON AN EXISTING COMMERCIAL BUILDING (RETAIL & MARKET).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9552	19041-10000-02074	5700 W VENICE BLVD	90019	10	126B177   494	5064020003	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.04314	-118.36234	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9553	15041-10000-18372	11743 W GOSHEN AVE	90049	11	129B145   569	4265010191	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			06/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.04953	-118.46283	installation of new fire alarm system for 4-story 13 units apartment building.. with 47 and one fa device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9554	15041-20000-14849	211 S LA BREA AVE	90036	5	138B181  1307	5513022012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Closed	02/23/2016 12:00:00 AM	ADDRESS	34.07066	-118.34433	Plan check for power only. Plan check is for the power distribution equipment only; no new loads are being plan checked. Project site is an existing commercial building. Project space is being divided into two spaces. Project scope is the installation of a new 600-amp service, and the installation of (1) 400-amp panel; no new loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9555	15041-20001-18403	9325 N LA SHELL DR	91042	7	198B201   401	2572048029	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	34.23779	-118.27601	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 11KW AC USING 2 CENTRAL INVERTERS. SYSTEM USES POWER OPTIMIZERS. TOTAL OF 40 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9556	17041-10000-18815	1800 E 4TH ST	90033	14	127-5A221 186	5174023017	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.04288	-118.21909	PC for energy only, Outdoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 9,150 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9557	10041-10002-19799	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	33.93195	-118.41136	Replace existing 1600 ampere service with new 1600 ampere service rate 100000 amperes.  All other circuits and equipment covered on existing permits 10041-10000-19799, and 10041-10001-19799.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9558	13041-10001-26977	3781 S CIMARRON ST	90062	8	117B189   568	5035028032	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	PIN	34.01813325	-118.31635973	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 2 STORY HOUSE. TRANSFORMERLESS INVERTER. UNGROUNDED SYSTEM. SYSTEM SIZE: 1.715 kW.(7) YINGLI # YL245P-29b(1) POWER-ONE # AURORA PV1-3.0-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9559	19041-10000-45919	20751 W SUPERIOR ST	91311	12	201B109   200	2748004051	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.24646	-118.58589	NEW FIRE ALARM SYSTEM WITH 57 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9560	11041-20002-00534	2850 W RIVERSIDE DR	90039	4	151-5A207  63	5438025011	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	11/23/2011 12:00:00 AM	ADDRESS	34.10998	-118.26339	Plan check for revisions of an approved set of plans.  Threvisions are the use of an isolation transformer due to the use of transformerless inverters.  <<<<<Plan check for revision to approved plans. Revision to point of connection from supply side to load side. Derate main overcurrent protection from 400A to 200A.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9561	15041-10001-27664	777 S SANTA FE AVE TOWER	90021	14	124-5A217 323	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	34.03354	-118.23024	.  PLAN CHECK FOR POWER AND ENERGY BUILDING APPLICATION UNDER 14016-10001-21080Revisions to permitted set of plans: Tower building is only 5stories tall but building submittal  indicated it as a high rise and was plan-checked as such. Changes to the plans include having the elevators on the EM board and removing transfer switch for legally required board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9562	19041-10000-35670	2807 S POTOMAC AVE	90016	10	123B181  1372	5057008003	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.03081	-118.34413	PV 1 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 5.0 KW SOLAR SYSTEM AND (19) OPTIMIZERS AND MODULES. TOTAL SYSTEM SIZE IS 5.0 KWAC/ 5.89 KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9563	13041-20000-26856	10635 W SANTA MONICA BLVD Suite 130	90024	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	PIN	34.05365874	-118.43036269	T24 FOR EXISTING OFFICE BUILDING. SCOPE OF WORK ON SUITE 130. TOTAL SQRFT 940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9564	17041-20001-44071	16111 W MEADOW VIEW DR	91436	5	165B141   561	2285014033	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	34.15014	-118.48406	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array for SFD.14.08kW ungrounded system. (44) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9565	19041-10000-03977	649 S TOWNE AVE	90021	14	126A213   203	5147027047	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Issued	06/26/2019 12:00:00 AM	ADDRESS	34.04021	-118.24479	SERVICE UPGRADE 200 AMP TO 800 AMP. CORE AND SHELL ONLY. NO NEW LOAD ADDED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9566	15041-10001-25611	15232 W FOOTHILL BLVD	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.32292	-118.46695	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 3.92 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(12) MODULES: SUNPOWER SPR327NE(1) INVERTER: ABB PVI-3.8-OUTD-US-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9567	19041-20000-36222	18050 W VANOWEN ST	91335	3	180B125    48	2122028013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	12/09/2021 12:00:00 AM	ADDRESS	34.19372	-118.52686	Power and lighting for change of use from church to child care facility and early learning center.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9568	16041-20000-40945	10264 ANGEL LANE	91331	7	204B165   422	2537004032	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25733625	-118.40479629	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9569	17041-20000-15614	4438 E HUNTINGTON DR SOUTH	90032	14	141A229    36	5214008037	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.08247	-118.18941	Plan check for energy only. New office building. 569sqft. Indoor lighting (incl. emergency) and outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9570	17041-10000-05715	14006 W RIVERSIDE DR STE 245A	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Issued	05/23/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only in existing space T.I. retail. Total area: 3,609 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9571	14041-20001-10257	9906 N AURA AVE	91324	12	201B117   109	2726021003	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.25032	-118.55431	EXPEDITE PER APPLICANT REQUEST(((PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 9kW(2) SolarEdge #SE3800A-US-ZB-U transformerless inverter(36) Canadian Solar #CS6P-250PX pv modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9572	19041-20001-15670	4920 N VAN NUYS BLVD pv2	91403	4	169-5A151  47	2248007139	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.15995	-118.4485	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CLOUDED DELTA 1 CHANGES ONLY. SCOPE OF WORK INCLUDES 1 ADDITIONAL CHINT SOLAR PV MODULE AND P730 OPTIMIZER AND CHANGE TO ROOF PV MODULE LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9573	10041-10000-24478	16461 W VENTURA BLVD	91436	5	168B137   331	2260009044	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	07/29/2011 12:00:00 AM	ADDRESS	34.15772	-118.49199	Ti for a new CVS pharmacy. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9574	17041-10000-17550	5155 E OAKLAND ST	90032	14	144A235   204	5219001003	RD3-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.08843	-118.16963	T24 ONLY. REPALCE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING:14000 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9575	16041-20000-09098	9815 W NATIONAL BLVD PV-1	90034	5	123B165   902	4311003022	C2-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.03155	-118.40025	Zero fee per Senate Bill 1222Install a roof-mounted solar array on a gas station canopy (over filling pumps).Interconnect with 1200A MSP.System size: 45kW (15+15+15). Ungrounded system.(180) 245W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9576	17041-10000-35234	633 W 5TH ST # 6780	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS TOEXISTING WORK /OFFICE SPACEPLAN CHECK S FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9577	10041-20000-19394	1420 N COIL AVE	90744	15	036B213    16	7426029007	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	33.79347	-118.24241	a/c portion of pv system original permit 10041-20000-14772	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9578	15041-10000-06326	3515 W MONT CLAIR ST	90018	10	123B189  1039	5051017006	R1-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.02976	-118.32292	PV1, INSTALL 3.9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(12) MODULES: SNPOWER 327 W ;(1) inverter: ABB PVI-3.8-OUTD-US--A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9579	18041-20000-41533	8827 N VAN NUYS BLVD	91402	6	195B149   369	2653001007	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Apartment			10/30/2018 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Closed	09/24/2021 12:00:00 AM	ADDRESS	34.23074	-118.45052	new apartment building 9 unit 600 amp service.  plan check for power and energy.see comments.....	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9580	12041-10001-15097	12706 W GAULT ST	91605	2	183B161   286	2324018085	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM			PC Approved	08/15/2012 12:00:00 AM	ADDRESS	34.19918	-118.40978	PLAN CHECK FOR NEW 5.46 KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING TRANSFORMERLESS INVERTER. EXISTING PERMIT UNDER #12041-20000-15097.  PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9581	18041-30000-15567	801 S FIGUEROA ST 6th Floor-Restrooms	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site are the 6th floor restrooms of a commercial building. Project scope is a tenant improvement. Total lighting area = 720 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9582	17041-10000-07545	7000 W ROMAINE ST	90038	4	144B181   631	5532010050	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.08879	-118.34215	PC FOR ENERGY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL ARAE 36720 SQ FT. /OUTDOOR/	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9583	16041-10001-12483	4501 W MARTIN LUTHER KING, JR BLVD #H	90008	10	117B181   239	5046034014	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	34.01789	-118.34601	TI TO NAIL SHOP - NEW LIGHTING - PC FOR T24 ENERGY ONLY. PERMIT ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9584	14041-20000-11291	16410 W ARMSTEAD ST	91344	12	213B137   286	2610026010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Expired	05/24/2016 12:00:00 AM	ADDRESS	34.28202	-118.48951	Roof mounted PV system with transformerless inverters.  System size 6.5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9585	18041-20000-42082	105 S DOHENY DR 1-6	90048	5	138B169   377	4335007123	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	07/17/2020 12:00:00 AM	ADDRESS	34.07503	-118.39011	new fire alarm system 129 devices with new facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9586	17041-10000-30470	6351 N SEPULVEDA BLVD	91411	6	180B145   798	2242009023	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.18614	-118.46641	TITLE 24 PLAN CHECK TO REMOVE EXISTING (7) HID FIXTURES AND REPLACE WITH LED FIXTURES. 24600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9587	18041-10003-13640	835 W JEFFERSON BLVD	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM			PC Approved	08/15/2018 12:00:00 AM	ADDRESS	34.02414	-118.28458	"DELTA 5 CHANGES TO THE APPROVED PLANS FOR UPDATING LIGHTING PLAN WITH FIXTURE TYPE, CONTROL DETAIL AND MANUFACTURER ONLY.  <<<FULL PLAN CHECK (POWER + ENERGY) FOR 1ST TIME TENANT (AND ALSO CHANGE OF OCCUPANCY) FROM ""RESTAURANT"" TO ""RETAIL"", FOR ABERCROMBIE & FITCH. INSTALL (1) 225A PANEL WITH ITS CIRCUITRY, TOTAL AREA: 2,736 SQ.FT>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9588	15041-20000-25092	16226 W DICKENS ST	91436	5	168B137   536	2284004046	R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.15541	-118.4866	Plan check for a PV1 roof-mounted PV system. System size is 9.8 kWac and consists of (2) inverters, (44) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9589	12041-10000-12963	11300 W OLYMPIC BLVD	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	ADDRESS	34.03792	-118.44134	Remodel of an existing office building, on the 9th floor, suite 900.  No new load, remodel uses all existing circuits.  Permit was previously pulled on a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9590	14041-20000-18383	8645 N LANGDON AVE	91343	6	195B145   550	2654018022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.22786	-118.46998	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MAIN MSP.(1) SOLAREDGE SE5000 INVERTER(24) TRINA SOLAR TSM-255 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9591	19041-20001-49915	12933 W ADMIRAL AVE	90066	11	105B157   383	4223005006	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Expired	09/11/2023 12:00:00 AM	ADDRESS	33.98503	-118.4298	PV1. INSTALL 7.35 KW DC PV SYSTEM WITH (21) MODULES AND MICROINVERTERS. INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-49915	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9592	17041-10000-19690	350 S GRAND AVE 25 & 26 FL	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.05173	-118.2522	TI TO 25TH AND 26TH FLAOORS.UPGRADE LIGHTING IN A FEW OFIFICES AND CONFERENCE ROOMS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9593	14041-10000-26344	8122 N VAN NOORD AVE	91605	2	189B161    54	2304013023	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Expired	11/23/2016 12:00:00 AM	ADDRESS	34.21852	-118.41535	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE 10.71KW DC.(42) KYOCERA KD255GX(1) SOLAR SE5000A(1) SOLAR SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9594	11041-20000-25080	15600 W MULHOLLAND DR Phase 1	90077	5	159B145   570	4378001027	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	1416.00, 2622.00	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.12928	-118.47146	Plan check power and energy for library 23000 sq. ft remodel(PHASE I)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9595	18041-10000-12476	6820 W ROMAINE ST	90038	4	144B185   975	5532012026	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Issued	06/18/2018 12:00:00 AM	ADDRESS	34.08879	-118.33925	PC FOR POWER ONLY. NEW 1600A SERVICE IN EXISTING MANUFACTURING. RECONNECT EXISTING PANELS.  NO NEW LOAD ADDED AT THIS TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9596	15041-10000-23511	7083 W HOLLYWOOD BLVD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM			Corrections Issued	07/23/2015 12:00:00 AM	ADDRESS	34.10173	-118.34439	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9597	10041-20000-25670	8900 N DE SOTO AVE Bld. #101	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	01/12/2011 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	34.23162	-118.58832	T.I. to existing building.  Install general/emergency lighting in Tube Bend and Welding area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9598	13041-20000-25590	7640 N HASKELL AVE	91406	6	186B141    32	2206012029	(Q)CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.20957	-118.47474	"PV2. "" $0 permit fee is due to the 2012 Senate Bill No. 1222""  COMMERCIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM. TOTAL SYSTEM SIZE 100KW DC. USING (4) TRANSFORMERLESS INVERTERS SMA 20000TL. SUPPLY SIDE POINT OF INTERCONNECTION."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9599	13041-10000-36248	801 S FIGUEROA ST 18TH FLOOR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.04789	-118.26153	PLANCHECK FOR T24 ENERGY ONLY. NO CHANGE IN OCCUPANCY. OFFICES. HIGH RISE. 18TH FLOOR. 1920 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9600	17041-20000-17726	1441 N EASTLAKE AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Info Complete	06/29/2017 12:00:00 AM	ADDRESS	34.06118	-118.20631	Plan check for power and energy. TI to Auditorium 2965 - new lighting (incl. emergency) and power. 3,159sqft. Place of assembly per Article 518.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9601	18041-20000-10466	11835 W OLYMPIC BLVD Ste 1065E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.03301	-118.45119	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,592 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9602	19041-10000-53200	1149 S BROADWAY 9th Floor	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	04/28/2022 12:00:00 AM	ADDRESS	34.03859	-118.26015	Energy pc only for TI, Area of scope (248)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9603	13041-10000-01592	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	DODGERS STADIUM SCOREBOARDS-ONE IN LEFT FIELD AND ONE IN RIGHT FIELD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9604	19041-20002-04250	10245 N QUILL AVE	91040	7	204B189   746	2560022003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.25551	-118.31682	07-19-2019 Changes to an approved set, Plan check for PV roof mounted system and battery energy storage, PV System size: 5.525KW with 17 PV Modules and 1 inverter 5.0KW with 1 Tesla battery 13.5KWH.Fess $0.00 due Caifornia Senate Bill 1222 and AB1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9605	14041-20000-15811	2479 N LANTERMAN TER	90039	4	150A205   319	5432011014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.10413	-118.27037	PV1.  Install 7.66 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9606	13041-10000-30652	2080 S CENTURY PARK EAST Suite 400	90067	5	132B161    39	4319001014	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.05884	-118.41206	plan check for power and energy. TI for a medical office, surgery equipment.5044 sq ft. suite 400	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9607	11041-20001-26428	2936 W 8TH ST PV-1	90005	1	132B197   502	5077023024	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.05758	-118.29013	Addition of delta to wye-grounded transformer (150kVA) and associated equipment. New 25.92 KW roof mounted PV system for a church with service upgrade to 400 amperes, reconnect existing loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9608	13041-10000-29529	4827 N OAK PARK AVE	91316	5	168B133   178	2289004010	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.15857	-118.50467	PV1.  Install 11 kW DC roof-mounted solar array, interconnect with main service panel.  inverter: Fronius IG Plus V 10.0 . 44 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9609	19041-10000-28077	10008 S AVALON BLVD 1-6	90003	8	091-5A207 103	6050036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	10/27/2021 12:00:00 AM	ADDRESS	33.94497	-118.26451	Building 3 of 5: Note. 5 applications under 1 plan, main service located under this buildingFull plan check for power and energy for service upgrade to 600A for 22 residential units split up into muiltple buildings. Scope of work includes a new 600A serivce, new resedintial panels, and a new 600 A distribution board. Note building has provided 5 different building numbers for each building, 5 applications were genrated  under one planELECTRICAL Buiding 1: 19041-10000-27892Building 2: 19041-10000-28073Building 3: 19041-10000-28077*Building 4: 19041-10000-28079Building 5: 19041-10000-28081	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9610	09041-10001-19704	5331 E HUNTINGTON DR NORTH BLGD 1	90032	14	145-5A237 252	5309017020	(T)[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Apartment			03/17/2011 12:00:00 AM	03/17/2011 12:00:00 AM		Permit Finaled	01/24/2012 12:00:00 AM	ADDRESS	34.09124	-118.16464	New low-income housing project.  3 separate buildings w/ 25 units totals.  Bldg1 - 4 units - Permit # 09041-10001-19704,       Bldg 2 - 15 Units - Permit # 09041-10000-19704  &   Bldg 3 - 6Units - Permit # 09041-10002-19704  <<<<<THIS PERMIT IS FOR BUILDING #1>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9611	16041-20000-42942	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for power only per applicant request. Project site is an existing commercial building. Project scope is the installation of a new flow test pump.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9612	13041-10000-31305	7502 N JOLENE CT	91605	2	186B165   306	2307023***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.20695	-118.40101	PV1.  Install 6.25 kW DC roof-mounted PV system, interconnect with main service panel.  Transformerless inverter: SolarEdge SE6000A-US.  25 modules: Trina Solar TSM-250PA05.18	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9613	19041-20000-28647	1371 N AVENUE 46	90041	1	156A221   324	5474037001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1862.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.12016	-118.2159	pv1install roof mounted pv system sized 9.1KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9614	19041-20001-04657	7032 S RAMSGATE PL	90045	11	102B173   397	4103011016	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			02/13/2019 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	33.97338	-118.37312	Revisions to approved set of plans.  Changes made to sheets E0.5, E2.1, and E2.2 only.  Removal of time clock control from scope of work.  Outdoor lighting updated to photocell control.  Addition of partial-off occupancy sensor control of corridors.  (((pc change include adding 1 inverter, emergency ltgs and update T-24 forms. change marked delta 1. original electrical permit #: 16041-20000-32337)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9615	14041-20002-16313	19800 W VENTURA BLVD	91364	3	174B117   369	2164011027	(T)(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.17216	-118.56413	3/19/2015 Changes to an approved set of plans. Changes include the addition on a 200 A fuse per inspector's request. Changes have been clouded and labeled as Delta 9.PLAN CHECK FOR POWER AND LIGHTING - TOTAL AREA = 15,140 SQ FTNEW TENNANT IMPROVEMENT - NEW LIGHTS AND POWER DISTRIBUTION THROUGHOUT, REPLACE EXISTING BACK UP GENERATOR.  EXISTING COMMERCIAL LOW-RISE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9616	13041-10000-08139	19701 S VERMONT AVE	90502	15	057B197    41	7351034025	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	33.85153	-118.29072	NOTE: APPL TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE PLAN CHECK COUNTER. PLAN CHECK FOR TITLE 24 FOR A TENANT IMPROVEMENT. 6584 SQUARE FEET, LOAD < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9617	19041-20000-41036	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9618	15041-10000-14005	17810 W SIMONDS ST	91344	12	210B129    29	2711017014	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.27623	-118.5221	PV1, Install 10 kW DC roof-mounted solar array, interconnect with service panel.  2 new 200 amp subpanel. 40 micro inverter (m215-60-2ll-s22-ig):  and modules trina  solar tsm-250pa05.05 250 W.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9619	10041-20000-13174	3375 S HOOVER ST E204	90007	8	120A201     4	5039020030	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.02495	-118.28448	T.I. to existing building (USC) in office rooms 202, 201.  Install general and emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9620	14041-10000-25013	3912 N LAUREL CANYON BLVD 1-36	91604	2	162B165   455	2369019032	R4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Expired	04/12/2017 12:00:00 AM	ADDRESS	34.14145	-118.39429	PV2, INSTALL 22950 W DC ROOF-MOUNTED SOLAR ARRAY ON AN  APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL. LOW FEES DUE TO 2012 SENATE BILL NO. 1222(90) MODULES: CANADIAN SOLAR CS6P-255P(2) INVERTER: SMA AMERICA SB7000US-12 AND ONE SMA AMERICA SB6000US-12	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9621	13041-10001-05026	8131 S TRUXTON AVE	90045	11	099B165  1064	4107004019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	33.96422	-118.39359	(((changes to approved set of plans: REC245 TO REC250(PE)BLK)))pv1 for 1-story house.  2.45 KW installation.  {10 modules - REC 245 PE BLK} {Microinverter: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9622	10041-10000-05877	7001 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	06/21/2010 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	"Proposed 34.5KV DuctBank in LAWA at TAXI WAY ""S"".  Approx 1600'."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9623	12041-10000-02602	13130 W ALBERS ST	91401	5	174B157  1138	2345005033	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.17012	-118.41923	Plan check for 7.75KW roof mounted photovoltaic system single family dwelling. Permit for PV system and includes upgrading 225A main service panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9624	19041-20000-30375	6252 N VENTURA CANYON AVE	91401	2	177B157   180	2330010017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	09/07/2019 12:00:00 AM	ADDRESS	34.18461	-118.42893	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 5.28 KW DC/5.04KW AC. SCOPE OF WORK CONSISTS OF (16) PV MODULES WITH (16) MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9625	15041-10000-23588	302 N AMALFI DR	90402	11	123B129   646	4410023002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.03212	-118.51465	PV1 INSTALL 6540 KW DC ROOF-MOUNTED SOLR ARRAY ON A SINGLE FAMILY HOUSE. UNGROUNDED NVERTER. (20) MOUDULES: SUNPOWER SPR-E20-327  (1) INVERTER: SMA AMERICA SB6000TL-US-22 240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9626	13041-20000-12597	22350 W GERMAIN ST #3	91311	12	207B101   161	2723011***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/16/2013 12:00:00 AM	ADDRESS	34.2624	-118.61442	ROOF MOUNTED SOLAR ELECTRIC SYSTEM  7 KW. PV2 TOWN HOME. NO PERMIT TO BE ISSUED UNDER THIS APPLICATION. PERMIT ALREADY ISSUED UNDER EXPRESS PERMIT # 13041-20000-10404.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9627	10041-20000-19227	7715 W SUNSET BLVD	90046	4	147B177   988	5551022012	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.09823	-118.3578	Plan check T24 Energy for TI in existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9628	14041-20000-22810	7231 N MADORA AVE	91306	3	186B113   844	2115011042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.20232	-118.56632	PV1 SINGLE FAMILY USING 2 CENTRAL INVERTERS TRANSFORMERLESS TYPE. USING STANDARD PLAN. TOTAL SYSTEM SIZE 7.2KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9629	15041-10000-07434	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Expired	07/14/2017 12:00:00 AM	ADDRESS	33.79173	-118.23549	Replace existing UPS system with new (2) 60kVA UPS and (2) 75 kVA transformers, as well as adding distribution panelobards in UPS room.Original plan check expired under 13041-10000-09267.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9630	16041-10001-20551	2733 S MCCONNELL DR	90064	5	126B165   270	4308006008	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.04357	-118.40271	NOTE EXPEDITE PER APPLICANT. PV1, NEW ROOF SOLAR SYSTEM USING MICROINVERTERS, ENPHASE. (30) MICROINVERTERS, ENPHASE (30) LG ELECTRONICS LG315N1C-G4. ALL MODULES INTERCONNECTED TO A LOAD CENTER, 100 AMP. TOTAL SYSTEM SIZE IS 8.4KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9631	10041-10000-12674	4444 N LANKERSHIM BLVD #101-103	91602	4	165B173   162	2423005011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	ADDRESS	34.15169	-118.36642	TENANT IMPROVEMENT OF (E) RESTAURANT AND CAFE SHOP: COMBINE BOTH TENANT SPACES TO FORM A  LARGE RESTAURANT,   ( UNIT # 101/102 & 103)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9632	19041-10000-12688	959 N SEWARD ST Ste103+201	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM			PC Info Complete	04/30/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	Full PC Pwr and energy for TI on officess Suite #103 and #201. existing service. area scope 45000SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9633	19041-20000-34460	10975 W BLUFFSIDE DR	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	09/02/2022 12:00:00 AM	ADDRESS	34.14171	-118.36918	PV2 BUILDING #1 (N) 18.4 KW AC/20.52 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (57) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9634	16041-10000-32830	1722 E 16TH ST	90021	14	120A213   207	5167002033	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.02315	-118.24168	PC FOR POWER AND ENERGY. NEW SERVICE 800A, COMMERCIAL BUILDING. FOOD PREPARATION. TOTAL AREA 8895 SQ FT. OUTDOOR LIGHTING HAS TO BE VERIFIED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9635	14041-10000-02275	904 W 28TH ST	90007	9	121-5A201  60	5123004403	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.02829	-118.28259	TENANT IMPROVEMENT AT THE ALPHA EPSILON PI FRATERNITY HOUSEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9636	17041-10004-17169	3763 S WALL ST	90011	9	117A205   431	5121023003	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	Apartment			01/29/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	34.01319	-118.27108	PC FOR REVISION TO APPROVED SET. CHANGES INCLUDE RELOCATING MODULES ON THE ROOF-LAYOUT PER INSPECTION REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9637	09041-10001-16003	11633 W SAN VICENTE BLVD	90049	11	132B145   475	4401019013	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM			PC Approved	11/04/2010 12:00:00 AM	ADDRESS	34.05413	-118.46325	DELTA 2 CHANGES TO APPROVES PLANS.   TI - existing building - New restaurant (office -> restaurant) - this is an area of assembly - Permit is for new panels, new ckts, new equipment, and new lighting to an existing core/shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9638	17041-10000-12354	13287 N RALSTON AVE	91342	7	225B141   172	2501002027	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Approved	05/19/2017 12:00:00 AM	ADDRESS	34.31289	-118.47324	Title 24 plan check.  Install two new cold storage units with new hallway lighting and emergency lighting in surrounding areas.  Total area = 4,365 sq. ft.     Building permit #17016-10000-09525	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9639	18041-20000-32273	3070 W LOS FELIZ BLVD	90039	13	157-5A207 257	5435017019	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.12455	-118.26614	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from bakery/cafe to banquet hall. Work includes a total lighting area of 12,560 sq. ft.Note: Building permit has been issued under 17016-20000-09853. Occupant load is 280.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9640	13041-10000-12133	14532 W HART ST	91405	6	183B149   421	2219026006	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			05/09/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.19736	-118.44995	New fire alarm system in 2-story 6 unit apartment bldg.  2 control panels and 29 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9641	17041-20000-24796	506 N STANLEY AVE	90036	5	141B177  1112	5526028014	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.08055	-118.35622	pv1install roof mounted pv system sized 4.4kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9642	15041-20001-12789	10351 W SANTA MONICA BLVD # 220	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	PIN	34.0585564	-118.42324002	Plan check for Title 24 only for office T.I. Total area: 2498 sq ft.{{{{{T I Project}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9643	10041-10000-15692	11833 W DARLINGTON AVE 1-11	90049	11	129B145   370	4265017035	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.05073	-118.46683	NEW FIRE ALARM SYSTEM. PLAN CHECK FOR POWER. ( 400$ INVESTIGATION FEE IS FOR FIRE SPRINKLER WORK.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9644	16041-10002-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.04771	-118.46271	PC to changes to approved set. Changes include shifting of receptacle and lighting loads (No new net branch circuits added). Increase in area in T24 calculations of 3794 sqft. All changes clouded delta 4 on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9645	15041-10003-00256	1060 S HOPE ST	90015	14	127-5A207 254	5139008010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.04228	-118.26281	Change to approved set by reconnecting feeder from panel P5A with a dual lug. note, all changes are under delta-RFI#29 only.(((PC for energy and power. T.I. Change of use from manufacture to office in an existing 6 story building.(levels 1 to 6). Total area 59261 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9646	15041-10000-16870	1200 E 5TH ST	90013	14	127-5A215 420	5163023001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.04159	-118.2359	CHANGE OF USE FROM OFFICE AND TOW YARD TO RESTAURANT WITH BUILD OUT FOR RESTAURANT INCLUDING NEW KITCHEN WITH HOODS AND TOILET ROOMS AND OUTDOOR UNROOFED  DINING. PLAN CHK IS FGOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9647	18041-10000-04267	8916 N CORBIN AVE	91324	12	195B117    40	2783025081	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Issued	02/06/2018 12:00:00 AM	ADDRESS	34.2326	-118.56211	PC for T24 only for replacement of outdoor metal halide fixture with new LED fixtures. Total area 29200sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9648	15041-10000-37392	1515 N VERMONT AVE FLR2,5,6,7-,8	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.09867	-118.29207	TI TO AN EXISTING COMMERCIAL BUILDING.  REPLACING EXISTING FIXTURES WITH LEDS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOATGE 2460.  SCOPE OF WORK TO BE PERFORMED IN FLOORS 2,5,6,7 AND 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9649	15041-20000-13938	9000 N RESEDA BLVD 103	91324	12	195B125   108	2769001022	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.23439	-118.53589	TI TO SUITE 103. NEW LIGHTING. PC FOR ENERGY ONLY. T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9650	17041-10000-11114	1023 N WILTON PL	90038	13	144B189   842	5536017036	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.08908	-118.31372	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  3850 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9651	18041-20000-44687	637 W WILSHIRE BLVD	90017	14	129A209    71	5144005031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.04869	-118.25681	T-24 only adding Ltg fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9652	15041-10000-16612	1840 S CENTURY PARK EAST 8TH FLR-RSTRM	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHING ONLY.  TOTAL SQUARE FOOTAGE 368.  SCOPE OF WORK IN THE 8TH FLOOR RESTROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9653	14041-10001-22912	2160 N LAKE SHORE AVE	90039	13	145-5A211 287	5420008002	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Apartment			08/22/2014 12:00:00 AM			Reviewed by Supervisor	09/10/2014 12:00:00 AM	ADDRESS	34.0924	-118.25255	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.75 ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(15) MODULES: CANADIAN SOLAR CS6-250PX(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9654	12041-10000-14807	1100 S CROCKER ST	90021	14	124-5A211 313	5132010059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	ADDRESS	34.03368	-118.25103	Change to lights, receptacles, A/C, and new panel for an existing warehouse with office building.  Load is less than 400A per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under INPSECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9655	19041-20000-30946	11150 W OLYMPIC BLVD STE 1120	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM			PC Info Complete	08/08/2019 12:00:00 AM	ADDRESS	34.03956	-118.43857	Plan check for Title 24 Energy only in existing office Tenant Improvement. Total area: 1826 sq ft. B#19016-40000-23443	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9656	15041-10001-14005	17810 W SIMONDS ST	91344	12	210B129    29	2711017014	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM			PC Approved	06/17/2015 12:00:00 AM	ADDRESS	34.27623	-118.5221	Expedited rses plan check per applicant request.<<PV1, Install 10 kW DC roof-mounted solar array, interconnect with service panel.  2 new 200 amp subpanel. 40 micro inverter: trina  solar tsm-250pa05.05 250 W.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9657	19041-30000-27265	5254 N DENNY AVE	91601	2	171B177   406	2416025001	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	01/25/2021 12:00:00 AM	ADDRESS	34.16646	-118.36414	INSTALL (58) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL IN 3 STORY APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9658	15041-20000-07108	1207 E ROBIDOUX ST	90744	15	033B209   156	7425017003	[Q]R2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	33.78851	-118.24832	Plan check for a PV1 roof-mounted system. System size is 3.8 kWac and consists of (12) units and (1) inverter. Standard plan is NOT being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9659	15041-10000-01485	6057 W HAROLD WAY	90028	13	147A189    11	5545008028	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.099	-118.32082	Plan check for a PV1 roof-mounted PV system. System consists of (38) modules and (2) inverters. System size is 7.8 kWac. Permit was not pulled online because of clearance issues.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9660	10041-10000-04198	11150 W SANTA MONICA BLVD # 100	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	04/16/2010 12:00:00 AM		Permit Finaled	06/07/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	CHANGING TWO TENANAT SPACES TO ONE TENANT SPACE -TENANT IMPROVEMENT IN RESTAURANT and  PARTIAL CHANGE OF USE FROM OFFICE TO CAFE & BAKERY PLAN CHK FEE WAS DETERMINED BY SUBMITTOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9661	14041-10000-07985	7301 W WORLD WAY WEST TBIT L4 &-L5	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	PIN	33.94386821	-118.41794839	TENANT IMPROVEMENT AT THE TBITEC OFFICES/CONFERENCE ROOMS; TERMINAL CONFERENCE OFFICES AND ANA AND PACIFIC AVIATION LEVEL 5 NORTHPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9662	13041-20000-23895	1616 N LA BREA AVE	90028	13	147B181   377	5548012046	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			09/03/2013 12:00:00 AM			Reviewed by Supervisor	10/16/2013 12:00:00 AM	ADDRESS	34.1002	-118.34456	New 56-unit, 4 sotry mixed-use building.  Power and energy.  A variance will be filed to separate the fire alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9663	19041-10000-05753	1965 S SAN PEDRO ST	90011	9	121-5A209 250	5127004023	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.02605	-118.25869	REMOVE OUTDOOR HID FIXTURE AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9664	19041-10001-00501	1925 S CENTURY PARK EAST 5th & 6th-Floors	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	pc for revision of an approved set. delta 1 changes. adding a new panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9665	15041-10001-05479	3901 W 6TH ST	90020	10	135B193   861	5503019010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.06364	-118.30808	12-22-15CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE LIGHTING LAY OUT AND FIXTURE TYPE. (((CHANGE USE OF EXIST RETAIL SPACE TO RESTAURANT USE AND COMBINE WITH ADJACENT EXIST RESTAURANT SPACE TO CREATE A LARGER RESTAURANT USE.  (N) OUTDOOR DINING.  PLAN CHECK FOR POWER AND ENERGY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9666	15041-10000-25089	12121 W BLUFF CREEK DR 2ND FLR	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Issued	11/02/2015 12:00:00 AM	ADDRESS	33.97874	-118.40463	TI TO AN EXISTING COMMERCIAL BUILDING 5 STORIES.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD >400 AMPS.  PLAN CHECK FOR POWER AND ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 30000. SCOPE OF WORK TO BE PERFORMED IN THE SECOND FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9667	14041-10000-03879	550 S HOPE ST FLOORS 11,-12,14,15	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.04989	-118.25574	Interior tenant improvement to floors 11, 12, 14, and 15 for (E) commercial highrise office building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9668	15041-10000-42601	3760 S CENTINELA AVE	90066	11	114B153  1222	4248032038	P-1, P-1VL, [Q]C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.0047	-118.43412	NEW LIGHTING FOR CANDY SHOP. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9669	16041-10000-40604	15001 W SUNBURST ST	91343	6	195B149    42	2651017011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.23453	-118.45864	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(12)MODULES-AXITEC AXIPOWER AC-265P/156-60S(1)INVERTER-FRONIUS PRIMO 6.0KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9670	10041-10000-05511	440 S VERMONT AVE	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	04/19/2010 12:00:00 AM		Permit Finaled	12/07/2010 12:00:00 AM	ADDRESS	34.0659	-118.29143	New methane mititgation system for existing and new commercial buildings.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9671	14041-10000-25717	7554 W LOLINA LANE	90046	4	156B177   266	5570010041	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			Reviewed by Supervisor	10/07/2014 12:00:00 AM	ADDRESS	34.12432	-118.36112	PV1, INSTALL 9.945 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(39) MODULES: KYOCERA KD255GX-LFB3(1) INVERTERS: FRONIUS IG PLUS A 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9672	16041-10000-14393	17963 RIDGEWAY ROAD	91344	12	216B129   231	2601018062	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	PIN	34.28692451	-118.52526248	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SYSTEM SIZE IS 9.0KW. (28)MODULES-SUNPOWER SPR-327NE-WHT-D(2)INVERTERS-- 1 SMA AMERICA SB6000TL-US-22 AND 1 SMA AMERCIA SB3000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9673	12041-10000-24147	810 S SPRING ST BSMNT	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.04268	-118.25375	REMODELING OF STAIRWAY AND RESTROOM IN BASEMENT LEVEL OF HIGH RISE BLDGPLAN CHK IS FOR TITLE 24. PERMIT FOR LIGHTING, RECEPTACLES, AND SWITCHES ON EXISTING CIRCUIITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9674	17041-20000-45781	12011 W WILSHIRE BLVD	90025	11	129B145  1047	4265014105	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Issued	01/04/2018 12:00:00 AM	ADDRESS	34.04567	-118.46582	Plan check for energy only. TI to (E) commercial retail building. New lighting - 1,908sqft. Building permit application #17016-20000-29031.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9675	14041-20000-12166	1620 W 237TH ST 1-10	90710	15	042B193   528	7439007029	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Apartment			05/07/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	33.8103	-118.30766	New 3-story 10-town home apartment building.  Units 1-10 typical per applicant.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9676	13041-10001-33040	7700 N FARMDALE AVE	91605	6	189B169   962	2316006012	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.21045	-118.38109	Expedited RSES plan check pr applicant request.[[][][]]PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE5000A-US. (23) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9677	13041-10001-09317	4030 S WESTERN AVE	90062	8	114B193   331	5021008030	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Info Complete	10/22/2013 12:00:00 AM	ADDRESS	34.01061	-118.30872	FULL PLAN CHECK POWER AND ENERGY FOR EXISTING SPACE (RALPHS) TO BE SUBDIVIDED FOR THREE NEW TENANTS. 600A SERVICE. 25543 sqrft     ((((((( Changes made to previously approved set. moved roof tops  , loas , panels ETC )))))))tHIS PLAN CHECK IS FOR DELTA 3 ONLY.  THIS IS PLAN CHECK ONLY PERMIT IS UNDER 13041-10000-09317	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9678	17041-10001-40878	18717 W HILLSBORO ROAD	91326	12	207B121   488	2728030018	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM			PC Approved	11/18/2017 12:00:00 AM	ADDRESS	34.2636	-118.54042	EXPEDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 14.74 KWDC / 12.3KWACSCOPE INCLUDES 44 MODULES WITH MICROINVERTERS WITH NEW LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9679	12041-10000-30295	6235 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	34.18398	-118.60617	CHANGE OF USE FROM A FURNITURE STORE TO CITI BANK WITH 1,111 SQ FT.  STORAGE SPACE AT BACK OF THE SPACE.  WORK INCLUDING INTERIOR DEMO & TI;  NEW CONCRETE VAULT;	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9680	18041-10000-01286	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.10311	-118.31242	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS FOR AN ENTRY LOBBY AND TRELLIS. TOTAL AFFECTED AREA IS 465 SQ. FT.   B#17014-10000-01500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9681	16041-10000-45030	1945 S FIGUEROA ST	90007	9	124-5A205 271	5126003024	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			Reviewed by Supervisor	01/23/2017 12:00:00 AM	ADDRESS	34.03334	-118.2731	PC for power and energy for new 5 story building for car dealership with 65,369sqft . Installing new 1600 A 480/277 V service. Functional areas include showroom, car service area, office and 4 upper levels of parking. Construction in methane zone with  no subterreanean parking.  16010-10000-06089**PROPOSED NEW CONSTRUCTION OF A FIVE-STORY BUILDING WITH ROOFTOP PARKING FOR AUTO SHOWROOM, SERVICE, PARTS STORAGE, AND PARKING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9682	13041-20000-07058	9112 N O'MELVENY AVE PV-1	91352	6	195B165    32	2629016007	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Expired	04/30/2015 12:00:00 AM	ADDRESS	34.23471	-118.40209	PV-1. 8.085 kW DC, one 7.5kW inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9683	10041-10000-25861	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	11/15/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	INSTALLATION OF 711KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF THE TOPANGA CANYON MALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9684	19041-10000-51312	6040 W SUNSET BLVD 6th floor	90028	13	147A189   228	5545013403	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			Corrections Issued	12/12/2019 12:00:00 AM	ADDRESS	34.0978	-118.32068	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 12906 SFQT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9685	15041-10001-12261	200 WORLD WAY SPACE 239	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM			PC Info Complete	06/23/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	CHANGES TO APPROVE SET, NOTE CHANGES DELTA 4. CHANGED LIGHTING FIXTURE AND ADDED 1 CIRCUIT. (((TI FOR TITLE 24, RETAIL SPACE TO REMAIN. PC FOR ENERGY ONLY. TOTAL SQ. FT. 1084. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9686	14041-10000-28262	12300 W WILSHIRE BLVD	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.04245	-118.46922	Title 24 plan check only.  Total area = 6,340 sq. ft.T.I. to existing commercial space.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9687	17041-20000-14319	624 W 190TH ST	90248	15	060B201    98	6121022903	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		5435.01	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Closed	11/17/2017 12:00:00 AM	ADDRESS	33.86082	-118.28564	Plan check for the installation of (1) temporary generator for existing pumps at a Public Works pumping plant. Temp generator will be used while the previously permitted back-up generator and ATS are being installed. Scope of permit for a (1) day temporary installation.Note: Permit for the permanent back-up generator and ATS has been pulled under 15041-10000-24913	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9688	15041-10000-10618	100 UNIVERSAL CITY PZ 24TH FL	0	4	162B177	2424044015	C2-1, PB-1					1437.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM				REMODELING OFFICE SPACE IN BLDG 1440-24PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9689	18041-20000-43570	4401 W SUNSET BLVD SMP	90027	4	147A201   109	5542009029	M1-1, [Q]C2-1	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.09708	-118.28526	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR INDOOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9690	18041-10000-27367	8631 W 3RD ST 445E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.07373	-118.38036	T-24, PC FOR TENANT IMPROVEMENT IN A MEDICAL  HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW CIRCUITS, RECEPTACLES AND LIGHTING IN PRIVATE OFFICES.  TOTAL SQ. FT. 384.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9691	19041-30001-32078	19191 S VERMONT AVE SUITE 1000	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE REVISION OF LIGHTING AND T-24 FORMS. PC ONLY_____________________________________________________________________________Plan check for Title 24 only in existing high rise building Tenant Improvement office building. Total area: 17,585 sq ft. B#19016-10000-25569	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9692	17041-20000-20268	19540 W TUBA ST	91324	12	204B117   242	2726009027	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.2565	-118.55967	pv1install roof mounted pv system sized 9.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9693	13041-10000-15400	830 S FLOWER ST #100	90017	14	129A209   267	5144020***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.04641	-118.26064	TENANT IMPROVEMENT FOR THE EXISTING MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9694	14041-10000-29992	5929 W SUNSET BLVD GROUND FLO	90028	13	147A191    60	5545009031	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			Verifications in Progress	12/16/2014 12:00:00 AM	ADDRESS	34.09821	-118.31893	FIRST TIME TENANT NEW STARBUCKS. 1542 SQ FT. HIGH RISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9695	16041-20000-17528	28138 S WESTERN AVE #10	90732	15	024B193   622	7442030207	P-1XL, [Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.76355	-118.31039	Plan check for power and energy Dental Medical Office T.I. in existing space. Total area: 2,164 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9696	16041-20000-10409	10949 W LONGFORD ST	91342	7	213B173   297	2529025018	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.27845	-118.36977	PV1.  Installation of 7.6 kW roof-mounted PV system.  Central inverter standard plan.  (18) modules with (1) 7600 W central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9697	11041-20000-07728	10820 N ZELZAH AVE	91344	12	207B129   193	2712021026	[Q]CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	04/28/2011 12:00:00 AM		Issued	04/28/2011 12:00:00 AM	ADDRESS	34.26641	-118.52316	NEW SERVICE UPGRADE FROM 400A TO 600A.  NEW SERVICE WILL BE RELOCTED FROM INSIDE THE BUILDING TO OUTSIDE THE BUILDING.  ALSO REPLACEMENT OF AN EXISTING PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9698	16041-20000-34035	12355 W LANDALE ST	91604	2	165B165    54	2364014053	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.15226	-118.40273	PV1.  Install 7.6 kW rated PV system.  (29) modules with (1) 7.6 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9699	10041-20000-23347	11611 W SAN VICENTE BLVD 8th Floor	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	T.I. to existing high rise building room numbers #800 - #824 as shown on plans.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9700	13041-10000-31163	1900 S AVENUE OF THE STARS SUITE 650	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.05979	-118.41671	PLAN CHECK FOR T24 ENERGY ONLY. RELOCATIONG OF LIGHTING FIXTURES. HIGH RISE. 6TH FLOOR SUITE 650. 4794 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9701	18041-20000-43309	13630 W BASSETT ST	91405	2	183B157   764	2328012006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.19567	-118.43003	pv1install roof mounted pv system sized 9.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9702	12041-20000-27476	8743 W HOLLYWOOD HILLS ROAD	90046	5	153B169   644	5564012026	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.11339	-118.38579	Photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9703	12041-20000-08465	7224 W HILLSIDE AVE 1-39	90046	4	150B181   604	5572031016	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	Apartment			04/13/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Expired	05/08/2014 12:00:00 AM	ADDRESS	34.10443	-118.34725	Installation of new fire alarm panel and one new device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9704	17041-10000-18810	13186 W TONOPAH ST	91331	6	192B157    49	2627020004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.22675	-118.41982	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9705	17041-30000-23692	853 S LUCERNE AVE	90005	4	132B189  1263	5090020077	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.0589	-118.32596	Plan check for a fire alarm system. Fire alarm system consists of (1) FACP, (1) annunciator, and (63) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9706	15041-10000-36772	2706-2708 E CESAR E CHAVEZ AVE	90033	14	127-5A225  74	5180017002	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2042.00	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	34.04493	-118.20391	1345 sq. ft. restaurant TI.  Plan check for energy.Refer code enforcement case #404180investigation fee collected under this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9707	19041-10001-06939	3931 S LYCEUM AVE	90066	11	111B153  1286	4236023013	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			Reviewed by Supervisor	03/04/2019 12:00:00 AM	ADDRESS	33.99621	-118.4399	EXPEDITE PER APPLICANT REQUESTPC for ROOF MOUNTED PV ON SFD.System includes (21) modules (REC solarr: RETP2), (21) 320 solar edge optimizers, (1) LG chem 5kw battery, (1) solar edge 7600 inverter. (1) load panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9708	11041-10000-19651	7963 N VAN NUYS BLVD	91402	6	189B149   310	2210019004	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.21603	-118.44897	SERVICE UPGRADE TO 800 AMP & TI IN AN EXISTING COMMERCIAL AREA. INSTALL NEW PANELS & CIRCUITS. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9709	18041-20003-22593	10650 N DE SOTO AVE	91311	12	207B109   345	2706011001	(T)(Q)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.26388	-118.58835	12/12/19CHANGES TO APPROVED SET DELTA 1 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9710	11041-10000-00836	448 S HILL ST 2nd fl	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	02/16/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.04896	-118.25139	TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING.  NEW PANEL BOARD AND BRANCH CIRCUITS, PLAN CHECK FOR POWER AND ENERGY TITLE 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9711	11041-20000-04178	300 S GRAND AVE #300	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	04/15/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	PIN	34.05243427	-118.25124731	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR INTERIOR T.I. ON #300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9712	17041-20003-41503	1812 S ROXBURY DR	90035	5	129B165   711	4307013027	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.04821	-118.40115	Changes to approved set of plans, changes noted under delta 1 - Changes include conductor resizing, and increasing disconnect from 60A to 100A.  Original permitChanges to approved set of plans.  Change of interconnection point to (E) 200 A subpanel within laundry room.  Plan check fee $0.00 by state senate bill no. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9713	17041-20002-37249	10303 N NORRIS AVE	91331	7	204B165   123	2537005014	M1-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.25696	-118.40297	changes to an approved set of plans.  changes noted delta 2.  changes to revise plans per existing field conditions.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9714	19041-10000-34295	766-770 E WASHINGTON BLVD 1st Flr	90021	9	121-5A209 211	5131007001	C2-2D-O-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			Reviewed by Supervisor	09/11/2019 12:00:00 AM	ADDRESS	34.02652	-118.25545	New Nursery/Agricultural operation on portion of the first floor. There are two existing services: 120/240, 1Ph & 3Ph, 400 Amp each. All regular and emergency lights in common areas for general lighting are existing to remain. ***Building Permit HAS NOT been issued yet***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9715	14041-10000-25041	1945 S OVERLAND AVE 1-8	90025	5	129B157   764	4321010039	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.04901	-118.43105	Fire alarm system for 8 units, 4-story building. total 46 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9716	17041-10001-18839	2920 S SPAULDING AVE	90016	10	120B173   102	5048014030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM			PC Approved	07/05/2017 12:00:00 AM	ADDRESS	34.02855	-118.36993	Changes to approved set.  New module layout on roof and change of inverter to Solaredge SE5000A-US.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9717	16041-10001-09086	900 W WILSHIRE BLVD 69th floor	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM			PC Approved	09/28/2016 12:00:00 AM	ADDRESS	34.05001	-118.25963	09/28/2016 Changes to an approved set of plans. All changes are made under delta 3. Changes include removing split bus on panels, relocating circuits, changing lighting type and layout, and adding new receptacles.  Note: Permit is pulled under PCIS#16041-10000-09086(((((First time tenant Full PC to a multi used high rise bulding. Scope of work is on the 69th floor with total area of 13,110 SQ feet. )))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9718	16041-10000-06447	12573 W TERRA BELLA ST	91331	7	207B161    95	2536013018	RS-1	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.26624	-118.40714	PV1 sfd total system size 5000W AC. Total of 20 modules. using microinverter system with enphase m250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9719	16041-10000-22155	1038 W VENICE BLVD	90015	1	126A203    36	5135024035	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	PIN	34.04105737	-118.2787675	PC for T-24 only. Remove 150W fixtures and replace with new 53W LED fixtures. Total area: 19,194 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9720	12041-10002-02932	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	33.97704	-118.40702	"REVISED PERMITTED SET OF PLANS-ADDED A SUBPANEL TO WHICH IS ADDED 4 CKTS FOR THE ELECTRIC CAR CHARGERS((((((((((((PLAN CHECK POWER ANND ENERGY FOR INTERIOR TENANT IMPROVEMENTS ""YOU TUBE"" BROADCAST STUDIO AND OFFICE.  SITE IN METHANE ZONE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9721	18041-10000-14498	11044 W WEDDINGTON ST	91601	2	171B173   324	2350014018	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.1669	-118.37185	PC FOR POWER AND ENERGY FOR CHANGE OF USE WAREHOUSE TO DANCE STUDIO. TOTAL CONNECTED LOAD >400A. SCOPE INCLUDES NEW PANELS, CIRCUITS, LIGHTS AND RECEPTICALS. TOTAL AFFECTED AREA IS 8967 SQ.FT. B#18016-10000-06264	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9722	14041-20001-08544	8448 N VARIEL AVE	91304	3	192B105   328	2779045030	R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	ADDRESS	34.22361	-118.59275	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9723	13041-10001-30812	2227 S MALCOLM AVE	90064	5	126B157   301	4320001044	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.04413	-118.42939	Expedited RSES plan check per applicant request. (((PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 18 modules Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9724	17041-20000-30661	9841 N AIRPORT BLVD 14th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Info Complete	08/28/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building( high rise).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9725	19041-10000-07769	5500 W JEFFERSON BLVD	90016	10	120B173  1730	5047015033	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.02557	-118.3665	FULL PLAN CHECK FOR A FIRST TIME TENANT IN AN OFFICE SPACE. PARTIAL SPACE OF THE FLOOR WAS PERMITTED UNDER A SEPERATE PERMIT. SCOPE INCLUDES 3 NEW PANELS, EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 7834 SQ.FTB#19016-10001-02605	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9726	17041-10000-11069	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Closed	09/01/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC FOR TITLE 24 FOR A TEMP BAGGAGE CLAIMS.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES .BLD APP #16010-10001-05575DEFERRED SUBMITTAL - SPRUNG STRUCTURE (structural only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9727	19041-20000-33336	129 S ROCKINGHAM AVE	90049	11	132B137   318	4406001020	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM			PC Info Complete	01/25/2021 12:00:00 AM	ADDRESS	34.05709	-118.4934	Install new 208/120v 3ph 4w service. Install new panels and equipments.Building permit number 19010-30000-01470	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9728	19041-10000-24464	633 W 5TH ST 68 th FLR	90071	14	130-5A209 230	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	T-24, PC FOR ENERGY ONLY. T.I OF AN EXISTING HIGH RISE BUILDING ON 68TH FLOOR OFFICE SPACE. TOTAL AFFECTED AREA 9108 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9729	19041-10000-38869	5500 W 98TH ST QTA	90045	11	093B173   581	4128022906	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	07/13/2020 12:00:00 AM		Permit Finaled	02/01/2024 12:00:00 AM	ADDRESS	33.94764	-118.37749	LAX LAMP CONRAC QTA 3 STORY AUTO SERVICING AND REPAIR BUILDING. MED VOLTAGE. POWER & ENERGY PLAN CHECK. AFFECTED AREA: 908,530 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9730	12041-10000-30911	601 S WESTERN AVE	90005	10	135B193   894	5503031007	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			12/26/2012 12:00:00 AM	03/12/2013 12:00:00 AM		Issued	03/12/2013 12:00:00 AM	ADDRESS	34.06328	-118.30927	"this new application number is for a resubmittal for lost plans. this is a copy of previuos application ending in 04628. no new branch circuits for the units.New service, main switchboard and panels for an existing mixed-use comercial/residential building on the corner of 6th St and Western Ave.   TENANT SPACES ARE MARKED AS ""FUTURE"", LOADS ARE NOT KNOWN AND WILL REQUIRE FULL PLAN CHECK WHEN TENANT DOES IMPROVEMENTS.Main switchboard is at address 601 S. Western Ave #101.  Sub-panels are at address 601, 603, 605 Western Ave, and 3956, 3956 1/2, 3958, 3960, 3962, W. 6th St. and 3950 W. 6th St Suites 301-414."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9731	11041-20000-09555	8629-8633 N WOODLEY AVE	91343	12	195B137   956	2689024022	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/11/2011 12:00:00 AM	ADDRESS	34.22748	-118.48551	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY LIGHTING ) ONLY FOR EXISTING RETAIL SPACE DIVIDE INTO 5 (N) RETAIL SPACES. (8629-8633)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9732	13041-10000-30937	5420 W WILSHIRE BLVD 1ST FLOOR	90036	4	132B181    15	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.06205	-118.34684	PC for power and energy for Bank of America moving into vacant tenant space on ground floor of commercial highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9733	19041-10000-43429	1652 N ALEXANDRIA AVE	90027	4	147B197   305	5543005006	C2-1D	Central	Hollywood			1912.01	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.10136	-118.29824	REMOVE EXTERIOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES AND REPLACE FLOURESCENT TROFFERS WITH NEW LED RETROFIT KITS-T/24 ONLY (INDOOR & OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9734	18041-10000-03052	12701 W VAN NUYS BLVD	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Closed	02/13/2018 12:00:00 AM	ADDRESS	34.27621	-118.41056	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. PLAN CHECK T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9735	14041-20000-28940	9687 N SUNLAND BLVD	91040	7	201B177   267	2543030023	C1-1VL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM			PC Approved	10/20/2014 12:00:00 AM	ADDRESS	34.2472	-118.35686	T.I. to existing building.  Install general and emergency lighting.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9736	10041-10000-24663	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	NEW 7 STORY MEDICAL OFFICE BUILDING. CORE & SHELL ONLY. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9737	12041-20001-12387	215 W 9TH ST 215	90014	14	127-5A209 313	5144017***	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	PIN	34.04277246	-118.25624184	energy plan check retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9738	14041-20000-32903	749 S SAN JULIAN ST	90014	14	126A211   456	5145005019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	PIN	34.04006359	-118.24900872	PC FOR NEW DISTRIBUTION PANEL. RELOCATE LOADS FROM EXISTING SERVICE TO NEW DISTRIBUTION PANEL TO MAKE ROOM FOR NEW PV SYSTEM. CONTRACTOR TO BLOCK OFF FUTURE CONNECTIONS TO MAIN SERVICE. NEW DP PANEL TO BE RATED 22K MINIMUM TO HANDLE LET THRU CURRENT, MOTOR CONTRIBUTION, AND PV CONTRIBUTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9739	10041-20000-01556	10250 W SANTA MONICA BLVD B6	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM	02/26/2010 12:00:00 AM		Permit Finaled	04/27/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	"Delta 4, 5,& 6 Revisions to approved plans with PCIS #09041-20000-09114 (Tenant improvement - retail store, ""H&M,"" in mall. (PHASE 2 OF 2)). Engineer changed and a wall was moved."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9740	19041-20000-25476	18853 W KILLOCH WAY	91326	12	216B121   131	2820014009	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.29152	-118.54409	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 5.28 KW DC/4.856 KW AC.SCOPE OF WORK INCLUDES (16) PANASONIC PV MODULES WITH ENPHASE MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9741	14041-20000-12624	12056 N GERALD AVE	91344	12	216B137   164	2609029051	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.28967	-118.49194	PV1. 6KW roof-mounted system with (24) Trina Solar #TSM-250PA05.18 modules,(1) Solaredge # SE6000A-US inverter, and (1) SolarEdge Power Optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9742	19041-10002-36511	233 S ANITA AVE	90049	11	129B141    57	4405030004	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.05351	-118.48225	"DELTA ""1"" Changes to approved plans.<<<PV1, NEW ROOFTOP MPUNTED SYSTEM, SYSTEM SIZE IS 11.55 KWdc/11.2 KWac. SCOPE OF WORK IS 35 MODULES (PANASONIC VBHN330SA17E) WITH MICRO INVERTERS (ENPHASE IQ7X-96-2-US), LEADING TO A ENPHASE COMBINER BOX, LEADING TO A MAIN BREAKER DERATE (PERMIT  HAS BEEN PULLED FOR THE BREAKER DERATE).>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9743	12041-10000-30742	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Closed	04/16/2015 12:00:00 AM	PIN	34.12750533	-118.21285206	PLAN CHECK FOR FIRE ALARM WITH OVER 150 DEVICES.  INSTALLATION OF NEW INTIATING AND INDICATIN DEVICES. OCCIDENTAL COLLEGE JOHNSON HALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9744	15041-20001-27966	6749 N FALLBROOK AVE #915	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	34.1925	-118.62407	"09-30-2015 Changes to approved set of plans. Changes include, down size panel ""LN"" to 400A and delta 2 only. [[[[[Plan check for core and shell power only in existing space 500A @ 480V transformer step down to 600A @208V.]]]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9745	11041-20000-21656	1025 E ADAMS BLVD	90011	9	118-5A209 348	5131026029	C2-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	12/06/2011 12:00:00 AM	ADDRESS	34.01916	-118.25542	NEW BAKERYENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9746	14041-10000-11511	10320 N TUJUNGA CANYON BLVD	91042	7	204B197   733	2565010058	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.25654	-118.29114	PV1 2.25KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(9)modules: {Canadian Solar {CS6P 250P}}])	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9747	10041-20000-25626	6500 W WILSHIRE BLVD 23RD FL	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	03/04/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR 23RD FL OFFICE TI. EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9748	10041-10001-14422	6201 W HOLLYWOOD BLVD	90028		148-5A189  54	5546031001	[T][Q]C4-2D-SN		Hollywood	Hollywood United			Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM			PC Approved	03/10/2011 12:00:00 AM	ADDRESS	34.1018	-118.32461	REVISIONS TO SHEETS EN603'EN605;EN606;EN607 DECREASED THE AL FEEDERS SIZES TO DIMINISH THE % VOLTAGE  DROPS AND PROPORTIONALLY DECREASED THE ELECTRICAL EQUIPMENT GROUNDING CONDUCTORS- )))))))))))))NEW MIXED USE (APARTMENT, RETAIL, OFFICE), 6 STORY BUILDING OVER 5 LEVELS OF BASEMENT GARAGE,  516 UNITS ( 11 TYPES ) OF APARTMENT AND 18 UNITS OF LIVE/ WORK.  Note: above description will be amended by Building section	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9749	14041-10000-23282	11901 S AINSWORTH ST	90044	15	084B197   392	6088020008	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	33.92491	-118.29031	Installation of roof mounted solar system.  System size = 6.6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9750	14041-20000-16368	19331 W BUSINESS CENTER DR 102	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.23118	-118.55466	Change of use from storage to vascular access medical clinic with critical care patient areas including lights, power and sub panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9751	17041-10000-26624	800 WORLD WAY TERM 8	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Info Complete	08/03/2017 12:00:00 AM	ADDRESS	33.94305	-118.39757	PC FOR OFFICE TI -Remodel existing office space FOR TITLE 24 ENERFY ONLY. TOTAL AFFECTED AREA 493 SQ.FT. SCOPE INCLUDES NEW PANEL, LIGHTS, RECEPTACLES AND CIRCUITS. b#17016-10000-18483	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9752	18041-20000-17798	11000 N NOBLE AVE	91345	7	210B145   362	2615011009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Issued	05/14/2018 12:00:00 AM	ADDRESS	34.26922	-118.45942	PV1.  Install 6.825 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (21) modules with 6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9753	17041-10000-44886	777 S FIGUEROA ST # 3775	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	ALTERATIONS IN EXISTING OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9754	15041-20001-28299	11105 S COMPTON AVE	90059	15	088-5A213 510	6070009034	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2015 12:00:00 AM			PC Approved	09/06/2015 12:00:00 AM	ADDRESS	33.93456	-118.24641	EXPEDITE PER APPLICANT REQUEST.((PV1. PC FOR A NEW ROOF MOUNTED PV SYSTEM INSTALLED ON TWO STORY HOUSE. TOTAL SYSTEM SIZE 3.06KW. SUBMITTAL PER APPLICANT REQUEST.(12) MODULES-HYUNDAI HEAVY INDUSTRIES HIS-M255RG(12) MICROINVERTERS-M215-60-2LL-S2X-IG INVERTERS))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9755	18041-10000-33673	12445 W MOUNTAINGATE DR	90049	11	150B137     1	4490024009	[Q]A1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/08/2021 12:00:00 AM	ADDRESS	34.1074	-118.48784	FULL PC FOR POWER AND ENERGY. ADDITION AND REMODEL OF EXISTING GOLF COURSE CLUBHOUSE BLDG AND EXPANSION. SCOPE INCLUDES THREE NEW PANELBOARDS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 11085 SQ. FT. B#18014-10000-05033	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9756	11041-10000-24382	1020 E LAKE ST BLDG 6-2	90291	11	111B145   517	4243003041	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.00194	-118.46034	Lincoln Place Apartment Building Project.  New 2-story apt. building with 7 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9757	17041-10000-15299	2221 E WASHINGTON BLVD Bldg C	90021	14	118-5A217  73	5167019041	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.01912	-118.23236	PC for energy only, Indoor Title 24. Removing HID fixutres and replacing them with new LED fixures. Area: 4,500 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9758	12041-10000-18228	140 N HIGHLAND AVE	90004	4	138B185   186	5513008008	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM			Reviewed by Supervisor	10/18/2012 12:00:00 AM	PIN	34.07485921	-118.33814476	NEW 3.12 KW PV SYSTEM USING MICRO INVERTERS ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9759	14041-10000-17031	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.03396	-118.24117	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CAFE DULCE . NEWLYCONNECTED LOAD <400 AMPS. 3280 SQFT, EMERGENCY LIGHITNG.  COMPLY W/ DEPT ORDER DATED 12/22/10. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. **INVESTIGATION FEE PAID THROUGH #12016-10000-16091**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9760	14041-10000-35238	9136 N DE SOTO AVE	91311	12	198B109   155	2748037023	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.23665	-118.58833	Plan check for Title 24 only. Project scope is to remoce HID fixtures and replace with new LED fixtures. Total lighting area = 4,668 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9761	17041-10001-34329	2911 W BEVERLY BLVD	90057	13	138A201   301	5156019030	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM			PC Approved	11/02/2017 12:00:00 AM	ADDRESS	34.07133	-118.28058	Fee expedite per applicantInstall new rooftop solar system on a multi tenant commercial building, 32.86 kW DC system.  (124) modules with (124) enphase microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9762	13041-10001-36244	7702 N SALE AVE	91304	12	189B097  1156	2013017009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.21031	-118.6184	Expedited RSES plan check per applicant request.{{PV1, Install 12.75 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 6000A-US. (51) Modules: Trina Solar TSM-250PA05.18.(51) Optimizers: Solaredge OP250-LVMC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9763	16041-10000-05912	5631 N FIGUEROA ST	90042	1	151-5A229 222	5468033021	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.10952	-118.19331	PC for energy only. Change of use from retail to restaurant. Ti remodel. Adding 4 new panels, total connected load is less than 400 Amps. Adding new ligthing and power. Total sqft = 2465. ***NOTE, INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT NUMBER: 15041-10000-42385.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9764	13041-10000-08855	870 S 5TH AVE	90005	4	132B189   900	5092014003	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2013 12:00:00 AM			Verifications in Progress	10/01/2013 12:00:00 AM	ADDRESS	34.05619	-118.3179	PV1 SINGLE FAMILY DWELLING. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTERS. SYSTEM SIZE: 9.43 kW. 41 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9765	15041-20000-41314	9757 N TELFAIR AVE	91331	7	201B161   691	2624014065	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.24657	-118.40827	PV1, roof mounted solar isntallation(16) SW 260 MONO(1) Fronius PRIMO 3.8-1 Submitted per Applicant	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9766	15041-10001-27102			11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	PIN	33.97921419	-118.41007299	PV2 ROOF MOUNTED. TOTAL SYSTEM SIZE 1.84 KW ON COMMERCIAL 4-STORY BUILDING (BUILDING 8 UNIT 22) UNIT ONE (8) MODULES: SUNPOWER MODULES SPR-230NE-BLK-D(1) INVERTER PVI3.0 OUTD-S-US-A (POWER ONE) 240VACZONING CLEARANCES FOR UNIT 1,2, AND 3 INCLUDED.EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9767	12041-10000-11867	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM	05/25/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.0754	-118.38272	Installation of two new branch circuits in lab. Relocation of less than 50% of lights. Plan check for medical requirements.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9768	14041-20000-06740	20044 W VENTURA BLVD	91364	3	174B113   598	2166043006	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.17103	-118.57007	PC FOR T24 ENERGY ONLY. TOTAL AREA 1200 SQ FT. SUBWAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9769	19041-20000-44192	7022 W ST ESTABAN ST	91042	7	201A201   214	2564017016	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Issued	10/29/2019 12:00:00 AM	ADDRESS	34.24621	-118.28428	PV1. INSTALL 3.78 KW DC PV SYSTEM WITH (12) MODULES/OPTIMIZERS AND (1) INVERTER(SE3800H) AND (1) TESLA STORAGE BATTERY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9770	14041-20001-04059	11747 N RICASOLI WAY	91326	12	216B109    82	2701077026	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.28609	-118.58475	Expedite Fee ONLY*****Roof mounted PV system with 6 KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9771	18041-20000-24755	9901 W WASHINGTON BLVD 1st&6th FL	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.02174	-118.39786	Plan check for Title 24 Energy only in existing space T.I. 1st Floor commom area and 6th Floor Patio. Total aera: 2455 sq ft.B#18016-30000-20933	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9772	13041-20000-31611	14207 W GAULT ST	91405	6	183B153   291	2217022078	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.19946	-118.44247	New 10.46kw rooftop photovoltaic system for an existing single family dwelling.  System is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9773	10041-10000-22453	425 S PALOS VERDES ST 5TH FL	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	02/27/2012 12:00:00 AM	ADDRESS	33.74102	-118.28156	ALTERATIONS ON THE 5TH FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9774	11041-20000-04268	1009 S ABBOT KINNEY BLVD	90291	11	109-5A143 413	4286012003	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM			PC Approved	03/08/2011 12:00:00 AM	ADDRESS	33.9923	-118.47239	Per applicant, plan check for energy only.  Install general/emergency lighting.Note: Permit is under 10041-30001-17375.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9775	12041-10000-29311	13455 W MAXELLA AVE #250	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	04/04/2013 12:00:00 AM		Issued	04/04/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT (SETTEBELLO RESTAURANT) #250 . FULLY SPRINKLERED SPACE. EXISTING MARKETPLACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9776	16041-10000-33195	2270 E 99TH PL 101-206	90002	15	093A217   271	6049019***	CM(UV), OS(UV), R3(UV), RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	33.94698	-118.23139	PC for power only for a New 3-story 10 unit apartment Block 3 Building B2 (BLDG 1 OF 8).  Scope includes a new 600A 120/208V 3 phase 4 wire service/distribution board. One set of plans is submitted for multiple apartment buildings. B#16041-20000-31401	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9777	13041-20000-31622	4235 N FULTON AVE	91423	4	165B157   697	2360011006	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.14771	-118.4227	NEW 30 UNIT APARTMENT BUILDING. FEES CALCULATED BY APPLICANT AND TO BE VERIFIED. FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9778	15041-10000-02099	1000 S HOPE ST	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.04346	-118.2617	installation of transformers and panelboards.permitted under original plan check application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9779	11041-20000-11570	13520 W PAXTON ST A-1	91331	7	210B157  1074	2535002015	M3-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	07/18/2011 12:00:00 AM	ADDRESS	34.27356	-118.42606	Plan check power and energy for first time tenant (A-1). Site in methane zone. Existing panel and RTU unit. No underground penetration.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9780	16041-10000-35627	1150 S OLIVE ST 16TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.03962	-118.26181	PC for energy only to the 16th floor of a high rise office building, corridors only. New lighting and power. Total sqft = 1720.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9781	19041-20000-05467	4355 N LEMP AVE	91604	2	165B169   435	2365020011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.14878	-118.38459	Plan check for Energy Storage System installed in to existing PV system, installed 2 Tesla Battery Power Wall 2.0(13.5kWh) 27KWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9782	15041-20001-07849	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.12774	-118.26247	Change to approved set. Plan check for Addition of 2  new hearing exam booths to Costco. No light is being add to the 2 new booth; light is part of the booth. {{{{{{PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COSTCO OPTOMETRY ROOMS. NOT A MEDICAL ( CONSULTATION ONLY) 615 SQFT.}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9783	16041-10000-05812	23416 S SIDLEE PL	90710	15	042B193   341	7438011003	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	33.81194	-118.30183	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 24 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9784	14041-10000-13390	7912 W JAYSEEL ST	91040	7	208-5A195 270	2556008108	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.26532	-118.30532	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM USING STANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9785	18041-10003-34502	10419 W DUNLEER DR	90064	5	123B161    22	4318021023	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM			PC Approved	11/07/2018 12:00:00 AM	ADDRESS	34.03702	-118.41235	CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES UNDER DELTA 2. CHANGES INCLUDE THE CHANGE OF BREAKER SIZE TO 15AMPS FOR THE MOITORING EQUIPMENT. PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9786	16041-20000-07535	12423 N GLADSTONE AVE #15	91342	7	219B161   251	2525018057	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.29571	-118.4121	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9787	15041-10000-31819	12011 W SHERMAN ROAD	91605	2	183B165    13	2317016015	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Expired	10/23/2017 12:00:00 AM	ADDRESS	34.20152	-118.39546	PC FOR ENERGY. REMOVE HID LLIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 20512 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9788	12041-10000-31142	14455 W VENTURA BLVD	91403	5	166-5A151 113	2265014011	C4-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	PIN	34.1511806	-118.44819	TI FOR 3 STORY OFFICE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9789	18041-20000-24992	12569 N BYRON AVE	91344	12	219B133   223	2608008004	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.29897	-118.51031	pv1install roof mounted pv system sized 11.4kw AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9790	16041-20000-41872	700 S FLOWER ST Ste 500	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Highrise commercial office TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9791	14041-10000-06843	6600 N TOPANGA CANYON BLVD # 2078	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLANCHECK FOR TITLE 24 ENERGY. TENANT IMPROVEMENT FOR BCBG IN TOPANGA MALL. SUITE 2708 . 3008 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9792	10041-20000-10187	6203 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	06/08/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.18321	-118.60617	AT & T remonelEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9793	19041-10000-05907	700 W 9TH ST	90015	14	129A207   333	5138017***	C2-4D-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	12/01/2020 12:00:00 AM	ADDRESS	34.04579	-118.2618	CHANGE OF USE FROM RETAIL (CORE AND SHELLL) TO RESTAURANT IN A 28-STORY MIXED USE (RESIDENTIAL AND COMMERCIAL BLDG). PLAN CHECK FOR POWER & ENERGY. BULDING PERMIT: 19014-10000-00059	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9794	18041-10000-07138	2335 N GRIFFIN AVE	90031	1	138A223   119	5204020007	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.07287	-118.21189	PC  FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 5.31 KWDC /5.0 KWACSCOPE INCLUDES 18 MODULES WITH OPTIMIZERS AND SINGLE CENTRAL INVETER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9795	17041-20001-26736	11000 N NOBLE AVE	91345	7	210B145   362	2615011009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.26922	-118.45942	expeditepv1install roof mounted pv system sized 5kw with (2) battery backup tesla powerwalls interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9796	13041-20000-19030	1130 S GRAMERCY DR PV-1	90019	10	129B193   793	5081029002	R1-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.04988	-118.31203	PV-1. Microinverter. 34 modules for 7310W AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9797	18041-10000-23086	977 N NORTH BROADWAY	90012	1	136-5A215 263	5414007022	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.06611	-118.23652	INSTALLATION OF A FIREALARM SYSTEM. 1 FACP, 6 RPS, 180 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9798	14041-10000-30889	1317 N ORANGE GROVE AVE	90046	4	144B177    21	5551027016	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.09504	-118.36053	PV1 with 5KW AC system including (1) Solaredge SE5000 inverter, (24) Rec260PE modules and P300 power optimizers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9799	19041-20000-15596	2927 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Closed	11/08/2021 12:00:00 AM	ADDRESS	34.1042	-118.24379	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9800	12041-20000-15236	1751 S WESTWOOD BLVD	90024	5	129B153   370	4324028047	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM			PC Info Complete	10/02/2012 12:00:00 AM	ADDRESS	34.05089	-118.43821	T.I. change use from retail to grocery store (Sprouts) in an existing building.  Relocate panel, add new branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9801	18041-10000-08173	3060 W OLYMPIC BLVD STE 120	90006	10	129B193   321	5080030044	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.05239	-118.30229	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO ADULT DAY CARE FACILITY. SCOPE INCLUDES NEW PANELS, NEW 45KVA TRANSFORMER, NEW CIRCUITS,  AND NEW LIGHTS. TOTAL AFFECTED AREA IS 7954 SQ. FT. B#18016-10000-13558	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9802	11041-10000-04587	1200 S CABRILLO AVE	90731	15	015B197  1440	7454022005	R4-1	Harbor	San Pedro	Central San Pedro	YES	2969.00	Electrical	Electrical	Public Safety Only			03/09/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	33.73315	-118.29441	New fire warning  system  at Boys & Girls Club in San Pedro	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9803	14041-10000-04654	2029 S CENTURY PARK EAST #  2500	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI FOR SUITE 2500  25TH FLOOR . HIGH RISE. TITLE 24 NO EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9804	16041-20000-40733	14043 W AUBREY ROAD	90210	4	159B153    17	2272033060	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Issued	01/17/2017 12:00:00 AM	ADDRESS	34.13567	-118.44026	permit fee $0.00 by state senate bill no. 1222Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9805	16041-20001-11387	8301 N CANOGA AVE	91304	3	192B105   594	2779036013	C2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	34.22025	-118.59775	7.12.2017 - Plan check for modifications to approved set. Indoor floor layout rearranged - update lighting plan power plan, and indoor T24 documents - changes clouded. Changing service from 400A 480/277V to 800A 208/120V - Recheck entire SLD. =======Plan check for power and energy. Project site is a new gas retail/market building and gas station. DWP service is existing (gas station is replacing car wash). Total lighting area = 24,086 sq. ft.Note: Building permit has been created under 16010-20000-00069	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9806	18041-10000-01309	17331 W TRAMONTO DR	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 1 (CAMPUS STYLE)SCOPE INCLUDES 102 DEVICES AND 2 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE.B#16010-10001-00075BUILDING 1  (PLAN A1/ A1R)  8 UNITS AND 4 STORY  TYPE IIA  APARTMENT  BUILDING WITH  TYPE IB GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9807	15041-20000-06691	7011 W GREELEY ST	91042	7	202-5A201 327	2568015020	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.24891	-118.28361	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  20 modules with miroinverters on 1 branch circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9808	18041-20000-37991	14062 N BALBOA BLVD	91342	7	228B137   186	2603007027	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.32065	-118.4882	Plan check for a PV2 roof-mounted PV system. System size is 321 kWdc/279.69 kWac-CEC and consists of (9) inverters, (892) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9809	12041-10001-01069	1925 S SAWTELLE BLVD	90025	11	126B153   576	4261030045	C2-1VL, R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.04166	-118.44456	FIRE ALARM / LIFE SAFETY, SPRINKLER MONITORING, AND ELEVATOR RECALL.  This application is for plan check only, permit is on main application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9810	18041-20000-18913	6080 W CENTER DR 5th Floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	33.97713	-118.39172	Common area improvements in (E) commercial highrise office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9811	19041-10000-46372	22507 W HAYNES ST	91307	12	180B101   421	2038033021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.18981	-118.61707	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 19 (CERTAINTEED CT315M11-02 ) MODULES, 19 (SOLAREDGE P320 ) OPTIMIZERS, 1 (SE5000H-US) CENTRAL INVERTER, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL . SYSTEM SIZE IS 6.08KW DC & 5.00KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9812	13041-20000-11726	12000 W IDAHO AVE	90025	11	126B145   893	4259003006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			05/07/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.03918	-118.46049	NEW FOUR STORY 34-UNIT APARTMENT BUILDING. 1600 A SERIVCE. FEES CALCULATED BY APPLICANT, FEES TO BE RECALCULATED BY PLAN CHECKER. FIRE ALARM WILL BE PULLED BY CONTRACTOR AND FIRE ALARM VARIANCE WAS FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9813	13041-10000-30823	10840 W WILSHIRE BLVD	90024	5	132B153   338	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.05924	-118.44131	"NEW FIRE ALARM SYSTEM FOR A PROPOSED 4-STORY COMMERCIAL BUILDING ( ""IPIC THEATERS""). FULLY SPRINKLERED SYSTEM, WITH BASEMENT LEVEL AND ROOF. TOTAL OF 192 DEVICES, 2 PANELS. BUILDING AREA IS APPROXIMATELY 157,523 SQ FT PER FLOOR. BUILDING OCCUPANCY : A.1 THEATERS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9814	19041-20001-31516	809 S MANSFIELD AVE	90036	4	132B181   272	5084002014	R3-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.06017	-118.34153	8/26/19CHANGES TO APPROVED SET REMOVING OPTIMIZER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9815	18041-20000-31466	5107 W LOS HERMOSOS WAY	90027	4	153B193   169	5588002026	RE11-1	Central	Hollywood	Hollywood United, Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM			PC Approved	08/20/2018 12:00:00 AM	ADDRESS	34.11415	-118.30244	new SFD 600 amp service.  plan check for power only.  this is plan check only.  permit fees paid under application number 16010-30000-03948.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9816	10041-10002-12657	263 WORLD WAY	90045	11	087B165    13	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	33.94461	-118.40469	FROM EXISTING MDP, NEW FEEDERS TO PANEL LP4 WHICH WILL SUPPLY EQUIPMENT TO PROVIDE POWER AND LIGHT FOR TWO MOBILE DWP SUBSTATIONS FOR CONSTRUCTION.  LOADS ON PANEL LP4 INCLUDES A 15KVA UPS(PWR & LIGHTING FOE TRAILER/SUBSTATIONS) AND TWO SETS OF FEEDERS  TO SUPPLY POWERS TO FANS COOLING THE SUBSTATIONS XMRSNEW UNMANED ELECTRICAL METER BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9817	16041-10000-27281	8707 S FALMOUTH AVE	90293	11	093B153    11	4118008***	LAX, R3-1	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		2766.03	Electrical	Electrical	Apartment			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Expired	09/12/2018 12:00:00 AM	ADDRESS	33.95447	-118.43473	PC FOR A FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING THE EXISTING FA PANEL, ANNUNCIATOR, AND 1 SMOKE DETECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9818	17041-10000-21891	16729 W CALLE DE CATALINA	90272	11	138B117    79	4431042***	(Q)RD3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Closed	11/16/2017 12:00:00 AM	ADDRESS	34.07583	-118.55058	PC for a Ground mount PV with central inverters and backup battery. Total system size of 11.4 KW AC.System include  36 solar modules and  2 central inverters 7.6  and 3.8 kw. 2 batteries rated at 5kw each. *********************************************************Building permit under 17020-10000-00939	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9819	13041-10000-21982	21650 W OXNARD ST 9TH FLOOR	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	TITLE 24 PLAN CHECK ONLY. HIGH RISE. 781 SQFT. EMERGENCY LIGHTING. WORK ON THE 9TH FLOOR. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9820	13041-20000-30498	4612 N LARKWOOD AVE	91364	3	168B097   574	2074042019	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.15509	-118.62789	PV1 TRANSFORMERLESS SYSTEM TOTAL SYSTEM SIZE 9.5KW. 38 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9821	14041-10002-35575	13160 W RIVIERA RANCH ROAD	90049	11	132B137   174	4425025001	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM			PC Approved	03/06/2017 12:00:00 AM	ADDRESS	34.06037	-118.49606	Pc for a lost set of plans (Permit was not pulled).RTI wet stamp to be provided under original paln (10K).Attached is additional set for a supp. (approved) for minor changes on the field due to building inspection.  Power plan check for a new house with new 600-Amp service.Separate permits for the feed barn and the stalls/stable	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9822	17041-20000-07343	14540 W HAYNES ST	91411	6	180B149   534	2236015018	[Q]CR-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.18951	-118.45022	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR SCHOOL. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9823	19041-20001-03962	12941 W STRATHERN ST	91605	2	189B161   307	2304015003	(T)RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.21595	-118.41597	Expedite per appliant request Plan check for PV roof mounted system and battery back up system, PV system size: 4.8KW DC, 16 PV Modules and 1 inverter(7.6KW) and 1 LG Chem battery 9.89kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9824	15041-20000-37866	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM			PC Info Complete	11/10/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24, PC FOR ENERGY ONLY. NEW INDOOR KIOSK FOR A COMMERCIAL MALL (BRATWORKS NATURAL GOURMET HOT DOGS). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 294 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9825	13041-10000-31540	9714 N VALJEAN AVE	91343	12	201B137   564	2677015016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.24696	-118.48704	PV1, Install 6.75 kW DC roof-mounted photvoltaic system for a 1-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 27 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9826	13041-20000-01789	3195 N DONA MEMA PL PV-1	91604	2	159B169   689	2381007013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.12856	-118.37983	Plan check for PV sfd. Transformerless. 6.48kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9827	13041-10002-30047	3619 N WESLIN AVE	91423	4	162B157   955	2386013003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.13648	-118.43091	Expedited RSES plan check per applicant request.(((PV1, Install 11 kW DC roof-mounted solar array, interconnect with service panel. Multiple transformerless inverters. 44 modules: HANWHA # HSL60P6-PB-4-250TW))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9828	15041-20000-01617	187 E 48TH ST	90011	9	111A205    81	5109003024	R2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	33.99936	-118.27227	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system.16  327W pv modules across 2 strings (8+8).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9829	16041-10000-44772	2342 W 31ST ST	90018	10	120B189   555	5052007014	R1-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.02637	-118.31898	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.12KWdc / 2.58KWac.(12)MODULES-SOLARWORLD SW PLUS 260M(12)ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9830	17041-10000-22648	9841 N AIRPORT BLVD 1210	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	PC FOR OFFICE TI IN A HIGH RISE. TITLE-24 ENERGY ONLY.SCOPE INCLUDES NEW LIGHTS IN (E) OFFICE ALL CIRCUITS ARE EXISITING. TOTAL AFFECTED AREA 1992 SQ.FT.BL# 17016-10000-11480PERMIT PULLED UNDER 17041-70000-21514 (MULTIPLE UNITS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9831	19041-10000-18541	2331 S BROADWAY	90007	9	121-5A205 112	5126034005	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	ADDRESS	34.02741	-118.26861	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9832	07041-10002-08990	1155 S WESTMORELAND AVE 1-12	90006	1	129B197   743	5076019001	R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			04/26/2012 12:00:00 AM	05/18/2012 12:00:00 AM		Permit Finaled	08/22/2012 12:00:00 AM	ADDRESS	34.04916	-118.2894	New 3 story 12 unit appartment with two levels of underground parking.  Variance has been filed to separate FA plans.   lost plans , switch gear change from  stand up to wall hang.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9833	18041-10000-11386	3159 S PURDUE AVE	90066	11	120B157   760	4250021015	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.02299	-118.43153	PC for two Tesla powerwalls 11.6kW for SFD, backup panel and load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9834	16041-20000-19806	540 S CATALINA ST	90020	10	135B197   936	5502022019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.06411	-118.29524	$0 permit fee is due to State Senate Bill SB 1222.  PV2.  Install 48.96 kW roof mounted PV system.  (2) separate PV systems on building occupying same rooftop.  System 1 of 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9835	19041-10000-25956	3031 W OLYMPIC BLVD	90006	10	129B193   261	5080032009	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Apartment			07/08/2019 12:00:00 AM			PC Info Complete	02/26/2020 12:00:00 AM	ADDRESS	34.05278	-118.30125	Full plan check for a NEW 6 STORY 14 UNIT APARTMENT over (1)  PARKING GARAGE. Scope include (1) 800-AMP 120/240V 3phase 4wire service with 3-typical unit. total common lighting area is 7,232-SQ FT .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9836	17041-10000-39382	5300 W CENTURY BLVD STE 124	90045	11	090B173   119	4129030043	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	33.94512	-118.37276	T-24, PC FOR ENERGY ONLY. TI TO FIRST FLOOR STE 124. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2872 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9837	14041-10000-18019	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	33.79072	-118.29449	Removing load brom branch circuit and adding X-Ray generator in existing health care facility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9838	18041-10000-24832	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	10/27/2020 12:00:00 AM	PIN	33.92817449	-118.43220714	"INSTALL 3 NEW 480V, 3 PH, 20HP STORM WATER PUMPS IN A CLASS 1 - DIV 2 AREA IN THE CORNER OF ""G"" STREET & ""7TH"" STREET."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9839	18041-30000-05280	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	33.94502	-118.40714	Plan check power and energy  LAX Project 5  T3 Enabling(Ternimal 3) Delta Sky Way new power and lighting system added for new SCCP at Level 1, new power added for power seating at level 3. Total area: 17,540 sq ftB#18016-10000-03811	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9840	15041-20000-38222	15910 W VENTURA BLVD #600	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.15561	-118.47969	TI to an existing office building on 6th floor of a high rise build. All electrical equip. are existing. PC for Energy only. Total area: 1,975 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9841	16041-20000-17826	11120 W WEDDINGTON ST	91601	2	171B173   320	2350018029	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.1669	-118.37317	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from retail to warehouse. Total lighting area = 4,510 sq. ft.Note: Building permit has been issued under 16016-30000-05656	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9842	19041-20001-10397	8333 N KENTLAND AVE	91304	12	192B097   374	2004005005	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.22041	-118.61822	expeditepv1install roof mounted pv system sized 7.6KW AC with battery 5KW interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9843	11041-10000-25538	701 S LINCOLN BLVD	90291	11	111B145   898	4239005030	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	33.9995	-118.46452	PLAN CHECK T24 ENERGY REMODEL OF TAKE-OUT RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9844	10041-20001-04897	2530 E CINCINNATI ST	90033	14	129A225   348	5177033028	R3-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2037.20	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM			PC Approved	04/12/2011 12:00:00 AM	ADDRESS	34.04626	-118.20433		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9845	16041-20000-15992	524 W ORD ST	90012	1	133-5A213 121	5407025900	R4-1	Central	Central City North	Historic Cultural	Yes	2071.02	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	02/16/2021 12:00:00 AM	ADDRESS	34.06104	-118.24181	PLAN CHECK FOR ENERGY FOR A NEW RESTROOM IN A PARK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9846	18041-10000-03798	333 S GRAND AVE STE 1455	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC for office remodeling T-24 energy only. (Suite 1455). Scope includes retrofitting existing fixtures. Total affected area is 1490 Sq.FtB# 17041-10000-37341	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9847	13041-10000-09730	700 S FLOWER ST SUITE 3100	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM			PC Approved	04/16/2013 12:00:00 AM	ADDRESS	34.04835	-118.25882	T24 plan check for single office floor TI.  Highrise building.  8030 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9848	14041-20000-00176	3249 N CAHUENGA BLVD WEST	90068	4	159B181   733	2429010004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.12921	-118.34863	(($0 permit fee due to senate bill 1222 from 2012)))PV2 COMMERCIAL ROOFTOP SYSTEM. USING 3 INVERTERS. TOTAL OF 30KW AC. PV INTERCONNECTION IS 240V 3PHASE 4 WIRE. WITH DELTA CONNECTION 3 PHASE INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9849	10041-10000-24560	1888 S CENTURY PARK EAST 2nd floor	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.06104	-118.41402	Remodel the second floor for the tenant - First Republic Bank.  Electricai, energy, emergency.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9850	10041-10000-03579	515 S FLOWER ST 3rd Floor	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	03/01/2010 12:00:00 AM		Permit Finaled	03/15/2010 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for T-24 Energy in existing office spaces on the 3rd Floor.  Permit is for new branch ckts and work on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9851	14041-20000-24390	16338 W KEELER DR	91344	12	213B137   125	2605016036	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.28326	-118.48723	PV1 SFD, TOTAL SYSTEM SIZE 6.4KW AC USING MICROINVERTER ENPHASE M215. TOTAL OF 30 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9852	11041-10002-17230	3041 W 7TH ST	90005	10	132B197   169	5077011018	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Apartment			05/29/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.05992	-118.29006	changes to approved set of plans(11041-20001-17230). fire pump cable from MI to thwn and pump changed from 30HP to 50HP.additional sump,booster,jockey,and condensate pumps.Changes to approved set of plans. Removal of fire pump from emergency source. Changes to single line diagram, minor changes to branch circuits. Packet is included showing all changes. NO CHANGES TO LIGHTING.  Site is in a Methane Buffer Zone Level I, with a pressure less than 1 per report. New 133 unit residential building.  Building is 4 story plus subterenean garage.  Plan check is for energy and power.  Fire alarm will be submitted separately.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9853	16041-10000-03767	2563 S MILITARY AVE	90064	5	123B157   354	4256022025	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.03521	-118.43087	PV1 roof mounted solar installation to a singe family home. Inverter: 6.0 kWac, (26) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9854	19041-10000-52427	2200 N STRADELLA ROAD	90077	5	153B145   205	4377030003	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Expired	11/03/2023 12:00:00 AM	ADDRESS	34.11256	-118.46263	(E-PLAN)NEW PV1 ROOF MOUNTED INSTALLATION WITH A SERVICE OF 225 AMPS. INSTALLTION INCLUDES 44 MODULES (LG LG370Q1C-V5), 44 MICROINVERTERS  (ENPHASE IQ7PLUS-72-2-US), AND 1 COMBINER BOX  SYSTEM SIZE: 16.28KW DC; 12.76 KW AC*NOTE: PANEL UPGRADE SHALL BE PULLED UNDER A SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9855	15041-10000-22134	1801 E 41ST PL STE D	90058	9	114A213   137	5116029059	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.00713	-118.24109	REMOVE EXISTING HID LIGHITNG FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9856	19041-10001-02298	13115 N TELFAIR AVE	91342	1, 7	222B141   327	2604002050		Central, North Valley	Sylmar, Wilshire	MacArthur Park, Sylmar	YES	1066.04, 2134.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.30778	-118.47865	EXPEDITE FEEPLAN CHECK FOR ROOF MOUNTED 166.5KVA PV2 SYSTEM CONSISTING OF 3 CENTRAL INVERTERS (5)SE33K-US WITH 500 MODULES USING P860 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9857	13041-20000-10312	6635 N FALLBROOK AVE	91307	12	180B097   170	2038040005	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.18998	-118.6262	Full plan check for new Starbucks inside Target.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9858	17041-10000-33826	1149 S BROADWAY 8TH FLR	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.03859	-118.26015	PC FOR OFFICE TI IN A HIGH RISE BUILDING FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 292 SQ.FT.B# 17016-10000- 27201ONE (2) NEW ENCLOSED MODULAR WALLS OFFICES AND PRE-CONFIGURATION OF WORKSTATIONS AT OPEN OFFICE AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9859	15041-10000-17732	12001 W VENTURA PL 500	91604	2	162B165    80	2368002001	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.14403	-118.39307	Energy plan check for an office T.I  ; Main scope includes new receptacles and lighting. total area is 10,055 SQ feet. Note. permit fee is paid under #15041-90000-16192.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9860	12041-20000-19972	9260 N OWENSMOUTH AVE	91311	12	198B105   107	2746011005	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.23872	-118.6017	fire damage new building power and energy plan check.  Plan check is for core/shell, with estimated loads only, future tenant will require full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9861	17041-10000-13625	504 S ALVARADO ST 208	90057	1	133-5A203 157	5154029026	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.06015	-118.27423	Plan check for power and energy.  Change of use from office to dental clinic.  Subpanels to remain existing.  New lighting and dental equipment loads.  Total area = 1,765 sq. ft.      Building permit #16016-10000-20806	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9862	13041-10000-10276	643 S OLIVE ST	90014	14	129A209   138	5144003***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM			PC Approved	04/22/2013 12:00:00 AM	ADDRESS	34.04713	-118.25526	Energy plan check for highrise bldg exterior facade lighting.  288 sq ft hardscape lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9863	13041-20000-34333	9320 N DEBRA AVE	91343	12	198B137   460	2676006017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.23991	-118.4904	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0 KWAC. 3 STRINGS FOR 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9864	16041-10000-33211	2185 E CENTURY BLVD 101-301	90002	15	093A217   275	6049019***	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	33.94668	-118.23304	PC for power only for a New 3 STORY 14 UNIT APARTMENT B3 BUILDING(Bldg. 6 of 8). Scope includes a new 600A 120/208V 3 phase 4 wire service/distribution board. One plan is submitted for multiple apartment buildings. B#16010-10000-02991	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9865	15041-10000-40576	1149 S HILL ST STE 475	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	TI TO AN EXISTING COMMERCAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 4020.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9866	17041-30000-39379	2022 W SUNSET BLVD	90026	13	139-5A207  92	5404003038	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Apartment			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	07/21/2020 12:00:00 AM	ADDRESS	34.07751	-118.2627	Plan check for new fire alarm system for 39 units appartment. Total fire alarm devices: 134 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9867	12041-10000-24577	7735 N OSO AVE	91306	3	189B113  1065	2107014041	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.21179	-118.5757	PV1 - PLAN CHECK 5.28KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING AURORA TRANSFORMERLESS INVERTER -TWO STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9868	19041-20000-09832	6705 N FALLBROOK AVE	91307	12	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.19106	-118.62366	T24 PLAN CHECK FOR TI OF EXISTING RESTAURANT SPACE. ADDITION OF LIGHTS AND EXHAUST HOODS, TOTAL SQUARE FOOTAGE = 8734SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9869	17041-10000-02299	8126 W BEVERLY BLVD	90048	5	138B173   443	5511005022	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Closed	03/21/2017 12:00:00 AM	ADDRESS	34.07591	-118.36673	PC for energy only for retail TI to existing store. Adding new lighting and power. Total area: 1537.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9870	14041-20000-10472	4507 N ATOLL AVE	91423	4	165B157    64	2360027021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.15241	-118.42053	pv1 single family dwelling. total system size 6.4kw ac using microinverter enphase m215. nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9871	18041-20002-14381	14200 W MULHOLLAND DR	90077	5	159B153   229	4379032011	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.13029	-118.44235	8/13/2018changes to an approved set of plans. changes to add load center. (((pv1install roof mounted pv system sized 10.4kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9872	16041-10000-27081	823 N POINSETTIA PL	90046	5	141B181   149	5526007031	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Apartment			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Issued	08/01/2016 12:00:00 AM	ADDRESS	34.08594	-118.34878	new fire alarm for a 2-story apartment building with 75 fira alarm devices and  1 fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9873	14041-10000-22961	630 S MASSELIN BLVD	90036	4	135B181   759	5508014037	R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	PIN	34.0637312	-118.35218585	PLANCHECK FOR T24 ENERGY. LEASING OFFICE TENANT IMPROVEMENT. 2328 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9874	17041-10000-22593	8026 N LANKERSHIM BLVD	91605	6	189B169   164	2311005018	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.21642	-118.38758	Plan check for power and Title 24.  Interior remodel of existing auto body shop plan check does not include the plan check for spray booth.  New lighting and receptacles in mech shop areas.  Total area = 1,400 sq. ft.        NOTE: Spray booth is not part of this submittal. (SEE COMMENTS ). Building permit #17016-10000-10735	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9875	17041-10000-40165	1541 N WILCOX AVE	90028	13	147A187    22	5547017003	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Closed	04/28/2021 12:00:00 AM	ADDRESS	34.09913	-118.33128	PC for power for temporary power installation. Connecting to existing 1600A 120/208V service in adjacent empty building (1545 N Wilcox Ave) owned by same owner.  Installing transformers, hoists,cranes, swing stage and placing boom. Architectural floor plan for future building layout shown on E1.01 for reference only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9876	14041-20000-24085	850 N LACHMAN LANE	90272	11	129B121   284	4419008024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	34.05069	-118.54497	PV1.  Install 5.60 kW DC roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9877	16041-10000-21571	2645 S CRENSHAW BLVD	90016	10	123B185   910	5050001027	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.03125	-118.33541	Full Plan check. New 5 story, mixed use building over one level basement parking garage. Ground floor is commercial, and the upper 4 stories are residential containing 50 apartment units. The main switchboard is rated at 2500 Amps 120/208v 3 phase 4 wire. 10 typical apartment units. Total sqft = 43,886.NOTE: fire alarm variance will be filed at later time.** Building app reference: 16010-10000-01830	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9878	16041-10000-29855	12067 W FOOTHILL BLVD	91342	7	213B165   562	2531006009	[T][Q]MR1-1-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.05	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.27837	-118.39887	PC FOR REBUILD OF 800A SERVICE SECTION FOR FIRE DAMAGED BUILDING. REBUILD 2 SECTIONS AND RECONNECT ALL EXISTING PANELS TO SWITCHGEAR. CHECKING NEW FAULT CURRENT VALUES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9879	16041-20000-17680	7311 W 90TH ST	90045	11	096B157   989	4119019020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	33.9552	-118.42281	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.  STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9880	14041-10000-25773	6600 N TOPANGA CANYON BLVD # 12	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI FOR RETAIL SPACE IN MALLPLAN CHK IS FORTITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9881	13041-10000-09916	18546 W ROSCOE BLVD #300	91324	12	192B125   923	2103005052	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.22047	-118.53793	Plan check power and energy. TI for medical office on 3rd floor (Suite 300).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9882	17041-10000-01644	1536 W YOSEMITE DR	90041	14	160-5A227 372	5689028902	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.13272	-118.19957	PC FOR LIGHTING REPLACEMENTS. NEW LED AND CFL REPLACE METAL HALIDE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9883	16041-10000-22534	18253 W LASSEN ST	91325	12	201B125    76	2731023001	RA-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.25017	-118.53122	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.848KWdc / 7.680KWac. STANDARD PLAN IS BEING USED.(24)AC MODULES-SPR-E20-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9884	19041-10000-13486	800 W 6TH ST 1000	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	Energy plan check for an office TI located in the 10th floor of a high rise building. Scope includes new lighting and equipment with a total area of 5,552-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9885	18041-10000-07253	2970 W OLYMPIC BLVD	90006	10	129B197   249	5078017023	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Issued	03/30/2018 12:00:00 AM	ADDRESS	34.05241	-118.29951	PC for T24 only for replacement of indoor lighting to LED fixtures with LED driver for Chase bank. Egress lighting is not part of the scope. Total area Indoor  is 4557sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9886	17041-20000-09071	12700 W VAN NUYS BLVD bldg 5,6	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	PV2.  Install roof mounted PV system sized 9.8kW to be interconnected with subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9887	19041-20000-08130	1803 S MESA ST LOT 11	90731	15	012B201   786	7456029037		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.72772	-118.28613	PLAN CHECK FOR NEW SOLAR ROOFMOUNT PV SYSTEM 3.015KW DC/2.88KW AC, SCOPE OF WORK INCLUDES (9) SUNPOWER SPR-X21-335-BLK-D-ACPV PANELS WITH INTEGRATED MICROINVERTERS, ON A NEW SFD TOWNHOUSE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9888	17041-10000-41796	439 N BONNIE BRAE ST	90026	13	138A207   313	5157024039	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	2084.02	Electrical	Electrical	Apartment			11/17/2017 12:00:00 AM			Reviewed by Supervisor	12/19/2017 12:00:00 AM	ADDRESS	34.07057	-118.26493	PV2, ROOF MOUNTED SOLAR SYSTEM TO AN APARTMENT BLDG USING A CENTRAL INVERTER (37) MODULES AND OPTIMIZERS. TOTAL SYSTEM SIZE IS 9KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9889	18041-20000-11453	7014 N BIANCA AVE	91406	6	183B129   494	2228028027	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Expired	05/04/2024 12:00:00 AM	ADDRESS	34.19808	-118.513	Plan check for the installation of a battery back-up system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9890	19041-10000-18024	12611 N ENCINITAS AVE	91342	7	219B141    75	2604035025	[Q]CM-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.29937	-118.47344	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9891	17041-20000-14854	919 S ALBANY ST 1st Floor	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.04913	-118.27045	TI to (E) commercial tenant space.  Plan check for energy.  Building permit issued under 16016-10000-29534.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9892	18041-10000-08275	19323 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.18698	-118.55464	PC for T24 only for replacement of existing indoor and outdoor lighting with new LED lighting for Chase bank.Total area 7800sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9893	18041-10000-08132	844 S MALCOLM AVE	90024	5	135B153   368	4360008006	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.0649	-118.43908	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES THE INSTALLATION OF TWO ENERGY STORAGE SYSTEM. TOTAL SYSTEM SIZE 27KWH/ 14KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9894	18041-20001-35841	4441 W SUNSET AVE F	90027	4	147A201   110	5542009028	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM			PC Approved	05/08/2019 12:00:00 AM	PIN	34.09786301	-118.2859835	05/08/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Lighting fixtures have changed. All changes have been reflected onto the fixture schedule and the Title 24 compliance forms.*****Original Work Description*****FULL PLAN CHECK FOR POWER AND ENERGY FOR - INTERIOR TI AT EXISTING SHELL FOR NEW GYM. - TOTAL CONNECTED APPROX. LOAD = 120A WITH AFFECTED AREA = 1321 S	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9895	15041-20001-13315	6316 N TOPANGA CANYON BLVD B-2110	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM			PC Approved	11/09/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	11/9/15: Change to an approved set: Replace gas Water Heater to Electric Water Heater, and Remove RTU3Permit under 15041-20000-13315TI to new commercial building (fitness studio). Plan check for power and energy. Adding new lighting including emergency. Total sqft. 5,442.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9896	17041-20000-17930	9043 N WOODMAN AVE #8	91331	6	195B153   158	2639033013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM			PC Approved	05/30/2017 12:00:00 AM	ADDRESS	34.23394	-118.43971	Tenant improvement & change of use from (E) retail to (N) ice cream parlor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9897	18041-10000-47325	10352 W RIVERSIDE DR 1-12	91602	4	165B177   144	2424005001	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			12/13/2018 12:00:00 AM	03/11/2022 12:00:00 AM		Issued	03/11/2022 12:00:00 AM	ADDRESS	34.15194	-118.35674	NEW 4 STORY, 12 UNIT  APARTMENT BUILDING  OVER  7037 SF  SUBTERRANEAN PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9898	17041-10000-18838	6280 N JACKIE AVE	91367	3	177B093   229	2035015010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.18381	-118.63591	PC for a PV1 roof mounted solar system in a single family home. Central inverter is 3.0 KW, 16 solar modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9899	18041-20000-26783	601 S FIGUEROA ST 50TH FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 Energy only in existing space lighting on 50th floor. Total newly connected load is less than 400A.  Total area: 11630 sq ft. B#18016-100000-21086	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9900	18041-10000-38505	725 S FIGUEROA ST # 4025	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	ALTERATIONS IN EXISITNG OFFICE SPACEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9901	10041-20000-21082	10823 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM	06/17/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.2668	-118.52366	T.I. for Rite Aid.  Install new 800 amp switchboard, subpanels, and branch circuits.  Plan check for power and energy.Note: All changes on the plans are clouded and authorized by the design engineer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9902	14041-10000-13226	18350 W ROSCOE BLVD	91325	12	192B125   686	2102001015	R4-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.22057	-118.53415	FA FOR RETROFIT IN cbre. 7 FLOORS (95.91ft) highrise . SPRiNKLERED: 1ST FLOOR. NON SPRINKLERED: 2-7TH FLOOR. replacement of existing fire alarm control panel (edwards IRC-3) with a new edwards EST3 system . All existing smoke detectors, pull stations, and modules are compatible to the new panel through an addressable analog driver controller 3-AADC1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9903	12041-10000-28087	2029 S CENTURY PARK EAST Suite #720	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/21/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN AN EXISTING OFFICE BULDING IN SUITE # 720 ON THE 7TH FLOOR. PLAN CHECK FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9904	19041-20001-14637	3626 W MONON ST pv2	90027	4	151-5A205 193	5433026024	RD1.5-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM			PC Approved	07/19/2019 12:00:00 AM	ADDRESS	34.10841	-118.27262	expeditepv2install roof mounted pv system sized 3.8KW AC with (1) tesla powerwall ESS interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9905	19041-10000-35102	1321 S SANTEE ST	90015	14	124-5A209 208	5133017011	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	09/26/2020 12:00:00 AM	ADDRESS	34.03464	-118.25882	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9906	13041-10000-35650	4019 S LINCOLN BLVD	90292	11	108B149  1856	4229005092	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	33.98967	-118.44737	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF RADIOSHACK. 1712 SQFT. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9907	17041-10000-03120	2029 S CENTURY PARK EAST 20th FL-LOBBY	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY. INTERIOR RENOVATION OF PUBLIC LOBBY ON THE 20TH FLOOR . CONNECTED LOAD < 400A. AFFECTED AREA 345 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9908	17041-10000-23635	221 N WESTMORELAND AVE	90004	13	138B197   570	5501008024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.07516	-118.28805	PC FOR  NEW OFFICE IN (E) CLASSROOMS TI FOR TITLE 24 ENERGY ONLY. INSTALLING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 363 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9909	13041-20001-05441	19314 W OLIVOS DR	91356	3	168B117   195	2175007001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.15832	-118.55369	SUPP. APPLICATION FOR CHANGE IN LOCATION OF SOLAR ARRAY. NO CHANGE IN ELECTRICAL PROPERTIES. PC ONLY FOR CHANGES. PERMIT ALREADY ISSUED UNDER ORIGINAL APPLICATION. Photovoltaic system on roof of single family dwellling with modules, inverters and PV subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9910	11041-10000-13636	2131 W 3RD ST	90057	13	135A205   136	5154018018	C2-1	Central	Westlake			2085.02	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM			Corrections Issued	08/11/2011 12:00:00 AM	ADDRESS	34.06336	-118.27369	REPLACEMENT OF CURRENT EXISTING 750KW GENERATORS.  THREE UNITS, LIKE SIZE.  EMERGENCY GENERATORS AT ST. VICENT  MEDICAL CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9911	16041-20001-09307	637 N GULF AVE	90744	15	030B205   758	7416017013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM			PC Approved	04/01/2016 12:00:00 AM	ADDRESS	33.77757	-118.27285	Previously approved plans were lost; plan check only for newly printed set to replace lost plan set.  (((Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9912	14041-20000-28285	21300 W VICTORY BLVD SUITE 260	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.18813	-118.59618	PC FOR TITLE 24.  COMMERCIAL OFFICE BUILDING.  REMODEL  OF LIGHTING USING EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9913	14041-10000-30578	380 WORLD WAY Space T83	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	TENANT IMPROVEMENT IN EXISTING COMMERCIAL SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9914	16041-10000-27620	3250 W SLAUSON AVE	90043	8	105B185  1434	4005005032	P-1, [Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	33.98753	-118.32923	PC for power and energy for change of use from office to dental.  Total area =  2,206 sq. ft.  Installing new lights, receptacles, dental equipment, and x-ray machines.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9915	18041-10000-05969	10611 N TUJUNGA CANYON BLVD	91042	7	207B197  1083	2557017007	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.26147	-118.29376	New PV1 rooftop on a SFD, (21) modules with P370, (1) central inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9916	14041-20000-09012	5417 N ENCINO AVE	91316	5	174B129  1000	2257003010	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Expired	05/09/2016 12:00:00 AM	ADDRESS	34.16951	-118.51631	PV1.  Install 7 kW roof-moutned PV system, interconnect with main service panel.  Standard plan.  Transformerless inverter: PowerOne Aurora PVI-6000-OUTD.  28 modules: Canadian Solar CS6P-250PX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9917	16041-10000-27003	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	33.95667	-118.4165	PC for energy only . Scope of work located in the 2nd floor of a 7-story commercial building. total area is 14605 sq ft. Permit fee is paid under 16041-10000-21615B#16016-10000-05096.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9918	11041-10000-17136	21329 W NORDHOFF ST	91311	12	198B105   169	2746010002	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM	08/12/2011 12:00:00 AM		Permit Finaled	09/14/2011 12:00:00 AM	ADDRESS	34.23562	-118.59582	NEW FIRE ALARM SYSTEM FOR AN EXISTING WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9919	10041-10000-13272	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	07/12/2010 12:00:00 AM		Permit Finaled	08/16/2010 12:00:00 AM	PIN	34.12750533	-118.21285206	T.I. for existing building.  Install general lighting in Gym hallway.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9920	13041-10000-24815	4451 N HAYVENHURST AVE	91436	5	165B137    90	2284010025	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.15159	-118.49304	PV1. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 11.52 KW. NEGATIVELEY GROUNDED CENTRAL INVERTER SYSTEM. 48 MODULES. 1 STORY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9921	13041-20000-20629	901 S SHERBOURNE DR	90035	5	132B169   105	4333021045	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			08/02/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.06077	-118.37948	Fire alarm panel replacement. No new devices. 17 unit apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9922	14041-20000-13967	11130 N BALBOA BLVD A	91344	12	210B133   327	2682021032	C2-1VL, C4-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.273	-118.50196	Change of use from retail to banquet hall.    Install new branch circuits and lighting.  Plan check for power and energy.Expedite fee paid 06/03/14occupancy 984 occupant by building code permit # 14016-30000-07644	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9923	16041-10002-40676	1038 E CRUCES ST	90744	15	036B209   402	7426011051	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM			Not Ready to Issue	01/09/2017 12:00:00 AM	ADDRESS	33.79315	-118.2498	PV1, AN ADDITION TO AN EXISTING SOLAR PV SYSTEM ON A RESIDENTIAL ROOF-TOP. ADDING 2.25KWac TO AN EXISTING 5.0KWac PV SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS 7.25KWac. (9)MODULES-HYUNDAI HIS-S280RG(1)MICROINVERTERS-M250-60-2LL-S2XNOTE: PERMIT IS PAID UNDER PCIS#16041-90000-40676	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9924	19041-10001-03120	6901 W WESTCHESTER PKWY APF	90045	11	093B161     3	4119006913	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	33.95391	-118.41344	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED DELTA 1. CHANGES INCLUDE ADDING A 2000A DISTRIBUTION BOARD TO THE SINGLE LINE DIAGRAM AND REVISING SITE PLAN FOR NEW 2000A DISTRIBUTION BOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9925	14041-10000-07178	17745 W SIDWELL ST	91344	12	219B129   657	2601071009	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.30083	-118.52096	New PV central X-formerless INV for a single family. 8.25 kw system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9926	12041-10000-29016	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	33.87528	-118.29083	INSTALL FUEL CELLS WITH 1200A MAIN BUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9927	13041-10000-24627	5867 S CENTRAL AVE #200	90001	9	108B209  1458	6007003900	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	33.98775	-118.25672	First time tenant -Panda Express in retail building(((((((((New single story retail building.  New service, new panels, new ckts.  Full plan check.  Core and shell only.  No tenant build out. application 12041-10000-30236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9928	19041-10001-21095	420 E BOYD ST	90013	14	129A213   362	5147006001	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.04601	-118.24206	Change to an approved set by adding devices throughout most of the ckts on the floor plan as built. Batteries and voltage drop also being recalculated. All changes under delta-6 only.(((pc for new FA system for commercial building (offices and retail) , 1 FACP and 144devices.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9929	12041-20000-30290	15114 W HAMLIN ST	91411	6	180B145   616	2235019013	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.18831	-118.46251	Photovoltaic system on roof of single family dwelling using standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9930	12041-10000-02493	719 S BROADWAY	90014	14	127-5A209  53	5144014037	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM	03/19/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.04483	-118.25393	PLAN CHECK POWER FOR CORE AND SHELL FOR EXISTING BUILDING. TWO  800A SERVICE SUPPLYING BUILDING. SEPERATE PERMIT AND PLAN CHECK FOR FUTURE TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9931	17041-20000-39123	6322 N FALLBROOK AVE	91367	3	177B097    15	2039020012	(Q)C2-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.18527	-118.62312	Service consolidation/upgrade - 120/240V 3ph-4w 600 A rated equipment.  Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9932	14041-10000-06101	11436 N OSTROM AVE	91344	12	213B133   749	2697017034	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.27844	-118.50694	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN SINGLE STORY HOME. SYSTEM IS TRANSFORMERED & SIZE IS  kW ON NON-STANDARD PLAN. TOTAL NUMBER OF MODULES IS 20, IN 2 STRINGS VIA DC COMBINER BOX. (20) MODULE: SOLAR WORLD 275W MONO(1) INVERTER: SUNNYBOY SMA-5000-US(240V)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9933	19041-20000-05948	8927 N WINNETKA AVE	91311	12	195B113    54	2781035051	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			Verifications in Progress	07/31/2019 12:00:00 AM	ADDRESS	34.23323	-118.57124	Change of use to cultivation facility.  Plan check for power and energy.  Building permit under 19016-20000-03151.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9934	13041-10000-09415	5825 W SUNSET BLVD SUITE 100	90028	13	147A191    51	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM			PC Approved	04/12/2013 12:00:00 AM	ADDRESS	34.09824	-118.3165	TI to the first floor of a 2-story office bldg.  1683 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9935	15041-20000-00016	11940 W ROSCOE BLVD	91605	6	192B165   516	2310001021	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.22147	-118.39374	PV1. Install roof mounted PV system sized 6.0 kW. Interconnected with main service pannel.(16) Sunpower SPR327NE Modules (1) Aurora PVI-6000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9936	10041-20000-06839	3494 E PICO BLVD 1 ST FLOOR	90023	14	118-5A225 320	5190036804	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.0179	-118.20314	T. I FOR OFFICE AREA OF SO. CAL GAS COMPANY.  TITLE 24  CORRECTION ISSUED ON SUBMITAL 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9937	11041-10004-10270			4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	PIN	34.14989598	-118.43926559	PLAN CHECK ONLY FOR REVISION R2.  EVAC CONTROL PANEL WAS PUT BACK IN THE SAME PANEL., INSTALLED OCCUPANCY SENSORS IN THE WARE HOUSE 4 IN OFFICESS 2 IN RESTROOMS AND 1 IN PREP AREA. ALSO TWO CONTACTORS ADDED TO STAR BUCK AND PERP ROOM.  FOR LK/LKA  PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9938	17041-10002-24842	835 W JEFFERSON BLVD 7A & 7B	90007	9	121-5A201 201	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM			PC Approved	09/06/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	CHANGES TO APPROVED SET OF PLANS. CHANGES ONLY TO EM LIGHTING. NO LONGER ON EM PANEL. ONLY CONNECT TO TENANT PANEL WITH UNIT EQUIPMENT. NO OTHER CHANGES. PC ONLY. PERMIT FEES UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9939	14041-10000-15812	1 W WORLD WAY WEST	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	PIN	33.94461393	-118.39808495	Plan check for power and lighting.  Total area = 25, 595 sq. ft.Redevelopment of terminal 6 project.  Replacement of existing light fixtures, power outlets, equipment, low voltage devices, and primary facility electrical infrastructure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9940	19041-10000-28329	1856 W FAIR PARK AVE	90041	14	160-5A223 168	5686013020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/16/2019 12:00:00 AM	ADDRESS	34.1346	-118.2082	[E-PLAN] PV1. NEW ROOFTOP SOLAR SYSTEM WITH TESLA POWERWALL BATTERY CONSIST OF 16 MODULES (POWER XT-360), OPTIMIZERS (SE P400) AND 1 CENTRAL INVERTER (SE6000H-US). SYSTEM SIZE IS 5.76KW DC AND 6KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9941	10041-20000-07118	5555 W MELROSE AVE Roddnberry	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM			PC Info Complete	04/19/2010 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check T-24 Energy mandatory measures on 1st and 2nd floor (Roddenbery Building).  Relocating less than 50% of lighting fixtures in the area.  No new wattage being added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9942	19041-10000-13417	8617 S TRUXTON AVE	90045	11	096B165   641	4123003021	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.9592	-118.39369	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9943	17041-10000-41349	2201 E WASHINGTON BLVD	90021	14	118-5A215   6	5167019900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Issued	11/15/2017 12:00:00 AM	ADDRESS	34.01911	-118.23383	LUMINAIRE ALTERATION IN OUTDOOR TRASH COLLECTION AREA : REPLACING FLUORESCENT LUMINAIRE WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9944	19041-10000-50850	3617 S AVALON BLVD SUITE 200	90011	9	117A207-387	5121008039	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	04/22/2021 12:00:00 AM	ADDRESS	34.01296	-118.26553	FULL PLAN CHECK FOR POWER AND ENERGY. NEW 1600A SERVICE, 208/120V, 3 PHASE. SCOPE OF WORK INCLUDES CHANGE OF USE OF A WAREHOUSE TO A MEDICAL SERVICE FACILITY.  TOTAL AFFECTED AREA IS 10527 SQAURE FEET. *********************************************CHNAGE OF USE FROM WAREHOUSE TO MEDICAL OFFICE BUIDLING 5492 SF MEDICAL OFFICE BUILDING TENANT IMPROVMENT SUITE TO A PORTION OF AN EXISTING 20,000 SF BLDG. UPGRADING BUIDLING TO ALLOW FOR A FUTUURE I-2 OCCUPANCY BY CHANGING BUIDLING TYPE FROM III-B TO III-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9945	18041-20000-12616	707 W WILSHIRE BLVD STE 4900	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	Plan check for Title 24 only in existing high rise office T.I. T.Y. Expantion.Total area: 1,150 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9946	16041-10000-30120	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	T-24, PC FOR ENERGY ONLY. T.I. OF THE EXISTING RESTAURANT INSIDE BLOOMINDALES. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2548 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9947	13041-10000-33192	627 S CARONDELET ST	90057	1	133-5A203 113	5141006006	R4-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Public Safety Only			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.06079	-118.28023	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING  FOR A SINGLE STORY SENIOR CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9948	19041-10000-42201	6957 N FIGUEROA ST	90042	14	159A229   340	5480009019	R1-1, RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.12876	-118.18798	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9949	19041-20001-00252	12751 W MILLENNIUM	90094	11	102B161  1175	4211033020		West Los Angeles				2756.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	12/31/2019 12:00:00 AM	ADDRESS	33.9761	-118.41651	Revision of equipment ratings/lighting and power detail changes.  All changes clouded and identified.(((Plan check for power and energy. Project site is (5) retail tenant spaces of an existing commercial building. Project scope is tenant improvements and common areas and restrooms. Total lighting area = 12,536 sq. ft.Note: Building application has been generated under 18016-30000-41269)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9950	19041-20001-32571	10814 N VANALDEN AVE	91326	12	207B121   861	2718014001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.26613	-118.54836	09-19-2019 Changes to an approved set of plan, Changes include down size Service panel to 200A and derate main circuit breaker to 175A, update PV system size: 10.73KW DC, 10.5KW AC CEC, 10KW AC STC.All changes has been clouded. Fees $0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9951	12041-10000-13070	4900 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.09786	-118.29626	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT FOR HOME INFUSION PHARMACY, PREP , WORK AREAS, STAFF OFFICES AT KAISER MEDICAL OFFICE (GROUND FLOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9952	17041-20000-01475	13039 W ADDISON ST	91423	4	171B161   976	2358026022	RE15-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Closed	04/25/2017 12:00:00 AM	ADDRESS	34.16136	-118.41718	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9953	08041-10001-22186	626 S ALVARADO ST	90057	1	133-5A203 184	5141001019	C2-2	Central	Westlake		YES	2089.03	Electrical	Electrical	Apartment			08/29/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.05869	-118.27519	Modification to an approved set of plan.  Approved set of plans to be included.  Changes are indicated by Delta 6.  Plan check is for energy and power.  <<<<<<New apartment complex.  Permit is for new service, new equipment, new dist. boards, new panels, new ckts.  P/C is for Power and Energy.  VARIANCE FOR FA SEPARATION REQUIRED.>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9954	18041-10000-47691	12553 W VENICE BLVD	90066	11	111B153   286	4246027010	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.00288	-118.43575	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL.  SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 1702 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9955	18041-10001-42703	734 S MAIN ST	90014	14	127-5A211 186	5145001001	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.04318	-118.25216	"PC PER APPLICANT REQUEST TO REVIEW UPDATED SINGLE LINE TO MATCH FIELD INSTALLATION. THIS IS PLAN CHECK ONLY PERMIT PAID UNDER MASTER.TI IN AN EXISTING 4 STORY OFFICE BUILDING. INSTALLING NEW LIGHTS IN THE COMMOEN AREAS. THE TOTAL NEW ADDED LOAD IS LESS THAN 400 AMPS. (SUBJECT TO FIELD INSPECTION).T-24 ENERGY ONLY. EACH NEW TENANT REQURES COMPLETE PLAN CHECK. BUILDING PERMIT"" 18016-10000-05811"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9956	13041-10000-13652	5080 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	ADDRESS	34.02028	-118.35491	pc for energy only. permit to be pulled at EPC counter ONLY.TI FOR MONEY SHOP IN EXISTING RALPHS MARKET. 180SF. less than 400A per applicant. see inspection for permit fees	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9957	18041-20001-16033	14634 W LIMEDALE ST	91402	6	201B149   718	2650024002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.2444	-118.45167	05/16/2018 Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV1 system. Addition system size is 3.23 kWac and consists of (15) modules, (15) micro-inverters, and (1) load center. Total system size is 7.31 kWac.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9958	15041-20000-38574	8857 N LARAMIE AVE	91306	3	195B113    94	2781032031	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.23153	-118.57343	Plan check for PV roof mounted system addtion to existing system. System size: 3.0kW. with 9 modules and 1 inverter(3.0kW). Existing system: 10kW System with 2 inverters(5.0kw ) connected to load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9959	10041-20000-10946	601 S FIGUEROA ST 37th floor	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check T-24 Energy general/emergency for the corridor area on the 37th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9960	09041-10001-01052	141 N UNION AVE	90026	13	135A207    44	5159008024	RD1.5-1	Central	Westlake	Greater Echo Park Elysian	YES	2084.02	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM			PC Approved	01/18/2011 12:00:00 AM	ADDRESS	34.06576	-118.26534	REVISED SITE PLAN /SINGLE LINE DIAGRAM TO SHOW THAT THE SERVICE EQUIPMENT IS LOCATED OUTSIDE  ADJACENT TO THE BUILDING; SEALS ARE PROVIDE FOR THE UNDERGROUND PULL SECTION TO PREVENT METHANE ENTERING THE  CONDUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9961	17041-10000-18066	6303 N OWENSMOUTH AVE FLOOR 9	91367	3	177B105   123	2146029016	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.18474	-118.60182	Plan check for power and Title 24.  T.I. to 9th floor of existing office highrise building.  New power and receptacles.  New load > 400 amps.  Total area = 23,164 sq. ft.demand reading complete.        Building permit #17016-10000-14298	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9962	14041-10000-10231	13033 W TERRA BELLA ST	91331	7	204B161    25	2620027012	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.25946	-118.41701	PV1.Install 4 kW DC roof-mounted solar array on a 2 story-house, interconnect with main service panel.(1) Transformerless inverter: SOLAREDGE #SE3800A-US-ZB-U(16) Modules: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9963	15041-10003-40734	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Issued	03/22/2017 12:00:00 AM	ADDRESS	34.04538	-118.26389	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED ON PLANS ISSUE 12. CHANGES INCLUDE REVISING EXTERIOR LIGHTING FLOOR PLANS, ADDING ONE NEW BRANCH CIRCUIT FOR LIGHTING, AND REVISING TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9964	12041-10001-23372	11701 W WILSHIRE BLVD suite#11	90049	11	129B145   573	4265010084	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM			PC Approved	11/05/2012 12:00:00 AM	ADDRESS	34.04949	-118.4611	5050 SF tenant improvement project for a restaurant. New lighting and circuits. EPC is for T24. (permit was pulled under 12041-90000-23372)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9965	11041-20000-00347	2626 W COLORADO BLVD	90041	14	163-5A219 162	5682002024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.14192	-118.22342	T.I. to existing Target store.  Install general lighting in Starbucks and food areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9966	16041-20000-17823	245 S MAIN ST C11	90291	11	111B141   545	4286017***	(Q)C4-2D	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	33.99681	-118.47872	TI TO AN EXISTING COMMERCIAL BUILDING ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 5348	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9967	19041-10002-12471	4060 W WASHINGTON BLVD	90018	10	126B185   996	5060008004	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.01	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Issued	08/22/2019 12:00:00 AM	ADDRESS	34.03968	-118.32772	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include revising single line diagram to reflect as built. Adding a 225KVA transformer and a 400A panelboard. Relocating loads to new 400A panelboards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9968	18041-10000-39407	16741 W SCHOENBORN ST	91343	12	192B137   231	2689012013	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.2228	-118.49793	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9969	17041-10000-09743	520 S BURNSIDE AVE GARAGE # 7	90036	4	135B181   237	5509005014	R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.06571	-118.34981	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 80500 SQ. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9970	18041-10000-09709	931 W OXFORD AVE	90292	11	105B149   457	4229002013	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	33.98604	-118.44881	PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL (200A). PV IS EXISTING. TOTAL BATTERY SIZE INSTALLED : 10KWAC / 27KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9971	13041-10000-24641	19411 W CYPRESS POINT DR	91326	12	213B117    66	2822024025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.28349	-118.55658	PV1 ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING USING [MODULE: ND-250QCS AND MICROINVERTER: ENPHASE # M215]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9972	16041-20000-14575	1111 S FIGUEROA ST 1st Floor	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.04338	-118.26581	"TI in 1208 sq. ft. concession space - ""Cooler by Budweiser"" at Staples Center.  Plan check for energy."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9973	17041-10000-28789	3644 E ROSEVIEW AVE	90065	1	147A219    72	5454016027	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Issued	12/08/2017 12:00:00 AM	ADDRESS	34.09836	-118.22229	PC FOR TESLA BATTERY IN SFD WITH EXISTING SOLAR. INCLUDING NEW LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9974	18041-30002-09125	13003 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM			PC Approved	04/16/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	04/16/2019 Changes to an approved set of plans. Changes have been made to the outdoor lighting. All changes have been reflected onto the Title 24 compliance forms. This plan check is for changes to the outdoor lighting only.*****Original Work Description*****FULL PC FOR A CORE AND SHELL,  MULTI-TENANT BUILDING. SCOPE OF WORK INCLUDES NEW SERVICE UPGRADE TO 120/208, 3PH, 1600AMPS. NEW OUTDOOR LIGHTING AND RECEPTACLES. TOTAL OUTDOOR  SQ. FT. 10992.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9975	18041-10000-26815	7950 W FOOTHILL BLVD	91040	7	204B193   174	2559006022	C2-1VL, R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.25936	-118.30626	PLAN CHECK FOR T24 ONLY, TI ON (E) MCDONALD. INSTALL NEW LIGHTINGS AND RECEPTACLE. EXIT SIGNS ARE EXISTING TO REMAIN AND NOT PART OF THE SOW. TOTAL AREA 3,478 SQ.FT(B# 18020-10000-02104)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9976	14041-20001-15798	17329 W RAYEN ST	91325	12	195B129   212	2768018004	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.2323	-118.51236	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11KW AC USING 2 CENTRAL INVERTERS. NONSTANDARD PLAN. TRANSFORMERLESS INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9977	16041-20000-02125	142 E 82ND PL	90003	9	099B205  1327	6030009014	R3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	33.96444	-118.27239	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel. (16) Solarworld SW275 Modules(16) SolarEdge P300 Power Optimizers(1) SolarEdge SE3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9978	17041-10000-43472	5175 N AVENIDA ORIENTE	91356	3	171B125   405	2161023013	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.16538	-118.5318	PV1 10.8KW AC roof mounted system with (30) AC modules interconnecting through the  subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9979	12041-20000-04125	923 N COLE AVE	90038	4	144B185  1087	5533021008	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	34.08776	-118.33004	energy plan check manufacturing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9980	10041-10000-21574	10201 W PICO BLVD BLDG 5, 6	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM			Verifications in Progress	01/25/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	TENANT IMPROVEMENT TO (E) OFFICE SPACE, REMOVAL OF PARTITION WALLS, 2ND FLOOR ADDITION OF 230 SQ FT MEZZANINE; NO EXTERIOR WORK DONE .Electrical include power, lighting, and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9981	17041-10000-01808	10424 W WHIPPLE ST	91602	4	165B177   719	2424015005	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.1478	-118.35793	Plan check for PV roof mounted system SFD. System size: 5.0kW with 14 modules HYUNDAI HIS-S350TI and 1 inverter(5.0kW)  connected to 600 MSP	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9982	14041-10000-28581	4816 W FOUNTAIN AVE	90029	13	147B197  1139	5540015017	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			10/15/2014 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.09524	-118.29387	220 device fire alarm system for a new apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9983	18041-20001-25494	9121 N OAKDALE AVE 1st & 2nd-Floors	91311	12	198B113   153	2761001068	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Issued	07/26/2018 12:00:00 AM	ADDRESS	34.23622	-118.56725	Plan check for Title 24 only. Project site is an existing 2-story office building. Project scope is a tenant improvement. Total lighting area = 34,049 sq. ft.Note: Building application has been generated under 18016-20000-11721*****Previous Work Description*****New receptacle and floor outlets	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
9984	11041-10001-08498	955 S VERMONT AVE #N	90006	10	129B197    14	5078009027	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	34.05403	-118.29182	TI IN AN EXISTING OFFICE AREA IN UNIT #N.   PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.  <<<<<EXISTING PARTIAL PERMIT # 11041-10000-08498  ADDITIONAL PERMIT REQUIRED.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9985	13041-20001-21950	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM			Reviewed by Supervisor	01/21/2014 12:00:00 AM	ADDRESS	34.2312	-118.36756	DEMO INTERIOR OF FORMER RALPHS MARKET. CREATE 7 NEW LEASE SPACES, 3 OF THEM SHELL ONLY AND THE REST TI IMPROVEMENTS. REMODEL EXTERIOR CANOPY AND PARKING LOT. NEW 120/208 2500A SERVICE. (((pc for changes to approved set of plans. changes clouded delta D, change to service section. reduction in design. original permit fee to be recalculated and issued under inspection. this application is for plan check only for changes. ))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9986	16041-10000-45356	2643 E 25TH ST BLDG 7	90058	14	117A219   115	5168022006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.01546	-118.22426	PC FOR POWER AND ENERGY. ALTRATION OF EXISTING BUILDINGS AND CONVERT TO AN EXPANDED PROCESSING IDUSTRIAL AREA. UPGRADING SERVICE TO 4000A., ADDITION OF 8 MCC UNITS. TOTAL AREA OF LIGHTING  36265 SQ FT.B# 16014-10000-03632.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9987	17041-20000-22140	13938 W BURTON ST	91402	6	192B153   902	2213003004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.22059	-118.43695	Plan check for solar pv system, roof-mounted on SFD.11.34kW ungrounded system.(42) EnPhase S280 microinverters.(42) 315W pv modules.$22.29 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
9988	19041-10000-14218	17200 W VENTURA BLVD 224	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.16035	-118.50769	"PC FOR T.I. FOR EXISTING RESTAURANT TO PANDA EXPRESS.SCOPE INCLUDES NEW PANELS, CIRUCITS AND LIGHTS. TOTAL AFFECTED AREA 2574 SQ.FT B#19016-10000- 11051 ""COMPLY WITH DEPARTMENT ORDER effective date 12/10/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".   CEIS Case Number is 838199."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9989	19041-20000-37235	6701 S CENTER DR WEST 7TH FLOOR	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	PLAN CHECK FOR RESTROOM REMODEL ON THE 7TH FLOOR OF A COMMERCIAL HIGH RISE. LIGHTS ONLY. T24, TOTAL SQUARE FOOTAGE = 402 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9990	16041-20000-13027	1200 S SANTA FE AVE 1ST FLOOR	90021	14	123A217   315	5166007011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			PC Info Complete	07/05/2016 12:00:00 AM	ADDRESS	34.02944	-118.22979	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement/change of use. Total lighting area = 2,717 sq. ft.  Power plan check per applicant request.Note: Building permit has been pulled under 16016-10000-02703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9991	18041-10000-21980	2049 S CENTURY PARK EAST Suite#1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN AN EXISTING OFFICE AREA IN SUITE #1940 ON THE 19TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9992	15041-10000-27962	4701 E YORK BLVD	90042	14	156A223   126	5474016011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			Reviewed by Supervisor	09/09/2015 12:00:00 AM	ADDRESS	34.12274	-118.2128	PC FOR POWER AND ENERGY. CORE AND SHELL FOR COMMERCIAL BUILDINGS A AND B. UPGRADE FROM 400A SERVICE TO A 1000A SERVICE. TOTAL AREA = 5693 SQ. FT.  BUILDING B IS FED BY PANEL PA6 FROM THE MAIN SERVICE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9993	17041-20000-10990	11059 W SHERMAN WAY	91352	2	183B173    97	2315028017	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.20136	-118.3722	PLANCHECK FOR T24 ENERGY. TCHANGE OF USE FROM MARKET, AUTO REPAIR GARAGE TO CHURCH / OFFICES. 3092 sqft.BUILDING PERMIT # 16016-20000-30157	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9994	14041-10001-05675	3414 W 76TH ST	90043	8	099B185    92	4012021023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	33.97072	-118.33158	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(13) MODULES: TRINA SOLAR TSM-250PA05.18(1) SOLAREDGE SE3000A-US.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9995	14041-10000-08530	8500 W BEVERLY BLVD # 790	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) 1,460 S.F. RETAIL SPACE IN A COVERED MALL. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9996	11041-10000-23608	2046 N MORGAN HILL DR	90068	4	151-5A191 319	5587014016	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.10784	-118.31399	12.54 kw pv system for a sfd. one story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
9997	16041-10000-04747	2853 E 6TH ST	90033	14	124-5A225 269	5185018012	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2043.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Expired	03/12/2018 12:00:00 AM	PIN	34.03457751	-118.20637985	PV1, New Solar system on existing residential roof-top. Total system size is 3.8kW AC system.(14) Modules-CS6P-260P(1) Inverter-FONIUS 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
9998	10041-10001-20720	325 S BOYLE AVE 1st floor	90033	14	127-5A221  72	5174012009	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Apartment			07/07/2011 12:00:00 AM			PC Approved	07/07/2011 12:00:00 AM	ADDRESS	34.04403	-118.2199	Modification to existing approved set of plans.  They are re-using what is exsisting rather that buying new lights as well as changing what was originally scheduled to be installed with new light fiztures.  The use of the space is I2 occupancy and is still excempt.  <<<<<<<Emergency lighting plan check for lobby and office areas as shown on page E-4.0.  The applicant provided a Certificate of Occpancy to show that the building is an I2 Occupancy that is not required to comply with part 6 of the California Energy Standard.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
9999	19041-10000-11804	13160 W MINDANAO WAY 1ST FLOOR	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	10/14/2020 12:00:00 AM	ADDRESS	33.98501	-118.43726	PC FOR ALTERATION TO EM. SYSTEM IN A MEDICAL FACILITY. SCOPE INLUDES ADDITION OF EM. PANELS, CIRCUITS AND EQUIPMNET ARE TO BE RELOCATED. CIRCUITS AND EQUIPMNET ARE TO BE RELOCATED.UPGRADE IS TO COMPLY WITH NEWER CODE.  NO NEW ADDED LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10000	16041-10001-43692	10250 W SANTA MONICA BLVD # 1900	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"This is plan check only, permit is covered under master 16041-10000-43692.  Changes to approved set due to architectural (floor plan) changed, noted under Delta-4 and 5.  Tenant ""Urban Decay"" Ste. 1900."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10001	19041-10000-39898	11047 1/2 W COHASSET ST	91352	2	186B173   398	2315013019	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.20676	-118.37206	Plan check for a STANDARD PV1 5kw AC / 5.7KW DC roofmounted system. Scope includes (1) inverter, (20) modules and optimizers interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10002	19041-10000-05932	361 S SPRING ST	90013	14	129A211    30	5149019034	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Closed	08/10/2021 12:00:00 AM	ADDRESS	34.0492	-118.24814	600 AMP TEMP POWER FOR CONSTRUCTION OF A NEW 12-STORY HOTEL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10003	18041-10000-07466	1824 N HILLHURST AVE	90027	4	150B201  1276	5590018001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.10439	-118.28725	PC for T24 only for new lighting in change of use from medical to restuarnat. Installing two new panels, new lights, receptacles and equipment. Total area is 1714 sqft. B# 18016-10000-04257.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10004	15041-20000-39355	15651 W SHERMAN WAY	91406	6	183B141    72	2206038012	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.20139	-118.4744	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,020 sq. ft.Note: Building application has been submitted under 15016-20000-25741.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10005	15041-10000-17165	6801 W HOLLYWOOD BLVD #STR-03	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	Energy plan check for a retail ( Victoria's Secret) storage room T.I .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10006	16041-10000-28383	4583 W LEXINGTON AVE	90029	13	144B197   269	5542019039	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	09/10/2016 12:00:00 AM	ADDRESS	34.09357	-118.28889	PV1 roof mounted solar system installtion to a single family home. Installing 18 microinverters rated at 320 watts each for a total system size of 5.76Kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10007	18041-20000-25519	10212 W KALUA DR	91040	7	201B181   105	2543033016	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Issued	07/09/2018 12:00:00 AM	ADDRESS	34.24999	-118.35271	Plan check for a PV1 roof-mounted PV system. System size is 3.36 kWac and consists of (12) modules and (12) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10008	19041-10000-40312	3220 E OLYMPIC BLVD	90023	14	118-5A223  72	5190028017	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.01953	-118.20966	PLAN CHECK FOR TITLE 24 ONLY FOR OFFICE SPACE, TOTAL AFFECTED AREA = 1750 SF.Permit for Inspection correction under 19041-10000-34150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10009	14041-10001-05707	6547 W 83RD ST	90045	11	099B165  1101	4108009016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	33.96383	-118.40344	EXPEDITED RSES PLAN CHECK PER APPLICANTREQUEST.{{PV1, INSTALL 6.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(25) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10010	14041-20000-08975	8542 N PONCE AVE	91304	12	192B097    38	2004013029	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.22591	-118.62126	PV1 ROOF MOUNTED PV SYSTEM ON SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW. USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10011	15041-20000-43232	5001 W MELROSE AVE	90038	13	141B193   569	5535017007	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.08365	-118.30951	Plan check for power only. Project site is an existing 2-story mixed use building. Project scope is the replacement of tenant panels and new distribution section for the residential section.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10012	13041-10000-23370	1743 S SHENANDOAH ST	90035	5	129B169  1203	4303008023	R1-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.04712	-118.38288	PV1 11.13 KWdc 240V XFRMless. 1 STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-5000-OUTD-US, (42) MODULES # SOLARWORLD SW 265 MONO BLACK. UNGROUNDED SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10013	13041-20000-11160	6510 W FOREST LAWN DR '1-50'	90068	4	165B185   205	5581004021	(T)(Q)C1.5-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.14678	-118.33255	T24 FOR NEW BATHROOM FOR NON HIGHRISE 4 STORY PARKING STRUCTURE. 1421 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10014	15041-20000-26206	7249 N BAIRD AVE	91335	3	186B125   920	2118028047	(Q)R3-2	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			08/12/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.20259	-118.53747	PV2. ROOFMOUNTED SOLAR SYSTEM.  CENTRAL INVERTER SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 12KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10015	16041-10000-00719	1217 S LA PUERTA ST	90023	14	118-5A229 113	5191028005	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.01825	-118.19341	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.6KWac.(12)MODULES-LIFELINE ENERGY LLE-M260(1)INVERTER- ABB 3.6 PVI-3.6-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10016	15041-20000-40911	4919 N BLUEBELL AVE	91607	4	168B161   169	2357020004	R1-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.15993	-118.41174	PV1, roof mounted solar panel 11.4kW AC system interconnect with (N)225A service.(35) modules: LG315N1C-G4(1) inverter: SE11400a-usPower optimizer is used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10017	14041-20000-34811	572 E M ST	90744	15	033B209   126	7422020016	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	33.78899	-118.25626	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZE 5.0 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(16) SUNPOWER 327W MODULES(1) AURORA PVI-50000 TL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10018	15041-20000-25387	1737 N LAS PALMAS AVE 1-82	90028	13	148-5A185  43	5547010004	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			08/06/2015 12:00:00 AM			PC Info Complete	10/02/2015 12:00:00 AM	ADDRESS	34.1026	-118.33639	PERMIT PULLED AND FINALED UNDER 16041-10000-13840 STATUS CHANGES TO PLAN CHECK ONLY!Installation of new fire alarm system in new 82 unit apartment building.  Total number of devices = 502 + 1 FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10019	13041-10000-06024	8761 N WINNETKA AVE	91306	12	195B113   352	2781031017	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.22987	-118.57125	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. SINGLE STORY. TOTAL SYSTEM SIZE 11.27 KW SYSTEM. USING TWO CENTRAL INVERTERS. NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10020	15041-10000-12783	9034 N BURNET AVE	91343	7	195B145    46	2654006028	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.2348	-118.46302	New fire alarm system for a private middle school; scope includes (1) fire alarm panel, (1) power supply, (1) communication panel, and (120) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10021	18041-20000-37699	17829 W PALORA ST	91316	5	168B129   143	2182006012	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.15972	-118.52103	Plan check for energy storage system installed in to existing PV system, Energy storage system size: 40.5kWh, 3 Tesla Powerwall 13.5kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10022	19041-20000-25592	3916 N VINELAND AVE	91604	2	162B173   709	2378006011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.13901	-118.37005	Plan check for a PV1 roof-mounted PV system. System size is 14.19 kWdc/13.6 kWac and consists of (2) inverters, (43) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10023	13041-10000-29041	12611 W SAN VICENTE BLVD	90049	11	129B141   346	4405031005	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.05074	-118.48131	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A SINGLE STORY HOME. INTERCONNECTING WITH EXISTING 200A MAIN SERVICE . SYSTEM SIZE IS 3.888KW AC. WORK IS DONE ON MICROINVERTER STANDARD PLAN, WITH:(18) ENPHASE M-215 MICROINVERTER, AND (18) MODULES,CANADIAN SOLAR CS6P-250P.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10024	19041-20000-33261	12601 W BRANFORD ST	91331	7	201B161   835	2624014094	[T][Q]M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Issued	09/09/2019 12:00:00 AM	ADDRESS	34.24506	-118.40785	NEW COMMERCIAL BUILDING 400 AMP SERVICE FIRST TIME TENANT PLAN CHECK FOR POWER ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10025	17041-10000-39250	449 S MCCADDEN PL	90020	4	135B185   351	5507014014	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.06547	-118.3373	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 12.375KWDC / 10KWACSCOPE INCLUDES 39 MODULES WITH OPTIMIZER AND SINGLE INVERTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10026	15041-20001-43513	12113 N LOUISE AVE	91344	12	216B129    76	2606027059	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM			PC Approved	01/02/2016 12:00:00 AM	ADDRESS	34.29149	-118.51311	EXPEDITE PER APPLICANT REQUEST. (((((PV1 roof mounted installation to a single family home. Inverter: 10kw, 40 solar modules. total system size 10.0kWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10027	11041-20001-27235	1955 E CESAR E CHAVEZ AVE	90033	14	129A223    31	5175033028	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM			PC Approved	04/16/2012 12:00:00 AM	ADDRESS	34.04948	-118.21341	New panel ' F '  AIC rating changed from 10000 amps to 18000 amps, and panel F feeder changed to 7 feet from 25 feet.  Existing permit 11041-20000-27235.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10028	13041-20000-19238	4911 N SUNNYSLOPE AVE	91423	4	168B157   189	2359015001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	ADDRESS	34.15986	-118.42705	PV1 SINLGE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.9 KW. USING 16 MODULES. TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. 2STRINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10029	12041-10000-21935	3711 S AVALON BLVD	90011	9	115-5A207  42	5121008048	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.0125	-118.26557	Plan check for new lighting for sewing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10030	19041-20000-09097	20655 W ACRE ST pv1	91306	3	195B109   165	2780011012	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.22997	-118.58382	pv1install roof mounted pv system sized 9.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10031	17041-10000-05811	539 S CLARENCE ST	90033	14	126A219    49	5171007024	M1-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.03975	-118.22343	PLAN CHECK FOR POWR ONLY ON EXISTING HUBBLE STUDIO. SERVICE UPGRADE TO 1600 AMPS NEW PANELS AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10032	14041-20000-11550	7633 N MELVIN AVE	91335	3	186B117   108	2116009014	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.20947	-118.56047	PV1.  Install 6.75 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10033	15041-20000-26159	1230 N GULF AVE	90744	15	033B205   451	7415011008	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	33.78737	-118.27357	PV1. ROOFMOUNTED SYSTEM. SYSTEM SIZE: 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10034	19041-10000-25350	23332 W HAMLIN ST	91307	12	180B093   596	2036014006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.18887	-118.63571	0$ final fees per AB1414Plan check for a PV1 roofmounted 10.1KW system.  Scope includes (1) subpanel, (4) ckts, and (28) AC modules interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10035	18041-10000-28804	22351 W VENTURA BLVD	91364	3	174B101   510	2146012016	C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			Reviewed by Supervisor	08/09/2018 12:00:00 AM	ADDRESS	34.16907	-118.61427	FIRST TIME TENANT, STARBUCKS COFFEE; PLAN CHECK FOR POWER AND ENERGY. 1790 SQR FT. BLDG PERMIT: 18016-10000-24459	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10036	13041-10000-27895	1857 N PHILLIPS WAY	90042	14	157-5A227 146	5479018017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.12644	-118.20082	PV1, 8.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(2) inverters: {SOLAREDGE SE5000A-US, SE3000A-US}]. [(34)modules: {HANWHA {#HSL60P6-PB-4-250TW}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-AH4SM-2NA-Z}. (E) 125A MAIN. THE 250W OPTIMIZERS WILL BE CHARGED UNDER NON-DWELLING POWER EQUIPMENT. LOAD CENTER WILL BE USED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10037	18041-20000-42064	11369 N FERRARA LANE	91326	12	213B109    78	2701049038	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.27828	-118.58098	pv1install roof mounted pv system sized 8.1Kw AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10038	17041-20000-11607	11371 W RIVERSIDE DR	91602	4	168B173   525	2353028071	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.15729	-118.37833	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 1564.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10039	18041-30000-34699	601 S FIGUEROA ST 24th floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for T24 only, Tenant improvement to (e) Office, area under the scope: 3,185 sq.ft (B# 18016-10000-28567)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10040	11041-20000-26726	5740 W WILSHIRE BLVD	90036	4	135B177   577	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM			PC Approved	12/14/2011 12:00:00 AM	ADDRESS	34.06225	-118.35359	Existing office space (Third floor).  Relocating existing light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10041	18041-20000-10728	9674 W HIGH RIDGE DR	90210	5	153B157   322	4384032030	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2018 12:00:00 AM			Reviewed by Supervisor	04/25/2018 12:00:00 AM	ADDRESS	34.11293	-118.42576	Plan check for power only. Project site is a new 2-story single family dwelling with a basement.Note: Building application has been generated under 16010-20000-05295	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10042	11041-10000-14401	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	07/12/2011 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	NEW FIRE ALARM SYSTEM FOR BRAND NEW BUILDING - HYPERION WATER TREATMENT PLANT, DIGESTER GAS COMPRESSOR FACILITY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10043	18041-10000-02028	5847 N JAMIESON AVE	91316	5	174B129    83	2159023026	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.17686	-118.5216	Plan check for a 5kw AC / 7.7kw DC Pv1 roof mounted system. Scope includes (1) 5kw inverter, (22) modules and optimizers interconnecting through the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10044	11041-20000-06870	19781 W RINALDI ST	91326	12	210B117   379	2701040040	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	06/08/2011 12:00:00 AM	ADDRESS	34.27517	-118.56478	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR T.I. - REMODEL EXISTING BANK OFFICE SPACE WITHIN EXISTING GROCERY MARKET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10045	16041-10000-24040	310 E FLORENCE AVE	90003	9	102B205   871	6022017024	[Q]CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.01	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	33.97455	-118.26901	TITLE 24 (3975 SQ. FT.) FOR TI IN EXISTING COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10046	16041-20001-17300	8139 N CORBIN AVE	91306	3	189B117    78	2106014001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.21779	-118.56245	EXPEDITE PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.SYSTEM IS TO BE ADDED TO AN EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10047	14041-20000-34456	7820 N AMPERE AVE	91605	2	189B161   809	2303014049	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.21255	-118.41781	PV1 SFD. TOTAL SYSTEM SIZE 8.62 KW AC USING TRANFORMERLESS INVERTER. USING TOTAL OF 34 MODULES. 2 INVERTERS. 4 STRINGS     CONNECTED WITH EXISTINGS 3.8 KW SYSTEM. TOTAL SYSTEM SIZE INCLUDING EXISTING: 11KWNote: solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10048	11041-10002-17761	9247 N VAN NUYS BLVD 1-56	91402	6	198B149   342	2651009003	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Apartment			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.23862	-118.45064	MODIFICATIONS TO APPROVED SET UNDER APPLICATION NUMBER 11041-10001-17761. DELTA- A CHANGES TO SHEETS E0.3, E3.0 AND E3.1**************************************************************************11041-10001-17761 DESCRIPTION: REVISIONS TO APPROVED SET OF PLANS- FEEDERS ON THE HOUSE DISTRIBUTION BOARD ARE CHANGRD FROM AL MC CABLES TO AL BUILDING WIRES; ALARM/STROBE AND HARD WIRED SMOKE ALARMS WITH 9V BATTERY BACK INSTALLED IN THE TWO SEEING AND HAIRING IMPAIRED UNITS.)))))))BRAND NEW 56 UNIT APARTMENT BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  FIRE ALARM WILL BE ON A SEPERATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10049	18041-10002-12498	2361 W 31ST ST	90018	10	120B189   456	5052005003	R1-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2018 12:00:00 AM			PC Approved	07/03/2018 12:00:00 AM	ADDRESS	34.0266	-118.31977	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF SERVICE - SEE SITE PLAN - CHANGES UNDER DELTA 1PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE IS 6KVA CONSISTING OF 1 CENTRAL INVERTER (SE6000A-US) WITH 24 PANELS WITH (P320 POWER OPTIMIZERS)SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10050	14041-10000-35153	5723 W MELROSE AVE	90038	13	141B189   279	5534036018	C2-1D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.0836	-118.3252	Title 24 plan check only.  Total area = 852 sq. ft.T.I. to existing office space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10051	14041-20001-31858	11938 W RUNNYMEDE ST #A & B	91605	6	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.20563	-118.39354	Fee for expedite only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10052	19041-10000-50133	433 S SPRING ST 7TH FLR	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	TI IN AN EXISTING OFFICE AREA ON THE 7TH FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 8540 SFT INDOOR + 275 SFT OUTDOOR FOR THE TOTAL OF 8815 SFT.BUILDING PERMIT: 19016-10000-32386	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10053	12041-10000-14090	7802 N CLYBOURN AVE	91352	2	189B177   673	2466030009	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.10, 1222.00	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.21223	-118.3636	Plan checkf or power. 600A service upgrade. All loads are existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10054	15041-10000-10867	8500 S VERMONT AVE BLDG A	90044	8	097-5A199 185	6032013905	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	33.96105	-118.29134	"NEW DEVELOPMENT 3000 AMP SERVICE, CORE AND SHELL,  PC FOR POWER AND ENERGY. THIS IS BULDING 'A' OF 7 BUILDINGS. TITLE 24 ENERGY CALCS FOR COMMON AREAS TO BE SUBMITTED AT A LATER TIME. ENERGY FEES ARE ESTIMATED BY BUILDING LOAD CALCULATIONS. (((PROPOSED  3-STORY RETAIL AND RESTAURANT BUILDING.THIS BUILDING IS KNOWN AS BLDG ""A""  TYPE VA W/ SPRINKLER SUBSTITUTION FOR FIRE RESISTANCE RATING. )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10055	13041-10000-30036	8014 W ELLENBOGEN ST	91040	7	210B193   368	2551037003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.27119	-118.30772	PV1.  Install 3.75 kW DC roof-mounted photovoltaic system interconnect with main service panel.  Transformerless inverter: SolarEdge SE3000A-US, power optimizers, and 15 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10056	13041-10000-17586	23903 S NORMANDIE AVE	90710	15	042B197   226	7438017***	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Info Complete	09/26/2013 12:00:00 AM	ADDRESS	33.80859	-118.2989	Plan check for the addition of 3 more microturbines in industrial plant.  Installation in hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10057	14041-10000-29768	11110 W OHIO AVE	90025	5	129B149    59	4324019013	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	34.05014	-118.44683	T.I  , office building title 24 and enrgy. 3 story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10058	18041-20000-01521	700 S FLOWER ST Ste 800	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10059	13041-10000-29531	7607 N RUDNICK AVE	91304	3	186B101   141	2012020082	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.2086	-118.6123	PV1.  Install 6.0 kW DC roof-mounted solar array, interconnect with main service panel.  Transformed inverter: Fronius IG 5100 NEG.  24 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10060	15041-20000-21216	7620 N RUDNICK AVE	91304	3	186B101   121	2012020059	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.20896	-118.6119	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.2 KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10061	17041-10000-32638	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	03/02/2022 12:00:00 AM	PIN	33.92817449	-118.43220714	PC FOR BIOTRICKLING FILTERS, CARBON TOWERS, PUMPS, BLOWERS AND ASSOCIATED EQUIPMENT FOR HYPERION RECLAMATION PLANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10062	16041-10000-03449	420 E 3RD ST	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Issued	02/18/2016 12:00:00 AM	ADDRESS	34.04686	-118.24182	T-24, TI TO A LOBBY SPACE IN A HIGH RISE BUILDING. NEW LIGHTING IN THE LOBBY AREA.  TOTAL SQ. FT. 2410.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10063	17041-10000-20581	6350 N LAUREL CANYON BLVD	91606	2	180B165   762	2334003027	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.18619	-118.39631	ART 517 - MEDICAL TI. PC FOR POWER AND ENERGY. NEW EXAMINATION ROOMS. NO CRITICAL CARE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10064	18041-20000-10352	5808 W SUNSET BLVD 6th Floor	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	TI to (E) commercial office space - 770 sq ft of open plan office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10065	17041-10000-33239	1313 W SEPULVEDA BLVD	90501	15	042B193   827	7347018096	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	33.81424	-118.30074	PC for power and energy for first time tenant fish restuarant.Installing 2 new panels, circuits, lights and equipment.Total area of 2803sqft. B 17016-10000-27013	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10066	12041-10001-30438	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010		Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	cHANGES TO APPROVED SET, CHANGES INCLUDE dELTA 1, 2, 6,7,8,10.  , APPLICANT WILL DROP OFF THE APPROVED SET FOR REFFERENCE.<<<<<<<<<<>>>>>>>>>>>EXISTING COMMERCIAL BUILDING COMPRISED OF TWO FLOORS AND A BASEMENT.  THE BUILDING HAS SUFFERED MAJOR FIRE DAMAGE.  THE FIRST AND SECOND FLOORS WILL BE COMPLETELY DEMOED AND THE BASEMENT WILL BE LEFT WITH BARE WALLS.  TWO NEW FLOORS WILL BE CONSTRUCTED OVER THE BASEMENT AND THRE T.I'S WILL TAKE PLACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10067	17041-10000-13976	15739 W VENTURA BLVD	91436	5	168B141   612	2261009012	C4-1L, R1-1, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.15563	-118.47654	PC FOR ENERGY AND POWER.  NEW MULTIPURPOSE 3-STORY COMMERCIAL BUILDING. SERVICE 2500 AMP, 120/208 3 PHASE. TOTAL AREA  16720 FQ FT.B# 16010-20000-041495/1/17: Applicant came back and decides to expedite the plan with a pre-cut check, Plan check engineer to verify if additional fee is needed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10068	12041-20000-21648	19755 W VANOWEN ST A2	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.19397	-118.56386	Plan check for power and energy. First-time tenant in a shopping center. Menchies. 1464 sqft. Suite A2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10069	16041-10001-03814	6314 W HOLLYWOOD BLVD	90028	13	148-5A187 367	5546009***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.1014	-118.32715	Revision to approved set. This is PC only for T-24, changes noted under Delta-2. Permit under master E#<<T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO CAFE/ BAKERY WITH DINING. SCOPE INCLUDES NEW LIGHTING AND THREE NEW PANELS. TOTAL AFFECTED AREA IS 1095 SQ. FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10070	13041-20000-20567	420-428 E BOYD ST	90013	14	129A213   362	5147006001	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			Reviewed by Supervisor	08/20/2013 12:00:00 AM	ADDRESS	34.04601	-118.24206	Existing service, new distribution equipment. Plan check for power and energy. Energy plan check was omitted during submittal; additional fees will apply. METHANE BUFFER ZONE.INTERIOR  & EXTERIOR   T.I.  TO 5 STORIES COMMERCIAL BUILDING & INSTALL  NEW ENTRY DOORS @ FIRST FLOOR RESTAURANT  & INSTALL NEW INTERIOR EXIT STAIRCASE &  NEW RESTROOMS  .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10071	16041-10001-00432	3351 S GAFFEY ST	90731	15	006B197     4	7469018904	OS-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.71374	-118.29306	01/10/2017 Changes to  an approved set of plans. Changes include relocate fire alarm devices and additional of 2 smoke detectors. Changes has been clouded as delta 1{{{{NEW FIRE ALARM SYSTEM TO A POOL AND BATH HOUSE BUILDING. 39 FIRE ALARM DEVICES AND ONE FIRE ALARM PANEL.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10072	12041-10001-09833	14800 S FIGUEROA ST	90248	15	075B201   141	6129001046	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	33.89809	-118.28288	Modification to a previously approved set of drawings to relocate transformer, lighting panel and  panels.          <<<<T.I. to an existing office building.  New lighting and circuits.  PLAN CHECK ONLY for Energy with Emergency lighting.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10073	17041-10001-14813	7541 N BECK AVE	91605	2	186B169   335	2316012041	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.20776	-118.38355	Supplemental PC for removal of optimizers and addition of a INNOVATIVE SOLAR INC inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10074	13041-20000-07454	21501 W ROSCOE BLVD	91304	3	192B105   592	2779036021	C2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Apartment			03/22/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.21994	-118.59892	Fire alarm for a new 81 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10075	19041-20000-50535	13263 N WHEELER AVE # 14	91342	7	225B157  1056	2512010026	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	PV1. Install 2.24 KW DC/2.03 KW AC roof mounted PV system.  (7) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10076	15041-10000-10549	10250 W SANTA MONICA BLVD #177	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	PIN	34.0586034	-118.41904766	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10077	16041-20000-09948	920 W HARRY BRIDGES BLVD	90744	15	027B205   665	7440007901	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM			PC Info Complete	04/05/2016 12:00:00 AM	ADDRESS	33.76949	-118.27079	Plan check for power and lighting. Project site is a new 1-story automobile repair garage/office building. Total lighting area = 6,108 sq. ft. Note: Building application has been generated under 16010-40000-00850	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10078	13041-10000-11318	15448 W VISTA HAVEN PL	91403	5	159B145   143	2279020004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	07/05/2013 12:00:00 AM	ADDRESS	34.13517	-118.46933	PV1 - PLAN CHECK FOR NEW 9.81KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10079	16041-10000-06124	5657 N FULTON AVE	91401	2	174B157   414	2343019003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.17371	-118.42268	PV1, rooftop solar installation, 5kWac system.(19) SW275 Mono Black(19)optimizers-solar edge P300(1) inverter-SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10080	16041-20002-43900	4719 N CALHOUN AVE	91423	4	168B153   478	2248028013	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.15663	-118.44231	changes to an approved set of plans.  change modules to hanwha q cells 280.  this is plan check only.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.(N) 3kW ungrounded system. (8) 265W pv modules. There is an existing 3.8kW ungrounded system installed on the SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10081	14041-10000-24956	7732 N DENSMORE AVE STE A	91406	6	189B141   249	2206011031	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.21117	-118.47699	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 2912 SQFT. STE A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10082	17041-10000-29805	1575 N GOWER ST B	90028	13	148-5A189 330	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	TI ON 3RD FLOOR. SUITE B. PC FOR T24 ENERGY ONLY. OFFICE UPGRADES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10083	17041-20000-45614	16025 W VENTURA BLVD	91436	5	168B141   547	2261022022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	12/11/2018 12:00:00 AM		Issued	12/11/2018 12:00:00 AM	ADDRESS	34.15641	-118.48198	Plan check for power and energy. TI/Remodel for (E) assisted living facility. New 300 kW 120/208V 3ph 4w emergency generator.  New loads and distribution feeding off existing service.  Building permit application #17016-20000-37696.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10084	15041-10002-40939	2710 S SEVERANCE ST	90007	9	121-5A201  14	5123003411	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.02896	-118.28161	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE DELTA 10 NOTES. SINGLE LINE RE-DESIGN TO BALANCE THE LOAD ON THE DELTA SYSTEM. INSTALLATION OF NEW TRANSFORMER TO STEP TO 208V AND BALANCE LOADS. THIS APPLICATION IS PC AND PERMIT FOR CHANGES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10085	10041-10000-05460	862 S MAIN ST	90014	14	127-5A209 294	5145015002	[Q]C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	12/14/2011 12:00:00 AM	ADDRESS	34.04148	-118.25466	New two story / with basement retail building.  Ref.#10044-10000-04775	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10086	16041-20000-21380	13612 W VICTORY BLVD	91401	2	180B157   959	2330012022	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.1865	-118.42988	Plan check Title 24 only in existing space T.I. for M & A Beauty. Total area: 1,860 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10087	17041-20000-35042	18734 W VENTURA BLVD	91356	3	174B121   566	2161008005	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.17088	-118.54186	Commercial tenant improvement.  Plan check for energy - 2597 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10088	17041-20000-40973	957 1/2 N HYPERION AVE	90029	13	144A201   168	5427008007	[Q]RD1.5-1D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Expired	10/19/2023 12:00:00 AM	PIN	34.08919116	-118.28158648	PV1.  Install 6.09 kW roof mounted grid tied PV system.  (21) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10089	18041-10000-33151	350 S MAIN ST	90291	11	109-5A143  98	4286004006	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	33.99499	-118.47656	Energy plan check for a pantry area  located in a commercial building with a total area of 630-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10090	15041-20000-39636	937 E 25TH ST	90011	9	118-5A209  36	5131021007	R3-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Apartment			11/24/2015 12:00:00 AM			PC Info Complete	02/12/2016 12:00:00 AM	ADDRESS	34.0203	-118.25559	NEW 3-STORY 8-UNITS APARTMENT BUILDING WITH PARKING GARAGE ON THE GROUND FLOOR. (1 UNIT & TYPE IA ON GROUND FLOOR; 7 UNITS & TYPE VA ON 2ND AND 3RD FLOOR) Full PC, 600A MSP.Fire alarm variance on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10091	17041-10002-12352	3604 N GLENRIDGE DR	91423	4	159B157    63	2272029023	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.13565	-118.4321	"Revision to approved plan to reflect addtion of PV meter on the plan. Changes under delta 1.This is a ""PLAN CHECK ONLY""***********************************************************************************PC for new rooftop solar PV. Total system size is 13.9KW and includes 41 SPR-X21-345-C-AC AC modules. one 125A load center ."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10092	17041-10003-35365	250 N BURLINGTON AVE	90026	13	136-5A207 263	5159009008	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			PC Approved	06/20/2018 12:00:00 AM	ADDRESS	34.06744	-118.26543	*expedited fee per applicantDesign change on permit# 17041-10000-35365. (54) modules, (1) SE11400A-US, (1) SE6000H-US on existing 600A, 120/240 V, 1ph, 3W service.<<<PC for rooftop solar for apartment building. Installing 70 new PV modules with optimizer and one SE9.0KUS inverter. Total system size is 9kW.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10093	15041-20002-39987	1627 S PANDORA AVE	90024	5	132B157   454	4326030026	R1-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.05883	-118.42617	02/03/2016 Changes to an approved set of plans. Changes have been made to the PV module mounting height.*****Previous Work Description*****Expedited per customer request.PV1. Install roof mounted PV system sized 5 kW. Interconnectd with main service panel.(19) SunEdison 325W Modules(19) SolarEdge Power Optimizers(1) Solar Edge SE5000A Inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10094	12041-10000-30153	222 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Apartment			12/14/2012 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/26/2016 12:00:00 AM	ADDRESS	34.05621	-118.25318	Plan check for new 2000 Amp service, new feeders, transforemers, and bus duct to feed distribution panels on each floor. Building D.  Location in methane buffer zone. No installation in hazardous area.  Each dwelling unit future connection under separate permit and shall require plan check. Fire pump on separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10095	17041-20000-24811	14956 W HARTLAND ST	91405	6	183B145   675	2220018004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.19517	-118.45954	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10096	12041-20000-27494	5947 N VARIEL AVE	91367	3	177B105    94	2149002025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.17846	-118.59315	Combine two separate office spaces.  Change to lighting and receptacles, relocate panel, new panel and circuits.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10097	13041-20001-35011	2421 N MORENO DR	90039	4	150A205   261	5432015011	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.10472	-118.26879	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 13.2KWAC. 47 MODULES AND 3 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10098	16041-10000-14745	100 WORLD WAY Space 123	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	TI  FOR  NEW COFFEE SHOP  AND STORAGE ROOM. Coffee Bean 7& Tea LeafPC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10099	18041-20000-19669	937 N CITRUS AVE	90038	4	144B181   680	5532011034	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Issued	06/18/2018 12:00:00 AM	ADDRESS	34.08825	-118.33978	***1600Amp Service not included.****PLANCHECK FOR POWER ONLY. New 1600 service, service equipment, and feeders for existing building.  Reconnect the existing subpanels to the new service.  recheck due to expired plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10100	13041-10000-11153	8231 N WOODMAN AVE	91402	6	192B153   835	2213016021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.22033	-118.43269	Tenant improvement in existing grocery store (Seafood City) with take-out restaurant to create dine-in area.  New casework, fixtures, and finish work. No alcohol consumption on site.Plan chk is for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10101	19041-20000-36908	2881 E PICO BLVD	90023	14	118-5A221  37	5169008005	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	34.01952	-118.2174	New power, lighting, and distribution for fire-damaged commercial office/warehouse building.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10102	13041-20001-36315	10210 N OAKDALE AVE CLASSROOM	91311	12	204B113   213	2726008001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM			PC Approved	12/09/2014 12:00:00 AM	ADDRESS	34.25596	-118.56656	Change of approved set of plan per applicant request.  (((PLAN CHECK FOR POWER AND ENERGY. CONSTRUCT NEW CLASSROOM BUILDING CONSISTING OF SIX (6) CLASSROOMS AND THREE (3) GROUP STUDY ROOMS.  1 OF 2. BUILDING PC # 13010-10000-04112)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10103	10041-20000-04318	6309 W ELEANOR AVE	90038	4	144B185  1292	5533017011	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM	03/10/2010 12:00:00 AM		Permit Finaled	03/18/2011 12:00:00 AM	ADDRESS	34.08992	-118.32704	T.I WORK IN RECORDING STUDIO. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10104	14041-20000-02565	839 N VIA DE LA PAZ	90272	11	129B125   758	4412004023	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			01/29/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.04598	-118.52757	pc for t24 energy only. new lighting in existing offices. total area 7724 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10105	11041-10000-25917	1510 N SAN PABLO ST 6th Floor	90033	14	135A225    62	5202004039	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/22/2011 12:00:00 AM	ADDRESS	34.06266	-118.20215	Plan check T24 Energy/Emergency T.I. to an existing office space on the 6th floor, USC Medical Campus HCC-1. No patient care area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10106	14041-20000-22557	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.20103	-118.38536	Title 24 plan check only for a Swe-research and evaluation lab in a medical building. Total area is 677 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10107	17041-10000-04523	10101 N CASABA AVE	91311	12	204B113   478	2741006009	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Expired	04/21/2024 12:00:00 AM	ADDRESS	34.25393	-118.57619	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDNENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.28KWac.(29)AC MODULES-SUNPOWER SPR-X21-345-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10108	14041-20000-11771	10110 N JORDAN AVE	91311	12	204B105   545	2747015065	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Expired	05/26/2016 12:00:00 AM	ADDRESS	34.25459	-118.60373	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 4.2 KW AC USING 20 MODULES. TRANSFORMERLESS INVERTERS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10109	17041-10000-03894	9135 N INDEPENDENCE AVE	91311	12	198B105   166	2746009044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.23675	-118.59135	Plan check for Title 24 only in existing space, remove outdoor HID lighting fixtures and replace with new LED lighting fixtures. Total area: 25,950 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10110	15041-10000-39892	19801 W NORDHOFF PL #109	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.23568	-118.56464	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10111	19041-10000-14646	720 N VIRGIL AVE	90029	13	142-5A201 217	5539019022	C1-1D	Central	Hollywood	East Hollywood	YES	1914.20	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.0843	-118.28669	PC for T24 for an existing market. Affected area is 1220 SQFT.((PROPOSED TENANT IMPROVEMENT OF AN (E) TAKE OUT MARKET. REMODEL COUNTER IN SERVICE AREA WITH NON-BEARING PARTITION WALL.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10112	19041-10001-03203	10371 W NORTHVALE ROAD	90064	5	123B161   667	4318036016	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	34.03284	-118.41378	Delta 1 only. adding 2 disconnect switch per DWP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10113	17041-10000-17033	8640 W 3RD ST STE 202	90048	5	138B169   564	4334011021	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.07338	-118.38114	NEW DENTAL OFFICE ON 2ND FLOOR. PC FOR POWER AND ENERGY. NO SURGICAL.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10114	15041-20000-36201	535 S KINGSLEY DR	90020	10	135B193   769	5503023019	P-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			10/28/2015 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.06428	-118.30317	PC for power and energy on a New 7-story, 72 unit apartment building over a podium parking level and 1 level of subterrean parking garage.  total area is 72,755 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10115	17041-10000-11108	222 S CABRILLO AVE	90731	15	018B197  1455	7451015902	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.7418	-118.29437	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  4875 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10116	19041-20000-09363	2801 W OLYMPIC BLVD	90006	10	129B197   188	5078006011	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2133.20	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM			PC Info Complete	03/15/2019 12:00:00 AM	ADDRESS	34.05281	-118.29496	T24 PLAN CHECK FOR EXISTING FAST FOOD RESTAURANT, LIGHTS AND OUTLETS, REPLACEMENT OF EXISTING LIGHTS WITH LEDS, USING EXISTING CIRCUITS, TOTAL SQUARE FOOTAGE = 1380 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10117	19041-20000-50322	16233 W VANOWEN ST	91406	6	183B137   268	2224001901	M1-1, [Q]M1-1, [Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	11/12/2020 12:00:00 AM		Permit Finaled	05/10/2021 12:00:00 AM	ADDRESS	34.19405	-118.48697	Distribution, power, and lighting for commercial space.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10118	18041-20001-29475	10880 W WILSHIRE BLVD Ste 700	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.05885	-118.44283	12/10/2018 Changes to an approved set of plans. Fixture locations have been revised to accomodate removable room partitions.*****Original Work Description*****Existing commercial office remodel.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10119	10041-10000-12012	10351 W WASHINGTON BLVD	90232	10	117B165   199	4208006017	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	08/27/2011 12:00:00 AM	ADDRESS	34.01918	-118.40198	Ti in two story office building. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10120	16041-10000-16223	710 W HARRY BRIDGES BLVD BERTH 144	90744	15	027B205   546	7440009***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	33.7693	-118.27062	PC FOR RELOCATION OF 6.6KV OUTLETS TO ACCOMODATE LARGER CONTAINER SHIPS. 2 OUTLETS TO BE RELOCATED. PC FOR NEW FAULT CURRENT RATINGS AND MEDIUM VOLTAGE CABLE INSTALLATION. PLUGS LOCATED AT BERTH #144	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10121	13041-10000-33638	4415 S CENTRAL AVE	90011	9	112-5A209  93	5108028023	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.00344	-118.25677	pc for energy only. permit to be pulled at EPC counter only. 13016 20 20989 Install (N)stair enclosure from basement to 2nd floor.  Install nonbearing partition for lobby area at (E)elevator on each floor.  Remodel (E)restrooms on 1st & 2nd floor.  NO CHANGE IN USE/PARKING/FLOOR AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10122	19041-20001-14833	4423 N SHERMAN OAKS CIR	91403	5	166-5A145  88	2283019003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.15116	-118.47048	Change of system design.  Main on 200A load center changed from 200A to 125A.  (((Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (2) battery back-up units to an existing PV system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10123	19041-10001-13289	11880 W JUNIETTE ST	90230	11	105B165   304	4220005034	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM			Reviewed by Supervisor	04/24/2019 12:00:00 AM	ADDRESS	33.98564	-118.40381	PV1. NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 7600 INVERTER,  (20) MODULES + OPTIMIZERS, AND (1) TESLA POWERWALL . TOTAL SYSTEM SIZE IS 6.4KWAC AND 7.2KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10124	14041-20001-14397	19918 W ARCHWOOD ST	91306	3	180B113   253	2134010020	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.19179	-118.56735	Changes from previously approved plans.  Relocate inverter, subpanel, and main service panel.  No changes in module and inverter models.Note: Permit is under the original application.*****Previous Description*****PV1.  Install 4.08 kW roof-moutned utility-interactive PV system.  Transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10125	16041-30000-15407	445 S FIGUEROA ST Suite 1950	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for Title 24 only. Project site is a suite within an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 3,365 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10126	12041-10000-04365	1043 S KINGSLEY DR	90006	10	129B193   528	5080025009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			02/27/2012 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Expired	04/29/2014 12:00:00 AM	ADDRESS	34.05133	-118.30329	Plan check for 29.6KW roof mounted photovoltaic system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10127	13041-10000-01855	6222 W SANTA MONICA BLVD	90038	13	144B189   698	5534022033	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM			PC Approved	02/25/2013 12:00:00 AM	ADDRESS	34.09053	-118.32534	electrical permit to be pulled at plan check onlyenergy plan check with emergency lighting less than 400 Aaddition: PROPOSED NEW 2-STORY OFFICE BUILDING (SHELL BLDG)..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10128	18041-10000-21252	909 E COLON ST	90744	15	036B209   293	7426003001	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	33.79161	-118.25174	REPLACING HID LUMINAIRES WITH LED TYPE IN A WAREHOUSEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10129	15041-10000-10883	1120-1122 W 6TH ST	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.05418	-118.26297	INSTALLATION OF FIRE ALARM SYSTEM 4 FIRE ALARM CONTROL PANELS, 2 CONTROL PANEL AND 1936 FIRE ALARM DEVICES. FEES ESTIMATED PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10130	18041-10000-28633	1402 W 240TH ST	90710	15	042B193   775	7439012006	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.80709	-118.30173	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10131	16041-20000-05992	18614 W VINCENNES ST	91324	12	198B121   294	2763007008	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.24075	-118.53877	PV1.  Install 6.8 kW AC roof-mounted PV system.  Central inverter standard plan.  (32) Trina TSM250PD05.05 modules with (2) inverter ABB PV1-3000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10132	18041-10000-46438	601 W 5TH ST 11TH FL	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.05049	-118.25386	TENANT IMPROVEMENT IN OFFICE PLAN CHECK IS FOR TITLE 24 ND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10133	15041-20000-23005	6220 N TOPANGA CANYON BLVD Space 9080	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.1841	-118.60553	Plan check for power and Title-24 (energy).  Total area = 300 sq. ft.  T.I. to commercial first time tenant.  New lighting and cooking equipment in existing kiosk.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10134	13041-20001-32112	5021 N BELLAIRE AVE	91607	2	171B161   965	2357010009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.1619	-118.40955	"((3/14/2014- CHANGES MADE TO APPROVED SET OF PLANS. CHANGE THE CONDUIT SIZE FROM 3/4"" TO 1/2"")))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC. 34 MODULES AND 2 INVERTER"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10135	17041-10000-01966	1109 N AVALON BLVD	90744	15	033B205   793	7420021022	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	33.78512	-118.26303	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, TOTAL AREA 13325 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10136	16041-10000-40756	6060 N LANKERSHIM BLVD	91606	2	177B169  1096	2338005008	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.18135	-118.38435	PC FOR POWER AND ENERGY. TI TO (E) RESTAURANT. CHANGE OF USE FROM RESTUARANT TO COFFEE SHOP. CONNECTED LOAD >400 A. TOTAL AREA 2876 SQ FT. B# 16016-10000-18207	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10137	16041-10000-32417	9301 N TAMPA AVE MACY'S	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	T-24, PC FOR ENERGY ONLY. T.I. FOR MAC COSMETIC STATION WITHIN ( E )  MACY'S RETAIL BUIDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1176 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10138	18041-20001-43803	9200 N GLENOAKS BLVD	91352	6	198B173   111	2408001003	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	34.2363	-118.37296	"Plan check for hazardous location, install Emergency stop Switches (ESD) to existing CNGInspector request. see inspector correction.this is plan check only.  ********Previosu Work Description************************EXPRESS PERMIT FOR INSTALLING FOUR ADDITIONAL LOW VOLTAGE (24VDC) ""EMERGENCY STOP SWITCHES"" (ESD) TO  EXISTING CNG'S. PLAN CHECK MAY BE REQUIRED, SUBJECT TO FIELD INSPECTION.  (Per Inspector Lee & Inspector Ferguson)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10139	19041-10000-49498	1100 S SAN PEDRO ST J06	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.03515	-118.25194	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10140	19041-20000-15589	2929 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Closed	11/05/2021 12:00:00 AM	ADDRESS	34.10429	-118.24391	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10141	17041-10001-14793	1313 W SILVIUS AVE	90731	15	006B193    78	7470025026	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2017 12:00:00 AM			Reviewed by Supervisor	09/12/2017 12:00:00 AM	ADDRESS	33.71542	-118.30662	ADDITION OF BATTERY STORAGE UNIT TO EXISTING SOLAR INSTALLATION. PERMIT ALREADY ISSUED UNDER MASTER. THIS APP IS PC ONLY. PC INCLUDES NEW LOAD CENTER AND MAIN BREAKER DERATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10142	14041-10001-03107	725 N HARVARD BLVD	90029	13	141B193   456	5535030003	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	ADDRESS	34.0843	-118.30409	Expedited RSES plan check per applicant request.{{PV1, Install 4.5 KW DC roof-mounted solar array on a 1-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U(18) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10143	18041-20000-27481	426 N ALEXANDRIA AVE	90004	13	141B197  1157	5520015008	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Apartment			07/23/2018 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	12/21/2020 12:00:00 AM	ADDRESS	34.07853	-118.29804	full plan check for power and energy for new 600 amp service. (18) panels with loads, a car charger, and elevator. T24 included total square footage = 13489 sf. see comments for fire alarm variance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10144	13041-10000-33945	6514 W SANTA MONICA BLVD	90038	13	144B185   772	5533013028	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.09057	-118.33159	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING. REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH ENW FLUORESCENT FIXTURES. PROJECTED AREA ANTICIPATED IN SCOPE OF WORK IS TO BE 5000 SQ FT. REPLACING (11) FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10145	13041-10000-33348	12345 W CHANDLER BLVD 1-23	91607	2	171B165    90	2347006015	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			11/27/2013 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.16879	-118.40229	PLAN CHECK FOR POWER AND ENERGYN NEW 3-STORY, 23-UNIT APARTMENT WITH ROOF DECK OVER ONE LEVEL BASEMENT GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10146	19041-20000-46966	6610 N ENSIGN AVE	91606	2	180B173   463	2319019022	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Expired	05/08/2023 12:00:00 AM	ADDRESS	34.19057	-118.37163	PV1.  Install 11.02 kW DC / 8.8 kW AC roof mounted grid tied PV system and 9.8 kWh energy storage system.  (38) modules with 5.0 kW and 3.8 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10147	16041-10000-41426	3658 N BARHAM BLVD BLDG P	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.13899	-118.34141	PC FOR NEW PANELS, STACKED WASHERS & DRYERS IN CERTAIN APT. UNITS IN BUILDING P OF CAMPUS STYLE COMPLEX. THIS IS BUILDING 1/6(Add 1 laundry ckt to 39 units, and 1 microwave ckt to all 63 units in the building, total 102 new ckt in the building.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10148	15041-20000-23249	707 W WILSHIRE BLVD 50th Floor	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.04893	-118.2572	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 9,600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10149	19041-10001-23247	1615 S COLBY AVE	90025	11	126B149   171	4261013900	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM			PC Approved	10/30/2019 12:00:00 AM	ADDRESS	34.04458	-118.45269	change to an approved set, relocating of 4 EV chargers and updating voltage drop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10150	15041-20000-30346	5446 N SATSUMA AVE	91601	2	174B173  1277	2416014011	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM			Reviewed by Supervisor	10/16/2015 12:00:00 AM	ADDRESS	34.17004	-118.3674	PLANCHECK FOR POWER AND ENERGY.  CONVERT WAREHOUSE TO OFFICES AND STUDIO.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10151	11041-10000-10386	1114 S GAYLEY AVE	90024	5	132B149   105	4363023027	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.05987	-118.44596	CHANGE OF USE FROM EXISITING  PORTION OF RETAIL TO   RESTUARANT, T.I ON EXISITIN PORTION ( 15' X 78 ') OF RESTAURANT ; UPGRADE RESTOOMS, KITCHEN REMODEL, INT. FINISHES., NO ALCOHOLIC BEVERAGES WILL BE SERVED OR SOLD ON OR AROUND PREMISES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10152	12041-10000-08873	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	01/07/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	Install 18 receptacles, 12 luminaires, 6 data outlets, and one fire alarm device to existing system.  The plan was checked for energy complaince only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10153	17041-10001-15380	624 S GRAND AVE	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.04802	-118.25572	PC FOR REVISION TO APPROVED SET UNDER DELATA 4.SCOPE INCLUDES CHANGES TO PULL BOXES ON 18,24,30 FLOORS SIZING. CHANGES TO GROUNDING SIZE ON FEEDER SCHEDULE AND FEEDER ON SLD. THIS IS PLAN CHECK ONLY!!Plan check for power and Title 24.  Installation of four (4) new medium voltage switchgears for connection to a temp' backup genset.  Three new transformers and a new 480 V distribution panel for connection to existing loads.  New electrical room lighting.  Total area = 260 sq. ft.       Building permit #17016-10000-12057	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10154	15041-10000-26965	19600 S VERMONT AVE	90502	15	057B197    31	7351033009	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	33.85227	-118.2903	PC FOR POWER AND ENERGY. TI FOR FIRST TIME TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10155	16041-10000-31438	17555 W VENTURA BLVD	91316	5	171B129   344	2257008049	(Q)C4-1VL, (Q)P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.16199	-118.51602	Plan check for Title 24 only in existing space T.I. replace lighting fixtures wiring existing to remain. Total area: 6,613 sq ft. Note to Inspector: Please verify each enclosed space for multi-level control	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10156	12041-10000-29631	700 WORLD WAY Terminal 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	33.94286	-118.39982	TITLE 24 SIGN LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10157	10041-10000-17816	1006 E 28TH ST	90011	9	118-5A209 315	5128022009	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Apartment			09/17/2010 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.01717	-118.2574	CHANGE EXISTING 50 GUEST ROOMS TO 25  STUDIO UNITS AND WITH AN ADDITION TO EXISTING BUILDING ADD 24 STUDIO UNITS TO MAKE A TOTAL OF 49 UNITS.  EXISTING BUILDING IS A HISTORICAL BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10158	16041-10000-40169	1828 E CESAR E CHAVEZ AVE #605	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Info Complete	02/03/2017 12:00:00 AM	ADDRESS	34.05014	-118.21571	Plan check for power and energy Medical Office T.I. 3 Exam rooms #605 on 6th Floor. Total area: 1,746 sq ft.B# 16016-10000-27244	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10159	10041-10000-03938	13071 S KIYOT WAY	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/22/2010 12:00:00 AM	PIN	33.97159161	-118.42340103	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10160	11041-10000-06436	111 W PACIFIC COAST HWY	90744	15	036B205  1071	7421022036	[Q]C1.5-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	33.7913	-118.26364	T.I.  RETAIL SPACE BEING CONVERTED TO NEW 7-ELEVEN.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10161	19041-10000-33043	21550 W OXNARD ST Ste. 420	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Issued	08/22/2019 12:00:00 AM	ADDRESS	34.179	-118.60001	Tenant improvement to install interior partitions to (E) office in suite #420. Installing new lights. T-24 Energy only. Area: 928Sqr Ft.Building Permit: 19016-40000-25406	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10162	12041-20000-25778	23818 W TIARA ST	91367	3	177B089   734	2045016009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.17851	-118.64534	Photovoltaic system on roof of single family dwellling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10163	12041-10000-06967	11300 W OLYMPIC BLVD #710	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.03792	-118.44134	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE REMODEL TO SUITE 710.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10164	12041-10000-18680	5622 N VAN NUYS BLVD	91401	2	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.17276	-118.44836	(#5622)  TENANT IMPROVEMENT TO INTERIORS OF 1,500 SF COMMERCIAL SPACE;  EXISTING BATHROOM TO REMAIN.  Load is less than 400 Amps.  Plan Check Only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10165	14041-20000-32208	4626 N ATOLL AVE	91423	4	168B157   683	2360024038	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Expired	12/15/2016 12:00:00 AM	ADDRESS	34.15481	-118.42019	Roof mounted PV system with system size 7.5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10166	13041-10000-27837	541 S SPRING ST STE # 104	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.04657	-118.2507	NONSTRUCT INT T.I. - CHANGE OF USE FROM EX TWO RETAIL TENANT SPACES (#104 & 105) TO ONE RESTAURANT (#104) -plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10167	14041-10000-21449	21101 W SUPERIOR ST	91311	12	201B105   173	2746004041	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.24645	-118.59334	Remove HID light fixtures and replace with new fluorescent. T24. Area = 9716	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10168	13041-10000-26011	380 WORLD WAY #T52R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of 4 led sel-illuminated signs on the external walls of a the tenant space Fred Segal  on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the the two frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10169	14041-20000-30244	12125 W VANOWEN ST SUITE 2	91605	2	183B165   642	2321026029	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.19408	-118.39731	TI TO DENTAL OFFICE. PC FOR POWER AND ENERGY. HEALTH CARE. ART 517. EXISTING DENTAL. REMODEL WALLS AND CIRCUITS. NEW WIRING, EXISTING DISTRIBUTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10170	14041-20000-22455	4842 N QUEEN FLORENCE LANE	91364	3	168B113   119	2175016004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.1591	-118.56626	PV1Microinverter standard plan.Install roof-mounted solar array on SFD, interconnect with main panel.  System size: 9kW.(36) EnPhase M250 microinverters(36) Solar World SW275 pv modulesDerating main breaker to 150A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10171	10041-10001-04538	1630 N MAIN ST Bldg 15	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/11/2011 12:00:00 AM	PIN	34.06623967	-118.22749482	Installation of an exterior  50 KW Photovoltaic sytem.   The moudules are installed on the roof  of  buidling 15 as shown on the area plan.  The system includes a 50 KW -  3 phase Inverter, 13 strings of  13 modules each, one combiner box suitable for the connection of 24 strings, an AC disconnect switch, and one service disconnect switch.  The system is grid tied, but supplies no other load except the DWP pole mounted transformer.  <<<<<<<<<<<<<<<CHANGE TO EXISTING APPROVED SET OF PLANS.  # OF MODULES FROM 13 PER STRING TO 12 PER STRING.>>>>>>>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10172	18041-10000-29156	11357 W SHERMAN WAY	91352	2	183B173    94	2315022022	[T][Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.10	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.20136	-118.37876	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10173	19041-20000-41381	11845 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10174	10041-10001-22580	13720 W RIVERSIDE DR	91423	4	168B157   318	2269025002	C2-1, C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/13/2011 12:00:00 AM			PC Approved	04/13/2011 12:00:00 AM	ADDRESS	34.15674	-118.43273	REVISIONS TO APPROVED SET OF PLANS-DELTA 4 CHANGES)))))))))TI REMODEL OF (E) RETAIL SPACE - SPORTS AUTHORITY -INCLUDING DOORS, PARTITIONS, CEILING, FIXTURES, LIGHTING, MEP WORK; 46,432 SQ (BASEMENT TO 2ND FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10175	12041-10000-25411	2049 S CENTURY PARK EAST 40th;41st;-42nd Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	Ti on the 40, 41, and 42 floors of a highrise office Bldg. New panels, ckts, and lighting. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10176	15041-10001-28782	5715 S DENKER AVE	90062	8	108B193  1152	5003030036	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM			PC Approved	11/13/2015 12:00:00 AM	ADDRESS	33.99012	-118.3046	Expedited per customer request. (((PV1 for a residential site. Roof mounted solar system: (22) modules, (1) inverter 3.0 kw (1) load center: 125 amps.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10177	18041-20000-04865	10360 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.2587	-118.57962	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10178	14041-20000-02041	11100 W SANTA MONICA BLVD 14TH FL	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.04726	-118.44465	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. TOTAL SQRFT 14000. SCOPE OF WORK ON THE 14TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10179	16041-20000-23282	8462 W MCGROARTY ST	91040	7	204B189  1099	2560036012	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.25237	-118.31785	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW. STANDARD PLAN.THIS IS PLAN CHECK ONLY.PERMIT FEES PAID UNDER APPL NUM 16041-90000-15927	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10180	16041-10000-13793	7050 N TOPANGA CANYON BLVD	91303	3	183B101   272	2138002038	P-1VL-RIO, [Q]C1.5-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.19875	-118.60563	PC for outdoor lighting only. . Total affected area: 973	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10181	18041-20001-38365	533 E DOLORES ST	90744	15	036B209   221	7422025022	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	33.79446	-118.25702	expeditepv1install roof mounted pv system sized 7.6KW AC with battery back up interconnected with msp.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10182	17041-20000-43375	8521 N NEWCASTLE AVE	91325	12	192B125   231	2787003013	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.2254	-118.526	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.4 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10183	17041-10000-16765	705 S GAYLEY AVE 1-12	90024	5	135B149   456	4363007020	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			05/18/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.0654	-118.44812	PC FOR ENERGY AND POWER. New 5- story type , 12 UNITS APARTMENT BUILDING. SERVICE SIZE: 800AMP. TOTAL ARAE 14716 SQ FT.B # 14010-20000-04173	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10184	15041-20001-16287	936 S OLIVE ST UNIT 353	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #7 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10185	13041-10000-35744	8700 W BEVERLY BLVD 1F	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Closed	06/23/2017 12:00:00 AM	ADDRESS	34.07666	-118.3805	TI 1ST FLOOR. PC for POWER ENERGY GAMMA KNIFE TO MRI. adding 2 UPS as well. Plan checker to verify fees ***ARCHITECTURAL & STRUCTURAL ALTERATION AT THE FIRST FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10186	14041-10000-20836	11100 W RIVERSIDE DR	91602	4	165B173    87	2423011005	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			08/01/2014 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.15214	-118.37265	FULL PLAN CHECK FOR NEW 4 STORY 51 UNIT APARTMENT BUILDING.  New 1600 amp service, 12 typical units, title 24 forms to be submitted later (total area = 40,000 sq ft).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10187	14041-10000-22994	1162 S MAIN ST	90015	14	126A209   295	5139016009	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.03757	-118.25908	T24, replace HID light fixtures with new flurescent fixtures. Total area 2268 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10188	18041-10000-41212	5801 S CENTRAL AVE	90011	9	108B209  1319	5103015033	MR1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.20	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	33.99004	-118.25665	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10189	14041-20000-25301	10739 W STALLION RANCH ROAD	91040	7	204B177   260	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Expired	04/12/2017 12:00:00 AM	ADDRESS	34.25715	-118.36484	PV1INSTALL GROUND MOUNT PV SYSTEM SIZED 18KW INTERCONNECTED WITH MSP.(80) CANADIAN SOLAR 250 MODULES(80) ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10190	17041-20000-15353	9111 N DE SOTO AVE	91311	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Info Complete	05/09/2017 12:00:00 AM	ADDRESS	34.23591	-118.58873	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10191	16041-20000-04189	11002 W HUSTON ST	91601	2	168B173   144	2353019021	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.15998	-118.37077	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 620 sq. ft.Note: Electrical permit has been pulled under 16041-20000-03171. Building permit has been pulled under 15016-20000-10539	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10192	13041-10001-31899	16407 W HAMLIN ST	91406	6	180B137   507	2231003028	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.18854	-118.49054	EXPEDITED RSES PER APPLICANT REQUEST. (((PV1.  Install 5.25 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverters: Enphase M215.  21 modules: Canadian Solar CS6P-250P)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10193	17041-10000-00941	2023 S UNION AVE	90007	1	124-5A201  60	5124002021	[Q]C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.03665	-118.28252	Energy plan check for (2) new office in the first floor and new outlets on second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10194	19041-20000-43805	10265 N HADDON AVE	91331	7	204B157   511	2646023038	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/14/2019 12:00:00 AM	ADDRESS	34.25673	-118.42437	NEW PV USING CENTRAL INVERTER WITH POWER OPTIMIZERS, (24) PV MODULES, (1) SUB PANEL, AND (1) 5.8 KVA BATTERY. TOTAL PV SYSTEM SIZE IS 7.6 KW AC/7.56 KW DC. ESS SIZE IS 13.5 KWH	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10195	13041-20000-29978	13038 W SAN VICENTE BLVD	90049	11	129B137   498	4264001004	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.04835	-118.49101	NEW 800A SERVICE. NEW SHELL. LIGHTS AND RECEPTACLE FOR HOUSE LOADS. MULTI TENENT RETAIL. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10196	16041-10000-02223	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			Corrections Issued	01/21/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI on (E) LAWA (tom Bradley Intl) TBIT IN-TRANSIT Terminal corridor project. Install new lighting fixtures and exit signs. PC for Energy only, 1,283 sq. ft***Permit pulled under 15041-10001-19731	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10197	10041-20000-19857	9189 N DE GARMO AVE	91352	6	198B173   125	2408034042	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.23604	-118.37603	Plan check for new 5000A service and service equipment. Loads are existing. Site in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10198	13041-10001-28820	6352 N RIVERTON AVE	91606	2	180B177   279	2414009001	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.18637	-118.36578	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS UNGROUNDED. SYSTEM SIZE: 4.5 kW DC.(18) TRINA SOLAR # TSM-250(1) SOLAREDGE # SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10199	13041-20000-00691	4170 S DEL REY AVE	90292	11	105B153    13	4230005033	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/10/2013 12:00:00 AM			PC Approved	01/10/2013 12:00:00 AM	ADDRESS	33.98745	-118.44398	Plan check for energy. Outdoor parking lot. 58213 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10200	14041-10000-02412	1188 S SAN PEDRO ST STE M	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	PIN	34.03375994	-118.25280059	Remove HID light fixtures and replace with new fluorescent fixtures in a retail space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10201	18041-20000-32618	20829 W BERMUDA ST	91311	12	207B109   207	2706027027	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.26555	-118.58764	Plan check for PV roof mounted system, system size: 8.96kW with 28 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10202	13041-10000-22281	20306 W CORALINE CIR	91311	12	207B113   142	2707018012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.2629	-118.57598	PV1 12.25KWdc 240V XFRM negatively grounded. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: FRONIUS IG PLUS V 10-1UNI] [( 50) MOD: Trina {TSM-245PC05.18}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10203	18041-10000-19696	4150 W MARATHON ST	90029	13	141B197   347	5539021005	RD1.5-1XL	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Apartment			05/25/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.08452	-118.29088	PLANCHECK FOR POWER ONLY. ADDITION OF (93)  DRYER UNITS AND LAUNDRY CIRCUITS TO EXISTING APARTMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10204	17041-10000-08427	3819 S CLARINGTON AVE	90232	5	120B165  1303	4208002002	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Issued	03/16/2017 12:00:00 AM	ADDRESS	34.02199	-118.40007	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 6,375 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10205	13041-10001-27910	5475 N MAEMURRAY DR	90041	14	165A227    17	5669008004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.14708	-118.19899	Expedited plan check per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10206	18041-10001-22159	360 E 2ND ST	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM			PC Approved	06/26/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	Change to approved set by modifying the lighting plan. All changes under delta-1 only.(((TENANT IMPROVEMENT TO FIRST FLOOR OF AN EXISTING OFFICE.  TITLE 24 ENERGY ONLY. 1563 Sqr Ft.BUILDING PERMIT # 18016-30000-18786)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10207	17041-30000-07275	6923 N ROYER AVE	91307	12	183B097   707	2026014004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.19532	-118.62873	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (38) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10208	16041-10001-41662	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM			PC Approved	12/09/2016 12:00:00 AM	ADDRESS	34.04338	-118.26581	Changes to approved set of plans per inspector request. Existing building (Staples Center) Recheck on emergy lighting system, title 24.  Total area: 3,632 sq ft.*New Changes Delta 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10209	11041-10000-19202	26640 S WESTERN AVE	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	09/20/2011 12:00:00 AM	ADDRESS	33.78015	-118.30862	T.I. TO AN EXISTING SPA.  PLAN CHECK ONLY FOR ENERGY (NO EMERGENCY LIGHTING EXISTING OR TO BE INSTALLED PER ENGINEER)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10210	12041-20000-22175	6000 N WOODMAN AVE	91401	2	177B157   849	2330028017	[Q]C1.5-1VL, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02, 1245.00	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.17962	-118.43105	plan check for energy and power for restaurant. Change of use from office to restaurant. Occupant load is 130 per applicant. Sofi Restaurant. 2962 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10211	15041-10003-14886	1200 S BROADWAY	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	34.03792	-118.26026	03/10/2017 Changes to an approved set of plans. Changes include Change manufacture for switch gear sections and overcurrent devices from Eaton to Siemens. Changes apply to delta 21 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10212	19041-10000-45828	4112 W SLAUSON AVE	90043	8	108B181   272	4019002006	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	33.98874	-118.34674	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10213	14041-20000-15147	11070 N O'MELVENY AVE	91340	7	210B153   569	2616013038	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.2717	-118.44106	PV1.  Install 5 kW rooftop-mounted, utility-interactive PV systtem.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10214	13041-10002-30473	1891 N ACADEMY DR	90026	1	141B213    20	5415005902	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.08305	-118.2417	Changes to approved set. Addition of jockey and fire pump on single diagram. Changes clouded as delta 1. bolting closed main service and removing disconnect. verify with DWP if ESR allows connection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10215	13041-20001-02690	4460 W WILSHIRE BLVD 705	90010	4	132B189    45	5090019***	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			02/07/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.06172	-118.32623	"Modification to approved set of plans.  Plans were not originally provided with Service Load Calcs or single-line diagram.  Plan check is only for adding circuit 5B and revise loads on 1A, 3A, 9 AND 11.              <<<<Inspector has requested full plan check. Condo unit. Unit 705. Load less than 400A. Permit for lighting circuits has already been pulled...permit fee for this application is under ""inspection"" fee period.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10216	16041-20000-24574	18111 W TOPHAM ST	91335	3	177B125  1043	2124015050	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.18075	-118.52791	PV1. ROOFMOUNTED SOLAR SYSTEM. 3.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10217	18041-10000-34184	1100 S GLENDON AVE	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	Energy plan check for INTERIOR OFFICE TI. Scope includes new lighting and equipment with a total area of 7309-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10218	18041-20001-06479	11970 W VENTURA BLVD	91604	2	162B169   144	2369016034	C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM			PC Approved	08/07/2018 12:00:00 AM	PIN	34.14328811	-118.39283103	08-07-2018 Changes to an approved set of plan, changes include update new lighting layout, all changes has been clouded as delta 1. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10219	18041-10000-09039	2423 E 23RD ST	90058	14	118-5A217 227	5168013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.01738	-118.22944	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10220	19041-10000-48062	14414 W PLUMMER ST	91402	6	198B149    83	2644027025	RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.2425	-118.44691	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10221	19041-20000-27602	4810 N VINELAND AVE	91601	2	168B173   466	2421014003	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	03/09/2021 12:00:00 AM	ADDRESS	34.15791	-118.37008	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first time tenant/change of use from retail to catering shop/retail. Work includes a 600 amp service and a total lighting area of 2,722 sq. ft.Note: Building application has been generated under 19016-10000-15825	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10222	19041-10000-10427	1040 N LAS PALMAS AVE STG 4	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10223	11041-20000-20361	4832 N TUJUNGA AVE	91601	2	168B173   228	2353023019	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	09/23/2011 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.1586	-118.37883	bathroom t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10224	19041-10000-35391	6101 N MAURY AVE	91367	3	177B085   253	2032019021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.18154	-118.66112	NEW ROOF MOUNTED 20.44KW PV SYSTEM WITH (56) PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10225	12041-10003-16076	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM			PC Approved	12/22/2014 12:00:00 AM	ADDRESS	34.10158	-118.3062	revisions to lighting system permitted under 12041-10001-16076Plan check for energy and power. Restaurant. Single story commercial. 120 occupants per applicant. 4653 sqft. Parasolnine Thai Restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10226	18041-10000-45268	660 S FIGUEROA ST #1780	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Corrections Issued	11/28/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	Energy plan check for an office T.I located on the 17th Floor of a high rise building. Scope inlcude new lighting and equipment with a total area of 1800-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10227	15041-20001-18373	19953 W RINALDI ST	91326	12	210B113   187	2701040018	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	ADDRESS	34.2758	-118.56956	11/16/15:  PC for Delta-1 only (changed on lighting control)((Energy plan check for a restaurant (Pieology ) T.I ; Scope include new equipment, receptacles and lighting.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10228	19041-10000-11865	1040 N LAS PALMAS AVE STAGE 9	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 9	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10229	19041-20000-03279	10651 N OVERMAN AVE	91311	12	207B109   376	2707019015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.26418	-118.57821	addition of (1) sonen eco 16 (8KW) battery to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10230	18041-20000-44058	12415 W JEFFERSON BLVD	90066	11	105B161   997	4211003066	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	PIN	33.9810359	-118.41038332	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,391 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10231	10041-20000-22289	15060 W VENTURA BLVD #350	91403	5	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	12/20/2010 12:00:00 AM	ADDRESS	34.15287	-118.46147	Plan check T24 Energy general & emergency lighting TI for suite #350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10232	19041-20000-06892	555 S FLOWER ST Ste 4250	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI to (E) commercial highrise office space.  Plan check for energy.  Exit signs (E) to remain per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10233	11041-20000-21285	6039 N DE SOTO AVE	91367	3	177B105    63	2149005032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	12/01/2011 12:00:00 AM	ADDRESS	34.18005	-118.5908	Emergency lighting and exit signsCHANG OF USE TO INDOOR TRAMPOLINE PARK(A-3 OCC) W/WOOD PLATFORMS & ADD 1,785 SQ FT MEZZANINE.SUPPLEMENT TO 11016-20000-14803	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10234	14041-20000-28390	7815 N CHIMINEAS AVE	91335	12	189B125   686	2102017097	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.21241	-118.52876	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(12) SUNPOWER E20 MODULES(1) POWER ONE 3.8 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10235	14041-20000-26075	16506 W KINGSBURY ST	91344	12	207B137   519	2679004002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.26369	-118.49145	PV1.  Install 8.8 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10236	12041-20001-21635	8719 N VARIEL AVE	91304	12	195B105   215	2779016005	(T)R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34, 1134.21	Electrical	Electrical	Apartment			08/08/2014 12:00:00 AM			PC Approved	08/08/2014 12:00:00 AM	ADDRESS	34.22877	-118.5932	Modifications to approved set.  Change of service/metering equipment.(((New 19 units appartment BLDG. EPC is for power & energy. (modification for a separate fire alarm system was filed))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10237	17041-10000-08646	17640 W BURBANK BLVD	91316	5	174B129   844	2254037003	C2-1VLD-RIO, P-1VLD-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.17207	-118.51766	PC for title 24, indoor. Replacing on one for one basis fluorescent fixutrs to new LED ones. Area is 7824 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10238	18041-20000-06392	18240 W VALLEY VISTA BLVD	91356	3	168B125   267	2181032003	R1-1	South Valley	Encino - Tarzana	Tarzana		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Issued	02/21/2018 12:00:00 AM	ADDRESS	34.15836	-118.53031	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWAC and consists of (2) inverters, (39) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10239	12041-20000-11692	709 N VIRGIL AVE	90029	13	141B197   436	5539020030	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	ADDRESS	34.08399	-118.28701	Plan check only / energy for existing permit 12041-20000-10515 ( Addition of 6 recepticles, 3 recessed lights and existing switches. FIRE DAMAGE. ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10240	18041-20000-03026	2805 S MCCONNELL DR	90064	5	126B165   650	4308014010	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.04091	-118.40132	install one tesla powerwall 5kw to an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10241	15041-10000-20098	6060 W WILSHIRE BLVD	90036	4	135B177   526	5086009014	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.06273	-118.36103	PC FOR  ENERGY. RENOVATION OF PORTE COCHERE. PETERSEN AUTOMOTIVE MUSUIM, PARKING AREA. TOTAL AREA 11810 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10242	10041-20000-01929	3378 W SAN FERNANDO ROAD	90065	13	153B209   129	5458003018	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	02/09/2010 12:00:00 AM		Permit Finaled	02/18/2010 12:00:00 AM	ADDRESS	34.11746	-118.25107	T.I. WORK INSIDE WAREHOUSE IN OFFICE AREA. THIS PLAN CHECK IS ONLY FOR TITLE 24 ENERGY ONLY.   EXISTING PERMIT 10041-20000-00685.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10243	19041-10000-14155	17950 W PARTHENIA ST	91325	12	195B129   429	2787001019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.22845	-118.52472	[e-plan] REVISION TO EXISTING PERMIT NO. 18041-10000-15377; Adding Generac automatic transfer switch (150A with Load Center) & DC disconnect (30A) listed with mechanical interlock	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10244	15041-20002-25663	6316 N TOPANGA CANYON BLVD B-2140	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	12/09/15 Changes to an approved set of plans. Changes included the addition of a new 75 kVA transformer between panel 2140H and 2140AC.*****Previous Work Description*****Plan check for power and energy 1st time tenant Topanga Mall. Total indoor area: 7,586 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10245	19041-10000-23769	467 S LA BREA AVE	90036	4	135B181   576	5508006014	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Re-Activate Permit	10/04/2019 12:00:00 AM	ADDRESS	34.06505	-118.34421	PC FOR T-24 ONLY , TI TO EXISTING RETAIL. SCOPE OF WORK AREA IS 1844SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10246	18041-20001-20864	6222 W WILSHIRE BLVD 400	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.06309	-118.36418	11/08/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.*****Previous Work Description*****PLAN CHECK FOR ENERGY (T24) ONLY, TENANT IMRPOVEMENT TO (E) OFFICE BUILDING STE.400. TOATL AREA: 12,165 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10247	19041-20000-06335	2301 S CLOVERDALE AVE	90016	10	123B177   142	5063008066	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			02/21/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	04/17/2020 12:00:00 AM	ADDRESS	34.03671	-118.35592	PC FOR NEW FIRE ALARM SYSTEM IN NEW 4 STORY APARTMENT BUILDING, 53 FA DEVICES AND 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10248	19041-30000-31516	809 S MANSFIELD AVE	90036	4	132B181   272	5084002014	R3-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.06017	-118.34153	PV1. INSTALL 6.175 KW DC (19) MODULES WITH OPTIMIZERS (TS4-R-S) ON EXISTING 200 AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10249	19041-10000-28603	9825 N WOODLEY AVE	91343	12	201B137   235	2677023004	A2-1, RE9-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.24937	-118.48514	Replace fluorescent troffers with new LED retrofit kits and exterior metal halide fixtures with new LED fixtures ( Indoor and Outdoor)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10250	18041-20000-29806	1068 W 251ST ST	90710	15	036B197   174	7413015030	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	33.79659	-118.29514	Plan check for Title 24 only in existing space warehouse T.I. new lighitng and receptacles. Total area: 3600  sq ft. B#18016-10000-25171	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10251	14041-10000-04634	2049 S CENTURY PARK EAST 40TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Issued	02/24/2014 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 40-42ND FLOOR. 1079 SQFT. NO WORK ON EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10252	19041-10000-00179	1454 N SAN YSIDRO DR	90210	5	147B157   224	4355004038	RE20-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM			Reviewed by Supervisor	01/24/2019 12:00:00 AM	ADDRESS	34.09845	-118.42259	PV1, INSTALLING 17.395KWDC AND 11.76KWAC ROOF MOUNTED SOLAR SYSTEM, CONSIST OF 49 MODULES (MONO HS-355-TD-AN3) AND 49 MICROINVERTERS (ENPHASE IQ7-PLUS-72-2-US) WITH (1) NEW COMBINER BOX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10253	15041-20000-10759	13009 N MESA VERDE WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.30852	-118.4072	Plan check for PV1 roof mounted 3.6kW system with 1 inverter(ABB PVI-3.6-OUTD-US-Z-A) and 17 modules(Kyocera KU2606XPA)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10254	18041-10000-22392	767 S ALAMEDA ST Room B-14	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM			PC Info Complete	06/26/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	TI IN THE EXISTING STORAGE ROOM B-14. INSTALLING LIGHTS AND RECEPTACLES.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10255	10041-10000-06027	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	10/06/2010 12:00:00 AM	ADDRESS	34.18686	-118.37207	Changes from prveviously approved plans (Target store).  Add new circuits, panel, transformer, motors, lighting, and walk-in coolers.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10256	12041-20000-23621	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			Corrections Issued	10/03/2012 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for energy only. 2200SF. office building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10257	15041-10000-43434	5577 W ADAMS BLVD	90016	10	123B177   997	5048001061	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.03263	-118.36463	PC for energy only to an existing commercial building (Green Line Sandwich shop). Adding new lighting and power. Total sq ft =1038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10258	14041-10000-17832	301 N MCFARLAND AVE	90744	15	027B209    18	7424016911	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Special Equipment			07/01/2014 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	33.77348	-118.25297	Plan check for power only.  Remove and replace ATS, generator, VFDs, pumps, and motors in existing industrial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10259	14041-20001-09055	12746 W JEFFERSON BLVD #1100	90094	11	102B161  1229	4211033053		West Los Angeles				2756.01	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Changes to approved set.  Changes to lighting control system.  2013 Title 24 sheets are used (previously 2008).  Removal of track lighting and addition of lighting for kitchen hood.  Addition of garage door opener.  Total connected load increased.  All changes are clouded.*****Previous Work Description*****First time tenant (Whole Foods Supermarket) for the core ans shell building. Install panels, transformers, branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10260	16041-10001-04954	2700 N VERMONT AVE	90027	4	153B193   686	5593002913	OS-1XL	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	34.11803	-118.29221	PC only under permit 16041-10000-04954. Install EM. light for hardscape path of egress in the outdoor area. Total area 30,465 sq.ft. PC for Emergency lighting and Energy only.<<REWORK CIRCUITS IN (E) PANEL. INSTALL (2) NEW PANELS.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10261	14041-20000-18316	4529 E BOWMAN BLVD	90032	14	141A231    58	5213029024	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Expired	08/12/2016 12:00:00 AM	ADDRESS	34.08204	-118.18517	PV1.  Install 4.410 kW roof-mounted, utility-interactive PV system over detached garage.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10262	19041-10000-23249	7141 N REMMET AVE	91303	3	183B105   238	2111026900	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.20033	-118.60041	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10263	10041-20000-00990	12226 W CANTURA ST	91604	2	162B165   378	2369005026	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2010 12:00:00 AM			PC Approved	01/20/2010 12:00:00 AM	ADDRESS	34.14215	-118.39969	Residential photovoltaic solar system using micro-inverter modules. Permit already issued under PCIS # 09041-20000-15550.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10264	15041-20000-07338	10950 W BLOOMFIELD ST 1-49	91602	4	165B173   468	2423020125	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			03/12/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.14907	-118.36968	Installation of new 151 device fire alarm system in new3 story 49 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10265	13041-20000-25181	7710 N HASKELL AVE	91406	6	189B141   263	2206012023	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	ADDRESS	34.21064	-118.47474	T24 FOR NEW AREA OF EXISTING MANUFACTURING BUIDLING. SCOPE OF WORK IN PRODUCTION AND LOUNGE AREAS. TOTAL COMBINE OUTDOOR AND INDOOR SQRFT 3806	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10266	16041-10000-34554	700 S MAIN ST	90014	14	127-5A211 142	5145001003	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.04365	-118.25151	PC for energy only. Remove HID fixture and replace with new LED fixture. Total sqft = 24700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10267	17041-10000-38008	13762 W BERG ST	91342	7	225B153   196	2510021022	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.31543	-118.4329	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.075KWdc / 11.2KWac.(35)AC MODULES-SUNPOWER SPR-X21-345-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10268	12041-20000-13033	120 N SANTA FE AVE	90012	14	129A217    53	5173013016	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM			PC Info Complete	08/07/2012 12:00:00 AM	ADDRESS	34.04899	-118.23231	Upgrade to 600A service for existing building.  Plan check power.  The electrical engineer submitted a letter from the on site property manegement company indicating that all tenants are allow access to the service disconnecting means during normal business hours.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10269	13041-20000-09117	4124 S GRAND VIEW BLVD	90066	11	111B157   802	4232004013	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Apartment			04/09/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	33.99838	-118.42607	solar 7.8 kw apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10270	16041-20000-07770	4578 N VAN NUYS BLVD	91403	4	168A151   154	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.15489	-118.44849	Plan check for power and energy T.I. newly connected load exceed 400A. Exising panels and distribution board and service. Total area: 10,529 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10271	17041-10000-15139	15301 W VENTURA BLVD STE P-5	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.15411	-118.46654	"PLAN CHECK FOR POWER AND ENERGY.  TI TO (E) RESTAURANT SHELL WITH COVERED OUTDOOR DINING.  ""A"" OCCUPANCY LOAD > 100.  SUBPANELS TO REMAIN EXISTING.  NO CHANGE OF USE.  TOTAL AREA = 8499 SQ. FT.      BUILDING PERMIT #17016-10000-09902"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10272	15041-10000-05585	9025 N SUNLAND BLVD	91352	6	195B173    72	2408005033	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.23307	-118.36721	T24 ONLY.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 10879 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10273	17041-10000-10041	5259 W PICO BLVD	90019	10	129B181   879	5085036021	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.04842	-118.353	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1971 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10274	17041-10000-10505	2697-2701 W JAMES M. WOOD BLVD	90006	1	132A201   169	5077025015	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			03/31/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	34.05606	-118.28673	PC FOR POWER AND ENERGY FOR A new 4 story 33 units apartment over 2 level sub parking.SERVICE SIZE 1200A 3 PHASE 208/120VTOTAL AFFECTED AREA OF 30442 SQ.FT.FIRE ALARM VARIANCE WAS FILED WITH THE DEPARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10275	19041-10000-06682	818 E 3RD ST UNIT BA	90013	14	129A215   311	5163015016	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.04571	-118.23563	PC T-24 only for Tenant improvement to existing restaurant. area 2960 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10276	17041-20000-32783	19208 W BRIARFIELD WAY	91356	3	162B117   196	2177047006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.141	-118.55235	Plan check for the addition of (2) Tesla Powerwall to an existing PV1 roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10277	19041-30000-52104	350 S GRAND AVE	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	02/03/2020 12:00:00 AM		Issued	02/03/2020 12:00:00 AM	ADDRESS	34.05173	-118.2522	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFCETED AREA IS 18,425 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10278	17041-10000-13346	15000 W KESWICK ST A-B	91405	6	186B149    15	2209038043	[T][Q]CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM			Reviewed by Supervisor	05/17/2017 12:00:00 AM	ADDRESS	34.21008	-118.45905	Plan check cancel by applicant PC FOR POWER AND ENERGY. NEW BUILDING WITH OFFICE & WHAREHOUSE SPACE,  AND  PARKING AREA. 600AMP SERVICE. TOTAL AREA  9989 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10279	17041-10000-46036			15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM			PC Approved	12/22/2017 12:00:00 AM	PIN	33.85469499	-118.30733496	PLAN CHECK FOR T24 ONLY FOR TI(REWORK (E) WAREHOUSE RESTROOMS AND ADD ADDITIONAL FIXTURES). TOTAL AFFECTED AREA = 1790 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10280	12041-20000-27445	2054 W PANAMINT DR	90065	14	151-5A219 218	5462030013	RA-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.10892	-118.2254	New 9.8kw rooftop mounted photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10281	19041-10000-00338	7224 N ATOLL AVE	91605	2	183B157    41	2327003004	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.20191	-118.4209	Energy plan check for removing HID fixtures and replacing with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10282	17041-10000-34982	6003 N WHITNALL HWY	91606	11	177B173  1139	2414005011	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Mar Vista		1231.04	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Issued	09/29/2017 12:00:00 AM	ADDRESS	34.17969	-118.36682	REPLACE HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10283	09041-10002-15014	1500 N VINE ST	90028	13	147A189    27	5546026034	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM			PC Approved	06/28/2010 12:00:00 AM	ADDRESS	34.0983	-118.32646	Modification delta 1 for T-24 plan check previously approved, to show the installation of 13 pendent lights.  No additional permit to be issued.  Checked under 2005 Standard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10284	11041-10000-26403	350 S OXFORD AVE	90020	4	135B193   393	5503004022	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2118.01	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.06744	-118.30769	Plan check for new fire alarm system for existing 2 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10285	15041-20000-16088	1864 W JEFFERSON BLVD	90018	8	120B193   713	5041005039	[Q]C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.02543	-118.31082	Title 24 plan check only.  Total area = 2,323 sq. ft. (indoor) + 6,485 sq. ft. (outdoor) Renovation and addition to commercial lowrise retail building with 400 A service.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10286	13041-10000-27887	19626 W ANADALE DR	91356	3	162B117   200	2180013004	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.14096	-118.56138	PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 5.25kW. TRANSFORMERLESS, UNGROUNDED.2 STORY. NON STANDARD PLAN.(21) TRINA SOLAR # TSM-250PA05.18(1) POWER ONE # AURORA PVI 3.6-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10287	18041-20000-04920	618 S VAN NESS AVE	90005	4	135B189   927	5504018011	RD3-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	03/01/2021 12:00:00 AM	ADDRESS	34.06245	-118.31518	Two 4-story 6-unit apartment buildings with common 600A 208Y/120V 3ph-4w service. Building 2 of 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10288	19041-10001-38970	13821 N KISMET AVE	91342	7	228B153   665	2503021057	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.3228	-118.43597	change of an approved set, change includes changing the mounting brackets only. original scope:Plan check for a 5.0KW AC / 6.0KW DC PV1 roof mounted system. Scope includes (1) inverter and (18) modules interconnecting through the main service panal.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10289	10041-20000-09505	13824 W VENTURA BLVD #A	91423	5	165B153   601	2266018007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1411.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.14824	-118.43394	PLAN CHECK POWER AND ENERGY CONVERT OFFICE SPACE TO TAKE-OUT RESTAURANT AND NEW 600 A SERVICE FOR THREE UNIT BUILDING. FIRST TIME TENANT. ALL OTHER TENANTS ARE NOT OCCUPIED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10290	11041-10001-24378	948 E LAKE ST BLDG 4-2	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/23/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.001	-118.46101	Lincoln Place Apartment Building Project.  New 2-story apt. building with 7 units.  (((((((((((((((((((((((((((((((((((((  Addition of 3 E.V chargers. M.Z  ))))))))))))))))))))))))))	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10291	14041-10000-24358	4605 N LANKERSHIM BLVD #300/330	91602	2	168B173   921	2421028013	C2-2	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.15405	-118.36832	Plan check for energy only. T24. No change in occupancy. Tenant improvement of offices. high rise. 2919 sq. ft. Emergency lighting. Suite #300/330, 3rd floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10292	16041-10011-01886	700-800 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Approved	08/31/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 43 ON PLANS. ADDITION OF CIRCUITS AND UPDATED  LIGHTING PLAN TO MATCH FLOOR PLANS .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10293	12041-20000-29834	11611 W SAN VICENTE BLVD	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.0541	-118.46261	Relocate an existing fire alarm control panel in an existing commercial building.  All devices are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10294	14041-10000-09801	711 S HOPE ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Issued	05/15/2014 12:00:00 AM	ADDRESS	34.04757	-118.25858	remodel hotel lobby onlyplan cgk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10295	13041-10000-32033	12022 W RIALTO ST	91352	6	192B165   295	2633011005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			Verifications in Progress	01/31/2014 12:00:00 AM	ADDRESS	34.22421	-118.39429	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING WITH (E) 125A  MAIN. SYSTEM SIZE IS 3 kW DC WITH (12) MODULES RENESOLA JC250M-24/BB IN 1 STRING, AND (1) SOLAR EDGE INVERTER SB3800A-US WITH OPTIMIZERS OP250-LV ON NON-STANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10296	14041-20000-06259	12180 W MILLENNIUM EAST	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	PLAN CHECK FOR OUTDOOR LIGHTING FOR PLAYA VISTA. THIS AREA IS IN A METHANE ZONE REQUIRES FULL PLAN REVIEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10297	17041-10001-11076	189 S THE GROVE DR H-4	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	11/22/2022 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES INCLUDE UPSIZING TRANSFORMER AND SUBFEEDS. UPDATED SINGLE LINE AND FLOOR PLANS. NO LIGHTING CHANGES. PERMIT FOR ADDED WORK TO BE ISSUED UNDER THIS PERMIT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10298	18041-10000-26934	6848 W SUNSET BLVD	90028	4	147B181   686	5548015003	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.0978	-118.34025	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10299	15041-10000-38105	727 W ANAHEIM ST	90744	15	030B205   391	7416021037	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	33.7797	-118.27084	T-24, PC for energy only. Ti to a commercial building (Fast Auto Lons). Installing new lighting and receptacles. Sq ft =558	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10300	17041-20001-00676	23239 W DOLOROSA ST	91367	3	174B093   588	2044001040	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	02/15/2017 12:00:00 AM	ADDRESS	34.17021	-118.63358	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.3 kWac and consists of (51) modules, (51) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10301	12041-10000-23264	3216 N GLENDALE BLVD	90039	13	154-5A207 228	5436025002	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	05/22/2013 12:00:00 AM	ADDRESS	34.11787	-118.26061	Change of use from retail to restaurant. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10302	08041-10001-05945	4822 W ELMWOOD AVE	90004	4	138B193   116	5522030017	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			02/17/2010 12:00:00 AM	06/18/2010 12:00:00 AM		Permit Finaled	04/15/2011 12:00:00 AM	ADDRESS	34.07803	-118.31211	New 18-unit 4-story apartment building + subterranean garage. 120/208 3ph 4W 800A Service.   Changes from previous approved plans.  Changes include loads. No change in lighting.   Plan check for power only.  Note: Approved plans submitted for reference.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10303	14041-20000-33018	826 W 43RD ST	90037	9	114B197  1094	5019007013	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.00539	-118.28822	pv1install roof mounted pv system sized 3.6kw interconnected with msp.(17) hyundai heavy his m250 modules(17) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10304	17041-20004-44997	327 N CHESTNUT AVE	90042	14	153A233    90	5493031004	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.11489	-118.1752	08-16-2018 Changes to approved set of plans.  Relocation of (1) PV module.  $0 permit fee due to California State Senate Bill 1222 as amended and extended by State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10305	10041-10000-00692	8700 W BEVERLY BLVD Spielberg-Bldg	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM			Reviewed by Supervisor	01/27/2010 12:00:00 AM	ADDRESS	34.07666	-118.3805	Plan check for installation of new emergency sub-panel feeding from existing emergency generator.  New sub-panel is in Steven Spielberg Bldg at Cedars Sinai Medical Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10306	17041-20000-41228	10033 N CASABA AVE	91311	12	204B113   579	2741019025	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.25281	-118.57618	pv1install roof mounted pv system sized 12.6kw intercvonnected with msp.Variance provided to allow 120% rule on center-fed panel per TIA #14-12.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10307	11041-10000-00104	3655 S GRAND AVE	90007	9	118-5A203 278	5122023028	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.01726	-118.27819	MONUMENT SIGN TO DISPLAY VENDORSSIGNS PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10308	10041-20000-10434	1025 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM	10/15/2010 12:00:00 AM		Permit Finaled	08/01/2011 12:00:00 AM	PIN	34.02400284	-118.2895744	TI IN USC COMPUTER LAB ROOM 206 AND 208. THIS P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10309	11041-10001-21198	10000 W PICO BLVD BLDG 2	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00, 2691.00, 2695.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.05211	-118.40654	Delta 4 revision to approved plans. Changes to lighting, addtional ckts added, relocate ckts, and review methane mitigation. BLDG. NO. 2 (Womens room section inc. outside lighting) OF POOL HOUSE AT THE HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDG. NO. 1, 2, 3, & 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10310	14041-10000-11113	14313 W RUNNYMEDE ST	91405	2	186B153   219	2215023026	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.20585	-118.44501	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10311	19041-20000-52128	2000 S AVENUE OF THE STARS Suite 900S	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	09/21/2021 12:00:00 AM	ADDRESS	34.05868	-118.41546	Distribution, power, and lighting for commercial tenant space in highrise building.  Plan check for energy and poewr.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10312	15041-10001-02099	1000 S HOPE ST	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM			PC Info Complete	03/13/2015 12:00:00 AM	ADDRESS	34.04346	-118.2617	CHANGED TO APPROVED SET, MODIFIED FAULT CURRENT PER INSPECTION REQUEST. installation of transformers and panelboards.permitted under original plan check application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10313	16041-30000-17321	4025 W SANTA ROSALIA DR	90008	10	117B181   793	5032009014	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01244	-118.34293	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10314	15041-10000-28391	13841 W PADDOCK ST	91342	7	228B153   568	2503007024	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.31775	-118.43524	PV1INSTALL ROOF MOUNTED PV SYSTEM (ACM) SYSTEM SIZE 5.7KW INTERCONNECTED WITH MSP.(20) LG ELECTRONICS LG300N1C-B3(20) LG ELECTRONICS LM305UE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10315	13041-10000-03123	6501 N FALLBROOK AVE	91307	3	180B097   471	2038040016	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.1881	-118.62368	PLAN CHECK FOR POWER AND ENERGY. ELECTRICAL WORK IS FOR NEW OLIVE GARDEN RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10316	16041-20000-32382	8902 N WOODMAN AVE	91331	6	195B153   475	2640016010	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.23142	-118.43728	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from medical to pharmacy on the 1st floor. Total lighting area = 1,730 sq. ft.Note: Building application has been generated under 16016-20000-13429	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10317	13041-10002-36293	3521 S MOORE ST	90066	11	114B153  1113	4245007019	R1-1-HPOZ	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	ADDRESS	34.00608	-118.44499	Plan check only. Removal of 8 modules and corresponding changes. No WEEBS allowed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10318	10041-10000-08562	1710 E 111TH ST	90059	15	088-5A213 472	6069003003	MR1-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM			Verifications in Progress	04/14/2011 12:00:00 AM	ADDRESS	33.93494	-118.24244	CORE AND SHELL FOR A COMMERCIAL BUILDING. PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10319	15041-30001-42267	15721 W MILBANK ST	91436	5	168B141   466	2261009023	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.15727	-118.47575	Expedite fee only.     Addition of new roof mounted solar PV array to existing roof mounted solar PV array on existing single family dwelling.  Total system size = 7.8 kWac (3.8 kWac new).  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10320	19041-20001-52389	2300 S PURDUE AVE	90064	11	123B153   177	4260023007	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	08/21/2020 12:00:00 AM	ADDRESS	34.03534	-118.44153	PV3.  Install 106.65 KW DC/80 KW AC roof mounted PV system.  (270) modules with (4) 20 KW inverters and a 112.5 KVA transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10321	15041-10000-09486	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.04443	-118.29612	replace fire alarm panel in an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10322	16041-10000-44933	245 N SOTO ST	90033	14	129A223   353	5183004028	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Approved	12/22/2016 12:00:00 AM	ADDRESS	34.04632	-118.20835	TITLE 24 FOR EXISTING BUILDING(MC DONALDS). INTERIOR REMODELING INCLUDING NEW LIGHTING AND ADDED COMBINED LOAD < 400A. TOTAL SQ FT. 2376	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10323	13041-10000-31486	1236 W LEIGHTON AVE ste#2	90037	8	117B197  1164	5037003003	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.01307	-118.29858	PV1, Install 2 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US.  8 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10324	18041-20000-14184	23275 W MULHOLLAND DR	91364	3	168B093   181	2074001042	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.15563	-118.63344	Plan check for energy only in existing restaurant new lighting. Total area indoor and outdoor: 19,173 sq ft.B#18041-20000-06227	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10325	19041-10000-31453	10931 N MARKLEIN AVE	91345	7	210B145   356	2664018006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.26925	-118.47063	(ePlan) PLAN CHECK FOR MAIN BREAKER DEATING. MAIN PANEL SIZE=225A WITH 150A DERATING. ORIGINAL APPROVED SET 19041-10000-23361	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10326	16041-10000-22715	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR ENERGY. TI  FOR LENSCRAFTERS INSIDE EXISTING MACYS. TOTAL AREA 1011 SQ FT.B#16016-40000-10551	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10327	18041-10001-15072	624 S GRAND AVE	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	Delta 2 revisions- added modules and few strobes(((((PC FOR NEW FA SYSTEM FOR ONE WILSHIRE INFRASTRUCTURE BUILT OUT FOR GENERATOR ROOM 1ST AND 2ND FLOOR. SCOPE INCLUDES SATELLITE FACP TO COMMUNICATE WITH MAIN FACP (UNDER DIFFERENT PERMIT) AND 19 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10328	18041-10000-36685	6757 W HOLLYWOOD BLVD #12	90028	13	148-5A185  92	5547011016	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	08/28/2020 12:00:00 AM	ADDRESS	34.10172	-118.33778	PLANCHECK FOR T24 ENERGY. Change of Use of 275 sf of Retail space to a Take Out Restaurant .BUILDING PERMIT # 18016-10000-08710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10329	14041-20000-25670	5321 N AMIGO AVE	91356	3	171B121   223	2161014024	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.16689	-118.53896	CENTRAL STRING INVERTER STANDARD PLAN. 6.8KW SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10330	18041-10000-36434	320 N VERMONT AVE	90004	13	138B197   196	5501001012	C2-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.07698	-118.29148	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10331	10041-10000-01479	316 N WESTERN AVE # C	90732	15	018B193   260	7452001027	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.02	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM			PC Approved	01/29/2010 12:00:00 AM	ADDRESS	33.74652	-118.30942	CHANGE OF USE FROM RETAIL TO YOGURT SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10332	11041-10000-24873	2500 W PICO BLVD	90006	1	129B197  1098	5075001001	[Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM			PC Approved	11/30/2011 12:00:00 AM	ADDRESS	34.04708	-118.29181	T.I. to an existing restaurant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10333	11041-10000-27379	801 N SEWARD ST	90038	4	141B185   240	5533024026	MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.08547	-118.33326	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR MANUFACTURING/WAREHOUSE BUILDINGNote: Permit under 11041-10000-27706	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10334	17041-20000-07138	4671 E HUNTINGTON DR SOUTH	90032	14	142-5A231  85	5213013020	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	03/06/2017 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.08562	-118.18389	Plan check for a fire alarm system. Fire alarm system is for a 2-story commercial building. System consists of (1) FACP, (1) annunciator, and (28) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10335	10041-20000-22890	10012 N WILBUR AVE	91324	12	204B121   553	2729007008	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2010 12:00:00 AM	01/05/2011 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	ADDRESS	34.25235	-118.54465	Roof mounted PV system with 11.1 KW.  Also permit for replacing 400 amp panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10336	10041-10000-12861	1660 W 3RD ST	90017	1	133-5A205 153	5153008014	C2-1	Central	Westlake		YES	2091.01	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.06052	-118.26744	TENANT IMPROVEMENTS AND CHANGE OF USE FROM RETAIL TO MEDICAL CLINIC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10337	19041-20000-53203	12681 W JEFFERSON BLVD	90066	11	102B161    25	4211009025	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			Reviewed by Supervisor	01/02/2020 12:00:00 AM	ADDRESS	33.97836	-118.41626	Plan check for PV roof mounted system, PV System size: 432.525KW with 395 PV Modules and 4 inverters(100KW) Suplly side connection.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10338	17041-10001-06141	5530 S MAIN ST	90037	9	108B205   774	5101015011	C2-1VL	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Apartment			03/02/2017 12:00:00 AM			PC Approved	03/02/2017 12:00:00 AM	ADDRESS	33.99167	-118.27376	PC ONLY FOR PV SYSTEM ON APARTMENT BUILDING. PERMIT ALREADY ISSUED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10339	16041-30000-23710	5340 W 102ND ST	90045	11	090B173   206	4129032007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	33.9435	-118.37386	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,035 sq. ft.Note: Building  has been pulled under 16016-10000-09473	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10340	18041-20002-12316	11408 W ALBATA ST	90049	11	135B145   685	4365017002	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.06362	-118.4613	11/8/2018changes to an approved set of plans.  changes noted delta 7.  changes to relocate equipment for future battery installation. ((((Plan check for PV roof mounted system. system size: 4.7kW with 17 modules and 17 microinverters. l))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10341	18041-20000-03880	8110 W 3RD ST	90048	5	138B173   973	5511029035	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.07202	-118.36628	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10342	18041-20001-10295	8854 S MAIN ST	90003	8	096A205   291	6041005033	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	33.95626	-118.27369	05-22-2019 Changes to an approved set of plan, changes include change lighting fixture type and transformers location. all changes has been clouded as delta 1 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10343	16041-10000-19439	6344 W ARIZONA CIR	90045	11	105B165   656	4110014008	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Commercial			06/03/2016 12:00:00 AM			PC Info Complete	11/08/2016 12:00:00 AM	ADDRESS	33.98055	-118.39751	FULL PC FOR POWER AND ENERGY. TI, CONVERSION OF EXISTING WAREHOUSE TO A KENNEL. SCOPE INCLUDE UPGRADING THE MAIN SERVICE TO A 1000A 120/240V 3 PHASE 4 WIRE SERVICE AND ADDING NEW PANELS. TOTAL AFFECTED AREA IS 21399 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10344	15041-20000-28322	16633 W VENTURA BLVD 11th floor	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.15823	-118.49571	Title 24 plan check only.  Total area = 442 sq. ft.  T.I. to existing kitchen space.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10345	12041-10000-05159	1510 N SAN PABLO ST 6TH FLOOR-Phase II	90033	14	135A225    62	5202004039	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.06266	-118.20215	"Energy Only. Tenant improvement. Sixth floor of USC office building. Phase 2, consistes of 2421 sqft. LIghting and E mergency Lighting Plan Check.  PERMIT FEES ARE UNDER ""INSPECTION""  <<<Complete Plan Check may be required subject to field inspection>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10346	15041-10000-35144	725 S FIGUEROA ST 21ST	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.04886	-118.26071	T-24, TI TO THE 21ST FLOOR OF AN (E) HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. OC FOR ENERGY ONLY. TOTAL SQ. FT. 14490.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10347	16041-20000-17967	10602 N PINYON AVE	91042	7	207B201   252	2566001074	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM			Corrections Issued	06/22/2016 12:00:00 AM	ADDRESS	34.26127	-118.28481	06-22-16 Applicant would like to pull permit online instead. Set to plan check only. {{PV1.  Instlal 6.9 DC kW roof-mounted PV system.  (23) modules with Enphase M250 microinverters.}}}}	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10348	19041-20000-41058	11881 W TERRA VISTA WAY #112	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10349	14041-10000-09008	12829 W GREENE AVE	90066	11	108B157  1643	4223015022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Issued	06/11/2014 12:00:00 AM	ADDRESS	33.9882	-118.42942	PV1, INSTALL 6.625 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTERS: SOLAREDGE SE6000A-US-ZB-U &(25) MODULES: SUNIVA OPT265-60-4-1B0REVISION TO ORIGINAL  APP#13041-10000-32005	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10350	12041-10001-12778	10230 N SEPULVEDA BLVD	91345	7	204B145   388	2660016028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM			PC Approved	09/05/2012 12:00:00 AM	ADDRESS	34.25618	-118.46707	"DELTA 2 CHANGES TO THE APPROVED PLANS. Remodel of an existing Car Dealer, upgrade to 1200Amp service, new subpanels, circuits, lighting.  Full plan check.  ""COMPLY WITH DEPARTMENT ORDER effective date 01/21/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10351	14041-20000-25601	2468 FLETCHER DR	90039	13	150A209    47	5437033009	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM			PC Approved	09/17/2014 12:00:00 AM	PIN	34.10696087	-118.25496702	REPLACE EXISTING 600AMP OVER HEAD SERVICE WITH THREE DWP METERS OVERHEAD  SERVICE TO SERVE ADDRESS 2468	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10352	10041-10000-15707	6842 N VAN NUYS BLVD 3RD	91405	6	183B149   647	2217009011	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	11/24/2010 12:00:00 AM	ADDRESS	34.19499	-118.44846	TI IN THE 3RD FLOOR OF HIGHRISE BUILDING. EPC IS FOR T24 AND EMERGENCY LIGHT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10353	17041-20000-10999	9137 W CORDELL DR	90069	4	144B169   166	5560016012	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2017 12:00:00 AM			PC Info Complete	05/22/2017 12:00:00 AM	ADDRESS	34.0939	-118.39113	PLANCHECK ONLY FOR POWER. MAJOR ALTERATION AND ADDITION TO EXISTING SINGLE FAMILY DWELLING. 1600 AMP SERVICE.  PERMIT UNDER BUILDING # 14010- 30000-00328	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10354	17041-10000-40887	1385 E PALMS BLVD	90291	11	111B149   161	4244028016	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.00337	-118.45151	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 7.88KWDC/ 7.6KW ACSCOPE INCLUDES 25 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10355	13041-20001-34554	6358 W NANCY ST	90045	11	102B165   226	4110011016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	33.97673	-118.39828	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 4.16KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10356	15041-20002-43046	964 S BERENDO ST PHASE 2	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	34.05378	-118.29358	5/4/2017changes to an approved set of plans.  changes noted delta K. changes include addition of receptacles, fixtures and recalculated  energy cals.  this is plan check only.  (((((Changes made to approved set - delta J revisons only.  Revision of lobby and theatrical lighting.  Reduced emergency inverter rating.  (4) fans, (1) BP, and additional audio equipment.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10357	14041-10000-01831	2727 E ALCAZAR ST	90033	14	133-5A229  65	5202023008	MR1-1	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.06071	-118.19393	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 10774 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10358	16041-10001-26379	12100 W WILSHIRE BLVD #430	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	08/16/16Changes to an approved set of plans. Changes include adding three new receptacles in the office spaces. Recepacles will be controlled.  Note: Permit is paid under PCIS#16041-10000-26379((((PC for title 24 only for 1526 sqft for commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10359	14041-10000-05446	1796 N NORTH SPRING ST	90031	1	138A219   137	5447026001	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07143	-118.2225	T24,REMOVING EXISTING LIGHT FIXTURES WITH NEW LIGHT FIXTURES. TOTAL AREA 3591 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10360	10041-10000-16567	1234 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.05003	-118.2261	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10361	12041-10000-10634	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	Plan check T24 Energy/Emergency lighting for 14th & 15th floor office remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10362	19041-10000-24428	9330 N DE SOTO AVE	91311	12	198B109    86	2748002070	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Issued	10/03/2019 12:00:00 AM	ADDRESS	34.23961	-118.58822	PC FOR T24 ENERGY ONLY FOR RESTROOM AND BREAKROOM ON 2ND FLOORSCOP E INCLUDES NEW LIGHTS RECEPTACLES, CIRUCITS, PANELS AND EQUIPMENT. TOTAL AFFECTED AREA 440 SQ.FT B#19016-10000-19313	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10363	10041-10000-18831	2050 W JOHN S GIBSON BLVD CRANE #4	90731	15	024B201     7	7440016912	[Q]M3-1	Harbor	Port of Los Angeles	Northwest San Pedro, Wilmington	YES	2951.01	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Closed	11/05/2012 12:00:00 AM	ADDRESS	33.75959	-118.28627	INSTALL A NEW CRANE AT BIRTH #102 IN TERMINAL WBCT.  (CRANE #4 of 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10364	17041-10000-37599	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.17126	-118.58861	PC PER APPLICANT REQUEST FOR TENANT IMPROVEMENT OF (E) PHARMACY. SCOPE INCLUDES NEW LOAD <400ANO NEW LIGHTS.B# 17016-10000-30921	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10365	19041-20001-36578	4544 N FORMAN AVE	91602	4	168B181   215	2420037014	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM			PC Approved	10/17/2019 12:00:00 AM	ADDRESS	34.1535	-118.35261	Plan check for PV roof mounted system, PV system size: 9.2KW DC with 23 PV Modules  connected to existing service. Plan check only, permit covered under master application 19041-90000-36578.Fees $63.49 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10366	15041-20000-00999	6125 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.09818	-118.32319	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT.  SUGARFISH RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10367	11041-20000-26510	1121 S BOYLE AVE 201	90023	14	123A221   272	5170008029	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			Not Ready to Issue	12/19/2011 12:00:00 AM	ADDRESS	34.03075	-118.22046	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE TI #201. EXISTING PERMIT UNDER #11041-90000-23140 and supplemental  permit  # 11041-20002-23140.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10368	11041-10000-23911	2020 S BUNDY DR	90025	11	123B149   367	4259020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.03347	-118.45477	tI WORK FOR AN EXISTING HARWARE STORE. ENERGY, OUT DOOR AND INDOOR, ADD GEN SET, POWER AND ENERGY. NOT A HIGH RISE. FIRE ALRM WILL BE DIFFERED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10369	18041-20000-08377	13443 W VAN NUYS BLVD 1-4	91331	7	207B157   700	2619025002	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM			PC Approved	03/07/2018 12:00:00 AM	ADDRESS	34.26341	-118.42607	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL. 950SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10370	13041-20000-16438	9301 N TAMPA AVE SPC# 78	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for energy and emergency lighting. Tailored method. P.S. from Aeropostale.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10371	15041-20000-33421	4860 N DON PIO DR	91364	3	168B105  1406	2171018094	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.15609	-118.60423	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10372	19041-20000-14601	18127 W CHATSWORTH ST #5A	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.26469	-118.52657	Change of use from bank to gym and tenant improvement work.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10373	19041-20000-00149	7254 N HINDS AVE	91605	2	186B169   910	2317019011	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Issued	01/03/2019 12:00:00 AM	ADDRESS	34.20283	-118.39092	PC FOR NEW SERVICE FOR A COMMERCIAL BUILDING. SCOPE INCLUDE 800A, 120/240V, 3PH, 4W. 5 PANELS. 1-400AMP , 4-200A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10374	15041-10000-27518	7195 W FORMOSA FUSION CT	90046	5	141B181  1711	5525003036	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08566	-118.3459	PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10375	12041-10000-12269	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to an existing retail space in the Century City Mall.  Change to lighting and receptacles.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10376	18041-10001-00358	5930 W PICO BLVD	90035	10	129B173   402	5068012046	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.05176	-118.36888	"Changes to an approved set of plans for an existing restaurant (McDonald). All changes are clouded under ""CB1"". Scope includes removing/relocating lighting fixtures on the lighting floor plans, and revising Title 24 calculations."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10377	19041-20000-01215	12175 N CREST AVE	91342	7	216B145   252	2611043025	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.29186	-118.46485	PV1.  Installation of 5.04 kW DC / 4.6 kW AC roof mounted grid tied PV system.  (14) modules with 4.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10378	15041-10000-02483	1718 S WESTERN AVE	90006	10	126B193   524	5074014043	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.04215	-118.30883	Plan check for T-24 only. for Bank of America. Total area: 400SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10379	19041-20000-53510	3613 N DIXIE CANYON AVE	91423	4	162B157   635	2386009024	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.14	-118.42676	PV1. INSTALL 15.84 KW DC ROOFMOUNTED PV SYSTEM WITH (48) MODULES AND MICROINVERTERS(ENPHASE IQ7X-96-2)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10380	14041-10000-35857	2530 S GREENFIELD AVE	90064	5	123B157    48	4256005025	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.03705	-118.4307	PV system. System size = 5.81kW. 27 modules, 27 microinverters (215 Watts). New 125 amp subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10381	10041-10000-13517	1155 N VERMONT AVE	90029	13	144B197   449	5540019017	C2-1D, RD1.5-1XL	Central	Hollywood	East Hollywood		1912.03, 1913.00	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.09247	-118.29194	REPLACING 2EA SERVICES WITH A 800A SERVICE TO SUPPLY EXISTING LOADS AND TO SUPPLY  A FUTURE LOAD (MRI TRAILER ) from a 200A 4p-5w receptacle	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10382	18041-20000-28175	17015 W RAYEN ST	91325	12	195B133   203	2690008018	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Issued	07/26/2018 12:00:00 AM	ADDRESS	34.23225	-118.50329	Plan check for a PV1 roof-mounted PV system. System size is 9.425 kWdc/8.67 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (29) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10383	19041-30001-19966	12400 W WILSHIRE BLVD #350	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.04157	-118.47031	06/06/2019 Plan check for Title 24 only. Project site is an existing tenant space in a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,269 sq. ft.Note: Building application has been generated under 19016-40000-15157*****Original Work Description*****SPEC SUITE REMODEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10384	14041-10000-05684	1434 N BENTON WAY	90026	13	142-5A205 332	5424016012	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.08429	-118.26789	PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCoNNECT WITH MAIN SERVICE PANEL.(17) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10385	17041-10000-46027	1815 N CAHUENGA BLVD	90028	13	150A187   283	5546001400	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM			Verifications in Progress	09/05/2018 12:00:00 AM	ADDRESS	34.10446	-118.33026	PC FOR POWER AND ENERGY FOR CORE AND SHELL RENOVATIONS TO PREPARE THE BUILDING FOR FUTURE TENANT SCOPE INCLUDES NEW ELECTRICAL SERVICE 800A 120/240V 3 PHASE 4 WIRE SERVICE,  NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS . TOTAL AFFECTED AREA  ABOUT 6000 SQ.FT (INDOOR AND OUTDOOR)  B#17016-10000-38014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10386	10041-10001-02737	12920 W RUNWAY ROAD	90094	11	102B157   315	4211021030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/06/2010 12:00:00 AM			PC Approved	10/06/2010 12:00:00 AM	ADDRESS	33.97447	-118.42112	PROPOSED 4-STORIES, 52-UNITS CONDOMINIUM W ONE LEVEL BASEMENT PARKINGREVISIONS TO PERMITTED SET OF PLANS- INSTEAD OF 3-METER STACKS OF 21 METERS, 21 METERS AND 10 METERS' THE INSTALLATION WILL HAVE A 31 METER STACK AND A 21 METER STACK. PLANS SHOW LARGER FEEDERS TO SUPPLY THE 31 METER STACK, VOLTAGE DROPS FOR THE FEEDERS TO THE ADDED 10 METERS, AND LOAD CALCULATION FOR THE SWBD SUPPLYING THE 31 METERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10387	15041-10000-02961	13292 W KAMLOOPS ST	91331	7	201B157   538	2622014020	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	34.24659	-118.42272	PV1 STANDARD PLAN FOR RESIDENTIAL. 17 MODULES AND 1 INVERTER. 6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10388	12041-10000-18269	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Info Complete	11/14/2012 12:00:00 AM	ADDRESS	34.0446	-118.21143	PLAN CHECK FOR POWER AND ENERGY. NO SINGLE LINE NOR TITLE 24 CALCS NOR PANEL SCHEDULES INCLUDED. MEDICAL CLINIC. LOW RISE COMMERCIAL. CIRCUIT COUNTS PER APPLICANT. SUBJECT TO CHANGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10389	06041-10002-25939	3410 S LA CIENEGA BLVD	90016	10	120B173   310	5047018901	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.02602	-118.3719	Modification to approved plans, see inverted Delta 3 as shown on the plans. Install north gate operator, hoist motor,  two VFDs and Two 200 HP fan motors as shown on page 5E5-01.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10390	17041-20001-41911	11925 W WILSHIRE BLVD 103	90025	11	129B145   934	4265014095	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.04655	-118.46473	03/06/2018 Changes to an approved set of plans. Changes include the addition of emergency egress illumination and exit signs.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO MEDICAL OFFICE/ PHYSICAL THERAPY FROM OFFICE.BUILDING PERMIT # 17016-30000-20145	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10391	16041-20000-33712	5441 N WILLIS AVE	91411	4	174B149  1148	2249026004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.16972	-118.45546	PV1.  Install 11.04 kW grid tied photovoltaic system.  (32) SunPower AC modules with 100A solar load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10392	10041-10000-18821	6109 N DE SOTO AVE	91367	3	177B105    43	2149005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	09/22/2010 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.18151	-118.5908	new fire alarm three story plus roof commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10393	18041-20000-46972	13407 N ANDALUSIA LANE LOT 6	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.31497	-118.4226	Plan check for PV roof mounted system,system size: 1.68KW with 7 PV Modules and7 microinverters. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10394	18041-20000-20562	304 S BROADWAY I-218	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.05076	-118.248	Plan check for Titel 24 Energy in existing retail space T.I. lighting. Total area; 2780 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10395	12041-10000-08861	16851 W HART ST	91406	6	183B133   530	2225020024	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	06/15/2012 12:00:00 AM	ADDRESS	34.19764	-118.50073	roof -mounted  photovoltaic sytem on the roof of a sfd with Enphase microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10396	18041-30000-23137	525 N WILTON PL	90004	4	141B189   779	5522015024	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.08101	-118.31378	Plan check for a fire alarm system located in a new 4-story 88-unit apartment building. Scope include (1) fire alarm system, (6) power supplies and (281) fire alarm devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10397	16041-20003-20723	7900 N BALBOA BLVD Bldg Delta	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Closed	12/03/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	"02/15/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. New distribution equipment has been installed, along with new loads.(((Plan check for power and energy for Van Nuys Airport Building ""D"" (Delta) aircraft hangar. Service size: 800A. Total area: 32,845 sq ftBuilding Applicant #: 16010-30000-01587)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10398	12041-10000-22108	15643 W WYANDOTTE ST 1-19	91406	6	186B141   720	2206029016	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00	Electrical	Electrical	Public Safety Only			09/17/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.20311	-118.47409	NEW FIRE WARNING  SYSTEM  FOR  19 UNITS, 3-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10399	12041-10000-22876	2970 W OLYMPIC BLVD Suite #201-- 206	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	T.I. for office space suite #201 and 202, medical offices suite #203, 204, 205, 206.  Install new panel #203, new branch circuits, and lighting for a suites.   Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10400	19041-10000-49634	117 S GARDNER ST	90036	4	138B177   682	5512007004	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.07294	-118.35333	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 7.56KWdc (7.6KWac) USING 24 QP315 MODULES, 24 SE P400 POWER OTIMIZERS & SE-7600H-US CENTRAL INVERTER. ESS TESLA POWERWALL.CONNECTED TO A 200 AMP EXISTING SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10401	17041-10000-38848	1192 E 51ST ST	90011	9	111A209   409	5104001900	PF-1	South Los Angeles	Southeast Los Angeles			2287.10	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	PIN	33.99633967	-118.25435196	REPLACE INDOOR AND OUTDOOR LUMINAIRES WITH LED TYPESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10402	16041-20000-02229	1431 S ARMACOST AVE 1-13	90025	11	126B145   300	4263031012	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			01/21/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.04303	-118.46148	Plan check for new 13 Appartment units. Total indoor area: 15,501 sq ft and out door area: 2,160 sq ft. Service size: 1,200A. Fire alarm variance has been filed.Note: Applicant has pre-cut check. Out door area shall be added on final 2,160 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10403	18041-10000-40675	16255 W VENTURA BLVD 925, 940	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.15711	-118.48768	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENTFOR TWO SUITES. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SPACES. TOTAL AFFECTED AREA IS 3243 SQ. FT. B#18016-10000-22903	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10404	16041-10001-21592	1101 W 23RD ST	90007	1	124-5A201 212	5124001012	[Q]C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM			PC Approved	07/15/2016 12:00:00 AM	ADDRESS	34.03511	-118.28354	PC FOR ENERGY. T.I CHANGE OF USE FROM BEAUTY SALON TO A PREPACKED FOOD RESTURANT. TOTAL AREA 1027 SQ FT. B # 16016-10000-12370NOTE: Permit fees were paid under express permit # 16041-10001-21592	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10405	17041-30000-19902	1200 W WILSHIRE BLVD Suite 100B	90017	1	130-5A207  69	5143019022	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.05294	-118.26512	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 7,618 sq. ft.Note: Building application has been generated under 17016-30000-10911	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10406	11041-10000-25986	17401 W VENTURA BLVD B20	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.16136	-118.51189	"TI  WORK  FOR  (E)  RESTAURANT  (2ND FLOOR)  ""OTO-OTO  JAPANESE RESTAURANT""  ADD PATIO DINING, REVISE SEATING PLANPLAN CHK IS FOR LIGHING/EMEGENCY COMPLIACE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10407	13041-20003-03721	1901 S BUNDY DR BLDG 1	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	34.03497	-118.45709	Changes from previously approved plans.  Permit issued under 20001 PCIS #.  Addition of one outdoor building sign resulting in changes to title 24 compliance sheets.*****Previous Description*****Changes from previously approved plans.  Change in outdoor lighting control panel only.  *****Previous Description*****1901 S BUNDY DR BUILDING #1.  OUTDOOR LIGHTING AND INDOOR LIGHTING FOR HALLWAY AND RESTROOMS IN EXISTING SINGLE STORY OFFICE BUILDING.  ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10408	12041-10000-10101	23671 W BLYTHE ST	91304	3	189B093   329	2020007041	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	06/06/2012 12:00:00 AM	ADDRESS	34.2143	-118.64316	New 7.74kw rooftop photovoltaic system for an existing single family residence.  Partial Permit is under #12041-10000-04351	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10409	18041-20000-29144	23807 W HARTLAND ST	91307	12	183B089   650	2034031042	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.19441	-118.64489	PV1.  Install 11.655 kW roof mounted grid tied PV system.  (37) modules with 5.2 and 7.6 kW rated string inverters.  Main breaker derated to 150A to accommodate PV system size.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10410	17041-10000-08626	7909 N TOPANGA CANYON BLVD	91304	3	189B101   465	2012013027	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.21398	-118.6062	Plan check for Title 24 only, replace existing lighting fixtures with LED fixtures. Total area: 15,675 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10411	15041-10000-42982	1925 S CENTURY PARK EAST 15th floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.06066	-118.41426	PC for energy only to a commercial building (Office, 15th floor). Adding new ligting and power. Total sq ft = 344.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10412	16041-20000-43900	4719 N CALHOUN AVE	91423	4	168B153   478	2248028013	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.15663	-118.44231	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.(N) 3kW ungrounded system. (8) 265W pv modules. There is an existing 3.8kW ungrounded system installed on the SFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10413	11041-20001-03631	300 S GRAND AVE 4th Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	PIN	34.05243427	-118.25124731	Modification to an approved set of plans.  Changes are to rooms 434 and 430, 433 and 436.  In rooms 436 and 436, no work will be done.  Room 433 is a new room were work will be done.  Room 436 has some modification to the quanity of lights and the type of occupany sensor used.  Plan chek is for energy only.  <<<<<<<<<T.I. to a high rise building JP Morgan Chase.  Install general/emergency lighting.  Plan check for energy only.>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10414	16041-20004-20464	14748 W KESWICK ST	91405	6	186B149    26	2210028008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM			PC Approved	08/14/2017 12:00:00 AM	ADDRESS	34.21015	-118.45472	"8.14.2017 - Plan check for changes to approved set of plans. Changes clouded delta 3. Changing equipment to Siemens, update model of  breakers for series rating to 42kAIC. Reduce conduit size for AC2 feeder to 2"". Change subpanels (A, B, C, D, AC1, AC2) to MLO.=====08/01/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the distribution equipment AIC rating and some of the feeders. 7/14/17changes to an approved set of plans.  changes include updating plan to reflect field conditions.  this ia plan check only.  (((New service and build out for (E) plant cultivation building in response to code enforcement action.  Plan check for power and energy.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10415	17041-10000-10613	16640 W VENTURA BLVD	91436	5	168B137   356	2284007015	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.15783	-118.49565	TITLE 24 ONLY FOR NON-STRUCTURAL EXISTING (6438 SF)  BANK OF AMERICA INTERIOR TI ONLY ( NO CHANGE USE). TOTAL SQ FT. (6147)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10416	13041-10000-19759	10323 N FARMINGTON AVE	91040	7	204B189   458	2560001028	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.25682	-118.32186	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 6.48 KW. USING MICROINVERTERS: ENPHASE # M215-60-2LL-S22 AND MODULES: REC # REC 240 PE. 30 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10417	19041-10000-33120	1820 N LAS PALMAS AVE	90028	13	150A185   262	5547003900	OS-1XL	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	03/02/2021 12:00:00 AM	ADDRESS	34.10465	-118.33611	NEW FIRE ALARM SYSTEM IN THE BUILDING WITH 54 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10418	16041-20000-37610	201 N FIGUEROA ST 16th floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	PLANCHECK FOR T24 ENERGY ONLY. INTERIOR T.I. FOR 16TH FLOOR. NEWLY CONNECTED LOAD LESS THAN 400AMPS PER APPLICANT. LAPD OFFICES. HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10419	15041-20000-40283	6625 N NESTLE AVE	91335	3	180B125   363	2125018016	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.19108	-118.53091	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (29) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10420	19041-10000-52280	5405 N HERMITAGE AVE	91607	2	171B165    62	2347008021	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	34.169	-118.40053	PLAN CHECK FOR A NEW FIRE ALARM IN APPARTMENT COMPLEX. SCOPE OF WORK INCLUDES 1 FACP, 1 POWER SUPPLY, 1 ANNUNCIATOR AND 84 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10421	12041-10001-16266	7122 N AMIGO AVE	91335	3	183B121   252	2126006017	(T)(Q)RAS3-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			06/19/2013 12:00:00 AM			PC Info Complete	06/19/2013 12:00:00 AM	ADDRESS	34.20004	-118.53846	14 unit apartment bldg, 3 story , type V.  variance  to be filed in order to separate fire alarm.((((((((((((((((((((((((((((((((((((  6-19-13   changes made to previosly approved set. , coductors changed to ser, % voltage drop.)))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10422	13041-10000-08463	416 S SPRING ST Basement	90013	14	129A211   276	5149038***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.04837	-118.24848	Plan check power and energy. First time tenant for a new bar in existing highrise building basement.  Assemble occupancy. El Dorado Bar	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10423	10041-10000-15311	16571 W VENTURA BLVD B	91436	5	168B137   296	2259018022	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	10/22/2010 12:00:00 AM	ADDRESS	34.15798	-118.49405	TENANT IMPROVEMENT FOR AN EXISTING RETAIL SPACE, PET FOOD AND SUPPLIES. PLAN CHECK FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10424	19041-10000-45837	4925 S COMPTON AVE	90011	9	111A211   327	5107030007	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.20	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	33.99769	-118.24796	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10425	14041-10000-14401	564 S MATEO ST	90013	14	126A217    69	5164006015	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.03964	-118.23268	TI IN STORAGE AREAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10426	18041-10000-21174	10250 W SANTA MONICA BLVD Kiost 9270	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Initial Tenant Improvement to existing Food & Beverage Kios ""Leaff"" on ste# 9270PLAN CHECK IS FOR TITLE 24 AND POWER - NEW PANEL AND CIRCUITS"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10427	17041-10000-43362	12103 W VENTURA PL	91604	2	165B165  1211	2368002014	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Info Complete	12/01/2017 12:00:00 AM	ADDRESS	34.14501	-118.39527	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM MEDICAL OFFICE TO SMALL GYM. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2814 SQ. FT. B#16014-20000-05315	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10428	18041-10000-36010	444 S FLOWER ST Ground Flr	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	TI IN AN EXISTING COMMERCIAL SPACE IN THE LOBBY AREA ON THE GROUND LEVEL. T-24 ENERGY ONLY.BLDG PERMIT: 18016-10000-19379	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10429	16041-20000-12351	309 E 8TH ST STE 202	90014	14	126A211    30	5145003009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.04121	-118.25128	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,336 sq. ft.Note: Building permit has been pulled under 16016-10000-02985	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10430	18041-20001-11681	4257 N NOELINE AVE	91436	5	165B137   273	2284019009	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.14852	-118.48753	05/01/2018 Changes to an approved set of plans. PV system size has been reduced to 3.85 kWac-CEC/4.32 kWdc consisting of (12) AC PV modules.*****Previous Work Description*****pv1install roof ounted pv system sized 11.8kw AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10431	14041-20000-06769	1276 N BENEDICT CANYON DR	90210	5	144B157   205	4356028003	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.09186	-118.42814	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 28 MODULES. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10432	12041-20000-16392	2237 S COLBY AVE	90064	11	123B153   313	4260015019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.03491	-118.44424	T-24 and emergency lighting plan check for CHANGE OF USE FROM PORTION OF OFFIC & MANUFACTURING  (7400 S.F.)  TO ANIMAL CLINIC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10433	13041-10000-36273	1019 S SAN JULIAN ST	90015	14	124-5A211  51	5145019014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.03654	-118.25283	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 512 SQ FT. REPLACING TOTAL OF 3 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10434	13041-10000-16436	750 S LAMAR ST rd storage	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE  (8.) roadability storage  (1620 SF open structure) BUILDING.Note: all counted devices fee are under 13041-10000-16425 (Roadability Canopy)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10435	15041-20003-19438	225 N VERMONT AVE	90004	13	138B197   568	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			07/19/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.07529	-118.29188	[[7/19/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 6 CHANGES ONLY.  UPGRADING  FEEDERS AND BREAKERS FOR  ELEVATORS AND INVERTERS . ALSO CHANGING BREAKERS FOR SUMPPUMPS]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10436	10041-10000-02118	5601 N DE SOTO AVE #1961	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check for replacing an existing X-ray equipment.  New X-ray load was reduced.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10437	19041-30000-31582	350 S BIXEL ST 200	90017	1	132A209    99	5152014038	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.05673	-118.26007	Tenant improvement for an office title-24 only. Total area 2,202 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10438	10041-10000-25661	10750 W MISSOURI AVE 1-8	90025	5	129B153   509	4321010025	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			12/28/2010 12:00:00 AM			PC Info Complete	12/28/2010 12:00:00 AM	ADDRESS	34.04982	-118.43246	Ti in the corridoor & storage area of  an appartment building. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10439	17041-10000-18900	6848 N FIRMAMENT AVE	91406	6	183B141   677	2234002009	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.1955	-118.47276	$0 permit fee due to senate bill 1222 from 2012PC FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE 15.2KWAC INCLUDES 57 MODULES WITH OPTIMIZERS.PLAN CHECKER TO VERIFY CLEARANCE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10440	11041-20000-22073	5031 N FAIR AVE	91601	2	171B173  1095	2353012016	R4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			10/14/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.1617	-118.37478	new Fire Alarm	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10441	18041-20000-10479	5819 N MAMMOTH AVE	91401	2	174B153   212	2246010007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.17643	-118.43248	Plan check for the addition of a Tesla PowerWall onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10442	11041-10001-21412	250 S HARBOR BLVD Ticket-2OF3	90731	15	018B201   623	7440030***	M2-1, [Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			PC Info Complete	06/14/2012 12:00:00 AM	ADDRESS	33.74182	-118.27938	Ticket Booth Building 2 of 3.  <<<<<<SITE DEVELOPMENT FOR USS IOWA BATTLE SHIP PROJECT AT BERTH 87.  SCOPE OF WORK INCLUDES PROVIDING POWER TO THE SHIP AND THE ACCESSORY BUILDINGS AT 34.5KV TO 6.6KV TO 480V TO 208/120V.   (1 OF 3 ).    (RESTROOM BUILDING WAS SUBMITED UNDER 11041-10001-21412) AND (THE TICKET BOOTH BUILDING WAS SUBMITED UNDER 11041-10002-21412).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10443	18041-20000-12297	1852 N MARCHEETA PL	90069	4	150B169  1092	5561008033	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.10612	-118.38882	Plan check for PV roof mounted system. System size: 27kWac with 75 AC Modules connected to load center with existing 400A service.Permit fees $63.64 due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10444	19041-10000-23475	9155 N WINNETKA AVE Bldg 2	91311	12	198B113   212	2748039030	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			Corrections Issued	02/04/2020 12:00:00 AM	PIN	34.2368297	-118.57294016	Full plan check for a new Industrial Warehouse Building core and shell (Building 2).Scope includes new 2000A service. Total affected area 4914 sq.ft 2 of 3B#19010-10000-01404	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10445	19041-10001-30030	137 W 60TH ST	90003	9	105B201   473	6005015019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	33.98524	-118.27528	Revision to an approved PV1 set. change include reducing the # of modules and the rating of inverter and circuit breaker to main panel. permit fee under original permit  original>PV1 NEW ROOFOTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10.07 KWdc/10KWac. SCOPE OF WORK IS 33 MODULES (HANWGA Q-PEAK 305) WITH OPTIMZERS (SE-P320) AND A CENTRAL INVERTER (SE10000H-US). PANEL UPGRADE WILL BE PULLED UNDER A SEPERATE PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10446	18041-10002-04978	9851 S ALAMEDA ST SHOPS 1	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM			PC Info Complete	05/10/2019 12:00:00 AM	ADDRESS	33.94801	-118.22929	Revision to approved core & shell. All changes are noted as Delta-4. Revision includes:(1) Consolidation of space A and B to be just one space. (2) Remove 200A panel for space A&B, and create one panel for 400A(3) Revise SLD accordingly(4) Adding new 400A section in swithcboard <<PC FOR POWER ONLY, NEW SHELL 1-STORY WITH 6 RETAIL SPACE. SCOPE OF WORK INCLUDES NEW 1200 AMP, 120/208 V SWITCHBOARD,  HOUSE PANEL AND PANELBOARDS FOR FUTURE RETAIL SPACE. SITE LIGHTING IS UNDER A SEPARATE PLAN WITH APPLICATION NUMBER # E18LA00608. SITE LIGHTING AND EVCS ARE FED FROM SHOPS-2 POWER(JORDAN DOWNS PHASE 1C, SHOPS 1)>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10447	16041-10000-20591	1000 W WILSHIRE BLVD	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.05085	-118.26078	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING CAFE AND MAIN LOBBY SPACE. SCOPE INCLUDES ADDING A NEW LIGHTING AND RECEPTACLES.  TOTAL AFFECTED AREA IS 2350 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10448	13041-10001-03270	888 S OLIVE ST	90014	9	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Closed	12/31/2015 12:00:00 AM	ADDRESS	34.04383	-118.25785	CHANGES TO APPROVED SET OF PLAN. CHANGES ARE CLOUDED. SCOPE CHANGE NARRATIVE IS ATTACHED. UPGRADE OF SERVICE TO 1000AMPS, 250HP FIRE PUMP, 30KVA TRANSFORMER, 2 (50 HP MANLIFT), 15 HP PLACING BOOM AND CHANGES TO SERVICE LOAD CALCULATIONS. ORIGINAL DESCRIPTION: NEW 800A TEMP SERVICE.  for the construction of NEW 32 STORY APARTMENT, MIX USE.POWER FOR CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10449	16041-20000-40305	1500 S HI POINT ST	90035	10	129B173   774	5068018004	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			11/15/2016 12:00:00 AM			Reviewed by Supervisor	12/30/2016 12:00:00 AM	ADDRESS	34.04983	-118.36906	New 4 story apartment building with 45 dwelling units over 1 level of subterranean parking garage.  1600A 208Y/120V 3ph/4w service.  Plan check for power and energy.  Building permit submitted under 16010-10000-02288	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10450	11041-20000-16331	11600 W WILSHIRE BLVD 1st fl. co	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	12/11/2012 12:00:00 AM	ADDRESS	34.05034	-118.45947	1st floor corridor remodelEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10451	15041-10000-01999	6600 N TOPANGA CANYON BLVD 2042	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR  ENERGY. TI FROM RETAIL TO RETAIL. TOTAL AREA 3126 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10452	14041-10000-26988	5049 W EXPOSITION BLVD	90016	10	120B177   797	5046012027	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.02493	-118.35381	Plan check for power and energy. Core and shell. Existing building. 1 story. Building permit number: 14016 10000 19795	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10453	18041-20001-01530	19466 W ROSITA ST	91356	3	168B117   310	2178013038	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.15672	-118.55819	expeditepv1install roof mounted pv system sized 14.5kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10454	13041-10000-27350	21717 W NORDHOFF ST	91311	12	198B105   231	2746012042	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.23562	-118.60243	New 91.56kw PV system to be connected directly to the utility (not to feed the building).$0 PERMIT FEE IS DUE TO THE 2012 SENATE BILL NO. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10455	13041-10001-28009	5857 S CENTRAL AVE # 170	90001	9	108B209  1588	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			Corrections Issued	02/21/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	Revisions to approved set Minor panel load schedule adjustments.  Addition of shunt trip for convection oven load.  (((pc for power and energy. FIRST TIME TENANT TO A CORE & SHELL COMMERCIAL BUILDING. 'WINGSTOP' RESTAURANT. FULL PLAN CHECK PER SUPERVISOR. TOTAL AREA TO BE 1740 SF. SIGN LIGHTING TO BE IN SCOPE OF WORK IN ADDITION TO GENERAL/DISPLAY LIGHTING FOR THE SPACE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10456	17041-10000-46311	9742 N TOPANGA CANYON BLVD	91311	12	201B101   316	2746018023	QMR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.24724	-118.60642	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10457	13041-20000-32869	12641 W PRESNELL ST	90066	11	105B157   533	4221027028	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	33.98392	-118.42249	PV1 CENTRAL INVERTER SYSTEM WITH FOUR STRINGS. TOTAL SYSTEM SIZE 9.36KW. 36 PANELS AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10458	15041-20000-35922	10450 N DE SOTO AVE	91311	12	207B109   628	2706015033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.26047	-118.58835	PERMIT FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.Plan check for a PV1 roof-mounted PV system. System size is 13 kWac and consists of (2) inverters, (48) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10459	15041-10000-12959	5800 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Closed	02/03/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	TEMP POWER FOR CONSTRUCTION SITE 2000 AMP.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10460	15041-10000-43257	3755 W 60TH ST	90043	8	105B185   388	4004018013	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	33.98547	-118.33964	PV1 7.3KW roof-mounted system with (34) Sun Edison SE-F265CYC  modules and (34) Enphase Microinverter, and (1) loadcenter panel interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10461	15041-20001-02606	12492 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	02/01/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10462	17041-20001-30078	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005902	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.01318	-118.34004	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 86 kWac and consists of (2) inverters, (342) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10463	19041-10000-32551	10250 W SANTA MONICA BLVD 1280	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC for T24 only, scope of work is change of use from a restaurant to a medical clinic office (no medical equipment, no exam rooms, only consulatation). Scope of work includes new lighting, controls, and circuits. Total affected area is 3146 sqft. Power plan check is subject to field inspection. B#19016-10000-25990	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10464	12041-10000-08043	537 S BROADWAY Basement	90013	14	129A211   120	5149033003	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM			PC Approved	04/09/2012 12:00:00 AM	ADDRESS	34.04731	-118.25166	Basement- -Storage -- for an existing high-rise building.  New lighting, outlets, air conditioning, new restroom and cieling.  Load is 118.9 Amps, per applicant.  PLAN CHECK ONLY for Energy.  There may be ongoing projects in different floors, if total load from these projects is greater than 400A, a Full Plan Check may be required.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10465	18041-20000-09475	19257 W ROSCOE BLVD	91324	12	192B117   687	2784019007	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.22065	-118.55282	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,003 sq. ft.Note: Building application has been generated under 17016-20000-34033	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10466	14041-20000-14484	10050 W CHARDONNAY CT	91352	2	189B181   715	2403010016	[Q]RD6-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Expired	07/14/2016 12:00:00 AM	ADDRESS	34.2164	-118.35041	PV1.  Install 6.00 kW roof-mounted utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10467	17041-10000-02667	641 W 40TH PL	90037	9	115-5A201  92	5019025055	C2-1, R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.01065	-118.28546	PC for energy only, indoor and outdoor. This is an affordable apartment building, total of three stories. New lighting, and power. Also replacing like for like type light fixtures. Total area: 83,000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10468	19041-10000-30718	9522 S AVIATION BLVD TPSS-3	90045	11	093B173   321	4128010911	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	33.94995	-118.37733	PC FOR POWER AND ENERGY FOR CONSTRUCTION OF A NEW TRACTION POWERED SUBSTATION (TPSS #3) FOR LAX AUTOMATED PEOPLE MOVER PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10469	19041-20000-06857	8500 S PERSHING DR PV-1	90293	11	096B153  1023	4118004015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	06/09/2021 12:00:00 AM	ADDRESS	33.9561	-118.442	PV2.  Install 40.15 kW DC / 36.69 kW AC roof mounted grid tied PV system.  (110) modules with 33.3 kW rated string inverter.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10470	11041-20000-20573	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM			PC Approved	09/27/2011 12:00:00 AM	ADDRESS	33.78734	-118.29768	Open parking lot.  Replacing the light post and light fixtures in the open lot.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10471	18041-20000-25466	9007 N WOODMAN AVE #D	91331	6	195B153   291	2639033006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.23306	-118.43913	Change of use from retail to restaurant.  Plan check for energy only.  2171 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10472	19041-20000-18052	20116 W VINTAGE ST	91311	12	204B113   702	2741012028	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.25173	-118.57176	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 8.06KW DC/6.24KW AC. SCOPE OF WORK INCLUDES (26) MISSION SOLAR 310W PV MODULES AND (26) ENPHASE IQ7 MICRO INVERTERS AND A IQ COMBINER 3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10473	13041-10000-07105	10201 W PICO BLVD Bldg 101-5th fl	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	renovation of offices on 5th fl of offfice buildingPlan chk is for title 24 and 1 ea emergency cktPERMIT TO BE OBTAINED AT ELECTRICAL COUNTER 4TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10474	12041-20000-07177	2121 S AVENUE OF THE STARS LL10 LL30-LL40	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	TI for Fitness Center, Avenue of the Stars. Plan check for energy and emergency lighting. High-rise building.  3,360 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10475	17041-20000-31105	832 N HANLEY AVE	90049	11	138B137   387	4494009012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Issued	09/13/2017 12:00:00 AM	ADDRESS	34.07315	-118.48689	pv1install roof mounted pv system sized 15.8kw interconnected with msp.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10476	14041-10000-25766	7872 N VAN NUYS BLVD	91402	6	189B149   646	2212028012	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.21445	-118.44622	New fire alarm system including (20) devices and a panel in a commercial retail store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10477	16041-20001-03687	8658 W APPERSON ST	91040	7	204B189   644	2561003015	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.25596	-118.32226	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 11.4kW with 44 modules  SUNPOWER SPR327NE-WHT-D and 1 inverter SOLAR EDGE SE11400A-US.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10478	18041-10000-42419	7441 N TAMPA AVE	91335	3	186B117   463	2116016002	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.2058	-118.55372	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10479	19041-20001-28143	3860 S 3RD AVE pv1	90008	10	117B189  1008	5034017047	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM			PC Approved	08/06/2019 12:00:00 AM	ADDRESS	34.01608	-118.32022	expeditepv1install roof mounted pv system sized 5KW AC interconnected with msp.this is an addition to an existing system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10480	17041-10000-37175	7540 WORLD WAY Delta-Hangar	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	33.94052	-118.42863	PC power for service routing from 600A 4160kV meter switch  to 3750kVA transformer. Transformer to supply future 4000A switchboard (under future permit) for future hangar. B# 17030-10000-04011. LAX Project	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10481	13041-10000-14704	505 S FLOWER ST B-13	90071	14	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.0515	-118.25654	PC FOR ENERGY ONLY. TI FOR STARBUCKS. HIRISE. less than 400a and not touching the existing emergency lighting: per applicant . interior remodel of existing starbucks coffee tenant improvement. replacing some existing casework; replacing furniture; minor equipment changes (removals/additions); new interior)NONSTRUCT INT T.I. (406SF) OF EXISTING COFFEE RESTAURANT WITHIN EXISTING FOOD COURT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10482	16041-10000-27012	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check for Power and Energy on TBIT North Concourse of Tom Bradley Int'l Terminal.  Replace circuit breakers for motor loads, adding branch ckts, total affected area for T-24 is 20,000 S.F. (outdoor) (B# 16016-10000-17585)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10483	09041-20009-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			Corrections Issued	01/22/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	Modification to previously approved set of drawings for DELTA 215 Only on Sheet E400.<<<<T. I. - new medical office bldg.(NEW HIGH RISE BUILDING, MEDICAL OFFICE, SHELL UNDER PCIS 08041-20000-22411)>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10484	16041-10000-13168	7431 N FAUST AVE	91307	12	186B097   584	2022011018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.20547	-118.62078	PV1 roof mounted solar system to a single family home. Inverter rating: 11.4 kw , (49) Solar Modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10485	16041-10001-28680	13439 W BURBANK BLVD	91401	2	174B157   540	2343015018	(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			08/12/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.17234	-118.42584	Expedite per applicant request(((((Plan check PV2 roof mounted system. System size: 21kW with 3 inverters(SMA SB7000TL-US-208)  and 60 modules(CS6X-320)  connected to House panel of the appartement building.)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10486	17041-10000-22472	3527 N CAMINO DE LA CUMBRE	91423	4	159B149   181	2274021006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.13484	-118.44697	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 14.061 kWac.  AC module system.Permit fees are based on the Sent. Bill for PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10487	16041-10000-41680	4574 W ADAMS BLVD	90016	10	123B181  1006	5050003026	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM			PC Approved	11/28/2016 12:00:00 AM	ADDRESS	34.03239	-118.34027	PC FOR TITLE 24. ENERGY ONLY FOR COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING INDOOR AND OUTDOOR. TOTAL AFFECTED AREA 3080 SQ.FT. 975 OUTDOORS2105 INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10488	17041-10001-12599	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.02557	-118.3665	PC FOR CHANGES TO APPROVED SET OF PLANS. ADDED KITCHENETTES. PROVIDED UPDATED CIRCUITRY, LIGHTING CHANGES AND ALSO UPGRADED SERVICE TO 5000A. ALL CHANGES NOTED ON PLANS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10489	17041-10000-21386	7866 W FAREHOLM DR	90046	4	147B177    94	5551004011	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	01/20/2018 12:00:00 AM	ADDRESS	34.10298	-118.36114	PC FOR PV SYSTEM. TOTAL SIZE 11.5KW AC. USINCE AC TYPE SOLAR PANELS. TOTAL OF 32 AC MODULES. ALL ROOF MOUNTED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10490	19041-20000-53690	732 S WARNER AVE	90024	5	135B153   149	4360027008	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	06/16/2021 12:00:00 AM	ADDRESS	34.06783	-118.43304	PV1. INSTALL 9.30 KW DC ROOFMOUNTED PV SYSTEM WITH (30) MODULES, OPTIMIZERS AND (1) INVERTER (SE7600H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10491	17041-20001-28025	12355 W EMELITA ST	91607	2	174B165    99	2340008030	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM			PC Approved	08/21/2017 12:00:00 AM	ADDRESS	34.17641	-118.40253	Expedited per applicant request.Plan check for the addition PV system onto an existing PV1 roof-mounted PV system. System addition size is 5.2 kWac and consists of (1) inverter, (21) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10492	16041-10000-34606	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.07457	-118.37864	TENANT IMPROVEMENT TO PARTIAL AREAS WITHIN 8TH AND 9TH FLOORS OF (E) MEDICAL HIGHRISE BUILDING.  DEMO OF OFFICE SPACES FOR EXPANSION OF LAB AREAS.  NEW PANELS WITH NEW LIGHTING AND RECEPTACLES + NEW ROOFTOP EQUIPMENT.  TOTAL AREA = 15,666 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10493	19041-10000-10658	11544 W SHELDON ST	91352	6	201B169    93	2538021012	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.2467	-118.3833	Remove HID fixtures and replace with new LED fixtures (Outdoor Only), - T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10494	16041-10005-45090	1301 W 7TH ST	90017	1	130-5A205 108	5143013022	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			11/27/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.05249	-118.26766	"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 31. CHANGES INCLUDE REVISING PANEL SCHEDULE ""SBHP"",  ADDING TWO EXHAUST FANS, AND REVISING LOAD CALCULATIONS."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10495	19041-20000-51863	19706 W VICTORY BLVD	91367	3	180B117   887	2134032006	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.18638	-118.56264	PV1. INSTALL 12KWDC ROOF MOUNTED PV SYSTEM WITH (32) MODULES, OPTIMIZERS AND (1) INVERTER (SE11400H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10496	13041-10000-02675	3619 N REGAL PL 1-12	90068	4	159B177   184	2425004015	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Apartment			02/01/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.13397	-118.36304	New fire alarm system for apartment. 1 Fire alarm panel and 12 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10497	19041-10001-33988	13517 W BAYLISS ROAD	90049	11	138B133   344	4492014019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.07375	-118.50495	PLAN CHECK ONLY. DELTA 1 CHANGES TO APPROVED SET TO REMOVE THE 100A SUBPANEL AND CONNECT THE PV SYSTEM TO THE MAIN SERVICE PANEL. (((((PV1. INSTALL 7.75 KW DC SOLAR SYSTEM WITH (25) ROOF MOUNTED MODULES AND MICROINVERTERS (ENPHASE IQ-7-60-2-US).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10498	17041-20000-02806	920 S BERENDO ST	90006	10	132B197   952	5094025017	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			01/27/2017 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	07/14/2021 12:00:00 AM	ADDRESS	34.05515	-118.29398	new 1200 amp service to new 4-story, 27-unit apartment building. 3 levels of residential over ground level & subterranean level parking.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10499	16041-10000-19529	3334 S CABRILLO BLVD	90066	11	114B149   133	4247018017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM			PC Approved	06/11/2016 12:00:00 AM	ADDRESS	34.01139	-118.44623	New 3kw solar system being added to an existing 2kw system. Total system size is 5KW. (14) modules (1) solar edge Inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10500	18041-10000-27227	1609 S BARRINGTON AVE	90025	11	126B149   508	4262012025	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.0423	-118.45502	*permit fee zero dollar per AB-1414/SB-1222**PC FOR NEW ROOF MOUNTED PV ON CHURCH.TOTAL SYSTEM SIZE 47.6KWDC/37.5KWACSCOPE INCLUDES 138 MODULES AND 3 CENTRAL INVERTERS (12.5KW EACH).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10501	14041-20000-32298	5251 N VINELAND AVE UNIT: E	91601	2	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.16639	-118.37064	RESTAURANT. NEW LIGHTING. PC FOR T24 ENERGY ONLY. PC ONLY. PERMIT ISSUED UNDER SEPARATE APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10502	10041-10000-00573	801 N FAIRFAX AVE #108 & 109	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1920.00, 1944.00	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	03/08/2010 12:00:00 AM		Permit Finaled	04/20/2010 12:00:00 AM	ADDRESS	34.08567	-118.36172	TI IN A NEW PET FOOD AND SUPPLIES STORE IN UNITS #'S 108 & 109.   EXISTING SERVICE, NEW PANEL, CIRCUITS & LOADS. PC IS FOR POWER & ENERGY.  BUILDING PCIS# 09016-10000-21432.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10503	15041-10001-17391	15857 W STRATHERN ST	91406	6	189B141    30	2206005023	C4-1VL, M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.21581	-118.47928	((10/27/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 8.  CHANGES INCLUDE REVISIONS TO THE SLD, REVISING LIGHITNG AND RELOCATING EQUIPMENT.  THIS IS PLAN CHECK ONLY.  FULL PC FOR POWER AND ENERGY. EXPANSION AND REMODELING OF AN EXISTING COMMERCIAL BUILDING. TOTAL SQ. FT.96,554 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10504	12041-20000-03151	17710 W ROSCOE BLVD	91325	12	192B129   324	2101001001	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM			PC Info Complete	08/27/2012 12:00:00 AM	ADDRESS	34.22072	-118.51902	Install new service and panels for CHANGE OF USE AND OCCUPANCY FROM (E) RESTAURANT (A-2 OCCUP) TO (N) RETAIL (M OCCUP). WORK TO INCLUDE RE-STRIPING OF PARKING AREA. SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10505	14041-20000-05170	12695 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97727	-118.41529	Roof mounted PV system with 3KW AC USING TRANFORMERLESS INVERTER. THIS IS PART OF A SERIES SET OF SUBMITTALS. THIS PV SYSTEM TO INTERCONNECT TO COMMON SERVICE. THIS IS PROJECT 1 OF 3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10506	11041-10000-10231	5601 N VAN NUYS BLVD	91411	2	174B149   818	2244027001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00, 1285.00	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	PIN	34.17244487	-118.44939749	NEW single story, 13, 473 square feet RETAIL  BUILDING.  CVS PHARMACY - FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10507	16041-20001-27442	11442 W VICTORY BLVD	91606	2	180B169  1159	2335021011	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.18641	-118.38048	PLAN CHECK ONLY, SUPPLEMENTAL FOR CHANGES TO APPROVED SET. CHANGES TO SINGLE LINE DIAGRAM, CHANGING ALL UNIT PANEL FEEDERS FROM COPPER TO 2/0 AL AND ALL UNIT FEEDER GROUNDS TO #4 AL. CLOUDED DELTA 3 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10508	16041-10000-43765	15301 W VENTURA BLVD	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.15411	-118.46654	PC for enrgy only. TI to exiisting restaurant (Jersey Mikes). Installing 2 new panels, new lighting and receptacles. Total sqft = 2077	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10509	19041-20000-48647	21600 W OXNARD ST Ste 2000	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.179	-118.6002	Power and lighting for (E) commercial space TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10510	18041-10000-40822	4911 S MAIN ST	90037	9	111A203   253	5110019027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	33.99789	-118.27415	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10511	18041-10000-42795	13836 W SATICOY ST	91402	6	186B153    40	2214023002	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.20991	-118.43457	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10512	17041-20002-18550	21004 W BALTAR ST	91304	3	189B109   263	2109009023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	34.21662	-118.59082	Revisions to approved set.  Revised feeder rating and 75 deg C termination rating.  $0 permit fee due to State Senate Bill SB 1222.  (((PV1. Install roof mounted pv system sized 11.3kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10513	18041-10000-41825	1750 N GLENDALE BLVD	90026	13	144A209   317	5423005024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.20	Electrical	Electrical	Apartment			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	02/03/2023 12:00:00 AM	ADDRESS	34.08713	-118.25942	Plan chekc for a fire alarm system located in a 4-story and 70-unit apartment building with (196) fire alarm unit, (6) power supplies, and (1) fire alarm panels.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10514	12041-10000-14738	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	07/30/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	Plan check power and energy for existing Macy's store TI from 1st floor thru 3rd floor. New lighting and new loads exceeding 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10515	16041-10000-03709	1074 W 39TH PL	90037	8	117B197  1014	5037021002	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Expired	03/12/2018 12:00:00 AM	ADDRESS	34.01402	-118.29397	PV1, ROOF MOUNTED SOLAR SYSTEM TO A TRIPLEX BUILDING. (12) MODULES AND (1) 3.0 KW INVERTER. TOTAL SIZE IS 3.0KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10516	19041-10000-45164	445 S FIGUEROA ST 10TH FL	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	ENERGY PLAN CHECK ONLY.  AREA OF SCOPE IS 360SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10517	13041-20000-21003	2455 E WASHINGTON BLVD	90021	14	118-5A219   1	5168010919	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	34.01874	-118.22808	New commercial core and shell building.  200 amp service.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  <<<Service size is actually 2000 amp, Plan Check for Power and permit fees are on supplemental application>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10518	10041-10000-12443	1400 N SPRING ST	0	1	136-5A217  83	5409004007	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	PIN	34.06640655	-118.23243996	additional 10 ckt and one panelfor EMERGENCY LIGHTING. 1 STORY BLDG.	N	N	Express Permit	06/10/2024 12:00:00 AM
10519	15041-20000-09008	25975 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	33.78721	-118.29774	Power plan check only.  Replacing main service switchboard and panelboards in existing MEDICAL space.  All existing loads to be reconnected.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10520	16041-20000-22395	800 S FIGUEROA ST Suite 1060	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	Plan check for Title 24 only. Project site is the 10th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,617 sq. ft.Note: Building application has been created under 16016-10000-14622	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10521	14041-20001-02120	10130 N VALJEAN AVE	91343	12	204B137   637	2678002006	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.25485	-118.48701	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10522	11041-10000-03996	515 S FLOWER ST 10TH FL	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10523	17041-10000-19966	1101 E 14TH ST	90021	14	123A211   364	5132017001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.02949	-118.24876	Installation of new fire alarm system in existing warehouse and office building.  Total system size = 13 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10524	16041-10000-28879	11837-11847 W KIOWA AVE 1-29	90049	11	129B145  1129	4265015039	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			08/15/2016 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.0491	-118.46531	Plan cehck for POwer and Energy on New 4-story, 29-unit, apartment over 1-level of  subterranean parking. 1600 MS.  120/240 3-phs, 4W. Total area: 11000sq.ftB# 16010-10000-00545	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10525	11041-20000-11779	20355 W SORRENTO LANE Building-13	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Public Safety Only			06/08/2011 12:00:00 AM	06/08/2011 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.27828	-118.57751	Plan check new fire alarm system for apartment building 13	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10526	17041-20000-20089	14731 W ALBERS ST	91411	4	174B149  1043	2249014007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.17046	-118.45423	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (13) AC PV modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10527	15041-20000-42890	853 E FLOWER AVE	90291	11	111B145   524	4243017014	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.00167	-118.46524	Plan check for PV roof mounted system. System size: 6.0kWac with 28 modules and 1 inverter(6.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10528	17041-20000-43680	7957 N SANGAMON AVE	91352	2	189B181   194	2403013006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.21599	-118.34739	ENERGY STORAGE SYSTEM + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.85KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10529	12041-10001-03784	7311 N FIGUEROA ST Building B	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	34.13623	-118.18853	CHANGES TO APPROVED SET OF PLANS UNDER PC # 12041-10000-03794. DELTA 4 CHANGES ONLY ARE CLOUDED. CHANGES INCLUDE OUTDOOR LIGTHING OF BUILDING B  AND CHANGE OF THE INTERIOR OF BUILDING B TO CORE AND SHELL. ORIGINAL SET OF PLANS WILL BE DROPPED OFF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10530	19041-20000-07491	14761 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.17768	-118.45503	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 10,089 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10531	19041-20000-43564	3645 N LOWRY ROAD	90027	4	154-5A203 149	5592010004	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.1178	-118.27765	Plan check for Energy Storage System install into existing PV system. Total energy system size: 40.5KWh with 3 Tesla PowerWall 2.0, 2 sub panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10532	14041-10000-00752	11221 W PICO BLVD	90064	5	123B153   146	4322023038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.03594	-118.43757	T24 PART 6 ENERGY LIGHTING ADDITIONS TO (E) SMART & FINALS BUILDING. SCOPE OF WORK < 400A. PROJECTED AREA IN SCOPE OF LIGHTING WORK ~ 850 SQ FT. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10533	12041-10000-27401	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	PIN	34.03245819	-118.45766562	INSTALL A NEW 277/480V, 3ph, 4W, 5,000 AMP SERVICE FOR TWO NEW BUILDINGS (PARKING STRUCTURE AND BUILDING #4).  THERE ARE NO CONNECTED LOAD AT THIS TIME. ALL FUTURE TI's REQUIRE COMPLETE ELECTRICAL PLAN CHECK AND PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10534	18041-20000-26131	235 S HARVARD BLVD 1-48	90004	10	135B193    53	5517014019	R3-1	Central	Wilshire	Wilshire Center-Koreatown		2114.20	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.0701	-118.30428	Plan check for a PV2 roof-mounted PV system. System size is 44.20 kWdc/38.86 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (130) modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10535	14041-20001-00985	6500 W 84TH ST	90045	11	096B165    72	4108012019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	33.96282	-118.40179	((expedite fees))pv1 single family dwelling. total system size 6kw ac using 2 stransformerless inverters nonstandard plan. total of 18 modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10536	11041-20000-23441	10813 N ZELZAH AVE	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	08/03/2012 12:00:00 AM	ADDRESS	34.26646	-118.52366	T.I. to existing retail space.  Install new 600A switchboard, subpanels, and branch circuits.  Install general/emergency lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10537	18041-30000-15434	2029 S CENTURY PARK EAST 5th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Issued	04/26/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site are the corridors on the 5th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 3,110 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10538	12041-10002-30784	12751 W MILLENNIUM B	90094	11	102B161  1235	4211033050	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/21/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	REVISION TO APPROVED PLANS, DELTA 38. CHANGED FIXTURE TYPE FROM FLUORECENT TO LED, REVISION OF ENERGY CALCS. TI 24(((PLAN CHECK POWER AND ENERGY FOR BUILDING B. FIRST LEVEL RETAIL WITH 3 STORY OF 120 UNITS RESIDENTIAL BUILDING ON TOP OF COMMON SUBTERRANEAN PARKING GARAGE. TWO SERVICE SUPPLYING BUILDING. SITE LOCATED IN METHANE ZONE. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10539	17041-10000-23226	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			Reviewed by Supervisor	08/02/2017 12:00:00 AM	ADDRESS	34.05855	-118.23671	Plan check for power.  Install (2) 500 amp 480 volt 3 phase circuits to feed new chiller on rooftop.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10540	18041-10000-42849	1822 S OVERLAND AVE	90025	5	129B157   477	4321004026	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			11/08/2018 12:00:00 AM	09/22/2021 12:00:00 AM		Issued	09/22/2021 12:00:00 AM	ADDRESS	34.05078	-118.4321	FULL PC FOR NEW 16 UNIT APARTMENT BLDG; 6 STORIES HIGH, OVER TWO STORIES OF BELOW GRADE PARKING NEW 1200A SERVICE, T24 INCLUDED. 3 TYPICAL UNIT TYPES, 4 UNIQUE TYPES.SQFT (13852)BLDG PERMIT #18010-10000-05347	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10541	16041-30000-19313	11280 W OLYMPIC BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM			PC Approved	06/03/2016 12:00:00 AM	ADDRESS	34.03823	-118.44069	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,436 sq. ft.Note: Building application has been generated under 16016-30000-09967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10542	18041-20000-47953	18521 W SAN FERNANDO MISSION BLVD	91326	12	210B125   353	2717010020	RE11-1	North Valley	Northridge	Northridge West	YES	1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.27199	-118.53701	Plan check for PV roof mounted system, system size: 12.3KW DC, 10KW AC 41 PV Modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10543	17041-20001-39148	18681 W HILLSBORO ROAD	91326	12	207B121   586	2728030013	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.26275	-118.54005	PV1. Install 11.02 kW DC roof mounted grid tied PV system.  (38) modules with 10 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10544	18041-10000-25164	13754 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.30932	-118.43311	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10545	16041-10001-42964	5533 W VIRGINIA AVE	90038	13	144B193   513	5536008015	R4-1VL	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM			PC Info Complete	05/07/2020 12:00:00 AM	ADDRESS	34.0919	-118.31033	SUPPLEMENTAL TO APPLICATION#: 16041-10000-42964. MAJOR REVISION TO THE DESIGN AND CHANGE WORK DESCRIPTION TO 5-STORY 24 UNIT APARTMENT BUILDING. SCOPE INCLUDES NEW 1200A 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, REVISING LIGHTING FLOOR PLANS, PANEL SCHEDULES, LOAD CALCULATIONS, AND TITLE 24 CALCULATIONS. B#16010-10001-05541NOTE PERMIT TO BE PULLED UNDER THE MASTER APPLICATION PCIS#16041-10000-42964 UNDER INSPECTION FOR NEW SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10546	15041-20000-11649	1030 N WESTERN AVE	90732	15	021B193   140	7445010041	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	33.75267	-118.30869	Plan check for Title 24 only. Project scope is a tenant improvement to an existing commercial space (restaurant). Total lighting area = 2,564 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10547	19041-10000-05442	800 W 6TH ST 980	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	PLAN CHECK FOR TITLE 24 ONLY FOR - T.I. CONSTRUCTION OF NEW NON-BEARING PARTITIONS, REWORK EXISTING ACOUSTIC CEILING, REWORK ELECTRICAL LIGHTING & POWER DISTRIBUTION, NEW FLOOR & WALL FINISHES. TOTAL AFFECTED AREA = 1396 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10548	16041-10000-14840	14757 W ARMINTA ST	91402	6	189B149   482	2210021009	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.21385	-118.45492	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 600A SERVICE FOR AN EXISTING WAREHOUASE BUILDING; NEW 600A 120/240V 1 PHASE 3WIRE MAIN DISTRIBUTION BOARD, 3 NEW 200A SUBPANEL, AND  NEW LOAD EQUIPMENT FOR PANELS 'P1' AND 'P2'. TOTAL AFFECTED AREA IS 10214 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10549	19041-20000-48471	4365 N TUJUNGA AVE	91604	2	165B173   458	2365015024	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.14921	-118.3792	PV3 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 7.26 KW DC/7.6 KW AC. SCOPE OF WORK CONSISTS OF (22) PV MODULES WITH OTPIMIZERS AND A 7.6 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10550	18041-20001-24346	3601 S TROUSDALE PKWY 3rd Floor	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM			PC Approved	11/09/2018 12:00:00 AM	ADDRESS	34.02017	-118.28558	Revisions to approved set.  Change of lighting system. (((Tenant improvement to expand lounge area.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10551	16041-10000-33207	2269 E CENTURY BLVD 101-301	90002	15	091-5A217   1		RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	33.94667	-118.23209	PC for power only for a New 3 STORY 14 UNIT APARTMENT B3 BUILDING (Bldg. 5 of 8). Scope includes a new 600A 120/208V 3 phase 4 wire service/distribution board. One plan is submitted for multiple apartment buildings. B#16010-10000-02988	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10552	14041-10001-31771	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	CCD1 AND CCD2 CHANGES TO PERMITTED SET OF PLANS: UPDATED LIGHTING SYSTEM; SHIFT LOADS TO OTHER PANELS(((((((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR RESTAURANT IN THE SHERATON AT THE BLOC; NOTE THAT THE OWNER IS DEVELOPING THIS SPACECORE AND SHELL PERMITTED ON 14041-10000-14771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10553	15041-10000-20853	889 S FRANCISCO ST	90017	14	129A207   155	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			07/01/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.04769	-118.26404	New fire alarm system for the Metropolis Residential Tower.  1,406 device system with 6 FACPs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10554	13041-10000-15126	20000 S WESTERN AVE	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	33.85008	-118.30908	This is a one story shell to be come offices, warehouse, light industrial. Power, lighting, hvac, title 24 and emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10555	18041-10001-20599	1620 S REDONDO BLVD	90019	10	126B181   264	5067002048	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM			PC Info Complete	08/28/2018 12:00:00 AM	ADDRESS	34.04442	-118.35048	Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling. Plan Check ONLY. Permit was issued under: 18041-90000-20599	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10556	13041-10000-08286	5816 N WILLIS AVE	91411	2	174B149   226	2244010009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.17629	-118.45504	PV1 SINGLE STORY. 29 MODULES AND 1 INVERTER, 7.11 KW. ROOF MOUNTED SOLAR. [SOLAR MODULE: YINGLI ENERGY- YL245P-29B 245W.] [ENPHASE ENERGY: M215-60-2LL-S22/S23 (240V)]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10557	12041-20000-14280	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Changes from previously approved plans.  Bulletin 186 and 190.Note: Permit issued under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10558	13041-10000-24044	7658 N LENA AVE	91304	12	189B097  1181	2014020023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.21	-118.62578	PV1. ROOF MOUNTED SOLAR ARRAY. CENTRAL INVERTER. SYSTEM SIZE: 6.615 KW. 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10559	18041-20001-24046	8425 N ZEILER AVE	91402	6	192B157   481	2637014057	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2018 12:00:00 AM			PC Approved	07/30/2018 12:00:00 AM	ADDRESS	34.22364	-118.42564	Expedite per applicant request Plan check for PV roof mounted with battery back up system, system size: 7.6kW with 12 modules, 1 inverter(7.6kW) and LG Chem REU 10H.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10560	12041-20000-03644	8900 N DE SOTO AVE	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	05/10/2012 12:00:00 AM	ADDRESS	34.23162	-118.58832	laboratory room energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10561	13041-20000-10274	20450 W LASSEN ST	91311	12	201B109   131	2748006030	C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03, 1133.22	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.24983	-118.57925	"Full plan check for gas station. Changes to outdoor lighting and dispenser pumps. Hazardous area, all lighting fixtures are outside of hazardous area.  ""COMPLY WITH DEPARTMENT ORDER effective date 02/26/2004. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10562	14041-10002-15434	3640 W WILSHIRE BLVD	90010	10	132B193    62	5093019018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.06145	-118.30446	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1. CHANGE TO CONCRETE PAD FOR GENERATOR AND SWITCHGEAR REMOVED. THIS IS PC ONLY. PERMIT ALREADY COVEERED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10563	15041-10001-34205	1369 W PLAZA DEL AMO	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	33.82101	-118.30079	Install rooftop solar system 2.365 kW AC system. permit under 15041-90000-34205.Zero additional fees per CA senate bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10564	15041-10000-16398	659 S BROADWAY	90014	14	129A211   258	5144003040	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.04551	-118.2533	TI, TI-24 ONLY. NO CHANGE OF USE, NO NEW LOAD. RETAIL BURLINGTON COAT IN A HIGH  RISE BUILDING. LOCATION OF RETAIL IS IN THE 1ST FLOOR AND BASEMENT.  ALL PANELS ARE EXISTING TO REMAIN.  existing EMERGENCY PANEL IS FED FROM EXISTING GENRATOR.  LIGHTING WATTAGE PER CUT SHEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10565	14041-20001-10593	21031 W VENTURA BLVD 424	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM			PC Approved	05/12/2014 12:00:00 AM	PIN	34.16717222	-118.59179488	Plan check for Title 24 for changes to office lighting system.  Express permit obtained under 14041-90000-10593(((Office Tenant Improvement in Suite 424)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10566	14041-10001-32759	12655 W BEATRICE ST	90066	11	105B157   658	4211006017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	33.98007	-118.41764	ADD ONE GENERATOR, TWO UPS SYSTEMS AND THREE ATS TO EXISTING SWITCHGEAR. PERMIT FOR GENERATOR HAS BEEN PULLED UNDER APPLICATION#:14041-10000-32759. ADDITIONAL PERMIT FEES APPLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10567	11041-10000-08519	8734 S BELLANCA AVE	90045	11	096B169   844	4125018007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	33.95765	-118.38038	T.I.  AT CUSTOMER SERVICE CENTER BUILDING AT ENTERPRISE RENT-A-CAR.  CUSTOMER REQUESTS FULL PLAN CHECK.   NEW PANELS, X-FRMR, CIRCUITS, LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10568	18041-20000-27241	12105 W WATERFRONT DR STE B	90094	11	105B161  1199	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	33.98095	-118.40764	Plan check for power and energy first time tenant for a restaurant. Total area: 1500 sq ft.B# 18016 10000-18228	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10569	11041-20000-22308	970 W 190TH ST 5th floor	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM			PC Approved	10/18/2011 12:00:00 AM	ADDRESS	33.85812	-118.29302	energy plan check TI 5th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10570	14041-20000-25709	15566 W RAYEN ST	91343	6	195B141   882	2654015017	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM			PC Info Complete	07/23/2015 12:00:00 AM	ADDRESS	34.23174	-118.47244	PC FOR POWER AND ENERGY. NEW 31 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED. DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 NEC AND 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10571	11041-10000-04961	525 S FLOWER ST FLRS 1-3	90071	9	130-5A209 146	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	11/15/2011 12:00:00 AM	ADDRESS	34.05109	-118.25696	T.I.  NEW OFFICE BUILDING ON FLOORS 1 THRU 3.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10572	14041-20000-21386	12909 W MONTFORD ST	91331	7	213B161   463	2533023016	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.28075	-118.41391	PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 3.87kW(18) EnPhase M215-IG microinverters(18) Hyunday HiS-M250G pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10573	16041-10000-06846	2300 N ALTO OAK DR	90068	4	153B193   438	5587008042	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.11179	-118.31337	PV1, INSTALL 15.2 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(2) INVERTERS: SOLAREDGE SE7600A(44) MODULES: SUNPREME MAXIMA GXB 300W	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10574	11041-10001-00037	11677 W SAN VICENTE BLVD Ste #103	90049	11	132B145   518	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM			PC Approved	02/24/2011 12:00:00 AM	ADDRESS	34.05404	-118.46492	CHANGE OF USE FROM RETAIL TO BANK WITH RELATED INTERIOR TENANT IMPROVEMENTS. plan chk  for Title 24 compliance	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10575	19041-10000-14091	1721 N NORTH BROADWAY	90031	1	136-5A221 165	5447030006	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.07205	-118.22323	REPLACE INDOOR FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10576	11041-20000-00253	13131 W SHERMAN WAY Building A	91605	2	183B157    37	2327003053	CM-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.20136	-118.41904	New auto service center Building A (East Building) with 1000A service.   Core and Shell electrical plan check for power only.Note: Building B (West Building) is under 11041-20000-00255	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10577	17041-20000-11640	3959 W WILSHIRE BLVD B9	90010	10	132B193    31	5504027020	C4-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	34.06186	-118.31337	TI to (E) restaurant.  Plan check for energy.  1077 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10578	15041-10001-04736	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM			PC Approved	04/30/2015 12:00:00 AM	PIN	33.93847109	-118.41935625	PROVIDE PANELBOARDS, NEW LOADS ON EXISTING CIRUITS- EXISTING  SERVICE IS TO PROVIDE POWER TO PANELBOARDS MOUNTED ON EXISTING TRAILERS ( California approved.)(((((((((Installation of 3000A swbd/service only. Future use is for the new service to supply power to future loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10579	16041-10000-23185	921 S CROCKER ST #C-21	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.03582	-118.24984	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO CAFE  ON THE 1ST & MEZZANINE FLOORS. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1555 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10580	13041-10001-28770	3227 S MAPLEWOOD AVE	90066	11	114B149   275	4247006035	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.01051	-118.4523	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOF MOUNTED SOLAR SYSTEM. 2 STORY HOUSE. STANDARD CENTRAL INVERTER PLAN. (36) HANWHA # HSL60P6-PB-4-250TW(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10581	15041-10000-27181	6245 W WILSHIRE BLVD	90048	5	135B173   810	5510023048	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Info Complete	10/07/2015 12:00:00 AM	ADDRESS	34.06356	-118.36478	METHANE GAS DETECTION SYSTEM TO A MIX USE, HIGH RISE BUILDING. (1) CONTROL PANEL, (1)  FIRE ALARM PANEL, (27) DEVICES. HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10582	13041-20000-23541	19030 W TRIBUNE ST	91326	12	207B121   166	2718014006	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.26654	-118.54742	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.6 KW AC. USING 40 MODULES AND ENPHASE MICROINVERTER. NONSTANDARD PLAN. 4 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10583	19041-10000-05119	523 W 6TH ST # 1228	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.04864	-118.25484	Tenant improvements in exisitng offices-new lighting and powerPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10584	19041-10000-49782	1255 N CHEROKEE AVE	90038	4	144B185   173	5532003028	R3-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.0941	-118.33541	NEW ROOF MOUNTED PV SYSTEM WITH 136 PV TILES (TESLA SRV 3) AND 2 CENTRAL INVERTERS( DELTA SOLIVIA 5.2 EACH )  ON A SINGLE FAMILY HOME. SYSTEM SIZE IS 7.95 KWdc AND 10.4 KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10585	15041-10001-02682	110 E 22ND ST	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	33.72668	-118.27682	CHANGE TO APPROVED SET. REVISE SHORT CIRCUIT RATINGS AND ADDITION OF AIR CHILLER AND MILLING MACHINE. ALL CHANGES NOTED ON PLANS DELTA 2 REVISION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10586	13041-10002-01885	380 WORLD WAY Space T50	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	][][ Delta 3 revisions- replaced track lighting with other track system with lower wattage; compliance forms were updated; PLANS FOR PC# 13041-10001-01885 WERE APPROVED, HOWEVER, WAS LOST BY. 13041-10002-01885 WAS COMPARED TO 13041-10002-01885 PLANS, AND NO CHANGES WERE MADE FROM THE 13041-10001-01885 SERIES.  ][][]LAX  Thomas Bradley International  Terminal level 4. space T50-RPROPOSED 1470 SQFT.  TENANT IMPROVEMENT  FOR RETAIL CONCESSION  SPACE (kitson).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10587	18041-10000-07828	1501 W SUNSET BLVD A;B;APTS	90026	13	139-5A209 235	5419027007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	08/08/2022 12:00:00 AM	ADDRESS	34.07605	-118.2552	REMODEL AND CHANGE OF USE FROM 2-STORIES  OFFICE WITH ATTACHED GARAGE TO RESTAURANTS ON THE 1ST FLOOR AND 5-UNITS APARTMENTS ON THE 2ND FLOOR.FEE FOR SMOKE DETECTORS WERE NOT INCLUDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10588	18041-10000-01679	4333 W WILSHIRE BLVD	90010	4	132B189    17	5505029012	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	34.06197	-118.32252	Energy plan check for modification in place located in a commercial building, Total are is 6,380 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10589	16041-10000-21390	4744 N HASKELL AVE	91436	5	168B141   579	2261029003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.15645	-118.47467	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH OPTIMIZERS. (51) MODULES LG320N1C-G4 AND (51) OPTIMIZERS SOLAR EDGE PV (2) 7.6KW SOLAR EDGE INVERTERS. TOTAL SYSTEM SIZE IS 15.2KW.NOTE: Fees are $0 due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10590	13041-20000-28198	601 S FIGUEROA ST	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			Corrections Issued	10/10/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	PC FOR T24 ENERGY ONLY. TOTAL AREA 4255 SQ FT. NEW LIGHTING. RENOVATION OF OFFICES. LOW LOAD.***SCOPE OF WORK CHANGED, THIS PLAN CHECK IS ABSOLETE.***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10591	19041-10000-06142	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	33.96577	-118.42406	PC FOR POWER ONLY. SCOPE INCLUDES NEW MEDIUM VOLTAGE FEEDERS, AND NEW 1600A DISTRIBUTION BOARD FEEDING EXISTING BUILDING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10592	15041-20000-41726	10526 W DUBNOFF WAY BLDG A&J	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Approved	02/01/2016 12:00:00 AM	ADDRESS	34.18656	-118.36106	Plan check  only for significant redesign for 1600A service, 2,500A and 1,000A service equipment (7) 225A panel.  Plans submitted per inspector request.  Reffer to Permit #: BLDG-A 13041-20000-31266BLDG-J 13041-20000-31273BLDG-H 13041-20000-31274BLDG-G 13041-20000-31275	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10593	18041-10000-38828	4575 E HUNTINGTON DR SOUTH	90032	14	142-5A231  88	5213013904	PF-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.08529	-118.18677	NEW FIRE ALARM SYSTEM IN FIRE STATION #47.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10594	19041-20000-23172	21300 W VICTORY BLVD ste 130	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.18813	-118.59618	ti to an existing commercial building (high rise).  replacing existing lighting with new LED.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10595	17041-10000-44061	2111 N SICHEL ST	90031	1	136-5A223  29	5204018001	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Issued	12/07/2017 12:00:00 AM	ADDRESS	34.06975	-118.21312	PC for replacement of FACP  and addition of smoke detector to existing fire alarm system in school building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10596	19041-20000-20031	8606 W WONDERLAND AVE	90046	4	153B169   821	5563009041	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.11301	-118.38222	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.95KW DC/5KW AC/4.2KW AC CEC. SCOPE OF WORK INCLUDES (15) PANASONIC PV MODULES WITH P400 OPTIMIZERS, AND A SE5000H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10597	10041-10000-19383	8489 W 3RD ST	90048	5	138B173   683	5511013021	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM			Corrections Issued	09/29/2010 12:00:00 AM	ADDRESS	34.07345	-118.37542	T-24 lighting plan check for remodeled tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10598	17041-10000-20238	700 N HENRY FORD AVE	90744	15	030B213   140	7440002035	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Info Complete	06/15/2017 12:00:00 AM	ADDRESS	33.77971	-118.24145	PC for power for new trasformer and 200 A disconnect switch in hazardous location (methane zone).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10599	16041-30000-10296	8621 S SEPULVEDA BLVD	90045	11	096B165   638	4122001007	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Issued	04/28/2016 12:00:00 AM	ADDRESS	33.95931	-118.39651	Title 24 plan check only.  Total area = 1,013 sq. ft.      T.I. to existing department store.  New lighting in dressing rooms including new emergency lighting.  New receptacles in fitting rooms and cash counter area.  Building permit #16016-30000-06122	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10600	13041-20000-00418	10506 W SANTA MONICA BLVD 1-3	90025	5	132B157   982	4317003002	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.0551	-118.4269	New 3rd Floor Addition to an existing mixed use (commercial/residential) building.  Full Plan Check.  Site is a Methane Zone.  ALL conductors or conduit are to be run above grade, per Engineer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10601	11041-20000-00573	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Closed	02/25/2013 12:00:00 AM	ADDRESS	34.30363	-118.45814	Replace 1200amp service, switchboard, feeders, and transformer.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10602	19041-10000-53274	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2623.01	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	12/05/2022 12:00:00 AM		Issued	12/05/2022 12:00:00 AM	ADDRESS	34.08469	-118.4849	Full Plan check for a new construction  with new service rated at 1000A 480/277V 3phase 4wire. New lighitng and power. Total sqft = 150,600.fire alarm not included in this plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10603	14041-20001-17630	7341 W FOOTHILL BLVD	91042	7	202-5A199  94	2568010004	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.25075	-118.29184	[[[[11/26/14 CHANGES TO APPROVED SET OF PLANS. CHANGE OF SERVICE TO 3 PHASE 600 AMP SERVICE. INSTALLATION OF A NEW ELEVATOR]]]]]TI to (E) commercial building for medical office tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10604	16041-10000-31215	401 W WESTMONT DR	90731	15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	33.76342	-118.2899	Permit fee is $0.00 due to Senate Bill 1222.PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3069.52KWdc / 2320KWac. FEED IN TARIFF.(8296)MODULES-SUNPREME MAXIMA-GXB-370(29)INVERTERS-DELTA ELECTRONICS M90U-122(1)4000A SWITCHBOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10605	13041-10000-10691	200 WORLD WAY T 2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			Not Ready to Issue	04/25/2013 12:00:00 AM	ADDRESS	33.94558	-118.4039	13041-10000-07089PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS FOR TENANT IMPROVEMENT AT LAX TERMINAL 2. NOTE; ALL TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER. NEW WORK < 400A.	N	N	Express Permit	06/10/2024 12:00:00 AM
10606	12041-10000-19252	2001 S WESTWOOD BLVD	90025	5	129B153   995	4323003013	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM			PC Approved	08/15/2012 12:00:00 AM	ADDRESS	34.04645	-118.43415	title 24  for a retail, one story , no e- lites.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10607	18041-10000-17074	816 N GLENMERE WAY	90049	11	138B137   457	4426028017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/03/2018 12:00:00 AM	ADDRESS	34.07243	-118.4922	PV1. ROOFMOUNTED SOLAR SYSTEM USING MICRO INVERTERS AND ENERGY STORAGE SYSTEM. SYSTEM SIZE: 9 KW + ENERGY STORAGE 26KWHFEES ARE $0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10608	14041-10002-05555	3150 W WILSHIRE BLVD SUITE A	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	(((5/16/2014- Changed 1 light fixture, it has been clouded. Energy calculations to be verifited)))(((4/7/2014- CHANGES MADE TO APPROVED SET. CHANGES TO LIGHITNG ONLY. PERMIT TO BE PULLED ON THE MASTER APPLICATION)))PLANCHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR STARBUCKS. HIGHRISE. SUITE A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10609	18041-20000-25006	1500 S CENTRAL AVE	90021	14	121-5A211 236	5130014025	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Issued	07/12/2018 12:00:00 AM	ADDRESS	34.02704	-118.24799	"New emergency lighting for second and third floor of commercial building.""COMPLY WITH DEPARTMENT ORDER effective date11/23/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10610	19041-20000-49160	2100 N HERCULES DR	90046	4	150B177   106	5569013060	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Expired	11/08/2023 12:00:00 AM	ADDRESS	34.10804	-118.36321	PV1 PLAN CHECK FOR NEW PV, SYSTEM SIZE IS 10.585 KW DC/9 KW AC. SCOPE OF WORK CONSISTS OF (29) PV MODULES WITH A 9 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10611	15041-10000-30303	11445 N PETIT AVE	91344	12	213B133   760	2682005011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	PIN	34.27863511	-118.49898739	Change to approved set by adding an additional AC disconnect to the PV1 system, and reducing the number of PV module from (23) to (21).  Original permit number is under 15041-10000-22477 with following work description: (((Install 7.5 kW DC PV1 roof-mounted, utility-interactive PV system.)))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10612	17041-10000-08008	2326 N HOLLYRIDGE DR	90068	4	151-5A191 115	5586018010	RE9-1	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	04/08/2017 12:00:00 AM	ADDRESS	34.11034	-118.3187	PC FOR PV SYSTEM SFD. TOTAL SYSTEM SIZE 4.8KW AC USING 20 MODULES MICROINVERTER SYSTEM. SYSTEM IS ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10613	11041-20000-01480	12130 W VENTURA BLVD	91604	2	162B165   169	2369014005	C2-1VL, R4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Apartment			01/25/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	04/22/2011 12:00:00 AM	ADDRESS	34.14334	-118.39624	T.I. for existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10614	19041-20000-31765	7800 S AIRLANE AVE	90045	11	099B169   445	4106025017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	33.96869	-118.38978	Install 27 kWh energy storage system and associated distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10615	17041-10000-15972	4155 N VERDUGO ROAD	90065	14	157-5A217 144	5459025013	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	34.12651	-118.23218	PC FOR ENERGY ONLY. TITLE- 24 FOR A COFFEEE SHOP.INSTALLING NEW LIGHTS AND RECEPTACLESTOTAL AFFECTED AREA 494 SQ.FT.THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER 17041-10000-09207B#16016-10000-24540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10616	12041-10000-30170	909 W TEMPLE ST BLDG A	90012	9	133-5A211  74	5161001036	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Apartment			12/14/2012 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.06102	-118.24942	New 287 unit apartment building (15 typical units).  Mixed used with 1st floor being for commercial use and 6 floors on top for residential use.  One level of subterranean parking and 2 above grade.  Fire alarm plans are not included in the submittal.  A fire alarm variance must be filed.  BLDG A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10617	11041-20000-04524	626 S ALVARADO ST 1-79	90057	1	133-5A203 184	5141001019	C2-2	Central	Westlake		YES	2089.03	Electrical	Electrical	Public Safety Only			03/08/2011 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.05869	-118.27519	PLAN CHECK FOR NEW INSTALLATION OF FIRE ALARM SYSTEM FOR MIXED USE APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10618	17041-20001-00737	8242 N CELIA PL	91406	6	192B133   525	2204001043	(Q)RD5-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	PIN	34.22030223	-118.50784381	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10619	18041-10000-32284	9545 W WENTWORTH ST	91040	7	207B185   137	2549004026	A2-1, M1-1, P-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.26418	-118.34013	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10620	19041-10001-05259	9333 N MELVIN AVE	91324	12	198B117   121	2761036046	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM			PC Approved	05/06/2019 12:00:00 AM	ADDRESS	34.24024	-118.56026	SUPPLEMENTAL FOR FEE EXPEDITE - WITHDRAWN PER APPLICANT'S REQUEST PLAN CHECK FOR 52KVA ROOF MOUNTED PV SYSTEM CONSISTING OF 4 INVERTERS((3)FRONIUS 10.0 AND (1)FRONIUS 12.0) WITH 174 MODULES(TRINA TSM-DD114A(11)340W)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10621	19041-10000-00182	3475 S STONER AVE	90066	11	117B153  1102	4249015003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	02/09/2019 12:00:00 AM	ADDRESS	34.01339	-118.43259	PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H) WITH 18 MODULES USING P400 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10622	19041-20001-02047	8352 N COOPER PL	91306	3	192B109   955	2780005077	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Issued	03/12/2019 12:00:00 AM	ADDRESS	34.22201	-118.58696	3/12/2019changes to an approved set of plans.  changes to consolidate (2) ESS into (1) panel.plan check for power only.((((addition of (2) tesla batteries 5KW each to an existing pv system.  plan check for power only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10623	18041-10001-32668	915 N SYCAMORE AVE	90038	4	144B181   746	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.08769	-118.34291	CHANGES TO TITLE 24 APPROVAL AND SOME REVISIONS TO POWER PLANS- INSTALLED LIGHTING WATTAGE CHANGED FEW CIRCUITS ADDED  AS-BUILT- SET OF PLANS(((((((((REMODELING OF WAREHOUSE RETAIL/OFFICE SPACESADDED LOAD IS LESS THAN 400APLAN CHECK IS FOR TITLE 24 AND 1 EMERGENCY CIRCUIT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10624	19041-20000-25581	8758 N DEMPSEY AVE	91343	12	195B141   554	2672012043	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.22999	-118.47735	Plan check for a PV1 roof-mounted PV system. System size is 12.96 kWdc/11.01 kWac-CEC and consists of (36) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10625	10041-20004-14422	6201 W HOLLYWOOD BLVD	90028		148-5A189  54	5546031001	[T][Q]C4-2D-SN		Hollywood	Hollywood United			Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.1018	-118.32461	Modification to approved set of plans.  Change to lighting, new circuits, panels.<<<<NEW MIXED USE APARTMENT BUILDING>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10626	15041-10003-01360	200 WORLD WAY TERM 2-DEPT LEV 3	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/23/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Change to approved set by adding a inverter for all emergency light, and (1) circuit for the metering system.all changes are under delta 4 only.(((Revisions to approved set.  Lighting fixture schedule and lighting design revised. (((TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 DEPT  LEV 3  SPACE 223PLAN CHK IS FOR TITLE 24))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10627	18041-10000-46976	12100 W CLARKSON ROAD	90064	11	120B153  1233	4257015042	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.0213	-118.44337	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.60KWdc / 6.40KWac. (20)MODULES-SUNPOWER SPR-X22-360-D-AC(20)MICROINVERTERS- ENPHASE IQ7X-96-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10628	14041-10001-35178	1786 N NORTH SPRING ST	90031	1	138A219   143	5447026002	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Issued	02/06/2017 12:00:00 AM	ADDRESS	34.07128	-118.22282	Change to approved set:1. Change from UPS to Overhead per LADWP2. Voltage class change3. Panel schedule changeVerify homerun.<<Full plan check for TI to (E) commercial building, conversion from light industrial to commercial office .>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10629	19041-10000-11248	950 S BROADWAY	90015	14	126A209    41	5139002022	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Issued	07/31/2019 12:00:00 AM	ADDRESS	34.04113	-118.25698	Full Plan check for TI of Existing 7-story building. 2 -existing service 600A (1 service is 1ph, 2nd is 3ph). 240/120V. area of scope 23,256SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10630	16041-10000-25317	11100 S HINDRY AVE	90045	11	087B173    56	4129038005	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	33.93409	-118.37222	Plan check for T-24 only. Remove HID fixtures and replace with new LED fixtures. Total affected area: 11,728 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10631	19041-10000-52083	660 S FIGUEROA ST 21ST FLOOR	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	10/12/2020 12:00:00 AM		Issued	10/12/2020 12:00:00 AM	ADDRESS	34.04953	-118.25947	T-24, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 828.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10632	16041-10000-41824	1262 E 40TH PL	90011	9	115-5A211 177	5114035011	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.01008	-118.25278	PV SYSTEM USING CENTRAL INVERTER 3.8 KW WITH 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10633	16041-20000-10180	7227 N IRVINE AVE	91605	2	183B169    38	2316030036	R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.20201	-118.3857	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.86 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10634	19041-20000-03947	1040 N LAS PALMAS AVE	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	Plan check for power only. Project site is an existing commercial building. Project scope is the replacement and relocation of an existing medium voltage sub-station (kVA rating remains the same). No new load added as part of this scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10635	13041-10001-27138	5127 E SAN RAFAEL AVE	90042	1	153A225   268	5469004029	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.11338	-118.20471	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 4.5 kW. TRANSFORMERLESS INVERTER. 2 STORY.(23) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-5000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10636	16041-10001-44030	10250 W SANTA MONICA BLVD #1905	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	1st revision to an approved plan for 1st time tenant Caudalie Space #1905. Scope: adds 2 branch ckt for sales receptacles; update lighting fixtures; update load calculation; update T24 info.  Changes are noted under Delta-3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10637	16041-10006-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			Plans on Hold	10/17/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	***10/17/18: Plan's on hold per IA, plan's not found***DELTA 15 CHANGES ONLY. <<<<PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT.>>>>>>>>>> BUI;DING APPLICATION 16010-10000-04147	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10638	17041-10000-21777	517 W 112TH ST	90044	8	087A201    49	6075024025	C2-1VL, R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.93299	-118.28352	TItle 24 plan check.  Replace existing fixtures with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10639	16041-20000-15021	20790 W NORDHOFF ST Unit 2	91311	3	198B109   218	2780001059	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	T. I. - NEW NAIL SALON WITHIN EX. CORE & SHELL BLDG (14010-10000-00744) & ROOF TOP EQUIPMENT.  FIRST TIME TENANT - PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10640	17041-10000-31946	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC for power for new chiller equipment, pump equipment, cicuits and panel. Providing power to panels MCP-HD, MCP-HC, MCP-HA  wich feeds chiller equipment inside manufacturer prefabricated utility room modules  shown in E1.1. Providing power to pump modules located inside manufacturer prefabricated pump room module shown on E2.0. B#17020-10000-02229	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10641	13041-10001-28836			11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	((((((((((((((((((((((((((    4-2-14 MZ.   relocating panel 4T22H, 75 kva xfmr, and water heater.  xfmr , water heater and panel relocated no permit rquired M.Z.))))))))))) FIRST TIME TENANT. POWER AND ENERGY PLAN CHECK. LAX BRADLEY TERMINAL. MASTER PLAN CONNECTED LOAD 72.80 KVA @ 480/277. LOAD FROM 3N1BC1 : 175.57 KVA @ 480/277. 3NMBC1 @ 306.58 KVA @ 480/277. FEES SHALL BE VERIFIED BY PLAN CHECKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10642	12041-20000-30755	4409 N PAMPAS ROAD	91364	3	166-5A105 219	2190007023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2012 12:00:00 AM	01/10/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.15048	-118.60063	Photovoltaic system on roof of a single family dwelling using tranformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10643	11041-20000-22964	17736 W MARTHA ST	91316	12	174B129   768	2159002079	R1-1	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.17298	-118.51987	Install Enphase inverter  PV system on the roof of single family dwelling and garage.  The wiring from the garage to the house is an overhead span, and shall comply with CEC 225. Three enphase branches.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10644	14041-20000-15099	7402 S DUNBARTON AVE	90045	11	102B161   139	4110025059	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	33.97319	-118.4101	PV1.  Install 4.95 kW roof-mounted, utility-interactive PV system.  Microinverters: Enphase M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10645	14041-10000-27276	15622 S VERMONT AVE	90247	15	072B197   334	6120004011	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	33.88918	-118.29142	INSTALL 11.44 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. 3 STRINGS.(44) MODULES: WINIACIO WSP-260P6(44) MICROINVERTER(S): Enphase M215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10646	15041-10000-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	Pc for power and energy for replacement/upgrade of the mall distribution system, common area lighting, and receptacles. New HVAC, additional generator, replacement of outdate panels and meter centers. upgrade a couple of services and refeed existing tenants.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10647	17041-20001-08031	14720 W RINALDI ST	91340	7	213B149   249	2613017005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.28028	-118.45373	expedite.pv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10648	14041-20001-02594	16249 W ITASCA ST	91343	12	201B137   778	2677017008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.24525	-118.48646	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS$0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10649	16041-10000-01198	1028 W MIRAFLORES AVE	90731	15	021B197   382	7445020030	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	33.75297	-118.29964	PV1, Install 2.65 kW DC/3.00kW AC roof-mounted solar array, interconnect to an existing 3.0kWac pv system. Total system size with existing system is 6.00kWac. (1) Inverter. : SOLAREDGE SE3000A-US-ZB-U. (10) Modules: KYOCERA  KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10650	14041-20002-21838	5420 N YOLANDA AVE	91356	3	174B121   813	2161026004	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			07/22/2015 12:00:00 AM			PC Approved	07/22/2015 12:00:00 AM	ADDRESS	34.16939	-118.54034	07/22/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 4. Changes include the relocation per DWP request of switchboards 'MSA', 'MB1', and 'HS' to reflect field changes.*****Previous Work Description*****2.2.2015 - Plan check for modifications to approved set. Relocate meter bank MB2, adjust feeder sizes to compensate for different voltage drops/fault currents to unit panels. Delta 1A changes.57  units Condo over Type I-A Garage.Fire alarm variance filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10651	15041-10000-05124	12655 W JEFFERSON BLVD	90066	11	102B161    13	4211005019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	33.97916	-118.41469	Plan check for power and energy. Renovation of existing office building. Applicant approved to bring in T24 sheets and more panel schedules another day. Verify fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10652	11041-10000-14109	624 S GRAND AVE	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Expired	04/03/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	NEW DC PLANTS (AC TO DC CONVERTORS)  AND PANELS FOR TELCOM POWER EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10653	15041-10000-27322	10204 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Issued	08/20/2015 12:00:00 AM	ADDRESS	34.25583	-118.57964	PC FOR NEW FIRE ALARM SYSTEM FOR COMMERCIAL 1-STORY BUILDING (BANFIELD PET HOSPITAL) . NON-SPINKLER FOR  1ST FLOOR. TOTAL AREA IS  3454 SQ FT. SCOPE INCLUDES (1) FIRE ALARM PANEL AND (37) FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10654	19041-10000-33702	5620 W DE LONGPRE AVE	90028	13	147A193   198	5544030052	R4-2	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM	07/07/2021 12:00:00 AM		Permit Finaled	09/12/2023 12:00:00 AM	ADDRESS	34.09673	-118.31166	Full PC for power and energy for a scope of work is a new apartment building. Scope includes a new 2500A service, that feeds various new panels, new elvators and power transformers. Total affected area is 124,883Sq. Ft. Note: not considered highrise per bulding, highest occupied level is less than 75ft above fire department access. B#: 19010-10000-01942	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10655	16041-20001-26751	10534 W SANTA MONICA BLVD 1-9	90025	5	132B157  1078	4317004016	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM			PC Approved	10/20/2017 12:00:00 AM	ADDRESS	34.05456	-118.42769	10.20.2017 - Plan check for changes to approved set. Adding 30HP fire pump and garage supply fan (GSF-1). Adding fire dampers. Service equipment boards MS1 and MS3 are fed through bussing instead of feeders. Changes clouded delta C.======plancheck for power and energy.  new 37 unit apartment 5 story over 3 subterranean parking. [ FEES ARE BASED ON PRECUT CHECK, PLANCHECKER TO RECALCULATE].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10656	16041-20001-41228	4169 N GREENBUSH AVE	91423	4	165B157   928	2373007015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM			PC Approved	12/03/2016 12:00:00 AM	ADDRESS	34.14615	-118.42621	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.915 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10657	12041-20000-06505	7150 N TAMPA AVE Shulman-Bldg.	91335	3	183B117    99	2129001009	R1-1, RD2-1	South Valley	Reseda - West Van Nuys	Reseda		1325.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.20068	-118.55332	Fire Alarm t.i. & upgrade	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10658	17041-10000-10265	5050 W PICO BLVD	90019	10	129B181  1003	5070017002	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Info Complete	04/28/2017 12:00:00 AM	ADDRESS	34.04771	-118.34793	Methane gas detection system of a METHANE MITIGATION SYSTE LEVEL IV, commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10659	16041-20001-15161	4700 W SUNSET BLVD	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.09788	-118.29194	Change to carport lighting fixture type and quantity.  (((PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORT.  28355 SQFT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10660	15041-20001-24195	4914 N WAWONA ST	90041	14	162A219   224	5683029022	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.1378	-118.22472	04/05/2016 Changes to an existing PV1 roof-mounted PV system. Inverter has remained the same, but string length of 1 of 2 strings has increased by 4 modules. Original PV system has been finaled under the master application.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10661	10041-10000-23433	11811 W KIOWA AVE 1-9	90049	11	129B145   548	4265015035	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			11/23/2010 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.04961	-118.46467	NEW 9-UNITS APARTMENT BLDG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10662	13041-10000-20011	18555 W DEVONSHIRE ST	91326	12	204B125    99	2728028016	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	PIN	34.25817975	-118.53780185	FIRE ALARM SYSTEM IN AN COMMERCIAL LOCATION ; ADDITION OF A PANEL AND DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10663	14041-10000-17364	12518 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	33.97836	-118.41209	PC FOR METHANE MITIGATION. NEW Type VA  6-unit  4-story  APARTMENT BUILDING with attached parking. 1 PANEL AND 27  DEVICES.BUILDING APP #:14010-10000-01300	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10664	11041-10000-09774	7288 W SUNSET BLVD 1-14	90046	4	147B181   666	5548019056	[Q]C2-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Approved	07/15/2011 12:00:00 AM	ADDRESS	34.09775	-118.34914	TI TO A RETAIL SPACE.  COMBINING  SUITES#1D, 1E AND 1F INTO A SINGLE PETCO STORE.  REQUEST BY CUSTOMER FOR T-24 WITH EMERGENCY, OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10665	13041-10000-19738	2682 W MOSS AVE	90065	1	150B213   100	5457016007	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Apartment			07/25/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.11111	-118.23814	PV1 1.47KW 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: POWERONE PVI-3.0-OUTD-US ] [( 6) MOD: TRINA {TSM-245PC05.18}]  1 of 3 13041 10000 19738 (2682 moss ave)for reference:2 of 3 13041 10000 19746 (2682 1/2 moss ave)3 of 3 13041 10000 19749 (2684 moss ave)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10666	17041-20000-29328	22111 W CAJUN CT	91303	3	183B101   858	2024012***	(T)(Q)RD2-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.2001	-118.60859	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (20) modules. PV system is interconnecting with a center-fed panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10667	17041-20000-20001	6358 W YUCCA ST	90028	13	150A187   353	5546005024	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Apartment			06/14/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.10378	-118.3287	service upgrade 800amps to an existing apartment building. New 29 unit panels. plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10668	14041-10000-17634	1832 N JOHNSTON ST	90031	1	135A223    55	5210024022	M1-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.06534	-118.21005	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 2476 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10669	13041-20000-27068	8051 W BEVERLY BLVD	90048	5	138B177   392	5514007045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			09/30/2013 12:00:00 AM			PC Approved	10/04/2013 12:00:00 AM	ADDRESS	34.07625	-118.36496	Change to lighting and receptacles for a juice bar.  Load is less than 400 amps and occupancy load is less than 99 people.  PLAN CHECK ONLY for Energy with Emergency Lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10670	10041-10000-18456	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	07/19/2011 12:00:00 AM	PIN	33.92817449	-118.43220714	Fire alarm system for two story environmental learning center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10671	11041-20000-15821	606 S OLIVE ST #1900 &-#1970	90014	14	129A209   118	5144003037	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	ADDRESS	34.04779	-118.2542	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT OF OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10672	19041-10000-40726	6725 W SUNSET BLVD 280	90028	13	147A185    46	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.09814	-118.33717	TENANT IMPROVEMENT WORK IN AN EXISTING OFFICE AREA IN SUITE# 280 IN A LOW RISE BULDING ON 2,454 SFT OF THE TOTAL FLOOR AREA.  T-24 ENERGY ONLY.BUILDING PERMIT: 19016-70000-28775	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10673	17041-10000-05948	11369 N COMETA AVE	91331	7	213B165   637	2532023020	RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.27704	-118.40246	Plan check for PV roof mounted system. System size: 3.6kW with 19 modules and 1 inverter(3.6)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10674	13041-10000-04838	2960 W BROADWAY	90041	14	165A217    42	5680027020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM			Reviewed by Supervisor	04/18/2013 12:00:00 AM	ADDRESS	34.14564	-118.22857	Power and Enegry plan check. Service and panel upgrades with all new branch circuits for GAS STATION with convience store and car wash. Service upgrade from 400A to 1200A. 5 New panels. 23513 sqrft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10675	17041-20000-44865	23002 W SYLVAN ST	91367	3	177B097   149	2039010028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	PIN	34.1842535	-118.62796555	PV1.  Install 24.08 kW roof mounted grid tied PV system.  (72) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10676	17041-10000-13826	1816 W 6TH ST	90057	1	133-5A205 350	5142008014	C2-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.0581	-118.27219	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  25200 SQ FT. INDOOR/OUTDOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10677	15041-10000-08581	10317 N SILVERTON AVE	91042	7	204B201   439	2565005037	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.25648	-118.2841	PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(24) MODULES: KYOCERA KU2556XCA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10678	11041-20000-24208	1230 S MENLO AVE 1-60	90006	1	129B197   936	5076019019	R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			11/10/2011 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.04815	-118.29051	New fire alarm system for apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10679	14041-10001-09073	6128 S LA CIENEGA BLVD	90056	11	105B173    97	4001005016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	33.98267	-118.37012	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. {{{PV1, Install 5 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE3800A-US-ZB-U.(20) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10680	19041-20001-35956	640 N LAS LOMAS AVE	90272	11	129B121   819	4414013009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM			PC Approved	11/08/2019 12:00:00 AM	ADDRESS	34.04692	-118.53922	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED DELTA 3 ONLY, REMOVAL OF PANEL FROM SINGLE LINE, CHANGE TO MAIN BREAKER SIZE, AND RELOCATION OF GATEWAY ON SITE PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10681	18041-20000-39679	5990 N SEPULVEDA BLVD #310	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.17911	-118.46588	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 5,485 sq. ft.Note: Building application has been generated under 18016-30000-33489	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10682	11041-10000-25713	18510 W VICTORY BLVD	91335	3	180B125   658	2127012009	C4-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	04/24/2013 12:00:00 AM	ADDRESS	34.18638	-118.53642	Brand new McDonalds with new 1000A service and seven new subpanels, with new equipment and circuits.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10683	13041-10000-30447	578 S LORNA LANE	90049	11	132B145   226	4401011010	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.05701	-118.46992	"PV1. ROOFMOUNTED SOLAR ARRAY. MICROINVERTER NON STANDARD PLAN. SYSTEM SIZE: 6KW DC.  1 STORY HOUSE.(24) 250 W PV MODULES(24) 215 W ENPHASE MICROINVERTER.NOTE: AS OF 12/5/13, APPLICANT RETURNED TO RE-SUBMIT DRAWINGS WITH CHANGES ON THE ROOF LAYOUT( REMOVAL OF 2 MODULES PER LAFD REQUEST) & GOT APPROVAL FROM LAFD ON THE NEW PLAN. DUE TO THE CHANGE, STATUS WAS UPDATED FROM ""PLANS ON HOLD"" TO ""NO PROGRESS"" UNDER SUPERVISOR'S SUPERVISION.APPROVAL ACQUIRED FROM BUILDING UNDER 13016-10000-24986."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10684	14041-20000-16970	130 S ALVARADO ST	90057	13	135A205    60	5154006012	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.06574	-118.27071	Tittle 24 plan check only on 2rd floor with 10,972 SQ feet including unconditional area from a 2 stories commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10685	14041-20000-18519	1814 N DOHENY DR	90069	4	150B169  1254	5561008015	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.10484	-118.38808	New s.f.d. with basement and attached subterranean garage. pc for power. new 600A service. energy in accordance to 2008 standards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10686	17041-20000-18466	711 W 27TH ST	90007	9	121-5A203  19	5123017007	P-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Closed	09/18/2018 12:00:00 AM	ADDRESS	34.02836	-118.27921	PLANCHECK FOR POWER ONLY. INSTALLING 600 AMP SWITCHBOARD TO FEED TENANT THRU-WALL TYPE A/C UNITS.Note: Permit for the circuits was pulled as an express permit under 17041-10000-14660. This permit will cover the remaining equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10687	16041-10004-45090	1301 W 7TH ST	90017	1	130-5A205 108	5143013022	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.05249	-118.26766	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 30. CHANGES INCLUDE ADDITION OF 9 EXHAUST FANS ADDED TO PANEL SBHP. GARAGE FAN LOAD MOVED FROM PANEL HPC TO  PANEL HPB.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10688	11041-10000-14639	10145-10155 N RESEDA BLVD	91324	12	204B125   215	2729011004	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Issued	09/14/2011 12:00:00 AM	ADDRESS	34.25527	-118.53648	CONSOLIDATE SERVICES TO ONE 2500A 120/208 3PH 4W TO SUPPLY 5 EXISTING TENANT SPACES AND HOUSE METER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10689	05041-20002-08699	752 S MAIN ST 2ND FLOOR	90014	14	127-5A211 211	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.04283	-118.2527	PLAN CHECK ONLY. PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY LIGHTING) ON 2ND FLOOR CORRIDOR AND COMMON AREA RESTROOM. RESIDENTIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10690	17041-20000-44287	19351 W HATTERAS ST	91356	3	174B117    78	2153034031	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Issued	12/08/2017 12:00:00 AM	ADDRESS	34.17594	-118.55521	PV1.  Install 7.67 kW roof mounted grid tied PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10691	17041-10004-37680	5455 W 111TH ST	90045	11	087B173    10	4129036910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	33.93635	-118.37364	Change to approved set by updating all the different lighting  symbol under (1) type lighting fixture on floor plan	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10692	19041-10000-38943	21255 W BURBANK BLVD SUITE 200	91367	3	174B105    87	2149019018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM			Not Ready to Issue	09/26/2019 12:00:00 AM	ADDRESS	34.17432	-118.59446	THIS IS A PLAN CHECK ONLY FOR A TI TO AN EXISTING FIRE ALARM SYSTEM. SCOPE OF WORK IS ADDING DEVICES AND BATTERIES TO EXISITNG FIRE ALARM SYSTEM SPANNING THREE FLOORS. THIS IS THE SECOND FLOOR PORTION CONSISTING OF 98 DEVICES, AND TWO BATTERY. NOTE ALL FLOORS HAVE BEEN SEPARATED INTO THREE APPLICATIONS, ALL HAVE BEEN APPROVED BY FIRE. THE PERMIT FOR THE SECOND FLOOR HAS BEEN PULLED UNDER 19041-10000-31975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10693	18041-20003-19238	6160 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM	ADDRESS	34.18234	-118.39628	08-09-2019 Changes to an approved set of plan Builidng A, B, BA, changes include revise grounding detail from transformer to building distribution, loop distribution overcurrent protection ratings to address coordination. All changes has been clouded as delta 3. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10694	17041-10000-05188	13160 W MINDANAO WAY	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	33.98501	-118.43726	FULL PLAN CHECK TO EXISTING OFFICE BUILDING. INSTALLING 2 NEW FEEDERS AS REFLECTED ON SINGLE LINE. NEW POWER AND LIGHTING. AREA IS 28,488	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10695	19041-10000-30947	5966 N TOPEKA DR	91356	3	177B121   813	2156018044	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.1789	-118.54601	NEW ROOF MOUNTED 15.4KW PV SYSTEM WITH 49 PV PANELS AND OPTIMIZER AND ONE CENTERAL INVERTER ON A SINGLE FAMILY HOME.Permit fee is zero due to assembly bill 3434	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10696	16041-10000-44925	1149 S BROADWAY	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.03859	-118.26015	OFFICE TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10697	13041-10000-06603	5080 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2197.00, 2360.00, 2362.02	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	34.02028	-118.35491	FIRE ALARM SYSTEM FOR GROCERY STORE. TOTAL OF 1 PANEL. AND 65 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10698	17041-20000-00394	7500 N LANKERSHIM BLVD	91605	2	186B169   461	2316013003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.20684	-118.38758	Service upgrade 600 amps to an existing gym.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10699	13041-10001-34104	1935 E 7TH ST	90021	14	124-5A217 213	5164021009	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.03477	-118.2329	CHANGES TO APPROVED SET. SUPPLEMENTAL PLANCHECK FOR T24 CHANGES AND SUPPLEMENTAL PERMIT FOR ADDITION FOR 75KVA TRANSFORMER, 225AMP PANEL AND ADDITIONAL CKTS.13041-10000-34104 :PLAN CHECK FOR T24 ENERGY ONLY FOR WAREHOUSE AND OFFICE ( 15635 + 828 SQFT), EMERGENCY LIGHTING.  BUILDING PC# 13014-10000-01022. NEW 2ND FLOOR OFFICE (930 SF) & WAREHOUSE (5447SF) ADDITION  WITHIN  (E) 2-STORY WAREHOUSE .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10700	10041-10001-17214	5933 W BOWCROFT ST	90016	10	117B173   121	4204008045	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM			PC Approved	11/23/2011 12:00:00 AM	ADDRESS	34.01927	-118.37733	Plan check for new installation of 77KW Photovoltaic System connected on the line side.THis plan check was to verify the load and not the PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10701	16041-20000-03236	4109 W CLAYTON AVE	90027	4	148-5A201 221	5430003022	R1-1	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Issued	02/11/2016 12:00:00 AM	ADDRESS	34.1001	-118.28075	Plan check for a backup battery bank  5kW  for an existing PV system on a Single Family Dwelling. PV system is utility-interactive.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10702	15041-10000-01451	7337 W PACIFIC VIEW DR	90068	4	156B177   611	2428016005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			Reviewed by Supervisor	01/29/2015 12:00:00 AM	ADDRESS	34.12144	-118.35321	13.77kW PV system. 2 Inverters, 1 4200 W, 1 6000W. 54 modules. 2 combiner boxes	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10703	17041-20000-04879	910 S BROADWAY	90015	14	127-5A209 260	5139002017	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.04197	-118.25618	New outdoor facade lighting for (E) commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10704	17041-10001-14304	8742 N FARRALONE AVE	91304	12	195B101   241	2010007004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.22984	-118.61063	PER INSPECTION - PC FOR A ROOF MONTED PV SYSTEM 3.8KWAC WITH 12 AC MODULESPERMIT PULLED UNDER MASTER APP. Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10705	18041-20000-23360	21933 W VENTURA BLVD #B	91364	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.16868	-118.60493	Plan check for Title 24 only in existing space, T.I. office space. Total area: 1215 sq ft. B#18016-20000-20007	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10706	19041-20000-23046	20511 W DUMONT ST pv1	91364	3	169-5A111  15	2166020001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Issued	06/17/2019 12:00:00 AM	ADDRESS	34.16063	-118.58076	pv1install roofmounted pv system sized 7.6KW AC interconnected with msp.(1) tesla Ess rated 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10707	13041-20000-29392	13751 W HUBBARD ST	91342	7	222B153   124	2509014093	QR3-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.30578	-118.43247	PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 10.6 KW AC USING 36 MODULES. USING 2 CENTRAL TRANSFORMERED INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10708	14041-10000-08009	13950 W GARBER ST	91331	6	198B153    29	2642013019	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.24334	-118.43699	PV1 ROOF MOUNTED MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 4.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10709	17041-10000-43253	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.13855	-118.36112	Plan check for power only for Medium Voltage new transformer 4160/480V for new chillers and 12 new variable frequency drives. Provide power to new chillers and refrigerant monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10710	18041-20000-46801	7065 W SUNSET BLVD	90028	13	147B181   582	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM			PC Info Complete	02/14/2019 12:00:00 AM	ADDRESS	34.09813	-118.34362	TI TO AN EXISTING COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR INDOOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10711	16041-30001-12125	21935 S HARVARD BLVD	90501	15	048B193   276	7346010036	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	33.8284	-118.30671	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size =  5.59 kWac.  Microinverter system with two branch circuits and 125 A solar only load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10712	18041-10000-08937	18705 W VENTURA BLVD	91356	3	174B121   514	2160002005	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Issued	04/03/2018 12:00:00 AM	ADDRESS	34.17095	-118.54095	PC for T24 only for lighting alterations for Chase bank. Replacing existing ligths with new LED's. Total area (indoor and outdoor) is 33107sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10713	15041-10001-33233	7652 N TUJUNGA AVE	91352	6	186B173    69	2315010040	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	PIN	34.20995941	-118.37872208	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PVI, INSTALL NEW 6.867 KW DC ROORF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(21) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTER: ABB PVI-3.8-OUTD-S-US-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10714	16041-20002-23916	715 S KINGSLEY DR	90005	10	132B193   367	5093021024	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.05927	-118.30321	changes to an approved set of plans.  changes include downsize (1) inverter to 8kw and reconnect to msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10715	17041-20000-41720	814 N SAN FERNANDO ROAD	90065	1	144A219    36	5453006048	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Issued	01/05/2018 12:00:00 AM	ADDRESS	34.09066	-118.22723	Note: $0.00 permit fee due to CA Senate Bill 1222PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 126.75 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10716	19041-20000-41063	11881 W TERRA VISTA WAY #117	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10717	11041-10002-08145	421 N HENRY FORD AVE	90744	15	027B213     1	7440003***	M3, M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			Corrections Issued	04/26/2012 12:00:00 AM	ADDRESS	33.77533	-118.24134	approved plans were permitted up to the secondary of EACH MV transformer which is to supply a oil weell motor; this plan check is for 6 ea MV MOTORS INSTALLATION:  2 EA 45HP pump/motors on swrk 1SW1; 1 EA 119HP MOTOR ON SWRK 2SW1 ; 1 EA 100HP MOTOR ON SWRK 2SW3 AND 1EA 70HP AND 1 EA 90HP MOTORS ON SWRK 2SW4.Installing 6 new feeders, X-formers, VFD & pumps for an oil wells. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10718	19041-10000-41117	555 W 5TH ST 17TH FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.05016	-118.25369	Energy plan check for an office T.I. located in HIGH RISE building. Scope includes new lighting and equipment with a total lighting area or 900 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10719	15041-10000-15644	11478 W HART ST	91605	2	183B169   287	2320004005	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.19746	-118.38171	Retrofit of existing lights to LED fixtures.  Title 24 Part 6 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10720	15041-10000-16840	261 S FIGUEROA ST STE 120	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Closed	08/03/2018 12:00:00 AM	ADDRESS	34.05546	-118.25446	Energy plan check for an office T.I  Scope includes new lighting and receptacle.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10721	10041-10000-22507	22800 W VANOWEN ST	91307	3	180B097    44	2038040029	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.19353	-118.62404	Ti in an existing restaurant. EPC is for T24 and Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10722	18041-10000-45669	8800 S SEPULVEDA BLVD	90045	11	096B165   956	4123001001	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.95697	-118.39597	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10723	13041-20000-34776	14901 W OXNARD ST	91411	6	177A149   108	2242027021	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.17954	-118.45778	T24 FOR EXISTING RETAIL SPACE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 200A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10724	18041-20000-03963	20544 W DEFOREST ST	91364	3	169-5A111  39	2166023016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.16008	-118.58091	PV1.  INSTALLATION OF 10.8KW PV SYSTEM ON A SINGLE FAMILY HOME USING 34 AC MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10725	13041-20001-35038	10158 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.25464	-118.57964	PC FOR T24 ENERGY ONLY. RESTAURANT. LOW ADDITIONAL LOAD. T24 ONLY(((restamp new set of plans. new set to take over original set. plan check was for T24 energy only. no change in lighting load. this is restamp)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10726	13041-20000-26891	901 S ABBOT KINNEY BLVD	90291	11	109-5A143 374	4286012008	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	33.9927	-118.47312	T24 FOR EXISTING TWO STORY OFFICE BUILDING. 3726 SQRFT. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10727	13041-20000-27292	25965 S NORMANDIE AVE 2nd floor-3rd floor	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	Replace/retrofit lighting on the 2nd and 3rd floors.  No new loads or circuits.  Kaiser Medical Building.  PLAN CHECK ONLY for Energy with Emergency lighting. {{INSPECTOR TO VERIFY THAT THERE IS NO WORK IN PATIENT CARE AREAS}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10728	13041-10000-20250	9519 N RINCON AVE	91331	7	198B161    86	2626014016	RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.24212	-118.41323	PV1 8KW 240V XFMR INV. 1STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 33) MOD: TRINA {TSM-250PA05.08}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10729	19041-10000-33517	17819 W LOS ALIMOS ST	91344	12	207B129   197	2712021012	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			Reviewed by Supervisor	09/04/2019 12:00:00 AM	ADDRESS	34.2663	-118.52222	PV1 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND DC BATTERY COUPLED SYSTEM. (20) MODULES, (20) OPTIMIZERS, (1) 7.6 INVERTER, (1) 5KW lg CHEM BATTERY. TOTAL SYSTEM SIZE IS 7.6 KWAC / 6.583KWDC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10730	17041-10000-39185	312 S ALAMEDA ST	90013	14	127-5A215  66	5163010009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.04494	-118.23784	PC for power and energy for first time restuarant tenant. Installing three new panels, new equipment, circuits, lights and receptacles. Total area is 3520sqft. Total area is	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10731	19041-20000-09316	12431 W ROCHESTER AVE	90025	11	126B145   888	4267034020	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Apartment			03/14/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.03904	-118.46767	Fire alarm system for 5-story 50-unit apartment building.  (123) devices with FACP and (4) power expanders.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10732	19041-20001-15177	6561 W 84TH PL	90045	11	096B165   170	4108013003	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM			PC Approved	05/13/2019 12:00:00 AM	ADDRESS	33.9621	-118.40376	05/13/2019 Changes to an approved set of plans. Changes have been made to reflect field conditions. *****Original Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10733	18041-10000-45205	7021 W HOLLYWOOD BLVD	90028	13	147B181   115	5548003020	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	34.1017	-118.34273	POWER AND ENERGY PLAN CHECK  FOR POWER AND ENERGY FOR  REMODELING  IN AN EXISTING COMMERCIAL BLDG. SCOPE INCLUDES COMBINNING TWO TENENT FLOORS INTO ONE (CORE AND SHELL) WITH NEW STAIR,  ESCALATOR,  ELEVATOR, NEW DISTRIBUITION SECTION AT  1000A, PANEL, EQUIPMENT, RECEPTACLES. NEW LIGHTING FOR 4 ELEVATOR LOBBIES. TOTAL AFFECTED AREA IS 8331 SQ.FT INDOOR AND OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10734	17041-10000-20209	14040 W FOOTHILL BLVD	91342	7	225B153   250	2504019049	R3-1-CPIO	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.31435	-118.43968	PC FOR PV SYSTEM CONNTECTED TO EXISTING MAIN PANEL. THIS IS COMMERCIAL PV. THIS SYSTEM USES 5 INVERTER, TOTAL RATED34.2KW AC. THIS SYSTEM NET METERS METER # FM19-62711. THIS IS SYSTEM 3/3 ON SAME ROOF. SYSTEM USES POWER OPTIMIZERS. *** NOTE: PERMIT FEES DUE IS $0 DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10735	14041-20000-26084	325 N GOODHOPE AVE	90732	15	018B189    71	7559009002	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM			Corrections Issued	09/22/2014 12:00:00 AM	ADDRESS	33.74654	-118.31626	PV1 SFD. THIS IS AN ADDITION TO EXISTING PV STSTEM. ADDITION CONSIST OF NEW 4.2KW AC RATED SYSTEM. TRANSFORMERLESS INVERTER. NONTANDARD PLAN. NEW SOLAR COMBINER. 16 NEW PV MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10736	16041-10000-00538	1256 W 7TH ST roof	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	03/24/2023 12:00:00 AM	ADDRESS	34.05216	-118.26774	replacing two chillers and adding a panelboard on the roof of a hotelone chiller is supplied from a 120/240v 3ph 4w distbd and other chiller supplied from 120/208v 3ph 4w distbd	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10737	18041-20000-00131	12001 MIRABEL WAY	91326	12	216B109   172	2701081021	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Issued	01/02/2018 12:00:00 AM	PIN	34.29061503	-118.58245755	pv1install roof mounted pv system sized 4.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10738	16041-30000-29142	8532 W CASHIO ST	90035	5	129B173   569	4303032005	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			08/16/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.05076	-118.37735	Plan check for new appartment building 7 units. Total area: 12,992 sq ft. Title 24 shall based on 2013Bldg permit # 14010-10000-03557	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10739	14041-20001-05381	10131 N GENESTA AVE	91325	12	204B133   380	2694018023	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.25492	-118.50475	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.6 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 35 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10740	14041-20001-02596	12811 N FENTON AVE	91342	7	222B161   436	2525024032	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.30217	-118.413	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10741	16041-20000-04955	5757 W WILSHIRE BLVD #106	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check Title 24 only for existing space T.I. Starbucks Coffee. Total area: 1,733 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10742	13041-20000-15770	4195 E YORK BLVD	90065	14	156A219    11	5473015002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.12375	-118.22648	PV system for an existing single family dwelling.  Enphase Microinverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10743	18041-10000-12161	11601 W WILSHIRE BLVD STE# 355	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	PLAN CHECK FOR FOR TITLE 24 ONLY FOR TENANT IMPROVEMENT WORK ON APPROX. 3,298 SF OF THE TOTAL FLOOR AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10744	14041-20000-08319	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLANCHECK FOR T24 ENERGY PER INSPECTORS REQUEST. TENANT IMPROVEMENT TO MACYS MENS SECTION. PERMIT PREVIOUSLY PULLED UNDER 13041-90000-14765.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10745	16041-20002-23165	210 N LADERA DR	90210	5	141B157    93	4358006046	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Issued	10/04/2017 12:00:00 AM	ADDRESS	34.08184	-118.4235	[[7/19/17 CHANGES TO APPROVED SET. ADDITION OF NEW PANELS E,G,HT, AND LI, LF, NEW STANDBY GENERATOR, NEW GARAGE BLDG, AND NEW LIGHTING CONTROL SYSTEM, NEW LANDSCAPE LIGHTING]]][[5/24/17 CHANGES TO APPROVED SET. SERVICE UPGRADE TO 3 PHASE 800 AMPS . ADDITIONAL LOADS WERE ADDED]]]Plan check for SFD(Single Family Residence) power only replace existing 600A main switch gear with a new switch gears(2) at 600A with associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10746	11041-10000-25926	8250 N TUJUNGA AVE	91352	6	192B173   509	2314001001	M1-1, M2-1-G, M3-1-G, [T]P-1, [T]P-1-G, [T][Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Info Complete	02/27/2012 12:00:00 AM	ADDRESS	34.22023	-118.37892	Upgrade to 800A service for a recycling center for outdoor equipment.  All panels and equipment will be located outdoors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10747	18041-20000-36001	15350 W SHERMAN WAY	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Info Complete	09/20/2018 12:00:00 AM	ADDRESS	34.20099	-118.46808	ti to an exisrting commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10748	14041-20000-04174	5834 E EATON ST	90042	14	157-5A229 318	5485018006	RE11-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.12474	-118.19078	Roof mounted PV system with 3.75 KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10749	14041-20000-02706	22032 W GRESHAM ST	91304	12	195B101   232	2010008001	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.23006	-118.60702	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 9.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10750	16041-10002-08550	200 N SPRING ST 19TH FL &-21ST FL	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.05405	-118.24317	Changes to approved set.  Changes to lighting layout on 21st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10751	19041-10000-38688	511 S UNION AVE	90017	1	133-5A205 331	5153004018	R4-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	34.05827	-118.26943	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10752	10041-20001-12214	13203-13249 N GLADSTONE AVE	91342	7	225B157   672	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Approved	02/11/2011 12:00:00 AM	ADDRESS	34.31052	-118.42831	revision to title 24 by inspector request	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10753	17041-20003-45534	13571 W VAUGHN ST	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.27758	-118.42846	09/07/2018 Changes to an approved set of plans. All changes have been clouded. Details have been provided for conduit expansion fitting spacing, wire bending junction box sizing calculations, and series rating information.*****Previous Work Description*****Revisions to approved set.  Approval for clouded portions of plan only.  Wiring detail changes.(((PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2217.53 KW.  PV system is a feed and tariff system. RESUBMITTAL TO EXPIRED PLANS 15041-20000-08646(5614)  LG395 395 WATT MODULES(30) SMA 24(23) SMA 23(18) SMA 1857BUILDING PERMIT # 15016-20000-20234)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10754	17041-10000-24510	18251 W NAPA ST	91325	12	195B125   964	2786003042	M1-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.22659	-118.53127	Plan check for Title 24 only in existing space, replace existing outdoor fixtures with LED fixture. Total area: 151,450 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10755	13041-20000-23809	2737 N BEVERLY GLEN BLVD	90077	5	156B149    66	4379005028	RE15-1-H-RPD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.1209	-118.44648	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6 KW AC USING 18 MODULES. 3 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10756	16041-10000-08337	207 S BROADWAY	90012	14	130-5A213  23	5149009022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.05231	-118.24703	CHANGE OF USE TO COCKTAIL/BAR. ASSEMBLY OCCUPANCY 122 OCCUPANTS. PC FOR POWER AND ENERGY. NEW POWER AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10757	13041-10001-29530	11770 W STONEHENGE LANE	90049	5	150B141    60	4377046023	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	PIN	34.11023837	-118.47697835	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10758	18041-10000-32672	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	Revision to approved plan, scope includes redefined the area of work, remove lightings and receptacles, revise T24 calculation. All other informaion are remain the same.  This is supplemental plan check only, permit is covered under master plan #18041-20000-11914. <<Plan check for Title 24 only in new sprung conopy to house baggage handling equipment(Carousel). Total area: 3,289 sq ft>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10759	18041-20001-44018	21902 W DEVONSHIRE ST	91311	12	204B101   187	2747016042	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.257	-118.60514	Revision to approved plans.  Miscellaneous changes to power and lighting plans, SLD, and panel schedules.  (((Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a change of use from bank to dental office. Work includes 400A Service a total lighing area of 3,432 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10760	13041-10000-16351	11941 N SIERRA LANE	91326	12	216B121   238	2872004019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.28953	-118.55119	New roof mounted PV system with 10.29 KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10761	18041-30001-35559	350 S GRAND AVE GROUND-FLR.	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	01/15/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.*****Original Scope of Work*****PLAN CHECK FOR T24 ONLY,  TENANT IMPROVEMENT WORK ON +/- 7525 SQFT. OF THE EXISTING 1ST FLOOR SUITE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10762	18041-10000-14230	2115 W BEVERLY BLVD	90057	13	136-5A205 307	5157020011	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	12/19/2023 12:00:00 AM	ADDRESS	34.0671	-118.27084	SERVICE UPGRADE TO 800 AMP. RELOCATE AND RECONNECT EXITING GENERATOR, TRANSFER SWITCH AND RECONNECT TO EXISTING PANELS AND LOADS.IN METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10763	15041-20000-13190	13262 W VAUGHN ST	91331	7	213B157   268	2524024005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	PIN	34.28175739	-118.42187903	Plan check for PV  roof mouned system solar array 3.8kWac with 1 inverter(SOLAREDGE SE3800A-US) and 19 modules (TROMA TS-260 PAO5A)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10764	19041-20000-07530	4185 W DON LUIS DR	90008	8	114B181   702	5026010003	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.00569	-118.34373	PV1.  Install 6.50 kW roof mounted grid tied PV system.  (20) modules with 6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10765	07041-10002-30616	5031 N FAIR AVE	91601	2	171B173  1095	2353012016	R4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			08/20/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	34.1617	-118.37478	REVISIONS TO PERMITTED SET OF PLANS-FEEDERS TO APARTMENT PANELBOARDS  CHANGED TO ALUMINUMNew 308 units apartment building.  Fire alarm variance has been filed.  Fees for Apt smoke detectors TBD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10766	10041-20000-05831	6748 W HILLPARK DR	90068	4	154-5A185  11	5549004***	RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.1185	-118.34073	installing emergency light and exist sign in apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10767	18041-10000-25809	10250 W SANTA MONICA BLVD #2530	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Issued	09/11/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC RETAIL T.I . FOR T-24 ENRGY ONLY. SCOPE INCLUDES NEW 24FT OF TRACK IN EXISTING SALES FLOOR.  REVISION TO CURRENT LIMITER. TOTAL AFFECTED AREA 2128 SQ.FT. ORIGINAL T.I WORK UNDER 17041-10000-38616 (FINALED).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10768	15041-20000-04402	3847 S REDONDO BLVD	90008	10	117B177   170	5029005033	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.01687	-118.35929	PV1MICROINVERTER STANDARD PLAN SYSTEM SIZE 3.8KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10769	14041-20011-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			09/12/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	33.95605	-118.38499	09-10-2018  Changes to an approved set of plan.  Changes include revised Emergency lights to be connected to EM lighting inverter (4 kW) and add HVAC to IDF room, add dedicated circuit control damper in each unit.  All changes has been clouded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10770	19041-10000-19714	5975 N SHOUP AVE	91367	3	177B101   160	2040041008	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Issued	10/25/2019 12:00:00 AM	ADDRESS	34.17892	-118.61491	FULL PLAN CHECK FOR SCHOOL TENANT IMPROVEMENT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 137,461 SQ.FTBUILDING # 7 AND SITE LIGHTING ON THIS PERMIT3 - 5B#19016-10000-15467	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10771	17041-20000-40614	361 N GENESEE AVE 1-4	90036	5	138B177   116	5527039032	RD1.5-1-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Apartment			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.07783	-118.35871	Fire alarm system for 3-story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10772	15041-10000-11874	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	PIN	33.92817449	-118.43220714	ADDING 5 NEW FIXTURES TO AN OUTDOOR HYPERION WASTE LAND. SPACE. TI 24, PC FOR ENERGY ONLY. TOTAL SQ. FT. 1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10773	18041-10000-47829	11247 W TUXFORD ST	91352	6	195B173   255	2408036040	M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Issued	12/18/2018 12:00:00 AM	ADDRESS	34.23086	-118.37673	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10774	14041-20002-24308	13854 W MAGNOLIA BLVD	91423	4	171B153   466	2269006002	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.16466	-118.43527	Modification to approved set.  Change of feeder details from load center to MSP.  $0 plan check fee is due to Senate Bill SB-1222. (((PV1.  Install 14.0 kW roof-mounted, utility-interactive PV system.  Microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10775	11041-10000-13810	108 S ROBERTSON BLVD	90048	5	138B169   393	4334005003	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Closed	10/07/2011 12:00:00 AM	ADDRESS	34.07492	-118.3836	T.I.  First time tenant.  Retail space.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10776	13041-20000-12534	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	MASS RENOVATION OF JC PENNY. AFTER DEMO, NEW CONNECTED LOAD TO EXCEED 400A. PC FOR POWER AND ENERGY. APPLICANT WILL DROP OFF PANEL SCHEDULES. TOTAL AREA >30000 SQ FT. ENERGY PLAN CHECK USING 40,000 SQ FT TAILORED METHOD. ADDITIONAL PLAN CHECK HOURS HAVE BEEN ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10777	19041-20000-05151	590 S BURLINGAME AVE	90049	11	129B141     1	4264008001	A1-1XL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.04606	-118.48522	Conversion of portion of golf pro shop to golf practice area.  1,155 sq ft - plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10778	18041-10000-43339	5416 N FAIR AVE	91601	2	171B173  1415	2350013020	CM-1VL, PF-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Apartment			11/13/2018 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	34.16931	-118.37409	T-24 PLAN CHECK FOR TI REMODEL OF EXISTING CLUBHOUSE LOBBY AND EXISTING GYM. REPLACEMENT OF LIGHTS TO LED AND INSTALLING NEW LIGHTS. PLAN CHECK FOR LIGHTS AND OUTLETS ONLY. TOTAL SQFT 4537	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10779	18041-10001-33039	10990 W WILSHIRE BLVD #220	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.0577	-118.44711	PLAN CHECH FOR TITLE 24 ONLY FOR SUITE # 220 - TOTAL AFFECTED AREA = 2112 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10780	17041-20000-22664	15821 W VENTURA BLVD 2nd Floor-Corridor	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for energy only. TI to corridor on 2nd floor of high rise building. New lighting (incl. emergency).4,015sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10781	17041-20000-31314	4947 N CHIMINEAS AVE	91356	3	168B125   112	2181019008	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.15993	-118.52912	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (20) modules. Center-fed MSP, variance has been submitted.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10782	15041-10000-01484	450 S WESTERN AVE	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	(N) fire alarm installation in 3-story commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10783	14041-20000-13145	20226 W SEPTO ST	91311	12	201B113   112	2741017015	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.25077	-118.57424	Roof mounted PV system with Optimizers and tranformerless inverter.  System size is 7.4KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10784	16041-10000-43106	5166 N VINELAND AVE	91601	2	171B173  1380	2419001044	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.16464	-118.37008	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total area:11400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10785	19041-20000-44224	6252 W DELFINO ST	91042	7	201B205   285	2571002034	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	34.24921	-118.26724	PV1. INSTALL 12.285 KW DC PV SYSTEM WITH (39) MODULES/OPTIMIZERS , (1) INVERTER (SE11400) AND (2) TESLA STORAGE BATTERIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10786	14041-20000-14214	5222 N ETHEL AVE	91423	4	171B161  1218	2345018071	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	PIN	34.1654321	-118.41798238	Roof mounted PV system with Optimizers and tranformerless inverter.  PV system size 10KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10787	13041-10000-10785	10511 N ANDORA AVE	91311	12	207B101   219	2723007012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11, 1132.12	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.26133	-118.60951	INSTALLING PV SYSTEM TO SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 26.16KW. [INVERTER: SUN POWER SPR-11401F-1 UNI] [PV MODULE: SUN POWER SPR327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10788	12041-10000-07241	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	Replacing the exixsting boiler with new at the hyperion  plant. low voltage instrumentation not scope of this project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10789	11041-10000-25303	4300 N GRIFFIN AVE	90031	1	145-5A225 379	5303006001	[Q]C1-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM			PC Approved	11/28/2011 12:00:00 AM	ADDRESS	34.09207	-118.2038	T.I. to an existing grocery store.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10790	12041-10000-01379	10714 1/4 W RIVERSIDE DR	91602	4	165B177    99	2423005020	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	PIN	34.1518827	-118.36418703	T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE SPACE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10791	14041-20000-15326	5717 N COMANCHE AVE	91367	3	174B113   221	2151010023	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Expired	07/21/2016 12:00:00 AM	ADDRESS	34.17454	-118.57298	PV1Central Transformerless Inverter Standard PlanInstall roof-mounted solar array on SFD. System size: 5kW.(1) Power-One PVI-5000-OUTD-US-A transformerless inverter(24) REC Solar REC260PE pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10792	14041-20000-00507	8434 N GLASSPORT AVE	91304	3	192B105   363	2779012047	R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.2231	-118.59382	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 7.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10793	18041-20000-16812	725 S FIGUEROA ST 5th Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	Tenant improvement of (E) commercial highrise office space.  Plan check for energy - 19,451 sq ftBuilding permit filed under 18016-10000-08933.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10794	17041-10000-14064	4807 W ELMWOOD AVE	90004	4	138B193    29	5522020011	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	07/11/2021 12:00:00 AM	ADDRESS	34.07842	-118.31173	4 STORY 13 UNIT APARTMENT. 1 LEVEL GARAGE. PC FOR POWER AND ENERGYService rated at 1600A  120/208Vtotal affected area  17265 sq.ftB# 16010-10000-04103	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10795	13041-20000-20764	5450 W PICO BLVD	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.04862	-118.35714	RENOVATION OF TENANT SPACE. NEW CIRCUITS. EXISTING PANEL. PLAN CHECK FOR T24 ENERGY ONLY. TOTAL AREA 1357 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10796	16041-20000-14665	16626 W ARMINTA ST	91406	6	189B137    43	2205009036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.21474	-118.49572	PEMIT FEE $0.00 STATE SENATE BILL NO. 1222Install a roof-mounted solar array on a commercial building. Interconnect directly to LADWP = FEED-IN-TARIFF SYSTEM. System size: 100kW [(5) 20kW inverters]. Ungrounded system.(406) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10797	19041-10000-32187	4935 N CALVIN AVE	91356	3	168B117    75	2175010019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.15997	-118.56038	Plan check for a 10 kw AC / 10.68 KW DC PV1, roofmounted system. Scope includes (1) inverter, (35) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10798	18041-10000-45245	639 S BROADWAY 10TH FLOOR	90014	14	129A211   230	5144003040	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	07/28/2020 12:00:00 AM	ADDRESS	34.04587	-118.25309	PLAN CHECK FOR TITLE 24 ONLY FOR OFFICE TI COMMON AREA AND CORRIDORS OF 10TH FLOOR - TOTAL AFFECTED AREA = 8967 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10799	12041-10000-17921	13928 N MOUNTAIN VIEW PL	91342	7	228B161   871	2582039033	R1-1, [Q]RD6-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.32549	-118.41245	Plan check for PV. Roof mounted. Single family dwelling. 3.27kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10800	14041-10000-16954	2716 W SAN FERNANDO ROAD	90065	1	150B213   144	5457003019	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.1097	-118.24272	REMODELING OF A BAKERY IN A GROCERY STORE AND PRODUCE SECTION. THE SCOPE OF WORK INCLUDES LIGHTING, TITLE 24 ENERGY, AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10801	19041-10000-45872	2835 E WASHINGTON BLVD	90023	14	118-5A221  91	5169018006	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.01742	-118.21868	PC FOR ENERGY ONLY T-24 ONLY. SCOPE INCLUDES NEW OUTDOOR LIGHTING. TOTAL AFFECTED AREA IS 15325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10802	14041-20000-29580	720 E 246TH ST	90744	15	039B205   389	7404021026	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	PIN	33.80273088	-118.26147193	Roof mounted PV system with system size 6KW.Note: Zoning clearance approved under 14041-20000-29575	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10803	12041-20000-29988	3620 S VERMONT AVE Suite 345	90089	9	120B197   929	5039002030	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM			PC Approved	12/13/2012 12:00:00 AM	ADDRESS	34.02213	-118.29133	Plan check for energy and emergency lighting. USC. 1128sqft. Suite 345.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10804	12041-20000-07117	10780 W SANTA MONICA BLVD s.120	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	34.0504	-118.43387	office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10805	13041-10000-07712	5132 W JEFFERSON BLVD	90016	10	120B177   747	5047001002	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.02537	-118.35637	PERMIT IS FOR RELOCATED PANELS (4), BRANCH CIRCUITS (16), AND AC UNITS (8). PLAN CHECK FOR TITLE 24 IN AN EXISTING WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10806	17041-20000-13542	701 S BROADWAY B & C	90014	14	127-5A211  33	5144014038	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.04519	-118.25359	ti to an existing commercial building.  adding new lighting  new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10807	13041-10002-05748	380 WORLD WAY Space T45	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	REVISIONS TO PERMITTED SET OF PLANS: UPDATED POWER FOR RELOCATED UNDER-COUNTER REFRIGERATOR AND FREEZERS-SHEET E1.1:UPDATED PANEL SCHEDULES WITH NEW DISH WASHER MACHINEPROPOSED 709 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Petrossian).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10808	11041-20000-02391	15821 W VENTURA BLVD #230	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	02/07/2011 12:00:00 AM		Permit Finaled	03/10/2011 12:00:00 AM	ADDRESS	34.15584	-118.47812	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR SUITE #230	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10809	18041-10000-24709	5721 W 96TH ST	90045	11	093B169   127	4125021014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	33.94955	-118.38166	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10810	14041-20000-13183	21308 W CELTIC ST	91311	12	210B105   104	2706035003	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.27071	-118.5961	Roof mounted PV stystem with Enphase model M215-60-.  System size 5.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10811	12041-20000-20324	11760 W SAN VICENTE BLVD	90049	11	129B145    93	4265018017	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.05288	-118.46798	Plan check for energy only. ATM room (indoor), not in parking lot or outdoor. 72 sqft. Applicant was contractor; permit and plan check issued on the same day ===> plan check and permit share PCIS #.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10812	11041-10000-25583	11090 W OPHIR DR	90024	5	135B149   199	4363012002	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			12/05/2011 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.06817	-118.45452	PLAN CHECK POWER AND ENERGY FOR NEW FOUR STORY,  14 UNITS  APARTMENT BUILDING WITH ONE LEVEL OF SUBTERRANEAN BASEMENT PARKING. 1000A SERVICE SUPPLYING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10813	16041-20001-36717	13133 W BLOOMFIELD ST	91423	4	165B157   430	2375001068	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM			PC Approved	10/24/2016 12:00:00 AM	ADDRESS	34.14943	-118.41929	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (32) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10814	11041-10001-10894	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Closed	07/15/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	"REVISION TO APPROVED PLANS. PLAN CHECK FOR ADDITIONAL DEVICES SUCH AS TRANSPONDERS, RELAYS, AND SMOKE DECTECTORS INSTALLED TO NEW FIRE ALARM SYSTEM IN THE ""BRADLEY WEST CORE"" TBIT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10815	17010-10002-05068	545 S SAN PEDRO ST	90013	14	127-5A213 295	5148013006	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Closed	01/18/2019 12:00:00 AM	ADDRESS	34.04311	-118.24486	This Building Permit was issued in error & was replaced with Electrical Permit # 19041-10000-02231. Application Withdrawn.TI IN AN EXISTING EMERGENCY HOMELESS SHELTER. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10816	15041-20000-02007	1201 W 5TH ST SUITE 900	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.05429	-118.25967	"TI TO AN EXISTING OFFICE COMMERCIAL HIGH RISE BUILDING.  NEW LIGHTING NEW CONTROLS USING EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN SUITE 900.  TOTAL SQUARE FOOTAGE 5062.""COMPLY WITH DEPARTMENT ORDER effective date 01/26/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10817	10041-20000-21854	5900 W WILSHIRE BLVD 6th Floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/05/2010 12:00:00 AM		Permit Finaled	12/15/2010 12:00:00 AM	ADDRESS	34.06237	-118.35809	T.I. to a high rise building of 6th floor in elavator lobby and restroom.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10818	15041-10000-18090	6601 S CENTER DR WEST #300	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	33.97997	-118.39375	Energy plan check for a medical office T.I no exam room involved; Scope includes new lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10819	16041-10001-13008	10352 N GOTHIC AVE	91344	12	204B137   137	2679024026	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM			PC Approved	05/04/2016 12:00:00 AM	ADDRESS	34.25905	-118.48874	05/04/16Changes to an approved set of plans. Changes include adding the performance meter to the single line diagram. NOTE: Permit is paid under pcis#16041-10000-13008(((((PV1, rooftop solar installation 11kW AC.   (35) SPR327NE-WHT-D     (1) SB6000TL      (1) SB5000TL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10820	10041-10000-22580	13720 W RIVERSIDE DR	91423	2	168B157   318	2269025002	C2-1, C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00, 1287.02	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.15674	-118.43273	TI REMODEL OF (E) RETAIL SPACE - SPORTS AUTHORITY -INCLUDING DOORS, PARTITIONS, CEILING, FIXTURES, LIGHTING, MEP WORK; 46,432 SQ (BASEMENT TO 2ND FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10821	19041-20001-12667	1006 N CHANTILLY ROAD	90077	5	144B149   264	4369036011	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM			PC Approved	06/17/2019 12:00:00 AM	ADDRESS	34.08957	-118.45467	Expedite per applicant request Plan check for Tesla battery back up system installed into existing PV. Install 2 Tesla Power Wall 2.0 13.5KWh, Total battery back up 27KWh connected to existing 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10822	18041-10000-18977	11150 W SANTA MONICA BLVD ste 500	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM			Corrections Issued	05/22/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	Energy plan check for an office T.I. Scope includes new lighting and equiptment ;total area is 13,987 SQ FT. All new load under 400Amp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10823	12041-20000-14516	2115 N HILLHURST AVE	90027	4	150B197   125	5590003037	C4-1D	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.11039	-118.28764	T.I. to to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10824	13041-20000-29812	12042 W WICKS ST	91352	6	195B165   207	2631019030	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.2328	-118.39514	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. TOTAL OF 18 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10825	16041-20000-29027	18825 W SATICOY ST	91335	3	186B121    91	2103016040	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.20853	-118.54321	Plan check for power and energy. ADDITION OF [BANQUET HALL WITH KITCHEN SCHOOL  CLASSROOMS AND  WITH ROOF TOP PLAY AREA FOR THE SCHOOL] TO THE EXISTING CHURCH BUILDING. New 800A distribution fed off existing 1600A service. 10,097sqft indoors. 4,061sqft outdoors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10826	13041-10000-20660	3441 S MCCLINTOCK AVE	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			Reviewed by Supervisor	08/23/2013 12:00:00 AM	ADDRESS	34.02421	-118.28812	INSTALLATION OF NEW LED SCOREBOARD TO UPPER (2) FLOORS OF AQUATICS CENTER BUILDING. PLANS SUBMITTED TO BUILDING; WAITING FOR APPROVAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10827	12041-10000-20663	4233 N SHADYGLADE AVE	91604	2	165B165   817	2367007019	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2012 12:00:00 AM			Reviewed by Supervisor	12/27/2012 12:00:00 AM	ADDRESS	34.14776	-118.40203	10.150 kw roof mounted PV system for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10828	17041-10000-04145	6414 S MCKINLEY AVE	90001	9	105B205  1037	6007015027	M3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM			PC Info Complete	05/23/2017 12:00:00 AM	ADDRESS	33.98126	-118.26127	VOID DUE TO LOSS OF PLANS. Pc for  title-24, Energy only.Socpe includes new lights and receptacles. Total affected area is 9380 sq.ft.building app # 16016-10000-30189	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10829	17041-20000-43118	257 S MARIPOSA AVE	90004	10	135B197   154	5518007026	C2-1, R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.06962	-118.29936	Plan check for power and energy. New 7 story, mixed use building with 6 residential levels (121 units) over retail and retail parking at ground floor level . 2 levels of sub-terranean residential parking. 3,000A 208/120V 3ph 4w service. 3 typical units. Title 24 area: indoor-76,937sqft; outdoor-19,434sqft. Project is located in methane buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10830	15041-10000-24393	1608 S SAWTELLE BLVD	90025	11	129B149   347	4261007022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.04692	-118.44861	Energy plan check for an office T.I . in the one story building. Scope includes new light, receptacles, and (1) panel; Total area is 5332-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10831	16041-10002-45243	8654 N MASON AVE	91306	3	195B109   357	2781007024	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Issued	01/18/2017 12:00:00 AM	ADDRESS	34.22794	-118.57961	PC AND PERMIT FOR ADDITION OF 2 MODULES. TOTAL SYSTEM NOW USES 20 MODULES. MODULE TYPE CHANGES TO 280W PV MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10832	14041-10000-29471	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008023	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Public Safety Only			10/23/2014 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.05001	-118.25963	NEW FIRE Warning SYSTEM FOR NEW 900 ROOMS wilshire grand HOTEL. Sheets FA-00.1, FA-00.4I, and FA-00.6A are modified and attached to the front of the plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10833	13041-10000-21438	1245 W WILSHIRE BLVD 2ND FLOOR	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.05373	-118.26606	PLAN CHECK POWER AND ENERGY.  T.I. TO PROVIDE AN AMBULATORY SURGICAL CENTER/OSHPD III WHICH WILL CONTAIN 8 OPERATING ROOMS, 28 PRE/POST OPERATING BEDS AND SUPPORT AREAS. HIGH RISE MEDICAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10834	11041-20000-03194	1 S LMU DR medium vol-tage swich	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	05/18/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	replace medium voltage swich 4160 volts with same size	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10835	17041-10000-45720	633 N SANFORD AVE	90744	15	030B209   385	7424019044	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	33.77862	-118.25072	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10836	14041-20001-11029	2800 N BEACHWOOD DR	90068	4	156A189   172	5583013015	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.1214	-118.32171	Modifications to approved set.  Removal of east-facing string array and load center.  $0 plan check submittal fee is due to Senate Bill SB-1222.  (((Roof mounted PV system with microinverters.  System size 4.32KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10837	18041-20000-37020	16410 W BOSQUE DR	91436	5	165B137   572	2291016018	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.1447	-118.49077	Plan check for a PV1 roof-mounted PV system. System size is 14.625 kWdc/13.8 kWac and consists of (2) inverters, (45) modules, (2) load centers, and (2) Tesla PowerWalls.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10838	15041-20000-39784	800 W OLYMPIC BLVD 4TH FLR	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.04484	-118.26453	T-24, PC FOR ENERGY ONLY. TI TO EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES ADDING NEW LIGHTING. TOTAL AREA IS 334 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10839	17041-10000-42133	6270 W 96TH ST	90045	11	093B165   131	4124025049	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Closed	02/06/2020 12:00:00 AM	ADDRESS	33.94867	-118.39478	replace outdoor luminaires with led typeplan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10840	15041-10000-20349	19602 W LANARK ST	91335	3	189B117    95	2105003006	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.21785	-118.56051	PV1, INSTALL 9.81 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (30) MODULES: SUNPOWER SPR327NE-WHT-D(3) INVERTERS: SMA SB3000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10841	18041-20000-08756	5400 W HOLLYWOOD BLVD UNIT A	90027	13	148-5A193 139	5544021029	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.10152	-118.3074	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENENT. PHARMACY. UNIT ABUILDING PERMIT # 18016-20000-07354	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10842	14041-20000-27412	1985 E ZONAL AVE SUITE 304	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.06159	-118.20463	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING. ADDING LIGHTING TO EXISTING POWER EQUIPMENT.  1391 SQFT. WORK TO BE PERFORMED ON THE THIRD FLOOR SUITE 304.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10843	11041-20000-06490	5825 W SUNSET BLVD	90028	13	147A191    51	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.09824	-118.3165	PLAN CHECK T24 ENERGY FOR NEW LIGHTS ALONG ROOFTOP OF HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10844	18041-20001-38133	18325 W SHERMAN WAY	91335	3	183B125   109	2119023007	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.20129	-118.53263	01-28-2019 Changes to an approved set of plans, Changes include update Title 24 calculation and remove unit equipment and add 90 min battery back up in the the lighting fixture, all changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10845	15041-10000-10501	750 W 7TH ST 3RD FL	90731	15	015B197   473	7451035020	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Expired	05/03/2017 12:00:00 AM	ADDRESS	33.73798	-118.29338	FIRE ALARM SYSTEM MODIFICATION: ADDING 34 DEVICES. SCOPE OF WORK : 5,775 SQ. FT.	N	N	Express Permit	06/10/2024 12:00:00 AM
10846	13041-20001-19172	3584 S FIGUEROA ST GND FLOOR	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	((Changes made to approved T24. Added new fixture))T24 FOR EXISTING MIXED USE BUILDING. SCOPE OF WORK IN THE GYM AREA ON THE GROUND FLOOR. TOTAL SQRFT 4224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10847	17041-10004-39640	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM			PC Info Complete	12/23/2019 12:00:00 AM	ADDRESS	33.94571	-118.38857	Changes to an approved set of plans. All changes are cloudeded under delta 9. Changes include adding an  transformer, new panels, and relocating loads on the single line diagram, and relocating panels to roof-top.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10848	19041-10000-08182	6922 W HOLLYWOOD BLVD 1ST FLOOR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.10137	-118.34103	TI IN EXISTING LOBBY ON THE FIRST FLOOR. INSTALLING NEW LIGHTS INDOOR AND OUTDOOR. T-24 ENERGY ONLY.SCOPE INCLUDES NEW CIRCUITS AND NEW PANELBULDING PERMIT: 18016-10000-36653	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10849	19041-20000-44281	939 N BLUEGRASS LANE	90049	11	138B137   135	4493021014	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Issued	10/29/2019 12:00:00 AM	ADDRESS	34.0763	-118.48623	Plan check for PV roof mounted system, PV system size: 18.24KW DC, 16.4KW AC with 57 PV Modules and 2 inverters(11.4KW and 5.0KW) supply side connection.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10850	15041-10000-40642	300 S SANTA FE AVE STE E	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	T-24, TI TO AN (E) TENANT SPACE IN MIX USE 6 STORY BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1595.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10851	11041-10000-17315	6600 W SUNSET BLVD	90028	13	147A185    65	5547024011	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	34.09782	-118.33334	T.I.  Existing 7-Eleven.  Replacing the existing light fixtures with LED fixtures in the retail area only.  PLan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10852	15041-20000-31167	812 W 165TH PL	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	ADDRESS	33.88061	-118.28977	Plan check for Greenhouse enclosure on 2nd floor. Plan check for energy only. Adding new lighting. Total sqft. 1,134.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10853	19041-10000-52308	21304 W VELICATA ST	91364	3	171B105  1174	2167008008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Issued	12/18/2019 12:00:00 AM	ADDRESS	34.1612	-118.595	NEW PV1 INSTALLATION 11.34 KWdc (10KWac) USING 36 QP315 MODULES, 36 SE P400 POWER OPTIMIZERS & 1 SE10000H-US CENTRAL INVERTER. CONNCETED TO AN EXISTING 200 AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10854	17041-10000-20744	1801 E CENTURY BLVD	90002	15	091-5A215  62	6048035904	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.94578	-118.24058	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10855	11041-10000-09425	10000 W FOOTHILL BLVD	91342	7	210B181   168	2550014002	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM			PC Approved	05/10/2011 12:00:00 AM	ADDRESS	34.27275	-118.34595	CHANGING LIGHTING IN DINING AREA OF CHURCH.  T-24 OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10856	14041-20000-16824	515 S FIGUEROA ST SUITE 1100	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Info Complete	06/23/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	PC FOR TITLE 24 ENERGY AND EMERGENCY IN AN EXISTING HIGH RISE BUILDING. NEW LIGHTING, FIXTURES FOR SUITE 1100.  ALL CIRCUITS ARE EXISTING NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10857	15041-10000-11466	25825 S VERMONT AVE PHASE B	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM			PC Info Complete	04/17/2015 12:00:00 AM	ADDRESS	33.78808	-118.29535	EXTERIOR SIGNAGE FOR KAISER PERMANENTE.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10858	14041-10000-27323	14840 W RUNNYMEDE ST	91405	6	186B149   476	2218013002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.20562	-118.45671	Standard plan PV1, 6KW roof-mounted system including: (1) 6KW Solaredge inverter, (27) Kyocera KD255 module and Solaredge P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10859	14041-10000-10640	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	PLAN CHECK FOR ENERGY ONLY FOR LIGHITNG DONE IN THE COURTYARD AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10860	19041-10000-48835	13712 W OTTOMAN ST	91331	6	192B157    90	2637007015	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Closed	06/02/2021 12:00:00 AM	ADDRESS	34.22649	-118.43096	[EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 7.44KW DC/ 7.6KW AC,  8 MODULES (SLA-M300), 8 POWER OPTIMIZERS (P320), 1 CENTRAL INVERTER (SE7600H-US), 1 ESS (TESLA POWERWALL), 2 LOAD CENTER PANEL BOARDS CONNECTED WITH EXISTING SERVICE OF 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10861	15041-10000-27725	11261 N EL DORADO AVE	91331	7	210B153   267	2616021057	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.27433	-118.43434	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.2KWAC. 47 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10862	19041-10000-31830	11231 S LA CIENEGA BLVD	90045	11	087B173    98	4129038022	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.93218	-118.37028	REPLACE OUTDOOR AND INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10863	15041-20001-36370	7240 N CORBIN AVE BLDG 1	91335	3	186B117   912	2116001090	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.20249	-118.56208	EXPEDITE PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL APARTMENT BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 6KWac. (24) MODULES-CANADIAN SOLAR CS6P255P(1) INVERTER-SUNNY BOY SMA SB6000US-12(1) 125A SUBPANEL)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10864	14041-10000-32374	7354 N VALJEAN AVE	91406	6	186B137   251	2205025013	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.20464	-118.48576	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH  NEW LED FIXTURES. TOTAL AREA 3702 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10865	14041-10001-16589	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	33.94221	-118.40701	REVISIONS TO PERMITTED SET OF PLANS: ADDED CFSD CKT FOR ROOMS #4112 AND 4113AND REMOVE GROUND CONNECTION OF TGB TO BUILDING STEELTI in terminal 4 in LAX.  Plan check for power and lighting.  Total area = 1,200 sq. ft.Provide lighting, electrical distribution, 20 kVA UPS system, and power for 5 renovated spaces used as IT rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10866	19041-10001-02288	961 S ELDEN AVE 1-45	90006	1	129B197    32	5076003031	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.05373	-118.28798	EXPEDITE FEEPLAN CHECK FOR ROOF MOUNTED 27.6KVA PV2 SYSTEM CONSISTING OF 3 CENTRAL INVERTERS ((2)SE10000H-US&(1)SE7600H-US) WITH 75 MODULES USING P400 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10867	12041-10000-16819	133 N ROBERTSON BLVD	90048	5	138B169   277	4334001016	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			PC Approved	08/14/2012 12:00:00 AM	ADDRESS	34.07616	-118.38387	PLAN CHECK FOR T24 ENERGY FOR NEW OUTDOOR LIGHTING INSTALLED.  T.I. OF EXISTING RETAIL SPACE. REMOVED AND REINSTALL NEW LIGHTING, NO INCREASE IN CONNECTED LIGHTING LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10868	17041-20001-18727	4525 W WILSHIRE BLVD	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	04-13-2018 Changes to an approved set of plans. Changes include additional of lighting in the lobby  and break room. Change has been clouded. Plan check only,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10869	19041-20000-21960	12424 W WILSHIRE BLVD ste 1050	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.04135	-118.47058	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10870	12041-10000-29865	8950 N WOODLEY AVE	91343	12	195B141   185	2672002002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.23343	-118.48487	5.8 KW ROOF MOUNTED PV FOR A SINGLE FAMILY. (X-FORMERLESS INV)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10871	13041-10000-24265	20520 W DUMONT ST	91364	3	171B109   438	2166018001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.16091	-118.58107	PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 12.74KW ON PV STANDARD PLAN (14KW LIMIT), 2 STORY-HOUSE. 52 MODULES:TRINA TSM-245PC051 COMBINER BOX: STG-CBRH-6-A 1 INVERTER: FRONIUS IG PLUS V 10.0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10872	16041-20001-29228	13358 W CHANDLER BLVD	91401	4	171B157   148	2344018035	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.16818	-118.42455	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 13.8 kWac and consists of (55) modules, (55) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10873	17041-10000-39491	13025 W AZTEC ST	91342	7	228B161   481	2511030031	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2017 12:00:00 AM			Corrections Issued	11/01/2017 12:00:00 AM	ADDRESS	34.32084	-118.41633	PC FOR GROUND MOUNTED PV IN SFD. SYSTEM SIZE 6.4 KWDC/ 6.0KWACSCOPE INCLUDES 20 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10874	19041-10000-15540	1779 E 109TH ST	90059	15	088-5A215 621	6069004030	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM			Corrections Issued	04/26/2019 12:00:00 AM	ADDRESS	33.93719	-118.24087	PC FOR PV FOR SFD.SCOPE INCLUDES MODULES AND OPTIMIZERS WITH CENTRAL INVERTER. TOTAL SYSTEM SIZE 3.57 KWDC /3 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10875	10041-10000-16424	11827 W VENICE BLVD	90066	11	114B157   942	4234016001	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM			PC Approved	08/23/2010 12:00:00 AM	ADDRESS	34.00775	-118.42664	PC ONLY. T.I. in an existing building.  Plan check for T24 and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10876	16041-20000-08558	18133 W VENTURA BLVD 201	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. 2ND FLOOR OF A 4-STORY MED BUILDING. Medical outpatient center. 13,973sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10877	19041-10000-17343	581 N VIA DE LA PAZ	90272	11	126B125   691	4412017018	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.04009	-118.52903	(ePlan)  Install New 5.2 kW AC Rooftop solar system on (E) SFD,  (1)  Energy Storage System @ 13.5KWH, (1) New 200A Load Center. Main Service Panel is 400A Split Bus	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10878	15041-10000-43940	10993 W WELLWORTH AVE 1-8	90024	5	132B149   175	4324003010	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			12/30/2015 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	05/31/2022 12:00:00 AM	ADDRESS	34.05634	-118.44604	Full plan check for a new 8 unit 5-story apartment building with mezzanine over 2 levels basement; Total 4-typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10879	15041-20000-10020	12465 W OSPREY LANE unit 1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	33.97923	-118.41018	Plan check for PV roof mounted system for tri-plex unit #1 with system size: 1.84kW. PV clearance shall apply to Unit #2 and # 3 for address 12465 osprey Lane, Los Angeles CA 90094	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10880	14041-10000-08616	25965 S NORMANDIE AVE LEVEL 3	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	T24 FOR EXISTING MEDICAL BUILDING. RETROFITTING LIGHTS ONLY. CONVERTING FLOURESCENT FIXTURES TO LED FIXTURES. RETROFIT KIT IS UL LISTED FOR THE APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10881	11041-20000-03800	5601 N DE SOTO AVE 2nd floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	05/24/2011 12:00:00 AM		Issued	05/24/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check power. T.I. for Kaiser Foundation structure systems upgrade for ambulatory care facilities.  Install subpanels, branch circuits in the emergency system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10882	19041-20001-53203	12681 W JEFFERSON BLVD	90066	11	102B161    25	4211009025	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			Reviewed by Supervisor	01/02/2020 12:00:00 AM	ADDRESS	33.97836	-118.41626	Expedite per applicat requst Plan check for PV roof mounted system, PV System size: 432.525KW with 395 PV Modules and 4 inverters(100KW) Suplly side connection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10883	18041-10000-26613	3415 W BELLEVUE AVE	90026	13	141A201   259	5401008014	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1959.03	Electrical	Electrical	Apartment			07/17/2018 12:00:00 AM			PC Info Complete	07/17/2018 12:00:00 AM	ADDRESS	34.07952	-118.28143	PC FOR NEW FIRE ALARM FOR A 14 UNITS APARTMENT BUILDING (4 STORY). SCOPE INCLUDES 84 DEVICES AND A 3 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10884	16041-10001-22519	13274 W FIJI WAY 300	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	33.97902	-118.43558	T-24, PC FOR A LOST SET OF PLANS. SCOPE INCLUDES NEW LIGHTING FOR COMMON AREA AND ELEVATOR LOBBY AREAS. TOTAL AFFECTED AREA IS 693 SQ. FT.Note: original application is under PCIS#16041-10000-22519	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10885	15041-20000-29964	20654 W SAN JOSE ST	91311	12	207B109   610	2707011001	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Expired	10/06/2017 12:00:00 AM	ADDRESS	34.26065	-118.58386	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10886	15041-20000-16259	936 S OLIVE ST UNIT 356	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Master permit for 20 unit apartment. Solar clearance shall apply to address 936 Olive St. Units 246, 248, 249, 250, 252, 254, 255, 256, 257, 346, 348, 349, 350, 352, 353, 354, 355, 356 and 357. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10887	10041-10000-08501	8985 W VENICE BLVD	90034	10	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2701.00	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	ADDRESS	34.02733	-118.39241	NEW TENANT FOR C-1C RETAIL STORE. C-1A HAS TWO NEW PANEL WHICH ARE NOT PART OF THE SCOPE. SWITCH BOARD IS PART OF THIS SCOPE EXCEPT THE NEW PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10888	14041-10000-24993	7723 N DENSMORE AVE	91406	6	189B141   258	2206010040	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.21113	-118.47725	Title 24 plan check only.Remove HID light fixtures and replace with new LED fixtures.Total square footage: 952 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10889	16041-20001-40161	11601 N DE CELIS PL	91344	12	213B137   418	2610011008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	11/22/2016 12:00:00 AM	ADDRESS	34.28107	-118.49626	Expedited per applicant request.Plan check for the addition of a PV system onto an existing PV1 roof-mounted PV system. System addition size is 3 kWac for a total system size of 6 kWac. System addition consists of (1) inverter, (14) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10890	19041-10001-05099	3925 W SUNSET BLVD	90029	13	145-5A203 317	5429013030	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM			PC Approved	06/27/2019 12:00:00 AM	ADDRESS	34.09246	-118.28011	change to an approve set, change is under delta 1. original scope:Tenant Improvement to an restaurant. Installing new lights & 600Amp Panel. inspection under original Permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10891	17041-10000-01489	8000 W MELROSE AVE	90046	5	141B177   613	5527015001	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.08363	-118.36391	PC for energy for retail space at 3456 sqft with no change in occupancy. PC for new lights and receptacles.additional express permit under: 17041-20000-10401	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10892	19041-10000-19550	1546 S EDRIS DR	90035	5	129B165   398	4306013011	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.05105	-118.39739	PV1. NEW 7.6 kW AC ROOFTOP SOLAR SYSTEM CONSISTING OF 32 AC MODULES ( SUNPOWER 327). SCOPE INCLUDES 125A SUBPANEL .Note: Panel unpgrade shall be pulled under express permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10893	14041-20001-02178	8445 N OAKDALE AVE	91306	3	192B113   295	2782010004	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.22341	-118.56682	(((EXPEDITE FEESs)))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10894	15041-10000-29796	6701 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.93211	-118.40783	PC FOR POWER ONLY, SCOPE INCLUDES THE REPLACEMENT OF LOAD IN A KITCHEN FACILITY FOR LA X. TOTAL AMPS>400 AMPS. CHANGES ON NOTE 1, ELECTRICAL EQUIPMENT TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10895	16041-10001-25617	17250 W SATICOY ST	91406	6	186B133   238	2203017042	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM			Corrections Issued	11/21/2017 12:00:00 AM	ADDRESS	34.20822	-118.50895	Plan check only for changes to approved set of plans - scope are clouded under delta 9 - chages include removal of proposed panels, renaming panels,  and redesignation of circuits on panels. Original permit under 16041-10000-25617Full Plan TI to existing Ralphs commercial building grocerystore. Existing main service, adding 2 new panels and tranformers. Adding new load to existing panels. Newly connected load is greater than 400 amps. Total sqft = 2850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10896	19041-10000-05097	245 S CONWAY AVE	90024	5	138B153    31	4359008015	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.07821	-118.43476	PC FOR NEW 2 STORY SINGLE FAMILY DWELLING WITH 600A NEW SERVICE 2P 120/240V.SCOPE INCLUDES NEW PANELS, CIRCUITS AND LIGHTS. Plan Check Only. Building Combo Permit: # 14010-10000-01874	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10897	16041-10000-23138	6307 S CONDON AVE	90056	11	105B177   533	4002007021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.98182	-118.3602	PV1. NEW SOLAR SYSTEM WITH 17 MODULES AND 17 MICROINVERTERS. TOTAL SYSTEM DC SIZE 4420 W.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10898	17041-10000-37475	14615 W OXNARD ST	91411	6	177A151    94	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Closed	06/13/2019 12:00:00 AM	ADDRESS	34.17955	-118.45137	PC for new fire alarm system for 106 devices and one FACP, one annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10899	15041-20001-03031	12481 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9791	-118.41047	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10900	13041-20003-35606	11995 W BLUFF CREEK DR BLDG #4	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	CHANGES TO APPROVED SET OF PLANS. CHANGE FROM COPPER TO ALUMINUM FEEDERS. ALL CHANGES CLOUDED DELTA VE FOR VALUES ENGINEERING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10901	17041-10000-36172	1575 N GOWER ST 3rd flrt-ste C	90028	13	148-5A189 330	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	PC for power and energy for first time tenant in office space sutite C. Installing new circuits, lights, receptacles and equipment. Total area is 3780sqft. B# 17016-10000-25279	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10902	13041-20000-08152	2029 S CENTURY PARK EAST STE 550	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for energy and emergency lighting. Office ti. High rise commercial. Sitrin Capital Management. Suite 550 (5th floor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10903	15041-20000-01201	131 E 50TH ST	90011	9	111A205   273	5109004013	RD2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	33.99755	-118.27331	NEW 1 STORY, SCHOOL BUILDING, MIDDLE SCHOOL. TYING INTO EXISTING SERVICE. PLAN CHECK FOR POWER AND ENERGY. PARKING LOT WITH 33 PARKING SPACES, E AND B OCCUPANCY. TOTAL SQFT 41,300.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10904	19041-10000-39135	762 S SERRANO AVE	90005	10	132B193   571	5093014070	(T)(Q)C2-1	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Apartment			09/27/2019 12:00:00 AM	03/15/2021 12:00:00 AM		Permit Finaled	08/24/2023 12:00:00 AM	ADDRESS	34.05801	-118.30642	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW NEW MIXED USE BUILDING WITH 157 RESIDENTIAL UNITS OVER GROUND FLOOR RETAIL AND RESTAURANTS OVER 2 LEVELS SUBTERRANEAN PARKING.  SCOPE OF WORK INCLUDES TWO SERVICES FOR THE RETAIL AND RESDIENTIAL SECTION, THE RETAIL SECTION IS A 2500A SERVICE (120/208 3P 4W) FEEDING AN EV CHARGER PANEL. THE RESEDNTIAL SECTION IS  A 4000A SERVICE (120/208 3P, 4W). TOTAL AFFECTED AREA IS 86,706.B#: 19010-10000-61792NOTE: FEES ADJUSTED FOR PRE CUT CHECK, PLAN CHECKER TO VERIFY FEES DURING PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10905	16041-30000-01831	1999 S AVENUE OF THE STARS # 3425	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Title 24 plan check only.  Total area = 2,495 sq. ft.T.I. to existing commercial office highrise.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10906	12041-10000-21118	4181 S LINCOLN BLVD	90292	11	105B153    57	4229003033	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2012 12:00:00 AM			Plans on Hold	10/01/2012 12:00:00 AM	ADDRESS	33.98668	-118.44457	INSTALLATION OF A   5.2KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10907	19041-10001-20446	953 N SYCAMORE AVE 6th Flr	90038	4	144B181   671	5531015010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			Reviewed by Supervisor	12/09/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	***FEE ESTIMATE ONLY***DELTA 2 CHANGES TO APPROVED SET. MAJOR CHANGES TO THE SINGLE LINE DIAGRAM, POWER AND LIGHTING PLANS. SCOPE INCLUDES UPGRADING TRANSFORMER TO 150KVA ,  ADDITION OF A 75KVA TRANSFORMER, NEW PANEL RP6F, UPDATING LOADS ON ALL OTHER PANELS AND REVISING POWER AND LIGHTING FLOOR PLANS. DETAILED WRITTEN NARRATIVE IS PROVIDEDFull plan check for a 1st time tenant OFFICE  T.I. located on the 6TH FLOOR  of a high rise building. Scope includes new lighting, and equipment with a total lighting area of 19,610-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10908	17041-10000-23620	3361 N ANDRITA ST LOT 10	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 10 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05792	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10909	17041-20000-14876	5900 W WILSHIRE BLVD ste 2110	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.06237	-118.35809	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10910	14041-20000-24835	7006 S HOOVER ST UNIT 2	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #2.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10911	19041-20000-09229	15760 W VENTURA BLVD STE650/670	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.1552	-118.47684	T24 FOR EXISTING COMMERCIAL HIGH RISE. TOTAL SQUARE FOOTAGE = 3210 SF. LIGHTS AND OUTLETS ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10912	15041-20001-26206	7249 N BAIRD AVE	91335	3	186B125   920	2118028047	(Q)R3-2	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			08/12/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.20259	-118.53747	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM.  CENTRAL INVERTER SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 12KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10913	12041-10000-03569	10600 N BAIRD AVE	91326	12	207B125   394	2728022002	RE11-1	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2012 12:00:00 AM	03/02/2012 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.263	-118.5371	Plan check roof mounted 9.36KW  photvoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10914	11041-10001-26372	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	33.98645	-118.44148	REVISION TO APPROVED PLAN CHECK T24 ENERGY OUTDOOR LIGHTING. CHANGES TO T24 CALCULATION, ADD FIXTURES, AND CHANGE FIXTURE TYPE. LIGHTING IN WEST END AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10915	15041-20002-30907	1601 N HOBART BLVD 1-54	90027	13	148-5A195 289	5544020010	[Q]R4-2	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.09995	-118.30593	1/29/2019changes to an approved set of plans.  changes to reflect current field conditions.  this is plan check only.  changes noted delta 7,8,9.  ((((PLANCHECK FOR POWER AND ENERGY. NEW 54 UNIT FOUR (4) STORY LEVEL RESIDENTIAL APARTMENT BUILDING (SUBTERRANEAN PARKING, COMMUNITY ROOM & OFFICE.  BUILDING SUBMITTAL ON 2008 CODE.; 13010-10000-04281. FIRE ALARM VARIANCE HAS BEEN SUBMITTED))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10916	17041-20001-12428	6060 W CENTER DR #400	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Issued	07/21/2017 12:00:00 AM	ADDRESS	33.97602	-118.39073	7/21/17changes to an approved set of plans.  changes noted delta 5.  changes include updated plan to reflect field conditions in the 3rd and 4th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10917	13041-20000-24377	11175 W SANTA MONICA BLVD 5th floor	90025	5	129B149   297	4324035029	M1-2	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.04739	-118.44609	Existing office building, remodel lights and power.  Hi-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10918	18041-10000-07512	400 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Info Complete	03/29/2018 12:00:00 AM	PIN	33.94094587	-118.40577128	PC FOR TI FOR A PILOT LOUNGE AT TERMINAL 4 FOR T-24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS , LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 10817 SQ.FTB#17016-10000-32025	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10919	18041-10000-27685	2131 W COLORADO BLVD	90041	14	162A223    98	5671010003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.13937	-118.21279	Change of use from Retail to Restaurant. Existing 400 Amp service & panels. Install new circuits.Plan Check for T-24 Energy ONLY.Bldg Permit: 18016-10000-07370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10920	19041-20000-12856	13652 N SIMSHAW AVE	91342	7	228B161   602	2580013010	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.32013	-118.41373	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 7.56KW DC/5KW AC. SCOPE OF WORK INCLUDES (21) SUNPOWER SPR-X22-360 PV MODULES WITH SEP400 OPTIMIZERS, AND A SE5000H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10921	17041-10000-11115	734 S CATALINA ST	90005	10	132B197   334	5094009028	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.05875	-118.29524	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  1375 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10922	14041-20000-35319	550 S HOPE ST SUITE 750	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	TI to an existing high rise commerical buildings. Adding new lighting and controls to Suite 750 to existing pannels. Plan check for Title 24 and emergency lighting. Total SQFT 5698.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10923	18041-10000-21486	11488 W KAGEL CANYON ST	91342	7	213B169  1015	2530019054	(T)(Q)RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1041.24	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.27918	-118.38217	Install new PV1 rooftop, 3.8 kW AC system. (11) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10924	14041-10000-03965	7800 S AIRLANE AVE PV1	90045	11	099B169   445	4106025017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	33.96869	-118.38978	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 125A MAIN PANEL. SYSTEM IS TRANSFORMERLESS, SIZED @ 3.3 kW DC, WITH (10) SUNPOWER SPR-x21-335 , IN 2 STRINGS, (1) POWERONE 3kVA INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10925	14041-20001-24071	9670 N DONNA AVE	91324	12	201B121   434	2762032029	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM			PC Approved	09/08/2014 12:00:00 AM	ADDRESS	34.24691	-118.54739	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. Interconnect with MSP. System size: 6kW.(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(27) Kyocera KD255GX-LFB3 pv modules(27) SolarEdge P300 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10926	12041-10000-21478	3820 S MARCASEL AVE	90066	11	114B157  1263	4214017001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.00607	-118.42756	4.16 kw roof mounted PV for a single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10927	14041-20001-24103	1860 N FULLER AVE	90046	4	150B181   514	5572030029	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	34.10507	-118.34882	SUPPLEMENTAL PERMIT TO MODIFY LIGHTING FIXTURES UNDER PERMIT NUMBER 14041-20000-24103.TI TO AN EXISTING APARTMENT BULIDING TWO FLOORS.  ADDING LIGHTS AND NEW CIRCUITS TO EXISTING PANELS.  WORK TO BE DONE ON THE LOBBY FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10928	11041-10000-13423	4207 W BEVERLY BL	90004						WILSHIRE				Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM				T.I.  Pizza Hut to occupy existing retail space.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10929	12041-10000-13489	12200 W OLYMPIC BLVD 4th Floor	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/11/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.03195	-118.45506	<<<<<ON THE 4TH FLOOR, VACATED TENANT OFFICE SPACE TO BE TAKEN OVER BY ADJACENT EXISTING TENANTPLAN CHK IS FOR TITLE 24 AND 1 EA  EMERGENCY CKT>>>>>  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10930	14041-10000-17556	4954 N VAN NUYS BLVD #110-#200	91403	4	171A151   258	2248007143	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.1608	-118.44849	plan check for power and energy. medical office. BLDG#14016-20-08356: interior TI to suit #110 and 200  office spaces  at first and second floor of two story Type V-A   building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10931	16041-20001-37420	6840 N DE CELIS PL	91406	6	183B137   536	2225001***	[T][Q]RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.19497	-118.4944	expedite per applicant.pv1install pv system sized 3kw interconnected with msp.This is an additional system to an existing 3kw.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10932	13041-10000-23342	746 E WASHINGTON BLVD	90011	9	121-5A209 188	5131006010	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	10/24/2013 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	PIN	34.02671801	-118.25613803	POWER PLAN CHECK; EXISTING COMMERCIAL BUILDINGS USED AS MANUFACTURING WAREHOUSE AND ELECTRONIC TESTING/MANUFACTORING; RECEIVING NEW 800A, 3-PHASE, 2-METER, STAND-UP, OVERHEAD FED SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10933	12041-20000-30420	2920 N BEVERLY GLEN CIR	90077	5	156B153    17	4382030065	RE15-1VLD-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM	12/31/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.12758	-118.44341	Change to lighting in an existing bank in the COMPLETE building.  Occupancy load is less han 99 and load is less than 400 per applicant.  PLAN CHECK ONLY for Energy.  There is NO Emergency lighting per applicant.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10934	11041-20000-03556	11755 W WILSHIRE BLVD # 1400	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	PIN	34.04869377	-118.46238681	TI enegy plan check . # 1400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10935	17041-10000-18820	2706 W WILSHIRE BLVD	90057	1	133-5A201  94	5141011016	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.06093	-118.28296	PC for energy only, Outdoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 16,250 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10936	09041-10003-18735	9961 W LIEBE DR	90210		156B153   251	4382019013	RE40-1-H		Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES		Electrical	Electrical	1 or 2 Family Dwelling			01/19/2012 12:00:00 AM			PC Info Complete	01/19/2012 12:00:00 AM	ADDRESS	34.1212	-118.43852	"DELTA 2 Changes to the approved plans.   Change the 150KVA transformer for the house to 50KVA for the ""guest house"" ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10937	18041-10000-48516	3168 E WABASH AVE 1-14	90063	14	129A229    86	5178001032	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Apartment			12/21/2018 12:00:00 AM	01/06/2020 12:00:00 AM		Issued	01/06/2020 12:00:00 AM	ADDRESS	34.04795	-118.19265	14 UNIT APARTMENT BUILDING. LAUNDRY CLOSET, REMODELED KITCHEN AND BATHROOMS.NEW 800AMP SERVICE, PANELS, CIRCUITS, ETC.BUILDING PERMIT: 18016-10000-40832	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10938	16041-20000-20237	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	PLANCHECK FOR T24 OUTDOOR LIGHTING. BALDWIN HILLS CRENSHAW PLAZA.  1,114,765 SQFT OF ILLUMINATED HARDSCAPE AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10939	15041-10000-20854	6260 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Expired	09/13/2017 12:00:00 AM	ADDRESS	34.18497	-118.60418	New 265-device fire alarm system at Westfield West Valley parking facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10940	19041-20000-37620	17344 W KINGSBURY ST	91344	12	207B129   665	2733026003	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.26345	-118.51253	PV1. INSTALL 7.56 KW DC SOLAR SYSTEM WITH (24) MODULES AND OPTIMIZERS AND (1) INVERTER (SE7600H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10941	19041-20000-24884	333 S GRAND AVE 35th Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Issued	08/16/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Tenant Improvement lighting in Restroom Upgrade. Total area: 780 sq ft. B19016-10000-18711	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10942	17041-20000-22769	15260 W VENTURA BLVD SUITE 1240	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 1240. 7861 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10943	12041-10000-23081	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM			PC Approved	09/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	"REFERENCE # 10041-10003-05975ADDITION AND ALTERATIONS TO TBIT . Core design Noitice -093 are addressed under this plan review- new circuits, panelbords ,use of existing 2"" conduit, and new feeders are all noted on submitted plans."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10944	13041-10000-07089	200 WORLD WAY T 2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	33.94558	-118.4039	13041-10000-07089PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS FOR TENANT IMPROVEMENT AT LAX TERMINAL 2. NOTE; ALL TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER. NEW WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10945	08041-10002-05798	1015 S GEORGIA ST	90015	9	127-5A205 519	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/25/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	07/16/2010 12:00:00 AM	ADDRESS	34.04518	-118.26774	( CHANGES MADE TO PREVIOUSLY APPROVED. PER MR. DAWSON AS-BUILT MUST BE UPDATED AND BE REVIEWED BY PLAN CHECK/ SOME LIGHTS RELOCATED OR ADDED OR REMOVED. SOME ADDED CKTS. SOME PANEL LOADS UP AND SOME DOWN OVER ALL LOAD IS LOWER THAN BEFORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10946	19041-20000-23269	20867 W LASSEN ST	91311	12	201B109    90	2741002005	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.25013	-118.58821	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10947	16041-20000-41559	336 W ANAHEIM ST	90744	1	030B205   429	7416033041	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	33.7796	-118.26592	PLAN CHECK FOR ENERGY OUTDOORS (PARKING LOT) ONLY.  TOTAL QUARE FOOTAGE 59981.REPLACEMENT WITH NEW LED LIGHT FIXTURES WIRING TO REMAIN.  NO NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10948	19041-10000-11970	10923 W MAGNOLIA BLVD	91601	2	171B173   573	2416005007	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	PIN	34.16516624	-118.36874511	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10949	15041-20000-19274	7619 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.20923	-118.46494	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10950	15041-10001-40734	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.04538	-118.26389	REVISIONS TO PERMITTED SET OF PLANS ALL CHANGS ARE SHOWN CLOUDED-CHANGES TO KITCHEN EQUIPMENT  AND REMOVAL OF METHANE UNDERGROUND PULL SECTION((((((((((FULL PC, TI TO AN (E) HIGH RISE  HOTEL BUILDING WITH 288 UNIT APARTMENT. SCOPE OF WORK INCLUDES THE REPLACEMENT OF ALL ELECTRICAL EQUIPMENT WITH EXISTING 2000AMP SERVICE. TOTAL SQ. FT. 57,334.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10951	19041-10000-40276	18040 W SHERMAN WAY	91335	3	183B125   226	2121023042	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.20091	-118.52659	Plan check for a new power supply with (48) fire alrm devices reconnecting to an existing fire alarm system located on the 1st floor of a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10952	12041-20000-15120	3507 S TROUSDALE PKWY	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.02187	-118.2846	New lighting and dimmer panel for auditorium as USC.  Full plan check for for lighting and power in assembly area.  Plan is incomplete.  No panel schedules provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10953	16041-10001-03370	3756 N ALTA MESA DR	91604	2	162B161   608	2384009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.13855	-118.41017	Expetited per customer request. (((PV1 roof mouted installation system to a single family home. (48) Micro Inverters, total rating: 10.32 kw, (48) Modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10954	16041-20001-04338	1207 E ADAMS BLVD	90011	9	118-5A211 348	5119022003	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	34.01763	-118.25209	RSES expedited plan check per applicant request.  PV1.  Install 5.2 kW rooftop mounted PV system.  Applicant design set plans.  (1) SolarEdge SE5000A-US transformerless inverter with power optimizers and (20) Q.PRO BFR-G4-260 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10955	17041-10000-05765	10925 W BLUFFSIDE DR	91604	2	162B173   304	2366021008	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			02/22/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.14115	-118.36774	Plan check for Title 24 T.I. in common area in existing building. Total are: 3690 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10956	15041-10000-14153	13335 W MAXELLA AVE	90292	11	108B153  1268	4230006027	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	33.98802	-118.43906	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10957	14041-10000-02327	8905 N GLENOAKS BLVD BldgA	91352	6	195B173   278	2408008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			Reviewed by Supervisor	02/04/2014 12:00:00 AM	ADDRESS	34.23033	-118.36723	pc for power and energy. 1st time tenant. Bldg A Restaurant.13016-10000-26612 description:TENANT IMPROVEMENT FOR RESTAURANT INSIDE (E) BUILDING SHELL : NEW NON-BEARING PARTITION WALLS ; NEW ACCESSIBLE RESTROOM ; NEW WALK-IN COOLER ; NEW KITCHEN ; WALL AND FLOOR FINISHES ; REFLECTED CEILING PANELS ;  PLUMBING. BUILD NEW NON-BEARING PARTITION WALLS ; MILLWORK .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10958	12041-20000-23190	13833 W VENTURA BLVD 104	91423	4	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	09/28/2012 12:00:00 AM	ADDRESS	34.1487	-118.43426	Plan check for energy and emergency lighting. Changes to approved set of plans 08041-20000-05790. Unit 104. 678sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10959	19041-10000-09131	8505 S WESTERN AVE	90047	8	097-5A193 263	6035032039	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	33.96069	-118.30921	PLAN CHECK FOR TITLE 24 ONLY FOR SCHOOL TOTAL EFFECTED AREA 9389 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10960	10041-10001-13041	533 S LOS ANGELES ST	90013	14	127-5A211  22	5148020001	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			Reviewed by Supervisor	08/07/2014 12:00:00 AM	ADDRESS	34.04536	-118.24846	PLANS ARE REVIEWED FOR COMFORMANCE TO RECENT CODE CHANGES ; PROJECT WAS POSTP[ONED AND NOW REVIVED; PERMIT TO BE OBTAINED ON INSPECTION FEE PERIODup-grade of retrofit  of seven floors over subterrean basement ; core and shell only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10961	11041-10000-25812	175 S FAIRFAX AVE	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	12/09/2011 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	New fire alarm system for a new retail building (shell only) with one control panel and 27 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10962	16041-20000-15491	4211 W MONROE ST	90029	13	141B197   162	5539015008	RD1.5-1XL	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Issued	07/01/2016 12:00:00 AM	ADDRESS	34.08576	-118.28978	Plan check for PV roof mounted system on SFD. System size: 2.5kW with 8 modules and 1 inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10963	17041-10000-00291	"7401 WORLD WAY WEST Area ""A"""	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	33.94379	-118.42359	"Plan check for Title 24 only  in existing FedDx Facility outdoor lighting.  Area ""A"" Total lighing  area: 101,502 sq ft. Part of the plan is  Aviation facilities. Aviation Facilities are Excepttion to seciton 140.7(a)"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10964	16041-10000-32517	8383 N TOPANGA CANYON BLVD	91304	12	192B101   471	2010023041	C2-1L, P-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM			Reviewed by Supervisor	10/14/2016 12:00:00 AM	ADDRESS	34.22169	-118.60632	PC FOR T24 ENERGY ONLY FOR REPLACEMENT OF LIGHTING FIXTURES IN RETAIL SPACE. REPLACEMENT GREATER THAN 10%. PROVIDING NEW T24 FOR INSTALLATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10965	19041-20001-13132	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Issued	08/26/2019 12:00:00 AM	ADDRESS	34.02198	-118.33376	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 5 ONLY. ADD NEW PANEL, TRANSFORMER, AND LIGHTS.<<<Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from warehouse to office and parking garage and the addition of a 2nd floor. Work includes a new 1,200-amp service and a total lighting area of 42,690 sq. ft.Note: Building permit has been issued under 18014-10000-04633>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10966	13041-10000-34456	1133 S LONGWOOD AVE	90019	10	132B185   865	5084023036	R2-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.05474	-118.33956	PV1, Install a 4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10967	18041-10000-04175	1754 N TAFT AVE	90028	13	150A191   378	5586034011	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.10333	-118.31458	PC for fire alarm system for three story single family. Installing 73 devices, one FACP and one annunciator. PC per applicants request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10968	13041-20000-10355	4980 S CENTINELA AVE 1-12	90066	11	105B161   122	4221021015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Apartment			04/22/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Issued	06/26/2013 12:00:00 AM	ADDRESS	33.98729	-118.41601	Plan check for new 12 unit appartment. NOT methane hazard site. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10969	19041-10000-28081	614 E CENTURY BLVD 1-4	90003	8	091-5A207 103	6050036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	PIN	33.94508743	-118.26461689	PLAN CHECK ONLY, PERMIT FEES HAVE BEEN PAID FOR UNDER SEPARATE APPLICATION. __________________________________________________________________Building 5 of 5: Note. 5 applications under 1 plan, main service located in bld # 3Full plan check for power and energy for service upgrade to 600A for 22 residential units split up into muiltple buildings. Scope of work includes a new 600A serivce, new resedintial panels, and a new 600 A distribution board. Note building has provided 5 different building numbers for each building, 5 applications were genrated  under one planELECTRICAL Buiding 1: 19041-10000-27892Building 2: 19041-10000-28073Building 3: 19041-10000-28077Building 4: 19041-10000-28079Building 5: 19041-10000-28081*Building 1 B#: 17014-40000-00543Building 2 B#:17014-40000-00545Building 3 B#: 17014-40000-00546Building 4 B#: 17014-40000-00547Building 5 B#: 17014-40000-00548*	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10970	11041-20000-15730	6601 N LANKERSHIM BLVD	91606	2	180B169   477	2322018025	C2-1VL, R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.03	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.19059	-118.38798	New Carl's Jr Restaurant. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10971	17041-20001-34647	19433 W RUNNYMEDE ST	91335	3	186B117   482	2116016065	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.20575	-118.55685	Plan check approval for derated main breaker for center-fed panel.  Approval is for interconnection details only, approval for all other components of PV system under master permit standard plan. (((Plan check for solar pv system, roof-mounted array on SFD.5.88kW ungrounded system. (21) 280W AC modules.Using standard plan.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10972	11041-20000-23488	8750 N SEPULVEDA BLVD	91343	7	195B145   409	2654012007	C2-1	North Valley	Mission Hills - Panorama City - North Hills			1175.20	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	05/23/2012 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.22986	-118.46741	T.I.  Light fixture remodel for bank.  Plan check is for energy only. SOUTH Sepulveda Blvd, not N. Sepulveda	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10973	18041-10000-32269	11538 W SAN VICENTE BLVD	90049	11	129B145    77	4265004033	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.05311	-118.46143	FULL PLAN CHECK FOR INTERIOR OFFICE TI. EXISITNG SERVICE, NEW CONNECTED LOAD > 400A, NEW LIGHTINGS AND POWER, TOTRAL AREA: 21,682 SQ.FT(B# 18016-10000-25256, 18016-10000-25261)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10974	14041-20003-13424	5601 N DE SOTO AVE 2nd Floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM			PC Approved	02/13/2015 12:00:00 AM	ADDRESS	34.17126	-118.58861	"2.13.2015 - Plan check for modifications to approved set. Remove pendant lighting from Swing room and replace with LED fixtures. Rearrange lighting in Work Area ""2992"". Update Title-24 calculations and forms to reflect changes. Changes clouded.T.I. to existhing building (Kaiser Permanente) on 2nd floor of none patience care area.  Install branch circuits and lighting.  Plan check for power and energy."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10975	17041-10000-20033	652 E 36TH ST	90011	9	117A207   322	5121005003	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Expired	09/17/2023 12:00:00 AM	ADDRESS	34.01349	-118.26326	Installation of new roof mounted solar PV system on existing single family dwelling.  Central inverter system with new 200 amp load center.  Total size = 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
10976	10041-20001-15449	1551 N WILMINGTON BLVD	90744	15	036B201   416	7414027030	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Info Complete	07/26/2011 12:00:00 AM	ADDRESS	33.79401	-118.2753	REVISION TO AS BUILD DRAWINGS - REQUESTED BY INSPECTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10977	16041-20000-45779	20922 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Issued	01/26/2017 12:00:00 AM	ADDRESS	34.21974	-118.58937	New service for a fish market. #20922.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10978	18041-10000-11176	13915 W SATICOY ST	91402	6	189B153   936	2214022023	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Issued	04/19/2018 12:00:00 AM	ADDRESS	34.21048	-118.4359	DESIGN BUILD. PC FOR TITLE 24 ENERGY ONLY FOR OFFICE T.I. TO (E)  OFFICE/WAREHOUSE SCOPE INCLUDES NEW PANEL, EQIPMENT AND LIGHTS. PARTIAL PERMIT PULLED UNDER  18041-10000-02042.  2 NEW CIRCUITS AND 2 EQUIPMENT UNITS UNDER THIS SUBMITTAL. TOTAL AFFECTED AREA 4267 SQ. FTB#17016-10000-38554	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10979	13041-20000-14958	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.06222	-118.35208	T24 FOR HIGHRISE OFFICE BUILDING. SCOPE OF WORK IN FIRST FLOOR BATHROOM ONLY. 368 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10980	17041-10000-43729	1516 N SAN PABLO ST	90033	14	135A225    64	5202004042	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.06268	-118.20282	PC FOR TI  IN A MEDICAL FACILITY AT USC. SCOPE INCLUDES NEW RECEPTACLES FOR POWER AND DATA FOR WORKSTATIONS ON FIVE FLOORS.B# 17016-10000-35999MEDICAL TI UNDER 15041-10000-06920 (WITH CHANGE OF ADDRESS ON )15041-10005-06920	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
10981	13041-10000-24783	3300 W FLORENCE AVE	90043	8	102B185   816	4012016017	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	33.97437	-118.32903	TITLE 24 PLAN CHECK ONLY. 1 STORY. 875 SQFT. AUTOSERVICE SHOP. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.  TALKED WITH INSPECTOR HENRY BAGHDASSARIAN, HE SAID IT DOESNT APPLY TO THIS BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10982	19041-10000-37323	1999 S BUNDY DR	90025	11	123B149   406	4259019007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	07/27/2020 12:00:00 AM		Issued	07/27/2020 12:00:00 AM	ADDRESS	34.03406	-118.45593	PLAN CHECK FOR FIRE ALARM SYSTEM. SYSTEM INSTALLED IN 3 FLOORS COMMERCIAL BUILDING. (1) FACP AND (982) DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10983	12041-10000-21466	3976 S COOLIDGE AVE	90066	11	114B157  1309	4214011008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.00567	-118.42102	4.16 kw Roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10984	16041-10001-37782	2252-2298 S MINER ST PV	90731		009B201     8	7440037903							Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	12/30/2016 12:00:00 AM				EXPEDITE FEESPV 2 COMMERCIAL ROOFTOP SOLAR. PC FOR TOTAL OF 3819 MODULES AND 14 CENTRAL INVERTERS. INTERCONNECTING TO NEW DWP SERVICE FOR SOLAR ONLY. THIS IS FEED IN TARRIF PROJECT (FIT). LOCATED IN METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10985	14041-10000-00777	13749 N KISMET AVE	91342	7	228B153   314	2503004013	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.32186	-118.43458	Install 4.32  kw DC roof-mounted solar array for a one story house interconnect with main service panel, (20)Modules: Benq Solar PM250M01 and micro  inverter:  Enphase energy M215. CHANGES show subpanel being used as well as jboxes on roof plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
10986	17041-10001-00457	555 W 5TH ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGED NOTED DELTA 4 AND 5 ON PLANS. CONNECTING EGRESS LIGHTING TO BUILDING GENERATOR AND CLARIFICATION THAT CODE CYCLE FOLLOWS 2013 STANDARDS DUE TO BUILDING PERMIT SUBMITTAL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10987	18041-20001-43866	3301 N LONGRIDGE TER	91423	4	159B161   304	2385010001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM			PC Approved	11/25/2018 12:00:00 AM	ADDRESS	34.13006	-118.41882	expeidtepv1install roof mounted pv system sized 11.2KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10988	16041-10001-45568	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM			PC Approved	02/15/2018 12:00:00 AM	ADDRESS	34.06047	-118.29555	"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA ""RFI 99 AND ""RFI  100"". CHANGES INCLUDE REFEEDING 100 HP FIRE PUMP AND DISTRIBUTION BOARD ""MSA"" TO NEW SERVICE LOCATED IN NORTH BUILDING. RELOCATING EV PANELBOARD AND SUMP PUMPS ON FLOOR PLANS AND  REVISING FIRE PUMP CONDUCTORS. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER. B#15014-10000-05720"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10989	18041-30000-14450	2029 S CENTURY PARK EAST Suite 750	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,655 sq. ft.Note: Building application has been generated under 18016-20000-03193	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10990	16041-10000-21718	200 WORLD WAY TEMP	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Closed	09/29/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	TEMP PERMIT FOR RECONNECTION OF DISTRIBUTION DOA-DCA DURING CONSTRUCTION PHASE. LOAD PROVIDED. DISTRIBUTION TO BE DEMO AT END OF CONSTRUCTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10991	19041-10000-44480	5244 N TUJUNGA AVE	91601	2	171B173   428	2350017013	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.16616	-118.37882	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10992	14041-10000-17094	1 S LMU DR UNIV HALL	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	33.96577	-118.42406	luminaires in rooms  #2100;#1300, and #2600 are retrofited ;new ceiling in place; new ceilingplan chk 9s for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10993	14041-10000-35122	1350 N DEVLIN DR	90069	4	147B169   979	5560037011	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.095	-118.38579	PV1 roof mounted with system size: 6kW with 3 strings total modules: (32)  with (1) inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10994	13041-20000-13659	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	ADDRESS	34.18088	-118.48309	NEW MOTOR STARTERS. HIGH VOLTAGE RELAYS. PLAN CHECK FOR POWER. PER SUPERVISER PC APPROVED. OVER 600V PANEL SECTIONS. SCREW PUMPS STARTER. RECONNECT MOTORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10995	17041-10002-00690	5860 W JEFFERSON BLVD	90016	10	120B173  1729	4205027022	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM			PC Approved	01/14/2019 12:00:00 AM	ADDRESS	34.02504	-118.37633	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 4 & 5 (BULLETIN 01).  CHANGES INCLUDE REMOVING RECEPTACLES/CIRCUITS FROM OUTDOOR PATIO AND REVISING PANEL SCHEDULES. NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-00690	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
10996	17041-20001-37540	8612 N RIVENDELL CT	91306		192B113    94	2782011036							Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.22614	-118.57017	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.4.76kW ungrounded system. (17) EnPhase IQ6 microinverters.(17) 360W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10997	14041-10000-05804	1302 W 177TH ST BLDG B	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	INSTALLATION OF A FIREALARM FOR A NEW THREE STORY 33-UNIT APARTMENT BUILDING (BUILDING A).  1 PANEL AND 91 DEVICES.2 OF 6ELECTRICAL P# 13041-10000-06846.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10998	12041-20000-15933	11560 W TENNESSEE AVE	90064	11	123B153   336	4260024001		West Los Angeles			YES	2677.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	PIN	34.03401687	-118.4436131	Install photovoltaic system on roof of commerical building.  Connect to new 225 ampere rated service to be separately permitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
10999	14041-10000-12048	210 W 7TH ST #1	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			Corrections Issued	05/06/2014 12:00:00 AM	ADDRESS	34.04461	-118.25275	T24 FOR SIGN INSTALLING FOR CVS PHARMACY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11000	17041-20000-09086	13237 N GLADSTONE AVE	91342	7	225B157   672	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Issued	07/06/2017 12:00:00 AM	ADDRESS	34.31154	-118.42954	Plan check for power only. New 2000A service 'MSC' for 99 Cent Store. Refeed existing unit panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11001	13041-10000-22692	1017 N LAS PALMAS AVE FLOOR 1-FLOOR 3	90038	4	144B185   896	5532026036	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.08943	-118.33642	TITLE 24 PLAN CHECK ONLY. EMERGENCY LIGHTING . 2160 SQFT. 3 STORIES. WORK ON ALL 3 FLOOR. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11002	14041-10000-24941	5501 N WILLIS AVE	91411	4	174B149  1087	2249027015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.17046	-118.45546	PV1, INSTALL 5.355 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(21) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11003	17041-10000-25667	13201 N GLADSTONE AVE	91342	7	225B157   700	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.31047	-118.42825	TITLE 24 PLAN CHECK TO REPLACE EXISTING (13) FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA = 37920 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11004	15041-10000-24927	5121 N SAN FERNANDO ROAD WEST bldg 33	90039	13	165B205   119	5593011043	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.1457	-118.27194	FIRE ALARM SYSTEM REPLACEMENT. Hazardous location. Buildings 24 (H-3), 25 (mixed - H-2, H-3, F-2, B), 33 (F), and 34 (H-2, F, B).This permit covers building 33. Fees are under inspection. (4 of 4). See ��150411000018030 for main plan check application.	N	N	Express Permit	06/10/2024 12:00:00 AM
11005	14041-20000-35207	707 W WILSHIRE BLVD 46TH FLOOR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.04893	-118.2572	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. NO CHANGE IN OCCUPANCY.  NEWLY CONNECTED LOAD < 400 AMPS. 16600 SQFT. 46TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11006	19041-20000-21992	7432 W MULHOLLAND DR	90046	4	156B177   525	5570006014	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.12223	-118.35856	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM CONSISTING OF A 13.5 KWH TESLA POWERWALL AND A NEW 125A PANEL TO EXISTING SFD WITH EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11007	18041-10000-39525	2024 E 103RD ST	90002	15	091-5A215 157	6066006055	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	33.94302	-118.23603	NEW ROOF MOUNTED 3.3KW PV SYSTEM WITH 12 PV PANELS ON A SINGLE FAMILY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11008	14041-10000-04290	3607 S TROUSDALE PKWY	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.02013	-118.28566	Plan check for power and energy. First time tenant.(USC university)Total area 11902 SQ FT. One New panel.{{{TENANT IMPROVEMENT PROJECT AT USC SKS 4TH FLOOR; EXISTING BUILDING IS TYPE I, FULLY SPRINKLERED CONSTRUCTED IN 2007; NEW WALLS WILL BE FRAMED WITH METAL STUDS; RENOVATED SPACE CONSISTS OS CLASSROOMS, CONFERENCE ROOMS <SEE COMMENTS>}}}Building permit app # 14016-10000-02828	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11009	12041-10000-03009	8302 W MELROSE AVE	90069	5	141B173   486	5528015074	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM			Corrections Issued	02/09/2012 12:00:00 AM	ADDRESS	34.08345	-118.37044	T.I. for an existing retail space.  New circuits and panels and lighting.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit is on application 12041-90000-02975.  (No suite number, per applicant)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11010	14041-20000-11770	1000 S HOPE ST	90015	15	127-5A207 343	5139008***	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.04346	-118.2617	Title 24. lighting for commercial only at first floor unit 102 and 103 for vanilla shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11011	11041-10000-03315	6233 W HOLLYWOOD BLVD 1ST Flr	90028	13	148-5A189 108	5546030001	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.10179	-118.32556	T.I.  CREATING NEW BATHROOM IN THE  OLD TICKET TRON SPACE AT THE PANTAGES THEATER, ON THE FIRST FLOOR.  HISTORICAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11012	12041-10000-23086	19805 W SANTA RITA ST	91364	3	171B117    38	2164010032	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.16867	-118.56381	New 10.56 kw roof mounted PV system for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11013	19041-20000-09565	4758 W BONVUE AVE	90027	4	153B197   302	5588017008	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.11445	-118.29464	INSTALLATION OF A 10.56KW DC/8.98KW AC CEC/10KW AC ROOFTOP PV SYSTEM. SCOPE OF WORK INCLUDES (32) PANASONIC 330W PV MODULES WITH P400 OPTIMIZERS, AND A SOLAREDGE 10KW HD WAVE INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11014	15041-10000-07007	9448 N TOPANGA CANYON BLVD	91311	12	198B101    79	2746013020	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Closed	01/18/2017 12:00:00 AM	ADDRESS	34.24211	-118.60602	PC FOR POWER AND ENERGY. FIRST FLOOR WITH MEZANINE. CHANGE OF OFFICE TO  RETAIL STORE. DISTRIBUTED POWER WITH 2 PANELS, 6 SUBPANELS AND 2 TRANSFORMERS. TOTAL AREA 15933 SQ FT.B# 14016-20000-26017	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11015	15041-20003-18966	3733 S MOTOR AVE	90034	5	120B165  1312	4314003036	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM			Corrections Issued	03/04/2016 12:00:00 AM	ADDRESS	34.02181	-118.40526	03/04/2016 Plan check for a lost set of plans. PV system has remained the same; PV performance meter has been relocated. *****Previous Work Description*****Changes to approved set.  Reducing transformer from 45 kVA to 30 kVA.  Reducing wire size on AC size from #1 AWG to #6 AWG.****** Plan check for a PV2 roof-mounted PV system. System size is 18 kWac and consists of (2) inverters, (100) modules, (100) power optimizers, (1) load center, and (2) combiner boxes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11016	12041-10000-02522	700 W WORLD WAY Term 7-Spc 7E	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	03/14/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	T.I. to an existing retail space.  CHange to lighting, new circuits and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Terminal 7 - Space 7E	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11017	16041-10000-33292	6801 W HOLLYWOOD BLVD #A3-322	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.10229	-118.33907	TITLE 24 FOR A (TI) CHANGE OF USE TO A RESTAURANT (NON-HIGHRISE BUILDING).TOTAL SQ. FT. 530	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11018	19041-20000-32182	19301 W MERRIDY ST	91324	12	204B117   564	2726019011	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.25194	-118.55402	Plan check for PV roof mounted PV system, PV system size: 10.23KW DC, 9.36KW AC CEC with 31 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11019	19041-10000-13599	8122 N COZYCROFT AVE	91306	3	189B109   116	2108002004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.21756	-118.58166	(ePlan)  LADWP Community Solar Program: 1.96kw AC - 7 solar modules and 7 enphase S280 microinverters. 1 circuit. 1 service interconnected with a meter adapter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11020	16041-20000-33294	23936 W SCHOENBORN ST	91304	12	192B089   143	2017037011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.22084	-118.64838	Plan check for installation of a roof-mounted pv system for a SFD.  Interconnect with a 400A MSP. 3kW ungrounded system. (12) 265W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11021	14041-10000-34732	8556 S EMERSON AVE UNIT 12	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	01/30/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 12 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11022	19041-20000-18284	4915 W LOS FELIZ BLVD	90027	4	150B197   103	5588009007	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.11049	-118.2963	PV1 Plan check for new PV roof mounted system on existing sfd, PV system size: 15.2kW AC, 15.9KW DC with 49 Q cell PV Modules and 2 inverters(7.6kW) connected to existing 400A Service panel and a new 100A solar subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11023	13041-20000-23496	11175 W SANTA MONICA BLVD 9th Floor	90025	5	129B149   297	4324035029	M1-2	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	08/28/2013 12:00:00 AM	ADDRESS	34.04739	-118.44609	T24 FOR EXISTING OFFICE SPACE PART OF A HIGHRISE. RECONNECTING EMERGENCY LIGHTS TO EXISTING CIRCUITS. TOTAL SQRFT 7544. SCOPE OF WORK ON ENTIRE 9TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11024	13041-10000-32778	6100 N TOPANGA CANYON BLVD	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.18131	-118.60555	PLAN CHECK FOR POWER AND ENERGY FOR A 4 STORY OPEN PARKING STRUCTURE. WESTFIELD MALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11025	14041-10000-03218	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.14947	-118.43885	Installation of lighting and receptacles for Starbucks kiosk in a Ralphs supermarket.  Title 24 plan check for lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11026	18041-10000-14403	345 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	34.05424	-118.25562	Plan check for T24 only, TI on existing school kitchen. Total area under the scope: 682 sq.ft with new lighting and circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11027	14041-10000-29094	10007 N SHARP AVE	91331	6	204B157  1188	2645006048	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Expired	11/14/2016 12:00:00 AM	ADDRESS	34.25194	-118.43092	PV1.  Install 6 kW roof-moutned, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11028	18041-10000-06932	18050 W CHATSWORTH ST	91344	12	207B125   637	2731008023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.26455	-118.52561	"Full plan check for first time retail tenant ""Ross"", install new panels, new lighting and power receptacles. Total area: 22,923 sq.ft, T24 form using performance method. B# 18016-10000-05853"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11029	14041-10002-24563	950 S FAIRFAX AVE	90036	4	132B177   328	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	03/03/2018 12:00:00 AM	ADDRESS	34.05875	-118.3633	Changes to approved set.  addition of 9 new methane gas sensors in lobby area.  Battery size increased.*****INSTALLATION OF NEW METHANE MITIGATION SYSTEM.  43 DEVICES , 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11030	16041-20000-17805	9301 N OAKDALE AVE #205	91311	12	198B113   113	2761040019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.23936	-118.56702	Plan check for Title 24 only in existing space T.I. Total area: 2985 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11031	18041-20000-48551	1800 N NEW HAMPSHIRE AVE 1st Floor	90027	4	150B197  1122	5589028045	R3-1	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Apartment			12/21/2018 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.10386	-118.29317	Lobby and leasing office remodel of (E) apartment building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11032	18041-20000-15362	1039 N GALLOWAY ST	90272	11	129B129   569	4423013020	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.04841	-118.52148	ADDITION OF (2) TESLA POWERWALLS TO AN EXISTING PV SYSTEM.  PLAN CHECK FOR POWER ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11033	16041-20000-29170	10147 N CASABA AVE	91311	12	204B113   368	2741006004	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.25517	-118.5762	Plan check for PV roof mounted system on SFD. System size: 6.0kW with 17 modules Sunpower SPR-X21-345 and 1 inverter(6.0kW) Solaredge SE6000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11034	19041-20000-34893	3163 N LA SUVIDA DR	90068	4	159B181   324	5579027016	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	10/12/2019 12:00:00 AM	ADDRESS	34.13228	-118.34295	Plan check for PV roof mounted system and Energy storage device, PV system size: 10.4 DC STC, 9.81 DC PTC, 9.56KW AC CEC with 32 PV Moduels and 32 microinverters and 1 Tesla battery 13.2kWh, 1 200A sub panel, combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11035	19041-20001-08811	13963 W POLK ST	91342	7	228B153   537	2504009014	RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2019 12:00:00 AM			PC Approved	04/05/2019 12:00:00 AM	ADDRESS	34.31798	-118.4383	4/5/2019changes to an approved set of plans.  changes to reflect msp field conditions.  this is plan check only.  (((PV1.  Install 14.625 kW DC / 11.4 kW AC roof mounted grid tied PV system.  (45) modules with 11.4 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11036	12041-10000-22854	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	11255 SQ FT  TENANT IMPROVEMENT OF EXISTING COMMERCIAL SPACE WITH A PROPOSED 968 SQ FT PATIO TO BE A NEW RESTAURANT WITH NEW MEP SYSTEMS; SUITES 150, 160, 170	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11037	17041-20001-16465	3315 N VERDUGO ROAD	90065	1	153A215   307	5457022028	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.11215	-118.23612	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv systems, roof-mounted on church building and detached commercial building. Two systems connecting to two separate services (one is single phase, one is three phase).Total system size: 63.3kW ungrounded. (212) 300W pv modules. (51) P600 power optimizers. (110) P300 power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11038	15041-10001-35942	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Issued	04/28/2016 12:00:00 AM	ADDRESS	33.94955	-118.38342	REVISION TO THE APPROVED SET. ADDITON OF 17 SMOKE DETECTOR FOR CHANGE THE LAYOUT OF THE FLOOR AND ADITION OF SOME OFFICES. ALL CHANGES NOTED DELTA C ON PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11039	11041-10000-20669	1410-1418 S ELKGROVE CIR BLDG 15	90291	11	111B149   425	4243001034	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.00138	-118.45818	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11040	16041-10000-31141	13227 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.31115	-118.42909	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW HEALTH CLUB. SCOPE INCLUDES 2 FA PANELS, AND 29 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11041	19041-10000-41810	11601 W WILSHIRE BLVD STE 102	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	11/12/2020 12:00:00 AM		Permit Finaled	01/14/2021 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING IN A BIKE STORAGE FACILITY. SCOPE OF WORK ICLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 1700 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11042	17041-20001-45309	10241 N MASON AVE	91311	12	204B109   515	2741025182	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	PIN	34.25646128	-118.58026748	Revisions to approved plans.  New 600A 480Y/277V 3ph-4w service.  Other SLD changes.  Approval for clouded changes only.  (((Change of use from full service to self service car wash.   New 600A 480Y/277V distribution with existing service.  Plan check for power and energy.  Building permit under 16014-30000-01102)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11043	19041-10000-12410	6201 W HOLLYWOOD BLVD #100	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.1018	-118.32461	"NEW RETAIL STOREFRONT ""FUNKO HOLLYWOOD"" ON THE FIRST FLOOR.NEW PANELS TRANSFORMERS AND LOADS > 400AMP.TOTAL SQR FT: 29,870.   BUILDING PERMIT: 19016-20000-08473"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11044	13041-20000-06495	22912 W ERWIN ST	91367	3	177B097   295	2039014013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.18266	-118.6259	solar system 10.4 kw single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11045	18041-20000-45676	425 W 8TH ST	90014	14	127-5A209  42	5144013028	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Closed	02/08/2024 12:00:00 AM	ADDRESS	34.04499	-118.25637	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a changes of use from dance hall to bar. Total lighting area = 4,694 sq. ft.Note: Building application has been generated under 18016-10000-36330	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11046	13041-20000-08432	17231 W SHERMAN WAY 1st floor-2nd floor	91406	6	183B133     8	2227016044	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			Corrections Issued	04/02/2013 12:00:00 AM	ADDRESS	34.20136	-118.50861	Plan check for energy only. All circuits are existing per applicant. Emergency lighting and exit signs are existing. St. Peter Armenian Church.REPLACE 3 DAMAGED ROOF RAFTERS, LESS THAN 10%;  CHANGE OUT 18 WINDOWS, SAME SIZE AND SAME TYPE;  REROOF SOUTH PORTION OF THE BUILDING AND REPLACE DOOR HARDWARES REINFORCE (E) MECHANICAL SUPPORT ON ROOF TOP FOR (E) SUNDAY SCHOOL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11047	14041-10000-12333	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Tennant improvement for existing building - Title 24 onlyTotal area = 2193 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11048	13041-10002-17091												Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM				two circuits added to supply two motor controller/panels each supplying 2 sump pump motors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11049	13041-20000-29825	5250 N LANKERSHIM BLVD 5TH FLOOR	91601		171B173   367	2350018086							Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.16668	-118.37545	T24 FOR EXISTING HIGHRISE SCHOOL. SCOPE OF WORK ON THE 5TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11050	19041-10000-39972	1515 W 190TH ST 2nd Flr	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	Energy plan check for an office TI located on the  second floor of an office building. Scope includes new lighting and equipment with a total lighting area of 2,761-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11051	14041-20000-18742	19540 W LORNE ST	91335	3	189B117   228	2105004009	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.21667	-118.55957	PV1 STANDARD PLAN, 5KW roof-mounted system with (20) Canadian Solar 250W modules and one Aurora PVI-5000-TL inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11052	15041-10000-16416	11818 W WILSHIRE BLVD UNIT 300-PHASE 4	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.0474	-118.46308	PHASE 4:REMODEL OF THE CURRENT TENANTS IN VIRTO FERTILIZATION (IVF) LAB AND ADJACENT AREA IN MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11053	11041-20000-04067	21200 W OXNARD ST	91367	3	177B105    75	2149002008	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02, 1371.02	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.17905	-118.59389	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T. I. TO MFG OFFICE AREA AND RESTROOM. NEW LIGHTING ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11054	14041-20000-05422	3737 S WATT WAY SUITE 108	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.01921	-118.28872	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON SUITE 108	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11055	14041-10000-23513	1124-1132 S SAN JULIAN ST	90015	14	124-5A211 205	5145025002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.03521	-118.25351	PLANCHECK FOR POWER AND ENERGY FOR BLDG 16.PLANCHECKER TO ADJUST FEES FOR BLDG 16 AND 17.[[[13016-10000-25985 bldg 16]  RENOVATE (E) 3-STORY PRODUCE WHOLESALE BLDG TO REMOVE ALL INTERIOR STRUCTURES, REPLACE WINDOWS/DOORS, BUILD  NEW RAMPS, STAIRS,RESTROOMS, ELEVATOR (EXISTING PIT), LONG TERM BIKE PKG ROOM, NEW ROOFING/INSULATION AND NEW CONCRETE WALLS FOR STAIR AND ELEVATOR SHAFTS.  SEE COMMENT.]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11056	10041-20000-15827	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	34.10191	-118.28217	lighting and some power in office and ups room. P/C is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11057	19041-10000-09386	8240 N BABCOCK AVE	91605	2	192B161   169	2308004014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Issued	03/15/2019 12:00:00 AM	ADDRESS	34.22111	-118.40698	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 23 MODULES (Q-CELL 305) , 23 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 7.015KWdc and 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11058	14041-20000-27845	3737 S WATT WAY SUITE 108	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.01921	-118.28872	TI to existing commercial office space.  Plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11059	13041-10000-27919	735 S FIGUEROA ST space #202	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Issued	02/25/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	TITLE-24 ONLY PLAN CHECK FOR A RETAIL SPACE. SCOPE OF WORK IS < 400A. TI TO THIS RETAIL SPACE IS LOCATED IN A HIGH-RISE BUILDING. TOTAL AREA IS 1286. ELECTRICAL PERMIT TO BE PULLED AT THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11060	14041-10000-09973	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM			PC Info Complete	04/28/2014 12:00:00 AM	ADDRESS	33.97902	-118.43558	pv2 commercial rooftop. solar modules to be installed on new canopy. total of 60 modules. using 480V interconnection. interconnect to existing 300A service system size 15 kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11061	11041-10000-02168	5710 S CRENSHAW BLVD	90043	8	108B185   693	5006009008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	08/23/2011 12:00:00 AM	ADDRESS	33.99053	-118.33046	Change of use from mechaic shop to retail.  EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11062	17041-10000-12880	7635 N KRAFT AVE	91605	6	186B169   128	2316009032	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.20951	-118.38028	Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 6 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11063	19041-20000-15895	20811 W SIENNA LANE	91326	12	216B109    64	2701078010	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.28754	-118.5863	Plan check for PV roof mounted system, PV system size: 14.04kW DC with 39 PV Modules and 39 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11064	14041-20000-06050	21600 W OXNARD ST SUITE 1755	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.179	-118.6002	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 1755	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11065	19041-10000-27391	6502 N VAN NUYS BLVD	91401	6	180B149   597	2237014006	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			Corrections Issued	08/13/2019 12:00:00 AM	ADDRESS	34.18884	-118.44845	PV2. NEW ROOFTOP COMMERCIAL SOLAR SYSTEM CONSIST OF 168 MODULES (TRINA SOLAR 360), 2 CENTRAL INVERTERS ( SUNNY TRIPOWER 30KW EACH) AND ONE 75KVA TRANSFORMER. SYSTEM SIZE IS 60.48KWdc AND 60KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11066	11041-10000-02132	3620 S MCCLINTOCK AVE	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	09/10/2012 12:00:00 AM	ADDRESS	34.0213	-118.28935	TWO STORY ADDITION PLUS PARTIAL BASEMENT ADDITION TO THE SEELEY G. MUDD BUILDING AND DANA & DAVID DORNSIFE COGNITIVE NEUROSCIENCES IMAGING CENTER; ADDITION INCLUDES OFFICES AND A 100 SEAT AUDITORIUM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11067	11041-10001-00980	9601 S AVIATION BLVD	90045	11	093B173   308	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM			PC Info Complete	05/25/2012 12:00:00 AM	ADDRESS	33.94983	-118.37793	NEW COMPRESSED NATURAL GAS (CNG) FUELING STATION.((((((( per inspector rquest, addition of new feeder on 300 kva xfmr, and show future PV system connection to the existing service, also show sinage..))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11068	16041-10000-45286	970 W 190TH ST SUITE 290	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	33.85812	-118.29302	PC FOR TITLE 24 ENERGY ONLY IN A HIGH RISE BUILDING  SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES.TOTAL AFFECTED AREA OF 1639 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11069	17041-10002-14296	3820 E UNION PACIFIC AVE	90023	14	117A229     8	5192001001	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.01638	-118.19256	**applicant request the same plan check as the original submittal **2nd changes to approved plan, all changes are clouded and noted as Delta-1. Adding (4) panelboards, (2) transformers, adding unit substation, adding new loads > 400A, resizing circuit breakers due to load adjustments, relocating few circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11070	10041-10000-25726	8500 W BEVERLY BLVD # 684	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			Corrections Issued	12/28/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI  REMODEL  OF  (E) RETAIL SPACE (~ 5266 S.F. )@ BEV CENTER; INCL  DOORS, CEILING, PARTITIONS, SHELVING, NEW STORE FRONTPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11071	17041-10001-10505	2697-2701 W JAMES M. WOOD BLVD	90006	1	132A201   169	5077025015	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			02/06/2019 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.05606	-118.28673	"DELTA ""1"" chqnges to approved plans ONLY. Changing all residential unit feeder from copper to alluminum using ROMEX cable. All calculation is being updated on single line diagram.(((PC FOR POWER AND ENERGY FOR A new 4 story 33 units apartment over 2 level sub parking.SERVICE SIZE 1200A 3 PHASE 208/120V TOTAL AFFECTED AREA OF 30442 SQ.FT.FIRE ALARM VARIANCE WAS FILED WITH THE DEPARTMENT.)))"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11072	16041-20000-38235	10604 W BRADBURY ROAD	90064	5	126B161   701	4318041018	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.03744	-118.4176	PV1.  Install 8.84 kW DC roof mounted grid-tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11073	10041-20000-03443	21555 W OXNARD ST	91367	3	177B105    33	2146005177	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM			PC Approved	02/26/2010 12:00:00 AM	ADDRESS	34.17943	-118.59939	"Delta B field revisions (""AS BUILD "" ) to 09041-20000-23345"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11074	10041-20000-19535	8221 W MARMONT LANE	90069	5	147B173   195	5555030010	R4-1D	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	Commercial			10/01/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.0981	-118.36829	T.I. to existing kitchen space.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11075	15041-20001-21894	12813 W FRIAR ST	91606	2	180B161  1197	2332002003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	34.18571	-118.41225	10-02-2015 Change to approved set of plans. Changes include AIC ratting of the panel, disconnect and performance meter from 22kAIC to 10kAIC. Plan check for PV roof mounted system. System size: 11kW with 44 modules and 3 inverters (3.0kW, 3.0kW and 5.0kW). Load calc attatch	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11076	13041-10000-01723	3622 E TACOMA AVE	90065	1	147A219    23	5454012044	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.09906	-118.2252	PV1 PLAN CHECK 2.625KW DC ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING POWER ONE TRANSFORMERLESS INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11077	19041-10000-38947	15303 W VENTURA BLVD 100	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	TI IN AN EXISTING FINANCIAL/ BANKING CENTER. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY. AREA: 1655 SQR FT.BUILDING PERMIT: 19016-10000-15782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11078	14041-10000-08148	12411 W FIELDING CIR BLOCK 7	90094	11	105B161  1220	4211034054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/26/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Closed	09/27/2016 12:00:00 AM	ADDRESS	33.97968	-118.40871	FA FOR APT. playa vista II - block 7. 5 buildings and 2 FACP. Permit to be split into 5 different applications per building? Plan checker to verify fee arrangment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11079	11041-10000-23364	139-147 S LA BREA AVE bldge1-bldg2	90036	5	138B181  1040	5513019009	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM			PC Approved	11/01/2011 12:00:00 AM	ADDRESS	34.0724	-118.34423	core /shell improvements in empty commercial spacesplan chk is for Title 24( indoor and outdoor) only; tenant improvement will follownote that permits for the shell/core work will be on the individual address for each space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11080	19041-30000-47668	5521 W VENICE BLVD	90019	10	126B177   259	5069027008	C2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.04419	-118.35923	PLAN CHECK FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS A NEW FIRE ALARM PANEL WITH 23 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11081	18041-10000-41092	11600 N ELDRIDGE AVE LOT 8	91342	7	213B169  1017	2530001018	(T)RU-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Closed	11/21/2018 12:00:00 AM	ADDRESS	34.28073	-118.38369	PLAN CHECK FOR TITLE 24 FOR OFFICE TI. TOTAL EFECTED AREA APPROXIMATLY 400SQFTSCOPE INCLUDES NEW CIRCUITS AND LIGHTS. BUILDING PERMIT # 18020-20000-00895	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11082	15041-10000-42631	355 S GRAND AVE 31ST	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.05191	-118.2525	ALTERATIONS IN COORIDOR ON THE 31st  FL  OFFICESPLAN CHK IS FOR TITEL 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11083	08041-10004-25417	3566 E 3RD PL	90063	14	123A229    13	5179014032	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM			PC Approved	08/31/2010 12:00:00 AM	ADDRESS	34.03293	-118.19256	Changes to approved plans. New restaurant.  Indoor and outdoor T-24 and emregnecy lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11084	10041-10000-00581	10250 W CONSTELLATION BLVD	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	01/14/2010 12:00:00 AM		Permit Finaled	03/17/2010 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check power and energy for new installtion of lighing in outdoor area. In methane zone level V.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11085	10041-10000-04223	725 S FIGUEROA ST 7TH& 8TH-FLOORS	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.04886	-118.26071	TENANT IMPROVEMENT IN THE REST ROOMS ON THE 7TH  & 8TH FLOORSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11086	14041-10000-16663	6411 W IMPERIAL HWY	90045	11	087B165    12	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	33.93238	-118.3989	NEW 1000 AMP SERVICE AND NEW HANGAR WITH NEW OFFICE FOR LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11087	18041-20000-44319	3717 N LONGRIDGE AVE	91423	4	162B161   646	2385008001	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.13829	-118.41838	PV1.  Install 23.04 kW DC, 20.958kW AC grid tied roof mounted PV system.  (64)  PV modules with 46 microinverters.Fees $11.65 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11088	16041-10000-13146	901 S GRAMERCY DR 1-21	90019	4	132B193   877	5092023013	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.05556	-118.31236	Full Plan check to a new 4 story multifamily resdidential building (21 units). 7 Typical units.  New 1200 A service 120/240V 3 phase 4W. Total sqft = 17,345	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11089	16041-20000-00577	147 E 98TH ST	90003	8	093A205   328	6052003022	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	33.9475	-118.27215	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system. Using 300W power optimizers.(15) 275W pv modules, one optimizer per module.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11090	19041-10003-09937	2600 S HOOVER ST BLD. B, C,-D	90007	9	123A201   122	5123001900	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			10/31/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.03132	-118.2838	PLAN CHECK ONLY. Building B, C, D (10/31/19): CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATIONS OF LOADS (INCREASE IN LOADS) WITH RELOCATION OF SERVICE. MODIFICATIONS TO LIGHTING SYSTEMS AND MODIFICATIONS OF LOADS. ALL CHANGES HAVE BEEN CLOUDED UNDER DELTA C01 (SERVICE ALTERATIONS) AND AS1 10 (LIGHTING SYSTEMS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11091	18041-10000-48971	6462 N LAUREL CANYON BLVD	91606	2	180B165   588	2322007049	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Issued	12/28/2018 12:00:00 AM	ADDRESS	34.18791	-118.39631	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11092	18041-10000-34833	750 S GARLAND AVE	90017	1	130-5A207 275	5143006014	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.05029	-118.26708	Title 24 only- TOTAL AFFECTED AREA = 6457 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11093	13041-10000-17362	729 W 28TH ST	90007	9	121-5A203  48	5123016402	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.02755	-118.28038	PLAN CHECK FOR EXISTING TYPE R2 OCCUPANCY (RESIDENTIAL ) 2- STORY USC SORORITY CHAPTER HOUSE RENOVATION. NEW 800A SERVICE. SITE LOCATED IN METHANE ZONE. MODIFICATION TO SEPARATE FIRE ALARM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11094	14041-10000-11914	5245 W SANTA MONICA BLVD	90029	13	144B193   695	5537009018	[Q]C2-2D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	07/13/2023 12:00:00 AM	ADDRESS	34.09094	-118.30401	PC power and energy for a new 52 units, residential/commercial building. modification for early start conduit only permit has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11095	19041-10000-31072	14715 W BLYTHE ST #1-26	91402	6	189B149   365	2210020017	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	04/10/2022 12:00:00 AM		Issued	04/10/2022 12:00:00 AM	ADDRESS	34.21531	-118.45356	FULL PC FOR A NEW 1000A SERVICE (120/208 3P,4W) THAT FEEDS AN 800A MULTIMETER SWITCHBOARD WHICH SUBFEEDS 26 SUBPANELS. THE NEW SERVICE ALSO FEEDS 350A HOUSE DISTRIBUTION BOARD. TOTAL AFFECTED AREA IS 15,572 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11096	19041-20000-10326	20730 W BEECH CIR #303	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.29311	-118.58554	INSTALLATION OF A 3.02KW DC/2.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (9) SUNPOWER 335 BLK PV MODULES WITH INTEGRATED MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11097	18041-10000-33320	15834 W MOORPARK ST	91436	5	168B141   567	2261011016	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.15661	-118.47835	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11098	18041-20000-07677	12303 W MONTAGUE ST	91331	7	204B165   175	2537005018	M2-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.2551	-118.40128	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the replacement of existing fixtures with LED fixtures. Total lighting area = 39,900 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11099	18041-10000-26937	5540 W 104TH ST	90045	11	090B173   316	4129034002	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	33.94182	-118.37752	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11100	18041-20000-00853	20332 W VIA BOTTICELLI	91326	12	219B113   257	2701059049	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.29746	-118.57668	pv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11101	19041-10000-15793	1429 S LOS ANGELES ST A	90015	14	124-5A207 319	5133012011	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Issued	04/30/2019 12:00:00 AM	ADDRESS	34.0341	-118.26102	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. UNIT A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11102	14041-20000-15204	941 W 37TH PL	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM			PC Info Complete	06/10/2014 12:00:00 AM	ADDRESS	34.01943	-118.2897	Plan check for energy only. USC Salvatori Computer Science Center, renovation on floors 1-3. New lighting, new fan coils, new panels, new emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11103	14041-20000-17857	3664 S BOISE AVE	90066	11	114B153  1162	4246012015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.00561	-118.43863	PV1Install roof-mounted solar array on SFD. System size: 4.08kW(17) EnPhase M250 micro inverters(17) Sun Edison SE-F270CyC pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11104	17041-20000-06194	"7200 W FOOTHILL BLVD Bldg ""C"""	91042	7	202-5A199 563	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.24842	-118.28878	TI and change of use from retail to adult education class room.  Emergency egress lighting existing to remain per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11105	11041-20000-07215	186 S ALVARADO ST	90057	13	135A205   160	5154007004	C2-1	Central	Westlake		YES	2084.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.06425	-118.27166	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11106	11041-10001-25014	601 W 5TH ST	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Approved	02/03/2012 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Delta D revision to approved plans. Revision consist of changing light fixture types and calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11107	14041-10009-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	"PC FOR CHANGES TO APPROVED SET TO REFLECT ""AS BUILD"" CONDITINOS UNDER DELTA 29.PLAN CHECK ONLY!!SCOPE COVERS CHAGES TO ""MMJK"" SWITCH BOARD AND INCLUDE REMOVAL OF TENATS AND RECALCULATION OF LOADING ON THE SWITCH BOARD IN PREPARATION FOR NEW TENANT ""VIP LOUNGE""(TEMP POWER FOR NORDSTROM UNDER DIFFERENT PERMIT) NOTE: Modification of building ordinance has been filed for addition of loads to an existing installation that is not in immediate compliance with section 220.87.  7 day meter readings have been submitted at initial time of plan approval.  30 day meter readings shall be provided for plan check approval prior to finalizing of the project."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11108	18041-20000-45252	18343 W ALGIERS ST	91326	12	213B125   584	2870012029	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.27713	-118.5342	Plan check for a PV1 roof-mounted PV system. System size is 9.57 kWdc/9 kWac and consists of (1) inverter and (33) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11109	15041-10000-27484	9030 W NATIONAL BLVD	90034	5	123B169  1166	4311029014	C2-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.03112	-118.39185	PC for energy only, T-24. Remove HID light fixtures and replace with LED fixtures for a commercial bldg. Sq Ft = 3655	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11110	11041-10000-18477	7617 W SUNSET BLVD	90027	4	147B177   942	5550006028	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	PIN	34.09835673	-118.35560071	REMODEL EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11111	10041-10000-08990	5905 W WILSHIRE BLVD	90036	4	135B177   424	5508016901	PF-1D	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	10/05/2010 12:00:00 AM	ADDRESS	34.06282	-118.35793	NEW TICKET KIOSK PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11112	16041-10000-33917	2226 N STRADELLA ROAD	90077	5	153B145   176	4377029005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.11332	-118.46236	$0 permit fe due to sentae bill 1222 from 2012PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTA SYSTEM SIZE IS 56.24KWdc / 43.2KWac.(163)SUNPOWER SPR-X21-345(163)SOLAREDGE P400(3)INVERTERS-SOLAREDGE SE-14.4KUS(1)SUBPANEL 200A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11113	15041-20001-39355	15651 W SHERMAN WAY	91406	6	183B141    72	2206038012	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.20139	-118.4744	[5/13/16 CHANGES TO APPROVED SET.  PLANCHECK ONLY. UPDATE SET TO MATCH INSTALLATION PER INSPECTORS REQUEST]]]Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,020 sq. ft.Note: Building application has been submitted under 15016-20000-25741.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11114	14041-20000-21811	933 S MASSELIN AVE	90036	4	132B177   602	5089017037	R1-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.05829	-118.35451	Standard plan: 5.5KW PV1 roof-mounted system including (22) EnphaseM215 microinverters and Trina Solar TSM-250P modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11115	16041-10000-27248	5510 S LINCOLN BLVD STE 150	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	33.97299	-118.43051	Tenant improvement. PC for title 24 to a commercial office building. Installing new lighting and power only. Total sqft = 3180.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11116	19041-10000-10400	529 S CERES AVE	90013	14	126A215    56	5147017022	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.04085	-118.24064	TI in an existing commercial area. Installing Light and (2) panels. T-24 Energy Only.Area: 5,185 Sqr Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11117	10041-10002-22348	8378 W MELROSE AVE	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM			PC Approved	10/06/2011 12:00:00 AM	ADDRESS	34.08341	-118.37285	"Modification to approved plans to reflect field conditions. <<<<<TI in a retail. New service and panels. EPC for power and energy. CORE & SHELL ONLY.  COMPLETE PLAN CHECK WILL BE REQUIRED FOR EACH TENANT.  <<<<<<Methaen Buffer Zone Level 1 with less than 2"">>>>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11118	16041-20000-45283	122 N LARCHMONT BLVD	90004	4	138B189   882	5515024003	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.07368	-118.32343	ti to an existing commercial building single story.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 607.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11119	15041-10000-30609	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.20696	-118.3417	title 24, Relocating guardhouse. installing new lighting, controls to new equipment. Newly connected load less than 400 amps, pc for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11120	16041-10000-16012	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			05/13/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	PIN	34.04222127	-118.45848597	NEW MIXED USED APARTMENT BUILDING 147 UNIT 5 STORIE .PLAN CHECK FOR POWER AND ENERGY. 12 TYPICAL UNITS, 6 LOFTS AND 3 LIVEWORK UNITS. WITH TOTAL AREA OF 1927884 SQFT. NOTE FIRE ALARM VARIANCE IS FILLED TOGETHER. BUILDING APPLICATION NUMBER 14041-10000-03747.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11121	19041-10000-03116	1338 W 221ST ST	90501	15	048B193   429	7346015005	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	33.82667	-118.30089	Plan check for a PV1 6kw AC / 6.72 KW DC roofmounted system with (21) modules and (1) invterter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11122	17041-10002-37851	1129 N MONUMENT ST	90272	11	129B125   390	4423001039	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			PC Approved	08/15/2018 12:00:00 AM	ADDRESS	34.0497	-118.52498	PC ONLY FOR LOST SET OF PLANS. SCOPE INCLUDES PV SYSTEM AND 2 TESLA STORAGE SYSTEMS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11123	11041-10001-03174	535 N LARCHMONT BLVD	90004	4	141B189   979	5523016026	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/04/2011 12:00:00 AM	ADDRESS	34.08003	-118.3239	Change the approved plan. EPC is for the changes on Fixture scheduel, & T24. (((((((((T.I.  2 NEW 200 AMP PANELS.  TITLE 24 ONLY.   2 STORY COMMERCIAL BUILDING.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11124	19041-20000-11875	6809 W LEXINGTON AVE	90038	4	144B185   387	5532006040	C2-1D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	08/14/2020 12:00:00 AM	ADDRESS	34.09267	-118.33903	TI 24 PLAN CHECK FOR EXISTING BUILDING. INSTALLING NEW LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 9477 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11125	16041-10000-18352	3714 S KELTON AVE 1-16	90034	5	117B161   574	4252025043	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.01774	-118.41287	plan check for new fire alarm system for a 16 unit 3 story apartment building. Includes 1 control panel, 1 FA panel, 2 communication panel, 67 FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11126	16041-20001-04872	5754 N CHICOPEE AVE	91316	5	174B129   275	2254020018	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.17564	-118.51214	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Addition of a 3 kWac system onto an existing 3 kWac for a total system size of 6 kWac. Addition consists of (1) inverter, (8) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11127	14041-20001-05984	13553 W PIERCE ST	91331	7	204B157   498	2646010014	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.25662	-118.42803	Fee for Expedite only.*****Roof mounted PV system with tranformerless, system size is 5.8KWdc.*****Note: Permit includes upgrade service panel to 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11128	19041-10000-51564	19747 W GREENBRIAR DR	91356	3	165B117   389	2178005059	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	34.14591	-118.56311	PV PLAN CONSISTING OF 197 (TESLA #SR60TI) MODULES, 3 CENTAL INVERTERS ( DELTA SOLIVIA), CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS  11.15 KW DC &14.2KW AC.PERMIT FEE IS $ 0 ACCORDING TO AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11129	10041-20001-21033	19503 S NORMANDIE AVE	90501	15	060B193   443	7351002030	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM			PC Info Complete	05/26/2011 12:00:00 AM	ADDRESS	33.85617	-118.3012	Changes from previously approved plans.  Changes include lighting and branch circuits.  All changes are indicate by delta and clouded on plans.  Plan check for power and energy.Note:  The approved plans submitted for reference only.*****Plan check for T24 Energy indoor, outdoor, and emergency lighting for general remodel of Walmart. New load does not exceed 400A.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11130	14041-10000-25692	12534 W FIELDING CIR	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	33.97822	-118.412	PLAN CHECK FOR FIRE ALARM SYSTEM FOR APARTMENT COMPLEX WITH MULTIPLE BUILDING WITH MULTIPLE ADDRESSES. THIS IS BUILDING 4 OF 7. ALL BUILDING UNDER ONE SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11131	17041-10000-33207	2001 E 103RD ST	90002	15	091-5A215 121	6046021001	A1(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	33.94325	-118.23651	Plan check for power and energy of new Community Education Center, Barn, Mastergardener Center. Total area: 44,220. Application 2 of 3 This permit covers panels CP and Cl in classroom building.Note: 3 Buildings supply by 1 Service(800A). There are 3 electrical application with 1 plan. Building application number: 17010-10000-02862	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11132	15041-10002-23151	1550 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.09932	-118.32644	01/18/2017 Changes to an approved set of plan. Changes include recalculating Title 24 for screw shell sucket per title 24. Changes has been clouded as delta 10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11133	12041-20001-29398	1006 N SEWARD ST	90038	4	144B185   938	5533012025	[Q]MR1-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Info Complete	08/08/2013 12:00:00 AM	ADDRESS	34.08914	-118.33305	Changes to approved set of plans. Plan check for energy and power. New restaurant in remodeled building.  Located in Methane Buffer Zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11134	16041-10000-36085	3944 S INGLEWOOD BLVD	90066	11	111B157   150	4214021026	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.00349	-118.42653	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 4385 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11135	10041-30000-11092	10250 W SANTA MONICA BLVD #134	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Lighitng and power in retail store. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11136	15041-10000-39356	625 N NORMANDIE AVE	90004	13	141B193   760	5520002047	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.08247	-118.30076	FA, (1) Fire alarm panel. (13) Fire alarm devices. 5 unit apartment complex.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11137	10041-20000-10430	16444 W BOSQUE DR	91436	5	165B137   541	2291016025	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2010 12:00:00 AM			Plans on Hold	06/04/2010 12:00:00 AM	ADDRESS	34.14506	-118.49186	Plan check new installation for 11.03KW Photovoltaic System for single-family dwelling.customer requested a refund claim # 104864 on 4/27/12	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11138	12041-20000-25476	12925 W MAGNOLIA BLVD	91423	4	171B161   450	2345017031	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM			PC Approved	10/24/2012 12:00:00 AM	ADDRESS	34.16502	-118.41473	Existing permit 12041-20000-17897, plan check for lighting systems only.  Inspector please verify that the inline circuit breakers are integral to the lighting track.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11139	14041-20001-13777	15523 W LEMAC ST	91406	6	189B145   596	2222004007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.21146	-118.47129	Expedite per customer request13KW PV1 roof-mounted system with (52) Canadian Solar CS6P-250PX modules with optimizers and (2) Solaredge SE6000A-US-ZB-U transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11140	11041-10002-27025	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM			PC Info Complete	02/06/2013 12:00:00 AM	ADDRESS	34.04661	-118.2324	REVISED PLANS TO SHOW THE ADDITIONS OF PANELBOARDS AND CKTS FOR 40AMP GROUNDED AC OUTLETS FOR VEHICLE CHARGING STATIONS TO COMPLY WITH LAGBC 4.106.6.2PROPOSED 6-STORIES MIXED USE BUILDING: RETAIL;APTS;LIVE/WORK UNITS;OFFICES;GARAGE;PORTION OF THE BUILDING IS 5-STORIES, TYPE IIIA, APTS OVER 1-STORY TYPE I GARAGE/RETAIL/OFFICE.OTHER PORTION IS 3-STORIES TYPE IIIA APTS OVER 3-STORIES TYPE I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11141	13041-10000-32364	735 S FIGUEROA ST # 215	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	FIRST TIME TENANT, FULL PLAN CHECK FOR BATH & BODY WORKS. (E) PANEL MDP 277/480V, 3PH, 4W, 400A SUPLY. ADDITION OF (2) 225A PANELS, (1) 75KVA XFORMER. LIGHTING WORK IS FOR 2526 SQ FT AREA USING TAILOR METHOD.FA for variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11142	15041-10001-27660	602 N FICKETT ST	90033	14	129A225    85	5177023024	[Q]C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.04876	-118.2038	PV1 installation of a roof mounted solar system for a residential site connected to 3 meters. (1) distribution panel of 125 amps. (1) inverter 3KW. (9) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11143	13041-10000-35642	947 S TIVERTON AVE 4F,5F,roof	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			12/20/2013 12:00:00 AM			Reviewed by Supervisor	05/01/2014 12:00:00 AM	ADDRESS	34.06246	-118.44303	pc for power and energy. assisted-livingTI EXIST APT UNITS ON ENITRE 4TH AND 5TH FLOORS AND REMOVE AND REPLACE EXTERIOR WINDOWS ON THESE LEVELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11144	17041-20000-02838	4874 N TOPANGA CANYON BLVD	91364	3	168B101   556	2171016076	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	34.15637	-118.60558	Plan check for energy only. TI/Change of use from retail to restaurant (ice cream parlor). New lighting, 718sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11145	14041-10000-35612	120 S GRANVILLE AVE	90049	11	135B145   691	4401002010	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Issued	12/24/2014 12:00:00 AM	ADDRESS	34.06333	-118.47138	New fire alarm system with (121) devices, (2) power supply and (1) fire panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11146	16041-20000-03318	4663 N CAHUENGA BLVD 1-7	91602	4	168B177   742	2421019005	RD2-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1255.02	Electrical	Electrical	Apartment			01/29/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.15569	-118.3618	PLANCHECK FOR POWER AND ENERGY. NEW 7 UNIT, TWO STORY APARTMENT BUILDING OVER ONE LEVEL PARKING GARAGE ON GRADE. FIRE ALARM VARIANCE HAS BEEN SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11147	19041-10000-39085	3208 N HUMBOLDT ST	90031	1	141A221    16	5205006059	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	06/29/2023 12:00:00 AM		Permit Finaled	05/09/2024 12:00:00 AM	ADDRESS	34.08254	-118.21583	PC FOR ENERGY ONLY, SCOPE OF WORK IS A CHANGE OF USE FROM FROM OFFICE WAREHOUSE TO COMMERCIAL KITCHEN.  SCOPE OF WORK INCLUDES NEW LIGTHING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 3136 SFQT. B# 19016-10000-30862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11148	18041-10001-03631	1457 N VAN NESS AVE	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.09731	-118.31598	DELTA 7 CHANGES TO APPROVED PLANS. LIGHTING CHANGES IN 81,391 SQR FT.<<<Plan check for power and energy. Project site is an existing commercial building. Project scope is a first time tenant/tenant improvement. Total lighting area = 79,217 sq. ft.>>>Note: Building application has been generated under 18016-10000-02052	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11149	16041-10002-32756	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	Revision to approved set to add 5 devices due to architectural / floor plan change.<<METHANE MITIGATION FOR 8 STORY MIXED USE. MITIGATION AND METHANE ALARM PLAN PROVIDED>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11150	15041-20000-06572	18970 W BRASILIA DR	91326	12	216B121   364	2872010004	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Expired	05/02/2017 12:00:00 AM	ADDRESS	34.28763	-118.54388	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 11kW (6+5). Ungrounded system. (51) 255W pv modules each with a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11151	12041-10000-31120	1045 S MAPLE AVE	90015	14	126A209   298	5145020048	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM			PC Info Complete	12/28/2012 12:00:00 AM	ADDRESS	34.03743	-118.25519	TI IN AN EXISTING COMMERCIAL SPACE. plan check for title 24. 7924 sq ft.  UNITS 101A, 102A, 103A, 104A, 101B, 102B, 103B & 104B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11152	17041-20002-44710	7517 N CLEON AVE	91352	2	186B173   445	2410001009	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.20713	-118.36827	01/19/2018 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the SLD to show existing distribution equipment. *****Previous Work Description*****Plan check for solar pv system w/roof-mounted array for SFD.3.91kW ungrounded system. (17) EnPhase IQ6 microinverters.(17) 275W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11153	11041-20000-22685	748 E 8TH ST	90021	14	126A211   441	5146024029	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM			PC Approved	10/24/2011 12:00:00 AM	ADDRESS	34.03728	-118.24804	T.I.  Replacing existing light fixtures with new light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11154	17041-10001-25117	5412 W MONROE ST	90038	13	141B193   250	5535013011	R2-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.08565	-118.31181	OFF HOUR PLAN CHECK FEE ORIGINAL PERMIT 17041-10000-25117Plan check for roof mounted PV system - scope includes 3.6KVA system consisting of 1 inverter (ABB 3.6-S-US), and 15 modules (trinamount)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11155	17041-20000-43714	6461 N PENFIELD AVE	91367	3	180B113   685	2134038013	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	03/31/2018 12:00:00 AM	ADDRESS	34.18827	-118.56925	PV1.  Install roof mounted PV system sized 20kW interconneced with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11156	19041-10002-06984	1505 N EDGEMONT ST f0073	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/06/2021 12:00:00 AM	ADDRESS	34.09843	-118.29637	POWER PLAN CHECK TO REPLACE X-RAY EQUIPMENT AT A MEDICAL FACILITY OFFICE RM #F0073 (KAISER). SCOPE ALSO INCLUDE RETROFIT THE EXISTING LIGHTS IN THE BATHROOM AND CONTROOM TO A 90 MINUTE BATTERY BACKUP EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11157	11041-10000-07904	5300 S CENTRAL AVE	90011	9	108B209   358	5104014032	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10, 2291.00	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM	12/27/2011 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	33.99464	-118.25626	New Coin Laundry. New 800 Amp service, distribution board, panel board, and circuits. EPC is for power & Energy.  Electrical plan check determined that although the feeder load  calculations as indicated on the plan are incorrectly done, that the loads as presented do not exceed the rating of the electrical service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11158	17041-10000-02744	6511 W SANTA MONICA BLVD	90038	13	144B185   693	5533010042	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.09088	-118.33135	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURE WITH NEW LED FIXTURES FOR EXTERIOR USE. TOTAL AFFECTED AREA IS 21550 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11159	18041-20000-42897	6407 W MARYLAND DR	90048	5	135B173   453	5510013002	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.06741	-118.36794	PV1.  Install roof mounted grid tied PV system with energy storage system. PV system size: 8.25kW DC, 7.01kW AC with 25 PV Modules and 1 inverter(7.6kW) with 9.8kW LG battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11160	18041-10000-04616	10700 W SANTA MONICA BLVD 130-160	90025	5	129B157   367	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			PC Info Complete	02/16/2018 12:00:00 AM	ADDRESS	34.05167	-118.432	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR WORK ONLY. TOTAL AFFECTED AREA 4387 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11161	13041-10000-30818	13192 N FENTON AVE	91342	7	225B157   793	2512015021	R1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.31014	-118.42108	PV1, Install 7.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Fronius IG Plus V 7.5. 30 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11162	14041-10000-26431	7050 N VALJEAN AVE	91406	6	183B141   248	2224010034	(Q)M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.19905	-118.4857	Title 24 plan check only. Remove HID light fixtures and replace with new flourescent fixtures.Total area = 37020 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11163	12041-20000-26828	9733 N KENTLAND AVE	91311	12	201B097   189	2727003038	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	PIN	34.24722166	-118.61830017	New rooftop photovoltaic system for an existing single family dwelling.  PLAN CHECK IS ONLY FOR PV SYSTEM, NOT FOR DE-RATING THE MAIN BREAKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11164	16041-20000-39989	20770 W NORDHOFF ST	91311	3	198B109   219	2780001060	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.23522	-118.58647	First time tenant for Hitachi light manufacturing and warehouse commercial space.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11165	17041-10003-16328	9029 N DE SOTO AVE	91304	3	195B109    20	2779001035	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.23441	-118.58877	"DELTA ""3"" Changes to approved set by reducing lights and relocating switches.Portion of the permit fee is paid under  #17041-10000-16328 and #17041-10001-16328"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11166	16041-10004-15028	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	12/02/2016 Changes to an approved set of plans. Changes include TI location move within the same level at different location with the same quantity of lighting fixtures and circuits inside IT room. Changes apply to DCN-013 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11167	14041-10000-16111	11620 W WILSHIRE BLVD	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	This is a T.I for 8th floor of a high rise , title 24  and emergency lighting ( existing.) two sources of power to exit signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11168	14041-10000-31563	6851 W IMPERIAL HWY 1200 SQ ft	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Expired	12/15/2017 12:00:00 AM	ADDRESS	33.93207	-118.40981	TI inside warehouse offices. Total 1200 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11169	16041-20001-37290	13340 W VANOWEN ST	91405	2	180B157    51	2329020022	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.1938	-118.42413	Revisions to approved set of plans.  Approval for delta-1 room layout changes only.  (((Plan check for Title 24 only. Project site is a new 3-story apartment building with street level parking. Project scope is commom area lighting. Total lighting area = 2,057 sq. ft.Note: Building application has been generated under 16010-20000-04886)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11170	12041-10000-03080	14651 W VENTURA BLVD	91403	4	166-5A149  38	2265005024	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Public Safety Only			02/09/2012 12:00:00 AM			Ready to Issue	02/14/2012 12:00:00 AM	ADDRESS	34.15174	-118.45268	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11171	19041-10000-15349	1835 N KENMORE AVE	90027	4	150B197  1007	5589033035	RD1.5-1XL	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Apartment			04/25/2019 12:00:00 AM	05/15/2020 12:00:00 AM		Permit Finaled	12/01/2020 12:00:00 AM	ADDRESS	34.10447	-118.29744	REMODELING 12 UNITS APARTMENT BUILDING-UPGRADE SERVICE TO 600A, NEW 100A PANELBOARDS FOR THE APTS, CHANGING LUMINAIRES IN THE APARTMENTS TO LED TYPES, AND NEW OUTDOOR LUMINAIRES. 40 BRANCH CIRCUITS CHARGED UNDER FINAL, REST OF THE PERMIT/INSPECTION FEES HAVE BEEN PAID UNDER 19041-20000-40758.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11172	19041-10000-47656	5808 W SUNSET BLVD 14TH FL	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.09782	-118.31646	PARTIAL TENANT IMPROVEMENTS TO OFFICE SPACE (3838 SQFT) TO CREATE OPEN OFFICE SPACES AND REMOVE ONE OF MEN'S RESTROOMS; WORK TO INCLUDE NON-BEARING PARTITIONS AND FINISHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11173	15041-10000-09058	2510 W TEMPLE ST	90026	13	138A205   190	5157008012	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.07192	-118.27348	INSTALL NEW MEHANE MITIGATION SYSTEM. 11 SENSORS AND ONE CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11174	14041-20000-18518	7315 N FARRALONE AVE	91303	3	186B101   822	2023026027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.2033	-118.61045	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(21) TRINA SOLAR MODULES (1) SOLAR EDGE PVI-5.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11175	18041-20000-18368	20944 W VANOWEN ST	91303	3	180B109    17	2148027005	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			05/23/2018 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	01/03/2024 12:00:00 AM	ADDRESS	34.19351	-118.59014	Plan check for power and energy fo new appartment 38 units and 6 story building. Total area: 336981 sq ft. B#16010-10000-04924Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11176	14041-20000-07271	11911 W SAN VICENTE BLVD suite 200	90049	11	129B145    78	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.05295	-118.47002	TI energy plan check suite 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11177	12041-10001-22864	108 E 5TH ST	90013	14	129A211   204	5148019010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.04636	-118.2484	Modifications to approved set submitted per inspector request.  Additional load to basement panel HG for 2 sump pump circuits, compressor unit, and fan coil.  (((Plan check for power and energy. Add 2-stories to existing 3-story building resulting in a 5-story building.  Remodel and renovation of existing building to new mixed-use of 69-unit affordable housing development with ground floor future retail spaces. New 2000A service. (1600A supplying residential/house + 600A future retail). Modification to seperate fire alarm has been filed.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11178	12041-20002-01857	6600 N TOPANGA CANYON BLVD #1044	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM			PC Approved	04/06/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24 lighting plan check for remodeled store 1044.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11179	11041-20000-26729	2500 N ROSCOMARE ROAD	90077	5	156B145   273	4378023007	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.12245	-118.46321	New 8.64 KW ground mount PV system for single family residence.  Inspector to verify that each string is 12 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11180	19041-20000-34142	5938 N WOODLAND VIEW DR	91367	3	177B085   508	2032026021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.17842	-118.66404	Plan check for PV roof mounted system, PV system size: 7.26KW with 7.26KW DC, 6.47KW AC with 22 PV Modules and 22 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11181	18041-10000-48209	10960 W WILSHIRE BLVD 22nd floor	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.058	-118.44597	T-24 ONLY FOR PARTIAL TENANT IMPROVMENT IN 22ND FLOOR SPACE. 4 OFFCE SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11182	15041-20000-05886	13311 W REMINGTON ST	91331	7	204B157   537	2620018033	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.25644	-118.42289	Plan check for a PV1 roof-mounted PV system. System size is 3.7 kWac and consists of (17) modules, and (17) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11183	12041-10000-13372	1027 S LA BREA AVE	90019	10	132B181   842	5084014027	C2-1	Central	Wilshire	P.I.C.O.		2162.00	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM			PC Approved	06/08/2012 12:00:00 AM	ADDRESS	34.05617	-118.34522	title 24 for retail use single story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11184	14041-10001-34985	6060 W WILSHIRE BLVD	90036	4	135B177   526	5086009014	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Closed	12/28/2015 12:00:00 AM	ADDRESS	34.06273	-118.36103	(((6/10/2015- CHANGES MADE TO APPROVED SET. CIRCUITS RELOCATED, T24 CHANGED, AND SOME SINGLE LINE CHANGES. FEES TO BE REVIED AGAINST APPROVED SET FOR DOUBLE CHARGE)))Plan check for power and title 24.  Renovation to gallery spaces and restrooms in existing museum. New lighting and panels are being installed.  Also 20 panels are being replaced in kind but are denoted as existing on the plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11185	14041-20000-28369	12223 W ADDISON ST	91607	2	171B165  1056	2356013013	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.16136	-118.39947	PV1Microinverter standard plan.Install roof-mounted solar array on SFD. System size: 8.64kW.(36) EnPhase M250 microinverters(36) SolarWorld SW270 Mono Black pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11186	19041-10000-51272	3851 W 6TH ST	90020	10	135B193   859	5503020022	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.06365	-118.30684	Replacing Existing outdoor HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11187	19041-10000-31466	1951 N MANDEVILLE CANYON ROAD	90049	11	138B137   611	4426008009	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	02/09/2022 12:00:00 AM	ADDRESS	34.07042	-118.49608	[EPLAN] PLAN CHECK FOR ROOF MOUTED 13.44KVA PV1 SYSTEM CONSISTING OF 42 AC MODUELS(SPR-X22-360D-AC)MAIN BREAKER DERATING SHALL BE PULLED UNDER DIFFERENT PERMIT. PERMIT FEES ARE $0 DUE AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11188	13041-20000-03135	925 S WESTWOOD BLVD	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.0632	-118.44558	Plan check for energy and emergency lighting. Glissin Tanning Salon. Lighting to be installed on existing panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11189	14041-20000-07444	13630 W WILLARD ST	91402	6	189B157   159	2213019041	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.2175	-118.42943	Install (28) outdoor signages.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11190	10041-10000-08869	4425 S CENTRAL AVE Section C	90011	9	112-5A209 121	5108028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.00306	-118.25677	remodel the interior of a family health center; work is divided into two phases- phase 1 is REVIEWED UNDER 10041-10000-08868 . Phase 2 renovation INCLUDE SUPPORT AREAS AND OFFICES . plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11191	18041-10000-07315	1108 S POINT VIEW ST	90035	5	132B173   908	5087023032	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	03/30/2019 12:00:00 AM	ADDRESS	34.0559	-118.36812	PC for three new tesla powerwalls in SFD. Scope includes powerwalls, disconnects, distribution board. Using fuse let through.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11192	19041-10000-43115	15100 W ERWIN ST	91411	6	177B145   361	2242025901	OS-1XL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	08/21/2020 12:00:00 AM	ADDRESS	34.18281	-118.46212	REPLACING EXISTING FIRE ALARM SYSTEM CONSIST OF 1 NEW FIRE ALARM CONTROL PANEL, 1 NEW COMMUNICATOR AND 56 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11193	12041-10000-16866	979 S SERRANO AVE	90006	10	129B193   143	5080015012	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			07/19/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.05333	-118.30653	New Fire Alarm System for a new apartment building.  6-story, 44 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11194	10041-10000-25838	5670 W WILSHIRE BLVD 23rd fl	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	12/30/2010 12:00:00 AM	ADDRESS	34.06222	-118.35208	tenant improvement of officesplan chk is for title 24 ; permit obtained on 10041-90000-24036	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11195	13041-20002-30932	735 S FIGUEROA ST LEVEL M3-SPACE 303	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	Stock room space redesigned as office, Title 24 plan check only for changes to lighting system in that space independent of rest of store.  (((PC FOR POWER AND ENERGY. NEW H&M RETAIL. WORK DONE IN LEVEL M3. #303. NEW EQUIPMENT RATED >600A. ENERGY USING TAILORED METHOD..  PLANS AND PERMIT ARE TO BE SUBJECT TO 2013 CALIFORNIA ELECTRICAL CODE, PER VARIANCE SUBMITTED.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11196	19041-10001-08444	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.07417	-118.26931	EXPEDITED PER CUSTOMER REQUESTPlan check for a 408KW AC / 452KW DC roofmounted PV2 system, located on the top of a commerical building and (2) carport. Scope includes (1222) modules, (90) strings, (18) inverter interconnectring through the load centers to back feed the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11197	16041-20000-40182	156 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.07461	-118.32343	T.I. to an existing commercial building.  adding new lighitngnew controls to existing panels.  plan check for energy and em lighting only.  total square footage 2200.COMPLY WITH DEPT ORDER EFFECTIVE DATE 12/31/2010 PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11198	17041-10001-09894	680 W KNOX ST #150	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	33.85408	-118.28767	PC FOR ENERGY ONLY. T.I FOR A COMMERCIAL BUILDING. TOTAL AREA 7103 SQ FT. B # 17016-10000-07361	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11199	10041-10000-17601	523 W 6TH ST 5th floor	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	PIN	34.04872199	-118.25441618	Ti in the 5th floor East restroom. Plan check for T24 and emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11200	16041-20000-23387	10728 N NASSAU AVE	91040	7	208-5A193 480	2556005028	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Expired	09/12/2018 12:00:00 AM	ADDRESS	34.26417	-118.31041	Plan check for PV roof mounted systm. System size 7.6kW with 34 modules and 1 inveter(7.6kW) Center feed system .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11201	13041-10000-21770	780 N SWARTHMORE AVE	90272	11	126B125   117	4412009031	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.04464	-118.52629	School cafeteria remodel.  Installation of new panel and 10 new heaters.  Upgrading of lighting.  T24 plan check only for lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11202	19041-10000-47941	1660 W ANAHEIM ST	90731	15	030B197    11	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	06/01/2020 12:00:00 AM		Issued	06/01/2020 12:00:00 AM	ADDRESS	33.77884	-118.29327	POWER PLAN CHECK FOR INSTALLING 2 x NEW 1200A MCC SECTIONS TO EXISTING ELECTRICAL SYSTEM FOR LOS ANGELES REFINERY WILMINGTON. SCOPE INCLUDES NEW MECHANICAL LOADS. HAZARDOUS CLASSIFIED LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11203	16041-10000-24403	1133 S SWALL DR	90035	5	132B169   617	4332011034	R2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Expired	08/20/2018 12:00:00 AM	ADDRESS	34.0562	-118.38582	PV1 roof mounted solar system to a single family home. Installing a central inverter rated 3.0 kw, (14) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11204	12041-10000-05274	8000 W SUNSET BLVD # 2A	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			Not Ready to Issue	09/12/2012 12:00:00 AM	ADDRESS	34.09783	-118.36466	TENANT IMPROVEMENT OF AN EXISTING RESTAURANT (2571 SQ FT WITH A 728 SQ FT PATIO; A2 OCCUP., OCCUPANT LOAD = 65)  New lighting, receptacles, and loads.  PLAN CHECK ONLY for Energy, with Emergency lighting. PERMIT WAS ISSUED UNDER PCIS # 12041-90000-16939 &  12041-10001-16939	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11205	15041-10006-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	11/03/2016 CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REVISED CIRCUITS TO INCLUDED ROOMS ON PANEL SCHEDULE, ADDITION OF NEW BRANCH CIRCUITS, ADDING, REMOVAL OR RELOCATION OF RECEPTACLES ON FLOOR PLAN. CHANGES HAVE BEEN CLOUDED AS (DELTA 38 - ASI-200/200R1) ON PLAN.NOTE : PACKAGE #6.INCLUDED ARE DELTA # 35 CHANGES(APPROVED SET).DELTA # 37 CHANGES SUBMITTED 11/03/2016DELTA # 36 CHANGES ARE STILL IN PLAN CHECK UNDER APPLICATION 15041-10004-14585	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11206	16041-10001-23099	950 S BERENDO ST	90006	10	132B197  1176	5078008023	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Apartment			05/24/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.05416	-118.29358	Supplemental PC for removal of common laundry area in apartment building and installing individual laundry circuit in units. Removing electric range and replacing with gas range. Changes in kitchen receptacles. PC for loading, new panel sizing and feeder sizing.  All changes are clouded under delta 2. Note that dwelling unit numbering scheme has changed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11207	17041-20000-38381	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	Plan check for power and energy. Core and sheel for new 2-story commercial building (ground floor retail/restaurant, second floor storage) on footprint of existing fire damaged building (w/same use, historic).New 1,200A 120/208V 3ph 4w service. Installing new panels/loads and refeeding existing distribution for other tenants. New lighting: indoor - 3,500sqft; outdoor - 535sqft. Project is located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11208	14041-20001-11533	3012 W EFFIE ST	90026	13	144A205   192	5425016006	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/22/2014 12:00:00 AM	ADDRESS	34.08958	-118.26998	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 3kW(1) Solar Edge 3000 transformerless inverter(10) REC260PE pv modules]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11209	18041-20000-37804	9801 N SHOUP AVE	91311	12	201B101   242	2727004013	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.24818	-118.61505	Plan check for a PV1 roof-mounted PV system. System size is 16.380 kWdc/15.4 kWac and consists of (2) inverters, (52) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11210	19041-10000-41143	7300 W SUNSET BLVD	90046	4	147B181   664	5550018024	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	34.09784	-118.34981	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11211	17041-10000-25990	12114 N DARBY AVE	91326	12	219B121   405	2870003003	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2017 12:00:00 AM			Reviewed by Supervisor	08/07/2017 12:00:00 AM	ADDRESS	34.29297	-118.54163	PC FOR ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 10.8 KW ACSCOPE INCLUDE 31 MODULES WITH OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11212	11041-10000-00994	7301 W WORLD WAY WEST 1ST FL	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	TENANT IMPROVEMENTS ON 1ST FLOOR:  NEW RESTROOMS AND SECURITY LOCKER ROOMS FOR MEN AND WOMEN.  1400SFPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11213	16041-20000-24362	11647 N SWINTON AVE	91344	12	213B137   255	2605018028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.28207	-118.48558	PV1.  Installation of 12 kW roof mounted PV system.  (41) modules with (2) 6 kW rated inverters with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11214	17041-10000-25779	5133 N WHITSETT AVE	91607	2	171B165   657	2357006005	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.16415	-118.40542	PLAN CHECK FOR POWER FOR - NEW 3- STORY SINGLE FAMILY DWELLINGS WITH ROOF DECK  PER SMALL  LOT SUBDIVISION  - VTT-74059-SL - 6 UNITS ) SCOPE CONSIST OF NEW 600A SERVICE SUPPLYING 6 INDEPENDED SINGLE FAMILY DWELLINGS. PERMIT FOR THIS JOB IS FOR SERVICE ONLY - REMAINING PERMITS ARE OBTAINED UNDER COMBO PORMITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11215	18041-20001-37694	12632 W SUNSET BLVD	90049	11	132B141   565	4405028017	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.05702	-118.48405	5/16/2019changes to an approved set of plans.  changes to reconfigure interconnection point for pv system and batteries.plan check for power only.   (((Plan check for energy storage system install in to existing PV System, 2 Powerwall 13.5kWh, Energy Storage System size: 27kWh)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11216	16041-10000-36498	6112 W HORNER ST	90035	10	129B173   786	5068006005	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.04959	-118.37515	PV INSTAKLL NEW 2.12 KW DC ROOF-MOUNTED SOLAR SYSTEM. SINGLE FAMILY HOUSE.(8) MODUKLES: KYOCERA KU2656ZPA(1) ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11217	17041-20001-36046	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.24912	-118.34256	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.5.2kW unground pv system. (21) 315W pv modules. (1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11218	17041-10000-08638	9340 N PENFIELD AVE	91311	12	198B113    95	2761040017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.24067	-118.56948	PC for energy only, outdoor. Removing HID fixutres and replacing them with New LED ones. Area: 60,700	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11219	16041-10000-34414	8 S BEVERLY PARK	90210	5	150B157   105	4386028019	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Issued	11/17/2016 12:00:00 AM	ADDRESS	34.10889	-118.42209	PV1. GROUND MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 22.8KWac.(100)MODULES-REC SOLAR REC275TP(2)INVERTER-SOLAREDGE TECH SE 11400A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11220	19041-20000-51471	3550 N GLENRIDGE DR	91423	4	159B157    64	2272029012	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			Reviewed by Supervisor	12/26/2019 12:00:00 AM	ADDRESS	34.13529	-118.43217	PV1. INSTALL 22.40 KW DC PV SYSTEM WITH (56) MODULES/OPTIMIZERS AND (2) INVERTERS(SE7600H-US)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11221	18041-10000-38966	221 N WESTMORELAND AVE	90004	13	138B197   515	5501008024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Issued	10/11/2018 12:00:00 AM	ADDRESS	34.07516	-118.28805	"REPLACING AN EXISTING DAMAGED FIRE ALARM PANEL WITH A NEW ONE ""LIKE TO LIKE"" AT THE SAME LOCATION. ALL DEVICES ARE EXISTING TO REMAIN."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11222	08041-20002-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	07/06/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Bulletin 191 - *****NEW HIGH RISE BUILDING - MEDICAL OFFICE (SHELL ONLY)VARIANCE FOR DEFERRED APPROVAL OF FIRE ALARM SYSTEM WAS SUBMITTED.P/check is approved subject to the ""Conditions of Approval"" on a request for modification regarding campus style feeder to a fire pump.*****"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11223	18041-10000-32431	22121 W CLARENDON ST	91367	3	174B101   399	2169026110	(T)(Q)RAS4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.01	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.16978	-118.60882	PLAN CHECK FOR FIRE ALARM SYSTEM - SYSTEM CONSIST OF 1 FIRE ALARM PANEL AND 1110 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11224	14041-10000-22364	12333 W OLYMPIC BLVD Bldg 4	90025	11	123B149   503	4259019014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Public Safety Only			08/18/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	PIN	34.03245819	-118.45766562	new fire warning system -FCP and devices- for core shell of a commercial building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11225	17041-20001-17587	18025 W PARTHENIA ST	91325	12	195B125   776	2768010016	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.2288	-118.52592	EXPEDITED PER APPLICANTS REQUEST.PV1. ADDITION OF 8.4KW TO EXISTING SYSTEM. LINE SIDE TAP. TOTAL SYSTEM 15KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11226	14041-20000-14179	1333 N SAN PABLO ST	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM			Reviewed by Supervisor	06/17/2014 12:00:00 AM	ADDRESS	34.06159	-118.20463	Replace and relocate 600A motor control panel.  Install new air handler units.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11227	17041-10001-38354	10300 N VANALDEN AVE	91326	12	204B121   122	2728019001	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	34.25765	-118.54904	EXPEDITE PER APPLICANT REQUEST.((((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.075KWdc / 11.2KWac.(35)MODULES-SUNPOWER SPR-X21-345-D-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11228	13041-20000-21897	134 S NORTON AVE PV-1	90004	4	138B189  1131	5516008006	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.07194	-118.31692	PV-1. Plan check for Microinverters. 42 microinverters. solar fee cap. final fee period is not an error	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11229	14041-20000-06020	5733 N CAHILL AVE	91356	3	174B121   158	2156010017	RS-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.17555	-118.54919	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 4.3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11230	18041-20000-45468	12208 N DELANTE WAY	91344	12	219B125   107	2601074014	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.29569	-118.52793	Plan check for PV roof mounted system, system size: 19.140kW DC, 17.875kW AC wtih 58 PV Modules and 2 inverters(7.6kW and 10.0KW) connected to 400A Service.Fees $19.51 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11231	16041-10001-32652	3900 W SUNSET BLVD Ste. 103-& 104	90029	13	145-5A203 412	5427007001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	ADDRESS	34.09167	-118.27986	This is plan check only for T24, permit is covered under master # 16041-10000-32652. Changes noted under Delta 6 only: Replace lighting fixtures, update T24 information and floor plan accordingly.<<T-24, PC FOR ENERGY ONLY. URM BUILDING TENANT IMPROVEMENT FOR A NEW COFFEE SHOP & RETAIL SHOP. CHANGE IN USE FROM TAKE OUT RESTAURANT TO SEAT-DOWN CAFE. SCOPE  INCLUDES NEW LIGHTS AND RECEPTACLE. TOTAL AFFECTED AREA IS 2322 SQ. FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11232	15041-10000-08992	7112 N CANBY AVE	91335	3	183B125   320	2125002005	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.1998	-118.53462	Plan check for power only.  Piecemeal planchecks already done for Title 24 and for service upgrade, applicant is submitting panels and wiring for approval per inspector request.  Previous plan checks under:14041-20000-2687515041-10000-01351See comment for final fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11233	15041-10000-22465	454 N CUESTA WAY	90077	5	141B153    90	4362019004	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.08493	-118.44018	Power plan check for a new residential unit with (1) 1200-Amp service 120/208V single phase 3-wire, (13) panel, (19) equipment, and a total of 300 circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11234	17041-30000-04296	1614 S CRENSHAW BLVD	90019	10	126B185   252	5072003026	C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.04424	-118.32846	Plan check for Title 24 only. Project site is a new drive-thru restaurant. Project scope is indoor lighting. Total lighting area = 1,405 sq. ft.Note: Building application has been generated under 16010-20000-04262	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11235	17041-10000-35179	400 S WESTERN AVE 204-205	90020	10	135B193   439	5503014026	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.067	-118.30888	PC for power and energy for two first time tenants. Demising single unit into two sub units. Total area of 2750sqft. Installing six new panels, lights, receptacles and equipment. B# 17016-10000-22924.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11236	16041-10000-11737	5283 N EAGLE DALE AVE	90041	14	165A217    54	5680027003	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.14517	-118.22823	PV1, INSTALL 5.7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (22) MODULES: SOLARWORLD SW260 POLY(1) INVERTERS FRONIUS PRIMO 5.0-1 240V:	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11237	17041-10000-08488	810 E PICO BLVD 225	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.03119	-118.25079	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE(RETAIL). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1410 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11238	12041-10001-09171	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.0754	-118.38272	CHANGES TO APPROVED SET OF PLAN. PERMIT HAS NOT BEEN PULLED YET. CHANGES HAVE BEEN CLOUDED AND A SHEET OF CHANGES HAS BEEN INCLUDED. LOCATION OF NEW EQUIPMENT HAVE BEEN MOVED. SEDARS SINAI . AS-BUILT SET OF PLANSNew switch boards, 625 kva generator, , mechanical equipment, circuits for first floor of  an existing 2-story, Cedar's Sinai Laboratory building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11239	16041-20000-40242	219 S LA FAYETTE PARK PL 1-33	90057	13	136-5A203 125	5155014014	R4-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.06886	-118.27977	"""0$ permit fees due to senate bill 1222""Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 38.5kW (7.7*5) ungrounded system. (155) 340W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11240	11041-20000-01148	5601 N DE SOTO AVE B0904A	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			01/20/2011 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check T24 energy for office/storage TI for Kaiser. None patient care area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11241	15041-20001-27144	10618 N WHITEGATE AVE	91040	7	207A195   221	2556014056	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.26207	-118.30465	Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11242	12041-10000-28198	10118-10120 W EMPYREAN WAY bldg #12 &-#13	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Apartment			11/26/2012 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.05347	-118.40925	REPLACING EXISTING SWITCHGEARS WITH NEW EQUIPMENT LIKE TO LIKE (SAME RATINGS) DUE TO WATER DAMAGE.  REPLACE THE 2,000AMP PULL SECTION, TWO 800 AMP SECTIONS. NO NEW LOAD ADDED. ALL THE UNIT FEEDERS AND UNIT PANELS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11243	17041-20000-37266	19538 W LEMARSH ST	91324	12	204B117   338	2726015009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Re-Activate Permit	01/06/2020 12:00:00 AM	ADDRESS	34.25533	-118.55921	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11244	14041-10000-08537	7021 N DE SOTO AVE	91303	3	183B109   937	2138027026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.19813	-118.58871	PV1 5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE5000A-US}]. [(20)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11245	16041-20000-38644	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Issued	12/02/2016 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for energy only. T.I. to lab (ICM Line Clean Room). New lighting (including emergency). 751sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11246	14041-20000-17247	800 W OLYMPIC BLVD 5TH FL.	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.04484	-118.26453	T.I. to existing building partial of 5th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11247	19041-20000-37399	22801 W MARLIN PL	91307	12	183B097   477	2026025016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.19701	-118.62368	Plan check for Tesla battery 13.2KWh on existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11248	19041-10000-35237	18205 W SHERMAN WAY	91335	3	186B125   891	2119028015	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Approved	09/05/2019 12:00:00 AM	ADDRESS	34.20135	-118.52968	Change to an approved set by reflecting main equipment to the existing condition, relocating office and lighting fixture to match with floor plan. All changes under delta-1 only.Original electrical plan check # 19041-10000-33383(((CHANGE OF USE FROM RETAIL TO VETERINARY CLINIC TENANT IMPROVEMENT (3752 SF). BULDING PERMIT: 19016-10000-08003)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11249	18041-10000-34092	15104 W HAMLIN ST	91411	6	180B145   598	2235019016	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Issued	09/06/2018 12:00:00 AM	ADDRESS	34.18843	-118.462	Plan check for a 5kW ground mounted system with (16) modules and (1) 5kw inverter inter connecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11250	13041-10000-08890	750 S LAMAR ST INBOUND-PORTAL	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	PLAN CHECK POWER FOR NEW UNOCCUPIED ACCESSORY STRUCTURE HOUSING AUTOMATED SECURITY SCANNING EQUIPMENT FOR INBOUND TRUCK/TRAILER COMBINATIOIN AT UNION PACIFIC RAILROAD LATC YARD. EXISTING SERVICE. NEW PANEL AND BRANCH CIRCUITS. SITE LOCATED IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11251	19041-10000-46859	712 E 120TH ST	90059	15	084B205  1191	6086026029	RD2-1XL-CPIO	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	33.92354	-118.26164	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 4.48KWdc/3.8KWac. SCOPE OF WORK IS 14 MODULES (HANWHA  Q PEAK 320) WITH OPTIMZERS (SEP320) AND A CENTRAL INVERTER (SE38000). MAIN PANEL UPGRADE TO PULLED UNDER SEPARTE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11252	15041-10000-43290	888 S FIGUEROA ST #170	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.0465	-118.26225	Energy plan check for a take out restaurant T.I. converting from a retail.; Scope includes new lighting, equipment, and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11253	15041-10006-16378	940 S FIGUEROA ST basement-5th floor	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM			PC Approved	04/18/2018 12:00:00 AM	ADDRESS	34.04538	-118.26335	[[[4/18/18 CHANGES TO APPROVED SET. DELTA  6 CHANGES. PLANCHECK ONLY.  RENAMING MOTOR AS CT1 , INCLUDING SERVICE RATED DISCONNECT/OVERCURRENT FOR FIRE PUMP, CHANGING FIREPUMP FEEDER SIZE,OF A VFD TO CONTROL (4) MOTORS. ]]]][[[4//11/18 CHANGES TO APPROVED SET. DELTA 5 CHANGES. PLANCHECK ONLY.  INSTALLATION OF A VFD TO CONTROL (4) MOTORS. ]]]]09/27/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the fire pump wiring and fused disconnects.09/12/2016 Changes to an approved set of plans. Changes include the relocation of power equipment to a new electrical room. All changes have been clouded and marked as Delta 4. Note: Building application for the new electrical room is under 14016-10003-1352805/04/2016 Changes to an approved set of plans. Changes have been made to provide power to electrical equipment. Transformer has been added to change voltage class to power said equipment.02/18/2016  CHANGES TO APPROVED SET. ADDITION OF FIREPUMP AND JOCKEY PUMP TO THE SYSTEM REQUIRED BY MECHANIAL*****Previous Work Description*****New service upgrade and distribution equipment for assembly occupancy. new design. This is core and shell clear out of existing building. TI package will be submitted at a later date. per building submittal, PC is accordance to 2008 building efficiency standards.project is in methane buffer zone. NOT A HIGHRISE PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11254	18041-10000-26790	3602 S 6TH AVE	90018	10	120B189  1229	5044027001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.02274	-118.32345	PLAN CHECK FOR ROOF MOUNTED 3.3KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(PVI-3.3-OUTD-S-US-Z-A) WITH 10 PANELS(SOLARCITY)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11255	15041-20000-16312	936 S OLIVE ST UNIT 349	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #15 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11256	14041-10001-13412	5901 S NORMANDIE AVE	90047	8	105B193   164	6002011037	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.01	Electrical	Electrical	Apartment			09/17/2014 12:00:00 AM			PC Approved	09/17/2014 12:00:00 AM	PIN	33.98728785	-118.30041591	[[[9/17/14  CHANGES TO APPROVED SET OF PLANS. T24 CHANGES ONLY. CHANGE OF FIXTURE TYPE FROM FLUORESCENT TO LED]]]]NEW SERVICE AND PANELBOARDS AND TITLE 24 FOR 5-TENANT SPACES AND EXISTING MARKET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11257	14041-20000-25612	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	PIN	34.05243427	-118.25124731	PC FOR T24 ENERGY ONLY. ADDITION OF LIGHTING TO EXISTING LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11258	12041-20000-30206	9337 GLORY AVE	91042	2	198B201   345	2572044009	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Closed	01/21/2015 12:00:00 AM	PIN	34.23851513	-118.27985693	8.64kw rooftop photovoltaic system for an existing single family residence.  System is transformerless, ungrounded, system. Applicant provided proof of insurance proving current registration.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11259	19041-20000-46964	3202 W ADAMS BLVD	90018	10	123B189   714	5052015032	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.03243	-118.31914	Plan check for power only, new 100 Amp panel served class rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11260	12041-10000-07920	555 W 5TH ST 5TH FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/06/2012 12:00:00 AM			PC Approved	04/06/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	condtruction of new conference room and private office PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11261	17041-10000-31280	7861-7901 W FOOTHILL BLVD	91040	7	204B193    90	2556029012	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.2598	-118.30475	PC FOR 600A SERVICE UPGRADE. SHELLING OUT COMMERCIAL SPACE. SCOPE OF WORK DOES NOT INCLUDE ANY RECONNECTION. SERVICE SECTION AND POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11262	16041-10000-09659	1167 S HOOVER ST	90006	1	129A201    16	5076014041	R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.04967	-118.28446	PC FOR FA SYSTEM. TOTAL 149 DEVICES FOR APARTMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11263	14041-20000-17273	626 W WILSHIRE BLVD 5TH FLOOR	90017	14	129A209    83	5144006025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.04843	-118.25695	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY ONLY.  EXISTING HIGH RISE BUILDING DIRECT REPLACEMENT OF LIGHTING FIXTURES ON THE FIFTH FLOOR ONLY.  NO NEW LOADS.  ALL CIRCUITS ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11264	19041-20000-47985	23800 W KENSINGTON CT	91304	12	186B089   461	2027024028	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	PIN	34.20517638	-118.64660008	PV1.  Install 7.36 kW DC roof mounted grid tied PV system.  (23) modules with 5 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11265	15041-20000-19287	7602 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.20865	-118.46478	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11266	19041-20000-47588	800 N BROOKTREE ROAD	90272	11	126B129   189	4409018001	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM			PC Approved	09/14/2020 12:00:00 AM	ADDRESS	34.04421	-118.51392	Plan check only for new 600A 240/120V 1ph-3w service, distribution, power, and lighting for new construction.  Permit paid under combo building permit 18010-30000-05561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11267	17041-10000-04410	12763 W SHELL PL	90094	11	102B161  1270	4211037208	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	33.9748	-118.41646	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 4 STORY, THREE UNIT CONDO APARTMENT BUILDING. SCOPE INCLUDES ADDING 59 FA DEVICES, AND 4 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11268	12041-20000-16309	12925 W MAGNOLIA BLVD	91423	4	171B161   450	2345017031	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.16502	-118.41473	T.I. to existing space.  Install new lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11269	18041-10000-44857	6443 N TOPANGA CANYON BLVD	91303	3	180B101   691	2139002019	(WC)TOPANGA-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.18771	-118.60623	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTOURANT. SCOPE OF WORK INCLUDES NEW 800AMPS SERVICE,120/208 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 4,175 SQFT NEW LD# 18010-10000-05626	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11270	15041-20000-09587	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BRICKS LUGGAGE STORE. NEWLY CONNECTED LOAD <400 AMPS. 1815 SQFT, EMERGENCY LIGHTING. SPACE #B1-121	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11271	14041-20000-28183	17119 W CANTARA ST	91406	6	192B133   376	2204003019	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Expired	11/03/2016 12:00:00 AM	ADDRESS	34.21956	-118.50622	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW. 2 strings of 11 modules. Using power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11272	14041-20000-24071	9670 N DONNA AVE	91324	12	201B121   434	2762032029	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.24691	-118.54739	PV1Install roof-mounted solar array on SFD. Interconnect with MSP. System size: 6kW.(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(27) Kyocera KD255GX-LFB3 pv modules(27) SolarEdge P300 power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11273	13041-10000-29506	5706 N MURIETTA AVE	91401	2	174B153   525	2246018020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.17418	-118.43874	PV1.  Install 4.25 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE6000A-US.  17 modules: HANAWHA # HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11274	18041-10000-37201	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	New Methane Mitigation Design Level IV on a 8-Story Media Production Office Building over 2 level subteranian parking space.  (1) Panel    (19) Devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11275	13041-10000-05453	17033 W KNAPP ST	91325	12	198B133   366	2692021009	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.23849	-118.50365	PV1 FOR 2 STORY HOUSE.  12.50 KW DC SYSTEM SIZE.  {51 MODULES: YINGLI SOLAR YGE 245} {2 CENTRAL INVERTERS: 1x PVI-4.6-I-OUTD-US AND 1x PVI-6000-OUTD-US (TRANSFORMERLESS)}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11276	16041-20000-43227	303 E 52ND ST	90011	9	108B205    70	5109024019	RD1.5-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	33.99537	-118.26985	TI to (E) recovery house.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11277	14041-20001-01334	16640 W BRYANT ST	91343	12	195B137   900	2689021013	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/27/2014 12:00:00 AM	ADDRESS	34.2274	-118.49544	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11278	18041-10000-12904	5567 N RESEDA BLVD	91356	3	174B125   446	2160004***	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.17168	-118.5362	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11279	18041-10000-12128	729 S BERENDO ST	90005	10	132B197   320	5094009015	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			04/04/2018 12:00:00 AM			Verifications in Progress	06/14/2018 12:00:00 AM	ADDRESS	34.05886	-118.29429	NEW ROOF MOUNTED PV SYSTEM ON AN APARTMENT BUILDING.SCOPE INCLUDES 8 MODULES AND CENTRAL INVERTER. TOTAL SYSTEM SIZE 2.4KWDC /3.0 KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11280	17041-10000-06362	222 W 6TH ST 4th FLR	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	33.73887	-118.28305	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11281	17041-10000-01292	4501 W DON TIMOTEO DR	90008	8	114B177   423	5027008019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM			Corrections Issued	01/13/2017 12:00:00 AM	ADDRESS	34.00514	-118.35473	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(20)MODULES-SW 290 MONO(1)INVERTER-SOLIS-5K-2G-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11282	19041-10001-12874	6801 W HOLLYWOOD BLVD C1-134	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM			PC Approved	09/09/2019 12:00:00 AM	ADDRESS	34.10229	-118.33907	"DELTA  H CHANGES TO APPROVED PLANS: REVISED LIGHTING LAYOUT IN ALL AREAS, CHANGED MFG OF LIGHTING CONTROL SYSTEM, UPDATED KEYED NOTES AND PHOTOMETRIC PLAN,AND ADDED 120V RECEPTACLES. ALL CHANGES ARE CLOUDED AND MARKED ""DELTA  H"" (((((((((((POWER AND ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT. CHANGE OF USE FROM FOREVER 21 TO CAPITAL ONE BANK OFFICE, ATM, AND CAFE SPACE."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11283	16041-20000-10226	6503 S 2ND AVE	90043	8	105B189  1611	4007026029	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	PIN	33.98090065	-118.31994899	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZEk 2.9KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11284	12041-10000-03806	510 S LANDFAIR AVE 1-14	90024	5	135B149   156	4363005046	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.04	Electrical	Electrical	Public Safety Only			02/21/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.0683	-118.4506	New fire alarm system for 36 units appartment Bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11285	14041-10000-21387	14402 W CALIFA ST #1	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11286	14041-10006-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Closed	05/11/2020 12:00:00 AM	ADDRESS	33.95713	-118.3847	Delta 9 revisions :  adding HVAC VRF SPLIT SYSTEMS FOR UNIT PANELS B4 AND C3 AND UPDATING PANEL LOAD CALCULATIONS; NEW FOOR PLAN AND PANEL SCHEDULE  FOR UNIT C2.1; REMOVE CIRCUIT # 25 FROM PANEL C2ON THE PLANS, THE CHANGES ARE CLOUDED AND IDENTIFIED AS Delta 9	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11287	13041-10000-29904	10000 W SANTA MONICA BLVD	90067	5	135B161    35	4319001001	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.06351	-118.41446	PLAN CHECK FOR POWER AND ENERGY FOR A NEW 40-FLOOR HIGH RISE APARTMENT BUILDING. 283 UNITS.  METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11288	16041-20000-17072	16919 W ROSCOE BLVD	91325	12	192B133   227	2205001009	M2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.22139	-118.50178	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.  TOTAL SQUARE FOOTAGE 1824.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11289	18041-10000-19974	963 E 4TH ST GND FLOOR	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM			PC Approved	05/30/2018 12:00:00 AM	ADDRESS	34.04337	-118.23442	NEW LIGHTING SYSTEMS IN MAIN LOBBY AND STAIRS AND CORRIDORS  OF AN OFFICE BUILDINGALSO LUMINAIES FOR SMALL AREA OUTSIDE THE BUILDINGPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11290	12041-10000-23449	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/02/2012 12:00:00 AM			PC Approved	10/02/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	ON THE 36TH FLOOR , CONVERT CORRIDOR SPACE TO ENCLOSED SERVER ROOMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11291	11041-20000-26888	14629 W NORDHOFF ST	91402	6	198B149   557	2651009021	[T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.23558	-118.45117	Approved  set of plan has been lost ( 10041-200000-19789 & 10041-20001-19789 ). Plan check power for chapel auditorium (place of assembly)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11292	15041-20001-43396	7355 N BALBOA BLVD	91406	6	186B133   803	2227001050	(Q)RD1.5-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Apartment			01/15/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.20442	-118.50145	Expedite per applicant request{{{{{Plan check for PV roof mount system on Appartmet building. System size: 10 kWac with 32 modules and 2 inverters(5.0kW and 5.0kW)}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11293	12041-20000-30163	7401 N SHOUP AVE	91307	12	186B101   532	2022019023	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM			PC Info Complete	12/14/2012 12:00:00 AM	ADDRESS	34.20486	-118.61489	Adding AC-3 and AC-4 to the installation approved on application number 12041-20000-18622.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11294	19041-10000-07212	7755 W SUNSET BLVD 1ST & 2ND	90046	4	147B177   985	5551021020	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.09823	-118.35855	PC FOR T-24 ONLY FOR AN INTERIOR OFFICE TENANT IMPROVEMENT ON TWO FLOORS. TOTAL AFFECTED AREA IS 243 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11295	18041-20001-18634	269 S MARIPOSA AVE	90004	10	135B197   154	5518007030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Apartment			08/07/2018 12:00:00 AM			PC Info Complete	08/07/2018 12:00:00 AM	ADDRESS	34.06948	-118.29938	Plan check for Temp power hazardous location, 250A Service with 400A equipment. 400A equipment shall locate 30 feet away from Pull Section(Inspector to verify distance of Service equipment.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11296	18041-10000-33397	5958 N LANKERSHIM BLVD	91601	2	177B169   862	2338010026	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.17911	-118.38299	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11297	15041-30000-39663	6060 W CENTER DR Suite 100	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			PC Approved	11/24/2015 12:00:00 AM	ADDRESS	33.97602	-118.39073	Title 24 plan check only.  Total area = 6,650 sq. ft.   T.I. to existing commercial office highrise.  Two new panels (load < 400 A).  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11298	19041-10000-53497	12663 N SAN FERNANDO ROAD	91342	7	219B145   182	2604028031	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	02/22/2021 12:00:00 AM		Permit Finaled	10/03/2022 12:00:00 AM	ADDRESS	34.29925	-118.45984	Scope of work includes new power equipment. Adding new panelboards, circuits, and 1 transformer connected to new 1600A bus.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11299	19041-10000-11962	501 E FLORENCE AVE	90003	9	102B205   764	6011008042	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	33.97489	-118.26619	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11300	10041-10001-12419	11414 W CHALON ROAD	90049	5	144B145   240	4369027003	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			02/02/2011 12:00:00 AM			PC Approved	02/02/2011 12:00:00 AM	ADDRESS	34.08807	-118.46354	ADD NEW FIRE ALARM DEVICES TO EXISTING FIRE ALARM SYSTEM PER T.I. AT ACADEMIC BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11301	14041-10002-21976	12827 W VICTORY BLVD	91606	2	180B161  1043	2325032012	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.18684	-118.41269	Change to an approved set by modifying the panel 1LA into (2) seperated panel. Additional circuits also added. per F.Y(((PLANCHECK FOR POWER AND ENERGY.TENANT IMPROVEMENT TO AN EXISTING 8 SCREEN CINEMA. PLACE OF ASSEMBLY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11302	16041-10000-18455	21650 W OXNARD ST 10TH FL.-STE.1000	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	PC FOR T-24 ONLY. TI TO AN EXISTING OFFICE BUILDING 10TH FLOOR, NEW CONNECTED LOAD LESS THAN 400A. INSTALL NEW LIGHTS AND CONTROLLED RECEPTACLES. TOTAL AREA: 1,280 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11303	15041-20000-26244	3523 S CENTINELA AVE	90066	11	114B153   477	4246006001	[Q]C1-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.00999	-118.43857	PLANCHECK FOR T24 ENERGY ONLY.   TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING. CHANGE TO A  RESTAURANT 1660 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11304	18041-10000-15198	940 W WASHINGTON BLVD	90015	1	124-5A203  17	5124016028	(Q)CM-1-HPOZ, (Q)CM-2-HPOZ, (Q)P-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.03722	-118.27888	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11305	13041-10000-14462	6112 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	34.09785	-118.32289	PLAN CHECK ONLY APPLICATION IN REFERENCE TO PERMIT NUMBER 12041-20000-03063. TITLE 24 PART 6 ENERGY COMPLIANCE. LIGHTING IN A SINGLE BATHRROM. CORE AND SHELL WITH NO TENANT LIGHTING.*******************************************************************200 AMP PANEL UPGRADE, CIRCUITS FOR OUTLET, SWITCH AND EXHAUST FAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11306	14041-10000-26098	7635 N SEPULVEDA BLVD	91406	6	186B145    74	2222013012	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	PIN	34.20935369	-118.46682857	Plan check for power and energy. 2013 standards. renovation of a tool retail store. Service, Panels, and transformers are existing to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11307	13041-20000-19454	9854 N BOTHWELL ROAD	91324	12	201B117   117	2761032022	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	09/18/2013 12:00:00 AM	ADDRESS	34.24964	-118.56114	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE: 7.3 KW. 30 MODULES AND 2 INVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11308	17041-20000-07716	4235 S REDWOOD AVE	90066	11	108B153  1232	4230006026	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	33.98872	-118.43837	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO DOLLAR SHAVE CLUB OFFICE. 2 STORIES.BULDING PERMIT # 17016-10000-00904	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11309	15041-20003-33032	20790 W NORDHOFF ST Bldg 2-#5	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	Revisions to approved set.  Change of feeder from Cu to Al.  Revision limited to sheet E-3 only.  Restamp on original approved sets approved under 15041-10001-33032(((PC FOR POWER ONLY. FIRST TIME TENANT FOR NEW RESTUARANT. SCOPE INCLUDES THREE NEW PANELS AND BRANCH CIRCUITS.  NOTE: ENERGY PC UNDER PCIS#15041-10000-33032((((((T-24, CHANGE OF USE TO RESTAURANT IN AN (E) BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1315.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11310	19041-10000-47408	6050 W JEFFERSON BLVD	90016	10	117B169     7	4204008011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		7025.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.02066	-118.38059	Plan check for Fire Alarm system, 1 FACP and 65 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11311	12041-10001-03551	6290 W HOLLYWOOD BLVD	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM			PC Approved	07/24/2012 12:00:00 AM	ADDRESS	34.10146	-118.32639	ALTERATIONS TO APPROVED SET OF PLANS- RELOCATING RECEPTACLES; REMOVING REPLACING AN ESPRESSOR MACHINE WITH A DISHWASHER AND INTERFACING PANEL B WITH A SILVER BULLET PANEL TO LIMIT THE CURRENT IN EACH OF THREE CIRCUITSNEW STARBUCK'S COFFEE, CHANGE OF USE FROM RETAIL TO RESTAURANT.  No tenant suite number per applicant, stand alone building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11312	18041-10001-24149	1030 N SWARTHMORE AVE #2-109 &-B1M-114	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	"DELTA 2 CHANGES TO APPROVED PLANS. MODIFIED CIRCUTS, 1-LINE & T-24.<<<PLAN CHECK FOR POWER AND ENERGY - First time Tenant improvement to retail space ""CHANEL"" within Pacific Palisades Village Shopping Center. TOTAL AFFECTED AREA = 979, TOTAL CONNECTED LOAD = 250A.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11313	13041-10000-25314	1406 W MANCHESTER AVE	90047	8	097-5A195 289	6037015028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	33.95984	-118.30079	INSTALLATION OF NEW FIRE ALARM SYSTEM IN A SINGLE-STORY BUILDING. FULLY-SPRINKLERED SYSTEM IN A 3500 SF AREA BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11314	16041-20000-40186	12325 W CHANDLER BLVD	91607	2	171B165    73	2347008014	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.16875	-118.40164	Plan check for the replacement of the FACP capable of elevator recall for an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11315	17041-10000-02741	322 S LINCOLN BLVD C1	90291	11	111B145   651	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	34.00105	-118.46687	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO BARBER SHOP. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 808 SQ. FT. B#16016-10000-28759NOTE: PERMIT IS PULLED UNDER PCIS#16041-30000-40780	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11316	13041-10000-31138	650 S HILL ST STE 308	90014	14	129A211   215	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Issued	11/07/2013 12:00:00 AM	ADDRESS	34.04623	-118.25392	TITLE 24 PART 6 ENERGY ONLY ; LIGHTING WORK IS ON THE 3RD FLOOR. TOTAL AREA IS 3407 SQ FT. SCOPE OF WORK IS < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11317	15041-20000-14810	1542 N CAHUENGA BLVD #201	90028	13	148-5A187 356	5546012004	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.0993	-118.32935	Plan check for title  24 only for T.I. of the restaurant. Total area: 2232 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11318	11041-20000-13289	18412 W OXNARD ST	91356	3	177B125   699	2157001148	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.17983	-118.5339	Replace 1200 Amp main Board. Epc for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11319	18041-20000-05946	11728 W DOROTHY ST 1-27	90049	11	129B145   118	4265006080	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			02/16/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.05254	-118.46581	Plan check for the installation of new emergency lighting and exit signs in the stairwells.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11320	15041-20000-19439	9002 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.23394	-118.55337	Title 24 plan check only.  Total area = 759 sq. ft.  T.I. to existing commercial space.  Change of use from retail to restaraunt.  New lighting, HVAC, and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11321	13041-20000-26270	19527 W VENTURA BLVD	91356	3	174B117   257	2164013007	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.17296	-118.55895	RENOVATION OF PIZZA RESTAURANT. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 1380 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11322	12041-10000-09100	10813 N ZELZAH AVE	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	08/03/2012 12:00:00 AM	ADDRESS	34.26646	-118.52366	Sprinkler monitoring system with full notification and HVAC shutdown.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11323	19041-20000-46078	12644 N BRADFORD PL	91344	12	219B129   410	2601050053	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.29669	-118.52091	Plan check for PV roof mounted system, PV system size: 7.6KW with 19 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11324	14041-20000-06531	523 W 6TH ST R517S	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	T24 FOR CHANGE OF USE OF FIRST FLOOR TENANT SPACE TO JUICE BAR. HIGHRISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11325	17041-30000-00310	214-216 N LARCHMONT BLVD	90004	4	138B189   584	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.07523	-118.32345	Title 24 plan check.  Relocate and expand restrooms in existing single story commercial retail building.  New 75 kVA transformer feeding 200 amp subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11326	13041-20003-29804	1500 W PACIFIC COAST HWY A-L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	33.79072	-118.2857	3.7.2016 - Plan check for modifications to approved set. Recreation building indoor lighting design altered. Recheck to 2008 title 24.===02-18-2016 Change to approved set of plans. Changes include panel load(Methane load, exhaust fan load for Methane Detection System) UL listed panel for methane Detection System are not part of the plan. Methane Detection Panel are attached as cutsheet for each building (13 Buildings)Changes apply to Delta 13 only. Note: Methane Detection System Application reffer to 15041-10000-12870****************Previous work description****************************************************************************************************************************************************************************************************BUILDING A:   NEW APARTMENT COMPLEX CONTAINING 12 SEPERATE BUILDINGS UNDER THE SAME ADDRESS. (2) 4000A SERVICES. PER APPLICANT REQUEST SUBMITTED AS ONE LUMP SUM. METHANE ZONE, HAS METHANE REPORT.Note: Variance to separate Methane Detection System has been filed.Permit Bld. B is under 14041-20000-06842Bld. C is under 14041-20000-06845Bld. D is under 14041-20000-06846Bld. E is under 14041-20000-06848Bld. F1 is under 14041-20000-06850Bld. F2 is under 14041-20000-06875Bld. G is under 14041-20000-06852Bld. H is under 14041-20000-06853Bld. I is under 14041-20000-06854Bld. J is under 14041-20000-06856Bld. K is under 14041-20000-06858Bld. L is under 14041-20000-06859Bld. Recreation is under 14041-20000-06860*************************************************************************************************************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11327	18041-10002-40903	9401 N DE SOTO AVE	91311	12	198B109    69	2746008007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.24091	-118.58876	INSTALLING 999.9 KWAC ROOFTOP PV SYSTEM, ON EXISTING WAREHOUSE3152 MODULES, 10 (50.1-100KW) INVERTERS, 2 1600A PANELS, 90 BRANCH CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11328	14041-10000-19581	4422 W ADAMS BLVD	90016	10	123B185   734	5050001028	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.03237	-118.33593	plan check for power and energy (2010 standards). NEW 1 STORY COMMERCIAL BLDG FOR COIN LAUNDRY. BLDG#?Building application #:13010-10000-01734	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11329	11041-20000-13827	8820-8826 N LANKERSHIM BLVD	91352	6	195B169   273	2631016039	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	02/10/2012 12:00:00 AM	ADDRESS	34.22994	-118.38756	PLAN CHECK FOR NEW 800A SERVICE ELECTRICAL SYSTEM AND ENERGY FOR EXISTING COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11330	19041-20000-43118	3502 S NORMANDIE AVE	90007	8	120B197   732	5040004025	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	07/10/2020 12:00:00 AM	ADDRESS	34.02419	-118.30009	Plan check for Title 24 energy only lighting. Total area: 1697 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11331	18041-10000-07705	1601 S VICTORIA AVE	90019	10	126B185   134	5071004001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	ADDRESS	34.04485	-118.32987	PC for 5kW rooftop solar system in SFD with Tesla battery(Covered under 18041-10002-07705 ). Installing 15 modules [7.875kW(DC)], 200A panel and central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11332	15041-20000-40197	6316 N TOPANGA CANYON BLVD Building C	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.18578	-118.60514	0$ permit fees due to senate bill 1222.Plan check for a PV2 roof-mounted PV system. System size 84 kWac and consists of (3) inverters, (1) load center, and (285) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11333	19041-10000-43401	2390 W PICO BLVD	90006	1	129B197  1082	5056003027	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.0471	-118.28887	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11334	16041-20000-41638	13326 N RALSTON AVE	91342	7	225B141   151	2501002061	[Q]MR1-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.31414	-118.47437	Service upgrade to 800A 120/240V 3ph-4w with new CNC machines and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11335	14041-20000-07578	10127 N BREIDT AVE	91042	7	204B201  1103	2570004034	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.2522	-118.27407	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11336	14041-10000-32120	2330 S SEPULVEDA BLVD	90064	5	126B153  1076	4322021004	M2-1VL	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.038	-118.43573	this is one story office , title 24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11337	19041-20000-09211	20144 W MONTERIA PARK ROAD	91311	12	207B113   331	2707003029	(Q)A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Closed	10/12/2023 12:00:00 AM	ADDRESS	34.26697	-118.57268	PV1.  Install 19.22 kW DC / 15.4 kW AC roof mounted grid tied PV system.  (63) modules with (2) 7.7 kW rated string inverters.  $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11338	16041-20000-36293	3311 N CAHUENGA BLVD WEST	90068	4	159B181   579	2425026002	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.13039	-118.35042	ti to an existing commercial building.  adding new lighitng new controls to new panels.  newly connected  load <400 amps.  plan check for energy and em lighting.  total square footage 2706.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11339	14041-10001-07071	1240 S NAOMI AVE	90021	14	121-5A213  54	5130006900	PF-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM			Verifications in Progress	05/14/2014 12:00:00 AM	ADDRESS	34.02783	-118.24431	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11340	14041-10000-10000	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	PIN	34.12750533	-118.21285206	T24 FOR EXISTING COLLEGE RESTROOM AND EM LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11341	18041-20000-17700	11601 W WILSHIRE BLVD 4th FL-Lobby	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing space T.I. Lobby and corridor. Total area: 1285 sq ft.B#18016-10000-13111	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11342	18041-20001-48745	19513 W LANARK ST	91335	3	189B117    13	2105002025	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.21808	-118.55863	expeditepv1install roof mounted pv system sized 7.6KW AC interconnetced with msp.(1) tesla battery 5KWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11343	13041-10002-30090	12622 W GILMORE ST	91606	2	180B161  1009	2325018011	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.18747	-118.40809	Expedited RSES plan check per applicant request.(((PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 10 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11344	09041-20003-22007	440 S VERMONT AVE	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	01/18/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Delta 5 modifications to the approved set of plans. Changes include new panel, new circuits, new equipment, and T-24 energy general/emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11345	14041-10000-33513	6116 W ELEANOR AVE	90038	13	144B189   780	5534024005	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.08971	-118.32506	Installation of a roof-mounted PV system. System consists of (3) inverters and (80) modules in (8) strings. System size is 20.4 kWac. Zoning cleared on building application	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11346	12041-20000-19547	14006 W RIVERSIDE DR #265	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24 lighting plan check for remodeled TENANT IMPROVEMENT OF (E) RETAIL STORE. ALL WORK PER ARCHITECTS DESIGN.(SEE COMMENTS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11347	11041-10000-18138	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	08/31/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.01303	-118.24279	Two existing services in the bldg, rmoving loads from service A and reconnecting to service B and added new loads and vice versa., new feeders, DP board and addition of 400 amps meter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11348	17041-20000-43964	5422 N KATHERINE AVE	91401	4	171B153    32	2245024020	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	Apartment			12/07/2017 12:00:00 AM			Reviewed by Supervisor	12/21/2017 12:00:00 AM	ADDRESS	34.16937	-118.44311	PV1.  Install 11.7 kW PV system with 27 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11349	13041-20002-26796	11308 N SINCLAIR PL	91326	12	213B121   862	2871020010	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.27631	-118.5395	PV1 MICROINVERTER PLAN. TOTAL SYSTEM SIZE 7.3KWAC. 34 PANELS AND MICROINVERTERS(((changes to approved set of plans. new strings sizing and change in description of disconnect. total number of modules no change. ))) pc for new single line onlydue to senate bill 1222 from 2012, no plan check fee due ($0)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11350	14041-10001-03305	777 W 190TH ST	90248	15	060B201    48	6121021006	[T][Q]M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.86037	-118.28753	plan check only. plan check for power only. CHANGE OF DESIGN. fees on original permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11351	14041-10000-25151	355 E 1ST ST	90012	14	129A215    13	5161012903	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.04958	-118.23946	Fee estimate only for title 24 plan check; new load and equipment have been added on the plan and the load may be more than 400 amp. plan check engineer need to request for confirmation of new  load added in case  suplimental application neededfor power plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11352	12041-20000-23793	21937 W VENTURA BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	PIN	34.16940578	-118.60503747	T.I. to an existing retail/commercial space.  Load is 366.8 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11353	16041-20000-43611	10250 W CONSTELLATION BLVD 8th & 9th-Floors	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for power and energy. TI to office on 8th and 9th floors of high rise building. New lighting (incl. emergency) and receptacles. ~>400A of new load. 29,301sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11354	15041-10000-09968	2257 S FEDERAL AVE	90064	9	121-5A205 243	5126036008	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.03387	-118.44493	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHTING FIXTURES AND REPLACE WITH LEDS.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 4776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11355	16041-10004-29528	821 S MATEO ST	90021	14	123A217    49	5166017013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.03285	-118.23244	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES INCLUDE USE OF SINGLE 12KW INVERTER. UPDATED PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11356	13041-20000-18454	18610 W HART ST	91335	3	183B121   559	2126019019	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.19755	-118.53912	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.9 KW. USING 23 MODULES. USING ENPHASE MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11357	13041-20001-18784	2130 S SAWTELLE BLVD 1-2	90025	11	126B153   959	4260001031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/30/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	34.03882	-118.4416	((CHANGES MADE TO APPROVED SET OF PLANS.))T24 FOR COMBINING 3 UNITS INTO 1. PLAN CHECK FOR ENERGY ONLY. TOTAL SQRFT 3552	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11358	18041-20000-22658	11857 RICASOLI WAY	91326	12	216B109    67	2701078013	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	PIN	34.28827647	-118.58484161	PV1.  Install 10.56 kW DC roof mounted grid tied PV system.  (32) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11359	15041-20000-34350	300 S GRAND AVE 29th Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for Title 24 only in existing high-rise for Mckool, Smith & Hennigan. Total area: 15,580 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11360	15041-20003-10598	6250 W HOLLYWOOD BLVD SUITE 100	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.10133	-118.32547	10-21-2015 New plan check for title 24 only T.I. for restaurant in existing space. Total area: 1,770 sqft. Note:  Applicant lost part of the plan. {{{{{{{{PC FOR T24 ENERGY ONLY. TI TO A BAR. SOME NEW LIGHITNG.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11361	17041-10000-37946	1501 N SUMMITRIDGE DR	90210	5	147B157   193	4355005039	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			Reviewed by Supervisor	11/01/2017 12:00:00 AM	ADDRESS	34.09868	-118.41997	PV1 ground mounted system.total system size is 32.4KWdc / 30.24KWac.108 modules- SolarWorld SW300 mono.108 microinverters- Enphase S280-60LL-5-US.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11362	13041-10001-34197	380 WORLD WAY Space T45	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Modifications to approved set for changes to proposed lighting system.  Adjustments to placement of low-voltage lighting on reflected ceiling plan.  (((plan check per INSPECTOR for installation of listed luminaires. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11363	13041-20000-16768	879 W 190TH ST	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	33.85951	-118.28963	Change to lighting to an existing high-rise office building.  Load is less than 400 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11364	18041-10002-07705	1601 S VICTORIA AVE	90019	10	126B185   134	5071004001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	ADDRESS	34.04485	-118.32987	PC for Tesla powerwall installed with PV (PV under 18041-10000-07705)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11365	13041-10000-01122	1601 S SOTO ST	90023	14	120A221   205	5169014003	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM			Corrections Issued	01/15/2013 12:00:00 AM	ADDRESS	34.02091	-118.2204	2ND STORY ADDITION INSIDE EXISTING WAREHOUSE AND NEW OFFICE AT GROUND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11366	15041-10000-35171	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	03/30/2017 12:00:00 AM		Issued	03/30/2017 12:00:00 AM	ADDRESS	33.76094	-118.29308	PV2, SOLAR ROOF MOUNTED SYSTEM TO AN (E) COMMERCIAL BUILDING, TARGET. TOTAL SIZE 364 KW, AC. (1547) MODULES AND (13) INVERTERS. (1547) JINKO JKM310P-72(13) SOLELECTRIA PV1-28TL-480Note: Fees $0 Due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11367	18041-20000-22635	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Issued	06/18/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Addition of ground fault protection to (E) PV system with supply-side connection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11368	18041-10000-40512	8500 W BEVERLY BLVD 764 A & B	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	T-24, ENERGY ONLY. CHANGE OF USE FROM RETAIL TO REMOTE STORAGE SPACES A & B FOR (E) RETAIL SPACES IN A COVERED MALL. TOTAL AFFECTED AREA = 751 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11369	11041-10000-20636	1621-1633 S PENMAR AVE BLDG 30	90291	11	111B149   261	4243001043	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.00304	-118.45774	LINCOLN PLAZA APARMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11370	15041-20001-28666	3150 W WILSHIRE BLVD 2ND FLR-SUITE I	90010	10	132B197   112	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.06163	-118.29086	**11/4/15: Changes to an approved set of plan: relocating Water Heater and Washer/Dryer.PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT PER APPLICANT. YOGA STUDIO - ON 2ND FLOOR. SUITE I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11371	17041-10000-19755	8943 N OSO AVE D	91311	12	195B113    39	2781001016	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.23374	-118.57549	REPLACE  LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11372	16041-20001-02883	7900 N BALBOA BLVD BLDG 'I'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	4.13.2016 - Plan check for modifications to approved set. Change size of breakers feeding panels G3, G4, G5, G7, and G8 from 40A to 60A, and update each panel's feeder sizes. Remove T.C. detail from sheet E-5.===Plan check for power and energy Aircraft Hangar Building 'I' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' I' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11373	16041-20000-27201	9301 N TAMPA AVE FC2	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI TO AN EXISTING COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  NO NEW LOADS REARRANGEMENT OF EXISTING CIRCUITS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 880.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11374	13041-20000-18248	2319 S BAGLEY AVE	90034	5	126B169   800	4309019018	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	34.04062	-118.39221	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.4 KW USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN TOTAL OF 26 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11375	16041-10000-23293	11929 W ALLEGHENY ST	91352	6	198B165   177	2631001016	RA-1, [Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	PIN	34.23743306	-118.39337734	INSTALLATION OF NEW FIRE ALARM SYSTEM IN 2 STORY TYPE IIIA SPRINKLERED MIDDLE SCHOOL AND HIGH SCHOOL WITH  ONE LEVEL OF  UNDERGROUND PARKING GARAGE.  TOTAL SYSTEM SIZE = 248 DEVICES + 1 FACP     PROJECT INCLUDES 11933, 11937, & 11941 ALLEGHENY ST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11376	16041-20000-40324	1408 N POINSETTIA PL Unit #C	90046	4	147B181   927	5548019036	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.09607	-118.3481	Plan check for power only. New SFD - unit C - part of 5 attached SFDs fed from (N) common 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11377	19041-10000-26143	13574 W FOOTHILL BLVD	91342	7	222B157   200	2513006900	RD1.5-1XL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	12/15/2020 12:00:00 AM	ADDRESS	34.30647	-118.42954	INSTALL (149) NEW FIRE ALARM DEVICES IN APARTMENT BUILDING AND (1) FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11378	16041-20000-02864	1723 W 66TH ST	90047	8	102B193   227	6015012037	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	33.97922	-118.30757	Plan check for a Pv1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11379	10041-10000-05199	633 S MISSION ROAD	90023	14	124-5A219   3	5171015001	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	PIN	34.0373651	-118.22637397	Major revision of  cold storage warehouse building.  Power and energy.  The service is existing.  The site is in a Methane Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11380	13041-20001-28560	10348 N STAFFORD LANE	91311	12	204B113    84	2707015015	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.25886	-118.57759	EXPEDITE FEES ONLY.<<<New 10.2 kw UNGROUNDED rooftop PV system for an existing single family dwelling.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11381	10041-20000-12870	21255 W BURBANK BLVD STE 140	91367	3	174B105    78	2149019009	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	08/18/2010 12:00:00 AM	ADDRESS	34.17432	-118.59446	TI IN OFFICE AREA. P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11382	16041-10000-43036	17136 W VENTURA BLVD	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.16014	-118.50667	PC for T24 only installing new lights and receptacles. Connected load under 400 A. Total affected area is 1875 SQ. FT.** NEW BAKERY WITH EXISTING OUTDOOR EATING AREA.  CONSTRUCT NEW AWNING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11383	16041-20000-17098	1320 S KENISTON AVE	90019	10	129B185   598	5083024018	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Expired	06/18/2018 12:00:00 AM	ADDRESS	34.05053	-118.33866	CHANGES TO AN APPROVD SET OF PLANS.  CHANGES TO REFLECT FIELD INSTALLATIONS.PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-20000-12637PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11384	17041-10000-44445	18840 W VENTURA BLVD #207	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.17186	-118.54425	FULL PLAN CHECK CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE. SCOPE INCLUDES NEW PANEL AND EQUIPMENT. TOTAL AFFECTED AREA 3367 SQ.FT(B# 17016-10000-35504)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11385	17041-10000-33066	10203 S CENTRAL AVE	90002	8	090B209   421	6049026003	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	33.94397	-118.25431	PC T24 ONLY FOR ENERGY FOR (N) ONE-STORY (1493.5 SF) TAKE OUT RESTAURANT (TYPE VB) AT COMMERCIAL CORNER FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD <400A. SCOPE INCLUDES NEW PANELS CIRCUITS EQUIPMENT AND LIGHT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11386	12041-10000-21021	5058 E WILLIAMS PL	90032	14	136-5A235 239	5223007036	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.06814	-118.17455	Plan check for roof mounted 3.2KW photovoltaic system using SunPower transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11387	12041-10001-11785	13429 W VANOWEN ST	91405	2	183B157   950	2328031012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			07/11/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	34.19412	-118.42557	PLAN CHECK ONLY. REVISION TO APPROVED PLANS. CHANGES TO BUILDING FLOOR PLAN LAYOUT. PLAN CHECK FOR POWER AND ENERGFY. NEW 4 STORY 23 UNIT APARTMENT AND A REC. ROOM OVER SUBTERRANEAN GARAGE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11388	17041-20000-07645	7945 N SAUSALITO AVE	91304	12	189B101   330	2013012038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.215	-118.61585	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11389	18041-10001-34521	9034 N BURNET AVE	91343	7	195B145    46	2654006028	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.2348	-118.46302	EXPEDITE PER APPLICANT REQUEST. PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 54.0KWdc / 43.2KWac.(150)MODULES- JINKO SOLAR JKM360M-72-V(75) OPTIMIZERS-SOLAREDGE P730(1)INVERTER-SOLAREDGE SE43.2KUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11390	18041-10000-33984	7411-8041 WORLD WAY WEST Remote-Gates	90045	11	090B157    17	4129026910	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	33.94176	-118.42594	Power plan check for installing (11) electric bus charging stations	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11391	14041-20000-02681	14329 W CARL ST	91331	6	201B153   520	2644024011	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.24716	-118.44537	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.1KW AC USING 24 MICROINVERTER USING STANDARD PLAN. USING ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11392	19041-10001-47424	4124 N CLEAR VALLEY DR	91436	5	165B141   432	2285016017	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.14591	-118.48475	EXPEDITE FEES.NEW ROOFTOP SOLAR INSTALLATION. SYSTEM SIZE 21.12KWdc (17.6KWac). INSTALLING 64 CSH1-330MS MODULES, 64 SE P370 OPTIMEZERS & TWO CENTRAL INVERTERS(SE10000H-US & SE7600H-US). CONNECTED TO A NEW 225Amp SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11393	19041-10001-46110	14312 W BERG ST	91342	7	222B153   398	2508015015	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.30443	-118.44493	0$ FEES PER AB1414PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CHANGE IS REVISING INVERTER SIZE FROM A 3.8 KW SOLAR EDGE INVERTER TO A 5 KW SOLAR EDGE INVETER ALL CHANGES ARE CLOUDED UNDER DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11394	14041-20000-17037	5500 N KLUMP AVE	91601	2	174B173  1273	2350005016	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			06/25/2014 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.17012	-118.37509	Plan check for Power and energy on new 84 units apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11395	19041-20000-11934	817 N VINE ST	90038	13	141B185   248	5533030029	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	06/23/2021 12:00:00 AM	ADDRESS	34.0858	-118.32679	Plan check for power and energy for Tenant Improvement to all 3 floors of office building, load exceed 400A. Total area: 29,006 sq ft. B#19016-10000-07578	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11396	10041-20000-24993	15233 W VENTURA BLVD #PH10	91403	5	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.1538	-118.46502	Plan check T24 Energy (general/emergency) lighting for office TI #PH10 in high rise building. Lighting ckts are existing. Permit for new 3 branch ckts and work on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11397	17041-20001-14082	8900 N CORBIN AVE	91324	12	195B117    43	2783025026	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.23252	-118.56211	Revisions to approved set of plans.  Feeder tap added to accommodate lack of space for a dedicated breaker in panel P5.  Approval for delta-1 revisions only.  (((PLANCHECK FOR POWER.  INSTALLATION OF NEW CAR WASH EQUIPMENT IN AN EXISTING CARWASH.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11398	13041-20000-02294	7855 N HAYVENHURST AVE	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM			PC Approved	01/29/2013 12:00:00 AM	ADDRESS	34.21329	-118.49262	New lighting to an existing commercial space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11399	16041-10000-43764	11909 W OLYMPIC BLVD	90064	11	123B149   504	4259023016	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.03282	-118.45265	T-24, PC for energy only. TI to an existing Restaurant. Scope includes relocating  one existing panel and adding one new subpanel, adding new lights, and new receptacles. Total affected area is sqft = 827.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11400	14041-10000-31975	1000 E CESAR E CHAVEZ AVE	90033	14	130-5A219   6	5410007022	M1-2D-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.0541	-118.22573	Title 24 plan check only.  Total area = 4,315 sq. ft.T.I. to existing warehouse space.  Lighting, recepticles, and 1 new 100A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11401	17041-20000-37663	12940 W ADDISON ST	91423	4	168B161    16	2358023021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.16107	-118.41537	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for solar pv system, roof-mounted array on SFD.Total system size: 15.2kW ungrounded.(2) 7.6kW SolarEdge inverters. (27) 280W pv modules.(26) 300W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11402	17041-20001-43978	18237 W LOS ALIMOS ST	91326	12	207B125   200	2715010021	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.26557	-118.53125	Expedited plan check fee.PV1.  Install 11.05 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (34) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11403	15041-20000-20895	4519 N LENNOX AVE	91423	4	168A151   233	2265016024	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.15359	-118.44556	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 20 MODULES. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11404	18041-20000-04867	20550 W PRAIRIE ST	91311	12	198B109   103	2748041014	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.23919	-118.58098	replace existing metal halide fixture with new led fixtures outdoor.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11405	19041-10000-16508	5411 N ETIWANDA AVE 3RD FLOOR	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Issued	08/23/2019 12:00:00 AM	ADDRESS	34.16935	-118.53104	(Assign to Bishoy) FULL PLAN CHECK PWR AND ENERGY FOR TENANT IMPROVEMENT (21,900 SQFT.) ON THE THIRD FLOOR OF A NEW THREE STORY MEDICAL OFFICE BUILDING. SCOPE INCLUDES INSTALLING NEW PANELS AND HVAC AND PWR CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11406	12041-10000-11468	14520 W GREENLEAF ST	91403	5	165A151    59	2276016004	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.1482	-118.4501	NEW 11.5KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11407	16041-10001-31873	1256 W 7TH ST	90017	1	130-5A205 150	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM			PC Approved	05/30/2017 12:00:00 AM	ADDRESS	34.05216	-118.26774	FIELS REVISIONS DURING CONSTRUCTION: REARRANGE LUMINAIRES;NEW LUMINAIRES AND FC UNITS. ALL CHANGES ARE CLOUDE ON THE PLANS AND DATED 5/26/2017	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11408	19041-30000-23351	11311-11321 W CAMARILLO ST	91602	2	168B173   425	2353023061	C4-1	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Apartment			06/18/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	PIN	34.15793732	-118.3781215	Fire alarm system for 60-unit 5-story apartment building.  FACP, annunciator, and (180) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11409	19041-20000-10321	20734 W BEECH CIR #305	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.29327	-118.58554	INSTALLATION OF A 3.02KW DC/2.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (9) SUNPOWER 335 BLK PV MODULES WITH INTEGRATED MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11410	14041-20000-30504	11001 N FARRALONE AVE	91311	12	210B101    85	2723005028	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			Reviewed by Supervisor	12/05/2014 12:00:00 AM	ADDRESS	34.2695	-118.61055	Ground mounted PV system with point of connection to DWP vault.  Total system is 2.48 MW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11411	14041-20001-06903	9155 N FORBES AVE	91343	12	198B133   496	2687008011	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.23725	-118.50007	(((expedite fees)))pv1 single family dwelling. total system size 6kw ac using transformerless inverter. nonstandard plan. using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11412	19041-20000-01647	2026 W 94TH PL	90047	8	093A191    53	6057015025	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM	01/15/2019 12:00:00 AM		Issued	01/15/2019 12:00:00 AM	ADDRESS	33.95041	-118.31433	Plan check for PV roof mounted system and energy storage,  PV System size: 3.19KW DC, 3.8KW AC, with 11 PV Modules, LG Chem 9.8KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11413	16041-10000-11289	1562 W 49TH ST	90062	8	111B193   957	5016028006	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	33.99903	-118.30551	PV1, INSTALL 2.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(11) MODULES: HYUNDAI HIS-M250MG() INVERTER: ABB PVI-3.0-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11414	16041-20001-10517	19524 W NORDHOFF ST #11	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.23527	-118.55871	7.19.2016 - Plan check for modifications to approved set. Update plan to correctly reflect existing service and panel configuration in tenant space. Change bathroom lighting control from dimmer switch to combined occupancy sensor and dimmer switch.====Plan check for energy only. Change of use from restaurant to music studio. New lighting (incl. emergency). 4,515sqft. Electrical permit pulled under permit #16041-20000-05567	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11415	15041-10005-35073	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	02/28/2017 Changes to an approved set of plans. Changes include relocate exit signs and additional exit signs. Changes has been clouded as delta 38.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11416	17041-10000-11663	633 W 5TH ST #900	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only in existing space office T.I. Total area: 7,655 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11417	18041-20000-07236	1040 N LAS PALMAS AVE	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	Replacement of a medium-voltage transformer and the installation of replacement air-conditioning units and exhaust fans in (E) commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11418	19041-20000-01723	17609 W RAYEN ST	91325	12	195B129   191	2768026016	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	03/09/2019 12:00:00 AM	ADDRESS	34.23234	-118.51803	PV1.  Install11.880 kW DC / 11.095 kW CEC-AC roof mounted grid tied PV system.  (36) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11419	10041-20000-23535	333 S HOPE ST 29th and-30th floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/18/2011 12:00:00 AM		Permit Finaled	03/14/2011 12:00:00 AM	ADDRESS	34.05326	-118.25292	Install general lightin in existing high rise building on 29th floor (recreation room) and 30th floor (shower room).  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11420	19041-10000-08371	355 S GRAND AVE SUITE 3120	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM			PC Info Complete	03/08/2019 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR TENANT IMPROVEMENT TO EXISTING OFFICE SPACE ON 31TH FLOOR (NO CHANGE OF USE) INCLUDIN NEW NON STRUCTURAL PARTITION - TOTAL AFFECTED AREA = 2400 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11421	19041-10000-18465	10567 W CUSHDON AVE	90064	5	126B157   731	4318007020	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.0415	-118.42011	[e-plan] PV1. Install new roof mounted Solar system with 1 Inverter, 17 Modules & 1 Energy Storage System @13.5KWH. Scope includes two new  200A Load Centers. System Siza is 5.61KWdc & 5KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11422	14041-10002-06676	12855 W RUNWAY ROAD block 1	90094	11	102B157   395	4211033054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Public Safety Only			01/28/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	33.97556	-118.41956	**Revision to an approved set, adding 14 devices and changing Horn model type.(((*Revision to an approved set with adding # of devices less than 10.<<<New fire alarm system. block 1. playa vista.>>)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11423	16041-20000-25960	1255 N BUNDY DR	90049	11	141B141   159	4493028021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.08224	-118.48357	Plan check for PV roof mounted system. System size: 11.7kW with 41 modules and 41 microinverters(Enphase)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11424	17041-10000-07303	7600 W MELROSE AVE Suite A	90046	5	141B177   649	5526015028	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Issued	03/07/2017 12:00:00 AM	ADDRESS	34.08354	-118.35553	Plan check for Title 24 only in existing space change to use from massage parlor to nail salon. Total area: 919 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11425	18041-10000-16962	9825 N MASON AVE	91311	12	201B109   143	2748005021	(T)(Q)CM-1L, (T)(Q)CM-1LD, (T)(Q)M1-1, (T)(Q)M1-1D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	04/09/2020 12:00:00 AM	ADDRESS	34.24844	-118.58019	PC FOR POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO GYM FOR A FIRST TIME TENANT TOTAL CONNECTED LOAD >400A SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 19201B# 18016-70000-13172	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11426	18041-20000-07144	2783-2801 W FRANCIS AVE	90005	1	132A201    90	5077021029	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	01/12/2022 12:00:00 AM	ADDRESS	34.05694	-118.28632	new fire alarm system 144 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11427	13041-10000-13249	590 N VERMONT AVE 1ST & 3RD-FLOOR	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	PLAN CHECK FOR TI TO EXISTING 6-STORY BUILDING. PT-PHYSICAL THERAPY UNIVERSITY CLASSROOMS & OFFICE ON 1ST AND 3RD FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11428	14041-20000-32974	920 W BLOOM WALK	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM			PC Approved	11/25/2014 12:00:00 AM	ADDRESS	34.01996	-118.28938	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR A SINGLE OFFICE IN USC SEAVER SCIENCE CENTER. 171 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11429	11041-20000-21324	601 S FIGUEROA ST 36TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check T24 Energy/emergency lighting for existing corridor on 36th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11430	16041-10000-33191	2138 N HILLHURST AVE	90027	4	150B201    98	5590001024	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.11116	-118.28727	shell and core improvement for an  existing building with proposed 2 tenant spacesNote that tenant panelboards are to be installed and future tenants will develope their tenant spacesSee 16016-10000-13956	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11431	14041-20000-05307	19417 W ARCHWOOD ST	91335	3	180B117   193	2131004025	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.19234	-118.55639	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11432	14041-10001-02442	1102 S WESTERN AVE	90006	10	129B193   647	5080010001	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.05064	-118.30888	Changes to approved plan set - change of source of emergency egress lighting (emergency ballast to bugeye fixtures).  (((T24 PART 6 ENERGY PLAN CHECK FOR COFFEE SHOP. PROJECTED IN LIGHTING SCOPE OF WORK IS APPROX. 1349 SQ FT AREA. SCOPE OF WORK < 400A. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER. ALL WORK WILL BE INTERIOR,  PER APPLICANT.note: permit fee already calculated under inspection fee period)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11433	15041-20000-38189	15363 W DEL GADO DR	91403	4	165A145    71	2281005014	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	01/02/2016 12:00:00 AM	ADDRESS	34.14764	-118.46904	PV1, roof mounted solar system, total system size is 6.24kWdc/6.00KWac system. Standard plan is being used. (24)modules #KU2656ZPA, (1)inverter:PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11434	17041-10000-39431	1001 W KNOX ST	90502	15	057B197    18	7351031017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	33.85434	-118.29392	PC FOR SERVICE UPGRADE FROM 800 TO 1600A ,480/277 V, 3PH, 4W. TOTAL AFFECTED AREA 320SQ.FT. (only electrical room under T24 SOW plan check). Load  under this SOW only covers lighting and receptacle inside the electrical room. B# 17016-10000-31850	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11435	10041-10001-22406	1360 S WESTWOOD BLVD	90024	5	132B153   766	4325016015	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	34.05594	-118.44192	MODIFICATION TO PREVIOUSLY APPROVED PLANS (AS-BUILT).  ALL CHANGES ARE CLOUDED AND LISTED ON THE REVISION SHEETS ATTACHED.     <<<<TENANT IMPROVEMENT OF EXISTING RETAIL BUILDING-NEW ROSS DEPARTMENT STORE>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11436	15041-10001-28233	6614 W MELROSE AVE	90036	5	141B185   610	5524017002	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	PIN	34.08319313	-118.33922028	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<pv2, install 9.405 kw dc roof-mounted solar array on a commercial building. (33) micronverter: enphase energy M250-60-2LL(33) MODULES: SOLAR WORLD SW 285 MONO>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11437	16041-20000-21115	2941 W PICO BLVD	90006	10	129B193  1242	5080020027	[Q]C2-2	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.04736	-118.30448	Plan check for a PV2 roof-mounted PV system. System size is 60 kWac and consists of (4) inverter, (216) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11438	10041-20000-06082	19950 W RINALDI ST	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM			PC Approved	04/05/2010 12:00:00 AM	ADDRESS	34.27535	-118.56939	change location of 2 panels and transformer from approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11439	10041-10000-16421	2049 S CENTURY PARK EAST 25th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	11/06/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI in the elevator lobby of the 25th floor. Plan Check is for T-24 energy calcs and emergency light.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11440	16041-20003-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			12/10/2018 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	12/10/2018changes to an approved set of plans.  changes to reconfigure level 1 core and shell floor plan to five future retail spaces.  all changes noted delta 12. under construction, see notes. this is plan check only.  ((((SEE APPLICATION NOTES***********PC FOR  CHANGES TO APPROVED SET UNDER DELTA 7 & 9 .SCOPE INCLUDES CHANGES TO LIGHTS  AND T-24 IN ALL FLOORS. ADDITIONAL AREA HAS BEEN ADDED FOR AROUND 3000SQ.FT FROM LAST APPROVED SET.))))  (((FULL PC FOR POWER AND ENERGY  FOR A NEW 7 STORY MIXED USE BLDG.:  169 UNIT APARTMENT WITH RETAIL AND PARKING. SCOPE INCLUDES A NEW 4000A 277/480V 3 PHASE, 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. THERE ARE 11 TYPES OF APARTMENT UNIT PANELS. TOTAL AFFECTED AREA IS 160530 SQ. FT. B#16010-10000-03070Fire alarm modification was filed with the department 4/5/2017.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11441	16041-10000-44030	10250 W SANTA MONICA BLVD #1905	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check power and energy for 1st time tenant Caudalie Space #1905 installed 30KVA transformer and 100A MCB, 120/208 panel and 60A MCB 480/277. Total area: 907 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11442	15041-20001-24451	2800 VIA CABRILLO MARINA	90731	15	009B197  1289	7440040906	PF-1XL	Harbor	San Pedro	Coastal San Pedro		2976.01	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	PIN	33.71792061	-118.28760715	Changes to approved set.  Addition of emergency lighting to one room (existing general lighting to remain) and changing general lighting in one space from new to future.PC AT COUNTER FOR ENERGY ONLY, T-24. SMALL RENOVATION FOR A (3) STORY HOTEL.SCOPE OF WORK INCLUDES NEW LIGHTING FOR RECEPTION, GIFT SHOP, LOBBY, WAITING AREA, FOYER, PARTY ROOM, AND BUFFET AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11443	14041-20000-15355	7506 W SUMMITROSE ST	91042	7	204B197   133	2558014002	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.25947	-118.29529	PV1Central Transformerless Inverter Standard PlanInstall roof-mounted solar array on SFD. System size: 4.2kW(1) Power-One PVI-4.2-OUTD-S-US-A transformerless inverter(22) Renesola Jinagsu: JC255M-24/BXH pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11444	10041-20002-25715	4600 W SPERRY ST	90039	4	165B201   177	5593007004	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.14823	-118.27596	Changes from previously plans.  Changes include replace microinverter with M215 model. *****New roof mounted 10.5 kw AC module P.V. system for commercial building. *****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11445	19041-10000-10050	912 S HILL ST	90015	14	127-5A209 209	5139003001	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM			Reviewed by Supervisor	06/06/2019 12:00:00 AM	ADDRESS	34.04255	-118.25729	POWER AND ENERGY PLAN CHECK FOR A COMPLETE SHELL AND CORE RENEVATION TO A 6 FLOOR PARKING GARAGE. ADDITION OF CORE RETAIL SPACES ON GROUND FLOOR AND 3 LEVELS OF OFFICE CORE ON LVL 5, 6 AND 7.  DETAILED SCOPE OF WORK UNDER THE BUILDING PERMIT. SCOPE INCLUDE 2 NEW 1200A SERVICES AND EQUIPMENT. FULLY NEW ELECTRICAL SYSTEM. B#18014-10000-00179	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11446	17041-20000-36318	2204 N MARAVILLA DR	90068	4	150B181   118	5549013026	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.11013	-118.34326	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (1) battery backup system to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11447	18041-20000-48464	889 S FRANCISCO ST NA	90017	14	129A207   342	5144023***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	04/24/2019 12:00:00 AM		Issued	04/24/2019 12:00:00 AM	ADDRESS	34.04769	-118.26404	Plan check for first time tenant at ground level sales room. Total area: 1305sq ft.B#18016-10000-40459	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11448	15041-10000-36810	11931 W GOSHEN AVE 1-9	90049	11	129B145   830	4265012047	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.04726	-118.46571	NEW FIRE ALARM SYSTEM TO A 9 UNIT APARTMENT. 1 FIRE ALARM PANEL AND 49 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11449	18041-10000-39800	777 S FIGUEROA ST 39TH FLOOR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	PLAN CHECK FOR T24 ONLY, INTERIOR REMODEL AND TENANT IMPROVEMENT OF (E) OFFICE BUILDING. REPURSPOSE LOAD ON EXISTING BRANCH CIRCUIT. TOTAL AREA: 1,397 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11450	17041-10000-17501	10250 W SANTA MONICA BLVD # FC-10	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan Check. At food court, Spice Affair restaurant installing new kitchen equipment and luminaires.  Service is existing for this tenant.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11451	12041-10000-12827	4263 N VIA ARBOLADA	90042	14	147A229    76	5302009***	[Q]RD6-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	2013.02	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.09715	-118.18836	Plan check 6.615KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11452	13041-20004-03947	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.0346	-118.45665	changes to approved set of plans. changes to site lighting. t24 only. pc only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11453	19041-10000-22462	1601 S VICTORIA AVE	90019	10	126B185   134	5071004001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.04485	-118.32987	(ePlan) $0 fee due to AB1414. Revision to approved set to add 2nd AC Disconnect on ESS per utility request (PV is existing).  All other information remain the same.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11454	12041-20000-20023	14006 W RIVERSIDE DR 124	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM			PC Approved	09/05/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24 lighting plan check for CHANGE OF USE FROM (E)RESTAURANT TO NEW HAIR SALON.(NO CHANGE IN PARKING)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11455	16041-10000-09201	6600 N TOPANGA CANYON BLVD #1017	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI TO AN EXISTING COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISITNG PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2603.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11456	11041-10002-10859	6725 W SUNSET BLVD 5th Floor	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.09814	-118.33717	TI TO AN EXISTING 5-STORY OFFICE BUILDING.  T-24 WITH EMERGENCY, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11457	16041-20000-00732	19812 W LULL ST	91306	3	186B113   152	2106033040	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.20908	-118.56483	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11458	15041-10001-22477	11445 N PETIT AVE	91344	12	213B133   760	2682005011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	PIN	34.27863511	-118.49898739	PV1.  Install 7.5 kW DC roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11459	14041-20000-09939	9301 N TAMPA AVE 70B & 69D	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI in an existing Jewelry Store. # 70B & 69D. Title 24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11460	18041-20000-48103	2221 W BEVERLY BLVD 1st flr	90057	13	136-5A205 262	5157018058	C2-1	Central	Westlake	Echo Park		2085.01	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	34.06759	-118.27198	ti to an existing commercial building.  adding new lighting new control to existing panel.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11461	16041-10000-38467	20445 W ESMERELDA LANE	91326	12	216B109   263	2701082078	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.29108	-118.5797	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.475KWdc / 11.76KWac.(49)MODULES-CANADIAN SOLAR CS6K-275M(49)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11462	19041-20001-23757	9413 N BURNET AVE	91343	7	198B145   442	2656019***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM			PC Approved	07/26/2019 12:00:00 AM	ADDRESS	34.24126	-118.46341	PLAN CHECK ONLY, CHANGES TO APPROVED SET, REMOVING 5 TOTAL MODULES AND CHANGING MODULE MODEL FROM LONGI TO HANWHA Q CELLS. TOTAL SYSTEM SIZE IS NOW 10.08KW DC/9KW AC. CHANGES MADE TO ALL PAGES. CLOUDED DELTA B CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11463	16041-10000-43123	6641 W SANTA MONICA BLVD	90038	4	144B185   654	5532022023	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.09088	-118.33439	PC for energy only. Replace inoddr HID fixture with new LED fixture. Total area: 12,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11464	11041-10000-20329	1700 W 25TH ST	90732	15	012B189   612	7562005013	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	33.72418	-118.31493	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11465	10041-20000-11060	10673 W PICO BLVD	90064	5	126B157   590	4320008043	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.04238	-118.42423	Plan check power and energy for change of use from retail to dental office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11466	15041-20000-27191	350 S GRAND AVE SUITE 3550	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	PIN	34.05160512	-118.25169569	TI to existing high rise commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 775.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11467	19041-10000-06773	6600 N TOPANGA CANYON BLVD SPC 40	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC T-24 ONLY , TI TO ADD STORAGE ROOM TO EXISTING TENANT SPACE. NO CHANGE OF USE. AREA OF SCOPE 259SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11468	19041-20000-12225	16633 W VENTURA BLVD #1400	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.15823	-118.49571	Office TI and expansion in commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11469	11041-10000-22384	809 S ARDMORE AVE	90005	10	132B193   636	5093024025	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2124.20	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM			PC Approved	10/19/2011 12:00:00 AM	ADDRESS	34.05745	-118.30211	TENANT IMPROVEMENT IN A RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11470	12041-10001-20558	3162 N DONA CRISTINA PL	91604	2	156B169    54	2381008021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.12783	-118.38281	CHANGES TO APRROVED SET OF PV1 STANDARD PLANS UNDER PLAN CHECK NUMBER 12041-10000-20558. MOUDLE TYPE CHANGED TO KYOCERA 215 AND TOTAL NUMBER INCREASED BY THREE. SYSTEM SIZE DECREASED FROM 7.92KW TO 7.74KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11471	13041-20000-18880	19320 W NORDHOFF ST	91324	12	198B117   230	2783028057	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.23529	-118.55444	FULL PLAN CHECK FOR POWER AND ENERGY FOR TI TO EXISTING RETAIL SPACE, CHANGING INTO PETSMART. SERVICE SIZE 800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11472	14041-20000-12469	961 N ST ANDREWS PL	90038	13	144B193  1190	5535005023	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.08792	-118.31161	PV1. 3.825kw roof-mounted system with with (15) Solarworld 255w modules and (15) Enphase Microinverters(M215-60-240S22).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11473	16041-10000-15398	4415 N DULCINEA CT	91364	3	165B101   255	2173014010	RE15-1-RPD-2.9-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.14854	-118.60681	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.25KWdc / 7.6KWac.(30)MODULES-MITSUBISHI PV-MLE275HD2(30)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE7600A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11474	19041-30001-14694	10940 W WILSHIRE BLVD #1800	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	ADDRESS	34.05822	-118.4452	Plan check for Title 24 only. Project site is a suite on the 18th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,077 sq. ft.Note: Building permit has been issued under 19016-40000-09386*****Original Work Description*****EXISTING BRANCH CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11475	17041-10000-05586	10384-10428 N SEPULVEDA BLVD	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.25921	-118.46706	NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 35 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11476	15041-20000-04091	333 S HOPE ST 54TH FLOOR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	TI TO OFFICES ON 54TH FLOOR. PC FOR T24 ENERGY ONLY. NEW LIGHITNG IN SMALL OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11477	15041-10000-39574	701 E 3RD ST 4TH FLR	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	PIN	34.04581508	-118.23784015	Energy plan check for an office T.I. located in the 4th floor of a commerical building ; Scope includes new lighting and receptacles, total area is 11,356 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11478	17041-10000-04413	9490 W CHEROKEE LANE	90210	4	150B165    96	4387032012	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.11025	-118.4021	PC FOR PV ROOF MOUNTED SYSTEM USING MICROINVERTER SYSTEM - TOTAL OF 22 MODULES AND RATED 5.2KW AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11479	17041-20000-35802	4219 N SHADYGLADE AVE	91604	2	165B165   887	2367007016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.14734	-118.40202	install (2) tesla powerwalls 5kw each.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11480	18041-20000-24430	9821 N FARRALONE AVE	91311	12	201B101   204	2727005023	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.2489	-118.61066	pv1install roof mounted pv system sized 5kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11481	18041-20000-02796	4820 S ALLA ROAD	90066	11	105B157   536	4223008005	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	33.98277	-118.42936	Permit 1 of 3 for (3) new 2-story core and shell commercial office buildings.  New 5000A 480Y/277V 3ph-4w service and building 1 distribution equipment/loads.  Plan check for power and energy.  Bldg permits for the (3) separate buildings are under the following permits:16010-10000-0393516010-10000-0393616010-10000-03937	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11482	15041-20000-15155	301 N CAROLWOOD DR	90077	5	141B157    34	4358005017	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.08337	-118.42821	Plan check for power for a single family dwelling. Project site is a new home. Project scope includes the installation of a new 1000-amp service,  (11) panels, and associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11483	19041-20001-24206	4335 W CEDARHURST CIR pv1	90027	4	150B201    80	5591007007	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM			PC Approved	08/06/2019 12:00:00 AM	ADDRESS	34.11121	-118.28435	expeditepv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11484	17041-10000-06294	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.03145	-118.41085	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  102083 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11485	12041-10000-03940	705 N FRONT ST	90731	15	021B201    94	7448035***	M1-1VL	Harbor	San Pedro	Central San Pedro	YES	2962.10	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.75081	-118.28229	New 600A service and equipment for Port of LA Inspection Facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11486	11041-20000-03902	1021 W CHILDS WAY Dedeaux-Field	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Finaled	04/06/2011 12:00:00 AM	ADDRESS	34.02281	-118.29046	Plan check power for new USC Baseball Field lighting replacement. Installation in unclassified area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11487	12041-20001-30129	6420 W WILSHIRE BLVD 5TH FLR	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM			PC Approved	01/31/2013 12:00:00 AM	ADDRESS	34.06365	-118.36922	Change to lighting.  Load is less than 400 amps per applicant, if load for this project on this floor, including other floors, exceeds 400 amps, full plan check will be required.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11488	13041-20000-26302	5520 W RED OAK DR	90068	4	153B193   310	5587004007	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.11291	-118.31028	New Rooftop PV system for an existing single family residence.  Submitted per applicant's request.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11489	14041-20000-01368	1902 W 65TH ST	90047	8	105B193  1435	6016009015	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	33.98051	-118.31138	New rooftop mounted PV system for an existing single family dwelling.  System is UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11490	19041-20000-21405	19372 W CITRONIA ST	91324	12	201B117   587	2761006013	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.24454	-118.55576	Plan check for a PV1 roof-mounted PV system. System size is 12.8 kWdc/10.88 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (40) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11491	14041-10000-35773	1969 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.06159	-118.20463	SRH LOBBY REMODELPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11492	18041-10001-19377	3129 S EARLMAR DR	90064	5	123B165   376	4316009013	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM			PC Approved	06/04/2018 12:00:00 AM	ADDRESS	34.03486	-118.40559	**expedited fee per applicant**New rooftop solar system, 10.4 kW AC/ 10.725 kW DC. (33) modules, (2) 5.2 kW inverters, (1) 125A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11493	16041-20003-16440	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	"(3/30/17)changes to an approved set of plans.  changes include the addition of exit signs to all floors except floor 3and 4.  changes noted delta 27. this is plan check only.(2/16/2017)changes to an approved set of plans.  Changes noted ""note 23"" Change from fully rated to series rating to reflect existing conditions.  See attached short circuit load study.  This is plan check only.(12/16/2016)CHANGES TO AN APPROVED SET OF PLANS TO REFLCT FIELD CONDITIONS, CHANGES NOTED UNDER DELTA 20.THIS IS PLAN CHECK ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11494	15041-10000-20181	14950 W INDEX ST	91345	7	213B149   821	2664025029	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.27672	-118.45804	PVI, INSTALL 4.905 KW DC ROOF--MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(15) MODULES: SUNPOWER SPR327NE-WHT(1) INVERTERS: POWER ONE PVI-4.2 OUTD-US-S	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11495	18041-10000-08659	319 E 2ND ST #116	90012	14	129A213    10	5161017034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.04929	-118.24098	PC FOR T-24 ONLY.  TOTAL AFFECTED AREA IS 490 SQ.FT. B# 18016-10000-00283	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11496	15041-10003-17786	11675 N GLENOAKS BLVD	91331	7	213B157   218	2524022003	C2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM			Reviewed by Supervisor	05/27/2016 12:00:00 AM	ADDRESS	34.2823	-118.42116	$0 FEE DEPARTMENTAL ERRORTHIS APPLICATION IS FOR EXPEDITE AND GENERATE NEW PLAN CHECK NUMBER FOR DEPT ERROR SET OF PLANS. ALL PERMIT ITEMS AND PLAN CHECK FEES HAVE BEEN PAID UNDER APPLICATION NUMBER 15041-10002-17786. THIS APPLICATION TO BE ASSIGNED TO MEHDI. TIME CHARGED EQUAL TO 10 STANDARD HOURS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11497	10041-20000-16030	1302 N COLLINGWOOD PL	90069	5	144B169    73	5560003011	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2010 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.09467	-118.38339	New single family dwelling with new service, switchboard, panels, and branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11498	19041-20000-25329	17173 W BRAXTON ST	91344	12	222B133   682	2608004020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.30105	-118.50718	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS  11.22 KW DC/9.99KW CEC AC. SCOPE OF WORK INCLUDES (34) PANASONIC PV MODULES, WITH ENPHASE IQ7X MICROINVERTERS AND A ENPHASE COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11499	19041-20000-53532	408 N BOWLING GREEN WAY	90049	11	135B141   499	4402018019	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.06568	-118.47747	Plan check for PV roof mounted system, PV system size: 14.07KW with 42 PV Modules  and 2 inverters(7.6KW and 5.0)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11500	11041-10000-10035	1526 N EDGEMONT ST	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	09/19/2011 12:00:00 AM	ADDRESS	34.09898	-118.29599	Provid power for new UPS for local area network upgrade. New Xfmr, receptacles, and panel boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11501	11041-10001-20651	1006-1012 E ELKGROVE AVE BLDG 6	90291	11	111B145   749	4243002067	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.00013	-118.45947	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11502	16041-10011-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	PIN	34.2363795	-118.55851216	PC ONLY. Delta 34 changes only to an approved set. Removing lights in closet area (Typical) and adding a water proof receptacle on the balcony when required.Original scope:((( PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE 214 UNITAPARTMENT WITH RETAIL CORE & SHELL. 4 FLOORS OF RESIDENTIAL OVER 2 FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL.  THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMPS, 4000 AMPS, AND 1000 AMPS.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11503	10041-10001-23139	1166 S SOTO ST	90023	14	121-5A221  24	5170005026	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2047.00	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM			PC Info Complete	01/27/2011 12:00:00 AM	ADDRESS	34.02828	-118.2191	Change the priviously approved plan. Addition of a new Gutter, panel and branch circuits. EPC is for power. All the changes are showen by delta 3& 4. (((((((((((((((((UPGRADE AN EXISTING CAR WASH IN AN EXISTING GAS STATION. INSTALL A NEW 600 AMP SERVICE.))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11504	11041-10000-17309	114 N GAFFEY ST	90731	15	018B197  1128	7451006030	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	33.74356	-118.2921	T.I.  Existing 7-Eleven.  Replacing the exsiting light fixtures with LED fixtures in the retail area only.  PLan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11505	13041-20001-23238	616 N LA JOLLA AVE	90048	5	141B173   733	5528011014	R1-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM			PC Approved	08/31/2013 12:00:00 AM	ADDRESS	34.08205	-118.36785	EXPEDITE FEES<<<New rooftop PV System on an existing 2-unit residential building.  System uses Enphase Microinverters.  Plan check is only for PV system, NOT for service upgrade or de-rating of main breaker.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11506	14041-20000-04970	7307 N BALCOM AVE	91335	3	186B129  1134	2121011018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.20329	-118.5209	Roof mounted PV system with Optimizer, system size is 3.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11507	11041-20000-27235	1955 E CESAR E CHAVEZ AVE	90033	14	129A223    31	5175033028	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.04948	-118.21341	Remodeled coin laundry.  add a new 200A panel and lighting.  Existing service and all panels and branch circuits are existing and to be remained.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11508	17041-20000-06991	16661 W CUMBRE VERDE CT	90272	11	138B121   197	4431033021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.07106	-118.55112	"""0$ permit fees due to senate bill 1222 ""Plan check for a PV1 roof-mounted PV system. System size is 12.6 kWac and consists of (2) inverters, (54) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11509	14041-20000-00499	7625 N KELVIN AVE	91306	3	186B109   160	2108033009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Expired	02/25/2016 12:00:00 AM	ADDRESS	34.20902	-118.58643	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11510	15041-10002-19615	2968 W 6TH ST	90005	10	135A201   140	5077007001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	PIN	34.06352386	-118.28606577	delta 27 revisions: new panel and circuits;revised AIC rating of panels to correspond with coordination study; with nochanges to loads, revised ampere rating of RDAB,RDAA,RDBB;RDBA(((((((FULL PC REQ., NEW APARTEMENT BLD. 6 LEVELS, 396 UNITS, OVER 3 LVL OF TYPE 1 PARKING STRUCTURE.52,748 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11511	13041-10000-30392	2250 N TRACY TER	90027	4	148-5A205 160	5433017006	[Q]C1-1XL	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.10195	-118.27352	changes to expired plans (but permit not expired yet under application 12041-10000-01364 - mt12/2/2013). addition of a subpanel on the ground level.PV1 5.04KWAC. 240V. microinverter. NONstd. 3story. Roofmount. [(21) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(21)modules: {SHARP 240W ND-240QCJ}] SYSTEM SIZE IS 4.515 KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11512	14041-10000-26981	6516 N AGNES AVE	91606	2	180B165   535	2322008061	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Expired	10/25/2016 12:00:00 AM	ADDRESS	34.18912	-118.39526	INSTALLATION OF NEW ROOF MOUNTED SOLAR PV ARRAY.  Total system size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11513	13041-10000-05172	612 S FLOWER ST	90017	14	129A209   264	5144005124	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			Corrections Issued	02/28/2013 12:00:00 AM	ADDRESS	34.0497	-118.25759	TI OF EXISTING ATM SPACE. AREA USED FOR FINIANCIAL TRANSACTIONS. TOTAL AREA 100 SQ FT. PC FOR ENERGY ONLY, T24. PERMIT ALREADY ISSUED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11514	11041-20000-26999	11950 W VOSE ST	91605	6	183B165   205	2321008008	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	05/25/2012 12:00:00 AM	ADDRESS	34.19833	-118.39366	Tenant improvement.  Existing commercial building.  New 1600 amp service, new panels, new ckts.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11515	16041-10000-06463	7880 N VAN NUYS BLVD	91402	6	189B149   638	2212028014	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.21541	-118.4462	PC FOR ENERGY T24 ONLY TO A  CLOTHING STORE. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL AREA 8875 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11516	14041-20000-06847	5809 N MELVIN AVE	91356	3	174B117    77	2153024035	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.17627	-118.56022	PV1 TRANSFORMERLESS SYSTEM. 38 MODULES AND 2 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11517	16041-10000-26009	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.0365	-118.3687	CHANGE OF USE TO AUTO SERVICE CENTER. PC FOR POWER AND ENERGY. CONNECTING TO EXISTING 800. LOAD GREATER THAN 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11518	16041-20002-25568	7722 N FAUST AVE	91304	12	189B097  1093	2013031021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM			PC Approved	12/09/2016 12:00:00 AM	ADDRESS	34.21069	-118.62032	"[[[ CHANGES TO APPROVED SET.  PLANCHECK ONLY. DELTA D CHANGES ONLY.  CHANGES ARE CLOUDED. ]]]""$0 permit fees due to senate bill 1222 ""PV1. ROOFMOUNTED SOLAR SYSTEM.  A NEW PV SYSTEM WITH BATTERY BACKUP.  SUNVERGE SIS 6848 . SYSTEM SIZE: 8.8KW."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11519	12041-10000-13948	2100 E 14TH ST	90021	14	120A215    60	5167016029	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM			PC Approved	06/15/2012 12:00:00 AM	ADDRESS	34.02436	-118.23551	"CONSTRUCTION OF NEW BLOCK WALL BUILDING WITH OFFICE & WAREHOUSING 4,861 S.F.  Load is less than 400A.  Plan check only for Energy, with Emergency lighting.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11520	16041-20000-44593	7324 N OWENSMOUTH AVE	91303	3	186B105   769	2111014008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Issued	01/12/2017 12:00:00 AM	ADDRESS	34.20358	-118.60141	PV1.  Install 3.5 kW roof mounted, grid tied PV system on SFD main house and detached garage.  (11) modules with Enphase M250 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11521	13041-10000-31707	2027 S STONER AVE	90025	11	123B149   274	4262032901	PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.03582	-118.4508	PLAN CHECK FOR GAS MONITORING SYSTEM FOR EXISTING TRUCK/SWEEPER MAINTENANCE FACILITY LGC/CNG.NOTE: ELECTRICAL PLAN SUBMITTED SEPARATELY UNDER 13041-10000-31705	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11522	17041-10000-03998	4062 S MANTOVA DR	90008	10	114B177   117	5029037010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.01101	-118.36008	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.4KWac.(30)MODULES-LG LG315N1C-Z4(2)INVERTERS-SOLIVIA 5.2 TL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11523	15041-20000-02595	8758 S DENKER AVE	90047	8	096A195   190	6037012006	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	33.95722	-118.30451	pv1. roofmounted solar system. system size: 3.8 kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11524	11041-10000-10780	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	33.93195	-118.41136	BRAND NEW FIRE ALARM FOR AN EXISTING 2-STORY COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11525	16041-10001-00463	4051 S BROADWAY	90037	9	115-5A203 216	5111004008	M1-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.00995	-118.27859	PLAN CHECK FOR POWER ALREADY ISSUED. THIS IS PLAN CHECK FOR 600A SERVICE AND FOR FUTURE USE OF BUILDING. RECONNECTING EXISTING LOADS. plan check for system and permit under this application for 600A addition to scope of work	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11526	19041-10000-07318	1609 W 25TH ST	90732	15	009B189   138	7563016018	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	33.72309	-118.31342	Plan check for T24 only, tenant improvement for change of use from retail to Chiropractor office. (No medical exam rooms. Full plan check may be required subject to field inspection).  New lights and power are fed from existing subpanel in the area. Total affected area is  1,475 sq.ft(B# 19016-40000-04266)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11527	12041-10000-18354	141 W ADAMS BLVD	90007	9	121-5A205 228	5126036010	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.02564	-118.26997	Plan check for new roof mounted 10.78KW photovoltaic system. Existing Wells Fargo Bank.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11528	18041-10000-31091	4640 N LANKERSHIM BLVD 2nd,5th,-and 6th	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.15499	-118.36841	PLAN CHECK FOR POWERT AND ENERGY FOR - INTERIOR T.I. OF RESTROOM REMODEL FOR FLOORS 2, 5, AND 6 IN (E) OFFICE BUILDING TO BE ADA COMPLIANT. NO CHANGE IN FIRE LIFE SAFETY. - TOTAL AFFECTED AREA = 1044 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11529	16041-20000-31346	555 S FLOWER ST Ste 3420	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI to (E) commercial office space in a commercial highrise building.  Plan check for energy.  8024 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11530	14041-20000-14264	1632 S ABBOT KINNEY BLVD	90291	11	108B145  1657	4238017029	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	33.98951	-118.46337	New single family dwelling with 400A service.  Plan check for power onnly	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11531	17041-10000-06377	11651-11665 W SANTA MONICA BLVD	90025	11	126B149   198	4262002014	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Issued	06/15/2017 12:00:00 AM	ADDRESS	34.04432	-118.45525	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES ADDING NEW OUTDOOR LIGHTS. TOTAL AFFECTED AREA IS 6372 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11532	08041-10001-18784	4433 S ALAMEDA ST	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			Corrections Issued	05/09/2011 12:00:00 AM	ADDRESS	34.00295	-118.23924	"T-24 Plan check general lighting for a kitchen in an existing restaurant (""LA REYNA"").  ( Originally, plan was designed by different engineer.)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11533	14041-20001-17525	4537 N TENANGO DR	91364	3	165B113    16	2174025023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.15235	-118.57355	Expedited plan check per applicant request.  PV1.  Install 13.52 kW roof-mounted, utility-interactive PV system.  (2) transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11534	19041-20000-28090	5315 N WILKINSON AVE	91607	2	171B165   226	2347031***	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.16718	-118.4043	addition of (1) tesla ESS to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11535	16041-10001-29245	9111 N CORBIN AVE	91324	12	198B117   206	2761001074	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.23591	-118.56269	CHNGES TO APPROVED SET OF PLANS. SCOPE INCLUDES CHANGE AND RELOCATION OF MAIN DISTRIBUTION EQUIPMENT, ELEVATOR LOADS UPGRADES AND ASSOCIATED EQUIPMENT, REVISED LOAD CALCULATIONS & ADDED RECEPTACLE LOADS. IRIGINAL PERMIT 16041-10000-29245--------Full Plan check. Change of use for existing two story bank building to an outpatient medical clinic. Service is being upgraded from 800 amps to 1200 A 3phase 4wire 120/208V. Adding new lighting and power. Total sqft = 16,679.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11536	19041-20000-05322	2701 N GLENDOWER AVE	90027	4	153B197   104	5588020030	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.11628	-118.29464	INSTALLING 1 NEW TESLA POWERWALL ON EXISTING PV SCOPE OF WORK INCLUDES ADDING 100A NEW GENERATION SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11537	13041-20000-09793	6310 W SAN VICENTE BLVD	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.06084	-118.36757	ENERGY PLAN CHECK OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11538	18041-10000-05749	10250 W SANTA MONICA BLVD #1305 &-1030	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check  for first time tenant "" 85 degree C Bakery Cafe""  Ste.# 1305&1030 in Westfiled century City. Install (4) new panels, (2) 30kVA transformers, new lightings and powers. Total area: 2021 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11539	17041-20000-16269	3601 S FLOWER ST	90007	9	118-5A201  65	5037029018	USC-1B	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	05/16/2017 12:00:00 AM	ADDRESS	34.01817	-118.28097	TI to (E) commercial office space.  Plan check for energy.  2,444 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11540	13041-10000-09378	13622 W CHASE ST	91331	4, 6	195B157   512	2640029014	R1-1	Central, North Valley	Arleta - Pacoima, Hollywood	Arleta, Hollywood United	YES	1198.00, 1894.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Expired	05/06/2015 12:00:00 AM	ADDRESS	34.23138	-118.42888	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A 1 STORY SINGLE FAMILY DWELLING. SYSTEM SIZE IS 1.9 KW USING 9 MICROINVERTERS. [INVERTERS: ENPHASE ENERGY # M215-60-2LL-S22 |||| MODULES: HANWA SOLAR # HSL60P6-PA-0-240-T]. FIRE DEPARTMENT HAS STAMPED A NON STANDARD ROOF PLAN DATED 4/11/13.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11541	15041-10000-24503	5901 W CENTER DR	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			08/06/2015 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	33.97509	-118.38703	(N) 280 UNIT + 1 MODEL UNIT RENTAL APARTMENT BUILDING CONSITING OF 5 STORIES OF TYPE V CONSTRUCTION APARTMENTS, 2 STORIES OF CONCRETE CONSTRUCTION PARKING & COMMON USES ABOVE.  1 LEVEL OF SUBTERRANEAN PARKING.  4000 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.T-24 TO BE SUBMITTED NEXT WEEK 8/10/15.FIRE ALARM VARIANCE TO BE FILED AT A LATER TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11542	18041-10000-32768	1447 N NAUD ST	90012	1	136-5A217  70	5409004015	UV(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.06658	-118.2312	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11543	14041-10000-01975	12455 N SAN FERNANDO ROAD	91342	7	219B149   497	2611001008	(T)(Q)RAS3-1VL	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Public Safety Only			01/23/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.29675	-118.45633	NEW FIRE WARNING SYSTEM FOR 3-STORIES APT BUILDINGFA PANEL/ANN ON GRND LEV; ONE OF TWO PS POWERS ALL THE MINIHORNS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11544	16041-20000-25352	20948 W KNAPP ST BLDG 1	91311	12	198B109   211	2746009041	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.23844	-118.59063	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  THIS IS BUILDING 1 SUBFEEDING BUILDING 2.  TOTAL QUARE FOOTAGE 9726.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11545	17041-10000-14013	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Installation of new fire alarm system in MDF room of existing mall building.  Total of 16 devices + 1 control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11546	15041-10000-24840	1115 S BOYLE AVE	90023	14	123A221   272	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.0308	-118.22044	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHITGN FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11547	13041-10000-33990	11436 N OSTROM AVE	91344	12	213B133   749	2697017034	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Expired	02/09/2016 12:00:00 AM	ADDRESS	34.27844	-118.50694	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN SINGLE STORY HOME. SYSTEM IS TRANSFORMERLESS & SIZE IS 3.6 kW ON NON-STANDARD PLAN. TOTAL NUMBER OF MODULES IS 15, IN 3 STRINGS VIA DC COMBINER BOX. (15) MODULE: SUNPOWER SPR-327WATT(1) INVERTER: POWER-ONE PVI-3.6-OUTD-US-240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11548	12041-10000-28877	5419 W SUNSET BLVD	90027	13	147A193    65	5544022053	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.09827	-118.30768	T.I.  2 story building with open parking on top.  Current use of the space is retail, converting it to an adult trade school that will occupy the whole building.  New panels, circuits and lighting.  Full plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11549	15041-20001-01798	222 W 6TH ST 2ND FL	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	33.73887	-118.28305	PERMIT ALREADY ISSUED UNDER MASTER APPLICATION. THIS IS PLAN CHECK ONLY FOR T24. ENERGY ONLY. NEW LIGHITNG IN CORRIDORS. EXISTING LIGHTING TO REMAIN IN OFFICE AREAS. NEW CONTROLS. DUE TO BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11550	12041-10001-15645	5755 N ALLOTT AVE	91401	2	174B157   190	2343010012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.17554	-118.42812	Revision to approved plans. Plan check for addition of 2 more modules to PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11551	09041-10001-03128	6215 W SUNSET BLVD	90028	13	147A189    23	5546026019	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM	04/02/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.09817	-118.3244	"Changes from previously approved plans.  Changes are transfered loads from ""EM1"" panel to ""EM1A"" panel, relocated ""EM1A"" panel to electrical room, removed ""EM1"" panel.  All changes indicated by DELTA-14 as shown on plans.   Plan check for power only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11552	15041-20001-30583	23623 W LUND ST	91367	3	171B093   235	2047006021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.16683	-118.64247	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11553	18041-10000-08656	2121 S AVENUE OF THE STARS SUITE 2350	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/14/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES INTERIOR TI  IN A HIGH RISE OFFICE BUILDING. SCOPE OF WORK INCLUDES THE COMBINING OF OFFICE SPACES. TOTAL SQ. FT. 2068	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11554	12041-20000-09849	2029 S CENTURY PARK EAST #200	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to a high rise building portion of the 2nd floor.  Install general/emergency lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11555	15041-10000-10881	8500 S VERMONT AVE BLDG E	90044	8	097-5A199 185	6032013905	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			Corrections Issued	04/18/2015 12:00:00 AM	ADDRESS	33.96105	-118.29134	"NEW DEVELOPMENT 2500 AMP SERVICE, CORE AND SHELL,  PC FOR POWER AND ENERGY. THIS IS BULDING 'E' OF 7 BUILDINGS. TITLE 24 ENERGY CALCS FOR COMMON AREAS TO BE SUBMITTED AT A LATER TIME. ENERGY FEES ARE ESTIMATED BY BUILDING LOAD CALCULATIONS. (((PROPOSED  3-STORY RETAIL AND RESTAURANT BUILDING.THIS BUILDING IS KNOWN AS BLDG ""A""  TYPE VA W/ SPRINKLER SUBSTITUTION FOR FIRE RESISTANCE RATING. )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11556	14041-10002-32210	117 S BOYLE AVE	90033	14	129A221   232	5174013905	C2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Closed	06/07/2017 12:00:00 AM	ADDRESS	34.04687	-118.22011	REVISIONS TO PERMITTED SET OF PLANS: ADDING FIRE PUMP PER LAFD REQUEST; SERVICE TAP FOR THE FIRE PUMP WILL BE AT DWP'S UNDERGROUND SECTION WITH A  SEPARATE METER((((((((((((Full plan check for new appartment(4 stories) with partial first floor commercial(core and shell for commercial first floor).  Service size 2,500 Amps. Note: Variance to seperate fire alarm has been filed (11/19/2014)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11557	17041-30001-40714	1999 S AVENUE OF THE STARS 34th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			PC Approved	05/10/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	Change to approved set by modifing some lighting on the floor plan; Minor square footage also being readjusted. All changes under delta-2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11558	16041-10000-03280	580 W PACIFIC COAST HWY	90744	15	036B205  1172	7420002001	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	33.79066	-118.26925	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (LOAN OFFICE). CHANGE OF USE FROM RESTAURANT TO LOAN OFFICE. SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 1206 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11559	19041-10002-21741	241 E CENTURY BLVD #2	90003	8	091-5A205  81	6052016024	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			Not Ready to Issue	12/30/2019 12:00:00 AM	ADDRESS	33.94575	-118.27027	Changes on approved set. Relocation of modules, plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11560	17041-20001-08158	2269 S GUTHRIE CIR	90034	5	126B165   477	4309017028	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM			PC Approved	03/24/2017 12:00:00 AM	ADDRESS	34.04224	-118.3932	expedite.pv1install roof mounted pv system sized 12.4kw (ACM) interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11561	18041-20000-30162	1559 N PARMER AVE	90026	13	141A211    92	5419014023	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.08086	-118.25391	Plan check for a PV1 roof-mounted PV system. System size is 2.31 kWdc/2.12 kWac-CEC and consists of (6) modules and (6) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11562	15041-10000-04296	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN REVIEW OF RFI FILES FOR CHANGES ON SITE DURING THE BRADLEY  RENOVATIONS-RFI 0162: On 3S1BM1, INCREASED AHU UNIT AND ASSOCIATED FEEDER/DISCONNECT SWITCHRFI 2977: REFEED CRU units from different panel boards (480V,3PH to 208V 3PH )RFI 0146: INSTALL CIRCUITS TO LED MONITORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11563	14041-10000-18710	1801 S FIGUEROA ST	90015	9	124-5A205 282	5126002009	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.03524	-118.27179	((7/11/2014- This is a plan check only application. Revised plans for inspection. Original plan check number is 14041-10000-10950))changes to approved plans: per applicant due to field conditions - oil and air equipment in driveway forced relocation of service equipment routing. service equipment moved. (E) panel G to be used instead of NGA. plan check for power only. .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11564	12041-10001-30868	539 S WESTERN AVE	90020	4	135B193   798	5503018019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.06419	-118.30939	CHANGES TO APPROVED SET. UPDATE TO MATCH FIELD INSTALLATION. fixture schedule: a&b changed to LED. C&G changed to CFL. D&E changed to LED. t.i of prevoius retail space. new restaraunt being contrsucted. occupant load less that 49. plan check for t24 and permit. reloacation of existing panel. charged as new panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11565	17041-20000-40187	9830 N GLADE AVE	91311	12	201B101   197	2727012032	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.249	-118.60812	Note: $0.00 permit fee due to CA Senate Bill 1222PV1.  Install 18 kW roof mounted grid tied PV system.  (60) modules with (2) 6 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11566	19041-10000-49174	230 W OLYMPIC BLVD	90015	14	126A209    76	5139013018	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	08/08/2022 12:00:00 AM		Issued	08/08/2022 12:00:00 AM	PIN	34.0406262	-118.25888287	NEW 59-STORIES MIXED USE BUILDING WITH 602 DWELLING UNITS AND 4 LEVELS OF SUBTERRREANEAN PARKING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11567	16041-10000-42001	8500 W BEVERLY BLVD 501	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR T24 ENERGY ONLY. OFFICE TI TO THE 5TH FLOOR IN A COVERED MALL. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4433 SQ. FT. B#16016-10000-27527	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11568	19041-20000-52822	743 W 123RD ST	90044	15	081B197    26	6117007002	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	33.92124	-118.28847	Plan check for PV roof mounted system, PV system size: 4.65KW with 15 PV modules and 1 inverter(5.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11569	17041-20001-22681	13478 W EGBERT ST	91342	7	228B157    60	2503016011	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	34.32548	-118.42682	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11570	17041-10000-39567	811 W WILSHIRE BLVD 12TH FLOOR	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.04973	-118.2584	TENANT ALTERATIONS IN EXISTING OFFICES- NEW LUMINAIRES AND CIRCUITSPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11571	15041-20000-02786	15125 W HARTSOOK ST	91403	4	171A147    55	2263003016	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Closed	02/14/2017 12:00:00 AM	ADDRESS	34.1641	-118.46278	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.4KW  MICROINVERTER. NON STANDARD PLAN(16) SW 280W MODULES(16) ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11572	12041-20000-19113	14537 W SHERMAN WAY Car Wash	91405	6	183B149    43	2218024008	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.20136	-118.44984	Plan check for new car wash. 4378 total combined sqft (title 24). NON-METHANE.  Appears to be multiple buildings on the site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11573	16041-10000-12551	3647 S HUGHES AVE	90034	5	120B165   521	4313008010	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			04/11/2016 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	05/25/2022 12:00:00 AM	ADDRESS	34.02638	-118.40146	NEW 5 STORY APARTMENT (8-UNIT) OVER ONE LEVEL OF SUB-TER GARAGE. 800 A SERVICE. TOTAL  AREA: 5647 SQ. FT (INDOOR) + 3,029 SQ.FT (OUTDOOR).Build# 16010-10000-00894	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11574	17041-20000-03401	1999 S AVENUE OF THE STARS 37 flr	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	ti to an existing commercial building (high rise) adding new lighting new controls to existig panels.  plan checkfor energy and emegency lighting.  toal square footage 1614.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11575	19041-20000-01097	6509 W DE LONGPRE AVE	90028	13	147A187   250	5546014016	C2-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	09/28/2020 12:00:00 AM		Permit Finaled	05/30/2022 12:00:00 AM	ADDRESS	34.09625	-118.33056	Plan check for Title 24 only in existing space Tenant Improvement ground level. Total area: 3458 sq ft. B#18016-30000-28038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11576	16041-20000-42799	5958 N CALVIN AVE	91356	3	177B117   678	2153034015	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.17897	-118.55548	"""0$ permit fees due to senate bill 1222""Plan check for installation of solar pv system roof-mounted on SFD. Interconnect with a 200A MSP. Derating the main to 150A. 14.31kW ungrounded system.  (53) EnPhase S280 microinverters (53) 320W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11577	19041-10000-35104	8055 N RESEDA BLVD	91335	12	189B125   165	2103009039	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.21698	-118.53627	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11578	12041-10000-16434	11726 W PICO BLVD	90064	11	123B149   752	4260030016	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.03117	-118.44618	REMODELING EXISTING HEALTH -2 EA NEW CIRCUITS FOR LIGHTING AND RECEPTACLE LOADSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11579	10041-20000-01025	19307 W SATICOY ST	91335	3	186B117  1034	2116014019	QC2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM	01/20/2010 12:00:00 AM		Permit Finaled	03/17/2010 12:00:00 AM	ADDRESS	34.20851	-118.55435	us bank energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11580	15041-20000-18116	3079 W SAN FERNANDO ROAD	90065	13	153A213    60	5458009018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			Corrections Issued	06/11/2015 12:00:00 AM	ADDRESS	34.11475	-118.24554	Title 24. TI to existing commercial building (retail). Plan check for energy only. Adding new lighting including emergency. Total sqft. 2,437.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11581	10041-20001-12720	12039 W BRANFORD ST	91331	7	204B165   189	2537017017	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM			PC Approved	07/13/2010 12:00:00 AM	PIN	34.25485468	-118.39602222	Revision on approved plans for 500MCM to juction box and 3/0 MCM feeder to Panel 1J	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11582	18041-20000-29942	615 W FLORENCE AVE	90044	8	102B201   857	6013024013	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	33.97482	-118.28428	New pole mounted lighting for (E) service station.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11583	15041-20000-19292	7606 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.20879	-118.46478	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11584	19041-10000-53257	8900 W VENICE BLVD	90232	5	120B169    20	4312014093	(Q)M1-2D	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	04/30/2020 12:00:00 AM		Permit Finaled	09/01/2020 12:00:00 AM	ADDRESS	34.02908	-118.38822	PV2. NEW SOLR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 71.04KWdc / 62.5KWac. (222)MODULES- BOVIET BVM6612P-320W/5BB(320W)(1)INVERTER-SMA TRIPOWER CORE1 STP 62-US-41 - $0 permit fees due to AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11585	14041-10000-02272	920 W 28TH ST	90007	9	121-5A201  52	5123004403	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.02846	-118.28299	TENANT IMPROVEMENT AT THE DELTA CHI FRATERNITY HOUSE- ADD AN INVERTER AS EMERGENCY POWER SUPPLY AND NEW PANEL TO SUPPLY NEW CIRCUITSPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11586	14041-10000-29131	10270 W ALMAYO AVE	90064	5	129B161   275	4315014089	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.04948	-118.41336	Plan check for a fire alarm system for a 4 story apartment building. (75) new devices and a new panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11587	17041-10000-36791	5725 N JUMILLA AVE	91367	3	174B117   144	2153018003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.17512	-118.5641	PC FOR BATTERY BACKUP TESLA POWERWALL 2.INCLUDING NEW SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11588	16041-20000-21757	7920 N CHASTAIN AVE	91335	7	213B173   399	2529020007	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Expired	08/02/2018 12:00:00 AM	ADDRESS	34.21425	-118.52365	PV1ADDITION TO AN EXISTING SYSTEM.  ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11589	12041-20000-24647	3409 S OVERLAND AVE	90034	5	120B161   590	4254025039	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.02566	-118.41255	Plan check for energy and emergency lighting. 1889sqft. Coffee shop. Single story stand alone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11590	09041-10001-03965	1030 N ALVARADO ST	90026	13	139-5A207 130	5404003031	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM			PC Approved	07/02/2010 12:00:00 AM	ADDRESS	34.07715	-118.26352	REVISION OF PERMITTED SET OF PLANS: FOR SWBD MSB, SEPARATE FEEDERS TO SUPPLY THE ELEVATOR AND PANELS HP1 AND HP2 AND CHANGE FEEDERS TO THE PNLS FROM CU TO AL ; FOR SWBD MSA, CHANGE FEEDERS FROM CU TO AL,RECALCULATE VOLTAGE DROPS; FOR THE INDIVIDUAL APT UNITS, STOVE/OVEN IS ONE APPLIANCE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11591	19041-10000-42530	18148 W ELKWOOD ST	91335	12	189B125   660	2102017100	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	34.21282	-118.52904	NEW ROOF-MOUNTED PV1 INSTALLATION FOR AN EXISTING SERVICE OF 125 AMPS. INSTALLATION INCLUDES 1 CENTRAL INVERTER (SE5000H-US), 19 MODULES (CANADIAN SOLAR), AND 2 OPTIMIZERS (P320) SYSTEM SIZE: 5.39 KW DC/5 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11592	13041-10000-32166	12895 W RUNWAY ROAD UNITS 1-6-BLDG 2	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/26/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	33.9751	-118.42068	INSTALLATION OF A NEW FIRE ALARM SYSTEM for a 4 story residential building (Building 2). THIS IS BUILDING 2 OF 6. THE FACP WILL BE ON BUILDING 2. Building shares service with 5 other buildings on site. There are two building types for the site. Building 2 plan is  type 6 ( SIGNIFYING 6 PLEX ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11593	19041-20000-39295	12400 W WILSHIRE BLVD 910	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Issued	09/30/2019 12:00:00 AM	ADDRESS	34.04157	-118.47031	T24 PLAN CHECK FOR TI TO EXISTING COMMERCIAL BUILDING STE 910. LIGHTS AND OUTLETS ONLY TOTAL SQUARE FOOTAGE = 1376 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11594	11041-10000-25445	3525 W 8TH ST	90005	10	132B193   572	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			PC Approved	11/29/2011 12:00:00 AM	ADDRESS	34.05782	-118.30714	title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11595	12041-10000-23225	10261 N GLENOAKS BLVD	91331	7	204B165   134	2537017065	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			Reviewed by Supervisor	10/23/2012 12:00:00 AM	ADDRESS	34.25646	-118.39487	Roof mounted P.V. system ( 113.5 KWdc) for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11596	15041-10000-06793	12017 1/2 W VOSE ST	91605	2	183B165   111	2321003034	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.39489	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11597	16041-10001-36988	11320 N MCLENNAN AVE	91344	12	210B133    30	2682026020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM			PC Approved	11/17/2016 12:00:00 AM	ADDRESS	34.27622	-118.50091	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.65KWdc / 11.2KWac.(46)MODULES-REC SOLAR REC275TP(1)INVERTER-NINGBO GINLONG TECHNOLOGIES: SOLIS-3.6-2G-US(1)INVERTER-NINGBO GINLONG TECHNOLOGIES: SOLIS-3.6-2G-US(1)INVERTER-NINGBO GINLONG TECHNOLOGIES: SOLIS-4K-2G-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11598	12041-10000-19248	851 W DOWNEY WAY	90089	8	118-5A201  14	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.02004	-118.28659	PLAN CHECK NEW FIRE ALARM SYSTEM FOR USC HAZEL STANLEY HALL BUILDING (1ST TO 3RD FLR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11599	16041-10001-16550	17383 W SUNSET BLVD	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM			PC Info Complete	02/03/2017 12:00:00 AM	ADDRESS	34.03917	-118.55529	02/03/2017 Changes to an approved set of plan. Changes include add inverters to feed the emergency lighting in P1 level common area. Changes has been clouded as delta.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11600	14041-20001-15122	7130 N GATESHEAD WAY	91307	12	183B093   178	2028023011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.19952	-118.63986	Fee for expedite only.*****New roof mounted PV system with optimizer and transformerless inveter.  Total system size11.1KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11601	19041-10000-41094	15045 W SATICOY ST	91405	6	186B145    87	2209035025	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	34.20859	-118.4608	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11602	12041-20000-20881	13640 W FOOTHILL BLVD	91342	7	222B157    94	2509014014	(T)(Q)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			09/04/2012 12:00:00 AM			PC Info Complete	10/05/2012 12:00:00 AM	ADDRESS	34.3076	-118.43089	Full plan check for revisions to previously approved set of plans.  Original approved set of plans submitted for comparison.  Plans are updated to show exact addtion to an approved plan.  Only three new panles are added , the rest are existing.  Lights been removed therefore T24 was checked for the whole area. plan check is for the new panels and total T24.  Charge additional plan check fees for T24 which was omitted.  Electrical permit  was issued under 11041-20000-20748.  This job is plan check only.  All fees been paid	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11603	14041-20000-00112	12903 W SHERMAN WAY A-C	91605	2	183B161    36	2327016031	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.20135	-118.41433	T24 FOR EXISTING SPACE. DIVIDING INTO 3 SPACES. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. SCOPE OF WORK IS ON UNITS A, B, C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11604	10041-10000-18465	10100 W SANTA MONICA BLVD 16th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	12/20/2010 12:00:00 AM	ADDRESS	34.06191	-118.41691	Remodel portion of a major portion of the 16th floor.  Plan check is for lighting with emergency lighting varification.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11605	13041-20000-17264	21031 W VENTURA BLVD #701	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Issued	07/09/2013 12:00:00 AM	PIN	34.16717222	-118.59179488	Change to lighting in an existing low-rise office building.  Load is less than 400 amps.  Plan check only for Energy.   No emergency lighting per applicant.  Permit fees are under INSPECTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11606	16041-20002-18893	4612 N VAN NOORD AVE	91604	2	168B161   866	2362005008	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	PIN	34.15439689	-118.41461249	$0 PLAN CHECK FEE DUE TO STATE SENATE BILL SB 1222((CHANGES TO APPROVED SET.  RELOCATION OF EQUIPMENT FROM MAIN HOUSE TO GARAGE))PV1.  Install 15.3 kW roof-mounted PV system.  (48) 320W PV modules with (1) 11.4 kW central inverter with power optimizers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11607	19041-10000-33128	1550 W 35TH PL	90018	8	120B193  1082	5041011902	OS-1XL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.02356	-118.30447	NEW FIRE ALARM SYSTEM WITH 65 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11608	16041-10000-43972	13075 W VICTORY BLVD 101	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			PC Info Complete	01/05/2017 12:00:00 AM	ADDRESS	34.18684	-118.41708	T-24, PC for energy only. TI to a restaurant space. Scope includes new lights and receptacles. Total affected area is 2077 Sq. Ft. B#16016-30000-29995	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11609	16041-10000-09333	6224 W MANCHESTER AVE	90045	11	096B165   564	4123003020	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	33.9596	-118.3945	T-24, PC FOR ENERGY ONLY. TI FOR LEASE SPACE #1. CHANGE OF USE FROM MEDICAL OFFICES TO RESTAURANT. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1602 SQ. FT.NOTE: PERMIT PAID UNDER PCIS#16041-70000-08392 / X16SL00964	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11610	13041-20000-19682	17522 W SHERMAN WAY	91406	6	183B129   172	2228020***	(Q)RD1.5-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Issued	07/24/2013 12:00:00 AM	ADDRESS	34.20092	-118.5148	REPLACING EXISTING FIRE ALARM PANEL WITH NEW. ADDITIONAL 16 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11611	11041-20000-26199	20235 W NORDHOFF ST	91311	12	195B113    64	2781035041	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.23201	-118.57449	New electrical system for interior space remodel.  Plan check for electrical, and energy.Submittal 2 is for the payment of the expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11612	15041-20000-16438	12840 W RIVERSIDE DR SUITE 300	91604	4	168B161   459	2357033012	C1.5-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	PIN	34.15731555	-118.4128018	PLANCHECK FOR POWER ONLY.  PLANCHECK ONLY .TENANT IMPROVMENT TO (E) MEDCAL CLINIC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11613	18041-10000-47827	9029 S AIRPORT BLVD	90045	11	093B169     5	4123018928	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	33.95313	-118.38624	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11614	12041-10001-08437	800 S FIGUEROA ST 7th Floor	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM			PC Info Complete	04/13/2012 12:00:00 AM	ADDRESS	34.04771	-118.26116	TI IN AN EXISTING LOBBY, RESTROOMS AND CORRIDOR AREA OF THE 7TH FLOOR.  REPLACING EXISTING LIGHTS. PERMIT WAS ISSUED UNDER 12041-70000-08437.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11615	16041-30001-18220	24417 W CLIPSTONE ST	91367	3	177B085   414	2032013043	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2016 12:00:00 AM			PC Approved	06/02/2016 12:00:00 AM	ADDRESS	34.17944	-118.65729	06/02/2016 Changes to an approved set of plans. All changes have been reflected onto Standard Plan.*****Previous Work Description*****PV1.  Install 8.2 kW roof mounted PV system.  Comprehensive central inverter standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11616	13041-20000-21427	18907 W DEARBORN ST	91324	12	198B121   623	2762025032	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.23745	-118.54522	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW USING 23 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11617	10041-10000-24567	1080 W WILSHIRE BLVD	90017	1	130-5A207 135	5143027016	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.05202	-118.2632	NEW DENTAL OFFICE. FIRST TIME TENANTS. PLAN CHECK IS FOR POWER AND ENERGY.  CORE & SHELL APPROVED UNDER A DIFFERENT APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11618	19041-20000-28020	1200 S FIGUEROA ST ste 100	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.04166	-118.26677	first time tenant.  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11619	18041-10000-46417	1115 S LA CIENEGA BLVD	90035	5	132B173   763	4332029016	C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.05653	-118.37637	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11620	15041-10000-12501	7920 W SUNSET BLVD 5th Flr	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.09787	-118.36238	Energy plan check for an office T.I located at the 5th floor of a high rise building. total area is 6010-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11621	19041-20000-41052	11881 W TERRA VISTA WAY #106	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/12/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11622	13041-20000-30500	7500 N CHAMINADE AVE	91304	12	186B093    52	2027005009	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.20673	-118.63673	New outdoor sign for an exising private high school.  Building permit has been approved.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11623	15041-10000-36182	764 N TERRACE 49	90042	1	153A223   397	5471015024	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	04/09/2016 12:00:00 AM	ADDRESS	34.11165	-118.20945	PV1, INSTALL 3.0 KW DCROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: HYUNDAI SOLAR (1) INVERTER: ABB PVI-3.0-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11624	13041-10001-35514	413 W 104TH ST	90003	8	090A201    41	6061029015	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.94201	-118.28095	Expedited RSES plan check per applicant request.{{PV1, Install 4.25 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (17) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11625	15041-10000-04651	2300 N ALTO OAK DR	90068	4	153B193   438	5587008039	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM			Reviewed by Supervisor	03/05/2015 12:00:00 AM	ADDRESS	34.11179	-118.31337	Power plan check for new single family dwelling.  Fees are based on applicant provided numbers (for reference only) -> verify fee count at time of submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11626	14041-20001-34877	9912 N MARNICE AVE	91042	7	201B205   400	2571016063	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.24743	-118.27179	EXPEDITED PER CUSTOMER REQUEST.PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(26) SOLAR WORLD 275W MODULES(26) SOLAR EDGE P300 POWER OPTIMIZERS(1) SOLAR EDGE SE7600A-US INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11627	10041-20000-07850	17420 W VENTURA BLVD	91316	5	171B129   462	2290004001	C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Closed	07/08/2010 12:00:00 AM	ADDRESS	34.16108	-118.51247	TI in restaurant doing lighting and power in restaurant. This P/C is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11628	18041-20001-45468	12208 N DELANTE WAY	91344	12	219B125   107	2601074014	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.29569	-118.52793	Epedite per applicant requestPlan check for PV roof mounted system, system size: 19.140kW DC, 17.875kW AC wtih 58 PV Modules and 2 inverters(7.6kW and 10.0KW) connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11629	19041-10000-43567	2201 E TROJAN WAY	90033	14	135A225   143	5202001011	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Apartment			10/24/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.06467	-118.2022	NEW FIRE ALARM SYSTEM WITH 1,118 DEVICES AND 8 FIRE ALARM PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11630	10041-10002-09310	1600 N VINE ST Unit 3	90028	13	148-5A189 346	4307013027	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM			Corrections Issued	09/30/2010 12:00:00 AM	ADDRESS	34.1	-118.32647	Modifications to the interior lighting plan, check for T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11631	18041-10001-41926	1770 N HIGHLAND AVE SIGN	90028	13	150A185   358	5547002036	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.10363	-118.33849	PC ONLY FOR EXTERNAL SIGN. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECETED AREA IS 672 SQ,FT. T-24 ONLYPERMIT FEES ARE PAID UNDER MASTER APLICATION. 18041-10000-41926	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11632	17041-20000-42583	20048 W LEMARSH ST	91311	12	204B113   372	2726024023	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Re-Activate Permit	03/30/2018 12:00:00 AM	ADDRESS	34.25503	-118.57058	pv1install roof mounted pv system sized 7.6kw interconnected with msp.  center fed panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11633	13041-10000-23200	2650 E OLYMPIC BLVD	90023	14	120A221    99	5169010006	C2-1, M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Issued	09/24/2013 12:00:00 AM	ADDRESS	34.02485	-118.22188	pc for energy only. TENANT IMPROVEMENT FOR MEN'S RESTROOM AT 2ND FLOOR OF (E) RETAIL  STORE  : NEW PLUMBING FIXTURES ; NEW CEILING PANELS ; NEW WALL & FLOOR FINISHES .no work is done on the outside, CRA is okay	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11634	16041-20001-45450	341 S KENMORE AVE 1-63	90020	10	135B197   399	5502004015	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Approved	05/05/2017 12:00:00 AM	ADDRESS	34.06776	-118.29683	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11635	19041-10000-42830	3551 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.02066	-118.28531	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, NEW LIGHTING, CONTROLS AND CIRCUITS, TOTAL AFFECTED AREA IS 2590 SFQT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11636	17041-10000-03646	17100 W ROSCOE BLVD	91325	6	192B133   274	2204002002	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.22097	-118.50581	PC for a PV roof mounted solar installation on a single family home. Installing 14 modules with integraded micro inverter. Total size of system is 4.578 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11637	13041-10001-33033	1160 N RAVOLI DR	90272	11	129B133   144	4425010019	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.05107	-118.50789	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 7.5 KW. STANDARD PLAN(30) TRINA SOLAR # TSM-250(1) FRONIUS IG PLUS 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11638	13041-20000-35468	2031 W PANAMINT DR	90065	1	151-5A219 167	5462017023	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.10956	-118.22529	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 27 MODULES TRANSFORMERLESS INVERTER NONSTANDARD PLAN.  3 STRINGS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11639	19041-10000-53720	1640 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   337	5021007037	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	07/28/2022 12:00:00 AM		Permit Finaled	12/12/2023 12:00:00 AM	ADDRESS	34.01069	-118.30735	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW 800A 277/480V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW 45KVA TRANSFORMER, NEW 400A DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 20,888 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11640	15041-20000-32739	8510 N INDEPENDENCE AVE	91304	3	192B109   193	2779010183	R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.22482	-118.5906	PV1. Install roof mounted PV system sized 6.0 kW. Interconnected with main service panel. (27) Kyocera KU 265 Modules(1) ABB PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11641	18041-10000-26329	3150-3158 W OLYMPIC BLVD	90006	10	129B193   327	5080022016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.05238	-118.30484	CONVERT ONE RETAIL SPACE INTO 4 RETAIL SPACES.  NEW 600 AMP SERVICE, PANEL & LOADS.PLAN CHECK FOR POWER & ENERGY.BUILDING PERMIT: 17016-10000-13685	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11642	12041-10000-25070	1441 N CHAUTAUQUA BLVD	90272	11	132B129    16	4422003002	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.0562	-118.52248	"(N) 52' X 69'-6"" 3 STORY SFD W/ATT. GARAGEPERMIT ON SEPARATE APPLICATION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11643	14041-20000-31907	8619 N RESEDA BLVD	91324	12	195B125  1017	2785005025	C2-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Expired	12/12/2016 12:00:00 AM	ADDRESS	34.22697	-118.53634	PC FOR FIRE ALARM SYSTEM. 17 DEVICES AND CENTRAL CONTROL PANEL. OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11644	10041-30000-10565	10800 W PICO BLVD 382	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	06/18/2010 12:00:00 AM		Permit Finaled	09/02/2010 12:00:00 AM	ADDRESS	34.04054	-118.4272	LIGHTING AND POWER IN RETAIL STORE. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11645	18041-10000-09742	313 N FIGUEROA ST	90012	14	133-5A211 143	5161002908	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			Reviewed by Supervisor	04/30/2018 12:00:00 AM	ADDRESS	34.05972	-118.24939	PC for power for new 450kW generator for Health Department builing. Installing generator, transfer switch,  load bank for generator support, and replacing existing 600A EDB-1 board with new 800A distribution board. NOTE: Temporary 600A panel is shown on E1.4(Note 10) to temporary supply loads on EDB-1 while 800A distribution board is put in place shall be under future seperate permit.B: 1820-10000-00700.**REMOVE DIESEL GENERATOR AND ASSOCIATED EQUIPMENT FROM BASEMENT AND REPLACE WITH NEW 450 KW GENERATOR WITH FUEL TANK AND ASSOCIATED EQUIPMENT (AUTOMATIC TRANSFER SWITCH, LOAD BANK AND TANK) TO OUTDOOR WITH  8' HIGH SECURED INDUSTRIAL ALUMINUM FENCE AND A MANGATE AROUND THE GENERATOR AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11646	13041-10000-14986	5817 S CRENSHAW BLVD	90043	8	108B185  1014	4005004020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	33.98847	-118.33114	PC FOR ENERGY ONLY. LESS THAN 400A PER APPLICANT. fat burger buffalo cafeTENANT IMPROVEMENT TO EXISTING RESTAURANT, REMOVE AND NEW NON-BEARIG PARTITION, NEW MILLWORK AND FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11647	19041-10000-13221	1827 N JOHNSTON ST	90031	1	135A223    67	5210016008	M1-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	08/05/2020 12:00:00 AM		Permit Finaled	06/30/2022 12:00:00 AM	ADDRESS	34.06519	-118.21031	FULL PLAN CHECK FOR A NEW ONE STORY BUILDING FOR CHRONIC DIALYSIS CENTER, (OUTPATIENT CLINIC).  SCOPE INCLUDES NEW 600A SERVICE. TOTAL AFFECTED AREA IS 16955 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11648	18041-10000-00728	10710 N FULLBRIGHT AVE	91311	12	207B113    80	2707004018	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.265	-118.57683	PC for rooftop solar for 7.84kW system. Installing 28 modules with IQ6plus.72.2.US microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11649	18041-20000-43649	2185 N OUTPOST DR	90068	4	153B181   364	5572014011	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	10/14/2020 12:00:00 AM	ADDRESS	34.11165	-118.34633	PV1.  Install 12.96 kW roof mounted grid tied PV system.  (36) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11650	14041-10000-04978	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022057	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM			Reviewed by Supervisor	03/10/2014 12:00:00 AM	ADDRESS	34.21384	-118.44905	NEW 6 STORY  FITNESS CENTER WITH INDOOR SWIMMING POOL & SPA & SONA  & PARKING (2 LEVELS OF FITNESS CENTER &  4  LEVELS PARKING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11651	16041-10000-21748	6926 N LANKERSHIM BLVD	91605	2	183B169   304	2320008029	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.19695	-118.38758	Remove HID fixture and replace with new LED fixture. PC for T-24 only.  Total area: 8,950 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11652	13041-20000-10588	10021 N MELVIN AVE	91324	12	204B117   532	2726011012	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.25248	-118.56094	New enphase microinverter PV System on the roof of an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11653	19041-10000-35080	5500 W SUNSET BLVD	90028	13	147A193   108	5544029011	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.09793	-118.30958	"NEW FIRE ALARM SYSTEM WITH 474 DEVICES IN A NEW ""TARGET"" STORE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11654	17041-20000-09618	7724 N VICKY AVE	91304	12	189B097  1090	2013018023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.21079	-118.61933	Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with 225A MSP.12.8kW ungrounded system. (40) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11655	15041-10000-24489	600 WORLD WAY 660-662 665	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	LAX Terminal 6 restaurant TI for Wolfgang Puck.  First time tenant.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11656	13041-10000-35894	6515 W SUNSET BLVD	90028	13	147A187   104	5547017037	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.09815	-118.33161	PLANCHECK FOR T24 ENERGY ONLY. NEW CONNECTED LOAD < 400 AMPS. 8175 SQFT, EMERGENCY LIGHTING.TI for second and forth floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11657	14041-20000-16214	8521 N FALLBROOK AVE	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.22368	-118.62797	plan check for title 24 energy and emergency lighting for an existing commercial building 23120 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11658	17041-20000-39316	7635 N TOBIAS AVE	91405	6	186B149    87	2210029014	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.20974	-118.45214	Plan check for power only. Service upgrade to 600A 120/240V 3ph 4w for existing commercial building. Replace existing sub-panels for series rating compatibility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11659	17041-10000-20429	1600 N CAMPUS ROAD HINCHLIFFE-HALL	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM			PC Info Complete	06/21/2017 12:00:00 AM	ADDRESS	34.12626	-118.21412	T-24, PC FOR ENERGY ONLY. TI FOR A CONFERENCE ROOM WITHIN AN EXISTING SCHOOL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS  1417 SQ. FT.  B#17016-10000-16354	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11660	17041-10002-30454	601 S ARDMORE AVE 100	90005	10	135B193   875	5503025014	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.06322	-118.30183	Changes to an approved set of plans. All changes are clouded under delta 2. changes include revising conductor sizes on single line diagram, and revising fault current values. Note: Permit is issued under PCIS#17041-10000-30454	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11661	16041-10000-12682	10743 W CUMPSTON ST	91601	2	174B177   896	2416017029	R1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			04/12/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.1701	-118.36511	PV2. INSTALL 4.578 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER SPR-327-NE-WHT(1) INVERTER: POWER-ONE PVI-4.2-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11662	10041-20000-12094	463 S LA BREA AVE	90036	4	135B181   576	5508006014	C2-1	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Closed	11/16/2012 12:00:00 AM	ADDRESS	34.0651	-118.34421	Plan check T-24 Energy outdoor lighting. All circuits are existing. Permit for (7) light fixtures and (2) receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11663	19041-20000-51769	4337 N WOODMAN AVE	91423	4	165B157   483	2271018013	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.14918	-118.43139	Plan check for Title 24 energy only, new indoor lighting in the space. Total area:1900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11664	13041-20000-04800	521 S GRAND VIEW ST	90057	1	133-5A203 107	5154037032	C2-2	Central	Westlake			2088.01	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Info Complete	04/23/2013 12:00:00 AM	ADDRESS	34.06095	-118.27678	New panel, lighting and loads in an existing Medical Clinic.  Not State Licensed, OSHPD3 Exempt, per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11665	14041-20000-31786	3945 N EAGLE ROCK BLVD BLD. G	90065	13	154-5A217 334	5460001043	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Apartment			11/17/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.12007	-118.22985	New 8-unit condomnium/garage (3 story).  Install new 600A service, panels, and branch circuits.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11666	14041-20001-34456	7820 N AMPERE AVE	91605	2	189B161   809	2303014049	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	34.21255	-118.41781	EXPEDITED PER APPLICANTS REQUESTPV1 SFD. TOTAL SYSTEM SIZE 8.62 KW AC USING TRANFORMERLESS INVERTER. USING TOTAL OF 34 MODULES. 2 INVERTERS. 4 STRINGS     CONNECTED WITH EXISTINGS 3.8 KW SYSTEM. TOTAL SYSTEM SIZE INCLUDING EXISTING: 11KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11667	17041-20000-41123	19823 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	33.85048	-118.28713	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 36 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11668	11041-20000-04169	818 W 7TH ST #400	90017	9	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	03/17/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.04895	-118.25943	PLAN CHECK T24 ENERGY/EMERGENCY TENANT IMPROVEMENT SUITE #400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11669	14041-10004-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	03/16/2016 12:00:00 AM	ADDRESS	34.0504	-118.26023	"DELTA 4 CHANGES MADE IN THE FIELD; ATTACHED IS  A LIST OF THE CHANGES THAT ARE CLOUDED AND MARKED ""DELTA 4"".CHANGES INCLUDEINCRESING FEEDER SIZES ; INCREASE MV FUSE SIZE TO ENABLE TRASFORMERS IN-RUSH CURRENTS; NEW PANES; CHANGE CIRCUITS DEIGNATIONS FOR FEW LOADS.PLANCHECK FOR POWER AND ENERGY. HIGH RISE CORE AND SHELL BUILDING INCLUDING 5 LEVEL PARKING GARAGE. "" WILSHIRE GRAND "" PROJECT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11670	16041-10000-21457	1041 N ALVARADO ST BLDG D	90026	13	139-5A207 146	5402035022	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM			PC Approved	06/17/2016 12:00:00 AM	ADDRESS	34.07692	-118.26407	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW INTERIOR AND EXTERIOR LIGHTS FOR A STORAGE SPACE. TOTAL AFFECTED AREA IS 490 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11671	13041-10000-21951	21650 W OXNARD ST 6TH FLOOR	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	TITLE 24 PLAN CHECK ONLY. HIGH RISE. 377 SQFT, EMERGENCY LIGTING. WORK ON THE 6TH FLOOR. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11672	17041-10000-22785	18441 W VENTURA BLVD	91356	3	171B125    19	2160008031	C2-1, C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Approved	07/07/2017 12:00:00 AM	ADDRESS	34.16839	-118.5346	"PC PER INSPECTION FOR POWER IN MEDICAL FACILITY "" AUDIO EXAMINATION ROOM"" IN CVS PHARMACY. PLAN CHECK ONLY!PERMIT PULLED UNDER 17041- 20000-17597INSTALL 50 AMP PANEL AND 8 NEW CIRCUITS FOR AUDIOMETRIC SOUND ROOM, MODIFY (E) PHOTO LAB.  NOT FOR LIGHTING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11673	19041-10000-42718	6101 W 96TH ST ITF-WEST	90045	11	093B169   346	4124020***	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	06/17/2021 12:00:00 AM	ADDRESS	33.94901	-118.39043	TEMPORARY POWER FOR THE CONSTRUCTION OF THE LAX ITF WEST FACILITYPERMIT IS FOR SERVICES;UL LISTED TEMP POWER 75KVA AND 45KVA SKIDS, AND MANLIFTS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11674	15041-20000-13990	6121 W SUNSET BLVD	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	FULL TI TO ALL 6 FLOORS. CORE AND SHELL UNDER SEPARATE PERMIT. THIS TI IS FOR THE NEUEHOUSE.THIS IS A NEW SUBMITTAL WITH NEW PERMIT. ALL PREVIOUS APPLICATIONS VOID. THIS PLAN CHECK AND PERMIT TO COMPLY WITH 2008 VERSION OF THE CALIFORNIA ENERGY CODE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11675	18041-10000-23755	515 S FLOWER ST 41ST Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI IN THE RESTROOMS, ELEVATOR LOBBY AND COMMON AREAS OF THE 41ST FLOOR.BUILDING PERMIT: 18016-10000-14453	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11676	13041-10000-07892	12117 W VANOWEN ST	91605	2	183B165   643	2321026033	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.19408	-118.39726	PHOTOVOLTAIC SYSTEM FOR COMMERCIAL BUILDING, HARDWARE STORE. PV2 SYSTEM USING ENPHASE MICROINVERTER. M215. TOTAL OF 20 PANELS. SYSTEM SIZE 4.3 KW.  NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11677	16041-10001-36266	10250 W SANTA MONICA BLVD # 1840	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	11/10/16: Changes to approved set under Delta-A, consists of Updating note on power and communication data outlets, revise emergency lightings and its photometric.  This is plan check only, permit shall be issued under master plan 16041-10000-36266.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11678	13041-20000-19307	23808 W CALVERT ST	91367	3	177B089   411	2045010010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.18152	-118.64478	New 5.46kw Roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED and uses Enphase Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11679	19041-20000-11640	12345 W VENTURA BLVD Suite L	91604	2	162B165   182	2367018003	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.14309	-118.40246	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,325 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11680	11041-10000-17412	5769 W BRIARCLIFF ROAD	90068	4	151-5A191 215	5587012012	RE9-1	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.10852	-118.3159	UPGRADE SERVICE TO 1000A; add 400A distribution board for future paneboards	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11681	18041-20000-21374	20140 S WESTERN AVE	90501	15	057B193    32	7351021038	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	33.84868	-118.30902	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11682	17041-20000-17017	7920 W SUNSET BLVD Ste 403	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.09787	-118.36238	TI to (E) commercial office space.  Plan check for energy.  Associated building permit under 17016-10000-12415	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11683	14041-10000-04006	12430 1/2 N GLADSTONE AVE	91342	7	219B161   221	2525019065	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.29593	-118.41177	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.Not hazardous per applicant. Inspector to verify.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11684	10041-20000-10943	3121 S LA CIENEGA BLVD	90016	10	123B173  1581	4205035009	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	06/14/2010 12:00:00 AM		Permit Finaled	09/10/2010 12:00:00 AM	ADDRESS	34.02996	-118.37306	Lighing and power in office area. This P/C is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11685	17041-10000-00037	20953 W OSBORNE ST	91304	3	195B109    47	2779001030	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.23315	-118.59033	PC for a new Fire alarm system for an existing commercial building. Scope includes adding (2) New FA panels, and (20) FA Devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11686	15041-10001-05423	9763 W SUFFOLK DR	90210	5	159B157   245	4385001026	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.12924	-118.42896	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(67) KYOCERA KD255GX MODULES(3) ABB INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11687	16041-20000-44220	3018 W PICO BLVD	90006	10	129B193  1317	5074002009	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.04703	-118.30668	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is to remove outdoor HID fixtures and replace with new LED fixtures. Total lighting area = 3,730 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11688	11041-10000-23260	8702 W PICO BLVD	90035	5	132B169  1041	4303010005	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM			PC Approved	10/31/2011 12:00:00 AM	ADDRESS	34.05421	-118.38178	"CHANGE OF USE  FROM A MEDICAL OFFICE ( 19' 4"" X 83' 2"" ) PORTION OF FIRST FLOOR TO BAKERY RETAIL& RESTAURANT (TAKE-OUT ONLY) , MAX .  3 EMPLOYEES PER SHIFT. (NO SEATING) PLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11689	15041-10000-33447	1225 W 38TH ST	90037	8	117B197   450	5037013031	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.01743	-118.29828	PV1, INSTALL NEW 3.975 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(15) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11690	16041-20000-44231	420 W BERNARD ST	90012	1	136-5A215 180	5414007***	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.0669	-118.23673	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is to remove outdoor HID fixtures and replace with new LED fixtures. Total lighting area = 4,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11691	14041-20000-20865	1320 S MATEO ST	90021	14	121-5A217 115	5166009013	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.02826	-118.23205	"Upgrade of electrical service equipment to accommodate additional tenant load.  Upgrade from 200A to 600A service.  All tenant subpanels and brach circuits are under separate application.  All existing lightings to be remained.  Plan check for power only.""COMPLY WITH DEPARTMENT ORDER effective date09/27/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11692	18041-10000-43911	771 E PICO BLVD	90021	14	123A211   108	5132012056	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.0319	-118.25168	PLAN CHECK FOR TITLE 24 ONLY TO REPLAE THE  EXSITING INSTALATION  FOR RETAIL SCOPE OF WORK INCLUDES 8515 SQFT AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11693	15041-10001-42649	2022 S PACIFIC AVE	90291	11	106-5A145 377	4238022001	[Q]C1-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM			PC Approved	12/31/2015 12:00:00 AM	ADDRESS	33.98521	-118.47003	12/31/15CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1. CHANGES INCLUDE A DIFFERENT SINGLE LINE DIAGRAM  LAYOUT ON THE PLANS. PC ONLY(((PC FOR ENERGY.  T.I. FOR FOOD AND VINE ONE STORY BUILDING. NO CHANGE OF USE. TOTAL AREA 1226 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11694	18041-10000-43085	14522 1/2 W VENTURA BLVD	91403	4	166-5A151 137	2276001005	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Issued	01/25/2019 12:00:00 AM	PIN	34.15075871	-118.44960626	t-24 only for an existing resturan. area is 650sq-ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11695	15041-10000-08215	850 N MISSION ROAD	90033	14	132A221   112	5410009913	M1-2D-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM			PC Info Complete	04/08/2016 12:00:00 AM	ADDRESS	34.05786	-118.21756	Full plan check for a new 600-Amp service, commercial building and a 30,000-SQ feet parking lot. Scope mainly includes (1) service, (3) panel and a 30-hp compressor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11696	15041-20000-42306	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	PC FOR POWER AND ENERGY. TI TO AN EXISTING COMMERCIAL BUILDING (365 GROCERY STORE). SCOPE INCLUDES NEW PANELS, BRANCH CIRCUITS, TRANSFORMERS, AND LIGHTING. TOTAL AREA IS 31497 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11697	16041-20000-02167	6600 N TOPANGA CANYON BLVD #1084G	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only for exiting retail space. Total area: 724 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11698	17041-10000-01250	833 E IMPERIAL HWY	90059	15	087A209   366	6072013022	RD2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	33.93118	-118.25989	NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE = 12.2KVA INCLUDING 2 CENTRAL INVERTERS(SOLIVIA - SOLIVIA 5.2TL & 7.6TL), WITH 50 MODULES(LDK 280P-24).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11699	17041-20003-40205	6927 N REMMET AVE #C	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	Revisions to approved set of plans.  Plans updated to match to (N) service configuration.  (((05/10/2018 Changes to an approved set of plans. All changes have been clouded. PV system has be redesigned. System size is 3.3 kWac and consists of (1) inverter and (9) modules. *****Previous Work Description*****Plan check for solar pv system, roof-mounted array on 3-unit apartment.3kW ungounded system. (9) 280W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11700	15041-10000-09094	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM			PC Info Complete	07/16/2015 12:00:00 AM	PIN	33.92817449	-118.43220714	PC POWER AND ENERGY, TI 24. CONTAINMENT AREA NEW MCC. WITH NEW 5 DEVICES AND TOTAL AREA FOR OUTDOOR LIGHTING 840 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11701	18041-10000-34808	22744 W ROSCOE BLVD	91304	12	192B097   470	2013003004	P-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.21922	-118.62266	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11702	13041-20000-05254	777 S FIGUEROA ST 17th Flr	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			PC Approved	02/28/2013 12:00:00 AM	ADDRESS	34.04828	-118.26116	Change to lighting and receptacles to an existing office space in a high-rise building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11703	13041-20001-35198	3415 N GREEN VISTA DR	91436	5	159B133   182	2287010070	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.13243	-118.49905	"(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.  "" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11704	13041-10000-01216	17710 W ROSCOE BLVD	91325	12	192B129   324	2101001001	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.22072	-118.51902	NEW SHELL BUILDING LIGHTING AND POWER. single story . type vb - non-sprinklered	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11705	16041-10001-25122	2501 S WEST VIEW ST	90016	10	123B181   758	5049008056	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM			Reviewed by Supervisor	08/04/2016 12:00:00 AM	ADDRESS	34.03352	-118.34817	Fee expedite per applicantPV2. NEW ROOFTOP SOLAR SYSTEM ON EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE IS 13.3 KW AC(62) MODULES-SOLARWORLD SW 260 POLY(62 ) ENPHASE M215(1) 125A LOAD CENTER*Solar clearance is approved under 16041-10000-25122	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11706	11041-20000-08518	19030 W VENTURA BLVD	91356	3	174B121   461	2163021021	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	05/09/2011 12:00:00 AM	ADDRESS	34.1723	-118.54808	massage planet energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11707	16041-20000-25281	445 S FIGUEROA ST 11TH FLOOR	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. 11TH FLOOR. 6639 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11708	17041-20001-31878	16620 W STAGG ST	91406	6	189B137   108	2205009079	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.21302	-118.49616	Revisions to approved plans.  Relocation of main PV distribution and upsizing of wires for voltage drop performance.  (((Plan check for solar pv system, roof-mounted on commercial building.336kW ungrounded system [(5) 60kW + (1) 36kW inverters](1,311) 340W pv modules. Line side tap.BUILDING PERMIT # 17016-20000-29565)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11709	19041-20000-27657	18145 W CHARDON CIR	91316	5	165B125   112	2184013018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.15042	-118.53011	addition of (2) tesla ESS rated 5KW each to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11710	18041-10000-17852	14650 W ROSCOE BLVD	91402	6	192B149   408	2210010011	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.22135	-118.45172	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11711	10041-10000-02347	12200 W OLYMPIC BLVD 4th floor	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	09/18/2010 12:00:00 AM	ADDRESS	34.03195	-118.45506	TI - 4th floor remodel for shopzilla.  Permit is for new ckts on existing panels and lighting.  Area of remodel is >30,000 sq. ft.  P/C is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11712	12041-10000-13400	1224 S BEVERWIL DR	90035	5	132A167   219	4330024036	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM			PC Approved	06/08/2012 12:00:00 AM	ADDRESS	34.0554	-118.39891	Plan check for energy and emergency lighting. Occupancy load is less than 99. 750 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11713	19041-20000-36662	22111 W ERWIN ST	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.18299	-118.60932	PV2. Plan check for Pv roof mounted system, PV system size: 27.84KW DC, 24.8KW AC CEC with 64 PV Modules and 2 inverters(14.4KW and 9.0KW)Note: This is 12 Buildings on 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11714	19041-10000-00070	4933 N BALBOA BLVD	91316	5	168B133    66	2258018900	[Q]PF-1XL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.16032	-118.50131	PC for replacing existing fire alarm system. scope includes 22 devices and 1 fire alarm control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11715	18041-10000-33767	3211 S LA CIENEGA BLVD	90016	10	123B173  1686	4205035008	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.02942	-118.37217	Changes to approved set, under  16041-10000-28393 / E16LA03135. Changes include addition of photo cells and relocation of EV panel. note changes under clouded areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11716	14041-20000-06482	19961 W HEMMINGWAY ST	91306	3	189B113   721	2106003105	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.21413	-118.56867	Roof mounted PV system with size 3.5 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11717	15041-10000-28999	333 S GRAND AVE 18TH&19TH	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	ALTERATIONS IN EXISTING OFFICE ARAEASPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11718	17041-20002-16715	10604 N LOUISE AVE	91344	12	207B133   736	2695005007	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.26264	-118.51085	Revisions to approved plans.  Change to roof layout of modules.  Sheets S1, S1.1, and S2 only.  $0 plan check fee due to State Senate Bill SB 1222.(((pv1install roof mounted pv system sized 11.4kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11719	18041-10000-29176	23341 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	01/02/2019 12:00:00 AM		Issued	01/02/2019 12:00:00 AM	ADDRESS	34.15746	-118.63414	Plan check for power and energy of existing building.  Change of use from office to medical office.  TI to include new offices, ADA restroom, X-ray room, No invasive procedures. - TOTAL AFFECTED AREA 2126 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11720	17041-10000-10193	3320 W ADAMS BLVD	90018	10	123B189   718	5052015035	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.03243	-118.3204	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 151900 SQ FT. INDOOR/OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11721	12041-20000-16235	4700 W SUNSET BLVD	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01, 1913.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.09788	-118.29194	Addtion of lighting to indoor parking lighting system on the ground level, and installation of new sign.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11722	13041-20000-30234	15505 W ROSCOE BLVD	91343	6	192B145   365	2654028027	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.22156	-118.47097	Change to lighting in an existing low-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, No Emergency lighting per the applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11723	16041-20000-29296	1985 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.06159	-118.20463	TI TO AN EXISTING COMMERCIAL BUILDING (USC PSC LOBBY).  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHTING.  TOTAL SQUARE FOOTAGE 1804.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11724	16041-30001-45298	658 E 89TH ST	90002	9	096A207   212	6042009021	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2017 12:00:00 AM			PC Approved	03/16/2017 12:00:00 AM	ADDRESS	33.95551	-118.26317	03/16/2017 Changes to an approved set of plans. Changes have been made to the module model and the inverter module. System size has remained the same. *****Previous Work Description*****Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11725	08041-10001-26496	914 S GRAND VIEW ST	90006	1	130-5A201  25	5136005022	R4-1	Central	Westlake	MacArthur		2095.10	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.05365	-118.281	(((4/2/2014- CHANGES MADE TO APPROVED SET OF PLANS. CHANGES MADE TO T24 ONLY. CHANGED ONE FIXTURE TO LED)))Plan check power and energy for a church.  New 800A service, new MS, new panels, and ckts.  3-story including basement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11726	10041-20001-07771	5601 N DE SOTO AVE MOB II-FL 1-5	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.17126	-118.58861	Revision to approved plans. Plan check for Delta 4.1, installing additional (2) circuits to existing panels	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11727	13041-10000-26107	380 WORLD WAY #T50R-S2R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of led sel-illuminated signs on the external walls of a the tenant space Kitson on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11728	12041-20002-18799	147 N LARCHMONT BLVD	90004	4	138B189   757	5515019020	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	03/20/2013 12:00:00 AM	ADDRESS	34.07437	-118.32384	Changes to previously approved set of plans under 12041-20001-18799. Plan check for energy and emergency lighting.energy plan check gym. place	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11729	17041-20000-40743	1926 E 7TH PL	90021	14	124-5A217 332	5166017005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM			Reviewed by Supervisor	11/22/2017 12:00:00 AM	ADDRESS	34.03343	-118.23298	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from warehouse to theater/tenant improvement. Total lighting area = 5,501 sq. ft.Note: Building application has been generated under 17016-10000-03724	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11730	18041-10000-42738	4600 W COLORADO BLVD	90039	13	162B205   273	5593018903	PF-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Info Complete	07/18/2019 12:00:00 AM	ADDRESS	34.14094	-118.27314	INSTALLING A NEW 600 AMP MCC WITH SEVERAL MOTORS AND LOADS IN CLASS I DIV 2 AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11731	15041-10000-10275	900 N ALAMEDA ST 1st floor	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.05855	-118.23671	For a data center, (2) new 800A distributionboards, (2) new 300kVA XFMRS, and (12) new 225A panel boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11732	15041-10000-14117	1209-1215 S BEDFORD ST	90035	5	132B169   835	4332019033	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			05/20/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.05537	-118.38074	PLANCHECK FOR POWER AND ENERGY. NEW 21 UNIT APARTMENT BLDG. 5 STORIES. BLDG PC: 13010-30000-02593	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11733	15041-20001-36727	7715 N WOODHALL AVE	91304	12	189B093   665	2027030014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	34.21108	-118.63715	"**Fee expedite***GROUND MOUNTED SOLAR SYSTEM (3'-6"" HIGH MAX, 10' X 55')8.265 kW system(29) modules: SW285(1) inverter: FRONIUS 7.6Building permit already approved."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11734	15041-10000-16824	4570 W COLORADO BLVD	90039	13	162B205   118	5593018015	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.14078	-118.27277	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS  TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQURE FOOTAGE 16,130.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11735	19041-10001-08992	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Info Complete	07/18/2019 12:00:00 AM	ADDRESS	34.18421	-118.60617	Change to approved set by modifying the lighting and power plan. changes includes adding and removing fixture, electrical equipment, and modifying the panel schedule detail. Single line also being updated with new fault current and voltage drop, and T24 also being revised. All changes under clouded area associated with delta-6 and 7 only. (((TI IN A GROCERY STORE. CHANGE OF USE FROM RETAIL TO MARKET. PLAN CHECK FOR POWER & ENERGY. TOTAL AREA: 34,000 SQR FT. OTHER RELATED PERMITS = SHELL: 18041-10K-43843, SERVICE UPGRADE: 19041-20K-04168BUILDING: 19016-10K-07097)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11736	15041-10000-38977	801 S GRAND AVE STE 425	90013	14	129A209   267	5144020***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	PIN	34.0462287	-118.26018882	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 4451	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11737	13041-20000-17448	9301 N TAMPA AVE Space 92	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	T24 FOR RETAIL SPACE #92. TOTAL SQRFT: 3303. REMOVED FIXTURE 'F' FROM THE LIGHTING PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11738	19041-20000-07119	13687 W CHASE ST	91331	6	195B157   635	2640025002	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.23049	-118.43058	PV1.  Install 5.8 kW DC / 7.6 kW AC roof mounted grid tied PV system with 9.8 kWh energy storage system.  (20) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11739	18041-20000-09123	2800 S CRENSHAW BLVD	90016	10	123B185  1058	5051008019	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.03095	-118.3349	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,110 sq. ft.Note: Building permit has been issued under 17016-40000-13747	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11740	19041-10000-48213	16204 W BERTELLA DR	91436	5	168B137   644	2284016022	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM			Reviewed by Supervisor	11/27/2019 12:00:00 AM	ADDRESS	34.15396	-118.48639	VOID [EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 7.56KWdc (7.6KWac) USING 24 QP315 MODULES, 24 SE P400 POWER OTIMIZERS & 1 SE-7600H-US CENTRAL INVERTER. ESS TESLA POWERWALL.CONNECTED TO A 200 AMP EXISTING SERVICE.***** APPLICANT RECEIVED SEPARATE PLAN CHECK AND PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11741	10041-10000-18881	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	C2-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.04338	-118.26581	Ti in an existing locker room for lA clipper in Staples Center. Plan check is For energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11742	16041-10001-28398	1522 N HIGHLAND AVE	90028	13	147A185    37	5547020040	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.0987	-118.33847	PC FOR POWER AND ENERGY FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA A CHANGES. CHANGES TO LIGHTING DESIGN, ADDED NEW CIRCUITS AND REFEED ANOTHER BUILDING. PERMIT TO BE ISSUED UNDER THIS APPLICATION FOR ADDED WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11743	13041-20000-05364	6605 N FALLBROOK AVE	91307	3	180B097   311	2038040015	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.18874	-118.62363	Install new 600 ampere distribution boards to supply remodeled tenant space of existing building.  Plan check for power, T-24 and emergency lighting plan check.  The new switch board is supplied from an existing distribution board in the existing sprouts receiving area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11744	19041-10000-12480	400-450 WORLD WAY APM-Core	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Issued	07/24/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	FULL PC FOR POWER AND ENERGY FOR LAX. ADDITION TO TERMINAL 4 - TERMINAL VERTICAL CORE (TVC 4.5).  SCOPE OF WORK WILL INCLUDE REMOVE PARTIAL OF EXISTING TERMIANL 4 AND TERMINAL 5 TO CREATE SPACE FOR THE NEW TVC 4.5.  SCOPE INCLUDES PROVIDING ELECTRICAL INFRASTURE TO NEW APM CORE IN BETWEEN TERMINAL 4 AND 5. NEW DISTRIBUTION BOARDS, NEW LIGHTS, AND CIRCUITS. B#19014-10000-01416	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11745	15041-20000-19289	7604 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.20872	-118.46479	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 3.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11746	15041-20003-02895	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	08/24/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 25. Plans were changed to reflect field changes. Changes include the addition of branch circuits.*****Previous Work Description*****08/10/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 22. Changes include the recalculation of short circuit current values for all equipment to reflect actual available short circuit current.*****Previous Work Description*****Changes to approved set.  PC at request of inspector.  Emergency lights and exit signs are to be connected to normal circuit instead of inverter (with 90 min battery backup unit equipment).    **********    TENANT IMPROVEMENT FOR BUILD OUT OF NEW OFFICE & SHOWROOM WITHING (E) CORE & SHELL BUILDING.  FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.  PC IN ACCORDANE TO 2008 ENERGY DUE TO DATE OF BUILDING SUBMITTALSQUAREFOOTAGE FOR WAREHOUSE UNCONDITION SPACE NOT INCLUDED IN FEES TO BE ADJUSTED AT LATER TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11747	16041-20000-19456	10250 W CONSTELLATION BLVD STE 1250	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/03/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	I TO AN EXISTING COMMERCIAL BUILDING(HR).  ADDING NEW CIRCUITS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK IN SUITE 1250.  TOTAL SQUARE FOOTAGE 5400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11748	16041-10001-25272	17350 W SUNSET BLVD BUILDING-AB	90272	11	126B117   516	4415018016	C2-1VL, [Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Apartment			04/13/2017 12:00:00 AM			PC Approved	04/13/2017 12:00:00 AM	ADDRESS	34.04043	-118.55311	Changes to approved set of plan, changes to secondary connection from without fuse to with fuse version, and the changing the feeder size related. Plan check only.changes clouded as delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11749	12041-20000-19863	19854 W BARBERRY LANE	91356	3	162B113    98	2180021005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2012 12:00:00 AM			Plans on Hold	09/21/2012 12:00:00 AM	ADDRESS	34.13977	-118.5667	New ground mounted P.V. system (10.08KWdc).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11750	18041-10000-39005	1100 S SAN PEDRO ST A-12	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.03515	-118.25194	PLAN CHECK FOR T24 ONLY, T.I. TO (E) RETAIL. TOTAL AREA 3,309 SQ.FT (B# 18016-10000-08613)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11751	14041-20000-13813	13284 W VAUGHN ST	91331	7	213B157   316	2524024001	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	PIN	34.28134357	-118.42244479	PV1Install roof-mounted solar array on SFD. System size: 3.87kW(18) EnPhase M215-60-240-S22 microinverters(18) Canadian Solar CS6P 250P pv modulesNew main panel upgrade under separate permit	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11752	16041-10000-28512	12574 W WINGO ST	91331	7	204B161   484	2537011011	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2016 12:00:00 AM			Corrections Issued	08/11/2016 12:00:00 AM	ADDRESS	34.2544	-118.4072	PV1 SFD TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM WITH 40 MODULES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11753	18041-10000-48912	11620 W WILSHIRE BLVD #100,105	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.03	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.05021	-118.45963	Full plan check of existing medical office space being converted to a dermatology facility. Area under the scope of work includes: exam room, office area, lobby, X-ray room, and restrooms. Total area approx 7890 sf , new loads area added to (E) panelboards and (E) dist. board.((B# 18016-30000-33243))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11754	16041-10000-40212	1320 E 7TH ST #529	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	TI TO OFFICE SPACE. NEW FURNITURE AND NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11755	18041-10000-44955	6949 S LA TIJERA BLVD	90045	11	102B173   180	4103003011	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	33.97541	-118.37433	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11756	12041-10000-01954	20146 W VIA MEDICI	91326	12	219B113    42	2701041005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.29458	-118.5723	Plan check 8.385KW roof mounted photovoltaic system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11757	16041-10001-29267	6526 N GROSS AVE	91307	12	180B093   569	2036023023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.18906	-118.64026	EXPEDITE FEESPV1 SFD TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 40 MODULES IN TOTAL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11758	17041-20000-07713	20725 W SESNON BLVD #246	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Expired	05/05/2024 12:00:00 AM				pv1install roof mounted pv system sized 4.8kw interconnected with msp.  standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11759	12041-20000-20727	1609 S WESTWOOD BLVD STE A	90024	5	129B153   154	4324026024	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.05258	-118.43966	Plan check for power and emergency lighting. Dental Office. 1123 sqft. Suite A. Existing service and panel A; all loads to panel A are new.  Not a state licensed office, NOT checked for OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11760	16041-10000-02567	2095 S WESTWOOD BLVD	90025	5	126B153    75	4323003023	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.04532	-118.43317	T-24, CHANGE OF USE FROM BEAUTY PARLOR TO MASAGE PARLOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 942	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11761	13041-10002-09939	1439 N POINSETTIA PL 1-39	90046	4	147B181   777	5548019023	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			10/15/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.09717	-118.34858	((10/15/2014- CHANGES MADE TO APPROVED SET. REMOVED CAR LIFT ADDED 2 SUMP PUMPS))FULL PLAN CHECK FOR POWER AND ENERGY ON A 39 UNIT APARTMENT. 1600 AMP SERVICE.  1 TYPICAL UNIT PANEL. NOTE TO PLAN CHECKER: FIRE ALARM VARIANCE WILL BE FILED AT A LATER DATE, PHOTOMETRICS AND TITLE 24 CALCULATIONS WILL BE PROVIDED AT A LATER DATE CONTACT EMAIL .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11762	11041-20001-08624	189 S THE GROVE DR Ste H80	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM			PC Approved	10/04/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	Plan check only. Delta 9 only revision to approved plans. Changes to T24 calculation and lighting layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11763	11041-20000-17585	3611 W CADMAN DR	90027	4	154-5A203  17	5592005001	R1-1	Central	Hollywood	Greater Griffith Park	YES	1882.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.11918	-118.274	Plan check 9.87KW roof mounted photovoltaic system single family dwelling. Permit for PV system and upgrade 400A service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11764	10041-20000-15712	16045 W FOOTHILL BLVD BLDG C	91342	7	228B141   223	2603009036	[Q]C2-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.32166	-118.48062	PLAN CHECK T-24 ENERGY FOR LIGHTING IN EXISTING STORAGE FACILITY-  BLDG. C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11765	17041-20000-02771	9227 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.23663	-118.38075	Plan check for power only. Install new 5000A service for Waste Management landfill facility. Reconnect existing equipment. Install new MCCs and grinder skids. Project is located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11766	17041-10000-18823	10324 N BALBOA BLVD	91344	12	204B133   143	2684012047	C2-1VL, R3-1-RIO	North Valley	Granada Hills - Knollwood, Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Granada Hills South		1114.00	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.25831	-118.50213	PC for energy only, Outdoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 30,225 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11767	19041-20000-46168	1320 N LAKE SHORE AVE	90026	13	141A209   702	5419031013	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1974.20	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	04/19/2022 12:00:00 AM	ADDRESS	34.07876	-118.2599	Plan check for power only, load and equipment installed Title 24 energy on is under separte plan check(19041-20000-44910).Plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11768	19041-10000-41152	12518 W RIVERSIDE DR	91607	4	168B161   475	2357032006	(Q)C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Closed	12/29/2022 12:00:00 AM	ADDRESS	34.15741	-118.40628	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11769	11041-10001-10026	3060 S CRENSHAW BLVD	90018	10	120B185   804	5051029029	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM	ADDRESS	34.02579	-118.33489	REVISIONS TO PERMITTED SET OF PLANS ( CORE AND SHELL). DWP HAS INCREASED THE AVAILABLE SHORT CIRCUIT CURRENT TO 63KA RESULTING THE UPGRADE OF THE AIC RATING OF THE SWBD AND MAIN PANEL FOR FRESH AND EASY STORE AND THE HOUSE PANEL. PANEL B FOR THE BANK IS REMOVED AND SINGLE INE SHOWS STUB-UP CONDUIT. Core & Shell for a commercial Bldg. EPC is for Power & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11770	14041-10001-12964	1235 E VIENNA WAY	90291	11	111B149   596	4242013006	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM			PC Approved	05/24/2014 12:00:00 AM	ADDRESS	34.0007	-118.4541	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 18.87 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTERS AND WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11771	09041-20002-24723	15301 W LANARK ST	91406	6	189B145    41	2654037029	R4-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Apartment			11/17/2011 12:00:00 AM			PC Approved	11/17/2011 12:00:00 AM	PIN	34.2183683	-118.4669973	"This is a supplemental application for the fees generated in the original application under Submittal 2.  This application is just to allow the applicant to pay for the additional plan check fees.  Submittal 2 pay period in the original application will be deleted and all the itms in the final pay period in the original application will be deleted and entered under inspection in the original application.  <<<<<<<<< NEW 87-UNIT ""AFFORDABLE SENIOR HOUSING"", 4-STORY TYPE V-A 1 HR OVER 1-LEVEL BASEMENT PARKING GARAGE-TYPE 1A <THIRTY ONE(31) LOW INCOME UNITS>. Variance to separate fire alarm submitted 12/30/09.>>>>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11772	16041-10000-45452	1909 E 7TH PL	90021	14	124-5A217 288	5166016016	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.03373	-118.23356	Tenant improvement of (E) wharehouse to make existing restroom accessible. New partitions to include new work area and janitor's closet. New walk in cooler.  Remodel exterior front entrance for accessibility. No change of existing number of parking on site. See comments	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11773	13041-10000-22459	1010 N SIGSBEE AVE	90744	15	033B217   264	7428023033	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Closed	09/30/2015 12:00:00 AM	ADDRESS	33.78437	-118.23446	New 350 HP water injection and 20 hp pump for petroleum storage facility.  Hazardous classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11774	12041-10001-04678	10201 W PICO BLVD BLDG 26	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM			PC Approved	04/26/2012 12:00:00 AM	PIN	34.05182951	-118.41257696	PLAN CHECK REVISION TO APPROVED PLANS MARKED DELTA 6. RELOCATE DC DISCONNECT FROM INVERTER PAD TO INSIDE BUILDING 26.***PLAN CHECK FOR NEW ROOF MOUNTED 231.8KW PHOTOVOLTAIC SYSTEM ON FOX STUDIOS BUILDINGS #26 AND BUILDING #29. PLAN CHECK UNDER #11041-10000-25537. SATCON INVERTER LOCATED IN BUILDING #29. 532 MODULES ON BUILDING #26 AND 434 MODULES ON BUILDING #29. (2 0F 2)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11775	14041-20000-05381	10131 N GENESTA AVE	91325	12	204B133   380	2694018023	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.25492	-118.50475	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.6 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 35 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11776	14041-20000-23954	2945 S LA SALLE AVE	90018	8	120B193   333	5053017024	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.02773	-118.3055	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3KW INTERCONNECTED WITH MNSP.(20) HYUNDAI M250MG MODULES(20) ENPHASE 215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11777	14041-10001-05596	2528 S FIGUEROA ST	90007	9	121-5A203  26	5124027016	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.02852	-118.27554	((CHANGES MADE TO APPROVED SET, CHANGING SOME LIGHT FIXTURES))pc for t24 only. permit to be pulled at EPC counter only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11778	16041-10001-01907	1830 W SLAUSON AVE Store 1039	90047	8	105B193  1872	6001001023	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	33.98779	-118.31204	10/06/16Changes to an approved set of plans. All changes are clouded under delta 6. Changes include adding a neutral conductor for the power distribution section (PDS, 3wire to 4 wire system), and adding customer meter on the single line diagram. ((((((New 210 kW fuel cell system, interconnected to (E) service 480/277V. Fuel Cell utility interactive.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11779	16041-10003-16336	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 9. CHANGES INCLUDE TITLE 24 LIGHTING FIXTURES/PHOTOMETRICS, ADDITION OF 2 NEW DISTRIBUTION BOARDS (1000A & 400) WITH NEW CONNECTED LOAD (ALL HVAC), AND ADDITION AND RELOCATION OF ELECTRICAL COMPONENTS.   SEE NOTES FOR PREVIOUS PERMITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11780	17041-10002-02863	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	"PC ONLY. CHANGES TO APPROVED SET DUE TO CHANGE ON THE FIELD.  CHANGING FIXTURE TYPE IN ""VIRGIN AMERICA"" STORAGE ROOMS FROM TYPE ""C"" TO TYPE ""A""REVISION TO TI-24 FORM TO REFLECT CHANGES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11781	12041-20000-10047	1925 W TEMPLE ST #112	90026	13	136-5A207  43	5157024040	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	2084.02	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM			PC Approved	05/02/2012 12:00:00 AM	ADDRESS	34.06987	-118.26627	T24 lighting plan check for remodeled space #112.  Existing permit number 12041-20000-07913.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11782	18041-20000-04532	6800 S AVALON BLVD	90003	9	102B205   234	6007019019	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Closed	10/30/2020 12:00:00 AM	ADDRESS	33.97824	-118.26497	(2) new services 1200 amp each serving an existing commercial building.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11783	15041-20000-27871	4903 N RHODES AVE	91607	2	168B165   241	2356027004	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.15959	-118.40324	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (16) modules, and (16) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11784	12041-20000-13595	7355 N CLEON AVE	91352	2	186B173   824	2410017008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.20447	-118.36827	Enphase system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11785	17041-10000-12034	633 W 5TH ST 9TH Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only in existing space T.I. office space high-rise building. Total area: 13,125 sq ft.B#17016-10000-09016	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11786	19041-20000-01962	12506 N MARVA AVE	91344	12	219B129   280	2601050016	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.29795	-118.51833	Installation of 13.5 kWh energy storage system, backup gateway, and 125 A critical load backup panel.  (E) 6.17 kW PV system on site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11787	18041-20000-22842	9401 N CORBIN AVE 1st-2nd Floor	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.24143	-118.56249	Plan check for Title 24 Energy only in existing space T.I. office space new lighting and receptacle. Total area: 2943 sq ft.B#18016-20000-15638	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11788	12041-10000-01975	2005 W PICO BLVD	90006	1	129A201   229	5136023031	(T)(Q)CM-1	Central	Westlake	Pico Union		2098.10, 2098.20, 2243.10	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Expired	02/26/2014 12:00:00 AM	ADDRESS	34.04702	-118.28177	Plan check fire alarm system for installation new two story office building with two levels subterranean parking.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11789	17041-10000-28661	5201 W WILSHIRE BLVD	90036	4	135B181   921	5507023029	[Q]C4-2-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.06237	-118.34314	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY. TOTAL SQUARE FT 12000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11790	17041-20003-32165	23251 W CHASE ST	91304	12	192B093    64	2005014028	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.22364	-118.63404	[ 11/21/17  CHANGES TO APPROVED SET. ADDING (2) FUSED DISCONNECTS TO THE ENERGY STORAGE DEVICE AND (2) DISCONNECTS TO THE INVERTER OUTPUT.]]Plan check for roof-mounted solar pv system with AC coupled battery backup system.10.4kW ungrounded pv system [(1) 6.6kW + (1) 3.8kW].(34) 325W pv modules. (2) 5kW Tesla Powerwall 2s.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11791	17041-10000-44521	9136 N SEPULVEDA BLVD	91343	7	198B145   337	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.23685	-118.46732	Remove HID fixtures and replace with new LED fixtures  T-24 only.TOTAL SQ.FT 153475	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11792	17041-10001-44844	500 WORLD WAY DELTA 2017-OAL	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM			PC Approved	07/27/2018 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC FOR CHNGES TO APPROVED SET UNDER DELATA 15. SCOPE INCLUDES REMOVAL OF STORAGE SPACE  LEVEL 2 ZONE P15  ABOUT 220SQ.FT AND REMOVAL OF 3 FIXTURES WITH T-24 FORMS UPDATED. THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11793	10041-20000-05808	6724 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.11795	-118.33953	intalling emergency lighting and exit sign in four story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11794	19041-10000-35127	327 N LECOUVREUR AVE	90744	15	030B209  1031	7424004022	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.77398	-118.25566	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11795	16041-20000-18231	9339 N COLLETT AVE	91343	12	198B141   324	2671016005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Expired	06/27/2018 12:00:00 AM	ADDRESS	34.2405	-118.48402	PV1.  Install 6 kW roof-mounted PV system.  Simplified central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11796	17041-20000-33062	9255 W SWALLOW DR	90069	4	150B169  1256	5561009023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.10504	-118.39002	New single-family dwelling with a 600A 240/120V single phase service.Note: Combination building permit under 13010-20000-04372 (electrical permit fees included).  Permit issued under this application for inspection of electrical service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11797	16041-10000-39304	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	BRAND NEW BUILDING. PC FOR POWER AND ENERGY. THIS IS NEW SOCCER STADIUM WITH 5KV MEDIUM VOLTAGE SERVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11798	15041-20002-28568	3498 N ALANA DR	91403	5	159B141    45	2280017043	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM			PC Approved	10/23/2015 12:00:00 AM	ADDRESS	34.13547	-118.47963	10-23-2015 Change to an approved set of plans. Changes include remove 1 inverter(SMA SB7700 TL) and remove 2 modules. Total remaining modules: 52, and 1 inverter SMA SB7700 TL {{{{{{{PV1. Install roof mounted PV system sized 15.4 kW. Interconnected with main service panel.(56) Kyocera KD 265 Modules(2) SMA SB7700 TL InvertersNote: Fee is $0 due to SB 1222}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11799	16041-20000-21235	10352 W DIAMOND ST LOT 17	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11800	18041-10000-27608	18355 W ROSCOE BLVD	91325	12	192B125   495	2786022044	RA-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Issued	07/24/2018 12:00:00 AM	ADDRESS	34.22093	-118.53329	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11801	16041-20000-12933	10537 N GLENOAKS BLVD	91331	7	207B165   231	2537001028	[T][Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.26131	-118.39881	Nonstructural interior T.I. at (E)office area on 1st floor & mezzanine.  5,478 sq. ft. Plan check for energy.  Emergency egress lighting existing to remain per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11802	14041-20000-03113	2956 S NORMANDIE AVE	90007	8	120B197   322	5054007001	[Q]R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.02756	-118.30006	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11803	14041-20001-10657	18518-18526 W PARTHENIA ST	91324	12	195B125   900	2785004031	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	34.22805	-118.53686	Change from previously approved plans.  Changes service panel to Siemens type, AIC series rating, and feeder size.  No change in load calculation.  Plan check for power only.Note: Permit is under the original application.*****Previous Description*****PC FOR NEW SERVICE UPGRADE. 800A SERVICE PROVIDING POWER FOR 2 TENANTS. 400A EACH. PLAN CHECK FOR POWER ONLY. MAIN BREAKER TO BE TYPE LC SERIES RATED WITH DISTRIBUTION BREAKERS TYPE FA. SERIES RATE TO 100KAIC MAXIMUM. PER MANUFACTURE SPEC SHEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11804	15041-10000-03116	1401 N LONDONDERRY PL	90069	4	147B169   915	5559010012	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Expired	02/28/2017 12:00:00 AM	ADDRESS	34.09556	-118.38046	PV1, 6.875KW DC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE(25)  MODULES (25)MICRO INVERTER ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11805	19041-20000-41042	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11806	15041-20000-15157	19791 W BAHAMA ST	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.23359	-118.5643	Title 24. TI to existing warehouse building with offices. Plan check for energy only including including emergency. Total sqft. 16,352	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11807	12041-20001-30030	21431 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM	08/12/2013 12:00:00 AM		Permit Expired	09/07/2015 12:00:00 AM	ADDRESS	34.25739	-118.59841	Changes to approved set of plans. Changes to lighting, addition of panel NLB and rerouting of many circuits on panel LA. Plan check for power and energy.Plan check for power and energy. Ti to Ralphs #710. 20615 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11808	15041-10001-02422	8450 W 3RD ST	90048	5	138B173   801	5511032037	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/23/2015 12:00:00 AM	ADDRESS	34.07306	-118.37487	Change to an approved set by adding a fixture (LT13) on the floor plan of the dinning area. (((TENANT IMPROVEMENT IN EXISTING RETAIL STORE;AN ORIGINAL PLANS WERE PERMITTED ON SEPARATE APPLICATIONPermit wa sobtained on separate applicationTITLE 24 ONLY)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11809	16041-10000-38752	300 S GRAND AVE 4th Flr	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	TI TO CORRIDOR SPACE ON 4TH FLOOR. LIGHTING UPGRADES. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11810	14041-20000-04893	728 W WOODLAWN AVE	90291	11	108B149  1125	4237011001	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	33.99064	-118.45599	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7 KWdc USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 3 STRINGS/ INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11811	13041-20003-30768	7192 W ESTEPA DR PV1	91042	7	198B197   121	2562021007	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.24227	-118.28902	"][][""$0 permit fee is due to the 2012 Senate Bill No. 1222"". CHANGES MADE TO APPROVED SET OF PLANS; DOWNSIZING MCB FROM 200A TO 150A, DOWNSIZING GROUNDED AND UNGROUNDED CONDUCTORS, AND UPSIZING SERVICE PNL. SEE ATTACHED LOAD CALC. ALONG W/ APPROVED SET ][][New 18.639kw Photovoltaic System on the roof of an existing single family dwelling.  System is UNGROUNDED. ""$0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11812	14041-10000-25690	12518 W FIELDING CIR	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	33.97836	-118.41209	PLAN CHECK FOR FIRE ALARM SYSTEM FOR APARTMENT COMPLEX WITH MULTIPLE BUILDING WITH MULTIPLE ADDRESSES. THIS IS BUILDING 6 OF 7. ALL BUILDING UNDER ONE SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11813	15041-10000-01395	1025 W ELYSIAN PARK DR	90026	1	141B213     3	5415005906	OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.08589	-118.24622	Plan check for Title 24 only. Project consists of the addition of lighting to picnic area restrooms. Total lighting area = 302 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11814	13041-20000-17756	18240 W ACRE ST	91325	12	195B125   737	2769021028	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			Reviewed by Supervisor	08/06/2013 12:00:00 AM	ADDRESS	34.22986	-118.53091	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.5 KW. USING TRANSFORMERLESS INVERTER. 28 MODULES. 2 CENTRAL INVERTER. 3 STRINGS. AND 2 STRINGS. (change in design. new plan check required. this application to be terminated))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11815	13041-10001-29740	19373 W VICTORY BLVD STORE 1656	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.1878	-118.5556	(((4/10/2014- CHANGES MADE TO APPROVED SET [DELTA 5]. REVISED SOME LIGHTING IN THE LOADING AREA. DID SOME ARCHITECTUAL CHANGES AS WELL. THIS IS A PLAN CHECK ONLY APPLICATION.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11816	11041-20000-16548	14731 W RAYEN ST 1-42	91402	7	195B149   247	2651012028	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Apartment			08/05/2011 12:00:00 AM	09/20/2011 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.23197	-118.45487	fire alarm 62 units apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11817	19041-10000-07924	716 S SAN PEDRO ST	90014	14	126A213   220	5146033056	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	09/26/2020 12:00:00 AM	ADDRESS	34.0402	-118.247	REMOVE INDOOR HID FIXTURE AND REPLACE NEW LED FIXTURE TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11818	13041-10000-03100	9533 N AMESTOY AVE	91325	12	201B133   591	2692018024	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2013 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	ADDRESS	34.24411	-118.50695	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE OF 10.78KW. USING CENTRAL INVERTER. 44 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11819	09041-10019-24270	380 W WORLD WAY NORTH-CONCOURSE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	CPlan review for RFI FILES for the Bradley West Gates:	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11820	16041-20001-06429	16344 W HORACE ST	91344	12	210B137   677	2680019036	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM			Reviewed by Supervisor	03/08/2016 12:00:00 AM	ADDRESS	34.27003	-118.4884	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (32) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11821	19041-30000-06422	9301 N TAMPA AVE Suite 181	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 4,014 sq. ft.Note: Building application has been generated under 19016-30000-05064	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11822	12041-20000-24772	10960 W WILSHIRE BLVD 1030	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.058	-118.44597	T-24 and emergency lighting plan check for suite 1030.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11823	16041-10000-39893	9631 N TOPANGA CANYON PL	91311	12	201B101   441	2746016069	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.24518	-118.60544	PC FOR T24 ONLY. REMOVE E HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA (INDOO& OUTDOOR) 29950 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11824	19041-10001-09386	8240 N BABCOCK AVE	91605	2	192B161   169	2308004014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM			PC Info Complete	06/25/2019 12:00:00 AM	ADDRESS	34.22111	-118.40698	*zero permit fee per AB-1414/SB-1222*(Plan check only) Revision to approved plan to show the location of equipments as installed on field.<<NEW ROOFTOP SOLAR SYSTEM CONSIST OF 23 MODULES (Q-CELL 305) , 23 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 7.015KWdc and 6KWac>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11825	19041-10000-23596	20730 W PRAIRIE ST	91311	12	198B109    81	2748002048	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Closed	12/28/2021 12:00:00 AM	ADDRESS	34.24073	-118.58534	Energy plan check for removing HID fixtures and replace with new LED fixtures in a commeical building with a total lighting area of 102875-SQ FT. (outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11826	11041-10000-12865	4700 W WILSHIRE BLVD	90010	4	132B185    28	5090008031	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	07/25/2011 12:00:00 AM	ADDRESS	34.06183	-118.3324	Install new fire alarm panel to supply existing devices thru modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11827	17041-10000-29188	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.09818	-118.35187	PC FOR FIRE ALARM IN A COMMERCIAL BUILDING. TOTAL DEVICE COUNT > 150	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11828	19041-10000-23319	1256 W 7TH ST	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.05216	-118.26774	NEW PANELBOARD AND CIRCUITS FOR BUILDING FACADE LIGHTING/SINAGEPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11829	19041-20000-15670	4920 N VAN NUYS BLVD pv2	91403	4	169-5A151  47	2248007139	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.15995	-118.4485	PLAN CHECK FOR NEW PV SYSTEM ON EXISTING APARTMENT BUILDING. SYSTEM SIZE IS 20.44KW DC/20KW AC/18.68KW AC CEC. SCOPE OF WORK INCLUDES (56) ASTROHALO 365W PV MODULES WITH (28) P730 OPTIMIZERS, A SE20KUS INVERTER, AND A  30KVA TRANSFORMER.PLAN CHECK DONE UNDER PERMIT NUMBER 19041-20000-06630	N	Y	Express Permit	06/10/2024 12:00:00 AM
11830	13041-10000-29410	5835 N DONNA AVE	91356	3	174B121   777	2156012036	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			Verifications in Progress	12/03/2013 12:00:00 AM	ADDRESS	34.17647	-118.54771	PV1.  Install 4 kW DC roof-mounted photovoltaic system interconnect with main service panel.  Using Fronius IG PLUS v. 11.4.  55 modules: Hanwha HSL60P6-PB-4-250TW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11831	17041-20001-42736	8401 N VAN NUYS BLVD #15	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.22308	-118.44896	03/27/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta C. Changes have been made to reflect field conditions and installation.*****Previous Work Description*****T-24, PC for energy only. TI for an existing commercial space. Scope includes adding new lights for restrooms and corridor space within an existing tenant mall space. Total affected area is 4767 Sq. Ft. B#17016-10000-21521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11832	12041-10000-29663	1955 W SLAUSON AVE	90062	8	108B193  1312	5005018029	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	03/18/2013 12:00:00 AM	PIN	33.98940747	-118.3127929	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS ON A REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11833	10041-10000-19990	10551 W WILSHIRE BLVD 1-87	90024	5	135B153   557	4360032***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.06253	-118.43326	title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11834	18041-20000-37312	20667 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.29296	-118.58467	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11835	14041-20000-01135	15642 W LARKSPUR ST	91342	7	222B141    87	2604011025	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.30747	-118.47242	pv1 single family dwelling total system size 3kw ac using transformerless inverter nonstandard plan with power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11836	10041-20001-17665	609 S ST PAUL AVE 1-350	90017	1	130-5A207  24	5143025030	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			11/19/2010 12:00:00 AM			PC Approved	12/02/2010 12:00:00 AM	ADDRESS	34.05337	-118.26134	Changes from previously approved plans.  Change from EMT conduits to PVC conduits encased in concrete.*****Plan check for new installation of fire alarm system in a 350 units apartment building*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11837	17041-10000-14731	29050 N WESTERN AVE	90275	15	021B193    39	7445004242	(Q)C2-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	PIN	33.75477294	-118.30875089	PC FOR PARKING LOT LIGHTING REPLACEMENTpermit issued under separate permit. #17041-40000-06645	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11838	18041-20000-40089	16810 W MAGNOLIA BLVD	91436	5	171B133   367	2259002008	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Re-Activate Permit	04/17/2019 12:00:00 AM	ADDRESS	34.16481	-118.49948	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11839	19041-20000-49549	6559 S BRYNHURST AVE	90043	8	102B185   120	4006020025	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM	11/04/2020 12:00:00 AM		Issued	11/04/2020 12:00:00 AM	ADDRESS	33.979	-118.33392	PC FOR INSTALING A NEW 1200 AMP 208/120 3 PHASE 4 WIRE SERVICE WITH DISTRIBUTION EQUIPMENT, CAR CHARGER, (26) NEW UNIT PANELS, ELEVATOR AND LIGTHING. TOTAL AREA 22436 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11840	15041-20000-07437	12914 W WINGO ST	91331	7	201B161   368	2624010017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.24934	-118.414	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11841	16041-20001-42216	3364 N STONERIDGE LANE	90077	4	159B149   307	2278032016	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.13187	-118.45838	expedite per applicant.pv1install roof mounted pv system sized 15kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11842	19041-10000-35518	6000 W 6TH ST 1-4	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.06462	-118.35943	POWER PC FOR TEMP POWER FOR  TEMPORARY TRAILERS. SERVICE SIZE 800A, 480V, 3PH, 4W (E). CRCUITS INSIDE THE THE TRAILERS ARE NOT PART OF THE SCOPE. SINGLE POINT  POWER CONNECTIONS TO TRAILERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11843	13041-10000-31786	311 E CULVER BLVD	90293	11	096B149   305	4116009055	[Q]C4-1D	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.95984	-118.44755	NEW FIRE ALARM SYSTEM TO 3-STORY COMMERCIAL BUILDING ( + ROOF ) . SPRINKLERED SYSTEM; WITH 28 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11844	16041-10000-26992	930 N FIGUEROA TER	90012	1	136-5A213 137	5406025058	R4-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.06712	-118.24383	$0 permit fee due to senate bill 1222 from 2012PV2, INSTALL ATION OF NEW 132480 W DC, ROOF-MOUNTED SOLAR ARAY ON A COMMERCIAL BULDING. (414) MODULES: THAISUN TSG72-320P(8) INVERTERS: FRONIUS USA SYMO 15.0-3 208 V***APPLICANT WOULD PREFER TO BE CONTACTED BY EMAIL.***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11845	18041-10000-42061	2450 N LILLYVALE AVE	90032	14	139-5A237  94	5220034029	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.07562	-118.16432	REPLACING AN EXISTING 230KW GENERATOR WITH A NEW 600KW, 750KVA GENERTAOR AND NEW TRANSFER SWITCHES TO PROVIDE POWEWR TO 3 BUILDINGS: B402, B403 & B406 AT GRIFOLS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11846	11041-10001-06790	6554 W HOLLYWOOD BLVD	90028	13	148-5A187 188	5547015017	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	34.10141	-118.3329	REVISIONS TO PERMITTED SET OF PLANS- A TYPE 0F LUMINAIRE REOLACED WITH TRACK LIGHTING; CIRCUITS ARE REASSIGNED TO DIFFERENT LOADS.((((((((((Change of use from retail to restaurant ~ 2576 S.F. remove uppermitted mezzanine( INTERIOR ONLY ) **	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11847	19041-20000-26951	350 S GRAND AVE ste 3570	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	ti to an existing commercial building(high rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11848	14041-20000-31028	12039 N HAVANA AVE	91342	7	216B149   379	2611017004	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.28898	-118.45435	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 10.4 DC.(32) SUNPOWER 327 MODULES, (1) SMA SB3000, (1) SMA SB6000Note: Solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11849	13041-10000-20788	23729 W STRATHERN ST	91304	12	189B089   102	2020007052	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.21515	-118.64473	PV1.  Install 7.1 kW roof-mounted solar array, interconnect into main service panel.  {Microinverters: Enphase M215} {33 modules: YINGLI YL245P-29B}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11850	17041-10001-41821	1347 W 19TH ST	90732	15	012B193   907	7460013006	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2973.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	33.72692	-118.30691	EXPEDITED FEESNEW SOLAR MOUNTED PV SYSTEM USING CENTRAL INVERTER WITH THE ADDITION OF TESLA 2.0 BATTERY. (1) INVERTER (6)MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11851	15041-10001-14620	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 35 CHANGES TO PERMITTED SET OF PLANS: REVISED SCHEDULES FOR THOSE PANELS FROM WHICH CIRCUITS WERE REMOVED; ADDED NOTE 12 ON SHEET ED120-7FCHANGES ARE CLOUDED ON THE PLANS(((((((((UTILITY CONNECTIONS BETWEEN THE PLBS, RAMP EQUIPMENT, AND THE TERMINAL. WORK UNDER PACKAGE 4. TITLE 24 FORMS TO BE SUBMITTED. FULL PC, PC FOR ENERGY AND POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11852	12041-10000-01892	850 W CESAR E CHAVEZ AVE	90012	1	133-5A213  53	5407003036	C2-2D	Central	Central City	Historic Cultural		2071.00	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.06167	-118.24558	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING CREDIT UNION BANK. PERMIT FOR NEW PANELS, BRANCH CIRCUITS, AND EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11853	17041-30000-41178	12078 W SUMMIT CIR	90210	2	156B165    22	2382017016	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.12707	-118.40069	Plan check for PV roof mounted system. Total sysem size: 19.8kW with 55 AC modules connected to 300A Service MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11854	12041-10000-16113	6136 W 85TH PL	90045	11	096B165   503	4107037004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	33.96032	-118.39281	Plan check for new roof mounted 5.886 KW Photovoltaic System for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11855	19041-20000-01183	1782 N ORANGE DR	90028	13	150B181   645	5548004010	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			Corrections Issued	01/10/2019 12:00:00 AM	ADDRESS	34.10395	-118.34162	Power and lighting for new single story office building.  Outside feeder supplying 225A panel for building. Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11856	13041-10000-09184	5035 W COLISEUM ST	90016	10	117B177  1130	5046038025	C2-1, CR-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.01852	-118.35483	RENOVATION OF SMALL STORAGE SPACE. 6 FIXTURES. NEW LIGHTING. PER SUPERVISOR REQUEST, APPLICATION APPROVED WITH SET OF PLANS. INSTALLED WATTAGE REMAINS < 0.6WATTS/SQ FT. PLANS APPROVED SIGNED BY C-10 CONTRACTOR. TOTAL AREA 486 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11857	14041-10000-25694	12550 W FIELDING CIR	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	33.97815	-118.41197	PLAN CHECK FOR FIRE ALARM SYSTEM FOR APARTMENT COMPLEX WITH MULTIPLE BUILDING WITH MULTIPLE ADDRESSES. THIS IS BUILDING 2 OF 7. ALL BUILDING UNDER ONE SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11858	16041-10000-40882	535 W EL SEGUNDO BLVD	90248	15	081B201   252	6132002022	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Apartment			11/18/2016 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.91658	-118.284	PC FOR METHEANE DETECTION SYSTEM LEVEL 5  FOR  NEW four-story 75-units apartment.*. 65 FA DEVICES AND 2 CONTROL PANELS. B# 16010-10000-02632	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11859	17041-30000-41217	12652 W ALBERS ST	91607	2	174B161   646	2346009009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.17025	-118.40894	Plan check for PV roof mounted system with battery back. total number of modules 25 and 8.6 kW with 13.5k Battery power wall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11860	16041-10000-22867	350 E 118TH ST	90061	15	084B205   742	6083020003	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	33.92633	-118.26776	PV 1 roof mounted solar system installtion to a single family home. Installing (1) central inverter rated at 7.6 kw. and 19 solar modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11861	13041-10000-33290	750 E 12TH ST #2	90021	14	123A211    50	5132012032	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	11/27/2013 12:00:00 AM	ADDRESS	34.03273	-118.25185	PLAN CHECK FOR TITLE 24, ENERGY ONLY. AREA 1364 SQ FT. REMVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11862	14041-20000-25879	13435 W DESMOND ST	91331	7	213B157   667	2523017017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.27756	-118.42545	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11863	19041-20000-32065	20809 W ACORN CIR UNIT #167	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.29453	-118.58692	Plan check for PV roof mounted system, System size: 3.15KW with 9 PV Modules and 9 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11864	17041-20001-01582	7780 W TORREYSON DR	90046	4	159B173   643	5570014010	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.12857	-118.36833	expeditepv1install roof monted pv system sized 14kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11865	11041-10000-19134	1356 W ALLISON AVE	90026	1	138A211   119	5405021033	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	09/09/2011 12:00:00 AM	ADDRESS	34.07275	-118.25157	"T.I. TO AN EXISTING RESTAURANT.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.Original submittal incorrect address ""1354 Sunset Bl."" replaced with correct address ""1356 W. Allison Ave"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11866	13041-10000-13000	2018 E CESAR E CHAVEZ AVE	90033	14	129A223   128	5183001020	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM	05/17/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	ADDRESS	34.04854	-118.21218	"PLAN CHECK FOR FIRE ALARM SYSTEM IN A MIX USED  BUILDING. 13 DEVICES AND 1 FIRE ALARM CONTROL PANEL.Code Enforcement Bureau has issued an order. This parcel is eligible for issuance of a 30 day time limit permit (including Building, Electrical, HVAC and Plumbing) with a work description as follows. ""COMPLY WITH DEPARTMENT ORDER effective date 07/02/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".Investigation fee due. Code Enforcement Order to Comply issued with effective date 07/02/2012"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11867	13041-10002-33753	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM			PC Approved	03/31/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	((((3/31/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  REVIONS TO THE LIGHTING FIXTURES NOTED DELTA 3 ON THE PLANS.MASTER PERMIT UNDER 13041 10001 33753EPC for T24 for Tom Bradley LAX project. Install a new 300KVA Xformer & a new 1200 Amp panel & Conduit stubs for (5) future tenant. No new load is added except 4 new lighting circuits. All FUTURE electrical installations require complete electrical plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11868	17041-20000-03491	919 S ALBANY ST	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.04913	-118.27045	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE IN LOYOLA LAW SCHOOL.  11065 SQFT. 1ST AND 2ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11869	19041-10000-13408	11341 N BRAINARD AVE	91342	7	210B177    24	2529014011	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.27595	-118.36371	plan check for title 24 only for change of HID to LED lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11870	19041-10000-06470	1707 N WESTRIDGE ROAD	90049	11	135B137   526	4426002014	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM			PC Info Complete	02/22/2019 12:00:00 AM	ADDRESS	34.06412	-118.4939	Existing single family house.  Service upgrade to 600Amp, 120/240V, 1Ph @ 32KAIC and Replacing 6 existing panels with 4 @ 22KAIC & 2 @ 10KAIC rating panels and Reconnecting to Existing loads in house. No New Load added.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11871	12041-20000-25663	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM			PC Approved	10/26/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check only for load calcs per inspector's request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11872	12041-10000-08926	11525 W DONA DOROTEA DR PV1	91604	2	156B169   137	2381023001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2012 12:00:00 AM			PC Approved	05/07/2012 12:00:00 AM	ADDRESS	34.12689	-118.38556	6.27 KW ROOF MOUNT, 33 PANELS & (1) INVERTOR FOR AN EXISTING SINGLE FAMILY RESIDENCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11873	14041-10000-00602	1230 S SANTEE ST	90015	14	124-5A209 143	5145027039	M2-2D	Central		Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.03552	-118.25778	Remove HID light fixtures and replace with fluorescent fixtures in 952 sq. ft. retail space.  Space accessible only from Santee Alley pedestrian-only zone entrance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11874	14041-20001-11426	5652 N VANTAGE AVE	91607	2	174B165   538	2340026044	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/14/2014 12:00:00 AM	ADDRESS	34.17364	-118.3975	Expedited plan check per applicant request.PV1.  Install 3.00 kW roof-mounted PV system, interconnect with main service panel.  (12) modules.  Transformerless inverter: SolarEdge SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11875	16041-10000-29274	1632 W COLORADO BLVD	90041	14	162A225    95	5689017003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.13927	-118.20215	Plan check Title 24 only in existing space T.I. retail lighting and recptacle. Total area:1,132	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11876	19041-10000-51966	434 S VERMONT AVE	90020	13	135B197   582	5077003026	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.06646	-118.29145	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS & REPLACE INDOOR/OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11877	14041-10001-03885	7565 W SHORE CLIFF DR	90045	11	099B157   570	4114004048	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	33.96509	-118.4304	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 4 kW DC roof-mounted solar array on a two-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) Modules: CANADIAN SOLAR CS6P-250PX.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11878	18041-10001-06389	8160 W MANNIX DR	90046	4	150A175   189	5556004019	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.10593	-118.37	Change to approved set by adding an additional AC disconnect on the floor plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11879	12041-20000-17437	8300 N VALLEY CIRCLE BLVD #B	91304	12	192B089    72	2005021017	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.21953	-118.64648	T.I. for dental office.  Install branch circuits and lighting. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11880	16041-10001-33465	1263 S WESTCHESTER PL	90019	10	129B189   916	5081020022	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM			Reviewed by Supervisor	09/29/2016 12:00:00 AM	ADDRESS	34.04776	-118.31885	Expedite per applicant request(((((Plan check for PV roof mounted system. System size: 15.2kW with 48 modules and 2 inverters(7.6kW ) connected to load center.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11881	18041-10000-15490	1516 S PONTIUS AVE	90025	5	129B149    66	4324019004	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.04962	-118.44666	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11882	14041-20000-05227	5832 S WEST SEAGLASS CIR	90094	11	102B157   400	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	33.97362	-118.41945	ROOF-MOUNTED,PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11883	15041-10001-03340	9758 N BURNET AVE	91343	7	201B145   360	2656007007	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2015 12:00:00 AM			PC Approved	02/25/2015 12:00:00 AM	ADDRESS	34.24814	-118.46293	Supplemental application for expedite feeInstallation of roof mounted solar PV array on existing single family dwelling.  Total system size = 8.4 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11884	17041-20002-30269	21730 W DEVONSHIRE ST	91311	12	204B105   294	2747015007	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM			PC Approved	10/05/2017 12:00:00 AM	ADDRESS	34.25707	-118.60282	10/05/2017 Changes to an approved set of plans. Changes have been made to the PV module count. Inverter size has remained the same.*****Previous Work Description*****Plan check for solar pv system, roof-mounted on commercial building.10kW ungrounded system. (34) 380W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11885	18041-10002-34803	521 N ROCKINGHAM AVE	90049	11	135B137   472	4406004001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	34.06464	-118.49068	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE CHANGE OF MODULE FROM 325 TO 330. _______________________________________________NEW 13.98 KW ROOF MOUNTED PV SYSTEM WITH 43 PV PANELS AND 54 KWH ENERGY STORAGE SYSTEM CONNECTED TO THE EXISTING 600 AMP SERVICE ON A SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11886	17041-10000-11312	11134 W SATICOY ST	91352	2	186B173   316	2315014039	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.2083	-118.37322	PC for energy only, Outdoor Title 24. Removing HID existing fixtures with new LED fixtures. Area: 12,600.Total of 8 fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11887	18041-20000-32876	21631 W HEATHERLEE LANE	91311	12	210B105    70	2722004023	RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.27088	-118.60112	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11888	16041-10000-07393	9625 N AQUEDUCT AVE	91343	12	201B141   403	2671008023	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.24553	-118.47405	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.02KWdc / 10.0KWac. (40)MODULES-CANADIAN SOLAR CS6P-255P(1)INVERTER-SOLAREDGE SE10000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11889	14041-10001-17723	730-736 S LOS ANGELES ST	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			09/03/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.04254	-118.25109	Changes to approved set.  Change of connection point for fire pump to utility power.   Changes to sheets E101, E200, and E201 - clouded changes only.  (((plan check for power and energy. high rise. Existing building. not methane. REMODELED 6-STORIES  72 UNITS APARTMENT BUILDING. BLDG#14016-10-11297:ADAPTIVE REUSE. Changes on plan include updates to load calcs and T24 and address.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11890	13041-10001-35767	1755 N HIGHLAND AVE 5TH FLOOR	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.10323	-118.33897	PERMIT IS UNDER IS APPLICATION.Changes to approved set, delta-1 modifications.  Minor changes to lighting plan layout in fitness room.   (((PLANCHECK FOR T24 ENERGY ONLY FOR FITNESS ROOM IN THE 5TH FLOOR OF LOEWS HOTEL. HIGH RISE. 1740 SQFT, EMERGENCY LIGHTING.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11891	12041-20000-28459	671 S MATHEWS ST	90023	14	124-5A223 156	5185027019	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.03522	-118.21322	PV-1. Plan check for single family dwelling. Enphase micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11892	15041-10000-36056	111 E UNIVERSAL HOLLYWOOD DR 29TH FLR	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	FULL PC, TO AN (E) COMMERCIAL HIGH RISE BUILDING. SCOPE OF WORK INCLUDES A NEW 800 AMP DISTRUBUTION BOARD BEING FED FROM AN (E) 4000AMP SWITCHGEAR.Note to Inspection: 30-day peak demand report has been submitted and reviewed. Peak demand=1050 amps, Inspector to verify on the field.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11893	12041-10000-08121	2214 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.03782	-118.44071	"REMODELING OF EXISTING RETAIL T-MOBILE STOREPLAN CHK IS FOR TITLE 24PERMIT FEES IS UNDER ""INSPECTION"" FEE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11894	17041-10001-40964	12908 W DISCOVERY CK	90094	11	102B157   349	4211027***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	33.97306	-118.42032	Change to approved set by adding (4) modules to the PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11895	16041-20000-33058	20600 W VENTURA BLVD	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.16715	-118.58204	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HAIR SALON. 1931 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11896	19041-10000-52731	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	06/17/2020 12:00:00 AM		Permit Finaled	06/21/2021 12:00:00 AM	ADDRESS	34.06188	-118.30486	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE INCLUDES ONE NEW FIRE ALARM PLAN, THREE NEW RPS, AND 237 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11897	16041-20000-31435	11964 W CREST PL	90210	2	156B165   156	2382020009	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM			PC Info Complete	10/24/2016 12:00:00 AM	ADDRESS	34.12351	-118.39922	ADDITION OF  1-STORY AND BASEMENT  TO (E) 2-STORY SFD.  PLAN CHECK ONLY FOR POWER.  NEW 600 A 120/240V SERVICE.BUILDING PERMIT UNDER 16014-10000-00429	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11898	17041-10000-24031	8601 S LINCOLN BLVD 190	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	33.95939	-118.41943	PC for T24 only for new lights for restuarant TI. Total affected area is 1304 sqft. Building PC 17016-40000-13850.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11899	12041-10000-14138	264 S ALEXANDRIA AVE	90004	10	135B197   129	5518014023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.06937	-118.29772	PROPOSED MAJOR INTERIOR REMODEL AND CONVERT EXISTING  4-DWELLING UNIT APARTMENT  TO A 17-UNIT APARTMENT HOTEL (transient).  FIRE SPRINKLERS THRU-OUT.  SEE COMMENTS.SERVICE AND PNELBO5RDS ARE EXISTING PLAN CHK IS FOR TITLE 24 FOR COMMON AREAS(HALLWAY AND STAIRWAYS. AND EXTERIOR HARDSCAPE LIGHTINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11900	16041-10000-13758	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.01366	-118.28294	T-24, TI TO A LOUNGE ROOM. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1748.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11901	19041-10000-32980	8236 N REMMET AVE	91304	6	192B153  1041	2213002023	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.21856	-118.60015	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11902	18041-10000-05340	8756 N CANBY AVE	91325	12	195B125   664	2769025020	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.23029	-118.53467	REPLACE OUTDOOR HID LUMINAIRES WITH LEDTYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11903	19041-30000-14278	801 S FIGUEROA ST 11th Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the common area corridors on the 11th floor. Project scope is a tenant improvement. Total lighting area  = 1,680 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11904	13041-10001-26973	3425 E ALICE ST	90065	1	147A219   247	5454027004	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.09646	-118.22612	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. TRANSFORMER LESS INVERTER. UNGROUNDED SYSTEM. SYSTEM SIZE: 3kW.(12) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PV1-3.0-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11905	12041-10000-26279	6922 W HOLLYWOOD BLVD	90028	13, 14	147B181   197	5548006011	C4-2D-SN, M2-2D	Central	Central City, Hollywood	Central Hollywood, Downtown Los Angeles		1901.00, 2063.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.10137	-118.34103	Plan check T24 Energy outdoor lighting for patio area at existing Coffee Beans & Tea Leaf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11906	13041-20000-01876	5080 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2197.00, 2360.00, 2362.02	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.02028	-118.35491	Chages to approved set of plans. Temporary power installation for construction. Please reference 12041-20000-09896. Ralphs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11907	14041-10002-22089	3550 W 6TH ST	90005	10	135B197  1072	5502031014	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.06341	-118.30006	07/26/16Changes to an approved set of plans. All changes are clouded under delta 11. Changes include adding/replacing lighting fixtures for outdoor roof, removing one inverter and relocating the second inverter, revisions to AIC ratings for existig distribution boards, and adding exit and emergency lights on the roof.Note: Permit is paid under PCIS#14041-10000-22089(((((PLANCHECK FOR POWER AND ENERGY.  CONVERSION OF AN EXISTING 5 STORY OFFICE/PARKING BUILDING TO ADAPTIVE RE-USE (89 UNITS W/ STUDIO, 1, 2 AND 3 BEDROOM UNITS ALONG WITH 3 LIVE/WORK UNITS). THE EXISTING PARKING ON THE 1ST FLOOR TO REMAIN, FLOORS 2-5 ARE CONVERTED TO 92 UNITS.  EXISITING SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11908	17041-10000-36605	2010 W 62ND ST	90047	8	105B189  1017	6001020015	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	33.98325	-118.31394	PC FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL BUILDING. SYSTEM SIZE 19.8KWDC / 23KWAC. SCOPE INCULDES 66 PANELS WITH SINGLE INVERTER. ADDITIONAL SYSTEMS ARE INSTALLED ON SAME ROOF.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11909	18041-20000-46785	555 S FLOWER ST Floors 16--18	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI to (E) commercial office space in highrise building.  Plan check for power and energy.  63,700 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11910	10041-10001-01485	7500 N CHAMINADE AVE	91304	12	186B093    52	2027005009	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM			PC Approved	12/08/2010 12:00:00 AM	ADDRESS	34.20673	-118.63673	REVISIONS TO APPROVED SET OF PLANS: WILL USE EXISTING SWBD ; NEW BUILDING  WILL BE SUPPLIED FROM A SET OF FEEDERS FROM  EXISTING SWBD; CONCESSION BLDG SUPPLIED FROM  THE NEW BUILDING DIST BWD(N) performing arts building on (E) high school campus.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11911	16041-10000-28326	6375-6377 N VAN NUYS BLVD	91401	6	180B149   927	2241004001	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Expired	10/12/2016 12:00:00 AM	ADDRESS	34.18646	-118.44899	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (T-MOBILE).SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1664 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11912	17041-20000-40938	10839 W KLING ST	91602	2	168B173   674	2421022042	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			11/14/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.15578	-118.36704	Plan check for power and energy. Project site is a 3-story, 6-unit apartment building. Work includes a 600-amp service.Note: Building permit has been pulled under 15010-20000-00616	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11913	14041-10001-22608	1212 N LA COLLINA DR	90069	4	144B165   175	4392016032	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.09283	-118.39552	PLAN CHK FOR FIELD CHANGES: ORIGINAL SWBD REPLACED WITH A MAIN /METER BOARD AND ORIGINAL SWBD USED AS A DISTRIBUTION BD((((((((Remodel of (E) 4060 square feet single family dwelling.  Rewiring of house and new 600A service and service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11914	19041-10002-04281	604 W C ST	90744	15	027B205   232	7417019921	OS-1-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Issued	04/24/2019 12:00:00 AM	ADDRESS	33.77218	-118.26861	DELTA 2 CHANGES TO AN APPROVED SET. ADDITION OF A WIRELESS CELLULAR COMUNICATION PANEL. original scope ((PC FOR REPLACING (1) OBSOLETE METHANE SYSTEM MONITORING PANEL WITH NEW MODEL))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11915	18041-20001-38478	18815 W SHERMAN WAY	91335	3	183B121   109	2118025005	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	06/18/2020 12:00:00 AM	ADDRESS	34.20128	-118.54323	Revisions to approved set.  (2) additional subpanels and additional loads added to system design.<<<Plan check for power and energy for renovation of (E) car wash.  New 800A 480Y/277V 3ph/4w service. Building permit under 18016-30000-30845.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11916	16041-10000-15739	4040 N EAGLE ROCK BLVD	90065	1	156A219   271	5472001071	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Info Complete	05/17/2016 12:00:00 AM	ADDRESS	34.12059	-118.22721	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2344 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11917	16041-10001-03575	5939 N TOPEKA DR	91356	3	177B121   726	2156014007	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.17832	-118.54628	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1. INSTALL 14.72 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(45) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTERS: SMA SB7700TL & SB5000TL-US-22>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11918	12041-10002-14929	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM			PC Approved	02/27/2013 12:00:00 AM	ADDRESS	34.21585	-118.47965	"((((CHANGED FEEDER ""1"", ""1D"", ""2"", ""2D"", ""3"", ""4"", ""5"", AND ""6"" FROM 600MCM TO 500MCM.)))))  (( Increase in couple feeder lenths, new two 65 kva 3 phase , three poles, no neutral need all motor loads.  addition of two refrigeration skids, removing two old ref. skids, in exiting one story bldg."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11919	17041-20000-25219	19630 W CANTARA ST	91335	3	192B117   923	2105002003	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.21901	-118.5612	PV1.  Install roof mounted PV system sized 9.6kW.  AC modules interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11920	13041-10000-09269	8850 N MEGAN AVE	91304	12	195B101   127	2010005032	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.2317	-118.6064	New roof mounted P.V. system with 11.772 KWdc for a 2-story single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11921	14041-10000-11078	6903 N LONGRIDGE AVE	91605	2	183B157   735	2327007059	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Expired	05/23/2016 12:00:00 AM	ADDRESS	34.19579	-118.42162	Install roof-mounted solar array, interconnected with main panel.  System size = 3 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11922	18041-10000-17344	189 S THE GROVE DR 3	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR TITLE 24 ENRGY ONLY FOR (E) ICE CREAM KIOSKTOTAL AFFECTED AREA  220 SQ. FT. ; COMPLY WITH DEPARTMENT ORDER effective date01/11/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11923	13041-10001-26345	16781 W KNOLLWOOD DR	91344	12	216B137   516	2609007020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.28482	-118.49635	][][]EXPEDITED PER APPLICANT REQUEST][][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A STANDARD PLAN; COMBINER BOX WILL BE USED. SYSTEM SIZE IS7.35KW DC WITH (30) MODULES: TRINA #TSM-245PA05.18(1) INVERTER: FRONIUS #IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11924	11041-10001-05310	2815 W JEFFERSON BLVD	90018	10	120B189   611	5051036043	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.10	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM			PC Info Complete	03/07/2012 12:00:00 AM	ADDRESS	34.02574	-118.32651	Suppl. Application. Changes to the lighting plan in a new laundry in existing building.  Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11925	18041-10000-22229	777 S SANTA FE AVE	90021	14	124-5A217 323	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT ON EXISTING PERMITTED ROOF TERRACE.  NEW CIRCUITS FED FROM EXISTING PANELBOARDS. SCOPE OF WORK 4219 SF TOTAL AREA:5616 SQ. FT (OUTDOOR).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11926	15041-10000-43538	5836 S MCCONNELL AVE	90094	11	102B161  1270	4211037026	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Issued	01/13/2016 12:00:00 AM	ADDRESS	33.97502	-118.41628	Full plan check for a new building under a single plan, located in the same job site of a Methane ZONE, consists of  (6) new stand alone buildings with (6) different addresses and application numbers; Each building is identical and has 4-story and 6 units supplied by a 600-Amp service;  All electrical work for the plan are identical to  reference building applicaton #15041-10000-27550 located at the same site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11927	18041-10000-27897	617 W 7TH ST Suite 1103	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.04779	-118.2571	TENANT IMPROVEMENT AT EXISTING OFFICE AREA ON THE 11TH FLOOR IN SUITE 1103.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11928	12041-20000-07079	1305 N GAFFEY ST Bldg.B	90731	15	021B197   135	7445002006	M1-1VL	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	08/29/2012 12:00:00 AM	ADDRESS	33.75593	-118.29257	1lighting circuit for Bldg. BRequest for Modification to separate Fire Alarm system filed. 12042-10000-00730- Level II Methane Gas Mitigation	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11929	14041-10000-12277	6600 N TOPANGA CANYON BLVD Suite #14	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI remodel of existing retail space. MEP work - title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11930	18041-10002-07828	1501 W SUNSET BLVD A;B;APTS	90026	13	139-5A209 235	5419027007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.07605	-118.2552	Changes to an approved set of plans, note changes on delta 4 only. changes include the revision of service entrance conductors and lighting change to surface mounted. _________________________________________________________________REMODEL AND CHANGE OF USE FROM 2-STORIES  OFFICE WITH ATTACHED GARAGE TO RESTAURANTS ON THE 1ST FLOOR AND 5-UNITS APARTMENTS ON THE 2ND FLOOR.FEE FOR SMOKE DETECTORS WERE NOT INCLUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11931	12041-20000-16649	1901 S AVENUE OF THE STARS # 700	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.05949	-118.41705	Install and relocate lights in existing office spaces.  Plan check for T-24 lighting plan check for two offices 724 and 725 in suite 700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11932	16041-10000-44950	2190 W 31ST ST	90018	10	120B189   574	5052024040	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.02636	-118.31478	PC for energy only; Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 30,950.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11933	17041-10001-26188	1431 W KNOX ST #300	90501	15	057B197   111	7351002029	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	33.85442	-118.29964	CHANGES TO APPROVED SET OF PLAN - CHANGES INCLUDE PANEL BOARD FEED AND REDUCTION OF LIGHTING LOAD, AND EQUIPMENT LOAD BASED ON FIELD CONDITIONS.ORIGINAL PERMIT #17041-10000-26188FULL PC FOR POWER AND ENERGY.  CHANGE OF USE FROM RETAIL TO A RESTAURANT IN A SINGLE STORY BUILDING.  REUSE EXISTING PANELBOARDS, AND PROVIDED NEW CIRCUITRY WITH NEW LOAD  < 200A.(B# 17016-40000-21056)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11934	16041-10000-25706	3411 S CRENSHAW BLVD	90016	10	120B185   977	5046001038	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.02516	-118.33536	Full pc for power and energy. Multi used building 5 story. 1st level basement and retail and 49 residential units in the above stories. Main service is rated at 3000 Amps 120/208V 3phase, 4wire. All new equipment. 9 Typical units. Building located in Methane Zone. Total sqft = 58910.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11935	13041-10000-33579	7824 N WHITSETT AVE	91605	2	189B165   765	2308014012	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.21286	-118.40508	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE5000A-US}]. [(18)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11936	14041-20001-01884	4012 N SUMAC DR	91403	4	162B149   191	2275006024	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.14293	-118.44937	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11937	19041-10000-18641	1506 S ABBOT KINNEY BLVD	90291	11	108B145  1494	4238005033	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/19/2020 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	33.99018	-118.46466	T-24. RENOVATION OF (E) RETAIL STORE IN (E) BIILDING FOR SAME TENANT.  NEW MILLWORKOPENING FOR NEW GLASS DOORS IN BACK OF SPACE/PATIO. TOTAL AFFECTED AREA IS 1134 SQ.FTNO CHANGE OF OCCUPANCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11938	10041-20000-16939	12135 W VICTORY BLVD	91606	2	180B165   697	2322006035	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1238.00	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM	08/26/2010 12:00:00 AM		Permit Finaled	01/06/2011 12:00:00 AM	ADDRESS	34.18684	-118.39792	LIGHTING IN RESTAURANT. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11939	19041-20000-30699	6800 S AVALON BLVD	90003	9	102B205   234	6007019019	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	02/20/2020 12:00:00 AM		Issued	02/20/2020 12:00:00 AM	ADDRESS	33.97824	-118.26497	FULL PLAN CHECK FOR OSHPD 3 TENANT IMPROVEMNT. PROVIDE NEW PANELS AND EQUIPMENTS TO EXISTING 600 AMP SERVICE. TOTAL AFFECTED AREA 9,950 SQFT. B#19016-20000-23396	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11940	15041-10000-40585	8413 W BLACKBURN AVE 1-25	90048	5	138B173   895	5511032061	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.07224	-118.37373	NEW FIRE ALARM SYSTEM TO A 25 UNIT, 4 STORY APARTMENT BUILDING. 115 FIRE ALARM DEVICES, 1 NEW FIRE ALARM PANEL AND A REMOTE POWER SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11941	16041-10004-45243	8654 N MASON AVE	91306	3	195B109   357	2781007024	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.22794	-118.57961	pc for changes to approved set of plans. changes clouded. checking for new module count. now only 20 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11942	15041-20001-37663	15127 W PLUMMER ST	91343	7	198B145    13	2656008014	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.24288	-118.46202	EXPEDITER PER APPLICANT REQUEST. ((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 16.125KWac. (75)MODULES-HANWHA Q CELLS Q.PRO-G3 265W (75)MICROINVERTERS-ENPHASE ENERGY M215-60-S2X(1)100A SUBPANEL))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11943	17041-10000-05778	718 S ALVARADO ST	90057	1	132A203   155	5141019003	C2-2	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Apartment			02/22/2017 12:00:00 AM			Corrections Issued	03/16/2017 12:00:00 AM	ADDRESS	34.05586	-118.27701	Plan check for power and energy in existing appartment building 38 units and 1 commercial space. Upgrade service to 800A. Total area: 9133 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11944	13041-20000-05654	19330 W PLUMMER ST	91324	12	198B117    73	2761037001	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.2426	-118.55515	Remodeled Ross Dress For Less.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11945	12041-10000-17399	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVEMENT IN OFFICES ON THE 24TH FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11946	17041-10000-07227	8659 N CORBIN AVE	91306	3	195B117   226	2782021021	C2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.22782	-118.56247	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 12125 SQ FT. INDOOR+ OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11947	15041-20000-21810	8379 N SALE AVE	91304	12	192B097   240	2004004011	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Expired	08/10/2017 12:00:00 AM	ADDRESS	34.22217	-118.61948	Installation of new roof mounted solar PV array.  Total system size = 11 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11948	17041-20000-34216	5670 W WILSHIRE BLVD 1100	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	12/16/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for energy only. TI to office suite 1100 in high rise building. New lighting (incl. emergency) - 13,311sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11949	17041-10000-24712	1259 W FLORENCE AVE	90044	8	102B197  1150	6014034030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	33.97475	-118.29784	PV 1. Single family dwelling on residential roof-top. PC for 7.8 KW rooftop solar. PC for 34 Axitec AC-265P modules and one Fronius Primo 7.8 central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11950	10041-10001-07749	888 S FIGUEROA ST BASEMENT	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM			PC Info Complete	04/28/2010 12:00:00 AM	ADDRESS	34.0465	-118.26225	Title 24 in the basement corridor.  Changing T12 to T8 lighting.  Enmergency lighting in place, Permit is existing.  This is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11951	12041-10000-16073	260 S LA BREA AVE	90036	5	135B181   125	5513023006	C2-1LD, [Q]C2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	03/18/2013 12:00:00 AM	ADDRESS	34.06965	-118.34383	Plan check for fire alarm. Ralphs store #39	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11952	12041-20000-03254	959 E 108TH ST	90002	15	090B209  1489	6051015032	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	PIN	33.9385509	-118.256657	New 90.2KW photovoltaic system on roof of mfg building.Note: Some device permitted under 10041-20000-22319.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11953	19041-10000-00467	16444 W ROSCOE BLVD	91406	6	189B137     4	2205003906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21987	-118.49574	"PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL WITH ""0"" NOTIFICATIONS DEVICES - PANEL IS ISTALLED FOR THE PURPOSE OF HEAT DETECTORS ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11954	16041-10000-43935	888 S FIGUEROA ST #620	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	34.0465	-118.26225	PC FOR OFFICE TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11955	12041-10000-07358	1733-1735 W COLORADO BLVD	90041	14	162A225    84	5669021026	C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.1396	-118.20486	NEW RESTAURANT. PLAN CHECK FOR POWER & ENERGY (PER APPLICANT'S REQUEST)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11956	18041-10000-06926	330-332 N PATTON ST	90026	1	135A209    35	5160009004	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			02/26/2018 12:00:00 AM	09/10/2020 12:00:00 AM		Permit Finaled	12/23/2022 12:00:00 AM	ADDRESS	34.06594	-118.25864	PC FOR POWER AND ENERGY. SCOPE INCLUDES ADDING A NEW 1600A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELBOARDS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 22891 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11957	17041-10000-14807	16935 W BIRCHER ST	91344	12	213B133   456	2610006002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.28112	-118.50045	PC FOR PV SYSTEM ROOF MOUNTED 7.6KW AC USING STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11958	13041-20000-20170	13042 W AETNA ST	91401	2	177B161   791	2331023042	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.18023	-118.41729	pv1 single family dwelling total system size 5.6 kw using 23 modules. central transformerless inverter. nonstandard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11959	16041-10000-40395	310 E FLORENCE AVE	90003	9	102B205   871	6022017024	[Q]CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	33.97455	-118.26901	Title 24 plan check.  T.I. to existing deli.  New lights, receptacles, and HVAC.  Total area = 2,925 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11960	18041-20000-06710	2601 N BOWMONT DR POOL HOUSE	90210										Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM	ADDRESS	34.11604	-118.39984	PLAN CHECK FOR POWER ONLY - POWER FEEDS FROM MAIN HOUSE PANEL SEE COMENTSPOOL HOUSE MAIN APPLICATION 18041-20000-06698	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11961	11041-20000-05749	5250 N LANKERSHIM BLVD 7TH  FLR	91601	4	171B173  1421	2350018090	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.16668	-118.37545	PLAN CHECK T24 ENERGY/EMERGENCY FOR TENANT IMPROVEMENT ON THE 7TH FLOOR EQAL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11962	14041-10000-21225	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	33.78054	-118.23195	VERIFY LICENSE NUMBER. PLAN CHECK FOR POWER ONLY. PROJECT: SUBSTATION 2 RELIABILITY UPGRADE PROJECT. VALERO REFINERY BUT SCOPE OF WORK IS LOCATED OUTSIDE OF HAZARDOUS LOCATION PER APPLICANT. SCOPE: REPLACE 4160V SWITCHGEAR SECTIONS. REPLACE TWO (2) EXISTING 480V , 2500KVA UNIT SUBSTATIONS WITH FOUR (4) NEW 480V , 2000KVA UNIT SUBSTATIONS. ALSO INSTALLING BUSWAY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11963	19041-20000-50466	13263 N WHEELER AVE UNIT 30	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS(ENPHASE IQ7PLUS)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11964	15041-20000-28531	6735 W FOREST LAWN DR 4th Floor	90068	4	165B185   196	5581028009	C1-1D-RIO	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.14466	-118.33917	Plan check for energy only. Remodel of bank offices. New receptacles and lighting (incl. emergency).  6,437sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11965	18041-10000-04613	11700 W NATIONAL BLVD	90064	11	120B153  1083	4250001026	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			Reviewed by Supervisor	02/15/2018 12:00:00 AM	ADDRESS	34.02237	-118.43891	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR AND EXTERIOR WORK .TOTAL AFFECTED AREA 5264 + APROX 3000 SQ.FTPLANCHECKER TO VERIFY OUTDOORS LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11966	19041-20000-39065	3150 W WILSHIRE BLVD EV	90010	10	132B197    39	5077010025	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2122.03	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.06163	-118.29086	Plan check for power only in existing building for install 43 EV Charging Stations, connected to existing Service, Electrical Equipment, conduit, conductors(Existing EV Infrastructure), load exceed 400A.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11967	16041-20001-00547	16836 W BOSQUE DR	91436	5	165B133   247	2291003005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.14957	-118.49954	Expedite per applicant request. ((((((Plan check for PV roof mounted system. System size: 15kW with 50 modules.)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11968	10041-20000-25582	10960 W WILSHIRE BLVD 14TH FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR OFFICE TI ON THE 14TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11969	18041-10000-06240	10835 W OXNARD ST	91606	2	177B173  1012	2414005010	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.17956	-118.36743	Full plan check for change of use from Retail to Dentist Office. New (1) 400A panel for new lighting and power, total area 2,906 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11970	11041-20000-15848	11845 W OLYMPIC BLVD #830-W	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	PIN	34.03325831	-118.45191172	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE TI #830-W IN HIGH RISE BUILDING. PERMIT #11041-30000-14207	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11971	11041-10001-23853	650 N LACHMAN LANE	90272	11	129B121   627	4419014038	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.04827	-118.54632	New Backup Battery system for a pv system.  (Modification to  original plan check)     HYbrid system<<<<ROOF INSTALLATION OF A 11KW PHOTOVOLTAIC SYSTEM>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11972	19041-20000-37510	5437 N SATSUMA AVE	91601	2	174B173  1318	2416012028	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.16971	-118.36764	Plan check for Title 24 only in existing space, change of use from wearhouse to entertainment production. Total area: 4878 sq ft. B#18016-30000-18942	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11973	16041-10000-28937	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.1504	-118.32742	Install 2 load interrupter switch 15 kV each at 4800 V. Replacement of 2 feeders, #2 AWG, increase insulation level to 15kV.(sup. rev. by A.F.)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11974	17041-10000-34432	13570 N ELDRIDGE AVE	91342	7	228B157   742	2511002005	CR-1XL-CPIO	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.31872	-118.42539	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PC FOR PV SYSTEM USING TOTAL OF 126 MODULES AND 2 CENTRAL INVERTERS. TOTAL RATED 40KW AC. NET METER IN LOAD SIDE CONNECTION.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11975	18041-20001-10335	10508 W WOODBRIDGE ST	91602	4	165B177   593	2424013011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.14874	-118.35957	Expedited plan check fee.(((PV1.  Install 15.2 kW roof mounted grid tied PV system on single family dwelling and detached structure.  (50) modules with (2) 7.6 kW rated string inverters using power optimizers.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11976	16041-20000-13022	13630 W VAN NUYS BLVD 106-107	91331	7	207B157  1196	2646006025	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.2603	-118.42973	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/fire repair to (2) units (Units 106 and 107). Total lighting area = 1,970 sq. ft. Note: Building permit has been pulled under 15016-10000-21548	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11977	18041-10000-18819	6421 N GLORIA AVE	91406	6	180B141   881	2233014003	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.18728	-118.47945	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOAL SYSTEM SIZE IS 6.30KWdc / 7.60KWac  (18)MODULES-HYUNDAI HiS-S350TI(18)OPTIMIZERS-SOLAREDGE P370(1)INVERTER-SOLAREDGE SE7600H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11978	14041-20000-03295	17383 W SUNSET BLVD BUILDING B	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.03917	-118.55529	T24 FOR EXISTING BATHROOM. SCOPE OF WORK IN BUILDING B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11979	18041-20000-03609	1135 N MANSFIELD AVE 3RD FLR	90038	4	144B181   376	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Info Complete	02/01/2018 12:00:00 AM	ADDRESS	34.0918	-118.34057	PLAN CHECK FOR TITLE 24 ONLY FOR (INTERIOR OFFICE TI). TOTAL AFFECTED AREA = 8359 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11980	13041-20000-03250	9651 N ODESSA AVE PV-1	91343	12	201B137   656	2677006008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01, 1173.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.24618	-118.49187	Plan check for PV. SERVICE UPGRADE WILL BE INCLUDED IN INSPECTION FEE PERIOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11981	14041-10000-09896	16250 W STAGG ST	91406	6	189B137    72	2205004030	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.21301	-118.487	Title 24.  Remove HID light fixtures and replace with new fluorescent fixtures.Total area = 13785 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11982	14041-20000-22193	16426 W KNOLLWOOD DR	91344	12	219B137    59	2609016002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.29717	-118.49574	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.  PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.4KW INTERCONNECTED WITH MSP.(46) KYOCERA KD255GX-LFB3 MODULES(2) POWER ONE AURORA PV1-4.2 TRANSFORMERLESS INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11983	10041-10000-05305	618 S SPRING ST	90014	14	127-5A211  30	5144001018	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM			PC Approved	03/24/2010 12:00:00 AM	ADDRESS	34.04532	-118.25131	T-24 lighting plan check for Fire Pump Room.  Existing permit 10041-10001-04571.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11984	16041-10000-03930	1315 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Expired	03/12/2018 12:00:00 AM	ADDRESS	33.78944	-118.24745	PV1, INSTALL NEW 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON AN EXISTING APARTMENT BUILDING.(16) MODULES: CANADIAN SOLAR CS6P-260P(1) INVERTER: FRONIOUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11985	13041-10001-32308	6347 W WEIDLAKE DR	90068	4	153A187    13	5577034005	R1-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.11551	-118.32714	Expedited RSES plan check per applicant request.(((PV1, Install 7.42 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE6000A-US. 28 modules Suniva OPT2650-60-4-1B0.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11986	13041-10001-34203	12209 W WILSHIRE BLVD SUITE B	90049	11	126B145   232	4264026006	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Expired	01/11/2016 12:00:00 AM	PIN	34.04347531	-118.46880107	][]CHANGES MADE TO APPROVED SET OF PLANS; T24 PART 6 ENERGY ONLY; CHANGES IS TO REFLECT NEW LIGHTING CHANGES AND WIRE SIZE FROM MAIN SWITCH BOARD TO PANEL 'A' ; SCOPE OF WORK STILL  < 400A. PERMIT ALREADY PULLED ][][] pc for energy only. permit to be pulled at EPC counter. less than 400A. emergency lights installed. 1 story. Air Force recruiting office.changes on plans include addition of Occupancy sensors (watt stopper) to the two small offices and missing lights to calcs.INSTALL NON-BEARING PARTITION WALL TO ENLARGE & BUILD NEW OFFICES ON EXISTING TENANT IMPROVEMENT.  CHANGE OF USE FROM RETAIL SPACE TO OFFICE. NO CHANGE IN PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11987	19041-10000-16774	5458 W 76TH ST	90045	11	099B173   268	4127011019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	33.96873	-118.37576	(ePlan)  New 5.2 kW AC Roof Mounted Solar with w/ ESS. Install (1) 5.2 kW AC Inverter, (2) 13.5 kWh ESS, (18) Modules, ((1) New 200A Load Center. System conect to (E) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
11988	19041-20000-36512	18433 W ARMINTA ST	91335	12	189B125   434	2102015030	(T)R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.21396	-118.53493	PLAN CHECK FOR NEW PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 10.26 KW AC CEC. SCOPE OF WORK CONSISTS OF (36) PV MODULES, A 3.8 KW INVERTER, A 7.6 KW INVERTER, AND A 125A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11989	11041-20002-10621	941 E 2ND ST	90012	9	129A217   108	5163005001	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	ADDRESS	34.04727	-118.23375	PERMIT WAS ISSUED FOR 11 PANELS EXISTING SERVICE CONTRACTOR CHANGED THE SERVICE TO 600 AMPS THEN PLAN CHECK IS REQUITRED AND CIRCUITS ON PANELSNote: Permit for existing subpanels and branch circuits issued under 11041-20000-10621 and 11041-20001-10621.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11990	19041-20001-03607	5007 N AMIGO AVE	91356	3	171B121   562	2176014024	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.16118	-118.53944	Expedite per applicant request Plan check for PV and Battery back up system, PV system size: 17.08KW with 56 PV modules and 2 inverters(7.6KW) and 3 Energy storage system Tesla PowerWall 2.0 (9.8KWh)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11991	17041-20002-08719	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.17705	-118.6144	Revisions to approved set of plans - addition of visible AC disconnect and utility meter socket.  Approval for delta-5 revisions only on sheet PV-4.  (((PV2. GROUNDMOUNT SOLAR SYSTEM. SYSTEM SIZE: 70 KW. (223) WINAICO WSP 300 MODULES(3) SYMO 12.0 (3) SYMO 10.0)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11992	16041-10000-02685	1700 W OLYMPIC BLVD	90015	1	130-5A203 345	5137017014	C4-1	Central	Westlake	Pico Union		2095.20	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	07/21/2017 12:00:00 AM		Issued	07/21/2017 12:00:00 AM	ADDRESS	34.0497	-118.27604	5 STORY, 149  GUSTROOMS   HOTEL BUILDING OVER  ONE LEVEL OF SUBTERRANEAN PARKING GARAGE & GROUND FLOOR PARKING, LOBBY, BANQUET ROOM RESTAURANT, CAFE & BAR , & OFFICES.( 4 STORY TYPE IIIA,  149 GUESTROOMS FROM 2ND TO FIFTH FLOOR OVER GROUND FLOOR TYPE I-A  RESTAURANT & LOBBY & PARKING).- Non high rise buildingFire variance to be filed at a later time by contractor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11993	17041-20000-10117	1755 N GLENDALE BLVD	90026	13	144A209   285	5423006034	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1955.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.08742	-118.25984	Plan check for energy only. Change of use from existing office/shop to yoga studio. New lighting (incl. emergency). 1,509sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11994	18041-10000-33119	5747 N VAN NUYS BLVD	91401	4	174B149   377	2244028024	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.17527	-118.44907	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11995	17041-10000-34403	10250 W SANTA MONICA BLVD 1510	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR SPACE# 1510 ""JOHN VARVATOS""WESTFIELD CENTURY CITY. SCOPE INCLUDES NEW PANELS, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 2959 SQ. FT."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
11996	14041-20000-14955	1629 N MARLAY DR	90069	4	148-5A175 342	5556031017	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.09984	-118.36837	PV1Microinverter standard plan. Install roof-mounted solar array on SFD. System size: 3.456kW(16) EnPhase M215 microinverters(16) SolarWorld SW255 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
11997	17041-20000-46284	7362 N BOTHWELL ROAD	91335	3	186B117   626	2116003040	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.20459	-118.56079	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. (E) solar system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
11998	15041-20001-32807	8520 W VENICE BLVD	90034	10	123B173   453	5065007021	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Approved	03/29/2017 12:00:00 AM	ADDRESS	34.03435	-118.37888	03/29/2017 Revisions to approved set.  Changes to lighting system throughout.  *****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial, 2-story building. Project scope is a tenant improvement. Total lighting area = 7,115 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
11999	15041-10001-42339	2159 E BAY ST	90021	14	123A217   424	5166001002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	ADDRESS	34.03156	-118.22794	02/25/16Changes to an approved set of plans. All changes made under delta 1. Changes include the voltage class of the main switchboard going from a 120/240V 3 phase, 4w to 240V 3 phase 3w, removing the LED flood lights, relocating receptacles, and replacing the indoor light fixtures. (((((T-24, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING FOR INDOOR AND OUTDOOR SPACES AND NEW RECEPTACLES. TOTAL SQ. FT. 9539.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12000	18041-20000-42884	11785-11795 W GATEWAY BLVD 1-8-ms1	90064	11	120B153   357	4257006022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Apartment			11/08/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.02692	-118.44407	Remodel of (E) 2-story 14-unit apartment complex.  600A service upgrade - (2) buildings with common service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12001	19041-10000-20247	8219 S VERMONT AVE	90044	8	099B197  1441	6033022005	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	33.96391	-118.29204	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL WITH 31 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12002	18041-10000-04269	20050 S VERMONT AVE	90502	15	057B197   154	7351033062	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.84838	-118.29024	PC for T24 only for replacement of outdoor metal halide fixture with new LED fixtures. Total area 122800sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12003	16041-20000-17861	1818 W 7TH ST #525	90057	1	132A203   209	5142006021	C2-2	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Expired	07/30/2018 12:00:00 AM	ADDRESS	34.05512	-118.2742	Plan check for Title 24 only in existing space. Total area: 7,260 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12004	12041-10001-26504	19200 W DEARBORN ST PV1	91324	12	198B121   664	2762017030	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2013 12:00:00 AM			PC Approved	02/25/2013 12:00:00 AM	ADDRESS	34.23719	-118.55072	CHANGES TO APPROVED SET OF PLANS: REMOVED 1 MODULE AND REVISED CALCULATIONS TO MATCH. WIRING REMAINS THE SAME.INSTALL ON THE ROOF OF A SFD A 12KW PHOTOVOLTAIC SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12005	18041-10000-12857	9940 N REMMET AVE	91311	12	201B105   255	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.25126	-118.6003	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12006	17041-20000-00293	22431 W MARLIN PL	91307	12	183B101   392	2024025015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.19695	-118.61568	Plan check for a PV1 ground-mounted PV system. System size is 9 kWac and consists of (1) inverter and (36) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12007	14041-10007-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	NO CHANGES UNDER THIS APPLICATION. THIS IS UPDATE CALCULATIONS TO REFLECT UPDATED TENANT SQUARE FOOTAGE FOR PROJECTED LOADS. PROJECT IS STILL PENDING 30-DAY DEMAND READING TO REFLECT DEMAND LOADS TO COMPLY WITH 220.87 IN FUTURE. DELTA 26 AND 27 NOTED ON PLANS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12008	13041-10000-04541	12630 W BESSEMER ST	91606	2	177B161   819	2332021005	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	05/22/2013 12:00:00 AM	ADDRESS	34.18021	-118.40852	PV1 ROOF MOUNTED PHOTOVOLTAIC SYSTEM INSTALLATION IN SINGLE FAMILY DWELLING. SYSTEM SIZE IS 11.50 KW DC USING TWO TRANSFORMERLESS INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12009	13041-20001-25437	23234 W ARMINTA ST	91304	12	189B093   543	2020022022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM			PC Approved	09/21/2013 12:00:00 AM	ADDRESS	34.21256	-118.63329	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5 KW AC USING 24 MODULES. 3 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12010	18041-20000-29351	1135 N MANSFIELD AVE 4th Floor	90038	4	144B181   376	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.0918	-118.34057	Tenant improvement to (E) 4th floor tenant space of commercial office building.  Plan check for energy - 7,684 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12011	19041-10000-32282	6633 N ODESSA AVE	91406	6	180B137   200	2231006031	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	06/06/2020 12:00:00 AM	ADDRESS	34.19131	-118.49037	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12012	10041-20000-18827	4160 N EAGLE ROCK BLVD	90065	14	156A219   159	5472001031	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.00	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	09/21/2011 12:00:00 AM	ADDRESS	34.12161	-118.22511	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12013	14041-20001-24100	11800 N BABBITT AVE	91344	12	216B133   637	2606017014	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM			PC Approved	09/17/2014 12:00:00 AM	ADDRESS	34.28473	-118.50856	Expedited plan check per applicant request.  PV1.  Install 6.05 kW roof-mounted, utility-interactive PV system.  Center-fed service panel with derating of main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12014	17041-10000-31808	10375 W WASHINGTON BLVD	90232	5	117B165   217	4208006026	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.01891	-118.40251	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 13750 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12015	19041-10000-31322	6357 W ARIZONA CIR	90045	11	105B165   632	4110014022	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	33.98057	-118.39827	PLAN CHECK FOR ENERGY ONLY TO A TENANT IMPROVEMENT  PORTION OF WAREHOUSE TO OFFICE AND REMODEL RESTROOMS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. IS 1084.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12016	16041-20000-42430	12385 N SAN FERNANDO ROAD #41	91342	7	219B149   648	2611007050	(T)(Q)RAS3-1-CPIO, C2-2D-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.29518	-118.45448	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12017	13041-10000-35464	6922 W HOLLYWOOD BLVD	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Expired	01/13/2016 12:00:00 AM	ADDRESS	34.10137	-118.34103	INSTALLING EMERGENCY LIGHTING IN NON-HIGH RISE BUILDING. PLAN CHECK AND PERMIT WILL BE ON THIS APPLICATION. ALL WORK IS INTERIOR PER CONTRACTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12018	11041-10000-06647	529 N BROAD AVE	90744	15	030B205   912	7418006023	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Apartment			04/04/2011 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	33.77664	-118.26103	INSTALL NEW FIRE ALARM SYSTEM IN NEW 2-STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12019	15041-20000-39150	120 E 68TH ST	90003	9	102B205   300	6011004004	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Expired	02/06/2018 12:00:00 AM	ADDRESS	33.97776	-118.27306	PV1, roof mounted solar panel, 7.6 kW AC system   (31)modules: SUNEDISON270,   (1)inverter: SE7600A-US.  ((Submittal per applicant))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12020	11041-20000-15879	127 S SAN VICENTE BLVD Bulletin-80TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Info Complete	07/28/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin #80TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12021	18041-20000-06104	3420 S VIRGINIA ROAD	90016	10	120B185   949	5046004007	RD3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.02485	-118.33933	plan check for battery back up system with an existing solar system - battery size = 14kwh with backup gateway.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12022	19041-20000-48441	9074 N DE GARMO AVE	91352	6	195B173    52	2408033010	M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	06/25/2021 12:00:00 AM		Issued	06/25/2021 12:00:00 AM	ADDRESS	34.234	-118.37344	PLAN CHECK FOR SERVICE UPGRADE, NEW 2000A SERVICE AND (2) 75 KVA TRANSFORMER AND PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12023	19041-10000-11727	285 S LUCAS AVE	90026	13	133-5A207 285	5153028002	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	05/03/2021 12:00:00 AM	ADDRESS	34.05877	-118.26169	NEW FIRE ALARM SYSTEM IN A NEW HOTEL.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12024	14041-10002-06161	541 S SPRING ST	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM			PC Approved	05/19/2016 12:00:00 AM	ADDRESS	34.04657	-118.2507	05/18/16: Change to approved set by modifying the load for the restaurant  panels, voltage drop calculation and EGC update. All changes are under delta-3 only.3/8/16: Supplemental to approved set on Delta-1:New (6) 100A panels and (3) 400A panels for designed load only. All new load shall be under a separated permit. ***NEW 2000A SERVICE FOR EXISTING ADAPTIVE REUSE BUILDING. THIS SERVICE IS FOR RETAIL TENANTS ONLY. PLAN CHECK FOR POWER ONLY. NO LOADS AT THIS TIME. SERVICE ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12025	14041-10000-34871	2303 E 11TH ST	90021	14	120A217    54	5167009029	M3-1-S-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Expired	01/11/2017 12:00:00 AM	ADDRESS	34.02346	-118.23131	T.I.  Install 8 each texile machinary  and 4 transformers and 1 sub panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12026	13041-20000-18865	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	34.24205	-118.59773	T24 FOR EXISTING WAREHOUSE. TOTAL SQRFT 94622 INDOOR AND 5400 OUTDOOR. TOTAL CONNECTED LOAD LESS THAN 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12027	18041-20000-07306	9301 N CORBIN AVE Suite 2001	91324	12	198B117   116	2761040014	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.24034	-118.56251	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,127 sq. ft.Note: Building application has been generated under 18016-10000-01453	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12028	16041-10000-13561	241 E CANNERY ST	90731	15	015B205     7	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.73978	-118.26796	TI TO 2ND FLOOR COMMERCIAL. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12029	19041-20001-00983	7432 N RESEDA BLVD	91335	3	186B125   557	2119017054	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Approved	02/04/2019 12:00:00 AM	ADDRESS	34.20567	-118.53585	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 128.7 kWdc/112.4 kWac and consists of (4) inverters, (390) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12030	16041-20001-43907	4834 S LINCOLN BLVD	90094	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	33.97831	-118.43572	Plan check for energy only. TI to existing veterinarian clinic. New lighting (incl. emergency) and receptacles. 3,600sqft. ===== Original permit pulled  under master application. Supplemental permit under this application to capture fees for 20 extra circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12031	13041-20001-25439	4117 W DON MARIANO DR	90008	8	114B181   563	5026004012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.00656	-118.3429	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6 KW AC USING 24 MODULES. 3 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12032	13041-10001-07822	380 W WORLD WAY T38	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	PIN	33.94461393	-118.39808495	plan check only. changes to approved set of plans: ASBUILT showing POS, undercounter recep, and cook oven items that were on the panel schedule but not on the floor plan. Border Grill.renovation of retail space. new restaurant. 4 new branch circuitsoriginal description:FULL PLAN CHECK FOR POWER AND ENERGY PER INSPECTOR REQUIST. BACK ROOM SUBMITTAL. TOTAL ENERGY 625 SQ FT. ASSIGN TO FRANCIS. LAX AIR PORT CONCESSION. TOM BRADLEY TERMINAL. T38	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12033	13041-20000-13949	2910 S DANALDA DR	90064	5	126B165  1023	4316014015	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	08/01/2013 12:00:00 AM	ADDRESS	34.03811	-118.40209	New rooftop PV System for an existing single family dwelling.  Inverter has an integrated transformer per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12034	11041-10001-10284	275 W CENTER DR PS-2B	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Closed	03/12/2013 12:00:00 AM	PIN	33.94397606	-118.40429148	Revision to previously approved plans; increased area of workshop with additional normal and emergency lighting fixtures, and relocate receptacle outlets. Original; P/check is under PCIS 11041-10000-10284 but Originaol permit was issued under PCIS 11041-10000-10298.(CHANGE OF LIGHTING TO TEMPORARY WORKSHOP IN PARKING PS-2B AT LAX  (NORTH OF 275 BUILDING).  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK ONLY.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12035	10041-20002-08869	4425 S CENTRAL AVE	90011	9	112-5A209 121	5108028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	01/24/2011 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.00306	-118.25677	Supplemental application to approved plans. Relocate new xfrmr and add 2 ckts to the electrical room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12036	18041-10001-31007	2029 W BLAKE AVE	90039	13	148-5A213  73	5442017001	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.10243	-118.24364	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY. ADDING 1 NEW LIGHTING FIXTURE AND REDUSING LIGHTS. <<Plan check for T24 only, Tenant Improvement to existing Restaurant.  Combine two restaurant spaces into one. Total area: 1,252 sq.ft(B# 18016-10000-25196)>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12037	16041-20000-28217	16925 W RAYEN ST	91343	12	195B133   189	2688026037	RA-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.23222	-118.50117	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.5 KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12038	16041-20002-32680	5218 E YORK BLVD	90042	14	156A225   400	5478005007	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM	ADDRESS	34.12041	-118.20203	12.7.2016 - Plan check for modifications to approved set. Update main service panel (still 200A, no longer center fed - no longer need to derate main). Changes clouded.======Property was misidentified as 1/2 family dwelling in initial application.  Plans previously approved under standard plan for 1/2 family dwellings.  Plan check fee charged for check of contractor design build set.  Additional permit fees under inspection to cover fee difference arising from change from SFD PV to commercial PV.  Service load calculations are attached to previously approved standard plan for purposes of verifying derated service main rating.  (((Plan check for installation of roof-mounted solar array on SFD. Interconnect with 200A MSP. Derating main breaker to 150A. (30) EnPhase M250 microinverters. (30) 285W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12039	11041-20000-09159	4362 N EAGLE ROCK BLVD	90041	14	156A219    61	5474024016	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1862.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.12336	-118.22151	PLAN CHECK FOR T24 ENERGY FOR REPLACING EXISTING LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12040	13041-10000-10850	3742 S JASMINE AVE 1-27	90034	10	120B165  1130	4313005020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Apartment			04/26/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.02297	-118.40269	NEW FIRE ALARM CONTROL PANEL AND 1 SMOKE DETECTOR FOR EXISTING HIGH RISE APARTMENT BUILDING. EXISTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12041	10041-20004-01241	8941-8955 N TAMPA AVE	91324	12	195B117    25	2783028013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM			PC Approved	12/10/2010 12:00:00 AM	ADDRESS	34.23285	-118.55413	Plan check only. Delta 2 revision to replace 3500 rate switchboard to 3000A switchboard. No change on load calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12042	15041-20000-21192	6727 N WHITMAN AVE	91406	6	180B141   117	2233001027	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.19275	-118.47627	Installation of new roof mounted solar PV array.  Total system size = 4.3 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12043	16041-10001-28370	811 W WILSHIRE BLVD 2ND FLR	90017	14	130-5A209 205	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM			PC Approved	02/01/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	02/01/2017 Changes to an approved set of plans. Changes include add new lighting fixtures to elevator lobby. Changes apply to delta 2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12044	13041-10000-35936	420 E 11TH ST #112	90015	14	124-5A209  72	5145023038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.0365	-118.25443	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 777 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12045	15041-10000-00143	13455 W MAXELLA AVE SUITE 111	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/05/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	33.9867	-118.44159	Energy plan check for Restaurant T.I. work including new transformer, panel boards and circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12046	19041-20000-03270	1068 N VILLA GROVE DR	90272	11	129B129   374	4409007003	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.04983	-118.51344	PV1.  Install 11.73 kW DC / 10.62 kW AC roof mounted grid tied PV system.  (34) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12047	10041-20000-15221	1446 N DEVLIN DR	90069	4	147B169   855	5560001020	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2010 12:00:00 AM			PC Info Complete	09/17/2010 12:00:00 AM	ADDRESS	34.09575	-118.38711	Plan check for new single family dwelling with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12048	17041-10000-06292	12700 W GRIDLEY ST	91342	7	225B161   199	2580016***	A1-1XL, OS-1XL	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.31626	-118.40913	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  20050 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12049	17041-10000-07142	7301 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	33.94207	-118.423	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM CAFETERIA TO OFFICE (TRAINING ROOMS). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2185 SQ. FT. B#17016-10000-04738	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12050	11041-20000-11873	3501 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	ADDRESS	34.02194	-118.28455	PLAN CHECK T24 ENERGY WIRING ALTERATIONS AND MANDATORY MEASURES FOR USC THH BUILDING CLASSROOM EXPANSIONS. ROOMS #B9, B10, 103, 106, 108, 110, 112	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12051	17041-10000-08627	5430 W PICO BLVD	90019	10	129B177  1006	5069030024	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.04846	-118.35671	PC for energy only, outdoor. Removing HID fixutres and replacing them with New LED ones. Area: 12,550.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12052	17041-20001-44053	23664 W CANDLEWOOD WAY	91307	12	186B093   655	2027013027	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.20246	-118.64328	expeditepv1install roof mounted pv system sized 13.1kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12053	10041-10008-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM			PC Approved	05/06/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	REVISED LOAD ON FEEDER # 10 OF 4CSIPC DIST BD AND FEEDER # 9 CORRECTED TYPO ON AMP RATING OF THE CB(((((((((single line diagrams with existing switchboards and distribution boards supplying tenant panel boards at the North Core  Concessions. Review was requested such that Westfield will have knowledge which feeders supply a tenant space. Additional plans will include design and actual loads for each tenant space to be used by the plan checker to verify a panelboard or distribution board is not overloaded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12054	19041-20000-45250	3524 S CHESAPEAKE AVE	90016	10	120B181  1057	5046015033	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Apartment			11/05/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.02305	-118.34505	New fire alarm system for new construction.  (83) signaling line and notification devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12055	14041-10001-05689	2343 N CABOT ST	90031	13	144B213   222	5445030024	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.09299	-118.23976	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(24) MODULES: CANADIAN SOLAR CS6P-250PX(1) SOLAREDGE SE5000A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12056	13041-10000-13607	3812 S GRAND AVE	90037	9	117A203   164	5122027026	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.01465	-118.27947	FA. REPLACE (E) SPRINKLER MONITORING SYSTEM IN (E) BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12057	18041-10000-47035	4752 W WASHINGTON BLVD	90016	10	126B181  1166	5061017001	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2186.00	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.0396	-118.3432	INSTALLING NEW LIGHTS IN AN EXISTING RETAIL SPACE. NO CHANGES TO FLOOR AREA, USAGE OR OCCUPANCY.  T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-31479.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12058	14041-10000-13041	1016 S TOWNE AVE # 117	90021	14	124-5A211 349	5132009***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.03362	-118.24986	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES, TOTAL AREA 812 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12059	18041-10000-18671	922 E E ST	90744	15	030B209   812	7424017043	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	33.77595	-118.25106	INSTALLING 5 NEW MOTOR CONTROL CENTERS WITH  ABOUT 180 MOTORS AND TWO COMPRESSORS AND TWO BAILERS FOR A NEW CONVERYOR SYSYTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12060	16041-10000-36339	3201 S HOOVER ST SUITE 1860	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	PC  for title 24 Energy only. Scope includes new lighting and receptacles.Total area of 5224 sq.ft (indoors and outdoors)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12061	17041-20000-06243	301 W 6TH ST	90731	15	015B201   132	7455012015	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	33.73862	-118.28366	TI to (E) restaurant space - interior alteration and exterior lighting.  Plan check for energy.  Building permit filed under 16016-10000-06349	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12062	18041-10000-46306	9404 N LEMONA AVE	91343	7	198B149   161	2650034018	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	05/24/2019 12:00:00 AM		Issued	05/24/2019 12:00:00 AM	ADDRESS	34.24125	-118.4587	T24 ONLY FOR NEW PERIMETER LIGHTING FOR SMALL ATHLETIC FIELD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12063	15041-10000-41109	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	Energy plan check for an office T.I located in the 16th floor of a high rise building. Scope includes new light, receptacles; Work area covers for (6) private office and (1) open office with a total area of 1896-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12064	19041-20000-15329	10423 N LIMERICK AVE pv1	91311	12	207B109   678	2707011029	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.25977	-118.58328	pv1install roof mounted pv system sized 6.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12065	11041-10000-09718	448 S HILL ST 506	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Approved	05/12/2011 12:00:00 AM	ADDRESS	34.04896	-118.25139	TI ON THE 5TH FLOOR OF AN EXISTING 13-STORY OFFICE BUILDING.  T-24 WITH EMERGENCY, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12066	14041-20000-29273	10678 W KURT ST	91342	7	213B177    91	2529016010	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM			Reviewed by Supervisor	10/31/2014 12:00:00 AM	ADDRESS	34.2787	-118.36364	PV1 SFD. TOTAL SYSTEM SIZE 6.45KW AC USING MICROINVERTER SYSTEM. USING 2 STRINGS. USING ENPHASE M215. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12067	11041-10000-18914	6333 W 3RD ST # 316	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	REMODELING OF THE SHORTCAKE  BAKERY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12068	14041-20001-12313	627 N MCCADDEN PL	90004	4	141B185   703	5524018014	R1-1-HPOZ	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2014 12:00:00 AM			PC Approved	05/17/2014 12:00:00 AM	ADDRESS	34.08268	-118.33754	Fee for epedite only.***Roof mounted PV sysem with enphase microinver, model M215-60-.  System size 2.55KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12069	10041-30000-00287	1888 S CENTURY PARK EAST Greenleaf	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.06104	-118.41402	TI - existing highrise - lobby / new restaurant (Greenleaf) - Assembly area - Permit is for new ckts, new equipment, new panels.  P/C is for Power and Energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12070	14041-10000-02219	4227 S HOOVER ST	90037	9	114B197   874	5019005005	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Apartment			01/27/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.00664	-118.28736	pc for power only. NEW SERVICE (600A) to replace damaged service. REPLACE APT PANELS BUT (E) CIRCUITS. 2 typical unit panels and house panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12071	17041-10000-00976	2223 S FEDERAL AVE	90064	11	123B149   358	4260014009	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Info Complete	01/11/2017 12:00:00 AM	ADDRESS	34.03474	-118.44559	Plan check for Title 24 only in existing space T.I. future tenants. Total area: 4,900 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12072	16041-10005-12885	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Closed	10/15/2020 12:00:00 AM	ADDRESS	34.21922	-118.44896	"Supplemental application for changes to layout of single line to existing 13 story commercial highrise adaptive resuse project.  upzise emergency generator to 500KVA,  Relocate loads on ""MS1A"" & ""MS2"",  add new loads and electrical equipment with revisions to lighting and power, revised load calculations, VD% and fault current updates on plan.  All revisions have been noted under delta 2 changes"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12073	10041-10000-18415	948 S CROCKER ST # 5 & # 6	90021	9	124-5A211 204	5132002029	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.03501	-118.25004	EXISTING WAREHOUSE TENANT SPACE CONVERTED TO RETAIL SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12074	13041-10001-03076	1643 N LINDACREST DR	90210	4	147B165   129	4352006021	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.10086	-118.40508	Plan check for revision to approved plan. Change module type from Trina solar module to Yinglisolar YGE-245 only. No change to AC side of PV System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12075	19041-20001-13478	20200 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM			PC Approved	05/31/2019 12:00:00 AM	ADDRESS	34.27515	-118.57076	05-31-2019 Changes to an approved set of plan, changes include conductor size and conductor route. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12076	18041-10000-34691	1020 S FIGUEROA ST	90015	14	127-5A207  71	5138012023	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04442	-118.26422	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12077	14041-20000-36011	1577 E 51ST ST	90011	9	111A213   253	5106023038	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	33.99674	-118.24515	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.2KW INTERCONNECTED WITH MSP.(24) HYUNDAI HEAVY INDUSTRIES HIS-M250 MODULES(24) ENPHASE M215 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12078	14041-20000-20388	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake			2088.01	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	34.06281	-118.2731	Titlte 24 plan check only on a 200SQ feet server room. per customer, the area  is a test  lab for equipment only, no patient, patient care nor test subjecs etc..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12079	19041-10000-36429	400 S HOPE ST 13TH FLR-STE 1320	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Issued	11/20/2019 12:00:00 AM	ADDRESS	34.05199	-118.25366	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TENANT IMPROVEMENT  (E) OFFICE. TOTAL SQ. FT. 3899.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12080	18041-10000-07123	1717 N VINE ST	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.10222	-118.32701	PLAN CHECK FOR KITCHEN TI IN A HOTEL. TOTAL CONNECTED LOAD >400A. WORK DONE ON THE 5TH AND 6TH FLOOR WITH POOL CIRCUITS ON THE 1ST AND 2ND FLOORS. SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT, RECEPTACLES AND LIGHTS. TOTAL AFFECTED 3189 SQ.FT INDOOR. B# 17016-10000-08652	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12081	14041-10001-17736	124 S CROFT AVE	90048	5	138B173   687	5511014007	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			10/07/2019 12:00:00 AM			PC Approved	11/05/2019 12:00:00 AM	ADDRESS	34.07387	-118.37406	Plan check only. Delta B changes to approved set. CHANGES APPLIED TO THE ELEVATOR HORSE POWER, SERVICE LOAD CALCULATION AND UNITS LIGHTING AND POWER LAYOUT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12082	14041-20001-06221	10910 W WALNUT DR	91040	7	201B173   145	2542011015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM			PC Approved	04/09/2014 12:00:00 AM	ADDRESS	34.25029	-118.36814	((Expedite fee))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12083	18041-10000-31155	10866 W WILSHIRE BLVD 225	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.05907	-118.442	PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT NON STRUCTURAL INTERIOR PARTITIONS - TOTAL ASFFECTED AREA = 1551 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12084	10041-20000-20549	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM	10/15/2010 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.27455	-118.56289	parking structure energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12085	13041-10001-30833	21250 W MULHOLLAND DR	91364	3	162B105    79	2173018005	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/29/2014 12:00:00 AM	ADDRESS	34.14313	-118.59627	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. STANDARD PLAN. 2 STORY. SYSTEM SIZE: 11 KW.(44) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS IG PLUS V 10.0	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12086	17041-10000-02940	6944 S KNOWLTON PL	90045	11	102B173   375	4103013103	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			01/30/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	11/15/2020 12:00:00 AM	ADDRESS	33.97371	-118.37115	PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. SCOPE INCLUDES 128 FA DEVICES, AND 5 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12087	18041-10000-03234	14626-14640 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.22128	-118.45073	PC FOR T-24 FOR A NEW PARKING WITH NEW LIGHTS. TOTAL AFFECTED AREA IS 68653 SQ. FT. B#17020-10000-03510	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12088	19041-20000-05938	5918 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Hermon		1837.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	PIN	34.10513905	-118.18392142	TI to (E) commercial tenant space - pharmacy.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12089	17041-20000-20987	16326 W BARNESTON ST	91344	12	216B137   499	2605014015	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.28532	-118.48713	Plan check for a PV1 roof-mounted PV system. System size is 4.3 kWac and consists of (17) modules, (17) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12090	17041-10000-11324	5921 S WESTERN AVE	90047	8	105B193    92	6001014001	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.98767	-118.3091	PC for energy only, outdoor T-24. Removing HID fixtures and replacing them with new LED ones. Area: 39,900. Total of 14 light fixtures	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12091	17041-20002-31073	5738 N OAKDALE AVE	91367	3	174B113   152	2153018019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.17554	-118.56553	Revisions to approved set.  Change of inverter power ratings, change of # of modules from (46) to (38), and omission of subpanel. (((PV1.  Install roof mounted PV system sized 12 kW interconnected with MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12092	16041-20000-17509	8500 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Expired	06/20/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	Plan check for Fire Alarm system. New Fire Alarm Panel, total fire alarm devices: 7	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12093	16041-10000-07258	12121 W BLUFF CREEK DR GRD FLOOR	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	33.97874	-118.40463	T-24, PC FOR ENERGY ONLY. TI FOR A FIRST FLOOR OFFICE SPACE; INCLUDES MINIMAL DEMO, NEW OFFICE AND CONFERENCE PARTITIONS. SCOPE INCLUDES NEW LIGHTS AND RECEPACLES TO OFFICE SPACE. TOTAL AFFECTED AREA IS 7288 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12094	17041-10001-37323	12907 W SUNSET BLVD	90049	11	132B137   407	4406009015	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.05724	-118.49153	[[[4/4/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES. ADDITION OF A DISCONNECT TO THE ENERGY STORAGE DEVICE]]PLAN CHECK FOR A BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF AN (E) PV SYSTEM AND (N)TESLA POWER WALL 2-BATTERY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12095	13041-10000-20563	3333 W 3RD ST	90004	13	135B197    39	5501013800	R4-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	PIN	34.06976947	-118.28904522	lighting provisons for building alteration for SoCal Gas Company office building.  Newly connected load below 400 A, title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12096	18041-20000-24188	4701 S BROADWAY	90037	9	112-5A203 353	5110010034	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.00087	-118.2786	Plan check for Title 24 only. Project site is two tenant spaces in an existing commercial building. Project scope is a fire repair. Total lighting area = 20,500 sq. ft. Tenant spaces are 4707 and 4709B.Note: Building application has been generated under 17016-20000-29451	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12097	17041-10000-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	PC for power and energy for core and shell ancillary building in LA football club. PC for new distribution boards, new equipment, transformers and panelboards. Total area is 56258 sqft. Building #16041-10000-05104	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12098	14041-10000-19790	13361 N GLENOAKS BLVD BLDG A	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.3146	-118.45921	PLANCHECK FOR POWER AND ENERGY FOR A MIDDLE SCHOOL. under 2013 energy code.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12099	16041-10001-41298	600 W 7TH ST # 120	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Approved	03/31/2017 12:00:00 AM	ADDRESS	34.04728	-118.25685	Plan check for Title 24 only in existing space T.I. in  for restaurant. Total area: 980 sq ft. plan check only. Permit nmber refet to 16041-10000-41298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12100	10041-20000-02511	12039 W BRANFORD ST BLDG #1	91331	7	204B165   189	2537017017	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM			PC Approved	02/12/2010 12:00:00 AM	PIN	34.25485468	-118.39602222	Changes to 08041-20000-05777WAREHOUSE BLDG #1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12101	15041-20000-06195	18600 W CHATSWORTH ST	91326	12	207B121   416	2728021003	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.26426	-118.53957	Installation of new roof mounted solar PV array.  SIngle inverter system.  Total size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12102	18041-20002-12297	1852 N MARCHEETA PL	90069	4	150B169  1092	5561008033	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.10612	-118.38882	Revisions to approved set. Relocation of modules on the rooftop and minor SLD revisions.  (((Plan check for PV roof mounted system. System size: 27kWac with 75 AC Modules connected to load center with existing 400A service.Permit fees $63.64 due to Senate Bill 1222)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12103	17041-10000-12275	5513 W 82ND ST	90045	11	099B173   718	4127022022	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Expired	03/05/2024 12:00:00 AM	ADDRESS	33.9641	-118.37577	Plan check for PV roof mounted system. System size: 3.8kW with 10 modules,10 optimizers and 1 inverter(3.8kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12104	17041-10001-11050	813 S FLOWER ST	90017	14	129A207   189	5144021031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.04705	-118.26051	Change to approved set by changing all copper feeder to aluminum. lighting floor being updated with new lighting plan and calculation. All changes under clouded area only. hour is pending (((FULL PLAN CHECK FOR POWER AND ENERGY FOR (E) 12 STORY HOTEL.SCOPE OF WORK INCLUDES NEW 1200A SERVICE, AND ALL NEW DISTRIBUTION BOARD WITH ASSOCIATED EQIPMENT, INCLUDING BUT NOT LIMITED TO TRANSFORMERS, HVAC, POWER AND LIGHTING. TOTAL SQ. FT. = 22567(INDOOR = 18767, OUTDOOR = 3800:ESTIMATED))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12105	13041-10000-21305	1431 S BURNSIDE AVE	90019	10	129B177  1179	5069032011	RD2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.04756	-118.3552	PV1.  Install 4.32 kW kW roof-mounted solar array, interconnect with main service panel.  {Microinverters: Enphase M215-60-2LL-52x} {20 modules: LG260}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12106	17041-10002-36016	314 W 58TH ST	90037	9	108B201  1293	5101040005	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	33.98964	-118.27898	EXPEDITE PER APPLICANT REQUEST.((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 92KWac. (259)MODULES-Q.CELLS Q.PEAK-G4.1 300(4)INVERTERS-YASKAWA SOLECTRIA PVI 23TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12107	12041-10000-08683	368 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Expired	12/02/2014 12:00:00 AM	ADDRESS	33.93087	-118.26711	PLAN CHECK NEW 20.5KW ROOF MOUNTED AND GROUND MOUNTED PHOTOVOLTAIC SYSTEM FOR APARTMENT BUILDING. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12108	13041-10000-22930	2015 W WILSHIRE BLVD	90057	1	132A203    15	5141001026	C4-2	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.05774	-118.27509	[[[[TITLE 24 PLAN CHECK ONLY.  AREA DOES NOT REQUIRE UNIT EQUIPMENT,MZ 08/22/13]]]]]INSTALL NEW FLOURESCENT FIXTURES. INSTALL (3) NEW RECEPTACLES & (3) NEW SWITCHES. 3 OF 3 W/ #13042-10000-13159.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12109	17041-10000-21574	3701 W WILSHIRE BLVD #101	90010	10	135B193  1020	5503029024	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Info Complete	06/29/2017 12:00:00 AM	ADDRESS	34.06188	-118.30708	PC FOR OFFICE TI. CHANGE OF USE FROM RESTAURANT TO OFFICE SPACE OF SUITE 101 (W/ MEZZANINE)  IN A HIGH RISE. TITLE-24  ENERGY ONLY.  TOTAL AFFECTED AREA  5,380 SQ.SFSCOPE OF WORK  INCLUDES NEW PANELS, LIGHTS, RECEPTACLES AND EQUIPMENT. BL #17016-10000-15513	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12110	19041-10000-10264	5601 N LAUREL CANYON BLVD	91607	2	174B165   704	2340026075	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.17234	-118.3967	Remove HID fixture and replace with new LED fixture, T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12111	19041-10000-14131	1028 W VIA LA PAZ	90732	15	021B197    31	7445015050	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Issued	05/29/2019 12:00:00 AM	ADDRESS	33.75671	-118.30019	[e-plan] PLAN CHECK FOR INSTALLATION OF TESLA POWER WALL TO EXISTING PV SYSTEM USING 200A LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12112	12041-10001-02128	11528 W DUQUE DR PV1	91604	2	156B169    72	2381023015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2012 12:00:00 AM			PC Approved	05/07/2012 12:00:00 AM	ADDRESS	34.12768	-118.38553	Plan check for 6.27KW roof mounted photovoltaic system. Existing permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12113	13041-10000-24696	1046 S SELBY AVE	90024	5	135B153   639	4360009015	R1-1	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Expired	10/05/2015 12:00:00 AM	ADDRESS	34.06212	-118.43789	PV1 ROOF-MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECCT WITH MAIN PANEL IN A 2-STORY HOUSE. SYSTEM SIZE IS 7.5 KW DC. TRINA-250PC05 MODULE, FRONIUS V 7.5 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12114	16041-10000-03870	7400 W 81ST ST	90045	11	096B157    61	4114015018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	33.96287	-118.42675	PV1, INSTALL 4.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGEL FAMILY HOUSE. (15) MODULES: LG 310N1C-G4(15) MICROINVERTER: ENPHASE 250W M250-2LL-60-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12115	19041-20000-15113	23316 W BLYTHE ST	91304	12	189B093   376	2020024030	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.21399	-118.63574	PC FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 7.98KW DC/7.6KW AC/7.246KW AC CEC. SCOPE OF WORK INCLUDES (28) Q CELL PV MODULES WITH SE P320 POWER OPTIMIZERS, AND A SE7600 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12116	18041-10000-00884	16600 W SHERMAN WAY #220 & 230	91406	6	183B137    71	2225005010	(Q)CR-1VL, (Q)P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Info Complete	01/09/2018 12:00:00 AM	ADDRESS	34.20096	-118.495	"PC FOR OFFICE TI FOR SUITES 220 AND 230 FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA 6124 SQ.FTB# 18016-20000-00600""COMPLY WITH DEPARTMENT ORDER effective date 12/15/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12117	16041-20000-17784	7900 N BALBOA BLVD Building F	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	Plan check for power and energy. Project site is a new aircraft hangar. Plan check per Article 513, Aircraft Hangars. Work includes a new 400-amp service, (8) panel boards, and associated load. Total lighting area = 29,360 sq. ft.Note: Building permit has been pulled under 15010-30000-03329	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12118	18041-20000-00730	747 S WAREHOUSE ST	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.03468	-118.23965	Plan check for emergency egress lighting on the ground floor of an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12119	14041-10001-09760	3065 S MOUNTAIN VIEW AVE	90066	11	117B153   358	4248007005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/19/2014 12:00:00 AM	ADDRESS	34.01866	-118.44263	Expedited RSES plan chek per applicant request.{{PV1, Install 3.75 kw DC roof-mounted solar array on a two-story home, interconnect with main service panel.(1) Transformerless Inverter: SOLAREDGE SE3800A-US-ZB-U(15) CANADIAN SOLAR CS6P-250X}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12120	19041-20002-06809	9400 S LA TIJERA BLVD PV1	90045	11	096B161   831	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	33.95618	-118.4163	System redesign.  Reduction in number of modules, type and quantity of inverters, elimination of transformers from system design.  New system size is 108.41 kW DC / 97.54 kW AC CEC with (297) modules, (2) 43.2 kW inverters, and (1) 9 kW inverter.  System 1 of 3.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12121	14041-10000-21260	539 N FULLER AVE	90036	5	141B181   980	5526023005	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.08136	-118.34994	1 inverter 6000 Watts. System size 7.905kW. 31 Modules, 3 source ciruits.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12122	14041-10001-23863	5950 W FOREST LAWN DR	90068	4	165B189    11	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM			Corrections Issued	09/04/2014 12:00:00 AM	ADDRESS	34.1522	-118.31832	Title 24 plan check only.  Total area = 1,360 sq. ft.Building application submitted before title 24 part 6 effective date.  Application #: 14016-100000-11771Master permit work description: RENOVATING OFFICE AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12123	12041-20000-02419	2049 S CENTURY PARK EAST # 400	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.05903	-118.41293	ENERGYB PLAN CHECK # 400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12124	17041-10000-45102	307 E JEFFERSON BLVD	90011	9	118-5A205 278	5120016034	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.01722	-118.2691	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12125	16041-20000-35275	13512 W MINEOLA ST	91331	6	195B157    16	2625035009	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.23526	-118.42652	pv1install roof mounted pv system sized 9.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12126	17041-10002-02436	5200 N LANKERSHIM BLVD	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC FOR CHANGES TO APPROVED SET TO REFLECT CHANGES MADE ON THE FIELD. CHANGES INCLUDE CHANGE TO LUMINAIRE TYPE AND 1 NEW CIRCUIT. REVISION TO  FLOOR PLAN AND T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12127	14041-20000-34819	4834 N LA RODA AVE	90041	14	160-5A225 320	5689007034	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.13438	-118.20611	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 4 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (16) SOLARWORLD PLUS SW-275 MODULES(16) ENPHASE M250-60-2LL-S22 MICRO INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12128	16041-10001-00713	1307 N LAGOON AVE	90744	15	033B205   176	7420003025	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	33.78912	-118.26786	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.68KWdc/4.2KWac. (18)MODULES-LIFELINE ENERGY LLE-6M260(1)INVERTER-ABB PVI-4.2-OUTD-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12129	17041-10000-04685	2134 W SUNSET BLVD SUITE F	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.07723	-118.26485	"INTERIOR TI FOR A RESTAURANT ""CHIPOTLE"",  NEW KICTHEN, RESTROOMS, METER SIZE 400A.B# 17016-10000-03228"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12130	18041-10000-45293	11643 W SHELDON ST	91352	6	201B169   105	2537023014	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Reviewed by Supervisor	12/20/2018 12:00:00 AM	ADDRESS	34.24519	-118.386	NEW ROOFTOP MOUNTED 6.37 KW PV SYSTEM ON (E) COMMERCIAL BUILDING (21)MODULES ON ONE PORTION OF THE BUILDING AND (17) ON ANOTHER . THIS ONE INCLUDE THE (21) MODULES ACSYMO 10.0-3 INVERTER .REFERENCE 18041-10000-45303	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12131	19041-20000-32068	7857 N BURNET AVE	91405	6	189B145   476	2209032025	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.2136	-118.46305	TI to (E) commercial warehouse building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12132	13041-10000-32750	1500 W PACIFIC COAST HWY BLDG D	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING DTHIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12133	19041-10000-07719	17163 W SUNBURST ST	91325	12	195B133    32	2690001009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.2346	-118.50777	[ePlan] Roof mounted PV (8.845kW DC) / 7.6 kW AC on SFR, with 1 Tesla Powerwall (13.5 kWH ESS), 1 new 125A load center, 1 inverter, and downsize of main breaker in MSP to 150A . <<Main breaker downsize shall be under separate express permit>	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12134	19041-20000-38356	660 S STANFORD AVE	90021	14	126A213   380	5147029048	[T][Q]C2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			09/25/2019 12:00:00 AM	03/27/2020 12:00:00 AM		Permit Finaled	02/03/2023 12:00:00 AM	ADDRESS	34.0392	-118.24401	2000A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12135	19041-10000-20980	19607 W PRAIRIE ST	91324	12	198B117   138	2761036032	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Issued	06/04/2019 12:00:00 AM	ADDRESS	34.23922	-118.56048	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12136	16041-20000-13976	11604 N BABBITT AVE	91344	12	213B133   426	2607017040	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.28133	-118.50803	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (30) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12137	19041-20000-51716	6120 W ELEANOR AVE	90038	13	144B189   781	5534024006	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			12/16/2019 12:00:00 AM	01/06/2020 12:00:00 AM		Issued	01/06/2020 12:00:00 AM	ADDRESS	34.08972	-118.32522	New corridor lighting in (E) apartment building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12138	18041-10001-30404	13125 N MESA VERDE WAY	91342	7	225B165    19	2580018***	RD6-1XL	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	01/12/2019 12:00:00 AM	ADDRESS	34.31134	-118.40684	"Change to approved set by adding an additional inverter to an online plan. All changes under delta ""A"" only.Portion of the permit fee is paid under 18041-90000-30404.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12139	11041-10000-03396	2151 N SOTO ST	90031	1	136-5A227   5	5211021003	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	06/16/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.06804	-118.19594	254 KW PV SYSTEM OVER AN EXISTING PARKING LOT FOR LAUSD. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12140	10041-30000-10126	3742 S FIGUEROA ST	90007	9	118-5A201 124	5037029002	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.01717	-118.28255	LIGHTING AND POWER AND POWER FOR RESTAURANT. THIS P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12141	18041-20000-29902	15914 W VINTAGE ST	91343	12	204B141  1068	2669016017	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.25184	-118.47903	pv1install roof mounted pv system sized 10.2KW AC interconnected with msp.(32) panasonic 330W modules(32) enphase energy IQ7X microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12142	17041-20000-29588	755 N SEWARD ST	90038	4	141B185   297	5533037001	CM-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.08506	-118.33325	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 6,314 sq. ft.Note: Building permit has been issued under 17016-10000-05469	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12143	19041-10000-16374	4837-4839 N LAUREL CANYON BLVD	91607	2	168B165   317	2356007011	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	05/11/2021 12:00:00 AM	ADDRESS	34.15887	-118.39668	Full plan check power and energy.  area 1,646SF. scope of work 7 new panel for new apartment on an existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12144	13041-10000-19809	4707 N AMIGO AVE	91356	3	168B121   166	2176015002	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM			Reviewed by Supervisor	08/23/2013 12:00:00 AM	ADDRESS	34.1581	-118.5384	INSTALLING ROOF MOUNTED SOLAR ARRAY, INERCONNECT WITH MAIN PANEL. SYSTEM SIZE :16.17 KW. 2 STORY. NEGATIVELEY GROUNDED. 2 INVERTERS: 2 FRONIUS # IG PLUS V 6.0 (6000W), 66 MODULES: TRINA SOLAR # TSM-245 (245 W)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12145	19041-20000-07122	13131 W SHERMAN WAY 300	91605	2	183B157    37	2327003053	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.20136	-118.41904	3000A 480Y/277V 3ph-4w service for new shell warehouse building.  Building permit under 17010-20000-02212.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12146	17041-20001-10064	9171 N DE SOTO AVE BLDG A	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.23778	-118.5888	07/25/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes were made to the lighting and power floor plans. The engineer of record has changed.*****Previous Work Description*****(N) 1 STORY RETAIL BLDG SHELL ONLY.  Plan check for power and energy.  Building A.  Building B permit is being submitted concurrently on same set of plans.  Building permit filed under 17010-20000-00221.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12147	15041-10000-40284	568 N TIGERTAIL ROAD	90049	11	138B141   541	4494001008	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.07065	-118.47902	NEW 2 STORY RESIDENTIAL HOME WITH ATTACHED GARAGE AND A 600AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12148	16041-10000-10202	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Closed	09/19/2018 12:00:00 AM	ADDRESS	33.94502	-118.40714	RENOVATION OF EXISTING I.T. ROOM IN TERMINAL 3 IN LEVEL2.   NO CHANGE IN OCCUPANCY.RECONFIGURE LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12149	19041-20000-17304	444 S FLOWER ST 44th floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	T24 ONLY PLAN CHECK. LIGHTS AND OUTLETS FOR EXISTING HIGH RISE COMMERCIAL BUILDING TWO DIFFERENT RESTROOMS ON THE 44TH FLOOR. TOTAL SQUARE FOOTAGE = 568 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12150	13041-20000-28171	10250 W SANTA MONICA BLVD SUITE 1210	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	pc for t24 energy only. total area 1030 sq ft. retail. cosmetic store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12151	13041-10001-20195	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	TENANT IMPROVEMNTS TO TERMINAL 3 TO ACCOMMODATE THE RELOCATION OF US AIRWAYS INTO TERMINAL 3 SPACES. TITLE 24 PLAN CHECK ONLY.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. LOCATION D & F.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12152	18041-20001-26131	235 S HARVARD BLVD	90004	10	135B193    53	5517014019	R3-1	Central	Wilshire	Wilshire Center-Koreatown		2114.20	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.0701	-118.30428	Plan check for a PV2 roof-mounted PV system. System size is 44.20 kWdc/38.86 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (130) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12153	18041-20000-28421	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.20696	-118.3417	Plan check for Title 24 Energy only in existing space. T.I class room. Total area: 1038 sq ft. B#18016-20000-24124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12154	16041-20001-09545	5830 N RESEDA BLVD	91356	3	174B125    23	2157005001	R3-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.17723	-118.53581	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size 15 kWac and consists of (2) inverters, (55) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12155	13041-10001-27121	17352 W NAPA ST	91325	12	192B133    39	2787025033	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.22642	-118.51159	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. STANDARD PLAN.  SYSTEM SIZE: 8.82 kW.(36) YINGLI # YL245P-29B(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12156	18041-20000-17129	18050 W CHATSWORTH ST	91344	12	207B125   637	2731008023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.26455	-118.52561	service upgrade to an existing commercial building 600 amps, service board only.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12157	14041-20002-04104	1260 N VINE ST	90038	13	144B189   143	5534001400	C2-1-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.09406	-118.32645	SUPPLEMENTAL PERMIT FOR TWO EXTERIOR LED FIXTURES AND FOUR INCANDESCENT INTERIOR DOWN LIGHTS.  ALL FIXTURES ARE LA CITY APPROVED. This is a one story bldg, title 24. fast food.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12158	10041-20000-14773	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM			PC Info Complete	08/25/2010 12:00:00 AM	ADDRESS	34.10137	-118.34182	Restaurant TI. Energy only. This parcel is eligible for issuance of a 30 day time limit permit .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12159	18041-10000-27602	5330 W 102ND ST	90045	11	090B173   205	4129032007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.9435	-118.37353	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12160	18041-30000-39935	6200 W HOLLYWOOD BLVD SUITE 144	90028	13	148-5A189 354	5546028037	[T][Q]C4-2D, [T][Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.10136	-118.32459	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT TO AN EXISTING CORE AND SHELL RETAIL TENANT SPACE. SPECTRUM STORE.BUILDING PERMIT # 18016-40000-31762	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12161	16041-10000-11591	1415 W 49TH ST	90062	8	111B193   840	5016021007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	33.99926	-118.30086	PV1 installation of a roof mounted solar system to a single family home. 12 Microinerters, total size system: 3.0 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12162	10041-10000-14938	1411 N DETROIT ST	90046	4	147B181   853	5548018042	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.0966	-118.34544	INSTALLATION OF A 14.26KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12163	16041-20000-29790	1751 S MALCOLM AVE	90024	5	129B153   378	4325023017	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			08/22/2016 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	06/03/2021 12:00:00 AM	ADDRESS	34.05084	-118.43544	New apartment building 1200 amp service for (2) buildings connected by common roof.  plan check for power and energy.Building application numbers under 16010-20000-02308/09	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12164	18041-20000-49183	11840 W FOOTHILL BLVD UNIT E	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Pacoima		1041.08	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.27347	-118.39434	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12165	17041-20002-23799	9137 N COLLETT AVE	91343	12	198B141   626	2671023005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.23692	-118.48412	expeditepv1install roof mounted pv system sized 5.1kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12166	13041-10000-26308	13190 N BROMONT AVE	91342	7	225B153   419	2509003031	R3-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Public Safety Only			09/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.31012	-118.43675	new fire warning system for 3-stories apt building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12167	14041-20000-18754	5757 W WILSHIRE BLVD 4TH FLR	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.06259	-118.35341	Tittle 24 plan check only on a commercial building for replacing exsiting fluorescent with LED lighting in same location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12168	16041-20000-17362	705 W 34TH ST	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	PIN	34.02214675	-118.28186522	SITE LIGHITNG (USC CAMPUS). PLAN CHECK FOR ENERGY ONLY AND EGRESSS. TOTAL SQUARE FOOTAGE 45268	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12169	11041-10000-21278	10800 W PICO BLVD	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Approved	11/03/2011 12:00:00 AM	ADDRESS	34.04054	-118.4272	"T.I. to an existing retail space in a strip mall, ""Spencers"" Space #309.  PLAN CHECK ONLY for Energy with Emergency lighting."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12170	11041-10001-07237	200 W MANCHESTER AVE	90293	11	096B149   749	4116028014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.00	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	PIN	33.95492043	-118.44692298	NEW ADDITION TO AN EXISTING BUILDING.  ADDITIONAL SQFT IS 5,523 SQFT.  NEW PANEL AND ADDITIONAL BRANCH CIRCUITS.  FULL PLAN CHECK. customer has been here more than 4 to5 times , adiitional hours to cover time needed. this application shows the permit  under inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12171	12041-10000-09968	8900 N DE SOTO AVE #112	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	New manufacturing building for jet parts.   New 4160V, 3-phase, 2000A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12172	17041-10000-37222	10250 W SANTA MONICA BLVD # 2815	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space ""Halo top""  suite 2815"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12173	19041-10001-16901	9035 N INDEPENDENCE AVE	91311										Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	06/10/2019 12:00:00 AM				VOIDED PER APPILCANT REQUEST*************************Expedite per applicant request(((Plan check for a 99.9kw AC / KW 115kw DC PV2 roofmounted system with (1) inverter, (297) modules, (149) optimizer interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12174	16041-10000-12005	19844 W SUPERIOR ST	91311	12	201B113   700	2761021015	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.24594	-118.56602	PV1 roof mounted solar system installation to a single family home. Central inverter: 7.6 kw, 13 solar modules plus optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12175	16041-20000-05818	7625 N MAYNARD AVE	91304	12	186B097   136	2013008052	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.20914	-118.62294	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (13) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12176	14041-10001-15410	5101 N WOODLEY AVE	91436	5	171B141   395	2260020013	RA-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.16222	-118.48386	Expedited RSES plan check per pplicant request.{{PV1, Install 10.45 KW DC roof-mounted solar array on a 1-story house, interconnect with main service panel. Transformerless inverter. With optimizer.}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12177	16041-10000-07445	8000 W SUNSET BLVD C-110	90046	4	147B177  1104	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			Corrections Issued	03/02/2016 12:00:00 AM	ADDRESS	34.09783	-118.36466	T-24, CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE, NO CRITICAL CARE AREAS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACELS. TOTAL SQ. FT. 1400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12178	19041-10000-51299	1014 E MANCHESTER AVE	90001	9	097-5A209 264	6042023030	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	01/26/2021 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	33.96	-118.25717	T-24 ENERGY ONLY PLAN CHECK FOR A TI TO EXISTING RETAIL STORE. SCOPE INCLUDES NEW EQUIPMEN, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 6768 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12179	19041-10000-30681	3462 S WILSHIRE PL	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center-Koreatown		2123.04	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	PIN	34.06070415	-118.29984264	P.C FOR TITLE 24 ONLY INTERIOR TI TO EXISTING RESTAURANT LOCATED IN A HIGH RISE BUILDING. TOTAL AFFECTED AREA 1,610.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12180	17041-10000-16644	2220 W SLAUSON AVE	90043	8	108B189  1378	4005026034	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	33.98895	-118.31841	PC FOR LIGHTING REPLACEMENT, HID TO LED TYPE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12181	17041-10002-11050	813 S FLOWER ST	90017	14	129A207   189	5144021031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM			PC Info Complete	06/27/2019 12:00:00 AM	ADDRESS	34.04705	-118.26051	DELTA 5A CHANGES ONLY. CHANGES TO THE SIGLE LINE EQUIPMENT, FEEDERS AND CONDUCTORS TO MATCH INSTALLED CONSDITIONS PER INSPECTOR REQUEST. LOADS ON THE PANEL ARE UPDATED ACCORDINGLY.ALL CHANGES ARE CLOUDED AND MARKED BY DELTA 5A. Original scope: FULL PLAN CHECK FOR POWER AND ENERGY FOR (E) 12 STORY HOTEL.SCOPE OF WORK INCLUDES NEW 1200A SERVICE, AND ALL NEW DISTRIBUTION BOARD WITH ASSOCIATED EQIPMENT, INCLUDING BUT NOT LIMITED TO TRANSFORMERS, HVAC, POWER AND LIGHTING. TOTAL SQ. FT. = 22567(INDOOR = 18767, OUTDOOR = 3800:ESTIMATED)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12182	14041-10002-25056	1133 S HOPE ST	90015	14	127-5A207 285	5138014006	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	02/15/2018 12:00:00 AM	ADDRESS	34.0416	-118.26394	DELTA 3, 5, 7  CHANGES TO PERMITTED SET OF PLANS ( SHEETS E103-RELOCATE  DIST BOARDS ; SHEET 104-REVISED XFMR DIST; SHEET 201- DELTA CHANGES ; SHEET E202- UPDATED LOAD CALCULATIONS. ALL CHANGES ARE CLOUDED AND IDENTIFIED(((((PLANCHECK FOR POWER AND ENERGY. NEW HIGHRISE MIXED USE BUILDING.building permit #13010-10000-02854  New 28 story residential tower, 22 levels of residential, 1 level of amenity space, and 5 level of parking above grade and 2 level below grade with ground level commercial space.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12183	14041-20000-08158	202 S MAIN ST	90291	11	111B141   444	4286003001	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	33.99763	-118.47899	T.I to existing building.  Install new light.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12184	19041-10000-46365	4234 S GRAND VIEW BLVD	90066	11	111B157  1114	4232015020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			11/11/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	33.99681	-118.42486	[EPLAN] PLAN CHECK FOR 1 TELSA POWERWALL, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL AND PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12185	19041-10000-08518	11839 W SHERMAN WAY	91605	2	183B169    97	2317019902	PF-1XL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.20136	-118.3914	Full plan check for a new 600 Amp service supplying multiple sate approved modulear buildings with a total outdoor lighting area of 9575 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12186	10041-10000-07920	6244 W WILSHIRE BLVD	90048	5	135B177   504	5088015025	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM			Corrections Issued	05/08/2010 12:00:00 AM	ADDRESS	34.06309	-118.36486	FIST TIMME TENANT. NEW DENTAL OFFICE , LIGHTING , POWER AND TITLE 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12187	10041-10000-14406	2416 E 24TH ST	90058	14	117A217    41	5168020006	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Expired	12/09/2015 12:00:00 AM	ADDRESS	34.01614	-118.22959	NEW 600 AMP SERVICE. PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12188	10041-10000-15189	609 S LINCOLN BLVD #B	90291	11	111B145   817	4240016053	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	09/08/2010 12:00:00 AM	ADDRESS	33.99989	-118.46525	TI in an existing retail store (Unit #B). Plan Check is for Title 24 energy calcs and emergency lights. Permit is for  new circuits & AC unit (existing service).  An express  permit was issued for one panel and six circuits under App# 10041-90000-14968.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12189	14041-20000-34148	19781 W RINALDI ST	91326	12	210B117   379	2701040040	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.27517	-118.56478	Renovation to (E) supermarket.  New 600A distribution section for new equipment.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12190	14041-10001-31506	200 WORLD WAY Space-281	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	REVISION TO AN APPROVED SET. CHANGES FROM TRAC LIGHITNG TO LOW VOLTAGE TRACK LIGHTING. NOTE CHANGES ON DELTA 8. PC FOR ENERGY ONLY. WATTAGE OF TRACK LIGHITNG PER FULL RATING OF TRANSFOMER. (((Full plan check for first time tenant, Starbucks Coffe Company, at Terminal-2 level-1 space281. per F.Y)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12191	17041-10000-25907	10221 S COMPTON AVE	90002	15	091-5A213 211	6048012027	PF-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	33.9435	-118.24653	PC FOR T24 FOR ATM INSTALLATION OUTDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12192	16041-10001-17155	1840 S CENTURY PARK EAST 18TH FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	Changes to approved set. 18th floor.  scope of work includes reduction of luminaire throughout the floor plan, new fixtures were added to the fixture schedule. Changes under delta 6. ***********************************************************************************T-24, PC FOR ENERGY ONLY. INTERIOR FULL FLOOR TENANT IMPROVEMENT FOR AN EXISTING HIGH RISE BUILDING ON THE 18TH FLOOR OFFICE SPACE. TOTAL AFFECTED AREA IS 14846 SQ FT. B # 16016-10000-10294	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12193	19041-10000-21756	241 E CENTURY BLVD #3	90003	8	091-5A205  81	6052016024	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	33.94575	-118.27027	PV1 roof mounted, scope of wokr includes 9 modules (LG solar 335 W) with optimizers (P370), and a central inverter (SE3000H-US). System size is 3KWac/4.02 KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12194	13041-20000-12762	1724 W 24TH ST	90018	8	123B193   392	5058028005	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	34.03436	-118.30104	pv1 2 family dwelling. total system size 4.3 kw. using microinverter enphase m215. nonstandard plan. total of 20 modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12195	17041-10000-21306	4325 S BROADWAY	90037	9	114A203   352	5111009005	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM			Reviewed by Supervisor	07/20/2017 12:00:00 AM	ADDRESS	34.00494	-118.27854	PC FOR POWER. UPGRADING SERVICE FROM 200A TO 600A 120/240V FOR A MIXED USED BUILDING. ALL LOADS ARE EXISITING TO REMAIN. SCOPE INCULDES UPGRADING APARTMENTS  AND HOUSE PANELS, WITH NO NEW CIRUCUITS ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12196	17041-20001-30883	10520 N COMMERCE AVE	91042	7	207B197  1399	2566007007	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			PC Approved	09/08/2017 12:00:00 AM	ADDRESS	34.26	-118.28839	Expedited plan check fee.PV1.  Install 12.42 kW DC/11.52 kW AC roof mounted grid tied PV system.  (36) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12197	14041-20000-00799	12041 W WILSHIRE BLVD #100	90049	11	126B145    53	4265016046	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	PIN	34.04519158	-118.46671786	"Change to lighting in an existing Yoga Studio.  All circuits are existing.  PLAN CHECK ONLY for Energy.  Permit fees are under INSPECTION.""COMPLY WITH DEPARTMENT ORDER effective date10/26/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""INVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issued with effective date 10/26/2011"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12198	19041-10000-43000	24111 W ALBERS ST	91367	3	171B089   111	2047013019	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.16758	-118.65072	[EPLAN] New roof mounted installations with 38 Pansonic 335 watts modules, 38 Enphase IQ7x microinverters, system size 12.7 KW DC and 10.82 KW AC,  Enphase AC combiner box, and service size 225A. Main panel upgrade is under separate permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12199	15041-20001-16023	11846 N SHOSHONE AVE	91344	12	216B129   331	2601041057	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	34.28637	-118.51615	Supplemental application for expedite fees only.  Installation of roof mounted solar PV array.  Total system size = 15.2 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12200	18041-20000-37697	4550 N NAGLE AVE	91423	4	168B157   900	2360020028	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.15323	-118.4235	Plan check for PV roof mounted system, system size: 11.5KW DC, 10.78KW AC with 35 PV Modules and 1 inverter(11.4kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12201	11041-20000-18928	2000 S COTNER AVE	90025	5	126B153   513	4323024038	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM			PC Approved	09/07/2011 12:00:00 AM	ADDRESS	34.0421	-118.44158	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING  FOR CHANGE OF USE FROM RETAIL TO GYM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12202	15041-20000-13350	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Issued	07/07/2015 12:00:00 AM	ADDRESS	34.01768	-118.42494	Plan check for power and energy. Project site is an existing school. Project scope is the installation of (1) 150 kVA transformer, (1) 200-amp panel, and associated loads. The feeder on the 400-amp panel (DP-2) is being replaced, but the panel will remain in place. Submitted per applicant request. Total lighting area = 935 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12203	15041-20000-06352	6255 W SUNSET BLVD 1030	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for T-24 for existing office  high rise(10th floor). Total area: 4703 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12204	19041-10000-23931	220 W 109TH PL	90061	8	088-5A203 205	6074014034	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Closed	02/26/2020 12:00:00 AM	ADDRESS	33.93642	-118.27696	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 10 MODULES (CANADIAN SOLAR 305), OPTIMIZERS (SEP320) AND A CENTRAL INVERTER (SE3000H-US). SYSTEM SIZE IS 3.05KWdc AND 3KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12205	18041-10000-31229	18240 S WESTERN AVE	90248	15	063B193   290	6108001068	C1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	33.86483	-118.30894	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12206	19041-20000-50852	2422 N APOLLO DR	90046	4	153B177   322	5569015034	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Expired	09/28/2023 12:00:00 AM	ADDRESS	34.11541	-118.36505	PV1 PLAN CHECK FOR NEW ROOF PV AND ESS. PV SYSTEM SIZE IS 11.34 KW DC/10 KW AC. ESS SIZE IS 27 KWH. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS, A 10 KW INVERTER, (2) SUB PANELS, AND (2) 5.8 KVA BATTERIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12207	15041-10000-36509	1107 S VICTORIA AVE	90019	10	129B189   103	5082020002	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.05326	-118.32536	PVI, INSTALL 3.18 KEW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12208	17041-10001-23338	11401 N PORTER RANCH DR BLDG 2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 2 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 2 of 10.  Type III.       Building permit #17010-10000-02378	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12209	17041-10000-04247	10250 W SANTA MONICA BLVD 1705	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR RETAIL TI ""BEAMING"" NEW LIGHTING. PC FOR FIRST TIME TI IN WESTFIELD CENTURY CITY. SUITE 1705"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12210	17041-20000-12711	1060 S BROADWAY	90015	14	126A209   131	5139014011	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.0397	-118.25861	Plan check for a fire alarm system for a 10-story hotel. Fire alarm consists of (1) FACP, (1) annunciator, and (520) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12211	16041-20001-02254	22735 W CANTLAY ST	91307	12	186B097   980	2022003013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.20205	-118.62259	Expedited per customer request.PV1. Plan check for the addition of a 4.2 kW AC PV system onto an existing 4 kW PV system. For a total system size of 8.2 kW. New PV system consists of(20) Kyocera KU265 Modules(1) ABB PVI 4.2 Inverter(1) Bryant 125A Load Center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12212	10041-10001-11082	2701 N SEPULVEDA BLVD	90049	11	156B141    17	4490001015		West Los Angeles				2623.01	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Expired	04/15/2014 12:00:00 AM	ADDRESS	34.12326	-118.4793	design revision fire alarm for a 5 story commercial bldg. 345 devices and1panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12213	14041-10000-32940	1100 S SAN PEDRO ST G12	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.03515	-118.25194	Energy plan check in a commercial area by replacing HID to LED fixture	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12214	14041-10000-00872	2121 S AVENUE OF THE STARS #2050	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	permit to be pulled at EPC counter only. pc for energy only. less than 400A per applicant. TI TO (E) OFFICE. HIRISE # 2050.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12215	16041-10001-39851	4522 W LEXINGTON AVE	90029	13	144B197   313	5542026021	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Apartment			07/16/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	34.09334	-118.28738	revision to an approvet set, change under delta-1. change includes removing tab box only. original scope:Plan check for power and energy. Project site is a new 3-story apartment building: 2 levels of residential over 1 level of parking garage. Total lighting area = 7,857 sq. ft.Note: Building application has been created under 16010-10000-04656	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12216	11041-10000-03977	19718 W SHERMAN WAY	91306	3	183B117    71	2135016020	C4-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	34.20087	-118.56286	ALTERATIONS IN AN EXISTING RETAIL STORE-NEW LIGHTING SYSTEM AND CIRCUITSPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12217	18041-10000-19530	1457 N NORTH MAIN ST	90012	1	135A217    21	5409005030	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.06575	-118.22991	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12218	19041-10000-20430	20118 W ROSCOE BLVD	91306	3	192B113   603	2107001022	P-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM			Corrections Issued	05/30/2019 12:00:00 AM	ADDRESS	34.21995	-118.57178	PC (ENERGY ONLY) FOR PROPOSED ALTERATION TO INSTALL (N) ATM; WORK TO INCLUDE ALTERING (E) WINDOW TO CREATE OPENING FOR ATM. AREA OF SCOPE 120SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12219	18041-10000-41638	767 S ALAMEDA ST #290	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	Energy plan check for an office T.I located on the 2nd floor of a commercial building. Scope includes new lighting and equipment with a total area of 4127-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12220	13041-10000-34191	2800 W BEVERLY BLVD	90057	13	138A203   482	5155014021	C2-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			Corrections Issued	12/15/2013 12:00:00 AM	ADDRESS	34.07025	-118.27894	PV2, Installing a 30 KW DC roof-mounted solar array system for commercial building. (120)modules: Canadian Solar CS6P-250P: 250W, PTC-227. (3 )Transformered Inverters: Fronious 10.03 String inverter. (Plan reviewed by Peter)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12221	19041-10000-52087	3300 N WONDER VIEW PZ	90068	4	157-5A183  25	5579034033	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	02/11/2020 12:00:00 AM		Issued	02/11/2020 12:00:00 AM	ADDRESS	34.12792	-118.34149	$0 FEE DUE TO AB1414. NEW PV1 ROOFTOP  SOLAR SYSTEM USING 401 SOLAR TILES (T SR60T1)  WITH (3) CENTRAL INVERTERS (3 x DELTA M8 6.9) AND FOUR ENERGY STORAGE SYSTEMS (TESLA POWER WALL). TOTAL SYSTEM SIZE IS 23.45  KWDC/20.7KWAC AND TOTAL SQ. FT. 1604.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12222	16041-10000-24620	465 S LA CIENEGA BLVD	90048	5	135B173   130	4334019064	(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.06979	-118.37662	INSTALL NEW LIGHTS ON A CANOPY OVER EXISTING OUTDOOR TERRACE.  ADDITIONAL NEW LOADS < 400A. PC FOR T-24 ONLY, TOTAL AFFECTED AREA: 3,627 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12223	16041-10002-35699	5166 N AVENIDA HACIENDA	91356	3	171B125   434	2161023004	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.16517	-118.5335	PC FOR REVISIONS TO APPROVED SET. SCOPE INCLUDES CHANGES TO MSP SIZED TO REFLECTE CORRECTE SIZE RATED AT 600A. CHANGES TO INCLUDE RESIZING  OF CONDUIT, REVISIONS TO AIC RATING OF EUIPMENT.THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12224	10041-10000-22700	3625 S GRAND AVE	90007	9	118-5A203 223	5122023027	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM			Corrections Issued	11/28/2010 12:00:00 AM	ADDRESS	34.01785	-118.2778	Adding 2 elevators in a public storage building.  Building is high rise. Adding office area.  Plan check for power and T24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12225	17041-10000-06851	333 S GRAND AVE 17th Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Title 24 only in existing space, T.I. office space 17th Floor. Total area: 5,738 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12226	17041-10001-09069	5440 W CENTURY BLVD	90045	11	090B173   124	4129029011	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	33.94511	-118.37573	10/31/17 Changes to an approved set of plan. Changes include remove OS sensors for each of lighting fixtures and use 1 OS sensor for every 2 to 3 fixtures including emergency lighting fixtures in 31,000 sq ft car garage, Changes has been clouded as delta PC8. Type & Number of Lights did not change.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12227	13041-20002-33073	9838 N CHICOPEE AVE	91325	12	201B129   115	2755013018	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	03/21/2014 12:00:00 AM	ADDRESS	34.24986	-118.51353	changes to apprved set of plans. change to service interconnection. no change in pv system. (($0.00 Plan check fee due to Senate Bill)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12228	16041-20000-38403	9941 N COMANCHE AVE	91311	12	201B113    18	2741013018	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.25134	-118.57249	PV1.  Install 4.2 kW DC roof mounted grid-tied PV system.  (14) modules with (1) 3.8 kW central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12229	19041-20000-14004	958 N HYPERION AVE	90029	13	144A201   202	5427013023	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.08904	-118.28115	INSTALLATION OF (2) 13.5KWH TESLA POWER WALLS AND A 125A PV SUB PANEL ON EXISTING SFD WITH EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12230	10041-10001-25842	440 S VERMONT AVE UNIT #110	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	TI IN AN EXISTING RETAIL STORE IN UNIT #110. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12231	14041-20001-24916	7014 S HOOVER ST UNIT 8	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 8.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12232	16041-20000-05886	11141 W SHELDON ST	91352	7	204B173   222	2528017035	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.25363	-118.37433	Plan check for a PV1 ground-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (23) modules. PV system is interconnecting with a 200-amp, center-fed MSP with an existing 150-amp MCB.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12233	12041-10000-09218	735 S BROADWAY	90014	14	127-5A209  71	5144014031	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			04/23/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.04448	-118.2543	Plan check power and energy for new 6 live-work units in an existing building. Site locate in methane buffer zone. New 1000A service. Modification to seperate fire alarm plans have been filed. Commercial spaces future.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12234	16041-20001-15139	10447 N GLORY AVE	91042	7	204B201   117	2565001057	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM			PC Approved	05/31/2016 12:00:00 AM	ADDRESS	34.25888	-118.28112	RSES expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12235	18041-10000-34818	982 S GRAMERCY PL	90019	4	129B193   182	5081032009	R3-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.05312	-118.31309	NEW 6.56 KW ROOF MOUNTED PV SYSTEM WITH 19 AC MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12236	17041-20000-13831	4170 W 5TH ST 1-32	90020	4	135B193   668	5503018008	R4-2	Central	Wilshire	Greater Wilshire		2117.04	Electrical	Electrical	Apartment			04/27/2017 12:00:00 AM	12/27/2018 12:00:00 AM		Issued	12/27/2018 12:00:00 AM	ADDRESS	34.06511	-118.30979	New 32-unit 5-story apartment building with 1200A 208Y/120V service.  Building permit under 16010-10000-05470.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12237	13041-10000-00983	380 WORLD WAY Space  T30	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 744 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE  CONCESSION (Umani Burger).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12238	14041-10000-11778	6301 W WILSHIRE BLVD	90048	5	135B177   475	5510028001	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.06363	-118.36547	TI FOR EXISTING BANK. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12239	14041-20000-09468	4959 N SEPULVEDA BLVD	91403	4	168B145    84	2263039800	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.16056	-118.46638	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. TECH AREA/ OFFICES. NO CHANGE IN OCCUPANCY. < 400 NEWLY CONNECTED LOAD. 1985 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12240	13041-10000-35360	10201 W PICO BLVD BDLG 100-2ND FLR, N	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	PIN	34.05182951	-118.41257696	T24 PART 6 ENERGY TO (E) COMMERCIAL BUILDING. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 5600 SQ FT, WITH EMERGENCY LIGHTING FOR EGRESS PATH. SCOPE OF WORK < 400A. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12241	10041-20001-03994	725 S FIGUEROA ST 5th&6th fl	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			PC Approved	07/21/2010 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check only. Delta 4 revision on panel schedule to reflect as built.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12242	14041-20000-13355	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.06371	-118.3703	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. OFFICES. NOT A PATIENT CARE ACCORDING TO APPLICANT. 2776 SQFT, EMERGENCY LIGHTING. 18TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12243	17041-20003-38052	660 S VETERAN AVE	90024	5	135B149   467	4363013038	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			08/06/2018 12:00:00 AM			PC Approved	08/06/2018 12:00:00 AM	ADDRESS	34.06501	-118.45379	Revisions to approved set.  Change of inverter type, number, and configuration to match to (E) 600A 240V 3ph-4w delta service.  (((Revisions to approved set.  Change of module type to 320W version, module count to (120), change of inverter system to (2) 14.4 kW SolarEdge 3 phase inverters.  Revised SLD details and wiring.  Plan check for solar pv system, roof-mounted array on apartment building.Total system size: 32.4kW ungrounded.(2) 9kW SolarEdge inverters.(1) 14.4kW SolarEdge inverter.(125) 275W pv modules.(125) 300W power optimizers.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12244	19041-20000-43257	21123 W NORDHOFF ST	91311	12	198B105   171	2746010004	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	03/18/2020 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.23562	-118.59352	2000A 480Y/277V 3ph-4w service, distribution, power and lighting for fire damaged building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12245	17041-10000-03696	4322 W WILSHIRE BLVD SUITE 201	90010	4	132B189    51	5090030009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.06163	-118.32226	pc for title -24. Energy only. scope includes new lights and receptacles.Total affected are 2400 sq.ft.(under 2017 energy code)T.I. FOR EXISTING OFFICE (2ND FLOOR, SUITE # 201).  NEW INTERIOR ONBEARING PARTITIONSbl app# 17016-10000-02491	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12246	18041-10000-02086	7410 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20503	-118.49418	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12247	16041-20000-34714	14822 W MAGNOLIA BLVD #1-6	91403	4	171A149    18	2263038006	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/30/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.1647	-118.45604	REPLANCHECK FOR T24 ENERGY DUE TO LOST PLANS. Plan check for Title 24 only. Project site is a new 6-unit apartment building. Service size is 400-amps. Total lighting area = 5,123 sq. ft.Note: Building permit has been issued under 15010-10000-02063	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12248	16041-10000-32059	903 S NEW HAMPSHIRE AVE 1st	90006	10	132B197  1215	5094025086	(T)(Q)R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			09/09/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Closed	07/21/2017 12:00:00 AM	ADDRESS	34.05572	-118.29316	Plan check for Title 24 only in existing space remodeling lunch area. Total area: 790 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12249	19041-30000-14947	2049 S CENTURY PARK EAST 2nd Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site are common area restrooms on the 2nd floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12250	12041-10000-11086	3785 W WILSHIRE BLVD	90010		132B193    30	5503030903							Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM			PC Approved	05/14/2012 12:00:00 AM	ADDRESS	34.06187	-118.30858	title 24 for a four story bldg, installing one light in ground floor bathroom.retail # 4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12251	14041-10000-03980	9419 N BRIGHTWOOD CT	91325	12	198B133   145	2692022012	RE9-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.24162	-118.50337	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 2.81KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12252	14041-20000-08815	800 W 6TH ST SUITE 500	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.05011	-118.2577	Commercial office TI in highrise building.  Title 24 plan check per inspector request for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12253	17041-30001-28178	1800 S AVENUE OF THE STARS STE675&685	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM			Corrections Issued	09/18/2017 12:00:00 AM	ADDRESS	34.06095	-118.41786	Supplemental PC for lost set of plans** Plan check for Title 24 only in existing high-rise office High rise. Total area: 4435 sq ft. Building application number: 17016-10000-18930	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12254	19041-10000-15390	2830 S CENTRAL AVE	90011	9	117A209   110	5119014032	[Q]M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.01575	-118.25594	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12255	13041-10000-13178	6441 N FIGUEROA ST	90042	14	154-5A231  59	5493005009	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.11908	-118.18378	Restaurant remodel.  To add a new toilet, sinks, walk-in cooler, and private dining area and office.  New lighting, receptacles, and new walk-in cooler.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12256	17041-20000-44590	865 N STRADELLA ROAD	90077	5	141B149    49	4369023020	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	34.08531	-118.45267	Plan check for power only. New single family dwelling with basement. 600A 120/208V 3ph 4w service. Building permit application #15010-30000-04704.permit fees paid under building combo permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12257	15041-10001-09767	24454 W CLIPSTONE ST	91367	3	177B089   727	2032013063	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.17841	-118.65709	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECTED WITH MSP.(38) SUNPOWER 327 WATTS MODULES(2) SMA SUNNY BOY INVERTERS 6 AND 5 KW INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12258	19041-20000-05206	6922 W HOLLYWOOD BLVD #101	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM			PC Info Complete	02/13/2019 12:00:00 AM	ADDRESS	34.10137	-118.34103	Plan check for Title 24 Energy only, wiring alteration in existing space, existing lighting fixture to remain. Tenant Improvement remove load and Newly connected load less than 400A. Total area: 1528 sq ft. B#19016-10000-02879	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12259	19041-10000-07943	1340 S HILL ST	90015	14	124-5A207  91	5133002001	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	08/04/2022 12:00:00 AM		Issued	08/04/2022 12:00:00 AM	ADDRESS	34.03663	-118.26277	NEW 7 FLOOR BUILDING (NOT HIGH RISE), 235 UNITS WITH A 4000A SERVICE. Building Permit: 19010-10000-01133	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12260	18041-10000-15511	300 WORLD WAY T.I.	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	33.94502	-118.40714	Plan check for power and energy. Project site is Terminal 3 at LAX. Project scope is a tenant improvement/relocation. Total lighting area = 6,143 sq. ft.Note: Building application has been generated under 18016-10004-03811	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12261	17041-20001-34139	14315 W JOY DR	91331	6	198B153  1027	2644027239	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24174	-118.44502	Changes to an approved set of plans. Equipment ratings have changed and PV system size is now 3.8 kWac.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12262	12041-10000-16670	13419 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Approved	11/21/2012 12:00:00 AM	ADDRESS	34.15778	-118.42532	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12263	18041-10000-22932	12669 N ENCINITAS AVE	91342	7	219B141    70	2604035027	[Q]CM-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.29989	-118.47409	New Fire Alarm system to a new Medical Office Building ( Type of Construction to Type III). (162) devices, (3) Panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12264	13041-20001-33912	1111 W WILSHIRE BLVD 102	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.05259	-118.26348	Plan check for power and energy and T24 for a first time tenant retail store. Total area 1496 sq ft. New 400 A  Gutter.(Review by Mr. Frncis)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12265	17041-10000-33515	2521 N PASADENA AVE	90031	1	139-5A221 148	5205022032	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.0766	-118.21602	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12266	14041-20000-32157	11210 W PEACH GROVE ST	91601	2	168B173   286	2353022026	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			11/19/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	PIN	34.15890512	-118.37505447	New fire alarm system for new 15 unit, three story apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12267	14041-20000-30973	8401 N BURNET AVE	91343	6	192B145   321	2654025022	(T)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.22302	-118.46348	Roof mounted PV system with transformerless inverter.  Total system size 4.2KW.Note: The solar PV installation shall comply with L.A. Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12268	14041-10000-19218	20860 W ROSCOE BLVD	91306	3	192B109   779	2108031011	P-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.21977	-118.58795	Title 24 part 6 plan check only.  Total area = 1,596 kWRemove HID light fixtures and replace with new flourescent fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12269	17041-10000-35957	624 N JUANITA AVE	90004	13	141B197   643	5539023028	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.08256	-118.29038	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12270	15041-10000-38420	2201 E WASHINGTON BLVD	90021	14	118-5A215   6	5167019900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	10/27/2021 12:00:00 AM	ADDRESS	34.01911	-118.23383	PC FOR INSTALLATION OF OPTIONAL STANDBY GENERATOR TO PICK UP ENTIRE SERVICE. INSTALL TRANSFER SWITCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12271	13041-10000-24060	6101 W 83RD PL	90045	11	099B169  1401	4107027018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM			Verifications in Progress	10/22/2013 12:00:00 AM	ADDRESS	33.96305	-118.39178	PV1.  Install 6.615 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter Power-One Aurora PVI-6000-OUTD-US-Z	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12272	14041-10000-30982	615 S MANHATTAN PL	90005	10	135B193   931	5503032012	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Apartment			11/07/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Closed	07/27/2018 12:00:00 AM	ADDRESS	34.06286	-118.3105	Plan check for fire alarm system replacement. Adding 461 new devices and 2 new communication/control panels. Building is R2 occupancy and is a high rise (12 floors).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12273	19041-20000-33377	3976 S COOLIDGE AVE	90066	11	114B157  1309	4214011008	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.00567	-118.42102	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM TO EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK CONSISTS OF (1) BATTERY AND A PANEL. SYSTEM SIZE IS 13.2 KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12274	13041-10000-09028	3550 N TYBURN ST	90065	13	153B209    13	5458003027	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.11966	-118.25273	FOR A HUGE PRINTING PRESS, REPLACING PUMP MODULE, DRYER, MAIN, AND UV SYSTEMTHESE PRINTING PRESS MODULES ARE TO UPGRADE THE PERFORMANCE OF THE PRINTING PRES;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12275	14041-20000-34082	12751 W WEIDNER ST	91331	7	213B161   353	2527025009	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.28173	-118.41108	PV 1 roof mounted system size: 6.0kW with 1 inverter and 34 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12276	14041-20000-07665	15456 W DEVONSHIRE ST	91345	7	204B145   314	2660001001	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.25714	-118.46928	T24 FOR EXISTING RESTAURANT. TOTAL CONNECTED LOAD DOES NOT EXCEED 400A. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12277	18041-20000-48892	14543 W VENTURA BLVD	91403	4	166-5A151  96	2265010005	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.15133	-118.45015	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 2243 SQFT AREA CHANGE OF USE OF EXISTING RETAIL SALES & RESTAURANT TO RESTAUARANT. INTERIOR TENANT IMPROVEMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12278	13041-10000-09939	1439 N POINSETTIA PL 1-39	90046	4	147B181   777	5548019023	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			04/17/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.09717	-118.34858	FULL PLAN CHECK FOR POWER AND ENERGY ON A 39 UNIT APARTMENT. 1600 AMP SERVICE.  1 TYPICAL UNIT PANEL. NOTE TO PLAN CHECKER: FIRE ALARM VARIANCE WILL BE FILED AT A LATER DATE, PHOTOMETRICS AND TITLE 24 CALCULATIONS WILL BE PROVIDED AT A LATER DATE CONTACT EMAIL .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12279	13041-10000-21166	19610 W ROMAR ST	91324	12	204B117   398	2726010013	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.25446	-118.5609	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN. SYSTEM SIZE IS 10.78 KW DC AND 7.5 KW AC. 44 MODULES IN 4 STRINGS OF 11. 1 COMBINER BOX. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: FRONIUS # IG PLUS V 7.5]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12280	13041-10000-24960	1030 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	33.79073	-118.29408	TITLE 24 PLAN CHECK ONLY. EMERGENCY LIGHTING. 2 STORY BUILDING. WORK ON 2ND FLOOR. 2392 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12281	19041-10000-31451	4305 N CLEAR VALLEY DR	91436	5	165B137   238	2284018027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.14913	-118.48564	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 33 MODULES USING P320 OPTIMIZERS, CONNECTED TO EXISTING 200A PANEL  35 roof mounted PV solar panels, 1 panel upgrade to 200A, 1 inverter, system size 10.325	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12282	16041-20000-03262	15148 W BLEDSOE ST	91342	7	222B145   121	2506002030	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.30689	-118.46319	Plan check for power only. Project site is an existing commercial building. Project scope is the replacement of vandalized power distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12283	14041-20000-00506	17247 W INDEX ST	91344	12	210B133    57	2697014024	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.27581	-118.50936	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12284	13041-20000-27740	4650 N BELLAIRE AVE	91604	2	168B161   667	2362024002	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.15545	-118.40928	PV1 7.5KW SYSTEM. 3 STRINGS FOR 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12285	17041-10000-43673	717 N FULLER AVE	90046	5	141B181   458	5526009030	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			Reviewed by Supervisor	12/15/2017 12:00:00 AM	ADDRESS	34.08416	-118.34995	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 39 MODULES (LG LG3602w-G4) AND 39 MICROINVERTERS (ENPHASE IQ6-60-X-US).  SYSTEM SIZE IS 14.04KWdc and 9.36KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12286	13041-20000-34210	9201 N VANALDEN AVE	91324	12	198B121   642	2762035018	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM			Corrections Issued	12/09/2013 12:00:00 AM	ADDRESS	34.23728	-118.54932	New rooftop PV system for an existing sfr.  System uses Enphase microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12287	19041-10000-25641	11479 W KAMLOOPS PL	91342	7	210B169    18	2530015013	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.27639	-118.38195	NEW ROOF MOUNTED 7.04 KW PV SYSTEM WITH 22 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12288	11041-20000-09670	21329 W NORDHOFF ST	91311	12	198B105   169	2746010002	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.23562	-118.59582	T.I. to existing warehouse.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12289	17041-20000-03464	10605 N BALBOA BLVD 2nd flr	91344	12	207B133   738	2695008026	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			Verifications in Progress	06/15/2017 12:00:00 AM	ADDRESS	34.26259	-118.50249	change of use from office from medical office.  plan check for power and energy.  total square footage 3003	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12290	15041-20000-12133	6600 N TOPANGA CANYON BLVD # 1048	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for T-24 only for Barber Lounge.Total area: 980 sq ft. No change of use according to the applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12291	18041-10001-12499	1541 N WILCOX AVE	90028	13	147A187    48	5547017003	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/17/2021 12:00:00 AM	ADDRESS	34.09913	-118.33128	PLAN CHECK FOR POWER AND ENERGY FOR 11 STORY HOTEL WITH 190 UNITS(30 TYPICAL UNITS ) - SERVICE SIZE = 2500A COVERED UNDER ORIGINAL PERMIT. SCOPE INCLUDES FLOOR 1-11 ONLY. BASEMENT LEVELS HAVE BEEN COVERED UNDER ORIGINAL PERMIT. ORIGINAL PERMIT FOR BASEMENT LEVEL SUBMITTAL FOR 3 LEVEL GUARAGE STRUCTURE AS A PART OF HIGHRISE HOTEL. THIS IS A PLAN CHECK ONLY FOR CONDUITS. APPLICANT TO OBTAIN CONDUIT AND PERMIT WITH MODIFICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12292	09041-10004-14607	2190 E 14TH ST	90021	14	120A217    90	5167016024	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.02344	-118.23347	changes to approved set of plans. pc for t24 energy changes only. contracter installed different fixtures from previuos plans. this plan check is for as built plan check. permit already issued. no furthur permits to be issued for this scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12293	10041-10000-09245	1301 S SOTO ST	90023	14	121-5A221 184	5170016029	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	08/31/2010 12:00:00 AM	ADDRESS	34.02612	-118.21991	T.I. to existing restuarant building.  Install general and emergency light.  Plan check for Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12294	19041-20000-48186	14016 W VENTURA BLVD	91423	4	165B153   520	2266015002	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.14893	-118.43785	T24 PLAN CHECK, ENERGY ONLY, LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 3983 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12295	18041-10000-43969	718 S HILL ST 4TH FLOOR	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	04/08/2021 12:00:00 AM	ADDRESS	34.04527	-118.25477	PC FOR A TI-FIRST TIME TENANT (POWER AND ENERGY) FOR A  LOW RISE OFFICE BUILDING. 4TH FLOOR. SCOPE INCLUDE NEW CIRCUITS, RECEPTICAL  AND LIGHTING. TOTAL AFFECTED AREA IS 5823 SQ.FTB# 18016-10002-03643	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12296	16041-30000-18169	8621 S CIMARRON ST	90047	8	097-5A191 328	6036001006	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	33.95925	-118.31623	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (14) modules, (1) combiner box and (1) inverter. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12297	15041-20000-32712	13202 W CHANDLER BLVD	91401	4	171B157   126	2345022020	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.16825	-118.42036	Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (70) modules, (1) combiner box, and (1) load center.Note: $0.00 permit fees due to Senate 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12298	19041-10000-19377	402 W 7TH ST	90731	15	015B201   173	7455005011	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	33.73797	-118.28589	pc (energy only) for coffee shop. area of scope is 3,658sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12299	19041-10000-18852	10465 N SUNLAND BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1032.00	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM			Corrections Issued	05/20/2019 12:00:00 AM	ADDRESS	34.26	-118.32599	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL STORE. TOTAL EFFECTED AREA 14497 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12300	18041-10000-37987	15871 W MULHOLLAND DR	90049	5	159B141   390	4490001009	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.12917	-118.47917	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12301	16041-10000-25104	5300 N LANKERSHIM BLVD #150	91601	2	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.16715	-118.37571	TENANT IMPROVEMENT (EXISTING RESTAURANT) pc for t24 energy only. new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12302	18041-10000-29157	7361 N TOPANGA CANYON BLVD	91303	3	186B101   671	2023005010	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Issued	08/03/2018 12:00:00 AM	ADDRESS	34.20449	-118.60615	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12303	14041-10000-21976	12827 W VICTORY BLVD	91606	2	180B161  1043	2325032012	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	03/26/2015 12:00:00 AM		Issued	03/26/2015 12:00:00 AM	ADDRESS	34.18684	-118.41269	PLANCHECK FOR POWER AND ENERGY.TENANT IMPROVEMENT TO AN EXISTING 8 SCREEN CINEMA. PLACE OF ASSEMBLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12304	11041-10000-23467	717 S CABRILLO AVE SCHOOL	90731	15	015B197   536	7454001001	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	33.73746	-118.29469	NEW FIRE ALARM SYSTEM IN THE CHURCH / SHOOL BUILDINGS.  (THIS PERMIT IS FOR THE ELEMENTRY SCHOOL BUILDING, PERMIT # 11041-10001-23467 WAS ISSUED FOR THE MONSIGNOR SCOTT BUILDING AND PERMIT # 11041-10002-23467 WAS ISSUED FOR THE AUDITORIUM BUILDING).  THE MAIN FACP IS IN THE SCHOOL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12305	17041-20000-18319	9239 N KENNY CT	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.23865	-118.45932	Plan check for solar pv system, roof-mounted on SFD.3.84kW ungrounded sysetm. (12) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12306	16041-20000-25789	11239 N TAMPA AVE	91326	12	210B117    34	2701004013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.27426	-118.55715	Plan check Title 24 only Bathroom remodel space. Total area: 246 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12307	15041-10000-29594	2323 W BEVERLY BLVD	90026	13	136-5A205 194	5157011022	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.01	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	PIN	34.06831816	-118.27324008	PC FOR POWER. UPGRADING SERVICE TO 600A. ADDING NEW PANELS AND LOADS. TOTAL LOAD ADDED IS 183 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12308	14041-10000-17354	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Closed	04/06/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for power and lighting.  Total area = 24,201 sq. ft.Remodel of a public area (basement to 3rd floor) in an existing commercial highrise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12309	13041-20000-00832	5757 W WILSHIRE BLVD STE 6	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			01/11/2013 12:00:00 AM			PC Info Complete	02/12/2013 12:00:00 AM	ADDRESS	34.06259	-118.35341	Relocate Emergency loads to Existing  30kw Generator .   Emergency generator for Medical Ambulatory Surgery Center.  NOT State Licensed Medical, NOT checked for OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12310	17041-10000-20719	6609 N VAN NUYS BLVD	91405	6	180B149   377	2236010007	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.19088	-118.44901	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12311	14041-10000-02479	16940 W DEVONSHIRE ST	91344	12	204B133   217	2685002016	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Info Complete	02/27/2014 12:00:00 AM	ADDRESS	34.25735	-118.50161	T24 PART 6 ENERGY PLAN CHECK ONLY; LIGHTING UPGRADE FOR RALPH STORE. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 25,015 SQ FT. CL devoce is integrated as part of the track light.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12312	14041-20000-22610	9003 N GOTHIC AVE	91343	12	195B137   132	2688033016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.23416	-118.48959	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW(1) ABB PVI-6000-OUTD-US-Z-A transformerless inverter(27) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12313	19041-20000-10952	6121 W SUNSET BLVD	90028	13	147A189   234	5546026044	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Issued	03/27/2019 12:00:00 AM	ADDRESS	34.09818	-118.32309	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12314	11041-10000-19262	1619 N SAN REMO DR	90272	11	132B133    54	4425034016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	01/10/2012 12:00:00 AM	ADDRESS	34.06071	-118.49995	Photovoltaic installation on roof of single family dwelling.  Includes modules, inverters, combiner boxes, and subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12315	14041-10000-06728	1872 N AVENUE 56	90042	14	159A227   338	5480031045	RE11-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Expired	04/21/2016 12:00:00 AM	ADDRESS	34.12863	-118.19635	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL. WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12316	14041-20000-10066	23317 W ARMINTA ST	91304	12	189B093   416	2020024011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.21339	-118.63578	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.7KW AC USING MICROINVERTERS. USING STANDARD PLAN. ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12317	12041-10000-02715	4501 W COLORADO BLVD (B-6)	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	New 5-Story, 87,700 sf Type I-B Office Building (BAXTER B6). EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12318	13041-20000-20637	8655 S SEPULVEDA BLVD	90045	11	096B165   768	4122001003	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Info Complete	10/17/2013 12:00:00 AM	ADDRESS	33.95844	-118.39645	INTERIOR RENOVATION OF RETAIL SPACE. NEW ROSS STORE. EXISTING ELECTRICAL SERVICE BUT NEW DISTRIBUTION AND COMPLETELY NEW WIRING. 1200A. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12319	14041-20000-10160	845 N BUNKER HILL AVE	90012	1	135A213   132	5407007010	R4-1	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Apartment			04/17/2014 12:00:00 AM			Reviewed by Supervisor	05/16/2014 12:00:00 AM	ADDRESS	34.06449	-118.24277	TI IN AN EXISTING 3 STORY, 18 UNIT APARTMENT BUILDING. UPGRADE SERVICE TO 600 AMP, INSTALL NEW SUBPANELS IN EACH UNIT AND HOUSE PANELS. ALL NEW CIRCUITS IN THE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12320	17041-10000-32813	8960 N PATRICK AVE	91331	6	195B161   385	2628014008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.23259	-118.41231	New rooftop solar installation 3.8 kW AC system. (1) inverter, (11) modules , (11) power optomizer	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12321	13041-10000-07914	20282 W VIA MEDICI	91326	12	219B113   131	2701043025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.2941	-118.57584	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW. USING 22 MODULES. STANDARD PLAN CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12322	16041-10000-09546	6600 W SUNSET BLVD 4th FL.	90028	13	147A185    65	5547024032	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.09782	-118.33334	TI on the 4th floor of the (E) commercial build. Install new lights and control receptacles. PC for T-24 only. Total area: 7,743 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12323	16041-20002-45821	13302 1/2 W FILMORE ST	91331	7	210B157   496	2535010009	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	07/11/2022 12:00:00 AM	PIN	34.27080857	-118.42238071	[[ PLANCHECK ONLY FOR PV2.  R1-ZONE WITH COMMERICAL AREA. ORIGINAL PLANCHECK WAS DONE FOR RESIDENTIAL ONLINE. CHANGE OF ADDRESS PERMIT FROM 13302 TO 13302 1/2 FILMORE]]]Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12324	19041-10002-00775	10514 W DUNLEER DR	90064	5	123B161   360	4318037028	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.03512	-118.41433	void.....plan check for a 15.2 KW AC/ 18.6KW DC roofmounted system with (60) modules (2) inverter , and (60) optimizers interconnecting through the main service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12325	11041-10000-08934	17267 W VENTURA BLVD	91316	5	171B133   658	2258012026	(Q)P-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			PC Approved	05/24/2011 12:00:00 AM	ADDRESS	34.16094	-118.5092	T.I.  EXISTING RESTAURANT.  REPLACING LIGHT FIXTURES.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12326	10041-20000-17421	16255 W VENTURA BLVD #100	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.15711	-118.48768	Plan check power and energy for medical office w/eye surgery TI, suite 100. Not check for OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12327	18041-10000-07716	801 S GRAND AVE STE 500	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM			PC Approved	03/02/2018 12:00:00 AM	ADDRESS	34.04581	-118.25842	PC for T24 only for TI to suite 500 in high rise building. Scope includes new lighting, receptacles and reusing existing circuits. B# 18016-10000-02965	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12328	16041-10000-27771	12391 N MONTERO AVE	91342	7	219B161   273	2525028018	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.29485	-118.4098	Remove outdoor HID fixtures and replace  with new LED fixtures - plan check T/24 only. Total area 52902 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12329	13041-10000-02682	3053 N FIERO ST	90065	13	156B209   218	5458004016	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM			PC Approved	02/01/2013 12:00:00 AM	ADDRESS	34.12133	-118.24984	PLAN CHECK FOR TITLE 24 ON A WAREHOUSE INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12330	12041-20000-05615	8900 N DE SOTO AVE BLDG 106	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM			PC Approved	03/12/2012 12:00:00 AM	ADDRESS	34.23162	-118.58832	P/check for lighting compliance, T. I.  manufacturing space. (RELOCATE (E) EQUIPMENT, STORAGE CABINETS AND WORK STATION TO BLDG 106; NEW CANOPY; NEW STUD WALL ENCLOSURE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12331	16041-20000-12520	10334 N MCCLEMONT AVE	91042	7	204B197   658	2558016006	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.25698	-118.29497	PV1. ROOMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.92 KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12332	13041-20000-07606	2700 S ROSCOMARE ROAD PV-1	90077	5	156B145    46	4378014007	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Expired	04/24/2015 12:00:00 AM	ADDRESS	34.12601	-118.46337	microinverter standard plan. 2.592kW combined.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12333	14041-20000-12014	12650 W SANDHILL LANE Unit 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.9774	-118.4142	Roof mounted PV system with system size 1.38KW.  Using transformerless inverters.  This part of a series set of submittal.  This PV system to interconnect to common service.  This is project 2 of 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12334	15041-10000-13405	606 N ARDMORE AVE	90004	13	141B193   871	5520002021	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Expired	05/30/2017 12:00:00 AM	ADDRESS	34.08187	-118.30153	PV1, ROOF MOUNTED SYSTEM. TOTAL SIZE 5.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12335	16041-10011-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	02/19/2020 12:00:00 AM		Issued	02/19/2020 12:00:00 AM	ADDRESS	34.23567	-118.5584	DELTA 47 CHANGES TO APPROVED SET TO ADD ONE DEDICATED CIRCUIT FOR ATT COMMUNICATION EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12336	17041-20000-20266	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Issued	06/15/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	pv1install roof mounted pv system sized 10kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12337	16041-10000-23195	16702 S VERMONT AVE 1-6	90247	15	066B197    92	6121008038	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Apartment			07/01/2016 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	33.87938	-118.29102	6 UNIT APPTMENT (5 LIVE WORK AND 1 DWELING UNIT) - FULL PLAN CHECK.600A SERVICE,  PLAN CHECK FOR TITLE 24 (1730 SQ. FT.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12338	10041-20004-18676	818-848 E 29TH ST	90011	9	118-5A207 325	5128015052	(T)(Q)R3-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	ADDRESS	34.01762	-118.26081	Changes to approved set of plans. Original permit on 10041-10000-18676.Installation of two photovoltaic arrays of micro inverters on the roofs of two carports.  the arrays supply existing distribution panels as shown on the plans.  System grounding and equipment grounding subject to inspectors's approval.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12339	13041-10000-27227	6921 S LA TIJERA BLVD	90045	11	102B173   156	4103003015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	33.97563	-118.37395	TI 99 cents store.  power and T24 .  plann submitted originaly under 13041-10000-22475.  orginal engineer has chnaged .  new submittal was requested.  service is existing fo rthe building . new MDP panel and circuits. shorth circuit is based on 65000 amp.  series rated used and breakers indicated on MDP panels .  lighting is 277v step transformer is used.  charge of submittal per hour based on original submittal.  FA variance was submitted to seperate plan.  Issue permit under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12340	16041-20000-43148	6225 N CORBIN AVE	91356	3	177B117   332	2153022004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.18332	-118.56246	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12341	18041-10000-32616	20463 W GAULT ST	91306	3	183B109   218	2136003019	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Issued	08/27/2018 12:00:00 AM	ADDRESS	34.19936	-118.5794	PV1, NEW ROOF MOUNTED PV SYSTEM TO A SINGLE FAMILY RESIDENCE. SCOPE OF WORK INCLUDES (31) SOLAR MODULES (31)POWER OPTIMIZERS AND (1) 7.6KW INVERTER. TOTAL SYSTEM SIZE IS 9.15KWDC AND 7.6KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12342	17041-20000-45733	18801 W PASADERO DR	91356	3	165B121   330	2177020011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	03/17/2018 12:00:00 AM	ADDRESS	34.14847	-118.54338	"'0$ permit fees due to senate bill 1222""Plan check for a SFD roof-mounted PV system and DC coupled battery backup system. PV system size is 15.2 kWac and consists of (2) 7.6kW inverters, (40) 335W pv modules, (40) 370W power optimizers, (2) 5kW batteries, and (3) load centers."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12343	10041-20000-09786	737 W 28TH ST	90007	8	121-5A201  91	5123016401	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM	07/21/2010 12:00:00 AM		Permit Finaled	01/07/2011 12:00:00 AM	ADDRESS	34.02769	-118.28069	Plan check power for service upgrade and switchgear from 400A to 600A at Gamma Phi Beta Sorority House.  New panels. Existing feeder, circuits, and equipment. Misc permit for replacing existing circuit breakers. New panels under permit #10041-70000-09837	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12344	18041-10001-19484	1835 W 88TH ST	90047	8	096A193    36	6036011007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	33.95827	-118.31038	(THIS IS PLAN CHECK ONLY, PERMIT IS COVERED UNDER MASTER#) PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES ADDITION OF 5 MODULES, CHANGE TO OPTIMIZERS SIZE AND RELOCATION OF MSP AND INVERTER LOCATION.NEW SYSTME DC SIZE CHANGES TO 8.37KWDCAC RATING STAYS THE SAME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12345	17041-10000-05904	9861 N RESEDA BLVD	91324	12	201B125    97	2763037900	[Q]PF-1XL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.24963	-118.53631	PC FOR NEW FA SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12346	12041-10000-19695	10604 S HICKORY ST	90002	15	090A215   542	6066010039	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM			Reviewed by Supervisor	09/14/2012 12:00:00 AM	ADDRESS	33.93962	-118.23559	New 4.5kw rooftop, photovoltaic system for an existing single family dwelling.  System uses transformerless inverter and is ungrounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12347	15041-20000-01817	9410 N TOPANGA CANYON BLVD #200	91311	12	198B101   334	2746013038	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.2412	-118.60593	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN LOBBY AREA. LIGHITNG DESIGNED BY C-10 CONTRACTOR. INSPECTOR VERIFY PERMIT ISSUED TO C-10.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12348	14041-10000-23566	13907 W DAVENTRY ST	91331	7	207B153   325	2618003020	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.26558	-118.43589	PV1, INSTALL 13.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(50) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER: SOLAREDGE SE6000A-US-ZB-Upermit fee is 0.00 due to Senate bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12349	16041-20000-44993	5400 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.06201	-118.34659	Plan check for power and energy. First time tenant - new restaurant. 5,459sqft.Note: Building application has been generated under 16016-10000-31045	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12350	18041-10000-19246	1150 S OLIVE ST 1650	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.03962	-118.26181	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT AT SPACE # 1650 OF OFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1958 SQ. FT. B#18016-10000-14338	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12351	19041-20001-05908	17438 W HATTERAS ST	91316	5	174B129   231	2254022002	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.17603	-118.5136	3/19/19changes to an approved set of plans.  changes to reflect field conditions, removal of (1) load center.this is plan check only.  ((((PV1.  Install 8.775 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (27) modules with 7.6 kW rated string inverter.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12352	16041-10000-02660	854 W DOWNEY WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM			PC Info Complete	01/25/2016 12:00:00 AM	ADDRESS	34.02013	-118.28757	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES FOR THREE OFFICE ROOMS. TOTAL AFFECTED AREA IS 486 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12353	10041-10000-05901	8100 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2766.02, 2780.00	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	33.95164	-118.43579	Install 8 new construction trailers in LAX (LAWA). Each trailer has 1 panel, 6 circuits & 1 AC unit.  The trailers are prefabricated and are approved by the state.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12354	17041-20000-35690	431 S HARVARD BLVD 1-43	90020	10	135B193   548	5503011023	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.06623	-118.30429	0$ PERMIT DUE TO SENATE BILL 1222PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 32.98 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12355	13041-20002-21950	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Approved	07/14/2014 12:00:00 AM	ADDRESS	34.2312	-118.36756	Modifications to approved set.  Revised single line diagram - deletion of feeders for several tenants, reorganization of demising walls.  DEMO INTERIOR OF FORMER RALPHS MARKET. CREATE 7 NEW LEASE SPACES, 3 OF THEM SHELL ONLY AND THE REST TI IMPROVEMENTS. REMODEL EXTERIOR CANOPY AND PARKING LOT. NEW 120/208 2500A SERVICE. (((pc for changes to approved set of plans. changes clouded delta D, change to service section. reduction in design. original permit fee to be recalculated and issued under inspection. this application is for plan check only for changes. ))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12356	17041-10000-04470	421 N HAWAIIAN AVE	90744	15	027B201   421	7417005901	[Q]RD2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM				Installation of a new fire alarm in building 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12357	14041-10000-31828	3013 S BUDLONG AVE	90007	8	120B197   422	5040023020	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.02686	-118.29603	Installation of roof mounted solar PV array.  Total system size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12358	12041-10000-06468	1900 S AVENUE OF THE STARS #340	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	04/20/2012 12:00:00 AM	ADDRESS	34.05979	-118.41671	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO EXISTING OFFICE AREA SUITE #340. PERMIT FOR NEW BRANCH CIRCUITS, LIGHTING,  RECEPTACLES, AND SWITCHES ON EXISTING CIRCUITS. LESS THAN 400A LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12359	15041-10001-30970	11455 W BURBANK BLVD Bldg C	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	08/17/16Changes to an approved set for Church of Scientology-Area C. All changes are clouded under 9. Changes include revising the single line diagram, panels schedules, and lighting floor plans. (((((TI to an exisiting religious assembly site (2-story building), Church of Scientology-Area C. New 600 Amp service, all equipment is new. Full Plan Check. Total Sq ft = 29,141.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12360	15041-10001-01496	9301 N TAMPA AVE #210	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Info Complete	08/31/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	(8/21/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 14. Plan check for power and energy. Tenant improvement of existing restaurant to a Red Robin.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12361	18041-10000-46416	10950 S CENTRAL AVE	90059	15	088-5A211 269	6070006005	MR1-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.93574	-118.25399	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12362	17041-20001-09891	12601 W PIERCE ST 41, 42, 53	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 41, 42, and 53).21kW ungrounded system. (42) AP Systems YC500i microinverters. (84) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12363	13041-10000-03572	10338 N OSO AVE	91311	12	204B113    78	2707016013	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.259	-118.57521	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.55KW. USING 39 PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12364	18041-20000-44640	3041 S QUEENSBURY DR	90064	5	123B161   215	4316004002	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	12/29/2018 12:00:00 AM	ADDRESS	34.03594	-118.40726	PV1.  Install 5.40 kW roof mounted grid tied PV system.  (15) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12365	16041-20000-37983	11019 N CARDAMINE DR	91042	7	210B197   331	2552027012	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	Yes	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.26919	-118.29731	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (24) modules, (24) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12366	12041-10000-19502	210 S COMMONWEALTH AVE	90004	13	136-5A201  46	5501019025	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			08/17/2012 12:00:00 AM	09/26/2012 12:00:00 AM		Permit Closed	09/25/2014 12:00:00 AM	ADDRESS	34.07002	-118.28552	Plan check new 3.84KW roof mounted photovoltaic system for existing apartment building. (Aurora transformerless inverter, two strings)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12367	10041-10000-09519	1943 S PELHAM AVE	90025	5	129B157   659	4321008011	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			05/20/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.04968	-118.43021	NEW 7 UNIT APARTMENT BUILDING. METHANE ZONE - OUTDOOR SERVICE.  Variance was submitted for separate fire alarm system on August 25, 2010.  Methane mitigation by others.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12368	16041-20000-07504	970 N MONUMENT ST 216	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.04646	-118.52393	Plan check for energy only. TI for beauty salon. New lighting. 1,185sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12369	14041-10002-33281	800 W OLYMPIC BLVD A120	90015	9	127-5A205 519	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.04484	-118.26453	Modification to an approved set by changing light fixture and the quantity on the floor plan. Total area also being readjusted . All changes on this application are under delta-4 only. Additional permit fees per applicant request.  (((Changes to approved set.  New lighting layout.*****Previous work description*****TI for remodeling of restaurant - scope of work is lighting only per applicant.  Plan check for energy.  Emergency lighting existing to remain per applicant.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12370	14041-20000-03397	21800 W OXNARD ST Suite 600	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.17898	-118.60253	TI FOR EXISTING OFFICE SPACE REMODEL. ALL LIGHTS ARE EXISTING ONLY RELOCATING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12371	15041-20000-13200	5629 N CORTEEN PL	91607	2	174B165   645	2340019006	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.17303	-118.4021	pv1 sfd total system size 5kw ac using single inverter. nonstandard plan 22 modules total.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12372	14041-10001-03918	10375 W GLENBARR AVE	90064	5	126B161   221	4318032004	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.04029	-118.41016	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLARSYSTEM. NEGATIVELY GROUNDED SYSTEM. SYSTEM SIZE: 10KW.(40) RENESOLA JC250 (2) SMA SB5000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12373	17041-10000-20440	1875 S CENTURY PARK EAST #950	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.06115	-118.41457	Title 24 plan check.  T.I. to office space in existing commercial highrise.  New lighting and receptacles.  Total area = 900 sq. ft.       Building permit #17016-10000-09936	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12374	19041-20000-22803	425 W 14TH ST	90731	15	012B201   144	7456016011	R2-1XL-CPIO	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.73135	-118.28632	Plan check for a PV1 roof-mounted PV system. System size is 4.62 kWdc/3 kWac and consists of (1) inverter and (14) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12375	18041-10000-30127	6741 W 86TH PL	90045	11	096B161   683	4122014022	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Apartment			08/09/2018 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	33.95939	-118.40801	PC FOR T24 ENERGY ONLY FOR APARTMNET COMMON STAIRWELL AND OUTDOOR LIGHTS. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 2846 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12376	10041-10000-10557	360 S ALVARADO ST	90057	1	133-5A205  85	5154028029	C2-1	Central	Westlake		YES	2089.03	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.0613	-118.27349	New Coin Laundry.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12377	12041-10000-17878	1930 S CENTURY PARK WEST	90025	5	132B157   646	4319003063	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	PIN	34.05705589	-118.41909499	PLAN CHECK POWER AND ENERGY FOR NEW WESTFIELD PARKING BUILDING WITH 800A SERVICE SUPPLIED FROM EXISTING ELECTRICAL ROOM LOCATED AT THE MALL BUILDING. SITE LOCATED IN METHANE ZONE. VARIANCE TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12378	10041-10000-09529	10250 W SANTA MONICA BLVD 206	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGE OF USE FROM RETAIL TO RESTAURANT. 1968 sq. ft.  EPC for power  and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12379	15041-20000-29655	333 S GRAND AVE 32nd Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Issued	09/09/2015 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for TITLE 24 open office. Retrofit existing light fixtures to dimmable. Emergency is existing to remain. Total sqft. 537.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12380	16041-10000-41422	3640 N BARHAM BLVD BLDG R	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.13874	-118.34147	PC FOR NEW PANELS, STACKED WASHERS & DRYERS IN CERTAIN APT. UNITS IN BUILDING R OF CAMPUS STYLE COMPLEX. THIS IS BUILDING 3/6(Add 1 laundry ckt and 1 microwave ckt to all 33 units in the building, total new 66 ckt in this building.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12381	19041-10000-03122	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC t-24 only for Hawain LA in LAX terminal 5. alteration, fixtuers relocation. 903sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12382	10041-10000-25257	121 N LA CIENEGA BLVD # 814	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.07484	-118.37674	T.I. REMODEL OF (E) RETAIL SPACE INCLUDING DOORS, PARTITIONS, CEILING, LIGHTING, FIXTURES, MED WORK. 1,727 SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12383	11041-10000-25742	14356 W TYLER ST	91342	7	225B153    87	2504011108	RA-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.31697	-118.4455	Plan check for 8.695 KW roof mounted photovoltaic system for single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12384	19041-10000-11710	3300 S KELTON AVE	90034	5	120B161   664	4254017001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.02509	-118.41883	[ePlan]  New rooftop 3.8 kW PV1 and (1) ESS. Installation consist of (1) 3.8 kW AC inverter, (13) modules, (13) P400 optimizer, (1) ESS @ 14kWh , (1) 200A  load center. System connect to (E) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12385	11041-20000-27628	101 S THE GROVE DR Space K-10	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.07256	-118.35874	Tenant Improvement.  Existing retail space # K-10.  Banana Republic to occupy space.  Plan check is for power and energy.  NOTE TO PLAN CHECKER:  APPLICANT BROUGHT A PRE-CUT CHECK.  VERIFY FEES DURING PLAN CHECK PROCESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12386	19041-20001-04643	1130 S RIDGELEY DR	90019	4	132B177  1180	5085008012	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.05487	-118.35328	pc for pv system. system include 42 modules (sunpower spr-x22-360-d-ac). 1-125AMP panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12387	12041-20000-25365	16607 W CALNEVA DR	91436	5	159B137   321	2293009025	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.1326	-118.49471	Plan check for roof-mounted PV. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12388	12041-20000-08303	536 W AVENUE 46	90065	1	148-5A223  71	5466030023	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM			Reviewed by Supervisor	05/22/2012 12:00:00 AM	ADDRESS	34.10258	-118.21149	Installation of photovoltaic system on roof mounted trellis system using enphase m215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12389	16041-20000-40326	1408 N POINSETTIA PL Unit #E	90046	4	147B181   927	5548019036	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.09607	-118.3481	Plan check for power only. New SFD - unit E - part of 5 attached SFDs fed from (N) common 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12390	13041-10000-11576	9232 SCOTMONT DR	91042	2	198B201   435	2572048020	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	PIN	34.23675283	-118.27609272	PV1, single story house.  3.2 kw dc system size.  {15 modules: LG260S1C-G3} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12391	16041-20000-08072	4035 N DENNY AVE	91604	2	162B177   181	2423032006	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	34.1429	-118.36496	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12392	14041-10000-25479	5037 N MAMMOTH AVE	91423	4	171B153   700	2269003020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.16236	-118.43253	Standard Plan PV1 roof-mounted including (2) 3.8kw inverters, (38) Kyocera KD255 modules and power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12393	18041-10000-05560	2025 S AVENUE OF THE STARS Level B-4-to Level 2	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	10/14/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	PC for Power and Energy for a new 4 level Subterranean parking garage. Scope includes two new 4160V MV services/switchgears installed on 4 levels of parking structure to supply power to the nearby residential North ( 18041-10K-05224) and South ( 18041-10K-05235) Towers having apartment  units. Also, installing new distribution boards, new panels, new circuits, and lighting. Total affected area is 392672 Sq. FT.   B#15010-10000-02798	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12394	13041-20000-22624	4612 N WOLFE WAY	91364	3	168A109   150	2172013044	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.15381	-118.58882	New 5kw UNGROUNDED PV system.  Rooftop mounted on an existing sfr.  Plan check/Permit is for PV System only, NOT for service upgrades or derating of main breaker.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12395	19041-10000-12921	146 S VERMONT AVE	90004	13	138B197  1127	5501012024	C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM			PC Info Complete	04/09/2019 12:00:00 AM	ADDRESS	34.07152	-118.29146	ENERGY PLAN CHECK FOR A CHANGE OF USE FROM RETAIL TO OFFICE. SCOPE INLCUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 1915-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12396	19041-10000-42191	8505 S SARAN DR	90293	11	096B153   421	4115025016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	33.96028	-118.43277	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12397	11041-10000-12196	6701 S CENTER DR WEST	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Expired	07/08/2013 12:00:00 AM	ADDRESS	33.97907	-118.39369	T.I.  on the first floor of a high rise office building.  Putting in new light fixtures.  Plan check is for title 24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12398	13041-20000-18226	14277 W SAYRE ST PV-1	91342	7	219B153    52	2508022032	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.30068	-118.44466	PV1 SINLGE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.5 KW. USING 17 MODULES. TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12399	11041-10000-00638	800 S HOPE ST	90017	9	129A209   202	5144020900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	05/02/2011 12:00:00 AM	ADDRESS	34.0463	-118.25904	new fire alarm for 8 story bldg , 330 devices and one panel. high rise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12400	17041-20000-24959	1747 S WESTWOOD BLVD	90024	5	129B153   354	4324028047	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.05102	-118.43838	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,905 sq. ft.Note: Building permit has been issued under 17016-20000-20326	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12401	13041-10000-29775	1714 S MERMAID DR	90732	15	012B189   114	7562024025	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	33.72894	-118.32206	PV1 ROOF-MOUNTED SOLAR INSTALLATION TO INTERCONNECT WITH EXISTING 100A MAIN SERVICE. SYSTEM SIZE IS 6.048 KW AC. MICROINVERTER STANDARD PLAN WITH 28 MODULES (TRINA SOLAR # TSM-240PA05.18) AND 28 ENPHASE M215 MICROINVERTERS.PANEL UPGRADE FROM 100A TO 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12402	15041-10002-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta 35 CHANGES TO PERMITTED SET OF PLANS  ALL CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA 35 CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12403	11041-20000-26623	4267 S CHASE AVE	90066	11	108B157   708	4231009028	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2011 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	05/07/2012 12:00:00 AM	ADDRESS	33.99257	-118.42966	New 4.7 KW roof mounted PV system for a single family residence.  Applicant is using the M215 microinverter.  A variance was filed to use the microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12404	12041-10000-03242	350 S BIXEL ST #200	90017	1	132A209    99	5152014038	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	03/23/2012 12:00:00 AM	ADDRESS	34.05673	-118.26007	Relocation of light fixtures and new receptacles using existing circuits.  PLAN CHECK ONLY for Energy, with Emergency lighting.   ((Permit is under Inspection))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12405	18041-10000-06208	5445 W HOLLYWOOD BLVD STE D	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			PC Info Complete	02/20/2018 12:00:00 AM	ADDRESS	34.10195	-118.3085	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING LIGHTING FIXTURES. TOTAL AFFECTED AREA IS 4049 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12406	12041-20000-19302	7800 N WOODLEY AVE	91406	6	189B141   290	2206009901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00, 1275.10	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.21161	-118.48344	T-24 and emergency lighting plan check for 22000 square foot warehouse area of existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12407	17041-10000-03657	18207 W SHEFFIELD LANE	91326	12	213B125    19	2870019019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Re-Activate Permit	05/30/2018 12:00:00 AM	ADDRESS	34.28386	-118.53093	PC for a new PV roof mounted solar system in single family home. Installing 38 Microinverterters rated at 250 W each. Total size of the system: 9.50 KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12408	17041-20002-44865	23002 W SYLVAN ST	91367	3	177B097   149	2039010028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	PIN	34.1842535	-118.62796555	Revision to approved set.  Relocation of equipment to match DWP meter spot.  $0 plan check fee per State Senate Bill SB 1222.  (((PV1.  Install 24.08 kW roof mounted grid tied PV system.  (72) AC modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12409	14041-20000-35840	8822 N BURNET AVE	91343	6	195B145   664	2654007164	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Apartment			12/30/2014 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.23069	-118.46313	Plan check for power and energy. New 3-story 20-unit apartment building w/800A service. 20 APARTMENT UNITS ARE ON 2ND & 3RD FLOORS, REC ROOM/LOBBY/PARKING GARAGE ARE ON 1ST FLOOR @ GRADE. 24,000 SF. Fire Alarm variance is on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12410	19041-10000-16255	10952 W SANTA MONICA BLVD	90025	5	129B153   687	4323007005	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.04868	-118.43959	PC ENERGY ONLY Change of use from Wholesale Office to Catering Shop. SCOPE OF WORK AREA 925SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12411	15041-20001-38832	15800 W ROSCOE BLVD	91406	6	192B141   492	2673021041	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.2212	-118.47638	Expedite per applicant request{{{{{{{Plan check for PV roof mounted system. System size: 1,109kW(1MegaW) with 3,580 modules (Canadian Solar Max Power CS6X-31OP) and 24 inverters (CHINT CPS SCA36KTL-DO/US) connected to  new 1,600A switch gear. Service size: 4,000A.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12412	14041-20000-19565	17142 W LISETTE ST	91344	12	222B133   529	2602018004	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.30268	-118.50598	PV1Microinverter standard plan. Install roof-mounted solar array on SFD. System size: 4.95kW(23) EnPhase M215-IG microinverters(23) Hyundai HIS-S265MG pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12413	16041-10000-19596	1452 S BEDFORD ST 1-6	90035	5	129B169   281	4303018028	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			06/03/2016 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	03/30/2021 12:00:00 AM	ADDRESS	34.05252	-118.38062	APRTMENT HOUSE OVER BASEMENT GARAGE.FULL ELECTRICAL PLAN CHECK & TITLE 24 FOR GARAGE AND OUTDOOR LIGHTING(8721 SQ. FT.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12414	16041-20001-21770	7875 N FULTON AVE	91605	2	189B157   599	2303004003	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.21374	-118.4208	EXPEDITEPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12415	16041-20000-02265	3138 W PICO BLVD	90019	10	129B193  1332	5073008001	C2-1VL	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.04701	-118.31048	Plan check for power only in existing system T.I. Adding 800A distribution equipment for laundromat. Total load 625A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12416	17041-20003-05715	14006 W RIVERSIDE DR STE 245A	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	8.2.2017 - Plan check only for changes to approved set - update plans to reflect as built conditions (relocating drinking fountain). No change to lighting design. Changes clouded delta 6.=======6/28/17changes to an approved set of plans.  changes include different light fixtures.  this is plan check only.   (((Plan check for Title 24 only in existing space T.I. retail. Total area: 3,609 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12417	14041-20000-32638	715 N RIDGEWOOD PL	90038	13	141B189   251	5535002023	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.08399	-118.31475	PV2. ROOFMOUNTED TRANSFORMERED INVERTER ON AN APARTMENT BUILDING. SYSTEM SIZE  7KW.(24) SLK60L6P MODULES(1) SMA 7000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12418	17041-10000-35983	3431 N PORTOLA AVE	90032	14	142-5A235  90	5218016008	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.08582	-118.17274	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12419	18041-20000-33852	1841 S MESA ST LOT 22	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	33.7271	-118.28613	pv1install roof mounted pv system sized 2.8KW AC interconnected with msp.  standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12420	11041-10000-02640	2032 E 1ST ST	90033	14	127-5A223  85	5183008004	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.10	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	ADDRESS	34.04486	-118.21409	New 600 Amp service. All panels & branch circuits are existing. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12421	08041-10002-20051	531 S SAN JULIAN ST 1-96	90013	9	127-5A213 259	5148014009	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			09/01/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	09/28/2010 12:00:00 AM	ADDRESS	34.04385	-118.24577	Plan check is for Delta 3 modifications on the plan.  Delta 3 includes addtion of a mircro wave circuit in each dwelling unit.  Delta 3 also applies to other changes.  Dwelling unit loads are reduced, while common area loads have increased.  The building is a identified as :  AFFORDABLE HOUSING PROJECT-  NEW 6 LEVELS MULTI-FAMILY RESIDENTIAL BLDG (5-levels of Type IIIA over 1-level of Type IA podium) OVER TWO LEVELS OF BASEMENT PKG.  TOTAL OF 96 SINGLE ROOM OCCUPANCY UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12422	16041-10000-39906	14853 W SATICOY ST	91405	6	186B149   176	2210033011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.20859	-118.45717	PV1 roof mounted solar system installation to a single family home. Installing a 6.0 Kw inverter being fed by 22 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12423	18041-10000-36458	4334 N WOODMAN AVE	91423	4	165B157   522	2360006008	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Issued	09/25/2018 12:00:00 AM	ADDRESS	34.14899	-118.43103	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12424	17041-10000-10487	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 only for Tenant improvement for various airlines at TBIT and Bradley East (Level 4) and North Concourse (N4, Level 3). total sq. ft. 5735	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12425	19041-20000-37178	6701 S CENTER DR WEST 9th floor	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	Restroom remodel on 9th floor of (E) office building P.C for title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12426	13041-10000-04239	1436 W COLORADO BLVD	90041	14	162A227   114	5690005011	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM			PC Approved	02/22/2013 12:00:00 AM	ADDRESS	34.13928	-118.19588	TI OF SCHOOL TO OFFICE SPACE. NO INCREASE IN LOAD. PC ONLY FOR T24. TOTAL AREA 1541 SQ FT. PERMIT TO BE ISSUED BY PLAN CHECK STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12427	10041-10000-07510	4846 W PICO BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM	06/17/2010 12:00:00 AM		Permit Finaled	08/06/2010 12:00:00 AM	ADDRESS	34.048	-118.342	Tenant improvement in a restaurant ( Yoshinoya beef bowl )plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12428	18041-20000-41597	6320 N TOPANGA CANYON BLVD ste 1625	91367	3	180B105    60	2146029022	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.18578	-118.60536	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.this is plan check only, permit fees paid under application number 18041-20000-39812	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12429	13041-10000-09992	353 S BROADWAY	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.04991	-118.24934	PLAN CHECK FOR POWER AND ENERGY. EXISTING BUILDING WITH NEW 800A SERVICE AND ELECTRICAL SYSTEM (CORE AND SHELL). MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED. ALL TENANTS LOADS WILL BE FUTURE PLAN CHECK SUBMITTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12430	16041-10002-16332	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	33.76597	-118.28407	for fee only......PV2 5.1 Mega watts roof-mounted system with 23,184 modules, and 64 inverters interconnecting through utility transformers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12431	13041-10000-11582	1351-1355 W COLORADO BLVD	90041	14	162A227    84	5691012001	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.13968	-118.19473	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT TO DIVIDE INTO THREE FUTURE RETAIL SPACES TO EXISTING BUILDING. NEW 800A DELTA SYSTEM SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12432	13041-10000-04198	12474 N BRADFORD PL	91344	12	219B129   416	2608013028	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.29662	-118.51596	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY TWO STORY DWELLING. TOTAL SIZE 3.02KW. USING 14 SOLAR MODULES REC 245 PE. USING MICROINVERTER ENPHASE M215-60-2LL-S22.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12433	19041-20000-22385	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	Plan check for Title 24 only in existing Retail Mall Tenant Improvement. Total area: 27,540 sq ft. Newly connected load less than 400A. B#19016-10000-17319	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12434	19041-20001-44697	1527 N GENESEE AVE	90046	4	147B177   848	5551021015	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM			PC Approved	11/01/2019 12:00:00 AM	ADDRESS	34.09887	-118.35842	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE ON SINGLE LINE, CONDUCTOR SIZE INCREASED FOR CONDUCTOR [E], AND CHANGE TO AC WIRE AMPACITY CALCULATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12435	13041-10000-28407	6333 W 3RD ST UNIT #K7	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.07157	-118.36014	Remodel/Conversion into commercial kitchen (food prep for onsite restaurant).  Title 24 plan check only for new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12436	12041-20000-23460	13451 W FIRTH DR	90210	5	159B157   241	4385002009	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.12946	-118.42647	Photovoltaic system on roof of single family dwelling.  System is Ungrounded.  Extra circuit in permit fees is for monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12437	18041-20000-01018	14711 W ROUND VALLEY DR	91403	4	162B149    65	2276034041	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.1442	-118.45288	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (1) load center, and (45) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12438	10041-10000-21715	5900 N CANOGA AVE	91367	3	177B105   102	2149002015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	01/06/2011 12:00:00 AM	ADDRESS	34.17751	-118.59721	REMODELING OF OFFICES ON THE FIRST THREE FLOORS OF A COMMERCIAL BUILDINGPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12439	13041-20000-20414	14110 W OXNARD ST	91401	4	177B153   868	2245001011	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Approved	07/31/2013 12:00:00 AM	ADDRESS	34.17922	-118.44045	T24 FOR EXISTING RESTAURANT. FIRE DAMAGE IN THE KITCHEN ONLY. 788 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12440	18041-20000-29091	5506 W TUXEDO TER	90068	4	153A191   476	5587028036	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.11187	-118.31467	Plan check for PV roof mounted system, system size: 5.0kW with 20 pv modules and 1 inverter(5.0kW) Cernter feed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12441	10041-10000-12782	500 W WORLD WAY MCP-04	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-04. This applicaation separates MCP-04 from the entire project on PCIS 09041-10001-24166( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12442	16041-10000-20297	1457 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.09731	-118.31598	Installation of new fire alarm system in 5 story office building.  Total system size = 126 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12443	10041-10000-05337	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004031	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Public Safety Only			03/24/2010 12:00:00 AM	03/24/2010 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	replacing  fire alarm panel and devices. at the Hotel Bel-Air Spa. 98 D and 1 p	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12444	17041-20000-23357	16234 W CHATSWORTH ST	91344	12	207B137   475	2679018003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Closed	06/27/2018 12:00:00 AM	ADDRESS	34.26454	-118.4862	PV1.  Install 8.7 kW roof mounted grid tied PV system. Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12445	15041-20000-13705	2072 S PROSSER AVE	90025	5	129B157   619	4317006017	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.04978	-118.42588	PV1. Install roof mounted PV system sized 4.2 kW. Interconnected with main service panel.(20) Trina Solar TSM-250 Modules(1) PVI 4.2 TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12446	18041-20000-38421	5242 W 104TH ST	90045	11	090B173   290	4129035013	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			Ready to Issue	10/16/2018 12:00:00 AM	ADDRESS	33.94183	-118.37188	permit fees $0.00 by state senate bill no. 1222pv2install roof mounted pv system sized 90KW AC interconnected with msp.NOTE:This building has (2) services, 1 phase and 3 phase.  pv system to interconnect both services.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12447	18041-20000-34464	20710 W BEECH CIR #294	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.29262	-118.58465	PV1.  Install 3.02 kW DC roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12448	13041-10000-36319	8783 W PICO BLVD	90035	5	132B169   855	4332015024	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	34.0549	-118.38345	TITLE 24 PART 6 ENERGY PLAN CHECK ONLY FOR (E) SINGLE STORY COMMERCIAL BUILDING. SCOPE OF WORK < 400A. PLAN CHECK FOR ENERGY ONLY. LIGHTING AREA IS APPROX. 1489 SQ FT USING TAILOR METHOD FOR ENERGY COMPLIANCE. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.NOTE: PERMIT FEE CALCULATED UNDER INSPECTION FEE PERIOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12449	11041-10000-27420	2407 N CARMAN CREST DR	90068	4	153B181   265	5572009014	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.11424	-118.34618	New PV system for a single family house. EPC is for power	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12450	18041-20000-19166	30 N LATIMER ROAD	90402	11	126B133     2	4409013013	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	02/09/2021 12:00:00 AM	ADDRESS	34.04484	-118.51179	PV1.  Install 30 kW DC roof mounted grid tied PV system.  (72) modules with (1) 30KW rated string inverters.Fees $90.00 due to California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12451	18041-20000-18433	14841 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29487	-118.4547	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.87kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12452	16041-20001-04648	4542 N SYLMAR AVE	91423	4	168A151   189	2265016014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	34.15423	-118.44637	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (24) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12453	15041-10000-03104	9834 N AMBOY AVE	91331	7	201B161   392	2622019018	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.24898	-118.41868	PV1, 3.8KW AC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE.(13)  MODULES SUNPOWER SPR-327NE-WHT-D (1) INVERTER ABB PV1-3.8-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12454	16041-10000-40320	17655 W DEVONSHIRE ST	91325	12	204B129    58	2733013009	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.25781	-118.51928	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 69075 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12455	18041-20000-14799	20646 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.29405	-118.58394	Plan check for PV roof mounted system. System size: 4.02kW with 12 AC Modules connect to MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12456	18041-10000-27698	2984 N ALLESANDRO ST Unit #200	90039	13	150B213   731	5442024047	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.10578	-118.24435	PC FOR ENERGY ONLY. CONVERT PORTION OF THE (E) MANUFACTURING BUILDING TO (N) OFFICES. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1983 SQ. FT. B#18016-20000-10515	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12457	10041-20000-23568	12450 W BURBANK BLVD Unit P	91607	5	174B165   776	2347001072	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.01	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.17197	-118.40477	T.I. to existing building for a new Subway.  Install new panel, branch circuits, and lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12458	15041-30000-39708	19737 W MALDEN ST	91306	3	192B117   169	2782018022	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.22553	-118.56361	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12459	13041-20000-09735	3450 N VISTA HAVEN ROAD PV 1	91403	4	159B145   309	2279011017	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.13332	-118.46764	ROOF MOUNTED PV SYSTEM. 6.0 KW INVERTER.  Permit was issued on application # 13041-20000-01215.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12460	16041-10000-05102	11764 N GLENOAKS BLVD	91340	7	213B157    42	2524002011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.28404	-118.42238	PV1, INSTALL NEW 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON  A SINGLE FAMILY HOUSE.(13) MODULES: SOLARWORLD SW 250 MONO(1) INVERTER: SOLAREDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12461	16041-20001-06277	18256 W RAYEN ST	91325	12	195B125   444	2769022025	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	34.23175	-118.53152	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (28) modules, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12462	14041-20002-11426	5652 N VANTAGE AVE	91607	2	174B165   538	2340026044	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	34.17364	-118.3975	pc for change in inverter location. provide lockable AC disconnect. This is as built design.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12463	13041-20000-15889	13317 W HARDING ST	91340	7	222B157   661	2513011025	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.30101	-118.42404	New Enphase PV system for a sfr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12464	14041-20000-15599	21820 W BURBANK BLVD #100	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.17228	-118.6032	Commercial office TI in (E) 4-story commercial office building.  Plan check for energy conversation standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12465	19041-20000-31065	21000 W PLUMMER ST	91311	12	198B109    41	2746008014	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.24253	-118.59179	INSTALL (52) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL FOR A COMMERCIAL SINGLE STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12466	17041-20000-21416	21038 W VENTURA BLVD	91364	3	171B105   266	2167024005	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.16656	-118.59206	Plan check for energy only. TI/Change of use from retail to restuarant (Giamela's). New lighting (incl. emergency). 1,597sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12467	17041-30000-29371	10432 N SEPULVEDA BLVD	91345	7	207B145   734	2649019009	C2-1, P-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	PIN	34.26038748	-118.46690796	Plan check for Title 24 only in Tenant improvement to (e) resturant. Total area: 1,825 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12468	16041-10000-40869	13677 W FOOTHILL BLVD #A & B	91342	7	222B157    46	2509015027	(T)C2-1VL, P-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.3084	-118.43122	Plan check for first time tenant for power and energy spaces A and B. Total area: 1,912 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12469	14041-20000-09212	22537 W WELBY WAY	91307	12	180B097    64	2038027028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.19296	-118.61831	PV1Install roof-mounted solar array, interconnect with main panel.(18) Modules - Canadian Solar #CS6P-250PX(1) 4.5kW transformerless inverter - SolarEdge #SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12470	18041-20000-08080	18771 W LOS ALIMOS ST	91326	12	207B121   306	2717024036	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	PIN	34.26539534	-118.54219464	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.875 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12471	17041-10000-26726	725 S FIGUEROA ST SUITE 3380	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	OFFICE TI NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12472	12041-10000-04320	1540 W JOHN S GIBSON BLVD Berths-121-126	90731	15	024B209    15	7440021914		Harbor				9800.31	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	PIN	33.75764336	-118.24932548	NEW 34.5KV SWGR TO SUPPLY 6.6KV SWGR EACH AT BERTH 121-126; THIS IS PHASE 2 OF THE AMP DISTRIBUTION AT EACH OF THE MENTIONED BERTHS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12473	14041-10000-11490	9596 N TUNNEY AVE	91324	12	201B117   499	2761005004	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.24536	-118.55671	PV1 5.225KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(19) inverters: {MICROINVERTER: ENPHASE ENERGY M250-60-2LL-S2X]}]. [(19)modules: {solarworld SunModule SW-275 mono}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12474	19041-20000-51088	2139 N UPPER KRESS ST	90046	4	151-5A173 166	5567002013	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	09/21/2020 12:00:00 AM	ADDRESS	34.10972	-118.37781	PV1.  Install 15.48 kW roof mounted PV system.  (43) modules with (2) 7.7 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12475	17041-10000-21893	4550 W PICO BLVD STE 305	90019	10	129B185  1008	5083033019	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.04842	-118.33486	PC FOR RETAIL TI. TOTAL CONNECTED LOAD <400 AINSTALLING  NEW  PANELS, LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 32911 SQ.FT. COMPLY WITH DEPARTMENT ORDER effective date07/09/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATECEIS Case Numberis 680802BL# 17016-10000-17607	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12476	12041-10000-28137	16545 W VENTURA BLVD	91436	5	168B137   304	2259018022	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM			PC Approved	11/26/2012 12:00:00 AM	ADDRESS	34.15789	-118.49338	PC FOR TITLE 24 ON SINGLE STORY BUILDING. NO EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12477	18041-10000-40802	1211 E WASHINGTON BLVD	90021	14	121-5A211 412	5131003002	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.02492	-118.25099	Energy plan check for a commercial area with new lighting and equipment; total area is 4545-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12478	15041-20000-02895	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	TENANT IMPROVEMENT FOR BUILD OUT OF NEW OFFICE & SHOWROOM WITHING (E) CORE & SHELL BUILDING.  FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.  PC IN ACCORDANE TO 2008 ENERGY DUE TO DATE OF BUILDING SUBMITTALSQUAREFOOTAGE FOR WAREHOUSE UNCONDITION SPACE NOT INCLUDED IN FEES TO BE ADJUSTED AT LATER TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12479	19041-30000-50144	2049 CENTURY PARK EAST 26th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	PIN	34.05864553	-118.41292403	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING,CONTROLS, AND POWER IN RESTROOMS. TOTAL AFFACTED AREA IS 410 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12480	12041-20000-18842	4632 N VISTA DEL MONTE AVE	91403	4	168A151    81	2265012012	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Apartment			08/10/2012 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.15576	-118.44971	34 units apartments variance for fire alarm submitted 8/10/12	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12481	14041-20001-03775	23509 W BALTAR ST PV1	91304	12	189B093   174	2020017038	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	02/15/2014 12:00:00 AM	ADDRESS	34.21622	-118.63904	][][[] EXPEDITED PER APPLICANT REQUEST ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 225A MAIN SERVICE PANEL. 9.5 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS, WITH (38) CANADIAN SOLAR #CS6P-250PX, (38) OP300-MV, (2) 5000A-US-ZB-U SOLAREDGE INVERTERS, (1) 125A LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12482	10041-10002-18851	650 N LA CIENEGA BLVD	90069	5	141B173   519	5528017023	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM			PC Approved	01/18/2011 12:00:00 AM	ADDRESS	34.08325	-118.37631	Change the approved plan. Change the outdoor lighting. EPC is for the change. (((((((((((((((((((TI IN AN EXISTING RESTAURANT. PLAN CHECK FOR T24 AND EMERGENCY LIGHTS.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12483	17041-10000-18480	8820 S SEPULVEDA BLVD	90045	11	096B165   989	4123001032	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Apartment			06/02/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	33.95653	-118.39597	Installation of fire alarm system in new 5 story mixed use apartment building over 2 floors of parking.  Total system size = 380 devices + 12 power supplies and 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12484	13041-10000-26220	100 UNIVERSAL CITY PZ stage  #27	0	4	162B177	2424044015	C2-1, PB-1					1437.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM				replacing high bay luminaires -supplied from existing ckts and lighting area ctrls  for shut-off ctrl;EMERGENCY LUMINAIRES REMAINED THE SAME PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12485	16041-20001-11266	1605 1/2-1607 N LA BREA AVE	90028	4	147B181   392	5548008049	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM			PC Approved	06/22/2016 12:00:00 AM	PIN	34.09999546	-118.34494146	Change of use from retail to massage parlor.  Plan check for energy. Total area: 1,250 sq ftChange of address included.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12486	11041-20000-21521	15760 W VENTURA BLVD Ste 840	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.1552	-118.47684	T.I.  Existing office space replacing the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12487	16041-10004-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	Plan check for changes to an approved set of plan. Changes include addition 2 new circuit for coffee appliance. Changes has been clouded as delta 17.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12488	17041-10000-40645	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Closed	09/17/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	Plan check for Power only, TEMPORARY POWER for the Coliseum. Add (N) 2000A 480/277V dist. board to the existing 5000A service, (7) temp. power panelboards, (3) tower cranes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12489	14041-20000-31963	12205 W VENTURA BLVD	91604	2	162B165   117	2367017007	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM			PC Info Complete	02/25/2015 12:00:00 AM	ADDRESS	34.14344	-118.39864	Plan check for power only. Upgrade service from 400A to 800A. New service distribution equipment. New feeders to existing equipment and panels. 2 new panels. Commercial retail low rise building.Note: Permit to be pull on supplemental application 14041-20001-31963	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12490	13041-20002-17880	11854 W OLYMPIC BLVD	90064	11	123B149   529	4259024004	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.03259	-118.45147	Changes from previously approved plans.  Change in upsizing transformer.  All changes indicate by DELTA 5.  Plan check for power only.*****Original Description*****Change to lighting and loads to an existing commercial retail space.  Full Plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12491	18041-20000-15081	9132 N DE GARMO AVE	91352	6	198B173   110	2408034047	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Closed	10/24/2018 12:00:00 AM	ADDRESS	34.23512	-118.3746	Plan check for energy only in parking lot space outdoor lighting. Methane zone - below grade not classified hazardous per geologist report.  Total area: 11,680 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12492	14041-10000-11112	1351 N RONAN AVE	90744	15	036B205  1271	7415006020	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	33.79014	-118.27298	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12493	16041-10002-21845	400 W WESTMONT DR PV1-PV2	90731	15	024B201   348	7412026017	[Q]M3-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	33.7641	-118.28532	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED ON PLANS. CHANGE TO MAIN SERVICE ENTRANCE DUE TO METHANE BARRIERS. UPDATED INFO ON PLANS AND SERVICE LETTER. CHANGE OF ADDRESS PROVIDED FOR UNIT PV2. UPDATED ENGINEER ON RECORD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12494	15041-20000-19703	10504 N MT GLEASON AVE	91042	7	204B193   134	2557026001	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.25993	-118.30254	Title 24 plan check only.  Total area = 2,242 sq. ft.  T.I. to existing restaraunt space.  New lighting throughout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12495	15041-10000-39864	1031 S GLENDON AVE	90024	5	132B153  1097	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Issued	11/25/2015 12:00:00 AM	ADDRESS	34.06193	-118.44439	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. 16 DEVICES AND 1 FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12496	14041-20001-04456	1550 N OLD OAK ROAD	90049	11	132B137   203	4425025002	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.05997	-118.4963	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 3 STRINGS/ INVERTER. SERVICE INTERCONNECTION TO 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12497	17041-10002-43816	11356 W DONA LOLA DR	91604	2	159B173   400	2380017022	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.13224	-118.37858	expedite per applicant requestNEW ROOFTOP SOLAR SYSTEM CONSIST OF 52 MODULES (SILFAB SLG-M 370 WATT) AND 52 MICROINVERTERS (ENPHASE IQ6PLUS-72-2-US).  SYSTEM SIZE IS 19.24KWdc and 15.08KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12498	19041-10000-00758	841 S LA PALOMA AVE	90744	15	024B205    22	7440014904	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	33.76076	-118.26497	PC T-24 ONLY FOR REMODEL OF EXISTING 2135SF SPACE, OFFICE/STORAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12499	12041-20000-19819	5112 N QUAKERTOWN AVE Main house	91364	3	171B113   352	2166008010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.1636	-118.57048	Single family dwelling solar installation.  One inverter and 12 modules are located at the garage.  The main circuit breaker at the existing residential service was reduced to 150 amperes.  One circuit added at the existing service for PV monitoring system.  The garage inverter and modules permitted on application number 12041-20000-26208.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12500	13041-10000-32332	408 N LUCERNE BLVD	90004	4	138B189   153	5523020008	R1-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Expired	02/08/2016 12:00:00 AM	ADDRESS	34.07777	-118.32469	PV1, Install 7 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformered inverter. Fronius IG 5100 NEG. 28 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12501	13041-20000-27584	14502 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.23524	-118.4483	T24 FOR YOGURTLAND. THIS IS NOT A FIRST TIME TENANT PER APPLICANT DESCRIPTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12502	17041-10000-19840	968 N SOMERA ROAD	90077	5	144B149   325	4369033014	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.0879	-118.45678	PC for one new Tesla Powerwall2 connected to existing load center and PV systen. PV permit for existing solar system under 17041-90000-16233.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12503	10041-20000-09578	6109 N DE SOTO AVE	91367	3	177B105    43	2149005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	ADDRESS	34.18151	-118.5908	Plan check T-24 Energy for general lighting in corridor on 2nd floor. All emergency lighting are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12504	16041-20000-11650	5337 E ABBOTT PL	90042	1	153A227   308	5469022033	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.11211	-118.20031	PV1.  Install 3.0 kW AC roof-mounted PV system.  (10) modules with 3kW rated central inverter.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12505	14041-10000-13198	9165 N SHARP AVE	91331	6	198B161   505	2628004022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Expired	07/12/2016 12:00:00 AM	ADDRESS	34.23576	-118.41383	PV1, INSTALL 4.08 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER AND TRANFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12506	09041-10001-24228	7551 W SUNSET BLVD	90046	4	147B177   981	5550009023	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	04/15/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	34.09821	-118.35418	Plan check T-24 energy (general/emergency lighting) for TI of beauty salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12507	13041-20000-01827	11430 W EMELITA ST PV	91601	4	174B169   169	2338014011	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			01/23/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	PIN	34.17643183	-118.3801515	PV for apartment. solar edge with power boxes. Transformerless. 3.84kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12508	12041-10000-05124	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.04842	-118.33486	Plan check for T24 Energy. Addition of lighting for power shelves. Existing permit #11041-10000-27220	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12509	18041-10000-09032	317 N EUBANK AVE #1	90744	15	030B209  1063	7424003036	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	33.77379	-118.25433	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12510	15041-10001-21820	1337 S HOPE ST	90015	14	126A207   202	5134011024	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.03855	-118.2665	"01/26/2017. Changes to an approved set of plans. Changes removed LCP lighting panel, and demand respond. Additional panel ""PC"". Changes has been clouded."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12511	13041-20000-24975	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.22149	-118.43179	Plan check for energy and power. Replacement of existing heating and hot water boiling system. Addition of pumps and 200A MCC. Medical Office Building. Kaiser Permanente North II Medical Office.COMMERCIAL BUILDING ALTER/REPAIR: REPLACEMENT IF THE (E) HEATING HOT WATER BOILER SYSTEM AO PIPING, ONE ACCESSABLE DRINKING FOUNTAIN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12512	15041-20000-36195	1463 W 3RD ST	90026	13	133-5A207 247	5153027004	C2-1	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Expired	11/27/2017 12:00:00 AM	PIN	34.05935752	-118.26357841	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12513	19041-20000-15595	2927 1/2 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Closed	11/05/2021 12:00:00 AM	ADDRESS	34.10426	-118.24385	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12514	18041-20002-17418	11015 N LOUISE AVE	91344	12	210B133   673	2696002009	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.27014	-118.51122	Changes to an approved set of plan. Changes include relocate equipments. Changes has been clouded. Plan check onlyFees $0.00 Due to California Senate Bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12515	17041-20001-13854	19126 W PALA MESA PL	91326	12	213B121   700	2822035010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.27785	-118.55051	expeditepv1install roof mounted pv system sized 14.3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12516	13041-10000-08473	432 E TEMPLE ST	90012	14	130-5A215 298	5173008906	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/02/2013 12:00:00 AM	ADDRESS	34.05043	-118.23692	PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR TWO BATHROOMS. NO EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12517	18041-20000-24411	2137 W GRANDEUR DR	90732	15	012B189   195	7562024011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	33.72835	-118.32146	install battery back up only, to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12518	10041-10001-01159	15825 W ROXFORD ST	91342	7	222B141    96	2604002037	M1-1, P-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM			PC Approved	03/01/2010 12:00:00 AM	ADDRESS	34.30457	-118.47839	REVISION TO PREVIOUSLY APPROVED PLAN 10041-10000-01159. CHANGE WAS TO RELOCATE DIFFERENT LOCATION OF THE 50KW GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12519	12041-10002-04692	4400 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.09662	-118.28529	SUPPLEMENTAL APPLICATION FOR REVISION TO THE APPROVED PLAN. ALL THE CHANGES ARE SHOWN BY DELTA 7. TI OFFICE RENOVATION. 40,000 SQ FT. SINGLE STORY. T24 EMERGENCY LIGHTING, POWER INCLUDED. FIRE ALARM VARIANCE ISSUED.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12520	11041-10000-20378	3333 S MANNING AVE	90064	5	123B161   812	4316032011	R3-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	09/23/2011 12:00:00 AM		Issued	09/23/2011 12:00:00 AM	ADDRESS	34.03112	-118.40638	new fire alarm for 2 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12521	12041-10000-19242	1688 W MORSE DR	90732	15	012B189    60	7562012004	R1-1XL	Harbor	San Pedro	Coastal San Pedro, Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	33.72883	-118.31371	NEW 6.4KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12522	12041-20000-12388	7370 W SUNSET BLVD	90046	4	147B181   654	5550021001	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.09785	-118.35128	Revised plan which was previously approved on application numbers 11041-20000-23687 and 12041-20000-23687.  The revisions covered the installtion of a new elevator and new panel boards, and the installation of 100 circuits.  The WHP-1 units were permitted as devices on application 12041-20000-05047.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12523	15041-20000-18582	5742 N WISH AVE	91316	6	174B133   212	2255022019	R1-1-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.17552	-118.50576	Plan check for PV roof mounted system. System size: 7.6kW  and 34 modules and 1 inverter(7.6kW). Standard Plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12524	19041-10000-32509	2454 W PICO BLVD	90006	1	129B197  1090	5056001059	C2-2D-CPIO	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	34.04708	-118.29064	Energy plan check for an existing restaurant T.I located in a single story building. Scope includes new lighting and equipment with a total lighting area of 1,279-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12525	16041-10001-02117	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Issued	10/12/2016 12:00:00 AM	ADDRESS	34.0965	-118.30717	Changes to approved set.  Addition of double pull section on supply side of switchboard.  New conductors feeding two switchboards.  Fault current and voltage drop updated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12526	10041-20000-18350	2580 N GLENDALE BLVD	90039	4	150A209   185	5438016002	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM			PC Approved	09/16/2010 12:00:00 AM	ADDRESS	34.10497	-118.25927	lost plans plan check only existing permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12527	14041-20002-02840	20601 W TIARA ST	91367	3	177B109   177	2151001005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.17722	-118.58179	Modification to approved set.  Inverter input circuit wire gauge increase and (2) additional modules on rooftop making 26 modules total.  $0 submittal and inspection fee is due to CA State Senate Bill SB-1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12528	19041-10000-48936	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	07/24/2020 12:00:00 AM		Permit Finaled	02/15/2022 12:00:00 AM	ADDRESS	34.07125	-118.35662	FULL PC FOR A NEW CONTRUCTION (RETAIL), SCOPE OF WORK INCLUDES A NEW DISTRIBUION PANEL (1200A) THAT IS BEING FED BY AN EXISITNG 2000A SWITCHBOARD. THE NEW DISTRIBUTION BOARD FEEDS TWO NEW TRANSFORMERS THAT FEEDS  NEW HOUSE PANELS AND OTHER ASSOCITED ELECTRICAL EQUIPMENT.  TOTAL AFFECTED AREA IS 17,901 SQFT. PER BUILDING ((NEW RETAIL / BUILDING 2-STORY W/ MEZZANINE19010-10000-05310))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12529	16041-10000-30260	157 S FAIRFAX AVE	90036	5	138B177   716	5511025012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.07256	-118.36158	PC for energy only. TI on 1st floor of a 2 story existing office/wholesale building.  Installing new lighting and power. Total sqft = 1472	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12530	19041-20000-36714	2837 S BRONSON AVE	90018	10	123B185  1166	5051008008	RD2-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.02997	-118.33397	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 17.48KW DC/15.71 KW AC. SCOPE OF WORK CONSISTS OF (46) PV MODULES WITH POWER OPTIMIZERS, A PV LOAD PANEL, AND (2) 7.7KW INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12531	14041-20001-06950	10180 N STONEHURST AVE	91040	7	204B173   165	2528018008	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	PIN	34.25541267	-118.37332746	PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12532	14041-10000-32916	601 W 8TH ST	90731	15	015B197   695	7454005027	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	33.73684	-118.29031	Renovation of (N) conference room and break room in (E) single-story commercial office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12533	17041-20000-13840	22950 W VANOWEN ST C	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.19343	-118.62746	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR AT&T DEALER STORE. SQFT 1725BUILDING PERMIT # 17016-20000-00696	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12534	19041-20000-40558	888 S FIGUEROA ST 940	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.0465	-118.26225	T.I. TO (E) OFFICE IN A HIGH-RISE BUILDING P.C FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12535	19041-10000-02667	6224 S FIGUEROA ST	90003	9	105B201  1037	6004038049	C2-1VL	South Los Angeles	South Los Angeles	Voices		2371.02	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.98261	-118.28245	New Fire Alarm System in the Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12536	13041-10000-14843	1701 E CESAR E CHAVEZ AVE 5TH FLR-SUITE 560	90033	14	130-5A221 204	5174007047	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	08/01/2013 12:00:00 AM	ADDRESS	34.05126	-118.2173	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ONLY. HEALT CARE FACILITY. NO MEDICAL EQUIPMENT IS INSTALLED. RECEPTACLES WILL BE INSTALLED IN PATIENT CARE AREAS IN COMPLIANCE WITH ARTICLE 517. REMINDER: TITLE 24 PART 6 ENERGY PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12537	10041-10002-11371	14309 W BURBANK BLVD 101-105	91401	4	174B153   754	2245010051	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Apartment			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.1723	-118.44467	Revisions to approved set of plans- voltage of service is 120/240V 3ph 4w with ISC 30KA ( WAS 35KA AT 120/208v) ; CIRCUIT BREAKERS TO UNIT PANELBOARDS CHANGED TO 100A;SOME FEEDERS CHANGED FROM al TO cu;20hp split to two 7.5hp units. Single line diagram has all changes clouded and identified as Delta 1 changes.Plan check power and energy for new for 8-unit apartment building with 2000A service.    <<<<<<<<Auto car lift on seperate application 10041-10001-11371>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12538	18041-20000-10273	4020 S LINCOLN BLVD Space D	90292	11	108B149  1249	4230002013	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	33.99001	-118.44704	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,148 sq. ft.Note: Building permit has been issued under 17016-10000-31123. Electrical permit fees have been under 18041-10000-06629.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12539	17041-10001-19132	2423 E 1ST ST	90033	14	127-5A223 177	5180002013	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.04348	-118.20886	PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, CHANGES INCLUDE REVISING LOADS, AND REVISING FEEDER LENGTHS, FAULT CURRENT HAS BEEN CHEKED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12540	13041-20001-31716	18131 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	34.16596	-118.52824	[1/15/15 CHANGES TO APPROVED SET OF PLANS. PLANCHECK ONLY. CHANGING ALL THE FEEDERS FROM COPPER TO ALUMINIUM]]]]]NEWSHELL AND CORE FOR A 4 STORY MEDICAL BUILDING.  BUILDING HAS A 5000A SERVICE AND A 4000A SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12541	19041-10000-47548	9190 N TELFAIR AVE	91352	6	198B165   418	2631002041	(T)(Q)R3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM	09/07/2021 12:00:00 AM		Permit Finaled	03/28/2024 12:00:00 AM	ADDRESS	34.23639	-118.39659	Full plan check for power and energy, service size 1200A, 120/208, 3Ph, 4 wire. Area of scope 11,866SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12542	15041-10000-02735	1901 W 6TH ST	90057	1	133-5A205 285	5154026001	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.05872	-118.27264	New fire alarm system including (1) fire alarm panel,  (1) annunciator, (3) power supplies & (182) devices  in a new contruction building with (53)units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12543	14041-10000-22011	9465 N NAGLE AVE	91331	6	198B153   268	2642010034	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.24167	-118.43862	Installation of roof mounted solar PV array.  Total system size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12544	15041-10001-17818	8631 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM			PC Approved	03/22/2016 12:00:00 AM	ADDRESS	34.07373	-118.38036	CHANGES MADE IN THE FIEL- ADDING A FEW FA DEVICEAS-BUIT SET OF PLANSNEW FIRE ALARM SYSTEM  FOR CEDAR - SINAI OFFICE TOWER. CORE AND SHELL .TWO BUILDING 8631 AND 8635 3RD ST CONNECTED WITH  BRIDGE. 1060 FA DEVICES, 7 CONTROL APNEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12545	19041-20000-03747	3745 S CARDIFF AVE	90034	5	120B165   622	4313016027	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			01/31/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	04/12/2022 12:00:00 AM	ADDRESS	34.02592	-118.39703	New 74 unit apartment building with 2000A 208Y/120V service.  Plan check for power and energy.Building permit application under 16010-10000-05912.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12546	18041-20001-19629	8201 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.21793	-118.6063	10/29/2018changes to an approved set of plans.  changes noted delta 6.  changes to relocate existing plugs and power equipment.  this is plan check only.  ((((PLAN CECK FOR POWER AND ENERGY FOR - New supermarket in an existing commercial shell space.  (E) distribution with new subpanels. SCOPE INCLUDES CONNECTING TO EXISTING SERVICE RATED AT 1600A 277/480. TOTAL NEW CONNECTED LOAD = 1400A, TOTAL AFFECTED AREA = 61607 SF Building permit under 18016-10000-16484.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12547	19041-10000-14850	951 S CROCKER ST #3	90021	14	124-5A211 161	5132001100	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Issued	04/23/2019 12:00:00 AM	ADDRESS	34.03538	-118.25024	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12548	17041-20000-04325	4710 S HOOVER ST	90037	9	112-5A201 360	5018026026	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Issued	02/10/2017 12:00:00 AM	ADDRESS	34.0004	-118.28694	ti to an existing single story comnmercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 2450	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12549	14041-20000-07672	3401-3405 N GLENDALE BLVD	90039	13	156B209   343	5435006006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.12023	-118.25882	PC FOR SERVICE CONSOLIDATION. EXISTING BUILDINGS TO REMAIN. NEW SERVICE AND REPLACE EXISTING PANELS PER NEW SERIES RATING. NEW 600A 240 3PHASE 4W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12550	16041-10000-25923	1149 S HILL ST 600 NE	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.03926	-118.26099	PC FOR Title 24, ENERGY ONLY. 1162SQFT 6TH FLOOR OFFICE SUITE 600 NORTH EAST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12551	18041-20000-35137	12506 W SANFORD ST	90066	11	105B161   667	4221012028	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	33.98409	-118.41688	Plan check for PV roof mounted system, system size: 14.46kW DC with 49 modules and 2 inverters(6.0kW) connected to MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12552	14041-20000-27158	523 W 6TH ST 4th Floor	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM			PC Approved	10/01/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	TI to (E) corridor in existing commercial highrise office building.  Plan check for Title 24 Part 6 2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12553	14041-10000-19640	3131 S HOOVER ST	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			07/22/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Closed	10/19/2017 12:00:00 AM	ADDRESS	34.02611	-118.28472	Installation of temporary power for construction of new student housing building. All equipment covered by this permit is temporary, therefore shall be removed after construction. Inspector to verify termination of large size conductors to ocpd.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12554	14041-20000-27590	1647 W TEMPLE ST 1-49	90026	13	136-5A207 119	5159023017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Apartment			10/06/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.06861	-118.26247	PV2.  Install 95.1 kW roof-mounted, utility-interactive PV system.FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12555	19041-10000-25621	11100 W SANTA MONICA BLVD 11th Floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	P.C FOR TITLE 24 TENANT IMPROVEMENT IN (E) OFFICE. TOTAL EFFECTED AREA 4127 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12556	16041-10001-29668	837 N NORTH SPRING ST #104	90012	1	135A215   307	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	ADDRESS	34.06303	-118.23651	10/03/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include replacing/adding lighting fixtures. Note: Permit is paid under PCIS#16041-10000-29668 ((((((INTERIOR TI TO SECOND FLOOR AND PART OF FIRST FOR OFFICEES. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12557	19041-10000-41423	718 S HILL ST	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	04/03/2024 12:00:00 AM	ADDRESS	34.04527	-118.25477	Power plan check for a new 2000-Amp service supplying an existing building. Scope includes new panels and generator. all fault curent calculation shall be recalcualted due to the new fault current from utility service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12558	14041-20000-17550	16633 W VENTURA BLVD	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.15823	-118.49571	TI to common areas in (E) commercial highrise building on floors 5 thru 13.    Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12559	19041-20000-23831	955 S FEDORA ST 1-60	90006	10	132B197  1168	5078003004	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.10	Electrical	Electrical	Apartment			06/20/2019 12:00:00 AM	09/01/2020 12:00:00 AM		Permit Finaled	04/24/2023 12:00:00 AM	ADDRESS	34.05401	-118.29802	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12560	17041-10001-30071	9717 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Info Complete	09/07/2017 12:00:00 AM	PIN	34.24624257	-118.53668453	PC FOR T24 ENERGY ONLY. REVISED PLAN TO SHOW NEW PANEL. CHECKING FOR ELC DOCUMENTS AND VOLTAGE DROP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12561	11041-10000-12414	1545 W WILSHIRE BLVD 1st fl	90017	1	132A205   208	5142027025	CW	Central	Westlake			2091.02	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	06/05/2012 12:00:00 AM	ADDRESS	34.05543	-118.26977	new panelboard and circuits in renovating offices on the 1st flplan check is for title24 and 1 ea emergency ckt ; permit fee is in Inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12562	11041-10003-04593	6401 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.18624	-118.59778	PLAN CHECK TO REVISION DELTA 11 TO APPROVED PLANS. UPGRADE 175A OCPD TO PANEL JB, ADD WASHER, DRYER, RENAME AV PANEL P4 AND ADD ADDITIONAL BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12563	19041-10000-04615	1966 N VERMONT AVE	90027	4	150B197   531	5590014108	R3-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.10732	-118.29156	Plan check for T24 only,  (E) Sikh Temple. Total area: 860 sq.ftB# 18014-10000-01768	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12564	14041-20000-10512	16769 W CHARMEL LANE	90272	11	132B121   176	4420027014	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.05898	-118.55018	Roof mounted PV system with Enphase model M215.  System size 5.94 KWdc. FEE is $0.00 due to State Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12565	15041-20000-22581	7606 COURAGE WAY	91405	6	186B145  1161			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20886358	-118.46419298	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12566	11041-10000-07189	10250 W SANTA MONICA BLVD #204	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	08/27/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12567	16041-20000-45613	12745 W ARROYO ST	91342	7	219B161    76	2525019064	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Info Complete	03/29/2017 12:00:00 AM	ADDRESS	34.29642	-118.40958	Phase 2 of new UPS distribution building.  (2) 4000 amp sevices and associated distribution equipment and load.  plan checkfor power and energy. building # 16010-10000-04890	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12568	17041-20000-31595	10219 N HAYVENHURST AVE	91343	12	204B137   447	2685016019	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.25626	-118.49378	PV1.  Install 5.2 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12569	18041-10000-31737	812 N EL ORO LANE	90272	11	129B121   293	4419012024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Re-Activate Permit	12/16/2019 12:00:00 AM	ADDRESS	34.05077	-118.54807	PC FOR ROOFMOUNTED 11.4KVA PV ON SFD SCOPE INCLUDES 3 CENTRAL INVERTER(SOLIVIA 3.8 TL) WITH 36 MODULES(SOLARCITY SC325).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12570	19041-30000-42200	6430 W SUNSET BLVD #1215	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.09782	-118.32979	Energy Plan check only. Area of scope 1,460SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12571	14041-20000-08606	575 N HANLEY AVE	90049	11	135B137    33	4494019027	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.06992	-118.48616	PV1.  Install 4.50 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.  18 modules: Canadian Solar CS6P-250P.  Microinverter: Enphase M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12572	18041-10000-19415	1067 N SWARTHMORE AVE 1-101	90272	11	129B125   837	4423016022	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.04834	-118.5249	"First time tenant improvement to existing retail space ""SERENA & LILY"" within Pacific Palisade Village. Full plan check for power and energy. New lighting and circuits, Total sq. ft. 2496"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12573	15041-10000-12001	100 WORLD WAY TERM 5	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	at lax, installation of illuminated  numeral signs to identify the terminalsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12574	13041-20000-19121	6954 N HALBRENT AVE	91405	6	183B145   406	2220021002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Expired	08/13/2015 12:00:00 AM	ADDRESS	34.1973	-118.46452	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING 27 MODULES AND CENTRAL INVERTER. TRANSFORERMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12575	17041-10000-29088	1518 N ALEXANDRIA AVE	90027	13	147B197   631	5543006010	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.0988	-118.29818	NEW FA SYSTEM FOR SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12576	18041-20000-12714	563 E COLEMAN AVE	90042	14	148-5A231  51	5301012030	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.10259	-118.18382	Plan check for Battery backup system Tesla PowerWall 2.0 connected to existing PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12577	18041-20000-04479	7595 W 80TH ST	90045	11	099B157   598	4114036018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	33.96386	-118.43081	pv1install roof mounted pv system sized 10.8kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12578	19041-10000-15061	5670 W WILSHIRE BLVD 21ST FLOOR-CORRIDOR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	PC for energy only. scope include Ltg in the corridor and restrooms. scope of work area 620SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12579	14041-20000-29785	12554 N AMBOY AVE	91342	7	219B145   220	2604041011	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.29878	-118.47072	PV1. ROOFMOUNTED SYSTEM. SYSTEM SIZE: 5KW .(20) ENPHASE M250(20) LG 300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12580	16041-10000-10015	1245 W WILSHIRE BLVD # 780	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	FULL PC FOR POWER AND ENERGY. TI FOR AN (E) MEDICAL OFFICE FOR SUITE 780. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR EXAM ROOMS (GENERAL CARE AREA/ NON INVASIVE PROCEDURES) AND OFFICE SPACE. TOTAL AFFECTED AREA IS 1501 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12581	17041-10000-30526	241 N LAKE ST	90026	13	136-5A205 103	5157018062	R4-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.06936	-118.27013	5 story 41 units apartment bldg new fire alarm	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12582	17041-20000-05544	17836 W CATHEDRAL PL	91316	5	165B129   207	2184029008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	04/29/2017 12:00:00 AM	ADDRESS	34.14922	-118.52188	Plan check for installation of a solar pv system, roof-mounted on SFD. Interconnect with 400A MSP.Existing 15kW pv system on SFD. New system is 3kW ungrounded. (10) 315W pv modules. Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12583	13041-10000-17673	890 N TOYOPA DR 4-10-4-12	90272	11	126B129    71	4411001013	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.04436	-118.52418	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING FOR A TENANT IMPROVEMENT. CLASSROOMS AND OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12584	14041-10001-12479	5744 S BRYNHURST AVE	90043	8	108B185   821	5006003016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	33.98954	-118.33317	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12585	18041-20002-03149	5367 N WINNETKA AVE	91364	3	171B113    69	2166006007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	Yes	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Issued	02/26/2018 12:00:00 AM	ADDRESS	34.16778	-118.5711	2/26/2018changes to an approved set of plans.  changes noted delta 1.  changes to include new 200 amp fusible disconnect.(((Plan check for the addition of (3) Tesla PowerWalls onto an existing PV system.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12586	11041-10000-06923	3500 N NORTH BROADWAY	90031	1	138A225    40	5208031032	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			PC Info Complete	04/29/2011 12:00:00 AM	ADDRESS	34.07365	-118.20366	Title 24 in an existing restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12587	15041-20001-20535	11906 W SARAH ST	91607	2	168B169   897	2364004014	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.15388	-118.39241	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Plan check is for the addition of 8.2 kWac system onto an existing 5 kWac system. Total system size is 13.2 kWac. System consists of (1) inverter, (37) modules, (1) combiner box and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12588	13041-10000-31547	135 E 35TH ST	90011	9	118-5A205 276	5120006008	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.01737	-118.27183	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12589	15041-20000-17259	7512 N GAVIOTA AVE	91406	6	186B141   229	2206017008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Expired	06/29/2017 12:00:00 AM	ADDRESS	34.20705	-118.48132	PV1. Standard plan. Install roof mounted solar system sized 3.6 KW. Interconnected with main service panel.(17) KU 260 Modules(1) PVI 3.6 TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12590	17041-10002-04624	20165 W RINALDI ST BLDG S1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.27527	-118.57297	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  25, 26, & 28. CHANGES INCLUDE RELOCATING SITE/LANDSCAPE LIGHTING, ADDING LANDSCAPE LIGHTING,  REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, AND REVISING PANEL SCHEDULES.NOTE: PERMIT HAS BEEN PULLED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12591	19041-10000-09655	8945 W EXPOSITION BLVD	90034	5	120B169    63	4312012041	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.02852	-118.39183	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12592	18041-20000-08999	19864 W LONGHORN DR	91311	12	207B113   338	2708031004	(T)(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.26777	-118.56645	pv1install roof mounted pv system sized 5.7kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12593	16041-10000-26865	8675 S FALMOUTH AVE	90293	11	096B153  1044	4118017***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.03	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Expired	09/12/2018 12:00:00 AM	ADDRESS	33.95542	-118.43539	PC FOR A FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING THE EXISTING FA PANEL, ANNUNCIATOR, AND 1 SMOKE DETECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12594	19041-10000-51409	14333 W AETNA ST	91401	6	177A151    78	2240008903	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	02/27/2020 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	34.18023	-118.44551	PC FOR POWER ONLY. SCOPE INCLUDES A NEW 400A 480/277V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, NEW LIGHTS FOR A HOMELESS SHELTER.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12595	09041-10003-24166	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/26/2010 12:00:00 AM		Permit Finaled	05/03/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. /   baggage screening area addition to existing terminal 5 at L.A.X.((((((((((( Revision to previously approved set of plans. all changes noted on the plans.))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12596	12041-10000-22824	1925 S CENTURY PARK EAST	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM			PC Approved	09/25/2012 12:00:00 AM	ADDRESS	34.06066	-118.41426	REMODEL OFFICE SPACE-NEW LUMINAIRES,CONFERENCE ROOM AND OFFICE IN SUITE 2020PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12597	19041-20000-53747	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Info Complete	12/30/2019 12:00:00 AM	ADDRESS	34.14441	-118.39252	Plan check for Title 24 Energy only existing space new lighting in 2nd floor. Total area: 4588 sq ft. B#19016-20000-34969	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12598	18041-10001-33636	9361 N WHITE OAK AVE	91325	12	198B129   154	2766002003	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM			Reviewed by Supervisor	09/11/2018 12:00:00 AM	ADDRESS	34.24067	-118.52024	**EXPEDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV FOR SFD WITH ESS. SCOPE INCLUDES 30 MODULES WITH MICROINVERTERS AND  ENPHASE BATTERY. TOTAL PV SYSTEM SIZE 7.2KW AC/  9.2 KW DC4 NEW AC COUPLED ENPHASE BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12599	16041-10003-25050	1426 S HAYWORTH AVE	90035	10	129B173   575	5068017016	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			09/07/2018 12:00:00 AM			PC Approved	12/31/2018 12:00:00 AM	ADDRESS	34.05069	-118.36762	PLAN CHECK FOR A LOST SET OF PLANS. PLAN CHECK FOR POWER AND ENERGY.  NEW 3-STORY, 8-UNIT APARTMENT BUILDING, OVER ONE LEVEL SUBTERANEAN PARKING. 800 A  3PH-4W SERVICE. TOTAL AREA 7,894 SQ.FT. LOCATED ON METHANE ZONE.B# 14010-10000-04170NOTE: PERMIT IS PULLED THE ORIGINAL APPLICATION PCIS#16041-10000-25050	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12600	19041-10000-30343	515 S FIGUEROA ST 17th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	PC for T24 only in an exisitng highrise, scope of work is TI in the 17th floor. Scope of work includes new lighting, controls, new circuits, and new outlets on existing branch circuits. Total affected area is 7608 sqft. B#19016-10000-20251	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12601	13041-20000-03501	707 W WILSHIRE BLVD FLRS 52,-53,54	90017	9	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.04893	-118.2572	Change to lighting, new loads on three floors, existing office building.  Load is greater than 400 amps.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12602	12041-10000-23584	2423 W HILL DR	90041	14	163-5A221  39	5682001036	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	04/02/2013 12:00:00 AM	ADDRESS	34.14393	-118.21874	FOR A SFD, ROOF-MOUNTED 4.16KW PHOTOVOLTAIC SYSTEM USING MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12603	18041-20001-32850	20101 W WELLS DR	91364	3	171B113   408	2166009003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Issued	10/09/2018 12:00:00 AM	ADDRESS	34.16259	-118.57055	10/9/2018changes to an approved set of plans.  changes to (52) modules and inverter upsize to 7.6KW AC new load.  ((((Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWdc/13.99 kWac-CEC and consists of (2) inverters, (48) modules, and (1) load center.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12604	18041-10000-40573	1400 W 190TH ST C	90501	15	060B193   447	7351002027	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Closed	03/12/2019 12:00:00 AM	ADDRESS	33.85811	-118.30226	PC FOR ENERGY ONLY FOR RESTAURANT TI CHANGE OF USE IN SINGLE STORY STRIP MALL. SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 1000 SQ.FT B#18016-10000-26462	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12605	12041-20000-04610	127 S SAN VICENTE BLVD Bulletin-133  CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM			PC Approved	02/29/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin-133 CS REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12606	12041-10000-02929	6902 N ALDEA AVE	91406	12	183B133   758	2230002006	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.19572	-118.50824	ROOF MOUNTED PV SYSTEM,5.28KW SYSTEM FOR A SINGLE FAMILY RESIDENCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12607	15041-20001-17225	14857 W BESSEMER ST #5	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.18089	-118.45716	07-27-2015 Plan check for lost original set of plans, Title 24 only[[[[Plan check for Title 24 only for retail T.I. Total area: 2,400 SF.]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12608	12041-20002-08340	14630 W PLUMMER ST	91402	7	198B149    69	2650026900	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM			PC Approved	01/23/2015 12:00:00 AM	ADDRESS	34.2424	-118.45147	REVISIONS TO AN APPROVED SET OF PLANS.  RELOCATE OF SWITCHGEAR NOTED ON PLANS BY DELTA 7.  PLAN CHECK POWER AND ENERGY FOR NEW TWO STORY LAFD FIRE STATION. NEW 800 A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12609	15041-10000-40656	1158 S CALZONA ST	90023	14	118-5A227 176	5191004025	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.01939	-118.1962	PV1 INSTALL 3.72 KW DC SOLAR ARAY ON A SINGLE FAMILY HOUSE, (12) MODULES: CANADIAN SOLAR (10 INVERTER: SMA SB 3000-TL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12610	19041-20000-21791	19033 W BRASILIA DR	91326	12	216B121   289	2872005017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.28812	-118.54663	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 3.2 kWdc/3.8 kWac and consists of (1) inverter, (10) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12611	16041-10002-24674	16717 W ALGINET PL	91436	5	159B137   215	2287011032	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.13379	-118.4967	Changes to an approved set of plans. All changes are clouded under delta 5. changes include replacing subpanel with an AC combiner box, and changing conductor size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12612	15041-20000-39351	2710 E 4TH ST	90033	14	126A225   258	5185008003	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.03862	-118.20767	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12613	15041-10001-26641	9912 W COVELLO ST	91504	2	186B181   309	2405019023	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.05	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.2075	-118.34696	EXPEDDITED RSES PLAN C HECK PER  APPLICANT REQUEST.<<PV1, INSTALL NEW 12.985 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(49) MODULES: KYOCERA KU2606XPA(2) ABB PVI-6000-OUTD-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12614	12041-20000-05262	11440 W SAN VICENTE BLVD	90049	11	129B145   238	4265003039	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.05178	-118.46028	energy plan checl 1st floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12615	11041-10002-15949	3470 S MCCLINTOCK AVE CINEMATIC-ARTS	90089	9	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM			PC Approved	10/04/2012 12:00:00 AM	ADDRESS	34.0236	-118.28768	Lighting modifications to a previously approved set of drawings.  PLAN CHECK ONLY for Energy.  No modification to emergency lighting.           <<<NEW 3-STORY WITH BASEMENT ACADEMIC BUILDING.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12616	12041-10000-16044	1945 E 16TH ST	90021	14	120A215   185	5167019034	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	PIN	34.02205893	-118.23797328	Plan check for energy and emergency lighting. Commercial low-rise office space. 7492 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12617	19041-10000-26392	9027 N CANOGA AVE STE B	91304	3	195B105    39	2779018039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.23429	-118.59779	Remove HID fixtures and replace with new LED fixtures (Indoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12618	13041-10000-28151	303 S PACIFIC AVE 1-49	90731	15	018B197  1575	7451018027	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Apartment			10/09/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	33.7413	-118.28819	INSTALLING FIRE ALARM SYSTEM IN A NEW 4-STORY 49 UNIT APARTMENT BUILDING. TOTAL SQUARE FOOTAGE IS 93500, SPRINKLED SYSTEM, WITH 150 DEVICES AND 2 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12619	14041-10001-07702	6290 W SUNSET BLVD UNIT-C	90028	13	147A189   227	5546025029	(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.09777	-118.32646	CHANGES TO APPROVED: LIGHTING fixture types, wattage, and quantity revised. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12620	11041-10002-22185	852 S BROADWAY	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	ADDRESS	34.04246	-118.2557	REVISED LIGHTING PLAN TO SHOW THAT TRACK LIGHTING HAS BEEN INSTALLEDPLAN CHK IS FOR TITLE 24 ONLYChange of use from retail to restaurant in a high-rise building.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12621	16041-10001-17318	4408 W JEFFERSON BLVD	90016	10	120B181   778	5046009002	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.02541	-118.34433	Plan check for T-24 only.  Change of use from warehouse to office. Additional load < 400A. Affected area: 3,840 sq.ft.  Additional permit covered for this project was issued under 16041-30000-17318. ((B#14014-10000-05935))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12622	07041-10006-24502	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Apartment			02/21/2012 12:00:00 AM			PC Approved	02/21/2012 12:00:00 AM	ADDRESS	34.05562	-118.27458	Plan check revision Delta 14. Fire pump circuit conductors are 2-hour rated MC Cable with 1000AF overcurrent protection and service conductors in 2 hour rated room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12623	19041-10000-21401	13121 W ADDISON ST	91423	4	171B161  1020	2358008004	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.16133	-118.41867	(ePlan) New PV1 rooftop 12.6 kW DC / 10.4 kW AC system.  Install (36) AC Modules, two strings are located on separate (garage) structure and one string on the main house.  (1) 100A load center. system connect to (E) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12624	11041-20000-19437	6442 N PLATT AVE	91307	3	180B093   512	2036024053	(Q)C1-1VL, (Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL, C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM	09/15/2011 12:00:00 AM		Permit Finaled	10/07/2011 12:00:00 AM	ADDRESS	34.188	-118.64248	PLAN CHECK T24 ENERGY FOR TENANT IMPROVEMENT WEIGHT WATCHERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12625	10041-10000-16577	19630 S PACIFIC GATEWAY DR	90502	15	057B197    37	7351034073	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	10/08/2010 12:00:00 AM		Permit Finaled	12/02/2010 12:00:00 AM	ADDRESS	33.85299	-118.29513	Ti in an existing office. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12626	16041-20001-37736	252 S RAMPART BLVD	90057	13	136-5A203 304	5155025900	R4-1	Central	Westlake	Greater Echo Park Elysian	Yes	2086.20	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM	ADDRESS	34.067	-118.27813	Revision to an approved set , change under delta 9. change includes adding emergency circuits at the stairs and corridors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12627	18041-20000-02190	21150 W VENTURA BLVD	91364	3	171B105   186	2167002010	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.16706	-118.59444	Restaurant tenant improvement.  Design-build plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12628	16041-20000-01203	11559 W DONA TERESA DR	91604	2	159B169   478	2381004009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.1312	-118.38556	Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 9kW (3kW+6kW). (41) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12629	11041-10000-13125	2030 S WESTGATE AVE	90025	11	123B149   349	4262033021	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Info Complete	06/23/2011 12:00:00 AM	ADDRESS	34.03465	-118.45236	RECONNECT TWO 400A FEEDERS FROM AN EXISTING SWITCHBOARD & FEED THEM FROM A NEW SWITCHBOARD FOR SEPERATE METERING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12630	19041-10000-37490	647 S MATEO ST	90021	14	124-5A217 108	5164012025	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.03639	-118.23274	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12631	12041-20000-28878	2131 S BEVERLY GLEN BLVD	90025	5	129B157   395	4317012062	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			11/30/2012 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.05151	-118.42183	TWO STORY 6 UNIT APT OVER SUBTERRANIAN GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12632	19041-20000-02895	13359 N MISSION TIERRA WAY	91344	12	225B133    97	2601013040	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	ADDRESS	34.31264	-118.50167	pc for pv. adding 15 LG newon 3201C-G4 and 15-400w solaredge optimizer. 1 inverter solaredge 10000A-US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12633	17041-10000-37669	624 S GRAND AVE WATER-SYSTEM	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	Electrical distribution to support a new condenser water system. Two new 1MVA unit substations and two new 1200A mechanical distribution switchboards will be installed in an existing level 2 equipment room. New substations will be fed from and existing swbd HVL4 located on level 4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12634	17041-20001-06492	1540 W FRANCISCO ST	90501	15	057B193    29	7351021033	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	33.84927	-118.30492	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12635	15041-20000-39347	10556 W CANTARA ST	91352	2	192B177  1002	2407008029	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.21885	-118.36155	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (14) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12636	09041-20001-22879	9671 N SUNLAND BLVD	91040	7	201B177   261	2542018013	(Q)C1-1VL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM			PC Approved	10/26/2010 12:00:00 AM	ADDRESS	34.24723	-118.358	revise single line diagram to have 600 A board part of the 1200A switchboard	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12637	16041-10002-06474	300 S SANTA FE AVE SPACE B	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Expired	09/24/2018 12:00:00 AM	ADDRESS	34.04587	-118.23239	Changes to an approved set of plans. Changes include wiring on Emergency Lighings and Title 24 calculation additonal 2 branch circuits. (((((((PC FOR POWER AND ENERGY. 6 STORY BUILDING. 1ST TIME TENANT BOOKSTORE RETAIL IN SPACE B, GROUND LEVEL. TOTAL AREA 2289 SQ FT.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12638	11041-20000-19181	19666 W VENTURA BLVD	91356	3	174B117   352	2164014011	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.1724	-118.56189	7-Eleven t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12639	16041-20000-29042	10250 W CONSTELLATION BLVD 31st-32nd	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for the replacement of existing exit signs and installation of new exit signs on the 31st and 32nd floors of an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12640	15041-10000-00039	3498 E 14TH ST # B	90023	14	118-5A225 385	5190037010	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.01719	-118.20299	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3352 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12641	18041-20002-26393	3732 W CLAYTON AVE	90027	4	148-5A203 330	5430009015	R1-1	Central	Hollywood	Los Feliz	Yes	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM	ADDRESS	34.10052	-118.27558	10-25-2018 Changes to an approved set of plan, Changes include interconnection point to breaker 100A. Changes has been clouded as delta B. Plan check only. Fees $0 due to Califnornia Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12642	17041-10000-13873	1256 W 7TH ST	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM			PC Info Complete	07/03/2017 12:00:00 AM	ADDRESS	34.05216	-118.26774	PC FOR ENERGY ONLY. T.I. CHANGE OF USE FROM COCTAIL LOUNGE TO COFFEE SHOP AT THE MAIN LOBBY. NEW CONNECTED LOAD< 400 AMP. TOTAL AREA 1406 SQ FT.B # 17016-10000-08643	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12643	14041-10000-32461	370 E IMPERIAL HWY	90061	15	087A207   299	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	33.93089	-118.26698	Per�Senate�Bill�No.1222, Fee cap reached, thus fee is $0.PV2, INSTALL  15.68 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMERCIAL  BUILDING. INTERCONNECT WITH MAIN SERVICE PANEL. 6 STRINGS.(2) INVERTERS:  DELTA-SOLIVIA 7.6TL (56) MODULES: LDK SOLAR LDK-280P-24	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12644	17041-20000-03178	10101 N LARAMIE AVE	91311	12	204B113   475	2741010018	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Issued	01/31/2017 12:00:00 AM	ADDRESS	34.25396	-118.57342	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12645	16041-10000-16027	5656 N BELLINGHAM AVE	91607	2	174B165   511	2340025006	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	05/28/2016 12:00:00 AM	ADDRESS	34.17384	-118.39856	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP.   TOTAL SYSTEM SIZE IS  7.50KWdc / 7.125KWac. (25) AC MODULES- LG MONOX LG300A1C-B3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12646	17041-10000-37194	7350 N COLDWATER CANYON AVE	91605	2	186B161   539	2324005025	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.20412	-118.41361	REPLACING OUTDOOR AND INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12647	19041-10000-33848	17537 W SUNBURST ST	91325	12	195B129    28	2768024014	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.23466	-118.51715	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED SYSTEM CONSISTING 41 MODULES (Q-CELL 305), 41 OPTIMIZERS (SE P320) AND 1 INVERTERS(SE10000H-US) CONNECTED TO AN EXISTING 200A SERVICE. SYSTEM SIZE IS 12.51 KWdc AND 10KWac.MAIN BREAKER DERATE TO 175A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12648	13041-10001-22911	10523 N WHITE OAK AVE	91344	12	207B129   824	2733008004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM			Plans on Hold	08/29/2013 12:00:00 AM	ADDRESS	34.26206	-118.52004	EXPIDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR ARRAY. INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER, UNGROUNDED SYSTEM. SYSTEM SIZE: 10.78kW. 2 TPOWER ONE AURORA INVERTERS ( 6KW AND 3KW) .44 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12649	14041-20001-16376	4944 N HOOD DR	91364	3	171B113   537	2175020007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM			PC Approved	07/02/2014 12:00:00 AM	ADDRESS	34.16112	-118.56838	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.5 KW DC USING MICROINVERTERS ENPHASE M215. USING 39 MODULES. 8.3KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12650	18041-10000-15154	828 E G ST	90744	15	030B209   353	7424012014	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	33.77895	-118.25223	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12651	16041-20000-14352	9360 N PENFIELD AVE	91311	12	198B113    95	2761040017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.24095	-118.56948	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 14896.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12652	14041-20000-30434	4812 S 8TH AVE	90043	8	111B189   992	5014010003	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Expired	11/28/2016 12:00:00 AM	ADDRESS	33.99952	-118.32561	PV1 SFD. TOTAL SYSTEM SIZE 3.4KW AC USING 16 MODULES. USING MICROINVERTER ENPHASE M215. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12653	11041-10000-04296	11831 W WILSHIRE BLVD	90049	11	129B145   783	4265013038	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM			PC Approved	03/16/2011 12:00:00 AM	PIN	34.04781553	-118.46347877	TI TO AN EXISTING RESTAURANT.  T-24 PLAN CHECK ONLY.  2 LEVEL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12654	17041-20000-30290	14747 N SAN FERNANDO ROAD	91344	12	228B133    49	2601011015	A1-1-O, [T][Q]M3-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.32306	-118.5027	Plan check for power only. Project site is an existing landfill. Project scope is the replace of a 600-amp switchgear and feeder replacement for a manual transfer switch.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12655	13041-10000-26733	14614 W CHASE ST bldg b	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Info Complete	03/19/2014 12:00:00 AM	ADDRESS	34.22458	-118.45115	Core and shell for 1-story type V-B retail and restaurant.  11,349 sq ft.  BLDG B on submitted electrical plan set. Tenants to have their own plan check  and permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12656	17041-20000-43972	8241 N MELBA AVE	91304	12	192B093   469	2020021008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.21895	-118.63442	Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.5.2kW ungrounded pv system. (15) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12657	14041-10000-03526	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/07/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	PLANCHECK FOR TITLE 24 ENERGY ONLY. TENANT IMPROVEMENT FOR DODGER STADIUM. SMALL ADDITION TO AN EXISTING CONCESSION ON LEVEL 7 OF DODGERS STADIUM. 400 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12658	16041-20002-40989	1077 W 38TH ST	90037	8	117B197   508	5037015030	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.0174	-118.29395	12/6/2018changes to an approved set of plans.  changes noted E1 only.  changes to reflect field conditions.  this is plan check only.  ((((Plan check for power and energy. New 5 story building - 4-story 140 unit apartment (10 typ. units) over ground level parking garage and office space. (2) 2500A services and (1) 1000A service. T24 - indoor: 80,830sqft ; outdoor: 39,286sqft. NEW 5 STORY  PARTMENT BUILDING : 4 STORY TYPE V-A ,  140 UNITS ABOVE TYPE 1-A GROUND LEVEL PARKIN GARAGE & OFFICE ( 138 LOW INCOME RENTAL  UNITS & 2 MANAGER UNITS)   . THE PROJECT DOES NOT PROVIDE HOUSING ON BEHALF OF ANY PUBLIC INSTITUION BUT IS PARTIALLY PUBLICLY FUNDED AND SUBJECT TO UFAS REQUIREMENTS.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12659	11041-10000-06932	10112 W EMPYREAN WAY	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Apartment			04/07/2011 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	09/13/2011 12:00:00 AM	ADDRESS	34.05362	-118.40912	SWITCH GEAR UPGRADE DUE TO RUST.    REPLACING EXISTING SWITCHGEAR WITH NEW BUS AND BREAKERS.  ALL NEW BREAKERS SHALL MATCH OLD BREAKERS FOR SERIES RATING DOWN STREAM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12660	16041-10000-24750	2204 E ALCAZAR ST	90033	14	135A225    61	5202004042	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.06326	-118.20213	INSTALLATION OF  A NEW FIRE ALARM SYSTEM FOR A 6-STORY ABOVE GARAGE WITH 1 LEVEL BELOW GARAGE  COMMERCIAL BUILDING. 940 FA DEVICES, 1 FA PANELS,  (8) CONTROL PANELS, AND (1) COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12661	11041-20000-05319	6525 S NORMANDIE AVE 1-20	90047	8	105B193  1584	6015008017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.00	Electrical	Electrical	Apartment			03/17/2011 12:00:00 AM	03/17/2011 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	33.97994	-118.30044	fire alarm apartment building 4 stories 20 units	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12662	13041-20000-27280	25965 S NORMANDIE AVE 1,2,3 flr	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	Change to lighting in Lobbies only, no work in patient care areas of Kaiser Building.  1st, 2nd, and 3rd foor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12663	15041-20000-20882	1645 E 6TH ST	90023	14	126A219    57	5171007022	M1-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	34.03916	-118.22348		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12664	10041-20000-11941	12121 W WILSHIRE BLVD 1201	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	PIN	34.04391963	-118.46825257	office t.i.Energy.Emergency , fire/ life safety is existing to remain .permit is for power, lighting & phone plugs	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12665	15041-10000-24086	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	INSTALL NEW FIRE ALARM SYSTEM FOR A 14 STORY COMMERCIAL BUILDING. 677 DEVICES AND 2 FACPs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12666	12041-10005-16076	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM			PC Approved	07/24/2015 12:00:00 AM	ADDRESS	34.10158	-118.3062	CHANGES (DELTA G) TO PERMITTED SET OF PLANS FOR A THAI RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12667	16041-10000-08440	10385 S AVIATION BLVD	90045	11	087B165   145	4129028900	PF-1XL	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	33.94233	-118.37892	T-24, PC FOR OUTDOOR LIGHTING ON THE GUARDPOST AREA IN LAX. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL SQ. FT. 37,278.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12668	16041-20000-22323	405 N ALVARADO ST	90026	13	138A205   299	5157016029	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.07065	-118.26798	Re-Plancheck for t24 energy due to lost plans. (TI) to an (E) McDonalds. PC for T-24 only, total area: 1884 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12669	16041-20000-42863	11811 S TEALE ST	90230	11	105B165   298	4220006075	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	33.98545	-118.40128	Plan check for power and energy. Addition of 2-mezzanine levels inside existing office building. New lighting (incl. emergency) and receptacles. New 600A service. T24: indoor-10,729sqft; outdoor-5,254sqft.Note: Building permit has been issued under 16014-10000-05676.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12670	14041-10000-15758	4205 N KESTER AVE	91403	4	165A147   121	2276025009	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling	1	Dwelling - Single Family	06/12/2014 12:00:00 AM			Corrections Issued	06/12/2014 12:00:00 AM	ADDRESS	34.14717	-118.45952	PV1. ROOF MOUNTED SOLAR SYSTEM. TRANSFORMERLESS STANDARD PLAN WITH DC/DC CONVERTER. SYSTEM SIZE: 7600W AC.(30) TRINA SOLAR TSM-255(2) SOLAREDGE SE3800	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12671	10041-10000-06937	5376 E HUNTINGTON DR SOUTH	90032	14	144A237    50	5219033001	C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM	02/03/2012 12:00:00 AM		Issued	02/03/2012 12:00:00 AM	ADDRESS	34.09057	-118.16424	NEW GAS STATION. PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12672	17041-10002-44240	1848 S CRESCENT HEIGHTS BLVD	90035	10	126B173   437	5066009010	R1R3-RG	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Issued	12/12/2017 12:00:00 AM	ADDRESS	34.04277	-118.37477	Investigation fee for code enforcememt prior to PV permit is finalized.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12673	14041-10000-13556	6260 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Closed	08/22/2018 12:00:00 AM	ADDRESS	34.18497	-118.60418	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. 42 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12674	13041-10000-25056	14444 W TERRA BELLA ST UNIT 115	91402	6	198B149   633	2639010***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.23705	-118.44717	PV1. ROOF MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 2.695 KW. 11 MODULES. TRANSFORMERLESS INVERTER. 2 STORY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12675	14041-10000-21404	14402 W CALIFA ST #10	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12676	17041-20000-19168	360 E 2ND ST Suite 450	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	Plan check for energy only. TI to existing office on 4th floor of high rise office building (Suite 450).New lighting (incl. emergency) - 4,307sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12677	11041-10000-05231	100 S DOHENY DR	90048	5	138B169   365	4335008***	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	06/06/2011 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.07508	-118.38955	The existing emergency system is to be revised.  Install two coordinated ATS, and a new diesel genrator.  The existing gasoline generator shall become an optional standby generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12678	13041-10000-33053	13549 W RELIANCE ST	91331	6	192B157   122	2637009016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.22602	-118.42796	PV1 1.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(6)modules: {Yingli {YL250-29b}}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12679	16041-20000-34266	6852 W GREELEY ST	91042	7	202-5A201 430	2568019005	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.2486	-118.28121	Plan check for installation of pv system for SFD, roof-mounted. Interconnect with 200A MSP.1.44kW ungrounded system. (6) EnPhase M250 microinverters. (6) 275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12680	17041-20000-32398	6167-6171 N SEPULVEDA BLVD	91411	6	177B145   355	2242001015	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.18223	-118.46651	New single-story commercial building core and shell.  New 1200 A 120/208V service.  Tenant improvements under separate permits.Note: Building permit has been issued under 15010-10000-03148	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12681	10041-10003-22340	11827 W VENICE BLVD	90066	11	114B157   942	4234016001	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			Reviewed by Supervisor	10/23/2012 12:00:00 AM	ADDRESS	34.00775	-118.42664	REPLACEMENT OF THE LOST PLANS.  TI IN AN EXISTING CHURCH.  PLAN CHECK ONLY. EXISTING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12682	12041-20000-19506	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	T.I. to reception area in the basement level.  Install general/emergency lighting.  Plan check for energy only..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12683	16041-10000-25126	10384 N SEPULVEDA BLVD	91345	7	204B145   113	2649019009	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	11/24/2017 12:00:00 AM	ADDRESS	34.25921	-118.46706	FULL PC FOR FOR POWER AND ENERGY. FIRST TIME TENENT. TI BUILD OUT TO (E) CORE SHELL RESTAURANT SPACE WITH UNCOVERED OUTDOOR DINING. SCOPE INCLUDES NEW TWO NEW PANELS, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 2200 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12684	17041-20001-15687	19147 W STRATHERN ST	91335	3	189B121   166	2104003026	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.21574	-118.551	expeditepv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12685	19041-10000-33251	248 N LARCHMONT BLVD	90004	4	138B189   455	5515025001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	09/24/2021 12:00:00 AM	ADDRESS	34.07598	-118.32343	CHANGE OF USE FROM (E) TAKE-OUT RESTAURANT TO RETAIL. Installaing new ligts, T-24 only. Total Area: 716 Sqr Ft. Bulding Permit: 19016-20000-26445	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12686	13041-10001-23151	380 WORLD WAY 6C2-10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	(((((6/11/14- Changes made to approved set of plans - added UPS and relocation of circuits + revised title 24))))))FIRST TIME TENANT AT LAX TBIT. EMIRATES LOUNGE. 4 PANELS 1 75 KVA TRANSFORMER. PLAN CHECK FOR POWER AND TITLE 24 PART 6 ENERGY.***********************************************BUILDING APPLICATION NUMBER 13016-10000-17427.TI (EMERIT AIRLINE) LOUNGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12687	14041-20000-00201	1100 N BANNING BLVD	90744		033B209   587	7423020046							Electrical	Electrical	Apartment			01/03/2014 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	33.78533	-118.25813	emergency circuits in cooridoors	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12688	19041-20000-36685	22121 W ERWIN ST	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	06/02/2021 12:00:00 AM		Permit Finaled	06/21/2022 12:00:00 AM	ADDRESS	34.18299	-118.60947	Plan check for Pv roof mounted system, PV system size: 21.315KW DC, 18.9KW AC CEC with 49 PV Modules and 2 inverters( 9.0KW)Note: This is 12 Buildings on 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12689	19041-10000-34079	11040 W PICO BLVD	90064	5	126B153  1136	4256008021	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.03753	-118.43352	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12690	18041-20000-48366	2000 S AVENUE OF THE STARS 9TH FLOOR	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	TENANT IMPROVEMENT ON 9TH FLOOR OF COMMERCIAL HIGHRISE BUILDING.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12691	13041-10001-01810	9801 N SYLVIA AVE PV-1	91324	12	201B117   230	2762003016	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM			PC Info Complete	06/06/2013 12:00:00 AM	ADDRESS	34.2487	-118.55261	Modification to approved set 13041-20000-01810.  Solar power output downsized to accomodate owner's desire to not replace existing main service panel.  10.34 kW DC system size, roof-mounted solar array to be interconnected into existing main service panel.  {44 modules: Trina Solar TSM-240 PC/PA05} {Central inverter Fronius IG PLUS 7.5-1} Original Work Description: SOLAR SINGLE FAMILY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12692	19041-20000-17833	7419 N GREENBUSH AVE	91605	2	186B157   330	2328027056	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	03/16/2020 12:00:00 AM		Permit Finaled	04/15/2022 12:00:00 AM	ADDRESS	34.20517	-118.42644	TI REMODEL TO EXISTING COMMERCIAL BUILDING FROM WAREHOUSE TO HYDROPONIC AGRICULTURAL ENTERPRISE. PLAN CHECK FOR POWER AND ENERGY. NEW 3000A SERVICE. SCOPE OF WORK INCLUDES 3000A SERIVCE, 3000A PANEL BOARD, (12) 225A PANELSB#19016-20000-08709	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12693	18041-10000-02091	7356 N HAYVENHURST AVE	91406	6	186B137   238	2226001907	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20329	-118.49358	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12694	12041-10000-26130	1609 W COLORADO BLVD	90041	14	162A225    48	5669016017	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.13967	-118.20133	Change of use from office to dental office. EPC is for Power & Energy. Existing services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12695	15041-10000-16209	555 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.13776	-118.3584	TI-24 TO AN (E) COMMERCIAL BUILIDNG. EXISTING PANELS NEW LED LIGHTING. TOTAL SQ. FT. 1095	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12696	15041-20001-40829	1569 E 41ST PL	90011	9	114A213    86	5116012027	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			Reviewed by Supervisor	12/15/2015 12:00:00 AM	ADDRESS	34.00763	-118.2461	EXPEDITE FEE PER APPLICANTPV1, roof mounted solar system 3.8kW AC interconnect to (E)100A Service.(14) HANHWA Q CELL Q-PRO G4 260(1) SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12697	14041-10000-10563	16521 W NORDHOFF ST	91343	12	198B137   982	2676023022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.23585	-118.4924	pv on standard plans. micro inverter. 4 modules. 1 string and one story house.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12698	17041-10002-04619	20045 W RINALDI ST BLDG A5	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	04/23/2021 12:00:00 AM	ADDRESS	34.27564	-118.57092	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  17, 23, 25, 26, 28, & 29. CHANGES INCLUDE RELOCATING SITE/LANDSCAPE LIGHTING, ADDING LANDSCAPE LIGHTING,  REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, REVISING PANEL SCHEDULES, AND REVISING TITLE 24 CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12699	14041-10000-14548	12404 W VENICE BLVD	90066	11	111B153   231	4235013044	[T][Q]C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.00336	-118.43363	Title 24 only.  Total area = 1875 sq. ft.T.I. for existing building.  New starbucks with new fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12700	13041-10001-29573	6423 S ARLINGTON AVE	90043	8	105B189  1512	4007024014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	33.98126	-118.31881	Expedited RSES plan check per applicant request.((((PV1.  Install 5.75 kW DC roof-mounted solar array, interconnect with main service panel.  Inverter: Solaredge Se6000A-US.  23 modules: Hanwha Hsl60P6-Pb-4-250TW.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12701	15041-20000-12544	1355 E 21ST ST	90011	9	120A211   322	5119002006	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.02157	-118.25065	PV1 SFD TOTAL SYSTEM SIZE 3.4KW AC USING 16 MODULES. MICROINVERTER SYSTEM. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12702	10041-10000-22501	19600 W PLUMMER ST	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			11/18/2010 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.2426	-118.5602	New 4-stories mixed use building with 402 dwelling units  and retail/commercial areas.  A variance to to separate the electrical and fire alarm/lifesafety system plans and permits was submitted on March 10, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12703	13041-20000-01293	16333 W RAYMER ST	91406	6	189B137     7	2205029043		South Valley				1275.10	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.21814	-118.48811	New lighting in an existing commercial/retail space.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.   There is NO Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12704	15041-10001-28478	7247 N HAYVENHURST AVE UNIT-A1&A10	91406	6	186B137   305	2226001906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM			PC Approved	09/04/2015 12:00:00 AM	ADDRESS	34.20296	-118.49362	CHANGES TO AN APPROVE SET. CONDUCTOR CHANGED FROM STRANDED TO SOLID. (((NEW FIRE ALARM SYSTEM 135 DEVICES.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12705	17041-20000-22448	1055 W WILSHIRE BLVD Unit #5	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.05232	-118.2629	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is change of use from office to restaurant/tenant improvement. Total lighting area = 1,349 sq. ft.Note: Building application has been generated under 16016-20000-20573	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12706	14041-10001-27220	1351 N SPAULDING AVE	90046	4	147B177  1301	5551030010	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/14/2014 12:00:00 AM	ADDRESS	34.09578	-118.35721	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. <<INSTALL 8.925 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(35) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER(S): SOLAREDGE SE3800A-US-ZB-U & SE5000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12707	16041-10003-06619	7718 N HATTON PL	91335	12	189B129  1202	2120008017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.21092	-118.52318	CHANGES TO AN APPROVED SET OF PLANS NOTE CHANGES IN THE CLOUDED AREAS. CHANGES INCLUDES THE MODULE LAYOUT AND COUNT. (((PV1, ROOF MOUNTED SOLAR SYSTEM USING 2 CENTRAL INVERTERS. (34) MODULES,  (1) 6KW INVERTER AND (1) 3.8 KW INVERTER. TOTAL SIZE IS 11.1KW -DC)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12708	18041-20000-33986	2225 W SUNSET BLVD	90026	13	139-5A207  19	5402031026	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1956.00	Electrical	Electrical	Apartment			09/05/2018 12:00:00 AM			Reviewed by Supervisor	10/18/2018 12:00:00 AM	ADDRESS	34.0781	-118.26596	Plan check for power and energy for new 53 units multi-family and commercial mixed use(tower A, 4 story) building and 9 town homes. 5,000A  208/120V Service. Total area: 71,497 sq ft. B#18010-20000-03139	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12709	19041-20000-23755	12935 N SPROULE AVE	91342	7	222B153   241	2509017012	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.30532	-118.43556	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 5.1KW DC/4.6 WK AC. SCOPE OF WORK INCLUDES (17) LONGI PV MODULES AND A NINGBO GINLONG SOLIS-1P4.6K INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12710	17041-10000-43908	8500 W BEVERLY BLVD 602	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC for power and energy for first time restuarant tenant. Installing three new panels, 75kVA transformer, equipment and branch circuits. Total area is 1856sqft. B# 17016-10000-34180	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12711	14041-10000-33822	8318 1/2 W 3RD ST	90048	5	138B173   889	5511031035	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.07251	-118.37071	Energy plan check for a change of use from retail  to a restaurant. total 495 SQ feet. Permit pulled on application#:14041-90000-34010. Subject to additional inspection fees, inspector to verify.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12712	12041-10000-13905	500 S VIRGIL AVE	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	New Fire Alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12713	15041-10001-30177	2129 E JUDSON ST	90033	14	130-5A225  76	5175020006	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM			PC Approved	10/30/2015 12:00:00 AM	ADDRESS	34.05276	-118.20756	PC only, Permit under 15041-90000-30177Install roof top solar system 3kW AC(10)modules REC275TP(1) invertre: SE3000(240V)Standard plan is used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12714	18041-10000-27600	9380 N SAN FERNANDO ROAD	91352	6	198B169    71	2537024001	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.24027	-118.39384	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12715	15041-10000-04571	19875 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.23203	-118.56652	plan check for energy only. replacing metal halide lights with LED lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12716	13041-10001-27136	738 E BROOKS AVE	90291	11	111B145  1292	4239013027	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	33.99733	-118.46493	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12717	18041-20000-28973	2922 N BEVERLY GLEN CIR	90077	5	156B153    17	4382030065	RE15-1VLD-RPD-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.12759	-118.44343	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,887 sq. ft.Note: Building application has been generated under 18016-10000-16466	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12718	14041-20000-34584	12673 W WELBY WAY	91606	2	180B161   114	2325002024	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.1932	-118.40891	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system.14  270W pv modules across two strings (7+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12719	12041-20000-08337	23424 W KILTY PL	91307	3	183B093   162	2028019038	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21, 1344.22	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	05/31/2012 12:00:00 AM	ADDRESS	34.19967	-118.63849	pv system single family 4.9 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12720	16041-20000-07115	2002 W 41ST ST	90062	8	114B189   572	5022015031	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.0098	-118.31556	PV1.  Install 7 kW rooftop solar system w/ (28 modules).  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12721	15041-20000-42250	3764 S DUBLIN AVE	90008	10	117B189   546	5034013049	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	PIN	34.01823208	-118.32207663	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.12KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12722	18041-10000-33306	7245 N LAUREL CANYON BLVD	91605	2	186B165   260	2307022010	(T)(Q)M2-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.20265	-118.3968	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12723	13041-10001-33631	17417 W PARTHENIA ST	91325	12	195B129   420	2768015035	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.22873	-118.51399	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12724	18041-20000-10652	6200 N CANOGA AVE 325-375	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.1833	-118.59719	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12725	15041-20000-16515	9262 JUNEBERRY LANE	91343	7	198B145   458	2656021***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Expired	06/27/2017 12:00:00 AM	PIN	34.2394126	-118.46159735	pv1 sfd total system size 5kw ac using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12726	15041-10000-25715	1 S LMU DR #4900	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	PC FOR ENERGY, T-24 ONLY FOR A STARBUCKS LOCATION. SCOPE OF WORK INCLUDES THE ADDITION OF A FEW LIGHT FIXTURES. SQ FT = 1520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12727	16041-20008-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			06/19/2019 12:00:00 AM			PC Approved	06/19/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	PLAN CHECK ONLY, SUPPLEMENTAL FOR CHANGES TO APPROVED SET. SEPERATION OF INVERTER BATTERY FROM INVERTER, NEW CONDUCTORS, MINOR CHANGE TO FLOOR PLAN, AND A ADDITIONAL NOTE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12728	15041-10003-24845	2407-2419 E 1ST ST 1ST FL	90033	14	127-5A223 164	5180002016	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM			PC Approved	11/22/2017 12:00:00 AM	ADDRESS	34.04369	-118.20936	DELTA 9 CHANGES- AREA HOUSING GAS METERS  IS ENCLOSED(((((((((((((NEW 5 STORY MIX USED MULTI  FAMILY BLDG WITH 50 APARTMENTS UNITS AND BASEMENT PARKING. 30 TYPICAL-1 BEDROOM UNITS, 2 BEDROOMS - 4 TYPICAL , 16 TYPICAL- 3BEDROOMS APARTMENT UNITS. 2 COMMERCIAL UNITS IN THE FIRST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12729	19041-10000-48843	1825 N DOHENY DR	90069	4	150B169  1216	5561008025	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Expired	11/08/2023 12:00:00 AM	ADDRESS	34.10528	-118.38823	[EPLAN] CHANGES ON APPROVED SET ADDING 1 ESS (TESLA POWERWALL) AND 12 MODULES (HANWHA Q-CELLS 315W). SCOPE ALSO INCLUDE UPGRADING CENTRAL INVERTER TO 10Kac, NEW 125A GENERATION PANEL, 200A NEW BACKUP PANEL AND 400A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12730	13041-10001-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	Changes to approved set. All changes are clouded under delta 4, 8, 12, & 14. New wiring type, changes to switchboard details, changes to circuit breaker ratings, and new panel AIC ratings, and added circuits as well as changes to T24. Also revising available dwp fault current and short circuit values on the single line diagram.  New lighting fixtures used with updated lighting and power plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12731	13041-10000-06541	1301 E WHOLESALE ST	90021	14	124-5A215  11	5164010005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	ADDRESS	34.03661	-118.23639	HIGH BAY FLOURESCENT FIXTURES ARE TO BE UL LISTED ON THE FIELD FOR USE IN A WALK-IN COOLER.T24 PLAN CHECK FOR LIGHTING IN A WALK-IN COOLER IN A SINGLE STORY BUILDING.  5000 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12732	12041-10000-20525	1200 W PACIFIC COAST HWY	90744	15	036B201   859	7415001028	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	ADDRESS	33.79019	-118.27836	TENANT IMPROVEMENT; NEW PARAPETS ADDITIONS AND REMODELING EXTERIOR FACADE AND ENTRANCE ALSO NEW ACCESSIBLE RESTROOMS.  RESTRIPE EXISTING PARKING LOT.PLAN CHECK IS FOR TITLE 24-EXTERIOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12733	16041-10000-27236	660 S FIGUEROA ST	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	Plan check for power only.  Installation of new 480/277 V 1,200 distribution board to feed two future restaraunt tenants.  Distribution board ties in to existing electrical system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12734	18041-20001-48746	14930 W DRELL ST pv1	91342	7	225B149   137	2502008034	RA-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.3156	-118.45773	expeditepv1install roof mounted pv system sized 7.6KW AC interconnected with msp.(2) tesla 5KWh batteries	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12735	15041-10000-26814	19855 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.23208	-118.56599	REMOVE AND REPLACE EXISTING LIGHTING TO LED LIGHTS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 8637.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12736	13041-20000-34985	7525 N NITA AVE	91303	3	186B101   275	2023018020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.20729	-118.6138	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12737	18041-10000-45663	1410 N CYPRESS AVE	90065	1	147A217   240	5454035900	PF-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.09708	-118.23107	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12738	19041-10000-10956	1430 S FAIRFAX AVE	90019	10	129B177   465	5068022043	(T)(Q)C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM			Verifications in Progress	07/10/2019 12:00:00 AM	ADDRESS	34.05038	-118.36661	Power plan check for a new 1600-Amp service supplying (3) 150kw dispenser EV changers and (1) level 2 EV charger.(((PROPOSED INSTALL OF EV CHARGING STATIONS IN VONS PARKING LOT. INSTALL OF (1) SWITCHBOARD ASSEMBLY, (3) 150 KW BTC POWER UNITS, (3) 150 KW BTC DISPENSERS AND (1) LEVEL 2 CHARGER Bld #: 19020-10000-00832)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12739	17041-10000-19628	101 N VIRGIL AVE	90004	13	138B197   763	5501007006	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.07372	-118.28703	Title 24 plan check.  T.I. to existing warehouse with new 400 amp service and new lighting, receptacles, and HVAC.  Total area = 2,020 sq. ft.       Building permit #17016-10000-06410	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12740	13041-10000-32649	18650 W DEVONSHIRE ST	91324	12	204B121   133	2729011901	(T)(Q)RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM			Corrections Issued	12/18/2013 12:00:00 AM	ADDRESS	34.25711	-118.54099	pc for power only. new 600A service. not methane. Panel PA pulled under 13041-20000-31703.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12741	17041-20001-00559	1000 W WILSHIRE BLVD Suite 250	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,309 sq. ft.Note: Building application has been generated under 16016-10000-26579	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12742	15041-10001-26812	12777 W JEFFERSON BLVD BLDG E	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	33.9778	-118.41768	CHANGES TO APPROVED SET OF PLAN - CHANGES ARE CLOUDED UNDER DELTA 7 CHANGES ONLY. CHANGES INCLUDE SIZING OF SERVICE ENTRANCE CONDUCTORS. ORIGINAL PERMIT UNDER 15041-10000-26812FULL PC POWER AND ENERGY FOR A NEW (3) STORY COMMERCIAL BLDG. 2000 A SERVICE 480/277 3 PHASE, 4W SYSTEM. SQFT = 52350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12743	12041-20000-09519	11620 W WILSHIRE BLVD 2ND,4TH-COORID	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Expired	05/20/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	ENERGY PLAN CHEK 2ND AND 4TH FLOOR COORIDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12744	11041-10000-07656	11694 W MAGNOLIA BLVD	91601	2	171B169   454	2354005025	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	10/28/2011 12:00:00 AM	ADDRESS	34.16473	-118.38735	UPGRADING PANELS AND ADDING EQUIPMENT TO AN EXISTING TACO BELL RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12745	16041-20001-44699	627 S MORENO AVE	90049	11	126B137    53	4264005018	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			PC Approved	05/26/2017 12:00:00 AM	ADDRESS	34.04428	-118.48553	5.26.2017 - Plan check for modifications to approved set. Update plans to show as-built condition. Add panel AC w/condensing units. Changes clouded delta 1.=======Plan check for power only. New 2 story SFD with basement and attached garage. 1000A service.Note: Electrical permit fees paid under Building Combo permit. Building permit pulled under application number 16010-30000-01744.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12746	16041-10000-37767	10700-11000 S PERSHING DR	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	Yes	9800.28	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	33.93748	-118.43218	PC for new 800A service and 3 pumps. this is for pump station at LAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12747	18041-10000-17127	1653 S ABBOT KINNEY BLVD	90291	11	108B145  1636	4241036038	(T)(Q)CM-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM			PC Info Complete	05/11/2018 12:00:00 AM	ADDRESS	33.98939	-118.46274	PC FOR T-24 ENERGY ONLY FOR Change of use from Retail and Take-out Ice Cream Shop and Retail (No seating, no tables and chairs and no consumption of food and beverage is permitted).SCOPE INCLUDES NEW CIRCUITS LIGHTS AND RECEPTACLES. TOTAL AFFECTED 1045 SQ.FT B#18016-10000-08510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12748	13041-20000-20914	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	33.98489	-118.42552	New feeders, panels, lighting, circuits for  a multi-media/broadcast commercial space.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12749	15041-10001-23167	6601 N CANTALOUPE AVE	91405	2	180B153   566	2238008018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	ADDRESS	34.19051	-118.43466	PC FOR 27 PANEL SOLAR SYSTEM. INVERTER 6KW OUTPUT WITH POWER OPTIMIZERS. PLANS SHOW PANEL UPGRADE PAID UNDER ORIGINAL PERMIT. THIS APPLICATION IS PLAN CHECK ONLY. NO OTHER FEES NEEDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12750	15041-10000-10802	555 W REDONDO BEACH BLVD	90248	15	072B201    97	6120028006	C1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Issued	04/10/2015 12:00:00 AM	ADDRESS	33.89286	-118.28458	FIRE ALARM FOR 2 STORY(E) BUILDING. 99 FIRE ALARM DECIVES, 1 CONTROL PANEL AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12751	19041-20000-37199	1914 W ROSEBUD AVE	90039	13	147A211   192	5443032011	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	PIN	34.09773504	-118.24910975	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 4.29 KW DC/3.8 KW AC. SCOPE OF WORK CONSISTS OF (13) PV MODULES WITH OPTIMIZERS, AND  A 3.8 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12752	12041-10000-23298	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	T.I. to an existing office building Ste#2330 on the 23rd floor.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12753	17041-30000-41647	601 S FIGUEROA ST 37th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Issued	12/14/2017 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing highrise building office T.I. Toatl area: 4,425 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12754	14041-20000-22809	10032 N SWINTON AVE	91343	12	204B137   860	2678010007	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.25302	-118.48587	PV1 SINGLE FAMILY. USING TRANSFORMERLESS INVERTER WITH STANDARD PLAN.USING POWER OPTIMIZERS. TOTAL OF 22 MODULES. 5KW AC SYSTEM SIZE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12755	11041-20000-22200	5900 W WILSHIRE BLVD #120	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM			PC Approved	10/17/2011 12:00:00 AM	ADDRESS	34.06237	-118.35809	s.120 office t.i.Energy, emergencyFire/ Life safety existimg to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12756	10041-10002-09640	6933 W HOLLYWOOD BLVD STE  D	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/03/2010 12:00:00 AM			Corrections Issued	12/03/2010 12:00:00 AM	ADDRESS	34.10171	-118.34135	FIRST  TENANT IMPROVEMENTS: PARTITIONS, CEILINGS, FINISHES, NEW MEZZANINE FLOOR AND STAIRS; ADD FLOOR WITHIN (E) TWO STORY PORTION OF BUILDING TO CREATE A THREE STORY BUILDING. (THE ORIGINAL APPROVED PLAN WAS LOST. PARTIAL PERMIT WAS OBTAINED UNDER# 10041-10000-09640)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12757	14041-10000-34949	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.10311	-118.31242	Plan check for power and energy. Site is an existing 7-story senior-living apartment complex (site is not high-rise). Project includes a new 1600 amp service and associated unit panels. Total lighting area = 20,314 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12758	15041-10000-07058	200 WORLD WAY # 224	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR ENERGY. INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM  ROW. TOTAL AREA 62.5 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12759	15041-10000-35464	21825 W ERWIN ST	91367	3	177B105    25	2146029005	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.18301	-118.6035	INTERIOR T.I. OF (E) COMMERCIAL SPACE.  PLAN CHECK FOR ENERGY FOR CHANGES MADE TO LIGHTING SYSTEM ASSOCIATED WITH NEW PARTITIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12760	17041-10000-25902	5106 E VALLEY BLVD	90032	14	138A235   326	5221002014	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.0712	-118.17285	PC or T24 for new lights in mixed use building containing office and shop areas. Installing new 400A service with three panels, new branch circuits and equipment. Building # 17016-10000-11365. Load under 400A and total sqft of 12200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12761	14041-20001-31953	7900 N BALBOA BLVD	91406	6	189B133   403	2205006902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Expired	06/20/2017 12:00:00 AM	ADDRESS	34.21347	-118.50092	[[[ 5/27/15 Changes to approved set. Adding loads and 8 panelboards to this scope of work ]]]*****Previous Work Description*****PROVIDE ELECTRICAL POWER FORM MAIN PANEL TO NEW SUBPANELS AT 7 DIFFFERENT HANGERS (TANGO, SIERRA, ROMEO, QUEBEC, PAPA, KILO, OSCAR). PLAN CHECK FOR POWER ONLY. PANEL SCHEDULE FOR HANGERS TO BE PROVIDED 11/24/2014 BY APPLICANT. PLAN CHECK FEES ESTIMATED FEES TO BE VERIFIED BY PLAN CHECKER. APPROVED POWER PLAN PROVIDED WITH SUBMITAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12762	17041-10001-32966	11911 W CULVER BLVD	90066	11	111B161  1140	4233020003	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	33.99617	-118.41724	Supplemental for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12763	14041-20000-07802	1319 S OGDEN DR	90019	10	129B177   249	5086015009	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.05248	-118.36406	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12764	10041-20003-17894	11723 N FENTON AVE	91342	7	213B165   170	2531009041	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1041.03	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM			PC Approved	12/21/2011 12:00:00 AM	ADDRESS	34.28324	-118.39296	revise approved energy calculation	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12765	14041-20001-24777	7000 S HOOVER ST Unit #1	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	Fee for expedite only.****New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #1.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12766	16041-10003-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 8. PROVINDING ACTUAL LOAD CALC BASED ON LOWER TI LOADS. PC FOR ADDITIONAL WATER HEATER CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12767	15041-10001-08987	380 W WORLD WAY Terminal 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Approved	08/06/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	((8/6/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3. CHANGES INCLUDE REMOVAL AND ADDITION OF DEVICES.New fire alarm system (full evacuation) for Terminal 4 connector on levels 1-4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12768	13041-10000-30068	9338 W BEVERLYCREST DR	90210	4	147B165   400	4352011012	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.09738	-118.40185	PV1, Install 6.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE6000A-US. 27 modules Hanwha HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12769	10041-10000-03933	13071 W BLUFF CREEK DR	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/25/2010 12:00:00 AM	ADDRESS	33.97022	-118.42386	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12770	16041-20000-40154	3931 N KINGSWOOD ROAD	91403	4	163-5A145  80	2281014005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Issued	11/29/2016 12:00:00 AM	ADDRESS	34.14244	-118.4673	Plan check for the addition of a PV system onto an existing PV1 roof-mounted PV system. System addition size is 5 kWac for a total system size of 10 kWac. System addition consists of (1) inverter and (22) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12771	13041-10000-29035	3458 1/2 W WILSHIRE BLVD	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.06144	-118.29987	"permit to be pulled at EPC counter. pc for energy only. hirise less than 50 occupants and <400A. no emergency lighting. 15 new branch circuits on existing panelchanges on the plans include clarification of daylighting controls, homeruns, time clock override location, and controls on T24 sheets.building description (address taken from 13016-10000-21604): ADD NON BEARING WALLS  AND  CHANGE OF  USE   PORTION  OF THE  BUILDING  FROM COFFEE SHOP TO RESTAURANT  IRREGULAR 35'10"" X 19'11""680 SQ  SUITE  3458 1/2 ON THE  GROUND LEVEL.  ADD  SOFFIT ON  TOP  OF  THE  COUNTER"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12772	19041-10000-53836	7167 N RIVOL ROAD	91307	12	183B089    49	2028038003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Closed	07/01/2021 12:00:00 AM	ADDRESS	34.20126	-118.65542	New roof mounted 12.16KW PV system with 38 @ (320W) PV panels, 38 Optimizers and a 10KW cenral inverter on a single family home.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12773	17041-20000-20907	8951 N SAN FERNANDO ROAD	91352	6	195B169   211	2631016041	M1-1-CUGU, M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.23168	-118.38601	PLANCHECK FOR POWER ONLY. NEW SERVICE UPGRADE TO 600 AMPS FOR MODULAR BUILDINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12774	19041-10000-37192	6200 W FRANKLIN AVE	90028	13	150A189   218	5586024403	R4-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.10503	-118.32418	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING CONTROLS IN AN APARTMENT CORRIDOR. USING EXISTING CIRCUITS. TOTAL AFFECTED AREA IS 282 SQFT. B# 19016-10000-08583	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12775	15041-10000-21133	1307 W SEPULVEDA BLVD #3	90501	15	042B197   227	7347018089	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	33.8138	-118.2996	Full plan check for first time tenant  ( The coffe bean & Tea leaf) owner build out. Main Scope includes (2) panels connecting to an existing 600-Amp service, toal (52) circuits, (2) equipment and 1651-SQ feet for T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12776	13041-10000-26221	100 UNIVERSAL CITY PZ stage  #29	0	4	162B177	2424044015	C2-1, PB-1					1437.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM				replacing high bay luminaires -supplied from existing ckts and lighting area ctrls  for shut-off ctrl;EMERGENCY LUMINAIRES REMAINED THE SAME PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12777	13041-10001-10628	255 E ADAMS BLVD	90011	9	120A207   122	5127036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	34.02379	-118.2657	Supplementary description: Changes to lighting system in scope of approved set.  Supplementary plan checkper inspector request.  +++++++++++++++++++++++++++++++++++++++++++++++++++++++++PERMIT IS FOR EXISTING BRANCH CIRCUITS, LIGHTING LOADS AND TWO RECEPTACLES ON EXISTING BRANCH CIRCUITS, AND TWO NEW CONDENSER UNITS.**********************************************************RENOVATION OF EXISTING LIQUOR STORE. INSTALLATION OF NEW LIGHTING. MINOR CHANGES IN POWER. PLAN CHECK FOR T24 ENERYG ONLY. TOTAL AREA 2720 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12778	18041-20000-48460	18040 W SHERMAN WAY	91335	3	183B125   226	2121023042	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.20091	-118.52659	Plan check for power and energy. Project site is an existing tenant space in an existing commercial building. Project scope is a tenant improvement for a dialysis clinic. Total lighting area = 4,755 sq. ft.Note: Building application has been generated under 18016-20000-40784	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12779	17041-10000-07392	13075 W MONTFORD ST	91331	7	213B161   842	2533003026	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.27786	-118.41775	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(10)MODULES-CSUN 310-72P(10)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12780	16041-20002-15065	11232 W BRIARCLIFF LANE	91604	2	156B169   205	2381020015	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Expired	07/18/2018 12:00:00 AM	ADDRESS	34.12622	-118.3803	CHANGES TO AN APPROVED SET OF PLANS.  INCREASE (1) OF (2) INVERTERS TO 11.4KW.   PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER.  16041-20000-15065PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20.48 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12781	18041-10002-09703	2221 W BERKELEY AVE	90026	13	142-5A207 233	5423010013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM			PC Approved	07/16/2018 12:00:00 AM	ADDRESS	34.08442	-118.2617	PC FOR CHANGES TO APPROVED SET. CHANGES INCLUDE RELOCATING MODULES ON THE ROOF-LAYOUT, 2 MODULES HAVE BEEN REMOVED. ALSO CHANGES ON THE SINGLE LINE DIAGRAM. THIS IS PLAN CHECK ONLY!PERMIT PAID UNDER 18041-10000-10465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12782	14041-20001-27548	7842 N TEESDALE AVE	91605	2	189B161   705	2305017009	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM			PC Approved	10/11/2014 12:00:00 AM	ADDRESS	34.21324	-118.41045	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.2kW.(2) ABB PVI-3.6-OUTD-S-US-Z-A transformerless inverter(34) Kyocera KD255GX-LFB3 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12783	09041-10001-24406	3655 S GRAND AVE	90007	9	118-5A203 278	5122023028	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	05/27/2011 12:00:00 AM	ADDRESS	34.01726	-118.27819	REVISED THE SIZES  OF TWO SIGNS( A METAL PANEL SIGNAGE AND A HISTORY PANEL SIGNAGE)   INSIDE AND A SIGN TOWER OUTSIDE A RETAIL STORE .BUILDING PERMIT FOR THE TOWER OR POLE SIGN  (6' X 6' X20' ) IS 09048-10000-01907	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12784	19041-10000-08031	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	04/22/2021 12:00:00 AM		Permit Finaled	04/27/2022 12:00:00 AM	ADDRESS	34.21499	-118.4422	Power plan check for a mediuNote:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application #19041-10000-08035	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12785	15041-10000-26224	5439 N SUNNYSLOPE AVE	91401	4	174B157   981	2344007016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.16965	-118.42701	PV1 PC FOR ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY RESIDENCE. (2) INVERTERS: 12KW , (40) MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12786	17041-10001-08299	8417 W MELROSE PL	90069	5	141B173   443	5528002040	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Info Complete	04/13/2017 12:00:00 AM	ADDRESS	34.08377	-118.37377	PC Changes to approved set under delta 1scope inclueds changes to luminaire count ( additon of 90 units)and some changes to receptacle.  T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2966 SQ. FT. b#17016-40000-06140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12787	18041-10000-44893	560 N WESTERN AVE	90004	13	141B193   927	5521014007	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Issued	11/27/2018 12:00:00 AM	ADDRESS	34.08149	-118.30894	PLANCHECK FOR T24 ENERGY. TI OF EXISTING BUILDING . CHANGE OF USE FROM RETAIL TO OFFICE ON 2ND FLOOR . LESS THAN 400 AMPS OF CONNECTED LOAD. 4728 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12788	17041-10000-16635	5300 S DENKER AVE	90062	8	108B193   397	5003015036	[Q]C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	33.99396	-118.30439	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 18150 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12789	15041-20002-01844	416 W 8TH ST	90014	14	127-5A209  58	5144018030	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	ADDRESS	34.04471	-118.25646	Changes to approved set.  Revisions to SLD layout and value engineering of copper to aluminum feeders.  Changes to branch circuit layout of hotel guest rooms.   Clouded changes only.  ((High rise 13 stories. Adaptive reuse to hotel.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12790	16041-20000-45580	21600 W OXNARD ST Ste 550	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.179	-118.6002	TI to (E) commercial office in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12791	14041-10000-27592	216 S ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM			PC Info Complete	11/13/2014 12:00:00 AM	ADDRESS	34.04645	-118.23792	PLANCHECK FOR POWER AND ENERGY. Change of use from Manufacturing to  a Club. ANGEL CITY BREWERY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12792	16041-10000-38230	1253 N BISHOPS ROAD AUDITORIUM	90012	1	136-5A215  10	5414019007	[Q]R3-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.06976	-118.23428	Installation of a new methane gas control system for private school, methane zone design level 3. (53) Control Devices, (1) Control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12793	19041-10000-22406	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM			PC Info Complete	06/12/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	PC (Energy only ) for TENANT IMPROVEMENT IN EXISTING OFFICE AT APRON LEVEL UNDER GATE 40. area scope 565sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12794	19041-10000-19330	4280 S HILLCREST DR	90008	8	114B181   384	5031017008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.00818	-118.35266	PC FOR PV SYSTEM. SYSTEM CONSISTS OF 28 MODULES (SPR-X22-370-E-AC) WITH MICRO INVERTERS (SUNPOWER ACPV), (1) 125A COMBINER. 1 POWERWALL BATTERY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12795	17041-20000-39892	3000 S ROBERTSON BLVD suite 255	90034	10	123B169   884	4311033015	C4-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.03242	-118.39001	PLANCHECK FOR T24 ENERY. TENANT IMPROVEMENT FOR OFFICES. 1320 SQFT. SUITE 255	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12796	17041-10001-00486	11668 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.20103	-118.38683	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES TO FEEDER SIZE AND GROUND. NO OTHER CHANGES. PC ONLY. PERMIT STILL UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12797	19041-20000-05145	5232 N WILLOW CREST AVE 1-9	91601	2	171B177   487	2416028030	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			02/12/2019 12:00:00 AM	12/23/2020 12:00:00 AM		Permit Finaled	06/02/2024 12:00:00 AM	ADDRESS	34.16582	-118.362	800A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12798	13041-10000-17136	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	T.I. to restaurant.  Install new panels, transformer, and branch with panel bus rating at 600A and load exceeds 400A.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12799	09041-20007-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to previously approved set of plans.  PLAN CHECK ONLY for ""DELTA 218""  on pages E302, E302B, E729 to add 38.8A to DBP2EH.         <<<T. I. - new medical office bldg.(NEW HIGH RISE BUILDING, MEDICAL OFFICE, SHELL UNDER PCIS 08041-20000-22411)>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12800	15041-20001-21180	12561 N COMETA AVE	91340	7	219B157   299	2513020026	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM			PC Approved	07/13/2015 12:00:00 AM	ADDRESS	34.29795	-118.42459	Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 6.45 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12801	16041-20000-22154	1007 N WESTERN AVE	90029	13	144B193  1074	5536021025	C4-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.08867	-118.30942	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MCDONALDS. 2762 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12802	16041-10000-36531	900 N NORTH BROADWAY #1000	90012	1	135A215   238	5414013901	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.06408	-118.23726	Full PC for power and energy for first time tenant. Scope includes new lights, receptacles and sign lighting for  area 1599 sqft.  PC two subpanels and one 75 KVA transformer. **TI WORK ON 1599 SF OF THE TOTAL FLOOR AREA. NEW WALL, POWER, LIGHTING AND FINISHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12803	17041-10001-04818	823 N POINSETTIA PL	90046	5	141B181   149	5526007031	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Apartment			09/20/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.08594	-118.34878	T24 PC FOR LIGHTING UPGRADES IN COMMOM AREAS. pc only permit covered under master	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12804	18041-10002-48894	22015 W TULSA ST	91311	12	207B101   587	2723005064	(T)(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.26706	-118.60723	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE PV INTERCONNECTION AND RELOCATION OF EQUIPMENT INSIDE GARAGE TO BE PROVIDED WITH PHYSICAL PROTECTION. ALL CHANGES UNDER DELTA-2 ONLY.ORIGINAL PERMIT NEW ROOF MOUNTED 15.12 KW(DC) PV SYSTEM CONSISTING 42 PV MODULES AND 2 INVERTERS (SE7600H-US & SE6000H-US)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12805	15041-10000-42466	735 W 157TH ST	90247	15	072B197   322	6120005022	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	33.88906	-118.28803	PV1 4.2KW AC roof-mounted system with (14) Sunpower E20-327 modules, (1) PVI 4.2-OUTD Power One inverter interconnecting through the service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12806	10041-20000-08466	310 N FAIRFAX AVE	90036	5	138B177   379	5527037030	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	ADDRESS	34.07655	-118.36127	energy plan check exterior lighting chase bank	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12807	15041-20000-10745	3855 W BOYCE AVE	90039	13	156A207    84	5435008019	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.12314	-118.2626	Plan check for PV1 roof mounted 6.0kW system with 16 modules(SUNPOWER SPR-X21-3545) and 1 inverter(SB6000TL0US-22)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12808	14041-10000-01495	8012 S RAYFORD DR	90045	11	099B157   620	4114035019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	33.96385	-118.42558	PV1, Install 7 kW DC roof-mounted solar array for a two story house, interconnect with existing service panel.(1) Transformerless inverter(s): SOLAREDGE SE6000A-US. (28) Modules: TRINA SOLAR TSM-250PA05.18.(28) Optimizers: SOLAREDGE OP250-LV-MC4CM-2NA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12809	16041-20000-09705	16133 W VENTURA BLVD Suite 1080	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.15675	-118.4847	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,864 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12810	18041-10000-46800	700 W 7TH ST U270-S270	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.04797	-118.25815	FULL PLAN CHECK FOR MEDICAL OFFICES. SCOPE OF WORK INCLUDES NEW PANELS, CIRCUITS AND LIGHTING. TOTAL SQ. FT. 25790CONNECTED LOAD > 400AMPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12811	15041-10002-43361	767 S ALAMEDA ST Bldg 2	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Closed	05/19/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	Change to approve set by upsizing (3) transformers from 1000KVA to 1500KVA, adding (3) 12,000 Amp distribution board. feeder and fault current being update, and (3) electrical room being relocated. minor changes also being applied to the floor plan. All changes are under delta-11.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12812	15041-20000-18081	1463 W 3RD ST	90026	13	133-5A207 248	5153027004	C2-1	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	PIN	34.05946249	-118.26348513	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR FOOD STORE. 2011 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12813	16041-10010-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	PIN	34.2363795	-118.55851216	Delta 31 changes to an approved set. change include adding switch, lighting fixtures, and junction boxes in units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12814	13041-10000-08959	5960 N SEPULVEDA BLVD	91411	2	177B145   497	2243019026	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.17803	-118.46469	FA WITH CENTRAL STATION MONITORING ORCHARD SUPPLY HARDWARE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12815	14041-10000-06520	13450 W MAXELLA AVE #220	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	33.98645	-118.44148	Tenant improvement for 1,373 sq. ft. beauty salon.  Title 24 plan check for changes to lighting system.Permit fees calculated under inspection fees.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12816	11041-10000-15954	5120 N ZELZAH AVE	91316	5	171B129   238	2162012010	QC1-1VL, QP-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.16408	-118.52188	T.I.  Existing 7-11.  Replacing the light fixtures in the retail area only.  Light fixtures are being replaced by LED's.  PLan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12817	18041-20001-22020	6212 N YARMOUTH AVE	91316	5	177B129   162	2123030012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM			PC Approved	07/10/2018 12:00:00 AM	ADDRESS	34.18274	-118.51942	Revision to approved set of plans.  Relocation of equipment, slight system downsize: (16) AC modules with total system size 5.52 kW.  $2.67 plan check fee per State Senate Bill SB 1222.(((Plan check for PV roof mounted system. System size: 5.76kW with 18 AC Modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12818	15041-20000-16494	21550 W OXNARD ST Suite 1100	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 18,448 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12819	10041-10000-20988	10927 1/2 W PICO BLVD	90064	5	126B157  1025	4322004017	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM			PC Info Complete	11/09/2010 12:00:00 AM	ADDRESS	34.03942	-118.43034	Ti in a restaurant. New service, panels and circuits. Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12820	16041-10000-05981	2670 E ROSEVIEW AVE	90065	1	145-5A219 132	5453003018	RD3-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Expired	03/21/2018 12:00:00 AM	ADDRESS	34.0938	-118.22704	PV1 roof mounted solar system installation to a single family home. Inverter is rated at 3.0 kw, (9) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12821	12041-20000-19614	4649 N LOWELL AVE	91042	7	201B205   787	2571005038	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2012 12:00:00 AM			PC Approved	10/04/2012 12:00:00 AM	PIN	34.24344252	-118.26641438	Plan check for PV system. sfd. 1.53kW. ****THIS APPLICATION IS AN ERROR....PLEASE IGNORE*******	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12822	16041-10001-33314	417 E 104TH ST	90003	8	090A207    39	6063013016	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	33.94204	-118.26666	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 6 PV MODULES(KYOCERA KU-60), CENTRAL INVERTER(ABB PVI-3.0), & LOAD CENTER. TOTAL SYSTEM SIZE 3.3KVA.(PLAN CHECK FOR LOAD CENTER AND PLAN CHECK)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12823	14041-10000-04166	333 S GRAND AVE 43RD FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	Tenant improvement for office suite in Wells Fargo tower - 43rd floor.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12824	12041-20000-19749	12404 W VENICE BLVD	90066	11	111B153   231	4235013023	[T][Q]C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.00336	-118.43363	Plan check for power and energy. 3083sqft. 1 story commercial. Proposed coffee shop.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12825	10041-20000-16953	8403 W 3RD ST	90048	5	138B173   746	5511014019	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	11/18/2010 12:00:00 AM	ADDRESS	34.07318	-118.37335	LIGHTING IN ART GALLERY. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12826	19041-10000-29047	12666 W PALMS BLVD	90066	11	114B153   815	4246003002	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.00796	-118.4426	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF EQUIPMENT AND ARE CLOUDED ORGINAL PERMIT 19041-10000-20906	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12827	19041-20000-49805	1136 E ROSE AVE	90291	11	114B145   160	4243024011	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.00545	-118.45975	PV1.  Install new 5.22 kW DC/ 7.6 kW AC roof mounted grid tied PV system with 9.8 kWh energy storage system.  (18) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12828	15041-10000-18114	1000 S HOPE ST 1ST FLOOR	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.04346	-118.2617	FIRST TIME TENANT IN THE 1ST FLOOR OF A HIGH RISE BUILDING. MEDICAL OFFICE THERAPY TREATMENT TENANT WITH EXAM ROOMS. FULL PC, POWER AND ENERGY. TOTAL SQ. FT. 5880.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12829	13041-20000-23765	20051 W VENTURA BLVD UNIT M	91367	3	174B113   439	2166001031	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	PIN	34.1716613	-118.57023176	T24 FOR VET TI WORK. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT. TOTAL SQRFT 4816	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12830	10041-20000-21161	15260 W VENTURA BLVD #1000	91403	5	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	12/01/2010 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check T24 energy for lighting on 10th floor. All circuits are existing. Emergency ckt and exit signs are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12831	17041-10000-11731	10501 N LARWIN AVE #6	91311	12	207B101   211	2723011***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Issued	04/11/2017 12:00:00 AM	ADDRESS	34.26145	-118.61391	ROOF MOUNT PV SOLAR ON (E) SINGLE FAMILY CONDO BUILDING.System size is 5.2kwAC  with a total of 16 AC modules. (SPR-E20-327-C-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12832	12041-10000-16167	10585 N LEV AVE	91345	7	207B149   600	2617009020	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.26296	-118.44692	Plan check for new roof mounted 6.8KW Photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12833	19041-20000-42597	22254 W SCHOOLCRAFT ST	91303	3	183B101   569	2024034008	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.19591	-118.61206	NEW ROOF MOUNTED 3.72 KW PV SYSTEM WITH 12 SOLAR MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12834	19041-10000-22823	16461 W VANOWEN ST	91406	6	183B137   464	2224019020	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Issued	06/14/2019 12:00:00 AM	ADDRESS	34.19403	-118.49217	Plan check for removing HID fixture and repace with new LED fixture that cover a total lighting area of 4,200-SQ FT, outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12835	14041-20000-28480	20800 W DEARBORN ST	91311	12	198B109   153	2748037018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Issued	11/13/2014 12:00:00 AM	ADDRESS	34.23712	-118.58631	SERVICE UPGRADE 1600AMP TO EXISTING COMMERCIAL BUILDING.  ADDING EMPTY PANELS FOR FUTURE TENANTS. PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12836	17041-20000-10311	7034 N BALBOA BLVD	91406	6	183B133   445	2225020027	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.19844	-118.50092	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12837	19041-10000-17589	3049 W 8TH ST	90005	10	132B197   456	5094010009	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.03	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.05789	-118.29334	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12838	17041-20000-45315	11920 W JEFFERSON BLVD	90230	11	105B165   381	4220006043	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	33.98492	-118.40319	"Tenant improvement/change of use from warehouse to new gym and parking garage.  Plan check for energy.  ""COMPLY WITH DEPARTMENT ORDER effective date 02/16/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12839	16041-10001-26608	1200 S BROADWAY Build. 12	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.03792	-118.26026	01/30/16Changes to an approved set of plans. All changes are clouded under delta 2. Changes include revising voltage drop calculations,  battery calculations,  changing the model and manufacturer for the fire alarm equipment, and adding 46 FA devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12840	16041-30000-35155	850 N WILCOX AVE 1-23	90038	13	144B185  1247	5533027025	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.08678	-118.33082	Installation of fire alarm system in new 4 story 23 unit apartment building.  Total system size = 104 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12841	17041-20000-36485	400 S HOPE ST 13TH FLOOR	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.05199	-118.25366	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS ON THE 13TH FLOOR. HIGH RISE. 1936 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12842	18041-10000-38075	12616 W SHERMAN WAY	91605	2	183B161    62	2324020034	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.20097	-118.40799	Tenant Improvement to existing Restaurant (Interior and Exterior). T-24 ONLY. BLDG PERMIT: 18016-10000-27310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12843	19041-20000-09786	24212 W ST EDENS CIR pv1	91307	12	183B089   391	2028034014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.19719	-118.65219	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12844	10041-10000-18750	10250 W CONSTELLATION BLVD 35th floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	12/27/2010 12:00:00 AM	ADDRESS	34.05735	-118.41746	Ti in an existing office building. Plan check for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12845	13041-10011-26820	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			06/15/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	33.97574	-118.39042	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 10.1 - CHANGES INCLUDE DOG SPA AREA INSTEAD OF ELECTRIC ROOM. NEW WIRING AND TITLE T24 PROVIDED. NEW ENGINEER PROVIDED FOR DELTA 10.1 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12846	17041-10000-25454	8 S CHESTER PL	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.03102	-118.27718	PLAN CHECK FOR FIRE ALARM SYSTEM - SCOPE INCLUDES 1 FIRE ALARM PANEL AND 95 DEVICES FOR EXISTING 4 STORY OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12847	10041-20000-23571	7929 N RUFFNER AVE	91406	6	189B137    40	2205009039	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.21441	-118.49704	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12848	19041-10000-18610	720 S CERES AVE	90021	14	126A213   690	5146004038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	ADDRESS	34.03749	-118.24356	remove indoor hid fixtures and replance with new led fixtures - t24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12849	13041-20000-18076	222 W 6TH ST 3rd floor	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	33.73887	-118.28305	Change to lighting/receptacles in an existing high-rise office building on the 3rd floor (Southside).  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12850	18041-20001-24842	1234 S SPAULDING AVE	90019	10	129B177    92	5085025007	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2018 12:00:00 AM			Corrections Issued	10/12/2018 12:00:00 AM	ADDRESS	34.05346	-118.36096	10-12-2018 Changes to an approved set of plan, changes include update as built drawing and decrease conductor size from roof J-box to combiner box.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12851	14041-20000-34986	7123 W SUNSET BLVD	90046	4	147B181   636	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.09815	-118.34512	TI pizza place energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12852	18041-20000-47788	20352 W ALERION PL	91364	3	168B113    52	2166044022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.16017	-118.57776	PV1.  Install 13.65 kW roof mounted grid tied PV system.  (42) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12853	19041-10000-17870	4515 N EAGLE ROCK BLVD	90041	14	157-5A221  80	5473037007	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	08/12/2020 12:00:00 AM	ADDRESS	34.12659	-118.219	PC FOR POWER AND ENERGY(LOT 33-38). SCOPE INCLUDES A NEW 800A SERVICE FOR 6 SFD AND COMMERCIAL SPACES. TOTAL AFFECTED AREA IS 42218 SQ. FT. ENERGY PC UNDER MASTER 19041-10000-17858.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12854	16041-30001-45781	380 WORLD WAY Tunnel E	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	"02-06-2018 Changes to an approved set of plan LAX Project 5 Midfield Satellite Concourse North(MSCN) TUTL-E. Changes include from feeder to busway, circuit revision, lighing ajustment. Changes apply to delta 1 only. *****************************Previous Work Description**************************Full Plan check. Addition to (E) Bradley West Terminal. Install new lighitng, power, and emergency power to LAX MSC TUNNEL-EAST building. Total area: 37000 sq. ft.  *Scope and plan check is noted ""UNDER TUNNEL EAST PROJECT"" B#16014-10000-02498"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12855	19041-10000-30861	3991 S WESTERN AVE	90062	8	114B193   185	5035008024	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.0116	-118.30912	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12856	19041-10000-20908	9517 N KEOKUK AVE	91311	12	201B113  1040	2748024041	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.2434	-118.57465	[E-plan] PV1. 10kW AC Rooftop solar system on (E) SFD. Install 11.88kW DC ROOFMOUNT PV, 36 MODULES, 1 INVERTER, 36 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12857	15041-10000-14205	5527 W HOLLYWOOD BLVD	90028	13	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.10188	-118.31024	FIRST TIME TENANT-WABA RESTAURANTFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12858	16041-20000-30905	4858 N VAN NUYS BLVD Suite B	91403	4	169-5A151  96	2248006001	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Issued	08/30/2016 12:00:00 AM	ADDRESS	34.15928	-118.4485	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 745 sq. ft.Note: Building application has been generated under 16016-20000-20020	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12859	13041-10000-07263	14647 W MORRISON ST	91403	2	169-5A149  36	2263027001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.16043	-118.45252	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 6.867 KW. [INVERTER: SUNPOWER SPR-6501F-1 UNI] [SOLAR MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12860	14041-20001-17398	5268 N TUJUNGA AVE	91601	2	171B173   338	2350017008	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM			PC Approved	06/16/2017 12:00:00 AM	ADDRESS	34.16676	-118.37882	[[6/16/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO LOBBY AND CORRIDOR LIGHTING . APPROXIMATELY 6000SQFT. EMERGENCY LIGHTING EXISTING TO REMAIN ]]]Plan check for power energy on new built hotel, 4 stories, with 43 guestrooms  and 1 dwelling unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12861	18041-20000-43802	6130 N NEVADA AVE	91367	3	177B101   329	2146003035	R3-1, R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.13	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.18174	-118.60982	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  new load connected to an existing service plan check for power and indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12862	19041-20000-06099	5670 W WILSHIRE BLVD 19TH FL	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	T24 PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL BUILDING,19TH FLR, LIGHTING ONLY FOR CORRIDOR, RESTROOMS, AND LOBBY. TOTAL SQUARE FOOTAGE = 645 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12863	14041-20001-24807	7000 S HOOVER ST	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	expedite feesNew roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for House panel.  System size 2.08KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12864	18041-10000-45342	5999 W CENTER DR	90045	11	102B169   959	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	33.9761	-118.38876	PLAN CHECK FOR FIRE ALARM SYSTEM FOR 5 STORY EXSITING COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES 495 DEVICES AND 1 CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12865	14041-20000-16581	115 S LA BREA AVE	90036	5	138B181   919	5513019013	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	ADDRESS	34.07306	-118.34425	Tenant improvement for retail store in (E) lowrise commercial building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12866	13041-20000-34240	17584 W TUSCAN DR	91344	12	222B129   259	2601044015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.30243	-118.51683	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2 KWAC. 20 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12867	17041-20000-08826	15701 W LASSEN ST	91343	12	201B141   178	2661029001	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.25025	-118.47425	Plan check for a PV1 roof-mounted PV system. System size 7 kWac and consists of (28) modules, (28) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12868	15041-20001-30634	7807 N TUJUNGA AVE	91605	6	189B173   640	2311010007	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2015 12:00:00 AM			Reviewed by Supervisor	09/23/2015 12:00:00 AM	ADDRESS	34.21234	-118.37923	Expedite fees only.       Installation of new roof mounted solar array on existing single family dwelling.  Total system size = 4 kWac.  Two inverter system with interconnected battery bank feeding critical load panel and regular panel with new manual transfer switch.  Transfer switch and critical load subpanel to be included on seperate permit..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12869	14041-10000-35658	7121-7131 N WOODLEY AVE	91406	6	183B141   198	2224009039	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.19983	-118.48386	Plan check for a new fire alarm system. Project site is a new 4-story, 126-unit apartment building. Fire alarm system consists of (1) FACP, and (394) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12870	10041-10000-24670	101 W MANCHESTER AVE	90003	8	097-5A203 326	6040011025	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.00	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	33.96025	-118.27434	TI IN AN EXISTING COMMERCIAL BUILDING. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12871	17041-10002-19302	380-384 WORLD WAY MSC-F/A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM			PC Approved	10/17/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	Fire alarm design changes to permitted set of plans ; Changes are the addition of VLF-250 and VLF-500 AIR SAMPLING SMOKE DETECTORS; CHANGES ARE CLOUDED AND MARKED AS DELTA 5.LIST OF SHEETS HAVING THE CHANGES ARE WITH THE SET OF PLANS(((((((((New Fire alarm system at the Midfield Satellite Concourse of LAX. (135) panels,  (5309) devices	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12872	15041-20000-22583	7608 COURAGE WAY	91405	6	186B145  1162			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20893778	-118.46419302	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12873	18041-20000-22411	11433 W ALBERS ST	91601	2	174B169  1079	2350007071	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Apartment			06/15/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.17056	-118.38016	Plan check for a fire alarm system for a 4-story, 59-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (113) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12874	17041-30000-29830	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	33.97451	-118.42531	Plan check for Title 24 only in existing space. T.I. in conference room. Total area: 587 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12875	15041-20001-43776	6719 N GLADE AVE	91303	3	180B101   127	2139007009	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM			PC Approved	01/25/2016 12:00:00 AM	ADDRESS	34.19253	-118.60826	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Plan check is for the addition of 3 kWac system onto an existing 3.6 kWac system. New system consists of (1) inverter, (14) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12876	14041-20000-28733	9958 N CALVIN AVE	91324	12	204B117   576	2726020004	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.25164	-118.55515	PV1.  Install 7.28 kW DC roof-moutned, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12877	19041-10000-03960	1629 E 103RD ST A	0	15	091-5A213 142	6048013053	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	PIN	33.94485795	-118.24448387	T-24 ENERGY ONLY PLAN CHECK FOR A TI IN A RETAIL STORE. NO CHANGE OF USE. SCOPE INCLUDES NEW 225A SERVICE, NEW 50A SUBPANEL, CIRCUITS, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 990 SQ.FT  B#09016-10000-11228	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12878	13041-10000-28965	6832 S VICTORIA AVE	90043	8	102B185   633	4006024019	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	33.97592	-118.33222	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHTING FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. WAREHOUSE 1 AND 3.  DIFFERENT LTGS FORMS FOR EACH WAREHOUSE. BOTH ON SAME ADDRESS. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12879	18041-20000-44580	4480 N KESTER AVE	91403	4	166-5A149  40	2276003***	C2-1L, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.15197	-118.45649	Plan check for replancemet of the cooling towers, 600A disconnecting means for temporary chiller and associated loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12880	16041-20000-04452	100 W WORLD WAY SPACE 126-F&B	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	PIN	33.94684048	-118.40128468	Full plan check for an LAX airport terminal restaurant.  New kitchen equipment and lighting. space 126 F&B restaurant/bar	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12881	13041-10000-33004	1954 S FEDERAL AVE	90025	11	126B149  1051	4261026019	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.0386	-118.44855	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 4.25KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(17) TRINA SOLAR # TSM-250(17) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12882	13041-20001-35087	6222 N KESTER AVE 1-22	91411	6	178-5A149 166	2241016012	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Approved	02/12/2016 12:00:00 AM	ADDRESS	34.18315	-118.4573	02/12/2016 Changes to an approved set of plans. Changes have been clouded and marked as Delta 1. Electrical distribution system is now series-rated for 100 kAIC.*****Previous Work Description*****PC FOR POWER AND ENERGY. ENERGY FOR PARKING. LOW RISE RESIDENTIAL. NEW 22 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12883	18041-10000-35170	12100 W WILSHIRE BLVD # 1800	90025	11	126B145   273	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM			PC Approved	09/14/2018 12:00:00 AM	ADDRESS	34.0438	-118.46755	TI INAN EXISTINGF OFFICE AREA IN SUITE #1800.T-24 ENERGY ONLY === PLAN CHECK ONLY === ELECTRICAL PERMIT: 18041-40000-31250BUILDING PERMIT # 18016-10000-21963	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12884	15041-10000-08389	2300 E PACIFIC COAST HWY	90744	15	033B217     3	7428008905	M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	33.79043	-118.22853	plan check for power only. PROJECT - PHASE 1B WORK PER NABIL: Replace (2) section-21 from (2) 1200-Amp  switchgears  MCC1 and MCC2 ( 1 section per each switchgear).No load apply to the sections until Phase-2 permit is pulled.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12885	14041-10000-33554	6300 W WILSHIRE BLVD	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.06319	-118.36591	Energy plan check for a office T.I in a high rise building (design build).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12886	14041-10000-16191	1431 W KNOX ST #200	90501	15	057B197   111	7351002029	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.85442	-118.29964	permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A. emergency lighting installed. BLDG#:14016 10 11760:DEMO EXIST PARTITION WALLS/ REMOVE EXIST SUSPENDED CEILING SYSTEM/ ADD NEW PARTITION WALLS TO CREATE NEW OFFICE AND RestRooms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12887	17041-20002-14624	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.23342	-118.3809	05/22/2019 Changes to an approved set. All changes have been clouded. Changes include the addition of (1) 100 kW generator and related distribution equipment. *****Previous Work Description*****PC FOR T24 ENERGY ONLY. INSTALLING NEW 200A SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12888	16041-10000-20667	1667 E 50TH PL	90011	9	111A213   248	5106024011	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	33.99715	-118.24408	PV1 INSTALL NEW 2.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(10) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12889	18041-20001-36274	17600 W MCCORMICK ST	91316	5	171B129   167	2257005039	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM			PC Approved	10/23/2018 12:00:00 AM	ADDRESS	34.16571	-118.51677	Expedite per applicant requestPlan check for PV roof mounted system, system size: 19.101 KW AC CEC with 74 modules and 74 microinverters connected to 400A panel Service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12890	16041-10001-09550	1134 S KENMORE AVE	90006	1	129B197   636	5078023020	R3-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.04989	-118.2967	This is PC only per field request. No additional equipments, permit under 16041-90000-09550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12891	16041-10001-07393	9625 N AQUEDUCT AVE	91343	12	201B141   403	2671008023	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.24553	-118.47405	EXPEDITER PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.02KWdc / 10.0KWac. (40)MODULES-CANADIAN SOLAR CS6P-255P(1)INVERTER-SOLAREDGE SE10000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12892	17041-20000-18329	9240 N KENNY CT	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.23871	-118.45912	Plan check for solar pv system, roof-mounted on SFD.3.84kW ungrounded sysetm. (12) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12893	18041-10000-20563	1950 E 20TH ST	90058	14	118-5A215  82	5167006009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.0179	-118.23832	"""0$ permit fees due to senate bill 1222, AB 1414""PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 75.14 KW. (246) SUNPOWER P-17 355 KW SOLAR PANELS(3) SOLAR EDGE 30K"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12894	13041-10000-11406	1600 N ECHO PARK AVE	90026	13	141A209   143	5420028022	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.0816	-118.25437	Express permit for this title 24 plan check application was issued under 13041-10000-16618PLAN CHECK FOR TITLE 24 FOR INTERIOR LIGHTING OF A GAS STATION CONVENIENCE STORE. FULL PLAN CHECK SUBJECT TO INSPECTORS REQUEST (IF DETERMINED TO BE A HAZARDOUS LOCATION).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12895	19041-20001-33696	20341 W FULLBRIGHT PL	91311	12	207B113    64	2707004010	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM			PC Approved	09/10/2019 12:00:00 AM	ADDRESS	34.26563	-118.57627	CHANGES TO APPROVED SET DELTA 1 CHANGE THE MAIN SERVICE PANEL. <<<Plan checkf or PV roof mounted system, PV System size: 10.88KW DC, 9.8KW AC with 32 PV Modules and 32 Microinverters>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12896	17041-10001-16260	1740 S CRENSHAW BLVD	90019	10	126B185   575	5072002016	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	34.04243	-118.32944	PC TO REPLACE LOST SET OF PLANS. THIS IS PLAN CHECK ONLY!!PC for a PV1 Sytem on a single family residential rooftop. Total size of (21) Microinverter system is 7.035KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12897	13041-10000-13096	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.05554	-118.41342	permit to be pulled at EPC counter only. pc for energy only. TI TO EXISTING SPACE. part of 34 STORY BLDG. (N) LIGHTS+EXIT SIGN in Parking structure (level 5 of parking garage which is a parking lot)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12898	18041-10000-38874	5625 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	33.93197	-118.382	Remove Indoor/outdoor HID fixtures and replace with new LED fixtures - T-24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12899	16041-20000-41240	3201 S HOOVER ST Suite 1840	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT TO NEW CORE AND SHELL. NEW RESTAURANT.  UNIT 8-D1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12900	10041-20000-02708	333 S HOPE ST 47 Floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	02/26/2010 12:00:00 AM		Permit Finaled	05/25/2010 12:00:00 AM	ADDRESS	34.05326	-118.25292	T.I. work in office building. This plan check is only title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12901	16041-10002-20256	8500 W BEVERLY BLVD 628	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Issued	06/21/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	SUPPLEMENTAL PC FOR T-24 (16041-10000-20256). CHANGES CLOUDED UNDER DELTA 7. this permit is for new contractor to finish work inside portion of footlocker - house of hoops area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12902	15041-20000-09524	420 S GRAND AVE	90013	14	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	PIN	34.05085086	-118.2528414	Plan check for the addition of a 4,160 V standby switchgear. relocate existing building loads and standby system. addition of small load center for portable generator loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12903	19041-10000-28944	2911 W EXPOSITION PL Units2	90018	10	117B185  1312	5044011026	CM-1-SP, RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02047	-118.32807	Plan check for a PV2 3.00kw AC / 2.6KW DC  roofmounted system with (1) inverter and  (8) modules interconnecting through the main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12904	11041-10000-26418	3650 W MARTIN LUTHER KING, JR BLVD Ste 144	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	T.I. to an existing restaurant space at the Crenshaw Mall.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12905	15041-20001-07432	3800 S WESTERN AVE	90062	8	117B193   782	5036008006	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM			PC Approved	04/06/2015 12:00:00 AM	ADDRESS	34.01723	-118.30873	EXPEDITE PER APPLICANT REQUEST[PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 22.8KW INTERCONNECTED WITH 400A MSP. GROUNDED SYSTEM.(88) QCELL Q.PRO-G3 260W MODULES(2) FRONIUS 11.4 UNI INVERTERSNote: Solar clearance obtained under previous set of plans under permit #14041-20000-35638. This plan is being resubmitted due to the system being redesigned under request of DWP (reducing wattage from 33.8kW to 22.8kW).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12906	13041-20000-19095	22300 W MULHOLLAND DR PV-2-BLDG 1	91364	3	165B101   186	2173001015	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.14916	-118.61059	PV-2? Plan check for PV system for church. Transformerless. Two 27kW inverters for 54kW total. Roman Catholic Bishop of LA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12907	12041-10002-22864	108 E 5TH ST	90013	14	129A211   204	5148019010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			12/15/2014 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.04636	-118.2484	Changes to approved set - Delta 1 revisions.  Changes associated with elevator motor loads.  (((((Modifications to approved set submitted per inspector request.  Additional load to basement panel HG for 2 sump pump circuits, compressor unit, and fan coil.  )))))(((Plan check for power and energy. Add 2-stories to existing 3-story building resulting in a 5-story building.  Remodel and renovation of existing building to new mixed-use of 69-unit affordable housing development with ground floor future retail spaces. New 2000A service. (1600A supplying residential/house + 600A future retail). Modification to seperate fire alarm has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12908	16041-10000-03326	5824 W 85TH PL	90045	11	096B169   484	4125006019	(T)(Q)RAS3-1	West Los Angeles	Westchester - Playa del Rey			2771.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Expired	03/06/2018 12:00:00 AM	ADDRESS	33.96029	-118.38318	PV1, NEW 4.19 KW DC/ 3.60 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MODULES: KYOCERA KU2606XPA(1) INVERTER: ABB PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12909	12041-20000-19823	4150 N ARCH DR	91604	2	162B173   159	2366023018	[Q]R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.01	Electrical	Electrical	Apartment			08/22/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.1427	-118.37152	Replace fire alarm control panel.  All non-addressable devices remain the same.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12910	14041-20000-00985	6500 W 84TH ST	90045	11	096B165    72	4108012019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	33.96282	-118.40179	pv1 single family dwelling. total system size 6kw ac using 2 stransformerless inverters nonstandard plan. total of 18 modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12911	13041-10001-36039	11362 W DONA TERESA DR	91604	2	159B169   657	2381010009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.1293	-118.38081	Expedited RSES plan check per applicant request.{{PV1, Install 5 kW DC roof-mounted solar array for a two story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (20) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12912	17041-30000-14808	360 S BURNSIDE AVE T33	90036	4	135B181   159	5509005008	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Apartment			05/04/2017 12:00:00 AM	05/08/2018 12:00:00 AM		Issued	05/08/2018 12:00:00 AM	ADDRESS	34.06834	-118.35296	Existing High-rise residential Building. Plan check for Core and shell power only Service upgrade to 4,000A 120/208V and distribution with service entrace conductors(7 sets x 1250kcmil). Existing emergency generator. Replace new panel inside each unit, use exising panel as J-box and extend to new panel. All load existing to remain. This project is in a methane zone. All series rated with attached documentation, and specifications to seal off	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12913	14041-10000-18609	25500 S VERMONT AVE	90710	15	036B197   970	7413031025	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	33.79244	-118.29048	PLANCHECK FOR T24 ENERGY. TI TO AN (E) PRE-SCHOOL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12914	18041-10000-05883	1200 S WALL ST	90015	14	124-5A209 213	5145026035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.03477	-118.25537	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 33470 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12915	18041-10001-46362	12806 W LA MAIDA ST	91607	4	168B161   379	2357017017	R1-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.15841	-118.41194	(EXPEDIATE PER APPLICENT )PC FOR ROOFMOUNTED PV SOLAR SYSTEM WITH 42 MODULES(JINKO JKM290M-60B) AND 42 OPTIMIZERS (P320 SOLAR EDGE). 1 INVERTER 10KW. NEW 225A PANEL. PV SYSTEM SIZE IS 12.180KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12916	13041-20000-22490	791 E PICO BLVD	90021	14	123A211   136	5132012042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.03167	-118.25113	New service and switchboards, loads and circuits for an existing commercial space.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12917	13041-10000-00762	849 S HUDSON AVE	90005	4	132B185   263	5090005007	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	34.05948	-118.3341	PV1, photovoltaic system for 2 story dwellin unit. total of 10.464 kw system. utilizes inverter - transformerless pvi6000 and pvi 3.6. solar panel - sunpower spr - 327ne - wht-d. two strings to ac disconnect	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12918	10041-10000-25510	16661 W VENTURA BLVD #108	91436	5	168B137   270	2259011034	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.15837	-118.49645	Ti in an existing medical office. EPC is for T24 & Emergency lights. (Complete PC may required by field inspection)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12919	14041-10000-00944	2411 W OLYMPIC BLVD 1-6	90006	1	130-5A201 110	5136003016	C2-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.05258	-118.28373	PC for energy only. TI tO (E) BANK. ATM EXTERIOR LIGHTING. Bank of America.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12920	18041-20000-21775	6322 N FALLBROOK AVE	91367	3	177B097    15	2039020012	(Q)C2-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			Reviewed by Supervisor	07/17/2018 12:00:00 AM	ADDRESS	34.18527	-118.62312	Plan check for power and energy for change of use from retail to indoor nursery newly connected load exceed 400A. Total area: 342 sq ftB#18016-20000-18680	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12921	15041-20001-04947	13700 W FOOTHILL BLVD	91342	7	222B153    63	2509014902	RA-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM			PC Approved	06/28/2017 12:00:00 AM	ADDRESS	34.30848	-118.43206	[[[6/28/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. REMOVING 800 AMP SWITCHBOARD, PANELS P1 - P5 AND CHANGES TO T24 FOR REDUCING INDOOR AND OUTDOOR LIGHTING ]]]]Plan check for power and energy. Project site is an existing commercial space. Project scope is a tenant improvement which includes a new 800-amp service, (1) 800 amp-rated switchboard, (5) 200 amp-rated panels, and associated loads. Indoor lighting area = 1,540 sq. ft. and outdoor lighting area = 18,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12922	17041-20000-26730	15535 W VINCENNES ST	91343	7	198B145    95	2656015012	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Re-Activate Permit	11/01/2019 12:00:00 AM	ADDRESS	34.24107	-118.47086	Plan check for the addition of a Tesla PowerWall to an existing PV1 PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12923	18041-10000-08043	2801 E 12TH ST	90023	14	120A221   161	5169007018	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.02161	-118.21898	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 12875 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12924	16041-10000-39503	1901 E VIOLET ST	90021	14	123A217    18	5166017010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.03272	-118.23381	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12925	10041-20000-00490	13539 W VENTURA BLVD	91423	5	165B157   668	2360007037	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.14771	-118.42832	T.I. in restuarant. This p/c is only for title 24 energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12926	17041-20000-19197	865 S FIGUEROA ST 4th Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for energy only. TI to existing office on 4th floor of high rise building. New lighting - 801sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12927	17041-20000-17780	4742 N RONMAR PL	91364	3	168A111    24	2174014021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Closed	02/23/2024 12:00:00 AM	ADDRESS	34.15634	-118.58033	PV1.  Install 9.45 kW DC roof mounted grid tied PV system.  (30) modules with (2) 5.2kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12928	17041-10001-23901	1014 N WESTERN AVE	90029	13	144B193   933	5536022012	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.08893	-118.30893	Supplemental PC for reduction in FA devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12929	18041-10000-23563	3440 W SUNSET BLVD	90026	13	144A203   252	5427026007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Issued	09/04/2018 12:00:00 AM	ADDRESS	34.08837	-118.27649	PC FOR ENERGY ONLY TO A CHANGE OF USE FROM RETAIL TO RESTAURANT/RETAIL SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 965.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12930	17041-10000-06302	7655 N WINNETKA AVE	91306	3	186B113     8	2114003173	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.20992	-118.57121	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  36550 SQ FT. ( OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
12931	15041-10000-19309	7545 N DEERING AVE	91303	3	186B105   258	2111030002	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.20723	-118.59677	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FIXTURES. TOTAL AREA 3204 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12932	14041-20001-16581	115 S LA BREA AVE	90036	5	138B181   919	5513019013	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.07306	-118.34425	Changes to an approved set of plans. Removing fixture type L530. Clouded changes only. (((Tenant improvement for retail store in (E) lowrise commercial building.  Title 24 plan check for changes to lighting system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12933	18041-30000-19836	603 E 115TH ST	90059	15	087A207   339	6072004027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	33.93021	-118.26482	Install new Fire alarm system with voice evac. (1) FACP, (79) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12934	15041-10000-36376	336 S ANDERSON ST	90033	14	127-5A219 210	5172019011	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.04375	-118.22595	Remove HID light fixtures and replace with new LED fixtures. Sq Ft = 9076	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12935	13041-10000-05365	3937 S 6TH AVE	90008	8	117B189  1537	5034007010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.01325	-118.32424	2.45 KW SOLAR INSTALLATION {10 MODULES: REC 245 PE BLK} {MICROINVERTERS: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12936	16041-20000-38539	21700 W OXNARD ST Ste 2000	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.17901	-118.60179	Existing commercial high-rise office remodel.  All new lights, all existing circuits.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12937	13041-10000-24015	22407 W SYLVAN ST	91367	3	177B101    28	2039024005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.18483	-118.61529	PV1. STANDARD PLAN. ROOF MOUNTED. CENTRAL INVERTER. SYSTEM SIZE: 8.085 KW DC.  33 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12938	15041-20000-04446	3700 S GRAMERCY PL	90018	8	120B189  1604	5042018009	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.02094	-118.31351	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.3kW. Ungrounded system.(20) EnPhase M215-IG microinverters with (20) 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12939	17041-20000-09183	11765 W LAURELCREST DR	91604	2	162B169  1055	2377003021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.13684	-118.38909	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.48 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12940	16041-20000-34970	18336 W SHERMAN WAY	91335	3	183B125   199	2125003015	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.20097	-118.53297	Plan check for power and energy. Addition/TI to laundromat. New 800 distribution and loads. New lighting (incl. emergency). 4,782sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12941	12041-20000-12340	8900 N CORBIN AVE	91324	12	195B117    43	2783025026	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.23252	-118.56211	GAS STATION AND MARKET /CAR WASH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12942	14041-10000-10951	2737 N CHADWICK CIR	90032	14	141A233   255	5217004022	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Expired	05/19/2016 12:00:00 AM	ADDRESS	34.07933	-118.17608	PV1 ROOF MOUNTED TRANSFORMERLESS STANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12943	12041-10000-10031	13007 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	11/07/2012 12:00:00 AM	ADDRESS	34.18799	-118.41633	installation of exterior luminaires for under canopy and for hardscape lighting.  plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12944	19041-10000-16953	1244 S LA BREA AVE	90019	10	129B181   280	5084027045	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.05218	-118.34385	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12945	15041-20000-00594	8525 N OAKDALE AVE	91306	3	192B113   148	2782015021	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.22535	-118.5668	PV1. ROOFMOUNTED SOLAR SYSTEM. 5KW AC. SMA 5000TL INVERTER20 SOLAR WORLD SW 275	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12946	18041-10000-27253	4900 W HOLLYWOOD BLVD	90027	13	147B197   353	5543008012	C2-1D	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Apartment			09/07/2018 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	03/08/2023 12:00:00 AM	ADDRESS	34.10153	-118.29632	NEW MIXED USE BUILDING WITH 150 UNIT APT AND RETAIL ON THE FIRST FLOOR.BUILDING PERMIT: 18010-10000-02757 (Possible Hi Rise?!?!)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12947	15041-10000-32930	12105 W WATERFRONT DR	90094	11	105B161  1199	4211010048	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	33.98095	-118.40764	CORE AND SHELL TO A  5 STORY , TYPE I OFFICE, RETAIL AND PARKING GARAGE LOCATED IN A METHANE ZONE. NEW 5000 AMP SERVICE WITH CONNECTED LOAD.  PC FOR ENERGY AND POWER, TOTAL SQ. FT. 717320.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12948	17041-20000-46469	20146 W HART ST	91306	3	183B113   466	2135033012	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.19732	-118.57284	Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.7.6kW ungrounded pv system. (23) 325W pv modules. (23) 400W power optimizers.(2) 5kW Tesla powerwall 2s.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12949	18041-10001-46440	817 S TREMAINE AVE	90005	4	132B185   162	5090001002	R1V3-RG	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.06026	-118.33622	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 44 MODULES (Q.PLUS L .G4.2 325), 22 MICROINVERTERS (CP-720-60-72-208/240-MC4). SYSTEM SIZE IS 14.30 KWdc 11.77KWAC. SCOPE INCLUDES 100A  AC COMBINER BOX SIMENS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12950	18041-20000-18948	7222 N VARNA AVE	91605	2	183B157    26	2328028030	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.20186	-118.42457	Plan check for power and energy. Project site is a new storage building with accessory office. Total lighting area = 3,100 sq. ft. (Note: Building is being powered from a new service located on a separate building on the lot. The service is under application number 18041-20000-18954. Building permit has been issued under 16010-20000-02267).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12951	18041-10001-22747	591 N IRVING BLVD	90004	4	141B189   663	5523030021		Central				1924.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/29/2018 12:00:00 AM	ADDRESS	34.08149	-118.31884	void....wrong application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12952	11041-20000-20330	6333 W 3RD ST Stall 623	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	Existing retail space.  New spice store to occupy space.  Stall number 623.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12953	18041-20000-11503	14840 W ROUND VALLEY DR	91403	4	162B149   182	2275013007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	PIN	34.14298229	-118.45464034	Plan check for a PV1 roof-mounted PV system. System size is 10.6 kWac and consists of (1) inverter, (35) modules, (2) load centers, and (2) Tesla PowerWalls.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12954	13041-10000-13268	2021 S WESTERN AVE	90018	10	126B193  1184	5073030066	[Q]C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM			PC Approved	05/21/2013 12:00:00 AM	ADDRESS	34.03805	-118.30923	TI of existing auto body shop.  New 400 A service, distribution board, subpanel, and 3 compressors.  Less than 400A newly connected load.  Overhead service drop, no underground work being performed (methane zone).  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12955	16041-10000-15828	820 S WILTON PL	90005	4	132B189   709	5092026016	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			05/05/2016 12:00:00 AM			Verifications in Progress	08/16/2016 12:00:00 AM	ADDRESS	34.0573	-118.3141	PC FOR POWER AND ENERGY. Proposed three story V-A apartment building with 1 story and 1 level basement of  I-A  parking level. 6 TYPE UNITS.(A& A1 ARE ELECTRICALY IDENTICAL ALSO B1&B, AND C1 & C). TOTAL AREA  30909 SQ FT. 2500 A SERVICEB# 15010-10000-00196-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12956	14041-20000-31862	11938 W RUNNYMEDE ST #A & B	91605	6	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.20563	-118.39354	Roof mounted PV system with optimizers.  PV system 2 of 3 size 4.25KW.Note: Zoning clearance is on 14041-20000-31858	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12957	18041-20000-29348	22408 W SOUTH SUMMIT RIDGE CIR	91311	12	198B101   220	2727022030	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.24008	-118.61499	PV1.  Install 15.4 kW roof mounted grid tied PV system.  (44) modules with (2) 7.6 kW rated string inverter.Final Permit Fees: $47.75 due Assembly Bill 1414 and California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12958	12041-20000-23988	1975 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.06159	-118.20463	T-24 lighting plan check for new and revised lighting for an INTERIOR REMODEL OF OFFICE SPACE ROOMS, 110, 314 & 422;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12959	18041-10001-35678	15452 W VISTA HAVEN PL	91403	4	159B145   124	2279020003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM			PC Approved	10/04/2018 12:00:00 AM	ADDRESS	34.13537	-118.46924	NEW ROOF MOUNTED 11.88 KW (DC) / 10.4 KW (AC) PV SYSTEM WITH 36 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12960	13041-10000-24633	2706-2708 E CESAR E CHAVEZ AVE	90033	14	127-5A225  74	5180017002	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2042.00	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.04493	-118.20391	Plan check power and energy for T.I. commercial building with music studio, banquet hall, offices and dwelling unit. New 800A service supplying building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12961	10041-10000-08541	10201 W PICO BLVD	90035	5	129B161  1442	4315019012	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM			PC Info Complete	05/07/2010 12:00:00 AM	PIN	34.05182951	-118.41257696	Ti in an existing office building. Plan check for T24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12962	15041-10000-40369	1153 S SANTEE ST 4TH FLR	90015	14	124-5A209  66	5145021028	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.03654	-118.25728	ENERGY PLAN CHECK FOR AN ALTERATIONS IN COMMERCIAL TENANT SPACES ON THE  FOURTH FLOORS; NEW LUMINAIRES AND RECEPTACLES. TOTAL AREA IS 6689 SQ-FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12963	17041-10000-36876	4222 S EDGEHILL DR	90008	10	114B185   659	5024023025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Issued	01/12/2018 12:00:00 AM	ADDRESS	34.00768	-118.33033	PC for 4.2kW rooftop solar with 11.6 kWh battery back up (Tesla powerwall covered under 17041-10002-36876). Installing new 200A panelboard.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12964	16041-10000-32043	3116 1/2 W SUNSET BLVD	90026	13	142-5A203 243	5426016007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.08477	-118.27483	PC FOR TITLE - 24 IN A MIXED USED BUILDING (2 STORIES).SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES.TOTAL AREA IS 609 SQ.FT.****************************  BUILDING         *********************CHANGE OF USE FROM GROCERY STORE TO TAKE OUT COFFEE SHOP.  HOURS OF OPERATION 7 AM - 11PM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12965	14041-10000-30552	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM			PC Info Complete	11/05/2014 12:00:00 AM	ADDRESS	34.05069	-118.24861	Energy plan check for a T.I restaurant (Eggslut Ramen).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12966	15041-20000-11656	16633 W VENTURA BLVD	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Closed	07/02/2015 12:00:00 AM	ADDRESS	34.15823	-118.49571	Title 24. Plan check for energy only. TI to existing office building. Adding new lighting. Total Sqft. 932	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12967	16041-30000-15847	709 N GARDNER ST	90046	5	141B177   590	5526012029	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.08398	-118.35336	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total indoor lighting area = 2,893 sq. ft. Total outdoor lighting area = 1,050 sq. ft.Note: Building permit has been issued under 15016-30000/30001/30002-25833.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12968	09041-20005-22007	440 S VERMONT AVE	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	01/18/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Delta 7 modifications to the approved set of plans. Changes include new 800A switchboard, new panels, new circuits, new equipment, changes to 1L1 feeder, and T-24 energy general/emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12969	12041-10000-17761	2223 S CRENSHAW BLVD	90016	10	126B185  1263	5061021036	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.03777	-118.33253	Plan check new roof mounted 13.72KW photovoltaic system for an exising single family dwelling.  Permit for PV system and, branch circuit for monitoring system, main service panel upgrade	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12970	19041-20000-01448	16243 W BERMUDA ST	91344	12	207B137   235	2680008007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.26638	-118.48624	Installation of (1) Tesla Powerwall and subpanel with critical load.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12971	14041-10000-35560	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake			2088.01	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			PC Info Complete	03/27/2015 12:00:00 AM	ADDRESS	34.06281	-118.2731	Replacement of chillers on rooftop of (E) commercial highrise medical office building.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12972	14041-10000-32361	6250 N TOPANGA CANYON BLVD Building F	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.18498	-118.60554	Power plan check for new electrical equipment related to outdoor lighting systems for common area of Westfield Topanga outdoor mall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12973	13041-20000-33609	9039 N RESEDA BLVD	91324	12	195B125    56	2770004006	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.2348	-118.53635	INSTALL 14 FLOURECENT FIXTURES, 2 EXIT SIGNS & 16 OUTLETS enegy plan check only hAIR SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12974	16041-10000-19867	1308 S HUDSON AVE	90019	10	129B185   535	5083026014	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Expired	08/13/2018 12:00:00 AM	ADDRESS	34.05078	-118.33733	PV1 rooftop solar 3.0kW AC system.   (8) Modules Triex U290   (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12975	18041-20000-28554	11254 W KAMLOOPS ST	91342	7	213B173   157	2530037003	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.28076	-118.37668	PV1.  Install 6.96 kW roof mounted grid tied PV system and energy storage system.  (24) modules with 7.6 kW rated string inverter and 9.8 kWh rated battery backup.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12976	12041-20000-11037	8100 W MCGROARTY ST	91040	2	201B193     7	2559032003	RE11-1, RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	Public Safety Only			05/14/2012 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.25233	-118.30924	Fire alarm system for day care center.  Converted residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12977	19041-20000-45165	13200 W CROWLEY ST	91331	6	195B157   817	2627024011	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.22949	-118.42008	Plan check for PV roof mounted system, PV system size: 3.0KW  with 9 PV Modules and 1 inverter(3.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12978	15041-20001-43437	4152 N ADLON PL	91436	5	165B133   416	2292006021	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.14664	-118.50613	EXPEDITER PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.8 KWac. (50) MODULES-SUNPOWER SPR-327NE-WHT-D(3)INVERTERS- SUNNYBOY SMA SB7000TL-US-22, SMA SB3800-US-22, SMA SB3000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12979	12041-10000-15301	1425 S SAN PEDRO ST	90015	14	123A209     2	5133029905	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	08/12/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.0319	-118.2549	INSTALL METHANE GAS MITIGATION SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12980	10041-10000-10376	10250 W SANTA MONICA BLVD # 112	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IMPROVEMENT IN A RETAIL STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12981	19041-10000-14439	555 W 5TH ST 38TH FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR T24 ENERGY ONLY. SCOPE INCLUDES  NEW LIGHTS AND RECETPACLES IN RESTROOMS ON THE 38TH FLOOR. TOTAL AFFECTED AREA 800SQ.FT b#19016-10000-09731	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12982	13041-10000-33427	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	33.97749	-118.41246	Installation of methane detection system with 22 devices and one panel. Phase 1, playa vista.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12983	16041-10001-20256	8500 W BEVERLY BLVD 628	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	SUPPLEMENTAL PC FOR T-24 (16041-10000-20256). CHANGES CLOUDED UNDER DELTA 3. TOTAL AREA 9158 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12984	18041-10000-34828	7080 W HOLLYWOOD BLVD	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.10134	-118.34445	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT, NEW NON LOAD PARITION WALLS, CEILING, RESTROOMS & EXTERIOR FACADE REMODELING. - TOTASL AFFECTED AREA = 6315 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12985	13041-20000-20139	2445 N DALY ST	90031	1	139-5A221 259	5204004803	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	ADDRESS	34.07502	-118.21584	Change ot lighting and loads in an existing low-rise commercial building.  New load is 200 amps per applicant (Inspector to verify) .  PLAN CHECK ONLY for ENERGY,  NO Emergency Lighting.  Permit fees are under INPSECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12986	17041-20000-01476	2211 W HILL DR	90041	14	163-5A221  76	5671002002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.143	-118.21427	pv1install roof mounted pv system sized 11.4kw interconected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12987	15041-20000-26925	17400 W VANOWEN ST	91406	6	180B129    23	2229010019	RA-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.19374	-118.51243	Installation of new fire alarm system in existing school building.  61 new devices + 1 new FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12988	15041-20001-32721	5939 N COLBATH AVE	91401	2	177B153   961	2246003021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	34.17863	-118.43674	Expedited per customer request.PV1. Install roof mounted PV system sized 3 kW. Adding to an existing system. Interconnected with main service panel.(12) Kyocera KU 265 Modules(1) ABB PVI-3.0 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12989	15041-20000-05767	800 W WILSHIRE BLVD STE 400	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.0493	-118.25841	Plan check for Title 24 only. Project site is a section of a floor within an office building. Building is high-rise. Total lighting area = 3,192 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12990	13041-20000-32864	12522 W MILBANK ST	91604	2	168B161  1111	2362028018	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.15308	-118.40603	PV1 TRANSFORMERLESS INVERTER. USING SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 7.395KW. 29 PANELS AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
12991	19041-20000-14072	17266 W CAGNEY ST	91344	12	219B133    77	2608008024	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	PIN	34.30045114	-118.51052105	INSTALLING A NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 5.31KW DC/3.8KW AC. SCOPE OF WORK INCLUDES (18) PV MODULES WITH P320 OPTIMIZERS, AND A SE3800H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
12992	18041-10000-43033	2857 W AVENUE 35	90065	1	154-5A215 262	5457026011	[Q]CM-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Issued	11/16/2018 12:00:00 AM	ADDRESS	34.11619	-118.23606	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 1063 SQFT AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12993	17041-10000-00052	601 W 5TH ST FLR 4+11	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	01/04/2023 12:00:00 AM	ADDRESS	34.05049	-118.25386	PC FOR T-24 ONLY, REMOVAL OF GREENHOUSE ADD ON TO BE CONVERTED TO EXT TERRACES W/STRUCTURAL CANOPY. SCOPE OF WORK INCLUDES NEW OUTDOOR LIGHTING. TOTAL SQ. FT. 4564.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12994	16041-10000-26437	21300 W VICTORY BLVD suite 950--955	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.18813	-118.59618	PC FOR TI. TITLE 24 ENERGY ONLY. LIGHTINIG INSTALLED ONLY. TOTAL AREA 2325 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12995	15041-10001-24056	1500 W PACIFIC COAST HWY Bldg B	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION OF 15 DEVICES,  FOR FUTURE ADA REQUIREMENT.  ((NEW FIRE ALARM FOR New 3-story, 5 unit apartment with garage, Typev VA construction. 23 FA DEVICES.CONTROL PANEL IN REC B WITH APP # 150141-10000-24054.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12996	13041-20000-08531	10250 W SANTA MONICA BLVD #56	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			Corrections Issued	09/26/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. for an existing retail space.  New lighting.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12997	13041-10001-14477	6081 W CENTER DR 113-119	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	33.97811	-118.39245	REVISIONS TO PERMITTED SET OF PLANS- RELOCATED FLOOR OUTLETS TO POWER POLES, CHANGES TO SOME LUMINAIRES BECAUSE OF ARCHITECTURAL CHANES, AND REVISED SYMBOL SCHEDULEChange of use of Howard Hughes Promenade space from retail (bookstore) to A2 and A3 occupancy (restaurant and arcade/amusement - Dave and Buster's).  New unit distribution system fed from existing service and main switchboard.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
12998	10041-10000-24625	12860 W MUSCATINE ST	91331	6	198B161   286	2629027022	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.00	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	34.23896	-118.41288	NEW T-MOBILE CELL SITE AND SERVICE UPGRADE TO 800 AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
12999	14041-20001-24843	7006 S HOOVER ST UNIT 4	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #4.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13000	18041-20000-15992	12603 W WELBY WAY	91606	2	180B161   261	2325002031	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	PIN	34.19232015	-118.40697152	Plan check for PV roof mounted sytem, System size: 7.6kW with 28 modules and 1 inverter (7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13001	13041-20001-23797	12877 N JOLETTE AVE	91344	12	222B129   151	2601045027	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.30383	-118.51462	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW AC USING 28 MODULES 2 CENTRAL INVERTERS TRANSFORMERLESS INVERTERS. POI AHEAD OF MAIN, VERIFY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13002	12041-10000-12059	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	33.97451	-118.42531	PLAN CHECK FOR NEW CORE AND SHELL FIRE ALARM SYSTEM COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13003	16041-20000-15094	19401 W LONDELIUS ST	91324	12	195B117   106	2783025052	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.22997	-118.55595	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT AND CONVERSION OF PART OF WAREHOUSE INTO OFFICE. 1701 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13004	19041-10000-15915	1642 S FAIRFAX AVE	90019	10	129B173  1414	5068024020	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.04625	-118.36779	Plan check for a 6kw AC / 7KW DC / 6.5kw CEC AC roofmounted with (1) inverter, (25) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13005	17041-10000-08844	350 S GRAND AVE FL 2-7	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	T-24, PC FOR ENERGY ONLY. RESTROOM UPGRADES ON 665 SQ FT ON EACH FLOOR AT THE 2ND, 3RD, 4TH, 5TH, 6TH, AND 7TH FLOOR. NEW TOILET PARTITIONS, LIGHTING, COUNTERTOP AND FINISHES. Total affected area  665*6 floors =3990 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13006	17041-20000-28626	631 S OLIVE ST lobby	90014	14	129A209   124	5144004032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.04749	-118.25498	ti to an existing high rise building lobby.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13007	16041-10000-30446	7900 N CLYBOURN AVE #A	91352	2	189B177   369	2466031026	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.21401	-118.36386	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.TOTAL AREA (INDOOR) 6600 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13008	18041-20000-30584	106 N WEST CHANNEL ROAD	90402	11	120B129   105	4410010020	[Q]RD1.5-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.02833	-118.51897	Plan check for Title 24 Energy only in existing space T.I. Total area; 1404 sqs ft.B#178016-20000-04546	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13009	14041-10000-14470	2670 N GRIFFIN AVE	90031	1	139-5A223  15	5206010039	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.07841	-118.21167	"PV2 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 75KWAC. 275 MODULES AND 5 INVERTERS"" $0 permit fee is due to the 2012 Senate Bill No. 1222."""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13010	14041-20000-14837	432 S CITRUS AVE	90036	4	135B185   320	5507013018	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			Corrections Issued	06/04/2014 12:00:00 AM	ADDRESS	34.06585	-118.33954	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.08KW AC USING MICROINVERTER ENPHASE M215. USING NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13011	15041-20000-11344	16648 W BRYANT ST	91343	12	195B137   899	2689021014	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.22745	-118.49571	Plan check for PV roof mounted 6kWac system. 1 inveter and 32 modules(KYOCERA KU2606XPA) and 3 strings	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13012	19041-20000-02013	10941 N CARTWRIGHT DR	91311	12	210B113   248	2708029007	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.26979	-118.56657	pv1install roof mounted pv system sized 5.7KW AC interconnected with msp. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13013	11041-10002-09329	3663 W WILSHIRE BLVD Temple	90010	10	132B193    23	5503027016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			10/02/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.06188	-118.30486	Revision to approved plans. Revise plans to include new 2000A section, new loads, light fixtures, and relocate loads. Seperate existing emergency loads and standy by loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13014	13041-10000-03830	13715 N SHABLOW AVE	91342	7	228B161   472	2580009004	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Expired	03/11/2015 12:00:00 AM	ADDRESS	34.32123	-118.41103	PV1  ROOF MOUNTED SOLAR INSTALLATION IN A SINGLE STORY HOME USING MICROINVETER STANDARD PLAN. INSTALLING 14 MODULES IN A SINGLE CIRCUIT. SYSTEM SIZE IS 3.024KW [INVETER: ENPHASE # M215-60-2LL-S22 |||| MODULES: REC # REC 245 PE]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13015	15041-20001-18115	7706 W CHANDELLE PL	90046	4	156B177   156	5570023017	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.12637	-118.36407	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (32) modules, and (1) inverter. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13016	19041-10000-44560	1248 S FAIRFAX AVE	90019	10	129B173   365	5086004019	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	34.05204	-118.3664	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13017	19041-20000-26476	1505 N EDGEMONT ST	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.09843	-118.29637	T24 PLAN CHECK OF EXISITING MEDICAL OFFICE. LIGHTS AND OUTLETS ONLY. 1 TO 1 REPLACEMENT OF POWER EQUIPMENT. TOTAL SQUARE FOOTAGE = 295 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13018	17041-20000-34461	14327 W JOY DR	91331	6	198B153  1033	2644027245	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24151	-118.44545	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13019	19041-10000-16966	13038 W SATICOY ST STE B	91605	2	186B161   442	2303022001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.20697	-118.41722	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13020	19041-20000-07704	5515 N CAHUENGA BLVD	91601	2	174B177   860	2416020023	CR-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Apartment			03/04/2019 12:00:00 AM			PC Approved	07/22/2020 12:00:00 AM	ADDRESS	34.17051	-118.36178	800A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13021	17041-30000-10253	17141 W BURTON ST	91325	6	192B133   537	2204001051	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.22028	-118.50706	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13022	18041-20000-15272	15821 W VENTURA BLVD Suite 170	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Issued	04/25/2018 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,587 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13023	15041-20001-31342	8455 N WHITE OAK AVE	91325	12	192B129   152	2787010019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.22408	-118.52	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 12 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13024	17041-10000-13975	10250 W SANTA MONICA BLVD #1075	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for TI on existing commercial space ""Century City Optometry""""  in Westfield Century City Ste. 1075.  Service and panelboard are existing."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13025	12041-10000-25333	601 W 5TH ST	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.05049	-118.25386	Title 24 on the second floor of a high rise, emergency lites on gen set.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13026	16041-20000-42951	10254 N HAINES CANYON AVE	91042	7	204B201   623	2569020057	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.25499	-118.27734	Plan check for installation of solar pv system roof-mounted on SFD. Interconnect with a 200A MSP.7.68kW ungrounded system. (32) EnPhase M250 microinverters. (32) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13027	15041-10000-16694	915 S SANTA FE AVE	90021	14	123A217   117	5166012011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.03213	-118.2302	3,927 sq. ft. single story distillery TI.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13028	18041-10000-16439	5807 W GREGORY AVE	90038	13	141B189    16	5534029015	PPSP	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.08632	-118.32254	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13029	13041-10000-18770	8126 N WINNETKA AVE	91306	3	189B113   151	2106028023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.21774	-118.57085	PV1 2 story. ROOF-MOUNTED SOLAR INSTALLATION, WITH 42 MODULES AND 2 INVERTERS, SYSTEM SIZED AT 10.29KW. ALSO WILL BE UPGRADING 225A MSP.  DC-UNGROUNDED. MODULE# INGLI ENERGY YL245P-29B 245W, INVERTER # POWER-ONE-PM-3000-OUTD AND POWER-ONE-PM-6000-OUTD . AND SERVICE UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13030	16041-10003-45686	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			PC Approved	09/27/2019 12:00:00 AM	ADDRESS	34.01303	-118.24279	PLAN CHECK ONLY. Change to approved set  Total PV2 system 1.33MW with (3420) modules using p850 optimizers, and (11) using (se10k & se33.3k)inverters interconnecting through a 1600 Amps service panel. CHANGES NOTED UNDER DELTA #10 and #11Change includes relocating point of interconnection from transformer tap to switchgear line side tap.original scope: (((PV2.  Install 1.68 MW roof mounted grid tied PV system.  (5309) modules with (21) 80 kW rated central inverters.  Frameless modules.  Feed-in-tariff project.original pc #: 16041-10002-45686original pc #: 16041-20000-45686Note: $0.00 permit fee due to CA Senate Bill 1222)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13031	10041-10000-22525	613 S GAYLEY AVE	90024	5	135B149   241	4363006020	[Q]R4-1VL	West Los Angeles	Westwood			2653.05	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.06762	-118.44862	Fraternity house (23 bedrooms) over parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13032	10041-20000-07181	941 W 37TH PL 1st Floor	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	09/02/2010 12:00:00 AM	ADDRESS	34.01943	-118.2897	Plan check T-24 Energy (general/emergency) lighting for computer lab renovations at USC Salvatori Computer Science Center (1st floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13033	16041-10000-36491	8633 S CIMARRON ST	90047	8	096A191    24	6036001009	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	33.95892	-118.31623	PC for rooftop PV consisting of 20 photovoltaic modules and one 6.6 KW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13034	15041-10000-19418	4357 W WILSHIRE BLVD	90010	4	132B189    16	5505022013	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.06198	-118.32315	CHANGE OF USE FROM MASONIC LODGE TO NON-PROFIT MUSEUM.  TI TO EXISTING BUILDING NEW 2000 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.BUILDING APPLICATION UNDER 14016-10000-13466.FIRE VARIANCE ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13035	10041-10000-23891	1201 S FIGUEROA ST	90015	9	127-5A205 516	5138016914	PF-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.04202	-118.26715	New fire alarm system. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13036	19041-10000-43436	700 S FLOWER ST 1120,1140-1160	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.04835	-118.25882	Energy plan check for a T.I. Scope includes new lighting and equipment with a total lighting area of 7,872-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13037	12041-10000-20571	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.04804	-118.46227	Lighting change to an existing 10th floor elevator lobby and corridor.  Load change is less than 400 Amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13038	16041-10001-44344	12919 S FIGUEROA ST	90248	15	081B201   311	6132003023	M2-1VL-O, P-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	33.91455	-118.28296	PC FOR REVISIONS TO APPROVED SET. CHANGES UNDER DELTA B68. SCOPE INCULDES ADDITION OF 75KVA XFMR, NEW PANEL WITH CIRCUITS AND NEW COMPRESOR.B#16014-10000-05897	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13039	15041-10000-00080	8100 W BEVERLY BLVD	90048	5	138B177   481	5511005019	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM			PC Info Complete	01/02/2015 12:00:00 AM	ADDRESS	34.07593	-118.36602	Plan check for Title 24 only. Project is the showroom for a commercial building. Total lighting area = 6,760 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13040	17041-20002-30960	24008 W SCHOENBORN ST	91304	12	192B089   147	2017037015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.22101	-118.64926	11/28/2017 Changes to an approved set of plans. Changes have been made to the PV module manufacturer and model, string configuration, and PV module roof layout. All changes have been clouded.*****Previous Work Description*****PV1.  Install 8.54 kW roof mounted grid tied PV system.  (28) modules with 7.6 kW rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13041	12041-20000-15973	24532 W STARLIGHT LANE	91307	3	186B089   529	2031014034	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.20452	-118.65709	Roof mounted P.V. system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13042	12041-10000-06046	5555 W WILSHIRE BLVD	90036	4	135B181   895	5508012038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	06/22/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.0625	-118.34962	TI for smart and final, new circuits and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13043	19041-20001-12698	17966 W LAKE VISTA DR	91316	5	162B125   185	2184048003	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.1415	-118.52572	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO ROOF PLAN LAYOUT, EQUIPMENT LAYOUT,  AND SINGLE LINE DIAGRAM PV STRING DISTRIBUTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13044	18041-10000-16453	10169 N TUJUNGA CANYON BLVD	91042	7	202-5A199 135	2568011001	M1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.25021	-118.28929	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13045	18041-10000-30169	10408 N BALBOA BLVD	91344	12	204B133    17	2684012038	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.25952	-118.50211	Plan check for T24 only, install outdoor lighting on the canopy.Total area under the scope: 3,128 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13046	15041-10000-30457	242 S ANDERSON ST	90033	14	127-5A219  67	5172010004	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Expired	11/01/2017 12:00:00 AM	ADDRESS	34.04491	-118.22645	Energy plan check for a studio showroom; Scope includes new lighting, receptacles and equipment; total area is 11613-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13047	14041-20000-19946	1028 N SEWARD ST	90038	13	144B185   846	5533012021	MR1-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.08983	-118.33299	Plan check for power and energy on a new commercial building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13048	14041-20000-17766	1816 N VERMONT AVE	90027	4	150B197  1082	5590020002	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Reviewed by Supervisor	08/22/2014 12:00:00 AM	ADDRESS	34.10411	-118.29162	T.I. to a restuarant.  New 1600A service, panel, branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13049	15041-20001-10220	19131 W VICTORY BLVD BLDG 7	91335	3	180B121   532	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM			PC Approved	04/29/2015 12:00:00 AM	ADDRESS	34.18674	-118.55038	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. TWO MIRRORED BUILDINGS ONE ADDRESS.  (1 OF 2 BUILDING 7 ONLY )  SYSTEM SIZE: 7KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13050	16041-20001-40404	3332 E GRANADA ST	90065	1	147A219   214	5454027034	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.09704	-118.22661	RSES expedited plan check fee.  (((PV1.  Inspire 2.616 kW DC roof-mounted grid-tied PV system.  (8) modules with (1) 3.0 kW rated central inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13051	19041-10000-10261	3030 W 8TH ST #100	90005	10	132B197   465	5094012029	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.0576	-118.29246	REPLACE INDOOR FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13052	17041-10000-37912	300 S LINCOLN BLVD	90291	11	111B145   611	4243016021	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Issued	12/20/2017 12:00:00 AM	ADDRESS	34.00138	-118.46746	TITLE 24 PLAN CHECK FOR INDOOR/OUTDOOR LIGHTING - TI- REMODEL OF EXISTING CONVENIENCE STORE & ADD 492 SF- TOTAL AFFECTED AREA = 10400SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13053	13041-20000-32413	2006 N ALMADALE AVE	90032	14	136-5A229 209	5215012019	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.06688	-118.19164	PV1 MICROINVERTER STANDARD PLAN. Total system size 3.45KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13054	15041-20001-14765	12550 W OTSEGO ST	91607	2	171B161   804	2357007002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM			PC Approved	07/17/2015 12:00:00 AM	ADDRESS	34.16303	-118.40689	07/17/2015 Changes to an approved set of plans. Changes have been made to the amount of modules per PV source circuit. Number of total modules of the system has remained the same.*****Previous Work Description*****Installation of new roof mounted solar PV array.  Total system size = 9.8 kWac.  Two central inverters are used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13055	19041-20001-25822	5315 N WILKINSON AVE UNIT   4	91607	2	171B165   226	2347031***	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.16718	-118.4043	Plan check for apartment PV. Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a multifamily dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13056	18041-20000-23330	6440 N WILBUR AVE 1st Floor	91335	3	180B121   391	2127001014	RA-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.18797	-118.54453	Plan check for Title 24 only in existing space, expansion of existing dining area on the 1st Floor. Total area: 393 sq ft. B#18016-20000-13523	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13057	10041-10000-23926	11430 W WOODBINE ST	90066	11	117B157   202	4249002900	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM			Corrections Issued	12/01/2010 12:00:00 AM	ADDRESS	34.018	-118.42896	T24 only plan check for interior and for exterior lighting systems. Emergency lighting was not reviewed, but may be required.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13058	12041-10000-26514	1455 N SUTHERLAND ST	90026	13	139-5A211  26	5406006001	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.07807	-118.25173	INSTALL A 5.52KW PHOTOVOLTAIC SYSTEM ON ROOF OF SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13059	13041-10000-18283	8021 S VICKSBURG AVE	90045	11	099B165   826	4107003029	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	ADDRESS	33.96546	-118.39452	New roof mounted PV system, 2.45KW. Transformerless inverter and module equiped with optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13060	16041-20000-00688	17840 W BESSEMER ST	91335	5	177B129   388	2123031006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	PIN	34.18073797	-118.52190672	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (16) micro-inverters and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13061	15041-20000-18967	7034 N BALBOA BLVD	91406	6	183B133   445	2225020027	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Expired	07/12/2017 12:00:00 AM	ADDRESS	34.19844	-118.50092	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13062	12041-20000-24240	18452 W HALSTED ST	91325	12	201B125   404	2764008001	(T)(Q)R3-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.24439	-118.53563	New 47 unit apartment. Variance is being submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13063	17041-10000-15686	150 W 12TH ST	90015	14	126A207   234	5139025028	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.03831	-118.26077	T24 ONLY. REPLACE EXISTING HID LIGHT FIXTLURES WITH NEW LED LIGHT FIXTURES. TOTAL ARE  A  17800 SQ FT. INDOOR  LLIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13064	15041-10000-02964	4601 S WILTON PL	90062	8	111B189   600	5015017018	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.00171	-118.31506	PV1 STANDARD PLAN RESIDENTIAL. 9 MODULES AND 1 INVERTER. 3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13065	16041-10002-42610	695 S SANTA FE AVE	90021	14	124-5A2171363	5164019026	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	09/04/2020 12:00:00 AM	ADDRESS	34.03508	-118.23039	CHANGES TO AN APPROVED SET OF PLANS. CHANGES ARE UNDER BULLETIN 007 AND DELTA 1 & DELTA S. CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM, ADDING NEW PANELBOARDS, SERVICE LOAD CALCULATIONS, REVISING POWER AND LIGHTING FLOOR PLANS. ALSO, REVISING TITLE 24  CALCULATIONS, AND RELOCATING CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13066	16041-10000-20243	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.06338	-118.20434	PLAN CHECK FOR POWER ONLY.  UPGRADE CHILLER AT BASEMENT LEVEL-1.  NEW CHILLER IS RATED FOR 641 A @ 480/277 V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13067	16041-10000-29920	901 E NEW DOCK ST	90731	15	024B209   295	7440020908	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Issued	01/19/2017 12:00:00 AM	ADDRESS	33.7552	-118.25713	PC FOR 2400V CABLE TO CRANE CONNECTION. CRANE POWER WILL PICK UP AT THIS LOCATION. CHECKING FOR SHORT CIRCUITS AND LOADING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13068	15041-20000-10326	17520 W SUNBURST ST	91325	12	195B129    77	2768025006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	34.23444	-118.51664	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, and (22) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13069	19041-10000-21600	6938 N DEERING AVE	91303	3	183B105   723	2138016008	MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Issued	06/07/2019 12:00:00 AM	ADDRESS	34.19686	-118.59649	Remove HID fixtures and replace with new LED fixtures (Indoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13070	16041-20000-43082	16255 W VENTURA BLVD 2nd & 4th-Fl Corr.	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.15711	-118.48768	Plan check for energy only. TI to 2nd and 4th floor corridors of high rise building. New lighting (incl. emergency). 1,871sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13071	13041-10000-34695	4000 N ROGEN DR	91436	5	165B137   592	2291013032	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.1442	-118.49638	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH 200A MAIN.SYSTEM SIZE IS 8.50 kW. MICROINVERTER SYSTEM ON NON-STANDARD PLAN, WITH 34 MODULES, 34 ENPHASE M215-60-2LL-S2x. ALSO INSTALLING NEW 100A RATED SOLAR LOAD CENTER.MODULE: CANADIAN SOLAR CS6P-250P	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13072	14041-10000-08234	6255 W SUNSET BLVD # 120	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR ENERGY ONLY FOR ONE MAIN FINANCIAL. PERMIT HAS ALREADY BEEN PULLED UNDER APPLICATION: 14041-10000-07206	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13073	17041-20001-44064	20441 W KESWICK ST	91306	3	186B109    40	2114001031	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.20979	-118.57883	expeditepv1install roof mounted pv system sized 12kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13074	11041-10000-13978	1000 W TEMPLE ST 3rd floor	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles, Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM			PC Approved	07/06/2011 12:00:00 AM	ADDRESS	34.06171	-118.25046	T.I. on the third floor of a high rise building.  Building a new training room within the existing open office space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13075	14041-20000-27785	1561 S REEVES ST	90035	5	129B165   421	4306013023	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.05072	-118.39661	STANDARD PLAN MICROINVERTERS 7.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13076	17041-10000-44404	811 S CURSON AVE	90036	4	132B177   243	5089014033	R2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.06036	-118.35598	PC for 7.6kW roofmounted PV system. Installing 20 modules with optimizers and one 7.6kW solaredge central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13077	16041-20003-10878	21627 W DEVONSHIRE ST	91311	12	204B105   216	2722009005	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.2574	-118.60127	3/15/2018original approved set of plans lost.Plan check for power and energy.  this is plan check only.  permit fees paid under master application 16041-10000-10878 and supplemetal 16041-20001-10878	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13078	12041-10002-02898	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM			PC Approved	04/12/2012 12:00:00 AM	ADDRESS	34.0446	-118.21143	Plan check only. Revision to approved plans. Revise to main switchboard 42KAIC to 35KAIC. LADWP AFC including motor load contribution is 34KAIC.  Panel A and Panel B length revise from 30ft  to 50ft. AFC Panel A is approximately 21.1KAIC and Panel B is 18KAIC. Panel A and B shall be suitable for fault current.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13079	15041-10000-22208	11143 W ALLEGHENY ST	91352	7	201B173    67	2538027022	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.25089	-118.37447	pv1install roof mounted pv system sized 3.8kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13080	13041-20001-26677	4501 N PORTICO PL	91316	5	165B133    29	2289032013	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.15244	-118.50698	((EXPEDITE FEES))PV1 TRANSFORMED SYSTEM. TOTAL SYSTEM SIZE 17.331 KW. 53 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13081	16041-20000-04198	6244 N ELMER AVE	91606	2	177B173   215	2336025003	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.18446	-118.37673	PV1.  Install 5 kW AC roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13082	19041-10000-16167	7064 W GREELEY ST	91042	7	202-5A201 394	2568016045	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.20	Electrical	Electrical	Apartment			05/02/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	07/16/2021 12:00:00 AM	ADDRESS	34.24885	-118.28542	FULL PLAN CHECK FOR NEW 3-STORY 9 UNIT APARTMENT 20,965 SQ.FT. 2 LEVELS OF RESIDENTIAL UNITS. TOTAL AREA APPROX. 8,605 SQ.FT. (1) DELTA SYSTEM 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13083	19041-10000-15030	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	06/26/2020 12:00:00 AM	ADDRESS	34.25776	-118.46707	Power plan check for a core/shell tenant improvement. Scope includes a new distribution panel and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13084	14041-20001-02334	16430 W TUPPER ST	91343	12	198B137   571	2676025006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/18/2014 12:00:00 AM	ADDRESS	34.23922	-118.49054	changes to approved set. plan check only. changes to roof and equipment layout. PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC. USING SOLAR OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13085	11041-20000-05918	17777 W VENTURA BLVD #101	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM	03/25/2011 12:00:00 AM		Permit Finaled	09/27/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	restaurant # 101 TI includes outdoor energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13086	13041-10000-36195	511 E 11TH ST	90015	14	124-5A211  54	5145019020	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.03638	-118.2537	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13087	14041-10001-30377	11460 N DORAL AVE	91326	12	213B121   440	2822031025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			PC Approved	12/02/2014 12:00:00 AM	ADDRESS	34.28009	-118.54884	((((Expedited per applicants request))))6.54kW DC roof mounted PV1 system. System consists of (20) 327 W modules and (1) 6000 W rated (transfomer-less) inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13088	17041-20000-23727	8250 N LAUREL CANYON BLVD	91605	6	192B165   565	2310001032	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.22107	-118.39632	Plan check for energy only. TI to restaurant (Taco Bell). New lighting - indoor=1,401sqft.this is plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13089	10041-10000-23534	800 W 6TH ST	90017	9	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.05011	-118.2577	Ti in an existing office. EPC is for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13090	16041-10000-41145	9400 N BURNET AVE	91343	7	198B145    64	2656021***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	PIN	34.24227928	-118.46180174	ROOF MOUNTED PV SYSTEM TOTAL OF 14 MODULES AND CENTRAL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13091	12041-10000-04099	333 S LOS ANGELES ST	90013	9	129A213   149	5148001006	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Public Safety Only			02/23/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	09/25/2012 12:00:00 AM	ADDRESS	34.04788	-118.24566	New fire alarm system for a 4 story commercial BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13092	17041-10000-08950	10250 W SANTA MONICA BLVD STE 2625	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for first time tenant ""Fossil"" ste. 2625, 784 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13093	19041-10001-09803	19350 W NORDHOFF WAY STE F	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	34.23523	-118.55518	CHANGE TO AN APPROVED SET, CHANGE UNDER DELTA-R1 & PC2. CHANGES TO POWER & ENERGY. Changes include removing RTU and adding a heat pump. Revising load calculations, revising floor plans, and updating title 24 calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13094	16041-10002-38452	201 S BROADWAY STE 306	90012	14	130-5A213  21	5149009019	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Approved	04/07/2017 12:00:00 AM	ADDRESS	34.05237	-118.24698	Change to approved set  by adding a fixture and connect emergy lighting to emergency source. All changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13095	18041-10000-37008	9500 N EL DORADO AVE	91352	6	198B165     4	2629006005	MR2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.24142	-118.39897	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13096	12041-20003-27943	1901 1/2- S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	34.03435	-118.45789	Change to approve set of plan(Plan check only). Changes apply to delta 10 only(Emergency lighting circuit in the stairwells connect to existing inverter circuit)((((((((((CUSTOMER BROUGHT CHECK. PLEASE RECALCULATE FEES BEFORE FINAL APPROVAL. NEW SERVICE? separate fire alarm variance filed 6/17/2013 mtNEW PARKING GARAGE. FULL POWER AND ENERGY PLAN CHECK. new parking facility. 833 car. 5 and half tier.  68621 sf below and 187934 sf above grade. 981 sf of attached restrooms and lockers. total SF = 257536 SF))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13097	18041-10001-08912	17516 W RAYMER ST	91325	12	192B129    81	2787024009	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.22601	-118.51651	PC FOR CHANGES TO APPROVED SET.  CHANGES MARKED UNDER DELTA 1. SCOPE INCLUDES REVISION TO ROOF MODULES LAYOUT. TOTAL MODULE COUNT REMAIN THE SAME.  THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13098	16041-20000-13597	5425 N SEPULVEDA BLVD	91411	4	172-5A145   7	2250001022	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			04/19/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.16914	-118.4664	Plan check for a PV2 roof-mounted PV system. System size is 17 kWac and consists of (3) inverters, (76) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13099	17041-10000-17028	6600 N TOPANGA CANYON BLVD 1102	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Title 24 plan check.  Replace existing lighting with LED in retail space.  Total area = 1,077 sq. ft.       Building permit #17016-10000-13455	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13100	19041-20000-33943	14557 W VANOWEN ST	91405	6	183B149   737	2219025033	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Issued	08/28/2019 12:00:00 AM	ADDRESS	34.19407	-118.45072	Plan check for Title 24  on existing Sign lighting. Internally illuminated sign. Total illuminated area: 96 sq f.t	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13101	17041-10000-40324	1662 W PACIFIC COAST HWY	90710	15	033B193    59	7411004017	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	33.78922	-118.30629	PLAN CHECK FOR POWER IN AN EXISTING CAR WASH, NEW CONNECTED LOAD GREATER THAN 400A. SCOPE INCLUDES NEW PANEL, MCC,  EQUIPMENT AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13102	14041-10001-08786	970 N MONUMENT ST # 201	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.04646	-118.52393	(((4/4/2014- CHANGES MADE TO APPROVED SET. REVISED SOME LIGHTING. T24 CALCULATIONS TO BE VERIFIED))))TI FOR EXISTING NAIL SALON. EXPANDING NAIL SALON INTO UNIT 203. NEW LOAD DOES NOT EXCEED 400AMPS. PLAN CHECK IS FOR ENERGY CALCULATION ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13103	19041-20000-23655	5128 N LANKERSHIM BLVD	91601	2	171B173   797	2353007015	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.16378	-118.37377	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.this is plan check only.  permit fees paid under application number 19041-20000-06489	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13104	16041-20000-22239	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	Phases I and II of North Wing Renovation project of (E) school.  Temporary distribution for future construction and temporary classrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13105	17041-10000-31460	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM			Verifications in Progress	09/20/2017 12:00:00 AM	ADDRESS	34.07417	-118.26931	Power plan check for rerouting the fire pump from a demo service to an existing service.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13106	14041-20001-12088	6909 N YOLANDA AVE	91335	3	183B121   815	2126018007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.19598	-118.54053	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 6.75kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(27) Canadian Solar #CS6P-250PX pv modules(27) power optimizers 300W]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13107	10041-20000-25083	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM			PC Info Complete	12/16/2010 12:00:00 AM	ADDRESS	34.20103	-118.38536	Install branch circuits for AC units and outlets in server room of 2nd floor and on roof.  Per applicant, electrical plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13108	12041-10000-11231	700 S FLOWER ST	90017	9	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	ADDRESS	34.04835	-118.25882	remodeling of existing office space # 3380    plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13109	12041-20000-09495	19307 W SATICOY ST	91335	3	186B117  1034	2116014019	QC2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	06/06/2012 12:00:00 AM	ADDRESS	34.20851	-118.55435	MARKET T.I. OF 45,200 SQ FT.ENERGY, EMERGENCY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13110	19041-20000-31485	10318 N SEPULVEDA BLVD	91345	7	204B145   250	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	08/02/2020 12:00:00 AM	ADDRESS	34.25786	-118.46706	Power and lighting for (E) shell space for medical care facility.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13111	13041-20000-12549	14006 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	Change of use from retail to beauty salon.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13112	16041-20000-44214	21720 W VICTORY BLVD	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.18733	-118.60234	Plan check for Title 24 only. Project site is an existing commercial building/parking structure. Project scope is the lighting for a new outdoor escalator. Total lighting area = 2,239 sq. ft.Note: Building application has been created under 16014-20000-05986	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13113	18041-20000-26106	19817 W RINALDI ST	91326	12	213B113   308	2701040043	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	PIN	34.2768008	-118.56487771	Plan check for new fire alarm system for Burlington. Total new fire alarm devices: 45 devices and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13114	19041-20000-26311	3014 N WORTHEN AVE	90039	13	151-5A211 274	5437029023	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.10764	-118.25154	Commercial office TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13115	11041-10000-26777	705 W 34TH ST	90089	8	120A201   206	5123023024	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	06/01/2012 12:00:00 AM	PIN	34.02214675	-118.28186522	New fire alarm for an existing building.  1 Fire alarm panel with 147 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13116	19041-20001-34467	10993 W BLUFFSIDE DR PV 1	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.14191	-118.36968	PV2 BUILDING #2 (N) 18.4 KW AC/20.52 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (57) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13117	19041-20000-37769	12000-12004 W VOSE ST	91605	2	183B165   203	2321008015	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM			PC Info Complete	02/12/2020 12:00:00 AM	ADDRESS	34.19833	-118.39435	Plan check for power only. Scope includes a new 1200A Service suppling addresses: 12000 and 12004 Vose St.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13118	13041-10001-16236	37 E WASHINGTON BLVD	90291	11	105A145   428	4226023015	C4-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	PIN	33.97981798	-118.4659699	CHANGES TO APPROVED SET OF PLANS. ( ADD OF METHANE MITIGATION AND FEW LIGTHING AND CHANGE IN FLOOR LAYOUT) SUMMARY OF CHANGES WITH MITIGATION REPORT ATTACHED.ORIGINAL PC: TENANT IMPROVEMENT OF AN EXISTING SPACE. INSTALLATION OF A NEW 600 A SWITCHGEAR. RESTAURANT WORK.  methane zone. pc for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13119	10041-20000-25719	4600 W SPERRY ST	90039	4	165B201   177	5593007004	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Closed	07/06/2012 12:00:00 AM	ADDRESS	34.14823	-118.27596	New roof mounted P.V. system for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13120	15041-10000-00058	5253 N VANTAGE AVE 1-18	91607	2	171B165   358	2347020001	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Closed	09/06/2016 12:00:00 AM	ADDRESS	34.16639	-118.3984	Plan check for power and energy. Project is a new 4-story, 18-unit apt building. Installation of a new 1200-amp service. Total lighting area = 17,000 sq. ft. Area to be verified once T-24 sheets have been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13121	12041-10000-24952	14545 W ERWIN ST	91411	6	178-5A151 211	2241012027	[Q]C1.5-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.18376	-118.45033	NEW FIRE ALARM SYSTEM IN A 2 STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13122	16041-10000-29084	818 W 7TH ST	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.04895	-118.25943	Replace fire alarm panel.  All other devices to remain existing.  Battery calculations updated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13123	15041-20002-36375	10420 N SEPULVEDA BLVD BLDG 2	91345	7	204B145    23	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Closed	02/06/2018 12:00:00 AM	ADDRESS	34.25976	-118.46706	7/11/17changes to an approved set of plans.  changes noted delta EV only.  adding panel 2EVB and circuits.Revisions to approved set of plans.  Value engineering changes and gear orientation revision.  Approval for clouded changes delta-J only.  (((NEW TWO FLOOR MULTI USE BUILDING. CORE AND SHELL ONLY.  PLAN CHECK FOR POWER AND ENERGY.BUILDING APLLICATION# 15010-10000-03863)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13124	16041-20000-29209	20020 W BLYTHE ST	91306	3	189B113  1441	2106003134	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.21466	-118.56927	Install a roof mounted solar array on a SFD. Interconnect with a 225A MSP. 5kW ungrounded system. (22) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13125	15041-10001-27859	9600 N LURLINE AVE	91311	12	201B109   290	2748040027	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	34.24455	-118.58404	Expedited per customer request. (((PV2. installation of a roof mounted solar system for a commercial site. (2) inverters: 58.04 KW, (108) solar modules. (1) load center of 100 A.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13126	14041-10000-25008	10800 W ROSE AVE	90034	5	120B161   624	4254022035	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Expired	02/22/2017 12:00:00 AM	ADDRESS	34.02542	-118.41571	PV2, INSTALL 16830 W DC ROOF-MOUNTED SOLAR ARRAY ON A APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL.(66) MODULES: CANADIAN SOLAR CS6P-255P(2) INVERTER: SMA AMERICA SB7000US-12	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13127	16041-10003-36743	447 S HEWITT ST	90013	14	127-5A215 356	5163022017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.04216	-118.23526	PC for changes to approved set. UPDATING dimming panel layout WITH CIRCUIT CALLOUT AND lighting FIXTURES. Installing new AV receptalce and removing skillet equipment. All changes clouded under delta 10.THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13128	15041-20000-00878	501 S SHATTO PL	90020	13	135B197   762	5077003032	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.06509	-118.29014	Transfer of loads from normal to emergency. No change in lighting design only change in emergency source. Fixtures now on emergency. Photometrics provided. Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13129	16041-10000-36112	2049 S CENTURY PARK EAST 3050	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13130	16041-20000-34818	1920 W 42ND ST	90062	8	114B189  1129	5022012038	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.00715	-118.31455	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13131	16041-20000-28641	6320 N CANOGA AVE Suite 940-950	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,838 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13132	12041-10000-25415	5570 S LINCOLN BLVD	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2673.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	33.97271	-118.43031	"TI in a La Fitness Bldg. Addition of 1 new  structure, outdoor restroom & storage. Add a new panel ""PE"".  EPC is for power & energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13133	15041-20001-02769	12484 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13134	16041-10000-01829	13526 W POLK ST	91342	7	231B157   289	2582013030	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.32683	-118.4294	PV1, rooftop solar installation 4.5 kW AC system(18) SW 285 Mono(18) Enphase M250-60-2LL(1) 125A load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13135	13041-10000-20111	3627-3637 S HUGHES AVE UNIT1---27	90034	5	120B165   428	4313008006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			07/29/2013 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.02695	-118.40178	New 4-stories apartment building ;Variance is required to separate the FA PLANSNeed to add fee for Title 24 review	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13136	18041-10001-17420	240 N ROCKINGHAM AVE	90049	11	132B137   204	4406008001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM			PC Approved	05/29/2019 12:00:00 AM	ADDRESS	34.05974	-118.49126	"DELTA ""3"" CHANGES TO APPROVED PLANS FOR CHANGING THE SIZE OF CONDUTS AND MOVING PANEL ""DP"".<<<Plan check for power only. Project site is a new 2-story single-family dwelling. Work includes a new 800-amp service. Plan check only Electrical permit pulled under Building # 15010-30000-04622Note: Building application has been generated under 15010-30000-04622>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13137	12041-10000-13471	7639 W DAY ST 1-3	91042	2	204A197   186	2558034033	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Apartment			06/11/2012 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.25464	-118.29919	Plan check for power and energy. 46 unit apartment. Fire alarm variance will be filed later. 8622 indoor, 25619 outdoor sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13138	18041-20002-40068	245 N TOYOPA DR	90272	11	123B129   686	4411024027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.03161	-118.52	Revision to approved set of plans.  SLD updated to show MSP upgrade; equipment locations revised. $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.(((Plan check for a PV1 roof-mounted PV system. System size is 13.2 kWdc/10.56 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (40) modules.Fees $51.07 Due to California Senate Bill 1222 And AB 1414)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13139	12041-20000-14908	21025 W OSBORNE ST	91304	3	195B105    42	2779048008	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Info Complete	06/27/2012 12:00:00 AM	ADDRESS	34.23318	-118.59167	T.I. to existing space.  Install general lighting inside the clean room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13140	13041-10000-19811	11941 N MALLOT PL	91344	12	216B137   305	2609007012	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.2876	-118.49595	INSTALLING ROOF MOUNTED SOLAR ARRAY, INERCONNECT WITH MAIN PANEL. SYSTEM SIZE :10.045 KW. 2 STORY. TRANSFORMERLESS DC UNGROUNDED. 2 INVERTERS: POWER-ONE # AURORA PVI-6000 (6000W) AND POWER-ONE # AURORA PVI-3.0 (3000W), 41 MODULES: TRINA SOLAR # TSM-245 (245 W)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13141	12041-10007-14793	220 E 2ND ST 1-104	90012	9	130-5A213 203	5161024014	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			12/07/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.04978	-118.2429	Change to approved set by swapping (5) light fixtures in the first floor corridor with same wattage under the clouded area only, (3) key notes also being removed from the plan.(((PROPOSED MIXED USE PROJECT: 104 UNIT APARTMENTON FLOORS 2 TO 6 (TYPE IIIA), RETAIL AND OFFICE  ON THE 1ST FLOOR (TYPE I), PARKING ON 2 BASEMENT LEVELS AND 1ST FLOOR (TYPE I). SPRINKLERS USED FOR A STORY INCREASEneeds to file modivication to separate the fa plans. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13142	14041-10001-17424	5916 N FIGUEROA ST	90042	1	151-5A229 114	5492015008	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.1106	-118.19037	changes to an Approved set note changes in delta 1. ((NEW SERVIICE AND HOUSE PANEL FOR VACATED TENANT SPACES)_))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13143	19041-20000-52437	315 S 4TH AVE	90291	11	111B141   532	4286006034	[T][Q]CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	02/11/2021 12:00:00 AM		Issued	02/11/2021 12:00:00 AM	ADDRESS	33.99712	-118.4749	PV3.  Install 239.2 kW roof mounted PV system.  (598) modules with (2) 33.3 kW and (6) 20 kW rated inverters.Permit fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13144	17041-20001-34178	14317 W JOY DR	91331	6	198B153  1028	2644027240	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24171	-118.4451	Changes to an approved set of plans. Equipment ratings have changed and PV system size is now 3.8 kWac.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13145	19041-30000-28247	10608 W SANTA MONICA BLVD 1-28	90025	5	129B157   123	4321003035	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	11/20/2020 12:00:00 AM	ADDRESS	34.05329	-118.42955	INSTALL (117) NEW FIRE ALARM DEVICE ANN (1) FIRE ALARM PANEL FOR 28 UNIT 6 STORY APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13146	14041-10000-09291	8375 N LAUREL CANYON BLVD	91352	6	192B165   307	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.22391	-118.39926	TI TO AN EXISTING RESTAURANT. PLAN CHECK IS FOR POWER AND ENERGY. NEW CIRCUITS AND 1 NEW PANEL. TOTAL SQRFT 16657	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13147	19041-10001-03855	920 W BLOOM WALK	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	11/25/2020 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	34.01996	-118.28938	Change to an approved set by adding and relocating ckts on the plan. Load calculation being updated. All changes under delta-1 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13148	16041-10000-09994	5125 W HOLLYWOOD BLVD	90027	13	148-5A195  85	5544012042	C2-1D	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.10189	-118.30145	new luminaires and circuits in existing beer/wine barplan chk s for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13149	17041-10000-10452	557 N MARIPOSA AVE	90004	13	141B197   883	5520011033	[Q]R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Apartment			03/31/2017 12:00:00 AM			Reviewed by Supervisor	05/05/2017 12:00:00 AM	ADDRESS	34.0807	-118.29952	Plan check for power and energy 12 units appartments building. Total area: 9,577 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13150	14041-10000-30780	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	PIN	34.05243427	-118.25124731	Engergy plan check for office T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13151	12041-20000-07584	17161 W PARTHENIA ST	91325	12	195B133   414	2690014003	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2012 12:00:00 AM	05/15/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.22867	-118.50774	Roof mounted  14.4KW PV systems.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13152	19041-10001-10319	206 E 24TH ST	90011	9	121-5A207 262	5127033021	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.02585	-118.26623	Expedite tp PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13153	19041-20000-53385	2915 W EXPOSITION PL Unit #5	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM				NEW ROOF MOUNTED 2.56KW PV SYSTEM WITH 8 @ 320W PANELS AND A CENTRAL INVERTERS ON AN APARTMENT BUILDING FOR UNIT #5.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13154	13041-10000-22746	1734 E 41ST ST	90058	9	114A213    88	5116029006	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.00788	-118.24202	TITLE-24 PLAN CHECK FOR 7000 SF.  IN COOLER AND FREEZER AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13155	11041-20000-14192	650 S HILL ST # 714	90014	14	129A211   215	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.04623	-118.25392	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13156	15041-20000-30957	12814 W MIRANDA ST	91607	2	174B161   235	2341020003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.17496	-118.41247	PV1. ROOFMOUNTED STANDARD PLAN. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13157	19041-20000-29049	405 N ALVARADO ST	90026	13	138A205   299	5157016029	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.10	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	03/10/2020 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.07065	-118.26798	Plan check for Title 24 energy only in existing space Tenant improvement. Total area: 855 sq ft. B#19016-2000-22781	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13158	15041-20000-33607	19953 W RINALDI ST	91326	12	210B113   187	2701040018	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM			PC Info Complete	10/20/2015 12:00:00 AM	ADDRESS	34.2758	-118.56956	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW EXTERIOR LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 208.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13159	19041-20000-15332	8815 N QUAKERTOWN AVE	91324	12	195B113   263	2782032013	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.23055	-118.56991	PLAN CHECK FOR THE ADDITION OF A 200A LOAD CENTERS AND A 13.5 KWH TESLA POWERWALL BATTERY BACK UP TO EXISTING SFD WITH A EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13160	13041-10000-26192	19440 W ROSITA ST	91356	3	168B117   327	2178014013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.15657	-118.55706	"PV1. ""$0 PERMIT FEE DUE TO 2012 SB 1222""  ROOFMOUNTED PHOTOVOLTAIC SYSTEM  INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 13kW SYSTEM.52 TSM 250 MODULES WITH FRONIUS IG INVERTER."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13161	16041-20000-42429	12385 N SAN FERNANDO ROAD #36	91342	7	219B149   648	2611007050	(T)(Q)RAS3-1-CPIO, C2-2D-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.29518	-118.45448	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13162	17041-20000-00021	17150 W VENTURA BLVD	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.16032	-118.50749	new fire alarm system 43 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13163	12041-20000-10754	2555 N CREST VIEW DR	90046	5	153B169    96	5564032043	A1-1XL	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.11863	-118.38952	TI for a bathroom. Plan check for energy. 485 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13164	12041-10000-02938	600 W 9TH ST # 125	90015	14	127-5A207  12	5138001***	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.04534	-118.26103	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR STARBUCK'S COFFEE SHOP #125 TI IN EXISTING HIGH RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13165	16041-30000-23807	1350 S SEPULVEDA BLVD	90025	5	129B149     8	4324017904	OS-1XL	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.05226	-118.44802	Plan check for Title 24 only. Project site is an existing park. Project scope is the replacement of parking lot lighting. Total lighting area = 81,034 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13166	18041-20000-06447	5118 S FIGUEROA ST	90037	9	108B201    15	5001033016	RD2-1	South Los Angeles	Southeast Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	33.99609	-118.28248	PV1.  Install 5.52 kW DC roof mounted grid tied PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13167	12041-20000-04703	315 S DETROIT ST	90036	4	135B181   226	5508002009	[Q]R4-1	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Apartment			03/01/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	08/03/2012 12:00:00 AM	ADDRESS	34.0683	-118.34524	New roof mounted PV system with 6.8KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13168	17041-10001-04627	20101 W RINALDI ST BLDG S2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.27545	-118.57197	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 3. CHANGES INCLUDE ADDING SITE LIGHTING, REPLACING EXTERIOR LIGHTS, REVISING TITLE 24, AND REVISING PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13169	16041-10000-13907	670 S SANTA FE AVE	90021	14	124-5A217 135	5164018003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.03584	-118.23011	T-24, PC FOR ENERGY ONLY. CHANGE OF USE TO A CATERING KITCHEN. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 2055 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13170	12041-20000-10603	1730 N CAMINO PALMERO	90046	4	147B181    26	5550032***	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.10243	-118.34977	T-24 plan check. Garage for condominium. No generator. Emergency lights are existing. Permit is under 11041-20000-24022.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13171	15041-10000-19058	4909 S CRENSHAW BLVD	90043	8	111B185   464	5013017024	[Q]R4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.99795	-118.33124	NEW FIRE ALARM SYSTEM FOR AN (E) BUILDING, CHURCH. 35 FIRE ALARM DEVICES AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13172	18041-10000-08280	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	34.2426	-118.55846	Alterations for at a Chase bank- replacing outdoor and indoor luminaires with LED type using existing branch circuitsTotal area is 14798sqft.PLAN CHECK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13173	16041-10000-26925	1108 S LOS ANGELES ST #200 & 300	90015	14	126A209   262	5145021022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.03808	-118.25716	"T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM WHSE TO OFFICE @ 2ND & 3RD FLOORS & (E)  RETAIL @ 1ST FLR. OF (E)   3-STORY  ""URM"" BLDG.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 14185 SQ. FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13174	14041-10000-06680	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.03396	-118.24117	TI for vacent space, 1 story, one spce, tailored method, 2240 sqrft, retail, exit sign , title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13175	10041-20000-13760	8150 W SUNSET BLVD	90046	5	147B173   327	5554007014	C4-1D	Central	Hollywood			1942.00	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.09781	-118.36653	OUTDOOR LIGHTING. TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13176	15041-20001-39763	5800 W SUNSET BLVD PHASE 1	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM			PC Approved	10/13/2016 12:00:00 AM	ADDRESS	34.09728	-118.31693	Revisions to approved set.  Field revision changes made to feeder and branch circuit ratings.  Approval for changes under delta RFI#120 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13177	17041-10000-42658	14806 W RYAN ST	91342	7	225B149   455	2505004015	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.31017	-118.45483	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.51KWdc / 5.0KWac.(19)MODULES-SOLARWORLD 290(19)OPTIMIZERS-P320 SOLAREDGE(1)INVERTER-SOLAREDGE 5000H	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13178	15041-20002-14089	3760 N GLENRIDGE DR	91423	4	162B157   730	2272027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.13898	-118.43214	Revisions to approved set.  Wiring detail changes.  Delta-1 revisions only.  (((Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Building integrated PV panels are connected to two central inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13179	14041-20000-03116	125 E DON ST	90744	15	039B205   735	7422001027	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Closed	05/14/2015 12:00:00 AM	ADDRESS	33.79849	-118.26287	PV1 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13180	13041-20001-28891	4811 N ADELE CT	91364	3	168B113   219	2175026027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.15768	-118.57172	((Expedite fees ONLY))PV1 TRANSFORMERLESS SYSTEM. USING SOLAR OPTIMIZERS. TOTAL SYSYEM SIZE 5.1 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13181	19041-10000-17373	6534 N PLATT AVE 1	91307	12	180B093   512	2036024053	(Q)C1-1VL, (Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL, C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.18874	-118.64245	FULL PC ENERGY AND PWR FOR NEW FLORAL PRE, CONCIERGE OFFICE. NEW SERVICE LINEUPS AT SERVICE DELI, BAKERY, MEAT AND SEAFOOD DEPTS. RELOCATE AND/OR PROVIDE NEW GONDOLAS AND DISPLAY REFRIGERATED CASES. MODIFY MAIN SALES AREA LIGHTINGAND SERVICE AREA LIGHTING. ACCESSIBLE MODIFICATIONS TO PUBLIC RESTROOMS, PARKING STALLS, SIGNAGE. AREA OF SCOPE IS 47,575-SF. PROJECT INCLUDE 1 NEW PANEL AND NEW CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13182	15041-10001-12047	6250 N TOPANGA CANYON BLVD 1515	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	PC for Power per inspector request.Permit fees paid under 15041-10000-12047This is PC only((Change of use from retail to salon.  Plan check for energy only.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13183	17041-10000-35161	5200 N LANKERSHIM BLVD #420	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC FOR OFFICE TI IN A HIGHRISE BUIILDING (4TH FLOOR). TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA  2254 SQ.FTB3 17016-20000-26998	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13184	12041-10000-06291	1240 S NAOMI AVE	90021	14	121-5A213  54	5130006900	PF-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.02783	-118.24431	Plan check for installion of new 1600A service, switchboard for new photovoltaic system interconnection, and T24 Energy for new carport lighting. Existing building load to remain.  Photovoltaic system plan check  under #12041-10000-06288	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13185	16041-20001-34885	17451 W OSBORNE ST	91325	12	195B129   117	2768020012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.23355	-118.51524	RSES expedited plan check fee per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13186	16041-10000-29852	300 S LA CIENEGA BLVD	90048	5	138B173   769	5511032053	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM			PC Approved	08/23/2016 12:00:00 AM	ADDRESS	34.07301	-118.37628	PC for energy only to exiting coffee bean shop. Interior remodel. Adding new lighting and power. Total sqft = 1313.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13187	18041-10000-17857	14333 S FIGUEROA ST	90248	15	075B201    96	6119008040	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.90077	-118.28314	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13188	18041-10000-30713	729 W MANCHESTER AVE	90044	8	097-5A201 245	6032015901	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Closed	11/06/2020 12:00:00 AM	ADDRESS	33.96022	-118.28643	PLAN CHECK FOR POWER AND ENERGY FOR - (N) 2 STORY NAVIGATION CENTER FOR THE CITY OF LOS ANGELES; INCLUDE BIN STORAGE, RESTROOM FACILITIES, LAUNDRY, TRAINING ROOM AND ADMIN OFFICES FOUNDATION/SITE WORK ONLY - SERVICE SIZE = 600A, APPROX CONNECTED LOAD = 400A, TOTAL AFFECTED AREA 5585 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13189	14041-10000-17313	14931 W CALIFA ST	91411	4	177A149   141	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.17768	-118.4586	Plan check for fire alarm. Total devices = 165Install new fire alarm system. 3 story office building. B occupancy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13190	17041-20000-00686	20014 W HIAWATHA ST	91311	12	207B113   263	2708018005	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.26043	-118.56921	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (58) AC PV modules and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13191	13041-10000-07125	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			03/19/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.04594	-118.25757	7-STORY MIXED USED BUILDING 700 UNIT APARMENT, OVER 2-LEVEL SUBTERRANEAN GARAGE :  upper 6 levels residential and retail/gym on the 1st floor. None highrise.. 5000A SERVICE;__this note : by Nabil, this methane zone.  was indicated the level changed from 5 to 2.  see plan number 12041-10000-29828	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13192	10041-10000-07025	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***		Central	Hollywood	Hollywood Hills West	YES	1882.00, 1897.01	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.1504	-118.32742	Install 500 KW non-required generator and ATS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13193	15041-20000-34961	4849 N VAN NUYS BLVD 1ST & 2ND-FLOORS	91403	4	169-5A151  98	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.15918	-118.44892	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES REPLACING EXISTING FLUORESCENT LIGHTS WITH NEW LED LIGHTS ON THE FIRST AND SECOND FLOOR CORRIDOR. TOTAL AREA IS 3479 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13194	17041-20000-45333	3649 N CROWNRIDGE DR	91403	5	162B141   421	2280009020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.13703	-118.47627	permit fee $0.00 by state senate bill no.1222pv1install rof mounted pv system sized 17.3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13195	17041-20000-07541	20929 W VENTURA BLVD Building A	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 1200-amps.Note: Building application has been generated under 16016-20000-22112	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13196	15041-20000-10695	13074 N GLADSTONE AVE	91342	7	222B157    66	2512010011	A1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	34.30784	-118.42451	Installation of new GROUND MOUNTED PV solar array.  Total system size = 5.5 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13197	18041-20000-15819	20629 W CHESTNUT CIR (#274)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.29331	-118.58338	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13198	17041-20000-45582	16633 W OAK VIEW DR	91436	5	168B137   395	2289020013	R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.15694	-118.49746	Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(36) 300W pv modules. (2) 5kW Tesla Powerwall 2s.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13199	14041-10000-26044	319 E 2ND ST STE # 202	90012	14	129A213    10	5161017034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.04929	-118.24098	Pc for energy only. Total area 3440 sq ft. TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13200	13041-20000-35308	2587 N HUTTON DR	90210	5	153B157    60	4382010005	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.11884	-118.43191	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 9.5KWAC. 44 MODULES AND MICROINVERTERS. ****LOW PERMIT FEES DUE TO 2012 SENATE BILL****	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13201	10041-10000-17363	10250 W SANTA MONICA BLVD #1010	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM			PC Approved	09/01/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13202	18041-20002-32496	4835 S SEPULVEDA BLVD	90230	11	111B165   200	4215031037	C2-1, R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	34.00052	-118.40294	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 7 ONLY NEW LIGHT FOR THE BATHROOM.  <<<FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW MC DONALD - NEW SERVICE AT 1000A WITH TOTAL AFFECTED AREA = 4956 SF == BLDG PERMIT: 18016-10000-27448>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13203	18041-10000-03714	725 S FIGUEROA ST 15TH FL.	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	05/14/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	Energy plan check for (2) restrooms T.I.  Scope includes new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13204	17041-20001-44865	23002 W SYLVAN ST	91367	3	177B097   149	2039010028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2017 12:00:00 AM			PC Approved	12/29/2017 12:00:00 AM	PIN	34.1842535	-118.62796555	Expedited plan review fee.PV1.  Install 24.08 kW roof mounted grid tied PV system.  (72) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13205	14041-10000-13812	11150 W SANTA MONICA BLVD Suite #200	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.04704	-118.44563	Permit to be pulled at EPC counter only. Plan check for energy only. LESS THAN 400. HIGH RISE. #200. Tenent improvement to an existing office space (2976 sf) in Suite #200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13206	14041-10000-21306	3150 W WILSHIRE BLVD # 206	90010	10	132B197    39	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	TI WORK FOR RETAIL STORE  (+/- 2020 SQ FT).  NO CHANGE OF USE. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13207	18041-10000-33636	9361 N WHITE OAK AVE	91325	12	198B129   154	2766002003	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM			Reviewed by Supervisor	09/11/2018 12:00:00 AM	ADDRESS	34.24067	-118.52024	PC FOR ROOF MOUNTED PV FOR SFD WITH ESS. SCOPE INCLUDES 30 MODULES WITH MICROINVERTERS AND  ENPHASE BATTERY. TOTAL PV SYSTEM SIZE 7.2KW AC/  9.2 KW DC4 NEW AC COUPLED ENPHASE BATTERIES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13208	19041-10000-38744	7850 S NORMANDIE AVE BLDG 9	90044	8	099B197   411	6019016005	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Apartment			09/25/2019 12:00:00 AM	05/19/2020 12:00:00 AM		Issued	05/19/2020 12:00:00 AM	ADDRESS	33.96767	-118.30005	Note: $0 final fees per AB1414PV2 commerical rooftop system, System size is 10KWac/11.1KWdc, system includes 30 modules (HYUNDAI HIS-S370RI ) with optimzers (400P SOLAREDGE OPTIMIZERS) and a central inverter (SE10000H-US) with a line side connection. Note the permit for Bld 8 PV2 system, will be under an express permit, 20041-10000-19412	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13209	12041-20000-22558	4228 N LAURELGROVE AVE	91604	2	165B165   840	2367006005	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.14762	-118.4007	Solar panel installation (Micro-inverters) (3.19kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13210	16041-10000-35874	1635 N BLUE JAY WAY	90069	4	147B169    57	5561026013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM			Verifications in Progress	01/30/2017 12:00:00 AM	ADDRESS	34.10272	-118.38708	SFD 1 STORY OVER BASEMENT W/ATTACHED GARAGE. 800 A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13211	17041-20001-45614	16025 W VENTURA BLVD	91436	5	168B141   547	2261022022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	34.15641	-118.48198	3/4/2019changes to an approved set of plans.  changes noted delta 5.  changes to reflect structural changes, no change in load or energy calcs.  this is plan check only.((((Plan check for power and energy. TI/Remodel for (E) assisted living facility. New 300 kW 120/208V 3ph 4w emergency generator.  New loads and distribution feeding off existing service.  Building permit application #17016-20000-37696.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13212	17041-10000-27797	9051 N LEV AVE	91331	6	195B161   223	2628009008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.23394	-118.41651	ROOF MOUNTED SOLAR SYSTEM SIZE 2.6 KW. TOTAL OF 9 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13213	19041-10000-35933	17383 W SUNSET BLVD SUITE 101	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	34.03917	-118.55529	ENERGY PC ONLY FOR INTERIOR REMODEL OF EXISTING OFFICE SUITE ON 1ST FLOOR. AREA OF SCOPE 7,950SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13214	16041-20000-30272	18903 W RINGLING ST	91356	3	171B121   498	2176010009	RA-1	South Valley	Encino - Tarzana	Tarzana		1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	11/26/2016 12:00:00 AM	PIN	34.16229368	-118.54458786	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13215	15041-20001-29147	7047 N SUNNYSLOPE AVE	91405	2	183B157   324	2328033009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM			PC Approved	09/15/2015 12:00:00 AM	ADDRESS	34.19884	-118.42704	Expedite fees.  Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13216	13041-10000-27250	7263 N COLDWATER CANYON AVE	91605	2	186B161   583	2327016008	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.20271	-118.4156	Remove HID light fixtures and install new fluorescent fixtures.  Title 24 ENERGY plan check only. 3782 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13217	16041-10000-14545	2852 S FORRESTER DR	90064	5	126B165   873	4316013003	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.03936	-118.40382	PV1. NEW SOLAR SYSTEM  ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 32KWdc / 25KWac. INTERCONNECTING THROUGH THE LOAD CENTTER AND MAIN SERVICE PANEL.(100)MODULES-LG LG315N1C-G4 BLACK MODULES(100)MICROINVERTERS-ENPHASE M250Note: Permit fee $0 due to senate bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13218	19041-20000-33448	7121 N CANBY AVE	91335	3	183B125   301	2125001010	M1-2	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			Corrections Issued	08/26/2019 12:00:00 AM	ADDRESS	34.19995	-118.53488	Plan check for new 600A Service, all existing load to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13219	14041-10000-10767	10350 W CROCKETT ST	91352	2	192B177   766	2407022001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.22039	-118.35831	Install roof-mounted solar array, interconnect with main panelSystem size = 3 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13220	15041-20000-11892	12457 W OSPREY LANE Unit 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.97937	-118.41024	Plan check for PV1 roof mounted  system 8 modules (SUNPOWER MODULES SPR-230NE-LK-D) and 1 inverter(SB3000TL -US-22)PV clearance shall  be relevent to Unit #1 of address 12457 Osprey Lane	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13221	14041-10000-29078	6901 N TUJUNGA AVE	91605	2	183B173   184	2320002016	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.19626	-118.37921	Installation of fire alarm monitoring system. 170 devices. 1 fire alarm panel. 1 panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13222	17041-10000-24729	16909 W PARTHENIA ST	91343	12	195B133   421	2688041013	CR-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.22864	-118.50078	Plna check for T24 only, remove outdoor HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13223	19041-20000-14163	14150 W VAN NUYS BLVD #105	91331	6	201B153    32	2645021001	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.25162	-118.4416	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SHOPPING MALL. SYSTEM SIZE IS 14.6KW DC/12KW AC. SCOPE OF WORK INCLUDES (40) HANWHA Q-CELL 365W PV MODULES AND A 12KW FRONIUS SYMO INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13224	18041-20001-12992	16929 W DEVONSHIRE ST	91344	12	204B133   147	2684012044	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.25767	-118.50122	04/16/2018 Changes to an approved set of plans. Changes have been made to reflect field conditions. Single-line diagram and load home-runs have been updated. *****Previous Work Description*****PC for T24 only for new lighting for change of use from retail to restuarant. Installing new lights, receptacles and equipment. B#17016-20000-28924.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13225	16041-10000-40264	380 WORLD WAY SPACE T85	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	T-24, PC FOR ENERGY ONLY. EXPANSION OF THE SEVEN ELLEVEN  SPACE. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES FOR A 7 ELEVEN STORE FOR SPACE T85. TOTAL AFFECTED AREA IS 1503 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13226	18041-10000-41613	767 S ALAMEDA ST 260	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	**This is plan check only, permit is obtained under 18041-90000-44864**ENERGY PLAN CHECK FOR AN OFFICE TI SCOPE OF WORK IS INCLUDED TITLE 24 ONLY WITH NEW EQUIPMENT AND LIGHTING WITH 4369 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13227	10041-20000-25892	5601 N DE SOTO AVE 4th floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	05/09/2011 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	T.I. for Kaiser Foundation in Chemotheraphy and Non-Chemo Clean rooms.  Install subpanels, branch circuits, and lighting.  Plan for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13228	14041-20000-20535	10913 N BAIRD AVE	91326	12	210B125   642	2717013002	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.26918	-118.53747	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. DERATING OF MAIN BREAKER. TOTAL 45 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13229	14041-20001-13635	16355 W KINZIE ST	91343	12	201B137   347	2677018016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.24858	-118.48907	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13230	17041-20001-12188	1611 N AVENUE 54	90042	14	156A227    82	5479010015	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.1231	-118.19878	5.23.2017 - Adding (4) EnPhase M250 microinverters and (4) 295W pv modules to pv system installed under master  permit (17041-90000-12188). PV OCPD changed to 20A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13231	13041-20000-19173	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	existing mix use low rise. pc for t24 energy only for common areas. work done in leasing offices. total area 2104 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13232	16041-20000-14512	15451 W SAN FERNANDO MISSION BLVD	91345	7	210B145   127	2664007025	(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.27217	-118.46834	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the 1st, 2nd, and 3rd floor restrooms. Total lighting area = 1,611 sq. ft.Note: Building application has been created under 16016-20000-08776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13233	13041-20000-15232	11232 W ERWIN ST	91606	2	177B173   440	2336031005	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.18294	-118.37594	pv1 single family dwelling. total system size 3.5 kw. using 17 modules and transformerless inverter. nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13234	15041-20001-35909	6749 N FALLBROOK AVE #619	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.1925	-118.62407	02/19/2016 Changes to an approved set of plans. Changes have been made to the lighting fixture types. All changes have been reflected onto the Title 24 Compliance forms and have been clouded and marked as Delta 2.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement (change of use from retail to beauty salon). Total lighting area = 5,989 sq. ft.Note: Building application has filed under 15016-20000-23404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13235	16041-30000-35143	7118 N JORDAN AVE	91303	3	183B105   328	2111025021	[Q]R3-1-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.19971	-118.60272	Installation of fire alarm system in new 2 story 9 unit apartment building.  Total system size = 1 FACP + 57 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13236	18041-10000-22750	123 W ANN ST	90012	1	135A217    35	5409005034	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.06552	-118.23177	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13237	17041-20000-16950	10260 N TUJUNGA CANYON BLVD	91042	7	204B197   973	2565013023	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			05/19/2017 12:00:00 AM			Verifications in Progress	04/05/2018 12:00:00 AM	ADDRESS	34.25387	-118.29087	Plan check for power and energy. Project site is a new 12-unit apartment building. Work includes an 800-amp service and associated distribution equipment. Total lighting area = 9,000 sq. ft.Note: Building application has been generated under 17010-20000-01953	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13238	11041-20000-00556	12366 N MONTERO AVE	91342	7	219B161   271	2525027014	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM			PC Info Complete	01/11/2011 12:00:00 AM	ADDRESS	34.29458	-118.40886	Plan check T24 Energy (general/emergency) lighting on 1st and 2nd floor office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13239	11041-20000-25394	4826 W BONVUE AVE	90027	4	153B197   480	5588017034	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.11302	-118.29614	New 5.7 KW roof mounted PV system for a single family residence.  Applicant is using ENPHASE M215.  A variance has been filed to use the M215.  The permit has been puled for the 26 modules and 26 inverters under 11041-10000-20496Applicant decided not to submitt, therefore the variance has not been paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13240	16041-10001-38464	8407 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Issued	11/23/2016 12:00:00 AM	ADDRESS	34.22266	-118.62737	Plan check for power only new 1,200A  switch gear supply existing ats and new 400 A distribution connecting existing load	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13241	11041-10000-26068	7301 W WORLD WAY WEST 1st Floor	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Ceiling was replaced in existing data center room, located on the 1st floor, Admin West (No room number).  New lighting is being installed.  Entire room is on a standby generator.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13242	15041-10000-04464	6400 N CANOGA AVE Suite 250	91367	3	180B105    61	2149001020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM			Corrections Issued	02/13/2015 12:00:00 AM	ADDRESS	34.18665	-118.5972	Title 24 plan check only.  Total area = 1,558 sq. ft.T.I. to existing (non-highrise) office space including new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13243	13041-10001-26344	23956 W HAMLIN ST	91307	12	180B089   672	2033006021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.1883	-118.64838	][][]EXPEDITED PER APPLICANT REQUEST ][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A  NON STANDARD PLAN , XFORMERLESS SYSTEM; SYSTEM SIZE IS 3.675KW DC WITH (15) MODULES: TRINA #TSM-245PA05.18(1) POWER-ONE #AURORA PVI-3000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13244	13041-10000-33205	740 S OLIVE ST #103	90014	14	127-5A209  18	5144013034	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.04537	-118.25644	CHANGE OF USE FROM RETAIL TO DOMINO'S PIZZA RESTAURANT.  TENANT IMPROVEMENT AREA - 1,805 S.F. hirise. ground floor. emergency lights added	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13245	11041-10000-20080	1611 S BEVERLY GLEN BLVD 1-6	90024	5	132B157   380	4327005023	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			09/29/2011 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.05941	-118.42528	NEW 12-UNIT APARTMENT WITH NEW 800A SERVICE.  4-STORY, WITH UNDERGROUND PARKING.  PLAN CHECK FOR POWER AND ENERGY.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13246	18041-10000-38555	5151 W ROMAINE ST	90029	13	144B193  1410	5537020039	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.08864	-118.30414	PC FOR NEW FA SYSTEM IN A 76 UNIT SENIOR APARTMENT BUILDING 4 STORY WITH BASEMENT. SCOPE INCLUDES 1 PANEL AND 302 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13247	10041-10000-10499	671 S CLARENCE ST	90023	14	124-5A219  67	5171018001	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	09/08/2010 12:00:00 AM	ADDRESS	34.03656	-118.22236	NEW 600A SERVICE FOR AN EMPTY COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13248	19041-20000-29173	12050 W ROSCOE BLVD pv3	91605	6	192B165   504	2310001035	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM			Reviewed by Supervisor	08/22/2019 12:00:00 AM	ADDRESS	34.22143	-118.39587	pv3install roof mounted pv system szied 20KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13249	13041-10000-20540	1421 E 41ST PL	90011	9	114A211    36	5116011020	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.00805	-118.24871	PV1 2.376 KW 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 11) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: yingli {YL245P-29b}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13250	19041-10000-41776	11611 W SAN VICENTE BLVD STE 920	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.0541	-118.46261	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI IN AN EXISTING OFFICE SUITE LOCATED IN AN HIGHRISE. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2299 SQFT. B# 19016-10000-23832	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13251	19041-20000-15356	8219 S HANDLEY AVE pv1	90045	11	099B169  1270	4105027002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	33.9638	-118.38054	pv1install roof mounted pv system sized 7.6KW AC with (1) LG batery 5KW interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13252	14041-10001-24489	621 W 117TH ST	90044	15	084B201   472	6088012016	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	01/16/2015 12:00:00 AM	ADDRESS	33.92747	-118.28568	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): POWER-ONE AURORA PV1-5000-OUTD-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13253	18041-10000-46944	812 N HIGHLAND AVE	90038	4	141B185   212	5524004025	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.08567	-118.33841	PC FOR NEW ENERGY STORAGE SYSTEM CONSIST OF 1 UNITS (14KWH EACH - TESLA POWER WALL).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13254	13041-10000-22921	615 1/2 S 6TH AVE	90291	11	111B145  1320	4240014028	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM			Verifications in Progress	09/20/2013 12:00:00 AM	PIN	33.99710983	-118.47050745	PV1.  INSTALL 8.82 KW DC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13255	14041-20001-15315	20480 W CELTIC ST	91311	12	210B109   100	2707026033	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.27112	-118.57951	Expedited plan check per applicant request.  (((PV1.  Install 8.925 kW roof-mounted, utility-interactive PV system.  (2) transformerless inverters with DC converters.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13256	16041-20002-02117	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	34.0965	-118.30717	[[ 10/19/16 CHANGES TO APPROVED SET. INSTALLATION OF A 600AMP BREAKER AND 2000AMP GFI BREAKER ON MAIN 5000AMP BOARD. CHANGES ARE CLOUDED]]]] TI for an existing building (offices). Plan check for power. Core and shell only.  New service 2,000A. Existing lighting to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13257	18041-10000-28632	8700 N SEPULVEDA BLVD	91343	6	195B145   507	2654012029	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Issued	07/31/2018 12:00:00 AM	ADDRESS	34.22847	-118.46742	PLAN CHECK FOR FOR TITLE 24 FOR REMOVAL OF HID FIXTURE TO NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13258	16041-10000-35261	20255 W GAULT ST	91306	3	183B113   164	2135001028	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.19935	-118.57507	Addition of 17 new solar panels, 17 new microinverters, and 1 new AC load center to existing solar system.  Rooftop solar system on existing single family dwelling.  Total size = 10.92 kW (4.25 kWac new)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13259	14041-10000-14247	4848 E ELDRED ST	90042	1	151-5A223 213	5471019046	RE11-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.10811	-118.20872	Installation of 3KW ROOF-MOUNTED PV SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13260	15041-20000-20597	20968 W VENTURA BLVD	91364	3	171B109    83	2167024023	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.1664	-118.59057	TI to existing commercial building. Change of views from retail to dental clinic. Plan check for power and energy. Adding new lighting including emergency. Total sqft. 3,960.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13261	15041-20000-10048	12460 W OSPREY LANE Unit #2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	Plan check for PV roof mounted system for tri-plex unit #2 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10046	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13262	14041-20000-10216	501 W EL SEGUNDO BLVD	90044	15	081B201   259	6132002020	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	PIN	33.91663801	-118.28317828	New commercial single-story retail building.  4 tenant spaces.  1600 A  208Y/120 3ph-4w service.  Power and energy plan check. {plancheck is for above ground only. no underground feed part of plan review}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13263	16041-10000-06900	4550 N VAN NUYS BLVD	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.15445	-118.4485	FULL PC FOR POWER AND ENERGY. SHELL AND CORE UPGRADES TO RETAIL & RESTAURANT TENANT SPACES.  CHANGE OF USE FROM RETAIL TO RESTAURANT FOR A1/A2.  SCOPE INCLUDES TWO NEW 2000A 208/120V 3 PHASE, 4 WIRE SERVICES 'MSA' AND 'MSB'. TOTAL AFFECTED AREA IS 18,000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13264	12041-20000-14547	1801 S CENTURY PARK WEST	90025	5	132B157   448	4319009050	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	06/22/2012 12:00:00 AM		Permit Expired	07/16/2014 12:00:00 AM	PIN	34.05877581	-118.42130815	T.I. to existing space (Dinning).  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13265	17041-10000-34428	2900 W TEMPLE ST	90026	13	138A203    79	5156016027	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.07395	-118.2787	NOTE FEES ARE $0 DUE TO SENATE BILL 1222.PC FOR PV SYSTEM. TOTAL OF 136 MODULES AND 2 CENTRAL INVERTERS. SYSTEM RATED 40KW AC. SYSTEM USES POWER OPTIMIZERS. NET METER. CONNECTING TO EXISTING SERVICE AHEAD OF MAIN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13266	19041-10000-42395	615 S LA FAYETTE PARK PL	90057	10	135A201   216	5077006900	OS-1XL	Central	Wilshire	MacArthur Park, Rampart Village, Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	03/23/2021 12:00:00 AM	ADDRESS	34.06239	-118.28293	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS ONE NEW FIRE ALARM PANEL, A NEW BATTERY AND 70 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13267	14041-10001-08927	5934 N TROOST AVE	91601	2	177B169   943	2339009055	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	34.17862	-118.38651	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.35 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(19) MODULES: SUNIVA OPT265-60-4-1B0}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13268	19041-10000-34010	1771 W BLAKE AVE BLDG 11	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/30/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	11 OF 11. BLDG 11POWER PLAN CHECK FOR 1000A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDING AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13269	11041-10000-17304	11666 W OLYMPIC BLVD	90064	11	123B149   388	4260013029	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.03435	-118.44732	T.I.  Existing 7-Eleven. replacing the existing light fixtures with LED fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13270	16041-20000-01940	18751 W VENTURA BLVD	91356	3	174B121   510	2160002050	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.17151	-118.54234	TI to existing commercial building. Change of use to 1st floor from office to medical office. Plan check for power and energy. Total sqft. 6,109.Note: Building application has been generated under 15016-20000-24707	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13271	14041-20000-35624	8604 N WHITE OAK AVE	91325	12	195B129   574	2787031026	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2014 12:00:00 AM			PC Approved	12/24/2014 12:00:00 AM	ADDRESS	34.22691	-118.51974	Change from previously approved plans (14041-20000-26374).  Change in the AC disconnect from Non-fuse to 90 A fuse.  Note: Permit is under the previously approved application.*****Previous Description*****PV1 SFD. TOTAL SYSTEM SIZE 12 KW  AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 40 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13272	13041-10000-08402	10768 W BELLAGIO ROAD	90077	5	138B149     6	4362010001	A1-1XL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/19/2013 12:00:00 AM	ADDRESS	34.0802	-118.45043	T24 plan check for a 2000 sq ft retail space in a 2-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13273	19041-10001-34918	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.04797	-118.25815	REVISION TO AN APPROVED SET CHANGE UNDER DELTA 4. CHANGE INCLUDES CHANGING PART OF THE LIGHTING LAYOUT AND UPDATIING T-24 FORMS. PERMIT UNDER ORIGINAL---ORIGINAL SCOPE--- T-24, ENERGY PC ONLY. TENANT IMPROVEMENT OF AN (E) SPACE WITHIN 'MACYS' DEPARTMENT STORE FOR A NEW 'CHOP STOP' FAST FOOD RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1769 SQ. FT.   B#19016-10000-27868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13274	14041-20000-09286	16915 W NAPA ST	91325	12	195B133   507	2689018030	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Apartment			04/08/2014 12:00:00 AM			Reviewed by Supervisor	05/02/2014 12:00:00 AM	PIN	34.22705349	-118.50207694	PV2  COMMERCIAL ROOF TOP. TOTAL SYSTEM SIZE 32.8 KW AC. USING 3 CENTRAL TRANFORMED INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13275	17041-20000-19654	17909 W PALORA ST	91316	5	168B129   137	2182006018	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.15972	-118.52223	Plan check for roof-mounted solar pv system with AC coupled battery backup system.6kW ungrounded system. (23) 325W pv modules. (1) 5kW Tesla Powerwall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13276	12041-10000-00137	4730 S LINCOLN BLVD B	90292	11	105B153   149	4224014018	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	33.97991	-118.438	T.I. to an existing restaurant.  New 100A service, 3Phase, service with 2 subpanels, lighting, and outlets.  PLAN CHECK ONLY for ENERGY, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13277	10041-10000-05566	920 E PACIFIC COAST HWY	90744	15	036B209   665	7425003002	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Issued	08/11/2010 12:00:00 AM	ADDRESS	33.79072	-118.2518	Install sub-panel and Hay press.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13278	17041-10000-30898	13576 W DESMOND ST	91331	7	210B157   125	2523005023	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.27454	-118.42833	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURE T-24.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13279	13041-10000-01628	20750 W VENTURA BLVD	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	02/01/2013 12:00:00 AM	ADDRESS	34.16638	-118.58506	T24 for 1st and 2nd floor. 5216 Sqrfeet. Low rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13280	16041-10000-27381	1809 S WESTMORELAND BLVD	90006	10	126B193   735	5074016020	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.04097	-118.3068	PC for PV1. Scope includes 32 modules and 32 microinverters installed in roof. Total solar system size is 7.68 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13281	11041-10000-04132	1480 W FRANCISCO ST	90501	15	057B193   130	7351037020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	33.85006	-118.30199	TENANT IMPROVEMENT BUILD OUT OF EXISTING SHELL MEZZANINE. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13282	14041-10001-07859	1563 W 218TH ST	90501	15	048B193    57	7346002038	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	33.83038	-118.30596	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13283	19041-10000-43549	21536 W DEVONSHIRE ST	91311	12	204B105   833	2747025038	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	34.25698	-118.60044	0$ final fees per AB1414ROOF TOP SOLAR PLAN CHECK FOR 30KWac (34.127 KW CEC AC) (38.28 KWdc) USING 116 AXITEC-AC-330P/156-72S MODULES, 116 SOLAREDGE P400 OPTIMIZERS, AND 3 SOLAREDGE SE10000H-US INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13284	16041-20001-38382	9301 N TAMPA AVE #182	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	6.5.2017 - Plan check for modifications to approved set. Update lighting plan. New fixture A replacing fixture R2. Update T24 documents to reflect changes. Changes clouded and delta'd 1, 2, and 3.======Plan check for Energy only, T.I. of kids footlocker. Reusing existing panel and circuits for lighting and receptacles. Total effected area: 2,605 sq.ft(Ref: B16WL05385)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13285	16041-10000-41460	5420 N SAN FERNANDO ROAD WEST	90039	13	165B201   257	5593005050	M2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00, 3017.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	34.15089	-118.27467	BUILD OUT OF COLD ROOM INSIDE EXISTING WAREHOUSE. ADDITIONAL LOAD LESS THAN 400A. PC FOR NEW LIGHTING. T24 ENERGY ONLY.Note: Permit was Issued under: 17041-90000-04392	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13286	10041-10000-13801	3939 S CRENSHAW BLVD #E	90008	8	117B185  1015	5032002058	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.01358	-118.33646	Change of use from Hollywood Video to a new restuarant (Buffalo Wild Wing Grill & Bar) in existing building.   Install new panels and branch circuits.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13287	13041-10000-19435	1975 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.06159	-118.20463	Lighting improvements in USC Keith administrative building lobbies.  Removal of existing fixtures and installation of new fixtures.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13288	16041-10008-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	Change to an approved set by adding new load to EV panels. all load will reflect to the service load calculation.All changes clouded under delta-16 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13289	18041-20001-05397	22500 W FRIAR ST	91367	3	177B101    10	2039025004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.1854	-118.61709	[[7/27/18 CHANGES TO APPROVED PLANS. REVISING THE SYSTEM SIZE TO 19.146 CECAC, REMOVING 4 MODULES, 0$ PERMIT FEES DUE TO SENATE BILL 1222,  AB1414]]]Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (2) inverters, (79) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13290	16041-10000-31919	4410 W AVENUE 42	90065	14	159A217   146	5684006006	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Issued	09/20/2016 12:00:00 AM	ADDRESS	34.13071	-118.23009	PC FOR SOLAR WITH MICROINVERTES. SYSTEM SIZE IS 2.75KW.INCLUDES:10 MODULES HANWHA Q PLUS -G3 27510 MICROINVERTERS ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13291	19041-20001-12853	5156 N WINDERMERE AVE	90041	14	163-5A221 246	5671017002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM			PC Approved	05/08/2019 12:00:00 AM	ADDRESS	34.14137	-118.21699	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR MINOR RELOCATION OF SERVICE EQUIPMENT.CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13292	13041-10000-14752	9102 N SEPULVEDA BLVD	91343	7	198B145   383	2656023027	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.23593	-118.46733	Catering restaurant TI.  Newly connected load < 400A.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13293	16041-20001-02114	5725 S ST ANDREWS PL	90062	8	108B193  1136	5005023020	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	33.99021	-118.31148	Expedite per applicant request. {{{{{{Plan check for PV roof monted system. System size: 3.8kW with 9 modules and 1 inverter(3.8kW)}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13294	15041-20000-06551	8122 N LESNER AVE	91406	6	189B133    87	2204029002	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.21802	-118.50331	PV1 SFD TOTAL SYSTEM SIZE 3.8 KW AC USING CENTRAL TRANSFORMER SYSTEM WITH 12 MODULES. UNGROUNDED INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13295	13041-10000-28802	10759 W PICO BLVD	90064	5	126B157   785	4320004091	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.04124	-118.42652	"TITLE 24 ENERGY PLAN CHECK ONLY FOR SIGN (6) TOTAL. EINSTEIN BROS BAGEL. DESCRIPTION FROM BUILDING PERMIT : (2) SETS CHANNEL LETTERS FACELIT WALL SIGN 35""x 21'-0"" SING READS, ""EINSTEIN BROS BAGELS"", (1) 48"" DIA CHANNEL LETTER ""EINSTEIN BROS BAGELS"" W/ LOGO,  (1) 30"" DIA WINDOW SIGN, ""NOW BAKING BAGELS"", (1) 30"" DIA WINDOW SIGN ""EINSTEIN BROS BAGELS W/ LOGO."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13296	17041-10000-02808	8044 W 3RD ST	90048	5	138B177   755	5511028013	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.07191	-118.36531	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO SMALL CAFE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 602 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13297	17041-20000-40046	7941 N RANCHITO AVE	91402	6	189B153   540	2214009011	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.21518	-118.43474	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard lan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13298	19041-10000-20248	15353 W WEDDINGTON ST	91411	4	172-5A145  36	2250001045	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			05/29/2019 12:00:00 AM			PC Approved	05/29/2019 12:00:00 AM	ADDRESS	34.16681	-118.46771	PLAN CHECK FOR TITLE 24 ONLY FOR OUTDOOR LIGHTING. PERMIT WAS PULLED UNDER EXPRESS 19041-20000-14942	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13299	14041-10000-28740	3612 E LAVELL DR	90065	1	151-5A217  41	5460012026	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.11114	-118.22846	PV1, 5kw roof-mounted system including (1) inverters, (21) modules and power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13300	16041-10000-44069	10250 W SANTA MONICA BLVD # 2540	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""GAP"" Ste. 2540.  Install new Xfmr, and  panels, total area 9,896 sq.ft*New load 134A to MS-ELA42"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13301	15041-10000-28065	301 W WORLD WAY	90045	11	090B161    33	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Closed	02/06/2019 12:00:00 AM	PIN	33.94419006	-118.40690837	Added exterior bench LED lighting to refurbished central terminal area for parking structure 3.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13302	19041-20000-51804	9300 W HAZEN DR	90210	4	153B165   287	4388019024	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.11479	-118.39662	Plan check for PV roof mounted system and Energy Storage System, PV system size: 9.38KW DC with 28 PV Modules and 14 microinverters. Energy Storage System size: 27KWh, 2 Energy Storage Device Tesla Power Wall, 2 new sub-panels	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13303	13041-10002-27007	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.0484	-118.26248	((((6/3/2014: ADDING FIRE PUMP AND OTHER NEW LOADS. CHANGES MADE TO ENERGY CALCS AS WELL.))))(((4/25/2014: RELOCATING BIKE RAKE ENCLOSURE. ENERGY CALCULATIONS TO BE VERIFIED. THIS IS A PLAN CHECK ONLY APPLICATION)))pc for power and energy. 1200A SERVICE. New 6-tier parking structure with offices on the 6th floor.  NOT methane. fire sprinkler throughout? B occupancy as seen on 13010-10000-02439	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13304	17041-10000-35973	510 S BROADWAY	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.04767	-118.25088	FULL PLAN CHECK FOR POWER AND ENERGY - (TI for the 3rd Floor, AND INSTALLATION OF NEW EQUIPMENT ON FLOORS 2,4, & 5). INSTALLATION INCLUDES INSTALLATION OF NEW WATER SOURCE HEAT PUMPS CONNECTED LOAD >400A . TOTAL AFFECTED ENERGY AREA = 5715 SQ. FTVARIANCE FORM WAS SUBMITTED FOR THE FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13305	15041-10001-01358	200 WORLD WAY TERM 2-DEPT LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Info Complete	03/23/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	changes to approved set by ADDITION OF 125w INVERTER for emergency lights AND METERING. changes under delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13306	18041-20000-29444	8631 W 3RD ST Ste 615E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check for power and energy. Project site is a tenant suite in an existing commercial building. Project scope is a tenant improvement to office space. No patient care areas in this scope of work. Total lighting area = 1,740 sq. ft.Note: Building permit has been issued under 18016-20000-11070	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13307	15041-20000-19466	15018 W MARSON ST	91402	6	189B145   445	2209016008	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.21474	-118.46028	Installation of new roof mounted solar PV array.  Total system size = 4.65 kWac.  Microinverter system with 8 Aurora 0.30 and 9 Aurora 0.25	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13308	11041-20000-19549	10960 W WILSHIRE BLVD	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM			PC Approved	09/14/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	T.I.  Remoel of an existing office space.  Plan check is or energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13309	18041-20000-35366	5670 W WILSHIRE BLVD 14th Floor	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for Title 24 only in existing space 14th Floor restrooms and elevator lobby. Total area: 623 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13310	11041-10001-08613	1700 N VERMONT AVE	90027	4	147B197   232	5590026004	C4-1D	Central	Hollywood	Greater Griffith Park		1891.01	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.10191	-118.29159	STARBUCKS TENANT IMPROVEMENT, CHANGE TO PREVIOUSLY APPROVED TITLE 24.  EMERGENCY LIGHTING IS ON PREVIOUS APPLICATION.  PLAN CHECK IS FOR ENERGY.  PERMIT FEE IS ON PREVIOUS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13311	15041-10000-18814	13610 W STRATHERN ST	91402	6	189B157   435	2214026021	(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.21519	-118.42917	NEW FA SYSTEM, 130 FA DEVICES FOR NEW APT. BLD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13312	18041-10000-13947	7365 N LENNOX AVE	91405	2	186B149   588	2217002042	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.20421	-118.44576	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13313	10041-20000-07771	5601 N DE SOTO AVE MOB II-FL 1-5	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			PC Info Complete	08/06/2010 12:00:00 AM	ADDRESS	34.17126	-118.58861	Installing7 circuit in medical office in NORTHSIDE MOB II of the building on 1st, 2nd and 3rd floor.  plan check is for the three circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13314	18041-10000-09204	6600 N TOPANGA CANYON BLVD #FC2	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR TITLE 24 ENERGY ONLY TENANT IMPROVEMENTS TO EXISTING RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 739 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13315	19041-10000-32074	2807 W SUNSET BLVD	90026	13	141A205    69	5402001041	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.08197	-118.27165	[EPLAN] FUL PLAN CHECK FOR POWER AND ENERGY (FIRST TIME TENANT) FOR ELECTRICAL WORK ASSOCIATED TO THE TENANT IMPROVEMENTS FOR A 2,664 SF. SCOPE OF WORK INCLUDES A NEW 225A PANEL, RECEPTACLES, LIGHTING AND CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13316	19041-10000-34248	750 S LAMAR ST	90031	14	133-5A219   5	5410002818	[Q]M3-1-RIO	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.06186	-118.22511	PLAN CHECK FOR METHANE DETECTION SYSTEM CONSISTING OF 1 CONTROL PANEL, COMUNICATOR, MONITORING PANEL AND AUTODAILER PANEL WITH  63 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13317	12041-10000-06299	1514 W PALOS VERDES DR NORTH BLDG F	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77937	-118.30407	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building F. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13318	12041-10000-27986	1600 N WILCOX AVE	90028	13	148-5A187 308	5546007018	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.09989	-118.33086	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN A RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13319	13041-20000-26999	4219 N SHADYGLADE AVE	91604	2	165B165   887	2367007016	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.14734	-118.40202	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 8.4KWAC. 28 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13320	18041-10000-19007	15700 W SHERMAN WAY	91406	6	183B141   157	2224003070	R1-1, R3-1, [Q]CR-1VL, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.20096	-118.47555	T-24, PC FOR ENERYG ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 7000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13321	14041-10000-23030	609 S LINCOLN BLVD	90291	11	111B145   817	4240016053	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM			PC Approved	08/22/2014 12:00:00 AM	ADDRESS	33.99989	-118.46525	t24 only.  commercial building. total area 1255 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13322	12041-10000-27383	333 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   594	2424044021	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Expired	12/09/2014 12:00:00 AM	ADDRESS	34.13838	-118.35964	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS 4982 SQ FT HIGH RISE. EXISTING TIME CLOCK LESS THAN 50% OF LIGHTING FIXUTRES ARE TO BE REMOVED THUS CALCS ARE NOT REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13323	15041-20001-40197	6316 N TOPANGA CANYON BLVD Building C	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.18578	-118.60514	*****VOID*****Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size 84 kWac and consists of (3) inverters, (1) load center, and (285) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13324	15041-20000-04104	1761 S NEW ENGLAND ST	90006	1	126B197   527	5056016020	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2015 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.04137	-118.28786	Changes to an approved set of plans.  relocation of the inverter, meter and ac disconnect.refer to master plan 14041 20000 32871.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13325	17041-20000-46287	8311 N STEPHEN LANE	91304	12	192B093   423	2005017023	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.21966	-118.63878	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. (E) solar system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13326	17041-10000-34446	11939 W SHERMAN WAY	91605	2	183B165    27	2317016011	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.20129	-118.39339	REMOVE METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13327	13041-20000-23339	8111 N VENTURA CANYON AVE	91402	6	189B157    56	2213020024	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			Reviewed by Supervisor	09/05/2013 12:00:00 AM	ADDRESS	34.21843	-118.42895	FULL PLAN CHECK FOR POWER AND NEW FIRE ALARM SYSTEM. ADDING 2 NEW PANELS AND ALTERING SOME LOADS ON OTHER PANELS. 128 DEVICES AND 3 ANNUNCIATORS AND 1 MAIN PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13328	09041-10003-19903	1620-1630 W WASHINGTON BLVD	90007	1	126B197   704	5075036033	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM			PC Approved	06/03/2010 12:00:00 AM	ADDRESS	34.0398	-118.29233	RENOVATING  7 EA TENANT SPACES IN A COMMERCIAL BUILDING ; ELECTRICAL PERMITS WERE OBTAINED ; PLAN CHK IS FOR TITLE 24  FOR THE TENANT SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13329	19041-20001-22473	8362 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM				SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY. CHANGES INCLUDE RELOCATION OF AC DISCONNECT AND AND J-BOX. <<<PV1.  Install 2.8 kW roof mounted grid tied PV system for new home construction.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13330	19041-20000-33158	13051 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.18913	-118.41689	TENANT IMPROVEMENT TO (E) GROCERY STORE PLAN CHECK FOR TITLE 24. TOTAL AFFECTED AREA 18,767 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13331	15041-10001-18837	437 S BROADWAY	90013	14	129A211    47	5149026008	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Closed	11/16/2016 12:00:00 AM	ADDRESS	34.04875	-118.25034	Revision to approved set under 15041-10000-18837. Changes on T-24 and Electrical System (Single line diagram). All changes noted as Delta-3.**TI TO AN EXISTING COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD >400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13332	14041-20001-01953	20847 W KINGSBURY ST	91311	12	207B109   404	2706011049	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.26372	-118.58817	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13333	15041-10000-32983	1132 S ABBOT KINNEY BLVD	90291	11	108B145  1168	4238003024	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	33.99142	-118.46956	Energy plan check for a commercial retail T.I. Scope includes new lighting only. Total area is 1450-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13334	19041-10000-33643	10768 W BELLAGIO ROAD	90077	5	138B149     6	4362010023	A1-1XL-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	05/11/2021 12:00:00 AM		Issued	05/11/2021 12:00:00 AM	ADDRESS	34.0802	-118.45043	Full plan for power and energy. Scope includes one new 4160V 3 PHASE 3 WIRE 600A SERVICE, (700) ckts, (1) back up generator and other associated equipment. Total lighting area cover 158,591-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13335	18041-10000-16840	7640 N GLORIA AVE Ste A	91406	6	186B141    28	2206010020	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Issued	05/08/2018 12:00:00 AM	ADDRESS	34.20953	-118.47917	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13336	15041-10000-22417	11755 W WILSHIRE BLVD 21TH FL-#2150	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	PIN	34.04869377	-118.46238681	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13337	11041-10000-02756	12660 W RIVERSIDE DR # 201	91604	4	168B161   467	2357033017	(Q)C1-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Approved	02/11/2011 12:00:00 AM	PIN	34.15724389	-118.40930375	REMODEL EXISTING MEDICAL OFFICE SUITE- REMOVE  A WALL TO INCREASE A THERAPY AREA;ADDED NEW LUMINAIRES AND SWITCHES AND VACANCY SENSORSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13338	14041-20001-30870	717 S MORENO AVE	90049	11	126B141   235	4264007051	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM			Corrections Issued	01/16/2015 12:00:00 AM	ADDRESS	34.04281	-118.48391	expedite feesPV1 SFD. TOTAL SYSTEM SIZE 20KW AC USING 80 MODULES. USING MICROINVERTER ENPHASE M250. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13339	12041-10000-04552	5800 W FOREST LAWN DR	90068	4	165B189    16	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	1882.00, 1897.01	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.14432	-118.31518	Plan check for new 135KW ground mounted photovoltaic system (parking canopy) at Forest Lawn Hollywood Hills. Upgrade to 600A panel on 400A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13340	19041-20000-09003	12121 W WILSHIRE BLVD 810	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.04386	-118.46816	Plan check only. T24 for installation of receptacles, lighting and controls in existing high rise commercial building, total square footage = 7248 sf.inspection fee paid under online express permit #19041-90000-08393	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13341	17041-10000-30687	1139 W 80TH ST	90044	8	099B197   658	6033020023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	33.96658	-118.29544	New PV1 rooftop solar system with (2) AC Powerwall. (10) modules (1) 3kW AC inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13342	15041-20000-11096	6256 N TOPANGA CANYON BLVD Space 1230-C	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	Plan check for power and Title-24 (energy).  Total area = 3,900 sq. ft.T.I. to retail space at Westfield Topanga.  First time tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13343	16041-10000-15654	121 N GAFFEY ST	90731	15	018B197   925	7451005031	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Apartment			05/04/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	33.74373	-118.29256	PC for energy only to a Hawaiian restaurant. Adding new power, indoor, and outdoor lighting. Total sqft = 1432	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13344	11041-20000-00724	20060 W VENTURA BLVD	91364	3	174B113   486	2166043009	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	06/07/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.17081	-118.57068	"Plan check power and energy for Ralph market interior remodel.  Plan check for power and energy.""COMPLY WITH DEPARTMENT ORDER effective date04/11/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13345	15041-10000-15518	6061 N LANKERSHIM BLVD	91606	2	177B169   633	2338007065	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Expired	06/20/2017 12:00:00 AM	ADDRESS	34.18108	-118.38464	TEMP POWER AT 2000AMP  FOR CONSTRUCTION SITE TO POWER THE DISTRIBUTION BOARD ONLY.  NO LOADS, ALL LOADS TO BE FUTURE. PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13346	12041-20000-16473	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.10686	-118.33085	T.I. to existing building on first floor, suites 107, 109, 111.  Install general/emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13347	16041-10000-42693	19305 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.18681	-118.55422	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total sqft = 27950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13348	17041-10000-08382	2049 S CENTURY PARK EAST S810	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing high rise T.I. Total area: 5580 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13349	14041-20001-05897	4573 N WILLIS AVE	91403	4	168A149   155	2264017037	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Apartment			03/04/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.15404	-118.45544	Fee for expedite only.*****Roof mounted PV system with 18.9KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13350	12041-10000-25426	4433 S ALAMEDA ST D13-D14	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.00295	-118.23924	T24 FOR COMMERCIAL. 350 SQ FT CONDITIONED, 147 SQ FT CONDITIONED. EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13351	16041-10001-30223	14006 W RIVERSIDE DR FC-03	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM			PC Approved	09/26/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	09/26/16Changes to an approved set of plans. Changes include replacing/removing lighting fixtures. Note: Original application is under PCIS#16041-10000-30223(((((TI TO (E) RESTAURANT CONSTUCT NONBEARING WALLS AND INSTALL NEW SERVICE COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13352	15041-10001-17791	101 S JAPANESE VILLAGE PLAZA MALL	90012	14	129A215   347	5161017022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Closed	02/28/2017 12:00:00 AM	ADDRESS	34.04935	-118.23977	PC FOR POWER AND ENERGY. TI FOR OFFICE. FIRST TIME TENANT. TOTAL AREA 4608 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13353	14041-10000-08373	6380 W WILSHIRE BLVD SUITE 800	90048	5	135B173   874	5088014021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.06348	-118.36826	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK IS IN SUITE 800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13354	15041-10001-07105	436 N LA CIENEGA BLVD	90048	5	141B173  1304	5514001005	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	34.07915	-118.37637	Minor revisions to lighting plan.  Plan check for energy.  (((PC FOR T24 ENERGY ONLY. NEW/ MODIFIED LIGHTING DESIGN.permit already issused under 15041-10000-04642)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13355	14041-20003-21443	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			12/21/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Closed	04/05/2016 12:00:00 AM	ADDRESS	34.19603	-118.45077	12/21/15 Changes to an approved set of plans. All changes have been clouded and marked under Delta F. Changes include converting an exercise area into a recreational area on the 2nd floor. Scope includes new 150A  'HPA' panel with new circuits.(((((12/16/2015 Changes to an approved set of plans. All changes have been clouded and marked as Delta E. Changes include the change of use of (1) of the aparment units to an office. Title 24 for the new office have been included.)))*****Previous Work Description*****12/03/15Changes to an approved set. All changes made under delta D. Scope includes adding a new panel/feeder to the main distribution panel. Going from a 49 unit apartment building to 50 unit apartment building. (((Plan check for power and energy (2008 Energy Code). New 49-unit apartment building, 3-stories. Fee calcs provided by applicant - verify. Fire alarm variance filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13356	16041-10001-13424	2720 N GRIFFITH PARK BLVD	90027	4	150A205    12	5433026037	P-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.10737	-118.27281	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. REVISED LIGHITNG FIXTURE SCHEDULE, ADDITION OF TRACK AND UPDATED T24 FORMS. SOME POWER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13357	12041-10000-08629	5555 W MELROSE AVE Bluhdorn-Bldg	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	PLAN CHECK POWER AND ENERGY FOR  TENANT IMPROVEMENT ON 2ND AND 3RD FLOOR OF THE BLUDORN BUILDING. MORE THAN 400A CONNECTED LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13358	18041-20001-19179	4423 N SHERMAN OAKS CIR	91403	5	166-5A145  88	2283019003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	05/29/2018 12:00:00 AM	ADDRESS	34.15116	-118.47048	Expedited plan check fee.PV1.  Install 15.75 kW roof mounted grid tied PV system.  (50) modules with 11.4 and 3 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13359	16041-20000-15911	700 S FLOWER ST Ste 760	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to (E) commercial office space in commercial highrise building.  Plan check for energy.   4180 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13360	15041-20000-02578	11216 N CANBY AVE	91326	12	210B125   950	2715026044	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.27414	-118.5348	PV1Install a roof-mounted solar system on a SFD. Interconnect with a 200A MSP.System size: 3.6kW. Ungrounded system. (12) 255W pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13361	15041-20000-17156	6200 W WILSHIRE BLVD 1st Floor	90048	5	135B177   512	5088015021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Closed	01/08/2020 12:00:00 AM	ADDRESS	34.06295	-118.36347	Plan check for Title 24 only. Project site is the first floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,540 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13362	10041-10000-06176	5333 W ZOO DR UAKARI-HOWLER	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	9800.09	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.14867	-118.28623	PLAN CHECK POWER AND ENERGY FOR UAKARI HOLDING AND EXHIBIT BUILDING #0810-10000-02150. ALSO INCLUDES OROPENDOLA/HOWLER  #0810-10000-02151.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13363	19041-20000-07782	22920 W MARIANO ST	91367	3	171B097   145	2042009015	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.16812	-118.62609	PLAN CHECK FOR NEW 5KW(TESLA POWERWALL) ENERGY STORAGE SYSTEM AND A NEW 200A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13364	17041-10000-46335	3410 W 3RD ST	90020	13	135B197   183	5501024028	(Q)P-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.06884	-118.29027	PC FOR INTERIOR REMODEL. OF ( E ) GROCERY STORE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHT AND RECEPTACLES. NEW LIGHTS ARE INSTALLED IN THE DELI, MEAT AND ENTRANCE SECTION. TOTAL SQ.FT.  39373THIS IS PLAN CHECK ONLY PERMIT PULLED UNDER  17041-10000-32563B# 16016-10000-25936	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13365	12041-10000-01572	5633 N VANTAGE AVE	91607	2	174B165   630	2340025015	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2012 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.17314	-118.39773	New 8.64kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13366	18041-20000-15682	6050 W CADILLAC AVE	90034	10	126B173  1006	5066001048	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Apartment			04/27/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.03776	-118.37635	Plan check for PV roof mounted system. System size: 8.9kWac with 27 modules and 27 microinverters install on appartment building. PV system is connected to service supply side.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13367	13041-20000-11787	9494 W REMBERT LANE	90210	5	153B165   535	4388009018	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.11189	-118.40238	[[PLAN CHECK ONLY. PERMIT ALREADY PULLED ON APPLICATION#: 10241-20000-27451]]New 10kw rooftop mounted photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13368	17041-20000-02201	12527 N SAN FERNANDO ROAD	91342	7	219B149   403	2604033002	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.29765	-118.45762	Plan check for power and energy. Project site is an exising commercial building. Project scope is a tenant improvement/change of use from garage to storage. Total lighting area = 398 sq. ft.Note: Building application has been generated under 16016-20000-25271/16026-20000-00462	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13369	13041-10000-17734	4180 N VERDUGO VIEW DR	90065	1	154-5A219 213	5472010028	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.11787	-118.22289	PV1 2.59KW MICROINV 2STORY. STD. ROOFMOUNT.[ 12MICRO INVERTER: : ENPHASE ENERGY M215-60-2LL-S22] [MODULE:  {REC 250 PE}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13370	14041-10000-12201	7013 W HOLLYWOOD BLVD	90028	13	147B181   114	5548003001	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.1017	-118.34227	BUILD OUT FOR MARSHALLS TI. PLAN CHECK IS FOR POWER AND ENERGY. AREA TOTAL (32,776S.F.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13371	15041-10000-21764	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	T1 SOUTHWEST MODERNIZATION PROGRAM - LANDSIDE TERMINAL 1 LEVELS 1-ROOF.  INSTALL NEW FIRE ALARM SYSTEM. 2 FIRE ALARM CONTROL PANELS AND 851 FIRE ALARM DEVICES. PER APPLICANT FEE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13372	10041-10001-22680	17732 W MELVIN LANE	91325	12	195B129   337	2768012038	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2012 12:00:00 AM			Reviewed by Supervisor	11/13/2012 12:00:00 AM	ADDRESS	34.23045	-118.52155	REVISION TO APPROVED PLANS. PLAN CHECK FOR ADDITIONAL 12.88 KW. NEW TRANSFORMERLESS INVERTER AND MODULES INSTALLED.  TOTAL SYSTEM 32.2KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13373	13041-20000-16108	5841 N MCDONIE AVE	91367	3	174B113    15	2151005027	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.177	-118.57333	PV1 ENPHASE MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 4.97 KW. 23 MODULES AND 1 LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13374	14041-20002-05477	7076 W MAYDOCK PL	91042	7	204B201   440	2565007074	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.25645	-118.28564	Revisions to approved set.  Changes to roof layout and correspondingly updated signage.  $0 submittal fee is due to State Senate Bill SB-1222.  (((Roof mounted PV with optimizers, system size 5KWdc)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13375	11041-10000-23006	1925 S CENTURY PARK EAST suite 2100	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM			PC Approved	10/27/2011 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24 lighting plan check for suite 2100, a portion of the 21st floor.  This is an alteration to the existing lighting system involving reorientaion of luminaires, but no lighting is added, and no lighting removed.  Some walls have been repositioned. All switching, and occupant sensors devices are exiting to remain.  This is an alteration in accordance with section 149(b)(2)(I).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13376	16041-20000-44988	1985 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Approved	12/22/2016 12:00:00 AM	ADDRESS	34.06159	-118.20463	TI to (E) lab and office space in USC building.  Restroom TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13377	10041-20000-23612	3700 N COLDWATER CANYON AVE	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.13809	-118.41286	New fire alarm for Seaver Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13378	19041-20000-13552	5615 W SUNSET BLVD	90028	13	147A193    75	5544028031	C2-1	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Issued	05/08/2019 12:00:00 AM	ADDRESS	34.09825	-118.31196	TI FOR EXISTING COMMERCIAL SELF SERVICE LAUNDRY, REWIRING OF EXISTING BRANCH CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13379	14041-20000-26374	8604 N WHITE OAK AVE	91325	12	195B129   574	2787031026	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.22691	-118.51974	PV1 SFD. TOTAL SYSTEM SIZE 12 KW  AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 40 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13380	16041-10000-39909	223 E CENTURY BLVD	90003	8	091-5A205  86	6052016029	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	33.94575	-118.27084	PV1 roof mounted solar system installation to a single family home. Installing a central inverter rated at 5.0 kw being fed by 20 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13381	18041-10003-34912	4470 N WINNETKA AVE	91364	3	165B113    20	2174026008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.15251	-118.57107	Chnages to approved set, reducing the number of modules installed. Original scope((PLAN CHECK FOR ROOF MOUNTED 11.4KVA/13.75WDC PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE 11400A-US) WITH 50 MODULES USING P320 OPTIMIZERS.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13382	16041-10000-19519	777 W 138TH ST	90247	15	078B197   406	6119003020	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Expired	07/09/2018 12:00:00 AM	ADDRESS	33.90595	-118.28974	PV1. NEW SOLAR SYSTEM ON EXISTING RESEDINTIAL ROOFTOP. TOTAL SYSTEM SIZE 6.36KW DC/ 5.0KW AC. STANDARD PLAN IS BEING USED. (24 )MODULES ( KYOCERA  KU- 265-6ZPA(1)  INVERTER   (PVI-5000OUTD-US )	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13383	15041-10000-40136	1925 S CENTURY PARK EAST 16th-Floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI TO 16TH FLOOR. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13384	15041-20000-10807	18209 W PARTHENIA ST	91325	12	195B125   794	2769019041	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.2289	-118.52978	Plan check for power and Title-24 (energy).  Total area = 1,170 sq. ft. (unconditioned) + 5,630 sq. ft. (conditioned) + 1,000 sq. ft. (outdoor)Project is a new two story office building connected to new warehouse with common roof above a carport.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13385	13041-10000-08072	817 E 59TH ST	90001	9	105B209    14	6007003018	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.98731	-118.26067	convert industrial single story building to kitchen facility for catering establishment; building is subdivided into 8 tenant spaces,approx. simiarly designed;customer requests full plan chk; 400A service is existing; new load is less than 200A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13386	18041-10000-07482	10250 W SANTA MONICA BLVD S1880	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Issued	03/06/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	New revision to approved landlord's plan, noted as Delta-37. Add (1) 60A panel for future Storage Space #S1880. The loads on this panel are for receptacle and lighting only. Total area: 190 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13387	14041-10000-13367	1677 S ROOSEVELT AVE	90006	10	126B193   401	5074025009	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.04286	-118.30196	PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13388	19041-20000-08324	333 S HOPE ST Ste 1125	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Issued	04/12/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	T24 PLAN CHECK FOR TI OF EXISTING HIGH RISE COMMERCIAL BUILDING, INSTALLING NEW LIGHTS AND RECEPTACLES, TOTAL SQUARE FOOTAGE = 3892 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13389	18041-10000-32782	5824 N VAN NUYS BLVD	91401	4	174B149   177	2245005001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.1765	-118.44836	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13390	18041-20000-06685	14145 W CALVERT ST	91401	6	177B153   569	2240022900	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.18179	-118.44146	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13391	16041-20000-00515	17532 W SUPERIOR ST	91325	12	201B129   281	2755009020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Info Complete	01/21/2016 12:00:00 AM	ADDRESS	34.2466	-118.51692	PV1.  Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 10.2kW (4.2+6). Ungrounded system. (46) 265W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13392	16041-10000-16019	1036 N FRIES AVE	90744	15	033B205   982	7420023004	[Q]RD2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	33.78386	-118.26503	PV1 3.2KW SYSTEM. 12 MODULES (SW 260 MONO) AND INVERTER (SMA SB-300TL-US-22) WITH SOLAR METER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13393	13041-20000-28060	1300 N SEPULVEDA BLVD	90049	5	144B141    26	4368001015	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	10/24/2013 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.08696	-118.47442	NEW 1600A SERVICE UPGRADE PLUS DISTRIBUTION BOARDS FOR RELIGIOUS FACILITY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13394	13041-10000-31378	1700 S WESTHOLME AVE 1-10	90024	5	132B157  1050	4326033006	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Issued	11/08/2013 12:00:00 AM	ADDRESS	34.05441	-118.42976	nEW FIRE ALARM FOR 2 STORY OFFICE BLDING. 23 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13395	12041-10000-02029	900 S BROADWAY	90015	14	127-5A209 247	5139002018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.04213	-118.25602	TI IN AN EXISTING 3 STORY COMMERCIAL BUILDING. EXISTING SERVICE, NEW PANELS & CIRCUITS. PLAN CHECK FOR POWER & ENERGY.   <CRA CLEARANCE IS REQUIRED PRIOR TO ISSUING THE PERMIT>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13396	18041-10000-13941	16700 W ROSCOE BLVD	91406	6	189B137     3	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.22009	-118.497	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 240200 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13397	16041-10000-27412	12740 W ARROYO ST BUILD. A	91342	7	219B161   249	2525027014	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.29585	-118.41002	Plan check for T-24 only.  Remove indoor and outdoor HID fixtures and replace with new LED fixtures. Affected area: 51,883 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13398	17041-10000-41782	10930 W CHALON ROAD	90077	5	141B149    91	4369021009	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Expired	09/22/2023 12:00:00 AM	ADDRESS	34.08454	-118.45731	INSTALLING 4 TESLA 2.0 TO AN EXISTING SERVICE. TOTAL SIZE IS  23.2KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13399	12041-10000-30177	900 W TEMPLE ST BLDG B	90012	9	133-5A211  94	5161001043	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Apartment			12/14/2012 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.06063	-118.24976	"New 239 unit apartment building.  Five stiries of residential above 1 floor of commercial.  1 level of subterranean parking and 2 above grade.   A variance if filed for fire alarm.  BLDG ""B"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13400	18041-10000-09732	3850 W WILSHIRE BLVD	90010	10	132B193    82	5093005001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.06153	-118.31086	Plan check for Title 24 only in existing space retail on first floor and second floor is office space. Total area: 5075 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13401	11041-10000-00149	6021 N LAUREL CANYON BLVD	91606	2	177B165   671	2333013063	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM			Reviewed by Supervisor	02/24/2012 12:00:00 AM	ADDRESS	34.18008	-118.39671	11.8KS PHOTOVOLTAIC SYSTEM ON THE ROOF OF A PRIVATE SCHOOL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13402	16041-30000-35467	1150 N CAHUENGA BLVD	90038	13	144B185   521	5533008002	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			10/06/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.09215	-118.3287	Installation of fire alarm system in new 4 story 29 unit apartment building.  Total system size = 1 FACP + 123 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13403	13041-10000-06017	9301 N TAMPA AVE UNIT 192	91324	12	198B117    99	2761037004	R1-1	North Valley	Reseda - West Van Nuys	Tarzana		1133.01	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC FOR TITLE 24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT FOR RETAIL/MERCANTILE SPACE. SQUARE FOOTAGE IS 4561. NOTE: ALL PERMITS FOR TITLE 24 APPLICATIONS SHALL BE OBTAINED THROUGH ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13404	15041-20000-23251	5548 N IRONDALE AVE	91367	3	174B109   509	2151033084	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Expired	08/28/2017 12:00:00 AM	ADDRESS	34.17153	-118.58527	Addition of solar modules and inverter to existing roof mounted PV array.  Addition size = 3 kWac.  Total system size = 9 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13405	19041-20000-32856	5430 N SATSUMA AVE	91601	2	174B173  1333	2416015002	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.16958	-118.3674	POWER AND ENERGY PLAN CHECK FOR NEW 800A 120/240 V 3 PHASE SERVICE. SCOPE OF WORK INCLUDES PANELS, EQUIPMENTS AND LIGHTS. TOTAL SQUARE FOOTAGE = 96581 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13406	09041-20002-05299	1726 N GOWER ST	90028	13	148-5A189  86	5545002900	C4-1-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Apartment			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.10253	-118.32216	REVISION TO APPROVED PLANS. CHANGES ARE CLOUDED ON PLANS TO SHOW INVERTER PANEL, 800A BUS FROM MAIN, AND 1200A C/B SECTION ON MM1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13407	16041-10000-42232	9320 S LINCOLN BLVD	90045	11	096B161   862	4122022931	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	33.95601	-118.41515	NEW FIRE ALARM PANEL WITH 88 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13408	13041-10000-28360	1446 N DEVLIN DR	90069	4	147B169   855	5560001020	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM			Reviewed by Supervisor	10/21/2013 12:00:00 AM	ADDRESS	34.09575	-118.38711	RESUBMITTING EXPIRED PREVIOUSLY  APPROVED PLANS 10041-20000-15221. PLAN CHECK UNDER 2008 NEC/  2010 CEC.NOTE FROM PREVIOUS PLAN CHECK: Plan check for new single family dwelling with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13409	11041-10000-06663	1010 W MARTIN LUTHER KING, JR BLVD	90037	9	114B197   265	5020029026	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM			Corrections Issued	04/10/2011 12:00:00 AM	ADDRESS	34.01067	-118.29205	INSTALL COMPRESSED NATURAL GAS (CNG) FUELING DISPENSER & EQUIPMENT AT EXISTING GAS STATION. NEW 600 AMP SERVICE, PANEL, AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13410	19041-20001-32288	8406 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM				10-2019 Changes to an approved set of plan, Changes include relocate PV disconnect. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13411	17041-10000-15779	1901 S AVENUE OF THE STARS #1200	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.05949	-118.41705	PC FOR ENERGY. TENANT IMPROVEMENT OF SUITE 1200, REPLACING EXSITING LIGHTS WITH LED LIGHTS. TOTAL AREA 2920 SQ FT.B 17016-10000-08825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13412	19041-10000-18636	144 N BRISTOL AVE	90049	11	132B137   341	4405020007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.05794	-118.48823	PLAN CHECK FOR A ROOF MOUNTED 11.34KVA PV SYSTEM CONSISTING OF 36 (SUNPOWER X22-370) AC MODULES CONNECTED TO EXISTING 600A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13413	13041-10000-27321	202 N GRAMERCY PL	90004	4	138B193   763	5516020011	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM			Reviewed by Supervisor	10/18/2013 12:00:00 AM	ADDRESS	34.07484	-118.31233	PV1 , ROOF-MOUNTED SOLAR ARRAY OF A 4.9 KW DC PV SYSTEM IN A 2-STORY HOME. ENPHASE 215-60-2LL-S22-NA MICRO-INVERTERS ON A NON-STANDARD PLAN WITH 20 MODULES (HANWHA HSL 60, 245W MODULE )	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13414	14041-10000-32360	815 W COLORADO BLVD	90041	14	163-5A231 107	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.14051	-118.18382	Energy plan check for a bank, Firefighters First Credit Union, T.I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13415	19041-10000-08259	11141 W OSBORNE ST	91342	7	213B173    45	2529028007	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.24	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.2802	-118.37362	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13416	15041-20000-28830	9742 N MARCUS LANE	91042	7	201A201   296	2564016032	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.24543	-118.28234	Plan check for PV roof mounted system. System size: 4.2kW with 21 modules and 1 inverter(4.2kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13417	15041-10000-22421	207 S BROADWAY 7 TH FLR	90012	14	130-5A213  23	5149009022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.05231	-118.24703	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN THE 7TH FLOOR.  TOTAL SQUARE FOOTAGE 6590.  PLAN CHECK FOE ENERGY AND EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13418	13041-10002-35195	888 S HOPE ST	90017	14	127-5A209  28	5144020027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			12/19/2013 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Closed	10/18/2018 12:00:00 AM	ADDRESS	34.0452	-118.25996	THIS APPLICATION IS COLLECT PLAN CHECK AND PERMIT FEES ONLY. ALL APPROVALS HAVE BEEN COMPLETED UNDER MASTER PERMITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13419	10041-10000-16867	1293 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.05147	-118.22511	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13420	14041-20001-06440	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	((change to previuosly approved set of plans. changes covered under delta 12 clouded. ))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13421	18041-20001-22399	515 S FIGUEROA ST 17th FLR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Approved	08/31/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	Revisions to approved set of plans.  Lighting design changes.  (((Ti for corridoors and restyrooms  17th floor of a high rise bldg.Title 24 and emergency lighting.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13422	19041-20000-52762	5450 N VESPER AVE	91411	4	174B149  1235	2249003022	[Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.16939	-118.4507	Installation of lights and outlets in common areas.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13423	17041-10001-01071	10906 N LAUREL CANYON BLVD	91340	7	210B153  1096	2616011***	(Q)RD2-1-O-CUGU, RD2-1, T, Q	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.26863	-118.44228	OFF-HOUR PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13424	18041-20000-24338	9005 W EXPOSITION BLVD	90034	5	120B169    49	4312013029	M1-1	West Los Angeles	West Los Angeles	South Robertson		2701.00	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	08/02/2022 12:00:00 AM	ADDRESS	34.02864	-118.3922	New 4-story office building.  New 800A 240D/120V 3ph-4w service supplying the new structure as well as (E) adjacent warehouse building.Building permit issued under 15010-30000-03952.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13425	11041-20000-04707	3610 W VALLEYBRINK ROAD	90039	13	153A207    31	5435028017	[Q]C1.5-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Finaled	05/24/2011 12:00:00 AM	ADDRESS	34.11548	-118.26421	T.I. to existing space.  Install general/emergency lighting in lockroom area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13426	19041-20000-23827	10800 W PICO BLVD	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	10/13/2021 12:00:00 AM	ADDRESS	34.04054	-118.4272	Full PC for power and energy. Scope includes three new 5000 Amp 277/480V 3 phase 4 wire services/Distribution boards, new panels, new circuits, new lights. Total affected area is 434,877 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13427	11041-10000-19078	438 S MAIN ST	90013	14	129A211   137	5148009013	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM			PC Approved	09/08/2011 12:00:00 AM	ADDRESS	34.04716	-118.24785	REMODEL EXIST. SPACE  FOR A NEW RESTAURANT/JUICE BAR (GREEN T'S)PLAN CHECK  FOR T-24 LIGHTING COMPLIANCE AND EMERGENCY LIGHTING.INSPECTION PERMIT PREVIOUSLY ISSUED UNDER PCIS 11041-10000-15403.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13428	11041-20004-01877	330 S LA CIENEGA BLVD	90048	5	138B173   831	5511032047	C2-1VL-O, P-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.07282	-118.37627	revision 4 change fixture type k to maximum 150 watts only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13429	19041-10000-07168	1011 N NORTH BROADWAY	90012	1	136-5A215 135	5414017024	C2-2D	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.06721	-118.23571	REMOVE HID FIXTURES AND REPLAVE WITH NEW LED FIXTURES (OUTDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13430	13041-20002-23698	9301 N TAMPA AVE SPACE# 171	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Modification to approved set due to revisions in Teavana's prototypical store layout.  Removal of floor outlets, outlet heights modified, switch bank relocation, and miscellaneous minor changes.  Note: Permit is under a 14041-20000-08802(((TITLE-24 ONLY PC. CHANGE OF USE FROM  RETAIL TO TAKE-OUT RESTAURANT.  TENANT IMPROVEMENT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13431	11041-10000-09191	940 N WESTERN AVE E	90732	13, 15	144B193  1234	5535021020	(Q)C2-1XL, C4-1D	Central, Harbor	Hollywood, San Pedro	Hollywood Studio District, Northwest San Pedro	YES	1916.10, 2963.00, 2964.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	08/03/2012 12:00:00 AM	ADDRESS	33.75105	-118.30881	TI TO AN EXISTING RESTAURANT.  T-24 WITH EMERGENCY LIGHTING ONLY.  OTC PLAN CHECK.  COMPLY WITH DEPARTMENT ORDER effective date 03/16/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.  COMPLETE ELECTRICAL PLAN CHECK MAY BE REQUIRED SUBJECT TO FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13432	18041-10000-16036	843 N WILCOX AVE	90038	4	141B185    62	5533026024	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.08647	-118.33126	Plan check for a new fire alarm system for a 4-story, 8-unit apartment building. Scope include (1) fire alarm panel, (1) power supply and (67) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13433	14041-10000-21130	501 W EL SEGUNDO BLVD	90044	15	081B201   259	6132002020	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	PIN	33.91663801	-118.28317828	PC for methene gas detection system for a commercial building. 1 panel,  18 fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13434	18041-20001-00601	12144 W LA MAIDA ST	91607	2	168B165   426	2356008003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.15841	-118.39803	EXPEDITE PER APPLICANTS REQUEST. PV1. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.16 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13435	15041-10000-07190	1070 N SOMERA ROAD	90077	5	144B149   166	4369032017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.09151	-118.45886	Fee is $0.00 due to senate bill 1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2KW INTERCONNECTED WITH MSP. Work includes (1) ABB PVI 6000-OUTD  and (1)ABB PVI 4.2-OUTD inverters,  and (45) Kyocera KU2556XCA modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13436	18041-20001-29310	23810 W ALBERS ST	91367	3	171B089    39	2047008018	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM			PC Approved	08/13/2018 12:00:00 AM	ADDRESS	34.16857	-118.64522	Expedite per applicant requestPlan check for PV roof mounted system, sysem size: 10.56kW with 32 pv modules and 32microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13437	14041-20000-34170	289 N HOMEWOOD ROAD	90049	11	135B141   802	4403002008	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.06277	-118.48298	SFD SERVICE UPGRADE 600AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13438	15041-10000-16714	10526 N PLAINVIEW AVE	91042	7	207B197  1357	2557022006	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Expired	07/04/2017 12:00:00 AM	ADDRESS	34.26034	-118.29779	PV1.  Install 9.88 kW rooftop-mounted, utility-interactive PV system w/ 125A load center.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13439	19041-10000-53231	7105 W SUNSET BLVD	90046	4	147B181   638	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	12/22/2021 12:00:00 AM		Issued	12/22/2021 12:00:00 AM	ADDRESS	34.09814	-118.34455	PLAN CHECK FOR TITLE 24 ONLY. SCOPE OF WORK INCLUDES ALTERNATIONS TO LIGHTING FIXTURES AND NEW CIRCUITS FOR AN EXISTING TI. TOTAL AFFECTED AREA: 1381 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13440	19041-10001-20324	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM			PC Info Complete	11/07/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLAN CHECK FOR CHANGES TO APPROVED SET. SCOPE OF WORK INCLUDES REVISING INTERIOR AND EXTERIOR LIGHTING, TITLE 24 FORMS HAVE BEEN UPDATED. ALL CHANGES ARE CLOUDED UNDER DELTA ONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13441	10041-20000-20801	526-536 E 5TH ST	90013	14	127-5A213 300	5147025020	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	05/06/2011 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.04355	-118.24318	Plan check for new installation of photovoltaic system for each service in building. Building supplied from (5) existing service from utility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13442	17041-10000-42641	3434 E PERCY ST	90023	14	121-5A227  81	5188004028	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Issued	11/28/2017 12:00:00 AM	ADDRESS	34.02823	-118.1992	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13443	18041-10000-00655	9624 N KEOKUK AVE	91311	12	201B113   869	2748028042	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.24473	-118.57437	PC FOR ROOF MOUNTED PV ON SFD. PART OF COMMUNITY PROJECT IN COUNJUCTION WITH DWP. SYSTEM SIZE 3.92KWACSCOPE INCLUEDS 14 MODULES WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13444	16041-30001-30894	4145 N STANSBURY AVE	91423	4	165B153   914	2266012019	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM			PC Approved	09/23/2016 12:00:00 AM	ADDRESS	34.1457	-118.44128	Plan check for PV roof mounted system. System size: 12.2kW with 54 modules and 3 inverters(3.6kW, 3.6kW and 5.0kW) connected to MSB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13445	16041-10000-43923	14803 S ESTRELLA AVE	90248	15	075B201   225	6119012053	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	33.89779	-118.28585	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(18)MODULES-SOLARWORLDSW290 MONO(1)INVERTER-NINGBO GINLONG SOLIS-5K-2G-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13446	15041-10000-38371	3833 S DUNN DR 1-40	90232	5	120B165  1292	4207005008	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			11/13/2015 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.02201	-118.39919	PC FOR A NEW 40 UNITS APARTMENT BUILDING, 6-STORY, 2 LEVEL PARKING GARAGE. TOTAL AREA 24874 SQ INDOOR+ 3423.924 SQ FT OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13447	15041-20000-11736	6256 N TOPANGA CANYON BLVD C-1200	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	TI to new commercial building (restaurant). Plan check for power and energy.  Total Sqft. 2235.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13448	14041-20000-18062	19871 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Closed	02/16/2016 12:00:00 AM	ADDRESS	34.23203	-118.56649	TI for a commercial building with new 1200 amp main switch gear, 150KVA transformer, and 800 amp Distribution panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13449	17041-10000-24700	1395 N VINE ST BLG D	90028	13	147A187   348	5546016022	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Closed	07/15/2020 12:00:00 AM				PC FOR TEMP POWER FOR A  MULTIPLE BUILIDINGS SITE FOR CORE AND SHELL CONSTRUCTION. SCOPE INCLUDES 2 TEMP-SERVICES OF 1600A 480/277FOR SPIDER BOXES, TEMP CONSTRUCTIONS CONTAINERS, CRANES, MANLIFTS AND POWER SKIDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13450	13041-10005-32351	1026 S BROADWAY BLDG A	90015	14	126A209   140	5139014006	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			07/28/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.04029	-118.25788	Changes to permitted set of plans: Meter Group 4 was removed and its loads  are supplied from the other MeterGroups with the number of apartments remaining the sameMeter group feeders are changed to CU	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13451	15041-20000-25656	21530 W OXNARD ST 1st Floor	91367	3	177B105    86	2146006031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM			PC Approved	08/07/2015 12:00:00 AM	ADDRESS	34.17896	-118.59871	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Luminaires are being replaced as modifications-in-place. Total lighting area = 600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13452	14041-10000-29255	22643 W VENTURA BLVD	91367	3	171B097   166	2040028010	C1.5-1VLD, C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM			PC Approved	10/22/2014 12:00:00 AM	PIN	34.16770476	-118.62042219	Title 24 plan check only.  Total area = 1,280 sq. ft.T.I. to existing domino's pizza.Partial Permit fees already under 14041-10000-24582 (20 branch circuits).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13453	18041-20000-36374	622 N LAS LOMAS AVE	90272	11	129B121   897	4414013012	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.04646	-118.53916	pv1install roof mounted pv system sized 9.6KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13454	17041-30000-29977	2601 S FIGUEROA ST	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.02804	-118.2763	Plan check for Title 24 only in existing space. T.I. to office space. Total area: 18998 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13455	13041-20001-23477	20454 W ROBERT PL	91364	3	168A111    29	2174017015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			Corrections Issued	01/29/2014 12:00:00 AM	ADDRESS	34.15631	-118.57906	(((CHANGES MADE TO APPROVED SET. NEW INVETER IS 7.5KWAC WITH AFCI CAPABILITIES AND USING COMBINER BOX)))PV1.  Install 9.00 kW DC roof-mounted solar array, interconnect with main service panel.  Solar PV Standard Electrical Plan	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13456	15041-10000-32591	7809 N BOTHWELL ROAD	91335	3	189B117   774	2105006016	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Expired	11/27/2017 12:00:00 AM	ADDRESS	34.21248	-118.56137	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.15KW INTERCONNECTED WITH MSP.(28) MODULES(2) INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13457	16041-10000-21278	4550 N VAN NUYS BLVD Ste. K	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	PC FOR Y-24 ONLY. CHANGE OF USE FROM RETAIL TO RESTAURANT. NEW ADDITIONAL LOAD < 400A. TOTAL AREA: 1,842 SQ.FTB# 16016-10000-14021	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13458	19041-20000-25249	7620 N RESEDA BLVD	91335	12	186B125   123	2119001041	[Q]C2-1VL-CDO, [Q]P-1VL-CDO, [Q]R3-1-CDO	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.20913	-118.53586	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13459	13041-10000-34156	8618 N SEPULVEDA BLVD	91343	6	195B145   601	2654021011	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.22711	-118.46747	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 3040SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13460	14041-10000-25794	3165 W 11TH ST 101-202	90006	10	129B193   562	5080009020	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.05094	-118.30825	Installing new fire alarm system. 26 devices 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13461	11041-20000-17877	7021 W HOLLYWOOD BLVD	90028	13	147B181   137	5548003020	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.1017	-118.34273	T24 ENERGY FOR NEW BAKERY SPACE IN A EXISTING MARKET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13462	17041-20001-15318	1317 N DELRESTO DR	90210	5	144B157   116	4356014021	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	34.09365	-118.42585	Revisions to approved set.  Changes and approval to SLD only.  Change of equipment and wiring configuration.  Approval for sheet E-0.3 only. (((Plan check for power only. Project site is an existing single-family dwelling. Project scope is a major addition and remodel with a new electrical distribution system.Note: Building permit has been pulled under 14014-30000-03699)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13463	09041-10002-11844	155 S MAIN ST	90012	14	130-5A213  24	5149001902	PF-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.05125	-118.24458	T24 lighting plan check for revised lighting system.   Using low voltage MR16 supplied by 100 watt transformers, and led lamps supplied by 96 watt drivers.  No change in the emergency lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13464	17041-10000-03469	1459-1459 1/2 W SUNSET BLVD	90026	13	139-5A211 161	5406001043	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			PC Info Complete	02/02/2017 12:00:00 AM	ADDRESS	34.07535	-118.25366	TI, RETAIL SPACE. NEW LIGHTING. PC FOR ENERGY ONLY, T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13465	12041-10001-05441	2515 S CENTRAL AVE	90011	9	118-5A209 348	5131026029	C2-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM			PC Approved	04/25/2012 12:00:00 AM	ADDRESS	34.0193	-118.25496	PLAN CHECK POWER ONLY FOR FIRST TIME TENANT (RETAIL) TO A MIXED USED BUILDING. T24 ENERGY PLAN CHECK APPROVED UNDER #12041-10000-05261. BUILDING ELECTRICAL CORE & SHELL UNDER #07041-10000-30732 (1011 E ADAMS BLVD.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13466	13041-20000-02651	10250 W SANTA MONICA BLVD 676	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGE OF USE FROM RETAIL TO SALON	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13467	19041-10000-17246	19161 S HARBORGATE WAY	90501	15	060B193   442	7351021044	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	06/18/2020 12:00:00 AM	ADDRESS	33.85627	-118.30374	"TI IN AN EXISTING COMMERCIAL AREA. CHANGE USE OF PORTION OF FIRST FLOOR FROM ""BREAK ROOM"" TO ""TEST KITCHEN"" AND OFFICE.  INSTALING NEW LIGHTS. T-24 ENERGY ONLY. TOTAL AREA: 1,400 SQR FT. BULDING PERMIT: 18014-20000-02583"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13468	14041-10000-10631	13148 W RAYMER ST	91605	2	186B157   305	2327001012	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.20563	-118.41964	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13469	10041-10000-25501	1026 W 34TH ST Lyons Ctr.	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	08/12/2011 12:00:00 AM	PIN	34.02400284	-118.2895744	Ti in the Lyons fitness center inside the USC. EPC is for T24 & Emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13470	11041-10002-26286	901 W OLYMPIC BLVD	90015	14	129A207   293	5138005036	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM			PC Info Complete	09/19/2012 12:00:00 AM	ADDRESS	34.04576	-118.26609	Suppl. Application for the changes to the original Plan check for power aNOTE:nd enery for new 23-story Marriot Hotel with 393 rooms.PLAN CHK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13471	15041-20000-35103	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM			PC Info Complete	11/18/2015 12:00:00 AM	ADDRESS	33.94955	-118.38214	PLANCHECK FOR POWER ONLY.  POWER DISTRIBUTION FOR NEW HVAC EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13472	10041-10000-08583	3250 W OLYMPIC BLVD	90006	10	129B193   288	5080009008	[Q]C2-2D	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	05/10/2010 12:00:00 AM		Permit Finaled	05/24/2010 12:00:00 AM	ADDRESS	34.05244	-118.30766	TI IN AN EXISTING COMMERCIAL AREA. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS. PERMIT IS FOR NEW CIRCUTS & LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13473	18041-20001-00515	2414 E MICHIGAN AVE	90033	14	127-5A223  81	5180002023	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			01/05/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.0449	-118.20834	Expedited plan check fee.PV2.  Reinstallation of 7.695 kW DC rated PV system for reroofing project.  (27) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13474	15041-10001-35837	11677 W SAN VICENTE BLVD STE-200	90049	11	132B145   497	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.05404	-118.46492	CHANGE TO APPROVED SET. RECHECK NEW FEEDER SIZE AND FAULT CURRENTS. CHANGES CLOUDED DELTA 10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13475	15041-10001-37884	701 E 3RD ST 2nd floor	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Expired	04/09/2018 12:00:00 AM	PIN	34.04581508	-118.23784015	"Changes on approved set, marked as ""Field Revision Delta-1 and Delta-2"":Adding  motor loads. Load changes on single line diagram and panel load schedule; However, it's still less than 400A.No changes on T-24 [Master plan was checked for T-24 only] <<TI TO 2ND FLOOR. PC FOR T24 ENERGY ONLY. NEW LIGHTING>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13476	15041-10000-30614	6540 W HOLLYWOOD BLVD	90028	13	148-5A187 184	5547016005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.10142	-118.33231	NEW FIRE ALARM SYSTEM 25 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13477	19041-10000-06956	1422 W 11TH ST	90015	1	129A205   312	5137024213	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.04661	-118.27321	"PC FOR MEDICAL TENANT IMPROVEMENT FOR NEW DIALYSIS CLINIC IN EXISTING VACANT SHELL , 13090 SF. NO EXTERIOR WORK. OSHPD 3 COMPLIANCE.SCOPE INCLUDES NEW PANELS, EQUIPMENT AND CIRCUITS WITH LIGHTS. T24 EXEMPT AS OCCUPANCY TYPE ""I"" UNDER 2016 CODEb# 18016-10000-26120e core and shell - 19041-10000-22493"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13478	19041-10000-45792	5630 S HOOVER ST	90037	9	108B201  1094	5001019033	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Voices		2327.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	33.99074	-118.28693	REMOVE HID FIXTURES AND REPLACE WITH LED FIXTURES- T/24 ONLY  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13479	12041-20000-30591	2600 N PARK OAK DR	90068	4	153B193    42	5580030035	RE15-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2012 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.11838	-118.31334	PV-1. Plan check for pv system. Transformerless inverter. 4.41kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13480	14041-10000-03918	10375 W GLENBARR AVE	90064	5	126B161   221	4318032004	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.04029	-118.41016	PV1. ROOFMOUNTED SOLARSYSTEM. NEGATIVELY GROUNDED SYSTEM. SYSTEM SIZE: 10KW.(40) RENESOLA JC250 (2) SMA SB5000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13481	19041-20001-52812	10049 W TOLUCA LAKE AVE	91602	4	165B181   312	2424026011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	01/28/2020 12:00:00 AM	ADDRESS	34.14861	-118.34937	Expedited plan check fee.PV1.  Install 11.34 kW roof mounted PV system and 40.5 kWh energy storage system.  (36) modules with 10 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13482	14041-10000-35798	3602-3604 W 3RD ST	90020	10	135B197   178	5502006021	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Issued	12/29/2014 12:00:00 AM	ADDRESS	34.06889	-118.29449	TENANT IMPROVEMENT TO 1 STORY 6653 SF  EXISTING RETAIL SHOPS; CREATE NEW RESTROOMS TO ALL TENANT SPACES.  PLAN CHECK FOR ENERGY FOR NEW LIGHTING SYSTEMS IN EACH TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13483	17041-10000-38274	556 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   617	2424044***	[Q]C2-1-SN	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Issued	11/01/2017 12:00:00 AM	PIN	34.1389546	-118.35816043	INSTALLATION OF OUTDOOR LED POLE-MOUNTED LUMINAIRES FOR A PARKING LOT PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13484	19041-20000-22691	9758 N ABREGO CT LOT 14	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.24756	-118.45053	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13485	14041-10000-30247	3517 W SUNSET BLVD	90026	13	144A203   174	5429024002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.08931	-118.27647	Title 24 plan check only.  Total area = 1,606 sq. ft.T.I. To existing retail space including new lighting, recepticles, and a 100A panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13486	10041-10000-25193	8358 W FOOTHILL BLVD	91040	2	204B189    39	2560007003	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	01/05/2011 12:00:00 AM		Permit Finaled	04/08/2011 12:00:00 AM	ADDRESS	34.25953	-118.31549	CHANGE OF USE FROM RETAIL TO BAKERY AND PROVIDE (N) ADA RESTROOM; PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13487	19041-20000-36675	4960 E HUNTINGTON DR SOUTH Ste 103-105	90032	14	144A235   333	5218009020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM			PC Info Complete	09/13/2019 12:00:00 AM	ADDRESS	34.08745	-118.17453	Power and lighting for first-time tenants to (3) commercial shell spaces.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13488	18041-10000-01750	7043-7047 N JORDAN AVE	91303	3	183B105   495	2138003019	(T)(Q)R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			01/30/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.19858	-118.60298	Full plan check for a new 33-unit, 4-story apartment over one basement parking garage.B#17010-20000-02093	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13489	15041-10000-41982	5830 S MCCONNELL AVE BLDG #1	90094	11	102B161  1270	4211037026	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	33.97471	-118.41717	fa system apartment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13490	19041-20000-06292	21600 W OXNARD ST STE 400/-450/460	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Issued	02/21/2019 12:00:00 AM	ADDRESS	34.179	-118.6002	T24 PLAN CHECK FOR EXISTING COMMERCIAL OFFICE REMODEL. NEW LIGHTS ONLY ON EXISTING CIRCUITS. TOTAL SQUARE FOOTAGE = 6,441 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13491	18041-10000-34912	4470 N WINNETKA AVE	91364	3	165B113    20	2174026008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Issued	09/20/2018 12:00:00 AM	ADDRESS	34.15251	-118.57107	PLAN CHECK FOR ROOF MOUNTED 11.4KVA/13.75WDC PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE 11400A-US) WITH 50 MODULES USING P320 OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13492	13041-20000-27348	9950 N WOODWARD AVE	91040	7	201B193   162	2562001010	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.24998	-118.3064	PV1 GROUND MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE10KWAC. 44 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13493	17041-20001-09814	939 S THAYER AVE	90024	5	135B153   391	4360017028	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Expired	03/04/2024 12:00:00 AM	ADDRESS	34.06468	-118.43397	5.4.2017 - Plan check for modifications to approved set. Add two modules and two microinverters to system. Only change.=======PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.36 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13494	14041-20000-26746	15853 W MONTE ST 103, 104	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.31022	-118.47637	PC ONLY FOR UPDATED LOAD CALC FOR SINGLE LINE DIAGRAM.PER INSPECTOR REQUEST, PEAK DEMAND PROVIDED FROM UTILITY TO VERIFY LOAD ON EXISTING SERVICE BOARD. PC ONLY. POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13495	18041-10001-37757	914 E 31ST ST	90011	9	117A209   109	5114021043	(Q)M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.01573	-118.25941	expedited feesNEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (660) MODULES, (6) 33.3KW INVERTERS AND (330) POWER OPTIMIZERS P700. TOTAL SYSTEM SIZE IS  199.8KWAC/217.8KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13496	17041-20000-28023	14925 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29448	-118.4561	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13497	14041-20000-17525	4537 N TENANGO DR	91364	3	165B113    16	2174025023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.15235	-118.57355	PV1.  Install 13.52 kW roof-mounted, utility-interactive PV system.  (2) transformerless inverters.$0 permit fee is due to state bill SB-1222 re: solar permit caps.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13498	14041-10000-29516	6614 W HOLLYWOOD BLVD	90028	13	148-5A185 130	5547015013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.10141	-118.33371	Change of use to joint living and work quarters. Energy plan check for 1st floor recording studio	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13499	18041-20000-29892	3108 S CAVENDISH DR	90064	5	123B165   274	4316009007	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.0356	-118.40607	PV1.  Install 13.2 kW DC/10.56 kW AC roof mounted grid tied PV system.  (44) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13500	12041-10006-14793	220 E 2ND ST 1-104	90012	9	130-5A213 203	5161024014	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			05/28/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.04978	-118.2429	Encase fire pump conductors. include all power destribution singlr	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13501	13041-10000-28774	9157 N WILLIS AVE	91402	6	198B149   444	2651006027	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.23726	-118.45538	PV1, Plan check for roof mounted 5.25 KW DC Photovoltaic system transformerless inverter(21) TRINA SOLAR # TSM- 250PA05.18\(1) POWER-ONE # AURORA PVI-4.2-OUTD_S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13502	12041-20000-07599	2817 E CESAR E CHAVEZ AVE	90033	14	127-5A225 102	5178019004	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.04431	-118.20175	Remodel, change of use from retail to laundromat. Plan check for power and energy. 4140 conditioned sqft. Single story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13503	13041-20000-27355	2048 N KENILWORTH AVE	90039	4	147A205   325	5431018019	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.09624	-118.26869	pv1 single family dwelling. total system size 3.4 kw AC using 16 modules. using enphase microinverter. standard plan. PER APPLICANT. NEW APPLICATION GENERATED FOR SYSTEM OF 16 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13504	17041-10001-23838	10000 S WESTERN AVE	90047	8	091-5A193  74	6059001033	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	33.94524	-118.30881	Expedite FeesPV2, NEW ROOF SOLAR SYSTEM IN A 2 STORY BUILDING USING CENTRAL INVERTERS. (2) SOLAREDGE INVERTERS 20K AND 33.3K, (156) CANADIAN SOLAR MODULES AND (78) OPTIMIZERS. TOTAL SYSTEM 53.3Kac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13505	17041-10000-42324	11904 W TENNESSEE PL	90064	11	123B149   896	4259033002	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.03044	-118.44985	PC for new rooftop solar for 3kW system connected with battery backup(5kW). Installing 10 modules with ABB central inverter, new 225A load center and new backup battery (battery under permit 17041-10003-42324).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13506	15041-20001-11268	10825 W ROSE AVE	90034	5	120B161   598	4254017034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.02537	-118.41643	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 14 kWac and consists of (66) modules, (2) inverters, and (1) 100-amp load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13507	13041-20000-21418	617 W 7TH ST 12th Floor	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	ADDRESS	34.04779	-118.2571	T24 FOR EXISTING OFFICE SPACE. 14150 SQRFT. SCOPE OF WORK ON THE ENTIRE 12TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13508	17041-20001-41458	1333 S BEVERLY GREEN DR 1-4	90035	5	129B165   130	4330004010	[Q]RD2-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			07/23/2018 12:00:00 AM			PC Approved	07/23/2018 12:00:00 AM	ADDRESS	34.05319	-118.40537	Revisions to approved set of plans - approval for service conductor routing detail changes only. (((Plan check for power and energy. Project site is a new 2-story, 4-unit apartment building. Work includes a new 600-amp service and a total lighting area of 6,336 sq. ft.Note: Building application has been generated under 17010-30000-00174)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13509	11041-10000-06055	7112 N OWENSMOUTH AVE	91303	3	183B105   355	2111026018	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			Verifications in Progress	05/24/2011 12:00:00 AM	ADDRESS	34.19964	-118.6014	PROPOSED 2-STORY ADDITION CONTAINING 6-UNITS CONNECTED TO (E) 1-STORY, FOUR UNIT APARTMENT BUILDING.  TOTAL OF 10 UNITS FOR WOMEN SHELTER. NEW 600 Amp SERVICE, PANEL BOARDS AND CIRCUITS. EPC IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13510	11041-10000-25001	10250 W SANTA MONICA BLVD #121	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to an existing sunglass store in the Century City Mall, space121.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13511	14041-10001-12635	20822 S DALTON AVE	90501	15	054B193   492	7351024025	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	33.84124	-118.30269	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.57 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER. TRANSFORMERLESS INVERTERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13512	18041-20000-37825	10345 W OLYMPIC BLVD 2ND FLR	90064	5	129B161   136	4319006052	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.05186	-118.41853	Plan check for power and energy for T.I. to office space Total newly connected load exceed 400A Total area: 23,060 sq ft. B#18016-10000-31817	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13513	18041-30000-05745	3835 S CLARINGTON AVE #508	90232	5	120B165  1350	4208002018	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Issued	02/15/2018 12:00:00 AM	ADDRESS	34.02163	-118.39979	Plan check for new Fire Alarms system in Child Care Building. Total Fire alarm devices: 67 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13514	17041-10001-32823	10900 W WILSHIRE BLVD 10,11,14th-floors	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.05848	-118.44419	09/19/2017Changes to an approved set of plans, changes include the revision of floor numbers and lighting layout. Under delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13515	09041-10001-13263	1513 S GRAND AVE	90015	9	124-5A207 123	5134015020	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Public Safety Only			02/02/2010 12:00:00 AM	02/02/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	34.03622	-118.26632	PLAN CHECK FOR REVISION TO APPROVED PLANS INDICATED DELTA 1 & 2 ON PLANS.  ADDITIONAL DEVICES ADDED AND REPLACING FACP PANEL.  FIRE ALARM SYSTEM FOR THE CORE AND SHELL OF A 4-STORIES MEDICAL OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13516	14041-10001-09094	2756 S DUMFRIES ROAD	90064	5	126B161   509	4318016011	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.03858	-118.41471	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE3000A-US-ZB-U.(10) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13517	17041-20001-45572	17020 W ESCALON DR	91436	5	162B133   205	2287003034	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			Reviewed by Supervisor	12/26/2017 12:00:00 AM	ADDRESS	34.13944	-118.50254	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array for SFD.10.4kW ungrounded system. (2) 5.2kW inverters.(36) 300W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13518	19041-20001-02282	3720 N LITCHFIELD LANE	91356	3	162B117   401	2177043011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM			No Progress	01/29/2019 12:00:00 AM	ADDRESS	34.13655	-118.55193	Expedite per applicant request. Plan check for PV roof mounted system, sytem size: 21.17KW DC, 19.00KW AC with 73 PV Modules and 2 inverters(7.6KW and 11.4KW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13519	19041-10000-47043	2909 W EXPOSITION PL BLDG 13	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Closed	06/18/2020 12:00:00 AM	ADDRESS	34.02046	-118.32803	NEW FIRE ALARM SYSTEM IN A NEW THREE-STORY, 5-UNIT APARTMENT BUILDING (BLDG 13)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13520	14041-10000-02942	550 S HOPE ST # 510	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLANCHECK FOR T24ENERGY. OFFICE TI. SUITE 510. 1055 SF, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13521	18041-20000-36575	9131 N OAKDALE AVE	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.23697	-118.56716	ti to an existing commercial building. adding new lighting new controls to exisitng panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13522	11041-10000-07742	1430 S FAIRFAX AVE	90019	10	129B177   465	5068022043	(T)(Q)C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM			PC Info Complete	08/17/2011 12:00:00 AM	ADDRESS	34.05038	-118.36661	New VONS store with parking structure. New 2000 Amp service, board & branch circuits. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13523	16041-30001-20838	3383 N CANTON WAY	91604	2	159B169   273	2377017029	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.13362	-118.38527	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (59) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13524	15041-10000-27155	4677 E WORTH ST	90032	14	135A233   328	5223002016	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	PIN	34.06255797	-118.18127172	PC for energyonly, T-24 for a commercial werehouse. The scope of work includes the addition of receptacles, and light fixtures. 1 new panel (400 amps).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13525	19041-20000-40073	105 S FAIRFAX AVE	90036	5	138B177   597	5511025032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.07398	-118.36162	NEW METHANE MITIGATION SYSTEM ON NEW MIXED USE:  45 UNIT APARTMENT BUILDING 3-STORY TYPE V A  OVER COMMERCIAL OF TYPE I CONSTRUCTION FULLY SPRINKLERED. R-2 24956 SF/S-2 19,523 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13526	19041-20000-51189	13050 W FILMORE ST	91331	7	210B161   133	2533009003	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.27494	-118.417	PV1. INSTALL 3.10 KW DC PV SYSTEM WITH (10) MODULES/OPTIMIZERS AND (1) INVERTER (SE3800)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13527	17041-10000-43366	1888 S CENTURY PARK EAST	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	02/27/2018 12:00:00 AM		Issued	02/27/2018 12:00:00 AM	ADDRESS	34.06104	-118.41402	NEW FIRE ALARM SYSTEM TI . SCOPE INCLUDES ONE FIRE ALARM PANEL, 3 CONTROL PANELS AND 542 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13528	10041-20000-22057	635 W 35TH ST Basement	90089	8	120A201    89	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	PIN	34.0210213	-118.28127755	Install general/emergency lighting in mechanical room at basement.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13529	15041-10000-08368	600 WORLD WAY TERM 6-CONCOURS	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	ON CONCOURSE LEV OF TERMINAL 6, DEVELOPING OPEN SPACE AS RETAIL STOREPLAN CHK IS FOR POWER AND TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13530	19041-10000-02999	11668 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.20103	-118.38683	T24 PLAN CHECK FOR EXTERIOR LIGHTING FOR TISSUE TESTING LAB, TOTAL SQUARE FOOTAGE = 22661	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13531	17041-20000-04950	430 S BROADWAY	90013	14	129A211    57	5149024008	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.04864	-118.24991	Facade lighting for commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13532	18041-20000-35858	11740 W VANOWEN ST	91605	2	180B169    44	2322015010	R1-1, R3-1	South Valley	North Hollywood - Valley Village	NoHo		1232.03	Electrical	Electrical	Apartment			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.19379	-118.38943	Fire alarm system for new 11-unit 2-story apartment building.  (51) signaling and notification devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13533	12041-10000-11224	1900 W SLAUSON AVE	90047	8	108B193  1524	6001001021	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00, 2372.00	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	33.98892	-118.31175	PLAN CHECK POWER AND ENERGY FOR REMODELING OF EXISTING MCDONALD'S RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13534	15041-10000-43349	201 N FIGUEROA ST 9TH FL	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	IMPROVEMENTS IN OFFICE AREAS ON THE 9TH FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13535	18041-10001-25475	2700 S FIGUEROA ST	90007	9	121-5A203  98	5123018033	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.02708	-118.27647	DELTA 4 CHANGES TO APPROVED PLANS FOR CHANGES TO THE LIGHT DESIGN.<<<<Full PC for a First time tenant to space, New Restaurant. Scope of work includes new panel, new lighting and receptacles. Total sq. ft. 4063.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13536	18041-20002-35639	2917 W TEMPLE ST	90026	13	139-5A203 445	5156014010	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village	YES	1958.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	01/18/2019 12:00:00 AM	ADDRESS	34.07449	-118.27896	Revisions to approved set of plans.  Revised location of PV production meter.  $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414. (((Plan check for a PV2 roof-mounted PV system. System size is 21.08 kWdc/20 kWac and consists of (2) inverters, (62) modules, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13537	17041-20000-38561	6367 N VAN NUYS BLVD	91401	6	180B149   936	2241004003	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.18626	-118.44902	Plan check for energy only. TI to existing commercial building. Converting existing mezzanine to 2nd floor offices. New lighting (incl. emergency) - 4,220sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13538	16041-10001-00596	2055 N FIGUEROA ST Store 6689	90065	1	142-5A219 495	5446013057	PF-1, UC(CA)	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.08273	-118.22429	10/06/16Changes to an approved set of plans. All changes are clouded under delta 6. Changes include adding a neutral conductor for the power distribution section (PDS, 3wire to 4 wire system), and adding customer meter on the single line diagram. ((((New 210KW fuel cell system, interconnected to (E) service 277/408V. Fuel cell utility interactive.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13539	18041-30000-11439	19524-19534 W ASTOR PL 19524 HSE	91324	12	198B117   258	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.23715	-118.55857	PLAN CHECK FOR POWER ONLY IN 6 NEW TOWN HOMES WITH ATTACHED GARAGE. SERVICE SIZE: 600A b#17010-30000-01982	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13540	19041-10000-42129	4905 W HOLLYWOOD BLVD	90027	4	147B197   191	5589038052	C2-1D	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.10198	-118.29645	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 7058 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13541	11041-10001-07563	1700 E CESAR E CHAVEZ AVE Ste 1400	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2035.00	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.05093	-118.21753	CHANGES TO PERMITTED SET OF PLANS-NEW CIRCUITS AND PANELS RELOCATED TO NEARBY ELECTRICAL ROOM(((((((((T.I.  NEW TENANT WITHIN THE WHITE MEMORIAL MEDICAL OFFICE BUILDING.  BEING TURNED INTO AN ORTHOPEDICS MEDICAL OFFICE SUITE 1400.  FULL PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13542	16041-20001-21186	10357 W DIAMOND ST LOT 3	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13543	14041-20001-05208	12801 W NORTH SEAGLASS CIR	90094	11	102B161  1224	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97509	-118.41784	(((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING 9 MODULES AND TRANSFORMERLESS INVERTER. NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13544	18041-10000-01940	5850 S VERMONT AVE Tenant A	90044	9	105B197    72	6004001024	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	33.98773	-118.29129	PC for power and energy for first time tenant build out of DD's store. Installing four new panels, new lights, receptacles and equipment. Total area is 20,291sqft. B# 18016-10000-01656.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13545	14041-20001-00049	18318 W BLYTHE ST	91335	12	189B125   468	2102015050	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	ADDRESS	34.21463	-118.5323	(((EXPEDITE)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8 KW AC USING 30 MODULES. 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13546	18041-10000-17366	9145 N CORBIN AVE	91324	12	198B117   191	2761001087	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.23677	-118.56249	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13547	15041-10000-03037	812 S GRAND AVE	90014	14	127-5A209  24	5144019025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	PIN	34.04527178	-118.25793792	PC FOR POWER AND ENERGY. NEW 4 STORY PARKING STRUCTURE WITH SHELL TENANT SPACE AT GROUND LEVEL, DRUG STORE. TOTAL AREA  65569 SQ FT. NON HIGH RISE BUILDING.PLAN CHECKER TO VERIFY THE ISSUE WITH 14041-20000-098765.B# 15010-10000-00375.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13548	14041-20000-02278	15756 W COVELLO ST	91406	6	186B141   191	2206014016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Expired	04/05/2016 12:00:00 AM	ADDRESS	34.20743	-118.47687	PV1 TRANSFORMERLESS SYSTEM. USING SOLAREDGE TOTAL SYSTEM SIZE 4.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13549	13041-20000-21894	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	EXISTING RETAIL TO NEW RETAIL. TI. PC FOR T24 ENERGY ONLY. TOTAL AREA 6150 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13550	17041-10000-04432	2029 S SANTA FE AVE	90021	14	118-5A217  58	5167012036	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.02028	-118.23042	PC for Indoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 2,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13551	18041-10000-03920	3741 S CRENSHAW BLVD	90016	10	117B185  1309	5046024026	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.0187	-118.33556	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13552	18041-10000-10985	767 S ALAMEDA ST BLDG2-3RD FL COR	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	ALTERATIONS IN CORRIDOR ON 3RD FLOOR OF BUILDING 2PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13553	14041-20000-01476	2616 S SAN PEDRO ST	90011	9	118-5A207   9	5128017026	[Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.02098	-118.26147	NEW LAUNDRY MAT. SERVICE SIZE 800A. BUILDING PERMIT SUBMITTED IN 2013	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13554	16041-10000-18796	2939 W LEEWARD AVE 1-80	90005	1	132B197   276	5077016017	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.05886	-118.28782	NEW 80 UNIT APARTMENT BUILDING WITH 13 TYPICAL UNITS. 5 STORIES. NEW 2500 A UNDERGROUND SERVICE. FLOOR AREA OF 99208 SQFT. LOCATED IN METHANE HARZARD ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13555	19041-10000-52965	6950 N RESEDA BLVD	91335	3	183B125   618	2125009020	[Q]C2-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.19724	-118.53583	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13556	17041-10000-21072	638 S BEACON ST	90731	15	015B201   171	7455026900	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			Corrections Issued	06/22/2017 12:00:00 AM	ADDRESS	33.73807	-118.28029	Title 24 plan check.  TI on 7th floor of existing historical highrise building.  Subpanels to remain existing with new lighting and receptacles.  Lighting area = 3,261 sq. ft.       Building permit #17016-40000-12520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13557	15041-20000-24798	14850 W OXNARD ST	91411	4	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.17924	-118.45706	PLANCHECK FOR T24 ENERGY.  MINOR INTERIOR REMODEL: RESTROOMS AND OUTDOOR LIGHTING. 1400 OUTDOOR SQFT, 122 SQFT INDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13558	14041-20000-02280	6153 N FENWOOD AVE	91367	3	177B093   379	2035014003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.18242	-118.63354	PV1 TRANSFORMERLESS SYSTEM. USING SOLAREDGE TOTAL SYSTEM SIZE 6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13559	13041-10000-26748	11800 N FOOTHILL BLVD	91040	7	210B165   540	2528002901	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District, Pacoima	YES	9800.21	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.273	-118.39313	PLAN CHECK FOR POWER AND ENERGY. NO CHANGE IN OCCUPANCY. CHANGE FROM CHILDRENS MUSEUM TO DISCOVERY SCIENCE MUSEUM. LOADS ON PANELS ARE TO BE DETERMINED IN THE FUTURE ( EXHIBITS ARE NOT BUILD YET; SEPERATE PLAN CHECK MIGHT BE REQUIRED FOR  EXHIBITS). ORIGINAL SET OF PLANS WILL BE DROPPED OFF. CANNOT DETERMINE IF TENANT IMPROVEMENT OR CHANGES TO APPROVED SET OF PLANS WITHOUT ORIGINAL APPROVED SET.INFO FROM BUILDING PERMIT: REMODEL EXISTING MUSEUM TENANT IMPROVEMENTS ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13560	15041-20000-36287	6320 N CANOGA AVE STE 1620 &-1625	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.18499	-118.59722	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING(OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 3385 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13561	10041-20000-24242	11055 W CUMPSTON ST	91601	2	174B173  1242	2350003009	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			12/06/2010 12:00:00 AM			PC Info Complete	10/21/2011 12:00:00 AM	ADDRESS	34.17012	-118.37213	Variance for plan check extension has been filed. Permit is on 10041-20001-24242. PLAN CHECK FOR NEW 25 UNIT APARTMENT BUILDING WITH 1600A SERVICE. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13562	11041-10000-04141	6303 N OWENSMOUTH AVE 5th-floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	06/23/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI IN AN EXISTING OFFICE. EPC IS FOR T24 & LIGHTING. (complete plan check may required by field inspector)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13563	18041-10000-04120	8222 N TYRONE AVE	91402	6	192B153   924	2212016018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.22042	-118.44412	PC for roofmounted 6kW(AC) PV system in SFD. Installing 24 new modules (7.68kW DC) with optimizers and central inverter. Existing SOLAREDGE SE3000A-US 3kW PV system to be connected in parallel to new system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13564	14041-20000-18597	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			Reviewed by Supervisor	07/25/2014 12:00:00 AM	ADDRESS	34.04538	-118.26335	New service upgrade and distribution equipment for assembly occupancy.application to be void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13565	17041-10007-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	SUPP. PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER DELTA-10, BULLETIN 14.  SCOPE INCLUDES ADDING (2) UPS, (2) 100A PANELBOARDS, AND RELOCATING LOADS/CIRCUITS OF THE LCD RIBBON BOARDS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13566	17041-20000-44042	23115 W SHERMAN PL	91307	12	183B097    55	2021014044	CR-1VL, P-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.20115	-118.63061	ti to an existing medical clinic, first time tenant.  plan check for power and energy.  NON-OSHPD-3BUILDING APPLICATION NUMBER 17016-20000-35070	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13567	16041-10000-23353	2300 W COLORADO BLVD	90041	14	162A221    92	5686001024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.13933	-118.21645	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING EXISTING OUTDOOR LIGHTING AND ADD A NEW INDOOR LIGHTING FIXTURE FOR ELEVATOR SPACE. TOTAL AFFECTED AREA IS 23836 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13568	11041-10000-06403	4900 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.09786	-118.29626	TI TO AN EXISTING OFFICE BUILDING, T-24 OTC PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13569	17041-20001-19112	115 N LA BREA AVE	90036	5	138B181   780	5513002002	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.07405	-118.34423	[[[8/15/17 CHANGES TO APPROVED T24 LIGHTING. PLANCHECK ONLY. DELTA 2 CHANGES ARE CLOUDED . CHANGES TO LIGHITNG LAYOUT]]]ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13570	16041-10000-21491	5300 N LANKERSHIM BLVD #125	91601	2	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.16715	-118.37571	PC FOR ENERGY ONLY FOR A RETAIL, T-MOBILE.  NEW FLOORING, NEW FIXTURES AND RECEPTACLES. TOTAL SQ. FT. 1740.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13571	12041-10000-25076	523 W 6TH ST #1216&-1230	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	TI in an existing office. EPC is for T24 & emergency lights. (12th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13572	16041-10003-15463	3650 W MARTIN LUTHER KING, JR BLVD SUITE 187	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM			PC Approved	09/22/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	"Plan check only. Changes to approved set of plans. Changing pendant lighting labled ""B"" on fixture schedule to non dimmable ornamental lighting only. Note changes marked under delta 6. ***********Changes to approved set, revise the layout and qty of the light fixtures due to the architectural revision in the storage, restroom, and breakroom. All changes noted under Delta-3.* This is Plan check only, permit was issued under the master plan.08/08/16: Changes to an approved set. All changes are clouded under delta A, D, & E. Changes include replacing/relocating lighting fixtures.Note: Original application is under PCIS#16041-10000-15463(((((PC FOR ENERGY ONLY. T.I FOR TIME WARNER CABLE. TRANSFER FROM RETAIL TO TIME WARNER CABLE. TOTAL AREA 3965 SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13573	13041-10002-08175	1045 S WESTWOOD BLVD	90024	5	132B149    54	4363018014	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/16/2013 12:00:00 AM	ADDRESS	34.06161	-118.44559	(((CHANGES MADE TO PREVIOUSLY APPROVED PLANS (13041-10000-08175). EXIT SIGNS CHANGED TO BUGEYES/EXIT SIGN COMBO AND SHOWING SOME MISSING EXISTING LIGHTING)))T24 FOR CHANGE OF USE FROM RETAIL TO BEAUTY SALON. 1961 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13574	16041-10000-41364	5201 N VAN NUYS BLVD	91401	4	172-5A151 218	2249006020	(T)(Q)C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1288.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.16507	-118.44891	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING TO MORE ENERGY EFFICIENT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13575	19041-20000-06488	341 S WESTGATE AVE	90049	11	132B141  1049	4404036008	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.0566	-118.47167	Plan check for a PV1 roof-mounted PV system. System size is 21.24 kWdc/18.9 kWac and consists of (59) AC PV modules and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13576	14041-20001-07003	6310 N BERTRAND AVE	91335	5	177B129  1103	2123022058	R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	PIN	34.18431295	-118.52411166	permit already issued under original application. $0 permit fee under this application due to senate bill 1222 from 2012CHANGE IN DESIGN. NOW CENTRAL TRANSFORMERLESS INVERTER. USING STANDARDPLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13577	16041-10000-01786	1541 W WILSHIRE BLVD 3RD FLOOR	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.05529	-118.26949	T-24, TI ON THE 3ERD FLOOR OF A LOW RISE OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES ON THE BATHROOMS, ELEVATOR LOBBY AND STORAGE ROOM. TOTAL SQ. FT. 576	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13578	15041-10000-01529	642 N LACHMAN LANE	90272	11	129B121   645	4419014037	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.04811	-118.5464	Plan check for a PV1 roof-mounted PV system. System consists of (29) modules and (1) inverter. System size is 6 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13579	14041-10000-24363	4640 N LANKERSHIM BLVD #699	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.15499	-118.36841	Plan check for energy only. T24. No change in occupancy. Tenant improvement of offices. High rise. 4577 sq. ft. Emergency lighting. Suite #699, 6th floor. Fire alarm under seperate permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13580	11041-10000-18036	3 S CHESTER PL BLDG 3	90007	1	123A203   124	5124029016	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	34.03141	-118.27736	TI IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13581	13041-10000-20976	3901 W 6TH ST 1ST FLR	90020	10	135B193   861	5503019010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.06364	-118.30808	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHITING. TENANT IMPORVEMENT.APPLICATION WILL BE ASSOCIATED FOR BOTH PLAN CHECK AND PERMITING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13582	16041-20000-01488	515 S FLOWER ST 16th Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI to (E) commercial office space in commercial high-rise building.  Plan check for energy only: 21,177 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13583	14041-20000-02182	12481 W VIEWCREST ROAD	91604	2	162B165   634	2376005021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.13942	-118.40181	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13584	18041-10001-24210	1728 W 84TH ST	90047	8	097-5A193  56	6034024010	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	33.9626	-118.30786	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13585	17041-20000-17621	1217 S OCEAN FRONT WALK	90291	11	108A143   383	4226005004	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	07/27/2021 12:00:00 AM	ADDRESS	33.98864	-118.47504	Electrical improvements for a 36 unit apartment-hotel building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13586	12041-10000-24616	5811 S SAN PEDRO ST	90011	9	108B205  1113	5101021001	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	33.98946	-118.2703	SMALL AREA IN AN EXISTING BUILDING REMODEL TO OFFICES FOR LAWENFORCEMENTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13587	15041-10000-34860	7843 N LANKERSHIM BLVD APT-BLDG	91605	6	189B169   517	2310025034	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Apartment			10/22/2015 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.21329	-118.38805	Full plan check for a 49 stuido units and (1) 2-bedroom unit. the site plan includes a residential building and a  2-story commercial building sharing a common underground parking. Scope includes a 5000-Amp service 120/208V 3-phase 4-wire. with 6-typical unit. total area for T-24 is 55032-SQ feet.BUILDING PERMIT #15010-10000-03727COMMERCIAL APPLICTION # : 15041-10000-35250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13588	18041-10001-40738	17101 W VOSE ST	91406	6	183B133   413	2227023020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.19859	-118.50576	EXPEDITE PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13589	19041-10000-48231	11752 W TENNESSEE AVE	90064	11	123B149   701	4260029014	R1-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.03144	-118.4478	0$ final fees per AB1414(E-PLAN)CHANGES TO AN APPROVED SET. RELOCATION OF EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13590	14041-20000-02337	4640 N LANKERSHIM BLVD GRD FLR-LOBBY	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.15499	-118.36841	T24 FOR EXISTING OFFICE BUILDING. RECONNECTING TO EXISTING CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13591	18041-20000-07773	20658 W CHESTNUT CIR (#340)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.2936	-118.5848	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13592	12041-10002-01358	10311 S WESTERN AVE 1-63	90047	8	091-5A193 277	6058007004	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Apartment			03/14/2012 12:00:00 AM			Corrections Issued	04/01/2012 12:00:00 AM	ADDRESS	33.94282	-118.30934	Supplemental plan check to seperate roof mounted photovoltaic system from electrical plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13593	18041-20000-42276	7348 N CLEON AVE	91352	2	186B173   835	2410016004	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.20434	-118.368	Plan check for PV roof mounted system, system size: 8.25KW DC,  7.43KW AC with 25 PV Modules and 25 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13594	17041-10000-22118	5937 N VINELAND AVE	91601	2	177B173  1301	2337020005	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.17872	-118.37047	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13595	11041-20000-00696	5645 N TOPANGA CANYON BLVD	91367	3	174B101   191	2146008022	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Apartment			01/12/2011 12:00:00 AM	01/12/2011 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.17326	-118.60606	replace fire alarm panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13596	19041-20000-20044	16913 W BASSETT ST	91406	6	183B133   774	2230007018	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.19572	-118.50184	PV1.  Install 10.8 kW roof mounted grid tied PV system with 13.5 kWh energy storage system.  (30) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13597	12041-20000-29263	8960 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM			PC Approved	12/05/2012 12:00:00 AM	ADDRESS	34.23323	-118.55337	revise energy calc's for manager office and cashier	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13598	16041-10000-37872	333 S GRAND AVE 36TH	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR T24 ONLY. REPLACING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. 36TH FLOOR OF EXISTING HIGH RISE BUILDING INCLUDING CORRIDOR AND RESTROOMS. TOTAL AREA 3297 SQ FT. B# 16016-10000-18037.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13599	14041-10000-22090	4712 N TEESDALE AVE	91604	2	168B161   517	2362025023	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.15622	-118.40816	PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL. STANDARD PLAN.(24) MODULES(1) INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13600	19041-10000-17915	19700 S VERMONT AVE STE 100	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	33.85221	-118.2903	PC for T24 only for a TI. Scope of work is installing new lighting and power.  Affected area is 5100 sqft.((TENANT IMPROVEMENT@ EXISTING OFFICE TO INCLUDE NON LOAD BEARING PARTITIONS, MILLWORK, FINISHES, CEILING))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13601	14041-20000-03462	20661 W CAMPANIA LANE	91326	12	213B109   546	2701070053	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Expired	03/02/2016 12:00:00 AM	ADDRESS	34.2805	-118.58362	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13602	15041-10000-04744	701 E NEW DOCK ST BRT214-220	90731	15	024B209   298	7440021914	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	33.75567	-118.25325	PC FOR POWER. PORT OF LOS ANGELES.(2)NEW 6.6 KVA SHORE TO SHIP POWR AND (1) NEW 4160 V CRANE SWG, 1500 A NEW CRANE BUS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13603	15041-10000-19315	7766 N SAN FERNANDO ROAD	91352	2	189B177   528	2405001017	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.21247	-118.35826	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FIXTURES. TOTAL AREA 14124 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13604	17041-10002-03354	13213 W ROSE AVE	90066	11	114B149   484	4244004024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM			PC Approved	11/03/2017 12:00:00 AM	ADDRESS	34.00899	-118.45386	PC FOR REVISION TO APPROVED SET TO REFLECT FIELD CHANGES. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER ORIGINAL. SCOPE INCLUDES RELOCATION OF DC DISCONNECT AND ROUTING OF (ON ROOF) CONDUIT.PC FOR A ROOF-MOUNED PV SYSTEM WITH BATTERY STORAGE.  INVERTER SIZE 7.6KW AC USING TESLA POWER WALL. BACKFEED UTILITY WITH BACK UP LOAD CENTER INSTALLED AS WELL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13605	19041-20000-08748	6601 S CENTER DR WEST 5th flr	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	33.97997	-118.39375	ti to an existing commercial building (high rise).  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13606	13041-10000-07392	6235 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.18398	-118.60617	CHANGE OF USE FROM A FURNITURE STORE TO RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13607	13041-10000-31563	10414 N WHITEGATE AVE	91040	7	204B193   301	2559010029	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.25822	-118.30476	PV1, Install 3.75 kW DC roof-mounted solar array for 1 story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13608	18041-10000-01681	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	07/13/2020 12:00:00 AM	ADDRESS	34.06047	-118.29555	FIRE WARNING SYSTEM FOR A 120 UNITS APARTMENT BUILDING; FA SYSTEM CONSISTS OF FA PANEL, 4 EA POWER SUPPLIES AND 134 LOW FREQUENCY SPEAKRS AND OTHER FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13609	13041-10000-07220	200 WORLD WAY TERMINAL 2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			Corrections Issued	05/09/2013 12:00:00 AM	ADDRESS	33.94558	-118.4039	PLAN CHECK FOR POWER AND ENERGY IN TERMINAL 2. REMODELING 3 EXISTING SPACES AND COVERTING THEM TO IT ROOMS PLUS 1 NEW IT ROOM AND 1 MPOE ROOM. THE NAME OF THE SPACES: IT ROOM 2105, 2106, 2107, 2108 AND MPOE 1060. SQRFT 1366.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13610	13041-10000-21986	6261 N WILLOW CREST AVE	91606	2	177B177    93	2414017024	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.18482	-118.3628	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 3.43KW DC AND 3.024 KW AC. USING MICROINVERTER STANDARD PLAN. [ INVERTER: ENPHASE # M215-60-2LL-S22 |||| MODULES: REC # REC 250 PE]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13611	11041-10000-15990	8707 N CORBIN AVE	91324	12	195B117   211	2782022019	C2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Expired	08/26/2013 12:00:00 AM	ADDRESS	34.22852	-118.56247	T.I.  Existing 7-eleven.  Remodeling the light fixtures in the retail area only.    Replacing the light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13612	12041-20000-25991	751 N FAIRFAX AVE Ground	90046	5	141B177   490	5527012010	[Q]C2-2D	Central	Hollywood	Mid City West		1920.00, 1944.00	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.08526	-118.36177	Plan check for fire alarm. 1 panel (power supply) and 8 devices. Ground floor. Fishbowl	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13613	11041-10001-24333	2970 W OLYMPIC BLVD	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	05/22/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	REVISIONS TO APPROVED SET OF PLANS- LIGHTING SYSTEM WAS CHANGED AND AREA CATEGORY METHOD USED TO DETERMINE THE ALLOWED WATTAGE FOR THE LIGHTING SYSTEMNew panels and circuits for an existing commercial space.  Applicant requests a Full-Plan-Check for POWER and ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13614	19041-10000-07157	995 N MISSION ROAD	90033	14	133-5A221  94	5410001020	[Q]M2-1-RIO	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.059	-118.21676	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13615	10041-10000-11366	8500 W BEVERLY BLVD #769	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	INTERIOR T.I. TO AN (E) RETAIL STORE ON 7TH LEVEL OF MALL IN UNIT #769 ; plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13616	19041-20000-16579	1665 N SYCAMORE AVE	90028	13	147B181   272	5548007003	R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			05/03/2019 12:00:00 AM			No Progress	08/21/2019 12:00:00 AM	ADDRESS	34.10079	-118.34345	****DO NOT ISSUE - TENANT HABITABILITY PLAN WILL NEED TO BE SUMITTED TO HOUSING DEPARTMENT AS PER CLEARANCE SHEET - REFER APPLICANT TO PLAN CHECKER****SERVICE UPGRADE TO 1200A OF A EXISTING 55 UNIT APARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW 1200A SERVICE, 1200A PANEL, (3) 400A PANELS, 200A HOUSE PANEL, AND (55) 100A PANELS. ALL BRANCH CIRCUIT/UNIT LOADS TO BE RECONNECTED UNDER SEPERATE PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13617	15041-10001-16741	7331 S RINDGE AVE	90293	11	093B149    24	4116028007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM			Reviewed by Supervisor	06/08/2015 12:00:00 AM	ADDRESS	33.95426	-118.44609	EXPEDITED FEE PV1(((PV 1 ROOF MOUNTED SYSTE. 36 MODULES AND 1 INVERTER. TOTAL SIZE. 9.36. (36) KYOCERA #KU2606XPA (1) FRONIUS # IG PLUS A 7.5)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13618	16041-10000-18915	2009 E 25TH ST	90058	14	117A215    59	5167006029	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.0149	-118.23648	T-24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 7971 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13619	14041-20000-02334	16430 W TUPPER ST	91343	12	198B137   571	2676025006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.23922	-118.49054	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC. USING SOLAR OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13620	17041-30001-36664	601 S FIGUEROA ST #2050	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	01-09-2018 Changes to an approved set of plans. Changes include conference room additional but lighting fixture to remain. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13621	15041-10000-03606	916 S MAIN ST	90291	11	109-5A143 472	4286013031	C2-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			Verifications in Progress	03/18/2015 12:00:00 AM	ADDRESS	33.99203	-118.47369	Pc for power and energy. Adding more power to exisiting eletrical system. new service  1200amp, new transformer and new distribution board. commercial building(retail and retail and resturant) not high rise. 6 tenant.Total area 8210 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13622	18041-20000-19416	11526 N MAGEE AVE	91331	7	213B161   589	2533021010	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.27965	-118.41626	Plan check for PV roof mounted system, system size: 5.0kWac with 20 modules and 1 inverter(5.0kW) connected to MSP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13623	16041-20000-22887	23927 W ARCHWOOD ST	91307	12	180B089   209	2034009022	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Expired	08/06/2018 12:00:00 AM	ADDRESS	34.19202	-118.64773	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13624	16041-10000-44408	750 S GRAND AVE #30	90017	14	129A209   250	5144012058	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.04628	-118.25721	PLAN CHECK FOR POWER AND ENERGY , 1ST TIME TENANT (RESTAURANT). SERVICE IS EXISTING UNDER CORE AND SHELL. B# 16016-10000-24865	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13625	17041-10000-35356	9668 N QUARTZ AVE	91311	12	201B117   501	2761021023	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.24557	-118.56421	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(12)MODULES-CANADIAN SOLAR CS6K-275M(12)OPTIMIZERS-P320(1)INVERTER-SOLAREDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13626	14041-20002-09458	5017 N LAUREL CANYON BLVD	91607	2	171B165  1025	2356004017	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.16172	-118.39681	[[[2/7/17 CHANGES TO APPROVED SET. INSTALLATION OF PHASE CONVERTER TO FEED 3 PHASE ELEVATOR]]]]600 AMP SERVICE. NEW CONSTRUCTION, 3-STORY APARTMENT WITH 4 UNITS.PLAN CHECK FOR POWER AND ENERGY.NEW 4 UNIT APTmodification for plan check extension filed 10-13- 15	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13627	10041-10000-12162	10 S BEVERLY RIDGE TER	90210	5	153B161   102	4387016041	RE40-1-H	South Valley, West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.11545	-118.40623	NEW 29,000 SQR FT SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13628	13041-10001-25976	1902 E MARENGO ST	90033	14	132A223    33	5201016003	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.05756	-118.21009	Plan check for fire sprinkler monitoring system per inspector request. FIRE SPRINKLER MONITORING SYSTEM: (35) FIRE ALARM DEVICES, (7) CONTROL DEVICES, (1) COMMUNICATION PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13629	12041-10000-13086	8350 N HILLCROFT DR	91304	12	193-5A089 111	2017024029	RE15-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	08/13/2012 12:00:00 AM	ADDRESS	34.22449	-118.65129	Plan check for new 10.71KW roof mounted Photovoltaic System. Permit for service panel upgrade and PV system installation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13630	16041-20000-28567	8300 N TAMPA AVE #A	91324	12	192B117   733	2784019004	C2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.2208	-118.55334	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG.  TOTAL SQUARE FOOTAGE 1810 TENANT A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13631	16041-20001-45024	4745 N ALONZO AVE	91316	5	168B129   456	2182016004	RA-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			PC Approved	01/13/2017 12:00:00 AM	ADDRESS	34.15681	-118.52153	Expedited plan check fee per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13632	12041-20001-01947	601 S FIGUEROA ST #2700	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			PC Approved	04/19/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	energy plan check suite 2700. Changes to lighting. Supplemental to 12041-20000-01947. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13633	14041-10000-13051	3608-3610 W EDENHURST AVE	90039	13	154-5A207 196	5435026023	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM			PC Approved	05/15/2014 12:00:00 AM	ADDRESS	34.11811	-118.26136	T24 only. Total area 1258 sq ft. Changing from timer to sensor accupancy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13634	18041-10000-32301	716 N ALVARADO ST	90026	13	138A207    31	5404008031	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.20	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.07423	-118.26529	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13635	13041-20000-15913	12629 W RIVERSIDE DR 1-217	91607	4	168B161   362	2357028025	(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Apartment			06/17/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.1578	-118.40799	Fire alarm for a new apartment complex.  217 unit, 4-story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13636	15041-10000-43505	10150 N CANOGA AVE	91311	12	204B105   482	2747009074	(Q)CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.25502	-118.59711	PC for energ only. Romove HID light fixtures and replace with new LED fixtures. Total sq ft = 2432	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13637	16041-20001-34024	18038 W VALLEY VISTA BLVD	91316	5	168B125   299	2181028021	R1-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.15805	-118.52622	expedite per applicantpv1install roof mounted pv system sized 12.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13638	12041-10000-03695	9640 N OWENSMOUTH AVE	91311	12	201B105   205	2746015006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM			PC Approved	03/09/2012 12:00:00 AM	ADDRESS	34.24548	-118.60221	Replacing esisting damaged / stolen 2500A switchboard, distribution boards, and new feeders to existing building. No new load added. All equipment are replaced Like to Like.  Permit was issued under 12041-10001-03695.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13639	14041-10001-12853	3351 S GAFFEY ST	90731	15	006B197     4	7469018904	OS-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	33.71374	-118.29306	PC FOR DELTA 3 ON ORIGINAL PLANS CHAGES INCLUDE ADJUSTMENTS TO ON SITE INSTALLTION OF LIGHTING.ALL TITLE 24 DOCUMENTS HAVE BEEN REVISED. NO POWER PLAN CHECK REQUIERD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13640	13041-10002-15851	9947 N MARCUS AVE	91042	7	202-5A201 337	2568015031	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.20	Electrical	Electrical	Apartment			04/17/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.24914	-118.282	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA B ONLY CHANGING TO SERIES RATED OF ELECTRICAL EQUIPMENTS.<<<New 9 unit two-story apartment building.  Power and energy plan check.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13641	17041-10000-11704	4324 S LIMA ST	90011	9	114A213   399	5116019014	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Issued	04/17/2017 12:00:00 AM	ADDRESS	34.00495	-118.24613	Plan check for PV1 roof mountd solar system for a single family home. New Inverter rated at 3.8 KW, 17 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13642	15041-20002-42250	3764 S DUBLIN AVE	90008	10	117B189   546	5034013049	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	PIN	34.01823208	-118.32207663	02-03-2016 Change to approved set of plans. Changes include module layout on the roof. {{{{{{PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.12KW}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13643	19041-20001-12664	10252 N TUNNEY AVE	91324	12	204B117   203	2726016001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.25689	-118.55782	CHANGES TO APPROVED SET DELTA 2 ONLY. CHANGES APPLY TO LOAD CALCS. <<<Installation of 13.5 kWh energy storage system and associated distribution/critical load panel.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13644	17041-20002-24961	3576 N SEPULVEDA BLVD	91403	5	162B141   488	2280021023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.13646	-118.48517	Revisions to approved set of plans.  Change of wiring detail from roof-mounted conduit to Romex routed through attic space.  Approval for clouded portion of sheet 3 of 4 only.  $0 plan check fee due to State Senate Bill SB 1222. (((PV1. PC FOR PV SYSTEM USING AC MODULES. TOTAL OF 32 MODULES. TOTAL SYSTEM SIZE IS 11.04 KWac.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13645	10041-10000-16872	1317 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05087	-118.22477	Solar voltaic system installed on the roof of the building.  Consists of  6 modules,  6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13646	14041-20000-09165	5601 W WILSHIRE BLVD	90036	4	135B181   891	5508013034	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.06252	-118.35061	TI to existing grocery store, installation of coffee vendor kiosk.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13647	16041-20000-31804	10403 N SANDLEWOOD LANE	91326	12	204B121   667	2728020046	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.25917	-118.54347	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.5KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13648	16041-20000-19388	7036 N ST CLAIR AVE	91605	2	183B165   167	2321005019	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.19872	-118.39974	PV1.  Install 7.28 kW roof-mounted PV system.  Central inverter standard plan.  (28) modules with (1) 6 kW rated transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13649	13041-10000-08910	11980 W SAN VICENTE BLVD SUITE 710B	90049	11	129B141   232	4265007052	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	34.05208	-118.47215	PC FOR ENERGY. PSYCH OFFICE OF MEDICAL PLAZA. 973 sf. emergency and 23 cfl lights. emergency supplied by GENERATOR for plaza.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13650	13041-20001-34285	8700 W WENTWORTH ST	91040	7	207B189   154	2547002002	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.26706	-118.32394	RESTAMP FOR NEW LOCATION OF MAIN SERVICE PANEL. RECHECK FOR LOCATION ONLY. NO CHANGE IN ELECTRICAL LAYOUT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13651	11041-20000-07248	861 N LA CIENEGA BLVD	90069	5	144B173   404	4337002048	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM			Corrections Issued	04/17/2011 12:00:00 AM	ADDRESS	34.08698	-118.37659	Resubmit plans.  Original plans approved under 10041-20000-17448.  *****Plan check power and energy for restaurant TI. Type A occupancy. Existing service and panels.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13652	12041-20000-23848	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.06338	-118.20434	Title 24 energy only for an office remodel. 1675 quare feet. (Suite 220)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13653	10041-20000-24886	1312 E 7TH ST Bldg A1-Unit #28	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	ADDRESS	34.03615	-118.24064	"Plan check T24 Energy for tenant improvement to interior of storage room (Unit #28) in building A1. Title 24 only. Existing branch circuits.""COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13654	15041-10001-43405	3818 W 58TH PL	90043	8	105B181    16	4004009005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	33.98784	-118.3406	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(13)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB## PVI-3.0-OUTD-S-US-Z-ANOTE: PULLING AN ADDITIONAL 4 MODULES FOR PERMIT. CLEARANCE AND PERMIT FOR MOST OF ELECTRICAL PERMIT IS PULLED UNDER PCIS#15041-90000-43405(((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13655	16041-20001-08799	14945 W WYANDOTTE ST	91405	6	186B145   699	2221014016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM			PC Approved	04/25/2016 12:00:00 AM	ADDRESS	34.20311	-118.45901	Revisions to approved plans.  Change of service size from 200A to 100A to reflect as-builts.    (((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.5 KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13656	13041-10000-14955	18140 W HERBOLD ST	91325	12	201B125   396	2764017067	RE9-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.24491	-118.52891	PV1.  Install 2.21 kW DC roof-mounted solar array, interconnect with main panel.  Tie with existing solar installation at solar load center.  {9 modules: Trina Solar TSM-245PC05/PA05.18} {Transformerless inverter: SolarEdge SE3000A-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13657	13041-10001-32321	4912 N RHODES AVE	91607	2	168B165   194	2356026014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.15977	-118.40298	Expedited RSES plan check per applicant request.(((PV1, Install 5.5 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 22 modules TRINA SOLAR TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13658	15041-10000-29114	437 S BROADWAY FLR2,3,4	90013	14	129A211    47	5149026008	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Issued	11/12/2015 12:00:00 AM	ADDRESS	34.04875	-118.25034	SERVICE UPGRADE TO AN EXISTING COMMERCIAL BUILDING.  NEW 3000AMP SERVICE. PHASE II TO INCLUDE FLOOR 2,3,4. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13659	10041-10000-08553	8723 W ALDEN DR 2ND FL	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.0754	-118.38272	TENANT IMPROVEMENT REMODEL OF EXISTING OFFICES, EXAM ROOMS, LABORATORIES, AMBULATORY CARE ; PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13660	12041-20000-20704	10122-10124 W EMPYREAN WAY	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.05336	-118.40936	Install new meter banks to existing underground pull sections to supply existing feeders and existing panels for condominium units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13661	14041-20000-21732	4503 S GLENCOE AVE 100-150	90292	11	105B153    96	4212007009	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	33.98462	-118.43524	T.I to existing two story commercial building.  Removal and additional subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13662	10041-20000-25240	9601 N CANOGA AVE #200	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Finaled	12/30/2010 12:00:00 AM	ADDRESS	34.24501	-118.59876	PLAN CHECK T24 ENERGY FOR TI ROOM #200 GENERAL INDUSTRIAL WORK - PRECISION SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13663	13041-20000-30435	8401 N VAN NUYS BLVD Space#K111	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.22308	-118.44896	T24 FOR NEW KIOSK. TOTAL NEW CONNECTED LOAD IS LESS THAN 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13664	16041-20000-09634	6126 E CRESTWOOD WAY	90042	14	159A231   119	5481002023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	04/02/2016 12:00:00 AM	ADDRESS	34.131	-118.1877	PV1.  Install 2.0 kW DC roof-mounted PV system.  Microinverter standard plan.  (8) modules with Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13665	19041-20000-04696	7230 N MEDICAL CENTER DR 3rd Floor	91307	12	183B097    18	2021014042	QCR-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.20143	-118.62922	Plan check for power and energy. Project site is the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,050 sq. ft.Note: Building application has been generated under 18016-20000-37971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13666	16041-10000-14638	8500 W BEVERLY BLVD LVL. 6	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			Verifications in Progress	04/29/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT. EXISTING TENANT SPACE TO BE CONVERTED INTO WOMEN'S RESTROOMS ON LEVEL SIX.  INSTALL (N) LIGHT FIXTURES. PC FOR T-24 ONLY. TOTAL AREA ~ 585 SQ. FT. (restrooms + corridor area)B# 16016-10000-07008(Pre-screened w/A.F.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13667	19041-10000-06529	4650 W SUNSET BLVD	90027	13	147B197   720	5542016030	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.09787	-118.29063	ADDING NEW DEVICES TO EXISTING FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13668	11041-20001-18592	510-516 S LANDFAIR AVE	90024	5	135B149   156	4363005046	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.04	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	34.0683	-118.4506	Modification to approved plans.  See new feeders and new equipment.  Note that not all modifications have been clouded on the plan.  See approved set of plans for reference.  Plan Check Only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13669	15041-10001-34316	5630 N FIGUEROA ST	90042	1	151-5A229 295	5468032017	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.10933	-118.19295	Changed to approved set of plans. Redesigned of lighting plan only. Note changes under delta 1. ((PC FOR ENERGY. T.I. FOR  A RESTURANT. TOTAL 1395 SQ FT.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13670	16041-10000-29009	3050 N NORTH COOLIDGE AVE	90039	13	150B213   771	5442022033	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.1051	-118.24371	restaurant ti, new lighting. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13671	17041-20000-29414	3819 E SAN RAFAEL AVE	90065	1	148-5A221 103	5464014002	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	10/28/2017 12:00:00 AM	ADDRESS	34.10117	-118.2184	PV1.  Install roof mounted PV system sized 7.6kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13672	17041-10000-01662	3201 S HOOVER ST Bldg 8 C3-RR	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	Plan check for power and energy 1st time tenant. Restroom and break room Builidng 8 C3Total area: 702 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13673	19041-10001-23251	1530 S BUTLER AVE	90025	11	129B149   526	4261003900	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM			PC Approved	10/30/2019 12:00:00 AM	ADDRESS	34.04596	-118.45213	change to an approved set, relocating of 4 EV chargers and updating voltage drop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13674	13041-20000-23044	10100 W SANTA MONICA BLVD SUITE 1000	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/23/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.06191	-118.41691	RENOVATION OF OFFICES SPACES. NEW LIGHTING. PC FOR T24 ENERGY ONLY. NEW CONNECTED LOAD LESS THAN 400A. WORK DONE IN SUITE 1000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13675	18041-10000-40718	17535 W DONMETZ ST	91344	12	210B129   112	2711007008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.27464	-118.51661	Permit fee is $0.00 due to AS1414PC FOR SFD PV SYSTEM (TESLA ROOF TILE) SCOPE INCLUDES ABOUT 4000 SQ.FT OF TILES (988 MODULES ), 3 INVERTERS NEW SUBPANELS AND LOAD CENTER. TOTAL SYSTEM SIZE 19KWAC / 23.465 KWDC ESS  40.5KWH ENERGY STORAGE SYSTEM UNDER SEPARATE PERMIT (SUPP)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13676	14041-10001-21173	5249 N LOLETA AVE	90041	14	163-5A227 155	5669011015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			Reviewed by Supervisor	08/15/2014 12:00:00 AM	ADDRESS	34.14273	-118.19827	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 4.08 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13677	11041-10002-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	33.94386	-118.4047	REVISION MADE TO PREVIOUSLY APPROVED SETS OF PLANS. ADDED TWO PANEL BOARD , RVISED ELEVATOR FEEDERS, REVISED MOTOR H.P. AND ADDED 15 NEW BRACH CKTS. FOR CENTRAL PLANT LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13678	12041-10000-13111	13016 W RUNWAY ROAD	90094	11	102B157   224	4211021263	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	ADDRESS	33.97356	-118.42325	Replace existing light poles and landscape lighting with new LED fixtures.Plan check for energy only. 12136 hardscape area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13679	19041-10000-13420	141 N UNION AVE	90026	13	135A207    44	5159008025	RD1.5-1	Central	Westlake	Echo Park		2084.02	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Issued	04/12/2019 12:00:00 AM	ADDRESS	34.06576	-118.26534	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13680	18041-20000-33426	20700 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.29241	-118.58429	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13681	18041-10000-01910	23781 W BURTON ST	91304	12	192B089    90	2020010020	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.21871	-118.64593	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 23 AC MODULES  AND NEW PANEL. TOTAL SYSTEM SIZE 7.36KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13682	19041-20000-52859	14639 W VANOWEN ST	91405	6	183B149   751	2219022019	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	06/16/2020 12:00:00 AM		Permit Finaled	08/11/2021 12:00:00 AM	ADDRESS	34.19406	-118.45229	FULL PC FOR A NEW 600A SERVICE (20/240 1P,3W) THATS FEEDS A 600AMP DISTRIBUTION BOARD THAT SUBFEEDS NINE 100AMP SUBPANELS. THE NEW SERVICE ALSO FEEDS A 100A METER BOARD SECTION FOR ALL ASSOCIATED HOUSE LOADS. TOTAL AFFECTED AREA IS 5371SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13683	19041-10000-08686	2723 W TEMPLE ST	90026	13	138A203   145	5156025032	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village		1958.02	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.07332	-118.27633	Energy plan check for removing HID fixtures  and replace with new LED fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13684	17041-20002-42226	10410 N BECKFORD AVE	91326	12	204B121    44	2728010002	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.25935	-118.55103	1/24/2018changes to an approved set of plans.  changes include point of connection from line side tap to load side termination.  this is plan check only.  (((pv1install roof mounted pv system sized 5kw interonnected with msp.  line side tap.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13685	17041-10000-41037	5550 W WILSHIRE BLVD 101A	90036	4	132B181  1299	5089005***	[Q]C2-1-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	04/19/2018 12:00:00 AM		Issued	04/19/2018 12:00:00 AM	ADDRESS	34.06206	-118.34979	PC FOR INTERIOR T.I. FOR FIRST TIME TENANT IN MIXED USED  (FED-EX STORE) FOR POWER AND ENERGY.TOTAL AFFECTED AREA 5174 SQ.FTSCOPE INCLUDES NEW PANELS, CIRCUITS, LIGHTS AND EQUIPMENT. B# 17016-10000-33636	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13686	14041-20000-07473	11022 W CAMARILLO ST	91602	4	168B173   488	2353026004	R3-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	Apartment			03/20/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.15745	-118.37141	New 15 unit apt. over on grade parking.  New 800A service.  Plan check for power and energy.  Note: Variance to separate F.A. plan is filed.  Title 24 will be submitted before the plans getting assign.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13687	11041-10000-26935	728 W VERNON AVE	90037	9	112-5A201  94	5018032032	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.00352	-118.28673	New 7-11 retail store in exist. tenant space,  plan check power & energy.NINSTALL INTERIOR FINISHES INCLUDING PORCELAIN FLOOR TILE,  1  X 4  CEILING  GRID, FRP, REMOVE EXTERIOR CAN LIGHTS, INSTALL NEW LED STRIP LIGHTS; LANDLORD IS INSTALLING DEMISING WALL, 2 RESTROOMS, UNDERSLAB PLUMBING, <SEE COMMENTS>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13688	12041-20000-03113	300 S GRAND AVE 36th Floor	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	03/12/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to high rise building on the (partial) 36th floor.  Install general/emergency lighting in rooms 3614, 3615, 3636, 3637, 3662, and restrooms as shown on plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13689	15041-20000-16306	936 S OLIVE ST UNIT 352	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #13 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13690	11041-20000-15620	4129 N KRAFT AVE	91604	2	162B169   138	2368021005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	11/18/2011 12:00:00 AM	ADDRESS	34.14344	-118.38019	Plan check new roof mounted Enphase Microinverter Photovoltaic System for single family dwelling. Modification for Enphase M215 to be installed prior to testing agency approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13691	17041-10000-17117	3549 1/4 E SISKIYOU ST	90023	14	121-5A227 300	5188016023	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Expired	03/06/2024 12:00:00 AM	ADDRESS	34.0251	-118.19765	Installation of new roof mounted solar PV array on existing duplex.  Central inverter system.  Total system size = 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13692	13041-10000-17634	2828 W JAMES M WOOD BLVD	90006	1	132B197   821	5077029018	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	PIN	34.05562955	-118.28998903	adding luminaires to exterior of apartment buildingplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13693	16041-20000-37290	13340 W VANOWEN ST	91405	2	180B157    51	2329020022	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	34.1938	-118.42413	Plan check for Title 24 only. Project site is a new 3-story apartment building with street level parking. Project scope is commom area lighting. Total lighting area = 2,057 sq. ft.Note: Building application has been generated under 16010-20000-04886	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13694	13041-20000-26642	9042 N SEPULVEDA BLVD	91343	7	195B145   655	2654004053	R3-1, [Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	ADDRESS	34.23467	-118.46632	T24 FOR EXISTING HAIR SALON.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13695	18041-10000-35096	9000 N GLENOAKS BLVD	91352	6	195B173   120	2408005034	(Q)M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.23263	-118.36908	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13696	12041-10000-30793	458 S MAIN ST UNIT 111	90013	14	129A211   157	5148009015	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM			PC Approved	01/29/2013 12:00:00 AM	ADDRESS	34.04683	-118.24814	POWER FOR ICE CREAM STORE, FIRST TIME TENENT. FULL PLAN CHECK FOR POWER AND ENERGY. PART OF HIGH RISE. INSPECTOR TOM Z.  REQUEST PLAN CHECK AND T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13697	14041-10000-28763	4270 S VERMONT AVE	90037	9	114B197  1038	5020034034	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.00585	-118.2913	Full plan check for a new self Serve Car wash & future T.I building. equipment include 600-Amp service, (2) panels and motors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13698	12041-10000-09871	446 N FAIRFAX AVE	90036	5	141B177  1284	5527030023	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.07951	-118.36128	Plan check T24 Energy/Emergency lighting for Urban Garden restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13699	18041-10000-42418	7821 N BURNET AVE	91405	6	189B145   515	2209032016	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.21295	-118.46306	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13700	13041-20000-12990	424 N CRESCENT HEIGHTS BLVD	90048	5	141B177  1393	5514006035	R1-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.07893	-118.36571	New Ungrounded Rooftop PV system for an existing single family residence.  Site is in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13701	15041-20002-04792	14141 W VENTURA BLVD SUITE B	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Issued	06/02/2015 12:00:00 AM	ADDRESS	34.14992	-118.44152	CHANGES TO APPROVED SET OF PLANS. CHANGE TO T24 LIGHTING, CONTROLS AND SINGLE LINE DIAGRAM. RECHECK FOR NEW PANEL HOME RUNS AND RECHECK T24. NEW PANEL ADDED. PERMIT TO BE ISSUED FOR NEW PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13702	19041-20001-08256	6000 N DE SOTO AVE	91367	3	177B109    16	2149004023	(Q)R4-2D	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.17936	-118.58884	NEW ROOFTOP PV SYSTEMS FOR EXISTING APARTMENT BUILDING. SYSTEM IS 135 KW DC/ 121.23 KW AC CEC/ 120 KW ACSCOPE OF WORK INCLUDES (375) ASTROHALO PV MODULES, (187) P730 OPTIMIZERS, (4) SE30KUS INVERTER,  (1) 150KVA TRANSFORMERS,  AND (1) 200A PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13703	17041-10000-18642	5128 N FIGUEROA ST	90042	1	150A227   154	5468005032	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM			Verifications in Progress	09/01/2017 12:00:00 AM	ADDRESS	34.1059	-118.19991	PC for power and energy for new car wash. PC for new 600 A 480/277 V service and new blower and washing equipment. Total area is  11872sqft.Building # 17014-10000-02503.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13704	17041-20000-03721	13720 W VANOWEN ST	91405	2	180B157    55	2238010030	C2-1, R1-1, [Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.19378	-118.43188	Plan check for power only. Project site is a new car wash. Project scope is a new service of 600-amps and new distribution equipment.Note: Building permit has been pulled under 15010-30000-00895	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13705	17041-20000-12357	3000 S ROBERTSON BLVD ste 135	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	ti to an existing commercial office suite 245.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 4232.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13706	13041-20000-25127	22614 W MIRANDA ST PV1	91367	3	174B097   296	2040007012	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.17455	-118.6196	New Roof Mounted PV system on an existing single family dwelling.  System uses Enphase Microinverters.  Submittal per applicant's request.  Plan Check/Permit only for PV System, NOT for Main Service upgrade or de-rating main breaker.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13707	14041-10000-01819	742 W CHANNEL ST	90731	15	021B197   367	7445008034	M1-1VL	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	33.75392	-118.29334	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 1540 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13708	19041-10000-37495	4144 S KENYON AVE	90066	11	108B157    94	4231018005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Expired	09/11/2023 12:00:00 AM	ADDRESS	33.99578	-118.42875	0$ fee due to AB1414. Changes to approved PV1 set. Scope includes new 60A AC disconnect. Master application #: 19041-10000-31462	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13709	16041-10000-26363	6300 W WILSHIRE BLVD STE 950	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.06319	-118.36591	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3271 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13710	13041-20000-20932	8944 N FULLBRIGHT AVE	91311	12	195B113    38	2781001023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	34.23337	-118.57739	T24 ENERGY  AND PERMIT ALREADY UNDER APPLICATION 13041-20000-14164. PER INSPECTOR, FIRST TIME OCCUPANT. FULL PC FOR POWER AND ENERGY REQUIRED. THIS APPLICATION IS FOR CHANGES TO APPROVED T24 ENERGY AND FOR PLAN CHECK FOR POWER. THIS APPLICATION IS PC ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13711	17041-10000-18098	101 S BRIDEWELL ST	90042	14	153A233   288	5492038025	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.03	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.11282	-118.17794	PC for power for upgraded main switchboard from 600A  to 1000 A switchboard. Scope of this permit is clouded under delta 1 (See sheet PV-4).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13712	15041-10000-36124	10539 W LE CONTE AVE	90024	5	135B153   165	4360020019	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Expired	12/08/2017 12:00:00 AM	ADDRESS	34.06731	-118.43454	PV1, ROOF MOUNTED SYSTEM TOTAL SIZE 8KW-AC. (24) MODULES AND (1) 8KW INVERTER. (24) SUNPOWER SPR-327NE-WHT-D(1) SMA-8000-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13713	11041-10000-09645	3616 S TROUSDALE PKWY AHF BLDG-# 209	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.01983	-118.28534	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13714	13041-10000-04296	8445 W MELROSE PL	90069	5	141B173   420	5528001032	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			Corrections Issued	02/20/2013 12:00:00 AM	ADDRESS	34.08375	-118.37476	T24 for existing retail space. Tailored method. Lighting and receptacles only. 3000 sqrft indoor and outdoor lighting. Electrical permit to be pulled at electrical plan check counter ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13715	11041-10000-05098	140 E HURRICANE ST	90292	11	103-5A147 272	4225010900	RW1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM			PC Info Complete	04/12/2011 12:00:00 AM	ADDRESS	33.97589	-118.46122	Install three valve actuators, and one flow meter for waste water pump plant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13716	11041-20000-05368	3415 S SEPULVEDA BLVD 6th Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	06/09/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	"T.I. for a high rise building.  Install general/emergency lighting in elevator lobby and corridor.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13717	15041-30000-42271	4641 N CARITINA DR	91356	3	168B117   474	2178015005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.15457	-118.55667	Addition of new roof mounted solar PV array on existing single family dwelling.  Total system size = 8.2 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13718	18041-20001-40141	340 N MADISON AVE	90004	13	138B197   141	5501002033	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM			PC Approved	10/04/2019 12:00:00 AM	ADDRESS	34.07748	-118.28901	SUPPLEMENTAL, PLAN CHECK ONLY, FOR LARGE REDUCTION TO SCOPE OF WORK. ALL CHANGES ARE UNDER CLOUDED DELTA ONE. CHANGES MADE TO ALMOST EVERY PAGE, MAINLY FLOOR PLAN AND TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13719	14041-20001-24867	7006 S HOOVER ST UNIT 8	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #8.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13720	19041-20000-37439	848 S SIERRA BONITA AVE	90036	4	132B177   446	5089017009	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.0593	-118.35499	Plan  check for PV roof mounted and Energy Storage System, PV system size: 7.59KW DC, 6.99KW AC with 23 PV Modules and 23 microinverters and 1 Tesla Battery 13.5KWh and sub-panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13721	16041-20000-21647	9936 N HANNA AVE	91311	12	201B101    49	2745004018	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	07/16/2016 12:00:00 AM	ADDRESS	34.25106	-118.60734	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13722	14041-10000-10339	4810 S CENTRAL AVE	90011	9	111A209   104	5107019003	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Issued	04/21/2014 12:00:00 AM	ADDRESS	33.99941	-118.2563	INSTALL NEW 600A SERVICE FOR COMMERCIAL WAREHOUSE BUILDING ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13723	18041-20000-09378	9618 N VARIEL AVE	91311	12	201B105   207	2746006019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Issued	03/22/2018 12:00:00 AM	ADDRESS	34.24536	-118.59269	Service upgrade for 1600A 480Y/277V service.  Reconnect existing loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13724	15041-10001-15839	1144 S HOPE ST	90015	14	126A207    51	5139021021	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.04108	-118.26392	ALTERATIONS IN A DANCE STUDIO-NEW CKTS ,LIGHTINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13725	14041-20000-30437	642 E 118TH ST	90059	15	084B205   720	6084004009	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Expired	11/28/2016 12:00:00 AM	ADDRESS	33.92632	-118.26379	PV1Install a roof-mounted solar array on a SFD. Interconnect with 100A MSP.System size: 3.44kW.16 EnPhase M215 microinverters attached to 16  250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13726	14041-20000-02748	1625 W PACIFIC COAST HWY	90744	15	036B201   489	7413023238	[Q]RD2-1XL	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	33.79121	-118.28678	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. NEW LIGHTING. LIGHITNG LOAD HAS LESSEN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13727	15041-10000-43037	1321 E PALMETTO ST	90013	14	126A217    38	5164003012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.04034	-118.23199	Ti to existing offices, pc for energy only. Adding new lighting and receptacles. Total sq ft =1292	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13728	16041-20001-28732	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	6/27/17changes to an approved set of plans.  changes include revised energy calculations and removal of electrical panel.  this is plan check only. TI TO AN EXISTING COMMERCIAL SPACE (KIOSK).  NEW LIGHITNG NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 63.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13729	16041-20000-27223	818 N AVENUE 51	90042	1	153A225    14	5478015005	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.1155	-118.20625	INSTALLATION OF A BATTERY BACKUP STORAGE SYSTEM IN RESIDENTIAL. 2KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13730	18041-20003-23162	1405 S WELLESLEY AVE	90025	11	126B145   822	4267032015	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.03973	-118.46588	10/31/19CHANGES TO APPROVED SET DELTA B ONLY.<<<Plan check for power and energy for change of use from Home of the Age to Hotel mixed use existing building. Total area: 47739 sq ft. B#18016-1000004044>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13731	15041-10001-30381	350 S GRAND AVE	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			PC Approved	07/08/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	CHECKING FOR CHANGES TO APPROVED SET OF PLANS. CHANGES SHOWN IS REMOVAL OF 2 HOUR PROTECTION OF COMMUNICATION AND NOTIFICATION CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13732	11041-10001-02243	2230 W 6TH ST	90057	1	133-5A203 110	5141003900	OS-1XL	Central	Westlake	MacArthur Park	YES	2088.00	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.06036	-118.27704	The scope of work is to install conduit seals in two underground conduits for 6 new circuits pulled from an existing electrical panel to supply interior and exterior lighting, one exterior WP GFCI receptical, and some  hardwired handdryers for a restroom building.  The building is located in a Methane Buffer Zone.  The original plancheck  was for T24 lighting only as the existing electrical service is rated only 400 amperes and the existance of the methane buffer zone was not know.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13733	17041-10000-12186	1325 S HOOVER ST	90006	1	129A201   292	5056008025	R4-1VL	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.04648	-118.28442	PC for energy only, Outdoor Title 24. Remove HID fixutres and replace them with LED. Area:  6,490 SQft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13734	15041-20000-35413	3480 S 2ND AVE	90018	10	120B189  1158	5042003020	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.0232	-118.31876	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.4 KWac.(28)MODULES-SUNPOWER 327W MODULES(2)INVERTER PVI-4.2OUTD-US (240V)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13735	19041-10000-02549	9520 N OWENSMOUTH AVE # 7	91311	12	201B105   246	2746015011	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.24348	-118.60223	PLAN CHECK FOR TITLE 24 ONLY FOR - Fire damage repair of roof framing in unit 7 (less than 10% damage). Upgrade 2-bathrooms for disable access. - TOTAL AFFECTED AREA = 2200 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13736	19041-10001-00183	1053 S ORLANDO AVE	90035	5	132B173   596	5087006012	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.05771	-118.37399	FEE EXPEDITEDPC FOR NEW 10KW AC SFD ROOFTOP SOLAR SYSTEM WITH 14KW ENERGY STORAGE SYSTEM. SCOPE OF WORK INCLUDES (1) 200A LOAD CENTER, (36) 325W DC PV PANELS, (1) 10KW SE10000A INVERTER, AND (2) 7KW TESLA POWERWALL BATTERIES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13737	12041-10000-26682	10801-10807 N SAN FERNANDO ROAD Bldg D	91331	7	207B157   309	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Info Complete	11/26/2012 12:00:00 AM	ADDRESS	34.26635	-118.42259	Methane mitigation submittal - Building 'D' Restoration of building. Interior and Exterior remodel. (Buildings A through D were submitted together application numbers are: (A) 12041-10000-26679, (B) 12041-10000-26680, (C) 12041-10000-26681, (D) 12041-10000-26682)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13738	14041-10000-02368	1307 W 78TH ST	90044	8	099B197   328	6019005014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	33.9695	-118.29847	PV1, ROOF MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 100A MAIN SERVICE PANEL. SYSTEM SIZE IS 3.5 kW DC, WITH (14) TRINA  TSM-250PA15, (1) POWER-ONE INVERTER PVI-3000. SINGLE-STORY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13739	16041-10000-03414	1520 N SAN PABLO ST	90033	14	135A225    64	5202004042	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.0627	-118.20276	(T-24, PC FOR ENERGY ONLY. TI TO AN AN EXISTING COMMERCIAL BUILDING (USC MEDICAL OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES TO OFFICE/CONFERENCE SPACE ON THE 4TH FLOOR. TOTAL AFFECTED AREA IS 739 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13740	18041-10001-28402	1 S LMU DR SUITE 4900	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Issued	10/05/2018 12:00:00 AM	ADDRESS	33.96577	-118.42406	Change to approved set by adding ckts, updating the floor plan and panel schedule. All changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13741	13041-10000-27039	101-119 S LA BREA AVE	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Public Safety Only			09/30/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.07338	-118.34425	there are three buildings (A -2FLRS), (B-3FLRS), C-2FLRS)  each sharing a wall with the other;NEW FIRE WARNING SYSTEM-CORE/SHELL- FOR BUILDINGS A;B;C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13742	13041-10000-02777	13429 W HARTLAND ST	91405	2	183B157   814	2328014006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM	02/04/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.195	-118.42565	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. TOTAL SYSTEM SIZE OF 7.92 KW. USING 33 SOLAR MODULES TRINA SOLAR TSM-240PA05. CENTRAL INVERTER SMA SUNNY BOY 7000-US. PV1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13743	14041-10000-12035	1925 S CENTURY PARK EAST	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	05/08/2014 12:00:00 AM	ADDRESS	34.06066	-118.41426	Tenant improvement to commercial high rise (office building).  Title 24 only.Total area = 2991 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13744	10041-10001-06423	800 E 12TH ST #145,146 &-147	90021	14	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM			PC Approved	04/16/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	INTERIOR REMODELLINGOF RETAIL STORE- ADDING TWO ADJACENT TENANT SPACES TO MAKE ONE TENANT SPACE NEW LIGHTING CIRCUITS ; PLAN CHECKED FOR THE ADDED CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13745	16041-10000-34703	724 N STANLEY AVE	90046	5	141B177   459	5526014018	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.08452	-118.35623	PV, NEW 11.5 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILLY HOUSE. (39) MODULES: SOLARWORLD SW285 MONO BLACK(39) AC INVERTERS: ENPHASE M250-80-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13746	18041-10000-12156	6707 W 88TH ST	90045	11	096B161   808	4122020011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	33.95725	-118.4071	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.2 KW. INSTALLING GATEWAY FOR FUTURE ENERGY STORAGE DEVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13747	12041-10000-18381	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	PLAN CHECK POWER AND ENERGY FOR (1ST, 2ND, 3RD FLS)  T.I. FOR PRIVATE PHARMACY SCHOOL.  5-STORY EXISTING BUILDING NEW ELECTRICAL (CORE&SHELL) POWER PLAN CHECK UNDER #12041-10000-07193.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13748	12041-10000-24005	6820 N SHOSHONE AVE	91406	12	183B129  1019	2229003024	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.19452	-118.5162	7.8 kw roof mounted PV for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13749	11041-10000-05723	5510 W SUNSET BLVD	90028	13	147A193   108	5544029011	C2-1	Central	Hollywood	Hollywood Studio District		1909.01, 1911.10	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Expired	04/16/2013 12:00:00 AM	ADDRESS	34.09788	-118.30974	One story commercial bldg, one panel and 5 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13750	17041-10000-20523	11300 W OLYMPIC BLVD 770	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.03792	-118.44134	PC for T24 only for TI in office building with 3726 sqft. PC for lights and receptacles. Load under 400A. Building #17016-10000-13294.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13751	14041-20001-02285	16801 W SAN FERNANDO MISSION BLVD	91344	12	210B137   405	2682021006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.27215	-118.49829	(((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8KW AC UISNG 2 TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13752	18041-20000-09003	6630 W COLGATE AVE	90048	5	135B173    77	5510004030	R1-1-O-RFA	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.0701	-118.37154	pv1install roof mounted pv system sized 7.9kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13753	11041-10001-13050	1334 S CENTRAL AVE	90021	14	121-5A213   5	5130008042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.02855	-118.24651	ADD BREAK ROOM.  SUPPLEMENTAL FOR PLAN CHECK, WORK IS ALREADY PERMITTED.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13754	17041-10001-04261	10036 N ANDASOL AVE	91325	12	204B129   446	2734030035	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.25328	-118.51318	EXPEDITE PER APPLICANT REQUEST.(((((PC for a PV1 roof mounted installation in a single family home. New sysem consists of 40 MicroInverters rated at 327 Watts each. Total size of the system is 13.08KW. Also adding a 125A Load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13755	18041-10001-44823	14311 W VENTURA BLVD	91423	4	165B153   255	2265019001	(T)(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.15039	-118.44453	CHANGE TO AN APPROVED SET, CHANGE UNDER DELTA -1&2. CHANGE INCLUDES UPGRADING GENERATOR TO 200KVA AS WELL AS MISCELLANEOUS CIRCUITS. NOTE: PC ONLY. PERMIT FEES ARE COVERED UNDER 18041-10000-44823	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13756	14041-20000-25944	6200 N CANOGA AVE 3rd floor	91367	3	177B105   127	2149001035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.1833	-118.59719	TI to (E) commercial office space.  6,079 sq. ft.  Plan check for 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13757	14041-20001-12430	6223 E OAK CREST WAY	90042	14	157-5A231 212	5483017042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.12576	-118.18366	EXPEDITE PER APPLICANT REQUEST[[[PV1Installation of roof mounted solar array on SFD. System size: 3kW(1) SolarEdge SE3800A-US transformerless inverter(12) Renesola JC250M-24/BB pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13758	16041-20000-23116	11711 W PICO BLVD	90064	11	123B149   653	4260029033	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.03159	-118.44613	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF ART STUDIO. 958 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13759	16041-10000-21035	243 W 57TH ST	90037	9	108B201  1045	5101028011	R2-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	33.99088	-118.27768	PV1, solar installation 3 kW AC    (14) KU2656ZPA     (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13760	15041-10000-08519	11150 W SANTA MONICA BLVD SUITE 1550	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN SUITE 1550.  TOTAL SQUARE FOOTAGE 2494.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13761	14041-20001-28000	6616 S 3RD AVE	90043	8	102B189   325	4008003012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	33.97869	-118.32053	EXPEDITE PER APPLICANT REQUESTPV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13762	17041-10000-00022	501 E TERMINAL WAY	90731	15	018B205   127	7440027BRK		Harbor	PORT OF LA			9800.31	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	03/03/2023 12:00:00 AM	ADDRESS	33.7422	-118.26534	PC FOR POWER. REFEED 4160 V , 1200A 3PHASE SERVICE, ONE NEW 4160 V, 1200A 3P 4WSERVICE, AND ONE  2400V 2000A 3P. SCOPE INCLUDES REPLACEMENT AND RELOCATION OF EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13763	12041-10000-20666	1515 1/2 N WILCOX AVE	90028	13	147A187   100	5547017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.09849	-118.33114	TENANT IMPROVEMENT IN SMALL RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13764	17041-20000-41597	7565 W 80TH ST	90045	11	099B157   601	4114036021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	33.96386	-118.43029	pv1install roof mounted pv sytem with battery back up sized 2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13765	12041-20000-00136	6240 N CAHUENGA BLVD	91606	2	177B177   161	2414019024	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/08/2012 12:00:00 AM	ADDRESS	34.18425	-118.36142	Enphase inverters installed on roof of single family dwelling.  A variance to install Enphase M215 inverters was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13766	19041-20001-00391	6767 W FOREST LAWN DR #300	90068	4	162B181   617	5581028005	C1-1D-RIO	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.14432	-118.33993	Plan check for Title 24 only in existing space office Tenant Improvement. Total area: 3440 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13767	17041-20001-20036	654-656 N NORTH SPRING ST	90012	1	133-5A215 260	5408013007	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM			PC Approved	12/27/2017 12:00:00 AM	ADDRESS	34.05867	-118.23831	12.27.2017 - Plan check for modifications to approved set. Use of building was actually hotel, not office. Remove hotel unit areas from T24 calculations. Update floor plans and compliance forms. Recheck T24 only.======Plan check for energy only. TI to existing office on 2nd story of commercial building. New lighting (incl. emergency) and receptacles. 2,987sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13768	19041-10000-48930	384 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	04/08/2021 12:00:00 AM	ADDRESS	33.94339	-118.40887	POWER PLAN CHECK PER APPLICANT REQUEST FOR LAX CONTROL ROOM ADDITIONAL CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13769	19041-10000-14098	1580 W FRANCISCO ST	90501	15	057B193    31	7351021037	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	06/04/2020 12:00:00 AM		Permit Finaled	03/02/2022 12:00:00 AM	ADDRESS	33.8493	-118.30699	Power plan check for a medium voltage equipment system  with a scope of 5KV 600Amp service including (1) 1000KVA step transformer and (1) 1600-Amp 480/277V distribution panel. Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application # 19041-10000-14101	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13770	16041-20000-29136	3650 E OLYMPIC BLVD Unit A	90023	14	118-5A227 227	5191024011	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.01861	-118.1992	Plan check for power only. Adding new 800A distribution board fed from meter A to feed (4) new empty panelboards and refeed existing panelboards/distribution equipment on 3rd and 4th floors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13771	16041-10000-28079	1600 S MAIN ST	90015	14	124-5A207 383	5133014001	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Issued	09/23/2016 12:00:00 AM	ADDRESS	34.03342	-118.26249	PC FOR POWER ONLY. NEW 600A 120/240V SERVICE UPGRADE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13772	14041-10000-06943	11715 W BELLAGIO ROAD 1-23	90049	5	141B145   477	4368014019	[Q]R3-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Public Safety Only			03/14/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	34.07869	-118.46956	FIRE ALARM FOR 3 STORY APPARTMENT BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13773	17041-10002-14285	1501 N SUMMITRIDGE DR	90210	5	147B157   193	4355005039	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM			PC Approved	05/21/2018 12:00:00 AM	ADDRESS	34.09868	-118.41997	[[[5/21/18 CHANGES TO APPROVED SET. DELTA 2 CHANGES. ADDITION OF COMBO SMOKE DETECTORS ]]]REVISED SINGLE LINE DIAGRAM TO SHOW THAT ATS IS RATED 400A  AND PANEL E IS RATED 400A WITH 225A MAIN CB. (((((((Plan check for power.  Remodel and addition to single family dwelling.  New 800 amp 208/120 volt service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13774	17041-20003-42262	8755 W YATES ST	91040	7	204B189   414	2546002019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.25675	-118.32433	05-22-2018 Changes to an approved set of plan. Changes include remove load center and Gateway relay. Paln check only$0 plan check fee due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13775	10041-10000-01521	6801 W HOLLYWOOD BLVD D2-249	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM	03/15/2010 12:00:00 AM		Permit Finaled	04/15/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I. for existing commercial building (Aldo).  Install new lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13776	18041-10000-40823	9545 N RESEDA BLVD STE 9	91324	12	201B125   431	2763036008	(T)(Q)C2-1VL, C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Issued	10/25/2018 12:00:00 AM	ADDRESS	34.2439	-118.53634	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13777	16041-10001-25706	3411 S CRENSHAW BLVD	90016	10	120B185   977	5046001038	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM			PC Approved	08/07/2017 12:00:00 AM	ADDRESS	34.02516	-118.33536	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO LIGHTING FIXTURES, PANEL REMOVAL, CIRCUIT LOADS REARRANGED, AND PROVIDED UPDATED FLOOR PLANS AND T24 DOCUMENTS. PC FOR CHANGES CLOUDED. NO ADDITIONAL LOADS. PERMIT COVERED UNDER MASTER. THIS IS PC ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13778	13041-20000-18867	16101 W VENTURA BLVD	91436	5	168B141   539	2260023057	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.15658	-118.48382	existing retail to retail. new lighting. pc for t24 energy only. total area 1166 sqft. children salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13779	13041-20000-31893	12845 W NORTH SEAGLASS CIR	90094	11	102B161  1223	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	33.97462	-118.41896	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13780	18041-10000-41636	767 S ALAMEDA ST 280	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	**This is plan check only, permit is obtained under 18041-90000-44865**  TITLE 24 PLAN CHECK FOR T.I. OFFICE SCOPE INCLUDES EQUIPMENTS AND LIGHTING FIXTURES WITH 2151 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13781	16041-10000-00681	600 WORLD WAY SPACE 681	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING, LAX T6 (STARBUCKS). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA ISI 813 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13782	13041-10000-02928	254 S OCEANO DR	90049	11	132B141   465	4404033009	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.05803	-118.47264	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. 2 STORY UNIT. TOTAL OF 26 PANELS. ONE CENTRAL INVERTER. TOTAL SYSTEM SIZE OF 5.72 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13783	11041-20000-11608	14726 W LULL ST	91405	6	186B149   141	2210027034	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	09/20/2011 12:00:00 AM	ADDRESS	34.2092	-118.45407	Upgrade service to 600 Amp service for existing building.  Remove existing 400A service. Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13784	14041-20000-19831	10231 N TUNNEY AVE	91324	12	204B117   237	2726009009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Expired	08/25/2016 12:00:00 AM	ADDRESS	34.25657	-118.55815	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13785	18041-20001-05110	2720 S GREENFIELD AVE	90064	5	123B157   742	4256020043	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM			PC Info Complete	06/13/2018 12:00:00 AM	ADDRESS	34.0328	-118.42734	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REDUCTION OF ELECTRICAL EQUIPMENT TO 1 SUB-PANEL WITH EXISTING PV AND NEW TESLA POWERWALL 18041-20000-05110 addition of (1) tesla powerwall to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13786	15041-10001-38985	701 E 3RD ST	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	PIN	34.04581508	-118.23784015	{PC only}  Changes on approved set. Refeeding ATS3 from New 250A breaker. Changes noted on Delta-1.Permit under 15041-10000-38985<<TI TO AN EXISTING COMMERCIAL BUILDING.  RELOCATING 16 PANELS INTERSECTING EXISTING FEEDER FROM EXISTING SWITCHGEAR.  NEW OPTIONAL STANDBY GENERATOR 80KW.  PLAN CHECK FOR POWER ONLY.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13787	17041-10000-08110	18019 W VENTURA BLVD	91316	5	171B125   350	2162005131	(Q)C2-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.16485	-118.52493	T24 ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES 16305 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13788	15041-10000-28441	9301 N BORDEN AVE	91352	6	198B173    82	2408039012	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.23787	-118.36951	T24 ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE THEM WITH NEW LED LIGHT FIXTURES. TOTAL AREA 16095 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13789	17041-10000-38257	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			10/24/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Closed	07/16/2020 12:00:00 AM	ADDRESS	34.06047	-118.29555	PC for power for new temporary power. Intalling new 277/480V 600A service and switchboard, new circuits, equipment. Site is on methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13790	15041-10000-06828	107 S RAMPART BLVD	90057	13	136-5A203 103	5155023006	R4-1	Central	Westlake	Greater Echo Park Elysian		2086.20	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.06927	-118.27722	INSTALLING ON ROOF OF SFD, PHOTOVOLTAIC SYSTEM 3.240 KW USING 12MODULES/12 ENPHASE MICROINVERTERS M250. STD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13791	12041-10000-22534	3255 W WILSHIRE BLVD	90010	10	135B197  1185	5502026020	C2-2, C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00, 2123.03	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.06195	-118.29324	TENANT IMPROVEMENTS IN OFFICES # 1150PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13792	16041-10000-19349	11811 S TEALE ST	90230	11	105B165   298	4220006075	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM			PC Info Complete	06/13/2016 12:00:00 AM	ADDRESS	33.98545	-118.40128	PC for T-24 only.  Install Triple Stacker Car Lift on an (E) single story office build., install outdoor lightings. New connected load les than 400A.  Car lift submitted per LADB Reserach Report NO: 930532.  Total area for T-24 is  5,254 sq.ft.B# 16020-10000-01599	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13793	14041-10000-13984	622 S ANDERSON ST	90023	14	126A219   105	5171006012	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.03834	-118.22362	P.C for power and energy. PROPOSED DEMISING WALLS TO DIVIDE TENANT SPACES (INTERIOR) into 8 spaces OF EXISTING 14,745 S.F. WAREHOUSE SHELL ONLY. Please verify the S.F. of area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13794	16041-10000-45533	20000 S VERMONT AVE	90502	15	057B197   153	7351033061	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	33.84914	-118.29027	Full Plan check to a new 3 story office/warehouse building. New service rated at 600 A 277/480V. Total area: 38,197.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13795	13041-10000-33308	2253 E WASHINGTON BLVD	90021	14	118-5A217 120	5167019043	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	11/27/2013 12:00:00 AM	ADDRESS	34.01912	-118.23118	PLAN CHECK FOR T24, ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLOURESCENT FIXTURES.  AREA 13719 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13796	14041-10004-32844	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.07583	-118.37407	02/11/2016Changes to an approved set of plans, Shophouse. Note changes on delta 11. Changes include the calculation and revision for fault current.(((changes to an approved set. changes include two new fixtures, the splitting of an 800amp switchgear to two 400amp distribution boards. note changes on delta 8 and 9. )))(((Minor revisions to approved set.  Change of lighting fixture and relocation of fixtures.  Delta 7 revisions.)))(((T24 and power plan check.  Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects. Area = 1849 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13797	17041-10000-45091	1716 N CAHUENGA BLVD	90028	13	148-5A187 111	5546005029	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.10213	-118.32938	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13798	19041-10000-50150	3 S CHESTER PL	90007	1	123A203   124	5124029016	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	02/13/2020 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.03141	-118.27736	NOTE: PERMIT FEES ARE $0 DUE TO AB 1414.( E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 2000 AMPS. INSTALLATION INCLUDES: -INSTALL (1) 100 KW (SE100KUS), (1) 66.6 KW (SE66.6KUS), (1) 43.2 KW (SE43.2KUS), (1) 14.4 KW (SE14.4KUS), AND (2) 7.6 KW (SE7600A-US) INVERTER(S)-(1) 100 AMP, (1) 200 AMP,  (1) 400 AMP, AND (1) 600 AMP PANEL-(754)  (Q.PEAK DUO L-G5.3) MODULE (S) -(379) OPTIMIZER(S) (SOLAREDGE P850)SYSTEM SIZE: 301.6 KW DC;  231.8 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13799	13041-10000-30088	23424 W CALIFA ST	91367	3	174B093    29	2041004004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.17721	-118.63725	PV1, Install 10.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 43 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13800	10041-10000-08385	6356 W HOLLYWOOD BLVD	90028	13	148-5A187 169	5546008020	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	08/26/2010 12:00:00 AM	ADDRESS	34.10144	-118.32846	T.I. to existing building (Night Club).  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13801	18041-10000-19524	8409 N LAUREL CANYON BLVD	91352	6	192B165   892	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.22356	-118.39666	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13802	14041-10000-10705	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	T24 FOR EXISTING RESTAURANT IN HIGHRISE BUILDING. SCOPE OF WORK IS ON THE FIRST FLOOR. NO UNIT EQUIPMENT SHALL BE USED IN THIS PROJECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13803	19041-10000-01001	2155 W BELLEVUE AVE 1-19	90026	13	138A205    54	5402039024	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.10	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			Reviewed by Supervisor	02/05/2019 12:00:00 AM	ADDRESS	34.07366	-118.26799	PLAN CHECK FOR POWER ONLY FOR SERVICE UPGRADE FOR EXISTING APPARTMENT RATED AT 800A 120/240 SINGLE PHASE WITH REPLACEMENT OF ALL UNIT PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13804	14041-10000-13829	6900 N RANCHITO AVE	91405	2	183B153   882	2216019022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.1959	-118.43552	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 4.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13805	18041-30000-16856	6301 N OWENSMOUTH AVE 6TH FLR.	91367	3	177B105   123	2146029016	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Issued	07/11/2018 12:00:00 AM	ADDRESS	34.18467	-118.60176	Plan check for T24 only, Tenant improvement to (e) office 6th floor in a high rise building. Install new lights and receptacles. New circuits fed from existing panels. New loads < 200A. Total area: 19,935 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13806	17041-20000-40715	12293 N WOODLEY AVE	91344	12	219B137   160	2609014036	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.29331	-118.49138	PV1. CONNECTED TO EXISTING SOLAR SYSTEM.  ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.8 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13807	15041-20000-19303	23018 W BURBANK BLVD	91367	3	174B097   603	2042003016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Expired	07/18/2017 12:00:00 AM	ADDRESS	34.17172	-118.62837	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 7.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13808	15041-10000-21310	6745 N FALLBROOK AVE	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.19253	-118.62413	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL. NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1930.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13809	10041-20000-15699	9615-9619 S MAIN ST	90003	8	093A203   193	6053009015	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	33.94871	-118.27403	Plan check Outdoor T-24 Energy for school parking lot.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13810	16041-20001-21240	10354 W DIAMOND ST LOT 18	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC in Progress	06/27/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13811	13041-10000-35131	1625 W SUNSET BLVD	90026	13	139-5A209 119	5419029030	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	03/12/2014 12:00:00 AM		Issued	03/12/2014 12:00:00 AM	ADDRESS	34.07728	-118.25803	PLAN CHECK FOR POWER AND ENERGY. REMODELING A RETAIL MARKET TO A GROCERY MARKET.(BEHROOZ)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13812	16041-10000-26517	1017 N ILIFF ST	90272	11	129B129   602	4423011021	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM			PC in Progress	08/24/2016 12:00:00 AM	ADDRESS	34.04815	-118.51934	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF STORAGE. TOTAL SYSTEM SIZE IS 6KWac.(29)MODULES-KYOCERA#KU2656ZPA(1)INVERTER ABB PVI-6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13813	12041-20000-03692	6303 N OWENSMOUTH AVE 10TH FLOOR	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM			PC Approved	03/02/2012 12:00:00 AM	ADDRESS	34.18474	-118.60182	10TH FL. T.I.ENERGY, EMERGENCYFire/ LIFE SAFETY IS BY OTHERS  12041-20000-04401INTERIOR NON STRUCTURAL T.I. ON 10TH FLOOR TO MODIFY PANTRY / LOUNGE AREA AND INSTALL NON BEARING PARTITION WALLS TO SUBDIVIDE (E) OFFICE INTO 4 OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13814	19041-10000-08270	23701 W ROSCOE BLVD	91304	12	192B089    77	2005021019	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.21939	-118.64417	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR)- T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13815	19041-20000-40245	11956 N SONOMA WAY	91326	12	216B117    22	2872004001	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Issued	10/04/2019 12:00:00 AM	ADDRESS	34.29013	-118.55339	Plan check for Energy storage system install into existing PV system, Energy storage system size: 13.5KWh , new sub-panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13816	19041-10000-17650	3000 W 6TH ST #100	90020	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center-Koreatown		2111.20	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM			PC Approved	05/10/2019 12:00:00 AM	ADDRESS	34.06355	-118.28741	TI IN AN EXISTING OFFICE IN SUITE #100.INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13817	16041-10000-37884	6255 W SUNSET BLVD 1ST-2ND FLOOR	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan Check for T24 for existing office space. Installing new lights and receptacles. **NEW CONVENIENCE STAIRS BETWEEN 1ST AND 2ND FLOORS AND TENANT IMPROVEMENT TO EXISTING OFFICE SPACES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13818	12041-10001-03798	20946 W DEVONSHIRE ST	91311	12	204B109   173	2747001091	C2-1, CR-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			PC Approved	08/30/2012 12:00:00 AM	ADDRESS	34.25708	-118.59006	revised permitted set of plans- no changes to the lighting system; single line is revised to show that a single 120/240v 3ph 4w swtchboard replacing the 1ph and 3ph switchboardsTI in an existing office building. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13819	17041-10000-19848	15156 W TRAIL VIEW CT	91342	7	216B145   336	2611039026	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.29096	-118.46306	PC for new Tesla Powerwall2 connecting to existing house panel and exisiting solar system. PV solar permit under 16041-90000-14020.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13820	19041-10000-15523	527 E VERNON AVE	90011	9	112-5A207  53	5113014016	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2285.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	34.00406	-118.26581	PLAN CHECK FOR T24 ONLY, T. I.  OF EXISTING  1200 SQ FT RESTAURANT SPACE TO DONUT SHOP.INSTALL (3) NEW PANELS CONNECTED TO AN (E) 400A BREAKER AT THE 600A DIST. BOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13821	13041-10000-34609	13929 W DEL SUR ST	91331	7	210B153   507	2616023007	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.27241	-118.4366	Roof mounted PV system with 6.25 KW for single family dwelling with a tranformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13822	14041-10000-16519	9034 N BURNET AVE	91343	7	195B145   635	2654006027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.2348	-118.46302	Full plan check for power and lighting.  Total area = 25,899 sq. ft.Construction of new public charter middle school and site development. fire alarm variance has filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13823	15041-20002-16378	940 S FIGUEROA ST basement-5th floor	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.04538	-118.26335	05/04/2016 Changes to an approved set of plans. Changes have been made to provide power to electrical equipment. Transformer has been added to change voltage class to power said equipment.[[[[ 2/18/16  CHANGES TO APPROVED SET. ADDITION OF FIREPUMP AND JOCKEY PUMP TO THE SYSTEM REQUIRED BY MECHANIAL]]]]]]]*****Previous Work Description*****New service upgrade and distribution equipment for assembly occupancy. new design. This is core and shell clear out of existing building. TI package will be submitted at a later date. per building submittal, PC is accordance to 2008 building efficiency standards.project is in methane buffer zone. NOT A HIGHRISE PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13824	14041-20000-18977	940 S TIVERTON AVE 1-48	90024	5	135B153   582	4360001183	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			07/15/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.06266	-118.4425	33.5KW PV1 roof-mounted system with (3) SolarEdge SE10k-A-US inverters, (110) Conergy PE 305P modules and SolarEdge P400 power optimizers.FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13825	18041-10000-41457	21100 S WESTERN AVE	90501	15	054B193   598	7349002035	M1-1VL, P-1VL, RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Issued	01/25/2019 12:00:00 AM	ADDRESS	33.83941	-118.30903	PC FOR POWER ONLY, 2 ROOF TOP AHU, 2 INLINE PUMPS, AND 2 FLUID COOLER PUMPSREPLACE 1 FLUID COOLER FAN, REMOVE 2 COMPRESSORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13826	09041-20003-24723	15301 W LANARK ST	91406	6	189B145    41	2654037029	R4-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Apartment			05/21/2012 12:00:00 AM			PC Approved	06/22/2012 12:00:00 AM	PIN	34.2183683	-118.4669973	Modification to feeder sizes and length for units and house no change in panel loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13827	17041-20000-13282	15201 W VOSE ST	91405	6	183B145  1132	2220022022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.19856	-118.46416	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13828	12041-20000-02743	11934 W VALERIO ST	91605	6	186B165   545	2317015004	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.20472	-118.39334	Ice cream factory expansion ; add new compressors, freezers, panel, and transformer.  This is the restamp of a previously approved set of plans.  Only load changes occurred on the panel D schedule in circuitry.  Demand was same demand as on the original approved set of plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13829	19041-10000-22719	9255 N SAN FERNANDO ROAD	91352	6	198B169   128	2631003028	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.23743	-118.39209	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13830	17041-20000-22061	3207 W LOS FELIZ BLVD	90039	13	157-5A205   7	5593002907	OS-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM			PC Approved	06/29/2017 12:00:00 AM	ADDRESS	34.12331	-118.2693	Plan check for energy only. Lighting for outdoor patio for restaurant. 600sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13831	19041-20000-05045	6300 N CANOGA AVE STE 1750W	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.18492	-118.59722	T-24 ONLY PC FOR A TI OF AN OFFICE SPACE IN A HIGHRISE. SUITE #1750. SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1757 SQ.FTB# 19016-40000-03376	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13832	18041-20002-06916	19307-19327 W VENTURA BLVD	91356	3	174B117   304	2163001018	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	34.17284	-118.55387	08/14/2018 Plan check for Title 24 only. Project site is an existing 2-story building. Project scope is outdoor lighting. Total lighting area = 5,397 sq. ft. Feeder voltage drops for replaced feeders have been verified.*****Previous Work Description*****Supplemental permit to increase scope of permit to replacement of fire-damaged feeders.  (((REPLACEMENT OF 40 FIXTURES, LIKE FOR LIKE REPLACEMENT. ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13833	11041-10000-23964	800 W WORLD WAY Terminal 8-Space 8C	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	1st time tenant for Terminal 8 at LAX, Space 8C.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13834	13041-20000-31257	3606 W 6TH ST	90005	10	135B193   873	5502032005	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	11/08/2013 12:00:00 AM	PIN	34.0633338	-118.3007217	T24 TI FOR EXISTING BAR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13835	18041-10000-02726	1627 W 35TH PL	90018	8	120B193   985	5041007013	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.02383	-118.30683	"PC for 3.8kW (AC) rooftop solar system for SFD. Installing 12 modules (3.54kW(DC)) with optimizers and  3.8kW inverter.""COMPLY WITH DEPARTMENT ORDER effective date11/17/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13836	09041-10001-24320	10747 W MAGNOLIA BLVD	91601	2	171B177   600	2416024009	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			06/13/2011 12:00:00 AM			PC Approved	06/13/2011 12:00:00 AM	ADDRESS	34.16505	-118.36517	REVISIONS TO THE SINGLE LINE DIAGRAM ON SHEET E0.3: MOST OF CONDUITS FOR THE  FEEDERS FROM RSW AND RSE TO THE APARTMENT PANELBORDS  WERE REDUCED AS THE FEEDERS WERE CHANGED  TO TYPE  XHHW-2 COBDUCTORS . FEEDER SIZES REMAINED THE SAME((((((((((Plan check power and energy for new 126 unit apartment building.  A variance to separate the electrical and fire alarm system permit and approval was submitted on January 27, 2011.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13837	12041-10000-16637	4847 N FULTON AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	11/08/2012 12:00:00 AM	ADDRESS	34.15853	-118.42287	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13838	14041-10000-23708	13031 W JEFFERSON BLVD Suite 300	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	PLAN CHECK FOR ENERGY ONLY. LIGHTING DONE IN 2 BATHROOM STALLS AND 1 CLOSET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13839	14041-20001-26180	19153 W COMMUNITY ST	91324	12	192B121   520	2784013015	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.22287	-118.5509	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(30) KYOCERA KD255GX MODULES(30) POWER OPTIMIZERS(1) SOLAR EDGE SE6000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13840	13041-20000-09523	1794 W 36TH ST	90018	8	120B193  1244	5041014001	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.02271	-118.31167	PV1 MICROINVERTER STANDARD PLAN. ROOF MOUNTED. SYSTEM SIZE IS 4KW. ENPHASE MICROINVERTER WITH TRINA SOLAR 240.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13841	17041-30000-04005	1511 S ABBOT KINNEY BLVD 1st Floor	90291	11	108B145  1406	4241036012	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	33.99033	-118.46425	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 805 sq. ft.Note: Building permit has been pulled under 16016-10000-24084	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13842	19041-20000-41188	12003 S MAIN ST	90061	15	084B201  1217	6132026030	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2414.00	Electrical	Electrical	Apartment			10/21/2019 12:00:00 AM	05/29/2020 12:00:00 AM		Permit Finaled	01/11/2022 12:00:00 AM	ADDRESS	33.92336	-118.27421	1200A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.  Building permit under 19010-10000-04513.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13843	11041-20000-14440	8320 W MELROSE AVE	90048	5	141B173   485	5528015028	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	07/12/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	PIN	34.0833936	-118.37106779	PLAN CHECK T24 ENERGY INDOOR AND OUTDOOR FOR OFFICE AND GARAGE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13844	17041-10002-23317	3680 W WILSHIRE BLVD BASEMENT	90010	10	132B193    65	5093006028	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.06149	-118.30603	Supplemental PC for revisions in the emergency lights in the basement in Suite #B01. Changing Unit Equipment with internal batteries to Emergency Lights connected to the Emergency Panel in the High Rise Building. T-24 Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13845	15041-10001-21053	720 N ALEXANDRIA AVE	90029	13	141B197   395	5538008023	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM			PC Approved	05/02/2016 12:00:00 AM	ADDRESS	34.08427	-118.29771	EXPEDITED RSES PERMIT PER APPLICANT REQUEST.<<PV2, INSTALL 21.200KWDC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE WITH THE MAIN SERVICE PANEL.(80) MODULES: LG MONO X NEMO LG65S1-B3(5) INVERTERS : SMA AMERICA SB 3000TL-US-22AND 3800 AND 5000 TL-US-22>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13846	17041-10000-24723	3831 S HUGHES AVE 6	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.02242	-118.39823	PC for addition of three new relay devices to existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13847	10041-20003-11314	3233-3237 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035012	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	03/29/2011 12:00:00 AM	ADDRESS	34.02889	-118.37311	Changes from previously approved plans.  Changes include relocate switches, emergency lighting, and motion sensor.  Plan check for energy only.Note: Permit issued under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13848	16041-10001-42038	5250 W SANTA MONICA BLVD #306	90029	13	144B193   736	5537020029	[T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.09066	-118.30496	PC FOR MEDICAL OFFICE. POWER ONLY. PERMIT ALREADY ISSUED, THIS APPLICATION IS PLAN CHECK ONLY FOR ARTICLE 517.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13849	12041-10000-06305	1518 W PALOS VERDES DR NORTH BLDG G	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77936	-118.30417	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building G. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13850	18041-10001-12192	900 W OLYMPIC BLVD #F51	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	05/11/2018 12:00:00 AM	ADDRESS	34.04526	-118.26611	***Fee Expedited per applicant*** NEW SOLAR ROOF SYSTEM ON A HIGH RISE RITZ HOTEL/RESIDENTIAL. THIS PV IS ONLY FOR (1) UNIT PENTHOUSE (#F51). INSTALL (10) MODULES, (1) CENTRAL INVERTER SE7600A-US, (1) 10Kva TRANSFORMER TO STEP UP THE VOLTAGE FROM 120/240V TO 208V. SYSTEM INTERCONNECT AT 600A SUBPANEL. SYSTEM SIZE AT 7.6 KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13851	14041-20000-05049	5920 N WINNETKA AVE	91367	3	177B113   217	2153004013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.17833	-118.57094	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13852	19041-20000-32839	1755 N CORREA WAY	90049	11	135B137   331	4426005014	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.06656	-118.49697	Plan  check for installed Energy stroage system, installed Tesla PowerWall 2.0(2) 13.5kWh into existing PV System. Total Energy Storage System size: 27.0KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13853	19041-20000-19031	1039 N MISSION ROAD	90033	14	133-5A221  65	5410001019	[Q]M2-1-RIO	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM			Verifications in Progress	10/04/2019 12:00:00 AM	ADDRESS	34.05992	-118.21562	Full PC for power and energy. Change of use from manufacturing to hydroponics and manufacturing with retail sale and extensive TI work.  (E) 1600A 480Y/277V 3ph-3w service with new downstream distribution and loads. Total affected area is 15181 Sq. Ft.   Building permit under 18016-20000-39748.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13854	19041-10000-20490	19436 W VENTURA BLVD	91356	3	174B117   331	2163002016	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.17256	-118.55704	Plan check for a fire alarm system located in a one story commercial building. Scope includes (1) fire alarm panel, and (24) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13855	10041-10000-12180	7300 W HOLLYWOOD BLVD	90046	4	147B181   182	5550016024	[Q]R5-1	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Commercial			06/25/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	11/01/2010 12:00:00 AM	ADDRESS	34.10144	-118.34913	TI in an exiting commercial builing on the 1st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13856	17041-20002-16465	3315 N VERDUGO ROAD	90065	1	153A215   307	5457022028	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.11215	-118.23612	[[[7/18/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. REVISION TO THE SINGLE LINE DIAGRAM TO SHOW 400 AMP SERVICE PANEL]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13857	18041-10000-08040	19350 W NORDHOFF WAY	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.23523	-118.55518	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 224225 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13858	14041-20001-31022	15300 W VALLEY VISTA BLVD	91403	4	166-5A145 216	2281005006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.14874	-118.46757	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.(34) SUNPOWER 327WATTS MODULES(2) SUNNYBOY 5000TL INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13859	19041-10000-52591	19191 S VERMONT AVE #200	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	07/13/2020 12:00:00 AM	ADDRESS	33.85656	-118.29099	Energy plan check for an office T.I located on the second floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 5,674 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13860	16041-20000-18198	5851 S VERMONT AVE	90044	9	108B197  1631	6003005012	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	33.98816	-118.29164	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SHEIK SHOE STORE. 7130 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13861	18041-20000-36973	9120 W HILLSBORO DR	90034	5	126B169   662	4302010026	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.0415	-118.38951	Plan check for PV roof mounted system, system  size: 6.6KW DC, 6.07KW AC with 20 modules and 20 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13862	19041-10001-31007	6725 W SUNSET BLVD	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.09814	-118.33717	CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES CHANGING LAYOUT OF LIGHTING PLAN, T24 FORMS HAVE BEEN UPDATED ACCORDINGLY. ALL CHANGES ARE CLOUDED UNDER DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13863	19041-20000-09754	777 S FIGUEROA ST FLR 48, 49	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Remodel of restrooms on 48th and 49th floors.  Plan check for energy.Building permit issued under 18016-10000-38224.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13864	15041-20000-17822	1515 S WESTGATE AVE (1-19)	90025	11	126B145   506	4263033006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			06/09/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.04163	-118.45883	Plan check for New 19 units appartment. 1,000A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13865	13041-20000-19908	7046 W HOLLYWOOD BLVD	90028	13	147B181   203	5548007010	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.10136	-118.3431	New restaurant.  Install 600A panels.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13866	13041-10000-01617	14006 W RIVERSIDE DR 249B	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	T24 FOR NEW RESTAURANT IN MALL SPACE. TI OF EXISTING RESTAURANT. NO CHANGE OF USE. T24 FOR 685 SQ FT. STORE #2093	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13867	19041-30000-09339	2029 S CENTURY PARK EAST 3rd Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is common area restrooms on the 3rd floor. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13868	14041-20000-19126	11315 N MONOGRAM AVE	91344	12	210B137    51	2681014010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.27598	-118.49249	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING MICROINVERTER ENPHASE M250. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13869	19041-20000-44780	8050 N DARBY AVE	91335	12	189B125   174	2102004021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.21714	-118.5333	PV1. INSTALL 4.56 KW DC PV SYSTEM WITH (24) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13870	15041-10000-42646	732 S SPRING ST	90014	14	127-5A211 161	5144015029	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.04346	-118.25305	Full Plan check for power and energy for a new apartment building, 24 stories high rise, 300 units. Total Sq ft = 308000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13871	12041-20000-11444	5521 S GROSVENOR BLVD	90066	11	105B161  1004	4211005015	M2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	33.98101	-118.41304	New 800A service and 200KW emergency generator in Methane Zone.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13872	18041-10000-37222	1503 S ABBOT KINNEY BLVD	90291	11	108B145  1382	4241036008	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	33.99042	-118.46462	INTERIOR ALTERATIONS ON THE 2ND FLOOR OF EXISTING BUILDING. TITLE 24 ENERGY ONLY (2750 SQR FT).BLDG PERMIT: 18016-10000-15528	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13873	10041-10001-16498	1930 W WILSHIRE BLVD	90057	1	132A203    41	5142002019	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.05713	-118.27464	INSTALL A NEW 230KW PV SYSTEM IN THE PARKING AREA.((((((((((((  3-30-11 Addition of 300 kva transformer and two diconnects to existing PV system ))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13874	17041-20001-23678	6535 N TONY AVE	91307	12	180B089   530	2033007010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.18938	-118.64503	EXPEDITED PER APPLICANTS REQUEST.INSTALLATION OF BATTERY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13875	15041-20000-32924	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM			PC Info Complete	10/29/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for power and energy.  Addition of substation, ATS, UPS, and distribution equipment.  medium voltage equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13876	12041-10000-13104	2915 W LOS FELIZ BLVD	90039	13	157-5A207 373	5594006021	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	12/12/2011 12:00:00 AM	ADDRESS	34.12679	-118.26282	T-24 lighting plan check for new Chase Bank.  Interior and exterior lighting.  Total load is 329A  and occupancy load is less than 99, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13877	18041-20000-34280	423 E 7TH ST	90014	14	127-5A211 306	5148024027	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	04/25/2023 12:00:00 AM	ADDRESS	34.04159	-118.24777	Plan check for Service upgrade to 800A Service, no change to use(Single Resident Occupancy, Hotel) 200 units Hotel 4 story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13878	19041-10000-21780	15303 W VENTURA BLVD 5TH FLR	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT THROUGHOUT 5TH FLOOR OF (E) OFFICE BUILDING - NON HIGHRISE BUILDING WITH NO BACKUP GENERATOR PER APPLICANT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13879	11041-20000-15410	333 S HOPE ST #3625	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check T24 Energy/Emergency suite #3625 office TI. Permit under #11041-90000-13783	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13880	18041-10000-07974	816 S SANTA FE AVE	90021	14	123A217    45	5166003013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.03293	-118.22982	PC FOR TITLE 24 ENERGY ONLY FOR TENANT IMPROVEMENT TO (E) MANUFACTURING BUILDING.SCOPE INCLUDES NEW CIRCUITS AND LIGHTS. TOTAL  AFFECTED AREA 970 SQ. FT.B#17016-10000-35935	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13881	18041-10000-07054	10360 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.2587	-118.57962	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 193325 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13882	18041-10001-06922	100 WORLD WAY T132	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION UNDER DELTA 5 AND 6 ONLY. SCOPE INCLUDES NEW (4) CIRUCUITS AND REVISIONS TO LIGHTING AND T-24 FORMS. (((FIRST TENANT IN NEW RETAIL SPACE AT LAX TERMINAL 1 CONCOURSE LEVPLAN CHECK FOR POWER AND LIGHTING)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13883	11041-10000-26661	2130 E 1ST ST	90033	14	127-5A223 122	5183008901	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Public Safety Only			12/14/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.04433	-118.21291	INSTALLATION OF FIRE WARNING SYSTEM IN A 2-STORIES COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13884	15041-20000-19267	15213 W FRED WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.20917	-118.46464	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 3.6KW  CENTERAL INVERTER SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13885	18041-20001-24822	5757 W WILSHIRE BLVD #P2	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			PC Approved	11/28/2018 12:00:00 AM	ADDRESS	34.06259	-118.35341	Revisions to approved set of plans.  Approval for delta-4 modifications only.  Completion of 30-day metering per filed request for modification of building ordinance.  Operating room architectural layer revised.  (((Plan check for power and energy for outpatient medical office space with operating room. Total area: 1827 sq ft. Modification filed to complete 30-day existing demand reading and resubmit to plan check. Building permit filed under 18016-20000-19914.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13886	18041-20000-12897	12744 N SAN FERNANDO ROAD Bldg 2	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for Title 24 only in existing warehouse convert to office space. Add new lighting new controls to existing panels. Total area: 9612 sq ft.B#17014-20000-06065, 16016-20000-19361	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13887	17041-10001-31277	201 WORLD WAY	90045	11	090B165    76	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM			PC Approved	06/22/2018 12:00:00 AM	ADDRESS	33.94469	-118.40336	This is supplement plan check only,  revise light fixtures D1 from 13 Watt to 17 watt, revise T24 calculation accordingly.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13888	17041-10001-37202	10250 W SANTA MONICA BLVD # 2380	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Supplemental PC for changes to water heater, waffle maker and removal of sandwich machine loads. All changes clouded on pg E-3.THIS IS PLAN CHECK ONLY PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13889	11041-20000-18155	555 W 5TH ST 17th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I. on the 17th floor of a high rise building.  Plan check is for energy only. Installation does not exceed 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13890	15041-10000-22001	9070 N VARNA AVE	91331	6	195B157    42	2640004012	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.23494	-118.43235	PV1, INSTALL 3.924 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE .(12) MODULES: SUNPOWER SPR327NE -WHT-D(1) INVERTER: ABB PVI -3.0-OUTD-S-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13891	15041-20002-38556	20790 W NORDHOFF ST #4	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	4.27.2016 - Plan check for modifications to approved set. Remove isolated ground for receptacles (sheet E2.1). Add service light and receptacle for walk in cooler (sheet E2.2). Delta 7 changes.====02/24/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Changes have been made to reflect on-field installation. Additional equipment has been installed to allow the disaggregated measurement of electrical load.*****Previous Work Description*****PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT. (THE SHELL WAS BUILD FOR RETAIL PUROSE). TOTAL AREA 1254 SQ FT.B# 15016-10000-23306	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13892	18041-20000-46395	248 S VAN NESS AVE	90004	4	135B189   100	5516010002	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.06976	-118.31543	Plan check for PV roof mounted system, system size: 12.54kW DC, 11.53kW AC CEC with 378 PV Modules and 38 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13893	19041-20000-18059	12125 W VAN NUYS BLVD	91342	7	216B165   216	2531033003	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1042.04	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.28467	-118.39693	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6.2KW DC/4.8KW AC. SCOPE OF WORK INCLUDES (20) MISSION SOLAR 310W PV MODULES AND (20) ENPHASE IQ7 MICRO INVERTERS AND A IQ COMBINER 3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13894	18041-10000-46075	811 S CENTRAL AVE	90021	14	124-5A213 475	5146017005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	05/02/2022 12:00:00 AM		Permit Finaled	06/29/2022 12:00:00 AM	ADDRESS	34.03337	-118.24374	$0 permit fees due to department error, Permit fees have been paid for under supplemental application, 18041-10001-46075. FULL PLAN CHECK FOR A NEW WAREHOUSE. SCOPE OF WORK INCLUDES NEW 2000AMPS SERVICE 208Y/120V, 3 PHASE. CIRCUITS EQUIPMENTS AND LIGHTIN, TOTAL EFFECTED AREA 22833 SQFT.BLD# 18010-10000-04057	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13895	19041-20000-09700	618 S VAN NESS AVE	90005	4	135B189   927	5504018011	RD3-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			03/22/2019 12:00:00 AM			PC Info Complete	10/01/2019 12:00:00 AM	ADDRESS	34.06245	-118.31518	600A Service feeding 2 buildings, Building 2 of 2. Plan check only, permit issued under 18041-20000-04920	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13896	11041-10000-00703	732 E 10TH ST Unit 107	90021	9	124-5A211 354			Central				2260.00	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.03504	-118.25099	Plan check for electrical and T-24 for space 107.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13897	18041-10000-31231	8940 N CORBIN AVE	91324	12	195B117    34	2783025080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.23325	-118.56211	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13898	18041-20000-46421	9172 N COLUMBUS AVE	91343	7	198B145   303	2656024037	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.2376	-118.4653	Plan check for PV roof mounted system, system size: 9.9kW DC, 9.106kW AC with 30 with 30 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13899	11041-20000-02680	6201 N IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	PIN	33.93615744	-118.3860948	Plan check T24 energy/emergency lighting for TI in existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13900	19041-10000-42065	3900 W 6TH ST	90020	10	135B193   885	5503030001	C2-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Issued	10/16/2019 12:00:00 AM	ADDRESS	34.06338	-118.30809	Plan check for Fire Alarm System, (1)FACP and (93)Devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13901	15041-20000-23259	5262 N WILLOW CREST AVE	91601	2	171B177   363	2416028024	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.16669	-118.36201	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13902	14041-20000-27737	11846 W VENTURA BLVD SUITE 300	91604	2	162B169   259	2369027031	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.14238	-118.39054	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  WORK TO BE PERFORMED IN SUITE 300.  CHANGING LIGHTING FIXTURES AND ADDING POWER CONTROLLED OUTLETS TO OFFICES.  1312 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13903	17041-10000-11151	811 W WILSHIRE BLVD 17th Flr	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Issued	04/07/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	OFFICE TI. PC FOR T24 ENERGY ONLY, NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13904	12041-10000-16059	1248 S ELDEN AVE	90006	1	129B197  1002	5076017010	R3-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			07/11/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.04777	-118.28755	New fire alarm system for an existing apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13905	18041-10000-47839	5790 W JEFFERSON BLVD	90016	10	120B173   842	4205031012	[Q]M1-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	12/05/2023 12:00:00 AM	ADDRESS	34.02643	-118.37606	PLAN CHECK FOR TITLE 24 ONLY FOR EXTERIOR LIGHTING FOR GARAGE AND COMMON AREA OF BUILDING.  SCOPE INCLUDES GROUND LEVEL, LEVELS 2, 3, 16 AND 17 FOR AREAS NOT COVERED UNDER THE ORIGINAL PLAN CHECK FOR THE PROJECT.  - TOTAL AFFECTED AREA = 45862 SFORIGINAL PERMITED SET: 16041-10000-35204	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13906	18041-10000-05412	11525 N HUNNEWELL AVE	91342	7	213B165   684	2531015052	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.27887	-118.39572	Add rooftop PV system to Existing system (under permit# 13041-10000-00318, 5kW) for single story family dwelling. Install (12) AC modules, (1) solar subpanel	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13907	18041-10000-07454	15450 W VENTURA BLVD	91403	5	168B145   850	2283016040	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	34.15433	-118.47044	CHANGE RETAIL SPACE TO MEDICAL OFFICE; NO CHANGES TO LIGHTING SYSTEM; PERMIT 18041-20000-05957 WAS OBTAINED FOR NEW RECEPTACLESPLAN CHECK IS FOR POWER ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13908	16041-10000-01576	2029 S CENTURY PARK EAST SUITE S330	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM			PC Approved	01/15/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, PC FOR ENERGY. TI TO AN OFFICE TENANT IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES.  (approximately 2490 sq. ft.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13909	16041-10000-40118	2322 W 3RD ST	90057	1	135A203   200	5154035016	C2-1	Central	Westlake	MacArthur Park	YES	2088.02	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.06432	-118.27547	PC FOR T24 ENERGY ONLY. CONVERTING OFFICE TO EDUCATIONAL FACILITY. PROVIDED NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13910	19041-10000-03654	13520 W PAXTON ST A1	91331	7	210B157  1074	2535002015	M3-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.27356	-118.42606	PLAN CHECK FOR TITLE 24 ONLY TI TO RESTAURANT. TOTAL EFFECTED AREA 959 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13911	14041-20001-20997	8623 N RUDNICK AVE	91304	12	195B101   404	2004021029	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	34.22751	-118.61183	Fee for expedite only*****New roof mounted PV system, total system size 11.12KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13912	15041-20004-02760	6530 N SEPULVEDA BLVD	91411	6	180B145   491	2235002005	R1-1, R4-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			04/05/2018 12:00:00 AM			PC Approved	04/05/2018 12:00:00 AM	ADDRESS	34.18936	-118.46595	04-05-2018. Changes to an permitted set of plan. Changes include Service entrance conductor from Copper to Aluminum and from 2 Service entrance to 1 service entrance conductor, reconfigured meter bank in the electrical room single line diagram. Changes apply to delta E only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13913	16041-10000-35402	6399 W WILSHIRE BLVD	90048	5	135B173   818	5510028012	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.06391	-118.36796	Full Plan check. Converting an existing 11-story office building to hotel. Interior TI for entire building. New service rated at 1600A 480V 3Phase 4 Wire and all new equipment. Total sqft = 47291Build. located on methane zone bldg app # 16016-10000-23943	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13914	13041-10000-33210	1133 N VINE ST	90038	13	144B185   591	5533007023	[Q]C2-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.09171	-118.32698	PLAN CHECK FOR POWER AND ENERGY.DESCRIPTION FROM BUILDIN DEPARTMENT: 5 STORY, 112 ROOM HOTEL WITH 1 LEVEL OF UNDERGROUND PARKING (TYPE I-A GARAGE & TYPE V-A RESIDENTIAL ABOVE)  SEE COMMENTS...	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13915	18041-20000-30701	17893 W RIDGEWAY ROAD	91344	12	216B129   336	2601032037	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.28515	-118.5242	PV1.  Install 7.50 kW DC/6.53 kW AC-CEC ground mounted grid tied PV system.  (25) modules with 6 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13916	10041-20001-07018	5724 W HOLLYWOOD BLVD	90028	13	148-5A191 154	5586035041	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM			PC Approved	04/28/2010 12:00:00 AM	ADDRESS	34.10155	-118.31451	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT.  EXISTING PERMIT ON ELECTRICAL SWITCHES - OUTLETS AND LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13917	13041-10001-32630	5106 N MATILIJA AVE	91423	4	171B153   595	2269003003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.16343	-118.43332	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY. TRANSFORMERLESS UNGROUNDED SYSTEM. SYSTEM SIZE:4KW DC. 1 STORY.(16) RENESOLA SOLAR MODULES JC 250M(16) POWER OPTOMIZERS(1) SOLAREDGE SE3800	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13918	18041-10000-40388	1150 S OLIVE ST 1200	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.03962	-118.26181	PLAN CHECK FOR ENERYGY ONLY TO AN INTERIOR OFFICE T.I. NO CHANGE OF USE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 9510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13919	14041-20000-17572	12154 W MONTAGUE ST	91331	7	204B165    89	2537018027	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.25712	-118.39806	Site and building exterior lighting.  Plan check for Title 24 for changes to lighting system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13920	15041-10000-10445	1859 N HILLHURST AVE	90027	4	150B197   941	5590016026	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.10486	-118.28757	PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO CITI BANK. TOTAL AREA 3883 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13921	13041-20000-01089	11350 W SHELDON ST PV-1	91352	7	201B173   117	2538023006	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.25051	-118.37823	PV-1. 12.936kW. Taron Residence	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13922	18041-20000-23488	6442 N BOBBYBOYAR AVE	91307	12	180B093   760	2036008017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Expired	04/26/2024 12:00:00 AM	ADDRESS	34.18761	-118.63238	Plan check for PV roof mounted system, system size: 15.2kW with 42 modules and 2 inverters(7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13923	12041-10000-18791	2801 S CRENSHAW BLVD	90016	10	123B185   951	5050017023	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Info Complete	08/09/2012 12:00:00 AM	ADDRESS	34.03093	-118.33534	"TI IN AN EXISTING ""EL POLLO LOCO"". PLAN CHECK FOR T-24 ENERGY CALCS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13924	18041-10000-03056	19059 W VENTURA BLVD	91356	3	174B121   385	2163020900	C2-1VLD, RA-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.17271	-118.5493	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13925	18041-10000-01970	3116 W AVENUE 32	90065	13	154-5A213 177	5458012011	CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM			Reviewed by Supervisor	03/22/2018 12:00:00 AM	ADDRESS	34.11683	-118.24348	PC FOR POWER AND ENERGY FOR CHANGE OF USE FROM EXIST MANUFACTORY TO OFFICE AND WAREHOUSE.TOTAL CONNECTED LOAD >400ATOTAL AFFECTED AREA 35875 SQ. FT.SCOPE INCLDES NEW AND RELOCATED PANELS, NEW EQUIPMENT, CIRCUITS AND LIGHTS. B# 17016-10000-31496	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13926	17041-20000-11436	400 N BRISTOL AVE	90049	11	135B137   617	4405017010	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.06274	-118.48842	PLANCHECK FOR A NEW SINGLE FAMILY DWELLING. 600 AMP SERVICE. PLANCHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13927	16041-20000-37491	815 N PASEO MIRAMAR	90272	11	129B117    33	4416022047	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.04931	-118.55762	PLANCHECK FOR POWER. NEW SINGLE FAMILY RESIDENCE. 600AMP 120/240V SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13928	19041-20000-23903	1394 W SUMMERLAND AVE	90732	15	018B193   158	7446004029	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	33.74709	-118.30621	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.54 KW DC/10.6KW AC. SCOPE OF WORK INCLUDES (38) PANASONIC PV MODULES WITH P400 OPIMIZIERS AND A SE7600A-US INVERTER AND A SE3000H-US AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13929	16041-10000-03629	6220 W 87TH ST	90045	11	096B165   763	4123002016	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM			PC Info Complete	04/04/2016 12:00:00 AM	PIN	33.95834099	-118.39415614	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. CHANGE OF USE FROM RETAIL TO NEW RESTAURANT SPACE. TOTAL AFFECTED AREA IS 812 SQ. FT.NOTE: PERMIT PULLED UNDER PCIS#15041-10000-27069	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13930	11041-10000-14913	2503 W 7TH ST	90057	1	133-5A201 232	5141007014	C2-2	Central	Westlake	MacArthur Park		2088.00	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	07/18/2011 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	ADDRESS	34.05883	-118.28161	New fire alarm with one panel, one power module, and 110 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13931	16041-20000-39355	11601 W WILSHIRE BLVD Suite 1110	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM			PC Approved	11/07/2016 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for energy only. TI to office suite 1110 in existing high rise building. New lighting (incl. emergency) and receptacles. 1,849sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13932	10041-20000-07007	8401 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	04/16/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.22253	-118.62558	energy plan check testing lab	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13933	18041-20000-43592	5020 N WOODMAN AVE	91423	4	171B157   953	2359024031	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			11/14/2018 12:00:00 AM	01/13/2020 12:00:00 AM		Permit Finaled	10/10/2023 12:00:00 AM	ADDRESS	34.16201	-118.43103	Power and lighting for new apartment building.  3000A 208Y/120V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13934	18041-20000-05921	315 S JUNE ST	90020	4	135B185   127	5507001013	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.06832	-118.33435	Plan check for a PV1 roof-mounted PV system. System size is 15.1 kWac and consists of (42) AC PV modules and (2) load centers.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13935	13041-10000-10690	20251 W VENTURA BLVD #251D	91367	3	174B113   515	2166033040	(Q)C4-1LD, (Q)P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	PIN	34.16986681	-118.57545146	PLAN CHECK POWER AND ENERGY FOR MEDICAL OFFICE (MRI CENTER) SUITE #251D. INCLUDES XRAY AND MRI MACHINE. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13936	14041-10001-03659	833 E 3RD ST	90012	14	129A215   259	5163007010	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	PIN	34.04615917	-118.23530019	(9/23/2015)CHANGES TO AN APPROVED SET OF PLANS.  PLAN CHECK FOR POWER ONLY.  NEW (2) SERVICES MSA AND MSB RECONNECTING TO EXISTING LOADS, NO NEW ADDED LOADS.Plan check for power and energy. core and shell  improvement for a commercial. Existing building. New service with 1600A, 227/480V, 3PH, 4WIRE undergrounded . Projected area in lighting work is approx. 5804 SQ FT ( 2204 indoor, 3600 outdoor) . 6 section with bus rating 1600 A.sERVICE LOAD SHOWS THE HOUSE METER AND THE REST IS FUTURE. fUTURE TENANATS NEED SEPERARTE PLAN CHECK APPROVAL.  THIS PLAN CHECK IS FOR CORE AND SHELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13937	19041-10000-53148	6600 N TOPANGA CANYON BLVD SUITE-#1084D	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	02/21/2020 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	ENERGY PLAN CHECK ONLY. TAILOR METHOD IS USED.TI, AREA OF SCOPE 2917SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13938	16041-10000-28680	13439 W BURBANK BLVD	91401	2	174B157   540	2343015018	(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			08/12/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.17234	-118.42584	Plan check PV2 roof mounted system. System size: 21kW with 3 inverters(SMA SB7000TL-US-208)  and 60 modules(CS6X-320)  connected to House panel of the appartement building.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13939	18041-30000-30689	2506 S LINCOLN BLVD	90291	11	108B149   781	4236030024	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	33.99231	-118.44908	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR VCA  ANIMAL HOSPITAL. 400 SQFTBUILDING PERMIT # 18016-30000-21815	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13940	17041-10001-16628	10250 W SANTA MONICA BLVD # 1935	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	1st revision to approved set noted under delta 2. Scope: Relocate few branch ckt, recalculate load on panels. Revise wattage and voltage class on few fixtures, revise T24 calculation for -Aesop- at Century City Mall Space 1935. This is plan check only, permit is covered under master #17041-10000-16628	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13941	11041-10001-11566	681 S BONNIE BRAE ST	90057	1	132A203   154	5142002904	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.05601	-118.2743	NEW STAND-ALONE FIRE ALARM SYSTEM IN EXISTING 6-STORY MIXED USE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13942	11041-10005-10748	1900 S SEPULVEDA BLVD	90025	5	126B153   181	4323022031	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.04447	-118.4413	Plan check for revision to Fire Alarm System approved plans.  Additional devices and power supply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13943	16041-20000-36461	12628 N AMBOY AVE	91342	7	219B145    37	2604015021	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Expired	04/07/2024 12:00:00 AM	ADDRESS	34.30082	-118.47175	PV1.  Install 14.620 kW AC roof mounted PV system.  (43) modules with (1) 11.4 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13944	18041-20002-05802	20141 W WELLS DR	91364	3	171B113   458	2166009006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2018 12:00:00 AM			PC Approved	07/03/2018 12:00:00 AM	ADDRESS	34.16189	-118.57156	Changes to an approved set of plan, Changes include module layout Changes. Plan check only. Fees $0 permit fee per State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13945	12041-20000-17944	12422 W BLUFF CREEK DR Bldg  1	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	33.97704	-118.40702	Core and shell for building 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13946	14041-10000-35327	18640 W VENTURA BLVD	91356	3	174B121   791	2161015001	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.17013	-118.54006	Energy plan check for a retail (ATT) store T.I .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13947	13041-20000-20550	2701 N GLENDOWER AVE	90027	4	153B197   104	5588020030	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.11628	-118.29464	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 8.42 KW. 36 MODULES AND 2 INVERTERS. 400A EXISTING SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13948	10041-10000-21847	1943 S PELHAM AVE	90025	5	129B157   659	4321008011	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Public Safety Only			11/02/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.04968	-118.43021	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING FOR A 3-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13949	18041-10000-39713	9400 N MASON AVE	91311	12	198B109    68	2748022048	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.2413	-118.57962	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13950	18041-20000-29364	12128 W VENTURA BLVD	91604	2	162B165   169	2369014005	C2-1VL-RIO, R4-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM			Corrections Issued	08/03/2018 12:00:00 AM	ADDRESS	34.14334	-118.39618	New lighting for (E) commercial retail space.  Plan check for energy - 700 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13951	12041-10000-26293	9600 W PICO BLVD	90035	5	132A167   258	4306001037	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.05501	-118.39777	T24 TI EXISTING RETAIL. 2024 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13952	15041-20001-43125	9055 N TELFAIR AVE	91352	6	195B165    94	2631005029	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.23385	-118.39436	02/19/2016 Supplemental plan check for the deration of the main service panel breaker. Service load calculations have been included.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13953	19041-10000-26361	18442 W SHERMAN WAY	91335	3	183B125   193	2125001023	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.20095	-118.53507	Replace fluorescent troffers with new led retrofit kits- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13954	17041-20001-18040	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2017 12:00:00 AM			Reviewed by Supervisor	06/07/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD and detached garage.8.88kW ungrounded system.(37) EnPhase M250 microinverters.(37) 290W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13955	19041-20000-21353	20700 W SESNON BLVD #173	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR NEW 2-STORY SFD. SYSTEM SIZE 5.025KW DC/4.8KW AC. SCOPE OF WORK INCLUDES (15) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13956	19041-10001-32715	3690 E NOAKES ST	90023	14	117A227    90	5192017006	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM			PC Approved	01/14/2020 12:00:00 AM	ADDRESS	34.01407	-118.19672	RESUBMIT FOR PLAN CHECK DUE TO LOST MARKED UP SET. ORIGINAL CORRECTION LIST ATTACHED. POWER AND ENERGY PLAN CHECK FOR CHANGE OF USE AND TENANT IMPROVEMENT. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 11,400 SQ.FTB# 19016-10000-26124	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13957	18041-20000-22246	5511 W THORNBURN ST	90045	11	102B173   437	4103009098	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Apartment			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	33.97271	-118.3762	Plan check for new Fire alarm system for 3 story 34 units apartment building. Total Fire alarm devices: 146  and 1 FACP. B#17010-30000-01705	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13958	12041-10000-26377	4371 S GLENCOE AVE	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	33.9857	-118.43834	"TI IN AN EXISTING COMMERCIAL AREA.  BILDING A NEW WALL TO SPILT THE SPACE INTO TWO  SPACES ""B9A"" AND ""B9B"".  PLAN CHECK FOR T-24 ENERGY CALCS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13959	10041-20000-13120	6033 W CENTURY BLVD #900	90045	11	090B169    17	4124030037	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM			PC Approved	07/09/2010 12:00:00 AM	ADDRESS	33.94572	-118.38954	T.I. to existing high rise building(9th floor, room 991 - 9910).  Relocate general and emergency fixtures.  Plan check for energy only.  Permit under 10041-90000-11576.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13960	15041-20001-23703	15800 W STRATHERN ST Bldg. 3	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.21559	-118.47752	8.15.2016 - Plan check for modifications to approved set (delta-6 revisions). Revision of plan for building 3. New/revised lighting, equipment, and circuits. Recheck power and energy. Some (E) equipment wasn't shown on originally approved plan, plan has been revised to reflect field conditions (for example T2).APPROVAL FOR DELTA-6 AS-BUILT CHANGES ONLY.  =====Plan check for power and energy.  Total area = 1,035 sq. ft. (indoor) + 400 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13961	18041-10000-19519	13921 S FIGUEROA ST	90061	15	075B201    14	6132006025	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.90524	-118.28293	REPLACE INDOOR/OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
13962	19041-10000-32122	3316 S MAIN ST	90007	9	118-5A205 194	5120003009	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	01/09/2024 12:00:00 AM	ADDRESS	34.01899	-118.27219	PC for T24 only, scope of work is a TI in a existing building on the second and third floor. Scope of work includes new lighting, controls, and circuits. Total affected area is 30468 sqft. B#19016-20000-15061	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13963	18041-20001-04788	13155 W HARTSOOK ST	91423	4	171B157   686	2358001002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	34.16408	-118.41994	01/16/2019 Changes to an approved set. Electrical equipment has been relocated. AC disconnect for battery back-up unit is no longer fused.*****Previous Work Description*****install (1) tesla powerwall to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13964	16041-20000-16883	11539 N BABBITT AVE	91344	12	213B133   520	2607007033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.28063	-118.50834	Plan check for PV roof mounted system. System size: 6.0kW with 29 modules and 1 inverter 6.0kW. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13965	16041-20000-15487	970 W 190TH ST Ste 990	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	33.85812	-118.29302	Existing commercial office remodel in commercial highrise building.  All new lights, all existing circuits.  Plan check for energy - 2002 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13966	13041-10001-26316	5950 N VANALDEN AVE	91356	3	177B121   694	2156009001	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.17857	-118.54982	][][]EXPEDITED PER APPLICANT REQUEST ][][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON STANDARD PLAN WITH POWER OPTIMIZERS(OP250-LV).; SYSTEM SIZE IS 4.25KW DC WITH (17) MODULES: TRINA #TSM-250PA05.18(1) SOLAREDGE #SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13967	19041-10000-13411	1045 S BROXTON AVE	90024	5	132B149    52	4363024007	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.06163	-118.44658	PC POWER AND T-24 FOR TI(THEATER). EXISTING (2) 400A SERVICE - 120/240V (1PH/3PH) AREA SCOPE 5,341SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13968	10041-10000-07665	11611 W SAN VICENTE BLVD SUITE 900	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.0541	-118.46261	NEW LUMINAIRES IN OFFICE SPACE   ; PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13969	14041-20000-12019	12650 W SANDHILL LANE Unit 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.9774	-118.4142	Roof mounted PV system with system size 1.38KW.  Using transformerless inverters.  This part of a series set of submittal.  This PV system to interconnect to common service.  This is project 3 of 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13970	16041-10002-44009	10250 W SANTA MONICA BLVD # 1580	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set noted under Delta-6:(1) Replace the Main Circuit Breaker of Panel H 277/480V from 200A to 100A(2) Add 2 circuits on panel L and increase the Insta-Hot water heater load(3) Revise the load calculation of panel L	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13971	16041-20000-23858	3641 S MOTOR AVE	90034	5	120B161   903	4314008012	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM			Reviewed by Supervisor	07/22/2016 12:00:00 AM	ADDRESS	34.02382	-118.40673	PLANCHECK FOR POWER AND ENERGY FOR A 12 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13972	17041-10000-19265	1660 W ANAHEIM ST	90710	15	033B193   373	7411008034	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	33.78627	-118.30659	Install a new 100A DPB to supply power to 3 new 1HP pumps as well as a new NRTL Listed 15kVA transformer and mini power center.  Plan check for power.  Hazardous classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13973	18041-10001-16909	500 S VIRGIL AVE #101	90020	13	135A201    62	5077005030	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.06492	-118.28687	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REMOVAL OF EXISTING LOADS AND RELOCATION OF PANEL A. CHANGES ARE CLOUDED UNDER DELTA 1ORIGINAL PERMIT TI IN AN EXISTING MEDICAL OFFICE BUILDING (OSHPD 3) IN SUITE #101 ON THE 1ST FLOOR.  PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT # 18016-10000-10313	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13974	16041-20001-45017	1451 E 4TH ST	90033	14	127-5A219 339	5172020019	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	ADDRESS	34.04249	-118.22532	7/17/17changes to an approved set of plans. changes include recalculation of energy compliance forms and additional circuits to reflect field conditions noted delta 1.    (((Commercial office TI in (E) 2-story commercial building.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13975	11041-10001-25644	10227 N MASON AVE 1-50	91311	12	204B109   215	2741025038	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Apartment			05/31/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.25626	-118.58016	change of feeders from CU to AL, re feeding exit signs from normal and use unit equipment,  rain proof is nema 3R.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13976	09041-10001-22122	6639 N LAUREL CANYON BLVD	91606	2	180B165   299	2322004071	C2-1L, P-1, P-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1233.01	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.19147	-118.39671	Plan check for Delta 4 revision only. Includes outdoor lighting T-24 and changes to electrical room layouts.  Permit is for additional circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13977	14041-20000-04092	10400 N GLADE AVE	91311	12	204B101    59	2723019105	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.25925	-118.60809	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (N) UPGRADED MAIN SERVICE PANEL. UNGROUNDED SYSTEM, SIZED @ 4.5 kW DC, WITH (18) YINGLY YL250P MODULES, , (1) POWER-ONE-PVI-3.6-OUTD-US-A INVERTER WITH AFCI.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13978	13041-10001-15109	20307 W WYNFREED LANE	91326	12	216B113   267	2701048054	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.2918	-118.57551	changes to approved set of plans: changed to yingli YL245P-29B. downgraded solaredge 3800 inverter to 3000. downsized breaker from 175 to 150A.PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 10.05 KW, 41 TOTAL MODULES WITH POWER OPTIMIZERS. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTERS: SOLAREDGE # SE3800A-US AND SOLAREDGE # SE6000A-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13979	19041-10002-32003	9201 N OWENSMOUTH AVE	91311	12	198B105   144	2746012037	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM			PC Approved	09/27/2019 12:00:00 AM	ADDRESS	34.23757	-118.60203	THIS IS A PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 1. SCOPE OF WORK INCLUDES CHANGING THE LAYOUT OF THE ROOFTOP MODULES. PERMIT TO BE PULLED UNDER MASTER APPLICATION 19041-10000-32003.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13980	13041-10004-34279	21720 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Expired	08/08/2017 12:00:00 AM	ADDRESS	34.18733	-118.60234	DELTA 65 AND DELTA 65A CHANGES: NEW 2000A SWBD FOR EXISTING OFFICE BUILDING; REPLACE 6 EA PANEL BOARDS; DEFINE SECONDARY FEEDERS OF TRANSFORMERS OF MV UNIT SUBSTATIONS SUPPLYING NEW BUILDINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13981	15041-20000-31265	4929 N AUCKLAND AVE	91601	4	168B177   152	2420001007	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.1603	-118.36049	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13982	13041-20000-04690	7054 N VANSCOY AVE	91605	2	183B161   269	2324032013	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.19911	-118.40616	New fire alarm for an existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13983	13041-10001-26504	24917 N BAYPOINT AVE	90744	15	039B209   293	7404026019	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	33.79972	-118.26022	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE: 8.25 KW.(33) RENESOLA SOLAR MODULES(2) SOLAR EDGE SB3800A INVERTERUPGRADE TO 200 AMP PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13984	17041-10000-30268	22815 S FRAMPTON AVE	90501	15	045B197    50	7347018031	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	33.81849	-118.2997	T-24, PC FOR ENERGY ONLY. REPLACING OUTDOOR LUMINAIRES WITH LED TYPE. TOTAL AFFECTED AREA IS 20000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13985	15041-20003-37727	18209 W PARTHENIA ST	91325	12	195B125   794	2769019041	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.2289	-118.52978	(1/3/2017)changes to an approved set of plans.  providing pv breaker and AC disconnect.  changes clouded.this is plan check only.    Revisions to approved set of plans.  Reduction in system size to (240) modules, change to # of inverters to (1) Growatt 20000TL3-US and (1) Growatt 36000TL3-US inverters, and multiple changes to conductor routing details and equipment layout.  Project is now properly identified as Feed-in-Tariff project per LADWP service letter.  Inverter voltage class output changed to 480V 3ph, connected to 240V 3ph service meter through isolating transformer. THIS IS PLAN CHECK ONLY. (((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERICAL ROOF-TOP. TOTAL SYSTEM SIZE IS 79.12KWdc/80.0KWac. (344) MODULES-SCHUCO MPE-230W (4) INVERTERS-GROWATT 20,000-UE (240V)(1) 200A SUBPANELNOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13986	12041-20001-24229	424 N ARDEN BLVD	90004	4	138B189    79	5523019005	R1-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2013 12:00:00 AM			PC Approved	01/17/2013 12:00:00 AM	ADDRESS	34.07818	-118.32585	Slight modification to approved plans to relocated 2 panels.  No change in the equipment or wiring.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13987	16041-10000-06798	10740 W STRATHERN ST	91352	2	189B177   968	2409007035	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	PIN	34.2154559	-118.36552892	PV 1 roof mounted solar system installation to a single family home. Central Inverter rating : 3.8 kw, (13) modules.(13)Modules-Sunpower SPR-327NE-WHT-D(1)Inverter-Power One PV-3.8-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13988	17041-10000-14481	1016 W E ST BLDG 9	90744	15	030B201   836	7417012924	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM				Plan check for  new residemtial building - fire alarm plan project consist of 1 fire alarm panel, and 41 devices. Note:PERMIT FOR BUILDING # 9 , LOT 3.  16041-20000-05212.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13989	13041-20000-31349	8138 N WOODLAKE AVE	91304	12	189B093    13	2014024002	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.21768	-118.63204	T24 FOR EXISTING RETIREMENT HOME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13990	17041-10000-35848	8500 W BEVERLY BLVD 119	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC for power and energy for first time tenant for lounge area.  Total area is 5056 sqft.Installing two new panels, new circuits, lights. B# 17016-10000-35848	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13991	15041-20000-33696	9623 N DONNA AVE	91324	12	201B121   584	2762033024	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.24546	-118.54767	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.  THIS PV SYSTEM IS IN ADDITION TO THE EXISTING PV SYSTEM.(13) TRINA SOLAR MODULES TSM-255(1) ABB 3KW INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
13992	19041-20000-26121	4930 N LAUREL CANYON BLVD	91607	2	168B165   114	2355009076	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	05/11/2021 12:00:00 AM	ADDRESS	34.16022	-118.39629	New 3-story 8-unit apartment building.  800A 240/120V 3ph-4w overhead service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13993	13041-10000-35124	"1849 E 45TH ST BLDG ""B"""	90058	9	112-5A215  40	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.0029	-118.24014	T24 PART 6 ENERGY FOR (E) 16,375 SQ FT COMMERCIAL SPACE. RETRO-FITTING 4' FLUORESCENT LIGHT FIXTURES. SCOPE OF WORK < 400A. PERMIT IS EXISTING. NO NEW/MOVED WIRING, LIGHTING PANEL INSTALLED/RELOCATED PER APPLICANT. SUBJECTED TO FIELD VERIFICATION IF SECTION 131 OF ENERGY CODE NEEDS TO BE COMPLIED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13994	18041-20000-35815	12001 W OCEAN PARK BLVD NO 1	90064	11	120B149   434	4257001***	RD1.5-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.02504	-118.44583	Plan check for PV roof mounted system, system size: 5.547kW with 18 modules and 1 inverter(5.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13995	16041-20000-18380	12429 W VENTURA BLVD	91604	2	162B165   208	2367018026	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.14295	-118.40409	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from retail to gym. Total lighting area = 2,424 sq. ft.Note: Building permit has been pulled under 15016-20000-16366	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
13996	17041-10000-44425	9070 N VENA AVE	91331	6	195B161   183	2628015011	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.23409	-118.41232	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.50KWdc / 3.80KWac.(15)MODULES-HANWHA Q CELL Q.PEAK-G4.1 300(15)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13997	19041-10000-11101	20200 W SEPTO ST	91311	12	201B113   116	2741017019	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.25077	-118.57342	NEW 5.49KW ROOF MOUNTED PV SYSTEM WITH 18 PV PANELS ON THE ROOF OF A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
13998	18041-20001-12302	20434 W ARBELLA PL	91326	12	216B109   218	2701082032	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.29249	-118.57931	Expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
13999	17041-10002-18217	16925 W DORMIE PL	91436	5	168B133   451	2289016039	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM			PC Approved	08/17/2017 12:00:00 AM	ADDRESS	34.15405	-118.50213	pc for revisions to reflect field installation. scope includes location revision to roofplan and location of equipment. plan check only!Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system.  Total system size = 16.2 kWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14000	19041-20000-26607	5012 N MAMMOTH AVE	91423	4	171B157  1013	2269002020	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.16154	-118.43229	Installation of 13.5 kWh energy storage.  (E) PV and 13.5 kWh energy storage system on site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14001	15041-20000-39772	5800 W SUNSET BLVD PHASE 1B	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENTS FOR TV STUDIOS AND ASSOCIATED SUPPORT SPACES..  PHASE 3 of 5 PHASE PROJECT FOR STAGE 6 AND BUILDINGS 16. STAGE 6- [[[ FEES BASED ON APPLICANT- PLANCHECKER TO REVERIFIY]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14002	15041-20000-16302	936 S OLIVE ST UNIT 354	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #11 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14003	14041-10000-15911	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	T24 FOR EXISTING RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14004	16041-10000-40317	10120 N CANOGA AVE	91311	12	204B105   577	2747009086	(Q)CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.25426	-118.59713	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures for indoor and outdoor. Total affected area is 15080 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14005	13041-10001-25449	380 WORLD WAY	90045	11, 8	120B197   706	5040021020	LAX, RD2-1	South Los Angeles, West Los Angeles	Los Angeles International Airport, South Los Angeles, Westchester - Playa del Rey	Empowerment Congress North Area, Westchester - Playa del Rey		2226.00, 9800.28	Electrical	Electrical	Apartment			09/16/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Install 12 lights	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14006	17041-20000-06492	1540 W FRANCISCO ST	90501	15	057B193    29	7351021033	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	33.84927	-118.30492	Plan check for installation of solar PV system, roof-mounted on commercial building.LADWP Feed-in-Tariff project ~ new 1600A switchboard.960 kW ungrounded system [12 - 80kW inverters]. (4104) 340W PV modules.$0 permit fee is due to State Senate Bill SB-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14007	18041-20000-47833	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	33.98722	-118.47211	Plan check for Title 24 only Tenant Improvement expand existing restaurant/kitchen. Total area: 150  sq ft. B#18016-10000-30017	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14008	19041-20000-43680	3701 W 61ST ST	90043	8	105B185   511	4004031034	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	33.98456	-118.33795	Plan check for PV roof mounted system, PV system size; 5.78KW wih 17 PV Modules and 1 inverter(6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14009	19041-20000-08754	213 S SPRING ST basement	90012	14	130-5A213  77	5149008029	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.05103	-118.24646	replace of existing emergency equipment 1 for 1 to an existing  high rise building.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14010	13041-10000-30275	975 S WESTCHESTER PL	90019	4	129B189   104	5092020016	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Info Complete	10/29/2013 12:00:00 AM	ADDRESS	34.05325	-118.31618	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH EXISTING 200A SERVICE. SYSTEM SIZE IS 6.0KW DC, WITH 24 MODULES(HANWA HSL 60-250W), 24 ENPHASE MICROINVERTER (M215-60-240). 3 STRINGS; NEW 30A RATED SUBPANEL WILL BE INSTALLED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14011	12041-20000-07832	15821 W VENTURA BLVD # 185 and-# 195	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.15584	-118.47812	Tenant work, remodel of bank. Plan check for energy and emergency power. Commercial high-rise building. 6,165 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14012	15041-10000-03972	1905 S VICTORIA AVE	90016	10	126B185  1016	5061001001	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.03949	-118.33289	Plan check for PV 1 roof mounted, 3.8kW with 17 modules and 1 inverter(3.8kw)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14013	17041-20000-35692	2731 N EDWIN PL	90046	4	156B169   284	5564001019	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.12249	-118.38859	pv1install roof mounted pv system sized 7.6kw with tesla powerwall interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14014	16041-10000-44665	3720 N BARHAM BLVD (BUILDING-A)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.14119	-118.34152	"PC FOR POWER, SCOPE OF WORK INCLUDES NEW (27) UNIT PANELS, NEW ""STACKED"" WASHER & DRYER CIRCUITS, AND NEW MICROWAVE CIRCUITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14015	12041-10001-28949	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	33.78734	-118.29768	permit to be pulled at EPC counter only. (CHANGE TO APPROVE PLANS. luminaire type change from T5 TO T8. T24 UPDATED)PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN A PHARMACY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14016	17041-10000-39307	962 E 41ST PL	90011	9	114A209    27	5115022016	R2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.00823	-118.25874	PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE  3.8KWAC / 4.4KWDCSCOPE INCLUDES 16 MODULES WITH OPTIMIZERS AND  SINGLE INVERTER .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14017	13041-20000-02713	6104 N SEPULVEDA BLVD	91411	6	177B145   597	2242025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.18078	-118.46593	Full plan check for Ti. Staples. Plan check fees per applicant.  Site is in a Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14018	15041-10000-01821	818 W 7TH ST ste 880	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Expired	02/15/2017 12:00:00 AM	ADDRESS	34.04895	-118.25943	Energy plan check for an office T.I in a high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14019	11041-20000-19403	9731 N VESPER AVE	91402	7	201B149   429	2650020017	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Apartment			09/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.24694	-118.4506	Plan check for new 2-story, 11-Unit Apartment building with 800A service. Site on Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14020	18041-10000-14535	2580 N GLENDALE BLVD	90039	4	150A209   185	5438016002	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.10497	-118.25927	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14021	14041-10000-04677	610 N VAN NESS AVE	90004	4	141B189   605	5522005001	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.08196	-118.31559	PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(10) MODULES:  TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14022	10041-20000-23300	12330-12332 W VENTURA BLVD	91604	2	162B165   258	2369002023	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.14281	-118.40186	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14023	10041-20000-09854	461 S BOYLSTON ST maryland	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.05463	-118.25943	CHILLER ADDITION AT MARYLAND STREET BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14024	16041-10000-02870	2416 E 8TH ST	90021	14	123A217   318	5166007010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.02943	-118.22921	PC for energy only to an existing single story building (studio). Total sq ft = 10863	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14025	13041-10002-05687	333 S FIGUEROA ST 1ST FLOOR	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.05436	-118.25543	[][][]TITLE-24 EXPRESS PERMIT TO BE PULLED ][][(((((   title 24 only   medi 70-22-14T24 FOR RENOVATION OF EXISTING RESTAURANT AND LOBBY AREA OF EXISTING HIGH RISE HOTEL (FIRST FLOOR). 9080 SQRFT AND 11,880. PLAN CHECK UNDER ONE APPLICATION NUMBER HOWEVER THE PERMIT WILL BE PULLED IN 2 SEPERATE PHASES. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14026	19041-10000-26840	3170 W OLYMPIC BLVD	90006	10	129B193   408	5080017014	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Apartment			07/12/2019 12:00:00 AM	08/03/2020 12:00:00 AM		Permit Finaled	04/10/2023 12:00:00 AM	ADDRESS	34.05236	-118.3054	NEW 5 STORY, MIXED USE, 252 UNIT APARTMENT BUILDING OVER GRADE LEVEL PARKING GARAGE/RETAIL AND SUBTERRANEAN GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14027	19041-10000-22503	4383 N TUJUNGA AVE	91604	2	165B173   400	2365015028	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.14973	-118.37914	pc for energy only for existing resturant. area of scope 1,261sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14028	19041-10000-45244	4305 N CLEAR VALLEY DR	91436	5	165B137   238	2284018027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	05/02/2020 12:00:00 AM	ADDRESS	34.14913	-118.48564	FEES ARE $0 DUE TO AB1414(E-PLAN) UPDATE: CHANGES TO AN APPROVED SET OF PLANS FOR  RELOCATION  OF ROOF LAYOUT. CHANGES HAVE BEEN CLOUDED UNDER DELTA (A). ALL NUMBER OF MODULES, OPTIMIZERS, AND INVERTER REMAINS THE SAME.NOTE: PERMIT FEES HAS BEEN PAID UNDER THE MASTER APPLICATION: 19041-10000-31451	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14029	18041-30001-22187	801 S BERENDO ST	90005	10	132B197   464	5094014001	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Apartment			08/21/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	34.05753	-118.29435	PLAN CHECK FOR A LOST SET OF PLANS, PERMIT PULLED UNDER MASTER APPLICATION. Fire alarm plan check for a fire alarm system in a 7-story 98-unit apartment building. Scope includes (1) fire alarm panel, (4) power supplies, and (287) fire alarm devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14030	17041-20000-16132	900 W WILSHIRE BLVD 11th floor	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	Interior TI to 11th floor for commercial office space.  Plan check for energy.  Building permit filed under 17016-10000-11611.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14031	14041-10000-30011	1740 1/2 W 62ND ST	90047	8	105B193   825	6002029017	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.98314	-118.30812	PV2 ROOF MONTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL.  SYSTEM SIZE 3 KW WITH 12 MODULES WITH 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14032	14041-20000-20489	8423 W FOOTHILL BLVD	91040	7	207B189  1102	2555025012	C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.25986	-118.31655	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14033	09041-10001-17054	849 E NEW DOCK ST Berths-212-216	90731										Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM			PC Approved	02/24/2011 12:00:00 AM	ADDRESS	33.75812	-118.24877	REVISED AMP BOX 2 LOCATION AND REVISED CONTROL WIRE; SINGLE LINE DIAGRAM REVISED TO THE NEW LENGTH OF THE FEEDERS SUPPLYING AMP BOX 2 ; REVISED ASSOCIATED CONTROL WIRES)))))))))))))PLAN CHECK FOR POWER.  AMP RETROFIT FOR PORT OF LOS ANGELES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14034	11041-10000-22455	3900 N STANSBURY AVE	91423	5	162B153   353	2274027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.14084	-118.44264	Fire alarm for a private school.  77 new fire alarm devices to be installed and one new panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14035	16041-10002-11963	10250 W SANTA MONICA BLVD STE 195	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Info Complete	03/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set noted under Delta-9 and 14:(1)Add three lighting control panels 50A each.   (2)Remove and add some circuits.   (3)Update load calculation.   (4)Revise lighting fixtures, photometric, & T24.   (5)Update lighting and power floor plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14036	17041-10000-37831	9001 N TAMPA AVE	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.23383	-118.55386	TITLE 24 ONLY, RELACE OUTDOOR EXISTNG FIXURES WITH LED FIXURES, TOTAL SQUARE FOOTAGE 17900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14037	13041-10000-11563	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Closed	06/17/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	AS PART OF THE COLUMBIA SQUARE REDEVELOPMENT, TWO BUILDINGS SHARING A CONNECTING CANOPY WILL HAVE THE CANOPY REMOVED. A BUILDING PERMIT WAS ISSUED FOR  EACH BUILDING-6125 W SUNSET BLVD HAVING 6 FLS AND 6121 W SUNSET BLVD HAVING THREE FLOORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14038	13041-20000-00731	10141 N RESEDA BLVD	91324	12	204B125   654	2729011008	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			01/10/2013 12:00:00 AM	01/10/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.25518	-118.53637	energy plan check retail space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14039	19041-20000-49366	13600 W VENTURA BLVD	91423	4	165B157   728	2373013001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Issued	12/09/2019 12:00:00 AM	ADDRESS	34.14752	-118.4296	New lighting for (E) 2-story commercial buiding.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14040	16041-10001-27511	15239 W LA CRUZ DR	90272	11	129B125   795	4412002017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.04564	-118.52549	08-26-16 Changes to an approved set of plans. Changes include replace 2cx2 lighting fixtures to 6 in x 48in and add lighting fixture to the closet and unit equipment in storatge space and add a unit equipment on roof. Changes has been cloud. {{{{{{Plan check for T-24 only. TI to an (E) classrooms at Seven Arrows Elementary, total affected area: 3,804 sq.ft}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14041	10041-10000-23505	201 W WORLD WAY 201A	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Closed	05/17/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY  ( 2-DAYS ) STANDBY GENERATOR  TO SUPPLY POWER TO EACH OF TWO MCC WHICH POWERS EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14042	12041-10000-09803	18910 W RINGLING ST	91356	3	171B121   534	2176011010	RA-1	South Valley	Encino - Tarzana	Tarzana		1398.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.1618	-118.54481	installation of a 8.925KW photovoltaic system with microinverters on the roof of a SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14043	14041-10000-04678	12881 W FILMORE ST	91331	7	213B161   874	2533028034	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.27768	-118.41374	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14044	17041-10002-17754	737 W 30TH ST ROOF	90007	9	121-5A201 161	5123013006	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.02641	-118.28077	OFF HOUR PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14045	13041-10001-12841	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Info Complete	10/25/2013 12:00:00 AM	ADDRESS	34.15777	-118.43065	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. DELTA 1. ADDING 75KVA TRANSFORMER AND SEWAGE LIFT PUMPS.  REMOVE RECEPTACLES IN LOCKER ROOMS. NO PLAN CHECK FOR LOW VOLTAGE WIRING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14046	19041-10000-51513	11860 W WEIR ST	90230	11	108B161   772	4218018012	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Issued	01/09/2020 12:00:00 AM	ADDRESS	33.99	-118.40755	Permit fee is $0.00 due to Assembly Bill. 1414. Plan check for a PV-1  9KW AC / 7.2KW DC , solar tile system with (2) inverters, (123) modules and (2) energy storage systems interconnecting through the load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14047	15041-20000-21461	1055 W 7TH ST 1ST FLOOR	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.0507	-118.26334	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LA CARE OFFICES. 1ST FLOOR. 940 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14048	14041-20000-24975	15039 W RAYMER ST	91405	6	189B145   729	2209031004	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Van Nuys		1272.10	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.21372	-118.46102	INTERIOR T. I.; CONVERT PORTION OF (E) WAREHOUSE TO TRADE SCHOOL.  3857 SQ FT.  PLAN CHECK FOR ENERGY ONLY UNDER 2013 BUILDING ENERGY EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14049	13041-10001-00113	590 N VERMONT AVE 1ST AND-4TH FLOOR	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM			PC Approved	05/21/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	MODIFICATIONS TO APPROVED SET OF ENERGY ONLY PLAN CHECK UNDER APPLICATION NUMBER 13041-10000-00113. PLAN CHECK ONLY. CHANGES ARE DELTA 3 AND CLOUDED****************************************************************************T.I.  Title 24 plan check for the first floor lobby and the fourth floor cafeteria.  Project is part of the the the projects that were plan checked under 12041-10000-07193 and 12041-10000-18381.  This is the 3rd phase of the entire project.  Plan check is for energy only and emergency lights.  This application was generated for fee purposes,  Double check fees and scope of work once applicant is ready to submitt for plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14050	13041-10000-31474	12424 W WILSHIRE BLVD	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.04135	-118.47058	Title 24 for a commercial building , ste 900, TI, emergency lighting within the suite.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14051	14041-20001-10081	3366 N WRIGHTWOOD DR	91604	2	159B173   314	2380038003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.13268	-118.37316	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14052	17041-10000-24061	14630 W NURMI ST	91342	7	222B149   226	2505011005	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.30738	-118.45145	PC for new (1)Tesla Powerwall 2 (7KW) connecting to new subpanel 200 A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14053	18041-20000-41265	623 E 111TH ST	90059	8	088-5A207 338	6071005032	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	33.93489	-118.26425	Plan check for a PV1 roof-mounted PV system. System size is 8.91 kWdc/7.92 kWac and consists of (33) modules, (33) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14054	18041-10000-09584	12777 W FOOTHILL BLVD	91342	7	216B161    30	2514004031	M1-1-CUGU	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.29191	-118.41323	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14055	17041-20000-10145	6555 W BARTON AVE #540	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.08785	-118.33475	ti to an existing commercial building.  adding new ligitng new controls to existing panels.  plan check for energy only.  total square footage 4970.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14056	10041-10000-06775	1800 S CENTURY PARK EAST 3rd floor	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	10/22/2010 12:00:00 AM	ADDRESS	34.06244	-118.41523	T-24 and emergency lighting plan check for a portion of the 3rd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14057	17041-10000-32264	2789 W OLYMPIC BLVD 101-301	90006	10	129B197   186	5078007030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.0529	-118.29436	PLAN CHCEK FOR FIRE ALARM SYSTEM FOR 3-STORY COMMERCIAL BUILDING. SYSTEM CONSIST OF 1 FIRE ALARM PANEL AND 55 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14058	17041-20000-23666	1648 N KINGSLEY DR	90027	13	148-5A195 129	5544015010	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			07/13/2017 12:00:00 AM			Reviewed by Supervisor	08/04/2017 12:00:00 AM	ADDRESS	34.10129	-118.30303	pv2install roof mounted pv system sized 18kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14059	13041-10000-33049	523 N CHESTNUT AVE	90042	14	154-5A235 290	5493032002	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.11619	-118.17348	"investigation fee paid on separate application: 14041 10000 01528.PV1 4KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(16)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]     'Expedited plan check per applicant request'BAS Number: 811359Address: 523 N CHESTNUT-----------------------------------------------NO: 95996  -- Building/Electrical/MechanicalCode Enforcement ""COMPLY WITH DEPARTMENT ORDER effective date 03/23/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". All permits shall be for the same time period limitation. If additional assistance is needed, please call Inspector MARK VAN SLOOTEN at (213)252-3058 of GENERAL ENFORCEMENT CENTRAL.  CEIS Case Number is 408143.(Created: IMSV7 / 03-29-11)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 95995  -- Building/Electrical/MechanicalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issued with effective date 03/23/2011 by Inspector MARK VAN SLOOTEN atphone# (213)252-3058.  CEIS Case Number is 408143.Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.(Created: IMSV7 / 03-29-11)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14060	16041-10001-37790	950 S BARRACUDA ST PV	90731		015B205    30	7440032905							Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	PIN	33.73353997	-118.26217778	EXPEDITE FEESPC FOR PV SYSTEM. TOTAL SYSTEM SIZE OF 1270KW WITH 3737 MODULES IN TOTAL AND 13 INVERTERS. ROOF MOUNTED. THIS IS FEED IN TARRIF PROJECT (FIT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14061	14041-10001-06055	11735 W HAMLIN ST	91606	2	180B169   795	2322020066	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			PC Approved	08/04/2014 12:00:00 AM	ADDRESS	34.18884	-118.38909	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV2, INSTALL 18.OO KW DC ROOF-MOUNTED AND ON CARPORT SOLAR ARRAY, UPGRADING 3 SUB PANELS(~100A).(4 )TRANSFORMERLESS INVERTERS:SMA AMERICA SB6000-TL-22-US & SB3800-TL-22-US & SB3000-TL-22-US. (72)MODULES: TRINA SOLAR TSM-PA05.08}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14062	19041-10000-12054	13130 W BURBANK BLVD	91401	4	174B157  1137	2345005028	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.17191	-118.41936	Replace fluorescent troffers with new LED retrofit kits, BLD #6, Indoor only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14063	13041-20000-12030	16001 W STRATHERN ST	91406	6	189B141    49	2206005015	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM			PC Info Complete	08/05/2013 12:00:00 AM	ADDRESS	34.21581	-118.48151	EXISTING FACTORY BUILDING. UPGRADE SERVICE TO 3000A. NEW SWITCHBOARD WITH TAP TO EXISTING SWITCH BOARD. PROVIDED FOR FUTURE LOADS PROVIDED BY OTHERS.  FUTURE LOADS TO MSB WILL REQUIRE FULL PLAN REVIEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14064	13041-20000-14079	10971 W QUEENSLAND ST	90034	5	120B157   397	4251009002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.02617	-118.42293	PV1 TWO STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.1KW. 20 PANELS AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14065	16041-10000-15773	4149 W PICO BLVD 101-104	90019	10	129B189   894	5081001030	C4-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.04792	-118.32627	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM OFFICE TO OFFICE/RETAIL DEMO AND ADD WALLS TO DIVIDE INTO 4 TENANT SPACES 1 OFFICE, 3 RETAIL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR EACH TENANT. TOTAL AFFECTED AREA IS 4040 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14066	13041-20000-13571	12059 W VENTURA PL	91604	2	165B165  1242	2368002010	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.14469	-118.39458	FULL PLAN CHECK FOR CHANGE OF USE FROM RETAIL TO NEW RESTAURANT. NEW 800A SERVICE, NEW PANELS, AND NEW CIRCUITS. 3424 SQRFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14067	18041-20000-38565	8257 N WOODMAN AVE	91402	6	192B153   835	2213016021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.22095	-118.43288	Commercial office tenant improvement.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14068	16041-10000-14957	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR WESTFIELD CENTURY CITY MALL PHSE II. 1351 FA DEVICES, ONE FA PANEL,4 COMMUNICATION PANEL AND 95 CONTROL PANEL . Phase III WAS INCLUDED WITH ADDITION OF 1496 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14069	17041-10001-46477	3217 N EASTERN AVE	90032	14	141A233    26	5213038036	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2014.01	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			PC Approved	04/09/2018 12:00:00 AM	ADDRESS	34.08244	-118.17829	DELTA 1 REVISIONS- UPDATED SINGLE LINE TO SHOW NEW FUSED MAIN DISCONNECT, LOWER AVILABLE FAULT CURRENT AT THE SERVICE POINT, CONDUIT FOR FUTURE PV SYSTEM, AND LOWER AIC RATING FOR THE SWBD. REDREW SERVICE ELEVATION (((((INSTALLATION IN NEW TENANT  SPACES PANELBOARDS, CIRCUITS , LIGHTING-ALL MINIMUM ELECTRICAL LOADS   IN ORDER TO SHOW TENANT SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14070	19041-10000-22720	18416 S WESTERN AVE	90248	15	060B193   109	6108001068	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	33.86332	-118.30895	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14071	18041-10000-26199	22450 W SHERMAN WAY	91307	12	183B101    99	2024016109	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.20073	-118.61672	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14072	16041-10000-00287	8680 W PICO BLVD	90035	5	132B169  1060	4303011002	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.05411	-118.38117	T-24, TI TO MARKET AND RESTAURANT AREA, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1959.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14073	10041-10000-01911	11055 W BURBANK BLVD	91601	4	174B173  1381	2337029028	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.02	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	02/03/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.17235	-118.37235	NEW FIRE ALARM SYSTEM FOR MCDONALD'S RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14074	15041-20000-34290	11929 W ALLEGHENY ST	91352	6	198B165   177	2631001016	RA-1, [Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	PIN	34.23743306	-118.39337734	Full PC for NEW 2 story school build.  1600A service. Total area is 118212 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14075	16041-20000-22509	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.04403	-118.2199	"""$0 permit fee due to senate bill 122""Plan check for PV roof mounted system. System size: 35kW with 275 modules and 5 inverters (7.6kW) on commercial Building. Note: Application need to assign Building Name"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14076	19041-20001-31263	23341 W LOS ENCINOS WAY	91367	3	171B093   322	2044018010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.16596	-118.6357	CHANGES TO APPROVED SET DELTA 1. RELOCATION OF PV MODULES AND ADD NEW METER.<<<PV1.  Install 16.38 kW roof mounted grid tied PV system.  (52) modules with (2) 7.6 kW rated inverters.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14077	17041-10000-21117	1150 S OLIVE ST STE 1650	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Info Complete	06/22/2017 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI, OFFICE UPGRADES. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14078	19041-10000-11878	649 S WALL ST	90014	14	127-5A211 353	5148023***	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	12/30/2020 12:00:00 AM	ADDRESS	34.04256	-118.24822	INSTALL NEW FA SYSTEM IN NEW HIGHRISE BUILDING WITH 439 DEVICES AND 1 FIRE ALARM PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14079	12041-10000-01261	7801 W MELROSE AVE	90046	5	141B177   529	5527010013	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	01/19/2012 12:00:00 AM	ADDRESS	34.08391	-118.35962	Exterior lighting for rooftop parking lot on a commerical retail building.  Plan check only for Energy.  (No unit number per applicant.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14080	17041-10000-11576	1245 W WILSHIRE BLVD #795	90017	1	132A207   288	5143017041	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM			PC Info Complete	04/10/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	PC for power and energy for TI of Cardiothoracic -doctors office- (NON-OSHPD). PC for nre lights and receptacles. Total sqft is 2047.Building # 17016-10000-08764**INTERIOR NON-STRUCTUAL TENANT IMPROVEMENT ON SEVENTH FLOOR OF EXISTING MEDICAL OFFICE (1932 S.F)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14081	16041-10001-14259	10614 N DEBRA AVE	91344	12	207B137   549	2679015024	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.26324	-118.48924	PV1. PC FOR A NEW SOLAR SYSTEM ON AN EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(21)MODULES-CANADIAN SOLAR CS6K-275M(1)INVERTER-SOLAREDGE SE5000A-USNOTE: PERMIT PAID UNDER PCIS#16041-90000-14259((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14082	12041-20000-15678	11860 W WILSHIRE BLVD #100	90025	11	129B145   914	4263007075	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.04692	-118.46366	Remodel of the existing health care facility.  The facility has 8 patient treatment beds.  Install new panel, branch circuits, and lighting.  Plan check for power and energy.  The facility provides General Care Services only on an outpatient basis.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14083	14041-10001-06161	541 S SPRING ST	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.04657	-118.2507	3/8/16: Supplemental to approved set on Delta-1:New (6) 100A panels and (3) 400A panels for designed load only. All new load shall be under a separated permit. ***NEW 2000A SERVICE FOR EXISTING ADAPTIVE REUSE BUILDING. THIS SERVICE IS FOR RETAIL TENANTS ONLY. PLAN CHECK FOR POWER ONLY. NO LOADS AT THIS TIME. SERVICE ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14084	19041-10000-33339	20165 W RINALDI ST STE 130,-140,150	91326	12	210B113   290	2701100007	(T)C4-2D, C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.27527	-118.57297	FULL PC FOR a first time  tennat build out covering (3) suit-130, 140 and 150 RETAIL spaces located  IN A CORE AND SHELL BUILDING. Scope includes new lighting and equipment with a total lighting area of 2332-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14085	17041-10000-07909	19601 S HAMILTON AVE	90502	15	057B197    81	7351033023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	33.85319	-118.28624	Plan check for power and energy for Divergent 3D printing area, the equipment is install  in unclassified location per SLM Printers Hazardous Materials Analysis provided by the applicant and by the Fire Dept. approval plan. Area of scope of work is approx. 4300 sq ft.B# 17016-10000-05827	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14086	19041-10000-06590	1503 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.09834	-118.32695	Tenant Improvement to existing commercial suite (1,724 SF).  Install new lights. T-24 Energy Only.Building Permit: 19016-40000-03249	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14087	11041-20000-17398	13275 N GOLDEN STATE RD	91342	7	225B141  1516	2604002059	(Q)M1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	PIN	34.31226914	-118.48573073	CLASSIFY AREA BY INSPECTION CLASS 1 DIV 2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14088	18041-10000-03653	3304 S SHELBY DR	90034	5	123B165   796	4311004014	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.03235	-118.40119	PC FOR NEW ESS (TESLA POWERWAL 2). PROPERTY HAS AN EXISTING PV. SCOPE INCLUDES NEW ESS, LOAD CENTER AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14089	19041-20000-36889	24364 W CRESTLAWN ST	91367	3	174B085   118	2047017019	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Issued	09/16/2019 12:00:00 AM	ADDRESS	34.17024	-118.65755	PV1. INSTALL 11.34 KW DC SOLAR SYSTEM WITH (36) MODULES AND OPTIMIZERS AND (1) INVERTER (SE10000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14090	18041-20000-17860	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.15713	-118.43792	New 1200A 480Y/277V service for future restaurant expansion.  New exterior lighting.Building permit filed under 18016-20000-08107.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14091	18041-10000-32760	229 N BROAD AVE	90744	15	027B205   219	7418031019	[Q]CM-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Issued	08/28/2018 12:00:00 AM	ADDRESS	33.77209	-118.26065	REMOVE INDOOR/OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES- T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14092	19041-10000-19565	23651 W BLYTHE ST	91304	12	189B093   331	2020007043	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.2143	-118.64271	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 26 MODULES (LONGI SOLAR 305) , 26 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE7600H-US).  SYSTEM SIZE IS 7.93KWdc and 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14093	19041-10000-27374	431 E 89TH ST	90003	9	096A207   155	6041023901	OS-1XL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	03/19/2021 12:00:00 AM		Issued	03/19/2021 12:00:00 AM	ADDRESS	33.9557	-118.26719	Note: Permit fees are $0 due AB 1414.PV2. New Solar system on existing commercial roof-top. Total system size is 52.70KWdc / 50.15KWac(170)Modules-CSUN310-60M(170)Microinverters- IQ7Plus-72-2-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14094	16041-10000-14563	1108 N LAGOON AVE	90744	15	033B205   814	7420018028	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.78496	-118.26734	PV1, addition to an (E) PV system. New Inverter (1) PVI-3.0-OUTD  and  (7) SOLAR CITY Modules. New system size is 6KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14095	13041-20000-24879	2716 S ELLENDALE PL A-D	90007	9	123B197  1480	5055013025	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.02988	-118.28859	Plan check for 600A service upgrade for existing apartment. Units A, B, C, D only. Methane ZONE. Please check concurrently with 13041-20000-24882 (service is on 13041-20000-24882)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14096	10041-20000-15335	3450 S WATT WAY LPB	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	03/08/2011 12:00:00 AM	ADDRESS	34.02275	-118.28604	energy plan check theatre	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14097	17041-10000-38354	10300 N VANALDEN AVE	91326	12	204B121   122	2728019001	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.25765	-118.54904	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.075KWdc / 11.2KWac.(35)MODULES-SUNPOWER SPR-X21-345-D-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14098	19041-10000-20906	12666 W PALMS BLVD	90066	11	114B153   815	4246003002	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.00796	-118.4426	[e-plan] Plan check for power only. Install 2 Energy Storage Systems @ 27KWH & 2 New load centers 1 125A Load Center & 1 200A Load Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14099	12041-10003-30783	"12746 W JEFFERSON BLVD ""1"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	CHANGES TO AN APPROVED SET OF PLANS, DELTA A. CHANGES TO INCLUDE INJECTOR PUMP. Plan check power and energy for Building 1. One story retail shell on top of common subterranean parking with Building 2, 3, and 4. Service supplying Building 1 and Building 2. Site located in methane zone. Modification to separate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14100	14041-10000-22099	6245 W DELFINO ST	91042	7	201B205   249	2571002030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Expired	09/14/2016 12:00:00 AM	ADDRESS	34.24944	-118.26708	Installation of roof mounted solar PV system.  Total system size = 7.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14101	16041-10000-20821	1141 N SEWARD ST	90038	4	144B185   565	5532023004	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Info Complete	06/14/2016 12:00:00 AM	ADDRESS	34.09194	-118.33331	Relocatin of 1200A  main switchboard.  in 3-story commercial building. reconnect to existing loads. misc permit to check condition of existing panels for series rating.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14102	10041-20000-01175	935 W 35TH ST Building C	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	08/04/2010 12:00:00 AM	PIN	34.02328797	-118.28705198	"Revisions to 08041-20000-21022New Building ""C"" at USC Campus (CNTV PHASE II).Request for Modification filed toallow 25% extra load in 50A hoist panels.( 03.05.2010  approved by E. Maalouf )."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14103	14041-10000-26965	900 N BROADWAY	90012	1	135A215   235	5414013900	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	PIN	34.06407564	-118.23656378	Fire alarm system for new 5 story apartment complex over commercial podium with 3 level subterranean parking.  1,012 Total devices with one FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14104	17041-10000-18966	2501 S COMPTON AVE	90011	9	117A213   107	5118010001	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.01586	-118.24681	NEW 1 STORY ADDITION TO 1 STORY WAREHOUSE AND PARKING LOT WORK. upgrade service. pc for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14105	12041-10000-02919	1809 W 11TH ST	90006	1	129A203    73	5136010026	CR-1-HPOZ	Central	Westlake	Pico Union		2095.20, 2098.20	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM	04/06/2012 12:00:00 AM		Permit Expired	04/30/2014 12:00:00 AM	ADDRESS	34.04901	-118.27769	New 44kw rooftop photovoltaic system on an existing apartment building.  152 modules and 3 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14106	17041-10000-16628	10250 W SANTA MONICA BLVD # 1935	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	First time tenant-Aesop- at Century City Mall Space 1935	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14107	15041-10001-24553	1963 S VERMONT AVE	90007	1	126B197   950	5075038003	CM-2	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	34.03849	-118.29177	02-02-2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 3. CHANGES INCLUDE THE CHANGE OF FIXTURES TYPE AND CHANGE OF T-24 CALCULATION.(((FULL PLAN CHECK  FOR A COMMERCIAL BLDG WITH NEW 600-AMP SERVICE AND 6-PANELS. TOTAL  48-CIRCUITS, 9-EQUIPMENT AND 5822-SQ FEET.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14108	15041-10000-11872	9216 S BEACH ST	90002	15	094-5A213 186	6048032042	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	33.95272	-118.24178	PV1, INSTALL  NEW 5.6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, TIE WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR32NE-WHT-D(1)INVERTER: ABB PVI-5000-OUTD-USA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14109	19041-10000-41408	927 N GALLOWAY ST	90272	11	129B129   860	4423019024	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.04629	-118.52101	$0 PER AB 1414[E-PLAN]. CHANGES TO APPROVED SET. REMOVING 1 MODULE FROM THE SYSTEM AND RECONFIGURING MODULES' LAYOUT. NEW SYSTEM DC SIZE IS 7.88KWdc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14110	15041-20000-22198	10025 N LARWIN AVE	91311	12	204B097    19	2724003095	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Expired	08/07/2017 12:00:00 AM	ADDRESS	34.25475	-118.6182	Plan check for PV roof mounted system. System size: 6.0kW with 22 modules and 1 inverter (6.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14111	16041-20000-15225	5248 W SANTA MONICA BLVD	90029	13	144B193   736	5537020029	[T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.09066	-118.30494	Plan check for Title 24 only for existing retail Bakery. Total area: 730 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14112	10041-10000-14418	15931 S MENLO AVE	90247	15	069B197   162	6120015039	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	08/31/2010 12:00:00 AM	ADDRESS	33.88632	-118.28944	New 13.0 kw solar photovoltaic system on residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14113	18041-10000-11516	702 N FLINT AVE	90744	15	030B209   273	7424022019	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.77958	-118.24918	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14114	18041-20000-20006	8335 N SPARTON AVE	91402	6	192B157   605	2637034020	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.22247	-118.42589	Plan check for PV roof mounted system, system size: 13.11kW with 38 AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14115	19041-10000-13331	2423 E 1ST ST	90033	14	127-5A223 177	5180002029	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.04348	-118.20886	PV2. PC FOR PV SYSTEM 14kW. SYSTEM INCLUDES (31)MODULES JA SOLAR JAM 72S01-370/PR W/ P850 OPTIMIZERS . (1) CENTRAL INVERTER SOLAREDGE 14.4KUS .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14116	16041-10000-07541	1700 E MARTIN LUTHER KING, JR BLVD	90058	9	115-5A215  65	5117021020	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	01/13/2023 12:00:00 AM	ADDRESS	34.0097	-118.24278	"FULL PC FOR POWER AND ENERGY FOR A NEW 1-STORY, 218'0"" X 404'0"" MANUFACTURING/WAREHOUSE/OFFICE BUILDING."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14117	15041-10000-18513	2402 E ANAHEIM ST UNIT 30/31	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Issued	08/31/2015 12:00:00 AM	ADDRESS	33.78054	-118.23195	PLAN CHECK FOR HAZARD LOCATION CLASS 1 DIV2.REFINERY REPLACEMEMT OF EXISTING CIRCUIT BREAKERS AND RECEPTACLES TO POWER COKER CRUSHER CAR UNIT 30 AND UNIT 31.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14118	15041-10001-26505	705 N ALFRED ST 1-2	90069	5	141B173   423	5528001054	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.08391	-118.3755	CHANGES TO AN APPROVE SET, SCOPE INCLUDES THE ADDITION OF FIXTURES IN RESTROOMS. ADDED 5 NEW CIRCUITS NOTE CHANGES ON DELTA 1.  (((TI TO AN EXISITNG TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS. PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 3571.2008 STANDARDS APPLY PER INSPECTOR RODNEY SABEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14119	15041-20001-35736	1622 N WILCOX AVE	90028	13	148-5A187 245	5546007006	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM			PC Approved	01/08/2016 12:00:00 AM	ADDRESS	34.10042	-118.33085	01/08/2016 Changes to an approved set of plans. Plan check is for Delta B only. Smoke detectors have been added to rooms and shown on floor plans.*****Previous Work Description*****SYSTEM UPGRADE TO 800 AMPS.  EXISTING THREE STORY HOTEL BUILDING 52 ROOMS.  PLAN CHECK FOR POWER AND ENERGY. 9332 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14120	10041-10000-19991	11500 W NATIONAL BLVD 1-18	90066	11	120B153   778	4250013012	RD1.5-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	01/30/2012 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.02428	-118.4351	18 units townhome. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14121	19041-10000-31700	1722 S WESTWOOD BLVD #105	90024	5	129B153   286	4325022004	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.05135	-118.43811	Energy plan check for Massage Parlor T.I. Scope includes new lighting and and equipment with a total lighting area of 500-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14122	17041-10000-43810	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.04166	-118.26677	"PC FOR INSTALLATION FOR SIGN ON BUILDING FACADE (HIGH RISE)ELECTRICAL EQUIPMENT TO BE LOCATED ON THE 5TH FLOOR OF PARKING STRUCTRE. SCOPE INCLUDES TRANSFORMERS AND DISTRIBUTION BOARDS. B# 17016-10000-19984ELECTRICAL CORE AND SHELL 14041-10000-16846Supplemental permit to 13010-10000-04232: INSTALL STRUCTURAL GRID ON FACADE FOR SIGN FRAME (at 3 locations for signs): 112'-4"" x 52'-9"", 121'-3"" x 65'-4"", 85'-7"" x 52'-9""),  AND ARCHITECTURAL FEATURES (at 3 locations): 15'-6 7/16"" x 68'-6 1/16"", 30'-2 13/16"" x 68'-6 1/16"", 83'-9 3/8"" x 14'-11 1/2"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14123	18041-10001-26142	2010 S CENTURY PARK EAST Parking	90067	5	132B161    28	4319001803	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM			PC Approved	12/31/2019 12:00:00 AM	ADDRESS	34.05986	-118.413	Changes on approved set and address delta 2 changes. Changes include reduction of lighting. Title 24 energy plan check. Total affected area: 12,331 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14124	13041-10000-23028	2646 N GRIFFITH PARK BLVD	90039	4	150A205   101	5434037021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			08/23/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.10629	-118.27178	PLAN CHECK FOR FIRE ALARM IN A PRIVATE SCHOOL. INSTALLATION OF 7 DEVICES AND 1 FIRE ALARM CONTROL PANEL, ADDITIONAL DEVICES ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14125	14041-10000-22373	1901 S BUNDY DR BLDG 1	90025	11	123B149   330	4259018014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.03497	-118.45709	New fire warning system for building 1. 1 panel 3 booster power supplies and 140 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14126	10041-20000-23479	8736 N CANBY AVE	91325	12	195B125   748	2769025016	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	10/19/2011 12:00:00 AM	ADDRESS	34.22975	-118.53467	Service upgrade to 800 amp for Time Warner Hub (Phase I).  New service, switchboards, ATS, transformer, subpanel.  Note - Generators, branch circuits, and lighting will include in phase II and III as shown on plan.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14127	13041-20000-29276	3131 S FIGUEROA ST	90007	9	120A203    61	5123010012	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.02389	-118.27894	PC FOR T24 ENERGY ONLY. NEW LIGHTING. EXISTING CLASSROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14128	19041-10000-49960	1100 S WALL ST	90015	14	124-5A211  88	5145024026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.03625	-118.25418	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY. 3RD LEVEL & ROOFTOP PARKING  (INDOOR/OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14129	18041-30000-03001	14967 W CAMAROSA DR	90272	11	123B129   257	4411021008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.03474	-118.52308	PLAN CHECK FOR POWER FOR NEW SINGLE FAMILY DWELLING. SERVICE SIZE = 600A WITH OVER 400A OF CONNECTED LOADPlan check only. Permit was pulled under Building ApplicationBuilding Application Number: 15010-30000-04290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14130	10041-10000-24876	4501 W COLORADO BLVD BLDG B-1	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	INTERIOR RENOVATION OF EXISTING MANUFACTURING AREA. ADD CIRCUITS, MOTOR, AND RELOCATE LUMINAIRES. NO NEW PANEL ADDED. SOME PANELS ARE LOCATED IN HAZARDOUS AREA. EPC FOR POWER AND ENERGY. (BLDG#1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14131	13041-20000-05084	550 S HOPE ST Ste 1000	90071	9	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.04989	-118.25574	Change to lighting in an existing high rise building.  New load is less than 400 amps per applicant.  If load is greater than 400 amps including work for other floors on separate permits, full plan check may be required.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14132	12041-20000-11586	12234 W MONTANA AVE	90049	11	129B141   435	4264011007	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			05/21/2012 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.04871	-118.47456	New 6 units three story apartment building.  Variance to separate the fire alarm approval was submitted and approved on August 30, 2012.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14133	10041-10000-09400	2302 E 15TH ST	90021	14	120A217   227	5167012032	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02129	-118.23113	NEW 600 AMP SERVICE. PLAN CHECK FOR POWER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14134	17041-10000-18505	2049 S CENTURY PARK EAST 3rd floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK FOR HIGH RISE BUILDING - T-24 ONLY FOR T.I. RENOVATION TO PUBLIC RESTROOMS ON 3RD FLOOR. TOTAL AFFECTED AREA 410 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14135	12041-20000-09635	3600 W WILSHIRE BLVD Ste 100C	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Approved	04/27/2012 12:00:00 AM	ADDRESS	34.06156	-118.30335	Revisions to 11041-20000-23698T.I.  Remodel of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14136	15041-10000-35965	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Public Safety Only			10/27/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	33.94955	-118.38214	FIRE ALARM REPLACEMENT AND UPGRADE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14137	12041-10000-23780	3817 S GRAND VIEW BLVD	90066	11	111B157    67	4235023030	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM			PC Approved	10/05/2012 12:00:00 AM	ADDRESS	34.00421	-118.4309	Ti in a restaurant. EPC is for T24. single story, indoor and outdoor title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14138	19041-10000-52076	14435 W BURBANK BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	06/25/2020 12:00:00 AM		Issued	06/25/2020 12:00:00 AM	ADDRESS	34.17235	-118.44775	PLAN CHECK FOR TITLE 24 ONLY FOR BANK - TOTAL AFFECTED AREA = 2518 SF. SCOPE OF WORK INCLUDES INSTALLATION OF NEW PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14139	15041-20001-26704	5441 N YARMOUTH AVE Unit #11	91316	5	174B129   960	2162010006	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Apartment			10/13/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	34.16964	-118.52051	Installation of roof-mounted solar PV system at a 11-unit apartement build. This scope is on the Unit #11. Total system 2.85 kW DC. (10) modules: SW 285W Mono, (1) inverter: ABB PVI-3.0-TL-OUTD. Permit under 15041-90000-27596	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14140	17041-10000-43290	221 N WESTMORELAND AVE	90004	13	138B197   515	5501008024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.07516	-118.28805	$0 fee per SENATE BILL 1222PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS  54.4KWdc / 66.6KWac.(160)MODULES-REC REC340TP72(80)OPTIMIZERS-P700(2)INVERTERS-SOLAREDGE SE33.3KUS 480Y/277V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14141	14041-10000-04416	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.04896	-118.25139	T24 for energy. High rise building. Work is done on eleventh floor. Total area 3131 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14142	16041-10002-27162	11811 W SAN VICENTE BLVD	90049	11	129B145    52	4401017018	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.0532	-118.46895	"PC FOR CHANGES TO APPROVED SET PER INSPECTION FOR UPSIZE GROUNDING AND RELOCATION OF PANEL ""R"" AND CHANGE OF ENGINEER. LETTER OF APPROVAL FORM OWNER HAVE BEEN ATACHED TO PLAN FOR CHANGE OF ENGINEER. THIS IS PLAN CHECK  ONLY!"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14143	17041-10000-12203	2211 E OLYMPIC BLVD	90021	14	121-5A217 320	5167001056	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Closed	07/25/2017 12:00:00 AM	ADDRESS	34.0263	-118.23301	PC for energy only, Outdoor Title-24. Remove HID and Install new LED fixtures. Area: 10,150 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14144	19041-20000-50242	584 W CYPRESS AVE	90065	1	144A219   322	5446007027	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	34.08777	-118.2217	PV2 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 2.59 KW DC/2.03 KW AC. SCOPE OF WORK CONSISTS OF (7) PV MODULES WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14145	16041-10000-21621	16200 W MULHOLLAND DR	90049	11	159B137   491	4490003005	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.12965	-118.48562	PV1 INSTALL NEW 5200 W DC ROOF-MOUNTED SOLAR ARRAY ON A PRIVATE SCHOOL.(20) MODULES: CANADIAN SOLAR CS6P-260P(20) MICROINVERTERS: ENPHASE M215-60-2LL-S2X	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14146	18041-10000-07385	1711 S LINCOLN BLVD	90291	11	111B149  1401	4241018031	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM			PC Info Complete	07/16/2018 12:00:00 AM	ADDRESS	33.99638	-118.45796	PC for power and energy for change of use from market to restuarant. Installing new lights, receptacles and equipment. Total area is 2921sqft. Occupancy is A2 with max occupancy at 794. B#16016-10000-19494	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14147	17041-10003-08208	929 W JEFFERSON BLVD #1670	90007	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	PC for supplemental changes to approved set. PC includes removal and relocation of loads in panels A,B and LWC1. All changes clouded under delta 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14148	16041-10000-15692	12602 W VENTURA BLVD	91604	2	162B161   146	2384022024	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.14333	-118.40789	CHANGE OF USE  OF A PORTION OF AN EXISTING RETAIL BUILDING TO A PHARMACY AND AN INTERIOR TI. USE (E) CIRCUITS, PC FOR T-24 (lighting only, no new receptacles). TOTAL AREA: 2,280 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14149	15041-10000-24962	8533 N WOODLEY AVE	91343	12	192B137   107	2689025027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.22563	-118.48545	$0 permit fee is due to State Senate Bill SB-1222. PV 1 INSTALLMENT OF NEW 19.293 KW DC ROOF MOUNTED SOLAR ENERGY SYSTEM IN A SINGLE FAMILY HOME. (59) MODULES: SUNPOWER SPR327E-WHT-D (3) INVERERS: POWERONE BLACK PV1-6000-OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14150	18041-10001-14980	1231 N SPRING ST	0	1	135A215   169	5414014001	C2-2, [Q]C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	PIN	34.06461924	-118.23604048	PLAN CHECK ONLY. DELTA 2 CHANGES TO AN APPROVED SET. CHANGES TO DWP DISTRIBUTION AND ROUTING. RELOCATING HOUSE PANEL TO MATCH SERVICE ELEVATION. AIC RATING HAS CHANGED.  All changes are clouded. Original scope: FULL PLAN CHECK, CHANGE OF USE FROM MANUFACTURING TO RETAIL/OFFICE AND RESTAURANT BUILDING.  SCOPE INCLUDES A NEW 2000A 480/277V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW HOUSE PANELS, AND NEW CIRCUITS. B#14016-10000-03788	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14151	18041-10001-22421	16127 W DEARBORN ST	91343	12	198B141   552	2671020010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	03/22/2019 12:00:00 AM	ADDRESS	34.23761	-118.48366	SUPPLEMENTAL FOR CHANGES TO APPROVED SET - PANEL UPGRADE FROM 200A CENTER FEED TO 225A PV END FEED. CHANGES ARE NOTED UNDER R2PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 11.685KWDC /10.95KWACSCOPE INCLUDES 41 MODULES WITH OPTIMZERS AND CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14152	11041-20000-00582	13050 W SATICOY ST Unit 6	91605	2	186B161   435	2303023001	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.20703	-118.41729	Install general lighting in hazardous rooms.  All light fixtures shall be listed for the useed in hazardous location.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14153	12041-10000-09771	1200 S CLUB VIEW DR 10 North	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00, 2657.00	Electrical	Electrical	Apartment			04/30/2012 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.06748	-118.42481	"Expand electrical systems to a new residential unit #10-North on the 10th floor.   Square footage is 3,785, the load is 143A, and occupancy is less than 99 - per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting in the common areas only (Elevator is located in private area of the residence per applicant).  Permit is under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14154	17041-20003-46290	6150 N LAUREL CANYON BLVD BLDG J	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	Changes to approved set.  Revisions to transformer and building distribution grounding details, loop distribution overcurrent protection ratings to address coordination, and miscellaneous SLD revisions to reflect current field conditions.  (((Changes to approved set.  Extensive SLD revisions and miscellaneous floor plan changes throughout.  Plan check only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14155	15041-20001-33467	21608 W BERMUDA ST	91311	12	207B105   146	2722030017	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			PC Approved	11/03/2015 12:00:00 AM	ADDRESS	34.2662	-118.60051	EXPEDITE PER APPLICANT REQUEST.(((PV1. NEW ROOF MOUNTED PV SYSTEM ON EXISTING RESIDENTIAL HOUSE. TOTAL SYSTEM SIZE IS 11.20KW DC OR 9.8KW AC.(40) MODULES-SUNMODULE PLUS SW 280 MONO BLACK(2) INVERTER-FRONIUS PRIMO6.0 AND FRONIUS PRIMO 3.8 (1)100A LOAD CENTER)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14156	10041-20000-15048	1050 W CHILDS WAY	90089	8	120B197   929	5039002030	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.02262	-118.29103	lighting configuration and adding some receptacles. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14157	12041-10000-10793	17433 W TRAMONTO DR	90272	11	126B117   195	4416004034	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.04246	-118.55696	Note that permit fee is in INSPECTION FEE PERIODNote that Plan check was done on plans for the main building and for the accessory bbuilding (10010-10000-02003) on this application. A second plan check application for the accessory building was filed such that permit fee for that building will be on that new application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14158	19041-10000-44165	990 W 190TH ST #560	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	33.85813	-118.29505	TI IN AN EXISTING COMMERCIAL/OFFICE AREA IN SUITE#560. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 19016-10000-14598	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14159	18041-20000-20399	6921 N VARNA AVE	91405	2	183B157   670	2328016016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.19635	-118.42526	plan chgeck for roof mounted pv system for 8.4kva system - system consist of central inverter solaredge SE7600A-US with 28 modules (p320 optimizers). with battery bck up system rated 9.8kwh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14160	16041-10000-03054	10209 N DE SOTO AVE	91311	12	204B109   262	2747001027	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Issued	03/23/2016 12:00:00 AM	ADDRESS	34.25567	-118.58876	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.405KWdc / 8.250KWac.(33) MODULES-SOLAR WORLD SW 285 MONO(33) MICROINVERTERS-ENPHASE M250-60-2LL-S2X	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14161	15041-10000-42022	763 W 110TH ST	90044	8	088-5A199 202	6075004004	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	33.9357	-118.28911	PV1 INSTALL 6.75 KW D ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(25) MODULES: SUNEDISON (25) MICRO INVERTER:  ENPHASE M215-60-2LL-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14162	12041-10000-09344	1 S CHESTER PL	90007	1	123A203   124	5124029016	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.03141	-118.27736	Change of use from dormitory to offices at Mount St. Mary's College.  All new 400A service, transformer, equipment, elevator, circuits.  Full plan check for Power and Energy. Site located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14163	17041-20000-30775	8232 W JAYSEEL ST	91040	7	208-5A193 335	2555016015	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.2654	-118.31271	PV1.  Install 5.5 kW roof mounted grid tied PV system, centerfed interconnection.  (19) modules with (1) 4.6kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14164	16041-20000-26903	853 S LUCERNE BLVD 1-18	90005	4	132B189   432	5090020002	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.05895	-118.32596	Plan check for New 18 units appartment. Total area: 15,051 sq ft.Fire alarm has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14165	19041-10000-40480	929 N COLE AVE 1ST FLR	90038	13	144B185  1050	5533021028	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.08789	-118.33004	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT OF EXISTING OFFICE SPACE WITH ENCLOSE PORTION OF EXISTING COVERED PATIO. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 4643 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14166	13041-10000-23898	18001 S FIGUEROA ST SUITE G	90248	15	063B201   174	7339008001	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	33.86778	-118.28182	Remove (E) HID light fixtures and install new light fixtures as per DWP rebate program.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14167	17041-10000-40273	12341 N BRADFORD PL	91344	12	219B129   556	2606029028	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.29463	-118.51298	PC for rooftop 4.02kW PV system. Installing 12 AC modules and new 100A load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14168	19041-10001-52931	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM			PC Approved	01/29/2020 12:00:00 AM	ADDRESS	34.08469	-118.4849	SUPPLEMENTAL FOR EXPEDITED FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14169	19041-10000-51149	700 W ROME DR	90065	1	148-5A221  14	5465002029	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.10317	-118.21455	NEW PV1 INSTALLATION 7.37KWdc (5.28KWac) using 22 LG335NIC-A5 MODULES & 22 ENPHASE IQ7-60-2-US(240) MICROINVERTERS. CONNECTED TO A 200 AMP EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14170	18041-10000-08606	13449 W VAN NUYS BLVD	91331	7	207B157   716	2619025003	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.26327	-118.42626	REPLACE OUTDOOR EXISTING FIXTURE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14171	15041-10000-14488	658 S WESTERN AVE	90005	10	132B193    69	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	PIN	34.06145284	-118.30870407	TI-24 FOR AN (E) COMMERCIAL BUILDING, BANK OF AMERICA. NEW LIGHTING CONNECTING TO EXISTING PANELS. PC FOR ENERGY.  TOTAL SQ. FT. 1584	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14172	14041-10000-31585	12746 W JEFFERSON BLVD #2103	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	TI for yogurt shop.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14173	15041-10000-42954	3400 N CAHUENGA BLVD WEST LV 2	90068	4	159B181   336	2425001061	C2-1LD	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.1318	-118.35189	T-24 PC ENERGY ONLY, TI TO (E) OFFICE SPACE ON SECOND FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES ON CONFERENCE ROOMS AND LOBBY WAY/RECEPTION. TOTAL SQ. FT. 1623.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14174	16041-20000-37282	5340 S ALLA ROAD	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	33.9773	-118.42567	Switchboard for (E) 2-story commercial office building to be refurbished with new circuit breakers and new 4000A bussed vertical switchboard section.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14175	13041-10002-05723	8425 N LAUREL CANYON BLVD	91352	6	192B165   289	2633006018	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM			PC Info Complete	05/29/2014 12:00:00 AM	ADDRESS	34.22407	-118.39842	Changes has made to a approved set of plan.T24 has changed. Changes  incldes series ratings, power, distribution and everything.  {{{PLAN CHECK FOR POWER AND ENERGY. CONVERTING 3 TENANT RETAIL SPACES INTO 1 LARGE TENANT SPACE (99 CENT STORE). TOTAL SQRFT:15319. USING EXISTING SERVICE BUT UPGRADING PANELS. ALL NEW PANELS HAVE ALL NEW LOADS.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14176	17041-10000-33613	11417 N BLUCHER AVE	91344	12	213B145   174	2662001023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.2778	-118.47114	PC for rooftop PV system in SFD. Total 29 modules with optimizers and 7.6kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14177	14041-20000-33756	3710 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			PC Approved	12/17/2014 12:00:00 AM	ADDRESS	34.02027	-118.28994	Plan check for energy only. Repartition units 203-206 into one large lounge, 910sqft. New lighting and relocate existing lighting (incl. emergency). Ronald Tutor Hall of Engineering (RTH) in USC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14178	15041-10000-38755	720 E WASHINGTON BLVD	90021	14	121-5A209 107	5131005007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.02762006	-118.25646467	Installation of new FA. to an existing apartment building (4 story building). Scope: (1) FA, (3) Control Panels, (1) communication panel, (176) FA devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14179	19041-10000-02076	3053 W OLYMPIC BLVD	90006	10	129B193   266	5080032024	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.05278	-118.30185	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14180	14041-10000-18626	12234 W MONTANA AVE	90049	11	129B141   435	4264011007	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			07/10/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.04871	-118.47456	INSTALLATION OF NEW FIRE ALARM SYSTEM IN EXISTING LOW RISE APARTMENT BUILDING.  SYSTEM SIZE = 65 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14181	14041-10000-07932	14175 W TERRA BELLA ST	91331	6	198B153   313	2644012002	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Expired	05/23/2016 12:00:00 AM	ADDRESS	34.24119	-118.44212	PV1,INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(16) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14182	16041-10000-36237	3131 S HOOVER ST Suite 1920	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.02611	-118.28472	PC for power and energy for TI for new Trader Joes in existing building #9. Trader Joes to be served by existing building/landlord service for 600 Amp. Square footage for tenant space is 13738 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14183	19041-20000-25636	16050 W HORACE ST	91344	12	210B141   836	2667006007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.26982	-118.48197	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS  6.27KW DC/5.985KW AC. SCOPE OF WORK INCLUDES (19) PANASONIC PV MODULES WITH ENPHASE IQ7X MICROINVERTERS AND A 100A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14184	18041-20000-03233	2116 E SACRAMENTO ST	90021	14	123A217   246	5166006016	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.03042	-118.22922	Change of use from warehouse to office.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14185	14041-20000-17564	15760 W VENTURA BLVD Ste 1915	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.1552	-118.47684	(E) commerical office remodel in an (E) commercial highrise bldg.  Plan check for energy standards due to changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14186	17041-20001-38682	15115 W ROXFORD ST	91342	7	228B145   808	2502027***	(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.31955	-118.46279	expeditepv1istall roof mounted pv system sized 5.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14187	14041-10001-01495	8012 S RAYFORD DR	90045	11	099B157   620	4114035019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	33.96385	-118.42558	Expedited RSES plan check per applicant request.{{PV1, Install 7 kW DC roof-mounted solar array for a two story house, interconnect with existing service panel.(1) Transformerless inverter(s): SOLAREDGE SE6000A-US. (28) Modules: TRINA SOLAR TSM-250PA05.18.(28) Optimizers: SOLAREDGE OP250-LV-MC4CM-2NA}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14188	18041-20001-02660	9750 N ANDORA AVE	91311	12	201B097    78	2724009012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM			PC Approved	02/08/2018 12:00:00 AM	ADDRESS	34.24788	-118.6225	SUPPLEMENTAL PERMIT FOR PLAN TO BE EXPEDITED------PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 11.4KVA CONSISTING OF 1 CENTRAL INVERTER(SOLAREDGE SE11400A-US), AND 35 MODULES WITH P400 POWER OPTIMIZERS. PLAN CHECKER TO VERIFY SPECIFICATIONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14189	14041-10000-19998	2232 S LINCOLN BLVD	90291	11	108B149   297	4242001032	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	33.9947	-118.45367	Title 24 plan check only.  Total area = 2,105 sq. ft.TI to existing boys and girls club.  Remodeling of 5 offices including lighting, exit signs, and recepticles.Building application was submitted before title 24 part 6 effective date.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14190	12041-10000-04846	1238 E OLYMPIC BLVD	90021	9	123A213    49	5132006011	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	03/02/2012 12:00:00 AM		Permit Finaled	09/07/2012 12:00:00 AM	ADDRESS	34.03259	-118.24506	T. I. - COMMERCIAL SPACE. P/check for compliance with lighting requirements of T-24 including emergency egress lighting. (Load < 400A)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14191	17041-10000-21107	541 S SPRING ST # 111	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Approved	07/12/2017 12:00:00 AM	ADDRESS	34.04657	-118.2507	PC FOR TI  IN A RSTAURANT , DINNING SPACE TITLE- 24 ENERGY ONLY.  INSTALLING NEW LIGHTS TOTAL AFFECTED AREA 631 SQ.FT. BL # 17016-20000-11620	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14192	12041-10000-19579	3002 S MIDVALE AVE	90034	5	123B157  1152	4254008003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.02983	-118.42145	Plan check T24 Energy/Emergency lighting for office area TI on 2nd story of existing Traders Joe. Permit for new light fixtures and receptacles on existing branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14193	10041-10000-08122	6370 W SUNSET BLVD	90028	13	147A187   584	5546015047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.09768	-118.32832	T.I. to existing building of culinary school.  Install general and emergency lights in kitchen, classroom, and library areas as shown on plans.  P lan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14194	15041-10000-04286	9801 N ETON AVE	91311	12	201B105   116	2746004017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.24838	-118.59458	Title 24 plan check only.  Total area = 8,064 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14195	16041-20000-37680	5900 W WILSHIRE BLVD 21 flr	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.06237	-118.35809	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check foe energy and em lighitng only.  total square footage 6125 in the 21th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14196	17041-10000-05591	1929 W PICO BLVD	90006	1	129A201   251	5136022027	CM-1	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.0467	-118.28113	NEW FIRE ALARY SYSTEM FOR A COMMERCIAL BUILDING SCOPE INCLUDES 111 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14197	18041-20000-16927	2221 W BEVERLY BLVD	90057	13	136-5A205 262	5157018058	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.06759	-118.27198	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from pharmacy to bakery/tenant improvement. Total lighting area = 2,141 sq. ft.Note: Building permit has been issued under 17016-10000-04921	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14198	18041-20000-01544	7733 N HASKELL AVE	91406	6	189B141   250	2206011039	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.21117	-118.47511	ti to an existing commercial building.  adding new lighting to bathrooms only.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14199	11041-10000-19889	2701 E MEDIA CENTER DR	90039	1	150B213  3655	5442032003	[Q]M2-1-CDO, [Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.00	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	PIN	34.10920885	-118.24409118	Electrical and energy plan check.Conduit only permit, issued 11/07/2011	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14200	11041-10000-11041	145 S SPRING ST	90012	9	130-5A213  30	5149001003	C2-4D	Central	Central City	Downtown Los Angeles		2073.00, 2074.00	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	03/21/2012 12:00:00 AM	ADDRESS	34.05196	-118.24563	REPLACING EXISTING & OLD MCCD WITH NEW DISTRIBUTION PANEL.  ALL NEW MOTOR CONTROL PANELS TO BE USED WITH EXISTING EQUIPMENT LOADS.  PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14201	12041-10000-17316	18011 W SHERMAN WAY	91335	3	183B125    90	2121004021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.20135	-118.5258	PV2 - NEW PV SYSTEM FOR A COMMERCIAL PARKING LOT/CAR PORT AREA. 41.04 KW DC (STC)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14202	19041-10002-01690	1707 W 265TH ST	90710	15	030B193    79	7411028025	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM			PC Approved	03/07/2019 12:00:00 AM	ADDRESS	33.78107	-118.30745	"DELTA ""D"" CHANGES TO APPROVED PLANS FOR RELOCATING THE ""DC-DISCONNECT"" AND INSTALLING GROUND RODS AT THE DETACHED BUILDING.<<<<PV1. NEW SOLAR SYSTEM WITH STORAGE BATTERY ON EXISTING RESIDENTIAL HOME. TOTAL SYSTEM SIZE IS 8.96Kwdc / 7.6KWac. TOTAL STORAGE BATTERY 9.8KWH LG CHEM RESU10H  (28)MODULES-PANASONIC GROUP VBHN320KA01(28)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE7600A-USS>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14203	12041-10000-09065	1443 W JEFFERSON BLVD	90007	8	120B197   622	5040002002	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			Reviewed by Supervisor	06/11/2012 12:00:00 AM	ADDRESS	34.02563	-118.29872	T.I. to an existing warehouse.  New 800A service, panels, lighting and circuits.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14204	14041-20001-16469	18333 W RANCHO ST	91356	3	168B125   527	2184058003	A1-1XL	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.15442	-118.53257	Expedited plan check per applicant request.  PV1.  Install 12 kW roof-mounted, utility-interactive PV system.  2 inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14205	14041-20000-03497	11250 N WOODLEY AVE	91344	12	210B141   160	2666018002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.27515	-118.48448	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14206	12041-10000-20531	14823 W SATICOY ST	91405	6	186B149   182	2210033005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10, 1272.20	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.2086	-118.45618	Plan check new roof mounted 8.502KW Photovoltaic (transformerless inverters) system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14207	18041-10000-06940	12121 W VICTORY BLVD STE 110	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.18684	-118.3977	Plan check power and energy first time tenant Ross Dress For Less. with 600A distribution. Total area: 32,276 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14208	12041-20000-21192	1835 S SEPULVEDA BLVD	90025	5	126B153   135	4323026019	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.04494	-118.44233	Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14209	14041-10000-11716	14818 W CALAHAN ST	91402	6	198B149   518	2651005011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.23626	-118.45616	PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZEER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(23) MODULLES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14210	18041-10000-33932	256 E WINSTON ST	90013	14	127-5A213  24	5148010031	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Issued	09/06/2018 12:00:00 AM	ADDRESS	34.04553	-118.24552	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14211	11041-10000-08834	2049 S CENTURY PARK EAST 18th floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			PC Approved	05/02/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14212	12041-10001-05565	1145 S GRAND AVE	90015	14	126A207   315	5139028***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM			PC Info Complete	03/21/2012 12:00:00 AM	ADDRESS	34.04067	-118.26314	Previously approved title 24,  Plan check for ti  high rise mixed use bldg, 1 75 K transformer and 2 ckts and a panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14213	15041-20000-22495	1501 N UMEO ROAD	90272	11	132B133   117	4425004012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.05905	-118.50501	Plan check for New single -family dwelling with 1000A servicePlan check only. Permit pulled under Building application number 14010-30000-03786	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14214	17041-10000-43510	8609 N REMICK AVE	91352	6	192B165    95	2634039016	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM			Reviewed by Supervisor	12/15/2017 12:00:00 AM	ADDRESS	34.22638	-118.40089	New rooftop solar system on SFD, 9.8 kW AC. Install (30) AC modules, (1) 125A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14215	17041-10000-28369	1801 S LA CIENEGA BLVD	90035	10	126B173     3	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.04434	-118.37702	REMOVE HID  FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14216	14041-20001-08546	6116 N CAPISTRANO AVE	91367	3	177B101    96	2039029026	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.18144	-118.6172	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14217	16041-20000-14709	11717 N KILLIMORE AVE	91326	12	216B121   590	2872009005	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.28492	-118.54578	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. (32) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14218	12041-10001-09339	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.2426	-118.55846	((((( Addition of 1 ckt, repacing panel from 225 amps to 400 amps and addition track lites to title 24.)))))))))))))))))))))  REMODELING TO EXISTING SUPERMARKET W/ ADDITION OF METAL CANOPY AT LOADING DOCK AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14219	14041-20000-34615	6033 W CENTURY BLVD SUITE 1050	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	33.94572	-118.38954	TI IN SUITE 1050. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14220	17041-20000-24360	1119 S SANTA FE AVE	90021	14	123A217   307	5166010010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.02998	-118.23018	Change of use from machine shop to retail.  Plan check for power and energy.  BUILDING PERMIT# 15016-10000-22154	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14221	15041-20000-18702	6320 N TOPANGA CANYON BLVD G-1615	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title-24 (energy).  Total area = 1,693 sq. ft.  T.I. to commercial first time tenant space.  New lighting, recepticles, and HVAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14222	13041-20000-14887	222 W 6TH ST	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	33.73887	-118.28305	RENOVATION OF INTERIOR OFFICES. NEW LIGHTING FIXTURES AND CIRCUITS. PART OF HIGH RISE. TOTAL AREA 11300 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14223	11041-10000-23329	9043 N RESEDA BLVD	91324	12	195B125    56	2770004006	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.23486	-118.53635	Subdividing a retail space to 4 tenants.  New 1000A service and circuits.  Plan check for POWER and Energy.((((  this permit is for core and shell only , all ti work is deffered for future tenants))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14224	18041-20000-10335	10508 W WOODBRIDGE ST	91602	4	165B177   593	2424013011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.14874	-118.35957	PV1.  Install 15.2 kW roof mounted grid tied PV system on single family dwelling and detached structure.  (50) modules with (2) 7.6 kW rated string inverters using power optimizers.Fees $16.36 due to California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14225	13041-20000-15141	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.15777	-118.43065	T24 FOR NEW PARKING LOT FOR HIGH SCHOOL. SCOPE OF WORK: 21889 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14226	16041-20000-40109	18710 W VINTAGE ST	91324	12	201B121    65	2729019018	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.25083	-118.54097	Plan check for installation of roof-mounted solar PV system on SFD. Interconnect with a 225A MSP with new 200A main disconnect.  10kW ungrounded system. (26) 290W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14227	16041-10000-12526	1221 W 47TH ST	90037	9	111B197   511	5017014026	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.00075	-118.29678	PV1, INSTALL 3.06 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI -3.0-OUTD-S-US Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14228	19041-10000-42195	1422 S MAIN ST	90015	14	124-5A207 272	5133012001	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.03462	-118.26149	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14229	18041-10001-41825	1750 N GLENDALE BLVD	90026	13	144A209   317	5423005024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.20	Electrical	Electrical	Apartment			06/12/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.08713	-118.25942	"Delta ""1"" CHANGES TO AN APPROVED SET OF PLANS. TO USE ""SILENT KNIGHT"" IFP-2000"" FIRE ALARM PANEL INSTEAD OF ""MIRCOM"". <<<<<Plan chekc for a fire alarm system located in a 4-story and 70-unit apartment building with (196) fire alarm unit, (6) power supplies, and (1) fire alarm panels.>>>>>NOTE: Permit is paid under PCIS#18041-10000-41825"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14230	18041-20002-47179	10749 N FARRALONE AVE	91311	12	207B101    54	2723006031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	12/24/2018 12:00:00 AM	ADDRESS	34.26547	-118.61065	Expedite per applicat request.  Plan check for PV roof mounted system, system size: 15.12kW DC, 13.44kW with 42 AC Modules, 100A sub panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14231	17041-10000-13843	3894 S WESTERN AVE	90062	8	117B193  1357	5036009013	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.01474	-118.30874	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  4690 SQ FT. OUTDOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14232	11041-10000-20643	1030-1038 E LAKE ST BLDG 36	90291	11	111B145   346	4243003044	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.00215	-118.46028	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14233	12041-10001-06743	6957 N FIGUEROA ST	90042	14	159A229   340	5480009019	R1-1, RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Approved	07/25/2012 12:00:00 AM	ADDRESS	34.12876	-118.18798	Plan check only. Revision to approved plans. Changes consist of PV module  manufacturer type and DC wiring calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14234	13041-20000-18603	1801 W OLYMPIC BLVD	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.05046	-118.27663	Plan check for addition of ATS(s) and emergency distribution panels to existing emergency system. No new loads. City National Bank.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14235	13041-10000-17629	12895 W RUNWAY ROAD Units 1-6	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/03/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	33.9751	-118.42068	PLAN CHECK POWER AND ENERGY FOR NEW 6-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #2  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14236	19041-20000-37126	5528 N TAMPA AVE	91356	3	174B117   420	2163016013	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM			Reviewed by Supervisor	10/02/2019 12:00:00 AM	ADDRESS	34.17163	-118.55332	PV1.  Install 14.4 kW DC / 12.24 kW AC roof mounted grid tied PV system.  (45) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14237	18041-20001-15813	9540 N VASSAR AVE	91311	12	201B105   236	2746016055	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Issued	07/19/2019 12:00:00 AM	ADDRESS	34.24413	-118.60451	07-11-2019  Changes to an approved set of plan, changes include reconnect feeders to the new service equipment. All changes apply to delta 1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14238	10041-10000-08354	1301 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			05/05/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.0517	-118.2248	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14239	13041-10003-12515	819 S SANTEE ST	90014	14	126A211    46	5145013005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			07/06/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.04107	-118.25233	CHANGES TO PERMITTED SET OF PLANS; LOAD SUMMARY FOR SOME UNIT APARTMENTS USES 220.82 OF THE NEC. ALL CHANGES ARE CLOUDEDCHANGE OF USE OF AN EXISTING 93,379 SQFT, 13-STORY BUILDING W/ BASEMENT INTO JOINT LIVING AND WORK QUARTERS PER THE ADAPTIVE REUSE ORDINANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14240	16041-20000-18738	1901 W BEVERLY BLVD	90057	13	135A205    38	5157027052	C2-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.06582	-118.26799	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 18.53 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14241	18041-10001-25204	6312 W YUCCA ST	90028	13	150A187   371	5546004027	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.10361	-118.32728	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA DELTA 2. CHANGES INCLUDE REMOVING SUBPANELS ON THE SINGLE LINE DIAGRAM DUE TO SPLIT BUS PANELBOARDS, REVISING ELECRICAL ROOM LAYOUT, AND PANEL SCHEDULES. ALSO RELOCATING PANELBOARDS ON THE FLOOR PLANS.NOTE: PERMIT IS PULLED UNDER MASTER APPLICATION#18041-10000-25204	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14242	12041-10000-14951	6633 N FALLBROOK AVE	91307	3	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.19044	-118.62372	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT EXISTING RETAIL  (ANNA'S LINEN) #915. PERMIT FOR NEW BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14243	14041-20001-05149	12698 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/25/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	33.97714	-118.41552	((EXPEDITE FEES)))PC FOR SERIES OF PHOTOVOLTAIC SYSTEMS FOR NEW CONDOS. THIS SYSTEM IS SPECIFIC FOR UNIT 1. SYSTEM SIZE 3KW AC. SYSTEM IS TIED TO MAIN SERVICE SERVING OTHER UNITS. THIS IS PLAN CHECK AND PERMIT SUBMITTAL 1 OF 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14244	19041-10000-40900	9031 N LURLINE AVE	91311	3	195B109   477	2780001063	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM			PC Approved	10/09/2019 12:00:00 AM	ADDRESS	34.23463	-118.58443	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI IN AN EXISTING COMMERCIAL SPACE (AMAZON DELIVERY CENTER). SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2455 SQFT. B#19016-10000-32366	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14245	17041-10000-25680	10531 W BLOOMFIELD ST	91602	4	165B177   424	2424011014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2017 12:00:00 AM			Corrections Issued	07/28/2017 12:00:00 AM	ADDRESS	34.14972	-118.36032	PLAN CHECK FOR ROOF MOUNTED SYSTEM - SYSTEM SIZE 7.6KVA CONSISTING OF ONE INVERTER(SOLAR EDGE SE7600A-US) AND 22 MODULES(SUNWORLD SW290 MONO) AND 22 P300 POWER OPTIMIZERS	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14246	18041-20001-20603	12145 W HOLLYGLEN PL	91604	2	162B165   645	2369007007	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2018 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.13989	-118.39771	Expedite per applicant requestPlan check for PV roof mounted system. System size: 15.2kWac with 69 modules and 2 inverters(7.6kw) connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14247	14041-10000-23325	10250 W SANTA MONICA BLVD UNIT FC3	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IMPROVEMENT IN EXISTING RESTAURANTNEW LIGHTING CIRCUITPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14248	16041-10001-27070	535 N FAIRFAX AVE	90036	5	141B177  1012	5527020004	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.08104	-118.36162	SUPPLEMENTAL PC FOR T-24 ONLY FOR APPORVED SET OF PLANS UNDER 16041-10000-27070. INCREASING AMOUNT OF TRACK LIGHTING FIXTURES IN MEZANINE RETAIL AREA AND INSTALLING LUMINAIRE FIXTURE IN BATHROOM. CHANGES CLOUDED UNDER DELTA 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14249	14041-10000-27471	4900 W SUNSET BLVD ROOF	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.09786	-118.29626	ON MCCA, REMOVE and  REPLACE CH-1 AND CHP-1 AND EF UNITS IN PHASES 1 & 2; REMOVE AND REPLACE CH-2 AND CHP-2 IN PHASES 3&4. NEW CHILLERS ARE LOWER AMPERAGES; REPLACE FEEDERS WITH SAME TYPE AND SIZES..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14250	16041-10003-20627	4929 N VAN NUYS BLVD	91403	4	169-5A151  49	2263026034	C1.5-1VL-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM			PC Approved	06/15/2018 12:00:00 AM	ADDRESS	34.16026	-118.4489	"[6/15/18 CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA ""ASI-1"" CHANGES. CHANGING FUSED DISCONNECTS TO 400AMPS]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14251	18041-10000-01562	1030 N SWARTHMORE AVE #2-108	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Info Complete	01/30/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	INITIAL TENANT IMPROVEMENT TO EXISTING RETAIL SPACE IN PREPERATION FOR FUTURE TENANT BY LANDLORD. THERE IS NO LUMINAIRE INSTALLATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14252	14041-20000-11522	3245 S CASTLE HEIGHTS AVE	90034	5	123B165   784	4311003007	R1-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.03231	-118.39961	PV1. ROOF MOUNTED SOLAR SYSTEM. STANDARD TRANSFORMERLESS  CENTRAL INVERTER PLAN. SYSTEM SIZE: 6.5 KW DC(25) REC 260 MODULES(1) POWERONE 6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14253	19041-20000-05144	17437 W NAPA ST	91325	12	195B129   535	2787026050	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.22697	-118.51418	PV1.  Install 6 kW grid tied roof mounted PV system.  (14) modules with 6 kW rated string inverter.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14254	12041-20002-19302	7800 N WOODLEY AVE	91406	6	189B141   290	2206009901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	04/02/2013 12:00:00 AM	ADDRESS	34.21161	-118.48344	T-24 and emergency lighting plan check for 22000 square foot warehouse area of existing building.  Added skylights to roof of the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14255	15041-20000-28824	19411 W MARILLA ST	91324	12	201B117   282	2761008020	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.24755	-118.55617	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system.Solar clearance refference: 15041-20000-21033	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14256	19041-20000-32345	3201 S LA CIENEGA BLVD	90016	10	123B173  1581	4205035014	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.02965	-118.37211	TENANT IMPROVEMENT OF (E) OFFICE SPACE PLAN CHECK FOR TITLE 24 ONLY. TOTAL AFFECTED AREA 1,353 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14257	14041-10000-26907	13530 N ELDRIDGE AVE	91342	7	228B157   948	2511029029	C2-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM			PC Approved	09/30/2014 12:00:00 AM	ADDRESS	34.31807	-118.42451	Energy plan check for adding new lights in an food preparation area inside a market place.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14258	17041-10000-14763	1875 S CENTURY PARK EAST STE#320	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.06115	-118.41457	TI FOR OFFICE SPACE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14259	19041-10000-32435	8635 W 3RD ST 120	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	01/05/2021 12:00:00 AM		Issued	01/05/2021 12:00:00 AM	ADDRESS	34.07373	-118.38073	PC FOR POWER AND ENERGY.  SCOPE INCLUDES REPLACING X-RAY EQUIPMENT AND ADDING NEW CIRCUITS AND LIGHTS.  TOTAL AFFECTED  AREA IS 266 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14260	17041-20000-46515	20041 W NORTHRIDGE ROAD	91311	12	207B113   146	2708020017	RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.26228	-118.56963	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.173 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14261	19041-10000-12293	501 S GAFFEY ST	90731	15	015B197   243	7451030034	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM			PC Info Complete	06/14/2019 12:00:00 AM	ADDRESS	33.73954	-118.2925	PC FOR TITLE 24 ENERGY ONLY FOR RETAIL T.I.  FOR  A SINGLE STORY RITE AIDTOTAL AFFECTED AREA 17,664 SCOPE INCLUDES NEW LIGHTS, CIRCUITS, AND EUQIPMENT. B# 19016-10000-08983	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14262	11041-20000-22999	8436 W 3RD ST	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM			PC Approved	11/17/2011 12:00:00 AM	ADDRESS	34.07301	-118.37448	Existing retail space (Suite 600).  remodel of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14263	15041-20001-20430	5404 N ENCINO AVE	91316	5	174B129  1016	2257010007	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2015 12:00:00 AM			Reviewed by Supervisor	07/08/2015 12:00:00 AM	ADDRESS	34.16922	-118.51405	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6.3 kWac and consists of (25) modules, (25) micro-inverters, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14264	15041-10000-26055	124 W 4TH ST	90013	14	129A211    58	5149023011	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.04852	-118.2481	PC FOR ENERGY. T.I. NO CHANGE OF USE. TOTAL AREA 3629 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14265	15041-20000-42767	526 N SALTAIR AVE	90049	11	138B141   500	4429020007	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.07106	-118.47555	"""0$ permit fees due to senate bill 1222""PV1. Install 18.996 kW DC roof-mounted, utility-interactive PV system.  (2) SMA SB6000TL-US and (1) SMA SB7000TL-US inverters with (58) SunPower SPR-327 modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14266	15041-10000-28048	1403 W LOMITA BLVD 103	90710	15	039B193   641	7439026015		Harbor				2933.02	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	33.79798	-118.30209	"""OSHPD 3 PROJECT""TI TO AN EXISTING LOW RISE MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14267	13041-20000-26008	333 S GRAND AVE Floor 45	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	Change to lighting, receptacles.  Load is 300 amps per applicant.  Existing high-rise office building.  PLAN CHECK ONLY for Energy, with Emergency lighting.  May require full plan review subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14268	19041-10001-47663	23749 W FITZGERALD ST	91304	12	189B089    18	2020010034	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM			PC Approved	01/31/2020 12:00:00 AM	ADDRESS	34.2178	-118.64551	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTIN RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.88KWdc / 11.029KWac.(33)MODULES- LG360Q1C-A5(1)INVERTERS- SOLAREDGED SE7600H-US(1)INVERTERS- SOLAREDGE SE3800H-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14269	19041-10000-34145	22123 W BALLINGER ST	91311	12	201B101   584	2727015027	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.24338	-118.60899	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(NINGBO GINLONG SOLIS-1P6K-4G-US) WITH 22 MODULES(LG330N1C-A5) AND RAPID SHUTDOWN DEVICEMAIN PANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14270	17041-10001-43977	3415-3419 W 1ST ST	90004	13	138B197   742	5501007024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM	ADDRESS	34.07363	-118.28735	Change to approved set by modifying the lighting plan, all changes under delta-2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14271	17041-10000-17542	10250 W SANTA MONICA BLVD #1650	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for 1st time tenant ""Sandro"" #1650, total area: 1,650 sq.ft. Fed from DB ELA41"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14272	17041-20000-30139	637 S CERES AVE	90021	14	126A213   442	5147030008	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Info Complete	08/23/2017 12:00:00 AM	PIN	34.03896256	-118.24248261	Plan check for power only. New 800A 120/240V 3ph 4w service for existing commercial building.Relocate existing loads to new subpanel. Install new textile processing equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14273	12041-10000-10588	14006 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for T24 Energy/Emergency lighting for retail store unit #39B (Pottery Barn).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14274	18041-10002-42449	4950 W SUNSET BLVD	90027	13	147B197   813	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.09786	-118.29745	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REMOVAL OF DISCONNECT AT MAIN SERVICE PANEL AND REPLACING IT WITH AN OCPD AS SHOWN ON SINGLE LINE DIAGRAM. ORIGINAL PERMIT. PLAN CHECK FOR BLOOM ENERGY (300KVA) FUEL CELL SYSTEM CONNECTING TO EXISTING DISTRIBUTION EQUIPMENT - CONNECTION CONSIST OF UPGRADING 600A PANEL TO 1200A, ALL BREAKERS ARE 100% RATED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14275	11041-10000-05842	500 S CENTRAL AVE	90013	14	126A215    61	5147014005	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Finaled	05/18/2011 12:00:00 AM	ADDRESS	34.04092	-118.23969	CHANGE OF USE (13,955 SQ FT) OF EXISTING WAREHOUSE TO BEVERAGE WHOLESALE.  FULL PLAN CHECK AND T-24.  2 NEW PANELS AND TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14276	13041-10001-02996	1900 S CENTRAL AVE	90011	9	120A211    84	5129003037	C1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	34.02412	-118.25057	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 6 ON THE FLOOR PLAN.  CHANGES INCLUDE ORIENTATION OF SITE PLAN.  ALL ELECTRICAL EQUIPMENT AND CIRCUITS ARE EXISTING.New single story restaurant building. Power and Energy (indoor and outdoor) full plan check. Service size: 800A. Indoor sqrft: 5,037. Outdoor sqrft: 44,250.Variance to separate fire alarm plans filed on 12/3/2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14277	18041-10000-46331	2155 N WESTRIDGE ROAD	90049	11	138B133   335	4492014008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	02/08/2019 12:00:00 AM		Issued	02/08/2019 12:00:00 AM	ADDRESS	34.07382	-118.50352	Note: Fees are $0 due to Assembly Bill 1414.NEW ROOFTOP SOLAR SYSTEM CONSIST OF 40 MODULES (HANWHA Q-CELLS) AND 40 OPTIMIZERS (SOLAR EDGE) AND 10KW INVERTER ,  2 - 14KW ENERGY STORAGE SYSTEM.  SYSTEM SIZE IS 12.2KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14278	12041-10000-18191	21819 W ARMINTA ST	91304	3	189B105   297	2110008018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.2138	-118.60319	NEW 7.8KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14279	19041-10000-08536	2560 W OLYMPIC BLVD #100	90006	1	130-5A201 141	5076008030	(Q)C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Issued	03/14/2019 12:00:00 AM	ADDRESS	34.05219	-118.28707	Full plan check for a change of use form office to medical office. Scope includes new lighting and equipment with a total area of 1551-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14280	18041-20001-35464	12632 W SUNSET BLVD	90049	11	132B141   565	4405028017	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			Reviewed by Supervisor	09/27/2018 12:00:00 AM	ADDRESS	34.05702	-118.48405	Expedite per applicant requestPlan check for PV roof mounted system, system size: 13.96kW AC with 46 PV modules and 46 Microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14281	13041-10000-24745	15717 W HIAWATHA ST	91344	12	204B141    68	2661010010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.25926	-118.47445	PV1 4.9KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-5000-OUTD-US}]. [(20)modules: {Trina {TSM-245PC05.18}}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14282	11041-20000-16417	8340 N VAN NUYS BLVD	91402	6	192B149   292	2638022061	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.22301	-118.44856	energy plan chek retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14283	15041-10000-11197	1728 S MAPLE AVE	90015	14	123A209   299	5127021007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.03015	-118.26061	RETROFIT OF EXISTING LIGHTS TO LED WITH RETROFITS KITS. TITLE 24,  PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14284	13041-20000-17453	20740 W CAMPANIA LANE	91326	12	213B109   393	2701068004	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.27977	-118.58527	New PV rooftop system for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14285	19041-20000-01450	665 E BROOKS AVE	90291	11	111B145  1720	4239008***	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	33.99668	-118.46674	Addition of 5kWh energy storage system to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14286	18041-10000-47217	2515 W SAN FERNANDO ROAD	90065	1	150B213   512	5457008027	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.10717	-118.24026	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14287	19041-20000-53030	9808 N FARRALONE AVE	91311	12	201B101   223	2727012052	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.24851	-118.61025	PV1. INSTALL 13.32 KW DC ROOFMOUNTED PV SYSTEM WITH (36) MODULES, OPTIMIZERS AND (1) INVERTER(SE11400H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14288	15041-10000-19117	1515 W 54TH ST	90062	8	108B193   490	5003015005	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	33.99335	-118.30293	PV1 ROOF MOUNTED. 12 MODULES AND 1 INVERTER. 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14289	15041-20000-27131	1314 E ADAMS BLVD	90011	9	117A211    64	5118011017	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.0162	-118.2497	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14290	12041-10000-15732	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK FOR INSTALLATION OF NEW EMERGENCY FUEL SHUT OFF SYSTEM AT BRADLEY EAST GATES. WIRING IN HAZARDOUS AREA.FIRST EXTENSION TO EXTEND PLAN CHECK FILED 8/1/2014.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14291	13041-10000-31537	7242 N EASTHAVEN LANE	91307	12	186B089   699	2027022027	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.20278	-118.6477	PV1, Install 4.75 kW DC roof-mounted solar array for a 2-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 19 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14292	18041-10000-20642	4935 N BALBOA BLVD	91316	5	168B133    61	2258018900	[Q]PF-1XL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.1604	-118.50137	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR ENCINO COMMUNITY CENTER. ASSEMBLY OCCUPANCY . 4269 SQFT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14293	16041-10002-04633	1522 W LOMITA BLVD	90710	15	036B193    60	7410002085	[Q]R3-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Apartment			02/07/2018 12:00:00 AM			Reviewed by Supervisor	02/16/2018 12:00:00 AM	ADDRESS	33.79764	-118.30346	PC  FOR  LOST SET OF PLANS THAT WERE PREVIOSUY APPROVED. FULL PC FOR A NEW 2-STORY 14 UNITS APARTMENT BUILDING OVER 1 LEVEL PARKING GARAGE. NEW 120/240V 1 PHASE, 3 WIRE 800A SERVICE. TOTAL SQ. FT. 14329	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14294	13041-10000-33020	12237 N CRYSTAL HILLS WAY	91326	12	219A117   136	2701013028	RD3-1, RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch		1082.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Expired	02/11/2016 12:00:00 AM	ADDRESS	34.29569	-118.56257	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 6 KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(24) TRINA SOLAR # TSM-250(24) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE6000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14295	13041-20000-27372	1100 S GLENDON AVE	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	10/02/2013 12:00:00 AM	ADDRESS	34.06074	-118.44418	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. NEW LIGHTING. TOTAL 935 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14296	18041-20000-31331	21625 W CALIFA ST	91367	3	177B105    96	2146006033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.17741	-118.60056	Installation of (20) EV charging stations in (E) commercial parking garage supplied by new 150 kVA transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14297	13041-20000-17143	24425 W CALVERT ST	91367	3	177B089   851	2032011074	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.18297	-118.65673	PLAN CHECK FOR SERVICE UPGRADE FROM 400A TO 800A. UPGRADING EXISTING SWITCHBOARDS. RUNNING CONDUIT FOR FUTURE EXPANSION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14298	15041-20000-01729	19400 W CRYSTAL RIDGE LANE	91326	12	219A119   116	2701007022	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.29496	-118.55675	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14299	13041-20000-07843	16513 W CALAHAN ST	91343	12	198B137   847	2676020020	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.23676	-118.49199	Enphase system on roof of single family dwelling.  The circuit wiring shall be run in the insulated attic space from the jbox and shall poke out under the eves and down the wall to the meter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14300	14041-10000-09889	325 S AVENUE 17	90031	1	136-5A219 144	5447028008	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.06846	-118.22202	Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14301	17041-20000-34979	10100 W SANTA MONICA BLVD Ste 1075	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI to (E) commercial high-rise office space.  Plan check for energy.  970 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14302	13041-10000-34616	22254 W SCHOOLCRAFT ST	91303	3	183B101   569	2024034008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	34.19591	-118.61206	PV1 4.968KWAC. 240V. microinverter. STD. 1story. Roofmount. [(23) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(23)modules: {LG 260SIC-G3}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14303	15041-10001-41035	4042 W DON LUIS DR	90008	8	114B181   500	5026003007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM			PC Approved	02/12/2016 12:00:00 AM	ADDRESS	34.00704	-118.34302	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 3.0KWac. (12)MODULES-KYCOERA #KU2656ZPA(1)INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-ASCOPE INCLUDES REDUCING NUMBER OF MODULES FROM 15 TO 12 MODULES UNDER PAID PERMIT.NOTE: PERMIT PAID UNDER PCIS#15041-90000-41035(((allation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14304	10041-20001-11125	6100 W MELROSE AVE	90004	4	141B185   595	5523001017	C2-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	PIN	34.08320613	-118.33343965	Plan check for revision to T-24 Energy calculation and lighting layout. Plan check now includes outdoor lighting. Additional permit includes new ckts for outdoor lighting and dedicated panel for track lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14305	15041-10000-25863	2138 N MICHELTORENA ST	90039	4	147A205    32	5432022008	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	09/02/2017 12:00:00 AM	ADDRESS	34.0991	-118.26949	PC FOR POWER, NEW 600 AMP SERVICE FOR A RESIDENTIAL HOME AND GUEST HOUSE. 5 PANELS 120/240 SINGLE PHASE, 3W. TOTAL SQ. FT. 5674.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14306	18041-10001-17755	10351 W SANTA MONICA BLVD 406	90025	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Issued	06/13/2018 12:00:00 AM	ADDRESS	34.05844	-118.42319	Design build. Energy plan check for an office T.I located in the 4th floor of a 4-story building, Scope includes new lighting and equipment. Total Title-24 cover 2590-SQ FT.  portion of the fee is paid under  application number 18041-90000-17755.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14307	16041-10000-04051	330 W OLYMPIC BLVD	90015	9	127-5A209 252	5139012013	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.04204	-118.2594	New Restaurant 600A MS. PC for Power and Energy (Build App. 08016-10000-09013). T-24 per 2008 CodeTotal area: 9584 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14308	16041-20001-38089	23800 W LADRILLO ST	91367	3	171B093   649	2047012014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM			PC Approved	10/29/2016 12:00:00 AM	ADDRESS	34.16302	-118.6438	Expedited plan check fee per applicant request.  PV1.  Install 9.28 kW DC roof mounted grid-tied PV system.  (29) modules with (1) 7.6 kW-rated inverter with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14309	13041-20001-22720	6537 W 84TH PL	90045	11	096B165   154	4108013008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	33.96216	-118.40293	((expedite fees))pv1 single family dwelling. total system size 3.8 kw using 12 modules. system uses power optimizers. nonstandard plan transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14310	13041-10000-24134	5760 W ARBOR VITAE ST	90045	11	093B169    79	4125020014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	33.9525	-118.38238	$0 permit fee per Senate Bill 1222PV3. NEUTROGENA MANUFCATORING PLANT. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 233.240 KW DC. 225KW INVERTER. 952 MODULES.  1 OF 2 BUILDINGS ( DIFFERENT ADDRESSES)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14311	17041-10000-23822	820 W COLDEN AVE	90044	8	093A199   129	6054001009	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Closed	12/07/2018 12:00:00 AM	ADDRESS	33.94893	-118.29021	New fire alarm system for a 3-story 39 unit apartment ; Scope include (1) fire alarm panel, (1) power supply and (66) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14312	12041-10001-10792	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM	12/17/2012 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.03396	-118.24117	((((10-11-12  changes made to previously approved , feeders , panels, xfrms, clouded, one fixture deleted from title 24.)))))  CORE RENOVATION IN AN EXISTING 4 STORY BUILDING.  CORE & SHELL. EXISTING MAIN SERVIOCE @ 4.8KV FEEDING A NEW 4800 VOLT, 1.5MVA SUBSTATION. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14313	14041-20000-01212	333 S GRAND AVE 8th floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	Change to lighting and loads on the 8th floor of an existing high-rise office space.  This job has 390 amps of new load per applicant.  The Engineer has split the project into multiple separate plan checks less than 400 amps of load.  FULL PLAN CHECK MAY REQUIRED FOR ALL PARTS OF THE PROJECT SUBJECT TO FIELD INPSECTOR REQUEST.  Plan check only for Energy, with Emergency lighting.  ((Permit fees are under INSPECTION)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14314	14041-10000-15477	633 W 5TH ST SUITE 3200	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.05099	-118.25468	Title 24 plan check only for existing highrise.  Total area = 9,067 sq. ft.Provide new power circuits.  Existing pannel boards.  New lighting in the area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14315	15041-10000-39480	1249 S GRAND AVE 1-115	90015	14	126A207   160	5139022018	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.03937	-118.2645	INSTALLING NEW FIRE SYSTEM  391 FA DEVICES + ONE FA PANEL +ONE COMMUNICATION PANEL + 3 CONTROL PANEL. 126 UNIT, 7 S-STORY APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14316	12041-10000-23552	505 S FLOWER ST	90071	9	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.0515	-118.25654	Replace Emergency generator with a new 1000 kw generator for emergency lights and elevator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14317	13041-10000-35242	444 S FLOWER ST STE# 3675	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	T24 PART 6 ENERGY PLAN CHECK FOR (E) OFFICE SPACE OF APPROX. 2351 SQ FT OF AREA. HIGH-RISE BUILDING; EMERGENCY LIGHTING WILL BE FED VIA (E) EMERGENCY CKT. SCOPE OF WORK < 400A. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14318	18041-20001-00596	16111 W MEADOW VIEW DR	91436	5	165B141   561	2285014033	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			Reviewed by Supervisor	01/19/2018 12:00:00 AM	ADDRESS	34.15014	-118.48406	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.84	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14319	16041-20001-15745	5242 W ADAMS BLVD	90016	10	123B177  1006	5043004036	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.03227	-118.35703	7/14/17changes to an approved set of plans.  changes include updating AIC ratings to reflect DWP fault current level.  changes to lighting fixtures and energy calculations to reflect field conditions.  this is plan check only.    (((Plan check for new 3 story office building. Service size: 1,200A. Total area: 14,381 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14320	17041-20000-26316	6129 N ST CLAIR AVE	91606	2	177B165   419	2333006017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.18205	-118.39994	Plan check for solar pv system, roof-mounted on SFD.11.52kW ungrounded system. (36) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14321	12041-10001-18251	3967 N FREDONIA DR	90068	4	159B177    71	2380002012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2012 12:00:00 AM			Reviewed by Supervisor	09/17/2012 12:00:00 AM	ADDRESS	34.13558	-118.36551	SUPLUMENTAL TO A 5.4 KW ROOF MOUNTED PV SYSTEM. USING X-FORMERLESS INV, ADDING POWER OPTIMIZER. CHANGE FROM STANDARD PLAN TO REGULAR. PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14322	18041-10000-38756	1300 W STORM PKWY	90501	15	045B197    74	7347018098	M2-1VL, M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.81677	-118.29921	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14323	13041-10000-16878	925 W SUPERBA AVE	90291	11	108B149   179	4241018021	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2013 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	33.99533	-118.45846	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE FAMILY DWELLING. SYSTEM SIZE IS 3.24 KW. USING MICROINVERTER STANDARD PLAN WITH 15 MODULES AND 15 MICROINVERTERS. [MODULES: SOLAR WORLD # SW 260 MONO |||| INVERTERS: M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14324	13041-10000-15885	4970 N CASA DR	91356	3	168B121    31	2176008005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Expired	07/22/2015 12:00:00 AM	ADDRESS	34.16045	-118.54855	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. SYSTEM SIZE IS 7.84 KW USING 32 MODULES AND TWO INVERTERS. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: SOLAREDGE # SE3800A-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14325	19041-10000-31823	4142 W ROSEWOOD AVE	90004	13	141B197  1123	5520017027	R4-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0789	-118.29475	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14326	19041-10000-03107	1060 W 20TH ST	90731	15	012B193  1029	7462012075	R2-1XL	Harbor	San Pedro	Coastal San Pedro		2972.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	33.72621	-118.3004	Plan check for a PV1 7.6kw AC / 8.64kw DC roofmounted system with (27) modules and (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14327	12041-10000-05160	5555 W MELROSE AVE BALL BLDG-# 146	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM			PC Approved	03/07/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	600 SQUARE FEET OF TENANT IMPROVEMENT WORK ON THE GROUND FLOOR ONLY, WITHIN AN EXISTING 3 STORY OFFICE BUILDINIG, TO CREATE A FULLY ACCESSIBLE ENTRANCE WITH NEW STAIRS, A NEW HANDICAPPED LIFT, NEW CEILINGS WITH SOME STRUCTURALPLAN CHK IS FOR TITLE 24 (INTERIOR AND EXTERIOR NEARBY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14328	13041-10001-13369	380 WORLD WAY 4th Floor	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	This plan approval is for misplaced approved set, no change exceept for reading meter ( meter reading used is DWP meter reading.  No need for 30 day demand) to be pulled under inspection fees.>>>>>>>>>PLAN CHECK FOR POWER AND ENERGY. FIRST TIME TENANT OF TSA OFFICE ON THE 4TH FLOOR OF TOM BRADLEY INTERNATIONAL AIRPORT.  EXISTING CORE AND SHELL.***ADDITIONAL FEES ON SUBMITTAL 2Fees are paidVariance was filed for the 30 day reading--NM ( No need for variance, DWP meter used for load calculations)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14329	14041-20000-17130	10526 W DUBNOFF WAY BLDG H	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM			Reviewed by Supervisor	12/11/2015 12:00:00 AM	ADDRESS	34.18656	-118.36106	"T.I. for classrooms in Building H.  Install branch circuits and lighting.  Plan check for power and energy.Note: Applicant will submit approved plans within 3 days.  See ""Application Comment"" for more info"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14330	10041-20001-16644	12304 W SANTA MONICA BLVD	90025	11	126B145   865	4267031001	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM			PC Approved	12/13/2010 12:00:00 AM	ADDRESS	34.03925	-118.46584	Revision to approved plan check. Revision to power system voltage 480/277V and change main breaker 600A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14331	16041-20001-23236	320 S LINCOLN BLVD	90291	11	111B145   656	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM			PC Info Complete	11/14/2016 12:00:00 AM	ADDRESS	34.00107	-118.46691	11/14/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Revisions have been made to lighting and power layout. *****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.  FIRST TIME TENANT. RESTAURANT.  CAVA GRILL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14332	14041-10000-23779	7855 N VAN NUYS BLVD	91402	6	189B149   493	2210022011	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	34.21362	-118.44897	pc for energy only. less than 400A . NEW COMMERCIAL BUILDING (1-STORY 2,055 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14333	15041-10001-14954	1547 N TOWER GROVE DR	90210	5	147B157   241	4356015022	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM			Reviewed by Supervisor	06/04/2015 12:00:00 AM	ADDRESS	34.09849	-118.42597	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1 INSTALL 11.96 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (46) MODULES: KYOCERA  KU2606XPA(3) INVERTER: PVI-3.6-PUTD-S-US-Z-A & 3.0-OUTD-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14334	17041-10000-35257	707 W WILSHIRE BLVD STE 1550	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	PC FOR OFFICE TI ON THE 15TH FLOOR. SCOPE INCLUDES NEW CIRCUITS LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA (6,065 SF).B# 17016-10000-28749	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14335	13041-10001-27127	9960 N HAYVENHURST AVE	91343	12	204B137   987	2678026018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.25188	-118.49347	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14336	11041-10000-09386	4650 W SUNSET BLVD	90027	13	147B197   720	5542016030	C2-CSA1	Central	Hollywood	East Hollywood		1913.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.09787	-118.29063	TI TO AN EXISTING OFFICE BUILDING FOR CHILDREN'S HOSPITAL.    NEW PANELS, LOADS, AND LIGHTING CHANGES.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14337	17041-20000-20928	3575 N CAHUENGA BLVD W	90068	4	159B177   196	2425008023	C2-1VL, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	PIN	34.13362778	-118.35843173	PV2. ROOMFOUNTED SOLAR SYSTEM. SYSTEM SIZE: 147 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14338	19041-20000-22491	10350 W WYTON DR	90024	5	138B157    54	4359013002	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	08/01/2019 12:00:00 AM	ADDRESS	34.07521	-118.43091	New 2-story single family dwelling with 800A 240/120V 1ph-3w service.  Plan check for power. Plan check only Electrical permit cover under Building Combination permit 12010-20000-00664	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14339	19041-20000-26911	1056 S LA CIENEGA BLVD	90035	5	132B173   581	5087001042	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Apartment			08/23/2019 12:00:00 AM			PC Info Complete	12/04/2019 12:00:00 AM	ADDRESS	34.0578	-118.37598	PLAN CHECK FOR POWER AND ENERGY. NEW 2000A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14340	19041-10000-34085	20720 W SUPERIOR ST	91311	12	201B109   233	2748003089	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.24625	-118.585	REPLACE INDOOR AND OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14341	14041-10000-34536	448 W 1ST ST	90731	15	018B201   656	7449022010	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	33.7434	-118.28673	PV1.  Install 6.1 kW DC roof-mounted, utility-interactive PV system.  Transformerless inverter with (24) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14342	17041-10000-01596	10635 W SANTA MONICA BLVD 300, 305	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.05353	-118.43031	PC for energy only for office space for 2093 sqft. Adding new  lights exceeding 10% of installed lighting for enclosed office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14343	12041-20001-28950	5454 S CENTINELA AVE	90230	11	105B161   826	4220012021	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	PIN	33.98308742	-118.41076608	Modification to remove the 600amp main breaker only.                  <<<<<Install new 600 ampere service to supply new and existing panels.  Plan check for power only.  Scope of work is to install new panels and new circuits and some existing circuits.  T-24 lighting  was approved on application numbers : 12041-20000-12142, 12041-20000-23816.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14344	15041-20000-11231	4451 N STERN AVE	91423	4	165B153   130	2271011018	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Expired	05/10/2017 12:00:00 AM	ADDRESS	34.15177	-118.43563	PV1. Standard plan for SFD. Install roof mounted PV system sized 4.2 kW. Interconnected with main service panel. (14) Sunpower 327 NE Modules(1) PVI-4.2 TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14345	13041-20001-33871	3361 S MCLAUGHLIN AVE	90066	11	117B153   551	4249008017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.01742	-118.43264	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6 KWAC. 26 MODULES AND 2 INVERTERS. SUBMITTED PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14346	19041-20000-08223	5711 E MONTE VISTA ST pv1	90042	1	153A229   350	5484021002	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.10	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.11211	-118.19404	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14347	19041-10000-48134	2456 W PICO BLVD	90006	1	129B197  1090	5056001059	C2-2D-CPIO	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM			PC Info Complete	11/21/2019 12:00:00 AM	ADDRESS	34.04708	-118.29067	PC FOR T24 ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LGHTING CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 681 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14348	18041-10001-42370	10100 N MELVIN AVE	91324	12	204B117   443	2726010007	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM			PC Approved	11/14/2018 12:00:00 AM	ADDRESS	34.25391	-118.5603	Expedite per applican request(((Plan check for a PV1 11.4kw AC /13.42 DC roof mounted system with (1) 11.4KW inverter, (44) modules and optimizer inter connecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14349	17041-10000-12554	13274 W FIJI WAY #350	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.97902	-118.43558	Title 24 plan check.  T.I. to existing lowrise commercial office space.  New lighting and receptacles.  Total area = 1,402 sq. ft.     Building permit #17041-10000-09452	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14350	16041-30000-03768	1319 N MARTEL AVE	90046	4	144B181    48	5550020031	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.09499	-118.35087	Installation of fire alarm system in new 23 unit apartment building.  Total system size = 96 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14351	16041-10000-37503	5701 N FIGUEROA ST	90042	1	151-5A229 192	5492001012	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.10976	-118.19282	Plan check for energy only. Title 24 compliance check to an existing retail space. Adding new lighting and power. Total sqft = 2070.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14352	17041-20000-33491	23950 W SCHOENBORN ST	91304	12	192B089   145	2017037013	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.22089	-118.64882	Plan check for solar pv system, roof-mounted array on SFD.6.6kW ungrounded system. Interconnecting with 400A MSP.(26) 305W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14353	18041-10000-35108	11430 N LAUREL CANYON BLVD	91340	7	213B149   586	2613018030	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Issued	09/14/2018 12:00:00 AM	ADDRESS	34.27782	-118.45208	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14354	15041-20000-15397	1331 E 7TH ST	90021	14	124-5A215  32	5147035002	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			05/20/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.0363	-118.24023	Fire alarm for 87 unit apartment. 1 FACP, 10 POWER SUPPLIES AND 266 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14355	18041-10000-16259	695 S SANTA FE AVE	90021	14	124-5A2171363	5164019026	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.03508	-118.23039	Supplemental changes to approved set. Changing fire pump rating, adding ev chargers and changing circuit wiring. All changes clouded under delta E and delta RFI 88.PLAN CHECK ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14356	19041-20001-16327	10390 W SANTA MONICA BLVD	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.05734	-118.42365	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGES MADE TO T24, PANEL SCHEDULE, LIGHT FIXTURE SCHEDULE, SINGLE LINE, POWER/LIGHTING FLOOR PLANS, AND PHOTOMETRICS. CLOUDED DELTA 3, 6, AND 8 CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14357	19041-20000-04642	12300 W 1ST HELENA DR pv1	90049	11	129B141   246	4405039011	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.0519	-118.47793	PV1.  Install roof mounted PV system sized 18.3 kW AC interconnected with MSP.  $0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14358	13041-10000-13344	17400 W VICTORY BLVD	91316	12	177B129     8	2229033900	A2-1, OS-1XL	South Valley	Reseda - West Van Nuys	Encino, Lake Balboa		1320.00	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	PIN	34.18562092	-118.5132614	ADDING ANN PANEL, FACP PANEL AND 1 SMOKE DETECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14359	15041-20000-01871	3351 S HALDERMAN ST	90066	11	114B149   304	4247013010	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.0103	-118.44734	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 5.0KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14360	16041-20002-10777	11109 N SEPULVEDA BLVD	91345	7	210B145   124	2664007011	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.27256	-118.46785	Changes to approved set.  Detail added showing concrete encasement of overhead service routed along roof.  Changes clouded with delta 9.  Only sheet E0.2 affected.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14361	18041-10000-12317	10250 W SANTA MONICA BLVD Delta-40	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM			PC Approved	04/05/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"[This is plan check only, no additional permit is needed]  New revision to approved landlord's plan, noted as Delta-40.  Scope includes:   (1) Revise load calculation (connected and demand) for  DB-ELA40 and DB-ELA41. (2) Incorporate tenant's load ""Del Frisco restaurant"" into DB-ELA40 load calculation.   (3) Submit 30-Day demand load meter reading for DB-ELA40 and DB-ELA41"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14362	14041-20000-02833	7931 N OSO AVE	91306	3	189B113   613	2107025047	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.21468	-118.57553	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14363	10041-10000-17353	5390 W WASHINGTON BLVD	90016	10	126B177  1285	5063025024	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM			PC Info Complete	09/01/2010 12:00:00 AM	ADDRESS	34.03895	-118.36019	TI IN AN EXISTING MARKET. PLAN CHECK FOR T24 AND EMERGENCY LIGHTS. (PERMIT WAS PULLED # 10041-9000-16260)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14364	18041-20000-13877	7240 N HAYVENHURST PL	91406	6	186B137   239	2205010905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.20231	-118.49217	Plan check for a fire alarm system for an existing commercial building. Scope of work is the replacement of the FACP and the addition of (67) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14365	10041-10000-03910	9027 N CANOGA AVE	91304	12	195B105    39	2779018036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.23429	-118.59779	single story fire alarm monitering system. one panel, one annunciator and 5 devices .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14366	19041-10000-35799	4641 N CARITINA DR	91356	3	168B117   474	2178015005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Issued	09/13/2019 12:00:00 AM	ADDRESS	34.15457	-118.55667	$0.00 FEE DUE TO SENATE BILL 1222 AND 1414[E-Plan]CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF EQUIPMENT INSIDE GARAGE UNDER DELATA C ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14367	17041-20002-01594	5365 N VANALDEN AVE	91356	3	171B121   618	2163011028	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM			PC Approved	10/05/2017 12:00:00 AM	ADDRESS	34.16865	-118.55032	REPLANCHECK DUE TO LOST PLANS. PLANCHECK ONLY. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.24 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14368	17041-20000-00245	515 S FLOWER ST 34th Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 only. Project site is the 34th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 21,374 sq. ft.Note: Building application has been generated under 16016-10000-30932	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14369	18041-10000-16846	16141 W COVELLO ST	91406	6	186B141   130	2205021008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.20763	-118.48504	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14370	15041-20001-21587	5327 N HERMITAGE AVE	91607	2	171B165   215	2347025013	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			05/16/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.16757	-118.40046	5/16/17changes to an approved set of plans.  changes noted delta 1.  changes include new distribution board, panels and ocpd for each unit.(((((Plan check for power and energy. Project scope is a new 4-story, 42-unit apartment building. Work includes a new 1600-amp service, (54) panels, and associated loads. Fire alarm variance has been filed.Building permit found under application number 15042-20000-13720.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14371	15041-20000-36488	735 S FIGUEROA ST #120	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.04878	-118.26079	Plan check for Title 24 only. Project site is an existing commercial tenant space within a mall. Project scope is a tenant improvement. Total lighting area = 820 sq. ft.Note: Building application has been created under 15016-10000-23407	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14372	13041-20000-23386	13350 W SHERMAN WAY	91605	2	183B157    86	2328025026	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.20101	-118.42426	New 800 ampere service for existing shell building.  Site lighting is installed, plan check for T-24 lighting and for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14373	14041-20000-26778	325 N GOODHOPE AVE	90732	15	018B189    71	7559009002	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	33.74654	-118.31626	Solar clearance under permit application #14041-20000-26084. [PV1 SFD. THIS IS AN ADDITION TO EXISTING PV STSTEM. ADDITION CONSIST OF NEW 4.2KW AC RATED SYSTEM. TRANSFORMERLESS INVERTER. NONTANDARD PLAN. NEW SOLAR COMBINER. 16 NEW PV MODULES]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14374	16041-10000-38166	6334 W ARIZONA PL	90045	11	102B165    44	4110013006	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	33.97934	-118.39757	Plan check for fire alarm system in commercial space. Total  (72) devices, (1) Fire alarm panel, (2) power supplies, and (1) communication panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14375	15041-10000-27913	8837 W PICO BLVD	90035	5	132B169   830	4332014015	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.0551	-118.38454	PC FOR ENERGY. T.I FOR RESTURANT CHANGE OF SUSHI RESTURANT TO ITALIAN RESTURANT. TOTAL AREA 1981 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14376	15041-20000-27239	6600 N TOPANGA CANYON BLVD 1014	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Title 24 plan check only.  Total area = 5,036 sq. ft.  Remodel of existing sales floor and fitting room areas.  Less than 200 A new load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14377	18041-20000-40784	19948 W LULL ST	91306	3	186B113   147	2106006024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.20914	-118.56834	PV1.  Install 10.15 kW roof mounted grid tied PV system.  (35) modules and 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14378	17041-20000-29099	9516 N ORION AVE	91343	7	198B145    24	2656012025	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Re-Activate Permit	10/29/2018 12:00:00 AM	ADDRESS	34.24325	-118.47176	Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (2) inverters, (45) modules, and (1) load center.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14379	14041-20000-14706	9201 N SUNLAND BLVD	91352	6	198B173   106	2408004011	QM1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Issued	07/15/2014 12:00:00 AM	ADDRESS	34.23594	-118.36764	TI for title 24 plan check only on an existing commercial  building with 7180 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14380	17041-20001-31571	4801 N WINNETKA AVE	91364	3	168B113   263	2175027038	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.15705	-118.57061	Expedited plan check fee.PV1.  Install 7.475 kW roof mounted grid tied PV system.  (23) modules with (1) 6 kW rated SolarEdge central inverter.  Tesla PowerWall energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14381	14041-20000-21165	14207 W BESSEMER ST	91401	6	177B153   718	2240024013	M2-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.18092	-118.44244	NEW 600AMP SERVICE IN A COMMERCIAL BUILDING ONE STORY.  PLAN CHECK FOR POWER ONLY.  INSTALL TWO 200AMP PANELS WITH NO LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14382	18041-20000-12981	7265 W MELROSE AVE	90046	5	141B181   541	5525012013	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM			PC Info Complete	04/10/2018 12:00:00 AM	ADDRESS	34.08365	-118.348	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14383	15041-20001-19613	2867 W SUNSET PL	90005	10	133-5A201  80	5077013039	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Apartment			12/01/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.0609	-118.2861	12.1.2017 - Plan check for changes to approved set. Adding panel HPA1. Adding house loads. Relocating house loads and panels. New 40HP fire pump. Changes clouded delta D.======Full plan check for a new 6-story , 60-unit apartment building over a 2-level underground parking located in METHANE ZONE . Total 19-typical units. Main scope includes a 1600-Amp 3-phase 120/208V service equipment for the whole new building. T-24 area is 42228-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14384	14041-10002-30557	1099 S GRAND AVE	90015	14	127-5A207 265	5139008001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Closed	09/18/2015 12:00:00 AM	ADDRESS	34.04179	-118.26214	Modifications to approved set.  Changes to match site conditions (add'l XFMR and disconnect switches).  (((Temp power for existing building renovation.  Plan check for power.  Initial permit filed under 14041-10000-28931.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14385	19041-10000-52349	5750 W WILSHIRE BLVD 5TH FLOOR	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Info Complete	03/03/2020 12:00:00 AM	ADDRESS	34.06227	-118.3542	PLAN CHECK FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD 337AMP. ADDING NEW ELECTRICAL EQUIPMENT. TOTAL AFFECTED AREA: 31,263 SFT.(Complete Plan Check may be required, subject to field inspection.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14386	19041-20002-34226	4309 N IRVINE AVE	91604	2	165B169   570	2365024017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.14766	-118.38569	Revisions to approved set.  Relocation of equipment.  $0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.(((PV1.  Install 9.45 kW roof mounted and grid tied PV system and 13.5 kWh energy storage system.  (30) modules with 7.6 kW rated inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14387	11041-10000-26143	2585 W OLYMPIC BLVD	90006	1	129B197   208	5076004011	C2-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.05258	-118.28726	Existing restaurant to annex an existing office space on the second floor.  New 800A service and 5 new sub-panels.  Plan check for POWER and ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14388	13041-10000-01199	20350 W PLUMMER ST	91311	12	198B113    77	2748022800	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.24257	-118.57729	T24 FOR PARKING LOT CANOPY.  EXISTING BRANCH CIRCUIT, NEW LIGHTING FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14389	16041-20000-31607	12220 W CANTURA ST	91604	2	162B165   376	2369005027	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	10/01/2016 12:00:00 AM	ADDRESS	34.14216	-118.39954	Plan check for roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 150A.8kW ungrounded system (8+3). (36) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14390	14041-10000-02947	3424 W WILSHIRE BLVD #600	90010	10	132B197    49	5094006015	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.06159	-118.2982	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SUITE #600 ON 6TH FLOOR . OFFICE TI. 10560 SQFT, EMERGENCY LIGHTING. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14391	19041-20000-12415	8000 W SUNSET BLVD ev3	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Issued	04/18/2019 12:00:00 AM	ADDRESS	34.09783	-118.36466	addition of 600 amps board to feed EV chargers tied into an existing 1200 amps distribution board. plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14392	14041-20000-33983	22523 W SCHOOLCRAFT ST	91307	12	183B101   515	2024026024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.19621	-118.61757	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.Derating the main from 200A to 150A.System size: 8.6kW (inv1 - 5; inv2 - 3.6). Ungrounded system.44  255W pv modules across 5 strings (inv1 - 12 and 7+7 combined; inv2 - 8+10).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14393	17041-10002-44137	8352 N CANTALOUPE AVE	91402	6	192B153   625	2637030022	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.22301	-118.43567	03-02-2018 Changes to an approved set of plan. Changes include addition on AC disconnect and sub panel. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14394	13041-10001-33051	7516 W 83RD ST	90293	11	096B157   375	4114026014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	33.96122	-118.42888	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14395	14041-10000-11404	10700 W SANTA MONICA BLVD #305	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	Plan check for power and energyT.I. for first time occupant in 3rd floor (dental office)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14396	12041-10000-11718	2121 E 7TH PL	90021	14	124-5A217 295	5166002022	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	05/22/2012 12:00:00 AM	ADDRESS	34.03368	-118.22913	Tenant improvement. Plan check for energy and emergency lighting. 3480 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14397	13041-10001-27885	11809 W ROSE AVE	90066	11	117B153   416	4250003002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.01806	-118.43674	][][EXPEDITED PER APPLICANT REQUEST ][][]PV1, 6.76KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(26)modules: {Suniva {#OPT260-60-4-100}}] with optimizers: [SOLAREDGE {POWERBOX 300W OP300-MV-TYCRM-2NA}. (E) 200A MAIN. THE 300W OPTIMIZERS WILL BE CHARGED UNDER NON-DWELLING POWER EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14398	14041-20001-03110	5716 N BUCKNELL AVE	91607	2	174B169   505	2339006023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.17437	-118.3901	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14399	12041-20000-19281	4520 N VAN NUYS BLVD	91403	4	168A151   188	2265013025	C2-1VL, P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM			PC Approved	08/16/2012 12:00:00 AM	ADDRESS	34.15371	-118.4485	Install new outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14400	19041-10000-25584	7747 W FOOTHILL BLVD	91042	7	204B193   405	2558003900	OS-1XL, PF-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1011.10	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	34.25777	-118.30108	Full plan check per applicant request. Scope includes remodeling new lighting, and equipment located inside a  Municipal Office Building with a total lighting aarea is 7871-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14401	16041-20000-34075	9601 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.24501	-118.59876	TI to an existing single-story commercial building/food production facility.  Addition of new equipment to existing service boards.  Newly connectd load >400 amps - plan check for power and energy.  Total square feet:  17296 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14402	10041-10000-22594	11661 N GLENOAKS BLVD	91331	7	213B157   303	2524022011	C2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Apartment			01/07/2011 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.28155	-118.42034	upgrade service to 600A; CHANGE  PANELS IN 2 EA UNITS AND HOUSE PANELS;NEW CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14403	19041-10000-50343	3057 W PICO BLVD	90006	10	129B193  1247	5080012033	(T)(Q)RAS4-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	04/24/2023 12:00:00 AM	ADDRESS	34.04734	-118.30781	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL WITH 273 DEVICES AND 9 POWER SUPPLIES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14404	18041-10000-02114	6060 W CENTER DR	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	33.97602	-118.39073	PC for T24 only for new lighting in lobby area of office space and outdoor hardscape. Installing new lights and receptacles. Total area is 13353sqft. B# 17016-10000-36281.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14405	13041-10001-32255	8427 W HILLROSE ST	91040	7	207B189   651	2555004028	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.26351	-118.3168	Expedited RSES plan check per applicant request.PV1, Install 7.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE6000A-US. 29 modules TRINA SOLAR TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14406	15041-20002-09722	1418 N NORTH SPRING ST	90012	1	136-5A217  75	5409004002	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.06685	-118.23206	01/13/2016 Changes to an approved set of plans. Plan check is for Delta 1 only. Changes have been made to the outdoor lighting; outdoor lighting changes have been reflected on Title 24 sheets. UGPS has been added to single line diagram to reflect field installation, per LADWP methane requirement.*****Previous Work Description*****Plan check for power and energy. Total outdoor lighting area = 16,225 sq. ft. Service upgrade to existing commercial building. Interior tenant improvement shall be done under a separate permit. Completely new electrical distribution system with 1600 A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14407	12041-10000-08340	14630 W PLUMMER ST	91402	7	198B149    69	2650026900	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.2424	-118.45147	PLAN CHECK POWER AND ENERGY FOR NEW TWO STORY LAFD FIRE STATION. NEW 800 A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14408	18041-10000-15668	21820 W BURBANK BLVD SUITE 330	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.17228	-118.6032	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR OFFICE .14127 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14409	11041-20000-16194	1250 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/02/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Expired	09/10/2013 12:00:00 AM	ADDRESS	34.02528	-118.29315	New 9.67 KW PV System for Apartment Bldg #1250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14410	19041-20000-18614	15260 W VENTURA BLVD 2nd Floor	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check for Title 24 only. Project site is the common areas of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,831 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14411	10041-20000-14653	11100 W SANTA MONICA BLVD	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	10/15/2010 12:00:00 AM	ADDRESS	34.04726	-118.44465	Tenant space lighting on 5th floor. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14412	10041-20000-06004	15840 W MONTE ST B-109	91342	7	225B141  1523	2604003036	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	04/02/2010 12:00:00 AM		Permit Finaled	06/15/2010 12:00:00 AM	ADDRESS	34.31015	-118.47604	OFFICE T.I.ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14413	19041-10000-26908	2334 N FLETCHER DR	90039	13	150A209   194	5438015056	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	09/18/2020 12:00:00 AM	ADDRESS	34.10479	-118.25818	POWER PLAN CHECK TO REPLACE & RELOCATE 800A 120/240V SERVICE EQUIPMENT DUE TO FIRE DAMAGE. SCOPE INCLUDES NEW HOUSE PANEL.  Comply with department order effective date 6/13/2019,  permit will expire 30 days from issuance date.B#19016-20000-20638	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14414	16041-10002-14571	1616 W 209TH ST #1	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	33.84074	-118.3073	07/13/16Changes to an approved set of plans. Changes include adding a 20A fuse to the 30A AC disconnect, upgrading the 125A subpanel to 200A, and replacing the main service panel from 100A to a New 400A 4 bank meter stack. Note: Permit is pulled under PCIS#16041-10000-14571((((06/14/16Changes to an approved set of plans. Changes include reducing the number of modules on the roof from 10 to 7 modules, and replacing the inverter from a solaredge #SE3000a-us to an ABB# pvi-3.0-outd-sz-a.  All changes are clouded. address is actually for unit 1, not unit 3. NOTE: permit is pulled under PCIS#16041-10000-14571(((((PV1 INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A MULTI-FAMILY HOUSE.(10) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER:SOLAREDGE SE3000A-US-ZB-U	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14415	14041-10000-04022	1055 S MAPLE AVE	90015	14	126A209   267	5145020048	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.03742	-118.25529	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14416	13041-10000-23449	920 W DOWNEY WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.02063	-118.28879	First floor lab remodel for USC campus building.  Not a highrise per applicant.  T24 plan check only for relocated lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14417	14041-20000-17677	235 S BERENDO ST	90004	13	135B197    85	5518022016	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.0698	-118.29432	Remodel of existing apartment.  Replace indoor/outdoor of general lighting in common areas.  No change in lighting controls.  Plan check for energy only. Note: Permit is under 14041-20000-19275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14418	12041-10000-30849	545 S FIGUEROA ST LV 1 SP 2	90071	14	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM			PC Approved	02/11/2013 12:00:00 AM	ADDRESS	34.0514	-118.2582	BB6187 Jonathan Club. men's clothing store.T.I. OF RETAIL SPACE. APPLICATION FOR T24. FIRST FLOOR OF HIGH RISE. 13 FLOORS.RETAIL SPACE 2. 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14419	12041-10000-27760	2415-2423 W WASHINGTON BLVD	90019	10	126B189   912	5073020002	[Q]CM-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	06/17/2013 12:00:00 AM	PIN	34.04012498	-118.3148908	Core and shell building with no parking space.  New overhead 600 Amp service.  Methane Zone.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14420	19041-20000-51182	11951 W PINNACLE PL	90210	2	156B165   100	2382020053	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.12513	-118.39743	800A 240/120V 1ph-3w service and distribution for SFD.  Plan check only - elec. permit fees paid under building combination permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14421	14041-10000-11947	23903 S NORMANDIE AVE	90710	15	042B197   226	7438017***	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Issued	07/08/2014 12:00:00 AM	ADDRESS	33.80859	-118.2989	plan check for power only. INSTALLATION OF 2 METER SWITCH FOR MICROTURBINES. conduits run through hazardous location. Scope of work is shown as clouded items.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14422	14041-20000-20254	8325 N CAPPS AVE	91324	12	192B121   698	2785016007	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.22167	-118.53972	New roof mounted PV sytewm with Enphase Microinverter model M215-60-2LL.  Total system size 4.085KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14423	17041-10000-36332	4227 W 59TH ST	90043	8	105B181   161	4019006029	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	33.9872	-118.34861	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.25KWdc / 4.830KWac. USING 21 MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14424	14041-10001-34842	8560 W DAY ST	91040	7	204B189   938	2560035028	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.25415	-118.31992	Expedited plan check fee Installation of new roof mounted solar PV array.  Total system size = 8 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14425	19041-20000-17836	4838 N CALDERON ROAD	91364	3	168B097   254	2076004022	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.15799	-118.61999	800A 240/120V 1ph-3w service for 2-story SFD.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14426	13041-10000-34496	2593 N BEACHWOOD DR	90068	4	154-5A189 271	5585007021	RD2-1XL	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.11767	-118.32174	PV1, Install a 1.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[POWER-ONE # AURORA PV1-3.0-OUTD-S-US] and (6) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14427	15041-10000-00201	7274 W HILLROSE ST	91042	7	207B197   882	2566010001	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.26267	-118.2911	Installation of new roof mounted solar PV array.  Total system size = 10.2 kWac. 2 inverters with 50 modues (4 strings total).$ 0 PERMIT FEE IS DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14428	11041-20000-06695	11600 W SHERMAN WAY	91605	6	183B169   692	2320001029	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.20097	-118.38442	Replace emergency generator from 60KW to 150KW (Legally Standby System).  Plan check for power only.NOTE:  Permit also issued under 11041-20000-00232	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14429	15041-20000-18610	10615 W BURBANK BLVD	91601	2	174B177   571	2415023004	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.1723	-118.36214	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 1,756 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14430	16041-30000-35134	901 S GRAMERCY DR	90019	4	132B193   877	5092023013	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.05556	-118.31236	Installation of fire alarm system in new 4 story 21 unit apartment building. Total system size = 1 FACP + 99 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14431	11041-10000-25308	701 W CESAR E CHAVEZ AVE SUITE 102	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Closed	07/12/2012 12:00:00 AM	ADDRESS	34.06107	-118.24412	TENANT IMPROVEMENT FOR GROCERY STORE W/ RACKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14432	10041-10000-25263	11819 W WILSHIRE BLVD #214&#215-2nd Floor	90049	11	129B145   766	4265013087	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	PIN	34.04800716	-118.46324217	CHANGE OF USE FROM MEDICAL OFFICE TO RETAIL/YOGA STUDIO IN SUITE #'S 214 & 215 ON THE SECOND FLOOR.  T.I. FOR A YOGA STUDIO. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14433	12041-10000-06295	1508 W PALOS VERDES DR NORTH BLDG D	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77937	-118.30391	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building D. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14434	16041-20000-27240	6025 N RHODES AVE	91606	2	177B165  1097	2333011045	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.18018	-118.4032	Plan check for PV roof mounted system. System size: 5kW   with 20 modules and 20  microinverter. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14435	17041-20000-12804	22450 W SHERMAN WAY	91307	12	183B101    99	2024016109	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.20073	-118.61672	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 2ND FLOOR OF (E) CHURCH.BUILDING PERMIT # 17016-20000-09985	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14436	16041-10000-14128	5343 W IMPERIAL HWY #900	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	33.93128	-118.37337	T-24, PC FOR ENERGY ONLY. TI TO A TWO-STORY EXISTING COMMERCIAL BUILDING(OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 9010 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14437	18041-20000-36812	1030 N SWARTHMORE AVE 3-105A	90272	11	129B125   668	4412002016	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	07/21/2023 12:00:00 AM	ADDRESS	34.04776	-118.52525	Plan check for Title 24 Energy only for retail T.I. Total area: 337 sq ft.18016-10000-19862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14438	19041-10000-40300	419 S SPRING ST	90013	14	129A211    54	5149024027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	08/07/2020 12:00:00 AM		Permit Expired	06/04/2024 12:00:00 AM	ADDRESS	34.04843	-118.24885	FULL PC FOR POWER AND ENERGY. ADAPTIVE  REUSE OF  AN EXISTING OFFICE BUILDING TO BE CONVERTED TO A 180 ROOM  HOTEL. CHANGE  OF  USE FROM  OFFICE  TO  HOTEL, FIRST FLOOR RESTAURANT CORE AND SHELL ONLY.  SCOPE INCLUDES TWO NEW 1200A 480V 3 PHASE 4 WIRE SERVICE. TOTAL AFFECTED AREA IS 64139 SQ. FT. B#13016-10000-26325	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14439	11041-20000-18940	1305 S ABBOT KINNEY BLVD	90291	11	108B145  1166	4239027002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	33.99127	-118.46797	New RestaurantRequest for Modification to separate Methane detection system filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14440	14041-20000-11477	9561 W SAWYER ST	90034	5	129B165   969	4309011019	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Info Complete	10/31/2014 12:00:00 AM	PIN	34.04581799	-118.39741157	New (2 story with basement) single family dwelling and single story guest house with 600A service in a methane zone.Methane mitigation system approved by building plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14441	14041-20000-03384	6600 N TOPANGA CANYON BLVD Suite 1078	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI FOR INTERIOR OF EXISTING RETAIL SPACE. PERMIT PULLED UNDER APPLICATION#: 14041-10001-03384	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14442	09041-10001-24233	705 S OLIVE ST 705A	90014	14	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM			PC Approved	01/22/2010 12:00:00 AM	ADDRESS	34.0465	-118.25601	INSTALL 11 NEW T-BAR, 4-32 WATT 2'X4' FIXTURES, 6 TRACK FIXTURES, AND 3 PENDANT FIXTURES, AND EXIT SIGN.  (SUITE A / RETAIL 6)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14443	14041-20000-26081	4835 N OAK PARK AVE	91316	5	168B133   168	2289004009	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.15873	-118.50467	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012PV1.  Install 14.5 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14444	11041-10001-03491	16710 W VENTURA BLVD 1-125	91436	5	168B137   335	2289020019	(Q)C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Apartment			08/25/2011 12:00:00 AM	08/26/2011 12:00:00 AM		Permit Expired	09/18/2013 12:00:00 AM	ADDRESS	34.15819	-118.49729	Plan check for new roof mounted 167.6KW photovoltaic system.(((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((addition of 800 amps ac disconect out side of the building.))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14445	16041-20000-15092	8706 N STANSBURY AVE	91402	6	195B153  1026	2638009009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.22821	-118.44343	PV1. ROOFMOUNTED SOLAR SYSTEM.  AC MODULES SYSTEM. SYSTEM SIZE: 6.54 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14446	16041-20000-34881	6111 N TOPANGA CANYON BLVD	91367	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	05/01/2018 12:00:00 AM		Issued	05/01/2018 12:00:00 AM	ADDRESS	34.18157	-118.60615	Plan check for power and energy. TI to existing 2-story car dealership/repair garage. New 800A service and distribution/loads. New lighting - 14,106sqft indoor; 4,234sqft outdoor. Note: some panels located in service bay area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14447	14041-20001-20275	20558 W TIARA ST	91367	3	174B109    25	2151018048	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.17699	-118.58155	$0 permit fee due to senate bill 1222 from 2012increase system 1 modules. total system size now consist of 22 modules. still 3.6kw AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14448	16041-20000-05820	1250 S OGDEN DR	90019	10	129B177   110	5086017025	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.05327	-118.36345	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14449	16041-20000-10862	445 S FIGUEROA ST 3RD FL	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 3RD FLOOR. 759 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14450	16041-10000-41221	1100 S GLENDON AVE #710	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.06074	-118.44418	T-24, PC FOR ENERGY ONLY. TI TO AN OFFICE SPACE IN AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS FOR AN OFFICE SPACE FOR SUITE 710. TOTAL AFFECTED AREA IS 2430 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14451	17041-10000-36260	4210 N EAGLE ROCK BLVD	90065	1	156A219   149	5472001012	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Issued	10/10/2017 12:00:00 AM	ADDRESS	34.12177	-118.22478	INTERIOR ALTERATION-REPLACE HID WITH  LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14452	15041-20002-12630	1440 S VETERAN AVE	90024	5	129B153    17	4324038***	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			04/22/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.05284	-118.44327	04/22/2016 Changes to an approved set of plans. Changes have been made to reflect field changes; changes have been made to the lighting floor plan and the power plan. *****Previous Work Description*****Changes to an approved set of plans. Moving location of emergency lights.Plan check for T-24 only. Remodel the common area in The Colony. Total area: 3,327 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14453	13041-10000-20299	145 S FAIRFAX AVE	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	PIN	34.07292853	-118.36175524	Exterior lighting for 3-story commercial building.  New light fixtures at 1st, 2nd, and 3rd floor exterior and in parking garage.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14454	15041-10000-26271	22200 W SHERMAN WAY	91303	3	183B101   106	2024013189	C1-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.20073	-118.61062	NEW RESTAURANT 800 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14455	19041-20000-21196	5120 N WINDERMERE AVE	90041	14	163-5A221 314	5671017009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.14041	-118.21711	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 9KW DC/7.875KW AC. SCOPE OF WORK INCLUDES (25) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND (2) 100A SOLAR LOAD CENTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14456	10041-10000-01906	701 N STONE CANYON ROAD Bldgs 1-5	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM			PC Approved	05/19/2010 12:00:00 AM	ADDRESS	34.08578	-118.44515	Plan check for new construction at Bel-Air Hotel.  Plan check is for all 5 structures (villas) which are separated from main hotel area.  P/C is for Power and Energy.  This application number is used for plan check of all the buildings. The permit applications for the villas  will  be individually issued.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14457	15041-20000-03162	6256 N TOPANGA CANYON BLVD C-2270	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	TI FOR YOGAWORKS TOPANGA CANYON (WESTFIELD).  FIRST TIME TENANT. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14458	13041-10001-24253	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	4/14/2014- CHANGES MADE TO APPROVED SET. DELTA 7 CHANGES ONLY. CHANGES TO T24 AND CIRCUIT RELOCATION. THIS IS A PLAN CHECK ONLY APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14459	10041-20000-24819	700 W CHILDS WAY 1st Floor	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.01978	-118.28463	Plan check T24 Energy for USC John Hubbard Hall 1st floor TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14460	07041-10005-26513	940 E 2ND ST	90012	14	129A217   202	5163006017	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			05/18/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	34.04698	-118.23369	REVISED PLANS TO ADDRESS INSPECTION CORRECTION NOTICE U 29078UNIT C AND E DOWN SIZE ELECTRIC OVEN RATING AND UPSIZE THE CU UNITS AND INSTALLED LOW VOLTAGE LUMINAIRE IN  ROOM ON THE THIRD LEVEL (((((((REMODEL EXISTING 10 JOINT LIVING AND WORKING QUARTER RENTAL UNITS FOR ARTISTS AND ARTISANS AND CONVERSION OF REMAINING EXISTING M3-1 ZONED INDUSTRIAL WAREHOUSE BUILDING INTO 30 UNIT JOINT LIVING AND WORKING QUARTER CONDOS FOR ARTISTS/ ARTISANS & PARKING GARAGE. A TOTAL OF 40 UNITS FOR THE PROJECT. WITH ON SITE PARKING.  METHANE ZONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14461	10041-20000-09882	21526 W VENTURA BLVD	91364	3	171B105    60	2168001053	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM			Corrections Issued	05/25/2010 12:00:00 AM	ADDRESS	34.16796	-118.59949	INSTALLING LIGHTING AND POWER FOR RETAIL STORE. P/C IS ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14462	18041-10000-39405	3510 E PICO BLVD	90023	14	118-5A225 316	5191021020	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.0179	-118.20231	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14463	11041-10000-18894	515 S FLOWER ST	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	T.I. TO AN EXISTING OFFICE BUILDING.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14464	11041-20000-26868	9301 N TAMPA AVE # 218	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for electrical system upgrade for conversion of suite 218 into two future restaurant spaces and for site lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14465	13041-10000-23899	18001 S FIGUEROA ST SUITE F	90248	15	063B201   174	7339008001	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	33.86778	-118.28182	Remove (E) HID light fixtures and install new light fixtures as per DWP rebate program.  Title 24 plan check only.  No emergency lighting or exit signs in tenant space as per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14466	17041-10000-36294	4751 S BROADWAY	90037	9	111A203    11	5110015001	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34	-118.27855	REPLACE 800 SERVICE WHICH WAS DAMAGED AND ADDED PANELBOARD IN VACANT TENANT SPACE; ALL LOADS ARE THE SAME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14467	14041-10000-11143	12426 W VERDI ST	90066	11	108B157  1498	4221005077	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	33.98902	-118.41971	PV1, INSTALL 6.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE6000A-US-ZB-U(25) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14468	13041-10000-24969	549 S MORENO AVE	90049	11	129B137   606	4264004004	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.04641	-118.48747	PV1 9.6KWAC 240V XFMR (neg grounded) INV. 2STORY. STD. ROOFMOUNT.[( 2) INV: advanced energy industries, inc. PVP4800][( 32) MOD: mono X LG2551c-g2]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14469	18041-10000-13143	5865 S CAMPUS CENTER DR SUPPORT-AREAS	90094	11	102B161  1149	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	IN AN EXISTING AIRPLANE HANGER(2 OF 2), TWO SOUNDSTAGES ARE TO BE BUILT; THIS APPLICATION IS FOR THE POWER AND LIGHTING INSTALLATION FOR THE SUPPORT 18014-10K-01915 AREAS-CORRIDORS,RESTROOMS, OFFICES AND ELECTRICAL ROOMSNOTE : TWO UNIT SUBSTATIONS TO BE SUPPLIED FROM EXISTING MVSWG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14470	13041-20000-30519	1901 S AVENUE OF THE STARS	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Expired	12/17/2015 12:00:00 AM	ADDRESS	34.05949	-118.41705	PC FOR T24 ENERGY ONLY. EXISTING CORRIDOR IN OFFICES. TOTAL AREA 1410 SQ FT. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14471	15041-20001-00821	17200 W OAK VIEW DR	91316	5	168B133   392	2289015001	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.15531	-118.50619	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 7.525kW. Ungrounded system.35 EnPhase M215 microinverters with 35  270W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14472	14041-10000-27706	6468 N PENFIELD AVE	91367	3	180B113   668	2134039007	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.18843	-118.56884	PV1 roof mouned system including (1) Solaredge SE5000 inverter, (20) Canadian Solar CS60-250 modules and Solaredge P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14473	16041-20000-05968	9723 W BEVERLYWOOD ST	90034	5	126B165   777	4309006001	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.03991	-118.39849	Plan check for PV roof mounted system. System size: 13.16kW with 47 modules and  47 microinverter Enphase.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14474	15041-20001-28470	1425 N VIA ANITA	90272	11	132B121   162	4420038009	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.05838	-118.53831	Expedite per applicant requestPlan check for PV roof mounted system. System size: 10.0kW with 36 modules and 1 inverter(10.0kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14475	14041-10001-28281	8635 W 3RD ST Ste 590	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.07373	-118.38073	Modifications to approved set.  Delta-3 revisions.  Changes to architectural layout, slight lighting system revisions related to quantity/orientation of luminaires.  Affected sheets: all sheets submitted for revisions. (((T.I. to medical office.  Installation of lighting and recepticles.  Total area = 5341 sq. ft.)))Permit is under master and supplemental, supplemetal to cover relocate circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14476	13041-10001-27881	888 W SUMMERLAND AVE	90731	15	018B197   201	7447015007	R2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	33.74773	-118.29633	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 3.75/ 2 STORY HOUSE. TRANSFORMERLESS UNGROUNDED.(15) TRINA SOLAR # TSM-250PA05.18(1) POWER ONE # AURORA PVI-3.0-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14477	15041-10001-24207	9110 N VAN NUYS BLVD	91402	6	198B149   535	2639008025	[Q]C2-1VL, [T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Expired	11/03/2017 12:00:00 AM	ADDRESS	34.23602	-118.45005	Change to approved set by adding (1) communication panel and (5) fire alarm devices. All changes are under delta-1 only.(((NEW FIRE ALARM SYSTEM WITH (33) DEVICES , ONE CONTROL PANEL , AND ONE FA PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14478	14041-20000-28257	1800 CENTURY PARK EAST #420	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	PIN	34.06270629	-118.4150769	TI TO SUITE 420. NEW LIGHITNG. OFFICE. PC FOR T24 ENERGY ONLY. PERMIT FOR LIGHITNG ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14479	15041-10001-04646	2801 S SAN PEDRO ST	90011	9	118-5A207 124	5128013028	CM-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM			PC Approved	04/01/2015 12:00:00 AM	ADDRESS	34.01983	-118.26264	Changes to layout and circuiting of receptacles in offices.  (((Plan check for power and Title 24 (energy).  Total area = 4,093 sq. ft.T.I. to medical office/clinic including lighting and recepticles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14480	12041-10000-24171	401 S OCEAN FRONT WALK 1-45	90291	11	109-5A141 128	4286029001	R3-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Expired	05/03/2016 12:00:00 AM	ADDRESS	33.99386	-118.47965	NEW RESTAURANT INSIDE EXISTING CADILLAC HOTEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14481	17041-20000-28729	11950 W FOOTHILL BLVD	91342	7	210B165    41	2532012039	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.2757	-118.3967	Plan check power and energy for Interior TI (planet fitness) - change of use from retail/grocery to fitness center/gym. Scope includes new panels circuits, equipment and lights (incl. emergency)Total affected area indoor 19,779sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14482	17041-10000-35244	515 S FLOWER ST 17TH FL	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	new luminaires in men & women rest rooms using existing branch circuitsPLA CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14483	14041-10000-36070	3129 E FAIRMOUNT ST	90063	14	129A229    77	5178001022	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2038.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.0479	-118.19413	PV1.  Install 4.578 kW roof-mounted, utility-interactive PV system.  Standard plan for central inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14484	19041-10000-18454	660 S FIGUEROA ST	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM			Verifications in Progress	08/15/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	Full PC for a new TI in an exisiting high rise building (1st floor only, currently an empty corn and shell). Scope of work includes new electrical distibution and equipment and lighting. Total affected area is 2055 sqft. From building:(((E) RESTAURANT TENANT IMPROVEMENT TO INCLUDE ALL NEW INTERIOR WALLS, FINISHES, FISTURES, AND MEP SYSTEMS  4102 SF))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14485	11041-20000-17591	11932 N MALLOT PL	91344	12	216B137   315	2609008016	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2011 12:00:00 AM	09/07/2011 12:00:00 AM		Permit Finaled	12/20/2011 12:00:00 AM	ADDRESS	34.28745	-118.49544	NEW ROOF MOUNTED 8.28KW PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING AND SERVICE PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14486	14041-20000-27780	23239 W VANOWEN ST	91307	12	183B093   697	2026020007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.19388	-118.63295	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.7KW INTERCONNECTED WITH MSP.(22) SOLAR WORLD SW 250 MODULES(22) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14487	17041-20000-20819	100 N LARCHMONT BLVD	90004	4	138B189   973	5515024017	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.07321	-118.32343	Plan check for energy only. TI to bank (Bank of America). New lighting (incl. emergeny) - 2,843sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14488	12041-20000-27693	19654 W VENTURA BLVD	91356	3	174B117   352	2164014011	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.17241	-118.56181	Plan checked only for T-24 lighting plan check for addtional lighting in office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14489	19041-10000-12710	5200 N LANKERSHIM BLVD UNIT 120	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Issued	07/19/2019 12:00:00 AM	ADDRESS	34.16511	-118.37448	Energy plan check for an office T.I located in the first floor of a  high rise building. Scope inlcudes new lighting and equipment with a total area of 1876-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14490	17041-20000-18429	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM			PC Approved	06/02/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	ti to an existing commercial sapce.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14491	11041-10000-08633	189 S THE GROVE DR Ste# H80	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	PER CUSTOMER REQUEST, FULL PLAN CHECK.  EXISTING GAP STORE BE DIVIDED TO ACCOMODATE ANOTHER TENANT IN EXISTING RETAIL SPACE.  CUSTOMER WOULD LIKE THIS PLAN CHECK TO BE ACCOMPANIED BY PCIS# 11041-10000-08624.  PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14492	14041-20000-33504	510 S NORMANDIE AVE 1-40	90020	10	135B197   812	5502018022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			11/05/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	34.06494	-118.30016	PV2Install roof-mounted solar array on Apartment building. Interconnect with 100A service.System size: 3.0kW. Grounded system.(8) 305W pv modules across 1 string.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14493	19041-10000-40943	3375 N NORTH KNOLL DR	90068	4	159B181   565	5579031013	R1-1	South Valley				1897.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.13045	-118.34409	PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER WITH 12 MODULES USING P320 OPTIMIZERS AND ESS(LG-RESU10) WITH RELOCATED BACKUP LOADS AND INTERCONNECTION WITH EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14494	16041-10000-10369	11150 W OLYMPIC BLVD	90064	5	126B153   956	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.03956	-118.43857	T-24, PC for energy only. TI for an existing high rise commercial building on the 8th floor. Scope includes new lighting fixtures for the 8th floor corridor and restrooms. Total affected area is 1710 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14495	13041-20000-07445	909 W TEMPLE ST	90012	14	133-5A211 268		C4-2D, R4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Apartment			03/22/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.06102	-118.24942	New fire alarm for a new 435 unit apartment building.  Bldg A  at 909 Temple and  Bldg B  at 900 Temple	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14496	18041-20000-32913	17825 W OSBORNE ST	91325	12	195B129   105	2768030008	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.23376	-118.52234	Plan check for PV roof mounted system, system size: 7.6KW with 22 modules and 1 inverter(7.6kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14497	15041-10002-00849	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Change to approved set by changing the light fixture on the floor plan; All changes are under delta-B only.(((Office TI by remodeling an existing westfield security office in topanga mall.PLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14498	19041-10000-19731	7303 N ATOLL AVE	91605	2	186B157   515	2327002030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.20322	-118.42119	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14499	13041-20002-35636	11554 W CANTON DR	91604	2	159B169   356	2377016018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Expired	02/09/2016 12:00:00 AM	ADDRESS	34.13293	-118.38551	(((CHANGES MADE TO APPROVED SET. ADDED 2 MODULES [ONE PER STRING].)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 2 TRANSFORMERLESS INVERTERS, NONSTANDARD PLAN. ALL ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14500	12041-20000-06753	14006 W RIVERSIDE DR Dining-Terrance	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Delta 2 revision of previously approved p/check consist of upsizing feeder conductors and breakers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14501	14041-20000-31658	13212 W GLAMIS ST	91331	7	204B157   968	2623012015	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.2539	-118.42052	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(16) SUNPOWER 327W MODULES(1) POWER ONE 5000 TL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14502	13041-10000-24300	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	33.94955	-118.38214	First floor production area electrical upgrades.  New distribution board and kettle motor control centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14503	18041-10003-32413	5628 E KENDALL AVE	90032	14	147A239    41	5309026020	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.09851	-118.1574	PC delta 1 only (change orientation of pv panels only).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14504	14041-10000-14290	5700 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	34.06218	-118.35303	T24 FOR A COMMERCIAL BUILDING COURTYARD AND RESTROOM AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14505	14041-20000-00912	13310 W BERG ST	91342	7	228B157   126	2511013025	RA-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.32488	-118.42189	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14506	17041-20001-32783	19208 W BRIARFIELD WAY	91356	3	162B117   196	2177047006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.141	-118.55235	Revision to approved set of plans.  Wiring detail changes.  (((Plan check for the addition of (2) Tesla Powerwall to an existing PV1 roof-mounted PV system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14507	14041-20000-26287	14977 W LARKSPUR ST	91342	7	228B145   289	2502012068	R1-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Expired	10/18/2016 12:00:00 AM	ADDRESS	34.3204	-118.45905	central string inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14508	19041-10000-20514	1411 S LINCOLN BLVD	90291	11	111B145  1243	4241008033	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Issued	05/31/2019 12:00:00 AM	ADDRESS	33.99757	-118.46044	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14509	15041-10001-27860	14353 W VICTORY BLVD	91401	6	180B149   829	2237022025	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.18686	-118.44624	CHNAGES TO APPROVED SET OF PLANS. NEW SET TO INCLUDE SCOPE OF OUTDOOR WORK. NEW LIGHTING. CHANGES TO OUTDOOR TITLE 24. PERMIT TO BE ISSUED TO CORRECT ENGINEER ON RECORD AND ISSUE PERMIT FOR OUTDOOR LIGHTING FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14510	18041-20000-17966	20621 W CHESTNUT CIR (#278)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.29306	-118.58351	Plan check for a PV1 roof-mounted PV system. System size is 2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14511	19041-10000-11258	3325 E UNION PACIFIC AVE	90023	14	117A223    13	5190031003	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Issued	04/16/2019 12:00:00 AM	ADDRESS	34.01657	-118.20803	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 31 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14512	14041-10000-06764	4521 N SHERMAN OAKS AVE 2ND FL	91403	5	168B145  1045	2283017030	CR-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.15295	-118.46946	PLAN CHECK FOR ENERGY AND POWER. NEW DENTAL OFFICE. UPGRADING TO 600A SERVICE. 2-STORY OFFICE BULDING.BUILDING PERMIT#13041-20000-04707.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14513	15041-10000-32865	1050 S OGDEN DR 1/4-3/4	90019	10	132B177   905	5086018030	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			10/05/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.05636	-118.36216	PC FOR METHANE MITIGATION  SYSTEM-LEVEL ONE- 3 STORY APARTMENT BUILDING . 1/4 THRUOGH 3/4 ARE THE ADRESSES FOR 3 STORIES.  EPC APPROVAL COVERS ONLY CONDUIT SEAL DETAIL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14514	16041-20000-40979	10245 ANGEL LANE	91331	7	204B165   432	2537004042	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25661319	-118.40446509	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14515	18041-20000-34491	20609 W CHESTNUT CIR #284	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.29266	-118.58375	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14516	10041-20000-17870	601 S FIGUEROA ST #2725	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM			PC Info Complete	09/09/2010 12:00:00 AM	ADDRESS	34.05076	-118.25881	energy plan chek suite # 2725	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14517	14041-20000-04969	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.10686	-118.33085	T.I. to existing building, Suite 105.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14518	13041-10000-35246	1188 S SAN PEDRO ST G	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	PIN	34.03375994	-118.25280059	Title 24 only change light fixttures to save enrgy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14519	18041-10000-04275	17819 W MERRIDY ST	91325	12	204B129   458	2734006009	(Q)R3-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.25233	-118.52224	PC for T24 only for replacement of outdoor metal halide fixture with new LED fixtures. Total area 60900qft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14520	11041-10000-16792	20871 W LASSEN ST	91311	12	201B109    90	2741002005	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.25013	-118.58828	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14521	15041-10001-08435	15 E PALOMA AVE 1-58	90291	11	109-5A141 137	4286021002	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Apartment			03/23/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM	ADDRESS	33.9937	-118.47885	Expedite per customer request.(((PV2 19.6KWroof-mounted system with (86) Polycrystalline Solar Module Q.PRO-255, (3) 5.0kw Growatt inverters and (1) 4.2 Growatt inverter interconnecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14522	19041-20001-51429	1943 W ESTES ROAD	90041	14	163-5A223  39	5671005009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			Reviewed by Supervisor	01/02/2020 12:00:00 AM	ADDRESS	34.14385	-118.21089	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14523	19041-10000-29012	523 W 6TH ST 7TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.04864	-118.25484	ENERGY PC ONLY FOR NEW UNISEX RESTROOM IN THE 7TH FLOOR,  AREA 445SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14524	17041-20000-05262	5877 W RODEO ROAD	90016	10	120B173   334	4205027016	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.02201	-118.3753	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from office/manufacturing to multimedia production and a tenant improvement. Total lighting area = 14,275 sq. ft.Note: Building application has been generated under 17016-20000-03650	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14525	13041-20002-21016	4591 N DE CELIS PL	91436	5	168B137   642	2284009042	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.15411	-118.49356	(((CHANGES MADE TO MODULE ORIENTATION AND STRINGING ONLY. NUMBER OF MODULES DID NOT CHANGE)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 13.08 KW. 40 MODULES AND 2 INVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14526	13041-10000-02475	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	33.94248	-118.40461	This is atemp power  fed from an existing switch gear intented to use for construction in terminal 5 delta air line.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14527	15041-20002-36994	9504 N WHITAKER AVE	91343	12	198B133    42	2686020009	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/04/2015 12:00:00 AM	ADDRESS	34.24325	-118.499	$0 plan check fee due to Senate Bill SB-1222.  Revisions to approved set.  Change of AC disconnect specifications to not include a viewing window (not a required feature).  (((PV1, roof mounted solar 12.7kW AC(44)modules: SPR-327NE-WHT-D(1)inverter: SunnyBoy 5000TL-US(1)inverter: SunnyBoy 7700TL-US)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14528	15041-20001-09465	5424 S CRENSHAW BLVD	90043	8	108B185   458	5006008008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	33.99235	-118.33045	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 10.5 KW.  35 CANADIAN SOLAR MODULES(5 )GRO WATT INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14529	13041-10000-35543	8241 W FOOTHILL BLVD	91040	7	204B193    44	2555022006	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.25986	-118.31283	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR STARBUCKS. 2838 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14530	14041-10001-17044	600 WORLD WAY TER # 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	03/16/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	03/16/16PC for power only. Scope includes temporarily relocating an 800A distribution board, 'C4C1A' to less than 10 feet away from distribution board 'C4C1'. PC for tap conductors connecting switchboard 'C4C1' to switchboard 'C4C1A'NOTE: Permit pulled under PCIS#14041-10000-17044 (((((TERMINAL 6 POWER DISTRIBUTION SYSTEM UPGRADEREPLACE PANEL AND DISTRIBUTION BOARDS AS NEW MV SERVICE WAS PERMITTED UNDER SEPARATE APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14531	16041-10000-30958	5633 N FIGUEROA ST	90042	1	151-5A229 222	5468033021	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.10956	-118.19323	Plan check Title 24 only in existing space Barber shop single story building. Total area: 1205 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14532	17041-10000-37650	8474 W 3RD ST STE 101	90048	5	138B173   785	5511032060	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM			PC Approved	11/08/2017 12:00:00 AM	ADDRESS	34.07314	-118.37566	CHANGE OF USE OF (31' X 39') PORTION OF EXISTING RETAIL TO OFFICE (JENNY CRAIG)plan cheeck is for title 24 only as electrical permit was obtained separately	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14533	12041-20001-15461	14600 W ROSCOE BLVD	91402	6	192B149   406	2210010033	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.22136	-118.45025	Modification to previously approved set of plans.  State Licensed Medical - Check for OSHPD3.  Space was sold to new owner and modifications are made for new tenant.    <<<Dialysis Center.  Plan check power and emergency lighting.  Exempt from T24 as I-2.1 Occupancy.  Variance to separate the fire alarm system was submitted on December 10, 2012.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14534	14041-20000-06670	6562 N ENSIGN AVE PV 1	91606	2	180B173   523	2336003023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Expired	04/06/2016 12:00:00 AM	ADDRESS	34.1901	-118.37164	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 2.59KWAC. ZONING ALREADY CLEARED ON APPLICATION#: 12041-20000-30683	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14535	17041-10001-09684	7822 N TAMPA AVE	91335	3	189B117   729	2104007035	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM			PC Approved	04/21/2017 12:00:00 AM	ADDRESS	34.21279	-118.55334	Addition of a new pv system to existing system on a single family home. Adding 12 Microinverters (3KW).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14536	17041-20000-27703	9330 W FLICKER WAY	90069	4	147B165   487	4392006018	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2017 12:00:00 AM			PC Approved	07/25/2019 12:00:00 AM	ADDRESS	34.09626	-118.39358	Plan check for power only. New 2-story SFD w/att. garage above 1 level basement.1000A 120/240V 3ph 4w service.building permit # 16010-30000-03709Note: Permit has been paid under Building application PCIS#17041-20000-27703. plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14537	15041-10002-17391	15857 W STRATHERN ST	91406	6	189B141    30	2206005023	C4-1VL, M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.21581	-118.47928	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE DELTA 9 AND 10 REVISIONS. NEW LIGHITNG IN OFFICES AND NEW FIXTURES. RELOCATION OF LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14538	09041-10001-22940	330 N HAYWORTH AVE	90048	5	138B177   248	5527036022	R4-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			01/08/2010 12:00:00 AM			PC Approved	01/08/2010 12:00:00 AM	ADDRESS	34.07706	-118.36251	Supplemental is for changes to panel schedule designation.  Several ckts are now indicated as existing and relocated to match as-built.  ::   Replace outlets and lights and add circuits for a kitchen on the first floor.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14539	19041-10000-09320	624 S GRAND AVE 29th floor	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	PC T24 only for PORTION OF 29th FLOOR FOR (STORAGE) EQUIPMENT ROOM. SCOPE OF WORK AREA 8839SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14540	16041-20000-08595	1315 E OPP ST	90744	15	033B213   613	7425033022	[Q]R2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Issued	03/11/2016 12:00:00 AM	ADDRESS	33.78382	-118.24702	Install a roof-mounted solar array on a Duplex residential building.System: 5kW. Ungrounded system. (16) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14541	13041-10001-35622	11975 W BLUFF CREEK DR BLDG#5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	33.98224	-118.40247	Changes to approved set; Instead of overhead severice, applicant change it to underground. There are also minor changes to title 24. Note per F.Y request.(((CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  35945 SF WITH NEW SURFACE PARKING LOT. TITLE 24 ENERGY FEE CHARGED UNDER BUILDING 3.  3 TOTAL BUILDINGS.  THIS IS BUILDING 5/5 IN THE SAME PARCELBLDG PERMIT: 13010-10000-04245	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14542	18041-30000-45977	10100 W SANTA MONICA BLVD STE 190	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	PC for energy only. Tenant improvement to Suite 190 (1,150 SF).  Scope of work to includes new lighting and receptacles in an existing high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14543	19041-10000-07930	9324 S SAN PEDRO ST	90003	9	094-5A205 452	6052022009	RD2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	33.95125	-118.26935	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH LED FIXTURES T 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14544	11041-10000-22381	350 E 1ST ST	90012	9	129A215   347	5161017022	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	10/28/2011 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.04935	-118.23978	TENANT IMPROVEMENT IN PIZZA SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14545	15041-20000-14641	21700 W OXNARD ST suite#1220	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for Title 24 only high rise building Warner Center Tower III Suite # 1220. Remodel existing spece with all net light fixtures .Total area: 1620 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14546	11041-20000-24590	5243 N MONTE BONITO DR	90041	14	163-5A229 199	5691020010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2011 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.14197	-118.19059	New 3.648 KW roof mounted PV system for a single family residence.  System is using ENPHASE M215.  A variance has been filed for the use the microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14547	11041-10005-14514	7149 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	PIN	33.94386821	-118.41794839	(((((((((((((((((((((((( Changes made to previously approved set, two pull section added .   08-14-12  ))))))))))))))))))  NEW FIRE WATER DELUGE PUMP BUILDING AT LAX.  FULL PLAN CHECK.((((((( changes made to previously approved set, remove exhust fans from emergency board feedinf fire pumps and remove neutral from the wiring system. 3-2-12))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14548	18041-20000-33468	16150 W VANOWEN ST	91406	6	180B137    17	2233030001	RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	Apartment			08/31/2018 12:00:00 AM			Reviewed by Supervisor	10/17/2018 12:00:00 AM	ADDRESS	34.19368	-118.48549	Plan check for power and energy for 16 units multi-family 3 story building 800A service. Total area: 12,226 sq ftB#18010-10000-00354	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14549	14041-10001-15434	3640 W WILSHIRE BLVD	90010	10	132B193    62	5093019018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			02/24/2016 12:00:00 AM			PC Info Complete	02/29/2016 12:00:00 AM	ADDRESS	34.06145	-118.30446	2/24/16: Changes to approved set:1. Panel relocation on some residential units2. Relocate corridor light fixtures B1 (type and unit remain the same, NO changes on T-24)3. Updated unit numbers with typical unit types.4. Added laundry circuit to units: E1, E2, S1, S2. Total of 21 new branch ckt. <<plan check for power and energy. 28 Typical units. fire alarm variance required. not methane. zone.BLDG#13010-10-01719: 7 Stories 209 Dwelling units Apartment w/  2 Basement Levels parking>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14550	16041-20000-11986	16836 W DEVONSHIRE ST	91344	12	204B133   221	2685002041	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.25731	-118.49947	Plan check for power and energy. Project site is an existing building. Project scope is a change of use from retail to restaurant. Total lighting area = 4,245 sq. ft.Note: Building application as been created under 15016-10000-25949	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14551	13041-10000-33781	1850 W SLAUSON AVE	90047	8	108B193  1513	6001001018	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	33.98887	-118.30986	PLAN CHECK FOR T24 ENERGY ONLY. T.I. FOR EXISTING STARBUCKS. 1509 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14552	12041-10000-08537	2275 S GUTHRIE CIR	90034	5	126B165   486	4309017029	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.04216	-118.39302	5.17KW roof mounted PV system with microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14553	19041-10000-21102	1321 S WILSON ST	90021	14	121-5A215 224	5167004005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.02574	-118.235	NEW FIRE ALARM SYSTEM ( VOLUNTARY ) IN A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW FACP AND 36 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14554	19041-10000-25936	9910 N DONNA AVE	91324	12	201B121    80	2729005016	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Issued	08/20/2019 12:00:00 AM	ADDRESS	34.25068	-118.54797	0$ final fees per AB1414PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 42 MODULES (LG 365) WITH 42 OPTIMIZERS (SE P320) AND 2 INVERTERS 7.6KW EACH ( 2 x SE7600H-US). SYSTEM SIZE IS 15.33KWdc AND 15.2KWacSERVICE UPGRADE TO 225A WITH 175A MAIN BREAKER TO BE SEPERATELY PERMITTED UNDER EXPRESS PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14555	14041-20000-18996	9329 GLORY AVE	91042	7	198B201   359	2572044008	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	PIN	34.23840573	-118.27953851	PV1Install roof-mounted solar array on SFD. System size: 7.6kW.(1) SolarEdge SE7600A-US transformerless inverters(34) SolarEdge P300 power optimizers(34) Solar World SunModule SW250 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14556	15041-10000-14931	1253 N NEW HAMPSHIRE AVE	90029	13	147B197  1182	5540015011	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			05/15/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.09498	-118.29342	PV1 INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (16) MODULES: KYOCERA KU606XPA(1) INVERTER: PVI-3.6-PUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14557	16041-10000-44261	11167 W COHASSET ST	91352	2	186B173   461	2315014026	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Issued	01/11/2017 12:00:00 AM	ADDRESS	34.20674	-118.37439	Permit fee is $0.00 due to Senate Bill 1222.Roof mounted solar system for a  single family home. scope includes (2)  new central inverter rated total 10.0 Kw with 41 modules and power optizers.PANNELS LOCATED ON (3) DIFFERENT BUILDING STRUCTURES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14558	07041-10002-24502	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Apartment			07/13/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.05562	-118.27458	Change one elevator form 10 to 40 HP, relocate the RDB2U to room R-102, and change all residential feeders to aluminum MC Cable.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14559	15041-20000-28724	120 S RENO ST	90057	13	138A201   373	5155004025	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM			Reviewed by Supervisor	10/02/2015 12:00:00 AM	ADDRESS	34.07077	-118.28154	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 75KW(204) LG365 MODULES(3) SMA 20000TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14560	10041-20003-04897	2530 E CINCINNATI ST	90033	14	129A225   348	5177033028	R3-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2037.20	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.04626	-118.20433	"Modification to approved set of plans to change fixture ""Q"" for equivelent.  PLAN CHECK ONLY.<<<<New building variety boy and girls community center.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14561	19041-20000-21055	1325 E PALMETTO ST	90013	14	126A217    34	5164003018	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.04045	-118.23165	ti with 800 amp service upgrade to an existing commerciasl building.  plan check for power and energy.building application number 18019-10000-38317	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14562	19041-10000-04320	10100 W SANTA MONICA BLVD 1425	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24 PLAN CHECK FOR TI PORTION OF 14TH FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4203.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14563	19041-20002-20238	21000 W PLUMMER ST Bldg B	91311	12	198B109    41	2746008014	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	34.24253	-118.59179	Plan check for new fire alarm system, total fire alarm devices: 50 and 1 FACP.Note: plan check only, permit covered under Master Application: 19041-90000-20238	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14564	17041-20000-14024	7016 W MELROSE AVE	90038	5	141B181   668	5525017011	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.08325	-118.34346	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BUTCHER SHOP. 917 + 1698 OUTDOOR SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14565	10041-10001-08893	2154 W SUNSET BLVD	90026	13	139-5A207 104	5402030016	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Expired	08/19/2013 12:00:00 AM	ADDRESS	34.07735	-118.26555	Revised approved set of plans- addition of exterior lighting; change of controls for interior lighting; changes on the power planTi for two story existing building. EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14566	15041-10000-20170	6421 W SELMA AVE	90028	13	148-5A187 303	5546007023	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Closed	01/04/2017 12:00:00 AM	ADDRESS	34.09988	-118.33029	PC FOR POWERAND ENERGY. TI. FIRST TIME TENANT. TOTAL AREA 40194 SQ FT.APPLICANT SHOULD BRING A LEGIBLE PLAN BEFOR ASSIGNING THE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14567	10041-20000-20668	10100 S AVIATION BLVD	90045	11	090B173   144	4129029013	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	06/20/2012 12:00:00 AM	ADDRESS	33.94466	-118.37822	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14568	18041-10000-34876	444 S HARBOR BLVD FS 112	90731	15	015B201   221	7440030***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	33.7408	-118.27839	Replace existing FACP, install new FA devices. (1) FACP, (133) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14569	16041-10000-11720	12737 N GLENOAKS BLVD	91342	7	222B153   830	2508027025	QC2-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Info Complete	04/06/2016 12:00:00 AM	ADDRESS	34.30159	-118.44224	PLANCHECK FOR ENERGY. TOTAL AREA 914 SQ FT. TI FOR TWC OFFICE. B# 16016-10000-07416	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14570	15041-10004-00405	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.03365	-118.24048	((2/19/16: DELTA 6 CHANGES WHICH INCLUDE LIGHT RELOCATIONS AND T24 UPDATED ACCORDINGLY. PLAN CHECK ONLY))REVISIONS TO PERMITTED SET OF PLANS: XFMR TMS RELOCATED INSIDE BUILDING NEAR THE MAIN ELECTRICAL ROOM; MAIN ELECTRICAL ROOM REDONE TO ALLOW XFMR TMS TO BE NEARBY OUTSIDE  ELECROOM  ;ADDED PANELS LA2 AND LB2 (NEAR MAIN PANELS) FOR RECEPTACLE CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14571	15041-20001-27756	5416 N ROZIE AVE	91367	3	174B089   683	2047014015	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.16895	-118.65137	Expedited per customer request.PV1. Install roof mounted PV system sized 11 kW. Interconnected with main service panel. (48) KU265 Modules (1) PVI-6000 Inverter(1) PVI-5000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14572	10041-10000-04427	3650 W MARTIN LUTHER KING, JR BLVD UNITS 166-& 168	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM			PC Info Complete	04/14/2010 12:00:00 AM	ADDRESS	34.01118	-118.33649	PLAN CHECK FOR  RELOCATING EXISTING PANELS/TRANSFORMERS IN TENANT #166 AND #168. NO BRANCH CIRCUITS AND LOADS INSTALLED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14573	14041-20000-11429	6615 N ALLOTT AVE	91401	2	180B157   403	2329009038	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.19075	-118.42822	""" 0 permit fee due to solar ordniance ""PV1.  Install 11.00 kW roof-mounted PV system, interconnect with main service panel.  (44) modules.  (2) transformerless inverters: SolarEdge SE5000A-US"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14574	14041-20001-24796	7000 S HOOVER ST Unit #3	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #3.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14575	19041-10000-49586	844 S BROADWAY	90014	14	127-5A209 204	5144016060	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM			Corrections Issued	12/03/2019 12:00:00 AM	ADDRESS	34.04265	-118.25551	TENANT IMPROVEMENT FOR AN EXISTING CLOTHING RETAIL STORE. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 1,432 SFT.BULDING PERMIT: 19016-10000-18353	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14576	10041-10000-13131	459 S VERMONT AVE	90020	4	135B197   737	5502009011	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20, 2121.00	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	09/20/2010 12:00:00 AM	ADDRESS	34.06566	-118.29185	T24 lighting plan check for jack in the box restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14577	12041-20000-21096	19134 W ENADIA WAY	91335	3	183B121   239	2129003010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2012 12:00:00 AM			Reviewed by Supervisor	09/18/2012 12:00:00 AM	ADDRESS	34.20003	-118.55053	Plan check for SFD. Roof mount PV System. 4.8kW. Enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14578	11041-10000-09575	5933 W BOWCROFT ST	90016	10	117B173   121	4204008045	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			Verifications in Progress	05/18/2011 12:00:00 AM	ADDRESS	34.01927	-118.37733	PV SYSTEM FOR A SINGLE STORY COMERCIAL BUILDING.  MODIFICATION TO AN EXISTING APPROVED SET OF PLANS. approval is for load calculation not approval for pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14579	17041-10000-34997	135 S WESTERN AVE	90004	4	138B193  1213	5517002010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2115.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM			PC Approved	09/29/2017 12:00:00 AM	ADDRESS	34.072	-118.30931	PC for T24 only for photo studio TI. Installing new panel, circuits, lighting. Total area of 3410sqft. B# 17016-10000-19414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14580	12041-10000-28699	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	PLAN CHECK AND PERMIT FOR TITLE-24 PART 6, ENERGY.TI TO EXISTING WESTFIELD MALL: AMC AND PARKING STRUCTURE. METHANE ZONE. 353+13099+10207=23659SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14581	13041-10000-31168	17901 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.26504	-118.52367	TI remodel for new Starbucks in existing shell.  No change of use as per building permit.  New fixtures and wiring throughout.  Newly connected load not in excess of 400 A - Title 24 plan check  for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14582	16041-10000-09227	1464 S CENTRAL AVE	90021	14	121-5A211 168	5130011003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			04/19/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.02753	-118.24752	Plan check for power only to an existing apartment/retail comercial building. Scope includes upgrading the existing service to a 600A 120/240 3 phase, 4 wire service; and installing 15 new subpanels for apartment units, house panel, and retail spaces.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14583	18041-10000-13146	15279 W SUNSET BLVD #5-111	90272	11	129B125   591	4423016007	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.04702	-118.52515	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR TAKE-OUT RESTAURANT. SCOPE INCLUDE NEW INTERIOR NON-BEARING PARTITION. TOTAL AFFECTED AREA = 392 SQ. FT. NEW CONNECTED LOAD OF APPROX. 100A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14584	14041-10000-04430	1413 N L. RON HUBBARD WAY	90027	13	147B197   870	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.097	-118.29419	PLANCHECK FOR T24 ENERGY PER INSPECTORS REQUEST. ADDING 14 OUTDOOR LUMINAIRES AND 3 INDOOR LUMINAIRES IN AN OFFICE, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 14041-10000-02511	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14585	19041-20000-23989	8626 N LAUREL CANYON BLVD	91352	6	195B165   821	2634032011	RS-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.22667	-118.39794	PV1.  Install 10.85 kW DC / 9.90 kW AC roof mounted grid tied PV system.  (35) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14586	19041-10000-35841	3745 S CARDIFF AVE 1-2	90034	5	120B165   622	4313016049	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	03/16/2022 12:00:00 AM	ADDRESS	34.02592	-118.39703	FIRE ALARM SYSTEM FOR 6-STORIES 74 UNITS APARTMENT BUILDING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14587	18041-10000-19253	850 S OLIVE ST	90014	14	127-5A209 113	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04406	-118.25765	Energy plan check for juice bar on the 1st floor of a high rise building. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14588	15041-20001-01817	9410 N TOPANGA CANYON BLVD #200	91311	12	198B101   334	2746013038	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM			PC Approved	02/06/2015 12:00:00 AM	ADDRESS	34.2412	-118.60593	[[[2/6/15 PLANCHECK ONLY TO UPDATE THE T24 ONLY PLANS PER INSPECTORS REQUEST]]]]]]]PC FOR T24 ENERGY ONLY. NEW LIGHTING IN LOBBY AREA. LIGHITNG DESIGNED BY C-10 CONTRACTOR. INSPECTOR VERIFY PERMIT ISSUED TO C-10.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14589	18041-10000-08682	8999 N BALBOA BLVD	91325	12	195B133     8	2690006017	(Q)C2-1VL	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.23353	-118.50275	FULL PC FOR POWER AND ENERGY. TI TO TARGET RETAIL STORE. SCOPE INCUDES NEW PANELS, CIRCUITS, RECEPTICALS AND LIGHTING. TOTAL AFFECTED AREA IS 133409 SQ.FTB#18016-10000-03218	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14590	18041-10000-26335	700 S FLOWER ST 1900	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR TITLE 24 ENERGY ONLY FOR OFFICE TI (HIGH RISE BUILDING).SCOPE INCLUDES NEW CIRCUITS AND LIGHTS IN  SHARED CONFRENCE ROOM AND PANTRYTOTAL AFFECTED AREA 2698 SQ.FT B# 18016-10000-20004	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14591	15041-20000-30792	6119 N BUFFALO AVE	91401	2	177B157   574	2330014029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.18181	-118.43027	PV 1, 6 kWAC PV array,  (2) inverter  PVI-3.0-OUTD-S, (30) modules: #KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14592	15041-30001-37291	10300 W WILSHIRE BLVD	90024	5	135B157   117	4327013027	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	34.06768	-118.42561	Expedite fees only.      Installation of new roof mounted solar PV array on existing hotel.  Total system size = 120 kWac.  System consists of 5 identical 24 kWac inverters with 97 modules each.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14593	16041-10001-23085	1000 E WASHINGTON BLVD Unit 105	90021	9	121-5A211 373	5131008048	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Issued	09/23/2016 12:00:00 AM	ADDRESS	34.0256	-118.2533	09/23/2016 Changes to an approved set of plans. Changes include additional 5 exhaust fan. Changes apply to Delta 2 only. ((((((TI to (E) laundromat in (E) commercial single-story retail building.  Greater than 400 A of newly connected load.  Plan check for power and energy. 3170 sq ft))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14594	19041-10000-44936	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Issued	03/06/2020 12:00:00 AM	ADDRESS	34.10299	-118.25902	NEW ROOF MOUNTED 134.85KW PV SYSTEM WITH 310 PV PANELS TWO CENTERAL INVERTER ON A COMMERCIAL BULDING.0$ FINAL FEE PER AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14595	18041-10000-31785	10250 W SANTA MONICA BLVD 2460	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR POWER AND ENERGY. TENANT CORE AND SHELL IN SUITE # 2460 OF CENTURY CITY WESTFIELD MALL.1,022 SQR FT. BLDG PERMIT: 18016-10000-26068.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14596	16041-20001-03714	4825 N NEWCASTLE AVE	91316	5	168B125   386	2181029024	R1-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	34.15706	-118.52526	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.21 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14597	12041-20000-27821	16542 W VENTURA BLVD	91436	5	168B137   369	2284005025	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	12/28/2012 12:00:00 AM	ADDRESS	34.1576	-118.49393	Change to lighting, and receptacles for an existing restaurant.  Load is less than 400 amps and occupancy load is less than 99 people per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14598	17041-20000-44953	9301 N TAMPA AVE Space 169	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	02/28/2018 12:00:00 AM		Issued	02/28/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Interior tenant improvement in (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14599	11041-10000-15643	530 W 27TH ST # 104	90007	9	121-5A203  98	5123018033	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.0269	-118.27607	"T.I. for ""Five Guys"" restaurant.  (1st lease on new space)CHANGE USE AND TENANT IMPROVEMENT FOR A NEW BURGER RESTAURANT WITHIN A MIXED USE PROJECT; TENANT SPACE IS LOCATED AT THE GROUND FLOOR TYPE 1A COMMERCIAL OCCUPANCY ( A-3, B OR M) WITH ADJACENT PARKING (S-2) OVER 1 LEVEL TYPE 1A SUBTERRANEAN <SEE COMMENTS>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14600	12041-10000-13675	1505 N EDGEMONT ST	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM			Corrections Issued	07/25/2012 12:00:00 AM	ADDRESS	34.09843	-118.29637	TENANT IMPORVEMENT TO (E) MEDICAL CLINIC, WORK INCLUDES REMOVE AND REPLACE EXISTING FLUOROSCOPY (X-RAY) EQUIPMENT AT BASEMENT LEVEL, LIGHTING CHANGES, AND NEW RECEPTACLES.  FULL PLAN CHECK.   NOT STATE LICENSED, NOT CHECKED FOR OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14601	13041-10000-30717	621 S MANSFIELD AVE	90036	4	135B181   655	5507021004	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.06438	-118.34089	PV1, ROOF-MOUNTED SOLAR INSTALLATION INTERCONNECTING WITH (E) 200A MAIN.SYSTEM SIZE IS 8.175 KW DC WITH (25) MODULES (SUNPOWER; SPR-327NE-WHT-327W ) WITH (1) SUNPOWER SPR-7501F01UNI INVERTER, NEGATIVELY GROUNDED SYSTEM. 5 TOTAL STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14602	18041-20000-44572	20179 W RINALDI ST SUITE #150	91326	12	210B113   290	2701100007	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.27523	-118.57313	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first time tenant to a restaurant. Total lighting area = 5,648 sq. ft.Note: Building application has been generated under 18016-10000-36665	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14603	18041-10000-43523	1841 N GAFFEY ST C	90731	15	024B197    78	7442022021	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	33.7616	-118.2932	REMOVE HID INDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14604	12041-10000-18858	11500 W NATIONAL BLVD 1-18	90066	11	120B153   778	4250013012	RD1.5-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Apartment			08/10/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.02428	-118.4351	This is a new 18 units apt. fire alarm, 2 story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14605	15041-20000-02493	17555 W COMMUNITY ST	91325	12	192B129   210	2787015006	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.22287	-118.5169	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 8.8kW (3.8+5). Ungrounded system. (28) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14606	13041-20001-27741	560 N AMALFI DR	90402	11	123B129   114	4408021005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.03601	-118.51291	((((EXPEDITE FEES))))PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 7.0KW. 28 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14607	15041-20000-16131	17902 W RAYMER ST	91325	12	195B129   685	2787035057	R1-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.22691	-118.52338	Installation of roof mounted solar PV array.  Total system size = 10 kWac (standard plan used).  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14608	14041-10000-12290	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM ROW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14609	14041-10000-02222	1034 W 50TH ST	90037	9	111B197  1159	5017026059	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			Corrections Issued	01/27/2014 12:00:00 AM	ADDRESS	33.99764	-118.29285	pc for power only. NEW 800A SERVICE FROM 600A. ALL LOADS (E) PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14610	10041-10002-01492	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Closed	07/18/2014 12:00:00 AM	ADDRESS	34.09676	-118.29487	This permit covers the change of 800 amps BRK at the gent set contril panel to 600 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14611	14041-20000-31525	20221 W BALTAR ST	91306	3	189B113   303	2107017130	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.21655	-118.57388	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size: 7.2kW (3.6+3.6). Ungrounded system.34 255W pv modules across 4 strings (7+10 on inv1, 7+10 on inv2).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14612	18041-20000-33409	20615 W CHESTNUT CIR #281	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	04/13/2019 12:00:00 AM	ADDRESS	34.29287	-118.58362	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14613	16041-20002-11634	1213 N DOUGLAS ST	90026	1	138A211    25	5405002004	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.07399	-118.25251	PV1.  Install 5.2 kW roof mounted solar system.  (16) modules with a transformerless 5kW rated central inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14614	19041-10000-01213	1550 N SAN PABLO ST	90033	14	135A225   142	5202001009	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	01/29/2021 12:00:00 AM	ADDRESS	34.06359	-118.20244	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 200UNIT 5 STORY HOTEL WITH RESTAURANT, RETAIL, AND POOL. SCOPE OF WORK INCLUDES NEW 4000 AMPS SERVICE, 277/480 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 53972 SQFT. LD# 17010-10000-04213	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14615	17041-10001-24070	12568 W TIBBETTS ST	91342	7	228B161   754	2580004012	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.31876	-118.40694	**Fee expedite per applicantInstall new rooftop solar system 24kW AC, (69) AC modules, with new 125A subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14616	14041-20001-13668	16936 W SUPERIOR ST	91343	12	201B133   392	2686025033	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.24727	-118.50143	Expedite per customer request7.24KW PV1 roof-mounted system wtih (32) Yingli YL250P modules, and (2) Power-One-PVI-4.2 and 3.0-OUTD-S-US transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14617	15041-20000-27572	8635 W 3RD ST west tower	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.07373	-118.38073	Plan check for title 24 only. Project is an existing commercial high-rise building. Project scope is a tenant improvment to the corridors and lobbies for 1 through 11. Total indoor area: 16338 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14618	13041-10000-05865	5337 S ARLINGTON AVE	90043	8	108B189   463	5005004023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	33.99404	-118.31832	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 1.7 KW. 8 PANELS AND MICROINVERTERS. [MICROINVERTER: ENPHASE M215-60-2LL-S2X] [SOLAR  MODULE: YINGLI YL245P-29B].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14619	17041-10000-46397	722 E 40TH PL	90011	9	115-5A207 316	5114007040	RD2-1	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2017 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.01005	-118.26294	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac. (11)MODULES-HANWHA Q-CELL. Q PEAK-G4.1 300(11)OPTIMIZERS- SOLAREDGE P320(1)INVERTER-SOLAREDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14620	17041-20001-39937	7507 N LURLINE AVE	91306	3	186B109   448	2113009004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.20666	-118.58424	expeditepv1install roof mounted pv system sized 6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14621	17041-10000-36693	19600 W PRAIRIE ST	91324	12	198B117   252	2761035012	[Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Info Complete	01/31/2018 12:00:00 AM	ADDRESS	34.23894	-118.56048	(((PC TO VERIFY THAT ALL POWER CIRCUITS AND EQUIPMENT CIRUCUITS ARE SHOWN ON PLANS))PC for power and energy for new four story assisted living building with 96 units and one level of subtarrenean parking. Installing new 4000A 120/208V service, new panels and a 200kW emergency generator. Total indoor area of 119962sqft and 20887sqft oudoor. PC to ask for panel schedule for all P1 panels.Building 16010-10000-04789.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14622	16041-10000-00712	1132 E 55TH ST	90011	9	108B209   803	5104017014	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	33.9929	-118.25552	PV1, rooftop solar installation 3.6 kW AC(14) LLE-6M-260(1) PVI-3.6-TL-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14623	07041-10001-30616	5031 N FAIR AVE	91601	2	171B173  1095	2353012016	R4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			03/05/2012 12:00:00 AM			PC Approved	04/09/2012 12:00:00 AM	ADDRESS	34.1617	-118.37478	CHANGE LIGHITNG SYSTEM FOR EACH FLOOR, PUBLIC AREAS ONLY: CORRIDORS AND GARAGES.BUILDING HAS EMERGENCY GENERATOR. TITLE 24 COMPLIANCE. NO CHANGES TO POWER SYSTEM. New 308 units apartment building.  Fire alarm variance has been filed.  Fees for Apt smoke detectors TBD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14624	19041-10000-24889	1247 E 6TH ST	90021	14	126A215   327	5164009024	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	01/06/2020 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	34.03829	-118.2374	PC for T24 only, scope of work is adding new lighting and controls, and power for fire damaged equipment. Total affected area is 8570 sqft. B# 19016-20000-14594	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14625	11041-10001-13752	3425 N GREEN VISTA DR	91436	5	159B133   163	2287010071	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	34.1327	-118.499	New 16.7 KW pv solar roof mounted system. for a single family resisdence.  All clearances have been obtained via permit # 11041-40000-13752.  Regular plan check.  All wiring shall be in shade, and service is rated 400 ampere with 200 ampere main circuit. <<<<<<ROOF MOUNT SOLAR PV SYSTEM>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14626	17041-10000-18351	7852 S BOEING AVE	90045	11	099B169   651	4106027006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			Reviewed by Supervisor	06/13/2017 12:00:00 AM	ADDRESS	33.96744	-118.38752	PC FOR BATTERY BACK UP SYSTEM. SYSTEM IS UTILITY INTERACTIVE. RATED 5.8KW AC. TOTAL CAPACITY - 13KWH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14627	18041-10002-48684			4	135B185   283	5507014018	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	PIN	34.06630095	-118.33753926	"DELTA ""1"" CHANGES TO THE APPROVED PLANS FOR ADDING NEW (DC) & (AC) DISCONNECTS.<<<Plan check for PV1 10KW AC / 9.75 KW DC roofmounted system with (30) modules, (1) central inverter, (3) energy storage systems, and (3) subpanels interconnecting through a new 200-Amp service.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14628	10041-10000-20466	1650 N SCHRADER BLVD	90028	13	148-5A187 184	5547016005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM			PC Approved	10/14/2010 12:00:00 AM	ADDRESS	34.10103	-118.33236	TI TO THE LIGHTING SYSTEM IN  ABAR/RESTAURANTPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14629	14041-20000-29422	19765 W RINALDI ST B	91326	12	210B117   380	2701040039	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.27504	-118.56378	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING. ADDING LIGHTING TO EXISTING POWER EQUIPMENT.  2969 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14630	13041-20000-24738	21700 W OXNARD ST Suite 1400	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.17901	-118.60179	T24 FOR EXISTING HIGHRISE OFFICE. SCOPE OF WORK ON THE 14TH FLOOR SUITE 1400. 12588 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14631	14041-10000-27132	1925 S BUNDY DR Bldg 2	90025	11	123B149   330	4259018014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.0346	-118.45665	New fire warning system for building 2. 1 panel 3 booster power supplies and 116 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14632	10041-10000-07445	3163 W PICO BLVD	90019	10	129B193  1275	5080004017	C4-1	Central	Wilshire	Olympic Park		2131.00, 2213.01	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.04733	-118.31126	TI IN AN EXISTING OFFICE AREA OF A BODY SHOP.  REF.#10042-10000-06841.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14633	13041-10000-24211	808 S LOS ANGELES ST	90014	14	127-5A211 318	5145013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.0416	-118.25247	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For retail. 3 new lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14634	11041-10000-17401	1071 W 190TH ST	90248	15	060B197   539	7351029002	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	33.85848	-118.29445	remodeling of 2-stories office buildingplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14635	19041-20000-50654	303 S GAFFEY ST	90731	15	018B197  1550	7451020033	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	33.74122	-118.29251	Power and lighting for commercial space tenant improvement.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14636	18041-20000-09369	9030 N OWENSMOUTH AVE	91304	3	195B105    34	2779018012	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.23452	-118.60151	Change of use from warehouse to commercial kitchens.  Building permit under 18016-20000-07799.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14637	16041-10001-33244	4000 N EAGLE ROCK BLVD	90065	1	156A217   245	5472001057	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.11994	-118.22853	10/03/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include replacing lighting fixtures. Note: Original application is under PCIS#16041-10000-33244(((((TITLE 24 FOR EXISTING LOW RISE BUILDING. CHANGE OF USE FROM RETAIL TO VETERINARY CLINIC. TOTAL SQ. FT. 1839	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14638	11041-10000-14385	800 S FIGUEROA ST STE 101	90017	9	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.04771	-118.26116	CHANGE OF USE FROM CONVENIENCE STORE TO RESTAURANT IN SUITE #101 ON THE FIRST FLOOR.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14639	15041-20000-10059	8446 N RANCHITO AVE	91402	6	192B153   298	2637032010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.22482	-118.43663	Plan check for PV1 roof mounted system with 6.0kW and 24 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14640	11041-10002-20833	2915 W LOS FELIZ BLVD	90039	13	157-5A207 373	5594006021	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM			Verifications in Progress	05/16/2012 12:00:00 AM	ADDRESS	34.12679	-118.26282	T-24 lighting plan check for new Chase Bank.  Interior and exterior lighting.  Total load is 348.68 and occupancy load is less than 99(((((( changes made to previously approved set,  rearranging the fllor plan.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14641	18041-10000-11525	6949 N TOPANGA CANYON BLVD	91303	3	183B101   447	2024003001	(WC)TOPANGA-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.19695	-118.60618	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14642	11041-10000-12763	7411 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/03/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of 1 elevator unit in Maintenance Bldg at LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14643	14041-10000-25023	3930 N LAUREL CANYON BLVD 1-69	91604	2	162B165   407	2369019032	R4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM			Reviewed by Supervisor	11/05/2014 12:00:00 AM	ADDRESS	34.14177	-118.39441	PV2, INSTALL 34935 W DC ROOF-MOUNTED SOLAR ARRAY ON A APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL.(137) MODULES: CANADIAN SOLAR CS6P-255P(3) INVERTER: SMA AMERICA SB8000US-12 AND SMA AMERICA SB6000US-12	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14644	19041-10000-31320	5220 W WASHINGTON BLVD	90016	10	126B177   869	5063001035	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Issued	10/02/2019 12:00:00 AM	ADDRESS	34.04128	-118.35472	0$ due to Assably bill 1444PC FOR PV-2 SOLAR SYSTEM. SYSTEM SIZE 30KW. 90 MODULES (CANADIAN SOLAR CS6K-305MS),   4 INV (7700TL - US), 2-100A DISCONNECT SWITCH.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14645	17041-20000-16264	15250 W VENTURA BLVD Ste 720	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	05/16/2017 12:00:00 AM	ADDRESS	34.15351	-118.46549	TI to (E) commercial office space.  Plan check for energy.  1253 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14646	19041-20000-32298	8420 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14647	15041-10000-25655	6245 W WILSHIRE BLVD	90048	5	135B177   481	5510027014	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.06356	-118.36478	PC FOR POWER AND ENERGY FOR A 20 STORY HIGH RISE MIXED USE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14648	17041-20000-22160	22330 W MAYALL ST	91311	12	204B101   433	2745011046	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	09/16/2017 12:00:00 AM	ADDRESS	34.25388	-118.61379	Plan check for roof-mounted solar pv system, SFD.10.4kW ungrounded system. (38) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14649	15041-10000-11581	2625 W 6TH ST	90057	1	135A201   185	5155028022	C2-2	Central	Westlake			2087.20	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.06242	-118.28093	TI for (E) restaurant space.  Lighting and receptacles.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14650	18041-10000-43979	718 S HILL ST 7TH FLOOR	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.04527	-118.25477	PC FOR A TI-FIRST TIME TENANT (POWER AND ENERGY) FOR A  LOW RISE OFFICE BUILDING. 7TH FLOOR. SCOPE INCLUDE NEW CIRCUITS, RECEPTICAL  AND LIGHTING. TOTAL AFFECTED AREA IS 5847 SQ.FTB# 18016-10002-03643	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14651	15041-10000-11882	7123 N ETIWANDA AVE	91335	3	183B125   303	2125003031	[Q]R3-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Apartment			04/21/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Expired	05/16/2017 12:00:00 AM	ADDRESS	34.19995	-118.53188	New fire alarm system for an existing 2-story 29-unit apartments; scope includes (1) fire alarm panel, and (40) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14652	14041-10000-18648	1627 N FRIES AVE	90744	15	036B205   333	7421010026	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	33.79616	-118.26626	Install roof mounted solar PV system on existing residential building.  Total system size = 5 kW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14653	16041-20000-40164	11335 W MAGNOLIA BLVD C1	91601	2	171B173   586	2350017047	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.16504	-118.37847	PLANCHECK FOR T24 ENERGY. INDOOR AND OUTDOOR LIGHTING. CHANGE OF USE TO BEAUTY SALON.  1325 SQFT. UNIT C-1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14654	17041-10000-00288	1722 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   327	5021032023	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.01068	-118.30985	PC for energy only. Remove HID outdoor fixutres and replace with new LED fixtures. Total area:2,575.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14655	19041-20000-35164	6509 W DE LONGPRE AVE	90028	13	147A187   250	5546014016	C2-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.09625	-118.33056	Plan check for New fire alarm system for  commercial building. Total fire alarm devices: 70 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14656	07041-10001-28969	440 S OCCIDENTAL BLVD	90057		135A201    58	5155011011	R4-1		Westlake		YES		Electrical	Electrical	Apartment			04/16/2010 12:00:00 AM			PC Approved	04/16/2010 12:00:00 AM	ADDRESS	34.065	-118.28357	REVISED PERMITTED SET OF PLANS  :  IN THE LOBBY AREA ON THE GROUND LEVEL, THE  INTERIOR WALLS OF A MEETING ROOM WAS REMOVED TO INCREAS THE AREA OF THE LOBBY. A FEW LUMINAIRES WERE RELOCATED/ REMOVED AND 1 EA TYPE D WAS ADDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14657	10041-10000-06139	431 S HEWITT ST	90013	9	127-5A215 313	5163022021	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	10/20/2010 12:00:00 AM	ADDRESS	34.04264	-118.23534	Plan check T-24 Energy for warehouse/office spaces in existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14658	18041-20000-40132	13788 W FOOTHILL BLVD unit a	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.30953	-118.43339	Plan check for Title 24 only in existing space T.I. to Martial Arts Studio, office, bathroom. Total area: 2778 sq ft. B#18016-10000-234870	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14659	13041-10000-16805	3601 S TROUSDALE PKWY 4TH FLOOR	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.02017	-118.28558	4th floor commercial low-rise TI.  Newly connected load < 400 A.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14660	19041-20000-21801	18137 W MARILLA ST	91325	12	201B125   252	2764018021	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.24741	-118.52893	Plan check for battery energy storage system install in to existing PV System. Energy Storage System: 13.5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14661	16041-10001-37767	10700-11000 S PERSHING DR	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	Yes	9800.28	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	33.93748	-118.43218	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REMOVAL OF EXISTING 100A BREAKER AND REPLACE WITH 3(20A) & 1(40A) BREAKER FOR ALL EXISTING LOAD. ORIGINAL PERMIT PC for new 800A service and 3 pumps. this is for pump station at LAX	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14662	13041-10000-12248	1828 E CESAR E CHAVEZ AVE 6006	90033	14	130-5A221 325	5174008022	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.05014	-118.21571	pc for power and energy. 1st time tenant for medical building.  suite 6006. non-oshpd3. diabetes clinic.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14663	17041-10000-18661	835 W BLOOM WALK Ste 168	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.01948	-118.2876	Title 24 plan check only.  T.I. to existing university biology research lab facility.  One new 125 amp panel and new lighting + receptacle + EF loads.  Total area = 665 sq. ft.       Building permit #17016-10000-07210	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14664	11041-20000-23680	127 S SAN VICENTE BLVD Bulletin-73-CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta #73-CS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14665	19041-10000-06385	2221 S WESTERN AVE	90018	10	123B193   290	5058009041	C2-1-O, P-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.01	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	07/23/2021 12:00:00 AM		Permit Finaled	04/16/2024 12:00:00 AM	ADDRESS	34.03588	-118.30923	FULL PLAN CHECK FOR A PROPOSED 5 STORY, MIXED USE 54 UNIT APARTMENT, RETAIL AND BASEMENT GARAGE. PROJECT HAS PORTION  AFFORDABLE HOUSING; SCOPE INCLUDES A 3000-AMP 120/208V 3PHASE 4WIRE WITH (12) TYPICAL UNITS LOCATED IN THE METHANE ZONE.Note to plan checker. applicant comes with a precut check 100 ckt short.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14666	15041-10000-30452	1461 S LA CIENEGA BLVD	90035	5	129B173   458	4303033034	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM			Corrections Issued	09/15/2015 12:00:00 AM	ADDRESS	34.0512	-118.37633	TI  INTERIOR & EXTERIOR; MAJOR REMODEL TO (E) RESTAURANT (Yoshinoya)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14667	14041-20000-23372	1455 W 3RD ST	90026	13	133-5A207 258	5153028008	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	PIN	34.05914991	-118.26316109	CHANGE OF USE TO BAKERY. LOAD LESS THAN 400A. EXPANDED EXISTING CUSTOMER SERVICE AREA TO NEW AREA OF TI. PLAN CHECK FOR ENERGY ONLY. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14668	18041-10000-42415	10741 W MOORPARK ST	91602	4	165B177   321	2423006020	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.15051	-118.36506	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14669	19041-10000-40648	8475 S VERMONT AVE	90044	8	097-5A199 166	6033025902	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	02/24/2021 12:00:00 AM	ADDRESS	33.96111	-118.292	Full plan check for a T.I. Scope includes modification of an exisitng service panel, adding new back up generator, new panels and other associated equipment with a toal lighting area of 16,750 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14670	15041-20000-31806	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM			PC Info Complete	12/18/2015 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for power only.  Replacement of 522 kVA chiller and addition of two water pumps + one exaust fan.  Alternate 1 or  alternate 2 can be install.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14671	18041-20000-38381	1718 N LAS PALMAS AVE	90028	13	148-5A185  78	5547009024	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	11/20/2020 12:00:00 AM	ADDRESS	34.10226	-118.33601	Plan check for a fire alarm system for a 6 story apartment building. Fire alarm system consists of (1) FACP and (528) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14672	19041-10000-05854	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.04771	-118.44481	T-24 ONLY FOR A TI OF THE GROUND FLOOR LOBBY AREA IN A HIGHRISE. SCOPE INCLUDES NEW LIHTING AND CONTROLS ON EXISTING CIRCUITS. TOTAL AFFECTED AREA IS  4037 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14673	17041-20000-34748	15760 W VENTURA BLVD suite 1020	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. 2845 SQFT. HIGHRISE. SUITE 1020	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14674	19041-30000-47582	5110 N WHITSETT AVE 1-15	91607	2	171B165   793	2356020025	R1-1, RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	11/10/2020 12:00:00 AM	ADDRESS	34.16343	-118.40506	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS 75 DEVICES WITH A NEW FIRE ALARM CONTROL PANEL AND A NEW POWER SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14675	14041-10001-06008	20315 W NORDHOFF ST	91311	12	195B113    61	2781001019	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	34.23201	-118.57642	DELTA 2 REVISIONS TO PERMITTED SET OF PLANS-THE 2 EA 30KVA XFMRS REPLACED WITH 1 EA 75KVA; USING EXISTING PANEL DP TO SUPPLY PANELS P1,P2,P3,P5,P6, AND P7((((((((((PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE FROM WAREHOUSE TO CHILDREN PLAY GROUND. SERVICE IS EXISTING. FIRE ALARM UNDER SEPERATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14676	17041-20000-01127	2106 N CEDARHURST DR	90027	4	150B201   229	5591007001	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.11024	-118.28482	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 175A. 3.8kW ungrounded system. (13) 290W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14677	17041-10000-14858	10250 W SANTA MONICA BLVD ste 1580	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	T24 ONLY FOR INTERIOR SIGN LIGHTINNG(NEON). COMMERCIAL BUILDING ( CENTURY CITY MALL) TOTAL AREA < 1000 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14678	13041-10001-31237	1038-1048 S MARIPOSA AVE	90006	1	129B197   387	5078016016	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.05151	-118.2988	"(((((((((((((((((     1-113-15      M.Z    change of service from 120/208 to120/240 3 phase 4 wire system.    )))))))))))))))))))))))))))FULL POWER PLAN CHECK FOR A NEW 32 UNIT APARTMENT BUILDING. PLAN CHECK IS FOR POWER AND ENERGY. NEW 1600A 120/208 3PH 4WIRE ""MSA"". TOTAL ILLUMINATED AREA TO BE 38,434 SQ FT (INDOOR + OUTDOOR). 5 FLOORS FROM GND, APPROXIMATELY 9 DIFFERENT UNIT TYPES PER ARCHITECT. (7) 1200A SWITCHBOARD SECTIONS & (32) SFD SMOKE DETECTORS WERE ACCOUNTED FOR AND CHARGED."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14679	12041-10000-12365	21801 W OXNARD ST	91367	3	177B105    56	2146005179	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	08/08/2012 12:00:00 AM	ADDRESS	34.17941	-118.60306	Plan check T-24 Energy and emergency lighting for remodel of existing food service area within food court.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14680	15041-20001-10041	12452 W OSPREY LANE #2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	Supplemental application for expedite fees.Installation of new roof mounted solar PV array on 3 unit apartment building (triplex).  Each unit panel is fed by a seperate inverter (3 inverters total).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14681	10041-10000-06086	20935 W WARNER CENTER LANE Suite B-bldg F1	91367	3	174B109     2	2149017004	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	04/05/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.17505	-118.5896	Alteration of an open area office space- add partitions to form 4ea private offices and remodel remaining open area for support areasplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14682	15041-10000-22902	19801 W NORDHOFF PL # 110	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.23568	-118.56464	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISITNG PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 13206.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14683	14041-10000-21980	3249 N CAHUENGA BLVD WEST	90068	4	159B181   746	2429010004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.12921	-118.34863	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. EXTERIOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14684	15041-20000-03724	1747 W BROWNING BLVD	90062	8	114B193   107	5035009019	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.01201	-118.31049	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.25KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14685	17041-20000-25108	2805 S FIGUEROA ST	90007	9	121-5A203 158	5123014021	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.02559	-118.27788	Plan check for energy only. TI to restaurant (Subway). New lighting - 895sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14686	18041-10003-24837	4141 W SANTA MONICA BLVD	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	"DELTA ""1"" Changes ONLY to T-24 approved plans in Basement, 1st Floor (Restaurant) and Pool Deck area. change includes adding 2 exit signs only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14687	13041-10000-32361	19041 W CELTIC ST	91326	12	210B121   615	2718011001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.2693	-118.54777	PV1, Install 9.25 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverters Solaredge SE5000A-US and Solaredge SE3800A-US . 37 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14688	13041-10001-24086			4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM				"CHANGES MADE TO PREVIOUSLY APPROVED SET.  A) ADDITION OF PV TO EACH RESIDENTIAL UNITB) REMOVE LIGHT FROM GARAGEC) ADDITONAL J BOXES IN RESIDENTIAL UNIT FOR FANS, LIGHTS, ETC.D) REMOVE LIGHT (FL) AND REPLACE WITH INCANDESCENT WITH DIMMER IN HALLWAYS(((400A UNDERGROUND PULL SECTION. PLAN CHECK FOR POWER .CONSTRUCT BUILDING 4 OF 6 WHICH INCLUDES:  2- ""B2"" UNITS, 4-""B3"" UNITS- 6 UNITS TOTAL. BUILDING REFERENCE APP # 13010-10000-02662)))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14689	13041-10000-16426	750 S LAMAR ST IWTP-SLUDGE CP	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (9.) IWTP, AND THE SLUDGE CONTAINER CANOPY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14690	12041-10004-28962	905 E 2ND ST	90012	14	129A215   180	5163004006	(T)(Q)C2-2D	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.04729	-118.23499	CHANGES TO APPROVED SET. CHANGES NOTED DELTA  - RFI 752 - UPDATE PANEL AND FLOOR PLAN TO SHOW SEWAGE EJECTION AND SUMP  PUMPS AT 208 VOLT PANELS. NO OTHER CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14691	16041-10000-11780	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	PC FOR ENERGY, MEDICAL OFFICE. COMMON AREA.  REPLACING EXISTING HID LIGHTING FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 12122 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14692	16041-20000-11634	1213 N DOUGLAS ST	90026	1	138A211    25	5405002004	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.07399	-118.25251	PV1.  Install 5.2 kW roof mounted solar system.  (16) modules with a transformerless 5kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14693	18041-10001-10568	700 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM			PC Approved	05/04/2018 12:00:00 AM	PIN	33.94153561	-118.3984113	CHANGES TO AN APPROVED SET UNDER DELTA 1. SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTICALS. REVISING TITLE 24 CALCULATIONS, REVISING LIGHTING FLOOR PLANS, AND EMERGENCY PHOTOMETRICS. TOTAL AFFECTED AREA INCREASED FROM 405 TO 820 SQ.FT B#18016-10000-03226	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14694	13041-20000-24485	6360 W WILSHIRE BLVD #510	90048	5	135B173   882	5088014007	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.0634	-118.36754	TI FOR EXISTING DENTAL OFFICE. FULL PLAN CHECK REQUIRED FOR POWER AND ENERGY. 1150SQRFT.((no change of use))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14695	19041-10000-25546	555 W 5TH ST 48TH FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR T24 ONLY, TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. REPURPOSE BRANCH CIRCUITS FOR THIS PROJECT FROM (E) PANELS. NO CHANGE IN EXISTING USE OR OCCUPANCY.B# 19016-10000-19176	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14696	15041-30000-43241	1836 S COLBY AVE 1-49	90025	11	126B149   704	4261024096	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.04086	-118.44902	Installation of new fire alarm system in 49 unit 4 story apartment building.  Total system size = 199 devices + 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14697	15041-20004-01844	416 W 8TH ST	90014	14	127-5A209  58	5144018030	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.04471	-118.25646	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 12. CHANGES FIRE PUMP CONNECTION FROM GENERATOR SIDE TO SINGLE BREAKER DIRECTLY OFF GENERATOR.APPLICATION IS PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14698	15041-10000-13661	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM			Reviewed by Supervisor	06/04/2015 12:00:00 AM	PIN	33.93847109	-118.41935625	PHASE 2 OF TAXIWAY T CONSTRUCTION. ADDING NEW TAXIWAY LIGHTING AND SIGNAGE  FED FROM   EXISTING RON APRON POWER DISTRIBUTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14699	17041-20000-38052	660 S VETERAN AVE	90024	5	135B149   467	4363013038	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			10/23/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.06501	-118.45379	"""0$ permit fees due to senate bill 1222""Plan check for solar pv system, roof-mounted array on apartment building.Total system size: 32.4kW ungrounded.(2) 9kW SolarEdge inverters.(1) 14.4kW SolarEdge inverter.(125) 275W pv modules.(125) 300W power optimizers."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14700	12041-20000-29400	4114 N HAYVENHURST AVE	91436	5	165B137   506	2291013022	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2012 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	ADDRESS	34.14543	-118.49779	PV-1. Plan check for enphase system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14701	10041-20002-02966	440 S VERMONT AVE Market	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Delta 4 revision to approved plans. Changes to lighting, added new panel and xfmr to supply tracklighting, and relocate ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14702	13041-20001-25070	19332 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.23457	-118.55484	"((CHANGES MADE TO APPROVED SET. RUNNING 2-2"" CONDUITS INSTEAD OF A 4"" AND CHANGING SECTION FROM 400A TO 200A. BUS SIZE HAS NOT BEEN CHANGED))INSTALLING TWO 400A SECTIONS TO NEW 800A SERVICE. RUNNING CONDUITS WITH CONDUCTORS TO SHELL BUILDING. NO LOAD IS TO BE ADDED AT THIS TIME. THE FUTURE TENANT REQUIRES FULL PLAN CHECK."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14703	19041-20000-29675	11949 N WOOD RANCH ROAD	91344	12	216B129   233	2601066016	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.28804	-118.52241	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.7KW DC/11.5KW AC. SCOPE OF WORK INCLUDES (36) PV MODULES WITH INTEGRATED MICROINVERTERS, AND A NEW 100A SUBPANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14704	17041-20000-10650	8256 N HAVEN LANE	91325	6	192B133   534	2204001048	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.2207	-118.5072	pv1install roof mounted pv system sized 3.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14705	16041-10000-43692	10250 W SANTA MONICA BLVD # 1900	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Urban Decay"" Ste. 1900.  Install new Xrfmr, and  panels, total area 1,055 sq.ft** new demand load 44A to DB-ELA 43"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14706	18041-10000-24440	2600 S VERMONT AVE 104/105	90007	8	123B197   900	5055005033	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.03252	-118.29135	PC FOR ENERGY ONLY, CONVERT (2) EXISTING COMMERCIAL RETAIL SUITES INTO (1) USBANK BRANCH; SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUITS. TOTAL SQ. FT. 1689.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14707	10041-20000-16153	11800 W VENTURA BLVD	91604	2	162B169   323	2369027025	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.14185	-118.38938	animal hospital renovation energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14708	10041-10000-20424	732 E 10TH ST 101	90021	9	124-5A211 195	5132011030	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	10/15/2010 12:00:00 AM		Permit Finaled	11/10/2010 12:00:00 AM	ADDRESS	34.03504	-118.25099	First tenant in commercial space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14709	19041-10000-47072	384 WORLD WAY SPACE M37	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			Verifications in Progress	03/10/2020 12:00:00 AM	ADDRESS	33.94339	-118.40887	First Time Tenant in Space #M23 (ROCKET CHEFS) in LAX. Installing Panel, Loads, Lights, Etc. Full Plan Check for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14710	12041-10000-21531	418 N EAST EDGEWARE ROAD	90026	1	136-5A209 348	5160020051	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			Corrections Issued	09/11/2012 12:00:00 AM	ADDRESS	34.06619	-118.25477	TI in an existing comercial. EPC is for T24,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14711	17041-20001-35673	122 S ST ANDREWS PL	90004	4	138B193  1132	5516025029	R3-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.07248	-118.31118	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.44 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14712	14041-10000-11985	3848 S HILL ST	90037	9	117A203   266	5122038027	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.01326	-118.27879	Remove HID light fixtures and replace with new flourescent fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14713	14041-10000-03238	2268 N BEN LOMOND DR	90027	4	150B201   123	5591005003	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.11078	-118.28247	PV1.  Installation of 4.5 kW DC roof-mounted PV system, interconnect with main service panel.  18 modules: Renesola JC250M-24/Bb.  Microinverter standard plan: Enphase M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14714	15041-20000-17840	16616 W DEARBORN ST	91343	12	198B137   809	2687025010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.23741	-118.49436	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (23) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14715	16041-10000-09998	3151 N FARNSWORTH AVE	90032	14	141A237    32	5220009025	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Expired	04/23/2018 12:00:00 AM	ADDRESS	34.08238	-118.16571	NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.4KWac(71)MODULES-SOLARCITY(2)INVERTERS-FRONIUS #PRIMO 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14716	19041-10000-08458	6333 W 3RD ST #750	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/14/2021 12:00:00 AM	ADDRESS	34.07157	-118.36014	PLAN CHECK FOR TITLE 24 ONLY FOR - TI WORK FOR (E) RESTAURANT OF 1336 SF  WITH (E) 665 SF  OF OUTDOOR PATIO DINING AREA AT FARMER'S MARKET. - TOTAL AFFECTED AREA = 1221 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14717	10041-20000-17426	16000 W VENTURA BLVD #1200	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	10/06/2010 12:00:00 AM	ADDRESS	34.15584	-118.48164	energy plan check suite # 1200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14718	19041-10000-17486	888 S VERMONT AVE	90005	1	132B197   747	5077024043	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.05601	-118.29141	pc for new FA system. 1 new FACP and 204 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14719	14041-20000-01727	12265 W VENTURA BLVD SUITE 208-& 209	91604	2	162B165   111	2367017016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.14328	-118.40035	Change of use to Dental Office.  Install new branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14720	13041-10000-32994	4731 N TYRONE AVE	91423	2	168B153   465	2248002012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.1569	-118.44446	PV1, Install 10.5 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(2)Transformerless inverter(s): SolarEdge SE5000A-US. (42) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14721	15041-10000-05756	1000 W WILSHIRE BLVD Ste 2145	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM			PC Approved	02/27/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	Renovation to (E) tenant space in (E) commercial highrise building on the 21st floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14722	18041-20001-17728	3010 N SIERRA ST	90031	1	141A225   184	5209002016	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.08078	-118.20146	Changes to an approved set of plan, Changes include relocate inverter and disconnect. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14723	16041-20000-26825	21218 W ROSCOE BLVD	91304	3	192B105   663	2109002031	M2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.21968	-118.5943	New 210 kW fuel cell system, interconnected to (E) service 480/277V. Fuel Cell utility interactive.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14724	15041-10001-39546	23749 S PRESIDENT AVE	90710	15	042B193   554	7439004011	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	33.81007	-118.30407	[PC only] rooftop solar installation 3.6kW system.(19) KU2656ZPA(1) PVI-3.6-OUTD-SPermit under 15041-90000-39546	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14725	11041-20000-03357	10821-10823 N ZELZAH AVE Building D	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.26672	-118.52366	Plan check for 1600A service for Building D core and shell. Future tenants are Rite Aid and Sprouts.  New service, switchboard, feeders and 2 sump pumps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14726	15041-20000-02048	7251 N BALBOA BLVD	91406	6	186B133  1083	2227003***	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Expired	03/01/2017 12:00:00 AM	ADDRESS	34.20273	-118.50132	PV2Install a roof-mounted solar array on a 4-unit condo. Interconnect with individual unit panel, backfeed to 225A shared service.System size: 6kW. Ungrounded system.25 255kW pv modules across 3 strings (7 and 9+9 combined).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14727	19041-10000-53202	4938 W ROSEWOOD AVE 1-16	90004	4	141B193  1414	5522020025	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM	05/07/2020 12:00:00 AM		Issued	05/07/2020 12:00:00 AM	ADDRESS	34.07915	-118.31272	FULL PC FOR A NEW 600 AMP SERVICE, PANELS, CIRCUITS & OTHER LOADS IN AN APARTMENT BULDING.NOTE CHANGE OF ENGINEER AND CHANGE OF DESIGN IS RECORED UNDER 19041-10001-53202	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14728	17041-10000-08421	830 W WASHINGTON BLVD	90015	1	124-5A203  77	5124019001	[Q]C2-2-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.03615	-118.27644	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 15,675 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14729	14041-20000-18861	5350 N LOLETA AVE	90041	14	165A227   209	5691001002		East Los Angeles				1810.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	PIN	34.14463857	-118.19790508	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER. USING POWER OPTIMIZES. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14730	19041-20000-31301	1100 W 256TH ST Unit B	90710	15	036B197   954	7413011014	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.79177	-118.29609	Plan check for PV roof mounted system, PV system size: 2.64KW DC, 2.394KW AC with 8 PV Modules an 4 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14731	15041-10000-41662	12100 W WILSHIRE BLVD STE 1450	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	T-24, TENANT IMPROVEMENT TO EXISTING OFFICE SPACE TO ENLARGE INDIVIDUAL OFFICE SPACES AND (N) PARTITION WALLS, ADDING NEW RECEPTACLES AND LIGHTING. TOTAL SQ. FT. 4581.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14732	10041-20000-01171	930 W 34TH ST Bldg B	90089	9	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM			PC Approved	05/05/2010 12:00:00 AM	ADDRESS	34.02383	-118.28699	"All revisions dated after 12/17/08 to approved plans with PCIS #08041-20000-21020  (with permit) .   New Building ""B"" at USC Campus (CNTV PHASE II).)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14733	11041-20000-17778	315 W AVENUE 38	90065	1	145-5A223 330	5451013023	R3-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	Apartment			08/22/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.09117	-118.21236	Plan check roof mounted 46.8KW Photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14734	12041-10001-14539	15100 W VENTURA BLVD	91403	4	168B145  1071	2276006021	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			Reviewed by Supervisor	01/03/2013 12:00:00 AM	ADDRESS	34.15292	-118.46192	Plan review is for changes to permitted set of plans. Changes are outlined in Bulletin 1, 2 and 3 issued by the architect and attached to the revised sheets.PLAN CHECK ONLYChange of use from restaurant to CHASE bank.  Per applicant request, plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14735	14041-20000-03775	23509 W BALTAR ST PV1	91304	12	189B093   174	2020017038	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.21622	-118.63904	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 225A MAIN SERVICE PANEL. 9.5 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS, WITH (38) CANADIAN SOLAR #CS6P-250PX, (38) OP300-MV, (2) 5000A-US-ZB-U SOLAREDGE INVERTERS, (1) 125A LOAD CENTER.LOW PERMIT FEES DUE TO 2012 SENATE BILL NO 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14736	11041-10000-14003	175 S HOBART BLVD	90004	4	138B193  1273	5517012020	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10, 2114.20	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2011 12:00:00 AM	07/29/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.07166	-118.30563	ROOF-MOUNTED PV SYSTEM FOR SFD-14.9KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14737	18041-20000-16507	8432 W 3RD ST	90048	5	138B173   810	5511032040	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.073	-118.3743	Plan check for Title 24 only in existing space, T.I. restaurant. Total area: 1405 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14738	18041-10000-09000	5914 W SATURN ST	90035	10	129B173   740	5068018003	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			03/12/2018 12:00:00 AM			Reviewed by Supervisor	05/31/2018 12:00:00 AM	ADDRESS	34.04983	-118.36865	Plan check for power and energy for 45 units appartment 4 story residential  building. Total area: 34,518 sq ft.Note: Fire Alarm has NOT been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14739	12041-20000-27631	17071 W VENTURA BLVD #104	91316	5	168B133    26	2258013014	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.16043	-118.50532	Plan check for energy only. 1322 sqft. two story commercial building. SUPPLEMENTAL PERMIT TO CHANGE ADDRESS FROM 17061 W VENTURA BLVD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14740	18041-10000-01232	850 S BROADWAY	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.04248	-118.25568	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14741	12041-20000-04695	16060 W VENTURA BLVD #113 &-112.5	91436	5	168B141   600	2283011023	C2-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM			Corrections Issued	03/01/2012 12:00:00 AM	ADDRESS	34.1561	-118.48335	T-24 lighting plan check for new restaurant.  CONVERT TAKE OUT RESTAURANT TO RESTAURANT & CHANGE OF USE OF ADJACENT SPACE FROM RETAIL TO RESTAURANT(21' X 42'); INTERIOR REMODEL ONLY; GREASE INTERCEPTOR MOVED TO PARKING LOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14742	12041-20000-13980	121 N AVENUE 60	90042	1	153A229   415	5492014001	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.20	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.1118	-118.19015	fire alarm system church	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14743	19041-10000-12323	1513 W SEPULVEDA BLVD	90501	15	045B193   519	7347017071	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	06/15/2020 12:00:00 AM		Issued	06/15/2020 12:00:00 AM	ADDRESS	33.81532	-118.30375	******SEE COMMENT*******PC FOR CHANGE OF USE FROM BANK AND RETAIL SALES TO AGRICULTURE FACILITY. SCOPE INCLUDES NEW SERVICE RATED 3000A 120/208 3PHNEW CIRCUITS, PANELS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA  17692 SQ.FT  B#19016-10000-09689	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14744	16041-10003-29411	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	33.97808	-118.40726	"REVISIONS # 8 TO PERMITTED PLANS: RESTROOMS ON EACH LEVEL HAS LIGHTING CHANGES DUE TO ROOM RECONFIGUERATION; GENERATORS ( 2 EA 1500KW) REPLACED WITH ONE (2500KW)   GENERATOR;INSTALL EMPTY 5"" CONDUIT ON 4160V SIDE  FOR FUTURE SWBD INSTALLATION;REMOVE COLUMN UPLIGHTS; TITLE 24 FORMS REVISED))))))))))Full PC for core and shell alteration. Change of use from airplance hangar to office, 4-level building. Methane zone. All equipment on single line is new, shaded areas on single line to be done under a different scope. Installing (2) new main services medium voltage switchgears. MVSG1 is 3phase 3Wire 2000 Amps. MVG2 is 3phase, 3Wire 2000Amps. New lighting. Total sqft = 375,622 (Applicant assumption). ** Note Title 24 form have not yet been provided."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14745	10041-10001-19241	6223 W FRANKLIN AVE	90068	4	150A189   170	5586006028	C1-1D	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM			PC Approved	10/07/2010 12:00:00 AM	PIN	34.10543625	-118.32483465	Revision to the approved plan. Change the type of lights. EPC is for T24. (((((((((((((Ti in an existing retail space. Plan check for T24 and energy.))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14746	19041-20000-36018	2545 S AIKEN AVE	90064	5	126B161   140	4318012009	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.04139	-118.41731	PV1. INSTALL 6.00 KW DC GRID-TIED PHOTOVOLTAIC SYSTEM WITH (15) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14747	12041-20000-24935	626 W WILSHIRE BLVD # 900	90017	9	129A209    83	5144006025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	34.04843	-118.25695	Install receptacle circuits and remodel suite 900.  Plan  check for energy and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14748	15041-20001-04974	1660 N ROSCOMARE ROAD	90077	5	147B145    80	4377016016	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	ADDRESS	34.10034	-118.46273	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.8KW INTERCONNECTED WITH MSP.(45) LG MONOX 300WATTS MODULES(45) ENPHASE M250 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14749	14041-20000-22874	5529 N SUNNYSLOPE AVE	91401	4	174B157   723	2344008015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.17113	-118.42701	Standard Plan: 5.5KW PV1 roof-mounted system including: (17) SunPower E20-327 modules and one PowerOne PVI-6000-OUTD inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14750	18041-10000-24995	10635 W SANTA MONICA BLVD	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.05353	-118.43031	TI IN AN EXISTING OFFICE AREA ON THE 2ND FLOOR OF A 3 STORY BULDING.T-24 ENERGY ONLY. BULDING PERMIT# 18016-10000-20002	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14751	12041-20000-08091	145 S FAIRFAX AVE STE 201B-2nd floor	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	PIN	34.07292853	-118.36175524	TI for an office. 1208 conditioned sqft, 2nd story. 4 story commercial building. Plan check for energy and emergency lighting. Suite 201B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14752	13041-10001-31151	735 S FIGUEROA ST # 211	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Expired	04/27/2016 12:00:00 AM	ADDRESS	34.04878	-118.26079	First time tenant -victoria sectret- in commercial space, POWER AND ENERGYfIRE ALARM VARIANCE IS SUBMITTED TO SEPERATE PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14753	18041-20000-04018	926 N NORDICA DR	90065	1	153A221   316	5475017025	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.11284	-118.22039	PV1.  Install 3.9 kW PV system.  (12) modules with 3.8 kW rated string inverter.  27 kWh energy storage system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14754	17041-10000-42462	1900 S AVENUE OF THE STARS #150	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR AN EXISTING COMMERCIAL OFFICE SPACE FOR SUITE 150. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3204 SQ. FT. B#17016-10000-32315	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14755	16041-20001-30702	1616 N POINSETTIA PL	90046	4	147B181   326	5548009035	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.10037	-118.34774	6/6/17changes to an approved set of plans.  changes include line side tap.  this is plan check only.(((((Plan check for roof-mounted solar array on an apartment building. 92kW ungrounded system (36+28+28). (327) 340W pv modules.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14756	13041-10000-10031	5240 N LANKERSHIM BLVD #200	91601	4	171B173  1387	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.16613	-118.3751	RENOVATION OF EXISTING OFFICES. PC FOR ENERGY ONLY. T24. TOTAL AREA 2235 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14757	13041-10000-03591	6212 N ELMER AVE	91606	2	177B173   352	2336025009	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	34.18356	-118.37673	PV1 2.45kw MICRO INVERTER SINGLE STORY HOUSE. [MIRCRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14758	19041-10000-05146	515 S FLOWER ST # 3000	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLAN CHECK FOR TITLE 24 ONLY FOR -= PROPOSED TENANT IMPROVEMENT TO OFFICE SPACE (APPROX. 7151 SQFT). NON-BEARING PARTITION WALLS. ALL POWER SUPPLIES/DRIVERS SHALL BE CLASS 2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14759	18041-20000-22591	1130-1132 N BEACHWOOD DR 1-15	90038	13	144B189   497	5534014017	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			06/18/2018 12:00:00 AM			Re-Activate Permit	05/05/2020 12:00:00 AM	ADDRESS	34.09169	-118.32105	New 4-story 15-unit apartment building.  600A 240/120V 3ph-4w service.  Plan check for power and energy.  Building permit filed under 18010-20000-00929.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14760	19041-10000-07473	1100 S HOPE ST STE 101	90015	14	127-5A207 333	5139005***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.04195	-118.2631	New medical office (923 SF) on the first floor of a HiRise Building in Suite #101. Plan Check for Power & Energy. Building Permit: 19016-40000-05784	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14761	15041-10000-28707	3401 W 3RD ST	90004	13	135B197    41	5501013042	C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	PIN	34.06970871	-118.28991532	ENERGY PLAN CHECK FOR REPLACING (6) (E) SUB-STANDARD LIGHT POLES & SUB-STANDARD FIXTURES W/ NEW CONCRETE LIGHT PEDESTALS, POLES & LED FIXTURES. PERMIT FEE IS PAID UNDER PERMIT # 15041-10000-21054	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14762	19041-20001-08771	3441 N CAHUENGA BLVD	90068	4	159B177   374	2425025008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.13207	-118.35326	NEW 10.8KW AC ROOFTOP PV SYSTEM ON (E) SFD. SCOPE OF WORK INCLUDES 30 360W SUNPOWER MODULES WITH INTEGRATED MICROINVERTERS, (1) 200A SERVICE SUB PANEL, AND (1) 125A PV DISTRIBUTION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14763	14041-20001-32082	12334 N KENNY DR	91344	12	219B137   129	2609020017	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM			PC Approved	12/17/2014 12:00:00 AM	ADDRESS	34.29423	-118.49852	PV1 INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN ELECTRIC PANEL. 16.32 KW DC/12 KW AC. SYSTEM USES POWER OPTIMIZERS.EXPEDITE FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14764	13041-10000-11568	12445 N GLADSTONE AVE	91342	7	219B161   245	2525018058	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.2961	-118.41248	Lighting TI for an office/support building for an industrial manufacturing site.  2 stories, 6290 sq ft.  Title 24 plan check only.  Permit already pulled under application #12041-20000-16720	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14765	14041-20000-27118	15027 W FLORENTINE ST	91342	7	219B145   534	2611029031	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.2944	-118.45916	PV1Install-roof mounted solar array on SFD. System size: 3.87kW.(18) EnPhase M215-IG microinverters(18) SolarWorld Poly SW 250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14766	15041-10000-14774	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008023	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Closed	06/01/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	500 kW temporary generator for fire pump #6 operation during construction before release of power to site.  Permit for 1 MW temporary generator for power to (2) fire pumps previously issued under 15041-10000-05773	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14767	13041-10001-28785	19557 W GILMORE ST	91335	3	180B117   774	2132013017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.18763	-118.55994	][][]EXPEDITED PER APPLICANT REQUEST ][][][]PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A SINGLE STORY HOME. INTERCONNECTING WITH (E) 100A MAIN SERVICE. SYSTEM IS XFORMERLESS, WITH (20) MODULES: TRINA SOLAR #TSM-250PA05.18(1) SOLAREDGE #SE3800A-US(20) SOLAREDGE OPTIMIZERS: POWERBOX, 250W, #OP250-LV-MC4SM-2NA-Z	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14768	15041-10002-23907	2651 S HOBART BLVD	90018	8	123B193   848	5053011024	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Apartment			11/04/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.0311	-118.30806	11/04/2016 Changes to an approved set of plans. Changes include increase elevator size from 30 HP to 40HP and additonal of Elevator machine room and whell chir lift. Changes has been clouded as delta 4 only{{{{{{NEW 2 STORY APARTMENT BUILDING 800 AMPS SERVICE.  PLAN CHECK FOR POWER AND ENERGY. FIRE VARIANCE NOT RQUIRED.}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14769	19041-10000-23192	5670 W WILSHIRE BLVD 13TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI IN COMMON AREAS & CORRIDORS OF THE 13TH FLOOR. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.  1,072 SQR FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14770	12041-10000-18770	17015 W DEVONSHIRE ST	91325	12	204B133   170	2695020033	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Approved	08/09/2012 12:00:00 AM	ADDRESS	34.25768	-118.50301	Plan check for T24 Energy facade outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14771	17041-20000-42326	626 S LANDFAIR AVE	90024	5	135B149   325	4363006007	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			11/22/2017 12:00:00 AM			Verifications in Progress	08/21/2018 12:00:00 AM	ADDRESS	34.06671	-118.44879	PLANCHECK FOR POWER AND ENERGY. NEW CONSTRUCTION 3 STORY W/10 UNIT APARTMENT.BUILDING PLANCHECK TO BE SUBMITTED.GPI PLANCHECK # 17030-10000-07999	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14772	14041-10000-16549	450 S WESTERN AVE	90020	10	135B193   649	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	plan check for power and energy. not methane. plans are appproved under 14041-10001-16549, permit under master application. BLDG#14016-10-04268:TENANT IMPROVEMENT, MARKET INCLUDING MEAT AND SEAFOOD DEPARTMENT AND KITCHEN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14773	16041-10000-04556	9018 N NOBLE AVE	91343	6	195B145    81	2651019009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.23425	-118.46092	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.137KWDC. 31 MODULES AND 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14774	19041-10000-15391	4501 S WADSWORTH AVE	90011	9	112-5A209 151	5108027003	PF-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2286.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.00268	-118.2593	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14775	17041-10000-14768	3334 W SAN FERNANDO ROAD BLD E	90065	13	153B209   129	5458003021	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Issued	07/21/2017 12:00:00 AM	ADDRESS	34.11791	-118.24936	PC for title 24 energy only for a new 20' X 60' WALK-IN REFRIGERATION SYSTEM IN EXISTING WAREHOUSE SPACE. Installing new equipment, circuits and lights.Total connected load less than 400ampTotal affected area 1600sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14776	15041-10001-29132	100 WORLD WAY SPACE 160	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	(11/2/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE REVISIONS TO T-24 LIGHTING AND CALCS.  THIS IS PLAN CHECK ONLY.  PC FOR ENERGY. T.I. TERMINAL 1 OF LAX. EXISTING RETAIL STORE. TOTAL AREA 745 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14777	19041-10000-05196	1530 W SUNSET BLVD	90026	1	139-5A209 241	5404020002	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1975.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Issued	02/14/2019 12:00:00 AM	ADDRESS	34.07614	-118.25635	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL WITH 29 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14778	11041-10000-22616	1566 W COLORADO BLVD	90041	14	162A227   108	5689018021	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.13932	-118.20035	Electrical and T 24 Energy for remodeled Trader Joe's.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14779	18041-10000-31874	550 S HOPE ST 22ND FLR	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT WORK ON APPX 4918 SF. T-24 ENERGY ONLY IN SUITE # 2250. BLDG PERMIT: 18016-10000-19509	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14780	18041-10000-09270	3836 N HAYVENHURST DR	91436	5	162B141   231	2286021041	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	05/30/2020 12:00:00 AM	ADDRESS	34.14043	-118.48528	$0.00 fee due to senate bill 1222, LB1414PC for 40kW(ac) PV ground mounted system for SFD. Installing 140 modules [44.8kW(DC)], 140 optimizers, 225 load center and four 10kW central inverters connecting system to line side of main panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14781	16041-10000-45161	4030 S WESTERN AVE	90062	8	114B193   331	5021008030	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Closed	09/18/2018 12:00:00 AM	ADDRESS	34.01061	-118.30872	PC FOR POWER. 600 A SERVICE-PANEL REPLACEMENT IN A COMMERCIAL BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14782	13041-10000-36247	11184 N LAUREL CANYON BLVD	91340	7	210B149   454	2613023055	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.27353	-118.44757	PV1, Install 3.75 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (15) Modules: Trina Solar TSM-250PA05.18.(15) Optimizers: Solaredge OP250-LVMC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14783	19041-20000-13876	3024 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Issued	04/18/2019 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14784	19041-10000-01458	708-712 S NEW DEPOT ST	90012	1	135A213    92	5407007001	R4-1	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Apartment			02/07/2019 12:00:00 AM			PC Info Complete	03/11/2019 12:00:00 AM	ADDRESS	34.06499	-118.24224	METHANE GAS DETECTION SYSTEM FOR NEW 6 STORY 33 UNIT APARTMENT BUILDING. Installation of nine sensors and four strobes. BLD# 18010-10000-00498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14785	18041-20000-32872	19916 W TURNBERRY DR	91356	3	162B113    68	2180020006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.14091	-118.56751	pv1install roof mounted pv system sized 12.8KW AC interconnected with msp.(42) 325 watt modules(2) inverters salivia	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14786	19041-10000-51972	1623 W SEPULVEDA BLVD	90501	15	045B193   479	7347017060	M2-1VL, [Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	33.8167	-118.30751	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14787	18041-10000-18488	333 S ALAMEDA ST	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.04448	-118.23824	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14788	11041-10001-24890	500 W WORLD WAY Terminal 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM			PC Approved	03/19/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Modification to a previously approved set of plans.  Modification to relocated Panel 1HPB7 and connected sub-panels and transformers from interior electrical room to exterior of building.  PLAN CHECK ONLY.<<<<Plan check power only for concession stand upgrade for LAX Terminal 5. Concession stands future.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14789	17041-10000-39164	10017 S CENTRAL AVE	90002	8	090B209   258	6049028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM			PC Approved	10/30/2017 12:00:00 AM	ADDRESS	33.94513	-118.25433	EXISTING AUTOZONE TO EXPAND INTO ADJACENT BAY REFIXYURE SHELVING. RELOCATE POWER & LIGHTS -PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT. B# 17016-10000-32190	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14790	11041-10000-25842	10250 W CONSTELLATION BLVD Floor 1-Floor 35	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM			Corrections Issued	02/08/2012 12:00:00 AM	ADDRESS	34.05735	-118.41746	Changing all lighting in stairwells of a 35 story commercial/office building.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14791	19041-20001-52780	693 E MILFORD ST	90042	14	150A233    22	5312023036	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Hermon	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.10673	-118.17944	Revision to approved plans.  Relocation of equipment and additional disconnects.  $0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.(((Plan check for PV roof mounted system, PV system size: 7.56KW with 24 PV Modules and 1 inverter(7.6KW) and Energy Storage System size: 40.5KWh, with 3 Energy Storage Device(13.5KWh))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14792	13041-20000-06287	360 S MAPLETON DR	90024	5	138B157    25	4359013024	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2013 12:00:00 AM			Plans on Hold	03/12/2013 12:00:00 AM	ADDRESS	34.07629	-118.43071	New addtion/remodel of a single family residence.  New 600 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14793	17041-10001-25063	10250 W SANTA MONICA BLVD # 1240	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Changes to approved set noted as Delta-3: Remove Panel ""H"" (480/277V), and add fused disconnect on the primary side of transformer. <<Full Plan check- Johnston & Murphy - in retail space# 1240. Electrical service is existing from ""MSA"", attached is approved based build. plan as reference.>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14794	17041-10000-30260	560 S LOS ANGELES ST	90013	14	127-5A211  83	5148017009	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.04462	-118.2487	T-24, PC FOR ENERGY ONLY. REPLACING OUTDOOR LUMINAIRES WITH LED TYPE. TOTAL AFFECTED AREA IS 53125 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14795	16041-10000-45066	10250 W SANTA MONICA BLVD UNIT 2830	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	TI TO RETAIL SPACE 'COTTON ON'. PC FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14796	16041-10003-04795	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	12/16/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	Revision to approved set of plan for a Museum/Restaurant/Retail/Office building. All changes are clouded and noted as Delta-36.  Add loads 9circuits) to existing panelboard; Revise lighting plan, replace luminiares, updated T24 calculation. <<PC FOR POWER AND ENERGY.  ADD THEATER STRUCTURE TO (E) MUSEUM/RESTAURANT/RETAIL/OFFICE BLDG. 2 NEW SERVICE WITH 3000A, 5000A , ADDITION OF NEW PANELS AND DEVICES. B# 13014-10000-03762>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14797	12041-10000-17226	11776 W IDAHO AVE	90025	11	126B149  1247	4262013001	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			07/27/2012 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.04143	-118.45674	PLAN CHECK POWER AND ENERGY FOR NEW 4 STORY 9 UNIT APARTMENT OVER BASEMENT GARAGE. 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14798	11041-10000-15644	515 S FIGUEROA ST # 1980	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM			PC Approved	07/26/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	REMODEL OF OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14799	18041-20000-29977	935 N VIGNES ST	90012	14	132A217    37	5409016008	[Q]M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.05767	-118.23205	PV2.  Install 7.8 kW DC roof mounted grid tied PV system.  (26) modules with 9 kW rated string inverter installed on 200A 240/120V 3ph-4w service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14800	19041-10000-02079	5101 W OBAMA BLVD	90016	10	120B177  1084	5047004032	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.0217	-118.35615	PC FOR ENERGY ONLY. INTERIOR REMODEL AT PHARMACY. SCOPE OF WORK INCLUDES RELOCATED LIGHTING ONLY. TOTAL SQ. FT. 1015	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14801	13041-20000-01811	7061 N KESTER AVE I-PV-1	91405	6	183B149   169	2220006***	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Expired	04/09/2015 12:00:00 AM	ADDRESS	34.19912	-118.45763	SOLAR SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14802	12041-10000-04220	4015 W BRUNSWICK AVE	90039	13	157-5A207 117	5594027028	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM			Not Ready to Issue	03/27/2012 12:00:00 AM	ADDRESS	34.12556	-118.26593	(8) SOLAR PANELS ON SFD ROOF. Solar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.(*NOTE* Express permit was previously issued under PCIS 11041-10000-27078; supplement fees for 7 INV & 1 panel required)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14803	16041-20001-15707	14334 W RUNNYMEDE ST	91405	2	186B149   503	2215024007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.20562	-118.44572	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (49) modules, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14804	19041-10000-44811	23333 S CLEARPOOL PL	90710	15	042B193   209	7438008018	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	33.81289	-118.30042	[EPLAN] PLAN CHECK FOR 5.0KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 22 MODULES USING P400 OPTIMIZERS CONNECTED TO NEW 200A SERVICE  NEW SERVICE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14805	16041-20001-34027	11140 N JELLICO AVE	91344	5			R1-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.27352	-118.51791	expedite per applicantpv1install roof mounted pv system sized 9.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14806	11041-20000-24511	10940 W WILSHIRE BLVD	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM			PC Approved	11/16/2011 12:00:00 AM	ADDRESS	34.05822	-118.4452	T.I.  Existing office space.  Remodel of 10th floor office suit.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14807	16041-20000-04729	2102 W COLORADO BLVD	90041	14	162A223   120	5686003018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.13897	-118.21215	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,704 sq. ft. Note: Building application has been generated under 16016-20000-02962	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14808	19041-20000-50471	13263 N WHEELER AVE UNIT 29	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS (ENPHASE IQ7PLUS)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14809	13041-10000-00657	9804 N SUNLAND BLVD PV1	91040	7	201B181   200	2545017009	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM			Corrections Issued	09/24/2013 12:00:00 AM	ADDRESS	34.24742	-118.34992	Additional roof-mount system is/has been installed via express permit and is described below. Ground mounted PV system. PLEASE CHECK INVERTER FOR UL LISTING. Ashe Residence. 3.57kW. Plans were submitted in Van Nuys.13041-10000-00226:   3.06KW ROOF MOUNTED SOLAR PV ELECTRIC SYSTEM INSTALLATION. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14810	16041-20001-40733	14043 W AUBREY ROAD	90210	4	159B153    17	2272033060	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.13567	-118.44026	EXPEDITED PER APPLICANTS REQUEST.Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14811	16041-10000-42354	212 W 7TH ST	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.04468	-118.25286	T-24, PC FOR ENERGY ONLY. CHANGE USE OF (E) RETAIL SPACE AT GROUND FLOOR LEVEL TO A RESTURANT WITH LESS THAN 49 OCCUPANTS. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLE.S. TOTAL AFFECTED AREA IS 410 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14812	12041-10000-21346	12035 W OSBORNE ST #  5	91331	7	210B165   543	2532017066	(Q)C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Pacoima		1041.08	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM			Not Ready to Issue	11/29/2012 12:00:00 AM	ADDRESS	34.27301	-118.39494	because of fees issued 5 separate express permits as indiatecd on the plansNew fire alarm system for an appartment BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14813	19041-20000-50290	9837 N SAN FERNANDO ROAD	91331	7	201B165    93	2624019004	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	08/13/2020 12:00:00 AM		Permit Finaled	09/14/2022 12:00:00 AM	ADDRESS	34.24885	-118.40425	Plan check for power and energy, 1600A Service, new lighting and receptacle. Total area: 21,666 sq ft. B#19010-20000-05333*************************************************Building Builidng work description: (N) MASONRY BUILDING WAREHOUSE************************************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14814	14041-10000-17378	12534 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	33.97822	-118.412	PC FOR METHANE MITIGATION. NEW Type VA  6-unit  4-story  APARTMENT BUILDING with attached parking. 1 PANEL, 27 DEVICES.BUILDING APP# 14010-10000-01298	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14815	12041-20000-09809	650 N FIRTH AVE	90049	11	138B141   377	4429017001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.07252	-118.47496	New Single family Dwelling 72' x 141' irregular shape with subterranean garage.  COMPLY WITH DEPARTMENT ORDER effective date 10/29/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14816	13041-20000-23928	491 N TIGERTAIL ROAD	90049	11	135B141   184	4403024002	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.0684	-118.47886	NEW CONSTRUCTION. SINGLE FAMILY DWELLING. PC FOR POWER. NEW 800A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14817	16041-10000-05402	22222 W VICTORY BLVD BLDG D	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUDRY ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14818	15041-10000-08253	3800 W MT LEE DR	90068	4	159B189     8	5581010900	OS-1XL	Central	Hollywood	Hollywood United	YES	9800.09	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Issued	10/28/2015 12:00:00 AM	ADDRESS	34.13546	-118.3184	installation of  redundant stanby generator to support Mt  Lee radio equipment operations during loss of normal power.PLAN CHK IS FOR THE GENERATOR INSTALLATION AND ENERGY COMPLIANCE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14819	11041-20000-09677	3992 S INGLEWOOD BLVD	90066	11	111B157  1480	4214021001	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Apartment			05/12/2011 12:00:00 AM	08/10/2011 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.00232	-118.42561	PLAN CHECK POWER AND ENERGY FOR TWO STORY 21 UNIT APARTMENT BUILDING OVER ONE STORY PARKING GARAGE. MODIFICATION TO SEPERATE FIRE ALARM HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14820	10041-10005-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	02/04/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	single line diagrams with existing switchboards and distribution boards supplying tenant panel boards at the North Core  Concessions. Review was requested such that approved plans will be on site as tenants are now moving into and modifyiny their tenant spaces. These plans show the tenant design loads and any modification from the design loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14821	15041-20001-01523	13564 N HERRICK AVE	91342	7	228B145   428	2501014010	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2015 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.3183	-118.46978	plan check for nonstandard plan. Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14822	17041-10001-02341	523 W 147TH ST	90248	15	075B201   172	6119009047	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2017 12:00:00 AM			PC Approved	02/01/2017 12:00:00 AM	ADDRESS	33.89895	-118.28392	CHANGES TO APPROVED SET. REDUCE BY 1 MODULE AND INVERTER IS NOW A 3.8KW AC. THIS IS PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14823	17041-10000-39192	5161 N LANKERSHIM BLVD #B101	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.16452	-118.37469	PC FOR T.I. TO EXISTING OFFICE SPACE IN BASEMENT OF EXISTING 4-STORY BUILDING FOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW LIGHTS RECEPTACLES AND CIRCUITS. TOTAL AFFECTED AREA  1,180 S.FB# 17016-10000-32202	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14824	15041-20001-21741	6250 N TOPANGA CANYON BLVD F-1555	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Changes to approved set.  Revised circuit home runs and specified equipment used.*****Previous Work Description*****Plan check for power and energy. Project scope is a first time tenant at the Westfield Village. Total lighting area = 900 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14825	13041-10000-24016	10201 W PICO BLVD BLDG 103	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM			PC Approved	09/06/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	Office TI on ground floor of Fox Studio campus office building #103.  Emergency lighting provided within the architecturally defined path of egress.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14826	18041-10000-08605	7133 N ETIWANDA AVE	91335	3	183B125   284	2125003004	[Q]CR-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.2003	-118.53182	REMOVE OUTDOOR HID FIXTURE AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14827	19041-20000-13052	15830 N HART PL	91406	6	183B141  1010	2224029012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	PIN	34.19726862	-118.47808935	Plan check for PV roof mounted system, system size: 11.7KW DC, 10.2KW AC CEC with 42 PV modules and 42 Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14828	14041-10001-06741	6565 W HOMEWOOD AVE	90028	4	147A187   330	5547027019	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.09533	-118.33264	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14829	16041-10000-01613	5326 W WESTHAVEN ST	90016	10	123B177  1385	5043010007	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.03073	-118.36013	NSTALL 5.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MODULES: SILEVO TRIEX U290 BLACK(1) INVERTER: ABB PVI-4.2-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14830	19041-20001-24156	120 N BENTLEY AVE pv1	90049	5	138B149   115	4366002017	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	34.07529	-118.45813	07/11/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to reflect field installation.*****Original Work Description*****permit fee $0.00 by state senate bill no. 1222pv1install roof mounted pv systen sized 15.2KW AC interconnecte dwith msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14831	18041-10000-23333	9825 N MASON AVE	91311	12	201B109   143	2748005021	(T)(Q)CM-1L, (T)(Q)CM-1LD, (T)(Q)M1-1, (T)(Q)M1-1D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.24844	-118.58019	REMODEL TO AN EXISTING COMMERCIAL BUILDING (GYM), NEW PANELS AND CIRCUITS. NEW ADDED LOAD >400AMP. FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14832	18041-20000-48123	8235 N OWENSMOUTH AVE 1-38	91304	3	192B105   642	2110001085	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	34.21866	-118.60175	plan check for power per applicant.  replacing existing meter sections and corresponding feeders.  this is plan check only.   permit fees paid under application number 10841-20000-22056.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14833	16041-10000-29889	18848 W ERWIN ST	91335	3	177B121   254	2127014003	RA-1-K-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.18374	-118.54419	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 22632 SQ FT.(outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14834	18041-20000-22771	565 N TIGERTAIL ROAD	90049	11	138B141   567	4494013009	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			PC Info Complete	09/19/2018 12:00:00 AM	ADDRESS	34.07048	-118.47921	Plan check for new Single Family Dwelling 2 story building. 800A Service. Permit pulled under Building application number. Plan check only. B#15010-10000-04687	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14835	11041-10000-16876	2941 W 70TH ST	90043	8	102B189   584	4008011058	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01, 2352.02	Electrical	Electrical	Public Safety Only			08/10/2011 12:00:00 AM	08/10/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.97648	-118.3254	Delta 2 Revisions Only (add relays fpr HVAC shutdown)(Permit previously issued under PCIS 11041-10000-10860 for a new fire alarm system)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14836	19041-10000-52070	5813 N VESPER AVE	91411	4	174B149   234	2244004003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.17618	-118.4512	NEW PV1 INSTALLATION 5.76KWdc(5.00KWac) USING 16 POWERXT-360R-PD MODULES, 16 SE P370 POWER OPTIMIZERS & 1 SE5000H-US CENTRAL INVERTER. CONNECTED TO A 200 AMP EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14837	13041-20000-04124	616 S KENMORE AVE	90005	10	135B197  1102	5502028006	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			02/19/2013 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.06289	-118.29646	Full plan check for new 57 unit apartment. Fire alarm variance has been filed. METHANE Zone.extention granted to 8/19/15	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14838	12041-10000-25850	900-930 W WILSHIRE BLVD	90017	9	130-5A209 197	5144008020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Closed	01/07/2014 12:00:00 AM	ADDRESS	34.05001	-118.25963	TEMPORARY POWER #1 FOR CONSTRUCTION OF A HIGHRISE BLDG. 800A DELTA SYSTEM. TEMP  POWER #2 AND TEMP POWER #3 DEFERRED SUBMITTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14839	10041-10000-06192	550 N FIGUEROA ST	90012	1	133-5A213  51	5407003036	C2-2D	Central	Central City	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/15/2010 12:00:00 AM	ADDRESS	34.06175	-118.24658	AT THE ORSINI APARTMENT BUILDING, REMODEL THE LOUNGE AREA .PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCTY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14840	15041-20000-20078	10407 N JELLICO AVE	91344	12	204B129    27	2733012055	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.25969	-118.51894	Addition of inverter and modules to existing solar PV array.  Total system size = 6.8 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14841	14041-20000-03174	3414 N THE PASEO	90065	1	153A217   436	5460009007	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Expired	04/07/2016 12:00:00 AM	ADDRESS	34.11169	-118.23281	PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14842	19041-20001-45964	16257 W LONDELIUS ST	91343	12	195B137   716	2688013010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.22941	-118.48701	Revisions to approved set to match field installation. (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14843	19041-10000-29762	3651 S VERMONT AVE	90007	8	120B197  1054	5040030037	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/01/2020 12:00:00 AM	ADDRESS	34.02182	-118.2918	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14844	18041-10000-13333	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Issued	04/12/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	PLANCHECK FOR T24 ENREGY. SIGNLIGHTING CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14845	16041-20000-23971	15425 W VICTORY BLVD	91406	6	180B145   753	2234014019	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Expired	08/15/2018 12:00:00 AM	ADDRESS	34.18685	-118.46993	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (38) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14846	15041-20000-15149	5150 N BELLAIRE AVE	91607	2	171B161   601	2357003017	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2015 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Expired	06/12/2017 12:00:00 AM	ADDRESS	34.16441	-118.40927	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING 31 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14847	19041-10000-20509	4814 W 1ST ST	90004	4	138B189  1002	5516008011	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.07291	-118.31619	[E-PLAN] Install 2 x Tesla Powerwall Energy Storage System  @ 27KWH & 2 New 200A Load Center on (E) SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14848	10041-10000-13852	1135 N MISSION ROAD	90031	14	133-5A223  21	5210007030	M2-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	09/15/2010 12:00:00 AM	PIN	34.06160547	-118.21349966	TENANT IMPROVEMENTS; INTERIOR WORK ONLY PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14849	19041-20001-16302	10860 N SWEETWATER CT pv1	91311	12	210B117   337	2708027***	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	34.26825	-118.56469	07/11/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to reflect field installation.*****Original Work Description*****pv1install roof mounted pv system sized  5.4KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14850	14041-20001-24840	7006 S HOOVER ST UNIT 3	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #3.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14851	19041-20000-40460	2713 S CLUB DR	90064	5	126B161    76	4308003004	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.04234	-118.40624	PV1.  Install 14.06 kW DC/11.4 kw AC roof mounted grid tied PV system.  (38) modules with a 11.4 kW rated inverter.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14852	13041-20000-21486	3200 W 48TH ST	90043	8	111B185   357	5013026016	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	33.99988	-118.32886	NEW SERVICE AND ELECTRICAL SYSTEM. ALL CIRCUITS NEW. RENOVATION OF FIRE DAMAGE CHURCH. PLACE OF ASSEMBLY. NON HAZARDOUS. PC FOR POWER AND ENERGY. TOTAL AREA 9961 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14853	15041-20001-42882	12954 W MAGNOLIA BLVD	91423	4	171B161   579	2358031016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/22/2016 12:00:00 AM	ADDRESS	34.16472	-118.41547	Expedited RSES plan check fee per applicant request.  PV1.  Install 20.8 kW DC roof-mounted utility-interactive PV system.  (64) SunEdison SE-F325BzC-4y modules w/ (2) SolarEdge SE7600A-US and (1) SolarEdge SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14854	12041-10000-19162	725-727 W PACIFIC COAST HWY	90744	15	036B205  1126	7414032032	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM			PC Approved	08/29/2012 12:00:00 AM	ADDRESS	33.79093	-118.27162	PLAN CHECK FOR T24 ENERGY/EMERGENCY OFFICE TI. (STATE FARM)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14855	18041-10000-39637	13550 W HERRON ST	91342	7	225B157   462	2510019017	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.3136	-118.42795	REMOVE IND/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14856	16041-10000-23006	2912 S ALSACE AVE	90016	10	120B177   394	5049024054	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Expired	08/13/2018 12:00:00 AM	ADDRESS	34.02766	-118.35707	PV1, INSTALL NEW 2.12 KW DC / 3.00KW AC ROOF-MOUNTED FOR A ONE UNIT OF A 3-UNIT BUILDING.(8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14857	11041-10000-24487	1016 E LAKE ST BLDG 6-1	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/28/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.00173	-118.46049	Lincoln Place Apartment Building Project.  New 2-story apt. building with 8 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14858	15041-20000-18780	9700 N LAUREL CANYON BLVD	91331	7	201B161   612	2626005032	[Q]C1.5-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.24593	-118.41825	Plan check for PV roof mounted system. System size: 7.6kW with 32 modules and 1 inverter(7.6kW) in a multi family	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14859	16041-10000-14986	11900 N BALBOA BLVD	91344	12	216B133   483	2610002051	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.28642	-118.50125	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM MARKET TO RETAIL; INTERIOR TI OF EXISTING COMMERCIAL SPACE. SCOPE INCLUDES NEW ELECTRICAL LOADS TO EXISTING PANELS A, B, C, D, AND MAIN DISTRIBUTION BOARD, 'MDP.' NEW CONNECTED LOAD IS >400A. TOTAL AFFECTED AREA IS 33,348 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14860	15041-20000-38803	19191 S VERMONT AVE Suite 400	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	33.85656	-118.29099	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,579 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14861	17041-10000-43517	22170 W JAMES ALAN CIR #1	91311	12	207B101   214	2723013***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Apartment			12/04/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.2613	-118.61219	Plan check for PV roof mounted system. System size: 6.0kW with 18 modules and 1 inverter(6.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14862	13041-20000-15258	923 W BLOOM WALK	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.0202	-118.28926	Plan check for outdoor lighting. Plan check for ENERGY only.  Methane zone, however report shows no detectable levels of methane along with a pressure less than 2inches of water. USC. Archimedes Plaza.Edit: Permit issued under 13041-10000-17347	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14863	16041-30000-05452	2511 W 3RD ST	90057	13	135A203    96	5155033018	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.02	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.06525	-118.27685	Replace existing sprinkler monitoring system with new fire alarm system to include notification appliances in dialysis center.  Total system size = 106 modules + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14864	19041-20000-49183	6324 N ELMER AVE	91606	2	177B173    42	2336017009	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.18568	-118.37673	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 4.65 KW DC/5 KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH OPTIMIZERS AND A 5KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14865	11041-10000-19246	6701 N ETON AVE 1-298	91303	3	180B105    27	2148030035	(WC)C/I-60/1.0	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			12/06/2011 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.19217	-118.59564	NEW FIVE-STORY, TYPE-III-A, 298-UNIT APARTMENT WITH ATTACHED PKG GARAGE (Automatic fire srpinkler throughout for the story increase). See separate permit  for attached parking garage.Need to file a variance to separate the FA plans from the electrical plans.Plan check fees were determined by client.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14866	15041-10001-40374	829 E 3RD ST	90012	14	129A215   260	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM			PC Approved	04/01/2016 12:00:00 AM	ADDRESS	34.04601	-118.23547	plan check for new lighitng design. delta 4 changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14867	18041-10000-45664	14441 W ROSCOE BLVD	91402	6	192B149   361	2638022044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.22172	-118.44798	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14868	11041-10000-10180	3650 W MARTIN LUTHER KING, JR BLVD SPACE-FC8	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	T.I. TO AN EXISTING RESTAURANT IN THE BALDWIN HILLS MALL - FOOD COURT.  T-24 WITH EMERGENCY LIGHTING.  OTC PLAN CHECK ONLY.  (CHARLEY'S GRILLED SUBS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14869	18041-20000-44253	18319 W CALVERT ST	91335	3	177B125   524	2124011004	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.18187	-118.53249	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 33 MODULES (CANADIAN SOLAR 295) , 33 OPTIMIZER (SE P300) AND A CENTRAL INVERTER (SE10000H-US).  SYSTEM SIZE IS 9.9KWdc and 10KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14870	11041-10001-25150	15232 W FOOTHILL BLVD	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2012 12:00:00 AM			PC Approved	01/25/2012 12:00:00 AM	ADDRESS	34.32292	-118.46695	Plan check for Delta 1 revision to approved plans. Revise the modules in series and number of strings for 4.56KW roof mounted photovoltaic system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14871	10041-10000-19267	800 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Approved	12/13/2010 12:00:00 AM	PIN	33.94153561	-118.3984113	Replace elevator(s) and other electrical upgrade.   Plan checked at applicants request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14872	17041-10001-16227	3201 S HOOVER ST STE 1820	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.0255	-118.28448	CHANGE TO APPROVED SET OF PLANS. UPDATED T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14873	14041-10000-08594	1288 N ANGELO DR	90077	5	144B153   281	4357014006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.09339	-118.43608	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0..PV1 14.04KWdc. 240V. microinverter. STD. 1story. Roofmount. [(52) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(52)modules: {mono lg270s1c-a3}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14874	15041-20000-25764	21600 W OXNARD ST Suite 250	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,796 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14875	16041-10000-33212	2131 E CENTURY BLVD 101-208	90002	15	093A217   275	6049019***	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	33.9467	-118.23427	PC for power only for a mixed use 3-story 8-unit apartment C1 building with commercial office space and parking garage (Bldg 7 of 8). Scope includes a new 600A 120/208V 3 phase 4 wire service/distribution board. One plan is submitted for multiple apartment buildings. B#16010-10000-02992	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14876	14041-10000-34057	10700 N BAILE AVE	91311	12	207B117   228	2708012006	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.26454	-118.56234	Installation of new roof mounted solar PV array.  Total system size = 3.8 kWac.  Two types of modules used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14877	10041-10000-06749	7801 N HAYVENHURST AVE 101-102	91406	6	189B137   125	2205009094	M2-1	North Valley, South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM	04/19/2010 12:00:00 AM		Permit Finaled	04/26/2010 12:00:00 AM	ADDRESS	34.21242	-118.49404	title 24 for an one story bldg , office in a ware house.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14878	19041-20000-25921	10918 N CARTWRIGHT DR	91311	12	210B113   261	2708030024	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.26922	-118.5662	PV1 PLAN FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 6.3KWDC/5.76KW AC. SCOPE OF WORK INCLUDES (18) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14879	15041-10000-05766	8125 W MANCHESTER AVE UNIT A	90293	11	096B153   723	4115013030	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM			PC Info Complete	02/27/2015 12:00:00 AM	ADDRESS	33.95858	-118.43842	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS AND NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 740.  SCOPE OF WORK TO BE PERFORMED IN UNIT A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14880	16041-10000-43024	4322 W WILSHIRE BLVD suite 200	90010	4	132B189    51	5090030009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.06163	-118.32226	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 3945 SQ. FT.. B#16016-10000-28423	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14881	17041-10000-05024	633 W 5TH ST	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM			PC Info Complete	02/21/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	T.I. FOR EXISTING TAKE-OUT RESTAURANT; PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14882	14041-10000-27290	1907 E WASHINGTON BLVD	90021	14	118-5A215  14	5167019053	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	34.01997	-118.23883	PV2, INSTALL 20.4 KW DC ON CAR PORT.  MEDICAL CENTER. 6 STRINGS.(68) MODULES: CANADIAN SOLAR CS6X300P(3) INVERTERS: SOLECTRIA PVI 6600TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14883	14041-10000-00953	4632 N VISTA DEL MONTE AVE	91403	4	168A151    81	2265012012	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Apartment			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.15576	-118.44971	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14884	17041-10000-35981	8230 N TOPANGA CANYON BLVD	91304	3	192B101   625	2110001056	(Q)C1.5-1, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Issued	10/06/2017 12:00:00 AM	ADDRESS	34.21937	-118.60575	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ENERGY ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14885	17041-20000-18606	1331-1335 E 6TH ST	90021	14	126A215   289	5164008005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.03833	-118.23479	Plan check for energy only. Change of use from warehouse space to restuarant (pizzeria). New lighting (incl. emergency). New outdoor lighting under new entryway-canopy. 1,972sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14886	15041-10001-18703	1925 S CENTURY PARK EAST ste 400	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	Minimum plan check fee charged due to lost plans.  ((pc for energy.  Alteration to an exisiting office and corridore. Hi rise. Total area 779 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14887	14041-20000-00869	4260 S BRONSON AVE	90008	10	114B185   894	5024015021	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.00663	-118.33314	pv1 single family dwelling. total system size 3.4 kw ac using 16 microinverters using standard plan. using enphase m215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14888	15041-10000-33616	5742 S BANDERA ST	90058	9	108B213   659	5105024018	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	33.99003	-118.23993	T-24, pc for energy only to a commercial building. Replacing existing lighting with LED lights. Sq ft = 18110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14889	12041-10000-15156	1541 W WILDWOOD DR	90041	14	159A227   186	5479002005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.10	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.13028	-118.19978	New 3.4kw rooftop mounted photovoltaic system for an existing single family residence.  System uses AC Panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14890	19041-10000-38632	2373 N KENILWORTH AVE	90039	4	148-5A205  64	5432019015	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.10281	-118.26754	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 11.56KWdc/9.8KWac.  SCOPE OF WORK IS 34 MODULES (LG SOLAR LG340N1C-A5) WITH MICROINVERTERS (ENPHASE IQ7PLUS-72-2-US). LEADING TO A COMBINER BOX, NO PANEL UPGRADE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14891	15041-10000-02175	348 E 74TH ST	90003	9	102B205  1195	6022019002	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	33.97291	-118.26775	PV1 standard plan with 3.8kw roof-mounted system including (12) Sunpower SPR327NE modules and (1) Powerone PVI-3.8-OUTD inverter.Note. Applicant was notified for online service, but still insisted to do plan check over the counter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14892	18041-10000-43568	380-384 WORLD WAY MSC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Power plan check for a new LAX terminal, Midfield Satellite Concourse. Whole scope involves with multiple motor load per each branch ckt connected to sub-control panel and motor control panels. All load is new for the whole baggaging for the terminal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14893	15041-20001-16655	11037 N CANBY AVE	91326	12	210B125   472	2715002044	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.27077	-118.53519	Changing location of electrical equipment (MSP, AC disco, meters) from west side wall to south side wall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14894	16041-10001-09565	13368 W BEACH AVE 1-21	90292	11	108B153   847	4230007268	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			03/18/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	33.99147	-118.44362	EXPEDITE FEEPV2, rooftop solar installation on (E) 21 unit apartment. (15) LG310N1C   (1) FRONIUS SYMO 10.0-3 240* PLAN IS APPROVED BY FA DEPT. #C16-00890** RTI ISSUED UNDER BUILD. DEPT. #16016-10000-03388	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14895	10041-20001-03847	8614 W BEVERLY BLVD suite 159	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM			PC Approved	05/18/2010 12:00:00 AM	ADDRESS	34.07598	-118.37831	Delta 5 revision only on page E-13.  To install GE Series rated J fuses at the swbd, and SED circuit breakers at panels HA and HB for a series combination rating of  100,000 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14896	16041-20000-15424	444 S FLOWER ST 39th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is a portion of the 39th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 9,405 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14897	13041-10000-10721	24015 W NORDHOFF ST	91311	12	195B113    79	2781001052	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Expired	05/21/2015 12:00:00 AM	ADDRESS	34.23202	-118.57795	Application address of 24015 W Nordhoff was the result of a clerical error that the applicant has taken care of with Addressing Counter but system not updated at time of applicant submittal.  True address is 20415 W Nordhoff.  New fire alarm system for 2-story commercial bldg.  49 devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14898	14041-10000-31438	17210 W MIDWOOD DR	91344	12	216B133   429	2606017047	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.28706	-118.50866	PV1 standard plan with 8.6kw roof-mounted system including (1) 8.6 PowerOne inverter and (38) REC260 modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14899	18041-10000-46402	9075 N GLENOAKS BLVD	91352	6	195B173    87	2408032***	M1-1-CUGU, M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.23374	-118.37084	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14900	18041-10000-48589	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	33.98095	-118.40764	TI TO EXISTING OFFICE BUILDING. NEW PARKING LEVEL LOBBY, THREE LEVELS OF OFFICE SPACE. NEW 2,000AMP SERVICE, 87,000 SQR FT.BUILDING PERMIT: #14010-10000-03377. (FEE ESTIMATE ONLY. VERIFY FEES)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14901	15041-20000-22607	2409 N NOTTINGHAM AVE	90027	4	153B193   376	5588003013	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.11234	-118.30184	PV1. Install roof mounted PV system sized 6.5 kW. Interconnected with main service panel. (26) SW285 Modules(26) Enphase M250 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14902	15041-10000-34762	8271 W BEVERLY BLVD	90048	5	138B173   393	5514009052	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.07623	-118.36975	ORIGINAL PLANS LOST APPL# 15041-10000-11997 PARTIAL PERMIT FEES PAID UNDER THIS APPL NUMBER.  REPLAN CHECK FOR REPLACEMENT OF LOST PLANS. TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 3999 INDOOR/OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14903	17041-10001-11629	910 S GRAND VIEW ST	90006	1	132A201   360	5136005014	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Apartment			09/22/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.05394	-118.28101	CHANGES TO AN AN APPROVED SET OF PLAN, CHANGES INCLUDE THE REVISION OF 40 AC UNITS UNDER DELTA 3. *****PC FOR POWER AND ENERGY FOR EXISTING 4 STORY 40 UNIT APPARTMENT(TI-REMODEL). SCOPE CONSIST OF USING EXISTING SERVICE RATED AT 800A, AND REPLACING ALL UNIT PANELS WITH NEW SERVICE LOAD CALCULATIONS. ALL UNITS ON THE 4TH FLOOR(10 UNITS TOTAL) SHALL NOT HAVE AC UNITS TO ACCOMODATE FOR EXISTING SERVICE SIZE. TOTAL AREA  8145 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14904	19041-10000-42259	1532 W CAMBRIA ST	90017	1	130-5A205 111	5142023013	R4-1	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.05255	-118.271	NEW FIRE ALARM SYSTEM.  SCOPE INCLUDES (158) FA DEVICES, (1) FA PANELS, and (5) power supplies.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14905	18041-20000-45680	9322 W HAZEN DR	90210	4	153B165   296	4388019025	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM			PC Approved	03/12/2021 12:00:00 AM	ADDRESS	34.11405	-118.39689	600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new SFD.  Plan check only application for power.  Electrical permit issued under 15010-30000-01957.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14906	17041-20000-06062	837 N NORTH SPRING ST ste. 102	90012	1	135A215   307	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Issued	09/11/2017 12:00:00 AM	ADDRESS	34.06303	-118.23651	Plan check for energy only. Change of use from retail to take out restaurant. New lighting - 220sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14907	18041-20000-17559	5012 S SLAUSON AVE	90230	11	108B161   187	4217028026	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			05/11/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	33.99448	-118.40798	New fire alarm system for 4-story apartment building.  77 fire alarm devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14908	16041-20000-17104	3801 N BRILLIANT PL	90065	1	153A219   267	5462003017	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.11299	-118.22704	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP. STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14909	18041-10001-00846	761 S MAIN ST	90014	14	127-5A211 345	5144015228	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	PIN	34.0430348	-118.25325822	Plan check Title 24 only in existing space T.I. Total area: 1431 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14910	19041-20000-52812	10049 W TOLUCA LAKE AVE	91602	4	165B181   312	2424026011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.14861	-118.34937	PV1.  Install 11.34 kWDC and 10kwAC roof mounted PV system and (3) energy storage systems total of 40.5 kWh .  (36) modules with 10 kW rated inverter. Permit fees are $8.33 due to senate bill 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14911	11041-20000-15370	12121 W WILSHIRE BLVD #700	90049	11	126B145   208	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	PIN	34.04375344	-118.46845773	Plan check T24 energy/emergency for tenant improvements in Suite 700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14912	14041-10001-02368	1307 W 78TH ST	90044	8	099B197   328	6019005014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	03/05/2014 12:00:00 AM	ADDRESS	33.9695	-118.29847	][]EXPEDITED PER APPLICANT REQUEST ][][PV1, ROOF MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 100A MAIN SERVICE PANEL. SYSTEM SIZE IS 3.5 kW DC, WITH (14) TRINA  TSM-250PA15, (1) POWER-ONE INVERTER PVI-3000. SINGLE-STORY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14913	18041-20001-41263	712 E WASHINGTON BLVD	90021	9	121-5A209 142	5131006003	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.0273	-118.25708	expeditepv2install roof mounted pv system sized 10KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14914	18041-20000-21153	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check for Title 24 only. Project site is an existing 5-level parking structure. Project scope is the replacement of lighting fixtures, one for one. Existing lighting circuits to remain. Total lighting area = 530,467 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14915	12041-20000-15134	1685 W PACIFIC COAST HWY suite d	90710	15	033B193    27	7410025047	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	33.78963	-118.30714	energy plan check wing stop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14916	16041-10000-03208	5077 N LANKERSHIM BLVD 1ST FLR	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.1626	-118.37361	Full plan check for a first time tenant, restaurant, T.I. located in the first floor of a commercial building; Scope includes new lighting, receptacles,and electrical equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14917	16041-10000-08361	908 N BEL-AIR ROAD	90077	5	144B153   808	4370026013	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.08955	-118.44132	NEW 2-STORY SINGLE FAMILY  OVER ONE LEVEL BASEMENT WITH 1600MSA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14918	13041-20000-31177	19800 W DEVONSHIRE ST	91311	12	204B113   213	2726008001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.25704	-118.56565	T24 FOR 14FT POLE SIGN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14919	14041-20001-21157	20311 W HOWARD CT	91364	3	165B113   167	2174008022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	09/18/2014 12:00:00 AM	ADDRESS	34.14734	-118.57619	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 12kW(1) SolarEdge SE11400A-US transformerless inverter(40) SunPower X21-345 pv modules(40) SolarEdge P400 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14920	17041-10000-14152	1421 N LA BREA AVE	90046	4	147B181   811	5548017006	C2-1-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	PIN	34.09683211	-118.34444787	NEW CONSTRUCTION. NEW 800A SERVICE TO 2 STORY BUILDING COMMERCIAL WITH MEZ. AND PARKING GARAGE. BUILDING # 16010-10000-00203	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14921	19041-20000-32052	20812 W ACORN CIR UNIT #234	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.29428	-118.5871	Plan check for PV roof mounted PV system, System size: 3.15KW with 9 PV Modules and 9 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14922	17041-10000-03363	515 N VIA DE LA PAZ	90272	11	126B125   825	4412017031	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.03871	-118.52937	PC FOR A ROOF-MOUNTED PV SYSTEM USING 5KW INVERTER AND 17 MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14923	18041-20000-34371	5900 W WILSHIRE BLVD #400	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for Title 24 only T.I. in existing  office space high-rise building for suite #400. Total area: 9,190 sq ft. B#18016-100000-22278	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14924	16041-20000-36390	3205 W LOS FELIZ BLVD	90039	13	157-5A205 129	5594019011	R3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.12364	-118.26881	remove existing hid fixtures and replace with new led fixtures outdoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14925	13041-10000-07830	3614 S WESTERN AVE	90018	8	120B193  1364	5041015030	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.02223	-118.3087	RENOVATION OF INTERIOR LIGHTS. WORK TO BE DONE LESS THEN NEW PLAN CHECK REQUIREMENTS. PC FOR T24 ENERGY ONLY. TOTAL AREA 7447 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14926	15041-10000-16993	2450 S LA CIENEGA BLVD	90034	10	123B173   223	5065022002	C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2702.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.03576	-118.37759	TI-24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 3200 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14927	16041-20000-19201	18711 W SHERMAN WAY	91335	3	183B121   100	2118026019	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.20128	-118.54074	Plan check for New Fire Alarm system in 30 units appartment building. Total new fire alarm devices: 123 and 1 fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14928	19041-20000-33934	20231 W MONTERIA PARK ROAD	91311	12	207B113   327	2707003046	(Q)A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.26723	-118.5737	Plan check for PV roof mounted system, PV system size: 13.23KW wiht 42 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14929	14041-10000-09416	14105 W WEIDNER ST	91331	6	207B153   962	2617018001	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.26013	-118.44077	PV1 5KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(20)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14930	13041-20001-26302	5520 W RED OAK DR	90068	4	153B193   310	5587004007	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.11291	-118.31028	EXPEDITE FEES    <<New Rooftop PV system for an existing single family residence.  Submitted per applicant's request.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14931	16041-20000-37746	959 N SEWARD ST 4TH FLR	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.08878	-118.33338	ti to an existing commercial building.  adding new lighitng new controls to exising panels.  plan check for energy only.  total square footage 1650 in the 4th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14932	13041-10001-35586	9650 N SWINTON AVE	91343	12	201B137   676	2677013037	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.2461	-118.48598	Expedited RSES plan check per applicant request.{{PV1, Install 8.25 kW DC roof-mounted solar array for a  house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (33) modules: Rensola Solar JC250M-24/BB.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14933	15041-20000-33659	6726 N SYLMAR AVE	91405	2	180B149   129	2237003009	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			10/09/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.19294	-118.44639	Plan check for power and energy New 13 units appartment. Service size: 800ANote: 10-09-2015 Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14934	18041-10000-06569	10250 W SANTA MONICA BLVD 9290	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			PC Info Complete	03/01/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for for first time tenant, ""Glam Stop Kiosk"" retail space #9290 in Westfield Century City.  New panel for lighting and power. Total area: 200sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14935	15041-10002-38856	8500 N BALBOA BLVD	91343	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Approved	03/20/2017 12:00:00 AM	PIN	34.22443327	-118.49947932	03/20/17Changes to an approved set of plans. All change are clouded under delta 6. Changes include providing an a controlled receptacle for the kichenette, and using the general lighting circuit to feed exit & egress lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14936	13041-20000-15320	20750 W VENTURA BLVD SUITE 300	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.16638	-118.58506	T24 FOR EXISTING OFFICE SPACE. REPLACING EXISTING FIXTURES 1 FOR 1. SCOPE OF WORK: 3RD FLOOR SUITE 300. 9,759 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14937	15041-20000-37501	13090 N BORDEN AVE	91342	7	222B153    25	2504016046	RA-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM			Reviewed by Supervisor	11/17/2015 12:00:00 AM	ADDRESS	34.30817	-118.44386	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (76) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14938	19041-10000-46839	11810 W SATICOY ST	91605	2	186B169   265	2317009014	RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.20832	-118.39048	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14939	16041-10000-06387	222 S OXFORD AVE	90004	10	138B193  1427	5517008023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			Corrections Issued	02/23/2016 12:00:00 AM	ADDRESS	34.07046	-118.30775	PC FOR A NEW FIRE ALARM SYSTEM FOR A DAYCARE CENTER. SCOPE INCLUDES 36 FA DEVICES, 1 FA PANEL, AND  1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14940	14041-20003-14146	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.0352	-118.45736	(2/17/2015)  REVISIONS TO AN APPROVED SET OF PLANS.  ADDING LIGHTING FIXTURE AND EXHAUST FAN CIRCUIT.T.I. to existing building.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy.Investigation fee paid under building permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14941	18041-20000-26852	333 S GRAND AVE Suite 4350	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Title 24 only in existing high-rise building T.I. office Building. Total area: 1201 sq ft. B#18016-10000-22243	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14942	18041-20001-24405	8422 N ZEILER AVE	91402	6	192B157   445	2637014045	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM			PC Approved	07/30/2018 12:00:00 AM	ADDRESS	34.22368	-118.42536	expeditepv1install roof mounted pv system sized 7.6kw interco9nnected with msp.  5 kw battery back up.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14943	19041-10000-50719	20520 W NORDHOFF ST	91311	3	195B109    72	2780001050	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.23181	-118.58102	PLAN CHECK FOR ENERGY ONLY, T-24. REPLACEMENT OF FIXTURES WITH LED LIGHTING. INDOOR  SQ. FT. 8696 AND OUTDOOR 21150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14944	17041-20000-01535	10990 W WILSHIRE BLVD SUITE 900	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.0577	-118.44711	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 2993 SQFT HIGH RISE. SUITE 900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14945	11041-20000-16874	8147 N SAN FERNANDO ROAD	91352	6	189B173    40	2409002004	[Q]C2-2L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Issued	08/11/2011 12:00:00 AM	ADDRESS	34.21839	-118.36828	Plan check new 800A service, distribution board, and panels. All loads are future and subjected for plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14946	18041-20002-19179	4423 N SHERMAN OAKS CIR	91403	5	166-5A145  88	2283019003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	34.15116	-118.47048	08-21-2018 Changes to an approved set of plans, Changes include relocate inverters and add performance meter, all changes has been clouded. Plan check only, permit covered under Master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14947	16041-10000-01570	2029 S CENTURY PARK EAST STE 1550	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, INTERIOR OFFICE TENANT IMPROVEMENT ON 15TH FLOOR STE 1550. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 5695	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14948	16041-10003-24464			4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			Reviewed by Supervisor	03/16/2018 12:00:00 AM	PIN	34.09837718	-118.35182084	PC FOR REVISION TO SUBMITTED SET PER APPLICANT.PLAN CHECK CURRENTLY UNDER REVIEW FOR 10002 WITH YAIRTHIS IS PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14949	18041-10000-25498	1950 S AVENUE OF THE STARS	90067	5	132B161    33	4319002055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			Reviewed by Supervisor	12/04/2018 12:00:00 AM	ADDRESS	34.05947	-118.4164	FULL PLAN CEHCK FOR A NEW 41 STORY APARTMENT TOWER WITH 3 LEVELS OF SUBTERRANEAN PARKING AND 237 UNITS. SCOPE OF WORK INCLUDES NEW MEDIUM VOLTAGE SERVICE ( 5KV, 2000A, 3PH, 3WIRE). TOTAL AFFECTED AREA IS 517641 SQ. FT. B#17010-10000-03447	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14950	16041-20000-27853	2957 N VAQUERO AVE	90032	14	141A235   228	5220015002	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.08029	-118.16955	Plan check for PV roof mounted system. System size: 1.5kW with 7 modules and 7 microinverter(Enphase M515) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14951	19041-20000-43169	13907 W OXNARD ST	91401	2	177B153   781	2239016014	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	Apartment			10/23/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Issued	11/20/2019 12:00:00 AM	ADDRESS	34.17953	-118.43567	New distributon, power, and lighting for (E) building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14952	16041-10000-40784	319 E 2ND ST #117	90012	14	129A215     2	5161017034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.04929	-118.24098	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND CONTROLS FOR  A STORAGE SPACE.  TOTAL AFFECTED AREA IS 81 SQ. FT. B#16016-10000-27734	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14953	14041-20000-28101	9335 N URBANA AVE	91331	6	198B153   549	2642021042	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.23965	-118.43292	PV1.  Install 5.5 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14954	15041-20001-13350	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Expired	08/30/2017 12:00:00 AM	ADDRESS	34.01768	-118.42494	Changes to approved set.  Addition of 3 new branch circuits (hood fan, exaust fan, and supply fan).  Plan check for power and energy. Project site is an existing school. Project scope is the installation of (1) 150 kVA transformer, (1) 200-amp panel, and associated loads. The feeder on the 400-amp panel (DP-2) is being replaced, but the panel will remain in place. Submitted per applicant request. Total lighting area = 935 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14955	17041-10000-17553	5168 E HUNTINGTON DR SOUTH	90032	14	144A235   165	5219001035	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.08911	-118.16978	T24 ONLY. REPALCE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING:19500 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14956	18041-20000-07807	20653 W CHESTNUT CIR (#263)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29371	-118.58438	Plan check for a PV1 roof-mounted PV system. System size is 2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14957	10041-10000-15017	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM			PC Approved	08/06/2010 12:00:00 AM	ADDRESS	34.14436	-118.27496	T-24 lighting plan check only for lighting remodel in laboratory and office areas of the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14958	17041-10000-13053	15265 W RINALDI ST	91345	7	213B145    67	2664022030	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.27922	-118.4646	PC for energy only, Outdoor Title-24.  Removing HID fixtures and replacing with New LED. area: 10,275.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14959	14041-20000-08404	10946 N REMMET AVE	91311	12	210B105   161	2722032008	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.26933	-118.60022	PV1. Roof-mounted PV System, with 9.5kw	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14960	11041-20000-07612	2000 S AVENUE OF THE STARS 4th, 5th,-6th floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	05/18/2011 12:00:00 AM		Permit Finaled	10/13/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	T.I. to a high rise building.  Install new branch circuits, general/emergency lighting of 4th, 5th, and 6th floors.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14961	12041-20000-15656	17339 W PLUMMER ST	91325	12	201B129   445	2755017024	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.24325	-118.51294	solar system 7.2 kw single family.  Please call applicant when plan is ready for pickup.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14962	14041-10000-31435	12924 N SPROULE AVE	91342	7	222B153   221	2509012039	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.30532	-118.43512	PV1 Standard plan, 7.6kw system with (1) 7.6KW PowerOne  inverter, and (33) REC260 modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14963	19041-20000-52871	739 S HOLMBY AVE	90024	5	135B157    60	4360027021	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.06892	-118.43214	Plan check for PV roof mounted system, PV System size: 12.21KW DC with 37 PV Moduels and 1 invertere(11.4KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14964	18041-20000-38363	5262 W FOUNTAIN AVE	90029	13	144B193    51	5537012002	R3-1	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.09498	-118.30412	PV3.  Install 4.62 kW roof mounted grid tied PV system.  (14) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14965	19041-10000-51526	12500 N WOODLEY AVE	91344	12	219B137    40	2605004009	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.29864	-118.49597	PLAN CHECK FOR 3 NEW TELSA POWERWALL'S AND 3 NEW SUBPANEL'S CONNECTED TO AN EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14966	15041-20000-00781	13953 N CANDLEWOOD DR	91342	7	228B161    18	2582022014	RE11-1-H	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.32576	-118.41111	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14967	16041-10000-45725	355 S GRAND AVE STE 3200	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.05191	-118.2525	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO (E) OFFICE SPACE FOR SUITE 3200. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 11874 SQ. FT. B#16016-10000-31040	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14968	14041-10000-32453	100 E WATER ST	90744	15	027B209   299	7440010910		Harbor				9800.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	33.76645	-118.26043	(N) fire alarm control panel and (55) notification devices in (E) 2-story commercial building.  (E) initiation devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14969	19041-10000-05203	110 N CORONADO ST	90026	13	136-5A203 104	5157009027	C2-1	Central	Westlake	Echo Park		2085.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.06933	-118.27553	INSTALLING 196 NEW FIRE ALARM DEVICES AND 2 CONTROL DEVICES FOR SCHOOL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14970	18041-10000-39227	2938-2952 N ALLESANDRO ST	90039	13	150B213   787	5442024026	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	03/15/2021 12:00:00 AM		Permit Finaled	11/13/2022 12:00:00 AM	ADDRESS	34.10496	-118.24522	FULL PLAN CHECK  ONLY FOR NEW  3-STORY MIXED USE BUILDING WITH RETAIL SPACE AND 32 LIVE/WORK UNITS WITH GROUND LEVEL GARAGE. SERVICES SIZE AT 1200A 120/208V. TOTAL # OF TYP UNITS = 12, TOTAL AFFECTED AREA = 28,158 SQ. FT.PERMIT INFORMATION CAN BE FOUND ON THE ORIGINAL APPLICATION 18041-10000-15412 WHICH WAS WITHDRAWN. PERMIT FEE WILL BE ON THE INSPECTION FEE  AS PLAN CHECK WAS FOR PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14971	15041-10000-35962	5705 W 98TH ST	90045	11	093B169   270	4125024022	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Public Safety Only			10/27/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Issued	11/16/2015 12:00:00 AM	ADDRESS	33.94752	-118.3811	FIRE ALARM REPLACEMENT AND UPGRADE  PHASE IIIN A COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14972	15041-20000-20180	555 S FLOWER ST 49th Floor	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI to existing commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 6,123.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14973	14041-20001-30761	14955 W DICKENS ST 1-18	91403	4	166-5A147  52	2276004011	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			11/05/2014 12:00:00 AM			PC Approved	11/26/2014 12:00:00 AM	ADDRESS	34.15153	-118.45925	EXPEDITE PER APPLICANT REQUEST[PV2Install roof-mounted solar array on Apartment building. Interconnect with 125A subpanel. (400A main service).System size: 10kW. Grounded system. 32  305W pv modules across 4 strings (8+8+8+8).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14974	17041-20001-23830	12304 W 5TH HELENA DR	90049	11	129B141    72	4405040004	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.05325	-118.47818	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.14.66kW ungrounded system.(1) 7.7kW inverter.(1) 6kW inverter.(3) 320W AC modules.(36) 360W DC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14975	19041-20000-01804	444 S FLOWER ST #140,160	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM			PC Info Complete	01/16/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for title 24 only in existing space expansion of the restaurant, Total area: 500 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14976	10041-20000-00992	12230 W CANTURA ST	91604	2	162B165   381	2369005026	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2010 12:00:00 AM			PC Approved	01/20/2010 12:00:00 AM	ADDRESS	34.14214	-118.39983	Residential photovoltaic solar system using micro-inverter modules. Permit already issued under PCIS # 09041-20000-15552.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14977	19041-10000-46353	12500 W MAGNOLIA BLVD	91607	2	171B165   533	2357006017	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.16472	-118.4055	Energy plan check only, area of scope (1900)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14978	10041-20000-25874	11150 W SANTA MONICA BLVD #440	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	12/30/2010 12:00:00 AM		Permit Finaled	03/16/2011 12:00:00 AM	ADDRESS	34.04704	-118.44563	T.I. to existing high rise building partial of 4th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14979	16041-10000-44081	6871 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	33.93198	-118.41079	PC FOR T24 ONLY ON TI FOR OFFICE BUILDING. INSTALLING NEW LIGHTS, RECEPTACLES AND PANELS; LOAD UNDER 400A. TOTAL AFFECTED AREA IS 1236 SQFT.ALTERATIONS MADE IN INDIVIDUAL ROOMS; NO ALTERATIONS TO PATH OF EGRESS. Building application under 16016-10000-28607	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14980	14041-10002-27847	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	8/12/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  TEMPORARY POWER FOR BAGGAGE HANDLING.7/24/2015 PLAN CHECK FOR CHANGES TO SET OF PLANS DELTA 1 AND DELTA 2. RESHUFFLING OF LOADS AND RELOCATION OF PANELS. NO NEW LOADS HAVE BEEN ADDED. ((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX TERMINAL 1. CHANGING OF THE POWER DISTRIBUITION SYSTEM AND LIGHTING.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14981	13041-10000-18601	8201 W BEVERLY BLVD STE300	90048	5	138B173   380	5514008046	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	34.07624	-118.36815	permit to be pulled at EPC counter only. PC for energy only with emergency lighting. less than 400A and not a hirise per applicant. suite 300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14982	14041-20002-12043	12655 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	33.97753	-118.41457	REVISIONS TO AN APPROVED SET OF PLANS.  REMOVAL OF SMS MONITORING SYSTEM.pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #3. 3/3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14983	17041-10000-18451	2049 S CENTURY PARK EAST 34TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK FOR TITLE 24 ONLY(TI-HIGH RISE BUILDING) - SCOPE INCLUDES NEW LIGHTING WITH CONTROLS. TOTAL 3005 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14984	15041-20000-23842	9750 N WOODMAN AVE	91331	6	201B149   304	2647028103	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.24804	-118.44858	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement: power and lighting area within a consultion room. Total lighting area = 96 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14985	16041-10000-30820	621 W ROSECRANS AVE	90248	15	075B201    35	6132006031	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	33.90205	-118.28562	FEES ARE $0 DUE TO SENATE BILL 1222. an interactive photo voltaic system will be installed on roof. total of 803 modules and 6 inverters. total system size is 216kw AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14986	16041-40000-18576	13622 W HART ST	91405	2	183B157   511	2328010006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.19746	-118.42985	Standard plan is usedPV1, NSTALL NEW 3.924 KW DC ROOF-MOUNTED SOALR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES:SUNPOWER SPR-E20-327-C-AC(12)MICROINVERTERS: THE SAME BRAND	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14987	12041-10000-13375	505 S VIRGIL AVE	90020	4	135B197   873	5077004028	R4P-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.0649	-118.28724	"PLAN CHECK POWER AND ENERGY FOR EXISTING THREE STORY BUILDING.  CHANGE OF USE TO MEDICAL BUILDING. TWO  2000A SERVICES SUPPLYING BUILDING IN METHANE ZONE. ""COMPLY WITH DEPARTMENT ORDER effective date11/30/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14988	15041-20000-43543	5449 N WAMEDA AVE	90041	14	165A227   124	5691019033	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.14567	-118.19484	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(24)MODULES-SOLARWORLD SW 285 MONO BLK(1)INVERTER-SUNNYBOY SMA SB6000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
14989	16041-20000-18893	4612 N VAN NOORD AVE	91604	2	168B161   866	2362005008	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	PIN	34.15439689	-118.41461249	PV1.  Install 15.3 kW roof-mounted PV system.  (48) 320W PV modules with (1) 11.4 kW central inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14990	12041-20000-01824	16311 W VENTURA BLVD STE 580	91436	5	168B137   359	2260009038	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	ADDRESS	34.15723	-118.48856	REMODEL INTERIOR T.I. TO (E) MED. OFFICEArt. 517 project, Ambulatory Surgical, tenant space in an exist. hi-rise bldg. including a generator in a separate location at the parking garage (Bldg. permit under PCIS 12016-20000-01178)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14991	12041-10000-09476	770 W WILSHIRE BLVD 3RD FLOOR	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	34.04914	-118.25811	RETROFITTING EXISTING 119 2X4 FIXTURES WITH LED RETROFIT KIT ON 5th FLOOR OF 9 FLOOR BUILDING. ENTIRE 5th FLOOR (NO SUITE NUMBER).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14992	16041-20001-40271	3100 W 3RD ST	90020	13	136-5A201 170	5501022026	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.06844	-118.28464	Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 30kW (6kW*5) ungrounded system. (105) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14993	17041-10000-00560	719 E 25TH ST C	90011	9	120A209   250	5131023022	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Expired	09/17/2023 12:00:00 AM	ADDRESS	34.02228	-118.26008	PV2, INSTALL NEW 2.12 KW DC ROOF-MOUNTED SOLAR SYSTEM FOR MULTI-FAMILY HOUSE .(8)MODULES: AXITEC AXLPOWER AC-265P/156-60(1) INVERTER:FRONIUS GALVO 2.5-1	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
14994	19041-10000-10641	1950 S NAOMI AVE	90011	9	120A211   286	5129005020	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.02205	-118.24865	Remove HID fixtures and replace with new LED fixtures (Outdoor Only), - T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14995	16041-20000-24350	20550 W NORDHOFF ST	91311	3	195B109    71	2780001048	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Expired	10/05/2018 12:00:00 AM	PIN	34.23146358	-118.5819732	Plan check Title 24 only in existing space T.I. Total area: 18,417 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14996	13041-10000-28804	6904 N VANTAGE AVE #106	91605	2	183B165   722	2321010***	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.19578	-118.39751	PV1, ROOF-MOUNTED PHOTOVOLTAIC SYSTEM SIZE IS 5KW DC TRANFORMERLESS, WITH (20) MODULES: TRINA SOLAR #TSM-250PA05.18(1)POWER-ONE #AURORA PVI-4.2-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
14997	10041-20000-20967	15180 W BLEDSOE ST	91342	7	222B145   139	2506002017	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	12/02/2010 12:00:00 AM		Permit Finaled	03/30/2011 12:00:00 AM	ADDRESS	34.3063	-118.46389	PLAN CHECK FOR POWER FOR NEW EQUIPMENT, SWITCHBOARDS, PANELS, AND XFMRS TO EXISTING MEDIUM VOLTAGE SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
14998	16041-10000-26475	7801 W SUNSET BLVD	90046	4	147B177   968	5551020001	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.09825	-118.35955	PC for title 24 for commercial TI with floor area of 698 sqft. Installing 23 light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
14999	16041-20000-41331	5998 W PICO BLVD	90035	10	129B173   351	5068012001	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM			PC Approved	11/22/2016 12:00:00 AM	ADDRESS	34.05216	-118.371	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT. CHANGE OF USE TO RESTAURANT. 1387 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15000	13041-10002-04211	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			03/20/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	34.06209	-118.34912	Changes to approved set of plans: LED ndercabinet lighting added to kitchens. Some mechanical power changes. Lighting changes. List of changes to plans provided.Plan check power and energy for 125 residential units and 50 joint/live work units apartment building over three level basement parking garage. 5000A service supplying building. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15001	11041-20000-01108	3844 S MOTOR AVE	90232	10	117B165   171	4208006025	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Public Safety Only			01/19/2011 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.01945	-118.40297	Plan check for new fire alarm system in apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15002	14041-20000-05777	1727-1729 N LUCILE AVE	90026	13	145-5A203 139	5429016010	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM				New 3 story over 5-car parking garage.  Install new subpanels.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15003	12041-10000-02732	8500 W BEVERLY BLVD # 783	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM			PC Approved	02/06/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) RETAIL SPACE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15004	14041-10000-08372	9002 N SEPULVEDA BLVD	91343	7	195B145   654	2654004052	[Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.23463	-118.46726	TI TO (E) STARBUCKS.  1 STORY. LESS THAN 400A. fees under inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15005	10041-10000-07276	1879 N VERMONT AVE	90027	4	150B197   912	5589028040	C4-1D	Central	Hollywood	Greater Griffith Park		1892.00	Electrical	Electrical	Commercial			04/21/2010 12:00:00 AM	04/23/2010 12:00:00 AM		Permit Finaled	07/14/2010 12:00:00 AM	ADDRESS	34.10526	-118.292	T.I. for existing restuarant.  Install general and emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15006	19041-20000-17681	550 S HILL ST #1635	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	02/03/2020 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.04753	-118.25268	Plan check for Title 24 energy only in existing high-rise building Tenant Improvement on suite number 1635 Total area: 1035 sq ft.B#18016-10000-40994	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15007	15041-20000-29551	7015 N SHADE TREE LANE	91307	12	183B085    86	2031007***	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Expired	10/03/2017 12:00:00 AM	ADDRESS	34.1992	-118.65881	Plan check for PV roof mounted system. System size: 7.6kW with 35 modules and 1 inverter(7.6kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15008	13041-20001-13789	10224 S BROADWAY PV 2	90003	8	091-5A203 314	6053028023	RD1.5-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	33.943	-118.27796	((( PV2 FOR CONDO. EXPRESS PERMIT HAS ALREADY BEEN PULLED, THIS IS A PLAN CHECK ONLY. TRANSFORMERLESS SYSTEM. 12 PANELS AND 1 INVERTER. TOTAL SYSTEM SIZE 3.93KW.)))INSTALL PHOTOVOLTAIC SOLAR SYSTEM AND MONITORING DEVICE.  3.93 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15009	15041-20000-01896	1728 N GLENDALE BLVD	90026	13	142-5A209  30	5423008013	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.08658	-118.25954	"TI TO AN EXISTING SINGLE STORY COMMERCIAL OFFICE BUILDING. NEW LIGHTING AND CONTROLS.  USING NEW PANEL, LOAD <50KVA.  TOTAL SQUARE FOOTAGE 1200.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.""COMPLY WITH DEPARTMENT ORDER effective date 09/18/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15010	17041-10000-22126	3000 W LEEWARD AVE	90005	1	132B197   364	5077018011	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.05857	-118.28933	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING HIGH RISE BUILDING FOR 204 UNIT APPARTMENT. SCOPE OF WORK INCLUDES CHANGING PANELS AND REPLACING BREAKERS(204 UNITS),  AND FIXTUES(LED) USING EXISTING CIRCUIT IN COMMON AREA . TOTAL AFFECTED AREA = 9607 SQ. FT.Phase 1: 17071-10000-21304Phase 2: 17071-10000-22126	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15011	17041-20003-12060	7501 N GLENOAKS BLVD	91504	2	186B181   296	2401042013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.04	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Approved	10/23/2018 12:00:00 AM	ADDRESS	34.20677	-118.34209	Revisions to approved set of plans to reflect field revisions.  New subpanel supplying rooftop lighting circuits.  Approval for clouded changes on E-1 and E-6 only. (((Revisions to approved set of plans to reflect field revisions.  Revised pool area and roof lighting.2/23/2018changes to an approved set of plans.  changes to reflect field conditions.  changes noted delta 1.this is plan check only.  no new equipment.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15012	19041-10000-30540	15301 W VENTURA BLVD	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.15411	-118.46654	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND EQUIPMENT IN AN ELECTRICAL ROOM. PERMIT FEES HAVE BEEN PAID FOR UNDER APPLICATION # 18041-10000-32123 / X18LA14978. 75 KVA TRANSFORMER TO BE PAID FOR UNDER THIS APPLICATION. TOTAL SQ. FT. 339.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15013	19041-20000-36628	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.06338	-118.20434	T24 ENERGY PLAN CHECK FOR EXISTING COMMERCIAL OFFICE BUILDING. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 322 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15014	17041-30000-26210	171 S LA BREA AVE	90036	5	138B181  1180	5513019039	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			PC Info Complete	08/10/2017 12:00:00 AM	ADDRESS	34.07163	-118.34424	Plan check for Title 24 only in existing retail space. Total area: 2,134 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15015	14041-20001-13851	8942 N COLLETT AVE PV1	91343	12	195B141   217	2672003035	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.23318	-118.48385	($0 permit due to senate bill 1222 from 2012INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 5.1 KW USING 5KW INVERTER/S. plan check for pv system and permit for 4 additional panels. total installation 24 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15016	15041-10001-14256	17260 W LAHEY ST	91344	12	210B133   399	2697006012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM			Reviewed by Supervisor	05/19/2015 12:00:00 AM	ADDRESS	34.27291	-118.50979	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15017	17041-10000-23749	19801 W NORDHOFF PL	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.23568	-118.56464	T-24, REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 6600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15018	12041-20000-00418	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM	08/01/2013 12:00:00 AM		Issued	08/01/2013 12:00:00 AM	ADDRESS	33.74512	-118.26099	Install two new 600 ampere MCC in non classified areas, and new motors and associated circuits in hazardous classified areas, Class 1 Div 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15019	19041-10000-32276	1724 W PACIFIC COAST HWY	90717	15	033B193    50	7553018029	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	33.7893	-118.30825	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15020	11041-20000-24406	1000 W WILSHIRE BLVD Ste 2100-& 2150	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM			PC Approved	11/15/2011 12:00:00 AM	ADDRESS	34.05085	-118.26078	T.I.  Existing office space.  Remodel of light fixtures i suites 2100 and 2150.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15021	17041-10000-44778	4510 N BLACKFRIAR ROAD	91364	3	165B097    49	2076012033	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.15203	-118.62313	PC for rooftop solar for 13.2kW. Installing 39 panasonic modules with optimizers and two SMA central inverters (SB7.7 and SB5). Note J-Box plug on SLD is for future energy monitoring equipment.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15022	11041-20000-01279	7238 N VARNA AVE	91605	2	186B157   619	2328028009	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	ADDRESS	34.20239	-118.42457	T.I. to existing building.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15023	19041-10002-06939	3931 S LYCEUM AVE	90066	11	111B153  1286	4236023013	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			Reviewed by Supervisor	03/04/2019 12:00:00 AM	ADDRESS	33.99621	-118.4399	THIS SUPP IS FOR THE BATTERY PORTION OF THIS PROJECT. PC for ROOF MOUNTED PV ON SFD.System includes (21) modules (REC solarr: RETP2), (21) 320 solar edge optimizers, (1) LG chem 5kw battery, (1) solar edge 7600 inverter. (1) load panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15024	15041-20000-06074	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	34.21499	-118.4422	Plan check for T-24 outside light for Rexford Industrial, LLC. Total area: 2297 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15025	17041-10001-26338	3783 E UNION PACIFIC AVE	90023	14	118-5A229 211	5191028039	MR1-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.01666	-118.19362	Supplemental PC for new fire alarm system with one fire alarm panel, one annunciator and 44 fire alarm devices. Express permit pulled under master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15026	19041-20000-02215	8734 S FIGUEROA ST	90003	8	096A201   120	6038002047	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	33.95775	-118.2825	Plan check for new fire alarm system, for 3 story building 5 units apartment. Total Fire alarm devices: 26  and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15027	16041-10000-21926	18010 W CHATSWORTH ST	91344	12	207B125   637	2731008***	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.26474	-118.52445	TI to an (E) Ralphs, install new lights and receptacles in the clicklist area. PC for T-24 only. Total area: 2,005 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15028	14041-10000-08921	7634 N HINDS AVE	91605	6	186B169   135	2317006007	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Expired	05/06/2016 12:00:00 AM	ADDRESS	34.20945	-118.39093	PV1, INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(13) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15029	17041-10000-32274	5889 1/2 S TOWNE AVE	90003	9	105B205    96	6006030017	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	07/07/2018 12:00:00 AM	ADDRESS	33.98743	-118.26761	PC FOR PV SYSTEM. TOTAL OF 11 MODULES AND CENTRAL INVERTER 3.8KW USING CENTRAL INVERTER WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15030	15041-10000-07339	4378 N WOODMAN AVE	91423	4	165B157   346	2360006001	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.15015	-118.43103	REMODEL EXISTING RESTAURANT-ALTERAION OF LIGHTING SYSTEMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15031	18041-20000-38103	9561 N O'MELVENY AVE	91331	7	201B161   916	2626012007	RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.24355	-118.41177	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15032	18041-10000-36175	3222 W SLAUSON AVE	90043	8	108B185   910	4005005028	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	33.98885	-118.32898	PLAN CHECK FOR FIRE ALARM SYSTEM FOR FOR REPLACEMENT OF EXISTING FIRE ALARM PANEL AND DEVICES - NEW EQUIPMENT CONSIST OF 1 FIRE ALARM PANEL AND 64 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15033	18041-10000-44499	333 S HOPE ST 20th Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC FOR TI TO AN EXISTING OFFICE SPACE. TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15034	13041-20000-21483	10155 N CANOGA AVE	91311	12	204B105   476	2747010022	[T][Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	ADDRESS	34.25509	-118.59748	RENOVATION OF EXISTING OFFICE SPACE. NEW LIGHTING AND CIRCUITS. PLAN CHECK FOR T24 ENERGY ONLY. TOTAL AREA 956 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15035	14041-20000-18512	9871 N LEV AVE	91331	6	201B153   238	2645008047	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Expired	08/25/2016 12:00:00 AM	ADDRESS	34.24972	-118.43288	New roof mounted PV system with Enphase Microinverter, model M215-60-2LL.  Total system size is 4KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15036	17041-10000-45956	20128 W ROSCOE BLVD	91306	3	192B113   604	2107001021	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Issued	12/22/2017 12:00:00 AM	ADDRESS	34.22002	-118.57186	REPLACE METAL OUTDOOR HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15037	14041-20001-05275	20902 W AVENUE SAN LUIS	91364	3	171B109   181	2167021007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.16451	-118.58862	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15038	09041-20003-10547	100 S THE GROVE DR	90036	4	138B177   451	5512004908	OS-1XL-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/01/2010 12:00:00 AM			PC Approved	10/01/2010 12:00:00 AM	ADDRESS	34.0746	-118.35615	Plan check only. Revision delta 17 to approved plans permit # 09041-20000-10547. Plan check to revise area control for media room and audio room via lighting control panel (relay zone control)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15039	13041-10000-02931	221 S FIGUEROA ST	90012	9	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.05628	-118.25373	REPLACEMENT OF EXISTING FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15040	11041-10000-18014	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I.  Exising furniture store to be gutted and occupied by a different furnitire store (Ashley Furniture Homestore).  Applicant states that no new load will be added.  Plan check is for energy only on a 34,019 sq ft store using the performance method..NOTE: AT VERIFICATION , ENGINEER INDICATED THAT ALL CIRCUITS SHOWN ON THE PANEL SCHEDULES ARE NEW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15041	16041-10000-18099	12746 W JEFFERSON BLVD BLDG B	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			PC Info Complete	05/23/2016 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR BUS EXTENSION. ADDING 800A SECTION. PROVIDING TAP TO ADDED SECTION. NO OTHER CHANGES OR LOADS AT THIS TIME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15042	12041-20000-16147	3651 S TROUSDALE PKWY	90089	8	118-5A201  22	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.01922	-118.28617	Energy plan check zumberge hall usc.(permit issued under inspection)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15043	11041-20000-17590	9724 W OAKMORE ROAD	90035	5	129B165   777	4307017012	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2011 12:00:00 AM	09/12/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.04767	-118.39957	NEW ROOF MOUNTED 6.67KW PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15044	18041-10000-03931	6160 N CARTWRIGHT AVE	91606	2	177B177   303	2414016002	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.18268	-118.36362	REPLACE OUTDOOR AND INDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 52450 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15045	16041-10000-15676	5150 W HOLLYWOOD BLVD	90027	13	148-5A195  92	5544015014	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.10161	-118.30232	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING COMMERCIAL BUILDING (BAKERY CAFE). SCOPE INCLUDES NEW LIGHTS RECEPTACLES FOR THE CUSTOMER AREA, RESTROOM, AND KITCHEN AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15046	16041-20000-35273	19731 W ROMAR ST	91311	12	204B117   367	2726007013	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.25465	-118.5634	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter, (24) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15047	16041-10001-41309	1717 E 7TH ST	90021	14	124-5A215  56	5164022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM			PC Approved	06/30/2017 12:00:00 AM	ADDRESS	34.03495	-118.23573	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION UNDER DELTA 1. SCOPE INCLUDES REMOVAL OF RECEPTACLES AND EXIT LIGHTS AND RELOCATION OF LIGHTING CONTROLS. ALL CHANGES COLUDED ON PAGES E3.0 E2.0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15048	17041-10000-03579	300 S GRAND AVE # LP160	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	PIN	34.05243427	-118.25124731	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2416 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15049	14041-20000-33927	1550 S GLENVILLE DR	90035	5	129B165   411	4306017020	R1-1	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.05095	-118.39304	PV1. ROOFMOUNTED SOLAR SYSTEM. MICRONINVERTER NON STANDARD PLAN. SYSTEM SIZE: 5.5 KW(20) SOLAR WORLD SW275 MODULES(20) ENPHASE M250 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15050	10041-10002-12198	6725 W SUNSET BLVD # 250,260	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM			PC Approved	09/27/2010 12:00:00 AM	ADDRESS	34.09814	-118.33717	ADDING & RELOCATING OUTLETS LUMINAIRES;PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15051	18041-20000-29953	3831 S HUGHES AVE	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.02242	-118.39823	Plan check for power only install 300KVA Transformer and 1000A panel board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15052	16041-10000-08297	5001 W WILSHIRE BLVD #104-#105	90036	4	135B185   544	5507019029	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.06229	-118.33908	T-24, CHANGE OF USE FROM RETAIL TO A TAKE OUT JUICE SHOP. SCOPE OF WORK INCLUDES NEW ELECTRICAL EQUPMENT, LIGHING AND RECEPTACLES. TOTAL SQ. FT. 1379.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15053	17041-10000-19435	6811 N DE SOTO AVE	91303	3	183B109   873	2138029900	(WC)RIVER-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1349.03	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.19433	-118.58869	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15054	19041-10000-41546	1100 N NORTH MAIN ST	90012	1	135A217   147	5409010031	UC(CA)	Central	Central City North	Historic Cultural North		2060.10	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Info Complete	10/11/2019 12:00:00 AM	ADDRESS	34.06328	-118.23339	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI IN AN EXISTING COMMERCIAL SPACE. SCOPE OF WORK INCLUDES ADDING NEW LIGHTS, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2068 SFQT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15055	18041-20002-44288	15840 W VENTURA BLVD unit 100	91436	5	168B141   638	2283009012	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Issued	08/16/2019 12:00:00 AM	ADDRESS	34.15548	-118.47886	Revision to approved plans.  Change of voltage class from 208Y/120V 3ph-4w to 240/120V 1ph-3w.  New panelboards.  Recircuiting of loads.  Approval for revised sheets under delta-5.  (((ti to an existing dental office.  plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15056	10041-20000-11292	13654 W BURBANK BLVD	91401	2	174B157   609	2344001013	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	09/20/2010 12:00:00 AM	ADDRESS	34.17195	-118.43085	T I lighting and power in store. P/C  for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15057	13041-10000-21229	1119 W PACIFIC COAST HWY	90744	15	036B201   750	7414024016	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	33.79059	-118.27706	TENANT IMPROVEMENT FOR DOLLAR TREE STORE; PLAN CHECK IS FOR POWER AND TITLE-24. UPGRADING SERVICE TO 600A. ONLY PNL-A IS USED; PNL-B & PNL -C WILL BE USED IN THE FUTURE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15058	14041-10000-23113	7712 N DENSMORE AVE	91406	6	189B141   267	2206011029	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.21086	-118.47699	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 8164 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15059	13041-10000-26832	11918 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.05238	-118.4706	Title 24, for one story retail, located in basement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15060	15041-20001-09703	6250 N TOPANGA CANYON BLVD #1540 B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	09/29/2015 Changes to an approved set of plans. Lighting control diagram has been updated to reflect the one installed on the field. This supplemental plan check does not cover any changes made to the Title 24 Compliance Forms or the lighting floor plan.*****Previous Work Description*****Plan check for power and Title-24 (energy).  Total area = 4,904 sq. ft. (indoor) and 90 sq. ft. (outdoor)T.I. to retail space.  First time tenant.  Three new panels and one 75 kVA transformer.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15061	14041-20000-28836	5340 N DENNY AVE	91601	2	171B177   204	2416026003	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			10/17/2014 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.16783	-118.36414	NEW (8 UNIT) APARTMENT BUILDING 3-STORY OVER SUBTERRANEAN GARAGE400A SERVICE. PLAN CHECK FOR ENERGY ONLY FOR PARKING GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15062	18041-10000-33443	2029 S CENTURY PARK EAST # 2070	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR OFFICE TI  1090 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15063	19041-10000-45590	6350 W 3RD ST	90036	4	138B177   796	5509018009	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.07119	-118.36054	Energy Plan check only, Area of scope (555)Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15064	13041-10005-30473	1891 N ACADEMY DR	90026	1	141B213    20	5415005902	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM			PC Info Complete	09/02/2016 12:00:00 AM	ADDRESS	34.08305	-118.2417	PC FOR INSTALLATION OF FIRE PUMP SERVICE. ALL PERMIT FEES PAID FOR. FIRE PUMP WILL NOW BE INSTALLED ON DEDICATED FP SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15065	15041-10000-32160	20790 W NORDHOFF ST	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Expired	10/25/2017 12:00:00 AM				NEW FIRE ALARM PANEL FOR A SPRINKLER MONITORING SYSTEM. PC PER APPLICANT'S REQUEST. FIRE ALARM DEVICES PAID UNDER EXPRESS PERMIT #15041-10000-10945.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15066	18041-20000-24786	3309 S LA CIENEGA PL	90016	10	120B173   158	4205034007	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.02871	-118.37528	Plan check for power and energy for change of use from warehouse to offices multiple tenant spaces. Total newly connected load exceed 400A. Total area: 29,017 sq ft. B#17016-20000-20147	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15067	16041-20003-23116	11711 W PICO BLVD	90064	11	123B149   653	4260029033	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM			PC Approved	07/11/2018 12:00:00 AM	ADDRESS	34.03159	-118.44613	07/11/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the lighting floor plans and have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****New plan design for lighting system for office/art studio remodel.  Plan check for energy. (((PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF ART STUDIO. 958 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15068	16041-10000-03324	9537 S BANDERA ST	90002	15	093A215   187	6048034026	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	33.94936	-118.23977	PV1, NEW 3.0KW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MODULES: KYOCERA KU2606XPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15069	15041-10001-09040	523 W 7TH ST	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM			PC Approved	09/25/2015 12:00:00 AM	ADDRESS	34.04717	-118.25611	((9/25/2015- REVISE T24 TO MATCH INSTALLED))TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 1430.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15070	17041-10000-23249	11151 W VANOWEN ST	91605	2	183B173   261	2319005036	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.19409	-118.37403	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15071	16041-10000-00546	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.09783	-118.36466	ADD NEW DISTRIBUTION BOARD AND EQUIPMENT FOR FUTURE TENANT.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15072	14041-10000-33356	1053 W SUNSET BLVD	90012	1	135A211    97	5406030040	C2-2D	Central	Central City North	Historic Cultural		1977.00	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.06492	-118.2487	Power plan check for a 600-Amp service upgrade and a new 200KW generator installation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15073	17041-10000-46484	552 W 121ST ST	90044	15	084B201  1346	6117005002	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	33.92239	-118.28476	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 11 MODULES ( HANWHA Q-CELL. Q PEAK-G4.1 305), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS) WITH A CENTRAL INVERTER (SOLAR EDGE SE3000H-US). SYSTEM SIZE IS 3.355 KWdc AND 3KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15074	16041-10000-05397	22222 W VICTORY BLVD BLDG A	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUNDRY ROOMS.  TOTAL AFFECTED AREA IS 2475 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15075	15041-20000-18588	16534 W GREENLEAF ST	91436	5	168B137   511	2284005012	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.15575	-118.49345	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (26) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15076	19041-10000-45640	590 S BURLINGAME AVE	90049	11	129B141     1	4264008001	A1-1XL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	04/14/2020 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.04606	-118.48522	PLAN CHECK FOR TITLE-24. SCOPE OF WORK INCLUDES ADDITIONAL FIXTURES CIRCUITS TO AN EXISTING SPACE. TOTAL AFFECTED AREA: 1985 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15077	17041-10000-02866	13705 W VENTURA BLVD	91423	4	165B157   603	2271018008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.14823	-118.43147	Plan check fot Title 24 only in 3 existing space T.I. to restaurant. Total area: 1,900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15078	17041-20000-05571	17270 W DEVONSHIRE ST	91325	12	204B133   195	2694015006	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			Reviewed by Supervisor	03/03/2017 12:00:00 AM	ADDRESS	34.2574	-118.51061	PV1.  Install 13.86 kW roof mounted grid tied PV system.  (44) modules with (2) 6.6 kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15079	12041-10000-18307	22048 W RAYEN ST	91304	12	195B101   167	2010006040	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.23107	-118.60754	Plan check for PV, single family dwelling. SOlar Edge Power box included (+1 PC hour for submittal and  +1 Miscellaneous Permit for permit fee period). 3.84kW PV Array.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15080	19041-20000-01212	13356 W WASHINGTON BLVD	90066	11	108B153  1311	4230008056	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	PIN	33.99199935	-118.44390738	T-24 FOR TI TO (E) RETAIL SPACE, SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES, TOTAL SQUARE FOOTAGE = 1316	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15081	18041-10000-16984	6750 W SUNSET BLVD	90028	13	147A185    92	5547021021	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Info Complete	05/08/2018 12:00:00 AM	ADDRESS	34.09769	-118.33815	INSTALL A NEW PAY STATION IN THE DRIVE TRU AREA OF A RESTAURANT.PLAN CHECK FOR T-24 ENERGY ONLY -  REQUESTED BY THE INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15082	18041-20000-17401	15044 W NORTHWIND LANE	91343	7	198B145   463	2651001***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.23862	-118.46008	Plan check for a PV1 roof-mounted PV system. System size is 4.6 kWac and consists of (1) inverter and (19) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15083	15041-20000-31020	2496 S CENTINELA AVE	90064	11	120B149   358	4257020034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Apartment			09/18/2015 12:00:00 AM			Reviewed by Supervisor	10/23/2015 12:00:00 AM	ADDRESS	34.02592	-118.45089	Plan check power and energy for New 5 units appartment with service size 600A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15084	17041-10000-03574	3043 S DENISON AVE	90731	15	009B197  1607	7465026010	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.71619	-118.28901	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(16)MODULES-HANWHA Q-CELL Q PRO L(16)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15085	17041-10000-31013	1814 N MARCHEETA PL	90069	4	150B169  1243	5561008029	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.10506	-118.38903	NEW SFD. PC FOR POWER ONLY. SCOPE INCLUDES A NEW 600A 120/240 1 PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. B# 14010-20000-01774.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15086	14041-20001-20250	8956 W WONDERLAND PARK AVE	90046	4	153B169   501	5564019053	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM			Plans on Hold	07/29/2014 12:00:00 AM	ADDRESS	34.11469	-118.39031	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 5.2 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS.Zoning clearance obtained under plan check application 14041-20000-20204	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15087	18041-10001-26977	3780 S WATT WAY	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Issued	03/08/2019 12:00:00 AM	PIN	34.01877902	-118.28765493	CHANGES TO AN APPROVED SET OF PLANS. CHANGES REMOVING/ADDING FA DEVICES, REVISING RISER DIAGRAM, FLOOR PLANS, AND BATTERY CALCULATIONS. ALL CHANGES ARE UNDER DELTA 5 & 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15088	10041-20001-21455	13691 W VAUGHN ST	91340	7	213B157   825	2523003004	M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM			PC Approved	02/17/2011 12:00:00 AM	ADDRESS	34.27657	-118.43239	PLAN CHECK ONLY FOR MISSING SE, S2, AND FUTURE TRAILER PANELS, FC AND HP EQUIPMENT, AND LIGHTING FIXTURES NOT INCLUDED ON APPROVED PLANS. NO CHANGE TO LOAD AND T24 CALCULATIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15089	17041-10000-20162	4520 N SEPULVEDA BLVD	91403	4	166-5A145  60	2276040018	C2-1VL, R4-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.15175	-118.46686	Title 24 plan check.  Replace HID fixtures with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15090	14041-20000-04487	714 N GENESEE AVE	90046	5	141B177   496	5527008009	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.08432	-118.35829	New roof mounted PV system with 4.08KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15091	16041-10000-09945	1902 E MARENGO ST STE. 105-106	90033	14	132A223    33	5201016003	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.05756	-118.21009	TI to an (E) Walgreens, install lightings and receptacles. Two new panels 0-200A with less 200A new load. PC for Energy only. Total area: 1,894 sq. ft. Fire alarm is not part of the scope of this permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15092	11041-20000-27268	15355 W SHERMAN WAY	91406	6	183B145    36	2222027039	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM			PC Approved	02/07/2012 12:00:00 AM	ADDRESS	34.20139	-118.46803	Convert existing retail space to yougurt shop occupying suites # Q and R.  No new lighting installed and no modification to the existing lighting systems of suites Q and R.  Per applicant's request, plan check is for power only.  Existing permits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15093	18041-10001-43636	5171 N OTIS AVE	91356	3	171B125   421	2161019013	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM			PC Approved	11/28/2018 12:00:00 AM	ADDRESS	34.16516	-118.53565	EXPEDITE FEES.NEW ROOF MOUNTED 15 kW AC KW PV SYSTEM WITH 56 PV MODULES AND OPTIMIZERS  ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15094	12041-10001-16921	1801 S FIGUEROA ST	90015	9	124-5A205 281	5126002008	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.03524	-118.27179	"PLAN CHECK FOR POWER AND ENERGY FOR NEW 1-STORY BUILDING STRUCTURE W/ MEZZ AT 1ST LEVEL. GROUND LEVEL OFFICE AND SHOW ROOM FOR MERCEDES BENZ DEALERSHIP.  BUILDING IN METHANE ZONE. NEW 3000 AMP SERVICE. 2500A FEEDER SUPPLYING BUILDINGS MERCEDES BENZ BUILDING.  THIS APPLICATION IS FOR  PORTION""B"".  PORTION ""A"" WAS SUBMITTED UNDER 12041-10000-16921."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15095	11041-10000-08581	16325 W VENTURA BLVD	91436	5	168B137   354	2260009045	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	34.15731	-118.48907	RALPHS GROCERY STORE.  T.I.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15096	13041-10000-15093	7020 N WOODMAN AVE	91405	2	183B157   423	2328009037	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			06/10/2013 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Closed	06/12/2017 12:00:00 AM	ADDRESS	34.19821	-118.43105	New 3 story 24-unit apartment building with one level subterranean parking.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15097	17041-10000-03109	7521 W MULHOLLAND DR	90046	4	156B177   200	2427005022	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	ADDRESS	34.12575	-118.35915	PC FOR POWER. PROPOSED NEW 2-STORY SFD WITH ATT. 3-CAR  GARAGE. 600A SERVICE 240/120 V. B # 14010-20000-01953	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15098	14041-10001-13989	1001 N ENCHANTED WAY	90272	11	132B121   490	4419003018	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.05479	-118.54922	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15099	18041-20000-33428	20704 W BEECH CIR #291	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.29249	-118.58443	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15100	14041-10001-09287	324 S JUNE ST	90020	4	135B185   154	5505003003	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.06802	-118.33405	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 2 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3000A-US-ZB-U. (8) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15101	19041-20000-26170	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Closed	09/16/2019 12:00:00 AM	ADDRESS	33.93845	-118.42964	"PC FOR TEMP INSTALLATION OF 800KVA GENERATOR ONLY. GENERTATOR TO PARTIALLY ENERGIZE  ""MDB""CLOUDED DELTA 10 ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15102	13041-10000-35832	5858 N SHOUP AVE POOL BLDG	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM			PC Info Complete	06/06/2014 12:00:00 AM	ADDRESS	34.17705	-118.6144	PLAN CHECK FOR POWER AND ENERGY FOR NEW POOL BUILDING.   (4 OF 4 ) ALL FEES FOR ENERGY ARE UNDER APPLICATION # 13041-10000-35818.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15103	19041-20001-08232	7536 N LOMA VERDE AVE pv1	91303	3	186B109   352	2112001008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.20755	-118.58947	07-01-2019 Changes to an approve set of plan, Changes include relocate inverter, disconnect, service entrance. All changes has been clouded as delta B. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15104	18041-10000-35997	131 N MARTEL AVE	90036	5	138B181   696	5512011012	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.07458	-118.35123	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP.  TOTAL SYSTEM SIZE IS 8.28KWdc / 7.36KWac.(23)AC MODULES-SUNPOWER SPR-X22-360-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15105	18041-20001-02524	4922 W PICO BLVD	90019	10	129B181   990	5070019032	C2-1-O	Central	Wilshire			2172.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	34.0478	-118.34372	plan check for indoor energy only, retail space.  total square footage 1093.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15106	13041-20003-21950	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM			PC Approved	10/29/2014 12:00:00 AM	ADDRESS	34.2312	-118.36756	REVISIONS TO AN APPROVED SET OF PLANS.  ADDING THREE FUSE DISCONNECTS TO PANELS Q, 1A, AND 1B.DEMO INTERIOR OF FORMER RALPHS MARKET. CREATE 7 NEW LEASE SPACES, 3 OF THEM SHELL ONLY AND THE REST TI IMPROVEMENTS. REMODEL EXTERIOR CANOPY AND PARKING LOT. NEW 120/208 2500A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15107	13041-20000-15896	7712 N BECK AVE PV-1	91605	6	189B169   925	2316004010	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.21064	-118.38329	PV-1. One 3kW inverter. transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15108	15041-20000-21636	14325 W BLEDSOE ST	91342	7	228B149    15	2502025004	RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.32335	-118.44558	Plan check for PV roof mounted system. System size: 11kW with 44 modules and 2 inverters(4.0kW and 7.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15109	16041-20000-01224	4956 N AGNES AVE	91607	2	168B165    13	2355009065	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.1609	-118.39522	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (64) modules, (2) combiner boxes, and (1) load center.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15110	18041-10000-17359	970 W KNOX ST	90502	15	057B197    24	7351034021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Issued	05/11/2018 12:00:00 AM	ADDRESS	33.8541	-118.29187	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15111	12041-20000-09858	21809 W VENTURA BLVD	91367	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	PIN	34.16926375	-118.60275102	Change of use from retail to take out restaurant.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-09860	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15112	13041-10000-05661	2710 E MEDIA CENTER DR	90039	1	150B213  3658	5442032006	[Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.00	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	PIN	34.10636393	-118.24150489	PLAN CHECK FOR CONDUIT RUNS AND CONNECTION EQUIPMENT. ADDITION OF NEW POWER BOX AND 800A DISCONNECT FOR MOBILE STANDY GENERATOR CONNECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15113	14041-20000-17538	3430 S VERMONT AVE	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.02479	-118.29132	Plan check for power and energy. Preparation for installation of new modular trailers (DOH-approved). 6,918 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15114	18041-20000-21197	9910 N BARTEE AVE	91331	6	201B157   115	2645006043	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Expired	06/09/2024 12:00:00 AM	ADDRESS	34.25051	-118.43188	PV1.  Install 8.125 kW DC roof mounted grid tied PV system and 13.5 kWh energy storage system.  (25) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15115	19041-10000-42073	4650 W SUNSET BLVD 1st Flr	90027	13	147B197   720	5542016030	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.09787	-118.29063	Energy plan check for a T.I. Scope includes new lighting and equipment with a total lighting area of 2,524-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15116	16041-10000-41380	12412 W VICTORY BLVD	91606	2	180B165   732	2333007035	[Q]CR-1VL, [Q]P-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.18651	-118.40363	REMOVE HID FIXTURE AND REPLACE WITH NEW LED FIXTURE. TITLE 24 ONLY. SQFT=60800.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15117	11041-10000-20355	2703 W MARTIN LUTHER KING, JR BLVD	90008	10	114B189   287	5034009052	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			Verifications in Progress	03/02/2012 12:00:00 AM	ADDRESS	34.01095	-118.32246	New 800A service, exist. bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15118	17041-20001-07771	700 S NEW HAMPSHIRE AVE	90005	10	132B197   232	5094011018	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.05951	-118.29274	expedite.pv2install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15119	16041-20001-37153	21021 W VENTURA BLVD ste 200-210	91364	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	11/04/2016 12:00:00 AM	ADDRESS	34.16688	-118.59113	11/04/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plans. All changes have been reflected onto the Title 24 forms. All changes marked as Delta 1.*****Previous Work Description*****ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy and em power only.  total square footage 8852.  scope in suite 200 and 210	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15120	18041-10000-26248	5862 W DAVID AVE	90034	10	123B173   352	5065020014	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2702.00	Electrical	Electrical	Apartment			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.03508	-118.37259	INSTALLATION OF NEW FIREALARM SYSTEM. 1 FACP AND 34 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15121	19041-10000-39341	16221 S MENLO AVE	90247	15	069B197   303	6120017035	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	33.88379	-118.28939	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 5KWac/6.270KWdc. SCOPE OF WORK IS 22 MODULES (HANWHA Q-CELL 285 W) WITH OPTIMZERS (SE P320) LEADING TO A CNETRAL INVERTER (SE5000H-US). PANEL UPGRADE PULLED SEPARATELY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15122	14041-20000-33068	17351 W TENNYSON PL	91344	12	222B129   140	2602012009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.30375	-118.51226	pv1install roof mounted pv system sized 3.0kw interconnected with msp.(12) canadian solar cs6p-235px modules (1) soalr edge se 3000 tl inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15123	14041-20000-20395	9043 N WOODMAN AVE	91402	6	195B153   158	2639033013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.23393	-118.43976	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING ONLY.  COMMERCIAL BUILDING ONE STORY 1874 SQFT.  ALL CIRCUITS ARE EXISTING NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15124	16041-10000-32793	9901 N SUNLAND BLVD	91040	7	201B181    91	2543023018	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.2498	-118.34713	Senate Bill 1221 zero fee. PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.8KWac.(56)MODULES-REC275TP-REC SOLAR(1)INVERTER-(NINGBO TECH.)SOLIS-3.6K-2G-US(1)INVERTER-SOLIS-4.6K-2G-US(1)INVERTER-SOLIS-4.6K-2G-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15125	17041-20002-42588	17130 W CLEMONS DR	91436	5	159B133   154	2292021010	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.1329	-118.5053	02/16/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta C. Changes have been made to the roof layout to comply with LAFD clearance requirements. SLD has been updated accordingly.*****Previous Work Description*****pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15126	15041-20000-35941	442 N SWEETZER AVE	90048	5	141B173  1245	5514004034	R1-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.07945	-118.36988	Plan  check for PV roof mounted system. System size: 3.8kW with 16 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15127	13041-10000-30263	1600 N VERMONT AVE	90027	13	147B197   471	5542014032	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.09994	-118.29154	PLAN CHECK FOR TITLE 24 ENERGY ONLY. CHASE BANK. 587 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15128	17041-20000-31760	977 N NORTH BROADWAY STE 411	90012	1	136-5A215 263	5414007022	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.06611	-118.23652	Plan check for energy only. TI to office suite 411. New lighting (incl. emergency) - 2,222sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15129	19041-30000-35824	4765 W ADAMS BLVD	90016	10	123B181   952	5057003002	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Closed	12/10/2019 12:00:00 AM	ADDRESS	34.03271	-118.34468	PLAN CHECK FOR T-24 ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING TO AN OFFICE SPACE. TOTAL SQ. FT. 2660.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15130	19041-10000-08040	350 WORLD WAY APM West-Station	90045	11	093B161    71	4117033900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	33.94645	-118.40735	"Design of facility power distribution to APM station including to lighting IT/Communication , HVAC, Transportation Loads, etc. Including 340,178 Sqr Ft of T-24. Part of ""People Mover"" project in CTA WEST."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15131	12041-10000-20494	8500 W BEVERLY BLVD # 779	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			PC Approved	08/29/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	Plan check for T24 Energy for existing D&G retail store unit #779. Emergency lighting existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15132	13041-10006-26817	5900 W CENTER DR	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			03/29/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	33.97559	-118.38853	03/26/16Changes to an approved set of plans, note changes on delta 13. Changes include switchgear names and panel names per DWP phasing. No new load or equipment. (((New 327-unit apartment building at Howard Hughes Center.  Power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15133	17041-10000-23604	3361 N ANDRITA ST LOT 2	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 2 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05784	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15134	15041-10001-38109	518 E COMMERCIAL ST guard bth	90012	14	130-5A215  71	5173002901	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05288	-118.23427	PC only due to lost approved set.This is 2 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************One-story pre-fab Guard Booth	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15135	10041-20000-01284	5477 N NESTLE AVE	91356	3	174B125   498	2160018***	R3-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Apartment			01/25/2010 12:00:00 AM	01/25/2010 12:00:00 AM		Permit Finaled	04/06/2010 12:00:00 AM	ADDRESS	34.1703	-118.5299	Replacing 800 amps service/pull box and replacing (6)  125 amp meters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15136	19041-20000-25586	601 S FIGUEROA ST STE 2150	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	T24 PLAN CHECK ONLY FOR TI TO A EXISTING HIGH RISE COMMERCIAL BUILDING SUITE 2150 OFFICE ROOM. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 302SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15137	14041-10001-03068	10326 W WALAVISTA ROAD	90064	5	123B161   749	4318033003	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			Reviewed by Supervisor	02/10/2014 12:00:00 AM	ADDRESS	34.032	-118.41211	Expedited RSES plan check per applicant request.{[PV1, Install 5.5 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(22) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15138	17041-20000-00117	21434 W SHERMAN WAY	91303	3	183B105   179	2111028001	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.20085	-118.59883	ti to an existing commercial building.  adding new lighitng new controls to new panels.  newly connectred load < 400 amps.  plan check for energy and em lighitng only.  total square footage 1394.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15139	12041-10000-26582	11920 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Approved	11/06/2012 12:00:00 AM	ADDRESS	34.05237	-118.47062	TI for a GYM. EPC for T24 and emergency lights. (B occupancy)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15140	11041-20000-17216	8221 S WESTLAWN AVE	90045	11	099B161   999	4112026012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	33.96377	-118.40795	PLAN CHECK FOR 2.82KW ENPHASE MICROINVERTER SYSTEM FOR SINGLE FAMILY DWELLING. VARIANCE FOR PRIOR TESTING LAB APPROVAL HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15141	19041-20000-24371	500 WORLD WAY I Love-L.A.	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	new LED sign.  plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15142	19041-10000-05580	9851 S ALAMEDA ST	90002	15	093A217   270	6046019***		South Los Angeles	SOUTHEAST LOS ANGEELS			2421.00	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	33.94801	-118.22929	PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT TO EXISTING SPACE FOR A NEW DENTAL CLINIC 3,358 SQ FTCHANGE OF USE MERCANTILE TO MEDICAL CLINIC -	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15143	17041-20000-34100	7330 N FIGUEROA ST	90041	14	162A231   184	5709006005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.13696	-118.1878	Plan check for a fire alarm system for a school. Fire alarm consists of (1) FACP and (49) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15144	16041-10000-25859	11617 W DEHOUGNE ST	91605	2	183B169   330	2320008021	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.1964	-118.38484	Plan check for T-24 only on (E) commercial building. remove HID fixtures and replace with new LED fixtures,. Total affected area; 12,928 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15145	13041-10000-33092	5612 N FIGUEROA ST	90042	1	151-5A229 328	5468032014	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.10907	-118.19349	TI for a yoga studio in a single-story commercial building.  Newly connected load does not exceed 400A - Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15146	19041-10000-29214	568 N GOWER ST	90004	4	141B189   769	5523027005	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	09/14/2019 12:00:00 AM	ADDRESS	34.08093	-118.32258	NEW PV1 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER SYSTEM. (22) MODULES (22) OPTIMIZERS AND (1) 6KW INVERTER. TOTAL SYSTEM SIZE IS 6KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15147	18041-10000-32915	4460 W WILSHIRE BLVD	90010	4	132B189    45	5090019***	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			08/28/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Issued	09/05/2018 12:00:00 AM	ADDRESS	34.06172	-118.32623	Energy plan check for the lobby area located in the apartment building with new lighting and equipment. Total area is 2026-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15148	16041-20000-11375	3851 N RANDOLPH AVE	90032	14	145-5A233 226	5306010053	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	04/09/2016 12:00:00 AM	PIN	34.0919151	-118.17990927	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15149	16041-20001-27487	10337 N LARAMIE AVE	91311	12	204B113   107	2707023008	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.25841	-118.57297	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 12.0kW with 55 modules and 2 inverters(60.kW) connected to MSP.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15150	14041-10001-31742	819 N LA BREA AVE	90046	5	141B181   189	5525004008	C4-1VL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	PIN	34.08582658	-118.34439144	Changes to an approved set of plans. Changes are only to lighting. All changes have been reflected on the Title 24 compliance forms.*****Previous Work Description*****Plan check for Title 24. Total lighting area (indoor and outdoor) = 8,488 sq. ft. Project is a tenant improvement to an existing commercial space (retail).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15151	17041-20001-31665	10430 N SEPULVEDA BLVD	91345	7	207B145   770	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.26014	-118.46701	06-21-2018 Changes to an approved set of plan, changes include relocate load from MSF to MPD 600A switch gear. All Changes has been clouded under delta A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15152	18041-20001-01359	555 S FLOWER ST 33rd  FL	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.05048	-118.25755	Revision to approved set.  Changes to lighting fixture schedule and lighting plan layout.  Review of clouded revisions delta-1, 0, and A. (((TENANT IMPROVEMENT FOR ENTIRE 33RD FLOOR.  PLANCHECK FOR POWER AND ENERGY. BUILDING PERMIT #  18016-10000-00324)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15153	19041-20000-37109	531 N CHAPALA DR	90272	11	126B129   791	4411011043	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.03846	-118.52123	Plan check for PV roof mounted system, PV system size: 7.2KW DC, 6.519KW AC CEC with 20 PV Modules and 20 microinverters connected to existing 600A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15154	17041-10000-04996	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.24138	-118.60168	OFFICE AND FACTORY AREA TI. NEW MACHINES AND EQUIPMENT. PC FOR POWER AND ENERGY. NEW CONNECTED LOADS GREATER THAN 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15155	12041-10000-29766	2970 W OLYMPIC BLVD SUITE 201	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	12/11/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT FOR NEW OFFICE IN EXISTING MEDICAL OFFICE BUILDING. THREE STORY BUILDING. SCOPE OF WORK IS 784 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15156	18041-10000-41204	18300 W EDDY ST	91325	12	195B125  1040	2786003038	M1-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.22733	-118.53165	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15157	11041-10000-18193	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	TI TO AN EXISTING OFFICE SPACE.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15158	14041-20001-21348	6201 W HOLLYWOOD BLVD 114	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	Energy plan check for TI from retail to an exercise Gym, suit number 114 from a commercial building. total area is 3714SQ feet. change  all lighting design	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15159	15041-10002-38296	5437 N LUBAO AVE	91364	3	174B113   541	2164003017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.16938	-118.56707	2/23/16: Revision to approved set: revised the orientation of the rooftop modules (strings), total number of modules remain to be 73 modules. $0 fee due to State Senate Bill SB-1222. <<<PV1, 18.98 kW system, roof mounted solar array.  (73)modules: Canadian Solar CS6P-260P   (2)inverters: FRONIUS   PRIMO 8.2-1>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15160	18041-10001-08932	9764 N NATICK AVE	91343	7	201B149   385	2650016004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM			PC Approved	07/10/2018 12:00:00 AM	ADDRESS	34.24767	-118.45286	VOID SUPP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15161	15041-10000-18747	12452 W OSPREY LANE	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'B'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'B' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15162	12041-10000-21793	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM			PC Info Complete	09/25/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	(#A1-107)  TENANT IMPROVEMENT, W LIGHTING, DUCT WORK, MECHANICAL UNITS;  NO CHANGE IN OCCUPANCYPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15163	16041-10000-40689	700 W 7TH ST Plaza Lvl	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	Alteration to (E) restroom. new lighting. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15164	14041-20000-24191	5842 N COSTELLO AVE	91401	2	174B153   122	2246014002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM			PC Approved	09/04/2014 12:00:00 AM	ADDRESS	34.17697	-118.43765	Plan check only, for change of size of solar breaker in main service panel from 35A to 40A only. Permit issued under permit #13041-10000-35300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15165	18041-30001-21148	1767 S WESTWOOD BLVD	90024	5	129B153   409	4324028046	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.05063	-118.43798	PC FOR T-24  ENERGY ONLY FOR RESTAURANT OUTDOOR LIGHTS IN PATIO( 2 FIXTURES). TOTAL AFFECTED AREA 500 SQ.FT.THIS IS PLAN CHECK ONLY. PERMIT PAID UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15166	14041-10001-05681	4251 S CHASE AVE	90066	11	108B157   623	4231009025	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	33.99289	-118.4297	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(14) MODULES: CANADIAN SOLAR CS6P-250PX(1) SOLAREDGE SE3800A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15167	19041-10000-49191	737 S CROCKER ST	90021	14	126A213   344	5146033054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Info Complete	12/05/2019 12:00:00 AM	ADDRESS	34.03936	-118.24691	TITLE 24 PLAN CHECK FOR A TI. SCOPE OF WORK INCLUDES REPLACEMENT OF DAMAGED LIGHTING DUE TO FIRE. TOTAL AFFECTED AREA: 8,725 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15168	12041-10000-17926	11818 W TERRA BELLA ST	91342	7	213B169   696	2530027002	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.04	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.27865	-118.39019	Plan check for PV system. Single family dwelling. 7.848 kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15169	13041-10000-20954	19934 W ENADIA WAY	91306	3	183B113   146	2135010029	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.19991	-118.56807	PV1 6.86KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: powerone PVI-6000-OUTD-US] [( 28) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15170	15041-20000-28090	9132 N DE GARMO AVE	91352	6	198B173   154	2408034047	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Closed	02/14/2022 12:00:00 AM	ADDRESS	34.23512	-118.3746	Title 24 plan check only.  Total area = 91,560 sq. ft.  Addition of 200 A service for six parking lot lights + water pump, compressor, and truck scales.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15171	16041-20000-10560	6053 W CENTURY BLVD Ste 900	90045	11	093B169   305	4124030902	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	33.94648	-118.38998	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 592 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15172	16041-10000-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT. BUI;DING APPLICATION 16010-10000-04147	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15173	16041-20000-39753	5122 N TUJUNGA AVE	91601	2	171B173   815	2353002022	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.16357	-118.37881	Plan check for power only. Project site is an existing commercial building. Project scope is a new 800-amp service and new distribution equipment. All load is existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15174	15041-20001-38096	8552 N OUTLAND VIEW DR	91352	2	192B177   175	2404028007	RE15-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.22452	-118.35778	EXPEDITE PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.7KWdc/10.0KWac. (45) MODULES-CANADIAN SOLAR CS6P-260P(2)INVERTERS-FRONIUS PRIMO 5.0(1)SUBPANEL-100A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15175	15041-20002-14903	14518 W VENTURA BLVD	91403	4	166-5A151 139	2276001004	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	ADDRESS	34.15087	-118.4494	10-20-2015 Plan Check for Title 24 only. Total area: 1,249 sqft. Change to an Engineer on record. *************************************((7/2/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2.  CHANGES INCLUDE ADDITION OF LIGHT FIXTURES AND REVISIONS TO ENERGY CALCULATIONS. MASTER PERMIT HAS NOT BEEN PULLED 15041-10000-14903, DO NOT ISSUE THIS SUPPLEMENTAL PERMIT UNTIL MASTER IS PULLED. Engery plan check for a retail to restaurant building (Presseat). Scope includes new lighting, equipment and receptacle outlet.**RELOCATE METER.*****************************************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15176	19041-20000-29198	7362 N BOTHWELL ROAD	91335	3	186B117   626	2116003040	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.20459	-118.56079	PV1.  Install 8.19 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (26) modules with 7.6 kW rated inverter.Fee $89.43 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15177	10041-10000-23721	2036 S ROBERTSON BLVD	90034	10	126B169   704	4302018006	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM			PC Info Complete	03/11/2011 12:00:00 AM	ADDRESS	34.04128	-118.38735	NEW MECHANIC SHOP. PLAN CHECK IS FOR POWER & ENERGY.  (T-24 CALCS MISSING).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15178	11041-10002-22612	175 S FAIRFAX AVE	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	DELTA 3 CHANGES TO APPROVED PLANS.  RELOCATING 1200AMP PANELS TO REDUCE THE S.C. RATING FROM 100KAIC TO 65KAIC, ADD NEW CIRCUITA & LIGHTS. PLAN CHECK FOR POWER & ENERGY 16,500 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15179	18041-10000-23714	900 W WILSHIRE BLVD 19TH FLR	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR AN OFFICE SPACE ON THE 19TH FLOOR OF AN EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 21,000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15180	16041-20001-43904	9653 N AMESTOY AVE	91325	12	201B133   455	2692017009	RA-1-H	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/18/2016 12:00:00 AM	ADDRESS	34.24627	-118.50694	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15181	14041-10000-00894	721 E 12TH ST #2	90021	14	124-5A211 307	5132012106	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.03348	-118.25258	Ti in an existing retail. T24 only. replacing 3 fixtures. all ckts & emergency are existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15182	17041-20001-43986	23159 W BIGLER ST	91364	3	171B093   807	2074021017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	34.16076	-118.63125	Expedited plan check fee. PV1.  Install 10.2 kW roof mounted grid tied PV system.  (34) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15183	12041-10000-30780	12751 W MILLENNIUM GARAGE	90094		102B161  1175	4211033020							Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	PLAN CHECK POWER AND ENERGY FOR COMMON SUBTERRANEAN PARKING GARAGE FOR BUILDING A AND BUILDING B. SITE LOCATED IN METHANE ZONE. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15184	17041-10001-02816	8229 N WOODMAN AVE	91402	6	192B153   835	2213016021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.22031	-118.43267	Changes to an approved set of plans. All changes are clouded under delta 2. Changes include revising single line diagram to reflect as built, and revising panel schedules. PC for disaggregation of electrical loads. Note: Permit is paid under PCIS#18041-90000-06771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15185	18041-20000-21731	616 N ALVARADO ST	90026	13	138A207   112	5404011026	CM-1VL, CR-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.20	Electrical	Electrical	Apartment			06/12/2018 12:00:00 AM			Reviewed by Supervisor	08/02/2018 12:00:00 AM	ADDRESS	34.07332	-118.26589	New 6-story 12-unit mixed-use apartment building.  1000A 208Y/120V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15186	11041-10000-20297	624-630 N NORTH MAIN ST	90012	14	132A215    40	5408011907	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.05761	-118.23822	title 24 and emergency lighting. space incloud 624-630 n north main , LA GOLONDRINA RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15187	17041-20000-15786	928 S CONCORD ST	90023	14	121-5A225  87	5188023005	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.0278	-118.20331	Plan check for pv solar system, roof-mounted on SFD.2.88kW ungrounded system. (12) EnPhase M250-72 microinverters.(12) 340W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15188	18041-10000-24020	10250 W SANTA MONICA BLVD #2885	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for first time tenant retail space #1520 at Century City Mall. Total area: 2,880 sq.ft. Install (3) new panelboards, (1) 30kVA transformer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15189	15041-10000-42820	701 W EXPOSITION BLVD	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.01842	-118.2857	PC FOR POWER AND ENERGY. 8-STORY BUILDING IN USC CAMPUS. (BUSINESS SCHOOL). T.I FOR BASEMENT THROUGH 4TH FLOOR. ADDITION OF NEW LOADS TO EXISTING PANELS. TOTAL AREA 23439 SQ FT. (FULL PC PAER APPLICANT REQUEST)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15190	15041-20000-16532	6430 W SUNSET BLVD 704-707	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.09782	-118.32979	plancheck for t24 energy.  Tenant improvement work for offices. suite 704/707. 2375 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15191	14041-20000-06526	11743 W GOSHEN AVE	90049	11	129B145   569	4265010016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.04953	-118.46283	13 UNITS APARTMENT BUILDING FIRE ALARM VARIANCE ON FILE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15192	11041-20001-04675	623 S LINCOLN BLVD	90291	11	111B145   846	4240016054	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			PC Approved	06/08/2011 12:00:00 AM	ADDRESS	33.99971	-118.46485	Modification to existing set of approved plans.  Mdification was done to the emergency lights and to the lighting fixtures.  Plan check is for Energy only.  <<<<<<<PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT TI IN 1 STORY BUILDING. NEW 400A SERVICE. INSTALLATION LESS THAN 400A LOAD.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15193	12041-20002-31078	18211 W VENTURA BLVD	91356	3	171B125   273	2160014010	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.16621	-118.52912	((9/17/2013- CHANGES MADE TO APPROVED T24. DISPLAYING INRACK LIGHTS ON LIGHTING PLANS AND ACCOUNTED FOR ON TITLE24 LTG FORMS. FIXUTRE COUNTS DID NOT CHANGE FROM 12041-10001-31078.))Plan check for energy and emergency lighting. Stand alone building. Office Depot. 7460 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15194	19041-10000-05810	11611 W SAN VICENTE BLVD UNIT 700	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.0541	-118.46261	PLAN CHECK FOR ENERGY ONLY. OFFICE T.I. SCOPE OF WORK INCLUDES NEW LIGHTING IN CONFERENCE AREA. TOTAL OF - 1958 SF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15195	17041-10003-39640	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	08/23/2021 12:00:00 AM	ADDRESS	33.94571	-118.38857	Changes to an approved set of plans. All changes are cloudeded under delta 8. Changes include adding an 150KVA transformer, new panels, and relocating loads on the single line diagram, and relocating panels to roof-top. B#16016-10000-29872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15196	18041-10000-09583	15392 W COBALT ST	91342	7	222B145     5	2501006027	M1-1, M2-1, P-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.30943	-118.46701	REMOVE INDOOR-OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15197	14041-10000-33750	5248 N SHEARIN AVE	90041	14	163-5A223 114	5669028024	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.14235	-118.21022	Installation of a PV1 roof-mounted PV system. System consists of (1) inverter, (1) combiner box, and (27) modules. System size is 6 kWac. FEE AMOUNT REFLECT ON SENATE 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15198	08041-10001-09518	2319 N DORRIS PL	90031	13	144B213   205	5445005***	[Q]PF-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM			PC Approved	01/20/2010 12:00:00 AM	ADDRESS	34.09165	-118.23683	1-20-10 - Supplement is for inspector request for plans to reflect as-built.  P/C is for Power only ::  Remove and replacement in the Standard and Testing Loboratory Building of hoods, exhaust fans, packaged rooftop, units including ductwork, piping and accessories.  Installing new energy management system.  P/C for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15199	15041-10000-04736	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Expired	03/21/2017 12:00:00 AM	PIN	33.93847109	-118.41935625	Installation of 3000A swbd/service only. Future use is for the new service to supply power to future loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15200	15041-10000-18299	1016 N COLE AVE	90038	13	144B185   888	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.08942	-118.32972	NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15201	19041-10000-39011	14198 W ALISAL LANE	90402	11	126B133   203	4408029025	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.03976	-118.51033	[Eplan] plan check for 2 New Energy Storage Systems(Tesla Powerwall) @27KWH, & 1 New 125A Load Center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15202	19041-10000-50185	1749 N HARVARD BLVD	90027	13	148-5A195 555	5544008012	R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.10308	-118.30517	[EPLAN] NEW PV1 ROOF MOUNTED INSTALLATION WITH SYSTEM SIZE OF 12.6KW DC/ 11.4 AC, 36 MODULES (LG350N1C), 1 CENTRAL SOLAREDGE INVERTER (SE11400-US), 36 POWER OPTIMIZERS (P370) AND CONNECTED TO NEW MAIN SERVICE PANEL RATED AT 225A. Fees $42.35 due to California Senate Bill 1222 and AB1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15203	13041-10000-35481	445 S FIGUEROA ST 14TH FLR	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	14TH FLOOR TENANT IMPROVEMENT IN HIGH-RISE BUILDING.  LIGHTING WORK IS APPROX. 14,071 SQ FT, UTILIZING TAILOR COMPLIANCE METHOD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15204	11041-10000-04122	1420 W FRANCISCO ST	90501	15	057B197   120	7351037018	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	33.85005	-118.30021	TENANT IMPROVEMENT BUILD OUT OF EXISTING SHELL MEZZANINE. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15205	16041-10001-00016	7224 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			PC Info Complete	02/23/2016 12:00:00 AM	ADDRESS	33.97406	-118.2913	2/23/16: Chages to approved set on Delta-2 and Delta-3: Relocate FACP to the Liquor store, added 21 devices. <<New fire alarm system in existing grocery store.  Total system size = 44 devices + 1 FACP>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15206	12041-20000-27957	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Approved	11/26/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	Change to lighting to an existing retail space at the grove.  NOT a Place of Assembly per applicant and no new load.  Site is located in a METHANE Zone, no penetration of methane membrane per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15207	16041-20000-15635	7655 N MASON AVE	91306	3	186B109    38	2108024001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Expired	06/06/2018 12:00:00 AM	ADDRESS	34.20992	-118.57992	Plan check for a PV1 roof-mounted PV system. System size is 7.2 kWac and consists of (2) inverters, (35) modules, (1) combiner box, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15208	14041-10002-01961	14620 W SUTTON ST	91403	4	165A149    87	2276028039	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1413.04	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.14755	-118.45313	changes to approved: addition of 2 new modules. PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(18)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15209	13041-10000-30908	18815 W CELTIC ST	91326	12	210B121   669	2717022022	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.26884	-118.54336	PV1, Install 3.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15210	15041-20000-39598	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.20103	-118.38536	"Plan check for power only.  Replace existing distribution panel ""PDS"" with new panel. Replace three existing  125 KVA UPS with two 125 kVA UPS systems."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15211	10041-20000-20455	10118 N SAN FERNANDO ROAD	91331	7	204B161   473	2537010002	[Q]CM-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.25423	-118.40867	New building with 8 units.  New 800A service, panel boards, branch circuits.  Install outdoor lighting in the parking lot.  Plan check for core and shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15212	18041-10001-26329	3150-3158 W OLYMPIC BLVD	90006	10	129B193   327	5080022016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.05238	-118.30484	PLAN CHECK ONLY UNDER DELTA 2 CHANGES. SCOPE OF WORK INCLUDES CHANGE OF FEEDERS AND OCPDS. ____________________________________________CONVERT ONE RETAIL SPACE INTO 4 RETAIL SPACES.  NEW 600 AMP SERVICE, PANEL & LOADS.PLAN CHECK FOR POWER & ENERGY.BUILDING PERMIT: 17016-10000-13685	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15213	12041-20000-26090	10880 W WILSHIRE BLVD 2222	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.05885	-118.44283	Change to lighting on the 22nd floor in the restroom.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15214	13041-20000-20166	8525 N WHITE OAK AVE	91325	12	192B129    96	2787012001	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Expired	08/24/2015 12:00:00 AM	ADDRESS	34.22528	-118.52029	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE: 8.575KW. 35 PANELS AND 2 INVERTERS WITH 1 SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15215	10041-10000-09818	6100 W CENTER DR #1000	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM			PC Approved	05/24/2010 12:00:00 AM	ADDRESS	33.97733	-118.3922	T-24 and emergency lighting on the 10th floor. Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15216	18041-10000-20425	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.09822	-118.31812	PC FOR NEW FIRE ALARM FOR 15 FLOOR AND 2 BASEMENTS COMMERCIAL OFFICE AND RETAIL. SCOPE INCLUDES 1 FACP, 25 RPS, 5 PANELS AND 971 DEVICES. PLAN CHECKER TO VERIFY COUNT. B# 16010-10000-04681	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15217	14041-20000-31514	6255 W SUNSET BLVD Suite 820	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for energy only. TI to existing office on 8th floor of existing high rise office building. New receptacles and lighiting (including emergency). 1,649sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15218	14041-20000-18920	7533 N MELBA AVE	91304	12	186B093   228	2027031055	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.20692	-118.63396	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MAIN SERVICE PANEL.(21) SOLAR WORLD SW275M PANELS(1) PVI TRANSFORMERLESS INVERTER 5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15219	13041-20000-35513	20111 W ELKWOOD ST	91306	3	189B113   956	2107023064	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.21252	-118.57148	PV1 STANDARD PLAN. TOTAL SYSTEM SIZE 7.5 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15220	16041-10000-04209	2154 S WESTWOOD BLVD	90025	5	126B157   192	4321012031	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	11/29/2023 12:00:00 AM	ADDRESS	34.04457	-118.43205	Full Plan Check, New 3 story building. Basement is used for retail, second and third floor is for office use. All electrical equpment is new.  Total sq ft =4664	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15221	18041-10000-43928	6901 S LA TIJERA BLVD	90045	11	102B173   140	4103003026	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	33.97623	-118.37337	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15222	17041-10000-30523												Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15223	17041-10001-24243	2349 S CLOVERDALE AVE	90016	10	123B177   403	5063008055	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.03551	-118.35629	change to approved set of plans. change to point of interconnection. interconnection at unit subpanel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15224	19041-20000-09552	3900 W JEFFERSON BLVD	90016	10	120B185   890	5046004902	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	11/16/2020 12:00:00 AM		Issued	11/16/2020 12:00:00 AM	ADDRESS	34.02544	-118.33866	FULL PLAN CHECK FOR NEW 2500A SERVICE WITH PANELS, AND LIGHTING AND POWER LOADS. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 65,353 SFBuilding permit submitted under 19010-20000-01124, per building permit[New 3-story mixed use commercial building core and shell.  2500A 208Y/120V 3ph-4w service.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15225	18041-10000-39953	5575 W WILSHIRE BLVD	90036	4	135B181   892	5508012025	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.06251	-118.35008	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15226	19041-20000-00697	2328 W 37TH ST	90732	15	009B189    61	7563031025	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Expired	10/10/2023 12:00:00 AM	ADDRESS	33.72337	-118.3261	Plan check for a PV1 roof-mounted PV system. System size is 13.12 kWdc/10.98 kWac-CEC and consists of (2) inverters, (36) modules, (1) auto-transformer, (1) load center, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15227	11041-20000-27651	4391 N VANALDEN AVE	91356	3	165B117   184	2178021039	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.14979	-118.55613	New 8.64 KW roof mounted system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15228	14041-10000-31541	4640 N LANKERSHIM BLVD	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.15499	-118.36841	Replacement of fire alarm panel and new monitor modules/relay modules.  Existing fire alarm system notification and initiating devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15229	18041-20000-01530	19466 W ROSITA ST	91356	3	168B117   310	2178013038	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.15672	-118.55819	permit fee $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 14.5kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15230	12041-20000-25302	7523 N SYLVIA AVE	91335	3	186B117   336	2104018042	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.2071	-118.55257	Change of contractor with new design. Original was on 12041-20000-20999. Zoning clearance obtained on this application.Previous agreement to do plan check over the counter instead of backroom.Plan check for PV system. Single family dwelling. 4.32 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15231	15041-10004-12226			14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	PIN	34.04915052	-118.25894298	"PC FOR LOST SET OF PLANS. THIS IS ""PLAN CHECK ONLY""! PERMIT PULLED UNDER MASTER PERMIT. 11/9/2017 SCOPE REMAIN THE SAME AS BELOW:TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW AND EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2800.  SCOPE OF WORK TO BE PERFORMED IN FLOORS 2,9,10,12 PLUS PENTHOUSE ONLY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15232	17041-10002-14333	8900 W VENICE BLVD	90232	5	120B169   508	4312014271	(T)(Q)M1-2D	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM			PC Approved	04/08/2019 12:00:00 AM	ADDRESS	34.02908	-118.38822	"Changes to an approved set of plan. All changes are clouded under delta ""ASI #12C"". Changes include removing lighting fixtures and receptacles from future tenant spaces. Revising panel schedules due to reduction in loads.Note: Permit has been paid under PCIS#17041-10000-14333. Plan check Only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15233	16041-20000-24744	1901 S SEPULVEDA BLVD	90025	5	126B153   287	4323025039	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.04414	-118.44168	PLANCHECK FOR POWER AND ENERGY. CHG OF USE FROM RETAIL TO SELF STORAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15234	17041-10000-24267	2351 S CLOVERDALE AVE	90016	10	123B177   403	5063008055	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.03544	-118.35632	PC FOR PV SYSTEM 3.8KW AC USING CENTRAL INVERTER AND 9 MODULES WITH POWER OPTIMIZERS. zoning clearance covered under 2349 cloverdale	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15235	14041-10001-08922	14756 W ARCHWOOD ST	91405	6	180B149   153	2236003015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	34.19275	-118.45502	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(20) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15236	13041-10000-06542	6900 W BONITA TER	90068	4	150B181   562	5549017006	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/13/2013 12:00:00 AM			Plans on Hold	03/14/2013 12:00:00 AM	ADDRESS	34.10467	-118.34034	"ON 'HOLD'.  APPLICANT WILL REQUEST FOR REFUND AND WILL RESUBMIT THE PLAN WITHOUT THE ""FO"" FEES.  ===>  RESUBMITTED UNDER PCIS # 13041-10000-06804  ON  3/15/2013  <<<NEW 4 STORY, 16 UNIT APARTMENT BUILDING.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15237	14041-10000-25801	1232 S LA CIENEGA BLVD # 101,102	90035	5	132B173  1104	5087003006	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.05473	-118.37596	PC FOR ENERGY ONLY TENANT IMPROVEMENT FOR SUITE #203.  TOTAL AREA 2163 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15238	13041-10000-29164	12555 W JEFFERSON BLVD 2ND FLR.	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	33.97954	-118.41361	Two story office building, second floor ti and emergency lighting.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15239	16041-20000-16874	10626 S GORMAN AVE	90002	15	090A217   506	6066014065	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	33.93899	-118.23058	Plan check for PV roof mounted system. System size: 8.7kW with 35 modules and 35 microinverters Enphase.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15240	13041-10001-22274	23625 W STRATHERN ST	91304	12	189B093   259	2020018050	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.21519	-118.64164	EXPEDITED PLAN CHECK PER APPLICANT REQUEST.  (((PV1.  INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15241	10041-20001-17858	13643 W VAN NUYS BLVD	91331	7	207B157  1139	2618023002	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.02	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	12/02/2010 12:00:00 AM	ADDRESS	34.26048	-118.43017	SUPPLEMENTAL APPLICATION FOR PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR MARKET TI. ADDITIONAL PERMIT FOR CKTS AND EQUIPMENT NOT COVERED ON PREVIOUS PERMIT .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15242	14041-20000-19056	8460 N SAN FERNANDO ROAD	91352	6	192B173   259	2632027030	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.22387	-118.37501	Plan check for power only. Existing industrial stone fabrication facility, upgrade of main service to 1600A. Existing loads to be installed on new 1600A distribution panel.  New transformers, some new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15243	16041-10000-14144	8032 S DUNBARTON AVE	90045	11	099B161   571	4109032014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	33.96605	-118.40726	SOLAR SYSTEM 5.5KW-SFD, 21 MODULES AND OPTIMIZERS WITH SOLAREDGE 5.0KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15244	17041-30000-28234	7270 WORLD WAY WEST Fence-Lighting	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	01/20/2022 12:00:00 AM	ADDRESS	33.94145	-118.42037	Plan Check for AOA fence lighting, add new transformer and panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15245	15041-20000-24734	13083 W PINNEY ST	91331	7	210B161   548	2534014010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.27062	-118.41805	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (24) modules, (24) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15246	18041-10000-44272	2600 S VERMONT AVE	90007	8	123B197   900	5055005033	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.03252	-118.29135	plancheck for power and energy. new modification to deli/bakary prep inside ralphs store. area of scope is 30441 sq-ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15247	19041-10000-32981	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	33.78808	-118.29535	CHANGES TO APPROVED SET OF PLANS - CHANGES ARE CLUODED UNDER DELTA #3 - CHANGES INCLUDE ADDITION OF 2000 KVA TRANSFORMER AND ASSOCIATED WIRING  ORIGINAL PERMIT PLAN CHECK FOR POWER FOR NEW - Installation of foundation for fuel cell generator with concrete pads. - TOTAL NEW CONNECTED POWER = 2162KVA SYSTEM	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15248	13041-10000-20896	23045 W CALIFA ST	91367	3	177B097   579	2041021003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.17749	-118.62907	PV1.  Install a 7.37 kW AC roof-mounted solar array, interconnect into main service panel.  {Central inverter: SMA Sunny Boy SB8000US} {33 modules: Aleo Panel S_79 260W}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15249	13041-20000-03837	120 S GRANVILLE AVE	90049	11	135B145   691	4401002010	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			02/13/2013 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.06333	-118.47138	Full plan check for new 32 unit apartment. NOT a methane zone. Plan check fees per applicant, please verify during final pay period. Fire Alarm Variance has been filed.Variance to extend plan check time filed 07/01/2014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15250	12041-10000-04488	14800 S FIGUEROA ST 1st fl	90248	15	075B201   141	6129001046	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	33.89809	-118.28288	TENANT IMPROVEMENT TO 1ST FLOOR OFFICE AREA AND RESTROOM.plan chk is for title 24.  Permit fees are under inspection.  Panels are 'for future' with no circuits.  Load is 67Amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15251	19041-10000-21112	22008 W GRESHAM ST	91304	12	195B101   217	2010008004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.23013	-118.60616	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM IS 12.96KWdc / 11.4KWac.(36)MODULES- POWERXT-360R-PD (36)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE11400H-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15252	17041-20000-03787	14347 W BURTON ST	91402	6	192B149   438	2212004018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.22074	-118.44626	pv1addition to an existing pv system.  install roof mounted pv system sized 3kw interconnected wtih msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15253	16041-10000-13961	1511-1513 S MANHATTAN PL	90019	10	126B193    70	5073009002	R2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.04498	-118.31036	PC FOR POWER ONLY. CHANGE FROM A SINGLE FAMILY HOME INTO A DUPLEX. SCOPE INCLUDES A NEW 600A 120/240V 1 PHASE 4 WIRE SERVICE,  AND NEW SUBPANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15254	19041-20000-41043	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15255	15041-20000-02598	15207 W SUNSET BLVD	90272	11	129B129   809	4423016073	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	02/03/2015 12:00:00 AM	ADDRESS	34.04647	-118.52446	TI TO PHYSICAL THERAPY. PER APPLICANT NO POWER. NEW LIGHITNG ONLY. PC FOR T24 ENERGY ONLY. NEW LIGHTING AND CONTROLS.permit issued from an online application, 15041-90000-00443	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15256	18041-10000-16603	465 S LA CIENEGA BLVD	90048	5	135B173   130	4334019064	(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.06979	-118.37662	PC FOR TITLE 24 FOR NEW SIGN LIGHT.SCOPE INCLUDES  New externally illuminated vinyl wall sign (17' x 49') WITH 6 FIXTURES.  B# 18048-10000-00656	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15257	16041-20000-43349	19548 W BALLINGER ST	91324	12	198B117    25	2761038009	RE15-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Issued	12/20/2016 12:00:00 AM	ADDRESS	34.24327	-118.55991	PV1.  Install 11.06 kW roof mounted grid tied PV system.  (33) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15258	19041-20000-37398	16702 W TUBA ST	91343	12	204B137   416	2685014021	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.25645	-118.49597	PV1. INSTALL 3.50 KW DC / 3.04 KW AC SOLAR SYSTEM WITH (10) MODULES AND OPTIMIZERS AND (1) INVERTER (SE6000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15259	17041-20000-35194	8527 N SEPULVEDA BLVD	91343	6	192B145   119	2654020015	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.22544	-118.46799	PV2.  CARPORT WITH ROOFTOP SOLAR SYSTEM  + ( roofmount under application # 17041-20000-35189)                                  TOTAL SYSTEM SIZE: 68.950 KW DC TOTAL.17010-20000-03781    building permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15260	15041-10001-34836	5670 W WILSHIRE BLVD 25TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM			PC Info Complete	03/29/2016 12:00:00 AM	ADDRESS	34.06222	-118.35208	"Revision to approved set under Delta-5. (1) Revise location and qty of light fixtures (T-24)(2) Add branch ckts under panel 25XD(3) Relocate panel 25XD from Rm.206 to Rm.205(4) Relocate panel SERV from ""Back room"" to Rm. 204.(5) Relocate panel 25XC from Rm.206 to Rm.205 <<T-24, TI TO THE 25TH FLOOR OF AN (E) HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES WITH EXISTING PANELS. TOTAL SQ. FT. 12854.>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15261	13041-10000-34344	21423 W STRATHERN ST	91304	3	189B105   149	2110020005	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.21566	-118.59862	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For autoshop (NON-HAZARDOUS PER APPLICANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15262	17041-10000-45885	813 1/2 N HARPER AVE	90046	5	141B173   148	5529010027	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.0858	-118.36932	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.7KWdc / 3.8KWac.(10)LG 360Q1C-A5(10)OPTIMIZERS-P370 SOLAREDGE(1)INVERTER-SOLAREDGE 3.8H	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15263	19041-20000-37868	21600 W OXNARD ST STE 1900	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Issued	09/20/2019 12:00:00 AM	ADDRESS	34.179	-118.6002	T24 PLAN CHECK ONLY FOR TI REMODEL OF SUITE 1900 IN EXISTING HIGH RISE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2210 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15264	16041-10000-25918	11836 W VOSE ST	91605	2	183B169   215	2321007008	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Issued	09/23/2016 12:00:00 AM	ADDRESS	34.19833	-118.3911	PC FOR SERVICE UPGRADE. 800A DROP TO 2 SERVICE ENTRANCE. ONE RISER WILL FEED EXISTING PANEL AND OTHER RISER WILL BE FOR THE NEW 600A PULL SECTION.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15265	14041-10005-00855	6417 W SELMA AVE	90028	13	148-5A187 302	5546007022	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.09988	-118.33008	CHANGES TO APPROVED SET OF PLANS. TO MATCH PER CONSTRUCTION. NEW DISCTRIBUTION SECTION AND CHANGE TO LIGHTING. pc only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15266	13041-10000-06781	1010 N HIGHLAND AVE	90038	4	144B185   909	5532027013	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM			PC Approved	03/20/2013 12:00:00 AM	ADDRESS	34.08928	-118.33841	T24 FOR EXISTING OFFICE SPACE AND WAREHOUSE AREA. SQRFT 7476. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15267	13041-10000-23721	15916 W HIGH KNOLL ROAD	91436	5	165B141   407	2285011015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.14663	-118.48018	PV1 10.29KWdc 240V XFMR (neg grounded) INV. 1STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 10-1UNI][( 42) MOD: Trina {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15268	11041-20000-25625	9301 N TAMPA AVE # 79A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	T24 and emergency lighting plan check for remodeled tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15269	13041-10000-19797	1171 W ENGLANDER ST	90731	15	024B193    53	7442007018	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM			Reviewed by Supervisor	08/26/2013 12:00:00 AM	ADDRESS	33.76472	-118.3024	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD USING POWER OPTIMIZERS (TRANSFORMERLESS).[ MODULES: SUNMODULE # SW 260 |||| INVERTER: SOLAREDGE # SE3000A-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15270	19041-10000-39280	1901 S AVENUE OF THE STARS Ste.920	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.05949	-118.41705	Energy Plan check only for Tenant improvement to install interior partitions and infill one door to (E) office. New ceiling and millwork. area scope 1353sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15271	17041-20003-03919	2484 E OLYMPIC BLVD	90021	14	121-5A219 158	5168002900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.0254	-118.22674	SUPPLEMENTAL CHANGES TO APPROVED SET CHANGES INCLUDE ADDING 2 NEW MANUAL TRANSFER SWITCH FOR FUTURE UTILITY GENERATOR HOOK UP.<<<<Plan check for power and energy. Project site is a new administration building and adjoining parking lot for an asphalt plant. Total lighting area = 3,800 sq. ft.Note: Building application has been generated under 16010-10000-05743>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15272	15041-20000-17106	16255 W SAN FERNANDO MISSION BLVD	91344	12	210B137   298	2681011036	C2-1VL, P-1VL, QC2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			Reviewed by Supervisor	06/25/2015 12:00:00 AM	ADDRESS	34.27208	-118.48642	Plan check for power and energy. Project site is an existing commercial building. Project scope is the installation of a new 800-amp service, (6) new panels, associated loads, and 15,960 sq. ft. of lighting.Note: Plan check fees were adjusted to fit the pre-printed check. (16) branch circuits are to be added to before permitting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15273	14041-20001-33960	18026 W RODARTE WAY	91316	5	165B125   242	2184033015	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM			PC Approved	01/12/2015 12:00:00 AM	PIN	34.14808234	-118.52586278	1/12/2015 - Plan check for modification to approved set. Standard plan. Add one module to string on 3kW inverter. Change roof layout.[pv1central string inverter standard plan system size 9.0kw.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15274	19041-10000-11369	19720 W VENTURA BLVD	91364	3	174B117   366	2164011024	C1-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.17232	-118.56318	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15275	10041-10000-24057	5745 W ARBOR VITAE ST	90045	11	093B169    66	4125010006	MR1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	33.95278	-118.38314	CONVERT TWO STORY, TYPE III-B, 145' X 208', OFFICE AND WAREHOUSE TO OFFICE AND AUTOMOTIVE BODY/FENDER REPAIR WITH SPRAY BOOTHS. NEW 800 SERVICE AND PANEL BOARD. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15276	13041-10000-35255	1188 S SAN PEDRO ST I	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	PIN	34.03375994	-118.25280059	Title 24 only changing fixrures existing circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15277	12041-10000-22730	500 W WORLD WAY Delta-Term 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	Renovation at the Delta offices at Terminal 5 at LAWA. Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15278	15041-10001-37056	15424 W SUNSET BLVD	90272	11	129B125   501	4412001017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.04806	-118.52795	Plan check for newly installed generator, including new ATS and relocation of existing panels. original permit #15041-10000-3756Replace Existing 100 amp 208v diesel generator with new Kohler Generator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15279	18041-10000-47978	6300 N CANOGA AVE 340	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.18492	-118.59722	PLAN CHEK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT IN EXISTING OFFICE SPACE - TOTAL AFFECTED AREA = 7622 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15280	12041-10000-03099	12119 N DARBY AVE	91326	12	219B121   412	2870001020	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2012 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	03/23/2012 12:00:00 AM	ADDRESS	34.29294	-118.54205	New PV system for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15281	17041-10000-19527	14845 W VENTURA BLVD	91403	4	168A149   189	2264017026	(T)(Q)C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.15238	-118.45654	PC FOR POWER AND ENERGY FOR NEW GROCERY STORE. NEW 3000A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15282	13041-10000-02339	7044 N VASSAR AVE	91303	3	183B105   488	2138003004	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			01/30/2013 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.19872	-118.60422	NEW FIRE ALARM SYSTEM IN A NEW 3 STORY CONDO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15283	16041-10001-02854	8731 W 3RD ST	90048	5	138B169   504	4334005013	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.07372	-118.38275	PC ONLY FOR A NEW LIGHTING IN AN OFFICE SPACE AND REPLACEMENT FIXTURE FOR THE RESTROOM. TOTAL SQ. FT. 132. PC FOR ENERGY ONLY.NOTE: INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT# 16041-70000-02854	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15284	17041-10000-17601	3611 S GRAND VIEW BLVD	90066	11	114B153   703	4248026040	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.00865	-118.43436	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10.25 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15285	16041-20000-00250	20951 W VANOWEN ST	91303	3	183B109   900	2138029024	[Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1349.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Issued	01/05/2016 12:00:00 AM	ADDRESS	34.19393	-118.59008	Plan check for energy and hazardous location only. Rebuilding gas station canopy, installing new lighting within drip line and on facade. Running new circuits to canopy to power lighting, conduit passes through Class I, Div 2 area of dispensing pump. Canopy is 1,242sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15286	12041-20000-29099	15821 W VENTURA BLVD #490	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.15584	-118.47812	Alteration to indoor lighting system in suite 490.   Plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15287	14041-10000-24896	6801 W HOLLYWOOD BLVD 1ST FLOOR	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Closed	02/22/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	"REPLACE EXISTING FACP  WITH NEW FACP MODEL ONLY ON 1ST FLOOR ELECTRIC ROOM. NEW MODEL NFS2-3030.INVESTIGATION FEE PAID UNDER 14041-10000-24897 ""COMPLY WITH DEPARTMENT ORDER effective date08/20/2014. PERMIT NEEDS TO BE PULLED 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15288	15041-20000-20050	16852 W BAHAMA ST	91343	12	195B133   156	2688027013	RA-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Expired	08/15/2017 12:00:00 AM	ADDRESS	34.23298	-118.49991	Addition of inverter and solar panels to existing roof mounted solar PV array.  Total system size = 11.6 kWac.  Three inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15289	10041-10000-06358	10250 W SANTA MONICA BLVD #470	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	05/03/2010 12:00:00 AM		Permit Finaled	06/10/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Plan check T-24 Energy (general/emergency) lighting for TI of retail store (#470) at Westfield	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15290	16041-10000-33414	8412 S LOYOLA BLVD	90045	11	096B161   391	4113008004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	33.96144	-118.41652	ROOF MOUNTED PV SYSTEN FOR SINGLE FAMILY DWELING USING 20 MODULES(TRINA SOLAR TSM-240 PC/PA05), WITH CENTRAL INVERTER (ABB PV1-5000)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15291	19041-10001-05587	2700 N VERMONT AVE	90027	4	153B193   686	5593002913	OS-1XL	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM			PC Approved	08/01/2019 12:00:00 AM	ADDRESS	34.11803	-118.29221	"08/01/2019PLAN CHECK ONLY. CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE RELOCATION OF ELECTRICAL PANEL, REMOTE RADIO UNITS AND REMOVAL OF OUTDOOR FIXTURE. NOTE ALL CHANGES ON CLOUDED AREA DELTA 1. _______________________________________Install new lights in the Verizon ""Head End Equipment Room"". T-24 Energy Only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15292	15041-10002-37840	462 E COMMERCIAL ST SERVICE-BLDG	90012	14	130-5A215  46	5173001905	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM			PC Approved	08/01/2017 12:00:00 AM	ADDRESS	34.05309	-118.23584	CHANGES TO AN APPROVED SET OF PLANS - PLAN CHECK FOR POWER ONLY.SCOPE OF WORK INCLUDES UPGRADE OF MAIN SERVICE FROM 4000A TO 6000A, RELOCATION OF MAIN SWITHCBOADS, AND RELOCATION OF EXISTING LOADS. SCOPE ALSO INCLUDES ADDITION TO EV BUS CHARGING STATION(6 TO 28) WITH NEW CONDUIT AND BREAKERS(NO EQUIPMENT).SERVISE LOAD CALCULATIONS HAVE ALSO CHANGED (TIED APPLICATION - 15041-10000-08748)(LOST SET APPLICATION 15041-10001-37840)PC only due to lost approved set.This is 5 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************ONE-STORY SERVICE BUILDINGSEE 15010-10000-01117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15293	19041-20000-29702	17729 W BULLOCK ST	91316	5	177B129   399	2159026006	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.17981	-118.5196	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 10.4KW DC/9.483KW AC. SCOPE OF WORK CONSISTS OF (32) PV MODULES WITH OPTIMIZERS, AND A SE11400H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15294	16041-10001-18367	4048 N BECK AVE	91604	2	162B169   390	2368023052	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.14125	-118.38312	Expedite per applicant request.(PV1 plan check for new solar system. AC system size 16 kW. 48 Canadian Solar modules. 2 SMA SB8000TL-US inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15295	13041-20001-27469	17521 W RAYEN ST	91325	12	195B129   196	2768026011	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.23233	-118.51668	Changes to approved set of plans.  Interconnect with 400A service.  Add 2 additional modules.  Note: Plan check and permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15296	16041-20000-30902	15730 W MORRISON ST	91436	5	168B141    54	2261006092	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.16063	-118.47599	Plan check for roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 150A.5kW ungrounded system. One 300W power optimizer per pv module. (21) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15297	14041-20001-02112	6935 N AMESTOY AVE	91406	6	183B133   656	2230003022	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	ADDRESS	34.19682	-118.50566	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8 KW AC USING 42 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15298	11041-10000-20269	5943 N RHODES AVE	91607	2	177B165  1085	2340002045	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.17862	-118.40332	Photo voltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15299	16041-10000-30032	15821 W VENTURA BLVD STE 520	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	T-24, PC FOR ENERGY ONLY FOR AN EXISTING OFFICE SPACE AT SUITE 520. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE WITHIN AN EXISTING BUILDING. TOTAL AFFECTED AREA IS 9785 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15300	19041-10000-52876	12121 W BLUFF CREEK DR	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	08/27/2020 12:00:00 AM		Permit Finaled	05/05/2021 12:00:00 AM	ADDRESS	33.97874	-118.40463	T-24 PLAN CHECK FOR A TI TO LOBBY AREA IN AN OFFICE AREA. SCOPE INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFETED AREA IS 55,008 SQFT. B#19014-10000-06948	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15301	12041-10000-21743	10866 W WILSHIRE BLVD	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.05907	-118.442	TENANT IMPROVEMENTS IN OFFICES AND CORRIDORS OF 14TH FLOOR OF A COMMERCIAL BUILDINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15302	17041-10000-07790	2900 W PICO BLVD	90006	10	129B193  1299	5074006016	C2-1VL-HPOZ, [Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.04703	-118.30328	PC for energy only. Removing and replacing HID fixtures with new LED ones. Area: 78,625	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15303	16041-10000-18358	714 W OLYMPIC BLVD 8TH FLR	90015	14	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.04454	-118.26341	PC TITLE 24  ENERGY ONLY .  OFFICE TI WITH NEW LIGHTING. (8TH FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15304	18041-10000-31490	130 S SOTO ST 1-5	90033	14	127-5A223 273	5180003030	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Apartment			08/20/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Issued	08/20/2018 12:00:00 AM	ADDRESS	34.04277	-118.21018	NEW ROOF MOUNTED PV SYSTEM USING MICROINVERTERS. (5) MODULES AND (5) ENPHASE MICROINVERTERS. TOTAL SYSTEM SIZE IS 1.2KW AC / 1.45KW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15305	11041-10000-14174	8500 W BEVERLY BLVD # 761	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT IN EXISTING RETAIL SPACEPLAN CHK IS FOR TITLE 24; PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15306	18041-10000-30609	14660 W RAYMER ST	91405	6	189B149   545	2210025008	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.21221	-118.45305	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15307	19041-20000-18499	3649 N WOODCLIFF ROAD	91403	4	162A145   203	2279014018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.13662	-118.46728	addition of (3) tesla powerwall ESS rated 5KWeach to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15308	13041-20000-19112	24526 W CRABAPPLE CT	91307	12	186B085   114	2031014011	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.20328	-118.65817	PV1 TRANSFORMERLESS SYSTEM 4.41 KW. 18 PANELS AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15309	17041-20000-18660	4667 N MORRO DR	91364	3	168A109    44	2172003003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.15564	-118.59089	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15310	13041-20000-30597	345 S LUCERNE BLVD	90020	4	135B189   328	5505018015	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.06767	-118.32457	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW AC USING 16 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 400A SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15311	10041-10000-08250	1118 N HIGHLAND AVE	90038	4	144B185   651	5532020008	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM			PC Info Complete	05/04/2010 12:00:00 AM	ADDRESS	34.09129	-118.3384	new retail store in existing buildingplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15312	19041-30000-26196	4965 S CENTINELA AVE	90066	11	105B161   126	4221023033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	12/07/2020 12:00:00 AM	ADDRESS	33.98734	-118.41678	Plan check for a fire alarm system for a 3-story, 25-unit apartment building. System consists of (1) FACP and (64) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15313	18041-10000-48964	12950 W VICTORY BLVD	91606	2	180B161  1112	2331032184	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.18651	-118.41539	REMOVE OUTDOOR HID FIXTURE AND REPLACE WITH NEW LED FIXTURES T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15314	15041-10000-07306	10900 W WILSHIRE BLVD PLAZA LEV-LOBBY	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.05848	-118.44419	CHANGING  INDOOR LIGHTING IN THE LOBBY AND ELEVATOR LOBBY AND OUTDOOR LIGHTING FOR THE BUILDING FACADE,WALKWAY AND HARDSCAPE AREASPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15315	16041-20000-45686	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.01303	-118.24279	PV2.  Install 1.68 MW roof mounted grid tied PV system.  (5309) modules with (21) 80 kW rated central inverters.  Frameless modules.  Feed-in-tariff project.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15316	16041-30000-15019	7485 W 80TH ST	90045	11	099B157   609	4114036029	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	03/05/2024 12:00:00 AM	ADDRESS	33.96386	-118.4283	Plan check for PV roof mounted system. System size: 5.2kWac with 21 modules and 21 microinveteres SFD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15317	18041-10000-38733	838 S LA BREA AVE	90036	4	132B181   409	5084003006	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Apartment			10/10/2018 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	03/15/2023 12:00:00 AM	ADDRESS	34.05947	-118.34487	Full plan check for a 6-story, 53-unit apartment building with 1-story subterranean garage located in a methane zone. Scope includes (1) 1600-Amp 120/208v 3-phase service with 9 typical panel. (((***25% PDPP partial plan check submittal for Zoning***New 6-story, 53-unit, mixed use apartment building with one story subterranean garage)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15318	18041-10000-20368	461 W 41ST ST	90037	9	115-5A201 236	5019026018	C2-1L	South Los Angeles	Southeast Los Angeles	Voices		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.00934	-118.28199	INSTALL A NEW 4.68 KW DC WITH 13 AC MODULES PV SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15319	14041-20000-04902	1888 S CENTURY PARK EAST #1600	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.06104	-118.41402	T.I. to a high rise building portion of 16th floor, suite #1625.  Install general/emergency lighting.  Plan check for energy only.Note: permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15320	14041-10000-17338	1443 N GORDON ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.09701	-118.32031	PC FOR POWER AND ENERGY. PARKING STRUCTURE. TOTAL AREA 11356 SQ FT. BLDG#14010 10 01956:  PARKING STRUCTURE ADDITION,  5  LEVELS,   TOTAL AREA 113,561 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15321	17041-10000-03890	706 N BAY VIEW AVE	90744	15	030B205   608	7416020037	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.77844	-118.26997	Plan check for Title 24 only in existing space remove outdoor includeing Title 24 Exempt Lighting in play ground HID Fixture and replace with new LED lighting fixtues. Total area: 14,930 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15322	17041-20000-36946	19781 W RINALDI ST	91326	12	210B117   379	2701040040	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.27517	-118.56478	pcaNew coffee kiosk in (E) supermarket.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15323	10041-10000-23443	6161 W CENTURY BLVD 1st floor	90045	11	090B165     6	4124030034	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	05/31/2011 12:00:00 AM	ADDRESS	33.94571	-118.39319	T-24 and emergency lighting plan check for the INTERIOR TI UPGRADES TO EXISTING HOTEL LOBBY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15324	14041-20000-17303	5808 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15325	19041-10000-02774	10250 W SANTA MONICA BLVD #2770	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK FOR FIRST TIME TENANT (WUSHILAND BOBA) - TOTAL AFFECTED AREA = 826SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15326	12041-10000-15636	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Issued	09/28/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check T24 Energy/Emergency lighting for office spaces on the 36th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15327	16041-30000-06737	3737 S BENTLEY AVE	90034	5	117B161   993	4252007041	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	Apartment			02/25/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.01482	-118.41685	Installation of fire alarm system in new 25 unit 5 story apartment building.  Total system size = 86 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15328	14041-20001-15630	240 N LARCHMONT BLVD	90004	4	138B189   501	5515025002	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM			Corrections Issued	09/08/2014 12:00:00 AM	ADDRESS	34.0758	-118.32344	Modification to approved set.  Change to number of lighting fixtures and type (wall-mounted bugeye units to drop-down unit equipment).  Adjusted sheets limited to E-3 and E-5.  (((Plan check for Energy only.New lighting and emergency lighting in single story restaurant. 855 sqft.Permit under separate application.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15329	12041-10000-18985	15359 W OXNARD ST	91411	6	177B145   440	2242001020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.17957	-118.46823	Replace existing underground process gravity drainage piline and UST with new lift stations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15330	15041-10001-35594	325 E WINDWARD AVE	90291	11	108B145  1532	4238008009	RD1.5-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM			PC Approved	02/08/2016 12:00:00 AM	ADDRESS	33.98981	-118.46864	**Revision on approved plan: removed 3 modules. Permit under 15041-10000-35594PV1, INSTALL 2.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(10) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15331	11041-10000-14875	700 W WILSHIRE BLVD 1st floor	90017	14	129A209    65	5144006020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM			PC Approved	08/15/2011 12:00:00 AM	ADDRESS	34.04863	-118.25733	T.I.  New restaraunt on theh ground floor of 7 story building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15332	13041-20000-13235	15359 W OXNARD ST	91411	6	177B145   440	2242001020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.17957	-118.46823	"One new control circuit (instrumentation) to a ""Prover Pad"".  Area is a hazardous classified area."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15333	15041-10000-04562	4901 S MARIONWOOD DR	90230	11	108B161   250	4218002907	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	33.99325	-118.41076	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3250 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15334	13041-20001-36326	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	34.07149	-118.19797	"FEE CHARGE $0.00 BY STATE SENATE BILL NO. 1222REVISIONS TO AN APPROVED SET OF PLANS.  CHANGE OF SUBPANEL FROM 3000AMP TO 2000AMP.((( "" $0 permit fee is due to the 2012 Senate Bill No. 1222"" )))PV2 COMMERCIAL ROOFTOP PHOTOVOLTAIC SYSTEM, TOTAL SYSTEM SIZE 3.89 MEGAWATTS AC. TOTAL OF 5.07 MEGAWATTS DC. USING TOTAL OF 141 TRANSFORMERLESS INVERTERS. ROOFTOP OF FOREVER 21 COMMERCIAL BUILDING. TOTAL OF 4 SERVICE INTERCONNECTIONS. USING TOTAL OF 15512 SUN POWER 327W MODULES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15335	19041-10000-23641	7500 N LAUREL CANYON BLVD	91605	2	186B165   345	2317012011	R1-1, R2-1, R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.20669	-118.39632	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15336	16041-10000-41397	14878 W NURMI ST	91342	7	222B149   925	2506009003	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.30236	-118.45683	PV1 SFD TOTAL SYSTEM SIZE 3KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. SYSTEM USES TOTAL 10 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15337	18041-20000-42952	2422 W IVANHOE DR	90039	4	148-5A207  50	5439017006	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.10236	-118.26144	PV1.  Install 3.48 kW roof mounted grid tied PV system. (12) modules with 3.0 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15338	10041-10000-19880	800 E 12TH ST # 123	90021	9	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	First tenant in new commercial space ; most of the loads are in place at time of core and shell approval	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15339	16041-10002-27704	1249 W 58TH ST	90037	9	108B197  1276	5002014016	RD1.5-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Expired	10/11/2018 12:00:00 AM	ADDRESS	33.98998	-118.29762	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012CHANGE TO APPROVED SET OF PLANS. CHANGES SHOW SINGLE INVERTER SYSTEM 6KW AC USING 16 MODULES IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15340	19041-10000-52082	13614 S VERMONT AVE	90247	15	078B197   321	6119001006	RD3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	33.90769	-118.29131	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 13  (HYUNDAI HIS-370KI) MODULES, 13  (ENPHASE IQ7PLUS-72) MICROINVERTERS CONNECTED TO AN EXISTING 100A MAIN SERVICE PANEL. SYSTEM SIZE IS 4.81KW DC & 3.77KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15341	14041-10000-27084	5800 S BROADWAY	90037	9	108B201  1307	5101024018	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM			Reviewed by Supervisor	10/07/2014 12:00:00 AM	PIN	33.98961269	-118.27793607	NEW SELF-SERVICE CAR WASH WITH 5 EA WASH BAYS AND  7 VACCUM CANOPY BAYS.  1608 S.F.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15342	13041-10000-21168	6049 N CALVIN AVE	91356	3	177B117   545	2153029002	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM			Corrections Issued	08/07/2013 12:00:00 AM	ADDRESS	34.18069	-118.55631	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN. SYSTEM SIZE IS 10.78 KW DC AND 7.5 KW AC. 44 MODULES IN 4 STRINGS OF 11. 1 COMBINER BOX. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: FRONIUS # IG PLUS V 7.5]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15343	17041-20000-32856	11755 W WILSHIRE BLVD 14th Floor-Restrooms	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for Title 24 only. Project site are common area restrooms of the 14th floor of a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 556 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15344	13041-20000-21299	12206 N STEWARTON DR	91326	12	219B121   285	2820018040	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.29407	-118.54452	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 8.6 KW USING TOTAL OF 40 MODULES. USING MICRO INVERTER ENPHSE M215 STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15345	16041-20000-03636	11465 N GLADSTONE AVE	91342	7	213B165   569	2531015022	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.27864	-118.3939	PV1. Install 9.975 kW roof-mounted, utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15346	12041-20000-06353	21101 W VENTURA BLVD	91367	3	171B105    23	2167001010	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	02/04/2013 12:00:00 AM	PIN	34.16772917	-118.59308863	Common areas hotel renovationEnergy, emergencyRequest for Modification to separate Fire Alarm system filed .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15347	13041-20000-13845	1022 S WELLESLEY AVE	90049	11	126B145   119	4264022038	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.04455	-118.4709	New ungrounded photovoltaic system for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15348	14041-10000-12530	4177 W WASHINGTON BLVD	90019	10	126B185   973	5072001034	C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM			PC Approved	05/12/2014 12:00:00 AM	PIN	34.04016215	-118.33060789	permit to be pulled at EPC counter only. Plan check for energy only.  TI (e) starbucks for added task lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15349	19041-10001-24710	4671 E WORTH ST	90063	14	135A233   232	5223002015	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	06/25/2020 12:00:00 AM		Permit Finaled	04/13/2022 12:00:00 AM				"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  ""A"". CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM, RELOCATING LOADS ON PANEL SCHEDULES, AND REVISING FLOOR PLANS TO REFLECT AS BUILT.NOTE: NARRATIVE HAS BEEN PROVIDED."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15350	14041-10001-13984	622 S ANDERSON ST	90023	14	126A219   105	5171006012	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.03834	-118.22362	CHANGE TO APPROVE SET THE CHANGES ARE, CHANGE UNDER GROUND SERVICE TO OVER HEAD, CHANGE ELECTRIC ROOM AND CHANGES SHOULD BE INDICATE IN DELTA 2(((((P.C for power and energy. PROPOSED DEMISING WALLS TO DIVIDE TENANT SPACES (INTERIOR) into 8 spaces OF EXISTING 14,745 S.F. WAREHOUSE SHELL ONLY. Plea)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15351	13041-20000-35125	10370 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	01/09/2014 12:00:00 AM	ADDRESS	34.25886	-118.57962	PC FOR T24 ENERGY ONLY. OFFICES WITH NEW LIGHTING. INSIDE BANK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15352	14041-10000-00034	701 E NEW DOCK ST MARINE-TOWER	90731	15	024B209   298	7440021914	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.75567	-118.25325	NEW FIRE ALARM SYSTEM FOR MARINE TOWER CONSISTING OF 56 DEVICES, 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15353	12041-10000-20558	3162 N DONA CRISTINA PL	91604	2	156B169    54	2381008021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.12783	-118.38281	7.92 kw roofmounted solar for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15354	13041-10000-19489	7449 N CALVIN AVE	91335	3	186B117   464	2116016043	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	ADDRESS	34.20606	-118.55584	PLAN CHECK ONLY IN REFERENCE TO APPLICATION NUMBER 13041-20000-16583. PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. SYSTEM SIZE IS 7.350 KWDC. [MODULES: TRINA SOLAR # TSM-245PC/PA05 |||| INVERTER: FRONIUS # IG PLUS V7.5] PERMIT TO BE PULLED FOR THE DIFFERENCE UNDER A SEPERATE APPLICATION NUMBER: 13041-10001-16583.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15355	18041-10000-15743	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM			Corrections Issued	05/09/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	PC FOR T-24 ENERGY ONLY FOR A COURTYARD IMPROVEMENTS. SCOPE INCLUDES NEW PANELS, LIGHTING AND RECEPTICAL. TOTAL AFFECTED AREA IS 12474 SQ.FTB# 18020-10000-01033	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15356	18041-20000-42211	8900 N DE SOTO AVE bldg 105	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.23162	-118.58832	ti to an existing commercial building.  adding new lighting new controls to exisitng panels.  plan check for power and energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15357	10041-20000-21688	8426 N SAN FERNANDO ROAD	91352	6	192B173   326	2632027015	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.22302	-118.37377	PLAN CHECK FOR 19.44KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15358	16041-20000-15496	21650 W OXNARD ST Ste 1970	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Existing commercial office remodel in commercial highrise building.  All new lights, all existing circuits.  Plan check for energy.  1678 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15359	17041-10001-43571	1523 W GRIFFITH PARK BLVD	90026	13	144A203    19	5429022004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.09067	-118.27718	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION (UNDER DELTA 1) SCOPE INCLUDES ADDING NEW LIGHTS AND RELOCATION OF LIGHTS IN SPACE. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER. T-24, PC FOR ENERGY ONLY. TENANT IMPROVMENT TO AN (E) COFFEE SHOP AND REMODEL BATHROOM. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 100 SQ. FT. B#17016-20000-26904	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15360	15041-20000-24920	6255 W SUNSET BLVD 15TH FLOOR	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HALLWAY AND LOBBY ON 15HT FLOOR. 1536 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15361	10041-20000-15802	1700 E 4TH ST	90033	14	127-5A219 318	5171023001	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Apartment			08/12/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	ADDRESS	34.04273	-118.22151	PLAN CHECK FOR EXISTING BUILDING CONVERTING TO 12 LIVE/WORK RESIDENTIAL UNITS AS PER ADAPTIVE REUSE ZONING CODE.  REF.#10042-10000-15761	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15362	12041-10000-28255	923 S HARVARD BLVD	90006	10	132B193   981	5093016025	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.05508	-118.30429	PV1 12 KW DC ROOF-MOUNT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15363	13041-20000-01926	14141 W VENTURA BLVD	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	New restaurant in shell building, full plan check. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15364	15041-10000-16573	4100 W JEFFERSON BLVD	90016	10	120B181   760	5046006005	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.02542	-118.34077	TI for (E) fire-damaged auto repair shop.  Not hazardous classified per applicant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15365	13041-10003-32727			11	102B161  1251	4211034032	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/22/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	PIN	33.9794969	-118.41171061	Change to approved set by changing tenant panel feeder from Aluminum to Copper. all feeder-size remains the same. All changes are under delta-32. only. (((Plan check for power and energy. Fire alarm variance filed 6/19/2014.NEW 83 UNIT SENIOR INDEPENDENT APARTMENT OVER ONE STORY SUBTERENEAN GARAGE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15366	16041-10000-40347	17600 W RINALDI ST	91344	12	213B129   298	2711022004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.2792	-118.51781	PV INSTALL NEW 12375 W DC ROOF-MOUNTED SOLAR ARRAY ON  A SINGLE FAMILY HOUSE.(45) MODULES: REC SOLAR REC275TP(2) INVERTERS: NINGO GINLONG TECHNOLOGIES SOLIS-3-6K-2G-US AND (1) 3K	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15367	19041-10000-16399	5760 W ARBOR VITAE ST	90045	11	093B169    79	4125020014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Issued	05/03/2019 12:00:00 AM	ADDRESS	33.9525	-118.38238	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15368	19041-10000-01502	10250 W SANTA MONICA BLVD 2450	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for first time T.I. for medical office expansion. Scope includes new 100A panle, lighting and receptacles. Total affeceted area is 5009 sq.ftB# 19016-10000-00597	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15369	16041-20000-15439	1127 W WILSHIRE BLVD #800	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Info Complete	06/14/2016 12:00:00 AM	ADDRESS	34.05287	-118.26415	Plan check for power and energy. Project site is the 8th floor of an existing high-rise building. Project scope is a tenant improvement to a medical office. Total lighting area = 3,505 sq. ft.Note: Building application has been created under 16016-10000-09475	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15370	17041-20000-27817	3502 S TROUSDALE PKWY Suite B15	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	ADDRESS	34.02175	-118.28408	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 365 sq. ft.Note: Building application has been generated under 17016-10000-13035	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15371	12041-10000-23590	8359 S STEWART AVE	90045	11	096B161   351	4112017015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	33.9616	-118.40755	FOR A SFD, ROOF-MOUNTED 2.45KW PHOTOVOLTAIC SYSTEM USING MICROINVERTERS.  Maximum Enphase Engage cable length is 51'.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15372	13041-10000-12634	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	Tenant improvement on 3rd fl of an office buildingplan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15373	14041-20001-05871	23824 W TIARA ST	91367	3	177B089   733	2045016010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.17853	-118.64555	Changes from previously approved plans.  Change only in inverter model number.Note: Plan check and permit fees are $0.00 due to Senate Bill 1222 from 2012.*****Previous description:Roof mounted PV system with 5.9KWdc.Note: Permit include 225A panel upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15374	19041-10000-22733	4054 S DEL REY AVE #204	90292	11	108B149  1198	4230004023	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Issued	06/14/2019 12:00:00 AM	ADDRESS	33.98957	-118.44597	Energy plan check for removing HID fixture and replace with new LED fixture to cover a total lighting area of 680-SQ FT (indoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15375	14041-10000-08640	6740 N AGNES AVE	91606	2	180B165    89	2322010007	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.19323	-118.39526	PV1, INSTALL 6.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U(27) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15376	19041-10000-11031	11051 W VENICE BLVD 1-3	90034	5	117B161  1058	4252008034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.01418	-118.41554	NEW ROOF MOUNTED 3.05KW PV SYSTEM WITH 10 PV PANELS ON A SINGLE FAMILY / DUPLEX HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15377	14041-10002-27933	7909 W ROSEWOOD AVE	90048	5	141B177  1153	5527020009	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM			PC Approved	03/02/2015 12:00:00 AM	ADDRESS	34.08022	-118.36192	Changes to approved set under inspection comments by adding case strip lighting; all changes in this application are under clouded area, delta-1 only.(((Modifications to approved set.  As-built plan check to address inspection comments.  (((Title 24 plan check only.  Total area = 1272 sq. ft.T.I. to existing retail space.  New lighting and recepticles.))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15378	13041-20000-14485	16300 W ROSCOE BLVD	91406	6	192B137   316	2689023001	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM			PC Approved	06/04/2013 12:00:00 AM	ADDRESS	34.22111	-118.48765	T24 FOR OUTDOOR PARKING LOT. RELOCATING MORE THAN 50% OF THE LIGHTING AND ADDING NEW LIGHTS. TOTAL SQRFT 191,635.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15379	11041-10000-17389	7135 N WILBUR AVE	91335	3	183B121   202	2129035014	[T][Q]RD1.5-1	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.20032	-118.54502	NEW FIRE ALARM FOR NEW BUILDING.  ELECTRICAL PLANS HAVE ALREADY BEEN SUBMITTED ON SEPERATE PLAN CHECK NO. PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15380	12041-10000-11160	12121 W WILSHIRE BLVD #1350	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/15/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	PIN	34.04391963	-118.46825257	T.I. to an existing high-rise office building, lighting and receptacle changes.  Load is 2A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15381	14041-20000-03279	9301 N TAMPA AVE 9	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC FOR T24 ENERGY ONLY. RETAIL SPACE NEW LIGHTING. TOTAL AREA 5416 SQ FT. USING TAILORED METHOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15382	17041-10000-35953	1082 S GLENDON AVE	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.06097	-118.44424	PC FOR POWER AND ENERGY FOR TENANT IMPROVEMENT FOR MEDICAL OFFICE. NO CHANGE IN EXISTING USE OR OCCUPANCY.  OFFICE IN A HIGH RISE BUILDING. SCOPE INCLUDES NEW PANEL, EQUIPMENT AND CIRCUITS. TOTAL AFFECTED AREA 1000 SQ.FT. B# 17016-10000-27052	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15383	16041-20000-34254	20940 W BURBANK BLVD	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.17302	-118.58923	Replacement of 3-story medical office building's exit signs with new LED exit signs.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15384	15041-20000-12082	3930 N LAUREL CANYON BLVD 1-69	91604	2	162B165   407	2369019032	R4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Apartment			04/22/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.14177	-118.39441	PERMIT FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 32.365 kWac.  System has three 10 kWac central inverters AND eleven 215 Wac microinverters connected to a  common 200 A subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15385	10041-20000-12559	8755 N WOODMAN AVE	91402	7	195B153   900	2637004036	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	PIN	34.22896531	-118.43609748	FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15386	15041-10000-35402	1362 N WESTERN AVE	90027	13	147A193   205	5544032013	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.09614	-118.30905	New multilevel parking structure with five interior levels and a roof. PC for power and energy. Main switchgear: 600 Amps. Total Sq Ft = 135305.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15387	18041-20000-42789	11601 W WILSHIRE BLVD Suite 2500	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 only. Project site is an existing tenant suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,653 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15388	13041-20002-35784	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM			PC Approved	02/04/2015 12:00:00 AM	ADDRESS	33.97749	-118.41246	CHANGES TO APPROVED SET OF PLANS. THIS PC COVERS CHANGES CLOUDED DELTA 15. THIS IS A PRECURSOR TO CHANGES CLOUDED DELTA 16. THIS WILL COVER DELTA 15, CHANGES TO CORE AND SHELL DESIGN.PC ONLY. NO PERMIT ISSUED OFF THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15389	16041-10001-02298	11975 W BLUFF CREEK DR	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	33.98224	-118.40247	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW PANELS, 2 ATS' AND  ONE NEW TRANSFORMER. TOTAL CONNECTED LOAD >400 AMPS. T-24 IS UNDER THE MASTER 16041-10000-02298.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15390	16041-20000-45056	6611-6639 N RESEDA BLVD	91335	3	180B125   833	2126038026	(T)(Q)RAS4-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.19075	-118.53639	Plan check for power and energy. Mixed Use - 5-Story 250-unit  Apartment over 1 story  parking / Retail. (2) 208Y/120V 3ph-4w services at 4000 and 5000A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15391	16041-20001-26321	7654 N TAMPA AVE	91335	3	186B117    46	2104012038	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Approved	08/23/2016 12:00:00 AM	ADDRESS	34.20985	-118.55333	Expedite per applicant request{{{{{Plan check for PV2 roof mounted system. System size: 70kW with 2 inverters(15kW), 2 inverter(20kW) with 202 modules connected to MSP1 and MSP2}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15392	11041-20000-20230	2900 N HYPERION AVE	90039	4	151-5A205 110	5434027027	C4-1D	Central	Hollywood	Silver Lake		1882.01	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	PIN	34.10939029	-118.27088676	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15393	16041-10000-25749	5733 S WILTON PL	90062	8	108B189  1193	5005012021	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	33.98996	-118.31508	PV1, INSTALL 3.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: CANADIAN SOLAR CS6P-260(1) INVERTER:FRONIUS PRIMO 3.8-1 24V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15394	16041-10000-08667	2323 S COTNER AVE	90064	5	123B153    44	4322023037	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM			Reviewed by Supervisor	03/21/2016 12:00:00 AM	ADDRESS	34.03727	-118.43775	PC FOR POWER ONLY,  REPLACE SPRAYBOOTH WITH NEW SPRAYBOOTH WITH ATTACHED HEATER, SERVICE IS UPGRADED TO 400 AMPS.  HAZARDOUS EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15395	19041-20000-42740	283 N TRINO WAY	90272	11	126B121   503	4415030011	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	01/19/2021 12:00:00 AM	ADDRESS	34.04125	-118.5445	PV1. INSTALL 15.360 KW DC PV SYSTEM WITH (48) MODULES/ENPHASE MICROINVERTERS AND (2) TESLA POWERWALL BATTERIES.Fees $31.36 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15396	13041-10000-34989	3325 N WRIGHTWOOD DR	91604	2	159B173   399	2380014039	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.13194	-118.37495	PV1, ROOF-MOUNTED SOLAR ARRAY INTERCONNECTING WITH (E) 200A MAIN SERVICE. SYSTEM SIZE IS 6.048 kW AC, 6.3kW DC. ENPHASE M215 MICROINVERTER ON STANDARD PLAN, WITH 28 MODULES (WATTON WTM225 ), (1) 60A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15397	10041-10000-25323	10100 W SANTA MONICA BLVD 4th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	05/24/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	Ti in an existing office building. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15398	11041-20000-06313	17777 W VENTURA BLVD # 200	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	TI Unit # 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15399	19041-20000-16136	20709 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	10/26/2019 12:00:00 AM	ADDRESS	34.29318	-118.58506	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15400	11041-20000-09765	21720 W SHERMAN WAY	91303	3	183B105   168	2111025005	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.20085	-118.60233	PLAN CHECK POWER AND ENERGY COIN LAUNDRY WITH NEW 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15401	12041-10000-16668	13433 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15778	-118.42608	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15402	13041-20000-34542	5152 N TOPANGA CANYON BLVD	91364	3	171B101   861	2169005014	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.16331	-118.6056	New rooftop PV system using DC-DC converters.  System is UNGROUNDED.  New subpanel and relocate 2 circuits.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15403	18041-10000-03250	21419-21421 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.2574	-118.5979	PC for T24 only for new lights beauty salon TI. Installing two new panels, receptacles, lights and equipment. Total area is 2172sqft. B# 18016-10000-02822.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15404	10041-20000-19282	8471 W MELROSE PL 2nd Floor	90069	5	141B173   425	5528001056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	09/28/2010 12:00:00 AM	ADDRESS	34.08374	-118.37567	T.I. to existing building in 2nd floor.  Install general lighting.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15405	10041-20000-16234	2300 W 3RD ST	90057	1	135A203   214	5154035029	C2-1	Central	Westlake		YES	2088.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.06402	-118.27494	energy plan check banquet hall st nicholas church	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15406	13041-20002-19758	1900 S LINCOLN BLVD	90291	11	108B149    31	4242006001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	33.9961	-118.45652	(((CHANGES MADE TO APPROVED SET OF PLANS. ALL CHANGES HAVE BEEN CLOUDED. CHANGES MADE TO T24 AND SOME NEW CIRCUITS)))new restaurant. pc for power and energy. place of assembly. 600a service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15407	19041-10000-14312	22831 S FRAMPTON AVE	90501	15	045B197    50	7347018031	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	33.81817	-118.2997	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15408	14041-20000-20304	2055 S BARRINGTON AVE	90025	11	123B149   273	4262031012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	34.03581	-118.44934	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY ONLY.  ONE STRORY COMMERCIAL BUILDING 12,757SQFT.  NEW LIGHTING LOADS AND SUBPANELS ADDED.  THIS PLAN CHECK IS IN ADDITION TO INTERNET PERMIT NUMBER 14041-90000-09959.Replace existing lightingAdd new lights in rest roomReplace existing sup panels	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15409	14041-10000-19358	5756 W MELROSE AVE	90004	4	141B189   340	5523011025	C1-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Apartment			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	PIN	34.08334029	-118.32513041	PV2 1.53KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(6)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15410	14041-10000-21146	4515 N SHERMAN OAKS AVE	91403	11	888000983	2283017002		North Valley				1414.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM				PV1, INSTALL 1071 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(42) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERs: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15411	19041-20000-36254	6344 N TOPANGA CANYON BLVD #1030	91367	3	180B105    60	2146029022	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.18628	-118.60544	T24 PLAN CHECK FOR CHANGE OF USE TI FROM BAKERY TO SANDWICH SHOP. LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 987 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15412	14041-20000-04229	6438 N ALDEA AVE	91406	6	180B133   450	2230022007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Expired	05/03/2016 12:00:00 AM	ADDRESS	34.1879	-118.50777	pv1 single family dwelling. total system size 6kw ac using transformerless inverter nonstandard plan. using string combiner for dc system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15413	17041-20000-00937	3673 S WELLINGTON ROAD	90016	10	117B185    43	5046027005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2017 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.02073	-118.33841	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (23) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15414	14041-10003-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			11/16/2016 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	33.95605	-118.38499	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGES FROM COPPER FEEDERS TO ALUMINUM FEEDERS. CHECKING FOR NEW SIZING AND AIC RATINGS. NOTE: PERMIT IS PAID UNDER PCIS#14041-10000-15889	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15415	14041-20000-09653	518 E 15TH ST	90015	14	123A209   136	5133021011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM			PC Info Complete	04/25/2014 12:00:00 AM	ADDRESS	34.03166	-118.25751	upgrade services from 400 A to 600 A and from 50 A to 100 A taped from same DWP drop. PERMIT WAS PULLED UNDER APPLICATION#: 14041-20000-10907 DUE TO TECHNICAL DIFFICULTIES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15416	16041-10001-43247	11715 N SHOSHONE AVE	91344	12	213B129   415	2601069008	RE40-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM			PC Approved	01/05/2017 12:00:00 AM	ADDRESS	34.28237	-118.51671	PC FOR PV SIZE 10440 AC  ROOF MOUNTED SINGLE FAMILY DWELING.INCLUDES: 29  INTIGRATED AC MODULES SPR-X22-360-C-AC1 NEW LOAD CENTER 125A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15417	16041-20000-12059	11423 N PORTER RANCH DR	91326	12	213B113   325	2701072004	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.27864	-118.57253	Plan check for a PV2 carport-mounted PV system. System size is 150 kWac and consists of (10) inverters, (600) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15418	19041-20000-07099	8000 N KEOKUK AVE	91306	3	189B113   473	2107017166	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.21578	-118.57439	Plan check for PV roof mounted system, system size: 11.88 KW DC, 10.93KW AC CEC with 36 PV Modules Panasonic 330W and 36 Enphase microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15419	12041-10006-29911	"12722 W MILLENNIUM BLDG ""B"""	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	33.9761	-118.41564	CHANGES TO UNITS FLOOR PLANS- LUMINAIRES ABOVE THE ISLANDS IN THE KITCHENS ARE REMOVED AND REPLACED WITH J-BOXES FOR FUTURE HIGH EFFICACY PENDANT LUMINAIRESPLAN CHECK ONLY(((((((((PLAN CHECK POWER AND ENERGY FOR NEW 4-STORY 103 UNIT APARTMENT COMPLEX. BUILDING 'B'.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15420	15041-10000-01351	7112 N CANBY AVE	91335	3	183B125   320	2125002005	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM			PC Approved	01/30/2015 12:00:00 AM	ADDRESS	34.1998	-118.53462	Title 24 plan check only.  Total area = 4,300 sq. ft.Installation of new walls dividing up existing storage space and new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15421	11041-10000-19366	695 S VERMONT AVE 14th floor	90005	10	132B197   178	5094008026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM			PC Approved	09/13/2011 12:00:00 AM	ADDRESS	34.06016	-118.29183	T-24 only lighting plan check.  A small portion of the 14th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15422	17041-20000-20622	921 S WESTWOOD BLVD 3RD FLOOR	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.06327	-118.44558	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 3RD FLOOR AFTER FIRE DAMAGE. "" PRINCETON REVIEW "" 3572 SQFT.building p# 17016-20000-15416"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15423	14041-20000-32229	1381 W AMAR ST	90732	15	018B193   113	7446004003	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	33.74769	-118.30603	PV1Install roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size 3.8kW. Ungrounded system.12 327W pv modules across two strings (6+6).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15424	14041-20000-11174	130 E KETCH MALL	90292	11	102A147    68	4295002055	R1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Expired	05/23/2016 12:00:00 AM	ADDRESS	33.97447	-118.45944	Change from previously approved plans (14041-10000-03182) to microinver.   Roof mounted PV system with microinverter.  System size 8.64KW.Note: Permit for the modules and pv load center is on 14041-10000-03182.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15425	09041-20002-15121	2920 S SEPULVEDA BLVD	90064				C2-1VL, R4P-1		West Los Angeles	Westside			Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	07/13/2011 12:00:00 AM	ADDRESS	34.02823	-118.42906	revision to title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15426	19041-10000-37033	434 N FORMOSA AVE	90036	5	141B181  1358	5525027022	R1V2	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.07921	-118.34609	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 11.4 KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 39 MODULES USING P400 OPTMIZERS AND 2 ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15427	13041-10001-29232	12105 W ART ST	91352	6	195B165   482	2634037020	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.2297	-118.39662	][][]EXPEDITED PER APPLICANT REQUEST ][][][PV1, ROOF-MOUNTED SOLAR INSTALLATION INTERCONNECTING WITH EXISTING 200A MAIN SERVICE. XFORMERLESS SYSTEM DONE ON  NON-STANDARD PLAN. SYSTEM SIZE IS 5.886 KW DC AND 6.00 KW AC, WITH 18 MODULES (SUNPOWER; SPR-E20-327) AND 1 INVERTER (POWER-ONE; PVI-6000-OUTD-US)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15428	11041-10000-04160	600 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	NEW CONVEYOR BELT SYSTEM FOR ALASKA AIRLINES, TERMINAL 6, LAX.  18 NEW PANALES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15429	15041-20004-10971	1355 N GARDNER ST	90046	4	147B177  1280	5550024015	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Closed	11/04/2015 12:00:00 AM	ADDRESS	34.09593	-118.35301	7/21/15 changes to approved set of plans to match existing service.  changes to the solar system. two single phase inveter 7.6 inveters. and addition of a subpanel connected to 400 amp 120/240 service.[[[Installation of new roof mounted solar PV array.  Total system size = 14 kWac.  Single inverter system.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15430	17041-10000-01009	10126 N LUBAO AVE	91311	12	204B113   415	2726023005	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.25455	-118.56875	PV1. Plan check for PV roof mounted system. System size: 6.0kW with 1 inverter(Solaredge SE6000A-US) and 28 modules (HAMWHA Q-CELL)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15431	17041-10000-40915	7330 N CRANER AVE	91352	2	186B173   892	2410017024	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Issued	11/13/2017 12:00:00 AM	ADDRESS	34.20381	-118.36907	PC FOR 3.8KW ROOFTOP PV. INSTALLING 18 MODULES WITH OPTEMIZERS AND ONE CENTRAL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15432	16041-10000-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	PLAN CHECK FOR POWER AND TITLE-24BUILDING PERMIT #16016-10000-11862SCOPE OF WORK DENOTED BY DASHED AND SOLID LINES.  FACILITY IMPROVEMENT FOR TERMINAL 2 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUS OPERATION, AND OFFICE RENOVATION.  17 NEW PANELS TIED IN TO EXISTING POWER DISTRIBUTION SYSTEM WITH ASSOCIATED LIGHTING AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15433	17041-20000-01688	5716 N KELVIN AVE	91367	3	174B109   221	2151020046	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.17487	-118.58647	"""0$ permit fees due to senate bill 1222 ""Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.15.2kW ungrounded system. (54) 315W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15434	19041-10000-09657	9623 W VENICE BLVD	90232	5	120B165   816	4313016040	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.0249	-118.39659	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15435	13041-10001-36145	7925 S NAYLOR AVE	90045	11	099B165   674	4107001012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	33.96624	-118.39547	Epedited RSES plan check has moved to supplemental 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15436	12041-10001-01340	241 S RIMPAU BLVD	90004	4	135B185    73	5515008015	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.06934	-118.33047	New roof mounted 17.9KW photovoltaic system single family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15437	17041-20001-30125	15926 W HAMLIN ST	91406	6	180B141   834	2233014016	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.1876	-118.48031	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 5 kWac and consists of (1) inverter, (16) modules, (1) Tesla Powerwall, and (2) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15438	17041-20000-37035	627 N DILLON ST	90026	13	141A203   351	5401014015	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Apartment			10/16/2017 12:00:00 AM	01/25/2021 12:00:00 AM		Permit Finaled	04/08/2024 12:00:00 AM	ADDRESS	34.07914	-118.27881	Plan check for power and energy. Project site is a new 4-story, 30-unit apartment building over 1-story of basement parking garage. Work includes a new 1,600-amp service and a total lighting area of 31,570 sq. ft.Note: Building application has been generated under 17010-20000-02602	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15439	11041-10000-11171	5331 E HUNTINGTON DR NORTH Bldg #2	90032	14	145-5A237 252	5309017036	(T)[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Apartment			06/01/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	01/24/2012 12:00:00 AM	ADDRESS	34.09124	-118.16464	New fire alarm with 67 devices and 2 panels for Building 2 (out of 3 buildings).  Building 1 PCIS # is : 11041-10000-11167  Building 3 PCIS # is: 11041-10000-11173	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15440	11041-10000-12798	444 S FLOWER ST #4100	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	T.I.  Converting one room into three offices.  Plan heck is for energey only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15441	15041-20001-18966	3733 S MOTOR AVE	90034	5	120B165  1312	4314003036	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	34.02181	-118.40526	Expedited per applicant requestPlan check for a PV2 roof-mounted PV system. System size is 18 kWac and consists of (2) inverters, (100) modules, (100) power optimizers, (1) load center, and (2) combiner boxes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15442	12041-10003-02898	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM			PC Approved	05/02/2012 12:00:00 AM	ADDRESS	34.0446	-118.21143	Delta 2 revision to approved plans. Plan check for sizing service conductor from weather head. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15443	17041-10000-20904	11601 W WILSHIRE BLVD 22ND FLR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR RESTROOM  TI  FOR TITLE -24  ENERGY ONLY. INSTALLING NEW LIGHTS AND RECEPTACLES (ALL EXISTING CIRCUITS)TOTAL AFFECTED AREA 422 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15444	19041-10000-48627	526 N VERMONT AVE	90004	13	141B197   895	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.0807	-118.2915	PLAN CHECK FOR T-24, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS.  TOTAL SQUARE FOOTAGE: 4965 SQ FT. SUBJECT TO FULL POWER PLAN CHECK DEPENDING ON FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15445	12041-10000-14874	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Closed	12/18/2012 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check for power and energy. Dental Office. 2200 sqft. Low rise commercial building (6 floors).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15446	14041-20000-01489	16220 W ARMSTEAD ST	91344	12	213B141    42	2605019022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.28279	-118.48536	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 5KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15447	18041-10000-32691	336 W 33RD ST BUILDING-#1	90007	9	120A203   218	5122020002	[T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			Reviewed by Supervisor	09/05/2018 12:00:00 AM	ADDRESS	34.02166	-118.27685	FULL PLAN CHECK FOR (2) BUILDING WITH (2) APPLICATION UNDER (1) PLAN OF THE SAME LOT. THIS APPLICATION IS FOR BUILDING #1, 1 OF THE 2, NEW 2-STORY LIGHT CLOTHING MANUFACTURING BUILDING LOCATED IN THE SAME LOT. SCOPE INCLUDE ONE 800-AMPS 120/240V 3-PHASE 4-WIRE SUPPLYING THE TWO BUILDING.2ND BUILDING #: 18041-10000-32689REFERENCE BLD #: 16010-10000-02095.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15448	18041-10001-27862	20221 W PRAIRIE ST	91311	12	198B113   119	2748038030	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.23931	-118.57365	EXPEDITE PER APPLICANT REQUESTInstall Rofftop solar system in a Commercial Building, Build.-C.System size, 42.48 kWptc39kW DC/ 33kW AC. SCOPE INCLUDES (120) modules, (60) optimizers, (1) central string inverter, TO BE CONNECTED TO EXISITING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15449	15041-10000-12202	11766 W WILSHIRE BLVD #1400	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.04804	-118.46227	Energy plan check for an office TI. located at 14th floor (Globalwide Media) of a high rise building. Scope includes installing new lighting and receptacles in the floor plan with all existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15450	18041-20000-45107	2514 S MEDLOW AVE	90041	14	159A219   287	5684035009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.12943	-118.22273	Plan check for a PV1 roof-mounted PV system. System size is 7.78 kWdc/7.7 kWac-CEC and consists of (25) modules, (25) micro-inverters, (2) load centers, and (1) back-up battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15451	18041-10000-38876	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.21499	-118.4422	Remove outdoor HID fixtures and replace with new LED fixtures - T-24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15452	14041-10000-35604	18740 W OXNARD ST #302	91356	3	177B121   594	2156019049	(Q)P-1, MR1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.18001	-118.54246	Title 24 plan check only.  Total area = 2,856 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15453	18041-10000-00591	760 N HOOVER ST	90029	13	142-5A201 134	5427010005	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Apartment			01/05/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	03/31/2022 12:00:00 AM	ADDRESS	34.08527	-118.28424	PC FOR SERVICE UPGRADE TO 600A 120/240V FOR APRTMENT BUILDING. SCOPE INCLUDES NEW SERVICE PANELS AND FEEDERS ALL LOADS TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15454	18041-10000-34688	6817 W FRANKLIN AVE	90028	4	150A185   287	5549018024	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.10427	-118.33904	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15455	17041-10000-40577	3810 S CRENSHAW BLVD	90008	10	117B185   617	5033003005	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	34.01681	-118.33474	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15456	19041-10000-23575	7332 N ETHEL AVE	91605	2	186B161   518	2327015017	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.20395	-118.41803	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15457	13041-20000-16690	10886 N LEHIGH AVE	91331	7	210B161   772	2534022012	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	34.26796	-118.41534	REPLACE CONTROL PANEL ONLY. REMOVE EXISTING AND REPLACE WITH NEW. ALL SPECIFICIATIONS TO REMAIN THE SAME (LIKE FOR LIKE REPLACEMENT.) PC FOR NEW CONTROL PANEL. AL DEVICES EXISTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15458	14041-10000-05211	421 S MAIN ST	90013	14	129A211    92	5149022010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.04765	-118.24788	TI to existing commercial space for new restaurant.  Restaurant occupancy load below 100 occupants.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15459	17041-10000-37589	10831 W PICO BLVD	90064	5	126B157   908	4320002062	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.04035	-118.42839	Plan check for Title 24 only in existing space use existing panels lighting and receptacles. Total area: 656 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15460	14041-20000-22252	8115 W MELROSE AVE	90046	5	141B173   387	5528007012	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.08388	-118.36643	TI to single-story (E) commercial retail building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15461	17041-10000-03409	11970 W VENICE BLVD	90066	11	114B157  1256	4214022904	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.00613	-118.42855	PC for indoor title 24. Removing HID fixture and replacing them with new LED ones. Area: 7,300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15462	15041-10000-05018	11738 W COURTLEIGH DR	90066	11	111B161   724	4233023025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	33.99872	-118.4175	Plan check for a new fire alarm system. Project site is an existing apartment building; building is not a high-rise. System consists of (1) FACP, (1) FSA, and (90) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15463	19041-10000-31143	19030 W TRIBUNE ST	91326	12	207B121   166	2718014006	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.26654	-118.54742	[EPLAN]PLAN CHECK FOR 2 ESS CONNECTED TO EXISTING PV SYSTEM EQUIPMENT - TESLA POWERWALL WITH GATEWAY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15464	17041-30000-09841	1345 S LA BREA AVE	90019	10	129B181   827	5070002008	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Issued	05/11/2017 12:00:00 AM	ADDRESS	34.04887	-118.34454	Plan check for power and Title 24.  T.I. to dental clinic in existing commercial building.  New 250 amp panel with new lighting and receptacle loads.  Total area = 1,309 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15465	15041-30000-42241	19159 W WELLS DR	91356	3	171B121   339	2163009018	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			Corrections Issued	01/07/2016 12:00:00 AM	ADDRESS	34.16481	-118.5507	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 15.2 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15466	19041-30001-19968	10960 W WILSHIRE BLVD #800	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.058	-118.44597	06/04/2019 Plan check for Title 24 only. Project site is an existing tenant suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 8,343 sq. ft.Note: Building permit has been issued under 19016-10000-15230*****Original Work Description*****EXISTING TENANT IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15467	14041-20000-33970	5645 N VALLEY CIRCLE BLVD	91367	3	174B089   313	2046015021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.17345	-118.64795	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 10kW (5+5). Ungrounded system. Using 300W power optimizers.44  255W pv modules across 4 strings (inv1 - 11+11; inv2 - 11+11).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15468	18041-20000-25766	980 E 42ND PL	90011	9	114A209   182	5115018018	R2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2286.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.00654	-118.25844	Plan check for addition of PV roof mounted  to existing PV system. New PV system size: 5.0kW with new PV modules of 8 and 1 inverter(5.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15469	19041-10000-11215	17081 W DEVONSHIRE ST BLDG B	91325	12	204B133    79	2695020030	[Q]C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	01/12/2022 12:00:00 AM	ADDRESS	34.2577	-118.50558	(1 SET OF PLANS WITH 3 APPLICATIONS) 2 OF 3-FULL PLAN CHECK FOR NEW BLDG B  LOCKER ROOM BLDG SERVED FROM BUILDING C ELECTRICAL SYSTEM. REFFER TO THE PERMIT NUMBERS BELOW. B-A# 19010-10000-01179E-A# 19041-10000-11217B-B# 19010-10000-01180E-B# 19041-10000-11215B-C# 19010-10000-01182E-C# 19041-10000-11221	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15470	13041-10000-33150	8118 N JUMILLA AVE	91306	3	189B117   130	2106014018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Expired	06/14/2016 12:00:00 AM	ADDRESS	34.21736	-118.56324	PV1, Install 9 kw DC roof-mounted solar array, interconnect with the service panel.(2)Transformerless inverter(s):Solaredge SE3000A-US and solaredge SE6000A-US. (36)modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15471	11041-10001-00284	615 W CHILDS WAY	90089	8	118-5A201  27	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	34.0191	-118.28214	Basement of USC lighting , power and title 24. plan chech / customer request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15472	16041-20000-09545	5830 N RESEDA BLVD	91356	3	174B125    23	2157005001	R3-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	10/05/2016 12:00:00 AM	ADDRESS	34.17723	-118.53581	Plan check for a PV2 roof-mounted PV system. System size 15 kWac and consists of (2) inverters, (55) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15473	17041-20000-10414	6600 N TOPANGA CANYON BLVD FC7	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	T. I. TO (E) RESTAURANT.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15474	17041-20000-01919	9721 N DONNA AVE	91324	12	201B121   363	2762032023	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.24761	-118.54766	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (36) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15475	14041-20000-11617	6345 N VARIEL AVE	91367	3	180B105    66	2149001032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.18643	-118.5936	Removal of existing generator and transfer switches.  Installation of new 250 kW diesel generator, three transfer switches, and twi panelboards.  All branch circuit loads are existing and relocate to new panels.  No change in lighting.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15476	17041-10000-16662	8500 W BEVERLY BLVD 629	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	12/15/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	"PC FOR TI  ""ZARA"" RETAIL POWER AND ENERGY. TOTAL CONNECTED LOAD >400A.TOTAL AFFECTED AREA 26841 SQ.FT. SCOPE INCLUDES NEW SWITCH BOARDS, PANELS AND CIRCUITS.BL#17016-1000-12851"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15477	10041-10000-14082	400 W PICO BLVD	90015	14	126A207   194	5134017006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			Reviewed by Supervisor	07/30/2010 12:00:00 AM	ADDRESS	34.03884	-118.26465	CHANGE OF OCCUPANCY. -FROM MANUFACTURING TO AN ATHLETIC CLUB ;TI IN THE BUILDING. NEW SERVICE, PANEL, CIRCUITS, ETC. PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15478	17041-10000-37507	700 W 7TH ST U240	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	09/26/2018 12:00:00 AM		Issued	09/26/2018 12:00:00 AM	ADDRESS	34.04797	-118.25815	Ti in an existing movie theater, plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15479	15041-20000-31729	11776 N ENCINO AVE	91344	12	213B129    38	2607012011	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Expired	11/01/2017 12:00:00 AM	ADDRESS	34.28417	-118.51526	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (57) modules, (1) load center, and (2) combiner boxes.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15480	18041-10000-34563	523 W 6TH ST 2nd Flr	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC FOR ENERGY  ONLY, T-24. SCOPE OF WORK INCLUDES NEW CORRIDOR LIGHTING ON THE 2ND FLOOR IN A HIGH RISE BUILDING. TOTAL SQ. FT. 3825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15481	18041-20003-19629	8201 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Issued	02/20/2019 12:00:00 AM	ADDRESS	34.21793	-118.6063	Revisions to approved set, delta-21 changes.  Addition of 75 kVA XFMR and subpanel BP2.  Miscellaneous power, lighting, and SLD changes to reflect field conditions.  Approval for clouded changes only.  (((12-14-2018 Changes to an approved set of plans, Changes include addition sump pump and circuit reconfigured. All Changes has been clouded.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15482	15041-10000-16734	5434 W 77TH ST	90045	11	099B173   335	4127015017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	33.9678	-118.37576	PV1 ROOF MOUNTED SYSTEM, 27 MODULES AND 1 INVERTER 6K. TOTAL SIZE 7.02 (27) KYOCERA # KU2606XPA (1) ABB #PV1-6000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15483	19041-10000-15397	4436 N LANKERSHIM BLVD	91602	4	165B177   199	2423005002	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.15147	-118.36629	Remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15484	16041-10000-29729	21300 W VICTORY BLVD #505	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.18813	-118.59618	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE FOR SUITE#505. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 1250 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15485	15041-10000-22333	9716 N PINE ORCHARD ST	91331	7	201B161   969	2624013***	(T)(Q)RD5-1, RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	PIN	34.24581968	-118.41014321	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15486	16041-20000-20549	7051 N VAN NOORD AVE	91605	2	183B161   311	2327018009	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.19903	-118.41507	Plan check for PV roof mounted system. System size: 6.0kW with 28 modules an 1 inverter(6.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15487	14041-20000-30432	13441 W CORNELIUS ST	91331	7	213B157   572	2523022013	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.27849	-118.42554	PV1Install a roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 3.655kW.17 M215 EnPhase microinverters attached to 17 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15488	13041-10003-04928	1375 N WESTERN AVE	90028	13	147A193   196	5544030055	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM			PC Approved	04/24/2015 12:00:00 AM	PIN	34.09622604	-118.30960264	"PLAN CHECK ONLY. Change to approved set by reducing the size of lighting floor plan; Lighting fixture ""B "" also changed from recessed  light to LED fixture. New scope only apply to new lighting area, exsisting light will remain as is. ((((((8/6/2014 Supl. app. for title 24 plan check only.  Previous application was for power only.  Inspector requested title 24 approvial prior to final.  Minor changes to lighting since last approved set - wattage of LED strip lighting reduced)))SERVICE UPGRADED TO 800A OVERHEAD;NO CHANGES TO THE LOAD(((((((((PC IS FOR T24 ENERGY. BUILDING ADDITION AND RENOVATION FOR AN EXISTING RESTAURANT; EXPAND RESTAURANT INTO (E) POST OFFICE (CHANGE OF USE FROM POST OFFICE TO RESTAURANT)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15489	16041-10000-24378	2545 E 24TH ST	90058	14	117A219    30	5168018005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.01644	-118.22597	Remove HID fuxtures abd replace with new LED fixtures. PC for T-24 only. Total area: 12,512 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15490	19041-10000-48305	5142 N TUJUNGA AVE	91601	2	171B173   726	2353002030	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM			PC Info Complete	11/21/2019 12:00:00 AM	ADDRESS	34.16425	-118.37883	T-24 PLAN CHECK FOR A TI TO BATHROOM AREA OF RECREATIONAL FACILITY. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 655 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15491	19041-20000-52369	23721 W ARCHWOOD ST	91307	12	180B093   229	2034010022	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Issued	12/18/2019 12:00:00 AM	ADDRESS	34.19168	-118.64351	Plan check for PV roof mounted system, PV system size: 11.6KW DC, 11.4KW AC with 29 PV Modules  and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15492	19041-10000-01068	12979 W ARROYO ST	91340	7	216B161    28	2514002075	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.29191	-118.41593	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15493	11041-10001-21195	10000 W PICO BLVD CLUBHOUSE	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	04/25/2012 12:00:00 AM	ADDRESS	34.05211	-118.40654	Plan check Delta 2 revision to approved plans. Changes consist of lighting, kitchen loads, relocate panel, and circuits. CLUBHOUSE RENOVATION @ THE HILLCREST COUNTRY CLUB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15494	18041-10001-23233	16814 W CALLE BELLEVISTA	90272	11	138B121    26	4431038022	(Q)RD3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.07771	-118.54942	Supplemental for fee expedite - plan check for roof mounted pv system for 13.44kva system using AC modules (X22-360-D-AC) with 42 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15495	15041-10000-24481	18601 W SHERMAN WAY G&H	91335	3	183B121  1183	2118027012	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.20128	-118.53897	PC AT THE COUNTER. ENERGY ONLY FOR T-24. THE SCOPE OF WORK INCLUDES LIGHTING, FIXTURE REPAIRMENTS FROM A SINGLE STORY COMMERCIAL BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15496	13041-20002-00437	21650 W OXNARD ST 12th Floor	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Changes to switching. NO changes to load. Optional standby lighting. Plan check request per inspector. Plan check for T-24 and emergency lighting. Commercial high-rise. 12th Floor. 19359sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15497	13041-10000-14127	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.24143	-118.56249	Plan check power and energy for TI existing 2-story office building includes industrial area and associated labs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15498	13041-10003-35796	2595 S HOOVER ST	90007	8	123A201    42	5055022034	C4-1VL-O, QC1.5-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	10/28/2016 12:00:00 AM	ADDRESS	34.03206	-118.28429	"10/21/16Changes to an approved set of plans. All changes are clouded under delta 3. Changes include relocating panelboards from main distribution board from ""MSA"" to ""MSB"", changes in fault current values due to relocated panels, and revisions to voltage drop for feeders. modification was filed for EGC sizes"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15499	15041-20000-36355	19645 W SHERMAN WAY BLDG 6	91335	3	183B117     7	2116001090	C2-1VL, R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.20129	-118.56157	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (24) MODULES-CANADIAN SOLAR CS6P255P(1) INVERTERS-SUNNY BOY SA SB6000US-12(1) 125 SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15500	15041-10000-27177	7221 N CLYBOURN AVE	91352	2	183B177    28	2410021008	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.20194	-118.36251	new fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15501	17041-10000-35821	78 E MARKET ST	90291	11	108A143   433	4226008011	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM			PC Approved	10/05/2017 12:00:00 AM	ADDRESS	33.98813	-118.47286	CHANGE OF USE FROM MEDICAL OFFICE BUILDING TO RETAIL AND ADDITION PLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15502	19041-10000-24471	1392 W HILL DR	90041	14	163-5A227  45	5691007012	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.144	-118.19505	(ePlan) PV1 Roof Mounted Photovoltaic System of 14 Canadian Solar 310 watt modules with 1 SolarEdge 3.8 kw inverter. System size is 4.34KWdc and 3.6KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15503	16041-10000-29245	9111 N CORBIN AVE	91324	12	198B117   206	2761001074	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.23591	-118.56269	Full Plan check. Change of use for existing two story bank building to an outpatient medical clinic. Service is being upgraded from 800 amps to 1200 A 3phase 4wire 120/208V. Adding new lighting and power. Total sqft = 16,679.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15504	17041-10001-03908	10250 W CONSTELLATION BLVD 7th floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/09/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGED NOTED DELTA 3. T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15505	13041-20000-07705	3717 S GRAND AVE 2ND FLOOR	90007	9	117A203    57	5122025006	[Q]C2-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.01615	-118.27889	Subdivide an existing area on the 2nd floor of a low-rise building.  NOT a Place of Assembly (less than 99 occupants) per applicant.  Load is less than 400 amps.  Less than 50% of change to existing lighting - (Exempt from Sec.146) - SUBJECT TO FIELD INSPECTION.  PLAN CHECK ONLY for  Lighting Controls and Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15506	13041-10001-24097	2920-2930 W ROWENA AVE BUILDING 2	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.10823	-118.26884	CHANGES MADE TO PREVIOUSLY APPROVED SET.A) ADDITION OF PV TO EACH RESIDENTIAL UNITB) REMOVE LIGHT FROM GARAGEC) ADDITIONAL J-BOXES IN RESIDENTIAL UNITS FOR FANS, LIGHTS, ETC.D) REMOVE LIGHT (FL) AND REPLACE WITH INCANDESCENT WITH DIMMER IN HALLWAYS(((NEW BUILDING. APARTMENT.  1 OF 6 TOTAL UNITS. BUILDING 2. NEW 400 AMP SERVICE.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15507	12041-10000-10166	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Change to lighting at ticket counter and for artwork display at Terminal #3 at LAX.  (Ticketing Area).  Load is 42A and occupancy load is 98, per applicant.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15508	13041-20002-00114	13833 W VENTURA BLVD # 105	91423	4	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.1487	-118.43426	Full plan check. First time tenant. Plan check for energy on 13041-20001-00114. Permit on 13041-20000-00894.  Changes to approved set of plans. Plan check for energy only. 602sqft. Suite #105T-24 lighting plan check for new beauty salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15509	16041-10002-31835	1326 W ANAHEIM ST	90744	15	030B201   251	7416002003	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	33.77893	-118.27909	PC FOR POWER SYSTEM INSTALLED IN METHANE ZONE. NEW UNDERGROUND PULL SECTION WITH SEAL OFF. POWER ONLY FOR COFFEE SHOP. T24 APPROVED UNDER MASTER APP. PERMIT FOR BUILD OUT SHALL BE COVERED UNDER THIS APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15510	11041-10002-07839	8039 S VERMONT AVE	90044	8	099B197   966	6033021018	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	33.96567	-118.292	Additional devices added to previously approved plans.  See delta 5 modifications.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15511	15041-20001-20557	20458 W RUNNYMEDE ST	91306	3	186B109   571	2114009035	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.20579	-118.57927	Expedited per customer request.PV1. Install roof mounted PV system sized 15.2 kW. Interconnected with main service panel(59) Kyocera KU2656 modules(2) Fronius Primo 7.6 Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15512	18041-10001-16606	1156 S CARMELINA AVE	90049	11	126B145   394	4264020003	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.04246	-118.47091	PLAN CHECK FOR CHANGES TO STANDARD PLAN  - CHANGES INCLUDE ADDING A NEW SOLAR MODULE TO SYSTEM. NO OTHER CHANGES ARE INCLUDED  Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15513	19041-20000-00187	17331 W TRAMONTO DR	90272	11	126B117   728	4416003057	RD2-1, RE9-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	01/08/2021 12:00:00 AM	ADDRESS	34.04152	-118.55501	Plan check for Title 24 only for Guardhouse kiosk. Total area: 117 sq ft. B#17010-10000-02906	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15514	16041-30000-25809	601 S FIGUEROA ST 36th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is the 36th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,720 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15515	13041-10001-22875	4550 W PICO BLVD C1-305	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM			PC Approved	11/04/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	"power PLAN CHECK ONLY.  FIRST TIME TENANT. 1100 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED under original application. Stuff installed: 30kva between panel B at 277/480V and panel A 120/208V. changes on the plans: FLOOR all lights on TC except for emergency. loads changed to match # receptacles, sign load shifted to one of the sign lighting circuits, and show window load modified. SLD: 3"" conduit from MSP to B with a #1 EGC. #10 EGC added to match panel schedule between B and transformer. 1.5"" conduit from transformer to A."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15516	12041-20000-17394	1810 S SELBY AVE 1-4	90025	5	129B153   419	4321004007	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			07/25/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.0504	-118.43313	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15517	09041-10003-05908	1460 N VINE ST	90028	13	147A189    91	5546025015	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM			PC Approved	05/24/2010 12:00:00 AM	ADDRESS	34.09734	-118.32646	DELTA 7 REVISIONS ; PANEL B IS RECONNECTED TO BE THRU-LUG FEED ; LOAD SUMMARY WAS REVISE DTO SHOW NEW SERVICE LOAD; CHANGES TO LIGHTING PLAN WITH REVISIONS TO TITLE 24 COMPLIANCE FORMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15518	15041-20000-21271	515 S FLOWER ST 52nd Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.05134	-118.25661	Title 24 plan check only.  Total area = 16,190 sq. ft.  Core and shell for 52nd floor of existing highrise building.  Space was previously used as office space.  New lighting and recepticles (<400 A load).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15519	19041-10000-40309	970 W 190TH ST #440	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	33.85812	-118.29302	Energy plan check for an office T.I located on the 4th floor of a high rise building. Scope includes new lighting  with a total lighting area of 2,568 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15520	10041-20000-23564	249 N JUANITA AVE	90004	13	138B197   398	5501010033	C2-1	Central	Wilshire	Rampart Village	YES	2111.10	Electrical	Electrical	Apartment			11/24/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	03/11/2011 12:00:00 AM	ADDRESS	34.07585	-118.29065	upgrade service to 600 A and new meters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15521	19041-10000-52805	850 N MISSION ROAD	90033	14	132A221   112	5410009913	M1-2D-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	04/20/2022 12:00:00 AM		Permit Finaled	10/27/2023 12:00:00 AM	ADDRESS	34.05786	-118.21756	INSTALLING 2 @ 50HP CARBON SCRUBBERS, TRANSFORMER, PANELS AND OTHER LOADS IN HAZARDOUS, CLASS I - DIVISION 2 AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15522	17041-20000-23937	6320 N BECK AVE	91606	2	177B169    39	2335025013	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Apartment			07/17/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.18546	-118.38328	new two story apartment building 800 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15523	18041-30000-38478	18815 W SHERMAN WAY	91335	3	183B121   109	2118025005	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.20128	-118.54323	Plan check for power and energy for renovation of (E) car wash.  New 800A 480Y/277V 3ph/4w service. Building permit under 18016-30000-30845.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15524	18041-10000-38677	1156 S CARMELINA AVE	90049	11	126B145   394	4264020003	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.04246	-118.47091	NEW ROOF MOUNTED 6.0KW PV SYSTEM WITH 20 PV MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15525	14041-10000-14202	12045 W KESWICK ST	91605	6	189B165  1087	2317001010	(T)(Q)R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	Apartment			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.21041	-118.3962	NEW FIRE ALARM SYSTEM FOR 4 STORY APARTMENT BUILDING. 98 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15526	13041-10000-36145	7925 S NAYLOR AVE	90045	11	099B165   674	4107001012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	33.96624	-118.39547	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 200A MAIN IN A 1-STORY HOME. non-standard plan. SYSTEM SIZE IS 4.25 kW DC. (17)power  optimizers:Solaredge Op250-LV-MC4SM-2NA-Z   (17)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15527	19041-20000-25872	13269 W SEVILLANA WAY ped	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Closed	03/05/2020 12:00:00 AM	ADDRESS	34.3153	-118.42262	energy plan check for outdoor lighting to small lot subdivision.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15528	11041-10000-07171	4480 N KESTER AVE	91403	4	166-5A149  40	2276003***	C2-1L, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.04	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM			PC Info Complete	04/15/2011 12:00:00 AM	ADDRESS	34.15197	-118.45649	T.I. TO AN EXISTING OFFICE BUILDING WITH EQUIPMENT ROOMS.  T-24 LIGHTING ONLY, OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15529	13041-10000-35053	727 E PICO BLVD # 1	90021	14	123A211    55	5132012059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.03248	-118.25306	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 629 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15530	19041-10000-00147	2830 W PICO BLVD	90006	10	129B193  1294	5075010007	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	08/04/2021 12:00:00 AM	ADDRESS	34.04705	-118.30137	ENERGY LAN CHECK FOR  A CHANGE OF USE FROM SINGLE FAMILY DWELLING TO OFFICE; SCOPE INCLUDE NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 1005-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15531	16041-30001-08988	6014 N EL CANON AVE	91367	3	177B089   549	2045004013	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.18015	-118.65333	Expedite fees only.              Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10.14 KW.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15532	15041-20001-06153	14150 W VAN NUYS BLVD #101	91331	6	201B153    32	2645021001	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/03/2015 12:00:00 AM	ADDRESS	34.25162	-118.4416	Plan check for energy only. Using 2008 Title-24 standards due to building permit being submitted prior to July 1st, 2014. T.I. and change of use for existing unit to yogurt shop, new lighting system for space. 427sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15533	16041-10000-26158	1731 N BRONSON AVE	90028	13	148-5A191 119	5545003015	C4-1-SN, R4-2	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Apartment			07/25/2016 12:00:00 AM			PC Info Complete	03/07/2017 12:00:00 AM	ADDRESS	34.10259	-118.31813	Plan check for power and energy on a new construction with two new 2000 A service for 86 unit apartment with 91,997 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15534	12041-10001-19473	3515 W WILSHIRE BLVD Floors1 &2	90010	10	132B193    16	5502032017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.0619	-118.30094	Small revisions to permitted set of plans-added 11KVA load revised lighting in trhe bar/lounge area)))))))))))MAJOR TI IN AN EXISTING HIGH RISE HOTE;  PLAN CHECK FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15535	14041-20001-08387	10637 N SYLVIA AVE	91326	12	207B117   282	2728003022	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.26375	-118.5523	fee for experdite onlyPV1.  Roofmounted PV system,  9.5kw with optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15536	08041-10001-13124	1515 S PACIFIC AVE	90291	11	106-5A143   8	4226008021	C2-1-CA	West Los Angeles	Venice	Grass Roots Venice		2735.02	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	33.98785	-118.47266	Electrical service upgrade. New 120/240V 3ph 4w delta 800A service. Methane zone location but no underground work is done.  EPC: Power.(((((( changes made to previously approved set., change of fuses to breakers, and addition of branch ckts.)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15537	13041-10000-16324	11929 W COURTLEIGH DR	90066	11	111B157  1103	4233018006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			06/20/2013 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	33.99687	-118.41943	New 4-story 22-unit apartment building.  Power and energy plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15538	16041-20000-09549	16915 W NAPA ST	91343	12	195B133   507	2689018030	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.2268	-118.50174	PV2. ROOFMOUNTED SOLAR SYSTEM.  TOTAL SYSTEM SIZE: 364 KW.   TWO BUILDING CONNECTED AS ONE FEED IN TARRIF SYSTEM.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15539	19041-10000-09382	9361 N WHITE OAK AVE	91325	12	198B129   154	2766002003	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.24067	-118.52024	PC for PV system. system includes 30 modules (hanwa-q-cell) w/solaredge optimizers p320. 1 central inverter (solaredge se6000h). system size is 9.150KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15540	19041-10000-16626	1 S LMU DR BUILDING B	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	03/11/2021 12:00:00 AM	ADDRESS	33.96577	-118.42406	Full plan check for Power and energy for New construction of 4-story Type V-A  dormitory with partial basement.   It is comprised of communal amenity spaces, one- and two-bed dorm rooms, gang bathrooms, faculty apartments, and housing offices.  (Building B). service is 4.6KV, 600A. 4wire, 3PH. Scope of work area 87,635SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15541	15041-10001-31040	10114 S COMPTON AVE	90002	15	091-5A213 215	6048013042	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	33.94476	-118.24606	T-24, PC FOR OUTDOOR LIGHTING ONLY,  INTERIOR T-24 IS ON MASTER PC# 15041-10001-31040.  (((T-24. PC FOR ENRGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (2 CLASSROOMS ADDED TO A CONVENT). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 1526 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15542	15041-10001-31376	216 N GRAND AVE	90731	15	018B197   820	7448032026	R2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Approved	01/04/2016 12:00:00 AM	ADDRESS	33.74455	-118.28995	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL NEW 3.71 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(14) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15543	13041-10000-28785	19557 W GILMORE ST	91335	3	180B117   774	2132013017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.18763	-118.55994	PV1, ROOF-MOUNTED 5KW PHOTOVOLTAIC SYSTEM IN A SINGLE STORY HOME. INTERCONNECTING WITH (E) 100A MAIN SERVICE. SYSTEM IS XFORMERLESS, WITH (20) MODULES: TRINA SOLAR #TSM-250PA05.18(1) SOLAREDGE #SE3800A-US(20) SOLAREDGE OPTIMIZERS: POWERBOX, 250W, #OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15544	19041-10000-43535	720 W WASHINGTON BLVD	90015	1	124-5A203 127	5124034005	C2-1-O-HPOZ-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	09/11/2020 12:00:00 AM		Permit Finaled	03/06/2023 12:00:00 AM	ADDRESS	34.03555	-118.2752	PLAN CHECK FOR METHANE SYSTEM CONSISTING OF 1 PANEL, 1 POWER SUPPLY, AND 61 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15545	16041-10000-08492	176 S CITRUS AVE	90036	5	138B185   426	5513014016	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.0714	-118.33954	PV1 SFD TOTAL SYSTEM SIZE 3.8KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15546	18041-10000-17383	8956 N VANALDEN AVE	91324	12	195B121   110	2784001901	OS-1XL	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			Corrections Issued	05/10/2018 12:00:00 AM	ADDRESS	34.23241	-118.54915	PLAN CHECK FOR T24 ONLY FOR OUTDOOR PATHWAY LIGHTING FOR A NEW WATER RESTORATION AREA  AND STORM DRAIN IMPROVEMENTS. TOTAL AREA: 19,141 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15547	17041-20000-41339	1413 E 15TH ST	90021	14	121-5A213 341	5130012038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.02536	-118.24477	service upgrade 800 amp.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15548	19041-20001-52350	11625 W OLYMPIC BLVD	90064	11	123B149   326	4260007028	(T)(Q)C2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	06/26/2020 12:00:00 AM	ADDRESS	34.0352	-118.4466	PV3.  Install 162 KW DC/146.96 AC CEC roof mounted PV system.  (405) modules with (4) 33.3 kW inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15549	15041-20000-00884	5329 N MECCA AVE	91356	3	171B125   108	2161016031	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.1681	-118.53769	PV1. Install roof mounted PV system sized 7.92 kW. Interconnected with main service pannel. (33) SolarWorld plus SW-280 Mono Modules(33) Enphase Energy M250 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15550	19041-10000-00687	11150 W SANTA MONICA BLVD 3RD FLR.	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI of existing public restrooms and recption areas/corridor of 3rd floor.     Install new lights. T-24 energy only. Building Permit: 18016-10000-40512	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15551	18041-10000-00983	1212 E PALMETTO ST 2ND FL	90013	14	126A215   160	5164001902	PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.03997	-118.23549	OFFICE TENANT IMPROVEMENT: ENCLOSE 1200 SF OF WAREHOUSE AREA AND CONVERT TO OPEN OFFICE.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15552	17041-10000-24114	360 E 2ND ST 2ND FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC FOR OFFICE TI. LIGHTING UPGRADES. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15553	16041-20001-27249	18771 W WILLOWTREE LANE	91326	12	207B121   529	2728029072	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM			PC Approved	08/23/2016 12:00:00 AM	ADDRESS	34.26304	-118.54197	EXPEDITE PER APPLICANT REQUESTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED10.2KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15554	11041-10000-22812	971 N YALE ST	90012	1	136-5A215 182	5414002010	C2-2D-O	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.06681	-118.23916	Fire alarm system for a new addition to a church.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15555	11041-10000-23462	12301 W WILSHIRE BLVD STE 150	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM			PC Info Complete	01/13/2012 12:00:00 AM	PIN	34.04277409	-118.46969044	TENANT IMPROVEMENT IN SUITE 150 ( OPUS BANK )PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15556	12041-20000-19454	3415 S SEPULVEDA BLVD 1100	90034	5	117B157    16	4251015007	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM			PC Approved	08/17/2012 12:00:00 AM	ADDRESS	34.02055	-118.42347	T.I. to a high rise building on the 11th floor, suite #1100.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15557	14041-10000-29713	6483 S STANFORD AVE	90001	9	105B205  1118	6007018021	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	33.98093	-118.26311	Service upgrade for existing industrial space.  New 4,000 A service (previously 1,600 A) with new main distribution switchboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15558	16041-10000-16611	17150 W VENTURA BLVD	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.16032	-118.50749	FULL PLAN CHECK FOR POWER AND ENERGY. TI TO EXISTING RETAIL(PET SMART) BUILDING WITH AN EXISTING 1000AMP SERVICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQUARE FOOTAGE 12549 SQFT. PLAN CHECKER SHOULD CHECK PREFABRICATED POWERPLUS EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15559	11041-10000-06060	3641 S HOLDREGE AVE SUITE# C	90016	10	117B173    96	4204008070	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.01958	-118.37848	TI in an existing office building. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15560	13041-20000-12568	1000 E 45TH ST	90011	9	112-5A209 145	5108026005	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.0027	-118.25807	PV1 PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. USING ENPHASE MICRO INVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 1.7 KW. USING 8 MODULES. ROOF MOUNTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15561	18041-10001-29135	10866 W WILSHIRE BLVD #820	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.05907	-118.442	This is plan check only for T24, permit has been obtained on 18041-40000-29135. (B# 18016-10000-23096)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15562	12041-10000-02154	8500 W BEVERLY BLVD # 650	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/30/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) RETAIL SPACE TO SELL PREPACKAGED FOOD (NO COOKING AND NO SITTING ON THE PREMESIS): PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15563	17041-20001-29414	3819 E SAN RAFAEL AVE	90065	1	148-5A221 103	5464014002	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.10117	-118.2184	expeditepv1install roof mounted pv system sized 7.6kw  interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15564	19041-20000-24898	17257 W VENTURA BLVD	91316	5	171B133   658	2258012026	(Q)P-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.16091	-118.50901	ti to an exising commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15565	12041-10000-05848	13603 W MARINA POINTE DR	90292	11	105B153    74	4229003066	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Apartment			03/14/2012 12:00:00 AM			PC Approved	04/11/2012 12:00:00 AM	ADDRESS	33.98559	-118.44433	This appartment, four story , title 24 and emergency lighting for ground level, used for community center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15566	15041-20000-35219	23732 W VANOWEN ST	91307	12	180B093    71	2034001013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.19311	-118.64378	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 25 MODULES. USING STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15567	11041-10000-06733	1324 S NORMANDIE AVE	90006	1	129B197  1144	5075009021	C2-1VL, [Q]R4-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Public Safety Only			04/05/2011 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.04644	-118.30011	NEW FIRE WARNING SYSTEM IN A COMMUNITY CENTER ( 2 FLOORS )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15568	18041-20000-15839	20639 W CHESTNUT CIR (#270)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	12/29/2018 12:00:00 AM	ADDRESS	34.29342	-118.58381	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15569	19041-10000-02250	504 S HARBOR BLVD	90731	15	015B201   221	7440030***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	06/17/2020 12:00:00 AM		Permit Finaled	11/16/2021 12:00:00 AM	ADDRESS	33.74047	-118.27853	OUTDOOR LIGHTING. INSTALL 84 LIGTHS & SECURITY DEVICES. TITLE-24 ENRGY. 96,501 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15570	19041-20000-38555	13523 W HARTLAND ST	91405	2	183B157   844	2328012037	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.19501	-118.42767	Plan check for PV roof mounted system, PV system size: 11.62KW DC, 10.58KW AC with 28 AC Modules and 2 sub-panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15571	16041-10000-34962	11711 W NATIONAL BLVD	90064	11	120B153  1058	4257011025	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	04/01/2017 12:00:00 AM	ADDRESS	34.02262	-118.43924	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1646 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15572	14041-20001-07577	11375 N STRANWOOD AVE	91344	12	213B145   194	2662003020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.27748	-118.47224	Remove sub-pannel under delta 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15573	14041-10000-19578	5535 W HOLLYWOOD BLVD	90028	13	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.10188	-118.31042	CHANGE OF USE FROM RETAIL TO DENATL OFFICE ; 1400 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15574	13041-10000-16337	4550 W PICO BLVD C322	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	06/21/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	Retail TI for new clothing store in shopping center.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15575	16041-10000-33855	2970 W OLYMPIC BLVD 201-203	90006	10	129B197   249	5078017023	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.05241	-118.29951	Plan check for power and energy for Medical Dental office T.I. in existing space. Total area: 3,150 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15576	14041-10001-23570	225 S OLIVE ST	90012	14	130-5A211   9	5149010***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Apartment			09/29/2017 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	ADDRESS	34.05317	-118.24961	Change to approved set by adding door bell for all units and modifying the ground and third floor. All changes under delta-2 only. No new ckts added.(((Plan check for energy (indoor and outdoor) on an alteration for highrise building, work applies to each floor corridor  in the whole building. Additional work  apply to ground and third floor. total working area is 27119 SQ feet.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15577	15041-10000-12026	550 S HOPE ST #1835	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	Energy plan check for an office TI located in suit #1835 of a high rise building; scope includes installing new lighting and receptacle. Total area 951 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15578	17041-30000-37252	3675 S DUNN DR	90034	5	120B165  1528	4313007054	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Closed	04/25/2019 12:00:00 AM	ADDRESS	34.02542	-118.40178	Plan check for new fire alarm system 18 units appartment. Total fire alarm devices: 107 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15579	18041-20001-23703	1031 S BROADWAY	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM			PC Approved	05/13/2019 12:00:00 AM	ADDRESS	34.04041	-118.2583	5/13/19changes to an approved set of plans.  changes to reflect field conditions.  changes noted delta B only.((((PC FOR NEW ELECTRICAL SERVICE IN EXISTING HIGH RISE  BUILDING FOR INTERIOR CORE AND SHELL REMODEL POWER AND ENERGY. SCOPE INCLUDES MAIN SERVICE  AT 4000A 277/480V.SOCPE INCLUDES NEW PANELS, EQUIPMENT AND CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 44,097 SQ.FT))))  B# 16014-10000-05854	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15580	19041-20000-34782	12517 W SHERMAN WAY	91605	2	183B161    21	2324003010	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.20135	-118.406	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 9.28 KW DC/ 7.6KW AC. SCOPE OF WORK CONSISTS OF (29) PV MODULES WITH POWER OPTIMIZERS AND A 7.6 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15581	13041-10000-35694	2201 S LONG BEACH AVE WEST	90011	9	117A213    28	5118023001	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.01644	-118.24338	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 9688 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15582	13041-10000-16088	3075 W WILSHIRE BLVD BSMNT&1ST	90010	10	135B197  1198	5077009005	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20, 2122.04	Electrical	Electrical	Apartment			06/18/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.06197	-118.28885	IN AN EXISTING APARTMENT BUILDING; ALTERATIONS ARE MADE TO THE COMMON AREAS IN THE BASEMENT AND ON THE FIRST FLOOR. NEW LOADS ARE LESS THAN 400A; PLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15583	16041-30000-39924	10909 W HARTSOOK ST	91601	2	171B173   761	2419001027	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Apartment			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.16365	-118.3685	Plan check for new fire alarm system for new appartment building 27 units. Total fire alarm devices: 84 and 1FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15584	11041-20000-12895	846 N CAHUENGA BLVD	90038	4	141B185    43	5533029002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	09/30/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.08662	-118.32862	Red Studios Hollywood.  Adding new distribution board and new loads.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15585	13041-10000-35953	9200 N OAKDALE AVE #STE 600	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.23811	-118.56674	PLAN CHECK FOR T24 ENERGY ONLY.  NEW CONNECTED LOAD <400 AMPS. OFFICES. NO CHANGE IN OCCUPANCY. 9 STORY BUILDING. HIGHRISE. WORK IN 6TH FLOOR. SUITE 600. 10738 SQFT. EMERGENCY LIGHTING.TENANT IMPROVEMENT - DEMOLITION, PARTITION AND CEILING (9946 S.F)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15586	18041-10000-33144	6550 W YUCCA ST	90028	13	148-5A187  21	5547008408	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.10327	-118.33273	"Replacing an existing damaged 800 Amp Service ""Like to Like"" in an existing Apartment Building10 Feet from the existing service location per LADWP's Specs. Reconnect to existing 48 units. No New Load added.Note: A second 800 Amp Sevice feeding the remaining 48 uints in the building are existing to remain."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15587	18041-20000-40699	832 S PLYMOUTH BLVD	90005	4	132B189   457	5090028009	[Q]R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.0589	-118.32416	Installation of 26.4 kWh energy storage system connected to existing PV system, associated distribution, and critical load backup panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15588	18041-20000-47685	9662 N GEYSER AVE	91324	12	201B121   484	2763025004	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.24635	-118.54258	Plan check for PV roof mounted system, system system size: 13.2kW DC, 11.88kW AC CEC with 40 PV moduels and 40 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15589	10041-10000-21062	12000 S VISTA DEL MAR 1st fl	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM			PC Approved	10/22/2010 12:00:00 AM	PIN	33.92817449	-118.43220714	remodeling of officesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15590	18041-10000-00120	7614 N HAYVENHURST AVE	91406	6	186B137   381	2205010905	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20934	-118.49223	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15591	15041-20000-22433	5900 W CENTER DR 1-327	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Closed	08/12/2016 12:00:00 AM	ADDRESS	33.97559	-118.38853	Plan check for the installation of service equipment for temporary power. Work includes a 2500-amp service, (12) panels, associated loads, (1) transformer, and (1) elevator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15592	16041-20000-03321	1985 E ZONAL AVE 208AA	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	04/09/2016 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for Title 24 only for existing space USC PSC STAUFFER. Total area: 110 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15593	19041-10000-29539	1031 N ENCHANTED WAY	90272	11	132B121   443	4419003016	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM			Reviewed by Supervisor	08/14/2019 12:00:00 AM	ADDRESS	34.05557	-118.5493	INSTALLATION OF 2 ESS(TESLA POWERWALL) TO 200A SERVICE ON EXISTING SINGLE FAMILY DWELLING - MAIN PANEL LOADS HAVE BEEN RELOCATED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15594	17041-10000-38945	5750 W HOLLYWOOD BLVD	90028	13	148-5A191 160	5586035002	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	04/29/2022 12:00:00 AM	ADDRESS	34.10154	-118.31491	FULL PLAN CHECK FOR A 7 STORY MIXED USE BUILDING WITH 161 APARTMENT UNITS. BUILDING INCLUDES (2) 208/120V, 3ph,  2500AMP SERVICES FROM DWP. 7 TYPICAL UNIT LAYOUTS WITH 2 TYPICAL PANEL SCHEDULES. PLAN CHECK IN ACCORDANCE  WITH 2014 LAEC. HORIZONTAL EXIT IS PROVIED PER BUILDING PERMIT B#16010-10000-05275	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15595	19041-20000-15241	1119 W 29TH ST 1-15	90007	9	121-5A201  32	5055028020	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			04/25/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.02849	-118.28485	Renovation of (E) 15-unit apartment building.  New 600A 240/120V 1ph-3w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15596	19041-20000-04734	687 S HOBART BLVD Unit D	90005	10	132B193   184	5093006035	(T)(Q)C2-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.0605	-118.30557	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to restaurant. Total lighting area = 2,296 sq. ft.Note: Building application has been generated under 18016-20000-37076	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15597	16041-10000-30322	1621 S SOTO ST	90023	14	118-5A221  20	5169015004	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.02038	-118.22047	T24 ONLY, ENERGY PLAN CHECKING FOR SIGN LIGHTING (EXTERNALLY ILLUMINATED ). TOTAL AREA 70 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15598	19041-20000-00783	12629 N GLENOAKS BLVD	91342	7	219B153   136	2508027030	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.29953	-118.43965	T-24 FOR A TI IN RETAIL STORE. NO CHANGE OF USE. SCOPE INCLUDES NEW SUB PANEL REPLACEMENT LIKE FOR LIKE(200A), RECEPTACLES, EQUIPMENT AND LIGHTING. TOTAL AFFECTED AREA IS 6154 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15599	15041-10001-01070	12510 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.97839	-118.4121	(3/3/2015) CHANGES TO AN APPROVED SET OF PLANS.  CHANGE FROM UNDERGROUND SERVICE TO OVERHEAD SERVICE.  DELTA ONE REFLECT THE CHANGES DONE ON THE PLANS.Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps.Fire alarm variance submited. Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15600	15041-20000-11927	5698 S GOLDENEYE CT UNIT 2	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	33.9792	-118.41068	Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL BE RELAVENT  TO UNIT # 1 OF ADDRESS 5698 GOLDENEYE CORT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15601	17041-20000-46352	865 S FIGUEROA ST 23rd Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for energy only. TI to (E) office on 23rd floor (State Bar) of high rise building. New lighting (incl. emergency) - 2,425sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15602	19041-20000-12832	24052 W BESSEMER ST	91367	3	177B089   433	2045006014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM			PC Approved	04/09/2019 12:00:00 AM	ADDRESS	34.18133	-118.65127	changes to an approved set of plans.  changes to reflect field condtions.  plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15603	18041-20000-05015	743 N SEWARD ST	90038	4	141B185   348	5533037003	CM-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	34.08469	-118.33326	Plan check for power and energy. Project site is a new commercial building. Work includes a new 600-amp service and a total lighting area of 17,858 sq. ft.Note: Building application has been generated under 18010-20000-00243.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15604	19041-10001-09464	3526 W WASHINGTON BLVD	90018	10	126B189   972	5060023004	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2188.00	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM			PC Approved	10/08/2019 12:00:00 AM	ADDRESS	34.03969	-118.32342	Change to an approved set by changing 1-type of lighting fixture on the floor plan, all changes under delta-1 only.(((TI IN AN EXISTING COMMERCIAL SPACE. INSTALLING NEW LIGHTS. T-24 ENERGY ONY.TOTAL AREA: 2190 SQR FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15605	15041-20000-21697	6316 N TOPANGA CANYON BLVD B-1125	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Closed	08/21/2018 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and energy. Project scope is a first time tenant at the Westfield Village project. Total lighting area = 1,639 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15606	13041-10000-16042	9225 S AVIATION BLVD	90045	11	093B173    59	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	33.95196	-118.37721	pc for power and energy. NEW BUS WASH AND MAINTENANCE BUILDING  7211 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15607	18041-10000-47322	10333 N KEOKUK AVE	91311	12	204B113    87	2707016009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.25876	-118.57419	NEW 15.2 KW ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOME WITH 55 PV PANELS.$0 PERMIT FEES DUE TO SENATE BILL 1222, AND ASSEMBLY BILL 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15608	15041-20000-29397	9818 N AQUEDUCT AVE	91343	12	201B141   272	2671006012	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.24862	-118.4738	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, and (33) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15609	15041-10000-34674	4101 S CRENSHAW BLVD 3RD FLR	90008	8	114B185   323	5032002066	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.00994	-118.33552	PLAN CHECK FOR ENERGY ONLY FOR REMODEL 3RD FLR WALMART.  SCOPE OF WORK IN STOCK ROOM AND LAYAWAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15610	16041-10000-23366	125 W 5TH ST	90013	14	129A211   281	5149022***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.0471	-118.24893	PC for energy only. Change of use from retail to cafe shop. Installing new lighting and power. Total sqft= 994	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15611	19041-20000-07133	414 S VIRGIL AVE	90020	13	136-5A201 298	5077001033	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.06632	-118.2869	PV2.  Install 22.27 kW DC / 20.45 kW AC-CEC roof mounted grid tied PV system.  (61) modules with (2) 10 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15612	16041-10001-17389	1755 N ARGYLE AVE	90028	13	148-5A189   5	5546030029	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.1035	-118.32546	12-04-2017 Changes to an approved set of plan. Changes include remove netural wire; changes has been clouded.Plan check only. ********************Provious Work Description*****************************PC FOR POWER AND ENERGY .NEW 18-STORY 114 UNIT APARTMENT WITH GARAGE WITH NEW 480-277 V 3PH 4 WIRE 2500A  SERVICE. ALSO, ADDING NEW LOAD EQUIPMENT FOR EACH UNIT, INCLUDING 16 TYP UNITS AND TOTAL AREA 134070 SQFT. BUILDING PERMIT #15010-10000-04187	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15613	17041-10000-31559	10250 W SANTA MONICA BLVD Kiosk 9210	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Issued	09/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for power and energy on a  core and shell for future tenant on Kiosk 9210. Install one panel and its circuitry.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15614	16041-10000-06514	11401 W SANTA MONICA BLVD	90025	11	129B149   513	4261003009	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			02/24/2016 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.04602	-118.4512	PC FOR POWER AND ENERGY. NEW APARTMENT BUILDING WITH 6-STORY, 51 UNITS. TOTAL AREA 56000 SQ FT,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15615	17041-20000-23264	515 S FLOWER ST 11th floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS AND LOBBY ON THE 11th FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15616	10041-10000-07205	1743 N CAHUENGA BLVD	90028	13	148-5A187  48	5546006007	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM	04/29/2010 12:00:00 AM		Permit Finaled	05/10/2010 12:00:00 AM	ADDRESS	34.1029	-118.32971	iNSTALLING NEW FIR DEVICES AND A FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15617	17041-10000-20994	10271 W PICO BLVD	90064	5	129B161   308	4315014005	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.04886	-118.41298	FULL PC FOR POWER AND ENERGY. TI FOR A 3 STORY OFFICE SPACE. SCOPE INCLUDES A NEW 800A 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS,  AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 7620 SQ. FT. B#17016-10000-14614	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15618	14041-20000-20451	12030 N BEAUFAIT AVE	91326	12	216B125    28	2870004029	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.29169	-118.53667	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(19) TRINA SOLAR TSM255 MODULES(1) POWERONE TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15619	15041-10000-38343	3731 W STOCKER ST	90008	8	114B185   738	5032022017	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM			PC Approved	11/13/2015 12:00:00 AM	ADDRESS	34.00657	-118.33812	PC FOR ENERGY ONLY. T.I. FOR A COMMERCIAL BUILDING. TOTAL LOAD ADDED  LESS THAN 400A. TOTAL AREA 3077 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15620	17041-20000-24558	1422 N FRIES AVE	90744	15	036B205  1004	7421023004	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	33.79179	-118.26566	pv1install roof mounted pv system sized 4kw interconnected wih msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15621	10041-10000-13356	412 W HARRY BRIDGES BLVD	90744	15	027B205   425	7440006029	M3-1D	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	33.7709	-118.2663	New Truck parking lot. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15622	19041-10000-01884	16518 W CHATSWORTH ST	91344	12	207B137   449	2679001007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.26456	-118.49191	PLAN CHECK FOR A ROOF MOUNTEFD 8.640 PV SYSTEM CONSISTING OF 27 MODULES USING ENPHASE IQ7X MICRO INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15623	12041-10000-01718	1666 S GREENFIELD AVE 1-6	90025	5	129B153   588	4324030012	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			01/24/2012 12:00:00 AM	06/22/2012 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.04918	-118.44155	4-STORY 10-UNIT MULTI-FAMILY DWELLING OVER SUBTERRANEAN GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15624	18041-10001-38858	401 E 7TH ST	90014	14	127-5A211 276	5148024026	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			PC Approved	11/15/2019 12:00:00 AM	ADDRESS	34.04196	-118.24829	RE-PLAN CHECK FOR A LOST SET OF PLANS. NOTE: PERMIT FEES ARE UNDER THE MASTER APPLICATION 18041-10000-38858NEW COMMERCIAL ROOFTOP SOLAR SYSTEM CONSIST OF 124 MODULES (HANSOL HS340) AND 64 POWER OPTIMIZERS (P730) WITH 3 CENTRAL INVERTERS (2 SOLAR EDGE SE14.4KUS + 1*SOLAR EDGE SE9KUS). SCOPE INCLUDES NEW 200A LOAD CENTER.  SYSTEM SIZE IS 46.72KWdc and 37.8KWac	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15625	18041-10000-05903	8625 W 3RD ST PLAZA LEV	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	04/20/2021 12:00:00 AM	ADDRESS	34.07372	-118.38006	BRANCH CIRCUITS FOR FLOOR-MOUNTED WAY FINDING SIGNS ( LED STRIP) AT PLAZA LEVELnOTE OCCUPANCY I2.1APPLICANT ASKED FOR PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15626	16041-10000-24829	4371 E VALLEY BLVD	90032	14	135A229    71	5215014001	[Q]CM-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM			Reviewed by Supervisor	07/21/2016 12:00:00 AM	ADDRESS	34.06339	-118.19021	Change to approved set of plans.Rearranging location of solar modules.  Master application under # 16041-10000-01818((($0 final fee per senate bill 1222.PV2, rooftop solar insrallation 86.4 kW AC system(296) RENASOLA JC310M-24(6) SE14.4KUS(1) 300A subpanel no fees due to senate bill 2012)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15627	14041-20000-13569	800 W 6TH ST 5th floor	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.05011	-118.2577	TI to lobby and restroom common areas of existing commercial office highrise building.  Title 24 plan check only for changes to lighting system.  Existing permit under 14041-90000-11175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15628	16041-20001-25329	1309 W SEPULVEDA BLVD	90501	15	045B197   144	7347018094	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			09/20/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	33.81485	-118.29961	09/20/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta A. Feeders have been changed from CU to AL, as indicated on revised plan set.*****Previous Work Description*****PC FOR POWER AND ENERGY. NEW SIX STORY, 176 UNITS APARTMENT BUILDING. 6 TYPES APARTMENT WITH THE SAME PANEL TYPE. SCOPE OF LIGHTING INCLUDES OUTDOOR AND INDOOR: 150318 SQ FT.B# 15010-10000-00532	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15629	14041-20001-06289	428 N ALTA VISTA BLVD	90036	5	141B181  1385	5525026022	R2-1	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Info Complete	05/23/2014 12:00:00 AM	ADDRESS	34.07907	-118.3473	PC FOR SINGLE FAMILY DWELLING. PV1. NONSTANDARD PLAN. USING POWER OPTMIZERS. 3.8 KW AC. TRANSFORMERLESS INVERTER. PERMIT ALREADY ISSUED UNDER OROGINAL APPLICATION. THIS IS PLAN CHECK ONLY. SOLAR CLEARANCE UNDER 14041-20000-06289.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15630	17041-20000-36619	6124 W WILSHIRE BLVD	90048	5	135B177   517	5088002035	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.06283	-118.36244	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LYTE NUTRITION AND FITNESS. 1519 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15631	17041-30000-36678	16331 W CELINDA PL	91436	5	165B137   208	2284017014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.14957	-118.48939	Plan check for PV roof mounted system on SFD. Total system size:17.28 KW with 48 AC Modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15632	14041-10000-12007	3330 W CASITAS AVE	90039	13	153B209   303	5436007013	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.11719	-118.25358	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15633	17041-20000-39452	6345 N VARIEL AVE	91367	3	180B105    66	2149001032	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	03/01/2018 12:00:00 AM		Issued	03/01/2018 12:00:00 AM	ADDRESS	34.18643	-118.5936	Plan check for a PV2 roof-mounted PV system. System size is 360 kWac and consists of (15) inverters, (1,584) modules, and (5) distribution boards.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15634	19041-10000-28765	17401 W VENTURA BLVD A-25	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.16136	-118.51189	PC T-24 ONLY FOR TENANT IMPROVEMENT OF EXISTING NAIL SALON AND EXPAND TO ADJACENT RETAIL SPACE TOTAL OF 1605 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15635	13041-10000-35703	1015 S CROCKER ST #R11	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 280 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15636	12041-20000-01687	9144 N DEERING AVE	91311	12	198B105   160	2746010031	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.237	-118.59594	energy plan check bathrooms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15637	09041-10005-24226	13488 W MAXELLA AVE	90292		105B153    77	4212004014	[Q]M1-1, [T][Q]RAS4-1		Palms - Mar Vista - Del Rey	Del Rey			Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	09/05/2012 12:00:00 AM	ADDRESS	33.98592	-118.44252	DELTA 7 REVISIONS TO PERMITTED SET OF PLANS ( WORK IS UNDER CONSTRUCTION ) CHANGES ARE TO THE LIGHTING SYSTEM AND TO THE LAYOUT  OF THE APARTMENT UNITSALL CHANGES ARE CLOUDED ON THE PLANS(((((((((New 244 apartment building in methane zone.  Variance was filed to separate the the Fire Alarm plans and approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15638	14041-20000-14187	14505 W FORTUNA LANE	91402	6	198B149   635	2644030215	(T)(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.24234	-118.44837	pv1 single family dwelling. total system size 3.8 kw ac using nonstnadard plan. using transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15639	14041-20000-33153	12215 W VENTURA BLVD UNIT 104	91604	2	162B165   123	2367017006	C2-1L-RIO, P-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.1434	-118.399	Plan check for energy only. TI to existing retail restaurant space. 446sqft. Add new lights/update existing lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15640	16041-10001-10285	350 S GRAND AVE #2A	90013	14	130-5A211 204	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	PIN	34.05171748	-118.2505467	05/12/16Changes to an approved set of plans. Changes include connected emergency lights to emergency generator, not using unit equipment for emergency lights.NOTE: PERMIT PAID UNDER PCIS#16041-10000-10285((((T-24, PC FOR ENERGY ONLY. CHANGE OF USE  FROM RETAIL TO YOGA STUDIO.  TI TO AN EXISTING PORTION OF A HIGH RISE COMMERCIAL BUILDING  AT PLAZA LEVEL  SUITE  2A. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3263 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15641	17041-10000-06364	222 W 6TH ST 4th FLOOR	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	33.73887	-118.28305	TI TO OFFICE TO CREATE PARTITION. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15642	14041-10002-10037	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	change to approved set by adding more sensors and horn stroke; all changes are under delta-10new methane gas detection system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15643	11041-10000-12674	1 W CENTURY DR 38B	90067	5	132B161   720	4319017157	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.0567	-118.41497	BUILD OUT OF RESIDENTIAL UNIT #38B IN A HIGH RISE BUILDING.  FIRST TIME TENANT WITH LIGHTING UPGRADES IN ELEVATOR LOBBY.  FULL PLAN CHECK.  FIRE ALARM FOR BUILDING WAS SUBMITTED AND APPROVED UNDER 08041-10000-08801	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15644	18041-10001-24133	345 E 51ST ST	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles	Zapata-King		2293.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	33.99665	-118.26853	CHANGE OF ADDRESS - FEE $0.00 DUE TO DEPARTMENT ERROR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15645	09041-20001-09839	7338 N BALBOA BLVD	91406	6	186B133   874	2226030017	(T)(Q)RD1.5-1	South Valley	Reseda - West Van Nuys	West Van Nuys / Lake Balboa		1275.10	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.20407	-118.50092	Revision to approved plans. The revisions are on main switchboard and adding to new subpanels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15646	12041-10000-09040	8000 W SUNSET BLVD A110	90046	5	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.09783	-118.36466	"NEW ""PEI WEI ASIAN DINNER"" RESTAURANT IN AN EXISTING COMMERCIAL BUILLDING IN UNIT # A110."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15647	15041-10000-01839	428 S HEWITT ST	90013	14	127-5A215 306	5163021030	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.04271	-118.23507	Energy plan check for a change of use from a storage to a bar.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15648	15041-10000-28778	1200 W 7TH ST #440	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.05136	-118.26616	Energy plan check for an office T. I located in the 4th floor of a high rise building. Scope includes new lighting and receptacles with existing circuits for half of the floor, tenant EWDD. Total area is 2372-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15649	19041-20000-00997	20851-20857 N SHERMAN WAY	91306	3	183B109    62	2113013038	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	PIN	34.20136408	-118.5880133	Fire-damaged building and tenant improvements. Plan check for power and energy. Total area: 5250 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15650	13041-10000-12657	305 N BREED ST	90033	14	129A223   232	5175011027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00, 2044.20	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.04755	-118.20883	PLAN CHECK FOR TITLE 24 ENERGY. EMERGENCY LIGHTING IS NOT IN SCOPE OF WORK. ADDITION OF TRACK AND STRIP FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15651	11041-20000-00529	2800 W RIVERSIDE DR	90039	4	151-5A207  93	5438025011	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	03/25/2011 12:00:00 AM		Permit Finaled	11/28/2011 12:00:00 AM	ADDRESS	34.10921	-118.26198	New roof mounted P.V. system with 47.61 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15652	13041-20000-10779	806 S SANTA FE AVE	90021	14	124-5A217 356	5166003001	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.03324	-118.22984	energy plan check coffee rosting facility/restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15653	18041-10000-09351	532-536 S BROADWAY	90013	14	129A211   132	5149035004	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Issued	09/25/2018 12:00:00 AM	ADDRESS	34.04722	-118.25124	FULL PLAN CHECK FOR A EXISTING HIGH RISE BUILDING UPGRADE.  SCOPE INCLUDES A NEW 600 AMP SERVICE, NEW BACK UP GENERATOR, PANELS AND CIRCUITS WITH NEW LOAD CALCULATION. TOTAL AREA IS 23,778 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15654	12041-10000-03891	105 W CENTURY BLVD 7/11	90003	8	091-5A203  82	6053020029	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM			PC Info Complete	07/18/2012 12:00:00 AM	ADDRESS	33.94571	-118.27437	New 7-11 Store. 24 HOUR OPERATION. Installing new panels, and CKTs. EPC is for power & energy. THIS IS THE FIRST TENANT IN THIS SHOPPING CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15655	15041-10001-34756	740 S RIDGELEY DR	90036	4	132B181   133	5089005011	[Q]R4-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.06127	-118.35077	Changes to an approved set of plans. Changes include relocating main service panel and relocating sump pumps on the floor plans. Changes to reflect as built conditions. Note: Permit is paid under PCIS#15041-10000-34756	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15656	11041-10001-02353	6333 W 3RD ST # 110	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	09/14/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	Changes to permitted set of plans-service loads were decreased as as some lods went from 3ph to 1ph 2-poles.;deleted and revised luminaires; adjustem Title 24 form to reflect these changes;lighting fixture schedule and lighting control panel revised.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15657	11041-10000-10748	1900 S SEPULVEDA BLVD	90025	5	126B153   181	4323022031	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	02/12/2013 12:00:00 AM	ADDRESS	34.04447	-118.4413	Existing shell building 3 stories tall with 3 story parking garage.  Everything is new.  DWP is demo-ing existing 1000 amp service and putting in two 1000 amp services.  Applicant has submitted variance to have 2 services installed.  All wiring is new.  Everything to be considered new.  Also, applicant has submitted the architectural and demo plans for reference.  Applicant has also submitted plans for a fire alarm under a different application.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15658	17041-20000-43991	4039 N CODY ROAD	91403	4	165A147   279	2277013025	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			Reviewed by Supervisor	12/21/2017 12:00:00 AM	ADDRESS	34.14436	-118.4639	addition of (2) tesla powerwalls to an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15659	14041-10000-00632	10418 1/2 W PENROSE ST	91352	7	195B177   247	2404002016	RA-1-K	North Valley		Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.23206	-118.35781	PV1.  Install 2.592 kW AC roof-mounted PV system, interconnect with main service panel.  Microinverter standar plan.  Enphase M215.  12 modules: E&H CO LTD EHS3-250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15660	16041-20000-04884	5258 N DENNY AVE 1-7	91601	2	171B177   386	2416026012	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			02/11/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Issued	11/21/2016 12:00:00 AM	ADDRESS	34.16653	-118.36413	Plan check for energy only. New 3-story 7-unit apartment building. Check common area, parking garage, and outdoor lighting only. 5,750sqft indoor; 1,625sqft outdoor; total 7,375sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15661	16041-10000-30699	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	33.97811	-118.39245	PC FOR CORE AND SHELL. EXISTING BUILDING WITH EXISTING SERVICE. REUSING MOST DISTRIBUTION AND PROVIDING NEW CIRCUITS, LIGHTING AND SOME RECEPTACLES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15662	19041-10000-41083	1412 S LORENA ST	90023	14	118-5A225 288	5190034002	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	34.01826	-118.20681	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15663	19041-20000-36230	2501 W VERNON AVE	90008	10	111B189   128	5023031027	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	05/10/2021 12:00:00 AM	ADDRESS	34.00381	-118.32052	Plan check for Title 24 Energy only in existing space T.I. Office. Total area: 4318 sq ft. B#19016-10000-08441	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15664	17041-20000-44625	5750 W WILSHIRE BLVD 600	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	03/10/2018 12:00:00 AM	ADDRESS	34.06227	-118.3542	Plan check for energy only. TI to office/editing suite on 6th floor of high rise building. New lighting (incl. emergency) - 1,300sqft. Building permit application #17016-10000-36268.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15665	19041-10000-28982	3911 S FIGUEROA ST Cons #27	90037	9	117A201    82	5037027915	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Issued	07/26/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	PC for T24 only per inspectors request, scope of work includes new lighting and controls and equipment in a conscession stand #27. Total affected area is 1,783 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15666	16041-10000-23431	13843 W MILBANK ST	91423	4	168B153   842	2271005003	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.15313	-118.43448	$0 fee due to senate bill 1222 from 2012PV1. NEW SOLAR SYSTEM FOR AN EXISTING RESIDENTIAL ROOF-TOP. SOLAR SYSTEM INCLUDES BATTERY STORAGE SYSTEM AND AN INVERTER/CHARGER. TOTAL PV SYSTEM SIZE IS 6.45KWac.(30)MODULES-HYUNDAI HIS-S255RG(30)MICROINVERTERS-ENPHASE M215-60-2LL-S22(1)BATTERY STORAGE INVERTER-SCHNEIDER XW-5548  5500W	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15667	15041-20000-10132	2245 W YOSEMITE DR Building A	90041	14	160-5A221  43	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.13556	-118.21671	"Plan check for power  and energy only. Work being done on Building ""A"". Removal of existing multiple services and adding a new 1600A service. 3,600 sqft outdoor."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15668	15041-10000-34685	603 N ST LOUIS ST	90033	14	130-5A223 353	5175027001	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Refund in Progress	07/08/2016 12:00:00 AM	ADDRESS	34.05069	-118.21025	PV1.  Installation of 3.445 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15669	16041-10000-35003	1611 S PACIFIC AVE	90291	11	106-5A143  28	4226009022	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM			PC Approved	10/04/2016 12:00:00 AM	ADDRESS	33.98732	-118.47221	Plan check for Title 24 only for restaurant T.I. in existing building. Total area: 1,031 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15670	13041-10000-00636	2101 E PACIFIC COAST HWY Bldg 322	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.79173	-118.23549	SHELTER IN CLASSIFIED/HAZARDOUS AREA. EQUIPEMENT ON SKID TO BE TESTED BY THIRD PARTY TESTING LAB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15671	18041-10000-23288	121 W ELMYRA ST	90012	1	135A217    79	5409006014	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Issued	06/22/2018 12:00:00 AM	ADDRESS	34.06511	-118.23246	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15672	18041-20000-00409	10918 N ODESSA AVE	91344	12	210B137   825	2680009016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.26887	-118.49112	34$ permit fees due to senate bill 1222Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (2) inverters, (38) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15673	15041-20002-35651	19412 W MAYALL ST	91324	12	204B117   477	2726019024	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.25352	-118.55589	(EXPEDITE FEE)Epress Permit pulled under 15041-30000-35651. Inspector requested PC.(66) modules SUNIVA OPT 275-60-4-1B0, 280W(66) microinverters: ENPHASE M250-60-22L-S22-IG((ROOF MOUNTED GRID-TIED, STRING INVERTER SYSTEM.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15674	18041-20000-20269	12432 W FOOTHILL BLVD	91342	7	213B161   995	2527022034	[T][Q]MR1-1-CUGU, [T][Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.04	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.28515	-118.40672	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15675	14041-20000-17764	13287 N RALSTON AVE	91342	7	225B141   172	2501002027	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.31289	-118.47324	Tenant improvements for commercial cooler building for storing of produce.  New 800A distribution panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15676	14041-10000-35160	230 S SANTA FE AVE STE-R,S,T,V	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.04661	-118.2324	POWER PLAN CHECK FOR OWNER IMPROVEMENT ON (4) RETAIL SPACE IN A MIXED USE BUILDING (Separate building, electrical and mechanical permits are required for all commercial tenant space build-outs; WORKING AREA INCLUDE RETAIL  UNIT R, S, T, & V.  Inspector to verify impedance of transformer on MSD-1.REFERENCE APPLICATON # : 11041-10000-27025	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15677	12041-10000-15074	1505 S PERRINO PL	90023	14	118-5A219  10	5169015014	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			Reviewed by Supervisor	08/22/2012 12:00:00 AM	ADDRESS	34.02018	-118.22248	Plan check for 134.5KW roof mounted photovoltaic system for existing commercial building with two services. First service photovoltaic system under #12041-10000-15068. (Application 2 of 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15678	15041-20000-04144	17956 W MONTAGUE CT	91344	12	219B129   226	2601063024	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.29845	-118.52403	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15679	13041-10001-35529	341 S 6TH AVE	90291	11	111B145  1128	4240010015	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.99811	-118.47126	Expedited RSES plan check per applicant request.{{PV1, Install 7.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Fronius IG Plus A 7.5. (30) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15680	17041-30000-36215	418 1/2 N FAIRFAX AVE	90036	5	141B177  1410	5527030019	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.07883	-118.36128	Plan check for Title 24 only in existing space T.I. in restaurant. Total area: 1,700 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15681	18041-10000-00100	9533 N IRONDALE AVE	91311	12	201B109   333	2748023060	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.24358	-118.58609	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 22800 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15682	10041-10000-17322	7260 N OWENSMOUTH AVE	91303	3	186B105   909	2111019903	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.10	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	12/30/2010 12:00:00 AM		Permit Finaled	07/08/2011 12:00:00 AM	ADDRESS	34.20274	-118.60137	CHANGE OF USE FROM LIBRARY  TO COMMUNITY CENTER/ CLASSROOM .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15683	10041-20000-25656	512 S RAMPART BLVD	90057	1	135A201   156	5155028018	R4-1	Central	Westlake		YES	2087.20	Electrical	Electrical	Apartment			12/28/2010 12:00:00 AM			Corrections Issued	02/16/2011 12:00:00 AM	ADDRESS	34.06325	-118.28054	New roof mounted 11.28 KW P.V. system (Casa Rampart 2).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15684	16041-20000-05825	114 E 60TH ST	90003	9	105B205   507	6006007011	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	33.98504	-118.27321	Plan check for PV roof mounted system. System size: 3.6kW with 17 modules and 17 microinverters Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15685	15041-10001-34683	129 S KINGS ROAD	90048	5	138B173   707	5511015022	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	05/26/2017 12:00:00 AM	ADDRESS	34.07355	-118.37236	Supplemental PC for changes to feeders 5,7 and 8. Changes clouded under delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15686	13041-10000-34950	11705 W VENTURA BLVD	91604	2	162B169   335	2368006025	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.14159	-118.388	T24 PART 6 ENERGY WORK FOR SINGLE STORY COMMERCIAL BUILDING. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX 1941 SQ FT. SCOPE OF WORK < 400A. E-PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15687	15041-10000-37661	9545 W WENTWORTH ST	91040	7	207B185   137	2549004026	A2-1, M1-1, P-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.26418	-118.34013	PV2, INSTALL 354 KW DC; 265 KW DC  ON THE GROUN AND 89 MOUNTED AS THE CARPORT SOLAR ARRAY.(1142) MODULES: HYUNDAI 310W (15) INVERTERS: SMA 20000TL-US PLUS ONE SMA 24000TL-USMAIN SERVICE PANEL 4000A, ADDING ONE (3 SECTIONS ) 1200A PANEL BOARD TAPPED FROM MAIN  AND 2 SUBPANEL(800A & 225 A)  AND ONE 6OA PANEL AS COMMUNICATION INTERFACE FOR CANOPY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15688	15041-20000-11446	748 S ALAMEDA ST Bldg B	90021	14	123A215   242	5166032027	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.03247	-118.23433	Plan check for T-24 only. Change of use from arehouse to food processing. Changes appaly to new restroom, men locker room, women locker room and break room.  Total area: 381 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15689	15041-10000-18837	437 S BROADWAY	90013	14	129A211    47	5149026008	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.04875	-118.25034	TI TO AN EXISTING COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD >400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15690	18041-10000-14971	227 N TIGERTAIL ROAD	90049	11	135B141   841	4403011026	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM			Reviewed by Supervisor	05/02/2018 12:00:00 AM	ADDRESS	34.06229	-118.47957	INSTALL A NEW ROOF MOUNTED 5,360 DC W, PV SYSTEM WITH 16 PANELS ON A SINGLE FAMILY HOME. ALSO INSTALLING AN LG 9.8KWh STORAGE BATTERY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15691	12041-10000-23954	1340 E 6TH ST 6TH FLOOR	90021	14	126A217   152	5164011001	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/09/2012 12:00:00 AM	ADDRESS	34.03813	-118.23423	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT ON THE SIXTH FLOOR OF EXISTING WAREHOUSE. UNIT #601-632	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15692	16041-20001-37490	1534 W FLORENCE AVE	90047	8	102B193  1368	6018005030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	11/17/2016 12:00:00 AM	ADDRESS	33.97441	-118.30372	expeditepv2install roof mounted pv sytem sized 10kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15693	16041-30000-35028	601 N AVALON BLVD	90744	15	030B205   803	7423001008	[Q]C2-2D-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	33.77736	-118.26257	Title 24 plan check.  Remove HID fixtures and replace with ne LED fixtures.  Total area = 16,865 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15694	16041-10000-32635	14950 W OXNARD ST	91411	4	177B145   472	2243022019	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.17917	-118.45903	Removing HID fixtures and replacing with new 15 LED fixtures PC T-24 only. Includes 960 sqft of indoor and 14915 sqft of outdoor area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15695	14041-10001-01577	10723 W LE CONTE AVE	90024	5	135B153   423	4360008017	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	04/15/2014 12:00:00 AM	ADDRESS	34.06407	-118.43872	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 5 kW DC roof-mounted solar array for a two story house, interconnect with exsisting service panel. (1) Transformerless inverter(s): Solaredge SE5000A-US. (20) Modules TRINA SOLAR TSM-250PA05.18.(20) Optimizer:SOLAREDGE OP250-LV-AH4SM-2NA-Z.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15696	17041-10002-12061	850 E 111TH PL	90059	8	088-5A209 241	6071022006	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	33.93557	-118.25914	POWER PLAN CHECK FOR A CHANGES TO AN APPROVED SET. CHANGES INCLUDES A NEW SERVICE UPGRADE TO 1200A, NEW 300 KVA XFMR, AND A NEW 1200A PANEL. ALL CHANGES ARE CLOUDED WITH DELTA 6,7,AND 8.ORGINAL SCOPE OF WORK: PC FOR POWER. INSTALLING A NEW COMPERESSED NATURAL GAS(CNG) VEHICLE FUELING SYSTEM. INCLUDES 3 COMPRESSORS, AND ONE FUTURE GAS DRYER. HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15697	12041-20000-21726	4516 S CENTRAL AVE	90011	9	112-5A209 170	5107008002	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.00239	-118.2563	REPAIR FIRE DAMAGED RETAIL SPACE.  LOAD IS LESS THAN 200 AMPS, PER APPLICANT.  CHANGE TO LIGHTING.  PLAN CHECK IS FOR ENERGY ONLY, WITH EMERGENCY LIGHTING.  Permit for New 200A service and 8 circuits is under 'Inspection'.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15698	10041-10000-16865	1309 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.05096	-118.22505	Solar voltaic system installed on the roof of the building.  Consists of  14 modules, 14 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15699	14041-10000-33503	1137 S BRONSON AVE	90019	10	129B189   363	5081003015	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.05155	-118.32355	Installation of new roof mounted solar PV array.  4 inverters with 110 modules (10 strings) and total system size = 25.8 kWac. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222. Zoning cleared on building permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15700	18041-20000-24383	1601 W PARK AVE	90026	13	139-5A209 306	5404018010	R3-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Apartment			06/29/2018 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	04/12/2021 12:00:00 AM	ADDRESS	34.07506	-118.25863	Plan check for power and energy for 11 units apartment building 3 story. 800A service. Total area: 9299 sq ft. B#16010-20000-06449	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15701	11041-10000-11173	5331 E HUNTINGTON DR NORTH Bldg #3	90032	14	145-5A237 252	5309017036	(T)[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Apartment			06/01/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	01/24/2012 12:00:00 AM	ADDRESS	34.09124	-118.16464	New fire alarm with 20 devices for Building 3 (out of 3 buildings).  Building 1 PCIS # is :  11041-10000-11167 Bilding 2 PCIS # is: 11041-10000-11171	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15702	11041-10000-27263	2636 W OLYMPIC BLVD	90006	1	129B197   272	5076009001	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.0522	-118.28987	"Doctor's office. Plan check for both power and energy. (CHANGE OF USE OF 43'-5"" X 129'-6""; ONE STORY OFFICE BUILDING TO MEDICAL OFFICE.  NEW NON-BEARING PARTITON WALLS; NEW ACCESSIBLE WOMEN'S RESTROOM.)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15703	17041-10001-04614	20179 W RINALDI ST BLDG A3	91326	12	213B113   266	2701004047	(T)C4-2D, A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.27523	-118.57313	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding site lighting, replacing exterior lights, revising panel schedules, and revising title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15704	18041-10002-41733	1901 S CREST DR	90034	5	126B169    95	4302007001	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	34.045	-118.38825	Expedite per applicant request.(((Plan check for a PV1 8.4KW AC/ 10.4KW DC roof-mounted solar PV system with (32) modules, (2) inverters, (2) subpanels, and (2) energy storage system interconnecting through the main service.Note. Portion of the permit fee is paid under 18041-90000-33282.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15705	17041-10000-03133	2049 S CENTURY PARK EAST 5TH FL-RESTROOMS	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY. T.I. IN BATHROOM  ON THE 5TH FLOOR. TOTAL AREA 410 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15706	13041-10000-32252	800 W OLYMPIC BLVD STE #102	90015		127-5A207 340	5138007***							Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.04484	-118.26453	TITLE 24 PART 6 ENERGY FOR (E) STARBUCKS. EMERGENCY FIXTURES ARE EXISTING AND IS NOT IN SCOPE OF WORK. NEW PENDANTS WILL BE CONNECTED TO EXISTING CKT. E-PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER. CREA ALREADY CLEARED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15707	17041-20000-42726	7920 N MARQUAND AVE	91304	12	189B089   209	2020029049	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.21397	-118.64831	pv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15708	15041-10001-33455	8821 S PERSHING DR # 2	90293	11	093B153   150	4117028029	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Approved	11/25/2015 12:00:00 AM	ADDRESS	33.9532	-118.44046	EXPEDITED RSES PLAN C HECK PER APPLICANT REQUEST.<<<PV1, INSTALL NEW 4.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON #2 UNIT APRTMENT OF AN APARTMENT BUILDING.(16) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15709	15041-20000-42940	515 S FIGUEROA ST #350	90071	14	130-5A209  98	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.05199	-118.25764	TENANT IMPROVEMENT WORK ON THE 3RD FLOOR. PC FOR ENERGY ONLY. TOTAL AREA: 860 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15710	17041-10000-15240	425 N BERNAL AVE	90063	14	127-5A229 182	5178025028	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.04143	-118.1936	Rooftop solar installation on SFD, system is 2.65 kW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15711	11041-10001-26802			13	148-5A187 177	5546007002	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Approved	01/12/2012 12:00:00 AM	PIN	34.10136973	-118.33068891	Revision to approved plans. Delta 1to Title 24 Energy Hookah lounge.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15712	12041-10000-13389	14080 W VENTURA BLVD	91423	4	165B153   485	2266013012	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM			PC Approved	06/08/2012 12:00:00 AM	ADDRESS	34.14924	-118.43984	Plan check for energy and emergency lighitng. Low rise commercial building. Occupancy below 99 people. 1080 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15713	13041-10000-24698	5522 N NAGLE AVE	91401	4	174B157   756	2344014059	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.17092	-118.42345	PV1 ROOF-MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECCT WITH MAIN PANEL IN A 2-STORY HOUSE. SYSTEM SIZE IS 6.75 KW DC. (27) TRINA 250W MODULES, POWER-ONE PVI 6000-OUTD-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15714	12041-10000-29634	196 S VERMONT AVE	90004	13	138B197  1248	5501012024	C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Expired	01/02/2015 12:00:00 AM	ADDRESS	34.07052	-118.29144	EXISTING H&R BLOCK OFFICE. CHANGE FROM T15 TO T8. NO EMERGENCY LIGHTING PER APPLICANT. METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15715	19041-10000-35071	6624 S STANFORD AVE	90001	9	102B205    57	6007017021	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	33.97903	-118.26285	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15716	12041-10000-22226	11670 N PALA MESA DR	91326	12	213B121    98	2822030016	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.28347	-118.55127	PV1 - INSTALLATION OF A ROOF-MOUNTED  4.16KW SOLARVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15717	11041-20000-25373	9157 N DE SOTO AVE A bld 2	91311	12	198B109   148	2746009047	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	01/05/2012 12:00:00 AM		Permit Finaled	03/07/2012 12:00:00 AM	ADDRESS	34.23726	-118.5888	quiznos tenant improvement new building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15718	12041-20000-01002	6920 N VAN NUYS BLVD	91405	6	183B149   499	2217009801	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.19604	-118.44846	New fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15719	15041-10002-07191	1547 N TOWER GROVE DR	90210	5	147B157   241	4356015022	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.09849	-118.42597	Plan check  FEEE IS CAPPED TO ZERO PER SENATE BIL # 1222.Change to approved set by reducing the number of module from (46) to (44) modules, equipment also being relocated. All changes are under delta-D only.(((PERMIT FEEE IS CAPPED TO ZERO PER SENATE BIL # 1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.6KW INTERCONNECTED WITH MSP.(46) MODULES: KYOCERA KU2606XPA(2) INVERTERS: PVI-3.0-OUTD-S-US-Z-A,(1) PVI-3.6-OUTD-S-US-Z-A)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15720	19041-20000-42759	12786 W VAN NUYS BLVD	91331	7	210B161   230	2536010016	[Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.27391	-118.41108	Power and lighting  (E) service to remain.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15721	18041-10000-47861	1040 N LAS PALMAS AVE BLDG 2	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/24/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP ON THE FIRST FLOOR AND NEW INITIATING DEVICES FOR EXISTING FIRE ALARM SYSTEM THROUGHOUT SCOPE OF WORK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15722	15041-20000-11267	6611 N WOODMAN AVE	91405	2	180B157   431	2238011007	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	PIN	34.190655	-118.43164511	Plan check for PV roof mounted 12kWac with 2 inverters(S,A A,EROCA SB70000 US) and 55 modules(HANWHA Q CELLS Q.PRO BFR-G3 260)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15723	14041-20001-08393	15836 W LONDELIUS ST	91343	12	195B141   683	2672012048	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.22915	-118.47764	Fee for expedite onlyPV1. Roof-mounted PV System with 5.75kw with optimizer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15724	14041-20002-17398	5268 N TUJUNGA AVE	91601	2	171B173   338	2350017008	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.16676	-118.37882	08/25/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to feeder sizing and distribution equipment.6/16/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO LOBBY AND CORRIDOR LIGHTING . APPROXIMATELY 6000SQFT. EMERGENCY LIGHTING EXISTING TO REMAIN*****Previous Work Description*****Plan check for power energy on new built hotel, 4 stories, with 43 guestrooms  and 1 dwelling unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15725	15041-10000-40350	539 N FULLER AVE	90036	5	141B181   980	5526023005	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.08136	-118.34994	PV1 SFD TOTAL SYSTEM SIZE 3KW. THIS SYSTEM IS ADDITION TO EXISTING SYSTEM. INSTALLING SUBPANEL TO TIE TO EXISTING.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15726	15041-10000-36508	421 W ELBERON AVE	90731	15	021B197   795	7448024004	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	33.75047	-118.28809	PV1 roof mounted solar system installation, interconnected with the main service panel. Scope: (1) Inverter: 3.0kw, (8) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15727	17041-20000-19995	1052 N HANLEY AVE	90049	11	138B137    28	4493018003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.07809	-118.49039	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15728	14041-10001-28536	6801 W HOLLYWOOD BLVD SUITE 127	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	"Change to approved set under the comment of inspection, lighting and control on the floor plan are not mached with plan check. All changes are under delta-6 only.Title 24 plan check only. Area = 461 sq. ft. Installating of two new panelboards and luminaires.Building permit: 14016-10000-20704.INVESTIGATION FEE Paid.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater. ""COMPLY WITH DEPARTMENT ORDER effective date08/20/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation. Ifadditional assistance is needed, please call Inspector GARY LYNCHat (213)252-3089 of ON-SITE SIGN ENFORCEMENT.  CEIS Case Numberis 579382.(Created: IMSV7 / 08-14-14)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~***END PRINT: 331285 (12/15/14 12:36)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15729	14041-10001-13430	903 S NEW HAMPSHIRE AVE 1-16	90006	10	132B197   836	5094025002	(T)(Q)R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.05572	-118.29316	REVISIONS TO PERMITTED SET OF PLANS; ADDED 2 EA NEW LIGHTING CKTS IN EACH APARTMENT ;REVISED TITLE 24((((PROPOSED 16 UNIT APARTMENT  W/ GARAGE.  4 STORY W/ MEZZ, TYPE IIIA CONSTRUCTION OVER TWO LEVELS (BASEMENT AND 1ST FLOOR)  OF TYPE I GARAGE.SPRINKLERS ARE BEING USE FOR AN INCREASE IN THE ALLOWABLE NUMBER OF LEVELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15730	16041-10000-34547	1460 S CENTRAL AVE	90021	14	121-5A213  91	5130011002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.02767	-118.2474	PC for energy only. Remove HID fixture and replace with new LED fixture. Total sqft = 5500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15731	14041-10000-06057	710 W HARRY BRIDGES BLVD	90744	15	027B205   665	7440007901	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			PC Info Complete	03/18/2014 12:00:00 AM	ADDRESS	33.7693	-118.27062	**Re-approved because the plan had expired. Permit under 16041-10000-01369METHANE MITIGATION PLAN CHECK FOR  PORT OF LOS ANGELES.  ELECTRICAL PC# 13041-10000-28992	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15732	16041-10000-20592	800 S FIGUEROA ST 6th Floor	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.04771	-118.26116	PC FOR ENERGY ONLY. Tenant Improvement to (E) office building building to remodel existing public corridors and restrooms to meet current Disabled Access requirements. TOTAL AREA 1427 SQ FT.B# 16016-10000-09750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15733	19041-10000-50084	4232 N VANALDEN AVE	91356	3	165B117   353	2177030015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	07/13/2020 12:00:00 AM	ADDRESS	34.14695	-118.5564	[EPLAN] $0 PER AB1414. PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 29  (POWERXT 360R-PD) MODULES, 29  (SOLAREDGE P400) OPTIMIZERS, 1 (SE7600H-US) INVERTER, 1 (SE 3000H-US) INVERTER,  1 TELSA POWERWALL, CONNECTED TO A NEW 200A PANEL. SYSTEM SIZE IS 10.44KW DC & 10.60KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15734	17041-10001-44237	205 1/2 N LAKE SHORE TER	90026	13	135A207   195	5159017009	R3-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.06457	-118.26115	Supplemental PC for change in word description:PC for 3.8 kW roofmounted solar PV.  Installing 11 modules with 3.8kW central inverter.Zero fees due to PV senate bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15735	18041-10000-48881	200 WORLD WAY TERM#2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	33.94558	-118.4039	TI FOR DELTA. SCOPE INCLUDES UTILIZIING EXISTING BRANCH CIRCUITS AND NEW LIGHTING FOR A LOUNGE/SEATING AREA. TOTAL AFFECTED AREA IS 2000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15736	15041-10000-35284	6801 PARK TERRACE Suite 130	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Issued	12/14/2015 12:00:00 AM	PIN	33.97719316	-118.39339881	Energy plan check for an office T.I ; Scope includes new lighting and receptacle. Total area 2862-sq feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15737	19041-20000-52892	4047 N TROPICO WAY	90065	1	150A219   184	5464031022	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.10521	-118.22334	PV1.  Install 5.94 kW DC / 5.47 kW AC CEC roof mounted PV system.  (18) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15738	13041-10000-33017	9050 W OSWEGO ST	91040	7	207B185   238	2547029002	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.26439	-118.32814	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 6.5KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(26) TRINA SOLAR # TSM-250(26) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE6000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15739	18041-10000-02457	10435 S SEPULVEDA BLVD	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	33.94046	-118.39718	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15740	17041-20001-03041	8800 S HOOVER ST	90044	8	096A201    80	6038013900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	33.95787	-118.28682	Revisions to approved plans.  Additional pole lights for pool lighting - Title 24 exempt.  (((New outdoor lighting for pool facilities and interior lighting for pool house pump rooms and lifeguard room.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15741	18041-20000-37831	10415 N MARY BELL AVE	91040	7	204B181   139	2543034032	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.25841	-118.34962	PV1.  Install 11.16 kW AC CEC roof mounted grid tied PV system.  (37) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15742	17041-10000-46012	330 S HOPE ST	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.05319	-118.25252	Plan check for power and energy for core and shell only of the the existing 3 story building food court pavilion and exterior plaza, and parking area. All switchgear and panels existing to remain and shall be reused for new circuits. Panels shown are for future vendor tenants; only new conduit shall be routed to vendor locations. Total area: 96355 sq ft. B#17016-10000-37992	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15743	16041-20000-39540	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM			PC Approved	11/08/2016 12:00:00 AM	ADDRESS	34.02201	-118.28947	New site lighting for hardscape around building currently under construction.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15744	18041-10000-30615	7851 W FOOTHILL BLVD	91040	7	204B193    98	2556029026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.02	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.25979	-118.30446	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15745	15041-10000-39998	6433 N FALLBROOK AVE	91307	12	180B097   434	2038040031	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.18751	-118.62365	PLAN CHECK FOR ENERGY ONLY FOR A BREAK ROOM TO AN EXISTING WALMART STORE. SCOPE INCLUDES NEW INDOOR AND OUTDOOR LIGHTING. TOTAL AFFECTED AREA IS 27850 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15746	18041-10002-09538	12020 W BURBANK BLVD	91607	2	174B165   752	2348002042	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM			PC Info Complete	09/28/2018 12:00:00 AM	ADDRESS	34.17198	-118.39447	"DELTA ""A"" changes to approved set of plans - changes include changing interconnection from line side tap to load side.  The total future new load is limited to 468Amp."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15747	17041-10000-45184	6836 S LA TIJERA BLVD	90045	11	102B173   161	4103002027	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	33.97646	-118.37247	PLAN CHECK FOR POWER AND ENERGY FOR COMMERCIAL CORE & SHELL ONLY - SCOPE INCLUDES NEW 800A DISTRIBUTION BOARD WITH PANEL BOARDS AND TRANSFORMERS. TOTAL AFFECTED AREA = 23,248 SQ. FT. FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15748	14041-20000-12381	16772 W MONTE HERMOSO DR	90272	11	135B117    69	4431031011	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.06887	-118.55351	Roof mounted PV system with system size 7.76 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15749	17041-20000-07884	8934 N GOTHIC AVE	91343	12	195B137   284	2688007016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.23301	-118.48934	Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with a 200A MSP.5kW ungrounded system. Each module has a 400W power optimizer. (22) 305W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15750	14041-20000-10257	9906 N AURA AVE	91324	12	201B117   109	2726021003	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.25032	-118.55431	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 9kW(2) SolarEdge #SE3800A-US-ZB-U transformerless inverter(36) Canadian Solar #CS6P-250PX pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15751	13041-20000-33984	17139 W VENTURA BLVD	91316	5	171B133   703	2258012025	(Q)P-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.16059	-118.50671	PC FOR T24 ENERGY ONLY. RETAIL W/ STORAGE. TOTAL AREA 730 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15752	12041-10007-29913	12760 W MILLENNIUM BLDG A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM			PC Approved	06/15/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	"DELTA 63 CHANGES TO PERMITTED SET OF PLANS: ON ALL LEVELS, CHANGES TO LIGHTING SYSTEM INCLUDING THE REMOVAL OF PLANTERS"" LUMINAIRES ON THE ROOF. aLL CHANGES ARE CLOUDED AND IDENTIFIED WITH ""DELTA 63 "" MARKINGS.(((((((PLAN CHECK POWER AND ENERGY FOR NEW 4-STORY 100 UNIT APARTMENT COMPLEX. BUILDING 'A'."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15753	18041-10000-40027	8614 N WOODLEY AVE	91343	12	195B141   789	2673001054	P-1VL, [Q]C1.5-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Issued	10/19/2018 12:00:00 AM	ADDRESS	34.22698	-118.48495	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY, Total sq. ft. 3600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15754	15041-20000-39765	3515 S RAYMOND AVE	90007	8	120B197   795	5040004003	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Expired	12/27/2017 12:00:00 AM	ADDRESS	34.02411	-118.29818	PV1. NEW SOLAR SYSTEM ON EXISTIN RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.5KWac.(10)MODULES-BOVIET 260W.(1)INVERTER-FRONIUS GALVO 2.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15755	14041-20000-12388	7209 S SEPULVEDA BLVD	90045	11	102B165   449	4110003002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	33.97496	-118.39451	PV1.  Install 6.8 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15756	13041-20000-26752	7441 W KYLE ST	91042	7	207B197   397	2566013071	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.26545	-118.29469	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.3 SKW AC USING 20 MICROINVERTER ENPHASE M215. NONSTANDARD PLAN. PC REQUIRED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15757	18041-20000-14617	115 W 59TH PL	90003	9	105B201   283	6005012018	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	33.98616	-118.27454	Plan check for solar PV roof mounted system with battery back up system. System size: 7.6kWac with 33 modules and 1 inverter(7.6kW) , 1 DC battery 9.8kWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15758	16041-20000-08656	13930 W JUDD ST	91331	7	204B153   109	2618018019	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM			Reviewed by Supervisor	03/30/2016 12:00:00 AM	ADDRESS	34.25936	-118.43654	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3kW. Ungrounded system. One 300W power optimizer per module.(7) 285W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15759	14041-10000-34947	8750 N VANALDEN AVE	91324	12	195B121   341	2784003027	M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.22954	-118.54906	Plan check for Title 24 only. Project scope is to remove existing HID fixtures and replace them with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15760	14041-20000-11194	16830 W VENTURA BLVD Ste 400	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.15886	-118.50032	T.I. to existing building on 4th floor.  Install and relocate general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15761	15041-10000-04956	19923 W VENTURA BLVD	91367	3	174B113   372	2164001015	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM			Reviewed by Supervisor	03/05/2015 12:00:00 AM	PIN	34.17250087	-118.56671907	Plan check for power and energy(core and shell) 3-story Medical office Building( including pharmacy on  ground floor) 800A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15762	17041-20000-19052	1680 N VINE ST Suite 1212	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for Title 24 only. Project site is an existing tenant space in a commercial building. Project scope is a tenant improvement. Total lighting area = 2,532 sq. ft.Note: Building application has been generated under 17016-20000-09456	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15763	16041-20000-21226	10346 W DIAMOND ST LOT 14	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15764	16041-10000-13917	13160 W MINDANAO WAY 3RD FLR	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	33.98501	-118.43726	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTIG MEDICAL OFFICE BUILDING ON THE 3RD FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE/EXAMINATION ROOMS. TOTAL AFFECTED AREA IS 16355 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15765	13041-10000-22409	21315 W ROSCOE BLVD 1-150	91304	3	192B105   549	2779013009	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Apartment			08/19/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.21999	-118.59568	Remodel of existing recreational room, title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter. asbuilt plan check under 13041-10000-24146 mt 9/4/2013	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15766	18041-20000-00644	2343 N ALTMAN ST	90031	13	144B213   384	5445029013	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.09185	-118.23851	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15767	13041-10000-31499	1236 W LEIGHTON AVE ste#1	90037	8	117B197  1164	5037003003	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.01307	-118.29858	PV1, Install 2 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US. 8 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15768	16041-10001-44595	21315 W LOPEZ ST	91364	3	171B105   946	2167006017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.16233	-118.59531	PC FOR CHANGE TO LAYOUT ON ROOF. NO OTHER CHANGES NOTED. RESTAMPING PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15769	14041-20000-12137	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	ADDRESS	34.06237	-118.35809	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ONLY ON AN EXISTING COMMERCIAL HIGH RISE BUILDING  FOR THE 30TH FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15770	12041-10000-29820	444 S FLOWER ST SUITE 3900	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	12/14/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. SCOPE OF WORK IS 703 SQUARE FEET PARTIAL FLOOR IN A HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15771	13041-20000-33834	5232 N GOODLAND AVE	91607	2	171B161   408	2346024017	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.16589	-118.41195	pv1 single family dwelling. total aystem size 7.6kw ac using 33 modules. transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15772	11041-10000-27612	645 W 9TH ST #111	90731	15	015B197   873	7454010006	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM			PC Info Complete	10/11/2012 12:00:00 AM	ADDRESS	33.73594	-118.29109	Install general/emergency lighting on first floor of existing building.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15773	16041-10001-08258	9532 S GRAPE ST	90002	15	093A215   158	6046014045	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	33.9496	-118.23616	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(14)MODULES-KYOCERA #KD255GX-LFB3(1)INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-ANOTE: PERMIT PULLED UNDER PCIS#16041-90000-08258(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15774	14041-10000-17461	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Title 24 plan check only.  Total area = 1,016Elevator lobby buildout in existing highrise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15775	16041-20001-43900	4719 N CALHOUN AVE	91423	4	168B153   478	2248028013	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.15663	-118.44231	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.(N) 3kW ungrounded system. (8) 265W pv modules. There is an existing 3.8kW ungrounded system installed on the SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15776	14041-20000-09683	23640 W VICTORY BLVD	91367	3	180B093   854	2035008020	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.18641	-118.64188	pc for ti. new lighting. restaurant.. pc for t24 energy only permit already issued	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15777	15041-10000-07254	2950 S VAN BUREN PL	90007	8	120B197   279	5054014022	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	34.02777	-118.29685	PV2, INSTALL 13.5 KW AC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE TO MAIN SERVICE PANEL.(55) MODULES ,(3) INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15778	14041-10000-31404	581 W 92ND ST 1-10	90044	8	094-5A201 153	6039016015	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			11/12/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.95292	-118.28474	PV1 SYSTEM SIZE: 25.7kW. 3 inverters (Delta Solivia 7.6TL,(7.6kw)) with 90 modules ( Model: LDK-280P-24 ), and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15779	17041-20000-23948	15260 W VENTURA BLVD ste 1080	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM			PC Info Complete	07/17/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	ti to an existing commercial high rise building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15780	18041-10001-15377	17950 W PARTHENIA ST	91325	12	195B129   429	2787001019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.22845	-118.52472	INSTALL A NEW 17KW PV SYSTEM WITH 54 MODULES AND BACKUP BATTERIES ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15781	17041-10000-01735	725 S FIGUEROA ST #1080	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Issued	02/28/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only in existing high-rise building. Total area: 2834 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15782	14041-10001-09802	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	on original submittal, these existing elevators remained existing; now, these existing elevator motors are refurbished with smaller motors thus leaving existing elevator circuits/ feeders in plave; disconects are replaced per NEC and new wiring from disconnect to motors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15783	17041-20000-25822	22540 W VALERIO ST	91307	12	186B097   732	2022022004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.20453	-118.61831	pv1install roof mounted pv system sized 5.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15784	17041-20001-10020	6882 S ARIZONA AVE	90045	11	102B165   127	4110001028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	33.97776	-118.39577	SOLAR EXPEDITE FEE.3 kw roof top single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15785	14041-10000-13909	13604 W SHERMAN WAY	91405	2	183B157    75	2328008008	(T)(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			05/23/2014 12:00:00 AM			Verifications in Progress	04/14/2015 12:00:00 AM	ADDRESS	34.20102	-118.4293	PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY ON A 64 UNIT AFFORDABLE APARTMENT WITH 100 MODULES. 10 STRINGS. THE DRAWING FOR SOLAR PLAN COMES WITH ORIGINAL PLAN  WITH APPLICATION #14041-10000-13895.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15786	15041-10000-16436	6134 W 75TH PL	90045	11	102B165   867	4106007018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	33.97212	-118.3932	PV1.  Install 6.87 kW DC roof-mounted, utility-interactive PV system.  Simplified central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15787	16041-10000-13509	13321 W BURBANK BLVD #10	91401	2	174B157   496	2343017019	[Q]C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.17231	-118.42313	TI to an (E) commercial build. on Ste. #10. Install new lights and controlled receptacles. PC for Energy only, total area: 1,821 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15788	17041-20001-21182	14353 W POLK ST	91342	7	225B149   363	2504015007	RD6-1XL-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM			PC Approved	07/05/2017 12:00:00 AM	ADDRESS	34.31126	-118.44602	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.10kW ungrounded system. (33) 330W pv modules.Each module has a 370W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15789	19041-10000-52046	10949 N MCVINE AVE	91040	7	210B193   785	2551026031	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.2684	-118.31162	NEW ROOF MOUNTED 5.185 KW (DC) PV SYSTEM WITH 17 PV MODULES (305W), 17 OPTIMIZERS,  AND 1 @ 3.78KW INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15790	16041-20000-19211	6600 N TOPANGA CANYON BLVD #1570	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Closed	08/15/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for 1st time tenant in Village at Westfield Topanga Hanna Andersson. Total area: 1,572 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15791	17041-10001-41690	5028 N CARTWRIGHT AVE	91601	2	171B177  1128	2419014007	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.16207	-118.36357	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15792	14041-20000-04993	7265 N SHOUP AVE	91307	12	186B101   888	2022023011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.20279	-118.61488	pv1 single family dwelling. total system size 4.2 kw ac using 19 modules. transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15793	15041-10000-38972	701 E 3RD ST 3rd fl	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	PIN	34.04581508	-118.23784015	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 13030	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15794	17041-20001-36398	7751 W VERAGUA DR	90293	11	099B153    56	4114002018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM			Reviewed by Supervisor	10/16/2017 12:00:00 AM	ADDRESS	33.96509	-118.43308	Expedited plan check fee.  PV1.  Install 16.64 kW DC roof mounted grid tied PV system. Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15795	12041-20000-30327	14915 W BURBANK BLVD	91411	4	174B149   811	2243010027	C1.5-1VL, R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Info Complete	02/12/2013 12:00:00 AM	ADDRESS	34.1723	-118.45814	Plan check for power. 1600A service upgrade and two transformers. All loads are existing and/or seperate permit. 14929 1/2 (200A service upgrade is on a seperate permit)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15796	12041-20000-25992	11239 W VENTURA BLVD	91604	2	162B173   294	2366035036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.14181	-118.37523	"T. I. / REMODEL TO (E) RETAIL.  Load is less than 400 amps per applicant.  Plan check only for Energy, with Emergency lighting.  Panel ""MDP"" is existing and load is 384.6 amps per plan."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15797	16041-20000-01520	9260 N TOPANGA CANYON BLVD	91311	12	198B101   288	2746013034	[Q]MR1-1, [T][Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	12/21/2022 12:00:00 AM	ADDRESS	34.23886	-118.60584	TI to existing commercial building (datacenter). Plan check for power and energy. Adding new lighting. Total sqft. 3,291.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15798	13041-10000-27268	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	INSTALLATION OF A NEW FIRE ALARM SYSTEM AND TO PROVIDE 24-HR SYSTEM MONITORING TO SPRINKLER SYSTEM IN SINGLE STORY BUILDING ( PLUS MEZZANINE). 101 DEVICES, 1 FIRE ALARM PANEL, 1 ANNUNICATING PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15799	10041-10000-03491	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	02/26/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	Tenant improvement in existing office spacesplan chk is for title 24 and 11 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15800	11041-10000-17783	1625 W 190TH ST	90248	15	060B193   387	7351001024	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	33.85851	-118.30846	new offices/restrooms /storage inside a  warehouse buildingplan chk is for title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15801	17041-10000-14951	2780 W SAN MARINO ST	90006	1	132B197   992	5076003900	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.05489	-118.28847	PC for energy only, Removing HID fixtures and replacing them with new LED. Area: 8,300 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15802	10041-20001-14353	1680 N VINE ST	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM			PC Approved	10/29/2010 12:00:00 AM	ADDRESS	34.10133	-118.32648	Delta 2 revision plan check. Change consist of removing submeter on the 4000A section and change AIC bracing from 100KAIC rating to 65KAIC on the MS section.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15803	08041-10001-24317	5700 S HOOVER ST	90037	9	108B201  1167	5001018030	[Q]C2-1	South Los Angeles	South Los Angeles			2327.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	33.9904	-118.28692	CHANGE OF USE FROM A HOSPITAL TO OFFICES. PLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS. UPGRADE SERVICE TO 400A NEW HEAT PUMPS ;CIRCUITS ARE EXISTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15804	14041-10000-21257	1806 S SHENANDOAH ST	90035	10	126B169    61	4303015002	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.04533	-118.38308	Installation of 4.845kW roof-mounted PV system on transformerless inverter with power optimizers. 1 Inverter 3800 Watts.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15805	18041-20000-48646	723 W COEUR D'ALENE AVE pv1	90291	11	108B149  1347	4237020004	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2018 12:00:00 AM	12/24/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	PIN	33.98962225	-118.45406923	pv1install roof mounted pv system sized 5KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15806	15041-20000-30788	6242 N WILBUR AVE	91335	3	177B121   231	2127013067	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Issued	10/21/2015 12:00:00 AM	ADDRESS	34.18405	-118.54455	PV1, ROOF MOUNTED SYSTEM. (49) MODULES AND 1 CENTRAL INVERTER. TOTAL SIZE 10KW. (49) KYOCERA #KU2656ZPA(1)SOLAREDGE #SE10000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15807	13041-10000-02775	7543 N LOMA VERDE AVE	91303	3	186B109   322	2112001120	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM	02/04/2013 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.20769	-118.58979	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. SYSTEM SIZE OF 9.36 KW. USING 39 MODULES OF TRINA SOLAR TSM-240PA05. CENTRAL INVERTER SMA SUNNY BOY 8000-US. SINGLE STORY PV1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15808	16041-10001-32830	1722 E 16TH ST	90021	14	120A213   207	5167002033	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.02315	-118.24168	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES INCLUDE REORGANIZATION OF LOADS ON PANEL SCHEDULES. ADDITION OF 1 NEW PANEL TO SUPPLY ADDITIONAL LOADS. REVISED LIGHTING PLAN, FIXTURES AND PROVIDED UPDATED T24 DOCUMENTS. PERMIT FOR ADDITIONAL WORK WILL BE PULLED UNDER THIS APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15809	13041-10002-26325	1205 W 3RD ST	90026	1	132A209    95	5152013019	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	PIN	34.05699675	-118.25804943	CHANGES TO APPROVED SET OF PLANS. CHANGES ARE CLOUDED. FEERDER AND CONDUIT SIZE GOING TO PANEL AND PANEL B CHANGED ONLY. SIZE OF THE FUSE FOR THE BREAKER CHANGED FROM 200 TO 100.13041-20001-26325 .New restaurant.  PLAN CHECK FOR POWER ONLY REQUESTED BY THE APPLICANT.   Load is less than 400 amps. T-24 AND EMERGENCY LIGHTING PLAN CHECK ARE ON THE MAIN APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15810	17041-20002-42949	840 N OGDEN DR	90046	5	141B177    49	5527004004	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.08657	-118.35935	"Revision to approved set of plans.  Removal of ESS from system scope.  Permit issued for change of work description.  Work description updated to:""PV1.  Install 7.5 kW roof mounted grid tied PV system.  (25) modules with string inverter.""$0 permit fee per State Senate Bill SB 1222."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15811	16041-10000-23835	7712 N KLUMP AVE	91352	6	189B173   896	2315004015	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.21064	-118.37564	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6.02 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15812	13041-10000-28705	255 S HILL ST	90012	14	130-5A211  15	5149010264	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM	02/24/2015 12:00:00 AM		Issued	02/24/2015 12:00:00 AM	ADDRESS	34.05197	-118.24904	Renovation of Agape Center apartment complex common areas (5 stories).  Replace lighting in corridors and common areas.  Add receptacles for the new remodel changes.  Newly connected load in excess of 400A.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15813	18041-20000-12882	4710 N SANTA LUCIA DR	91364	3	168B105   898	2171021057	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.15297	-118.60418	PV1.  Install 6.0 kW DC roof mounted grid tied PV system.  (20) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15814	17041-20000-07859	2282 N MANDEVILLE CANYON ROAD	90049	11	138B133   487	4493004011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.0772	-118.50001	Plan check for power only. New 2-story SFD over basement and detached pool house. 800A service. 10,083sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15815	16041-10001-11034	4418 VINELAND AVE	91602	4	165B173   268	2423008001	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM			PC Approved	04/01/2016 12:00:00 AM	PIN	34.15104824	-118.36988917	[PC Only]   Revision to approved plan under Delta-1. ***TI to an (E) office build. Scope include (partial) 1st and 2nd fl. corridor and restrooms. Install new light fixtures. PC for T-24 only. Total area: 2,397 sq. ft.***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15816	19041-20000-35656	3330 N EDLOFT AVE	90032	14	142-5A231 296	5213034016	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.08342	-118.18403	Plan check for PV roof mouned system, PV system size: 3.48KW with 12 PV Modules and 1 inverter(3.8KW) and LG Chem RESU  9.8KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15817	17041-20000-06968	13243 N CONSTABLE AVE	91344	12	225B133   181	2601014021	RS-1, RS-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.31096	-118.50528	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW.  CENTRAL STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15818	17041-30001-31009	444 S FLOWER ST STE 1550	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.05189	-118.25546	03-29-2018 Changes to an approved set of plan. Changes include re-configure 3 office to 1 room. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15819	16041-20000-37736	252 S RAMPART BLVD	90057	13	136-5A203 304	5155025900	R4-1	Central	Westlake	Greater Echo Park Elysian	Yes	2086.20	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	11/02/2020 12:00:00 AM	ADDRESS	34.067	-118.27813	PC FOR 23 units apartment building. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15820	10041-20000-12655	630 W 6TH ST #110 A	90017	9	129A209   260	5144005***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.04916	-118.25624	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15821	13041-20001-05316	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM			PC Approved	11/08/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	change medium voltage tap conductors to 4/0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15822	17041-10000-08471	19191 S VERMONT AVE 9th FL-common	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	33.85656	-118.29099	Plan check for Title 24 T.I. in common area and restroom 9th floor in high-rise building. Total area: 1643 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15823	19041-10000-39356	6160 N LAUREL CANYON BLVD 175	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	FULL PC FOR A FIRST TIME TENANT (COFFEE SHOP), SCOPE OF WORK INCLUDES TWO NEW SUBPANELS, A NEW TRANSFORMER, CONNECTED TO AN EXISTING 600A SWITCHBOARD. TOTAL AFFECTED AREA IS 1242 SQFT. B#: 19016-10000-17732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15824	16041-10000-44673	3708 N BARHAM BLVD (BUILDING-D)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.14083	-118.34142	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15825	19041-10000-21095	420 E BOYD ST	90013	14	129A213   362	5147006001	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.04601	-118.24206	pc for new FA system for commercial building (offices and retail) , 1 FACP and 144devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15826	16041-20000-28137	6300 W WILSHIRE BLVD	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check Title 24 only  in existing lobby Renovation T.I. Total area: 8,044 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15827	19041-10000-06157	2634 N SILVER RIDGE AVE	90039	13	150A209   263	5438013001	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.1037	-118.25739	PC FOR GROUND MOUNTED PV FOR SFDTOTAL SYSTEM SIZE 18.09KWDC/ 14.4KWACSCOPE INCLUDES TWO 7.7KW INVERTERS AND 54 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15828	18041-20000-23609	4933 N TEXHOMA AVE	91316	5	168B129   102	2290009011	RE9-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.16013	-118.51666	Plan check for a PV1 roof-mounted PV system. System size is 10.71 kWdc/9.72 kWac-CEC and consist of (1) 11.4 kWac rated inverter and (34) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15829	17041-10000-04715	2926 W 73RD ST	90043	8	102B189  1620	4009005006	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.97353	-118.32534	ROOF MOUNTEDPV SYSTEM USING CENTRAL INVERTER 10KW AC AND TOTAL OF 42 MODULES WITH POWER OPTIMIZERS.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15830	16041-10000-37790	950 S BARRACUDA ST PV	90731	15	015B205    30	7440032905	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	PIN	33.73353997	-118.26217778	Zero fee permit per California Senate Bill 1222.PC FOR PV SYSTEM. TOTAL SYSTEM SIZE OF 1270KW WITH 3705 MODULES IN TOTAL AND 13 INVERTERS. ROOF MOUNTED. THIS IS FEED IN TARRIF PROJECT (FIT)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15831	15041-10000-41412	833 N GAFFEY PL	90731	15	021B197   748	7448005013	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	33.75066	-118.29243	PV1, INSTALL 2.65 KW DC ROOF-MOUNTED SOLAR ARAY ON A SINGLE FAMILY HOUSE.(10) MODULES: KYOCERA KU2656ZPA(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15832	19041-20000-51391	1829 N COLDWATER CANYON DR	90210	4	150B165   301	4352001008	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	ADDRESS	34.10401	-118.40559	PV1. INSTALL 16.060 KW DC PV SYSTEM WITH (44) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15833	16041-20000-23000	21800 W OXNARD ST #500	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for Title 24 in existing space office. Total area: 18,479 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15834	18041-20002-04909	501 N SOTO ST	90033	14	129A225   101	5175009029	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			08/22/2018 12:00:00 AM			PC Approved	10/25/2018 12:00:00 AM	ADDRESS	34.04865	-118.20687	Revisions to approved set.  Change of inverter type from central inverter to microinverters, change of module type, and splitting of the system into multiple interconnection points via feeder taps. Total system size has remained the same.*****Previous Work Description*****(((Plan check for a PV2 roof-mounted Pv system. System size is  11.4 kWac/15.0 kWdc and consists of (1) inverter and (50) modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15835	18041-20000-03386	110 W 119TH ST	90061	15	084B201  1033	6087022010	C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2414.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	33.92455	-118.2744	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15836	17041-20001-33831	3127 S CORINTH AVE	90066	11	120B157   631	4250022020	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.02416	-118.43129	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.11.4kW ungrounded system. (40) 330W pv modules.Each module has a 400W power optimizer.Derating main breaker to 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15837	14041-10000-31814	12950 W ADMIRAL AVE	90066	11	105B157   470	4223006017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	33.98456	-118.4302	PV1 Rooftop residential PV System size: 4.25kW with 1 inverter(Power-one: PVI-4.2-OUTD-S-US-A) and 17 Modules (LG PV Dodule: LG250S1C-G3)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15838	13041-20000-18104	752 S MAIN ST	90014	14	127-5A211 211	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.04283	-118.2527	upgrade service to two 600 amps 1200 amps pull section	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15839	13041-20000-28197	601 S FIGUEROA ST 19th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	T24 FOR EXISTING BATHROOM IN HIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE 19TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15840	12041-10001-09132	1034 S CATALINA ST	90006	10	129B197   357	5078012017	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Expired	11/24/2014 12:00:00 AM	ADDRESS	34.05171	-118.29462	Changes to approved plans.Change the Engineer,  Change to point of connection of PV system and upgrade to 600A service. (This plan was submitted with contractor design and all the plan check fee will be paied with the permit fee for this new design )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15841	13041-10000-22910	17134 W DEVONSHIRE ST 2nd floor	91325	12	204B133   208	2694001054	QCR-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	34.25736	-118.50622	T24 for existing office remodel in existing 2-story office building.  T24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15842	16041-20000-06143	9801 N SHOUP AVE	91311	12	201B101   242	2727004013	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2016 12:00:00 AM			Reviewed by Supervisor	03/03/2016 12:00:00 AM	ADDRESS	34.24818	-118.61505	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derating main to 150A.System size: 14kW (7+7). Ungrounded system. (52) 300W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15843	10041-20000-06564	12701 W VAN NUYS BLVD UNIT N	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.02	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	04/12/2010 12:00:00 AM		Permit Finaled	05/17/2010 12:00:00 AM	ADDRESS	34.27621	-118.41056	Installing lighting and some receptacles in office areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15844	16041-10000-14798	12777 W JEFFERSON BLVD 2ND FLOOR	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	33.9778	-118.41768	CHECKING TITLE 24 AND POWER FOR FIRST TIME TENANT. TI OF 2ND FLOOR. SCOPE OF WORK INCLUDES T24 NEW ELECTRICAL EQUIPMENT, LIGHTNG & LIGHTING CONTROLS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15845	10041-30000-10990	15400 W SHERMAN WAY	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	06/10/2010 12:00:00 AM		Permit Finaled	07/30/2010 12:00:00 AM	ADDRESS	34.20099	-118.46839	Lighting and receptacles configuration for existing office area.  This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15846	17041-10002-38270	723 N JUNE ST	90038	4	141B185   453	5524008009	R1R3-RG	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.08413	-118.3343	PC FOR CHANGES TO APPROVED SET PER APPLICANT REQUEST. SCOPE INCLUDES REMOVAL OF SUBPANEL AND RESIZING BREAKERS. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15847	17041-20000-02856	10901 N SWEETWATER CT	91311	12	210B117   337	2708027***	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Issued	01/27/2017 12:00:00 AM	ADDRESS	34.26858	-118.56499	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15848	15041-20000-20666	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	34.09676	-118.29487	Fees were adjusted due to pre-made check. Plan checker should verify fees. Green Building fee was taken out.TI to existing high rise commerical building. Plan check for power and energy. Adding new lighting including emergency. Adding new 1200A service. Total sqft. 55,001.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15849	14041-10000-09662	1040 S LOS ANGELES ST 10-18	90015	14	126A209   222	5145020004	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.03858	-118.25669	"plan check for power and energy. methane zone. new 2 story. no common roof per applicant. 2of2 (service fees under bldg A). BLDG#12010.10.01397: PROPOSED NEW  WHOLESALE/RETAIL BUILDING ""B"" 20' X 129' (TOTAL 9 SPACES) TYPE VA CONSTRUCTION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15850	19041-20000-34762	12700 W VENTURA BLVD Gnd Floor-3rd Floor	91604	2	162B161    29	2384022049	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.14449	-118.40998	T24 PLAN CHECK FOR TI TO GND FLOOR, 1ST FLOOR, 3RD FLOOR, AND MEZZANINE. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 6,545 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15851	14041-10003-05451	700 N FAIRFAX AVE	90046	5	141B177   515	5527011005	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	34.0841	-118.36119	((11/10/2014 - Sup. application for changes to approved set at request of inspector.  Title 24 plan check only.  Total area = 867 sq. ft.  Changes to luminaire type and removal of some luminaires to meet power allowance.))FULL PLAN POEWER AND ENERGY(RETAIL TO REATURANT) TOTAL AREA 887 SQ FT.PANEL R2 TO BE DELETED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15852	10041-10000-17720	6355 N DE SOTO AVE Bldg 1	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.18639	-118.58869	New 2-story Clubhouse for 4-story ___ -unit apartment  bldg( separate application )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15853	10041-20000-14198	2121 S AVENUE OF THE STARS 27th Floor	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM	07/22/2010 12:00:00 AM		Permit Finaled	08/24/2010 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check T-24 Energy (general/emergency) lighting TI on the 27th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15854	18041-10000-15182	9010 S BELLANCA AVE	90045	11	093B169    18	4125010012	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.9548	-118.38038	REMOVE EXISTING HID FIXTURES AND REPLACE THEM WITH NEW LED FIXTURES. TITLE 24-ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15855	18041-20000-36087	11530 W DONA TERESA DR	91604	2	159B169   542	2381012005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.13066	-118.38456	pv1install roof mounted pv system sized 11.3KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15856	13041-10000-35277	6255 W SUNSET BLVD STE #1520	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	T24 PART 6 ENERGY FOR (E) OFFICE SPACE .  SCOPE OF WORK < 400A. PROJECTED AREA IN SCOPE OF LIGHTING WORK IS APPROX. 688 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15857	16041-20001-44118	7843 N MELITA AVE	91605	12	189B157   678	2303011043	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.21291	-118.42022	EXPEDITED PER APPLICANTS REQUEST.PV1.  Install 7.6 kW roof mounted grid tied PV system with battery backup.  (25) modules with (1) 7.6 kW rated central inverter with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15858	14041-10008-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			05/24/2019 12:00:00 AM			Re-Submittal Required	06/04/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	Change to an approved set by modifying the lighting and equipment to match with as build. Note. changes applied through out the floor plan mainly with lighting, emergency photometric and load being updated. proof of change of engineer also provided.All changes under delta 17 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15859	19041-10000-51329	8373 W MELROSE AVE	90069	5	141B173   438	5528002009	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	03/17/2020 12:00:00 AM		Permit Finaled	02/02/2021 12:00:00 AM	ADDRESS	34.08378	-118.37254	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND POWER. TOTAL AFFECTED AREA IS 1955 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15860	17041-20001-30187	8334 N WILBUR AVE	91324	12	192B121   680	2785019015	RA-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.22158	-118.54464	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.9.52kW ungrounded system.(34) EnPhase IQ6PLUS-72-2-US microinverters.(34) 350W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15861	16041-10000-12010	1801 CENTURY PARK EAST STE.. 850-860	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	PIN	34.0621869	-118.41581732	TI on (E) office build. 8th floor. Suite #850 & #860. Install new lights and controlled receptacles to the existing ckts. PC on T-24 only, total area: 3,373 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15862	10041-20000-17255	604 W C ST	90744	15	027B205   232	7417019921	M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Closed	11/03/2011 12:00:00 AM	ADDRESS	33.77218	-118.26861	pv system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15863	19041-20000-18928	23057 W ERWIN ST	91367	3	177B097   215	2039010006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Issued	05/20/2019 12:00:00 AM	ADDRESS	34.18293	-118.62974	PV1.  Install 17.99 kW PV system.  (55) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15864	19041-20000-40675	12820 S FIGUEROA ST	90061	15	081B201   287	6132015064	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	06/09/2020 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	33.91593	-118.28252	New distribution, power, and lighting for (E) commercial building.  Plan check for power and energy.  Associated building permit under 19016-10000-33357.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15865	14041-10000-08086	14442 W OSBORNE ST	91402	6	195B149   159	2639014015	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.23304	-118.44735	PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(12)modules: {Trina {TSM-250PA05.08}}]SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15866	17041-20001-22494	941 S FEDORA ST	90006	10	132B197  1034	5094022036	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.05469	-118.29779	08-23-2019 Changes to an approved set of plan, Changes include residental feeder conductors from copper to aluminum. All Changes has been clouded as delta 1. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15867	18041-10000-16597	1999 S AVENUE OF THE STARS #900	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLAN CHECK FOR TITLE 24 ONLY FOR NEW 1-HR RATED CORRIDOR AND TENANT IMPROVEMENT TO CREATE 2 SUITES ON THE 9TH FLOOR. TOTAL AFFECTED AREA = 1455 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15868	17041-20000-22381	8962 N CORBIN AVE	91324	12	195B117    34	2783025080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	PIN	34.23337501	-118.561666	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE FROM (E) RETAIL SPACE (1190 SQFT) TO (N) DENTAL OFFICE.building p# 17016-20000-16456	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15869	15041-10000-05966	3320 E PEPPER AVE	90065	1	145-5A219 456	5453016900	PF-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Public Safety Only			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.09094	-118.22283	NEW FIRE WARNING SYSTEM FOR SINGLE STORY COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15870	19041-30000-44085	10800 W PICO BLVD Suite M2	90064	5	126B157   893	4255028014	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.04054	-118.4272	PLAN CHECK FOR ENERGY ONLY, T-24. SCOPE OF WORK INLCUDES NEW  LIGHTING ONLY. TOTAL SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15871	13041-20000-20214	6244 N BELMAR AVE	91335	3	177B117   224	2131022011	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.18419	-118.55807	New rooftop PV system for an existing single family residence.  System is Ungrounded and uses Power Optimizers.  Service and panel upgrade are included in Permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15872	18041-20000-06708												Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM				VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15873	18041-30000-19501	11906 W SAN VICENTE BLVD BASEMENT	90049	11	129B145  1149	4265007036	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Approved	05/24/2018 12:00:00 AM	ADDRESS	34.05239	-118.47055	Energy plan check for a change of use T.I . Scope include new lighting and and equipment; Total area is 1256-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15874	15041-20000-23096	17517 W WEDDINGTON ST	91316	5	171B129   103	2257004060	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.1669	-118.51503	PC FORPV SYSTEM. 26.1KW AC USING 4 INVERTERS TOTAL. SYSTEM IS UNGROUNDED. TOTAL OF 74 MODULES IN TOTAL.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15875	14041-20000-00744	5333 N VENTURA CANYON AVE	91401	4	171B157   217	2344028017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.16754	-118.42925	New rooftop PV system with DC/DC converters.  System is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15876	15041-10000-21658	855 W 126TH ST	90044	15	081B197   237	6117017018	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	33.91796	-118.29075	PV1, ROOF MOUNTED SYSTEM. (28) MODULES (1) INVERTER. TOTAL SIZE 7.28 KW(28) KYOCERA #KU2606XPA (1 ) PV1-6000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15877	13041-10000-08248	1500 S SEPULVEDA BLVD	90025	5	129B149    50	4324020037	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			04/01/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.05034	-118.44633	Fire alarm panel replacement and adding few devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15878	17041-10000-35318	7610 W DAY ST	91042	7	204A197   231	2558035037	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.25444	-118.29835	CHANGE OF USE FROM RETAIL TO OFFICE- SUITES 100 &101PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15879	18041-20000-35277	2406 N EADS ST	90031	13	144B213    70	5445002021	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.09452	-118.24019	first time tenant.  plan check for power and energy, warehouse.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15880	17041-10000-15913	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.06664	-118.46903	PC FOR POWER FOR TEMPORARY POWER TO NEW SCHOOL BUILDING.TEMPORARY SERVICE PROVIDED BY DWP FOR 1200A DISTRIBUTION BOARD. SCOPE INCLUDES FEEDING EXISTING DISTRIBUTION EQUIPMENT AND ASSOCIATED WIRING. ALSO FEEDING CONSTRUCTION PANEL (LOADS ON CONSTRUCTION PANEL ARE NOT PART OF THE SCOPE OF THIS PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15881	16041-10001-08316	801 S HOPE ST UNIT B	90017	14	129A209   268	5144020200	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.04656	-118.25938	4/13/2016 Changes to an approved set of plans. Changes under delta 2, changes include reduction from 75KVA Xmr to 45KVA.(((FIRST TENANT IN COMMERCIAL SPACE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15882	15041-10000-05983	10345 W PICO BLVD 204	90064	5	129B161   391	4315014014	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM			PC Approved	03/02/2015 12:00:00 AM	ADDRESS	34.04761	-118.41527	T.I. WORK- CONVERSION OF AN OPEN SPACE TO SMALL CLASSROOMSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15883	17041-20000-17587	18025 W PARTHENIA ST	91325	12	195B125   776	2768010016	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.2288	-118.52592	PV1. ADDITION OF 8.4KW TO EXISTING SYSTEM. LINE SIDE TAP. TOTAL SYSTEM 15KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15884	15041-20000-04509	3743 S MIDVALE AVE	90034	5	117B161   645	4252025007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			02/17/2015 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.01737	-118.41181	PLANCHECK FOR POWER AND ENERGY FOR NEW APARTMENT BUILDING . FIFTEEEN UNITS. 18 PARKING SPACES IN SUBTERRANEAN GARAGE 4 STORIES W/ ROOF DECK. FIRE ALARM VARIANCE HAS BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15885	18041-20000-35459	314 S GLENROY AVE	90049	5	135B145    63	4366020008	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.06999	-118.46033	Plan check for PV roof mounted system, system size: 12.87kW DC 39 PV modules and 1 inverter(11.4kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15886	15041-20000-36025	16030 W VENTURA BLVD	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM			PC Info Complete	11/12/2015 12:00:00 AM	ADDRESS	34.15598	-118.48247	Replacing  Emergency Stand  by  Generator 60kW witha new Generator 150kW and (2) new ATS < 200 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15887	16041-20003-41865	7556 N HESPERIA AVE	91335	3	186B125   213	2120021003	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.2081	-118.5261	6/12/2017changes to an approved set of plans.  changes include new silfab SLG345M MODULES and updated plans to reflect field conditions.  this is plan check only.  (((((Plan check for a PV2 roof-mounted PV system. System size is 12.6 kWac and consists of (45) modules, (45) micro-inverters, and (1) load center.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15888	11041-20000-24482	818 W 7TH ST Ste 860	90017	9	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.04895	-118.25943	T.I.  Existing offices.  Remodel of the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15889	19041-10000-09333	8949 N LINDLEY AVE	91325	12	195B125   257	2769015034	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.23316	-118.52753	PV1. PC FOR NEW ROOFTOP SOLAR SYSTEM CONSISTS OF 25 MODULES (Q-CELL 305), 25 OPTIMIZERS (SE P320) AND 1 INVERTER (SE7600H-US). SYSTEM SIZE IS 7.625kWdc AND 7.6kWac. PANEL UPGRADE (125A to 200A) TO BE PERMITTED ON A SEPERATE PERMIT (EXPRESS)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15890	19041-10000-25113	5552 W CENTURY BLVD	90045	11	090B173   137	4129029022	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	33.94522	-118.37789	supplement to 19041-10000-15494 change under delta 5 . change include removing one panel and rearanging homeruns.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15891	17041-30000-31292	4574 S CENTINELA AVE	90066	11	108B157   887	4232026048	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.99165	-118.42143	Plan check for Title 24 only in existing space T.I. Coffee shop new  lighting and receptacle. Total area: 732 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15892	11041-10001-16986	615 N SANFORD AVE	90744	15	030B209   447	7424019042	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	33.77816	-118.25068	previous plan check expired. resubmittal with original set of plans. applicant to provide evidence that hay press is a listed piece of equipment. then recalculate fees. pc for power. SERVICE UPGRADE TO 1200 AMPS IN AN INDUSTRIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15893	15041-20000-02948	15963 W YARNELL ST	91342	7	228B141   182	2603009024	C2-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Closed	04/17/2017 12:00:00 AM	ADDRESS	34.32212	-118.47947	"Plan check for energy only. Change of use from office to restaurant. TI, including a new lighting system (w/emergency lighting). 979sqft. ""COMPLY WITH DEPARTMENT ORDER effective date 10/22/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15894	12041-20000-08407	13316 W VALLEYHEART DR	91423		165B157   476	2360012014	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks			Electrical	Electrical	Apartment			04/12/2012 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.14929	-118.42304	New 26 unit apartment. 4 story apartment. Plan check for power and energy. 24342 conditioned sqft, 579 unconditioned sqft. Variance for fire alarm is on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15895	11041-10000-02685	12730 S FIGUEROA ST	90061	15	081B201   254	6132019042	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	33.91687	-118.28256	First time tenant for a new Market & Restaurant. EPC is for power & Energy. (core & shell plans were permitted under 09041-10000-12623.) permit was obtained on express permit on 10041-10000-22738	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15896	19041-10000-16066	5541 E YORK BLVD	90042	14	154-5A227  12	5478025001	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM			PC Approved	05/01/2019 12:00:00 AM	ADDRESS	34.11959	-118.19683	TI in a new Bar / Restuarant. Installing New Lights. T-24 Energy Only.Building Permit: 18016-10000-38382	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15897	17041-10001-44422	5027 N MONTEZUMA ST	90042	1	151-5A225  52	5469009037	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.11101	-118.20559	CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE INCLUDES CHANGES  TO MODULES SIZE FROM 295 TO  305.SYSTEM SIZE REMAIN THE SAME DUE TO USE OF OPTIMIZERS. THIS IS PLAN CHECK ONLY. PERMIT FEES PAID UNDER FINAL. NEW ROOFTOP SOLAR SYSTEM WHICH CONSIST OF 14 MODULES(Q.PEAK-G4.1 295),OPTIMIZERS (SOLAREDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE3800H-USRGM)SYSTEM SIZE IS 3.8KWac AND 4.48KWdc	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15898	17041-10000-04636	20215 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.27499	-118.57438	PC FOR ENERGY. NEW BUILDING S4 ,  -SHELL ONLY  1 STORY COMMERCIAL BLDG , SERVICE SIZE 400A , 277/480 V, TOTAL AREA 1619 SQ FT.B# 16010-10000-06144	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15899	16041-20000-41157	11100 N SCOVILLE AVE	91040	7	210B189    61	2551019006	RA-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	PIN	34.2710718	-118.31390494	Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 60A subpanel fed from a 400A split bus panel.  10kW ungrounded system. (30) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15900	16041-10001-44999	10250 W SANTA MONICA BLVD STE. 1395	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Info Complete	09/19/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Suppemental plan check and permit, 1st changes to approved plan on Tenant ""Midici"" Ste. 1395.  Changes noted as delta-1:SHEET E3.0: UPDATED FLOOR POWER FLOOR PLAN PER LOAD SCHEDULE UPDATESHEET E5.0: ELIMINATED EXHAUST FAN EF-1 & EF-2. NEW FC-3 & EF-5 10. SHEET E-5.1: ROOF TOP EQUIPMENT EF-1 & EF-2 ELIMINATED & EXHAUST FANS SCHEDULE UPDATED. SHEET E7.0: PANELS UPDATED"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15901	19041-10000-15372	12665 W VILLAGE LANE	90094	11	102B161  1259	4211034106	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/25/2019 12:00:00 AM			Corrections Issued	04/25/2019 12:00:00 AM	ADDRESS	33.97786	-118.41484	PC FOR T24 ONLY, SCOPE INCLUDES NEW LIGHTING, RECEPTACLES, AND CONTROLS.  TOTAL AFFECTED AREA IS 371 SQFT. ((REMOVE 3 PARKING SPACES AND CONVERT PORTION OF GARAGE TO STORAGE ROOM.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15902	12041-20000-10035	2134 N VERMONT AVE	90027	4	150B197    99	5590004021	R3-1	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM			PC Approved	05/02/2012 12:00:00 AM	ADDRESS	34.11083	-118.29161	energy plan check market gas station	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15903	17041-10000-11638	5614 S FIGUEROA ST	90037	9	108B201  1055	5001036046	C2-1VL	South Los Angeles	Southeast Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	33.991	-118.28247	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 35700 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15904	17041-20001-43164	1400 N MARTEL AVE 1-33	90046	4	147B181   939	5550019072	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.09611	-118.35052	expeditepv2install roof mounted pv system sized 25kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15905	11041-10000-20654	1017-1023 E ELKGROVE AVE BLDG 41	90291	11	111B145   625	4243003039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.0007	-118.45939	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15906	18041-10000-26999	2945 S MINER ST	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	08/28/2020 12:00:00 AM	ADDRESS	33.71621	-118.27584	$0 due to Senate Bill 1222. NEW 1167.9 KW PV SYSTEM MOUNTED ON CARPORTS WITH 2685 PV MODULES AND 32 INVERTERS WITH 480 VOLT OUTPUT. <<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03429	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15907	12041-20000-20565	11090 W SANTA MONICA BLVD	90025	5	129B153   858	4323020037	C2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	34.04751	-118.4439	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15908	17041-10000-10198	5142 N VAN NUYS BLVD	91403	4	171A151    80	2248009004	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.16414	-118.44848	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 5000 SQ FT. INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15909	19041-10000-03282	1115 W 190TH ST	90248	15	060B197   543	7351028010	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	10/26/2020 12:00:00 AM	ADDRESS	33.85849	-118.29527	FULL PLAN CHECK FOR THE 1ST AND 2ND FLOOR OF A 2 STORY BUILDING T.I, CHANGE OF USE FROM AUTO REPAIR TO HYDROPONIC AGGRECULTURAL ENTERPRISE. SCOPE INCLUDES A NEW 120/208V 3-PHASE 800-AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15910	14041-20002-05380	1999 W ADAMS BLVD	90018	8	123B193   477	5058015005	[T][Q]C2-2D	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM			PC Approved	01/23/2015 12:00:00 AM	ADDRESS	34.03285	-118.30872	REVISIONS TO AN APPROVED SET OF PLANS.  RELOCATION OF SWITCHGEAR NOTED ON PLANS BY DELTA 15.PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. ELECTRICAL UPGRADES TO THE GOLDEN STATE MUTUAL LIFE INSURANCE BUILDING. BUILDING PERMIT # 14016-10000-03610   TENANT IMPROVEMENTS, WILL NOT CHANGE THE BUILDING OCCUPANCY OR OCCUPANT LOAD AND WILL NOT ALTER THE HISTORIC CHARACTER OF THE BUILDING.  see comments.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15911	17041-10000-02654	12927 W EUSTACE ST	91331	7	216B161   644	2527006007	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.28472	-118.41429	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.25KWac. (37)MODULES-LG300N1K-G4(37)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15912	18041-10001-48205	10630 N SEPULVEDA BLVD	91345	7	207B145   393	2649011043	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.26357	-118.46694	**expedited per applicant**Install New rooftop solar system on a commercial building. System size 50 kW AC / 45.88 kW DC. (1) 20 kW central inverter, (1) 30 kW central inverter, (133)  modules, (67) P730 optimizers, (2) 30 kVA transformers. (E) MSP is 600A, 240/120V, 3ph, 4W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15913	16041-10001-23235	2030 W 8TH ST	90057	1	132A203   260	5141020017	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM			PC Approved	11/14/2016 12:00:00 AM	ADDRESS	34.05466	-118.27766	11/14/16Changes to an approved set of plans. All changes are made under delta 2 and delta 4. Changes include adding/relocating lighting fixtures, and revising panel schedules. Note: Permit is paid under PCIS#16041-10000-23235((((((T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING  COMMERCIAL BUILDING (7 ELEVEN).SCOPE INCLUDES NEW PANELS NEW RECEPTACLES AND NEW LIGHTS. TOTAL EFFECTED AREA IS 4175 SQFT (INDOOR AND OUTDOOR).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15914	16041-10000-15712	13035 PORTOLA WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	PIN	34.31120672	-118.40409465	PV1 NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOFTOP. SCOPE INCLUDES 20 SOLAR PANELS. ALSO INCLUDES 20 OPTIMIZERS AND 1 INVERTER. TOTAL SYSTEM SIZE IS 5.2 KW DC SOLAR SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15915	12041-10001-06481	300 S DOHENY DR	90048	5	138B169   549	4335015050	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.07343	-118.38954	REVISION TO APPROVED PLANS. RELOCATE TWO HEATERS FROM WG2 PANEL TO PANEL WG3. WG2 OCPD 200A ON 225A BUS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15916	19041-10000-34204	19415 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	11/24/2020 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.18705	-118.55558	Energy plan check for a retail (O'Reilly auto parts) T.I. located in a single story building. Scope includes new lighting and equipment with a total lighting area of 6,909-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15917	18041-10001-00539	15355 W MULHOLLAND DR	90077	4	159B145   557	2279027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.12978	-118.4678	CHANGE TO APPROVED SET TO REFLECT FIELD CONDITIONS. SCOPE INCLUDES RELOCATION OF ESS'S DICONNECTS. THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15918	10041-20000-12955	7680 N CLYBOURN AVE	91352	2	186B177   576	2466029049	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM	07/21/2010 12:00:00 AM		Permit Finaled	07/26/2010 12:00:00 AM	ADDRESS	34.20998	-118.36327	Lighting in the warehouse. This plan check for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15919	16041-20000-17067	9075 N GLENOAKS BLVD	91352	6	195B173    87	2408032***	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.23374	-118.37084	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISITNG HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQUARE FOOTAGE 4288.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15920	14041-20000-27307	6400 N CANOGA AVE	91367	3	180B105    61	2149001020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Expired	10/27/2016 12:00:00 AM	ADDRESS	34.18665	-118.5972	TI TO AN EXISTING COMMERCIAL BUILDING SUITE NO. 200.  RELOCATION OF LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15921	13041-20000-01972	6407 W SUNSET BLVD	90028	13	147A187   135	5546012011	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			PC Approved	02/02/2013 12:00:00 AM	ADDRESS	34.09815	-118.32896	T-24 and emergency lighting plan check for EXTERIOR REMODEL OF RESTAURANT - FACADE/ AWNING/ PARAPET.  Signs are not included with this plan check.  Installation appears complicated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15922	11041-20000-19764	1015 W WILSHIRE BLVD 2ND FLR	90017	1	130-5A207 136	5143026017	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.05174	-118.26166	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING 2ND FLR OFFICE TENANT IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15923	15041-20000-14772	215 N GAFFEY ST	90731	15	018B197   891	7451005023	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	33.74441	-118.29256	Plan check for power and Title-24 (energy).  Total area = 3,306 (indoor) + 3,329 (outdoor)  T.I. to existing restaraunt space.  Complete new electrical distribution system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15924	13041-10001-24499	19330 W PLUMMER ST	91324	12	198B117    73	2761037001	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Public Safety Only			10/02/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.2426	-118.55515	RELOCATED FA PANEL AND ADDED REMOTE ANNUNCIATORNEW FIRE ALARM SYSTEM , CENTRAL STATION MONITORING TO BE INSTALLED IN ROSS. 1 PANEL, 32 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15925	19041-30001-15337	601 S FIGUEROA ST Suite 3650	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	05/02/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Lighting floor plans have been revised and changes have been reflected on the Title 24 compliance forms.*****Original Work Description*****Plan check for Title 24 only. Project site is an existing suite on the 36th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 3,650 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15926	13041-20000-02318	12111 W SANTA MONICA BLVD	90025	11	126B145   659	4263028050	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	03/05/2013 12:00:00 AM	ADDRESS	34.04058	-118.46387	Change to lighting and receptacles to a music classroom space.  Load is less than 400 amps and occupancy load is less than 99 per the applicant.  PLAN CHECK ONLY for Energy.  NO Emergency lighting per applicant.  Permit Fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15927	16041-20000-34027	11140 N JELLICO AVE	91344	5	210B129   234	2711013002	R1-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.27352	-118.51791	pv1install roof mounted pv system sized 9.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15928	19041-20000-08567	12313 N FINCH ST	90039	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	PIN	34.3012906	-118.58563914	PV1.  Install 5.03 kW roof mounted grid tied PV system.  (15) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15929	16041-10000-43279	1544 E WASHINGTON BLVD	90021	9	118-5A213 368	5129012015	M1-1, M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.02106	-118.24485	PC for enrgy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total sqft: 54350	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15930	10041-30000-08935	1394 S MIDVALE AVE	90024	5	132B153   865	4324009013	[Q]R4-1L	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Apartment			05/13/2010 12:00:00 AM			PC Approved	05/13/2010 12:00:00 AM	ADDRESS	34.05505	-118.44268	INSTALL 22 LIGHT FIXTURES. PEMIT ALREADY OBTAINED IN APPLICATION # 10041-30000-07316. THIS P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15931	14041-20000-33776	16850 W CATENIA PL	91344	12	216B133   103	2609023030	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.29156	-118.49967	pv1install roof mounted pv system sized 6.0kw interconnected with msp.(18) sunpower spr-x21-345 modules(1) sunny boy 6000 tl inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15932	18041-20000-17310	8527 N HAZELTINE AVE	91402	6	192B153   114	2638016020	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.22606	-118.44108	Plan check for a roof-mounted PV system. System size is 3.2 kWac and consists of (14) modules and (14) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15933	11041-10000-02687	515 S FIGUEROA ST 20th floor	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Finaled	05/18/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	Ti in a corridoor of a highrise building. EPC is for T24 & Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15934	18041-10000-05380	6601 S CENTER DR WEST	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	33.97997	-118.39375	PC FOR TITLE 24 ENERGY ONLY FOR TENANT IMPROVEMENT OF EXISTING LOBBY  WITH OUTDOOR LIGHTING IN CAMPUS STYLE.TOTAL AFFECTED AREA 2875+2992 SQ.FT  (INDOOR AND OUTDOOR)SCOPE INCLUDES NEW LIGHTS, RECEPTACLES AND EQUIPMENT. B# 17016-10000-36288	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15935	18041-10000-28817	25100 S NORMANDIE AVE E	90710	15	036B197   149	7413008007	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Issued	08/16/2018 12:00:00 AM	ADDRESS	33.79648	-118.29726	PLAN CHECK FOR TITEL 24 ONLY FOR - Tenant improvement on existing warehouse. TOTAL AFFECTED AREA = 2306 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15936	16041-20000-18045	670 S KELTON AVE	90024	5	135B149   492	4363014010	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.06486	-118.45263	New fire alarm system in (N) 5 story apartment building over 2 levels subterranean parking garage.  (184) fire alarm devices with FACP and annunciator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15937	19041-20000-35959	7655 W CURSON TER	90046	4	150B177   375	5551010040	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Issued	11/13/2019 12:00:00 AM	ADDRESS	34.10491	-118.35659	600A 240/120V 1ph-3w service, distribution, power, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15938	19041-20000-47426	2317 N RICHLAND AVE	90027	4	153A201   107	5592025025	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.11436	-118.28252	27 kWh energy storage system and associated distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15939	17041-10000-37830	7418 W APPERSON ST	91042	7	204A197    44	2558024039	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.25579	-118.29385	T-24 ONLY, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 7095.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15940	15041-10000-34385	707 W WILSHIRE BLVD STE 3125	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1967.  SCOPE OF WORK IN SUITE 3125.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15941	15041-10000-38670	2632 S GRAND AVE	90007	9	121-5A205 251	5122013006	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.02563	-118.27263	TI TO OFFICES and WAREHOUSE. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15942	12041-10001-07169	2528 W OLYMPIC BLVD #110 & 111	90006	1	130-5A201 138	5076007036	C2-2	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.05226	-118.28483	Modification to previously approved set for lighting change only.  PLAN CHECK ONLY for Energy.           <<<<NEW DENTAL OFFICE IN SUITE #'S 110 & 111. PLAN CHECK FOR POWER & ENERGY.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15943	14041-20001-29273	10678 W KURT ST	91342	7	213B177    91	2529016010	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM			Reviewed by Supervisor	10/31/2014 12:00:00 AM	ADDRESS	34.2787	-118.36364	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 6.45KW AC USING MICROINVERTER SYSTEM. USING 2 STRINGS. USING ENPHASE M215. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15944	17041-10000-17973	12178 W VENTURA BLVD	91604	2	162B165   199	2369004045	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Issued	08/21/2017 12:00:00 AM	ADDRESS	34.14309	-118.3978	PC FOR TI (Change of use from (e) retail to beauty salon) FOR TITLE -24 ENERGY ONLY. TOTAL AFFECTED AREA  1815 SQ.FT.SCOPE INCLUDES NEW LIGHTS, RECEPTACLES AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15945	16041-10000-01609	640 E VERNON AVE	90291	11	111B145  1275	4239003014	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Expired	02/14/2018 12:00:00 AM	ADDRESS	33.9974	-118.46868	INSTALL 3.445 KW DC ROOF-MOUNTED SOLAR ARRAY OBN A SINGLE FAMILY HOUSE.(13) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15946	17041-10000-08967	10610 N OWENSMOUTH AVE	91311	12	207B105   317	2722036029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Issued	03/21/2017 12:00:00 AM	ADDRESS	34.26306	-118.60152	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 21700 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15947	17041-10000-17168	4601 N VAN NUYS BLVD	91403	4	168A151   155	2265012001	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.1549	-118.44889	PC for energy only, Indoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 3,450 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15948	14041-10001-33492	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM			PC Approved	01/26/2015 12:00:00 AM	ADDRESS	34.08269	-118.24139	Change to approved set by adding on a 20Hp fire pump and and a 2Hp jockey pump; permit under original plan check.per F.Y(((Plan check per applicant request : Power plan check for a New 400-Amp electrical service for domestic water pumps))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15949	19041-10000-42263	3501 S CENTRAL AVE	90011	9	115-5A209 121	5114014033	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM			Reviewed by Supervisor	12/04/2019 12:00:00 AM	ADDRESS	34.01152	-118.25676	NEW FIRE ALARM SYSTEM. SCOPE INCLUDES 141 FA DEVICES AND 2 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15950	14041-20000-16979	11980 W SAN VICENTE BLVD B106	90049	11	129B141   232	4265007052	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	34.05208	-118.47215	Plan check only for TI to exercise rooms in (E) highrise medical center.  Title 24 for changes to existing lighting system.Permit obtained previously under 14041-30000-16342	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15951	17041-20000-26323	16628 W KNAPP ST	91343	12	198B137   703	2687021011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Issued	11/28/2017 12:00:00 AM	ADDRESS	34.23822	-118.49484	PV1.  Install 2.0 kW PV system with energy storage system.  (2) modules with 2kW rated inverter and battery system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15952	16041-20000-01971	10250 W CONSTELLATION BLVD Floord 31--35	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for power and energy. Adding new lighting including emergency. Total sqft. 70,100. EARLY START INTERIOR DEMOLITION OF (E) OFFICE FLOORS (LEVELS 31-35) LEVEL 31 (4003 S.F.). LEVEL 32 (19, 501 S.F.). LEVEL 33 (19, 489 S.F.). LEVEL 34 (19, 508 S.F.). LEVEL 35 (19508 (S.F.).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15953	15041-10000-31657	9031 N LURLINE AVE	91311	3	195B109   477	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.23463	-118.58443	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1331.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15954	17041-20000-32720	1050 W CHILDS WAY B17G	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.02262	-118.29103	Plan check for energy only. TI to lab in commercial building. New lighting - 385 sq. ft.Electrical permit pulled under application #17041-90000-23321.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15955	12041-10000-03364	825 S BLOOM WALK 4th-5th Floor	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	PIN	34.02192429	-118.28551249	Plan check T24 Energy/Emergency lighting for TI on the 4th and 5th floor. Office, Restroom, and Lab remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15956	19041-20000-12821	17755 W ALONZO PL	91316	5	165B129    33	2182025011	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.15233	-118.52	addition of (1) tesla ESS 5KW to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15957	18041-30001-10273	4020 S LINCOLN BLVD Space D	90292	11	108B149  1249	4230002013	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Issued	03/29/2018 12:00:00 AM	ADDRESS	33.99001	-118.44704	03-29-2018 Changes to an approved set of plan. Changes include added daylight sensors and show window receptacles. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15958	19041-20001-34607	9930 N OWENSMOUTH AVE NO 9	91311	12	201B105    38	2747014***	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.25082	-118.60153	PV1. INSTALL 7.8 KW DC PV SYSTEM WITH (24) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600)NOTE: INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-34607	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15959	11041-20001-25581	6110 N VAN NUYS BLVD	91401	6	177A151    28	2240006010	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM			PC Approved	05/03/2012 12:00:00 AM	ADDRESS	34.18104	-118.44846	Revision of lighting to approved plans under 11041-20000-25581. Change from fluorescent to metal halide lighting under service canopy. 2096 outdoor (hardscape) area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15960	12041-10000-15397	351 E SUNSET AVE	90291	11	109-5A143 577	4286006036	[T][Q]CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	33.9959	-118.474	Plan check for emergency lighting only.  Permit is for one circuit for Emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15961	12041-20000-14139	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	09/14/2012 12:00:00 AM	ADDRESS	34.01925	-118.37654	Add UPS unit for equipment.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15962	18041-10000-10934	970 W FRANCISCO ST	90502	15	057B197    68	7351034066	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.84824	-118.29298	PLAN CHECK FOR TITLE 24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15963	11041-20000-26875	2760 N CLARAY DR	90077	5	156B149    56	4379005***	RE15-1-H-RPD	South Valley, West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Public Safety Only			12/16/2011 12:00:00 AM	12/16/2011 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	34.12306	-118.44796	Fire Alarm system for Clubhouse	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15964	19041-20000-18173	7605 N HAZELTINE AVE	91405	2	186B153    66	2215001004	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	07/17/2020 12:00:00 AM		Permit Finaled	11/21/2020 12:00:00 AM	ADDRESS	34.20827	-118.44027	TI REMODEL OF EXISITNG LOW RISE COMMERCIAL BUILDING. T24 INCLUDED. TOTAL SQUARE FOOTAGE = 11,038SF. SCOPE OF WORK ALSO INCLUDES (2) 45 KVA TRANSFORMERS, (5) 225A PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15965	14041-20000-22699	7040 N DEVERON RIDGE ROAD	91307	12	183B089   303	2028046033	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.19812	-118.64787	PV1.  Install 7.54 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15966	18041-20000-02474	7343 N RESEDA BLVD	91335	3	186B125   738	2118015003	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.20424	-118.53632	Plan check for a fire alarm system for a 40-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, (4) power supplies, and (161) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15967	16041-20000-31731	1843 N ALEXANDRIA AVE	90027		150B197   981	5589034018							Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM	ADDRESS	34.10473	-118.29879	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.4KW INTERCONNECTED WITH MSP.THIS IS PLAN CHECK ONLY.PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-90000-30895	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15968	18041-10000-14391	767 S ALAMEDA ST 330	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Approved	04/25/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	PLAN CHECK FOR T24 ONLY, OFFICE TENANT IMPROVEMENT AT EXISTING OFFICE SPACE. TOTAL AREA PER T24 INFO: 20,074 SQ.FT ((verify this info since lighting floor plan SOW only includes meeting room, office room, and accounting))((B# 18016-10000-11732))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15969	19041-20000-14460	5544 N BONNER AVE 5	91601	2	174B173  1094	2350005051	R4-1L	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Apartment			04/19/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.17122	-118.37401	PLAN CHECK FOR NEW 4-STORY, 5-UNIT APARTMENT BUILDING 10,714 SQ FT WITH GARAGE @ GRADE. 2 TYPICAL UNITS. 600A SERVICE W/600A PANEL, (5) 125A UNIT PANELS, A 100A EV PANEL, AND 150A HOUSE PANEL. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 5849SFB#19010-10000-00239	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15970	12041-10000-07523	1230 S MENLO AVE	90006	1	129B197   936	5076019031	R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			04/02/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.04815	-118.29051	Plan check for 44.16KW roof mounted Enphase M215 Microinverter photovoltaic system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15971	12041-10000-26588	1406 W MANCHESTER AVE	90047	8	097-5A195 289	6037015028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	33.95984	-118.30079	New building. PROPOSED MCDONALDS RESTAURANT. NEW 1000A SERVICE. 41917 SF. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15972	10041-10000-24463	1430 N SUNSET PLAZA DR	90069	5	147B169   902	5559011020	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2010 12:00:00 AM	01/25/2011 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	34.096	-118.38195	New 600 Amp service for a single family. Nwe panel boards, circuits and equipments. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15973	16041-10001-33847	643 N FAIRFAX AVE	90036	5	141B177   778	5527017007	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.08285	-118.36169	Change to approved set by updating the utility fault current, all the fault current calculation, and main switchgear.(((PC FOR POWER AND ENERGY. NEW 63 UNITS APARTMENT BUILDING,  4-STORY, ONE LEVEL GARAGE AND ONE SUBTRANIAN LEVEL. 12-TYPE UNITS.SERVICE SIZE 1600A, 208/120 V 3 PHASE 4 WIRE. TOTAL AREA 59011 SQ FT.BUILDING APPLICATION 16010-10000-02964)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15974	15041-10002-05481	600 WORLD WAY TERMINAL 6-LV.3 #622	90045	11	087B165    13	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	CHANGES TO AN APPROVED SET. NOTE CHANGES IN DELTA 9.(((CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES IN DELTA 8. )))(((TI TO AN EXISITNG SINGLE STORY COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 942)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15975	19041-20000-42383	100 S LAUREL AVE	90048	5	138B177   591	5511023027	R1V3	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.0741	-118.36462	PV1. INSTALL 7.26 KW DC PV SYSTEM WITH (22) MODULES/MICROINVERTERS (ENPHASE 1Q7X)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15976	16041-10000-29628	10319 N NORRIS AVE	91331	7	204B165   115	2537004029	[Q]M1-1-CUGU, [Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.25712	-118.40313	Plan check Title 24 only in existing space office T.I. Existing lighting fixture add new receptacles and alter lighing control. Total area: 1,187 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15977	16041-10000-39527	4431 S 10TH AVE	90043	8	111B185   174	5013024013	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.00277	-118.32827	PV1 roof mounted soalar system installation to  a single family home. Installing 36 microinverters ENPHASE M250-60-2LL-S22 for a total system size of 9.0KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15978	19041-20000-01995	1111 N CHAUTAUQUA BLVD	90272	11	129B129   348	4423008031	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.05014	-118.51774	Install 13.5 kWh energy storage, backup gateway, critical load backup panel, and 225A main service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15979	14041-10000-25139	19346 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.23298	-118.55494	New tenant improvement to existing currently undeveloped suite at existing building for medical urgent care office. Not high rise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15980	13041-20000-21586	4614 N MIRADOR PL	91356	3	168B121   470	2176032011	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Expired	10/06/2015 12:00:00 AM	ADDRESS	34.15412	-118.54778	PV1 10.92 KW NEGATIVELY GROUNDED SYSTEM. 42 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15981	13041-10000-04211	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			02/19/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.06209	-118.34912	Plan check power and energy for 125 residential units and 50 joint/live work units apartment building over three level basement parking garage. 5000A service supplying building. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15982	17041-10000-13213	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.14441	-118.39252	Plan check for power.  Disconnect existing power and provide new cooling tower, exhaust fans, and chillers.  Total new load exceeds 400 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15983	19041-20000-30973	13165 W DEL SUR ST	91340	7	216B157    65	2524004007	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.28516	-118.41972	Plan check for PV roof mounted with Energy storage system, PV System size: 3.15KW with 10 PV Modules  and 1 inverter(3.0KW), Tesla Battery PowerWall 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15984	13041-20000-09832	18555 W VENTURA BLVD	91356	3	174B125   543	2160007012	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.1697	-118.53779	New panels, circuits, and lighting for an existing Medical Clinic.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15985	11041-20001-20034	11868 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/03/2011 12:00:00 AM	ADDRESS	34.28596	-118.50158	PLAN CHECK ONLY. REVISION TO APPROVED PLANS. REVISE T24 CALCULATION FOR ADDITIONAL LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15986	10041-10005-03249	7333 W WORLD WAY 4th FL	90045	11	090B161    67	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM			PC Approved	03/23/2011 12:00:00 AM	PIN	33.94534804	-118.41786236	THIS IS A SUPPLEMENTAL TO 10041-10000-03245.  THEY ARE REMOVING THE DIMMABLE RELAY TO THE EMERGENCY LIGHTS.<<<<<<<<<TI for offices on the 4th floor of the existing LAWA Admin Building.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15987	16041-30000-29862	13023 N BARTO DR	91344	12	222B133   171	2602009028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.30631	-118.50911	Plan check for PV roof mounted system. system size: 6.0kW with 27 modules and 1 inverter(6.0kw) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15988	12041-10000-21208	5247 N AUCKLAND AVE	91601	4	171B177   433	2417004019	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.16622	-118.36067	ROOF INSTALLATION OF 4.68KW PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15989	15041-20000-33429	4744 N YARMOUTH AVE	91316	5	168B129   455	2182023007	RA-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			Reviewed by Supervisor	10/23/2015 12:00:00 AM	ADDRESS	34.1568	-118.51982	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (25) modules, and (1) combiner box. Main service panel size is 400 amps.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
15990	19041-20000-18484	7174 W MELROSE AVE	90046	5	141B181   637	5525015024	C2-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	04/30/2021 12:00:00 AM	ADDRESS	34.08333	-118.34596	Plan check for power and energy. Project site is an existing commercial building. Project scope is tenant improvement to a restaurant. Work includes a new 800 amp service and a total lighting area of 4,887 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15991	18041-20000-21701	17000 W FLANDERS ST	91344	12	213B133   566	2607019019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.28018	-118.50304	PV1.  Install 10.695 kW roof mounted grid tied PV system. (31) AC modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
15992	13041-10000-19968	8117 W SUNSET BLVD	90046	4	147B177   996	5555031016	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.09814	-118.36591	TI FOR RESTAURANT ; PLAN CHECK FOR POWER AND ENERGY IN A HOTEL/MOTEL. RELOCATING AN 1600 A PANEL AND DIMMER PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15993	13041-20003-06945	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Info Complete	10/15/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	CHANGES TO SITE LIGHITNG. ADDED LIGHTING. PC FOR T24 CHANGES AND ADDITION OF NEW CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15994	15041-20000-09339	1999 S AVENUE OF THE STARS Suite 3100	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.05886	-118.41642	Title 24 plan check only.  Total area = 10,347 sq. ft.T.I. to existing commercial highrise office space.  380 A of new installed load.  Space is not to be used by a first time tenant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15995	14041-20000-33555	6111 W MULHOLLAND HWY	90068	4	159B189    42	5581015014	RE9-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.13043	-118.32138	PV1MICROINVERTER STANDARD PLAN SYSTEM SIZE 8.4KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
15996	19041-20001-36657	6241 N GLADE AVE	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.184	-118.60789	Expedite per applicant requst. Plan check for Pv roof mounted system, PV system size: 23.49KW DC, 20.9KW AC CEC with 54 PV Modules and 2 inverters(9.0KW)Applicant reques: %%%%%%%%%%      Plan stay Van Nuys    %%%%%%%Note: This is 12 Buildings on 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
15997	12041-20000-07795	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	TI for office. 1265 conditioned sqft. Plan check for energy and emergency lighting. Commercial high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15998	10041-20000-19814	10899 W WILSHIRE BLVD	90024	5	132B153   290	4363022019	[Q]C4-2-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	ADDRESS	34.05906	-118.44376	Plan check T24 Energy general and emergency lighting for Hammer Museum	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
15999	17041-20000-26144	20154 W ADELE DR	91364	3	168B113   377	2174002022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.15549	-118.57292	Plan check for solar pv system, roof-mounted on SFD.9kW ungrouded system. (33) 325W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16000	18041-10000-16626	1370 N ST ANDREWS PL	90028	13	147A193   187	5544030056	(Q)C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.09641	-118.31076	PC FOR POWER AND ENERGY FOR  REMODEL OF EXISTING TWO STORY BUILDING AND BASEMENT.  WORK INCLUDES 60 PODS ON GROUND FLOOR. NEW SERVICE 2500A 480/277 V TOTAL AFFECTED AREA 97293 SQ.FT B #18016-10000-04168	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16001	16041-10000-03756	11100 W SANTA MONICA BLVD	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Info Complete	02/02/2016 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI, add 10 bollard lighting fixtures to an (E) pedestrian pathway using (E) site lighting ckt. PC for T-24 only. Total outdoor area: 751 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16002	19041-10000-04650	6600 N TOPANGA CANYON BLVD 1032	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			Corrections Issued	02/07/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TITLE 24 ONLY FOR CHANGE OF USE FOR SUITE 1032 (RETAIL M  TO OFFICE B) AND 2245 SF  TENANT IMPROVEMENT; REMOVAL OF NON STRUCTURAL PARTITIONS, NEW PARTITIONS, NEW FIXTURES, NEW SUSPENDED CEILING, STRUCTURAL STEEL FRAMING FOR NEW INTERIOR STOREFRONT AND INSTALLATION OF NEW INTERIOR STOREFRONT - TOTAL AFFECTED AREA = 1941 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16003	19041-30000-16981	1153-1159 N CYPRESS AVE	90065	1	145-5A219  22	5454025011	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.09487	-118.22707	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a core and shell. Total lighting area = 5,406 sq. ft.Note: Building permit has been issued under 17016-10000-34307. Tenant improvements shall be under separate permits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16004	17041-20002-34876	7107 N PENFIELD AVE	91306	3	183B113   195	2135009027	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.19947	-118.56893	10/13/2017 Changes to an approved set of plans. Changes have been made to the PV system. There has been an addition of (4) modules for a revised module count of (35) modules and an updated system size of 12.1 kWac.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 10.7 kWac and consists of (31) AC PV modules and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16005	18041-20001-00541	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM			PC Approved	07/16/2018 12:00:00 AM	ADDRESS	33.87528	-118.29083	7/16/2018changes to an approved set of plans.  changes to reflect field conditions.this is plan check only.  (((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR THE 5TH FLOOR. BUILDING PERMIT # 17016-10000-34372)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16006	13041-20000-21628	6110 S HOOVER ST	90044	9	105B201   778	6004024029	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM			Reviewed by Supervisor	09/17/2013 12:00:00 AM	ADDRESS	33.98373	-118.28686	Plan check for power and energy. TI for a laundromat. Applicant would like corrections emailed to them via rolandtorres18@yahoo.com. <<<<<PROJECT IS ON HOLD>>>>>Exdpedited fee $1,582.70 was approved to be refunded 10/29/13 by elie maalouf	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16007	13041-10000-04656	1250 N NORTH MAIN ST LAX-C	90012	1	135A217   138	5409010032	[Q]M2-1	Central	Central City North			2060.10	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.0641	-118.23218	New warehouse building. Suite # LAX-C.  Plan check for Power & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16008	17041-10000-18546	3465 W 6TH ST 180	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.06373	-118.29761	PC FOR TITLE 24 FOR TENANT IMPROVEMENT TO EXISTING RETAIL SPACE. ENERGY ONLY.  TOTAL AFFECTED AREA 874 SQ.FTINSTALLING NEW LIGHTS AND RECEPTACLES.BL# 17016-10000-08853	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16009	16041-10001-23662	57 E MARKET ST	90291	11	108A143   429	4226007009	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM			PC Approved	09/23/2016 12:00:00 AM	ADDRESS	33.98811	-118.47335	09/23/16Changes to an approved set of plans. Changes include replacing the HANWHA Q-CELLS.PEAK-G3 280 modules with SOLARWORLD SW280 MONO modules and relcating the inverter on the roof.  ((((((Installation of a roof mounted solar system to a commercial site. Installing a cetral inverter rated at 7.6 kW (SOLIVIA 7.6 TL) and 30 solar modules (Q.PEAK-G3 265-280).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16010	19041-20000-09848	16903 W KESWICK ST pv1	91406	6	186B133    77	2203012002	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	PIN	34.20987806	-118.50157905	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16011	13041-20001-34745	22450 W HATTERAS ST	91367	3	174B101    86	2040039007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2013 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.17595	-118.61633	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. POWER OPTIMIZERS USED. TOTAL SYSTEM SIZE 6.0KWAC. 24 modules and 1 inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16012	17041-20000-02495	3423 W FERNCROFT ROAD	90039	13	153A207   228	5437020018	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Expired	09/13/2023 12:00:00 AM	ADDRESS	34.11281	-118.26274	Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 225A MSP.7.04kW ungrounded system. (22) 320W AC modules. Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16013	15041-20000-02659	12500 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16014	13041-10000-26418	4664 N DEL MORENO DR	91364	3	168B113   418	2174019014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM			Reviewed by Supervisor	10/10/2013 12:00:00 AM	ADDRESS	34.15491	-118.57526	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH 400A LOAD BUS, (2) 200A PANELS AND EXISTING SOLAR INSTALLATION. ANTICIPATED INSTALLED SYSTEM SIZE IS 5.635 KW DC ( 23 X 245W) ON non-standard plan IN A 1-story  HOME. NEW load center IS UTILIZED.(23) MODULES: TRINASOLAR TSM-245PA05.18(1) INVERTER: POWER-ONE #AURORA PVI-50000OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16015	09041-30001-14323	6030 W WILSHIRE BLVD	90036	4	135B177   533	5086010001	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM			PC Approved	03/04/2010 12:00:00 AM	ADDRESS	34.06266	-118.36039	Plan check only.  Delta 3 revision to lighting plans and T-24 calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16016	12041-10000-09759	14006 W RIVERSIDE DR #80	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	08/07/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I. OF EXISITING RETAIL SPACE # 80 PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16017	19041-10000-28990	523 W 6TH ST 9TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.04864	-118.25484	ENERGY PC ONLY FOR NEW UNISEX RESTROOM IN THE 9TH FLOOR,  AREA 445SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16018	15041-10000-25657	1149 S HILL ST 3RD FL.	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.03926	-118.26099	PC for T-24 only, total area : 1,312 sq. ft. Office Space. Scope of work is on the 3rd fl.Office is in a high rise bld. (11 fl).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16019	15041-20000-09722	1418 N NORTH SPRING ST	90012	1	136-5A217  75	5409004002	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.06685	-118.23206	Plan check for power and energy. Total outdoor lighting area = 16,225 sq. ft. Service upgrade to existing commercial building. Interior tenant improvement shall be done under a separate permit. Completely new electrical distribution system with 1600 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16020	09041-10002-24166	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM	06/25/2010 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	Changes from prevously approved plans.  Changes include new conveyor system which consists of new switchboards and motors.  Plan check for power only.  Approved plans submitted for reference only.*****T.I. /   baggage screening area addition to existing terminal 5 at L.A.X.****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16021	15041-10000-21786	6201 W HOLLYWOOD BLVD STE 118	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM			Reviewed by Supervisor	08/14/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR RETAIL CENTER. TOTAL RAEA 1516 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16022	10041-20000-17181	6227 W WILSHIRE BLVD	90048	5	135B177   485	5510027037	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	ADDRESS	34.06349	-118.36419	PLAN CHECK POWER AND ENERGY FOR DENTAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16023	10041-10000-23110	6862 N HAYVENHURST AVE	91406	6	183B137   380	2224019016	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.19561	-118.49221	TI IN AN EXISTING WAREHOUSE AREA.  PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16024	10041-20000-11745	8214-8216 N VAN NUYS BLVD	91402	6	192B149   493	2212004033	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM			PC Info Complete	07/08/2010 12:00:00 AM	ADDRESS	34.22025	-118.44858	PLAN CHECK POWER AND ENERGY TENANT IMPROVEMENT FOR A CHANGE OF USE FROM RETAIL TO DENTAL CLINIC. EXISTING PANEL. KIDS DENTAL KARE. PLAN CHECK ONLY. PERMIT UNDER #10041-10000-14354	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16025	14041-20000-08224	9241 N RESEDA BLVD	91324	12	198B125   220	2763009038	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.23836	-118.53628	PC FOR POWER ONLY. NEW 800A SERVICE. SERVICE CONSOLIDATION FOR 2 FUTURE TENANTS AND 2 EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16026	13041-20000-22749	6411 N SEPULVEDA BLVD 2B-2C	91406	6	180B145   763	2234016013	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	PIN	34.18706228	-118.46668363	Change of use to Medical.  Full Plan Check for power and Energy.  Building is State Licensed, MUST BE Checked for OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16027	12041-20000-17960	911 E PALMS BLVD	90291	11	108B145    65	4241009018	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	09/14/2012 12:00:00 AM	ADDRESS	33.99583	-118.46001	Photovoltaic system on roof of single family dwelling using Enphase M215 inverters, with installation of circuit for Enphase Enlighten System.  Use existing service equipment, and existing conduit stubouts for the photovoltaic system, located at roof, and at the ac disconnect location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16028	15041-10000-30620	541 S SPRING ST 134-137	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.04657	-118.2507	Full plan check. Tenant imrovement to a commercial bldg. Change of use from retail to restaurant. (14) story high rise building. Scope of work is being done on ground floor. Pc for power and energy. Sq ft = 4861	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16029	17041-10000-06151	14006 W RIVERSIDE DR 112/122	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Issued	02/27/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24, PC FOR ENERGY ONLY. TI TO FOR AN EXISTING COMMERICAL BUILDING FOR SUITES # 112  & SUITE # 122. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1235 SQ. FT. B#16016-20000-27124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16030	14041-20001-24806	7000 S HOOVER ST Unit #8	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	expedite feesNew roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #8.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16031	14041-10000-29668	1002 N WILCOX AVE	90038	13	144B185   949	5533014011	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.08908	-118.33084	Electrical,  change of use,  from a duplex to child care facility, full plan check, building submitted in 2013. old title 24. plan check for power lighting , title 24 and emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16032	13041-10001-24720	17224 W BULLOCK ST	91316	5	177B133    49	2255007018	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.17969	-118.50854	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16033	16041-10001-38684	9165 N GLENOAKS BLVD	91352	6	198B173   145	2408033038	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.23566	-118.37289	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV INSTALLATION OF NEW 49.050 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING. (150) MODULES: SUNPOWER SPR-X20-327-COM(2) INVERTERS: SMA AMERICA STP 30000TL-US-10>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16034	19041-10000-43321	4750 W WILSHIRE BLVD 1-3 FLR	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			PC Info Complete	11/06/2019 12:00:00 AM	ADDRESS	34.06185	-118.3338	Energy plan check for a T.I. Scope includes new lighting and equipment with a total lighting area of 3,890 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16035	15041-20000-38781	24625 W STAGG ST	91304	12	189B089   312	2017027038	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.2122	-118.65701	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE : 17.658 KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16036	12041-10000-06315	1532 W PALOS VERDES DR NORTH BLDG L	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	9800.15	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM			PC Approved	07/24/2012 12:00:00 AM	ADDRESS	33.77932	-118.30458	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building L. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16037	14041-20000-33213	938 S ORANGE GROVE AVE	90036	4	132B177   563	5086012008	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.05864	-118.36241	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16038	15041-30001-42254	5128 N BLUEBELL AVE	91607	2	171B161   692	2357002010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	12/31/2015 12:00:00 AM	ADDRESS	34.16372	-118.41036	Expedite fees only.     Addition of new roof mounted solar PV array to existing roof mounted solar PV system on existing single family dwelling.  Total system size = 13.2 kWac (6 kWac new).  Addition of one inverter to existing two inverter system (three inverters total).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16039	17041-20000-31449	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.2215	-118.42999	T.I. of (E) medical office.  Patient care areas and office space.  Plan check for power and energy.building permit # 17016-20000-24383	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16040	14041-20000-30126	900 N CAHUENGA BLVD	90038	13	144B185  1190	5533019012	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.0873	-118.32862	Plan check for energy only. New outdoor lighting around an office building. 35,840sqft. Building permit prior to July 1st, 2014 -- using 2008 Energy Code.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16041	13041-20001-00418	10506 W SANTA MONICA BLVD 1-3	90025	5	132B157   982	4317003002	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.0551	-118.4269	New 3rd Floor Addition to an existing mixed use (commercial/residential) building.  Full Plan Check.  Site is a Methane Zone.  ALL conductors or conduit are to be run above grade, per Engineer. (((SUPPLEMENTAL APPLICATION FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 2. CHANGE IN T24 AND LOADS REFLECTED. ))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16042	15041-10000-12042	921 S CROCKER ST	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	FIRST TENANT IN RETAIL SPACEFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16043	18041-10000-13946	18711 W VENTURA BLVD	91356	3	174B121   513	2160002050	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.1711	-118.54127	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16044	19041-20000-18308	7140 S LA TIJERA BLVD	90045	11	102B173   437	4103009098	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Issued	05/28/2019 12:00:00 AM	ADDRESS	33.97299	-118.37628	PV2.  Install 22.44 kW DC / 20.9 kW AC CEC roof mounted grid tied PV system.  (68) modules with (2) 9 kW three phase inverters interconnected with 1200A 208Y/120V service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16045	16041-20001-41331	5998 W PICO BLVD	90035	10	129B173   351	5068012001	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM			PC Approved	01/23/2017 12:00:00 AM	ADDRESS	34.05216	-118.371	01/23/2017 Changes to an approved set of plans. Changes have been made to the single-line diagram to reflect existing service and service equipment.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT. CHANGE OF USE TO RESTAURANT. 1387 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16046	14041-20000-34950	10454 N GLORY AVE	91042	7	204B201    96	2569024032	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.2591	-118.28074	PERMIT FEE IS $0.00 BY STATE SENATE BILL NO. 1222PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main breaker to 150A.System size: 11.18kW. Ungrounded system.52 EnPhase M215 microinverters with 52  275W pv modules across 5 strings (5+13+14+8+12). Combining string of 5 with string of 8.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16047	16041-30000-32873	2044 S SAWTELLE BLVD	90025	11	126B153   794	4261032025	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Issued	09/22/2016 12:00:00 AM	ADDRESS	34.04006	-118.44266	Plan check Title 24 only in existing space single building T.I. Total indoor area: 3,680 sq ft. Total outdoor area: 2,040 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16048	16041-10002-40602	11120 W CHANDLER BLVD Build. 2	91601	2	171B173   257	2350015036	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			PC Approved	05/31/2018 12:00:00 AM	ADDRESS	34.168	-118.37317	THIS SUPP. IS TO COLLECT ADDITIONAL HOURS FOR THE SCOPE ON SUPP. 10001NO PERMIT ON THESE CHNAGES. TOTAL REMOVE LARGER THAN TOTAL ADDED.Supplemental PC for changes to approved set.Changes include new lights, receptacales, panels, equipment  removal of fire pump, addition of electrical room and addition of transformer disconnects. All changes clouded under delta 1,2,3,4,5 AND 8.This is plan check only!	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16049	16041-10000-40954	3273 W CASITAS AVE	90039	13	153B209   393	5436002023	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.11638	-118.25202	TI TO AN (E) SPACE, SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 715.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16050	13041-10000-09148	20455 W SORRENTO LANE Bldg A	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM				INSTALLATION OF NEW FIRE ALARM SYSTEM. TOTAL DEVICES 145. 3-STORIES HIGH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16051	10041-20000-20810	3481 E 14TH ST	90023	14	118-5A225 357	5190036025	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	03/25/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.01738	-118.20365	Plan check 109.89KW photovoltaic sytem with 2 services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16052	19041-10000-22435	8701 S ST ANDREWS PL	90047	8	096A193     3	6036009900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	33.95975	-118.31141	New Fire Alarm System, 1 FACP and 73 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16053	15041-10000-18508	4813 W OAKWOOD AVE 1-18	90004	4	138B193   209	5522030010	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.07741	-118.31188	NEW CONSTRUCTION OF 4-STORY DEVELOPMENT AS FOLLOWING.  4-STORY, 18-UNIT MULTI-FAMILY RESIDENTIAL BUILDING OVER 1-STORY SUBTERRANEAN PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16054	19041-20000-45904	18213 W LAKE ENCINO DR	91316	5	165B125   233	2184031022	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.14832	-118.53104	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 11.34 KW DC/10.26 KW AC CEC. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS AND A 10 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16055	16041-20000-30479	1901 E 15TH ST	90021	14	120A215    62	5167017019	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.02299	-118.23658	ADDITION OF NEW 800KW GENERATOR AND TRANSFER SWITCH TO EXISITNG DISTRIBUTION BOARD.  GENERATOR IS OPTIONAL.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16056	15041-10000-23061	5739 E YORK BLVD	90042	14	154-5A229  84	5484010019	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM			PC Approved	07/20/2015 12:00:00 AM	ADDRESS	34.11881	-118.19231	TI TO AN EXISTING SINGLE STORY COMMERCIAL SPACE.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 487.PERMIT FEES PAID UNDER 14041-10000-33587.  THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16057	17041-10000-35609	808 N LILLIAN WAY	90038	13	141B185   248	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.08566	-118.32757		N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16058	19041-10000-45410	11552 W KILLION ST	91601	2	174B169  1017	2350002015	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.17117	-118.38398	NEW ROOF-MOUNT PV1 INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 21 MODULES (MSE310MCIJ), 21 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE5000H-US).SYSTEM SIZE: 6.51 KW DC; 5 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16059	15041-20000-17672	6929 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.19659	-118.49256	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 10,751 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16060	17041-20001-43173	2230 S BEVERLY GLEN BLVD	90064	5	129B157   650	4315009022	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.04961	-118.41969	expeditepv2install roof mounted pv system sized 20kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16061	10041-10000-20506	8941-8955 N TAMPA AVE 101-103	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Public Safety Only			10/14/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Expired	09/19/2014 12:00:00 AM	ADDRESS	34.23285	-118.55413	NEW FIRE WARNING SYSTEM AND CENTRAL STATION MONITORING FOR A COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16062	17041-20000-20466	5711 N SEPULVEDA BLVD	91411	4	174B145   884	2260010017	CM-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.17435	-118.4665	Plan check for energy only. TI to existing target - new lighting in grocery area and home dept. Relocating lighting in checklane area. 20,145sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16063	18041-10002-25300	8502 W SHERWOOD DR	90069	5	141B173   300	4337003063	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.08477	-118.37667	"DELTA 7 CHANGES TO APPROVED PLANS FOR ADDING ""G1"" & ""G2"" FIXTURES. T-24 ENERGY ONLY (1264 OUTDOOR & 3616 INDOORS)__________________PC FOR TENANT IMPROVEMENT FOR RETAIL STORE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA 4959 SQ.FT (INDOOR AND OUTDOOR).B# 18016-10000-21609"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16064	13041-10000-06377	2614 N ZORADA DR	90046	4	153B177    74	5569020044	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.11865	-118.36215	photovoltaic system for single family dwlling. system size 15kw. total of 60 panels. nonstaqndard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16065	19041-10000-11591	1019 E 4TH PL floor 2	90013	14	127-5A217  60	5163018006	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.04195	-118.23327	FULL PLAN CHECK FOR FIRST TIME TENANT FOR - FULL FLOOR 7,773 SQFT. (LEVEL 2)OFFICE USE. THE SCOPE OF WORK INCLUDES INTERIOR NON-LOAD BEARING PARITTIONS, AND FINISHES - CONNECTED TO EXISTING SERVICE - NEW COONECTED LOAD IS APPROX. 200A OF CONNECTED LOAD USING TRANSFORMER(75KVA), TOTAL AFFECTED AREA = 10600 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16066	19041-10000-45677	4571 W DON RODOLFO PL	90008	8	114B177   129	5028007024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.01076	-118.354	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 12  (HANWHA Q-PEAK DUO BLK-G5/SC315) MODULES, 12  (SOLAREDGE P-400) OPTIMIZERS, 1 (SOLAREDGE SE 3800H) INVERTER, 1 TELSA POWERWALL CONNECTED TO AN EXISITING 200A PANEL. SYSTEM SIZE IS 3.780KW DC, 3.80KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16067	17041-20000-24495	800 W OLYMPIC BLVD 5TH FLOOR	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.04484	-118.26453	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HERBALIFE OFFICE. 5TH FLOOR. HIGH RISE. 3275 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16068	19041-10000-06471	400 S GAFFEY ST #7	90731	15	015B197    38	7451026001	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	33.74042	-118.29213	Energy plan check for retail T.I. Scope includes new lighting and equipment with a total area of 2,412-SQ FT. Portion of permit fee is paid under 19041-40000-01487.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16069	13041-10000-20700	7124 N DE CELIS PL	91406	6	183B137    92	2225004039	(Q)MR1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Info Complete	08/02/2013 12:00:00 AM	ADDRESS	34.20004	-118.49443	TITLE 24 PLAN CHECK ONLY. WAREHOUSE. TI FOR TWO ROOMS ONLY AND CORRIDOR. SQFT 1524. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 1 STORY. EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16070	15041-10000-07273	14924 W HUBBARD ST	91342	7	216B149   619	2612023014	RS-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.28512	-118.45638	PV1 INSTALL 5.232 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(16)MODULES, (1)INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16071	17041-10002-19822	17541 W LANARK ST	91325	12	189B129    82	2201006009	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.21808	-118.51567	Supplemental PC for changes to approved set. Changing location of powerwall and disconnect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16072	19041-20000-32053	20805 W ACORN CIR UNIT #165	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.29451	-118.58676	PV1.  Install 3.15 kW roof mounted PV system.  (9) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16073	14041-20000-13275	20510 W BRYANT ST	91306	3	195B109   418	2780016015	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.22718	-118.58026	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 864 WATTS. USING ENPHASE MICROINVERTER M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16074	14041-10000-20580	525 S HEWITT ST	90013	14	126A215    76	5163023900	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.04076	-118.2351	PV2, INSTALL 178.5  KW DC, NON ROOF-MOUNTED SOLAR ARRAY ON A OFFICE BUILDING carport (DWP), INTERCONNECT WITH EXISTING UTILTY SERVICE.(714) MODULES(2) INVERTERS: (1) 100KW & (1)75 KW [negatively grounded]51 STRINGS.LADWP  BUILDING, LA CITY PROPERTY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16075	17041-20000-14452	239 W 25TH ST	90007	9	121-5A205 138	5126020012	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.02729	-118.27101	$0 permit fee per State Senate Bill SB1222. Plan check for roof-mounted solar pv system on commercial building. Interconnect with a 400A MSP.30kW ungrounded system. (108) 275W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16076	14041-20001-10776	20849 W EXHIBIT PL	91367	3	177B109    26	2149012017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.17892	-118.58682	Fee for expedite only.*****Roof mounted PV system, system size 6.75KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16077	19041-20001-01450	665 E BROOKS AVE	90291	11	111B145  1720	4239008***	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM			PC Approved	08/21/2019 12:00:00 AM	ADDRESS	33.99668	-118.46674	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. MINOR CHANGE TO SINGLE LINE. UPSIZING OF CONDUCTORS AND THE DOWNSIZED MAIN CIRCUIT BREAKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16078	19041-10000-30758	811 E G ST	90744	15	030B209   249	7424011058	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	06/18/2020 12:00:00 AM	ADDRESS	33.77919	-118.25275	Plan Check for energy only. Tenant improvement of (E) warehouse to manufacturing (R&D). Scope of work includes new lighting and circuits to existing panels. Total sq. ft. 1024.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16079	19041-20000-49662	1377 N SERRANO AVE 1ST FLR	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.0965	-118.30717	Plan check for Title 24 Energy only. new lighting in the space, newly connected load is less than 400A. Total area: 10,499 sq ft. B#19016-10000-38348	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16080	17041-20001-31314	4947 N CHIMINEAS AVE	91356	3	168B125   112	2181019008	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2017 12:00:00 AM			PC Approved	09/28/2017 12:00:00 AM	ADDRESS	34.15993	-118.52912	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (20) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16081	13041-10000-06903	1535 S PALOMA ST	90021	9	121-5A211 132	5132025004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	34.02782	-118.25063	RENOVATION OS EXISTING SERVICE LINE. DAMAGED CONNECTIONS REQUIRING PERMIT FOR RECONNECTION. 800A SERVICE LINE. PC FOR POWER ONLY. MOST EQUIPMENT EXISTING BUT NEW WIRING IN THE SAME LOCATION. (EQUIPMENT REPLACEMENT LIKE TO LIKE.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16082	17041-10003-02377	433 S SPRING ST	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	ADDRESS	34.04822	-118.24907	Supplemental Plan check for changes noted as Delta - 28. Scope of work includes the relocation of the Fire pump feeder from the emergency board to the generator. <<<<PC FOR POWER AND ENERGY. EXTENDING  OFFICE  ON THE LEVEL 2 MEZZANINE, AND T.I FOR  OFFICE AND RETAIL IN A 13 STORY BUILDING.  SHELL ONLY.  NEW SERVICE 5000A 480/277 V. TOTAL AREA  38408 SQ FT.B# 16014-10000-04123>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16083	12041-10000-17957	7525 N LOCKHEED DR	91505	2	186B177   566	2466036006	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.20717	-118.35391	Plan check for energy and emergency lighting. 1720 sqft. Standalone building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16084	19041-10000-44897	3734 S CRENSHAW BLVD	90016	10	117B185   240	5033001039	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.0188	-118.33468	Plan check for power and Energy for existings space. Scope includes new lights, receptacles, and X-rays.  Total lighting area of 1730-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16085	11041-10000-12541	1225 S GRAND AVE	90015	14	126A207   129	5139022010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/21/2011 12:00:00 AM	ADDRESS	34.03967	-118.26397	TI TO AN EXISTING RETAIL SPACE WITH OFFICES BUILDING.  PLAN CHECK IS FOR ENERGY AND EMERGENCY ONLY.  OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16086	17041-20000-22670	15900 W VALLEYVIEW CT 2nd Floor	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for energy only. TI to training room/offices on second floor of existing commercial building. New lighting (incl. emergency). 8,699sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16087	13041-20001-27923	3725 N ROSEMEAD AVE	90032	14	144A233   286	5306015055	RD3-1	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.08796	-118.17656	(((EXPEDITE FEES))))PV2 MULTI FAMILY DWELLING. PC FOR 6KW AC USING 22 MODULES WITH CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16088	12041-10000-11756	7511 S DUNBARTON AVE	90045	11	102B161   210	4110026009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	33.97242	-118.41036	New 6kw, rooftop, photovoltaic system for an existing sfr.  System uses Solar Edge DC-DC converters.  Permit for Misc is for Solar Edge converters.  System is in a methane zone and will comply with requirements for Methane Level V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16089	12041-10000-03175	10200 N LAUREL CANYON BLVD	91331	7	204B157   639	2646011012	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	05/01/2012 12:00:00 AM	ADDRESS	34.25603	-118.429	Plan check for new roof mounted 1.38KW Enphase M215 Microinverter photvoltaic system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16090	15041-20001-20377	13724 SHERMAN WAY	91405	2	183B157   987	2216027023	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	PIN	34.20070651	-118.43211614	[[[12/22/15 T24 PLANCHECK ONLY. SUPPLEMENTAL PLANCHECK TO UPDATE T24 AND FIXTURES TO MATCH INSTALLATION]]]]Plan check Title 24 only for existing restaurant T.I. Total indoor lighting area: 2,260 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16091	19041-10000-14309	1221 E WHOLESALE ST	90021	14	124-5A215  10	5164010005	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.03666	-118.23769	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16092	15041-10000-22320	11405 W CHANDLER BLVD	91601	2	171B173   101	2350011016	C4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			07/14/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.1682	-118.37935	NEW 7-STORY MIXED-USE BUILDING (5-STORY TYPE V APARTMENT OVER 2-STORY TYPE I PARKING GARAGE AND RETAIL ON GROUND FLOOR). APARTMENT WITH 82 RESIDENTIAL UNITS.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16093	16041-20000-16863	19930 W ECCLES ST	91306	3	192B113   366	2782039015	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.22288	-118.56778	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (26) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16094	18041-20000-41973	5750 W LEXINGTON AVE	90038	13	144B189   358	5536006024	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			11/01/2018 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	01/27/2021 12:00:00 AM	ADDRESS	34.09266	-118.31534	Plan check for new multi-family 4 story building 9 units 600A Service. Total area: 10532 sq ft. B# 18010-20000-02150	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16095	17041-10003-24720	1350 N IVAR AVE	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM				"DELTA B REVIONS OF DRAWINGS SHOWING WIRING OF THE LUMINAIRES IN STAIRWELL TO MEET REQUIREMENT THAT ""LIGHTING BE ON ALL THE TIME""((((((((PC FOR SHELL  AND CORE FOR MIXED-USE COMMERCIAL DEVELOPMENT WITH 3 LEVELS BELOW GRADE PARKING FOR POWER AND ENERGY."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16096	19041-20000-41197	20823 W PINECONE CIR UNIT #19	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.29588	-118.58771	PV roof mounted system, PV system size: 4.2KW with 12 PV Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16097	12041-10000-24721	5900 W WILSHIRE BLVD # 700	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.06237	-118.35809	RENOVATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16098	19041-20000-04657	7032 S RAMSGATE PL	90045	11	102B173   397	4103011016	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	33.97338	-118.37312	pc change include adding 1 inverter, emergency ltgs and update T-24 forms. change marked delta 1. original electrical permit #: 16041-20000-32337	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16099	18041-10000-24570	5744 W MANCHESTER AVE	90045	11	096B169   555	4125016019	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Issued	07/17/2018 12:00:00 AM	ADDRESS	33.95971	-118.38187	PC FOR FACADE REMODELING FOR (E) MARKET FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS IN THE FACADE. TOTAL AFFECTED AREA 158 SQ. FT B# 16016-10000-03500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16100	10041-10000-07767	262 S LAKE ST	90057	13	135A205   113	5154018021	R4-1	Central	Westlake		YES	2085.00	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	12/27/2010 12:00:00 AM	ADDRESS	34.06466	-118.27277	INSTALL A NEW FIRE LIFE SAFETY SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16101	18041-10000-38700	11408 W SARAH ST	91602	2	168B173   980	2365013023	RD1.5-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Apartment			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	PIN	34.15357905	-118.3793427	New Fire Alarm system for a New 3-story, 10-unit apartment building	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16102	07041-10006-26513	940 E 2ND ST	90012	14	129A217   202	5163006017	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			06/20/2011 12:00:00 AM			PC Approved	06/20/2011 12:00:00 AM	ADDRESS	34.04698	-118.23369	REVISED PLANS TO ADDRESS INSPECTION CORRECTION NOTICE U 29078UNIT C AND E DOWN SIZE ELECTRIC OVEN RATING AND UPSIZE THE CU UNITS AND INSTALLED LOW VOLTAGE LUMINAIRE IN  ROOM ON THE THIRD LEVEL (((((((REMODEL EXISTING 10 JOINT LIVING AND WORKING QUARTER RENTAL UNITS FOR ARTISTS AND ARTISANS AND CONVERSION OF REMAINING EXISTING M3-1 ZONED INDUSTRIAL WAREHOUSE BUILDING INTO 30 UNIT JOINT LIVING AND WORKING QUARTER CONDOS FOR ARTISTS/ ARTISANS & PARKING GARAGE. A TOTAL OF 40 UNITS FOR THE PROJECT. WITH ON SITE PARKING.  METHANE ZONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16103	14041-10001-10510	1630 W 1ST ST	90732	15	018B193   703	7559014029	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	33.74414	-118.31293	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(27) TRANSFORMERLESS INVERTER: SOLAREDGE # SE6000A-US-ZB-U(1) MODULES: CANADIAN SOLAR # SC6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16104	15041-20000-12786	6200 W HOLLYWOOD BLVD	90028	13	148-5A189 130	5546028002	[T][Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			04/28/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.10136	-118.32459	Plan check for power and energy New 7-Story mixed use Bldg  527 units. Added more circuits to match pre-cut Check. Added circuits shall account for the permitm fees. fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16105	16041-10000-10518	8259 N SUNLAND BLVD	91352	6	192B173   561	2632025030	[Q]C2-1VL-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.22091	-118.36777	PC FOR ENERGY. T.I FOR FIRE DAMAGE REPAIR FOR EXISTING BAKERY. AREA 2210 SQ FT(INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16106	15041-30000-43265	445 S FIGUEROA ST 33 FLOOR	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.05295	-118.25675	Title 24 plan check only.  Total area = 845 sq. ft.    T.I. to lobby and restroom areas on 33rd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16107	15041-10000-07097	620 W 43RD PL	90037	9	114A201   400	5019010030	RD2-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Expired	04/04/2017 12:00:00 AM	ADDRESS	34.00447	-118.28486	PV1 5kw roof-mounted system including (1) ABB-PV1-5000-OUTD inverter and (23) Yingli YL255p modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16108	15041-10000-35888	6430 W SUNSET BLVD STE-600	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.09782	-118.32979	Energy plan check for an office T.I located in the 6th floor of a high rise building.  Scope includes new lighting, receptacles and equipment; Total area is 12,528-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16109	19041-10001-20423	580 N PASEO MIRAMAR	90272	11	129B117    65	4416019059	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM			PC Approved	06/27/2019 12:00:00 AM	ADDRESS	34.04695	-118.55707	**Expedite Fees****Full PC for PV1 for a roof mounted system system size is 13.33 KWdc/11.4 KWac.  Scope of work is 43 modules with optimizers ( P320) , 2 inverters (SE3800 H-US, and SE7600A-US), 2 batteries (LG RESU10H 9.8 KW) , One new load center rated at 100 A, and a new subpanel rated at 125 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16110	15041-10000-05342	14944 W MAGNOLIA BLVD	91403	4	171A147     9	2263005076	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.16465	-118.45906	New fire alarm system for a 3-story, 18-units apartment; project including (1) fire alarm panel, (1) annunciator, (1) power supply and ( 66) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16111	10041-10000-21411	20970 W WARNER CENTER LANE	91367	3	174B109   231	2149017010	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	12/28/2010 12:00:00 AM	ADDRESS	34.17478	-118.59087	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16112	16041-20000-43903	12251 W CASTLEGATE DR	90049	11	138B141   349	4494002006	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.07323	-118.48051	New 2-story single family residence with subterranean basement with 800A 3ph-4w service and 20 kW standby generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16113	19041-10000-24676	4360 S FIGUEROA ST	90037	9	112-5A201  19	5019029027	C2-2D-CPIO	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.00422	-118.28247	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16114	17041-20000-45228	26640 S WESTERN AVE	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	33.78015	-118.30862	Plan check for fire alarm system. New fire alarm system for commercial building. 1 FACP. 47 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16115	18041-20000-09138	1354 W 190TH ST	90501	15	060B193   453	7351002032	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	33.85803	-118.30147	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 2715.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16116	16041-10002-15949	2529 N WORKMAN ST	90031	1	139-5A221 200	5204013008	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.07619	-118.21454	PC FOR PERMIT ALREADY ISSUED. 3 UNIT APARTMENT PV INTERCONNECT TO 1 OF THE SERVICE METERS. SYSTEM USES 14 MODULES WITH ENPHASE MICROINVERTER M250	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16117	16041-10000-41457	333 S HOPE ST STE-2500	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	Energy plan check for an existing office located in suit-2500 of a highrise building. Scope include new lighting, receptacles, and other equipments. Total area is 7681 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16118	11041-20000-14895	1880 S CENTURY PARK EAST 104	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM			PC Approved	08/08/2011 12:00:00 AM	ADDRESS	34.06144	-118.41437	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR CHANGE OF USE FROM OFFICE TO BANK.  SUITE #104. OUTDOOR ATM LIGHTING EXEMPT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16119	12041-10001-07426	1801 E 50TH ST 1st floor	90058	9	111A213   156	5106027004	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM			PC Approved	04/16/2012 12:00:00 AM	ADDRESS	33.99812	-118.24177	PLAN CHECK FOR REVISION TO T24 ENERGY PLAN. CHANGES TO THE AREA CONTROL AND ADDITIONAL AUTO SHUT OFF OVERRIDE SWITCHES INSTALLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16120	14041-20000-19626	6110 N VARIEL AVE	91367	3	177B105    51	2149005034	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.18136	-118.59257	Plan check for energy only. Relocate lighting in 1st floor offices in existing 2-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16121	19041-20000-53264	6001 N VAN NUYS BLVD	91401	6	177A151    92	2241027004	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	04/14/2021 12:00:00 AM		Permit Finaled	01/18/2024 12:00:00 AM	ADDRESS	34.17961	-118.44899	New auto dealership with offices, showroom, service, and parking.  2500A 480Y/277V service.  Plan check for power and energy.  Building permit filed under 17010-20000-03375.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16122	11041-20000-14794	127 S SAN VICENTE BLVD Bulletin-68TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	07/28/2011 12:00:00 AM		Permit Closed	02/15/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin-68TI REVISION. New branch ckts added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16123	16041-20000-03920	14111 W BERESFORD ROAD	90210	1	129B197  1299	5075005021	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.13316	-118.43859	Plan check for Single Family dwelling 2 story for 600A 120/240V service with backup generator. Total area: 12,000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16124	10041-20000-07674	404 W 7TH ST	90014	9	129A209   224	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Public Safety Only			04/27/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.04601	-118.25486	Replacing a FACP for high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16125	15041-10000-16736	5107 E ALHAMBRA AVE PV1	90032	14	138A233   236	5216025002	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2016.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	34.07173	-118.17485	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) KYOCERA 260 MODULES(1) ABB PVI 3.0 INVERTERPERMIT FEES PAID UNDER APPLICATION NUMBER 15041-10000-15269Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.  2.08 KW PV SYSTEM (8) MODULES The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16126	15041-10000-20996	11700 W SANTA MONICA BLVD	90025	11	126B149   327	4262007006	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Closed	08/05/2015 12:00:00 AM	ADDRESS	34.04351	-118.45614	PC FOR T24. T.I FOR OFFICE, NO CHANGE OF USE. TOTAL AREA 2230 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16127	12041-20000-13663	7035 N ETON AVE	91303	3	183B105   550	2138015008	[T][Q]MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.19848	-118.59559	Electrical system for new masonary building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16128	10041-10000-20641	10656 W VICTORY BLVD 1-49	91606	2	180B177   275	2414018001	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03, 1231.04	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	10/18/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.18636	-118.36343	Install a new Fire Alarm System in the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16129	12041-10000-07210	438 S ORANGE DR	90036	4	135B181   490	5507011019	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.0658	-118.34171	New 4.3kw rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16130	19041-20002-09551	7304 N JORDAN AVE	91303	3	186B105   848	2111013022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	34.20311	-118.60273	$0 PLAN CHECK FEE DUE TO SB1222SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CHANGE TO SINGLE LINE, CHANGE SUB PANEL SIZE FROM 600A TO 225A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16131	15041-10000-20838	5727 N FULCHER AVE	91606	2	174B173   524	2337030008	R1-1	South Valley	NORTH HOLLYWOOD - VALLEY VILLAGE	MID-TOWN NORTH HOLLYWOOD		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	PIN	34.17468939	-118.37333611	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(15) SUNPOWER MODULES(1) POWER-ONE INVERTER 4.2PLAN CHECK SUBMITTAL PER APPLICANT REQUEST.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16132	16041-10000-40193	11955 W HESBY ST	91607	2	171B165   910	2355002001	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.16227	-118.39409	PV1. NE SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.96KWac.(32)MODULES-LG ELECTRONICS LG320N1C-G4(32)MICROINVERTERS-ENPHASE S280-60LL-2-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16133	14041-10001-17164	15300 W VALLEY VISTA BLVD	91403	4	166-5A145 216	2281005006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	ADDRESS	34.14874	-118.46757	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS.(42) MODULES: CANADIAN SOLAR CS6P-250PX(2) TRANSFORMERLESS INVERTERS: SOLAREDGE SE 5000A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16134	14041-10001-28972	200 WORLD WAY SPACE 231	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM			PC Approved	01/06/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Modifications to approved set.  Revised load.  New equipment to support water filtration system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16135	17041-10000-38499	777 S ALAMEDA ST 2nd Floor	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.03396	-118.24117	FULL PLAN CHECK FOR TENANT IMPROVEMENT (PHASE II) TO 2ND FLOOR OFFICE BUILDING. NEW CONNECTED LOAD > 200A WITH (4) NEW PANELS AND (1) 75 KVA TRANSFORMER.  NEW BUILDOUT OF SHELL SPACE FOR OFFICE SUITES, MEETING ROOMS, BREAK ROOMS.  B# 17016-10000-23627	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16136	12041-20000-13161	3700 S LA BREA AVE A	90016	10	117B177  1129	5046038801	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00, 2362.02	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.01929	-118.35537	T.I. to Dollar Tree store.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16137	19041-10000-43998	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	02/19/2020 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.23567	-118.5584	T-24 Energy Plan Check for Lighting on a 18172 sqft area. (Outdor Only) Scope of work includes new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16138	15041-20000-13211	4955 N VAN NUYS BLVD # 200,201,-204	91403	4	169-5A151  13	2263026046	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.16078	-118.4489	Plan check for power and energy. Project site is a medical office. Project scope is a tenant improvement which includes power and lighting within common areas and exam rooms. Panels are existing and to remain in place. Total lighting area = 3,057.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16139	19041-20000-28056	801 S GRAND AVE ste 275	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.04581	-118.25842	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16140	16041-10000-40731	16416 W KITTRIDGE ST	91406	6	180B137   336	2231004002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Issued	11/17/2016 12:00:00 AM	ADDRESS	34.19009	-118.49088	pv install 7.13 kw dc roof-mounted solar array on a single family house. (25) modules: solarworld sw 285(1)  inverter: solaredge se7600a-us(240)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16141	19041-20000-37417	3655 N VERDUGO VISTA TER	90065	14	154-5A219 131	5472010022	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.1187	-118.22354	Plan check for PV roof mounted system, PV system size: 5.2KW AC, 6.0KW DC with 15 PV Modules and 15 microinverters, and sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16142	18041-20000-42492	9900 N SEPULVEDA BLVD	91345	7	201B145   156	2660010166	[Q]C2-1VL, [T][Q]C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.25061	-118.46715	Plan check for Title 24 only outdoor lighting in existing space. Total area: 62,684 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16143	14041-20001-15521	11151 N LAUREL CANYON BLVD	91340	7	210B149   482	2613025054	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.27257	-118.44709	plan check for T24 energy only. addition of service area. new lights. Permit already pulled under original permit # 14041-90000-15521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16144	13041-10000-27347	12400 W WILSHIRE BLVD 6TH FLR	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	10/02/2013 12:00:00 AM	ADDRESS	34.04157	-118.47031	TITLE-24 PART 6, LIGHTING REMODEL FOR LOBBY AND CORRIDOR IN A HIGH-RISE BUILDING. SCOPE OF WORK WILL BE PERFORMED ON THE 6TH FLOOR. TOTAL AREA TO BE 860 SF. EXISTING EMERGENCY CKT FED VIA EXISTING GENERATOR PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16145	15041-20000-27761	15659 W LARKSPUR ST	91342	7	222B141    86	2604006015	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.30749	-118.47308	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (29) Kyocera KU265 Modules (1) ABB PVI-6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16146	19041-20000-38087	15301 W VENTURA BLVD Unit # P38-Unit #P39	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Issued	09/25/2019 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for Title 24 Energy for Tenant Improvement fo 2 retail sapce combine in to single space. Total area: 1667 sq ftB#19016-20000-18275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16147	10041-20000-21033	19503 S NORMANDIE AVE	90501	15	060B193   443	7351002030	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Finaled	07/21/2011 12:00:00 AM	ADDRESS	33.85617	-118.3012	Plan check for T24 Energy indoor, outdoor, and emergency lighting for general remodel of Walmart. New load does not exceed 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16148	17041-20000-19785	7040 N VAN NUYS BLVD	91405	6	183B149   254	2217007018	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Apartment			06/13/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.19874	-118.44853	Plan check for fire alarm system. New fire alarm system for 5-story assisted living (apartment) over 1-story of parking. 1 FACP. 920 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16149	15041-20000-02539	5717 N MAMMOTH AVE	91401	2	174B153   491	2246023008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.17438	-118.43248	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16150	12041-20000-01427	13645 W RIVERSIDE DR Ground Fl	91423	2	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	ADDRESS	34.15777	-118.43065	T24 and emergency lighting plan check for remodeled tenant area.  Partial ground floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16151	14041-20000-05382	23440 W COMMUNITY ST	91304	12	192B093   305	2005016025	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.22104	-118.63783	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING SOLAR EDGE SYSTEM WITH POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16152	14041-20000-35577	706-720 N CAHUENGA BLVD	90038	13	141B185   537	5533032014	C4-1XL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.08371	-118.32861	TI TO AN EXISTING COMMERCIAL 2 STORY BUILDING.  ADDING CIRCUITS TO EXISTINF PANELS, NEW LIGHTING AND CONTROLS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 27248.FEES ARE ESTIMATED PLAN CHECKER TO VERIFY.  CORE AND SHELL RENOVATION OF EXISTING STORE W/AXILLARY OFFICE, MANUFACTURING AND STORAGE TO OFFICE USE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16153	11041-20000-17231	16624 W VENTURA BLVD	91436	5	168B137   819	2284007016	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	34.1578	-118.49544	Core and shell retail space #11041-10000-05087.  New retail tenant #C (Vitamin Shoppe) to occupy space.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16154	14041-20000-16692	334 S MAIN ST C1002	90013	14	129A213   129	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			PC Info Complete	06/20/2014 12:00:00 AM	ADDRESS	34.04841	-118.24668	TI TO AN EXISTING COMMERCIAL ONE STORY BUILDING BUILDING, NEW LIGHTING ON EXISTING CIRCUITS.  SQUAREFOOTAGE 1639. PC FOR TITLE 24 ENERGY ONLY.Note: Permit is under 14041-20000-22219	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16155	18041-10000-08045	317 N EUBANK AVE #3	90744	15	030B209  1063	7424003036	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.77379	-118.25433	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 2450 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16156	11041-20000-19839	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM			PC Approved	09/19/2011 12:00:00 AM	ADDRESS	34.04835	-118.25882	T.I.   Work to be done is for Suite # 410.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16157	18041-10000-21263	13003 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	PLANCHECK FOR POWER AND ENERGY.  FIRST TIME TENANT FOR RESTAUARANT AFTER CORE AND SHELL.BUILDING PERMIT # 18016-10000-18203	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16158	14041-10000-30882	849 W 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	PIN	34.02383917	-118.28572873	New 2-story with mezzanine Dance Center building for assembly and classrooms.  PDPP  50% submittal for zoning, disabled access, green, partial fire life safety (no structural).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16159	12041-20000-25354	10866 W WILSHIRE BLVD 10th Floor	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.05907	-118.442	Express permit for two new branch circuits and 62 units.Plan check for energy and emergency lighting. High rise building. 10th floor. 1950 sqft, Office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16160	13041-10000-28864	3901 N EAGLE ROCK BLVD BLDGB	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.11925	-118.23127	"INSTALLING FIRE ALARM SYSTEM,   APARTMENT BUILDING ""B"" (2 OF 7 buildings)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16161	19041-10000-51870	5600 W CENTURY BLVD	90045	11	090B169    36	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	33.94469	-118.37969	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16162	14041-10001-07672	3401-3405 N GLENDALE BLVD	90039	13	156B209   343	5435006006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	07/08/2016 12:00:00 AM		Issued	07/08/2016 12:00:00 AM	ADDRESS	34.12023	-118.25882	PC FOR SERVICE CONSOLIDATION. EXISTING BUILDINGS TO REMAIN. NEW SERVICE AND REPLACE EXISTING PANELS PER NEW SERIES RATING. NEW 600A 240 3PHASE 4W((((((    Changes made to previously approveed set. sevice changed from 600 to 800 amps  M.Z 8-21-14.)))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16163	11041-20000-15312	333 S GRAND AVE level 30	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.05271	-118.25179	TI in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16164	17041-10000-11635	3405 S ARLINGTON AVE	90018	10	120B189   769	5042003048	C2-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	34.02518	-118.31781	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 10725 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16165	13041-10000-05760	1055 W 7TH ST SUITE-3100	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.0507	-118.26334	PLAN CHECK FOR TITLE 24 FOR TENANT IMPROVEMENT ON A HIGH RISE BUILDING. 7210 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16166	15041-20001-27673	5333 N OAK PARK AVE	91316	5	171B133    91	2258029014	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.16828	-118.50449	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (1) inverter and (38) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16167	16041-20001-23650	1327 S BRINKLEY AVE	90049	11	129B137   239	4407006015	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.05147	-118.49679	Expedite per applicant request(((((Plan check for PV roof mounted system. system size: 15.4kW with 45 modules and 2 inverters(7.7kW) connected to 400A service))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16168	11041-20000-22498	10540-10600 N WINNETKA AVE	91311	12	207B113   122	2708020009	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Issued	11/09/2011 12:00:00 AM	ADDRESS	34.26237	-118.57055	Plan check single family dwelling roof mounted 19.2KW photovoltaic system. Property has main house and detached guest house with seperate services. PV system on main house supplying each services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16169	17041-10000-13050	634 S CROCKER ST	90021	14	126A213   121	5147027040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.04081	-118.24494	PC for energy only, Indoor Title-24.  Removing HID fixtures and replacing with New LED. area: 1,800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16170	10041-20000-19833	8719 N BRADLEY AVE	91352	6	195B173   541	2408023017	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.22785	-118.37426	Plan check 36.19KW Photovoltaic System for commercial building. Permit for upgrading from 400A to 600A panel is included.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16171	14041-10000-19308	10261 N GLENOAKS BLVD	91331	7	204B165   134	2537017065	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.25646	-118.39487	$0 permit fee per senate bill 2222.  PV2. ROOFMOUNTED SOLAR SYSTEM. 106.3 KW DC. NEGATIVELEY GROUNDED SYSTEM(434) YINGLI SOLAR MODULES(3) COMBINER BOXES(1) SLECTRIA PV1 100KW INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16172	16041-10000-20473	1120 S GRAND AVE	90015	14	126A207    60	5139020094	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Closed	09/06/2018 12:00:00 AM	ADDRESS	34.04095	-118.26231	PC FOR TEMP POWER FOR CONSTRUCTION. 3 NEW SERVICES, TOWER CRANES, LIFTS AND POWER FOR FIRE PROTECTION. PC FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16173	13041-10000-27998	415 S BURLINGTON AVE 1-30	90057	1	133-5A205 194	5154023014	R4-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Apartment			10/08/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.06012	-118.26997	Installation of a new fire alarm system and to provide 24-hour system monitoring to sprinkler system.  99 devices, Advanced AX Series Intelligent Fire Alarm Control Panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16174	19041-10000-41153	12516 W VANOWEN ST	91605	2	180B165    29	2325001034	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	34.1938	-118.40609	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16175	19041-20000-40275	11612 W CULVER BLVD	90066	11	111B161   701	4217018032	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	06/29/2021 12:00:00 AM	ADDRESS	33.99891	-118.41424	Plan check for new Fire alarm system for 5 story 40 units multi-family building, new fire alarm device: 118 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16176	16041-10000-39098	9356 N LEMONA AVE class room-bldg	91343	7	198B149   174	2650034019	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.24086	-118.45871	PC FOR POWER AND ENERGY.  DEVELOPMENT OF A NEW PUBLIC CHARTER HIGH SCHOOL- CONSTRUCTION OF ONE NEW CLASSROOM BLDG. SERVICE  1200A . THIS APPLICATION IS TIED TO APP 16041-10000-39102 THAT IS FULL PLAN CHECK FOR ADDITION OF MULTI-PURPOSE AREA. FEES ARE COLLECTED FOR BOTH BUILDING APPLICATIONB# 16010-10000-04638	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16177	14041-10000-13363	12208 W MARSHALL ST	90230	11	108B161   770	4221019031	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	33.99	-118.41667	Install roof mounted pannels on residential home. 20 modules.System size = 5.1 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16178	19041-10000-31910												Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16179	11041-10002-23911	2020 S BUNDY DR	90025	11	123B149   367	4259020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Expired	08/14/2014 12:00:00 AM	ADDRESS	34.03347	-118.45477	Supplemental Plan Check  to change location of outlets, remove outlets, and add an additional outlet on a new circuit.              <<<<<tI WORK FOR AN EXISTING HARWARE STORE. ENERGY, OUT DOOR AND INDOOR, ADD GEN SET, POWER AND ENERGY. NOT A HIGH RISE. FIRE ALRM WILL BE DIFFERED.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16180	18041-10002-23117	450 S WESTERN AVE 204	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM			PC Approved	05/17/2019 12:00:00 AM	ADDRESS	34.06562	-118.30887	revision to an approved set t-24 only.BUILDING PERMIT #18016-10000-13573	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16181	15041-10000-11713	11120 W SHERMAN WAY	91605	2	183B173   117	2319002021	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	PIN	34.20070854	-118.37285504	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16182	18041-10000-16939	10212 W RIVERSIDE DR	91602	4	165B177   113	2424006039	[Q]C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.15204	-118.35324	DESIGN BUILD. ENERGY PLAN CHECK FOR A CHANGE OF USE FROM RETAIL TO BEAUTY SALON. SCOPE INCLUDES NEW LIGHTING AND RECEPTCLES. TOTAL AREA IS 896-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16183	13041-10001-06517	9149 N WHITE OAK AVE	91325	12	198B129   361	2766006019	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.23729	-118.52024	REVISION TO APPROVED PLANS. CHANGES TO INCLUDE SOLAR LOAD CENTER, ADDITIONAL 3.0KW INVERTER,  AND PV MODULES . NEW SYSTEM SIZE IS 9.25KW .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16184	13041-10002-30036	8014 W ELLENBOGEN ST	91040	7	210B193   368	2551037003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.27119	-118.30772	Expedited RSES plan check per applicant request.(((PV1.  Install 3.75 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3000A-US.  15 modules: Trina Solar TSM-250PA05.18)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16185	16041-10000-25639	1800 S AVENUE OF THE STARS ste #625	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	09/24/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	Plan Check for T-24 only, Tenant Improvement of existing office suite 625.  Install new lights, receptacles, and 100A panel, newly connected load < 400A. Total affected area: 2,875 sq.ftB# 16016-10000-13327	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16186	18041-10000-03192	5820 W LA MIRADA AVE	90038	13	144B189   223	5534019021	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			01/26/2018 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.09365	-118.31653	FULL PC FOR POWER AND ENERGY FOR A (N) 4-STORY (18) UNIT APT BLDG W/ BASEMENT SUBTERRANIAN PARKING GARAGE. SCOPE INCLUDES ADDING A NEW 1200A SERVICE. TOTAL AFFECTED AREA IS 18847 SQ. FT.((B# 16010-20000-04089))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16187	19041-20000-45680	16919 W SEPTO ST	91343	12	201B133   673	2685007020	R1-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.25125	-118.5008	PV1.  Install 6.82 kW DC / 6 kW AC roof mounted grid tied PV system.  (22) modules with 6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16188	17041-10000-41101	20904 W DEVONSHIRE ST	91311	12	204B109   177	2747001042	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.25708	-118.58896	REPLACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16189	16041-20001-45187	2300 E PACIFIC COAST HWY	90744	15	033B217     3	7428008905	M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	33.79043	-118.22853	4/18/2017changes to an approved set of plans.  classification non hazardous. plans verbage to reflect non hazardous.  (((Plan check for power only. Project site is an existing industrial location. Project scope is installation of equipment within a classified hazardous location.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16190	14041-10001-23569	16836 W BOSQUE DR	91436	5	165B133   247	2291003005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.14957	-118.49954	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 22.34 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(88) MODULES: KYOCERA  KD255GX-LFB3(3) SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16191	11041-10000-07146	1605 W CARSON ST	90501	15	051B193   911	7349033034	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM			PC Info Complete	06/20/2011 12:00:00 AM	ADDRESS	33.83165	-118.30675	Ti in a store inside the Gas station. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16192	19041-20000-14084	8709 W GUTHRIE AVE	90034	10	126B169   683	4302025027	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.04133	-118.38182	INSTALLING A NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 5.8KW DC/5KW AC. SCOPE OF WORK INCLUDES (20) PV MODULES WITH P320 OPTIMIZERS, AND A SE5000H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16193	17041-20000-28119	12261 N LIMA WAY	91342	7	219B149   935	2611046027		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.29407	-118.45611	pv1install roof mountrd pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16194	14041-10000-02013	2126 W ADAMS BLVD	90018	10	123B193   653	5052032010	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM			Reviewed by Supervisor	02/04/2014 12:00:00 AM	ADDRESS	34.03248	-118.31281	"Plan check for 2"" conduit run to new 40 hp motor in hazardous location. 16"" x 16"" x 8"" pull box.submitted after jan 1, 2014; subjected to 2011 NEC for compliance.NOTE: investigation fee pending to be paid"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16195	19041-20000-25316	1801 W OLYMPIC BLVD 3rd Floor	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.05046	-118.27663	Plan check for Title 24 only. Project site is a breakroom on the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16196	11041-10000-26593	1308-1312 S ABBOT KINNEY BLVD	90291	11	108B145  1289	4238004015	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	33.99095	-118.46787	POWER AND ENERGY. NEW 600A SERVICE, EQUIPMENT, PANELS, AND BRANCH CKTS FOR RETAIL. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16197	17041-20001-24226	12811 W FOOTHILL BLVD	91342	7	216B161    22	2514004029	M1-1-CUGU	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	34.29241	-118.41375	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 68.3 KWapplicant to provide building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16198	16041-20000-30707	535 S ALEXANDRIA AVE 1-106	90020	10	135B197   933	5502019017	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			08/29/2016 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.06426	-118.2981	Plan check for roof-mounted solar array on apartment building. 38kW ungrounded system (7.6kW*5).(150) 340W pv modules. Each module has a 300W power optimizer. Interconnect with line side tap on 400A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16199	16041-20001-22312	7024 W SHADYGROVE ST	91042	7	201A201   127	2564007001	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.24705	-118.28399	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16200	19041-10000-18041	19001 S HARBORGATE WAY	90501	15	060B193   440	7351021043	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	33.85763	-118.30375	REPLACE INDOOR AND OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16201	19041-10000-27517	8415 N LANKERSHIM BLVD	91352	6	192B169   408	2633030002	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1218.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.22323	-118.38797	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16202	13041-10000-24460	8382 N FAUST AVE	91304	12	192B097   225	2004004033	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.22239	-118.62017	PV1. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE 5.25 KW. 21 MODULES. CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16203	14041-20000-11809	2100 N ECHO PARK AVE	90026	13	144A211   143	5420035030	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.0895	-118.24984	Additon of new restroom and kitchen in front and back of the unit with lighting plan and title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16204	11041-10000-22387	6303 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM			PC Approved	10/19/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	T.I. to an existing office building.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16205	18041-10000-08078	3060 W OLYMPIC BLVD #  150	90006	10	129B193   321	5080030044	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.05239	-118.30229	PLAN CHECK FOR POWE AND ENERGY FOR - FIRST TENANT -BON SEAFOOD MARKET- IN RETAIL SPACE -  NEW 225KVA TRANSFORMENT CONNECTED TO EXISTING 1200A MAIN DISTRIBUTION BOARD FEEDING NEW PANELS(600A, (2)200A, 100A)TOTAL AFFECTED AREA = 6635 SQ. FT.EXISTING MAIN SERVICE = 4000A 480/277V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16206	18041-10000-06903	10052 N NOBLE AVE	91345	7	204B145   834	2660024009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.25317	-118.46077	Install new rooftop solar system on SFD, 4.93kW DC system. (17) modules with 17 P320 optimizers, (1) inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16207	11041-10001-02534	2000 S CENTRAL AVE	90011	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Apartment			02/10/2011 12:00:00 AM			PC Approved	02/10/2011 12:00:00 AM	ADDRESS	34.02249	-118.25156	INSTALL ADDITIONAL FIRE ALARM DEVICES TO EXISTING SYSTEM.    PERMIT WAS ISSUED UNDER 11041-10000-02534.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16208	17041-10000-45952	6750 N ETON AVE	91303	3	180B105    21	2148030037	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Issued	12/22/2017 12:00:00 AM	ADDRESS	34.19317	-118.59524	REPLACE METAL INDOOR HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16209	17041-20001-15819	21820 W BURBANK BLVD Ste 150	91367	3	174B105    44	2146007121	PK(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	ADDRESS	34.17228	-118.6032	5.25.2017 - Plan check for modifications to approved set. Revising lighting plan. Updated T24 documents to reflect changes. Changes clouded delta 1.=======TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16210	18041-10000-23746	1174 S LA BREA AVE	90019	10	132B181  1219	5084021016	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	07/25/2020 12:00:00 AM	ADDRESS	34.054	-118.3433	PC FOR POWER AND ENERGY FOR NEW ELECTRICAL  SERVICE SUPPLIED BY OTHER BUILDING. SCOPE INCLUDES NEW SERVICE PANELS, EQIPEMNT AND LIGHTS. TOTAL AFFECTED AREA 2262 SQ.FT . existing retail TIB# 18016-30000-19305	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16211	14041-10000-13412	5901 S NORMANDIE AVE	90047	8	105B193   164	6002011037	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.01	Electrical	Electrical	Apartment			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Issued	05/20/2014 12:00:00 AM	PIN	33.98728785	-118.30041591	NEW SERVICE AND PANELBOARDS AND TITLE 24 FOR 5-TENANT SPACES AND EXISTING MARKET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16212	14041-20000-02678	910 W JEFFERSON BLVD	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.024	-118.28511	T24 FOR CONTROLS ONLY FOR PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16213	10041-20001-20977	3900 N STANSBURY AVE Triangle-Building	91423		162B153   353	2274027003	RE40-1-H		Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES		Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM			PC Approved	06/14/2011 12:00:00 AM	ADDRESS	34.14084	-118.44264	Plan check power and energy for Delta 3 & 4 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16214	18041-20002-03679	12143 N DELANTE WAY	91344	12	219B125    73	2601073004	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.29421	-118.5277	3/19/19changes to an approved set of plans.  changes to relocate existing equipment to match field conditions.this is plan check only. ((((PV1.  Install 3.8 kW roof mounted PV system with (14) modules and 13.5 kWh energy storage system on 300A rated 240/120V residential service.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16215	15041-20002-43906	7929 S FORDHAM ROAD	90045	11	099B157    80	4113021004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2016 12:00:00 AM			PC Approved	04/08/2016 12:00:00 AM	ADDRESS	33.96654	-118.41889	4.8.2016 - Plan check for modifications to approved set. Change location of Solar Load Center. Changes clouded.====Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (21) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16216	19041-20001-34636	3030 N SURRY ST	90027	4	153A203   332	5434019010	R1-1	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	34.11201	-118.27395	09-19-2019 Changes to an approved set of plan, Changes include addtion of Disconnecting means and upadate drawing as built. All Changes has been clouded.  Plan check onlyFees $0.00 Due California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16217	18041-10001-43575	7831 W 79TH ST	90293	11	099B153   135	4114006014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM			PC Info Complete	11/21/2018 12:00:00 AM	ADDRESS	33.96348	-118.43433	FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED PV SYSTEM(10KVA AC/13.12DC) CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 41 MODULES USING P320 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16218	19041-20000-27860	18735 W LISBURN PL	91326	12	219B121   169	2870002012	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Issued	07/19/2019 12:00:00 AM	ADDRESS	34.29516	-118.54203	Plan check for PV roof mounted and Energy Stroage System, PV system size: 8.19KW with 26 PV modules and 1 inverter(7.6KW) and Energy Storage System Size: 40.5KWh with 3 Tesla PowerWall 2.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16219	18041-10000-31214	3050 W PICO BLVD	90006	10	129B193  1323	5074001007	C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.04699	-118.30766	Energy plan check for a NEW CONSTRUCTION ( AUTOMOBILES SALES BUILDING ). Scope includes new lighting and equipment with a total area of 5872-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16220	14041-20000-00751	17751 W STRATHERN ST	91335	12	189B129   438	2101003007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.21577	-118.52052	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16221	14041-10000-06168	450 S SEATON ST	90013	14	127-5A215 375	5163025009	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Public Safety Only			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Issued	03/06/2014 12:00:00 AM	ADDRESS	34.04196	-118.2373	NEW FIRE ALARM PANEL AND A DEVICE FOR A COMMERCIAL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16222	15041-20001-15348	3712-3714 S KELTON AVE	90034	5	117B161   560	4252025033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	34.01778	-118.41289	05-27-16 Changes to an approved set of plans. Changes include service entrance from underground to overhead service. ***********Previous work description**********************Plan check for 16 appartment units with 800A service	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16223	16041-10000-07441	1445 W BRETT PL	90732	15	021B193    31	7445004900	R3-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Expired	04/03/2018 12:00:00 AM	ADDRESS	33.75651	-118.30869	Replace Fire alarm panel and RPS, all other devices are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16224	14041-20000-11742	412 E BOYD ST	90013	14	129A213   335	5147006002	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.04622	-118.24229	Replace of FC and HVAC units with load exceed 400A.  New lighting in common areas.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16225	17041-10000-15695	3137 S LA CIENEGA BLVD	90016	10	123B173  1581	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM			PC Info Complete	05/10/2017 12:00:00 AM	ADDRESS	34.0298	-118.37263	PC FOR TI IN OFFICE SPACE. TITLE 24 ENERGY ONLY.TOTAL AFFECTED AREA 588 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16226	17041-10000-34117	21550 W OXNARD ST 400	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.179	-118.60001	TITLE 24 PLAN CHECK ONLY FOR INTERIOR TI FOR (NEW RECEPTION AREA, FIVE NEW OFFICES) WITHIN EXISTING HIGHRISE BUILDING. TOTAL AFFECTED AREA 4973	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16227	15041-20001-04446	3700 S GRAMERCY PL	90018	8	120B189  1604	5042018009	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM			PC Approved	02/27/2015 12:00:00 AM	ADDRESS	34.02094	-118.31351	[[[[ Plan check only change from 20 modules micro-inverter to 16 modules micro-inverter]]]]]PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.3kW. Ungrounded system.(20) EnPhase M215-IG microinverters with (20) 250W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16228	14041-10000-36049	3606 W WASHINGTON BLVD	90018	10	126B189   974	5060022002	[Q]CM-1VL-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.03969	-118.32392	Plan check for Title-24 only. T.I. for Print shop. Total area: 6215SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16229	15041-10000-14183	6751 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	33.93208	-118.40881	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16230	07041-10002-26024	1401 S KELTON AVE 10968-Wilkins	90024		132B153   980	4324038004	[Q]R4-1L		Westwood				Electrical	Electrical	Apartment			02/11/2011 12:00:00 AM			PC Approved	02/17/2011 12:00:00 AM	ADDRESS	34.054	-118.44347	Delta 1 mofdifications to plans approvded and permitted on application # 07041-10001-26024. (((((((((((((((Resubmit Expired Plans))))))))))         New 5-story 24-unit condominium building with 2 levels of subterranean garage.  New 120/240V 3ph 4W 2000A service. Buildinglocated in a methane zone.  EPC: Power and Energy(T-24).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16231	18041-10000-13476	5932 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Closed	04/24/2018 12:00:00 AM	ADDRESS	33.94435	-118.38715	Plan check for power only. Project scope is the installation of an 800 kW genset to supply power to all areas of the United Airlines cargo facility until the servicing of the 4,000-amp LADWP service is completed. Service will be shut down during servicing. Load and short-circuit study will be required due to size of genset.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16232	18041-10000-10993	767 S ALAMEDA ST BLDG2-3RD FL	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	ALTERATIONS IN RESTROOMS ON 3RD FLOOR OF BUILDING 2PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16233	12041-10001-26555	21021 W ERWIN ST	91367	3	177B109     7	2149004007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			03/06/2014 12:00:00 AM			PC Info Complete	08/22/2014 12:00:00 AM	ADDRESS	34.18304	-118.59175	Revision to the approved plan. Addition of 30 new ckts and change the T24. All the changes are identified by delta2.  Permit is existing , this is plan check only.    ((((((((((((((((((((NEW 5 STORY MULTI-FAMILY APARTMENT BUILDING (8 TYPICAL UNITS). THREE 3000A SERVICE SUPPLYING BUILDING LOCATED AT ATTACHED PARKING GARAGE STRUCTURE. PARKING STRUCTURE AND SWIMMING POOLS WILL BE DONE UNDER SEPERATE APPLLICATION. FIRE ALARM SYSTEM VARIANCE HAS BEEN FILED.)))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16234	18041-10000-06583	940 S HILL ST	90015	14	127-5A209 262	5139003017	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			Reviewed by Supervisor	03/09/2018 12:00:00 AM	ADDRESS	34.04195	-118.25786	PC  FOR POWER AND ENERGY TO Change of use and tenant improvement for Tesla Auto Sales and vehicle service. SCOPE INCLUDES NEW SERVIVCE (208/120V, 3P, 2000A), NEW EQUIPMENT, PANELS, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 31225 SQ.FT B# 18016-40000-05475	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16235	14041-10001-05555	3150 W WILSHIRE BLVD SUITE A	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	(((4/7/2014- CHANGES MADE TO APPROVED SET. CHANGES TO LIGHITNG ONLY. PERMIT TO BE PULLED ON THE MASTER APPLICATION)))PLANCHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR STARBUCKS. HIGHRISE. SUITE A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16236	17041-20000-39376	21534 W DEVONSHIRE ST suite e	91311	12	204B105   832	2747025037	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.25701	-118.60015	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor only.  total square footage 1120.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16237	17041-10000-34024	820 S WILTON PL	90005	4	132B189   709	5092026016	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			09/22/2017 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	12/01/2021 12:00:00 AM	ADDRESS	34.0573	-118.3141	POWER AND ENERGY ORIGINAL PLAN CHECK SUBMITTAL UNDER 16041-10000-15828 (M.Z PLAN CHECKER ) THIS SUBMITTAL INDICATES CHANGE OF ENGINEER OF RECORD, 2013 NEC AND T-24 FOR NEW CONSTRUCTION 18 UNIT APARTMENT. PERMIT FEES TO BE CALCULATED UNDER INSPECTION. *****PC FOR POWER AND ENERGY. Proposed three story V-A apartment building with 1 story and 1 level basement of  I-A  parking level. 6 TYPE UNITS.(A& A1 ARE ELECTRICALY IDENTICAL ALSO B1&B, AND C1 & C). TOTAL AREA  30909 SQ FT. 2500 A SERVICEB# 15010-10000-00196	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16238	19041-20000-31063	4070 N WILKINSON AVE	91604	2	165B165  1248	2367010014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.14484	-118.40401	Plan check for PV roof mounted system installed into existing system,  Additional PV System size: 1.9KW DC with 6 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16239	13041-10001-30917	11041 N SALT LAKE AVE	91326	12	210B121   525	2717002033	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.27021	-118.5444	Expedited RSES plan check per applicant request. (((PV1, Install 8 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 32 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16240	14041-20001-05183	4424 N BERGAMO DR	91436	5	165B137    59	2284016027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.15206	-118.48686	((EXPEDITE FEES))PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 18.9KWAC. (E) 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16241	14041-20001-35060	7918 N CRANER AVE	91352	2	189B173   374	2409005018	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	01/26/2015 12:00:00 AM	ADDRESS	34.21443	-118.36911	EXPEDITED PER CUSTOMER REQUEST.PV1. INSTALL ROOF MOUNTED P V SYSTEM SIZED 7.0KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(22) SUNPOWER 327W MODULES(1) SMA SB7000TL INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16242	13041-10000-28075	4550 W PICO BLVD C314	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	CRA CLEARED IN 12041-10000-27812. INVESTIGATION FEE HAS TO BEEN ADDED TO THE FINAL FEES.FIRST TIME TENANT  GNC AT THE MID-TOWN CROSSINGINITIAL PLAN CHK IS FOR TITLE 24 ; THIS APPLICATION IS FOR FULL PLAN CHECK FOR THE POWER INSTALLATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16243	17041-20000-28092	12251 N LIMA WAY	91342	7	219B149   930	2611046022		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.29401	-118.45567	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16244	14041-10000-13184	7448 N MILWOOD AVE	91303	3	186B105   426	2112010006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.206	-118.59415	PV1, INSTALL A 11.55 KW DC ROOF-MOUNTED SOLAR ARRAY. INTERCONNECT WITH SERVICE PANEL. TRANSFORMERED. LOW PERMIT FEES DUE TO 2012 SENATE BILL NO. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16245	18041-10000-16837	8910 N MIKUNI AVE	91324	12	195B117    35	2783025098	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.23248	-118.56096	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16246	14041-10001-06133	7906 S NARDIAN WAY	90045	11	099B157    84	4113022028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	33.96646	-118.42043	EXPDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(21) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16247	16041-20000-23609	18901 W BALLINGER ST	91324	12	201B121   715	2762037046	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	09/03/2016 12:00:00 AM	ADDRESS	34.24403	-118.54513	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16248	16041-10000-17865	1150 S OLIVE ST 18TH FLOOR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE ON 18TH FLOOR. TOTAL AFFECTED AREA IS 14414 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16249	16041-10000-15806	4104 S LYCEUM AVE	90066	11	108B153   483	4230025001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	33.99306	-118.43688	PV1. PC ONLY FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(16)MODULES-SOLARCITY STANDARD(16)OPTIMIZERS-SOLAREDGE #P300(1)INVERTER-SOLAREDGE #SE3800A-US-ZB-UNOTE:CLEARANCE AND PERMIT PAID UNDER PCIS#16041-90000-14276	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16250	13041-10000-33048	12476 W TIBBETTS ST	91342	7	228B165    62	2582029055	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.32139	-118.4055	PV1, Install 7 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE5000A-US. (28) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16251	11041-10000-15993	8707 N LINDLEY AVE	91325	12	195B125   821	2769019044	C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.22913	-118.52752	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16252	13041-10000-06985	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.07594	-118.35916	INSTALLATION OF NEW LIGHTING FIXTURES IN OUTDOOR CARPORT AREA. PC FOR T24 OUTDOOR ENERGY. TOTAL AREA 106525 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16253	15041-10000-38814	1151 1/2 N GULF AVE	90744	15	033B205   700	7415023017	[Q]RD2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Expired	03/27/2018 12:00:00 AM	ADDRESS	33.78583	-118.27352	PV2INSTALL ROOF MOUNTED PV SYSTEM USING A CENTRAL INVERTER SIZED 3.6KW. TOTAL SYSTEM SIZE IS 3.6.(1) 125A LOAD CENTER(16) KYOCERA 2656 MODULES(1) ABB PVI-3.6 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16254	13041-20000-25762	20224 W VIA MADRIGAL	91326	12	219B113   294	2701062009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	34.29646	-118.57349	ROOF MOUNTED PV SOLAR 9.9 KW on a single family dwelling.  Service load must be verified for derating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16255	19041-10000-43763	6652 N BERQUIST AVE	91307	12	180B093   279	2036002018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.19134	-118.63437	NEW PV1 INSTALLATION WITH A SYSTEM SIZE OF 5.27 kW DC/5kW AC WITH A SOLAR EDGE CENTRAL INVERTER (SE5000H-US), WITH 17 MODULES (S-ENERGY SN310M-15),  AND 17 (SOLAREDGE P320 OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16256	12041-20000-22543	17175 W VENTURA BLVD	91316	5	171B133   679	2258012022	[Q]C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			PC Approved	10/04/2012 12:00:00 AM	ADDRESS	34.16072	-118.5076	Change to lighting, receptacles, in a Yoga Studio.  Load is 282 Amps and occupancy load is 85 per plans.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16257	13041-10000-23030	1990 S WESTWOOD BLVD SUITE 130	90025	5	129B153   910	4321011085	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/23/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	34.04691	-118.43414	TITLE 24 PLAN CHECK ONLY. 3785 SQFT. EMERGENCY LIGHTING. 2 STORIES. MARTIAL ARTS GYM. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16258	14041-10000-24588	301 N ALMA REAL DR	90272	11	123B129   327	4411020022	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.03397	-118.5242	"PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 4.5KW DC. "" THE SOLAR PV INSTALLATION SHALL COMPLY WITH LOS ANGELES FIRE DEPARTMENSTS FIRE PREVENTION BUREAY (FPB) REQUIREMENT NO. 96 OR APPROVED PLANS BY THE LAFD""MAIN SERVICE 400 AMPS.(16) ENPHASE M215 MICROINVERTER(16) SOLARWORLD SW 250"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16259	18041-10000-11484	19515 S VERMONT AVE	90502	15	057B197    23	7351034023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	33.85325	-118.29073	PC FOR T-24, INSTALL (1) NEW WALK IN COOLER  AND  (1)  NEW WALK IN FREEZER IN WAREHOUSE, NOT PRE FAB LIGHTING, CONTRACTOR TO INSTALL NEW LIGHTING. TOTAL SQ. FT. 2160.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16260	14041-20000-29071	8118 N JUMILLA AVE	91306	3	189B117   130	2106014018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.21736	-118.56324	PV1Using standard plan. Install roof-mounted solar array on SFD. 2 inverters with 2 strings each. System size: 7.8kW. 2 strings on detached garage, and 2 strings on house.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16261	08041-20005-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Approved	01/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to previously approved set of plans for DELTA 212 Only.  See #09041-20005-07787 for Panel schedules and load calc for DELTA 212.      <<<<NEW HIGH RISE BUILDING - MEDICAL OFFICE (SHELL ONLY)VARIANCE FOR DEFERRED APPROVAL OF FIRE ALARM SYSTEM WAS SUBMITTED.P/check is approved subject to the ""Conditions of Approval"" on a request for modification regarding campus style feeder to a fire pump.>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16262	19041-20001-23996	15030 W BLEDSOE ST	91342	7	222B145    15	2506015016	(T)R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	34.30963	-118.46019	Revision to approved plans.  200A load center removed from project scope - interconnection point changed to upgraded main service panel.  (((Plan check for PV roof mounted and energy storage system, PV system size: 9.9 KW  and 1 Tesla 13.5KWh. with 30 PV modules and 1 inverter(7.6KW).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16263	08041-20001-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Closed	02/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	BULLETIN # 56,56.1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16264	17041-20000-25333	11335 W MOORPARK ST	91602	2	165B173   310	2366004036	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.15052	-118.37812	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MASSAGE ROOMS. 1075 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16265	16041-20000-45764	3121 W BEVERLY BLVD	90057	13	138A201   196	5156010011	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			PC Approved	12/30/2016 12:00:00 AM	ADDRESS	34.07224	-118.28277	Plan check for energy only. TI and change of use from restaurant to bar/lounge. New lighting (incl. emergency). 1,195sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16266	15041-20000-30083	14651 W WYANDOTTE ST	91405	6	186B149   735	2218018019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.20312	-118.45278	Plan check for a PV1 roof-mounted PV system. System size is 8 kWac and consists of (2) inverters, (23) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16267	10041-20000-20314	6640 W ROMAINE ST	90038	4	144B185   970	5532014901	PF-1XL	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM	12/02/2010 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.08875	-118.33461	Compressed gas facility.  Install new 800 amps service, switchboard, panels, branch circuits, compressor unit, and outdoor lighting.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16268	15041-20002-35922	10450 N DE SOTO AVE	91311	12	207B109   628	2706015033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	34.26047	-118.58835	02/24/2016 Changes to an approved set of plans. Changes have been made to reflect on-field installation. Changes include clarifications about the main service panel and updated service load calcs.*****Previous Work Description*****PERMIT FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.Plan check for a PV1 roof-mounted PV system. System size is 13 kWac and consists of (2) inverters, (48) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16269	10041-20000-11524	16255 W VENTURA BLVD #110	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	08/18/2010 12:00:00 AM	ADDRESS	34.15711	-118.48768	Plan check T-24 Energy (geneal/emergency) lighting for office TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16270	18041-10000-31968	1479 S LA CIENEGA BLVD 1-20	90035	5	129B173   521	4303033014	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.05096	-118.37644	Remodel of an existing 1-story motel to convert existing 19 guestrooms and manager's unit to lighthouse keeping units. Plan Check for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16271	13041-10000-34346	5835 N SEPULVEDA BLVD	91411	4	174B145    67	2243001029	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.17657	-118.46647	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For autoshop (NON-HAZARDOUS PER APPLICANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16272	17041-10000-04353	733 N KINGS ROAD 1-189	90069	5	141B173   318	5528002019	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.0845	-118.37197	Upgrading to new fire alarm system in a 3 story apartment building. (10) Fire Alarm, (477) Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16273	19041-30000-21068	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.0834	-118.37568	Plan check for a fire alarm system for a 2-story commercial building. Scope of work is the relocation of the FACP and the addition of (26) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16274	16041-10000-34559	3061 N TREADWELL ST	90065	13	156B209   287	5458005034	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.12066	-118.24886	PC FOR ENERGY ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. INDOOR + OUTDOOR LIGHTING AREA 94950 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16275	16041-30000-14594	601 S FIGUEROA ST #3575	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check energy Title 24 only in existing space T.I.  Total area:  540 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16276	18041-20002-06702	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM			PC Info Complete	12/04/2018 12:00:00 AM	ADDRESS	33.98722	-118.47211	12-04-2018 Changes to an permitted set of plans. Changes include addtional building facade lighting, and sign lighting, addtion of square footage of 555 Sq ft for lighing calculation. All Changes has been clouded as delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16277	11041-20000-20839	8551 N FAUST AVE	91304	12	192B097    37	2004013003	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	12/08/2011 12:00:00 AM	ADDRESS	34.226	-118.62051	New 9.03 KW roof mounted PV system on a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16278	17041-20000-10092	4001 N RESEDA BLVD	91356	3	162B121    10	2177032021	A1-1	South Valley	Encino - Tarzana	Tarzana	Yes	1398.01	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.14334	-118.54091	TI to an existing country club.  Newly connected load exceeding 400 Amps.  Plan check for power and energy.  Total lighting area 1590 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16279	12041-10000-14929	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Issued	08/07/2012 12:00:00 AM	ADDRESS	34.21585	-118.47965	addition of two refrigeration skids, removing two old ref. skids, in exiting one story bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16280	18041-10000-26817	9857 N MASON AVE	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.24955	-118.58012	PLANCHECK FOR POWER AND ENERGY. OUTDOOR LIGHITNG AND EV CHARGERS. BUILDING PERMIT # 18010-10000-01049 CORE AND SHELL FOR NEW 1-STORY TYPE VB  RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16281	11041-10000-19354	15233 W LA CRUZ DR	90272	11	129B125   734	4412002016		West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	ADDRESS	34.04577	-118.52516	PHOTOVOLTAIC SYSTEM, ENPHASE MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16282	18041-20000-07669	4816 S LONG BEACH AVE EAST	90058	9	111A213    70	5106009044	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	33.9997	-118.24299	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16283	19041-10000-45821	10714 W KURT ST	91342	7	213B177    55	2529016006	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.27913	-118.36449	PV1. LADWP Community Solar Program: 9.00KWdc / 8.96KWac - 32 solar modules and 32 enphase IQ6-60-2-US micro-inverters. 1 service interconnected as a new service drop 100A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16284	13041-20000-13666	3515 W WILSHIRE BLVD FLR 3-FLR 12	90010	10	132B193    16	5502032017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	ADDRESS	34.0619	-118.30094	T24, ENERGY ONLY. PC FOR EMERGENCY LIGHTING AND ENERGY COMPLIANCE IN CORRIDOR. 18060 SQ FT. WORK DONE FOR CORRIDOR LIGHTING 3RD - 12TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16285	12041-10000-16771	360 S MAPLETON DR	90024	5	138B157    25	4359013024	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2012 12:00:00 AM			PC Info Complete	09/17/2012 12:00:00 AM	ADDRESS	34.07629	-118.43071	PLAN CHECK FOR EXISTING SINGLE FAMILY DWELLING REMODEL WITH NEW 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16286	14041-20000-31024	14624 W SHERMAN WAY #101	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	34.20102	-118.45165	Change of use from office to medical lab.  Install general/emergency lighting on 1st floor.  Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16287	15041-10000-32679	818 W 7TH ST STE 740	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.04895	-118.25943	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING SUITE 740 (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING TO AN OFFICE AND NEW RECEPTACLES. TOTAL AREA IS 1120 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16288	18041-10000-08400	3939 S FIGUEROA ST L200	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	PC for power and energy for retial Team Store first time tenant in LAFC stadium. Installing new lights, receptacles and equipment. Total area 5020sqft. B# 17016-10000-35611. NOTE:Per insp Mike Packard 's instruction, plan was accepted for plan check even though shell and core permit has not been finalised	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16289	18041-20001-37685	7945 N BALBOA BLVD	91406	6	189B133   476	2204024014	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM			PC Approved	10/07/2018 12:00:00 AM	ADDRESS	34.21512	-118.50149	Expedite per applicant requestPlan check for PV roof mounted system, system size: 23.76KW DC, 22.19KW AC with 72 PV Modules and 2 inverters(10.0KW) connected to 400A panel supply side connection	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16290	12041-10000-29825	504 W OLYMPIC BLVD	90015	14	127-5A207 191	5139008016	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	12/11/2012 12:00:00 AM	ADDRESS	34.0431	-118.26104	Tenant improvement and change of use of existing take-out restaurant to new convenience store. Remove non bearing walls and build new walls.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16291	18041-10001-15830	1547 N HAZELWOOD AVE	90041	14	157-5A221 268	5474012002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.12437	-118.2147	CHANGES TO APPROVED SET OF PLAN - CHANGES INCLUDE UPDATE TO UTILITY METER ONLY ON SINGLE LINE DIAGRAMORIGINAL PERMITPV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (17) MODULES WITH OPTIMIZERS AND (1) INVERTER 3.8KWAC. TOTAL SYSTEM SIZE IS 3.8KWAC, 5.185 KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16292	18041-10000-20011	1375 N VINE ST BLG A	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM	ADDRESS	34.09602	-118.32703	NEW FIRE ALARM SYSTEM IN A NEW COMMERCIAL BUILDING.BUILDING PERMIT #15010-10000-04706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16293	19041-20001-19944	13900 W POLK ST	91342	7	228B153   466	2503007019	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.31944	-118.43621	Expedited plan check fee.PV1.  Install 10.23 kW DC / 8.69 kW AC roof mounted grid tied PV system.  (31) modules with 3.8 and 7.6 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16294	16041-10000-05401	22222 W VICTORY BLVD BLDG C	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUNDRY ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16295	14041-10000-34839	2114 N COLDWATER CANYON DR	90210	4	150B165    86	4388008022	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.11037	-118.40455	Installation of new roof mounted solar PV array.  Total system size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16296	17041-10001-33475	11922 W FOOTHILL BLVD	91342	7	210B165   107	2532012038	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.27524	-118.3962	*SEE APPLICATION NOTES. PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES ADDITIONAL PANEL TO THE APPROVED SET.TOTAL CONNCETED LOAD >400A.NOTE THAT BUILDING IS SERVED BY TWO EXISITING800A SERVICES CONNECTED TO THE SAME SERVICE EQUIPMENT WITH TWO DIFFERENT PULL SECTIONS.PC for T24 only for altereration in lighting system for TI. Installing new circuits, equipment and lighting. Load <400A.Total of 3300 sqft.Build# 17016-10000-27114	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16297	13041-10000-26051	1545 N RENDALL PL	90026	13	144A205   372	5425017014	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.08812	-118.26999	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 2.385KW DC IN A 2-STORY HOME. NON-STANDARD PLAN ; USING OPTIMIZERS.(9) MODULES: SUNIVA # OPT265-60-4-1B0 BLACK(9)SOLAREDGE #OP300-MV-AH4SM-2NA-Z(1)INVERTER: FRONIUS V 10.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16298	15041-20000-18506	19207 W VICTORY BLVD #2	91335	3	180B121   522	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.18674	-118.55154	Plan check for PV roof mounted system. System size: 4.0kW with 10 modules and 1 inverter (4.0kW) connected to 125A unit panel and connected to Meter Bank(600A)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16299	15041-20000-37730	21031 W VENTURA BLVD Suite 921	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	PIN	34.16717222	-118.59179488	Plan check for energy only. TI to existing office on 9th floor of high rise office building. New lighting (incl. emergency) and receptacles. 2,091 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16300	19041-10000-18360	7538 W OWENS ST	91042	7	207B197   682	2557012044	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.26403	-118.29652	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 MODULES (LONGI SOLAR 305) , 20 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 6.1KWdc and 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16301	17041-10000-34616	11640 W SAN VICENTE BLVD	90049	11	129B145    38	4265005033	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.05369	-118.46307	PC for T24 only for restuarant TI. Installing new receptacles, lights, equipment in existing panel. Total of 1270sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16302	19041-10000-51256	4330 W SLAUSON AVE	90043	8	108B181   323	4019004044	C1.5-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	33.98869	-118.35118	Replacing Existing Outdoor HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16303	14041-20000-15980	6303 N OWENSMOUTH AVE #392	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.18474	-118.60182	T.I. to a partial existing high rise building on 10th floor.  Install general/emergency lighting in the office area.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16304	18041-20000-37306	20707 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.29314	-118.58498	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16305	13041-10000-36264	1154 S CROCKER ST	90021	14	124-5A211 348	5132010053	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.03342	-118.25122	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 481 SQ FT. REPLACING TOTAL OF 3 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16306	16041-10001-04435	3889 N WEST POINT DR	90065	1	145-5A223 238	5451022013	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM			PC Approved	04/21/2016 12:00:00 AM	ADDRESS	34.09276	-118.21314	Changes to approved set.  Relocate inverter in solar system.  Plan check requested by inspector.PV1 rooftop solar installation 5kWac system. Total system size is 5.0kWac.(17) MODULES-SW280 Mono(1) INVERTER-SOLAREDGE SE5000A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16307	14041-10000-14239	2700 S ARMACOST AVE	90064	11	120B153   846	4257016041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.02373	-118.4445	PV1, INSTALL 5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH POWER OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16308	14041-10000-00620	451-467 N WESTERN AVE	90004	4	141B193  1292	5522018012	C2-1	Central		Wilshire Center - Koreatown		1924.20	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.07953	-118.30933	INSTALLATION OF NEW OVERHEAD SERVICE FOR (E) MIX USE BUILDING ( 8 RETAIL STORES & 24 APARTMENTS ) . (8) NEW SUBPANELS, NEW FEEDERS. BRANCH CIRCUITS ARE ALL EXISTING IN PANELS PER APPLICANT. NOTE: SUBMITTED AFTER 01/1/2014; THIS PLAN WILL BE SUBJECTED TO THE 2011 NEC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16309	19041-10000-32983	444 S FLOWER ST 47TH FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	07/31/2021 12:00:00 AM	ADDRESS	34.05189	-118.25546	Energy plan check for an office T.I located on the 47th floor of a highrise building. Scope includes new lighting and equipment with a total lighting area of 12,930-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16310	19041-20000-18573	424 N FIRMIN ST	90026	1	135A211   126	5160022012	CW	Central	Westlake	Echo Park		2080.00	Electrical	Electrical	Apartment			05/16/2019 12:00:00 AM	10/30/2020 12:00:00 AM		Permit Finaled	02/14/2023 12:00:00 AM	ADDRESS	34.06486	-118.25373	2000A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residentail construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16311	13041-10000-29520	9736 N OAKDALE AVE	91311	12	201B113   526	2761020035	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.24729	-118.56675	PV1.  Install 4 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: power-one aurora pv1-3.6-ou td-s-us.  16 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16312	17041-30000-09909	19331 W BUSINESS CENTER DR	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.23118	-118.55466	Installation of new fire alarm system in existing single story commercial medical building.  Total system size = 80 devices + 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16313	18041-10000-26170	310 E HARRY BRIDGES BLVD	90744	15	027B209   220	7440005028	[Q]M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.77127	-118.25874	REPLACE INDOOR/OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16314	19041-10000-00775	10514 W DUNLEER DR	90064	5	123B161   360	4318037028	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.03512	-118.41433	PLAN CHECK FOR A 15.2 KW AC/ 18.6KW DC ROOFMOUNTED SYSTEM WITH (60) MODULES (2) SE7600 INVERTER, AND (60) P320 OPTIMIZERS INTERCONNECTING THROUGH THE SPLIT BUS MAIN SERVICE AND (1) 200A SUB PANEL$0 PERMIT FEE DUE TO SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16315	18041-10001-05439	6101 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Approved	04/11/2018 12:00:00 AM	ADDRESS	33.93236	-118.39253	[[[[4/11/18 CHANGES TO APPROVED SET. DELTA 1 CHANGES. PLANCHECK ONLY. CHANGES TO THE LIGHTING LAYOUT]]]]PC FOR TI-24 ENERGY ONLY FOR INTERIOR OFFICE TI ON 2ND FLOOR OF EXISTING KOREAN AIR CARGO FACILITY.INSTALLING NEW PANELS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 13640 SQ.FT. B#17016-10000-37641	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16316	16041-10000-01449	710 S LA BREA AVE	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.06164	-118.34397	01/14/16CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE CHANGE OF CONTROLS TO A  TIME CLOCK.  APPROVED SET WAS UNDER APPLICATION #14041-10000-25060(((NEW T.I.  TENANT IMPROVEMENT TO (E) RETAIL SPACE. PC FOR POWER AND ENERGY)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16317	11041-10000-22232	1555 N GORDON ST	90028	13	148-5A191 299	5545007019	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	07/17/2013 12:00:00 AM	ADDRESS	34.09966	-118.31978	NEW 4-STORIES, 21-UNITS APARTMENT BUILDING WITH 1-GARAGE LEVELVARIANCE IS FILED TO SEPARATE THE FA PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16318	14041-10000-23435	6149 W 83RD PL	90045	11	099B165  1229	4107027034	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	33.96305	-118.39314	Installation of new roof mounted solar PV array.  Total system size = 4 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16319	16041-20000-42039	333 S GRAND AVE 37th Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	"Plan check for power and energy. TI to office on 37th floor ~23,800sqft. New lighting (incl. emergency) and receptacles. New distribution load >400A.Plan is shared with application #16041-20000-42046 for the 38th floor.Applicant has only preventative maintenne information for ""emergency circuit"" with added connected load for both 37th and 38th floors. Based on provided information(replacement of emerency lighting for two floors). Client does not have to comply with 220.87 for emergency power per Supervisor Francis Ysaguirre."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16320	14041-10000-23101	1037 S WALL ST	90015	14	124-5A209  40	5145019019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.03687	-118.25404	PLANCHECK FOR T24 ENERGY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. 945 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16321	13041-10000-26745	5807 S AVALON BLVD	90011	9	108B205  1107	5101006005	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	33.98959	-118.26538	PLAN CHECK IS FOR EXTERIOR AND INTERIOR LIGHTING (MINIMUM) SYSTEMSINPREPARATION FOR LEASING NEW BUILDING((((((( 9500 sq ft shell building for future dialysis clinic with medical office.  Existing 800A service per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16322	14041-10000-25190	639 S BROADWAY	90014	14	129A211   230	5144003040	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.04587	-118.25309	"TI in an existing office area on the 8th floor.Plan Check for T-24 Energy Calcs. Permit for replacing existing panels and new circuits. 38 Network & Data outlets covered under ""Misc"" Permit."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16323	11041-20000-27240	12643 W SHERMAN WAY	91605	2	183B161    12	2324003046	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM			PC Approved	12/21/2011 12:00:00 AM	ADDRESS	34.20136	-118.40837	T24 lighting plan check for remodeled restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16324	15041-20000-03205	927 S GENESEE AVE	90036	4	132B177   539	5086019006	R1-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.05869	-118.36049	pv1install roof mounted pv system sized 5.0kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16325	16041-10000-28525	5855 W CENTURY BLVD FLR 18	90045	11	090B169    11	4125025039	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	33.94572	-118.38488	T-24, PC FOR ENERGY ONLY. INTERIOR TI ON 18TH FLOOR OF THE MARRIOT HOTEL. CONVERT 3 EXISTING HOTEL EXECUTIVE SUITES INTO GUEST LOUNGE. SCOPE INCLUDES NEW LIGHTS AND RECEPTALCES. TOTAL AFFECTED AREA IS 4391 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16326	19041-10000-41874	2138 N HILLHURST AVE	90027	4	153B197   639	5590001035	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Info Complete	05/21/2020 12:00:00 AM	ADDRESS	34.11116	-118.28727	FULL PLAN CHECK FOR A TI FOR A FIRST TIME TENANT OUT SHELL RESTAURANT SPACE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 2846 SQ.FTB#19016-10000-30708	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16327	15041-10001-27152	19414 W OLIVOS DR	91356	3	168B117   213	2175007011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.15786	-118.55549	EXPEDITE ROOF MOUNTED PV SYSTEM.(((PV1. ROOF MOUNTED ON EXISTING RESIDENTAL SINGLE FAMILY HOME.  SYSTEM SIZE IS 12.6KW. MAIN PANEL TO BE REPLACED 225 AMP MAIN PANEL(49) MODULES-REC SOLAR: REC 275TP(1) INVERTER-SOLAREDGE TECHNOLOGIES: SE5000 (240) W/ -ER-US(1) INVERTER-SOLAR EDGE TECHNOLOGIES: SE 7600A-US (240V))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16328	12041-20000-08159	201 S ALVARADO ST #321	90057	13	135A205   131	5154018019	C2-1	Central	Westlake	Westlake North		2085.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.0639	-118.27235	T.I. to medical office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16329	11041-20000-16215	1208 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/08/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29194	"New 3.23 KW PV solar equipment ( max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) System for an Apartment Bldg #1208"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16330	19041-10000-22740	19620 W VANOWEN ST	91335	3	180B117    17	2132002006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.19362	-118.5607	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16331	13041-20000-35094	14860 W ROSCOE BLVD	91402	6	192B149   421	2210003074	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.22131	-118.4572	PC FOR POWER AND ENERGY, MEDICAL OFFICE TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16332	18041-20000-09805	14554 W FRIAR ST	91411	6	178-5A151  19	2241005016	[Q]C1.5-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.18554	-118.45061	PLANCHECK FOR POWER ONLY. PLANCHECK ONLY. NEW 600 AMP SERVICE., SWITCHBOARD AND PANELBOARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16333	15041-20000-19955	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan checkTitle 24 only for T.I. in existig highrise office space. Total area: 13,119SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16334	18041-10000-04947	361 1/2 N LA CIENEGA BLVD	90048	5	138B173   140	4337012027	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM			PC Info Complete	02/09/2018 12:00:00 AM	ADDRESS	34.07776	-118.37679	Plan Check for energy only, T-24. Change of use from package food (retail) to small coffee shop. Scope of work includes new lighting and receptacles.  Total sq. ft.  654 s.f.B# 17016-30000-23097	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16335	16041-20000-40912	16535 W CHATSWORTH ST	91344	12	207B137   330	2680017016	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.26485	-118.49228	remove existing hid light fixtures and replace with led exterior lights.  This application includes fixtures in the soccer field which is t-24 exempt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16336	15041-10000-42084	20655 W PLUMMER ST	91311	12	201B109   322	2748040900	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.24287	-118.58369	TI TO ANIMAL SHELTER. NON HUMAN MEDICAL AREAS. PC FOR T24 ENERGY ONLY. PER BUILDING SUBMITTAL, ENERGY COMPLIANCE SHALL BE ACCORDING TO 2008 BUILDING EFFICIENCY STANDARDS. MINIMUM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16337	17041-20000-36582	340 S ARDMORE AVE 1-52	90020	10	135B193   379	5502001019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.06768	-118.3014	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 46 KW.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16338	16041-10001-20791	404 S FIGUEROA ST 35th-Floor	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.05326	-118.25596	11/01/16Revisions to an approved set of plans. All changes are made under delta 2. Changes include removing battery back-up from emergency light fixtures and using emergency generator and emergency branch circuit for emergency lights. <<<<<T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT ON THE 35TH FLOOR.  SCOPE INCLUDES NEW LIGHTS AND CONTROLS. TOTAL AFFECTED AREA IS 1532 SQ. FT.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16339	13041-10001-36027	13606 W MONTAGUE ST	91331	6	195B157   105	2625037034	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.23466	-118.42879	Expedited RSES plan check per applicant request.{{PV1, Install 5.75 kW DC roof-mounted solar array for a two story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (23) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16340	19041-20000-26341	12749 W VENTURA BLVD	91604	2	165B161   936	2375021022	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM			PC Approved	07/10/2019 12:00:00 AM	ADDRESS	34.1449	-118.41107	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy.permit fees covered under application number 19041-20000-19708this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16341	15041-10000-13547	4360 S SAN PEDRO PL	90011	9	114A205   456	5113018022	C2-1VL	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.00432	-118.27211	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  CHANGE OF USE FROM RETAIL TO DENTAL OFFICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16342	12041-10000-24101	5931 S WESTERN AVE	90047	8	105B193    94	6001014002	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	33.98678	-118.3091	SERVICE UPGRADE IN AN EXISTING BUILDING.  PLAN CHECK FOR POWER & ENERGY. TWO BUILDINGS IN ONE LOT.   (1 OF 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16343	11041-10000-18587	600 E 7TH ST #105	90021	14	126A213   176	5146033035	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.04044	-118.24675	CHG OF USE & T.I. [1840SF] FROM 2-RETAILS SPACE #104 & 105 TO ONE (SPACE #105) OFFICE FOR GROUP AND INDIVIDUAL  REHAB COUNSELING  (FOR ALCOHOL & DRUG ABUSE) WITH NO TREATMENT ON SITE _ HOURS OF OPERATION 7AM TO 11 PM _NO CHANGE TO PARKING [SEE COMMENTS]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16344	16041-20001-26766	401 S KINGSLEY DR 1-84	90020	10	135B193   432	5503010025	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.06692	-118.30302	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 40kW with176 modules and 4 inverters(10.0kW) connected to MSP}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16345	13041-10001-33103	1639 W 252ND ST	90710	15	036B193   207	7410019029	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	33.79587	-118.30567	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR SYSTEM. 1 STORY. SYSTEM SIZE: 3.18KW DC. TRANSFORMERLESS UNGROUNDED SYSTEM.(12) SUNIVA OPT265(12) SOLAR EDGE POWER OPT 250(1) SOLAR EDGE SE3000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16346	16041-10000-08594	536-548 W 127TH ST	90044	15	081B201   256	6132002022	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.91751	-118.28433	NEW METHANE METIGATION SYSTEM, LEVEL 5,  WITH (45) DEVICES AND (1) FIRE ALARM PANEL TO A  NEW 4-STORY 85 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16347	16041-10000-44944	3547 W CASITAS AVE LOT 9	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12082	-118.257	Plan check for Power 11 buildings SFD live work  3 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 9 of 11Note: Master Application Lot 9 type A1,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16348	10041-10000-23301	4376 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.00, 1953.00	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	07/08/2011 12:00:00 AM	PIN	34.09636699	-118.28547339	New Del Taco Restaurant. New servise, Panelboard and circuits. Plan check is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16349	05041-10005-03477	12475 BLUFF CREEK DR	90094	11	102B161  1149	4211010059	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	PIN	33.97754762	-118.40825973	pc under cp 2100 board previously approved.  this application is for adding  7 new water pumps .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16350	16041-10000-16243	2159 E BAY ST	90021	14	123A217   424	5166001002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.03156	-118.22794	PC for T-24. Tenant improvement for portion of an existing office building. Install new lightings and controlled receptacles . TOTAL AREA 2800 SQ FT.B# 16016-10000-03450	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16351	15041-20000-43765	5914 N NITA AVE	91367	3	177B101   203	2146022009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Closed	09/16/2016 12:00:00 AM	ADDRESS	34.17867	-118.61291	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (40) modules, (1) inverter, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16352	16041-20000-05442	13630 W SHERMAN WAY	91405	2	183B157    73	2328008023	C1-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.20103	-118.42997	PLANCHECK FOR POWER AND ENERGY. Change of use from Retail to Take-out restaurant (No Seating, (80.25' x 45.84')).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16353	12041-10000-30230	5857 S CENTRAL AVE	90001	9	108B209  1518	6007003902	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	SHOP BUILDING (RETAIL) . PLAN CHECK FOR power and energy, core & shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16354	14041-10000-06110	1307 N DOHENY DR	90069	4	144B169   125	4392010006	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.09412	-118.39231	PV1,INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(10) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16355	13041-10000-33510	7203 N RUBIO AVE 1-29	91406	6	183B137    51	2226016015	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.20163	-118.49594	New fire alarm system in new 4-story apartment building.  Fire Lite FACP MS9200UDLS.  110 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16356	15041-20002-40198	6260 N TOPANGA CANYON BLVD Parking	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.18497	-118.60418	[5/4/16 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGE OF MODULE TYPE TO JA SOLAR JAP6-72-350. CHANGES TO ROOF LAYOUT]]]0$ permit fees due to senate bill 1222Plan check for a PV2 roof-mounted PV system. System size 532 kWac and consists of (19) inverters, (5) load center, and (2166) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.Note: Building plans have been submitted under 15016-20000-26338	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16357	12041-20000-13330	334 S MAIN ST	90013	9	129A213   144	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.04841	-118.24668	Install general/emergency lighting in Dance Studio (Suite #1106).  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16358	13041-10006-34431	1243 S OLIVE ST	90015	14	126A207   200	5139023900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			08/18/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.03859	-118.26331	Changes to approved set.  All changes are clouded.  Unit panels are changing from fully rated to series rated circuit breakers.  Addition of new pool panel with associated loads.  Changes to location of lighting control panel and motion sensors.          POWER AND ENERGY PLAN CHECK FOR for New 7 Story (5 Story Type III-A over 2 Story Type IA Podium) Mixed Use Building w/293 Unit Apartment & Retail Building. Located in methane zone.ASSOCIATED BUILDING PERMIT: 13010-10001-02722	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16359	16041-20001-08117	3664 N WILLOW CREST AVE	91604	2	159B173    37	2380006006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.13615	-118.36756	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16360	12041-10000-16713	13069 W VICTORY BLVD	91606	2	180B161   789	2326017002	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM			Corrections Issued	10/08/2013 12:00:00 AM	PIN	34.18883938	-118.41818567	Plan check power and energy for LA Fitness remodel.  (Type A3  occupancy with more 100 occupants)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16361	12041-10000-08821	706 E 1ST ST	90012	14	129A215   100	5163003001	CM-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.04847	-118.2358	Beauty salon TI.  Load is less than 225A and occupany load is 20, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16362	18041-10000-47831	8885 W VENICE BLVD	90034	10	123B169  1393	4312010042	CM-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Issued	12/18/2018 12:00:00 AM	ADDRESS	34.02988	-118.38796	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16363	10041-20000-03711	5601 N DE SOTO AVE MOB-#W276	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.17126	-118.58861	North side MOB second  floor R.276 remodelEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16364	14041-10000-20177	8815 S SEPULVEDA BLVD	90045	11	096B165   974	4122035029	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	33.95677	-118.3965	permit to be pulled at EPC counter only. Plan check for energy only 2008T24.  Interior alterations only. BLDG#14016.30.08249: Change of use from bank to restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16365	16041-20001-30817	18840 W VENTURA BLVD	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	34.17186	-118.54425	12.2.2016 - Plan check for modifications to approved set. Change all breakers in MSA to fused disconnects. Downsize house panel feeder and fuse size; add main breaker to house panel to maintain series rating. Future tenant conduit feeds modified, updated load calculation. Reduce electrical room area, reduce number of light fixtures from 3 to 2, change light fixture from 40W to 48W -- update T24 documentation to reflect changes.======Plan check for power and energy. Project site is an existing commercial medical building. Project scope is a service upgrade to 1,600-amps and lighting within the electrical room. Total lighting area = 179 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16366	12041-20000-28770	15815 W MONTE ST	91342	7	225B141  1525	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.31113	-118.47563	first tenant commercial	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16367	18041-10000-10524	624 S GRAND AVE #825	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/14/2018 12:00:00 AM	ADDRESS	34.04802	-118.25572	Plan check for T24 only, TI on Ste. 825 (Data center), install new lighting and power using existing branch circuits in the area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16368	19041-20000-12309	19508 W GIFFORD ST	91335	3	186B117  1016	2116020019	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.20493	-118.5582	PV1.  Install 5.28 kW DC / 7.6 kW roof mounted grid tied PV system and 9.8 kWh energy storage system. (16) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16369	12041-10000-01982	540 S SANTA FE AVE	90013	14	126A217   221	5164004002	M3-1, PF-1XL	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.04042	-118.23057	new 2 story bldg, new fire alarm. 1 panel and 30 fa devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16370	16041-30000-19985	23958 W STRATHERN ST	91304	12	189B089   131	2020013040	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.21489	-118.65005	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16371	13041-20000-09460	881 N ALMA REAL DR #205	90272	11	126B125    97	4412009014	C2-1VL, P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.04497	-118.52525	DENTAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16372	08041-10003-24766	2332 S COTNER AVE	90064	5	123B153    38	4322023015	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM			PC Approved	02/08/2010 12:00:00 AM	ADDRESS	34.0371	-118.43727	Plan check power and energy (indoor/outdoor) for new 3 story office building with mezzanine.  New service, new MSB, new panel, new equipments, and new ckts.  ((((((((((((())))))))))) REVISIONS to already approved set of  plans.  No load changes, no lighting changes and T24 remains the same.(((((((((((((((((((((( 3 # 300 kcmil in 3 , 3 inch conduit changed to 2 sets of 3 1/2 inch conduit with 3 # 500 kcmil.)))))))))))))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16373	16041-20000-22204	21300 W VICTORY BLVD #505	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check Title 24 only in  existing office space. Total area: 758 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16374	17041-10001-02255	10053 N BARTEE AVE	91331	6	204B153   778	2645011026	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.2533	-118.43531	UPGRADE ELECTRICAL PANNEL 100AMP TO 200AMP	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16375	14041-10000-31885	13600 W MARINA POINTE DR	90292	11	105B153   610	4229018052	C4(OX)-2D, [Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Apartment			11/17/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	33.98473	-118.44411	FULL PLAN CHECK FOR APPARTMENT 20 METER BANK FOR FUTURE CAR CHARGING STATION WITH NEW DISTRIBUTION SWITCH BOARD (2500A) AND NEW TRANSFORMER 250KVA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16376	16041-20000-11961	15354 W STAGG ST	91406	6	189B145   572	2222010004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.21196	-118.46812	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (27) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16377	16041-20000-07612	2000 S AVENUE OF THE STARS 9th Floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for energy only. TI to existing office on 9th floor of high rise building. New lighting (incl. emergency) and receptacles. 4,452sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16378	18041-10000-22556	333 S HOPE ST 31ST FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Power and Energy on (E) office. TI with new loads >400A, total area: 22,907 sq.ft(B# 18016-10000-17788)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16379	15041-20000-44018	13206 N CRANSTON AVE	91342	7	225B161    79	2512024046	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.31163	-118.41753	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (12) micro-inverters and (12) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16380	18041-20001-00680	19351 W HATTERAS ST	91356	3	174B117    78	2153034031	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.17594	-118.55521	Expedited plan check fee. PV1.  Install 7.67 kW roof mounted grid tied PV system.  (26) modules with string inverter and energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16381	19041-20002-19952	7665 N SALE AVE	91304	12	189B097  1169	2013018006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM			PC Approved	07/22/2019 12:00:00 AM	ADDRESS	34.21021	-118.61883	7/22/2019changes to an approved set of plans.  changes to downsize system to 10.15KW AC.(35) modulesthis is plan check only.  ((((PV1.  Install 13.86 kW / 11.78 kW AC roof mounted grid tied PV system.  (42) modules with microinverters.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16382	17041-20000-27900	217 S AVENUE 20	90031	1	138A221   219	5447024008	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.07208	-118.21993	Plan check for a fire alarm system for a commercial building. Fire alarm system consists of (1) annunciator, (1) RPS, and (48) devices. System is tying into an existing FACP in the adjacent building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16383	18041-10000-46294	404 S FIGUEROA ST 2nd Flr	90071	14	130-5A209 238	5151020***	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM			PC Info Complete	12/06/2018 12:00:00 AM	ADDRESS	34.05326	-118.25596	Energy plan chekc for (3) meeting rooms located in the 2nd floor of an existing hotel T.I. Scope include new lighting and equipment with a total area of  3,259 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16384	18041-20000-07750	8121 W 3RD ST	90048	5	138B173   890	5511021024	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.07236	-118.36656	Plan check for Title 24 only. Project site is an existing tenant space in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,124 sq. ft.Note: Building application has been generated under 18016-30000-04722	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16385	13041-10000-05114	1667 W WASHINGTON BLVD	90006	1	126B197   655	5075021005	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM			Reviewed by Supervisor	04/04/2013 12:00:00 AM	PIN	34.04032567	-118.29364715	Electric service system consolidation for a commercial textile washer.  New service, switchboard, and power transformers.  Building is located in a methane zone.  Applicant (expediter) was unable to confirm whether undreground work was being performed or not.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16386	16041-20000-26981	9811 N FULLBRIGHT AVE	91311	12	201B113   360	2748009019	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.24842	-118.57813	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (2) inverters, (24) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16387	18041-20000-07896	10961 W OAK MOUNTAIN PL	91040	7	207B173   509	2528037017	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.26198	-118.36931	pv1install roof mountrd pv system sized 10kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16388	17041-10000-11979	4760 E VALLEY BLVD	90032	14	135A233   155	5223001004	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.06457	-118.18075	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 98575 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16389	17041-20000-21855	5555 W MELROSE AVE Bldg #166	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for energy only. TI to basement offices in building #166 (Paramount Studios). New lighting (incl. emergency) - 2366sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16390	14041-10000-14015	1647 W TEMPLE ST 1-49	90026	13	136-5A207 119	5159023017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Apartment			05/27/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.06861	-118.26247	Fire alarm system plan check.  49 unit existing apartment space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16391	13041-10000-04862	6150 W MULHOLLAND HWY	90068	4	159B189    76	5581020013	RE9-1	Central	Hollywood	Hollywood United	YES	1894.00, 1897.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	ADDRESS	34.12969	-118.32146	PV1 for 2 story single family dwelling. Transformerless system with optimizers. Total system size: 6.48kW. [Inverter: Solar Edge. Model#: SE6000-US] [Solar Module: Trinasolar. Model#: TSM-240 PC/PA05].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16392	16041-10000-10114	801 S FIGUEROA ST	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Issued	03/23/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	Adding 2 Control panels: Smoke Detector CP, and Annunciator CP to an (E) F.A. system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16393	11041-10000-04989	121 W 5TH ST	90013	14	129A211   281		[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM			PC Approved	03/24/2011 12:00:00 AM	ADDRESS	34.04707	-118.24889	TITLE 24 PLAN CHECK ONLY.  TENANT IMPROVEMENT,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16394	19041-20000-38169	1395 N VINE ST	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	03/17/2020 12:00:00 AM		Issued	03/17/2020 12:00:00 AM				Plan check for power and energy for first time tenant for an office of  Building D. Total area: 2500 sq ftB#19016-10000-28214	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16395	17041-20000-35980	5812-5822 W SANTA MONICA BLVD	90038	13	144B189  1082		C2-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.09057	-118.31621	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan hceck for energy only, indoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16396	17041-10000-15351	1439 W HILL DR	90041	14	165A227   189	5691023021	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	07/22/2017 12:00:00 AM	ADDRESS	34.1446	-118.19666	PC for roof mounted pv system.System size 3.8kwAC solar edge inverter, and 16 optimizers/ 16 panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16397	18041-10000-10943	22600 W VENTURA BLVD	91364	3	171B097   259	2040032035	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.16716	-118.61881	PLAN CHECK FOR TITLE 24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16398	11041-20000-06987	8722 W 3RD ST	90048	5	138B169   569	4334011056	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			PC Info Complete	04/07/2011 12:00:00 AM	ADDRESS	34.07344	-118.38225	ENERGY PLAN CHECK RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16399	18041-20000-38409	8250 N WOODMAN AVE 1st/2ndflr	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.22107	-118.43251	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16400	16041-10002-13740			3	186B109   378	2113004008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM			Corrections Issued	07/06/2016 12:00:00 AM	PIN	34.20721655	-118.58270614	CHANGES TO APPROVED SET  NOTE CHANGES TO DELTA 1 . CHANGES INCULDES MODULES LAYOUT PER FIELD INSTALLION.PV1, rooftop solar installation on SFD, 7.6kW AC.    (32) CS6X-270P       (1) SE7600A        P350 is used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16401	19041-10000-28274	12659 W MOORPARK ST	91604	2	165B161   264	2362015015	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.15051	-118.40938	PV2. NEW SOLAR SYSTEM ON AN EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.6KWdc / 11.2KWac.(42)MODULES-CSUN300-60M(42)MICROINVERTERS-IQ7PLUS-72-X-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16402	13041-10000-00461	2669 N GRIFFIN AVE 1-40	90031	1	139-5A223  23	5206005018	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			01/08/2013 12:00:00 AM			Reviewed by Supervisor	05/23/2014 12:00:00 AM	ADDRESS	34.07847	-118.21203	EXISTING APARTMENTS. REPLACE EXISTING SERVICE TO 600A, NEW 1000A DISTRIBUTION BOARD, AND SUB PANELS. ALL LOADS IN BUILDING ARE EXISTING TO REMAIN ***PHOTO VOLTAIC UNDER 12041-10001-01993*** Plan Checker please varify the EV load	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16403	13041-10000-26983	10110 W ROSSBURY PL	90064	5	123B165   469	4316017004	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Expired	10/23/2015 12:00:00 AM	ADDRESS	34.03443	-118.40458	PV1. ROOFMOUNTED SOLAR ARRAY. 2 STORY HOUSE. STANDARD MICROINVERTER PLAN.  ENPHASE 214 MICROINVERTER. SYSTEM SIZE: 4kW DC.(16) ALEO S-18 ULR S18U250  MODULES(16) ENPHASE M215-60-2LL-S22 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16404	18041-10000-29823	10923 W PICO BLVD	90064	5	126B157  1014	4322004040	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM			PC Info Complete	11/07/2018 12:00:00 AM	ADDRESS	34.03946	-118.43027	ENERGY PLAN CHECK FOR A CHANGE OF USE FROM OFFICE TO RESTAURANT AND MERGE WITH EXISTING RESTAURANT. SCOPE INCLUDES NEW LIGHTING AND  EQUIPMENT WITH A TOTAL AREA OF 2,705 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16405	17041-10000-37870	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	PIN	33.93847109	-118.41935625	PC FOR NEW MV 5KV 1200A SWITCH GEAR IN LAX.NEW SWITCHGEAR TO BE INSTALLED ON A RAISED PLATFORM. B#17010-10000-03677	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16406	13041-10003-22485	11040 W PICO BLVD	90064	5	126B153  1136	4256008014	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM			PC Approved	01/08/2015 12:00:00 AM	ADDRESS	34.03753	-118.43352	Change to approve set (13041-10002-22485) by adding circuit and relocating fixtures; all changes are under Delta-D only.(((([[[10/7/14 CHANGES TO APPROVED SET. DELTA  A CHANGES ONLY. PERMIT HAS BEEN PULLED UNDER 13041-10001-22485, ORIGINAL HAS BEEN INCLUDED]]]]][][CHANGES MADE TO FIRST SUBMITTAL PLANS; CHANGES IS TO COVER THE FOLLOWING: 1)TITLE-24, 2) DELTA-A and DELTA C CHANGES TO THE MASTER PLAN, ][][][PC FOR POWER AND ENERGY. TI TO (E) RETAIL.  99c STORE FULL TENANT IMPROVEMENT. 1000A service. previously a furniture store. not a methane zone. WITH PARKING LOT RE-STRIPING.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16407	18041-10001-18947	777 S SANTA FE AVE 1ST-FLOOR	90021	14	124-5A217 361	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	SUPPLEMENTAL CHANGES TO APPROVED SET CHANGES APPLY TO DELTA 1 ONLY. SCOPE  INCLUDES  ADDING NEW LIGHTING AND EQUIPENTS TO  AUDIO ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16408	17041-10000-24366	8211 N REMMET AVE	91304	3	189B105    35	2110019022	[Q]CM-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.21802	-118.60044	PC FOR COMMMERCIA PV SYSTEM USING 14KW INVERTER AND 32 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16409	19041-10000-09652	28122 S WESTERN AVE	90732	15	024B193   622	7442030207	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	Yes	2951.03	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	33.76387	-118.31024	PLAN CHECK FOR TITLE 24 ONLY CHANGE OF USE FROM RETAIL TO CHIROPRATIC OFFICE.TOTAL EFFECTED AREA 1362	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16410	17041-20000-40251	9617 W VENICE BLVD	90232	5	120B165   808	4313016018	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.02494	-118.39652	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM KARATE STUDIO TO DANCE STUDIO. 1190 SQFTBUILDING PERMIT # 17016-10000-10970	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16411	12041-20000-01224	1807 S BEVERLY GLEN BLVD 1-12	90025	5	132B157   730	4317001042	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			01/18/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.05666	-118.42393	Photovoltaic system on roof of apartment building.  13.2 kw, 60 modules and 2 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16412	20041-10000-06863	6390 W DE LONGPRE AVE	90028	13	147A187   290	5546016002	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			02/12/2019 12:00:00 AM			PC Approved	03/27/2019 12:00:00 AM	ADDRESS	34.09602	-118.32852	PC FOR POWER AND ENERGY FOR A 20 STORY TRANSIENT OCCUPANCY RESIDENTIAL STRUCTURE HIGHRISE BUILDING. 193 APPARTMENTS. SCOPE INCLUDES NEW (4000A) DISTRIBUTION EQUIPMENT CONNECTED TO EXISTING 4000A SERVICE PERMITED UNDER (17041-10001-24720 REFERENCE ONLY), PANELS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA IS 82333 SQ.FT - UNIT PANELS ARE SERIES RATED WITH ASSOCIATED FEED ONLY ALL OTHER EQUIPMENT IS FULLY RATED. B# 16010-10000-05333podium and basement parking under separate permit (15010-10000-04706).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16413	14041-10000-34841	13785 W RAYEN ST	91331	6	198B153   941	2640001015	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.23552	-118.4337	PV1 roof mounted. System size: 5 kW with (21) modules(kyocera #kd255gx-lfb3) and (1) inverter (solaredge #se5000a-us-zb-u)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16414	15041-20001-18687	6344 N TOPANGA CANYON BLVD A-2020	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	[ 4/28/16 changes to approved set. PLANCHECK ONLY. Addition of occupancy sensor and controlled receptactes in the recption area.  Remove fixture C (chandeliers) and replace it with fixture B]Plan check for power and Title-24 (energy).  Total area = 3,248 sq. ft.  T.I. to commercial first time tenant (Smirnoff Dance Studio).  New lighting and recepticles.  Counter plan check per E.M.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16415	17041-20000-14718	3169 N LAKE HOLLYWOOD DR	90068	4	159B181   390	5579027012	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	PIN	34.13173512	-118.34236811	PV1.  Install 3.05 kW roof mounted grid tied PV system.  (10) modules with (1) 3 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16416	12041-20000-19769	7561 N LANKERSHIM BLVD 201-203	91605	6	186B169   277	2317009010	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	34.20803	-118.38813	Electrical and energy plan check for first occupants of new tenant spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16417	18041-10000-08237	1271 W 39TH PL	90037	8	117B197   914	5037007019	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			03/07/2018 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.01423	-118.29941	NEW 3-STORY 8-UNIT APARTMENT. 600AMP 120/240V 1PH 3W SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16418	14041-20001-20954	3500 W WILSHIRE BLVD	90010	10	132B193   108	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.06157	-118.30077	Plans were lost. Permit will be pulled under supplemental. ((PC FOR POWER ONLY. NEW SERVICE AND DISTRIBUTION FOR FUTURE 2 STORY MINI MALL. EXISTING BUILDING WITH NEW ELECTRICAL CORE AND SHELL. PER BUILDING SUBMITTAL, PLAN CHECK FOR BUILDING EFFICIENCY BASED ON 2008 STANDARDS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16419	11041-20000-25148	10 UNIVERSAL 29TH FLR.	0										Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM			PC Approved	11/23/2011 12:00:00 AM				Conference room t.i.Energy, emergencyFire/ life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16420	16041-10001-45356	2643 E 25TH ST BLDG 7	90058	14	117A219   115	5168022006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.01546	-118.22426	PC FOR CHANGES TO APPROVED SET OF PLANS. ADDITION OF SOME MOTORS AND CIRCUITS AND ADDITION OF FLOOR PLAN FOR OUTLET LOCATIONS. PERMIT TO BE ISSUED FOR ADDITIONAL CIRCUITS. RECONFIGURE MCC LINE UPS AND NEW CIRCUIT DESIGNATIONS. ALL CHANGES UNDER DELTA_3 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16421	17041-20000-18550	21004 W BALTAR ST	91304	3	189B109   263	2109009023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.21662	-118.59082	pv1install roof mounted pv system sized 11.3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16422	15041-10000-28440	4700 W SUNSET BLVD 5TH-6TH FLR	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.09788	-118.29194	PC FOR ENERGY ONLY, T24 TO KAISER MEDICAL CENTER. REMODEL OF THE 5TH FLOOR AND 6TH FLOOR RECEPTION  AND WORK AREAS ONLY. NEW LIGHTING ON THE 6TH FLOOR. TOTAL SQ FT. 737	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16423	11041-10001-26376	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	33.98645	-118.44148	DELTA 4 CHANGES TO THE APPROVED PLANS. NEW CIRCUITS, LOADS & T-24.PLAN CHECK POWER AND ENERGY FOR RELOCATION OF 800A SWITCHBOARD, ESCALATORS, AND OUTDOOR LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16424	17041-20000-17044	6998 N SALE AVE	91307	12	183B101   870	2024025032	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.19753	-118.61718	Plan check for solar pv system, roof-mounted on SFD.4kW ungrounded system.(13) 330W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16425	19041-10001-21741	241 E CENTURY BLVD #2	90003	8	091-5A205  81	6052016024	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	ADDRESS	33.94575	-118.27027	CHANGES TO APPROVED PLANS, SCOPE OF WORK INCLUDES ADDING A SUBPANEL TO A PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16426	10041-20001-12568	6400 N TAMPA AVE	91335	3	180B117   788	2128031153	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.18677	-118.55325	Plan check revision to approved plans. Changes to lighting fixture and T-24 calculation. Permit to include new 400A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16427	16041-20000-18888	1545 N AMALFI DR	90272	11	132B133   114	4425021005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.05928	-118.50422	Plan check for New SFD 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16428	19041-20000-38648	2071 W RIDGEVIEW AVE	90041	14	159A223    41	5685018017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.13147	-118.21282	Plan check for PV roof mounted system, PV system size: 3.2KW with 8 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16429	18041-10000-03025	8500 W BEVERLY BLVD STE 105	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI TO FIRST TIME TENANT FOR A  RESTAURANT (2500 SQ) W/OUTDOOR DINING FOR POWER AND ENERGY (IN A CORE AND SHELL SPACE). SCOPE INCLUDES  NEW DISTRIBUTION PANEL, 112.5KVA TRANSFORMEREQUIPMENT PANELS AND CIRCUITS.TOTAL AFFECTED AREA 2564 SQ.FT  ( TO BE VERIFIED)  INDOORS AND OUTDOORS. PLAN CHECKER TO UPDATE PE OF RECORD.B# 18016-10000-01668	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16430	14041-10000-18682	4500 W WILSHIRE BLVD	90010	4	132B185    45	5090014001	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.06175	-118.32753	FO: PLAN CHECK FOR ENERGY ONLY. 2013 T24 CODE. BLDG#14016-10000-13655: tenant improvement (1st floor only ) to (e) office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16431	16041-10000-36438	1107 W 185TH ST	90248	15	060B197   122	6109021012	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Closed	09/20/2017 12:00:00 AM	ADDRESS	33.86282	-118.29303	low permit fee due to senate bill 1222 from 2012PV1 roof mounted solar system installation to a singe family home. Installing 41 microinverterts rated at 215 Watts each for a total system  size of 11.48kw ac	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16432	18041-20003-44200	2227 N OUTPOST DR	90068	4	153B181   319	5572008012	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	ADDRESS	34.11277	-118.34479	12-26-2018 Changes to an approved set of plan, changes include remove sub-panel. all changes has been clouded. Plan check only.  $0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16433	16041-20000-42990	22300 W MULHOLLAND DR	91364	3	165B101   186	2173001015	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.14916	-118.61059	Change out of fire alarm panel, like for like (same model/manufacturer).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16434	15041-10000-29969	4485 N HAZELTINE AVE	91423	4	168B153   867	2265022032	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Apartment			09/10/2015 12:00:00 AM			Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.15281	-118.44021	PC FOR ENERGY FOR PARKING LOT OF A 2-STORY, 5-UNIT APARTMENT BUILDING. TOTAL AREA 4660 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16435	16041-10000-17940	1000 W ELYSIAN PARK AVE LEVEL 5	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			Verifications in Progress	08/01/2016 12:00:00 AM	ADDRESS	34.07196	-118.24719	PC for  T-24 only. Installing new lighting on level 5 corridor and escalator of Dodger Stadium. Total area 4,505 sq.ft. New connected load less than 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16436	11041-10000-10880	777 S FIGUEROA ST 30th floor	90017	9	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	06/09/2011 12:00:00 AM	ADDRESS	34.04828	-118.26116	T.I.  Relocating light fixtures and installing one new light fixtures on the 30th floor of an office building.  Plan check was per inspector's request.  Title 24 plan check only with permit for the circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16437	13041-20001-33854	9261 N RUBIO AVE	91343	12	198B137   546	2687026020	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.23916	-118.49547	(((CHANGES MADE TO APPROVED SET OF PLANS. NUMBER OF MODULES AND NUMBER OF INVERTERS DID NOT CHANGE, ONLY CHANGE OF MODULE AND INVERTER MANUFACTURER. KW RATING OF INVERTERS ARE NOW 4.2KWAC EACH)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC. 36 MODULES AND 2 INVERTERS. LOW PERMIT FEES DUE TO 2012 SENATE BILL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16438	14041-10001-00641	161 N ISLAND AVE	90744	15	027B205   441	7440006911	PF-1D	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	33.77052	-118.2659	Expedited plan check per applicant request.  (((New LADWP Administrative Office (5,513 sf) and 2,160 sf maintenance building.  New 500A 480/277V service and distribution equipment.  Methane zone.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16439	18041-20000-17484	9466 N REMICK AVE	91331	7	198B161    80	2626016064	RA-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.24157	-118.41666	PV2.  Install 22.75 kW DC roof mounted grid tied PV system.  (70) modules regulated by power optimizers with (2) 14.4 kW AC rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16440	14041-20000-35559	11150 N CLAIRE AVE	91326	12	210B121   203	2718002001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.27308	-118.54739	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.8KW.(1) ABB 4.2 KW INVERTER(18) SOLARWORLD 270 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16441	19041-20000-00772	15821 W VENTURA BLVD 3r flr	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Issued	01/08/2019 12:00:00 AM	ADDRESS	34.15584	-118.47812	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16442	16041-10000-32478	13500 W PAXTON ST	91331	7	210B157   139	2535002012	M2-1-CUGU, M3-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM			Corrections Issued	12/20/2016 12:00:00 AM	ADDRESS	34.27449	-118.4247	PC FOR OUTDOOR T24 FOR LED RETROFIT OF EXISTING POLE MOUNTED LUMINAIRES. PROVIDED NEW LIGHITNG LAYOUT AND T24 DOCUMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16443	13041-10000-23621	3635 N SHERIDGE DR	91403	4	159B145   646	2279006010	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.13636	-118.46577	PV1.  Install 7.35 kW roof-mounted solar array, interconnect with main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16444	13041-10003-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	CHANGES TO APPROVED SET. DELTA 20, 20A,21and 21A.  CHANGES ARE CLOUDED. CHANGES TO SINGLE LINE AND LIGHTING LAYOUT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16445	16041-20000-40821	20255 W CORISCO ST	91311	12	198B113   202	2748001049	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/03/2016 12:00:00 AM	ADDRESS	34.23564	-118.5751	remove existing hid fixtures and replace with led.  plan check for indoor and outdoor energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16446	18041-20000-02130	3648 N AMESBURY ROAD	90027	4	154-5A203 301	5592009033	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.11626	-118.27862	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consists of (15) AC PV modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16447	18041-10002-35822	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	Phase 2 of a new 312,000 sqr ft warehouse. Installing additional motors and equipment to coveyor belt systems in the warehouse. Total added load > 400Amp. (Orig Plans for Phase 1 were checked by Francis)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16448	18041-10000-34508	1800 S AVENUE OF THE STARS GRND FLR	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.06095	-118.41786	Plan check for T24 only on an (E) commercial space, TI on bathrooms and elevator lobby. Total area: 950 sq.ft(B# 18016-10000-02488)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16449	17041-10000-05084	6255 W SUNSET BLVD #780	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.09815	-118.32564	T-24, PC FOR ENERGY ONLY. TI TO AN (E) OFFICE SPACE.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SUITE 780. TOTAL AFFECTED AREA IS 1336 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16450	18041-10000-38203	750 S LAMAR ST HOSTLER FU-EL AREA	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (A) THE HOSTLER FUELING AREA 1 OF 10BUILDING PERMIT # N/A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16451	11041-10000-04479	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	33.95887	-118.41869	INSTALLATION OF EMERGENCY GENERATOR; FIRE PUMP AND FIRE PUMP CONTROLLER WITH ASSOCIATED TRANSFER SWITCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16452	19041-10000-48429	555 W 5TH ST 19TH FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR T-24 ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16453	11041-20000-12376	6310 W SAN VICENTE BLVD 1ST FLR	90048	5	132B173   193	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			Reviewed by Supervisor	07/26/2011 12:00:00 AM	ADDRESS	34.06084	-118.36757	PLAN CHECK POWER AND ENERGY MEDICAL OFFICE ON FIRST FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16454	13041-10000-32218	621 S WESTERN AVE 201-202	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.0628	-118.30928	plan check and permit EXPAND DENTAL OFFICE BY JOINING UNIT #201,202#201 IS AN EXISTING DENTAL OFFICE.#202 IS A RETAIL SPACE. CHANGE OF USE TO DENTAL OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16455	10041-20000-07253	535 W 41ST ST	90037	9	115-5A201 178	5019023028	RD1.5-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Public Safety Only			04/20/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.00977	-118.28361	Plan check for new installation on fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16456	13041-10000-07246	21504 W VICTORY BLVD	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.18786	-118.59909	T24 FOR A STARBUCKS TI.  NEW LIGHTING IS GREATER THAN 50% OF THE EXISTING LIGHTING.  1450 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16457	18041-20000-46713	8046 N WILBUR AVE	91335	12	189B121   147	2103011003	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.217	-118.54462	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16458	15041-20000-39773	1529 W 35TH ST	90018	8	120B193   825	5041001042	RD2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Expired	12/28/2017 12:00:00 AM	ADDRESS	34.02473	-118.30398	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.5KWac. (10)MODULES-BOVIET 260W(1)INVERTERS-FRONIUS GALVO 2.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16459	12041-20000-00283	3700 N COLDWATER CANYON AVE Pool-building	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.13809	-118.41286	T-24 lighting plan check for interior and exterior lighting for new two level pool building with mechanical room on lower level and offices, meeting, restrooms, etc. on the upper level.  Pool lights are exempt from installed lighting requirements of T-24 but, not from controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16460	19041-10000-18129	14428 W HAMLIN ST	91401	6	180B149   628	2237023005	[Q]C1-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.18847	-118.44754	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16461	16041-20000-21613	14412-14414 W VENTURA BLVD	91423	4	166-5A151 178	2266001015	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Refund in Progress	09/22/2016 12:00:00 AM	ADDRESS	34.15037	-118.44642	"T.I. to convert (E)39'-10"" x 75' bank into two retail shell spaces.   Plan check for energy.Building permit under 16016-20000-06010"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16462	16041-20000-31255	3254 N LOWRY ROAD	90027	4	153A203   338	5434004019	R1-1	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.11199	-118.27936	Plan check for a PV1 roof-mounted PV system. System size is 12.8 kWac and consists of (39) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16463	12041-10000-20196	13640 W FOOTHILL BLVD	91342	7	222B157    94	2509014014	(T)(Q)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.3076	-118.43089	Plan check fire alarm system for 3 story commercial building. Permit for new fire alarm system and new branch circuit to supply fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16464	19041-30000-00845	2029 S CENTURY PARK EAST Concourse	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is a tenant space in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 314 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16465	16041-20000-18384	17948 W RAYMER ST	91325	12	195B129   549	2787035049	R1-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	05/28/2016 12:00:00 AM	ADDRESS	34.22715	-118.52465	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.8 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16466	11041-20000-21207	319 S ROBERTSON BLVD	90048	5	138B169   621	4334011047	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM			Corrections Issued	10/04/2011 12:00:00 AM	ADDRESS	34.07296	-118.38391	T.I  Existing retail store.  Remodel of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16467	12041-10000-08923	5717 S HOOVER ST	90037	9	108B197  1295	5001014030	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	33.99007	-118.28725	PLAN CHECK POWER AND ENERGY FOR ADDITION OF MEDICAL OFFICE BUILDING. NEW 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16468	18041-20001-00840	19130 W CHARLES ST	91356	3	168B121   226	2176031008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.15733	-118.55007	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp with battery back up.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16469	17041-10000-26749	5855 W CENTURY BLVD	90045	11	090B169    11	4125025039	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	33.94572	-118.38488	PC for T24 for TI in bar area on level 2. Installing new branch cirucits. Total affected area of 1809 sqft . Building# 17016-10000-21412.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16470	11041-10000-20652	1025 E ELKGROVE AVE BLDG 40	90291	11	111B145   625	4243003039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.00092	-118.45924	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16471	12041-10000-18789	3350 W VERNON AVE	90043	8	111B185   127	5013023012	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Info Complete	08/09/2012 12:00:00 AM	PIN	34.00336602	-118.33135602	TI IN AN EXISTING EL POLLO LOCO. PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16472	15041-10000-25654	807 N HUDSON AVE 1-34	90038	4	141B185   235	5533025005	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			08/07/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.08556	-118.33232	PC FOR POWER AND ENERGY. NEW 4 STORY, 34 UNIT APARTMENT BUILDING. TOTAL AREA 30000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16473	14041-10000-17505	3900 N STANSBURY AVE	91423	4	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.14084	-118.44264	NEW TWO STORY WITH BASEMENT AND MEZZANINE, TYPE II B EDUCATIONAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16474	15041-20001-14266	20519 W LONDELIUS ST	91306	3	195B109   230	2780013008	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.22919	-118.58041	Expedite per applicant request*******Plan check for PV roof mounted system 12.0kWac system with 58 modules and 2 inverters(6.0kW) and 4 strings	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16475	15041-10000-07832	10520 W CROCKETT ST	91352	2	192B177   810	2407004008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Expired	05/04/2017 12:00:00 AM	ADDRESS	34.22002	-118.36029	PV1 INSTALL 6.63 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE, TIE WITH MAIN SERVICE PANEL. (26) MODULES: KYOCERA KD255GX. (1) INVERTER: SOLAREDGE SSE6000A-US-ZB-U.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16476	19041-20000-31751	4874 W AMBROSE AVE	90027	4	150B197   332	5589019018	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Expired	05/20/2024 12:00:00 AM	ADDRESS	34.10892	-118.29585	PV1. INSTALL (39) ROOFMOUNTED MODULES WITH POWER OPTIMIZERS AND (3) WALL MOUNTED TESLA ENERGY STORAGE SYSTEMS. SYSTEM SIZE 12.28 KW DC.$0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16477	18041-20000-03090	1331 N CAHUENGA BLVD	90028	13	147A187   342	5546017007	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Closed	03/26/2021 12:00:00 AM	ADDRESS	34.09556	-118.32924	temp power for new construction site.  1000 amp service.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16478	19041-20000-11091	654 N VIRGIL AVE	90004	13	142-5A201 290	5539026035	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Issued	04/10/2019 12:00:00 AM	ADDRESS	34.08334	-118.28667	Plan check for a PV2 roof-mounted PV system. System size is 24.05 kWdc/20.68 kWac-CEC and consists of (2) inverters, (65) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16479	11041-10002-24606	1500 S OLIVE ST	90015	14	124-5A207 184	5134023009	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM			PC Info Complete	05/25/2012 12:00:00 AM	ADDRESS	34.03567	-118.26482	DELTA 5 REVISION TO APPROVED PLANS. PLAN CHECK NEW PANEL 2LD FOR NEW X-RAY EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16480	17041-10000-41382	134 1/2 E GAGE AVE	90003	9	105B205   941	6006014024	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Issued	11/15/2017 12:00:00 AM	ADDRESS	33.98229	-118.27255	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 6.0KWAC  7.4 KWDC SCOPE INCLUD 20 MODULES WITH OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16481	15041-10000-08539	3523 S CENTINELA AVE	90066	11	114B153   477	4246006001	[Q]C1-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.00999	-118.43857	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING (RESTAURANT).  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1660.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16482	18041-20000-28322	3521 W WASHINGTON BLVD	90018	10	126B189   822	5072021014	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.20	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM			PC Info Complete	09/20/2018 12:00:00 AM	ADDRESS	34.04006	-118.32323	Change of use from printing establishment to 17 commissary kitchens spaces.  1200A 208Y/120V 3-phase 4-wire service.Building permit under 18016-10000-18048.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16483	17041-10000-09270	18505 W DEVONSHIRE ST	91324	12	204B125   100	2728028025	C2-1, C2-1VL, P-1VL, PB-1, RE15-1-H	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.25745	-118.53702	Plan check for power and energy for new restaurant Chick-Fil-A 1200A Service 1 story. Total area: 5,279 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16484	14041-10000-24451	2740 W WAWONA PL	90065	14	160-5A219 168	5683020014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.13401	-118.22473	PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(24) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16485	16041-10000-39764	12300 W WILSHIRE BLVD STE-404	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.04245	-118.46922	Full plan check for a dental office T.I  in an existing commercial building.  Total area = 1,070 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16486	19041-10000-47187	11200 W SHERMAN WAY	91352	2	183B173   114	2319022007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	07/09/2023 12:00:00 AM	ADDRESS	34.20103	-118.37534	per ab # 1414 fees are $0.00PC FOR ROOF TOP PV2 FOR A FEED IN TARIFF INSTALLATION. SYSTEM SIZE IS 266.4 KWdc (200 KWac & 240.1 KWcec-ac) USING (666) LG400N2T-J5 MODULES, (342) SE P860 OPTIMIZERS AND (2) SE100K-US CENTRAL INVERTERS. CONNECTED TO AN (E) 400 AMP PV PANEL BOARD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16487	12041-20000-10857	5600 N VAN NUYS BLVD	91401	2	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.17244	-118.44837	Addition of external lights to existing building. Plan check for energy. 1590 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16488	11041-20000-04725	13079 W CHANDLER BLVD	91401	5	171B161    87	2345012007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.16873	-118.41784	PLAN CHECK WAS SERVICE ONLY<<<<<<<chabad of north hollywood power only future lighting>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16489	13041-20000-34738	2964 N PARK CENTER DR	90068	4	157-5A183 226	2429025012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.12411	-118.3449	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 5.184KWAC. 24 MODULES AND MICROINVERTERS. 200A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16490	12041-20001-27943	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.03497	-118.45709	Changes to approved set of plans. Change from 50A breakers to 40A breakers for all car chargers and #6 to #8 conductors for all car chargers.CUSTOMER BROUGHT CHECK. PLEASE RECALCULATE FEES BEFORE FINAL APPROVAL. NEW SERVICE? separate fire alarm variance filed 6/17/2013 mtNEW PARKING GARAGE. FULL POWER AND ENERGY PLAN CHECK. new parking facility. 833 car. 5 and half tier.  68621 sf below and 187934 sf above grade. 981 sf of attached restrooms and lockers. total SF = 257536 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16491	17041-20000-00458	11739 W VICTORY BLVD	91606	2	180B169  1136	2322016048	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.18684	-118.38919	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from a vet clinic to office/tenant improvement. Total lighting area = 1,389 sq. ft.Note: Building permit has been pulled under 16016-20000-23730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16492	19041-10000-42253	12305 W TERRA BELLA ST	91331	7	210B165   383	2532015010	A2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	03/28/2023 12:00:00 AM		Issued	03/28/2023 12:00:00 AM	ADDRESS	34.27136	-118.4007	FULL PC FOR POWER AND ENERGY. (NEW 1-STORY CHURCH). SCOPE INCLUDES NEW 1200A 120/208 3 PHASE 4 WIRE SERVICE. TOTAL AFFECTED AREA IS 145,635 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16493	14041-10000-15395	1301 N CATALINA ST	90027	13	147B197  1068	5543019009	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			Corrections Issued	06/10/2014 12:00:00 AM	ADDRESS	34.09569	-118.29526	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. OFFICES. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS.  2859 SQFT, EMERGENCY LIGHTING. 2ND FLOOR TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16494	18041-10000-22953	309 E 8TH ST	90014	14	126A211    30	5145003009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.04121	-118.25128	PC FOR BEAUTY SALON REMODEL FOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 4309 SQ.FT B# 18016-10000-11286	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16495	15041-20001-39987	1627 S PANDORA AVE	90024	5	132B157   454	4326030026	R1-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.05883	-118.42617	Expedited per customer request.PV1. Install roof mounted PV system sized 5 kW. Interconnectd with main service panel.(19) SunEdison 325W Modules(19) SolarEdge Power Optimizers(1) Solar Edge SE5000A Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16496	11041-10000-18443	21021 W VENTURA BLVD	91367	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			PC Approved	08/30/2011 12:00:00 AM	PIN	34.16705846	-118.59120236	T.I.  Remodel of the bathroom light fixtures on the second floor of the building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16497	13041-10000-01852	656 S MAIN ST	90014	14	127-5A211 120	5148021012	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.044	-118.25101	existing restaurant. T24 ONLY FOR MEZZANINE AND 1ST FLOOR LIGHTING. SCOPE OF WORK IS REMODOLING OF LIGHTING FIXTURES. TOTAL AREA OF 1726 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16498	15041-20000-35236	20443 W ACRE ST	91306	3	195B109   158	2781036015	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Expired	11/21/2017 12:00:00 AM	ADDRESS	34.23002	-118.57902	PV1,  roof mounted solar 8.215 kW.(31) modules: #KU2656ZPA(1) Inverter PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16499	19041-20000-20664	7843 W 79TH ST	90293	11	099B153   146	4114006028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	33.9633	-118.43466	Plan check for PV roof mounted system, PV system size: 12.2KW DC, 10.0KW AC with 27 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16500	19041-10000-43191	134 S DENSLOW AVE	90049	5	138B149   148	4366023005	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.07366	-118.45826	Power plan check for replacing (1) panel,  (1) battery system, and adding (1) new panel to an existing PV roofmounted system.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16501	16041-10000-41897	720 S RAMPART BLVD	90057	1	133-5A201 247	5141013801	C2-2	Central	Westlake			2094.01	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM			PC Info Complete	02/07/2017 12:00:00 AM	ADDRESS	34.05875	-118.28344	PC FOR POWER ONLY. SCOPE INCLUDES ADDING A NEW 1200A 480V 3PHASE 4 WIRE DISTRIBUTION BOARD FOR A NEW TEMPORARY CHILLER, AND NEW PUMPS, SCOPE ALSO INCLUDES REPLACEMENT OF EXISTING CHILLER, PUMPS AND ASSOCIATED EQUIPMENT. B#16016-10000-28126	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16502	19041-20000-22171	22135 W ROSCOE BLVD LOT #13	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 13.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16503	19041-20000-51931	13430 W RELIANCE ST	91331	6	195B157  1119	2627006010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	34.22759	-118.42547	PV1. INSTALL 7.36 KW DC ROOFMOUNTED PV SYSTEM WITH (23) MODULES, OPTIMIZERS AND (1) INVERTER(SE7600)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16504	11041-20000-26885	15624 W ROYAL RIDGE ROAD	91403	5	162B141   354	2280008019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2011 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	ADDRESS	34.13817	-118.47382	Photovoltaic system installed on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16505	15041-20004-32712	13202 W CHANDLER BLVD	91401	4	171B157   126	2345022020	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.16825	-118.42036	12/23/15Changes to an approved set. Changes include going from a 200A non fused AC disconnect to a 200A fused AC disconnect. permit pulled under PCIS#15041-20000-32712 (((Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (70) modules, (1) combiner box, and (1) load center.Note: $0.00 permit fees due to Senate 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16506	13041-10000-26820	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			10/15/2013 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	33.97574	-118.39042	New 218-unit apartment building at Howard Hughes Center.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16507	15041-10001-35360	7051 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	33.94265	-118.41882	2/19/2016CHANGES TO AN APPROVES SET OF PLANS, CHANGES INCLUDE THE DETAILS OF GROUNDING METHODS, ADDITION OF METHANE PULL SECTION TO SWITHGEAR 'A' AND THE CONFIGURATION OF PANEL LP4.  (((PC for power, Temporary medium voltage, 4.16KV, from LAWA power trailor #1 to feed Switchgear A and Panel LP4. Switchgear A has three feeders feeding  A-1, A-2 and A-3.  A-1 and A-2 have existing loads and A-3 is for future construction load. Panel LP4 is for power shelter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16508	13041-10000-23508	23752 W LADRILLO ST	91367	3	171B093   523	2047004016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM			No Progress	12/18/2013 12:00:00 AM	ADDRESS	34.16417	-118.64296	PV1 - INSTALL ROOF MOUNTED PHOTOVOLTAIC SYSTEM  INTERCONNECT WITH MAIN PANEL. DERATED MAIN. SYSTEM SIZE: 13.72KW  UNGROUNDED AURORA INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16509	14041-20000-26807	11133 W VANOWEN ST	91605	2	183B173   182	2319005017	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.19409	-118.37363	CHANGES TO APPROVED SET OF PLANS. CHANGE IN LIGHTING. NO CHANGE IN FLOOR AREA. T24 ENERGY ONLY. CHANGES CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16510	19041-20000-53519	4153 N NAGLE AVE	91423	4	165B157  1020	2373003007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.14542	-118.4238	PV1.  INSTALL 14.52 KW DC ROOFMOUNTED PV SYSTEM AND 13.5 KWH ENERGY STORAGE SYSTEM.  (44) MODULES WITH MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16511	13041-20000-12747	555 S FLOWER ST FLr 18	90071	9	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for energy and emergency lighting. 18th floor, conference room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16512	15041-10000-27859	9600 N LURLINE AVE	91311	12	201B109   290	2748040027	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.24455	-118.58404	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.PV2. installation of a roof mounted solar system for a commercial site. (2) inverters: 58.04 KW, (108) solar modules. (1) load center of 100 A. Line side tap.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16513	16041-10000-11267	11300 W OLYMPIC BLVD	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Expired	05/02/2018 12:00:00 AM	ADDRESS	34.03792	-118.44134	PC FOR ENERFGY. T.I FOR OFFICE. TOTAL ARAEA 1109 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16514	15041-20000-32084	135 S BEACHWOOD DR	90004	4	138B189  1014	5515023017	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.0726	-118.32252	PV1Install a roof mounted solar array on a SFD. Interconnect with a 400A split bus panel (derating 200A main to 175A).System size: 7.2kW (3+4.2). (24) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16515	15041-10000-42621	4690 W COLORADO BLVD	90039	13	162B201    75	5593018013	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM			Reviewed by Supervisor	01/13/2016 12:00:00 AM	ADDRESS	34.14012	-118.27542	INSTALLING FEEDERS FROM AN INSIDE BUILDING SWBD ALONG WALL UP TO ABOVE ROOF TO A NEW 1200A DISTRIBUTION BOARD MOUNTED ON THE ROOF AND EXISING LOAD FEEDERS WILL CONNECT TO THIS ROOF-SWBD THROUGH THE OLD SBD  USED AS J-BOX  AND ANOTHER J-BOX MOUNTED BELOW THE ROOF DIRECTLY BELOW THE NEW SWBD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16516	14041-10000-23839	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICIES. CHANGING FROM COMMERICAL TENANTS TO OFFICES.. NEWLY CONNECTED LOAD < 400 AMPS. 3955 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16517	13041-10000-31873	11550 W VENTURA BLVD 1-10	91604	2	162B169   593	2369035036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.13977	-118.38378	Remove HID light fixtures and replace with new fluorescent fixtures in auto repair garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16518	19041-20000-16308	14101 W PIERCE ST	91331	6	201B153   465	2644005032	RS-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	07/27/2019 12:00:00 AM	ADDRESS	34.24748	-118.44057	Plan check for battery back up system Tesla PowerWall 2.0, Battery system size: 13.5KWh installed into existing PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16519	11041-10000-18089	1640 S SEPULVEDA BLVD SUITE #450	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM			PC Approved	08/25/2011 12:00:00 AM	ADDRESS	34.04838	-118.44468	TI TO AN EXISTING OFFICE SPACE, SUITE #450.  PLAN CHECK IS FOR ENERGY ONLY.  PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16520	14041-10000-17286	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.0484	-118.26248	PC FOR POWER AND ENERGY. TOTAL AREA 20,265 SQ FT. OFFICE TI  CORE/SHELL. Fees based on supplemental 10001's panel schedule.BUILDING APPLICATION# 14016-10000-12538	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16521	12041-20000-30719	14708 W VENTURA BLVD	91403	5	166-5A149  67	2276002020	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.15154	-118.45347	Replacement Fire Alarm System for an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16522	10041-20000-14735	2466 S CORINTH AVE	90064	11	123B153   449	4260040023	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			07/29/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	34.03318	-118.43822	Plan check for new 8-unit apartment building. Modification to seperate fire alarm system plan has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16523	16041-10000-42994	8327 W 3RD ST	0	5									Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM				Energy plan check for a retail T.I. Scope includes new lighting and equipment. Total area is 2666 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16524	18041-20000-00407	13442 W CORCORAN ST	91340	7	213B157   257	2524019009	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.282	-118.42542	34$ permit fees due to senate bill 1222Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consits of (2) inverters, (38) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16525	17041-20002-35358	2209 S SANTA FE AVE	90058	14	118-5A217 206	5167008028	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.01795	-118.23056	Revisions to approved set.  Addition of PV meter.  Change of inverter output circuit wiring detail.  Revised equipment AIC ratings.  (((PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 115 KW (320) NEO SOLAR POWER 360(3) SOLAR EDGE SE33.3KUS(160) P800 OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16526	17041-20000-37641	2239 W WASHINGTON BLVD	90018	10	126B193   909	5073014015	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM			PC Info Complete	05/14/2018 12:00:00 AM	ADDRESS	34.04009	-118.31038	Plan check for power and energy. Core & shell for new three story (w/ basement) office building. 800A 120/208V 3ph 4w service.  All work in/for tenant spaces is future (including unit panels), sheets included for reference only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16527	17041-20001-37887	13350 N GLADSTONE AVE	91342	7	225B157   369	2510001020	(T)RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			Reviewed by Supervisor	11/01/2017 12:00:00 AM	ADDRESS	34.31419	-118.43228	expeditepv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16528	19041-20000-46999	20422 W VIA BOTTICELLI	91326	12	219B109   225	2701059007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.29849	-118.57912	Plan check for PV roof mounted system, PV system size: 10.385KW with 31 PV Modules and 31 microinverters, connected to existing 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16529	15041-10001-18140	1063 S WOOSTER ST	90035	5	132B169   422	4332016034	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			08/02/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.05743	-118.38271	PC FOR RESTAMP PLANS RTI. ORIGINAL SET OF PLANS LOST. PERMIT TO BE ISSUED UNDER MASTER. RESTAMP THIS SET AS MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16530	16041-20000-06590	14235 W VENTURA BLVD	91423	4	165B153   335	2265019007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.15022	-118.44335	Plan check for power only. Project site is an existing commercial building. Project scope is a new 600-amp service and distribution board. All loads are future and are not under this scope of work.Note: Building permit has been issued under 15016-20000-10626	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16531	14041-20000-31798	6737 N TAMPA AVE	91335	3	180B117    51	2131001004	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.1929	-118.55377	PV1Install a roof-mounted solar array on SFD and detached garage. Interconnect with 200A MSP.System size: 6kW. Ungrounded system.20 327W pv modules across 4 strings (5+5+6+4).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16532	14041-20000-01619	12037 W HART ST	91605	2	183B165   234	2321008025	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Apartment			01/21/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.19768	-118.39551	NEW FIRE ALARM SYSTEM. 1 FIREALARM PANEL AND 104 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16533	16041-20000-45845	880 N STONE CANYON ROAD	90077	5	144B149   255	4370022025	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM			Plans on Hold	01/10/2017 12:00:00 AM	ADDRESS	34.08988	-118.44679	Plan check for power only. New accessory living quarter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16534	16041-10000-29461	922 E E ST	90744	15	030B209   812	7424017043	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	33.77595	-118.25106	NEW SERVICE UGRADE. EXISTING 3 SERVICES((2)800A & (1)1600A) FEEDING COMMERCIAL BUILDINGS(1 OWNER/LOT) TO NEW 5000A SERVICE UPGRADE FEEDING EXISTING SWITCHBOARDS RATED AT 800A & 1600A (480/277V) AND 800A(120/208).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16535	14041-10000-12643	959 N SEWARD ST EAST BLDG	90038	4	144B185   969	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.08878	-118.33338	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. 201 DEVICES AND 1 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16536	16041-20000-36686	7560-7562 W MELROSE AVE	90046	5	141B177   652	5526016002	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Issued	01/17/2017 12:00:00 AM	ADDRESS	34.08353	-118.35473	Retail tenant improvement in (E) commercial single-story building - 3,743 square feet.  New 400 A service.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16537	18041-10000-32306	1920 S GRIFFITH AVE	90011	9	121-5A211 389	5131008055	QM1-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Issued	08/24/2018 12:00:00 AM	ADDRESS	34.02531	-118.25385	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16538	13041-10000-04399	538 N VISTA ST	90036	5	141B181   983	5526024022	R1-1-O	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.08135	-118.3521	PV1 single story home. Total system size: 2.695KW. [Solar Module: Bosch Solar Module c-Si M 60. Model#: NA30117] [Inverter: Aurora Power One. Model#: PV1-3.0-OUTD-S-US].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16539	12041-20000-25760	10250 W SANTA MONICA BLVD FC-7	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	New lighting for pizza restaurant in mall.  T-24 lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16540	18041-10000-13596	4544 W MELBOURNE AVE	90027	4	150B197  1173	5590022003	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Expired	05/01/2024 12:00:00 AM	ADDRESS	34.10348	-118.28904	NEW ROOFTOP SOLAR SYSTEM ON TWO INTERCONNECTED SINGLE FAMILY DWELLING UINITS ( 1 AND 1/2). (1 OF 2) CONSIST OF  23 MODULES ( EAGLE MP 60B- 285W), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS 320) WITH A CENTRAL INVERTER (SOLAR EDGE SE 5000H-US).  SYSTEM SIZE IS  6.6 KWdc AND 5 KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16541	12041-10000-14223	3801 N BARHAM BLVD	90068	4	162B181    19	5581003***	(Q)C1-1L, RE20-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/28/2012 12:00:00 AM	ADDRESS	34.14381	-118.34135	T.I. to an existing office building at NBC-Universal (100 Universal Ciity Plaza Building 9128-03.    Change to lighting and circuits.  Load is less than 400A per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16542	17041-10001-13666	3643 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.02019	-118.3559	Title 24 plan check.  T.I . to divide existing retail space into two new retail spaces with new handicap restrooms.  Subpanels to remain existing with new lighting and receptacles.  Total area = 1,877 sq. ft.     Building permit #16016-30000-24375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16543	19041-20000-53564	1625 W PALO ALTO ST	90026	13	136-5A207  74	5159023020	(T)(Q)R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	2084.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			PC Info Complete	04/09/2024 12:00:00 AM	ADDRESS	34.06941	-118.26208	Full Plan check for new commercial building. New 3000A 120/208V 3P 4W Service, distribution equipment, lighting, and power loads. Total area: 62643 sq ft. Building permit under 19010-20000-06115	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16544	14041-20000-18126	20236 W GRESHAM ST	91306	3	195B113   248	2781034028	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.23066	-118.57466	PV1Install roof-mounted solar array on SFD. System size: 3.12kW(13) Enphase M250-60-2LL-S2X-IG micro inverters(13) Sun Edison F270W pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16545	17041-20000-24251	950 S CARMELINA AVE	90049	11	126B141    93	4264021020	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.04453	-118.47376	pv1install roof mounted pv system sized 3kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16546	16041-10000-16422	10300 S GLASGOW PL	90045	11	090B173   236	4129031002	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	33.94296	-118.37069	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM OFFICE TO BODY SHOP; SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND NEW PANELS. TOTAL AFFECTED AREA IS 9824 SQ. NON HAZARDOUS LOCATION PER BUILDING. BUILDING PERMIT# 16016-10000-10633.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16547	19041-20001-15322	6320 N CANOGA AVE Ste 1300	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.18499	-118.59722	Revisions to approved set.  Changes to luminaire schedule.  Lighting added to elevator lobby. Miscellaneous power changes not subject to review.(((TI to (E) commercial office space in highrise building.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16548	17041-10000-13515	19724 W NORDHOFF PL	91311	12	195B117     3	2761001034	(T)P-1, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Issued	10/12/2017 12:00:00 AM	ADDRESS	34.23531	-118.56378	RESTAURANT TI. PC FOR POWER AND ENERGY. OCCUPANT LOAD GREATER THAN 100. LOAD IS BEING REDUCED FROM EXISTING CONDITIONS. building permit 16016-20000-21293	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16549	07041-10002-17156	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood			1911.10	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	10/15/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	REVISED SINGLE LINE DIAGRAM TO SHOW NEW FEEDER TO SUPPLY GUARD SHACK .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16550	12041-10000-07222	7000 W WORLD WAY WEST Terminal 4	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM			Reviewed by Supervisor	04/18/2012 12:00:00 AM	PIN	33.93847109	-118.41935625	Lighting retrofit from existing flourescent to lower wattage flourescent lights and ballast.  (Applicant has been referred to test lab).  Terminal 4.   Per applicant, all emergency lighting is existing and separate, no fixtures used for emergency lighting will be retrofitted - No plan check for emergency lighting on this application.   Building is 24-hour, 365 day operation, no skylights or windows, exempt from auto-shutoff.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16551	13041-10000-12514	1055 W 7TH ST SUITE 1700	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.0507	-118.26334	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. 3875 SQUARE FEET TENANT IMPROVEMENT OF OFFICE BUILDING SUITE 1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16552	13041-10001-33879	2970 W OLYMPIC BLVD	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.05241	-118.29951	expedited per applicants requestNew roof mounted PV system with 31.5 KW include two new subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16553	15041-20000-17227	333 S HOPE ST 55, 57 TH-FLOOR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLANCHECK FOR POWER. REPLACEMENT OF TWO UPS SYSTEMS. ON 55TH AND 57TH FLOOR. ( 75KVA AND 100 KVA).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16554	11041-10000-13726	4900 N VINELAND AVE 1-58	91601	2	168B173   211	2421011002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			07/01/2011 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.1595	-118.37008	New 82-unit 100% Sr. Affordable Apartment with on-grade parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16555	10041-10001-19799	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	33.93195	-118.41136	MODIFICATION TO AN EXISTING SET OF PLANS.  MODIFICATIONS INCLUDE THE ADDITION OF A NEW 75 KVE TRANSFORMER, LOCATION OF KITCHEN EQUIPMENT, CHANGES IN THE PANEL SCHEDULE, AND TITLE 24 CALCULATIONS.  APPROVED SET OF PLANS ARE INCLUDED.  REGULAR PLAN CHECK.<<<<<<<<Remodel inflight kitchen.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16556	18041-10000-48444	9700 W PICO BLVD	90035	5	132A167   270	4307006011	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.05472	-118.39929	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16557	19041-20000-03962	12941 W STRATHERN ST	91605	2	189B161   307	2304015003	(T)RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.21595	-118.41597	Plan check for PV roof mounted system and battery back up system, PV system size: 4.8KW DC, 16 PV Modules and 1 inverter(7.6KW) and 1 LG Chem battery 9.89kWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16558	10041-20000-23487	15986 W ALCIMA AVE	90272	11	129B125   285	4420003020	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2010 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.05076	-118.53501	Roof and Ground mounted total 23.3KW Photovoltaic System for new single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16559	16041-20000-43809	9020-9026 N OWENSMOUTH AVE	91304	3	195B105    35	2779018013	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.23429	-118.60151	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from manufacturing to catering & manufacturing/tenant improvement. Single tenant space has been subdivided to two tenant spaces. Total lighting area = 8,400 sq. ft. Note: Building application has been generated under 16016-20000-20345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16560	14041-20000-26984	11865 W ART ST	91352	6	195B169    52	2631022013	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.23397	-118.39127	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16561	14041-20000-12790	13226 W CANTARA ST	91605	2	192B157  1031		(T)RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.21969	-118.4209	Roof mounted PV system with system size 8.25KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16562	19041-20000-46460	17106 W NANCE ST	91316	5	165B133   369	2292002021	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.14757	-118.50514	PV1.  Install 10.890 kW DC roof mounted grid tied PV system.  (33) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16563	10041-10000-20094	712 S OLIVE ST	90014	9	129A209   198	5144013025	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/08/2010 12:00:00 AM		Permit Finaled	04/28/2011 12:00:00 AM	ADDRESS	34.0462	-118.25568	TI IN AN EXISTING RETAIL AREA ON THE FIRST FLOOR IN THE PLAZA AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16564	18041-10000-09898	8036 S DUNFIELD AVE	90045	11	099B165   484	4109008025	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Issued	05/08/2018 12:00:00 AM	ADDRESS	33.96787	-118.39932	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.2KWdc / 13.4KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16565	19041-20000-27703	7521 N AQUEDUCT AVE	91406	6	186B141   207	2206013018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.20726	-118.47401	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 3.63KW DC/3KW AC. SCOPE OF WORK INCLUDES (11) LG ELECTRONIC PV MODULES AND A NINGBO GINLONG SOLIS-1P3K-4G-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16566	18041-10000-05353	1222 E ANAHEIM ST	90744	15	030B213   125	7424023038	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.78066	-118.24728	REPLACE OUTDOOR AND INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16567	11041-10000-11785	10441 S ANTWERP ST	90002	15	090B209    66	6065017907	PF-1, R2-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	33.94062	-118.24881	EXTERIOR LIGHTING FOR DINING AREA OUTSIDE NEW CLASSROOMPLAN CHK IS FOR TITLE 24; PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16568	15041-10000-33971	5337 E RAPHAEL ST	90042	1	153A227   115	5469026016	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.11445	-118.20068	Installation of new roof mounted solar PV array on existing single family dwelling.  Total systems ize = 3 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16569	19041-10000-23187	5670 W WILSHIRE BLVD 6TH FLOOR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI IN COMMON AREAS & CORRIDORS OF THE 6TH FLOOR. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.  1,099 SQR FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16570	12041-20000-15547	3651 S WATT WAY	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			PC Approved	07/05/2012 12:00:00 AM	ADDRESS	34.02013	-118.28812	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16571	19041-20000-18452	7061 N HAYVENHURST AVE	91406	6	183B137   139	2225003080	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.19903	-118.49255	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN A 2-STORY COMMERCIAL BUILDING. 1 FA PANEL, AND 58 FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16572	18041-10000-24004	11840 W FOOTHILL BLVD Unit #H	91331	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.27349	-118.39431	TI in an existing commercial area in Unit #H (La Michoacana Emerita Ice Cream). Existing Service, Existing Panels and Existing lights to remain. First time tenant. Plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16573	18041-10000-04995	13012 W BLOOMFIELD ST	91604	2	165B161   488	2375013026	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.14921	-118.41652	NEW ROOF MOUNTED SOLAR SYSTEM USING (32) AC MODULES. TOTAL SYSTEM  IS 10.40KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16574	19041-30000-21147	14954 W SHERMAN WAY	91405	6	183B145    94	2220005028	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Apartment			06/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	01/05/2022 12:00:00 AM	ADDRESS	34.20085	-118.45932	Plan check for power and energy.  Work includes an 800-amp service and a total lighting area of 15,393 sq. ft.Note: Building permit has been issued under 16010-20000-03386	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16575	11041-10000-02736	801 N FAIRFAX AVE #7	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1920.00, 1944.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	03/25/2011 12:00:00 AM		Permit Finaled	04/11/2011 12:00:00 AM	ADDRESS	34.08567	-118.36172	Ti for a restaurant. EPC is for power. (T24 was approved under separate application & the inspector asked for a complete plan check.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16576	18041-10000-13358	100 S GRAND AVE	90012	14	132A211    45	5149010949	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	05/10/2022 12:00:00 AM	ADDRESS	34.05536	-118.24876	277/480V, 3 PH, 5,000 AMP TEMPORARY POWER FOR CONSTRUCTION OF 2 HIGHRISE BUILDINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16577	18041-10001-23390	1633 W 70TH ST	90047	8	102B193   921	6015027013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM			PC Approved	09/27/2018 12:00:00 AM	ADDRESS	33.97629	-118.30566	EXPEDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 25 MODULES WITH OPTIMIZERS WITH SINGLE INVERTER (ESS ON SUPP. PERMIT 10002)SYSTEM SIZE 7.6KWAC/8.125KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16578	17041-20000-43820	17158 W KILLION ST	91316	5	174B133   718	2258002007	RE11-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.17076	-118.50761	PV1.  Install 10.5 kW DC roof mounted grid tied PV system.  (30) modules with central inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16579	15041-20003-19359	9126 N LANGDON AVE 1-15	91343	7	198B145   349	2656026027	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Apartment			12/07/2018 12:00:00 AM			PC Approved	12/07/2018 12:00:00 AM	ADDRESS	34.23653	-118.46964	"12-07-2018 Changes to an approved set of plan, Changes include remove DB -2 distribution and replace with HP panel, reconfigured circuits, all loads to remain the same. All Changes apply to delta ""A"" only. Plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16580	16041-10000-14813	5901 W CENTER DR	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			08/26/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	33.97509	-118.38703	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 375 UNIT 6 LEVEL APARTMENT BUILDING WITH ONE LEVEL MEZZANINE OVER  2 STORY PARKING GARAGE. SCOPE INCLUDES 2 FA PANELS, 1263 FA DEVICES, AND 2 COMMUNICATION PANELS. NOTE: PLAN CHECK FOR PHASE 2 CONSTRUCTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16581	14041-20001-19126	11315 N MONOGRAM AVE	91344	12	210B137    51	2681014010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Expired	09/08/2016 12:00:00 AM	ADDRESS	34.27598	-118.49249	$0 permit fee due to senate bill 1222 from 2012change in module size. now using 275w panels. addition of 1 module. now using 21 in total. system size 5.2kw ac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16582	17041-10001-40165	1541 N WILCOX AVE	90028	13	147A187    22	5547017003	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			PC Approved	02/08/2018 12:00:00 AM	ADDRESS	34.09913	-118.33128	PC FOR REVISIONS TO APPROVED SET DUE TO FIELD CHANGES AND INSPECTION. ALL CHANGES UNDER DELTA 2.SCOPE INCLUDES FEEDERS RESIZE.THIS IS PLAN CHECK ONLY!PC for power for temporary power installation. Connecting to existing 1600A 120/208V service in adjacent empty building (1545 N Wilcox Ave) owned by same owner.  Installing transformers, hoists,cranes, swing stage and placing boom. Architectural floor plan for future building layout shown on E1.01 for reference only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16583	19041-10000-22457	1439 W 70TH ST	90047	8	102B193   893	6015025024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Refund in Progress	02/24/2020 12:00:00 AM	ADDRESS	33.9763	-118.30155	Plan check for a PV1 3.8KW AC/ 4.3KW DC roofmounted system with (1) inverter, (15) modules and optimizer interconnecting through the main service apnel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16584	11041-10000-04127	1440 W FRANCISCO ST	90501	15	057B193   128	7351037018	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	33.85006	-118.30076	TENANT IMPROVEMENT BUILD OUT OF EXISTING SHELL MEZZANINE. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16585	14041-10001-17066	15610 W MOORPARK ST UNIT 7	91436	5	168B141   602	2261029***	R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Apartment			06/26/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	PIN	34.1559257	-118.47396414	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{[PV1, INSTALL 8.925 KW DC ROOF-MOUNTED SOLAR ARRAY ON A PARTMENT BUILDI NG, INTERCONNECT WITH MAIN SERVICE PANEL.(2) INVERTERS: SOLAREDGE SE3000A-US-ZB-U AND SE5000A-US-ZB-U(35) MODULES:TRINA SOLAR TSM-255PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16586	17041-10000-06212	2029 S CENTURY PARK EAST 10th FL-CORRIDOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Issued	03/07/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY. INTERIOR RENOVATION OF PUBLIC LOBBY ON THE 10TH FLOOR, CORRIDOR . CONNECTED LOAD < 400A. AFFECTED AREA 1875 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16587	14041-10000-05451	700 N FAIRFAX AVE	90046	5	141B177   515	5527011005	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.0841	-118.36119	FULL PLAN POEWER AND ENERGY(RETAIL TO REATURANT) TOTAL AREA 887 SQ FT.PANEL R2 TO BE DELETED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16588	19041-10001-10716	1580 E JESSE ST	90021	14	124-5A217 119	5164018010	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.03625	-118.22968	Changes to approved T-24 set. Changes to lighting fixtures and layout. Update wattages to match installed conditions. Scope also includes installation of new 100A panel.  ((Energy plan check for an INTERIOR TENANT IMPROVEMENT TO EXISTING BUILDING. Scope includes new lighting and equipment with a total area of 10,784-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16589	14041-20000-08933	14123 W VICTORY BLVD	91401	6	180B153  1049	2237019025	[Q]CR-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.18683	-118.44088	new fire alarm system consisting of 36 new devices and new fire alarm control panel. pc for fire alarm system only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16590	16041-20000-24566	18119 W TOPHAM ST	91335	3	177B125  1045	2124015049	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.18082	-118.52811	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16591	12041-10000-02803	5333 W ZOO DR	90027	4	162B197     2	5593002905	OS-1XL	Central	Hollywood	Greater Griffith Park	YES	9800.09	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.14867	-118.28623	New fire alarm system for rainforest exhibit at the LA ZOO.  No building or suite number per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16592	19041-20000-19673	15233 W VENTURA BLVD Ste 320	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			PC Info Complete	05/23/2019 12:00:00 AM	ADDRESS	34.1538	-118.46502	TI to (E) commercial office in highrise office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16593	13041-10000-14363	3651 S WATT WAY 206;210-214;217	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.02013	-118.28812	PLAN CHK TO VERIFY THAT LUMINAIRES IN ROOMS206;210214217 ARE IN COMPLIANCE WITH TITLE 24 AFTER BEEN REMOVED AND CLEANED AND PUT BACK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16594	18041-10001-47322	10333 N KEOKUK AVE	91311	12	204B113    87	2707016009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.25876	-118.57419	EXPEDITE FEE FOR A NEW 15.2 KW AC ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOME WITH 55 PV PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16595	10041-10000-25673	811 W WILSHIRE BLVD # 550	90017	9	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	05/02/2011 12:00:00 AM	ADDRESS	34.04973	-118.2584	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16596	13041-10000-10735	333 S HOPE ST 17TH FL	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	13041-10000-10735 REMODELING EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCDY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16597	12041-10000-03530	9540 N VAN NUYS BLVD	91402	6	201B149   735	2644025901	P-1VL, RD2-1, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Info Complete	06/14/2012 12:00:00 AM	ADDRESS	34.24411	-118.45004	Plan check fire alarm system for new City of LA Multipurpose Center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16598	19041-20000-25135	20135 W JUBILEE WAY pv1	91326	12	213B113   412	2701087040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.28259	-118.57288	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.95KWdc / 11.2KWac.(35) AC MODULES- SUNPOWE SPR-X22-370-E-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16599	16041-20000-44230	1449 N AVENUE 46	90041	1	156A221   146	5474026007	M1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1834.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.12209	-118.21645	remove existing hid fixtures and replace with new led fixtures.  plan check for energy indoor/ outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16600	12041-10003-13130	929 S BROADWAY	90015	14	127-5A209 256	5139003005	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.04174	-118.25687	REVISIONS TO SINGLE LINE DIAGRAM-REPLACING OLD PANELBOARDS AND RECONNECT EXISTING LOADS TO NEW PANELS; NEW PANELS WILL BE SUPPLIED FROM NEW SWBDS ((((((((REVISED SINGLE LINE TO SHOW THAT FEEDERS ARE ALL ALUMINUM IN EXISTING CONDUITS.;REPLACE TRANSFORMERS FOR LESS AVAILABLE SHORT CIRCUIT CURRENT((((((((((Change of use from an office to a hotel, 13-story building.  1000A service.  Full plan check.  Variance will be filed to separate fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16601	13041-10000-15587	4342 N BABCOCK AVE 1-9	91604	2	165B161   399	2375002026	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			06/13/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.14982	-118.40612	New 70 device fire alarm system for a 3-floor 9 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16602	14041-20000-04287	9550 N YOLANDA AVE	91324	12	201B121   707	2763003020	RA-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.24428	-118.54031	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING DC COMBINER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16603	19041-10000-11165	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	33.78054	-118.23195	INSTALLATION OF APPROX 1,000 FEET OF DUCT BANK FOR THE FUTURE MV SUBSTATION FED FROM A 1,500KVA TRANSFORMER AT 4,160V IN A METHANE ZONE IN VALERO REFINARY (CLASS 1 DIV 1). The installation of Feeders, Transformer & Substation are NOT included in this phase of the project.Note. all duct bank shall be recheck after cable is installed in the conduits. THIS IS PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16604	18041-20000-38954	2142 S PONTIUS AVE 3rd fl	90025	5	126B153   628	4322025046	[Q]P-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.04026	-118.43869	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16605	13041-20000-21584	23741 W KILLION ST	91367	3	174B089   597	2047010002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.16999	-118.64505	PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 11.13 KW. 42 MODULES AND 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16606	19041-10000-44935	12746 W JEFFERSON BLVD	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check for a PV2 129KW AC / 160KW DC roofmounted system. Scope include 370-module, (2) inverter interconnecting throgh the main service panel.PERMIT FEE $ 0 IS DUE TO  AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16607	14041-10000-21793	12708 W CASWELL AVE 1-5	90066	11	111B153  1021	4236019003	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	33.99851	-118.43634	installation of a new fire alarm system for 4 story apartment building. 5 uints. 1 facp and 45 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16608	14041-10000-07117	2580 W OLYMPIC BLVD	90006	1	129B197   330	5076008018	[T][Q]C2-1, [T][Q]P-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Expired	07/14/2016 12:00:00 AM	ADDRESS	34.05219	-118.28726	New 3-story commercial building with roof deck. Tenant improvement for Unit 4 included in this permit. (Shell only for Units 1, 2, 3 and 5)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16609	12041-20000-30259	11390 W OLYMPIC BLVD ste 400	90064	11	123B153    61	4260018021	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.03709	-118.44273	Plan check for energy and emergency lighting. 4th Floor of low-rise commercial. 7532 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16610	17041-20000-26112	8833 N MCLENNAN AVE	91343	12	195B133   271	2688028028	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Issued	08/07/2017 12:00:00 AM	ADDRESS	34.23118	-118.50102	Plan check for the addition of a Tesla PowerWall to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16611	13041-20000-26883	242 N COPA DE ORO ROAD	90077	5	141B153   238	4362021005	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.08011	-118.43982	PC FOR POWER. SINGLE FAMILY DWELLING. 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16612	14041-20000-16033	12411 W SHELDON ST 5B	91352	6	195B165   204	2629019015	(T)(Q)C1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.23261	-118.40328	Tenant improvement interior alteration. existing retail, New lighting. prep for future tenant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16613	13041-10001-33990	11436 N OSTROM AVE	91344	12	213B133   749	2697017034	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.27844	-118.50694	][]EXPEDITED PER APPLICANT REQUEST ][][]PV1, ROOF-MOUNTED SOLAR INSTALLATION IN SINGLE STORY HOME. SYSTEM IS TRANSFORMERLESS & SIZE IS 3.6 kW ON NON-STANDARD PLAN. TOTAL NUMBER OF MODULES IS 15, IN 3 STRINGS VIA DC COMBINER BOX. (15) MODULE: SUNPOWER SPR-327WATT(1) INVERTER: POWER-ONE PVI-3.6-OUTD-US-240V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16614	19041-20000-04021	20516 W ESMERELDA LANE	91326	12	216B109   198	2701081047	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.29048	-118.58075	PV1.  Install 5.985 kW DC / 5.0 kW AC roof mounted grid tied PV system.  (21) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16615	18041-10000-04498	455 E 3RD ST	90013	14	129A215   242	5161020005	R5-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Public Safety Only			02/07/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.04669	-118.24067	REPLACING MAIN FACP1 LOCATED ON THE 1ST FLOOR AND THE NODE FIRE ALARM PANEL FACP2 LOCATED ON THE 12TH FLOOR AND ASSOCIATED ANNUNCIATORS AND AUX POWER SUPPLIES.ALL FA DEVICES REMAIN IN IN PLACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16616	14041-20000-03539	12610 W HAVELOCK AVE	90066	11	105B157   500	4221027030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	33.98428	-118.42274	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16617	15041-10002-18140	1063 S WOOSTER ST	90035	5	132B169   422	4332016034	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			05/24/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	11/30/2021 12:00:00 AM	ADDRESS	34.05743	-118.38271	"Changes to an approved set of plans. Changes include upgrading the elevator from 30hp to 40hp, changing breaker to elevator, and relabling house panel to ""HDP""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16618	19041-20000-48507	10228 N ENCINO AVE	91325	12	204B129   216	2734026003	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	07/10/2020 12:00:00 AM	ADDRESS	34.25646	-118.5153	PV1 PLAN CHECK FOR NEW PV. SYSTEM SIZE IS 8.99 KW DC/7 KW AC. SCOPE OF WORK CONSISTS OF (29) PV MODULES AND A 7 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16619	10041-10000-06900	12975 W JEFFERSON BLVD	90066	11	102B157    93	4211008026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM			Verifications in Progress	06/02/2011 12:00:00 AM	ADDRESS	33.97533	-118.42387	replace existing emergency stand-by generator with new 150kw emergency stand-by generator. permit already obtained in application # 09041-20000-22127. plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16620	15041-10000-12036	380 WORLD WAY T 93	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 plan check only.  Total area = 360 sq. ft.T.I. to existing commercial kiosk in the airport.  Lighting, recepticles, and one new 225A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16621	19041-20000-52381	7953 N GENESTA AVE	91406	6	189B133   441	2204020015	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	ADDRESS	34.21534	-118.50417	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV. SYSTEM SIZE IS 11.52 KW DC/10 KW AC. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS AND A 10 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16622	16041-20001-45449	500 S GRAMERCY PL	90020	4	135B193   671	5504029017	R4-2	Central	Wilshire	Greater Wilshire		2117.04	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.0651	-118.31263	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16623	12041-10000-11997	1441 W OLYMPIC BLVD #220-260	90015	1	129A205   148	5137005021	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.04841	-118.27203	T.I. to an existing office building on the second floor.  New lighting, receptacles, load is less than 200A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit is for lighting and receptacles all on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16624	19041-10002-21780	15303 W VENTURA BLVD 5TH FLR	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	Changes to approved set.  Scope of work is revision to lighting plan to include the restrooms and showing the exit signs, and reflecting the emergency generator. Orginal permit has been pulled.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16625	19041-10000-43968	9440 N LURLINE AVE	91311	12	198B109   205	2748041033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	01/22/2021 12:00:00 AM		Permit Finaled	02/21/2023 12:00:00 AM	ADDRESS	34.24177	-118.58401	per ab# 1414 fees are $0.00PV2 PC FOR A FEED IN TARIFF. NEW ROOFTOP SOLAR SYSTEM . SCOPE INCLUDES 540 MODULES (LG400), 270 OPTIMIZERS (P850), 1 INVERTER ( SE 100KUS) AND 1 INVERTER ( SE 66.6KUS). SYSTEM SIZE IS 216.00 KWdc (166.6 KWac). FEEDING INTO AN (E) 400 AMP SOLAR PANELBOARD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16626	14041-20000-08656	5926 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.10524	-118.18409	Installation of two 100A subpanels and associated wiring for two commercial retail/office spaces.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16627	17041-10000-29272	100 E SWINFORD ST BERTH 92	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	33.74854	-118.2791	PC for new fire alarm system with 150 devices and pne FACP (Berth 92 FACP). Note that this system is using 29V power supply for simplex notification devices and a 24V power supply for the non-simplex notification devices as specified in the manufacturers cutsheet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16628	15041-10000-08591	520 S OLIVE ST	90013	14	129A211    32	5149031900	OS-1XL	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.0488	-118.25326	Energy plan check for a 3-level parking structure, replacing existing lighting fixture. Total area is 628,236-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16629	07041-10004-27321	2311 W 10TH ST 1-27	90006	1	130-5A201  49	5136004016	R4-1	Central	Westlake	MacArthur		2095.10	Electrical	Electrical	Apartment			04/06/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.05314	-118.28223	CHANGES TO THE APPROVED PLANS.  REVISED PANEL SCHEDULE IN THE UNITS AND CHANGES TO THE HOUSE SERVICE.New 27 unit apartment with 2 subterranian parking and 4 level above grade (6 typical).  New service 1600amp, 120/240v, 1ph, 3w.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16630	17041-10000-20353	1853 E 1ST ST	90033	14	129A221   205	5174014012	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.04696	-118.21799	Plan check for power and Title 24.  New 2 story building with restaurant on ground floor (A occ.) and office on 2nd floor (B occ.).  New 600 amp 120/208 volt service with 3 subpanels and elevator.  Lighting area = 5,250 sq. ft. (indoor) + 3,765 sq. ft. (outdoor)       Building permit #16010-10000-04393	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16631	12041-10001-05159	1510 N SAN PABLO ST 6TH FLOOR-Phase III	90033	14	135A225    62	5202004039	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.06266	-118.20215	"Energy Only. Tenant improvement. Sixth floor of USC office building. Phase 3 consistes of 1945 sqft. Lighting and E mergency Lighting Plan Check. phase 2 WAS DONE UNDER APPLICATION # 12041-10000-05159  PERMIT FEES ARE UNDER ""INSPECTION"" FEE SCHEDULE <<<Complete Plan Check may be required subject to field inspection>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16632	16041-10000-24382	2250 E 114TH ST	90059	15	087A217   275	6067013901	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	33.93128	-118.23249	PC FOR ENERGY ONLY. REPLAEMENT OF HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 7200 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16633	18041-20000-46747	6247 N ORION AVE	91411	6	177B145   186	2242005002	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.18437	-118.47007	Plan check for a PV1 roof-mounted PV system. System size is 14.52 kWdc/12.34 kWac-CEC and consists of (44) modules, (44) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16634	14041-10001-18822	300 S SANTA FE AVE	90013	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	CHANGES TO APPROVE SET. PC FOR POWER AND ENERGY ON DELTA 4. ADDING NEW REFRIGRATION SYSTEM.  (((PLAN CHECK FOR POWER AND ENERGY.   FIRST TIME TENANT PER APPLICANT.BUILDING P# 14016-10000-09782. Tenant improvement for grocery store.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16635	18041-10000-34624	1149 S BROADWAY	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	ADDRESS	34.03859	-118.26015	Energy plan check for an office T.I located on the 7th floor of a high rise building. Scope includes new lighting and equipment with a total area of 3322-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16636	13041-10000-13555	11111 W SANTA MONICA BLVD SUITE 1700	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	permit to be pulled at EPC counter only. ti to existing building. office to another office. 17th floor. INTERIOR NON-STRUCTURAL ALTERATION TO EXISTING OFFICE SPACE: NEW DEMISING WALL TO SEPARATE TANENT SPACE (6,230 SQ FT AND 1,567 SQ FT): NEW NON-BEARING PARTITIONS, CEILING, MILLWORK AND FINISH; (AREA OF WORK 4,000 SQ FT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16637	19041-20000-52782	2532 N CANYON OAK DR	90068	4	154-5A191 354	5580023027	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/03/2021 12:00:00 AM	ADDRESS	34.11583	-118.31454	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 20.79 KW DC/17.6 KW AC. SCOPE OF WORK CONSISTS OF (63) PV MODULES WITH MICROINVERTERS, A LOAD CENTER,, A 7.6 KW INVERTER, AND A 10 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16638	15041-10001-03206	724 S SPRING ST Unit 202-204	90014	14	127-5A211 131	5144015041	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM			PC Approved	10/30/2015 12:00:00 AM	ADDRESS	34.04384	-118.25268	TENANT IMPROVEMENT/CHANGE OF USE FROM OFFICE TO DANCE STUDIO IN A COMMERCIAL HIGH RISE BUILDING. TOTAL AREA 3188 SQ FT.  PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16639	17041-20001-23238	9430 N TOPANGA CANYON BLVD 1st & 2nd-fl	91311	12	198B101   335	2746013041	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.24159	-118.60598	09/22/20178 Changes to an approved set of plans. There have been changes made to circuit designations and home-runs. Emergency egress lighting photometric analysis has been provided.*****Previous Work Description*****ti to an existing commercial building two story.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 4415	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16640	14041-10000-09655	12501 N GLADSTONE AVE B-4	91342	7	219B161   211	2525018061	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.29709	-118.41363	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16641	19041-10000-37185	828 N EUBANK AVE	90744	15	030B209   138	7423024031	[Q]MR2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM	ADDRESS	33.78127	-118.25488	PC for power only. Emergency Homeless Shelter. Tensile Membrane Structure, 100 beds total. A Bridge Home. Scope includes 400A 480/277V 3 phase 4 wire service/distribution board, new panels, new transformers, and new circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16642	14041-10000-25394	6240 E YORK BLVD	90042	14	153A231   440	5492034008	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.11486	-118.18317	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. NO CHANGE IN OCCUPANCY. OUTDOOR LIGHTING. 878 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16643	16041-30001-25426	1506 N BAY VIEW AVE	90744	15	036B205   802	7421015026	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	33.79324	-118.27082	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (18) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16644	19041-10001-43549	21536 W DEVONSHIRE ST	91311	12	204B105   833	2747025038	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.25698	-118.60044	***Expedite Fees***ROOF TOP SOLAR PLAN CHECK FOR 30KWac (34.127 KW CEC AC) (38.28 KWdc) USING 116 AXITEC-AC-330P/156-72S MODULES, 116 SOLAREDGE P400 OPTIMIZERS, AND 3 SOLAREDGE SE10000H-US INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16645	14041-20000-21970	5510 S LINCOLN BLVD #425	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	33.97299	-118.43051	OFFICE TI. NEW SUBPANELS, LIGHTING AND POWER. PLAN CHECK FOR T24 ENERGY ONLY. TOTAL AREA 5706 SQ FT. WORK DONE ON 4TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16646	19041-20000-41055	11881 W TERRA VISTA WAY #109	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/12/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16647	18041-20000-48475	13541 W DESMOND ST	91331	7	210B157    39	2523004043	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	11/08/2023 12:00:00 AM	ADDRESS	34.27569	-118.42748	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from storage to hydroponic agricultural enterprise. Total lighting area = 9,464 sq. ft.Note: Building application has been generated under 18016-10000-38179	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16648	17041-10002-18987	2222 N MARAVILLA DR	90068	4	150B181   103	5549013025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	ADDRESS	34.11034	-118.34337	EXPEDITE FEESROOF MOUNTEDPV SYSTEM WITH BATTERY STORAGE. NEW PV SYSTEM RATED 6.6KW AC USING 21 MODULES. BATTERY SYSTEM 5.8KW WITH 13KWH STORAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16649	15041-10003-32635	811 W 7TH ST 11TH FLR	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	ADDRESS	34.04908	-118.25911	"PC FOR LOST SET OF PLANS.SUBMITTAL PER APPLICANT REQUESTTHIS IS ""PLAN CHECK ONLY""!11/8/2017 SCOPE TO REMAIN THE SAME: T-24. PC FOR ENERGY ONLY.  FULL FLOOR TENANT IMPROVEMENT AT THE 11TH FLOOR OF AN EXISTING OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTING AND TWO NEW PANELS. TOTAL AREA IS 7738 SQ. FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16650	18041-20000-06702	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	33.98722	-118.47211	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the indoor lobby and the outdoor hotel entrance. Total indoor and outdoor lighting area = 2,385 sq. ft.Note: Building application has been generated under 17016-10000-00997	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16651	16041-10000-41370	4900 E CLELAND AVE	90042	1	153A223   139	5477026049	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.11444	-118.21114	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING TO MORE ENERGY EFFICIENT. permit will include soccer field area which will not be plan checked - exempt from T24 calculations.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16652	14041-20000-16745	5764 N CHICOPEE AVE	91316	5	174B129   227	2254020020	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.17592	-118.51212	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16653	16041-10000-08063	351 S BROADWAY	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.04997	-118.24929	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO TAKE OUT RESTUARANT. SCOPE INCLUDES NEW 600A DISTRIBUTION BOARD, 4 SUBPANELS, AND NEW LIGHTING. TOTAL AFFECTED AREA IS 4417 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16654	14041-10001-24456	10955 W PEORIA ST	91352	7	201B173   311	2538014015	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.24668	-118.36936	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE3800A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16655	15041-10000-11351	380 WORLD WAY T92C	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM			PC Info Complete	06/18/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for a retail store (currency exchange) , T92C, located inside the airport .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16656	14041-20001-30932	4740 N VIVIANA DR	91356	3	168B117   382	2178018018	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM			PC Approved	12/01/2014 12:00:00 AM	ADDRESS	34.15584	-118.55423	EXPEDITED PER APPLICANT'S REQUESTPV1 ROOFMOUNTED SOLAR SYSTEM. NON STANDARD CENTRAL INVERTER. SYSTEM SIZE 10260W DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16657	17041-20000-11934	8700 N VAN NUYS BLVD	91402	6	195B149   659	2638001034	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.22745	-118.4499	TENANT IMPROVEMENT TO MARKET.   PLANCHECK FOR POWER AND ENERGY. BUILDING PERMIT # 17016 20000 06946	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16658	12041-10000-02379	5822 S VERMONT AVE	90044	9	108B197  1460	6004001023	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	33.9889	-118.28954	New check cashing store added to an existing supermarket.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16659	13041-10000-20793	16906 W MARLIN PL	91406	6	183B133   629	2230006014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.197	-118.50164	PLAN CHECK FOR PV1 ROOF MOUNTED INSTALLATION ON A MICROINVERTER STANDARD PLAN. SYSTEM SIZE IS 4.32 KW AC AND 5 KW DC. [INVETER: ENPHASE # M215-60-2LL-S22 |||| MODULE: REC # REC 250 PE]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16660	18041-20000-36316	6015 N WOODMAN AVE	91401	2	177B157   812	2239023003	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	Apartment			09/24/2018 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.17982	-118.43144	new apartment building 600 amp service 3 story 14 units.  plan check for power and energy.building application number 16010-20000-06148	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16661	19041-10000-02709	11601 W WILSHIRE BLVD 108	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC T-24 ONLY  FOR INTERIOR TENANT IMPROVEMENT TO CONSTRUCT A PREPACKAGED FOOD SALES IN (E) FOOD ESTABLISHEMENT (1st floor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16662	17041-10000-25056	7955 N VINELAND AVE	91352	6	189B173   272	2314007085	[Q]C2-1L-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.21536	-118.37053	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AREA IS 19200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16663	13041-20000-15340	18626 S WESTERN AVE	90248	15	060B193   277	6108002021	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	33.86124	-118.30895	PV2 for commercial. 21kW total AC, (3) 7kW Inverters. 400A service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16664	16041-10012-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM			PC Approved	07/22/2019 12:00:00 AM	PIN	34.2363795	-118.55851216	PC FOR CHANGES TO APPROVED SET UNDER DELTA 29. SCOPE INCLUDES CHANGES TO LIGHT FIXUTRES SCHEDULES.  NEW RECEPTACLES AND NEW FIXUTRES IN LEVEL 2 LOBBY. ALL CHANGES CLOUDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16665	19041-10000-48060	14204 S FIGUEROA ST	90061	15	075B201    50	6132044016	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	33.90242	-118.28255	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY.OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16666	17041-10000-15832	8700 W BEVERLY BLVD #189	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Closed	07/28/2017 12:00:00 AM	ADDRESS	34.07666	-118.3805	PC FOR OFFICE UPGRADE AND LAB UPGRADE. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16667	18041-20000-42957	5946 N MAURY AVE	91367	3	177B085   502	2032017001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Issued	11/08/2018 12:00:00 AM	ADDRESS	34.17865	-118.66082	PV1.  Install 6.38 kW roof mounted grid tied PV systems.  (22) modules with 6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16668	13041-10000-15838	11150 W SANTA MONICA BLVD 11TH FLOOR	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI to highrise offices on the 11th floor.  New lighting and receptacles, conversion of conference room into office rooms.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16669	13041-10002-12998	380 WORLD WAY Space T26	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED FIRST TIME  TENANT IMPROVEMENT N SPACE T26  (TBIT ). ((((((    4-1-14  mz   relocation of lights and reduction of watts  per inspector up date plans.))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16670	17041-10000-15957	600 W WILSHIRE BLVD #900	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.04796	-118.25622	PC for energy only. Indoor Title 24. Interior TI on suite 900. New lighting and power of existing offcie floor. Area: 10,578 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16671	09041-20001-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM			PC Info Complete	12/14/2010 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 31	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16672	14041-20001-04891	14006 W RIVERSIDE DR #270	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM			PC Approved	03/24/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Change to approve set of plan. Replace the light fixture in the plan to match it in the field. (((((((T.I. to existing building Space #270. Install general/emergency lighting. Plan check for energy only.Note: Permit is under a separate application))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16673	13041-10000-24054	18200 W GUILDFORD LANE	91326	12	213B125   404	2870013043	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Expired	09/30/2015 12:00:00 AM	ADDRESS	34.27942	-118.5317	PV1. ROOF MOUNTED SOLAR ARRAY. CENTRAL INVERTER. SYSTEM SIZE: 8.82 KW. 36 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16674	15041-20000-13315	6316 N TOPANGA CANYON BLVD B-2110	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.18578	-118.60514	TI to new commercial building (fitness studio). Plan check for power and energy. Adding new lighting including emergency. Total sqft. 5,442.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16675	10041-10000-08502	5851 W CLINTON ST	90004	4	141B185   645	5523005003	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	09/22/2010 12:00:00 AM	ADDRESS	34.08176	-118.32967	Title 24 energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16676	17041-30000-26123	612 S COCHRAN AVE	90036	4	135B181   640	5508009028	[Q]R4-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Apartment			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.06445	-118.34708	Plan check for replace new fire alarm panel with existing fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16677	15041-10000-27319	3235 S HUTCHISON AVE	90034	10	123B169  1780	4312016040	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.03074	-118.38369	NEW FIRE ALARM SYSTEM TO AN AUTOMATEDPARKING STRUCTURE AND SHELL OFFICE SPACE. (21) DEVICES, (1) FIRE ALARM PANEL AND (1) COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16678	13041-10001-27352	4554 N WORTSER AVE	91604	2	168B161   952	2362008001	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.1538	-118.41694	�Expedited plan check per applicant request�.PV1 8.64KWAC 240V MICROINV 1STORY. nonSTD. ROOFMOUNT.[( 40) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: suntech STP255S-20WDB]. Main service panel being upgraded from 200A to 225A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16679	15041-10001-16734	5434 W 77TH ST	90045	11	099B173   335	4127015017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	33.9678	-118.37576	EPEDITED FEE FOR PV1 SUBMITTAL. PV1 ROOF MOUNTED SYSTEM, 27 MODULES AND 1 INVERTER 6K. TOTAL SIZE 7.02 (27) KYOCERA # KU2606XPA (1) ABB #PV1-6000-OUTD-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16680	15041-10002-28085	4226 E VERDANT ST	90039	13	159B205   455	5594006029	[T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.13138	-118.26456	[[[ CHANGES TO APPROVED SET. PLANCHECK ONLY.  DELTA 6 REVISIONS ONLY. NEW P2M2A PANEL , LOADS AND SHOWING LOCATION OF SOLAR POWERED PARKING LOT LIGHTING. ]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16681	13041-10000-26903	905 E 2ND ST 1-320	90012	14	129A215   203	5163004005	(T)(Q)C2-2D	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Expired	10/22/2015 12:00:00 AM	ADDRESS	34.04729	-118.23499	This is atemp power for a crane, man lift and spider box.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16682	12041-10000-07728	515 S FIGUEROA ST suite 1400	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	alterations in existing officesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16683	10041-10002-21655	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	Delta 3 modification to previously approved plan page E--112 dated January 1st, 2011.  See application number  10041-1000-21655, approved January 1, 2011.  The extent of work is the relocation of the elevator room, branch circuit L2-26, 28, and the elevator disconnect to new location.  Also on page E-142,  reconnect circuit ER2A-13, 15, and supply an added receptacle outlet, and J-box,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16684	15041-20001-06666	17965 W MAYERLING ST	91344		216B129   169	2601029015							Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM	ADDRESS	34.28804	-118.52425	Expedite per applicant request(((((Plan check for PV roof mounted 1.1 kW with centural inverter 50 modules.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16685	16041-20000-43726	801 S HOPE ST 1st Floor	90017	14	129A209   268	5144030***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.04656	-118.25938	Change of use from retail shell space to new restaurant in (E) commercial highrise building.  Plan check for power and energy.Building permit under 16016-10000-24941	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16686	16041-20000-14707	16540 W RINALDI ST	91344	12	213B137   618	2681001004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.279	-118.49259	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (28) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16687	18041-10000-22306	1318 N NORTH SPRING ST	90012	1	136-5A217  91	5409006051	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.06632	-118.23289	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16688	15041-10000-12882	21221 W OXNARD ST	91367	3	177B105    59	2149005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Apartment			04/29/2015 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.17943	-118.59525	Six story mixed-use building with 379 dwelling units (including 101 Work-Live units), Building Permit 15010-10000-00387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16689	18041-20001-29922	12218 N SARAZEN PL	91344	12	216B137    61	2609011011	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM			Reviewed by Supervisor	08/22/2018 12:00:00 AM	ADDRESS	34.29158	-118.49608	expeditepv1install roof mounted pv system sized 10.4KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16690	12041-20000-16934	15640 W ROSCOE BLVD	91406	6	192B141   489	2673022036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1174.04, 1275.10	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.2211	-118.47407	New service for existing building.  Install two new panels and reconnect existing circuits.  No change in interior lighting, no new circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16691	18041-20000-14772	20650 W WALNUT CIR	91326	12	219B109   358	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.2941	-118.58403	PC for rooftop solar for 3.84kW(ac)/4.02kW(dc) for SFD tract home. Installing 12 AC modules with AC disconnect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16692	13041-10000-13014	811 W WILSHIRE BLVD	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.04973	-118.2584	TI to existing highrise building tenant space (office).  New lighting and receptacles.  Plan check for Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16693	15041-20000-42834	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM			PC Info Complete	02/09/2016 12:00:00 AM	ADDRESS	33.76094	-118.29308	Plan check for Title 24 only in exisitng space (Targe) T.I. in various departments. Total area: 6,991 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16694	15041-10000-21053	720 N ALEXANDRIA AVE	90029	13	141B197   395	5538008023	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Expired	06/04/2018 12:00:00 AM	ADDRESS	34.08427	-118.29771	PV2, INSTALL 21.200KWDC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE WITH THE MAIN SERVICE PANEL.(80) MODULES: LG MONO X NEMO LG65S1-B3(5) INVERTERS : SMA AMERICA SB 3000TL-US-22AND 3800 AND 5000 TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16695	10041-10000-02294	6301 W HOLLYWOOD BLVD	90028	13	148-5A187 147	5546004015	C4-2D-SN	Central	Hollywood	Hollywood United		1902.00, 1910.00	Electrical	Electrical	Commercial			02/09/2010 12:00:00 AM	02/09/2010 12:00:00 AM		Permit Finaled	04/21/2010 12:00:00 AM	ADDRESS	34.10178	-118.32691	Outdoor Parking Lot - T-24 Energy plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16696	19041-10000-10775	6363 W WILSHIRE BLVD #425	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.06385	-118.3674	PC FOR ENERGY ONLY. REMODEL OF EXISTING OFFICE SPACE FOR NEW TENANT. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECETD AREA IS 2224 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16697	19041-20000-07023	24249 W HATTERAS ST	91367	3	174B089    55	2046004005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.17639	-118.65407	PV1.  Install 11.77 kW AC roof mounted grid tied PV system.  (36) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16698	14041-20001-26183	23839 W SYLVAN ST	91367	3	177B089   105	2033019001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.18437	-118.64601	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNETED WITH MSP.(28) KYOCERA KD255GX MODULES(28) POWER OPTIMIZERS (1) SOLAR EDGE SE6000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16699	16041-20001-45787	20908 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Approved	03/31/2017 12:00:00 AM	ADDRESS	34.21969	-118.58915	[[[ 3/31/17 CHANGES TO APPROVED. PLANCHECK ONLY. DELTA 1 CHANGES CLOUDED. SERVICE EQUIMENT MOVED TO OUTSIDE ]]]]]New service for a 7-11 store. #20908.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16700	18041-10000-21978	2049 S CENTURY PARK EAST Suite#1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN AN EXISTING OFFICE AREA IN SUITE #1940 ON THE 19TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16701	15041-20001-12892	10814 N WILLOWBRAE AVE	91311	12	207B105   100	2722019037	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM			PC Approved	05/18/2015 12:00:00 AM	ADDRESS	34.26693	-118.59851	Expedited per customer request.PV1. Install roof mounted PV system sized 14.6 kW. Interconnected with main service panel. (69) Kyocera KU255 Modules(1) PVI 3.6 TL Inverter(1) PVI 6000 TL Inverter(1) PVI 5000 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16702	10041-10000-09475	14006 W RIVERSIDE DR #244 & 301	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	"TI IN AN EXISTING COMMERCIAL SPACE # 244 & 301 ""FOREVER 21"".   PLAN CHECK IS FOR POWER & ENERGY.  FIRE ALARM WILL BE SUBMITTED UNDER A SEPERATE PLAN."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16703	16041-20001-14113	340 S MAIN ST 1st Floor	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	33.99519	-118.47673	Revisions to approved set: removal of normally-off unit equipment emergency egress lighting, change of source of emergency power to emergency inverter.  Plan check for energy only.  Revisions to sheets E2.1 and E3.1 only.  (((Plan check for energy only. INTERIOR TENANT IMPROVEMENT AT LOBBY. New lighting (incl. emergency) and receptacles. 840sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16704	15041-20000-28731	140 S RENO ST 1-109	90057	13	136-5A201  20	5155004025	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM			Reviewed by Supervisor	10/02/2015 12:00:00 AM	ADDRESS	34.07028	-118.28178	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 175KW(480) LG365 MODULES(6) SMA 24000TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16705	14041-20000-12038	12655 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97753	-118.41457	pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #1. 1/3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16706	16041-10000-04755	600 WORLD WAY SPACE  652	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM			PC Info Complete	02/10/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, PC FOR ENERGY ONLY. TI TO A RETAIL AT THE LAX AIRPORT. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 137 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16707	19041-20000-25130	10050 N RUBIO AVE	91343	12	204B137   800	2685021008	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.2534	-118.49571	Plan check for PV roof mounted system install in to existing PV system, Addition system size: 2.68kW DC 2.52KW AC, with 8 PV Modules and 8 microinverters Enphase  IQ7X.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16708	11041-10000-19293	380 W WORLD WAY FAN ROOM-NO.8	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM			PC Info Complete	03/12/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	Renovation and addition to existing Tom Bradley International Terminal building-BRADLEY WEST RENOVATIONS: TO EXISTING MCC-5EZX,ADDING 2 EA 10 HP SF UNITS AS PART OF EDN-027AND CHANGES TO LIGHTING TO CORRIDOR AND CS16-56.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16709	16041-10000-37551	1136 W GAGE AVE	90044	8	105B197  1135	6003032004	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	33.9822	-118.29523	PV1 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER, (10) MODULES AND (1) FRONIUS INVERTER. TOTAL SYSTEM SIZE IS 2.5KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16710	18041-20001-33761	13274 W FIJI WAY Suite 310	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Issued	09/27/2018 12:00:00 AM	ADDRESS	33.97902	-118.43558	Plan check for Title 24 only. Project site is a suite in an exising commercial building. Project scope is a tenant improvement. Total lighting area = 870 sq. ft.Note: Building permit has been issued under 18016-10000-23608*****Previous Work Description*****INSTALLING (1) DEDICATED CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16711	19041-20000-50978	22955 W MARIANO ST	91367	3	171B097   105	2042008070	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.16843	-118.62733	PV1.  Install 23.76 kW DC / 21.40 kW AC roof mounted PV system.  (72) modules with microinverters.Fess $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16712	18041-20000-04871	15757 W PARTHENIA ST	91343	12	195B141   668	2672011039	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.22848	-118.47584	replace existing metal hgalide fixtures with new led fixtures outdoor.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16713	14041-10000-07234	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	33.98173	-118.4029	METHANE MITIGATION PLANS. BUILDING 2 OF 2. ELECTRICAL PLANCHECK  APPLICATION # 13041-10000-35618	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16714	19041-10000-21854	8900 S SEPULVEDA WESTWAY	90045	11	096B165  1019	4122036022	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	33.95589	-118.39806	Energy plan check for a commercial T.I  (CVS Pharmacy) located in a commercial building. Scope includes new lighting and equipment with a total area of  700-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16715	13041-10000-31617	1140 S LA BREA AVE	90019	10	132B181  1049	5084011016	C2-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.05475	-118.34356	pc for energy. permit to be pulled at EPC counter only. emergency lights and 1story. TI (E) building with new electrical PS due to fire damage. less than >=400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16716	15041-20000-39373	10250 N DEERFIELD LANE	91324	12	204B117   212	2729027054	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.25693	-118.55235	Install a roof mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 15.4kW (2 - 7.7kW inverters). Ungrounded system. (52) 327W pv modules.***Permit Fees zero dollar per 2012 State Senate Bill 1222***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16717	10041-20000-24891	555 W 5TH ST 2nd Floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	02/16/2011 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I. to existing high rise building.  Install general/emergency lighting in mailing area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16718	15041-10001-27825	4319 N SALTILLO ST	91364	3	165A107    26	2172012060	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM			PC Approved	08/29/2015 12:00:00 AM	ADDRESS	34.14819	-118.59366	EXPEDITED FEES FOR ROOF MOUNTED SYSTEM, PER APPLICANT. (((PV1, NEW ROOF MOUNTED SOLAR SYSTEM. (22) MODULES AND (1) 6K INVERTER. UNGROUNDED TRANSFORMERLESS INVERTER, SUBMITTAL PER APPLICANT'S REQUEST.   (22) SUNPOWER SPR-E20-327(1) SB6000TL-US-22 240V)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16719	17041-10001-45523	9640 N OWENSMOUTH AVE	91311	12	201B105   205	2746015006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.24548	-118.60221	REVISIONS TO PERMITTED SET OF PLANS-REMOVAL OF PANEL H4 AND INCLUDED PANEL PD AS A SUBPANEL TO PANEL A; NEW LIGHTING FOR DRESSING AND MAKE/UP ROOMS; UPDATED TITLE 24 FORMS; UPDATE AVAILABLE FAULT CURRENT FROM DWP SERVICE REPORT AND RVISED FAULT CURRENT REPORT((((((((PC FOR POWER AND ENERGY; FOR A TI AND CHANGE OF USE FROM WAREHOUSE/OFFICE TO MOTION PICTURE PRODUCTION; SCOPE INCLUDES ADDING NEW SECTION TO EXISTING SERVICE (2500A 277/480)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16720	16041-10000-12349	14811 W JADESTONE DR	91403	4	159B149   238	2278031006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.13414	-118.45735	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 7.6 kWac.  Central inverter system.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16721	10041-10002-14422	6201 W HOLLYWOOD BLVD	90028	13	148-5A189  54	5546031001	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Closed	10/02/2014 12:00:00 AM	ADDRESS	34.1018	-118.32461	PLAN CHECK FOR REVISION TO APPROVED PLAN. REPLACING BUSWAY WITH CABLE TRAYS AND MC CABLES. DWELLING UNIT METERS  ARE NOW LOCATED INSIDE THE UNITS AND TO BE WIRELESS TYPE. REVISIONS TO T24 ENERGY, LOADS, AND CIRCUITS WILL BE SUBMITTED SEPARATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16722	16041-30000-20827	1000 W WILSHIRE BLVD #1500	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for Title 24 only. Project site is a portion of the 15th floor. Project scope is a tenant improvement. Total lighting area = 4,690 sq. ft. Note: Building application has been generated under 16016-10000-13724	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16723	16041-10000-22474	837 N SPRING ST SUITE 103	90012	1	135A215   314	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	PIN	34.06296813	-118.23676788	T.I. FOR SUITE 103, NEW PARTITION WALLS AND BREAK AREA. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16724	19041-20000-50649	1406 W MANCHESTER AVE	90047	8	097-5A195 289	6037015030	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	33.95984	-118.30079	Power and lighting for (E) commercial space tenant improvement.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16725	15041-10000-38192	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	33.96577	-118.42406	"PC FOR ENERGY. INSTALLING 16 LED LIGHT FOR ILLUMINTAING EXISTINGLETTERS ""LMU"" ON BLUFF. REPLACING 4 EXISTING POLE FLIXTURES WITH LED SPOT LIGHTS AT CHAPEL TOTAL AREA 9000 SQ FT ."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16726	19041-20001-36734	5727 N CANOGA AVE BLDG 2	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	10/14/2020 12:00:00 AM	ADDRESS	34.17529	-118.5978	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16727	14041-10000-12563	3311 N OAK GLEN DR	90068	4	159B181   674	2425029023	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.12965	-118.3508	Install roof-mounted solar array interconnect with main pannelSystem size = 3 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16728	13041-10000-22204	5100 N LOUISE AVE	91316	5	171B133   537	2258009014	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.16322	-118.50963	PV1 8.2KWAC 240V MICROINV 2STORY. STD. ROOFMOUNT.[( 38) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: mitsubishi electric/PV-MLE260HD]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16729	12041-10000-15022	330 N ALVARADO ST	90026	13	136-5A205  46	5157022012	C2-1	Central	Westlake	Greater Echo Park Elysian		2084.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.07002	-118.26798	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR IMPROVEMENTS TO EL POLLO LOCO RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16730	17041-20000-29246	8451-8457 W BLACKBURN AVE	90048	5	138B173   865	5511032013	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			09/13/2017 12:00:00 AM			PC Info Complete	10/31/2018 12:00:00 AM	ADDRESS	34.07239	-118.37503	Plan check for power and energy. Project site is a new 4-story, 18-unit apartment building with a subterranean garage. Work includes a 1,200-amp service and a total lighting area of 18,189 sq. ft. Project is located in a methane zone. Fire alarm variance on file. Note: Building application has been generated under 16010-30000-04749	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16731	14041-20000-20275	20558 W TIARA ST	91367	3	174B109    25	2151018048	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.17699	-118.58155	PV1.  Install 5.355 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16732	13041-20000-33869	14225 W DICKENS ST	91423	4	165B153   468	2266003012	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.14885	-118.44292	NEW 2 STORY + MEZZANINE 18 UNIT TOWN HOUSE BUILDING OVER SEMI-SUBTERANEAN PARKING GARAGE pc for power. and energy for garage level. nonhazardous location. fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16733	16041-10000-21128	1840-1848 W WASHINGTON BLVD	90007	1	126B197   738	5075028003		South Los Angeles				2212.20	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.03977	-118.29864	Full PC. Change of use and remodel existing manufacturing building to commercial kitchen/ catering establishment. (2) services per applicant, 600A 3-phase and 100A 1-phase.  Total area: 9,720 sq.ftB# 15016-30000-27318	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16734	15041-20000-16251	111 W 7TH ST	90014	14	127-5A211  93	5144001011	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.04428	-118.25156	PLANCHECK FOR POWER AND ENERGY. Change of use 1,500 sq ft of 1st floor corner space from retail to dental office & t.i.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16735	18041-10000-30619	20942 W OSBORNE ST	91304	3	195B109    55	2779002005	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.23293	-118.58999	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16736	16041-20000-29548	10831 W CROCKETT ST	91352	2	192B177   712	2407024029	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.22038	-118.36623	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:  3.92 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16737	13041-20000-00728	11513 W ORUM ROAD	90049	5	144B145   188	4369002005	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2013 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.08959	-118.46348	Plan check for 600A panel upgrade. No other changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16738	18041-20000-48513	555 S MATEO ST Bldg 1	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	09/03/2020 12:00:00 AM		Permit Finaled	12/28/2021 12:00:00 AM	ADDRESS	34.03943	-118.23302	Plan check for power and energy for Tenant Improvement office install (2) 800A, (1) 600A distribution as associated load . Total area; 57,940 sq ft.B#15014-10000-02018	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16739	18041-10000-07043	21310 W NORDHOFF ST	91311	3	195B105    17	2779017013	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.23523	-118.59566	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 35950 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16740	13041-10000-29975	19745 W LASSEN ST	91311	12	201B117    88	2726004020	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.25014	-118.56388	PV1, ROOF-MOUNTED MICROINVERTER SOLAR ARRAY INSTALLATION INTERCONNECTING WITH EXISTING 200A MAIN. SYSTEM SIZE IS 7.560 KW AC, WITH 35 MODULES (CANADIAN SOLAR CS6P-250P) AND 35 ENPHASE M215 MICROINVERTERS. 100A LOAD CNETER WILL BE USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16741	14041-20000-03304	8211 W 3RD ST	90048	5	138B173   830	5511019034	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.07264	-118.36846	600A SERVICE UPGRADE AND NEW LOAD FOR CHANGE OF USE TO HAIR SALON. PLAN CHECK FOR POWER AND ENERGY. PLAN CHECK IN ACCORDANCE TO 2008 NEC PER BUILDING SUBMITTAL)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16742	14041-10000-25472	1860 N VINE ST	90028	13	150A189   219	5546033020	[Q]R5-2	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.10488	-118.32652	"0$ fees due to senate bill 1222 from 2012PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 36.456 DC. CENTRAL INVERTER SYSTEM.(143) HANWHA MODUESL(2) FRONIUS 1G 11.4-3(1) FRINOUS IG 10.0-3 ""COMPLY WITH DEPARTMENT ORDER effective date07/25/2005. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16743	19041-20000-04769	5916 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Hermon		1837.02	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.10506	-118.1842	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from take-out restaurant to restaurant/tenant improvement. Total lighting area = 855 sq. ft.Note: Building application has been generated under 18016-10000-41014	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16744	19041-10000-14108	15140 W BLEDSOE ST	91342	7	222B145   103	2506002029	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	05/20/2020 12:00:00 AM		Permit Finaled	08/26/2021 12:00:00 AM	ADDRESS	34.30714	-118.46302	NOTE: FEES ARE $0 DUE TO AB 1414. PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 324 MODULES / 162 OPTIMIZERS ) AND 1 INVERTERS ( SE 99.9K). SYSTEM SIZE IS 100KWac AND 129.36KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16745	13041-10000-08989	3930 N VALLEY MEADOW ROAD	91436	5	162B141    94	2286017019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.14213	-118.47889	PV1 ROOF MOUNTED PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING. SYSTEM SIZE IS 22.25 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16746	16041-10001-16398	1520-1522 E PACIFIC COAST HWY	90744	15	036B213   501	7425023014	[Q]C1-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM			PC Approved	06/17/2016 12:00:00 AM	ADDRESS	33.79093	-118.24476	Ti for existing office space - title 24 indoor and outdoor lighting total area = 4404 sq. ft.Permit was pulled under pcis: 16041-40000-16398/plan check #: X16sp01677. REMODEL/TENANT IMPROVEMENT OF EXISTING SINGLES STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16747	12041-20000-30862	3470 S TROUSDALE PKWY	90089	8	120A201    75	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM	05/06/2013 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.02202	-118.28393	Plan check for service upgrade. Fees per applicant. Lighting is to remain as is. WAITE PHILLIPS HALL OF EDUCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16748	13041-20001-34020	19771 W BUCKEYE MEADOW LANE	91326	12	213B113   226	2701029024	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM			PC Approved	12/27/2013 12:00:00 AM	ADDRESS	34.28087	-118.56665	((Expedite fees))PV1 LF TRANSFORMER WITH MICROINVERTER. TOTAL SYSTEM SIZE 7.2KW. 30 PANELS 1 INVERTER AND 4 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16749	17041-10000-41641	2301 N HOBART BLVD	90027	4	153B193   211	5588001023	RE11-1	Central	Hollywood	Hollywood United, Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.1137	-118.30542	PC for rooftop solar for 10.05kW PV system. Installing 30 new AC modules with 125A load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16750	14041-20000-12121	6800 S AVALON BLVD	90001	9	102B205   234	6007019019	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Closed	10/30/2020 12:00:00 AM	PIN	33.97787513	-118.26444398	"PLANCHECK FOR POWER AND ENERGY FOR A NEW ADDITION TO AN EXISTING BUILDING. NEW 1200AMP SERVICE. BUILDING PERMIT FOR THE THE ADDITION: 10014-10000-03104: Addition of one story 153'-7"" x 102' warehouse shell bldg. with accesory office/restrooms to (E)warehouse .  Restripe parking lot.  SEE COMMENTS.  ""Comply with dept. order dated 5/26/08.  This permit will expire in 30 days from issuance date."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16751	15041-10005-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM			PC Approved	04/12/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Supplementary PC for change in Fire pump fuse from 400 A to 300A, changing transfer switch frim 65KAIC to 50KAIC, and two breakers from 600 to 800 A and 400 to 600 A.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16752	18041-10000-10871	1965 N HILLHURST AVE	90027	4	150B197   560	5590012045	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.10719	-118.28759	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16753	16041-10000-29360	2730 W OLYMPIC BLVD	90006	10	129B197   355	5078011024	C2-1, P-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.05244	-118.29287	T-24, PC FOR ENERGY ONLY. TI, CHANGE OF USE FROM RETAIL TO BANK. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1400 SQ. FT. B#16016-30000-18818	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16754	18041-10000-45385	3540 E PICO BLVD	90023	14	118-5A225 309	5191021008	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.01791	-118.20147	PLAN CHECK FOR POWER AND ENERGY ADDING 2 NEW PANELS ON MAIN EXISTING SWITCH BOARD OF 600AMP. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING SYSTEM. TOTAL EFFECTED AREA 2967 SQFT. NEW CONNECTED LOAD OVER 400 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16755	14041-10000-23743	1149 S HILL ST	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.03926	-118.26099	Title 24 Plan check for a commercial TI on a 7th floor of a highrise building. total area is 1488 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16756	11041-20001-00556	12366 N MONTERO AVE	91342	7	219B161   271	2525027014	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM			PC Approved	03/01/2011 12:00:00 AM	ADDRESS	34.29458	-118.40886	Plan check only. Delta 1 revision to approved plans T24 calculation and floor plan layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16757	13041-10000-35675	5835 N DONNA AVE	91356	3	174B121   777	2156012036	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.17647	-118.54771	PV1, Install 13.75 kW DC roof-mounted solar array for a 3 story house, interconnect with main service panel. (1) inverter: Fronius IG Plus V 11.4. (55) modules: Hanwha HSL60P6-PB-4-250TW. ==> ZERO Permit fee due to the PV fee ordinance.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16758	18041-20000-01112	3715 S MCCLINTOCK AVE Suite 222B	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.02041	-118.29027	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 435 sq. ft.Note: Building application has been generated under 17016-10000-34393	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16759	18041-20000-18520	14838 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.29479	-118.45438	PV1.  Install 3.78 kW roof mounted grid tied PV system.  (12) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16760	14041-10000-00404	10363 N BALBOA BLVD	91316	12	204B133    62	2695020024	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	PIN	34.25890844	-118.50301264	Alteration of existing retail space ~2500 sq ft.  Title 24 plan check only for changes to lighting system.  Permit to be issued at electrical plan check coutner.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16761	18041-20003-22619	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM			PC Approved	10/25/2018 12:00:00 AM	ADDRESS	34.1937	-118.49152	10-25-2018, changes include relocate transformer, disconnect and performance meter. Changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16762	15041-20000-16287	936 S OLIVE ST UNIT 353	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #7 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16763	14041-10000-09251	721 E 12TH ST #10	90021	14	124-5A211 307	5132012106	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.03348	-118.25258	Remove HID light fixtures and replace with new fluorescent fixtures. Total area 390 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16764	18041-30000-19270	13160 W MINDANAO WAY #184	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM			Corrections Issued	05/23/2018 12:00:00 AM	ADDRESS	33.98501	-118.43726	**medical office space*** This is plan check only for T24 on TI Ste. 184. Total area: 1,251 sq.ft<<Permit was obtained under 18041-30000-17760, which includes: (25) NEW RECEPTACLES(10) NEW SWITCHESRELOCATING (4) EXISTING FIXTURES>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16765	16041-10000-19282	2001 W BEVERLY BLVD	90057	13	136-5A205 384	5157026002	C2-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.06623	-118.2689	PV2 INSTALL 5.220 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING(18) MODULES: TRIEX U290 BLACK (1) INVERTER: SOLAREDGE SE5000-US-240USES POWER OPTIMIZERS	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16766	19041-10000-12471	4060 W WASHINGTON BLVD	90018	10	126B185   996	5060008004	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.01	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Issued	05/29/2019 12:00:00 AM	ADDRESS	34.03968	-118.32772	PC FOR POWER AND ENERGY FOR TENANT IMPROVEMENT AT EXISTING RETAIL/GROCERY STORE. SCOPE INCLUDES NEW 1600A  DIST. NEW PANEL, CIRCUITS, EQUIPMENT AND  LIGHTS.TOTAL AFFECTED AREA  23597 SQ.FT B#19016-10000-09547	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16767	14041-20000-03791	7300 N SYLVIA AVE	91335	3	186B117   869	2104029022	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.20311	-118.5523	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL. 4 kW SYSTEM IS TRANSFORMERLESS, WITH (16) MODULES, CANADIAN SOLAR CS6P-250P (8 PER STRING, 2 TOTAL STRING), (1) 3.6 POWERONE  PVI-3.6-OUTD-US-A  INVERTER (AFCI CAPABILITY).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16768	16041-20000-10401	10944 W VENTURA BLVD	91604	2	162B173   609	2378007006	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.13979	-118.36893	Fire alarm plan check only. Install a new FACP and 23 devices in 2-story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16769	12041-20000-06631	900 S FIGUEROA ST lobby	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.04604	-118.26272	energy plan check lobby	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16770	15041-20001-34579	6250 N TOPANGA CANYON BLVD Ste.1380	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM			PC Approved	04/08/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	04/08/2016 Changes to an approved set of plans. Changes have been made to the lighting layout, power layout, and elevator location. All changes have beeb clouded and marked as Delta 5. *****Previous Work Description*****PLANCHECK FOR POWER AND  ENERGY.  TI IN RETAIL MALL . NEW TOTAL WINE AND MORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16771	19041-20000-07498	5639 E RABER ST	90042	14	157-5A227 105	5480033005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.12671	-118.19518	PLAN CHECK FOR ROOF MOUTNED ADDITION TO EXISTING GROUND MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM ADDITION SIZE IS  4.81 KW DC/3.8 KW AC. SCOPE OF WORK INCLUDES (13) SILFAB SOLAR SLG-M 370 PV MODULES, (1) SE3800H-US 240V INVERTER, AND (1) NEW 100A SOLAR LOAD CENTER. MCB DERATE FROM 200A TO 175A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16772	13041-10000-33353	1256 W 7TH ST	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.05216	-118.26774	FA PANEL REPLACEMENT AND ANN for a hotel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16773	11041-10000-03117	6000 N VAN NUYS BLVD	91401	6	177A151    91	2240007901	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Expired	07/30/2013 12:00:00 AM	ADDRESS	34.17979	-118.44842	PV SYSTEM ON ROOF OF EXISTING OF SINGLE STORY COMERCIAL BUILDING.  30 KW SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16774	14041-10000-14402	806 W 145TH ST	90247	15	075B197   321	6119020022	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	33.90027	-118.28964	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16775	13041-10001-29547	1933 S BUNDY DR bldg # 3	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			PC Approved	05/02/2014 12:00:00 AM	ADDRESS	34.0344	-118.45642	((5/2/2014- CHANGES MADE TO APPROVED SET. RELOCATION OF FACP AND REMOVED SOME DEVICES. THIS IS A PLAN CHECK ONLY APPLICATION))Installation of a new fire alarm system and to provide 24-hour system monitoring to sprinkler system.  One-story commercial shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16776	12041-10001-21937	11136 N PROVENCE LANE PV1	91042	7	210B197   543	2552048030	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2012 12:00:00 AM			PC Approved	10/25/2012 12:00:00 AM	ADDRESS	34.27177	-118.29169	PLAN CHECK FOR 6.48KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING TRANSFORMERLESS INVERTER. EXISITNG PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16777	19041-20000-32299	8422 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16778	14041-20000-10715	444 S FLOWER ST 9TH FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY, <400 NEWLY CONNECTED AMPS. 11955 SQFT, EMERGENCY LIGHTING. HIGHRISE . 9TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16779	18041-20000-23485	20950 W AVENUE SAN LUIS	91364	3	171B109   166	2167020026	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.16472	-118.59013	Plan check for PV roof mounted system, system size: 10.4kWdc/8.67kW AC CEC with 29 modules and 2 inverters(5.2kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16780	11041-20000-16852	13207 N GLADSTONE AVE B	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	09/28/2011 12:00:00 AM	ADDRESS	34.31086	-118.4288	Plan check T24 Energy for bakery space TI in an existing grocery store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16781	17041-20001-11832	17075 W DEVONSHIRE ST	91325	12	204B133   139	2695020031	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	34.2577	-118.50483	expeditepv2install roof mounted pv system sized 57.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16782	19041-20000-03661	2500 W WILSHIRE BLVD	90057	1	133-5A201 152	5141007001	C4-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	04/10/2023 12:00:00 AM	ADDRESS	34.06002	-118.28081	Plan check for power and energy. Project site is an existing 13-story commercial building. Project scope is an adaptive reuse conversion from office to mixed-use residential. Residential consists of (248) units. Service and service equipment is existing. Distribution panels, subpanels, and loads are new. Total lighting area = 27,385 sq. ft.Note: Building permit has been issued under 15016-10000-15343	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16783	14041-20000-18194	9828 N CREBS AVE	91324	12	201B121   211	2763022015	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.24907	-118.54443	New Roof mounted PV system with total system size 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16784	16041-10002-30699	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	33.97811	-118.39245	DELTA 22 CHANGES TO THE APPROVED PLANS. PLANCHECK ONLY. SCOPE OF WORK INCLUDES THE RELOCATION OF EQUIPMENT AND EXTENSION OF A CIRCUIT FOR A FIRE DAMPER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16785	13041-20000-04957	1817 W 41ST DR PV-1	90062	8	114B193   589	5022002004	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Expired	03/26/2015 12:00:00 AM	ADDRESS	34.00915	-118.31192	PV-1. MIcroinverter standard plan. 6.0kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16786	18041-20000-44072	8846 N LANGDON AVE pv1	91343	6	195B145   309	2654013027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.23143	-118.46968	pv1install roof mounted pv system sized 9.1KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16787	16041-20001-36547	14401 W SYLVAN ST	91401	6	178-5A151 121	2240002015	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM			PC Approved	12/12/2016 12:00:00 AM	ADDRESS	34.1848	-118.44665	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 30 kWac and consists of (3) inverters, (96) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16788	13041-10000-35007	21701 W VENTURA BLVD	91367	3	174B105    62	2168027030	(T)(Q)C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM	PIN	34.16899731	-118.60037995	NOTE:tHER WAS NO NEED O SUBMITY THIS SINCE THIS FOR CAR WASH ONLY , DONE BY A SEPERATE CONTARCTOR.PLAN CHECK FOR POWER AND ENERGY FOR WASH RACK BUILDING. BUILDING 2 OF 2. FEES CALCULATED ON PC # 13041-10000-35003. BUILDING PERMIT # 13010-10000-04092 , 13010-10000-04089	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16789	19041-10000-45793	4448 N EAGLE ROCK BLVD	90041	14	157-5A221 199	5474008008	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Public Safety Only			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.12546	-118.21926	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16790	14041-20002-17736	124 S CROFT AVE	90048	5	138B173   687	5511014007	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.07387	-118.37406	Recheck of lost set of plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16791	19041-10000-48952	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	12/09/2022 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR A NEW CONSTRUCTION ( NEW GROUND UP MALL EXTENSION), SCOPE OF WORK INCLUDES TWO NEW 4000A SERICES (480/277 3P,4W)  THAT FEEDS VARIOUS ELECTRICAL DISTRIBUTION EQUIPMENT THAT FEEDS VARIOUS HOUSE PANELS AND VARIOUS HVAC EQUIPMENT. THE SINGLE LINE ALSO SHOWS A 350KW EMERGENCY GENERATOR, TOTAL AFFECTED AREA IS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16792	17041-20005-45582	16633 W OAK VIEW DR	91436	5	168B137   395	2289020013	R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Issued	06/12/2018 12:00:00 AM	ADDRESS	34.15694	-118.49746	06/12/2018 Changes to an approved set of plans. All changes have been clouded. Equipment has been relocated. There has been an addition of a load center.05/01/2018 Changes to an approved set of plans. All changes have been clouded. Electrical equipment has been relocated to match field installation.*****Previous Work Description*****Revisions to approved set. Relocation of equipment.  $0 plan check fee per State Senate Bill SB 1222.02/28/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the configuration of system interconnection.*****Previous Work Description*****Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(36) 300W pv modules. (2) 5kW Tesla Powerwall 2s.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16793	10041-20000-24991	19851 W NORDHOFF PL	91311	12	198B113   150	2761001081	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Expired	01/02/2013 12:00:00 AM	ADDRESS	34.23624	-118.56649	office energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16794	16041-10000-36803	617 N AVENUE 50	90042	1	151-5A225 168	5469010004	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.10989	-118.20555	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(29)AXITEC AXIPOWER AC-265P/156-60S(1)INVERTER-FRONIUS PRIMO 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16795	13041-10001-33183			4	135B185    14	5515013001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	PIN	34.07003496	-118.32688209	"((3/5/2015)) CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 4 ON THE PLANS.  CHANGES INCLUDE REVISED ENERGY CALCULATIONS FOR ADDED AREA (RESTROOMS).((3/5/2015))MASTER PERMIT IS NOT PULLED.  DO NOT RELEASE UNTIL MASTER PERMIT IS PULLED.plan check for power and energy. NEW BUILDING ON CAMPUS OF A PRIVATE GIRLS HS (NEW 129'-4"" x 157'-8""1 story AQUATICS PAVILION BUILDING WITH BASEMENT STORAGE AND ATHLETICS FITNESS ROOMS). methane zone. Also LARGER SURFACE PARKING LOT, A NEW GARDEN AREA, A FULL-SIZE SYNTHETIC TURF SOCCER FIELD, AND 3 NEW TENNIS COURTS. Changes on plan include battery on exit sign to also be fed by inverter and panel FP bus is 125A. Pool panel ACPL installed but loads to be added under separate permit.Fire alarm variance  filed on 8/20/2014"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16796	15041-20000-36951	6600 N TOPANGA CANYON BLVD 9000	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/03/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24. PC FOR ENERGY ONLY. SCOPE INCLUDES INSTALLATION OF A KIOSK IN AN INDOOR MALL. TOTAL AREA IS 300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16797	19041-10000-47502	1122 S WALL ST	90015	14	124-5A209 125	5145024031	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.03582	-118.25452	REMOVE HID FIXTURES AND RAPLCE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16798	18041-10000-06108	21333 W DEERING CT	91304	3	189B105   146	2109001021	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Issued	02/20/2018 12:00:00 AM	ADDRESS	34.21622	-118.59629	REPLACE INDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16799	16041-20000-29103	8544-8654 N WINNETKA AVE	91306	3	192B113   737	2782011044	(Q)R1-1, (Q)RD4-1XL	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.22581	-118.57084	Plan check for outdoor lighting for a new tract home community. Total lighting area =65,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16800	19041-20000-42354	11940 N MIRABEL WAY	91326	12	216B109   178	2701081027	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	02/25/2021 12:00:00 AM	ADDRESS	34.29005	-118.58193	PV1. INSTALL 5.25 KW DC PV SYSTEM WITH (15) MODULES/MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16801	15041-20000-36899	920 W DOWNEY WAY SUITE B12	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/03/2015 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	ADDRESS	34.02063	-118.28879	T-24 ONLY. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (LAB/OFFICE SPACE FOR USC). SCOPE INCLUDES RELOCATING PANEL PBA AND ADDING NEW LIGHTING TO LAB AND OFFICE. TOTAL AREA IS 699 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16802	14041-10000-16535	707 W WILSHIRE BLVD	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 40TH FLOOR. HIGH RISE. 15046 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16803	13041-10000-36113	650 S HIGHLAND AVE PV1	90005	4	135B185   495	5507018009	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	05/01/2014 12:00:00 AM	PIN	34.06344135	-118.33811132	PV1, ROOF-MOUNTED SOLAR ARRAY INTERCONNECTING WITH 400A MAIN SERVICE. MICROINVERTER SYSTEM ON NON-STANDARD PLAN; (42) MODULES, (1) SOLAR LOAD CENTER, (42) ENPHASE M215 MICROINVERTER.NOTE: PAID ON 12/31/2013;  QUALIFIES FOR 2008 NEC EDITION	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16804	18041-10000-15398	5560 W ADAMS BLVD	90016	10	123B177  1042	5048029006	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.03231	-118.36434	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 600A SERVICE/DISTRIBUTION BOARD, NEW PANELBOARDS, AND NEW LIGHTS FOR A CORE & SHELL BUILDING.  TOTAL AFFECTED AREA IS 2113 SQ. FT. BLDG PERMIT # 18016-30000-12244	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16805	19041-10000-22451	1419 W COLTON ST	90026	1	135A209   172	5160012909	CW	Central	Westlake	Echo Park	YES	2080.00	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Issued	06/12/2019 12:00:00 AM	ADDRESS	34.06424	-118.25931	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 50 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16806	12041-20000-14278	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			Plans on Hold	03/07/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	Changes from previously approved plans.  Bulletin 215 Only .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16807	15041-20001-10050	12460 W OSPREY LANE unit# 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	Expedite per applicant request(((Plan check for PV roof mounted system for tri-plex unit #3 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10046)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16808	14041-20000-35979	1939 N WESTRIDGE TER	90049	11	138B133   466	4492012018	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.0708	-118.5007	"""0$ permit fees due to senate bill 1222""PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2KW INTERCONNECTED WITH MSP.(50) HYUNDAI HIS-M250MG MODULES(2) ABB PVI-4.2/6000 INVERTERS"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16809	10041-20001-22254	20301 W VENTURA BLVD SUITE 105-SUITE 105A	91367	3	174B113   515	2166033040	(Q)C4-1LD, (Q)P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM			PC Approved	12/09/2010 12:00:00 AM	PIN	34.16986681	-118.57545146	PLAN CHECK ONLY. T24 ENERGY GENERAL LIGHTING FOR OFFICE T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16810	18041-10000-37153	20929 W VENTURA BLVD UNIT 32	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	new panel and ckts in exisiting retail spacePLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16811	10041-20000-21075	1207 S VERMONT AVE	90006	1	129B197   797	5078028004	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			10/22/2010 12:00:00 AM			PC Info Complete	01/13/2011 12:00:00 AM	ADDRESS	34.04886	-118.29184	Install new emergency generator system. Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16812	14041-20000-24890	8974 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.23326	-118.55337	TI TO AN EXISTING COMMERCIAL BUILDING ONE STORY.  SWITCHING LIGHTING, EXISTING PANELS NO NEW LOADS.  2128 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16813	17041-10000-03126	2049 S CENTURY PARK EAST 14TH FLR-L-OBBY	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY. INTERIOR RENOVATION IN 14TH FLOOR LOBBY. AFFECTED AREA 1915 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16814	11041-20000-19418	2619 W WILSHIRE BLVD	90057	1	133-5A201  70	5141009015	C4-2	Central	Westlake	MacArthur Park	YES	2087.20	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM			PC Approved	09/13/2011 12:00:00 AM	ADDRESS	34.06097	-118.28196	Revision to approved plans #10041-20000-00329. Relocate existing fire pump disconnect switch to a different 1hr rated room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16815	15041-20001-16272	936 S OLIVE ST UNIT 255	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #4 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259.PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16816	15041-10000-33079	2510 S FIGUEROA ST STE-H	90007	9	121-5A203  24	5124027017	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.02877	-118.27529	Energy plan check for a retail (T-mobile) T.I. Scope includes new lighting and receptacles; Total area is 1568-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16817	18041-20000-43427	5245 W SANTA MONICA BLVD	90029	13	144B193   695	5537009036	C2-1D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Closed	08/08/2023 12:00:00 AM	ADDRESS	34.09094	-118.30401	PV3.  Install 14.4 kW roof mounted grid tied PV system connecting to (E) 3000A 208Y/120V 3ph-4w service.  (40) modules with 14.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16818	15041-10000-18703	1925 S CENTURY PARK EAST ste 450	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	pc for energy.  Alteration to an exisiting office and corridore. Hi rise. Total area 779 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16819	10041-30001-03440	602-604 S HAMPTON DR	90291	11	109-5A143 108	4286007001	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM			PC Approved	03/11/2010 12:00:00 AM	ADDRESS	33.99491	-118.47521	PLAN CHECK ONLY. PLAN CHECK FOR T-24 GENERAL/EMERGENCY  LIGHTING.  PERMIT IS ON PREVIOUS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16820	11041-10001-09106	2403 E 1ST ST	90033	14	127-5A223 160	5180002017	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM			PC Approved	08/10/2011 12:00:00 AM	ADDRESS	34.0437	-118.2094	Modification to an approved set of plans.  Modifying an 18 W fixture down to a 13 W fixture.  Plan check is for energy only.  <<<<<TI TO AN EXISTING RESTAURANT.  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK ONLY FOR EXPIRED PLAN CHECK.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16821	18041-30000-18497	15330 W ANTIOCH ST	90272	11	129B125   615	4412003004	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Issued	05/17/2018 12:00:00 AM	ADDRESS	34.04698	-118.52697	Energy plan check for an office T.I. Scope includes new lighting and equipment. Total area is 806-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16822	13041-10000-23373	4018-4022 S BROADWAY PL	90037	9	115-5A203 203	5111025019	M1-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.01052	-118.27754	Plan check power and energy for tenant improvement for new laundry and market in existing single story building. Change of use to building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16823	18041-10001-07709	8913 W 25TH ST	90034	10	126B169  1229	4302015022	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.03864	-118.3858	EXPEDITE PER AAPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16824	16041-10000-21845	400 W WESTMONT DR	90731	15	024B201   348	7412026017	[Q]M3-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	33.7641	-118.28532	PV2.  3.735 mega watts roof-mounted system with 13,005 modules, and 45 Delta inverter interconnecting through the utility transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16825	17041-10001-42316	5300 W ADAMS BLVD	90016	10	123B177  1014	5043006001	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/25/2024 12:00:00 AM	ADDRESS	34.03224	-118.35886	CHANGES ON APPROVED SET. ADDRESS DELTA 1 CHANGES. CHANGES INCLUDE RELOCATION OF THE SWITCHBOARD, ADDING 2 FUTURE EV CHARGERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16826	13041-10000-06587	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	"T24 PLAN CHECK FOR RETAIL SPACE AT THE BEVERLY CENTER #640 ""SEE EYEWEAR"". 1040 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16827	14041-10000-19813	1630 N SAN PABLO ST	90033	14	135A225    11	5202001004	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.06498	-118.20218	PLANCHECK FOR POWER AND ENERGY. NEW TYPE IB 5 STORY/ 6 LEVEL  PARKING STRUCTURE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16828	19041-10000-44795	3338 N THELMA AVE	90032	14	142-5A233 233	5213015039	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.08468	-118.17898	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US), 11 MODULES AND P320 OPTIMIZERS CONNECTED TO EXISTING 100A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16829	18041-10000-22929	801 S OLIVE ST Suite B	90014	14	127-5A209  31	5144019026	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.04514	-118.25715	FULL PLAN CHECK FOR FIRST TIME TENANT (N) RESTAURANT IN CORE & SHELL. CONNECTED LOAD IS APPROX 400A USING EXISTING DISTRIBUTION BOARD WITH NEW SUB-PANELS. TOTAL AFFECTED AREA = 4347 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16830	18041-20000-40488	11668 W OLYMPIC BLVD 1-6	90064	11	123B149   388	4260013029	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	09/09/2022 12:00:00 AM	ADDRESS	34.03434	-118.44735	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new shell building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16831	13041-20001-34557	3304 W BELLEVUE AVE	90026	13	141A201   380	5401013017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	34.07875	-118.2804	EXPEDITE FEES ONLY.           <<New rooftop pv system for an existing sfr.  System uses DC-DC converters and is UNGROUNDED.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16832	10041-20000-21389	333 S HOPE ST	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	12/30/2010 12:00:00 AM	ADDRESS	34.05326	-118.25292	energy plan check 26th floor lobby and coridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16833	15041-10000-28006	12208 W RIVERSIDE DR	91607	2	168B165   552	2356036035	RD1.5-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.15736	-118.399	New 8 unit aparment bldg pc for power and energy. 1000 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16834	14041-20001-25452	21301 W BURBANK BLVD 3RD FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	34.17351	-118.59524	11/12/2014 - Plan check for modifications to approved set. Re-plan check Title 24 since fixture types and fixture counts have changed. Also some additional dimmer switches. Changes clouded on plan.[TI FOR FULL 3RD FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16835	14041-20000-14167	13976 W POLK ST	91342	7	228B153   636	2504021037	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.31794	-118.43788	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 9kW(1) Power-One  # Aurora PVI-6000-OUTD-US-Z-A transformerless inverter(1) Power-One  # Aurora PVI-3.0-OUTD-S-US-Z-A transformerless inverter(41) Canadian Solar #CS6P-250PX pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16836	11041-10000-24017	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Closed	02/25/2014 12:00:00 AM	ADDRESS	34.14246	-118.2705	New Switchboards and M.C. panels for a water treatment plant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16837	11041-10000-23042	1300 N VERMONT AVE 7TH FLOOR	90027	13	147B197   892	5542017***	C2-CSA1	Central	Hollywood	East Hollywood		1913.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.09579	-118.29152	TI ON THE 7TH FLOOR OF AN EXSTING MEDICAL BUILDING. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16838	19041-20000-38908	1110 S SPAULDING AVE 1-26	90019	10	132B177  1028	5085024020	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			09/27/2019 12:00:00 AM	03/13/2023 12:00:00 AM		Permit Closed	03/12/2024 12:00:00 AM	ADDRESS	34.05564	-118.36007	Plan check for Power and energy for 26 units multi-family 6 story low rise building. Service size: 1200A 120/208 Volts 3phTotal area: 31,221 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16839	19041-20000-32654	11272 W NEBRASKA AVE 1-24	90025	11	126B149   264	4261020002	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.04399	-118.44584	Plan check for for new fire alarm system, new fire alarm devices: 90 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16840	17041-10000-38799	7007 W ROMAINE ST	90038	4	144B181   604	5532030011	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.08901	-118.34188	PLAN CHECK FOR T24 ONLY, 1 LEVEL SUBTERRANEAN PARKING GARAGE ADDITION WITH SURFACE PARKING TO EXISTING 6-STORY MEDIA PRODUCTION BUILDING. NEW ADDITIONAL LOAD < 200A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16841	15041-10000-14901	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	PLAN CHECK FOR POWER AND ENERGY FOR NEW GYM IN EXISTING MALL. 800A DISTRIBUTION FOR GYM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16842	15041-20000-00091	12200 W OLYMPIC BLVD Suite 400	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.03195	-118.45506	Plan check for energy only. TI to private offices on 4th floor of high rise office building. New lighting and receptacles. 1,036sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16843	13041-10000-07983	1055 W 7TH ST Floor 18	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.0507	-118.26334	T24 for high rise office space. Moving more than 50% of luminaires. Total sqrft: 3732. Permit to be pulled at electrical plan check counter only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16844	18041-20001-14617	115 W 59TH PL	90003	9	105B201   283	6005012018	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	33.98616	-118.27454	Expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16845	13041-10000-21394	624 S GRAND AVE 19TH FLOOR	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	REPLACEMENT OF EXISTING EQUIPMENT WITH NEW EQUIPMENT IN A HIGH-RISE BUILDING (30 STORIES) . WORK DONE IS ON THE 19TH FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16846	18041-10000-46021	9126 W CORDELL DR	90069	4	144B169   216	5560014018	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2018 12:00:00 AM			PC Info Complete	03/06/2019 12:00:00 AM	ADDRESS	34.09358	-118.39118	NEW 3 LEVEL, 12,000 SQR FT SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16847	15041-30000-39233	12050 W GUERIN ST	91604	2	165B165  1299	2368003***	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.14612	-118.39413	Replacement of fire alarm control panel in existing fire alarm system.  Original fire alarm control panel was subject to fire damage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16848	12041-20000-21807	5805 N SEPULVEDA BLVD #620	91411	2	174B145   102	2243001009	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.17593	-118.46647	TENANT IMPROVEMENT TO CONSTRUCT NON-BEARING OFFICE PARTITIONS WITHIN SUITE #620 (APPROX. 2337 SF).  New lighting and receptacles in empty office space.  Load is less than 400A per applicant.  PLAN CHECK ONLY for Energy, with No Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16849	10041-20000-25659	401 S RAMPART BLVD	90057	1	135A203   129	5155021006	R4-1	Central	Westlake	Rampart Village	YES	2087.20	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			Corrections Issued	02/13/2011 12:00:00 AM	ADDRESS	34.06494	-118.27998	Plan check new roof mounted 16.92 Photovoltaic System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16850	19041-20001-03754	19139 W STRATHERN ST pv1	91335	3	189B121   167	2104003027	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.21574	-118.55074	expeditepv1install roof mounted pv system sized 11.4KW interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16851	11041-20000-20079	1717 N GARFIELD PL 1-120	90028	4	148-5A193  97	5544003003	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			09/21/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.10227	-118.31103	apartments building new fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16852	16041-10000-44985	10201 W PICO BLVD BLDG 103/-FLR 4	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	FULL PC TI ON 4TH FLOOR. BUILDOUT OF OFFICE SPACES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16853	12041-10001-06759	10377 W MCBROOM ST	91040	7	207B177   104	2528031014	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2012 12:00:00 AM			PC Approved	09/25/2012 12:00:00 AM	ADDRESS	34.26281	-118.35664	REVISION TO APPROVED PLANS. CHANGE ONE INVERTER AND CALCULATIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16854	12041-20000-31140	8232-8254 N WHITE OAK AVE # 1 to # 5	91325	12	192B129   323	2201001032	(Q)C2-1VL, C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1154.01, 1312.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.22023	-118.51841	Replace meter section, install new conduits and panels, provide exterior lighting for remodeled building.  Plan check for electrical and exterior lighting.  Tenant work to be done on separate plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16855	17041-20000-00958	9010 N FORBES AVE	91343	12	195B133    73	2688025039	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.23422	-118.4998	Plan check for an addition of a PV1 roof-mounted PV system onto an existing PV system. System addition size is 11 kWac for a total system size of  12 kWac. Additon consists of (51) modules, (51) micro-inverters, and (1) load center.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16856	18041-10000-41198	2417 E 24TH ST	90058	14	117A217    18	5168019009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.01638	-118.22935	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16857	17041-20000-22505	2737 N CHADWICK CIR	90032	14	141A233   255	5217004022	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.07933	-118.17608	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.72 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16858	18041-10000-25250	10757 W PALMS BLVD	90034	5	120B161   854	4254026016	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			07/06/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/09/2020 12:00:00 AM	ADDRESS	34.02397	-118.41335	PC FOR POWER AND ENERGY NEW 14 UNIT APARTMENT BUILDING. SCOPE INCLUDES NEW SERVICE  600A 120/240V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16859	16041-10000-16902	22631 W VENTURA BLVD	91364	3	171B097   166	2040028010	C1.5-1VLD, C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.16734	-118.6201	TITLE 24 PC. 597SQFT  ADDING NEW TRANSFORMER AND PANEL. STORAGE AND COOLER LIGHTING AND EQUIPMENT  T.I. to (e) market (Smart & Final). Convert portion of sales floor to storage area, new prefab meat cooler and prep room, new chicken oven, new and relocated refrigerated cases, new grease interceptor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16860	17041-20000-32215	6447 N CLEON AVE	91606	2	180B173   741	2414030021	QRD4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.18804	-118.36826	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16861	16041-20000-20307	1999 S AVENUE OF THE STARS 24th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check Title 24 only T.I. in existing space Morgan Stanley. Total area:  1080 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16862	17041-10000-00925	11250 W SANTA MONICA BLVD 1-78	90025	11	129B149   460	4261008022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.04661	-118.44736	PC FOR ENERGY ONLY, T-24, TO AN (E) HOTEL. SCOPE OF WORK ICLUDES NEW LIGHTING  AND RECEPTACLES IN THE LOBBY, FITNESS AND OUTDOOR AREA. TOTAL SQ. FT. 1707.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16863	17041-10001-21476	1100 S GLENDON AVE UNIT 1800	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Issued	06/29/2017 12:00:00 AM	ADDRESS	34.06074	-118.44418	OFFICE TI, THIS APPLICATION IS PC FOR T24 ENERGY ONLY. MASTER PERMIT ISSUED FOR EARLY START. THIS APPLICATION IS CONTINUE CONTRUSTION AND LIGHTING DESIGN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16864	10041-10001-22501	19600 W PLUMMER ST	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			04/15/2011 12:00:00 AM			No Progress	04/17/2012 12:00:00 AM	ADDRESS	34.2426	-118.5602	This plan check was superceded on April 17, 2012 by application number 10041-20003-22501 for which the total permit fee was paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16865	14041-20000-11601	5533 S LONG BEACH AVE	90011	9	108B213   380	5105014031	[T][Q]CM-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Issued	05/15/2014 12:00:00 AM	PIN	33.9919632	-118.24380971	PLANCHECK FOR POWER and energy. UPGRADE OF SERVICE TO 800 AMPS. new circuits and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16866	10041-20000-25103	13275 N GOLDEN STATE RD	91342	7	225B141  1516	2604002059	(Q)M1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	01/12/2012 12:00:00 AM	PIN	34.31226914	-118.48573073	industrial rental facility	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16867	14041-10000-01561	2736 N ARMSTRONG AVE	90039	4	150A207   143	5439023008	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.10596	-118.2662	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with exsisting service panel. (1) Transformerless inverter(s):n Solaredge SE3800A-US-ZB-U. (18) Modules TRINA SOLAR TSM-250PA05.18.(18) Optimizer:SOLAREDGE P300-2NA4AZS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16868	12041-10000-12993	1042 W DOWNEY WAY	90089	8	117B197     6	5039002034	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.02169	-118.29124	T.I. to an existing USC Laboratory/Office on the 3rd floor, basement, and roof.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16869	13041-10000-30820	3430 S VETERAN AVE	90034	5	120B161  1003	4254021021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.02302	-118.41839	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 18 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16870	14041-10000-15680	217 N LARCHMONT BLVD	90004	4	138B189   604	5515018015	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.07522	-118.32388	PLANCHECK FOR T24 PER INSPECTORS REQUEST.  TENANT IMPROVEMENT.  RESTAURANT. NO CHANGE IN OCCUPANCY. PERMIT PREVIOUSLY PULLED UNDER 14041-10000-10268. INSPECTOR TO VERIFY FIXTURE AND DESIGN BUILD CONTRACTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16871	13041-20000-09528	3014 S POTOMAC AVE	90016	10	120B181   458	5057020004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.02713	-118.34379	SOLAR SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16872	10041-10000-08956	10500 S SERVICE ROAD	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM			Plans on Hold	07/16/2010 12:00:00 AM	ADDRESS	33.94015	-118.42564	DISCONNECT MAIN SERVICE 4160 V, 1200 AMP AND FEEDING THE EXISTING LOAD WITH TEMPORARY POWER USING 4 GENERATORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16873	16041-10000-30155	6850 N RESEDA BLVD	91335	3	183B125   844	2125010***	[Q]C2-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.1953	-118.53583	PC FOR TITLE 24. TI FOR A RESTAURANT SPACE (ARBY'S). SCOPE INCLUDES NEW LIGHTING AND RECEPTECALES. TOTAL AREA  OF 14648 SQ.FT  1247 CONDITIONED AREA  AND 13401 HARDSCAPE*************************8/24/2016Owner information is missing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16874	16041-20001-11376	9251 W NIGHTINGALE DR	90069	4	150B169  1329	5561007013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM			PC Approved	04/12/2016 12:00:00 AM	ADDRESS	34.10376	-118.39047	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.2 kWac and consists of (66) modules, (66) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16875	15041-30000-42268	7168 N SALE AVE	91307	12	183B097   884	2024040026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Expired	02/05/2018 12:00:00 AM	ADDRESS	34.20078	-118.61891	Addition of new roof mounted solar PV array to existing roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac (3 kWac new).  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16876	11041-20000-17851	1540 S CARDIFF AVE	90035	5	129B169   499	4306018014	R1-1	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.05122	-118.39194	Roof mounted 7.74KW Photovoltaic system for single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16877	16041-20000-08508	11441 W HATTERAS ST	91601	2	174B169   240	2338014025	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.17589	-118.38042	PV1.  Install 3.6 kW roof-mounted PV system.  (1) 3.6 kW transformerless inverter with (16) modules.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16878	10041-10000-11882	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Public Safety Only			06/22/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Expired	12/03/2012 12:00:00 AM	ADDRESS	34.22149	-118.43179	NEW FIRE WARNING SYSTEM FOR A KAISER MEDICAL OFFICE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16879	18041-10000-32822	18433 W ROSCOE BLVD #106	91325	12	192B125   578	2786022035	QC1-1VL, QP-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.22091	-118.53469	PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVMENT TO THE (E) MEDICAL OFFICE. DEVELOP OFFICES, EXAM ROOMS, WAITING AREAS AND ADA RESTROOMS WITH NON LOAD BEARING WALLS - TOTAL AFFECTED AREA = 1665 SF. WITH CONNECTED LOAD OF APPROX = 150A OF NEW CONNECTED LOAF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16880	14041-20000-22056	5750 W WILSHIRE BLVD 150	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.06227	-118.3542	TI TO SUITE 150. NEW LIGHTING. PERMIT ALREADY ISSUED. THIS IS PLAN CHECK FOR T24 ENERGY ONLY. DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16881	13041-10000-31456	5464 S WEST BLVD	90043	8	108B185   624	5007019017	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	33.99115	-118.33541	PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 16 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16882	19041-20001-16185	22650 W CALIFA ST	91367	3	174B097   930	2040004084	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.17719	-118.62059	$0 plan check fee due to SB1222 and AB1414plan check only supplemental for changes to approved set. clouded changes only. No panel upgrade, and derating of the MCB on single line, minor reductions on load calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16883	13041-20000-17547	14200 W ARMINTA ST	91402	6	189B153   990	2212001017	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.21268	-118.44283	Plan check for food processsing facility. Class II Division 2 Group G Classified Area (Hazardous). Addition of new process line. Load is over 400A at 480V line to line.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16884	19041-20000-27921	8419 N GARDEN GROVE AVE	91325	12	192B125   437	2786025017	RS-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.2234	-118.52967	Plan check for PV roof mounted system, system size: 3.42KW with 12 PV Modules and 1 inverter(3.8KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16885	19041-10000-33374	3150 W WILSHIRE BLVD # 114	90010	10	132B197   112	5077010023	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.06163	-118.29086	ENERGY PC ONLY FOR INTERIOR T.I. OF EXISTING RESTAURANT (2577sqft).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16886	14041-10000-10567	4645 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.04717	-118.3388	PC FOR POWER AND ENERGY. CHANGE OF USE FROM BOWLING TO  GYM.  TOTAL AREA 22795 SQ FT. EMERGENCY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16887	16041-20000-20822	13535 W VAN NUYS BLVD	91331	7	207B157   848	2619026027	[Q]C2-1VL-O-CDO-CUGU, [Q]P-1-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.26187	-118.42829	NEW CHURCH.  FULL PLAN CHECK FOR PLACE OF ASSEMBLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16888	14041-10000-16500	2029 S CENTURY PARK EAST #500	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SUITE 500, HIGH RISE.  NEWLY CONNECTED LOAD < 400A.  13,777 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16889	16041-10000-45700	2023 S UNION AVE reception-office	90007	1	124-5A201  60	5124002021	[Q]C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.03665	-118.28252	PC FOR EENRGY ONLY T.I. RECEPTION AND NEW OFFICE. NEW LIGHTING AND POWER. SQFT 499	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16890	10041-20000-08770	9820 N TOPANGA CANYON BLVD UNIT A	91311	12	201B101   171	2746017031	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.24905	-118.60582	INSTALLING LIGHT IN RETAIL STORE. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16891	17041-20001-24605	15271 W LA MESA ST	91342	7	225B145   137	2501020029	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM			PC Approved	07/23/2017 12:00:00 AM	ADDRESS	34.31541	-118.46553	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.88 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16892	18041-20000-41007	2005 N HIGHLAND AVE	90068	4	150A185   119	5549030013	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Issued	11/16/2018 12:00:00 AM	ADDRESS	34.10671	-118.33767	TI of (E) hotel guestrooms and corridors.  Lighting and lighting control alterations.  Emergency egress lighting existing to remain.   (((TI OF (E) HOTEL TO RENOVATE GUESTROOMS: UPDATE TO FINISHES, FURNISHING AND REMODEL OF BATHROOMS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16893	13041-10000-18310	1755 N HIGHLAND AVE	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.10323	-118.33897	Tenant renovation (lobby ) for high rise hotel. title 24 plan check only.10600sqft. permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16894	17041-10000-43977	3415-3419 W 1ST ST	90004	13	138B197   742	5501007024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM			PC Info Complete	12/12/2017 12:00:00 AM	ADDRESS	34.07363	-118.28735	PC for T24 only for new lighting in existing buildings. Installing three new panels, receptacles, equipment and lights. Total area is 3945sqft. B# 17016-10000-30909. This application covers addresses 3415, 3417, 3419 1st st per building permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16895	15041-20001-16310	936 S OLIVE ST UNIT 252	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #14 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16896	18041-10000-31086	970 W 190TH ST 1ST FLR	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	33.85812	-118.29302	PLAN CHECK FOR T24 ONLY,  REMODEL TO EXISTING RESTROOM ON THE 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16897	16041-10001-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			08/17/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	CHANGES TO APPROVED SET BY REARANGING THE FLOOR PLAN, ADDING (5) EV CHANGERS, (2) PANELS, AND NEW CKTS. ALL  CHANGES UNDER DELTA 2 -5.(((FULL PC FOR POWER AND ENERGY  FOR A NEW 7 STORY MIXED USE BLDG.:  169 UNIT APARTMENT WITH RETAIL AND PARKING. SCOPE INCLUDES A NEW 4000A 277/480V 3 PHASE, 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. THERE ARE 11 TYPES OF APARTMENT UNIT PANELS. TOTAL AFFECTED AREA IS 160530 SQ. FT. B#16010-10000-03070Fire alarm modification was filed with the department 4/5/2017.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16898	14041-10000-11681	1635 W CARSON ST #101	90501	15	051B193   901	7349033025	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	33.83164	-118.30768	T.I. for existing commercial space - retail to restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16899	18041-10000-40653	111 E UNIVERSAL HOLLYWOOD DR 12TH FLR.	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.13855	-118.36112	TITLE 24 ONLY FOR 12TH FLOOR, RENOVATE RESTROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16900	11041-10000-13449	16720 W MARQUEZ AVE	90272	11	129B121   745	4415007009	C1-1XL	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM	06/28/2011 12:00:00 AM		Permit Finaled	08/24/2014 12:00:00 AM	ADDRESS	34.04741	-118.5454	New fire alarm for a private pre school.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16901	19041-20000-32005	9411 N BIANCA AVE PV1	91325	12	198B129    96	2766018002	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.24172	-118.51425	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.2KW DC/11KW AC SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH MICROINVERTERS, AND A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16902	17041-20000-39776	5309 N ALHAMA DR	91364	3	171B105   415	2167003028	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.16566	-118.59398	PV1.  Install roof mounted PV system sized 3.8kW interconnected with MSP.This is system (2) of a two part system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16903	18041-20000-24367	11241 W OTSEGO ST	91601	2	171B173   852	2353003019	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			06/29/2018 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	34.16307	-118.37627	Plan check for power and energy for new apartment building 3 story 42 units Service size: 1600A. Total area: 29,184 sq ft.  B#17010-10000-04951	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16904	19041-10000-05803	15303 W VENTURA BLVD 1600	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	T24 PLAN CHECK FOR INSTALLING NEW ELECTRICAL AND LIGHTING FOR A TENANT IMPROVMENT FOR EXISTING COMMERCIAL HIGH RISE. TOTAL SQUARE FOOTAGE = 5,483 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16905	17041-20002-04899	11711 W PICO BLVD	90064	11	123B149   653	4260029033	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM			PC Approved	07/11/2018 12:00:00 AM	ADDRESS	34.03159	-118.44613	07/11/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the lighting floor plans and have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****New plan design for lighting system for office addition. Plan check for energy.  (((Office addition to (E) commercial structure.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16906	14041-20001-18655	13626 N SHABLOW AVE	91342	7	228B161   550	2580003021	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			PC Approved	07/25/2014 12:00:00 AM	ADDRESS	34.32044	-118.40808	Expedite fee rooftop solar	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16907	14041-20000-07486	19648 W CRYSTAL RIDGE LANE	91326	12	219A117   402	2701012091	RD3-1, RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch		1082.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.29385	-118.56208	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING TRANSFORMERLESS INVERTER USING NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16908	13041-10000-35393	3436 N LINDA VISTA TER	90032	14	142-5A235  96	5219012014	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Expired	03/21/2016 12:00:00 AM	ADDRESS	34.08578	-118.17123	"PV1, Install 4 kW DC roof-mounted solar array, interconnect with main service panel for a one story house. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) modules Trina Solar TSM-250PA05.18.""COMPLY WITH DEPARTMENT ORDER effective date09/30/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16909	16041-20001-21232	10350 W DIAMOND ST LOT 16	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16910	12041-10000-01917	4220 W 3RD ST 102	90020	4	135B193   221	5503005022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.01	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.06883	-118.30609	Plan check power and energy TI for Plastic Surgery Center (Unit #102). New panels, equipment, and branch circuits. Existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16911	13041-20000-00571	9407 N YOLANDA AVE PV-1	91324	12	198B121   236	2763016029	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.24112	-118.54058	PV-1. Montes Residence. 5.28kW. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16912	18041-20001-40518	11869 S TEALE ST	90230	11	105B165   394	4220006065	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	33.98458	-118.4024	"02--14-2019 Changes to an approved set of plan, changes include replace new lighting fixture in the same location, remove panel and relocate load, no load being added. All changes has been clouded as delta ""F"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16913	15041-20000-20557	20458 W RUNNYMEDE ST	91306	3	186B109   571	2114009035	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Expired	08/10/2017 12:00:00 AM	ADDRESS	34.20579	-118.57927	PV1. Install roof mounted PV system sized 15.2 kW. Interconnected with main service panel(59) Kyocera KU2656 modules(2) Fronius Primo 7.6 Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16914	16041-20002-22361	4350 N LAUREL CANYON BLVD	91604	2	165B165   455	2368013052	[Q]C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.14989	-118.39625	[[2/10/17 SUPPLEMENTAL PLANCHECK ONLY FOR T24 CHANGES.  ]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16915	17041-10000-29840	1648 W 9TH ST	90732	15	015B189   180	7560002001	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	33.73668	-118.3133	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
16916	14041-10000-01908	5310 S BEETHOVEN ST	90066	11	102B157    21	4211009004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	33.97877	-118.4225	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT WITH NO NEW SF TEST KITCHEN WITHIN EXISTING HEALTH FOOD WHOLESALE FOOD PROCESSING ESTABLISHMENT.  1361 SQFT, NO EMERGENCY LIGHTING  REQUIRED ACCORDING TO APPLICANT.BUILDING P# 14016-10000-01243	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16917	15041-10001-37272	1800 N BRONSON AVE	90028	13	150A191   355	5586028900	PF-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	34.10355	-118.31784	11/17/2015Changes to an Approved set, changes were made to only include the restrooms to the scope of work. Note changes on delta 1. (((Energy plan check for an office T.I, Scope includes new lighting only; Total area is 2255-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16918	17041-20002-33232	12940 W ADDISON ST	91423	4	168B161    16	2358023021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.16107	-118.41537	09/29/2017 Changes to an approved set of plans. PV AC system size has not changed. Module count has increased by (21) modules for a total count of (48) modules.Note: $0.00 permit fee due to CA Senate Bill 1222*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (27) modules. PV system interconnects with a 400-amp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16919	14041-10000-03872	4376 N FORMAN AVE	91602	4	165B181   204	2424024001	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.15018	-118.35257	PV1, Install 5.75 kW DC roof-mounted solar array for one-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 6000A-US. (23) Modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16920	13041-20000-00203	3485 S ASHWOOD AVE	90066	11	114B149  1102	4244023018	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	05/08/2013 12:00:00 AM	ADDRESS	34.00461	-118.44983	New 5.39kw rooftop mounted PV system for an existing single family residence.  System is ungrounded/transformerless with modules on a separate garage structure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16921	15041-20000-05968	23117 W CALIFA ST	91367	3	177B097   575	2041021006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.17749	-118.63026	Installation of new roof mounted solar PV central inverter system.  Total system size = 10 kWac.  2 inverters with 2 strings each (10 modules per string).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16922	15041-10000-23379	6101 W CENTURY BLVD	90045	11	090B169     4	4124030036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	33.9457	-118.39149	T-24 ON EXISTING RETAIL BUILDING. SCOPE OF WORK INCLUDES LIGHTING AND RECEPTACLES. TOTAL AREA IS 1222 SQ. FT. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16923	15041-10000-40819	21301 W BURBANK BLVD 1st Flr	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.17351	-118.59524	Energy plan check for an Interior office TI. Scope includes new lighting, receptacles and ewuipment. Total area is 29,210 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16924	12041-10002-10371	4160 W WILSHIRE BLVD #201	90010	4	132B189    60	5092001046	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.06152	-118.31825	Revision to approved plans. Changes on the lighting plan and T24 calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16925	19041-10000-34411	763 E 15TH ST	90021	14	123A211   349	5132026024	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.02972	-118.25347	PC FOR T24 ONLY, SCOPE OF WORK IS CHANGE OF USE FROM OFFICE/WAREHOUSE TO OFFICE/ INDOOR NURSERY AND TENANT IMPROVMENT. TOTAL AFFECTED AREA IS 1965 SQFT.NOTE FULL PLAN CHECK MAY BE REQUIRED PER INSPECTOR REQUESTNOTE PARTIAL PERMITS HAVE BEEN PULLED UNDER 19041-70000-07081B# 18016-10000-23588NOTE PLANS ARE PENDING STAMP AND SIGNATURE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16926	13041-10000-34486	14161 W SAYRE ST	91342	7	222B153   617	2508013018	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.3028	-118.44221	PV1, Install a 3.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (13) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16927	16041-20001-07887	16501 W VENTURA BLVD Suite 410	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.1578	-118.49275	[[5/18/16  CHANGES TO APPROVED SET. ADDITION OF 4 FIXTURES]]]Plan check for energy only. TI to existing office on 4th floor of existing high rise building.New lighting (incl. emergency) and receptacles. 1,302 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16928	16041-10000-21916	308 W FLORENCE AVE	90003	9	102B201   892	6031003014	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM			PC Approved	06/22/2016 12:00:00 AM	ADDRESS	33.97446	-118.27876	PC for energy, title 24 only. Fire damage commercial unit under repair remodeling. Adding new lighting and power. Installing (1) New panel rated at 100 amps. Total sqft = 668. B#16016-10000-04469note: Permit pulled under PCIS#16041-10000-11967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16929	15041-10000-06009	1212 S STANFORD AVE Suite 203	90021	14	123A211   172	5132013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.03162	-118.25005	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16930	12041-10000-06434	1950 CENTURY PARK EAST GROUND-3RD FLOOR	90067	5	132B161    21	4319001008	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	PIN	34.06062453	-118.41312336	PLAN CHECK TITLE 24/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT. 12618 SQFT. CONSISTS OF BASEMENT THROUGH 3RD FLOOR.  GYM.  ((CUSTOMER SPECIFIED LIGHTING FIXTURES IN MY PRESENCE AND APPROVAL))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16931	13041-10000-06422	6300 W ROMAINE ST 100 & 120	90038	13	144B185   960	5533020023	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.08878	-118.32903	FULL PLAN CHECK FOR FIRST TIME TENANT IN DANCE STUDIO. 10860 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16932	11041-10000-14310	6107 W MELROSE AVE	90038	4	141B185   554	5533037024	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	34.08362	-118.33352	T.I. TO AN EXISTING BLDG (EK-12).  COMBINING TWO SEPERATE RETAIL SPACES INTO ONE FOR A NEW VOCATIONAL EDUCATION FACILITY.  PLAN CHECK IS FOR ENERGY WITH EMERGENCY ONLY.  <<<FULL PLAN CHECK MAY BE REQUIRED SUBJECT TO FIELD INSPECTION>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16933	17041-10000-43737	7242 N VALJEAN AVE	91406	6	186B137   367	2205027029	MR1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM			Reviewed by Supervisor	12/11/2017 12:00:00 AM	ADDRESS	34.2024	-118.48575	PC for new rooftop 54kW solar for commercial building. Installing 154 Hansol solar TD-AN3 modules, one SMA 24000TL-US inverter and one SMA-30000Tl-US inverter and one 100A panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16934	18041-10000-24714	7659 N TOPANGA CANYON BLVD	91304	3	186B101    36	2012022012	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.20995	-118.60619	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16935	11041-10000-17025	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	04/16/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	T.I.  Core and shell.  New gym to occupy the space.  Two story building. Plan check is for energy and power.NOTE TO PLAN CHECKER: Note to plan checker:  Applicant brought a pre-printed check.  The number of branch circuits were reduced from 209 to accomodate aplicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16936	19041-20001-00923	1750 N VINE ST 7th Floor	90028	13	148-5A189   4	5546030028	(T)(Q)C2-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.10311	-118.32649	VOID PER APPLICANT REQUEST.<<SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. REVISED TO EXIT SIGN EXISTING TO REMAIN.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16937	12041-10000-20316	2307 N LAKE SHORE AVE	90039	13	145-5A211 103	5443002010	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.09417	-118.2526	2.86 Roof mounted solar for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16938	18041-10000-38014	7510 N HAZELTINE AVE	91405	2	186B153    97	2215015012	M1-1, MR1-1, P-1VL, R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.20701	-118.43985	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16939	07041-10005-12960	1724 N HIGHLAND AVE	90028	13	148-5A185  63	5547011023	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM			PC Info Complete	04/20/2010 12:00:00 AM	ADDRESS	34.10238	-118.3385	Plan check only. Plan check for revision to approved plans.  Delta 8 indicated on plan to reflect field changes.((((((((((((((((((((((((((((((    revision to pap the panel HS and HPP removed two fault calc performed  for EHA and fire alarm feeder.)))))))))))))))))))))))))))))))))))))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16940	13041-10000-21150	12652 W VILLAGE LANE bldg #9	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #9	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16941	10041-10000-25038	12930 N BRADLEY AVE	91342	7	222B149   483	2506010007	M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.30488	-118.45883	TI IN AN EXISTING COMMERCIAL BUILDING ON THE 1ST FLOOR. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16942	12041-20000-25063	16133 W VENTURA BLVD 700	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.15675	-118.4847	PC FOR T24. EXISTING OFFICE TI REMODEL. NO EMERGENCY LIGHTING (EXISITING)  2200SF HI RISE. SUITE 700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16943	14041-10000-12755	13604 W LEMAY ST	91401	2	180B157   213	2329001040	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.19255	-118.42933	PV1, INSTALL 5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL,  WITH OTIMIZEERS AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16944	13041-20000-17873	12121 N BALBOA BLVD	91344	12	216B133    73	2606001014	[T]RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02, 1066.42	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	07/15/2013 12:00:00 AM	ADDRESS	34.29149	-118.50226	ADDITION OF EXTERIOR LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED FROM THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16945	12041-10000-30359	901 E E ST	90744	15	030B209   720	7424018083	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Info Complete	02/07/2013 12:00:00 AM	ADDRESS	33.77631	-118.25153	PLAN CHECK FOR METHANE MITIGATION SYSTEM. USING 17 DEVICES AND 1 PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16946	11041-20000-21530	3415 S SEPULVEDA BLVD Ste. 310	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	T.I.  Remodel of the light fixtures in Suite #310.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16947	11041-10004-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	33.94386	-118.4047	REVISION MADE TO PREVIOUSLY APPROVED SETS OF PLANS. THESE PLANS REFLECT CHANGES  OUTLINED  IN BULLETIN 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16948	18041-10000-01313	17331 W TRAMONTO DR Bldg # 5	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 5 (CAMPUS STYLE)SCOPE INCLUDES 105 DEVICES AND 3 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE. B# 16010-10001-00079 BUILDING 5  (PLAN B1/ B1R)  8 UNITS AND 4 STORY  TYPE IIA  APARTMENT  BUILDING WITH  TYPE IB GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16949	19041-10000-15694	15148 W BLEDSOE ST	91342	7	222B145   121	2506002030	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	08/26/2021 12:00:00 AM	ADDRESS	34.30689	-118.46319	(Assign to Edwin or John per Mr. Nabil request) PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES1998 MODULES (Q-PEAK 390), 1026 OPTIMIZERS (P850 ), 6 INVERTERS ( SE 99.9K) . SYSTEM SIZE IS 599.4KWac AND 779.22KWdcPERMIT FEE IS $ 0 DUE TO AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16950	17041-10000-18079	8739 N BAIRD AVE	91324	12	195B125   714	2770015015	M1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Issued	05/31/2017 12:00:00 AM	ADDRESS	34.22997	-118.53749	REPLACE HID FIXTURES FOR LED TYPE. REDUCING WATTAGE. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16951	18041-20001-36812	1030 N SWARTHMORE AVE 3-105A	90272	11	129B125   668	4412002016	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Plan check for first time tenant, plan check for power only, Energy plan check approval is under 18041-20000-36812, 100A sub panel feeding from 45KVA Transformer. B#18016-10000-19862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16952	18041-20000-30786	16660 W LABRADOR ST	91343	12	201B137   302	2686004010	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	PIN	34.2490813	-118.49588086	Express permit for a 225 Amp main panel upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16953	15041-10000-42301	851 W MIRAFLORES AVE	90731	15	021B197   554	7447020035	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	33.75267	-118.29585	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(32) KYOCERA KU255 MODULES(1) FRNIUS 7.6 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16954	19041-20000-33113	21935 W VENTURA BLVD	91364	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.16868	-118.60496	TI to (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16955	18041-10001-16626	1370 N ST ANDREWS PL	90028	13	147A193   187	5544030056	(Q)C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.09641	-118.31076	Changes to approved set noted as Delta-13. Changes affect majority of plan due to architectural change, relocate and revise loads on floor plans and panel schedule. One new panelboard.Orginal scope of work: ((PC FOR POWER AND ENERGY FOR  REMODEL OF EXISTING TWO STORY BUILDING AND BASEMENT.  WORK INCLUDES 60 PODS ON GROUND FLOOR. NEW SERVICE 2500A 480/277 V TOTAL AFFECTED AREA 97293 SQ.FT B #18016-10000-04168 ))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16956	13041-20000-28078	15821 W VENTURA BLVD SUITE 225	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Approved	10/09/2013 12:00:00 AM	ADDRESS	34.15584	-118.47812	T24 FOR EXISTING LOW RISE OFFICE BUILDING. SCOPE OF WORK ON SUITE 225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16957	18041-20000-11005	4656 N BLACKFRIAR ROAD	91364	3	168B097   753	2076012021	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.15323	-118.6222	Plan check for a PV1 roof-mounted PV system. System size is 13.2 kWac and consists of (2) inverters, (45) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16958	14041-10000-12789	10490 W WILSHIRE BLVD 1-130	90024	5	135B157   293	4326037***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.06466	-118.43146	PLAN CHECK FOR ENERGY ONLY FOR EXISTING HIGHRISE CONDO BLDG. TOTAL SQRFT AREA IS 31000. TOTAL NEW LOAD DOES NOT EXCEED 400A.  INSPECTION FEE SHALL COVER LIGHTING CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16959	12041-10000-28687	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	33.93195	-118.41136	T.I. For the food processing plant at LAX (LSG Sky Chefs).  Adding new lighting, receptacles and power equipment.  New load is less than 25 amps.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16960	17041-10000-04487	1015 W E ST BLDG 6	90744	15	030B201   837	7417012925	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM				Plan check for new Fire alarm system new appartment building 7 units. Total fire alarm devices: 40 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16961	16041-10000-10926	1522 S ABBOT KINNEY BLVD	90291	11	108B145  1546	4238005028	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.98995	-118.46405	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (RETAIL/TEA AND ACCESSORY STORE). SCOPE INCLUDES 1 NEW 200A PANEL, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 919 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16962	11041-20000-21964	19515 W BUSINESS CENTER DR	91324	12	195B117    47	2783025097	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	PIN	34.23184009	-118.55899691	T.I.  Installing new lights in the new processing room.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16963	16041-20000-39161	13355 W CANTARA ST	91402	6	192B157   783	2301001032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.21996	-118.42454	PV1.  Install roof mounted grid-tied PV system sized 14kW.$0 permit fee due to Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16964	09041-10002-19704	5331 E HUNTINGTON DR NORTH BLGD 3	90032	14	145-5A237 252	5309017020	(T)[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Apartment			03/17/2011 12:00:00 AM	03/17/2011 12:00:00 AM		Permit Finaled	01/24/2012 12:00:00 AM	ADDRESS	34.09124	-118.16464	New low-income housing project.  3 separate buildings w/ 25 units totals.  Bldg1 - 4 units - Permit # 09041-10001-19704,       Bldg 2 - 15 Units - Permit # 09041-10000-19704  &   Bldg 3 - 6Units - Permit # 09041-10002-19704  <<<<<THIS PERMIT IS FOR BUILDING #3>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16965	19041-30000-47731	8850 N TAMPA AVE #106	91324	12	195B117   410	2784003072	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.23108	-118.55333	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI (CHANGE OF USE) SCOPE INCLUDES NEW LIGHTING, CIRCUITS, AND ONTROLS. TOTAL AFFECTED AREA IS 950 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16966	13041-10000-05525	1111 W SUNSET BLVD	90012	1	136-5A211 440	5406020003	C2-2D	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			03/04/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.06583	-118.24918	"NEW FIRE ALARM SYSTEM FOR HIGH RISE COMMERCIAL ""ADAPTIVE REUSE"". A WORK AND LIVING SPACE BUILDING. 209 DEVICES AND 1 FIRE ALARM PANEL."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16967	16041-10000-43096	18719 W TULSA ST	91326	12	207B121    30	2717016023	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.26765	-118.54009	PV1 roof mounted solar systeem to a single family home. Tilt greater than 20 in. (bldg approved). Installing microinverters for a total size of 7.7 kW, 36 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16968	14041-10000-15691	11755 W WILSHIRE BLVD 17	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	PIN	34.04869377	-118.46238681	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS ON 17TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16969	16041-10000-05073	6340 N CREBS AVE	91335	3	180B121   680	2127022020	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.1859	-118.54363	PV1 roof mounted installation to a single family home with a central inverter rated at 7.6 kWac and 33 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16970	15041-20000-03721	7357 W HOLLYWOOD BLVD	90046	4	147B181   152	5550001029	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.10179	-118.3503	TI TO AN EXISTING COMMERCIAL KITCHEN.  ADDING NEW LIGHTING NEW CONTROL NEW CIRCUITS.  USING EXISTING PANEL.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 686.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16971	15041-20001-00587	16145 W CHASE ST	91343	12	192B141   165	2673002038	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2015 12:00:00 AM			Corrections Issued	01/21/2015 12:00:00 AM	ADDRESS	34.22484	-118.48439	EXPEDITE PER CUSTOMER REQUEST.PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 17 MODULES IN TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16972	14041-10000-10736	6030 N BONNER AVE	91606	2	177B173  1010	2337004028	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	34.18031	-118.37402	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. USING STANDARD PLAN. 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16973	14041-20000-13744	10449 N MEMORY PARK AVE	91345	7	207B145   718	2649021002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.26055	-118.46421	PV1.  Install 4.5 kW roof-mounted utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16974	18041-20000-14587	11800 W COURTLEIGH DR #1-18	90066	11	111B161   801	4233023021	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			04/20/2018 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	11/23/2022 12:00:00 AM	ADDRESS	33.99835	-118.41781	Plan check for power and energy for 18 units appartment 3 story over parking garage 1000A Service. Total area: 26,392 sq ft. B#17010-20000-02925Fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16975	12041-20000-08354	4222 W PICO BLVD	90019	10	129B185  1095	5082023024	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM			PC Approved	04/12/2012 12:00:00 AM	ADDRESS	34.0477	-118.32765	TI for existing commercial space. Plan check for energy and emergency lighting. 1349 conditioned sqft. Single story commercial. Mateo's Ice Cream and Fruit Bars.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16976	15041-20000-11523	4305 N LAUREL CANYON BLVD	91604	2	165B165   645	2367004045	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			04/17/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.14888	-118.39665	Plan check for power and Title-24 (energy).  Total area = 2,398 sq. ft. (indoor) + 3,250 sq. ft. (outdoor)  New 12 unit 3 story apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16977	15041-10001-43807	22534 W LASSEN ST	91311	12	201B097    18	2727003004	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.24973	-118.61814	Supplemental PC, using (E) 125A panel to run from backhouse where the solar is installed to the Main house panel. Additional fee zero dollar $0 per California Senate Bill 1222.Permit under 15041-20000-43807***PV1, rooftop solar installation 6kW AC system(23) SE-F270(1) SE6000A-USSE P300 is used.Standard plan is used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16978	13041-10000-34203	12209 W WILSHIRE BLVD SUITE B	90049	11	126B145   232	4264026006	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	PIN	34.04347531	-118.46880107	pc for energy only. permit to be pulled at EPC counter. less than 400A. emergency lights installed. 1 story. Air Force recruiting office.changes on plans include addition of Occupancy sensors (watt stopper) to the two small offices and missing lights to calcs.INSTALL NON-BEARING PARTITION WALL TO ENLARGE & BUILD NEW OFFICES ON EXISTING TENANT IMPROVEMENT.  CHANGE OF USE FROM RETAIL SPACE TO OFFICE. NO CHANGE IN PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16979	19041-10000-34698	7901 N SEPULVEDA BLVD	91405	6	189B145   468	2222002020	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM			PC Info Complete	09/03/2019 12:00:00 AM	ADDRESS	34.21404	-118.4664	PLAN CHECK FOR TITLE 4 ONLY FOR CHANGE OF USE FROM EXISTING RETAIL/WAREHOUSE/WHOLESALE TO NEW AUTOMOBILE SALES/REPAIR AND OFFICE SPACE. ONLY AREAS WHERE OFFICES ARE BEING LOCATED HAVE BEEN ALTERED EVERYTHING ELSE STAYS THE SAME - TOTAL AFFECTED AREA 1869 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16980	11041-10001-27352	648-654 S BROADWAY	90014	14	127-5A211  32	5144002023	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Expired	07/08/2014 12:00:00 AM	ADDRESS	34.0454	-118.25294	Modification to previously approved plans to correct inconsistency of  Switchboard SB-1 to show 1600A on the single line.  No other changes.       <<<<Plan check power only. New two 800A services serving existing commercial building with new switchboards, panels, emergency generator, ckts and equipment. **Additional fees required, verify all fees when Final>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16981	12041-20000-01709	14150 VAN NUYS BLVD	91331	6	201B153    32	2645021001	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	PIN	34.25148177	-118.4414952	New 800 amp service for a new retail building with mezzanine (CORE AND SHELL).  New panels and branch circuits.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16982	15041-10000-43430	6344 N SEPULVEDA BLVD	91411	6	180B145   859	2242010028	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.18605	-118.46591	NEW MCC AND ASSOCIATED LOADS. NEW LIGHTING. PC FOR POWER AND ENERGY GREATER THAN 400A LOADS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16983	11041-10001-05259	3054 W PICO BLVD	90006	10	129B193  1324	5074001006	C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM			PC Approved	04/06/2011 12:00:00 AM	ADDRESS	34.04702	-118.30782	CHANGE THE APPROVED PLAN. CHANGE THE LIGHTING & T24 CALC. EPC IS FOR T24. ((((((((((((T.I.    NEW OFFICE SPACES.  USED TO BE A CLUB.  NOT ADDING ANY NEW PANNELS.  SINGLE STORY.  1993 SQFT.  WILL DO TITEL 24 PLAN CHECK.  FULL PLAN CHECK MAY BE REQUIRED SUBJECT TO INSPECTOR.))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16984	17041-10000-46453	10538 W EDGELEY PL	90024	5	135B153    65	4360021048	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.06932	-118.4366	NEW ROOFTOP SOLAR SYSTEM WHICH CONSIST OF 26 SOLAR MODULES (LG ELECTRONICS LG335N1C-A5) WITH MICRO-INVERTERS (ENPHASE IQ6PLUS-72-2-US).  SYSTEM SIZE IS 8.71KWdc and 7.28KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16985	10041-20000-11515	11150 W SANTA MONICA BLVD SUITE-1060	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	lighting and receptacles in unit 1060. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16986	17041-10000-06048	15200 W MAGNOLIA BLVD	91403	4	171A147    14	2263002014	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			02/24/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.16459	-118.46421	Plan check for power and energy for 10 units appartment builidng for 800A service. Total area: 8,386 sq ft.Building permit under 16010-20000-00464. Inspector to confirm that all equipment is listed for 75 deg terminals or is dual rated 75/60 deg c. Fire variance was filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16987	14041-20000-31493	515 S FIGUEROA ST parking-level	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Issued	11/19/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for energy only. New/alter lighting in valet lobby and drop-off areas. 3,580sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16988	19041-10000-50355	1453 W 53RD ST	90062	8	108B193   335	5003009014	R2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	33.99426	-118.30198	NEW ROOF MOUNTED 4.84KW PV SYSTEM WITH 17 @ (285W) PV PANELS AND OPTIMIZER AND ONE 3.8KW CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16989	13041-10000-24911	6743 N VESPER AVE	91405	6	180B149    60	2236008006	R1-1-HPOZ, [Q]RD1.5-1-HPOZ	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM			Corrections Issued	09/11/2013 12:00:00 AM	ADDRESS	34.19339	-118.45113	PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 3 KW DC IN A 2-STORY HOUSE. (12) MODULES: TRINA 250(1) INVERTER: SOLAREDGE #SE3000A-USPOWER OPTIMIZERS: OP250-LV	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
16990	13041-20000-35681	21700 W OXNARD ST SUITE 580	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.17901	-118.60179	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON SUITE 580	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16991	13041-10001-36026	380 WORLD WAY CONNECTOR-BLDG	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	"01/22/16Changes to an approved set. All changes made under delta 12. Changes include upsizing the UPS from 50KVA to 120KVA, increasing sizes of circuit breakers on panel ""2HBHS,"" and increasing conductors and feeders. Note: Original application is under PCIS#13041-10001-36026(((plan check for power and energy. PROPOSED 4-STORY TYPE IB  ADDITION ( CONNECTOR BUILDING)  BETWEEN  EXISTING  TERMINAL 4  AND THE TOM BRADLEY INTERANTIONAL TERMINAL (TBIT). PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX 68,000 SQ FT.FIRE ALARM VARIANCE FILED ON 12/27/2013"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16992	15041-10000-27564	5835 S VILLAGE DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/21/2015 12:00:00 AM			Reviewed by Supervisor	09/03/2015 12:00:00 AM	ADDRESS	33.97525	-118.41534	New Apartment- 4 story bldg., 6 units. Level one includes parking.Ref. to Build. permit #15010-10000-01751	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16993	13041-10000-22889	13361 N GLENOAKS BLVD BLDG C	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.3146	-118.45921	][][]FILE ALARM VARIANCES WILL BE FILED FOR THIS PC APPLICATION][][][]NEW HIGH SCHOOL BUILDING ADDITIONS ( 2 TOTAL- EACH HAS 27,354 SF & IS A REPLICATE OF THE OTHER) . FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW CHARTER HIGH SCHOOL. THIS APPLICATION IS FOR BUILDING C.  SINCE BOTH BUILDINGS ARE EXACT DUPLICATES OF THE OTHER, FEES WILL BE CHARGED BASED ON HALF OF THE TOTAL FOR BUILDING B, AND THE OTHER HALF WILL BE BASED OFF BUILDING C.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16994	16041-20000-09172	5600 N OSTIN AVE	91367	3	174B089   424	2046007028	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.17235	-118.65324	$0 permit fees due to senate bill 1222Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 175A.System size: 11kW (6+5). Ungrounded system. (54) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
16995	17041-10000-44888	361 1/2 N LA CIENEGA BLVD	90048	5	138B173   140	4337012027	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.07776	-118.37679	Plan check for T24 only for change of use from package food (retail) to small coffee shop 654 s.f.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
16996	16041-20002-09233	13604 W SHERMAN WAY	91405	2	183B157    75	2328008074	(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.20102	-118.4293	Install a roof-mounted solar array on a 5-story 65 unit apartment building.System size: 14kW. Ungrounded system. (70) 275W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16997	13041-20000-11834	18425 W BURBANK BLVD #412	91356	3	174B125   635	2160001023	C2-1L, C4-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.17242	-118.53474	PLAN CHECK FOR MEDICAL OFFICE TENANT SPACE (SUITE #412)   NOT A HIGH-RISE BUILDING.  NOT A STATE LICENSED BUILDING PER ENGINEER, NOT CHECKED FOR OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16998	18041-20000-04592	13129 N CONSTABLE AVE	91344	12	222B133    51	2602002009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.30858	-118.50329	Plan check for the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
16999	16041-20001-18557	822 E 75TH ST	90001	9	102B209   346	6023014006	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	33.97193	-118.25998	Expedite per applicant request. {{{{{Plan check for PV roof mounted system in house duplex single structure. The system connectted to 2 meters splite bus 200A each  on single structure. System size: 14kW with 44 AC modules.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17000	17041-20000-26205	905 E 2ND ST #105	90012	14	129A215   387	5163003063	(T)(Q)C2-2D-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	07/09/2020 12:00:00 AM	ADDRESS	34.04729	-118.23499	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 4,880 sq. ft.Note: Building application has been generated under 17016-10000-11345	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17001	15041-10000-42859	6255 W SUNSET BLVD SUITE 1040	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.09815	-118.32564	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK IS ON THE 10TH FLOOR SUITE 1040.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17002	16041-10001-42001	8500 W BEVERLY BLVD 501	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			PC Approved	08/01/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLAN CHECK ONLY - CHANGES TO APPROVED SET OF PLANS UNDER DELTA 1 AND 2 ONLY - CHANGES INCLUDE ADDITION OF GENERAL USE RECEPTACLES & ADDITION OF LIGHT FIXTURES. ORIGINAL PLAN 160041-10000-42001PC FOR T24 ENERGY ONLY. OFFICE TI TO THE 5TH FLOOR IN A COVERED MALL. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4433 SQ. FT. B#16016-10000-27527	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17003	14041-20003-08218	6600 N TOPANGA CANYON BLVD #2072 A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	09/04/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	CHANGES TO APPROVED SET OF PLANS. ALL CHANGES HAVE BEEN CLOUDED. THIS PLAN CHECK COVERS DELTA REVISIONS 2 AND 8. CHANGE TO LIGHTING AND LOAD REORGANIZED. THIS APPLICATION IS PLAN CHECK ONLY. NO PERMIT TO BE ISSUED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17004	15041-20000-42980	10860 N TOPANGA CANYON BLVD	91311	12	210B101    77	2722004015	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.26773	-118.60586	Plan check for new 1 story community center. Plan check for energy only. Adding new lighting. Total sqft. 2,570. Note: Building Permit #12010-20000-01008 Using 2008 TITLE 24 Forms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17005	19041-30000-52018	10100 W SANTA MONICA BLVD Ste. 1400	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	34.06191	-118.41691	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND POWER. TOTAL AFFECTED AREA IS 5289 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17006	17041-20002-12202	16188 W ROYAL OAK ROAD	91436	5	162B141   272	2286013015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM			PC Approved	04/23/2017 12:00:00 AM	ADDRESS	34.13958	-118.48337	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.78 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17007	17041-20000-33831	3127 S CORINTH AVE	90066	11	120B157   631	4250022020	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.02416	-118.43129	Plan check for solar pv system, roof-mounted array on SFD.11.4kW ungrounded system. (40) 330W pv modules.Each module has a 400W power optimizer.Derating main breaker to 175A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17008	16041-20000-44451	15596 W OLDEN ST	91342	7	228B145   351	2501014015	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.31963	-118.4713	Installation of new roof mounted solar PV array on existing single family dwelling.  28 Sunpower SPR-E20 AC modules in 3 branch circuits.  Total system size = 9.156 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17009	12041-10000-00130	1600 N CAMPUS ROAD SWAN HALL	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	PIN	34.12750533	-118.21285206	Installation of a new fire alarm to an existing/addition building at occidental college.  182 new devices with a new control panel.  (Swan Hall Building).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17010	13041-20000-00206	3901 N LAKE VISTA CT	91316	5	162B129    15	2184048009	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.14197	-118.52421	New 11.76kw rooftop mounted PV system for an existing single family residence.  System is ungrounded/transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17011	16041-10000-33680	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Issued	10/05/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	FULL PC FOR POWER AND ENERGY, TI  FOR AN EXISTING LENSCRAFTERS INSIDE EXISTING MACY'S DEPARTMENT STORE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 769 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17012	16041-10004-34341	1700-1704 W SUNSET BLVD	90026	13	139-5A209 152	5404017020	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.0771	-118.25863	Delta 3 changes in the field: beer dispenser system connected to branch circuit from panel C; and added 3 new circuits to panel C;  added 48KW boiler ;removed loads from other panels.((((((((CHANGE OF USE TO RESTAURANT WITH BREWERY. PLAN CHECK PER APPLICANT REQUEST. PROVIDING NEW SERVICE SECTION 400A TAP OFF EXISTING SERVICE. NEW LIGHTING AND EQUIPMENT. PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17013	13041-10000-36133	5670 W WILSHIRE BLVD #1650&1690	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.06222	-118.35208	PLAN CHECK FOR T24 ENERGY ONLY. HIGHRISE. SUITE 1650 AND 1690. OFFICIES.  2670 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17014	14041-10000-25741	14610 W HILLTREE ROAD	90402	11	123B129    62	4409026008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.03694	-118.51575	PV1 6.48KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(24) inverters: {MICROINVERTER: ENPHASE ENERGY M250]}]. [(24)modules: {Suniva Optimus OPT270-60-4}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17015	18041-10001-26793	1310 S ABBOT KINNEY BLVD	90291	11	108B145  1283	4238004015	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM			PC Approved	12/07/2018 12:00:00 AM	ADDRESS	33.99094	-118.46783	"DELTA ""3"" CHANGES TO THE APPROVED PLANS FOR RELOCATION OF CIRCUITS.PERMIT WAS ISSUED UNDER: 18041-10000-26793<<<FULL PC FOR POWER AND ENERGY. TI FOR A RETAIL STORE. COMBINE 3 RETAIL STORES INTO ONE. SCOPE INCLUDES RELOCATINGS PANELBOARDS, AND ADDING NEW LOADS. TOTAL AFFECTED AREA IS 4,342 SQFT. BULDING PERMIT# 18016-10000-22884>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17016	15041-10000-19088	550 S MAIN ST	90013	14	127-5A211  13	5148020009	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.04546	-118.24932	Install new fire alarm system for a new mixed used apartment building(156 units) with 502 fa devices 0ne control panel and one fa panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17017	15041-10000-31783	950 N AVALON BLVD #105-#108	90744	15	033B205  1176	7423005034	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	33.78272	-118.26242	T-24, TI TO  AN (E) RETAIL BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES WITH NEW PANELS CONNECTED LOAD < 400AMPS. PC FOR ENERGY ONLY, TOTAL SQ. FT. 3287	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17018	18041-10000-03396	1840 S CENTURY PARK EAST	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.06188	-118.41473	T-24, PC FOR OUTDOOR LIGHITNG IN THE DECK AREA OF A HIGH RISE BUILDING. DECK AREA IS IN LOCATED IN THE SECOND FLOOR, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1715.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17019	14041-10000-33619	1243 S OLIVE ST	90015	14	126A207   200	5139023038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.03859	-118.26331	INSTALL NEW FIRE ALARM SYSTEM FOR A MIXED USED APARTMENT BUILDING, WITH 871 DEVICES  AND ONE CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17020	16041-10000-09014	119 E 5TH ST	90013	14	129A211   203	5148009008	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.04634	-118.24781	pc for ti to new cafe. t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17021	13041-20000-16365	1441 W OLYMPIC BLVD Burns-Flr 1 - 2	90015	1	129A205   148	5137005021	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.04841	-118.27203	Plan check for energy and emergency lighting. Offices of Loyola Law School. Burns Building. Express permit includes 13 outlets on 2nd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17022	16041-20000-01211	8708 N NOTTINGHAM PL	91325	12	195B133   531	2690010025	[Q]RD4-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.22886	-118.50299	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (29) Kyocera KU2656 Modules(1) ABB PVI 6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17023	16041-10000-42324	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.24138	-118.60168	T-=24, PC FOR ENERGY ONLY. CHANGE OF USE FROM WAREHOUSE TO OFFICE ANDINTERIOR REMODEL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 13891 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17024	14041-10000-17161	2710 E MEDIA CENTER DR	90039	1	150B213  3658	5442032006	[Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	PIN	34.10636393	-118.24150489	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR JPMORGAN CHASE. NEWLY CONNECTED LOAD <400 AMPS. NO CHANGE OF OCCUPANCY. 3809 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17025	12041-10000-26290	550 S CERES AVE	90013	14	126A215   134	5147015042	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.04022	-118.24082	FULL PLAN CHECK TENANT IMPROVEMENT ELECTRICAL PERMIT for remodeling per inspector's request. RE-NEW EXPIRED PERMIT#09041-10000-21979TENANT IMPROVEMENTS- REPLACE EXISTING FLUORESCENT LIGHTS, REPLACE EX. OUTLETS AND SWITCH'S. ADD NEW BATH EXHAUST FAN FOR (2) NEW ADA BATHROOM FOR MISC. T.I. WORK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17026	14041-20000-05179	2007 S BARRY AVE	90025	11	123B149    31	4262030002	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.03734	-118.44923	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17027	16041-20000-12628	3501 S TROUSDALE PKWY B80	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM			PC Approved	04/12/2016 12:00:00 AM	ADDRESS	34.02194	-118.28455	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 633 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17028	16041-30000-35022	7900 S WESTERN AVE	90047	8	099B193   794	6034001025	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	33.96717	-118.3088	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.  Total area = 30,275 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17029	18041-10000-40835	403 W ADAMS BLVD	90007	9	121-5A205 317	5126017018	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.02746	-118.27394	TI IN A MEDICAL BUILDING. INSTALLING A NEW AIR HANDELING UNIT PLUS OTHER LOADS.BULDING PERMIT: 18016-10000-34572	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17030	16041-10004-39304	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 4 ON PLANS. CHANGES TO SINGLE LINE AND PANELS. LOAD UPDATE. NO ADDITIONAL LOADS NOTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17031	18041-10000-15830	1547 N HAZELWOOD AVE	90041	14	157-5A221 268	5474012002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.12437	-118.2147	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (17) MODULES WITH OPTIMIZERS AND (1) INVERTER 3.8KWAC. TOTAL SYSTEM SIZE IS 3.8KWAC, 5.185 KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17032	18041-20000-02806	12964 W PANAMA ST PKG GRG	90066	11	105B157   569	4223008010	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	33.9839	-118.42804	(((Permit 4 of 4 for (3) new 2-story core and shell commercial office buildings.  New distribution and lighting inverters located inside parking garage supplying exterior loads.  Plan check for power.  Outdoor square footage charged under permit 1 of 4.Bldg permits for the (3) separate buildings are under the following permits:16010-10000-0393516010-10000-0393616010-10000-03937)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17033	16041-20000-45006	4751 E YORK BLVD	90042	14	156A223   143	5476020024	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Info Complete	01/31/2017 12:00:00 AM	ADDRESS	34.12255	-118.2118	Plan check for power and energy. Change of use from retail to restaurants + art gallery. Restoring tentant spaces to shell condition. New 800A service. T24: indoor - 435sqft; outdoor - 3,011sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17034	18041-10000-13112	1552 W ROCKWOOD ST	90026	13	135A207   285	5159013016	RD1.5-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.06355	-118.26143	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 46.5 KW. (2) inverters, (125) modules, (63) power optimizers. Permit Fees are $0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17035	13041-10000-03112	4301 N GRIMES PL	91316	5	165B125   216	2184031006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.14881	-118.52669	PV1 for single story house. [Inverter used: Fronivs Model#: IG PLUS 7.5] [Solar Module used: Trina Solar Model#:TSM-240-PA-05]. System size: 10.56 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17036	15041-10000-01070	12510 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	33.97839	-118.4121	Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps.Fire alarm variance submited. Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17037	14041-10000-14662	4125 S CRENSHAW BLVD	90008	8	114B185   323	5032002066	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	34.00937	-118.33544	PLANCHECK FOR TEMPORARY POWER. 600AMP 277/480 V SERVICE. Changes on plans include a 3/0 for secondary of transformer and physical protection for equipment. Not methane	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17038	14041-10000-23764	7303 N ETHEL AVE	91605	2	186B161   573	2327003020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.2031	-118.41829	PLAN CHECK FOR ENERGY ONLY FOR WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17039	17041-10001-26339	811 E TRACTION AVE UNIT #2A	90013	14	127-5A215  36	5163015008	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.0452	-118.23546	PLAN CHECK FOR TITLE 24 ONLY FOR - MODIFICATION OF LIGHTING SYSTEM ON 2ND FLOOR. REPLACING EXISTING LIGHTING WITH NEW LED LIGHTS AND REUSING EXISTING CIRCUITS.- TOTAL AFECTED AREA = 1674 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17040	16041-10003-19293	3013 E ASBURY ST	90065	1	147A217    79	5454031026	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.09855	-118.23019	8/15/16: Revised location of the MSP. All others remained the same.6/10/16:   Revised modules layout, all other remian the same.<<PV1, INSTALL 4.578 KW DC / 5.00KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER SPR-327-NE-WHT-D(1) INVERTR: SMA AMERICA SB5000TL-US-22>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17041	16041-20000-40989	1077 W 38TH ST	90037	8	117B197   508	5037015030	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.0174	-118.29395	Plan check for power and energy. New 5 story building - 4-story 140 unit apartment (10 typ. units) over ground level parking garage and office space. (2) 2500A services and (1) 1000A service. T24 - indoor: 80,830sqft ; outdoor: 39,286sqft. NEW 5 STORY  PARTMENT BUILDING : 4 STORY TYPE V-A ,  140 UNITS ABOVE TYPE 1-A GROUND LEVEL PARKIN GARAGE & OFFICE ( 138 LOW INCOME RENTAL  UNITS & 2 MANAGER UNITS)   . THE PROJECT DOES NOT PROVIDE HOUSING ON BEHALF OF ANY PUBLIC INSTITUION BUT IS PARTIALLY PUBLICLY FUNDED AND SUBJECT TO UFAS REQUIREMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17042	17041-20000-08225	3131 S HOOVER ST STE 1940	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.02611	-118.28472	Plan check for power and energy. Project site is a tenant space within an existing commercial building. Project scope is a change of use from retail to gym/tenant improvement. Total lighting area = 3,268 sq. ft.Note: Building application has been generated under 17016-20000-06116	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17043	18041-20000-31721	10749 N FARRALONE AVE	91311	12	207B101    54	2723006031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Issued	08/21/2018 12:00:00 AM	ADDRESS	34.26547	-118.61065	pv1install roof mounted pv system sized 10KW AC interconnected with msp.(34) solarworld 295 modules(34) optimizers P320(1) solaredge 10KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17044	18041-10000-18485	15120 W SUNSET BLVD	90272	11	126B129    21	4411001019	C2-1VL, R1P-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.04515	-118.52342	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17045	19041-10000-26379	11115 N LAUREL CANYON BLVD	91340	7	210B149   706	2613025053	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.2721	-118.44668	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17046	09041-20001-13618	19755 W VANOWEN ST #A-2-#A-28	91306		183B117   835	2135022005	(T)(Q)C4-1VL		Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka			Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			Corrections Issued	05/02/2011 12:00:00 AM	ADDRESS	34.19397	-118.56386	Revision to approved plans. Panels A2, A4, A6, A10, A14, A20, A24, A26, and A28 are future. Combine ckts from panels A10 with A8, A14 with A16, and A20 with A22.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17047	17041-10001-15339	10250 W SANTA MONICA BLVD #1830	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"First Time Tenant ""Rodd & Gunn"" Ste. #1830. : TENANT REVISIONS DELTA 3- Removed 16 ea tpe A luminaires and revised sheets E2.1, E3.1, E5.1 and E5.3 to reflect the changesPLAN CHK ONLY"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17048	16041-10004-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM			PC Approved	01/22/2018 12:00:00 AM	ADDRESS	34.04771	-118.46271	PC FOR CHAGNES TO APPROVED SET UNDER DELTA 10. CHANGES INCLUDES RELOCATION AND ADDITION OF RECEPTACLES, ADDED LIGHTS, REVISION TO PANELS SCHEDULES AND T-24 FORMS. THIS IS PLAN CHECK ONLY!	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17049	12041-20000-10668	6535 W FOOTHILL BLVD	91042	2	201A203   124	2570019008	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	07/12/2012 12:00:00 AM	ADDRESS	34.24569	-118.27427	TI change from bakery to goodwill store. Plan check for energy and emergency lighting. 3509 sq ft (2903 sq ft)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17050	14041-10001-30539	837 E 4TH PL	90013	14	127-5A215 207	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	06/14/2017 12:00:00 AM		Issued	06/14/2017 12:00:00 AM	ADDRESS	34.04401	-118.23553	04/12/16Changes to an approved set of plans. All changes are made under delta 1. Scope includes revising lighting fixture schedule, updating title 24 forms, revising circuits for CP-1 SFC-1 and CU-1, revising single line diagram to include fire pump conduit, updating load calculations for EMSB, and updating panels HA, LA, LB, EH1, LR1, EMSB.NOTE: fire pump scope of work under PCIS#15040-10000-05259 ((((Plan check for power and energy.  New 134,180 sq. ft. above ground 8 story parking structure.  Re-check list of equipment.Fire Alarm variance issued 11/04/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17051	19041-20000-46399	215 S CHADBOURNE AVE	90049	11	129B137    56	4406019008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.05325	-118.49141	PV1.  Installation of 8.14 kW DC roof mounted grid tied PV system with 9.8 kWh energy storage.  (22) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17052	12041-10000-07122	8155 W FOOTHILL BLVD	91040	2	204B193    66	2556022033	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Apartment			03/28/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.25986	-118.31096	Plan check for replacing existing fire alarm control panel, new smoke detector, and new pull section. Existing fire alarm system for apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17053	15041-20000-12938	11332 W DONA LOLA DR	91604	2	159B173   410	2380017025	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.13218	-118.37782	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17054	14041-20000-09159	5550 N TOPANGA CANYON BLVD SUITE 130	91367	3	174B101   285	2146007119	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.17162	-118.60554	Commercial office TI in a 3-story office building.  Title 24 plan check for changes to lighting system.  New fixtures in meeting room, rest of tenant space to have relocation of existing fixtures not to exceed 50% of total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17055	10041-10000-25428	259 S HAMPTON DR	90291	11	111B141   633	4286003010	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Info Complete	02/22/2011 12:00:00 AM	ADDRESS	33.99672	-118.47739	ADDITION & REMODEL OF AN (E) 1 STORY RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17056	11041-10000-20637	1701-1713 S PENMAR AVE BLDG 31	90291	11	111B149   320	4243001044	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.00271	-118.4575	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17057	16041-10000-13959	2006 S CHARITON ST	90034	10	126B173   791	4302034009	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.0403	-118.37795	PV1, rooftop solar installation using AC modules (10) SPR-E20-327-C-AC   3.2 kW AC.Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17058	16041-20000-24545	6819 N BAIRD AVE	91335	3	183B125   956	2126023007	(T)(Q)R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			07/13/2016 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.19449	-118.53746	Plan check for power and energy for 7 unit appartment Building with 600A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17059	16041-10000-33464	800 S FIGUEROA ST STE 1080	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	PC for power only to a high rise existing bulding. Work is being done on the 10th floor only. installing new lighting and power. total sqft = 2828.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17060	17041-20000-00849	5633 E YORK BLVD	90042	14	154-5A227  32	5478026027	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM			Reviewed by Supervisor	01/19/2017 12:00:00 AM	ADDRESS	34.11936	-118.1955	PLAN CHECK FOR POWER AND ENERGY.  A TWO STORY MIXED-USE BUILDING WITH SUBTERRANEAN PARKING. 2 STORY 22-UNIT MIXED USE. 25,549 SQFT INDOOR AREA. 7,884 SQFT OUTDOOR AREA. Fire alarm variance is on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17061	16041-10003-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM			PC Approved	05/30/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Attached to the revised plans is a list of changes ( delta 48 and RFIs 1325 & 1368 )PLAN CHECK ONLY(((((PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT. BUI;DING APPLICATION 16010-10000-04147	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17062	15041-10002-41798	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.08901	-118.34188	"PC FOR CHANGES TO APPROVED SET UNDER DELTA 8.SCOPE INCLUDES REVISION TO PANEL""RP"" TO REFLECT FIELD CHANGES. REDUCTION IN LIGHT FIXTURES TYPE ""LN3-B""  INSTALLED WITH UPDATED TITLE 24 FORMS. THIS IS PLAN CHECK ONLY!PERMIIT PULLED UNDER ORIGINAL."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17063	11041-10001-14042	15222 W VENTURA BLVD	91403	4	168B145   995	2276007058	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			06/05/2012 12:00:00 AM			PC Info Complete	06/27/2012 12:00:00 AM	ADDRESS	34.15331	-118.46466	NEW 5-STORY MIXED USE RESIDENTIAL AND COMMERCIAL BUILDING.  50 RESIDENTIAL UNITS WITH COMMERCIAL SPACE BELOW.  FULL PLAN CHECK.(((((((    50 FEEDERS CHANGING FROM al TO cu  ))))))))))))))))))) plan check only application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17064	15041-20000-05056	12354 W TIARA ST	91607	2	177B165   890	2340007003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.17824	-118.4026	"""0$ permit fees due to senate bill 1222 ""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 21.84 KW DC.(84) KYOCERA # KU2606XPA(1) FRONIUS IG PLUS A 7.5(1) FRONIUS IG PLUS A  10"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17065	16041-20000-12580	11817 W VALERIO ST	91605	2	186B169   660	2317017011	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.20494	-118.39111	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17066	15041-20000-00249	7644 N HINDS AVE	91605	6	186B169    97	2317006009	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2015 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.20973	-118.39093	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 5.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17067	18041-10000-13577	634 N KINGMAN AVE	90402	11	124-5A133 150	4408036007	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.03522	-118.50854	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND TWO ENERGY STORAGE SYSTEMS (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. CONISIT OF 24 MODULES(#SC325) AND A CENTRAL INVERTER (DELTA SOLIVIA 7.6) . SYSTEM SIZE IS 7.6KWac AND 7.8KWdc.SCOPE INCLUDES NEW LOAD CENTER (125A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17068	11041-10000-08512	8734 S BELLANCA AVE	90045	11	096B169   844	4125018007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	33.95765	-118.38038	UPGRADE OF ELECTRICAL SYSTEMS AT FUEL ISLANDS, CARWASH, AND CARWASH BUILDING REMODEL AT ENTERPRISE RENT-A-CAR.  CUSTOMER REQUESTS FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17069	11041-10002-15257	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	PIN	33.94363002	-118.42513364	T.I.  Federal Express Hangar.  1 out of 3 applications.  This application deals with the new 2-story modular unit that is to be permanently installed within the Federal Express hangar.  The modular unit is not state approved.   This plan shows the 2 panels pertaining to the modular unit, but these panels have already been charged on the power application (11041-10000-15257).  This plan also shows the lighting and power for the modular unit.  This application also deals with charging the new branch circuits and non-dwelling power equipment reflected on this plan set.  Title-24 calculations within the hangar and the new 2-story modular unit that is to be permanently installed is under 11041-10001-15257.  The power portion (single line diagram) of the project along with showing the lighting side of the office space that is to be remodeled is under 11041-10000-15257.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17070	17041-20001-28910	10964 W VENTURA BLVD	91604	2	162B173   572	2378007012	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1438.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.14	-118.3695	09/14/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for energy only. TI - change of use from retail to restaurant. New lighting (incl. emergency) - 1,088sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17071	17041-10000-20194	3400 E WHITTIER BLVD	90023	14	121-5A227 129	5188017030	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.02757	-118.20087	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17072	09041-10002-05357	2301 W BELLEVUE AVE 7th Floor	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM			PC Approved	06/14/2010 12:00:00 AM	ADDRESS	34.07417	-118.26931	REVISIONS TO PERMITTED SET OF PLANS- REMOVING THE STUDENT ROOM ( ROOM 706 ) AND MAY CONVERT TO A CHAPEL IN THE FUTURE; RELOCATING THE REST ROOMS; CHANGING A STORAGE ROOM  INTO A SOUND BOOTH; THE FLOOR PRINT REMAIN THE SAME WHILE CHANGING THE FUNCTIONS OF SOME AREAS. OVERALL, LIGHTING DENSITY  AND POWER REQUIREMENTS DECREASED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17073	18041-20000-27329	8620 N TAMARACK AVE	91352	6	195B169   430	2631018079	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Issued	11/05/2018 12:00:00 AM	ADDRESS	34.2283	-118.38502	Change of use from warehouse/office to hydroponic agricultural enterprise/office.  (E) 2000A 480Y/277V 3ph-4w and 400A 240/120V 1ph-3w services with new distribution.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17074	15041-10000-30449	3335 S FIGUEROA ST SUITE D	90007	9	120A203   503	5123009042	[Q]C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.02224	-118.28008	TENANT IMPROVEMENT TO (E) RESTAURANT (DoG Haus) .  NEW KITCHEN EQUIPMENT;plan chk is for TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17075	14041-10000-09247	7332 N VARNA AVE	91605	2	186B157   452	2328028001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.20389	-118.42458	Remove HID light fixtures and replace with new fluorescent fixtures. Total area 7915 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17076	16041-10000-37437	111 S THE GROVE DR	90036	4	138B177  1129	5512003036	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.0734	-118.35657	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENTS TO SECOND FLOOR OF EXISTING FARMERS MARKET SELF STORAGE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS24200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17077	17041-30000-43149	847 N VIA DE LA PAZ #101	90272	11	129B125   735	4412004022	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	34.04612	-118.52753	Plan check for Title 24 for coffee T.I. Total area: 775 sq ft. Building Permit number:17041-30000-35339	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17078	15041-10001-04917	11952 N DUNNICLIFFE CT	91326	12	216B125   135	2870021020	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	ADDRESS	34.28898	-118.53758	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 8.64 kWac (microinverter)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17079	16041-10000-29291	11400 W OLYMPIC BLVD 410	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM			PC Info Complete	09/01/2016 12:00:00 AM	ADDRESS	34.03666	-118.44346	T-24, PC FOR ENERGY ONLY. INTERIOR TENANT IMPROVEMENT TO EXISTING OFFICE SPACE.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2293 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17080	17041-20000-00811	4227 N LANKERSHIM BLVD	91602	2	165B177   886	2423026001	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.14659	-118.36379	Plan check for a fire alarm system for a commercial building. System consists of (1) FACP and (26) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17081	18041-20000-18474	7222 N FORBES AVE	91406	6	183B133    67	2226019007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.20175	-118.49881	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 3 kWac for a total system size of 6 kWac. Addition consists of (1) inverter, (10) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17082	17041-10000-45105	7900 W MELROSE AVE	90046	5	141B177   604	5527017001	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.0836	-118.36186	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17083	14041-10000-31414	835 E IMPERIAL HWY	90059	15	087A209   367	6072013022	RD2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Apartment			11/12/2014 12:00:00 AM			Reviewed by Supervisor	12/23/2014 12:00:00 AM	ADDRESS	33.93118	-118.25968	PV 1 System Size: 18.5kW with 2 inverters (Delta-solivia 7.6TL , (7.6kW)) and 66 modules (LDK SOLAR, LDK-280P-24) ROOF TOP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17084	13041-10000-01031	10311 S WESTERN AVE	90047	8	091-5A193 265	6058007017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Apartment			01/15/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	33.94282	-118.30934	installation of new fire alarm system for new 4 story appartment building. total of 166 devices and 2 new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17085	15041-20000-21013	14717 W CHATSWORTH DR	91345	7	210B149   863	2615015018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.2707	-118.45334	Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (38) micro-inverters, (38) modules, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17086	07041-10003-03752	120-130 S HEWITT ST	90012		129A215   194	5163003015	CM-1		Central City North	Historic Cultural			Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM			PC Approved	11/15/2011 12:00:00 AM	ADDRESS	34.04803	-118.23599	Modification to previously approved set of plans.  Removal of two notes and addition to notes to allow THQB series rated breaker, as requested by inspector.<<<<<COMBINE 2 EXISTING BUILDINGS TO BE SINGLE BUILDING.  CONVERT FROM EXISTING INDUSTRIAL USE TO 33 LIVE-WORK UNITS VIA ADAPTIVE REUSE ORDINANCE. ADD NEW MEZZANINES, NEW STAIR, NEW PARKING PLAN, CREATE NEW EXIT /LIGHT COURT.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17087	17041-10001-16619	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	CHANGES TO APPOVED SET OF PLANS - SCOPE ARE CLOUDED UNDER DELTA 3 - CHANGES INCLUDE ADDITION OF HALLWAY AND 2 NEW LIGHTS (2 SHEETS AFFECTED AND APPROVED)ORIGINAL PERMIT UNDER 17041-10000-16619OFFICE TENANT IMPROVEMENT  IN LEVEL 4. new lighting. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17088	14041-10000-32922	12458 N GLADSTONE AVE	91342	7	219B161   197	2525019058	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.29612	-118.41197	Plan check for T-24 only for T.I. Total area: 20263sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17089	12041-10001-06354	13488 W MAXELLA AVE	90292	11	105B153    78	4212004012	[T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	Plan check for new loads added. Delta 7 revision. FEDEX Office store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17090	19041-10000-04286	3470 S TROUSDALE PKWY	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.02202	-118.28393	INSTALL 24EA. 50W LED FILOUD LUMINAIRE COLOR LIGHT FIXTURE ON THE OUTDOOR AREA. T-24 ENERGY ONLY. PLAN CHECK ONLY.PERMIT: 18041-10000-18718	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17091	13041-10000-33298	3620 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.0213	-118.28935	permit to be pulled at EPC counter only. PC for energy only. TI TO MECHANICAL ROOM 5. EQUIPMENT REPLACEMENT. Less than 400A. emergency provided from generator. Located in USC's Seeley G Mudd Building (SGM).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17092	15041-10001-03356	500 WORLD WAY T05	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	CHANGES TO AN APPROVED SET, NOTE CHANGES ON DELTA 2. REDUCED LIGHT FIXTURES. Plan check for Title 24 only. Project space is retail. Space is located in Terminal 5 (Space 5U). Total lighting area = 160 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17093	19041-20000-53325	6600 N TOPANGA CANYON BLVD 1068-1070 A	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Info Complete	06/02/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. RELOCATION OF EXISTING PANELS, LOADS AND EQUIPMENTS. ENERGY AND POWER PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17094	15041-10000-29085	3261 W COUNTRY CLUB DR	90019	10	129B189   632	5081026011	R1-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.0496	-118.31337	+PV1. NEW ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 5KW. (20) MODULES-REC SOLAR REC275TP(1) INVERTER- SOLAREDGE TECHNOLOGIES: SE5000 (240V) W/-ER-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17095	16041-20000-21949	7945 N KEER DR	91335	12	189B125  1016	2102015089	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.2154	-118.53492	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17096	16041-20001-05208	215 N VERMONT AVE	90004	13	138B197   568	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.07493	-118.29195	Expedite per applicant request{{{{{{{Plan check for PV roof mounted system. System size: 112kW with 276 modules and 8 inverters(14kW) connected to 400A sub panelNote: Solar water Heater is included on the roof plan.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17097	15041-10000-15026	21355 W SHERMAN WAY SPACE 7226	91303	3	186B105   631	2111029001	(T)(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Expired	07/17/2017 12:00:00 AM	ADDRESS	34.20118	-118.5973	Energy plan check for an retail office T.I  with new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17098	11041-20000-03806	15034 W MAGNOLIA BLVD	91403	2	171A147    23	2263004011	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00, 1289.10	Electrical	Electrical	Apartment			02/28/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	06/20/2012 12:00:00 AM	ADDRESS	34.16455	-118.46081	PLAN CHECK POWER AND ENERGY FOR NEW 6 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17099	19041-10000-32063	3000 S ROBERTSON BLVD 3RD FLR	90034	10	123B169   884	4311033015	C4-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.03242	-118.39001	TI ON THE 3RD FLOOR. INSTALLING ABOUT 400AMP OF NEW LOAD, LIGHTING TRANSFORMER AND PANELS. AREA: 24,432 SQR FT. BULDING PERMIT: 19016-10000-25554	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17100	14041-10000-07180	1318 N NORTH SPRING ST #B-1	90012	1	136-5A217  91	5409006051	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.06632	-118.23289	T24, REMOVE EXISTING HID LIGHT FIXTURES WITH NEW FLORESCENT LIGT FIXTURES. TOTAL AREA 8858 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17101	18041-20000-48713	10851 N BEE CYN	91311	12	207B101   586	2723005063	(T)(Q)RA-1-K, A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.26749	-118.60732	Plan check for PV roof mounted system, system size: 13.86kW DC, 11.78kW AC with 42 PV Modules and 2 inverters(7.6kW) connected to 400A Service.Permit Fees $43.21 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17102	16041-10000-27053	12424 W WILSHIRE BLVD STE. 660	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.04135	-118.47058	PC for energy only, TI on (E) commercial buil.  (high rise building), scope of work on 6th floor. Total affected araea 367 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17103	10041-30000-00894	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	01/19/2010 12:00:00 AM		Permit Expired	07/26/2012 12:00:00 AM	ADDRESS	33.96577	-118.42406	New 30 hp Pump @ Loyola Marymoutn University.  Plan Check was requested by applicant.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17104	18041-10000-39955	5849 S CROCKER ST	90003	9	108B205  1217	6006029001	[Q]MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.98846	-118.26863	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17105	18041-20001-04597	1000 N ONEONTA DR	90065	1	153A221    91	5475012030	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.11484	-118.21481	Revision to approved set.  Addition of CTs to SLD design.  (((Plan check for the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17106	19041-20000-53522	1375 N VINE ST BLDG. A-2ND-4TH FL	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	06/05/2020 12:00:00 AM		Permit Finaled	05/17/2021 12:00:00 AM	ADDRESS	34.09602	-118.32703	Distribution, power, and lighting for multi-floor commercial tenant improvement (floors 2 thru 4).  Plan check for power and energy.   Associated building permit under 19016-10000-28216	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17107	16041-10000-24953	10534 W SANTA MONICA BLVD 1-9	90025	5	132B157  1071	4317004016	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			07/15/2016 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.05456	-118.42769	PC FOR A NEW METHANE MITIGATION SYSTEM (LEVEL IV) FOR A NEW 37 UNIT 5 STORY APARTMENT BUILDING. SCOPE INCLUDES 22 CONTROL DEVICES, AND CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17108	15041-20000-21217	24516 W EILAT ST	91367	3	177B085   605	2032023022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.17735	-118.65854	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.2 KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17109	15041-10000-25296	515 S FLOWER ST 2810	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN SUITE 2810. TOTAL SQUARE FOOTAGE 2463.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17110	15041-20000-37188	4849 N VAN NUYS BLVD	91403	4	169-5A151  98	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.15918	-118.44892	TI to existing commercial building. Medical office TI. Plan check for power and energy. Total sqft. 3,900.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17111	16041-10001-38452	201 S BROADWAY	90012	14	130-5A213  21	5149009019	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.05237	-118.24698	11/30/2016 Changes to an approved set to plans, Changes include re-connect feeder to existing meter and remove panels for desegregation. with 1 new panel. Changes apply to delta 2 only((((((Plan check for Title 24 only in existing space high-rise building T.I. Total area: 490 sq ft.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17112	16041-20001-13688	350 S HILL ST	90013	14	130-5A211 149	5149015024	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.05047	-118.24998	Revisions to approved plans for high rise building.  Floor configuration changes, reconfiguration of SLD.  All changes clouded and identified.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17113	19041-20000-41216	6151 N RADFORD AVE	91606	2	177B165  1102	2334011031	(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Apartment			10/10/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Closed	07/21/2020 12:00:00 AM	ADDRESS	34.18246	-118.3924	TEMP POWER FOR CONSTRUCTION, NEW 600A SERVICE, SCOPE OF WORK INCLUDES 3 MOTORS, 4  TRANSFORMERS, AND 5 PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17114	19041-20000-18545	10542 W CROCKETT ST	91352	2	192B177   804	2407004003	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.2201	-118.36112	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17115	17041-20000-25130	4678 N NATOMA AVE	91364	3	168A111    75	2174018009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.04	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.15488	-118.57933	pv1install roof mounted pv system sized 6kw intercnnected with msp.this system is an addition  to an existing pv system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17116	18041-10000-19347	333 N CROWN DR	90049	11	135B141   600	4403014005	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM			PC Approved	11/16/2018 12:00:00 AM	ADDRESS	34.06477	-118.48023	PLANCHECK only FOR NEW TWO STORY SINGLE FAMILY HOUSE WITH BASEMENT. PLAN CHECK OF 600 AMP SERVICE , LOADS, PANELS & GENERATOR .PERMIT UNDER BLDG  # 15010-30K-02125	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17117	19041-20000-35186	5460 N CORBIN AVE PV2	91356	3	174B117   535	2164009008	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.1701	-118.56232	PV1 PLAN CHECK FOR ADDITION TO EXISTING PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS NOW 14.805 KW DC/12.8 KW AC. SCOPE OF WORK CONSISTS OF (16) PV MODULES WITH POWER OTPIMIZERS, AND A 3.8 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17118	14041-20000-25344	8704 N MAYA PL	91343	12	195B141   732	2672012064	(T)RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.22867	-118.47702	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.9KW INTERCONNECTED WOTH MSP.(22) CANADIAN SOLAR MODULES CS6P-250(22) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17119	15041-10001-22094			11	132B137   407	4406009015	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	PIN	34.05712559	-118.49103568	PV1 10.07KW ROOF MOUNTED PV SYSTEM(38) KYOCERA #KU2656ZPA(2) INVERTERS PVI-5000-OUTD-US-Z-A, PVI-3.0-OUTD-S-US-Z-Afees per applicant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17120	19041-20000-50334	8064 N WILKINSON AVE	91605	2	189B165   199	2308021001	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.21757	-118.40401	Plan check for PV roof mounted system, PV system size: 10.9KW AC, 12.3KW DC with 30 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17121	15041-10000-26378	6201 W HOLLYWOOD BLVD ste 110	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Closed	02/12/2024 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC NEW FIRE ALARM SYSTEM 17 DEVICES. PARTIAL PERMIT FEES PAID UNDER APP # 15041-10000-17808	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17122	19041-20000-02890	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.24912	-118.34256	PC for PV. adding 13.5 kwh energy storage system. and 1 load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17123	11041-10000-10529	9135 N INDEPENDENCE AVE	91311	12	198B105   166	2746009044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.23675	-118.59135	New sprinkler monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17124	12041-10000-24874	3650 W MARTIN LUTHER KING, JR BLVD #FC-13	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	FIRST TIME TENANT FOR YOGURT STAND (#FC-13) INSIDE NEW FOOD COURT ADDITION AREA. EPC FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17125	13041-10000-01150	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM			PC Approved	01/16/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check T24 Energy/emergency lighting for Virgin American Airline offce renovation at Terminal #3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17126	16041-10000-21317	1133 N VINE ST	90038	13	144B185   591	5533007023	[Q]C2-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.09171	-118.32698	NEW FIRE ALARM SYSTEM WITH 379 FA DEVICES AND AND 8 FA PANELS. FOR A NEW 5-STORY  HOTEL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17127	11041-10000-06952	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	ADDING A NEW CENTRAL PLANT TO A HIGH RISE BUILDING.  ADDING VARIOUS NUMBERS AND SIZES OF VFD'S, MOTORS, PUMPS, CHILLERS, ONE TRANSFORMER, 2 PANELS, 1 SWITCHGEAR, AND FEW LIGHTING CIRCUITS.  PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17128	13041-20000-12458	6320 N CANOGA AVE SUITE 150E	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.18499	-118.59722	RENOVATON OF EXISTING OFFICE SPACE. NEW LIGHTING FIXTURES. NEW CONNECTED LOAD LESS THAN 400 A. PC FOR ENERGY ONLY T24. PERMIT TO BE ISSUED UNDER THIS APPLICATION. TOTAL AREA 7541 SQ FT. WORK DONE IN SUITE 150E	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17129	18041-10000-41990	2910 W SAN FERNANDO ROAD	90065	1	153A213   165	5457004007	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.11174	-118.24396	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17130	10041-10001-22559	4501 W COLORADO BLVD BLDG  8	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/20/2011 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	INSTALLATION OF MV  EMERGENCY GENERATOR AND ASSOCIATED ATS TO SUPPLY EM LOADS IN BLDG 8NEW 2-STORY MANUFACTURING FACILITY WITH PARTIAL BASEMENT AND TWO EQUIPMENT PLATFORMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17131	14041-10000-25104	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			Corrections Issued	09/12/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	Title 24 (part 6) plan check only.  Total area = 24,520 sq. ft.Interior office TI including lighting and recepticles.  Highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17132	15041-10000-35665	3081 W 12TH PL #1234-A	90006	10	129B193  1106	5080011002	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.04822	-118.30846	PC for energy only. T-24, TI to an existing commercial building (korean food institution). Adding new lighting and receptacles. Sq ft = 1950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17133	17041-20000-44177	4551 N CONCHITA WAY	91356	3	168B117   531	2178028002	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.15384	-118.55926	PV1.  Install 17.64 kW roof mounted grid tied PV system.  (49) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17134	16041-10000-45662	5263 W ADAMS BLVD	90016	10	123B177   911	5043003018	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.03266	-118.35751	PC FOR POWER AND ENERGY. NEW 3 STORY MIXED USE,  14 UNIT   APARTEMENT BUILDING WITH ONE LEVEL SUBTERRANEAN PARKING GARAGE. ( TOTAL  3 STORY BUILDING). SERVICE 1200A , 208/120V, TOTAL AREA 17200 SQ FT.B# 16010-10000-05038	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17135	19041-10000-27424	3547 S BARRINGTON AVE	90066	11	114B157   191	4249017041	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.01179	-118.43042	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.48KWdc / 3.00KWac. (12)MODULES- REC 290TP2 BLK(12)SOLAREDGE P320(1)INVERTER- SOLAREDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17136	16041-10000-24384	100 N LA BREA AVE	90036	5	138B181   827	5513003016	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.07377	-118.34383	PC FOR ENERGY ONLY. REPLAEMENT OF HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 6152 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17137	13041-10000-34506	139 S GEORGE BURNS ROAD	90048	5	138B169   439	4334005036	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.07422	-118.38178	Addition of a 150 kva xfmr, 600 amps panel 16 ev charging  units , demand verfied on customers  I Phone from DWP st less than 600 KW with unity power factor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17138	19041-20000-44674	21160 W CALIFA ST	91367	3	174B105    17	2149002019	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.17691	-118.5929	Plan check for new fire alarm system, new fire devices: 46 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17139	16041-10000-40113	150 W 12TH ST	90015	14	126A207   234	5139025028	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.03831	-118.26077	PC FOR T24 ENERGY ONLY. REPLACING EXISTING LIGHTING FIXTURES FOR NEW ENERGY EFFICIENT LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17140	15041-10000-40206	2049 S CENTURY PARK EAST #800S	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI on (E) office space, Suite 800. PC for Energy only, Total area 11,305sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17141	15041-10002-22722	18559 W VANOWEN ST	91335	3	183B121  1129	2126023003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM			PC Approved	05/25/2016 12:00:00 AM	ADDRESS	34.19399	-118.53812	PC FOR A LOST SET OF PLANS. PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(19)MODULES-SUNPOWER SPR-327NE-WHT(2)INVERTERS-SMA SB3000TO-US-22NOTE: PERMIT PAID UNDER PCIS#15041-90000-22722(((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17142	10041-10000-06885	253 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			04/15/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04983	-118.2258	Solar voltaic system installed on the roof of the building.  Consists of 8 modules, 8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17143	16041-10000-15226	505 W FLORENCE AVE	90044	8	102B201   855	6013024045	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.97482	-118.2832	TI to an (E) McDonalds, install new light fixtures and receptacles. PC for T-24 only. Total area: 4,555 sq. ft (indoor+build. facade)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17144	17041-10000-20358	4501 W COLORADO BLVD SFWh-B7	90039	13	162B205    19	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.14246	-118.2705	Plan check for power and Title 24.  T.I. within building 7 for computer room, electrical room, equipment room, validation lab, and dry supplies storage room.  Convert portion of existing storage area in San Fernando Warehouse (SFWh) to new electrical room.  Disconnect existing panels and reconnect to new distribution boards.  No change of use.  Lighting area = 2,655 sq. ft.       Building permit #17016-10000-16114	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17145	13041-20001-35447	17402 W CITRONIA ST	91325	12	201B129   341	2755008029	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.24553	-118.51381	((EXPEDITE FEES))PV1 LF TRANSFORMER SYSTEM. TOTAL SYSTEM SIZE28KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17146	11041-20000-00522	17777 W VENTURA BLVD # 100	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	Ti unit # 100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17147	18041-20000-16004	10934 W PEACH GROVE ST	91601	2	168B173   318	2421014027	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Apartment			05/01/2018 12:00:00 AM			Reviewed by Supervisor	12/07/2018 12:00:00 AM	ADDRESS	34.15891	-118.36916	Plan check for power and energy. Project site is a 3-story, 6-unit apartment building over 1 level of basement parking garage. Work includes an 800 Amp service and a total lighting area of 8,500 sq. ft.Note: Building application has been generated under 18010-20000-00193	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17148	15041-10000-17818	8631 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.07373	-118.38036	NEW FIRE ALARM SYSTEM  FOR CEDAR - SINAI OFFICE TOWER. CORE AND SHELL .TWO BUILDING 8631 AND 8635 3RD ST CONNECTED WITH  BRIDGE. 1060 FA DEVICES, 7 CONTROL APNEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17149	19041-20000-49283	1848 N REDESDALE AVE	90026	13	145-5A205 249	5431037022	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.09266	-118.26781	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS AND (2) AC COUPLED ENERGY STORAGE UNITS INTERCONNECTED THROUGH GENERATION PANEL. TOTAL PV SYSTEM SIZE IS 7.59KWDC AND 7.36 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17150	15041-10000-05294	2155 E 14TH ST STE. B	90021	14	120A215    83	5167009013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.02398	-118.23471	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  CHANGES TO EXISTING LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 6948.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17151	13041-20000-13418	7038 W SUNSET BLVD	90028	4	147B181   698	5548017023	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			Reviewed by Supervisor	06/12/2013 12:00:00 AM	ADDRESS	34.0978	-118.34294	T.I. for an existing restaurant with a 1.000 sq ft addition.  Occupancy load is 389.  Place of assembly.  Full Plan Check required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17152	16041-10000-35849	2626 W COLORADO BLVD	90041	14	163-5A219 162	5682002024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.14192	-118.22342	PC FOR REPLACEMENT FIRE ALARM SYSTEM AS NEW. PROVIDING NEW PANEL AND DEVICES THROUGHOUT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17153	12041-10000-31128	6101 W 75TH PL	90045	14	102B169   395	4106005011	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	33.97233	-118.39194	PV1 1 STORY HOUSE 14 MODULES [MODULES: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17154	17041-10000-04714	5220 E ITHACA AVE	90032	14	139-5A235 421	5217020025	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.07451	-118.17239	PLAN CHECK PV ROOF MOUNTED SYSTEM USING 12 MODULES AND CENTRAL INVERTER 3KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17155	14041-20000-19108	9038 N ORION AVE	91343	7	195B145    26	2654002***	(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.05	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Expired	08/18/2016 12:00:00 AM	ADDRESS	34.23495	-118.47181	pc for replacement of fire alarm control panel and addition of 6 devices. check ldoad calcs and placement of new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17156	16041-20001-17070	2929 S QUEENSBURY DR	90064	5	126B161   502	4316001005	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.03857	-118.40617	Expedite per applicant request. {{{{{{Plan check only  for PV roof mounted system. System size: 7.6kW with 27 modules and 1 inverter(7.6kW)Inspector request for plan check due to inverter is in garage closet and the conductor is running in the attic.Note: Permitted application Number: 16041-90000-11180}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17157	19041-20000-41061	11881 W TERRA VISTA WAY #115	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17158	15041-20000-34149	5329 N BLUEBELL AVE	91607	2	171B161   173	2346021024	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Refund in Progress	01/24/2017 12:00:00 AM	ADDRESS	34.16751	-118.41064	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC UISNG SINGLE INVERTER SYSTEM. USING TOTAL OF 28 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17159	16041-20000-05746	4817 N NATOMA AVE	91364	3	169-5A111  95	2166025003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.15811	-118.57931	Plan check for PV roof mounted system. System size: 10.0kW with 52 modules and 2 inverters(5.0kW and 5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17160	16041-20000-34240	2631 W SOUTHWEST DR C	90043	8	105B189  1430	4007020017	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	33.9813	-118.3224	ti to an existing commercial space.  plan check for energy only.  total square footage 600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17161	16041-10000-26853	9200 S FALMOUTH AVE	90293	11	093B157     3	4119006912	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	08/23/2021 12:00:00 AM	ADDRESS	33.95226	-118.43281	FULL PC FOR POWER AND ENERGY. INSTALLATION OF PUMP BUILDING FOR STORM WATER PROJECT. METHANE ZONE. 400A SERVICE 600A SWITHCHGEAR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17162	10041-10000-05074	701 S HILL ST BASEMENT	90014	9	129A209   229	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/19/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Expired	12/20/2012 12:00:00 AM	ADDRESS	34.04582	-118.25475	Relocate water treatment room for  jewelry manufacturing tenants in a high rise building ; plan check is required by the applicant ; room is relocated from the 2nd floor  to the basement area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17163	17041-20000-41435	11911 W SAN VICENTE BLVD SUITE 100	90049	11	129B145    78	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.05295	-118.47002	TI to commercial restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17164	16041-10000-28717	12100 W WILSHIRE BLVD STE 1625	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	T. I. FOR STE 1625 ON 16TH FLR NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17165	18041-10002-15617	4500 N WOODMAN AVE	91423	4	168B157   929	2360002030	R1-1-RIO, R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.15306	-118.43102	"DELTA 4 CHANGES TO APPROVED PLANS ON ""E"" PAGES 1.1, 4.0, 4.1 & 4.2 FOR ADDING OCCUPANCE SENSORS.<<<PC FOR T-24 ENERGY ONLY. TENANT IMPROVEMENT. SCOPE INCLUDES NEW PANEL, LIGHTING AND RECEPTICAL. TOTAL AFFECTED AREA IS 12306 SQ.FT.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17166	16041-20001-19993	5555 W MELROSE AVE 1ST FLOOR	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM			PC Approved	07/22/2016 12:00:00 AM	ADDRESS	34.08363	-118.32191	Revisions to approved set of plans.  Changes to lighting system.  Change of emergency supply from battery backup to emergency inverter.  (((PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 1ST FLOOR OFFICES AND STORAGE.  6675 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17167	10041-10001-24390	10250 W SANTA MONICA BLVD STE# 185	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Expired	03/08/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	REVISIONS TO PERMITTED SET OF PLANS INCLUDE NEW PANELBOARD, CIRCUITS AND TRANSFORMER))))))))))TENANT IN RETAIL STORE -SONY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17168	15041-10002-04180	7000 W WORLD WAY WEST 24R-6L	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Expired	09/19/2017 12:00:00 AM	PIN	33.93847109	-118.41935625	Medium Voltage. Change to approved set by relocating the light fixtures in the Taxiway runway ( BB, W, V) 24R-6L .  Original plan checker is under M.Z(((Replace airfield lighting (FAA) on runway.  Runway 24R-6L)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17169	11041-10001-23844	872 N VIA DE LA PAZ	90272	11	129B125   634	4412003003	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			01/11/2012 12:00:00 AM			PC Approved	01/11/2012 12:00:00 AM	ADDRESS	34.04679	-118.52701	Type k luminaire changes to a 50W Par38  ; changes are shown  on the Lighting plan and compliance forms adjusted PLAN CHK ONLYchange of use to restaurant/yogurt shopplan chk is for title 24 onlyNOTE MAY REQUIRE COMPLETE PLAN CHK AS NEW LOAD IS NEAR 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17170	11041-10000-15650	1847 N KINGSLEY DR	90027	13	150A195   185	5544010016	R3-1	Central	Hollywood	Greater Griffith Park		1904.01	Electrical	Electrical	Apartment			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Expired	08/19/2013 12:00:00 AM	ADDRESS	34.10491	-118.30367	REPLACEMENT OF AN OLD NON-WORKING FIRE CONTROL PANEL WITH NEW COMPATIBLE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17171	13041-10000-30137	22400 W LULL ST	91304	12	186B101   106	2013019017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.209	-118.61505	PV1, Install 6.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 27 modules: Fronius IG Plus V 7.5.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17172	17041-10000-27702	515 S FLOWER ST 1220	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	TITLE 24 PLAN CHECK FOR TI (NON BEARING INTERIOR PARTITIONS- OFFICE SPACE). TOTAL AFFECTED AREA = 1915 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17173	17041-20000-23042	1941 S PONTIUS AVE	90025	5	126B153   406	4323025026	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.04305	-118.44136	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. 4343 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17174	17041-10000-42792	13382 N AZORES AVE	91342	7	225B157   949	2510002045	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.31488	-118.42939	PV1 6KW roofmounted system with (1) 6KW inverter, (23) modules and solaredge P320 Power Optimizer interconnecting through the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17175	18041-10000-08044	14062 N BALBOA BLVD	91342	7	228B137   186	2603007027	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.32065	-118.4882	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 65475 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17176	18041-10000-48425	100 E VENICE WAY	90291	11	106-5A145  74	4238014010	R3-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Issued	12/21/2018 12:00:00 AM	ADDRESS	33.98722	-118.47143	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17177	16041-10000-21344	1137 W 6TH ST	90017	1	132A207   259	5152001003	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.05466	-118.26311	T-24, PC FOR ENERGY ONLY. TI TO A EXISTING  2-STORY COMMERCIAL BUILDING. BUILDING WILL BE REFURBISHED FOR NEW OFFICE SPACE. SCOPE INCLUDES A NEW 400A DISTRIBUTION BOARD, FOUR NEW PANELS, NEW LOAD EQUIPMENT, AND NEW LIGHTS/RECEPTACLES. TOTAL AFFECTED AREA IS 10929 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17178	16041-10002-18570	6201 W HOLLYWOOD BLVD #104	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Issued	09/19/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	Changes to approved set of plan, noted under Delta -5 Only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17179	16041-10000-37782	2350 S MINER ST PV	90731	15	009B201    59	7440037903		Harbor				9800.31	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	33.72283	-118.27633	PERMIT FEE IS $0.00 DUE TO SENATE BILL 1222.PV 2 COMMERCIAL ROOFTOP SOLAR. PC FOR TOTAL OF 3819 MODULES AND 14 CENTRAL INVERTERS. INTERCONNECTING TO NEW DWP SERVICE FOR SOLAR ONLY. THIS IS FEED IN TARRIF PROJECT (FIT). LOCATED IN METHANE ZONE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17180	14041-20000-20698	18314 W OXNARD ST	91356	3	177B125   690	2157002131	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Closed	08/25/2014 12:00:00 AM	ADDRESS	34.17993	-118.53131	TI of (N) office spaces in (E) warehouse tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17181	19041-10000-42629	4707 S BROADWAY	90037	9	112-5A203 441	5110010034	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.00075	-118.2786	T-24, PLAN CHECK FOR ENERGY ONLY TO AN (E) SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ FOOTAGE: 2088 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17182	13041-10001-30271	2903 W PICO BLVD	90006	10	129B193  1273	5080027012	[Q]C2-2	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.04736	-118.30334	][][]EXPEDITED PER APPLICANT REQUEST ][][]PV2, ROOF-MOUNTED SOLAR INSTALLATION IN A COMMERCIAL BUSINESS BUILDING. INTERCONNECTING WITH 225A MAIN BUS. NEW 150A LOAD CENTER WILL BE USED. SYSTEM SIZE 16.5 KW DC, WITH (66) MODULES (HANWHA HSL60P6-PB-4-250QB) WITH (2) TRANSFORMERED INVERTERS (SUNNYBOY; SB7000-US).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17183	16041-10000-19901	1641 N IVAR AVE	90028	13	148-5A187 207	5546008022	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.10097	-118.3283	PC FOR SERVICE UPGRADE TO EXISITING BUILDING. OTHER WORK BEING DONE UNDER SEPARATE PERMITS. THIS PERMIT TO COVER SERVICE AND DISTRIBUTION ONLY. PC FOR POWER. SERVICES RECONNECTING TO EXISTING EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17184	19041-10000-52701	739 W 124TH ST	90044	15	081B197   103	6117011011	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	33.92019	-118.28825	NEW PV1 ROOFTOP SOLAR SYSTEM CONSIST OF 28 MODULES (Q-CELL 300), 28 OPTIMIZERS ( SE P320) AND ONE CENTRAL INVERTER (SE6000H-US). SYSTEM SIZE IS 8.4KWDC AND 6KWACCOMPLY WITH DEPARTMENT ORDER effective date10/02/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17185	15041-20000-20331	14942 W VENTURA BLVD	91403	4	166-5A147  26	2276004024	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.15244	-118.45888	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,392 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17186	17041-20000-18543	10701 N LIMERICK AVE	91311	12	207B109   322	2707024019	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.2647	-118.58288	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER STANDARD PLAN. SYSTEM SIZE: 9.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17187	15041-10000-38393	5700 N CANOGA AVE 2nd Flr	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.17365	-118.59715	Energy plan check for an office T.I located in the 2nd fllor of a commercial building. Scope of work located inside a few offices with new lighing, and receptacle; total area is 2920-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17188	14041-20002-01712	442 S VIRGIL AVE	90004	13	135A201   230	5077001039	(Q)CR-2	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			04/11/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	PIN	34.06557536	-118.28662708	Change of service and meter equipment to different manufacturer.  Verification of different series rated combinations.  Delta-3 changes only - sheets E-18 and E-19(((New 5-story apartment over 2-level parking garage with 74 units locate in Methane Zone.  New 2000A service, panels, branch circuits, and lighting.  Plan check for power and energy.Note: Variance to separate fire plans submitted on 6/30/14.  Methane Certificate of Compliance and Conduit Seal Detail attached with the plans.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17189	17041-10000-25102	1110 S WESTERN AVE #102	90006	10	129B193   694	5080010048	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Info Complete	07/25/2017 12:00:00 AM	ADDRESS	34.05041	-118.30886	PC fot T24 only for TI.  Total area 1400 sqft. Installing new lights and circuits  in existing panel. 17016-10000-19816.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17190	15041-10000-26877	200 WORLD WAY TERM 2-ARRV  LEV1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	"TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2ARRV  LEV 1  SPACE 282PLAN CHK IS FOR TITLE 24 by adding fixuture "" L4 "" to the newly approved permit."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17191	14041-20000-23433	11721 W RUNNYMEDE ST	91605	2	186B169   540	2317010020	C2-1VL, R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			08/27/2014 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.20585	-118.38836	New 4-story, 43 unit apartment over subterrean parking garage.  Power and energy plan check - 2008 Building Energy Efficiency Standards.  Fire alarm variance to be filed before permit to be issued.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17192	16041-20000-30241	19538 W BLACKHAWK ST	91326	12	204B117   174	2708004003	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.25764	-118.55931	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 7 kWac and consists of (28) modules, (28) micro-inverters, (3) load centers, and (1) battery system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17193	11041-10000-20745	2616 S HOBART BLVD	90018	8	123B193   684	5053012900	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.03207	-118.30768	ALTERATIONS AT THE ART CENTER LOCATED INSIDE A BUILDING WHICH ONCE HOUSED  ENGINE HOUSE NO.18 NEW SERVICES,PANEL BOARDS AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17194	16041-10001-06803	7314 S AVALON BLVD BODY-SHOP	90001	9	102B205  1099	6023008004	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	PIN	33.97335974	-118.26484803	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. REVISED FLOOR PLAN TO SHOW OFFICE SPACE. PROVIDED UPDATED T24 DOCUMENTS. THIS IS PC ONLY. PERMIT ALREADY ISSUED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17195	17041-10001-45915	5401 N LANKERSHIM BLVD	91601	2	171B173    55	2350012031	C2-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM			PC Approved	03/21/2019 12:00:00 AM	ADDRESS	34.16918	-118.37756	Plan check for change to approved set by updating new fault current due to the change of utility, relocating fire pump room,update feeders, updating lighting plan and minor ckts change on the floor plan. All changes under delta-Pc1. (((Plan check for power and energy. Project site is a new 7-story, mixed-use building: 5 levels of residential (totaling 127 units) over 2 levels of commercial with two levels of subterranean parking garage. Total lighting area = 150,098 sq. ft.Note: Building application has been generated under 17010-20000/20001-03994)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17196	16041-10000-10499	4357 W WILSHIRE BLVD	90010	4	132B189    16	5505022013	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.06198	-118.32315	PC FOR A NEW FIRE ALARM SYSTEM TO AN EXISTING MUSEUM. SCOPE INCLUDES 1 FA PANEL, 248 FA DEVICES, AND 1 COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17197	15041-10002-07589	123 S FIGUEROA ST	90012	14	132A211     6	5151001026	C2-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.05725	-118.25278	11/21/16Changes to an approved set of plans.  Changes include adding emergency lights for commercial space.Note: Permit is paid under PCIS#15041-10000-07589	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17198	18041-10000-07776	333 S GRAND AVE 9th-Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	FULL PLAN CHECK (POWER AND ENERGY) FOR A T.I. ON 9TH FLOOR OFFICE BUILDING: REUSING ALL EXISTING PANELS ON THE 9TH FLOOR, HOWEVER (121) NEW CIRCUITS ARE ADDED. TOTAL AREA: 20,276 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17199	12041-10003-30853	232 E 2ND ST	90012	14	129A213   468	5161024011	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Closed	11/14/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	07/29/16Changes to an approved set of plans. All changes are clouded under delta 21. Changes include adding HVAC equipment on the floor plans, and panel schedules; revising the single line diagram with an additional elevator, and revising load calculations. NOTE: Changes are made under sheets E0-13B, E0-20B, E5-0, E5-7, & E5-8 according to applicant.((((07-22-2015 Changes to an approved set of plans. Changes include the addition of (3) panels and associated loads. All changes have been clouded and marked Delta 9.[[[[[Revisions to approved set. THERE IS A CHANGE OF ENGINEER ON RECORD. THIS PLAN CHECK TO TO SUPERCEED THE PREVIOUS APPROVED SET OF PLANS.  (((Construct 5-story,  240-unit apartment with retail over garage, no disabled access.  Located in methane buffer zone. title 24 included, emergency lighting.)))]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17200	14041-10000-10444	412 S LAKE ST	90057	1	135A203   364	5154030022	(T)R4P-2	Central	Westlake			2088.01	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.06251	-118.27419	SERVICE UPGRADE AND REDOING ALL THE WIRING FOR EXISTING APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17201	16041-10002-16550	17383 W SUNSET BLVD	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.03917	-118.55529	02/03/2017 Changes to an approved set of plan. Changes include adding inverter details on the lighting floor plans. All changes are clouded under Delta 2. Note: Permit is paid under PCIS#16041-10001-16550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17202	19041-10000-51307	9425 W SIERRA MAR PL	90069	4	147B165   520	4392018038	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.09605	-118.39541	(E-PLAN) - 0$ FINAL FEES PER AB1414CHANGES TO AN APPROVED SETCHANGES INCLUDE RELOCATION OF EQUIPMENT AND REDUCING AMOUNT OF MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17203	19041-20000-46090	15455 W SAN FERNANDO MISSION BLVD	91345	7	210B145   128	2664007024	(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.27207	-118.46923	Installation of new FACP/elevator supervisory control panel with (7) signaling line devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17204	13041-10000-36268	1182 S CROCKER ST	90021	14	123A211   487	4243011032	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.0331	-118.25146	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 406 SQ FT. REPLACING TOTAL OF 3 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17205	18041-10000-44620	3450 S SAWTELLE BLVD	90066	11	117B157   315	4249031007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.01796	-118.42468	emergwncy lighting in corrdiors on 4 floors of  buildings  A;B;C;DPLAN CHECK FOR POWER  ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17206	11041-10001-22381	350 E 1ST ST	90012	14	129A215   347	5161017022	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/06/2011 12:00:00 AM	ADDRESS	34.04935	-118.23978	REVISIONS TO THE LIGHTING SYSTEM- TYPES C AND F LUMINAIRES HAVE CHANGED((((((((TENANT IMPROVEMENT IN PIZZA SHOP PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17207	18041-20000-44143	21650 W OXNARD ST STE 1555	91367	3	177B105    83	2146006042	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.17901	-118.60107	TI FOR AN OFFICE SPACE  IN A HIGH-RISE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL AFFECTED AREA IS 3099 SQ.FT. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17208	18041-10000-11737	200 N ROCKINGHAM AVE	90049	11	132B137   293	4406008006	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	05/25/2019 12:00:00 AM	ADDRESS	34.05882	-118.49112	**Zero permit fee per CA Senate Bill 1222**PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 36KWdc / 28KWac.(100)MODULES-LG LG360Q1C-A5(100)MICROINVERTERS-IQPLUS-72-X-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17209	10041-10001-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Addition and alteration to the TBIT.  The Core- Referenced as Core design Notice-103 in which each sheet and change is noted. Permit for branch circuits and additional 10 inspection trips (Per inspector)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17210	13041-10000-27050	17010 W GLEDHILL ST	91325	12	198B133   110	2692022038	RE9-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.24224	-118.50295	PV1. ROOF MOUNTED SOLAR ARRAY. 1 STORY HOUSE. POWER OPTOMIZERS(24) TRINA SOLAR 285 MODULES(24) SOLAREDGE OP300-MV(1) SOLAREDGE SE6000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17211	17041-10000-40876	2121 S AVENUE OF THE STARS 22ND FLR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM			PC Info Complete	11/13/2017 12:00:00 AM	ADDRESS	34.05554	-118.41342	PC FOR T-24 FOR OFFICE TI. INSTALLING ONE NEW PANNEL, NEW EQUIPMENT RECEPTICALS AND LIGHTS, NEW LOAD IS LESS THAN 200A. TOTAL AREA 1189 SQ. FTB# 17016-10000-22945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17212	17041-10000-04763	4831 S GRAMERCY PL	90062	8	111B189  1078	5015013021	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	33.99901	-118.31397	CHANGING OUT OLD FIXTURES FOR MORE ENERGY EFFICIENT. PC FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA IS 19675 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17213	19041-20000-35563	2137 N BRAWLEY ST	90032	14	136-5A233 115	5216002038	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2016.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.06906	-118.17817	Plan check for PV roof mounted system, PV system size: 6.6KW DC,  5.61KW AC with 20 PV modules and 1 inverter(6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17214	19041-10000-44530	12424 W WILSHIRE BLVD	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	03/05/2021 12:00:00 AM		Permit Finaled	01/19/2023 12:00:00 AM	ADDRESS	34.04135	-118.47058	TENANT IMPROVEMENT. PC FOR T-24 ENERGY ONLY. TOTAL AFFECTED AREA  7705sqft. (INDOOR & OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17215	13041-10000-07306	4211 S CENTRAL AVE 1st Floor	90011	9	114A209   123	5115019032	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Apartment			03/21/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.00718	-118.25675	TI for an apartment building's common area and lobby on grade level floor.  Requires Title 24 Part 6 compliance plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17216	15041-20000-30770	303 S UNION AVE 1st Floor	90017	1	133-5A205 120	5153003036	C2-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.06077	-118.26819	Title 24 plan check only.  Total area = 7,815 sq. ft.     T.I. to existing office space.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17217	11041-10000-02363	12232 W OSBORNE PL	91331	7	207B165   247	2537001032	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Apartment			02/07/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.26094	-118.39991	NEW 59 UNIT APARTMENT BUILDING (SOUTH BUILDING).  BUILDING ADDRESS IS 12232, NORTH BUILDING (12230) WILL BE SUBMITTED SEPARATELY.  FULL PLAN CHECK.   Electrical inspector to obtain completed LTG-2A and OLTG-2A forms from contractor prior to final, in accordance with section 134 of the 2008 energy standard.  A variance to separate the electrical and fire alarm plan check was submitted by the electrical engineers on May 17, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17218	14041-20002-15626	4131 N ELLENITA AVE	91356	3	165B117   459	2180005012	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.14508	-118.55917	Plan check only,  customer down size from (43) module and (2) inverters to (32) modules and (1) inverter base on plan check number: 14041-20000-15626Note:  Plan check fee is 0.00 due to Senate bill 1222 from 2012(((New roof mounted PV system with 300W Optimizers, and 6KW and 3.8KW transformerless inveters.  Total system size is 11KWdc.  Note: Permit is $0.00 due to Senate Bill 1222 from 2012)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17219	19041-20000-39271	18948 W GRANADA CIR	91326	12	216B121   601	2872009030	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.2849	-118.54656	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. 14.08KW DC/11.4 KW AC. SCOPE OF WORK CONSISTS OF (44) PV MODULES WITH OPTIMIZERS AND A 11.4KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17220	13041-10000-25244	8463 N PINELAKE DR	91304	12	192B093    98	2005015008	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.223	-118.63735	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 9.75KW DC ON CENTRIAL INVERTER STANDARD PLAN IN A 2-STORY HOME. COMBINER BOX IS USED. (39) TRINA #TSM-250(1)FRONIUS - #IG V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17221	18041-20000-44933	17638 W VANOWEN ST	91406	6	180B129    47	2229013026	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.19366	-118.51761	Change of use from retail to restaurant.  Plan review for Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17222	16041-10001-03507	1555 S ROXBURY DR	90035	5	129B165   417	4307012018	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.05079	-118.40093	02/03/2016DERATE OF THE MAIN BREAKER, PC FOR DERATE ONLY AND MISC. PERMIT FOR DERATE. PERMIT FEES WERE PAID UNDER EXPRESS PERMIT #16041-90000-03507.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17223	16041-10000-17596	423 W E ST	90744	15	030B205  1071	7418002013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	33.77548	-118.26697	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.68KWdc / 5.0KWac.(18)MODULES-260W HYUNDAI HIS-260RG(18)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE5000-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17224	11041-20000-05251	8700 W BEVERLY BLVD #6065-6066	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM			PC Info Complete	03/17/2011 12:00:00 AM	ADDRESS	34.07666	-118.3805	Plan check T24 Energy for remodeling of existing lab and office (#6065-6066) at the Cedars Sinai Davis Research Building. No patient care area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17225	17041-30001-38698	633 W 5TH ST Suite 5700	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			Ready to Issue	02/05/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	01-25-2018 Changes to an approved set of plans. Changes include replace lighting fixture with different type of lighting fixtures. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17226	13041-10000-08504	770 W WILSHIRE BLVD 2ND FLOOR	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.04914	-118.25811	T24 FOR 9 STORY OFFICE SPACE, SCOPE OF WORK ON THE 2ND FLOOR. HIGHRISE.10940 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17227	15041-10000-27412	505 W 62ND ST	90044	9	105B201   859	6004025031	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			Reviewed by Supervisor	08/31/2015 12:00:00 AM	ADDRESS	33.98338	-118.2831	Full PC for a mix used 2 story bldg. Scope of work: relocating electrical meters from inside the bldg to the outside, and upgrading the main service to 1200 A, (27) panels being rolocated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17228	17041-10000-20093	915 W WILSHIRE BLVD SUITE 2100	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.05069	-118.2599	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17229	17041-10001-23317	3680 W WILSHIRE BLVD BASEMENT	90010	10	132B193    65	5093006028	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	34.06149	-118.30603	Supplemental PC for T24 revisions. Changes include relocating lighting due to architectural changes and addition of  receptacles. Load<400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17230	16041-20002-03447	9871 N SAN FERNANDO ROAD	91331	7	201B165    79	2624020028	M1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.24947	-118.40499	7/14/17changes to an approved set of plans.  changes include relocation of unit panels.  this is plan check only.(((Revisions to approved plans.  Change to DWP fault current and equipment AIC ratings.)))  (((Plan check for power and energy.  1 story masonry block building 23279 sf  (8) units S-1 occupancy, (4) units F-1 occupancy)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17231	19041-10002-11268	4143 W DON MARIANO DR	90008	8	114B181   588	5026004008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2019 12:00:00 AM			PC Info Complete	05/10/2019 12:00:00 AM	ADDRESS	34.00642	-118.34367	Changes to approved set, scope of work includes relocation of equipment from inside to outside	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17232	14041-20000-10882	6505 N LUBAO AVE	91367	3	180B113   654	2134039019	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Expired	05/30/2016 12:00:00 AM	ADDRESS	34.18857	-118.56835	Roof mounted PV system with Optimizer, system size 4.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17233	18041-20000-47153	11935 W LAUREL HILLS ROAD	91604	2	159B169    22	2377001019	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Issued	01/04/2019 12:00:00 AM	ADDRESS	34.13598	-118.39158	PV1.  Install 14.625 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (45) modules with 5.2 and 7.6 kW rated inverters.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17234	17041-30000-13005	11130 W HESBY ST	91601	2	171B173  1106	2353011029	R4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Issued	04/20/2017 12:00:00 AM	ADDRESS	34.16167	-118.37375	Plan check for the replacement of the FACP of an existing fire alarm system for an apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17235	19041-30000-00328	11289 W PICO BLVD	90064	11	123B153   210	4260021010	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM			Corrections Issued	01/03/2019 12:00:00 AM	ADDRESS	34.03547	-118.43866	Plan check for Title 24 only. Project site is an existing fast food restaurant. Project scope is a tenant improvement. Total lighting area = 1,259 sq. ft.Note: Building application has been generated under 19014-30000-00011	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17236	19041-20002-29033	11139 N MARKLEIN AVE	91345	7	210B145   102	2664010015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM			PC Approved	11/04/2019 12:00:00 AM	ADDRESS	34.27302	-118.47098	"11-04-2019 Changes to an approved set of plan, Changes include relocate inverter disconnect and service equipment. All changes has been clouded as delta ""D"" Plan check onlyFees $0.00 due to California Senatate Bill 1222 and AB 1414"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17237	10041-20000-10643	11811 W OLYMPIC BLVD	90025	11	123B149   409	4259023015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	PIN	34.03353292	-118.45117088	INTERIOR TENANT IMPROVEMENT SCIENCE AND LIBRARY.  Applicant requested plan check for power. Title 24 energy was check in application # 10041-20000-07080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17238	14041-20000-28800	1240 S NAOMI AVE	90021	14	121-5A213  54	5130006900	PF-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.02783	-118.24431	PLAN CHECK AND PERMIT FOR 1600A DISTRIBUTION BOARD. THIS IS FOR DISTRIBUTION ONLY. NO CHANGE IN LOADS. NO CHANGE IN SERVICE SIZE. REPLACEMENT LIKE FOR LIKE. TO BE INTERCONNECTED TO AN EXISTING NEW 1600A SERVICE. THIS BOARD FEEDS 3PHASE LOADS ONLY. 3P-3W.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17239	18041-10001-19696	4150 W MARATHON ST	90029	13	141B197   347	5539021005	RD1.5-1XL	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Apartment			03/01/2019 12:00:00 AM			Reviewed by Supervisor	03/11/2019 12:00:00 AM	ADDRESS	34.08452	-118.29088	Replacing the Lost Plans.<<<PLANCHECK FOR POWER ONLY. ADDITION OF (93)  DRYER UNITS AND LAUNDRY CIRCUITS TO EXISTING APARTMENTS.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17240	16041-10000-03395	2226 N STRADELLA ROAD	90077	5	153B145   176	4377029005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.11332	-118.46236	PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.PV1 28kW AC roof mounted system with (91) SunPower SPR-x21 modules, and (2) CPS SC 14KTL inverter interconncecting through the main existing 1000-Amp service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17241	19041-20000-13741	1920 N ARGYLE AVE ev2	90068	4	150A189   137	5586006025	R3-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			04/16/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Closed	01/11/2023 12:00:00 AM	ADDRESS	34.10586	-118.32508	addition of (5) EV chargers to an exisitng service. plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17242	13041-20000-32791	5612 N VAN NUYS BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.17256	-118.44837	pc for t24 energy only. total area 2588 sq ft. existing market. new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17243	16041-30001-45773	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	02-06-2018 Changes to an approved set of plan LAX Project 5 Midfield Satellite Concourse North(MSCN) TUTL. Changes include bus way, circuit revision, lighing ajustment. all changes has been clouded as delta 2 ***********************Previouse Work Description**************************Plan check for power and Title-24.  Provide normal and emergency power to utility tunnel and baggage handling system for LAX MSC building.Building permit #16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17244	18041-10000-07455	4887 E HUNTINGTON DR NORTH	90032	14	144A233   357	5306018057	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.08678	-118.17755	PC for T24 only for replacement of indoor&outdoor existing fixtures with LED fixtures for Chase bank. Egress lighting is not part of the scope.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17245	18041-20000-41263	712 E WASHINGTON BLVD	90021	9	121-5A209 142	5131006003	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.0273	-118.25708	PV3.  Install 12.24 kW DC roof mounted grid tied PV system.  (34) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17246	19041-10000-42180	16056 W AIGLON ST	90272	11	126B121    89	4414004016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.04486	-118.538	[EPLAN] INSTALLATION OF 3 TESLA POWERWALLS ON EXISTING PV SYSTEM CONNECTED TO NEW 225A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17247	16041-10000-03910	1627 W 38TH PL	90062	8	117B193   918	5035031029	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.01655	-118.30984	PVI,  residential rooftop solar installation. total system size is 4.73kWac.(22) MODULES-SUNEDISON SE-F270     (22) MICROINVERTERS-M215 IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17248	17041-10000-03661	9151 S FALMOUTH AVE	90293	11	093B153    73	4118013915	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM			Permit Finaled	06/11/2020 12:00:00 AM	ADDRESS	33.95302	-118.43391	PC FOR T24 ENERGY ONLY FOR BLOWER ROOM. 3 NEW LIGHTSPlan Check ONLY. Permit Issued under: 17041-10001-03661	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17249	18041-20002-39703	4208 N ALLOTT AVE	91423	4	165B157   924	2373009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.14616	-118.4281	11-30-2018 Changes to an approved set, Change system from microinverter to central inverter. System size: 11.5kW DC, 9.81kW AC with 35 PV modules and 1 inverter(11.4kW).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17250	11041-20000-23835	4337 E PALMERO DR	90065	1	153A219   156	5475005029	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2011 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Expired	03/05/2014 12:00:00 AM	ADDRESS	34.11399	-118.22128	Plan check roof mounted 7.130KW Enphase Microinverter single family dwelling. Variance to install M215  prior to Test Lab approval has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17251	17041-10001-13873	1256 W 7TH ST	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Approved	05/15/2018 12:00:00 AM	ADDRESS	34.05216	-118.26774	Change to approved set by modifying the lighting plan.  All changes under delta-6 and plan check only.(((PC FOR ENERGY ONLY. T.I. CHANGE OF USE FROM COCTAIL LOUNGE TO COFFEE SHOP AT THE MAIN LOBBY. NEW CONNECTED LOAD< 400 AMP. TOTAL AREA 1406 SQ FT.B # 17016-10000-08643)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17252	14041-20000-12303	21650 W OXNARD ST SUITE 1650	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.17901	-118.60107	PLAN CHECK FOR ENERGY ONLY16th floor of commercial high rise building, new office partition walls - relocation of lighting and new occupancy sensors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17253	15041-20003-20305	7950 W SUNSET BLVD 102	90046	4	147B177  1021	5554003055	(Q)RAS4-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	ADDRESS	34.09777	-118.36322	"10-22-2015 Change to approved set of plans. Changes include adding  function area of use ""Changing Room"" in room #105 and #102 [[[[[[PC FOR POWER AND RESTAMP FOR ENERGY. CHANGE OF USE TO FITNESS STUDIO. PC FOR NEW 600A PANEL AND ASSOCIATED LOADS. PER INSPECTOR FIRST TIME OCCUPANCY.SUPPLEMENTAL PERMIT WILL BE ISSUED FOR 600A PANEL]]]]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17254	12041-10000-03041	1020 S FIGUEROA ST 2nd floor	90015	14	127-5A207  71	5138012023	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	ADDRESS	34.04442	-118.26422	Ti on the 2nd floor of an existing hotel. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17255	18041-30000-34079	245 S CONWAY AVE	90024	5	138B153    31	4359008015	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM			Reviewed by Supervisor	09/18/2018 12:00:00 AM	ADDRESS	34.07821	-118.43476	PC FOR NEW 2 STORY SINGLE FAMILY DWELLING WITH 600A NEW SERVICE 2P 120/240V.SCOPE INCLUDES NEW PANELS, CIRCUITS AND LIGHTS. B# 14010-10000-01874	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17256	18041-10000-22319	2117 W TEMPLE ST	90026	13	138A205   278	5157016032	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.10	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.07062	-118.26858	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17257	18041-10000-01308	17331 W TRAMONTO DR BLDG 9	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Issued	04/09/2018 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 9 (CAMPUS STYLE)SCOPE INCLUDES 51 DEVICES AND 2 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE. B# 15010-10000-03648 BUILDING 9 (PLAN C) 3 UNITS 4 STORY TYPE IIA APARTMENT  BUILDING  WITH ATTACHED GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17258	15041-10000-36349	2195 W 29TH ST	90018	10	123B189  1137	5052028015	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Expired	02/20/2018 12:00:00 AM	ADDRESS	34.0292	-118.31473	PV1 installation to single family home. Transformerless inverter: 3.8 kw. (12) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17259	19041-20001-37589	2636 W RANGE ROAD	90065	14	159A219   243	5684036023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	PIN	34.12975918	-118.2236942	11-01-2019 Changes to an approved set of plan, changes include reduction of number of PV Modules to (24) PM Modules, layout of PV Modules on roof. All Changes has been clouded. Revised system size: 7.56 kW DC.$0 plan check and permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17260	14041-20000-27078	1570 W FAIR PARK AVE	90041	14	160-5A227 269	5689026007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.13374	-118.20042	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17261	19041-20000-49871	2118 N KEW DR	90046	4	151-5A173 211	5567011023	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Expired	02/23/2021 12:00:00 AM	ADDRESS	34.10924	-118.37604	PV1. INSTALL 7.56 KW DC PV SYSTEM WITH (24) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17262	15041-20001-42334	423 N ARBRAMAR AVE	90272	11	126B125   601	4413008009	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.04094	-118.53666	02/04/2016 Changes to an approved set of plans. Inverter count has been reduced to (1) inverter, module count has been reduced to (32) modules, and there is no longer a solar load center. New system size is now 7.7 kWac. All changes have been clouded and marked as Delta 1.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 15.4 kWac and consists of (2) inverters, (48) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17263	13041-20000-09871	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	04/19/2013 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.03396	-118.24117	Install new transformer to supply renamed panel RMS and new panel RIDF.  If panel RMS is new, additional fees are required to be paid.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17264	15041-10000-18581	614 E TERMINAL WAY chassis-shop	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.74201	-118.26431	New fire warning system for Chassis Shop Building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17265	10041-10000-10872	216 E 31ST ST	90011	9	118-5A205  77	5120001014	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM			Verifications in Progress	08/19/2010 12:00:00 AM	ADDRESS	34.0202	-118.2696	New PV system for a church.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17266	12041-20000-14143	1334 S CENTRAL AVE	90021	14	121-5A213   5	5130008042	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.02855	-118.24651	T24 lighting plan check for remodeled restrooms and locker rooms in coca cola plant 1st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17267	13041-20000-11912	5055 W WILSHIRE BLVD 500	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.06235	-118.34036	energy plan check # 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17268	17041-20001-28095	22935 W OXNARD ST	91367	3	177B097   461	2039016013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.17929	-118.62665	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (48) modules, (48) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17269	14041-20000-16594	445 S FIGUEROA ST Floor 30	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	TI to commerical office space in (E) commercial highrise building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17270	19041-10000-05587	2700 N VERMONT AVE	90027	4	153B193   686	5593002913	OS-1XL	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Issued	01/13/2020 12:00:00 AM	ADDRESS	34.11803	-118.29221	"Install new lights in the Verizon ""Head End Equipment Room"". T-24 Energy Only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17271	19041-20000-16713	24641 W CANYONWOOD DR	91307	12	183B085   109	2031010036	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.19828	-118.66152	Plan check for Battery back up system installed in to existing PV system, Battery system size: 13.5kWh .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17272	18041-10000-35579	5233 W MELROSE AVE	90038	13	141B189   330	5535002024	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Issued	09/18/2018 12:00:00 AM	ADDRESS	34.08364	-118.31479	Plan check for PV2 7.6kw AC roofmounted system with (1) 7.6KW Solaredge inverter and (34) modules interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17273	18041-10000-29461	10867 W SANTA MONICA BLVD	90025	5	129B153   486	4324028044	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.04989	-118.43763	PC FOR POWER ONLY,  SCOPE OF WORK INCLUDES A NEW 800 AMP SERVICE AND THE INSTALLATION OF EV CHARGES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17274	12041-20000-22416	5436 N PENFIELD AVE	91364	3	171B113    14	2164003022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.16918	-118.56831	Photovoltaic system for an existing single family house using Enphase M215 micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17275	13041-20000-16106	7300 W HOLLYWOOD BLVD	90046	4	147B181   182	5550016024	[Q]R5-1	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.10144	-118.34913	New panels, lighting, loads, in an existing Temple/School.  Load is greater than 400 amps, Place of Assembly.  Full Plan check required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17276	16041-20000-28545	933 N LA BREA AVE 4th Floor	90038	5	144B181   679	5531016022	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.08811	-118.34432	Plan check for energy only. TI to commercial space on 4th floor of building. New lighting (incl. emergency) and receptacles. 4,048sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17277	15041-10000-11014	11050 W MAGNOLIA BLVD	91601	2	171B173   611	2353005001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM			PC Approved	04/14/2015 12:00:00 AM	ADDRESS	34.16478	-118.3723	Energy plan check for change  of  use  from  theater  to a restarant . NEWLY CONNECTED LOAD  <400 AMPS. 4970 SQFT. Reference plan check  #: 14041-10000-25405 for original T24 with emergency light.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17278	15041-10000-40647	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	07/12/2017 12:00:00 AM		Issued	07/12/2017 12:00:00 AM	PIN	33.92817449	-118.43220714	UPGRADE SCREWPUMPS FOR WATER TREATMENT.  PLAN CHECK FOR POWER ONLY.PAYMENT WITH IDO #ID1670X0207	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17279	16041-20000-07010	7175 W WILLOUGHBY AVE	90046	5	144B181   752	5531016007	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.0872	-118.34594	(N) fire alarm system for (E) unsprinklered single-story office building with central station monitoring.  (1) FACP with (19) initiation/notification devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17280	16041-20000-23106	706 W MANCHESTER AVE Bldg B	90044	9	097-5A207 307	6042002031	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Closed	03/01/2017 12:00:00 AM	ADDRESS	33.95986	-118.26272	Plan check for Title 24 only in existing class room Building B. Total area: 972 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17281	17041-20000-31656	6461 N PEACH AVE	91406	6	180B145   590	2234015005	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.18838	-118.46781	PV1.  Install 13.44 kW roof mounted grid tied PV system.  Microinverter system with (40) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17282	14041-10001-30005	16490 W EL HITO PL	90272	11	132B121   120	4420017020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2014 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.05962	-118.54179	EXPERDITE PER CUSTOMER REQUEST((PV 1 ROOFMONTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. 2 INVERTERS AND 50 MODULES AND SYSTEM SIZE 12.75KW.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17283	15041-20000-06637	11643 N GLENOAKS BLVD	91331	7	213B157   324	2524022006	C2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.28129	-118.42005	Title 24 plan check only.  Total area = 4,684 sq. ft.T.I. to existing woman's shelter.  New lights and recepticles.  No medical space included in scope of work.  New connected load less than 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17284	16041-10002-16707	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Issued	07/11/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC FOR POWER. EXTENSION OF 7 MEDIUM VOLTAGE   (34.5KV) CIRCUITS CLOUDED UNDER DELTA 9G, 1C, 2G, 1B, 1D SPLICING TO APPROVED LINES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17285	11041-10000-12512	13213 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Info Complete	08/31/2011 12:00:00 AM	ADDRESS	34.31094	-118.42882	CHANGE OF USE TO A RESTAURANT. PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17286	13041-10000-34132	1823 E 45TH ST BLDG C	90058	9	112-5A215  43	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.00291	-118.24056	PLAN CHECK FOR EMERGENCY LIGHTING AND EXIT SIGNS ONLY PER INSPECTORS REQUEST. 3 OF 5 BUILDINGS. BUILDING C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17287	16041-10000-01435	4348 W SUNSET BLVD	90029	13	147A201   263	5429006002	C2-1D	Central	Hollywood	Los Feliz		1913.02	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.09528	-118.28388	Energy plan check for a restaurant (Mc Donald) T.I . Scope include new lighting and receptacle. Total area is 2794-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17288	18041-20002-08945	539 S MAPLETON DR	90024	5	138B157    57	4359013038	RE40-1	West Los Angeles	Westwood	Bel Air - Beverly Crest, Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.07466	-118.42924	05-01-2018 Changes to an approved set of plan. Changes include reconfigure module layout on roof. Changes has been clouded as delta B.1. Plan check only FEE $0.00 BY STATE SENATE BILL NO. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17289	14041-20000-01488	10410 N JELLICO AVE	91344	12	207B129  1035	2733012035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.25996	-118.51853	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17290	10041-10000-11343	3804 S BROADWAY PL	90037	9	117A203   307	5122040017	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM			PC Info Complete	06/15/2010 12:00:00 AM	ADDRESS	34.01279	-118.27611	RENOVATION OF KITCHEN & MEN'S RESTROOM. COMPLY W/ DEPT ORDER DATED 05/27/05. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((  Title 24 and emmergency lighting  ))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17291	12041-10000-10005	1151 W 6TH ST	90017	1	132A207   248	5152001001	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.0548	-118.26346	remodeling of existing offices-full plan chk	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17292	11041-10000-15676	2030 S BENTLEY AVE 1-5	90025	5	126B153   427	4323023***	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			07/26/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.04282	-118.43871	Original fire alarm panel burned out.  Applicant is replacing the panel one for one.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17293	13041-20001-22821	6868 W GRENOBLE ST PV-1	91042	7	207B201   215	2553011020	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM			PC Approved	08/24/2013 12:00:00 AM	ADDRESS	34.26146	-118.28103	PV-1. Power optimizers. 3kW Inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17294	10041-10000-03935	13061 S KIYOT WAY	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/22/2010 12:00:00 AM	PIN	33.97159161	-118.42340103	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17295	18041-10000-22143	14626 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.22128	-118.45073	$0.00 FINAL FEE DUE TO SENATE BILL 1222 & LB1414PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM FOR GROCERY STORE - SYSTEM SIZE = 86.6KVA SYSTEM CONSISTING OF 2 CENTRAL INVERTERS (SE10KUS AND SE66.6K) WITH 260 MODULES AND P370 POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17296	19041-20000-16367	11300 W OLYMPIC BLVD	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.03792	-118.44134	T24 PLAN CHECK ONLY FOR LIGHTS ONLY. EXISTING BRANCH CIRCUITS ONLY. TOTAL SQUARE FOOTAGE = 1775SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17297	18041-10000-27204	17575 W PACIFIC COAST HWY	90272	11	126B117   563	4416012030	C2-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.04	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.04033	-118.56055	NEW FIRE ALARM SYSTEM	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17298	18041-10000-12261	19191 S VERMONT AVE 470	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 3583 SQFT. SUITE 470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17299	11041-10000-16963	9454 N GIERSON AVE	91311	12	198B101    50	2727020020	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2011 12:00:00 AM			Corrections Issued	08/11/2011 12:00:00 AM	ADDRESS	34.24241	-118.61131	New 12.88 KW roof mounted PV system.  Applicant used the standard plan for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17300	15041-20000-07426	13215 W OTTOMAN ST	91331	6	195B157   158	2627014023	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Issued	03/13/2015 12:00:00 AM	ADDRESS	34.23396	-118.42091	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (27) modules and (1) inverter. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17301	18041-10000-47255	1323 N ISLAND AVE	90744	15	033B205    87	7420004022	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	33.78958	-118.26698	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 8 MODULES (Q-CELL QPEAK 315) , 8 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 2.52KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17302	15041-20000-43906	7929 S FORDHAM ROAD	90045	11	099B157    80	4113021004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	33.96654	-118.41889	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (21) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17303	15041-20000-39390	21723 W VANOWEN ST	91303	3	183B105   926	2138006034	P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.19391	-118.60238	INTERIOR T. I. & CHG OF USE OF 53'X104'(5421 S.F)  FROM RETAIL TO DANCE STUDIO.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17304	18041-20001-12316	11408 W ALBATA ST	90049	11	135B145   685	4365017002	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM			PC Approved	10/25/2018 12:00:00 AM	ADDRESS	34.06362	-118.4613	10-25-2018 Changes to an approved set of plan. Changes include addtion of sub panel(Under separate permit) and J-box for future Battery System. All Changes has been clouded. Plan check only, permit covered under Master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17305	13041-10000-10854	6840 W HOLLYWOOD BLVD	90028	13	147B181   191	5548006006	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/26/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.10137	-118.34026	Plan check power for new roof top equipment and replace existing 400A and 800A panels to withstand new available fault current.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17306	11041-10000-18597	5711 N VAN NUYS BLVD	91411	2	174B149   556	2244028022	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	PIN	34.17423449	-118.44919365	Per applicant request for plan check.  Plan check is for energy and power. T.I.  New dealership in an existing building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17307	16041-10000-20648	1521 E 55TH ST	90011	9	108B213   229	5105004021	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	33.99311	-118.2469	PV1 INSTALL NEW 5.30 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17308	15041-10000-39805	30 N LATIMER ROAD	90402	11	126B133     2	4409013013	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.04484	-118.51179	FULL PC TO A NEW HOME WITH THREE STRUCTURES, CONNECTED TO AN 800 AMP SERVICE AND SWITHGEAR. TOTAL SQ. FT. 14,115.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17309	18041-20001-35809	12762 W VANOWEN ST 7	91605	2	180B161    67	2325004027	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.03	Electrical	Electrical	Apartment			10/12/2018 12:00:00 AM			PC Approved	10/16/2018 12:00:00 AM	ADDRESS	34.1938	-118.41158	Plan check for additonal of an unit of existing multi-family building per inspector request. Plan check only Permit pulled under B#17016-2001-23994	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17310	16041-20000-04044	3665 S HUGHES AVE	90034	5	120B165   600	4313008036	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.02575	-118.4009	$0 permit fee is due to State Senate Bill SB 1222PV2. ROOFMOUNTED SOLAR INSTALLATION. CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 55 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17311	13041-10000-22477	921 S CROCKER ST	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.03582	-118.24984	2 STORY ADDITION W/MEZZANINE  RENOVATION (DEMO+ADDITION) OF EXISTING WAREHOUSE,  CONVERT PORTION OF (E) BUILDING TO PARKING GARAGEEXISTING BUILDING SERVICE UPGRADE CORE AND SHELL ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17312	14041-20000-20563	11351 N DRONFIELD AVE	91331	7	210B165     6	2532009009	A2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM			PC Info Complete	10/17/2014 12:00:00 AM	ADDRESS	34.27673	-118.4036	(($0 permit fee due to senate bill 1222 from 2012))New building roof mounted PV system with system 57.25KW for new school.Note: The other PV system (68.75KW) is carport roof mounted system is under 14041-20000-20567.  Both PV systems are on the same plans.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17313	18041-20001-26632	5751 W VALLEY OAK DR	90068	4	151-5A191 155	5587013038	RE9-1D	Central	Hollywood	Hollywood United	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.10984	-118.31483	09-26-2018 Changes to an permitted set of plans, changes include addition of 6 PV Modules and increase one to PV inverter to 7.6KW, addtion of PV load center, update main panel to 400A existing. All changes has been clouded. Update PV System size to 15.275 KW.Fee $0.00 due California Senate Bill 1222 and Assembly Bill 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17314	12041-10000-14811	111 E UNIVERSAL HOLLYWOOD DR 18TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING EXISTING FLOOR HAVING OFFICES ON 18TH FLFULL PLAN CHK AS THE NEW LOAD IS GREATER THAN 400AMPERES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17315	19041-10000-47500	5311 W SANTA MONICA BLVD	90029	13	144B193   629	5537008020	C2-1D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.09093	-118.30505	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17316	19041-20000-36195	6956 N VANSCOY AVE	91605	2	183B161   569	2324030044	R1-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Issued	09/11/2019 12:00:00 AM	ADDRESS	34.19737	-118.4061	PV1. INSTALL 5.8 KW DC / 6 KW AC SOLAR SYSTEM WITH (20) MODULES AND AND (1) INVERTER (SOLIS-1P6K-4G)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17317	19041-10001-23081	340 N PATTON ST	90026	1	135A209    13	5160009002	CW	Central	Westlake	Echo Park	YES	2080.00	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM			PC Approved	12/03/2019 12:00:00 AM	ADDRESS	34.06618	-118.25846	Changes to an approved set of plans. All changes are under delta 2. Revising floor plans, and riser diagram.Note: Permit is paid under master application. PC only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17318	16041-10000-16771	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.07196	-118.24719	TITLE 24. AREA = 38,922SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17319	12041-20000-11674	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin # 170 T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17320	17041-10000-26082	21012 W LASSEN ST	91311	12	201B109   113	2746003015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Issued	08/01/2017 12:00:00 AM	ADDRESS	34.2498	-118.59127	TITLE 24 PLAN CHECK FOR REMOVAL OF (8) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA = 22600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17321	16041-10000-30467	20417 W NORDHOFF ST	91311	12	195B109    62	2781001035	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.232	-118.57818	Title 24 plan check only.  Total area = 43,297 sq. ft.Remove HID fixtures and replace with new LED fixtures on building exterior to illuminate outdoor parking lot and alley.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17322	15041-20000-23260	444 S FLOWER ST 47th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is an existing commercial high-rise building (bathroom). Project scope is a tenant improvement. Total lighting area = 535 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17323	13041-10000-26137	24316 W BURBANK BLVD	91367	3	174B089   612	2047017009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.16975	-118.65499	PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING TO MAIN PANEL IN A SINGLE-STORY HOUSE ON NON-STANDARD PLAN. NEW 100A PV LOAD CENTER WILL BE INSTALLED. SYSTEM SIZE 8.25KW DC. 2 TOTAL STRINGS, 1 STRING OF 16 MODULES. (33) MODULES: RENESOLA SOLAR MODULES - JC250M-24/BB(2) INVERTER: SOLAR EDGE  - SE3800A-US, SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17324	15041-10001-26872	745 S COLUMBIA AVE	90017	1	130-5A205 193	5142021002	R3-1	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM			PC Approved	09/22/2015 12:00:00 AM	ADDRESS	34.05167	-118.26946	EXPECTED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, ADDING NEW 6.89 KW DC SOLAR ARRAY TO AN EXISTING SOLAR ARRAY SYSTEM ON A SINGLE FAMILY HOME.(26) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17325	18041-10001-48219	6262 N VAN NUYS BLVD	91401	6	178-5A151 200	2240003907	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.18408	-118.44846	SUPPLEMENTAL FOR FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED 7.6KVA SYSTEM CONNECTED WITH AN EXISTNG 4.0KVA SYSTEM TO AN EXISTING 400A 120/240 PANEL. SYSTEM CONSIST OF 1 CENTRAL INVERTER(SE7600H-US) WITH 27 MODULES USING P320 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17326	19041-20000-48894	10601 N OVERMAN AVE	91311	12	207B109   514	2707018025	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	02/11/2020 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.26248	-118.57811	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 7.56 KW DC/7.6 KW AC. SCOPE OF WORK CONSISTS OF (27) MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17327	13041-20000-32046	21300 W VICTORY BLVD #500	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.18813	-118.59618	Office remodel of and existing high-rise office.  Change to lights using existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17328	10041-10003-22525	613 S GAYLEY AVE	90024	5	135B149   241	4363006020	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.06762	-118.44862	Revision to approved plans.  Addition of one lighting fixture and gfci receptacle for added 4th floor bathroom.  Changes under delta-8.  Approved set of plans for PCIS #10041-10002-22525 provided.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17329	15041-10000-21023	4245 N LANKERSHIM BLVD	91602	2	165B177   832	2423022045	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.14719	-118.3642	PC FOR ENERGY. REMODELING OF BMW DEALERSHIP. TOTAL AREA 20202 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17330	15041-20000-11499	1515 W 190TH ST Suite 500	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	33.85852	-118.30531	TItle 24 plan check only.  Total area = 5,578 sq. ft.T.I. to existing commercial office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17331	10041-20001-16671	12740 W ARROYO ST	91342	7	219B161   249	2525027014	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	12/13/2010 12:00:00 AM	ADDRESS	34.29585	-118.41002	PLAN CHECK FOR DELTA 2.  INSTALL NEW TRANSFORMERS AND DISCONNECTS SUPPLYING FOR SWAMP COOLERS, COMPRESSOR, AND AIR DRYER TO REDUCE AVAILABLE FAULT CURRENT. REVISE LOAD CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17332	13041-10000-32630	5106 N MATILIJA AVE	91423	4	171B153   595	2269003003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.16343	-118.43332	PV1. ROOF MOUNTED PHOTOVOLTAIC SYSTEM. TRANSFORMERLESS UNGROUNDED SYSTEM. SYSTEM SIZE:4KW  USING (16) RENESOLA SOLAR MODULES JC 250M (16) POWER OPTOMIZERSAND (1) SOLAREDGE SE3800. PV WIRE USING LA TEST LAB APPROVED INDUSTRIAL WIRE PVX1019	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17333	11041-10000-12747	380 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/27/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of  5 elevator unit in TBIT at LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17334	15041-10001-02013	21200 S BRIGHTON AVE	90501	15	051B193   340	7349021007	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM			Reviewed by Supervisor	02/03/2015 12:00:00 AM	ADDRESS	33.8363	-118.30043	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 3.57 ROOFMOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.14 MODULES AND 14 MICROINVERTERS.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17335	13041-20000-25491	17031 W BURTON ST	91406	6	192B133   299	2204033010	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.22023	-118.50376	PV1 SINGLE FAMILY DWELLING. THIS INSTALLATION IS AN ADDITION. NEW INSTALLATION IS 3.8 KW AC USING 15 MODULES WITH POWER OPTIMIZERS. TRANSFORMERLESS INVERTER. PC FOR NEW INSTALLATION ONLY AND PV LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17336	18041-10000-43426	2755 N FRUITDALE ST	90039	13	150A209    55	5437033031	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.10677	-118.2544	PLAN CHECK FOR POWER AND ENERGY FOR - CHANGE USE FROM WAREHOUSE/OFFICE/TOW OFFICE-TO-WAREHOUSE & OFFICE WITH 2-STORY WAREHOUSE/OFFICE/GARAGE. TOTAL AFFECTED AREA = 4400 SQ. FT. TOTAL CONNECTED LOAD >400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17337	11041-10000-13521	1023-1033 S DOREEN PL Bldg #3-1	90291	11	111B145   819	4243003033	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	33.99991	-118.46013	New 2 story 9 unit apartment building.  Full plan check.Note to plan checker:  At the time the application was generated, plans were not available.  Fees are based on what the engineer had filled out on the plan check application.  Verify fees and quantity of units during plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17338	13041-10002-29570	9714 N ORCAS AVE	91040	7	201B173   350	2542023010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.24575	-118.36701	((((plan check only. changes to site plan. changes clouded delta B. plan check for delta B only))))PV1.  Install 12.25 kW DC roof-mounted solar array, interconnect with main service panel.  Multiple inverters.  50 modules: Yingli Yl245p-29b.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17339	19041-20000-21430	1244 S LONGWOOD AVE	90019	10	129B181   289	5083019025	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.05199	-118.34056	Plan check for a PV1 roof-mounted PV system. System size is 3.74 kWdc/3.7 kWac-CEC and consists of (12) modules, (12) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17340	14041-20000-31201	19930 W ACRE ST	91324	12	195B113   341	2782029014	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.2299	-118.56794	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3KW INTERCONNECTED WITH MSP.(20) SUNTECH POWER 250W MODULES(20) ENPHASE M250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17341	16041-20000-38670	642 N STANLEY AVE	90036	5	141B177   701	5526015023	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.08309	-118.35622	pv1install roof mounted pv system sized 7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17342	19041-10000-14575	400 S HOPE ST 2ND FLOOR	90071	14	130-5A211 189	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Issued	04/22/2019 12:00:00 AM	ADDRESS	34.05199	-118.25366	Energy plan check for an office T.I located on the 2nd floor of a high rise building. Scope includes new lighting and equipment with a total area of 1883-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17343	18041-10000-29936	970 N MONUMENT ST SUITE 119	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Closed	07/08/2021 12:00:00 AM	ADDRESS	34.04646	-118.52393	NEW RESTAURANT. FIRST TIME TENANT. PLAN CHECK FOR POWER NAD ENERGY.BLDG PERMIT#: 18016-10000-21227	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17344	18041-20000-00323	9901 S LA CIENEGA BLVD Basement	90045	11	090B173    36	4128017045	C2-2, LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	33.94626	-118.37022	Plan check for Title 24 only. Project site is the basement of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,102 sq. ft.Note: Building application has been generated under 17016-10000-23343	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17345	15041-10001-38840	9008 N LEMONA AVE	91343	6	195B149   105	2651017004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.23382	-118.45893	PC needed per inspector, Permit pulled online under 15041-90000-38840.***Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17346	12041-20000-12230	10250 W SANTA MONICA BLVD #187	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM			PC Approved	05/29/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	energy plan check space # 187	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17347	18041-20001-38463	5367 N WINNETKA AVE	91364	3	171B113    69	2166006007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.16778	-118.5711	Revision to approved set.  Change of wiring and interconnection details.  Approval for clouded changes only. (((pv1extend existing roof mounted pv system with 7.6KW AC interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17348	19041-20002-06839	9333 S LINCOLN BLVD PV1	90045	11	096B161   838	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	33.95576	-118.41559	System redesign.  Reduction in number of modules, type and quantity of inverters, elimination of transformer.  New system size is 91.98 kW DC / 82.77 kW AC CEC with (252) modules and (2) 43.2 kW rated inverters.  System 3 of 3.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17349	14041-10000-21498	11120 W HUSTON ST 1-34	91601	2	168B173   208	2353020031	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.15954	-118.37245	Installation of fire alarm system for new 3 story 34 unit apartment building.  Total devices = 105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17350	14041-10000-05380	1999 W ADAMS BLVD	90018	8	123B193   477	5058015005	[T][Q]C2-2D	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.03285	-118.30872	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. ELECTRICAL UPGRADES TO THE GOLDEN STATE MUTUAL LIFE INSURANCE BUILDING. BUILDING PERMIT # 14016-10000-03610   TENANT IMPROVEMENTS, WILL NOT CHANGE THE BUILDING OCCUPANCY OR OCCUPANT LOAD AND WILL NOT ALTER THE HISTORIC CHARACTER OF THE BUILDING.  see comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17351	19041-20000-38813	5757 W WILSHIRE BLVD 372	90036	4	135B177   594	5508015009	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 energy only in existing space, Tenant Imporvement to Suite #372. Total area: 2000 sq ft. B#19016-10000-26684	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17352	15041-10000-11995	100 WORLD WAY TERM-2	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	AT LAX, INSTALLATION OF ILLUMINATED SIGN NUMERALS IDENTFYING THE INDIVIDUAL TERMINAL .EACH SIGN NUMERAL WILL BE SUPPLIED FROM A 20-A BRANCH CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17353	16041-20000-21750	11407 N RUGGIERO AVE	91342	7	213B173   399	2529020007	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.27717	-118.36697	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17354	13041-10000-12777	5528 N VOLETTA PL	91607	5	174B161   515	2346028031	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.17121	-118.41091	PV1 14.7KW ROOFMOUNT. nonstandard plan.  2STORY. (-) GROUNDED. FRONIUS #IG PLUS V (7.5 and 3.8). 60 MODULES TSM-245PC05	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17355	18041-20001-04740	11335 W DONA DOROTEA DR	91604	2	156B169    99	2381007029	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Issued	08/09/2018 12:00:00 AM	ADDRESS	34.12722	-118.38066	08-09-2018 Changes to an permitted set of plan, changes include addition of disconnect for Tesla PowerWall. All Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17356	18041-20001-40068	245 N TOYOPA DR	90272	11	123B129   686	4411024027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.03161	-118.52	expeditepv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17357	10041-10000-04961	6327 W HOLLYWOOD BLVD	90028	13	148-5A187 151	5546004012	C4-2D-SN	Central	Hollywood	Hollywood United		1902.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	34.10178	-118.32776	FIRE ALARM SYSTEM FOR RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17358	18041-10002-24837	4141 W SANTA MONICA BLVD	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	"DELTA ""1"" Changes ONLY to T-24 approved plans in Basement, 1st Floor (Restaurant) and Pool Deck area. Affected area: 10,627 SFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17359	15041-20000-14265	20218 W RUNNYMEDE ST	91306	3	186B113   471	2114011031	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.2058	-118.57372	Plan check for PV roof mounted system 6.0kWac with 29 modules (Kyocera KU2606XPA) and  1 inverter(6.0kW) Standard Plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17360	19041-20000-26627	5711 W CENTURY BLVD	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Info Complete	10/15/2019 12:00:00 AM	ADDRESS	33.94573	-118.38128	TI to (E) hotel common areas.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17361	14041-10000-16719	11100 W SANTA MONICA BLVD SUITE 1150	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLAN CHECK FOR ENERGY ONLY FOR EXISTING HIGHRISE TI. SCOPE OF WORK IS ON THE SUITE 1150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17362	18041-10000-34040	12105 N ARROYO VISTA WAY	91326	12	219B109    13	2701001047	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.29288	-118.58648	PC FOR POWER AND ENERGY FOR A DETACHED CABANA/PATIO. SCOPE INCLUDES INSTALLATION OF A 70A SUBPANEL, NEW RECEPTACLES, AND NEW LIGHTING. NOTE: ONE SET OF PLANS WAS SUBMITTED FOR TWO APPLICATIONS(2 OF 2).  B#16010-20000-05709	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17363	19041-20000-48299	2005 S FAIRBURN AVE	90025	5	129B157   333	4317005026	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.05176	-118.42626	PV1. INSTALL 4.95 KW DC PV SYSTEM WITH (15) MODULES/OPTIMIZERS AND (1) INVERTER (SE5000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17364	12041-10000-12716	4290 N PERLITA AVE	90039	13	159B205   767	5594010031	(T)(Q)RD2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.13115	-118.26793	Plan check for new roof mounted 5.1KW photovoltaic system for an existing single family dwelling with Enphase M215 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17365	14041-20000-32673	16801 W MOONCREST DR	91436	5	165B133   338	2291010010	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.14766	-118.49899	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating the main to 175A.System size: 8.64kW. Ungrounded system.36 EnPhase M250 microinverters with 36 275W pv modules across 3 strings (12+12+12).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17366	13041-10000-05334	11705 W PICO BLVD	90064	11	123B149   637	4260029034	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	34.03164	-118.44601	TI OF EXISTING OFFICE SPACE. PC FOR T24 ONLY, PERMIT ALREADY ISSUED. NO PERMIT TO BE ISSUED FOR THIS APPLICATION #. TOTAL AREA 2100 SQ FT. WITH FULL KITCHEN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17367	10041-10000-18522	2049 S CENTURY PARK EAST 2nd flr	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM			No Progress	09/17/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI 2nd floor, T 24 only about 1100 sq ft, B of A plus emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17368	14041-20000-01917	2320 N CLAREMONT AVE	90027	4	148-5A203  75	5433017033	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.10255	-118.27388	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 2.75KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17369	15041-10000-11222	840 N ECHO PARK AVE 1-50	90026	1	138A209   100	5404019024	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM			PC Approved	04/15/2015 12:00:00 AM	ADDRESS	34.07326	-118.25938	T24 FOR OUTDOOR LIGHTS FOR EXISTING PARKING STRUCTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17370	15041-10000-07082	1179 W 16TH ST	90731	15	012B193   515	7458027028	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	33.72963	-118.30297	PV1, INSTALL 6.6 KW AC ROOF -MOUNTED SOLAR ARRAY ON A SINGEL FAMILY HOME. INTERCONNECT WITH MAIN SERVICE PANEL.(29) MODULES: KYOCERA KU2606XPA(2) INVERTERS: ABB PV1-3.0-OUTD-S-US-Z-A & PV1-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17371	18041-20000-39964	5104 E RANGE VIEW AVE	90042	14	156A225    57	5479027017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.12352	-118.20382	Plan check for PV roof mounted and energy storage system, PV system size: 7.6kW with 15 PV Modules and 1 inverter, 1 LG battery	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17372	16041-10001-10777	11109 N SEPULVEDA BLVD Suite 102	91345	7	210B145   124	2664007011	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.27256	-118.46785	Changes to approved set.  Service change from underground to overhead.  Available fault current remains the same.  Changes clouded with delta 9.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17373	13041-20000-33708	16304 S VERMONT AVE	90247	15	069B197   333	6120018084	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Apartment			12/04/2013 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.88328	-118.29117	new 79 units apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17374	16041-20000-04852	20335 W VENTURA BLVD #235	91367	3	174B113   533	2166033041	(Q)C4-1LD, (Q)P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	PIN	34.1694254	-118.57651453	Plan check for Change of use from office to Dental Office 4 treatment rooms, 1 laboratory and 2 offices. Total area: 1,791 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17375	18041-20000-34275	8921 N FULLBRIGHT AVE	91311	12	195B113    71	2781001050	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	34.23274	-118.57773	Plan check for a PV2 roof-mounted PV system. System size is 30.6 kWdc/30 kWac and consists of (3) inverters, (102) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17376	18041-20000-47800	15131 W WEDDINGTON ST pv1	91411	4	172-5A147 137	2250004025	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.16744	-118.46294	pv1install roof mounted pv system sized 4.1KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17377	14041-10000-11930	700 E VERNON AVE	90011	9	112-5A207  72	5108002034	RD2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.00368	-118.26341	PV1 3.06KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(12)modules: {Trina {TSM-250PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17378	12041-20000-21248	6049 N VINELAND AVE	91606	2	177B173   890	2337001033	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.18079	-118.37049	T-24 lighting plan check for a new 2 story building.  The service is 400 amperes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17379	14041-20001-19404	1322 S BRINKLEY AVE	90049	11	129B137   272	4407011014	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM			PC Approved	07/25/2014 12:00:00 AM	ADDRESS	34.05128	-118.49655	Modification to approved set.  Change of module locations and # of modules per string.  Total number of modules unchanged.  $0 plan check fee is due to Senate Bill SB-1222. (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.84KW INTERCONNECTED WITH MAIN SERVICE PANEL.(41) ENPHASE MICROINVERTERS M250(41) SOLAR WORLD SW280 MODULES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17380	10041-10000-13621	4965 E HUNTINGTON DR NORTH	90032	14	144A233   284	5306014053	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	09/12/2011 12:00:00 AM	ADDRESS	34.08771	-118.17537	upgrade electrical service from 400 oh to 600 amps under ground .Intercept to old service about 4 feet of  stowand 67% deratedand remove and coverold meter and use the panel as branch panel.transformer and fuses are provided.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17381	13041-20000-14060	100 N LA CIENEGA BLVD #233	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	08/28/2013 12:00:00 AM	ADDRESS	34.07466	-118.37629	Change to lighting at an existing retail space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17382	17041-10000-06881	10479 W PICO BLVD	90064	5	129B161   456	4315005027	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.04553	-118.41889	PC for outdoor title 24 only. Removing HID fixutres with new LED fixutres. Area: 14400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17383	18041-10001-41153	13627 W SUNSET BLVD	90272	11	129B133    62	4425013016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.0526	-118.50356	SUPPLEMENTAL FOR FEE EXPEDITEPLAN CHECK FOR A ROOF MOUNTED PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 45 MODULES USING POWER OPTIMIZERS(P320)EXISTING PV SYSTEM ON ROOF. (INFORMATION UNKNOWN)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17384	14041-20001-08550	4802 N VANALDEN AVE	91356	3	168B117   255	2176034015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.15756	-118.55294	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17385	11041-10000-12769	400 W WORLD WAY WEST TERMINAL-# 4	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/10/2011 12:00:00 AM	PIN	33.94386803	-118.39979044	REPLACEMENT OF 9 ELEVATORS IN TERMINAL 4 AT LAXPLAN CHK IS REQUESTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17386	14041-10005-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	"01/26/17Changes to an approve set of plans. All changes are made under delta 24. Changeson distribution board ""DA"" and ""DB"" only (ref. sheet on core and shell: 3.E.04.07)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17387	17041-30001-15488	2134 W SUNSET BLVD A	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.07723	-118.26485	11-28-2017 Changes to an approved set of plan. Changes include re-feed each panel with individual meter total of 3 meters. Changes has been clouded. *****************************Previous Work Description*********************************Plan check for power and energy. Project site is a suite within an existing commercial building. Project scope is a first time tenant. Total lighting area = 1,845 sq. ft.Note: Building application has been generated under 17016-30000-07986	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17388	18041-10000-40499	5648 N HAZELTINE AVE	91401	2	174B153  1362	2246032031	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.17331	-118.43972	PV1, ROOF MOUNTED SOLAR SYSTEM TO A CONDO USING CENTRAL INVERTERS AND MODULES WITH OPTIMIZERS. (1) 3KW INVERTER AND (9) MODULE. TOTAL SYSTEM SIZE 2.93KWDC/ 3KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17389	18041-20000-37533	10853 N CARTWRIGHT DR	91311	12	210B113   255	2708029014	(T)(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.26823	-118.56651	pv1install roof mopunted pv system sized 5.7KW AC interconnected wtih msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17390	16041-10000-12484	1313 W SUNSET BLVD 1-27	90026	1	138A211   226	5406014040	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley		YES	1977.00	Electrical	Electrical	Apartment			04/11/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.07175	-118.25041	New fa system for a 27 apartment building. 67 fa devices. 1 fa panel, 2 control panel and 2 communication panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17391	17041-10000-27825	2511 S VERMONT AVE	90007	8	123B197   781	5054027027	[Q]C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.03336	-118.29178	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY. TOTAL SQUARE FT 14800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17392	19041-20000-11030	340 N MADISON AVE	90004	13	138B197   117	5501002033	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	11/10/2020 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	ADDRESS	34.07748	-118.28901	Plan check for Title 24 Energy only in existing space tenant improvement. Total area: 15882 sq ft. B#19016-10000-02368	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17393	17041-10002-34329	2911 W BEVERLY BLVD	90057	13	138A201   301	5156019030	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM			Corrections Issued	12/27/2017 12:00:00 AM	ADDRESS	34.07133	-118.28058	VOID- Plan check done under 17041-10003-34329Changes to an approved set of plans, Note changes under the clouded areas. ________________________________________________________Install new rooftop solar system on a multi tenant commercial building, 32.86 kW DC system.  (124) modules with (124) enphase microinvertersZEO PERMIT FEE IS DUE TO SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17394	18041-20001-17543	6400 N LAUREL CANYON BLVD Suite 640	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.18693	-118.3963	06-08-2018 Changes to an approved set of plan, changes include reconfigured office layout. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17395	14041-20000-01712	442 S VIRGIL AVE	90004	13	135A201   230	5077001039	(Q)CR-2	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			01/21/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	PIN	34.06557536	-118.28662708	New 5-story apartment over 2-level parking garage with 74 units locate in Methane Zone.  New 2000A service, panels, branch circuits, and lighting.  Plan check for power and energy.Note: Variance to separate fire plans submitted on 6/30/14.  Methane Certificate of Compliance and Conduit Seal Detail attached with the plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17396	14041-20000-25598	2466 N FLETCHER DR	90039	13	150A209    47	5437033009	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Expired	10/19/2016 12:00:00 AM	ADDRESS	34.10705	-118.25505	REPLACE EXISTING 600AMP OVER HEAD SERVICE WITH THREE DWP METERS OVERHEAD  SERVICE TO SERVE ADDRESSES 2466,2468, AND 2470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17397	14041-10000-27433	9122 N SANDUSKY AVE	91331	6	198B157   959	2625032013	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.23557	-118.42605	Installation of roof mounted solar PV system.  Total system size = 6.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17398	19041-20000-51332	13501 W OSBORNE ST	91331	6	198B157   204	2621022014	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.24148	-118.42719	New fire alarm system for (E) building.  (59) devices with FACP, cellular communicator, and voice evacuation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17399	11041-20000-03289	6701 N DARBY AVE	91335	3	180B125   188	2125014030	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			02/18/2011 12:00:00 AM	02/18/2011 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	ADDRESS	34.19237	-118.53362	Install sign for existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17400	15041-20000-09919	5555 N BONNER AVE	91601	2	174B173  1054	2350005005	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			PC Info Complete	12/30/2015 12:00:00 AM	ADDRESS	34.17159	-118.37432	Plan check for power and energy for new 31 unit residential building. 4 story and 2 parking story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17401	18041-10000-00168	285 W 6TH ST Unit #A	90731	15	015B201   799	7455021***	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM			Corrections Issued	01/03/2018 12:00:00 AM	ADDRESS	33.73849	-118.28317	Energy plan check for an existing RestaurantTenant Improvement. Scope includes new lighting and equipment. Total area is 1,120 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17402	11041-10000-04282	9100 W PICO BLVD	90035	5	132B169   885	4305001001	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	34.05509	-118.39011	ROOF MOUNTED PHOTOVOLTAIC SYSTEM. 3 phase system, 19.5 kw. 3 invertor , 105 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17403	12041-20000-21238	266 N QUADRO VECCHIO DR	90272	11	126B117   129	4416024052	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.04369	-118.55969	Roof mounted P.V. system for family dwelling 9.66KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17404	14041-20003-04466	2723 W 8TH ST	90005	1	132A201    11	5077020802	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.05787	-118.28484	Changes to approved set.  Relocation of 3 branch circuit loads (on LP1B and LP1A) and subfeeding 1 panel from another (LP2B fed from LP2A)  *****Previous Work Description*****  CHANGE OF USE; EXISTING 2-STORY RETAIL OVER PARKING TO CHARTER SCHOOL.BUILDING PERMIT 14016-10000-02954	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17405	17041-10000-27207	4521 N STERN AVE	91423	4	168B153   766	2271004005	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.15355	-118.43563	PC FOR PV SYSTEM 11.4KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. 40 PV MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17406	17041-20000-33474	12723 W WENTWORTH ST	91331	6	198B161   319	2629027017	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Closed	09/28/2017 12:00:00 AM	ADDRESS	34.23711	-118.41145	Plan check for power only. Install a temporary 500kVA 277/480V generator to feed existing loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17407	16041-10000-33484	22110 W HACKNEY ST	91304	12	192B101   483	2010023009	RS-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.22176	-118.60878	PV1 solar system installation to a single family home. Installing 18 sunpower panels with integrated microinverter rated at 345 watts each. Total system size 5.76 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17408	18041-20000-30705	5416 N SATSUMA AVE	91601	2	171B173    60	2416015005	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.16917	-118.3674	Plan check for Title 24 Energy only in Bakery use to manufacturing and accessory office T.I. Total area:4496 sq ft. B#17016-20000-04503	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17409	16041-10000-44627	10671 N EL DORADO AVE	91331	7	207B157   647	2620006009	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.26401	-118.42307	PV1 roof mounted solary sytem installation to a single family home. Installing a new central inverter rated at 3.0 KW and 16 solar modules and optimizers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17410	19041-10000-31951	6411 N FIGUEROA ST	90042	14	154-5A231 104	5493004027	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Apartment			08/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	34.11823	-118.18371	PC FOR FA SYSTEM FOR  APARTMENT. 1 FACP  AND 51 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17411	11041-20000-00820	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	04/05/2011 12:00:00 AM	ADDRESS	34.02224	-118.28008	T.I. to existing building.  Install general/emergency lighting partial of the ground level.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17412	15041-20000-02480	2468 E 7TH ST	90023	14	123A221    77	5189006043	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.03237	-118.21752	PV1, SFD. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. TOTAL OF 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17413	17041-10000-07393	734 E 3RD ST	90013	14	127-5A215  12	5163012004	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.04556	-118.23683	Plan check for Title 24 only in existing space retail T.I. Total area: 4155 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17414	11041-10000-16054	4292 S CRENSHAW BLVD	90008	8	114B185  1019	5024017035	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.00573	-118.33378	MCDONALDS TI INTERIOR REMODEL PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17415	13041-20002-03240	5077 N LANKERSHIM BLVD 1-130	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	34.1626	-118.37361	REVISIONS TO AN APPROVED SET OF PLANS.  ADDING NEW 1200 AMP DISCONNECT AND (1) 6 METER STACK FOR RETAIL SPACES WITH STUB OUTS.New 4-story, mixed use building.  3000 amp service.  Full Plan Check.  Variance to separate fire alarm plans has been filed.  (((Customer has a pre-printed check, fees may need to be verified before issuing permit.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17416	17041-20001-27543	11631 W VICTORY BLVD	91606	2	180B169  1019	2335012019	C1-1VL, RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM			PC Approved	03/15/2019 12:00:00 AM	ADDRESS	34.18685	-118.38564	PLAN CHECK ONLY FOR SUPPLEMENTAL CHANGES TO APPROVED SET, CHANGES TO ROOFTOP HVAC EQUIPMENT, ADDITION OF TWO 125A PANELS. CLOUDED CHANGES ONLYB#16014-10000-00298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17417	17041-20000-06622	13731 N SHABLOW AVE	91342	7	228B161   445	2580009001	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.32146	-118.41156	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 100A MSP.3.8kW ungrounded system. (15) 280W pv modules. Using a standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17418	12041-10000-22584	8611 S SEPULVEDA BLVD	90045	11	096B165   637	4122001006	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	33.95942	-118.39646	CHANGE OF USE FROM RETAIL TO DENTAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17419	13041-10001-30875	13180 W SAYRE ST	91342	7	228B157   463	2511020020	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.32225	-118.41998	Expedited RSES plan check per applicant request. (((PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 23 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17420	14041-10000-28381	3183 W WILSHIRE BLVD 1-449	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Apartment			10/14/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.06196	-118.29111	Title 24 plan check only.  Total area = 1,448 sq. ft.T.I. to existing retail space.  Lighting replacement one for one.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17421	16041-10000-18699	1026 S BROADWAY BLDG A	90015	14	126A209   140	5139014006	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	07/21/2020 12:00:00 AM	ADDRESS	34.04029	-118.25788	FIRST TIME TENNANT (THEATER ) INSIDE A FIVE STORY APT. BUILDING. PC FOR POWER AND ENERGY. TOTAL AREA 629 SQFT. REF TO CORE AND SHELL :  13041-10000-32351	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17422	15041-10001-41921	5926 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.10524	-118.18409	MODIFICATION ON APPROVED PLAN.  ADDITION OF 6 ADDRESSABLE RELAYS TO THE APPROVED FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17423	14041-20000-29629	9100 W ORIOLE WAY	90069	4	147B169   812	5560006024	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.09672	-118.38821	fee charge $0.00 by state senate bill no. 1222Roof mounted PV system with Optimizer.  Total system size 23.85 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17424	17041-20000-20399	17644 W ROMAR ST	91325	12	204B129   564	2734012054	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.25459	-118.51916	pv1install roof mounted pv system sized 5kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17425	16041-10001-27380	877 S FRANCISCO ST	90017	14	129A207   122	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.04791	-118.26383	PLAN CHECK ONLY. Supplemental to changes to previously approved set. Changes due to reduction in project costs. Changing feeders from copper to aluminum and reducing lengths. Changes clouded under delta E.Changes where already assesed by Mehdi, PC to verify and remove this sentence upon approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17426	17041-10002-45126	15285 W SUNSET BLVD	90272	11	129B125   591	4423016007	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM			PC Approved	08/24/2018 12:00:00 AM	ADDRESS	34.04704	-118.52517	Change to aproved set by updating the fault current on the single line diagram. All changes under delta-0 only.(((Full plan check for a first time tenant T.I . Scope includes new lighting and equipment with a new main 1200 Amp panel. Total area is 11,426 SQ FT.PER#17016-10000-37285 )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17427	17041-10000-09406	600 WORLD WAY WEST	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Closed	08/22/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	PC for T24 only for new lights in section M-19 of LAX airport lounge area. Total area is 3495 sqft. Total intalled load is under 400 A.*4303sf addition to e. terminal 6 including new holdroom, airline lounge, corridor, elevator, stairs and ramp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17428	13041-10000-01342	8156 W MELROSE AVE	90048	5	141B173   461	5528011004	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	PIN	34.08346465	-118.36725718	FIRE ALARM  SYSTEM. 34 DEVICES 1 PANEL. SINGLE STORY AND MEZZANINE RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17429	13041-10000-33451	707 E 4TH PL	90013	14	127-5A215  24	5163012015	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.04542	-118.23748	"INSTALLATION OF NEW FIRE ALARM SYSTEM FOR 2 BUILDINGS (BLDG ""A"" & BLDG ""B) LOCATED ON THE SAME PARCEL. SINGLE STORY BUILDING. WITH 16 DEVICES, 2 PANELS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17430	12041-20000-07864	5401 W SUNSET BLVD	90027	13	147A193    61	5544022054	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.09828	-118.30725	Tenant Improvement for a retail building. Single story commercial building. Plan check for energy and emergency lighting. 2958 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17431	16041-10000-34285	11105 S WILMINGTON AVE	90059	15	087A215    45	6069013016	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM			PC Approved	09/27/2016 12:00:00 AM	ADDRESS	33.93408	-118.23918	Plan check only. PC for energy only to fire damaged retail store. Scope of work includes new lighting and power. No outdoor lighting including. Total sqft = 2340**Permit has been paid under application number: 16041-70000-22011.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17432	18041-20001-14161	3831 S HUGHES AVE 104	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	34.02242	-118.39823	SUPPLEMENTAL CHANGES TO APPROVED SET. ADDING A NEW CHANDELIER AND REDUSING TYPE D LIGHTING FIXTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17433	11041-20000-25734	15355 W SHERMAN WAY B-D	91406	6	183B145    36	2222027039	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Closed	09/30/2014 12:00:00 AM	ADDRESS	34.20139	-118.46803	Restaurant remodelEnergy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17434	19041-10000-32027	110 E 9TH ST 4TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Energy plan check for a partial office T.I located on the 4th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 13,481-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17435	14041-20000-21838	5420 N YOLANDA AVE	91356	3	174B121   813	2161026004	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			08/13/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.16939	-118.54034	57  units Condo over Type I-A Garage.Fire alarm variance filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17436	14041-10000-17425	523 W 6TH ST Suite 1216	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Expired	08/04/2016 12:00:00 AM	PIN	34.04872199	-118.25441618	Title 24 plan check only.  Total area = 210 sq. ft.Install new lighting in existing commercial space.  No changes tto power equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17437	15041-20001-01669	4414 N PETIT AVE	91436	5	165B137   106	2284010003	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.15108	-118.49541	Fee for Expedite only.New roof mounted PV system with Microinverter (Enphase M250) and Power one Inverter.  Total system size 9.72KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17438	12041-10000-14645	2749 W 15TH ST	90006	1	129B193  1514	5075011023	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.04555	-118.30175	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17439	17041-30000-02249	3831 S HUGHES AVE	90232	5	120B165  1276	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.02242	-118.39823	Title 24 plan check.  T.I. to ground floor building entrance including garage ramp and lobby in existing commercial medical highrise.  Total area = 2,720 sq. ft.  Building permit #16016-20000-17436	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17440	17041-20001-28149	511 S KENMORE AVE	90020	10	135B197   809	5502020008	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.06497	-118.29682	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on apartment building.24.6kW ungrounded system (8.2+8.2+8.2). (97) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17441	16041-20000-06632	16407 W HAMLIN ST	91406	6	180B137   507	2231003028	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.18854	-118.49054	PV1. ROOFMOUNTED SOLAR SYSTEM. ADDITION TO EXISTING SYSTEM. ADDTION SYSTEM SIZE: 8.06KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17442	17041-10001-03043	310 W ORD ST	90012	1	133-5A215 144	5408015003	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.06006	-118.23885	Plan check for Title 24 only in existing space massage parlor T.I. Total area:725 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17443	16041-20000-45675	22901 W STYLES ST	91367	3	177B097   190	2039013042	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.18388	-118.62539	pv1install roof mounted pv system sized 7.2kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17444	14041-10001-11113	14313 W RUNNYMEDE ST	91405	2	186B153   219	2215023026	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.20585	-118.44501	((5/6/2014- Changes made to approved set. Added 2 modules and changed module manufacturer))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17445	12041-20000-24241	8201 N TOPANGA CANYON BLVD E	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM			Corrections Issued	11/13/2012 12:00:00 AM	ADDRESS	34.21793	-118.6063	relocate 2 x2  lighting.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17446	19041-20000-11027	12424 W WILSHIRE BLVD ste 640	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM			PC Approved	03/27/2019 12:00:00 AM	ADDRESS	34.04135	-118.47058	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17447	13041-10000-21815	2861 W SUNSET BLVD	90026	13	142-5A205 705	5426002031	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.08287	-118.27296	TI for existing 1373 sq ft restaurant in single story building.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17448	13041-10000-29415	2018 N HIGHLAND AVE	90068	4	150A185    63	5575023004	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.10715	-118.33728	PLAN CHECK FOR POWER AND ENERGY. NEW BUILDING . HOTEL WITH 20 GUEST ROOMS.  BUILDING PERMIT # 13010-10000-03238	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17449	14041-20000-13853	6430 W SUNSET BLVD 504/505	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	pc for T24 energy only. total area 2879 sq ft. offices. new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17450	14041-20001-12790	13226 W CANTARA ST	91605	2	192B157  1031		(T)RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM			PC Approved	08/08/2014 12:00:00 AM	ADDRESS	34.21969	-118.4209	Modification to approved set.  Derating of main breaker to house MSP due to center-fed panel bus configuration.  $0 submittal fee is due to Senate Bill SB-1222. (((Roof mounted PV system with system size 8.25KW.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17451	19041-20000-28110	3341 N TARECO DR	90068	4	159B181   634	5579030026	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.12987	-118.34357	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.84KW DC/10.08KW AC. SCOPE OF WORK INCLUDES (32) SUNPOWER SPR-X22-370-E-AC PV MODULES WITH INTEGRATED MICROINVERTERS, AND A 100A SOLAR SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17452	10041-10000-19754	13520 W PAXTON ST A-2	91331	7	210B157  1074	2535002015	M3-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	34.27356	-118.42606	REMODEL PANDA EXPRESS RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17453	16041-10000-13061	1150 S OLIVE ST SUITE1325	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2562.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17454	15041-10000-03557	3524-3528 W SUNSET BLVD	90026	13	144A203   167	5427025008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			Not Ready to Issue	08/02/2016 12:00:00 AM	ADDRESS	34.08924	-118.27686	TI to (E) 414 sq ft. restaurant space.  Plan check for energy.Permit is obtained under 15041-40001-03557	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17455	13041-10000-34779	1100 N BANNING BLVD 1-46	90744	15	033B209   587	7423020046	RD6-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Apartment			12/13/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	33.78533	-118.25813	INSTALLATION OF A NEW FIRE ALARM SYSTEM. EXISTING BUILDING WITH NO SPRINKLERED SYSTEM. 2 STORY BUILDING. BUILDING A WITH COMMUNITY CENTER. 1 FACP WITH 4 RPS, AND 110 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17456	10041-10001-05995	1864 W CORDOVA ST	90007	1	126B197   862	5075029009	R3-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Apartment			04/29/2010 12:00:00 AM			PC Approved	04/29/2010 12:00:00 AM	ADDRESS	34.0389	-118.29934	INSTALL ELECTRICAL WALL HEATER. ; PERMIT WAS OBTAINED ON 10041-10000-05995	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17457	12041-20000-13922	6300 S CRENSHAW BLVD	90043	8	105B185   892	4006010006	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.00	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	33.98271	-118.33064	Change of use from retail to laundromat.  New 800A service, main panel, and subpanels.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17458	17041-20000-29719	11241 N RANETTO PL	91342	7	210B181    95	2550021007	RE11-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Issued	08/28/2017 12:00:00 AM	ADDRESS	34.27421	-118.34648	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 7.6 kWac and consists of (1) inverter, (27) modules, (1) load center, and (1) Tesla Powerwall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17459	14041-10000-04818	6333 W 3RD ST BLDG E	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.07157	-118.36014	TI in an existing retail clothing store.  Plan check for Title 24 for changes to lighting system. All circuits and panels EXISTING to remain. One new upgraded feeder to an existing panel. No new loads added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17460	14041-20000-14275	2530 N VASANTA WAY	90068	4	154-5A189 494	5585010001	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	PIN	34.11563297	-118.3237399	PV1.  Install 5.3 kW roof-mounted utility-interactive PV system.  Transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17461	19041-10000-06524	380 WORLD WAY TBiT-Starbucks	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Info Complete	03/05/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC T-24 ONLY FOR EXISTING STARBUCKS ADDING NEW TRACK LIGHTS. AREA 725-SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17462	16041-20001-43893	23218 W COLLINS ST	91367	3	174B093   283	2041011030	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/18/2016 12:00:00 AM	ADDRESS	34.17356	-118.63269	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 400A MSP.15.2kW (7.6+7.6) ungrounded system. (53) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17463	15041-20000-37735	21031 W VENTURA BLVD Suite 920	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Issued	11/20/2015 12:00:00 AM	PIN	34.16717222	-118.59179488	Plan check for energy only. TI to existing office on 9th floor of high rise office building. New lighting (incl. emergency) and receptacles. 1,576 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17464	17041-20001-45252	14024 W FILMORE ST	91331	6	204B153   175	2617004044	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.25881	-118.43911	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.05KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17465	18041-20000-28200	4622 N TOWNSEND AVE	90041	14	159A225   220	5476004026	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.12819	-118.20377	Plan check for PV roof mounted system, system size: 7.6KW with 20 modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17466	10041-20000-02179	13571 W VAUGHN ST	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.27758	-118.42846	Plan check power and energy for tenant improvement - remodel of (E) warehouse building with over 400A new load. In methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17467	16041-10000-14221	1113 S MEYLER ST	90731	15	015B197  1304	7458013024	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	33.73398	-118.2969	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 6.0KWac.(25)MODULES-SUNIVA-OPT 280-60-04-1BO(25)MICROINVERTERS-ENPHASE M250-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17468	16041-10000-25768	5800 W SUNSET BLVD stage 6	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	Installation of a new fire alarm to KTLA stage. Installing (248) fire alarm devices. (4) Control panels. (1) Communication panels. (1) Fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17469	19041-10000-48360	2645 S GLENDON AVE	90064	5	123B157   272	4255015029	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	07/01/2020 12:00:00 AM	ADDRESS	34.03569	-118.42387	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 4.81KWdc (4.16KWac) USING 13 SP X22-370 AC MODULES AND ESS TESLA POWERWALL.CONNECTED TO A 200 AMP EXISTING SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17470	15041-10000-19900	10780 W SANTA MONICA BLVD STE #330	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.0504	-118.43387	Energy plan check for a financial office T.I ; Scope include new lighting and receptacles. Total area is 7729-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17471	18041-30000-34698	633 W 5TH ST 19TH FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	PLAN CHECK FOR T24 ONLY,  INTERIOR OFFICE TENANT IMPROVMENTS; NO CHANGE OF USE OR ADDIDTION. WORK TO BE DONE ON THE 19TH FLOOR. AREA: 20,985 SQ.FT(B# 18016-10000-28622)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17472	13041-10001-25123	1425 N NAUD ST	90012	1	136-5A217 155	5409004012	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM				Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17473	17041-10000-14424	400 E 2ND ST	90012	14	129A215   190	5161019011	[Q]C2-3D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.04698	-118.23925	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new LED ones.Area: 42,000 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17474	11041-10005-10270	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.14947	-118.43885	changes made to previously approved set. see fee schedule.PLAN CHECK ONLY FOR REVISION R2. REVISE FEEDER SIZE FOR LK/LKA  PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17475	15041-10000-31141	1800 S AVENUE OF THE STARS	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	T-24 for an exisiting apartment building, scope of work is being done in Boiler room. Adding new panels, lighting, and motors connected to a 400 amp fuse. PC for energy only. Sq Ft = 520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17476	12041-10000-15061	1600 N WESTERN AVE	90027	13	148-5A193 302	5544022035	[Q]R5-2	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			06/28/2012 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.10004	-118.30899	Plan check power and energy for new 4-story 40 unit apartment with 1600A service. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17477	19041-10000-13592	8373 S WESTLAWN AVE	90045	11	096B161   479	4112028008	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	33.96104	-118.40638	PV1, Roof mounted solar system using central inverters with solar optimizers. (13) modules and optimizers and (1) 3800 Inverter. Total system size is 3.8KWAC, 4.225 KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17478	19041-10000-44174	909 E COLON ST	90744	15	036B209   293	7426003001	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	33.79161	-118.25174	PC FOR POWER ONLY FOR A NEW LISTED TRAILER UNIT 1200A MCC WITH NEW MOTORS AND CONTROLS CONNECTED TO A 4000A EXISTING SWITCHBOARD. COMPLY WITH DEPARTMENT ORDER effective date09/23/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17479	17041-10000-31003	2527 S SAN PEDRO ST	90011	9	120A207   301	5127010024	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	10/29/2017 12:00:00 AM	ADDRESS	34.02207	-118.26127	PC FOR  take out restaurant and T.I., (1100sf) (Change of use from medical office).FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS RECEPTACLES AND CIRCUITS. TOTAL AFFECTED AREA 920 SQ.FT. BLDG # 17016-10000-18812	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17480	16041-20000-14831	9237 N SAN FERNANDO ROAD	91352	6	198B169   139	2631003020	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.23695	-118.39155	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 10938.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17481	16041-20002-26899	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.32381	-118.49103	Revisions to approved set of plans.  Miscellaneous changes to lighting system, some additional receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17482	15041-10000-07921	3650 W MARTIN LUTHER KING, JR BLVD Ste 103	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	Tenant build out of Total Woman Gym within existing tenant space of Baldwin Hills Crenshaw Plaza.  Assembly occupancy with proposed occupant load of 144.  Full plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17483	18041-20000-05000	18938 W VENTURA BLVD	91356	3	174B121   466	2161001037	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.17229	-118.5461	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade and feeding new and existing distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17484	19041-20000-22650	11817 N DARBY AVE pv1	91326	12	216B125   248	2870020016	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.28696	-118.535	pv1install roof mounted pv system sized 7.6KW AC interconnecte with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17485	14041-20000-16721	1340 E 6TH ST 5th Floor	90021	14	126A217   152	5164011001	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	12/26/2014 12:00:00 AM	ADDRESS	34.03813	-118.23423	"Convert entire 5th from warehouse to manufacturing on the existing building.  Install tenant panels, branch circuits, and lighting.  Plan check for power and energy.""COMPLY WITH DEPARTMENT ORDER effective date03/17/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17486	17041-20001-26205	905 E 2ND ST #108	90012	14	129A215   387	5163003063	(T)(Q)C2-2D-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.04729	-118.23499	3/29/2018changes to an approved set of plans.  changes include revisions to lighting plan and energy calculations. this is plan check only.(((Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 4,880 sq. ft.Note: Building application has been generated under 17016-10000-11345)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17487	11041-10000-20599	650 S HILL ST #604	90014	14	129A211   215	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM	09/27/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.04623	-118.25392	TI IN AN EXISTING OFFICE AREA IN SUITE # 604.  PLAN CHECK IS FOR T-24 ENERGY CALCS.   PERMIT IS FOR RELOCATED LIGHT, SWITCHES AND COMMUNICATION / DATA OUTLETS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17488	18041-20000-29452	18247 W SHERMAN WAY	91335	3	183B125   102	2119028007	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	02/08/2021 12:00:00 AM	ADDRESS	34.20134	-118.53122	One-for-one LED retrofit of (E) commercial retail store.  Plan check for energy - 22,333 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17489	17041-10000-43422	1713 S WESTERN AVE	90006	10	126B193  1421	5073012034	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.04227	-118.30925	T-24, CHANGE OF USE FROM RETAIL TO RESTAURANT.  TENANT IMPROVEMENT IN AN EXISTING SHELL BUILDING FOR A NEW FAST FOOD RESTAURANT.  SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1755	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17490	19041-10000-23243	1547 S CORINTH AVE	90025	11	129B149   434	4261004903	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	04/17/2020 12:00:00 AM	ADDRESS	34.04653	-118.45014	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17491	12041-10000-19358	8476 W COLE CREST DR	90046	5	148-5A173 120	5556016009	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	11/02/2012 12:00:00 AM	ADDRESS	34.1027	-118.37575	Plan check new roof mounted 11.5KW DC photovoltaic system for single family dwelling. (5 strings to an inverter)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17492	17041-10001-29684	3407 E 4TH ST	90063	14	124-5A227 346	5179013041	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2039.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.03397	-118.19652	Supplemental for changes to approved set. Relocating three new panels on roof.**PC FOR SFD PV SYSTEM. TOTAL SIZE 3.8KW AC USING CENTRAL INVERTER WITH 14 MODULES, USING POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17493	15041-10000-31334	9149 S WESTERN AVE	90047	8	094-5A193 159	6036016052	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	33.95324	-118.3092	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 9748.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17494	11041-20000-24539	1442-1444 S SPAULDING AVE	90019	10	129B177   809	5069011026	R2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2011 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.04945	-118.36271	New 5.7 KW roof mounted PV system for a duplex.  Applicant is uning the ENPHASE M215 microinveter.  A variance has been filed for their use.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17495	12041-20000-14356	3650 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.02081	-118.28964	T.I. to USC (Olin Hall of Engineering) on Basement and 3rd floor of IT rooms.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17496	16041-10000-34583	120 N ROBERTSON BLVD STE 202A	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.07585	-118.38356	TI REMODEL FOR AN EXISTING HIGH RISE BUILDING (NEW OFFICE SPACE)TITLE 24 SQ. FT. (2696)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17497	16041-20000-02466	11707 W EL CERRO LANE	91604	2	159B169   464	2381002013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.13151	-118.38799	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (32) modules, and (1) load center. System is interconnecting with a 400-amp MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17498	19041-20000-08137	1809 S MESA ST LOT 13	90731	15	012B201   788	7456029039		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	33.72763	-118.28613	PLAN CHECK FOR NEW SOLAR ROOFMOUNT PV SYSTEM 3.015KW DC/2.88KW AC, SCOPE OF WORK INCLUDES (9) SUNPOWER SPR-X21-335-BLK-D-ACPV PANELS WITH INTEGRATED MICROINVERTERS, ON A NEW SFD TOWNHOUSE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17499	18041-10000-02461	5433 N SAN FERNANDO ROAD WEST	90039	13	165B201    86	5593008008	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.1511	-118.2751	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17500	17041-10000-18499	6500 N SEPULVEDA BLVD	91411	6	180B145   564	2235002007	R4-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	34.1886	-118.46595	PLAN CHECK FOR POWER AND ENERGY FOR (N) 6-STORY 160-UNIT TYPE III-A APT W/ TYPE 1-A BASEMENT PARKING. SCOPE OF WORK INCLUDES 4000A SERVICE. TOTAL T-24 AREA 113500 SQ. FT. (16 TYP UNITS). B#16010-20000-05719	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17501	13041-10000-23156	5636 N LUBAO AVE	91367	3	174B113   300	2153017020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.17348	-118.5672	ROOF-MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL, SYSTEM SIZE:5.39 KW DC, 5 KW AC, IN A SINGLE-STORY HOME.(22) MODULES:TRINA SOLAR #TSM0245PC05/PA05.18(1) INVERTER: SOLAREDGE #SE5000A-US(22)POWER OPTIMIZERS: SOLAREDGE #OP250-LV-MC4SM-2NA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17502	14041-20000-17355	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.15777	-118.43065	TI to (E) school building.  Remodeling of 2 gym spaces, administrative offices, and patio.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17503	15041-20001-32712	13202 W CHANDLER BLVD	91401	4	171B157   126	2345022020	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.16825	-118.42036	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (70) modules, (1) combiner box, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17504	14041-20000-21794	6873 N TROOST AVE	91605	2	183B169   436	2320011015	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.19599	-118.38665	Plan check for Title 24 with new service upgrade to 400 Amp on an auto body shop building. Total area is 3020 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17505	19041-20000-45030	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005021	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.15303	-118.39667	Plan check for (48) EV Charger, (2) 400A 120/208 Volt 3PH  Distribution and 1 Transformer 150KVA feed from Existing 800A 277/480 Volts distribution. ************************School parking lot EV Charger system. ******************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17506	16041-10000-20127	9301 N TAMPA AVE #17	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC for T-24 only, TI on (E) commercial build., combine 3 spaces into 1. New connected load < 400. Total area: 4,360 sq. ft.B# 16016-10000-13245	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17507	15041-10001-18138	12777 W JEFFERSON BLVD	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	33.9778	-118.41768	01/21/16Changes to an approved set. All changes are clouded under delta 1. Changes include temporarily powering the 5 story building from existing building's 'B' 3000A main switchboard.Note: original application under PCIS#15041-10000-18138 ((((FULL PC, POWER AND ENERGY. NEW 5 STORY PARKING STRUCTURE. LOCATED IN METHANE ZONE WITH UNDERGOUND SERVICE. TOTAL SQ. FT. 224,153.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17508	19041-20000-37915	19951 W VENTURA BLVD	91364	3	174B113   382	2164001018	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.17225	-118.56772	PV PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS27.06 KW DC/30.24KW AC. SCOPE OF WORK CONSISTS OF (82) PV MODULES WITH (42) MICROINVERTERS AND A NEW 200A PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17509	12041-10000-29960	11150 W SANTA MONICA BLVD 2ND FLOOR	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN AN OFFICE ON A HIGH RISE. PARTIAL 2ND FLOOR OF BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17510	19041-20001-26481	1921 S VIRGINIA ROAD	90016	10	126B185  1052	5061005003	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM			PC Approved	08/12/2019 12:00:00 AM	ADDRESS	34.03929	-118.33577	08-12-2019 Changes to an approved set of plan, Changes include relocate PV Module on roof. Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17511	16041-20000-45460	4673 N ARRIBA DR	91356	3	168B121   403	2176024024	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.15501	-118.5451	PV1.  Install 7.7 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17512	19041-20000-52780	693 E MILFORD ST	90042	14	150A233    22	5312023036	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Hermon	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.10673	-118.17944	Plan check for PV roof mounted system, PV system size: 7.56KW with 24 PV Modules and 1 inverter(7.6KW) and Energy Storage System size: 40.5KWh, with 3 Energy Storage Device(13.5KWh)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17513	19041-20002-32641	12653 W OSBORNE ST BLDG GSA	91331	7	204B161     2	2536017906	OS-1VL-CUGU, PF-1VL-O-CUGU, [Q]MR2-1VL-O-CUGU, [T][Q]MR2-1VL-O-CUGU	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Approved	12/03/2019 12:00:00 AM	ADDRESS	34.25491	-118.40888	Revision to approved plans.  Change of module type, count, and optimizer.  Revised system is 59.13 kW DC / 52.10 kW AC CEC.  (162) modules with P730 optimizers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17514	13041-20000-29883	5250 N LANKERSHIM BLVD 2nd FLOOR	91601		171B173   367	2350018086							Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.16668	-118.37545	T24 FOR EXISTING HIGHRISE SCHOOL. SCOPE OF WORK ON THE 2nd FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17515	14041-10000-23898	201 N LOS ANGELES ST	90012	14	130-5A213   3	5161014901	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.0529	-118.24156	PC FOR POWER. UPGRADING EXISTING CARWASH. EXISTING LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17516	15041-10001-27136	22520 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM			Not Ready to Issue	03/04/2016 12:00:00 AM	ADDRESS	33.82142	-118.30137	Install rooftop solar system 1.72kW AC   (8) modules 250W-STC and (8) EnphaseM215.Permit under 15041-90000-27136	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17517	14041-10000-05196	5031 W LEMON GROVE AVE	90029	13	141B193    66	5535024001	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.08636	-118.30617	PV1.  Install 3.75 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US-ZB-U.  15 modules: Canadian Solar CS6P-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17518	14041-20002-12431	6554 N BONNER AVE	91606	2	180B173   554	2336003002	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM			PC Approved	07/14/2014 12:00:00 AM	ADDRESS	34.18993	-118.37358	CHANGE IN PLANS. ADDED NEW AC DISCONNECT OUTSIDE OF LOCKED GATE. PLAN CHECK FOR NEW DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17519	19041-10000-52926	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.08469	-118.4849	[EPLAN] PV2, NEW ROOF-TOP SOLAR INSTALLATION 32.1KWdc (22.8KWac & 29.7KWcec-ac) USING 57 QP400, 30  HELIENE 60 MBLK-310  MODULES, 57 SE P400 & 30 SE P320 POWER OTIMIZERS &  2 SOLAREDGE  SE7600A-US & 1 SOLAREDGE SE7600H-US CENTRAL INVERTERS. CONNECTED TO A 600 AMP EXISTING SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17520	19041-20000-24170	6038 N JUMILLA AVE	91367	3	177B117   572	2153021013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Issued	06/24/2019 12:00:00 AM	ADDRESS	34.18041	-118.56352	PLAN CHECK FOR INSTALLATION OF A 27 KWH ENERGY STORAGE SYSTEM ON EXISTING SFD WITH EXISTING PV. SCOPE OF WORK INCLUDES (2) 13.5KWH TESLA POWER WALLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17521	15041-20000-29554	8716 N NOTTINGHAM PL	91325	12	195B133   530	2690010024	[Q]RD4-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	11/07/2015 12:00:00 AM	ADDRESS	34.22911	-118.50299	Plan check for PV roof mounted system. System size: 6.0kW with 23 modules and 1 inverter(6.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17522	19041-10000-30030	137 W 60TH ST	90003	9	105B201   473	6005015019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.98524	-118.27528	PV1 NEW ROOFOTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10.07 KWdc/10KWac. SCOPE OF WORK IS 33 MODULES (HANWGA Q-PEAK 305) WITH OPTIMZERS (SE-P320) AND A CENTRAL INVERTER (SE10000H-US). PANEL UPGRADE WILL BE PULLED UNDER A SEPERATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17523	17041-10001-43575	19515 S VERMONT AVE	90502	15	057B197    23	7351034023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Info Complete	03/14/2018 12:00:00 AM	ADDRESS	33.85325	-118.29073	VOID, PC WIll BE REDONE ON A NEW APP#Supplemental PC for T24 only for revisions. Connecting circuits to panel HA and LC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17524	18041-10000-28077	12800 W ZANJA ST	90066	11	111B153  1201	4236021021	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			07/26/2018 12:00:00 AM	06/10/2019 12:00:00 AM		Issued	06/10/2019 12:00:00 AM	ADDRESS	33.99696	-118.43833	*SEE APPLICATION COMMENTS***PC FOR POWE AND ENERGY FOR New 4 story, 10 unit, Type VA, apartment building over 1 level subterranean parking garage. NEW SERVICE RATED AT 1000A 120/208 3PHTOTAL AFFECTED AREA **TBD*** 22000SQ.FT (INDOOR + OUTDOOR)B# 18010-10000-00355	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17525	13041-10000-31525	11675 FLORENCIA WAY	91326	12	216B109    92	2701076062	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Info Complete	11/19/2013 12:00:00 AM	PIN	34.28448756	-118.58530523	PV1, Install 4.75 kW DC roof-mounted solar array for a 2-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 19 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17526	19041-10001-11101	20200 W SEPTO ST	91311	12	201B113   116	2741017019	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.25077	-118.57342	Changes to an approved set of plans. Changes include relocating the PV modules on the roof-layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17527	18041-10000-21987	2029 S CENTURY PARK EAST 9th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN EXISTING RESTROOMS ON THE 9TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17528	18041-20001-23619	410 E 68TH ST	90003	9	102B205   260	6011011018	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2018 12:00:00 AM			PC Approved	07/13/2018 12:00:00 AM	ADDRESS	33.97779	-118.26708	07/13/2018 Changes to an approved set of plans. Electrical equipment has been relocated. New locations are indicated on the plan set. *****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (25) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17529	16041-20000-14271	1410 N TANAGER WAY	90069	4	147B169   748	5561024007	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM			PC Info Complete	05/27/2016 12:00:00 AM	ADDRESS	34.09708	-118.38525	Plan check for power only. New 3-story, 12,750sqft SFD. 800A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17530	17041-10000-46592	4691 E HUNTINGTON DR NORTH	90032	14	142-5A231  12	5213012042	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.08641	-118.18445	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17531	10041-10000-11801	16693 W ROSCOE BLVD UNIT A	91343	6	192B137   311	2205002901	[Q]M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		9800.08	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM	06/28/2010 12:00:00 AM		Issued	06/28/2010 12:00:00 AM	ADDRESS	34.22051	-118.49689	TI EXIST RETAIL KITCHEN SHOW ROOM.  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17532	15041-10000-20281	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			Verifications in Progress	07/15/2015 12:00:00 AM	ADDRESS	34.07157	-118.36014	PLAN CHECK FOR POWER AND ENERGY TO FIRST TIME TENANT RETAILS CONNECTED TO AN EXISTING 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17533	19041-20000-39839	16618-16620 W MARQUEZ AVE	90272	11	129B121   674	4415006009	C1-1XL	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Issued	10/07/2019 12:00:00 AM	ADDRESS	34.04795	-118.54411	Power and lighting for TI to (E) retail spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17534	13041-10000-28934	527 S LUCERNE BLVD	90020	4	135B189   728	5505020012	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.06458	-118.32459	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN RESIDENTIAL UNIT. INTERCONNECTING WITH EXISTING 200A MAIN. SYSTEM SIZE IS 5.62 KW AC . WORK IS PERFORMED ON THE MICROINVERTER STANDARD PLAN WITH (26) ENPHASE-M215 MICROINVERTERS AND  (26) LG285N1C-G3 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17535	12041-20000-15382	14301 W MILLBROOK DR	91423	5	162B153    21	2274001027	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.14438	-118.44464	photovoltaic system on roof of single family dwelling, Install two inverters, 45 modules, solar subpanel, and service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17536	17041-20000-05831	9255 N RESEDA BLVD A & B	91324	12	198B125   207	2763009001	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/06/2017 12:00:00 AM		Permit Closed	11/01/2017 12:00:00 AM	ADDRESS	34.23878	-118.53628	Addition to rear of (E) take-out restaurant.  Plan check for energy.Permit for (2) new branch circuits issued previously under 16041-20000-05831.  Additional permit fees levied to capture the additional work to be performed (new panel and add'l circuits)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17537	19041-20000-31965	8744 N REMMET AVE	91304	3	195B105   184	2779041034	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.22948	-118.60011	PV2.  Install 22.57 kW dc grid tied PV system on carport.  (74) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17538	17041-10002-00489	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.20103	-118.38536	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 5 ON PLANS. CHANGE TO NOTE 8. CLARIFIED CABLE LIMITERS TO BE ON LINE SIDE OF MAIN DISCONNECT AS SHOWN ON SINGLE LINE DIAGRAM. NO OTHER CHANGES. PC ONLY. PERMIT STILL UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17539	13041-10000-08779	845 S LOS ANGELES ST	90014	14	126A211    15	5145014003	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	04/19/2013 12:00:00 AM	ADDRESS	34.04126	-118.25361	TITLE 24 PLAN CHECK. ENERGY ONLY. WORK TO BE DONE ON 1ST FLOOR. RETAIL SPACE. TOTAL AREA 5,971 SQ. FT. MEN'S CLOTHING. PERMIT TO BE ISSUED BY PLAN CHECK STAFF ONLY. PART OF HIGHRISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17540	14041-20000-27563	16648 W BIRCHER ST	91344	12	213B137   352	2610024017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Expired	10/31/2016 12:00:00 AM	ADDRESS	34.28148	-118.49449	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(24) SolarEdge P300 power optimizers(24) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17541	15041-20000-43995	201 N FIGUEROA ST 13th Floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for Title 24 only. Project site is an existing commercial, high-rise building. Project scope is a tenant improvement to the 13th floor. Total lighting area = 1,674 sq. ft.Note: Building permit has been pulled under 15016-10000-18045	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17542	13041-10000-06091	14431 W BURBANK BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.17235	-118.44762	T24 FOR EXISTING STARBUCKS. NEW CONNECTED LOAD IS LESS THAN 400A. SQRFT 1033. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17543	14041-10000-07641	12655 W BEATRICE ST	90066	11	105B157   658	4211006017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	33.98007	-118.41764	TI TO REMODEL 4409 SF OF EXISTING OFFICE/MANUFACTURING SPACE PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17544	18041-10001-03811	900 N NORTH BROADWAY #1070	90012	1	135A215   238	5414013901	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.06408	-118.23726	PC for power and energy for first time wine bar tenant. Installing new lights, receptacles and water heater.B#17016-10000-33241	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17545	15041-10000-28374	901 S PACIFIC AVE	90291	11	108A143    94	4286026011	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Expired	10/19/2017 12:00:00 AM	ADDRESS	33.99137	-118.47538	PC for T-24, TI to a commercial site (small coffee shop). Scope of work: new lighting and receptacles.  Sq ft = 442.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17546	15041-20000-02628	1989 N LINDA FLORA DR	90077	5	150B145   186	4377005004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Expired	02/28/2017 12:00:00 AM	ADDRESS	34.10649	-118.46632	""" 0$ fees due to senate bill 1222 ""Ground mounted PV system with total system size 15KW.Note: Resubmit due to lost plans"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17547	18041-10001-40459	3321 S LA CIENEGA BLVD	90016	10	120B173   176	4205033007	(T)(Q)C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			04/02/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.0275	-118.3723	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE ADDING 221 FIRE ALARM MODULES AND 1 NEW PANEL FOR SMOKE CONTROL ACTIVATION. NOTE: THE MODULES ARE PART OF THE SMOKE CONTROL SYSTEM. CONTROL SYSTEM WILL BE INTERFACED WITH THE FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17548	16041-10000-38488	1227 W MANCHESTER AVE	90044	8	097-5A197 302	6033013037	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Apartment			10/31/2016 12:00:00 AM			Reviewed by Supervisor	12/09/2016 12:00:00 AM	ADDRESS	33.96018	-118.29685	Plan check for New 14 units appartment Building. 1,200 A Service Delta configuration.**Note: Verify building application#	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17549	14041-20001-14187	14505 W FORTUNA LANE	91402	6	198B149   635	2644030215	(T)(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.24234	-118.44837	Changes from previously approved plans.  Install a new electrode grounding rod at the inverter.  No changes in module and inveter model numbers.  Note: Permit is under the original application.*****Previous Description*****pv1 single family dwelling. total system size 3.8 kw ac using nonstnadard plan. using transformerless inverter with power optimizers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17550	19041-20000-22957	19601 S HAMILTON AVE	90502	15	057B197    81	7351033023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	03/18/2021 12:00:00 AM		Permit Finaled	02/23/2022 12:00:00 AM	ADDRESS	33.85319	-118.28624	Plan check for power only, Service upgrade to 4000A 277/480 Volts to sub feed the existing distributaion equipment in the maufacturing/Office Building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17551	14041-20000-02004	4600 E CLELAND AVE	90065	1	151-5A221 118	5464001019	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.11042	-118.21752	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17552	15041-20000-42766	17000 W ROSCOE BLVD	91406	6	192B133   263	2204033016	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	PIN	34.2208709	-118.50295585	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR FOOD MART. 2040 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17553	13041-10001-33089	2800 N PHELPS AVE	90032	14	139-5A233  11	5217005012	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.07845	-118.17706	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17554	19041-20000-15600	2931 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.10446	-118.2438	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17555	13041-10001-30037	2110 W 7TH ST	90057	1	132A203   100	5141018002	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	ADDRESS	34.0565	-118.27737	PLAN CHECK FOR POWER ONLY. SERVICE UPGRADE FROM 400 AMPS TO 600 AMPS. TITLE 24 ENERGY PLAN CHECK PREVIOUSLY DONE UNDER 13041-10000-20742. CARLS JR RESTAURANT. Permit is existing this plan check only>>> this supplemental is for replacing pull section with UL approved one  Delat 3 only, existing gear complies with fault current-- no other changes , ---	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17556	12041-10000-29913	12760 W MILLENNIUM BLDG A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			01/23/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	PLAN CHECK POWER AND ENERGY FOR NEW 4-STORY 100 UNIT APARTMENT COMPLEX. BUILDING 'A'. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED. BUILDING LOCATED IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17557	19041-20000-01281	20039 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Closed	03/18/2021 12:00:00 AM	ADDRESS	34.27566	-118.57078	Plan check for power only for temporary generator feeding existing load/ Switch Gear rating  800A 277/480Volt, Generator rating 455KW/569KVA 277/480Volt. 600A Main Disconnect B#18016-10000-16954	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17558	10041-10000-07538	3400 E I ST	90744	15	033B217   921	7429013279		Harbor				2947.00	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM	06/25/2010 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	33.78294	-118.2214	INSTALL TWO NEW 25 HP COMPRESSOR MOTORS FOR A CNG DISPENSSER. ORIGINAL EPC # 09041-10000-07664	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17559	16041-10000-17934	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			PC Info Complete	08/01/2016 12:00:00 AM	ADDRESS	34.07196	-118.24719	PC for  energy only. Installing new outdoor lighting going from HID to LED light fixtures on level 9 corridor of Dodger Stadium. Total sqft  45476.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17560	17041-10000-25162	16737 W RINALDI ST	91344	12	213B137   570	2610013004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.27948	-118.49699	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(13)MODULES-SOLARWORLD 290 MONO BLACK(13)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17561	15041-10001-20764	600 WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			PC Approved	08/28/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	((8/28/2015- CHANGES MADE TO APPROVED SET. REMOVED EXIT SIGNS. NOT REQUIRED PER FIRE MARSHALL INSTRUCTION))ALTERATION OF AN OPEN AREA TO A DUTY FREE STORE DFS T6PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17562	15041-10000-03631	432 S CURSON AVE TOWER 50-50-04L	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.0673	-118.35362		N	N	Express Permit	06/10/2024 12:00:00 AM
17563	15041-10000-09949	5375 N SAN FERNANDO ROAD WEST	90039	13	165B201    99	5593008007	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Issued	04/03/2015 12:00:00 AM	ADDRESS	34.15034	-118.27471	PLAN CHECK FOR ENERGY ONLY. TI FOR EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17564	16041-20002-30272	18903 W RINGLING ST	91356	3	171B121   498	2176010009	RA-1	South Valley	Encino - Tarzana	Tarzana		1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	PIN	34.16229368	-118.54458786	Revisions to approved plans.  Relocation of equipment to opposite side of house by MSP, revisions to single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17565	15041-10001-06523	6232-6256 N TOPANGA CANYON BLVD BLDG C&D	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.18412	-118.60489	(((7/9/2015- CHANGES MADE TO APPROVED SET. ADDING NOTE 21 TO ALL THE TENANT SPACES. CALCULATIONS TO BE REVERIFIED. ALL PERMIT FEES FOR REVISIONS ARE ON BUILDING A APPLICATION 15041-10001-06518)))NEW FIRE ALARM SYSTEM IN BUILDING C,D ON WESTFIELD PLAZA. 200 DEVICES AND ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17566	10041-10001-24460	1408 W WASHINGTON BLVD	90007	1	126A201   178	5056026040	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2217.10	Electrical	Electrical	Apartment			04/19/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.0398	-118.28697	Revision to approved plans to delete generator and replace it with a central battery inverter system. Revise wiring to (2)  lighting panels and (1) elevator previously supplied from deleted generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17567	15041-20001-06572	18970 W BRASILIA DR	91326	12	216B121   364	2872010004	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM			PC Approved	04/07/2015 12:00:00 AM	ADDRESS	34.28763	-118.54388	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 11kW (6+5). Ungrounded system. (51) 255W pv modules each with a 300W power optimizer.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17568	16041-10001-01595	5735 W ADAMS BLVD	90016	10	123B173   824	5048005039	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM			PC Approved	02/22/2016 12:00:00 AM	ADDRESS	34.03262	-118.36814	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROO FMOUNTED PV SYSTEM SIZED 17KW INTERCONNECTED WITH MSP.(68) SOLARWORLD 285 MODULES(68) ENPHASE 250 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17569	19041-20000-21956	11150 W OLYMPIC BLVD ste 670	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.03956	-118.43857	ti to an existing commercial building ( high rise).  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17570	18041-10000-49025	400 W WORLD WAY T4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	PIN	33.94094587	-118.40577128	Energy plan check for a COMMERCIAL TENANT IMPROVEMENTS. Scope includes new lighting and equipment with a total area of 5926-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17571	19041-10000-45905	9105 N MORNING GLOW WAY	91352	7	195B181   118	2403027028	RE20-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.23416	-118.34586	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 20  (POWERXT 360R-PD) MODULES, 20  (SOLAREDGE P400) OPTIMIZERS, 1 (SE7600H-US) CENTRAL INVERTER, 1 TELSA POWERWALL, CONNECTED TO A NEW 225A PANEL. NEW SRVICE UNDER SEPARATE PERMIT.SYSTEM SIZE IS 7.20KW DC & 7.60KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17572	16041-10000-32924	3831 N DIAMANTE PL	91436	5	162B137   386	2293002014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM			PC Info Complete	09/21/2016 12:00:00 AM	ADDRESS	34.13961	-118.49548	PV1 SFD THIS IS GROUND MOUNTED SOLAR. SYSTEM IS USING MICROINVERTERS. TOTAL OF 34 MODULES. INTERCONNECTED TO MAIN SERVICE PANEL. TOTAL SIZE IS 7.3KW AC	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17573	18041-20000-10870	5757 W WILSHIRE BLVD Suite 504	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 only. Project site is an existing suite in a high-rise commercial building. Project scope is a tenant improvement. Total lighting area = 4,222 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17574	17041-20000-46238	8501 N SUNLAND BLVD	91352	6	192B177   196	2408014027	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.22481	-118.36592	ti to an existing commercial space.  adding new lighting new controls to new panel.  plan check for indoor energy only.this is plan check only.permit fees paid under application number 16041-10000-12529	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17575	16041-20001-23386	9501 S AVIATION BLVD	90045	11	093B173   221	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	33.95061	-118.37764	[[ 10/20/16 CHANGES TO APPROVED SET. ADDITION OF NEW 100AMP SAFETY SWITCH AND METER MAIN TO UPDATE PLANS PER DWP/INSPECTION REQUIREMENT. CHANGES ARE CLOUDED]]]PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 24KW INTERCONNECTED WITH MSP.(117) SOLARFUN MODULES(3) SMA 8000 INVERTERS$0 permit fee is due to State Senate Bill SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17576	17041-10000-29699	5326 E YORK BLVD	90042	14	156A227   462	5478004023	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.1198	-118.19937	PC FOR 7/11 TENANT. PC FOR POWER AND ENERGY. FIRST TIME TENANT TO NEW LANDLORD SERVICE. (CODE ENFORCEMENT BACK 2014 CASE NUMBER 186410 FOR 30 DAY TIME LIMIT PERMIT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17577	17041-20000-28031	6200 N CANOGA AVE #202	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.1833	-118.59719	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO EXIST. OFFICE SPACE (1838 SF) ON SUITE 202.building permit # 17016-20000-17958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17578	17041-10000-44241	23347 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.15761	-118.63417	TI IN AN EXISTING COMMERCIAL BUILDING (BANK OF AMERICA).PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17579	13041-10000-10037	6179 N JARED CT	91367	3	177B085   111	2032011019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	06/17/2013 12:00:00 AM	ADDRESS	34.18359	-118.65785	PV1 SINGLE FAMILY DWELLING; 1-STORY HOUSE. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 11.52 kW. TOTAL MODULES: 48.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17580	14041-10000-25443	16124 W WYANDOTTE ST	91406	6	186B141   772	2205027022	MR1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.20284	-118.48453	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 2548 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17581	11041-10000-24381	1008 E LAKE ST BLDG 5-2	90291	11	111B145   574	4243003040	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/28/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.00126	-118.46039	Lincoln Place Apartment Building Project.  New 2-story apt. building with 9 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17582	14041-10000-35047	7630 W SUNSET BLVD	90046	4	147B177  1011	5550029028	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.09786	-118.35599	T24, INTERIOR REMODELING FOR FEDEX OFFICE. TOTAL  AREA 3822 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17583	13041-10001-33105	8144 N WILLIS AVE	91402	6	192B149   574	2210014018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/08/2013 12:00:00 AM	ADDRESS	34.21917	-118.45516	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR SYSTEM. 1 STORY. SYSTEM SIZE: 3.25 KW DC. TRANSFORMERLESS UNGROUNDED SYSTEM.(13) TRINA SOLAR TSM250P(13) SOLAR EDGE POWER OPT 250(1) SOLAR EDGE SE3000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17584	15041-10000-36380	624 S PACIFIC AVE	90731	15	015B197   463	7455005026	[Q]C2-1XL-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Expired	11/28/2017 12:00:00 AM	ADDRESS	33.73824	-118.28773	Remove HiD ligh fixtures and replace with new LED fixtures. SQ ft = 4680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17585	16041-10000-20354	11845 W OLYMPIC BLVD 910 W	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.03291	-118.45177	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE ON SUITE 910W. TOTAL AFFECTED AREA IS 3215 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17586	15041-20002-44041	1254 W YOSEMITE DR	90041	14	160-5A229 292	5480020009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.13323	-118.19322	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17587	16041-10007-35308	19535 W NORDHOFF ST BUILD. B	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	PIN	34.2363795	-118.55851216	PLANCHECK ONLY FOR CHANGES TO APPROVED SET UNDER DELTA 19 & 21. SCOPE INCLUDES: ADDED CIRCUITS FOR HEAD SMOKE DOORS, REVISE FLOOR PLANS TO SHOW NEW HEAD SMOKE DOORS CKTS, RELOCATE EV CHARGING STATION AND CHANGES TO RESIDENTIAL UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17588	18041-10000-33437	2049 CENTURY PARK EAST S610	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	PIN	34.05864553	-118.41292403	PLAN CHECK FOR TITLE 24 ONLY - INTERIOR OFFICE TI  6393 SQ FT no change of use	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17589	13041-10000-10286	3857 S SYCAMORE AVE	90008	10	117B177   214	5029003013	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2013 12:00:00 AM			PC Approved	04/22/2013 12:00:00 AM	ADDRESS	34.01659	-118.35711	PV1.  Install roof-mounted solar array, interconnect with main panel.  4.165 KW DC system size.  {17 modules: TSM-245 PA05} {Transformerless inverter: PVI-5000-OUTD-US}Plan check only for changes to solar installation (inverter model changed to transformless type) that was originally eligible for express permit under 13041-20000-09275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17590	18041-10000-20344	6505 S ESPLANADE #5	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			Reviewed by Supervisor	06/13/2018 12:00:00 AM	ADDRESS	33.96159	-118.45071	5 OF 5******PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT BUILDING. CONISIT OF 12 MODULES(#SC325) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 3.9KWdc.SCOPE INCLUDES NEW LOAD CENTER (125A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17591	11041-20000-00772	7800 N WOODLEY AVE	91406	6	189B141   290	2206009901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM			PC Approved	09/15/2011 12:00:00 AM	ADDRESS	34.21161	-118.48344	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17592	14041-20000-22853	18322 W BLYTHE ST	91335	12	189B125   467	2102015049	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.21463	-118.53247	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8KW AC USING THE ENPHASE M215. 46 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17593	19041-10000-16839	1305 W INGRAHAM ST	90017	1	130-5A207  25	5143014004	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.05327	-118.2673	UPGRADE SERVICE ( 1200A 120/240V 3PH 4W) TO APARTMENT BUILDING AND INSTALLING 76 HEAT PUMPS ON THE ROOF.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17594	16041-20000-15883	4940 N VAN NUYS BLVD 2ND FLR	91403	4	169-5A151  37	2248007255	C1.5-1VL-RIO, R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Issued	06/03/2016 12:00:00 AM	ADDRESS	34.16043	-118.44849	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4420.  SCOPE OF WORK 2ND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17595	18041-10001-22066	4466 N BECK AVE	91602	2	165B169    62	2365008020	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2018 12:00:00 AM			PC Approved	08/03/2018 12:00:00 AM	ADDRESS	34.15223	-118.38322	NEW 12.6 (DC) KW, 11.2 (AC) KW PV SYSTEM WITH 35 PV MODULES, 35 MICRO-INVERTERS, 2 TESLA BATTERIES AND SERVICE UPGRADE TO 400 AMPS ON A SINGLE FA,ILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17596	16041-10000-40556	338 N PATTON ST	90026	1	135A209    20	5160009003	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			11/16/2016 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	05/03/2021 12:00:00 AM	ADDRESS	34.06615	-118.25849	Plan check for power and energy New appartment Builing 44 units 5 story Service size: 1600A. Total area: 42,026 sq ft located in a Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17597	19041-20000-48908	6345 N BALBOA BLVD BLDG 4	91406	6	180B133   572	2230024***	[Q]C4-1VL-RIO	South Valley	Reseda - West Van Nuys	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.1861	-118.50323	T24 ENERGY ONLY PLAN CHECK FOR LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 1749 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17598	17041-20000-22482	8517 N GEYSER AVE	91324	12	192B121   248	2785011044	R1-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.22509	-118.54274	PV1.  Install 5 kW ungrounded solar PV system, roof-mounted on SFD.  (22) 255W modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17599	18041-10000-18744	20215 W SATICOY ST	91306	3	186B113   166	2114004017	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.20847	-118.57375	INSTALL A NEW FIRE ALARM SYSTEM IN AN ADULT DAY CARE BUILDING WITH 97 DEVICES AND TWO PANELS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17600	19041-10000-31609	5200 N LANKERSHIM BLVD 140	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.16511	-118.37448	ENERGY PC FOR CHANGE OF USE FROM TRADE SCHOOL TO RESTAURANT W/TENANT IMPROVEMENT. AREA SCOPE 1,137SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17601	17041-20000-40184	16238 W RAYMER ST	91406	6	189B137    19	2205029037	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.21771	-118.48681	0$ permit fees due to senate bill 1222pv2install roof mounted pv system sized 90kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17602	12041-10000-08956	1800 S CENTURY PARK EAST #111	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.06244	-118.41523	T.I. to an existing high-rise office building.  Load is 54 amps and occupancy load is less than 99, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17603	15041-10000-31364	11533 W DONA PEPITA PL	91604	2	156B169   190	2381024012	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM			Reviewed by Supervisor	09/28/2015 12:00:00 AM	ADDRESS	34.12634	-118.38613	PV1, INSTALL NEW 7.6 KWDC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(36) MODULES: SOLAR WORLD PLUS 281 (1) INVERTER: FRONIUS IG PLUS A7.5-1 UNI	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17604	18041-20001-04909	501 N SOTO ST	90033	14	129A225   101	5175009029	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	34.04865	-118.20687	Expedited per applicant request.Plan check for a PV2 roof-mounted Pv system. System size is  11.4 kWac/15.0 kWdc and consists of (1) inverter and (50) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17605	14041-10000-29314	6512 W HOLLYWOOD BLVD	90028	13	148-5A187 181	5547016003	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM			PC Approved	10/22/2014 12:00:00 AM	ADDRESS	34.10143	-118.33159	Title 24 plan check only.  Installation of 4 LED recessed ceiling lights & sconce above sink, motion sensor switch in new mens restroom.Original permit # 14041-100000-26861	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17606	13041-20000-01619	527 S MOLINO ST	90013	14	126A217   220	5163021038	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			01/23/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.04096	-118.23399	Plan check for fire alarm for 68 unit apartment. METHANE ZONE. Filed simultaneously with associated electrical permit. Related electrical permit is under 13041-20000-01623.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17607	17041-20001-25883	953 N SYCAMORE AVE	90038	4	144B181   641	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.08865	-118.34299	11-01-2018 Changes to an permtted set of plan. Changes include reduction of initiation device. All changes has been clouded. Plan check only, permit covered under master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17608	12041-10000-23550	5112 W HOLLYWOOD BLVD 105-107	90027	13	148-5A195 108	5544013069	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.10159	-118.30108	Combining space from an adjacent hair salon (#105) and adding to an existing restaurant (#106-107).  Load is less than 200 Amps, and occupancy load is 88.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17609	10041-10000-24598	19899 S PACIFIC GATEWAY DR	90502	15	057B197    50	7351034057	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	12/21/2011 12:00:00 AM	ADDRESS	33.85051	-118.29542	New PV system. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17610	18041-20000-06102	13245 W RIVERSIDE DR #400	91423	4	168B157   316	2358014027	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Issued	08/06/2018 12:00:00 AM	ADDRESS	34.15778	-118.42187	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17611	17041-10002-08121	17742 W RAYEN ST	91325	12	195B129   252	2768012007	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM			PC Approved	05/22/2017 12:00:00 AM	ADDRESS	34.23185	-118.52159	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE TO STRING WIRING DIAGRAM AND METER DISCONNECT ORDER. CHANGES CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17612	17041-10000-10827	3325 W WILSHIRE BLVD 1300	90010	10	135B197  1123	5502027010	C4-2, R5-2, R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	34.06195	-118.2949	PC for T24 only. TI for office space in 13th floor of building. PC for new lights and receptacles .Total area 4553 sqft.Load under 400 A.Building app 16016-10000-29660	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17613	11041-10000-20202	18585 W VENTURA BLVD	91356	3	174B121   623	2160007032	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.16994	-118.5384	T.I. to an existing bank.  PLAN CHECK ONLY for Energy with Emergency Lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17614	14041-10000-24589	22643 W VENTURA BLVD	91367	3	171B097   166	2040028010	C1.5-1VLD, C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Issued	09/09/2014 12:00:00 AM	PIN	34.16770476	-118.62042219	Title 24 plan check only.  Total area = 1,280 sq. ft.T.I. to existing domino's pizza.Partial Permit fees already under 14041-10000-24582 (20 branch circuits).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17615	10041-10000-11861	500 W WORLD WAY MCP-07	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-07. ( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17616	14041-10000-14943	2576 N CORDELIA ROAD	90049	11	141B133    80	4492024005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.08398	-118.50641	PV1, INSTALL 10.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17617	19041-10000-11155	7530 N SAN FERNANDO ROAD	91352	2	186B181   181	2405008035	[Q]CM-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1021.05	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.20869	-118.35273	T-24 PLAN CHECK FOR TENANT IMPROVEMENT IN A FACTORY FACILITY. SCOPE INCLUDES NEW 100A PANEL, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 3056 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17618	18041-10001-47589	6233 N VARIEL AVE	91367	3	177B105    18	2149001027	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Apartment			03/05/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.18397	-118.59309	Plan resubmittal due to design change, there has been significant revision to single line diagram, loaschedule and calculation.  This is plan check only, permit is issued under master #18041-10000-47589<<New 8 story, 336 Unit,  assisted living facility over 1 level subterranean parking.Plan check for power & energy. Building Permit: 18010-10000-04241(Fee Estimate Only - Verify Fees during PC)>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17619	16041-20001-41230	17963 W INGOMAR ST	91335	12	189B129   950	2101025007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.21252	-118.52501	01/31/2017 Changes to an approved PV1 roof-mounted PV system. A new standard plan has been created with the updated information.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17620	13041-10000-34133	1804 E VERNON AVE BLDG D	90058	9	112-5A213  62	5106005009	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.00379	-118.24089	PLAN CHECK FOR EMERGENCY LIGHTING AND EXIT SIGNS ONLY PER INSPECTORS REQUEST. 4 OF 5 BUILDINGS. BUILDING D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17621	12041-10000-00683	3813 W RONDA VISTA PL	90027	4	150B201  1201	5433009002	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2012 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.10477	-118.27596	New 7.52 kw photovoltaic, rooftop, system for an existing single family residence.  Two inverters and 32 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17622	16041-20001-16355	14708 W VENTURA BLVD 2nd Floor	91403	4	166-5A149  67	2276002020	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM			PC Approved	02/08/2017 12:00:00 AM	ADDRESS	34.15154	-118.45347	[[[[2/8/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES. PROVIDING OCCUPANCY SENSORS IN ALL AREAS TO MEET SHUTOFF REQUIREMENTS]]]]Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement/change of use from office to hair salon. Total lighting area = 6,950 sq. ft.Note: Building application has been created under 16016-30000-10197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17623	15041-10000-03679	10940 W WILSHIRE BLVD 11th floor	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.05822	-118.4452	Plan check for Title 24 only. Project site is the 11th floor of a high-rise building. Project scope is a tenant improvement. Total lighting area = 10,256 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17624	18041-30000-40585	140 S ROBERTSON BLVD	90048	5	138B169   454	4334005007	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Info Complete	10/23/2018 12:00:00 AM	ADDRESS	34.0743	-118.38359	PLAN CHECK FOR T24 ONLY, INTERIOR TI TO (E) RETAIL . TOTAL AREA 1,180 SQ.FT(B# 18016-10000-29675)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17625	11041-10000-18218	12352 N WOODLEY AVE	91344	12	219B137   107	2605006001	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.29494	-118.49238	NEW 14 KW ROOFTOP PHOTOVOLTAIC SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17626	16041-10002-26870	23397 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.15981	-118.6342	Changes to an approved set of plans. All changes are made under delta 6. Changes include relocating/removing emergency lights, adding bug eyes, and revising emergency photometrics.Note: Permit is paid under PCIS#16041-10001-26870	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17627	14041-10000-14867	12698 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	33.97714	-118.41552	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17628	19041-10000-41725	657 W 18TH ST	90015	9	124-5A205  73	5126001015	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Info Complete	10/15/2019 12:00:00 AM	ADDRESS	34.03634	-118.27308	POWER PLAN CHECK TO REPLACE (2) EXISTIG 100a AND 200A SERIVICES WITH NEW 600A SERVICE. SCOPE INCLUDES NEW EQUIPMENT AND 3 A/C UNITS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17629	15041-10000-14364	3321 W 63RD ST	90043	8	105B185   799	4006003035	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	33.98304	-118.33025	PV1 4.2KW AC roof mounted system; scope includes (11) SunPower SPR-327 modules and (1) Power One PVI-4.2-TL inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17630	15041-20000-11371	14640 W VICTORY BLVD	91411	6	180B149   895	2241003007	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.18644	-118.45224	Plan check for a new fire alarm system within an existing commercial space. Fire alarm consists of (1) FACP, (1) RPS, and (65) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17631	09041-20001-10151	12921 W MAGNOLIA BLVD	91423	4	171B161   452	2345017031	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			01/13/2010 12:00:00 AM			PC Approved	01/27/2010 12:00:00 AM	ADDRESS	34.16503	-118.41465	This is revision to previously approved plan T.I in Ralphs Grocery store.  The changes are clouded on the plan. No permit required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17632	14041-10002-12437	127 S LA BREA AVE	90036	5	138B181   989	5513019011	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.07273	-118.34423	Changes to an approved set regard to new  K2 fixture under delta 3 only[[9/8/14  CHANGES TO APPROVED SET OF PLANS. PLANCHECK ONLY. DELTA 2 CHANGES ONLY. CHANGES TO LIGHTING ONLY]]]TI TO EXISTING RESTAURANT. PLAN CHECK IS FOR POWER AND ENERGY, OCCUPANT LOAD EXCEEDS 100. EXISTING SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17633	16041-10000-01920	705 N ALFRED ST	90069	5	141B173   424	5528001055	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM			PC Approved	01/19/2016 12:00:00 AM	ADDRESS	34.08391	-118.3755	T-24, TENANT IMPROVEMENT AND CHANGE OF USE FROM RETAIL TO COFFEE SHOP. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17634	15041-10000-00791	19021 W MIRANDA ST	91356	3	174B121   144	2156012023	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.1753	-118.54832	Plan check for a PV1 roof-mounted PV system. System size is 13.2 kWac and consists of (2) inverter and (64) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17635	16041-10000-20664	5606 S FORTUNA ST	90011	9	108B213   402	5105015020	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	33.99184	-118.24543	PV1 INSTALL NEW 2.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(10) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17636	13041-10000-23145	11748 N ANDREW AVE	91344	12	213B137    19	2605014021	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.2845	-118.48874	PV1 8KWDC 240V(-)XFMR INV. 1STORY. STD. ROOFMOUNT.[( 1) INV:  FRONIUS IG PLUS V10][( 33) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17637	13041-10000-32554	640 S MAIN ST	90014	14	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			Reviewed by Supervisor	02/27/2014 12:00:00 AM	ADDRESS	34.04429	-118.2507	PLAN CHECK FOR POWER. 600 UNIT HOTEL. 15 STORIES. WORK IS ON EVERY FLOOR. NEW FEEDERS FOR EXISTING SWITCHBOARDS AND PANELS. NEW 2500 AMP SERVICE AND SWITCHBOARD WITH NEW PANELS AND TRANSFORMERS. [[[[[[ FEES CALCUALTED TO BE 9168.51, 80 - 277 CKTS ADDED TO COMPENSATE FOR APPLICANTS PRE CUT CHECK]]]]CECIL hotel. Not methane	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17638	17041-10000-44216	7257 N TOPANGA CANYON BLVD	91303	3	186B101   932	2023007025	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.20265	-118.60618	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17639	18041-30000-48862	300 S GRAND AVE Suite 2500	90071	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.05283	-118.25116	Plan check for Title 24 only. Project site is suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,235 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17640	14041-20000-15796	18125 W ABBEY ROAD	91335	3	177B125   108	2124017089	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.18489	-118.52823	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17641	15041-20000-29780	7611 W BEVERLY BLVD	90036	5	138B177   415	5526042014	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.07629	-118.35578	Plan check for energy only. Change of use from retail to massage parlor. New lighting (incl. emergency). 2,101sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17642	11041-20000-16197	1258 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/02/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29334	New 3.23 KW PV System for Apartment Bldg #1258	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17643	18041-10002-22758	653 1/2 E MILWOOD AVE	90291	11	108B145   951	4241005024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	PIN	33.99226654	-118.46398708	SUPPLEMENTAL FOR CHANGES TO APPROVED PLAN, REMOVAL OF (1) AC DISCONNECT, MOVING (1) INVERTER, AND CHANGE FROM SC325 TO SC320 SOLAR MODULES AND ADDING (1) MODULE TO CHANGE FROM 5.2 DC KW PV ARRAY TO 5.44 DC KW PV ARRAY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17644	13041-10001-24701	6132 S HARCOURT AVE	90043	8	105B181   918	4004027016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	33.98362	-118.34056	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17645	13041-10000-02111	929 S BROADWAY	90015	14	127-5A209 256	5139003005	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.04174	-118.25687	New fire alarm system for high-rise mixed occupancy.  13 stories.  82000 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17646	16041-10000-29429	1746 N CHEROKEE AVE	90028	13	148-5A185  13	5547004012	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			08/18/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.10294	-118.33462	PV, install a 58.23 kw dc roof-mounted solar array on a apartment building. (191) modules:q. pro L-G2 305-315(3) inverters: sma sb10000tl-us 10 kw and (2) inverters: symo  Fronius 10.0-3**Note: Fees are $0 due to senate bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17647	19041-20001-01951	12217 W EMELITA ST	91607	2	174B165   118	2340009013	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.1764	-118.39938	Expedited plan check fee.PV1.  Install 14.4 kW DC / 12.2 kW AC roof mounted grid tied PV system. (40) modules with 11.4 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17648	19041-10000-10647	2521 S WEST VIEW ST	90016	10	123B181   886	5049008051	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.03311	-118.34826	Remove HID fixtures and replace with new LED fixtures (Outdoor only), - T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17649	11041-20000-11514	12950 W RAYMER ST	91605	2	186B161   523	2327016028	M2-1VL	South Valley	North Hollywood - Valley Village			1220.00	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM	06/09/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.20492	-118.41595	PLAN CHECK FOR NEW 600A SERVICE, SWITCHBOARD, 200A SUBPANEL. CONSOLIDATE EXISTING 400A AND 200A SERVICE. ALL LOAD EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17650	19041-10000-14578	3300 S CANFIELD AVE	90034	5	123B165  1004	4311025051	R3-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	01/25/2021 12:00:00 AM	ADDRESS	34.03099	-118.39465	NEW FA SYSTEM IN A 3 APPARTMENT COMPLEX. SCOPE INCLUDES 1 FIRE ALARM PANEL, 1 ANNUNCIATOR AND 35 DEVICES. FA PANEL WITH 2*12V AT 12AH EACH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17651	14041-20000-24883	7014 S HOOVER ST UNIT 3	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 3.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17652	11041-20000-04212	10880 W WILSHIRE BLVD 4th Floor	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	05/09/2011 12:00:00 AM		Permit Finaled	07/05/2011 12:00:00 AM	ADDRESS	34.05885	-118.44283	T.I. to existing high rise building.  Install general/emergency lighting partial of 4th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17653	16041-20000-33331	777 S FIGUEROA ST 39th flr	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.04828	-118.26116	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only.  scope to be in the 39th floor only.  total square footage 1078	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17654	19041-10000-14075	11201 S AVIATION BLVD	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	33.93281	-118.37945	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17655	18041-20003-04018	926 N NORDICA DR	90065	1	153A221   316	5475017025	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.11284	-118.22039	11/2/2018changes to correct word description.PV1.  Install 3.9 kW PV system.  (12) modules with 3.8 kW rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17656	14041-20000-06098	22834 W OSTRONIC DR	91367	3	171B097   225	2042015005	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.16737	-118.62462	PV1 ROOFTOP TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17657	15041-10002-29688	7515 S CENTRAL AVE	90001	9	102B209   390	6023013004	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	33.97144	-118.25659	Supplemental PC and Permit for T-24 per inspector request (Field Correction). Total area: 1,038 sq.ftAdditional permits under this scope of work are: 15041-70000-29688, 15041-70001-29688	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17658	17041-10001-28796	10334 N ORO VISTA AVE	91040	7	204B189   392	2560013007	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.25711	-118.31562	EXPDITE PER APPLICANT REQUEST *********************************************************************PC FOR ROOF MOUNTED PV ON SLD SYSTEM SIZE 3.0KWAC USING CENTRAL INVERTER.INCLUDING 11 MODULES AND LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17659	13041-10000-30631	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	Building 1 of 5: Administration Bldg and Clubhouse renovation (rock garden electrical room included under club house).  Install new electrical panels, new convenience receptacles and new indoor and outdoor lighting.  Fire alarm plans included.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17660	18041-20000-23619	410 E 68TH ST	90003	9	102B205   260	6011011018	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	03/15/2019 12:00:00 AM	ADDRESS	33.97779	-118.26708	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (25) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17661	16041-20000-29553	5757 N AGNES AVE	91607	2	174B165   282	2340027041	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.1753	-118.39561	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (25) modules. Standard plan is being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17662	10041-20000-05252	12744 N SAN FERNANDO ROAD BLDG 4	91342	7	222B145   396	2506003010	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.30155	-118.46112	MULTIPLE REVISIONS TO PCIS# 09041-20000-04313 (new industrial bldg).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17663	15041-10001-28404	1420 N DAVIES DR	90210	5	147B153   182	4357009017	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.09788	-118.43449	PV1, INSTALL NEW 41.6 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(160) MODULES: KYOCERA KU2606XPA(3) INVERTERS: FRONIUS SYRNO 12.0-3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17664	17041-10002-34944	4300 W SUNSET BLVD	90029	13	145-5A201  87	5429006011	C2-1D	Central	Hollywood	Silver Lake		1913.02	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Closed	01/09/2018 12:00:00 AM	ADDRESS	34.09459	-118.28304	PC FOR CHANGES TO APPROVED SET *******************************FOR TITLE 24 ENERGY ONLY!!******************************* SCOPE INCLUDES CHANGES TO LIGHTING FIXTURE COUNT DUE TO ADDITION OF CELING HEATERS. SOME ADDITINONAL CIRCUITS AND EQUIPMENT.  ALL CHANGES MARKED UNDER DELTA 3 AND 4. PC FOR RETAIL TI, CONVERT IRREGULAR-SHAPED PORTION OF (E) STORAGE BUILDING (400 SF) TO RETAIL. SCOPE OF WORK INCLUDES NEW PANEL,  CIRCUITS AND EQUIPMENT. TOTAL AFFECTED 400 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17665	18041-20000-35973	16830 W VENTURA BLVD 4th & 6th-Floors	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check for Title 24 only. Project site is the 4th and 6th floor corridors of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 814sq. ft.Note: Building permit has been issued under 18016-20000-25599	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17666	19041-10000-07864	20929 W VENTURA BLVD UNIT 11	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTING AND EXIT SIGN TO EXISITNG RETAIL SPACE FOR FUTURE TENANTPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17667	16041-20002-43185	4147 S SUNNYSIDE AVE	90066	11	108B153  1049	4230011017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	33.99028	-118.43885	01/26/2017 Changes to an approved set of plans. Changes have been made to the MSP and the MCB.*****Previous Work Description*****$0 fee due to senate bill 1222 from 2012PC FOR PV SYSTEM ROOF MOUNTED, TOTAL SYSTEM SIZE 13KW AC USING 2 CENTRAL INVERTERS AND TOTAL OF 49 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17668	14041-20000-36053	18537 W STRATHERN ST	91335	12	189B125   271	2103009***	(Q)RD6-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.21576	-118.53751	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A subpanel, fed from a 200A MSP.System size: 3.6kW. Ungrounded system.17  255kW pv modules across two strings (8+9).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17669	13041-20000-20374	2216 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Approved	07/31/2013 12:00:00 AM	ADDRESS	34.03778	-118.44068	Plan check for energy and emergency lighting. Low-rise commercial. European Wax Center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17670	16041-20001-45841	8400 N BALBOA BLVD #115	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM			PC Approved	04/17/2018 12:00:00 AM	ADDRESS	34.22376	-118.50243	04-17-2018 Changes to an approved set of plan. Changes include revise feeder size to 2 sets of 3/0 conductor. Changes has been clouded as delta 10. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17671	18041-30000-37026	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Info Complete	10/10/2018 12:00:00 AM	ADDRESS	34.08157	-118.2915	PC FOR TITLE 24 FOR TI  OF A FIRST FLOOR OPEN STUDENT SPACE INTO OFFICES.SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND RELOCATING FIXTURES. TOTAL AFFECTED AREA  1095 S.F B# 18016-30000-31405	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17672	17041-20001-41392	8120 N JASON AVE	91304	12	189B093    48	2020021014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.21782	-118.63511	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (w/roof-mounted array) and AC coupled battery backup system for SFD.(1) 3kW ungrounded pv inverter. (9) 300W pv modules. (9) 400W power optimizers.(2) 5kW Tesla Powerwall 2s.Existing 11kW pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17673	15041-20000-10971	1355 N GARDNER ST	90046	4	147B177  1280	5550024015	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			04/15/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.09593	-118.35301	Installation of new roof mounted solar PV array.  Total system size = 14 kWac.  Single inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17674	11041-10000-19177	8600 S CENTRAL AVE	90002	9	097-5A209 255	6043001027	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	33.95988	-118.25616	Ti in an existing 7-11 store. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17675	17041-10000-15813	1154 S ROBERTSON BLVD	90035	5	132B169   808	4332015040	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.05546	-118.38352	Title 24 plan check.  T.I. to existing office building.  Existing subpanel to feed new lighting and receptacles.  Total area = 1,230 sq. ft.       Building permit #17016-10000-12298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17676	17041-10002-03657	18207 W SHEFFIELD LANE	91326	12	213B125    19	2870019019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.28386	-118.53093	Supplemental for changes to approved set. Reducing the NUMBER OF MOUDULES  from 38 to 29  and changing microinverter model to IQ6, changing module type and keeping existing 200A main breaker.REVISED SYSTEM SIZE 6.96KWAC AND TOTAL MODULE SYSTEM SIZE IS 8.7KWDC. Inspection fees to cover change of description.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17677	15041-10000-37690	7337 N VARNA AVE	91605	2	186B157   440	2328027001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.20396	-118.42484	T24 only. remove HID light fixtures and replace with new LED fixtures. Total area 1920 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17678	18041-10000-26391	9045 W ORIOLE WAY	90069	4	147B169   770	5560004013	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	Yes	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	12/15/2018 12:00:00 AM	ADDRESS	34.09694	-118.38765	"""0$ permit fees due to senate bill 1222, AB 1414""ENERGY STORAGE SYSTEM (6) LG CHEM 10H  + SYSTEM SIZE: 28.86KW DC , PV1. ROOFMOUNTED SOLAR SYSTEM.  (78) SILFAB SLG370M , (3) STOREDGE 7600"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17679	18041-20000-30695	5999 W CENTER DR	90045	11	102B169   959	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	33.9761	-118.38876	Plan check for Title 24 Energy only T.I. in corridor, restroom and engineering shop new lighting. 1136 sq ft. B# 18016-30000-21927	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17680	13041-10000-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			12/30/2013 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.10155	-118.31097	DUE TO VALUE ENGINEERING TOTAL # OF CKTS REDUCED BY1759 CKTS , PALN CHECKED. WAS DONE ON APPLICATION # 13041-10001-36165 FOR VOLTAGE DROP CALS AND VALUE ENGINEERING.     M.ZANDI    9-16-2015    2-13-15  m.zandi..   addition of 50 branch circuits for basement circuitry  and title 24  percustomers information.)))))((   ORIGINAL SUBMITAL  ))New mixed-use 8-story, 280 unit apartment/retail over parking garage:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17681	14041-10000-17231	1150 S OLIVE ST 30th FLOOR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.03962	-118.26181	permit to be pulled at EPC counter only. Plan check for energy only. TI (E) MULTIPURPOSE ROOM PER APPLICANT. LESS THAN 400A. emergency lights in high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17682	16041-20000-15646	6144 W VENICE BLVD	90034	10	123B173   350	5065012070	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.03508	-118.37759	PLANCHECK FOR T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17683	18041-10000-28248	6634 N VALJEAN AVE	91406	6	180B141   284	2233029017	M1-1-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.19126	-118.48565	REPLACE INDOOR/OUTDOOR FLUORESENT TROFFERS WITH NEW LED RETROFIT KITS.  REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17684	19041-10000-46471	451 W ELBERON AVE	90731	15	021B197   864	7448024010	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	ADDRESS	33.75	-118.28842	NEW ROOF MOUNTED 4.72KW PV SYSTEM WITH 16 @ (295W) PV PANELS  AND 16@ ENPHASE MICRO INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17685	19041-20000-50099	652 W SOLANO AVE	90012	1	139-5A217  77	5415029008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural North	YES	2060.10	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.07655	-118.23324	PV1 NEW PV AND ESS, PV SYSTEM SIZE IS 3.63 KW DC/3.34 KW AC CEC. ESS SIZe IS 13.5 KWH. SCOPE OF WORK IS (11) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, A SUB PANEL, AND A 5.8 Kva BATTERY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17686	15041-10001-28019	9220 N WINNETKA AVE	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM			PC Approved	04/14/2017 12:00:00 AM	ADDRESS	34.23795	-118.57084	re-checking plans with new revisions. This application is plan check only, some mechanical changes and 1 new medium voltage service, plan checker to verify all fees and adjust final fee on master permit.this application is for plan check time only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17687	12041-10000-28974	631 S MANSFIELD AVE	90036	4	135B181   704	5507021006	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2012 12:00:00 AM	12/31/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.0641	-118.34089	ROOF MOUNTED PV1 SOLAR INSTALLATION. 3 STRINGS AND 2 INVERTERS.  SYSTEM SIZE (DC) IS 8.70 KW. POSITIVELY GROUNDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17688	10041-20001-23778	7800 W WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM			PC Approved	04/12/2011 12:00:00 AM	PIN	33.93790872	-118.42837934	move staker location plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17689	15041-20000-15639	100 S SANTA FE AVE Suite R	90012	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.04798	-118.23239	"Plan check for energy only. Change of use of tenant space from retail to take out ice cream store (""Van Leeuwen Artisan Ice Cream""). New lighting incl. emergency. 425sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17690	16041-20000-10769	1800 N HIGHLAND AVE	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	34.10436	-118.33763	PLANCHECK FOR T24 ENERGY.  OFFICE TI. 7TH FLOOR. 549 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17691	17041-30001-43362	12103 W VENTURA PL	91604	2	165B165  1211	2368002014	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.14501	-118.39527	01-09-2018 Changes to approved set of plan. Changes include replace lighting control system. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17692	10041-10000-16254	10720 S WILMINGTON AVE	90059	15	088-5A215  57	6065036001	C2-1VL	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Public Safety Only			08/18/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	33.93844	-118.2388	NEW FIRE WARNING SYSTEM AT WILMINGTON STREET SCHOOL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17693	12041-10000-06289	10587 W PICO BLVD	90064	5	126B157   349	4320013016	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.04375	-118.42184	RETAIL PHARMACY  AND POSTAL SERVICE  PLAN CHECK ONLY FOR T24 ENERGY WITH EMERGENCY LIGHTING. PERMIT FOR NEW PANEL AND BRANCH CIRCUITS. LESS THAN 400A INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17694	19041-10000-48197	5780 W CENTINELA AVE	90045	11	102B169    69	4103005014	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	33.9762	-118.38093	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK IS ADDING 31 EV CHARGERS (LEVEL 2), CONNECTED TO AN EXISTING 800A SWITCHBOARD (120/208 3P,4W).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17695	12041-10000-04009	807 N LA CIENEGA BLVD UNITS  1-4	90069	5	141B173   195	4337002081	C4-1VL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	34.08546	-118.37673	SINGLE STORY COMMERCIAL BUILDING WITH ROOF PARKING. SUBDIVIDED INTO 4 TENANT SPACES. SHELL ONLY. NEW 800A SERVICE UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17696	19041-10000-15355	6316 N TOPANGA CANYON BLVD 1120-1125	91367	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Issued	05/01/2019 12:00:00 AM	ADDRESS	34.18578	-118.60514	Energy plan check for an amusement enterprise located in the mall. Scope includes new lighting and equipment with a total area of 4940-SQ FTBld# 19016-10000-00916	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17697	16041-10000-26788	8323 N BALBOA BLVD	91325	12	192B133   235	2690023190	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.22177	-118.50286	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES A NEW 600 AMP SERVICE, FEEDING (E) LOAD AND PROVISIONS FOR 2 NEW PANELS. (E) BREAKERS ON (E) PANELS SHALL MATCH NEW SERIES RATED COMBINATION.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17698	10041-20000-15146	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	06/29/2011 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	Plan check power and energy for new mixed use building with 4000A service. Modification to seperate fire alarm system submitted. Methane buffer zone requirements not applicable per site methane report.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17699	12041-10000-22597	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			PC Approved	09/21/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI IN AN EXISTING OFFICE. EPC IS FOR T24. (SUITE# 1700)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17700	16041-10000-34956	21900 W VANOWEN ST 2ND FLOOR	91303	3	180B105    76	2139004047	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Issued	10/21/2016 12:00:00 AM	ADDRESS	34.19217	-118.60389	TI FOR MAC COSMETICS INSIDE (E) MACY'S STORE. NEW DISPLAY CASES. PC FOR ENERGY ONLY T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17701	18041-10000-46000	6543 N TAMPA AVE	91335	3	180B117   586	2131009018	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Issued	12/04/2018 12:00:00 AM	ADDRESS	34.18959	-118.55376	PV2. NEW ROOFTOP SOLAR SYSTEM WITH SIZE OF 3.965KWPDC CONSIST OF 13 MODULES USING P320 OPTIMIZERS CONSISTS OF (1) INVERTER SE3800H-USRGM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17702	17041-10000-23254	2610 S LA SALLE AVE	90018	8	123B193   624	5053020034	C1-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.03221	-118.30521	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17703	14041-20000-35132	7463 N VARNA AVE	91605	2	186B157   249	2328027020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	34.20651	-118.42487	Changes from previously approved plans (13041-20000-23548).  Change from Point of Interconnection at the service equipment to DWP Feed-In-Tariff only.  Note: Permit is under 13041-20000-23548.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17704	18041-20001-46084	18065 W VENTURA BLVD	91316	5	171B125   346	2162005067	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.16534	-118.5264	Title 24 plan check and supplemental permit for commercial TI electrical work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17705	20041-10000-18143	5001 W RODEO ROAD Gym & Pool	90018	10	120B181   948	5046013900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	02/28/2020 12:00:00 AM	PIN	34.02302534	-118.35149882	Void	N	N	Express Permit	06/10/2024 12:00:00 AM
17706	19041-10000-52623	20801 W VENTURA BLVD	91364	3	171B109    62	2166033054	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	01/27/2021 12:00:00 AM		Permit Finaled	02/18/2022 12:00:00 AM	ADDRESS	34.16663	-118.58589	T.I. FULL POWER AND ENERGY PC FOR AN EXISTING RETAIL SPACE. TOTAL AFFECTED AREA 103358sqft. SCOPE OF WORK INCLUDES ADDITION OF NEW PANELS AND EQUIPMENT.*****************************************************************************PER BUILDING APPLICATION# 19016-10000-40546:Remodel work, including exterior work, restrooms, fitting rooms, offices, cafe, etc. TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17707	16041-20002-36167	2441 S SEPULVEDA BLVD	90064	5	123B153   141	4256010006	(T)(Q)C2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	ADDRESS	34.0358	-118.43461	[[[3/27/18 CHANGES TO APPROVED SET. PLANCHECK ONLY.  DELTA 4 CHANGES ONLY. CHANGES IN THE SINGLE LINE DIAGRAM ]]]New 13-story (5 stories subterranean parking), 595-unit residential highrise with 1200A 4160V service.  Plan check for power and energy.  Building permit filed under 16010-10000-01422	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17708	16041-10001-02087	1025 S STANFORD AVE	90021	14	124-5A211 328	5132009019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			PC Info Complete	06/14/2017 12:00:00 AM	ADDRESS	34.03336	-118.24926	Changes to approved set.  All changes clouded.  Addition of 5 new retail spaces and 3 new elevators.  Upgrade transformer rating and add roll up gate motor to each tenant space.Master permit has been finaled by inspector, per inspector/applicants request this applications is now plan check only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17709	18041-10000-41205	451 S HARVARD BLVD	90020	10	135B193   622	5503011026	R4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.06563	-118.30429	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17710	14041-20000-02295	1017 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197    80	5037026017	P-1, [Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.01107	-118.29267	T24 FOR EXISTING COIN LAUNDRY. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17711	13041-10001-30822	519 W 76TH ST	90044	8	099B201    24	6020021028	[Q]R3-1	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/09/2014 12:00:00 AM	ADDRESS	33.97087	-118.28346	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 2 STORY. SYSTEM SIZE: 7.25 KW.(29) TRINA SOLAR # TSM-250PA05.18(29) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE6000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17712	19041-10000-27524	777 S FIGUEROA ST Ste. 4500	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Tenant improvement on 1,025 SF of total floor area.-NEW CONFERENCE ROOM	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17713	16041-20001-02285	8320 N OSO AVE	91306	3	192B113   519	2781019010	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.22081	-118.57527	Expedited per customer request.PV1. Install roof mounted PV sysem sized 20 kW. Interconnected with main service panel.(76) Solar World SW285 Modules(76) Solar Edge P300 Power Optimizers(2) Solar Edge SE10000 Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17714	13041-10000-28976	2525 S LONG BEACH AVE WEST	90011	9	117A213   307	5117002010	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	PIN	34.0137511	-118.24345516	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHTING FIXTURES AND REPLACE WITH FLUORESCENT FIXTURES.  9400 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17715	17041-10001-36590	2010 W 62ND ST	90047	8	105B189  1017	6001020015	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM			PC Approved	04/08/2019 12:00:00 AM	ADDRESS	33.98325	-118.31394	EXPEDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL BUILDING. ***SYSTEM IS A FEED AND TRAIFF***TOTAL SYSTMEN SIZE 29.4KWDC /64KWACINCLUDES 98 MODULES WITH 2 INVERTERSADDITIONAL SYSTEMS ARE INSTALLED ON SAME ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17716	13041-10000-10303	2130 E 1ST ST	90033	14	127-5A223 122	5183008901	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.04433	-118.21291	plan check under 13041-10000-10303. 5 new branch circuits and 10 units to existingREMODEL COMMUNITY ROOM AT CD 14 NEIGHBOR CITY HALLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17717	14041-20000-02604	11542 N ACALA AVE	91340	7	213B149   332	2613015033	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.27954	-118.45168	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17718	13041-20000-14769	13271 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW USING 15 MODULES ENPHASE M215 MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17719	13041-10000-33051	7516 W 83RD ST	90293	11	096B157   375	4114026014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	33.96122	-118.42888	Roof mounted PV system with 10.25 KW for single family dwelling.  Upgrade service main panel to 225A and install new 125A load center panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17720	18041-20000-30351	20555 W SHELLEY LANE	91326	12	213B109   791	2701094036	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.28193	-118.58194	Plan check for a PV1 roof-mounted PV system. System size is 5.8 kWac and consists of (18) AC PV modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17721	14041-10000-16968	6700 W SANTA MONICA BLVD	90038	4	144B185   780	5532026023	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.09055	-118.33652	PLAN CHECK FOR POWER AND LIGHTING.  TOTAL AREA = 11,375 SQ. FT.PROVIDE TRANSFORMERS + PANNELBOARDS, RUN REC, MECH AND LTG BRANCH CKT WIRING TO NEW EQUIPMENT.  PROVIDE EM LIGHTING INVERTER.FEE ESTIMATE ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17722	18041-10000-28695	11558 W DONA TERESA DR	91604	2	159B169   522	2381012002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	10/06/2018 12:00:00 AM	ADDRESS	34.13099	-118.38537	PLAN CHECK FOR A ROOF MOUNTED 11.4KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE 11400H-US) WITH 36 PANELS WITH P320 POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17723	15041-20002-22144	7514 N HASKELL AVE	91406	6	186B141   235	2206013012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			01/31/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.20712	-118.47477	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF MAIN DISTRIBUTION BOARD, ADDING PHYSICAL PROTECTION, AND RESIZING THE MAIN BREAKER ON MSA - CHANGES ARE CLOUDED UNDER DELTA 1 ON PLAN  5.31.2017 - Plan check for modification to approved set. Change panel MSB from 225A to 400A. Update feeder size. Changes clouded.======NEW APARTMENT 6 UNIT BUILDING.  600 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.  NO FIRE ALARM VARIANCE NEEDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17724	15041-10000-00926	1600 N CAMPUS ROAD AGC	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	PIN	34.12750533	-118.21285206	Energy plan check for a campus TI; indoor and outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17725	16041-10005-45243	8654 N MASON AVE	91306	3	195B109   357	2781007024	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Issued	03/29/2017 12:00:00 AM	ADDRESS	34.22794	-118.57961	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE INCLUDE ADDITION OF MODULES BACK AND 1 MORE. SYSTEM NOW USES 23 MODULES. INCREASED INVERTER SIZE TO 6KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17726	14041-10001-07089	9713 W OAKMORE ROAD	90035	5	129B165   745	4307016006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.04779	-118.39918	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL  A 7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000-US-ZB-U(28)MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17727	15041-10000-12192	19550 W NORDHOFF ST	91324	12	195B117     9	2783028062	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Expired	05/18/2017 12:00:00 AM	ADDRESS	34.23529	-118.55947	NEW FIRE ALARM SYSTEM WITH 94 FIRE ALARM DEVICES AND ONE CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17728	15041-10000-16469	8385 N LAUREL CANYON BLVD	91352	6	192B165   367	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.2231	-118.39669	ALTERATIONS IN AN AT&T RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17729	19041-10000-15422	20700 S DENKER AVE	90501	15	054B193   283	7351020017	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Issued	04/26/2019 12:00:00 AM	ADDRESS	33.84318	-118.30379	Remove outdoor HID fixture and replace with new LED fixtures -T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17730	14041-10000-22523	6805 N HAZELTINE AVE	91405	6	183B153  1082	2217014081	[Q]C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.19442	-118.44016	PC FOR T24 ENERGY. PC BASED ON ENERGY CODE 2008.INTERIOR TENAN IMPROVEMENT & INSTALL  ACCESSIBLE RESTROOMS. & RE-STRIPING PORTION OF PARKING LOT FOR  ADA PARKING. TOTAL AREA 1606 SQ FT.B# 14016-10000-12467.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17731	10041-10000-09666	101 S THE GROVE DR C10	90036	4	138B177  1131	5512003038	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Closed	09/29/2010 12:00:00 AM	ADDRESS	34.07256	-118.35874	TI , WONDERLAND BAKERY.  EXISTING PANEL ENREGY AND T24. SUITE C-10	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17732	18041-10000-18958	777 S SANTA FE AVE 2nd Flr	90021	14	124-5A217 361	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	Full plan check for an office T.I located in the 2nd floor of a 2-story building with same service supplying the whole building. Scope includes new lighting and equipment. Total area is 39,103 SQ FT. Note. 1st floor is under separated permit (18041-10000-18947) change of use office T.I.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17733	11041-10000-15388	800 S FIGUEROA ST	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.04771	-118.26116	TI TO AN EXISTING OFFICE BUILDING ON THE 11TH FLOOR.  T-24 WITH EMERGENCY LIGHTING.  OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17734	15041-20000-25020	21205 W ROSCOE BLVD Lobby	91304	3	192B105   710	2779008***	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Apartment			08/04/2015 12:00:00 AM			PC Approved	08/07/2015 12:00:00 AM	ADDRESS	34.22001	-118.59415	Plan check for Title 24 only. Project site is an existing commercial building (apartments). Project scope is a tenant improvement to the front lobby. Total lighting area =  392 sq. ft. indoor and 160 sq. ft. outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17735	19041-10000-19029	707 W WILSHIRE BLVD LL 2	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.04893	-118.2572	PC ENERGY ONLY FOR INTERIOR REMODEL ON LOWER LEVEL 2 OF AN (E) OFFICE BUILDING. SCOPE OF WORK AREA 1,825SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17736	13041-20000-08662	920 W DOWNEY WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.02063	-118.28879	Replace a 1000A switchboard with a new 1000A switchboard.  Install one new panel, elevator 25 hp motor, and lighting.  Site is in a METHANE ZONE.  USC Beigler Hall of Engineering.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17737	19041-20000-43817	3522 N GRIFFITH PARK BLVD	90027	4	154-5A203 334	5592002012	R1-1	Central	Hollywood	Los Feliz		1882.02	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM			Corrections Issued	10/25/2019 12:00:00 AM	ADDRESS	34.11594	-118.27509	NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH POWER OPTMIZERS AND (2) ENERGY STORAGE SYSTEM, 27KWH ESS. TOTAL SYSTEM SYSTEM IS 15.2 KWAC/17.01 KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17738	16041-20000-06639	6917 N WINNETKA AVE	91306	3	183B113   619	2135031004	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.19627	-118.57118	PV1.ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17739	12041-10000-27993	19010 W WYANDOTTE ST	91335	3	186B121   959	2104035007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.2029	-118.54743	PV1 4.16KW ROOF-MOUNT ENPHASE MICROINVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17740	15041-20001-05963	348 W 70TH ST	90003	9	102B201   553	6012011058	R2-1	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Un		2393.10	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	33.97628	-118.28004	Restamp for lost plans.        Installation of new roof mounted solar PV microinverter array.  Total system size = 5.59 kWacNote: PV plan check over the counter because B contractor can not pull permit online.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17741	18041-20001-21440	17044 W MIDWOOD DR	91344	12	216B133   454	2607001017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM			PC Approved	06/20/2018 12:00:00 AM	ADDRESS	34.28698	-118.50358	Expedite per applicant requestPlan check for PV battery back up system, system size7.6kWac with 14 modules, 1 inverter(7.6kW), 9.8kWh LG Chem.  connected to 200A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17742	14041-20001-10839	4958 N CARPENTER AVE	91607	2	171B169   846	2355013017	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2014 12:00:00 AM			Corrections Issued	07/11/2014 12:00:00 AM	ADDRESS	34.161	-118.3909	Modification of approved set.  Change of location of equipment.  Proposed rooftop layout of modules unchanged.  PV1 SINGLE FAMILY DWELLING USING ENPHASE MICROINVERTER ENPHASE M215. USING STANDARD PLAN. TOTAL SYSTEM SIZE 5.18KW AC USING 24 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17743	15041-10000-05395	3201 S HOOVER ST	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	Full plan check for a central plant in a single story building (USC village, bld #1). Scope of work includes medium voltage, and all work is under building #1 only. note. customer paid with preprint check, and there are (6) lighting circuits need to be paid when permit is pulled.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17744	19041-10000-09641	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Info Complete	03/18/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	Plan check for T24 only, Tenant Improvement of LAX Terminal 4 to baggage service office and parcel post office. New lights and power from existing branch circuit in the area. Total area under the SOW: 360 sq.ftB# 17016-10000-33719	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17745	18041-20000-41426	724 N CROFT AVE	90069	5	141B173   341	5528002098	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	05/21/2021 12:00:00 AM	ADDRESS	34.08433	-118.37408	new fire alarm system for apartment building.  110 devices with facp.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17746	13041-20000-11476	5928 N VAN NUYS BLVD	91401	4	177A151   188	2245003001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			PC Approved	05/03/2013 12:00:00 AM	ADDRESS	34.17836	-118.44838	T24 FOR EXISTING MUSIC STUDIO. 1412 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17747	15041-10000-06939	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			03/10/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.09918	-118.32644	New Fire alarm system for a new  HIGH RISE  apartment building (7-story). scope includes (2) fire alarm panels, (1) annunciator, (28) power supplies, and (1052) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17748	19041-20000-23077	1016-1020 N WHITE KNOLL DR	90012	1	136-5A213  19	5406022028	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	05/12/2021 12:00:00 AM	ADDRESS	34.06996	-118.24646	1200A 240/120V 1ph-3w service.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17749	18041-10000-35865	3812 W WASHINGTON BLVD	90018	10	126B185   992	5060017002	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.03965	-118.32647	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17750	13041-20000-24036	404 S IRVING BLVD	90020	4	135B189   423	5504012016	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.06681	-118.31832	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 2.7KW AC USING 13 MODULES. USING ENPHASE MICROINVERTER M215. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17751	13041-10000-11112	3900 E CHEVY CHASE DR	90039	4	159B205   748	5593002907	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.13327	-118.27281	PLAN CHECK FOR FIRE ALARM SYSTEM WITH 60 DEVICES AND A FIRE ALARM CONTROL PANEL. CENTRAL SERVICE YARD CRAFT SHOP # 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17752	13041-10001-28792	5819 N CAPISTRANO AVE	91367	3	174B101    38	2040042003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.17675	-118.617	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL INVERTER STANDARD PLAN. SYSTEM SIZE: 8.25 kW DC.(33) TRINA SOLAR # TSM-250(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17753	13041-10000-00123	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Issued	06/13/2013 12:00:00 AM	ADDRESS	33.94955	-118.38214	pH Neutralization system. Application was generated for fee estimate.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17754	14041-10001-35635	12490 W FIELDING CIR	90094	11	102B161  1250	4211034031	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	33.9788	-118.41237	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE REMOVAL OF 24 DOMELIGHTS AND ADDITION OF 10 DEVICES. ALL CHANGES NOTED DELTA 5,6 AND 7 ON THE PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17755	17041-20000-17683	515 S FIGUEROA ST #102	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI to (E) commercial space for future tenant move-in.  Plan check for lighting controls and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17756	19041-10000-35618	16929 W SIMONDS ST	91344	12	213B133   856	2682026012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.27658	-118.50091	Plan check for a PV1 7.6KW AC / 10.1KW DC roof mounted system. Scope includes (1) inverter,  (31) modules and optimizers interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17757	13041-10000-10346	5555 S WESTERN AVE	90062	8	108B193   873	5005031032	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM			PC Info Complete	07/02/2013 12:00:00 AM	ADDRESS	33.99147	-118.30913	FULL PLAN CHECK FOR ELECTRICAL ON NEW METRO PCS HUB ON FIFTH FLOOR OF 555 S WESTERN AVE. SITE IS UN-MANED AND AIR CONDITIONED. NOT A CPUS PER FY. NOTE TO PLAN CHECKER: VERIFY BUSWAYS AND BUSWAY FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17758	17041-20000-17785	10436 N SEPULVEDA BLVD	91345	7	207B145   770	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	PIN	34.26014699	-118.46691028	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT/FIRST TIME TENANT AT MEDICAL OFFICE SUITE (2,200 SF) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17759	16041-10000-05065	2633 E CESAR E CHAVEZ AVE	90033	14	127-5A225  16	5177033029	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.0454	-118.20418	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTING COMMERCIAL RESTAURANT. SCOPE INCLUDES ONE NEW 200A PANEL, AND NEW LIGHTS. ALSO NEW RECEPTACLES IN THE KITCHEN/BATHROOM/DINING AREAS. TOTAL AFFECTED AREA IS 836 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17760	17041-10000-41924	444 S SAN VICENTE BLVD #108.1	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.07021	-118.37547	PC FOR MEDICAL FACILITY. TENANT IMPROVEMENT IN VACANT SHELLED SPACE TO HOUSE OUTPATIENT PHYSICAL THERAPY DEPARTMENT.SCOPE OF WORK INCLUDES NEW CIRCUITS AND LIGHTING.TOTAL EFFECTED AREA IS 1887 SQ FTB# 17016-10000-34375	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17761	11041-10000-18125	4101 S CRENSHAW BLVD	90008	8	114B185   323	5032002066	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM			Corrections Issued	10/06/2011 12:00:00 AM	ADDRESS	34.00994	-118.33552	T.I.  ExistingWalmart.  Remodel of the pharmacy, visual, and freezer are.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17762	14041-20000-07626	4515 N ENCINO AVE	91316	5	165B129   105	2290019006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	34.15154	-118.51415	PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 7.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17763	14041-10000-34259	2207 S VERMONT AVE	90007	8	123B197   171	5054023023	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.03607	-118.29179	EXISTING 1 STORY OFFICE BUILDING ADDITION TO 2 STORY OFFICE BUILDING.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17764	17041-10000-24720	1350 N IVAR AVE	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	11/02/2020 12:00:00 AM				PC FOR SHELL  AND CORE FOR MIXED-USE COMMERCIAL DEVELOPMENT WITH 3 LEVELS BELOW GRADE PARKING FOR POWER AND ENERGY.SCOPE INCLUDES 3 SERVICES :TWO  5000A 277/480 AND ONE 4000A 277/480TOTAL AFFECTED AREA (INDOOR +OUTDOOR)  680682+82107=762789 SQ.FT.B# 15010-10000-04706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17765	19041-10000-08789	2700 N VERMONT AVE	90027	4	153B193   686	5593002913	OS-1XL	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.11803	-118.29221	GREEK THEATRE - REDWOOD DECK PROJECT.REPLACE EXISTING EXTERIOR SEATING DECK LIGHTING & INTERIOR STPORAGE ROOMS. INSTALL NEW PANEL, CIRCUITS & LIGHTING.  NOT A PLACE OF ASSEMBLY, ALL WORK IS DONE OUTSIDE AND IN STORAGE AREAS.PLAN CHECK FOR ENERGY ONLY SINCE THE SCOPE OF WORK IS NOT INSIDE THE THEATRE AREA. BULDING PERMIT: 18016-10000-36620	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17766	15041-20000-42581	4942 N CARPENTER AVE	91607	2	168B169    49	2355013019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.16058	-118.39091	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.3KWdc/5.0KWac.(20)MODULES-KYOCERA #KU2656ZPA(1)INVERTER- ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17767	16041-10000-36823	6041 W CADILLAC AVE	90034	10	126B173  3011	5066002029	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.03806	-118.37594	Full Plan check for a new 5 level parking structure with connection to an existing 5 level parking structure. New 600 A serice 480/277V 3 phase 4 wire. All new equipment. Installing new lighting and power. Totalsqft = 188,065.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17768	12041-20000-00010	9301 N TAMPA AVE Spc # 210	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	Existing restaurant space remodeled for new restaurant tenant.  New lighting and new ckts, no new panels.  Restaurant is located at the Northridge Fashion Center space # 210.  The modified load is less than 400 amperes based on the engineers calculation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17769	13041-20000-33704	721 N EL MEDIO AVE	90272	11	129B125   763	4413013007	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.04599	-118.53356	PV1 SINGLE FAMIYL DWELLING. TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER ENPHASE M215. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17770	12041-10000-26259	10425 W VENICE BLVD	90034	5	117B165    77	4314003017	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.02037	-118.40486	CHANGE OF USE TO A MARKET / DELI. EXISTING 600 AMP 120/240 VOLTS SERVICE FOR THREE TENANTS AND EXISTING PANEL TO REMAIN. PLAN CHECK FOR POWER AND T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17771	19041-20000-01310	2314 W PICO BLVD	90006	1	129B197  1079	5056004004	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Apartment			01/11/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.04707	-118.28712	600 amp service upgrade  reconnecting to existing unit panels(16).plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17772	17041-10000-43255	1365 E 6TH ST	90021	14	126A217   125	5164008011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.03834	-118.23375	REPLACE EXISTING FIXTURES WITH LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 22650 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17773	16041-20000-01610	1843 S FAIRFAX AVE	90019	10	126B173   563	5066017021	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.04191	-118.36988	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW, ungrounded system. (11) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17774	11041-10000-16680	421 N HENRY FORD AVE AREA # 4	90744	15	027B213     1	7440011270	M3, M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	33.77533	-118.24134	ADDING FOUR NEW OIL WELL MOTORS, FEEDERS, AND VFD'S.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17775	15041-20000-06702	6616 N IRVINE AVE	91606	2	180B169   528	2320025008	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.19093	-118.38543	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (27) modules, (1) inverter, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17776	16041-20002-36712	7511 W ALPINE WAY	91042	7	213B197    79	2552043019	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.27748	-118.29582	Revisions to approved set of plans.  Changes to roof equipment layout, minor wiring detail changes. (((Plan check for a PV1 roof-mounted PV system. System size is 13.5 kWac and consists of (54) modules, (54) micro-inverters, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17777	15041-30000-38779	7900 S NARDIAN WAY	90045	11	099B157    74	4113022027	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	33.9666	-118.42039	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.44 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17778	15041-20000-09154	9126 N PATRICK AVE	91331	6	198B161   572	2628005005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Expired	04/21/2017 12:00:00 AM	ADDRESS	34.23523	-118.41516	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 10kW (5+5). Ungrounded system. (30) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17779	19041-20000-50126	4830 N NOMAD DR	91364	3	168B113   145	2175017003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Issued	12/18/2019 12:00:00 AM	ADDRESS	34.15889	-118.56786	PV1.  Install 8.06886 kW rated solar roof system and 27 kWh energy storage system.  (138) shingle modules and 5.2 and 3.8 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17780	14041-10001-24450	940 N MALTMAN AVE	90026	13	142-5A203 171	5427022021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	10/30/2014 12:00:00 AM	ADDRESS	34.08556	-118.27997	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 5.865 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(23) MODULES: KYOCERA KD255GX-LFB3(1) SOLAREDGE SE5000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17781	10041-20000-14951	7899 S LA TIJERA BLVD	90045	11	099B169  1006	4106030020	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM			PC Info Complete	08/02/2010 12:00:00 AM	ADDRESS	33.96518	-118.3857	PLAN CHECK T-24 ENERGY GENERAL/EMERGENCY LIGHTING  FOR NEW CLASSROOM & OFFICE ON 1ST FLOOR AND NEW CLASSROOM ON 2ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17782	13041-20000-35917	11734 W REMINGTON ST	91342	7	213B169   484	2531023029	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.28107	-118.38847	PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17783	17041-10001-08208	929 W JEFFERSON BLVD	90007	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM			PC Approved	05/24/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	Chagnes to approved set.  All changes clouded.  Updated fixture locations and revised circuiting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17784	11041-20000-25904	12301 W WILSHIRE BLVD	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/06/2011 12:00:00 AM	PIN	34.04277409	-118.46969044	Existing dental office.  Adding 3  receptacles (new branch circuits Ckts 21, 23, 24) and no new additional lighting.  Plan check is for power only.  A permit for teh work has already been pulled under 11041-20000-18923	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17785	10041-10000-00391	9185 N DE SOTO AVE	91311	12	198B109   127	2746009022	(T)(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/08/2010 12:00:00 AM	05/24/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.23801	-118.5888	New restuarant (McDonalds).  New service, panels, circuits, and indoor/outdoor lightings.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17786	18041-20000-07681	16122 W SATICOY ST	91406	6	186B141    80	2205021018	[T][Q]MR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.20824	-118.48446	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the replacement of existing fixtures with LED fixtures. Total lighting area = 2,375 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17787	18041-10000-41073	854 W EL SEGUNDO BLVD	90247	15	081B197   341	6117022025	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.91626	-118.29099	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17788	18041-20000-26425	2189 E WHITTIER BLVD A	90023	14	124-5A221 121	5183021023	R3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	Yes	2060.50	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.03614	-118.21937	Plan check for Title 24 Energy only in existing building T.I. in retail space 7 Eleven Total newly connected load is less than 400A. Total area: 2060 sq ft. B#18016-20000-22247	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17789	14041-20001-13081	947 N RIVAS CANYON ROAD	90272	11	129B129   688	4409005017	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.04757	-118.51497	Expedite per customer requestPV1 roof-mounted system with 13.3kw, (48) Sun Power SPR-327NE-WHT-D modules, and (2) Sun Power SPR-6000m string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17790	15041-10000-24597	811 W 7TH ST 2ND FLR-BLDG MANGE	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.04908	-118.25911	PC FOR ENERGY ONLY, T-24 TO (E) HIGHRISE OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND NEW RECEPTACLES. CONNECTED LOAD IS <400 AMPS. TOTAL SQ. FT. 1165	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17791	15041-10003-39684	10250 W SANTA MONICA BLVD MACYS	90067	5	132B161    24	4319003066	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	THIS IS PLAN CHECK FOR CHANGES CLOUDED IN BLUE. CHANGES INCLUDE CIRCUIT DESIGNATION CHANGES AND WIRE ROUTING. NO CHANGE TO COUNTS OR T24 COMPLIANCE. THIS IS PC ONLY. PERMIT ALREADY COVERED UNDER MASTER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17792	16041-20000-21222	10344 W DIAMOND ST LOT 13	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17793	12041-10000-05595	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	33.79173	-118.23549	SCOPE OF WRK IS THE CONNECTION  OF GROUNDING CONDUCTORS OF ELECTRICAL EQUIPMENT TO THE EXISTING GROUND LOOP AT THE TESORO REFINERY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17794	19041-10000-52428	888 S FIGUEROA ST SUITE 700	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.0465	-118.26225	TENANT IMPROVEMENTS IN OFFICE SPACEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17795	19041-20001-10404	16909 W ARMSTEAD ST	91344	12	213B133   224	2610009004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.28259	-118.50024	expeditepv1install roof mounted pv system sized 7.6KW AC with battery 5KW interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17796	13041-20001-35977	5643 N WILHELMINA AVE PV1	91367	3	174B089   427	2046014005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	34.17235	-118.64966	EXPEDITE FEES ONLY.<<<New rooftop PV system for an existing single family dwelling.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17797	16041-10000-33811	2710 E 5TH ST	90033	14	124-5A223  17	5185010008	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.03718	-118.20853	PV , INSTALL NEW 3.27 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(10)MODULES AND AC INVERTERS :SPR-E20-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17798	18041-20000-15841	20625 W CHESTNUT CIR (#276)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.29318	-118.58345	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17799	17041-20000-17793	8301 N CANOGA AVE	91304	3	192B105   594	2779036013	C2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.22025	-118.59775	New panel feeding gas pumps/dispensers for service station.  Hazardous classification.Service station permit with new 400A service issued under 16041-20000-11387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17800	19041-20001-17198	3536 N LOWRY ROAD	90027	4	153A203    29	5592008001	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM			PC Approved	07/05/2019 12:00:00 AM	ADDRESS	34.1156	-118.27781	07-05-2019 Changes to an approved set of plan, Changes include addition of Energy storage Disconnect. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17801	14041-10001-27470	663 N LA FAYETTE PARK PL	90026	13	139-5A203  45	5402005002	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/27/2014 12:00:00 AM	ADDRESS	34.07806	-118.27393	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(6) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB # PVI-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17802	13041-10000-24021	18911 W GRANADA CIR	91326	12	216B121   403	2872010043	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.28684	-118.54393	PV1. ROOF MOUNTED SOLAR ARRAY. CENTRAL INVERTER. STANDARD PLAN. SYSTEM SIZE: 6.615 kW. 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17803	11041-20000-03755	6420 W WILSHIRE BLVD 6th Floor	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check T24 Energy/Emergency lighting for Interior tenant improvements on the 6th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17804	11041-20000-08555	13248 W ROSCOE BLVD	91605	2	192B157   695	2304006036	RA-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Apartment			04/28/2011 12:00:00 AM			PC Info Complete	04/28/2011 12:00:00 AM	PIN	34.22115898	-118.42178729	T.I.  to existing building.  Install general lighting in restroom.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17805	19041-20000-44638	5335 W ADAMS BLVD	90016	10	123B177   919	5043002029	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Apartment			10/31/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.03268	-118.3593	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. 247 FA DEVICES AND 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17806	17041-10000-09330	9779 W OAK PASS ROAD	90210	5	156B157   517	4385014030	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.11983	-118.42761	PC FOR POWER ONLY. ALTERATION TO AN EXISTING ACCESSORY LIVING SPACE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17807	17041-20000-37862	925 W WEST 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.0239	-118.28647	Plan check for energy only. TI to telecom rooms in USC Dentistry building. New lighting - 846sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17808	18041-10000-09080	4235 N BRUNSWICK AVE	90039	13	159B205   566	5594009017	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.12989	-118.26869	NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 3.0KWdc / 2.8KWac. PV SYSTEM IS  CONNECTING TO THE POINT OF INTERCONNECTION OF A SINGLE FAMILY HOME.(10)MODULES-SOLARWORLD SW 300(10)MICROINVERTERS-ENPHASE S280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17809	16041-10002-14259	10614 N DEBRA AVE	91344	12	207B137   549	2679015024	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM			PC Approved	08/17/2016 12:00:00 AM	ADDRESS	34.26324	-118.48924	CHANGES TO APPROVED SET OF PLANS. CHANGE INCLUDES USE OF SUBPANEL TO RELOCATE EXISTING LOADS. INSTALLATION SHALL BE AS PER THIS SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17810	12041-10000-09162	12222 W WILSHIRE BLVD Unit #101	90025	11	126B145   356	4263001***	[T][Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM			PC Approved	04/20/2012 12:00:00 AM	ADDRESS	34.04288	-118.46867	Existing restaurant will take over existing adjacent restaurant to make one larger restaurant.  PLAN CHECK  for Energy with Emergency lighting.  Existing Panels, Permit was issued for 14 new circuits.   Load is 200A and occpuancy load is less than 99, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17811	16041-20000-11029	18535 W BURBANK BLVD	91356	3	174B125   372	2160003004	(T)(Q)R3-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			04/11/2016 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.1725	-118.53724	NEW THREE STORY (14 UNITS) APARTMENT BUILDING - TYPE VA - OVER ONE LEVEL OF OPEN PARKING GARAGE BASEMENT - TYPE IA.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17812	10041-20000-01627	3900 W MIDDLEBURY ST	90004	13	141B197  1219	5539032039	(Q)R3-1XL	Central	Wilshire	East Hollywood	YES	2170.00	Electrical	Electrical	Apartment			01/29/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.07966	-118.28962	NEW 17 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17813	13041-20000-35203	7043 N DELCO AVE	91306	3	183B109   324	2136003014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.19868	-118.57876	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9KW AC USING 2 TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 44 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17814	18041-30000-27021	1265 S BARRY AVE 1-18	90025	11	129B145   740	4263011011	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.03	Electrical	Electrical	Apartment			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.04834	-118.45886	PLAN CHECK FOR A FIRE ALARM SYSTEM LOCATED IN A NEW 3-STORY 18-UNIT APARTMENT BUILDING OVER 1-STORY SUBTERRANEAN GARAGE. SCOPE INCLUDES (1) FIRE ALARM PANEL, (1) POWER SUPPLY AND (85) FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17815	11041-10000-11763	424 E WASHINGTON BLVD	90011	9	121-5A207  18	5127019015	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	06/08/2011 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	PIN	34.02883464	-118.26080424	TI, EXISTING SINGLE STORY BUILDING IN A SHOPPING CENTER.  SINGLE RETAIL UNIT IS BEING SPLIT INTO TWO SEPERATE RETAIL UNITS.  T-24 OTC PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17816	16041-10000-42452	3373 S CABRILLO BLVD	90066	11	114B149   312	4247017007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.01022	-118.44582	PV1. NEW SOLAR SYSTEM ON EXISTING EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(15)MODULES-CANADIAN SOLAR 290W(1)INVERTER-DELTA SOLIVA 3.8 TL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17817	11041-20000-09725	6600 N TOPANGA CANYON BLVD #2075	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to existing building.  Install general/emergency lighting.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17818	15041-20000-12607	11950 W FOOTHILL BLVD	91342	7	210B165    41	2532012039	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Pacoima		1041.08	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM			Reviewed by Supervisor	05/08/2015 12:00:00 AM	ADDRESS	34.2757	-118.3967	Plan check for power and Title-24 (energy).  Total area = 19,397 sq. ft.  Remodel of existing building.  Installation of electrical distribution equipment and plug loads for new retail store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17819	10041-10000-07176	830 N VERMONT AVE	90029	13	141B197    37	5539015024	[Q]C2-1	Central	Hollywood	East Hollywood	YES	1914.20	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.08631	-118.29154	renovation of a jackin- the box restaurantplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17820	19041-10000-02154	4151 W PROSPECT AVE Room 114E	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for an office T.I loacted in room 114E of a commercial building. Scope include new lighting and receptacle with a total of 154-SQ FT. No architectural changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17821	16041-20000-32618	16030 W VENTURA BLVD STE 250	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.15598	-118.48247	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHTING.  SCOPE TO BE PERFORMED IN SUITE 250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17822	12041-10000-23280	110 E 9TH ST # A979	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM			PC Approved	10/01/2012 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR SUITE #A979 TI. TOTAL INSTALLATION LESS THAN 400A LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17823	17041-10000-01900	13550 W PAXTON ST	91331	7	210B157  1078	2535002018	M1-1-CUGU, M2-1-CUGU, M2-1-O-CUGU, M3-1-CUGU, M3-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.27276	-118.42714	Plan check for hazardous location, add 3 new fuel deispensers to existing gas station (Costco)B#17041-10000-00177	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17824	19041-20000-37206	6100 W CENTER DR 11th floor	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	33.97733	-118.3922	Restroom remodel on 11th floor of (E) office building P.C for title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17825	18041-20000-47500	341 N WEST CHANNEL ROAD	90402	11	123B129   800	4410022006	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	11/09/2020 12:00:00 AM	ADDRESS	34.0306	-118.51439	Plan check for PV roof mounted with energy storage system, PV system size: 7.56kW DC, 6.7kW AC with 21 AC Modules, SONNEN BATTERY SYSTEM ECO 16. connected to  existing 400A service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17826	18041-20000-29663	8019 W WOODROW WILSON DR	90046	4	156B173   397	5570019039	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	08/11/2018 12:00:00 AM	ADDRESS	34.12271	-118.37313	Plan check for PV roof mounted system system size: 7.6KW with 23 modules and 1 inverter(7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17827	17041-10000-38205	16333 W RAYMER ST	91406	6	189B137   131	2205029049	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.21814	-118.48811	PC for T24 only for replacement of existing fixtures with LED fixtures. Total 60200sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17828	13041-10000-25088	458 S ALAMEDA ST	90013	14	127-5A215 415	5163026008	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.04162	-118.23803	TITLE 24 PLAN CHECK ONLY. 1 STORY. 10822 SQFT. WAREHOUSE. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17829	19041-10000-53934	1266 W 82ND ST	90044	8	099B197  1319	6033011031	R1R3-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	33.96428	-118.29816	[E-Plan] Installation of 8 solar PV modules @2.640kw to an existing 5.280kw system which totals the module count to 24 and brings system size to 7.920kwDC/7.396kwAC-CEC /7.6kw AC. Existing inverter will be swapped from a 5000H to a 7600H. Everything else remains in the original location.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17830	16041-10001-35856	318 E 2ND ST #B	90012	14	129A213   100	5161022012	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Closed	11/09/2016 12:00:00 AM	ADDRESS	34.04881	-118.24129	10/31/16Changes to an approved set of plans. Changes include relocating/adding/removing lighting fixtures. Floor plans to reflect what is on the field. New affected area is 2385 SQ. FT.Note: Permit is paid under PCIS#16041-10000-35856((((((((T-24, PC FOR ENERGY ONLY. CHANGE OF USEA PORTION OF THE 1ST FLOOR (E) RESTAURANT (COCKTAIL LOUNGE) TO T-MOBILE RETAIL, OFFICE  AND STORAGE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1445 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17831	16041-10001-08104	10828 N AQUEDUCT AVE	91344	12	207B141   153	2662022006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.26732	-118.47385	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.18KWdc / 7.31KWac(34)MODULES-SILFAB SOLAR SLA-M 270W(34)MICROINVERTERS-ENPHASE M215-60-2LL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17832	17041-10000-17163	2616 N FIGUEROA ST	90065	1	142-5A219 150	5446017008	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.08414	-118.22175	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 3,700 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17833	12041-20000-23088	6300 W WILSHIRE BLVD STE 1800	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for energy and emergency lighting. Suite 1800. High rise commercial. 9989 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17834	19041-10000-06920	218 N LARCHMONT BLVD	90004	4	138B189   584	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.07535	-118.32345	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17835	18041-10001-08918	3507 S GRAMERCY PL	90018	8	120B189   930	5042030019	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM			PC Info Complete	05/16/2018 12:00:00 AM	ADDRESS	34.02428	-118.31395	DELTA 1 CHANGES TO THE APPROVED PLANS. REDUCED THE NUMBER OF PV MODULES FROM 15 TO 14.   <<<PC for new rooftop solar for 4.2kW rooftop solar in SFD. Installing 15 modules (4.5kW) and ABB central inverter. See comments.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17836	19041-10000-40819	22835 W VICTORY BLVD	91307	12	180B097   434	2038040031	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	03/18/2020 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.1866	-118.62527	T-24 ONLY PLAN CHECK FOR A TI TO AN (E) BURLITINGTON SPACE IN AN (E) SHELL. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL CONNECTED LOAD IS LESS THAN 400A. TOTAL AFFECTED AREA IS 95324 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17837	15041-10000-05456	11507 W OXNARD ST UNIT-B,C,E	91606	2	177B169   797	2338004012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Closed	07/14/2015 12:00:00 AM	ADDRESS	34.1796	-118.38271	Energy plan check for an office T.I in a second floor of a commercial building; Total area is 2340-SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17838	13041-10000-00795	18931 W DEARBORN ST	91324	12	198B121   607	2762025028	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2013 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.23753	-118.54602	PV1. SINGLE FAMILY DWELLING SINGLE STORY. PHOTOVOLTAIV USING FRONIUS IG PLUS V 10.0 INVERTER. SOLAR PANEL - KYOCERA KD 220GX - LFBS. 11.44KW SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17839	16041-10000-01438	3501 S LA CIENEGA BLVD	90016	10	120B173   365	4205029010	[Q]C4-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Issued	08/03/2016 12:00:00 AM	ADDRESS	34.02395	-118.37251	TI on an (E) McDonald. Lighting alteration using existing circuits. Total area: 3415 sq.ft. PC for Energy only.1/14/16 Correction issued	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17840	14041-10001-30464	500 S SANTA FE AVE	90013	14	126A217   245	5164004010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.04107	-118.23124	"02/22/17Changes to an approved set of plans. All changes are clouded under delta 2. Changes include replacing the supply side feeder conductor from (10) 4""C 4#600MCM copper  to (11) 4"" 4#750MCM aluminum. Note: Permit is paid under PCIS#14041-10000-30464"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17841	12041-10000-14788	6222 W SANTA MONICA BLVD	90038	13	144B189   698	5534022033	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	ADDRESS	34.09053	-118.32534	Change to lighting and receptacles for an existing 2-story office building.  Load is 260.7A.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17842	10041-10000-19272	600 W WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	REPLACEMENT OF 14 ESCALATORS AT LAWA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17843	14041-20000-16263	3470 S MCCLINTOCK AVE	90089	9	120A201    44	5039012030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.0236	-118.28768	Plan check for power and energy. New lighting along exterior pathway on University of Southern California campus. Location in methane zone. Classified location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17844	17041-20000-43270	1475 S BEVERLY DR 1-18	90035	5	129B165   154	4306009031	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.05296	-118.39563	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17845	11041-20000-16212	1212 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/08/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29205	"New 3.23 Kw Pv solar equipment ( max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) system for an apartment Bldg"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17846	14041-10000-10652	15853 W MONTE ST STE #107	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.31022	-118.47637	T24 ONLY, REMOVING HID  FIXTURES AND REPLACING WITH NEW FLORESCENT ONE. TOTAL AREA 3184 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17847	13041-10001-16925	520 S OLIVE ST	90013	14	129A211    32	5149031900	OS-1XL	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.0488	-118.25326	Title 24 and energy. single story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17848	09041-10001-21978	8500 W BEVERLY BLVD # 735	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	03/22/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I.  REMODEL OF EXISTING  RETAIL  SPACE ; revise power plan  and lighting plan lay outs ; no significant changes to the emergency lighting and exit signsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17849	19041-20000-32388	2923-2927 N ALLESANDRO ST	90039	13	150B213   792	5442025022	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/19/2019 12:00:00 AM	02/07/2023 12:00:00 AM		Permit Finaled	02/27/2024 12:00:00 AM	ADDRESS	34.10472	-118.24587	1200A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17850	15041-20001-26399	11501 W DUQUE DR	91604	2	156B169   116	2381022002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.12715	-118.38472	Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 11.07 kW.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17851	19041-20001-35464	9451 N CORBIN AVE	91324	12	198B117    68	2761040016	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			PC Approved	09/10/2019 12:00:00 AM	ADDRESS	34.24147	-118.56249	CHANGES TO APPROVED SET DELTA 1 ONLY. REMOVE DAY LIGHT CONTROL. <<<T24 PLAN CHECK FOR NEW LIGHTS ONLY IN EXISTING LOW RISE COMMERCIAL BUILDING. TOTAL SQUARE FOOTAGE = 29,060 SF>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17852	19041-20000-00221	6548 N VARNA AVE	91401	2	180B157   561	2329022005	RS-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.1897	-118.42456	PC FOR PV SYSTEM. SYSTEMINCLUDE 7.20KW DC AND 6.12 KW AC. WITH 20 JA SOLAR MODULES AND POWER OPTIMIZERS. ONE CENTRAL 7.6W INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17853	11041-20000-04217	707 W WILSHIRE BLVD 50th Floor	90017	9	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.04893	-118.2572	T.I. to existing high rise building.  Install general/emergency lighting partial of 50th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17854	16041-20000-00547	16836 W BOSQUE DR	91436	5	165B133   247	2291003005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.14957	-118.49954	Plan check for PV roof mounted system. System size: 15kW with 50 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17855	16041-10000-41779	17303 W OSBORNE ST	91325	12	195B133    85	2768021001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.23355	-118.51173	PV INSTALL NEW 7.920 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(22) AC MODULES: SPR-X22-360-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17856	14041-20001-31421	14624 W SHERMAN WAY #101	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM			PC Approved	12/22/2014 12:00:00 AM	ADDRESS	34.20102	-118.45165	12.22.2014 - Plan check for power only - medical facility.[Permit for panels and branch circuits.  Note: Lighting plan check is under 14041-20000-31024]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17857	13041-10000-14361	6500 W WILSHIRE BLVD 8th fl	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.06371	-118.3703	13041-10000-14361renovations in an existing officeplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17858	11041-20001-15360	16027 W VENTURA BLVD suite# 210	91436	5	168B141   538	2261022106	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	ADDRESS	34.15641	-118.48225	TI in an existing Office. EPC is for T24 & Emergency lights. (permit was pulled uder# 11041-90000-15360)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17859	18041-10000-17659	3050 S CAVENDISH DR	90064	5	123B165   172	4316011018	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Issued	08/10/2018 12:00:00 AM	ADDRESS	34.0363	-118.40578	Permit fee is $0.00 due to Senate Bill 1222. Plan check for a PV1 15.34 KW DC/ 15.2KW AC roofmounted system with (54) modules, and (2) 7.6kW inverters interconnecting through the load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17860	10041-10005-01492	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	ADDRESS	34.09676	-118.29487	Modification to previously approved set of plans to show control wiring for firepump transfer switch to generator.  <<<TI - existing church of scientology -highrise>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17861	14041-20001-07626	4515 N ENCINO AVE	91316	5	165B129   105	2290019006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	34.15154	-118.51415	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 7.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17862	18041-30000-37464	601 S FIGUEROA ST 48TH FLR.	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for T24 only, on (E) office spaces 48th floor. Total area 15,000sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17863	16041-20000-40163	1446 N TAMARIND AVE	90028	13	147A191   111	5545015044	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.09701	-118.31892	NEW FOUR STORY 44 UNITS APARTMENT BUILDING.  1200 AMP SERVICE, PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17864	13041-10000-12635	4904 N PETIT AVE	91436	5	168B137   153	2259013017	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.15975	-118.49558	PV1, 1 story house.  Install roof-mounted solar array, interconnect with main panel.  2.45 KW DC system size.  {10 modules: TSM-245PA05} {Transformerless inverter: SE3000A-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17865	18041-20002-04511	6224 S FIGUEROA ST	90003	9	105B201  1037	6004038049	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	33.98261	-118.28245	10-30-2018 Changes to an approved set of plan (core and shell). Changes include change service from 1000A 120/208 to 600A 277/480V, addtion of 6 Transformers(1 75KVA, 5 45KVA), panels are to remain, some loads has been revised. All changes have been clouded.(((((((Plan check for power and energy. Project site is a new multi-tenant building. Project scope is a core and shell. Work includes a 1,000-amp service and a lighting area of 24,370 sq. ft.Note: Building application has been generated under 17010-20000-04475)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17866	13041-10000-19957	1146 W 27TH ST	90007	9	123A201   213	5055027016	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Expired	10/12/2015 12:00:00 AM	ADDRESS	34.03015	-118.28543	PV1 .INSTALLING ROOFMOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 10.78KW. 2 STORY. 1 INVERTER: FRONIUS IG PLUS V 7.5 (7500W) , 4 STRINGS, 44 MODULES : TRINA TSS-245 (245 W). NEGATIVELEY GROUNDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17867	17041-10000-31868	2649 E WASHINGTON BLVD	90021	14	118-5A219  93	5168015902	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.01755	-118.2246	PC FOR NEW SERVICE. 800A FOR FUTURE MODULAR TRAILER AND REFEED EXISTING LOADS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17868	19041-10000-30139	2400 N HYPERION AVE	90027	4	148-5A205  83	5432003008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM			PC Approved	08/02/2019 12:00:00 AM	ADDRESS	34.10277	-118.27288	ENERGY PC FOR INTERIOR TENANT IMPROVEMENT. AREA OF SCOPE 1,359SF.PERMIT IS PAID UNDER 19041-10000-35219.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17869	19041-10000-36488	536 E MANCHESTER AVE	90003	9	097-5A207 323	6041019003	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	33.95991	-118.26549	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A CHANGE OF USE FROM RETAIL TO OFFICE SPACE, SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 2962 SQFT. B#19016-10000-13427	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17870	14041-10000-12860	16750 W VIA PACIFICA	90272	11	138B121    51	4431039002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.07667	-118.54851	PV1 MICROINVERTER PLAN. 400AMP SERVICE AND GROUND MOUNTED SYSTEM. BUILDING PLAN CHECK APPROVAL REQUIRED PRIOR TO ELECTRICAL PLAN CHECK APPROVAL. TOTAL SYSTEM SIZE 8.6KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17871	10041-20000-08535	7851 N VENTURA CANYON AVE	91402	6	189B157   638	2214026008	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Apartment			05/07/2010 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.21344	-118.42899	49 units apartment variance for fire alarm on file	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17872	17041-20000-31627	2322 S DUXBURY CIR	90034	5	126B165   488	4309014015	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	08/25/2018 12:00:00 AM	ADDRESS	34.04189	-118.39598	permit fee $0.00 by state senate bill no.1222PV1.  Install 13.37 kW AC CEC roof mounted grid tied PV system.  (56) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17873	12041-10000-00018	10971 N SAN FERNANDO ROAD C,D,E	91331	7	210B157   760	2619014011	CM-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Expired	06/29/2018 12:00:00 AM	ADDRESS	34.26945	-118.42587	"New ""Commisary facility"" with 4 catering units.  New commercial building with 800A service, new circuits, and equipment with outdoor lighting.  Units C,D,E  < This permit is for the EAST Building. The Permit Number for the WEST Building is 12041-10000-00016>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17874	19041-10000-37031	19501 W LEMARSH ST	91324	12	204B117   303	2726009001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.25554	-118.55837	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 6.4KVA PV1 SYSTEM CONSISTING OF 22 MODULES USING MICROINVERTERS(IQ7PLUS-72-2-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17875	14041-10000-32964	9415 N CANTERBURY AVE	91331	6	198B153   429	2642011021	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	34.24054	-118.43626	Plan check for PV1 Roof mounted with system size: 6.0kW with 18 modules and 1 inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17876	16041-20000-36382	8905 W DEVLIN PL	90069	4	144B169    27	5560038007	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM			Reviewed by Supervisor	10/28/2016 12:00:00 AM	ADDRESS	34.09483	-118.38531	Plan check for power only. Project site is a new single-family dwelling. Work includes a new 600-amp service and related distribution equipment.Note: Building permit has been pulled under 15010-20000-01237	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17877	16041-10000-45676	1518 N ALEXANDRIA AVE	90027	13	147B197   631	5543006010	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.0988	-118.29818	PC FOR POWER AND ENERGY.T.I. CONVERT ASSEMBLY HALL TO 6 CLASSROOMS WITH NEW PARKING LOT ON EXISTING TWO STORY ELEMENTARY BUILDING. UPGRADING SERVICE TO 600 A.B 16016-100000-21628	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17878	18041-20001-00644	2343 N ALTMAN ST	90031	13	144B213   384	5445029013	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.09185	-118.23851	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17879	17041-10000-20940	18410 W KESWICK ST UNIT #8	91335	12	186B125    52	2119001***	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.21008	-118.53411	Installation of new roof mounted solar PV system on existing single family dwelling.  Central inverter system with DC optimizers.  Total system size = 5 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17880	14041-10000-31642	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016023	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Apartment			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Closed	09/17/2015 12:00:00 AM	ADDRESS	34.08758	-118.34425	Temp power by installing a 400 kva gen set for powering a future site for 179 mixed use resii.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17881	14041-10000-24945	8309 W KIRKWOOD DR	90046	4	150A173   459	5556010038	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.10497	-118.37291	PV1, 3.6KW  roof mounted syste including (1) PowerOne PVI 3.6 inverter, and (16) Kyocera KD255Gx modules interconnecting through a main service panel.note. original was 9 modules total, and custsomer upgrade to 16 modules and a 3.6 inverters during verification	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17882	17041-20000-33471	16633 W VENTURA BLVD #905	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for Title 24 only. Project site is an tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,665 sq. ft.Note: Building permit has been issued under 17016-20000-24753	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17883	12041-10000-13273	4644 W HOLLYWOOD BLVD	90027	13	147B197   451	5542014006	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Approved	06/07/2012 12:00:00 AM	ADDRESS	34.10014	-118.29065	T.I. to an existing retail space.  Load is less than 400A.  PLAN CHECK ONLY for Energy, no Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17884	17041-10001-32653	360 E 2ND ST #150-#150A	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM			PC Info Complete	11/29/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include relocating/adding lighting fixtures, revising floor plans, and revising title 24 forms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17885	16041-20001-33666	6417 N TROOST AVE 4	91606	2	180B169  1088	2335010019	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	34.18726	-118.38677	expedite per applicant.pv2install roof mounted pv system sized 3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17886	19041-10001-48417	2932 S SOMERSET DR	90016	10	120B185   181	5050019024	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM			PC Approved	12/31/2019 12:00:00 AM	ADDRESS	34.02849	-118.33724	Change to an aprroved set , change includes changing the location of junction box only *********************************************************************************plan check for roof mounted pv1 systen consisting of 10 ac modules(sunpower a425) system size 3.49kva	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17887	19041-10000-44764	23525 W WINDOM ST	91304	12	186B093   273	2027036004	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.20637	-118.641	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10.560 KW DC/10.08KW AC CONSISTING OF  32 Modules and 32 Microinverters(IQ7X)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17888	11041-20001-07558	5477 N NESTLE AVE	91356	3	174B125   498	2160018***	R3-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.1703	-118.5299	"Plan check for changes to fault current. Some panels may need replacement. Permit is on ""Inspection"" Fee Period.Upgrade to 1200 Amp service due to fire damage equipment.  Install new main panels.  Plan check for power only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17889	16041-10000-13789	8133 N REMMET AVE	91304	3	189B105    61	2110019024	[Q]CM-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.21757	-118.60049	PC for energy only. Remove HID fixtures and replace with new LED fixtures. Total sqft = 2640	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17890	18041-10000-25163	9419 S AIRPORT BLVD	90045	11	093B169    89	4124009920	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	33.95058	-118.3862	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17891	15041-10000-28233	6614 W MELROSE AVE	90036	5	141B185   610	5524017002	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	PIN	34.08319313	-118.33922028	pv2, install 9.405 kw dc roof-mounted solar array on a commercial building. (33) micronverter: enphase energy M250-60-2LL(33) MODULES: SOLAR WORLD SW 285 MONO	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17892	15041-20000-39676	11915 W WICKS ST	91352	6	195B165     9	2631004084	[T][Q]M1-1, [T][Q]P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.23478	-118.39294	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 31.36 KW.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17893	18041-10000-48404	19850 S MAGELLAN DR	90502	15	057B197    56	7351034065	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.85035	-118.29277	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17894	15041-20001-02659	12500 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/31/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17895	13041-10000-04123	6653 N FALLBROOK AVE	91307	3	180B097   183	2038040013	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	07/05/2013 12:00:00 AM	PIN	34.19123265	-118.62539509	NEW FIREALARM SYSTEM FOR 24HOUR FITNESS. 119 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17896	18041-10000-17940	3550 S OVERLAND AVE	90034	5	120B161   895	4314011050	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			05/15/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	07/13/2023 12:00:00 AM	ADDRESS	34.02383	-118.41069	New Fire alarm system (224) devices, (1) FACP on New 5-story 60-unit affordable housing apartment over 2-levels of subterranean parking. 24 Typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17897	15041-20001-22144	7514 N HASKELL AVE	91406	6	186B141   235	2206013012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			05/31/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.20712	-118.47477	5.31.2017 - Plan check for modification to approved set. Change panel MSB from 225A to 400A. Update feeder size. Changes clouded.======NEW APARTMENT 6 UNIT BUILDING.  600 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.  NO FIRE ALARM VARIANCE NEEDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17898	12041-10000-20233	8487 W 3RD ST	90048	5	138B173   683	5511013021	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.07344	-118.37533	PROPOSED TENANT IMPROVEMENT W/IN AN EXISTING RETAIL SPACE for TJ MAXX.   1ST FLOOR.  BUILDING D, suite D#107	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17899	18041-20000-30699	10250 W CONSTELLATION BLVD 27th Floor-Corridor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 Energy only in 27th Floor corridor and elevator lobby inexisting high-rise building T.I. Total area: 1353 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17900	14041-10000-35141	1455 N VAN NESS AVE	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.09728	-118.31598	NEW FIRE ALARM SPINKLER MONITORING SYSTEM WITH ( 27) DEVICES), (1) FIRE ALARM PANEL AND (1) POWER SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17901	14041-20001-27614	5264 N TUJUNGA AVE	91601	2	171B173   356	2350017010	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	34.16663	-118.37881	"10-28-2014: Plan check only for modifications to approved set. Change LED downlight fixture (HH6-LED - 6"") to LED Retrofit module (RL428 - 4""). Update Compliance forms to reflect changes. Permit pulled under permit #14041-40000-28470.TI to (E) 323 sq. ft. commercial retail space.  Plan check for changes to lighting system under Title 24 Part 6.  New lights in pick-up area, all others existing per applicant."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17902	16041-10000-44690	3662 N BARHAM BLVD (BUILDING-M)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.13907	-118.34141	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17903	16041-10001-35862	200 N FALCON ST	90744	15	021B205    25	7440019908	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Info Complete	05/21/2018 12:00:00 AM	ADDRESS	33.75579	-118.2664	CHANGES TO APPROVED PLANS IN A HAZARDOUS CLASS 1, DIV 2 LOCATION. PLANCHECK ONLY FOR POWER. CHANGES ARE CLOUDED DELTA 5D, 7B, 9B, 10B & 12B. PERMIT UNDER MASTER APPLICATION.<<<PC for power only. Scope of work includes new equipment  (VCU X01) and 4 new circuits in panel DP-644. Equipment is located in hazardaus location Class 1 Div 2. Note delta 8.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17904	12041-10000-04998	1615 N CAHUENGA BLVD	90028	13	148-5A187 277	5546007013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.10022	-118.32968	T.I. to an existing restaurant.  New lighting, receptacles, and load.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17905	10041-20003-15411	14731 W RAYEN ST	91402	7	195B149   247	2651012028	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Apartment			10/04/2011 12:00:00 AM	11/10/2011 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.23197	-118.45487	Plan check for revision Delta 6 to approved plans. Revision consists of service load calculation, addition of new optional stand-by generator, new ATS, new panel EM, and branch ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17906	19041-10000-03025	5790 W JEFFERSON BLVD	90016	10	120B173   842	4205031012	[Q]M1-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	12/05/2023 12:00:00 AM	ADDRESS	34.02643	-118.37606	TEMPORARY POWER FOR A NEW HIGH-RISE BUILDING AND PARKING GARAGE, SCOPE OF WORK INCLUDES NEW 800A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17907	15041-20000-07229	6320 N TOPANGA CANYON BLVD STE#G-1655	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.18578	-118.60536	Full plan check for power and energy. First time tenant for a space at the Topanga Canyon project. Total lighting area = 9,342 sq. ft. Installation of (1) tenant panelboard and associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17908	15041-10000-35837	11677 W SAN VICENTE BLVD STE-200	90049	11	132B145   497	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.05404	-118.46492	FULL PC, PER CUSTOMER'S REQUEST, TI TO AN (E) COMMERICAL RESTAURANT BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4160.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17909	18041-10001-01679	4333 W WILSHIRE BLVD	90010	4	132B189    17	5505029012	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.06197	-118.32252	Change to approved set by adding out door  modification in place located in a commercial building, Total are is 20,680 SQ FT. All permit fee is paid under original application number.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17910	18041-10000-25560	5220 W 102ND ST	90045	11	090B173   196	4129032010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	33.9435	-118.37122	PLAN CHECH FOR T24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17911	19041-10000-45880	7381 S LA TIJERA BLVD	90045	11	099B169    80	4104005901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	33.9708	-118.37942	PC FOR ENERGY ONLY FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 83425  SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17912	12041-10000-00164	12724 N DARLA AVE	91344	12	222B133   590	2602019045	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.30197	-118.50363	SFD Roof Mounted PV System, 9.310 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17913	16041-20001-33524	5700 S VERMONT AVE	90037	9	108B197  1257	5001013031	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM			PC Approved	01/06/2017 12:00:00 AM	ADDRESS	33.99028	-118.29128	01/06/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor parking lot lighting. Total lighting area = 34,422 sq. ft.*****Previous Work Description*****EXTERIOR LIGHTING UPGRADE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17914	14041-20000-01941	3989 S CENTINELA AVE	90066	11	111B157   656	4235018027	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	33.99985	-118.43088	New 800 amp service for an existing 8-unit tenant space.  Full Plan Check for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17915	16041-10000-12969	11150 W SANTA MONICA BLVD #850	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			PC Info Complete	04/14/2016 12:00:00 AM	ADDRESS	34.04704	-118.44563	T-24, PC FOR ENERGY ONLY. TI AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SUITE #850. TOTAL AFFECTED AREA IS 3840.5 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17916	14041-20000-08628	5450 W PICO BLVD UNIT 101	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.04862	-118.35714	TI for 750 sq. ft.  commercial shake shop.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17917	18041-10000-26188	20745 W NORDHOFF ST	91311	12	198B109   176	2748037008	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.23563	-118.5858	PLAN CHECH FOR TITLE 24 ONLY FOR CHANGE OF EXISTING HID FIXTURES TO NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17918	13041-10000-35204	3341 W 43RD PL	90008	10	114B185  1144	5024019902	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	11/20/2023 12:00:00 AM	ADDRESS	34.00441	-118.33097	ADDITION TO (E) BUILDING. FULL PLAN CHECK FOR POWER AND ENERGY TO THEATRE. NEW (3) 600A, 600A, 800A, 480V, 3PH, 4W SERVICE.  PROJECTED AREA IN LIGHTING WORK IS APPROX. 6892 SQ FT; TOTAL 2 STORY + BASEMENT.  FIRE ALARM PLAN WILL BE SEPARATED (NOT IN SCOPE OF WORK). VARIANCE for 3 Services (600A, 600A, 800A) was paid.VARIANCE for Fire Alarm was Paid. Building Permit: 13014-10000-05190 - B13LA15649 was Extended to 12/13/17	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17919	17041-10000-32016	14622 W VENTURA BLVD 107	91403	4	166-5A151 118	2276002066	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.15125	-118.45177	PLAN CHECK FOR T24 ONLY, TI-CHANGE OF USE FROM (E) RETAIL TO (N) BEAUTY PARLOR. 150A PANEL IS EXISTING. JUST ADD SOME NEW CIRCUITRY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17920	13041-10000-17637	12871 W RUNWAY ROAD Units 1-6	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/03/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	33.97499	-118.41991	PLAN CHECK POWER AND ENERGY FOR NEW 6-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #3  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17921	18041-20000-30730	8360 W MELROSE AVE #105	90048	5	141B173   498	5528016060	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.08338	-118.37235	Plan check for Title 24 Energy only in existing retail space T.I. Total area: 1255 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17922	13041-10000-00928	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	PLAN CHECK FOR POWER AND ENERGY. SITE WORK FOR LA DODGERS. PARKING LOT LIGHTS,  GOLF CART CHARGERS, SIGNS, RECEPTACLES ETC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17923	18041-20000-08073	8360 N ETON AVE	91304	3	192B105   528	2779013022	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.22124	-118.59493	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17924	18041-10000-42044	9228 N TUJUNGA AVE	91352	6	198B169   116	2538010002	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.2366	-118.38036	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17925	13041-10000-06846	1302 W 177TH ST BLDG A	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	PLAN CHECK FOR POWER AND ENERGY FOR A NEW THREE STORY 33-UNIT APARTMENT BUILDING (BUILDING A). SITE LOCATED IN METHANE ZONE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17926	15041-20000-42620	300 S SANTA FE AVE WALKWAY	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Expired	01/19/2018 12:00:00 AM	ADDRESS	34.04587	-118.23239	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MIXED USED COMMERCIAL AREA (ONE SANTA FE YARDS ENCHANTMENTS). SCOPE INCLUDES NEW DECORATIVE LIGHTS. TOTAL HARDSCAPE AREA IS 22,162 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17927	18041-10000-32239	1486 W COLORADO BLVD	90041	14	162A227   133	5690001003	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.13906	-118.19772	TI IN AN EXISTING OFFICE AREA. T-24 ENERGY ONLY.BLDG PERMIT: 18016-10000-22205	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17928	11041-10000-18084	10149 N RESEDA BLVD	91324	12	204B125   215	2729011004	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.2554	-118.5364	CHANGE OF USE FROM RETAIL TO DENTAL OFFICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17929	14041-20001-01893	4056 S MARCASEL AVE	90066	11	111B157   371	4233010006	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.00154	-118.42331	(((EXPEDITE FEES))))New UNGROUNDED rooftop PV system on an existing single family dwelling.  Existing 400 AMP Service size.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17930	10041-10000-12936	6317 W WILSHIRE BLVD	90048	5	135B177   468	5510028004	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Public Safety Only			07/07/2010 12:00:00 AM	07/07/2010 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.06368	-118.36592	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING FOR THE WILSHIRE HOTEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17931	15041-10000-03524	9721 N LURLINE AVE	91311	12	201B109   204	2748004048	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.24717	-118.58429	Title 24 plan check only.  Total area = 510 sq. ft.Retrofit existing lights to LED with retrofit kits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17932	17041-20000-45056	17068 W KNAPP ST	91325	12	198B133   411	2692020044	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Re-Activate Permit	03/30/2018 12:00:00 AM	ADDRESS	34.23825	-118.50515	Plan check for solar pv system w/roof-mounted array on SFD.Interconnecting with center-fed panel.7.6kW ungrounded system. (26) 330W pv modules.Each module has a 370W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17933	15041-10000-42886	1100 S HOPE ST C3	90015	14	127-5A207 333	5139005***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.04195	-118.2631	PC for energy only to a commercial building, existing highrise building. Unit C3. Change of use from retail to restaurant. Adding new lighting and power. Total Sq ft = 2565	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17934	18041-10000-03384	11133 W VANOWEN ST SUITE A	91605	2	183B173   182	2319005017	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.19409	-118.37363	REPLACE INDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17935	11041-20000-24451	22695 W CRESPI ST	91364	3	171B097   774	2075012023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.16333	-118.62102	New 7.35 KW DC roof mounted PV system for a single family residence.  Applicant is using microinverters.  A variance has been filed to use microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17936	17041-10000-08411	7312 W BEVERLY BLVD	90036	5	138B181   454	5512017002	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.07597	-118.34918	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 14,725 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17937	19041-10000-18850	1674 S CORINTH AVE	90025	11	126B149   116	4261009028	C2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	04/07/2021 12:00:00 AM	ADDRESS	34.045	-118.44844	Energy plan check for a tenant improvement to existing two story office building. Scope includes new lighting and equipment with a total lighting area of 2491-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17938	11041-10000-02297	"1452 W KNOX ST Bldg ""B"""	90501	15	057B193   126	7351003010	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM			PC Approved	02/15/2011 12:00:00 AM	ADDRESS	33.85386	-118.30152	ELECTRICAL WORK IN BUILDING B - HEALTH PRODUCTS MANUFACTURING FACILITY. AS-BUILT SET OF PLANSThis is to split thepermit to two phases.  The feeder to the equipment will terminate to J-box, and a new installer will connect the equipment. Note provided in regards to conductors to continue with same type and size from panel to equipment ((CHANGE OF ENGINEER ON ORIGINAL PLAN TO CONTRACTOR DSIGN BUILD, CROSS REFERENCE OLD WITH NEW 06041-10002-12747))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17939	18041-20001-48448	7521 W MULHOLLAND DR	90046	4	156B177   188	2427005037	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.12575	-118.35915	Expedite per applicant request Plan check for PV roof mounted system, sytem size:19.8kW DC, 17.1kW AC, with 60 microinverters and 60 PV Modules connected to 600A existing Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17940	12041-10000-19994	505 S SAN PEDRO ST 1-108	90013	9	127-5A213 232	5148012019	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			08/23/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.04392	-118.24444	Fire alarm for a new apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17941	11041-10000-18730	12920 S FIGUEROA ST	90061	15	081B201   316	6132015054	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	33.91479	-118.28252	TI IN AN EXISTING COMMERCIAL SPACE. PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17942	19041-10000-43982	9400 N LURLINE AVE	91311	12	198B109   207	2748041035	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM			PC Info Complete	12/03/2020 12:00:00 AM	ADDRESS	34.24106	-118.58397	(Assign to Edwin or John per Mr. Nabil request)PV2. NEW 600A480/277 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD FOR A NEW PV COMMERCIAL PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17943	10041-20000-07433	14439 W BURBANK BLVD	91401	2	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	06/29/2010 12:00:00 AM	ADDRESS	34.17235	-118.44788	PLAN CHECK T-24 ENERGY FOR CHG OF USE TO YOGURT CAFE WITH SEATING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17944	18041-10000-45608	800 W OLYMPIC BLVD 150	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.04484	-118.26453	T-24 check only for an existing shaquille's resturant. 4194sf- unit #150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17945	19041-10000-16879	12621 W RYE ST	91604	2	165B161  1096	2362015900	OS-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	09/21/2023 12:00:00 AM		Issued	09/21/2023 12:00:00 AM	ADDRESS	34.15144	-118.40821	Full plan check for a NEW 1-STORY GYMNASIUM RECREATION BUILDING with (1) new 1200-Amp 120/208v 3phase 4-wire service. Scope includes new equipment with new lighting and equipment with a total area of 74,772 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17946	19041-10000-21081	1150 S OLIVE ST 10TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.03962	-118.26181	Full PC for 10th Floor of an office TI. Scope of work inclues instaling new panels and equipment. The affected area is 18762 SQFT. Three building numbers are given for the three floors.B#1: 19016-10000-12257 (9th floor)B#2: 19016-10000-12315  (26th floor)B#3: 19016-10000-12301 (10th floor)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17947	16041-10000-21917	11150 W SANTA MONICA BLVD 4th floor	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM			PC Info Complete	06/22/2016 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI to an (E) office space located on the 4th floor. New addition load < 400A, PC for T-24 only. Total area: 5,939 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17948	18041-20000-45095	331-335 S BROADWAY	90013	14	130-5A211 111	5149015018	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	03/15/2019 12:00:00 AM	ADDRESS	34.05037	-118.24893	New fire alarm system for 2-story renovated commercial building.  (62) devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17949	13041-10000-09614	6361 W WILSHIRE BLVD	90048	5	135B173   824	5510028008	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			PC Approved	04/15/2013 12:00:00 AM	ADDRESS	34.06384	-118.36734	remodeling of a Jeresy Maid  sandwich shopplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17950	15041-10001-08932	462 E COMMERCIAL ST	90012	14	130-5A215  46	5173001905	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			Reviewed by Supervisor	04/07/2015 12:00:00 AM	ADDRESS	34.05309	-118.23584	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. <<<PV2, INSTALL 46 KW AC ROOF-MOUNTED SOLAR ARRAY ON A BUS MAINTENANCE AND OPORATION FACILITIES OF PUBLIC WORK BLDS, TIE WITH 3000 A MAIN SERVICE PANEL. (2)INVERTERS 23 KW AND (168) MODULES.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17951	15041-10000-39027	9650 N DE SOTO AVE	91311	12	201B109   231	2748023034	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.24585	-118.58835	ADDITION OF SPRAY BOOTH. TI. PC FOR POWER AND ENERGY. GREATER THAN 400A NEW CONNECTED LOADS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17952	14041-10000-34558	5100 W WILSHIRE BLVD 1-138	90036	4	132B181    39	5507026001	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.06187	-118.34094	Power plan check for new 7 story 138 unit apartment building.  New 5000 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17953	17041-20000-07890	15742 W ARCHWOOD ST	91406	6	180B141   116	2233001026	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.19274	-118.47654	pv1install roof mounted pv system sized 3kw interconnected with msp.This system is an addition to an existing system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17954	18041-20000-28799	12704 W BRANFORD ST	91331	6	198B161    32	2629003029	(Q)MR1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	03/21/2022 12:00:00 AM	ADDRESS	34.24305	-118.41	Plan check for power and energy. Project site is an existing warehouse/office building. Project scope is a tenant improvement. Work includes a new 3,000 Amp service, new distribution equipment and loads, and a total lighting area of 102,939 sq. ft. New service will also refeed existing distribution equipment.Note: Building application has been generated under 18014-10000-04256	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17955	14041-10000-13607	10158 N BALBOA BLVD	91343	12	204B133   309	2685002026	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	PIN	34.2556262	-118.50116066	REMODELING OF A SALVATION ARMY STOREPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17956	15041-10000-01164	3221 W TEMPLE ST 1-67	90026	13	139-5A201 222	5156007015	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village		1958.02	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.07565	-118.28154	(N) fire alarm system for 3-story 67-unit apartment building with one level subterranean parking.  FACP with 191 devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17957	14041-20000-17527	9145 N BALCOM AVE	91325	12	198B129   363	2766004009	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.23745	-118.52169	PV1.  Install 6.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17958	17041-20001-41529	23317 W SCHOENBORN ST	91304	12	192B093   321	2005011011	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.22052	-118.63547	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (26) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17959	16041-10002-45157	13730 W VENTURA BLVD	91423	4	165B157   667	2266020004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.148	-118.43213	REVISIONS TO LIGHTING PLANS- OCCUPANCY SENSORSARE  REPLACED  WITH AUTOMATIC TIME CLOCK WITH OVERRIDE SWITCH; THREE LUMINAIRES WERE REMOVED; TITLE 24 COMPLIANCE FORMS WERE UPDATED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17960	18041-20000-34889	12936 W ADDISON ST	91423	4	168B161  1197	2358023023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	09/13/2023 12:00:00 AM	ADDRESS	34.16107	-118.41511	PV1.  Install 18.0 kW DC roof mounted grid tied PV system.  (60) modules with (2) 7.6 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17961	17041-10000-37865	780 S GLADYS AVE	90021	14	124-5A213 156	5146002040	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.03642	-118.24562	TITLE 24 ONLY, RELACE INDOOR HID FIXURES WITH NEW LED FIXURES, TOTAL SQUARE FOOTAGE 6275 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17962	16041-10000-17698	7816 N SIMPSON AVE	91605	6	189B169   604	2310025031	R4-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Public Safety Only			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Closed	02/07/2017 12:00:00 AM	ADDRESS	34.21268	-118.38874	NEW FIRE WARNING SYSTEM IN MIXES USED BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17963	19041-10000-08017	301-445 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	12/19/2022 12:00:00 AM	ADDRESS	33.77206	-118.27885	Power plan check for a 277/480 voltage 1600-amp service equipment system  Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application # 19041-10000-08003	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17964	18041-20000-47832	21700 W OXNARD ST Ste 830-840	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.17901	-118.60179	Tenant improvement to two (E) adjacent highrise commercial office suites.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17965	12041-10000-05915	7083 W HOLLYWOOD BLVD 5TH FLOOR	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	03/15/2012 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.10173	-118.34439	PLAN CHECK T24 ENERGY/EMERGENCY FOR INTERIOR TI ENTIRE 5TH FLOOR. PERMIT FOR NEW BRANCH CIRCUITS. EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17966	15041-20000-37233	1731 S WESTWOOD BLVD	90024	5	129B153   302	4324028047	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.05138	-118.43868	TI to existing commercial building (beauty salon). Plan check for energy only. Adding new lighting. Total sqft. 906.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17967	15041-10000-33947	1061 W VIA NAVARRA	90732	15	021B193   114	7445019069	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	33.75412	-118.30117	PV1, ROOF MOUNTED SOLAR SYSTEM (34) MODELS AND (1) INVERTERS PRIMO 7.6. (34) KYOCERA #KU2656ZPA (1) FRONIUS #PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17968	13041-10000-09489	11831 W VOSE ST	91605	6	183B169   185	2321004004	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.19855	-118.39129	CONDUIT ONLY PERMIT AND GROUND. VARIANCE ON FILE. IN REFERENCE TO APPLICATION NUMBER 12041-20001-23469.*************************************************12041-20001-23469 DESCRIPTION: Changes to previously approved set of plans. 3000A 480 3-phase service changed to a 800A 3-phase delta service. Changes to voltage drops and fault current, all equipment inside building is the same as previously approved. NEW WAREHOUSE / OFFICE BLDG -	N	N	Express Permit	06/10/2024 12:00:00 AM
17969	15041-10000-05826	5722 S RUTHELEN ST	90062	8	108B193  1137	5005023008	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	33.99029	-118.31246	PV1.  Install 6.375 kW roof-mounted PV system.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17970	13041-10000-34016	8672 N LINDLEY AVE	91325	12	195B125   862	2787001021	(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.22832	-118.52715	TITLE 24 PART 6 ENERGY; TI IS FOR 'SUBWAY' TO EXISTING SINGLE STORY BUILDING. NO CHANGE OF USE, EXISTING SANDWICH SHOP. PROJECTED AREA IN SCOPE OF WORK IS APPROXIMATELY 1160 SQ FT. E-PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER. SCOPE OF WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17971	14041-20000-31405	17270 W COMMUNITY ST	91325	12	192B133   217	2690017111	RE11-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.22226	-118.50956	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING 20 MODULES. USING ENPHASE M250. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17972	13041-10000-29664	5413 W ADAMS BLVD	90016	10	123B177   934	5043001009	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.03263	-118.36069	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO EXISTING BUILDING. CHANGE OF USE TO RESTAURANT. NEW 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17973	19041-20000-14606	2208 S DUXBURY CIR	90034	5	126B165   295	4309014005	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	01/19/2021 12:00:00 AM	ADDRESS	34.04332	-118.39625	PV1.  Install 15.1876 kW AC / 17.020 kW DC roof mounted grid tied PV system.  (46) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17974	18041-10000-14862	1346 W COURT ST	90026	1	135A209   177	5160011010	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			04/30/2018 12:00:00 AM			PC Info Complete	06/06/2018 12:00:00 AM	ADDRESS	34.06444	-118.25789	New Methane detectin System, on a new 4 story with 2 subterrenean levels 43 unit apartment. Install 28 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17975	15041-10000-27392	7515 W SUNSET BLVD	90046	4	147B177   984	5550010021	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.0982	-118.35335	TI - T24 on a juice bar. 1078 sq.ft PC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17976	18041-20000-21442	1468 N KINGS ROAD	90069	4	147B173   381	5555019006	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.09749	-118.37305	Plan check for PV battery back up system, system size:15.2kWac with 23 modules, 2 inverters(7.6kW), 2 9.8kWh LG Chem.  connected to 200A Service with derate main breaker.Fees $32.05 due to California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
17977	16041-10001-23815	3200 W ADAMS BLVD	90018	10	123B189   714	5052015032	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM			PC Approved	10/13/2016 12:00:00 AM	ADDRESS	34.03243	-118.31875	Reduction in scope of work.  Plan check and permit to cover gym building only, seperate permit will be filed at another time for the annex building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17978	16041-10001-16755	8250 N WOODMAN AVE	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.22107	-118.43251	Installation of new roof mounted solar PV array on existing Kaiser Foundation medical office building.  Total system size = 317 kWac.  11 SCA23KTL inverters, 1 SCA28KTL inverter, and 1 SCA36KTL inverter.  1,231 Hyundai HIS-S325TI modules.  Supply side tap used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17979	14041-20000-20456	8830 N WHITE OAK AVE	91325	12	195B129   575	2768013020	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.23147	-118.51984	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INT6ERCONNECTED WITH MSP.(21) TRINA SOLAR TSM255 MODULES(1) SOLAR EDGE SE5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17980	14041-10002-04735	1136 W 6TH ST	90017	1	132A207   615	5143024015	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Apartment			09/04/2015 12:00:00 AM			PC Info Complete	09/04/2015 12:00:00 AM	ADDRESS	34.05447	-118.26366	**9/4/15 Supplemental: Outdoor hardscape lighting. Total area: 2620 sq.ft((plan check for power and energy for an 42 unit adaptive reuse high-rise apartment building. new 800A underground service, not located in methane zone per zimas.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17981	16041-10000-44691	3666 N BARHAM BLVD (BUILDING-N)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.13915	-118.3414	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17982	17041-10000-28460	319 S CONCORD ST	90063	14	124-5A227 249	5179011027	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Issued	08/11/2017 12:00:00 AM	ADDRESS	34.03503	-118.19862	PV1 roof mounted system with (10) modules and (1) 3.8KW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17983	16041-10000-33067	6817 W FRANKLIN AVE	90028	4	150A185   287	5549018024	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Issued	10/28/2016 12:00:00 AM	ADDRESS	34.10427	-118.33904	PC for title 24. Energy onlyNew lights for high school play ground. Total area 3304 sq.ft (outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17984	11041-10000-21198	10000 W PICO BLVD BLDG 2	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00, 2691.00, 2695.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.05211	-118.40654	BLDG. NO. 2 (Womens room section inc. outside lighting) OF POOL HOUSE AT THE HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDG. NO. 1, 2, 3, & 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17985	19041-20000-15864	7132 W FOOTHILL BLVD	91042	7	202-5A199 597	2564001015	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			Corrections Issued	04/30/2019 12:00:00 AM	ADDRESS	34.24792	-118.28712	Plan  check for Title 24 only in retail tenant improvement. Total area: 2052 sq ft. B#18016-20000-22883	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17986	10041-20000-10335	7509 W SUNSET BLVD	90046	4	147B177   984	5550010021	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM			PC Approved	06/02/2010 12:00:00 AM	ADDRESS	34.0982	-118.35316	Revisions to 10041-20000-00207	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17987	14041-10000-27409	8308 S WESTLAWN AVE	90045	11	096B161    19	4112031019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	33.96305	-118.40712	Installation of roofmounted residential solar PV standard plan. # of inverters: 1. System size: 4.59kW. # of modules: 18.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17988	18041-10000-19642	2035 N HIGHLAND AVE	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.10759	-118.3376	UPGRADE SERVICE AND ADDED PANELBOARDS AND CKT, MAIN PERMIT FEES HAVE BEEN PAID FOR UNDER APPLICATION # 17041-10000-14251.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17989	18041-20000-44633	18050 W CHATSWORTH ST	91344	12	207B125   637	2731008023	C2-1L, C2-1VL, [Q]P-1	North Valley	Granada Hills - Knollwood	Granada Hills South, Sherman Oaks		1113.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.26455	-118.52561	Plan check for new fire alarm system for retail space Ross Dress For Less. Total fire alarm devices: 26 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17990	16041-10000-19872	1624 E 109TH ST	90059	15	088-5A213 217	6069009028	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	33.93672	-118.24541	PV1 rooftop solar 7.3kW AC system.   (34) KD255GX   (1) PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
17991	10041-20000-25466	6300 W ROMAINE ST	90038	4	144B185   960	5533020023	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.08878	-118.32903	New 6 stories  building with outdoor/indoor parking.  Tenant in first floor and top four floors are open wall parking.  New service, switchboard, subpanels, branch circuits, and indoor/outdoor lightings.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17992	17041-20000-25224	6100 N SEPULVEDA BLVD	91411	6	177B145   597	2242025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Issued	08/09/2017 12:00:00 AM	ADDRESS	34.18076	-118.46437	PLANCHECK FOR T24 ENERGY ONLY. COSTCO OUTDOOR LIGHTING. 390019 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17993	17041-10000-05071	476 W 43RD ST	90037	9	114A201   306	5019029001	C2-1VL	South Los Angeles	Southeast Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.00542	-118.28215	Plan check for Title 24 only in existing space remove outdoor metal halide fixtures and replace with new LED lighting fixtues. Total area: 7,875 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17994	12041-10001-13879	470 E SWINFORD ST	90731	15	021B201   230	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	33.74945	-118.2748	Suppl. application for additional fuel pump equipment at Catalina Express, Berth 95 at the port of LA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17995	17041-10000-42857	5870 S CRENSHAW BLVD	90043	8	105B185     9	4005005022	P-1, [Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	33.98771	-118.33052	PC FOR NEW FA SYSTEM IN A RETAIL SPACE. SCOPE INCLUDES 4 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17996	13041-10000-02902	380 W WORLD WAY Space 32	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Approved	02/05/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	T24 energy only per supervisorTI OF NEW RETAIL SPACE FOR LAX. THIS IS FOR SPACE # 32. RESTAURANT SPACE. TOTAL SQ FT OF 753.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
17997	18041-20001-47039	4513 N TOBIAS AVE	91403	4	168A149   195	2265004015	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	34.15355	-118.45214	Expedite per applicant request Plan check for PV roof mounted system, system size: 14.45kW, 13.127kW AC CECwith 49 PV modules and 1 inverter(11.4kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
17998	19041-20000-28544	14364 W VENTURA BLVD	91403	4	166-5A151 188	2266002054	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	PIN	34.1500734	-118.44574967	change of use from retail to dental office.  plan check for power only.  all existing lighting to remain.building application number 19016-20000-04980	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
17999	15041-20000-29703	11400 W CULVER BLVD	90230	11	111B161   400	4217015002	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			09/09/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	PIN	34.00072849	-118.41264563	New 800A service. Adding new lighting including emergency. Plan check for power and energy.Note: Building permit has been filed under application number 14010-20000-03622	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18000	15041-10000-21992	10979 W BLUFFSIDE DR	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	PC FOR POWER AND ENERGY. REMODELING OF MIXED USED APARTMENT BUILDING. TOTAL AREA 11000 SQ FT. ***PER APLICANT REQUEST FOR FEE ESTIMATION.***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18001	12041-20000-21607	4221 W WILSHIRE BLVD 300A	90010	4	132B189    20	5504001014	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM			PC Approved	09/12/2012 12:00:00 AM	ADDRESS	34.06194	-118.32113	Plan check for energy and emergency lighting. Commercial high-rise building. 5104 sqft. Suite 300A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18002	17041-10000-22486	1515 E 15TH ST	90021	14	121-5A213 395	5130019031	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.02483	-118.24354	Plan check for power only.  Replacement and addition of rooftop equipment on existing warehouse building.  New load > 400 amps. fault current calculations under Engineer (Lic #. 014055)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18003	18041-10000-47702	7636 N CAPISTRANO AVE	91304	12	186B101    69	2013015014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.20952	-118.61651	Plan check for a PV1 3.8KW AC  roofmounted system adding on to an existing PV system. Scope include (9) modules, (1) inverter and (1) subpanel interconnecting through the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18004	19041-20000-51699	1312 N SAN FERNANDO ROAD	91340	1	147A217   270	5454035023	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM			Reviewed by Supervisor	01/15/2020 12:00:00 AM	PIN	34.09610484	-118.23077691	Plan check for Power only, 800A Service with 2 new panel and existing load. Machinery load shll pull permit under separate permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18005	15041-10000-10898	2028 S BENTLEY AVE	90025	5	126B153   412	4323023033	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			04/13/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.04285	-118.43873	NEW 7 UNIT APARTMENT BUILDING. FULL PC FOR ENERGY AND POWER. FEES ESTIMATED PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18006	13041-10000-13904	4453-4461 N TUJUNGA AVE (11 Units)	91602	2	165B173   133	2365014012	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.15184	-118.37925	"pc for power and energy. new building. 2 typical units. customer brought check already. not a methane zone NEW  89'11"" X 95'8"" 11 UNIT THREE STORY  (V-B) APARTMENT OVER ONE LEVEL TYPE (V-B) BASEMENT GARAGE.  1 ""VERY LOW INCOME"" AFFORDABLE HOUSING UNIT PLUS 10 UNITS (BY RIGHT + DENSITY UNITS). townhouse exits directly into courtyard."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18007	19041-10000-48460	8106 N LOMA VERDE AVE	91304	3	189B109   178	2109005023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.21714	-118.58948	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYTEM SIZE IS 3.8KWac/5.4KWdc, SCOPE OF WORK IS 17 MODULES (REC320NP) WITH OPTIMZERS (SE P320), LEADING TO A CENTRAL INVERTER (SE3800) AND A NEW 60A LOAD CENTER , MAIN BREAKER HAS BEEN DERATED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18008	14041-10000-34565	3959 W WILSHIRE BLVD	90010	10	132B189    24	5504027020	C4-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.06186	-118.31337	Plan check for energyn title-24 for existing tenant for El Pollo Loco Store #5410 Sute# 1A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18009	18041-20000-45343	7401 N LANKERSHIM BLVD	91605	2	186B169   690	2317017002	(T)(Q)RAS4-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	03/29/2021 12:00:00 AM	ADDRESS	34.20485	-118.38824	Plan check for power and energy. Project site is a new 5-story, 108-unit mixed use building. Building is 4 levels of residential over 1 level of commercial/parking over 1 level of basement parking garage. Work includes a 3,000 amp service and a total lighting area of 98,580 sq. ft.Note: Building application has been generated under 17010-20000-02985	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18010	13041-10000-26102	380 WORLD WAY #T-36R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of led sel-illuminated signs on the external walls of a the tenant space Michael Kors on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18011	17041-10000-40569	738 S UNION AVE	90017	1	130-5A205  92	5142023012	R4-1	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Issued	11/09/2017 12:00:00 AM	ADDRESS	34.05284	-118.27164	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18012	17041-10000-44138	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	Plan check for hazardous location in existing refinery for New Amonia Skid replacement exising  air blower and NSH vaporizer herater. Hazardous location Class I Div I. All new work is clouded, everything else existing to remain. Building Permit Number: 17020-10000-03271	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18013	16041-20000-26321	7654 N TAMPA AVE	91335	3	186B117    46	2104012038	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.20985	-118.55333	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222Plan check for PV2 roof mounted system. System size: 70kW with 2 inverters(15kW), 2 inverter(20kW) with 202 modules connected to MSP1 and MSP2	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18014	14041-20000-11722	3205 N WASHINGTON BLVD	90292	11	108B149  1325	4229005044	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	33.9898	-118.4487	T.I AND ADDITION TO EXISTING SPAE. CHANGE OF USE TO NEW RESTAURANT. PC FOR PLACE OF ASSEMBLY. RELOCATED 400A SERVICE. ENTIRE NEW ELECTRICAL SYSTEM. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18015	16041-10000-37382	4690 W COLORADO BLVD	90039	13	162B201    75	5593018013	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.14012	-118.27542	PC FOR POWER ONLY. SCOPE INCLUDES NEW 1200A  SWITCH BOARD INSTALLATION FOR CHILLER UNIT ( 277/480V) .NO OTHER EQUIPMENT TO BE CONNECTED UNDER THIS APPL.***********************************************************************************REF HVAC APP 16044-20000-11351	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18016	18041-10000-19752	20701 W SESNON BLVD	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	05/17/2024 12:00:00 AM	ADDRESS	34.29478	-118.58219	INSTALL LIGHTS IN PRIVATE ROADS FOR TRACK HOMES. EFFECTED AREA 120,000 SQR FT.PLAN CHECK FOR T-24 ENERGY ONLY. <<<FEE ESTIMATE ONLY>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18017	19041-20000-53651	5700 W 96TH ST	90045	11	093B169   169	4125024024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Info Complete	02/20/2020 12:00:00 AM	ADDRESS	33.94928	-118.38132	Plan check for power and energy for power and energy for 1600A 277/480Volts supply lighting load and power equipment. Lighting and power core and shell to the space. Total area: 48,497 sq ft. B#19016-30000-40822	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18018	15041-10001-39574	701 E 3RD ST 4TH FLR	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Expired	04/09/2018 12:00:00 AM	PIN	34.04581508	-118.23784015	"Changes on approved set marked as ""Field Revision Delta-1 and Delta-2"":Adding branch circuits, load changes on single line diagram and panel load schedule; However, it's still less than 400A.No changes on T-24 [Master plan was checked for T-24 only] <<Energy plan check for an office T.I. located in the 4th floor of a commerical building ; Scope includes new lighting and receptacles, total area is 11,356 SQ feet.>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18019	12041-20000-05195	1724 N HIGHLAND AVE 1-270	90028	13	148-5A185  63	5547011031	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	ADDRESS	34.10238	-118.3385	install 4 new panels only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18020	14041-10000-30573	1837 S SAWTELLE BLVD	90025	11	126B149   405	4261021008	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			11/04/2014 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.04291	-118.44567	Fire alarm variance not yet filed.New 5-story apartment, 19 units, with grade-level parking.  Plan check for power and energy.BLDG#14010-10000-03535. See additional comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18021	18041-10000-06574	7855 N HASKELL AVE	91406	6	189B141   158	2206002037	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	09/24/2021 12:00:00 AM	ADDRESS	34.21324	-118.47511	PC FOR POWER AND ENERGY FOR NEW 3 STORY SELF STORAGE BUILDING.NEW SERVICE RATED 600A 277/480 3PH SCOPE INCLUDES NEW PANELS, EQUIPEMENT, LIGHTS.  TOTAL AFFECTED AREA  152164 +47965 SQFT (200 129SQ FT indoor outdoor) B# 18010-10000-00755	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18022	11041-10000-09856	4050 S MARLTON AVE	90008	8	114B185   181	5032002049	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	09/23/2011 12:00:00 AM		Permit Finaled	12/14/2011 12:00:00 AM	ADDRESS	34.01133	-118.33847	title 24 energy for taco bell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18023	12041-20000-08707	611 W WILSHIRE BLVD #900	90017	14	129A209    82	5144005021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Approved	04/27/2012 12:00:00 AM	ADDRESS	34.04838	-118.25639	T.I. to existing high rise building on the 9th floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-08709	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18024	17041-20000-06310	20700 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	10/26/2021 12:00:00 AM	ADDRESS	34.29443	-118.58472	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18025	13041-20000-34740	5815 W SUNSET BLVD SUITE 105	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.09822	-118.31613	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK IN SUITE 105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18026	19041-20001-52442	3773 S DURANGO AVE	90034	5	120B165   382	4313021085	MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	11/24/2020 12:00:00 AM	ADDRESS	34.02717	-118.39401	Expedite per applicant request. Plan check for PV roof mounted system, PV system size: 86.9KW DC, 66.36KW AC with 220 PV Modules and 1 inverter(66.6KW) Supply side connection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18027	15041-20000-41914	9448 N TOPANGA CANYON BLVD	91311	12	198B101    79	2746013020	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Closed	07/30/2018 12:00:00 AM	ADDRESS	34.24211	-118.60602	PC FOR A NEW FIRE ALARM SYSTEM TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 1 FIRE ALARM PANEL, 1 COMMUNICATION PANEL,  AND 18 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18028	13041-10001-34430	1510 S CLOVERDALE AVE 1-5	90019	10	129B181  1223	5070014019	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.04617	-118.35222	Expedited RSES plan check per applicant request.{[[PV1, Install a 3.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) inverter(s)[SOLAREDGE # SE3800A-US] and (14) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house.]]}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18029	19041-20000-05420	1713 W 247TH ST PV1	90717	15	039B193   384	7372015054	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	33.80106	-118.30837	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW AC INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18030	17041-10000-30496	5251 W IMPERIAL HWY	90045	11	087B173   142	4129038001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	33.93108	-118.37125	Plan check for Title 24 only in existing space T.I. Total area: 5577 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18031	14041-20000-18520	7921 N ALDEA AVE	91406	6	189B133   581	2204011010	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.21415	-118.50838	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED TO MSP.(18) TRINA SOLAR TSM-255 MODULES(1) SOLAR EDGE PVI-5.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18032	16041-20000-09662	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	Plan check for power and energy. Project site is a tenant space within a new grocery store. Tenant space will be used as a restaurant. Total lighting area = 1,588 sq. ft.Note: Building application has been generated under 16016-30000-05508	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18033	19041-10000-10227	336-350 W 7TH ST	90731	15	015B201   165	7455012020	CM-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	11/30/2020 12:00:00 AM		Permit Finaled	05/24/2023 12:00:00 AM	ADDRESS	33.73797	-118.2843	POWER AND ENERGY PLAN CHECK INSTALL NEW 1600A 120/208V 3PHASE SERVICE. PROVIDE NEW PANELS, EQUIPMENTS AND LIGHTS. TOTAL AFFECTED AREA IS 30,842 S.F.B#18010-1000-01769	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18034	13041-10000-08538	13751 W HUBBARD ST	91342	7	222B153   124	2509014093	QR3-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.30578	-118.43247	Aditiion of 2490 SF for recreation room to existing 6-units apartment.  Original plans submitted under 13041-10000-02057.  Due to major changes from the original unapproved submital, a new submittal application is created.  Major changes include upgrade service from 600A to 800A.  New main panels, circuits, and energy.  Plan check for power and energy.Note: portion of plan check fee paid under previous submital.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18035	14041-10000-17509	5428 N FIGUEROA ST	90042	1	151-5A227 354	5468014028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	34.10766	-118.19633	PLAN CHECK FOR POWER AND ENERGY FOR 1000A SERVICE UPGRADE AND OF EXISTING 2 STORY MEDICAL OFFICE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18036	14041-20000-04582	824 E 17TH ST	90021	14	121-5A211 190	5131001047	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.02736	-118.25302	"PLAN CHECK FOR POWER AND ENERGY FOR A RETAIL WAREHOUSE; INSTALLATION OF NEW 400A, 480V, 3PH, 3WIRE SERVICE. NEW 225KVA 480V - 120/208V 3PH 4 WIRE DELTA WYE CONNECTED DRY-TYPE TRANSFORMER FEEDING NEW 800A DISTRIBUTION BOARD ""DB"" . PROJECTED AREA IN LIGHTING WORK IS APPROX. 6400 SQ FT. NOTE: LTG COMPLIANCE FORM MISSING ON PLAN, NO FAULT CURRENT REPORT FROM LADWP. ALSO, AREA IS PROJECTED IN CRA AREA AND REQUIRES CRA CLEARANCE PRIOR TO APPROVAL. IT IS AT THE PLAN CHECKER'S DISCRETION TO DETERMINE IF THIS CRA CLEARANCE IS APPLICABLE & MANDATORY"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18037	18041-10000-15274	500 S VIRGIL AVE SUITE #502	90020	13	135A201    62	5077005030	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.06492	-118.28687	EPC FOR POWER AND ENERGY FOR A TI IN MEDICAL SPACE FOR OUTPATIENT INFUSION ONCOLOGY  CENTER IN SUITE #502 ON THE 4TH FLOOR. TOTAL AFFECTED BLDG PERMIT# 18016-10000-09961	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18038	12041-10000-27614	10800 W PICO BLVD	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.04054	-118.4272	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS ON ATENANT IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18039	19041-10000-00332	4408 E WORTH ST	90063	14	135A229   166	5224005014	M3-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.06245	-118.18956	Energy plan check for removing HID fixtures and replace with new LED fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18040	12041-20000-23781	19154 W ENADIA WAY	91335	3	183B121   236	2129003001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1325.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.20002	-118.551	plan check solar installation. transformerless inverter (POWER-ONE). 4.41 KW DC, 3.78 CEC AC roof mounted solar electric system without energy storage components	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18041	13041-10001-03079	657 W REDONDO BEACH BLVD 1-6	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	33.89279	-118.28709	REVISED PERMITTED SET OF PLANS TO ADD A 75KVA XFMR,A 100A PANELBOARD AND 3 CIRCUITS IN EMPTY TENANT SPACE # 101(((((((((((CHANGE OF USE FROM PREVIOUS OPEN OFFICE SPACE TO NEW 6 TENANT RETAIL AND RESTARAUNT USE. RECONSTRUCTION OF ONE BUILDING TO 6 INDIVIDUAL TENANTS. SCOPE OF WORK INCLUDES PC FOR POWER FOR THE UNITS AND ENERGY FOR 1 OF THE UNITS. PER SUPERVISOR REQUEST, BACK ROOM PLAN CHECK REQUIRED. PC FOR ENERGY TOTAL OF 1177 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18042	15041-20002-13990	6121 W SUNSET BLVD	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM			PC Approved	09/15/2015 12:00:00 AM	ADDRESS	34.09818	-118.32309	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE PHOTOMETRIC FLOOR PLAN FOR EGRESS. REVISION OF PANEL SCHEDULES AND FLOOR PLANS DUE TO KITCHEN REVISIONS. RESTAMP NEW SET. PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18043	16041-10000-38595	1000 E WASHINGTON BLVD	90021	9	121-5A211 373	5131008048	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.0256	-118.2533	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR LIGHTING). TOTAL AREA 60450 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18044	16041-10000-08550	200 N SPRING ST 19TH FL &-21ST FL	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.05405	-118.24317	TENANT IMPROVEMENT ON 19TH AND 21ST FLOORS OF LA CITY HALLTITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18045	19041-30001-38390	4751 W WILSHIRE BLVD Suite 310	90010	4	135B185   565	5505001021	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Issued	10/22/2019 12:00:00 AM	ADDRESS	34.06219	-118.3337	T-24 plan check only, Changes to an approved set of plans. Changes include the revision of lighting and to correct plans per field installed scope of work. _______________________________________________________________________________Plan check for energy only, Interior, non-structural tenant improvement to the 3rd floor of (E) office building Scope of work includes new lighting and receptacles. Total sq. ft. 5547.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18046	11041-20000-21605	104 S ROBERTSON BLVD	90048	5	138B169   373	4334005002	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.07505	-118.3836	TI - retail P/C is for Energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18047	17041-10000-10740	10250 W SANTA MONICA BLVD KIOSK-#9175	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""Randy's Donuts"" Kiosk #9175.  Total area: 282sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18048	18041-10000-34769	515 S STANFORD AVE	90013	14	127-5A213 446	5147021025	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.04227	-118.24168	REPLACE 2X4 FLUORESCENT WITH LED RETROFIT-KIT. REMOVE INDOOR HID FIXTURE AND REPLACE WITH NEW LED FIXTURES.T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18049	17041-20000-39520	12800 W WENTWORTH ST	91331	6	198B161   395	2629027***	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.23659	-118.41161	"Plan check for power only. Replacing existing vandalized main distribution board (2000A 277/480V 3ph 4w).All loads future. AIC rating to match existing service equipment (65kAIC). ""COMPLY WITH DEPARTMENT ORDER effective date10/27/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18050	10041-20000-22251	4405 N VANALDEN AVE	91356	3	165B117   162	2178021013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	12/07/2010 12:00:00 AM	ADDRESS	34.15031	-118.55544	ROOF MOUNTED PHOTOVOLTAIC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18051	19041-20000-36746	5727 N CANOGA AVE BLDG 10	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	ADDRESS	34.17529	-118.5978	PV2 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING APARTMENT BUILDING #10. SYSTEM SIZE IS 11.8 KW DC/10.814 KW CEC AC. SCOPE OF WORK CONSISTS OF (33) PV MODULES, A 100A PANEL, AND (2) 5 KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18052	15041-10000-34775	5402 N FALLBROOK AVE	91367	3	171B097   115	2040027024	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.16851	-118.62308	PV1, INSTALL 10.40 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(40) MODULES: TRINA TSM-260 PA05A(1) INVERTER: FRONIUS PRIMO 8.2-A 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18053	15041-10001-24072	1500 W PACIFIC COAST HWY Bldg K	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION OF 54 DEVICES AND 1 POWER SUPPLIES, FOR FUTURE ADA REQUIREMENT.  (((NEW FA SYSTEM FOR A New 3-story, 20 unit apartment with garage, 53 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18054	19041-10000-53297	1250 N TOWER GROVE DR	90210	5	144B157   145	4356026004	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	10/04/2020 12:00:00 AM	ADDRESS	34.09352	-118.4241	[EPLAN] INSTALLING 3 NEW POWERWALL BATTERIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18055	17041-20001-08171	4300 N ARCOLA AVE	91602	4	165B177   697	2424023008	RE11-1-H-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM			PC Approved	04/19/2017 12:00:00 AM	ADDRESS	34.14805	-118.35489	expedite.pv1install roof mounted pv system sized 23kw interconnected with msp.This design is changes to an approved set 50% changes.  partial permit fees were paid under application number 15041-10000-22844.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18056	17041-30000-04024	6600 N TOPANGA CANYON BLVD #2093	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is a tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,031 sq. ft.Note: Building application has been generated under 17016-30000-02742	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18057	19041-10001-03880	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM			Corrections Issued	07/15/2019 12:00:00 AM	ADDRESS	34.08469	-118.4849	revision to an approved set , change under delta 2 and 3. change includes relocating some equipment as well as adding CU units.original scope:This is plan check for Power only, scope includes: Replacing a 450A service breaker to 600 Amp in an existing 600A service, Installing new HVAC system, new 75KVA transformer and new phase converter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18058	13041-20000-22074	3267 W OLYMPIC BLVD 1ST FLOOR	90006	10	129B193   228	5080008033	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	08/28/2013 12:00:00 AM	ADDRESS	34.05282	-118.30814	T24 FOR EXISTING BANK. TOTAL NEW LOAD 230A. PLAN CHECK FOR ENERGY ONLY. TOTAL SQRFT 8000. CONTRACTOR MAY BE DOING WORK ON OTHER FLOORS. INSPECTOR TO VERIFY TOTAL LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18059	13041-10000-24825	2920 W SUNSET BLVD	90026	13	142-5A203 430	5426020013	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	34.08317	-118.27382	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING FOR EXISTING OFFICE SPACE (TENANT IMPROVEMENT).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18060	13041-20000-28958	7325 N MEDICAL CENTER DR SUITE 101	91307	12	186B097   830	2021014040	(Q)CR-1VL, CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Issued	11/12/2013 12:00:00 AM	ADDRESS	34.20328	-118.62963	TI FOR EXISTING DR OFFICE. FULL PLAN CHECK REQUIRED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18061	14041-10000-32932	1223 W PACIFIC COAST HWY	90710	15	036B197  1115	7413003041	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	33.79009	-118.29876	Change of use from restaurant to medical office.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18062	18041-10000-20103	21240 W BURBANK BLVD BLDG 30	91367	3	174B105    40	2149016026	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Issued	07/19/2018 12:00:00 AM	ADDRESS	34.17307	-118.59314	PC FOR INTERIOR OFFICE TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 3060 SQ. FT. B#18016-10000-14144	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18063	18041-20000-41444	11700 W MAGNOLIA BLVD	91607	2	171B169   419	2355005061	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.1647	-118.38801	Plan check for new fire alarm system for 19 units multi-family building. New Fire alarm devices: 65  and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18064	18041-20001-28721	16253 W LOVETT PL	91436	5	165B137    71	2284015007	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	ADDRESS	34.15165	-118.48809	8/8/18changes to an approved set of plans.  changes to reduce number of modules to 69.this is plan check only.(((Plan check for a PV1 roof-mounted PV system. System size is 21.35 kWdc/18 kWac and consists of (3) inverters, (70) modules, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18065	15041-10001-23649	801 N FAIRFAX AVE #105	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.08567	-118.36172	T-24, TI TO A COMMERCIAL BUILDING, FISH MARKET. PC FOR ENERGY ONLY. TOTAL AREA 1000 SQ FT *FEES WERE PAID UNDER MASTER EXPRESS PERMIT, 15041-10001-23649.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18066	14041-10000-27055	5326 N LOLETA AVE	90041	14	163-5A227  30	5691001011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.14422	-118.19801	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD CENTRAL INVERTER PLAN. SYSTEM SIZE: 6000 KW. (24) KYOCERA KD 255GX(1) SOLAR EDGE SE6000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18067	17041-10000-35610	825 E BROOKS AVE	90291	11	111B145  1077	4239006007	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	33.99825	-118.46392	PC for one 13.5kWh, 5.8KVA Tesla AC Powerwall and new load center.16041-90000-34304	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18068	19041-10000-15202	3501 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.02194	-118.28455	INSTALLATION OF NEW MECHANICAL UNIT ON THE ROOF AND OUTDOOR LIGHTING. PLAN CHECK FOR POWER AND ENERGY.BULDING PERMIT: 19016-10000-11735	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18069	16041-10000-12311	9860 N SEPULVEDA BLVD	91343	7	201B145   228	2656005163	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.24959	-118.46718	T-24, COMMERCIAL INTERIOR ALTERATION AS WELL AS OUTDOOR ALTERATIONS TO LIGHTING. TOTAL SQ. FT. 2036	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18070	14041-20000-29653	211 S LA BREA AVE	90036	5	138B181  1307	5513022012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Closed	02/23/2016 12:00:00 AM	ADDRESS	34.07066	-118.34433	Plan check for energy only. New building, furniture retail space. Check lighting design to meet 2008 CA Energy Code standards (building permit submittal pre-July 1st, 2014). Indoor: 2,377sqft. Outdoor: 2,495sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18071	15041-10000-09206	432 S SAN VICENTE BLVD	90048	5	138B173  1162	5511044013	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Expired	04/27/2017 12:00:00 AM	ADDRESS	34.07067	-118.37575	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1684.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18072	19041-10000-32469	1749 S ORANGE GROVE AVE	90019	10	126B173   227	5066019028	R1R3-RG	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.04416	-118.36773	PV1, new rooftop mounted system, system size is 5.61KWdc/ 5KWac. Scope of work is 17 modules (Panasonic N330) with optimzers (SE P400), and a central inverter (SE5000H-US). Note: Panel upgrade is pulled under serpate permit	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18073	18041-10000-21801	176 N CITRUS AVE	90036	5	138B185   122	5513007002	R1V3-RG	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.07586	-118.33954	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.52KWdc / 10.24KWac.(32)AC MODULES- SPR-X22-360-D-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18074	17041-10000-22488	5717 N FAIR AVE	91601	2	174B173   561	2337032025	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Apartment			07/05/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.17449	-118.37469	PC FOR FA  IN A MULTI FAMILY (6 UNITS). TOTAL DEVICE COUNT 25  AND ONE FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18075	15041-20001-17245	14822 W LEADWELL ST	91405	6	186B149   664	2218020018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM			PC Approved	06/06/2015 12:00:00 AM	ADDRESS	34.20381	-118.45606	EXEPDITE PER APPLICANT REQUEST[Plan check for a PV1 roof-mounted PV system. System was an existing 3 kWac and a 3 kWac addition will be made, for a total system size of 6 kWac. System addition consists of (1) inverter, (12) modules, and (1) load center. Standard plan is not being used.Note: Original 3 kWac system was permitted under 11041-20000-24568]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18076	11041-20000-17608	6100 W WILSHIRE BLVD frst floor	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM			PC Approved	08/18/2011 12:00:00 AM	ADDRESS	34.06282	-118.36187	TI in an existing commercial BLDG. EPC is for T24. (Bug Music)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18077	19041-20000-13811	19620 W HART ST	91335	3	183B117   568	2130008002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.1973	-118.56075	INSTALLING A ROOFTOP PV SYSTEM TO EXISTING SFD TO FEED AN ADU. SYSTEM SIZE IS 2.17KW DC/1.68KW AC/1.93KW AC CEC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES AND (7) ENPHASE IQ6 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18078	19041-20000-38696	5515 E ASH ST 1-22	90042	1	153A227   338	5469029033	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1835.20	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Issued	10/08/2019 12:00:00 AM	ADDRESS	34.11168	-118.19708	NEW 600 AMP SERVICE FOR 21 UNIT MULTIFAMILY BUILDING AND REPLACEMENT OF SUBPANELS, WITH NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18079	18041-20000-00401	2426 E WASHINGTON BLVD OFFICE	90021	14	118-5A217 128	5168012020	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Info Complete	04/25/2018 12:00:00 AM	ADDRESS	34.01867	-118.22934	TI to (E) 2-story office building.  New 800A 240/120V 3ph-4w service supplying two separate buildings plus site.  Permit for shop under 18041-20000-00404.  ( inspector to verify emergency fixture A and H for UL924)Building permit for 2-story office under 18016-20000-00230.Building permit for shop under 18016-20000-00264.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18080	15041-10001-14255	13513 W CORNELIUS ST	91331	7	213B157   672	2523022024	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	34.2775	-118.42696	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.7KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18081	16041-20000-05414	11831 W FOLKSTONE LANE	90077	5	153B141   114	4378037079	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.1153	-118.47509	Install a solar array on a SFD. System size: 12.5 kWac, ungrounded system. (45) EnPhase M250 microinverters with (45) 285W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18082	16041-20000-19951	10537 W SANTA MONICA BLVD 2nd Floor	90025	5	132B157   951	4326033041	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.05512	-118.42802	TI to (E) commercial office space and restoration of fire-damaged equipment for the second floor and roof HVAC.  Plan check for energy.  6400 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18083	18041-10000-07543	7606 N FALLBROOK AVE Unit #15	91304	12	186B097   194	2013008054	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	34.20847	-118.6232	Engery plan check for a commercial T.I. Permit fee is paid under 17041-40001-25178. Total area is 293-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18084	13041-10001-22548	603 N BONHILL ROAD PV 1	90049	11	135B141   151	4494014028	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2013 12:00:00 AM			Corrections Issued	09/27/2013 12:00:00 AM	ADDRESS	34.06876	-118.48142	Change of inverter from transformered to transformerless - plan check only.  1 inverter: Power One Aurora PVI-6000-OUTD-US.  28 modules: Canadian Solar CS6P-250PX(((INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.  SYSTEM SIZE: 7 KW   INVERTER SIZE:  6 KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18085	13041-10000-29836	116 S ROBERTSON BLVD	90048	5	138B169   408	4334005005	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.07475	-118.3836	T24 PART 6 ENERGY ONLY. RETAIL STORE. NO CHANGE IN OCCUPANCY.  1317 SQFT. EMERGENCY LIGHTING. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18086	19041-10000-26332	740 S BROADWAY	90014	14	127-5A209 107	5144015023	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	03/13/2020 12:00:00 AM		Permit Finaled	07/23/2021 12:00:00 AM	ADDRESS	34.04414	-118.25412	FULL PLAN CHECK (POWER AND ENERGY) FOR 8 FLOOR OF A HIGH-RISE FROM FLOOR 2 TO 9. FIRST TIME TENANT. SERVICE SIZE IS 1000A, 277/480V, 3PH, 4 WIRE.  AREA OF SCOPE: 30,140 SQFT.BUILDING PERMIT# : 18016-10000-06163BUILDING PERMIT# : 18016-10003-06163	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18087	16041-10000-21755	1641 N IVAR AVE	90028	13	148-5A187 207	5546008022	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.10097	-118.3283	FA SYSTEM WITH 83 DEVICES, POWER PANEL, AND 2 CONTROL PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18088	19041-20000-28084	20330 W VIA URBINO pv1	91326	12	219B113   231	2701060025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.29912	-118.57686	Plan check for a 6KW AC / 6.6KW DC roofmounted system with (1) inverter, (20) modules and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18089	17041-20000-00660	3939 N LONGRIDGE AVE	91423	4	162B157   399	2385006008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.14162	-118.42054	"""0$ permit fees due to senate bill 1222""pv1install roof mounted pv system sized 15kw interconnected with msp."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18090	15041-10000-04265	19815 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	33.85108	-118.28825	Plan check for T-24. Remove HID light fixtures and replace with LED fixtues. Total area: 1812 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18091	17041-10001-44200	13832 W MULHOLLAND DR	90210	5	159B153   194	4385021023	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	34.13091	-118.43355	NEW 18KW WITH 50 PANELS, PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18092	14041-20000-19824	8843 N NESTLE AVE	91325	12	195B125   534	2769022028	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.23127	-118.53124	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(31) TRINA SOLAR TSM-255 MODULES(1) SOLAR EDGE SE6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18093	15041-10001-31864	6430 W SUNSET BLVD 1ST FLOOR	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.09782	-118.32979	1/20/2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1. (((Energy plan check for a change of use from office to coffee shop; Scope includes new lighting, receptalce, and equipment; Total area is 1994-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18094	19041-20000-32057	20801 W ACORN CIR UNIT #163	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	34.29449	-118.5866	PV1.  Install 3.15 kW roof mounted PV system.  (9) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18095	12041-20000-13979	1803 S PONTIUS AVE	90025	5	126B153    53	4323026007	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM			PC Approved	06/15/2012 12:00:00 AM	ADDRESS	34.04541	-118.44332	T-24 and emergency lighting plan check for remodeled space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18096	16041-20000-08066	5815 W SUNSET BLVD 201	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.09822	-118.31613	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR OFFICES. 2ND FLOOR. SUITE 201	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18097	16041-10000-41377	1910 E WASHINGTON BLVD	90021	14	118-5A215  25	5167005018	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.01961	-118.2388	REMOVE HID FIXTURE AND REPLACE WITH NEW LED FIXTURE. TITLE 24 ONLY. SQFT=77252.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18098	16041-10000-04814	2133 E VIOLET ST BLDG.B	90021	14	123A217    34	5166003010	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			Re-Activate Permit	05/10/2018 12:00:00 AM	ADDRESS	34.03269	-118.22873	FULL PC FOR A NEW 2 STORY CREATIVE OFFICE BUILDING (BLDG B). SCOPE INCLUDES NEW 1200A 120/208V 3PHASE, 4 WIRE SERVICE FEEDING TWO OTHER BUILDINGS; A & C.  BUILDING 2 OF 3. TOTAL AFFECTED AREA IS 49609 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18099	15041-20000-22280	3527 N ALANA DR	91403	5	159B141   129	2280022032	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.13507	-118.48085	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (32) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18100	19041-10000-44500	2264 N TALMADGE ST	90027	4	150B201   151	5591004019	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.11073	-118.28165	PV1. NEW ROOFTOP SOLAR MOUNTED SYSTEM. SYSTEM SIZE IS 9.1KW DC/ 7.6KW AC. SCOPE OF WORK INCLUDES 22 AC MODULES (SUNPOWER SPR-A415-GAC) AND PV 100 A SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18101	16041-10000-05450	3183 W WILSHIRE BLVD PLAZA LV	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.06196	-118.29111	T24 FOR EXISTING MIXED USE BUILDING IN THE COURTYARD AREA. Total hardscape area is 20,815 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18102	14041-20000-10286	2835 S ROBERTSON BLVD	90034	5	123B169   257	4301004024	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM			PC Approved	04/18/2014 12:00:00 AM	ADDRESS	34.03617	-118.38914	PLAN CHECK ONLY FOR T24 ENERGY. NO CHANGE IN OCCUPANCY. TI FOR KITCHEN. 1750 SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 14041-30000-07289.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18103	14041-10000-28008	11150 W SANTA MONICA BLVD SUITE 1670	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. 2453 SQFT, EMERGENCY LIGHITNG. SUITE 1670.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18104	16041-10000-18434	724 S ALAMEDA ST	90021	14	123A215   244	5166032030	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.0325	-118.23853	PC for T-24 only.  Remove HID fixtures and replace with new LED fixtures. Total atea: 11,375 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18105	13041-20000-22940	10070 W MCBROOM ST	91040	7	207B181   108	2543009024	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Closed	01/15/2014 12:00:00 AM	ADDRESS	34.26297	-118.35	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.5 KW USING 34 MODULES. USING ENPHASE MICROINVERTERS. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18106	19041-20000-46699	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM			Reviewed by Supervisor	12/10/2019 12:00:00 AM	ADDRESS	34.23162	-118.58832	PLAN CHECK FOR POWER FOR A NEW CONSTRUCTION TRAILER. TOTAL CONNECTED LOAD OVER 400 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18107	12041-20000-26092	21700 W OXNARD ST 1st floor	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM	01/10/2013 12:00:00 AM		Permit Closed	02/12/2013 12:00:00 AM	ADDRESS	34.17901	-118.60179	Change to lighting and receptacles in an existing office building on the 1st floor of a high-rise.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Load is 161 amps, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18108	17041-10000-05067	4709 W PICO BLVD	90019	10	129B185   936	5083025019	C4-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.04873	-118.33857	T-24, PC FOR ENERGY ONLY. REPLACE HID FIXTURES WITH NEW LEDs FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 12775 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18109	13041-10000-03146	4610 S HOOPER AVE	90011	9	112-5A211 250	5107011013	RD2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10, 2287.20	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.00182	-118.25199	Installing new fire alarm system for two story church.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18110	18041-20001-16531	7600 N BALBOA BLVD #203	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Revisions to approved set.  SLD changed to reflect (N) panel with (N) feeder.  (((Plan check for first time tenant retail space new lighting and receptacle. Total area: 862 sq ft.B#18016-10000-13841)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18111	17041-10000-42130	5318 S CRENSHAW BLVD	90043	8	108B185   196	5006007005	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	33.99429	-118.33044	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18112	14041-20001-05400	7233 N JAMIESON AVE	91335	3	186B129  1278	2121010009	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.2023	-118.52199	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18113	17041-10001-06056	11840 W SANTA MONICA BLVD	90025	11	126B149   487	4262005047	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Closed	02/06/2020 12:00:00 AM	PIN	34.04222127	-118.45848597	DELTAS 4, 5, 6, 7, 8, 9, 11, 12, 13, 16, 17, 18, 20, 21, 22, 25 CHANGES TO AN APPROVED SET. SCOPE INCLUDES CHANGES TO POWER AND ENERGY PLANS, 2 NEW PANELS, NEW 75K TRANSFORMER, EQUIPMENT, LIGHTING AND RECEPTACLES.  TOTAL AFFECTED AREA IS 30006 SQ.FTB# 17016-30000-04144**** ORIGINAL SCOPE****(FULL PC FOR POWER AND ENERGY. TI FOR A NEW TARGET RETAIL STORE. SCOPE INCLUDES A NEW 800A  120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 30006 SQ/ FT. )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18114	15041-10000-17833	1040 S GLENDON AVE	90024	5	132B153  1096	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.0617	-118.44407	PC FOR ENERGY, RELOCATION OF OFFICE TO AN EXISTING  TENANTSPACE. TOTAL AREA 2540 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18115	19041-10000-36914	317 E 42ND PL	90011	9	114A205   191	5113021013	R2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2283.20	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.0067	-118.27011	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 14 MODULES (Q-PEAK 305), 14 OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTER (SE3800H-US). SYSTEM SIZE IS 4.27KWdc AND 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18116	13041-10000-26472	512 N CASCADA WAY	90049	5	141B145   350	4369015006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.08031	-118.46142	plans lost so plan check only for 13041-10000-11873. new description:PV1 4.32KWAC 240V MICROINV 1STORY. nonSTD. ROOFMOUNT.[( 20) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: EHS3 250]old description:PV1 MICRO INVERTER SINGLE STORY HOUSE. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE:EH53-250} 20 modules]. STANDARD PLAN ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18117	15041-10000-06994	12704 W FILMORE ST	91331	7	213B161   519	2532018022	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Expired	04/04/2017 12:00:00 AM	ADDRESS	34.28037	-118.40945	PV1.  Install 2.616 kW roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18118	16041-10000-05798	900 N ALAMEDA ST CR3	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR 2 POWER  DISTRIBUTION UNITS FOR NEW COMPUTER ROOM. 3. EACH DIST. UNIT IS 300KVA, 4 PANELS WITH NO CONNECTED LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18119	19041-10000-27606	904 S NORMANDIE AVE	90006	10	132B197   851	5094022008	R4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.05	Electrical	Electrical	Apartment			07/18/2019 12:00:00 AM			PC Info Complete	09/06/2019 12:00:00 AM	ADDRESS	34.05565	-118.29966	NEW FIRE ALARM SYSTEM IN A 29 UNIT APPARTMENT COMPLEX CONSIST OF 1 FIRE ALARM PANEL, 1 ANNONCIATOR AND 118 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18120	14041-20000-06909	9212 N MONOGRAM AVE	91343	12	198B137   734	2676021023	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	PIN	34.23789763	-118.49237002	pv1 single family dwelling. total system size 3 kw ac using transformerless inverter nonstandard plan. using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18121	19041-10000-15092	1940 S BEDFORD ST	90034	10	126B169   480	4302024019	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/01/2022 12:00:00 AM	ADDRESS	34.0427	-118.38321	PLAN CHECK FOR POWER AND ENERGY FOR REMODEL OF 4 STORY(3 UNIT) APPARTMENT - SERVICE SIZE = 600A 120/240V, TOTAL AFFECTED AREA 2723 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18122	16041-20000-15490	21650 W OXNARD ST Ste 1980	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Existing commercial office remodel in commercial highrise building.  All new lights, all existing circuits.  Plan check for energy.  1084 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18123	13041-10000-32957	13280 N DRONFIELD AVE STE# 21	91342	7	225B153   556	2504018***	RD3-1-K	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.31289	-118.44322	PV1, Install  4 kw DC roof-mounted solar array for a 2 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 16 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18124	11041-20000-13627	254 N BEL-AIR ROAD	90077	5	141B153   148	4362022010	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Expired	09/23/2013 12:00:00 AM	ADDRESS	34.08259	-118.43734	Installing a new 80 Kw Generator for a single family House. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18125	11041-10000-12363	4880 E HUNTINGTON DR SOUTH	90032	14	142-5A233  73	5218007003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	34.08622	-118.17737	T.I.  Replacing restroom light fixtures.  PLan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18126	13041-10000-10718	13640-13648 W FOOTHILL BLVD	91342	7	222B157    94	2509014014	(T)(Q)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.3076	-118.43089	INSTALLING NEW ELEVATOR RECALL SYSTEM FOR THE PARKING STRUCTURE. SCOPE OF WORK LOCATED UNDER ADDRESS 13648.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18127	11041-10000-07601	12301 W WILSHIRE BLVD STE 615	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	05/27/2011 12:00:00 AM	PIN	34.04277409	-118.46969044	T.I.  REPLACING LIGHT FIXTURES IN AN EXISTING OFFICE SPACE.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18128	16041-20001-19928	6584 N FRANRIVERS AVE	91307	12	180B089   403	2034017034	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM			PC Approved	07/12/2016 12:00:00 AM	ADDRESS	34.19055	-118.65485	PV1.  Install 12.32 kW roof mounted PV system.  (44) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18129	15041-20000-24864	13921 W CHANDLER BLVD	91401	4	171B153   927	2247012032	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Expired	09/06/2017 12:00:00 AM	ADDRESS	34.16871	-118.4364	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.3 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18130	12041-10001-22214	117 E WINSTON ST	90013	14	129A213   451	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/07/2012 12:00:00 AM			PC Approved	12/13/2012 12:00:00 AM	ADDRESS	34.04713	-118.24718	REVISED EMERGENCY LIGHTING. FOUND GENERATOR. ISSUED CORRECTIONS TO SEE IF GENERATOR SUPPLIES E-LTG ON OTHER FLOORS. ELSE UNIT EQUIPMENT IS OKAY TO USETENANT IMPROVEMENT AND CHANGE OF USE OF A PORTION OF THE EXISTING RETAIL TO  A NEW BAR. EPC IS FOR POWER & ENERGY. ((((((( ADAPTIVE REUSE. RENOVATE EXISTING RETAIL & STORAGE SPACES ON BASEMENT AND GROUND FLOOR.  CONVERT SECOND THRU SEVENTH FLOORS TO JOINT LIVE AND WORK QUARTERS FROM EXISTING OFFICE USE. ELECTRICAL PERMIT# 10041-10000-02019, BLDG PERMIT# 09016-10000-11208, 12016-10000-11551))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18131	19041-20000-00331	333 S BENTEL AVE	90049	11	129B137   376	4406026012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.05017	-118.49253	Install 12.42 kW DC / 11.24 kW AC roof mounted grid tied PV system.  (36) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18132	17041-10000-20195	14040 W FOOTHILL BLVD	91342	7	225B153   250	2504019049	R3-1-CPIO	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	09/13/2020 12:00:00 AM	ADDRESS	34.31435	-118.43968	PC FOR PV SYSTEM CONNTECTED TO EXISTING MAIN PANEL. THIS IS COMMERCIAL PV. THIS SYSTEM USES 6 INVERTER, TOTAL RATED 65.6KW AC. THIS SYSTEM NET METERS METER # PMS222-11509. THIS IS SYSTEM 1/3 ON SAME ROOF. SYSTEM USES POWER OPTIMIZERS. Note: Permit fees are $0 due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18133	11041-10002-01682	11976 W CULVER BLVD 1-124	90230	11	108B161   154	4218007025	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Apartment			06/27/2012 12:00:00 AM			PC Info Complete	07/12/2012 12:00:00 AM	ADDRESS	33.99512	-118.4173	New 124-units affordable housing 4-storie over parking garage on grade. EPC is for power & Energy. (T24 fee is not included)(((( changes made to previosly approved set, two equipment changed per unit and aluminum used for copper feeders.))))))))))))))))) please contact  randall thompson at 310-466-2649	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18134	19041-30000-06923	4641 N CARITINA DR	91356	3	168B117   474	2178015005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.15457	-118.55667	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. System addition size is 2.12 kWdc/3 kWac and consists of (1) inverter, (8) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18135	19041-20000-09749	777 S FIGUEROA ST FLR 51, 52	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Remodel of restrooms on 51st and 52nd floors.  Plan check for energy. Building permit issued udner 18016-10000-38223.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18136	19041-20000-11282	184 S HUDSON AVE	90004	4	138B185   412	5515005008	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Closed	06/24/2021 12:00:00 AM	ADDRESS	34.07116	-118.33316	SERVICE UPGRADE TO 600A FOR SFD, INSTALLING A 600A MDP, AND (2) 225A SUB PANELS AND A 125A SUB PANEL. NO LOADS ON PANELS. FUTURE LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18137	18041-20000-48213	1333 S ORANGE GROVE AVE	90019	4	147B181  1088	5548023021	RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.05232	-118.36543	temporary power for construction site 600 amp service.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18138	17041-20000-36687	1225 N CHICKORY LANE	90049	11	141B137    99	4493025006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.08123	-118.48617	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.68 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18139	19041-10000-01065	5363 E ALHAMBRA AVE	90032	14	139-5A235 225	5220017027	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.07653	-118.169	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18140	16041-10000-22072	600 S HARVARD BLVD	90005	10	135B193   877	5503026007	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Issued	06/30/2016 12:00:00 AM	ADDRESS	34.06322	-118.30393	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTUARANT SPACE. SCOPE INCLUDES NEW EXTERIOR AND INTERIOR LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1471 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18141	18041-10001-21765	2827 S SANBORN AVE	90291	11	105A145   276	4227019011	R1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM			PC Approved	06/22/2018 12:00:00 AM	ADDRESS	33.9817	-118.46522	EXPEDITE PER APPLICANT REQUEST FOR PV JOB.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18142	19041-10001-23639	9631 N CALVIN AVE	91324	12	201B117   532	2761005009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Issued	11/13/2019 12:00:00 AM	ADDRESS	34.24526	-118.55562	0$ fee Due to AB 1414.change of an approved set of PV1 solar system. change includes 1-adding 2 solar module2-changing the module type to canadian solar 305w3-system size increased to 7.63kw4-main ocpd increased to 40A.original permit #: 19041-90000-23639 original scope: Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18143	14041-10000-09802	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	TENANT IMPROVEMENT AT LEVELS BASEMENT  THRU 2ND FL; ADDING COOLING TOWER ON ROOF OF PARKING STRUCTURE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18144	18041-10000-30995	2560 N GLENDALE BLVD	90039	13	150A209   265	5440001002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.10387	-118.25901	Plan check for T24 only, TI on (E) Cofee shop, total area under scope: 1,102 sq.ft(B# 18016-10000-26261)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18145	17041-20000-35093	20958 W STRATHERN ST	91304	3	189B109   375	2109010010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.21584	-118.5906	PV1.  Install 6.6 kW roof mounted grid tied PV system.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18146	18041-10000-42911	3616 S TROUSDALE PKWY 209	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.01983	-118.28534	PLAN CHECK FOR TITLE 24 ONLY FOR - EXISTING OFFICE, CONVERSION TO LAB T.I. AHF BUILDING #37, ROOM 209 SECOND FLOOR. TOTAL AFFECTED AREA = 1524SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18147	16041-10001-35521	5750 W WILSHIRE BLVD SUITE 105	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	Supplemental PC for changes to approved set. Relocating emergency panel E1M and adding new laundry panel with washer units. Adding and removing equipment. All changes clouded under delta 6 and delta 7.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18148	19041-20000-16158	12616 W VANOWEN ST	91605	2	180B161    41	2325002041	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	Apartment			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	07/23/2021 12:00:00 AM	ADDRESS	34.19375	-118.40783	Fire alarm system for new 3-story 6-unit apartment building.  FACP with annunciator and 32 signaling line and notification appliance devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18149	13041-20004-33082	1550 N EL CENTRO AVE	90028	13	148-5A189 331	5546026024	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.09961	-118.32359	07/14/2015 Changes to an approved set of plans. Plans have been modified to reflect all to-date field changes. All changes have been clouded and marked Delta 5, 6, 7, 8, 9, and 10.*****Previous Work Description*****CHANGE TO APPROVED SET OF PLANS. ADDITION OF A COUPLE NEW PANELS, UPGRADE TRANSFORMERS AND UPPER LEVELS, AND RELOCATION OF SOME LOADS. PLAN CHECK FOR POWER SYSTEM CHANGES. ALL CHANGES HAVE BEEN NOTED DELTA 3 AND DELTA 4.*****Original Work Description*****PC FOR POWER AND ENERGY. PER BUILDING, COMMON PARKING, SINGLE STRUCTURE. 4 ADDRESSES.PLAN CHECK HOURS CHARGED DUE TO GLITCH IN PCIS. THEY ARE EQUIVELENT TO 213000 SQRFT OF TITLE 24 PLAN CHECK. TOTAL SQRFT FOR T24 IS 1,117,551 SQRFT. TOTAL PRICE OF SUBMITTAL IS ABOUT $60K*****Building Permit Description*****New Below-Grade 5-level Parking Garage:  590,000 SF S-2 occupancy including B occupancy in accessory spaces (parking management office, building security office, etc.)New Six-Story Office Buildings:  10,150 SF A-2 occupancy (restaurant); 13,500 SF A-3 occupancy (fitness); 306,550 SF B occupancy (office); 2,100 SF M occupancy (retail)New Two-Story Office Building: 10,150 SF B occupancy (office)Future High-Rise Residential Tower: 1,800 SF A-2 occupancy (restaurant); 700 SF B occupancy (office); 6,000 SF M occupancy (retail); 245,600 SF R-2 occupancy (apartments)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18150	11041-10000-01767	8384 W 3RD ST	90048	5	138B173   836	5511031049	C2-1LD-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.07283	-118.37279	TI IN AN EXISTING HOTEL. INSTALL NEW AC's & HEAT PUMPS ON THE ROOF, NEW 225 KVA TRANSFORMER, NEW PANELS & CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18151	17041-10000-04621	20039 W RINALDI ST BLDG A6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.27566	-118.57078	PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 1000A 277/480 V 3 PHASE 4 WIRE SERVICE FOR A NEW CORE SHELL BUILDING(A6).  TOTAL AFFECTED AREA IS 5084 SQ FT.B# 16010-10000-06140	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18152	13041-10000-25593	6824 S BRYNHURST AVE	90043	8	102B185   600	4006023006	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	33.97619	-118.33366	TITLE 24 PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALL NEW FLUORESCENT FIXTURES. 6019 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18153	19041-20000-08248	6200 N DE SOTO AVE	91367	3	177B109   225	2149004020	(Q)C4-2D	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	11/14/2020 12:00:00 AM	ADDRESS	34.18284	-118.58981	PV2.  Install (2) PV systems: 102.57 kW DC / 93.72 kW AC and 45.99 kW DC / 42.02 kW AC roof mounted grid tied PV systems.  (281) modules with (1) 33.3 and (3) 20 kW rated string inverters for system 1; (126) modules with (2) 20 kW rated string inverters for system 2.  Interconnecting with 600A 208Y/120V 3ph-4w and 400A 208Y/120V 3ph-4w services.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18154	16041-20000-27169	6600 N TOPANGA CANYON BLVD Parking 1-3	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Issued	10/03/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check Title 24 only in existing parking Structure Retro-Fit existing lighting fixtures on the poles and ceiling of parking structure. PKG1: 592,026 sq ft. PKG 2: 116,817 sq ft. PKG 3: 104,583 sq ft. Outdoor area: 721,734 sq ft. Total all area: 1,419,276 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18155	16041-20001-05442	13630 W SHERMAN WAY	91405	2	183B157    73	2328008023	C1-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM			PC Approved	12/12/2016 12:00:00 AM	ADDRESS	34.20103	-118.42997	12/12/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Certificates. *****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. Change of use from Retail to Take-out restaurant (No Seating, (80.25' x 45.84')).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18156	15041-20000-21918	8527 W FOOTHILL BLVD	91040	7	207B189  1072	2555033013	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.2599	-118.31882	Plan check for power and energy for existing restaurant T.I. Service upgrade from 1phase 600A to 3 Phase 600A with new service equipment and panels. Total indoor and outdoor area: 1,770sqft and 1,575sqftCOMPLY WITHDEPARTMENT ORDER effective date 08/27/2015. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE. All permits shall be for the same timeperiod limitation. If additional assistance is needed, pleasecall Inspector DUANE JOHNSON at (213)252-3947.  CEIS Case Numberis 693507	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18157	14041-20000-07617	8200 N HASKELL AVE	91406	6	192B141   509	2673022049	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM			PC Info Complete	03/21/2014 12:00:00 AM	ADDRESS	34.21939	-118.47475	NEW LIGHTING. EXISTING WAREHOUSE AND OFFICES. PLAN CHECK FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED UNDER THIS APPLICATION. DUE TO CODE ENFORCEMENT, COMPLY WITH DEPARTMENT ORDER effective date 01/31/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. INVESTIGATION FEE HAS BEEN ADDED.CEIS Case Number is 530806	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18158	10041-20000-24144	11644 W VENTURA BLVD #B	91604	2	162B169   455	2369033008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			12/03/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Expired	01/30/2013 12:00:00 AM	ADDRESS	34.1406	-118.38625	T.I. to existing space for a new restuarant.  Install branch circuits and general lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18159	17041-30000-12920	10401 W WILSHIRE BLVD	90024	5	135B157   131	4360030023	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Apartment			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.06701	-118.4294	Plan check for the replacement of the FACP and the addition of (2) devices and (1) communication panel onto an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18160	19041-10000-41728	24218 W ST EDENS CIR	91307	12	183B089   378	2028034015	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.19735	-118.65231	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KWac PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 32 MODULES USING P320 OPTIMIZERS CONNECTED TO EXISTING 200A SERVICE. Fees $85.07 due to California Senate Bill 1222 and AB 1414MAIN BREAKER DERATE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18161	16041-10000-20666	5212 E STRATFORD ROAD	90042	14	156A225   203	5479013004	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.12222	-118.20174	PV SYSTEM USING 12 MODULES AND MICROINVERTERS. USING ENPHASE M215. 2.5KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18162	16041-20000-12275	1201 S HOPE ST	90015	14	126A207    34	5138026030	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	34.0408	-118.26471	Plan check for power and energy. Project scope is a new Mixed use 31 and 39 story High-rise commercial building  (two towers with adjoining underground parking lot). Total lighting area = 790,539 sq. ft.Reference 2 Building Applicantion #: 14010-10000-01784 & 14010-10000-01777	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18163	10041-10001-22352	1712 W PACIFIC COAST HWY	90717	15	033B193    51	7553018023	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM			Corrections Issued	04/11/2012 12:00:00 AM	ADDRESS	33.7893	-118.30821	TI for Mcdonald restaurant, replacing a panel, adding new light fixturs on existing circuits.  EPC is for T24.  <<<<<<<<<<<RECHECK OF T-24 WITH EMERGENCY DUE TO CHANGE BY CONTRACTOR.  PLAN CHECK ONLY, OTC>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18164	19041-10001-03654	13520 W PAXTON ST Unit A1	91331	7	210B157  1074	2535002015	M3-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.27356	-118.42606	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES REVISIONS TO LIGHTING LAYOUT, T24 HAS BEEN UPDATED ACCORDINGLY. ALL CHANGES CLOUDED UNDER DELTA 2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18165	17041-20000-39897	3000 S ROBERTSON BLVD 1 & 3 RR	90034	10	123B169   884	4311033015	C4-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.03242	-118.39001	PLANCHECK FOR T24 ENERY. TENANT IMPROVEMENT FOR BATHROOMS IN THE 1ST AND 3RD FLOOR. 1010 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18166	14041-10000-23013	328 S LA BREA AVE	90036	4	135B181   261	5507008021	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.06807	-118.34383	T24, TOTAL AREA 1360 SQ FT EXTERIOR LIGHTING  AND 4529 SQ FT INDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18167	18041-10000-35106	13207 N BRADLEY AVE	91342	7	225B145   352	2501005009	[Q]MR1-1, [Q]P-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.31041	-118.46654	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18168	15041-10001-00994	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***		Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Approved	03/07/2015 12:00:00 AM	ADDRESS	34.1504	-118.32742	MODIFYING TEMPORARY INSTALLATION; OVER CURRENT RELAYS ON THE SEC OF XFMR AND ADD LOAD INTERRUPTER SWITCH WITH FUSES ON THE PRI SIDE;HAVING THE MV XFMR MOUNTED ON A SKID AND THE INSTALLATION HAVING K-RAILS AROUND THE INSTALLATION INSTEAD OF WIRE FENCEPC FOR POWER.INSTALLATIN OF A TEMPORARY POWER SUPPLY FOR CONVEYOR SYSTEM(MEDIUM VOLTAGE).***approved by John per F.Y***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18169	15041-10001-33032	20790 W NORDHOFF ST Bldg 2-#5	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM			PC Info Complete	04/04/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	PC FOR POWER ONLY. FIRST TIME TENANT FOR NEW RESTUARANT. SCOPE INCLUDES THREE NEW PANELS AND BRANCH CIRCUITS.  NOTE: ENERGY PC UNDER PCIS#15041-10000-33032.  PERMIT ISSUED FOR EQUIPMENT UNDER 16041-20000-03759((((((T-24, CHANGE OF USE TO RESTAURANT IN AN (E) BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1315.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18170	17041-10000-00474	3217 N EASTERN AVE	90032	14	141A233    26	5213038036	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2014.01	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.08244	-118.17829	Plan check for power and energy for  core and shell, 1 story 3 units commercial building. 600A Service. Total lighing indoor and outdoor area: 14,590 sq ftBuilding Applicant number: 16010-10000-01215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18171	15041-30000-40310	1676 E 108TH ST	90059	15	088-5A213  73	6069002006	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Expired	02/20/2018 12:00:00 AM	ADDRESS	33.93769	-118.24341	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Single inverter system.  Address is not available for online permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18172	10041-20000-17633	13576 W DESMOND ST	91331	7	210B157   125	2523005023	M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	12/27/2010 12:00:00 AM	ADDRESS	34.27454	-118.42833	Plan check for 213.1 KW roof top Photovoltaic System commercial building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18173	14041-10000-10834	2303 N RIVERDALE AVE	90031	13	144B213   549	5445018031	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.09056	-118.23545	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 2.59KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18174	16041-20000-30704	445 S ARDMORE AVE 1-129	90020	10	135B193   591	5503009016	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			08/29/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.06592	-118.30178	Plan check for a PV2 roof-mounted PV system. System size is 40 kWac and consists of (4) inverters, (176) modules, and (1) load center.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18175	11041-10000-15875	11270 W EXPOSITION BLVD	90064	5	123B153   303	4256011900	[Q]PF-1XL	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.03472	-118.43639	INSTALLATION OF A MOTOR OPERATED VALVE,  POWER PANEL, AND CONTROL PANEL TO RELOCATE A SHELL PIPELINE DUE TO 405 WIDENING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18176	14041-10000-03320	10820 W VENTURA BLVD	91604	2	162B173   759	2378004003	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.1388	-118.36644	this is a one story bldg , rest. to restaurant.title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18177	17041-20001-41597	7565 W 80TH ST	90045	11	099B157   601	4114036021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	12/14/2017 12:00:00 AM	ADDRESS	33.96386	-118.43029	expeditepv1install roof mounted pv sytem with battery back up sized 2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18178	19041-20000-48772	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	02/22/2021 12:00:00 AM		Permit Finaled	11/16/2021 12:00:00 AM	ADDRESS	34.0754	-118.38272	Distribution and power for new chillers and associated equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18179	15041-10001-39275	2816 S ROBERTSON BLVD	90034	10	123B169   319	4301009004	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.03596	-118.38885	CHANGE TO 600A SERVICE UPGRADE. PC FOR NEW 600A SERVICE AND REPLACEMENT OF SUBPANELS. ALL LOADS TO BE RECONNECTED. NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18180	15041-20000-07611	16830 W VENTURA BLVD SUITE 315-320	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Issued	03/16/2015 12:00:00 AM	ADDRESS	34.15886	-118.50032	PC FOR OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18181	12041-20000-04233	281 S FIGUEROA ST # 100	90012	9	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.0554	-118.25452	INTIRIOR T.I. AT FIRST FLOOR OF (E)OFFICE BUILDING. Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18182	13041-10000-29449	11419 N MONTALCINO WAY	91326	12	213B109   412	2701068023	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Expired	12/21/2015 12:00:00 AM	ADDRESS	34.27907	-118.58671	PV1, installing roof-mouted solar array, interconnect with main panel, system size: 5.5 KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18183	12041-20001-18499	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	ADDRESS	34.06371	-118.3703	"][][changes made to an approved set of plans; revision due to inspector's request to reflect actual short ckt current @  . Accordingly, AIC rating of PNL ""BL1"" decreased from 42,000 to 35000A. no additional change per applicant. plan check only for power][]Install new emergency generator and panels and ATS to serve the 23rd floor of the building.  Plan check for power.  The location of equipment is on levels P1, P2, the 23rd floor, and on the roof."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18184	18041-20001-44029	1474 E 92ND ST	90002	15	094-5A211  45	6048001017	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	PIN	33.95297022	-118.24797128	expeditepv1install roof mounted pv system sized 5KW aC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18185	19041-20000-04099	7226 N CANOGA AVE	91303	3	186B105   631	2111029001	(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			02/04/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.2021	-118.59752	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 746 sq. ft.Note: Building permit had been issued under 15016-20000-07117 and renewed under 19016-20000-02722 at 75% completion. Electrical plan set has been reviewed under the 2013 Title 24 Compliance Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18186	19041-10000-32976	1026 S BROADWAY	90015	14	126A209    92	5139014017	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.04029	-118.25788	FULL PLAN CHECK adding one 75kva transformer and 2 panels. TOTAL AFFECTED AREA IS 5309 SQ.FTB#19016-10000-26324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18187	17041-10000-23597	3361 N ANDRITA ST LOT 1	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 1 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05783	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18188	16041-10000-21309	865 S FIGUEROA ST 18TH FLOOR	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN CONFERENCE ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18189	16041-10000-26500	8619 N AURA AVE	91324	12	195B117   379	2783021017	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Expired	09/05/2018 12:00:00 AM	ADDRESS	34.22693	-118.55486	PC for PV1. Installing 26 Panels with 26 microinverters rated at 215 W.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18190	19041-20000-20187	2347 N MORENO DR	90039	4	150A205   390	5432014012	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	34.10347	-118.26871	PV1.  Install 10.56 kW DC / 9.72 kW CEC AC roof mounted grid tied PV system.  (32) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18191	13041-20000-35011	2421 N MORENO DR	90039	4	150A205   261	5432015011	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.10472	-118.26879	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 13.2KWAC. 47 MODULES AND 3 INVERTERS $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18192	11041-20000-06625	21200 W OXNARD ST	91367	3	177B105    75	2149002008	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02, 1371.02	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.17905	-118.59389	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR PHASE II OFFICE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18193	18041-10000-38519	29050 S WESTERN AVE	90732	15	021B193    39	7445004242	(Q)C2-1VLD	Harbor	San Pedro		YES	2963.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.7545	-118.30904	PC FOR CHANGE OF USE FROM (E) ICE CREAM SHOP & MEDICAL OFFICE CHANGE TO DRY CLEANER FOR A RETAIL TI T-24 ENERGY ONLY. TOTAL AFFECTED AREA 2430 SQ.FTSCOPE INCLUDES NEW PANELS, CIRCUITS AND LIGHTS AND EQUIPEMNT.B# 18016-10000-30190	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18194	15041-10001-26202	9168-9174 N DE SOTO AVE	91311	12	198B109   134	2748036017	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM			PC Approved	12/29/2015 12:00:00 AM	ADDRESS	34.23762	-118.58834	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 REVISIONS. REMOVE SCOPE - OFFICE AREA FURNITURE. MARKED AS FUTURE LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18195	12041-10000-26604	18515 W BURBANK BLVD	91356	3	174B125   373	2160003039	C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.1725	-118.53644	TI IN AN EXISTING GAS STATION. INSTALL NEW PANEL & LOAD IN HAZARDOUS AREA. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18196	19041-10000-53042	1447 W AVON TER	90026	13	144B213   687	5415007022	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Expired	11/16/2023 12:00:00 AM	ADDRESS	34.0894	-118.24564	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.51KWdc / 5.09KWac.(19)MODULES-RECE290TP2(19)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SE5000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18197	11041-10000-07923	5300 N LANKERSHIM BLVD	91601	4	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	07/19/2011 12:00:00 AM	ADDRESS	34.16715	-118.37571	NEW FIRE ALARM SYSTEM IN EXISTING 2-STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18198	13041-10000-07786	770 W WILSHIRE BLVD Floor 8	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	04/01/2013 12:00:00 AM	ADDRESS	34.04914	-118.25811	Title 24 plan check for 8th floor retrofit of a 9-story office highrise.  10,000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18199	15041-20000-32931	3730 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Apartment			10/05/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.0201	-118.29002	TI to existing aparment building. Plan check for energy only. Adding outdoor lighting (2 new lights). Total sqft. 836.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18200	15041-10000-41922	1400 S GRAND AVE ste 101	90015	14	124-5A207  58	5134020023	C2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.03697	-118.26528	TI TO MEDICAL OFFICE. NEW LIGHITNG AND POWER. PC FOR T24 POWER AND ENERGY. REUSE MOSTLY EXISTING CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18201	18041-20001-45638	17044 W JERSEY ST	91344	12	207B133   105	2696021018	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Issued	01/09/2019 12:00:00 AM	ADDRESS	34.26751	-118.50382	01/09/2019 Changes to an approved set of plans. System size is now 8.7 kWdc/7.6 kWac. Inverter rating has remained the same. Module count has increased to (30).*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 8.12 kWdc/7.6 kWac and consists of (1) inverter and (28) modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18202	12041-10001-01814	651 S MISSION ROAD	90023	14	124-5A219  39	5171015902	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM			Verifications in Progress	12/11/2012 12:00:00 AM	ADDRESS	34.03612	-118.22649	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18203	18041-10000-15144	4610 S MAIN ST	90037	9	112-5A205 280	5109002051	C2-1VL	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Issued	10/05/2018 12:00:00 AM	ADDRESS	34.00159	-118.27377	"""0$ PERMIT FEES DUE TO SENATE BILL 1222, AB 1414""PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 38.79 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18204	13041-10000-34208	1163 E 11TH ST	90021	14	123A213   141	5132007042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.03129	-118.24525	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.For autoshop (NON-HAZARDOUS PER APPLICANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18205	16041-10000-18611	8884-8888 W VENICE BLVD	90034	10	123B169  1385	4312015005	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.02979	-118.3869	"Plan check for Title 24 Energy only. Checking exetrior facade lighting with hardscape area of 23700 sqft. Not checking the sign lighting. 3- canony, 10' x 52', 10' x 27'6"" 10' x 19'4"" and facade work at exterior of building"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18206	14041-10000-06631	1015 S CROCKER ST # R4	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 28090 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18207	15041-10000-29690	12506 W WAGNER ST	90066	9	108B157  1741	4221005050	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	33.98792	-118.42177	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18208	17041-20000-41517	14222 W VICTORY BLVD	91401	6	180B153  1098	2240013007	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			11/16/2017 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	04/14/2022 12:00:00 AM	ADDRESS	34.18644	-118.44306	PLAN CHECK FOR POWER AND ENERGY.  (N) 3-STORY 18-UNIT TYPE V-A AFFORDABLE HOUSING APARTMENT OVER TYPE 1-A BASEMENT GARAGE.BUILDING PERMIT # 17010-20000-01987	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18209	11041-10000-23468	2012 W 69TH ST	90047	8	102B189   767	6016029030	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	33.97688	-118.31389	New 8.6KW, rooftop, Photovoltaic system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18210	18041-20000-10578	624 S ORANGE DR	90036	4	135B181   681	5507021026	R1R3-RG	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.06424	-118.34172	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (44) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18211	15041-10000-25100	10176 N RESEDA BLVD	91324	12	204B125   232	2731018018	P-1VL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM			PC Info Complete	08/04/2015 12:00:00 AM	ADDRESS	34.25589	-118.53588	TI TO AN EXISTING COMMERCIAL BUILDING, RESTAURANT. NEW LIGHTING AND NEW CONTROLS USING EXISTING PANELS. PC FOR ENERGY AND EMERGENCY LIGHTING ONLY. TOTAL SQ. FT. 1715.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18212	16041-10000-37856	1445 W 62ND ST	90047	8	105B193   746	6002025028	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	33.98336	-118.30179	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(18)MODULES-SOLARCITY#SC265(1)INVERTER-PVI 5000 OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18213	12041-10000-09985	10341 W MAGNOLIA BLVD	91601	4	171B177   602	2417018030	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	34.16506	-118.35633	CONVERT ENCLOSED COMMOM AREA  IN AN APARTMENT BUILDING AS A LEASING OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18214	19041-10001-31320	5220 W WASHINGTON BLVD	90016	10	126B177   869	5063001035	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM			PC Approved	10/02/2019 12:00:00 AM	ADDRESS	34.04128	-118.35472	Expedite per applicant request.(((PC FOR PV-2 SOLAR SYSTEM. SYSTEM SIZE 30KW. 98 MODULES (CANADIAN SOLAR CS6K-305MS),   4 INV (7700TL - US), 2-100A DISCONNECT SWITCH.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18215	15041-20000-38666	2416 E 8TH ST	90021	14	123A217   318	5166007010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	ADDRESS	34.02943	-118.22921	TI to existing commercial building (warehouse with offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 9,687 conditioned and 1,196 unconditioned.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18216	17041-10000-17861	2215 S WESTWOOD BLVD	90064	5	126B157   457	4322002025	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.04321	-118.43144	PC for energy only, Indoor Title 24 to Restaurant TI. Adding a new subpanel, lighting and power. Area: 1408 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18217	19041-20000-44738	743 N SEWARD ST	90038	4	141B185   348	5533037003	CM-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.08469	-118.33326	INSTALL (60) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18218	19041-10000-23640	6862 N HAYVENHURST AVE	91406	6	183B137   380	2224019016	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.19561	-118.49221	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18219	13041-10000-01167	11027 W SANTA MONICA BLVD	90025	5	129B153   689	4324031093	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.04852	-118.44221	Demo 5,400 sf of retail auto sales portion of  (E) auto sales/garage building, add 2-story showroom and office of 11,163 sf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18220	13041-10000-23012	12524 W PRESNELL ST	90066	11	105B157   451	4221026022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	33.98473	-118.42052	PV1.  Install 7.35 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18221	14041-20000-28732	17201 W INDEX ST	91344	12	210B133    78	2697014007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.27576	-118.50787	PV1.  Install 7.54 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18222	15041-20000-04721	17513 W BULLOCK ST	91316	5	177B129   449	2254033001	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Expired	03/14/2017 12:00:00 AM	ADDRESS	34.17978	-118.51463	PV1CENTRAL STRING INVERTER STANDARD PLAN.  SYSTEM SIZE 5.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18223	12041-20000-30459	3075 W WILSHIRE BLVD	90010	10	135B197  1198	5077009005	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20, 2122.04	Electrical	Electrical	Apartment			12/18/2012 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.06197	-118.28885	New fire alarm system for 9 story highrise residential building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18224	13041-20000-17163	8500 W BEVERLY BLVD SUITE 707	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM			PC Approved	06/27/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	T24 FOR RETAIL SPACE LOCATED ON THE BEVERLY CENTER SUITE 707. TOTAL SQRFT 2848	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18225	17041-10000-07243	10250 W SANTA MONICA BLVD 1960	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR FIRST TIME TI ""LULULEMON ATHLETICA""  IN WESTFIELD CENTURY CITY. SUITE 1960"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18226	14041-10000-20246	11221 W PICO BLVD	90064	5	123B153   146	4322023038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.03594	-118.43757	PLAN CHECK FOR POWER only. all existing indoor lighting to remain. added refrigerated cases and receptacles at sales area and receiving/stockroom. added new outdoor lights. New service and TI to (e) smart and finals.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18227	18041-10000-30138	6615 W 86TH PL	90045	11	096B165   598	4122014023	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Apartment			08/09/2018 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	33.9594	-118.40512	PC FOR T24 ENERGY ONLY FOR APARTMENT COMMON STAIRWELL AND OUTDOOR LIGHTS. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 1950 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18228	19041-20000-51705	595 S MAPLETON DR	90024	5	138B157    76	4359013016	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	01/20/2021 12:00:00 AM	ADDRESS	34.07362	-118.42902	PV1. INSTALL 22.57 KW DC AND 19.17 KW AC ROOFMOUNTED PV SYSTEM WITH (61) AC MODULES(370WATTS) CONNECTED TO 600 AMP (E) SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18229	14041-20000-19993	13631 N ELDRIDGE AVE	91342	7	228B157   789	2510007001	RA-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.3193	-118.42669	Roof mounted PV system with Optimizer.  Total system is 7.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18230	17041-20000-05617	10525 N SHOSHONE AVE	91344	12	207B129   818	2733011002	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.26198	-118.51781	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP.5.2kW ungrounded system. (23) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18231	17041-20000-44059	7215 N CLYBOURN AVE	91352	2	183B177    32	2410021009	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	04/12/2021 12:00:00 AM	ADDRESS	34.20171	-118.36247	TI to an existing commercial building.  Adding new lighting new controls to new panels.  Plan check for energy only.  Total connected load < 400 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18232	15041-20000-42655	15840 W SAN FERNANDO MISSION BLVD	91344	12	210B141   584	2667013006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.27173	-118.47753	Plan check for PV roof mounted system. System size: 3.8kWac with 16 modules and 1 inverter(3.8kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18233	10041-10000-02188	4211 S REDWOOD AVE	90292	11	108B153  1182	4230006024	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Public Safety Only			02/08/2010 12:00:00 AM	02/08/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	33.98921	-118.439	Plan check for new installation of fire alarm system in 47 units condo building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18234	16041-20000-45393	10046 N SAMOA AVE	91042	7	202-5A199  24	2568006050	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			12/28/2016 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.25157	-118.28721	permit fee $0.00 by state senate bill no.1222 Plan check for a PV2 roof-mounted PV system. System size is 170 kWac and consists of (2) inverters, (576) modules, (12) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18235	17041-20000-39742	6120 N YOLANDA AVE	91335	3	177B121   497	2127016018	MR1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.18132	-118.54025	new fire alarm system 65 devices and facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18236	19041-10000-51296	2450 S CORINTH AVE	90064	11	123B153   405	4260040026	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Apartment			12/12/2019 12:00:00 AM			Reviewed by Supervisor	01/22/2020 12:00:00 AM	ADDRESS	34.0336	-118.43856	NEW APARTMENT BULDING. INSTALLING A 600AMP SERVICE, PANELS & CIRCUITS.(((BULDING PERMIT: 19010-10000-01652 ==> 10 UNIT MULTI FAMILY BUILDING WITH TOC TIER 3 3 STORY RESIDENTIAL OVER 1 LEVEL OF UNDERGROUND PARKING))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18237	16041-10000-15118	732 S SPRING ST	90014	14	127-5A211 161	5144015029	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.04346	-118.25305	Temporary Power for a new apartment building, 24 stories high rise, 300 units. Total Sq ft = 308000. Temporary equipment includes a 1600 amp service with connected load over 400 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18238	18041-20000-45062	1617 N CASALE ROAD	90272	11	132B133    39	4425001012	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.06141	-118.50295	PV1.   Installation of a 20.5 kW roof mounted grid tied PV system.  (52) modules with microinverters.  Removal of (E) PV system.  Derating of main service disconnect.$29.44 permit fee due to State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18239	13041-20000-11047	19767 W BAHAMA ST	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.23352	-118.56408	TI TO EXISTING WAREHOSE SPACE. CHANGE OUT FIXTURES FOR MORE ENERGY EFFICIENT FIXTURES. CONTROLS CHANGE BUT LOCATION OF OUTLETS EXISTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18240	19041-20000-47745	8922 N FARRALONE AVE	91304	12	195B101    36	2010021001	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.23327	-118.60825	PV1. PLAN CHECK FOR NEW PV SYSTEM, SYSTEM SIZE IS 17.82 KW DC/15.2 KW AC. SCOPE OF WORK CONSISTS OF (54) PV MODULES WITH OPTIMIZERS AND (2) 7.6 KW INVERTERS AND A SUB PANEL.$0 PERMIT FEE IS DUE TO SENATE BILL SB 1222 AND ASSEMBLY BILL AB 1414.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18241	17041-20000-33473	12800 W RANGOON ST	91331	6	198B161   319	2629027017	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Closed	09/28/2017 12:00:00 AM	ADDRESS	34.23789	-118.41231	Plan check for power only. Install a temporary 300kVA 277/480V generator to feed existing loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18242	15041-20000-00950	10061 N COZYCROFT AVE	91311	12	204B109   362	2741029016	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.25341	-118.58209	PC FOR PV SYSTEM. TOTAL SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 23 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18243	17041-10000-45865	851 N SANBORN AVE	90029	13	144A201   352	5427004008	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Apartment			12/21/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.08745	-118.28415	UPGRADE SERVICE AND REPLACE PANELBOARDS; WIRING IN THE APARTMENTS REMAINED THE SAMENOTE : PANELBOARDS FOR THE CIRCUITS INSIDE THE APARTMENTS ARE LOCATED OUTSIDE THE APARTMENTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18244	13041-10001-32625	10325 N LUBAO AVE	91311	12	204B113   128	2708017035	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.2582	-118.56881	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLARY ARRAY. TRANSFORMERLESS UNGROUNDED. SYSTEMSIZE: 6.50KW DC. 1 STORY.(26) RENESOLA SOLAR MODULES JC250M(26) POWER OPTOMIZERS(1) SOLAREDGE INVERTER SE6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18245	14041-20000-35414	9901 W WASHINGTON BLVD 102	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.02174	-118.39786	Plan check for power and energy. CHANGE OF USE FROM RETAIL TO RESTAURANT OF AN EXISTING 2,218 S.F. SPACE AND ADD NEW EQUIPMENT MEZZANINE FOR STORAGE PER ZA 2011-2464 (ZV). Total area w/Add. is 2,516sqft. New lighting (incl. emergency). Installing >400A of new load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18246	08041-10001-21597	5557 E VALLEY BLVD	90032	14	139-5A237  59	5220032003	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	03/05/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.07723	-118.16241	Plan check for Delta 1 revision.  Relocate/increase xfmr size, relocate panel, and add sump pump.  Stand-By power remove for future.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18247	17041-10000-21947	523 W 6TH ST 10TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC FOR LIGHTING UPGRADES IN CORRIDOR 10TH FLOOR. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18248	19041-10000-46810	7425 N SEPULVEDA BLVD	91405	6	186B145   441	2222019095	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Issued	11/14/2019 12:00:00 AM	ADDRESS	34.20548	-118.46639	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18249	14041-10000-34938	8071 N SEPULVEDA BLVD	91406	6	189B145   128	2654037026	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	PIN	34.21756987	-118.4669169	Remove HID light fixtures and replace with new fluorescent fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18250	15041-10000-23295	12800 W CULVER BLVD MER 6A-4K	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	33.98489	-118.42552	FULL PC, TI TO AN (E) OFFICE BUILDING, DIRECT TV. SCOPE OF WORK INCLUDES NEW PANELS AND LIGHTING, TOTAL CONNECTED LOAD > 400AMPS. TOTAL SQ. FT. 944. PC FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18251	14041-10001-21186	2718 S FIGUEROA ST	90007	9	121-5A203 129	5123018032	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM			PC Approved	01/14/2015 12:00:00 AM	ADDRESS	34.02678	-118.27665	Changes to approved set by replacing kitchens lights with new lights. all changes are under delta-1 only.(((permit to be pulled at EPC counter only. PLAN CHECK FOR ENERGY ONLY (2008 standards). Taco Bell TI. BLDG#14016-10-08847: REMODEL TO EXISTING RESTAURANT,  FACADE REMODEL,  DINING ROOM REMODEL AND RELOCATION OF SOME KITCHEN EQUIPMENT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18252	15041-10002-10686	13155 W HARTSOOK ST	91423	4	171B157   686	2358001002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.16408	-118.41994	Per senate bill 1222 the fee was capped to $0. Change to an approved set by replacing original inverter with (2) PVI3.8 inverter and adding new subpanel.(((PV1 ROOF MOUNTED, ONE FLOOR RESIDENTUAL. SIZE OF INVERTER7.5. AND 24 MODULES.  TOTAL 7.85KW -DC.  SUBMITTAL PER APPLICANT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18253	17041-20000-39836	10330 W ROCHESTER AVE	90024	5	135B157   403	4327015002	R1V3-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.06412	-118.42492	pv1install roof mounted pv system sized 13.4kw interconnected with msp.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18254	15041-10000-08758	1536 W 228TH ST STE # B	90501	15	045B193   410	7347017077	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	33.8189	-118.30499	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES, TOTAL AREA 9750 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18255	14041-10000-27226	8900 W DEVLIN PL	90069	4	144B169    70	5560036001	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.09456	-118.38498	INSTALL 12.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(48) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER(S): SOLAREDGE SE3800A-US-ZB-U & SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18256	15041-30001-37299	17400 W BURBANK BLVD	91316	5	174B129   863	2254036026	R3-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.17211	-118.51191	Expedite fees only.Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 30.8 kWac.  System consists of 4 7.7 kWac inverters with 27 modules each.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18257	18041-30000-22198	337 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	33.77317	-118.27877	Energy plan check for warehouse T.I . Scope includes new lighting and equipment with a total area cover 8500-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18258	14041-10000-03570	1735 N VINE ST	90028	13	148-5A187  55	5546004403	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			02/07/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Expired	03/10/2016 12:00:00 AM	ADDRESS	34.10272	-118.32695	PLANCHECK FOR TITLE 24 ENERGY. BATHROOMS AND LOBBY AREA . GROUND FLOOR. 3755 SQFT , EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18259	10041-10000-08841	8052 W 3RD ST 2ND FLOOR	90048	5	138B177   752	5511028012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	05/12/2010 12:00:00 AM		Permit Finaled	05/18/2010 12:00:00 AM	ADDRESS	34.07183	-118.36564	IT-24 lighting plan check for both 2nd floor office spaces as shown on page E2.2.  The second floor offices are at address 8052 W 3rd Street.  A permit for one branch circuit for the smaller open office area is issued with this plan check for the new lighting to be installed.  See existing permit for the circuits for the larger open office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18260	18041-10000-33106	9641 N TUJUNGA CANYON BLVD	91042	7	198B201    57	2572018015	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.24269	-118.27397	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18261	11041-20000-11923	12440 N SAN FERNANDO ROAD	91342	7	219B149   481	2507007025	P-1, [Q]M1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/10/2011 12:00:00 AM	ADDRESS	34.29651	-118.45454	Install indoor and outdoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18262	17041-20001-34474	14329 W JOY DR	91331	6	198B153  1034	2644027246	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24147	-118.44553	Revision to approved set.  Change to higher power module type and inverter rating increased to 3.8 kW AC. (((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18263	16041-20000-42590	6600 N TOPANGA CANYON BLVD Ste 2070B	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is an existing retail space within a commercial building. Project scope is a tenant improvement. Total lighting area = 2,700 sq. ft.Note: Building application has been generated under 16016-40000-28816	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18264	16041-20000-01987	368 N NORTON AVE	90004	4	138B189    83	5522027002	R1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	03/12/2016 12:00:00 AM	ADDRESS	34.07813	-118.3169	Plan check for PV roof mounted system. System size: 6.0kW with 24 modules and 1 inverter(6.0kW). Center feed with derated main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18265	14041-10000-28577	1011 S LONG BEACH AVE	90021	14	121-5A213  19	5130024027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.02837	-118.24124	PV 2 System roof mounted  103.95 KW (378) modules: Solar World Sunmodule plus SW 275 AOMO, (8) combiner box, and (4) inverters Model:  Trio-20 TL-OUTD and Trio-27.6 TL-OUTD . Per Senete Bill 1222 zero fee for permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18266	16041-10000-16051	1439 N TAMARIND AVE 1-21	90028	13	147A191   121	5545014011	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.09675	-118.3192	Full PC for a new 4 story (21) unit apartment building. 2 typical units (work in progress, additional typical units may be provided for revision period). New serive rated at 1200 A. Total sqft = 1623	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18267	10041-10000-25743	325 W ADAMS BLVD	90007	9	123A205   197	5126018035	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Closed	11/16/2012 12:00:00 AM	ADDRESS	34.02712	-118.27319	NEW 800 AMP TEMPORARY POWER FOR A NEW 6 STORY MIXED USE BUILDING.   (EPC # 10041-10000-25737 & 10041-10000-25736)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18268	16041-10000-03511	1245 W WILSHIRE BLVD # 300	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	PC FOR POWER AND ENERGY, FIRST TIME TENANT. MEDICAL OFFICE. TOTAL AREA 6866 SQ FT.TALORED METHOD. CORE &SHELL APPLICATION # 10041-20003-24663	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18269	16041-20000-34786	15455 W MILLDALE DR	90077	5	156B145    24	4378010012	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.12683	-118.46885	PV1.  Install 5 kW roof mounted grid-tied PV system over accessory structure, interconnect into replacement panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18270	18041-10000-06312	11975 W SANTA MONICA BLVD	90025	11	126B145   527	4263029127	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.04127	-118.46229	PC for T24 only for retrofit lighting. Replacing existing lights with new LED light retrofits. Total area 3200sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18271	19041-10000-20966	13260 W SHERMAN WAY	91605	2	183B157    93	2327004037	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.20103	-118.42199	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18272	19041-20000-51288	6640 N VAN NUYS BLVD	91405	6	180B149   272	2237001018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	34.19188	-118.44844	TENANT IMPROVEMENT ADD NEW LIGHTING FIXTURES PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18273	17041-10000-36967	333 S GRAND AVE 16TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	plan check for office TI in a high rise building, 16th floor, for title 24 energy only. scope of work includes new lights, and recepticalstotal effected area is 4737 sqr ftINTERIOR OFFICE TI INCLUDING A NEW DEMISING WALL,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18274	16041-10002-16952	8337 N LAUREL CANYON BLVD	91352	2	192B165   248	2633006019	P-1VL	North Valley	Sun Valley			1210.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			PC Approved	08/19/2016 12:00:00 AM	ADDRESS	34.22287	-118.3967	THIS IS FULL PC FOR MEDICAL OFFICE IN ACCORDANCE TO ART 517. ENERGY ALREADY APPROVED AND PERMIT ISSUED UNDER MASTER. THIS APPLICATION IS PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18275	16041-20000-04625	6256 N TOPANGA CANYON BLVD C-1310	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	Plan check for power and energy. Project site is an existing commercial space. Project scope is a first time tenant. Total lighting area = 1,891 sq. ft.Note: Building application has been generated under 16016-20000-01771	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18276	17041-20002-32559	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.06371	-118.2982	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES ARE NOTED UNDER DELTA #2 - CHANGES INCLUDE EMERGENCY LIGHTING FOR ALL (F) TENANT/RETAIL SPACES FIRST, SECOND, AND THIRD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18277	19041-10001-19624	17612 W TRAMONTO DR	90272	11	126B117   376	4416021012	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.04174	-118.55931	CHANGES TO AN APPROVED SET. REDUCING NUMBER OF MODULES FROM 48 TO 44. ORIGINAL (([E-PLAN], PV1. NEW ROOFTOP SOLAR SYSTEM CONSISTING OF 48 MODULES (SUNPARK 300), 2 INVERTERS (SE7600H-US AND SE3800H-US) AND 48 OPTIMIZERS (SE P320). SCOPE INCLUDES NEW 100A LOAD CENTER))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18278	18041-20000-40036	14631 W DICKENS ST	91403	4	166-5A149  93	2276002***	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Apartment			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.15059	-118.45307	Plan check for replace new fire alarm panel  and add 1 new smoke detector above fire alarm, 1 new pull station and tie existing fire alarm devices to the new Fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18279	16041-20000-04949	12401 N NEDRA DR	91344	12	219B137   105	2609022017	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	04/30/2016 12:00:00 AM	ADDRESS	34.29543	-118.49855	Plan check for PV roof monted system. System size: 7.6kW with 37 modules and 1 inverter(7.4kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18280	17041-20001-15064	2947-2947 1/2 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Apartment			05/05/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.03802	-118.20335	Plan check for a PV2 roof-mounted PV system. System size is 1.72 kWac and consists of (8) modules and (8) micro-inverters. Project site is (2) duplexes on the same property both served by a single 400-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18281	12041-10000-23748	827 W BARHUGH PL	90731	15	024B197   170	7442019006	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	33.76162	-118.29671	4.6 kw roof mounted PV for a single family. (transformerless inv.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18282	13041-10000-33880	1188 S SAN PEDRO ST SUITE J	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	PIN	34.03375994	-118.25280059	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 420 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18283	15041-10000-44015	7417 N PONCE AVE	91307	12	186B097   638	2022007010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.20514	-118.62158	PV1 roof mounted installation to a single family home. (1) inverter : 10 kw, (46) solar modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18284	14041-20001-18659	10531 N OKLAHOMA AVE	91311	12	207B109   550	2706012008	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			PC Approved	07/19/2014 12:00:00 AM	ADDRESS	34.26194	-118.58658	Expedite per customer request(((PV1 12.24KW roof-mounted system with (48) Trina solar TSM-255P modules and Solaredge p300 Powerbox Optimizers, and (2) Solaredge SE5000 inverters connecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18285	14041-10000-02418	725 S FIGUEROA ST 40TH FL	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.04886	-118.26071	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT  AT 40TH  FLOOR OF (E) HIGH-RISE OFFICE BUILDING . 9315 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18286	17041-10000-33895	12036 W VENTURA BLVD F305	91604	2	162B165   133	2369015016	(Q)C2-1VL-RIO, (Q)P-1VL-RIO, C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.14353	-118.39377	PC FOR RETAIL TI (CHANGE OF USE FROM RESTAURANT (A-2) TO MERCHANTILE (M).)CHECKING FOR TITLE 24 ENERGY AND POWER. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS TOTAL AFFECTED AREA 5602 SQ.FT. B#17016-10000-27540	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18287	19041-30000-00204	9200 N GLENOAKS BLVD	91352	6	198B173   111	2408001003	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	12/23/2021 12:00:00 AM		Permit Finaled	03/24/2023 12:00:00 AM	ADDRESS	34.2363	-118.37296	Addition to an existing two-story office building and complete tenant improvement. Building distribution supplied from (E) 1000A 480Y/277V 3ph-4w service.  Total lighting area = 29,569 sq. ft.Note: Building application has been generated under 19014-30000-00015	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18288	10041-10000-19271	200 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	12/13/2010 12:00:00 AM	PIN	33.94153561	-118.3984113	Replace elevator(s) and other electrical upgrade.   Plan checked at applicants request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18289	19041-20000-41041	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18290	13041-20000-13488	9039 N TOPANGA CANYON BLVD	91304	12	195B101    17	2010004047	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Issued	05/23/2013 12:00:00 AM	ADDRESS	34.23474	-118.60488	Rewire and change lighting to an existing retail space.  (5' addition added to space.)  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18291	16041-10000-23812	1854 S SAWTELLE BLVD	90025	11	126B153   436	4261020019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.04272	-118.44498	NEW FIRE ALARM SYSTE FOR 5-STORY WITH 2-LEVEL PARKING GARAGE, WITH 104 AND ONE FA PANEL AND ONE ANNONCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18292	18041-20000-03058	13286 N RALSTON AVE	91342	7	225B141   161	2501002042	[Q]MR1-1, [Q]P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.31344	-118.47347	PLAN CHECK FOR POWER ONLY FOR NEW SERVICE UPGRADE FROM 400A TO 2000A DISTRIBUTION SYSTEM. PLAN CHECK ONLY INCLUDES UPGRADE WITH INSTALLATION OF 4 NEW PANEL WITH NO NEW LOAD AND CONNECTING EXISTING EQUIPMENT TO NEW SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18293	10041-20000-23330	600 S SPRING ST #1	90014	9	129A211   252	5144001020	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.04568	-118.25098	Change of used to Coffee Bar Restuarant of a high rise building.  Install general/emergy lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18294	18041-10000-18610	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			05/18/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	02/28/2021 12:00:00 AM	ADDRESS	34.06259	-118.35341	PC FOR TEMP POWER FOR NEW PROPOSED 225 UNITS HIGH RISE RESIDNTIAL BUILDING. SCOPE INCLUDES NEW SERVICE 1600A 480/277V (IN METHANE ZONE) WITH HOIST CRANES AND PANELS.B#17010-10000-04785	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18295	11041-20000-14098	6840 N SEPULVEDA BLVD STE 101	91405	6	183B145   661	2220020018	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	05/15/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.19522	-118.46594	PLAN CHECK POWER AND ENERGY. T. I. FOR OUT-PATIENT DIALYSIS CLINIC 1ST FLOOR. NOT PLAN-REVIEWED FOR OSHPD III	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18296	18041-10000-35140	1822 S SELBY AVE	90025	5	129B153   460	4321004009	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			09/13/2018 12:00:00 AM			Reviewed by Supervisor	10/18/2018 12:00:00 AM	ADDRESS	34.05015	-118.43292	New four story 10-unit, apartment building.Building Permit: 18010-10000-01529	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18297	15041-10000-07824	2617 N CORRALITAS DR	90039	13	148-5A211 262	5440031021	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Refund in Progress	07/08/2016 12:00:00 AM	ADDRESS	34.09931	-118.25271	PV1 3.8KW roof-mounted system including (1) load center , (1) Solaredge SE3800 inverter , (16) Kyocera KU255 PVmodules and Solaredge P300 power optimizers. Note: online service does not recognize the address.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18298	18041-10000-26941	16611 W ROSCOE PL	91343	12	192B137   283	2689010011	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.22138	-118.49442	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18299	18041-20000-47179	10749 N FARRALONE AVE	91311	12	207B101    54	2723006031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/24/2018 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.26547	-118.61065	Plan check for PV roof mounted system, system size: 15.12kW DC, 13.44kW with 42 AC Modules, 100A sub panel.Note: Permit fee due to CA Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18300	10041-10000-20717	1053 S CRENSHAW BLVD 1ST FL	90019	10	129B189    95	5082027025	C2-1-O	Central	Wilshire	Olympic Park		2127.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	34.05336	-118.32396	ON THE FIRST FLOOR OF 2-STORIES BUILDING, CHANGE OF USE FROM MEDICAL OFFICE TO MASSAGE THERAPY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18301	16041-20000-35269	8818 N OAK PARK AVE	91325	12	195B133   293	2690011015	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.23086	-118.50535	Plan check for the addition of PV system onto an existing PV1 roof-mounted PV system. System addition size is 3 kWac and consists of (1) inverter, (11) modules, and (1) load center. Total system size is 9 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18302	15041-20000-26442	8341 N LENNOX AVE	91402	6	192B149   293	2638022011	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Expired	09/07/2017 12:00:00 AM	ADDRESS	34.22289	-118.44607	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (30) Kyocera KU 265 Modules(1) PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18303	16041-10002-04260	7800 W WORLD WAY WEST	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	PIN	33.94153561	-118.3984113	CHECKING FOR CHANGES TO APPROVED SET OF PLANS. CHECKING DELTA 3 REVISIONS. ADDITION OF 9 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18304	18041-10000-42827	5201 N SAN FERNANDO ROAD WEST	90039	13	165B205    83	5593010017	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.14699	-118.2726	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18305	16041-10000-33430	1140 E PALMS BLVD	90291	11	111B149   628	4242012036	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Expired	09/12/2023 12:00:00 AM	ADDRESS	34.00067	-118.4566	PC FOR PV. SYSTEM SIZE IS 7.6KWAC.SINGLE FAMILY DWELING. SYSTEM INCLUDES 31 MODULES SC-265 INCLUDING OPTIMIZERS P300-ZEP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18306	19041-20001-30333	13642 N GLADSTONE AVE	91342	7	228B153   396	2503006005	A1-1-K, RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	ADDRESS	34.31994	-118.43984	Revisions to approved plans.  Change of system design from main breaker derate to 225A main panel upgrade.$0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.(((PV1. SYSTEM SIZE OF 11.88 KWDC AND 9KWAC. INSTALL (36) LG330N1C PANELS WITH (1) INVERTER (SOLIS-1P9K-4G-US).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18307	17041-20003-41458	1333 S BEVERLY GREEN DR 1-4	90035	5	129B165   130	4330004010	[Q]RD2-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			02/08/2019 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.05319	-118.40537	02-08-2019 Changes to an approved set of plans, Changes include addition of an EV Charger and sup-panel and relocate load, all changes to has been cluded as delta 1 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18308	17041-10000-11307	303 N MCDONALD AVE	90744	15	027B205   184	7417016900	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.7725	-118.27116	PC for energy, Outdoor Ttile-24. Removing HID fixutres and replace with new LED fixtures. Area: 9,590.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18309	19041-10000-44064	18814 W FAIRFIELD ROAD	91326	12	207B121   673	2728031027	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Issued	11/04/2019 12:00:00 AM	ADDRESS	34.26173	-118.54358	(E-PLAN)NEW ROOF-MOUNTED PV1 INSTALLATION WITH AN EXISTING200 AMPS SERVICE. INSTALLATION INCLUDES 39 MODULES (LG350N1C-V5), 39 MICROINVERTERS (Enphase IQ), AND  1 COMBINER BOX.SYSTEM SIZE: 13.65 KW DC; 9.36 KW AC*NOTE: MAIN BREAKER DERATING WILL BE ON SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18310	16041-20000-19773	6715 N ENSIGN AVE	91606	2	180B173   168	2319017014	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Expired	07/10/2018 12:00:00 AM	ADDRESS	34.19252	-118.37151	PV1.  Install 6.6 kW roof-mounted PV system.  (17) modules with (1) 3 kW and (1) 3.6 kW central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18311	19041-10003-32003	9201 N OWENSMOUTH AVE	91311	12	198B105   144	2746012037	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.23757	-118.60203	"DELTA ""1"" CHANGES TO APPROVED PLANS. PLAN CHECK ONLY.(((PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 443 MODULES (SPR P17 330W), 222 OPTIMIZERS (P850 ), 2 INVERTERS ( SE 66.6K) SYSTEM SIZE IS 133.2KWac AND 146.2KWdc)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18312	10041-10001-00795	1601 S PERRINO PL # D	90023	14	118-5A219 167	5169015011	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/19/2010 12:00:00 AM			PC Approved	03/19/2010 12:00:00 AM	ADDRESS	34.02019	-118.2225	INSTALLATION OF 2X4 FLUORESCENT LUMINAIRES IN A WAREHOUSEPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18313	12041-10000-27845	4849 W SANTA MONICA BLVD	90029	13	144B197   716	5540024024	[Q]C2-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.09103	-118.29465	PV2 36KW ROOF-MOUNT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18314	19041-20000-37049	11211 N SEPULVEDA BLVD lot #44	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	08/09/2021 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 4.09 KW DC ROOF MOUNTED PV SYSTEM WITH (13) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18315	15041-10000-01072	12534 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	33.97822	-118.412	Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant).Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18316	16041-20000-38672	7858 W DENIVELLE ROAD	91040	7	210B193   241	2552013012	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.27226	-118.30459	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17.6KW$0 permit fee is due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18317	16041-20000-35606	7130 N ATHELING WAY	91307	12	183B093   245	2028018008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.19857	-118.63375	pv1install roof mounted pv system sized 6.6kw interconnecte d with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18318	16041-20000-41556	10309 W OLYMPIC BLVD	90064	5	129B161    58	4319005072	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.05271	-118.41729	Outdoor lighting retrofit for supermarket.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18319	11041-10000-18921	1630 N NORTH MAIN ST Bldg #7-3rd fl	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.06682	-118.22728	Plan check T-24 Energy (general/emergency) lighting on 1st floor LADWP General Services Headquarters (Bldg 7)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18320	14041-20000-17080	6220 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	34.1841	-118.60553	TI for a health club of 47,117 SQ feet on a new two stories of 89,882 SQ feet shell building. due to building submittal, PC in accordance to 2008 building efficiency standards. PART OF WESTFIELD VILLAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18321	14041-10000-01225	1458 S SAN PEDRO ST # 131	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK IS INDOORS. 816 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18322	18041-10000-42602	7722 W MELROSE AVE	90046	5	141B177   626	5527022027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.08355	-118.35817	CHANGE OF USE FOR RETAIL SPACE APPROXIMATLY 4000SQFT TITLE 24 ONLY WITH 100 AMP NEW PANEL SCOPE OF WORK INCLUDES LIGHTING AND HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18323	19041-10000-46735	720 W WASHINGTON BLVD	90015	1	124-5A203 127	5124034005	C2-1-O-HPOZ-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Apartment			11/13/2019 12:00:00 AM	09/04/2020 12:00:00 AM		Permit Finaled	01/03/2023 12:00:00 AM	ADDRESS	34.03555	-118.2752	APPLICATION 1 OF 2: FULL PC FOR A NEW 2000A SERVICE THAT SUBFEEDS A 2000A SWITCHBOARD THAT FEEDS A 800 HOUSE PANEL WITH ALL ASSOCIATED HOUSE LOADS. THE 2000A SWITCHBOARD THEN SUBFEEDS FIVE 600A METER SECTIONS WHICH SUBFEEDS VARIOUS SUBPANELS. TOTAL AFFECTED AREA IS 48,525 SFQT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18324	10041-20000-11114	19950 W RINALDI ST #101	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			06/11/2010 12:00:00 AM			PC Approved	06/11/2010 12:00:00 AM	ADDRESS	34.27535	-118.56939	revise secondary of transformer add fusible disconnect and reduce the wire size	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18325	19041-10000-21568	7132 W FOOTHILL BLVD	91042	7	202-5A199 597	2564001015	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.24792	-118.28712	Energy plan check for an INTERIOR T. I. TO (E) RETAIL STORE. Scope includes new lighting and equipment with a total lighting area of 1873-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18326	19041-20000-12869	12809 W LANDALE ST	91604	2	165B161    47	2362016013	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.15193	-118.41167	new 800 amp service to feed (4) existing sfds.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18327	15041-20000-19153	11119-11123 W BURBANK BLVD	91601	2	174B173   942	2337031022	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.17232	-118.37324	Plan check for power only. Project site is an existing commercial building. Building has (3) tenant spaces, each with its own address (11119, 11121, and 11123 Burbank Blvd). Project scope is a 600-amp service upgrade, the installation of (3) tenant panels, and (1) A/C unit for each. Title 24 is NOT part of this plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18328	12041-10000-19094	14708 W VENTURA BLVD SUITE B	91403	5	166-5A149  86	2276002030	C2-1L, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.15154	-118.45347	PLAN CHECK POWER AND ENERGY FOR CHIPOTLE RESTAURANT TI. A2 OCCUPANCY. EXISTING 2000A SERVICE SUPPLYING BUILDING. CURRENTLY NO TENANT THRU OUT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18329	13041-20000-33759	806 W ADAMS BLVD	90007	9	123A201   233	5123003022	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			PC Approved	12/04/2013 12:00:00 AM	ADDRESS	34.02974	-118.28024	T24 FOR EXISTING OFFICE SPACE. RETROFITTING LIGHTS AND RECONNECTING TO EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18330	19041-10000-37534	18400 W BURBANK BLVD	91356	3	174B125   488	2160010037	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	11/30/2023 12:00:00 AM	PIN	34.17045874	-118.53384937	PC for T24 Signs, building permit has been approved under 19048-10000-01622 and 19048-10000-01621	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18331	15041-20001-27689	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			Reviewed by Supervisor	09/04/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18332	15041-10000-03974	608 N SERRANO AVE	90004	13	141B193   845	5521004013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Expired	03/07/2017 12:00:00 AM	ADDRESS	34.08208	-118.30679	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (31) modules, (1) inverter, and (1) load center. There are 3 strings, 2 of which are being combined.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18333	16041-10000-44383	4448 N WESTCHESTER DR	91364	3	166-5A111  44	2174013026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.15159	-118.58394	PC FOR PV SYSTEM ROOF MOUNTED - USING 48 MODULES IN TOTAL - AC MODULES. RATED 16.5 KW AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18334	19041-10000-48989	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	PLAN CHECK FOR TITLE 24. TOTAL SQUARE FOOTAGE: 465 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18335	18041-20000-45842	2396 N BUCKINGHAM LANE pv1	90077	5	153B141   192	4377047001	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.11367	-118.47647	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.(2) tesla battery(1) load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18336	18041-10000-40655	9206 N PETIT AVE	91343	12	198B137   729	2687018011	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.23786	-118.49779	Plan check for a 6kw AC roofmounted system with (18) modules, and (1) central inverter interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18337	13041-10000-04804	5900 W WILSHIRE BLVD 11TH FLOOR	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	MODIFICATIONS TO APPROVED SET OF PLANS. REPLACEMENT OF SHEETS 401 and 701 from Plan Check Number 12041-10000-30390, TITLE 24 LTG FORMS ARE ON  ORIGINAL PLAN CHECK NUMBER, LIGHTING CONTROLS AND LUMINAIRE COUNTS TO REMAIN THE SAME. CHANGES ARE ONLY TO EMERGENCY LIGHT DESIGNATIONS .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18338	15041-10001-01075	12526 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.97833	-118.41207	(3/3/2015) CHANGES TO AN APPROVED SET OF PLANS.  CHANGE FROM UNDERGROUND SERVICE TO OVERHEAD SERVICE.  DELTA ONE REFLECT THE CHANGES DONE ON THE PLANS.Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps. Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18339	16041-10000-08280	10100 N GLENOAKS BLVD	91352	6	204B169    96	2528008900	OS-1XL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.25397	-118.39166	PC FOR POWER. INSTALL ELECTRIC SERVICE FOR NEW MOTOR OPERATED VALVE AND ASSOCIATEDCONTROL EQUIPMENT. HAZARDOUS AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18340	16041-10000-04990	9947 N BARTEE AVE	91331	6	201B153    63	2645009013	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.25106	-118.43295	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.2KWac.(20)MODULES-STANDARD(1)INVERTERS- ABB # PVI-4.2-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18341	11041-20001-01594	15853 W MONTE ST	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.31022	-118.47637	Revision delta 2 plan check only. Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18342	18041-20000-40041	5670 W WILSHIRE BLVD ste 1370	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Expired	02/25/2020 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18343	13041-20000-25306	2606 W AVENUE 30	90065	1	150B213   350	5457007029	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.10915	-118.24074	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.6KWAC USING 17 MODULES. TRANSFORMWERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18344	19041-10000-00355	1606 S LA CIENEGA BLVD	90035	10	129B173   937	5068007027	C2-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.04871	-118.37594	PLAN CHECK FOR TITEL 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18345	11041-10000-20655	1403-1407 S ELKGROVE CIR BLDG 8	90291	11	111B145   666	4243002069	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.00106	-118.45876	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18346	13041-10000-17779	2109 1/2 W CAMBRIDGE ST	90006	10	126B193   130	5074007013	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Apartment			07/05/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.04466	-118.30301	PV1 2.94kw XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [ 1INV: POWERONE PV-3.6-OUT-S-US-Z ] [ 12MOD: TRINA TSM-245PC05.18}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18347	19041-20000-53278	8635 W 3RD ST SUITE#1170	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.07373	-118.38073	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. TOTAL SQ. FT. 1674.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18348	17041-20000-17091	14241 W GILMORE ST 1-10	91401	2	180B153   879	2237021020	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			05/22/2017 12:00:00 AM			PC Info Complete	07/11/2018 12:00:00 AM	ADDRESS	34.18777	-118.44367	Plan check for power and energy. New 10-unit 2 story apartment building. 800A service. 13,000sqft.Building permit # 16010-20000-01923	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18349	15041-20000-13958	1801 W OLYMPIC BLVD 4TH FLR	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.05046	-118.27663	TI TO 4TH FLOOR TENANT. NEW LIGHTING. PC FOR T24 ENERGY ONLY. permit issued under this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18350	17041-10000-00387	7157 WORLD WAY WEST F/A	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	11/17/2020 12:00:00 AM	ADDRESS	33.94331	-118.4195	Plan check for new fire alarm system new substation. Total fire alarm devices: 22 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18351	19041-10000-34308	24311 W HATTERAS ST	91367	3	174B089   200	2046003034	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.17475	-118.65497	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 34 MODULES USIGN P320 OPTIMIZERS CONNECTED TO NEW 225A SERVICE MAIN PANEL UPGRADE SHALL BE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18352	18041-20001-22809	1251 W PACIFIC COAST HWY	90744	15	036B201   708	7414023024	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/29/2018 12:00:00 AM	ADDRESS	33.79053	-118.27919	Expedite per applicant request Plan check for PV roof mounted system, system size: 90kWac with 264 modules with 6 inverters(15kW) installed on commercial roof top connected supply side tap.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18353	13041-20000-32201	12989 N NORRIS AVE	91342	7	222B149   518	2506013005	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.30542	-118.45739	Modification to previously approved set of plans to correct the existing main panel size only.        <<<PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.82KW. 14 MODULES AND 1 INVERTER>>>	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18354	15041-20001-39676	11915 W WICKS ST	91352	6	195B165     9	2631004084	[T][Q]M1-1, [T][Q]P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.23478	-118.39294	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 31.36 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18355	14041-20000-15924	400 W 30TH ST	90007	9	120A203    86	5122018033	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.02393	-118.27577	TI to (E) single-story office building data center.  Optional standby UPS system installed to serve data room.  Plan check for Title 24 for changes to lighting system. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18356	18041-10000-32293	2035 N HILLHURST AVE	90027	4	150B197   362	5590007036	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.10865	-118.28759	TI of an existing Albertsons Grocery Store. 29,119 SF.Title 24 - Energy Calcs.18016-40000-27056	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18357	16041-30001-04517	905 S LE DOUX ROAD	90035	5	132B173   177	4333022013	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			05/21/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.06069	-118.37752	05/21/2019 Changes to an approved set of plans. All changes have been clouded and marked Delta 2. Changes have been made to the single line diagram to reflect field installation and relocation of loads. *****Original Work Description*****Plan check for New 5 story 21 units appartment building. Service size: 1,600A Total area: 16,503 sq ft.Note: Building permit has been issued under 15010-30000-00015	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18358	17041-20000-21076	11845 W OLYMPIC BLVD #515	90064	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.03291	-118.45177	Plan check for energy only. TI to office suite 515W in high rise building. New lighting (incl. emergency) - 1,474sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18359	15041-10001-29082	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM			PC Approved	01/12/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	Supplemental plan check on an approved plan. Change on lighting fixture (Removed F3),  convert restroom to electrical room, relocate (E) panel A. Permit under 15041-10000-29082***TI for an existing commercial build. adding new lights, control ,new panel, newly connected load < 400 A.PC for Energy only. Total area: 1012 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18360	13041-10000-02766	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			Verifications in Progress	04/11/2013 12:00:00 AM	ADDRESS	34.01925	-118.37654	FULL PC FOR POWER. existing building. no lighting changes. replacing pumps, adding chillers, switchboard (1600A) , adding 150kva redundancy module for UPS. methane buffer zone - no underground work per applicant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18361	18041-10004-15820	20209 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM			Permit Closed	05/21/2019 12:00:00 AM	ADDRESS	34.27509	-118.57388	DELTA 10 REVISIONS TO PERMITTED SET OF PLANS ; LIST OF CHANGES ARE ATTACHED TO REVISED SET OF PLANS ((((((FULL PC FOR WHOLE FOODS MARKET BUILDOUT (41,00SF) TO EXISTING CORE AND SHELL RETAIL BUILDING WITH 1 LEVEL MEZZANINE. SCOPE OF WORK INCLUDES NEW CIRCUITS AND PANELS. TOTAL SQ. FT. 42517.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18362	14041-10001-07248	4150 W PICO BLVD	90019	10	129B189   965	5072005010	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.04756	-118.32583	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. 720 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18363	11041-10001-08431	7648 N CLYBOURN AVE	91352	2	186B177   576	2466029049	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM			PC Approved	12/09/2011 12:00:00 AM	ADDRESS	34.20933	-118.36317	REVISION TO APPROVED PLANS. REVISION INCLUDES REMOVAL OF TIME CLOCK, PROVIDE OCCUPANCY SENSORS THRU OUT BUILDING, PANEL A1 FEEDER SYSTEM EXISTING TO REMAIN, RELOCATE TWO A/C FROM PANEL B TO PANEL A1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18364	11041-10000-20132	15503 W VENTURA BLVD	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM			PC Approved	09/21/2011 12:00:00 AM	ADDRESS	34.15504	-118.4723	T.I. to an existing office building on the 2nd floor, suite 240.  Plan check only for energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18365	18041-10000-35045	600 W 7TH ST SUITE 360	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.04728	-118.25685	T.I. TO EXISTING DATA CENTER; on the 3rd floor.NEW SWITCHGEARS, UPS, BATTERIES, TRANSFORMERS, PANELS, CIRCUITS, T-24.Bulding Permit: 18016-10000-29632	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18366	16041-10001-45417	1122 W WASHINGTON BLVD	90015	1	126A201   241	5135014042	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.03877	-118.28233	PC FOR CHANGES TO APPROVED SET OF PLANS. CHECKING FOR PERFORMANCE APPROACH FOR ENERGY COMPLIANCE. CHANGE NOTED DELTA 2 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18367	14041-10000-11912	750 N VINE ST	90038	13	141B189   183	5534034028	[Q]C2-2D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.08471	-118.32642	Plan check for energy only. TI IN AN EXISTING RESTAURANT. SUBWAYS. 1 STORY.  Permit for a new panel and circuits was issued under 14041-40000-12695. This permit is for installing lights and exit signs on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18368	15041-20001-33187	4918 N LOCKHAVEN AVE	90041	14	162A219   213	5683027008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.13827	-118.22351	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (24) modules, (24) micro-inverters, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18369	09041-20002-17383	10321 N SEPULVEDA BLVD	91345	7	204B145   114	2649018001	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1097.00	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.25857	-118.46768	revise PPROVED PLANS FOR ENERGY CALCULATIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18370	12041-10000-01370	2121 S AVENUE OF THE STARS C-Store	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	01/19/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check T24 Energy for retail store on the ground level.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18371	15041-10000-26639	2310 N APOLLO DR	90046	4	153B177   463	5569008027	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	03/05/2016 12:00:00 AM	ADDRESS	34.11295	-118.36424	PV1, INSTALL NEW 17.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(66) MODULES: KYOCERA KU2606XPA(2) FRONIUS IG PLUS A 7.5    (((((((((     permit fees waved due t senate bill 1222        2012    ))))))))) mz	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18372	14041-20000-03461	15633 W LUDLOW ST	91344	12	210B141   652	2662014015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Expired	03/02/2016 12:00:00 AM	ADDRESS	34.27106	-118.4729	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18373	19041-10000-52958	7687 W FOOTHILL BLVD	91042	7	204B197   673	2558008017	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.25691	-118.30017	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 (OUTDOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18374	14041-20000-06262	14520 W FOX ST	91345	7	210B149  1129	2615026***	(Q)RD6-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.26911	-118.44921	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan. using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18375	12041-20000-10651	16255 W VENTURA BLVD #300	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.15711	-118.48768	s.300 office t.i.Energy onlyexist. permit 12041-30000-09143	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18376	16041-20000-01195	7015 N JELLICO AVE	91406	6	183B129   505	2228023010	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.19792	-118.51752	Install a roof mounted solar array on a SFD. Interconnect with a 100A MSP.System size: 3kW. Ungrounded system. (14) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18377	17041-20001-11182	15206 W ROXFORD ST	91342	7	228B145   470	2501020036	C1-1VL-K-CPIO	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.31803	-118.46363	02/01/2018 Changes to an approved set of plans. All changes have been clouded. Shopping center has changed from a 7-tenant building to a 6-tenant building. Building footprint has changed. Location of utility transformer and electrical distribution equipment has changed. Lighting floor plan changes have been made to reflect the change of building footprint.THIS IS PLAN CHECK ONLY.  Note: Building application for the revision has been done under 17010-20001-01382*****Previous Work Description*****Plan check for power and energy. Project site is a new shopping center complex. Project scope is the core and shell. Work includes a new 800-amp service and a total lighting area of 16,750 sq. ft.Note: Building application has been created under 17010-20000-01382	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18378	13041-10002-07977	222-234 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.05621	-118.25318	Change to approved set by rerouting the feeder to emergency panel and fire pump system, changing fire pump cable and readjusting feeder to proper size. Note fire pump cable shall be under RHW-two hour Fire Resistive cable. Per M.Z(((Remove gas generators and install two diesel generators rated 650 KW.  Reconnect powers to two existing fire pumps.  Install two new dedicated services (1000A each) for fire pumps.  Plan check for power only.  Location in Methane Buffer Zone. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18379	18041-20000-07238	2036 W RIDGEVIEW AVE	90041	14	159A223   104	5685024038	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.13093	-118.21214	pv1install roof mounted pv system sized 6.6kw interconnected with msp.(1) tesla power wall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18380	11041-10000-16831	2914 W 8TH ST	90005	1	132B197   497	5077023015	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.05751	-118.28966	NEW 85-UNIT, 5-STORY APARTMENT COMPLEX WITH 2-LEVEL UNDERGROUND PARKING.  PLAN CHECK FOR POWER AND ENERGY.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18381	17041-10000-28363	808 N LILLIAN WAY	90038	13	141B185   151	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.08566	-118.32757	FULL PC FOR POWER AND ENERGY FOR A NEW PARKING STRUCTURE WITH ONE PARTIAL SUBTERRANEAN LEVEL AND THREE LEVELS ABOVE GRADE. SCOPE INCLUDES A NEW 800A 277/480V 3 PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS, AND NEW LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA IS 103205 SQ. FT. B#17010-10000-02975	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18382	19041-10000-47404	1083 S GAYLEY AVE 1SF FLOOR	90024	5	132B149    93	4363025002	C4-2D-O	West Los Angeles	Westwood	North Westwood		2653.05	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.06052	-118.44696	GROUND FLOOR INTERIOR TENANT IMPROVEMENT , INSTALL NEW luminaires and lighting fixture controls in the dining anf kitchen of an existing restaurantPLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18383	14041-20001-25454	21301 W BURBANK BLVD 2ND FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	34.17351	-118.59524	11/12/2014 - Changes to approved set. Changes clouded. Change lighting fixtures and fixture counts.[TI FOR FULL 2ND FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18384	15041-10000-41782	7317 W BEVERLY BLVD	90036	5	138B181   388	5526036016	C2-1VL-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.07632	-118.34918	APP # 16041 90000 14459 WAS FOR GENERGAL TI. 5/12/16: Submittal 2, adding outdoor dining lights, revise light fixture wattage.<<PC FOR ENERGY ONLY FOR EXISTING RESTAURANT.>>THIS PERMIT SHALL BE FOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18385	15041-20000-42666	15980 W FILBERT ST	91342	7	228B141    43	2582033046	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.32506	-118.48304	Plan check for PV roof mounted system. System size: 7.0kWac with 22 moduels and 1 inverter(7.0kW). Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18386	13041-10000-15895	1901 1/2 S BUNDY DR	90025	11	123B149   379	4259019012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.03435	-118.45789	CONSTRUCTION OF NEW 550 SF BICYCLE STORAGE AND MAINTENANCE FACILITYPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18387	17041-20000-36386	15535 W VINCENNES ST	91343	7	198B145    95	2656015012	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Re-Activate Permit	11/01/2019 12:00:00 AM	ADDRESS	34.24107	-118.47086	ENERGY STORAGE SYSTEM. 13.5 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18388	16041-10001-17965	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	ADDRESS	34.03474	-118.24063	PC ONLY FOR T-24, PERMIT UNDER 16041-10000-17965.   INSTALL OUTDOOR LANDSCAPE LIGHTING, TOTAL AREA 12,179 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18389	19041-10000-25633	7850 N HANNA AVE	91304	3	189B101   542	2012013017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Issued	07/03/2019 12:00:00 AM	ADDRESS	34.21337	-118.60701	pc for pv-1, 16 modules with microinverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18390	14041-20000-29618	1328 N LAKE SHORE AVE	90026	13	141A209   458	5419031011	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	34.07887	-118.25979	Change of use from Photo Studio to Retail.  Install general/emergency indoor/outdoor lighting.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18391	19041-10000-16092	4037 S TIVOLI AVE	90066	11	108B153   578	4230009032	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM			Corrections Issued	05/23/2019 12:00:00 AM	ADDRESS	33.9927	-118.44075	PC FOR PV-1. SYSTEM SIZE IS 8.320KW CONSISTS OF (26)MODULES (LR6-60) W/320P SOLAREDGE OPTIMIZERS AND (1) CENTRAL INVERTER(SOLAREDGE 7600H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18392	15041-10000-29613	4720 E HUNTINGTON DR SOUT	90032	14	142-5A231  98	5213019014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	PIN	34.08526511	-118.18236534	PC FOR ENERGY ONLY, TO AN (E) BUILDING.TI CHANGE OF USE FROM A BAR TO RETAIL. SCOPE INCLUDES NEW LITHING. TOTAL SQ FT. 2190. FEES WERE PAID UNDER APPLICATION# 15041-10000-27367	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18393	11041-10000-15894	5072 S SLAUSON AVE	90230	11	108B161  1180	4217029903	OS-1XL, R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.00	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	33.99368	-118.40672	Fire alarm system for new single story multipurpose Bldg to be supplied by buildings electrical service.  See application number 11041-10000-09172.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18394	18041-10000-29193	21301 W VENTURA BLVD	91364	3	171B105    15	2167001019	(T)(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.16775	-118.59595	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18395	17041-10001-25303	1441 E BOYD ST	90033	14	127-5A219 118	5172018014	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.04445	-118.22484	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO LIGHTING LAYOUT. REVISED LAYOUT AND FIXTURE TYPE. UPDATED PLAN AND T24 CALCS PC ONLY. PERMIT ALREADY ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18396	19041-20000-49594	5114 N SHOSHONE AVE	91316	5	171B129   236	2257004039	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.16439	-118.51615	Plan check for PV roof mounted system, PV system size: 10KW AC, 11.34KW DC with 36 PV modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18397	11041-10000-10029	4900 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	09/15/2011 12:00:00 AM	ADDRESS	34.09786	-118.29626	Provide power for new UPS for local area network up grade, new xfmr , receptacle and panel boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18398	13041-20001-29678	333 S GRAND AVE 9TH FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	changes to approved set of plans. changes only to T24. reduced scope of work to only cover bathrooms. clouded changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18399	13041-10000-34054	1038 S WESTWOOD BLVD	90024	5	132B153    52	4363020009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.0618	-118.44516	TI for Urban Outfitter's retail store in (E) 2-story building.  Newly connected load below 400A, plan check only for Title 24 lighting compliance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18400	14041-20000-15468	7868 N VAN NUYS BLVD	91402	6	189B149   644	2212028023	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.21394	-118.44777	Install new outdoor lighting for Hometown Buffet.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18401	14041-20001-14134	12631 W ADDISON ST	91607	2	171B161   925	2357008004	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.16137	-118.4084	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18402	12041-20000-05163	8413 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM			PC Info Complete	03/22/2012 12:00:00 AM	ADDRESS	34.22412	-118.62574	energy plan check 2nd and 3rd floor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18403	19041-10000-31947	3517 S SPEARING AVE	90732	15	009B189   300	7563025006	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.7217	-118.32324	0$ final fees per AB1414PV1, New rooftop mounted system, system size is 15.295KWdc/12.8KWac. Scope of work is solar roof tiles roughly 1374 sqft, 2 central inverters (Salivia 7.6 TL and Salivia 5.2 TL),three new load centers (200A ,70A,200A), and two ESS (Tesla Powerwall)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18404	13041-10000-29593	1221 S SIERRA BONITA AVE	90019	10	129B177   162	5085021035	R1-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.053	-118.35802	PV1.  Install 4.75 kW DC roof-mounted solar array, interconnect with main service panel.  Located in methane zone. Transformerless inverter: SolarEdge SE5000A-US.  19 modules: Hanwha Hsl60p6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18405	13041-20000-22068	2035 N HIGHLAND AVE PV-2	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.10759	-118.3376	PV-2. Commercial rooftop solar. 30kW AC system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18406	14041-10000-13648	10837 W VIA VERONA	90077	5	147B145   110	4377036005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.09906	-118.45924	PV1 7.344KWAC. 240V. microinverter. STD. 2story. Roofmount. [(34) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(34)modules: {LG EELECTRONICS LG270S1C-A3}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18407	16041-10000-26666	11159 N HERRICK AVE	91331	7	210B161   351	2534026022	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.27252	-118.41651	install new roof top solar pv1 on SFD, 3.8kw AC system. (1) solar edge SE3800A-US  (12) modules,  using power optimizer.*Inspector to verify physical location of the electrical equipments, it shall not obstruct the path of driveway*	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18408	17041-10000-43303	350 S GRAND AVE 51st &-52nd flr	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Info Complete	12/15/2017 12:00:00 AM	ADDRESS	34.05173	-118.2522	Energy plan check for (2) floor (51st and 52nd) located in a highrise building. Scope includes new light and equipment. Total area is 7,906 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18409	17041-20000-10027	6882 S ARIZONA AVE	90045	11	102B165   127	4110001028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	33.97776	-118.39577	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18410	13041-20000-16807	831 N PASEO MIRAMAR	90272	11	129B117    22	4416022066	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2013 12:00:00 AM	07/29/2013 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.04996	-118.5578	UPGRADE EXISTING SINGLE FAMILY DWELLING SERVICE TO 600A. FAULT CURRENT AND LOAD CALS FOR EXISTING LOADS PROVIDED. PLAN CHECK FOR POWER. NEW DISTRIBUTION BOARDS AND FIRE PUMP AHEAD OF MAIN. NEW GENERATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18411	16041-20000-41772	13631 N ELDRIDGE AVE	91342	7	228B157   789	2510007001	R1-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.3193	-118.42669	Plan check for installation of solar pv system, roof-mounted on a SFD. Interconnect with 200A MSP. Derating the main breaker to 175A. (N) 4.2kW ungrounded system, which is being added to an (E) 7.6kW ungrounded system. (N)(16) 315W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18412	15041-10000-31647	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Expired	01/10/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	RELOCATION OF AN EXISTING 250HP WELL PUMP IN A REFINERY.  NON HAZARDOUS LOCATION.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18413	17041-10000-39119	1147 N VINE ST	90038	13	144B185   522	5533007002	C2-1D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.09215	-118.3268	PLAN CHECK FOR T24 ONLY, INSTALL NEW LIGHTS AND RECEPTACLE (INTERIOR REMODEL)  AT 2ND FLOOR OF (E) OFFICE BUILDING, 1,160 SQ. FT(B# 17016-10000-31186)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18414	15041-20000-37496	9734 N KENTLAND AVE	91311	12	201B101   308	2727003026	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.24725	-118.61786	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (32) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18415	17041-10000-15711	5150 E HUNTINGTON DR SOUTH	90032	14	144A235   172	5219001034	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.08903	-118.17042	T24 ONLY. REPLACE EXISTING HID LIGHT FIXTLURES WITH NEW LED LIGHT FIXTURES. TOTAL ARE  A  20100 SQ FT. OUTDOOR  LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18416	10041-10000-25835	1059 S BROXTON AVE	90024	5	132B149    60	4363024006	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	01/13/2011 12:00:00 AM	ADDRESS	34.06142	-118.44645	TI in an existing restaurant. EPC is for Energy. (Permit was pulled)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18417	15041-10000-22906	3425 W MONT CLAIR ST	90018	10	123B189  1033	5052013016	RD5-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Expired	10/13/2017 12:00:00 AM	ADDRESS	34.02976	-118.32212	PV 2, MULTI UNIT APARTMENT. ROOF MOUNTED SYSTEM WITH (8) MODULES AND 1 -3.0KW INVERTER. TOTAL SIZE 2.12 KW. (8) KYOCERA #KU2656ZPA(1) PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18418	14041-20000-27327	9885 N TAMARACK AVE	91331	7	201B161   324	2624006016	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.24965	-118.40932	install roof mounted pv system sized 3.6kw interconnected with msp.(17) hyundai heavy industries m250 modules(17) enphase m215 inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18419	15041-10000-11386	624 S GRAND AVE	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	PIN	34.04778206	-118.25563275	T24 ONLY. REPLACEING SOME LIGHT FIXTURES NEW FLORESCENT FIXTURES. TOTAL AREA 673 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18420	17041-10002-11330	14401 W SATICOY ST	91405	2	186B149     7	2215001910	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Issued	08/09/2018 12:00:00 AM	ADDRESS	34.20855	-118.4479	Change to approved set by modifying the single line and floor plan. All main back feed power remain the same.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18421	17041-10000-03958	6000 W PICO BLVD	90035	10	129B173   338	5068011006	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.05223	-118.3713	PC for Fire Alarm with 40 Devices and 1 Fire Alarm panel. FA installed in one story educational building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18422	17041-10000-22340	9042 N SEPULVEDA BLVD	91343	7	195B145   655	2654004053	R3-1, [Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.23467	-118.46632	PC for T24 for TI in nail salon. PC for lights and receptacles. Total affected area 522 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18423	18041-10000-02488	515 S FLOWER ST #1150	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC FOR OFFICE TI IN  A HIGH RISE FOR  T-24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTING, EQUIPMENT AND RECEPTICALS. TOTAL AFFECTED AREA IS 3275 SQ.FTB# 17016-20000-37791	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18424	13041-10005-33082	1550 N EL CENTRO AVE	90028	13	148-5A189 331	5546026024	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.09961	-118.32359	6/24/16: Changes to an approved set of plans pertaining outdoor lights (2008 T-24 forms). Plans have been modified to reflect all to-date field changes. All changes have been clouded and marked Delta 5, 6, 7, 9,1107/14/2015 Changes to an approved set of plans. Plans have been modified to reflect all to-date field changes. All changes have been clouded and marked Delta 5, 6, 7, 8, 9, and 10.*****Previous Work Description*****CHANGE TO APPROVED SET OF PLANS. ADDITION OF A COUPLE NEW PANELS, UPGRADE TRANSFORMERS AND UPPER LEVELS, AND RELOCATION OF SOME LOADS. PLAN CHECK FOR POWER SYSTEM CHANGES. ALL CHANGES HAVE BEEN NOTED DELTA 3 AND DELTA 4.*****Original Work Description*****PC FOR POWER AND ENERGY. PER BUILDING, COMMON PARKING, SINGLE STRUCTURE. 4 ADDRESSES.PLAN CHECK HOURS CHARGED DUE TO GLITCH IN PCIS. THEY ARE EQUIVELENT TO 213000 SQRFT OF TITLE 24 PLAN CHECK. TOTAL SQRFT FOR T24 IS 1,117,551 SQRFT. TOTAL PRICE OF SUBMITTAL IS ABOUT $60K*****Building Permit Description*****New Below-Grade 5-level Parking Garage:  590,000 SF S-2 occupancy including B occupancy in accessory spaces (parking management office, building security office, etc.)New Six-Story Office Buildings:  10,150 SF A-2 occupancy (restaurant); 13,500 SF A-3 occupancy (fitness); 306,550 SF B occupancy (office); 2,100 SF M occupancy (retail)New Two-Story Office Building: 10,150 SF B occupancy (office)Future High-Rise Residential Tower: 1,800 SF A-2 occupancy (restaurant); 700 SF B occupancy (office); 6,000 SF M occupancy (retail); 245,600 SF R-2 occupancy (apartments)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18425	12041-20000-29534	3654 S TILDEN AVE	90034	11	117B161   685	4252012031	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.0169	-118.41682	solar single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18426	14041-10000-17156	1818 S SEPULVEDA BLVD	90025	5	129B153  1089	4323021039	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.04583	-118.44246	plan check for power and energy only. (e) service. BLDG#14014 30 00946: Alteration to existing 3 story existing office building with full interior remodel.  RESTRIPING PARKING TO ADD 1 H/C PKG SPACE AND RELOCATE 1 H/C PKG SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18427	13041-20000-20058	9635 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.24571	-118.5363	"Change of use from retail to restaurant.  Load is less than 400 amps.  Occupancy load is 49 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  PERMIT FEES ARE UNDER INSPECTION.      ""COMPLY WITH DEPARTMENT ORDER effective date 06/26/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18428	15041-30000-35971	7306 S WESTERN AVE	90047	8	102B193  1606	6018001008	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	03/08/2017 12:00:00 AM		Issued	03/08/2017 12:00:00 AM	ADDRESS	33.97344	-118.30877	Title 24 plan check only.   Total area = 10,457 sq. ft. (indoor) + 8,286 sq. ft. (outdoor).     T.I. to existing retail space (Family Dollar Store).  New switchgear and subpanels with associated lighting, HVAC, and equipment loads.  Existing 400 A service to be used (new meter).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18429	17041-10000-32657	5711 S HOLMES AVE	90058	9	108B213   530	5105022003	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	33.99085	-118.24135	PC FOR SERVICE UPGRADE SERVICE SIZE 800A 120/240V.SCOPE INCLUDES SERVICE UPGRADE ONLY.  ALL OTHER PANELS TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18430	12041-20000-13252	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Refund in Progress	11/09/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. of the retail space #1214. Install general/emergency lighting with Tailor Method.  Plan check for energy. No track lighting is used only one spot fixtures, 1.0 fc at eagress is maintained	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18431	18041-10000-22725	14850 W BURBANK BLVD	91411	4	174B149   867	2249028017	[T][Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.17189	-118.45716	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18432	13041-20000-06766	22352 W LULL ST	91307	3	186B101   140	2012020049	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	PIN	34.20853471	-118.61423474	Photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18433	11041-10000-05574	845 S FIGUEROA ST	90017	9	129A207   195	5144022036	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.04698	-118.26234	5-STORY COMMERCIAL BUILDING WITH A MECHANICAL PENTHOUSE.  GUTTED BUILDING FROM THE SERVICE UP.  WILL USE EXISTING SERVICE, MOST EVERYTHING ELSE IS NEW.  FLOW AND TAMPER DIALER IN BASEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18434	14041-10001-10503	2667 N PIRTLE ST	90039	13	147A213    99	5442011015	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.09801	-118.24423	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE # SE6000A-US-ZB-U(26)MODULES: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18435	19041-10000-39400	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.06371	-118.2982	T-24 PLAN CHECK FOR A TI TO EXISTING RESTAURANT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 2345 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18436	16041-10001-12199	350 S GRAND AVE 45TH FL	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	T-24 PC FOR ENERGY AND EMERGENCY LIGHTING TO A HIGH RISE CORRIDOR.  SCOPE OF WORK INCLUDES NEW LIGHTING IN THE CORRIDOR. TOTAL SQ. FT. 1502. INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT 16041-10000-12199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18437	13041-10000-07709	621 S WESTERN AVE # 204	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TENANT IN RETAIL SPACEFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18438	13041-10000-14535	5837 S CENTRAL AVE	90001	9	108B209  1458	6007003900	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	33.98881	-118.25673	NEW BLDG CONSTRUCTION OF A CVS STORE. PLAN CHECK FOR POWER AND ENERGY. INDOOR LIGHTING IS 14896 AND OUTDOOR LIGHTING OF 17337. PROJECT LOCATED IN A METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18439	11041-10000-20723	429 N WESTERN AVE	90004	4	141B193  1425	5522019025	C2-1	Central	Wilshire			1924.20, 1925.10	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	09/28/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.07894	-118.30933	alterations in a T-MOBILE retail storeplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18440	19041-20000-12664	10252 N TUNNEY AVE	91324	12	204B117   203	2726016001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.25689	-118.55782	Installation of 13.5 kWh energy storage system and associated distribution/critical load panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18441	10041-10001-24707	517 W 7TH ST	90014	9	129A209   142	5144004035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.04706	-118.25596	installed new 800A  swbd and service ; refurbished 4-stories building with  floors 1 thru 3 to be commercial tenants and the 4th fl to be a residence.plan chk is for  shell and core and the 4th fl residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18442	13041-20000-34287	8319 N LOUISE AVE	91325	12	192B133   237	2787020030	P-1VL, QC2-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			PC Approved	12/10/2013 12:00:00 AM	ADDRESS	34.22187	-118.51005	T24 FOR EXISTING RESTAURANT RECONNECTING LIGHTS TO EXISTING CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18443	11041-20000-07550	9001 N TAMPA AVE 103	91324	12	195B117    25	2783028013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM			PC Info Complete	04/14/2011 12:00:00 AM	ADDRESS	34.23383	-118.55386	Space 103.  This plan check only for the feeder only as requested per inspector Veral.  Original plan check was approved by number 10041-20000-01241 Revision dated 4/14/2011.  New tenant at this building need full plan check with verification of total load.  Again this plan check only for the feeder side and the protection of the feeder.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18444	12041-20000-27000	13306 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	PIN	34.31253789	-118.42511113	Enphase system on roof of single family dwelling..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18445	18041-10000-48989	2450 S LA CIENEGA BLVD	90034	10	123B173   223	5065022002	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2702.00	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.03576	-118.37759	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18446	15041-20001-01389	1045 W 46TH ST	90037	9	111B197   371	5017031013	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.00176	-118.29327	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.25 KW. (29) HYUNDAI HISM250(29) ENPHASE ENERGY M215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18447	14041-10000-10196	127 S ANITA AVE	90049	11	132B141   648	4405028006	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.05654	-118.48335	Install 6.25 kW DC roof-mounted solar array on a two-story house, interconnect with  main service panel. (1)Transformerless inverter: POWER-ONE # AURORA PV1-4.2-OUTD-S-US-Z-A(25) Modules: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18448	15041-10002-06912	6116 N RHODES AVE	91606	2	177B165   440	2333014031	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM			PC Approved	03/31/2015 12:00:00 AM	ADDRESS	34.18186	-118.40289	Supplemental plan check for a change in system size. System size is 6 kWac. System has gone from (18) modules to (13) modules. Standard plan is being used for the changed system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18449	16041-20000-18360	6600 N TOPANGA CANYON BLVD System B	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for PV carport ground mounted system in Topanga Mall Parking Lot. System size: 386kW with 1,701 modules and 11 inverters(33.3kW) and 1 inverters(20.0kW)This is system B part of larger system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18450	15041-20000-33972	15560 N LUCKY PL	91342	7	222B145   710	2604011059	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	PIN	34.30627997	-118.47128172	pv1 sfd. total system size 5kw ac using 18 modules total.system includes a pv monitoring circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18451	16041-20001-26567	10923-10929 W WEYBURN AVE	90024	5	135B149   586	4363018011	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Issued	08/09/2019 12:00:00 AM	ADDRESS	34.06274	-118.44623	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 6 ONLY. ADD POWER AND LIGHT FOR 2 RESTROOMS AND 1 OFFICE.<<<Plean check for power and energy. TI to an (E) commercial building.  Replace 2000A main switchboard to create multi metering system for future tenants. Install new 200 Distribution panel. Total affected area for energy is 1,118 sq.ft.  Service size remain the same (2000A)(B# 16016-10000-17446)>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18452	13041-10000-25331	8857 N GERALD AVE	91343	12	195B137   405	2688040001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.23182	-118.49495	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION IN A SINGLE-STORY HOUSE. SYSTEM SIZE IS 10KW DC IN 2 STRING. DERATING 200A EXISTING MAIN BREAKER TO A NEW 175A BREAKER. LOAD CENTER IS USED.(40) MODULES: REC SOLAR REC250PE(2) INVERTERS: SUNNYBOY SB7000US(240V) , SUNNYBOY SB3000HFUS-30(240V)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18453	13041-10001-33095	23016 W VANOWEN ST	91307	12	180B097    19	2038019002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.19354	-118.62838	Expedited RSES  plan check per applicant request.[][][][]PV1, Install 6.5 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE6000A-US. 26 modules TRINA SOLAR TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18454	19041-10000-32155	1800 W BEVERLY BLVD	90057	13	135A205   319	5154001019	C2-1, R4-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	08/11/2021 12:00:00 AM		Issued	08/11/2021 12:00:00 AM	ADDRESS	34.06495	-118.26724	Full Plan Check for a methane mitigation system in a mixed use building (retail and apartments), scope of work includes a new panel and 29 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18455	17041-20005-43118	269 S MARIPOSA AVE	90004	10	135B197   154	5518007026	C2-1, R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.06948	-118.29938	plan checking only. change to an approved set . D-delta change.  removing electric range. and changing MSA3 and MSA4 feeders as well as some of the unit feeders	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18456	12041-10000-21885	6041 W CADILLAC AVE	90034	10	126B173   862	5066002026	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.03806	-118.37594	Plan check power exam rooms TI on the third floor.  Kaiser medical office building. New panel, branch circuits.  Plan check for power only.Note:  Energy plan check under a separate application 12041-10001-21885	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18457	13041-10000-28431	12304 W SANTA MONICA BLVD # 117	90025	11	126B145   865	4267031001	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.03925	-118.46584	TITLE-24 ENERGY PLAN CHECK FOR EXISTING COMMERCIAL BUILDING. T.I. IS FOR OFFICE SPACE. TOTAL AREA TO BE 1314 SQ FT. EXISTING PERMIT UNDER 13041-10000-25837	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18458	09041-10004-11227	2600 W WILSHIRE BLVD	90057	1	133-5A201 122	5141008900	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	01/05/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.06041	-118.28167	relocate a 30 H.P transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18459	11041-20000-09305	3278 N CAHUENGA BLVD WEST	90068	4	159B181   575	2429009002	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM	05/06/2011 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.13011	-118.34934	New addition to existing building.   Install general/emergency lighting.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18460	19041-20000-31078	21031 W VENTURA BLVD #1100	91364	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.16693	-118.5916	Plan check for Title 24 in existing space Tenant Improvement office space. Total area: 3475 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18461	15041-20005-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.25734	-118.50614	8/30/2017changes to an approved set of plans.  changes noted delta 3 only.  changes include updated SLD to reflect field conditions and addition of water heater.  (((Changes to approved set of plans. changes noted (delta 6/12/17).  changes to reflect field conditions.  this is plan check only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18462	19041-10000-51168	379 N KENTER AVE	90049	11	135B141   544	4403005014	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.06527	-118.48403	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 7.6KWac/9.9KWdc. SCOPE OF WORK IS 32 NODULES (HANWHA 310) WITH OPTIMZERS (SEP 340) AND A CENTRAL INVERTER (SE7600H-US). NO MPU.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18463	12041-10000-18917	326 W 23RD ST	90007	9	123A205   188	5126018035	(T)(Q)C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.02929	-118.27151	PLAN CHECK POWER AND ENERGY FOR A FIRST TIME TENANT MEDICAL CLINIC IN A NEW MIXED USE BUILDING. NEW FEEDER FROM EXISTING DISTRIBUTION TO CLINIC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18464	17041-10003-09168	6904 S LA TIJERA BLVD	90045	11	102B173   202	4103010004	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	33.97579	-118.37323	PC FOR POWER DUE TO UPGRADED SWITCH BOARD (600A)SCOPE INCLUDES NEW PANELS,  HVAC, AND CIRCUITS.USING EXISITING SERVICE. NO CHANGES TO TITLE-24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18465	19041-20000-16695	22135 W ROSCOE BLVD LOT #39	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PV1.  Install 2.1 kW roof mounted grid tied PV system.  (7) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18466	17041-20000-42941	1547 W VENICE BLVD	90006	1	126B197   133	5056006021	CM-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.04438	-118.28786	PLANCHECK FOR POWER AND ENERGY. NEW SERVICE AND REPAIR DUE TO FIRE DAMAGE. BUILDING PERMIT: 17016-20000-18276 , 17016-20001-18276	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18467	16041-10000-31993	12944 N BORDEN AVE	91342	7	222B153   924	2509006088	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.3052	-118.44001	PV1. Mew roof mounted pv system using 21 modules and 21 microinverter enphase m215. Total system size is 4.515KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18468	17041-10000-19302	380-384 WORLD WAY MSC-F/A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	New Fire alarm system at the Midfield Satellite Concourse of LAX. (135) panels,  (5309) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18469	16041-20000-44587	10752 N WYSTONE AVE	91326	12	207B121   207	2718014022	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.26612	-118.54733	PV1.  Install roof mounted grid tied PV system.  (35) modules with Enphase M250 microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18470	19041-10000-40994	526 S SAN JULIAN ST	90013	14	127-5A213 271	5148012012	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/16/2019 12:00:00 AM	ADDRESS	34.04375	-118.24536	PC FOR A NEW FIRE ALARM SYSTEM IN A COMMERCIAL SPACE (HOMELESS SHELTER). TOTAL NUMBER OF DEVICES 10 WITH A NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18471	12041-10000-19364	1025 N HIGHLAND AVE 7th Floor	90038	4	144B185   830	5532028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.08969	-118.33884	Change to lighting  for an existing storage space on the 7th floor of a high-rise building.  Load is less than 400Amps.  PLAN CHECK ONLY for Energy.  Emergency lighting is all existing per applicant.  Emergency lighting is NOT part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18472	16041-20000-09233	13604 W SHERMAN WAY	91405	2	183B157    75	2328008074	(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.20102	-118.4293	Install a roof-mounted solar array on a 5-story 65 unit apartment building.System size: 14kW. Ungrounded system. (70) 275W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18473	12041-10000-11768	432 E 103RD ST	90003	8	091-5A207 315	6063013009	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	06/07/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	33.94274	-118.26615	Plan check for roof mounted 3.22KW Enphase Mircoinverter M215 system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18474	10041-10001-06937	5376 E HUNTINGTON DR SOUTH	90032	14	144A237    50	5219033001	C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.09057	-118.16424	((CHANGES MADE TO PREVIOUS APPROVED SET. ADDED 1 NEW PANEL AND NEW LOADS. HAZARDOUS AREA.)))NEW GAS STATION. PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18475	16041-20000-08315	9043 N WOODMAN AVE	91402	6	195B153   158	2639033013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.23393	-118.43976	Plan check for power and energy. Project site is a single unit within an existing commercial building. Project scope is a change of use from retail to a medical office and a tenant improvement. Work is being done within exam rooms. Total lighting area = 2,500 sq. ft.Note: Building permit has been pulled under 15016-20000-27594	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18476	19041-10001-00436	6326 W LINDENHURST AVE	90048	5	135B177   331	5510020029	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM			PC Approved	05/17/2019 12:00:00 AM	ADDRESS	34.06612	-118.36579	PLAN CHECK FOR UPDATE SET OF PLANS - CHANGES ARE CLOUDED UNDER DELTA 2 (RELOCATION OF MAIN PANEL)CHANGES TO APPROVED SET INSTALLATION OF 1 ENERGY STORAGE SYSTEM TO PV PERMITTED. SCOPE INCLUDES: ONE LG CHEM RESU10H 9.8KWH BATTRY. SOLAREDGE AUTO TRANSFORMER, AND ONE PANEL.PV FEES WERE PAID UNDER THE ONLINE PERMIT NUMBER 18041-90000-29872ORIGINAL PV PERMIT 18041-90000-29851	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18477	12041-20000-05962	9535 N RESEDA BLVD	91324	12	198B125    33	2763036009	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Closed	02/04/2015 12:00:00 AM	ADDRESS	34.24326	-118.53635	T.I. to existing space of the Dental office.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18478	19041-10001-16882	5057 N MATILIJA AVE	91423	4	171B153   661	2269004023	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM			PC Approved	11/01/2019 12:00:00 AM	ADDRESS	34.1629	-118.4336	PLAN CHECK FOR A LOST OF SET OF DRAWING. PLAN CHECK TO MATCH FIELD INSTALLED EQUIPMENT. _________________________________________PC FOR PV1, SYSTEM SIZE IS 8.640KW. SYSTEM INCLUDES 27 LONGI SOLAR MODULES W P320 SOLAREDGE OPTIMIZERS AND 7600 SOLAREDGE INVERTER, adding on to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18479	19041-20003-00997	20851-20853 N SHERMAN WAY	91306	3	183B109    62	2113013038	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM			PC Approved	08/07/2019 12:00:00 AM	PIN	34.20136408	-118.5880133	Revisions to approved plans.  Approval for clouded and initialed changes only.  Change to panelboard details/series ratings. (((Fire-damaged building and tenant improvements. Plan check for power and energy. Total area: 5250 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18480	12041-20000-08851	250 S ALEXANDRIA AVE	90004	13, 4	168B153   454	2269025***	R3-1	Central, South Valley	Wilshire	Wilshire Center - Koreatown		1287.02, 2113.10	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.06971	-118.2977	"TI for a small restaurant. Plan check for energy and emergency lighting. 410 conditioned sqft. Low rise commercial. NOTE TO INSPECTOR: TENANT IS LOCATED at 250 A Fashion Square inside Westfield Sherman Oaks. Tenant is ""Massis Kabob"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18481	12041-10001-06187	1659 S SHENANDOAH ST	90035	5	129B169   966	4303009015	R2-1-O	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2012 12:00:00 AM	06/11/2012 12:00:00 AM		Permit Finaled	06/20/2012 12:00:00 AM	ADDRESS	34.04844	-118.38258	PLAN CHECK NEW ROOF MOUNTED  5.13 KW PHOTOVOLTAIC SYSTEM. SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18482	18041-10000-31617	737 W PACIFIC COAST HWY	90710	15	036B197   986	7413033040	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.79118	-118.28867	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18483	13041-10000-19803	101 N LARCHMONT BLVD	90004	4	138B189   974	5515019012	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.07317	-118.32382	TENANT IMPROVEMENT. TITLE 24 PLAN CHECK ONLY. INSTALLING NEW LIGHT FIXTURES AND MOVING EXISTING LIGHT FIXTURES.  912 SQFT. PERMIT TO BE PULLED AT ELECTICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18484	13041-20000-07409	777 S FIGUEROA ST 1500	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			PC Approved	03/21/2013 12:00:00 AM	ADDRESS	34.04828	-118.26116	Change to lighting in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18485	15041-10001-19822	101 W 5TH ST	90013	14	129A211   281	5149022***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Closed	10/21/2016 12:00:00 AM	ADDRESS	34.0469	-118.24862	Change to approved set by updating the existing service size from 400-Amp to 1200-Amp 277/480V 3-phase 4-wire, change also apply to  panel A and B from singple phase to 3 phase panel(((TI TO AN (E) BUILDING. CHANGE OF USE TO A RESTAURANT LOCATED ON THE GROUND LEVEL 4000AMP SERVICE. FULL PC FOR ENERGY AND POWER. TOTAL SQ. FT. 1800.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18486	15041-10000-37655	700 S FLOWER ST #520	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI, T-24 TO AN OFFICE SPACE IN THE 5TH FLOOR OF AN  (E) HIGH RISE BUILDING, THE BLOC.  EXISTING PANELS, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ.FT. 2989.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18487	10041-20000-09117	6253 W HOLLYWOOD BLVD #203	90028	13	148-5A189 343	5546030035	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	ADDRESS	34.10179	-118.32624	Plan check T-24 Energy for existing office space #203	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18488	12041-10000-15090	615 E 61ST ST	90001	9	105B205   522	6007006024	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			Reviewed by Supervisor	08/29/2012 12:00:00 AM	ADDRESS	33.98449	-118.26437	Plan check for new 25.657KW roof mounted photovoltaic system for an existing commercial building with multiple services. Photovoltaic system will be installed for each services under seperate application. (3 of 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18489	17041-10000-31419	1450 S BARRINGTON AVE	90025	11	126B149    89	4263020011	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			09/19/2017 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	05/03/2021 12:00:00 AM	ADDRESS	34.04504	-118.45689	Full plan check for a new 4 story 20 unit, Type VA, apartment building over one level, basement garage. 5 typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18490	13041-10000-32170	12875 W RUNWAY ROAD UNITS 1-6-BDLG 4	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/26/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	33.97528	-118.42029	INSTALLATION OF A NEW FIRE ALARM SYSTEM for a 4 story residential building (Building 4). THIS IS BUILDING 4 OF 6.  THE FACP IS ON BUILDING # 2. There are two building types for the site. Building 4 plan is type 6 ( SIGNIFYING 6 PLEX ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18491	13041-10000-30300	14618 W SYLVAN ST	91411	6	178-5A151 140	2241011005	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			10/29/2013 12:00:00 AM			PC Info Complete	11/27/2013 12:00:00 AM	ADDRESS	34.18442	-118.45151	FIRE ALARM FOR NEW 4-STORY 10 UNIT APT BLDG PLUS ROOF, WITH 1ST-FLOOR PARKING GARAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18492	13041-10000-12338	1733 N WESTERN AVE	90028	13	148-5A193  65	5544005014	[Q]C4-2D	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			05/13/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	PIN	34.10274688	-118.30967876	permit to be pulled at EPC counter only.PC FOR ENERGY ONLY. <400A PER APPLICANT. LIGHTING FOR EXIST PKG LOT. panel and 2 h.i.d. pole-mounted luminaires	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18493	19041-10000-02509	1800 S ROXBURY DR	90035	5	129B165   674	4307013019	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.04854	-118.40112	New rooftop solar system on (E) SFD, (42) modules SOLARIA POWERXT-360 with power optimizer P400, (1) inverter SE 11.4 kW AC. Total system power is 11.4KWAC/15.120 KWDC. System interconnect to 225A rated bus. Inspection fees are $0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18494	12041-20000-13773	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I. to existing space 250A inside the mall.  Install general/emergency lights. Plan check for energy only.Note: Permit issued under 12041-20000-13775	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18495	19041-20000-14936	10115 S GRAPE ST	90002	15	091-5A215 106	6046022019	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	06/23/2020 12:00:00 AM		Permit Finaled	07/31/2023 12:00:00 AM	ADDRESS	33.94446	-118.23688	PLAN CHECK FOR NEW 3-STORY CHARTER SCHOOL. SERVICE SIZE 800A 480/277 3P 4W. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 64,164 SF. SCOPE OF WORK INCLUDES (2) 800A PANELS, (1) 1000A PANEL, (17) 200A PANELS, A 30HP ELEVATOR, A 300KVA TRANSFORMER, (4) EV CHARGERS TWO OF WHICH TO BE FUTUREB#19010-10000-01460	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18496	10041-20000-25674	2030 S CENTRAL AVE	90011	9	120A211   262	5119001004	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Southeast / Central Avenue		2270.10	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Expired	02/06/2013 12:00:00 AM	ADDRESS	34.02299	-118.25164	PLAN CHECK POWER AND ENERGY FOR NEW RETAIL (FIRST TIME TENANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18497	17041-10000-42134	1671 W BEVERLY BLVD	90026	13	135A207   171	5159012034	C2-1	Central	Westlake	Greater Echo Park Elysian		2083.02	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.0645	-118.2651	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18498	19041-20001-17500	14609 W DEL PLAYA ST LOT 4-pv1	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM			PC Approved	07/05/2019 12:00:00 AM	ADDRESS	34.24792	-118.45074	07/05/2019 Changes to an approved set of plans. AC PV module model has changed. Changes have been reflected throughout plan set. Changes have been clouded and marked as Delta 1.*****Original Work Description*****pv1install roof mounted pv system sized 3.02KW AC interconnected with msp.(9) acm rated 335W each	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18499	14041-10000-30873	6801 W HOLLYWOOD BLVD A3-322-Ste 316	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	inthe  food court ,installing luminaires and ckts in existing take-out restaurantplan chk is for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18500	14041-20000-18704	4268 S HOBART BLVD	90062	8	114B193  1292	5021023025	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.00542	-118.30764	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.1KW INTERCONNECTED WITH MSP.(19) SOLAR WORLD SW-250(19) ENPHASE MICROINVERTERS M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18501	13041-20000-32340	172 N LA BREA AVE	90036	5	138B181   486	5513003003	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.07563	-118.34384	Change to lighting only in an existing retail space.  Load is less than 400 amps per the applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18502	11041-10000-10860	2941 W 70TH ST	90043	8	102B189   584	4008011058	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01, 2352.02	Electrical	Electrical	Public Safety Only			05/26/2011 12:00:00 AM	06/07/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.97648	-118.3254	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18503	12041-20000-18824	14006 W RIVERSIDE DR #265	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24 lighting plan check for remodeled TENANT IMPROVEMENT OF (E) RETAIL STORE. ALL WORK PER ARCHITECTS DESIGN.(SEE COMMENTS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18504	14041-20000-10254	5767 N VAN NUYS BLVD	91411	4	174B149   355	2244028008	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	PIN	34.17542154	-118.44919444	Use of land for parking lot automobile sales.  Title 24 plan check for lot lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18505	17041-10000-39737	1340 S FIGUEROA ST GND FL	90015	14	126A205    58	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Issued	12/11/2017 12:00:00 AM	ADDRESS	34.03951	-118.26852	NEW 600A DISTRIBUTION BOARD TO SUPPLY FUTURE RETAIL TENANT PANELBOARDS. NO CIRCUITS ADDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18506	18041-20000-25194	11379 N REY TERRACE WAY	91342	7	213B177   289	2529012040	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.27656	-118.36125	Plan check for PV roof mounted system, system size: 12.8kW with 43 modules and 2 inverters(7.6kW and 5.2kW) connected to 225A with main breaker 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18507	14041-10000-02549	8614 N AMESTOY AVE	91325	12	195B133   513	2690019006	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.22694	-118.50684	PV1 6KWdc. 240V. negative GND. NONstd. 1story. Roofmount. [(1) inverters: {Fronius IG PLUS V 5.0-1UNI}]. [(24)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18508	13041-20000-19387	920 W DOWNEY WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.02063	-118.28879	NEW FIRE ALARM SYSTEM FOR USC. BIEGLER HALL OF ENGINEERING. EXISTING SCHOOL. 89 DEVICES, NEW PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18509	19041-20001-23269	20867 W LASSEN ST	91311	12	201B109    90	2741002005	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM			PC Approved	12/13/2019 12:00:00 AM	ADDRESS	34.25013	-118.58821	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGE ONLY, CHANGE TO T24 SHEET, CHANGE TO REQUIRED DOCUMENT INDICATORS AND MANDATORY DEMAND RESPONSE CONTROL AND INDICATION OF NO SKYLIGHT/DAYLIGHT SENSORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18510	14041-10000-34704	2047 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.03973	-118.44287	982 sq. ft. (E) restaurant TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18511	10041-10000-00904	13450 W MAXELLA AVE	90292	11	105B153    47	4212004019	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	01/09/2012 12:00:00 AM	ADDRESS	33.98645	-118.44148	Intalling outdoor lighting around shopping mall of building courtyard, cottage A and coutage B. This plan check is for title 24 for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18512	15041-10000-05322	2828 S NAOMI AVE	90011	9	117A211   203	5119017014	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.01504	-118.254	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 7280 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18513	18041-20000-12678	7349 W 91ST ST	90045	11	093B157    38	4119017011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	33.95445	-118.42434	Plan check for battery back up system Tesla Powerwall 2.0 install to existing PV	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18514	13041-20001-03123	6501 N FALLBROOK AVE	91307	3	180B097   471	2038040016	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.1881	-118.62368	PLAN CHECK FOR POWER AND ENERGY. ELECTRICAL WORK IS FOR NEW OLIVE GARDEN RESTAURANT. ((changes to approved set of plans. new circuit for TO - GO fridge, and rearrangment of some lighitng. pc and permit for this application, changes clouded dealta 10))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18515	18041-20000-42691	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	ti to an existing commercial building.  adding new lighting new controls to new equipment.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18516	15041-20000-08937	5657 W CENTURY BLVD	90045	11	090B169    20	4125025040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	33.94571	-118.38094	Plan check for Title 24 only. Project scope is a tenant improvement to the office within a below-ground parking structure. Total lighting area = 1,540 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18517	18041-10000-44387	2412 W 48TH ST	90043	8	111B189   930	5015038001	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM			Reviewed by Supervisor	12/03/2018 12:00:00 AM	ADDRESS	33.99991	-118.31984	PC FOR POWER ONLY. SCOPE INCLUDES INSALLING A NEW 600A 120/240V SINGLE PHASE SERVICE/DISTRIBUTION BOARD, AND REPLACING SIX 100A NEW PANELBOARDS.  REFEEDING EXISTING CIRCUITS TO NEW PANELBOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18518	16041-20000-14235	14620 W PARTHENIA ST	91402	6	192B149     9	2638039020	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	04/02/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.22724	-118.45079	Plan check for energy only. TI to supermarket's meat and fish service department. New ligthing (incl. emergency). 3,142sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18519	15041-30000-39682	10960 W WILSHIRE BLVD Ste 1925,-1950, 1955	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	Title 24 plan check only.  Total area = 9,830 sq. ft.   T.I. to commercial highrise office space.  One new subpanel (new load < 400 A).  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18520	12041-10000-02347	9600 S SEPULVEDA BLVD	90045	11	093B165   137	4124025049	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	33.94841	-118.39594	remodel parking ticket office-plan chk is for title 24PERMIT FEE IS IN THE INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18521	17041-20001-43590	4950 N ALONZO AVE	91316	5	168B129    74	2182003020	RE9-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.16037	-118.5205	Changes to approved set - online permit.  Reduction of system size to (16) modules with (1) 5kW rated string inverter.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18522	17041-20001-32817	9527 N LANGDON AVE	91343	7	201B145   622	2656012003	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM			PC Approved	10/05/2017 12:00:00 AM	ADDRESS	34.24384	-118.46991	Expedited plan review fee. PV1.  Install  17.4 kW DC roof mounted grid tied PV system.  (60) modules with Enphase M250 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18523	19041-20000-41066	11881 W TERRA VISTA WAY #120	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18524	10041-20003-14353	1680 N VINE ST	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Expired	10/09/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	Delta 4 revision plan check for installing existing FB switchboard to new main 4000A MS switchboard. FB switchboard shall be disconnected and removeed. MS and HP1 panel to supply existing elevator, equipment and BB subpanel. Revise MS service load calculations. Permit includes new transformer and intercepting existing feeders to new MS and HP1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18525	14041-10000-22004	9156 N CEDROS AVE	91402	6	198B149   456	2651008017	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.23714	-118.45341	PV1. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.65 KW DC.(30) KYOCERA 255 MODULES (1) POWER ONE 6000 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18526	17041-20002-09071	12700 W VAN NUYS BLVD bldg 5,6	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	Revision to approved set.  Delta-4 revisions only.  Load side tap connection detail change.  (((PV2.  Install roof mounted PV system sized 9.8kW to be interconnected with subpanel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18527	14041-10001-30506	19500-19600 S VERMONT AVE	90502	15	057B197    21	7351033009	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.85326	-118.29031	(((6/23/2015- CHANGES MADE TO APPROVED SET. ADDING NEW CIRCUITS AND EXPANDING LUNCH ROOM. RELOCATING IT ROOM. T24 TO BE RE-VERIFIED)))Tenant improvement serving warehouse/office building.  Plan check for power and energy - more than 400A of connected load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18528	12041-10000-02254	12801 N MEADOWLARK AVE	91344	12	222B133   490	2602014016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2012 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.30305	-118.50881	New roof mounted 8.46 kw solar system for a single family. EPC for power. (Zoning variance was filed)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18529	12041-20000-01653	6550 N PEACH AVE	91406	6	180B145   422	2234017025	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2012 12:00:00 AM	02/15/2012 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.19012	-118.46741	New root mounted 6.5KW P.V. system with more than 2 strings of one of the inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18530	16041-20000-17387	330 S BERENDO ST	90020	10	135B197   395	5502007018	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.06809	-118.29397	"""0$ permit fees due to senate bill 1222""PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 48KW INTERCONNECTED WITH MSP."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18531	15041-10000-01266	7868 N DEERING AVE	91304	3	189B105   397	2109017036	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.21282	-118.59394	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 10268 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18532	16041-10000-30320	1501 N SOTO ST	90033	14	133-5A227   7	5202002022	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.06079	-118.19919	PC FOR ENERGY. OUTDOOR SIGN  LIGHTING  (EXTERNALLY ILLUMINATED) INCLUDE 70 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18533	16041-10000-27669	333 S SPRING ST # C	90013	14	130-5A211 168	5149019035	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.04956	-118.24793	FULL PC FOR POWER AND ENERGY. TI AND CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES FOUR NEW SUBPANELS, LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 1845 SQ. FT.((B# 16016-10000-09636))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18534	12041-20000-17082	851 W DOWNEY WAY 2nd floor	90089	9	118-5A201  14	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM			PC Approved	07/23/2012 12:00:00 AM	ADDRESS	34.02004	-118.28659	T-24 and emergency lighting plan check for second floor remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18535	14041-20001-33802	10948 N HILLHAVEN AVE	91042	7	210B197   416	2553018013	RE9-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	12/17/2014 12:00:00 AM	ADDRESS	34.26839	-118.28803	Fee for expedite only.*****Previous description*****Roof mounted PV system with total system size 7.2KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18536	17041-20000-41267	16661 W VENTURA BLVD	91436	5	168B137   270	2259011034	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.15837	-118.49645	Common area lighting in commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18537	15041-10001-20264	12905 W LANDALE ST	91604	2	165B161    71	2362006013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			08/30/2016 12:00:00 AM			PC Approved	02/03/2017 12:00:00 AM	ADDRESS	34.15231	-118.414	08/30/16Changes in design from 9 units to 10 units apartment building. Original application and permit number is 15041-10000-20264	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18538	15041-10000-21220	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake			2088.01	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM			PC Info Complete	07/06/2015 12:00:00 AM	ADDRESS	34.06281	-118.2731	Plan check for power only. Main scope for the project is swaping out a temp 125-KVA generator  with an optional  375-KVA generator permanently . All feeders for the scope are also updated with a proper size. per F.Y over the counter. Reference application #: 15041-10000-17615	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18539	19041-10000-27515	2901 E OLYMPIC BLVD	90023	14	120A223   115	5170023001	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.02251	-118.21532	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18540	15041-20000-25056	18124 W CHARDON CIR	91316	5	165B125   165	2184031030	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.15004	-118.52891	Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (4) inverters, (90) modules, and (1) load center.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18541	15041-20000-22570	15201 FRED WAY	91405	6	186B145  1128			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	PIN	34.2092387	-118.46409749	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18542	17041-30000-18981	2409 N GRIFFITH PARK BLVD	90039	4	148-5A205  38	5432003004	RD2-1VL, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Apartment			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.10303	-118.27254	Plan check for Fire alarm system 13 units appartment 3 story. Total Fire alarm devices: 71 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18543	15041-10000-25787	8100 N WOODLEY AVE	91406	6	189B141    22	2206005012	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.21787	-118.48348	NEW MOTORS FOR PROCESS EQUIPMENT AT INDUSTRIAL FACILITY.  PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18544	19041-20000-08739	6601 S CENTER DR WEST 4th flr	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Issued	03/12/2019 12:00:00 AM	ADDRESS	33.97997	-118.39375	ti to an existing cpommercial building (high rise).   adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18545	10041-10000-06824	5070 W WILSHIRE BLVD	90036	4	132B181    40	5507027024	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	34.0619	-118.3402	parking outdoor lighting , light poles and night lights. oltg	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18546	16041-10001-19099	1611 S WESTERN AVE	90006	10	126B193   319	5073012031	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM			PC Info Complete	07/25/2017 12:00:00 AM	ADDRESS	34.04297	-118.30926	Changes to approved set.  Change from two prefabricated cook counter panels to two 100 amp subpanels with associated cooking equipment loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18547	18041-10000-49012	4020 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   525	5032007002	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.01553	-118.34328	CHANGE OF USE FROM GROCERY STORE TO RESTAURANT/MARKET. T-24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18548	17041-10000-07357	8646 N HATILLO AVE	91306	3	192B113    11	2782018001	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.22687	-118.56451	PV INSTALL NEW 5.760 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(18) MODULES: CANADIAN SOLAR CS6X-320P(1) SOLAR EDGE SE5000A-US WITH OPTIMIZER	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18549	13041-20000-32287	9975 N STANWIN AVE PV1	91331	6	204B153   912	2645014020	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.25203	-118.43841	New 8.8kw rooftop PV system.  System is UNGROUNDED. sfr	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18550	17041-10001-19787	418 N NORTON AVE 1-35	90004	4	141B189  1146	5522022008	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.07908	-118.3169	PC FOR CHANGES TO APPROVED SET, ALL CHANGES ARE UNDER DELTA 3. SCOPE OF WORK INCLUDES REVESION TO SINGLE LINE, AND REVESIONS TO DWELLING UNIT FLOOR PLANS. PERMIT HAS BEEN ALREADY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18551	04041-10002-31759	1925 W WILSHIRE BLVD	90057	1	132A203    23	5142001022	C4-2	Central	Westlake		YES	2089.02	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Expired	07/30/2012 12:00:00 AM	ADDRESS	34.0574	-118.27431	1-20-10 - Supplemental is for changes to previously approved plans.  New plans have new panel addition and lighting configuration.  Loads on panel(s) and service have been updated to reflect as built.  P/C is for Power and Energy. :: RENOVATION FOR THE LA OPEN DOOR PRESBYTERIAN  CHURCHVARIANCE IS FILED TO SEPARATE THE FA PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18552	15041-20000-36584	241 S FIGUEROA ST Suite 240	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM			PC Approved	10/30/2015 12:00:00 AM	ADDRESS	34.05598	-118.25392	Plan check for Title 24 only. Project site is a tenant space within an existing commerial building. Project scope is a tenant improvement. Total lighting area = 1,192 sq. ft.Note: Building permit has been filed under 15016-10000-20414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18553	10041-20000-24911	408 S GLESS ST	90033	14	127-5A219 328	5171001907	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Public Safety Only			12/14/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.04265	-118.22256	Plan check for new fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18554	13041-20000-06046	9940 W SHADOW HILLS DR	91040	2	204B181   137	2543013049	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.2585	-118.3479	SOLAR SINGLE FAMILY 13.9 KW 2 INVERTERS 7 KW AND 5 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18555	19041-10001-46681	130 S SOTO ST 1-5	90033	14	127-5A223 273	5180003030	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Apartment			11/13/2019 12:00:00 AM			PC Approved	12/27/2019 12:00:00 AM	ADDRESS	34.04277	-118.21018	Expediante FEES***********PC for PV system for (commercial building), 30 PV modules HANWA, with microinverters and 2 load centers.***********	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18556	14041-20001-14146	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM			PC Approved	09/04/2014 12:00:00 AM	ADDRESS	34.0352	-118.45736	CHANGES MADE TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 5. LITTLE CHANGE TO POWER PLANS. THIS APPLICATION IS FOR RECHECK FOR CHANGES TO T24. PLAN CHECCK ONLY APPLICATION FOR DELTA 5 REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18557	17041-20000-45585	1126 1/2 N LEMOYNE ST	90026	13	139-5A209 214	5404017008	R3-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Apartment			12/19/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.07635	-118.25991	PV2.  Install 3.54 kW roof mounted grid tied PV system.  (12) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18558	19041-10000-35389	660 S FIGUEROA ST STE 1888	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	ENERGY PC FOR TENANT IMPROVEMENT TO (E) OFFICE. AREA OF SCOPE 3,365SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18559	17041-20000-12642	333 S GRAND AVE 38th flr	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	ti to an existing commercial high rise building (bathrrom).  adding new lighitng new controls to existing panels.  plan check for energy only.  scope to be performed in the 38th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18560	18041-10000-09581	11611 W CANTARA ST	91605	6	192B169   514	2311001012	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.2194	-118.38509	REMOVE INDOOR-OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18561	10041-20000-14927	10940 W VICTORY BLVD	91606	2	180B173   884	2414001002	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	08/26/2010 12:00:00 AM	ADDRESS	34.18652	-118.36952	Plan check T-24 Energy for lighting in office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18562	16041-20000-33541	800 S FIGUEROA ST STE 600	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Issued	11/17/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,113 sq. ft. Note: Building permit has been pulled under 16016-10000-22169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18563	19041-10000-30809	6840 N TROOST AVE	91605	2	183B169   415	2320009006	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Issued	08/07/2019 12:00:00 AM	ADDRESS	34.19538	-118.38628	PC for new fire alarm system in a storage area, scope of work includes a new fire alarm panel, 2 batteries, and 78 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18564	13041-20000-14496	11914 N NUGENT DR	91344	12	216B129   292	2601051029	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.28708	-118.51613	New rooftop mounted PV System for an existing sfr.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18565	16041-20000-26769	345 S NEW HAMPSHIRE AVE 1-66	90020	10	135B197   394	5502007009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.21	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.06775	-118.29309	Plan check for PV roof mounted system. System size: 40kW with 176 modules and 4 inverters(10.0kW) connected to MSP.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18566	14041-10000-09134	9030 N OWENSMOUTH AVE	91304	3	195B105    34	2779018012	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.23452	-118.60151	New service of 800 amps, 3 ph. 4 wires- wharehouse, connecting existing circuitury to new panels.  Lighting, receptacle and receptacles are existing to remain.  adding one circuit for emergency	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18567	14041-10007-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.0504	-118.26023	"Delta 7 revisions: new circuits egress lighting;added drawings to show some floors layouts; new circuits for housekeeping roomsupdate lighting on some floors;new TCP panels; new circuits for elevator smoke curtains and dampersAttached to the plans is the list of changes (((((((PLANCHECK FOR POWER AND ENERGY. HIGH RISE CORE AND SHELL BUILDING INCLUDING 5 LEVEL PARKING GARAGE. "" WILSHIRE GRAND "" PROJECT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18568	19041-10000-46425	5500 W OLYMPIC BLVD	90036	4	132B181   683	5085010001	R3-1-O-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	09/23/2022 12:00:00 AM	ADDRESS	34.05705	-118.34935	NEW FIRE ALARM SYSTEM WITH 26 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18569	12041-10001-31078	18211 W VENTURA BLVD	91356	3	171B125   273	2160014010	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.16621	-118.52912	Plan check for energy and emergency lighting. Stand alone building. Office Depot. 7460 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18570	12041-10000-22053	11444 W OLYMPIC BLVD	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/17/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Expired	10/14/2014 12:00:00 AM	ADDRESS	34.03654	-118.44363	PLAN CHECK T24 ENERGY/EMERGENCY LIGHT RESTROOM, ELEVATOR WAITING AREA, AND CORRIDOR LIGHTING ON THE 6TH FLOOR OF HIGH RISE BUILDING. PERMIT FOR NEW NORMAL AND EMERGENCY LIGHTING BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18571	14041-10000-04643	608 W OLIVER ST	90731	15	018B197   316	7448010038	R2-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	33.74704	-118.29034	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. 3 KW DC.(13) TRINA TSM-235(13) ENPHASE M215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18572	16041-20000-42372	403 W ADAMS BLVD 2nd Floor	90007	9	121-5A205 317	5126017018	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.02746	-118.27394	Plan check for power only. New feeder for xray equipment in health clinic.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18573	16041-20001-40144	11285 W GOSS ST	91352	6	192B173   329	2632006007	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.22321	-118.37713	Expedited per applicant request.Plan check for installation of roof-mounted solar PV system on commercial building.30kW (10+10+10) ungrounded system. (89) 315W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18574	17041-10000-07170	2300 W BEVERLY BLVD	90057	13	136-5A205 272	5154010034	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Apartment			03/06/2017 12:00:00 AM	03/06/2017 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.06761	-118.27314	Plan check for new fire alarm system on new building 45 units appartment. Total fire alarm devices: 115 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18575	13041-10000-34767	3201 N LACY ST	90031	1	142-5A221 272	5205002902	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM			PC Info Complete	08/01/2014 12:00:00 AM	ADDRESS	34.08349	-118.21854	[[[[[[[[[[[[[[[[[[[[[[[PLEASE INFORM KUMAR OR NABIL. TEMPORARY POWER PLAN CHECK ASSOCIATED WITH THIS IS ON HOLD TO BE RELEASED UPON SUBMITTAL OF THIS PLAN, PC # 13041-10000-34763]]]]]]]]]]]]]]]]]]PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT WITH NEW 1200 AMP SERVICE. 1 STORY. 150KW EMERGENCY GENERATOR  ANIMAL SHELTER.building permit # 13014-10000-04943 RENOVATION/REMODEL OF (E) ANIMAL CARE FACILITY  ABOUT 5000 SQ ADDITION; NEW PARKING DESIGN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18576	10041-20000-25650	11030 W SANTA MONICA BLVD	90025	5	129B153   788	4323019051	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.04796	-118.44228	New roof mounted 19.35 KW P.V. system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18577	15041-20000-32004	6203 N LANKERSHIM BLVD	91606	2	177B169   328	2335032022	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.1834	-118.38599	Title 24 plan check only.  Total area = 1,625 sq. ft.    T.I. to existing retail building.  New lighting and receptacles.permit pulled under this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18578	19041-20000-25890	17864 W VENTURA BLVD	91316	5	171B129   288	2182002012	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.16335	-118.52213	PLAN CHECK FOR POWER AND ENERGY FOR A TI TO EXSITNG COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW 1000A MAIN DISTRIBUTION PANELS AND (2) NEW SUBPANELS WITH LOADS CONNECTED TO AN EXISTING SERVICE. T24 IS ALSO INCLUDED, TOTAL SQUARE FOOTAGE = 5000 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18579	16041-10000-18049	1819 S KELTON AVE 1-26	90025	5	129B153   712	4323007035	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			05/23/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.04845	-118.43869	PC FOR POWER AND ENERGY. PROPOSED 4-STORY APARTMENT WITH BASEMENT GARAGE.  SEE 15020-10000-01932 FOR TEMP. SHORING AND 15030-10000-04926 FOR GRADING WORK. TOTAL AREA  14386 SQ FT. FIRE ALARM TO BE FILED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18580	16041-10000-31243	16769 W BOLLINGER DR	90272	11	129B121  1005	4415008022	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.04556	-118.54523	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18581	15041-10000-17786	11675 N GLENOAKS BLVD	91331	7	213B157   218	2524022003	C2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.2823	-118.42116	(9-24-15  this is plan check only for expierd plan check.    ins pection  permit to be pulled under original permit #   12041-10000-00249   m.z(((6/9/2015))))RESUBMITTAL OF APPROVED SET OF PLANS.  PC TIME EXPIRED.  TWO VARIANCES WERE SIGNED AND NEVER PAID BY APPLICANT.  FEES CHARGED HOURLY.  REFER TO APPLICATION NUMBER 12041-10000-00249 FOR EQUIPMENT FEES.  Convert an existing supermarket into a church.  New 600A service, new panels, circuits, and lighting.  Full plan check.  <<<Applicant has a pre-cut check, additional fees may be necessary>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18582	17041-10000-21158	10250 W SANTA MONICA BLVD STE. 2300	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for 1st time tenant ""TOCAYA"" Restaurant located in Westfield Century City Ste#2300. Total area: 2,880 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18583	18041-10000-06910	19817 W RINALDI ST	91326	12	213B113   308	2701040043	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	PIN	34.2768008	-118.56487771	Full plan check for Tenant Improvement of an existing commercial retail building. Reusing multiple existing panels with new circuits and new additonal load > 400A, install (1) new panel, new lighting and new receptacle. Total area: 43,160 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18584	14041-10000-27676	9813 N WOODALE AVE	91331	6	201B153   336	2645024030	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Expired	10/31/2016 12:00:00 AM	ADDRESS	34.24892	-118.43694	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD CENTRAL INVERTER PLAN. SYSTEM SIZE: 6.63 KW(27) KYOCERA KD 255(1) ABB # PVI 6.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18585	17041-20000-34499	16501 W ALYSE CT	91436	5	168B137   808	2284005037	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Expired	04/27/2024 12:00:00 AM	PIN	34.1561989	-118.49263244	Plan check for AC coupled battery backup system for SFD.(4) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18586	12041-10000-01011	2401 E 1ST ST	90033	14	127-5A223 160	5180002017	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			Corrections Issued	01/17/2012 12:00:00 AM	ADDRESS	34.04371	-118.20942	Change of lighting to a check cashing store.   PLAN CHECK ONLY for Energy, No Emergency lighting per applicant.  Permit has already been pulled on application 11041-10000-10576  No suite number	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18587	18041-20000-10516	10753 N TUJUNGA CANYON BLVD	91042	7	207B197   572	2557010002	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.26459	-118.29527	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter, (10) modules, (1) load center, and (1) Tesla PowerWall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18588	14041-20000-16562	4322 N CEZANNE AVE	91364	3	165B101   333	2173003004	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.14631	-118.60427	PV1Install roof mounted solar array on SFD. System size: 6kWCentral Transformerless Standard Plan.(25) REC SOLAR REC260PE pv modules(1) PowerOne PVI-6000-OUTD-US-A transformerless inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18589	18041-10000-47284	5401 N OSTROM AVE	91316	5	174B133   811	2258004004	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.16945	-118.50704	permit fee $0.00 by state senate bill no. 1222NEW ROOFTOP 15.2 KW AC PV SYSTEM FOR (E) SFD, SCOPE INCLUDES (60) PANASONIC PV MODULES WITH OPTIMIZERS, AND (2) 7.6 KW AC SOLAREDGE SE7600H-US INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18590	15041-20001-28568	3498 N ALANA DR	91403	5	159B141    45	2280017043	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.13547	-118.47963	Expedited per customer request.PV1. Install roof mounted PV system sized 15.4 kW. Interconnected with main service panel.(56) Kyocera KD 265 Modules(2) SMA SB7700 TL Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18591	17041-10001-44994	5200 N LANKERSHIM BLVD #410	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC FOR CHANGES TO APPROVED SET.  ALL CHANGES MARKED UNDER DELTA 1. SCOPE INCLUDES CHANGES TO FIXTURE AT THE ENTRANCE AND REVISED T-24 FORMS. THIS IS PLAN CHECK ONLY!PERMIT PAID UNDER MASTER. Design build. Energy plan check for an office T.I. Scope includes new light and equipment. Total area is 1,498 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18592	16041-10000-09988	2000 N RONDA DR	90032	14	135A231    46	5215025007	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.06563	-118.18434	PV1  4.67 KW roof mounted system with (17)M215  micro inverters and Qantum Solar modules (G3-275) interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18593	16041-20000-15064	5933 N FULTON AVE	91401	2	177B157   937	2343025013	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.17863	-118.42268	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.41 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18594	13041-20000-17318	17308 W VENTURA BLVD	91316	5	168B133    18	2290001002	QC4-1VL, QP-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.16075	-118.5104	Plan check for energy and emergency lighting. Starbucks	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18595	14041-10000-04239	520 S VIRGIL AVE #505	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.06457	-118.28687	Ti in an existing medical office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18596	15041-10000-11131	210 S OCEAN FRONT WALK	90291	11	109-5A141 164	4286030903	OS-1XL-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM			PC Info Complete	08/30/2019 12:00:00 AM	ADDRESS	33.99485	-118.48086	Energy plan check for in/outdoor area ; scope includes installing new lighting for public restroom and outdoor area. Total area is 4145-SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18597	18041-10000-40544	4049 N VERDUGO ROAD	90065	14	157-5A217 340	5459015004	[Q]C1.5-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.12433	-118.23179	NEW ROOF MOUNTED SOLAR SYSTEM USING (20)AC MODULES INTERCONNECTED IN A SOLAR ONLY PANEL. TOTAL SYSTEM SIZE IS  7.2KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18598	19041-10000-32071	581 N WILCOX AVE	90004	4	141B185   879	5523037034	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.08121	-118.33105	(ePlan)] PLAN CHECK FOR ROOF MOUTED 3.8KVA/4.095CECAC SYSTEEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) WITH 13 MODULES USING P400 OPTIMIZERS AND ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18599	15041-10000-35094	849 W 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	PIN	34.02383917	-118.28572873	NEW FIRE WARNING SYSTEM FOR  GLORYA  Dance Center building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18600	18041-10000-41219	1037 W VICTORIA AVE	90291	11	111B149    12	4242003007	R1V2	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	PIN	33.99620455	-118.45456632	plan check for roof mounted pv system for 8.26KVA system consisting of 28 LG modules using IQ7-72-2-US PLUS micro inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18601	10041-10000-21974	9071 1/2 N WOODMAN AVE	91402	6	195B153    73	2639032013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM			PC Info Complete	11/03/2010 12:00:00 AM	PIN	34.23444128	-118.44065672	TI IN AN EXISTING RESTAURANT. PLAN CHECK IS FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18602	13041-10000-13095	624 S LA BREA AVE	90036	4	135B181   685	5507023023	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.06413	-118.34382	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT EXISTING BAKERY TO BAKERY/RESTAURANT. SCOPE OF WORK > 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18603	15041-10000-17825	8803 W MULBERRY DR	91040	7	207B189   475	2547028033	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Expired	07/04/2017 12:00:00 AM	ADDRESS	34.26476	-118.32428	INSTALL NEW 7.8 KW DC  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (30) MODULES: KYOCERA KU2606XPA(1) INVERTER: PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18604	19041-10000-52736	2021 W TEMPLE ST 1-40	90026	13	136-5A207  17	5157023011	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		2084.02	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM			PC Info Complete	09/03/2020 12:00:00 AM	ADDRESS	34.07018	-118.26717	FULL PLAN CHECK FOR A NEW 1200A 120/208 V 3 PHASE 4 WIRE SERVICE WITH TWO DISCONNECTS RATED AT 800A AND 400A. SCOPE OF WORK INCLUDES 40 (100A)  RESIDENTIAL PANELS, 2 (100A) HOUSE PANELS, AND 1 ELEVATOR AT 40HP. TOTAL AFFECTED AREA FOR T-24 ENERGY COMPLIANCE IS 19762 SQAURE FEET. BUILDILG PERMIT NUMBER: 18010-10000-06160.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18605	14041-20000-08347	20932 W CANTARA ST	91304	3	189B109    55	2109007028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.21816	-118.5899	PV1.  Intall for 4kw roofmounted PV system, interconnected with main pannel. Transformerless inverter with power optimizer; Solaredge SE3800A, 16 modules Canadian Solar CS60-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18606	10041-10000-12795	10250 W SANTA MONICA BLVD # 10	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	10/05/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IMPROVEMENT IN STORE SPACE #10 PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18607	19041-20000-34876	644 1/4 N COMMONWEALTH AVE	90004	13	142-5A201 373	5539027033	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	08/12/2020 12:00:00 AM	PIN	34.08302572	-118.28508947	POWER AND ENERGY PLAN CHECK  1200A SERVICE AND T24 INCLUDED. TOTAL SQUARE FOOTAGE  OUT DOOR LIGHTING= 3332 SFTract# TR 735859	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18608	16041-20000-15461	1611 S PACIFIC AVE	90291	11	106-5A143  28	4226009022	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	33.98732	-118.47221	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO A RESTAURANT. EGGSLUT. 998 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18609	14041-20001-20563	11351 N DRONFIELD AVE	91331	7	210B165     6	2532009009	A2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM			PC Approved	10/17/2014 12:00:00 AM	ADDRESS	34.27673	-118.4036	Fee for expedite only.******New building roof mounted PV system with system 57.25KW for new school.Note: The other PV system (68.75KW) is carport roof mounted system is under 14041-20000-20567.  Both PV systems are on the same plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18610	11041-20001-02943	1100 S GLENDON AVE 12TH FL	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM			PC Approved	03/18/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	Supplemental  changes from previously approved plans.  Install general lighting.  Plan check for energy only.*****PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING TENANT IMPROVEMENT ON 12TH FLOOR*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18611	15041-20000-24862	13360 W BERG ST	91342	7	228B157   266	2511010029	R1-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.3237	-118.42323	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18612	18041-10001-05286	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Changes to approved set, scope of work includes revising the load descriptions, scope of work also includes revised circuit names. Note this is a LAX project Note the master permit has been issued: 18041-30000-05286Orginal scope:Plan check for power and energy at LAX Project 5 T2 Enabling(Termimal 2) New power and lighting added for new BHS(Baggage Handling System ) rearrangement of spaces at level 1. New power added  for power seating at level 3. Total area: 6,625 sq ft. B#18014-1000-00667	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18613	13041-10000-31545	18736 W LULL ST	91335	3	186B121    95	2103016031	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.20921	-118.54189	PV1, Install 6.5 kW DC roof-mounted solar array for 1-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 26 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18614	18041-20000-07679	13934 W VAN NUYS BLVD	91331	6	204B153   517	2645002022	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.25552	-118.43629	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the replacement of existing fixtures with LED fixtures. Total lighting area = 17,700 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18615	19041-10000-32397	8840 N CORBIN AVE	91324	12	195B117    64	2783025092	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			Reviewed by Supervisor	08/27/2019 12:00:00 AM	ADDRESS	34.23069	-118.56211	POWER AND ENERGY PLAN CHECK FOR A TI TO A RETAIL STORE (TARGET). SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL NEW CONNECTED LOAD IS GREATER THAT 400A. TOTAL AFFECTED AREA IS 87,528 SQ-FT.BULDING PERMIT: 19016-10000-06566	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18616	17041-10000-37539	990 N WESTERN AVE	90732	15	021B193   200	7445011011	C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Info Complete	10/18/2017 12:00:00 AM	ADDRESS	33.75171	-118.3088	T-24 plan check to an existing market/retail in a gas station. Scope of work includes expanding the market space. Market is not located in the hazardous area. Total sq. ft. 1475.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18617	17041-10000-20183	735 S FIGUEROA ST 133	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.04878	-118.26079	Title 24 plan check.  T.I. to existing restaurant space.  New lighting in sushi bar area.       Building permit #17016-10000-09311	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18618	11041-10000-02272	4716 S LINCOLN BLVD	90292	11	105B153   149	4224014018	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	33.98012	-118.43824	Change of use from Retail to Fast Food. Plan Check is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18619	15041-20000-20108	7822 N RADFORD AVE	91605	6	189B169   625	2310023025	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.21261	-118.39201	Installation of new roof mounted solar PV array.  Total system size = 4.085 kWac.  Microinverter system with two branch circuits.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18620	11041-10000-09558	851 S GRAND AVE	90017	9	127-5A209  54	5144020012	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.04476	-118.25923	T.I.  EXISTING HISTORICAL HIGH RISE BUILDING.  TI TO BE DONE ON THE ROOF OF THE BUILDING.  BUILDING DOES NOT HAVE GENERATOR.  ALL EMERGENCY LIGHTS AND EXIT SIGNS ARE BATTERY BACK UP EQUIPMENT.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18621	11041-20000-18688	21800 W OXNARD ST	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	12/01/2011 12:00:00 AM	ADDRESS	34.17898	-118.60253	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT AT THE LOBBY IN AN (E) OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18622	14041-20000-11025	2120 S 5TH AVE	90018	10	126B189  1323	5060025016	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.03738	-118.3223	Roof mounted PV system with Microinverters.  System size 2.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18623	12041-10000-21198	2015 S LONG BEACH AVE WEST	90011	9	118-5A213 143	5118025001	M1-1	East Los Angeles	Southeast Los Angeles			2270.10	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM				AT A UNMANNED GAS/FILLING STATION, REPLACING FUEL DISPENSERS, CANOPY LUMINAIRES, ABOVE GRADE FUEL TANK, AND NEW PANELBOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18624	17041-10001-01013	14701 W VENTURA BLVD	91403	4	166-5A149  17	2265001001	C2-1L, [Q]R3P-1, [Q]R3P-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.15183	-118.45322	05-03-2017 Changes to an approved set of plan. Changes include lighting fixture layout. Changes has been clouded as delta 4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18625	11041-10002-10894	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			PC Approved	03/21/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	"Plans are revised to show that  heat detectors at the gate bridge/building junction are monitored to provide compatibility with existing FA system.Sheet FA-OO.4C HAS A DRAWING SHOWING THE WIRING OF THE COMPLETE FA SYSTEM CONSISTING OF THE CORE AND GATE INSTALL A NEW FIRE ALARM SYSTEM IN THE ""BRADLEY WEST CORE"" OF THE ""TOM BRADLEY"" BUILDING IN LAX."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18626	14041-20001-25415	6638 N ENCINO AVE	91406	6	180B129   299	2229011034	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM			PC Approved	09/20/2014 12:00:00 AM	ADDRESS	34.19154	-118.51408	Expedited plan check per applicant request.  PV1.  Install 12.75 kW roof-mounted, utility-interactive PV system.  Transformerless inverters with DC-DC converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18627	14041-20000-16306	13540 N VIA SANTA CLARA	91342	7	228B165    83	2581006***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	PIN	34.31828079	-118.39860083	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18628	12041-10000-09472	3150 W WILSHIRE BLVD	90010	10	132B197   112	5077010023	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Closed	11/20/2012 12:00:00 AM	ADDRESS	34.06163	-118.29086	3000A temporary service for construction.(New 23-story 200-unit apartment and  29-story 264-unit apartment over retail/restaurant and parking garage. Paralle Design Permitting Program 30% submittal, zoning only, no disabled acces, no green, no life safety, no structural.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18629	16041-20000-37288	10130 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.25424	-118.57964	Service upgrade/consolidation of (2) single/three-phase services into (1) 120/240V three-phase service.   Core and shell.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18630	14041-20000-05893	1055 W 7TH ST 14TH FLR	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.0507	-118.26334	pc for t24 energy only. existing offices. new lighting. work done on 14th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18631	17041-20000-26751	11807 W LAUREL HILLS ROAD	91604	2	159B169    70	2377004020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM			Reviewed by Supervisor	08/15/2017 12:00:00 AM	ADDRESS	34.13566	-118.38965	Plan check for solar pv system, roof-mounted on SFD.11.4kW ungrounded system. (40) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18632	19041-10000-52507	445 S FIGUEROA ST 10th floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	TITLE 24 ENERGY PLAN CHECK ONLY. TOTAL EFFECTIVE AREA: 14135 S.F	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18633	19041-20001-22673	6053 W CENTURY BLVD 11TH FL	90045	11	093B169   305	4124030902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	33.94648	-118.38998	11/18/19CHANGES TO APPROVED SET DELTA 5 ONLY CHANGES TO LIGHTING FIXTURES.<<<T24 ONLY PLAN CHECK POWER AND ENERGY ONLY IN EXISTING HIGH RISE COMMERCIAL 11TH FLOOR. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 15,452 SF>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18634	14041-20000-03565	11166 W LUCERNE AVE	90230	11	111B165   165	4215005005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.00102	-118.40183	PV1 SINGLE FAMILY DWELLING. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18635	14041-20000-04059	11747 N RICASOLI WAY	91326	12	216B109    82	2701077026	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Expired	03/29/2016 12:00:00 AM	ADDRESS	34.28609	-118.58475	Roof mounted PV system with 6 KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18636	14041-20002-24073	23723 W SANDALWOOD ST	91307	12	186B093   315	2027017018	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			PC Approved	10/29/2014 12:00:00 AM	ADDRESS	34.20561	-118.64344	fee charge is $0.00 by state senate bill no. 1222revisions to an approved set of plans.  removal of two trina solar modules tsm-255pa.PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 8.8kW.(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(36) Trina solar TSM-255PA05.18 pv modules(36) SolarEdge P300 power optimizers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18637	13041-10000-20709	3495 S STONER AVE	90066	11	114B153    43	4249015009	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2013 12:00:00 AM			Verifications in Progress	10/18/2013 12:00:00 AM	ADDRESS	34.01248	-118.4331	pc for power. battery backup system for SFD (solar is existing): tesla battery bank (10KWH) and midnite solar e-panel  #MNEXW250SC indoor e-panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18638	12041-10000-05947	515 S FLOWER ST 5th Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check T24 Energy/Emergency lighting for office TI on the 5th floor in high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18639	10041-10000-24427	630 W 6TH ST Unit #116C	90017	9	129A209   260	5144005***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	04/11/2011 12:00:00 AM	ADDRESS	34.04916	-118.25624	TI IN AN EXISTING COMMERCIAL AREA (PIZZERIA URBANO) ON THE 1ST FLOOR IN UNIT # 116C. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18640	17041-10000-42159	641 W 40TH PL	90037	9	115-5A201  92	5019025055	C2-1, R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Public Safety Only			11/21/2017 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.01065	-118.28546	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18641	14041-10000-14712	2200 W PICO BLVD	90006	1	129A201   236	5056008012	C2-1VL	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.04716	-118.28441	tenant improvement in taco shopplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18642	16041-10000-01997	1230 S OLIVE ST	90015	14	126A207   209	5139024016	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.03857	-118.26278	NEW FIRE ALARM FOR NEW 7 STORY MIX-USE 361 UNIT APARTMENT BUILDING WITH TWO UNDERGROUND PARKING LEVELS.  (2) COMMUNICATION PANEL (7) CONTROL PANEL (1) ALARM PANEL (1067) DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18643	19041-10000-51261	2474 E PORTER ST	90021	14	121-5A219 114	5168028008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.0265	-118.2274	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18644	17041-10001-12915	225 N VERMONT AVE	90004	13	138B197   512	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			Corrections Issued	05/16/2017 12:00:00 AM	ADDRESS	34.07529	-118.29188	TI TO EXISTING SHELL SPACE TO CREATE 3 VANILLA SHELL SPACE. INSTALLING LIGHTING AND PLUGS FOR FUTURE TI. PC FOR T24 ENERGY ONLY.PC FOR COLLECTIVE OF ALL UNITS. 3 PERMITS CURRENTLY ON JOB. OTHER 2 FEES COLLECTED;17041-10000-12923 17041-10000-12924B#16016-10000-20859	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18645	19041-20000-14766	9215 N CRANFORD AVE unt 5	91331	6	198B161   717	2629027071	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Issued	05/01/2019 12:00:00 AM	ADDRESS	34.23666	-118.41261	first time tenant.  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18646	14041-10001-19897	12836 W HORTENSE ST	91604	2	168B161   792	2362019016	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM			PC Approved	08/06/2014 12:00:00 AM	ADDRESS	34.15481	-118.41299	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 10.46 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(41) MODUES: TRINA SOLAR TSM -255PA05.18(2) INVERTER(s): SE5000-US-ZB-U & SE3800A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18647	14041-20000-10839	4958 N CARPENTER AVE	91607	2	171B169   846	2355013017	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.161	-118.3909	PV1 SINGLE FAMILY DWELLING USING ENPHASE MICROINVERTER ENPHASE M215. USING STANDARD PLAN. TOTAL SYSTEM SIZE 5.18KW AC USING 24 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18648	14041-20001-01721	3575 N WONDER VIEW DR	90068	4	159B185    51	5577004008	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.13282	-118.33656	(((EXPEDITE FEES))))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18649	15041-10001-33459	8821 S PERSHING DR # 1	90293	11	093B153   150	4117028029	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Approved	11/25/2015 12:00:00 AM	ADDRESS	33.9532	-118.44046	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL NEW 5.3 KW DC ROOF-MOUNTED SOLAR ARRAY ON #2 UNIT APRTMENT OF AN APARTMENT BUILDING.(20) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.6-OUTD-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18650	11041-10000-09087	11922 S VERMONT AVE	90044	15	084B197   351	6088020013	C2-1L	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM			PC Info Complete	07/21/2011 12:00:00 AM	ADDRESS	33.92425	-118.29139	NEW GAS STATION.  INSTALLING FUEILING TANKS, TRANSFORMERS, AND PANELS.FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18651	13041-10001-30912	1201 N GARBO LN	90038	4	144B185  1348	5532004041	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	PIN	34.09270578	-118.33667375	Expedited RSES plan check per applicant request.(((PV1, Install 1.59 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One  AURORA PV1-3.0-OUTD-S-US. 6 modules: Suniva OPT265-60-4-1B0.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18652	18041-10000-24574	133 W 80TH ST	90003	9	099B201   654	6031024019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Issued	07/02/2018 12:00:00 AM	ADDRESS	33.96703	-118.27514	NEW PV 1 ROOF MOUNTED SOLAR EQUIPMENT USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (10) MODULES AND (1) 3.0KW INVERTER. TOTAL SIZE IS 3.0KWAC/ 2.95KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18653	14041-20000-32079	8741 W APPERSON ST	91040	7	204B189   620	2546003018	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.25584	-118.32359	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.5 KW. MICROINVERTER NON STANDARD PLAN. (22) ENPHASE MICRO INVERTER(22) CANDIAN SOLAR 250W	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18654	19041-10000-07822	19701 S HAMILTON AVE #160	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	33.85221	-118.28625	TI IN AN EXISTING LOW RISE OFFICE BULDING IN SUITE # 160. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-36437	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18655	13041-10000-26064	5206 N BELLAIRE AVE	91607	2	171B161   530	2346019010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.16517	-118.40927	PV1.  Install 11.5 kW DC roof-mounted photovoltaic system interconnect with main service panel.  2 transformerless inverters: Power-One Aurora PVI-5000-OUTD-US.  46 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18656	15041-20000-14320	624 S GRAND AVE Suite 1405	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	PIN	34.04778206	-118.25563275	Title 24 plan check only.  Total area = 5,200 sq. ft.  T.I. to existing commercial highrise office space.  New lighitng and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18657	18041-10000-36166	6527 W 82ND ST	90045	11	099B165   931	4108006019	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	33.96469	-118.40276	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.675 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18658	15041-10000-11845	21900 W BURBANK BLVD SUITE 100	91367	3	174B105    46	2146007120	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.17189	-118.60404	TI TO AN EXISTING THREE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2967.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18659	18041-20000-02118	11051 W CALIFA ST	91601	2	177B173  1419	2337021014	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.03	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.17771	-118.3721	PV1.  Install 12.60 kW DC//11.2 kW AC roof mounted grid tied PV system.  (35) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18660	17041-10000-00228	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.07196	-118.24719	PC FOR POWER AND ENERGY. NEW LIGHTING FOR LEFT AND RIGHT FIELD PAVILIONS IN DODGER STADIUM. OCCPANCY >100. T24 MIXED OF TAILORED AND AREA CATEGORY. TOTAL AREA 20588 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18661	19041-10000-30871	2661 W PICO BLVD	90006	1	129B197  1030	5078032026	C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.04741	-118.29636	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18662	13041-20000-35437	12449-12451 W VICTORY BLVD	91606	2	180B165   705	2333003032	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Info Complete	01/10/2014 12:00:00 AM	ADDRESS	34.18684	-118.40477	ADDITION OF 2,121 SF OF RETAIL SPACE TO CONNECT TWO (E) STRUCTURE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18663	15041-10000-06487	4335 S WOODLAWN AVE	90011	9	114A205   449	5113036015	C2-1VL	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.00457	-118.27303	PV2, INSTALL  A NEW ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 18.480KWdc / 15.2KWac (66) MODULES-LDK 280P-24 (2) INVERTERS: DELTA -SOLIVIA 7.6TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18664	15041-10000-29028	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	ALTERATIONS IN TENANT SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18665	13041-20000-22665	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	RENOVATION OF LIGHTING IN CORRIDOR. PC FOR T24 ENERGY ONLY. TOTAL AREA 2116 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18666	16041-20000-36560	11285 W GOSS ST	91352	6	192B173   329	2632006007	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.22321	-118.37713	800A 120/240V three-phase service equipment upgrade for a commercial warehouse.  Utility transformer existing per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18667	17041-10002-14071	8232 N CANTERBURY AVE	91352	2	192B161   208	2304002001	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			No Progress	06/14/2017 12:00:00 AM	ADDRESS	34.22085	-118.41717	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO WIRING DIAGRAM TO REMOVE NEUTRAL FROM CONNECTION INVERTER TO SUBPANEL. NO NEUTRAL PROVIDED WITH MODULE.ALL LUGS SHALL BE 75 DEGREE RATED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18668	19041-10000-03897	6080 W CENTER DR GROUND-FLOOR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	ENERGY PLAN CHECK FOR THE GROUND FLOOR OF A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 3,806-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18669	13041-10000-09466	4636 S LINCOLN BLVD	90292	11	105B153   124	4224014023	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM			PC Approved	05/13/2013 12:00:00 AM	ADDRESS	33.98239	-118.44062	AUTO RETAIL TI TO EXISTING 1 STORY CHANGING LIGHTSINTERIOR TI OF (E) AUTO DEALERSHIP: REMOVE (E) NON-BEARING WALLS & (N) T-BAR CEILING SYSTEM. (PC REFER TO COMMENTS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18670	16041-10001-00519	12758 W OTTOMAN ST	91331	6	198B161   175	2629024004	R1-1	North Valley	Sun Valley - La Tuna Canyon			1212.10	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.24087	-118.41141	PC FOR SOLAR PV SYSTEM. THIS APPLICATION WILL COVER PERMIT FEES FOR CHANGES TO ORIGINAL PERMIT. CHANGE INCLUDES DIFFERENT DC MODULE TYPES. NOW SYSTEM USES 260W MODULES. STILL USING 3.8KW INVERTER WITH POWER OPTIMIZERS 4.94KW DC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18671	18041-30000-19482	5330 W LOMA LINDA AVE 1-8	90027	13	148-5A195  35	5544009021	R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Apartment			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.10274	-118.30604	Plan check for a fire alarm system for 4-story, 8-unit apartment building. Scope include (33) fire alarm devices, (1) power supply and (1) fire alarm control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18672	17041-10000-15174	1555 W SUNSET BLVD	90026	13	139-5A209 170	5419028004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.07667	-118.25669	Plan check for power only for service upgrade from 200A to 600A. This scope is only to provide the service and panels. Branch circuit and T24 is under separate TI plan (per Enginner)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18673	17041-10000-02619	333 S GRAND AVE STE#1600	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC for energy only for TI on 16th floor of a high rise building. New lighting and power. Total area: 4835.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18674	11041-20000-13161	601 S FIGUEROA ST 40th Floor	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM	09/12/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check T24 Energy ( general/emergency) lighting for office TI on the 40th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18675	13041-10000-16982	14932 W BLEEKER ST	91342	7	216B149    59	2611019021	RS-1	North Valley	Sylmar	Sylmar	YES	1066.48	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.29219	-118.45616	MODIFICATION TO APPROVED SET OF PLANS IN REFERENCE TO 13041-10000-12496:, CHANGES MADE TO LOCATION OF EQUIPMENT. CHANGES MADE TO SHEET PV01 AND PV02.********************************************************************************13041-10000-12496: PV1 9.3KW 38PANELS (TSM-245PA05.08 ). 2 INV (inverters SE3800A-US and  optimizers OP250LV). SOLAREDGE/OPTIMIZERS ROOFMount. NONSTandarD plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18676	19041-10000-36238	1999 S AVENUE OF THE STARS #3000	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	ENERGY PC FOR T.I. TO THE (E) OFFICE. (4909SQ.FT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18677	15041-20001-08391	5340 S ALLA ROAD	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	ADDRESS	33.9773	-118.42567	Changes to an Approve set. Changes made under delta 1. Adding receptacles and replacing lighting fixtures. fees paid under pcis#15041-20000-08391/E15VN00709(((Plan check for Title 24 only. Project space an office building. Scope of work is a tenant improvement. Total lighting area = 5,945 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18678	13041-10000-02951	14006 W RIVERSIDE DR # 74	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	IMPROVEMENT IN EXISTING RETAIL STORE-LIGHTING AND NEW CIRCUITSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18679	15041-10001-20349	19602 W LANARK ST	91335	3	189B117    95	2105003006	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	34.21785	-118.56051	4/18/16: Supplemental PC only, removed 6 panels and comply with 3' Fire setback. No new aquipment, Permit under master 15041-10000-20349. Zero fees due per California Senate Bill 1222.<<PV1, INSTALL 9.81 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (30) MODULES: SUNPOWER SPR327NE-WHT-D(3) INVERTERS: SMA SB3000TL-US-22>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18680	16041-20000-36489	355 S MUIRFIELD ROAD	90020	4	135B185   215	5505009007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM			PC Info Complete	11/14/2016 12:00:00 AM	ADDRESS	34.06741	-118.32894	Plan check for power only. Project site is an existing 2-story single-family dwelling. Project scope is a completely new electrical service and new electrical distribution equipment.Note: Building application has been generated under 15030-10000-05942	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18681	15041-20000-27966	6749 N FALLBROOK AVE #915	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.1925	-118.62407	Plan check for core and shell power only in existing space 500A @ 480V transformer step down to 600A @208V.	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
18682	19041-20000-23024	6200 N CANOGA AVE	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Issued	12/16/2019 12:00:00 AM	ADDRESS	34.1833	-118.59719	PV3.  Install roof mounted PV system sized 199.8 kW AC interconnected with MSP (line side tap). (612) modules(6) 33.3KW inverters$0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18683	13041-10000-26931	12770 W CASWELL AVE UNITS 1-11	90066	11	111B153  1140	4236019015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			12/20/2013 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	33.99766	-118.43804	PLAN CHECK FOR POWER AND ENERGY FOR A NEW FOUR STORY MULTI-UNIT APARTMENT BUILDING. 11 UNITS TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18684	13041-10002-06017	9301 N TAMPA AVE UNIT 192	91324	12	198B117    99	2761037004	R1-1	North Valley	Reseda - West Van Nuys	Tarzana		1133.01	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	((Changes to approved set.  Changes to fixture schedule and title 24 forms to reflect current design lighting.  only one circuit (22) on the lighting panel instead of 5 ckts)) Original Description: PC FOR TITLE 24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT FOR RETAIL/MERCANTILE SPACE. SQUARE FOOTAGE IS 4561. NOTE: ALL PERMITS FOR TITLE 24 APPLICATIONS SHALL BE OBTAINED THROUGH ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18685	16041-20000-09094	8221 W SUNSET BLVD	90046	4	147B173   195	5555030010	R4-1D	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.09811	-118.3683	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EXISTING PREP KITCHEN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18686	19041-10000-49550	3030 N ANDRITA ST	90065	13	154-5A213 199	5458008013	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	11/19/2020 12:00:00 AM		Permit Finaled	07/02/2021 12:00:00 AM	ADDRESS	34.11608	-118.24584	NEW ADDED PANELS TO EXISTING SERVICE. TOTAL ADDED OVER 400. AREA OF SCOPE IS (5700)SF.***100% PDPP partial plan check submittal for Structural Plan Check only***Change of use and expansion to Sound Stage with tenant improvements and seismic upgrade to (E) 1-story production studio	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18687	19041-20000-40800	1011 S FIGUEROA ST B-101	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.04476	-118.26452	Tenant Improvement to existing Restaurant plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18688	19041-10000-52152	7200 W FRANKLIN AVE	90046	4	147B181    24	5548001194	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.10326	-118.34594	"TENANT IMPROVEMENT IN AN EXISTING APARTMENT LOBBY AND ""LEASING OFFICE"" ON THE FIRST FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 598 SFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18689	18041-10000-39509	444 S FLOWER ST FL 13	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLAN CHECK FOR T24 ONLY, TI ON RESTROOMS ON (E) 13TH FLOOR. TOLTAL AREA 535 SQ.FT(B# 17016-10000-19727)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18690	12041-20000-18505	601 S FIGUEROA ST	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I. to a high rise building on 17th floor, suite 1750.  Install general/emergency lighting.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18691	11041-10000-23452	20600 W VENTURA BLVD South-1-217	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			11/03/2011 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	South Building of a New 217 unit Apartment building.  Building Permit is on 11010-10000-01956	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18692	10041-10000-04280	5301 W WASHINGTON BLVD	90019	10	126B177   971	5064006001	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	PIN	34.04061904	-118.35791755	Electrical plan check for electrical and energy.  Modification to seperate fire alarm system has been filed. For change of use from existing  2-story warehouse to private charter school.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18693	18041-20000-33028	2114 N RIDGEMONT DR	90046	4	150B169   439	5564028003	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.10941	-118.38977	Plan check for PV and battery back up system, PV system size: 3.25 KW with 10 modules and 1 inverter(3.0KW) and Battery Back Up System size: 27 kWh win 2 batteries Tesla 2.0(13.5kWh).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18694	18041-10000-16021	1026 N SWARTHMORE AVE #3-103	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.04772	-118.52529	"PLAN CHECK FOR POWER AND ENERGY FOR A FIRST TIME TENANT FOR RETAIL SPACE ""VINCE"" WITHIN PACIFIC PALISADES. SCOPE INCLUDES CONNECTING TO AN EXISTING 800A DISTRIBUTION EQUIPMENT WITH 2 NEW PANELS AND 45KVA TRANSFORMER. TOTAL AFFECTED AREA 2951 SQ. FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18695	11041-10002-19246	6701 N ETON AVE 1-298	91303	3	180B105    27	2148030035	(WC)C/I-60/1.0	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			01/28/2013 12:00:00 AM			PC Approved	01/28/2013 12:00:00 AM	ADDRESS	34.19217	-118.59564	Revised permitted set of plans- added outlets to existing circuits 2nd floor fitness room;in electrical a remove inverter subpanel and decreased inverter fromm 8KVA to 6KVA;subpanel is relocatedt to garage main electrical room and connect to panel supplied by inverter in that room. inverter is increased 10KVA  Changes to previosly approved sets, , changes to title 24, feders and interior lightings.   No new ckt or panels. Revise elevator 1, 2, and 3, remove load from existing panels and relocate receptacle and luminaires. EPC is for delta I only. 9-13-12   (((((((((((((((((NEW FIVE-STORY, TYPE-III-A, 298-UNIT APARTMENT WITH ATTACHED PKG GARAGE (Automatic fire srpinkler throughout for the story increase). See separate permit  for attached parking garage.Need to file a variance to separate the FA plans from the electrical plans.Plan check fees were determined by client.))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18696	19041-10000-37427	1833 W COLORADO BLVD	90041	14	162A225    81	5669024028	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM			PC Approved	09/18/2019 12:00:00 AM	ADDRESS	34.1395	-118.20719	Energy plan check for a RESTROOMS T.I located in a restaurant. Scope includes new lighting and equipment with a total lighting area of 173-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18697	19041-20001-24147	5242 W 104TH ST	90045	11	090B173   290	4129035013	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM			PC Approved	09/16/2019 12:00:00 AM	ADDRESS	33.94183	-118.37188	EXPEDITE PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING WAREHOUSE. SYSTEM SIZE IS 97.3KW DC/100KW AC/87.1 KW AC CEC. SCOPE OF WORK INCLUDES (278) SUNPOWER PV MODULES WITH (141) P850 OPTIMIZERS, A SE100KUS INVERTER, AND A 72KVA TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18698	17041-20000-13500	421 W 7TH ST	90014	14	129A209   197	5144003026	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	34.04631	-118.25481	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 226 sq. ft.Note: Building application has been generated under 17016-20000-09982	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18699	17041-30000-38698	633 W 5TH ST Suite 5700	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project stie is an existing tenant space in a high-rsie building. Project scope is a tenant improvement. Total lighting area = 5,580 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18700	19041-10000-05761	4200 S BROADWAY	90037	9	114A203   152	5111017025	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	34.00723	-118.27813	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18701	18041-10005-15820	20209 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM			PC Approved	05/10/2019 12:00:00 AM	ADDRESS	34.27509	-118.57388	DELTA 11 CHANGES ONLY - CHANGES INCLUDE ADDITION OF CIRCUITS AND RELOCATION OF CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18702	13041-10001-27088	7900 N CASABA AVE	91306	3	189B113   739	2107025031	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.21408	-118.57667	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. STANDARD PLAN. SYSTEM SIZE: 8.25 kW.(33) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18703	13041-20000-00575	17617 W WILLARD ST PV-1	91325	12	192B129   625	2201007003	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM			PC Info Complete	01/22/2013 12:00:00 AM	ADDRESS	34.21879	-118.51701	PV-1. 2.94 kW. Saban Residence. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18704	10041-20001-09133	145 N LA BREA AVE A-F	90036	5	138B181   632	5513002010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.07488	-118.34438	change point of connection of pv system from main swbd to new 400 panel all other work is existing under original permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18705	13041-10000-01417	380 WORLD WAY T19	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	First time tenant space T19 (DUTY FREE SHOP) on 4th floor at Bradly West Terminal LAX.  Install tranformer, panels, and branch circuits.  Plan check for power and energy.   Filed for variance to separate fire alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18706	19041-10001-47174	12812 N JOLETTE AVE	91344	12	222B129   194	2602012019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.303	-118.51258	PLAN CHECK ONLY. CHANGES TO APPROVED SET. CHANGES TO THE MODULES LAYOUT ON THE ROOF. NO OTHER CHANGES APPLIED. PV1, New solar system using microinverters. (21) modules and microinverters. Total system size 6.09 kwac/ 7.56 kwdc	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18707	11041-10002-24378	948 E LAKE ST BLDG 4-2	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			10/03/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.001	-118.46101	Lincoln Place Apartment Building Project.  New 2-story apt. building with 7 units.  (((((((((((((((((((((((((((((((((((((  Addition of 3 E.V chargers. M.Z  ))))))))))))))))))))))))))(((((((    10-3-14  mz installation of 5 new 20 amps E.V.)))))))))))))))	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18708	15041-20000-30757	20801 W VENTURA BLVD	91364	3	171B109    62	2166033045	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.16663	-118.58589	Title 24 plan check only.  Total area = 98,050 sq. ft.     T.I. to sales floor area of existing target.  Most lighting is to remain existing.  Total new load is less than 400 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18709	18041-10000-06922	100 WORLD WAY T132	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	FIRST TENANT IN NEW RETAIL SPACE AT LAX TERMINAL 1 CONCOURSE LEVPLAN CHECK FOR POWER AND LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18710	17041-20001-00110	10649 W JIMENEZ ST	91342	7	210B177    27	2529011021	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM			PC Approved	01/20/2017 12:00:00 AM	ADDRESS	34.27595	-118.36294	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD and detached garage. Interconnect with a 200A MSP.7.6kW ungrounded system. (34) 255W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18711	16041-10000-18541	5901 W CENTER DR	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM			Reviewed by Supervisor	07/01/2016 12:00:00 AM	ADDRESS	33.97509	-118.38703	NEW 5 STORY TYPE III-A  280 UNIT  APARTMENT BUILDING WITH ONE LEVEL MEZZANINE OVER  2 STORY TYPE I-A   PARKING GARAGE  & COMMON USES ABOVE. 1 LEVEL OF SUBTERRANEAN PARKING GARAGE .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18712	18041-20000-41494	4751 E YORK BLVD	90042	14	156A223   143	5476020024	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.12255	-118.2118	Plan check for Title 24 only in existing space T.I. Total area: 2599 sq ft. B#18016-20000-35128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18713	11041-20000-16369	18919 W VENTURA BLVD	91356	11	174B121   412	2161001041	C2-1VL, D	South Valley				1394.00	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.17261	-118.54549	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE TO DENTAL OFFICE.Claim for refund denied 12/13/11 plan were done on time and were expedited claim # 110134	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18714	16041-20000-11848	419 N MCCADDEN PL	90004	4	141B185  1149	5524032015	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.07892	-118.33729	Plan check for a PV1 roof-mounted PV system. System size is 5.8 kWac and consists of (16) ac modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18715	13041-10000-26299	23368 W BURBANK BLVD	91367	3	174B093   373	2044001001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.17171	-118.63605	Permit fee $0, SB 1222 cap on the permits for rooftop solar at $500. PV1 ROOF-MOUNTED PHOTOVOLTAIC SYSTEM 14KW DC WITH TRANSFORMERLESS INVERTERS (56) MODULES: TRINA #TSM-250PA05.18(2) POWER-ONE #AURORA PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18716	17041-10000-02030	12417 W SATICOY ST	91605	2	186B165   237	2307017013	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.20862	-118.40366	PC FOR ROOF MOUNTED PV SYSTEMSYSTEM  SIZE IS 6 KWAC INCLUDES CENTRAL INVERTER FRONIUS PRIMO 6.0-1  22 MODULES  AXITEC AXIPOWE AC -265P	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18717	18041-10000-13940	2701 S VERMONT AVE	90007	8	123B197  1361	5054032026	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.0303	-118.29178	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18718	17041-20001-35134	6804 S CENTINELA AVE	90230	11	105B165   427	4220014023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	08/14/2020 12:00:00 AM		Permit Finaled	08/18/2020 12:00:00 AM	ADDRESS	33.98417	-118.40202	12-20-2019 Changes to an approved set of plan, Changes include addition of circuits, addition of lighting, revised single line diagram, update service load calculation. All changes has been clouded as delta 9.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18719	19041-20000-25319	4712 N CONCHITA WAY	91356	3	168B117   342	2178013028	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM			Verifications in Progress	04/30/2021 12:00:00 AM	ADDRESS	34.15604	-118.56013	PLAN CHECK AT APPLICANT'S REQUEST FOR SFD REMODEL. PLAN CHECK ONLY. POWER AND ENERGY. NEW 400A SERVICE, 400A MDP, (2) 200A HP, AND A 400A HP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18720	12041-10000-22873	2970 W OLYMPIC BLVD	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	T.I. for office space suite# 102, future medical offices #103 and 104.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18721	19041-10000-53163	10105 N COMMERCE AVE	91042	7	204B197  1062	2565013101	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			Corrections Issued	12/23/2019 12:00:00 AM	ADDRESS	34.25251	-118.28882	CHANGES TO AN APPROVED SET UNDER DELTA 3. SCOPE OF WORK INCLUDES CHANGES TO TITLE 24 FIXTURES AND CALCULATIONSSCOPE OF WORK INCLUDES ALTERNATIONS TO LIGHTING FIXTURES INDOOR AND OUTDOOR. TOTAL AFFECTED AREA: 8,051 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18722	19041-10000-49850	121 S CARMELINA AVE	90049	11	132B141   586	4405036036	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.05703	-118.48073	$0 fee due to AB1414. NEW ROOFTOP PV1 SOLAR SYSTEM CONSIST OF 57 MODULES (CANADIAN SOLAR 330W), 57 OPTIMIZERS (SE P370) WITH 2 CHENTRAL INVERTERS (SE7600A-US AND SE10000H-US). SYSTEM SIZE IS 18.8KWDC 17.6KWAC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18723	13041-20000-20595	6035 N VANTAGE AVE	91606	2	177B165   607	2333013045	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.18045	-118.39775	New Enphase PV system for a single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18724	18041-20000-42300	3051 S DANALDA DR	90064	5	123B165   139	4316015015	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Issued	11/05/2018 12:00:00 AM	ADDRESS	34.03642	-118.40378	Plan check for PV roof mounted system, system size: 16KW DC, 9.84KW AC with 41 PV Modules and 41 Microinverters connected to MSP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18725	12041-10000-11425	4300 N PERLITA AVE	90039	13	159B205   450	5594010013	(T)(Q)RD2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.13148	-118.26801	Plan check for new roof mounted 1.2KW Enphase M215 Microinverter photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18726	10041-20000-19509	1435 W 7TH ST	90732	15	015B193   410	7459001016	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	10/13/2011 12:00:00 AM	ADDRESS	33.7377	-118.30896	Plan check for new installation of 15.75 KW Photovoltaic System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18727	13041-20000-25070	19332 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.23457	-118.55484	INSTALLING TWO 400A SECTIONS TO NEW 800A SERVICE. RUNNING CONDUITS WITH CONDUCTORS TO SHELL BUILDING. NO LOAD IS TO BE ADDED AT THIS TIME. THE FUTURE TENANT REQUIRES FULL PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18728	15041-20000-30998	4244 N WOODCLIFF ROAD	91403	4	165A145    62	2281004002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Expired	10/25/2017 12:00:00 AM	ADDRESS	34.1479	-118.46709	Plan check for PV roof mounted system. System size: 10.0kW with 44 modules and 1 inverter(10kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18729	17041-10000-16180	1110 S MAPLE AVE	90015	14	124-5A209  68	5145023026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.03673	-118.25525	T24 ONLY, REPLACE (E) LIGHT FIXTUES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  15300 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18730	15041-20001-02511	3276 S STONER AVE	90066	11	117B153   502	4250006011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.01757	-118.43543	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 7.6KW AC USING TRANSFORMELRESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18731	14041-20000-11253	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.0344	-118.45642	TI in (E) commercial office space in single story building.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18732	19041-20000-51576	3510 N MULTIVIEW DR	90068	4	159B177   753	2427004003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.12805	-118.35965	PV1. INSTALL 9.57 KWDC PV SYSTEM WITH (33) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18733	19041-10000-11217	17081 W DEVONSHIRE ST BLDG A	91325	12	204B133    79	2695020030	[Q]C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	01/12/2022 12:00:00 AM	ADDRESS	34.2577	-118.50558	(1 SET OF PLANS WITH 3 APPLICATIONS) 1-3 FULL PLAN CHECK FOR NEW BLDG A  ADMINISTRATION BLDG  1 STORY. BUILDING A IS FED FROM BUILDING C ELECTRICAL SYSTEM.REFFER TO THE PERMIT NUMBERS BELOW. B-A# 19010-10000-01179E-A# 19041-10000-11217B-B# 19010-10000-01180E-B# 19041-10000-11215B-C# 19010-10000-01182E-C# 19041-10000-112211 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18734	11041-20000-04073	1200 W 7TH ST Ground-Level	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.05136	-118.26616	T.I. to existing high rise building.  Install general/emergency lighting in caferia area of ground level.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18735	18041-10001-19372	507 N GARDNER ST	90036	5	141B177  1105	5526026010	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM			PC Approved	07/24/2018 12:00:00 AM	ADDRESS	34.08056	-118.35334	INSTALL  NEW PV SYSTEM REATED 10.4KW WITH 32 MODULES ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18736	15041-10000-37242	534 N BAY VIEW AVE	90744	15	030B205  1427	7417023029	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	33.77614	-118.26968	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(23) KYOCERA 265 WATTS MODULES(2) PVI 3.0KW INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18737	12041-10000-20544	5153 N GOODLAND AVE	91607	5	171B161   549	2357012009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.16461	-118.41164	7.44 kw roof mounted solar for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18738	16041-20000-40567	20801 W VENTURA BLVD	91364	3	171B109    62	2166033052	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.16663	-118.58589	TI to (E) Target retail store.  Additional display lighting for liquor aisles.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18739	19041-10000-16387	12540 W SHERMAN WAY	91605	2	183B161    65	2324034019	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.20097	-118.40699	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18740	10041-10000-24445	1105 N GAFFEY ST	90731	15	021B197   377	7445008049	M1-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Expired	12/09/2011 12:00:00 AM	ADDRESS	33.75404	-118.29247	New under ground fuel storage tank. EPC is for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18741	15041-20001-26167	18000 W BULL CANYON ROAD	91344	12	219B129   497	2601025029	A1-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	34.29578	-118.52393	Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18742	14041-20000-12743	12852 W RUNWAY ROAD PV-2	90094	11	102B161  1221	4211033040	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	33.97543	-118.41892	Revisions to approved set approved under 13041-20000-24806.  See deltas 4 thru 8.  Change of module model, inverter manufacturer/model, and revision of service equipment to match current existing installation.  Other miscellaneous revisions.    (((PV-2. Plan check for PV system for community center. One 75kW inverter. Solar fees capped out during Submital therefore final fees = 0.00)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18743	13041-20000-27317	7274 W MELROSE AVE	90036	5	141B181   621	5525013005	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	10/02/2013 12:00:00 AM	PIN	34.0832633	-118.34830747	T-24 and emergency lighting plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18744	13041-10000-05747	380 WORLD WAY Space T64	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 803 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Scoreboard LA).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18745	19041-10002-03636	621 W ROSECRANS AVE	90248	15	075B201    35	6132006031	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Approved	09/06/2019 12:00:00 AM	ADDRESS	33.90205	-118.28562	REVISION TO AN APPROVED SET OF PV2. CHANGE UNDER DELTA 4 ONLY. CHANGE INCLUDES REARRANGING THE LAYOUT OF PV MODULES BUT THE AMOUNT OF THE MODULES REMAIN THE SAME. CHANGE ALSO INCLUDES CHANGING THE RAPID SHUT DOWN BOX MODEL.ORIIGINAL SCOPE: NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 246.01KWdc / 208KWac.(672)MODULES- 365W JAM72S01-365/PR(4)INVERTER-33KW HUAWEI (1)INVERTER-36KW HUAWEI (4)INVERTER-40KW HUAWEI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18746	16041-20000-25839	2728 N FLETCHER DR	90039	13	151-5A211  90	5436031015	[Q]C2-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Expired	09/07/2018 12:00:00 AM	ADDRESS	34.11066	-118.2508	Plan check for Title 24 only in existing space restaurant . Total area: 495 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18747	19041-10000-29981	5200 N LANKERSHIM BLVD 160	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC for Title 24 Energy Only. Scope include new lights and receptacles for an existing space. Total affected is 1,215SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18748	15041-10000-33435	550 W UPLAND AVE	90731	15	021B197   829	7448021023	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	33.75011	-118.28887	PV1, INSTALL NEW 3.18 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: KYOCERA KU2656ZPA(1) INVERTER:SOLAREDGE SE3000A-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18749	19041-10000-34082	5651 W 96TH ST	90045	11	093B169   132	4125021025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	33.94947	-118.38017	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18750	17041-20000-15485	13500 W HUBBARD ST	91342	7	225B157   825	2512001078	C4-1-K-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.30982	-118.42736	Plan check for energy only. New outdoor lighting for existing gas station and new self-service carwash. 9600sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18751	07041-10002-27331	5315 N BELLINGHAM AVE	91607		171B165   265	2347022015	[Q]R3-1		North Hollywood - Valley Village	Valley Village			Electrical	Electrical	Apartment			01/18/2011 12:00:00 AM			PC Approved	01/26/2011 12:00:00 AM	ADDRESS	34.16724	-118.39946	New 3-story 17-unit apartment building+ subterraneam garage. New 120/240 1Ph 3W 1200A service.  EPC: Power and Energy(T-24).PLAN CHK IS FOR AS-BUILT SET OF PLANS; OWNER TO TRANSFER ORIGINAL PERMIT TO NEW CONTRACTOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18752	11041-10000-20648	1049-1057 E ELKGROVE AVE BLDG 38	90291	11	111B145   504	4243003043	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.00181	-118.4592	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18753	16041-10000-20614	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			Reviewed by Supervisor	07/20/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER. RUNNING CONDUIT FOR EATALY TENANT. CONDUIT WILL BE INSTALLED THROUGH MACY'S STORE.Plans were recycled on 8/23/18 per permit expiration date 12/13/17	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18754	16041-10000-05400	22222 W VICTORY BLVD BLDG B	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUNDRY ROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18755	19041-20000-16065	11766 W WILSHIRE BLVD Ste 1701	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM			Not Ready to Issue	05/01/2019 12:00:00 AM	ADDRESS	34.04804	-118.46227	Commercial office TI in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18756	18041-20000-14824	20630 W WALNUT CIR	91326	12	219B109   358	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.29383	-118.58347	PC for rooftop solar for 3.84kW(ac)/4.02kW(dc) for SFD tract home. Installing 12 AC modules with AC disconnect.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18757	11041-10000-15420	153 N GLENDALE BLVD 1-4	90026	13	135A209   300	5159015032	C2-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Apartment			07/22/2011 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.06346	-118.26018	NEW 3 STORY 45 UNITS APARTMENT BUILDING OVER 1 LEVELS OF GARAGE AND ONE LEVEL OF COMMERCIAL IN A MIXED USED BUILDING. <<<VARIANCE FOR FIRE LIFE SAFETY SYSTEM  has been submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18758	17041-20000-24742	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.23162	-118.58832	ADDITION OF 1200 AMP SECTION WITH NO LOADS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18759	11041-20000-23827	3344 N BONNIE HILL DR	90068	4	159B177   614	2427001002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2011 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.1294	-118.3548	Plan check installation roof mounted 7.59KW Enphase Mircoinverter for single family dwelling. Variance to install M215 prior to Test Lab approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18760	10041-20000-03226	11640 BRUNELLO WAY		12	213B109   718	2701076083	[T]RE-1, [T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM	03/01/2010 12:00:00 AM		Permit Finaled	08/16/2010 12:00:00 AM	PIN	34.28332673	-118.5853738	"PROPOSE 33'-10""X22'-4"" GUARD STATION (321SF)/PORTE CORCHERE (287SF)  LOCATED ON PRIVATE STREET (BRUNNELLO WAY)Energy"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18761	10041-20000-19832	320 S LA BREA AVE	90036	4	135B181   238	5507008023	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.06822	-118.34383	PLAN CHECK T24 ENERGY FOR GENERAL/EMERGENCY LIGHTING FOR CHANGE OF USE FROM RETAIL TO RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18762	17041-10000-00815	100 N LOS ANGELES ST	90012	14	130-5A213  64	5161013905	PF-2D-CDO	Central	Central City	Historic Cultural		2074.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Issued	01/20/2017 12:00:00 AM	ADDRESS	34.05158	-118.24209	PC FOR POWER ONLY FOR A 911 UPS BYPASS UPGRADE. SCOPE INCLUDES ADDING TWO NEW 600A DISTRIBUTION BOARDS FOR A BYPASS SYSTEM. BYPASS WILL BE USED FOR UPS MAINTENANCE PURPOSES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18763	16041-10001-06629	3021 E ASBURY ST	90065	1	147A217    55	5454031024	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.09868	-118.22998	VOID(((PV1, ROOF MOUNTED SOLAR SYSTEM USING A INVERTER. (12) MODULES AND (1) INVERTER 3.8KW  TOTAL SIZE IS 3.8 KW.***SUBMITTAL PER APPLICANTS REQUEST.()))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18764	19041-10000-25857	10250 W SANTA MONICA BLVD 2720	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	energy pc only for T.I. to existing virtual reality entertaininment space in POD #4. area of scope is 827sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18765	11041-10000-26630	18421 S HOOVER ST	90248	15	063B201   146	6121020906	PF	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	33.86594	-118.28587	NEW INSTALLATION OF 336KW GROUND MOUNTED PHOTOVOLTAIC SYSTEM FOR LAUSD BUS GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18766	14041-20000-13721	17734 W MAYERLING ST	91344	12	216B129   443	2601040100	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.28479	-118.51972	PV1.  Install 7.8 kW roof-mounted utility-interactive PV system.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18767	19041-20000-50568	6014 N FAIR AVE	91606	2	177B173  1112	2337005024	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.17989	-118.37457	PV1. INSTALL 7.56 KW DC PV SYSTEM WITH (24) MODULES, (1) INVERTER(7.6TL) AND (2) TESLA ENERGY STORAGE BATTERIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18768	19041-20000-41165	3507 S ENVILLE PL	90016	10	120B173   446	5047002024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.02297	-118.37022	PV roof mounted system, System size: 6.48KW with 18 PV Modules and 18 mircoinverters, 1 sub-panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18769	15041-10000-16122	865 S FIGUEROA ST UNIT 2760	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.04653	-118.26275	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOE ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE PERFORMED IN SUITE 2760. TOTAL SQUARE FOOTAGE 4258	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18770	11041-10000-14450	524 S FLOWER ST	90071	9	130-5A209 231	5151025002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.05079	-118.2566	FIRE ALARM REPLACEMENT SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18771	12041-10000-12451	341 S VERMONT AVE	90020	4	135B197   392	5502008007	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.06776	-118.29188	Change to indoor and outdoor lighting to an existing McDonald's Restaurant.  New circuits. Occupancy load is 183 per applicant.  Full plan check is required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18772	18041-20000-12527	23226 W GONZALES DR	91367	3	171B093   431	2044024003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.16506	-118.63277	permit fees $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 18.6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18773	10041-10000-25221	2301 W BELLEVUE AVE 10th floor	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	34.07417	-118.26931	Upgrade fire alarm system on the 10th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18774	13041-20000-22680	1550 N WILCOX AVE	90028	13	148-5A187 338	5546013002	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.09947	-118.33087	EXISTING MIX USE. RENOVATION OF ENTIRE ELECTRICAL SYSTEM. NEW SERVICE. PC FOR POWER AND ENERGY. TOTAL AREA ABOUT 20K SQ FT.( FIRE ALARM VARIANCE HAS BEEN FILED). NON METHANE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18775	15041-20002-16513	5901 W CENTER DR PHASE 1	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			12/15/2017 12:00:00 AM			PC Approved	12/15/2017 12:00:00 AM	ADDRESS	33.97509	-118.38703	12.15.2017 - Plan check for modifications to approved set. Update unit-type designations to match architectural plan - update load calculations and SLD to reflect revised unit-type counts. Change EGC size on feeders for RSS1, RSS2, and RSS4 to #4/0. Changes clouded delta 8.======10/27/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 7. Scope of changes is rearrangement and resizing of feeders for apartment units. *****Previous Work Description*****pc for power and energy. new apartment building, 5 story, 95 units. total area 60280 sq ft(unconditioned ) + 4365 sq (conditioned). PHASE 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18776	19041-20000-27503	11837 N STONE GATE WAY	91326	12	217-5A115 135	2701025010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.28876	-118.56662	pv1install roof mounted pv system sized 5KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18777	18041-10001-06178	10530 W GARWOOD PL	90024	5	135B153   139	4360020012	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.06814	-118.43452	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDITION OF 2 NEW DISCONNECTS FOR ENERGY STORAGE SYSTEM PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL 5.8KVA) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL(200A). EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18778	14041-20000-24930	4570 N CHARMION LANE	91316	5	168B133   544	2290026022	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.15288	-118.51105	PV1Microinverter standard planInstall roof-mounted solar array on SFD, interconnect with MSP. System size: 9.6kW.(40) EnPhase M250 microinverters(40) SolarWorld Plus SW275 MONO	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18779	18041-10000-15409	6255 W SUNSET BLVD Suite 1450	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	Energy plan check for an existing office T.I located in the 14th floor of an high rise building. Scope includes new lighting and equipment, total area is 7990-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18780	17041-10000-05973	9318 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.23973	-118.53589	Plan check for title 24 only in existing space, replace existing Outdoor lighting fixtures with LED fixtures. Total area: 12,150 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18781	18041-10000-14441	11063 W PENDLETON ST Unit A-Bldg 1	91352	6	198B173    37	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.23911	-118.3725	PC FOR POWE AND ENERGY FOR EXISTING CORE/SHELL WAREHOUSE AND OFFICE SPACE. SCOPE INCLUDES NEW PANELS, NEW GENERATOR 25KW,CIRCUITS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 32356SQ.FT. B# = 18016-10000-12129	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18782	18041-20001-37703	5031 N BODA PL	91367	3	171B093   676	2047003011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.16259	-118.64159	10/11/2018 Changes to an approved set of plans. All changes have been clouded. The Enphase combiner box has been replaced with a load center. *****Previous Work Decription*****NEW ROOF MOUNTED 7.59 KW PV SYSTEM WITH 23 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18783	14041-10003-27847	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	8/12/2015CHANGES TO AN APPROVED SET OF PLANS.  RELOCATING AND ELIMINATING LOADS ON EXISTING GENERATOR.   ((8/12/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  TEMPORARY POWER FOR BAGGAGE HANDLING.))7/24/2015 PLAN CHECK FOR CHANGES TO SET OF PLANS DELTA 1 AND DELTA 2. RESHUFFLING OF LOADS AND RELOCATION OF PANELS. NO NEW LOADS HAVE BEEN ADDED. ((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX TERMINAL 1. CHANGING OF THE POWER DISTRIBUITION SYSTEM AND LIGHTING.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18784	17041-10000-18848	10250 W SANTA MONICA BLVD # 1060	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan Check TI on existing space and existing electrical service from Dist. Bard TSSB at Westfield Century City, 'LUSH'.  Ste. 1060, 2,528 sq.ft area.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18785	19041-10000-37159	940 S ALAMEDA ST	90021	14	121-5A215 167	5166026031	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Issued	12/11/2019 12:00:00 AM	ADDRESS	34.02623	-118.23898	PLAN CHECK FOR POWER ONLY - SCOPE INCLUDES INTERCONNECTION TO NEW SERVIVCE(19041-10000-37149) NOTED BELOW.  EQUIPMENT RATED AT 2500A 480/277V FEDING EXISTING EQIPMENT/PANEL   19041-10000-37149PLAN CHECK FOR POWER ONLY FOR FOR NEW 5000A SERVICE, WITH NEW DISTRIBUTION EQUIPMENT AND SUB-FEED TO EXISTING PANEL/EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18786	10041-10000-10168	440 S VETERAN AVE 1-24	90024	5	135B149   115	4363003***	[Q]R4-1VL	West Los Angeles	Westwood			2653.03	Electrical	Electrical	Apartment			05/28/2010 12:00:00 AM	05/28/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	34.06898	-118.45469	Replace fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18787	13041-20000-13798	515 S FLOWER ST 26THFLOOR-RM2616	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.05134	-118.25661	T24 FOR CONFERENCE ROOM ON THE 26TH FLOOR. CONFERENCE ROOM 2616.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18788	14041-10000-12437	127 S LA BREA AVE	90036	5	138B181   989	5513019011	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.07273	-118.34423	TI TO EXISTING RESTAURANT. PLAN CHECK IS FOR POWER AND ENERGY, OCCUPANT LOAD EXCEEDS 100. EXISTING SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18789	18041-20000-49191	6522 N WINNETKA AVE	91367	3	180B113   593	2134037007	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.18896	-118.57073	Plan check for PV roof mounted system, system size: 11.8kW DC, 10.0kW AC with 36 P V modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18790	18041-10000-10608	9038 N WOODMAN AVE	91331	6	195B153   113	2642031024	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.23409	-118.43928	Plan check for Title 24 only remove HID fixtures and replace with new LED fixtures outdoor lighing. Total area: 19,425 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18791	14041-10000-32419	1640 S SEPULVEDA BLVD 3rd Floor	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.04838	-118.44468	Title-24 plan check only for T.I. office(Thinkfactory Media) 21902 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18792	17041-20000-44612	20929 W VENTURA BLVD 1ST FLOOR-EAST BLDG	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR EAST BUILDING 1ST FLOOR BATHROOMS. 752 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18793	18041-10002-41438	545 S FIGUEROA ST 13TH FLOOR	90071	14	130-5A209 126	5151022001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.0514	-118.2582	DELTA 4 SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - PROVIDING T-24 OUTDOOR LIGHTING FORMS FOR THE 7 FIXTURES (LTG-07). ORIGINAL SCOPE<<<<<TITLE 24 ONLY FOR 544 SQFT ON THE 13TH FLOOR. SCOPE OF WORK INCLUDES LIGHTING FIXTURES AND EMERGENCY LIGHTING WITH 14 NUMBER OF LUMINAIRES IN TOTAL.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18794	16041-20000-45485	15233 W VENTURA BLVD #3	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.1538	-118.46502	TI/change of use from bank to dance studio.  Plan check for energy.   Building permit under 16016-20000-19476.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18795	14041-20000-09884	444 S FLOWER ST 10th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	<<SINCE PC ONLY WILL NOT ALLOW, INSPECTION XPRESS PERMIT TO BE ISSUED. THEREFORE  THE PLAN CHECK ONLY IS TAAKEN OFF,  BUT INDEED THIS PLAN IS JUST A PLAN CHECK ONLY. MEHDI>>FULL FLOOR T.I. INCLUDING NEW CEILING GRID NON-BEARING PARTITIONS AND FINISHES (17,338 S.F.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18796	17041-20001-02146	4001 W SUNSET BLVD	90029	13	145-5A201 293	5429010029	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.09271	-118.28035	Revisions to approved plans.  Additional panels to accommodate new service available fault current.  (((Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600-amps and tenant panels.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18797	14041-10000-16632	7326 N LAUREL CANYON BLVD	91605	2	186B165   550	2317015009	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.2039	-118.39608	Title-24 plan check only.  Total area = 1,080 sq. ft.Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18798	11041-10001-24575	1050 S FREDERICK ST BLDG #60	90291	11	111B145   881	4243003032	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	33.99927	-118.46029	Originally plan checked by MZ.  Service voltage has been modified, and several indoor lighting fixtures changed.   See delta-12 revisions.  Applicant did not submit a full new set, only modified pages.  ((Lincoln Place Apartment Building Project.  New Leasing Office, Bldg #60))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18799	19041-20000-47952	1025 S LA BREA AVE	90019	10	132B181   842	5084014027	C2-1	Central	Wilshire	P.I.C.O.		2162.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			Reviewed by Supervisor	01/15/2020 12:00:00 AM	ADDRESS	34.05621	-118.34528	FULL PLAN CHECK FOR POWER AND ENERGY. T24 PLAN CHECK. SCOPE OF WORK CONSISTS OF NEW 400A SERVICE, 400A PANEL, (3) 200A SUB PANEL AND TOTAL SQUARE FOOTAGE = 4768 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18800	19041-10000-46914	6677 W SANTA MONICA BLVD #101	90038	4	144B185   672	5532022027	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	02/20/2020 12:00:00 AM		Permit Finaled	03/03/2022 12:00:00 AM	ADDRESS	34.09085	-118.33573	FULL PC FOR A TI (FIRST TIME) SCOPE OF WORK IS INSTALLING TWO NEW PANELS AND A NEW 75 KVA TRANSFORMER INTERCONNECTED TO AN EXISTING 5000A SERVICE (277/480 3P,4W) USING UNIT EQUIPMENT IN A LOW RISE BULDING WITHOUT AN EMERGENCY GENERATOR. TOTALAFFECTED AREA IS 2286 SFQT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18801	16041-20000-31888	12345 N ARAGON WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29506	-118.45477	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18802	10041-20000-11058	15206-15210 W PARTHENIA ST Bldg 1& 2	91343	7	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills			1175.20, 1175.30	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	ADDRESS	34.2281	-118.46381	Plan check power and energy for new medical office (15210 Building 2). Service supplying from existing 15206 Building 1.  Plan includes supplemental application for new service for Building 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18803	11041-10000-10994	1420-1426 W JAMES M WOOD BLVD	90015	1	129A205    23	5137005020	C2-1	Central	Westlake			2100.10	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM	05/27/2011 12:00:00 AM		Permit Finaled	08/19/2011 12:00:00 AM	PIN	34.04950988	-118.27098288	T.I title 24 and emergency lighting. 4 story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18804	13041-10000-25474	840 W WEST 34TH ST	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.02316	-118.28529	TITLE 24 PLAN CHECK ONLY. USC MUSIC BUILDING. 4 STORIES. WORK IS ON 1ST AND 4TH FLOOR. 885 SQFT. EMERGENCY LIGHTING.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18805	15041-20000-12141	8932 N WOODMAN AVE	91331	6	195B153   373	2640016027	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Expired	06/11/2018 12:00:00 AM	ADDRESS	34.23211	-118.43779	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVMENT FOR MEDICAL CLINIC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18806	10041-10003-02167	300 E WATER ST	90744	15	027B209   227	7440010***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2947.00	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	10/26/2011 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	33.76636	-118.25616	"CHANGES TO APPROVED SET OF PLANS: ADDING PREFABRICATED MODULAR BUILDINGS AND CKTS FOR LANDSCAPE LIGHTING TO PANEL LOC AND CKTS FOR LANDSCAPE LIGHTING TO PANEL FL AND RELOCATED THE STANDBY GENERATOR((((((((REVISED SINGLE LINE DIAGRAM- ADDING AN OPTIONAL STANDBY GENERATOR AND ATS  TO SUPPLY THE SWBD ""POL"" WHEN POWER FROM SWBD "" PR"" IS INTERRUPTED. ((((((((Plan check for power new electrical system.  Electrical system to power prefab. modular buildings and to floating dock."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18807	16041-10001-39315	6765 W SELMA AVE 1-38	90028	13	148-5A185 276	5547013017	C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Approved	09/20/2019 12:00:00 AM	ADDRESS	34.09981	-118.33796	DELTA 4 CHANGES TO APPROVED SET. CHANGING UNDERGROUND CONNECTION TO OVERHEAD CONNECTION FROM UTILITY TO SERVICE EQUIPMENT. REVISING FEEDERS TO UNITS, INSTALLING COMPRESSION SLEVES, CHANGING CIRCUIT BREAKER TO FUSES ON UNITS SWITCHBOARDS. SCOPE ALSO INCLUDES CHANGING FEEDERS FROM COPPER TO AL ON HOUSE PANELS. ALL CHANGES ARE MARKED UNDER DELTA 4.   NOTE: PC ONLY. PERMIT UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18808	18041-10000-19192	9041 N LAUREL CANYON BLVD	91352	6	195B165   118	2629032001	[T][Q]RD2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Closed	12/09/2020 12:00:00 AM	ADDRESS	34.23351	-118.40574	FIRE ALARM SYSTME ON NEW 4-STORY, 96 UNIT APARTMENT SENIOR LIVING CENTER. (1) FACP, (296) DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18809	18041-10000-19851	1999 S AVENUE OF THE STARS #910	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	T-24, PC FOR ENERGY ONLY. TI FOR TWO SUITES AND AN EXISTIG CORRIDOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS  3307 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18810	10041-20000-02558	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	11/19/2010 12:00:00 AM	ADDRESS	33.95466	-118.38556	Convering of existing bus maintainace for CNG vehicle repair. putting 3 hours rated wall between # 1 and # 2. provide rooftop exhaust fan and explosion proof motor. Adding new light fixtures and  gas detection system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18811	17041-20000-18040	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2017 12:00:00 AM			Reviewed by Supervisor	06/07/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	PLANS LOST - APPLICATION ABANDONED 9.27.2017=====Plan check for solar pv system, roof-mounted on SFD and detached garage.8.88kW ungrounded system.(37) EnPhase M250 microinverters.(37) 290W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18812	18041-10000-02657	700 N ALAMEDA ST	90012	14	132A215   180	5409023930	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	03/23/2023 12:00:00 AM	ADDRESS	34.05488	-118.23748	PC for power and energy for renovations project for Metropolitan water district building. Scope includes new lighting, new panels, receptalces and equipment including UPS in electrical rooms. Total area is 312870sqft. B# 15016-10000-22112. Note that previous parking lighting was approved under expired plan 15041-10000-32385.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18813	16041-30001-26312	6719 N MELVIN AVE	91335	3	180B117   174	2132005012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.1926	-118.55975	EXPEDITE PER APPLICANTPV1ADDITION TO AN EXISTING PV SYSTEM. ROOF MOUNTED 3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18814	19041-10001-44935	12746 W JEFFERSON BLVD	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM			PC Approved	11/10/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	Expedite per applicant request (((Plan check for a PV2 129KW AC / 160KW DC roofmounted system. Scope include 370-module, (2) inverter interconnecting throgh the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18815	14041-10000-20991	6245 N WHITSETT AVE	91606	2	177B165   176	2332017016	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.18442	-118.40542	install solar system. 8 modules. 148 sq. ft. 1.96kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18816	16041-20002-07601	625 N NORTH BROADWAY	90012	1	133-5A215 171	5408016001	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	PIN	34.05963177	-118.24010092	06/23/2017 Changes to approved set. plancheck only.  Miscellaneous load changes and  system revisions to match as-built design.  Delta-5 revisions only. changes are clouded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18817	18041-20000-33433	20705 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.2931	-118.5849	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18818	11041-20000-18162	3758 N CROWNRIDGE DR	91403	5	162B141   318	2280008015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2011 12:00:00 AM			Plans on Hold	09/22/2011 12:00:00 AM	ADDRESS	34.13877	-118.47416	PV SYSTEM SINGLE FAMILY 7.2 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18819	14041-20000-18186	393 N KENTER AVE	90049	11	135B141   464	4403005018	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.06589	-118.48435	PV1Install roof-mounted solar array on SFD. System size: 4.73kW(22) EnPhase M215 microinverters(22) Solar World SW250 Poly pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18820	16041-20000-04326	21800 W OXNARD ST Suite 220	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for Title 24 only. Project site is an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 2,640 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18821	13041-10000-08379	2910 W WAVERLY DR	90039	4	151-5A207  88	5434029007	RD1.5-1XL	Central	Hollywood	Silver Lake	YES	1882.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.10939	-118.26568	DUPLEX HOME. 1INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 7.84 kW. PV1 TOTAL OF 32 MODULES, 2 TRANSFORMERLESS INVERTERS, NON-STANDARD PLAN. ADDITON OF LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18822	10041-10000-15438	17220 W VENTURA BLVD	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1VL, C2-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	08/18/2010 12:00:00 AM	ADDRESS	34.16046	-118.50839	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18823	17041-20000-20414	19536 W WELLS DR	91356	3	171B117   397	2175011010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.1635	-118.55916	permit fee $2.23 with state senate bill no. 1222pv1install roof mounted pv system sized 12kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18824	19041-20002-16156	8500 N BALBOA BLVD #140	91325	12	192B133    33	2689019019	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.22485	-118.50045	Revisions to approved plans.  As-built revisions affecting SLD and panel schedule details.  Plan check for energy only. (((PLAN CHECK FOR T24 ONLY. OFFICE TENANT IMPROVEMENT OF (E) OFFICE SPACE WITH (E) MEZZANINE.  TOTAL AREA APPROX. 11,621 SQ.FT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18825	15041-10000-02092	811 W WILSHIRE BLVD 1420	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.04973	-118.2584	Energy plan check for an office T.I in a high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18826	17041-10000-11915	1346 W COURT ST	90026	1	135A209   177	5160011010	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			04/12/2017 12:00:00 AM			PC Info Complete	04/13/2018 12:00:00 AM	ADDRESS	34.06444	-118.25789	PC for power and energy for new 4 story with 2 subterrenean levels 43 unit apartment. PC for new 1600 A 120/208 V srvice in a methane zone. Building #16010-10000-04312.FA Variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18827	17041-20001-24368	1111 S CARMELINA AVE	90049	11	126B141   218	4264019024	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.04315	-118.47204	Expedited plan check fee per applicant request.  PV1.  Install 8.7 kW DC roof mounted grid tied PV system.  (30) panels with (1) SolarEdge 7.6kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18828	17041-10000-23957	11979 W WALNUT LANE unit #3	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.03749	-118.4591	Install new rooftop solar system, 2kW AC. (8) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18829	18041-10000-05886	7234 N WOODLEY AVE	91406	6	186B141   854	2206034029	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Issued	02/16/2018 12:00:00 AM	ADDRESS	34.20231	-118.48346	REPLACE  OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18830	10041-10000-09476	3600 W WILSHIRE BLVD #410	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	08/02/2010 12:00:00 AM	ADDRESS	34.06156	-118.30335	Ti in a medical office. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18831	16041-10002-15022	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	11/18/16PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED UNDER DELTA DCN-004 AND CLOUDED ON PLANS. CHANGES INCLUDE REMOVING LOADS ON PANELS, REMOVING PANELS, REMOVING LIGHTING FIXTURES ON FLOOR PLANS, AND REVISING TITLE 24 CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18832	17041-10000-35963	1288 W JEFFERSON BLVD	90007	8	120B197   674	5040019046	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.02534	-118.29422	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18833	15041-20000-11895	12457 W OSPREY LANE Unit 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.97937	-118.41024	Plan check for PV1 roof mounted  system 8 modules (SUNPOWER MODULES SPR-230NE-LK-D) and 1 inverter(SB3000TL -US-22)PV clearance shall be relavent to Unit #1 of address 12457 Osprey Lane	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18834	16041-10000-16555	105 S FAIRFAX AVE	90036	5	138B177   597	5511025032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM			PC Info Complete	06/29/2016 12:00:00 AM	ADDRESS	34.07398	-118.36162	NEW METHANE MITIGATION SYSTEM ON NEW MIXED USE:  45 UNIT APARTMENT BUILDING 3-STORY TYPE V A  OVER COMMERCIAL OF TYPE I CONSTRUCTION FULLY SPRINKLERED. R-2 24956 SF/S-2 19,523 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18835	19041-30000-12779	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	05/08/2020 12:00:00 AM		Issued	05/08/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	Reconnection of existing loads on 9th floor onto the existing on-site emergency generator.  New equipment includes (5) ATSs, (1) distribution board, (2) transformers, and replaced subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18836	17041-10001-20389	201 W WORLD WAY	90045	11	090B165    62	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Approved	07/21/2017 12:00:00 AM	PIN	33.9448278	-118.40237129	PLAN CHECK FOR T24 ONLY FOR CORE & SHELL FOR EXISTING BUILDING. TOTAL CONEECTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18837	16041-10000-39891	18355 W COLLINS ST	91356	3	174B125   122	2157003077	R3-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.17501	-118.53273	Remove HID fixtures and replace with new LED fixtures. Total sqft = 16700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18838	19041-10000-23792	4730 W HOLLYWOOD BLVD	90027	13	147B197   272	5543009025	(Q)C2-1, C2-1D, P-1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.10142	-118.29272	T-24 PLAN CHECK FOR TI TO A CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA 1161 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18839	12041-20000-17201	21820 W BURBANK BLVD 330	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM			PC Approved	07/27/2012 12:00:00 AM	ADDRESS	34.17228	-118.6032	T.I. to existing building on 3rd floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-90000-15325	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18840	13041-20000-21111	13727 W FOOTHILL BLVD	91342	7	225B157   824	2509015029	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.3093	-118.43233	Plan check for energy and emergency lighting. Low-rise commercial. Building permit is 13016-20000-12876. Rok N' Sushi	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18841	18041-20000-16725	11350 N GLENOAKS BLVD	91331	7	213B161   844	2533028002	RA-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.27695	-118.41486	Plan check for PV roof mounted system commercial space, system size: 43kWac with 126 modules and 3 inverters(14.4kW) connected to 800A existing switch gear.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18842	17041-20001-01908	18415 W ALGIERS ST	91326	12	213B125   595	2870012013	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.27694	-118.53543	02/06/2017 Changes to an approved set of plans. Module count has been reduced by (2), for a total of (38) modules. The rest of the system has remained the same.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (40) modules. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18843	17041-20000-12356	18701 W PARTHENIA ST #6	91324	12	195B121   342	2770018011	M1-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Issued	04/17/2017 12:00:00 AM	ADDRESS	34.22838	-118.54047	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 672 sq. ft.Note: Building permit has been issued under 17016-20000-07001	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18844	11041-10000-11871	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			Plans on Hold	06/17/2011 12:00:00 AM	ADDRESS	34.05855	-118.23671	T.I.  Remodel in an existing building in the basement for a data center.  The building is 4 stories high.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18845	18041-20000-31943	12211 W HARTSOOK ST	91607	2	171B165   650	2356016019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.16408	-118.39914	Plan check for PV roof mounted system standard plan is being use, 5.0kW with 15 modules and 1 inverter(5.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18846	14041-10000-24468	5212 N DAHLIA DR	90041	14	163-5A227 204	5669012001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.14214	-118.19965	PV1, INSTALL 9.945 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(39) MODULES: KYOCERA  KD255GX-LFB3(2) INVERTE(S): SOLAREDGE SE6000A-US-ZB-U & SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18847	18041-20000-43738	3397 N BARHAM BLVD	90068	4	159B181   187	5579007022	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	01/11/2023 12:00:00 AM	ADDRESS	34.1333	-118.34402	PV3.  Install 4.5 kW roof mounted grid tied PV system.  (15) modules with 5 kW rated string inverter.  System 2 of 2 - other system is a 4.2 kW roof mounted grid tied PV system interconnecting at a separate subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18848	13041-20000-13043	19770 W BAHAMA ST	91324	12	195B117    36	2782038016	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	05/20/2013 12:00:00 AM	ADDRESS	34.23326	-118.56419	Plan check for energy and emergency lighting. warehouse with offices inside.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18849	14041-10000-14513	1243 S WELLESLEY AVE 1-11	90025	11	126B145   494	4267036012	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM			Reviewed by Supervisor	06/13/2014 12:00:00 AM	ADDRESS	34.0418	-118.46837	PV1, INSTALL 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18850	12041-20000-01667	5520 N DONNA AVE	91356	3	174B121   531	2163021034	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2012 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.17127	-118.5482	Photovoltaic system on roof of a single family dwellling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18851	19041-20000-09797	10743 N MOUNTAIR AVE pv1	91042	7	207B197   673	2566014043	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.26403	-118.29373	pv1install roof mounted pv system sized 5KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18852	18041-10000-08932	9764 N NATICK AVE	91343	7	201B149   385	2650016004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Issued	07/10/2018 12:00:00 AM	ADDRESS	34.24767	-118.45286	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES EXISITING MODULES ( PERMITED UNDER 18041-90000-17005). WITH NEW LOAD CENTER AND NEW INVERTER. TOTAL SYSTEM SIZE  7.6KWAC / 4.2KWDC  DC COUPLED ESS SYSTEM IS INCLUDED IN THIS SUBMITTAL UNDER 10002.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18853	17041-10000-41404	12700 W VAN NUYS BLVD Bldg 21&22	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			11/15/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	PV2, install new solar system, 15.2 kW AC system on a commercial (apartment) building: Building 21 and Building 22 interconnect.(63) modules with (63) power optimizer, and (2) 7.6 kW inverters, (1) load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18854	11041-20000-24782	420 S GRAND AVE	90013	9	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	05/01/2012 12:00:00 AM	PIN	34.05085086	-118.2528414	T.I. On the 3rd and 17th floor.  AT&T offices.  Existing redundant system.  Adding new switchborads, panels, transformers.  Total new load added to the system exceeds 400 Amps.  Plan check is for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18855	14041-10000-14740	13361 N GLENOAKS BLVD	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM			Verifications in Progress	08/22/2014 12:00:00 AM	ADDRESS	34.3146	-118.45921	PC FOR POWER AND FIRE ALARM. 15 NEW TEMPORARY CLASSROOM + ONE OFFICE AND ONE RESTROOM. EXISTING SERVICE. PUC VALLEY CAMPUS.FIRE ALARM TO BE SEPARATED. ONE CONTRACTOR HAS TO PULL THE PERMIT FOR BOTH ELECTRICAL AND FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18856	12041-10000-03439	13480 W MAXELLA AVE	90292	11	105B153    77	4212004032	[T][Q]RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	33.98522	-118.44179	Plan check for upgrading FACP and additional devices added to an existing fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18857	14041-10000-16548	12746 W JEFFERSON BLVD Unit 3140	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Full plan check for power and lighting. Change of use from retail to restaurant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18858	19041-20000-32886	758 S ALVARADO ST	90057	1	132A203   235	5141019008	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	34.05497	-118.27758	Change of use from dance hall to restaurant.  Plan check for Title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18859	16041-10000-32421	420 E 3RD ST	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM			Corrections Issued	09/12/2016 12:00:00 AM	ADDRESS	34.04686	-118.24182	T-24, PC FOR ENERGY ONLY. CONVERT AN (E) RETAIL SPACE IN THE LOBBY INTO TAKE OUT COFFEE SHOP. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 396 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18860	17041-20001-15070	2949 1/2 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	ADDRESS	34.03799	-118.20329	expeditepv2install roof mounted pv system sized 1.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18861	15041-20000-23905	21030 W GRESHAM ST	91304	3	195B105   139	2779003050	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM			Reviewed by Supervisor	08/07/2015 12:00:00 AM	ADDRESS	34.23048	-118.59195	Plan check for a PV2 roof-mounted PV system. System size is 46.5 kWac and consists of (186) modules, (186) micro-inverters, and (4) load centers. System is being installed on two separate buildings on the same parcel but interconnect to the same MSP.void application. complete redesign as been submitted under separete application.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18862	17041-10000-34670	13731 W SATICOY ST	91402	6	186B157    69	2214019023	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.2097	-118.43212	PC FOR FA IN AN OFFICE SINGLE STORY (NON REQUIRED SYSTEM). TOTAL DEVICE COUNT 91 WITH SINGLE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18863	12041-10000-19704	19600 W LEMARSH ST	91324	12	204B117   337	2726010024	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.2553	-118.56098	New 11.04 kw rooftop mounted pv system for an existing sfr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18864	13041-10000-29387	1100 S SAN PEDRO ST D04	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.03515	-118.25194	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 540 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18865	12041-10000-29557	904 N KENTER WAY	90049	11	138B137   193	4494024008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.07521	-118.48915	PV1 5.772KW AC ROOF-MOUNT FRONIUS. 2 STORY. STANDARD PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18866	13041-20000-15332	18003 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.265	-118.52529	RENOVATION OF TENANT SPACE FOR NEW BEAUTY SALON. NEW LIGHTING FIXTURES. LOW ELECTRICAL LOAD. PC FOR T24 ENERGY ONLY. TOTAL AREA 1568 SQ FT.PERMIT ISSUED IN # OF UNITS TO EXISTING CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18867	16041-10000-17244	818 E NOWITA PL	90291	11	108B145   565	4241019034	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Expired	06/19/2018 12:00:00 AM	ADDRESS	33.99393	-118.46007	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE SIZE IS 3.0KWac.(12)MODULES-SOLARCITY STANDARD 265W(1)INVERTER-ABB#PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18868	19041-20000-22205	22135 W ROSCOE BLVD LOT #27	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 27.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18869	11041-10000-20425	1127 W WILSHIRE BLVD	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			09/26/2011 12:00:00 AM	09/27/2011 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.05287	-118.26415	Change to lighting in Main Lobby of an existing office building.  PLAN CHECK ONLY for Energy with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18870	15041-10000-38653	748 N TERRACE 49	90042	1	151-5A223  29	5471015028	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.11138	-118.20993	PV1, ROOF MOUNTED SOLAR SYSTEM. (11) MODULES AND (I) INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18871	17041-10000-12659	7435 N GREENBUSH AVE	91605	2	186B157   297	2328027054	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.20563	-118.42635	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 30,050 SQFT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18872	19041-20000-41731	2049 S CENTURY PARK EAST 17th-Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	T.I. RENOVATION OF 17th floor PUBLIC REST ROOMS P.C FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18873	13041-10000-06557	6080 W 82ND ST	90045	11	099B169  1258	4107008023	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	33.96387	-118.39174	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7 KW. USING 30 PANELS. STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18874	15041-10000-23978	10250 W SANTA MONICA BLVD 1265	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	PIN	34.0586034	-118.41904766	TI TO AN EXISITNG SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 1265.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18875	16041-20000-06325	1316 N WESTERN AVE	90027	13	147A193   240	5544031018	C2-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.09543	-118.30905	Plan check for energy only. TI to existing office building. New lighting (incl. emergency) and receptacles. 2,782sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18876	19041-20001-37226	22540 W JEFFREY MARK CT #2	91311	12	204B097    15	2724004***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM			PC Approved	11/06/2019 12:00:00 AM	ADDRESS	34.2564	-118.61793	11-06-2019 Changes to an approved set of plan, changes include PV Module manufacture to LG 370W1C-V5 and revise plan to show inverter with EV Charger. Plan check onlyFees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18877	14041-20000-12476	11765 N RICASOLI WAY	91326	12	216B109    79	2701077023	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.28657	-118.58478	PV1Install roof-mounted solar array on SFD. Microinverter standard plan. Systen size: 7.65kW DC(30) Enphase M215-60-2LL-S22-IG microinverters(30) SolarWorld SW255 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18878	16041-10000-16045	203 E 111TH PL	90061	8	087A205    35	6073018015	R2-1	South Los Angeles	Southeast Los Angeles			2411.10	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	33.93404	-118.27141	PV1 roof mounted solar system installation to a single family home. (1) Central inverter rated at 5.0 Kw. (22) solar modules. Main breaker is being derated to 150 amps, under extra circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18879	17041-10002-01309	1331 N CAHUENGA BLVD	90028	13	147A187   323	5546017014	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM			PC Approved	03/16/2019 12:00:00 AM	ADDRESS	34.09556	-118.32924	note engineer was changedscope of work includes changing feeder length for majority of the unit panels changes under delta 22Aonly[PC for power and energy.  New 7 story mixed use apartment building with 3 levels of basement.  5 levels of apartment buildings over 2 levels of commercial.  369 apartment units, 28 transient (vacation rental) units, and 13 live work units.  New 4,000A service.  Total area = 313,900 sq. ft. Building permit #16010-10000-03279]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18880	17041-20001-28818	9516 N BADEN AVE	91311	12	201B097   183	2727001031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.24329	-118.61894	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.12.72kW ungrounded system.(53) EnPhase M250 microinverters.(53) 290W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18881	19041-20000-09103	451 E SHERMAN CL	90291	11	106-5A147 414	4227012016	RW1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Issued	03/22/2019 12:00:00 AM	ADDRESS	33.98431	-118.46416	PLAN CHECK FOR NEW 9KW DC/ 8KW AC ROOFTOP PV SYSTEM ON EXISTING 3 STORY SFD. SCOPE OF WORK INCLUDES (25) SUN POWER SPR-X22-360-D-AC PV MODULES WITH INTEGRATED 320W MICROINVERTERS, AND (1) NEW 125A PV LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18882	15041-10000-32218	11265 N ESKO AVE	91342	7	210B181    50	2550020023	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.2746	-118.34765	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11KW INTERCONNECTED WITH MSP.(38) SUNPOWER SPR327NE-WHT MODULES(2) POWERONE PVI-6000/5000 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18883	14041-20001-13355	6500 W WILSHIRE BLVD Suite 1860	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.06371	-118.3703	No fee (department error)....Change of address to reflect proper suite number....PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. OFFICES. NOT A PATIENT CARE ACCORDING TO APPLICANT. 2776 SQFT, EMERGENCY LIGHTING. 18TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18884	18041-10001-42490	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			Corrections Issued	06/04/2019 12:00:00 AM	ADDRESS	34.02201	-118.28947	"DETA ""1"" CHANGES TO THE APPROVED PLANS FOR CHANGING THE LOCTION OF BATTERY STORAGE SYSTEM IN THE BASEMENT.<<<PC FOR ADDITION OF UPS AND POWER CONDITIONER TO BASEMENT OF USC BUILDING. CONNECTING TO EXISTING 3000A SERVICE AND A 4000A GENERATOR TO PROVIDE EMERGENCY POWER. SCOPE INCLUDES ADDING A 1000KVA UPS TO EXISTING DISTRIBUTION SYSTEM WITH ASSOCIATED EQUIPMENT - SEE SHEET E-600 FOR SINGLE LINE CHANGES - COPY OF EXISTING APPORVED SET OF PLANS HAVE BEEN ATTACHED>>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18885	19041-10000-07896	6108 N CEDROS AVE	91411	6	177A149    53	2241022028	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.18101	-118.45294	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18886	19041-20000-41816	5922 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Hermon		1837.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.10512	-118.18416	TI for coin laundromat.  Permit is for lighting circuits only.  Other permit fees collected under 19041-20000-31003.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18887	18041-10000-47218	1433 W PACIFIC COAST HWY	90710	15	033B193    35	7410009038	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.78962	-118.30233	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18888	13041-10000-35514	413 W 104TH ST	90003	8	090A201    41	6061029015	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	33.94201	-118.28095	PV1, Install 4.25 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (17) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18889	15041-10000-43817	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	09/27/2016 12:00:00 AM		Issued	09/27/2016 12:00:00 AM	ADDRESS	33.94955	-118.38214	FULL PC FOR POWER AND ENERGY TO THE NEUTROGENA CAMPUS WIP ROOM. SCOPE OF WORK INCLUDES A NEW 1600 AMP DISTRIBUTION BOARD WITH 3 NEW CONDENSING UNITS. TOTAL SQ. FT. 4129.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18890	18041-20000-35856	6826 N VANTAGE AVE	91605	2	183B165   571	2321026026	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.19484	-118.39751	Plan check for a PV1 roof-mounted PV system. System size is 7.54 kWdc/7.6 kWac and consists of (1) inverter and (26) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18891	14041-10000-12124	335 W 7TH ST	90731	15	015B201   199	7455011028	CM-2-CDO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	33.7377	-118.28444	permit to be pulled at EPC counter only. Plan check for energy only. 1 story and emergency lights installed. Less than 400A per applicant.  INT T.I. & STOREFRONT REMODEL - CHANGE OF USE FROM RETAIL TO RESTAURANT (1,929SF), NEW RESTROOMS AND SOFFIT CONSTRUCTION PER PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18892	13041-20001-35348	4912 N PLACIDIA AVE	91601	4	168B177   221	2420011014	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.15989	-118.35593	((EXPEDITE FEES))PV1 TRANFORMERLESS SYSTEM. USING COMBINER BOX. 36 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18893	17041-10001-18404	19862 W VINTAGE ST	91311	12	204B113   725	2726005001	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.25166	-118.56633	Expedite fees only.       Installation of new roof mounted solar PV system on existing single family dwelling.  AC module system.  Total system size = 10.8 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18894	16041-20001-28164	22951 W ROSCOE BLVD	91304	12	192B097   589	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	09/06/2017 12:00:00 AM	PIN	34.22262962	-118.62405906	changes to an approved set of plans. plancheck only. changes noted delta 3.  changes include new UPS and relocation of panels and redistribution of loads. plan check for power only.   (((Plan check for power and energy. Project site is a new warehouse. Work includes a new 3000-amp service, associated distribution boards and load, and a total lighting area of 42,645 sq. ft.)))Note: Building application has been filed under 16010-10000-00122	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18895	15041-10000-23419	906 W MIRAFLORES AVE	90731	15	021B197   485	7447001020	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	33.75296	-118.29702	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.79KW. 2 INVERTERS AND 25 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18896	19041-20000-07274	2072 N MOUNT OLYMPUS DR	90046	4	150B177    87	5569012029	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/13/2019 12:00:00 AM	ADDRESS	34.10959	-118.36601	Plan check for PV roof mounted system, system size: 12.06KW DC, 10.86KW AC CEC with 36 PV Modules and 36 microinverters, IQ Combiner Box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18897	17041-10000-40157	8045 N WOODLEY AVE	91406	6	189B141    36	2205029047	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.21701	-118.48387	REPLACE OUTDOOR LUMINAIRES WITH LED TYPESPLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18898	17041-10000-12339	1555 W SUNSET BLVD #B	90026	13	139-5A209 170	5419028004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.07667	-118.25669	Plan check for power and Title 24.  T.I. for first time tenant.  New 932 sq. ft. restaraunt cafe.     Building permit #17016-10000-07771	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18899	17041-20000-11910	163 S ROCKINGHAM AVE	90049	11	132B137   528	4406016008	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.05525	-118.49283	new sfd 800 amp service.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18900	12041-10000-22847	4757 N COLLIS AVE	90032	14	148-5A233  61	5301025024	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	2011.10, 2013.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.10119	-118.17848	ROOF-MOUNTED 5.28KW PHOTOVOLTAIC SYSTEM USING MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18901	15041-10000-27393	13610 W EMELITA ST	91401	2	174B157   123	2343004005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Expired	09/14/2017 12:00:00 AM	ADDRESS	34.1765	-118.4291	New solar system with (11) modules: trina solar TSM-255 pd05.05, (1) INVERTER: PVI-3.0-OUTD-S-US-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18902	17041-10001-28208	22944 W COLLINS ST	91367	3	174B097   389	2041014031	RE9-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	ADDRESS	34.17348	-118.62707	EXPEDITE PER APPLICANT REQUEST. (((((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS           14.4KWac.(45)AC MODULES- SPR-X22-360-C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18903	15041-20001-33304	11932 N RICASOLI WAY LOT 6	91326	12	216B109   121	2701078***	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.28965	-118.58466	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN/ TOTAL OF 24 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18904	17041-20000-03496	5555 N BONNER AVE	91601	2	174B173  1075	2350005006	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.17159	-118.37432	INSTALLATION OF A NEW FIREALARM SYSTEM FOR  a new 4-story, 31-unit apartment building. 1 FACP , 2RPS AND 116 UNITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18905	19041-20000-07694	1620 N MICHELTORENA ST	90026	13	144A205    78	5425001024	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Closed	07/18/2020 12:00:00 AM	ADDRESS	34.09049	-118.27377	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM 9KW DC/7.25KW AC FOR EXISTING SFD. SCOPE OF WORK INCLUDES 1 NEW ENPHASE IQ COMBINER 3 BOX, (25) LG ELECTRONICS LG360Q1C-A5 PV MODULES, AND (25) ENPHASE IQ7PLUS-72-2-US MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18906	15041-20000-13386	3674 S RUTHELEN ST	90018	8	120B193  1630	5042017024	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.02115	-118.31269	PV1. Install roof mounted PV system sized 3.4 kW. Interconnected with main service panel.(16) Hyundai Solar M255 modules(16) Enphase M215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18907	18041-10000-10648	110 E 9TH ST 10TH FL.	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.04107	-118.25479	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES ADDING NEW LIGHTS FOR A NEW INTERCONNECTING STAIR ( NON-EGRESS) TO CONNECT TO 9TH FLOOR & 10TH FLOOR. TOTAL AFFECTED AREA IS 652 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18908	18041-20000-37692	6244 N RANCHITO AVE	91401	2	177B153   228	2239008005	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.18445	-118.43548	Plan check for PV roof mounted system, system size: 18.72KW DC, 14.976KW AC with 52 PV Modules and 2 inverters(7.6kW and 10.0kW) connected to 400A service	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18909	13041-20002-35142	4960 N PALO DR	91356	3	168B117    91	2175006036	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM			PC Approved	12/21/2013 12:00:00 AM	ADDRESS	34.15957	-118.55497	Change 7.5kW Sunpower inverter to a 7.5kW Fronius inverter.Change Sunpower SPR-327NE-WHT-D pv modules to Sunpower E20-327 pv modules.Module and inverter counts are the same. Electrical properties of swapped equipment is the same.[[[PV1 CENTRAL INVERTER. 5 STRINGS FOR 1 INVERTER]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18910	15041-20002-37038	17101 W BARNESTON ST	91344	12	216B133   527	2606018019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.28575	-118.50492	PV1. INSTALL 9.16 KW DC/8.8 KW AC PV SYSTEM WITH (28) MODULES, OPTIMIZERS AND (2) INVERTERS (3.800 KW) (5KW)INSPECTION FEE UNDER ONLINE PERMIT 15041-90000-37038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18911	14041-20000-02672	1121 W ALPINE ST	90012	1	136-5A211 351	5406021020	R3-1	Central	Central City North	Historic Cultural		1977.00	Electrical	Electrical	Apartment			01/30/2014 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.06691	-118.24786	ROOF MOUNTED PV. SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 12 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18912	15041-10000-39037	325 W ADAMS BLVD	90007	9	121-5A205 132	5126018032	(T)(Q)C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Apartment			11/18/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.02712	-118.27319	PV2 ROOF MOUNTED 315.5 KWAC TRANSFORMERLESS 1000VDC 3P 480V INVERTER OUTPUT. 1200 MODULES AND 14 INVERTERS. ZERO FEE DUE TO 2012 SENATE BILL NO. 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18913	17041-10002-36540	6238 W 6TH ST	90048	5	135B177   394	5510026023	R2-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			Corrections Issued	01/13/2018 12:00:00 AM	ADDRESS	34.06514	-118.36465	PC for changes to approved set for addition of tesla energy storage, relocation of gateway to lineside connection and decrease load center from 200 to 125A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18914	18041-20000-10709	5405 N HERMITAGE AVE	91607	2	171B165    62	2347008021	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			03/23/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	34.169	-118.40053	Plan check for power and energy. Project site is a new 3-story, 11-unit apartment building with a basement parking garage. Work includes an 800-amp service and a total lighting area of 10,299 sq. ft.Note: Building application has been generated under 17010-20000-02797	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18915	14041-10000-11674	5531 W HOLLYWOOD BLVD	90028	13	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.10188	-118.31033	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT YOGA STUDIO. TOTAL SQRFT 3500	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18916	16041-10000-41986	1830 W SLAUSON AVE	90047	8	105B193  1872	6001001023	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.98779	-118.31204	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 115000 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18917	14041-10001-04277	2511 N DALY ST	90031	1	139-5A221 205	5204003020	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Issued	03/27/2014 12:00:00 AM	ADDRESS	34.07571	-118.21587	(((CHANGES MADE TO APPROVED SET OF PLANS. DID SOME CHANGES TO THE LIGHTIING PLAN.)))permit to be pulled at EPC counter. PC for energy only. Less than 400A per applicant - Inspector to verify. Meat room and electrical rooms have lighting changes.TI TO (E) RETAIL. CHANGE TO SMART & FINAL. 621 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18918	17041-30000-03999	801 S FIGUEROA ST 7th Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the elevator lobby on the 7th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 320 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18919	18041-20000-28072	13646 W OSBORNE ST	91331	6	198B157   555	2625026003	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.23862	-118.43052	PV1.  Install roof mounted grid tied PV system sized 9.6 kW AC interconnected with MSP.  Derating main breaker to 175A to accommodate PV system installation.  (42) Canadian Solar modules 295(42) Enphase IQ-6-60 microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18920	15041-20001-02921	11813 W VALERIO ST	91605	2	186B169   659	2317017010	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			01/30/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	34.20495	-118.39087	Expedited per customer request.PV2. Install roof mounted PV system sized 3.0 kW. Interconnected with main service panel.(10) Kyocera KU255 Modules(1) PVI 3.0 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18921	19041-10002-17378	18915 W SUPERIOR ST	91324	12	201B121   449	2762039016	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.2465	-118.54541	Change to an approved set by changing the model of integrated rooftile solar panels. and reducing the power system size by removing one of the inverter from the system.  System size revised to 12.04482 kW DC.  (((Permit fee is $0.00 due to AB1414.PV1. NEW SINGLEFAMILY ROOFTOP SOLAR SYSTEM WITH TESLA POWERWALL. SYSTEM CONSIST OF 3000 SQ.FT OF INTEGRATED ROOFTILE SOLAR PANELS, THREE CENTRAL INVERTERS ( DELTA SOLIVIA 5.2, 5.2, 3.8), AND TWO TESLA POWERWALL BATTERIES. SYSTEM SIZE IS 16.38KWdc AND 14.2KWac)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18922	11041-10000-15994	5138 N FIGUEROA ST	90042	1	150A227   145	5468005042	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Expired	08/26/2013 12:00:00 AM	ADDRESS	34.10602	-118.19965	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18923	12041-20000-00892	300 S GRAND AVE 34TH FL.	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM			PC Approved	01/18/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	34th floor office t.i.Energy, emergencyRequest for Modification to separate Fire Alarm system filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18924	17041-20000-11525	20940 W BURBANK BLVD	91367	3	174B109   379	2149016025	CO(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.17302	-118.58923	REPLACING EXISITNG FIRE PUMP WITH NEW  AT KAISER PERMENANTE MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18925	16041-10000-17968	1750 S NEW ENGLAND ST 1-5	90006	1	126B197   489	5056014026	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Expired	06/25/2018 12:00:00 AM	ADDRESS	34.0417	-118.28758	Installing roof mounted solar system to a unit apartment. (1) inverter rated at 3.0 kw. (8) Solar modules. (1) load center 125 A.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18926	17041-10001-10219	16887 W CALLE DE SARAH	90272	11	138B117    49	4431038004	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM			PC Approved	04/10/2017 12:00:00 AM	ADDRESS	34.07782	-118.55268	EXPEDITED RSES PLAN CHECK PER APPLICANT.<<<<PV INSTALLATION OF A NEW 12.600 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A RESIDENTIAL HOUSE(35)MICRO INVERTER: SPR-X22-360-C-AC>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18927	18041-20000-41732	9901 N LURLINE AVE BLDG 4	91311	12	201B109    59	2741002006	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Apartment			10/31/2018 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Closed	04/02/2020 12:00:00 AM	ADDRESS	34.25058	-118.58431	New meters, power, and lighting for converted dwelling units.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18928	11041-10000-07521	200 N SPRING ST 2ND FLR	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM			PC Approved	04/14/2011 12:00:00 AM	ADDRESS	34.05405	-118.24317	T.I.  NEW CAFE ON THE SECOND FLOOR OF A HIGH RISE BUILDING.  TITLE 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18929	19041-20001-43686	1633 S FAIRFAX AVE	90019	10	129B173  1334	5068020009	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.04657	-118.36797	12-20-2019 Changes to an approved set of plan, changes include removed Storage Energy System All changes has been clouded.  PV roof , PV System size: 6.27KW with 19 PV modules and 19 microinverters. Fess $0.00 due to California Senat bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18930	18041-10000-00992	11976 W VENTURA BLVD	91604	2	162B165   132	2369015016	(Q)C2-1VL-RIO, (Q)P-1VL-RIO, C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.14341	-118.39292	TI to an existing retail store, scope of work includes the retrofit of fixtures only. Scope will decrease power consumption.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18931	13041-10000-05235	8755 N PASO ROBLES AVE	91325	12	195B133   340	2690011008	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.2301	-118.50416	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE FOR 10.56 KW. USING 44 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18932	14041-20000-02831	14810 W ORO GRANDE ST	91342	7	219B149   203	2506033051	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Expired	02/25/2016 12:00:00 AM	ADDRESS	34.29963	-118.45458	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC USING SOLAR EDGE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18933	12041-10000-16654	4812 N SUNNYSLOPE AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15818	-118.42674	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #13	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18934	11041-10000-25357	401 S ANDERSON ST	90033	14	126A219    25	5171010005	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	05/08/2012 12:00:00 AM	PIN	34.04062024	-118.22578512	INSTALLATION OF 2 EA WALK-IN COOLERSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18935	18041-20000-08170	1367 N ALTA VISTA BLVD 1-12	90046	4	147B181   990	5548020039	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.09588	-118.34738	New fire alarm system for 12-unit apartment building.   (52) devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18936	12041-20001-22749	617-619 N LA BREA AVE	90036	5	141B181   781	5525016004	C4-1VL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.08241	-118.34424	MODIFICATION TO AN ALREADY APPROVED ENERGY ONLY PLAN CHECK.  THE CHANGES ARE AN INCREASE TO THE LIGHTING DUE TO THE REMOVAL OF A DIVIDING WALL AND REMOVAL OF THE TRACK LIGHTS.  ONLY CHANGES OCCURED FOR THE INTERIOR LIGHTING. PLAN CHECK IS FOR TITLE 24 ONLY AND EMERGENCY LIGHTING.  <<<<<Change to lighting and receptacles to an existing retail space.  Load is less than 200 amps.  Plan check only for Energy, No emergency lighting.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18937	18041-10000-02144	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Closed	07/24/2019 12:00:00 AM	ADDRESS	34.10222	-118.32701	PC FOR TEMP SERVICE (RELOCATION) DUE TO DWP  TRANSFORMER UPGRADE. SCOPE INCLUDES NEW 800A SERVICE TO RELOCATE EXISING SERVICE ON GROUND FLOOR.  PART OF B#17016-10000-08562	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18938	17041-10000-23479	3321 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	07/25/2022 12:00:00 AM	ADDRESS	34.0275	-118.3723	Plan check for power and Title 24.  New 953 unit mixed use apartment building.  Core and shell permit for the 7 story podium with 2 levels of underground parking.  There will also be a 30 story apartment tower as part of the building under separate permit.  New 2,000 amp 4,160 volt service.  Lighting area = 1,017,121 sq. ft. (indoor) + 94,385 sq. ft. (outdoor)       Electrical permit for tower #17041-10000-21151Building permit #16010-10000-04628	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18939	17041-20000-20144	14600 W SHERMAN WAY	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.20095	-118.45113	Plan check for energy only. New lighting in corridor and common area of medical office (suite 300). No work being done in patient areas. 4,255sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18940	18041-20001-16560	7600 N BALBOA BLVD #205	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Revisions to approved set.  SLD changed to reflect (N) panel with (N) feeder.  (((Plan check for first time tenant retail space new lighting and receptacle. Total area: 1,314 sq ft.B#18016-10000-13841)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18941	13041-10000-06246	380 WORLD WAY Space T42	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	pc for power and energy. first time tenant. PROPOSED 1,025 SQFT.  TENANT IMPROVEMENT  FOR RETAIL CONCESSION  SPACE (TUMI ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18942	10041-20000-14453	900 E 1ST ST 1-30	90012	9	129A217    83	5163005006	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Apartment			07/26/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	ADDRESS	34.04816	-118.2335	corridor lighting in apartment. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18943	13041-20000-09856	621 S WESTERN AVE 107 to 110	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM			PC Approved	04/18/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	First time tenant in space.  Full plan check.  (Plan check only, permit is on a separate applicaiton.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18944	17041-10000-30528	5755 W RODEO ROAD	90016	10	120B173   502	5047002059	R4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	34.02184	-118.37165	REPLACING EXISTING HID FIXTURESWITH NEW LED UNITS. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18945	17041-10000-36844	1335 S OLIVE ST	90015	14	124-5A207  14	5134025900	PF-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.03726	-118.26394	REPLACE OUTDOOR EXISTING FIXURE WITH NEW LED FIXURE - TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18946	13041-20000-31273	10526 W DUBNOFF WAY BLDG J	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.18656	-118.36106	PC FOR POWER. NEW 1600A SERVICE AND DISTRIBUTION. BUILDING J OF SERIESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18947	16041-20000-36743	447 S HEWITT ST	90013	14	127-5A215 356	5163022017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.04216	-118.23526	Plan check for power and lighting. Project site is an existing commercial building. Project scope is a change of use from office studio to restaurant/tenant improvement. Total lighting area = 5,348 sq. ft.Note: Building application has been generated under 16016-10000-05341	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18948	17041-10000-25096	12000 S MAIN ST	90061	15	084B205  1252	6086001021	C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2414.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	33.92341	-118.27368	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AREA IS 9400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18949	18041-10000-41653	3269 E CESAR E CHAVEZ AVE	90063	14	126A229    33	5178025024	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.04083	-118.19394	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18950	17041-10001-05132	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM			PC Info Complete	09/21/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1,2 AND 3. CHANGE TO FLOOR PLAN LAYOUT. UPDATED LIGHTING, T24 AND PANEL SCHEDULES. UPDATED SINGLE LINE TO PROPERLY SHOW DIMMER PANEL SUBFEEDSPC ONLY. PERMIT COVERED UNDER MASTER APP	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18951	18041-10000-30332	550 S HOPE ST 22ND FLR	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM			Corrections Issued	08/10/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	PC FOR TENANT IMPROVEMENT WORK ON 22ND FLOOR FOR RESTROOM, ELEVEVATOR LOBYY AND CORRIDOR T-24 ENERGY ONLY. TOTAL SQ.FT 1442 SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. B# 18016-10000-19509	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18952	19041-20000-26632	19118 W MARILLA ST	91324	12	201B121   408	2762006012	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.24716	-118.55032	PLAN CHECK FOR ADDITION TO EXISTING PV ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. NEW ADDITION SYSTEM SIZE IS 12.87 KW DC/11.79KW AC CEC. SCOPE OF WORK INCLUDES (39) PANASONIC PV MODULES WITH IQ7X MICROINVERTERS, (2) NEW 125A SUBPANEL, AND A NEW 200A PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18953	10041-20000-15800	14006 W RIVERSIDE DR #24	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check T-24 energy (general/emergency) lighting for change of use from retail to hair salon #24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18954	18041-10000-19771	1302 S LA BREA AVE	90019	10	129B181   842	5070001018	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM	04/02/2019 12:00:00 AM		Issued	04/02/2019 12:00:00 AM	ADDRESS	34.04983	-118.34395	NEW TWO  STORY RETAIL (SPROUTS) STORE BUILDING EXISTING SERVICE APPROVED UNDER CORE AND SHELL.PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18955	15041-10005-00405	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM			PC Approved	04/25/2016 12:00:00 AM	ADDRESS	34.03365	-118.24048	04/25/16Changes to an approved set of plans. All changes are made under delta 9. Changes include adding/relocating exit signs from the ground to 9th floors. NOTE: ORIGINAL PERMIT PULLED UNDER PCIS#15041-10000-00405((((NEW 10 TIER OPEN PARKING GARAGE STRUCTURE.  PARKING BUILDING TO SERVE EXISTING ADJACENT BUILDINGS ON THE SAME PROPERTY. (APPRX. 1,405,621 SF W/ 3884 PARKING STALLS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18956	12041-10000-05939	10250 W SANTA MONICA BLVD #1240	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to an existing retail space at a mall.  Relocating 2 panels and a 75kva transformer, lighting changes and additional circuits.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Loads have not been plan checked. Revision to 12041-10000-00267. (((( Emergency lighting locations have changed. Added new lighting fixtures )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18957	18041-10000-35872	9315 N OSO AVE	91311	12	198B113   123	2748022080	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.23964	-118.57556	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18958	13041-20000-20940	13407 W VAIL LANE PV1	91342	7	225B157   972	2512031004	(T)(Q)RD4-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	34.3119	-118.42491	INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 3.6KW. USING TOTAL OF 16 MODULES. PERMIT ALREADY ISSUED UNDER APPLICATION # 13041-20000-09318. THIS APPLICATION IS PLAN CHECK ONLY BECAUSE TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18959	11041-10000-02008	20801 W RINALDI ST	91311	12	210B109   548	2706007024	(T)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.00	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.27025	-118.58647	New fire alarm system for the athletics building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18960	15041-10000-33443	2260 W 27TH ST	90018	10	123B189   916	5052018009	RD2-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.03069	-118.31659	PV1, INSTALL NEW 2.385 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(9) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18961	13041-20000-29079	8350 N MARLA AVE PV1	91304	12	192B089    47	2005020012	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.22059	-118.64467	PV1 STANDARD PLAN. 40 MODULES, 1 INVERTER, 1 COMBINER BOX. PANELS DID NOT CHANGE ORIENTATION OR QUANTITY ZONING WAS APPROVED ON APPLICATION 13041-20000-16071.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18962	19041-10002-14289	100 E SUNSET AVE	90291	11	109-5A143 198	4286015900	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	02/26/2020 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.99395	-118.477	CHANGES TO APPROVED SET OF PLANS. ALL CHANGE ARE CLOUDED UNDER DELTA 2-7. ADDING BUG EYES, CHANGING OUT BREAKER SIZES FOR TRANSFORMERS,  AND ADDING SELF ILLUMINATED EXIT SIGNS. HEAT LAMP REVISION. NOTE: PERMIT UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18963	15041-10000-13037	10943 N QUILL AVE	91040	7	210B189   275	2551033014	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.26827	-118.31676	PV1, INSTALL 6.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME TIE WITH MAIN SERVICE PANEL.(24) MODULES: KYOCERA KU26006XPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18964	11041-10000-27309	1031 S GAFFEY ST	90731	15	015B197  1206	7454014021	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	33.73446	-118.29249	Plan check power and enrgy for new Taco Bell with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18965	13041-20000-27583	17309 W RAYEN ST	91325	12	195B133   185	2768018006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2013 12:00:00 AM			Reviewed by Supervisor	10/16/2013 12:00:00 AM	ADDRESS	34.23232	-118.51173	CONNECTION AHEAD OF MAIN TO BE APPROVED BY DWP.  New rooftop PV system for an existing single family residence.  System is Ungrounded and uses Power Optimizers.  PLAN CHECK ONLY.  (This is a change from a previously approved plan)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
18966	15041-10000-17615	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake			2088.01	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.06281	-118.2731	Plan check for power only. INSTALL NEW 125KVA GENERATOR TO TEMP POWER DISTRIBUTION TDB-1 AND RECONNECT EXISTING LOADS (none of which serve patient care areas). NEWLY CONNECTED LOAD < 400 AMPS PLAN CHECK REQUESTED BY APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18967	10041-20001-16154	5670 W WILSHIRE BLVD #640	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			PC Approved	11/30/2010 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check only. Changes to approved plans T24 calculation, lighting layout, and autoshut off.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18968	10041-20000-09684	6933 W HOLLYWOOD BLVD unit c	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM			PC Approved	05/21/2010 12:00:00 AM	ADDRESS	34.10171	-118.34135	plan check for power ( 45KVA transformer, new panel,  18 circuits , HP unit)  only.Energy was plan checked under 10041-20000-04971 and permit has been issued.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18969	19041-30000-09298	14006 W RIVERSIDE DR Suite 269	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only. Project site is an existing commercial retail space. Project scope is a tenant improvement. Total lighting area = 2,503 sq. ft.Note: Building application has been generated under 19016-40000-07212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18970	15041-20000-43658	6286 N PENFIELD AVE	91367	3	177B113   351	2153036018	RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	PIN	34.18501693	-118.56720495	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.415KWdc/4.75KWc.(19)MODULES-SOLARWORLD SW 285 MONO(19)INVERTERS-ENPHASE M250-60-2LL-NA/S23	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18971	15041-10000-40212	1800 S AVENUE OF THE STARS PK LEVEL-PHASE 1	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	T-24,  TI IN A PARKING LEVEL GARAGE. SCOPE INLCUDES NEW LIGHTING AND RECEPTACLES TO NEW STORAGE AND RESTROOM SPACES. TOTAL SQ. FT. 2545	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18972	15041-20001-11893	12446 W OSPREY LANE Unit 1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	33.97949	-118.41001	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (8) modules, and (1) inverter. Note: PV solar clearance shall apply to the three units under this PCAM number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18973	14041-10000-04286	12301 W WILSHIRE BLVD STE 430	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	PIN	34.04277409	-118.46969044	Tenant improvement for existing office space. New partitions, new suspended ceiling, non-structural demolition.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18974	17041-20000-19112	115 N LA BREA AVE	90036	5	138B181   780	5513002002	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Issued	08/25/2017 12:00:00 AM	ADDRESS	34.07405	-118.34423	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18975	18041-10000-44273	6060 W CENTER DR	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	33.97602	-118.39073	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL HIGHRISE SCOPE OF WORK INCLUDES 18628 SQFT AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18976	15041-10000-34419	937 E 35TH ST	90011	9	115-5A209  80	5114016003	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.01191	-118.25933	PV1, INSTALL NEW 2.12KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY.(8) MODOULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
18977	13041-10000-23355	1900 S AVENUE OF THE STARS SUITE 2460	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Info Complete	08/27/2013 12:00:00 AM	ADDRESS	34.05979	-118.41671	T24 plan check only for existing small office tenant space in commercial highrise building.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18978	15041-10000-11235	939 S BROADWAY	90015	14	127-5A209 278	5139003006	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			04/15/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.04157	-118.25708	Pc for power. Temporary poower for modifiction an apartment building, one 600A distribution board , two motors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18979	12041-20000-23602	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	Change to lighting in the restroom of an existing high-rise office building on the 17th floor.  Plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18980	14041-10001-09757	8658 N NAGLE AVE	91402	6	195B157  1178	2627027034	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	05/15/2014 12:00:00 AM	ADDRESS	34.22703	-118.42307	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18981	17041-10000-24482	433 S SPRING ST	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Closed	04/11/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	Plan check for medium voltage temp power. Scope includes relocation of 750KVA XFRM, 75KVA XFRM, one 1200A panel and addition of a 200 A panel.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
18982	17041-20000-01315	1500 S GRAND AVE suite 100	90015	14	124-5A207 129	5134021016	C2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.03627	-118.26576	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total quare footage 2626.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18983	13041-10000-13464	14048 N SADDLE RIDGE ROAD	91342	7	231B141    44	2582030008	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.32588	-118.48252	PV1.  6.048 kW DC solar array installation with 28 panels to be tied into 2-story house's existing main service panel.  {28 modules: REC 250 PE} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18984	17041-20002-43976	4834 N ARCOLA AVE	91601	4	168B177   382	2420014020	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.15868	-118.35484	03/29/2018 Changes to an approved set of plans. All changes have been clouded. Changes have been made to reflect field conditions. *****Previous Work Description*****pv1install roof mounted pv system sized 6.6kw with battery back up inteconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18985	19041-10000-52499	10390 W SANTA MONICA BLVD #210	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	34.05734	-118.42365	TENANT IMPROVEMENT TO EXISTING OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18986	19041-10000-03250	990 W 190TH ST 6th Floor	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.85813	-118.29505	Full PC for power and energy. Interior tenant improvement to (E) office suite to create accessory training room. Scope includes new lights and receptacles. A-Occupant load > 100. Total affected area is 3104.9 Sq. Ft. B#19016-40000-02546	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18987	16041-20000-33906	12925 N BRADLEY AVE	91342	7	222B145   472	2506003017	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM			Re-Activate Application	09/23/2016 12:00:00 AM	ADDRESS	34.30432	-118.45895	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING. 2795 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18988	13041-20001-03460	11632 N SPY GLASS DR	91326	12	213B117   103	2822024017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.28286	-118.55785	[CHANGES MADE TO APPROVED SET OF PLANS. 2 NEW INVERTERS.]pv1 new 10.14kw rooftop mounted PV system for a sfr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18989	12041-10000-16920	849 S BROADWAY	90014	14	127-5A209 313	5144017***	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM	09/04/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.04271	-118.256	FIRST TIME COMMERCIAL RETAIL TENANT ON THE FIRST FLOOR OF A MIXED USED HIGH RISE BUILDING.  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18990	14041-10001-15414	2652 S ORCHARD AVE	90007	9	123B197  1171	5055026025	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.03128	-118.28731	Expedited RSES plan check per applicant request.{{PV1, Install 2.04 KW DC roof-mounted solar array on a two-story house, interconnect with main service panel. Transformerless inverter. With optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18991	12041-10000-30561	1955 E WASHINGTON BLVD	90021	14	118-5A215   4	5167019045	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Closed	01/14/2015 12:00:00 AM	ADDRESS	34.01971	-118.23785	NEW CONDUIT FROM SUBPANEL TO PROPANE FUEL  DISPENSER FOR COMMISSARY. CALCULATE FEES FOR MOTOR LATER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18992	16041-10000-07377	777 S SANTA FE AVE CMU	90021	14	124-5A217 270	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.03354	-118.23024	Installation of new fire alarm system in Ford Factory.  This is for CMU	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18993	17041-10000-43467	801 S FIGUEROA ST # 900	90017	14	129A207   173	5144021035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only in existing high-rise building office T.I. Total area: 8,096 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18994	14041-20001-01429	4814 N HASEKIAN DR	91356	3	168B121   249	2176031005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.15704	-118.55074	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18995	17041-20000-18433	637 S HAUSER BLVD	90036	4	135B181   758	5508014007	[Q]R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			06/02/2017 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.06378	-118.35157	service upgrade to an existing apartment building 600 amp service.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18996	19041-10000-23980	200 WORLD WAY Starbucks	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Full plan check for a new starbucks in a LAX terminal. Scope of work includes new equipment, new panel boards and new lighitng. Total affected area is 1515 sqft. B# 19016-10000-18927	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
18997	19041-10001-49357	10516 N VARIEL AVE	91311	12	207B105   549	2706018038	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.2614	-118.59279	0$ FEES PER AB1414PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES REVISIONS TO SINGLE LINE, ALL CHANGES ARE CLOUDED UNDER DELTA A. NOTE ORGINAL PLAN WAS SUBMITTED ON E-PLANORIGNAL SCOPE OF WORK__________________________________________________________[E-PLAN]NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 6.03KW DC/ 7.6KW AC, INCLUDING 18 MODULES (LG3355N1C-V5), 18 POWER OPTIMIZERS (P370),  AND CENTRAL INVERTER (SE7600A).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18998	19041-10001-14651	429 N VISTA ST	90036	5	141B181  1394	5526032008	RD1.5-1-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.07904	-118.35234	CHANGES TO APPROVED SET.. INCLUDE SUBPANEL TO MATCH EXISTING CONDITIONS. ALL CHANGES ARE CLOUDED.  PV1. Plan check for a 11.056 KW AC / 12.2KW DC roofmounted system with (1) inverter, (40) modules, and optimizers interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
18999	19041-10000-34238	3379 N MANDEVILLE CANYON ROAD	90049	11	150B133   111	4491006010	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.10464	-118.50377	PLAN CHECK FOR ROOF MOUNTED 11.4 PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 43 MODULES USIGN P400 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19000	13041-10000-07668	19701 S VERMONT AVE	90502	15	057B197    41	7351034025	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	33.85153	-118.29072	New fire alarm system for sprinkler and hvac for a single story office/storage warehouse.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19001	15041-20001-23739	20460 W VIA CELLINI	91326	12	219B109   262	2701055012	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.29511	-118.58101	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (23) modules. Being submitted because MSP is 300 Amp-rated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19002	12041-10000-02979	2852 W SUNSET BLVD	90026	13	141A205    29	5426020009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM			PC Approved	02/08/2012 12:00:00 AM	ADDRESS	34.08259	-118.27323	Title 24 and exit sign . restaurant one story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19003	18041-10000-23320	555 W 5TH ST Unit #3100	90013	14	130-5A211 161	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR OFFICE TI FOR TITLE 24 ENERGY ONLY IN A HIGH RISE.SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 7088 SQ.FTB# 18016-10000-19380	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19004	12041-20000-02520	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	T.I. to a high rise building on 13th, 14th, 19th, 20th, and 24th floors.  Install general/emergency lighting in restrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19005	18041-10000-39589	865 S FIGUEROA ST	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM			Ready to Issue	08/11/2020 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLAN CHECK FOR LIGHTING ONLY, PROPOSED EXTERIOR SITE IMPROVEMENT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 8182.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19006	18041-10000-17678	13535 W VENTURA BLVD	91423	4	165B157   672	2360007038	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM			PC Info Complete	05/14/2018 12:00:00 AM	ADDRESS	34.14768	-118.42818	PLANCHECK FOR T24 ENERGY OUTDOOR ONLY. ADDITION OF NEW STRING LIGTING AND RELOCATION OF EXISTING LIGHTING  IN OUTDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19007	12041-10000-30238	5857 S CENTRAL AVE	90001	9	108B209  1518	6007003902	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	03/07/2014 12:00:00 AM		Issued	03/07/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	SHOP BUILDING (RETAIL) . PLAN CHECK FOR site lighting. (Title 24 requirements).  Also stubbing for future signage (outdoor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19008	16041-30000-28253	2029 S CENTURY PARK EAST #2000N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check Title 24 only in existing high-rise building T.I. in office space. Total area: 7,645 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19009	19041-10000-34000	1771 W BLAKE AVE BLDG 4	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/30/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	4 OF 11. BLDG 4POWER PLAN CHECK FOR 800A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDINGS AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19010	13041-10000-30917	11041 N SALT LAKE AVE	91326	12	210B121   525	2717002033	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.27021	-118.5444	PV1, Install 8 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US., power optimizer, 32 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19011	17041-10000-13426	8308 N DE SOTO AVE	91304	3	192B109   730	2780005023	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Winnetka		1132.34	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.2203	-118.58831	PC for energy only, Outdoor Tilte 24. Removing HID fixtures and replacing them with new LED ones. Area: 20,075 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19012	12041-10000-09457	1715 S ARMACOST AVE	90025	11	126B149  1057	4259013003	RD1.5-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			04/25/2012 12:00:00 AM			Reviewed by Supervisor	10/23/2012 12:00:00 AM	ADDRESS	34.03867	-118.45767	this is a 4 unit apartment bldg, common area, 2 story, power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19013	17041-20000-18843	333 S GRAND AVE LEVEL #4	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for power and energy. Full floor TI to fourth floor of existing high rise building office space. 20,698sqft,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19014	16041-10001-15988	5224 W LOS ENCANTOS WAY	90027	4	151-5A195  20	5588037007	RE11-1	Central	Hollywood	Los Feliz	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	34.11134	-118.30405	5/6/2016 EXPDITED FEES PER APPLICANT REQUEST.PV1 9.81KW ROOF MOUNTED SYSTEM . 30 AC MODULES (E20-327-C-AC) AND PV MONITOR CONNECTED WITH A LOAD CENTER (60A).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19015	11041-10000-22791	17619 W SHERMAN WAY	91406	12	183B129    35	2228004007	C2-1VL, R1P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.20135	-118.51714	CHANGE OF USE FROM HEALTH CLUB TO A MEDICAL OFFICE FOR PHYSICAL THERAPY AND TENANT IMPROVEMENT INCLUDING NON-BEARING PARTITIONS, SUSPENDED CEILINGS, FINISHES, FIXTURES, AND RELATED MILLWORKS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19016	17041-20000-04852	7306 S WESTERN AVE	90047	8	102B193  1606	6018001008	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Issued	05/31/2017 12:00:00 AM	ADDRESS	33.97344	-118.30877	TI to existing retail building (Family Dollar Store). New lighting (including emergency) and receptacles. 10,165sqft.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19017	16041-30000-23410	17554 W DEVONSHIRE ST	91325	3	204B129   166	2734013005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.25743	-118.51725	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19018	18041-20000-45336	405 S TOWNE AVE	90013	14	127-5A213 187	5147009019	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	05/29/2020 12:00:00 AM		Issued	05/29/2020 12:00:00 AM	ADDRESS	34.04428	-118.24106	Addition to (E) building for entertainment studio. 800A 240/120V 3ph-4w delta service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19019	15041-10000-22424	100 WORLD WAY UNIT 127	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	TI TO AN EXISTING SINGLE TENANT SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE IN SPACE 127.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19020	19041-20000-46903	22624 W WATERBURY ST	91364	3	165B097   370	2078006024	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.14872	-118.61871	Plan check for PV roof mounted system, PV system size: 13.79KW DC, 12.34KW AC with 42 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19021	15041-10000-37916	12105 W WATERFRONT DR	90094	11	105B161  1199	4211010048	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	33.98095	-118.40764	new 5 story building. this is fire alarm system for core and shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19022	18041-20000-29549	16921 W ESQUIRA PL	91436	5	168B133   528	2289031006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.15321	-118.50204	PV1.  Install 10.716 kW roof mounted grid tied PV system.  (40) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19023	17041-10000-45695	14941 W DEVONSHIRE ST	91345	7	204B149   210	2648001013	A2-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.25739	-118.45803	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19024	17041-10003-17275	1156 S VICTORIA AVE	90019	10	129B189   419	5082025021	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.05137	-118.32603	[[4/20/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 3 CHANGES. ADDING A DISCONNECT]]]]Supplemental to changes to approved set of plans - changes include increasing the of main breaker from 150A to 200A - sum of all branch breakers <200A for 200A main panelInstallation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  1 new Tesla AC Powerwall 5.8 kVA 13.0 kWH battery and 1 new Solicia 7.6 kWac TL inverter (32 modules).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19025	19041-10000-40920	3912 S GRAND AVE	90037	9	117A203   277	5122046028	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.01322	-118.28039	PC FOR POWER ONLY, SCOPE OF WORK IS INSTALLING A NEW 1000A 120/208V 3PHASE 4 WIRE SERVICE FEEDING AN EXISTING SIGN. THE SIGN PLANS ARE UNDER PLAN CHECK THE APPLICATION NUMBER IS 19041-10001-26933	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19026	13041-10000-20094	10700 W SANTA MONICA BLVD #215	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.05167	-118.432	Title 24 plan check for replaced lighting in Suite 215 in response to inspector's request under express permit 13041-10000-18665.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19027	15041-10000-02390	11845 W OLYMPIC BLVD suite 675W-& 695W	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	PIN	34.03325831	-118.45191172	Plan check for Title 24 only. Project scope is a TI to merge two suites into one. Total lighting area = 5,820 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19028	17041-10000-23855	14030 W MARGATE ST	91316	4	171B153   244	2247019010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	PIN	34.16727284	-118.43888378	NEW PV SYSTEM IN A SFD USING CENTRAL INVERTAL. (1)FRONIUS INVERTER 5KW, (15) MODULES TOTAL SYSTEM IS 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19029	15041-20000-04414	3848-3852 S CRENSHAW BLVD suite 201	90008	10	117B185   775	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.01604	-118.33474	TI TO AN EXISTING TWO STORY COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD =400AMPS.  PLAN CHECK FOR ENERGY AMD EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE PERFORMED IN THE SECOND FLOOR.  TOTAL SQUARE FOOTSGE 7389.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19030	12041-10000-30808	13013 N MESA VERDE WAY	91342	7	225B165    19	2580018***	RD6-1, T, Q	North Valley				1061.11	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	04/02/2013 12:00:00 AM	ADDRESS	34.30864	-118.40719	PV1 PLAN CHECK FOR PHOTOVOLTAIC SYSTEM INSTALLATION ROOF MOUNTED 6.37 KWDC 2 STORY DETACHED CONDO [INVERTER: POWER-ONE-PVI-6000-OUTD-US] TRANSFORMERLESS SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19031	12041-20000-16178	3555 W TEMPLE ST	90004	13	139-5A201 140	5501003034	[Q]C2-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.07687	-118.28637	Change of use from a liquor store to food store.  Replace existing service with a new 600A three phase delta service to supply new and existing loads.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19032	11041-20003-15300	8628 N VAN NUYS BLVD Suite #205	91402	7	195B149   735	2638001057	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.22682	-118.44957	Relocate the feeder from panel 2A to the 800 ampere distribution board, and install a new single phase subpanel.  Inspecter to verify not less than 3 feet work space inf ront of panel.  See original plan as approved on application number 11041-20000-15300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19033	19041-20000-37249	10860 W WICKS ST	91040	7	204B173   369	2542031002	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.25288	-118.36697	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 8.68 KW DC/ 7.6 KW AC. SCOPE OF WORK CONSISTS OF (28) PV MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19034	18041-20000-07707	5022 N WHITSETT AVE #1-9	91607	2	171B165  1016	2356023012	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			03/02/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	10/15/2021 12:00:00 AM	ADDRESS	34.1619	-118.40506	New 9-unit apartment building with 800A 240/120V 3ph-4w service.   Building permit under 17010-20000-01307	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19035	13041-10000-17781	2107 W CAMBRIDGE ST	90006	10	126B193   130	5074007013	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Apartment			07/05/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.04466	-118.30296	PV1 2.45kw XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [ 1INV: POWERONE PV-3.6-OUT-S-US-z] [ 10MOD: TRINA TSM-245PC05.18}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19036	15041-10001-43581	8005 W FOOTHILL BLVD	91040	7	204B193   130	2556026017	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM			PC Approved	04/25/2016 12:00:00 AM	ADDRESS	34.25982	-118.30729	CHANGES TO APPROVED SET OF PLAN. REVISED LIGHITNG PLAN AND UPDATED T24 DOCUMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19037	14041-10001-29953	11115 N LAUREL CANYON BLVD	91340	7	210B149   706	2613025053	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	12/17/2014 12:00:00 AM	ADDRESS	34.2721	-118.44668	Expedited under customer request.(((((Plan check for a PV2 system. System size is 446 kW. System consists of (2,000) 250W DC modules, and (14) inverters.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19038	18041-10000-19206	4700 W SUNSET BLVD	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.09788	-118.29194	TENANT IMPROVEMENT IN AN EXISTING RESTAURANT SPACE FOR STARBUCKS COFFEE. WORK TO INCLUDE: INSTALL A 45 KVA X-FORMER, PANELS, CIRCUITS AND LIGHTS. PLAN CHECK FOR T-24 ENERGY ONLY. (NO CHANGE OF USE).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19039	17041-20000-41502	737 S LONGWOOD AVE	90005	4	132B185    95	5507029007	RS-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.06091	-118.33708	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.080 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19040	14041-20000-34462	6452 N PENFIELD AVE	91367	3	180B113   706	2134039005	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.18806	-118.56884	PV1. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM SIZE: 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19041	15041-10000-25223	15237 W ROSCOE BLVD	91402	6	192B145   401	2654025152	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			08/05/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.2216	-118.46473	Electrical system repairs and modifications to (E) single-story building commercial tenant space.  Plan check for energy for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19042	18041-10001-07818	1487-1489 W SUNSET BLVD C;D;E;F;G;-H;I	90026	13	139-5A209 265	5406001017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	03/27/2021 12:00:00 AM	ADDRESS	34.07579	-118.25466	Change to approved set by updating the fault current, AIC bracing and modifying the single line and floor plan. All changes under delta-R4, R5, R6, and delta-3 only. This project is located in the same plan with other 2 projects ( 18041-10001-07828 and 07823).(((PC FOR CHANGE OF USE FROM OFFICE TO RESTAURANT. SCOPE INCLUDES NEW PANELS, RECEPTICAS AND LIGHTING. PROJECT ADDRESS 1487-1489)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19043	10041-20000-21455	13691 W VAUGHN ST	91340	7	213B157   825	2523003004	M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	12/14/2011 12:00:00 AM	ADDRESS	34.27657	-118.43239	PLAN CHECK POWER AND ENERGY FOR 600A SERVICE NEW OFFICE BUILDING IN METHANE ZONE. MODIFICATION TO SEPERATE FIRE ALARM PLANS HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19044	15041-20000-22472	725 S FIGUEROA ST 33th floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only T.I. in existing office space in highrise building. Total indoor area: 3,900sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19045	12041-20000-09299	17636 W GLEDHILL ST	91325	12	198B129    74	2766001039	RA-1	North Valley				1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	PIN	34.24176691	-118.51906283	Roof mounted P.V. system with 11.77KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19046	17041-20002-41616	12700 W VAN NUYS BLVD bldg 19	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	Revision to approved set of plans.  Delta-4 revisions only.  Plans updated - 40A main circuit breaker added on (E) house panel. (((pv2install roof mounted pv system sized 3kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19047	19041-20000-28122	12430 N RALEIGH CT	91326	12	216B113   210	2701048009	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.2919	-118.57331	PLAN CHECK FOR NEW PV AND ESS FOR EXISTING SFD. SYSTEM SIZE IS 8.505 KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (27) HANWHA Q CELL PV MODULES WITH P320 OPTIMIZERS, A SE7600A INVERTER, A LG CHEM RESU10H BATTERY, A 100A SUB PANEL, AND A 5KVA  AUTO TRANSFORMER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19048	16041-20000-45652	10024 N HANNA AVE	91311	12	204B101   597	2745004025	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.25235	-118.60736	pv1install roof mounted pv system sized 5.8kw interconnected with msp.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19049	12041-10000-27729	3636 W BEVERLY BLVD	90004	13	138B197   449	5501009024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.07557	-118.28737	TI IN AN EXISTING 13 STORY TOWER. EXISTING SELF STORAGE AND OFFICE WITH A 700 SQ FT ADDITION.  UPGRADE LIGHTING AND PANELS. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19050	18041-20001-00030	17448 W RUSHING DR	91344	12	219B129   541	2608032009	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.2949	-118.51488	expeditepv1install roof mounted pv sysem sized 8.4kw interconnected with ,msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19051	13041-10000-23723	11870 W SANTA MONICA BLVD	90025	11	126B145   478	4263033055	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.0419	-118.45979	Title 24 for a fast food restaurant. emergency lighting. one story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19052	14041-10000-17441	6053 W CENTURY BLVD #1000	90045	11	093B169   305	4124030902	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.94648	-118.38998	PLANCHECK FOR TITLE 24 ENERGY. TENANT IMPROVEMENTS  AT THE 10TH FLOOR OF (E) OFFICE BUILDING. NEWLY CONNECTED LOAD < 400 AMPS. 6890 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19053	19041-10000-35891	928 N WESTERN AVE #928	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	33.75089	-118.30884	INSTALLING A 225KVA 240V:208V TRANSFORMER AND A 600AMP PANER FOR FUTURE TENANTS IN SUITE #928.  THERE ARE NO CONNECTED LOADS. ***COMPLETE PLAN CHECK WILL BE REQUIRED FOR TI***	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19054	15041-20000-35675	17235 W BARNESTON CT	91344	12	216B133   546	2606016015	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.28549	-118.51	PV system, using standard plan.Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (22) 270W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19055	14041-20001-17988	415 S BURLINGTON AVE 1-30	90057	1	133-5A205 194	5154023014	R4-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Apartment			07/02/2014 12:00:00 AM			PC Approved	07/25/2014 12:00:00 AM	ADDRESS	34.06012	-118.26997	Expedited plan check per applicant request.  PV1.  Install 12.8 kW DC roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19056	19041-20000-25600	506 N EVERGREEN AVE	90033	14	127-5A227  51	5178017001	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM			PC Info Complete	08/08/2019 12:00:00 AM	ADDRESS	34.04502	-118.19931	Remodel of existing hotel.  New 800 A, 240/120V 3ph-4w service.Note: Building application has been generated under 18016-30000-31350	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19057	13041-10000-34352	1653 E MAURETANIA ST	90744	15	036B213   551	7425025052	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	33.79047	-118.24279	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19058	15041-10000-36185	4830 N STROHM AVE	91601	4	168B177   392	2420005005	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.15858	-118.3592	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.(33) SOLAR WORLD SW280 MODULES(33) P300 OPTIMIZERS(1) SOLAREDGE SE10000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19059	14041-10000-23428	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.05373	-118.26606	Fire alrm system replacement , adding two new panels and 203 , total work 115720 sqft. high rise 9 plus roof.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19060	19041-10000-19628	8129 W 3RD ST	90048	5	138B173   885	5511021031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.07239	-118.36672	T-24 PC FOR A TI OF A RETAIL STORE OUTDOOR CANOPY LIGHTING. INDOOR LIGHTINING PERMIT WAS PULLED UNDER 19041-10000-07269. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 722 SQ.FTB#: 19016-10000-03350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19061	15041-20000-16791	6316 N TOPANGA CANYON BLVD B 1170	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	TI to existing commerical building. First time tenant. Plan check for power and energy. Adding new lighting. Total sqft. 1494.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19062	17041-30000-40689	7001 WORLD WAY WEST Gate 130	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	33.94447	-118.41469	Install 2 @ 220KVA Generators and 2 @ 150HP motors in a non-classified area for sanatery system at Gate 130 of LAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19063	17041-20000-09226	12601 W PIERCE ST 1, 2, 12	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 1, 2, and 12).10kW AC / 12.04Kw DC ungrounded system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19064	17041-10000-45132	5820 S SPARROW CT	90094	11	102B161  1224	4211037137	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	04/07/2018 12:00:00 AM	ADDRESS	33.97446	-118.41808	PC FOR ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (200A). PV IS EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19065	18041-20000-13768	5246 N HERMITAGE AVE	91607	2	171B165   382	2347023003	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			04/16/2018 12:00:00 AM	10/26/2023 12:00:00 AM		Issued	10/26/2023 12:00:00 AM	ADDRESS	34.16616	-118.40019	Plan check for power and energy for a new 5-story, 9-unit apartment building over 1 level of basement parking garage. Work includes a 800-amp service and a total lighting area of  14,000 sq. ft.Note: Building application has been generated under 17010-20000-04772	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19066	16041-20000-04870	7066 N MIDDLESBURY RIDGE CIR	91307	12	183B089   215	2028042014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Expired	04/06/2018 12:00:00 AM	ADDRESS	34.19922	-118.6482	Plan check for a PV1 roof-mounted PV system. Addition of a 3 kWac system onto an existing 5 kWac for a total system size of 8 kWac. Addition consists of (1) inverter and (8) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19067	12041-20000-12242	14237 W VAN NUYS BLVD	91331	6	201B153   110	2647022016	[T]RD2-1	North Valley	Arleta - Pacoima	Arleta		1192.00	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.25072	-118.44367	t24 lighting plan check for commercial school.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19068	18041-20000-17274	15566 W RAYEN ST 1-31	91343	6	195B141   389	2654015017	(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	12/07/2020 12:00:00 AM	ADDRESS	34.23174	-118.47244	Plan check  for power and energy for new appartment building 31 units. Total area: 23,352 sq ft.Building application permit: 13010-30000-04246	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19069	17041-20001-40973	957 1/2 N HYPERION AVE	90029	13	144A201   168	5427008007	[Q]RD1.5-1D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM			PC Approved	02/08/2018 12:00:00 AM	PIN	34.08919116	-118.28158648	Expedited plan check fee. PV1.  Install 6.09 kW roof mounted grid tied PV system.  (21) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19070	13041-10000-09776	1531 S PALOMA ST	90021	9	121-5A211 124	5132025003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.02793	-118.25054	MAIN SWITCH GEAR ONLY. REPLACEMENT DUE TO VANDALISM. PC FOR POWER. RECONNECTION OF EXISTING PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19071	17041-10000-42380	2049 S CENTURY PARK EAST LEVEL D-CPT EXERCI	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Issued	11/30/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 FOR TI (RENOVATION TO EXERCISE FACILITY) ON LEVEL D, TOTAL AFFECTED AREA 12,530 SQ. FT., NEW CONNECTED LOAD < 200A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19072	11041-10000-05206	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM			PC Info Complete	05/31/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	T.I FOR OFFICE AND RECYCLING OPERATION.  POWER FOR TRASH COMPACTORS.  FULL PLAN CHECK. (LMU)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19073	14041-20003-07630	6900 N WINNETKA AVE	91306	3	183B113   690	2135030006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.19574	-118.57078	Change from previously approved plans.  Relocate PV equipment and main service panel.  No changes in PV module and inverter model numbers.  Note: Permit is under the original application.  Plan check is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19074	17041-10000-23958	11979 W WALNUT LANE unit #4	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.03749	-118.4591	Install new rooftop solar system, 2kW AC. (8) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19075	16041-10000-19863	1324 E MORNINGSIDE WAY	90291	11	114B149  1031	4244020032	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.00503	-118.45526	PV1 rooftop solar 4.2kW AC system.   (23) KU2656ZPA   (1) PVI-4.2-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19076	12041-10001-30786	"12746 W JEFFERSON BLVD ""2"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	change to approved set, changes include adding circuits, removing and adding lighting, and relocate some electrical devices.(((Plan check power and energy for Building 2. Four story office shell on top of common subterranean parking with Building 1, 3, and 4. Service supply from Building 1. Site located in methane zone. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19077	19041-10000-32280	9600 N IRONDALE AVE	91311	12	201B109   270	2748003090	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.24456	-118.58584	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19078	14041-20001-35774	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Closed	01/09/2017 12:00:00 AM	ADDRESS	34.06338	-118.20434	"((9/22/2016))New cooling tower addition ""cwp-3"" connected to an existing distribution board MSCPA.  Plan check for power only.Plan check for power and energy for HSC Cooling Tower relocation with existing service."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19079	13041-20000-30942	811 W WILSHIRE BLVD Suite 1460	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.04973	-118.2584	T24 FOR EXISTING HIGHRISE OFFICE. SCOPE OF WORK ON 1460 [14TH FLOOR]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19080	12041-10000-08843	21600 W OXNARD ST STE 330	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.179	-118.6002	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENTS FOR OFFICE SUITE  #330 IN HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19081	16041-10002-35551	4671-4681 E HUNTINGTON DR SOUTH	90032	14	142-5A231  87	5213013020	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.08562	-118.18389	Changes to approved plans. Reduced Lights. T-24 Energy Indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19082	17041-10000-04676	2333 W RIPPLE ST	90039	13	151-5A211 268	5437028900	PF-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.10692	-118.25279	Plan check for power only in existing facility upgrade to 1000A Service  to feed existing buildings and feed new trailer building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19083	15041-10000-13673	2049 S CENTURY PARK EAST 28TH FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	ALTERATIONS ON 28TH FLOOR OF AN OFFICE BUILDING- LIGHTING; CKTS; AND NEW PANEL BOARDPLAB CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19084	19041-20000-51556	4521 N CARPENTER AVE	91607	2	168B169  1023	2364006026	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	02/25/2020 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.1527	-118.39116	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 19.8 KW DC/18.9 KW AC. SCOPE OF WORK CONSISTS OF (60) PV MODULES WITH MICROINVERTERS, AND A LOAD CENTERFees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19085	10041-10000-07135	3470 S TROUSDALE PKWY	90089	8	120A201    75	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	08/26/2010 12:00:00 AM	ADDRESS	34.02202	-118.28393	T.I. for USC computer lap rooms B31, B32, B34, B34A, and B36.  Install general and emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19086	16041-30000-33758	2049 S CENTURY PARK EAST 25th Fl-Corridor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Issued	09/27/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing high-rise corridor 25th floor based on 2008 Title 24 code modification in place. Total area: 1,560  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19087	12041-10000-04801	3909 W SUNSET BLVD SPACE A	90029	13	145-5A203 371	5429013020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.09199	-118.27967	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT TO EXISTING BAR IN SPACE A. (OCCUPANCY TYPE A2) EXISTING SERVICE. NEW PANELS, EQUIPMENT, AND BRANCH CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19088	15041-10001-35073	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta 35 MINOR CHANGES -ALL CHANGES ARE CLOUDED AND IDENTIFIED ON THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19089	15041-10000-10619	125 W 4TH ST	90013	14	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.0488	-118.24807	CONVERSION OF AN EXISTING 10 STORY OFFICE/BUILDING TO 188 LIVE/WORK UNITS, MIXED USED WITH RETAIL AND RESTAURANTS AT THE LOWER LEVEL. TWO SERVICES, PC FOR POWER AND ENERGY. BUILDING SUBMITTAL DATE BEFORE JULY 1, 2014 - 2008 ENERGY STANDARDS APPLIES. TOTAL SQ.FT 63,152FIRE VARIANCE ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19090	12041-20000-16363	168 S GRANVILLE AVE	90049	11	135B145   776	4401002004	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.06211	-118.47087	New 10000 sf two story single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19091	16041-20000-14384	11649 N PRAGER AVE	91342	7	213B165   281	2531026034	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Expired	05/28/2018 12:00:00 AM	ADDRESS	34.28188	-118.39595	PV1.  Install 6.12 kW DC rooftop-mounted PV system.  Central inverter standard plan.  (24) modules with (1) 6.6 kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19092	12041-10000-18676	2206 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.03796	-118.44083	TENANT IMPROVEMENT TO EXISTING TAKE-OUT RESTAURANT.  Load is less than 400 Amps.  Change to lighting and receptacles.  PLAN CHECK ONLY for Energy, All emergency lighting is existing and Not a part of this plan check per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19093	13041-10002-23362	446-450 S MAIN ST	90013	14	129A211   140	5148009012	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM			PC Info Complete	09/26/2014 12:00:00 AM	ADDRESS	34.0471	-118.24791	Changes apply to approved set, including Title 24 and 2 cam locks (100 amps each). Service load calculation needs to be recalculated.DELTA 2 CHANGES TO APPROVED SET.(APPROVED SET SUBMITTED FOR REFERENCE.)ADDING TWO 75 KVA TRANSFORMERS AND 1 NEW PANEL WITH CIRCUITS.{{{Full plan check power and energy for renovation of theater. New service size 800A. Total new load 740A.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19094	19041-20000-21394	8985 W VENICE BLVD	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.02733	-118.39241	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a change of use from retail to medical office. Total lighting area = 2,102 sq. ft.Note: Building application has been generated under 19016-40000-16341	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19095	15041-20000-22585	7610 COURAGE WAY	91405	6	186B145  1163		(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20904908	-118.46419309	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19096	15041-10000-18755	8400 S LINCOLN BLVD	90045	11	096B157   278	4113014035	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	02/14/2016 12:00:00 AM	ADDRESS	33.96144	-118.42041	CHANGE OF USE RETAIL TOStarbucks Coffeee shop NEW 16' X 18' UNCOVERED OUTDOOR DINING PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19097	16041-10000-44717	1245 W WILSHIRE BLVD #785	90017	1	132A207   288	5143017041	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	Full PC to medical office TI withing existing medical building (non-ohspod). Total area: 1675.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19098	16041-20000-29085	20041 W DAMPA LANE	91306	3	192B113   737	2782011***	(T)(Q)RD4-1XL	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.22695	-118.57001	Plan check for energy only. New COMMUNIITY SWIMMING POOL RESTROOMS building. New indoor and outdoor lighting. 423sqft indoor. 297sqft outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19099	14041-20000-17685	12381 W OSBORNE ST	91331	7	207B165   230	2536015029	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.26101	-118.40283	New fire alarm for new apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19100	12041-20000-24700	201 N FIGUEROA ST 7th Floor-14th Floor	90012	9	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	11/07/2012 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for energy and emergency lighting. 7th and 14th floors. 842sqft. High-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19101	14041-10001-17846	7315 N FIGUEROA ST # 102	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.13628	-118.18852	(((8/18/2014 - Supp. app. for change of label on main switchboard to accuratly reflect field conditions.)))Master permit description: CHANGE OF USE AND T.I. FOR NEW RESTAURANT PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19102	19041-20000-07287	16633 W VENTURA BLVD	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for Title 24 only in existing space corridor Total area: 1467 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19103	15041-10000-18711	523 W 6TH ST SUITE1200	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Info Complete	06/24/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	PC FOR ENERGY. TI FOR AN EXISTING OFFICE. ADDING 3 LIGHT FIXTURES. TOTALAREA 181 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19104	13041-20001-29527	6611 N VALJEAN AVE	91406	6	180B137   263	2233031044	M1-1, P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.19064	-118.48601	(((EXPEDITE FEES)))PV2 COMMERCIAL INSTALLATION. TOTAL SYSTEM SIZE 33KW. 132 MODULES AND 3 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19105	15041-10000-24892	1164 S DACOTAH ST	90023	14	120A223    88	5190010900	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.02419	-118.21008	PLAN CHECK FOR POWER FOR REPLACEMENT OF GENERATOR IN HAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19106	18041-10001-36150	10101 S BROADWAY	90003	8	091-5A203 235	6053024019	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			Reviewed by Supervisor	10/02/2018 12:00:00 AM	ADDRESS	33.94445	-118.27854	expedited feePLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR BOTH ROOF/CARPORT MOUNTED PV SYSTEM - INSTALLATION OF NEW CARPORT WITH MOUNTED PHOTVOLTAIC MODULE ROOFING.63.3KVA {61.56KW(AC)}. CONSISTING OF 2 INVERTER (30KVA(SMA3000TL-US) & 33.3KVA (SOLAREDGE SE33.3KUS WITH POWER OPTIMIZERS (P730))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19107	13041-10000-06275	11351 N DRONFIELD AVE	91331	7	210B165     6	2532009009	A2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.27673	-118.4036	New fire alarm system for a new 2-story school building with basement level.  Greater than 200 devices.  Control panel and 283 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19108	17041-10000-31205	319 E 2ND ST	90012	14	129A213    10	5161017034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.04929	-118.24098	PC for T24 for replacment of outdoor existing fixtures withLED fixtures. Total area of 30200sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19109	10041-20000-25126	5410 N VINELAND AVE	91601	4	171B173    86	2416002031	(Q)MR2-2D	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Closed	02/23/2024 12:00:00 AM	ADDRESS	34.16898	-118.37008	Replace fire alarm panel and devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19110	19041-10000-48837	959 N EMBURY ST	90272	11	129B129   772	4423017025	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.04684	-118.52321	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR A SERVICE SIZE OF 200 AMPS. INSTALLATION INCLUDES 12 MODULES (HANWHA Q-CELLS 315 W), 1 CENTRAL INVERTER (SE3800H), 12 OPTIMIZERS (P400), 1 POWERWALL, AND 1 PANEL OF 200 AMPS.SYSTEM SIZE: 3.78 KW DC, 3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19111	16041-10000-34160	1420 W JAMES M. WOOD BLVD 2ND FLR	90015	1	129A205    23	5137005020	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.04957	-118.27087	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM LIBRARY TO OFFICE ON 2ND FLOOR AND TENANT IMPROVEMENT AT CASSASA BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE/CONFERENCE/CORRIDOR SPACES ON THE 2ND FLOOR OF A SCHOOL. TOTAL AFFECTED AREA IS 4318 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19112	11041-10000-15195	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I.  Existing reataurant. Adding 9 new light fixtures, 4 new fans and 4 new heaters.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19113	13041-20000-27224	12645 W BEATRICE ST	90066	11	105B161  1007	4211006011	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	ADDRESS	33.98004	-118.41736	New 1000 amp distribution board, new panels, circuits, reconnect loads and lighting to an existing 1-story office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19114	12041-10000-14484	9536 N LEMONA AVE	91343	7	201B149   765	2650004033	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.24371	-118.45864	Plan check for PV System. Single Family Dwelling. 11.22kW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19115	14041-20000-35887	4018 N ROCK HAMPTON DR	91356	3	165B125   451	2184053003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.14441	-118.53625	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.8KW.  SOLAR OPTOMIZERS.(1) SOLAREDGE SE5000(1) SOLAREDGE SE3800(41) HUYNDAI MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19116	17041-10002-04631	20105 W RINALDI ST BLDG S3	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.27543	-118.57209	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  14, & 25. CHANGES INCLUDE RELOCATING SITE/LANDSCAPE LIGHTING, ADDING LANDSCAPE LIGHTING, REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, REVISING PANEL SCHEDULES,  AND SPECIFYING EGC CONDUCTORS ON THE FLOOR PLANS.NOTE: PERMIT HAS BEEN PULLED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19117	18041-20000-04977	4008 S WOODLAWN AVE	90011	9	115-5A205 256	5113027004	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM			Verifications in Progress	04/11/2019 12:00:00 AM	ADDRESS	34.01082	-118.27269	Addition to an existing apartment building.  600A 240/120V 1ph-3w service upgrade with 3rd floor addition and six new units.  Building permit 17014-10000-05340.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19118	19041-10000-34592	1404 W 6TH ST	90017	1	132A205   165	5142028019	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.0559	-118.26781	"CHANGE TO AN APPROVED SET OF T-24 ONLY PLAN. CHANGE IS UNDER DELTA 1 . CHANGE INCLUDE REDUCING PANEL ""A"" FROM 125A TO 100A AND UPDATING THE CALCULATIONS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19119	19041-10000-21549	12200 W OLYMPIC BLVD 110	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Info Complete	06/06/2019 12:00:00 AM	ADDRESS	34.03195	-118.45506	NEW PC FOR T24  ENERGY ONLY FOR NEW OFFICE TI ( CORE ONLY). SCOPE INCLUDES LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 6427 SQ.FT . DESIGN CHANGE UNDER FROM 19041-10000-02197.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19120	18041-10000-47486	10926 N COZYCROFT AVE	91311	12	210B109   251	2707025011	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.26908	-118.58137	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 52 MODULES (LG330NIC-A5) AND 52 MICROINVERTERS (ENPHASE IQ7-PLUS-72-2-US). SYSTEM SIZE IS 17.16 KWdc and 15.34  KWac. SCOPE INCLUDES 125A  AC COMBINER BOXPERMIT FEE IS $ 0 IN ACCORDANCE WITH AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19121	11041-10000-07985	910 N MAHAR AVE	90744	15	033B213   833	7425039004	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	33.78274	-118.24603	Addition to an existing warehouse. New service, panel board 7 circuits. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19122	10041-20001-22782	1521 W PICO BLVD 1-56	90015	1	127-5A203 102	5137032023	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Apartment			02/17/2011 12:00:00 AM			PC Approved	02/17/2011 12:00:00 AM	ADDRESS	34.04432	-118.27583	PLAN CHECK ONLY FOR REVISION TO APPROVED PLANS. REVISION MARKED DELTA 1. FIRE ALARM APARTEMENT BUILDING 3 STORIES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19123	18041-10000-42888	2160 W ADAMS BLVD	90018	10	123B189   697	5052031021	R3-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.03248	-118.3142	FULL PLAN CHECK FOR POWER AND ENERGY FOR OFFICE SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING  DISTRIBUTION SYSTEM. TOTAL EFFECTED AREA 17840 SQFT NEW CONNECTED LOAD OVER 497.24 AMPSBLD# 18016-10000-34802BLD# 18016-10000-28799	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19124	09041-10001-02623	240 S WESTLAKE AVE	90057	13	135A205   188	5154003009	R3-1	Central	Westlake		YES	2084.00	Electrical	Electrical	Apartment			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/05/2010 12:00:00 AM	ADDRESS	34.0637	-118.27014	REVISIONS TO APPROVED SET OF PLANS-SEPARATING THE SWBD MSA FROM THE OTHER SWBDS AND RECONNECTING  USING FEEDERS/CONDUIT SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19125	16041-20000-03354	20151 W RUNNYMEDE ST	91306	3	186B113   405	2114006016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Expired	02/28/2018 12:00:00 AM	ADDRESS	34.20603	-118.57264	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 10KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19126	17041-10000-00551	719 E 25TH ST APT B	90011	9	120A209   250	5131023022	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Apartment			01/06/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.02228	-118.26008	PV2, INSTALL NEW 2.12 KW DC ROOF-MOUNTED SOLAR SYTEM ON A MULTI FAMILY HOUSE.(8)MODULES: AXITEC AXLPOWER AC-265P/156-60(1) INVERTER:FRONIUS GALVO 2.5-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19127	17041-20000-22514	5835 N SEPULVEDA BLVD	91411	4	174B145    67	2243001029	M1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.17657	-118.46647	PLANCHECK FOR T24 ENERGY. Tenant Improvement and Change of Use from (E)  Auto Repair to Office for Used Car Sales. 13229 SQFT INDOOR + OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19128	15041-20000-32364	15910 W VENTURA BLVD 18TH FLOOR	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.15561	-118.47969	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS. 18TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19129	19041-10000-03696	4561 W COLORADO BLVD	90039	13	162B201    17	5593012026	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.14325	-118.27364	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19130	18041-10000-08622	12448 W BRADDOCK DR	90066	11	108B157  1555	4221006058	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.98877	-118.41951	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19131	14041-20000-09541	4330 W SUNSET BLVD	90029	13	145-5A201  13	5429006003	C2-1	Central	Hollywood	Los Feliz		1913.02	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.09512	-118.28377	New 600A main switchboard for 3 retail tenant spaces in existing building.  TI to existing 1200 s.f. retail unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19132	17041-10000-29171	2830 S CENTRAL AVE	90011	9	117A209   110	5119014032	[Q]M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.01575	-118.25594	PC for T24 only for lighting and receptacles in TI for Dance studio. Installing new panel, lights and receptacles. Building# 11014-10000-01727. Total area of 2719 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19133	16041-20000-41174	8614 N VAN NUYS BLVD #C	91402	6	192B149    35	2638001039	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.2266	-118.44937	Ice cream shop TI.  Building permit filed under 16016-20000-06107.   Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19134	15041-20000-19176	12578 W CATHY ST	91342	7	228B161   669	2580005017	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.3196	-118.40746	PV1. Install roof mounted PV system sized 3.4 kW. Interconnected with main service panel.(16) Sunedison F270 Modules(16) M215 Enphase Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19135	11041-10000-00784	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM			Verifications in Progress	02/16/2011 12:00:00 AM	ADDRESS	33.77884	-118.29327	INSTALL A NEW 500HP, 4160V FIRE PUMP IN CONOCO PHILLIPS REFINARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19136	15041-10000-12028	200 WORLD WAY TERM 2-# 234	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	AT LAX, INSTALLATION OF ILLUMINATED SIGNS FOR TENANATPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19137	13041-20000-22851	4426 N COLBATH AVE	91423	4	165B153   244	2271011006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.15104	-118.43644	PV1 TRANSFORMERLESS SYSTEM 4.88 KWAC. 23 MODULES AND 1 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19138	13041-10001-30849	8444 N PINELAKE DR	91304	12	192B093   145	2005015004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/27/2013 12:00:00 AM	ADDRESS	34.22243	-118.63739	Expedited RSES plan check per applicant request.PV1, Install 9.25 kW DC roof-mounted solar array, interconnect with service panel. Multiple transformerless inverters: Solaredge SE 3800A-US and Solaredge SE 5000A-US. 37 modules: Yingli Yl245P-29b.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19139	16041-20000-37725	22517 W VENTURA BLVD	91364	3	171B101   119	2040025029	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.1681	-118.61742	remove existing hid fixtures and replace with new led outdoors.  plan check for energy 23800 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19140	14041-10000-30629	6707 W ST ESTABAN ST	91042	7	201A203   248	2564011036	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.24555	-118.27858	Plan check for a PV1 system. System size is 5 kW. System consists of (22) modules and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19141	16041-10000-17150	10807 W BELLAGIO ROAD	90077	5	138B149    26	4362006006	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Expired	06/18/2018 12:00:00 AM	ADDRESS	34.07832	-118.45299	"Add (18) modules to an (E) 18kW system. Existing system under permit# 15041-20000-11209.<<""0$ permit fees due to senate bill 1222""Installation of new roof mounted solar PV array.  Total system size = 18 kWac.  Two inverter system with 5 strings. >>"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19142	11041-10000-03572	340 S MAIN ST	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	33.99519	-118.47673	Tenant improvements to all three floor including new exterior and interior openings, new restrooms, caf� and kitchen, new offices, pantries, and conference rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19143	15041-10000-38792	2869 N GLENVIEW AVE	90039	13	150A211   119	5437030031	MR1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.10617	-118.25076	T-24, REMOVED HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 4432.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19144	16041-20000-45040	7816 S BERGER AVE	90293	11	099B153    46	4114002021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	33.96517	-118.43245	Plan check for power only. Upgrade service to 600A for SFD. Refeed existing distribtion. Replace gym panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19145	13041-10000-20289	1939 W CLINTON ST	90026	13	138A207    57	5404008014	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.07361	-118.26511	PV1 ROOF MOUNTED SOLAR INSTALLATION FOR A SFD. SYSTEM SIZE IS 4.25 KW DC / 3.72 KW AC. 17 MODULES IN TWO STRINGS. [MODULES: ALEO # S18U250 |||| INVETER: POWERONE # PVI-3.6-OUTD-US-240] PLANS SUBMITTED BEFORE IMPLEMENTATION OF RSES FEE SCHEDULE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19146	14041-20000-32115	6020 N BELLAIRE AVE	91606	2	177B161   811	2332021001	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.18007	-118.40928	PV1 INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN ELECTRIC PANEL. 8.4 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19147	17041-10001-17712	1601 N VINE ST 7TH FLR	90028	13	148-5A187 301	5546009154	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Info Complete	11/03/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	PC FOR REVISIONS TO APPROVED SET TO REFLECT FIELD CHANGES ON THE PLAN . SCOPE INCLUDES REVISION TO FIXTURE SHCHEDULE AND TITLE 24 FORMS. THIS IS PLAN CHECK ONLY!WORK 7TH FLOOR  FULL FLOOR  TOTAL AFFECTED AREA 13,397 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19148	17041-10002-35600	12822 W STRATHERN ST	91605	2	189B161   421	2305037046	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.21567	-118.41369	CHANGES TO APPROVED SET DUE TO FIELD INSTALLATION under delta 2. SCOPE INCLUDES ADDING ONE ADDITIONAL AC MODULE. THIS IS PLAN CHECK ONLY. PERMIT FEES PAID UNDER MASTER.  PC FOR ROOFMOUNTED PV ON SFD. SYSTEM SIZE 10.05KW, SCOPE INCLUDES 29 AC MODULES AND LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19149	17041-20000-09800	13384 N DRONFIELD AVE	91342	7	225B149   135	2504012006	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.31524	-118.44653	pv1install roof mounted pv system sized 10kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19150	14041-20000-15774	4066 W 7TH ST	90005	4	132B189   325	5092010007	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.05977	-118.31658	New roof mounted PV system with Enphase microinverter model M215-60-2LL.  Total system size is 4.1KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19151	18041-20000-35853	18400 W BESSEMER ST	91335	3	177B125   644	2124013006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.18094	-118.53364	Plan check for a PV1 roof-mounted PV system. System size is 5.22 kWdc/5 kWac and consists of (1) inverter and (18) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19152	15041-20000-03418	12130 W MILLENNIUM 1ST FLR	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.98008	-118.40646	TI TO AN EXISTING COMMERCIAL HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHTING, NEW CONTROLS AND NEW PANELS.  NEWLY CONNECTED  LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4043.  SCOPE OF WORK TO BE PERFORMED IN THE 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19153	18041-20001-34477	3720 N LITCHFIELD LANE	91356	3	162B117   401	2177043011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM			PC Approved	09/15/2018 12:00:00 AM	ADDRESS	34.13655	-118.55193	Expedited plan check fee per applicant request. PV1.  Install 21.45 kW roof mounted grid tied PV system.  (66) modules with (2) 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19154	19041-10001-50114	2328 N BRONSON HILL DR	90068	4	153A191   378	5587028002	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	34.11262	-118.31556	EXPEDITE PER APPLICANT REQUEST. NEW PV-1 SOLAR SYSTEM. CONSIST OF 225 TESLA SRV3 ROOF TILES, (2) CENTRAL INVERTERS, (DELTA SOLIVIA 5.2  & 7.6)  AND (2) TESLA POWER WALL. SYSTEM SIZE IS 12.8KW AC & 13.15575KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19155	14041-10000-33829	19200 S WESTERN AVE	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			PC Approved	12/18/2014 12:00:00 AM	ADDRESS	33.85755	-118.30917	T24 . REMODELING AN EXISTING INDUSTRIAL WAREHOUSE DISTRIBUTION. TOTAL AREA 5929 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19156	11041-10000-11994	714 E TRACTION AVE	90013	9	127-5A215  41	5163012007	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	06/10/2011 12:00:00 AM		Permit Finaled	09/20/2011 12:00:00 AM	ADDRESS	34.04535	-118.23623	T.I.  Existing restaurant.  Renovation of the lighting fixtures.  Emergency lights are existing and are to remain.  There will not be any modifications done to the emergency lights.  The emergency lights are subject to field inspection.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19157	15041-10002-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 25  (CHANGES ARE CLOUDED  ON THE PLANS) REVISIONS TO PERMITTED SET OF PLANS.PLAN CHECK ONLY. CHANGES include update of loads on panelboards and on the four distribution boards from the services. .((((((((((  REPLACING DISTRIBUTION BOARDS AND PANEL BOARDS AS PART OF SWITCHGEAR UPGRADE AT TERMINAL 7; SERVICE REMAINED THE SAME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19158	16041-20000-38132	7144 N SALE AVE	91307	12	183B097   880	2024040022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.20025	-118.61883	PV1.  Install 7.6 kW AC roof mounted grid-tied PV system.  Central inverter standard plan.  (38) modules with (1) ungrounded inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19159	18041-10000-34922	2430 E PORTER ST	90021	14	121-5A217 295	5168029024	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.02651	-118.22916	PLAN CHECK FOR POWER AND ENERGY FOR - ADA AND STRUCTURAL UPGRADES TO EXISTING WAREHOUSE SPACE IN ORDER TO BRING UP TO CURRENT CODE. MINOR T.I. IMPROVEMENTS SCOPE - TOTAL CONNECTED LOAD >400A TOTAL AFFECTED AREA = 49953 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19160	13041-10000-32313	2134 N THOMAS ST	90031	1	136-5A225  11	5211007013	RD3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			Reviewed by Supervisor	11/27/2013 12:00:00 AM	ADDRESS	34.07015	-118.20501	PV1, Install 2.25 kW DC roof-mounted solar array for 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19161	16041-30000-31133	4160 N EAGLE ROCK BLVD	90065	1	156A219   159	5472001031	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.12161	-118.22511	Plan check Title 24 only in existing space T.I., remove outdoor HID lighting fixtures and replace with new LED lighting fixtures. Total area: 27,100 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19162	13041-10001-28788	20706 W SKOURAS DR	91306	3	180B109   159	2148010001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.1924	-118.58415	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. STANDARD CENTRAL INVERTER PLAN. SYSTEM SIZE: 9.75 kW DC.(39) TRINA SOLAR # TSM-250P(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19163	19041-10000-21345	200 W MESNAGER ST	90012	1	136-5A217 144	5409003040	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Apartment			07/02/2019 12:00:00 AM	05/10/2022 12:00:00 AM		Issued	05/10/2022 12:00:00 AM	ADDRESS	34.06793	-118.22864	New 4160V, 600Amp 3 phase 4 wire service. New main distribution board at 5000 amps 480/277V 3phase 4 wire. New panels, equipments and lighting.Building Permit: 18010-10000-05849	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19164	18041-10000-23490	601 W 5TH ST 4TH FLOOR	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for T24 only, TI on existing elevator lobby and corridor on the 4th floor. Install new lightings. Total area: 1,647 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19165	11041-20000-15625	8250 N WOODMAN AVE	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.22107	-118.43251	Plan check power for new installation of 30KVA UPS System for North II Medical Offices. No work in patient care area. New panels, equipment, and ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19166	17041-20000-16584	18549 W ST MORITZ DR	91356	3	165B125   374	2184050023	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.14541	-118.53674	PV1.  Install 14.3 kW DC roof mounted grid tied PV system.  (44) modules with (1) 15 kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19167	15041-20000-23540	6401 N PLATT AVE	91307	12	180B093   780	2033010034	C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.18688	-118.64299	Title 24 plan check only.  Total area = 1,500 sq. ft.  Addition of new lighting to existing restaraunt space.  Existing lighting circuits to be used.  Bugeyes to be installed for emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19168	19041-10000-33683	12100 W OLYMPIC BLVD #120	90064	11	123B149   575	4259025019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.03215	-118.45396	Energy plan check for an office T.I located on the 1st floor of a high rise building. Scope inlcudes new lighting and equipment with a total lighting area of 2,334-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19169	13041-20001-07506	19155 W OXNARD ST PV1	91356	3	177B121   606	2156001022	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.17945	-118.55096	ROOF MOUNTED PHOTOVOLTAIC (SOLAR) SYSTEM 4.41KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19170	13041-20000-02586	43 N BEVERLY PARK CIR	90210	4	153B161    34	4386014023	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	ADDRESS	34.11687	-118.41705	1200 am,p. service, main house 35074, sq-ft, guest house 3100 sq-ft, both houses two stories with 60 amp emergency generator, basement, theater.  PLAN CHECK ONLY, Permit is on a separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19171	14041-10000-33634	3033 W WILSHIRE BLVD	90010	10	135B197  1253	5077008017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.06198	-118.28733	This is a temp power for a18 story mixed use apartment bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19172	19041-20000-35554	6251 W 78TH ST	90045	11	099B165   213	4106017001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	10/12/2019 12:00:00 AM	ADDRESS	33.96987	-118.39436	Plan check for PV roof mounted system, PV System size: 12.21KW DC, 10.378KW AC with 37 PV Modules and 1 inverters(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19173	11041-20000-11335	127 S SAN VICENTE BLVD bulletin-39	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Closed	02/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision to bulletin # 39	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19174	13041-10000-15254	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Info Complete	07/05/2013 12:00:00 AM	ADDRESS	33.97615	-118.42138	pc for power only. EXISTING BUILDING (WAREHOUSE). UPS AND IT EQUIPMENT. new service from 480V to serve new loads and existing 2 panels MS1 and MS2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19175	12041-20000-09896	5060 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2197.00, 2360.00, 2362.02	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.02015	-118.35387	Remodel. Ralph's store. Plan check for power and energy. 59333 SF condtioned and 20575 exterior SF. Single story commercial grocery store building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19176	18041-20000-34952	9051 N WILDWOOD AVE	91352	7	195B177   145	2544031002	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.23366	-118.35405	Plan check for PV roof mounted system, system size: 12.8KW AC with 40 PV Modules and 2 inverters(7.6KW and 5.2KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19177	19041-10000-48904	950 W 190TH ST	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	02/19/2020 12:00:00 AM		Permit Finaled	08/18/2020 12:00:00 AM	ADDRESS	33.85814	-118.29219	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS A NEW FIRE ALARM PANEL WITH 10 POWER SUPPLIES, AND ONE GRPAHIC ANNOUCIATOR, AND ONE COMMINUCATION PANEL AND ABOUT 540 FIRE ALAM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19178	17041-10003-39398	189 S THE GROVE DR Q10-A	90036	4	138B177  1132	5512003042	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.07125	-118.35662	PLAN CHECK FOR CHANGES TO TITLE 24 PLANS - PLAN INCLUDES ADDITION OF NEW LIGHTING AND REVISING TITLE 24 DOCUMENTS ALL CHANGES UNDER DENTA #6[Plan check only, permit is covered under master # 17041-10000-39398] 2nd revision to approved plan, noted as Delta-4, SOW: relocate receptacle and tele/data outlet and rear sales area wall for dispaly lightings, revise lightng switch bank detail, and revise panel schedule to reflect changes to receptacles. <<<PC FOR CHANGES TO APPROVED SET TO REFLECT LIGHTING CHANGES. SCOPE INCLUDES CHANGES TO FIXTURES AND REVISION TO T-24 FORMS. THIS IS PLAN CHECK ONLY!PERMIT UNDER MASTER. T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN AN EXISTING MERCANTILE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 598 SQ. FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19179	15041-20001-33675	23164 W VENTURA BLVD	91364	3	171B097   865	2042006078	QCR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	9304.01	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Expired	02/07/2018 12:00:00 AM	ADDRESS	34.16265	-118.63037	Change to approved set of plans. Changes include Gas Generator to UPS and addition of a panel; some of the load  in panel E1A  are relocated to panel P2A . Changes apply to Delta 1 only. {{{{{{{ PLAN CHECK FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19180	16041-20000-40950	10252 ANGEL LANE	91331	7	204B165   428	2537004038	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25698482	-118.40442298	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19181	11041-20000-13092	1100 S GLENDON AVE 16th fl	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	08/08/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	energy plan check 16th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19182	12041-10000-19198	7746 N ATOLL AVE	91605	2	189B157   879	2303010008	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM			Corrections Issued	08/15/2012 12:00:00 AM	ADDRESS	34.21128	-118.41994	Plan check new roof mounted 5.61KW photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19183	15041-10004-29072	1120 S GRAND AVE	90015	14	126A207    60	5139020024	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			08/31/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.04095	-118.26231	8/31/2017 CHANGED TO APPROVED SET UNDER DELTA 7. SCOPE INCLUDES NEW TRANSFORMERS(2) 9KVA & 15 KVACHANGES TO SOME FIXTURE AND REVISIONS TO TI-24ADDITIONAL RECEPTACLES TO RES. UNITS ADDITIONAL CIRCUITS TO COMMON AREAS.THIS PLAN SHALL HAVE A PERMIT FOR THE ADDITIONAL CIRCUITS AND TRANSFORMERS. **************************************************************09/28/2016 Plan check for power and energy changes to an approved set of plans. Changes include  size of the transformer from 225 KVA to 300KVA and 500KVA, changes to lighting layout. All changes under delta 6.** This is Plan Check only, Permit shall be issued under the master PCIS# 15041-10000-29072** ((((((((New 41 story apartement  building, 536 units. PC for Power and Energy. FA variance on file.Building app. under 13010-10000-03761 architect to update building submittal at a later time.**Fees per applicant, additional fees may apply.)))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19184	12041-10000-18836	3699 W WILSHIRE BLVD	90010	10	132B193    26	5503028020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Public Safety Only			08/10/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.06195	-118.30636	PLAN CHECK UPGRADING AN EXISTING FIRE ALARM SYSTEM. 13-STORY HIGH RISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19185	13041-20000-04391	19409 W PLUMMER ST	91324	12	198B117    40	2761003022	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	34.2429	-118.55623	New 10.5kw Photovoltaic system.  Rooftop mounted on an existing single family dwelling.  System is UNGROUNDED.  Permit include new 200A main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19186	14041-20001-15118	829 N KENMORE AVE	90029	13	141B197    23	5538009007	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.08673	-118.29714	Fee for expedite only****New roof mounted PV system with optimizers and transformerless inverter.  Total system size 5KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19187	14041-10000-17083	609 E ROSE AVE	90291	11	111B141   207	4240003002	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	33.99941	-118.47189	PROPOSED CHANGE OF USE FROM EX RETAIL TENANT SPACE TO RESTAURAN/ UNROOFED OUTDOOR EATING AREA.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19188	17041-20002-37564	407 E 120TH ST	90061	15	084B205  1139	6083029027	R3-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			05/02/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	33.92385	-118.26736	Changes to approved set of plans.  Change of interconnection details for PV system into building wiring system.  Approval for clouded changes only. (((Plan check for solar pv system mounted on carport in apartment complex. System is serving apartment building 1. Total system size: 22.8kW ungrounded.(3) SolarEdge 7.6kW inverters. (108) 280W pv modules.Each module has a 300W power optimizer.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19189	13041-20000-00592	8900 N DE SOTO AVE	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for energy and emergency lighting. 8586 total sqft. (indoor conditioned + unconditioned + outdoor)New industrial manufacturing building (Foam Booth).  NOT A HAZARDOUS/CLASSIFIED AREA PER APPLICANT.  Load is less than 225 amps per applicant.  PLAN CHECK ONLY for Energy, NO Emergency lighting is part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19190	16041-10001-37977	1227 W 187TH ST	90248	15	060B197   309	6109011007	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	33.86137	-118.29532	01/27/2017 Changes to an approved set of plan. Changes include removed Locus Meter from single line diagram. Changes has been clouded. ((((((PC FOR ROOF MOUNTED PV. SYSTEM SIZE IS 3.3KWACSCOPE INCLUDES 14 PANELS (TRINA SOLAR TSM-255 PD05.05)10 OPTIMIZERS-SOLAREDGE P3001 INVERTER (SOLAR EDGE SE3000A-US))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19191	12041-20000-00133	16345 W GLEDHILL ST	91343	12	198B137   145	2676010023	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.24213	-118.48882	Enphase inverters installed on roof of single family dwelling.  A variance to installe Enphase M215 inverters was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19192	19041-10000-37385	5953 N SEPULVEDA BLVD	91411	4	177B145   461	2243001003	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	ADDRESS	34.17893	-118.46651	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19193	12041-10000-12909	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	06/11/2012 12:00:00 AM		Permit Finaled	11/07/2012 12:00:00 AM	ADDRESS	34.05885	-118.44283	Twenty five story high rise plus 5 level parking, fire alarm replacement system, 912 devices , one main panel and 3 aux. panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19194	18041-10000-10920	14611 W POLK ST	91342	7	222B149   416	2505009022	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.30609	-118.45183	plan check for a roof mounted pv system. system size = 3.8KVA consisting of central inverter (SE3800H-US) with 14 panels using P320 power optimizersDC power = 4.06 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19195	16041-20000-34622	5902 W SUNSET BLVD	90028	13	147A191    82	5545015001	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	12/03/2016 12:00:00 AM	ADDRESS	34.09788	-118.3182	Plan check for power and enery. Project site is an existing commercial tenant space. Project scope is a change of use from restaurant to dental office/tenant improvement. Total lighting area = 905 sq. ft.Partial permit fees paid for 20 outlets and 2 fans already under 16041-90000-32037.  10 new branch circuits charged to cover additional fees needed.  Note: Building permit has been pulled under 16016-20000-18094.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19196	19041-20000-53363	9755 N TOPANGA CANYON BLVD	91311	12	201B101   274	2727012065	(T)(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			Reviewed by Supervisor	01/13/2020 12:00:00 AM	PIN	34.24791025	-118.60679957	NEW 3000 AMP 208 SERVICE WITH NEW PANELS, EQUIPMENTS AND LIGHTING. NOTE PER BUILDING 4 STORY HOTEL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19197	10041-10000-03687	800 W WILSHIRE BLVD 11TH FL	90017	9	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.0493	-118.25841	REPLACE EXISTING 3-LAMP PARABOLIC LENS WITH NEW 2-LAMP FLUORESCENT FIXTURESPLAN CHK SI FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19198	18041-20000-26136	8007 N JAMIESON AVE	91335	12	189B129   414	2101011012	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.21592	-118.52214	Plan check for PV roof mounted system, system size: 5.0kW with 18 modules and 1 inverter(5.0kW) connected to Center fed.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19199	13041-20000-11866	4221 W WILSHIRE BLVD 210-220	90010	4	132B189    20	5504001014	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.06194	-118.32113	RENOVATION OF EXISTING OFFICE SPACE. REARRANGMENT AND REPLACEMENT OF SOME FIXTURES. PC FOR T24 ENERGY ONLY. TOTAL  AREA 3810 SQ FT. PERMIT TO BE ISSUED FROM PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19200	15041-30001-41251	333 S HOPE ST Suite E100	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	Changes to approved set.  Changing fixture type and reducing quantity from original plan.      Title 24 plan check only.  Total area = 6,029 sq. ft.    T.I. to section of ground floor in existing commercial highrise.  Remodel of refridgerated wine storage area.  New lighting, receptacles, and compressors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19201	16041-10000-31040	23381 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Issued	02/03/2017 12:00:00 AM	ADDRESS	34.15887	-118.63415	PC for energy only. TI improvements for pet food express retail store. Adding new lighting and power. All existing equipment. Total sqft = 5305.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19202	16041-10000-42818	10250 W SANTA MONICA BLVD 2760 &-2765	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Cinnabon & Auntie Annes"" Ste. 2760 and 2765.  Install (4) new panel,  (1) 75kva tranformer including its circuits, lights and receptacles. Total effected area: 1191 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19203	18041-10000-02137	8466 S FIGUEROA ST	90003	8	097-5A201 129	6032035045	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	33.96195	-118.28249	NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.PC FOR ROOF MOUNTED PV ON COMMERCIAL BUILDNG. SYSTEM SIZE 49.64KWDC AND 53.3KWAC. SCOPE INCLUDES 146 MODULES(REC REC340TP72) WITH 73 OPTIMIZERS(SOLAREDGE  P700 OPTIMIZERS) AND TWO CENTRAL INVERTERS(SOLAREDGE SE20KUS & SE33.3KUS).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19204	14041-20000-24992	4365 S PURDUE AVE	90066	11	111B161   320	4217006021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.00124	-118.41377	PLAN CHECK FOR RESIDENTIAL SERVICE UPGRADE TO TWO HUNDRED AMPS WITH PV SYSTEM SIZED 5KW INTERCONNECTED WITH MAIN SERVICE.PLAN CHECK FOR ENERGY AND POWER.PROJECT FUNDED BY CITY OF LOS ANGELES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19205	12041-10002-04777	9301 N TAMPA AVE # 59A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			PC Approved	04/19/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Correction to 12041-10000-04777 due to inspector's request. Reduced amount of installed lighting. Plan check for energy only. 760 conditioned sqft.PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T.I. FOR COSMETIC SHOP SUITE #59A IN AN EXISTING SHOPPING MALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19206	19041-10001-09706	755 S SPRING ST 1st Flr	90014	14	127-5A211 157	5144015018	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.04336	-118.25369	(PLAN CHECK ONLY) DELTA 1 CHANGES TO AN APPROVED T-24 SET. CHANGES TO CORRIDOR SECTIONS PER FIRE DEPARTMENT REQUEST AND UPDATING LIGHTS AND CONTROLS. Original Scope: ((TI FOR TWO 2 NEW RESTROOMS AND A SERVICE CORRIDOR IN THE COMMON AREAS OF THE FIRST FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BUILDING PERMIT: 15010-10024-00326))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19207	13041-20001-18405	6600 W SUNSET BLVD	90028	13	147A185    65	5547024011	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	04/03/2015 12:00:00 AM	ADDRESS	34.09782	-118.33334	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2.  CHANGES INCLUDE DISCONNECT FOR CAR LIFTS, IRRIGATION CONTROLLER, OUTDOOR LIGHTING.NEW CONSTRUCTION/EXPANSION OF EXISTING MIX USE/RETAIL AND OFFICE SPACE. PC FOR POWER AND ENERGY. NEW 1600A SERVICE. EXISTING BUILING TO CONNECT TO NEW CONSTRUCTION. NON HAZARDOUS AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19208	16041-20000-25399	7537 N VINELAND AVE	91352	2	186B173   375	2315013008	RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.20777	-118.37064	NEW FIRE ALARM SYSTEM 31 DEVICES 1 CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19209	19041-10000-27239	3860 S VICTORIA AVE	90008	10	117B185   855	5045019024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Issued	08/05/2019 12:00:00 AM	ADDRESS	34.0156	-118.3366	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 26 MODULES USING P400 OPTIMIZERES WITH 2 ESS(TESLA POWERWALL) CONNECTED TO NEW 200A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19210	11041-10000-25238	865 S FIGUEROA ST 8thFL	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.04653	-118.26275	remodeling office spacesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19211	15041-10000-22024	5000 N VAN NUYS BLVD #205	91403	4	171A151   223	2248008087	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.16138	-118.44849	OFFICE T.I. ENERGY PC OVER THE COUNTER.  NEW LIGHTING AND RECEPTACLES WITH EXISTING CIRCUITS. TOTAL AREA IS 1646 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19212	15041-20000-18183	6015 S BROADWAY	90003	9	105B201   634	6005004022	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	33.98457	-118.27849	Plan check for Title 24 only Fernando's Upholstery. This is fire loss restoration project, all existing installations are replace with new. Total area: 5204 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19213	10041-20000-08626	10369 N BALBOA BLVD	91344	12	204B133    62	2695020024	C2-1L, P-1L, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	06/07/2010 12:00:00 AM		Permit Finaled	09/22/2010 12:00:00 AM	ADDRESS	34.25908	-118.50258	CHANGE OF USE FROM RETAIL TO RESTAURANT. (999SF). Lighting and power. This P/C is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19214	12041-20000-16763	19300 W SHERMAN WAY	91335	3	183B117    98	2130028001	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			Corrections Issued	07/19/2012 12:00:00 AM	ADDRESS	34.20088	-118.55408	T-24 lighting plan check for new school building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19215	12041-10000-11038	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	34.07149	-118.19797	NEW CAFETERIA FOR OFFI FULL PLAN CHKCE WORKERS AT THE FOREVER 21 DISTRIBUTION OFFICES/WAREHOUSE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19216	14041-20001-24830	7010 S HOOVER ST Unit #1	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #1. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19217	13041-10000-13682	138 N BEAUDRY AVE	90012	1	133-5A211 123	5160030015	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.06001	-118.2534	PLAN CHECK FOR POWER. CHANGE OF USE FROM RETAIL TO (6) LIVE/WORK UNITS ON GROUND FLOOR;  4,987. COMMON AREA LIGHTING IN SCOPE OF WORK added due to building requirements. Outdoor receptacles may not be required since there is no outdoor property - to be verified by plan checker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19218	14041-10000-35428	20841 W PRAIRIE ST	91311	12	198B109    76	2748002054	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.24107	-118.58775	REPLACE 400W HID WITH LED LUMINAIRES; ADDED OS ; OTHER LUMINAIRES REMAIN IN PLACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19219	15041-20000-40916	17046 W COTTER PL	91436	5	162B133    91	2292010029	A2-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	02/27/2016 12:00:00 AM	ADDRESS	34.14293	-118.50458	PV1.  Install 24.4 kW DC roof-mounted, utility-interactive PV system.  (75) SunEdison F325BzC modules with (2) DC combiner boxes and SolarEdge SE10000A-US transformerless inverters.Note: Fee $0 due to SB-1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19220	14041-20000-08284	14326 W CHANDLER BLVD UNIT 2	91401	4	171B153   130	2248016***	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	Apartment			03/27/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.16822	-118.44508	PV2. CONDOS. PV SYSTEM 12 MODULES USING MICROINVERTER. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19221	17041-10001-09438	3648 W SLAUSON AVE A-B	90043	8	108B185   950	4004004014	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	33.98882	-118.3369	PC for T24 only for new lighting in office spaces A and B. Installing new lights. Permit fees where paid under 17041-70000-09438	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19222	16041-20006-12885	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.21922	-118.44896	PLAN CHECK ONLYSUPPLEMENTAL FOR CHANGES TO APPROVED SET, ADDITION OF LIGHTS AND OUTLETS TO PENTHOUSES, UPDATE TO LIGHTING FIXTURE SCHEDULE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19223	15041-10000-08972	525 S HEWITT ST	90013	14	126A215    69	5163023900	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.04076	-118.2351	INSTALL NEW FIRE ALARM SYSTEM. 88 devices and one panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19224	15041-10000-26609	11390 W OLYMPIC BLVD STE. 200	90064	11	123B153    61	4260018021	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.03709	-118.44273	PLAN CHECK FOR ENERGY ONLY FOR EXISTING 4 STORY OFFICE BUILDING. SCOPE OF WORK IS ON THE 2ND FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19225	08041-20007-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to Previously approved set of plans.  Plan Check Only for DELTA #218 Only.<<<<NEW HIGH RISE BUILDING - MEDICAL OFFICE (SHELL ONLY)P/check is approved subject to the ""Conditions of Approval"" on a request for modification regarding campus style feeder to a fire pump.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19226	10041-20000-22907	725 S FIGUEROA ST 3rd floor	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	34.04886	-118.26071	T.I. to a high rise building in 3rd floor.  Install general/emergency lighting in lounge, office, storage areas as shown on plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19227	19041-10000-15149	5788 W ADAMS BLVD	90016	10	123B173  1000	5048008027	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	06/12/2020 12:00:00 AM		Permit Finaled	09/10/2021 12:00:00 AM	ADDRESS	34.03223	-118.36979	FULL PC POWER AND ENERGY. SCOPE INCLUDES A NEW 800A 120/208V 3 PHASE 4 WIRE SERVICE. TOTAL AFFECTED AREA IS 15,865SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19228	13041-20000-30825	11601 W WILSHIRE BLVD 6TH FLOOR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	T24 FOR EXISTING OFFICE BUILDING. SCOPE OF WORK IS ON THE 6TH FLOOR IN SEVERAL OFFICES. 2930 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19229	16041-10000-14293	143 N LARCHMONT BLVD	90004	4	138B189   782	5515019019	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.07426	-118.32382	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE (PERVERSE SUNGLASSES). SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 325 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19230	13041-10001-32386	9709 N GLADBECK AVE	91324	12	201B121   455	2763033028	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.24674	-118.53983	Expedited RSES plan check per applicant request.(((PV1, Install 6 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformered inverter. Fronius IG 5100 NEG. 24 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19231	17041-10001-24210	9301 N TAMPA AVE #212	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Closed	10/02/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Supplemental PC for power and energy for changes to approved set to Dave and Busters restuarant. Scope includes removing and relocating equipment, devices and lighting. Installing new circuits in electrical rooms and updating HVAC roof layout. All changes clouded under delta 6 and delta 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19232	15041-10002-27151	22516 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	33.82154	-118.30136	CHANGES TO APPROVED SET OF PLANS. ADD PERFORMANCE METER AND FUSED DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19233	18041-20000-16891	12910 N SAN FERNANDO ROAD	91342	7	222B145   153	2501006033	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.30526	-118.46597	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19234	12041-10001-13681	621 S WESTERN AVE 111-117	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM			PC Approved	09/10/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	REVISED LIGHTING PLAN BY RELOCATING SOME LUMINAIRES BUT KEEPING THE INSTALLED WATTAGE THE SAME;CHANGE OF USE OF 1ST FLOOR TENAT (7) SPACES FROM RETAIL TO RESTAURANT AND AMUSEMENT ENTERPRISE.  Existing service.  Full Plan Check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19235	11041-10000-00284	615 W CHILDS WAY	90089	9	118-5A201  27	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM			PC Info Complete	01/06/2011 12:00:00 AM	ADDRESS	34.0191	-118.28214	Basement of USC lighting and title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19236	19041-20000-45718	1001 N HELIOTROPE DR	90029	13	144B197   993	5538019009	RD1.5-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.08956	-118.29513	PV1.  Install 9.9 kW roof mounted grid tied PV system.  (30) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19237	15041-20002-31569	1457 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			PC Approved	03/17/2017 12:00:00 AM	ADDRESS	34.09731	-118.31598	[[3/17/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 5 CHANGES HAVE BEEN UPDATED WITH FAULT CURRENT CALCULATIONS. ADDITIONAL CIRCUITS FOR UV LIGHTS HAVE BEEN ADDED. PANELBOADS HAVE BEEN UPDATED.]]]02/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. There have been removal and relocation of electrical and mechanical equipment.*****Previous Work Description*****Plan check for power and energy. TI to existing  commercial building (5 floors). not a highrise per applicant.  Total sqft. 14,228.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19238	15041-10000-30823	25481 S DODGE AVE #9	90710	15	036B197  1118	7413024***	(T)(Q)R3-1-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	33.79295	-118.28922	INSTALL 5.565 KW DC ROOF-MOUNTED ROOF-MOUNTED ON  A SINGLE FAMILY HOUSE.(13) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19239	11041-10000-09858	14545 W ERWIN ST	91411	6	178-5A151 211	2241012027	[Q]C1.5-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.18376	-118.45033	energy title 24 office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19240	19041-10000-25223	500 WORLD WAY Terminal 5-Level 3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	Energy plan check. Scope includes new lighting and equipment within LAX terminal 5, level 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19241	15041-20002-18437	14885 W EL CASCO ST	91342	7	225B149   436	2505029005	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.30989	-118.45713	Expedite per applicat request[[[[Plan check for PV roof mounted system.  System size 8.9kW with 35 modules and 35 microinverters]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19242	14041-20000-21421	12280 N DERWENT AVE	91326	12	219B121    76	2820001026	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	34.29659	-118.54981	PV1.  Install 5.886 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19243	14041-20000-22144	6631 N FORBES AVE	91406	6	180B133   175	2231021026	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.1912	-118.49922	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 4.515kW(21) EnPhase M215-IG microinverters(21) Hyundai HiS-M250MG pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19244	11041-20001-20483	14800 W VENTURA BLVD Phase-3B	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Approved	12/10/2012 12:00:00 AM	ADDRESS	34.15186	-118.45547	Modification of approved set of plans to reduce scope of work.  Fire Alarm is NOT part of this plan check.  PLAN CHECK ONLY for Delta 3 Changes Only.       <<<<<<<< PHASE 3B complete plan check.  Request for Modification to separate Fire Alarm system filed .>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19245	11041-10001-18978	5757 W WILSHIRE BLVD #360	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	ADDRESS	34.06259	-118.35341	REVISION TO APPROVED PLANS. DELTA 2 REVISIONS. FIELD CHANGES, LIGHTING, AND T24 CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19246	10041-10000-16163	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Expired	11/21/2012 12:00:00 AM	ADDRESS	34.10191	-118.28217	Fire alarm sysrem addition for ABC TALMADGE  bungalow Bldg C and the Cottages bui lding E.  2 panels and 35 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19247	15041-10000-02672	12020 W CHANDLER BLVD 3rd fl	91607	2	171B165   117	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.16825	-118.39512	Title 24 plan check only.  Total area = 12,081 sq. ft.T.I. on 3rd floor of existing 4 story office building.  Reuse of existing circuits and panels, new recepticles and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19248	12041-10000-20446	888 S FIGUEROA ST	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.0465	-118.26225	ON THE 3RD FLOOR, REMODELING EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19249	11041-20000-11061	17656 W CHATSWORTH ST	91344	12	207B129   463	2733009001	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM	06/17/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.26465	-118.5193	PLAN CHECK POWER AND ENERGY FOR A CHANGE OF USE TO DENTAL OFFICE. EXISTING PANELS AND AC EQUIPMENT. NEW CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19250	19041-20000-39099	18416 W CHATHAM LANE	91326	12	213B125   240	2870016036	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM			Not Ready to Issue	09/27/2019 12:00:00 AM	ADDRESS	34.28152	-118.53427	PV1.  Install 11.4 kW AC / 11.34 kW DC roof mounted grid tied PV system.  (36) modules with 7.6 and 3.8 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19251	14041-20000-26673	14006 W RIVERSIDE DR #9030	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	New retail kiosk in existing mall/shopping center.  Plan check for TItle 24 Part 6 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19252	19041-20001-51055	4311 N LOUISE AVE	91316	5	165B133   212	2292017013	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.14994	-118.50689	Expedite per applicant request. Plan check for PV roof mounted system, PV system size: 11.34KW with 36 PV Modules and 1 inverter(10.0KW), Energy Storage System size: 40.5KWh, 3 Energy Stroage System Tesla Power Wall connected to Existing 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19253	10041-10000-03134	701 N STONE CANYON ROAD CENTRAL-BLDG	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	UPGRADE TO THE CENTRAL PLANT BUILDING AT THE BEL-AIR HOTEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19254	18041-20000-43757	20814 W SPRUCE CIR #67	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.29506	-118.58781	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19255	17041-20000-36713	6842 N VAN NUYS BLVD	91405	6	183B149   647	2217009011	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	07/29/2020 12:00:00 AM		Permit Finaled	06/23/2021 12:00:00 AM	ADDRESS	34.19499	-118.44846	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from office and restaurant to educational/tenant improvement. Total lighting area = 8,014 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19256	15041-10000-33065	1862 N MANGO WAY	90049	11	135B137    86	4426008020	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2015 12:00:00 AM			Corrections Issued	01/14/2016 12:00:00 AM	ADDRESS	34.0681	-118.49648	New 3-story single family dwelling over two level basement with attached garage and attached deck.NOTE PERMIT 15010-30000-01364 IS FOR AN ACCESSORY BLDG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19257	15041-10000-31200	523 W 6TH ST STE.220	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	PIN	34.04872199	-118.25441618	PC for energy only, TI on existing office 2nd floor (12 story historic bld). Total area: 5023sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19258	19041-10000-19312	1600 S FIGUEROA ST	90015	14	124-5A205  26	5134008003	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.03733	-118.26993	"FULL PLAN CHECK FOR A TENANT IMPROVEMENT TO EXISTING AUTO REPAIR GARAGE IN PREPERATION FOR NEW  AUTOMOTIVE SERVICE CENTER FOR TENANT ""LYFT"". CAR RENTAL,  AUTOBODY REPAIR, BRUSH PAINTING -NO SPRAY BOOTH, CAR STORAGE & OFICE. SCOPE INCLUDES NEW 1000A 240/120V SERVICE, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 11691 SQ.FT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19259	14041-20000-20693	22815 W CALABASH ST	91364	3	168B097    76	2075019013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.16005	-118.62441	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING IVNERTER USING STANDARD PLAN. TOTAL OF 22 MODULES.(1) SMA sunnyboy SB5000US transformered inverter(22) SolarWorld 270W pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19260	13041-10000-26216	100 UNIVERSAL CITY PZ stage  #3	0	4	162B177	2424044015	C2-1, PB-1					1437.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM				replacing high bay luminaires -supplied from existing ckts and lighting area ctrls  for shut-off ctrl;EMERGENCY LUMINAIRES REMAINED THE SAME PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19261	19041-20001-24835	13766 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM			PC Approved	09/04/2019 12:00:00 AM	PIN	34.30869959	-118.43368746	Revisions to approved set of plans.  Minor modificatons to lighting plan; SLD revisions not subject to plan review.  (((ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19262	17041-10000-12653	2300 S CENTRAL AVE	90011	9	118-5A211  46	5119007001	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.02057	-118.25386	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 26,825 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19263	13041-10000-27344	5570 N FIGUEROA ST	90042	1	151-5A229 359	5468025001	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.10879	-118.19405	Change to lighting in an existing restaurant.  Load is less than 400 amps.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19264	13041-10000-33978	10759 W PICO BLVD	90064	5	126B157   785	4320004091	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.04124	-118.42652	PLAN CHECK FOR T24 ENERGY ONLY. EINSTEIN BAGEL. 2857 SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 13041-10000-32065. T24 PER INSPECTORS REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19265	18041-10000-08741	2670 N GRIFFIN AVE	90031	1	139-5A223  15	5206010035	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.07841	-118.21167	Plan check for PV ground mounted system for carport. System size: 60kWac with 144 modules and 1 inverter (60KW) B#17010-10000-05012Note: There are existing system within the property	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19266	17041-10003-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	SUPP. PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER BULLETIN 9 (SUNSET DECK) UNDER DELTA 7. SCOPE INCLUDES REVISIONS TO LIGHTING INCLUDING T-24 FORMS REVISIONS,  ADDITION AND REMOVAL OF CIRCUITRY INCLUDING REVISIONS TO PANEL SCHEDULES TO REFLECT CORRECT LOADING. THIS IS PLAN CHECK ONLY. ALL PERMIT ELEMENTS UNDER BULLETIN 12 DELTA 9.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19267	13041-20000-28008	12663 N GLENOAKS BLVD	91342	7	219B153    17	2508027013	QC4-1, QP-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.29972	-118.44048	T24 FOR EXISTING RETAIL SPACE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19268	14041-20000-32169	5045 N EAGLE ROCK BLVD	90041	14	162A221   160	5686002011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.13828	-118.21463	Plan check for energy only. TI to existing retail space. Interior remodel. Change from Quiznos to a Yogurtland. New lighting, inlc. emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19269	18041-10000-07457	1001 S PACIFIC AVE	90731	15	015B197  1094	7454012027	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	33.73492	-118.28809	PC for T24 only for replacement of indoor-outdoor existing fixtures with LED fixtures for Chase bank. Total area Indoor  is 43232sqft.Plan checker to verify address	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19270	18041-20001-39950	5100 E RANGE VIEW AVE	90042	14	156A225    54	5479027016	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.12353	-118.20385	11-08-2018 Changes to an approved set of plans, Changes include relocate disconnect and inverter and battery all changes has been clouded. Plan check onlyFee $0 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19271	13041-10000-24089	2920-2930 W ROWENA AVE BUILDING 1	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM	04/01/2015 12:00:00 AM		Issued	04/01/2015 12:00:00 AM	ADDRESS	34.10823	-118.26884	NEW BUILDING. APARTMENT.  1 OF 6 TOTAL UNITS. BUILDING 1. NEW 400 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19272	16041-10000-35592	12953 W BRANFORD ST	91331	7	198B161   142	2626015015	RA-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.2401	-118.41469	PC for title 24. Remove outdoor HID fixtures and replace with new LED fixtures. Total sqft = 76940.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19273	18041-20001-36087	11530 W DONA TERESA DR	91604	2	159B169   542	2381012005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2018 12:00:00 AM			PC Approved	10/05/2018 12:00:00 AM	ADDRESS	34.13066	-118.38456	expeditepv1install roof mounted pv system sized 11.3KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19274	17041-20000-08558	1965 N HILLHURST AVE Suite B	90027	4	150B197   560	5590012045	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.10719	-118.28759	PLANCHECK FOR T24 ENERGY ONLY.  TENANT IMPROVEMENT  FOR CHANGE OF USE FROM OFFICE TO MASSAGE ESTABLISHMENT. 3557 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19275	12041-20000-29704	14800 W VENTURA BLVD 8TH FLOOR	91403	5	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.15186	-118.45547	"Plan check only for Lighting (T-24).  No new equipment is part of this plan check or permit.  All new equipment and circuits are on a separate plan check.  Permit fees for Lights only are under ""INSPECTION"".  <<<PLANS ARE NOT CHECKED FOR EMERGENCY LIGHTING.  EMERGENCY LIGHTING IS ON A SEPARATE PLAN CHECK PER APPLICANT.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19276	19041-20000-48662	3527 N WONDER VIEW DR	90068	4	159B185    49	5577004012	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.13239	-118.33748	PV1. INSTALL 19.09 KW DC PV SYSTEM WITH (46) MODULES AND (2) NEW TESLA POWERWALL CONNECTED TO (E) 400 AMP SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19277	12041-10000-02270	7083 W HOLLYWOOD BLVD 103	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.10173	-118.34439	Rewire of existing commercial office (7000 sqft), low-rise. New circuits and lighting change. Plan check only for energy with emergency lighting.PERMIT FEE IS IN THE INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19278	19041-10000-23081	340 N PATTON ST	90026	1	135A209    13	5160009002	CW	Central	Westlake	Echo Park	YES	2080.00	Electrical	Electrical	Apartment			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	04/09/2021 12:00:00 AM	ADDRESS	34.06618	-118.25846	Plan check for a fire alarm system located in a 7-story apartment building. Scope inlcudes (1) fire alarm panel. (3) power supplies and (156) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19279	14041-10000-29438	3434 S GRAND AVE	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Closed	12/05/2014 12:00:00 AM	ADDRESS	34.01912	-118.27658	Plan check for installing service for temp power for 1000amp substation fed from existing MV switch at USC Glorya Kaufman Dance Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19280	18041-10001-02603	11120-11160 S HINDRY AVE	90045	11	087B173    72	4129038015	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Approved	06/21/2018 12:00:00 AM	ADDRESS	33.93344	-118.3722	[[[6/21/18 CHANGES TO APPROVED SET. DELTA 2 CHANGES ARE CLOUDED. PLANCHECK ONLY. RELOCATION OF 800AMP SWITCHBOARD, AND SERVICE FED FROM DWP TRANSFORMER]]]PC for power and energy for new 800A 480/277V service for water treatment plan. Installing new service equipment, 3 panels, re-connecting exising circuits, new water treatment equipment.B# 18016-10000-01497	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19281	15041-10000-23530	644 N HARVARD BLVD	90004	13	141B193   670	5521006008	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.08292	-118.30448	TITLE 24 PLAN CHK FOR INTERIOR COMMON AREAS AND EXTERIOR AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19282	19041-10000-38352	9267 W CORDELL DR	90069	4	144B165   117	4392009012	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.09396	-118.3933	PC FOR PV-1 SYSTEM. SYSTEM SIZE 4.96KW-DC/4.60KW-AC. SYSTEM INCLUDES 16 MODULES (Q-CELL ) WITH P370 OPTIMIZIER. 1-INVERTER SE5000.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19283	13041-10001-34665	1248 N MARIPOSA AVE	90029	13	144B197    69	5540004004	RD2-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	12/30/2013 12:00:00 AM	ADDRESS	34.09466	-118.29931	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, MICROINVERTER NON STD PLAN. 3 KW DC SYSTEM SIZE.UNGROUDED.( 12) 250W MODULES(12) ENPHASE 215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19284	19041-10000-17592	4070 N LAUREL CANYON BLVD	91604	2	165B165  1122	2368002018	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.14555	-118.39579	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19285	14041-20000-33312	1905 W 9TH ST	90732	15	015B189   240	7560026027	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	33.73656	-118.31835	pv1install roof mounted pv system sized 3.8kw interconnected with msp.(17) canadian solar cs6p-250p modules(1) solar edge se3800 transformerless inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19286	11041-20000-05633	555 W 5TH ST 2ND FLR	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO 2ND FLOOR CONFERENCE ROOMS OF (E) OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19287	13041-10000-23766	14931 W CALIFA ST	91411	4	177A149   141	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.17768	-118.4586	CHANGE OF USE: FROM WAREHOUSE/OFFICE BUILDING TO OFFICE BUILDING.  ADD SECOND FLOOR AND TOTAL THREE STORY OFFICE BUILDING.  NEW SERVICE AND DISTRIBUTION SYSTEM.  POWER AND ENERGY.  VARIANCE TO SEPARATE FIRE ALARM PLANS SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19288	18041-20002-33122	12915 W MONTFORD ST	91331	7	213B161   474	2533023015	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.28061	-118.41406	Revision to approved set of plans.  Revised wire size, added service load calculations to justify derating of main service disconnect. (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19289	16041-20000-26766	401 S KINGSLEY DR 1-84	90020	10	135B193   432	5503010025	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.06692	-118.30302	"""0$ permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 40kW with176 modules and 4 inverters(10.0kW) connected to MSP"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19290	16041-20000-17779	7215 N CAMELLIA AVE	91605	2	183B169    79	2316026001	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	11/22/2017 12:00:00 AM		Issued	11/22/2017 12:00:00 AM	ADDRESS	34.20166	-118.38244	Plan check power only for fire damage to electrical equipment(800A rated) in existing building and associated panels. All circuits existing to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19291	19041-10000-52630	200 E WASHINGTON BLVD	90015	9	123A207   186	5127029049	C2-2D-O-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Apartment			12/19/2019 12:00:00 AM	04/12/2021 12:00:00 AM		Issued	04/12/2021 12:00:00 AM	ADDRESS	34.03031	-118.26348	PV2 ROOF MOUNTED SYSTEM. SCOPE OF WORK INCLUDES: (225) PV MODULES, (1) SE43.2, (1) SE14.4, SE9 INVERTERS, (1) 400A PANEL THAT IS CONNECTED TO AN EXISTING 4000A SERVICE.  84.37KW DC AND 66.6KWS AC SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19292	16041-20001-24766	10136 W HOLLOW GLEN CIR	90077	5	156B153   152	4382025***	RE15-1-H-RPD	South Valley, West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	PIN	34.12335252	-118.44234551	EXPEDITED PER APPLICANTS REQUESTInstall a roof-mounted solar array on a SFD. (18) 335W pv modules. MSP is 225A. 6kw Ungrounded system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19293	15041-20000-17775	19143 W VICTORY BLVD #6	91335	3	180B121   534	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/09/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.18674	-118.55078	PV2Plan check for PV roof mounted system on appartment unit 6. System size: 6.0kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19294	13041-10001-22278	4501 W DON ARTURO PL	90008	8	114B177   201	5028013021	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Verifications in Progress	10/03/2013 12:00:00 AM	ADDRESS	34.00954	-118.354	EXPEDITED PLAN CHECK PER APPLICANT REQUEST.  ((((PV1.  INSTALL 14.7 KW DC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN SERVICE PANEL.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19295	14041-10000-00136	1180 S CROCKER ST	90021	14	123A211   487	4243011032	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.03311	-118.25145	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 252 SQ FT. REPLACING TOTAL OF 1 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19296	16041-10000-18155	11766 W WILSHIRE BLVD STE 700	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.04804	-118.46227	PC FOR ENERGY. TENANT IMPROVEMENT: REDUCE SUITE 700 TO NEW DEMISING WALLS.  TOTAL AREA 399 SQ FT. B# 16016-10000-04473	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19297	10041-10000-15103	3131 S FIGUEROA ST Room #118	90007	8	120A203    61	5123010012	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	10/27/2010 12:00:00 AM	ADDRESS	34.02389	-118.27894	TI IN AN EXISTING COMMERCIAL AREA Room #118.    PLAN CHECK IS FOR T-24 ENERGY CALCS.REF.#10044-10000-08248.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19298	08041-10001-17349	1409 S BEVERLY DR	90035	5	132A167   267	4306002016	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			12/07/2012 12:00:00 AM			PC Approved	12/07/2012 12:00:00 AM	ADDRESS	34.05475	-118.39552	New fire alarm system. (original plan was lost, plan was resubmitted for plan check)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19299	12041-10000-21245	801 S HOPE ST	90017	9	129A209   178	5144020195	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.04656	-118.25938	TEMPORARY POWER FOR THE CONSTRUCTION OF NEW HIGH RISE BUILDING  New  high-rise mixed-use building with two 4,000 amp services.  Fees are calculated to match applicants pre-cut check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19300	15041-20000-22245	16000 W VENTURA BLVD 6th flr	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Issued	07/14/2015 12:00:00 AM	ADDRESS	34.15584	-118.48164	Title 24 plan check only.  Total area = 388 sq. ft.  Remodel of bathroom in existing highrise space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19301	11041-10000-17345	1555 W SEPULVEDA BLVD # P	90501	15	045B193   500	7347017068	M2-1VL, [Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	09/23/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	33.81603	-118.30485	tenant improvement in skin care salonplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19302	15041-20000-16782	6316 N TOPANGA CANYON BLVD B 1100	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	TI to existing restaurant (coffee shop). Plan check for power and energy. Adding new lighting including emergency. Total sqft. 1,239.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19303	19041-20000-05084	6600 N TOPANGA CANYON BLVD # 2062	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only in existing retail space Tenant Improvemt. Total area: 9702 sq ft. B#18016-20000-38082	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19304	10041-10000-23147	1933 S BROADWAY	90007	9	123A207     2	5126031010	[Q]M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.03006	-118.26696	TI IN AN EXISTING COMMERCIAL BUILDING (LA MART).  NEW 4160 SERVICE AND NEW PANELS. CORE & SHELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19305	14041-10000-04585	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	33.94221	-118.40701	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR AN EXISTING RETAIL SPACE IN TERMILAN 4 OF LAX. 765 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19306	15041-20000-02014	1985 E ZONAL AVE Bld. PSC	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for a permanent power to replace 4.8KV with 12KV service for existing USC  PSC building.  Install new transformer and switchgears.  No change in connected load.  Plan check for power only.Note: Variance will be submitted for the clearance above the electrical equipment in the electrical room.Note: Temporary power submitted under 14041-20000-26989	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19307	19041-10000-47231	1118 N HIGHLAND AVE	90038	4	144B185   651	5532020008	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			PC Info Complete	11/15/2019 12:00:00 AM	ADDRESS	34.09129	-118.3384	PLAN CHECK FOR TITLE 24 ONLY FOR TI - TOTAL AFFECTED AREA = 2702 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19308	10041-10001-23080	1731 N WORKMAN ST	90031	14	135A221    96	5210006009	M2-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM			PC Approved	12/13/2010 12:00:00 AM	ADDRESS	34.06217	-118.21429	PARKING LOT. ADD 4 NEW POLES. RELOCATE 2 POLES. RELOCATE PANEL. POWER NEW GATE. PERMIT #: 10041-40000-23080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19309	16041-10000-42336	3330 S FIGUEROA ST	90007	9	120A203   195	5123021001	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.02223	-118.27956	PC FOR ENERGY. REPLACE  INDOOR AND OUTDOOR  FIXTURES WITH NEW LED FIXTURES  TOTAL AREA 53000 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19310	15041-20000-36446	11847 W GORHAM AVE	90049	11	129B145  1157	4265018***	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.05206	-118.46883	$0 permit fee is due to Senate Bill SB-1222Plan check for commercial PV roof monted supply side tap system connected to 1,000A Service. System size: 35kW and 16 modules and 5 inverters(2 of 10kW and 3 of 5kW inverter)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19311	16041-20000-38884	22016 W SATICOY ST	91303	3	186B101   176	2023001024	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.20811	-118.60663	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (24) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19312	16041-20000-28312	23233 W SATICOY ST #109	91304	12	186B093    85	2027005005	P-1VL, [Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.2084	-118.63348	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement/change of use from retail to massage parlor. Total lighting area = 1,138 sq. ft.Note: Building application has been generated under 16016-20000-18168	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19313	16041-20000-09437	6254 N BEEMAN AVE	91606	2	177B161   177	2332015002	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Re-Activate Permit	08/23/2018 12:00:00 AM	ADDRESS	34.18458	-118.40724	Fee is $0.00 due to 2012 CA State Senate Bill 1222.Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 15.2kW (7.6+7.6). Ungrounded system. Each module has a 300W power optimizer.(55) 300W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19314	14041-10000-20841	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.18088	-118.48309	plan check for power only. Work on 4 new screw motors (300HP @ 4160V) and 2 new 4160KV motor starters. Other 4 motors are existing to remain. 8 new lube oil pupmps at 480V. Hazardous location - class 1 div 2. Install 6 new supply fans on roof above classified area. Smoke Detectors installed to shut down supply fans for smoke control. For 300 hp motors, feeders are to existing to remain. Addition of 1 branch for compressor room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19315	16041-20000-39055	17038 W OAK PARK CT	91316	5	168B133   574	2289004024	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.15932	-118.5047	Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with a 200A MSP.5kW ungrounded system. (22) 300W pv modules. Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19316	12041-20000-03714	910 S BROADWAY	90015	14	127-5A209 260	5139002017	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM	05/22/2015 12:00:00 AM		Issued	05/22/2015 12:00:00 AM	ADDRESS	34.04197	-118.25618	Expired pc, extended conditioned to pull the permit now.(5/22/15) permit issued.7 STORIES BUILDING COMPLETE REMODELINGRequest for Modification to separate Fire Alarm system filed 05.30.2012	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19317	12041-20000-04574	111 N UNION AVE	90026	3	135A207   116	5159008800	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.00	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.06525	-118.26562	Add new subpanel, chiller, and pumps.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19318	11041-20000-14933	2101 W SAN FERNANDO ROAD	90065	1	148-5A215  40	5442004002	[Q]MR1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.10245	-118.23703	NEW 600 AMP SERVICE, SWITCHBOARD, AND PANELS. ALL LOADS ARE EXISTING TO REMAIN AND PROVISIONS FOR FUTURE LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19319	11041-10000-03839	1100 W WILSHIRE BLVD 2ND FLR	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM			Reviewed by Supervisor	04/04/2011 12:00:00 AM	ADDRESS	34.05228	-118.26384	T.I. NEW MEDICAL OFFICE ON THE 2ND FLOOR.  4 NEW PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19320	10041-20000-16585	11766 W WILSHIRE BLVD 15th-16th floor	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	12/15/2010 12:00:00 AM	ADDRESS	34.04804	-118.46227	Plan check T-24 Energy (general/emergency) lighting on 15th and 16th Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19321	18041-20000-06684	627 N VERMONT AVE	90004	13	141B197   634	5538027028	C2-1	Central	Wilshire	East Hollywood		1926.10	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.08258	-118.29192	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19322	14041-10000-21149	12347 W HUSTON ST	91607	2	168B165   181	2356026020	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.15951	-118.40248	PV1, INSTALL 13.39 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.No fees due to senate1222. medi                                    (57) MODULES: SHARP NU-U235F1 (2) INVERTER: POWER-ONE AURORA PV1-6000-OUTD-US-Z-D	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19323	18041-20000-18161	16741-16753 W SCHOENBORN ST	91343	12	192B137   231	2689012013	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	02/25/2019 12:00:00 AM		Issued	02/25/2019 12:00:00 AM	ADDRESS	34.2228	-118.49793	Commercial service upgrade from 800A 480Y/277V to 2500A 480Y/277V.  Replacement of existing distribution.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19324	12041-10000-23366	6947 N HAYVENHURST AVE	91406	6	183B137   306	2225002011	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Expired	10/27/2014 12:00:00 AM	ADDRESS	34.19704	-118.49256	central monitering , one story	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19325	13041-10002-21489	5837-5841 W SUNSET BLVD UNITS 1-79	90028	13	147A191    55	5545011023	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			05/26/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.09822	-118.3171	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 9 - CHANGE TO FEEDER LENGTHS DUE TO DIFFERENT ROUTING CONDITIONS. UPDATED VOLTAGE DROP AND SHORT CIRCUITS NOTED ON PLANS. THIS IS PLAN CHECK ONLY. NEW ENGINEER PROVIDED FOR DELTA 9 REVISIONS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19326	19041-10001-12111	330 S HOPE ST 2ND FLOOR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM			PC Info Complete	01/06/2020 12:00:00 AM	ADDRESS	34.05319	-118.25252	PC FOR CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA D. SCOPE OF WORK INCLUDES CHANGES TO LIGHTING LAYOU, POWER LAYOUT AND ADDITIONAL CIRCUITS. NO CHANGES TO SINGLE LINEORGINAL SCOPE OF WORK((Full plan check for FIRST TIME TENANT ON THE 2ND FLOOR. Scope includes new lighting and equipment with a total area of  12,671 Sq. Ft.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19327	13041-10000-29116	222 W 6TH ST	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	33.73887	-118.28305	Title 24 plan check only per inspection request.  Original permit under 13041-40000-25892(((CHANGE OUT EXISTING LIGHTING WITH NEW. (REFERENCE BLDG. PERMIT # 13016-40000-14501))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19328	16041-10000-33646	1449 N BRONSON AVE	90028	13	147A191   110	5545015006	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM			PC Info Complete	11/29/2016 12:00:00 AM	ADDRESS	34.09711	-118.31813	FULL PC FOR POWER AND ENERGY FOR A NEW 5 UNIT TOWN HOME COMPLEX FREE-STANDING 2 STORY RESIDENTIAL OVER 1 LEVEL SEMI-SUBTERRANEAN PARKING. SCOPE INCLUDES A NEW 600A 120/240V 1 PHASE 3 WIRE SERVICE, NEW SUB-PANELS, NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 8587 SQ. FT. B#16010-10000-04221	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19329	14041-10000-17180	6255 W SUNSET BLVD Suite 1110	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	"permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A per applicant. Emergency lighting installed in high rise . suite 1110 ""Slickdeals"". BLDG#13016-10-20622:INTERIOR NON-STRUCTURAL T.I. NEW PARTITIONS AND FINISHES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19330	10041-10001-16319	7624 W MELROSE AVE	90036	5	141B177   643	5526015027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM			PC Approved	09/27/2010 12:00:00 AM	PIN	34.08343585	-118.35617379	DELT 7 CHANGES TO LIGHTING PLAN- REPLACE INCANDESCENT LUMINAIRES WITH FLUORESCENT TYPE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19331	14041-20001-04620	6253 N COLFAX AVE	91606	2	177B169   192	2334007027	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM			PC Approved	03/05/2014 12:00:00 AM	ADDRESS	34.18447	-118.38794	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19332	14041-20000-24043	15060 W VENTURA BLVD	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.15287	-118.46147	TI TO AN EXISTING COMMERICIAL BUILDING.  SUITE 100.  NEW LIGHTING AND CIRCUITS ADDED.  EXISTING PANELS TO BE USED.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19333	19041-20002-43384	10420 N DE SOTO AVE	91311	12	204B109    15	2706015017	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM			PC Approved	12/06/2019 12:00:00 AM	ADDRESS	34.25957	-118.58833	12-06-2019 Changes to an approved set of plan, Changes include update main service to 400A and installed fused disconnecting means. All changes has been clouded. Plan check only. Separte permit shall be pull  for any new service install.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19334	18041-10000-42704	1122 W WASHINGTON BLVD ste 340	90015	1	126A201   241	5135014044	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.03877	-118.28233	PLAN CHECK FOR T24 ONLY, CHANGE OF USE AT A PORTION OF 3RD FLOOR FROM OFFICE TO LABORATORY; INSTALL NEW 75KVA TRANSFORMER AND (1) 225A PANEL, NEW CONNECTED LOAD < 200A. TOTAL AREA: 1,506 SQ.FT((B# 18016-10000-31134))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19335	19041-10000-01237	115 E WAVE CREST AVE	90291	11	108A143   145	4238001019	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.99096	-118.47425	pc for pv system. system size is 5.040kw. 14 hyundai 360w HIS-S360RI panels - 14 solaredge optimizers. inverter solaredge SE3800-US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19336	16041-10001-39279	16652 W GILMORE ST	91406	6	180B137   663	2231010037	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.18737	-118.49641	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(20)MODULES-YINGLI YL255P-29B(20)OPTIMIZERS-P300(1)INVERTER-SOLAREDGE SE3800A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19337	15041-10000-24899	6801 W HOLLYWOOD BLVD A1-101A-A1-112	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	Energy plan check for a retail store located in the first floor of a 3-story building; Scope includes new lighting and receptacles; total 1146-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19338	19041-20000-18738	7206 N WHITEHALL LANE	91307	12	186B089   753	2027023014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.20213	-118.65405	Plan check for PV roof mounted system, system size: 10.88kW with 34 PV Modules and 1 inverter(10kW )	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19339	13041-20000-22792	10451 N PEACH AVE	91345	7	207B145   711	2649017012	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.26059	-118.46873	pv1 single family dwelling. total system size 4.3 kw using 20 modules. using microinverter. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19340	18041-10000-20085	3600 E OLYMPIC BLVD	90023	14	118-5A227 231	5191023001	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM			PC Info Complete	12/27/2018 12:00:00 AM	ADDRESS	34.01865	-118.20056	UPGRADE SERVICE TO 2000AMP, 277/480V IN AN EXISTING COMMERCIAL BUILDING. CORE AND SHELL ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19341	11041-20000-11320	4112 N WHITSETT AVE	91604	2	165B165  1171	2367009010	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			06/02/2011 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.14529	-118.40503	New apartment with 15 units.  New 800 Amp service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19342	13041-20000-28862	2403-2407 W 4TH ST	90057	1	135A203   203	5154035003	R3-1	Central	Westlake		YES	2088.02	Electrical	Electrical	Apartment			10/16/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.06409	-118.27662	PC FOR FIRE ALARM. APARTMENT. 165 DEVICES AND 5 RPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19343	19041-20000-16678	22135 W ROSCOE BLVD LOT #8	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	Plan check for PV roof mounted system, system size: 2.1KW with 7 PV modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19344	19041-10000-25102	5960 S CRENSHAW BLVD	90043	8	105B185   258	4005007024	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Issued	07/01/2019 12:00:00 AM	ADDRESS	33.98608	-118.33052	Energy plan check for removing HID fixture and replace with new LED fixture for outdoor lighting with a total area of 6150-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19345	13041-20000-24112	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM			Corrections Issued	09/04/2013 12:00:00 AM	ADDRESS	34.07157	-118.36014	Outdoor Farmers Market. Change to lighting and electrical.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19346	13041-20000-03757	11256 N DENIVELLE PL	91042	7	210B193    85	2552019021	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling	1	Dwelling - Single Family	02/13/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.27367	-118.30154	Photovoltaic system on the roof of a single family dwelling with one inverter and three strings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19347	12041-10000-02278	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM			PC Approved	01/31/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	CHANGE USE FROM RETAIL TO (STARBUCKS) COFFEE SHOP - 858 SF - NO SEATING. EPC IS FOR T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19348	18041-10000-07079	1850 N CHEROKEE AVE	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.10481	-118.33464	Void Application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19349	14041-10000-11894	1911 N HILLHURST AVE	90027	4	150B197   789	5590012046	[Q]C4-1	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.10582	-118.28765	T24 ONLY. TOTAL AREA 1678 SQ FT. RETAIL STORE(VINE SHOP).TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19350	19041-20000-44939	6411 S BROADWAY	90003	9	105B201  1325	6005001002	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Apartment			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	33.98101	-118.27849	PV1 PLAN CHECK FOR NEW 9.9 KW DC/8.415 KW AC PV SYSTEM. SCOPE OF WORK CONSISTS OF (30) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER, AND A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19351	11041-10000-17380	222 W 6TH ST Ste 100	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	11/23/2011 12:00:00 AM	ADDRESS	33.73887	-118.28305	T.I.  Suite # 100 in a high rise office building.  Remodel of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19352	13041-10002-24116	23031 W SYLVAN ST	91367	3	177B097    93	2039011003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2013 12:00:00 AM			PC Approved	11/01/2013 12:00:00 AM	ADDRESS	34.18476	-118.62891	][][]CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGES IS FOR REMOVAL OF (3) DC DISCONNECTS. $0 permit fee is due to the 2012 Senate Bill No. 1222 ][][][ORIGINAL DESCRIPTION: PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 24 MODULES. 3 STRINGS. ON 400A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19353	12041-10000-01214	6868 W GRENOBLE ST	91042	7	207B201   215	2553011020	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Expired	03/18/2014 12:00:00 AM	ADDRESS	34.26146	-118.28103	Plan check  5.74KW ground mounted Enphase M215 microinverter photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19354	13041-20000-15326	9842 W NATIONAL BLVD	90034	5	123B165   967	4311005014	C2-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	PIN	34.03050671	-118.4013386	PC ONLY. PERMIT ALREADY ISSUED UNDER APPLICATION # 13041-20000-09082INSTALL PENDANTS. SUBWAY. PC FOR ENERGY ONLY. CHANGE IN FIXTURES. NO CHANGE IN WIRING AND CONTROLS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19355	13041-20000-35793	16300 W VENTURA BLVD	91436	5	168B137   424	2284001048	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.15674	-118.48819	New mixed-use 49 unit apartment and retail.  2008 NEC. Full Plan Check.  Variance to separate fire alarm has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19356	11041-10000-09622	412 W 6TH ST	90014	9	129A211   109	5144003046	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	06/24/2011 12:00:00 AM	ADDRESS	34.04757	-118.25366	EXISTING COFFEE SHOP.  REPLACING 3 LIGHTING FIXTURES.  TITEL 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19357	18041-10000-37507	11917 W PALMS BLVD	90066	11	117B153  1071	4249013004	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	11/03/2018 12:00:00 AM	ADDRESS	34.01354	-118.43368	PLAN CHECK FOR ROOF MOUNTED 5.0KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SE5000H-US) WITH 17 MODULES USING POWER OPTIMIZERS (P370)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19358	09041-10001-21178	1457 W COLORADO BLVD	90041		162A227    83	5691003013	[Q]C4-2D		Northeast Los Angeles	Eagle Rock	YES		Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM			PC Info Complete	12/12/2012 12:00:00 AM	ADDRESS	34.13954	-118.1965	CHANGES TO PERMITTED SET OF PLANS AS CONSTRUCTION CONTNUES- SERVICE UPGRADE TO 1200A, VOLTAGE  RATING CHANGE TO 120/240V 3PH ,  NEW 400A SECTION (((((((((((NEW MIXED USE PROJECT:  COMMERCIAL (B) , PARKING ( S2) , 8 DWELLING UNITS PV SYSTEM WILL BE REVIEWED UNDER SEPARATE APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19359	10041-10001-10518	1800 S MAIN ST	90015	14	123A207   102	5127024009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/12/2011 12:00:00 AM	ADDRESS	34.03196	-118.26368	CHANGES IN THE LIGHTING SYSTEM- DELTA 6New tenant. Club house. Lighting and power. new 800 amp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19360	12041-10000-30991	7236 W 90TH ST	90045	11	096B157   886	4119031016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	33.9561	-118.42013	PV1 plan check for Microinveter standard plan. Single family dwelling. 1 story unit. using Enphase M215 microinverters and REC 245 PE modules.  System size is 4.16 kw DC (14 Modules) and 3.672kw AC (14 Microinverters).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19361	17041-20001-37249	10303 N NORRIS AVE	91331	7	204B165   123	2537005014	M1-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.25696	-118.40297	2/22/18changes to an approved set of plans.  changes clouded 2/22/18 to matche filed conditions.  this is plan check only.  (((new fire pump to an existing storage building.  plan check for power only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19362	12041-20000-29097	15821 W VENTURA BLVD #160	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.15584	-118.47812	Alteration to indoor lighting system in suite 160.   Plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19363	14041-20000-17606	11755 W WILSHIRE BLVD Ste 1800	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	PIN	34.04869377	-118.46238681	TI to commercial office tenant space in (E) commercial highrise building.  PLan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19364	13041-10000-36026	380 WORLD WAY CONNECTOR-BLDG	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	plan check for power and energy. PROPOSED 4-STORY TYPE IB  ADDITION ( CONNECTOR BUILDING)  BETWEEN  EXISTING  TERMINAL 4  AND THE TOM BRADLEY INTERANTIONAL TERMINAL (TBIT). PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX 68,000 SQ FT.FIRE ALARM VARIANCE FILED ON 12/27/2013	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19365	19041-10000-03898	445 S FIGUEROA ST Plaza-Level	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	08/17/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	ENERGY PLAN CHECK FOR AN EXTERIOR T.I OF A HIGH RISE BUILDING . SCOPE OF WORK INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 6,589-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19366	11041-10000-05711	5555 N VAN NUYS BLVD	91411	2	174B149   958	2249001018	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00, 1288.00	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.1717	-118.44906	4,306 SF CHASE BANK BUILDING.  Full plan check requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19367	15041-10002-01067	12542 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	33.97819	-118.41198	((((5/10/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO ENERGY CALCULATIONS, OCCUPANCY SENSORS AND LIGHTING SWITCHES.  THE CHANGES APPLY TO ALL THE FOLLOWING APPLICATION NUMBERS AS NOTED BELOW.Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps. Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19368	17041-20000-31213	1515 W 190TH ST Suite 400	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	33.85852	-118.30531	Plan check for energy only. TI to existing office suite 400. New lighting (incl. emergency) - 6,261sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19369	11041-10001-02470	1139 S GLENDON AVE	90024	5	132B153   241	4363022010	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/06/2011 12:00:00 AM	ADDRESS	34.06007	-118.44389	Change the approve plan. Delta 2 change on lighting. EPC is for the change. ((((((((((((((((INTERIOR ALTERATIONS OF EXISTING RESTAURANT. PLAN CHK IS FOR TITLE 24 AND 3 EA EMERGENCY CKTS))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19370	12041-10001-18573	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.05295	-118.25675	Modification to T-24 to add Elevator Lobby into scope of work.  PLAN CHECK ONLY for Energ.           <<<Change to lighting, loads, and receptacles to 20th floor of an existing high-rise office building.  Per the engineer, the electrical load is 129Amps.  Plan check is only for T-24 Energy, with Emergency lighting.  Full Plan Check may required if there is any other work in the building with a combined load over 400Amps. >>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19371	19041-10000-02169	9175 N SAN FERNANDO ROAD	91352	6	198B169   176	2631022018	M1-1-CUGU, P-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.23558	-118.39013	REPLACE INDOOR/OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19372	13041-10000-32760	1500 W PACIFIC COAST HWY REC BLDG	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING RECREATION THIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19373	13041-10000-14965	5440 W WEATHERFORD DR	90008	8	117B177   481	5029026004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.01471	-118.3654	PV1.  Install roof-mounted 2.45 kW DC solar array, interconnect with existing main service panel.  {10 modules: Trina Solar TSM-245PC05/PA05.18} {Transformerless inverter: SolarEdge SE3000A-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19374	12041-20000-08051	5433 N ROZIE AVE	91367	3	174B089   649	2047014008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.16941	-118.65186	Photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19375	13041-10000-04706	810 S SPRING ST #B2	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM	03/15/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.04268	-118.25375	PLAN CHECK POWER AND ENERGY FOR RESTAURANT (UNIT #B2) TI. OCCUPANCY OVER 100. ENERGY FEES PAID UNDER APPLICATION #13041-10000-04701.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19376	17041-10000-17754	737 W 30TH ST ROOF	90007	9	121-5A201 161	5123013006	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.02641	-118.28077	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON EXISTING COMMERCIAL BLDG. SYSTEM CONSIST OF 2 INVERTERS (SOLAR EDGE - SE11400A-US-240V), 64 POWER OPTIMIZERS (SOLAREDGE - P400), AND  64 MODULES (SOLARWORLD - SW345 XL MONO)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19377	12041-10000-18057	630 W HARRY BRIDGES BLVD Main Bldg	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	04/26/2013 12:00:00 AM		Issued	04/26/2013 12:00:00 AM	ADDRESS	33.77068	-118.26868	NEW ADMINISTRATION BUILDING.  EPC IS FOR POWER AND ENERGY.  FIRE ALARM IS SUBMITTED SEPARATELY.  Photovoltaic system is on supplemental application.  Building is in a Methane Zone.  Methane detection system is on a separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19378	12041-10000-30059	6736 N ALLOTT AVE	91401	2	180B157    78	2329011027	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.19313	-118.42753	PV1:  New 7.92 KW DC roof mounted PV system for a single family residence.  Applicant is using the standard plan.  Installing 36 modules, 1 combiner box, 1 inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19379	19041-10000-43416	1133 S CRENSHAW BLVD	90019	10	129B189   323	5082026010	C2-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Expired	10/25/2023 12:00:00 AM	ADDRESS	34.05183	-118.32477	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19380	19041-10001-02540	4343 N LANKERSHIM BLVD	91602	4	165B177   566	2423019075	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	08/12/2020 12:00:00 AM		Permit Finaled	03/23/2021 12:00:00 AM	ADDRESS	34.14909	-118.36531	PLAN CHECK FOR CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 25. SCOPE OF WORK INCLUDES A SERVICE UPGRADE TO 3000A (277/480 3P, 4W). THE 3000A SERVICE FEEDS A NEW 3000A SWITCHBOARD WHICH FEEDS EXISITN ELEVATORS AND SUBPANEL. FEEDER SCHEDULE HAS BEEN REVISED FOR THE NEW SERVICE. ORGINAL PLAN CHECKER IS BISHOY -------ORIGINAL SCOPE OF WORK FULL PLAN CHECK FOR AN INTERIOR TENANT IMPROVEMENT OF AN EXISTING MEDICAL OFFICE BUILDING. SCOPE INCLUDES NEW GENERATOR, NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 11,475-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19381	11041-10000-15480	400 S HOPE ST	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	TI TO AN ELEVATOR LOBBY OF AN EXISTING  HIGH-RISE OFFICE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19382	10041-10000-05128	6033 W CENTURY BLVD 400	90045	11	090B169    17	4124030037	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	33.94572	-118.38954	Title 24 for high rise , 4th floor suite 400. and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19383	13041-20000-12625	23324 W SCHOOLCRAFT ST	91307	3	183B093   437	2028015003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.19624	-118.63561	New photovoltaic system.   8.064kw Microinverter rooftop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19384	12041-20000-06068	5405 N AMIGO AVE	91356	3	171B121   121	2161014027	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.16818	-118.53909	Install roof mounted PV system, 7.680KW, SFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19385	13041-10000-03244	2100 W HYDE PARK BLVD	90047	8	105B189   589	6001009010	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.00	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	33.98521	-118.31567	upgrade service to existing warehous/offices;  no new loads at this time;short circuit analysis provide	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19386	17041-10000-24581	2268 E CENTURY BLVD 101-302	90002	15	091-5A217 111	6046019929	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/02/2020 12:00:00 AM	ADDRESS	33.94631	-118.23212	NEW 3 STORY,13 UNIT APARTMENT BUILDING. 600A 208/120 V SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19387	17041-20000-14820	646 N BAYLOR ST	90272	11	129B121   719	4415001008	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Issued	07/10/2017 12:00:00 AM	ADDRESS	34.04749	-118.54315	INSTALLATION OF BATTERY STORAGE AND MULTIMODE INVERTER  TO EXISTING SOLAR SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19388	19041-10000-03766	6505 S MCKINLEY AVE	90001	9	105B205  1194	6007017018	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Issued	01/31/2019 12:00:00 AM	ADDRESS	33.98066	-118.26153	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURE, T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19389	18041-20000-35979	15821 W VENTURA BLVD 4th Floor-Corridor	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for existing corridor renovation high-rise building 4th Floor. New lights, existing circuits. Total area: 4460 sq ft. B#18016-10000-27978	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19390	16041-10000-22736	8500 W BEVERLY BLVD # 778	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT OF AN (E) RETAIL SPACE IN A COVERED MALL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A RETAIL STORE (OMEGA). TOTAL AFFECTED AREA IS 1946 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19391	13041-10001-24753	18609 W COMMUNITY ST	91324	12	192B121   480	2785015030	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.22306	-118.53855	EXPEDITED PER APPLICANTS REQUEST.PV1. INSTALL 4.9 KW DC ROOF MOUNTED SOLAR ARRAY OF 20 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS. DC UNGROUNDED WITH POWER OPTOMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19392	14041-10000-01985	1680 N VINE ST SUITE 604	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	Tenant improvement for office suite in (E) highrise building on 6th floor.  New lighting and power inside unit.  Title 24 plan check and permit for new lighting system. all work will be limited to interior work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19393	15041-10000-10393	938 N CRISTOBAL AVE	90744	15	033B213   720	7425043047	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	33.7834	-118.24286	T24 ONLY. REMOVE HID LLIGHT FIXTURES AND REPLACE  WITH NEW LED LIGHT FIXTURES, TOTAL AREA 6100 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19394	13041-20000-09910	9420 N RESEDA BLVD STE 7	91324	12	198B125   131	2764010041	(Q)C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.24152	-118.53589	Plan check for energy and emergency lighting. Existing tenant. Suite #7.  Sweet Snow To Go Ice Cream.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19395	15041-10000-05330	9729 N LURLINE AVE	91311	12	201B109   204	2748004048	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.24723	-118.5843	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  CHANGE EXISTING LIGHTING FIXTURES.   PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 3723.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19396	16041-10000-21669	321 W 9TH ST	90015	14	127-5A209 127	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.04356	-118.25766	PC FOR FULL PLAN CHECK. 1ST TIME TI TO (N) RESTAURANT. TOTAL AREA 2230 SQ FT.B# 16061-10000-14317	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19397	14041-10000-13483	8570 W COLE CREST DR	90046	4	150A173   757	5556014049	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.10346	-118.37773	Install roof mounted solar array. For residentail with 600amp service connected to battery back up systemSystem size = 8 kW. Inspector to verify available fault current listed on service.. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19398	19041-20000-22249	22135 W ROSCOE BLVD LOT #38	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD.  SYSTEM SIZE IS 2.17 KW DC/1.68 KW AC.  SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19399	15041-10001-14458	8933 N QUARTZ AVE	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.23287	-118.56489	07/05/16Changes to an approved set of plans. All changes are clouded. Changes include adding a gluame and perlin beams on to the plans per inspector's request. Also adding a heat detector.Note: Permit paid under PCIS#15041-10000-14458  ((((Plan check for fire alarm system for office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19400	11041-10000-11450	18545 W ROSCOE BLVD	91324	12	192B125   618	2785018067	C1-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM			PC Info Complete	06/03/2011 12:00:00 AM	ADDRESS	34.22086	-118.5379	"TI IN AN EXISTING ""SUBWAY"". PLAN CHECK IS FOR TITLE 24 - ENERGY CALCS AND EMERGENCY LIGHTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19401	18041-20001-26393	3732 W CLAYTON AVE	90027	4	148-5A203 330	5430009015	R1-1	Central	Hollywood	Los Feliz	Yes	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2018 12:00:00 AM			PC Approved	10/04/2018 12:00:00 AM	ADDRESS	34.10052	-118.27558	10/4/2018changes to an approved set of plans.  changes to relocate battery and AC disconnect in garage.this is plan check only.((((pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.(22) solar city 325W modules(1) delta solivia 7600 string inverter(1) tesla energy storage device 5KW))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19402	17041-10000-00486	11668 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.20103	-118.38683	PC for two new 600 kW Fuel cell installation for Kaiser building. This application is for building on 11668 Sherman Way, and is circled on the cite plan	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19403	12041-20000-00465	10875 N SAN FERNANDO ROAD	91331	7	207B157    70	2619016036	CM-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.26767	-118.42409	Convert use to automobile repair and storage.  Note: Submittal 2 fee is for the changes in design after the original submittal.  The design changes include 1200A new service, main switchboard, subpanels, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19404	10041-20001-17037	3223 W 6TH ST	90020	4	135B197  1267	5502024***	C2-1, PB-1	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	02/16/2011 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.06375	-118.29255	Supplemental from previously approved plans.  Changes include lighting and  install of condensate pumps.  All changes indicate by DELTA-5 as shown on plans.  Plan check for energy only.*****PLAN CHECK POWER AND ENERGY TI IN RETAIL STORE. FIRST TIME TENANT*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19405	17041-20001-43264	7125 W DE LONGPRE AVE	90046	4	147B181   904	5548017035	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.09625	-118.3447	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 66 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19406	16041-20000-37004	10005 N NEVADA AVE	91311	12	204B101   648	2745005038	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	11/12/2016 12:00:00 AM	ADDRESS	34.25186	-118.60959	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19407	17041-20000-19510	5230 N ETHEL AVE	91401	4	171B161   441	2345018052	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.16574	-118.41804	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (42) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19408	12041-10000-15614	6960 N VESPER AVE A-F	91405	6	183B149   391	2219026001	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			Reviewed by Supervisor	07/16/2012 12:00:00 AM	ADDRESS	34.19734	-118.45077	New 16.17kw, tilt up roof mounted photovoltaic system for a new condominum with 6 units on two separate buildings.  Permits for each strcuture shall be separated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19409	15041-10000-28878	642 W 172ND ST	90247	15	066B201   252	6121011056	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	33.87538	-118.28597	PV1. NEW ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 3.00 KW.(18) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-ABB# PVI-3.0-OUTD-S--US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19410	14041-10000-00113	651 S MISSION ROAD	90023	14	124-5A219  39	5171015902	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.03612	-118.22649	INSTALLATION OF A NEW FIREALARM SYSTEM. FULLY SPRINKLERED. 1 PANEL AND 46 DEVICES.HAZARDOUS AREA. WIRING BEING RUN THROUGH EXISTING CONDUIT.ELECTRICAL PC #12041-10000-01814	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19411	13041-10000-10789	2000 S BUTLER AVE	90025	11	126B149   959	4261035003	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Expired	05/21/2015 12:00:00 AM	ADDRESS	34.03919	-118.44625	INSTALLING PV SYSTEM TO SINGLE FAMILY DWELLING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19412	16041-20000-42396	12149 N BELLANDO CT	91344	12	219B125    96	2601074006	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.29499	-118.52583	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (45) modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19413	10041-20000-05270	6200 S VISTA DEL MAR 1-120	90293	11	096B149     8	4116001061	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Apartment			03/23/2010 12:00:00 AM			PC Approved	03/23/2010 12:00:00 AM	ADDRESS	33.96297	-118.4507	LIGHTING IN LAUNDRY AND STORAGE AREA OF AN APARTMENT BUILDING. THIS PLAN CHECK IS ONLY FOR TITLE 24 ENERGY ONLY. PERMIT ALREADY OBTAINED PRIOR TO PLAN CHECK OF PERMIT NUMBER 10041-30000-04530.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19414	19041-10000-42509	2000 S AVENUE OF THE STARS 11th floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.05868	-118.41546	TENANT IMPROVEMENTS OF EXISTING OFFICE AREA ON THE 11TH FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 49,381 SFT. TOTAL NEW ADDED LOAD IS 394 AMPS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19415	14041-20000-18193	722 S GRAMERCY PL	90005	4	132B193   420	5092028030	R3-1	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.05897	-118.31306	PV1Central Transformerless Inverter Standard Plan.Install roof-mounted solar array on SFD. System size: 3.8kW(1) SMA SB3800TL transformerless inverter(15) SolarWorld SW250 Poly pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19416	19041-10000-01062	757 E WASHINGTON BLVD	90021	14	121-5A209 146	5131005012	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.02703	-118.25558	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19417	14041-20000-32982	429 N BOWLING GREEN WAY	90049	11	135B141   398	4402026010	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	34.06638	-118.47774	PV1 SFD. TOTAL SYSTEM SIZE 4.7KW AC USING 22 MODULES. USING MICROINVERTER SYSTEM. USING ENP[HASE M215. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19418	15041-10000-36103	811 W WILSHIRE BLVD STE-1800	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Expired	11/27/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	Energy plan check for an office T.I located in the 18th floor of a high rise building. Scope includes new lighting , receptacles and equipment. Total area is 4305-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19419	16041-20000-03630	13080 W DESMOND ST	91331	7	213B161   128	2524009013	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.28381	-118.41747	Install a roof-mounted solar array on a SFD. System size: 4kW. Ungrounded system.(20) 230W pv modules. Using a standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19420	15041-10001-35464	21825 W ERWIN ST	91367	3	177B105    25	2146029005	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM			PC Approved	01/08/2016 12:00:00 AM	ADDRESS	34.18301	-118.6035	01/08/16CHANGES TO AN APPROVED SET. ALL CHANGES MADE UNDER DELTA 2. CHANGES INCLUDE REMOVING ISOLATED GROUNDING RECEPTACLES.  (((INTERIOR T.I. OF (E) COMMERCIAL SPACE.  PLAN CHECK FOR ENERGY FOR CHANGES MADE TO LIGHTING SYSTEM ASSOCIATED WITH NEW PARTITIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19421	12041-20000-17407	300 S GRAND AVE 33RD FL	90071	14	132A211    50	5149010***	C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Approved	07/25/2012 12:00:00 AM	ADDRESS	34.05283	-118.25116	Energy plan check floor # 33  <<<< fees for permit are under INSPECTION, new lighting, receptacles, loads for an existing high-rise office building on the 33rd floor.>>> energy plan check for the kichen area in addition to approved energy plans for the rest of the floor unmder plan check # 120412000002374	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19422	12041-10000-20996	11333 N SEPULVEDA BLVD	91345	7	213B145   166	2664001801	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1092.00	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.27646	-118.46863	BUILT-OUT SMALL AREA OF AN EXISTING PHARMACY TO A COFFEE SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19423	10041-20000-02289	18818 W BRYANT ST #2,3	91324	12	195B121   463	2785023009	[Q]M1-1VL	North Valley	Northridge			1154.02	Electrical	Electrical	Commercial			02/09/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	02/22/2010 12:00:00 AM	ADDRESS	34.22722	-118.54318	Units ##2,3 t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19424	13041-20000-31274	10526 W DUBNOFF WAY BLDG H	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	05/22/2014 12:00:00 AM		Issued	05/22/2014 12:00:00 AM	ADDRESS	34.18656	-118.36106	PC FOR POWER. NEW 1600A SERVICE AND DISTRIBUTION. BUILDING H OF SERIESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19425	14041-10001-33206	5782 W VENICE BLVD	90019	10	126B177   723	5064026003	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM			PC Approved	04/20/2015 12:00:00 AM	ADDRESS	34.04208	-118.36523	Plan check only for lighting for scope of work described in 14041-10000-33206	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19426	17041-20000-16694	22632 W HAMLIN ST	91307	12	180B097   411	2038023006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.18884	-118.62018	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.3 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19427	16041-10002-39068	6709 W SELMA AVE	90028	13	148-5A185 275	5547014039	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Info Complete	08/22/2019 12:00:00 AM	ADDRESS	34.09981	-118.3367	"DELTA ""3"" CHANGES TO APPROVED of PLANS by plitting one 4000-Amp service into (2) 2000-Amp services, adding (1) panel, (1) elevator, revising feeder length per installation on the field, updating fault current and voltage drop with new services's fault. All changes under delta-3 only. <<<Full PC for new 6 story apartment building (109 units) with subterranean parking garage and retail on ground floor. 21 typical units. New service rated 4000 Amps 208/120 3phase 4wire. Total sqft =103498  Building B.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19428	14041-10001-07932	14175 W TERRA BELLA ST	91331	6	198B153   313	2644012002	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.24119	-118.44212	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(16) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19429	19041-10000-15242	3100 N PASADENA AVE	90031	1	141A223   160	5206002001	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1994.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.08102	-118.2141	PC FOR INSTALL A NEW 3.3KW ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOME WITH 11 PV MODULES. SYSTEM INCLUDES (11) TRINA SOLAR TSM-300DD05A MODULES, (11) ENPHASE IQ7-60-2-US MICRO INVERTER AND (1) LOAD CENTER 125A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19430	11041-10000-19036	1310 E OLYMPIC BLVD	90021	14	123A213   123	5130001042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	34.03161	-118.24389	T.I. TO INDOOR/OUTDOOR LIGHTING TO AN EXISTING MCDONALD'S.  PLAN CHECK ONLY FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19431	11041-20000-13400	4565 W COLORADO BLVD	90039	4	162B201    20	5593012032	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	08/30/2011 12:00:00 AM	ADDRESS	34.14212	-118.27363	New fire alarm system for a church. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19432	18041-10000-04483	5200 N LANKERSHIM BLVD SUITE B	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM			PC Info Complete	01/11/2019 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC for T24 only for restuarant TI. Installing new panel, lights, receptacles and equipment. Total area is 1519sqft. B#18016-10000-03848.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19433	18041-20000-18022	20745 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.29511	-118.58612	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19434	19041-20000-17098	1161 S WESTWOOD BLVD	90024	5	132B153   323	4363023034	[Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.05927	-118.4447	T24 ONLY, PLAN CHECK FOR LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 997SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19435	15041-10000-35065	9637 N OWENSMOUTH AVE	91311	12	201B105   204	2746016018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.24551	-118.60264	T-24, TO AN (E) COMMERCIAL BUILDING. REMOVED HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 2784	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19436	18041-10000-32612	3834 W GLENFELIZ BLVD	90039	13	156A207   393	5435033017	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.12037	-118.26634	Plan check for PV1 7.6kw ACroofmounted system with (24) AC modules interconnecting through the load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19437	19041-20000-49215	8501 N SHIRLEY AVE	91324	12	192B117   304	2783018030	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.22487	-118.55806	PV1. INSTALL 10.8 KW DC PV SYSTEM WITH (30) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19438	19041-20000-15610	3034 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19439	10041-10000-22997	6500 W WILSHIRE BLVD # 1200	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	02/11/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	ALTERATIONS IN AN EXISTINF OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19440	18041-10000-19062	6926 N CEDROS AVE	91405	6	183B149   489	2219013018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.1966	-118.45295	PV1, ROOF TOP SOLAR SYSTEM USING AC MODULES. TOTAL OF (13) AC MODULES, 4.68KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19441	11041-10000-04649	6600 N TOPANGA CANYON BLVD # 26	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	remodeling  in a retail store ( Omega)plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19442	19041-20000-38609	16937 W KNOLLWOOD DR	91344	12	216B133   369	2609003005	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	02/19/2020 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.28769	-118.50002	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 10.64 KW AC/10 KW DC. SCOPE OF WORK CONSISTS OF (28) PV MODULES AND A 10 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19443	11041-10000-01150	440 S VERMONT AVE #108	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			01/20/2011 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	03/11/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	TI IN AN EXISTING RETAIL SPACE IN UNIT # 108.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19444	19041-10000-37032	19329 W LEMMER DR	91356	3	165B117   496	2177036004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.14446	-118.55439	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 12.6KVA PV1 SYSTEM CONSISTING OF 40 MODULES USINF MICROINVERTERS(IQ7X-96-2-US) CONNECTED TO EXISTING 225A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19445	13041-20000-26915	915 W WILSHIRE BLVD Suite 1850	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.05069	-118.2599	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON SUITE 1850. TOTAL CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19446	19041-20000-37589	2636 W RANGE ROAD	90065	14	159A219   243	5684036023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	PIN	34.12975918	-118.2236942	PV1.  Install 8.19 kW roof mounted grid tied PV system.  (26) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19447	16041-10001-06900	4550 N VAN NUYS BLVD	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.15445	-118.4485	ADDITION OF 4 PANELS AND A DISTRIBUTION BOARD INSTALLED IN UNIT 4560 ULTA UNDER CONSTRUCTION OF LANDLORD. THIS IS SUPPLEMENTAL TO CORE AND SHELL SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19448	10041-10000-04233	11312 W HUSTON ST	91601	4	168B173   166	2353023013	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Public Safety Only			03/09/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.15972	-118.37783	NEW FIRE WARNING SYSTEM FOR 14 UNITS 3-STORY OVER GARAGE APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19449	14041-20000-25576	1601 W LOCKNESS PL	90501	15	045B193   434	7347017041	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	33.81813	-118.30556	TI TO EXISTING WAREHOUSE. MAKING NEW OFFICE SPACE AND TI TO WAREHOUSE. NEW LIGHTING. 400A SERVICE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19450	13041-20000-15781	7908 S RAMSGATE AVE	90045	11	099B169   721	4105024014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	33.96721	-118.38094	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.6 KW. USING MICROINVERTER STANDARD PLAN. USING ENPHASE M215. TOTAL OF 12 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19451	15041-20000-28843	1020 N COLE AVE 3rd & 4th-Floor	90038	13	144B185   868	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.08956	-118.32972	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to the 3rd and 4th floor. Total lighting area = 9,619 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19452	13041-10000-30828	16038 W LONDELIUS ST	91343	12	195B141   648	2672026019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.22926	-118.48187	$0 PERMIT fee due to 2012 senate bill 1222PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 8.75 KW.(35) TRINA SOLAR # TSM-250PA05.18(35) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3800A-US(1) SOLAREDGE # SE5000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19453	13041-10001-33210	1133 N VINE ST	90038	13	144B185   591	5533007023	[Q]C2-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Expired	09/09/2016 12:00:00 AM	ADDRESS	34.09171	-118.32698	((5/9/2014- Changes made to approved set. Relocated some loads and changed conduit size on service enterance conductor.))PLAN CHECK FOR POWER AND ENERGY.DESCRIPTION FROM BUILDIN DEPARTMENT: 5 STORY, 112 ROOM HOTEL WITH 1 LEVEL OF UNDERGROUND PARKING (TYPE I-A GARAGE & TYPE V-A RESIDENTIAL ABOVE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19454	17041-10000-25054	3225 W SUNSET BLVD	90026	13	142-5A203  92	5426005005	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.08619	-118.27498	Plan check for title 24 only in existing space, replace outdoor existing fixtues with LED fixtures.Total area: 10,700 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19455	18041-10000-19485	1670 W BEVERLY BLVD #2	90026	13	135A207   236	5153012023	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Info Complete	05/24/2018 12:00:00 AM	ADDRESS	34.06416	-118.26523	CHANGE OF USE FROM OFFICE TO RESTAURANT AND TENANT IMPROVEMENT. TOTAL AREA 920 SQR FT. T-24 ENERGY ONLY.BLDG PERMIT# 18016-10000-06616	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19456	18041-10000-34886	411 S NORMANDIE AVE 1-224	90020	10	135B193   636	5502016007	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	34.06672	-118.30068	PLAN CHECK FOR TEM POWER FOR - New 7- story (5- levels of type III-A over 2- levels of type I-A) over 3- levels of type I-A basement garage with 224- residential units.  Entire building shall be sprinklered per NFPA-13 requirements. - SCOPE INCLUDES NEW 800A SERVICE RATED AT 480/277V WITH AN APPROX. LOAD = 600A OF CONNECTED LOAD - TOTAL AFFECTED AREA = 157,173 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19457	13041-20000-06688	13330 W RIVERSIDE DR	91423	2	168B157   334	2359023003	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.15738	-118.42406	Install a new service to supply multiple building of a school.  There are 5 buildings and a separate permit will be required for each.  Plan check fees to be verified at the time of plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19458	11041-20000-21622	127 S SAN VICENTE BLVD Bulletin-102TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta #102 TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19459	13041-10000-12563	17141 W NANCE ST	91316	5	165B133   277	2292001030	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.14881	-118.5051	PV1 12.74KW ROOFMOUNT NONSTD plan . xfrmless powerone PVI-6000-OUTD-US and PVI-4.2-OUTD-S-US inverters. 52 trina solar modules TSM-245PC05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19460	19041-10000-12038	9225 S AVIATION BLVD	90045	11	093B173    59	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	33.95196	-118.37721	NEW HERTZ CAR RENTAL WITH A 800 AMP SERVICE UPGRADE, CORE & SHELL ONLY. RECONNECT TO EXISTING LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19461	12041-10000-17403	6305 W YUCCA ST	90028	13	150A187   330	5546003016	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Approved	07/25/2012 12:00:00 AM	ADDRESS	34.104	-118.32729	TI IN REST ROOMS ON 1ST FLLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19462	15041-20000-03311	5900 W WILSHIRE BLVD SUITE 520	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.06237	-118.35809	TI TO AN EXISTING HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS.  USING EXISTING CIRCUITS.  SCOPE OF WORK TO BE PERFORMED IN SUITE 520 IN THE 5TH FLOOR. TOTAL SQUARE FOOTAGE 3201. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19463	12041-10000-15851	17259 W RAYEN ST	91325	12	195B133   172	2690003011	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.23229	-118.51063	New 11.772kw rooftop photovoltaic system for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19464	10041-10000-24060	612 W HELLMAN WAY 2nd--8th floor	90089	8	118-5A201   5	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	PIN	34.02015856	-118.28226229	Ti in 7 restrooms. EPC is for T24 and Energy. (2nd-8th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19465	13041-10000-27869	17527 W SEPTO ST	91325	12	201B129    11	2734019004	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.25138	-118.51671	"""$0.00 permit fee is due to the 2012 Senate Bill No. 1222"" PV1. PLAN CHECK FOR ROOF MOUNTED 16KW DC PHOTOVOLTAIC SYSTEM WITH (64) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5(1) FRONIUS # IG PLUS V 5.0"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19466	11041-20000-06674	2228 S WESTWOOD BLVD	90064	6	126B157   393	4320001052		West Los Angeles				2678.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Expired	09/10/2013 12:00:00 AM	ADDRESS	34.04349	-118.43117	PLAN CHECK FOR 57 KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19467	17041-10000-03314	9211 S BEACH ST	90002	15	094-5A213 178	6048025023	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	ADDRESS	33.95286	-118.24201	Plan check for PV roof mounted system. System size: 3.1kW with 10 modules and 1 inverter (3.1kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19468	19041-10002-08729	6509 W DE LONGPRE AVE Panel HP	90028	13	147A187   250	5546014016	C2-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Issued	11/05/2019 12:00:00 AM	ADDRESS	34.09625	-118.33056	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE ADDITION OF (2) AC BATTERIES. _________________________________PV2. NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL COMPLEX. SYSTEM CONSIST OF A CENTRAL INVERTER (SE7600H-US), 22 MODULES (SUNPOWER SPR-E20-435) AND POWER OPTIMIZER (SE P505). SYSTEM SIZE IS 9.57KWdc AND 7.6KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19469	12041-10000-09773	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Public Safety Only			04/30/2012 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	33.94386	-118.4047	NEW FIRE WARNING SYSTEM FOR THE NEW  CENTRAL UTILITY PLANT BUILDING AT LAWA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19470	17041-10000-18461	18726 S WESTERN AVE	90248	15	060B193   331	6108002014	CR-1, R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	33.86066	-118.30895	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19471	14041-20000-22171	11262 N BROMONT AVE	91331	7	210B165   118	2532024011	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.27489	-118.39882	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNECTED WITH MSP.(16) HYUNDAI HEAVY INDUSTRIES HIS-M250 MODULES(16) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19472	16041-10001-10058	1635 N CAHUENGA BLVD 6TH FLR	90028	13	148-5A187 221	5546007028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.10071	-118.32971	This is Pc pC only for T-24, permit under the master E#,  Revise lighting fixtures and layout due to architectural change.  All changes noted under Delta-1<<T-24 FOR A TI IN AN (E) OFFICE BUILDING ON THE 6TH FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 7500. >>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19473	17041-10000-29235	4008 W 3RD ST	90020	10	135B193   211	5502001009	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.06886	-118.30085	PC for T24 only for restuarant TI. Total affected area is 575 sqft. Building #17016-10000-16985.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19474	16041-20000-05641	1230 E 46TH ST	90011	9	112-5A211 259	5107010011	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	07/02/2016 12:00:00 AM	ADDRESS	34.00191	-118.2535	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (13) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19475	15041-20000-05467	342 N FLORES ST	90048	5	138B173   227	5514009006	R1-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Issued	02/25/2015 12:00:00 AM	ADDRESS	34.07726	-118.37093	Installation of new roof mounted solar PV microinverter array.  Total system size = 5.59 kWac.  Two branch circuits with 13 modules each.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19476	18041-10000-14063	1149 S BROADWAY 4TH FLR	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM			PC Approved	04/17/2018 12:00:00 AM	ADDRESS	34.03859	-118.26015	Energy plan check for a new office and conference room T.I. Total area is 518 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19477	15041-20000-16892	11601 W WILSHIRE BLVD 9th-10th	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	PIN	34.0509267	-118.45996763	TI to existing commercial building (office space). Plan check for power and energy. Adding new lighting including emergency. Total sqft. 34, 262	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19478	14041-10000-34251	1234 W WILSHIRE BLVD Suite 106	90017	1	130-5A207 637	5143019***	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Expired	01/05/2017 12:00:00 AM	ADDRESS	34.05329	-118.26612	TI to (E) commercial space, change of use from restaurant to pharmacy.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19479	14041-10000-08007	2525 S TILDEN AVE	90064	5	123B157   413	4256017021	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.03487	-118.43176	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 1.296KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19480	14041-10000-17884	11790 W SNELLING ST	91352	6	195B169   132	2631027001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Expired	08/09/2016 12:00:00 AM	ADDRESS	34.23316	-118.39018	Install roof mounted solar pannels on existing residential building.  Total system size = 6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19481	15041-10000-33495	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.10311	-118.31242	Fire alarm installation to a 6 story commercial building. (1) Fire alarm panel. (2) Communication panels. (6) Control panels. (419) Fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19482	17041-20001-29102	15253 W GOLDEN CT	91342	7	219B145   688	2611041026	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.29481	-118.46533	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6 kWac and consists of (1) inverter, (19) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19483	10041-20000-18197	130 S SEPULVEDA BLVD 1-59	90049	5	138B145   494	4366014032	[Q]R3-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	Apartment			09/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	34.07172	-118.4648	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19484	19041-10000-36285	11845 W WICKS ST	91352	6	198B169   173	2631004023	M1-1-CUGU, P-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.23548	-118.39197	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19485	19041-20001-34925	12134 W VIEWCREST ROAD	91604	2	162B165   830	2369008017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM			PC Approved	10/08/2019 12:00:00 AM	ADDRESS	34.13883	-118.39714	$0 plan check fee due to SB1222 and AB1414supplemental plan check only, changes to approved set, clouded changes only. Relocation of 2 load centers and a relay to inside the garage	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19486	15041-10000-17773	1342 N FAIRFAX AVE 1-8	90046	4	147B177  1330	5551027004	R2-1XL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Apartment			06/09/2015 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.09565	-118.36135	SERVICE UPGRADE TO 600 AMPS FOR AN EXISTING APARTMENT BUILDING.  NEW SWITCHGEAR, ALL PANELS ARE EXISTING TO REMAIN.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19487	15041-10000-17963	2753 W WAVERLY DR BLDG 6	90039	4	151-5A207 233	5438025***	RD2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.10855	-118.26334	NEW DEVELOPMENT FOR MULTI BUILDING TOWNHOUSES 600 AMP SERVICE.  THIS IS BUILDING 1 OF 5.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL OUTDOOR ENERGY SQUARE FOOTAGE IN THIS APPLICATION ACCOUNTS FOR ALL FIVE BUILDINGS.  EACH BUILDING HAS ITS OWN SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19488	19041-10000-30229	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.05436	-118.25543	PLAN CHECK FOR TITLE 24 ONLY FOR CANOPY LIGHTING ONLY - TOTAL AFFECTED AREA = 8906 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19489	19041-30000-04267	9123 W CATTARAUGUS AVE	90034	5	123B169   323	4301003044	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.03559	-118.39162	Plan check for a PV1 roof-mounted PV system. System size is 5.48 kWac and consists of (10) micro-inverters, (20) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19490	10041-10000-23382	428 W FLORENCE AVE	90003	8	102B201   908	6020029014	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	33.97439	-118.28149	New service to supply new carwash structure, and existing panel at gas station conveniance store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19491	17041-20001-03164	8532 N HASKELL AVE	91343	12	192B141   155	2673011057	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM			PC Approved	02/13/2017 12:00:00 AM	ADDRESS	34.22566	-118.47624	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of roof-mounted solar pv system with DC battery back up.Interconnect with a 200A MSP. 6kW ungrounded pv inverter. 5kW DC battery. (19) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19492	15041-10000-06422	620 S UNION AVE	90017	1	132A205   143	5142028031	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.05638	-118.26929	INSTALLATION OF A FIRE PUMP IN A 3-STORIES COMMERCIAL BLDG; SERVICE CONDUCTOR S ROUTED OUTSIDE BUILDING TO ENTER BUILDING ON SERVICE  FP DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19493	10041-20000-14621	14006 W RIVERSIDE DR 122	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	Lighting in space 122. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19494	13041-10000-15734	4275 W 3RD ST	90004	10	135B193   198	5517008015	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM			PC Approved	06/14/2013 12:00:00 AM	PIN	34.06916588	-118.30753225	new tenant in vacant tenant spaceplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19495	15041-20000-43153	221 N FIGUEROA ST 13th flr	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.05882	-118.25099	Tenant improvements on  13th floor.  PC for Energy only, total area 17,272 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19496	14041-10000-35487	7340 N ETHEL AVE	91605	2	186B161   544	2327015008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.20416	-118.41802	Remove HID fixtures and replace with new LED fixtures as per DWP retrofit program.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19497	16041-10000-14560	25501 S BAYSIDE PL	90710	15	036B197  1106	7413025***	[Q]R3-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	33.79264	-118.29176	PV1 INSTALL 5.035 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(19) MODULES: SOLARCITY STANDARD (1) INVERTER: ABB OVI-3.6-OUTD-S-US-Z-A***plan is approved, but Jenny need verification from LA City (owner). RTI is issued.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19498	19041-10000-28268	4551 S GLENCOE AVE #152	90292	11	105B153   615	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	33.9844	-118.43407	ENERGY PC ONLY FOR  INTERIOR OFFICE REMODEL IN PORTION OF 1ST FLOOR: INCLUDES NEW OFFICES, NEW CONF ROOM, NEW BREAK AREA, NEW STORAGE ROOM, NEW CEILING,  AND FINSHES. ADD DEMISING WALL TO DIVIDE TENANT SPACE. AREA OF SCOPE 3,554SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19499	17041-20002-00778	635 W MCCARTHY WAY	90089	9	120A201    74	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	PIN	34.02171278	-118.2843696	6.5.2017 - Plan check for modifications to approved set. Remove building BSR from scope of project, update plans to reflect changes. Checking changes dated and clouded/delta'd after 2.13.2017. Update address in titleblock to reflect new address per parent express permit.======SUPPLEMENTAL PERMIT#17041-20000-00778 TO CHANGE THE ADDRESS FROM 941 W 35TH STREET TO 635 W MCCARTHY WAY.======Plan check for power only. Project site is the North Complex Residence Halls at USC. Project scope is a electrical infrastructure upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19500	15041-10000-22816	4200 N RADFORD AVE	91604	2	165B169   370	2368001028	[Q]MR2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	34.14736	-118.39192	INSTALLING NEW DISTRIBUTION BOARD TO POWER (2) SEWER GAS SCRUBBERS.  FULL PLAN CHECK FOR HAZARDOUS LOCATION CLASS 1 DIV 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19501	18041-10000-05659	15001 S FIGUEROA ST 2NF FL	90248	15	072B201    60	6120029009	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Issued	02/16/2018 12:00:00 AM	ADDRESS	33.89604	-118.28344	PER APPLICANT'S REQUEST, NEW 300A BUS PANELS IN 2ND FL SPACE OF A WAREHOUSE BUILDING. NO LOADS ARE ADDED .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19502	19041-10000-49875	5049 E YORK BLVD	90042	14	156A225   278	5476016018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	03/18/2020 12:00:00 AM		Permit Finaled	09/21/2020 12:00:00 AM	ADDRESS	34.12128	-118.20518	T-24 PLAN CHECK FOR A STORE TI. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 2001 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19503	14041-20001-11574	6623 W MELROSE AVE	90038	5	141B185   553	5524012022	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM			PC Approved	05/08/2015 12:00:00 AM	ADDRESS	34.08359	-118.33946	REVISE LIGHT FIXTURES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19504	18041-10000-38935	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR Tenant Improvement to existing retail space FOR T-24  ENERGY ONLY  ON GROUND FLOOR.SCOPE INCLUDES NEW CIRUCITS, LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 1421 SQ.FTB#18016-30000-32724	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19505	11041-10000-07334	1839 E 42ND ST	90058	9	114A215    77	5116027029	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.0061	-118.24032	T.I. OF BUILDING FROM A COLD STORAGE TO POULTRY PROCESSING BUILDING.  SERVICE UPGRADE, BRANCH CIRCUITS, AND EQUIPMENT LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19506	10041-20000-23028	20425 W SORRENTO LANE Building-15	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Apartment			11/18/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM				Plan check for new 3-story, 36 unit Apartment Building (Type A). Building 15. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19507	18041-10000-23390	1633 W 70TH ST	90047	8	102B193   921	6015027013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	33.97629	-118.30566	PC FOR ROOF MOUNTED PV ON SFD.  SCOPE INCLUDES 25 MODULES WITH OPTIMIZERS WITH SINGLE INVERTER (ESS ON SUPP. PERMIT 10002). SYSTEM SIZE 7.6KWAC/8.125KWDC AND 13.5 KWH ESS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19508	16041-20000-02245	4544 N CANOGA DR	91364	3	166-5A105 280	2190006020	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.14969	-118.60158	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. Standard plan in use.(24) Silevo Triex U290 Black Modules(1) ABB PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19509	16041-10000-40948	868 W MT WASHINGTON DR	90065	1	148-5A221 127	5464014034	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.10036	-118.22108	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PV1 HYBRID, INSTALL NEW 11.55 KW DC ROOF-MOUNTED SOLAR/WATER HEATING SYSTEM.(42) MODULES: SOLARWORLD SW275 MONO BLACK + COOLPV(42)MICROINVERTER: ENPHASE M250-6--2LL-S25NOTE :THE PV SYSTEM WILL BE USED TO HEAT WATER AND GENERATE ELECTRICITY FEEDING TO THE GRID.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19510	14041-20000-35843	6360 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Issued	02/02/2015 12:00:00 AM	ADDRESS	34.18619	-118.5972	T. I. TO (E) HILTON HOTEL - RELOCATE RESTAURANT/BAR, RELOCATE GIFT-SHOP; NEW RESTROOMS.  EXISITNG SERVICE, ADDING NEW TRANSFORMER, PANELS AND CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.  BUILDING SUBMITTAL DATE MARKED BEFORE JULY 1, 2014.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19511	18041-10000-42084	444 S FLOWER ST #4100	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLAN CHECK FOR TITLE 24 ONLY FOR - 7,660 SF NON-STRUCTURAL INTERIOR OFFICE TI.  WORK INCLUDING NEW DEMISING WALLS, NON BEARING PARTITIONS, CEILINGS, FINISHES & MILL WORK.  NO CHANGE OF USE. - TOTAL AFFECTED AREA = 7034 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19512	17041-20001-46487	23631 W COMMUNITY ST	91304	12	192B093   182	2005018016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	34.22182	-118.64214	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.5.2kW ungrounded pv system. (11) 325W pv modules. (1) 5kW Tesla Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19513	11041-10001-05924	15249 W VICTORY BLVD	91411	6	180B145   596	2235001022	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	ADDRESS	34.18686	-118.4657	CHANGES TO PERMITTED SET OF PLANS- ADDED LUMINAIRES ;REVISED THE LAYOUT OF A ROOM; ADDED RECEPTACLES New Chase bank. EPC is for power & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19514	15041-10001-22823	5422 W CARLIN ST #2	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/30/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19515	18041-20000-32198	539 N ALEXANDRIA AVE	90004	13	141B197   965	5520010023	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Apartment			08/23/2018 12:00:00 AM			PC Info Complete	10/16/2019 12:00:00 AM	ADDRESS	34.08025	-118.2982	600A 240/120V 3ph-4w service, power, and lighting for new building.  Building permit under 16010-30000-01976.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19516	19041-20000-37913	5913 1/4 W WILLOUGHBY AVE	90038	13	144B189   997	5534028016	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.08722	-118.32489	PV2. INSTALL 3.330 KW DC SOLAR SYSTEM WITH (9) MODULES AND OPTIMIZERS AND (1) INVERTER(SE3000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19517	11041-20000-24143	16623 W SHERMAN WAY	91406	6	183B137    41	2226006016	QC2-1VL, QP-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.20138	-118.49523	revise title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19518	17041-20000-07919	545 S FIGUEROA ST 1ST FLOOR	90071	14	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.0514	-118.2582	Plan check for energy only. TI to (E) barbershop and breakroom on main floor of private club. New lighting (incl. emergency). 838sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19519	12041-10002-24908	1111 W SUNSET BLVD	90012	1	136-5A211 440	5406020003	C2-2D	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			08/21/2013 12:00:00 AM			PC Approved	08/21/2013 12:00:00 AM	ADDRESS	34.06583	-118.24918	USING GU24 BASE LUMINAIRES ( LOCATED IN COMMOM AREAS) IN ACCORDANCE WITH SECTION 130 OF THE 2008 BUILDING ENERGY CODE; REVISED PHOTOMETRIC PLAN FOR EGRESS LIGHTINGRenovation of an existing 103 units appartment Bldg. EPC is for power & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19520	10041-10001-19874	2472 E 8TH ST	90021	14	123A219     1	5166001813	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Public Safety Only			02/10/2011 12:00:00 AM			PC Approved	02/10/2011 12:00:00 AM	ADDRESS	34.02945	-118.22736	Change the approved plan. Chnage the devices to water proof. EPC is for the changes. (((((((((((((Installation of a fire warning system in the Amtrak maintenance facility bldg))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19521	13041-10000-04394	7008 N OWENSMOUTH AVE	91303	3	183B105   637	2138008035	P-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2013 12:00:00 AM			Reviewed by Supervisor	03/12/2013 12:00:00 AM	ADDRESS	34.19762	-118.60139	PV2 Commercial solar installation. Plan check for new roof mounted 10KW photovoltaic system using two inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19522	15041-10000-09399	340 N AVENUE 53	90042	1	151-5A225 282	5469012001	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1835.20	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.11017	-118.20063	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19523	19041-10000-06440	445 S FIGUEROA ST 21st floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 21ST FLOOR FOR CORRIDORS AND RESTROOMS. TOTAL AFFECTED AREA IS 1968 SQ. FT. B#19016-20000-03716	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19524	16041-20000-33642	105 S DOHENY DR 1-35	90048	5	138B169   377	4335007123	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	05/21/2020 12:00:00 AM	ADDRESS	34.07503	-118.39011	Plan check for power and energy. Project site is a new 6-story apartment building (5 stories of residential over 1 story of parking garage) over 1 level of basement parking garage. Total lighting area = 8,013 sq. ft.Note: Building application has been generated under 15010-30000-01596	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19525	19041-20000-37066	11211 N SEPULVEDA BLVD lot #19	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 3.15 KW DC ROOF MOUNTED PV SYSTEM WITH (10) MODULES WITH OPTIMIZERS AND (1) INVERTER(SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19526	16041-10001-03326	5824 W 85TH PL	90045	11	096B169   484	4125006019	(T)(Q)RAS3-1	West Los Angeles	Westchester - Playa del Rey			2771.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Expired	03/14/2018 12:00:00 AM	ADDRESS	33.96029	-118.38318	02/12/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REPLACING THE INVERTER FROM AN ABB PVI-3.6 TO AN ABB PVI-3.0 AND REMOVING THREE KYOCERA 260W MODULES. TOTAL SYSTEM SIZE GOING FROM A 3.6KWac to 3.0KWdc. (((((((((PV1, NEW 4.19 KW DC/ 3.60 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MODULES: KYOCERA KU2606XPA(1) INVERTER: ABB PVI-3.6-OUTD-S-US-Z-A))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19527	10041-10000-08919	110 W 11TH ST	90015	9	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	05/12/2010 12:00:00 AM		Permit Expired	09/24/2012 12:00:00 AM	ADDRESS	34.0392	-118.25858	change of feeders conductors .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19528	17041-20001-14437	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	08/04/2017 Changes to an approved set of plans. All changes have been clouded and marked as Deltas 1, 2, and 5. Loads have been recircuited/relocated and there have been slight lighting changes.*****Previous Work Description*****Plan check for Power and energy wearhouse and office space T.I. new panels, lighting and receptacle. Total newly connected load exceed 400A feed from Existing 800A switch gear. Total area indoor lighting: 249,391 sq ft. B#17041-30000-04976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19529	15041-20000-14724	7045 N LURLINE AVE	91306	3	183B109   320	2137017016	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.19871	-118.58375	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19530	18041-10000-31843	1030 N SWARTHMORE AVE UNIT 2-113	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM			PC Info Complete	08/21/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Energy plan check for an outdoor dining area . Scope include new lighting and equipment with a total area of 1,230 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19531	17041-10000-00837	340 N HAWAIIAN AVE BLDG 9-LOT 7	90744	15	027B201   392	7417010908	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	33.77305	-118.27611	PC for a new fire alarm system. Scope includes 44 fire alarm devices and 2 fire alarm panels for an existing  apartment(Building 9, Lot 7).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19532	15041-20000-28029	1119 N BEVERLY GLEN BLVD	90077	5	144B153    47	4371017001	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.09497	-118.44082	Plan check for a PV1 roof-mounted Pv system. System size 3.8 kWac and consists of (1) inverter, (17) modules, and (17) power optimizers. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19533	19041-10000-29724	3235 W SAN FERNANDO ROAD Bldg 7A	90065	13	154-5A213 220	5458007016	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.11717	-118.24783	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19534	19041-10001-23950	222 W 109TH PL	90061	8	088-5A203 205	6074014034	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			PC Info Complete	12/30/2019 12:00:00 AM	ADDRESS	33.93642	-118.27705	Changes on Approved set. Adding a 100A subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19535	19041-20000-42335	3314 N APPLETON ST	90039	13	156A207   427	5435023027	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.12007	-118.26455	Plan check for PV roof mounted system, PV system size: 10.80KW DC, 9.78KW AC CEC with 30 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19536	17041-10000-20433	1511 E BAY ST	90021	14	123A215     3	5166032017	M3-1	Central				2060.10	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.03179	-118.23761	T24 TO REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19537	15041-20000-20874	19231 W VICTORY BLVD #150	91335	3	180B117   799	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	34.18678	-118.55214	Plan check for power and Title-24.  Total area = 2,774 sq. ft.  T.I. to existing medical Suite with 9 Exam rooms.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19538	13041-20002-31899	16407 W HAMLIN ST	91406	6	180B137   507	2231003028	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	ADDRESS	34.18854	-118.49054	Changes from previously approved plans.  Add DWP meter and a AC disconnect.Note: Plan check fee is $0.00 due to Senate Bill 1222 from 2012*****PV1.  Install 5.25 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverters: Enphase M215.  21 modules: Canadian Solar CS6P-250P*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19539	14041-20000-05892	2908 W 15TH ST	90006	10	126B193    40	5074010007	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.04523	-118.30635	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19540	14041-20000-33179	17500 W TUBA ST	91325	12	204B129   211	2734014001	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.25651	-118.51584	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. SYSTEM USES POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19541	11041-10000-15668	1717 W 6TH ST	90017	1	132A205    16	5153004013	C2-1	Central	Westlake	Westlake North		2089.02, 2089.04	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.05775	-118.27044	Change of use.  Lacation used to be a machanic shop and has now been converted to retail.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19542	14041-10000-05707	6547 W 83RD ST	90045	11	099B165  1101	4108009016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	33.96383	-118.40344	PV1, INSTALL 6.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(25) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19543	15041-10001-39605	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	33.94221	-118.40701	Change to approved set  (Delta 3).  PERMIT  SHALL BE PULLED UNDER MASTER.Energy plan check for a Kiosk T.I  (T4C-3301)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19544	14041-10000-03266	786 E 12TH ST	90021	14	123A211    93	5132012061	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.03227	-118.25087	T24 PART 6 ENERGY ONLY FOR 1092 SQ FT COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. REPLACING TOTAL OF (5) UNITS.  ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19545	17041-10000-43925	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			PC Info Complete	01/24/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR TITLE 24 ONLY. TI FOR EXISTING COMMERCIAL RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 980 SQ. FT. B#17016-10000-36181	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19546	15041-20002-28666	3150 W WILSHIRE BLVD # 200	90010	10	132B197   112	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.06163	-118.29086	changes to approved set of plans. include humidifier. changes clouded	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19547	11041-20000-08065	8976 N LAUREL CANYON BLVD	91352	6	195B165   167	2629019006	[T][Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.23276	-118.40423	compressed gas station new 800 A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19548	13041-10000-35507	6905 N TUJUNGA AVE	91605	2	183B173   184	2320002013	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.19629	-118.37921	NEW 3 STORY PARKING STRUCTURE PLAN CHECK. (E) SERVICE. PROJECTED AREA IN LIGHTING WORK IS APPROX. 101, 348 SQ FT (INDOOR + OUTDOOR ) .mAIN SWITCH BOARD WAS APPROVED UNDER  APPLICATION NUMBER 13041-10000-14444, breaker at parking structure is service rated breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19549	13041-10001-29570	9714 N ORCAS AVE	91040	7	201B173   350	2542023010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.24575	-118.36701	Expedited RSES plan check per applicant request.((((PV1.  Install 12.25 kW DC roof-mounted solar array, interconnect with main service panel.  Multiple inverters.  50 modules: Yingli Yl245p-29b.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19550	14041-20001-21914	10753 W ARMINTA ST	91352	2	189B177   402	2409007020	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM			PC Approved	08/20/2014 12:00:00 AM	ADDRESS	34.21384	-118.36538	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 11.4kW.(1) SolarEdge SE11400A-US transformerless inverter(54) Solar World Sunmodule SW250 Poly pv modules(54) SolarEdge P300 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19551	12041-20000-21423	17923 W CHATSWORTH ST	91344	12	207B129   356	2715025048	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.26507	-118.52442	T. I. RESTAURANT - 2853 SF W/710 SF Patio.  First Time Tenant, per applicant.  Full Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19552	15041-10000-13753	5340 S ALLA ROAD # 108	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	33.9773	-118.42567	PC FOR T24 ONLY. TI, NO CHANGE OF USE. OFFICE. TOTAL AREA 10619 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19553	17041-20000-32605	1654 W 11TH ST	90015	1	129A203   161	5137019006	C1-1-HPOZ	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.04836	-118.27686	Lighting for outdoor commercial parking lot.  Plan check for energy - 15,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19554	15041-10000-29021	3437 E PICO BLVD	90023	14	118-5A225 290	5190034005	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Closed	03/08/2023 12:00:00 AM	ADDRESS	34.01809	-118.20524	UPGRADE UNDERGROUND SERVICE TO 800A; LOADS REMAINING THE SAME	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19555	12041-10000-01407	4655 N NATOMA AVE	91364	3	168A111    94	2174015036	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.04, 1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2012 12:00:00 AM	02/29/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.15415	-118.57974	Plan check 17.28KW roof mounted photovoltaic system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19556	15041-20000-06232	700 W 9TH ST	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.04579	-118.2618	Power plan check only.  Provisions for electrical service from existing phase I highrise residential building (Apex I tower) to future phase II highrise residential building (Apex II tower).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19557	15041-10000-06525	6250 N TOPANGA CANYON BLVD BLDG F	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	NEW FIRE ALARM SYSTEM IN BUILDING F ON WESTFIELD PLAZA. 94 DEVICES AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19558	16041-10000-39482	1131 E 11TH ST	90021	14	123A213   106	5132007042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.03162	-118.24605	Title 24 plan check.  Remove HID fixtures and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19559	11041-10001-20685	1072-1076 E ELKGROVE AVE BLDG 21	90291	11	111B145   308	4243001037	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			05/30/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.00259	-118.45935	LINCOLN PLACE APARTMENT PROJECT.  ADDITION TO EXISTING ADDED 3  1920 VA  EVS  16 AMPS AT 125% 20 AMPS CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19560	14041-20001-29262	6800 N BALBOA BLVD D	91406	6	183B133   942	2225023019	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM			PC Approved	01/07/2015 12:00:00 AM	ADDRESS	34.19433	-118.50092	PC FOR T24 ENERGY ONLY. PERMIT ISSUED UNDER MASTER APPLICATION. THIS IS PLAN CHECK ONLY FOR REVISED LIGHITNG SYSTEM. DUE TO BUILDING SUBMITTAL, PLAN CHECK FOR 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19561	16041-10000-41406	3608 N BARHAM BLVD BLDG U	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.13836	-118.34154	PC FOR NEW PANELS, STACKED WASHERS & DRYERS IN CERTAIN APT. UNITS  IN BUILDING U OF CAMPUS STYLE COMPLEX. THIS IS BUILDING 6/6(Add 1 laundry ckt to 54 units, and 1 microwave ckt to all 108 units in the building, total 162 new ckt in the building.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19562	12041-10000-20574	2250 S BARRINGTON AVE	90064	11	123B149   488	4260013028	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Public Safety Only			08/30/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.0331	-118.44665	New Fire alarm system for PETCO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19563	10041-10001-12438	1000 E 7TH ST	90021	14	126A213   531	5146001001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Approved	04/12/2011 12:00:00 AM	ADDRESS	34.03846	-118.24391	Clouded modifications to original approved plans.  1) remove the emergency generator,  2) change the means of supplying emergency lighting in a low rise building, to unit equipment, 3)  revise the T-24 lighting forms, 4) revised circuit numbering to lighting circuits, 5) revise panel schedules for redistributed lighting circuits and loads.  No new permit issued, see existing permit 10041-10000-12438.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19564	11041-10000-10414												Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM			PC Approved	01/13/2011 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19565	12041-10002-06759	10377 W MCBROOM ST	91040	7	207B177   104	2528031014	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	34.26281	-118.35664	Revision to the approved plan. Change the location of INV and run the conduit through crawl space. (((((((((((((((((((((NEW ROOF MOUNTED 9.6KW PV SYSTEM ON A SINGLE FAMILY HOUSE USING TRANSFORMERLESS INVERTERS.  PANEL/SERVICE UPGRADE ARE NOT A PART OF PLAN CHECK.  PLAN CHECK ONLY FOR PHOTOVOLTAIC PORTION.))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19566	13041-10001-17994	418 S SPRING ST	90013	14	129A211   276	5149038***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.04834	-118.2485	((10/29/2014 - Sup. application for changes to approved set.  Plan check for power and title 24.  Changes to air conditioning and transformer ratings and interconnections.  Equipment will no longer be series rated.  Changes to lighting throughout the building))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19567	19041-20000-12659	15693 W OLDEN ST	91342	7	225B141    39	2603019011	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Issued	11/02/2020 12:00:00 AM	ADDRESS	34.31724	-118.47345	PV1.  Install 15.37 kW DC / 13.6 kW AC roof mounted grid tied PV system.  (53) modules with 6 and 7.6 kW rated string inverters.  Main service disconnect derate to 150A.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19568	13041-20000-03472	17242 W WARRINGTON DR	91344	12	216B133    65	2606008022	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.29215	-118.51042	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19569	17041-10000-40926	10617 N TAMARACK AVE	91331	7	207B157   817	2620007015	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.26283	-118.42327	PC FOR 5KW ROOFTOP PV. INSTALLING 24 MODULES WITH OPTEMIZERS AND ONE CENTRAL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19570	15041-20000-24574	5719 N NOBLE AVE	91411	4	174B145   274	2243007027	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.17451	-118.46199	Plan check for a PV1 roof-mounted PV system. System size is 6.9 kWac and consists of (32) modules, (32) micro-inverters, and (1) solar load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19571	14041-10000-21310	9822 N INDEPENDENCE AVE	91311	12	201B109   139	2746002007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.24886	-118.5906	Remove HID light fixtures and replace with new fluorescent fixtures. T24 plan check. Area = 7520 sq. ft. 10 units	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19572	17041-20001-34457	14323 W JOY DR	91331	6	198B153  1031	2644027243	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.2416	-118.44535	Changes to an approved set of plans. Equipment ratings have changed and PV system size is now 3.8 kWac.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19573	19041-20000-45915	414 N CRESCENT HEIGHTS BLVD	90048	5	141B177  1443	5514006037	R1V3	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.07866	-118.36571	Plan check for PV roof mounted system, PV system size: 10.23KW with 31 PV Modules and 31 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19574	11041-20000-27391	16020 W BASSETT ST	91406	6	183B141   622	2224027015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.19598	-118.48209	PV system 13.7 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19575	18041-10001-21967	1371 S WESTWOOD BLVD	90024	5	132B153   810	4324009009	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.0557	-118.44223	TI IN AN EXISTING RESTUARANT (DOMINO'S PIZZA). T-24 ENERGY ONLY.PERMIT WAS ISSUED UNDER 18041-10000-21967.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19576	16041-20000-22891	17928 W RAYMER ST	91325	12	195B129   559	2787035053	R1-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.22705	-118.5241	Plan check for PV roof mounted system. System size: 5.0kW with 22 modules and 1 inverter(5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19577	12041-20000-25512	2400 N LAKE VIEW AVE	90039	13	148-5A209 412	5440021004	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.10004	-118.25423	Plan check for PV system. Roof-mounted single family dwelling. Transformerless inverter. 5.635kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19578	15041-20001-39347	10556 W CANTARA ST	91352	2	192B177  1002	2407008029	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM			PC Approved	11/30/2015 12:00:00 AM	ADDRESS	34.21885	-118.36155	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (14) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19579	12041-10000-20978	3800 N HOMER ST	90031	1	144A223   668	5207006900	[Q]OS-1XLD-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1994.00	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM	09/05/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.08842	-118.20786	Plan check for new installation of fire sprinkler monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19580	14041-10001-04955	7712 S TOLAND AVE	90045	11	099B173   332	4127015009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	33.96767	-118.37652	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON  A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19581	10041-20000-02474	5340 S ALLA ROAD 2ND FL	90066	11	102B157    39	4211008023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM			PC Approved	02/12/2010 12:00:00 AM	ADDRESS	33.9773	-118.42567	TENANT IMPROVEMENTS FOR STAMPS.COM   OFFICE  T.I. Title 24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19582	13041-20000-08589	5401 W WILSHIRE BLVD 2nd floor	90036	4	135B181   907	5508009001	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.06244	-118.34639	T24 lighting plan check for a remodel of the second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19583	17041-10000-03891	5319 N VAN NUYS BLVD	91401	4	172-5A151  95	2249005001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.1673	-118.44893	Plan check for Title 24 only in existing space, remove outdoor HID fixtures and replace with new LED lighting fixtures. Total area: 24,225 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19584	19041-20000-42239	2221 W WASHINGTON BLVD	90018	10	126B193   883	5073013002	C2-2D-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	08/31/2020 12:00:00 AM		Permit Finaled	03/16/2022 12:00:00 AM	ADDRESS	34.0401	-118.30964	New distribution panels, power, and lighting for (E) building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19585	14041-10001-35712	14823 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	34.17768	-118.45525	ploan check only added nuetral to feeder ac panel. Plans approved in Van Nuys per E.M.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19586	18041-10002-44175	811 W 7TH ST	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM			PC Approved	04/25/2019 12:00:00 AM	ADDRESS	34.04908	-118.25911	Change to approved set by adding new lighting on the floor plan. All changes under delta-10 only.(((PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 7773 SQFT AREA.BUILDING # 18016-10000-37209)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19587	17041-10000-43169	19240 W BALLINGER ST	91324	12	201B117   680	2762011006	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.24333	-118.55309	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.70KWdc / 7.60KWac. (30)MODULES-SOLARWORLD 290 (30)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE 7600H(240)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19588	13041-20000-13326	5990 N SEPULVEDA BLVD Suite 100	91411	4	177B145   487	2243019023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	ADDRESS	34.17911	-118.46588	T24 FOR EXISTING HIGH RISE OFFICE BUILDING. 3757 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19589	15041-10000-08813	401 W 5TH ST 1ST FLOOR	90013	14	129A211   288	5149028015	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.04899	-118.25187	TI TO EXISTING RETAIL SPACE TO CHANGE THE USE TO A COFFEE SHOP.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19590	16041-10000-40025	5800 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PLAN CHECK FOR TITLE 24 ONLY.  1ST FLOOR BATHROOM REMODEL<<STAGE #7 & #8>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19591	19041-20000-49408	18747 W WELLS DR	91356	3	171B121   411	2161012012	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.16329	-118.54081	Plan check for PV roor mounted system, PV system size: 6.6KW DC, 5.911KW AC with 44 PV Module and 44 microinverters.Fees $56.29 due to California Senate Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19592	19041-30000-52604	601 S FIGUEROA ST P1 LVL-Valet	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	03/09/2020 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.05076	-118.25881	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING, POWER, AND CIRCUITS. TOTAL AFFECTED AREA IS 1525 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19593	17041-20000-29083	5245 N LANKERSHIM BLVD	91601	2	171B173   439	2350017034	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.16601	-118.37573	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from restaurant to ice cream shop/tenant improvement. Total lighting area = 1,375 sq. ft.Note: Building permit has been pulled under 17016-30000-19807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19594	10041-10000-02489	3300 S CENTRAL AVE	90011	9	117A209   329	5114026014	(T)(Q)C2-1L	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	04/21/2010 12:00:00 AM				First time tenant for Sub Way.  Previously plan check under 09041-10000-11644.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19595	18041-10001-08398	10900 W WILSHIRE BLVD 7TH FLR	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	DELTA 6 CHANGES TO APPROVED PLANS.TI IN AN EXISTING OFFICE AREA. (13,292 SF) Plan Check is for T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19596	14041-20000-10527	17022 W HARTSOOK ST	91316	5	171B133   447	2258023030	RE9-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.16395	-118.50412	PV1 SINGLE FAMILY DWELLLING. TOTAL SYSTEM SIZE 7KW AC USING 3 STRINGS. 21 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19597	13041-10000-27232	11225 N LOUISE AVE	91344	12	210B133   220	2711009005	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.27457	-118.51119	"PV1 8.25KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: SOLAREDGE SE3000A-US and SOLAREDGE SE5000A-US] [( 33) MOD: renesola JC250M-24/BB].""Expedited plan check per applicant request""."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19598	15041-10000-22987	20131 W PRAIRIE ST	91311	12	198B113   121	2748038033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.2394	-118.57264	NEW FIRE ALARM SYSTEM 1- FIRE ALARM PANEL, 1- COMMUNICATION PANEL, 3-CONTROL PANEL AND 174 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19599	19041-20000-51580	3276 S STONER AVE	90066	11	117B153   502	4250006011	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	05/26/2020 12:00:00 AM	ADDRESS	34.01757	-118.43543	Plan check for Energy Storage system installed into existing PV System, Energy Storage System size: 13.2KWh(Tesla Power Wall), sub-panel and Energy Gateway.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19600	13041-10001-15910	928 S WESTERN AVE 225 & 226	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.05485	-118.30886	Retail TI for suites 225 and 226 for jewelry store in a 3-story shopping center.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19601	16041-20000-00583	11963 W COLLINS ST	91607	2	174B165   473	2340031019	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.17393	-118.39417	Plan check for PV roof mounted system. System size: 5kW with 20 modules and 20 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19602	16041-10000-37852	14200 W ARMINTA ST	91402	6	189B153   990	2212001017	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.21268	-118.44283	PC FOR POWER, PROPOSED NEW COOLER ADDITION TO THE EXISTING SINGLE LINE DIAGRAM. CONNECTED TO 1000A  480V 3 PHASE 3 WIRE SWITHCHGEAR. ( PER NABIL)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19603	15041-20000-25554	5256 W WASHINGTON BLVD	90016	10	126B177   900	5063001034	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.04111	-118.35596	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total indoor lighting area = 9,790 sq. ft. Total outdoor lighting area = 550 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19604	14041-20001-13932	8711 N CORBIN AVE	91324	12	195B117   211	2782022019	C2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.22864	-118.56246	Plan check for modifications to approved set. Update plan to address inspector corrections: show correct wall switch locations, show emergency buglights, correct light fixture locations and counts to reflect actual installation.[PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. YOUGURT AND JUICE BAR. NEWLY CONNECTED LOAD < 400 AMPS. 1378 SQFT, EMERGENCY LIGHTING.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19605	11041-20000-07523	5911 W HOLLYWOOD BLVD	90028	13	148-5A191 145	5545003016	C4-1-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.10183	-118.31846	TI restaurant.  title 24 only.  repalcing three panels and circuits.  no addition of load	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19606	17041-20000-13600	9366 W FLICKER WAY	90069	4	147B165   556	4392006017	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2017 12:00:00 AM			PC Info Complete	06/13/2017 12:00:00 AM	ADDRESS	34.09571	-118.39353	Main house served with (N) 1000a, 120/208v, 3ph disrtribution panel fed from (E) 1200a main electrical service located at (E) villas.building permit# 15010-20000-02157	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19607	10041-10000-24070	6320 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.18499	-118.59722	T-24 and elective plan check for new electrical systems.  T-24 plan check is for alteration to an existing lighting system, no new lighting istalled.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19608	12041-20000-00985	15060 W VENTURA BLVD #240	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Info Complete	01/17/2012 12:00:00 AM	ADDRESS	34.15287	-118.46147	T.I. to existing building building.  Install general/emergency lighting in offices, reception, conference, and hallway areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19609	14041-20000-25246	5950 W FOREST LAWN DR	90068	4	165B189    11	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.1522	-118.31832	TI TO ANEXISTING COMMERCIAL ONE STORY BUILDING.  ADDING LIGHING USING EXISTING POWER EQUIPMENT.  1349SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19610	19041-20000-03744	8741 W 3RD ST	90048	5	138B169   501	4334005012	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.07372	-118.38308	Plan check for Title 24 only in existing space change to use from retail to take out restaurant. Total area: 408 sq ft. B#19016-20000-00797	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19611	13041-10000-34475	6256 N TOPANGA CANYON BLVD BLD # C&D	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	07/18/2014 12:00:00 AM		Issued	07/18/2014 12:00:00 AM	ADDRESS	34.18496	-118.6049	PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING C AND D.BUILDING PERMIT # 13010-10000-02906.New 2 STORY retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19612	13041-20000-22821	6868 W GRENOBLE ST PV-1	91042	7	207B201   215	2553011020	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.26146	-118.28103	PV-1. Power optimizers. 3kW Inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19613	18041-10000-24712	991 W KNOX ST	90502	15	057B197    17	7351031018	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.85434	-118.29386	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19614	16041-10000-32847	6835 W VALMONT ST	91042	7	204B201  1095	2565019042	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.25189	-118.28068	PV1 roof mounted solar system installation to a single family dwelling. Installing a central inverter rated at 3.0 kWac and 13 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19615	14041-20000-34975	23018 W HARTLAND ST	91307	12	183B097   788	2026010004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.19445	-118.62907	PV1. ROOFMOUNTED. SYSTEM SIZE: 8.925 KW.(35) KYOCERA KU2556XCA MODULES(1) ABB PVI 3.0(1) ABB PVI 4.2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19616	16041-10000-00371	14006 W RIVERSIDE DR #204	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Master permit is for plan check only. Plan was required to resubmitted for a full plan check. Permit will be pulled under the supplemental application : 16041-10001-00371(((T-24, TI TO AN RETIAL SPACE INSIDE A MALL. SCOPE OF WORK INCLUDES NEW PANELS, LIGHTS AND RECEPTACLES. . TOTAL SQ. FT. 9545. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19617	19041-20000-02293	9110 N DE SOTO AVE	91311	12	198B109   171	2748037028	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	34.2358	-118.58833	New 4-story self-storage building.  800A 480Y/277V 3ph-4w service.  81,725 sq ft.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19618	19041-20000-30957	801 S FIGUEROA ST SUITE 2025	90017	14	129A207   153	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM			PC Info Complete	08/08/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Tilte 24 Energy for existing office Tenant Improvement Total area: 2965 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19619	17041-10000-01048	435 W BERNARD ST 1-9	90012	1	136-5A215 132	5414017028	C2-2D	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.06732	-118.23693	FULL PC FOR POWER AND ENERGY FOR A NEW MIXED USE 3 STORY BUILDING OVER A BASEMENT GARAGE(RETAIL SPACE AND 9 UNIT APARTMENT BUILDING). SCOPE INCLUDES TWO NEW SERVICES (800A AND 200A 120/240V), NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. THERE ARE 7 DIFFERENT TYPES OF UNIT PANELS FOR ALL UNITS. TOTAL AFFECTED AREA IS 8025 SQ. FT. B#13010-10000-04576	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19620	17041-20000-02860	15301 W VENTURA BLVD p37	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.15411	-118.46654	ti to an existing commercial space.  adding new lighting new controls to existign panels.  plan check for energy only.  total square footage 186.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19621	14041-20000-20258	807 N ARBOL ST	90065	1	151-5A221 113	5471005010	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.11041	-118.21601	New roof mounted PV system with Enphase model M250-60-2LL.  Total system size 4.3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19622	18041-10002-13043	18607 W HILLSBORO ROAD	91326	12	207B121   803	2728030001	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Issued	07/23/2018 12:00:00 AM	ADDRESS	34.26038	-118.54053	NOTE: FEES ARE $0 DUE TO DEPARTMENTAL ERROR. CHANGES WORK DESCRIPTION FOR PV SYSTEM SIZE. TOTAL SYSTEM SIZE IS 10.85KWdc / 9.57 ACcec.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19623	15041-10000-35485	1360 S FIGUEROA ST 1st Floor	90015	14	126A205    58	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	10/05/2016 12:00:00 AM		Issued	10/05/2016 12:00:00 AM	ADDRESS	34.03896	-118.26891	Full PC, First time tenant restaurant,  to an existing core/shell building. Scope of work includes new lighting and receptacles.  Sq.Ft. 6552.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19624	19041-20001-34478	3700 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	10/23/2020 12:00:00 AM	ADDRESS	34.14064	-118.34139	PV2.  Install 138.6 kW AC / 170.52 kW DC roof mounted grid tied PV system.  (392) modules with (9) 9 kW and (4) 14.4 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19625	19041-10000-02791	6161 W PICO BLVD	90035	5	129B173    23	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.05339	-118.37556	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19626	11041-20000-05323	1111 W WILSHIRE BLVD	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			03/17/2011 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.05259	-118.26348	Plan check power and energy for 7-story 210 units mixed-used apartment building (low rise building). Two 3000A services supplying building. Modification to seperate fire alarm system submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19627	17041-20000-21579	2201 N BEVERLY DR	90210	4	150B157    32	4386016024	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Expired	12/27/2021 12:00:00 AM	ADDRESS	34.11039	-118.41907	Plan check for power only. Replacing overhead 600A service with underground 600A service. New 600A switcboard and distribution panel, refeed existing 400A and 200A distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19628	15041-20000-05478	23525 W BURBANK BLVD	91367	3	174B093   317	2041010041	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.17205	-118.63922	Installation of new central inverter roof mounted solar PV array.  Total system size = 9.995 kWac (1 inverter connected to 4 strings with 10 modules each)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19629	19041-20000-23757	9413 N BURNET AVE	91343	7	198B145   442	2656019***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.24126	-118.46341	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 11.1KW DC/9 KW AC. SCOPE OF WORK INCLUDES (37) LONGI PV MODULES AND A NINGBO GINLONG SOLIS-1P9K INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19630	16041-20000-09449	14319 W ADDISON ST	91423	4	171B153   730	2248008035	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			03/17/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.16175	-118.44496	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19631	17041-20000-43539	11801 S TEALE ST	90230	11	105B165   288	4220006077	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	33.98562	-118.40102	Plan check for energy only. TI to  (e) office. New lighting (incl. emergency) - indoor=3,865sqft; outdoor=934sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19632	14041-20000-08410	18148 W SANDRINGHAM CT	91326	12	213B125   310	2870015025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.28069	-118.53028	Roof mounted PV system with 7.5KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19633	15041-10000-16009	10455 W MAGNOLIA BLVD 1-26	91601	4	171B177   636	2417017026	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.16508	-118.35903	PV2 INSTALLING PV SYSTEM ROOF MOUNTED.  52 MODULES AND 1 INVERTER. TOTAL SIZE 11.67KW .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19634	10041-10000-12573	425 S PALOS VERDES ST 5th Floor	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Issued	10/27/2010 12:00:00 AM	ADDRESS	33.74102	-118.28156	OFFICE T.I. AT PORTION OF THE 5TH FLOOR.  ADD/RELOCATE OFFICE PARTITIONS AND LIGHT FIXTURES. plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19635	19041-20000-42308	20159 W HATTERAS ST	91367	3	174B113   127	2151008058	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.17582	-118.57294	Plan check for PV roof mounted system, PV system size: 13.33 KW DC, 11.4KW AC with 43 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19636	11041-20000-08184	2029 S CENTURY PARK EAST #4100	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	08/30/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to existing high rise building of 41st floor.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19637	15041-30000-42270	11529 N COLLETT AVE	91344	12	213B141    99	2605020026	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Closed	01/22/2016 12:00:00 AM	ADDRESS	34.28015	-118.48444	Addition of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19638	18041-20001-04018	926 N NORDICA DR	90065	1	153A221   316	5475017025	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.11284	-118.22039	3/12/2018changes to an approved set of plans.  changes to include addition of (2) AC disconnects.  changes are noted delta B only.  (((PV1.  Install 3.9 kW PV system.  (12) modules with 3.8 kW rated string inverter.  27 kWh energy storage system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19639	14041-10000-14969	10612 W NATIONAL BLVD	90034	5	123B161   849	4314026053	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.03064	-118.41583	New coffee shop with 208Y/120V 400A service, plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19640	18041-20000-17141	11937 N RICASOLI WAY	91326	12	216B109   332	2701085013	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Re-Activate Permit	04/17/2019 12:00:00 AM	ADDRESS	34.28986	-118.58501	pv1install roof mounted pv system sized 12.6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19641	14041-20000-09396	10363 N MARKLEIN AVE	91345	7	204B145   174	2649015008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.25867	-118.47043	PV1.  Install 4.9 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.  20 modules: Trina Solar TSM245.  PowerOne PVI-5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19642	15041-10001-41756	380 WORLD WAY T08	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM			PC Info Complete	03/14/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE TO LIGHITNG CONTROLS. CHANGE TO UNIT EQUIPMENT. CHANGE SUBPANEL TO 600A BUS. MINOR RELOCATION OF LOADS AND 1 NEW CIRCUIT. ALL CHANGES NOTED DELTA 2 AND 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19643	10041-20000-21394	7800 W WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2780.00	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	10/28/2010 12:00:00 AM		Permit Closed	11/19/2010 12:00:00 AM	PIN	33.93790872	-118.42837934	Plan check for new installation of 1200A switch supplying temporary portable crusher at LAX. Existing service and exisiting underground run to supply switch equipment in methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19644	15041-10000-28202	4484 W WILSHIRE BLVD	90010	4	132B185    46	5090019080	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.06174	-118.3269	PC for energy only, T-24 to an exisiting commercial bldg (Mercury Casualty Co.) Scope of work: changing light fixtures from fluorescent to led and high voltage controllers to low voltage occupancy sensors. sq ft = 43,200.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19645	16041-20000-08963	5410 N RHODES AVE	91607	2	171B165    39	2347006***	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			Corrections Issued	04/05/2016 12:00:00 AM	ADDRESS	34.16912	-118.40293	Install a roof-mounted solar array on a commercial building. Interconnect with a 400A MSP.System size: 20kW (10+10). Ungrounded system. (63) 265W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19646	17041-20001-11725	6600 N TOPANGA CANYON BLVD 84b	91303	3	180B101   822	2139004044	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Approved	07/07/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Revisions to approved set.  Minor additions to lighting system, SLD/power changes not related to Title 24 Part 6 review.  Delta-3 revisions only.  (((TI to an existing commercial space in Westfield Mall.  Plan check for energy only.  Total square footage 5346.  Plan check for energy only.Express permit issued under 17041-10000-19114)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19647	17041-20000-14009	22630 W MACFARLANE DR	91364	3	171B097   833	2075022003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.16281	-118.61935	permit fee $0.00 by state senate bill no.1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19648	19041-10000-29424	4344 S DEGNAN BLVD	90008	10	114B185  1143	5024019008	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.00483	-118.33125	EXTERIOR LIGHTING ON BUILDING FOR WALKWAY PLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19649	19041-10000-04762	433 E 7TH ST	90014	14	127-5A213 561	5148024013	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.04136	-118.24749	PLAN CHECK  ONLY. T-24 Change of use to retail space to a take-out restaurant, and related T.I.; Scope of work includes new lighting and recptacles. total sq. ft. 861. Inspection Fees have been paid for under App# 16041-10000-34079 / X16LA15626	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19650	19041-20000-13864	3022 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	08/02/2022 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19651	18041-30000-28694	19821 W RINALDI ST Ste. 100	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Issued	11/19/2018 12:00:00 AM	ADDRESS	34.27548	-118.56626	Full plan check, Change of use to a Restaurant with over 100 occupancy load. (2) new panelboards, (1) new 112.5 kVA TX. New lightings and power fed from (E) 800A switchboard. Total area: 2,372 sq.ft, T24 using performance method.*See application comment)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19652	11041-10000-16198	23703 W VANOWEN ST	91307	12	180B093    17	2034032072	[Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/05/2011 12:00:00 AM	ADDRESS	34.19343	-118.64283	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19653	17041-10000-38004	189 S THE GROVE DR suite H-4	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	Fire alarm system plan check for 2 story building. installing 50 devices, 1 facp, 1 annunciator and 1 power supply panel. This plan check is for Phase I of project (Phase II and III will add more devices to FACP).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19654	16041-10002-15025	737 N PARKMAN AVE	90026	1	130-5A201 147	5136015030	C2-1, C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM			PC Approved	08/29/2016 12:00:00 AM	ADDRESS	34.07998	-118.27534	08/29/16Changes to an approved set of plans. Changes include derating the main breaker from 100A to 90A, and providing load calculation for service.  Note: Permit is paid under PCIS#16041-10000-15025(((((((PV1 5KW DC ROOF MOUNTED SOLAR ARRAY, SINGLE FAMILY. 20 MODULES ( RENOGY 250) WITH 20 MICRO INVERTERS ( ENPHASE M250-60-2LL-S22).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19655	16041-20000-08389	22738-22740 W VENTURA BLVD	91364	3	171B097   405	2040031045	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM			PC Approved	03/09/2016 12:00:00 AM	ADDRESS	34.16622	-118.62188	Plan check for energy only. Commercial fire repair for damaged retail space. All electrical inside unit 22740 is new (including lighting). 788sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19656	15041-20001-40700	10801 N WINNETKA AVE	91311	12	207B113    70	2707003036	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM			PC Approved	12/28/2015 12:00:00 AM	ADDRESS	34.26556	-118.5712	Expedited RSES plan check per applicant request.  (((PV1.  Install 9.24 kW roof-mounted utility-interactive PV system.  (33) SolarWorld 280W with (1) Fronius-IG Plus A 10.0 central inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19657	17041-20000-30647	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	2500 amp bus buct for temp power (construction site).  plan check for power.  No loads, all loads to be future under separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19658	14041-20000-29183	10204 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.25583	-118.57964	Plan check for power only. New 600A service tapping off of existing 1200A service pull section. New panels and equipment only, no loads to be installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19659	18041-20001-22212	2660 N ANGELO DR Rest Room	90077	5	153B153     3	4382029***	A1-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	34.11964	-118.44259	06/19/2018 Changes to an approved set of plans. Changes have been made on the lighting floor plans. All changes have been reflected onto the Title 24 compliance forms. *****Previous Work Description*****Plan check for Title 24 Energy only in existing restroom and existing community fitness center. Total area: 953 sq ft. B#17016-30000-32186	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19660	18041-20000-34307	4467 N WOODLEY AVE	91436	5	168B137   787	2284006059	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.15286	-118.48486	new SFD 600 amp service.  Plan check for power only.  permit fees under building combo permit 15010-20000-03590	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19661	18041-20001-17860	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.15713	-118.43792	"07-31-2019 Changes to an approved set of plan, changes include update approved drawing and title 24 in electrical room. All Changes has been clouded as delta  ""1"" only"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19662	13041-20000-20188	5155 N KELVIN AVE PV-1	91364	3	171B109   190	2166031006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.16413	-118.58497	PV-1. Plan check for microinverters. 8.835kW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19663	17041-10000-01145	3219 N ANDRITA ST	90065	13	154-5A213  99	5458016023	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.11813	-118.24371	PLAN CHECK FOR ROOF-TOP MOUNTED SYSTEM INSTALLED IN A EXISTING DUPLEX(3 UNITS-COMMERCIAL). SYSTEM CONSIST OF CENTRAL INVERTER(PVI-3.0) 3KVA, WITH 11 MODULES(LG NEON 2).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19664	14041-20001-04061	11944 N SIERRA LANE	91326	12	216B121   240	2872004022	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			Reviewed by Supervisor	03/04/2014 12:00:00 AM	ADDRESS	34.28945	-118.55078	][][ EXPEDITED PER APPLICANT REQUEST ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 225 MAIN SERVICE PNL. TRANSFORMERLESS SYSTEM, SIZED @ 8.5 kW DC, WITH (34) TRINA SOLAR TSM-250W MODULES, (34) SOLAREDGE OPTIMIZERS OP300-MV, (2) SOLAREDGE INVERTERS, SE5000-US-ZB-U, SOLAREDGE SE3000A,-US-ZB-U, (1) 125A LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19665	16041-10000-37244	11666 W BURBANK BLVD	91601	2	174B169   918	2350001018	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.17194	-118.38684	PC for energy only to existing retail store (7eleven store) Including lighting and power only. Total sqft = 1754.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19666	19041-10002-04485	3030 W OLYMPIC BLVD SUITE #113	90006	10	129B193   316	5080033029	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.0524	-118.3013	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY CHANGES INCLUDES ADDING NEW LIGHTING FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19667	18041-10001-28132	1030 N SWARTHMORE AVE #3-107	90272	11	129B125   834	4423016008	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS UNDER DELTA 2 - CHANGES INCLUDE ADDING NEW INVERTER FOR EMERGENCY LIGHTINGPLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19668	16041-10001-37768	500 E WATER ST PV	90744	15	027B209   227	7440010910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	33.76653	-118.25893	EXPEDITED PER APPLICANT REQUEST ************************************************************************************PC FOR PV SYSTEM FEED IN TARRIF (FIT). SYSTEM SIZE IS 1085KW.DC APPROX. 860KW.ACSYSTEM INCLUDE 3192 MODULES AND 11 INVERTERS (50KVA)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19669	13041-20000-24853	18454 W OXNARD ST	91356	3	177B125   704	2157001152	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.17982	-118.53526	Change to lighting only.  Existing commercial retail space.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19670	19041-20000-06839	9333 S LINCOLN BLVD PV1	90045	11	096B161   838	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	08/29/2020 12:00:00 AM	ADDRESS	33.95576	-118.41559	PV2.  Install 122.64 kW DC / 112.06 kW AC roof mounted grid tied PV system.  (336) modules with (4) 33.3 kW rated string inverters.  System 3 of 4.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19671	16041-10000-06703	600 W WILSHIRE BLVD STE 100	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.04796	-118.25622	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM BANK TO RESTAURANT; NEW KARL STRAUSS BREWERY/RESTAURANT IN VACANT FIRST FLOOR TENANT SPACE; NEW COMMERCIAL KITCHEN, AND BREWERY ADDITION. SCOPE INCLUDES NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. NEW CONNECTED LOAD >400A. TOTAL AFFECTED AREA IS 11960 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19672	13041-10001-30390	2252 N TRACY TER	90027	4	148-5A205 160	5433017006	[Q]C1-1XL	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	34.10205	-118.2735	Expedited RSES plan check per applicant request.PV1, Install 5.04 kW DC roof-mounted solar array for a residential house, interconnect with main service panel. 21 microinverter, 21 modules. non std plan. 400 amp service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19673	15041-10000-01077	12558 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	33.97812	-118.41195	Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19674	13041-20000-18837	1724 W 24TH ST	90018	8	123B193   392	5058028005	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Apartment			07/17/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	34.03436	-118.30104	PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 4.3 KW USING ENPHASE MICROINVERTER. NONSTANDARD PLAN. 20 MODULES TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19675	12041-10000-10133	709 S MANHATTAN PL 1-10	90005	10	132B193   350	5093004016	R4-2	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	Apartment			05/03/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.05928	-118.31042	5 stories apartment, 106 devices and two panels fire alarm .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19676	15041-10000-29173	17147 W OROZCO ST	91344	12	222B133   138	2602006014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.30678	-118.50554	PV1 INSTALL 6.84 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(24) MODULES: SOLAR WORLD SW 285 MONO(24) MICRO INVETER: ENPHASE ENERGY M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19677	18041-10000-09710	624 S GRAND AVE	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			Corrections Issued	03/24/2018 12:00:00 AM	ADDRESS	34.04802	-118.25572	INSTALLATION OF DC POWER SYSTEM CABINET ON THE 7TH FLOOR FOR A DATA CENTER. DC CABINETS  ARE SUPPLIED FROM generator bus and nonlegally required bus on the 11th floor to panelboards through ATS switch.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19678	14041-10000-11748	3131 S ALAMEDA ST	90058	9	115-5A215  12	5117017015	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.01074	-118.23993	CHANGE OF USE FROM WAREHOUSE TO OFFICE. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19679	13041-10000-00561	11716 N HUNNEWELL AVE	91342	7	213B165   152	2531032041	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1042.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	34.28333	-118.39959	PV1:  Applicant is using the ENPHASE M215 microinverter to install a new 3.672 KW roof mounted PV system.  Applicant is using the standard plan.  Installing 17 REC 245 PE modules and 17 microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19680	11041-20001-25059	1625 N SCHRADER BLVD 3rd Floor	90028	13	148-5A187 241	5547015029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.10046	-118.33259	Changes to approved set of plans. Moved some partitions. Miscellaneous permit per inspector's request. As built drawings. T.I. to an existing Medical Office includes new exam rooms and reconfiguring blood drawing nurse stations or 3rd Floor. Plan check for power and  energy. New panel and branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19681	14041-10000-02162	400 S WESTERN AVE #100	90020	10	135B193   439	5503014023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.067	-118.30888	Tenant improvement for commercial retail space.  Title 24 plan check for changes to existing lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19682	17041-10003-03201	1942 S POINT VIEW ST	90034	10	126B173   749	5066016025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM			PC Approved	05/10/2017 12:00:00 AM	ADDRESS	34.04073	-118.37336	CHANGES TO APPROVED SET OF PLANS. CHANGED SHOWN ON PLAN R4. MADE LOAD SIDE TAP. APROVAL SUBJECT TO UL RECERTIFICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19683	16041-30000-31139	1103 S BOYLE AVE	90023	14	123A219   118	5170008022		East Los Angeles	BOYLE HEIGHTS			2060.50	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.03162	-118.2203	Plan check Title 24 only in existing space T.I., remove outdoor lighting fixtures and replace with new LED lighting fixtures. Total area: 36,550 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19684	15041-10001-37762	5715-5717 N FIGUEROA ST	90042	1	151-5A229 170	5492001015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.10994	-118.19246	02/16/2017 Changes to an approved set of plan. Changes include remove scope of work lighing and power in corridor area. Changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19685	14041-20000-28026	1801 W OLYMPIC BLVD 2nd Floor	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.05046	-118.27663	TI to existing commercial office space.  Existing lighting in open office area, plan check for energy in newly divided/enclosed spaces.  All loads on new panel schedule indicated as receptacle and appliance loads less than 25 kVA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19686	15041-10000-07897	611 W CESAR E CHAVEZ AVE	90012	1	133-5A213 181	5407016011	C2-2D	Central	Central City North	Historic Cultural		2071.01	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.06023	-118.24286	EMPTY LOT CONVERTED  TO OPEN PARKING LOT WITH POLE-SUPPORTED LUMINAIRESPLAN CHK IS FOR TITLE 24 OUTDOOT LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19687	17041-10000-22051	2110 W SUNSET BLVD Suite O	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.07735	-118.26408	PC FOR A DANCE STUDIO TI. TITLE-24 ENERGY ONLY.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1310 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19688	13041-10000-15382	5601 N DE SOTO AVE 2ND FLR,-BLDG. 2	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	13041-10000-15382 pc for energy only. B occupancy per applicant.CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE.  RENOVATION OF THE EXISTING PHARMACY FOR PTHTHALMOLOGY EXPANSION.  THE EXPANSION CONSISTS OF 6 EXAM ROOMS AND TWO OFFICES.  THIS SCOPE OF WORK ALSO INCLUDES THE....DECOMMISIONING OF THE EXISTING DUMBWAITER FROM 2ND FLOOR TO THE 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19689	13041-20000-32112	5021 N BELLAIRE AVE	91607	2	171B161   965	2357010009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.1619	-118.40955	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC. 34 MODULES AND 2 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19690	16041-10000-19803	1150 N CAHUENGA BLVD	90038	13	144B185   544	5533008003	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			06/06/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.09215	-118.3287	FULL PLAN CHECK. NEW 3 STORY, 29 UNIT APARTMENT BUILDING OVER ONE LEVEL BELOW GRADE PARKING.  NEW 1000A 120V/208Y 3PH-4W SERVICE.  9 TYP. UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19691	18041-10000-32193	953 N SYCAMORE AVE 8TH FLR	90038	4	144B181   718	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	ADDRESS	34.08865	-118.34299	FIRST TIME TENANT ON ENTIRE 8TH FLOOR. PLAN CHECK FOR POWER AND ENERGY.BLDG PERMIT: 18016-20000-27002	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19692	13041-10001-24414	9665 N JUMILLA AVE	91311	12	201B117   488	2761030057	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.2456	-118.56338	][][][EXPEDITED PER APPLICANT REQUEST][][][PV1 INSTALLING ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 13.25 KWDC ON CENTRAL-INVERTER NON-STANDARD PLAN, TRANSFORMERLESS.(53) MODULES: TRINA SOLAR #TSM-250PC05/PA05.18(2) INVERTER: POWER-ONE #AURORA PVI-5000-OUTD-US, POWER-ONE #AURORA PVI-6000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19693	18041-10000-35136	800 S FIGUEROA ST STE#1060	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.04771	-118.26116	TENANT IMPROVEMENT TO EXISTING OFFICE SPACE (1,030 SF) IN SUITE #1060. T-24 ENERGY ONLY.BUILDING PERMIT: 18016-10000-28604	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19694	14041-10001-15148	1424 S MAIN ST SUITE 8	90015	14	124-5A207 282	5133012008	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.03457	-118.26152	(((CHANGE OF ADDRESS. DEPARTMENT ERROR ZERO FEES)))T24, REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 3022  SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19695	15041-10000-31500	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.05494	-118.23752	TI for a cafe space, T-24 only, total area: 1281 sq. ft. Scope is inside the union station.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19696	18041-10000-38479	10250 W SANTA MONICA BLVD FC12	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR T.I. to existing food court restaurant. SCOPE INCLUDES NEW CIRCUITS LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 1080 SQ.FT. B#18016-10000-31302	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19697	14041-20000-00437	970 N MONUMENT ST	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	ADDRESS	34.04646	-118.52393	T24 FOR CHANGE OF USE FROM RETAIL TO BEAUTY SALON.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19698	15041-20000-35946	10585 W BUTTERFIELD ROAD	90064	5	126B161   610	4318014023	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.03794	-118.41665	Plan check for a PV1 roof-mounted PV system. System size is 2 kWac and consists of (8) modules and (8) micro-inverters. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19699	19041-10000-00336	10466 S VERMONT AVE	90044	8	090A199   176	6061003033	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.01	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Issued	01/04/2019 12:00:00 AM	ADDRESS	33.94098	-118.2914	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19700	19041-10000-19624	17612 W TRAMONTO DR	90272	11	126B117   376	4416021012	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	07/06/2019 12:00:00 AM	ADDRESS	34.04174	-118.55931	$0.00 fee per AB1414. [E-PLAN], PV1. NEW ROOFTOP SOLAR SYSTEM CONSISTING OF 48 MODULES (SUNPARK 300), 2 INVERTERS (SE7600H-US AND SE3800H-US) AND 48 OPTIMIZERS (SE P320). SCOPE INCLUDES NEW 100A LOAD CENTER*EXPRESS PERMIT IS REQUIRED FOR PANEL UPGRADE (200A)*.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19701	17041-10000-38944	1508 N LACHMAN LANE	90272	11	135B121    50	4420035004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.06302	-118.54979	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PV1, SOLAR ROOF MOUNTED SYSTEM USING TWO CENTRAL INVERTERS WITH (43) MODULES, (1) 5.2 INVERTER, (1) 6.6 INVERTER,  AND 125A LOAD CENTER. TOTAL PV SYSTEM SIZE IS 11.8KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19702	12041-10000-21625	222 S ALTA VISTA BLVD	90036	5	135B181    29	5512025006	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.07028	-118.34728	3.64 KW roof mounted pv for a single family. (system has power optimizer)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19703	11041-20000-26566	22100 W STAGG ST	91304	3	189B101   772	2012021015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.21072	-118.6084	New 1.38 KW roof mounted PV system for single family residence.  Applicant is using M215 inverters.  A variance has been filed to use the microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19704	19041-10000-35393	10 S CHESTER PL BLDG 8.5	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Info Complete	09/06/2019 12:00:00 AM	ADDRESS	34.03079	-118.27732	T-24 PLAN CHECK FOR A TI TO A STUDENT LOUNGE AT MOUNT SAINT MARY'S UNI. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1780 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19705	13041-10000-28623	380 WORLD WAY T41	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	"PLAN CHECK  FOR SIGN LIGHTING for ""Relay"". Controls under 13041-10000-15314. FIRST TIME TENANT AT TOM BRADLEY INTERNATIONAL AIRPORT. *****************************************************************13041-90000-14278. DESCRIPTION: PROPOSED 1841 SQFT. Electrical TENANT IMPROVEMENT FOR RETAIL SPACE (RELAY) Space T41"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19706	18041-10000-12890	19535 W NORDHOFF ST Bldg B	91324	12	198B117   256	2761035015	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	08/31/2020 12:00:00 AM	PIN	34.23636569	-118.55942295	PLAN CHECK FOR FIRE ALARM SYSTEM  FOR NEW 6 STORY MIXED USE  APARTMENT (214 UNITS) AND  RETAIL /RESTURANT (CORE & SHELL ONLY) OVER PARKING CONSISTING OF 1 FIRE ALARM PANEL & 987 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19707	13041-10000-05870	1421 E 41ST PL	90011	9	114A211    36	5116011020	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.00805	-118.24871	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 1.7 KW. 8 PANELS AND MICROINVERTERS. [MICROINVERTER: ENPHASE M215-60-2LL-S2X] [SOLAR  MODULE: YINGLI YL245P-29B].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19708	17041-10000-44328	333 S CHADBOURNE AVE	90049	11	129B137   269	4406024012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.05124	-118.49043	Plan check for battery backup system for Single Family Dwelling. Total battery backup system size: 10kW with (2) PowerWall 2.0.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19709	13041-10000-07850	334 S MAIN ST #1101	90013	9	129A213   129	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	ADDRESS	34.04841	-118.24668	FIRST TIME TENANT OF RETAIL SPACE IN MIX BUILDING. PC FOR POWER AND ENERGY. TOTAL AREA 2551 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19710	19041-20000-49037	1127 W 187TH PL	90248	15	060B197   410	6109015024	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	33.86065	-118.2934	PV1 PLAN CHECK FOR PV SYSTEM, SYSTEM SIZE IS 13.44 KW DC/10.08 KW AC. SCOPE OF WORK CONSISTS OF (42) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19711	16041-10000-37585	14547 W ARMINTA ST #D	91402	6	189B149   650	2210022042	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.21351	-118.45054	TI TO CHICKEN SLAUGHTER HOUSE AND RETAIL. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19712	19041-10000-17621	947 S TIVERTON AVE	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	09/23/2021 12:00:00 AM	ADDRESS	34.06246	-118.44303	NEW FIRE ALARM SYATEM WITH 984 DEVICES IN A COMMERCIAL BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19713	17041-20001-18737	5665 N RHODES AVE	91607	2	174B165   492	2340017014	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			PC Approved	06/21/2017 12:00:00 AM	ADDRESS	34.17399	-118.40322	EXPEDITEPV1INSTALLATION OF 20 ADDITIONAL PV MODULES TO AN EXISTING PV SYSTEM, SIZED 16.4KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19714	15041-10000-10711	6130 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.09779	-118.32344	T24 FOR EXISTING RITE AID DRUG STORE. CHANGING LIGHT FIXTURES IN 12500 SQRFT RETAIL AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19715	19041-10000-39373	3800 S FIGUEROA ST	90037	9	117A201    20	5037031023	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	08/17/2020 12:00:00 AM		Permit Finaled	08/12/2022 12:00:00 AM	ADDRESS	34.01552	-118.28256	FULL PLAN CHECK FOR A NEW MIXED USE RETAIL/RESIDENTIAL BUILDING. 7 STORY ABOVE GRADE WITH ONE LEVEL OF SUBTERRANEAN PARKING. 79-DWELLING UNITS. SCOPE INCLUDES TWO NEW SERVICES 1600A AND 2500A 208/120V 3PH 4W WITH A 200KW EMERGENCY GENERATOR ( NON HIGHRISE )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19716	18041-20000-29795	20802 W SPRUCE CIR (#73)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.29494	-118.58691	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19717	13041-10000-32867	13350 N LOS OLIVOS ST	91342	7	225B145   499	2501003038	(Q)RS-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.31448	-118.46885	PV1 8.25KWdc Installation of photovoltaic system using [(2) inverters: {SOLAREDGE SE3800A-US, SOLAREDGE SE5000A-US}]. [(33)modules: {Renesola {JC250M-24/BB}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}] -  PV WIRE USING LA TEST LAB APPROVED INDUSTRIAL WIRE PVX1019	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19718	17041-10000-29744	1263 E 40TH PL	90011	9	115-5A211 159	5114032020	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.01033	-118.25278	PC FOR PV SYSTEM 3.8KW AC USING CENTRAL INVERTER SYSTEM AND 14 MODULES. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19719	14041-10000-14415	4407 S METTLER ST	90011	9	112-5A207  80	5109014033	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.00365	-118.26669	pv1,standard  plan, install 1.775 kw dc roof-mounted solar array on a 1-story house interconnect with mai service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19720	11041-10000-13930	1850 N RISING GLEN ROAD	90069	5	150B169  1298	5561023026	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.10418	-118.38415	New 2-story single family residence.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19721	15041-20000-08279	14800 W VENTURA BLVD	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.15186	-118.45547	Plan check for the installation of a 350 kWac temporary emergency generator. Project site is an existing high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19722	15041-20000-38562	20437 W BASSETT ST	91306	3	183B109   717	2136013011	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.19585	-118.57856	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (19) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19723	16041-10001-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.23567	-118.5584	DELTA 3 REVISIONS TO PERMITTED SET OF PLANS. ATTACHED TO THE REVISED PLANS IS A LIST OF THE CHANGES WHICH ARE CLOUDED AND IDENTIFIED ON THE REVISED PLANS (((((((((((PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE  APARTMENT WITH 215UNITS.   AND RESTAURANT/ RETAIL CORE & SHELL.  FOUR FLOORS OF RESIDENTIAL OVER TWO FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL. THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMP, 4000 AMP, AND 1600 AMP.  TOTAL AREA = 408,828 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19724	12041-10000-02512	427 S BOYLE AVE	90033	14	127-5A221 224	5174002016	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Apartment			02/02/2012 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Expired	04/29/2014 12:00:00 AM	ADDRESS	34.04213	-118.21983	Plan check for 127KW roof mounted and grounded mounted photovoltaic system for an existing apartment buildind. New 400A service, switchboard, and electric vehicle charger. Site located in Methane Buffer Zone. Existing equipment shall be suitable for new fault current.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
19725	18041-10000-45904	17777 W VENTURA BLVD	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.16303	-118.51993	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19726	15041-10000-11330	515 S FLOWER ST 35TH FL	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.05134	-118.25661	ALTERATIONS IN OFFICE SPACE AND CORRIDORPLAN CHK IS FOR TITLE 24 AND 1 EA  EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19727	13041-10000-03199	380 W WORLD WAY T59	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	TI OF SPACE 656 OF NEW TOM BRADLEY TERMINAL AT LAX. PC FOR POWER AND ENERGY. FIRST TIME TENANT. TOTAL AREA OF 680 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19728	16041-10000-23755	2727 S FLOWER ST	90007	9	121-5A203 152	5123018023	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.02626	-118.2758	FULL PC FOR POWER AND ENERGY TO AN EXISTING USC BUILDING (OFFICE/MACHINE SHOP). SCOPE INCLUDES A NEW 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, AND NEW PANELS. TOTAL AFFECTED AREA IS 6839 SQ. FT. B#16016-10000-14231	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19729	16041-10000-31530	11455 W BURBANK BLVD	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	Fire alarm installation to an existing church of scientology. Adding 1 main Fire alarm panel, 3 communication panels, 6 boosters, and 393 fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19730	14041-10000-17280	1307 N SIERRA ALTA WAY	90069	4	144B165   115	4392016025	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.09393	-118.39427	plan check for power and energy. NEW SINGLE FAMILY DWELLING WITH HABITABLE BASEMENT (13,740 SQ FT). BLDG#13010-10-01232.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19731	11041-20000-23330	21700 W OXNARD ST #600	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	01/05/2012 12:00:00 AM	ADDRESS	34.17901	-118.60179	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR T.I. OFFICE BLDG ON THE 6TH FLOOR (SUITE 600). PERMIT FOR LIGHTING AND ELECTRICAL WORK ON EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19732	15041-20000-40200	555 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.13776	-118.3584	TI to existing commercial building (hotel). Remodeling kitchen and restaurant. Plan check for power and energy. Adding new lighting. Total sqft. 4,021.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19733	18041-20000-19285	519 N NORMANDIE AVE	90004	13	141B193  1133	5520012010	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	01/25/2021 12:00:00 AM	ADDRESS	34.08051	-118.30072	Plan check for Power and Energy for 14 units appartment building. Total common lighting area: 9,569 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19734	16041-10000-31353	10535 N SAMOA AVE	91042	7	207B197  1293	2566007029	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.26056	-118.28698	Plan check for PV roof mounted system. System size: 8.25kW with 33 modules(Suniva OPT280-60) and 33 microinverters(Enphase M250)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19735	10041-20001-06508	12155 W RIVERSIDE DR	91607	2	168B165   493	2356008009	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM			PC Approved	04/30/2010 12:00:00 AM	ADDRESS	34.15778	-118.39842	Plan check T-24 energy only for new lighting. Wiring existing to remain. Permit under #10041-90000-06508	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19736	18041-10000-45697	131 S LA BREA AVE UNIT 2	90036	5	138B181  1006	5513019010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.07261	-118.34429	PLAN CHECK FOR T24 FOR COMMERCIAL RETAIL SPACE. TOTAL SQ FT = 755PART OF PERMIT PAID UNDER 18041-30000-17950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19737	15041-20000-38199	17537 W TRIBUNE ST	91344	12	207B129    57	2712017006	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.26743	-118.51659	PV1, roof mounted solar panel, 6.89kW DC system (26)modules #KU2656ZPA, (1)inverter:PVI-6000-OUTD-US-Z-A(1) combiner boxProduction meter is installedStandard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19738	19041-20000-17182	725 S FIGUEROA ST 9th Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only. Project site is a portion of the 9th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,317 sq. ft.Note: Building application has been generated under 19016-10000-12021	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19739	13041-10000-16072	735 S FIGUEROA ST # 115	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	First time tenant -The pizza studio	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19740	17041-20001-09936	4115 S REDWOOD AVE	90066	11	108B153   995	4230006017	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM			PC Approved	05/08/2017 12:00:00 AM	ADDRESS	33.99062	-118.44021	Plan check for energy only. New restrooms and kitchen in commercial office space. New lighting in restrooms. 129sqft. Permit pulled under parent application #17041-90000-09936.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19741	15041-10001-30846	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.06725	-118.41704	03/10/16Changes to an approved set of plans. All changes are made under delta 4. Changes include adding 14 duct detectors and 26 Horn strobes. PC for voltage drop and battery calculations. (((install new fire alarm system for los angeles country club. 339 fire alarm device and one fire alarm panel and one control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19742	11041-10000-11766	670 W 9TH ST	90731	15	015B197   801	7454005019	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	07/18/2011 12:00:00 AM		Permit Finaled	05/29/2012 12:00:00 AM	ADDRESS	33.73616	-118.29158	INSTALL A NEW FIRE ALARM SYSTEM IN A NEW BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19743	15041-20000-14633	21550 W OXNARD ST Suite #495	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 plan check for high rise building Suite #495. Total area: 1,362 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19744	17041-20001-20159	6417 N FIGUEROA ST	90042	14	154-5A231 104	5493004008	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Apartment			02/06/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.11841	-118.18387	02-06-2019 Changes to an approved set of plan, changes include remove 1000A disconnect, all changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19745	16041-20000-40350	302 N LAVETA TER	90026	1	135A209    32	5160003008	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.06578	-118.26009	Plan check for energy only. TI - change of use from adult day care to office building. New lighting (incl. emergency) and receptacles. 7,725sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19746	13041-20000-02770	310 N FAIRFAX AVE	90036	5	138B177   379	5527037030	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	02/11/2013 12:00:00 AM	ADDRESS	34.07655	-118.36127	Change to lighting to an existing bank.  Load is less than 400 amps.  Plan Check Only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19747	17041-10000-12385	360 N STONE CANYON ROAD	90077	5	141B153   173	4362013015	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.08078	-118.44249	ELECTRICAL DESIGN FOR NEW SFD. PERMIT ISSUED UNDER BUILDING COMBO, THIS IS PLAN CHECK ONLY. B#08010-10000-00426	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19748	18041-10000-08001	767 S ALAMEDA ST 122	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	"PC FOR  RESTAURANT Tenant Improvement FOR TI-24 ENERGY ONLY. SCOPE INCLUDES NEW EQUIPMENT, TRANSFORMER, PANELS, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1108SQ.FT. Inspector to verify that ""F"" light fixture has UL listed sticker.  B#18016-10000-00237"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19749	11041-10000-20082	514 S SHATTO PL 2ND FL	90020	4	135B197   850	5077004025	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.06457	-118.28971	ALTERATIONS IN OFFICE SPACESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19750	18041-20000-32613	22026 W MAYALL ST	91311	12	204B101   483	2745004048	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	01/18/2022 12:00:00 AM	ADDRESS	34.25339	-118.60719	Plan check for PV roof mounted system, system size: 7.7kW with 30 modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19751	19041-20000-48473	5343 N OAKDALE AVE	91364	3	171B113    83	2164004002	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.16749	-118.56598	PV1.  Install 15.075 kW DC roof mounted PV system.  (45) modules with (23) 720W microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19752	18041-20000-10052	14761 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.17768	-118.45503	PLAN CHECK FOR POWER ONLY. NEW 1600 AMP SERVICE AND DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19753	19041-20000-26915	16650 W SHERMAN WAY	91406	6	183B137    70	2225005014	[Q]CR-1, [Q]CR-1VL, [Q]P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.2008	-118.49594	Tenant improvement for commercial office space on 1st and 2nd floor.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19754	16041-10000-44762	11844 N GLENOAKS BLVD	91340	7	216B157    60	2524001900	M2-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.28512	-118.42349	FULL PC FOR POWER AND ENERGY. CHANGE OF USE/OCCUPANCY OF 1-STORY LIGHT MANUFACTURING BLDG TO YOUTH CENTER.  SCOPE INCLUDES THREE NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. A-OCCUPANT LOAD > 100.  TOTAL AFFECTED AREA IS 12419.4 SQ. FT.B#16016-10000-09518	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19755	16041-20000-40826	516 W 140TH ST	90248	15	075B201    28	6132006021	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	33.90451	-118.28357	remove existing hid fixtures and replace with led.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19756	19041-10000-47640	1545 W WILSHIRE BLVD SUITE 700	90017	1	132A205   545	5142027036	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.05543	-118.26977	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES FOR AN EXISTING SPACE. TOTAL AFFECTED AREA IS 3306 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19757	16041-20000-17286	11046 W MAGNOLIA BLVD	91601	2	171B173   609	2353006014	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.16478	-118.3721	Plan check for Title 24 only in exising space, change of use from auto body shop to New Bar Lounge. Total area: 1,278 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19758	13041-10000-35773	13038 W SAN VICENTE BLVD	90049	11	129B137   498	4264001004	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.04835	-118.49101	Plan check for power and energy. First time tenant. Retail store in the mall. Tailored method.Total area 5133 sq ft.STE # A. Name of store: THEORY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19759	11041-10000-10023	1800 S FIGUEROA ST	90015	9	124-5A205 147	5126009005	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.10	Electrical	Electrical	Public Safety Only			05/17/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	10/19/2011 12:00:00 AM	ADDRESS	34.03562	-118.27103	installation of a fire warning system in a 2-stories commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19760	11041-20000-20098	14117 W HUBBARD ST SUITE H	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.29849	-118.44081	CHANGE OF USE FROM PORTION ( 5817 S.F) OF (E) RETAIL/OFFICE BUILDING TO RESTAURANT  & INTERIOR T.I. WITH NEW (611 S.F.) OUTDOOR DINING ARAE. SEE COMMEND	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19761	15041-20000-35056	12123 W VIA SANTA MARTA	91342	7	228B165    83	2581006***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/21/2015 12:00:00 AM	ADDRESS	34.31741	-118.39856	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19762	12041-10000-23795	6047 N CARTWRIGHT AVE	91606	2	177B177   487	2414014003	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.18076	-118.36389	This is a one story sfd. 12.75 KW, Two inverter, XFMRless. 50 modules. one sub panel and service up grade to 200 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19763	15041-10000-43531	5825 S VILLAGE DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	33.97536	-118.41564	Full plan check for a new building under a single plan, located in the same job site of a Methane ZONE, consists of  (6) new stand alone buildings with (6) different addresses and application numbers; Each building is identical and has 4-story and 6 units supplied by a 600-Amp service;  All electrical work for the plan are identical to  reference electrical applicaton #15041-10000-27550 located at the same site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19764	15041-20000-25804	4961 N BLUEBELL AVE	91607	2	171B161  1099	2357023036	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.16092	-118.41064	Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consist of (1) inverter, (36) modules, and (2) combiner boxes. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19765	18041-10000-18254	3125 W VERNON AVE	90008	10	111B185    69	5023010008	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/05/2021 12:00:00 AM	ADDRESS	34.00379	-118.3277	t-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM EXISTING OFFICE INTO A COFFEE BAR. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTING.  TOTAL AFFECTED AREA IS 860 SQ. FT.  B#16016-10000-30404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19766	16041-20000-45787	20908 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.21969	-118.58915	New service for a 7-11 store. #20908.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19767	19041-10000-14450	1875 CENTURY PARK EAST 1900	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	PIN	34.06084104	-118.41471001	HIGHRISE BUILDING OFFICE TI. PLAN CHECK FOR ENERGY: TOTAL EFFECTED AREA 2322 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19768	13041-10001-24633	2706-2708 E CESAR E CHAVEZ AVE	90033	14	127-5A225  74	5180017002	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2042.00	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.04493	-118.20391	Revision to approved plan.Change from 2 meter section to 6 meter, 800 Amp.  Addition of lighting. Plan check for power and energy for the change. (((((((((((((((((Plan check power and energy for T.I. commercial building with music studio, banquet hall, offices and dwelling unit. New 800A service supplying building.)))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19769	16041-20001-08558	18133 W VENTURA BLVD 201	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	(2/28/2016)changes to an approved set of plans.  changes include orientation of light fixtures to reflect filed conditions.  This is plan check only. (((PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. 2ND FLOOR OF A 4-STORY MED BUILDING. Medical outpatient center. 13,973sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19770	13041-10000-19873	2850 W SUNSET BLVD	90026	13	141A205    35	5426020009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	ADDRESS	34.08253	-118.27314	PLAN CHECK FOR PREVIOOUSLY PULLED PERMIT # 13041 10000 17110. TENANT IMPROVEMENT. TITLE 24 PLAN CHECK ONLY. 919 SQFT. INSPECTOR SENT BACK FOR PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19771	13041-20000-19743	13330 W RIVERSIDE DR	91423	4	168B157   334	2359023003	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.15738	-118.42406	T24 FOR MULTI PURPOSE AREA WITH STAGE. TOTAL SQRFT4220.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19772	19041-20000-53407	2915 W EXPOSITION PL Unit #4	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM				NEW ROOF MOUNTED 2.56KW PV SYSTEM WITH 8 @ 320W PANELS AND A CENTRAL INVERTERS ON AN APARTMENT BUILDING FOR UNIT #4.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19773	14041-10000-24227	4640 W HOLLYWOOD BLVD	90027	13	147B197   457	5542014007	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.10006	-118.29052	Energy plan check for commercial TI with total area 820 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19774	14041-10000-19296	5128 N BLUEBELL AVE	91607	2	171B161   692	2357002010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.16372	-118.41036	Installation of roof mounted solar PV system.  Total size = 8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19775	15041-10000-22833	9301 N TAMPA AVE Space #180	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Tenant improvement for 671 sq ft. retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19776	09041-10005-24270	380 W WORLD WAY NORTH-CONCOURSE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	THIS APPLICATION ADDRESSES CHANGES TO THE ORIGINAL DRAWING :PKG I  CONSISTS OF REVISED PANEL SCHEDULES(CHANGES ARE CLOUDED);PKG II SHOWS REVISED  WEST CORE DRAWINGS-NEW RECEPTACLES , THE PANEL SCHEDULE HAVE THE CHANGES CLOUDED;PKG III HAS  A FEW MORE DRAWING OF CHANGES SUCH AS THE RELOCATION  AND INCREASE OF THE SIZE OF THE ELECTRICAL ROOM RC7-45.Revisions of electrical plans for the north concourse at TBIT -Revisions are noted in  bulletins (GB1 to GB5). On the plans, each change is clouded and noted to the reference GB.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19777	14041-20002-33912	6256 N TOPANGA CANYON BLVD C-2250	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	CHANGES TO APPROVED SET OF PLANS. ADDED SOME LOADS AND CIRCUITS. RELOCATED SOME OUTLETS. PC FOR ALL CHANGES CLOUDED DELTA 2 AND 3 REVISIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19778	17041-10000-39134	943 S NORMANDIE AVE 1-8	90006	10	132B197  1087	5078001002	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			10/30/2017 12:00:00 AM			Reviewed by Supervisor	12/04/2017 12:00:00 AM	ADDRESS	34.05432	-118.30012	PC FOR NEW THREE STORY APARTMENT BUILDING WITH  8 UNITS STUDIOSSCOPE INCLUDES NEW 600 A 120/240V WITH NEW PANELS AND CIRCUITS. TOTAL AFFECTED AREA 5550 sq.ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19779	10041-10000-06204	791 S CENTRAL AVE	90021	14	124-5A213 440	5146007022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM			PC Approved	04/13/2010 12:00:00 AM	ADDRESS	34.03411	-118.24331	INSTALLING A 100 AMPS SERVICE AND ONE PANEL IN AN EXISTING GAS STATION FOR APROPANE DISPENSING STATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19780	19041-20000-31501	6850 ESTEPA DR	91042	7	198B201   146	2572039003	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	04/07/2020 12:00:00 AM	PIN	34.2413616	-118.28113274	Plan check for PV roof mounted system, PV system size: 4.96KW DC, 3.8KW AC with 16 PV Modules and 1 inverter(3.8KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19781	17041-10000-15294	2221 E WASHINGTON BLVD Bldg B	90021	14	118-5A217  73	5167019041	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.01912	-118.23236	PC for energy only, Outdoor Title 24. Removing HID fixtures and replacing them with new LED fixtures. Total area: 25,100 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19782	18041-20000-38493	4241 N ELLENITA AVE	91356	3	165B117   384	2180005002	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.14636	-118.56132	PV1.  Install 7.04 kW roof mounted grid tied PV system and 13.5 kWh energy storage system.  (22) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19783	19041-20000-26734	600 WORLD WAY UNIT 636	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	T24 PLAN CHECK FOR EXISTING COMMERCIAL SPACE IN LAX AIRPORT. LIGHTS AND OUTLETS ONLY, T24 CALCULATIONS INCLUDES NEW AND EXISTING LIGHTING. TOTAL SQUARE FOOTAGE = 535 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19784	14041-20000-20207	9221 N ARLETA AVE	91331	6	198B157   732	2625010002	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.23746	-118.42148	PV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 102.6KW AC. USING 9 CENTRAL INVERTERS. WITH 468 DC MODULES. CONNECT TO 208 3 PHASE LOAD SIDE. derate main to 1000A, peake demand has been provided. PERMIT FEE IS $0 DUE TO STATE SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19785	13041-10000-22113	7182 W BEVERLY BLVD	90036	5	138B181   438	5513001040	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	08/15/2013 12:00:00 AM	ADDRESS	34.07598	-118.34597	TITLE 24 PLAN CHECK ONLY. PERMIT ALREADY PULLED FROM INTERNET. # 13041-90000-19217. 2300 SQFT. EMERGENCY LIGHTINGS. 1 STORY. AMERICAN WEST BANK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19786	13041-10000-10976	865 N SANBORN AVE 4-11	90029	13	144A201   301	5427004005	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Apartment			04/29/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.0879	-118.284	PHOTOVOLTAIC SYSTEM FOR MULTI FAMILY DWELLING. PV2 SYSTEM ROOF MOUNTED. TOTAL SYSTEM SIZE 22KW. USING 88 PANELS AND 2 CENTRAL INVERTERS. TRANSFORMED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19787	16041-10000-26294	732 S SPRING ST	90014	14	127-5A211 161	5144015029	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Expired	09/20/2018 12:00:00 AM	ADDRESS	34.04346	-118.25305	Temporary Power for a new apartment building, 24 stories high rise, 300 units. Temporarty power will be provided from on site generator, no utility connection at this point. Equipment includes: 800A switchboard feeding cranes and panelboards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19788	14041-10000-17424	5916 N FIGUEROA ST	90042	1	151-5A229 114	5492015008	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.1106	-118.19037	NEW SERVIICE AND HOUSE PANEL FOR VACATED TENANT SPACES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19789	12041-20000-11509	16450 W VENTURA BLVD	91436	5	168B137   385	2284002044	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM			Reviewed by Supervisor	06/05/2012 12:00:00 AM	ADDRESS	34.15731	-118.49192	new servive to replace existing change voltage and equipments at gelson's encino	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19790	14041-20001-35093	14006 W RIVERSIDE DR Space #211	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM			PC Approved	04/08/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	"Changes to approved set.  Changing fixture type ""A"" model number to #DRDHNIC6S (wattage is the same) and fixture type ""DW"" lamp to Philips 13PAR/F25 3000 Dim (wattage is lower).  Removal of some bugeyes from plans.*****Previous Work Description*****Title 24 plan check only.  Total area = 1,222 sq. ft.T.I. to existing retail space.  Installation of lighting, recepticles, and two 100 A panels.  Tailored method used.  Backroom plan check at request of applicant."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19791	17041-10000-34053	5950 W FOREST LAWN DR	90068	4	165B189    11	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.1522	-118.31832	Install a new 4800:480VAC, 500KVA Transformer, Panels & equipment. All Load is designed for future only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19792	15041-20000-30081	412 E WHEELING WAY	90042	14	150A231   312	5301009032	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.10345	-118.18734	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (15 modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19793	19041-20000-47866	4615 N WINNETKA CIR	91364	3	168B113   382	2175027031	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.15541	-118.57071	PV1. INSTALL 13.2 KW DC PV SYSTEM WITH (40) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19794	12041-20000-18799	147 N LARCHMONT BLVD	90004	4	138B189   757	5515019020	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM			PC Approved	08/10/2012 12:00:00 AM	ADDRESS	34.07437	-118.32384	energy plan check gym. place	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19795	18041-10000-33057	1712 W TEMPLE ST	90026	13	136-5A207 130	5159004022	C2-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Issued	08/29/2018 12:00:00 AM	ADDRESS	34.06871	-118.26386	Plan check for T24 only, two tenants core and shell to get the space ready for lease and (2) new unisex restroom. TI will  be under separate permit.  (B# 18016-10000-05952)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19796	15041-10000-42218	531 S CERES AVE	90013	14	126A215    60	5147016025	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/24/2016 12:00:00 AM		Issued	02/24/2016 12:00:00 AM	ADDRESS	34.0408	-118.24069	PC for title 24, energy only to an existing werehouse. Adding new lighting and receptacles. New panel less than 400A total connected load. Sq ft = 1908	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19797	17041-20000-01092	15760 W VENTURA BLVD Suite 1700	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check for energy only. TI to existing commercial office in high rise building. New lighting (incl. emergency) and receptacles. 1,756sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19798	12041-10000-17353	17433 W TRAMONTO DR	90272	11	126B117   195	4416004034	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.04246	-118.55696	Plan check for Acessory building. Note that plan check fees were obtained at the submittal of plans for the main building (12041-10000-10793). Permit for the acessory building will be on this application .permit fee is in inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19799	14041-20000-03677	5726 N FULCHER AVE	91601	2	174B173   526	2337028007	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.17473	-118.37291	PV1, roof-mounted solar installation, to interconnect with (E) 100A main service. system sized @ 3 kW DC, with (12) modules & optimizers (OP250-LV) , (1) SE3000 solar edge inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19800	16041-10000-42534	642 S MAIN ST	90014	14	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.04426	-118.25074	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES ADDING NEW LIGHTING FOR AN EXISTING EXHIBIT AREA. 1722 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19801	15041-10000-38821	7270 W MANCHESTER AVE # 10	90045	11	096B157   625	4119026044	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	33.95959	-118.42143	FIRST TENANT-RESTAURANT- IN RETAIL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19802	12041-10000-10519	10850 W WILSHIRE BLVD	90024	5	132B153   338	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.05923	-118.44139	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE/BANK TI SUITE #100. PERMIT FOR NEW BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19803	18041-20002-00586	2044 S LINNINGTON AVE	90025	5	129B157   291	4317012048	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.05199	-118.42256	CHANGES TO APPROVED SET OF PLAN - CHANGES ARE INCLUDED AS DELTA 1 CHANGES ON LAYOUT. ORIGINAL PERMIT DESCRIPTION PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.6 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19804	12041-20000-07131	800 W WILSHIRE BLVD LP-1	90017	9	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	05/31/2012 12:00:00 AM	ADDRESS	34.0493	-118.25841	T-24 plan check for energy and emergency lighting. 1410 sqft lobby (indoor).TENANT IMPROVEMENT ON EXISTING VALET STATION AND LOBBY AREA AT PARKING LEVEL (LP-1). PROVIDE NEW FINISHES, MILLWORK, FINISHES AT VALET STATION AND REPLACE DOOR AT ELEVATOR LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19805	14041-10000-25912	12045 W WATERFRONT DR	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	33.98209	-118.40611	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT OFFICE FOR EXISTING 4 STORY BUILDING. 30 DAY DEMAND READING VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19806	17041-10000-19678	3611 S GRAND VIEW BLVD	90066	11	114B153   703	4248026040	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Issued	06/22/2017 12:00:00 AM	ADDRESS	34.00865	-118.43436	Installation of new roof mounted solar PV system on eixisting single family dwelling.  Microinverter system.  Total size = 10.25 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19807	10041-10000-22168	8601 S LINCOLN BLVD #160-#170	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	33.95939	-118.41943	Ti in an existing medical office building. plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19808	18041-20000-19655	12737 W DEWEY ST	90066	11	117B149    92	4247004014	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.01321	-118.44937	PV1.  Install 7.59 kW roof mounted grid tied PV system.  (22) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19809	19041-20000-40434	345 N ROCKINGHAM AVE	90049	11	132B137    43	4406002005	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2019 12:00:00 AM	05/22/2020 12:00:00 AM		Permit Finaled	06/21/2022 12:00:00 AM	ADDRESS	34.06151	-118.49107	INSTALL NEW 800 AMP 120/208V 3PH SERVICE. (1) MAIN 800AMP DPB WITH NEW PANELS AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19810	13041-10002-30030	6028 S EILEEN AVE	90043	8	105B181   741	4004023007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	33.98453	-118.34272	Expedited RSES plan check per applicant request.(((PV1.  Install 4 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US.  16 modules: Trina Solar TSM-250PA05.18)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19811	14041-20002-07472	7727 W FORSYTHE ST	91042	7	208-5A195 154	2557001030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM			PC Approved	05/08/2014 12:00:00 AM	ADDRESS	34.26607	-118.30118	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19812	16041-20000-08076	10330 N GERALD AVE	91344	12	204B137   205	2684017005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.2584	-118.49455	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19813	14041-20000-10303	11755 N SEMINOLE CIR	91326	12	213B117    49	2822020019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.28376	-118.55801	PV1. roof-mounted system with 8.01kw, (37) ET solar ET-P660250BB  modules,  (2) tranformerless inverter of SMA AMERICA SB5000TL and SB3800TL 240V.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19814	14041-20005-21443	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.19603	-118.45077	02/03/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta H. Changes have been made to the lighting. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Change to approved set of plans. Changes include Available Fault Current from 70kAIC to 41kAIC per LADWP, Service equipment  (Series ratting 65kAIC), panel board (Series Ratting 65kAIC). {{{{{{{{Plan check for power and energy (2008 Energy Code). New 49-unit apartment building, 3-stories. Fee calcs provided by applicant - verify. Fire alarm variance filed.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19815	15041-10001-29697	812 W 98TH ST	90044	8	093A199   269	6054005018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	33.94694	-118.2898	EXPEDITE PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19816	18041-20000-39686	22200 W TIARA ST	91367	3	177B101   258	2146021002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.17796	-118.61044	Plan check for a PV1 roof-mounted PV system. System size is 11.88 kWdc/9.5 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (36) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19817	17041-20000-16581	4023 N ROCK HAMPTON DR	91356	3	162B125    30	2184054010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.14425	-118.53674	PV1.  Install a 14.950 kW DC roof mounted grid tied PV system.  (46) modules with (1) 15.0 kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19818	13041-10000-03934	1340 S FIGUEROA ST	90015	9	126A205    58	5134010022	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			02/14/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.03951	-118.26852	PLAN CHECK FOR INSTALLATION OF FIRE ALARM SYSTEM ON 7 STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19819	10041-20000-12400	661 W REDONDO BEACH BLVD	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	33.89279	-118.28725	TI: EXISTING OFFICE TO BE CONVERTED COMMERCIAL SCHOOL ( >12TH GRADE ) WITH CLASSROOM, ASSEMBLY AREA, CLASSROOM WITH HEAVY EQUIOMENT. EXISTING WAREHOUSE USE TO REMAIN.This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19820	16041-30000-35121	2143 E BAY ST	90021	14	123A217   155	5166004017	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.03169	-118.22845	Plan check for power and Title 24.  Complete remodel of existing commercial building.  New 600 A service with 4 subpanels and associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19821	17041-20000-45813	1001 N SEWARD ST	90038	4	144B185   940	5532024007	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.08914	-118.33334	Plan check for power and energy. New 4-story+mezzanine commercial building over one level of basement parking. Core and shell. 4,000A 277/480V 3ph 4w service. T24 area: 137,229sqft. Project is located in methane zone. Building permit application #17010-10000-04278.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19822	15041-10000-27672	2829 W SLAUSON AVE	90043	8	108B189  1339	5006022030	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	33.98921	-118.32426	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTALL SQUARE FOOTAGE 12458	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19823	19041-20000-30941	1801 S CENTURY PARK EAST STE 1900	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM			PC Info Complete	08/08/2019 12:00:00 AM	ADDRESS	34.06201	-118.41537	Plan check for Title 24 Energy only Tenant Improvement to existing office. Total area: 2277 sq ft. B#19016-40000-22443	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19824	13041-20000-09241	6600 N TOPANGA CANYON BLVD Family rm	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for energy and emergency lighting. Family Room of Westfield Topanga Mall	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19825	17041-10000-18832	13368 W VALLEYHEART DR	91423	4	165B157   402	2360012003	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.14981	-118.42361	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FIXUTRES TO NEW LED TYPE FOR ENERGY SAVINGS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19826	18041-20000-08322	7230 N MEDICAL CENTER DR #101	91307	12	183B097    18	2021014042	QCR-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.20143	-118.62922	PLANCHECK FOR POWER. MEDICAL OFFICE. ADDITION OF 12 CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19827	10041-10000-03555	424 N LAKE ST BLDG  B	90026	13	138A205   242	5157016023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Public Safety Only			03/01/2010 12:00:00 AM	03/01/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.07133	-118.26879	NEW FIRE WARNING SYSTEM FOR CHILDREN'S INSTITUE, INC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19828	15041-10003-15988	5513 W RIDGE OAK DR	90068	4	153B193   144	5580027020	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.11482	-118.31	Supplemental PC: Performance meter removed. PC fee $0 per California State Bill 1222.Permit under 15041-10000-15988**PV1, INSTALL 7.19 KW DC ROOF-MOUNTED SOLAR ARRAY ON A RESIDENTIAL HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: SUNPOWER SPR 327ne-wht-d(1) INVERTER: ABB PVI-6000-OUTD-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19829	19041-10000-08992	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Issued	06/13/2019 12:00:00 AM	ADDRESS	34.18421	-118.60617	TI IN A GROCERY STORE. CHANGE OF USE FROM RETAIL TO MARKET. PLAN CHECK FOR POWER & ENERGY. TOTAL AREA: 34,000 SQR FT. OTHER RELATED PERMITS = SHELL: 18041-10K-43843, SERVICE UPGRADE: 19041-20K-04168BUILDING: 19016-10K-07097	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19830	17041-20002-35667	3055 W 5TH ST	90020	13	135A201    53	5077001016	R4-2	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.06535	-118.28598	$0 plan check fee per State Senate Bill SB 1222.Revisions to approved set.  Change of inverters to SolarEdge inverters and associated distribution. (((PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.44 KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19831	18041-10000-21707	20100 S WESTERN AVE	90501	15	057B193    32	7351021038	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Issued	06/12/2018 12:00:00 AM	ADDRESS	33.84877	-118.30902	PLAN CHECK FOR TITLE 24 ONLY TO REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19832	15041-10000-25184	15071 W ASTORIA ST	91342	7	219B145   609	2611028025	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.29291	-118.45965	PV1 ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY RESIDENCE. (1) POWER-ONE PVI3.8-OUTD-S-US-A INVERTER (13) SUNPOWER SPR327NE-WHT-D MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19833	18041-10000-44905	5701 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	33.93354	-118.38447	REPLACE FLUORESENT TROFFERS WITH NEW LED RETROFIT KITS & REMOVE INDOOR/OUTDOOR HID FIXTURES TO REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19834	16041-20000-36315	4295 N BAKMAN AVE	91602	2	165B173   646	2366012017	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.14756	-118.37799	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter, (19) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19835	18041-10001-30760	4911 N LOLETA AVE	90041	14	160-5A227  62	5689023021	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	34.13541	-118.19822	NEW ROOF MOUNTED 11.75 (AC) KW PV SYSTEM ON A SINGLE FAMILY HOME WITH 37 PV MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19836	16041-20000-30539	11762 N MONTE LEON WAY	91326	12	216B121   396	2872010022	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.28721	-118.54603	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.73 KW. MICROINVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19837	14041-10000-21699	12746 W JEFFERSON BLVD #2110	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM			Reviewed by Supervisor	08/25/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	First time tenant. Tenant improvement, new lighting. T24. New commercial space. Area = 5000 sq. ft. Installation of 2 100A panels with 30KVA transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19838	18041-10000-27074	822 S PLYMOUTH BLVD 1-4	90005	4	132B189   424	5090028007	[Q]R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			07/19/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.05909	-118.32404	PC FOR POWER AND ENERGY FOR A  PROPOSED 4 UNIT APARTMENT OVER GARAGE.NEW SERVICE 800A 120/240 1PH. SCOPE INCLUDES NEW SERVICE, PANELS AND CIRCUITSTOTAL AFFECTED AREA 4744 SQ.FT. B# 18010-10000-00053	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19839	14041-20001-13960	5121 N PENFIELD AVE	91364	3	171B113   310	2166008017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.16405	-118.56871	PV1.  Install 7.65 kW roof-mounted utility-interactive PV system.  Transformerless inverter w/ power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19840	18041-10000-23231	2984 N ALLESANDRO ST Unit #200	90039	13	150B213   731	5442024047	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			Corrections Issued	06/21/2018 12:00:00 AM	ADDRESS	34.10578	-118.24435	PC FOR ENERGY ONLY. CONVERT PORTION OF THE (E) MANUFACTURING BUILDING TO (N) OFFICES. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1811 SQ. FT. B#18016-20000-10515	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19841	11041-20000-14806	7230 N MEDICAL CENTER DR Ste #500	91307	3	183B097    18	2021014042	QCR-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	08/15/2011 12:00:00 AM	ADDRESS	34.20143	-118.62922	Instal new circuits and equipment for new medical gas room w/ 1-hr rating. (Div 5 permit was pulled unde# 60121157)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19842	14041-10000-25216	2050 S LONG BEACH AVE EAST	90058	9	118-5A213 202	5167014018	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.01809	-118.24277	Installation of new fire alarm control unit.  Smoke detectors and manual station using existing water flow switch.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19843	15041-20000-37473	1985 E ZONAL AVE SUITE 200	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.06159	-118.20463	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR USC PSC LEADERSHIP CENTER. SUITE 200. 2507 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19844	11041-10000-25402	6801 W HOLLYWOOD BLVD #257	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			Corrections Issued	11/29/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	"TENANT IMPROVEMENTS TO EXISTING STARBUCKS AND EXPANSION OF 330 SQ. FT., NEW STOREFRONT, SKYLIGHT, NEW ROOF & EXTERIOR WALL; ADD IRRG. 9'-5"" X 36'-10"" EXTENSION TO (E) RESTAURANT IN MALL.PLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19845	19041-20001-21996	13422 W BASSETT ST	91405	2	183B157   782	2328014017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Issued	09/27/2019 12:00:00 AM	ADDRESS	34.19567	-118.42547	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. SCOPE OF WORK CONSISTS OF CHANGING FROM FULL TO PARTIAL BACK UP LOAD, ADDITION OF A NEW SUB PANEL, AND RELOCATION OF LOADS ON SINGLE LINE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19846	19041-20001-38060	5127 N DUMONT PL	91364	3	171B109   256	2166016004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.16287	-118.58109	Revisions to approved set of plans.  Removal of (2) modules from system design, reorientation of modules, and interconnection detail changes.  System size is now 14.805 kW DC / 11.4 kW AC.  (47) modules with 3.8 and 7.6 kW rated inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19847	11041-20000-24258	11027 N LIMERICK AVE	91311	12	210B109   113	2707033008	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.27088	-118.58279	New 5.25 KW roof mounted Solar system using micro inverters for a single family residence.  A variance to use the microinverters has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19848	19041-10000-30789	1927 S WESTERN AVE	90018	10	126B193  1038	5073030070	C2-2D-O-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.03912	-118.30924	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19849	15041-20000-30219	13714 1/2 SHERMAN WAY	91405	2	183B157   987	2216027023	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	PIN	34.20070651	-118.43211614	Title 24 plan check only.  Total area = 948 sq. ft.   T.I. to existing commercial space.  New lighting, recepticles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19850	19041-10000-14618	16449 W TUBA ST	91343	12	204B137   375	2678019008	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.25669	-118.49084	Plan check for a 5kw AC / 5.12KW DC PV1 roofmounted system with (1) inverter, (16) modules and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19851	16041-10000-43644	2000 W SLAUSON AVE	90047	8	105B189    21	6001001001	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	33.98893	-118.31386	PC FOR ENERGY. REMOVE HID FIXTURES AND RPLACE WITH NEW LED FIXTURES. TOTAL (OUTDOOR) AREA 127,950 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19852	19041-10000-06418	1505 S SANTA FE AVE	90021	14	121-5A217 311	5167001042	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	03/07/2019 12:00:00 AM	ADDRESS	34.02645	-118.23008	TI FOR (E) WAREHOUSE/OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19853	16041-20000-03755	1933 W 60TH ST	90047	8	105B193   328	6001013011	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	33.98529	-118.31272	"""$0 permit fees due to senate bill 1222""Plan check for PV2 roof mounted system  Feed In Tariff (FIT)on commercial building. System size: 360kWac with 1562 modulesKOSOL ENERGIE KE24250 and 10 inverter SOLECTRIA PVI 36TL"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19854	11041-20000-00924	8420 N LANKERSHIM BLVD	91352	6	192B169   383	2632022002	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM			Not Ready to Issue	03/31/2011 12:00:00 AM	ADDRESS	34.22367	-118.38757	Install general lighting/emergency lighting.  Plan check for energy only.NOTE: Permit issued under 11041-20000-00921	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19855	19041-10000-25446	2000 S AVENUE OF THE STARS 30	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Issued	09/18/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	Energy plan check for a restaurant T.I  located on the ground floor of a commerical building. Scope includes new light and equipment with a total lighting area of 4040-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19856	16041-20000-21184	10359 W DIAMOND ST LOT 2	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19857	11041-10000-20909	2810 S FIGUEROA ST	90007	9	121-5A203 156	5123019025	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			09/30/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Finaled	03/08/2012 12:00:00 AM	ADDRESS	34.02626	-118.27698	Remodel exist. Mc D. restaurant, P/check for compliance with lighting reqmts. of T-24 including emergency egress and exit lights.(EXTERIOR FACADE REMODEL TO (E) MCDONALDS RESTAURANT, WORK ALSO INCLUDES  ACCESSIBILITY UPGRADES TO RESTROOM,  DRIVE-THRU AND SITE CONFIGURATION.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19858	15041-10000-13468	1149 S BROADWAY 4th FLOOR	90015	14	126A209   600	5139019900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.03859	-118.26015	Ti- 24 for (E) building, total sq. ft. 435.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19859	14041-10001-07618	414 N FAIRFAX AVE	90036	5	141B177  1435	5527030018	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.07869	-118.36128	"[[[[9/16/14 CHANGES TO APPROVED SET. DELTA 3 AND DELTA 4 CHANGES ONLY. ADDITION OF OUTDOOR FRONT AREA SALES LIGHTING, ONE EXIT SIGN AND FEW RECEPTACLES.]]]]]FULL PLAN CHECK POWER AND ENERGY. Core and Shell as well as TI for tenant at 414 [tenant spaces #410 and 412 shall have circuit breakers in panels C and B shall be installed in separate permits]. NEW 600 A 120/240 V 3P,4W. TOTAL AREA 1310 (INSIDE) SQ FT. BLDG# 13014-10-05319: CHANGE OF USE. Expedite fee on submittal 2. 3/25/2014 - mt Changes on plan: all panels rated for 42kaic through series rating, extra panel B removed, scope of work added to sheet E-1.  �This building is designed as a Core and Shell Building only; separate building, electrical and mechanical permits are required for all future residential unit build-outs or commercial tenant space build-outs.�{{{ Description  of  the  building   first   floor   16'8""   x  65'10"" FROM RETAIL TO TAKE-OUT RESTAURANT.     ADD NEW 300 SQ FT. MEZZANINE  ( irregular 14.25'  x  25.25') and (N) STAIRCASE.}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19860	11041-10000-08970	8713 S CROCKER ST	90003	9	096A205    45	6041017005	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Expired	09/10/2013 12:00:00 AM	PIN	33.95867432	-118.26845828	Install new overhead service at existing storage  building.  The new overhead service will be combined with existing overhead service.  A new electrical room was created to hold the new and existing service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19861	10041-10000-17592	1241 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.05185	-118.2259	Solar voltaic system installed on the roof of the building.  Consists of 15 modules,  15 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19862	11041-20000-17210	1205 E 6TH ST	90013	14	126A215   332	5164009012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			08/15/2011 12:00:00 AM			PC Approved	08/15/2011 12:00:00 AM	PIN	34.03841309	-118.23802517	PLAN CHECK T24 ENERGY FOR EXISTING LOW-RISE APARTMENT/HOTEL BASEMENT AND LOUNGE AREA. ALL WIRING FOR LIGHTING ARE EXISTING TO REMAIN. EXISTING PERMIT #11041-10001-10627	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19863	17041-10000-04423	11967 W SUNSET BLVD	90049	11	135B141   909	4402010016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.06222	-118.47401	PC for Title 24. Outdoor, including excempt lighting. Removing HID fixtures and replacing them with new LED ones. Area: 38,800.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19864	18041-20001-43428	11541 W CANTON DR	91604	2	159B169   309	2377017003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.13308	-118.38501	expeditepv1install roof mounted pv system sized 10.7KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19865	19041-10000-14813	5441 W 104TH ST	90045	11	090B173   264	4129033004	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	33.94208	-118.37581	Full plan check per applicant request for a change of use from warehouse to photo studio and interior alteration. Scope include new equipment and lighting with a total area of 14,085 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19866	13041-20003-11563	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM			PC Approved	04/02/2015 12:00:00 AM	ADDRESS	34.09818	-118.32309	CHANGE IN FIRE PUMP FEEDER TO 2 HOUR RATING CABLE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19867	11041-10000-14132	433 S SPRING ST	90013	14	129A211    54	5149024016	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM			Corrections Issued	08/10/2011 12:00:00 AM	ADDRESS	34.04822	-118.24907	New 100 HP fire pump for high rise building.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19868	14041-20000-34676	15233-15237 W STAGG ST	91405	6	189B145   533	2209032026	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.21218	-118.46511	Plan check for energy only. TI to existing building, create office spaces. New lighting (incl. emergency) and receptacles. 4,739sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19869	17041-10000-05473	1115 N LEMOYNE ST	90026	13	139-5A207 179	5404016019	C2-1L-CDO, R4-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.07626	-118.26038	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR) 8300 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19870	18041-20000-36866	1187 N PIEDRA MORADA DR pv1	90272	11	135B117   111	4431032006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Closed	10/20/2021 12:00:00 AM	ADDRESS	34.06752	-118.55155	pv1install roof mounted pv system sized 11.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19871	16041-10001-44582	1660 W BEVERLY BLVD	90026	13	135A207   240	5153012003	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM			PC Info Complete	08/17/2017 12:00:00 AM	ADDRESS	34.06404	-118.26497	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. CHANGE TO FLOOR PLAN LAYOUT. UPDATED CIRCUITING AND PANEL SCHEDULES. UPDATED LIGHTING AND T24 DOCUMENTS. NO CHANGE TO SINGLE LINE OTHER THAN CORRECTED SIZE OF SE CABLES. ADDING ADDITIONAL 9KVA HVAC EQUIPMENT ON PANEL M2.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19872	11041-10000-12357	9058 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	34.23458	-118.55336	TI TO AN EXISTING RETAIL STORE.    PLAN CHECK FOR ENERGY ONLY, OTC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19873	14041-10000-27859	11220 S HINDRY AVE	90045	11	087B173   101	4129038019	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Closed	04/24/2017 12:00:00 AM	ADDRESS	33.93221	-118.37223	Plan check for lighting and power for existing commercial space. New 800 amp service with (5) new panels and (1) 150 kVAtransformer. Area = 35,070 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19874	15041-20000-14172	6320 N TOPANGA CANYON BLVD G-1665	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Issued	07/27/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title-24.  Total area = 1,389 sq. ft.  T.I. to retail first time tenant.  Two new panels and one new transformer.  Lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19875	16041-10000-12184	450 S WESTERN AVE UNIT 208	90004	13	141B193  1007	5521014010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	PIN	34.08110598	-118.30876361	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL.  FIRST TIME TENANT.  FULL PC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19876	16041-10000-02306	12690 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	33.97692	-118.41538	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) MODULES(1) 3000 INVERTERSOLAR CLEARANCE FOR THIS APPLICATION WILL HOLD FOR UNITS 2 AND 3 UNDER THIS SAME ADDRESS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19877	14041-10000-17173	13131 W NIMROD PL	90049	11	129B137   291	4407011013	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.05105	-118.49622	PV1, INSTALL 7.905 KW DC ROOF-MOUNTED SOLAR ARRAY ON TWO-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(31) MODULES: TRINA SOLAR TSM-255PA05.18(2) TRANSFORMERLESS INVERTERS: AURORA PVI-3.6-OUTD-S-US-Z-A &PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19878	16041-10002-10054	2108-2110 W SUNSET BLVD	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM			PC Approved	05/08/2017 12:00:00 AM	PIN	34.07718395	-118.26405818	Changes to an approved set of plans. All changes are cloued. Changes include removing mezzanine lights and changing lighting fixture from LED to flourescent.  Updated Title 24 calculations and revised emergency photometrics.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19879	19041-10000-08224	1800 N PASADENA AVE	90031	1	138A219    38	5447021022	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.07311	-118.22313	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19880	16041-10000-36151	3959 S SYCAMORE AVE	90008	10	117B177   404	5029003002	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.01511	-118.35824	PV1. NEW SOLAR SYSTME ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(8)MODULES-HYUNDAI HIS-M260RG(8)OPTIMIZERS-P300(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19881	17041-10000-42735	829 N BUNKER HILL AVE	90012	1	135A213   149	5407007036	R4-1	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Apartment			11/28/2017 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.06426	-118.24324	PC FOR POWER ONLY FOR AN APARTMENT BUILDING. SCOPE INCLUDES ADDING THREE 200A SUBPANELS, AND NEW CIRCUITS FOR THREE ADDITIONAL APARTMENT UNITS TO EXISTING 11-UNIT APARTMENT BUILDING.  SUBMIT PER APPLICANT REQUEST. B#17016-20000-25292	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19882	10041-10000-19788	888 W 6TH ST	90017	9	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	34.05062	-118.25846	LOBBY AREA EXPANDED TO INCLUDE A NEARBY VACANT TENANT SPACE; NEW LUMINAIRES ADDED AND CONNECTED TO LIGHTING CKTS AERVING THE LOBBY AREAPLAN CHK IS FOR TITLE 24; TIME CLOCK IS EXISTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19883	18041-20000-48449	20634 W YORKSBORO LANE	91364	3	168A111    58	2174005027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.15543	-118.58305	Plan check for PV roof mounted system, system size: 18.82 kW DC, 19.99kW AC with 53 PV Moduels and 53 microinverters connected to 400A existing service.Fees $24.21 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19884	10041-20000-13596	10880 W WILSHIRE BLVD 17th fl	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	energy paln check  17th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19885	14041-20000-19857	16115 W CELTIC ST	91344	12	210B141   874	2667006017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.26922	-118.4831	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.59KW INTERCONNECTED WITH MAIN SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19886	13041-20000-29101	333 S GRAND AVE 11th flr	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	T24 FOR HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON 11TH FLOOR IN BATHROOM AND CORRIDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19887	10041-10000-25237	600 W 7TH ST	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	05/06/2011 12:00:00 AM		Permit Finaled	02/17/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	BUILT-OUT FOR NEW DATA CENTER ( SUITE 570 ) AND ELECTRICAL ROOM ( # 440 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19888	17041-10000-12164	1650-1654 S SAWTELLE BLVD	90025	11	129B149   536	4261008014	(T)(Q)RAS4-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			04/13/2017 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	08/11/2021 12:00:00 AM	ADDRESS	34.04594	-118.44777	PC for power and energy for new 5 story 48 unit apartment with three levels of subterranean parking located in Methane zone. PC for new 1600 A 120/240V service, equipment and panelboards. Building #16010-30000-05136. Fire Alarm has beeen filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19889	11041-10000-06552	8938 N SEPULVEDA BLVD	91343	7	195B145   138	2654005016	M1-1	North Valley	Mission Hills - Panorama City - North Hills			1175.10	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			PC Approved	04/01/2011 12:00:00 AM	ADDRESS	34.23342	-118.46735	T.I.  SINGLE STORY WAREHOUSE.  NEW OFFICES.  PER INSPECTOR: TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19890	15041-20000-15963	13056 W AZTEC ST	91342	7	228B161   605	2511030022	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.32029	-118.41703	Installation of new roof mounted solar PV array.  Total system size = 4.76 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19891	15041-10000-12395	2740 N GRIFFITH PARK BLVD	90027	4	150A205    12	5433026037	P-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.10763	-118.27311	PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT. TOTAL AREA 846 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19892	19041-10000-23840	1174 S LA BREA AVE	90019	10	132B181  1219	5084021016	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.054	-118.3433	New Methane detection system with (2) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19893	12041-10000-20789	20201 W ACRE ST	91306	12	195B113   312	2781034005	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.23003	-118.57345	Plan check for 5.232KW roof mounted photovoltaic system (Aurora Transformerless Inverter). Single family dwelling. Permit to include service and main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19894	10041-10000-12043	4965 E HUNTINGTON DR NORTH	90032	14	144A233   284	5306014053	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.08771	-118.17537	Ti in an existing restaurant. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19895	12041-20000-15985	7920 W SUNSET BLVD Suite 400	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM			PC Approved	07/11/2012 12:00:00 AM	ADDRESS	34.09787	-118.36238	T24 and emergency lighting plan check for remodeled office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19896	12041-10001-19227	11661 W SAN VICENTE BLVD	90049	11	132B145   485	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	34.05407	-118.46431	PLAN CHECK FOR FIRE ALARM REPLACEMENT IN A HIGH RISE BUILDING. ADD NEW AND REPLACE NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19897	17041-30000-33888	10101 W CHEVIOT DR	90064	5	123B165   236	4316015018	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	07/28/2022 12:00:00 AM	ADDRESS	34.03571	-118.40413	Plan check for PV roof mounted system of SFD. System size: 11.4kW with 46 modules Solarworld SW295 MONO 295 modules and 1 inverter(11.4kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19898	12041-10000-24731	10720 W CHALON ROAD	90077	5	141B149   146	4362003035	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM			PC Info Complete	09/10/2013 12:00:00 AM	ADDRESS	34.08291	-118.44997	2-stories accessory living quarters  MAIN SFD IS ON 12041-10000-24729	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19899	15041-10005-24962	8533 N WOODLEY AVE	91343	12	192B137   107	2689025027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.22563	-118.48545	Changes to approved set of plans. Change of conductor size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19900	18041-10002-07709	8913 W 25TH ST	90034	10	126B169  1229	4302015022	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.03864	-118.3858	SUPPLIMENTAL FOR THE ENERGY STORAGE SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19901	18041-10000-09840	5200 N LANKERSHIM BLVD # 170	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC for T24 for new lighting for TI in office. Installing new lights and receptalces. Total area 1080sqft.B#18016-10000-04381B:Tenant Improvement at Suite # 170 of ( e ) office builsding : new non bearing partition walls ; partial ceiling panels ; new double door at entry ; finishes . ( 1000 sf ) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19902	19041-10000-09631	2426 W 8TH ST	90057	1	132A201   139	5141024023	C2-1	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.0564	-118.28173	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19903	15041-10000-02748	1416 S CHANNING ST	90021	14	120A215    22	5167017014	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.02469	-118.23798	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 10608 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19904	12041-20000-02454	15260 W VENTURA BLVD #1520	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.15356	-118.4658	T.I. for a high rise building.  Install general/emergency lighting on the 15th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19905	14041-20001-05191	12695 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	33.97727	-118.41529	((EXPEDITE FEES)))((EXPEDITE FEES)))Roof mounted PV system with 3KW AC USING TRANFORMERLESS INVERTER. THIS IS PART OF A SERIES SET OF SUBMITTALS. THIS PV SYSTEM TO INTERCONNECT TO COMMON SERVICE. THIS IS PROJECT 3 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19906	16041-10000-36703	651 WORLD WAY	90045	11	090B165   118	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	33.94326	-118.4019	TEMP SERVICE FOR TRAILERS. PROVIDING FEEDER FROM MAIN SERVICE AND GENERATOR AS WELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19907	18041-10002-02493	1353 W 60TH PL	90044	9	105B197   439	6003017023	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	33.98513	-118.2998	Supplemental for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19908	13041-10000-14118	4550 W PICO BLVD SUITE C321	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	07/02/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR AN EXISTING TENANT SPACE. SCOPE OF WORK < 400 A. PROJECT LOCATED IN METHANE ZONE. NO UNDERGROUND WORK IN SCOPE OF WORK. TENANT IMPROVEMENT PER BUILDING APPLICATION NUMBER 13016-10000-10762.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19909	19041-10000-51859	9227 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	04/24/2020 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.23663	-118.38075	PLAN CHECK FOR POWER ONLY, SCOPE INCLUDING AN  ADDITION OF A SUBMERSIBLE PUMP, AND A FUEL MANAGEMENT SYSTEM IN A DISEAL FUEL STATION FOR WASTE MANGEMENT TRUCKS.  PER BUILDING((19020-10000-02884))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19910	18041-20000-02811	16662 W PINERIDGE DR	91344	12	219B137   149	2609012020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.29372	-118.49581	Plan check for the addition of (2) Tesla PowerWalls to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19911	13041-20000-16196	4742 N SEPULVEDA BLVD	91403	4	168B145   532	2264004012	R3-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			06/20/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.15698	-118.46577	NEW 3-STORY, 19 UNIT APT. BLDG. OVER BASEMENT PRIVATE GARAGE. TOTAL SERVICE SIZE IS 1200A. ALREADY PAID FOR FIRE ALARM VARIANCE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19912	19041-20000-36987	1377 N SERRANO AVE 3RD FLR	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.0965	-118.30717	T.I. TO (E) OFFICE P.C FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19913	12041-10000-25363	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.14947	-118.43885	Fire Alarm system with 325 Devices and 1 panel for a Ralphs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19914	14041-10002-21615	1754 W SLAUSON AVE	90047	8	108B193  1385	6002001001	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	33.98899	-118.30847	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  CHANGES INCLUDE REVISIONS TO LIGHITNG FIXTURES AND ENERGY CALCS.PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM NAIL SALON TO RETAIL . 7-11	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19915	19041-10000-10255	13100 N TELFAIR AVE 2nd floor	91342	7	222B141    52	2604002048	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.30763	-118.47752	REPLACE INDOOR FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19916	14041-10000-13129	12702-12704 W MOORPARK ST	91604	2	165B161   326	2375007046	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Apartment			05/16/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.15012	-118.40957	plan check for power and energy. BLDG#14010-10-00915:PROPOSED 12 UNIT APARTMENT 4 STORY OVER BASEMENT GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19917	11041-10000-13723	900 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	08/10/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.04526	-118.26611	THE APPLICATION IS TO CONSOLIDATE ALL CHANGES ON PLAN SETS AND CREATE ONE SINGLE AS-BUILT SET OF PLANS.  PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19918	11041-20001-25373	9157 N DE SOTO AVE A bld 2	91311	12	198B109   148	2746009047	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM			PC Approved	12/19/2011 12:00:00 AM	ADDRESS	34.23726	-118.5888	Modification to an approved set of plans.  Modification include the general layout, the lighting layout, and the addition of a yogurt station with teh required cistcuits.  Plan check only. Contractor will pull the permit for the yogurt circuits separately.  <<<<quiznos tenant improvement new building>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19919	16041-20000-32815	11824 N MCLENNAN AVE	91344	12	216B133   630	2610002032	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.28476	-118.50071	Plan check for a PV1 roof-mounted PV system. System size is 9.8 kWac and consists of (34) modules, (2) inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19920	15041-20000-15937	1830-1840 1/2 N EL CERRITO PL	90068	4	150B181   513	5572032007	R3-1XL	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	Apartment			05/26/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.10478	-118.34501	Chage out existing meter section to new 600A meter section. Run new feeders to units #1838 and 1840 1/2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19921	16041-10001-12997	508 W BERNARD ST	90012	1	136-5A215 154	5414006029	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	34.06723	-118.23769	PC FOR ENERGY. CHANGES TO  APPROVED SET OF PLANS. CHANGES SHOWN AS DELTA 3. INCLUDES CHANGES OF LIGHT FIXTURES, LAYOUTS AND EMERGENCY LIGHTING.--------------------------------------------------------------------------------------------------------------------------------- Note: Phase 1 of project is under PCIS#15041-10000-42782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19922	18041-10000-48872	138 N BEAUDRY AVE	90012	1	133-5A211 258	5160030015	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.06001	-118.2534	T-24 PLAN CHECK FOR A TI OF A MIXED USED BUILDING. SCOPE INCLUDES REPLACING LIGHTING INDOOR/OUTDOOR COMMON AREAS. EMERGENCY AND EGRESS LIGHTING ARE EXISTING TO REMAIN. TOTAL AFFECTED AREA IS 4229.6 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19923	14041-20000-34027	7317 N RESEDA BLVD	91335	3	186B125   819	2118015009	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	34.20355	-118.53632	PV2 Install a roof-mounted solar array on a commercial building. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system., 22  240W pv modules across two strings (11+11).Note: Permit is under 14041-20000-32680	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19924	14041-20000-05285	3831 N WINFORD DR	91356	3	162B121    38	2177047021	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.14067	-118.55035	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 9.8KWAC. USING SOLAR OPTIMIZERS $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19925	13041-10002-35622	11975 W BLUFF CREEK DR BLDG#5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.98224	-118.40247	Changes to approved set.  Additional circuits, revised loads.  (((CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  35945 SF WITH NEW SURFACE PARKING LOT. TITLE 24 ENERGY FEE CHARGED UNDER BUILDING 3.  3 TOTAL BUILDINGS.  THIS IS BUILDING 5/5 IN THE SAME PARCELBLDG PERMIT: 13010-10000-04245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19926	17041-20001-01127	2106 N CEDARHURST DR	90027	4	150B201   229	5591007001	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.11024	-118.28482	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 175A. 3.8kW ungrounded system. (13) 290W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19927	19041-20000-07120	5015 N EAGLE ROCK BLVD	90041	14	162A221   218	5686021030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.13746	-118.21479	T24 PLAN CHECK FOR EXISTING COMMERCIAL SPACE, LOW RISE, LIGHTS ONLY, TOTAL SQUARE FOOTAGE = 1758 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19928	10041-20000-14666	11100 W SANTA MONICA BLVD 5th floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	10/15/2010 12:00:00 AM	ADDRESS	34.04726	-118.44465	core and shell for 5th floor for common area. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19929	19041-10000-52737	3128 S CURTS AVE	90034	10	123B169  1112	4312009032	RD1.5-1-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Expired	11/18/2023 12:00:00 AM	ADDRESS	34.03114	-118.3885	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 24 MODULES (Q,PEAK DUO BLK-G5/SC315), 24 OPTIMIZERS (P400), 1 CENTRAL INVERTER (SE7600H-US), 1 ENERGY STORAGE SYSTEM, 1 PANEL OF 125 AMPS, AND 1 PANEL OF 200 AMPS.  SYSTEM SIZE: 7.56 KW DC; 7.6 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19930	17041-10000-41784	1801 S CENTURY PARK EAST 2200	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.06201	-118.41537	PC FOR OFFICE TI IN HIGH RISE BUILDING (22N FLOOR) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 3050SQ.FT.B#17016-10000-28261	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19931	14041-10000-02537	9672 N LARAMIE AVE PV1	91311	12	201B113   666	2748027001	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.24591	-118.57345	5.8 KW DC ROOF MOUNT PV, (24) MODULES, (1) TRANSFORMERLESS INVERTER (POWERONE PVI-5000-OUTD-US).  MODULES: TALESUN SOLAR TP660P-B-240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19932	18041-10000-26114	725 S FIGUEROA ST STE 2250	90017	14	129A207   336	5144009093	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	TI IN AN EXISTING OFFICE AREA IN SUITE #2250. AREA: 4152 SQR FT.T-24 ENERGY ONLY.   BLDG PERMIT # 18016-10000-19506	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19933	19041-10000-10131	14747 W ORACLE PL	90272	11	132B129    36	4422033004	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.05569	-118.52046	PV1. NEW ROOFTOP SOLAR SYSTEM CONSINSTENT OF 27 MODULES (SOLARIA 350), 27 MICROINVERTERS (ENPHASE IQ7+) AND A 200A LOAD CENTER. SYSTEM SIZE IS 8.33kw DC / 7.8KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19934	19041-20000-36643	6240 N RANDI AVE	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	06/01/2022 12:00:00 AM	ADDRESS	34.18396	-118.61008	PV2.  Plan check for PV roof mounted system, System size: 25.230KW DC, 22.5KW AC with 58 PV Modules and 2 inverter(14.4KW and 9.0KW )Note: This is 12 buildings on 1 Plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19935	17041-10000-45709	7156 W VALMONT ST	91042	7	204B197  1094	2568007001	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.25219	-118.2878	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19936	12041-10000-12440	3566 W BEVERLY BLVD	90004	13	138A201    78	5501007005	M1-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.07391	-118.28653	NEW  2 STORY ( TYPE V-B)  BUILDING WITH VETERINARY CLINIC  ON THE IST FLOOR AND PART OF SECOND FLOOR . OTHER PART OF SECOND FLOOR IS FOR FUTURE TENANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19937	15041-20000-09155	14812 W SATICOY ST	91405	6	186B149   201	2218001010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.20832	-118.45585	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter, and (10) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19938	13041-20003-22680	1550 N WILCOX AVE	90028	13	148-5A187 338	5546013002	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.09947	-118.33087	CHANGES TO APPROVED SET OF PLANS. CHANGE IN CONTROLS AND AND MINOR CIRCUIT REVISIONS. PLAN CHECK FOR CLOUDED CHANGES ONLY. THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19939	12041-20000-19329	16501 W VENTURA BLVD	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM			PC Approved	08/16/2012 12:00:00 AM	ADDRESS	34.1578	-118.49275	Replace general/emergency lighting in the corridor of levels 2, 3, 4, 5,  and 6.  Plan check for energy only.Note: Permit issued under 12041-90000-19039	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19940	13041-20000-13598	17511 W DEVONSHIRE ST	91325	12	204B129   138	2733014045	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	ADDRESS	34.25778	-118.5161	Plan check for energy only. Outdoor parking lot. Young Israel of Northridge.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19941	10041-10000-08359	1305 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.05141	-118.22491	Pv system for appartment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19942	13041-20000-04836	6069 W SUNSET BLVD	90028	13	147A189    49	5545008002	C4-1-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.09819	-118.32119	New two story studio building with offices.  Full plan check.  Recalculate and charge the energy fee based on 51087 SF of exterior lighting which is approximately $661.00 at time of first plan check review. Green Building requirements have been approved by Green Building Department.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19943	18041-20000-19167	10877 W WILSHIRE BLVD 23 Floor	90024	5	132B153   297	4360003029	[Q]C4-3-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05934	-118.44254	Plan check for power and energy per applicant request. T.I. office space high-rise building on 23rd Floor. Total area: 12786 sq ft. B#18016-100000-15805	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19944	10041-20000-12737	15544 W SAN FERNANDO MISSION BLVD	91345	7	210B145   159	2664018030	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1092.00, 1093.00	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM	07/23/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	ADDRESS	34.2717	-118.47115	TI FOR 7-11. POWER AND LIGHTING BY UPGRADING TO 600AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19945	15041-10000-14013	7820 S KENYON AVE	90045	11	099B161   185	4112022008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	33.96946	-118.41236	PV1, Install 2.75 kW DC roof-mounted solar array, interconnect with service panel. new utility lockback AC disconnect. (11) panels 11 microinverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19946	11041-20000-12299	1828 S WESTERN AVE	90006	10	126B193   744	5074015045	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM			PC Info Complete	11/07/2011 12:00:00 AM	ADDRESS	34.04091	-118.30873	T.I. to existing building of the coin laundry.  Install new panels with new load exceeds 400 amps.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19947	19041-10000-30056	5138 S BROADWAY	90037	9	108B201    85	5110026033	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Apartment			08/02/2019 12:00:00 AM	06/07/2021 12:00:00 AM		Permit Finaled	12/02/2022 12:00:00 AM	ADDRESS	33.99574	-118.27811	Full plan check for power and energy. A 800A service supplies a 49 units,  modular multi-family building certified by the California Department of Housing and Community Development .Plan check review are for those components not certified by HCD.Note: Fee estimate only, customer brought in a precut check, plan checker to adjust final fees accordinglyB#: 19010-10000-03307	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19948	14041-20001-31865	11938 W RUNNYMEDE ST #A & B	91605	6	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.20563	-118.39354	Fee for expedite only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19949	16041-20003-11387	8301 N CANOGA AVE	91304	3	192B105   594	2779036013	C2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.22025	-118.59775	2/12/2018changes to an approved set of plans.  changes to match field conditions.  changes noted delta 2.  changes include additional circuits and removal of light fixtures.  (((Plan check for power and energy. Project site is a new gas retail/market building and gas station. DWP service is existing (gas station is replacing car wash). Total lighting area = 24,086 sq. ft.Note: Building permit has been created under 16010-20000-00069)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19950	18041-20000-11480	13895 W NURMI ST	91342	7	228B153   354	2503005045	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Issued	03/29/2018 12:00:00 AM	ADDRESS	34.32108	-118.43647	PV1.  Install 20.460 kW DC roof mounted grid tied PV system.  (62) modules with power optimizers and (2) 7.6 kW rated central inverters.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19951	18041-20000-06690	2229 W VENICE BLVD	90006	10	126B193   236	5074012019	[T][Q]C2-2-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.04371	-118.30705	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19952	16041-20000-19402	3239 N PASADENA AVE Unit C	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	PV2.  Install 2 kW DC roof mounted PV system.  (7) modules with (1) 3 kW transformerless inverter with power optimizers.  3 of 3 PV systems proposed for property submitted concurrently.Zoning clearance obtained under 16041-20000-19398	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19953	12041-10000-07448	720 E E ST 1st floor	90744	15	030B209   834	7424015051	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM	04/12/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	33.77579	-118.25406	"First floor T.I., new lighting and outlets.  Load is 107A and occupancy load is less than 99, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit Fees are under ""Inspection"", for new circuits and lighting on existing circuits."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19954	19041-10001-04050	6555 W BARTON AVE 100	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.08785	-118.33475	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY. CHANGES INCLUDE REMOVED TRANSFORMER,  SUB PANEL,  AND LIGHTING FIXTURES.<<TI FOR FIRST FLOOR FIRST TIME TENTANT COMMERCIAL OFFICE, SCOPE OF WORK INCLUDES (1) 150A, (1) 100A PANEL, (1) 30KVA  AND (1) 45 KVA TRANSFORMER, T24, TOTAL SQFT'G = 2600 SF>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19955	15041-20000-04111	12039 N HAVANA AVE	91342	7	216B149   379	2611017004	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2015 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.28898	-118.45435	CHANGES TO AN APPROVED SET OF PLANS.  ADDING DEDICATED CIRCUIT FOR PV MONITORING.REFERENCE APLLICATION NUMBER 14041 20000 31028	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19956	13041-20000-19995	8664 N AMESTOY AVE	91325	12	195B133   459	2690019003	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.22819	-118.50683	New Enphase Microinverter PV System for a single family dwelling on a new patio roof.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19957	14041-20001-13634	10309 N LARAMIE AVE	91311	12	204B113   151	2707023011	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.25783	-118.57297	Expedite per customer request11.25 Kw PV1 roof-mounted system with (2) transformerless Power-One Aurora PV1-4.2-OUTD-S-US inverters and (45) Canadian Solar #CS6P-250PX modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19958	14041-10001-06735	12849 W GREENE AVE	90066	11	108B157  1696	4223015025	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	33.98797	-118.42991	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(10) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19959	10041-20000-13274	14539 W BLYTHE ST	91402	6	189B149   311	2210019005	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.21533	-118.44994	PLAN CHECK NEW INSTALLATION OF 69.4KW AND 25KW SYSTEM FOR COMMERCIAL WITH MULTIPLE SERVICES. PERMIT ALSO INCLUDES UPGRADING PANEL TO HIGHER BUS RATING FOR EACH SERVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19960	12041-20000-03186	6380 W WILSHIRE BLVD 15th fl.	90048	5	135B173   874	5088014021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.06348	-118.36826	15th fl. T.I.Energy onlyEmergecy, Fire/ Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19961	16041-10005-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	DELTA 1 CHANGES TO THE APPROVED PLANS. CHANGING LIGHTS IN B3 & B1M CORRIDOR LIGHTING. T-24 ENERGY ONLY.<<<PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT. BUI;DING APPLICATION 16010-10000-04147>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19962	16041-10000-43842	3201 S HOOVER ST 8C2	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	34.02548	-118.28442	Plan check power and energy for 1st time tenant  Total area = 920 sq. ft.    New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19963	14041-10000-07365	900 N WESTERN AVE	90029	13	141B193   110	5535020011	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.08641	-118.30895	tHIS IS TWO STORY NON REQUIERD FIRE ALARM SYSTEM , 17 DEVICES AND ONE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19964	19041-10000-34013	11100-11150 W SANTA MONICA BLVD	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	06/19/2020 12:00:00 AM	ADDRESS	34.04726	-118.44465	PC for T24 only, scope of work is exterior lighting in a plaza, exposed stairways leading to parking garages, and exterior lighting in  parking canopies. Scope of work includes new circuits, and controls. Total affected area is 28,652 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19965	14041-20000-24538	1455 N GORDON ST	90028	13	147A189    89	5545013002	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.09737	-118.32024	Commercial office TI in (E) 1 story commercial office building.  Plan check for energy under 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19966	14041-20001-05049	5920 N WINNETKA AVE	91367	3	177B113   217	2153004013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.17833	-118.57094	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19967	19041-10000-41257	10066 N VANALDEN AVE	91324	12	204B121   430	2729004004	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.2533	-118.54899	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 19.14 KWdc/ 16.82KWac. SCOPE OF WORK IS 58 MODULES (CANDIAN SOLAR CS1H-330MS) WITH MICROINVERTERS (IQ7-PLUS-72-2-US), LEADING TO A NEW 200A LOAD CENTER. MAIN PANEL UPGRADE TO BE SEPRATELLY PERMITTED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19968	10041-20000-13436	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	Firealarm system for Gersten Annex Bld'g.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19969	19041-20000-36638	6300 N RANDI AVE	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.18466	-118.61011	PV2. Plan check for PV roof mounted system, System size: 26.535KW DC, 23.6KW AC with 61 PV Modules and 2 inverter(14.4KW  and 9KW )Note: This is 12 buildings on 1 Plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19970	15041-20000-19062	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Title 24 plan check only.  Total area = 936 sq. ft.  T.I. to existing retail space.  New lighting and recepticles.  Emergency lights and exit signs to remain existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19971	16041-10000-30259	12574 W WINGO ST	91331	7	204B161   484	2537011011	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.2544	-118.4072	PV1. NEW SOLAR SYSTEM FOR AN EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(40)MODULES-SOLAR WORLD 285W (2)INVERTERS-SUNNYBOY-5000-US-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
19972	14041-10000-34840	10327 N VENA AVE	91331	6	204B153   268	2617005020	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.25788	-118.43868	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac. System consists of (1) inverter and (28) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19973	13041-20000-22275	530 W 6TH ST Suite 905	90014	14	129A209    78	5144004012	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.04853	-118.25518	T24 PLAN CHECK FOR EXISTING OFFICE SPACE PART OF A HIGHRISE BUILDING. SCOPE OF WORK ON SUITE 905. 1847 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19974	15041-20000-18184	20529 W TAMARRON LANE	91326	12	216B109   298	2701083020		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	PIN	34.29206464	-118.58179088	RECREATION BUILDING INCL LAUNGE/ POOL BATH ROOMS/ EQUIPMENT ROOMS/ TRELLIS AND ENTRY TOWERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19975	17041-10000-20681	2815 W SUNSET BLVD	90026	13	141A205    48	5402001040	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Info Complete	06/20/2017 12:00:00 AM	ADDRESS	34.08216	-118.27195	Title 24 plan check.  T.I. to existing restaurant.  Existing subpanels to remain with new lighting and receptacle loads.  Lighting area = 1,890 sq. ft. (indoor) + 3,120 sq. ft. (outdoor)       Building permit #16016-10000-25257	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19976	19041-10000-06317	6414 S MCKINLEY AVE	90001	9	105B205  1037	6007015027	M3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	33.98126	-118.26127	New Fire Alarm Sysetm in the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19977	18041-20000-11054	7510 N HAZELTINE AVE	91405	2	186B153    97	2215015012	M1-1, MR1-1, P-1VL, R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Issued	04/04/2018 12:00:00 AM	ADDRESS	34.20701	-118.43985	0$ permit fees due to senate bill 1222Plan check for a PV2 roof-mounted PV system. System size is 99.9 kWac/117.95 kWdc and consists of (3) inverters, (337) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19978	15041-10000-41022	10925 N WILLOWBRAE AVE	91311	12	210B105   202	2722037009	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.26877	-118.59868	PV1 SFD TOTAL SYSTEM SIZE 12 KW AC USING 2 CENTRAL INVERTERS. TOTAL OF 41 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19979	12041-20000-10534	7515 N MASON AVE	91306	3	186B109   409	2113002014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Expired	06/27/2014 12:00:00 AM	ADDRESS	34.20698	-118.57991	Roof mounted PV system for a single family dwelling using 37 Enphase M215 inverters in three strings, upgrade existing panel to 225 amperes, and install a 15 ampere branch circuit in the service panel to supply the locus monitor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19980	19041-20000-50366	15202 W EARLHAM ST	90272	11	123B125   130	4412027022	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.03634	-118.52534	Plan check for PV roof mounted system, PV system size: 12.457KW AC, 14.040KW DC with 39 PV Modules and 39 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19981	13041-10000-12702	523 W 6TH ST 3RD-4TH FLOOR	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	PLAN CHECK FOR POWER AND ENERGY. TI ON 3RD AND 4TH FLOOR OFFICE SPACES FOR NASTY GAL CLOTHING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19982	17041-10000-43496	3458 E WHITTIER BLVD	90023	14	121-5A227 185	5188017002	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	08/12/2020 12:00:00 AM		Permit Finaled	12/31/2020 12:00:00 AM	ADDRESS	34.02687	-118.19926	FULL PLAN CHECK FOR POWER AND ENERGY. TI TO EXISTING MC DONALDS , ADD 1 NEW PANEL CONNECT TO EXISTING SERVICE.,  NEW LOADS > 200A. ((B# 17016-10000-35807))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19983	16041-10000-06848	6384 N BALCOM AVE	91335	5	180B129  1031	2123019019	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	PIN	34.18639686	-118.5203987	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.90KWdc / 3.225 KWac(15)MODULES-SOLARWORLD 260W(15)INVERTER-M215 MICRO-INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19984	19041-10000-03633	2121 S AVENUE OF THE STARS 1st FLR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.05554	-118.41342	TI IN EXISTING RESTROOMS ON THE 1ST FLOOR. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-02778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19985	16041-10000-42741	1417 N NORTH MAIN ST	90012	1	135A217    58	5409005033	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			Reviewed by Supervisor	01/17/2017 12:00:00 AM	ADDRESS	34.0652	-118.23093	Full plan check to exsiting building. Renovation to wherehouse to commercial office/retail space. New 800 Amp service which feeds two buildings located in the same lot. Total sqft = 6632.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19986	19041-20000-50483	13263 N WHEELER AVE UNIT 15	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS(ENPHASE IQ7PLUS)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19987	11041-10000-11167	5331 E HUNTINGTON DR NORTH Bldg # 1	90032	14	145-5A237 252	5309017036	(T)[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Apartment			06/01/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	01/24/2012 12:00:00 AM	ADDRESS	34.09124	-118.16464	New fire alarm with 15 devices for Building 1 (out of 3 buildings).  Building 2 PCIS # is :  11041-10000-11171 and Bilding 3 PCIS # is: 11041-10000-11173	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19988	15041-20000-05964	1608 E 33RD ST	90011	9	115-5A213 150	5117009010	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	04/25/2015 12:00:00 AM	ADDRESS	34.01112	-118.24598	Installation of new roof mounted solar PV microinverter array.  Total system size = 3.44 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19989	13041-10000-35574	1317 S HOPE ST	90015	14	126A207   172	5134011006	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	02/07/2017 12:00:00 AM		Issued	02/07/2017 12:00:00 AM	ADDRESS	34.03907	-118.26618	PLAN CHECK FOR POWER AND ENERGY FOR NEW 6 STORY , 38-UNIT ) APARTMENT COMPLEX AND RETAIL . MIXED USE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19990	15041-10000-05016	13251 W VENTURA BLVD	91604	2	165B157   839	2375017007	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.14656	-118.42141	Title 24 plan check only.  Total area = 2570 sq. ft.T.I. to existing restaraunt space.  1 New 100 A panel + lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19991	17041-10000-40168	825 S HILL ST 1st level	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	01/14/2021 12:00:00 AM	ADDRESS	34.04392	-118.25657	First tenant in office spacefull plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19992	16041-20000-39215	11336 N MODENA LANE	91326	3	213B109   218	2701053037	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.27825	-118.58304	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
19993	18041-20000-19574	5990 N SEPULVEDA BLVD 300 & 330	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.17911	-118.46588	Tenant improvement for reception and commercial office space.  Plan check for energy. Total area: 1307 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19994	14041-20000-33475	2324 N MANDEVILLE CANYON ROAD	90049	11	141B133   401	4493004006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.0783	-118.50128	Permit fee $0.00 by state senate bill #1222Roof mounted PV system with total system size 22.86 KW.  Some modules are existing to be remained.  Note: Mfr's cutsheets of the existing PV module will be submitted by the applicant before plans get assigned.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
19995	14041-10000-01270	380 WORLD WAY T-26-SLTG	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	pc for energy only. SIGN LIGHTING. TWO SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19996	13041-20000-33115	13263 W VENTURA BLVD	91604	2	165B157   828	2375017005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.14662	-118.42179	T24 FOR EXISTING OFFICE SPACE. TOTAL SQRFT 2400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19997	18041-10000-47144	7422 W 80TH ST	90045	11	099B157   286	4114014017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	33.96364	-118.42711	INSTALLATION OF TWO NEW AC COUPLED BATTERY STORAGE, TESLA. IN A SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 27KWH AND 10KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
19998	19041-10001-23651	6201 E STRICKLAND AVE	90042	14	159A231   299	5482007018	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	34.12826	-118.18489	PLAN CHECK ONLY. Supplemnt to an approved set, change includes relocating main panel. under delta 1. permit under main application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
19999	14041-10000-06217	5250 N HERMOSA AVE	90041	14	163-5A225 142	5669023006	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	34.14269	-118.20757	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20000	18041-10000-19309	7660 W BEVERLY BLVD	90036	4	138B177   453	5512002010	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Apartment			05/25/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.07595	-118.35668	POWER PLAN CHECK ONLY. SCOPE INCLUDES  ADDITON OF  WASHER/DRYER BRANCH CIRCUIT TO EXISTING 282 UNITSAND RVISIONS TO 22 FEEDERS DUE TO THE NEW LOAD CALCS.  B#18016-10000-14907	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20001	12041-10001-02213	7508 W MELROSE AVE	90036	5	141B177   659	5526017027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Approved	11/20/2012 12:00:00 AM	PIN	34.08337436	-118.35354775	Plan check power and energy for new Fresh & Easy market with new 2000A service. Existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20002	17041-10000-32823	10900 W WILSHIRE BLVD 10,11,14th-floors	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.05848	-118.44419	PLAN CHECK FOR T24 ONLY, RENOVATION OF 6 EXISTING RESTROOMS ON LEVELS 11, 12 AND 14 : MENS AND WOMEN'S	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20003	18041-20000-04338	6857 W CAMROSE DR	90068	4	151-5A185 335	5549028031	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.10895	-118.33886	pv1install roof mounted pv system sized 3kw with battery back up interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20004	12041-10000-11280	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Public Safety Only			05/16/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20005	17041-10000-11015	8970 W CADILLAC AVE	90034	10	126B169   792	4302017007	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.04078	-118.38691	Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 5.2 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20006	11041-10000-12740	7303 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/27/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of  1 elevator unit in admin. West low rise Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20007	19041-20000-17841	14912 W WYANDOTTE ST	91405	6	186B149   765	2221021005	RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			05/13/2019 12:00:00 AM	01/06/2020 12:00:00 AM		Permit Finaled	12/23/2020 12:00:00 AM	ADDRESS	34.20281	-118.45791	800A 240/120V 1ph-3w service, distribution, power, and lighting for new construction.  Note: Building application has been generated under 16010-20000-05424.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20008	19041-10000-09341	8943 N LINDLEY AVE	91325	12	195B125   277	2769015033	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.23303	-118.52753	**ePlan** Permit fee  $2  per AB 1414 / SB 1222. PV1. PC FOR NEW ROOFTOP SOLAR SYSTEM CONSISTS OF 45 MODULES (Q-CELL 305), 45 OPTIMIZERS (SE P320) AND 1 INVERTER (SE11400A-US). SYSTEM SIZE IS 13.725kWdc AND 11.6kWac. PANEL DERATE (200A TO 175A) TO BE PERMITTED ON A SEPERATE PERMIT (EXPRESS)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20009	15041-10001-37105	18957 W VENTURA BLVD	91356	3	174B121   406	2163020019	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM			PC Approved	11/10/2015 12:00:00 AM	ADDRESS	34.17263	-118.54646	CHANGE TO APPROVED SET OF PLANS. CHANGE EMERGENCY FIXTURE TO REGULAR. ADDITION OF BUG EYE FIXTURE INSTEAD. LOWER LIGHTING LOAD. ALL CHANGES CLOUDED. DELTA 1 REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20010	13041-20000-31275	10526 W DUBNOFF WAY BLDG G	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	05/22/2014 12:00:00 AM		Issued	05/22/2014 12:00:00 AM	ADDRESS	34.18656	-118.36106	PC FOR POWER. NEW 1600A SERVICE AND DISTRIBUTION. BUILDING G OF SERIESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20011	19041-10000-12795	500 S MANHATTAN PL	90020	4	135B193   668	5503018008	R4-2	Central	Wilshire	Greater Wilshire		2117.04	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Issued	06/13/2019 12:00:00 AM	ADDRESS	34.06513	-118.31018	pc for new Fire Alam system. 1 Panel and 87 FA devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20012	14041-10000-12724	8525 N TELFAIR AVE	91352	6	192B169   321	2632023047	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.22421	-118.384	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL  14514 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20013	12041-10001-26341	123 W ANN ST PV2	90012	1	135A217    35	5409005028	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.06552	-118.23177	Delta-1 changes to original approved set.  Removing some panels from indoor to outdoor.  Relocated panels are listed for outdoor use. Original Description:New 77.2 kw roof mounted PV system for a comercial BLDG. (PV2)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20014	15041-20001-39560	4776 N NOMAD DR	91364	3	168B113   189	2175039004	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.1578	-118.56737	Expedited per customer request.PV1. Install roof mounted PV system sized 15 kW. Interconnected with main service panel. (50) Sunpower SPR-327 Modules(3) SMA SB5000 TL Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20015	13041-20000-35999	7483 W PALO VISTA DR	90068	4	156B177   404	2427013007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	PIN	34.12315083	-118.35867799	PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20016	15041-10000-21724	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	CLARIFY SUITES. C130, 145, AND CONCOURSE ON ARCHITECT BUT DIFFERENT FROM GIVEN DESCRIPTION OF SUITE A, B, AND C. TOTAL AREA IS 2316 SQ. FT.PC FOR POWER AND ENERGY. TI FOR MEDICAL KAISER PERMANTE. HIGHRISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20017	14041-10000-01287	818 W 7TH ST 6th FL	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.04895	-118.25943	TI in office suite for future data center.  Installation of CRAC units and panels for future loads.  Changes to lighting on existing branch circuits in space.  Plan check is for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20018	11041-10000-06903	13450 W MAXELLA AVE STE G100	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	33.98645	-118.44148	T.I. FOR DSW.  REMODELING BATHROOM AND OFFICE AREA.  TITLE 24 PLAN CHECK ONLY.  NO EMERGENCY LIGHTING; adding three luminaires  after a wall was removed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20019	14041-10000-03090	4507 N ATOLL AVE	91423	4	165B157    64	2360027021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Expired	04/05/2016 12:00:00 AM	ADDRESS	34.15241	-118.42053	PV1, Install 7.25 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE6000A-US-ZB-U(29) Modules: YINGLI YL250P-29b	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20020	11041-10000-19883	644 S MAIN ST	90014	14	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM			PC Approved	09/19/2011 12:00:00 AM	ADDRESS	34.04423	-118.25077	T-24 lighting plan check for remodeled restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20021	14041-20000-09011	18325 W LINNET ST	91356	3	171B125   326	2161022027	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	34.16583	-118.53247	Roof mounted PV system Optimizer, system size 4.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20022	16041-10000-16885	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Closed	07/23/2021 12:00:00 AM	ADDRESS	34.05715	-118.41482	CORE AND SHELL OF THE ELECTRICAL SYSTEM FOR IMPROVEMNTS  FOR AN EXISTING HOTEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20023	17041-10001-32046	11677 W SAN VICENTE BLVD #315	90049	11	132B145   497	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.05404	-118.46492	Supplemental change to light fixture type.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20024	16041-20000-20812	6700 W MELROSE AVE	90038	5	141B181   643	5524016001	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.08333	-118.33986	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 3246.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20025	17041-10000-03142	2049 S CENTURY PARK EAST 7TH	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY ONLY. T.I. IN BATHROOM FOR MORE ACCESSIBILITY ON THE 7TH FLOOR. TOTAL AREA IS 410.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20026	14041-10001-05209	12421 W RYE ST	91604	2	165B165   179	2364016017	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.1514	-118.4039	Expedited plan check per applicant request.  (((PV1.  Install 6 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE5000A-US-ZB-U.  24 modules: Trina Solar TSM-250PA05.18)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20027	14041-20001-35132	7463 N VARNA AVE	91605	2	186B157   249	2328027020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	34.20651	-118.42487	"Fee for expedite only.12.18.2014 - Plan check for modification to approved set - Change interconnection of solar system to DWP Feed-In-Tariff. Recheck interconnection and obtain planning clearance. Original permit pulled under permit #13041-20000-23548.See comments for planning clearance details.[PV2 100KW 3 PHASE SYSTEM. 400 MODULES AND 1 INVERTER. ""$0 permit fee is due to the 2012 Senate Bill No. 1222""]"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20028	16041-10000-06827	10469 N SAN FERNANDO ROAD	91331	7	207B161   433	2620028006	M2-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.26046	-118.41643	PC FOR POWER ONLY FOR A NEW 800A SERVICE UPGRADE AND MAIN SWITCHBOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20029	16041-10001-02674	6312 S 7TH AVE	90043	8	105B189  1205	4007012025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	33.98255	-118.32439	Revision to approved set. Qty of modules reduced to (14). Permit under 16041-10000-02674.***PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.6KWac. (15)MODULES-SILEVO # TRIEX U290 BLACK(1)INVERTER-ABB #PVI-3.6-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20030	10041-10000-17700	249 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			Corrections Issued	09/19/2010 12:00:00 AM	ADDRESS	34.0498	-118.22618	Solar voltaic system installed on the roof of the building.  Consists of  6 modules,  6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20031	16041-20000-07492	11864 N FELLOWS AVE	91340	7	216B157    64	2524004014	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.28523	-118.42081	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (38) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20032	18041-20001-12224	500 S MATEO ST 102	90013	14	127-5A217  67	5163018005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.04146	-118.23294	11/27/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Changes have been made to the lighting floor plans. Lighting control panel and inverter and now being used.*****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 5,327 sq. ft.Note: Building application has been generated under 17014-10000-06345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20033	14041-20001-17631	1391 W SUNSET BLVD	90026	1	138A211    26	5406012038	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Issued	03/04/2015 12:00:00 AM	ADDRESS	34.07391	-118.25153	[[[[2/27/14  Changes to an approved set of plans. delta 1 changes .no new loads added. removing 2 existing panelboards and relocation existing loads into 5 new panelboard]]]]]].*****Previous Work Description*****INTERIOR TENANT IMPROVEMENT, CHANGE OF USE FROM (E) RETAIL TO RESTAURANT (108 OCCUPANT LOAD).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20034	15041-10000-19890	707 N COLE AVE	90038	13	141B185   539	5533034011	C4-1XL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.08372	-118.33005	Methane gas detection system with (1) control panel,  (4) fire alarm devices, and (22) control devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20035	11041-20000-20236	13307 W MOORPARK ST	91423	2	165B157   295	2360013024	[Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.1505	-118.42312	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20036	14041-10000-11558	5816 N WHITSETT AVE	91607	2	174B165   155	2340015016	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			05/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.17612	-118.40506	plan check for power and energy. not methane. 8 typical units.bldg#08010-20-00630: NEW FOUR STORY 23 UNITS APT BLDG.OVER TWO LEVELS TYPE IA PARKING GARAGE <35% DENSITY BONUS FOR 6 ADDITIONAL DWELLING UNITS WITH TWO VERY LOW INCOME UNITS AND REDUCED PARKING>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20037	17041-20001-30155	7943 N WOODLEY AVE	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.21559	-118.48387	4/30/2018changes to an approved set of plans.  changes noted delta 1 and delta 2.  changes include different inverters and interconnections.  (7) new inverters, (3) 33.3kw and (4) 20kw. No change in system output 180kw.((((Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size 960 kWac. Ground-mounted portion of the system is 180 kWac and consists of (3) inverters, (512) modules, and (1) load center.Note: Roof-mounted portion of the system has application number 17041-20000-30147.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20038	16041-10000-17527	511 S RAMPART BLVD	90057	1	135A201   137	5155020004	R4-1	Central	Westlake	Rampart Village		2087.20	Electrical	Electrical	Apartment			05/18/2016 12:00:00 AM			PC Approved	05/23/2016 12:00:00 AM	ADDRESS	34.06347	-118.28095	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING APARTMENT BUILDING. SCOPE INCLUDES REPLACE OLD FLUORESCENT LIGHTS WITH LED LIGHT FIXTURES IN THE 1ST FLOOR AND 2ND FLOOR HALLWAY. TOTAL AFFECTED AREA IS 4345 SQ. FT.NOTE: PERMIT PAID UNDER PCIS#16041-10000-06413	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20039	18041-20000-47659	12759 W VAN NUYS BLVD	91331	7	210B161    41	2533019032	[Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.27548	-118.41208	"Plan check for new fire alarm system for Primary Care Clinic ""Medical Clinic"", Total fire alarm devices: 100 with 1 FACP."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20040	19041-10000-52089	2455 N HORSE SHOE CANYON ROAD	90046	4	153B173   339	5565011001	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	01/27/2020 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.11546	-118.37772	$2.23 due to AB1414 (E-PLAN)NEW PV1 ROOF-MOUNTED AN EXISTING SERVICE OF 400 AMPS. INSTALLATION INCLUDES 39 MODULES (Sunspark Technology SST-310M) , 39 OPTIMIZERS (SolarEdge Technologies P320Power Optimizer), AND 1 CENTRAL INVERTER (SE10000H-US)SYSTEM SIZE: 12.09 KW DC; 10 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20041	17041-10000-22584	6801 S PARK TER 100	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	33.97698	-118.39328	PC FOR POWER AND ENERGY IN (E) MEDICAL OFFICE. INSTALLING NEW X- RAY MACHINE WITH NEW PANEL AND CIRCUITS. INCLUDING NEW LIGHTS IN X-RAY ROOM. TOTAL  AFFECTED AREA 309 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20042	11041-20000-08086	127 S SAN VICENTE BLVD Bulletin-39	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 39	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20043	12041-20000-10672	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	BULLETIN # 165-T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20044	18041-20000-18403	1082 W 30TH ST	90007	9	121-5A201 139	5039019045	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			05/17/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	34.02731	-118.28621	Remodel of (E) two-story apartment building.  Plan check for Title 24 Part 6 for common area corridors.  Renovation work in dwelling units included in scope of permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20045	18041-10000-19502	620 W 135TH ST	90248	15	078B201   103	6132005021	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.90897	-118.28563	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20046	19041-10000-32645	2510 N BANYAN DR	90049	11	141B133   162	4492025006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.0819	-118.50678	PV 1 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER TIED TO A DC COUPLED BATTERY SYSTEM. (16) MODULES, (16) OPTIMIZERS, 7.6 INVERTER, AND RESU 10H DC BATTERY. TOTAL SYSTEM SIZE IS 7.6KWAC/5.280 KWDC. SUPPLEMENTAL PERMIT FEES UNDER PERMIT APPLICATION # 17041-90000-44376	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20047	18041-10000-44957	6323 W 80TH ST	90045	11	099B165   483	4109001026	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.96715	-118.39658	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20048	13041-10000-35349	1015 S CROCKER ST STE Q16	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH FLUORESCENT FIXTURES. 836 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20049	19041-10000-16908	10740 W SANTA MONICA BLVD	90025	5	129B153   365	4321004005	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	03/21/2022 12:00:00 AM		Issued	03/21/2022 12:00:00 AM	ADDRESS	34.05094	-118.43307	New 800A 240/120V 3ph-4w service, distribution, power, and lighting for (E) building renovation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20050	17041-10000-38626	15060 W VENTURA BLVD #  130	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.15287	-118.46147	CHANGE OF USE FROM OFFICE TO COFFEE SHOPPLAN CHECK IS FOR TITLE 24B#17016-40000-23896	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20051	19041-10000-00282	9171 N DE SOTO AVE Suite E	91311	12	198B109   225	2746009048	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.23778	-118.5888	"FULL PLAN CHECK FOR FIRST TIME TENANT IN SUITE ""E"" - PLAN CHECK INCLUDES CONNECTING TO EXISTING 800A DISTRIBUTION BOARD RATED AT 120/208V. TOTAL NEW CONNECTED LOAD IS APPROX 150A WITH A TOTAL AFFECTED AREA = 1361 SF"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20052	16041-10001-23791	1023 S ABBOT KINNEY BLVD	90291	11	109-5A143 439	4239021027	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	33.99219	-118.47181	PC FOR CHANGES TO APPROVED SET OF PLANS. UPDATED LIGHTING LAYOUT AND T24 DOCUMENTS. THIS REMAINS ENERGY ONLY PC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20053	19041-10000-04077	17383 W SUNSET BLVD	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			02/04/2019 12:00:00 AM			PC Approved	02/04/2019 12:00:00 AM	ADDRESS	34.03917	-118.55529	T24 PLAN CHECK FOR OFFICE TI/REMODEL TO 2ND FLR OF EXISTING COMMERCIAL BUILDING, TOTAL SQFT'G = 2654 SF, NEW LIGHT AND POWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20054	15041-20000-18437	14885 W EL CASCO ST	91342	7	225B149   436	2505029005	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.30989	-118.45713	Plan check for PV roof mounted system.  System size 8.9kW with 35 modules and 35 microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20055	19041-10000-24474	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.16935	-118.53104	NEW FIRE ALARM SYSTEM IN A MEDICAL OFFICE BUILDING. SYSTEM CONSIST OF 1 FACP, 1 COMMUNICATOR, 1 ANNUNCIATOR AND 131 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20056	18041-20001-17050	9418 W BOLTON ROAD	90034	5	126B165    55	4309013009	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	34.04518	-118.39388	Revision to approved set of plans.  Change of service equipment detail from 400A bus with 400A main to separate 200A bus sections with 200A main and derated 150A main.  Load calculations provided to justify derated main breaker rating.(((Plan check for PV roof mounted system, System size: 15.12kWac with 42 AC Modules connected to 400A MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20057	16041-10000-05361	2029 S CENTURY PARK EAST suite 3200-3300	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, PC FOR ENERGY ONLY. T.I. FOR OFFICE SPACE ON 32ND & 33RD FLOORS OF A HIGH RISE BUILDING. SCOPE INCLUDES LIGHTS, RECEPTACLES, AND 1 NEW 100A PANEL. TOTAL AFFECTED AREA IS 45,625 SQ. FT. .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20058	10041-10003-10084	530 W 27TH ST	90007	9	121-5A203 130	5123018019	(T)(Q) C2-2, D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.0269	-118.27607	Delta 4 modification to previously approved set of plans as shown on pages FA-03 and  FA-07.  No other items within scope of work.  See prevously approved set of plans for all other work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20059	19041-10000-41089	5155 W SANTA MONICA BLVD	90029	13	144B193   686	5537015031	C2-1D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	34.09096	-118.3015	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20060	16041-10000-30626	6600 N TOPANGA CANYON BLVD #2044	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE (sPACE #2044). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1860 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20061	13041-20000-35882	447 N FAIRFAX AVE	90048	5	141B177  1285	5527031018	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	PIN	34.07945639	-118.36178388	T24 FOR EXISTING RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20062	15041-20001-35941	442 N SWEETZER AVE	90048	5	141B173  1245	5514004034	R1-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.07945	-118.36988	Expedited per applicant request.Plan  check for PV roof mounted system. System size: 3.8kW with 16 modules and 1 inverter(3.8kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20063	16041-20001-25960	1255 N BUNDY DR	90049	11	141B141   159	4493028021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.08224	-118.48357	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 11.7kW with 41 modules and 41 microinverters(Enphase)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20064	19041-10000-45422	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM			PC Info Complete	11/05/2019 12:00:00 AM	ADDRESS	34.05069	-118.24861	T-24 PLAN CHECK FOR A TI TO BASEMENT LEVEL STAIRS . SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 180 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20065	17041-10000-36979	1099 S WESTWOOD BLVD	90024	5	132B149    54	4363018014	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.06114	-118.4456	PC for T24 only for restuarant TI. Installing new panel, circuits, equipment and relocating circuits. Total of 5411sqft. Installed load under 400A. B# 17016-10000-20938. INSPECTOR TO VERIFY WATTAGES OF 'DF' FIXTURES DO NOT EXCEED WATTAGES SPECIFIED ON LTI-01 PG5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20066	19041-10000-14156	605 W WILSHIRE BLVD	90017	14	129A209    76	5144005021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	05/23/2022 12:00:00 AM	PIN	34.0484292	-118.25607403	ENERGY PLAN CHECK FOR A  CHANGE OF USE FROM OFFICE TO RESTAURANT. SCOPE INCLUDE  NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 2152-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20067	15041-10001-31804	11845 W OLYMPIC BLVD 1100	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	PIN	34.03325831	-118.45191172	01/14/16Changes to an approved set. All changes are clouded/bubbled. Changes includes adding/removing lighting fixtures, adding a 15KVA tranformer, and adding 1 new 100A panel for emergency lighting. Total affected area is changed from 10654 SQ. FT. to 11445 SQ. FT. (((((T-24, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. CONNECTED LOAD <400 AMPS. TOTAL SQ. FT. 10654	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20068	15041-10000-34826	338 S WESTERN AVE	90020	10	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.06777	-118.30889	ALTERATIONS IN A SUSHI  RESTAURANTPLAN CHK IS FOR TITLE 24. Inspection fees have been paid under permit# 15041-10000-32631 and 15041-10001-32631	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20069	17041-20001-30280	3616 S TROUSDALE PKWY	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.01983	-118.28534	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, DELTA 2 CLOUDED CHANGES ONLY. INSTALLATION OF A EATON GENERATOR QUICK CONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20070	14041-20000-01721	3575 N WONDER VIEW DR	90068	4	159B185    51	5577004008	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.13282	-118.33656	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20071	19041-20001-09831	327 S HOOVER ST EV1	90020	13	136-5A201 207	5501022007	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			04/09/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.06799	-118.2845	Plan check per inspector correction notice.  (((Install 11 EVC1 200 amp panel1 200 amp stat meter1 200 amp disconnect1 120v 20amp cir3 240v 40amp cir)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20072	19041-20000-16865	1377 N SERRANO AVE 3RD FLR	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.0965	-118.30717	TI to 3rd floor of (E) commercial office building.  (E) distribution equipment with new branch circuit wiring for power and lighting.  Connected load exceeding 400A.  Plan check for power and energy. total square footage = 19,878 sf	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20073	13041-10001-03751	5000 N DOMAN AVE	91356	3	168B125    27	2181022016	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.16066	-118.52793	changes to approved set of plans. REC 245 to 250. Fees charged per applicant request. PV1 MICRO INVERTER two STORY HOUSE. [MIRCRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20074	16041-10000-34550	10708 W VANOWEN ST	91605	2	180B177    10	2414024030	M1-1VL, P-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.19375	-118.3645	PC for energy only. Remove HID fixture and replace with new LED fixture. Total sqft = 9600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20075	16041-10001-21251	10012 N COZYCROFT AVE	91311	12	204B109   464	2741024009	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.25206	-118.58183	SUPPLEMENTAL TO AN APPROVED SET ADDING AN ADDITIONAL  (8) MODULES: HYUNDAI HIS-S260RG 260W (8) MICROINVERTERS: ENPHASE M215-60-2LL-S22. SYSTEM SIZE 4.3KW.  PERMIT FEE IS $0 DUE TO SENATE BILL 12222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20076	16041-20002-08273	8303 N LESTER LANE	91304	12	192B093   457	2005017037	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.21944	-118.63972	PLAN CHECK ONLY FOR A PV SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.175KWdc / 9.250KWac.(37)MODULES-SOLARWORLD SW275W(37)MICROINVERTERS-ENPHASE M250-60-2LL-S25NOTE: PERMIT PULLED UNDER PCIS#16041-90000-08273((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20077	16041-20000-02607	201 S FIGUEROA ST	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.05643	-118.25357	Plan check for Title 24 only Project site is an existing commercial building. Project scope is outdoor courtyard lighting. Total lighting area = 3,360 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20078	13041-20006-29804	1500 W PACIFIC COAST HWY A-L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			03/29/2016 12:00:00 AM			PC Approved	03/29/2016 12:00:00 AM	ADDRESS	33.79072	-118.2857	3.29.2016 - Plan check for modifications to approved set. Change witch fixtures have emergency backup power inside Recreation building. Recheck emergency photometrics.===3.7.2016 - Plan check for modifications to approved set. Recreation building indoor lighting design altered. Recheck to 2008 title 24.===02-18-2016 Change to approved set of plans. Changes include panel load(Methane load, exhaust fan load for Methane Detection System) UL listed panel for methane Detection System are not part of the plan. Methane Detection Panel are attached as cutsheet for each building (13 Buildings)Changes apply to Delta 13 only. Note: Methane Detection System Application reffer to 15041-10000-12870****************Previous work description****************************************************************************************************************************************************************************************************BUILDING A:   NEW APARTMENT COMPLEX CONTAINING 12 SEPERATE BUILDINGS UNDER THE SAME ADDRESS. (2) 4000A SERVICES. PER APPLICANT REQUEST SUBMITTED AS ONE LUMP SUM. METHANE ZONE, HAS METHANE REPORT.Note: Variance to separate Methane Detection System has been filed.Permit Bld. B is under 14041-20000-06842Bld. C is under 14041-20000-06845Bld. D is under 14041-20000-06846Bld. E is under 14041-20000-06848Bld. F1 is under 14041-20000-06850Bld. F2 is under 14041-20000-06875Bld. G is under 14041-20000-06852Bld. H is under 14041-20000-06853Bld. I is under 14041-20000-06854Bld. J is under 14041-20000-06856Bld. K is under 14041-20000-06858Bld. L is under 14041-20000-06859Bld. Recreation is under 14041-20000-06860*************************************************************************************************************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20079	13041-10000-27658	20721 W MARILLA ST	91311	12	201B109   154	2748004040	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.24819	-118.58497	PV2.  Install 125.568 kW DC roof-mounted solar array, interconnect with existing electrical distribution system.  384 modules: SunPower SPR-327E-20-WHT-D.  Transformed commercial inverter: Solectria  PVI-100KW-PE$ 0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20080	15041-10000-16937	8737 N WAKEFIELD AVE	91402	14	127-5A215 420	5163023001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.22835	-118.4468	PV 2 ROOF MOUNTED SYSTEM. 16 PV MODULES AND I INVERTER. TOTAL SIZE 4.16KW(16) HANWHA Q-CELLS, Q.PRO(1) SOLAR EDGE, SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20081	14041-20001-12381	16772 W MONTE HERMOSO DR	90272	11	135B117    69	4431031011	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.06887	-118.55351	Fee for expedite only.*****Roof mounted PV system with system size 7.76 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20082	14041-20000-26079	17360 W HAMLIN ST	91406	6	180B129   774	2229026004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.18835	-118.51197	PV1.  Install 3.9 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20083	13041-10000-35291	5161 N LANKERSHIM BLVD STE #130	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.16452	-118.37469	"T24 PART 6 ENERGY FOR (E) OFFICE SPACE, LOW-RISE. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING WORK IS APPROX. 2275 SQ FT. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.""COMPLY WITH DEPARTMENT ORDER effective date10/28/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20084	15041-10000-23151	1550 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.09932	-118.32644	PC FOR POWER AND ENERGY. FIRST TIME TENANT. FITNESS BUILDING. TOTAL AREA 38243 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20085	15041-20000-31676	10831 N AQUEDUCT AVE	91344	12	207B141   131	2662021014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.26747	-118.47408	Plan check for PV roof mounted sytem. System size: 7.6kW with 31 modules and 1 inverter(7.6kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20086	19041-10000-32987	123 S ALVARADO ST	90057	13	135A205    14	5154008010	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/07/2019 12:00:00 AM	ADDRESS	34.06615	-118.27088	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20087	17041-20000-13276	16633 W VENTURA BLVD ste 1040	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.15823	-118.49571	ti to an existing commercial buiding (high rise).  adding new lighting new controls to existing panels.  plan check for energy  and em lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20088	17041-10000-04278	4401 S CRENSHAW BLVD	90008	8	111B185   131	5013013013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.00332	-118.33201	REPLACE SITE LIGHTING ATTACHED TO THE BUILDING. BUILDING IS LADBS JURISDICTION. PARKING LOT IS UNDER SEPARATE JURISDICTION. TOTAL AFFECTED AREA IS 9900 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20089	14041-10000-15682	685 S NEW HAMPSHIRE AVE 1-177	90005	10	132B197   143	5094008004	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Closed	06/02/2016 12:00:00 AM	ADDRESS	34.06041	-118.29315	Temporary power for construnction.  Submittal + permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20090	15041-10000-04889	1414 N CATALINA ST	90027	13	147B197   848	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Expired	04/28/2017 12:00:00 AM	ADDRESS	34.09716	-118.29486	Installation of exterior building facade lighting.  Title 24 plan check only.  Total area = 6,104 sq. ft. (proposed lighting area of illumination)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20091	11041-20000-12951	19600 W PLUMMER ST	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.2426	-118.5602	PLAN CHECK 800A SERVICE AND EQUIPMENT FOR TEMP POWER CONSTRUCTION FOR NEW MIXED-USE  BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20092	11041-10000-22369	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Expired	11/15/2013 12:00:00 AM	ADDRESS	34.05436	-118.25543	New and replacement fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20093	16041-20000-01280	9255 N CORBIN AVE	91324	12	198B117   150	2761001075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.23837	-118.56248	Tenant improvement to 21,360 sq. ft. commercial office space in (E) single-story building.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20094	12041-10000-27263	13214 N INGRES AVE	91344	12	225B133   200	2602001013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.31019	-118.50365	PV1 10.29KW ROOF-MOUNT SUNNYBOY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20095	12041-10000-01411	4461 N HAYVENHURST AVE	91436	5	165B137    76	2284010024	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.1519	-118.49296	Plan check 12.22KW roof mounted photovoltaic system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20096	18041-10001-13112	1552 W ROCKWOOD ST	90026	13	135A207   285	5159013016	RD1.5-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	34.06355	-118.26143	EXPEDITED PER APPLICANTS REQUEST. PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 46.5 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20097	11041-10000-15782	680 S SANTA FE AVE	90021	14	124-5A217 169	5164018004	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.03555	-118.23008	T.I.  One story warehouse was damaged during a fire.  Work to be done is to install a 600 amp service, 2 panels, and to re-wire the entire area including lighting.  Plan check is for energy and power	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20098	18041-10000-33482	2029 S CENTURY PARK EAST # N1000	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN AN EXISTING OFFICE AREA IN SUITE # N1000. T-24 ENERGY ONLY.  2295 SQ FT.BLDG PERMIT 18016-10000-21382	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20099	13041-10000-35549	1015 S CROCKER ST STE #P08	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 1467 SQ FT. REPLACING TOTAL OF 5 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20100	14041-20000-34399	523 W 6TH ST 1ST FLOOR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. ADDING LIGHTING AND BRANCH CIRCUITS TO EXISTING PANNEL. PLAN CHECK FOR TITLE 24 ONLY AND EMERGENCY LIGHTING. TOTAL SQFT. 634	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20101	16041-20001-36924	11490 N ORUM ROAD	90049	5	144B145   223	4369003008	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.08824	-118.46442	Electrical permit fees paid under building combination permit 15010-10000-02111.9.13.2017 - Plan check for modifications to approved set. Add panels J and H1. Show LCPs 1-7 on SLD and on floor plans. Reduce LCP breaker sizes to 30A. Show location of panels P and G on site plan. Relocate condensing units, feed from panel J.Electrical permit fees paid under building combination permit 15010-10000-02111.======Full Plan check for a new 4 story single family residence. New service size rated at 800 Amps 208Y/120V 3 phase 4 wire. All new electrical equipment. Total sqft approx 16824. bldg app # 15010-10000-02111	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20102	15041-10000-34507	707 W WILSHIRE BLVD 3625	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	Title 24 plan check only.  Total area = 1,766 sq. ft.    T.I. to existing commercial highrise office space.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20103	15041-20002-02659	12500 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/31/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	EXPEDITE PERCUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20104	17041-30000-03189	8600 N GLENOAKS BLVD 1-60	91352	2	192B177    43	2404009013	(Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.03	Electrical	Electrical	Apartment			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.22667	-118.36307	Installation of fire alarm system in new 3 story 60 unit apartment building.  Total system size = 190 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20105	11041-10000-16556	749 S CLOVERDALE AVE 1-6	90036	4	132B181   177	5089003034	[Q]R4-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.06097	-118.34693	New 6 unit apartment building.  3 story building.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20106	14041-20001-33840	19706 W TRAMMELL LANE	91311	12	210B117   403	2701054021	RE20-1-H-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.27203	-118.56301	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 11.4kW. Ungrounded system. Using 400W power optimizers.38  295W pv modules across two strings (19+19).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20107	13041-10000-11069	19346 W VICTORY BLVD	91335	3	180B117   922	2131012009	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.18638	-118.55524	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 10.54KW.  THREE STRINGS AND TWO INVERTERS.  [MODULES: TRINA SOLAR # TSM--245PC05 ||| INVERTER: SOLAREDGE # SE6000A-US AND  # SE3800A-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20108	11041-20000-20551	15544 W CABRITO ROAD	91406	6	189B145   206	2654040010	M2-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM			PC Approved	09/27/2011 12:00:00 AM	ADDRESS	34.21708	-118.47137	Commercial space.  Installing new ight fixtures through out the space due to fire damage repair.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20109	15041-10000-34899	458 E MONTECITO DR	90031	1	145-5A225 134	5303005024	[Q]R1-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.09395	-118.20166	PV1, ROOF MOUNTED SOLAR SYSTEM TOTAL SIZE 2.91 KW-DC. (11) MODULES AND (1) INVERTER. (11) KYOCERA #KU2656ZPA(1) SOLAREDGE #SE3000A-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20110	10041-10000-24500	18660 W VENTURA BLVD Level 1	91356		174B121   601	2161008001	C2-1VL		Encino - Tarzana	Tarzana	YES		Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM			PC Approved	12/08/2010 12:00:00 AM				outdoor lighting plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20111	18041-20000-44096	10742 W RIVERSIDE DR	91602	4	165B177    93	2423005014	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			11/16/2018 12:00:00 AM	03/27/2019 12:00:00 AM		Issued	03/27/2019 12:00:00 AM	ADDRESS	34.15208	-118.36511	Plan check for power and energy. Project site is a 3-story, 12-unit apartment building. Work includes a 600 amp service and a total lighting area of 9,292 sq. ft.Note: Building permit has been issued under 17010-20000-01517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20112	17041-20000-00512	15901 W FOOTHILL BLVD	91342	7	228B141   157	2603011***	RD2-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.3214	-118.47707	PV1.  Install 6.2 kW roof mounted grid tied PV system.  (18) AC modules.  AC module/microinverter standard plan is being used.   In accordance with the requirements of 2014 NEC 690.12, array conductors extending more than 10' from the array will be disconnected from the array as the AC modules inherently qualify for the rapid shutdown feature (documentation attached to approved standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20113	14041-20000-06374	7279 W CHETWOOD DR	91042	7	207B197   321	2553002021	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.26605	-118.29056	PV2 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20114	19041-20000-30315	21400 W NASHVILLE ST	91311	12	210B105   180	2722037002	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.26894	-118.59768	PV1. INSTALL (42) SOLAR PANELS WITH MICROINVERTERS (IQ7-X-96-X-US). SYSTEM SIZE IS 13.86KWdc AND 12.76KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20115	13041-10000-13915	685 S NEW HAMPSHIRE AVE	90005	10	132B197   143	5094008004	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.06041	-118.29315	Plan check power and for new 7-story 177 unit apartment over 2 level of subterranean parking. Low rise building. 4000A service supplying building. Site located in methane buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20116	14041-10000-13203	406 N RAMPART BLVD	90026	13	138A205    49	5157004013	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1958.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.07396	-118.27377	PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.TRANSFORMERLESS INVEERTER AND WITH OPTIMIZER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20117	14041-10000-17977	4827 S CENTRAL AVE 1-118	90011	9	111A209   103	5108021026	C2-1VL	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Apartment			07/02/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	33.99948	-118.25668	Fire alarm system panel upgrade for existing 12-story, 122 occupancy apartment building. High rise. Number of fire alarm devices = 385.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20118	11041-20000-06900	21860 W BURBANK BLVD #190	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			Corrections Issued	04/07/2011 12:00:00 AM	ADDRESS	34.17198	-118.60379	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20119	16041-10001-02890	303 S VAN NESS AVE	90020	4	135B189   187	5504022026	R3-1XL	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.06874	-118.3153	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING 66 UNIT APARTMENT BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES IN THE COMMUNITY ROOM AND MANAGMENT UNIT. TOTAL AFFECTED AREA IS 20486 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20120	16041-20000-01553	7354 N WOODMAN AVE	91405	2	186B157   367	2328002094	R3-1	South Valley	Van Nuys - North Sherman Oaks			1271.03	Electrical	Electrical	Apartment			01/15/2016 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.20466	-118.43108	Plan check for power and energy for a new 4-story, 86-unit apartment building: 3 floors of residential over 1 floor of parking. Servize size is 1,600 amps. Fire alarm separation variance has been filed.Note: 2008 Title 24 Compliance Certificates being used; building submittal done on 12/30/2013. Building application has been generated under 13010-20000-04558.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20121	17041-20000-28129	2440 S BARRINGTON AVE	90064	11	123B153  1166	4260032058	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.03057	-118.44464	PV2.  Install 20 kW roof mounted grid tied PV system.  (65) modules with (2) Fronius Primo 10 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20122	13041-20000-05616	7001 W HOLLYWOOD BLVD	90028	13	147B181   114	5548003001	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.1017	-118.34196	New service and shell work for an existing building.  All work on plans is new.  Full Plan Check for Power and Energy.  All new tenants will require a full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20123	17041-20000-46521	23038 W LEONORA DR	91367	3	171B097   576	2042012050	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.16503	-118.62834	Plan check for solar pv system w/roof-mounted array on SFD.5.29kW ungrounded system. Using standard plan.(23) EnPhase IQ6-60 microinverters.(23) 295W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20124	13041-20000-26628	320 E SUNSET AVE	90291	11	109-5A143  83	4286007022	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.99526	-118.47456	CHANGE OF USE FROM OFFICE TO BAKERY AND RETAIL.   New 800 amp service, new loads, and lighting.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20125	13041-20000-05173	723 N MICHELTORENA ST PV-1	90026	13	141A203   134	5401007***	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.03	Electrical	Electrical	Apartment			02/28/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	09/10/2013 12:00:00 AM	ADDRESS	34.08142	-118.27983	Roof mounted photovoltaic system using Enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20126	10041-20004-13954	13488 W MAXELLA AVE	90292	11	105B153    78	4212004012	[T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Apartment			04/12/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	Changes from previously approved plans.  Changes include conduit routing underground for dewatering and future crane equipment.  Plan check for power only.*****Plan check temp power service and equipment in methane zone*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20127	18041-20000-48158	8440 N BALBOA BLVD 104	91406	12	192B133   538	2689019016		North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.22397	-118.50243	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20128	14041-10000-34897	3708 N EAGLE ROCK BLVD	90065	1	154-5A217 154	5457029020	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM			PC Info Complete	04/21/2015 12:00:00 AM	ADDRESS	34.11757	-118.23347	NEW600A  SERVICE FOR COMMERCIAL BUILDING; NEW FEEDERS TO EXISTING PANELBOARDS AND WIRE GUTTER; ALL LOADS ARE EXISTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20129	15041-10000-02843	21215 W BURBANK BLVD	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.17353	-118.59268	Title 24 plan check only.  Total area = 13,407 sq. ft.T.I. to 6th floor of existing office building.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20130	14041-10000-00473	1732 N VERMONT AVE	90027	4	147B197   146	5590026001	[Q]C4-2D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM			PC Approved	01/09/2014 12:00:00 AM	ADDRESS	34.10257	-118.29159	Studio office TI.  3,050 sq ft.  Title 24 plan check for changes to lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20131	16041-10001-44270	1600 S GAFFEY ST	90731	15	012B197   427	7454034031	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	33.72959	-118.29219	pc for changes to approved set of plans due to new roof layout. no other changes,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20132	17041-20000-28530	3840 S GRAND VIEW BLVD	90066	11	111B157   101	4235025031	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.00376	-118.43016	new fire alarm system 38 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20133	14041-20000-03091	4840 N CLEON AVE	91601	2	168B173   311	2421013002	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			02/04/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM				PC FOR 9 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED. 3 STORIES OR MORE. PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20134	14041-20000-16189	444 S FLOWER ST 48th floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for energy only.~54 story high rise building, renovation of bathroom on 48th floor. New lighting (incl. emergency).Permit under separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20135	16041-10000-37045	7245 W VALMONT ST	91042	7	204B197  1051	2565013031	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.25241	-118.29016	PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 23350 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20136	19041-20000-02745	3868 S REDONDO BLVD	90008	10	117B177   278	5029004012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.01636	-118.35927	Plan check for PV roof mounted system with Energy Storage System, system size: 14.4KW with 40 PV Modules and 1 inverter(11.4KW), LG Chem 9.8kWh.Fees $16.19 due to Caifornia Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20137	18041-20000-26134	1800 N WINONA BLVD	90027	13	150A195   249	5544012044	R3-1	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Issued	05/21/2019 12:00:00 AM	ADDRESS	34.10377	-118.30182	Plan check for a PV2 roof-mounted PV system. System size is 71.76 kWdc/63.61 kWac-CEC and consists of (5) 12 kWac rated inverters, (1) load center, and (208) modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20138	16041-10000-09013	2054 S MIDVALE AVE	90025	5	126B153   111	4323003012	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.04493	-118.43386	PV1, rooftop solart installation 6kW    (22) SE-F270     (1)SE6000A-US   P300 being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20139	17041-20000-40407	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.23911	-118.3725	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR WAREHOUSE LIGHTING. 51,577 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20140	19041-20000-35100	11835 W OLYMPIC BLVD Ste. 860E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.03301	-118.45119	Plan check for Title 24 energy only existing office Tenant Improvement new lighting and existing circuits. Total area: 3376 sq ft,.B#19016-40000-26703	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20141	12041-20000-08708	8460 N SAN FERNANDO ROAD	91352	6	192B173   259	2632027030	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			Reviewed by Supervisor	06/05/2012 12:00:00 AM	ADDRESS	34.22387	-118.37501	"1200A switchgear relocation. Consolidate 4 (single phase 120/208, 3phase 240, 3phase 480, ....) different services into one service (480 3 phase). Plan check for power.""COMPLY WITH DEPARTMENT ORDER effective date12/26/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20142	12041-10001-01725	919 S ALBANY ST	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	ADDRESS	34.04913	-118.27045	Plan check for T24 Energy mandatory measures and emergency lighting. Office space TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20143	17041-10001-15238	727 E 22ND ST	90011	9	121-5A209 358	5131012024	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.0248	-118.25869	Plan check for a lost PV plan.(((Rooftop solar installation on SFD, system is 2.64kW DC)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20144	19041-20000-41056	11881 W TERRA VISTA WAY #110	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/12/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20145	13041-10002-06866	4709 N LOWELL AVE	91042	7	201B205   734	2571005030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	PIN	34.24406234	-118.26662577	Change of wire from THWN-2 to USE-2 past first DC disconnect on PV source circuit.  Plan check for modification of approved set per inspector request.Original Work Description: PV1 FOR 1 STORY SINGLE FAMILY DWELLING. 14 PANELS AND 1 INVERTER. TRANSFORMERLESS WITH OPTIMIZER. SOLAR MODULES LOCATED ON SEPERATE STRUCTURE. NOT A METHANE ZONE. [INVERTER: SOLAR EDGE SE3000A-US] [SOLAR MODULE: TRINASOLAR TSM-240 PC/PA05].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20146	16041-10001-20233	450 S WESTERN AVE # 207	90020	10	135B193   649	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	PC FOR FIRST TIME OCCUPANCY. 24 ALREADY APPROVED AND PERMIT ALREADY ISSUED. THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20147	16041-30001-21204	2180 S WESTWOOD BLVD 2F, 2G, 2H	90025	5	126B157   253	4321012071	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.04421	-118.4318	12/06/2016 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the floor plan layout. All changes have been reflected onto the Title 24 Compliance forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,340 sq. ft.Note: Building application has been generated under 16016-30000-08345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20148	13041-10001-24089	2920-2930 W ROWENA AVE BUILDING 1	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.10823	-118.26884	CHANGES MADE TO PREVIOUSLY APPROVED SET:A) ADDITION OF PV TO EACH RESIDENTIAL UNIT B) REMOVE LIGHT FROM GARAGE C) ADDITIONAL J-BOXES IN RESIDENTIAL UNITS FOR FANS, LIGHTS, ETC.D) REMOVE LIGHT (FL) AND REPLACE WITH INCANDESCENT WITH DIMMER IN HALLWAYS (((NEW BUILDING. APARTMENT.  1 OF 6 TOTAL UNITS. BUILDING 1. NEW 400 AMP SERVICE.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20149	10041-20000-08243	11911 W SAN VICENTE BLVD #345	90049	11	129B145    78	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	34.05295	-118.47002	TENANT IMPROVEMENT IN OFFICE AREA. THIS P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20150	12041-10000-25457	3447 S GRAND AVE	90007	9	118-5A203  49	5122021011	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.01939	-118.27686	Plan check AND permit for title-24 part 6 energy only. 6th floor of parking structure. Full plan check subject to field verification.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20151	19041-20001-34468	10989 W BLUFFSIDE DR PV1	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.14187	-118.36957	PV2 BUILDING #3 (N) 20.4 KW AC/22.68 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (63) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20152	18041-20000-40141	340 N MADISON AVE	90004	13	138B197   141	5501002033	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.07748	-118.28901	Plan check for Title 24 only in existing space Office T.I. Total area: 17650 sq ft. B#18016-10000-27843	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20153	10041-10001-24650	440 S VERMONT AVE #106 & 107	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Modification to previously approved set of plans for 1st time tenant in spaces 106 and 107 combined into one space.  See existing permit # 10041-10000-24650.  Change in lighting and additional circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20154	14041-10001-35218	3418 N PUEBLO AVE	90032	14	142-5A235 122	5218016025	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	PIN	34.08543054	-118.17390482	Changes to an approved set. Note changes under delta 1. (((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4KW. (16) HUYINDIAY MODULES(16) ENPHASE MICROINVERTERS))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20155	17041-20001-15765	16745 W SATICOY ST	91406	6	186B133   144	2205008031	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.20857	-118.49825	6.12.2017 - Plan check for energy only. New lighting for fermentation room (for tea). 2,242sqft.Permit pulled under master application number.========REINSTALL EXITING LIGHT FIXTURES AND ADD NEW SWITCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20156	13041-10000-14437	919 S TOWNE AVE	90021	14	124-5A211 173	5132002003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.03527	-118.249	Retail TI.  New 600A service and distribution system.  Energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20157	17041-30001-12462	6600 N TOPANGA CANYON BLVD 99a	91303	3	180B101   822	2139004044	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	05/16/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	05-26-2017 Changes to an approved set of plans. Changes include addtional and relocate lighting fixtures. Changes has been clouded as delta 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20158	16041-20000-03854	11449 N SPROULE AVE	91331	7	213B161   799	2532006006	(Q)RD6-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.2782	-118.40659	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (25) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20159	18041-20000-44326	5926 W BARTON AVE	90038	13	144B189  1078	5534027038	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.0876	-118.32305	PV2.  Install 2.48 kW roof mounted grid tied PV system. (8) modules with microinverters.  AC combiner panel with monitoring circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20160	12041-20000-10813	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	Tenant improvement for Equinox Gym. Plan check for power and energy. Building is equipped with a generator. Commercial high-rise. 31,700 conditioned sqft. Fire alarm variance will be FILED IN THE FUTURE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20161	16041-10000-44871	1999 S AVENUE OF THE STARS 38th FL.	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Issued	01/12/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI TO OFFICE SPACE. NEW LIGHTING AND BUILD OUT. PC FOR ENERGY ONLY. T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20162	19041-20000-42719	9640 N OWENSMOUTH AVE	91311	12	201B105   205	2746015006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.24548	-118.60221	INSTALL (3) NEW PANELS, EQUIPMENTS AND (1) 150 KVA TRANSFORMER ON EXISTING 2500 AMP SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20163	17041-10000-33190	2001 E 103RD ST	90002	15	091-5A215 121	6046021001	A1(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	05/30/2020 12:00:00 AM	ADDRESS	33.94325	-118.23651	Plan check for power and energy of new Community Education Center, Barn, Mastergardener Center. Total area: 44,220. Application 1 of 3 This permit covers the main switchboard and panels CAC, GL, GP and EV panels.Note: 3 Buildings supply by 1 Service(800A). There are 3 electrical application with 1 plan. Building application number: 17010-10000-02862	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20164	17041-20000-31254	3616 S TROUSDALE PKWY Ste 107 &-108	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.01983	-118.28534	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,349 sq. ft.Note: Building application has been generated under 17016-10000-25022	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20165	15041-20000-43192	2222 W ELSINORE ST	90026	13	141A207   364	5402031011	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1956.00	Electrical	Electrical	Apartment			12/22/2015 12:00:00 AM			Reviewed by Supervisor	02/12/2016 12:00:00 AM	ADDRESS	34.07919	-118.26584	Plan check for power and energy. Project site is a new 4-story apartment building: 3 levels of residential over 1 level of parking garage. Total indoor lighting area = 10,185 sq. ft. and total outdoor lighting area = 818 sq. ft.Note: Plan check is for (2) building, both of which have been included in (1) set of plans. Both building area being fed from (1) LADWP service. Other building can be found under application 15041-20000-36484.FIRE ALARM VARIANCE NOT YET FILEDNote: Building application has been generated under 15010-30000-03156	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20166	18041-10000-26944	12842 W PIERCE ST	91331	7	207B161    22	2536016009	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.2673	-118.413	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20167	14041-10000-09865	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.2426	-118.55846	T.I. of existing Starbucks.  New fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20168	13041-10000-28669	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.04594	-118.25757	1000A temporary power service and distribution equipment.consists of new temp power, xformers, man lifts , ndpe. and spider boxes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20169	10041-20000-25614	2010 S CENTRAL AVE	90011	9	120A211   262	5119001004	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Southeast / Central Avenue		2270.10	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Expired	12/09/2015 12:00:00 AM	ADDRESS	34.02304	-118.25161	PLAN CHECK POWER AND ENERGY FOR NEW RETAIL (FIRST TIME TENANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20170	18041-20001-15027	20212 W ARCHWOOD ST	91306	3	180B113   164	2134016008	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM			PC Approved	07/09/2018 12:00:00 AM	ADDRESS	34.19245	-118.57396	Revisions to approved set.  Addition of ATS to system design for transfer of power from utility to ESS for back-up panel.  (((PV1.  Install 4.95 kW DC roof mounted grid tied PV system.  (15) modules with 7.6 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20171	17041-30000-00423	4504 N COLBATH AVE	91423	4	168B153   828	2271004046	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.1533	-118.43644	Installation of fire alarm system in new 12 unit apartment.  Total system size = 53 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20172	16041-30000-02200	601 S FIGUEROA ST 1800	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	Title 24 plan check only.  Total area = 6,615 sq. ft.   T.I. to existing commercial highrise office space.  New 225 A UPS panel + lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20173	12041-10002-02213	7508 W MELROSE AVE	90036	5	141B177   659	5526017027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Info Complete	02/05/2013 12:00:00 AM	PIN	34.08337436	-118.35354775	changes to approved set of plans 12041-10001-02213+revised lighting circuit designation+relocated house panel HP from level above , shifted security panel and fire sprinkler control panel, revised telephone mounting board.+revised total load SES summary and panel schedule C and HPPlan check power and energy for new Fresh & Easy market with new 2000A service. Existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20174	14041-10000-24986	11220 W MOORPARK ST	91602	2	165B173   353	2366008002	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Expired	04/12/2017 12:00:00 AM	ADDRESS	34.15023	-118.3753	PV2, INSTALL 32130 W DC ROOF-MOUNTED SOLAR ARRAY ON A APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222(126) MODULES: CANADIAN SOLAR CS6P-255P(4) INVERTER: SMA AMERICA SB7000US-12	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20175	10041-10000-24460	1408 W WASHINGTON BLVD	90007	1	126A201   178	5056026040	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2217.10	Electrical	Electrical	Apartment			12/08/2010 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.0398	-118.28697	NEW 42 UNIT APARTMENT BUIDING.  VARIANCE FORM WAS SUBMITTED FOR THE FIRE LIFE SAFETY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20176	13041-10000-36309	1851 W SAN FERNANDO ROAD	90065	1	148-5A215 107	5442004011	[Q]MR1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.10033	-118.23528	PLANCHECK FOR T24 ENERGY ONLY. < 400 AMPS.  APPROX 2000 SQFT. TI AND  REMODEL OF EXISTING CATERING  RESTAURANT.   NO SEATING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20177	15041-20000-16017	651 W USC MC CARTHY WAY UNIT 3BYZ	90089	9	120A201    78	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.02135	-118.28288	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CLASSROOMS IN USC THOMAS & DOROTHY LEAVEY LIBRARY. ROOMS 3BYZ. 1439 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20178	12041-20001-22468	20740 W MARILLA ST	91311	12	201B109   177	2748004045	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Expired	02/25/2015 12:00:00 AM	ADDRESS	34.24795	-118.5856	Changes to approved set of plans. Plan check for energy and emergency lighting. Alteration to room layout. Relocate machinery, additional lights (with emergency lighting)  & AC in an existing industrial building.  Not in a classified/hazardous location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20179	13041-20000-02989	333 S HOPE ST BASEMENT	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Approved	02/05/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	ENERGY PLAN CHECK ALSTON & bIRD LLP.  BASEMENT LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20180	13041-10000-12362	1721 N DELOZ AVE	90027	4	148-5A203 211	5430006034	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.10134	-118.27747	PV1 ROOF MOUNTED SOLAR INSTALLATION IN A SFD. SYSTEM SIZE IS 4.655 KW USING POWER OPTIMIZERS. 1 STRING OF 19 MODULES AND A SINGLE INVERTER. [INVERTER: SOLAREDGE # SE5000A-US |||| MODULES: TRINA SOLAR # TSM-245PC05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20181	19041-30001-40817	211 S CENTRAL AVE UNIT#211-213	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Issued	10/22/2019 12:00:00 AM	ADDRESS	34.04741	-118.23966	PLAN CHECK FOR ENERGY ONLY. CHANGES TO AN APPROVED SET OF PLANS TO MATCH FIELD CONDITIONS AND UPDATE ELECTRICAL DESIGN. NOTE CHANGES ON CLOUDED AREAS. Tenant improvement to retail space, new lighting and associated load. Total area: 2311 sq ftB#19016-30001-19728	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20182	13041-10000-00089	746 S CENTRAL AVE	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			01/02/2013 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.03537	-118.24198	"LIGHTING FOR STAIRWAY T242 STORY PRODUCE MARKET T24""COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20183	11041-10000-25875	10720 W PALMS BLVD	90034	11	120B161   828	4252036044	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.02	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	03/07/2012 12:00:00 AM	ADDRESS	34.02421	-118.4121	Remove and replace non-working fire alarm panel and annunciator with like, compatible, model.  Building is an existing 16-unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20184	19041-20000-31291	14747 W ORACLE PL	90272	11	132B129    36	4422033004	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.05569	-118.52046	INSTALL (2) NEW TESLA POWERWALL BATTERIES ON EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20185	18041-10000-41266	6040 N CARPENTER AVE	91606	2	177B169   671	2334016040	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.18068	-118.39092	PV1. NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 2.4 KWdc/2.24 KWac. PV SYSTEM IS CONNECTING TO THE POINT OF INTERCONNECTION OF A SINGLE FAMILY  HOME. (8) MODULES-SOLARWORLD SW 300 AND (8)MICROINVERTERS-ENPHASE S280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20186	16041-10002-09208	3500 W WILSHIRE BLVD	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/17/2017 12:00:00 AM	ADDRESS	34.06157	-118.30077	11/14/17 PC FOR REVISIONS TO APPROVED SET TO REFLECT FIELD INSTALLATION.  CHANGES MARKED UNDER DELTA 12. SCOPE INCLUDES REMOVAL OF SIGN AND EXTERIOR LIGHTS WITH REVISION TO PANEL SCHEDULE AND TITLE 24 FORMS. ALL PERMIT FEES PAID UNDER ORIGINAL PERMIT. THIS IS PLAN CHECK ONLY!THESE CHANGES,  TOGTHER WITH DELTA 13 (10003) WERE TO BREAK THE ORIGINAL WORK (UNDER ORIGINAL) TO EXTERIOR AND SIGN LIGHTS TO 2 PHASES DUE TO FINANCIAL HARDSHIP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20187	15041-20001-13625	4269 N BECK AVE	91604	2	165B169   688	2365026022	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	34.14694	-118.38348	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.2 kWac and consists of (2) inverters, (45) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20188	14041-20000-10518	4935 N MEDINA DR	91364	3	168B105   423	2171013068	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.15786	-118.60168	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. 2.8 KW DC.(12) ENPHASE M215(12) LIGHTWAY LW 235	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20189	18041-10000-00572	2602 N NORTH BROADWAY	90031	1	138A221    90	5204011006	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.07348	-118.21538	PC for T24 only for change of use from retail to bakery. Installing new 400A service with new panels, lights, receptacles and equipment. Total area is 2917sqft. B#17016-10000-37001	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20190	13041-20000-22228	2987 N INGLEDALE TER	90039	13	154-5A207 375	5435030052	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.11633	-118.26569	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW USING 18 MODULES WITH POWER OPTIMIZERS. TRANSFORMERLESS SYSTEM. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20191	19041-30000-32580	10690 W SOMMA WAY	90077	5	144B149   205	4370005038	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM			PC Approved	03/12/2020 12:00:00 AM	ADDRESS	34.09037	-118.45033	New 1200A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power only - electrical permit will be issued under building combination permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20192	17041-10000-27248	1120 W WASHINGTON BLVD	90015	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	PIN	34.03794253	-118.28208997	PLAN CHECK FIRE ALARM SYSTEM FOR NEW 4 STORY MEDICAL OFFICE BUILDING. PROJECT CONSIST OF 1 FIRE ALARM PANEL AND 221 DEVICESBuilding application number: 16010-10000-03992	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20193	19041-20000-52962	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			Reviewed by Supervisor	02/27/2020 12:00:00 AM	ADDRESS	34.09786	-118.29745	ADD NEW PANELS, LIGHTS AND EQUIPMENTS ON EXISTING 4000 AMP SERVICE.NOTE:MEDICAL FACILITY AS INDICATED IN BUILDING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20194	17041-10000-21854	126 N KINGS ROAD	90048	5	138B173   521	5511010007	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			07/11/2017 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	10/05/2020 12:00:00 AM	ADDRESS	34.07529	-118.37199	Full plan check for a 8-unit 4-story apartment building with a basement garage. PC for new 600A 120/240 V service. Building is located in Methane Zone. Building#17010-10000-00489	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20195	09041-10003-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans for the north  and south concourses at TBIT -GDN 062	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20196	12041-20000-08939	14150 W VAN NUYS BLVD #105	91331	6	201B153    32	2645021001	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	34.25162	-118.4416	TI to approved core and shell. Dental office. Plan check for power and energy. 2640 conditioned sqft. Single story with mezzanine.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20197	17041-10001-32642	6148 E MOUNT ANGELUS DR	90042	1	153A229   151	5484033026	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.1143	-118.18813	PC for changes to approved set. Relocating two modules, inverter and PV disconnect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20198	18041-10000-29154	845 N ALAMEDA ST	90012	14	132A215     9	5408011908	PF-1VL	Central	Central City	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.05795	-118.23735	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20199	19041-20000-14952	6320 N CANOGA AVE ste 900	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.18499	-118.59722	ti to an existing commercial building(high rise) adding new lighting new controls to existing panels.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20200	19041-10000-12816	4501 S SLAUSON AVE	90230	11	111B161   957	4218001017	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Issued	05/08/2019 12:00:00 AM	ADDRESS	33.99746	-118.41339	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDE NEW OUTDOOR LIGHTS FOR CVS PHAMACY. TOTAL AFFECTED AREA IS 19979 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20201	12041-20000-01947	601 S FIGUEROA ST #2700	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Approved	01/26/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	energy plan check suite 2700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20202	16041-10000-33244	4000 N EAGLE ROCK BLVD	90065	1	156A217   245	5472001057	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.11994	-118.22853	TITLE 24 FOR EXISTING LOW RISE BUILDING. CHANGE OF USE FROM RETAIL TO VETERINARY CLINIC. TOTAL SQ. FT. 1839	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20203	18041-20000-31638	1052 N SWARTHMORE AVE #2-104	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.04801	-118.52484	first time tenant.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20204	12041-20000-30057	3377 W OLYMPIC BLVD	90019	10	129B193   285	5081033011	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.0528	-118.31175	Plan check for fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20205	12041-10000-18974	11003 N CHIMINEAS AVE	91326	12	210B125   565	2715015012	RE11-1	North Valley	Northridge	Northridge East		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.26998	-118.52876	Plan check for new 6.5KW roof mounted photovoltaic system. Single family dwelling. Permit to include main service panel upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20206	16041-10000-29194	4601 S BROADWAY	90037	9	112-5A203 274	5110009001	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.00182	-118.27861	plan check for TI-24 in existing space office TI on 1st floor of 2 story building total lighting area 9772 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20207	10041-10000-03624	6724 W HOLLYWOOD BLVD	90028	13	148-5A185 146	5547012018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	06/28/2011 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.10139	-118.33715	T.I. for 8-story high rise building Church of Scientology.  Plan check for power and energy. New electrical system with 1600A service. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20208	15041-20001-14559	12751 W MILLENNIUM Building A	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	10/23/2015 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes include the installation of (1) new panel and the relocation of lighting circuits to the new panel.*****Previous Work Description*****Title 24. Plan check for energy for energy only. Existing retail building. Adding new lighting including emergency. Total sqft. 2,646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20209	17041-10000-35336	515 S FIGUEROA ST 1st FL	90071	14	130-5A209  85	5151021011	C2-4D, RD1.5-1	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	PC for T24. Installing three new panels, 75kVA XFRM, new lignts, new receptacles and equipment. B 17014-10000-04813. Total area is 7820sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20210	14041-10000-30539	837 E 4TH PL	90013	14	127-5A215 207	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.04401	-118.23553	Plan check for power and energy.  New 134,180 sq. ft. above ground 8 story parking structure.  Re-check list of equipment.Fire Alarm variance issued 11/04/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20211	14041-20001-09846	17928 W TIARA ST	91316	5	177B129   621	2159012006	R1-1	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.1789	-118.524	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. NON STANDARD PLAN. SYSTEM SIZE: 7.5KW.(30) CANADIAN SOLAR CS6P 250(1) SOLAR EDGE SE6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20212	14041-10001-14918	2239 W QUEENSBOROUGH LANE	90049	5	150B141    86	4377046004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.10938	-118.47778	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 7.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20213	17041-10000-16092	1541 S CENTRAL AVE	90021	14	121-5A211 271	5132023027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.02676	-118.24871	PC FOR T24 ONLY. (N)one story, accessory storage/office building. TOTAL AREA 635 SQ FT. POWER PLAN CHECK IS UNDER 16041-20000-36145, B # 15010-10000-03187	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20214	11041-10006-14514	7149 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	PIN	33.94386821	-118.41794839	((((((((((((((((((     12/21/12 Modification made to previously approved set of plans under permit #10005.  A 100A panel was added plus 2 exhaust fan on generator. )))))))))))))))))))))))   (((((((((((((((((((((((( Changes made to previously approved set, two pull section added .   08-14-12  ))))))))))))))))))  NEW FIRE WATER DELUGE PUMP BUILDING AT LAX.  FULL PLAN CHECK.((((((( changes made to previously approved set, remove exhust fans from emergency board feedinf fire pumps and remove neutral from the wiring system. 3-2-12))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20215	10041-20002-19618	15524 W LANARK ST	91406	6	189B145    64	2654040004	M2-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	34.21839	-118.47093	2nd supplemental to previously approved plans.  Changes include adding news branch circuits and main C/B rating.  No changes in lighting.  Plan check for power only.*****Supplemental to previous submitted plans under Title 24 EPC only.  T.I. from industrial space to place of assembly (Banquet Hall).  A full EPC is required.  Install new panels and lighting.  Plan check for energy and power. *****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20216	11041-20000-23549	11111 W SANTA MONICA BLVD Ste 620	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM			PC Approved	11/03/2011 12:00:00 AM	ADDRESS	34.04771	-118.44481	T.I.  Remodel of light fixtures in an existing office space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20217	19041-10000-29920	18439 W VENTURA BLVD	91356	3	171B125    19	2160008031	C2-1, C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.16838	-118.53457	Design build. TI OF EXISTING DELI/BAKERY DEPT. OF VONS STORE. INSTALLING NEW CIRCUITS AND LIGHTS. EMERGENCY LIGHTS ARE EXISTING TO REMAIN. TOTAL AREA 26,501 SQR FT. BULDING PERMIT: 19016-10000-23890	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20218	12041-10000-23591	4292 S CAMPBELL DR	90066	11	108B157   126	4232014015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	33.99542	-118.42465	FOR A SFD,ROOF-MOUNTED 3.43KW  PHOTOVOLTAIC SYSTEM USING MICRO INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20219	19041-20000-41038	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20220	19041-30000-07347	700 S FLOWER ST 20th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is the 20th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 18,808 sq. ft.Note: Building application has been generated under 18016-10000-30559	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20221	18041-10000-32382	4018 S BUCKINGHAM ROAD	90008	10	117B181  1088	5032004909	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			08/24/2018 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	02/01/2021 12:00:00 AM	ADDRESS	34.0139	-118.34221	Full PC for Power and Energy for NEW 4-STORY 103-UNIT AFFORDABLE(100%) HOUSING PROJECT. Total Affected area is 79740 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20222	18041-10000-15851	933 E VERNON AVE	90011	9	112-5A209  33	5115013025	C2-1VL	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Apartment			04/30/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.00407	-118.25923	FULL PC FOR POWER AND ENERGY FOR A NEW 4 STORY 21 UNIT APARTMENT BUILDING. SCOPE INCLUDES NEW SERVICE RATED AT 800A NEW PANELS (ONE TYPICAL PANEL FOR 21 UNITS), NEW LIGHTS, AND NEW CIRCUITS. TOTAL AFFECTED 5566 SQ. FT. B#16010-10000-02825 NOTE: 7 TYPICAL UNITS / 100% AFFORDABLE HOUSING (25% FASTER TO ASIGN)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20223	18041-10001-06406	1323 S ORANGE GROVE AVE 1-61	90019	10	129B177   318	5086004004	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			05/03/2019 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	34.05256	-118.36538	"DELTA ""3"" CHANGES TO APPROVED. REDUCING 4 CONDUITS TO 2 CONDUITS WITH THE SAME SIZE AL FESDERS. <<<Plan check for power and energy for 5-Story 61-Unit Condominium. Scope includes a new 4000A 120/208 V 3 Phase 4 Wire service, new panels, and new lights. Total area: 68,110 sq ft. B#16010-10000-05142>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20224	10041-10000-19269	400 W WORLD WAY TERM 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	12/07/2010 12:00:00 AM	PIN	33.94094587	-118.40577128	REPLACEMENT OF 14 ESCALATORS,3 ELEVATORS, AND 2 MOVING WALKS AT LAWA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20225	13041-10000-31933	1246 N ROSCOMARE ROAD	90077	5	144B145   102	4377021005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.09242	-118.46246	$0 permit fee is due to the 2012 Senate Bill No. 1222.{{Pv1, installing 31 kw DC roof-mounted solar array,  micro inverter: M215 Enphase . 123 module: LG280.}}	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20226	16041-10001-27488	8500 W BEVERLY BLVD #613	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	"CHANGES TO APPROVED SET PER INSPECTION. CHANGES INCLUD NEW LIGHTING FIXTURES  TO AND REVISION TO TI-24  FORM TO REFELECT THE CHANGES.  Plan check for T-24 only.  TI  at an (E) retail  space ""Steve Madden"".  Newly connected load < 400A.  Total affected area: 1,930 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20227	12041-10000-07107	3253 W SHASTA CIR NORTH	90065	14	159A215    98	5678026004	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	ADDRESS	34.13046	-118.23449	NEW ROOF MOUNTED 5.76 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20228	16041-20000-08321	4415 W DUNDEE DR	90027	4	154-5A201 171	5588033016	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM			Reviewed by Supervisor	03/15/2016 12:00:00 AM	ADDRESS	34.11631	-118.28661	PV.  Installation of 4.59 kW system with ground- and roof-mounted portions.  Service upgrade included.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20229	12041-10001-18072	630 W HARRY BRIDGES BLVD MAIN GATE	90744	15	027B205   442	7440006***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	33.77068	-118.26868	((8/19/2014 - Supp. app. for changes made to an approved set to reflect field changes at request of inspector.  Addition of a series rated circuit breaker.  Changes are marked with delta 13))MASTER PERMIT SCOPE OF WORK: Main Gate and Main Enterance.  Plan check power  for new 400A switchboard, Main Entrance, high mast poles. Location in Methane Zone . Rear Berth 136-139.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20230	12041-20000-00124	6908 N COMANCHE AVE	91306	3	183B113   650	2135031019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.196	-118.57196	Enphase inverter PV system on roof of single family dwelling.  A variance to install Enphase M215 inverters was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20231	11041-10000-16978	4221 W BEVERLY BLVD 7-11 Store	90004	13	138B193   459	5520026018	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20, 1926.20	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	10/21/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.07645	-118.30093	NEW 7-ELEVEN STORE.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20232	14041-10000-14659	1525 N GOWER ST	90028	13	148-5A189 301	5546026029	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.09849	-118.32256	Installing a new fire alarm system into the Parking and Bungalow buildins for the redevelopment in an existing low-rise building.  Fire alarm only system size = 383 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20233	15041-10000-15677	11821 N MCLENNAN AVE	91344	12	216B133   635	2610002028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.28467	-118.50113	PV1, INSTALL 10.46 KW DC ROOF-MOUNTED SOLAR ARRAY  ON A SINGLE FAMILY HOME. (32) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTERS: POWER ONE PV1-3.8-OUTD-US AND 6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20234	12041-20000-03595	517 S WILTON PL	90020		135B189   696	5504019020	R3-1		Wilshire	Greater Wilshire			Electrical	Electrical	Apartment			02/16/2012 12:00:00 AM			Corrections Issued	02/16/2012 12:00:00 AM	ADDRESS	34.06469	-118.31433	Install new light fixtures in 10-car  parking garage, and install outdoor lighting of the new 5 units apartment.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20235	13041-10001-35535	6577 S 4TH AVE	90043	8	102B189   164	4008005007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	33.97923	-118.32174	Expedited RSES plan check per applicant request.{{PV1, Install 3.75 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (15) modules: Yingli YL250p-29b.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20236	12041-10000-26025	12746 W JEFFERSON BLVD 1-4	90094	11	102B161  1167	4211033012		West Los Angeles				2756.01	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Closed	12/01/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check for new methane gas detection system. Building 1, 2, 3, and 4 with common subterranean parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20237	17041-20002-40019	9210 N SHOSHONE AVE	91325	12	198B129   313	2766010014	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.23817	-118.51766	01/18/2018 Changes to an approved set of plans. Changes have been made to install provisions for the future installation of a battery storage system.*****Previous Work Description*****PV1.  Install 12.9 kW roof mounted grid tied PV system.  (36) AC modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20238	17041-10000-05696	8542 N VENTURA CANYON AVE	91402	6	192B157   182	2637005017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.2256	-118.43173	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(18)AXITEC AXIPOWER AC-265/156-60S(1)INVERTER-FRONIUS PRIMO 5.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20239	11041-20000-27690	4436 N WINNETKA AVE	91364	3	165B113    52	2174026006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2011 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.15172	-118.57142	New 8.28 KW roof mounted PV system for single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20240	18041-20000-21021	10961 N GOTHIC AVE	91344	12	210B137   704	2680022028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.26988	-118.48923	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM RATED 7.6KVA, CONSISTING OF 26 MODULES WITH P400 POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20241	10041-20000-25356	5767 W CENTURY BLVD #GF14-GF18	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	33.94572	-118.38294	Plan check T24 energy (general/emergency) lighting for TI on ground floor GF-14-GF18	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20242	16041-10000-32896	903 W OLYMPIC BLVD	90015	14	129A207   293	5138005036	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.04577	-118.26611	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RESTAURANT TO RETAIL SPACE. TOTAL AFFECTED AREA IS 5519 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20243	18041-10000-45655	9930 W NATIONAL BLVD	90034	5	123B165  1108	4311005013	C2-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.03036	-118.4022	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20244	17041-20000-29445	3709 S TROUSDALE PKWY STE 105	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.01851	-118.28672	ti to an existing commercial building.  adding new lighting new controls to new panel.  newly connected load < 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20245	19041-20000-38591	1361 S KELTON AVE 1-15	90024	5	132B153   869	4324007017	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			09/25/2019 12:00:00 AM	06/28/2022 12:00:00 AM		Issued	06/28/2022 12:00:00 AM	ADDRESS	34.05517	-118.4445	Plan check for power and energy 800A new service. Scope of work includes panels, equipments and lights. Total area: 35,853 sq ft. B#17010-30000-03693	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20246	13041-10000-34144	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.06188	-118.30486	Construction of a mixed-use structure with one basement parking level, three parking levels at or above grade, and a level 4 play deck and central plant, associated site work and new play yards for adjacent buildings not a part of this permit application.  Plan check for power and energy, 181,543 sq ft.  New 1600 A distribution board, 45 kVA XFMR and associated distribution equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20247	12041-10000-12873	19214 W MAYALL ST	91324	12	204B117   448	2729025023	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	06/20/2012 12:00:00 AM	ADDRESS	34.25391	-118.55177	PV system for single family dwelling. 9.156KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20248	16041-10000-44594	1100 N VERMONT AVE	90029	13	144B197   700	5542029038	C2-1D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM			Reviewed by Supervisor	12/28/2016 12:00:00 AM	ADDRESS	34.09119	-118.29154	FULL PC FOR POWER AND ENERGY FOR A NEW ONE STORY RESTAURANT BUILDING(CORE & SHELL). SCOPE INCLUDES A NEW 1200A 480/277V 3PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW TRANSFORMERS, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 7000 SQ. FT. B#16010-10000-04811	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20249	10041-10001-00563	17380 W SUNSET BLVD	90272	11	126B117   650	4415019012	C2-1VL, C2-1XL, P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			PC Info Complete	04/01/2011 12:00:00 AM	ADDRESS	34.03924	-118.55462	Relocate the rooms at the back of the building between rows A and B.  Relocated panels NX, NB, and EMS.  Added 3 circuits to panels NB, NA, and 5 circuits to panel NC.  Modified T24 lighting forms.  No major changes in load or T24 installed lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20250	15041-10000-20034	16000 W VENTURA BLVD STE 600	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.15584	-118.48164	PC FOR ENERGY. T.I. FOR OFFICE . NO CHANGE OF USE. HIGH RISE BUILDING. TOTAL AREA 9910 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20251	15041-10000-02084	11526 W BURBANK BLVD	91601	2	174B169   866	2350004039	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.17199	-118.3832	Installation of new roof mounted solar PV array on existing commercial property.  Total system size = 16 kWac.  2 inverters with 68 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20252	13041-10000-13309	1200 S CLUB VIEW DR unit 800	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			05/22/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.06748	-118.42481	PLAN CHECK FOR T24 ENERGY ONLY FOR COMMON AREAS. 173.6 SQFT, EMERGENCY LIGHTING. Alteration to 8th story unit and adjacent common area in existing highrise condominium building.  Buildout electrical systems to tenant space for new luxury residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20253	16041-30002-35988	7131 W MANCHESTER AVE	90045	11	096B161   664	4113013027	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	33.95996	-118.41793	"12/13/2016 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,160 sq. ft.Note: Building permit has been pulled under 16016-40000-24557*****Previous Work Description*****SUPPLEMENTAL PERMIT FOR PERMIT #16041-40000-35988 TO PAY FOR CODE ENFORCEMENT FEE PER INSPECTORS REQUEST.ADD 15 BRANCH OUTLET AND  ADD 28 LIGHT FIXTURES. ""COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 10/12/16. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20254	13041-10000-22517	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	PIN	33.93847109	-118.41935625	-Approved per F.Y(REPLACING WEST  ENDS OF RWY7L AND EXTENDIND RWY 7L  & ASSOCIATED TWY AT LAWA. WORK INCLUDES THE REMOVAL AND REINSTALLATION OF RWY & TWY LIGHTING SYSTEMS; NEW AIRCRAFT-RATED PULLBOX AND MANHOLES; NEW DUCTBANKS/CONDUITS;)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20255	15041-20000-42251	359 S LA BREA AVE	90036	4	135B181   359	5508001031	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.06719	-118.34433	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (STARBUCKS). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 2605 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20256	19041-10000-02296	445 S FIGUEROA ST FLOOR 18	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	T-24 ONLY FOR A RESTROOM TI ON THE 18TH FLOOR. SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECETED AREA IS 650 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20257	18041-10001-27227	1609 S BARRINGTON AVE	90025	11	126B149   508	4262012025	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.0423	-118.45502	PV2. CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM. SWITCHING 200A CIRCUIT BREAKER WITH NEW 225A CIRCUIT BREAKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20258	13041-10000-07130	643 S GLADYS AVE #403	90021	14	126A213   351	5147029045	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			Corrections Issued	03/19/2013 12:00:00 AM	ADDRESS	34.03936	-118.24314	PC FOR POWER. NEW SERVICE 800 A 120/240.3P4W AND SWBD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20259	14041-10000-17264	10340 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	08/25/2014 12:00:00 AM	ADDRESS	34.25824	-118.57961	PERMIT TO BE PULLED AT EPC COUNTER ONLY. PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT IN EXISTING SMART AND FINAL. BLDG#14016-10-12289	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20260	13041-10000-30055	5513 N VOLETTA PL	91607	2	174B161   578	2346001007	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.17069	-118.41123	PV1, Install 7 kW DC roof-mounted photovoltaic system for a 2 story house, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 28, power optimizer, modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20261	16041-10001-44613	10250 W SANTA MONICA BLVD # 1910	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE SHOWN DELTA 5  ON PLANS. REMOVE CENTRAL INVERTER AND USE UNIT EQUIPMENT INSTEAD. PERMIT ALREADY ISSUED. THIS IS PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20262	16041-20000-32230	23534 W HATTERAS ST	91367	3	174B093   126	2041009010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.17537	-118.63964	Plan check for a PV1 ground-mounted PV system. System size is 10 kWac and consists of (1) inverter and (32) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20263	19041-20000-52162	5329 N TOPEKA DR	91356	3	171B121   144	2163022021	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.16794	-118.54667	Plan check for PV roof mounted system, PV system size: 11.55KW DC, 10.43KW AC CEC with 33 PV Modules and 33 micorinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20264	18041-20000-11672	541 S SPRING ST Suite 129	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM			PC Approved	03/30/2018 12:00:00 AM	ADDRESS	34.04657	-118.2507	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 750 sq. ft.Note: Building application has been generated under 18016-10000-03573	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20265	13041-10001-32942	6941 N JELLICO AVE	91406	6	183B129   656	2229001004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.19674	-118.51752	Expedited RSES plan check per applicant request.[][]PV1, Install  4 kw DC roof-mounted solar array for a 1 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 16 modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20266	18041-10000-11912	333 S ALAMEDA ST UNIT#108	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.04448	-118.23824	PLANCHECK FOR T24 ENERGY.  T.I. (e) coffee shop. 255 SQFT.THIS IS PLAN CHECK ONLY!PERMIT UNDER 18041-10000-15471BUILDING PERMIT # 18016-30000-06811	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20267	13041-10000-26793	2126 W ADAMS BLVD	90018	10	123B193   653	5052032010	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Info Complete	10/28/2013 12:00:00 AM	ADDRESS	34.03248	-118.31281	pc for power only. New VFD and mini load center for FM O&G Murphy Drill Site.  Hazardous classifications. attached fault calculations to plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20268	10041-20002-24853	14712 W PARTHENIA ST #A1	91402	6	195B149   631	2653016054	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM			PC Approved	01/25/2011 12:00:00 AM	ADDRESS	34.22799	-118.45422	Plan check only. Supplemental application to include addtional lighting in T24 calculation and autoshut off.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20269	14041-20000-33910	8839 N ZEILER AVE	91331	6	195B153   701	2640023023	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.23032	-118.43264	PV1INSTALL ROOF MOUMNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(19) CANADIAN SOLAR CS6P-235PX MODULES(1) SOLAR EDGE SE3800 INVERTER(19) POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20270	11041-10001-26808	6161 N SEPULVEDA BLVD	91411	6	177B145   392	2242001011	M1-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.1821	-118.46652	PLAN CHECK FOR DELTA B REVISION TO APPROVED PLANS. CHANGES TO POWER AND EXTERIOR LIGHTING. PERMIT FOR ADDITIONAL 112.5KVA TRANSFORMER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20271	15041-10000-13559	2753 W WAVERLY DR BLDG.-#4	90039	4	151-5A207 233	5438025012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.10855	-118.26334	PHASE I:  (BUILDING #4 - 6 UNITS). CONSTRUCT NEW 3-STORY WITH ROOF DECK CONDOMINIUM.  ATTACHED TWO CAR GARAGE FOR EACH UNIT AT FIRST LEVEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20272	16041-10000-10068	2134 W SUNSET BLVD BLDG A	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.07723	-118.26485	"PC FOR POWER ONLY. SCOPE INCLUDES TWO NEW 120/208 3 PHASE 4 WIRE SERVICES, ONE FOR BUILDING ""A"" AND ONE FOR BUILDING ""B & C"".  CORE AND SHELL FOR EXISTING COMMERCIAL BUILDINGS.   BUILDING ""B & C"" IS FED BY MULTIPLE FEEDERS WHICH HAS BEEN APPROVED BY CODE VARIANCE SUBMITTED 9/30/2016."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20273	14041-20000-24396	11715 W BELLAGIO ROAD	90049	5	141B145   477	4368014034	[Q]R3-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.07869	-118.46956	PV2 APARTMENT ROOFTOP SOLAR. TOTAL SYSTEM SIZE 10KW AC USING 3 PHASE INVERTER WITH 4 STRINGS. TOTAL OF 60 MODULES. NON STANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20274	14041-20001-25880	5121 N COLBATH AVE	91423	4	171B153   579	2269007014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.16367	-118.43668	$0 plan check fee is due to State Senate Bill SB-1222.  Additional AC disconnect at front of house.  (((PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING CENTRAL TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20275	18041-20000-44394	24314 S ROSCOE BLVD pv1	91304	12	192B089   202	2017039013	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.21921	-118.65563	pv1install roof mounted pv system sized 5.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20276	16041-20000-31876	14851 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.2956	-118.45493	Plan check for roof-mounted solar array on SFD. Interconnect with 200A MSP.3kW ungrounded system. (11) 305W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20277	14041-10000-30274	189 S THE GROVE DR Ste K20	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	TI to (E) 2549 sq ft. commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20278	19041-10000-39193	5843 W PICO BLVD	90019	10	129B177   375	5086004028	C4-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			10/04/2019 12:00:00 AM	05/31/2023 12:00:00 AM		Issued	05/31/2023 12:00:00 AM	ADDRESS	34.05162	-118.36613	FULL PLAN CHECK FOR A NEW 6-STORY, 48 UNIT APARTMENTS OVER AN (E) SINGLE STORY COMMERCIAL BUILDING W/ BASEMENT PARKING. SCOPE INCLUDES 2 NEW SERVICES 1200a EACH. TOTAL AFFECTED AREA IS 15686 SQ.FTFIRE VARIENCE SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20279	18041-20000-23335	17448 W RUSHING DR	91344	12	219B129   541	2608032009	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/05/2018 12:00:00 AM	ADDRESS	34.2949	-118.51488	Plan check  for Battery back up system Tesla Powerwall installed to existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20280	13041-10000-35510	12255 N GERALD AVE	91344	12	216B137    22	2609014029	RE11-1	North Valley	Granada Hills - Knollwood		YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.2925	-118.49113	PV1, Install 6.75 kW DC roof-mounted solar array for a tw story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 6000A-US. (27) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20281	14041-10000-10037	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	new methane gas detection system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20282	13041-10000-35153	1804 E VERNON AVE BLDG D	90058	9	112-5A213  62	5106005009	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.00379	-118.24089	"T24 PART 6 ENERGY FOR (E) 19500 SQ FT COMMERCIAL SPACE BUILDING ""D"".  RETRO-FITTING 4' FLUORESCENT LIGHT FIXTURES WITH NEW F54T5HO LAMPS ONLY.  SCOPE OF WORK < 400A.  PERMIT IS EXISTING UNDER 11041-10001-21647.  NO NEW/MOVED WIRING PER APPLICANT, INSTALLATION NOT SUBJECT TO LIGHTING CONTROL REQUIREMENTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20283	13041-10000-11857	7939 S CHASE AVE	90045	11	099B161   453	4112009038	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	33.96723	-118.41233	PV1 for single story house.  Upgrading existing main service panel and connecting PV system to main service panel.  {19 modules: Yingli YL245P-29B}  {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20284	12041-20000-00734	20414 W HAYNES ST	91306	3	180B113   158	2136021017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2012 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.19263	-118.57817	pv system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20285	13041-20000-03224	3620 S VERMONT AVE #212, 214-216A	90089	9	120B197   929	5039002030	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.02213	-118.29133	T-24 lighting plan check only for a T.I. TO (E) OFFICE SPACE ON 2ND FLOOR (542 SQ FT);  REMOVE NON-BEARING PARTITIONS & UPGRADE W/NEW GLASS PANELS AT THE  ENTRY & OFFICE PARTITIONS; NEW FINISHES, OFFICE FUNITURE; NO CHANGE IN USAGE OR SQUARE FOOTAGE, NO STRUCTURAL WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20286	16041-10000-33465	1263 S WESTCHESTER PL	90019	10	129B189   916	5081020022	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM			Reviewed by Supervisor	09/29/2016 12:00:00 AM	ADDRESS	34.04776	-118.31885	Plan check for PV roof mounted system. System size: 15.2kW with 48 modules and 2 inverters(7.6kW ) connected to load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20287	14041-20000-25864	7625 N VAN NUYS BLVD	91405	6	186B149   109	2210031001	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.20911	-118.44904	"ADDITION OF  30'-2"" x 99'-6"" OFFICE USE,  CHANGE PORTION OF (E) RETAIL TO MEDICAL OFFICE, (30' X 85').   NEW 1000A SERVICE AND PANELS FOR VACANT SPACES."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20288	15041-20000-22334	1000 S CARMELINA AVE	90049	11	126B141   123	4264021031	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	01/27/2018 12:00:00 AM	ADDRESS	34.0441	-118.47284	Plan check for the addition of a 3 kWac system onto an existing 3 kWac system. Total system size is 6 kWac. New 3 kWac system consists of (1) inverter, (14) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20289	18041-10000-40482	6600 N TOPANGA CANYON BLVD SPC 49A-&B	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TITLE 24 ONLY. CHANGE OF USE FROM RETAIL TO RETAIL. NEW TENANT SPACE, ALL (E) ELECTRICAL AND SYSTEMS TO BE REMOVED AND NEW ELECTRICAL IS TO BE INSTALLED.building permit #18016-10000-32575*T.I. FOR CONSTRUCTION OF NEW NON LOAD BEARING WALLS; NEW MALL STOREFRONT; NEW FLOORING FINISHES; NEW FURNITURE AND FIXTURES; NEW OD OFFICE EQUIPMENT.*	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20290	18041-20000-13555	19191 S VERMONT AVE STE 480	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT WORK ON APPROX. 2223 SF OF THE TOTAL FLOOR AREA.BUILDING PERMIT # 18016-10000-08931	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20291	11041-20001-19865	1100 S GLENDON AVE 8th floor	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM			PC Approved	11/02/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	Modification to an approved set of plans.  Plan check is for energy only. <<<<<<T.I.  Remodel of light fixtures on the 8th floor.  Work to be done does not include the private offices.  Plan check is for energy only.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20292	17041-10000-44867	6086 W COMEY AVE	90034	10	123B173   299	5065012029	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Info Complete	12/28/2017 12:00:00 AM	ADDRESS	34.03516	-118.37692	"PC for energy only. TI to an existing office space. Scope includes adding new lights and receptacles. Total affected area is 3033 Sq. Ft. B#17016-30000-36461. ""COMPLY WITH DEPARTMENT ORDER effective date 12/14/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20293	19041-10000-39019	12712 W LANDALE ST	91604	2	165B161  1120	2362014196	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.15163	-118.40984	[Eplan] plan check for roof mounted 10.05KWDC/7.6KVAAC ROOFMOUNTED PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 30 MODULES USING P370 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20294	17041-20001-34189	15500 W VALLEY VISTA BLVD	91436	5	165B141   252	2285002037	R1-1	South Valley	Encino - Tarzana	Encino		1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM			PC Approved	10/01/2017 12:00:00 AM	ADDRESS	34.14955	-118.47273	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.162 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20295	17041-10000-02313	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.13829	-118.34154	FULL PLAN CHECK RENOVATION OF SOUTH CLUBHOUSE. 2 OF 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20296	19041-10000-35072	8307 N BLEWETT AVE	91343	12	192B141   464	2673018026	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.22168	-118.47995	[EPLAN] PLAN CHECK FOR ROOF MOUNTED(SE3800H-US) WITH 12 MODULES USING P320 OPTIMIZERS AND ESS(TESLA POWERWALL) CONNECTED TO EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20297	18041-10000-42097	108 W 2ND ST	90012	14	130-5A213 201	5149006901	C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM	ADDRESS	34.05097	-118.24511	TENANT IMPROVEMENT IN AN EXISTING RESTAURANT. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-29868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20298	19041-10000-31007	6725 W SUNSET BLVD	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.09814	-118.33717	PC FOR T24 ONLY SCOPE OF WORK IS A TI FOR A LOBBY AREA, NOT A HIGHRISE. SCOPE OF WORK INCLUDES NEW LIGHITNG, CONTROLS, CIRCUITS ARE EXISITING, TOTAL AFFECTED AREA IS 4839SQFT.FROM BUILDING: TI TO EXISTING 2948SF OFFICE SPACE AT GROUND LEVEL.  NEW EXTERIOR STOREFRONTS.  IMPROVEMENTS TO EXTERIOR COURTYARD AND SUNSET ENTRANCE INCLUDES NEW RAMPS, STAIRS, PLANTERS. RESTRIPE PORTION OF GROUND LEVEL PARKING GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20299	12041-20000-25969	619 S GAFFEY ST	90731	15	015B197   403	7451035026	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM			PC Info Complete	11/19/2012 12:00:00 AM	ADDRESS	33.73833	-118.29252	Plan check for energy and emergency lighting. LIttle Caesar's Pizza. 1392 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20300	16041-10000-42945	17178 W STRAWBERRY DR	91436	5	162B133    54	2292011045	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.14364	-118.50608	Plan check for PV roof mounted system. System size: 8.6kW with 37 modules and 2 inverters (5.0kW and 3.6kW) connected to MSP	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20301	18041-30000-17988	1800 N VINE ST 2ND FLR	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.10393	-118.3265	PLAN CHECK FOR T24 ONLY, TI ON 2ND FLOOR EXECUTIVE OFFICE SUITES, CORRIDORS, OFFICES AND BREAK AREA. TOTAL AREA: 17,010 SQ.FT, NEW CONNECTED LOAD < 200A(B# 18016-10000-14443)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20302	13041-20001-35999	7483 W PALO VISTA DR	90068	4	156B177   404	2427013007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/04/2014 12:00:00 AM	PIN	34.12315083	-118.35867799	((Expedite fees))PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20303	12041-10000-18053	940 W HARRY BRIDGES BLVD GUARD-HOUSE	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	05/10/2013 12:00:00 AM		Issued	05/10/2013 12:00:00 AM	PIN	33.77046453	-118.27163726	NEW GUARD HOUSE FOR PORT OF LA. EPC IS FOR POWER AND ENERGY. FIRE ALARM SYSTEM WAS SUBMITTED SEPARATELY.  (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20304	16041-10001-04889	1593 E 46TH ST	90011	9	112-5A213 257	5106011023	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.00195	-118.24569	Supplemental PC (revision to online permit # 16041-90000-04889, remove 1 module). PV1 rooftop installation 3.6 kW AC.(15) KU2656ZPA     (1) PVI-3.6-OUTD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20305	12041-10000-12767	7707 N LOMA VERDE AVE	91304	3	189B109  1090	2109021008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.21023	-118.58983	New 6kw rooftop, photovoltaic system, for an existing single family residence and a service upgrade.  System uses a transformer-less inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20306	14041-20000-33046	10844 W OLYMPIC BLVD	90064	5	126B157   334	4320001055	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.04394	-118.43122	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR JUICE PRESS. 930 SQFT, EMERGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20307	12041-10000-25902	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	Plan check for installation of fire alarm system. Existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20308	12041-10000-30381	3110 S MAPLE AVE	90011	9	118-5A205 175	5120018024	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Approved	12/18/2012 12:00:00 AM	ADDRESS	34.01917	-118.268	PLAN CHECK FOR TITLE 24, EMERGENCY LIGHTS AND EXIT SIGNS IN A RETAIL SPACE. CHANGE OF USE FROM WAREHOUSE AND PRINT SHOP TO RETAIL. EXISTING PANELS TO BE USED. ONLY LUMINAIRES WILL BE ADDED. LOAD LESS THAN 400A, NOT IN METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20309	12041-10000-03951	6801 W HOLLYWOOD BLVD suite 201	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			PC Approved	02/22/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	"REMODEL / RECONFIGURATION OF EXISTING STAIRS & COMMON AREA.  (SEPARATE PERMIT AND PLAN CHECK REQUIRED FOR FUTURE ""SWEET CANDY"" RETAIL SHOP)PLAN CHK IS FOR TITLE 24 AND 1 EM LIGHTING CIRCUIT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20310	16041-10000-41257	10250 W SANTA MONICA BLVD # 1630	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Bailey"" Ste. 1630.  Install new panels and its circuits, lights and receptacles. Total effected area: 1008 sq.ft.*Demand load 35A to DB-ELA41"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20311	13041-10000-34502	11125 W ALLEGHENY ST	91352	7	201B173    38	2538027019	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.25122	-118.37403	PV1, Install a 8.5 kw DC roof-mounted solar array system interconnect with main service panel with (2) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (34) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20312	16041-20000-00100	281 N BENTLEY CIR	90049	5	138B149    66	4366004018	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.07702	-118.45744	"""0$ fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 20.79 KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20313	12041-10000-17872	13421 W MAGNOLIA BLVD	91423	2	171B157   583	2344022019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM	09/06/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.16497	-118.42532	New 9.18kw rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20314	19041-10000-49003	3923 W 6TH ST 2ND FLR-4TH FLR	90020	10	135B193   862	5503019001	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	03/10/2020 12:00:00 AM		Issued	03/10/2020 12:00:00 AM	ADDRESS	34.06365	-118.30878	Energy plan check only for restroom . area of scope 960SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20315	15041-20001-37430	5550 N BONNER AVE	91601	2	174B173  1076	2350005052	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			12/19/2017 12:00:00 AM			PC Approved	07/09/2019 12:00:00 AM	ADDRESS	34.17145	-118.37398	12/19/2017changes to an approved set of plans.  changes are noted delta 1.  changes include redesign of common area layouts, energy calculations, and lighting.  updated fault current from utility and new AIC ratings for equipment.      (((((Plan check for power and energy. Project site is a new 5-story, 48-unit apartment building with (1) level of subterranean parking garage. Total lighting area = 40,475 sq. ft.Note: Building application has been created under 16010-10000-00385)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20316	16041-10000-06786	15838 W BAHAMA ST	91343	12	195B141   286	2672007006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.23272	-118.47775	PV1, INSTALL 17.658 KW DC/15200 W AC ROOD-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(54) MODULES: SUNPOWER SPR-327 -NE WHT-D(3) INVERTERS: POWERoNE pvI-6000& 5000 & 4200 W-OUTD-US-ANote: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20317	11041-20000-02176	4750 W WILSHIRE BLVD 2nd Floor	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM			PC Info Complete	02/15/2011 12:00:00 AM	ADDRESS	34.06185	-118.3338	T.I. for existing high rise building partial 2nd floor.  Install general/emergency lighting.  Plan check for energy.Note: Permit is under 11041-90000-02817.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20318	16041-20000-32831	11601 W WILSHIRE BLVD 6th Floor	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for energy only. New lighting (incl. emergency) for corridor, elevator lobby, and restrooms on 6th floor of existing high rise office building. 1,646sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20319	18041-20000-24155	13321 W MOORPARK ST	91423	4	165B157   295	2360013024	[Q]C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.1505	-118.42332	Plan check for Title 24 only in existing space T.I. Total area: 1200 sq ft. B#18016-10000-06888	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20320	15041-10000-20223	17700 W ROSCOE BLVD	91325	12	192B129   324	2101001001	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.22071	-118.51893	Full plan check for a new McDonalds restaurant with drive through  service.  Scope includes a new service of 1000-Amp ,120/208V, 3-phase 4-wire.  T-24 covers in/outdoor with a toatal area of 24,129-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20321	15041-10000-37272	1800 N BRONSON AVE	90028	13	150A191   355	5586028900	PF-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.10355	-118.31784	Energy plan check for an office T.I, Scope includes new lighting only; Total area is 2255-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20322	15041-10000-25564	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	PIN	33.92817449	-118.43220714	NEW ELECTRICAL ROOM WITH NEW 1200 AMP BOARD POWER BY STANBY GENERATOR TO POWER NEW PUMPS.  SITE IS IN METHANE ZONE LEVEL 2.  PLAN CHECK FOR HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20323	14041-20000-12560	725 S FIGUEROA ST 5th floor	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.04886	-118.26071	PLAN CHECK FOR ENERGY ONLYCommercial high rise building. TI for conference room on 5th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20324	18041-10001-02129	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	33.94248	-118.40461	SUPPLEMENTAL CHANGES TO APPROVED SET,  ADDITION OF 120 SQ FT AND 10 NEW BRANCH CIRCUITS, NEW TOTAL SQFT = 85160	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20325	17041-20000-39620	9841 N AIRPORT BLVD 15th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Issued	11/02/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20326	19041-10000-02550	5901 W CENTURY BLVD 400	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	TENANT IMPROVEMENT ON THE 4TH FLOOR OF EXISTING OFFICE BUILDING IN SUITE # 400.INSTALLING NEW LIGHTS. TITLE 24 - ONLY. BUILDING PERMIT: 18016-10000-15921	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20327	13041-20000-14002	16459 W CALAHAN ST	91343	12	198B137   852	2676020008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.23676	-118.49134	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.76KW. 16 MODULES. using enphase m215	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20328	14041-10000-30874	136 S VIRGIL AVE	90004	13	138A201   178	5501017045	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			11/06/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.0724	-118.28659	11-06-14   M.Z SINCE  ALL DEVICES CHANGED  THERE FORE NEW APPLICATION IS SUBMITTED AND EXPEDITED.  14041-10000-25391  OLD APPLICATION  #   )))))))))))))))))))))))         INSTALLATION OF A NEW FIRE ALARM SYSTEM. NEW FACP WITH 156 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20329	12041-10000-03519	9540 N VAN NUYS BLVD	91402	6	201B149   735	2644025901	P-1VL, RD2-1, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.24411	-118.45004	Plan check for T24 Energy/Emergency lighting for City of LA Multipurpose Center. Indoor and outdoor lighting. Building less than 100 occupants.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20330	11041-10000-15436	231 E 3RD ST	90012	14	129A213    90	5161025013	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			07/22/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	PIN	34.04849177	-118.24373053	TI TO THE PARKING GARAGE AND COMMON AREAS OF AN EXISTING APARTMENT COMPLEX.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20331	15041-10000-21816	10828 S LOU-DILLON AVE	90059	15	088-5A215 174	6068004014	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	33.93727	-118.23473	PV 2, ROOF MOUNTED SOLAR, 3KW SYSTEM (1) INVERTER: PVI-3.0-OUTD-S-US-Z-A(14) MODULES: KYOCERA #KU2606XPAPERMIT FEES PAID UNDER APP. # 15041-90000-15136 (THIS APPLICATION FOR P.C ONLY)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20332	12041-10001-31179	17015 W DEVONSHIRE ST	91325	12	204B133   170	2695020033	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.25768	-118.50301	(((8/19/2014 - Supp. app. for title 24 only.  Change of outdoor lighting fixtures from original plan.  All changes clouded with delta 3)))Master permit work description: CHANGE FROM MEDICAL BUILDING TO CHURCH/SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20333	13041-10001-33104	19511 W TRIBUNE ST	91326	12	207B117    77	2708006006	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.26689	-118.55788	Expedited RSES plan check per applicant request.[][][]PV1, Install 7.5 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE6000A-US. (30) modules Hanwha HSL60P6-PB-4-250TW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20334	15041-10001-25165	707 W WILSHIRE BLVD 3280	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM			PC Approved	08/12/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI to (E) commercial office space on the 32nd floor of an (E) highrise office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20335	14041-10000-19981	17825 W DEVONSHIRE ST 1-24	91325	12	204B129   154	2733001012	(T)(Q)RAS3-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.25768	-118.52255	FA FOR 24 UNIT APT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20336	16041-10000-08075	1063 W VIA CORDOVA	90732	15	021B193    75	7445017014	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	33.75467	-118.30196	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. SCOPE INCLUDES ADDING A 8.6KWac SYSTEM TO AN EXISTING 6.0KWac SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 14.6 KWac. (35)MODULES-SILEVO #TRIEX U300 BLACK(2)INVERTERS- PVI-5000-OUTD-US-Z-A AND PVI-3.6-OUTD-S-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20337	16041-20000-01245	5310 N DAHLIA DR	90041	14	163-5A227  48	5669011023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.14391	-118.19967	Plan check for PV roof mounted system. System size: 6.0kW with 22 modules connected to 200A panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20338	14041-20000-02340	18590 W BRYMER ST	91326	12	213B125   213	2872018002	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.28183	-118.53825	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20339	18041-10000-35994	2231 S BARRINGTON AVE	90064	11	123B149   480	4260012027	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.03337	-118.44727	FULL PLAN CHECK FOR POWER AND ENERGY FOR - CHANGE OF USE FROM (E) WAREHOUSE/RETAIL TO COMMERCIAL OFFICE SPACE AND STUDIO W/OUTDOOR PATIO - TOTAL AFFECTED AREA = 25458 SF WITH APPROX 450A OF CONNECTED LOAD .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20340	19041-20000-02047	8352 N COOPER PL	91306	3	192B109   955	2780005077	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.22201	-118.58696	addition of (2) tesla batteries 5KW each to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20341	10041-10000-04715	13203-13225 N GLADSTONE AVE	91342	7	225B157   700	2509016011	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.31052	-118.42831	AT A STRIPMALL, REPLACING SWBDS MSA; MSB; MSC  ( ALL AT 85KAIC ) AND TENANT PANELBOARDS ( ALL AT 65 KAIC ). OLD SWBDS AND PNL BDS ARE REMOVED AND NEW BDS PUT IN THERE PLACES. THIS IS ANTICIPATION THAT THE SERVICES TO THE STRIPMALL WILL BE UPGRADED LATER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20342	15041-10001-01452	9020 S LOYOLA BLVD	90045	11	096B161   796	4119039001	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	33.95689	-118.41784	SUPPLEMENTAL #15041-10000-01452 FOR CHANGE OF ADDRESS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20343	16041-10000-43006	1711 E SLAUSON AVE	90058	9	108B213   674	5105021030	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	33.98968	-118.24274	PC FOR SERVICE UPGRADE. INCREASE FROM 400A TO 600A. REFEED EXISTING 400A AS SUBPANEL. CHECKING NEW AIC RATING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20344	11041-10000-00086	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	03/10/2011 12:00:00 AM	ADDRESS	34.17307	-118.59314	400kw optional standby generator  with a 600A  ATS-3poles TO PROVIDE BACK-UP POWER TO THE UTILITY AND TO EXISTING 200KW GENERATOR SUPPLYING A UPS SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20345	19041-20000-50295	110 E 9TH ST 8th Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TI to commercial tenant spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20346	13041-20002-30907	1416 N LA BREA AVE	90028	4	147B181   794	5548017021	[Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.09656	-118.34388	EXPEDITE FEES ONLY.<<<New 199KW rooftop PV system for an existing commercial building.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20347	14041-20000-09044	7323 N VENTURA CANYON AVE	91405	2	186B157   471	2328003008	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks			1271.03	Electrical	Electrical	Apartment			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.2037	-118.42926	PV1.  Install 3.45 kW AC roof-mounted PV system, interconnect with upgraded main service panel.  Microinverter standard plan.  Microinverter: Enphase M215-60-2LL.  16 modules: Solar World SW255-MONO	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20348	16041-20000-14720	13545 W BRANFORD ST	91331	6	195B157   610	2640032008	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.2306	-118.42759	PV1.  Install 5.70 kW roof-mounted PV system.  Central inverter standard plan.  (20) 285 W modules with (1) 5000 W rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20349	17041-10000-34153	4845 W FOUNTAIN AVE	90029	13	147B197  1088	5543019009	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.09551	-118.29518	PC FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA  2310 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20350	15041-10000-22823	5422 W CARLIN ST #2	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/30/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	PV1, INSTALL 3.445 KW DC ROOF-MOUNTED SOLAR ARRAY ON COMMERCIAL BUILDING.(13) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20351	19041-10000-29017	1475 S ROBERTSON BLVD	90035	5	129B169   274	4305014078	C2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.05254	-118.3842	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM CONTROL PANEL WITH 65 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20352	17041-10004-33475	11924 W FOOTHILL PL	91342	7	210B165   107	2532012038	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	PIN	34.27497571	-118.39643615	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 3 ONLY. CHANGES ON FUSES, DISCONECT SIZES, BREAKERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20353	14041-20000-21013	7251 N HESPERIA AVE	91335	3	186B125   906	2121002017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.20265	-118.52638	New roof mounted PV system with Enphase model M250-60-2LL.  Total system size 4.86KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20354	10041-20000-05816	6708 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	34.11762	-118.33861	installing emergency lighting and exist sign in apartment condominium.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20355	12041-20000-24946	8931 W ELLIS AVE	90034	10	123B169  1440	4312011006	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.02949	-118.38998	PC FOR ENERGY ONLY. NO EMERGENCY LIGHTING PER APPLICANT. LOAD IS LESS THAN 400 A. FLOORS 1-3 OF A THREE STORY BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20356	12041-10000-24182	1036 S CORNING ST	90035	5	132B173   491	4332030007	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM			PC Info Complete	04/17/2013 12:00:00 AM	ADDRESS	34.05827	-118.37715	CONSTRUCTION OF A NEW EARLY CHILDHOOD CENTER (ECC) PRESCHOOL FACILITY WITH ONE UNDERGROUND PARKING LEVEL IN THE  [Q]R3-1-0 ZONE, AS A PROPOSED EXPANSION OF ACCESSORY SCHOOL USE TO THE EXISTING TEMPLE BETH AM SYNAGOGUE AND PRESSMAN <SEE COMMENTS>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20357	17041-10000-24504	11260 W HARTLAND ST	91605	2	183B173   199	2319005031	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.19517	-118.37679	Plan check for Title 24 only in existing space, replace outdoor existing fixtures with LED fixtures. Total area: 41,400 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20358	13041-20001-25612	7479 N WESTCLIFF DR	91304	12	186B089   312	2027045013	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	PIN	34.20703816	-118.64845321	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.6 KW AC USING TRANSFORMERLESS INVERTERS. 2 CENTRAL INVERTERS. 4 STRINGS/ INVERTER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20359	16041-10001-37707	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	02/09/17Changes to an approved set of plans. All changes are clouded under Delta 1. replacing lights and adding track lighting. Note: permit is paid under PCIS#16041-10000-37707b#16016-10000-25376	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20360	13041-20000-30033	12209 W SANTA MONICA BLVD	90025	11	126B145   732	4263027019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.04028	-118.46511	Change to lighting and receptacles in an existing Dental Office.  Full plan check for power and energy.  Not state licensed, NOT OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20361	16041-20000-10318	1446 S ARMACOST AVE 1-9	90025	11	126B145  1225	4263032049	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	10/08/2016 12:00:00 AM	ADDRESS	34.04284	-118.46087	"""0$ permit fees due to senate bill 1222 ""PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 40KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20362	11041-10000-04436	8835 N SHIRLEY AVE	91324	12	195B117    65	2783025044	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Finaled	05/29/2012 12:00:00 AM	ADDRESS	34.23086	-118.55806	BURNED DOWN BUILDING, BEING REBUILT TO NEW.  TWO SEPERATE TENANT SPACES WERE COMBINED WITH DUPLICATE SERVICE.  SINGLE STORY, BEING USED AS A WAREHOUSE W/ OFFICE SPACE.  FULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20363	19041-20000-15593	2929 1/2 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Closed	11/05/2021 12:00:00 AM	ADDRESS	34.10433	-118.24396	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20364	14041-20001-17276	5616 N FARRALONE AVE	91367	3	174B101   227	2146008255	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.17259	-118.61007	((EXPEDITE FEES))PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. CONNECTED TO 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20365	12041-20001-20569	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.24317	-118.50383	Modification to approved plans.  Changes to feeders, panels, to each building.  Plan check only for DELTA 1.         <<<<Service upgrade at existing building, provide feeder services to two other existing buildings, and install photovoltaic systems to the new service equipment.  plan was approved earlier, but modification were required due to DWP renovation requiements.  Fees for modules were covered under previous submittals (12041-20000-10456)>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20366	15041-10001-27869	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.06725	-118.41704	CHANGES TO SINGLE INE DIAGRAM : REPLACING MAIN CIECUIT BREAKER FROM 1200A TO 600A;REMOVING SEALS  FROMCONDUITS TO MCC .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20367	19041-10001-18969	1262 E PALMETTO ST 1ST FLR-STE 515	90013	14	126A217    44	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Info Complete	11/25/2019 12:00:00 AM	ADDRESS	34.04005	-118.23347	Change to an approved set by modifying the lighting plan; all changes under delta-3 only.(((FULL PC (PWR AND ENERGY) FOR FIRST TIME USE OFFICE/RETAIL -  SCOPE INCLUDE ADDING NEW PANEL , EXISTING SERVICE IS 1600A,277/480V. AREA OF SCOPE IS 9,645SF. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20368	18041-20001-36377	10545 N TUJUNGA CANYON BLVD	91042	7	207B197  1263	2557018015	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			PC Approved	10/23/2018 12:00:00 AM	ADDRESS	34.26076	-118.29338	Revisions to approved plans.  Change of wiring details throughout.  (((Plan check for a PV1 roof-mounted PV system. System size is 10.24 kWac and consists of (32) AC PV modules and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20369	12041-20000-15904	9730 N INDEPENDENCE AVE	91311	12	201B109   169	2746002012	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.24727	-118.5906	Replace emergency generator from 31KW to 62 KW.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20370	12041-10000-01381	9189 N DE GARMO AVE	91352	6	198B173   125	2408034042	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM			PC Approved	01/20/2012 12:00:00 AM	ADDRESS	34.23604	-118.37603	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE BUILDING ADDITION. EXISTING SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20371	15041-10004-01167	6944 S KNOWLTON PL	90045	11	102B173   375	4103013008	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			10/23/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	33.97371	-118.37115	PC FOR REVISION TO APPROVED SET UNDER DELTA 1SCOPE INCLUDES CHANGE TO FIXTURE TYPE INSTALLED IN THE CORRIDOR ON 2ND TO 4TH FLOORS AND LOBBY AND OFFICE ON 1ST FLOOR  AREA.REVISIONS TO TITLE 24 AND PANEL SCHEDULES.THIS IS PLAN CHECK ONLY!PERMIT UNDER ORIGINAL. .  Regular plan check for power and energy. Project is a new 4-story, 36-unit multi-dwelling building with a grade level parking garage. There are 3 typical units. Total lighting area = 21,000 sq. ft.NOTE 1: Title 24 compliance forms to be brought in at later date.NOTE 2: Applicant came in with a pre-cut check. Fees were adjusted so that the fees were below the amount. Fees to be adjusted before the permit is issued. Fees are to be increased by (69) general branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20372	16041-20000-18109	1605 1/2-1607 N LA BREA AVE	90028	4	147B181   392	5548008049	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			PC Approved	05/23/2016 12:00:00 AM	PIN	34.09999546	-118.34494146	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CHANGE OF USE FROM RETAIL TO MASSAGE PARLOR. 1250 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20373	17041-20000-03794	20294 W LORENZANA DR	91364	3	171B113   339	2166039006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.16387	-118.57624	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (30) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20374	19041-10000-28687	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Issued	07/25/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	PC for T24 only per inspectors request, scope of work includes new lighting and controls and equipment in a conscession stand #28. Total affected area is 1007 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20375	10041-10000-14706	11400 W ROCHESTER AVE Bldg 5	90025	11	129B149   103	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Corrections Issued	10/07/2010 12:00:00 AM	ADDRESS	34.04842	-118.45404	NEW SERVICE, PANELBOARDS AND CIRCUITS FOR 10 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20376	19041-20000-45699	2137 S CLOVERDALE AVE	90016	10	126B177  1374	5063009079	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.03845	-118.35513	PV1. INSTALL 2.48 KW DC PV SYSTEM WITH (8) MODULES/OPTIMIZERS AND (1) INVERTER(SE3800H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20377	16041-10000-04748	23626 W VANOWEN ST	91307	12	180B093   104	2036026003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.19302	-118.64123	PV150amps. Installation of a roof-mounted solar PV system using central Inverters. Total size is 5KW. (18) modules and and (1) Inverter 5KW. Main breaker is being derated to 150 amps.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20378	18041-10000-34322	1426 S HAYWORTH AVE 1-8	90035	10	129B173   575	5068017016	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.05069	-118.36762	NEW FIRE ALARM SYSTEM TO A LOW RISE APARTMENT BUILDING. TOTAL OF 1 FACP, 55 FA DEVICES, AND 16 CONTROL DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20379	13041-10000-26795	6430 W SUNSET BLVD UNIT #455	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.09782	-118.32979	TITLE-24 ONLY FOR EXISTING PRIVATE OFFICES. TOTAL SF AREA WILL BE 1100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20380	12041-10000-18794	5340 S ALLA ROAD	90066	11	102B157    39	4211008023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	33.9773	-118.42567	Power and circuits for a new elevator in an existing 2-story commercial building.  Building is in a methane site.  No circuits penetrate any methane barrier.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20381	13041-20000-14975	13697 N BADGER AVE PV-1	91342	7	228B157   631	2511021012	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.32087	-118.42057	PV-1. Plan check for PV. Transformerless. 3.6kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20382	10041-20000-10703	11111 W SANTA MONICA BLVD s.620	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles			2673.00	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM	06/07/2010 12:00:00 AM		Permit Finaled	06/24/2010 12:00:00 AM	ADDRESS	34.04771	-118.44481	s.620 office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20383	16041-10000-17669	19328 W NASHVILLE ST	91326	12	210B117   280	2718023015	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.26912	-118.55482	PV2. NEW SOLAR SYSTEM FOR AN EXISTING RESIDENTIAL ROOF-TOP. TOTAL  SYSTEM  SIZE IS 12.7 KW(AC)  INCLUDING 40 PANELS    SUNPOWER SPR327NE-WHT-D 2 INVERTERS SMA SB7700TL-US-22   SMA SB5000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20384	14041-10001-32855	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM			PC Approved	03/20/2015 12:00:00 AM	ADDRESS	34.07583	-118.37407	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES CLOUDED DELTA 5.  CHANGES INCLUDE LIGHTING AND LOCATION OF POWER EQUIPMENT.Plan check for power and energy. T24. Total area = 1694 sq. ft.   Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20385	11041-20000-25349	1110 S GLENVILLE DR	90035	5	132B169   510	4332002045	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			11/29/2011 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	12/26/2013 12:00:00 AM	ADDRESS	34.05675	-118.39261	New 24 unit apartment building.  Full plan check.  A variance has been filed to separate the fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20386	16041-20000-21978	6033 N DE SOTO AVE	91367	3	177B105    63	2149005032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.18008	-118.59079	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT TO RESTAURANT.  520 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20387	14041-10000-01522	500 WORLD WAY T5-INFLIGHT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	33.94248	-118.40461	PLANCHECK FOR STAMPING EXTRA PLANS.TENANT IMPROVEMENT IN OFFICES PLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS. SCOPE OF WORK IS < 400A . PLAN-CHECK ONLY PER SUPERVISOR. PERMIT TO BE PULLED @ THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20388	12041-20000-11022	445 S FIGUEROA ST STE 3200	90017	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.00, 2077.10	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	05/23/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	PIN	34.0533007	-118.2570441	Tenant improvement for office. Plan check for energy and emergency lighting. 6943 conditioned sqft. Commercial high-rise. 32nd FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20389	15041-10000-32154	20750 W NORDHOFF ST BLDG 5	91311	3	198B109   220	2780001***	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.23522	-118.58548	NEW FIRE ALARM SYSTEM. THERE IS 4 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL,  AND 1 COMMUNICATION PANEL. SOME FEES PAID UNDER EXPRESS PERMIT PCIS#15041-10000-10950.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20390	18041-20000-33513	3397 N BARHAM BLVD	90068	4	159B181   187	5579007022	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	06/11/2021 12:00:00 AM	ADDRESS	34.1333	-118.34402	Plan check for new fire alarm system for commercial building, Total fire alarm devices: 48 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20391	17041-20001-45534	13571 W VAUGHN ST	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.27758	-118.42846	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2217.53 KW.  PV system is a feed and tariff system. RESUBMITTAL TO EXPIRED PLANS 15041-20000-08646(5614)  LG395 395 WATT MODULES(30) SMA 24(23) SMA 23(18) SMA 1857BUILDING PERMIT # 15016-20000-20234	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20392	13041-10000-05461	4550 W PICO BLVD C320	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Closed	12/01/2017 12:00:00 AM	ADDRESS	34.04842	-118.33486	"FIRST TIME TENANT. NEW CHASE BANK. PLAN CHECK FOR POWER AND ENERGY. <<""COMPLY WITH DEPARTMENT ORDER effective date 06/17/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20393	18041-10000-03876	817 W 101ST ST	90044	8	091-5A199 160	6054009013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	33.9447	-118.29001	PC FOR ROOF MOUNTED PV ON SLD. SCOPE INCLUDES 26 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.SYSTEM SIZE 5.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20394	18041-10000-03399	1737 E DENNI ST	90744	15	033B213   257	7428006006	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.78595	-118.24027	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20395	11041-20000-21333	601 S FIGUEROA ST 42ND FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT TO EXISTING SPACE ON 42ND FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20396	14041-20000-10163	4520 N VAN NUYS BLVD	91403	4	168A151   188	2265013025	C2-1VL, P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM			Corrections Issued	04/17/2014 12:00:00 AM	ADDRESS	34.15371	-118.4485	Relocate (4) parking lot light poles.  Add (3) new parking lot lights.  Add (1) circuit for future monument sign under separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20397	13041-10001-06017	9301 N TAMPA AVE UNIT 192	91324	12	198B117    99	2761037004	R1-1	North Valley	Reseda - West Van Nuys	Tarzana		1133.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	05/01/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	Changes to approved set.  Changes to fixture schedule and title 24 forms to reflect current design lighting.  Original Description: PC FOR TITLE 24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT FOR RETAIL/MERCANTILE SPACE. SQUARE FOOTAGE IS 4561. NOTE: ALL PERMITS FOR TITLE 24 APPLICATIONS SHALL BE OBTAINED THROUGH ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20398	18041-20000-37522	6600 N TOPANGA CANYON BLVD #1084-E	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Closed	07/22/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 Energy only in existing retail space T.I. Total area: 1805 sq ft. B#18016-20000-31853	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20399	15041-10000-05474	18701-18729 W REDWING ST	91356	3	174B121   812	2161026005	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			02/25/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.16963	-118.54066	NEW FA SYSTEM  FOR 15 APARTMENT UNITS. 30 FA DEVICES AND FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20400	13041-10000-00476	7266 W 90TH ST	90045	11	096B157   939	4119032021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2013 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	33.95567	-118.42096	PV1:  New 6.48 KW roof mounted PV system for a single family residence usinf the ENPHASE M215 microinverter.  Applicant is using the standard plan and is installing 30 REC PEAK ENERGY BLK SERIES modules (REC 245 PE) and 30 microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20401	17041-10000-18196	10250 W SANTA MONICA BLVD # 1610	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Info Complete	07/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	full plan check, First tenant- TakeABao Restaurant ste. 1610	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20402	12041-10000-14800	16830 W VENTURA BLVD # 401	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check T24 Energy/Emergency lighting  for office T.I. at 4th floor suite #401. Permit on #12041-90000-11335	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20403	19041-20000-30335	7810 N TOPANGA CANYON BLVD	91304	3	189B101   648	2110012054	(Q)RD1.5-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Apartment			08/05/2019 12:00:00 AM	06/09/2021 12:00:00 AM		Issued	06/09/2021 12:00:00 AM	ADDRESS	34.21218	-118.60573	TI REMODEL OF EXISTING APARTMENT BUILDING. UPGRADE OF SERVICE EQUIPMENT IN METER ROOM #1 TO 600A AND UPGRADE (26) UNIT PANELS TO 100 AMPS AND ADDITION OF SOME NEW LOADS TO UNIT PANELSPHASE 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20404	14041-20000-14631	10540 N MELVIN AVE	91326	12	207B117   390	2708005028	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.26173	-118.55982	Roof mounted PV system with transformerless inverter.  System size is 8.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20405	16041-20000-03733	3636 S CAROLINA ST	90731	15	006B197   790	7467015029	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2976.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	33.71089	-118.29049	PV1.  Permit previously finaled under 15041-90000-38480.  Change of inverter from single phase to three phase type after finaling.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20406	15041-10000-16395	12515 W OSPREY LANE #3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	33.97893	-118.41131	((((5/28/2015))))PV1 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 3 SIZED 1.84KW INTERCONNECTED WITH MSP.PERMIT FEES UNDER APPLICATION NUMBER 14041-20000-19528.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20407	12041-10000-18987	15509 W SEPTO ST	91345	7	201B145    74	2660006029	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.25109	-118.47017	Plan check for new roof mounted 3.92KW photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20408	18041-20000-17050	9418 W BOLTON ROAD	90034	5	126B165    55	4309013009	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.04518	-118.39388	Plan check for PV roof mounted system, System size: 15.12kWac with 42 AC Modules connected to 400A MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20409	15041-20000-20373	2121 S AVENUE OF THE STARS #2000	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Apartment			06/29/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check Title 24 only for FNG Innovation in exist office high rise building. Total lighting area: 2,845SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20410	12041-10000-27519	123 S ASTRONAUT ELLISON S ONIZUKA ST	90012	9	130-5A213 128	5161016028	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Expired	12/23/2014 12:00:00 AM	ADDRESS	34.05019	-118.24211	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS ON A TENANT IMPROVEMENT FOR A RETAIL STORE (1449 SQUARE FEET).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20411	19041-10000-04952	2801 W SUNSET PL	90005	10	133-5A201  35	5077013040	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2122.04	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	03/01/2022 12:00:00 AM	ADDRESS	34.0609	-118.2845	NEW FIRE ALARM SYSTEM FOR A HIGH RISE COMMERCIAL BUILDING. TOTAL OF FA DEVICES 2425 AND 32 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20412	15041-30001-42241	19159 W WELLS DR	91356	3	171B121   339	2163009018	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			Corrections Issued	01/07/2016 12:00:00 AM	ADDRESS	34.16481	-118.5507	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 15.2 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20413	14041-20000-09277	19700 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	33.85221	-118.2903	TI for commercial classroom and laboratory space in a two story commercial building.Plan check for Title 24 due to changes in lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20414	18041-20000-24195	2414-2414 1/2 N NORTH BROADWAY	90031	1	138A221    96	5204005006	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.07345	-118.21631	Plan check for Title 24 only in existing space T.I. Total area: 1225 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20415	16041-20001-15082	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	33.79072	-118.29449	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM ON A CARPORT.  SYSTEM SIZE: 332 KW . LINE SIDE TAP.1024  MODULES BUILDING PERMIT # 16014-20000-01950 , 16010-20000-01727, 16010-20000-01728PLANS HAVE GROUNDMOUNTED SYSTEM AND CARPORT SOLAR ROOFMOUNTED SYSTEM ON SAME PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20416	15041-20002-03040	14540 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	34.23519	-118.44926	2/26/2015 - Supplemental application for changes to approved set.  Title 24 only.  Relocation of some lights outside of daylight zone and removal of photocontrols.  Removal of occupancy sensor.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO DOLLAR KING. 8700 SQFT, EMERGENCY LIGTHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20417	14041-10000-21826	845 N BUNKER HILL AVE	90012	1	135A213   132	5407007010	R4-1	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Apartment			08/13/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.06449	-118.24277	Title 24 plan check only.  Renovatin to common areas in existing 18 unit apartment building.  Indoor and outdoor lighting.  total area = 3,820 sq. ft.Building permit: 14016-20000-01401Application submitted before title 24 part 6 effective date	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20418	19041-10000-36941	18321 W CLARK ST	91356	3	174B125   453	2160011031	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Closed	11/30/2023 12:00:00 AM	ADDRESS	34.16988	-118.53123	TEMPORARAY POWER FOR NEW OSHPD 1 BUILDING. SCOPE INCLUDES 1600A 480V, 3PH, 4W SERVICE AND ASSOCIATED EQUIPMENT. B#19020-10000-01386	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20419	12041-10001-16076	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.10158	-118.3062	PLANS CHANGED FROM TWO SERVICES TO ONE SERVICE, ALSO ONE PANEL TO THREE PANELS, LOCATION OF TITLE 24 CHANGED.Plan check for energy and power. Restaurant. Single story commercial. 120 occupants per applicant. 4653 sqft. Parasolnine Thai Restaurant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20420	19041-10001-04281	604 W C ST	90744	15	027B205   232	7417019921	OS-1-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	33.77218	-118.26861	DELTA 1 CHANGES TO AN APPROVED SET. REMOVING 1 SMOKE DETECTOR FROM A MATHANE DETECTION SYSTEM AND CHANGING THE NAME OF THE FACP TO MMP. PC ONLYoriginal scope ((PC FOR REPLACING (1) OBSOLETE METHANE SYSTEM MONITORING PANEL WITH NEW MODEL))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20421	18041-20000-48661	19243 W SANTA RITA ST pv1	91356	3	171B117    82	2163011017	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2018 12:00:00 AM	12/24/2018 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.16773	-118.5524	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20422	19041-20001-07146	411 S VIRGIL AVE	90020	13	135B197   628	5077002034	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM			PC Approved	05/06/2019 12:00:00 AM	ADDRESS	34.06621	-118.28724	Expedited plan check fee.PV2.  Install 21.96 kW roof mounted grid tied PV system.  (61) modules with (2) 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20423	19041-10000-14923	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	ADDRESS	34.06237	-118.35809	TENANT IMPROVEMENT FULL PLAN CHECK POWER AND ENERGY. SCOPE INCLUDES EXISTING PANELS, NEW EQUIPMENTS, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 11523 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20424	13041-10002-34169	547 S WESTERN AVE	90020	4	135B193   818	5503018019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM			PC Approved	03/07/2014 12:00:00 AM	ADDRESS	34.06397	-118.30938	Modifications to approved set.  Change of fixture types to LED for customer-serving spaces.(((PLAN CHECK FOR T24 ENERGY ONLY. BEAUTY SALON. 1132 SQFT. EMERGENCY LIGHTING. > 400 AMPS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20425	15041-10001-07124	335 N MARIPOSA AVE APT # 3	90004	13	138B197   132	5520025012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	07/23/2015 12:00:00 AM	ADDRESS	34.07733	-118.29968	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20426	19041-20000-45656	9607 N LEMONA AVE	91343	7	201B145   570	2650002021	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Issued	11/06/2019 12:00:00 AM	ADDRESS	34.24482	-118.45898	PV1.  Install 12.16 kW roof mounted grid tied PV syste.  (38) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20427	10041-10000-01674	2117 W TEMPLE ST	90026	13	138A205   278	5157016031	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10, 2085.00	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM	03/24/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.07062	-118.26858	New fire alarm system for building A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20428	16041-10000-44126	10751 W RIVERSIDE DR	91602	4	165B177    46	2423001007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Mid-Town North Hollywood		1431.00	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.15241	-118.36536	"PC for power and energy for change of use from Office to Dental Office. Dental office to perform non-invasive procedures. Total sqft is 2270sqft.Building permit under 16041-20000-00980.**CHG OF USE FROM OFFICE TO DENTAL OFFICE AND NEW WINDOWS; STOREFRONT; NEW FACADE;  ADA RAMP.  NEW BICYCLE PKG;  NEW ROOF FRAMING.   ""Canopy removed"""	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20429	16041-20000-18228	12308 W CANTURA ST	91604	2	162B165   395	2369003030	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.14201	-118.40121	PV1.  Install 7.6 kW roof mounted PV system.  Comprehensive central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20430	15041-10001-04103	307 W 4TH ST	90013	14	130-5A211 156	5149015023	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	34.04986	-118.24968	((((6/1/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2.  CHANGES INVOLVE REVISIONS TO THE LIGHTIGN FIXTURES ENERGY CALS AND PANEL SCHEDULES.  Plan check for Powe and Energy, for Restaurant Bar/Lounge. Total area: 6463 sq ft. (power plan check per FY) T-24 code based on 2008	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20431	10041-20000-24661	9118 N BALBOA BLVD	91325	12	198B133   568	2687004016	C2-1VL, P-1VL	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.23656	-118.50231	Plan check for replacing (2) single phase 600A and (1) 600A 3-phase service to new 2000A service and main switchboard. All panels and loads in building are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20432	17041-20000-09396	10362 N PETIT AVE	91344	12	204B137    92	2684005008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2017 12:00:00 AM			Reviewed by Supervisor	04/05/2017 12:00:00 AM	ADDRESS	34.25931	-118.49781	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20433	14041-10000-24484	13286 W TERRA BELLA ST	91331	7	204B157   768	2623004012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.25526	-118.42226	PV1, INSTALL 3.315 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(13) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20434	13041-10000-30731	240 E 6TH ST	90014	14	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.0435	-118.24761	TI for spaces 102B, 102C & 102D on the first floor of a mixed used building (residential + commercial).        Variance was issued for 30 day demand reading on 4/30/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20435	11041-10000-15191	1633 E SLAUSON AVE	90011	9	108B213   736	5105020032	MR1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	33.98948	-118.24436	NEW 3208 SQ FT ONE STORY BUILDING FOR AUTOMOBILE REBUILDING AND RECONDITIONING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20436	18041-20000-03870	11907 W WICKS ST	91352	6	198B169   179	2631004017	(T)(Q)M1-1-CUGU, (T)(Q)P-1-CUGU, [Q]M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	ADDRESS	34.23496	-118.39267	service upgrade 800 amps.  reconnect existing loads.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20437	18041-10000-40159	550 S HOPE ST 2000	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLANCHECK FOR T24 ENERGY ONL.Y TENANT IMPROVEMENT TO (E) OFFICE SPACE (1985 SQ FT).  HIGH RISE. SUITE 2000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20438	13041-10000-12841	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.15777	-118.43065	FEES TO BE RECALCULATED since applicant brought check already. pc for power and energy. power and lighting for concessions  and lockers.  notre dame high school . non-methaneBASEBALL STADIUM/ RET WALL & SCOREBOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20439	13041-10000-18224	912 E 12TH ST D	90021	14	123A211   151	5132013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	ADDRESS	34.03176	-118.24942	PLAN CHECK FOR TITLE 24 PART6 ENERGY FOR A TENANT IMPROVEMENT, RETAIL. UNIT SPACE D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20440	14041-20000-27125	23660 W NADIR ST	91304	12	192B093   433	2005018035	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	34.21962	-118.64312	PV1Install roof-mounted solar array on SFD. System size: 7.74kW.(36) EnPhase M215-IG microinverters(36) SolarWorld Poly SW250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20441	19041-10000-08327	6160 N LAUREL CANYON BLVD #B	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	"NEW FIRE ALARM SYSTEM IN BUILDING ""B""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20442	12041-10000-03206	2039 E CESAR E CHAVEZ AVE	90033	14	129A223    73	5175029005	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM			PC Approved	02/10/2012 12:00:00 AM	ADDRESS	34.04886	-118.21202	TI in a retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20443	16041-20001-40686	6040 N CALVIN AVE	91356	3	177B117   584	2153035013	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.1803	-118.55544	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 400A split bus panel.20.16kW ungrounded system. (56) 360W ac modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20444	14041-20000-32534	14614 W DEERVALE PL	91403	4	162B149   458	2275022008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Expired	01/05/2017 12:00:00 AM	ADDRESS	34.1384	-118.45295	FEE CHARGE $0.00 BY STATE SENATE BILL NO. 122PV1. ROOFMOUNTED SOLAR SYSTEM. NEGATIVELY GROUNDED NON STANDARD PLAN. SYSTEM SIZE: 15.3 KW DC. (60) KYOCERA # KD255 GX(1) FRONIUS IG 11.4 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20445	16041-20000-24640	4803 N GLENALBYN DR	90065	1	148-5A223  45	5466030003	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Expired	09/08/2023 12:00:00 AM	ADDRESS	34.10313	-118.21134	Plan check for PV battery back up system in Single Family Dwelling 4kW battery connected to existing PV System. Note: Existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20446	17041-10000-02832	1245 W WILSHIRE BLVD STE 790	90017	1	132A207   288	5143017041	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	FULL PLAN CHECK FOR POWER AND ENERGY FOR FIRST GENERATION 1,746 SF MEDICAL OFFICE TI WITHIN EXISTING MEDICAL OFFICE BUILDING. CORE AND SHELL SPACE.PROJECT USES EXISTING  SERICE AND PANELS WITH 1 NEW PANEL IS BEING INSTALLED. BUILDING APP #17016-10000-01879	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20447	19041-10000-14758	1668 W SEPULVEDA BLVD	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Info Complete	09/13/2019 12:00:00 AM	ADDRESS	33.81659	-118.30843	INSTALLING NEW OUTDOOR LIGHTING. T-24 ENERGY ONLY. TOTAL AREA: 30,428SQR FT.THE PANELS AND 1,000 AMP SERVICE ARE EXISTING TO REMAIN.REF# 19041-10000-14747	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20448	14041-20001-17966	7369 W CHANTILLY CT	91042	7	210B197   534	2552048021	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM			PC Approved	07/31/2014 12:00:00 AM	ADDRESS	34.2727	-118.29345	Fee is 0.00 base on Senate bill 1222 from 2012Contractor  was sent back to plan check for detail display of the (13) modules on a string and the lengh of wiring on the plan; contractor  also changed a breaker to standard size of 15Amp.(((PV1Install roof mounted solar array on SFD. System size: 4.3kW(20) EnPhase M215 microinverters(20) SW 270 Mono pv modules)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20449	18041-10000-47222	802 S PIER A ST BERTH 154--155	90744	15	024B205    48	7440019907	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.75729	-118.27049	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20450	14041-20000-16616	131 E 6TH ST	90013	14	127-5A211  48	5148020007	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	PIN	34.0448716	-118.24914723	TI to (E) commercial bar on grade level of (E) mixed-use highrise building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20451	13041-20000-24968	2031 S BUTLER AVE	90025	11	126B149  1088	4261036008	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.03843	-118.44605	PV1 MICROINVERTER. TOTAL SYSTEM SIZE 2.12KWDC. 8 PANELS AND 8 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20452	12041-20000-12204	15301 W VENTURA BLVD	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM			PC Approved	05/29/2012 12:00:00 AM	ADDRESS	34.15411	-118.46654	energy plan check amazon.com 3rd floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20453	13041-10000-27127	9960 N HAYVENHURST AVE	91343	12	204B137   987	2678026018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.25188	-118.49347	PV1.  Install 7 kW DC roof-moutned solar array, interconnect with main service panel.  1 transformerless inverter: Power-One Aurora PVI-6000-OUTD-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20454	12041-20000-06939	700 W STATE DR	90007	8	118-5A201 122	5037028908	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.01636	-118.28401	Plan check for signage, (2) internally illuminated signs for 'Taco Bell'.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20455	14041-20000-28019	1050 W CHILDS WAY	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.02262	-118.29103	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING LIGHT FIXURE TO BIOLOGY LAB FREEZER CLOSET USING EXISTING POWER EXUIPMENT.  120SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20456	18041-20000-38833	6080 W CENTER DR 1st Floor-Rest Rooms	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	33.97713	-118.39172	Plan check for Title 24 only in restroom 1st Floor Total area: 588 sq ft. B#18016-10000-27615	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20457	16041-20001-38743	882 S CRENSHAW BLVD	90005	4	132B189   777	5092002037	R3-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			11/01/2016 12:00:00 AM			PC Approved	11/05/2016 12:00:00 AM	ADDRESS	34.0569	-118.32157	RSES expedited plan check fee per applicant request.  PV2.  Install 7.2 kW roof mounted grid-tied PV system.  (24) modules with (1) 6kW rated central inverter with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20458	10041-20000-05345	14530 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM			Corrections Issued	04/13/2010 12:00:00 AM	ADDRESS	34.23519	-118.44861	TENANT IMPROVEMENT DD'S DISCOUNT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20459	10041-20000-18927	5955 N LINDLEY AVE	91356	3	177B125   762	2157013144	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.17874	-118.52748	Rebuild burnED church (PHASE 1).  New service, panels, branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20460	13041-20000-12414	9648 N COZYCROFT AVE	91311	12	201B109   242	2748003088	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.24574	-118.58185	Change to receptacles and lighting in an Existing office space.  Load is less than 200 amps per applicant.  PLAN CHECK ONLY for Energy, NO EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20461	15041-10000-27110	12452 W OSPREY LANE Unit #3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	PV2 installed roof mounted pv system  for UNIT #3. Size 3KW, interconnected with the main service panel.(8)modules: SPR-230NE-BLK-D(1)PVI 3.0-OUTD-S-US inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20462	13041-10000-27132	738 1/2 E BROOKS AVE	90291	11	111B145  1292	4239013027	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	33.99733	-118.46493	PV1.  Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel.  1 transformerless inverter: Power-One PVI-3.0-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20463	16041-10000-12510	1177 E 21ST ST	90011	9	120A211   109	5131009036	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.02365	-118.25347	PV1 rooftop solar installation on Duplex SFD, 2.15 kW AC.     (12) MODULES-Hyundai HiS-M250MG      (12)MICROINVERTERS-ENPHASE M215-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20464	19041-10000-52620	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	R3-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.04443	-118.29612	"Plan Check for fire alarm system, scope includes 1 fire alarm panel, 1 control panel, 35 devices**********TEMPORARY STRUCTURE FOR LESS THAN 180 DAYS FROM DATE OF ISSUANCE PER CODE SECTION 3103 ""TEMPORARY STRUCTURES"" FOR PRIVATE HIGH SCHOOL, MULTIPURPOSE ASSEMBLY USE  STRUCTURE IN CONJUNCTION WITH ZA-2003-6886-CU-ZV-SPR-PA1. PERMIT EXPIRES ON 06/11/2020."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20465	16041-20000-22745	9301 N TAMPA AVE UNIT 36	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HOLLISTER CO IN NORTHRIDE FASHION CENTER. 5765 SQFT. UNIT 36.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20466	12041-10000-03380	1806 W SUNSET BLVD	90026	13	139-5A209 106	5404016006	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	03/07/2012 12:00:00 AM	ADDRESS	34.07757	-118.25976	Rewire, new lighting for an existing office space.  This space has NO Emergency lighting, per the applicant.  No Suite number, stand alone building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20467	18041-20001-38501	5139 N DENSMORE AVE	91436	5	171B141   258	2261015036	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Issued	12/10/2018 12:00:00 AM	ADDRESS	34.16317	-118.47782	12/10/2018 Changes to an approved set of plans. All changes have been clouded. PV interconnection has been changed.*****Original Work Description*****PV1.  Install 14.3 kW roof mounted grid tied PV system.  (44) modules with 10 and 5 kW rated string inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20468	16041-30000-21241	801 S FIGUEROA ST	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the 17th floor restrooms of an existing commercial building. Project scope is a restroom improvement. Total lighting area = 640 sq. ft.Note: Building application has been generated under 16016-10000-11686	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20469	17041-20000-08893	19867 W PRAIRIE ST 2nd Floor	91311	12	198B113   114	2761040022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.23927	-118.56657	TI to (E) 2nd-floor office tenant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20470	12041-10000-27833	2210 W MARICOPA DR	90065	14	151-5A219 124	5462026039	RE40-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	34.1104	-118.22397	PV1 8.424KW ROOF-MOUNT ENPHASE MICROINVERTER - microinverter standard plan	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20471	19041-20000-05594	9901 W WASHINGTON BLVD 1ST FLR &-6TH FLR	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM			Corrections Issued	02/15/2019 12:00:00 AM	ADDRESS	34.02174	-118.39786	TI to ground floor lounge and 6th story outdoor patio.  Plan check for energy.  Building permit under 18016-30000-20933	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20472	14041-10000-29996	616 S NORMANDIE AVE	90005	10	135B197  1114	5502031011	R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			10/29/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.06287	-118.30017	Improvements to 16 story senior living apartment building.  Plan check for the addition of generator for fire pump and new lighting and power for redesigned 1st floor. Renovations to lighting for common area corridors above first floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20473	13041-10000-36220	710 N FRONT ST	90731	15	021B201   243	7440025904	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro, Wilmington		9800.31	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	06/24/2015 12:00:00 AM		Issued	06/24/2015 12:00:00 AM	ADDRESS	33.7518	-118.28623	NEW TWO STORY OFFICE BUILDING.BRETH 100-102 MARINE OPERATION BUILDING.  INSTALL NEW PANELS, MOTORS, TRANSFORMER, AND LIGHTING.  PLAN CHECK FOR POWER AND ENERGY.    (INDOOR AREA 3216 SF, OUTDOOR AREA 2490 SF)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20474	15041-20000-38941	10250 W SANTA MONICA BLVD # 9022	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	TI on an (E) coffee bean, PC for Energy and adding new branch circuits, total area: 321 sq.ft(((BL: TENANT IMPROVEMENT:  COFFEE BEAN IN EXISTING SHOPPING CENTER (327 S.F.).  PRE-PACKAGE FOOD ONLY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20475	12041-20000-14164	344 S LA BREA AVE	90036	4	135B181   309	5507008018	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	34.06756	-118.34382	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20476	18041-20000-39345	10610 W ROCHESTER AVE	90024	5	132B153   433	4326015002	R1-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.05839	-118.43286	Plan check for the addition of (1) Tesla PowerWall onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20477	17041-10000-30129	4134 S CRENSHAW BLVD	90008	10	114B185   522	5024009030	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Info Complete	10/19/2017 12:00:00 AM	PIN	34.00863572	-118.33477073	PC FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS, LIGHTS, EQUIPMENT AND RECEPTACLES. TOTAL AFFECTED AREA 1350 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20478	13041-10000-03576	2065 W 29TH PL	90018	10	120B193   124	5053004013	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.02835	-118.31083	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.085KW. USING 36 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20479	12041-10000-22394	6303 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		2077.10	Electrical	Electrical	Apartment			09/20/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI IN AN EXISTING OFFICE. EPC IS FOR T24. (10th FLOOR #1092)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20480	14041-10000-31412	17122 W ARMSTEAD ST	91344	12	213B133   261	2607016025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.28263	-118.50543	Plan check for a residential roof-mounted PV system. System size is 6 kWac. System consists of (29) modules, and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20481	18041-10000-03632	231 N BELLINO DR	90272	11	126B117   225	4416026018	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.04285	-118.56047	PV 1 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER WITH POWER OPTIMIZERS. TOTAL SYSTEM SIZE IS 5KWAC. (20) MODULES WITH OPTIMIZERS AND (1) 5KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20482	16041-10000-00699	2100 W WASHINGTON BLVD	90018	10	126B193   938	5074033016	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.03975	-118.30604	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (ICE CREAM SHOP). SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 898 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20483	15041-10000-33220	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	33.98489	-118.42552	TI TO AN EXISTING COMMERCIAL BUILDING (2) FLOORS.  INSTALL NEW UPS SYSTEM  NEWLY CONNECTED > 400 AMPS. ADDING NEW DISTRIBUTION BOARDS, PANELS, CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20484	13041-20000-11404	19731 W VANOWEN ST	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	05/02/2013 12:00:00 AM	ADDRESS	34.19397	-118.56313	T24 FOR EXISTING ONE STORY RETAIL BUILDING. SCOPE OF WORK FOR OUTDOOR CANOPY. 7850 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20485	17041-20001-21186	20417 W ELKWOOD ST	91306	3	189B113   948	2107013045	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.21245	-118.57776	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.10kW ungrounded system. (33) 330W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20486	12041-10000-13510	1875 S CENTURY PARK EAST #2240-#2250	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/11/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	ADDRESS	34.06115	-118.41457	T.I. to an existing office space.  A partition wall will be constructed to create two separate suites on the 22nd floor of a high-rise building.  Load is less than 400A , PLAN CHECK ONLY for Energy, with Emergency  lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20487	18041-20002-15986	8531 N FALLBROOK AVE 1st & 2nd-Floor	91304	12	192B097   582	2005022001	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.22425	-118.62931	10/26/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 8. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 forms.09-28-2018 Changes to approved set of plans - changes include lighting revisions and Title 24 calculations, site plan updates, single line revisions.  All changes have been clouded as delta 6.*****Previous Work Description*****Plan check for power and energy. Project site is the 1st and 2nd floor of an existing commercial building. Project scope is a tenant improvement. Work includes new distribution equipment and a total lighting area of 99,075 sq. ft.Note: Building application has been generated under 18016-10000-13438	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20488	13041-10000-34124	4433 S ALAMEDA ST BLDG A, AA	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.00295	-118.23924	PLAN CHECK FOR  EMERGENCY LIGHTING AND EXIT SIGNS ONLY PER INSPECTORS REQUEST.  1 OF 5 BULDINGS. BUILDING A & BUILDING AA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20489	17041-20000-07313	515 S FLOWER ST 23rd flr	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	ti to an exisrting commercial building (high rise) 23rd floor.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 13213.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20490	11041-20000-15061	300 S GRAND AVE FLR  25	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	PIN	34.05243427	-118.25124731	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR OFFICE TI ON 25TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20491	16041-20000-06715	4151 W PROSPECT AVE STAGE 2	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Demolition of (E) distribution equipment.  New distribution equipment, ATS, and 150 kVA transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20492	17041-20000-32193	5337 N BAZA AVE	91364	3	171B105   216	2168024056	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Expired	04/14/2024 12:00:00 AM	ADDRESS	34.16683	-118.60093	Plan check for solar pv system, roof-mounted on SFD.5kW ungrounded system. (20) 290W pv modules.Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20493	11041-10000-24890	500 W WORLD WAY Terminal 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check power only for concession stand upgrade for LAX Terminal 5. Concession stands future.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20494	16041-10002-13870	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	"12/06/16Changes to an approved set of plans. All changes are clouded under delta 6, 7, and 8. Changes include removing load on panelboards, relocating circuits/lights, revising single line diagram, adding a new circuit breaker for new tenant 112 on distribution board ""TMSFA"", revising feeder schedule, and revising floor plans."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20495	14041-10000-18352	18618 W LOS ALIMOS ST	91326	12	207B121   331	2717018013	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.26531	-118.53888	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER STANDARD PLAN. SYSTEM SIZE: 7.3KW AC.(34) LG265 MODULES(34) ENPHASE M215 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20496	17041-10000-11922	1301 W COLTON ST	90026	1	135A209   296	5160019006	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			04/12/2017 12:00:00 AM			PC Info Complete	04/06/2018 12:00:00 AM	ADDRESS	34.06308	-118.25665	FULL PC. FOR A NEW 29 UNITS, 4 STORY, OVER TWO SUBTRANIAN LEVEL APARTMENT BUILDING. 1200 A SERVICE,  AFFECTED T24 AREA  31795 SQ FT.B# 16010-10000-04310	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20497	14041-10001-19839	500 WORLD WAY 4thFloor	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	Changes to approved set.  Full plan check revised by adding one 24KW water heater and  one 70-Amp  panel.  All changes clouded and marked with delta-4 only.*****Previous Work Description*****plan check for power and energy. 4th floor. Delta airline Terminal 5 SKYCLUB Renovations. Changes include clarifications on T24 and 100% rated breakers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20498	13041-20000-30086	3719 S COLONIAL AVE PV1	90066	11	114B153  1198	4246023008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.00553	-118.43635	New Enphase microinverter PV rooftop PV system for an existing single family dwelling.  Plan check/Permit is for PV System only, Not for Main Service Upgrade.  ((TRUNK CABLE NOT TO EXCEED 51'))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20499	19041-10001-33007	2155 N MOUNT OLYMPUS DR	90046	4	151-5A175   9	5569026018	RE40-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.11151	-118.3688	Expedite FeesPV1, new rooftop mounted system, system size is roughy 70.83 KWdc/56.8KWac. Scope of work is 196 modules (Longi Green Energy LR6-72VH-340M) with micro inverters (Iq7Plus-72-2-us), leading to a PV subpanel (800A), terminanting in a exisitng 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20500	14041-20000-04230	10115 W RIVERSIDE DR	91602	4	165B181    35	2424008013	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.15237	-118.35118	PLAN CHECK FOR T24 PART 6 ENERGY ONLY for juice bar; SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING WORK IS APPROX. 492 SF. plan check AND permit will be under this application.bldg permit under: 13016-20000-15198	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20501	17041-10001-12133	15005 W NORTHWIND LANE	91343	7	198B145   463	2651001***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.23893	-118.45907	PC FOR CHANGES TO APPROVED SET. CHANGE TO LAYOUT AND PERMIT FOR DERATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20502	14041-10000-35544	425 S PALOS VERDES ST	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			Reviewed by Supervisor	01/09/2015 12:00:00 AM	ADDRESS	33.74102	-118.28156	possible CRA clearance required if doing work outdoors. VFD cutsheets can be provided: see email provided. 5 branch circuits for VAV 120/24V low votlage circuits to be added to fees.plan check for power only. REPLACING (E) HVAC MOTORS AND RECONNECTING BACK WITH VFDS. on Port of LA office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20503	13041-20000-33807	3887 S DEGNAN BLVD	90008	10	117B185   966	5033012024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.01494	-118.33014	New rooftop PV system for an existing sfr.  System is UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20504	17041-20000-43274	229 N BURLINGTON AVE	90026	13	136-5A207 286	5159006009	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	05/08/2020 12:00:00 AM		Permit Finaled	01/05/2021 12:00:00 AM	ADDRESS	34.06717	-118.26626	600A 240/120V 1ph-3w service, distribution, power and lighting for small lot subdivision.  Individual dwelling unit wiring and subpanel permits under individual building combination permits for SFDs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20505	18041-10001-44613	5524 N WILBUR AVE	91356	3	174B121   527	2161003002	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM			Corrections Issued	12/20/2018 12:00:00 AM	ADDRESS	34.17155	-118.54459	**FEE EXPEDITED PER APPLICANT**NEW PV-2 (SOLAR SYSTEM ON COMMERCIAL BUILDING). SYSTEM SIZE 190.575 kW (DC-STC) / 150 kW AC ON  3 STEEL SOLAR CARPORTS, SYSTEM CONSIST OF (495) MODULES, (3) 50 kW INVERTERS, (1) 225 kVA STEPDOWN TRANSFORMERB# 18010-10000-05616	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20506	11041-10000-03498	2625 E CESAR E CHAVEZ AVE	90033	14	127-5A225  16	5177033029	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2037.20, 2042.00	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	02/12/2013 12:00:00 AM	ADDRESS	34.04547	-118.20441	TI IN AN EXISTING RETAIL STORE.  PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20507	16041-20000-40359	18813 W VANOWEN ST	91335	3	183B121  1069	2126027015	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.19399	-118.54316	PV1.  Install 12.1 kW DC roof-mounted grid-tied PV system.  (27) modules with (2) transformerless central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20508	19041-10000-27499	11546 W SHERMAN WAY	91605	2	183B169   691	2320001041	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.20097	-118.38407	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20509	15041-10001-33243	475 N CONCORD ST	90063	14	127-5A229 100	5178024040	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2038.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.04295	-118.19367	Supplemental PC only per inspector.  (13) SPR-327-NE-WHT, (1) SB3800TL No new equipment. Permit under 15041-90000-33243. <<Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20510	17041-10000-09160	1286 W 36TH ST APT #1	90007	8	120B197   964	5040007019	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			03/22/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.02268	-118.29705	PV2. NEW SOLAR SYTEM ON AN EXISTING MULTI-FAMILY HOUSE (ROOF-TOP). TOTAL SYSTEM SIZE IS 3.92KWdc / 3.50KWac.(14)MODULES-HANWHA Q-CELL Q.PLUS BFR-G4(14)MICROINVERTERS-ENPHASE M250-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20511	14041-10000-17516	2029 S CENTURY PARK EAST 21ST, 22ND	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Corrections Issued	07/03/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	TITLE 24 AND EMERGENCY LIGHTING FOR A HIGH RISE. 10TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20512	15041-20000-01017	3113 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.02998	-118.37407	T.I. to existing building.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy. new lighitng for new mezzanine. this building still under contruction since 2008. pc in accordance to 2008 building efficiency standards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20513	18041-10001-19855	6260 W SANTA MONICA BLVD	90038	13	144B189   702	5534022031	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			PC Approved	04/05/2019 12:00:00 AM	ADDRESS	34.09056	-118.32632	SUPPLEMENTAL CHANGES TO APPROVED SET. CHANGES APPLIES TO CLOUDED DELTA 6 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20514	17041-10000-43198	3425 E WHITTIER BLVD	90023	14	121-5A227 112	5188004042	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.02751	-118.2	REPLACE OUTDOOR AND INDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 52450 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20515	17041-10000-45297	1001 W KNOX ST	90502	15	057B197    18	7351031017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.85434	-118.29392	PC FOR POWER AND ENERGY FOR TI. SCOPE INCLUDES NEW PANELS, CIRCUITS AND LIGHTNG TO A MANIFACTURING SPACE.TOTAL CONNECTED AMPS OVER 400 AMPS.TOTAL AFEECTED AREA 22,901 AQ FT.B# 17016-10000-37441	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20516	15041-10003-30939	11455 W BURBANK BLVD BLDG A&B	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	CHANGES TO THE APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 14. CHANGES INCLUDE ADDING TWO NEW 2KW INVERTERS, 2 LIGHTING CONTROLS PANELS, REVISING SINGLE LINE DIAGRAM, REVISING FLOOR PLANS TO IDENTIFY EMERGENCY CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20517	19041-20001-29441	625 E COLEMAN AVE 1 of 2	90042	14	148-5A231   3	5301011029	[Q]RS-1D	East Los Angeles	Northeast Los Angeles	Hermon	YES	2013.02	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	09/05/2019 12:00:00 AM	ADDRESS	34.10231	-118.18265	expeditepv3install roof mounted pv system sized 21.4KW AC interconnecte with msp.this is system 1 of 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20518	16041-10000-33199	714 W OLYMPIC BLVD 8th fl	90015	14	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.04454	-118.26341	installing in the corridors on the 8th floor exit signs and emergency luminaires	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20519	18041-10000-05333	14743 W FRIAR ST	91411	6	180B149   957	2241002900	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.18581	-118.45458	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20520	18041-20000-07396	3976 W 6TH ST	90020	10	135B193   893	5503031008	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	ADDRESS	34.06338	-118.31004	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20521	12041-20000-20022	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.15886	-118.50032	New fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20522	16041-20000-16018	15037 W ROXFORD ST #9	91342	7	228B145   811	2502002***		North Valley				1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.32186	-118.4606	PV1INSTALL ROOF MOUNTED PV SYSTEM STANDARD PLAN.  SYSTEM SIZE 3.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20523	15041-20000-34774	12739 W VAN NUYS BLVD	91331	7	210B161    29	2533019032	[Q]C2-1VL-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.27542	-118.41112	Plan check for Title 24 only. Project site is an existing commercial building (Rite Aid). Project scope is a tenant improvement to the pharmacy located within the store. Total lighting area = 353 sq. ft.Note: Building application has been filed under 15016-20000-20559	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20524	17041-20001-32281	6344 W ARIZONA CIR	90045	11	105B165   656	4110014008	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	33.98055	-118.39751	Title 24 Part 6 energy only plan check for new commercial lighting in warehouse offices/support spaces.  Warehouse area lighting existing to remain.(((Add circuit,lights,receptacles switches,telephone)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20525	10041-20000-17729	8922 1/2 N RESEDA BLVD	91324	12	195B125   339	2769002005	C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	PIN	34.23260537	-118.53570343	Install a light in restroom area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20526	19041-10000-03026	14401 W FOOTHILL BLVD 1-37	91342	7	228B149   184	2502024020	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Apartment			01/25/2019 12:00:00 AM	06/08/2021 12:00:00 AM		Permit Finaled	07/14/2023 12:00:00 AM	ADDRESS	34.32122	-118.44777	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 37 UNITS APARTMENT BUILDING SCOPE OF WORK INCLUDES NEW 1600AMPS SERVICE,208/120 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 34808 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20527	19041-20001-00046	5670 W WILSHIRE BLVD 100	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	3/12/2019changes to an approved set of plans.  changes to lighting fixtures and energy calculations.  this is plan check only.  ((((Plan check for Title 24 only in existing space Interrior Remodel Total area: 7789 sq ft. B-18016-10000-41259))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20528	16041-20000-23320	21621 W HEATHERLEE LANE	91311	12	210B105    87	2722004036	RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.27053	-118.60058	Plan check for PV roof mounted system. System size: 10kW with 50 modules and 1 inverter(10.0kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20529	14041-10000-09757	8658 N NAGLE AVE	91402	6	195B157  1178	2627027034	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Closed	12/07/2015 12:00:00 AM	ADDRESS	34.22703	-118.42307	PV1 6.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(26)modules: {HYUNDAI HIS-M250-MG}] with optimizers: [SOLAREDGE {POWERBOX 250}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20530	13041-10000-28980	6921 S LA TIJERA BLVD	90045	11	102B173   156	4103003015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Expired	11/11/2015 12:00:00 AM	ADDRESS	33.97563	-118.37395	NEW FIRE ALARM SYSTEM INSTASLLATION WITH 41 DEVICES AND 1 PANEL FOR A VONS STORE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20531	11041-10000-14663	100 N LA CIENEGA BLVD	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.07466	-118.37629	FIRST TIME TENANT IMPROVEMENT IN MALL, POWER, LIGHTING, EMERGENCY AND TITLE 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20532	13041-10000-32749	1500 W PACIFIC COAST HWY BLDG C	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING CTHIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20533	17041-10000-35216	3825 S CRENSHAW BLVD Suite 101	90008	10	117B185   569	5045018038	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.01718	-118.33567	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMERICA BANK. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2638 SQ. FT. B#17016-10000-28763	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20534	11041-20000-09170	5523-5547 N ETHEL AVE	91401	5	174B161   520	2345005015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	09/19/2011 12:00:00 AM	ADDRESS	34.17078	-118.41824	PLAN T24 ENERGY FOR OUTDOOR LIGHTING FOR PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20535	12041-20000-04286	10250 W SANTA MONICA BLVD 138	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	Renovate existing retail tenant space.  Tailored method lighting forms.  Inpsector to verify listing and rating of integral currnet limiters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20536	13041-10000-30518	10309 W SANTA MONICA BLVD	90024	5	132B157   365	4327017017	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	PIN	34.05943838	-118.42195052	Remove HID light fixtures and replace with new fluorescent fixtures in a 2-story parking structure.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20537	15041-10000-40870	26332 S SENATOR AVE	90710	15	033B193   734	7411024050	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	33.7827	-118.30288	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNWECTED WITH MSP.(22 SOLAR WORLD SW250 MODULES(1) 5KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20538	13041-20001-35882	447 N FAIRFAX AVE	90048	5	141B177  1285	5527031018	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	PIN	34.07945639	-118.36178388	[[[2/12/15 SUPPLEMENTAL PLANCHECK FOR T24 UPON INSPECTOR'S REQUEST. ]]]T24 FOR EXISTING RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20539	19041-20000-51815	3851 S INGLEWOOD BLVD	90066	11	114B157  1446	4235027003	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Apartment			12/16/2019 12:00:00 AM	03/26/2021 12:00:00 AM		Permit Finaled	10/13/2023 12:00:00 AM	ADDRESS	34.00482	-118.42809	PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A NEW 600A (120/240V, 1 PHASE, 3 WIRE) SERVICE, (6) SUB-PANELS, BRANCH CIRCUITS, LIGHTING,  MOTORS,  AND ASSOCIATED LOADS. TOTAL AFFECTED AREA IS 5,770 SQAURE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20540	17041-10000-30036	1241 N ROSCOMARE ROAD	90077	5	144B145   107	4377019011	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.09227	-118.46266	NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.PC FOR PV SYSTEM USING S280 MICROINVERTER. USING TOTAL OF 76 MODULES AND 2 SOLAR LOAD CENTERS. TOTAL SYSTEM SIZE IS 24.32KWdc / 21.28KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20541	14041-10000-03159	12022 W RIALTO ST	91352	6	192B165   295	2633011005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.22421	-118.39429	PV1 3KWdc. 240V. microinverter. STD. 1story. Roofmount. [(12) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(12)modules: {Renesola {JC250M-24/BB}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20542	19041-20000-05394	2011 E ZONAL AVE 511-513	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 207 sq ft. B#19016-10000-00110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20543	18041-30000-01516	601 S FIGUEROA ST #3800	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing high-rise building T.I. office space. Total area:3750B#18016-10000-00846	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20544	14041-20000-10128	10501 N MONOGRAM AVE	91344	12	207B137   788	2679002035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.26133	-118.49261	Roof mounted PV system with Optimizer and transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20545	15041-10000-00397	9673 N TOPANGA CANYON PL	91311	12	201B101   419	2746016074	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.24586	-118.60511	Plan check T-24 only for retrofit existing light to LED with retorfit kits. Total area: 7947SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20546	17041-20000-00098	5555 N BONNER AVE	91601	2	174B173  1075	2350005006	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.17159	-118.37432	Plan check for power and energy. Project site is a new 4-story, 31-unit apartment building over (2) levels of basement parking garage. Total lighting area = 57,000 sq. ft.Note: Building permit has been pulled under 15010-10000-01067	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20547	17041-10000-34923	972 E 41ST ST	90011	9	115-5A209 365	5115023014	R2-1	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.0091	-118.25856	PC for rooftop for 15 modules and 3.8kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20548	16041-10001-26870	23397 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Issued	12/16/2016 12:00:00 AM	ADDRESS	34.15981	-118.6342	FULL PC FOR POWER AND ENERGY FOR (E) RESTAURANT WITH OUTDOOR DINING AREA. SCOPE INCLUDES NEW LIGHTS AND NEW RECEPTECLES. TOTAL AFFECTED AREA 4497 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20549	17041-10000-08781	1606 W SUNSET BLVD	90026	13	139-5A209 185	5404018002	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	10/24/2023 12:00:00 AM	ADDRESS	34.07672	-118.25775	CHANGE OF USE FROM JUICE BAR AND RETAIL TO MARKET AND RESTAURANT. OUTDOOR DINING AREA 4998SF. 800A SERVICE AND NEW ELECTRICAL WORK. BACK FEED 1 EXISTING SUBPANEL ND ASSOCIATED LOADS.  PC FOR POWER AND ENERGY. BUILDING PERMIT 16016-10000-18044	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20550	18041-10001-39208	7051 W WILLOUGHBY AVE	90038	4	144B181   804	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Info Complete	11/26/2019 12:00:00 AM	ADDRESS	34.08719	-118.34309	"Delta ""3"" & Delta ""6"" changes to approved plans. <<<Full plan check for a retail and restaurant T.I with (1) panel exceed  600-Amp. Scope include new lighting and equipmnt with a total area of 11,950-SQ FT.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20551	18041-20002-21308	820 W COLDEN AVE	90044	8	093A199   129	6054001009	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Apartment			08/30/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	33.94893	-118.29021	Revisions to approved set of plans.  Addition of 225A subpanel to subfeed 30 HP elevator and (1) tenant panel.  Revised common area lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20552	14041-10000-04663	4246 N RIVERTON AVE	91602	2	165B177   826	2423022027	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.14715	-118.36614	PV1, INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(16) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20553	17041-10000-39297	10250 W SANTA MONICA BLVD kiost#9188	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for a first time tenant, retail KIOST #9188 ""SAVE MY BAG"". Work includes new power and lighting."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20554	18041-20000-36923	1819 S MESA ST LOT 4	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	33.72752	-118.28593	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20555	18041-20001-38952	4316 N LANAI ROAD	91436	5	165B137   222	2284012028	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.14892	-118.49181	Expedite per applicant requestPlan check for PV roof mounted system on commercial building, System size: 199.75KW DC, 172KW AC with 655 modules and 4 inverters(43.2KW) Supply side connection to Exist 1600A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20556	14041-20000-03327	8412 S MAIN ST	90003	9	097-5A205 104	6030013003	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	33.96247	-118.27371	T24 FOR EXISTING RETAIL STORE. PERMIT HAS ALREADY BEEN PULLED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20557	17041-10000-46015	4328 W MELROSE AVE	90029	13	141B197   505	5538030019	C2-1	Central	Wilshire	East Hollywood		1926.10	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			Reviewed by Supervisor	01/16/2018 12:00:00 AM	ADDRESS	34.08344	-118.29506	Power plan check for an 800 amp service upgrade. Scope includes new service panel and (5) subpanels reconnecting to the existing load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20558	10041-10000-01201	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	07/26/2010 12:00:00 AM	ADDRESS	34.21302	-118.45859	Existing Target remodel - Permit is for the addition of new ckts, new equiopment, new panels, etc for market upgrade.  An additional hour fee for T-24 review was included.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20559	16041-10000-11468	982 S CATALINA ST	90006	10	129B197    90	5078007019	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.05324	-118.29462	Full PC for a newly constructed 13 unit apartment. Building is 6 stories plus a 2 level parking basement. New 1200 Amp service 120/240 3 phase 4 wire. 4 typical units (a,b,c,d) plus one unit in 6th floor). Total sq ft = 26,870.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20560	15041-10000-13376	837 N SPRING ST	90012	1	135A215   314	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	PIN	34.06296813	-118.23676788	NEW SPRINKLER MONITORING SYSTEM TO AN (E) 3 STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20561	17041-20000-20983	7816 N FALLBROOK AVE	91304	12	189B097   845	2013026018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Issued	06/21/2017 12:00:00 AM	ADDRESS	34.21246	-118.62316	Plan check for solar pv system, roof-mounted on SFD.5.2kW ungrounded system. (21) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20562	13041-10000-20342	1420 S FIGUEROA ST	90015	9	126A205   176	5134009019	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			07/31/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.03815	-118.26937	pc for power and energy.  METHANE Zone. PROPOSED  193 UNIT APARTMENT AND PARKING GARAGE. 7 STORY (5 LEVELS OF TYPE IIIA APARTMENT OVER 2 LEVELS OF TYPE I , APARTMENT AND PARKING OVER 2 LEVELS OF BASEMENT PARKING.[][][conduit variance filed and paid for on 10/11/2013 under 13041-10000-28450 . pl,10-11-13[][][	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20563	10041-20000-17874	10960 W WILSHIRE BLVD #920	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	12/28/2010 12:00:00 AM	ADDRESS	34.058	-118.44597	energy plan check # 920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20564	16041-10002-23506	1331 N FIGUEROA PL	90744	15	033B201    19	7412009010	[Q]R3-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Harbor City		2943.02	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	33.78929	-118.28357	12/12/2016 Changes to an approved set of plan. Changes include new string layout. Changes apply to delta D and E{{{{{{Permit fee is $0.00 due to Senate Bil: 1222PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 40.25KWac. SOLAR SYSTEM IS FOR BLDG 6 & 7.(147)MODULES(7)INVERTERS(1)200A PANEL}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20565	13041-20000-27231	970 W 190TH ST SUITE 470	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	33.85812	-118.29302	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. NEW LIGHTING. EXISTING EXIT SIGNS. TOTAL AREA 2196 SQ FT. PERMIT TO BE ISSUED UNDER THIS APPLICATION. WORK DONE IN SUITE 470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20566	17041-20000-30664	13063 W VENTURA BLVD	91604	2	165B161   932	2375020012	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.14601	-118.4181	Plan check for energy only. TI to (e) 2-story office building w/ basement. New lighting (incl. emergeny) - 5,610sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20567	14041-10001-07085	5938 W 75TH ST	90045	11	102B169   342	4104012019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	33.97302	-118.38725	EXPEDITED RSES PLAN CHEK PER APPLICANT REQUEST. {{PV1, INSTALL  A 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(24)MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20568	19041-10001-33580	2358 W COLORADO BLVD	90041	14	162A221    75	5686001007	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	34.13958	-118.21781	Plan check for lost set of plans. Note: PC only. Permit under PCIS#19041-10001-33580(((((Plan check for a PV1 6kW roofmounted system with (21) modules, (1) inverter and (1) existing PV system interconnecting through the load center. Total system size with new and  existing system size is 11.00KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20569	17041-10000-17707	2828 N GLENDALE BLVD	90039	4	151-5A207 127	5438019016	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.1082	-118.26347	INSTALL NEW FA SYSTEM IN COMM. BUILDING ( PRE-SCHOOL).16 DEVICES AND 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20570	11041-10000-00964	20301 W VENTURA BLVD SUITE #220	91367	3	174B113   515	2166033040	(Q)C4-1LD, (Q)P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	04/28/2011 12:00:00 AM	PIN	34.16986681	-118.57545146	NEW DENTAL OFFICE IN SUITE # 220. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20571	14041-20001-01972	11450 W OXNARD ST	91601	2	177B169   816	2338011024	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	PIN	34.17916804	-118.38083573	(((expedite fees)))pv1 single family dwelling. total system size 3.8 kw ac using transformerless inverter nonstandard plan with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20572	18041-20000-48783	11937 N RICASOLI WAY	91326	12	216B109   332	2701085013	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.28986	-118.58501	Plan check for a PV1 roof-mounted PV system. System size is 15.925 kWdc/14.3 kWac-CEC and consists of (2) inverters, (49) modules, (2) battery back-up units, and (2) load centers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20573	19041-10000-23458	1830 N BRONSON AVE 1-81	90028	13	150A191   264	5586028026	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			06/19/2019 12:00:00 AM			PC Approved	06/19/2019 12:00:00 AM	ADDRESS	34.10433	-118.31784	ENERGY PLAN CHECK FOR A UTILITY, EQUIPMENT AND LAUDARY ROOM T.I. SCOPE INLCUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 940-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20574	17041-10000-38973	4755 S ALLA ROAD	90292	11	105B157   549	4212007006	P-1, [Q]MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	33.9835	-118.43032	PC for power only, scope of work includes the addition of (3) 200Amp suppercharegers to an existing distribution board.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20575	17041-10000-25451	2718 N ST GEORGE ST	90027	4	150B201   469	5433024001	R2-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.10866	-118.27499	PLAN CHECK FOR T24 ONLY - SCOPE INCLUDES REPLACING EXISTING (5) HID FIXTURES WITH NEW LED FIXTURES - TOTAL AFFECTED AREA =5200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20576	11041-10000-20681	1064-1070 E ELKGROVE AVE BLDG 20	90291	11	111B145   308	4243001037	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.00232	-118.4592	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20577	15041-10000-40678	1703 N AVENUE 55	90042	14	157-5A227 403	5479009009	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.12395	-118.19769	PV1, INSTALL 4.4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(16) MODULES: DUNIVA OPT275-60-4-180 AND P300 SOLAREDGE OPTIMIZERS(1) INVERTER: SOLAR EDGE SE3800A-US(240)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20578	10041-10000-23064	440 S VERMONT AVE #104& 105	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	FISET TIME TENANT IN COMMERCIAL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20579	13041-10000-03312	16926 W ROSCOE BLVD	91406	6	192B133   262	2205002004	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.22105	-118.50191	TI FOR A STARBUCKS. EPC IS FOR T24. (Outdoor+Indoor, using Tailored methode)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20580	16041-30000-13895	2330 W RIPPLE ST	90039	13	150A211    79	5437032015	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.10672	-118.25294	TI TO AN EXISTING COMMERCIAL BUILDING (RESTROOM ONLY).  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 420.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20581	14041-20004-17764	13287 N RALSTON AVE	91342	7	225B141   172	2501002027	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.31289	-118.47324	PC FOR REVISED SET OF APPROVED PLANS. CHANGES CLOUDED DELTA 7. RELOCATION OF LOADS. REVISED SHORT CIRCUIT RATINGS AND FAULT CURRENT VALUES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20582	12041-20001-12780	1181 N VIRGIL AVE BLDG A	90029	13	145-5A201 239	5542026022	R2-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Apartment			02/26/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.09322	-118.28673	Changes to approved set of plans. Addition of 125A subpanel and re-routing of conductors. Please coordinate plan check with that of Building B (12041-20001-12772).Enphase photovoltaic system on the roof of apartment buildings.  Building A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20583	19041-10000-16397	3136 W 8TH ST	90005	10	132B197   471	5094015001	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.05759	-118.29571	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20584	14041-20000-23463	23059 W SCHOOLCRAFT ST	91307	12	183B097   496	2026013008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.19698	-118.62981	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING CENTRAL TRANSFORMERLESS INVERTER WITH STANDARD PLAN. USING POWER OPTIMIZERS. USING 29 MODULESFIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20585	13041-20000-26878	16208 W ADDISON ST	91436	5	171B137   400	2260014010	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2013 12:00:00 AM			Reviewed by Supervisor	10/16/2013 12:00:00 AM	ADDRESS	34.16179	-118.48619	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 8.3 KW AC USING ENPHASE MICROINVERTER NONSTANDARD PLAN. 3 STRINGS. 39 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20586	15041-10001-30449	3335 S FIGUEROA ST STE D	90007	9	120A203   503	5123009042	[Q]C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			Ready to Issue	11/17/2015 12:00:00 AM	ADDRESS	34.02224	-118.28008	suplemental to the original plan to correct address.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20587	11041-10000-26655	1250 N CAPRI DR	90049	11	129B133    73	4407014005	A1-1XL, R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM			PC Approved	12/16/2011 12:00:00 AM	PIN	34.04999474	-118.49995246	Change to lighting in the mens and womans locker rooms at a tennis club.  PLAN CHECK ONLY for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20588	14041-20000-08163	21031 W VENTURA BLVD 610	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	PIN	34.16717222	-118.59179488	PLANCHECK FOR T24 ENERGY. PLANCHECK ONLY. Tenant Improvement in Suite 610. EMERGENCY LIGHTING. PERMIT ALREADY PULLED UNDER 14041-90000-06314.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20589	11041-20000-24556	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	"T.I.  For medical offices.  Full plan check.  All circuits and panels are existing.  There are 15 circuits that have been ""modified""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20590	10041-10000-25153	662 N SEPULVEDA BLVD Office-Parking	90049	5	138B145    76	4368016009	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.07736	-118.4688	New 3 story office and parking building. EPC is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20591	15041-20001-07277	13411 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/26/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.15778	-118.4248	07-26-16 Changes to an approved set of plans. Changes include feeder conductor from Cooper Metal Clad to Aluminum SE Cable. Changes apply to delta 1 only. {{{{{{Service upgrade to existing apartment building.  New 600 A service and switchgear.  Subpanels are being replaced to accomidate increased (future) load.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20592	16041-20001-45297	14349 W VICTORY BLVD	91401	6	180B149   830	2237022022	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			PC Approved	02/10/2017 12:00:00 AM	ADDRESS	34.18685	-118.44607	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on commercial building. Interconnect with a 400A MSP. 10kW grounded system. (34) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20593	12041-20000-04730	8361 W 3RD ST # 520	90048	5	138B173   758	5511015017	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM			PC Approved	03/09/2012 12:00:00 AM	ADDRESS	34.07307	-118.3723	T24 and emergency lighting plan check for  remodel tenant space.(Express permit was previously issued under PCIS 12041-90000-03140)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20594	12041-10000-07960	2377 W PICO BLVD	90006	1	129B197  1054	5076018019	C2-1	Central	Wilshire	Pico Union		2134.02, 2211.10	Electrical	Electrical	Commercial			04/06/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Issued	05/09/2012 12:00:00 AM	ADDRESS	34.04741	-118.28876	Remodel of an existing laundromat.  Service and all panels are existing.  New loads and circuits 767A of load.  Plan check for Power and Energy requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20595	16041-20000-14644	16543-16545 W ARMINTA ST	91406	6	189B137    34	2205009041	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.21498	-118.49391	Install a roof-mounted solar array on a commercial building. Interconnect directly with LADWP = FEED-IN-TARIFF SYSTEM. System size: 60kW [(3) 20kW inverters]. Ungrounded system.(230) 260W pv modules.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20596	18041-10000-07478	101 N LARCHMONT BLVD	90004	4	138B189   974	5515019012	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Issued	03/30/2018 12:00:00 AM	ADDRESS	34.07317	-118.32382	PC for T24 only for replacement of indoor lighting to LED fixtures with LED driver for Chase bank. Egress lighting is not part of the scope. Total area Indoor  is 5605sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20597	14041-10000-13411	11764 W SHELDON ST	91352	6	198B169    33	2538003040	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.24241	-118.38919	T24, Remove HID light fixtures and replace with new fluorescent fixtures. Total area 16028 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20598	16041-10001-29029	580 S ALAMEDA ST	90013	14	126A215   317	5164009041	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.03894	-118.23818	PC FOR CHANGES TO APPRVOED SET OF PLANS. FLOOR PLAN LAYOUT CHANGE AND CHANGE IN LUMIARE TYPE. PC FOR T24 CHANGES ONLY CLOUDED DELTA 5. SOME MINOR POWR REVISON CLOUDED AS WELL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20599	14041-20000-14286	13900 W VENTURA BLVD	91423	4	165B153   578	2266017005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.14847	-118.43513	PC for T24. TI for pet store. energy only. new lighting. permit issued under this application. due to building submittal, energy compliance to 2008 efficiency standards	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20600	19041-10000-16903	1604 S LA BREA AVE	90019	10	126B181    25	5067005021	C2-2D-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.04541	-118.34538	PC ENERGY ONLY FOR  RESTURANT. AREA OF SCOPE IS 1595 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20601	19041-10000-34908	6329 N CLYBOURN AVE	91606	2	180B177   316	2412019021	(T)(Q)C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1231.03	Electrical	Electrical	Apartment			09/04/2019 12:00:00 AM	03/17/2021 12:00:00 AM		Permit Finaled	10/26/2023 12:00:00 AM	ADDRESS	34.18578	-118.36001	Full PC for power and energy. Scope includes new 3000A 120/208V 3 Phase 4 wire service/distribution board, new 40 HP Fire pump, and new circuits and lighting. Total affected area is 62401 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20602	15041-20001-09212	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.19603	-118.45077	01-29-2016 Change to approved set of plans. Changes include addition 4 fire alarm devices to fire alarm system. {{{{{{{New fire alarm system for a new 49-unit apartment building. scope includes (1) fire alarm panel, (1) annunciator panel, (3) power supplies, and (149) fire alarm devices.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20603	14041-10003-26098	7635 N SEPULVEDA BLVD	91406	6	186B145    74	2222013012	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM			PC Approved	01/12/2015 12:00:00 AM	PIN	34.20935369	-118.46682857	Change to approved set by adding and removing light fixture  to match up with the floor plan. Note. all changes are under delta 4 only.(((Plan check for power and energy. 2013 standards. renovation of a tool retail store. Service, Panels, and transformers are existing to remain. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20604	16041-10000-16354	9132 N SEPULVEDA BLVD	91343	7	198B145   337	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.2368	-118.46732	PC FOR T24 ENERGY ONLY. PC FOR LANDLORD PORTION OF MAKING VANILLA SHELL. FUTURE TI WORK UNDER SEPARATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20605	12041-20002-09704	11900 W COURTLEIGH DR	90066	11	111B161  1000	4233019020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			05/24/2013 12:00:00 AM			PC Info Complete	05/24/2013 12:00:00 AM	ADDRESS	33.99718	-118.41875	Addition of three circuits. LIghting is landscape only thus no T-24 energy.New 28 unit apartment building. Fire alarm variance was file. Plan check for power and energy, the building is 5 levels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20606	14041-10000-22730	7007 S ARIZONA AVE	90045	11	102B165   229	4110005010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	33.97676	-118.39611	Installation of roof mounted solar microinverter PV system.  Total output = 5.25 kWac.  Owner-builder will install system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20607	15041-10000-34200	1132 N GLENDALE BLVD	90026	13	139-5A207 131	5404016022	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.07702	-118.26071	TI TO AN EXISTING COMMERCIAL BUILDING.  ADING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 72.  SCOPE OF WORK NEW RESTROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20608	16041-20001-12841	5525 W WILSHIRE BLVD	90036	4	135B181   896	5508011027	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	05/20/2016 12:00:00 AM	ADDRESS	34.06249	-118.34902	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a Commercial building. Interconnect with a 400A service.System size: 48kW (4 - 12kW inverters). Ungrounded system. (175) 285W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20609	12041-10000-00832	19809 W PRAIRIE ST	91311	12	198B113   115	2761040023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Approved	01/12/2012 12:00:00 AM	ADDRESS	34.23925	-118.56529	Modification to outdoor lighting for an existing parking lot.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20610	14041-20000-35568	13457 W MONTAGUE ST	91331	6	198B157   763	2625020018	RS-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.23692	-118.42618	PV1. Install roof mounted PV system sized 10kW. Interconnected with main service pannel. (38) SW 250 modules(1) 10,000A inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20611	15041-20000-37430	5550 N BONNER AVE	91601	2	174B173  1076	2350005052	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			10/20/2016 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.17145	-118.37398	Plan check for power and energy. Project site is a new 5-story, 48-unit apartment building with (1) level of subterranean parking garage. Total lighting area = 40,475 sq. ft.Note: Building application has been created under 16010-10000-00385	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20612	17041-10000-06877	2223 W FARGO ST	90039	13	145-5A209 717	5422016030	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.09242	-118.25943	PC for outdoor title 24 only. Removing HID fixutres with new LED fixutres. Area: 12,675 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20613	15041-10000-06523	6232-6256 N TOPANGA CANYON BLVD BLDG C&D	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.18412	-118.60489	NEW FIRE ALARM SYSTEM IN BUILDING C,D ON WESTFIELD PLAZA. 200 DEVICES AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20614	18041-20000-21517	23122 W ERWIN ST	91367	3	177B097   280	2039009014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.18266	-118.63057	PLAN CHECK FOR BATTERY BACKUP SYSTEM WITH EXISTING PV SYSTEM. SYSTEM CONSISNT (2) POWERWALLS - 13.5KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20615	16041-10000-32818	7948 N VAN NUYS BLVD	91402	6	189B149   634	2212028020	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.21559	-118.44851	PC for energy only to an existing building. Change of use from shell of bank to a restaurant. Adding new lighting and power. Total sqft = 1800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20616	12041-10000-27496	857 N LA CIENEGA BLVD	90069	5	141B173    21	4337002047	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.08684	-118.37666	TI TO EXISTING RESTAURANT. PLAN CHECK FOR ENERGY. METHANE BUFFER ZONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20617	17041-30000-31981	1320 N BEVERLY GROVE PL	90210	5	147B157   423	4356021034	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.09635	-118.42605	Plan check for PV roof mounted system in SFD with 10KW system and 49 modules and 10KW inverter connected to 600A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20618	10041-10000-06037	320 W 15TH ST	90015	9	124-5A207  85	5134015025	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	34.03668	-118.26664	Provide new service entrance conductors to the existing 1200 ampere service from a new above ground 2000 ampere double pull section box  which also supplies the new 2000 ampere service equipment at  1513 S Grande Avenue.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20619	17041-20001-32193	5337 N BAZA AVE	91364	3	171B105   216	2168024056	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	ADDRESS	34.16683	-118.60093	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.5kW ungrounded system. (20) 290W pv modules.Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20620	13041-10002-30088	23424 W CALIFA ST	91367	3	174B093    29	2041004004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.17721	-118.63725	Expedited RSES plan check per applicant request.(((PV1, Install 10.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 43 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20621	16041-10001-06514	11401 W SANTA MONICA BLVD	90025	11	129B149   513	4261003009	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			11/15/2018 12:00:00 AM			PC Info Complete	12/03/2018 12:00:00 AM	ADDRESS	34.04602	-118.4512	DELTA 3 CHANGES TO APPROVED PLANS. REEDUCING THE SERVICE FROM 2000 TO 1600 AMP AND REDUCING LOADS. RESIDENTIAL UNITS ARE EXISTING TO REMAIN.<<<<PC FOR POWER AND ENERGY. NEW APARTMENT BUILDING WITH 6-STORY, 51 UNITS. TOTAL AREA 56000 SQ FT,>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20622	15041-20001-18839	19143 W VICTORY BLVD 1-13	91335	3	180B121   534	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	34.18674	-118.55078	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9KW DC.  35-CS6P255 MODULES  AND 2-SMA SB4000US. BUILDING  # 4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20623	15041-10000-12485	19850 S MAGELLAN DR	90502	15	057B197    56	7351034065	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	33.85035	-118.29277	$0 PERMIT FEE DUE TO SENATE BILL SB-1222PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 196KW INTERCONNECTED WITH MSP.(734) SUNPOWER SPR-E20-327 MODULES(7) CHINT CPS TRANSFORMERLESS INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20624	17041-20000-40539	16605 W DEVONSHIRE ST	91344	12	204B137   253	2684017026	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.25763	-118.49415	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR OFFICES. 1634 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20625	15041-10000-42873	12121 W BLUFF CREEK DR 2ND FLR	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	33.97874	-118.40463	T-24, TI ON AN (E) BUILDING CORRIDOR AND ELEVATOR LOBBY. SCOPE OF WORK INCLUDES NEW LIGHTING ON THE 2ND FLOOR CORRIDOR AND ELEVATOR LOBBIES ON THE WEST AND EAST WING. TOTAL SQ. FT. 2276.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20626	18041-10000-24133	354 E 51ST ST	90011	9	111A205   342	5109024006	RD1.5-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2293.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	33.9964	-118.26817	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20627	09041-10004-08577	8050-8054 W 3RD ST 2ND FLOOR	90048	5	138B177   752	5511028012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/26/2010 12:00:00 AM	04/26/2010 12:00:00 AM		Permit Finaled	05/18/2010 12:00:00 AM	ADDRESS	34.07194	-118.36552	INSTALLATION OF LUMINAIRES IN PROPOSED OFFICE SPACE WHICH HAS NOT BEEN OCCUPIED; FIRST TIME TENANT WILL BE RESPONSIBLE FOR THE BUILT-OUTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20628	15041-20001-28029	1119 N BEVERLY GLEN BLVD	90077	5	144B153    47	4371017001	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.09497	-118.44082	Expedited per applicant request.Plan check for a PV1 roof-mounted Pv system. System size 3.8 kWac and consists of (1) inverter, (17) modules, and (17) power optimizers. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20629	12041-10000-10933	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM			PC Approved	05/11/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLAN CHECK T24 ENERGY FOR NEW STARBUCKS ON GROUND FLOOR. NO SEATING, NO EMERGENCY LIGHTING IN SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20630	17041-10000-24945	22346 W JAMES ALAN CIR	91311	12	204B101    88	2723008***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.25871	-118.61254	PC FOR PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING CENTRAL INVERTER WITH POWER OPTIMIZERS. USING 16 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20631	11041-10000-19643	3620 S MCCLINTOCK AVE Suite #716	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	34.0213	-118.28935	TI IN AN EXISTING COMMERCIAL AREA ON THE 7TH FLOOR IN SUITE #716.   PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20632	09041-10003-15447	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM			PC Approved	09/08/2010 12:00:00 AM	ADDRESS	34.27548	-118.56626	Construction changes to permitted set of plans. Changes are clouded on each sheet and referenced delta is shown on the plans and outlined in a letter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20633	18041-10001-19931	6761 S ARLINGTON AVE	90043	8	102B189   869	4008017030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Issued	07/24/2018 12:00:00 AM	ADDRESS	33.97655	-118.31885	PC FOR ESS SYSEM INSTALLATION SCOPE INCLUDES NEW POWER WALL2.0 WITH NEW LOAD CENTERPC FOR ROOF MOUNTED PV ON SFD WITH ESS (ON SEPERATE PERMIT). SCOPE INCLUEDS 10 MOUDULES WITH CENTRAL INVERTER. TOTAL SYSTEM SIZE 3.3KWAC/3.05KWDC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20634	14041-20000-30987	7508 N LEMP AVE	91605	2	186B169   451	2316012032	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Expired	12/01/2016 12:00:00 AM	ADDRESS	34.20688	-118.38436	pv1central string inverter standard plan system sized 5.0kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20635	14041-20000-29472	5209 N BUFFALO AVE	91423	4	171B157   607	2344016012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	PIN	34.1652068	-118.4304093	Roof mounted PV system with system size 6KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20636	15041-10000-40748	11700 N CORBIN AVE #97	91326	12	216B113     1	2701002068	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.28162	-118.57177	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7KW INTERCONNECTED WITH MSP.ZONING CLEARANCE FOR THIS APPLICATION SHALL COVER ALL MODEL HOMES(97,98,99) UNDER THIS ADDRESS.(TRACT 50509-01_ LOT 99) TWO STORY SFD WITH ATTACH 3 CAR GARAGE_ MODEL DWELLING*STANDARD PLAN # 643 _ PLAN 1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20637	19041-10000-33257	16930 W PARTHENIA ST	91343	12	195B133   470	2689018023	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.22833	-118.50167	Energy plan check for a new gym T.I . Scope includes new lighting and equipment with a total lighting area of 16,064-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20638	11041-10001-26788	2670 N GRIFFIN AVE	90031	1	139-5A223  15	5206010039	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.07841	-118.21167	Changing one 400 amp OCPD to two 200 amp OCPD.  Work is on pages E2 and E10.  PLAN CHECK ONLY.      <<<<<Tenant improvement on 3 story commercial bldg, lighting power, title 24, fire alarm under separate application.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20639	12041-10002-10032	6037 N TOPANGA CANYON BLVD	91367	3	177B101   126	2146025003	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.18032	-118.60616	"R3EVIONS TO THE LIGHTING SYSTEM OF PERMITTED SET OF PLANSAS-BUILT SET OF PLANS((((((CHANGE OF  USE FROM OFFICE TO REATIL  & ADD. ( 14'-8"" X 6'-0"": 88 S.F.) NEW ENTRANCE  &   TENANT IMPROVEMENTS TO AN (E) ( 9,430 S.F.) SINGLE STORY COMMERCIAL BUILDING & PARKING LOT RE-STRIPING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20640	15041-10000-19314	3410 W SAN FERNANDO ROAD #5	90065	13	153B209   115	5458003027	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.11875	-118.25083	T-24 ONLY, REMOVING HID LIGHT FIXTURES AND REPLACING WITH LED FIXTURES. (E) BUILDING AND WIRING. TOTAL SQ. FT. 6056.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20641	10041-20000-08780	865 S FIGUEROA ST 31st FL	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/12/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check T-24 Energy (general/emergency) lighting on 31st floor corridor/elevator area.  Existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20642	10041-10001-20750	2015 S SANTA FE AVE	90021	14	118-5A217  20	5167012036	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM			PC Approved	10/26/2010 12:00:00 AM	ADDRESS	34.02066	-118.2304	Revisions to lighting  system: relocate unit equipment and added 2 ea scones(((((((((T-24 lighting plan check for remodeled space.  Existing permit number 10041-10000-15080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20643	19041-10001-07248	333 S CHADBOURNE AVE	90049	11	129B137   269	4406024012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2019 12:00:00 AM			PC Approved	04/11/2019 12:00:00 AM	ADDRESS	34.05124	-118.49043	EXPEDITE PER APPLICANT REQUEST ((((((NEW ROOF MOUNTED PV SYSTEM WITH 729 PV TILES (TESLA SRT24) AND 3 CENTRAL INVERTERS(2 x DELTA SOLIVIA 5.2 & 1xDELTA SOLIVIA 3.8  )  ON A SINGLE FAMILY HOME. SYSTEM SIZE IS 17.3KWdc AND 14.2 KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20644	18041-10000-09965	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	34.12626	-118.21412	THE PROPOSED PROJECT CONSISTS OF  A canopy  for 343 SF  OUTDOOR STORAGE AREA AT THE BIOSCIENCE BUILDIng and alterations inside nearby locker/dressing roomPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20645	16041-10002-44955	9315-9317 W PICO BLVD	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.05542	-118.39328	Changes to an approved set of plans. Changes include replacing module type from canadian solar 340 W to SILFAB SLG345M. All changes are clouded under delta 2. The number of modules and roof-layout remains the same. NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-44955	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20646	15041-20000-28973	17074 W CALAHAN ST	91325	12	198B133   593	2692019032	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM			Reviewed by Supervisor	09/18/2015 12:00:00 AM	ADDRESS	34.2363	-118.50542	Plan check for PV roof mounted system. System size: 12.0kW with 44 modules  SUNPOWER 327 WATT and 2 inverters(6.0kW each)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20647	18041-20000-28161	300 S GLENROY AVE	90049	5	135B145    28	4366020006	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.07023	-118.46029	addition of (1) tesla battery energy storage device sized 14KWh to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20648	17041-10000-32642	6148 E MOUNT ANGELUS DR	90042	1	153A229   151	5484033026	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.1143	-118.18813	PC for new 3.8kW rooftop solar system. PC for new 14 rooftop modules with one SE3800H inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20649	16041-10000-16552	11912 W SHELDON ST FRONT	91352	6	198B169    80	2538002024	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.2401	-118.39236	PC for energy only to werehouse. Remove HID light fixures and replace with new LED fixtures. Total sqft = 41400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20650	16041-10000-41836	905 N WILCOX AVE #1-17	90038	13	144B185  1161	5533022011	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.08735	-118.33123	PC FOR POWER AND ENERGY FOR AN APARTMENT BUILDING.TOTAL OF 17 UNITS (1 TYPICAL).SERVICE SIZE AT 1200A 208/120 3PH.TOTAL AFFECTED AREA 48371 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20651	17041-10000-46591	1910 E 20TH ST	90058	14	118-5A215  83	5167006008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.0179	-118.2391	REPLACE INDOOR & OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20652	18041-30000-17423	19525-19535 W CARDIN PL	91324	12	198B117   258	2761035101	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.23767	-118.55883	POWER PLAN CHECK FOR A NEW 6 UNIT TOWNHOUSE BUILDING WITH ATTACHED GARAGES PER EACH UNIT. THE BUILDING IS LOCATED IN A SITE SURROUND WITH MULTIFPLE SIMILAR BUILDING. NOTE, OUTDOOR LIGHTING PLAN IS UNDER A SEPARATED APPLICATION #: 15041-20000-43922.Plan checker to verify outdoor lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20653	17041-10000-31132	12964 W PANAMA ST BLDG 4	90066	11	105B157   569	4223008010	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	33.9839	-118.42804	PC FOR POWER AND ENERGY FOR A NEW  4-STORY PARKING STRUCTURE (BUILDING 4). SCOPE INCLUDES NEW 1200A 277/480 DISTRIBUTION BOARD, SERVICE IS EXISTING UNDER SEPARATE PLAN/PERMIT.  NEW PANELS LIGHTS AND EQUIPMENT.   TOTAL AFFECTED AREA 167749 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20654	13041-20000-32445	530 N PALISADES DR	90272	11	129B117   107	4419015025	(Q)C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			Corrections Issued	11/20/2013 12:00:00 AM	ADDRESS	34.04525	-118.55178	PC FOR T24 ENERGY ONLY. EXISTING RETAIL/BANK. TOTAL AREA 1336 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20655	19041-20000-08232	7536 N LOMA VERDE AVE pv1	91303	3	186B109   352	2112001008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.20755	-118.58947	pv1install roof mounted pv system sized 3KW AC interconnected wtih msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20656	16041-10000-40522	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM			PC Info Complete	01/04/2017 12:00:00 AM	ADDRESS	34.21302	-118.45859	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 553.28KWdc / 390.0KWac.(1729)MODULES-JA JAP6 72-320/3BB(13)INVERTERS-SMA 30000TL-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20657	10041-20001-20934	16350 W VENTURA BLVD Unit C	91436	5	168B137   410	2284001055	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM			PC Approved	02/10/2011 12:00:00 AM	ADDRESS	34.15688	-118.48955	Plan check to revision approved plans. Revision is to reuse exisitng feeder supplying existing panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20658	12041-10000-07435	6600 N TOPANGA CANYON BLVD #1082E	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	TENANT IMPROVEMENT TO (E) RETAIL SPACE (2147 SF) new panelboard with new circuits ; new ahu;PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20659	19041-10000-24212	9705 S HOLMES AVE	90002	15	093A213   430	6048030041	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	33.94792	-118.24092	PC for T24 only, scope of work includes replacing lighting in four rehab rooms and a common bathroom. Total affected area is 893 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20660	13041-20000-17417	6255 W SUNSET BLVD 12th floor	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	Change to lighting in an existing high-rise office building.   Load is less than 400 amps per applicant.  Load greater than 400 amps will require Full Plan Check, subject to field inspection.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20661	16041-20000-33341	3731-3737 E OLYMPIC BLVD	90023	14	118-5A227 216	5191003021	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.01901	-118.19522	Plan check for power only. New 600A service and unit panels for existing commercial building. All interior circuitry and lighting to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20662	12041-20000-06819	7755 N HASKELL AVE	91406	6	189B141   232	2206011050	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00, 1274.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Issued	06/01/2012 12:00:00 AM	ADDRESS	34.21177	-118.47511	T.I. to a two story building.  Install new subpanels, and branch circuits, and lighting.  Plan for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20663	17041-30000-08407	22855 W VICTORY BLVD	91307	12	180B097   327	2038040021	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			Verifications in Progress	06/21/2017 12:00:00 AM	ADDRESS	34.18859	-118.62711	Plan check for a PV2 roof-mounted PV system. System size is 312 kWac and consists of (13) inverters, (1386) modules, and (5) distribution panelboards.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20664	17041-30000-10244	2828 N NEWELL ST Suite 1	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 921 sq. ft.Note: Building permit has been pulled under 17016-10000-02810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20665	12041-20000-01583	10341 W MAGNOLIA BLVD Gym room	91601	4	171B177   602	2417018030	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	02/17/2012 12:00:00 AM	ADDRESS	34.16506	-118.35633	t-24 LIGHTING PLAN CHECK ONLY FOR REMODELED GYM ROOM LOCATED ON THE 1ST FLOOR OF THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20666	16041-10000-40424	4553 S GLENCOE AVE #150	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	33.98415	-118.43328	TENANT IMPROVEMENT TO (E) OFFICE SPACE, PLAN CHECK FOR ENERGY ONLY. INSTALL NEW RECEPTACLES AND LIGHTINGS.  AFFECTED AREA 990 SQ.FTB# 16016-20000-21541	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20667	19041-10000-02075	5670 W VENICE BLVD	90019	10	126B177   479	5064015019	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.04325	-118.36186	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20668	15041-10000-06703	1149 S HILL ST 9TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	11/01/2021 12:00:00 AM	ADDRESS	34.03926	-118.26099	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGYAND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2256. SCOPE OF WORK IN THE 9TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20669	13041-10000-02545	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	TI OF 9TH LEVEL RETAIL SPACE. PC FOR POWER AND ENERGY. NEW CONNECTED LOAD > 400A. TOTAL AREA OF 14657 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20670	17041-10000-35333	5770 W HOLLYWOOD BLVD	90028	13	148-5A191 161	5586035001	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.10154	-118.3155	"T-24, PC FOR ENERGY ONLY. NEW LIGHTS FOR A 1 STORY PREFABRICATED METAL BUILDING AS AUTOMOBILE PARKING GARAGE. TOTAL AFFECTED AREA IS 600 SQ. FT. ""Comply with department order effective date 8/12/2014.  Permit wil expire 30 days from issuance date."" B#15010-10000-00093"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20671	17041-10000-45949	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Closed	08/23/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	PC FOR POWER ONLY. TEMPORARY POWER FOR A CONSTRUCTION SITE. SCOPE INCLUDES INSTALLING 1000KVA GENERATOR, 12000 480/277 3 PHASE  4 WIRE DISTRIBUTION BOARD, AND MOTOR EQUIPMENT. //INSPECTOR TO CHECK THAT TOWER CRANE IS LISTED FOR USE BY CITY OF LA RECOGNIZED TESTING AGENCY//	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20672	14041-20000-26332	751 S BURLINGAME AVE	90049	11	126B141   231	4264007009	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			09/24/2014 12:00:00 AM			Reviewed by Supervisor	10/31/2014 12:00:00 AM	ADDRESS	34.04291	-118.48237	NEW 6 UNIT/4 STORY (TYPE 111A) APT. OVER TYPE IA SUBT. PARKING GARAGEFIRE ALARM VARIANCE HAS BEEN FILEDPC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20673	13041-10001-02649	3802 W REVERE AVE	90039	13	156A207   176	5435008001	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.12238	-118.26101	Changes to approved set.  Modules REC 245 PE BLK changed to REC 250 PE BLK.  PHOTOVOLTAIC SYSTEM FOR SINGLE STORY SINGLE FAMILY DWELLING. PV1 SYSTEM TOTAL SIZE 2.16 KW. 10 UNITS. ENPHASE M215 MICROINVERTER. M215-60-2LL-S22. SOLAR PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20674	15041-20000-13828	5160 N VINELAND AVE 101C	91601	2	171B173  1378	2419001042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.16418	-118.37009	Plan check for power and energy. Project site is a hearing aid office. Project scope includes power and lighting. Total lighting area = 1,050 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20675	13041-10000-28641	9819 N GLENOAKS BLVD	91352	6	201B169    68	2537022027	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.2482	-118.38615	Remove HID light fixtures and replace w/ fluorescent fixtures.  Title 24 plan check only, permit to be issued at EPC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20676	17041-10000-42236	14929 W CHATSWORTH ST	91345	7	207B149   384	2648003017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.26464	-118.45732	PC for new rooftop solar for 7.6kW system (10.05kW DC). Installing 30 modules with optimizer and solaredge 7.6kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20677	12041-20000-02174	1501 N SAN PABLO ST S.423	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			01/30/2012 12:00:00 AM			PC Approved	01/30/2012 12:00:00 AM	ADDRESS	34.06263	-118.20329	S.423 T.I.ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20678	15041-10001-24484	9410 N BALCOM AVE	91325	12	198B129   105	2766002027	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	34.24153	-118.52147	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1 INSTALL 13.6 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(59) MODULES:  REC SOLAR REC275TP(2) INVERTERS: SOLAREDGE SE6000 AND SE 7600A-US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20679	14041-10000-18841	21940 W VENTURA BLVD	91364	3	171B101   170	2169003001	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.16827	-118.60527	"PLANCHECK FOR POWER AND ENERGY.  REPLACING EXISTING DISPENSOR , TURBANS WITH NEWER MODEL AT THE GAS STATION.  INDOOR AND OUTDOOR LIGHTING. HAZARDOUS LOCATION.BUILDING P # 140161000013701  DEMO & REBUILT T.I. AT EXISTING BLDG. INCLUDES FOUNDATION, STRUCTURAL, ADA PATH OF TRAVEL & PARKING, (2) RESTROOMS""COMPLY WITH DEPARTMENT ORDER effective date02/19/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20680	16041-10000-03320	9415 W OAKMORE ROAD	90035	5	129B165   726	4306025030	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Expired	02/28/2018 12:00:00 AM	ADDRESS	34.0479	-118.3937	PV1, NEW 4.2KW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(21) MODULES: TRIEX U290 BLACK(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20681	17041-30000-33846	423 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	33.77401	-118.27891	Plan check for Title 24 only in existing space wearhouse and office T.I. Total area: 9,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20682	19041-10000-03264	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	New FA system for a (N) warehouse building,  (1) FACP, (2) Power Supply, (160) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20683	15041-10000-38350	5253 N VANTAGE AVE 1-18	91607	2	171B165   358	2347020001	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.16639	-118.3984	FIRE ALARM SYSTEM FOR 18 UNIT APARTMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20684	16041-10000-02005	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Info Complete	01/20/2016 12:00:00 AM	ADDRESS	34.10222	-118.32701	ROOFTOP IMPROVEMENTS TO EXISTING HOTEL TO ADD ACCESSORY USES INCLUDING HOTEL ACCESSORY RESTAURANT/BAR. PC FOR ENERGY ONLY, 10,328 SQ. FT. (INDOOR+OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20685	11041-10001-20866	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	33.94386	-118.4047	CHANGES TO PERMITTED SET OF PLANS- RELOCATE,TRMOVE AND ADDED FA DEVICESnew fire alarm system for LAX. 266 devices and 5 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20686	11041-20000-21275	7217 N RESEDA BLVD	91335	3	183B125    78	2118029025	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Approved	11/03/2011 12:00:00 AM	ADDRESS	34.20172	-118.53623	Plan check only. Optometrist medical office.  Plan check is for power and energy. Permit under #11041-20000-13682	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20687	17041-10001-02794	101 S THE GROVE DR	90036	4	138B177  1131	5512003038	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM			PC Approved	05/24/2017 12:00:00 AM	ADDRESS	34.07256	-118.35874	PC FOR TITLE-24 ENERGY ONLY FOR A BAR TI IN THE GROVE.TOTAL AFFECTED AREA 391 SQ.FT.PLAN CHECK ONLY!PERMIT PULLED UNDER 17041-10000-02794	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20688	18041-20000-10171	9210 N ENCINO AVE	91325	12	198B129   312	2766011007	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.23819	-118.51548	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17.875 KW. LINE SIDE TAP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20689	10041-20000-18468	7564-7566 W MELROSE AVE	90036	5	141B177   651	5526016025	C4-1XL-O	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	05/25/2011 12:00:00 AM		Permit Finaled	11/23/2011 12:00:00 AM	PIN	34.083407	-118.35485229	Install new 600 amp service, panels, branch circuits, and lighting for a retail space.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20690	16041-20000-33295	7301 N QUARTZ AVE	91306	3	186B117   864	2115010018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.20309	-118.56466	Plan check for installation of pv system, roof-mounted solar on SFD. Interconnect with 200A MSP. Derating main to 175A. There is an exisitng 5kW pv system on SFD. New system is 3kW, ungrounded; (10) 315W pv modules; each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20691	17041-10000-46221	9320 N MASON AVE	91311	12	198B109    87	2748022056	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.24018	-118.5796	PC FOR POWER AND ENERGY FOR T.I for hydroponic agricultral enterprise.SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTING. TOTAL AFFECTED AREA 9332 SQ.FT. B#17016-30000-37853	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20692	11041-20000-22439	1449 N BEL AIR ROAD	90077	5	147B149   500	4370018023	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2011 12:00:00 AM			PC Info Complete	08/14/2012 12:00:00 AM	PIN	34.0966715	-118.44668019	PLAN CHECK NEW 2-STORY SINGLE FAMILY DWELLING WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20693	13041-10000-31650	671 S CORONADO ST	90057	1	133-5A201 157	5141008002	R4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.0598	-118.28202	FA IN (E) HISTORICAL BUILDING. (E) NOTIFICATION. NEW PANEL AND SLC (and operates elevator recall). Initiating device circuits: class B style B. signaling line circuits : Class B style 4. Notification appliance circuits: class B style Y.   R2 41 unit apartment building. building type III A. Existing Dorothy Mae compliant fire sprinkler.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20694	13041-20000-23758	7800 N CAPISTRANO AVE	91304	12	189B101   673	2013012020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Expired	11/09/2015 12:00:00 AM	ADDRESS	34.21208	-118.61652	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 24 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 3 STRINGS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20695	16041-20000-45495	8224 N LINDLEY AVE	91335	12	192B125   722	2101020005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.22015	-118.52717	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20696	19041-20000-29315	1811 W 27TH ST	90732	15	009B189   182	7563008003	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	33.72278	-118.31902	Install 13.5 kWh energy storage system and associated distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20697	13041-10000-01133	360 E 2ND ST #362 &364	90012	9	129A215   135	5161020028	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.04805	-118.24012	tenant improvement in existing offices-new subpanel and circuitsPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20698	18041-10000-03408	7405 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20484	-118.49233	REPLACE INDOOR AND OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20699	17041-20001-35189	8527 N SEPULVEDA BLVD	91343	6	192B145   119	2654020015	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM			PC Approved	04/27/2018 12:00:00 AM	ADDRESS	34.22544	-118.46799	04/27/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the roof-mounted PV module layout.*****Previous Work Description*****PV2. ROOFMOUNTED SOLAR SYSTEM &  CARPORT WITH ROOFTOP SOLAR SYSTEM (carport under application # 17041-20000-35194) SYSTEM SIZE: 60 KW AC TOTAL.Note: building permit: 17010-20000-03781	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20700	18041-10001-41703	6527 W COLGATE AVE	90048	5	135B173    54	5511042007	R1-1-O-RFA	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM			PC Approved	01/30/2019 12:00:00 AM	ADDRESS	34.06995	-118.36837	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE LEAVING MAIN BREAKER TO 100A AND UPSIZING THOSE CONDUCTORS TO #2 MINIMUM - DISCONNECT WAS ADDED FOR ENERGY STORAGE SYSTEM ORIGINAL PERMIT Plan check for a PV1 3.3KW AC roof-mounted system. Scopes includes (9) modules, (1) inverter, and (1) Energy storage system (power supply) interconnecting through the subpanel. Note. Portion of the permit fee is paid under 18041-90000-39440.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20701	18041-20000-35615	1708 N ALEXANDRIA AVE	90027	4	147B197   199	5589033052	C2-1D	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	04/01/2021 12:00:00 AM	ADDRESS	34.10214	-118.29821	new office building 800 amp service.  core and shell only.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20702	11041-20000-26708	6800 N OWENSMOUTH AVE Ste 100	91303	3	183B105   949	2138006044	P-1VL, [Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM			PC Approved	12/20/2011 12:00:00 AM	ADDRESS	34.19413	-118.60138	Existin office space.  Relocating and adding light fixtures in Suite # 100.  Plan check is for energy only.  Permit is under 11041-90000-24564	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20703	10041-20001-07138	16830 W VENTURA BLVD UNIT 200	91436	5	168B133   198	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM			PC Approved	06/07/2010 12:00:00 AM	ADDRESS	34.15886	-118.50032	PLAN CHECK ONLY. REVISION TO APPROVED PLANS TO INCLUDE CHANGES TO EXISTING FIXTURES IN CLASSROOMS. ALL WIRING ARE EXISTING TO REMAIN. TI TO OFFICES/ CLASSROOMS FOR PEPPERDINE UNIVERSITY. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20704	18041-10001-48684	419 S MCCADDEN PL	90020	4	135B185   283	5507014018	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.06623	-118.33729	Expedite per applicant request.Plan check for PV1 10KW AC / 9.75 KW DC roofmounted system with (30) modules, (1) central inverter, (3) energy storage systems, and (3) subpanels interconnecting through a new 200-Amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20705	15041-20000-00771	754 S WALL ST B	90014	14	126A211   123	5145005008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.04061	-118.24966	$0 permit fee due to senate bill 1222 from 2012PV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 60KW AC. TOTAL OF 260 MODULES. SINGLE INTERTER. NET METER PROJECT. SPECIAL NOTE: ARRAY IS INSTALLED ON 717 SAN JULIAN ST. THE POI IS LOCATED ON ADDRESSED ON SHOWN ON THIS PERMIT. PER APPLICANT. THIS IS THE ONLY PV INSTALLED ON THIS SERVICE. INSPECTOR TO FIELD VERIFY TOTAL BACKFEED TO UTILITY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20706	19041-10000-15692	15148 W BLEDSOE ST	91342	7	222B145   121	2506002030	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Issued	03/03/2020 12:00:00 AM	ADDRESS	34.30689	-118.46319	Installation of a 1000A 480/277V switchgear for future use to connect a PV SYSTEM((((((Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application # 19041-10000-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20707	13041-20000-22633	10100 W SANTA MONICA BLVD #410	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.06191	-118.41691	Change to lighting and switching in an existing high rise office building.  PLAN CHECK ONLY for Energy with Emergency lighting.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20708	13041-10000-03017	2481 N LILLYVALE AVE	90032	14	139-5A237  65	5220034026	PF-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	ADDRESS	34.0765	-118.16477	PERMIT SHALL BE OBTAINED AT PLAN CHECK COUNTER.T24 FOR TI TO 2 STORY OFFICE BUILDING.  21,000 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20709	18041-10000-01612	1055 S SERRANO AVE	90006	10	129B193   587	5080014052	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.05106	-118.3065	New Fire alarm system to a new apartment building. (1) new fire alarm panel and (123) FA Devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20710	12041-10000-26511	3760 S WADE ST	90066	11	111B153   321	4246029020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Expired	02/18/2015 12:00:00 AM	ADDRESS	34.00265	-118.43875	INSTALL ON THE ROOF OF A SFD A4.8KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20711	11041-20000-07493	11115 W HARTSOOK ST 1-24	91601	4	171B173   709	2353005027	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Apartment			04/13/2011 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.16403	-118.37295	FIRE ALARM.  1 PANEL, 80 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20712	11041-20000-20869	4921 W JEFFERSON BLVD	90016	10	120B181   743	5057028035	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.02566	-118.35162	energy plan check fire damaged paint booth	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20713	10041-10000-19348	12148 W HART ST	91605	2	183B165   274	2321009041	R3-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			09/29/2010 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.19731	-118.39828	New 25 units appartment building. Plan check for power and energy. (Variance for separate fire alarm system has been field.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20714	16041-20003-28164	22951 W ROSCOE BLVD	91304	12	192B097   589	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	PIN	34.22262962	-118.62405906	02/09/2018 Changes to an approved set of plan. All changes have been clouded and marked as Delta 6 and 7, which have been revised from the previous revision. Lighting fixture wattages and loads have been revised.*****Previous Work Descriptions*****Changes to approved set of plans - changes include addition to lighting system/photometrics, electrical equipment, relocation of panel, load redistribution and addition of new inverter to replace some areas with unit equipment. changes noted under delta 4, 5, 6, and 7.16041-20001-28164changes to an approved set of plans. plancheck only. changes noted delta 3.  changes include new UPS and relocation of panels and redistribution of loads. plan check for power only.   (((Plan check for power and energy. Project site is a new warehouse. Work includes a new 3000-amp service, associated distribution boards and load, and a total lighting area of 42,645 sq. ft.)))Note: Building application has been filed under 16010-10000-00122	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20715	15041-10001-08748	462 E COMMERCIAL ST	90012	14	130-5A215  46	5173001905	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05309	-118.23584	PC only due to lost approved set.This is 1 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************PC FOR POWER AND ENERGY. NEW 3000 A SERVICE FOR LOS ANGELES DEPT OF TRANSPORTATION FACILITIES CONSISTANT OF MAINTENANCE AND OPERATION BLD, PARKING STRUCTURE, TANK FORM BLDG AND SERVICE BLDG.(MAINTANANCE INCLUDES CLASS ONE DEVISION 2 AREA). TOTAL AREA (INDOOR 36875)  + (67828 OUTDOOR) 104703 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20716	19041-20000-53862	14256 W HAMLIN ST	91401	2	180B153   811	2237021002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.18849	-118.44404	PV1. INSTALL 6.6 KW DC ROOFMOUNTED PV SYSTEM WITH (20) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20717	19041-20001-12478	12147 W VENTURA BLVD	91604	2	162B165    22	2367016008	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.14356	-118.39685	08-23-2019 Changes to an approved set of plan, Changes include lighting fixture to different mannufacture. All changes has been clouded. plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20718	14041-20000-31875	4801 W PICKFORD ST	90019	10	126B181   741	5067010018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.04165	-118.34328	PV1 SFD TOTAL SYSTEM SIZE 3.8 KW AC USING CENTRAL INVERTER SYSTEM, TRANSFORMERLESS INVERTER. USING 12 MODULES IN TOTAL. NONSTANDARD PLAN.ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20719	12041-10000-30716	7561 S STEWART AVE	90045	11	099B161    37	4110030018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2012 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	33.97112	-118.41216	PV1 PLAN CHECK 8.8KW PHOTOVOLTAIC SYSTEM ROOF MOUNTED SINGLE FAMILY DWELLING TWO STORY [INVERTERS: PVI-3.6-OUTD-US AND PVI-5000-OUTD-US TRANSFORMERLESS][MODULE: SUNPOWER E20/327 SOLAR PANEL #SPR-327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20720	10041-10000-19997	25621 S NORMANDIE AVE	90710	15	036B197  1013	7413004035	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.20	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	33.79113	-118.29769	NEW FIRE ALARM SYSTEM. PLAN CHECK IS FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20721	18041-20000-21151	7000 W 3RD ST LEVEL 1&2	90048	5	138B177   793	5511027028	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07135	-118.36168	PLAN CHECK FOR TITEL 24 ONLY FOR INTERIOR NON-STRUCTURAL REMODEL OF EXISTING OFFICE SPACE ON 1ST AND 2ND LEVEL. TOTAL AFFECTED AREA = 8749 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20722	17041-20000-08086	5625 N CAHUENGA BLVD	91601	2	174B177   479	2415023011	CR-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.17293	-118.36172	ti to an existing commercia building.  adding new lighting new controls to new panels.  total connected load < 400 amps.  plan check for energy and em lighitng only.  total square footage 1981.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20723	18041-20000-15740	700 S FLOWER ST suite 700	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only in existing office T.I. Total area: 2,945 sq ft. B#18016-30000-09706	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20724	18041-20000-02490	7105 W SUNSET BLVD	90046	4	147B181   638	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.09814	-118.34455	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 474 sq. ft.Note: Building permit has been issued under 17016-20000-17354	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20725	12041-10000-00679	11201 N CHIMINEAS AVE	91326	12	210B125   164	2715031038	RE11-1	North Valley	Northridge	Northridge East		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2012 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.27418	-118.52877	New 5KW, rooftop mounted, photovoltaic system for an existing single family residence, with 24 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20726	15041-20000-39767	2939 S CATALINA ST	90007	8	120B197   300	5054036020	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Expired	12/28/2017 12:00:00 AM	ADDRESS	34.02751	-118.29385	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.5KWac. (10)MODULES-BOVIET 260W(1)INVERTER-FRONIUS GALVO 2.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20727	19041-20000-17074	5166 N LANKERSHIM BLVD	91601	2	171B173   634	2353005014	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.16457	-118.37421	T24 ONLY, PLAN CHECK FOR LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 1,033SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20728	16041-30000-07229	5418 W BEVERLY BLVD	90004	4	138B185   119	5515007002	A1-1XL-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	10/12/2021 12:00:00 AM	ADDRESS	34.07561	-118.32778	PLAN CHECK FOR REPLACEING AND EXPANDING GOLF COURSE MAINTENANCE FACILITY. NEW SERVICE 800A. TOTAL AREA INDOOR: 3,977 SQ FT. TOTAL OUTDOOR: 108,320 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20729	18041-20004-11355	20433 W NORDHOFF ST	91311	12	195B109    61	2781001036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.232	-118.57867	04/24/2019 Changes to an approved set of plans. Module count has been increased to (222) and model has changed as noted on single line diagram.09-17-2018 Changes to an approved set of plan changes include remove load center and add fused disconnect, and replace 2 inverter(33.3kW) to 1 inverter(66.6kW). Changes has been clouded. Plan check only.08/22/2018 Changes to an approved set of plans. Module count has been reduced to (218) and module model has changed. Inverter sizes have remained the same. *****Previous Work Description*****Plan check for a PV2 roof-mounted PV system. System size is 66.6 kWac and consists of (2) inverters, (233) modules, (1) transformer, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20730	19041-10000-52939	6427 W OLCOTT ST	91042	7	201B205   250	2570013020	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu, Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Closed	04/27/2022 12:00:00 AM	PIN	34.24948013	-118.27230511	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER WITH POWER OPTIMIZERS. (1) 5.0kw INVERTER AND (45) MODULES. TOTAL SYSTEM SIZE IS 5.0 KWAC/5.12 KWDC/4.35 KWAC CEC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20731	17041-10000-35009	110 E 9TH ST 10TH FLR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.04107	-118.25479	TENANT IMPROVEMENT, TO INCLUDE, 15,300 SQFT ON 10TH FLOOR, NON LOAD BEARING PARTITIONS, CEILING, AND FINISHES. NEW BATHROOMSPLAN CHECK IS FOR TITLE 24 AND 1 EA EM CKTB# 17016-10000-27747	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20732	18041-10000-22361	18039 W SHERMAN WAY	91335	3	183B125    45	2121002014	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.20134	-118.52674	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20733	14041-10000-04019	366 E 15TH ST	90015	14	123A209    39	5133020003	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.03271	-118.25954	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20734	16041-10001-17471	1840 S CENTURY PARK EAST 6TH	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	Changes to approved set. 6th floor.  scope of work includes reduction of luminaire throughout the floor plan, new fixtures were added to the fixture schedule. Changes under delta 6. ***********************************************************************************PLAN CHECK FOR ENERGY ONLY. TI REMODEL TO 6 FLOOR (HIGH RISE). TOTAL AREA 14705 SQFT. TOTAL ADDED LOAD LESS THAN 400AMP ADDING NEW LIGHTING AND POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20735	12041-20000-03783	8654 N SUNLAND BLVD	91352	6	195B177   477	2404026003	C2-1VL, R1-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Apartment			02/21/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	34.22745	-118.3659	34 units apartment building variance for fire alarm on file	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20736	17041-10000-45117	12765-12771 W SUNBURST ST	91331	7	204B161   418	2623025017	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.25468	-118.41095	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20737	14041-20000-30449	8031 N WILLIS AVE	91402	6	189B149   231	2209039031	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.21672	-118.45551	PV1Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP. System size: 7.31kW.34 EnPhase M215 microinverters connected to 34 250W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20738	15041-10000-19318	800 E D ST	90744	15	030B209   960	7424016030	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	33.77456	-118.25259	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FIXTURES. TOTAL AREA12676 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20739	10041-20000-25105	7901 N LINDLEY AVE	91335	3	189B125   489	2102014018	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.21431	-118.5275	Relocating 400 Amp distribution board, installing 2 new panels, branch circuits, air condition units, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20740	13041-10000-03388	1100 S CROCKER ST Suite #401	90021	14	124-5A211 313	5132010059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM			PC Info Complete	02/08/2013 12:00:00 AM	ADDRESS	34.03368	-118.25103	EDIT 2/20/2013: EXPRESS PERMIT PULLED ON 13041-10000-04281TI IN AN EXISTING COMMERCIAL SPACE (WAREHOUSE) IN Suite #401. PLAN CHECK FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20741	18041-10001-32116	3310 N VERDUGO ROAD	90065	1	153A215   332	5456001038	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			Reviewed by Supervisor	08/27/2018 12:00:00 AM	ADDRESS	34.11195	-118.23579	**expedited per applicant**Install New rooftop solar system on a Commercial Building, system size 13.2 kW DC/ 11.56 kW AC. Install (48) modules CSUN275-60P, and (48) Enphase IQ6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20742	15041-20000-10025												Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM				Plan check  for PV roof mounted system for tri-plex unit #2 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10020	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20743	14041-20001-04856	20500 W BLAIRMOORE ST	91311	12	207B109   501	2707012051	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.26242	-118.58012	Fee for expedite only.*****Roof mounted PV system with 4KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20744	16041-20000-29239	18321 W KINZIE ST	91325	12	201B125   177	2764003014	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.24832	-118.53273	PERMIT FEES $0.00 BY STATE SENATE BILL NO.1222PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20745	16041-10001-16401	611 E SANTA CLARA AVE	90291	11	108B145   803	4239025049	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	33.99267	-118.46628	PLAN CHECK FOR A LOST SET OF PLANS FOR A NEW PV SYSTEM.NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-16401	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20746	15041-10001-06714	1836 N DOHENY DR	90069	4	150B169  1192	5561008043	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM			PC Approved	05/01/2015 12:00:00 AM	ADDRESS	34.10553	-118.3879	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.7KW INTERCONNECTED WITH MSP.(51) CANADIAN SOLAR 260W MODULES(2) SUNNY BOY TL INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20747	19041-20000-41053	11881 W TERRA VISTA WAY #107	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/12/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20748	14041-10000-35391	20500 W PLUMMER ST	91311	12	198B109    58	2748041001	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.24249	-118.58064	Energy plan check for changing HID light with LED fixture in a commerical building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20749	15041-20000-26006	11027 N IRMA AVE	91042	7	210B193   616	2552040017	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.2694	-118.30092	Plan check for PV roof monted system. System size: 3.0kW with 13 modules and 1 inverter(3.0kW) Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20750	10041-10000-02664	3551 S TROUSDALE PKWY	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	08/11/2010 12:00:00 AM	ADDRESS	34.02066	-118.28531	Plan check for electrical re-model of theatrical rigging systems that includes upgrading two existing  400 amps theatrical dimming panels ckts only.  200 amps feed for loud speakers, power panel new, 100 amps, 1 relay panel and two more 100 amps panels.   No Title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20751	12041-20000-02486	5858 W WILSHIRE BLVD 203	90036	4	135B177   563	5089011002	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.06226	-118.3562	T24 for remodeled tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20752	16041-30000-22130	5762 W MORLEY ST	90045	11	093B169    61	4125011014	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	33.95362	-118.38262	Plan check for a fire alarm system for a new apartment building. System consists of (1) FACP, (1) communication panel, and (120) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20753	11041-10000-12330	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	Installation of  a new standby emergency generator.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20754	16041-20000-44610	12616 W VANOWEN ST	91605	2	180B161    41	2325002041	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	Apartment			12/20/2016 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	02/19/2021 12:00:00 AM	ADDRESS	34.19375	-118.40783	New 3-story 6-unit apartment building with private garage.  Connected load over 400A.  (2) new services - (1) 200A 240V 3ph and 400A 240V 1ph.  Plan check for power and energy.  Building permit under 16010-20000-01230	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20755	19041-20000-06362	734-738 N LA CIENEGA BLVD	90069	5	141B173   308	5528001064	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.08459	-118.37633	Plan check for new fire alarm system, 3 new duct smke detectors and 1 FACP with existing fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20756	14041-20001-01021	8134 W FOOTHILL BLVD	91040	7	204B193   156	2559001010	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.2595	-118.31045	CHANGE IN T24. CHANGE IN LIGHTING FIXTURE (B). RECHECK LTG FORMS. NO OTHER CHANGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20757	18041-10000-04978	9851 S ALAMEDA ST SHOPS 1	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	33.94801	-118.22929	PC FOR POWER ONLY, NEW SHELL 1-STORY WITH 6 RETAIL SPACE. SCOPE OF WORK INCLUDES NEW 1200 AMP, 120/208 V SWITCHBOARD,  HOUSE PANEL AND PANELBOARDS FOR FUTURE RETAIL SPACE. SITE LIGHTING IS UNDER A SEPARATE PLAN WITH APPLICATION NUMBER # E18LA00608. SITE LIGHTING AND EVCS ARE FED FROM SHOPS-2 POWER(JORDAN DOWNS PHASE 1C, SHOPS 1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20758	11041-10000-27403	1346 E 7TH ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM	12/27/2011 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	34.03531	-118.2395	Parking lot lighting. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20759	16041-20001-09172	5600 N OSTIN AVE	91367	3	174B089   424	2046007028	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM			PC Approved	03/29/2016 12:00:00 AM	ADDRESS	34.17235	-118.65324	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 175A.System size: 11kW (6+5). Ungrounded system. (54) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20760	19041-10000-00684	7104 W SUMMITROSE ST	91042	7	204B201    81	2565006036	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.25941	-118.28591	PLAN CHECK FOR ROOF MOUNTED 5.0KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 17 MODULES USING P320 OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20761	18041-10000-23002	865 S FIGUEROA ST SUITE 3200	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LOBBY AREA. 640 SQFT. SUITE 3200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20762	18041-10000-07761	733 S BERENDO ST	90005	10	132B197   320	5094009015	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM			Corrections Issued	03/02/2018 12:00:00 AM	ADDRESS	34.0588	-118.29429	New rooftop solar system on (1) of the (4) units apartment building. 3.0 kW AC/ 2.4 kW DC system (8) modules, and  (1) inverter.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20763	10041-20000-05547	20931 W BURBANK BLVD	91367	3	174B109   309	2149017013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Finaled	06/02/2010 12:00:00 AM	ADDRESS	34.1735	-118.58886	installing lighting fixtures and egress lighting in hall way in commercial place. This plan check is title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20764	17041-10000-17078	1709 E BENTON WAY	90026	13	144A207   176	5423027030	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.08855	-118.26567	ROOF TOP SOLAR - PC FOR PV SYSTEM RATED 10.4KW AC/ 13KW DC  USING 2 CENTRAL INVERTERS. PV LOAD CENTER AND 40 MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20765	17041-10000-02590	10250 W SANTA MONICA BLVD # 1775	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""2XU"" Ste. 1775.  Install new panels and its circuits, lights and receptacles. Total effected area: 1261 sq.ft. ."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20766	17041-20000-24951	9231 W KINGLET DR	90069	4	147B169   150	5561006017	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.10122	-118.3906	PLANCHECK FOR POWER.  PLANCHECK ONLY - ELECTRICAL PERMIT FEES PAID UNDER 16010-30000-01638.  NEW 2 STORY SINGLE FAMILY DWELLING. BUILDING PERMIT # 16010-30000-01638	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20767	15041-10000-22704	1149 S HILL ST 1ST FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.03926	-118.26099	ALTERATIONS IN  LOBBY  AND FACADE   PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20768	10041-20000-01723	1920 E MARENGO ST GROUND-2ND FLR	90033	14	132A223    49	5201016023	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2036.00	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM	02/26/2010 12:00:00 AM		Permit Finaled	04/06/2010 12:00:00 AM	ADDRESS	34.05739	-118.20965	CHANGE OF USE FROM COLLEGE TO MEDICAL CLINIC INCLUDES EXTERIOR AND INTERIOR TENANT IMPROVEMENT AND (N) BEARING WALL AND NON-BEARING WALLS; NEW T-BAR CEILING AND NEW ROOF AC UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20769	15041-10000-32902	1627 N RONAN AVE	90744	15	036B205   426	7414012017	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	33.79562	-118.27342	pv1, insatall 3.445 kw dc roof-mounted solar array on a single family house. (13) modules: KYOCERA KU2656ZPA(I) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20770	18041-20000-11908	451 N BRISTOL AVE	90049	11	135B137   541	4406006013	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.06377	-118.48889	Plan check for power only. Project site is a new 2-story single-family dwelling with an attached 3-car garage over a partial basement. Work includes a new 600-amp service.Note: Building permit has been issued under 17010-10000-02345. Electrical permit fees have been paid for under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20771	19041-10000-31964	501 E PACIFIC COAST HWY BLDG B	90744	15	036B209   517	7422009024	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			Corrections Issued	08/15/2019 12:00:00 AM	ADDRESS	33.79174	-118.25651	PLAN CHECK FOR TITLE 24 ONLY FOR (Interior/exterior alteration to (E) storage building).TOTAL AFFECTED AREA = 11752 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20772	19041-20000-39116	4209 N WOODMAN AVE	91423	4	165B157   841	2266021018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.14674	-118.43077	PV1.  Install 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20773	19041-20000-39647	8909 N CANBY AVE	91325	12	195B125   383	2769002021	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Issued	10/01/2019 12:00:00 AM	ADDRESS	34.2322	-118.53504	PV1. INSTALL 4.06 KW DC / 3.8 KW AC PV SYSTEM WITH (14) MODULES/OPTIMIZERS AND (1) INVERTER (SE3800A).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20774	11041-20001-23427	8211 W 3RD ST	90048	5	138B173   830	5511019034	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	34.07264	-118.36846	Revision to approved plans to include restroom in T24 Energy calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20775	14041-20000-05233	5825 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	33.97372	-118.41985	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN, roof-mounted.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20776	13041-10000-25141	947 S HOOVER ST	90006	1	130-5A201  12	5076006026	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Apartment			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.05376	-118.28439	FIRE ALARM OVER THE COUNTER PLAN CHECK. 1 NEW PANEL. 250 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20777	11041-20000-03381	2501 W COLORADO BLVD E	90041	14	163-5A219 173	5682014028	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.1416	-118.22117	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR T.I. - CHANGE OF USE FROM OFFICE TO A BEAUTY SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20778	17041-10000-04558	2225 S CARMELINA AVE	90064	11	123B149   849	4259026015	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.03006	-118.45548	Plan check for Title 24 only in exiting space T.I. DMC office. newly conncted load is less than 400A. Total area: 1,659 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20779	18041-10000-39628	13500 W SATICOY ST	91402	6	186B157   154	2303024018	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.20887	-118.42666	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20780	10041-10001-17266	1375 N WESTERN AVE	90028	13	147A193   170	5544030055	C2-1	Central	Hollywood	Hollywood Studio District		1909.01, 1911.10	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	PIN	34.09654211	-118.30960546	ADDED 100A PANELBOARD AND 8 EA NEW CIRCUITS; LIGHTING LOADS WERE INCREASED((((((((CHANGE PORTION OF EXISTING BLDG FROM REPAIR GARAGE TO RESTAURANT, 5800 SF, TYPE V-B CONSTRUCTION, OCCUPANCY CHANGE FROM F-1 TO A-2. TI CONSISTS OF INTERIOR WORK, NEW RESTROOMS, EQUIPMENT, DINING/SEATING.  REF.#10042-10000-19412.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20781	16041-30000-30753	3313 S BUTLER AVE	90066	11	117B157   123	4250019004	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.02003	-118.43039	Plan check for PV roof mounted system. System size:9 kW with 36 AC modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20782	14041-20000-29272	10908 W MESETA DR	91040	7	204B173   192	2542031009	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.25499	-118.3678	PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM. USES COMBINER BOX WITH 4 STRINGS. TOTAL OF 40 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20783	12041-20000-02761	20119 W VANOWEN ST	91306	3	183B113   868	2135032012	P-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM			PC Info Complete	02/07/2012 12:00:00 AM	ADDRESS	34.19398	-118.57176	T.I. to existing building ( Dog Grooming). Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20784	11041-10000-23134	501 W 6TH ST 1st floor	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	PIN	34.04872199	-118.25441618	T24 and emergency lighting plan check for Pacific Center on the first floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20785	18041-10000-29363	601 W 5TH ST Suite 640	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.05049	-118.25386	FULL PLAN CHECK FOR - CHANGE OF USE FOR A PORTION OF SUITE 650 FROM OFFICE TO DENTAL OFFICE (NEW SUITE # 640) TOTAL NEW CONNECTED LOAD = 100A APPROX. TOTAL AFFECTED AREA 1075 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20786	19041-10000-49187	7619 W BEVERLY BLVD	90036	5	138B177   417	5526042016	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.07629	-118.35605	T-24 ENERGY PC FOR A BEAUTY SALON. TOTAL AFFECTED AREA 1124sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20787	17041-10000-28131	12250 W VENTURA BLVD	91604	2	162B165   241	2369004025	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.14289	-118.4003	PC FOR Fire damage repair of portion of mezzanine and roof framing AND Upgrade (e) bathroom for TITLE-24 ENERGY ONLY. TOTAL AFFECTED AREA 4815 SQ.FT. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS.B# 17016-30000-19689	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20788	18041-10000-42410	11201 W PENDLETON ST	91352	6	198B173    66	2538010006	M2-1-G-CUGU, M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.23702	-118.37541	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20789	18041-20000-29011	4824 N SUNNYSLOPE AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.15859	-118.42562	new fire alarm system 118 devices plus FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20790	12041-20001-30756	12001 W VICTORY BLVD	91606	2	180B165   700	2322007056	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	05/09/2013 12:00:00 AM	ADDRESS	34.18684	-118.39464	Plan check for power and energy.  Bakery and kitchen. Less than 100 occupants. Electrical work was within the scope of work for the Civil Engineer. 8419sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20791	19041-10000-48642	10345 W OLYMPIC BLVD	90064	5	129B161   114	4319006052	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.05186	-118.41853	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS. TOTAL AFFECTED AREA IS 18,103. NOTE INDOOR AND OUTDOOR LIGHTING WERE SEPARTED BUT WILL BE UNDER ONE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20792	18041-30000-08082	3937 S VERMONT AVE	90037	8	117B197  1061	5037022024	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Closed	08/17/2018 12:00:00 AM	ADDRESS	34.01363	-118.2919	Plan check for fire alarm system for Charter school. Total fire alarm devices: 146 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20793	18041-20000-38463	5367 N WINNETKA AVE	91364	3	171B113    69	2166006007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.16778	-118.5711	pv1extend existing roof mounted pv system with 7.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20794	16041-20000-02429	321 S HAMPTON DR	90291	11	109-5A143  20	4286004007	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	33.99591	-118.47661	TI to existing commercial building (offices). Adding new lighting. Plan check for energy only. Total sqft. 474	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20795	18041-20000-23625	6416 N ELLENVIEW AVE	91307	12	180B085   164	2032025001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.18599	-118.65775	PV1.  Install 13.4 kW AC roof mounted grid tied PV system.  (41) modules with (2) 7.6 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20796	14041-10000-32111	1654 S GREENFIELD AVE 1-8	90025	5	129B153   553	4324030010	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			11/18/2014 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.04935	-118.4417	Full plan check for a new 4-story 8-apartment units building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20797	11041-20000-22746	17624 W MAYERLING ST	91344	12	213B129   410	2601069003	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2011 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.28331	-118.51728	New ground mounted P.V. system with 13.32 Kdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20798	14041-10000-02027	1755 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   269	5035008016	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.01102	-118.31079	PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE FROM (E) RETAIL TO (N) COIN LAUNDRYMAT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20799	18041-10000-32903	7007 W ROMAINE ST	90038	4	144B181   604	5532030011	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	05/15/2019 12:00:00 AM		Issued	05/15/2019 12:00:00 AM	ADDRESS	34.08901	-118.34188	FULL PC FOR A FIRST TIME OFFICE TI. SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS TO AN EXISTING MAIN DISTRIBUTION BOARD. TOTAL SQ. FT. 17349.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20800	17041-20001-19461	1604 S PACIFIC AVE	90291	11	106-5A145   4	4238014009	C2-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	33.98767	-118.47174	[[[6/27/17 CHANGES TO APPROVED T24 ENERGY. CHANGES TO THE LOCATION OF OVERRIDE SWITCH AND SEPARATE SWITCHING OF LIGHTING IN THE SECONDARY DAYLIGHTING AREA]]]]TI to (E) restaurant space.  Plan check for energy.  849 sq ft.  Electrical permit previously issued under 17041-90000-17925	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20801	12041-10000-13643	1550 N GLENDALE BLVD	90026	13	142-5A209 308	5419018020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Issued	06/29/2012 12:00:00 AM	ADDRESS	34.08312	-118.25974	"T.I. to an existing retail space.  Change to lighting and receptacles.  Load is 363 Amps.  Plan check only for Energy, with Emergency lighting.  Variance has been paid to use unapproved equipment for the LED light fixtures.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20802	19041-10000-51776	5530 N MELVIN AVE	91356	3	174B117   416	2164016002	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	ADDRESS	34.17134	-118.55954	PV1. NEW SOLAR SYSTEM ON EXISTIN RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.08KWdc / 10.0KWac WITH A TESLA STORAGE BATTERY. (28)MODULES-SOLARIA (POWERXT-360R-PD)(28)OPTIMIZERS-SOLAREDGE P400(1)INVERTER- SOLAR EDGE H-WVE SE10000H-US(1)TESLA POWERWALL BTTERY	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20803	12041-20002-21822	4144 S GLENCOE AVE A-B	90292	11	108B153  1207	4230006008	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	04/19/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	33.98891	-118.44171	Modification to previously approved plans to combine two separate services into one 3-phase 800 amp service.    <<<PLAN CHECK POWER AND ENEGY FOR TENANT IMPROVEMENT OF AN EXISTING OFFICE BUILDING.  BUILDINGS A & B>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20804	13041-10000-00952	10706 W VICTORY BLVD	91606	2	180B177   276	2414009***	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Apartment			01/14/2013 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.18649	-118.364	PLAN CHECK FOR FIRE ALARM. REMOVE AND REPLACE DEFECTIVE FACP WITH NEW FACP AND 1 SMOKE DETECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20805	10041-10000-12859	1300 E PLAZA DEL SOL	90033	14	129A219   343	5173029947	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.04854	-118.22564	New PV System on Commerical  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20806	17041-10000-39112	120 E LEROY ST	90012	1	135A217    52	5409011901	UV(CA)	Central	Central City North			2060.10	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.06513	-118.22947	INSTALL NEW FIRE ALARM  SYSTEM ON A (N) STATE APPROVED MODULAR FOR CHILD CARE FACILITY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20807	18041-20000-43073	16830 W VENTURA BLVD #400/415	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check for Title 24 only. Project site is a tenant space in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 660 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20808	13041-10000-34328	652 S MAIN ST	90014	14	127-5A211 120	5148021012	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Expired	01/05/2016 12:00:00 AM	ADDRESS	34.04404	-118.25097	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 752 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20809	12041-10000-31201	12241 W SANTA MONICA BLVD	90025	11	126B145   772	4263027017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.03984	-118.46546	T24. PC FOR ENERGY. TI CHECK CASHING TO RESTAURANT(WINGSTOP)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20810	16041-10000-23023	5200 N LANKERSHIM BLVD	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM			PC Info Complete	06/30/2016 12:00:00 AM	ADDRESS	34.16511	-118.37448	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS FOR THE LOBBYAND RESTROOM AREA. TOTAL AFFECTED AREA IS 2530 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20811	18041-10000-23712	3643 W WILSHIRE BLVD	90010	10	132B193    22	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	06/22/2021 12:00:00 AM	PIN	34.06199409	-118.30448162	"FULL PLAN CHECK (POWER + ENERGY) FOR NEW PROGRAM AND EVENT BUILDINGON WILSHIRE BLVD &  TEMPLE: ""AUDREY IRMAS PAVILION""; 3 STORY W/ROOF DECK AND MEZZANINE(B# 18010-10000-01758)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20812	16041-20000-35327	13836 W HAYNES ST	91401	2	180B153   719	2238016006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.18929	-118.43469	Plan check for installation of pv system on SFD, roof-mounted. Interconnect with 200A MSP. 3kW ungrounded system. (16) 255W pv modules. Each module has a 300W power optimizer.There is an existing 3kW ungrounded system on the building.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20813	12041-10001-06599	10250 W SANTA MONICA BLVD # 137	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM			PC Approved	07/20/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	Revision to approved plans. Revise lighting layout. Plan check is for Title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20814	16041-30000-15811	9200 N OAKDALE AVE 2nd Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 20,945 sq. ft.Note: Building application has been created under 16016-10000-09209	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20815	17041-10000-39228	710 E PICO BLVD	90021	14	123A211    85	5132019005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.03237	-118.25355	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20816	17041-20000-13042	13027 W STRATHERN ST	91605	2	189B161  1196	2304015029	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.21599	-118.41713	PV1.  Install roof mounted grid-tied PV system sized 8.9 kW interconnected with MSP.  Main disconnect rating reduced to 150A on center-fed panelboard.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20817	14041-10000-08093	3571 S CIMARRON ST	90018	8	120B189  1213	5042024005	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Expired	04/20/2016 12:00:00 AM	ADDRESS	34.02295	-118.31571	PV1 2.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(10)modules: {Trina {TSM-250PA05.08}}]SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20818	18041-10000-26201	2035 N HIGHLAND AVE 1ST FLOOR	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.10759	-118.3376	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR  (E) OFFICES  AT (E) NON PROFIT CLUB. ST FLOOR. 6927 SQFT. BUILDING PERMIT # 18016-20000-03314	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20819	19041-20000-16679	1101 S MAIN ST	90291	11	108A143   130	4238001046	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Closed	06/05/2019 12:00:00 AM	ADDRESS	33.99114	-118.4735	temp power for construction site 800 amp service.  plan check for power.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20820	19041-10000-52821	1811 W PICO BLVD	90006	1	129A203   405	5137034021	CM-1	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.04586	-118.27921	PLAN CHECK FOR A FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES INSTALLTION OF 1 FIRE ALARM CONTROL PANEL, 1 COMMUNICATION PANEL, AND 31 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20821	15041-10000-25043	4371 S GLENCOE AVE	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Issued	08/10/2015 12:00:00 AM	ADDRESS	33.9857	-118.43834	Remodel of (E) T-Mobile retail location.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20822	19041-10000-18977	615 S WESTLAKE AVE	90057	1	133-5A203 185	5141001034	C1-2	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Issued	05/31/2019 12:00:00 AM	ADDRESS	34.05852	-118.27408	T-24 PLAN CHECK FOR A TI TO ELEVATOR LOBBIES IN A 5 STORY HOTEL. SCOPE INCLUDES NEW EQUIPMENTS, LIGHTING, CONTROLS AND RECEPTICALS. NEW 41KVA ELEVATOR WITH NEW 250A SUBPANEL SUPPLIED FROM AN EXISTING 800A SERVICE AND SBD. TOTAL AFFECTED AREA IS 609 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20823	15041-10001-04696	801 S OLIVE ST	90014	14	127-5A209  31	5144019018	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.04514	-118.25715	12/16/2016 Changes to an approved set of plan. Changes include add 2 fire pump disconnect with in the Fire pump room. Changes has been clouded as delta 2. {{{{{{PLAN CHECK FOR POWER AND ENERGY FOR NEW 33-STORY TYPE 1A MIXED USE BUILDING WITH 363 RESIDENTIAL UNITS AND 10,000 SF COMMERCIAL USES OVER 2-LEVEL  SUBTERRANEAN PARKING.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20824	17041-10000-04614	20179 W RINALDI ST BLDG A3	91326	12	213B113   266	2701004047	(T)C4-2D, A1-2D, [T]C2-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.27523	-118.57313	PC FOR POWER AND ENERGY. BUILDING A3  NEW CONSTRUCTION -SHELL ONLY  1 STORY, SERVICE 1200A, 277/480 V, TOTAL AREA 4658 SQ FT. BUILDING APP 16010-10000-06136	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20825	19041-10001-42961	1213 N AMALFI DR	90272	11	129B133    96	4425007013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM			PC Approved	06/15/2020 12:00:00 AM	ADDRESS	34.05187	-118.50615	NEW ROOF MOUNTED 14 KW, WITH (38) SOLAR MODULES (370W) AND TWO 11.4KW BATTERY SYSTEM ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20826	13041-10000-36010	8500 W BEVERLY BLVD 2ND FLOOR	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	INTERIOR REMODEL OF 2ND FLOOR IN THE BEVERLY CENTER. PROJECTED ARE IN LIGHTING SCOPE OF WORK IS APPROX. 44,000 SQ FT. TAILOR METHOD FOR COMPLIANCE APPROACH. SIGN LIGHTING WILL ALSO BE INCLUDED ON THE COMPLIANCE FORMS.BUILDING PERMIT UNDER: 13016-10000-26364	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20827	18041-20000-06437	3139 N CHANDELLE ROAD	90046	4	156B177    37	5570023034	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.12757	-118.3647	Plan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.11.4kW unground pv system. (27) modules with P400 optimizers and (3) 14kwh Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20828	18041-20000-26123	8700 W BURTON WAY 1-30	90048	5	138B169   722	4334015035	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.07196	-118.38193	Plan check for a PV2 roof-mounted PV system. System size is 48.47 kWdc/43.5 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (131) modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20829	19041-10000-44810	615 W 57TH ST	90037	9	108B201  1066	5001020019	R2-1	South Los Angeles	South Los Angeles	Voices		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	33.99066	-118.2846	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (15) MODULES AND OPTIMIZERS AND (1) 5KWAC INVERTER. TOTAL SYSTEM SIZE IS 5KWAC/4.65KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20830	13041-10000-35781	2403 W 4TH ST	90057	1	135A203   203	5154035003	R3-1	Central	Westlake		YES	2088.02	Electrical	Electrical	Apartment			12/23/2013 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.06409	-118.27662	PV2. APARTMENTS  ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19.2 KW DC. CENTRAL INVERTER.(64) RENESOLA JC300(2) SMA SB6000US(1) SMA SB7000US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20831	17041-10000-28457	649 S OLIVE ST	90014	14	129A209   151	5144003904	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.047	-118.25536	PC FOR POWER ONLY. KITCHEN TI PACKAGE. CORE AND SHELL UNDER APPLICATION PCIS#16041-10000-22842	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20832	15041-20000-23956	13042 MESA VERDE WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	PIN	34.31120672	-118.40409465	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20833	17041-20000-24721	3015 S HOOVER ST STE 186	90007	9	121-5A201 147	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM			PC Info Complete	07/21/2017 12:00:00 AM	ADDRESS	34.02712	-118.28423	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20834	17041-20001-37274	4721 N KRAFT AVE	91602	2	168B169   632	2354013063	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.15636	-118.38022	EXPEDITED PER APPLICANTS REQUEST.ADDITION TO AN EXISTING PV SYSTEM . PV1. ROOFMOUNTED. SYSTEM SIZE: 4.2 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20835	16041-20003-10517	19524 W NORDHOFF ST #11	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.23527	-118.55871	8.30.2016 - Plan check for modifications to approved set. Luminaire changes have been made. All changes have been reflected onto the Title 24 compliance forms. All changes have been clouded and marked as Delta 4.====8.16.2016 - Plan check for modifications to approved set. Replacing Leviton current limiter panel with 1A Lithonia current limiters on each track. Updated T-24 forms to reflect change. Delta 3 changes.====7.19.2016 - Plan check for modifications to approved set. Update plan to correctly reflect existing service and panel configuration in tenant space. Change bathroom lighting control from dimmer switch to combined occupancy sensor and dimmer switch.====Plan check for energy only. Change of use from restaurant to music studio. New lighting (incl. emergency). 4,515sqft. Electrical permit pulled under permit #16041-20000-05567	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20836	18041-10000-20024	1395 N VINE ST BLG D	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/19/2020 12:00:00 AM				NEW FIRE ALARM SYSTEM IN A NEW COMMERCIAL BUILDING.BUILDING PERMIT #15010-10000-04706	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20837	19041-10000-42226	401 WORLD WAY F/A	90045	11	090B161    37	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/27/2021 12:00:00 AM	ADDRESS	33.94281	-118.40686	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK INCLUDES A NEW FIRE ALARM PANEL, 9 REMOTE POWER SUPPLIES, AND 183 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20838	15041-10003-02728	6325 W RODGERTON DR	90068	4	157-5A189 162	5582010019	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.12578	-118.32282	Change to approved set by updating and derating the sub panel breaker  for the main service. All changes are dunder delta-1 only.(((PV1, 8250 W DC GROUND -MOUNTED SOLAR ARRAY IN A ONE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL. 3 STRINGS. ONE INVERTER: SMA AMERICA SMA-SB7000-US(33)MODULES: PHONO SOLAR PS250P)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20839	10041-20000-05862	901 W WASHINGTON BLVD	90015	1	124-5A203  18	5124017001	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2242.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.03718	-118.27781	revise parking lot lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20840	14041-20000-11230	700 S FLOWER ST 26th floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI - ENERGY PLAN CHECKExisting high rise building, 26th floor core and shell remodel (2,310 sqft).Plan is using 2013 CEC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20841	17041-20001-45585	1126 1/2 N LEMOYNE ST	90026	13	139-5A209 214	5404017008	R3-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Apartment			12/19/2017 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.07635	-118.25991	Expedited plan check fee.PV2.  Install 3.54 kW roof mounted grid tied PV system.  (12) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20842	19041-10001-01293	961 S GRETNA GREEN WAY	90049	11	129B145   957	4264023016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.0466	-118.47066	EXPEDITE FEEPLAN CHECK FOR ROOF MOUNTED 76KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 29 MODULES USING P400 OPTIMIZERS AND 2 13.5KWH AC BATTERIES(TESLA POWER WALLS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20843	18041-10002-07714	3016 S SOMERSET DR	90016	10	120B185   529	5050030040	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.02706	-118.33724	SUPPLIMENTAL FOR THE ENERGY STORAGE SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20844	19041-20000-26575	1840 S CENTURY PARK EAST 15th flr	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.06188	-118.41473	ti to an existing commercial building (office spaces).  adding new lighting new controls to existing panels. plan check indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20845	13041-20002-16541	17123 W ADLON ROAD PV-1	91436	5	165B133   478	2292011006	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.14554	-118.50642	PV-1. two 3.6kW Transformerless and one 7kW transformer equipped inverter.(( cdhanges to approved set of plans. new location for inverters inside garage. location okay. no changes to electrical system.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20846	18041-20000-03177	23334 W COLLINS ST	91367	3	174B093   273	2041011021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.17355	-118.63519	pv1install roof mounted pv system sized 9.8kw interconnetced with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20847	19041-10000-38944	21255 W BURBANK BLVD SUITE 300	91367	3	174B105    87	2149019018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM			Not Ready to Issue	09/26/2019 12:00:00 AM	ADDRESS	34.17432	-118.59446	THIS IS A PLAN CHECK ONLY FOR A TI TO AN EXISTING FIRE ALARM SYSTEM. SCOPE OF WORK IS ADDING DEVICES AND BATTERIES TO EXISITNG FIRE ALARM SYSTEM SPANNING THREE FLOORS. THIS IS THE THIRD FLOOR PORTION CONSISTING OF 134 DEVICES, AND TWO BATTERY. NOTE ALL FLOORS HAVE BEEN SEPARATED INTO THREE APPLICATIONS, ALL HAVE BEEN APPROVED BY FIRE. NOTE THE PERMIT FOR THE THIRD FLOOR HAS BEEN PULLED UNDER 19041-10000-38176	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20848	13041-10000-08377	17501 W SUPERIOR ST	91325	12	201B129   260	2755014012	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.24684	-118.51586	PV1 PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 17.9 KW. USING 73 PANELS. USING 2 TRANSFORMED INVERTERS. NONSTANDARD PLAN. ADDITION OF LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20849	18041-10000-40412	8500 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.22485	-118.50045	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20850	13041-10001-07013	9727 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	08/28/2013 12:00:00 AM	ADDRESS	34.24624	-118.4193	PLAN CHECK ONLY. REVISION TO APPROVED PLANS. DELTA 7 ONLY. CHANGES TO BUILDING LAYOUT, LIGHTING, AND REMOVE SUMP PUMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20851	11041-20000-04353	777 S FIGUEROA ST #34TH-35TH FLR	90017	9	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	05/06/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.04828	-118.26116	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TWO TENANT FLOORS:  34 & 35.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20852	19041-20001-31250	12113-12115 W VENTURA BLVD	91604	2	162B165   107	2367016014	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.14366	-118.396	Plan check for Title 24 only in existing space relocate lighting fixtures remove and reinstalled more than 10 percent in enclosed space. Total area: 4697 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20853	17041-20001-11934	8700 N VAN NUYS BLVD	91402	6	195B149   659	2638001034	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.22745	-118.4499	PC FOR PWR AND T-24. REVISION TO APPROVED PLANS. DELTA C REVISION ONLY. MISC SLD CHANGES, MISC CHANGES TO PANEL SCHEDULES, REDUCTION OF LTG. OMISSION OF DIMMER SWITCHES.ORIG APPROVED SET # 17041-20000-11934ORIGINAL SCOPE : TENANT IMPROVEMENT TO MARKET.   PLANCHECK FOR POWER AND ENERGY. BUILDING PERMIT # 17016 20000 06946	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20854	15041-10000-05842	4605 W DON MIGUEL DR	90008	8	114B177   417	5028019024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.00531	-118.35657	PV1.   13 kW roof-mounted system. Scope includes (52) YingLi YL250p modules, (1) combiner box,  and (1) 11.4kw Fronius IG inverter interconnceting through the main service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20855	13041-20002-11045	1305 S ABBOT KINNEY BLVD	90291	11	108B145  1166	4239027002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM			PC Approved	08/06/2014 12:00:00 AM	ADDRESS	33.99127	-118.46797	REDUCE LOAD ON OUTDOOR HEATER. REDUCE DISHWASHWER LOAD TO 20A. REVISE LOAD CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20856	19041-10000-10470	1031 S BROADWAY 10TH FL	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	05/14/2024 12:00:00 AM	ADDRESS	34.04041	-118.2583	Full PC Power and Enegrgy, scope include installing 5 New panels from (E) 600A Dist. board, scope Area 16,050SqFt	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20857	11041-20000-03589	11342-11350 W BURBANK BLVD	91601	4	174B173   951	2350008015	C2-2D	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.17194	-118.3778	Plan check power and energy for new for 5 story hotel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20858	19041-20000-06169	4441 N LA BARCA DR	91356	3	165B117    27	2177002018	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.15177	-118.55175	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. TOTAL SYSTEM SIZE IS 11.4 KW AC, SCOPE OF WORK INCLUDES (35) CANADIAN CS3U-370 WITH P400 OPTIMIZERS, (1) SE11400A-US INVERTER, NO MAIN SERVICE PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20859	19041-20000-26591	14020 N CAROL LANE pv1	91342	7	228B141   518	2603026016	(Q)R1-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.32009	-118.48248	pv1install roof mounted pv system sized 5.2KW AC interconnected with msp.  (1) ESS rated 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20860	19041-20000-14257	8006 N BROADLEAF AVE	91402	6	189B153   378	2213006002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.21661	-118.43794	PV1.  Install 3.96 kW DC / 3.6 kW AC roof mounted grid tied PV system.  (12) modules with 3.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20861	13041-20001-08764	8990 W NATIONAL BLVD	90034	10			M1-1	West Los Angeles				2701.00	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.03085	-118.39063	BAKERY 600 A SERVICE(((SUPPLEMENTAL APPLICATION FOR CHECK ON SERIES RATING. VERIFY SERIES RATING TYPE ONLY. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20862	19041-20000-34428	22843 W MARIANO ST	91367	3	171B097    30	2042008058	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.16892	-118.6248	Plan check for PV roof mounted system, PV system size: 19.8KW DC, 18.51KW AC with 60 PV Modules and 2 inverters(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20863	19041-20000-41044	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20864	14041-20000-29535	14801 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	34.17768	-118.45513	T.I. to existing building.  Install lighting in restrooms.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20865	16041-10000-07175	850 S OLIVE ST	90015	14	127-5A209 127	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Issued	05/16/2016 12:00:00 AM	PIN	34.04378232	-118.2577565	FIRST TIME TENANT IN A  HIGHRISE MIXED-USE BUILDING, ICE CREAM SHOP,  FULL PC. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES AND A TRANSFORMER. .TOTAL AREA: 661SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20866	13041-10000-19731	500 S GRAND AVE	90013	14	130-5A211 157	5149030001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	PIN	34.04986225	-118.25376975	Replacement of existing fire alarm control panel from XL-3 to MXL to replace the existing fire alarm control panel that had suffered water damage.  Use of conversion kit to allow mounting MXL equipment in existing XL-3 enclosures, and installation of XLD-1 Series Loop Driver to allow compatibility of MXL with existing initiating devices.  Notification and initiation devices are all existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20867	16041-10000-37050	6809 N LAUREL CANYON BLVD	91605	2	183B165   644	2321026050	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.19426	-118.39687	PC for title 24. Energy only. Scope includes replacment of new LED fixturesTotal affected area of 9425 sq.ft. (outdoors)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20868	19041-10000-35253	3476 E WHITTIER BLVD A-1	90023	14	121-5A227 196	5188017001	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.0265	-118.19877	"CHANGE OF USE FROM RETAIL TO ""WING STOP"" RESTAURANT. Installing lights, 2 new panels and new circuits. T-24 Energy only. 1475 Sqr Ft. Building Permit: 19016-20000-18623"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20869	19041-10001-04084	2802 S ELLENDALE PL	90007	9	123B197  1550	5055012021	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.02947	-118.28859	changes to approved set of plans - changes include module modification (solarcity standard #sc330)original permit PV2, PLAN CHECK FOR A NEW ROOF MOUNTED PV SYSTEM INSTALLED IN A MULTI UNIT PROPERTY. TOTAL OF 18 MODULES AND (1) 5.2 KW AC INVERTER. 5.85 KWDC / 5.2KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20870	16041-20000-05935	10614 W RIVERSIDE DR	91602	4	165B177   108	2423003029	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.15204	-118.36207	Plan check for power and energy. Project site is an existing commercial 2-story building. Project scope is a change of use from office to medical office and a tenant improvement. Total lighting area = 3,041 sq. ft.Note: Building permit has been pulled under 15016-20000-14297	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20871	12041-10000-21378	11013 N WESCOTT AVE	91040	2	210B189   157	2551044019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.26926	-118.31771	ROOF INSTALLATION OF 4.16 PHOTOVOLTAIC SYSTEM USING MICRO INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20872	16041-20000-03241	1456 N ANGELUS AVE	90026	13	142-5A205 254	5424015005	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Expired	03/13/2018 12:00:00 AM	ADDRESS	34.08491	-118.26865	Plan check for a backup battery bank  5kW  for an existing PV system on a Single Family Dwelling. PV system is utility-interactive.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20873	18041-20001-44520	741 S BOYLE AVE	90023	14	124-5A221  58	5183021018	R3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Apartment			01/23/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.03684	-118.21912	Work description correction: PV2.  Install 8.58 kW roof mounted grid tied PV system.  (26) modules with 7.6 kW rated string inverter.Plan review for apartment PV plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20874	17041-10000-06704	2516 W AVENUE 33	90065	1	150B213   181	5456002033	R2-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.11059	-118.23516	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR) TOTAL AREA 40500 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20875	11041-20000-23345	8500 W BEVERLY BLVD Space# 150	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	11/10/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I for existing office space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20876	15041-20000-29398	14991 W VALLEY VISTA BLVD	91403	4	165A147   164	2276025014	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Closed	06/06/2017 12:00:00 AM	ADDRESS	34.14672	-118.46096	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (1) combiner box, and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20877	16041-10000-07133	534 S OCCIDENTAL BLVD	90057	1	135A201   113	5155011016	C2-2	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.06389	-118.2838	TI TO (E) STARBUCKS. CHANGE ALL INTERIOR LAY OUT AND DINING. 2 NEW PANELS WITH CONNECTED LOAD <400A. PC FOR ENERGY ONLY, TOTAL AREA 2,365 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20878	14041-10000-02733	154 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.07457	-118.32342	PLAN CHECK ONLY FOR TITLE-24 ENERGY PER INSPECTORS REQUEST , TENANT IMPROVEMENT WORK FOR A BAGEL STAND. 822 SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 13041-10000-23232.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20879	18041-20000-18378	1520 N CYPRESS AVE	90065	1	147A217   190	5454035036	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.09779	-118.23221	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 780 sq. ft.Note: Building application has been generated under 18016-20000-13197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20880	15041-20000-19684	12300 W VENTURA BLVD	91604	2	162B165   245	2369002029	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Issued	06/23/2015 12:00:00 AM	ADDRESS	34.14282	-118.40098	Plan check for Title 24 only for retail space. Total area: 750SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20881	15041-20000-27751	700 W 9TH ST	90015	14	129A207   333	5138017***	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.04579	-118.2618	Plan check power and energy for new High-rise 31-story with 281 units. Total inddor area: 31,520 sqft.  Note: Applicant has pre-cut check; plan check engineer shall verify the number of circuits and panels one more timeFire alarm Variance has been filed 08-24-2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20882	10041-20000-20672	15742 W SAN FERNANDO MISSION BLVD	91344	12	210B141   586	2662012018	RS-1, T	North Valley				1093.00	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	PIN	34.27153203	-118.47547916	Plan check for installation of 16.8KW Photovoltaic System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20883	18041-20000-06902	8636 N MASON AVE	91306	3	195B109   389	2781007027	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	PIN	34.22751494	-118.57942769	pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20884	13041-20000-27530	18001 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.26501	-118.52523	T24 FOR CHANGE OF USE TO BANK. SQRFT 1930	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20885	17041-10002-21313	2805 S MCCONNELL DR	90064	5	126B165   650	4308014010	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.04091	-118.40132	Supplemental fees for expedite rooftop solar.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20886	15041-10000-43028	17383 W SUNSET BLVD A-310	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.03917	-118.55529	INTERIOR TENANT IMPROVEMENT TO (E) OFFICE.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20887	13041-10000-10388	3550 W WILSHIRE BLVD #1800	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.06157	-118.30226	TI OF TRAININ ROOM. PART OF HIGH RISE. TOTAL AREA 690 SQ FT. SUITE # 1800. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20888	14041-20000-30476	1640 S SEPULVEDA BLVD 214-218	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.04838	-118.44468	T.I. to existing building on the 2nd Floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20889	13041-10000-08964	8718 W 3RD ST	90048	5	138B169   569	4334011056	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM			PC Approved	04/08/2013 12:00:00 AM	ADDRESS	34.07344	-118.38221	TI , Title 24 only restaurent remodel.   service is 200 amps.  panels and circuits to be charged under permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20890	15041-10001-36806	12615 W BEATRICE ST	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	33.98049	-118.41636	PC FOR POWER ONLY. UPGRADE SERVICE/DISTRIBUTION BOARD TO 2000A.NOTE: PERMIT IS PULLED UNDER PCIS#15041-10000-36806(((((UPGRADE SERVICE TO EXISTING EMPTY BUILDING; FEEDERS ARE STUB-UP;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20891	15041-10000-16279	3700 N COLDWATER CANYON AVE 1ST FL	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.13809	-118.41286	NEW LUMINAIRES IN OFFICES IN THE SEAVER ACADEMIC CTR ON THE HARVARD WESTLAKE CAMPUSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20892	10041-20000-15052	1969 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM			PC Approved	08/03/2010 12:00:00 AM	ADDRESS	34.06159	-118.20463	Revision to 10041-10000-06618.  Locating local lighting control for light fixtures. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20893	14041-10000-17775	13405 W BURBANK BLVD 1-5	91401	2	174B157   600	2343015031	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			07/01/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.17234	-118.42496	install new sprinkler monitoring system for R occupancy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20894	14041-10000-19897	12836 W HORTENSE ST	91604	2	168B161   792	2362019016	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.15481	-118.41299	PV1, INSTALL 10.46 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(41) MODUES: TRINA SOLAR TSM -255PA05.18(2) INVERTER(s): SE5000-US-ZB-U & SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20895	12041-10000-03129	3932 W SUNSET BLVD	90029	13	145-5A203 363	5427007031	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM			PC Approved	02/10/2012 12:00:00 AM	ADDRESS	34.09216	-118.28033	title 24 and emergency lighting. one story bldg	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20896	17041-20001-03799	19210 W CALAHAN ST	91324	12	198B121   728	2762017015	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.23636	-118.55078	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20897	11041-10000-15227	11249 N TAMPA AVE	91326	12	210B117    34	2701004013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	ADDRESS	34.27447	-118.55719	REPLACEMENT OF LIGHTING FIXTURES, TO AN EXISTING 7-ELEVEN STORE.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20898	13041-10000-04524	11557 N ENCINO AVE	91344	12	213B129   177	2607011008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.28107	-118.51502	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4KW. NON STANDARD PLAN, TRANSFORMERLESS INVERTER. USING 13 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20899	16041-20000-04619	888 N SARBONNE ROAD	90077	5	141B149   304	4370004049	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	04/18/2023 12:00:00 AM	ADDRESS	34.08649	-118.44979	PLANCHECK FOR A NEW SINGLE FAMILY DWELLING AND GUEST HOUSE.  1600A 120/208V SERVICE WITH 188 KVA GENERATOR BACKUP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20900	19041-20000-23701	13853 W VICTORY BLVD	91401	2	180B153  1054	2238014002	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			06/20/2019 12:00:00 AM	10/20/2023 12:00:00 AM		Issued	10/20/2023 12:00:00 AM	ADDRESS	34.18683	-118.43526	FULL PLAN CHECK, T24 INCLUDED. SCOPE OF WORK INCLUDES NEW 1600A SERVICE, 1600A MDP, A 600A HOUSE PANEL, AND (25) 100A SUB PANELS. 9 TYPICAL UNITS. TOTAL SQUARE FOOTAGE = 30,218 SFB#18010-20000-00913	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20901	18041-10000-27839	700 S FLOWER ST Suite#1950	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI in an existing office area on the 19th floor in Suite #1950.T-24 Energy Only. Bldg Permit: 18016-10000-22165.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20902	15041-10001-31128	4155 W PICO BLVD	90019	10	129B189   891	5081001035	C4-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.04792	-118.32633	((1-20-16: CHANGES MADE TO APPROVED SET. ADDED LOAD AND REVISED LIGHTING. TOTAL LOAD EXCEEDS 400A.))T-24, TI to an existing single story restaurant building (Gus' Fried). Existing Service of 800 amps, adding  new panels, lighting, and receptacles. PC for energy only. SqFt = 3200.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20903	18041-20000-08083	19970 W FRIAR ST	91367	3	180B113   795	2134036007	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.18673	-118.56852	PV1. ROOFMOUNTED SOLAR SYSTEM.SYSTEM SIZE: 9.8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20904	18041-10001-14793	8911-8917 N RESEDA BLVD	91324	12	195B125   400	2770005015	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Public Safety Only			05/24/2018 12:00:00 AM			PC Approved	05/24/2018 12:00:00 AM	ADDRESS	34.23228	-118.53628	05/24/2018CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE RELOCATION OF DEVICES AND FIRE ALARM CONTROL PANELS. _____________PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 65 FA DEVICE, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20905	16041-10002-28680	13439 W BURBANK BLVD	91401	2	174B157   540	2343015018	(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			04/20/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	34.17234	-118.42584	Changes to approved set.  Change inverter type to SMA SB7.0-US (208 Volt).  Addition of string fuses to rooftop junction box.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20906	18041-20000-41525	20851-20853 N SHERMAN WAY	91306	3	183B109    62	2113013038	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Issued	12/14/2018 12:00:00 AM	PIN	34.20136408	-118.5880133	Plan check for power and energy. Scope includes new Service 600A 120/240 single phase 3 wire service. Total area: 810 sq ft. B#17016-20000-03497	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20907	17041-10000-21008	2212 W SUNSET BLVD	90026	13	139-5A207  51	5402029022	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM			PC Info Complete	06/22/2017 12:00:00 AM	ADDRESS	34.07813	-118.26661	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT AND CHANGE OF USE OF (E) FAST FOOD RESTAURANT TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1049 SQ. FT. B# 16016-20000-26363	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20908	15041-10000-28478	7247 N HAYVENHURST AVE UNIT-A1&A10	91406	6	186B137   305	2226001906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Issued	09/04/2015 12:00:00 AM	ADDRESS	34.20296	-118.49362	NEW FIRE ALARM SYSTEM 135 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20909	18041-10000-32289	322 N BROAD AVE	90744	15	027B209    29	7418025021	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.77349	-118.26046	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20910	16041-20000-31394	9301 N OAKDALE AVE #375	91311	12	198B113   113	2761040019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Issued	09/02/2016 12:00:00 AM	ADDRESS	34.23936	-118.56702	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,245 sq. ft.Note: Building permit has been pulled under 16016-10000-18540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20911	17041-10001-33042	6461 N PENFIELD AVE	91367	3	180B113   685	2134038013	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM			Reviewed by Supervisor	09/27/2017 12:00:00 AM	ADDRESS	34.18827	-118.56925	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20912	18041-10001-34818	982 S GRAMERCY PL	90019	4	129B193   182	5081032009	R3-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	12/01/2018 12:00:00 AM	ADDRESS	34.05312	-118.31309	NO PERMIT FEE DUE TO AB1414NEW 6.9 KW ROOF MOUNTED PV SYSTEM WITH 20 AC MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20913	16041-20000-10600	8104 N TROOST AVE	91605	6	189B169    64	2311004030	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.21788	-118.38617	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.59	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20914	15041-10001-06920	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.06326	-118.20213	Plan check hours charged due to initial applicant submittal of wrong set of plans. (((New 5 story Medical Building. Includes Power & Energy and OSHPD  3 PLAN REVIEW.Core & Shell was approved under 14041-10000-29044<<Fee Calcs were provided by applicant with a preprinted check. Fees to be verified during EPC>>)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20915	19041-20000-48457	141 S PLYMOUTH BLVD	90004	4	138B189  1066	5515029020	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.07227	-118.32128	Installation of 27 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20916	11041-20000-23824	21301 W BLACKHAWK ST	91311	12	204B105   834	2706021045	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2011 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Expired	03/05/2014 12:00:00 AM	ADDRESS	34.25899	-118.5954	Plan check roof mounted 8.97KW Enphase Microinverters single family dwelling. Variance to install M215  prior to Test Lab approval has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20917	10041-10001-20893	13455 W MAXELLA AVE Unit # 270	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	"Re-Plan check plans that was expired. First extention filed on 5/30/12. TI of an existing ""AMC Marina 6"" Theatre building.   Plan Check is for Power & Energy.  <<<<Fire Alarm System submitted under 10041-10000-20900>>>>>>Modification to seperate fire alarm has been filed."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20918	17041-10000-44522	643 S VERMONT AVE	90010	10	135B197  1192	5502025006	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	PIN	34.0624111	-118.29203534	Remove HID fixtures and replace with new LED fixtures  T-24 only.TOTAL SQ.FT 7350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20919	16041-20001-00841	5436 N PENFIELD AVE	91364	3	171B113    14	2164003022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.16918	-118.56831	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System is a 3.5 kWac addition onto an existing 2.2 kWac system for a total system of 5.7 kWac. System addition consists of (14) modules, (14) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20920	17041-10000-17189	820 W 8TH ST	90731	15	015B197   536	7454001001	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	33.73709	-118.29554	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20921	17041-10000-10734	430 S BURNSIDE AVE Garage #5-Lot E	90036	4	135B181   198	5509005006	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.06654	-118.35077	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 94,250.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20922	17041-10000-07230	1955 E WASHINGTON BLVD	90021	14	118-5A215   4	5167019045	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.01971	-118.23785	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 365900 SQ FT. INDOOR+ OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20923	11041-20000-19481	16130 W NORDHOFF ST	91343	12	195B141     4	2672001011	(Q)C2-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.23547	-118.48429	T.I.  Existing restaurant. Remodel of their kitchen area and service counter.  Adding less than 400 Amps of new load.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20924	13041-10000-07308	16122 W MORRISON ST	91436	5	168B141   100	2260022005	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	34.16015	-118.48458	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING, TOTAL SYSTEM SIZE 6.86 KW. NEW LOAD CENTER MULTIPLE INVERTER TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. USING TOTAL OF 28 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20925	19041-20000-09817	12339 W HUSTON ST	91607	2	168B165   160	2356026009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.15951	-118.40216	PV1.  Install 10.44 kW DC / 10 kW AC roof mounted grid tied PV system.  (29) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20926	16041-20000-18539	2211 N MARAVILLA DR	90068	4	150B181   123	5549013030	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.11007	-118.34347	PV1.  Install 7.6 kW roof-mounted PV system.  Simplified central inverter standard plan.  (31) modules with (1) 7600 W inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20927	10041-20000-06465	11701 N MASON AVE	91311	12	213B109     9	2701002016	OS-1XL, [T]RE-1, [T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM			PC Approved	04/09/2010 12:00:00 AM				Revisions to 10041-20000-00952ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20928	13041-10000-23524	2049 S CENTURY PARK EAST 2nd floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	09/04/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR TENANT IMPROVEMENT INSIDED OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20929	18041-20001-07606	5839 N CRANER AVE	91601	2	174B173   157	2415002016	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM			PC Approved	03/08/2018 12:00:00 AM	ADDRESS	34.17695	-118.36938	3/8/2018 Changes to an approved set of plans. Changes to downsize system to 10.03 kWdc/7.8 kWac interconnected with msp.(34) modules(34) micro invertersthis is plan check only.   *****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 13.1 kWac and consists of (57) modules, (57) micro-inverters, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20930	14041-20000-30986	17138 W BARNESTON ST	91344	12	216B133   593	2607004010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.2852	-118.50618	pv1central string inverter standard plan system sized 6.0kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20931	18041-10001-47467	2625 W BELLEVUE AVE	90026	13	139-5A205 272	5402009025	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.07595	-118.27338	PLAN CHECK FOR ROOF MOUNTED COMMERCIAL 4.56KVA PV SYSTEM CONSISTING OF 19 PANELS USING MICRO INVERTERS(IQ7-60-US). Plan Check Only.ONLINE PERMIT (PULLED FOR SINGLE FAMILY DWELLING BUT PROPERTY IS COMMERCIAL)Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20932	17041-20001-34470	14331 W JOY DR	91331	6	198B153  1035	2644027247	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24145	-118.44565	Revision to approved set.  Change to higher power module type and inverter rating increased to 3.8 kW AC. (((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20933	19041-20000-44014	14014 W CHAMBERLAIN ST	91340	7	210B153  1121	2616031022	R1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.27284	-118.43856	PV1. INSTALL 5.510 KW DC PV SYSTEM WITH (19) MODULES/OPTIMIZERS AND (1) INVERTER(SE5000)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20934	15041-10001-27170	426 E 58TH ST	90011	9	108B205  1058	5101006006	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	33.98972	-118.26645	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 1000A 480/277 3 PHASE 4 WIRE SERVICE/MAIN DISTRIBUTION BOARD FOR AN EXISTING WAREHOUSE TO  JUICE COMMISSERY MANUFACTURING BUILDING. TOTAL AFFECTED AREA IS 5452 SQ. FT.NOTE: PERMIT PAID UNDER PCIS#15041-10000-27170	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20935	15041-20000-18408	6510 N NAGLE AVE	91401	2	180B157   689	2329025016	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.1887	-118.42348	FEE IS $15.55 DUE TO 2012 STATE SENATE BILL 1222.PV1 SFD. TOTAL SYSTEM SIZE 12.2KW AC USING TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. TOTAL OF 41 MODULES INSTALLED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20936	15041-20001-40314	5022 N WOODLEY AVE	91436	5	168B141    67	2261024011	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.16054	-118.48345	EXPEDITE PER APPLICANT REQUEST.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (53) MODULES-KYOCERA #KU2656ZPA(2)INVERTER-ABB #PVI-6000-OUTD-US-Z-A(1)SUBPANEL 125A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20937	19041-30001-33077	13212 W LOUVRE ST	91331	7	210B157   183	2534007018	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.27366	-118.42056	PC ONLY, INSTALLATION OF A NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND 25 MODULES WITH 25 POWER OPTIMIZERS. TOTAL SYSTEM SIZE IS 6KW. _______________________________________________________________________Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20938	15041-20000-02267	14801 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM			PC Approved	01/26/2015 12:00:00 AM	ADDRESS	34.17768	-118.45513	Install outdoor lighting.  Plan check for energy only.Note: Permint is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20939	13041-10001-16042	9225-9501 S AVIATION BLVD	90045	11	093B173    59	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM			PC Info Complete	05/15/2014 12:00:00 AM	ADDRESS	33.95196	-118.37721	((5/15/2014- CHANGES MADE TO APPROVED SET. ADDED 4 CIRCUITS AND REMOVED GENERATOR. CHANGED COUPLE OF FEEDERS.))pc for power and energy. NEW BUS WASH AND MAINTENANCE BUILDING  7211 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20940	19041-20000-50098	8391 N SAMRA DR	91304	12	192B097   243	2005005021	RS-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.22215	-118.62898	PV1.  Install 9.70602 kW rated solar roof system and 27 kWh energy storage system.  (166) shingle modules and 5.2 and 3.8 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20941	19041-10000-36022	16819 N NORDHOFF ST	91343	12	198B133   615	2687005008	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.2359	-118.49879	Plan check for a PV1 3.8KW AC / 4.8KW DC roof mounted system. Scope includes (1) inverter, (17+2=19) modules and optimizers interconnecting through the main service panel.Orig Permit# 19041-10000-36022 (17 PV modules)Supl Permit# 19041-10001-36022 (2 PV modules)Total of 19 PV Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20942	18041-10000-08924	9055 N RESEDA BLVD	91324	12	198B125   272	2770004005	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Issued	04/03/2018 12:00:00 AM	ADDRESS	34.23509	-118.53635	Plan check for T24 only, replace indoor and outdoor lighting fixtures to LED luminaires with driver. Egress lighting is not part of this scope. Total area: 37,021 sq.ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20943	13041-10006-07125	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			11/23/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.04594	-118.25757	((11-23-2015: SWAPPING SYMBOLS FOR FIXTURE F5 AND F6. PLAN CHECK ONLY APPLICATION))10/28/15Changes to an approved set, changes made to the lighting fixtures, homeruns and manufacturer changed on T-24. (((Change to approved set under field request; All changes are under delta-9 and within the description of the narative letter only.)))(((7-STORY MIXED USED BUILDING 700 UNIT APARMENT, OVER 2-LEVEL SUBTERRANEAN GARAGE :  upper 6 levels residential and retail/gym on the 1st floor. None highrise.. 5000A SERVICE;__this note : by Nabil, this methane zone.  was indicated the level changed from 5 to 2.  see plan number 12041-10000-29828))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20944	16041-10001-01924	11260 W MISSISSIPPI AVE	90025	11	126B153   840	4260001069	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			11/20/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Issued	12/05/2017 12:00:00 AM	ADDRESS	34.03984	-118.44175	Supplemental plan check and permit for changes to approved set of plans noted as Delta-2 - Changes include changing service voltage class from 120/240 to 120/208. Load calculations changes and single line diagram.<<Original plan check #16041-10000-01924Full plan check for a New 3-story, 17-unit apartment building (1200A, 120/240V service) with roof deck over 1-level type I-A parking structure. Total area is 9305 SQ. FT.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20945	18041-20000-35225	8050 N MAMMOTH AVE	91402	6	189B157   126	2213017016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.21777	-118.43195	Plan check for PV roof mounted system and battery storage system. PV system size: 9.6kW AC with 30 PV modules, 30 Microinvertersand 2 battery storage energy Tesla PowerWall 2.0 13.2kWh(2)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20946	10041-20000-22474	20800 W SHERMAN WAY 3RD FLR	91306	3	183B109    78	2137020038	[Q]C1.5-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.00	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.20086	-118.58629	TI ON THE 3RD FLOOR. PLAN CHECK IS FOR POWER AND ENERGY FOR CHANGE OF USE TO MEDICAL OFFICE. NO CHECK FOR OSHPD III	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20947	10041-10000-25764	630 W HARRY BRIDGES BLVD	90744	15	027B205   523	7440015***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM			Verifications in Progress	04/04/2012 12:00:00 AM	ADDRESS	33.77068	-118.26868	NEW PEDESTRIAN BRIDGE FOR PORT OF LA.  EPC IS FOR POWER & ENERGY. (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20948	16041-10000-30787	5638 N FIGUEROA ST	90042	1	151-5A229 278	5468032018	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.10944	-118.19275	T-24, PC FOR ENERGY ONLY. T.I. AND CHANGE OF USE FROM  RETAIL TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1796 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20949	13041-20000-33354	1113 E 27TH ST	90011	9	118-5A209 282	5119011019	[Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.01764	-118.25483	PC FOR T24 ENERGY ONLY PER APPLICANT REQUEST. WORK DONE IN COMMUNITY ROOM. NEW LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20950	19041-10000-41566	445 S FIGUEROA ST 29TH FL	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	Energy plan check for common areas located on the 29th floor of a high rise building. Scope inlcudes new lighting and equipment with a total lighting area of 1,986-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20951	12041-20000-15692	14407 W HAMLIN ST	91401	6	180B149   587	2237014022	[Q]C1-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.00	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.18885	-118.44688	T.I. existing medical building.  Install new subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20952	19041-20000-14253	12137 W MONTAGUE ST	91331	7	204B165    64	2537002017	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	34.25779	-118.39756	PLAN CHECK FOR TI REMODEL OF EXISTING LOW RISE 1-STORY WAREHOUSE AND DETACHED WAREHOUSE BUILDING. REPLACEMENT OF ENTIRE ELECTRICAL SYSTEM, LIGHTS, AND OUTLETS. CHANGE OF SERVICE VOLTAGE CLASS TO 120/208V. T24 INCLUDED, TOTAL AREA = 15,403 SFSERVICE SIZE IS 1600A, INSTALLING 1600A PANEL, 400A PANEL,  AND (2) 25A PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20953	15041-10000-20637	630 W 5TH ST LOBBY	90071	14	130-5A209 151	5151025905	PF-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.05063	-118.25491	TI of (E) retail gift shop and adjoining spaces within the first floor of the LA Central Public Library.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20954	16041-30003-23923	411 S CATALINA ST	90020	10	135B197   557	5502012021	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.06673	-118.29556	02/09/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Power rating of (1) inverter has been reduced to 8.2 kWac, for a total system size of 38.2 kWac. [[[CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. DELTA 1 CHANGES ONLY. CHANGING INVERTER MODEL TO FRONIUS PROMO 10.0 ]]]]$0 permit fee due to State Senate Bill SB 1222PV2.  Install 59.8 kW DC roof-mounted PV system.  (176) modules with (4) 10kW transformerless central inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20955	10041-10001-06588	1149 W 190TH ST	90248	15	060B197   546	7351028018	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	06/17/2010 12:00:00 AM		Permit Finaled	06/30/2010 12:00:00 AM	ADDRESS	33.85848	-118.296	Delta 3 modification only to previously approved set of plans.  See reference notes 7 and 8 on page E0.2, and see new panels on page E0.3 .  A supplemental pertmit is required for the new panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20956	18041-20000-07179	6265 N SEPULVEDA BLVD # 4	91411	6	177B145     9	2242009035	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.18453	-118.46646	Plan check for Title 24 only. Project site is a suite in a multi-tenant building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 1,481 sq. ft.Note: Building application has been generated under 18016-20000-06011	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20957	19041-20000-13877	3026 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20958	17041-20000-04940	7200 N VINELAND AVE	91352	2	183B173    68	2410019037	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.20168	-118.37011	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is lighting within a new packaging room in a bakery. Total lighting area = 1,913 sq. ft.Note: Building application has been generated under 16016-20000-20540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20959	11041-20000-02586	7561 N LANKERSHIM BLVD	91605	6	186B169   277	2317009010	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	ADDRESS	34.20803	-118.38813	New commercial retail center.  New 1200 amp service, panels, and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20960	17041-10000-01229	835 E IMPERIAL HWY	90059	15	087A209   367	6072013022	RD2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	33.93118	-118.25968	NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE = 12.2KVA INCLUDING 2 CENTRAL INVERTERS(SOLIVIA - SOLIVIA 5.2TL & 7.6TL), WITH 50 MODULES(LDK 280P-24).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20961	17041-10000-08467	1420 W 27TH ST	90007	8	123B197  1342	5054032003	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Apartment			03/16/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.03029	-118.29223	PV2. NEW SOLAR SYSTEM FOR AN EXISTING APARTMENT BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 16.0KWdc / 17.92KWac.(64)MODULES-LDK-280P-24 (32)MICROINVERTERS-APSYSTEM YC 500I	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20962	18041-20000-39103	2304 N DONELLA CIR	90077	5	153B145    88	4378020035	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2018 12:00:00 AM			Reviewed by Supervisor	11/27/2018 12:00:00 AM	ADDRESS	34.11602	-118.46315	Plan check for power only. Project site is a new 2-story single-family dwelling with a basement. Work includes an 800-amp service.Note: Building permit has been issued under 16010-10000-01853. Electrical permit fees have been included in the building permit. This is for plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20963	19041-20000-25398	10280 W KURT ST	91342	7	213B177   204	2529006003	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.27697	-118.35372	Plan check for PV roof mounted system, system size: 10.88KW DC, 7.6KW AC with 34 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20964	18041-10000-21232	10250 W SANTA MONICA BLVD # 2390	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	04/24/2024 12:00:00 AM	ADDRESS	34.05949	-118.42045	FIRST TENANT - HONEYMEE- IN COMMERCIAL SPACE WESTFILED CENTURY CITY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20965	13041-20001-34885	5263 N BAKMAN AVE	91601	2	171B173   355	2350017019	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.16663	-118.37756	Change from previously approved plans.  Change include new 800A service, new switchboard, new subpanels, and and new site lighting.  Plan check for power and energy.  All changes indicate by DELTA 1 and 2 on the plans.  Note - Previously approved plans submitted for reference only.*****Previous Description*****Change of used from theater to buddhist center.  Existing 600A service, existing main panel, and existing subpanels.  Install new roof equipment and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20966	19041-10000-36760	1125 E LANZIT AVE	90059	8	088-5A209 144	6071021011	M1-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Issued	09/13/2019 12:00:00 AM	ADDRESS	33.93534	-118.25574	PC for adding a communication panel to an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20967	11041-10000-14289	8500 W BEVERLY BLVD 603	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	tenant improvement inside existing beauty supply store plan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20968	10041-30000-04877	7060 W HOLLYWOOD BLVD 6th FL	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	04/26/2010 12:00:00 AM		Permit Finaled	09/15/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	Plan check T-24 Energy for a TI on 6th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20969	13041-10000-22256	23724 W MIRANDA ST	91367	3	174B093   180	2045024038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.17444	-118.64391	"""Expedited plan check per applicant request"".PV1 10.78KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-3.6-OUTD-US ] [( 44) MOD: TRINA {TSM-245PC05.18}]"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20970	12041-20000-23574	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	New Electric Vehicle Charging Stations in an existing parking structure.  Load is 593 Amps.  Plan check for Power only.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20971	17041-30000-12983	7433 N VAN NUYS BLVD	91405	6	186B149   389	2218004016	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			Verifications in Progress	05/22/2017 12:00:00 AM	ADDRESS	34.20574	-118.44897	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes new distribution equipment and lighting. Total lighting area = 19,795 sq. ft.Note: Building application has been generated under 17016-30000-10082	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20972	17041-20000-38339	879 W 190TH ST 6TH FLR	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	33.85951	-118.28963	Plan check for energy only. TI to entire sixth floor (office) in high rise building. New lighting (incl. emergency) - 19,133sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20973	16041-20000-44723	4441 W SUNSET BLVD	90027	4	147A201   110	5542009016	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.09777	-118.28615	Plan check for power and energy. Change of use of two buildings from office/house/apartments/auto stereo installation to Core and Shell for different restaurant tenant spaces. Connect two buildings with irregular shaped deck. 1-story addition with uncovered outdoor dining on roof. New 2nd floor addition. New elevator, hallway, and mechanical room addition. New uncovered outdoor dining on the first floor, and uncovered dining on the bridge/deck. (N) 2000A service. New lighting ~ T24: indoor- 198sqft; outdoor- 14,969sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20974	12041-10000-08076	1501 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00, 1910.00	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.09822	-118.32695	CHANGE OF USE AND TI OF EXISTING RETAIL TO RETAIL/PHARMACY; PARTITIONS, CEILING, FINISHES; ADD LIQUOR SALE AND OUTDOOR DINING; NEW H/C LIFT, SOFFITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20975	10041-10000-08068	8700 W BEVERLY BLVD #123Q	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.07666	-118.3805	T.I. in existing building (Cedars-Sinai), X-Ray room and bathroom.  Install general and emergency light.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20976	15041-10000-29356	12762 W MUSCATINE ST	91331	6	198B161   241	2629025007	R1-1	North Valley	Sun Valley - La Tuna Canyon			1212.10	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.23987	-118.41143	PV1, INSTALL NEW 6.095 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(23) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20977	14041-10002-06406	20790 W NORDHOFF ST BLDG 2	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM				12-15-2015changes to an approved set of plans, changes include the removal of signage conduits, tenants to install their own. Note changes on delta 8. (((Change to approved set by upgrading the main service equipment from 800-Amp to 2500-Amp with new location. (2) new AV charger stattions and Emergency lighting also added to the plan.All changes are under delta-8 only.(((NEW CORE & SHELL FOR FUTURE COMMERCIAL BLDG. EPC IS FOR POWER & ENERGY. BLDG#14010-10000-00744. This building is designed as a core and shell building only; separate building, electrical, and mechanical permits are required for all future residential unit build-outs or commercial tenant space  build-outs.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20978	12041-10000-30868	539 S WESTERN AVE	90020	4	135B193   798	5503018019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	34.06419	-118.30939	t.i of prevoius retail space. new restaraunt being contrsucted. occupant load less that 49. plan check for t24 and permit. reloacation of existing panel. charged as new panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20979	19041-10000-06794	1837 S FLOWER ST	90015	9	124-5A205 193	5126009013	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM			PC Approved	02/25/2019 12:00:00 AM	ADDRESS	34.03443	-118.27063	T-24, ENERGY ONLY. SCOPE INCLUDES NEW EXTERIOR LIGHTING FOR AN EXISTING COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS 4770 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20980	13041-20000-20783	533 S FREMONT AVE	90071	14	130-5A209  67	5151021010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Issued	08/15/2013 12:00:00 AM	ADDRESS	34.05205	-118.2589	FIRE ALARM SYSTEM REPLAING ADDING 2 PANELS AND 425 NEW DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20981	16041-10001-01369	710 W HARRY BRIDGES BLVD	90744	15	027B205   665	7440007901	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	ADDRESS	33.7693	-118.27062	Changes to approved set.  Relocate methane control panel to electrical room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20982	14041-20000-26889	21300 W VICTORY BLVD SUITE 210	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.18813	-118.59618	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING SUITE 210.  EXISTING POWER EQUIPMENT TO BE USED.  NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20983	15041-10000-17760	20700 W SESNON BLVD	91326	12	219B109     5	2701001040	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Issued	08/10/2015 12:00:00 AM	ADDRESS	34.29545	-118.58467	PLAN CHECK FOR T24 ENERGY HOA OUTDOOR STREET LIGHTING FOR TRACT NO. 50507-01.TOTAL SAQUARE FOOTAGE 163,664.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20984	17041-10001-29581	22404 W ITASCA ST	91311	12	201B101   532	2727001012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.24427	-118.61503	Supplemental for expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20985	11041-10001-11468	451 S HEWITT ST	90013	14	127-5A215 370	5163022019	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM			PC Approved	09/15/2011 12:00:00 AM	ADDRESS	34.0421	-118.23525	Delta 3 modification to comply with inspectors correction notice of  August 29, 2011.  CHANGE OF USE FROM AN OFFICE BUILDING TO A COFFEE ROASTING PLANT.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20986	19041-10000-16176	963 E 4TH ST 3rd Floor	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.04337	-118.23442	T-24, PC for any Energy only. Change of use from retail to office on the 3rd floor. Installing new LED lights. Total area 31779 SF.Building Permit:: 19016-40000-11061	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
20987	14041-10000-20089	542 N HIGHLAND AVE	90004	4	141B185   843	5524025002	R1-1-HPOZ	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Expired	09/29/2016 12:00:00 AM	PIN	34.08156439	-118.33820662	PV1 ROOF MOUNTED MICORINVERTER SYSTEM. TOTAL SYSTEM SIZE 5KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
20988	16041-20000-10139	12423 N GLADSTONE AVE #26	91342	7	219B161   251	2525018057	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	34.29571	-118.4121	Plan check for energy only. TI to existing commercial building. New lighting (incl. emergency). 2,300sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20989	14041-20000-06898	16427 W SAN JOSE ST	91344	12	207B137   772	2679005034	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	PIN	34.26127747	-118.49014442	pv1 single family dwelling. total system size 3.8kw ac using transformerless inverter. using power optimizers. nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20990	15041-20001-24374	18340 W VANOWEN ST	91335	3	180B125    42	2125016018	[Q]C2-1L-CDO-RIO, [Q]P-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.19365	-118.5331	Revisions to approved set.  Change to architectural details, change of fixtures from fluorescent to LED.  MIscellaneous revisions.  Plan check for power and energy.  Approval for delta-1 revisions only.  (((PLANCHECK FOR POWER AND ENERGY. T. I. TO (E) RETAIL.  DD'S. DISCOUNT STORE. 24000SQFT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20991	18041-10000-13944	12800 W CHANDLER BLVD	91607	2	171B161   133	2346021049	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Issued	04/17/2018 12:00:00 AM	ADDRESS	34.16818	-118.41161	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20992	16041-10000-16687	4151 W PROSPECT AVE 1ST FLR	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE GROUND FLOOR PLAZA. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2939 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20993	14041-20001-28215	11620 W WILSHIRE BLVD	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	3/3/2015 Changes to an approved set of plans. Changes include the change of the lighting control system and change of manufacturer for (1) light fixture. All changes have been clouded and labeled Delta 4.*****Previous Work Description*****Plan check for energy only. TI/change of use to 1st floor of existing ~10 story high rise building. Yoga studio with new lighting (incl emergency). 5,350sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20994	13041-20001-15074	4140 S GLENCOE AVE 1-67	90292	11	108B153  1141	4230006006	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			01/28/2015 12:00:00 AM			PC Approved	07/31/2015 12:00:00 AM	ADDRESS	33.98897	-118.4417	[[[[1/28/15  CHANGES TO APPROVED SET. REMOVING COMMERCIAL UNITS AND REDUCING RESIDENTIAL TO 67 UNITS. FLOOR LAYOUTS FOR ALL UNITS CHANGED. ALSO CHANGES TO COMMON AREAS. ALL CHANGES ARE CLOUDED. ]]]]NEW CONSTRUCTION OF 69 UNIT APARTMENT COMPLEX. FIRE ALARM VARIANCE HAS BEEN FILED. PLAN CHECK FOR POWER AND ENERGY. NONHAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20995	17041-10001-06220	8854 W THRASHER AVE	90069	4	147B169   478	5561025004	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.09898	-118.3856	"PC FOR REVISIONS TO APPROVED SET. SCOPE INCLUDES CHANGES TO PANEL ""C"" LOADING. ADDED WATER HEATER AND ADDITIONAL CIRCUIT. B# 14014-10000-02323"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20996	10041-10000-02530	8320 W MELROSE AVE	90048	5	141B173   485	5528015028	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM	03/12/2010 12:00:00 AM		Permit Finaled	12/10/2010 12:00:00 AM	PIN	34.0833936	-118.37106779	Title 24, energy for two story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
20997	17041-20001-24662	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.04338	-118.26581	PLANCHECK ONLY. Installation of (5) roof-mounted 36 kVA-rated dehumidifier units per inspection correction notice.  Plan check for power - load exceeds 400 A. PERMIT UNDER 17041-20000-24662.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
20998	17041-10000-01899	6670 W 85TH PL	90045	11	096B161   591	4112029018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM			Reviewed by Supervisor	02/01/2017 12:00:00 AM	ADDRESS	33.96029	-118.40688	PV INSTALLTION OF 5.67 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.  WITH BATERY BACK UP. (18) MODULES:LG LG315N1C-Z4(1) SOLARCITY DELTA H6	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
20999	12041-20000-14584	14121 W VENTURA BLVD	91423	5	165B153   388	2265020006	(T)(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Closed	06/05/2013 12:00:00 AM	ADDRESS	34.14982	-118.44087	Fire alarm sysstem for 113 UNITS, 4-STORY  apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21000	16041-10004-12885	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.21922	-118.44896	DELTA 1 REVISIONS TO PERMITTED SET OF PLANS:  IN DWELLING UNITS RECEPTECACLES REARRANGED AND TYPES OF LUMAIRES CHANGED. ALL CHANGES ARE CLOUDED((((((ADAPTIVE REUSE OF EXISTING 13 STORY COMMERCIAL BUILDING CONVERTED INTO 192 RESIDENTIAL UNITS. (2) services: 3000A, 4000A. (7) Typical units. Total common area: 37,706 sq.ft.  Fire alarm variance has been completed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21001	19041-10000-21498	12359 N TWILIGHT AVE	91342	7	219B149   886	2507009075	(Q)RD3-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Issued	06/06/2019 12:00:00 AM	ADDRESS	34.29477	-118.44999	PV1 roof mounted, Scope of work includes 15 modules(Q-peak 285) ,optimizers (SE P320), with a central inverter (SE3800H-US). System size is 3.8KWac/4.275KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21002	19041-30000-16264	7217 N CORBIN AVE	91306	3	183B117    23	2115019020	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.20168	-118.56243	1200A 208Y/120V 3ph-4w service, distribution, power, and lighting for commercial building.  Note: Building application has been generated under 18016-20000-36898	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21003	16041-20000-03994	11870 N COMETA AVE	91331	7	216B161   485	2527009017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.28614	-118.41191	Plan check for PV roof mounted system. System size: 3.0kW with 13 modules and 1 inverter(3.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21004	14041-20000-11075	7900 N BALBOA BLVD BLDG N	91406	6	189B133   403	2205006902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.21347	-118.50092	PC FOR NEW SERVICE. BUILDING N. NEW 800A. ALL LOADS FUTURE. THIS IS PLAN CHECK FOR SERVICE ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21005	18041-20000-38894	8444 N COLUMBUS AVE 1-25	91343	6	192B145   255	2654025044	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Apartment			10/11/2018 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	01/25/2022 12:00:00 AM	ADDRESS	34.22412	-118.46536	Plan check for power and energy for multi residential building 25 units 4 story building. New 1200A 120/208V 3 phase 4 wire service.  Total area: 24,313 sq ft. B#18010-20000-01220	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21006	14041-20000-21809	19336 W VISTA GRANDE WAY	91326	12	216B117    62	2872002021	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.2889	-118.5543	PV1Central Transformerless Inverter standard plan.Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 6kW(2) PowerOne PVI-3.0-OUTD-S-US-A transformerless inverter(30) REC Solar REC260PE(BLK) pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21007	16041-10001-08253	18816 W SAN FERNANDO MISSION BLVD	91326	12	210B121   184	2717006013	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM			PC Approved	04/08/2016 12:00:00 AM	ADDRESS	34.2734	-118.54293	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND A LOAD CENTER. (46) MODULES, (1)INVERTER-7.7KW, AND (1) INVERTER-5KW. TOTAL SIZE IS 12.7 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21008	13041-10000-35487	617 W 7TH ST 304	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.04779	-118.2571	PLAN CHECK FOR T24 ENERGY (EMERGENCY LIGHTS AND EXIT SIGNS) PER INSPECTORS REQUEST. TENANT IMPROVEMENT. OFFICES. HIGHRISE. 3RD FLOOR SUITE 304. 4208SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 13041-90000-34685	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21009	13041-10001-34518	6206 N BABCOCK AVE	91606	2	177B161   388	2332017002	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.18329	-118.4062	Expedited RSES plan check per applicant request.{{PV1, Install  4.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (17) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21010	18041-10000-24710	7558 N RESEDA BLVD	91335	3	186B125   264	2119017029	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.20792	-118.53585	TITLE 24 ONLY FOR THE REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21011	17041-10002-44638	3315 W 41ST ST	90008	10	114B185   300	5024028027	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.01015	-118.33021	"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA ""C"". CHANGES INCLUDE INTERCONNECTING PV BATTERY BACK UP TO THE MAIN SERVICE. REPLACING 100A PANELBOARD WITH AN ATS PANELBOARD AND INSTALLING A 25A ATS BREAKER.-Portion of the permit fee is paid under 17041-10000-44638."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21012	19041-30000-52142	3215-3223 S LA CIENEGA AVE	90232	10	123B173  2129	4312022029	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	02/10/2020 12:00:00 AM		Permit Finaled	01/27/2023 12:00:00 AM	ADDRESS	34.03181	-118.37901	PLAN CHECK FOR ENERGY ONLY SCOPE OF WORK IS LIGHTING FOR A CORE AND SHELL SPACE ONLY, ANY FUTURE TI TO BE SUBMIITED SEPRATELY. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 23,649 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21013	14041-10000-06137	13455 W MAXELLA AVE #206-114	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	33.9867	-118.44159	PLAN CHECK FOR T24 ENERGY FOR WELLS FARGO BANK. 2 STORY BUILDING. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. 4044 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21014	17041-20000-40108	17512 W CORINTHIAN DR	91316	5	168B129   461	2290012028	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.15687	-118.51466	permit fee $3.97 by state senate bill no.1222pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21015	16041-10000-42022	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	PIN	33.92817449	-118.43220714	PLAN CHECK FOR POWER ONLY, HYPERION WATER TREATMENT PLANT.  ADDING 3 NEW 300HP  AND 3 NEW 75HP MOTOR TO  DISTRIBUTION BOARD LVS-116.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21016	12041-10000-08697	378 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Expired	12/03/2014 12:00:00 AM	ADDRESS	33.93089	-118.26662	PLAN CHECK NEW 20.5KW ROOF MOUNTED AND GROUND MOUNTED PHOTOVOLTAIC SYSTEM FOR APARTMENT BUILDING. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21017	11041-20000-08200	13949 W VENTURA BLVD	91423	5	165B153   438	2271014006	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.14916	-118.43708	T.I. to existing building.  Install general/emergency lighting.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21018	17041-10000-20930	23872 W FRIAR ST	91367	3	177B089    35	2033018001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.18522	-118.64627	PC FOR ROOF MOUNTED PV SHINGLES. TOTAL SIZE 9KW AC USING 2 CENTRAL INVERTERS. ZONING COVERED UNDER BUILDING PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21019	16041-20001-33327	13801 W VENTURA BLVD	91423	4	165B153   543	2271017005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	34.14852	-118.43319	expedite per applicantpv2install roof mounted pv system sized 22kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21020	16041-20000-32269	16509 W SATICOY ST 2nd Floor	91406	6	186B137    25	2205009054	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Issued	09/12/2016 12:00:00 AM	ADDRESS	34.20857	-118.49267	Plan check for Title 24 only. Project site is an existing commercial 2-story building. Project scope is a tenant improvement to the 2nd floor. Total lighting area = 2,875 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21021	16041-20000-14601	1541 S ORANGE GROVE AVE 1-8	90019	10	129B173  1002	5068023006	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.04835	-118.36655	Fire alarm plan check only. Install a new fire alarm system in an 8-unit, 4-story apartment over basement garage. FACP+70units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21022	15041-20001-01844	416 W 8TH ST	90014	14	127-5A209  58	5144018030	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.04471	-118.25646	Changed to approved set. Changed on mechanical equipments and lighting floor plan. PC only. Permit under 15041-20000-01844. ((High rise 13 stories. Adaptive reuse to hotel.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21023	18041-10000-32509	3777 N CAHUENGA BLVD	91604	4	162B177   445	2425002011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM			PC Approved	08/24/2018 12:00:00 AM	ADDRESS	34.13647	-118.36286	Energy plan check for a FIRE DAMGE REPAIR. Scope includes new lighting and equipment with a total Title-24 area of 7580-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21024	16041-10000-20848	1149 S HILL ST #750	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	PC for T-24 only. Tenant improvement on a portion of the 7th floor, 8,558 sq ft.B# 16016-10000-12833	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21025	14041-10001-26651	16542 W VENTURA BLVD Unit 120	91436	5	168B137   369	2284005025	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.1576	-118.49393	Change to an approved set, all changes apply to delta-3 only.(((Full plan check. Medical office. Building application number 14016-10000-19503. TI  to convert commercial office to medical space in existing 5 story building. Installing new lighting, power, and communication systems. Fire alarm to be submitted separately.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21026	19041-10000-24723	601 S FIGUEROA ST 8-9th Flrs	90017	14	130-5A209 175	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.05076	-118.25881	PC for T24 only for a TI in a office building high rise. The scope of work is new lighting in the 8th floor, and the 9th floor. Total affected area for 8th floor is 636 sqft and total affected area for 9th floor is 17881 sqft. B# : 19016-10000-16106	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21027	17041-10000-08634	6611 N HASKELL AVE	91406	6	180B141   296	2233002035	RD1.5-1-RIO, [Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.19091	-118.47518	PC for energy only, outdoor. Removing HID fixutres and replacing them with New LED ones. Area: 19220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21028	17041-10000-13159	606 N BONNIE BRAE ST	90026	13	138A207   192	5404010017	RD1.5-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.07222	-118.2642	Installation of new roof mounted solar PV array on existing single family dwelling with 5.8 kVA battery backup.  Central inverter system.  Total system size = 3 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21029	19041-10000-02785	2618 S LA BREA AVE	90016	10	123B181  1167	5049004019	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.03177	-118.3511	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21030	17041-10000-39640	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	08/23/2021 12:00:00 AM	ADDRESS	33.94571	-118.38857	Full for power and energy. Addition to an existing 13-story office building.  Change of use to  a 401 gustroom  hotel with amenities. Scope includes new panels, new generator, fire pump, and circuits. Total affected area is 261,000 sq. ft (Indoor and Outdoor).B#16016-10000-29872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21031	18041-10000-15244	2861 W AVENUE 35	90065	1	154-5A215 253	5457026011	[Q]CM-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Closed	11/02/2018 12:00:00 AM	ADDRESS	34.11628	-118.23614	T-24 PLAN CHECK FOR ENERGY ONLY, T. I. & CHANGE OF USE TO DANCE STUDIO. TOTAL SQ. FT.1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21032	16041-10000-09173	501 W EL SEGUNDO BLVD	90248	15	081B201   259	6132002024	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	33.91659	-118.28337	FULL PC FOR A FIRST TIME TENANT, LITTLE CAESARS RESTAURANT. SCOPE OF WORK INCLUDES A NEW PANEL, NEW LIGHTING AND RECEPTACLES.  TOTAL SQ. FT. 926.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21033	19041-10000-36257	7120 N VASSAR AVE	91303	3	183B105   319	2111024016	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.19987	-118.60421	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21034	14041-10000-24379	5322 N NEAL DR	90041	14	163-5A223  64	5671007017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.14332	-118.21296	Installation of roof mounted solar PV array.  Total system size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21035	15041-20000-02615	916 N WESTERN AVE	90029	13	141B193    34	5535020009	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.08674	-118.30896	PC FOR T24 ENERGY ONLY. NEW LIGHITNG. TI TO OFFICE SPACE. LOW ADDITIONAL LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21036	18041-20000-48554	9733 N TOPANGA CANYON BLVD	91311	12	201B101   839	2727023003	[Q]CR-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.24693	-118.60718	Lounge and leasing office remodel.  New ornamental lighting - Title 24 plan review.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21037	13041-20000-15412	333 S HOPE ST 10th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	T24 FOR HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON THE 10TH FLOOR ELEVATOR LOBBY. 490 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21038	19041-10000-43466	11111 W SANTA MONICA BLVD Suite#1100	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.04771	-118.44481	TI IN AN EXISTING OFFICE/COMMERCIAL AREA IN SUITE #1100. Installing new lights. T-24 Energy Only. Affected area: 7640 SFT.(((Bldg Permit# 19016-10000-33232)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21039	19041-20000-41390	11825 W TERRA VISTA WAY #138	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21040	13041-20000-18111	1507 S LOUELLA AVE	90291	11	114B149   936	4244017008	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.00563	-118.45618	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.4 KW. USING TRANSFORMERLESS INVERTER. 14 MODULES. 2 STRINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21041	14041-10000-17332	1130 S HOPE ST	90015	14	126A207    23	5139021004	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Corrections Issued	11/14/2014 12:00:00 AM	ADDRESS	34.04139	-118.26363	10-story hotel with restaurant, club lounge, pool deck and conference/meeting room - Major alteration & addition to an (E) URM building . Site in Methane zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21042	17041-10001-20864	650 W 35TH ST 4th floor	90089	9	120A201    96	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.02162	-118.2827	REVISED LIGHTING PLAN AND TITLE 24 COMPLIANCE FORMS TO INCLUDE NEW LIGHTING IN THE LOBBY AND CHANGES TO TYPES OF LUMINAIRES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21043	15041-20000-11273	1564 W 45TH ST	90062	8	111B193   301	5016008007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.00269	-118.30558	Installation of new roof mounted solar PV array.  Total system size = 6.12 kWac.  Microinverter system with two branch circuits.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21044	14041-10000-22795	2624 E LANCASTER AVE	90033	14	133-5A227 242	5202011007	RD2-1	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Apartment			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.05805	-118.19753	PV1. ROOF MOUNTED SOLAR SYSTEM. UNGROUNDED. SYSTEM SIZE: 1.53 KW. (6) KYOCERA  KD255 MODULES(1) ABB PVI 3.0 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21045	19041-10000-34370	5441 W 104TH ST	90045	11	090B173   264	4129033004	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	33.94208	-118.37581	NEW FIRE ALARM SYSTEM WITH SPRINKLER MONITERING. SCOPE INCLUDES NEW FA PANEL AND 25 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21046	10041-10000-13228	10250 W SANTA MONICA BLVD # 26	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	12/15/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE. Existing service and panels, New circuits. Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21047	11041-10000-20685	1072-1076 E ELKGROVE AVE BLDG 21	90291	11	111B145   308	4243001037	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.00259	-118.45935	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21048	15041-10000-29072	1120 S GRAND AVE	90015	14	126A207    60	5139020024	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			09/03/2015 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	03/15/2019 12:00:00 AM	ADDRESS	34.04095	-118.26231	New 41 story apartement  building, 536 units. PC for Power and Energy. FA variance on file.Building app. under 13010-10000-03761 architect to update building submittal at a later time.**Ref. : Additional Plan check noted as Delta-6 under 15041-10001-29072	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21049	16041-10000-00186	11616 W BLIX ST	91602	2	168B169   612	2354017008	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	03/05/2016 12:00:00 AM	ADDRESS	34.15657	-118.38612	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.  (45) REC SOLAR 275 MODULES(45) OPTIMIZERS(1) SOLAREDGE 11400 WATT INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21050	16041-10000-23235	2030 W 8TH ST	90057	1	132A203   260	5141020017	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.05466	-118.27766	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING  COMMERCIAL BUILDING (7 ELEVEN).SCOPE INCLUDES NEW PANELS NEW RECEPTACLES AND NEW LIGHTS. TOTAL EFFECTED AREA IS 4175 SQFT (INDOOR AND OUTDOOR).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21051	15041-20001-30065	1249 S BUNDY DR 1-18	90025	11	126B145   321	4263002022	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			09/11/2015 12:00:00 AM			PC Approved	11/05/2015 12:00:00 AM	ADDRESS	34.04292	-118.46644	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21052	19041-10000-07868	20929 W VENTURA BLVD UNIT 14	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTS AND EXIT SIGN TO VACANT RETAIL SPACE PLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21053	19041-20000-26479	5910 W SUNSET BLVD	90028	13	147A191    82	5545015001	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	10/30/2020 12:00:00 AM	ADDRESS	34.09787	-118.31847	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,895 sq. ft.Note: Building application has been generated under 19016-20000-21053	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21054	18041-10000-39049	214 S WESTMORELAND AVE	90004	13	135B197    84	5501020014	R3-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Apartment			10/11/2018 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.0698	-118.28773	Full plan check for 800-Amp service 120/240v 3- phase 4-wire with new panels, equipments total affected area 8020-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21055	19041-20000-10406	5440 N GENESTA AVE	91316	5	174B133   736	2258027010	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.17029	-118.50367	pv1install roof mounted pv system sized 7.6KW AC with battery 5KW interconnetced with msp.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21056	15041-10000-31170	6330 W SAN VICENTE BLVD STE 510 &-520	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.06116	-118.36804	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING(OFFICE). SCOPE INCLUDES NEW LIGHTING ON 5TH FLOOR. TOTAL AREA IS 2820 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21057	14041-20000-24801	7000 S HOOVER ST Unit #6	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #6.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21058	17041-10000-20044	10011 W CHEVIOT DR	90064	5	123B165   225	4316015006	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	02/09/2019 12:00:00 AM	ADDRESS	34.03578	-118.40305	Installation of new energy storage system.  New 200 amp load center and Tesla AC Powerwall 5.8 kVA 13 kWH battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21059	14041-10000-04948	1624 W 7TH ST	90732	15	015B193   172	7559033015	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Expired	04/19/2016 12:00:00 AM	ADDRESS	33.73837	-118.31278	PV1, INSTALL 8.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(33) MODULES: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21060	13041-10000-26514	10201 W PICO BLVD bldg100-5thfloor	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	PIN	34.05182951	-118.41257696	TITLE 24 PLAN CHECK ONLY. NEW LOAD UNDER 400 AMPS. 5 STORY BUILDING. BUILDING 100.  30137 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.Permit under inspection fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21061	13041-10002-16314	401 WORLD WAY	90045	11	090B161    37	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM			PC Approved	05/13/2015 12:00:00 AM	ADDRESS	33.94281	-118.40686	T24, plan check only. Change to an approved set, 13041-10000-16314 . supplemental is to account for the additional outdoor lighting on roof top parking lot.  Total additional outdoor lighting area is 71,901-sq ft. Whole packege of the plan should be stamped;  permit should be pulled under original application.All changes apply to delta-2 and 3 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21062	10041-10000-20008	747 S WAREHOUSE ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	04/13/2012 12:00:00 AM		Issued	04/13/2012 12:00:00 AM	ADDRESS	34.03468	-118.23965	NEW 600 AMP 4600 V SECTION FOR A FACTORY BUILDING. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21063	14041-20000-07003	6310 N BERTRAND AVE	91335	5	177B129  1103	2123022058	R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	PIN	34.18431295	-118.52411166	PV1 ROOFTOP MICROINVERTER. TOTAL SYSTEM SIZE 2.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21064	18041-10001-40482	6600 N TOPANGA CANYON BLVD SPC 49A-&B	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	DELTA 5 CHANGES TO AN APPROVED SET. ADDITION OF 1 NEW CIRCUIT FOR WALL DISPLAY, UPDATING OCPD SIZES FOR AHU1 AND 2. SCOPE ALSO INCLUDES CHANGES TO FLOOR PLANS BASED ON SITE CONDITIONS. (LIGHTING, RECEPTACLES AND CONTROLS). nO CHANGES TO T-24 FORMS FOR INDOOR LIGHTING.  Original Scope: PLAN CHECK FOR TITLE 24 ONLY. CHANGE OF USE FROM RETAIL TO RETAIL. NEW TENANT SPACE, ALL (E) ELECTRICAL AND SYSTEMS TO BE REMOVED AND NEW ELECTRICAL IS TO BE INSTALLED.building permit #18016-10000-32575*T.I. FOR CONSTRUCTION OF NEW NON LOAD BEARING WALLS; NEW MALL STOREFRONT; NEW FLOORING FINISHES; NEW FURNITURE AND FIXTURES; NEW OD OFFICE EQUIPMENT.*	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21065	18041-10000-29640	6751 N LOUISE AVE	91406	6	180B133    35	2229008900	[Q]PF-1XL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.19341	-118.51001	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21066	19041-20000-23857	10247 N VARIEL AVE	91311	12	204B105   375	2747005022	(T)P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Apartment			06/21/2019 12:00:00 AM	07/20/2020 12:00:00 AM		Permit Finaled	02/11/2022 12:00:00 AM	ADDRESS	34.25672	-118.59307	1200A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21067	18041-20000-14939	1255 N BEACHWOOD DR	90038	13	144B189   151	5534015004	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			04/24/2018 12:00:00 AM			PC Info Complete	12/16/2019 12:00:00 AM	ADDRESS	34.09405	-118.32132	600A 240/120V 3ph-4w service, distribution, power, and lighting for new construction.  Building permit under 18010-20000-00489.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21068	14041-20000-12086	19200 W LASSEN ST	91324	12	201B121   161	2762003026	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.24973	-118.55147	Note: Permit is $0.00 due Senate Bill 1222 from 2012.PV1Install roof-mounted solar array on SFD. System size: 11.73kW(2) SolarEdge #SE5000A-US-ZB-U transformerless inverters(46) Trina Solar #TSM-255PA05.18 pv modules(46) power optimizers (1) Load center 125Amp	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21069	19041-20000-08494	6613 N FAIR AVE	91606	2	180B173   457	2319012006	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	PIN	34.19068553	-118.37495325	PV1.  Install 1.65 kW roof mounted grid tied PV system.  (6) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21070	14041-20002-20609	1636 W 8TH ST	90017	1	130-5A205 112	5142017021	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.05263	-118.27317	PC FOR CHANGE OF INTERCONNECTION DESIGN. NEW DISTRIBUTION HAS BEEN ADDED UNDER SEPARATE PERMITS. THIS PLAN CHECK IS TO VERIFY SOLAR BACKFEED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21071	15041-10000-14886	1200 S BROADWAY	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/15/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.03792	-118.26026	(N) 7-story mixed use 177 unit apartment building with 2 levels of basement parking garage.  (2) 3000A 120/208 services.Fire alarm variance filed 05/15/2015.Building permit was submitted prior to July 1, 2014 - 2008 Energy Code	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21072	16041-30000-03740	14006 W RIVERSIDE DR Space 68 &-70	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Title 24 plan check only.  Total area = 3,421 sq. ft.    T.I. to existing retail space at mall.  Relocating two subpanels and transformer.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21073	11041-20000-21707	8635 W 3RD ST #580	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.07373	-118.38073	Medical office t.i.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21074	18041-10001-33066	13121 N PORTOLA WAY	91342	7	225B165    19	2580018***	RD6-1XL	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Issued	10/19/2018 12:00:00 AM	ADDRESS	34.31104	-118.40531	Change to approved set to add 100A load center, design and system size remain the same. ((Plan check for PV roof mounted system, system size: 5.76kW AC with 18 pv modules and 18 microinverters))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21075	15041-20001-39531	15303 W VENTURA BLVD P36	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.15413	-118.46661	06-13-2016 Changes to an approved set of plans. Changes include relocate dimmer switches and keep existing lighting fixture B and different manufacturer for lighting fixture  C{{{{{{T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (NAIL SALON, UNIT P36). SCOPE INCLUDES ADDING NEW LIGHTS TO PANEL 'A'.   }}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21076	12041-20000-16635	6363 W SELMA AVE	90028	13	148-5A187 313	5546008010	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM			Reviewed by Supervisor	08/09/2012 12:00:00 AM	ADDRESS	34.09989	-118.32893	New recording studio.  Power and energy plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21077	18041-10000-09764	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Closed	07/20/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	Full plan check for first time tenant (office space). Install new feeders to the tenant space with (4) new panels, (2) transformers, new lightings and power. Total area: 13,832 sq.ftTHIS IS DESIGNED BUILD PROJECT. (no building application submitted at the moment per applicant, electrical core & shell under 16041-10000-28773)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21078	10041-20000-25687	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			01/03/2011 12:00:00 AM			Verifications in Progress	03/16/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	Stage 18 electrical upgrade.  Install new switchboards, subpanels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21079	11041-10000-10091	4547 W BRAZIL ST	90039	4	165B201   209	5593010018	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	03/19/2012 12:00:00 AM	ADDRESS	34.14693	-118.27407	Install new fire alarm, 10 devices and one panel. single story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21080	10041-10000-03914	21441 W OSBORNE ST	91304	12	195B105    38	2779018035	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.23378	-118.599	plan check fire sprinkler monitoring sysem for single story bldg. two panels and 5 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21081	17041-10001-28780	4214 S SUTRO AVE	90008	10	114B189  1238	5023027011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.00666	-118.32292	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21082	14041-10000-27661	2541 N ABERDEEN AVE	90027	4	153B197    71	5588029027	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.11654	-118.28893	PV1. ROOFMOUNTED CENTRAL INVERTER STANDARD PLAN. SYSTEM SIZE: 6 KW .(30) KYOCERA KD255 MODULES(1) ABB PVI-6000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21083	19041-10000-07566	1111 S BROADWAY	90015	14	126A209   139	5139019035	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	09/03/2021 12:00:00 AM	ADDRESS	34.03943	-118.25948	NEW FIRE ALARM IN AN EXISTING 5 STORY MIXED USE HISTORIC BUILDING. SCOPE INCLUDES NEW FACP AND 280 DEVICES.B#16016-10000-19257	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21084	18041-10000-17369	8500 W BEVERLY BLVD 718A	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR T-24 ENERGY ONLY FOR AN EXISTING RETAIL SPACE. SCOPE INCLUDES NEW PANEL, CIRCUITS, EQUIPMENTS, TRANSFORMER AND LIGHTING. TOTAL AFFECTED AREA IS 750 SQ.FTB#18016-10000-13892	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21085	10041-10000-06147	8000 W SUNSET BLVD 1st level	90046	5	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	08/25/2010 12:00:00 AM	ADDRESS	34.09783	-118.36466	T.I. for a salon space.  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21086	14041-10001-01509	5128 N BLUEBELL AVE	91607	2	171B161   692	2357002010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			Verifications in Progress	05/21/2014 12:00:00 AM	ADDRESS	34.16372	-118.41036	Expedited RSES plan check per applicant request.{{PV1, Install 12.5 kW DC roof-mounted solar array for a  two story house, interconnect with main service panel. Negatively grounded system. (1) Transformered inverters: Fronius IG PLUS V 10.0 (50) Modules: SOLAR TSM-250P A05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21087	15041-10000-22689	1149 S HILL ST 1ST FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.03926	-118.26099	ALTERATIONS IN A CONFERENCE ROOMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21088	10041-20000-24485	1328 W MORNINGSIDE WAY	90291	11	114B149  1014	4244020031	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	PIN	34.00494592	-118.4549333	PLAN CHECK FOR ROOF MOUNTED 14.85KW PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21089	19041-10000-35612	2062 E 99TH PL	90002	15	093A217   176	6046019930	OS(UV), R3(UV), RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/21/2019 12:00:00 AM	05/26/2020 12:00:00 AM		Permit Finaled	04/11/2022 12:00:00 AM	ADDRESS	33.94667	-118.23556	Full plan check for a new 3000-AM 120/208v 3-phase service. Scope inlcude new lighting and equipment with a total lighting area of 80,902-SQ FT.((((per building application,  Proposed 5-story apartment building with 80 units. 4-stories type V-A construction over 1-story type I-A. AREA OF SCOPE (80902 SF). BUILDING PERMIT # : 19010-10000-02683)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21090	16041-20000-29954	415 E MANITOBA ST	90293	11	093B153   117	4117030017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	33.95337	-118.44194	BATTERY STORAGE SYSTEM. SYSTEM SIZE: 500 WATTS.  PV1. ROOFMOUNTED SOLAR SYSTEM. 2 SUNSPARK SMX-250P MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21091	19041-30000-17454	17320 W VENTURA BLVD	91316	5	168B133    18	2290001002	QC4-1VL, QP-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.16078	-118.51069	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/addition of lighting to sales floor. Total lighting area = 15,318 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21092	12041-20000-23125	22959 W CALIFA ST	91367	3	177B097   587	2041019016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.17749	-118.62736	new single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21093	11041-10000-10786	555 S FLOWER ST 3rd & 6th-Floors	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM			PC Approved	05/25/2011 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI TO AN EXISTING 54-STORY OFFICE BUILDING.  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK ONLY.  WORK IS ON 3RD AND 6TH FLOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21094	15041-10000-35851	11150 W OLYMPIC BLVD 7th Flr	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.03956	-118.43857	Energy plan check for an office T.I located in the7th floor of a high rise building. Scope includes new lighting and receptacle for restroom, corridor and the elevator lobby; Total areaa is 1738-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21095	10041-10000-02151	2410 N LILLYVALE AVE	90032	14	139-5A237 104	5220034025	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM	03/05/2010 12:00:00 AM		Permit Finaled	05/20/2010 12:00:00 AM	ADDRESS	34.07504	-118.16432	Plan check T-24 energy outdoor lighting for Grifols parking lot.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21096	17041-20001-31073	5738 N OAKDALE AVE	91367	3	174B113   152	2153018019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.17554	-118.56553	expeditepv1install roof mounted pv system sized 12kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21097	10041-10000-08107	3239 E UNION PACIFIC AVE	90023	14	118-5A223 219	5169001022	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	05/26/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	34.01679	-118.20972	TI IN AN EXISTING COMMERCIAL AREA. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS AND EMERGENCY LIGHTS. COMPLETE ELECTRICAL PLAN CHECK MAY BE REQUIRED, SUBJECT TO FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21098	14041-20000-02453	6102 N RESEDA BLVD	91335	3	177B125   614	2124008025	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.18093	-118.53581	T24 FOR CHANGE OF USE RESTAURANT TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21099	17041-10000-34944	4300 W SUNSET BLVD	90029	13	145-5A201  87	5429006011	C2-1D	Central	Hollywood	Silver Lake		1913.02	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.09459	-118.28304	PC FOR RETAIL TI, CONVERT IRREGULAR-SHAPED PORTION OF (E) STORAGE BUILDING (400 SF) TO RETAIL. SCOPE OF WORK INCLUDES NEW PANEL,  CIRCUITS AND EQUIPMENT. TOTAL AFFECTED 400 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21100	10041-10001-10916	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	C2-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	09/22/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.04338	-118.26581	New Video board for staples center. New feeders, panels, Xformer, and circuites. Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21101	15041-20000-39918	16130 W ROYAL OAK ROAD	91436	5	162B141    89	2286016015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	01/23/2016 12:00:00 AM	ADDRESS	34.14212	-118.48322	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 17.92 KW DCNote: Permit fees $0.00 due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21102	14041-20000-30646	12160 N DELANTE WAY	91344	12	219B125    77	2601074002	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Expired	01/05/2017 12:00:00 AM	ADDRESS	34.29475	-118.52792	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21103	10041-10000-17986	960 N BEL-AIR ROAD	90077	5	144B153   463	4370027006	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2010 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.09109	-118.44082	FULLY SPRINKLERED 2-STORY SFD WITH BASEMENT ; there are other structures on the site such as a cabana, mech bldg and fitness bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21104	17041-10001-23894	10250 W SANTA MONICA BLVD LL#2350-(LEVEL B)	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Supplemental plan check and permit for  ""GDBA VIP SANCTUARY"" LOUNGE FACILITY. Changes clouded and noted as Delta 4: Add 2 water heaters, revise panel shchedule to reflects new loads, revise power floor plan to reflects  new loads. No changes on T24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21105	18041-20000-41995	1518 W 15TH ST	90732	15	012B193   258	7560024016	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	33.73078	-118.3106	Plan check for Energy Storage System, Tesla Power Wall 2.0 13.5kWh connected to existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21106	18041-10000-10523	777 S FIGUEROA ST 32ND-FLOOR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	ALTERATIONS IN REST ROOMS ON 32ND FLOOR OF OFFICE BUILDING PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21107	17041-10000-19885	1704 W MANCHESTER AVE	90047	8	097-5A193 332	6037014023	C2-1VL, [Q]R5-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Issued	03/09/2018 12:00:00 AM	ADDRESS	33.95981	-118.30702	PV SYSTEM ROOF MOUNTED. SYSTEM USES 12KW AC INVERTER AND 30 MODULES INTERCONNECTING THROUGH A 800A SERVICE PANEL UNDER SEPARATE PERMIT ON THE  SAME PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21108	17041-20000-20058	865 S FIGUEROA ST 9th Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for energy only. TI to existing office on 9th floor of high rise building. New lighting (incl. emergency). 4,077sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21109	15041-20000-12893	8412 N MELBA AVE	91304	12	192B093   140	2005013007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.22247	-118.63521	PV1Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.7kW. Ungrounded system. (30) 275W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21110	17041-10000-02930	6372 W SUNSET BLVD	90028	13	147A187   590	5546015043	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.09768	-118.32836	Plan check for power and energy Change of use from Restaurant to Salon to existing Building Total load newly connected exceed 400A. Total indoor and outdoor area:21,861 sq ft. B#17016-10000-02002	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21111	13041-10000-06550	2418 W 6TH ST	90057	1	133-5A203  74	5141005010	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM			PC Approved	04/01/2013 12:00:00 AM	ADDRESS	34.06132	-118.27919	electrical permit to be pulled at EPC counter ONLY. PC for energy only.INTERIOR TENANT IMPROVEMENT TO EXISTING RETAIL STORE INCLUDING RESTROOM UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21112	13041-10000-07881	15971 W SKYTOP ROAD	91436	5	162B141   186	2286016007	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	34.14075	-118.48144	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 15.12KW. USING 63 PANELS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21113	16041-20001-32954	1940-1950 S PONTIUS AVE	90025	5	126B153   339	4323025005	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.04323	-118.44116	5/15/2017changes to an approved set of plans.  changes include recalculations to the energy compliance forms.  this is plan check only.  (((((TI to (E) warehouse space.  New 400 A 240V 3 phase service.  Plan check for energy only.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21114	19041-10000-38403	948 N CAHUENGA BLVD	90038	13	144B185   990	5533019002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.08845	-118.32862	COMPLETE TI OF AN EXISTING OFFICE BUILDING.   ADDING NEW LOADS AND LIGHTS. EPC FOR POWER AND ENERGY. AREA: 14,054 SQR FT.BUILDING PERMIT: 19016-1000-30456	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21115	14041-10000-15933	8161 W BEVERLY BLVD	90048	5	138B173   375	5514008045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.07624	-118.36735	"PC FOR POWR AND ENERGY. TENANT IMPROVEMENT FOR NEW ""PETCO"" RETAIL STORE IN EXISTInG RETAIL SPACE.  TOTAL AREA 8512 SQ FT. # OF DEVICES PER APPLICANT COUNT.BUILDING APP # :14016-10000-11541."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21116	16041-20000-40570	5077 N LANKERSHIM BLVD Suite F	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.1626	-118.37361	Plan check for energy only. TI to tenant space - fitness studio. New lighting (incl. emergency) and receptacles. 2,118sqft. Existing permit for this job under application #16041-40000-35690. Additional fees for circuits collected under this permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21117	19041-10000-29812	4343 N LANKERSHIM BLVD	91602	4	165B177   566	2423019075	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	06/29/2021 12:00:00 AM	ADDRESS	34.14909	-118.36531	PC for fire alarm system, scope of work includes a new fire alarm panel and new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21118	10041-10001-20749	1515 W 190TH ST 2nd & 4th-floors	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM			PC Approved	06/07/2011 12:00:00 AM	ADDRESS	33.85852	-118.30531	Tenant improvement on the 2nd and 4th levels of the interior of a  five story office bldg.  <<<<<<PLAN CHECK ONLY FOR VERICATION OF AUTOMATIC TIME CONTROLS FOR LIGHTING>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21119	17041-30000-29983	621 S SPRING ST	90014	14	127-5A211  12	5144024***	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.04533	-118.25178	Plan check for Title 24 only in existing building bath spa. Total area: 3,624 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21120	11041-20000-03946	12121 W WILSHIRE BLVD #950	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	PIN	34.04391963	-118.46825257	energy plan check # 950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21121	19041-20001-33772	22972 W AVENUE SAN LUIS	91364	3	171B097   912	2074004031	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.16215	-118.62745	PV1. INSTALL 8.91 KW DC PV SYSTEM WITH (27) MODULES/MICROINVERTERS. NOTE: INSPECTOR'S FEE UNDER ONLINE PERMIT 19041-90000-33772<<<Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21122	12041-10000-25874	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	02/08/2013 12:00:00 AM		Issued	02/08/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	Installation of 3 new trailer. New panels and Ckt. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21123	15041-10000-24182	7135 N HAYVENHURST AVE	91406	6	183B137    90	2225004042	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.20027	-118.49257	PC FOR POWER. INSTALLING NEW STANDBY GENERATOR 313 KVA. FOR T-MOBILE WIRELESS COMPANY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21124	12041-10000-21859	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Approved	09/14/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	Plan check T24 Energy/Emergency lighting for suite #2100 office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21125	13041-10000-06915	7140 W 91ST ST	90045	11	096B157   959	4119034007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	33.9556	-118.41941	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.4KW USING 30 MODULES. ENPHASE M215 MICROINVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21126	19041-10000-34918	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM			PC Info Complete	09/04/2019 12:00:00 AM	ADDRESS	34.04797	-118.25815	T-24, ENERGY PC ONLY. TENANT IMPROVEMENT OF AN (E) SPACE WITHIN 'MACYS' DEPARTMENT STORE FOR A NEW 'CHOP STOP' FAST FOOD RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1769 SQ. FT.   B#19016-10000-27868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21127	12041-10001-27118	12959 W CORAL TREE PL	90066	11	102B157    34	4211008024	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/01/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	33.97747	-118.42395	applicant paid with check. recalculate fees . MTanEXISTING TI. NEW SWITCHBOARD 2500A. PLAN CHECK FOR POWER AND ENERGY. METHANE. 59810 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21128	12041-10000-15476	1301 N WESTERN AVE	90028	13	147A193   460	5544030054	C2-1	Central	Hollywood	Hollywood Studio District		1909.01, 1911.10	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Expired	08/04/2014 12:00:00 AM	PIN	34.09502134	-118.30958487	Plan check new fire alarm system for single story building. New FACP and devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21129	15041-10000-07737	585 E VENICE BLVD	90291	11	108B145  1530	4241037014	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	33.98974	-118.4619	PC FOR POWR AND ENERGY. TENANT IMPROVEMENT OF (E) RETAIL SPACE(FOOD MRKET). UPGRADE SERVICE TO 1000 A. 6 SUBPANEL. TOTAL AREA 10200 SQ FT. THE PLAN DOESN'T HAVE SIGNATURE, SUBMITAL PER FRANCIS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21130	15041-20000-37986	14071 N RABBIT ROAD	91342	7	231B157   119	2582035017	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.3283	-118.42885	Plan check for PVroof monted system. System size: 4.3kW with 17 modules and 1 inverter. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21131	17041-30000-44036	21914 W STRATHERN ST	91304	3	189B101   301	2110009008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.21537	-118.60452	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (1) load center, and (23) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21132	19041-20000-24202	2434 W AVENUE 33	90065	1	150B213   231	5456002018	R2-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.1101	-118.23467	pv1install roof mounted pv system sized 3KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21133	14041-10000-08208	7100 N VAN NUYS BLVD	91405	6	183B149   161	2217007052	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.19938	-118.44856	pc for power only. not oshpd-3 per applicant. 2 stories. medical office: planned parenthood. BLDG#14016-10-05783: PROPOSED INSTALLATION OF A NEW 10KVC RACK INSIDE COMM'L BLDG. STORAGE ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21134	15041-20000-20815	6320 N TOPANGA CANYON BLVD G-1625	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	PLANECHECK FOR POWER AND ENERGY. FIRST TIME TENANT. EATSA.  BUILDING G UNIT 1625.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21135	15041-20000-07446	16421 W FLANDERS ST	91344	12	213B137   496	2610028018	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.28023	-118.48996	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (30) 255W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21136	16041-20000-06286	16541 W LASSEN ST	91343	12	201B137   139	2678026001	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Apartment			02/23/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.25035	-118.49255	Install a roof-mounted solar array on a residential building part of a shared parcel/service (3 units w/3 meters). Interconnect with a 125A MSP. System size: 4.2kW. (21) 265W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21137	15041-20000-16294	936 S OLIVE ST UNIT 350	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #9 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21138	16041-10003-06786	15838 W BAHAMA ST	91343	12	195B141   286	2672007006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.23272	-118.47775	changes to approved set of plans. revised inverter orientation and locations. revised site plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21139	14041-20001-17284	12312 W OLYMPIC BLVD	90064	11	123B149   659	4259025008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM			PC Info Complete	12/24/2014 12:00:00 AM	ADDRESS	34.03166	-118.45665	[[[[[11/14/14  CHANGES TO APPROVED SET OF PLANS. CHANGES ARE CLOUDED. DELTA 1 changes only. REDISTRIBUTION OF EQUIPMENT AND INSTALLTION OF TWO NEW INVERTERS FOR EMERGENCY]]]]]TENANT IMPROVEMENT FOR AN EXISTING COMMERCIAL TWO STORY BUILDING. ADDING NEW LOADS PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21140	14041-10002-32855	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM			PC Approved	09/08/2015 12:00:00 AM	ADDRESS	34.07583	-118.37407	CHANGES TO APPROVED SET NOTE CHANGES TO DELTA 7. SCOPE INCLUDES THE SPLIT OF A 800AMP SWITCH GEAR TO A NEW 400AMP DISTRIBUTION BOARD AND METHANE NOTE TO PLANS. (((CHANGES TO AN APPROVED SET OF PLANS.  CHANGES CLOUDED DELTA 5.  CHANGES INCLUDE LIGHTING AND LOCATION OF POWER EQUIPMENT.)))Plan check for power and energy. T24. Total area = 1694 sq. ft.   Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21141	16041-10000-45596	724 N CROFT AVE 1-28	90069	5	141B173   341	5528002036	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	05/25/2021 12:00:00 AM	ADDRESS	34.08433	-118.37408	Full plan check to a new 4 story 28 Unit Apartment building over an under ground parking level. New service rated at 2000 Amps 120/208V. Total area: 81,063. B#16010-10000-06158	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21142	15041-10001-23989	2017 N ARGYLE AVE	90068	4	151-5A189 412	5586005009	R3-1XL	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.10746	-118.32543	EXPEDITE PER APPLICANT REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20KW INTERCONNECTED WITH MSP.(84) QCELL MODULES Q.PRO-G3 255-265(2) SUNNY BOY 10000 TL INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21143	17041-10000-29946	6600 N TOPANGA CANYON BLVD #2001	91303	3	180B101   822	2139004044	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Info Complete	02/12/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for T24 only, TI on existing Gamestop store. Install new lights and few circuits on an existing Panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21144	16041-20000-03294	10201 W PICO BLVD Pico West-Garage	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check for Title 24 only. Project site is an existing parking garage. Project scope is carport lighting. Total lighting area = 14,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21145	14041-10000-13866	900 N EDGEMONT ST	90029	13	144B197  1186	5538018010	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.08821	-118.29589	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21146	14041-10000-04615	20770 W NORDHOFF ST Bldg 4	91311	3	198B109   193	2780001058	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.23522	-118.58647	pc for power and energy. BLDG 4. (1 of 4)14010-10000-00411 building description: NEW SPEC CONCRETE TILT UP INDUSTRIAL BUILDINGS; 1-STORY WITH MEZZANINE (BUILDING 4) OFFICE- 4,000 SQ.FT.; WAREHOUSE - 21,672 SQ.FT.HAVE APPLICANT VERIFY 20700 NORDHOFF ST. WITH B.O.E. ADDRESS COUNTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21147	15041-20000-06628	20505 N BERGAMO WAY	91326	12	213B109    24	2701050046	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.27648	-118.57942	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (16) modules, and (16) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21148	10041-10000-17202	4020 S BUCKINGHAM ROAD	90008	8	117B181   723	5032004901	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	ADDRESS	34.01383	-118.34223	INSTALL A NEW FIRE ALARM SYSYTEM IN A FOUR STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21149	09041-10001-21461	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM			PC Info Complete	08/25/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	Change the priviously approved plan. Change the lighting, load, and panel schedules. All the changes are shown with delta 3. Plan check for power and energy.(((((((((((((((((((((((((((TI work on ground floor (bar) and second floor restaurant.))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21150	16041-20000-33052	3601 S TROUSDALE PKWY 3rd-4th Floors	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM			PC Approved	09/16/2016 12:00:00 AM	ADDRESS	34.02017	-118.28558	USC Student Union 3rd and 4th floor corridor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21151	10041-10001-25479	2636 S PORTLAND ST 1ST & 2ND-Floors	90007	8	123A201   237	5123002406	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.02981	-118.28258	RESUBMITTAL OF LOST PLANS.  (PERMIT FEE IS UNDER INSPECTION) <<<<<TI ON THE FIRST AND SECOND FLOORS OF AN EXISTING DORMATORY IN USC.  PLAN CHECK IS FOR POWER. ADITION OF AC UNITS, REPLACING OF THE MAIN SEVICE PANEL,  REPLACING 15 EXISTING OLD PANELS and THE HOUSE PANEL WITH NEW PANELS AND 9 EXISTING FEEDERS ARE ALSO REPLACED WITH NEW FEEDERES.>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21152	11041-20000-05131	3620 S MCCLINTOCK AVE 1ST-2ND FLR	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	08/08/2011 12:00:00 AM	ADDRESS	34.0213	-118.28935	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING 1,710 SF RENOVATION FOR OFFICES AND CHEMISTRY PREP ROOM ON THE 1ST AND 2ND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21153	19041-10001-12038	9225 S AVIATION BLVD	90045	11	093B173    59	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			PC Approved	05/23/2019 12:00:00 AM	ADDRESS	33.95196	-118.37721	SUPPLEMENTAL FOR LOST SET OF PLANS (RE-STAMP)NEW HERTZ CAR RENTAL WITH A 800 AMP SERVICE UPGRADE, CORE & SHELL ONLY. RECONNECT TO EXISTING LOAD.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21154	13041-20000-26399	800 W WILSHIRE BLVD 9TH FLR	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.0493	-118.25841	pc for t24 energy only. renovation of offices on 9th floor. new lighting. new connected load less than 400A WORK DONE ON 9TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21155	16041-20003-05433	8400 N BALBOA BLVD north bldg	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.22376	-118.50243	[[12/1/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA (8) CHANGES ARE CLOUDED. CHANGING FEEDER MSA-1,MSA-2 AND MSB-1, MSB-2]]]]one of two new buildings with retail tenant spaces-SHELL/CORE ONLYThis North Building (16010-10000--00456) plans will be reviewed under this application.A separate application will be required for plan review of the plans for the West Building (16010-10000-004550)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21156	12041-10000-29329	659 N JACON WAY	90272	11	129B121   555	4419012053	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	12/05/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.04882	-118.54744	PV1 7.848KW ROOF-MOUNT SUNPOWER 1 STORY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21157	13041-10001-31391	7241-7245 N ETON AVE	91303	3	186B105   986	2111017033	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			Re-Activate Application	01/21/2014 12:00:00 AM	ADDRESS	34.20229	-118.5956	PLAN CHECK ONLY. REVISION TO APPROVED PLANS TO CHANGE FEEDER TYPE FROM CU TO AL AND TO INCLUDE REVISE MARKED UP CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21158	15041-20001-02779	12476 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	03/01/2015 12:00:00 AM	ADDRESS	33.97888	-118.41041	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21159	16041-10000-34527	1002 N HUDSON AVE #1-5	90038	13	144B185   953	5533013016	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			Reviewed by Supervisor	10/13/2016 12:00:00 AM	ADDRESS	34.08908	-118.33194	Plan check for power only to a new 4 story 5 unit apartment building. New 800 A service 240/120 V 1phase 3wire, all equipment shown on plans is newly installed.Note: Plan check only, Applicant want request to set it to plan check only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21160	17041-20002-24712	1259 W FLORENCE AVE	90044	8	102B197  1150	6014034030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	33.97475	-118.29784	10.31.2017- Update plans to correctly reflect rating of existing breaker (70A) and associated existing feeder wiring. Changes clouded.======PV 1. Single family dwelling on residential roof-top. PC for 7.8 KW rooftop solar. PC for 34 Axitec AC-265P modules and one Fronius Primo 7.8 central inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21161	17041-10000-18217	16925 W DORMIE PL	91436	5	168B133   451	2289016039	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.15405	-118.50213	Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system.  Total system size = 16.2 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21162	13041-10000-24786	1716 S CRENSHAW BLVD	90019	10	126B185   490	5072002020	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.04302	-118.32912	PV1 ROOF-MOUNTED 7.5KW DC MICROINVERTER INSTALLATION ON NON-STANDARD PLAN .(30 ) MODULES: HANWHA SOLAR HSL60P6-PA-250T(30) ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21163	14041-20000-01133	8125 N GENESTA AVE	91406	6	189B133   131	2204025036	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.21782	-118.50459	pv1 single family dwelling. total system size 3kw ac using transformerless inverters nonstandard plan using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21164	14041-10000-08999	5506 N MORELLA AVE	91607	2	174B169  1086	2348005009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.17059	-118.38982	PV1, INSTALL 8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTERS: SOLAREDGE SE3800A-US-ZB-U &(32) MODULES: YINGLI YL250P-29bREVISION TO APP # 13041-10000-32282	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21165	19041-10000-51236	11246 N ALTA AVE Lot 29	91345	7	210B145   549		C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.275	-118.46863	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION WITH AN EXISTING SERVICE OF 200 AMPS. INSTALLTION INCLUDES 13 MODULES AND 1 CENTRAL INVERTERSYSTEM SIZE: 4.095 KW DC; 3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21166	13041-10000-07080	11101 S LA CIENEGA BLVD	90045	11	087B173    55	4129038025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	33.93379	-118.37023	UPGRADE OF DISTRIBUTION SECTION FOR WAREHOUSE BUILDING. NEW 600A DISTRIBUTION FOR 2 NEW INDUSTRIAL COOLERS, EQUIPMENT, AND 4 NEW BRANCH CIRCUITS. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21167	16041-10000-39090	633 W 5TH ST 35th &36th	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Title 24 plan check.  T.I. to 35th and 36th floor of existing commercial office highrise.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21168	15041-10000-04563	2830 E LANCASTER AVE	90033	14	132A229     7	5202024903	A1-1, RD2-1	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05693	-118.19491	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 7000 SQ FT. (GYM AREA)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21169	14041-10001-32437	200 WORLD WAY # 235	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Change to an approved set by modifying the load and adding (5) new circuits.Note. All changes are under delta-5 only.(((PC FOR POWER AND ENERGY. TERMINAL 2 FRESH BROTHERS FAST FOOD (235). TI. TOTAL AREA 725 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21170	16041-20000-41322	1147 N VIA DE LA PAZ	90272	11	129B125   316	4422021005	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.05045	-118.52643	Plan check for installation of solar pv system, roof-mounted on a SFD. Interconnect with a 200A. Derating the main to 175A. 10.88kW ungrounded system.  (34) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21171	14041-20002-10925	9549 S DEFIANCE AVE	90002	15	093A213   229	6048021032	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	33.94918	-118.24539	4/22/2015 Changes to an approved set of plans. Changes are to the PV module layout only. System size and equipment has remained the same.*****Previous Work Description*****Restamp for lost plans.  Plan check only.*****Previous Work Description*****PV1.  mounted-roof system with (16) micro inverter enphase M215-60-2LL-S22, and (16) module of Canadian solar CS6P 250P, 250 watt each. total AC: 3.44kw.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21172	19041-20001-40171	7950 N WILLIS AVE 1-4	91402	6	189B149   351	2210020007	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.2157	-118.45518	Plan check for 5.76 kW DC / 4.896 kW AC photovoltaic system for multifamily building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21173	18041-10000-05318	4331 S HONDURAS ST	90011	9	114A213   444	5116020900	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.00452	-118.24413	PC for T24 only for removal of oudoor HID fixtures and replace with new LED fixtures. Total are 3320sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21174	13041-10000-20719	8631 W 3RD ST 120-121	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.07373	-118.38036	TITLE 24 FOR 1ST FLOOR OF 11 STORY BUILDING: MEDICAL OFFICE. PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. TENANT IMPROVEMENT FOR SUITE 120 & 121.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21175	11041-10000-19166	515 S FIGUEROA ST	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	12/15/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	T.I. TO AN EXISTING OFFICE BUILDING.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21176	10041-10000-20316	7900 S LOYOLA BLVD	90045	11	099B161     3	4113001004		West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2764.00, 2765.00	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	33.96604	-118.41693	"TI REMODEL IN ""PEREIRA HALL SOUTH"" BUILDING IN LOYOLA MARYMOUNT UNIVERSITY:   PARTTIIONS, DOORS, CEILINGS, FINISHES IN AN EXISTING SCHOOL. PLAN CHECK FOR POWER AND ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21177	15041-20000-09641	12682 W SANDHILL LANE 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/01/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.97708	-118.41507	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: SYSTEM SIZE: 1.38KW   LANE # 36 MODULES(1) 3.0 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21178	19041-20000-35081	614 S MATEO ST	90021	14	126A217   204	5164013015	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.03738	-118.23248	TENANT IMPROVEMENT FOR RETAIL P.C FOR TITLE 24 ONLY. TOTAL AFFECTED AREA 2,004 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21179	13041-20000-33356	6301 S NORMANDIE AVE	90047	8	105B193   984	6002033044	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	PIN	33.98219552	-118.30056415	PC FOR T24 ENERGY ONLY. WORK DONE IN COMMUNITY ROOM. NEW LIGHTING. PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21180	17041-10000-40159	1425 W CARSON ST	90501	15	051B193   867	7349031032	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.83169	-118.3024	Remove HID fixtures and replace with new LED fixtures  T-24 only.9000 SQ.FT OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21181	13041-10001-33021	3941 S BUCKINGHAM ROAD	90008	10	117B181   584	5045006010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.0152	-118.34156	Expedited RSES plan check per applicant request.[][][]PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (23) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21182	17041-10000-40439	10334 W BANNOCKBURN DR	90064	5	123B161   289	4318024009	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.03563	-118.41047	PC FOR TWO ENERGY STORAGE UNITS POWER WALL 2.BATTERY RATED AT 5.8KWac (13.5KW), (PV ALREADY EXISTING)SCOPE INCLUDES NEW LOAD CENTER (125AMP)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21183	19041-10000-43445	2049 S CENTURY PARK EAST 1500	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Energy plan check for a T.I. Scope includes new lighting and equipment with a total lighting area of 22,369-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21184	13041-10000-33116	8609 N GLORIA AVE	91343	12	192B141    37	2673004029	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.22684	-118.48094	PV1, Install 4 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE3800A-US. (16)modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21185	17041-10001-26088	1755 W CHANDELEUR DR	90732	15	015B189    87	7559024002	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			PC Approved	09/29/2017 12:00:00 AM	ADDRESS	33.73912	-118.31461	EXPEDITED FEE FOR SOLAR SYSTEM ORIGINAL PERMIT # 17041-10000-26088PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE (5.0KVA) WITH BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF 1 INVERTER (SOLAREDGE 5000A) WITH 20 MODULES (SOLARCITY) AND POWER OPTIMIZERS(P400).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21186	14041-20001-14159	11600 W WILSHIRE BLVD Unit 199	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	34.05034	-118.45947	Modifications to approved set.  Change of lighting fixtures and corresponding updated Title 24 Part 6 certificate of compliance lighting forms.  (((Renovation of existing commercial tenant space for coffee shop.  Title 24 plan check for changes to lighting system.  Newly connected load under 400A.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21187	17041-20000-31240	5120 N LAUREL CANYON BLVD	91607	2	171B165   731	2355008039	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			08/31/2017 12:00:00 AM			PC Approved	10/20/2021 12:00:00 AM	ADDRESS	34.1637	-118.39629	600A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21188	18041-20000-38645	1025-1035 N HIGHLAND AVE	90038	4	144B185   830	5532028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.08969	-118.33884	Demo (E) 125 kW 208Y/120V generator and reconnect (E) loads to (E) 500 kW 480Y/277V generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21189	13041-10000-28708	1511 N WILCOX AVE	90028	13	147A187   100	5547017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Expired	11/10/2015 12:00:00 AM	ADDRESS	34.09839	-118.33114	remodel retail storeplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21190	10041-20001-25890	9434 W CHEROKEE LANE	90210	4	150B165    67	4387032016	RE15-1-H, RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2011 12:00:00 AM			PC Approved	10/21/2011 12:00:00 AM	ADDRESS	34.11079	-118.40008	Modification to an approved set of plans.  Relocating the 1600 AMP Switchboard from inside to outside.  <<<<<<Plan check for new 1600A service and addition to existing single family dwelling.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21191	18041-10000-22058	10900 W WILSHIRE BLVD STE 300	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR  819 SQ FT. UROGEN PHARMA. SUITE 300.BUILDING PERMIT # 18016-10000-10911	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21192	13041-10001-35582	9700 W SOMBRA TER	91040	7	201B181    55	2545006017	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.25115	-118.342	Expedited RSES plan check per applicant request.{{PV1, Install 3 kW DC roof-mounted solar array for a  house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (12) modules: Rensola Solar JC250M-24/BB.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21193	12041-10000-29381	106 S HIGHLAND AVE	90004	4	138B185   282	5513013002	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	PIN	34.07323254	-118.33814671	PV1:  5.06 KW roof mounted PV system for a single family residence.  23 modules, one inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21194	18041-20000-42076	1999 S AVENUE OF THE STARS ste 3320	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21195	19041-20000-00500	9223 N OWENSMOUTH AVE	91311	12	198B105   134	2746012039	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Closed	10/19/2021 12:00:00 AM	ADDRESS	34.238	-118.60204	Plan check for Title 24 only in existing space walking refrigerator. Total area: 5235 sq ft.B#18016-20000-31919	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21196	19041-20000-29000	19864 W FALCON CREST WAY	91326	12	217-5A115 120	2701025015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM			Reviewed by Supervisor	08/30/2019 12:00:00 AM	ADDRESS	34.28944	-118.5668	Plan check for PV roof mounted with battery back up system, PV sysem size: 6.48KW DC, 5.76KW AC with 18 AC Modules and 1 Sonnen Battery  System 10KWh	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21197	12041-20000-28999	15230 W VANOWEN ST	91405	6	180B145    39	2235004009	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM			Reviewed by Supervisor	02/13/2013 12:00:00 AM	ADDRESS	34.19371	-118.46506	Converting a storage space of an adjacent space from storage to retail for use of Office Depot..  Plan check for T24 and emergency lighting only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21198	16041-10000-23249	20549 W DEVONSHIRE ST	91311	12	204B109   127	2707013030	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.25742	-118.58102	(TI) Title 24 (6574SQ. FT.) PLAN CHECK FOR LIGHTING AND POWER.NEW LIGHTING AND RECEPTACLES FOR EXISTING BUILDING CONVERTED TO CHARTER SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21199	18041-30000-18002	1800 N VINE ST 3RD FLR	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.10393	-118.3265	PLAN CHECK FOR T24 ONLY, TI ON 3RD FLOOR EXECUTIVE OFFICE SUITES, CORRIDORS, OFFICES AND BREAK AREA. TOTAL AREA: 18,665 SQ.FT, NEW CONNECTED LOAD < 200A(B# 18016-10000-14440)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21200	13041-20000-34524	21031 W VENTURA BLVD 409	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	PIN	34.16717222	-118.59179488	Office Tenant Improvement	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21201	10041-10000-16673	6515 S NORMANDIE AVE 1-20	90047	8	105B193  1578	6015008017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.00	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	33.98012	-118.30055	20 units new apartment bldg , type 5 , 4 stories and basement. power , lighting and energy. variance for fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21202	15041-20000-39205	21040 W VICTORY BLVD #203	91367	3	180B105    53	2149003035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.18814	-118.59248	Plan check for Title 24 only for Bakery in existing space. Total area: 2,018 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21203	18041-20000-24490	161 S NORMANDIE AVE #1-13	90004	10	138B193  1214	5518002012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Apartment			06/29/2018 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.07196	-118.30064	Plan check for power and energy for new 2 story  13 units apartment building Total area: 7500 sq ft. 17010-20000-03642	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21204	15041-20000-01339	6858 N LONGRIDGE AVE	91605	2	183B157   749	2327007064	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.19558	-118.4213	PV1 SFD. TOTAL SYSTEM SIZE 3.6KW DC/ 6KW MAX AC. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21205	13041-10000-14120	10810 W PALMS BLVD	90034	11	120B161  1013	4252037033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.02	Electrical	Electrical	Apartment			05/30/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.02312	-118.41412	fa for apartment 27 units. 1 panel and 38 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21206	12041-10000-02610	23401 W JONATHAN ST	91304	3	189B093    54	2020021028	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.21762	-118.6363	Plan check for 8.46KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21207	17041-20000-18120	8840 S READING AVE	90045	11	096B169   967	4125017009	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Issued	05/31/2017 12:00:00 AM	ADDRESS	33.95666	-118.38145	new fire alarm system 74 devices and facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21208	14041-20000-17297	6430 W SUNSET BLVD 7TH FLR	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	PC FOR T24 ENERGY ONLY. NEW LIGHTING. EXISTING OFFICES. PERMIT ISSUED UNDER THIS APPLICATION. WORK DONE IN 7TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21209	13041-20000-21835	3114 N DONA ELENA PL PV-1	91604	2	156B169   184	2381025007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.12655	-118.38376	PV-1. Plan check for AC modules. Rooftop installation. 5.760kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21210	19041-20001-13714	3051 S MCCONNELL DR	90064	13	156B209   218	5458004016	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	34.03591	-118.40165	Wiring method changes.  (2) sets of roof-mounted conduits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21211	17041-10001-36204	10250 W SANTA MONICA BLVD STE. 1440	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Plan check for a lost of plan. (((Full PC for first time tenant ""Next Health"" Ste. 1440 at Westfield Century City.  Install new electrical equipments,  total affected area: 1,882 sq.ft )))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21212	17041-10000-30138	17616 W VENTURA BLVD	91316	5	171B129   417	2290008019	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.1618	-118.5168	RESTAURANT TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21213	14041-20001-03103	12600 W VOSE ST	91605	2	183B161   418	2324023018	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.19827	-118.40747	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21214	19041-10000-07561	7201 S SAN PEDRO ST	90003	9	102B205   874	6022009029	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	33.97452	-118.26972	PLAN CHECK FOR POWER ONLY. SCOPE OF WORK INCLUDES INSTALLATION OF NEW GAS DISPENSERS AND PANEL.T-24 PLAN CHECK FOR CONVENIENCE STORE PERFORMED UNDER APP # 18041-10000-16739, PANEL 11A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21215	18041-10000-09121	8945 N FULLBRIGHT AVE	91311	12	195B113    38	2781001023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Info Complete	10/25/2018 12:00:00 AM	ADDRESS	34.2337	-118.57775	NEW 1600 AMP SERVICE AND PANELBOARDS AT MANUFACTURING FACILITY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21216	18041-10000-17670	1082 W 30TH ST	90007	9	121-5A201 139	5039019045	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.02731	-118.28621	Plan check for a fire alarm system in a two story, and (16) units apartment building wih (1) main fire alarm panel, and (47) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21217	13041-10000-10390	3580 W WILSHIRE BLVD # 800	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.06156	-118.3028	EXISTING OFFICES REMODEL. TI IN SUITE 800. PC FOR ENERGY ONLY. TOTAL AREA 1000 SQ FT. PART OF HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21218	16041-20000-35083	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.20615	-118.41279	IMPROVEMENTS FOR COMMERICAL RESTROOM. REPLACEMENT OF LIGHTING 1 FOR 1. PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21219	18041-10000-09555	2025 S AVENUE OF THE STARS N. Tower	90067	5	132B161   724	4319004163	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	09/19/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	PC FOR NEW FA IN HIGH RISE NORTH TOWERSCOPE INCLUDES 3193  DEVICES AND 50 PANELS. B#15010-10000-02800	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21220	10041-10000-15977	43 N BEVERLY PARK CIR	90210	5	153B161    34	4386014023	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.11687	-118.41705	INSTALLATION OF ROOF- MOUNTED  43.29 KW SOLAR SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21221	12041-10001-15654	11444 W OLYMPIC BLVD	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	ADDRESS	34.03654	-118.44363	REMODELING EXISTING OFFICES ON THE 6TH FLOOR; PERMIT WAS OBTAINED ON 12041-90000-15654.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21222	17041-20000-27612	203 N OXFORD AVE 1-8	90004	10	138B193   645	5517005015	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM			Reviewed by Supervisor	09/12/2017 12:00:00 AM	ADDRESS	34.07544	-118.30827	New 5 story 24 unit apartment building.  1200 A 120V/208Y service with optional standby generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21223	15041-10000-11544	1100 S GLENDON AVE 17th Floor	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.06074	-118.44418	T24 FOR EXISTING HIGHRISE BUILDING ON THE 17TH FLOOR. REUSING EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21224	18041-10000-12380	714 N FIGUEROA ST	90012	1	135A213   210	5407005016	C2-2D	Central	Central City North	Historic Cultural		2071.01	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.06374	-118.24542	TI  IN AN EXISTIND RETAIL. PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21225	16041-20000-21678	20557 W DEVONSHIRE ST	91311	12	204B109   127	2707013030	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.25742	-118.5812	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO (E) RESTAURANT. SIZZLERS . 4000SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21226	17041-10000-43317	2722 S WESTERN AVE	90018	8	123B193  1019	5053010005	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Apartment			12/01/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.03011	-118.30877	PC FOR NEW FA IN  SENIOR HOUSING (R2.1 OCC.)TOTAL DEVICE COUNT  12 DEVICES AND 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21227	18041-10000-15413	2110 E SANTA ANA BLVD NORTH	90059	15	088-5A215 634	6067028013		South Los Angeles				2430.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	33.93615	-118.23455	Plan check for a 3KW AC / 2.61KW DCroofmounted system with (9) modules and a 3KW inverter  interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21228	15041-20000-21102	14403 W VICTORY BLVD	91401	6	180B149   827	2237024009	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.18687	-118.44675	Plan check for Power only for new equipments(Washers and Dryers) replacement in existing lauandry. Existing lighting, service, distribution, panels, circuit breakers, feeders and branch circuits. Requested by Inspector to get plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21229	17041-10000-20780	13641 W SHERMAN WAY	91405	2	183B157    16	2328007002	C1-1VL, R3P-1	South Valley	Van Nuys - North Sherman Oaks			1271.03	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.20136	-118.4302	PC FOR STARBUCKS TI. PC FOR POWER AND ENERGY. NEW 600A SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21230	11041-10000-26372	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM			PC Approved	12/09/2011 12:00:00 AM	ADDRESS	33.98645	-118.44148	PLAN CHECK T24 ENERGY - OUTDOOR LIGHTING WEST END AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21231	15041-30001-23700	15760 W STRATHERN ST BLDG. 2	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	ADDRESS	34.21559	-118.47701	Changes to approved set.  Changes affect building 2 only.  Changing location of subpanel.  Subpanel is changed from split bus to regular bus.  Lighting has been revised throughout.*****Previous Work Description*****          Plan check for power and energy.  Total area = 1,576 sq. ft. (indoor) + 100 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21232	16041-20001-19820	414 S CLOVERDALE AVE 1-58	90036	4	135B181   423	5508005029	[Q]R4-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			PC Approved	08/02/2016 12:00:00 AM	ADDRESS	34.06644	-118.34603	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE : 55. 5 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21233	16041-10004-19933	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Closed	09/01/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC FOR ENERGY FOR FACILITY IMPROVEMENT FOR TERMINAL 3 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUSING OPERATION, OFFICE RENOVATION, AND IMPROVED FINISHES AND MILLWORKTHE APPLICATION 16041-10000-11825 IS RELATED TO CONNECTED LOAD OTHER THAN THE SCOPE OF THE WORK FOR THIS PROJECT.BUILDING APPLICATION IS 16016-1000-11866. TOTAL AREA 4991 SQ FT.(((((   3-9-2017   M.Z   addition of two fixturers in the vestibule area  and emergency lighting)))))))))(((((3-15-2017     M.Z   addition of lights and emergency in the bathrooms  and 4 new branch ckt)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21234	15041-20000-30241	1922 W 82ND ST	90047	8	099B193  1351	6035015009	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			PC Approved	10/05/2015 12:00:00 AM	ADDRESS	33.96447	-118.31208	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.32 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21235	19041-20000-42988	2336 S WESTWOOD BLVD 1-23	90064	5	126B157   711	4320002028	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Apartment			10/22/2019 12:00:00 AM	07/08/2021 12:00:00 AM		Permit Finaled	08/01/2023 12:00:00 AM	ADDRESS	34.04174	-118.42968	1600A 240/120V 3ph-4w service, distribution, power, and lighting for new building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21236	10041-10000-24741	6922 W HOLLYWOOD BLVD 2ND FLOOR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.10137	-118.34103	TI IN AN EXISTING OFFICE AREA ON THE 2ND FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMEGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21237	18041-10001-26203	10306 W VENICE BLVD	90232	5	117B165    21	4208005038	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM			PC Info Complete	05/21/2019 12:00:00 AM	PIN	34.02078391	-118.40268239	Changes to an approved set, all changes are under delta 3. No new equipment was added. ((PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT WITHIN CORE AND SHELL. CONNECTING TO EXISTING DISTRIBUTION EQUIPMENT WITH APPROX. 200A OF NEW CONNECTED LOAD. TOTAL AFFECTED AREA = 1105 SF.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21238	11041-10000-18291	16027 W VENTURA BLVD	91436	5	168B141   538	2261022106	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Public Safety Only			08/29/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	09/13/2011 12:00:00 AM	ADDRESS	34.15641	-118.48225	REPLACING FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21239	16041-10000-34775	334 S MAIN ST KIOSK #1	90013	14	129A213   144	5148001031	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.04841	-118.24668	Energy plan check for a kiosk retail (take out coffee shop). Total area 473 SQ ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21240	19041-20000-20911	7609 N VICKY AVE	91304	12	186B097   241	2013008021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.20859	-118.6201	PV1.  Install 14.52 kW DC / 13.166 kW AC CEC grid tied roof mounted PV system.  (44) modules with (22) microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21241	14041-10001-13350	123 S HOBART BLVD	90004	10	138B193  1043	5517012030	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.07303	-118.30563	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21242	11041-10000-10901	6420 W WILSHIRE BLVD STE  700	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM			PC Approved	05/26/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I.  Relocating and installing light fixtures on the 7th floor of a high rise building.  Plan check is for Title-24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21243	18041-10000-15022	1038 N LARKER AVE	90042	14	157-5A235 101	5716030044	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.12541	-118.1705	PC for 5.2kW(ac)/4.55kW(dc) rooftop solar for SFD. Installing 14 modules with four RPS, central inverter and 200A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21244	15041-10000-28433	6103 N KESTER AVE	91411	6	177A149    55	2242024051	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.18084	-118.45764	PC for energy only t-24. Scope of work: remove HID light fixtures and replace with new led fixtures. Sq ft = 7800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21245	19041-10000-29718	6735 N ODESSA AVE	91406	6	180B137    55	2231006012	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.19283	-118.49038	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21246	15041-20002-19191	21501 W VENTURA BLVD	91367	3	171B105     7	2168027031	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/03/2015 12:00:00 AM			PC Approved	11/03/2015 12:00:00 AM	PIN	34.16881252	-118.59888323	11/3/15: Chnages to approved set of plan. PC only, adding light fixtures. Permit under: 15041-20001-1919106-30-15 Change to approve set of plan. Changes includes remove fixture 3 (8)in office and replace with  fixture 1A(18)[[[[[Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 10,210 sq. ft.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21247	12041-20000-06205	500 S VIRGIL AVE #102-#103	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Finaled	08/13/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	T.I. to medical office space.  Install 1200 Amp, 500KVA transformer, subpanels, equipment, branch circuits, and lighting.  Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21248	09041-10001-17587	8236 N COLDWATER CANYON AVE	91605	2	192B161   205	2305001032	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	05/10/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.2209	-118.41422	REVISED APPROVED SET OF PLANS TO RELECT AS BUILT CONDITIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21249	14041-20000-15732	601 S FIGUEROA ST	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Expired	07/25/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	New fire alarm system in a single story school. New  FACP with remote anunciator. 33 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21250	19041-20001-15543	1033 S HILGARD AVE 1-91	90024	5	132B153   150	4360002033	[Q]R3-1-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	34.06076	-118.44212	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21251	15041-10000-20560	1440 S SEPULVEDA BLVD Roof	90025	5	129B149    38	4324016094	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.05107	-118.44699	PC FOR POWER. REPLACING DISTRIBUTION PANEL DPA WITH 600 A , RECONNECTING EXISTING ROOFTOP LOADS. ADD NEW DISTRIBUTION PANEL DPM 400 A, RECONNECT TO EXSITING LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21252	12041-20000-19726	20730 W DEARBORN ST B and C	91311	12	198B109   156	2748037022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.23712	-118.58532	Plan check for energy and emergency lighting. Units B & C. 21290 sqft,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21253	15041-10000-29959	3007 W 8TH ST	90005	10	132B197   454	5094011023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.0579	-118.29206	PC for Energy only,  TI for cigarette shop, total area: 243 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21254	19041-20001-50865	15418 W HAMNER DR	90077	5	156B145    86	4378015017	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.12552	-118.46293	"12-13-2019 Changes to an approved set of plans, Changes include change inverter to Solaredge(7.5KW) and relocation of equipments. Correct work description to ""Energy Storage System Size: 27KWh"". All changes has been clouded."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21255	15041-10001-35527	1415 N DEVLIN DR	90069	4	144B169    34	5560037018	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2017 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	ADDRESS	34.09476	-118.38664	PLANS REVISED TO INCLUDE A STANDBY GENERATOR AND ATS FOR THE SUMP PUMPPermit refer to Building application number: 14010-30000-02038(((((Plan check for power single family dwelling 600A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21256	13041-10000-19736	10523 N WHITE OAK AVE	91344	12	207B129   824	2733008004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.26206	-118.52004	PV-1 PLAN CHECK INSTALLING ROOF MOUNTED PHOTOVOLTAIC SYSTEM. 1 STORY. 10.78 KW.  TRANSFORMERLESS, UNGROUNDED. 2 INVERTERS: POWER-ONE # AURORA PVI 6000 (6000W) & POWER-ONE # AURORA PVI-3.0 ( 3000W). 44 PANELS : TRINA SOLAR # TSM-245PC05 (245W).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21257	18041-10000-18150	7141 W 91ST ST	90045	11	096B157   913	4119031006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	33.95577	-118.41955	Install a new 13.5 KWH Battery system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21258	16041-10000-06323	888 S WAYS ST	90731	15	015B205     7	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.73789	-118.26549	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (RESTROOM/LOUNGE/LOCKER ROOM). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.  TOTAL AFFECTED AREA IS 1447 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21259	19041-20000-36681	22101 W ERWIN ST	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.183	-118.60884	Plan check for Pv roof mounted system, PV system size: 24.36KW DC, 21.7KW AC CEC with 56 PV Modules and 2 inverters(14.4KW and 9.0KW)Note: This is 12 Buildings on 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21260	10041-10000-13764	3455 S OVERLAND AVE	90034	5	120B161   672	4254026006	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2699.02, 2717.01	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	02/11/2011 12:00:00 AM	ADDRESS	34.02511	-118.41213	title 24 and emergency lighting one story restuarant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21261	19041-10000-16856	8317 N ETIWANDA AVE	91325	12	192B125   608	2786015008	RS-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	05/09/2022 12:00:00 AM	ADDRESS	34.22136	-118.53185	FULL PLAN CHECK FOR NEW CORE AND SHELL CONSTRUCTION  MEDICAL OFFICE BUILDING WITH SERVICE SIZE OF 2000 AMP,  277/480 3PH. SCOPE OF WORK INCLUDES NEW EQUIPMENTS AND CIRCUITS. TOTAL EFFECTED AREA 16207 SQFT. BLD: 19010-10000-01906	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21262	16041-10000-10241	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Info Complete	03/23/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMERCIAL BUILDING FOR AN LAX, TERMINAL 1, LEVEL 2, FOOD COURT STARBUCKS SHOP. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 898 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21263	18041-30000-19815	5700 N CANOGA AVE 3rd FLR	91367	3	174B105    83	2149019015	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.17365	-118.59715	Plan check for T24 only, TI on (E) 3rd floor commercial space. Install 225 A panelboard, new circuitry  new load at approximately 200A. Area under the scope: 16,252 sq.ft(B# 18016-10000-13770)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21264	19041-20000-52402	1712 N GLENDALE BLVD	90026	13	142-5A209  51	5423008014	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.20	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	06/03/2021 12:00:00 AM		Permit Finaled	01/18/2023 12:00:00 AM	ADDRESS	34.08581	-118.25934	$0 fee per AB1414.PV3. Install 94.9 KW DC/85.19 KW AC CEC roof mounted PV system. Install (260) modules with (2) 20 KW and (1) 33.3 KW inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21265	18041-10000-47221	1444 S SOUTH SEASIDE AVE	90731	15	012B205     9		[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.72411	-118.26867	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21266	13041-10000-05373	8201 W BEVERLY BLVD 400	90048	5	138B173   380	5514008046	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	03/01/2013 12:00:00 AM	ADDRESS	34.07624	-118.36815	ti to existing office.  4020 sf. Load is less than 400 amps per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21267	19041-20000-18234	7737 N BURNET AVE	91405	6	189B145   624	2209033058	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.21128	-118.46306	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 4,050 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21268	18041-10000-21948	6333 W SANTA MONICA BLVD	90038	13	144B185   687	5533008012	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Issued	07/05/2018 12:00:00 AM	ADDRESS	34.09087	-118.32785	PC FOR INTERIOR & EXTERIOR TI FOR OFFICE BUILDING.  CHANGE OF USE AT 1ST FLOOR FROM OFFICE TO GYM.  FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD <400A.TOTAL AFFECTED AREA  4421 SQ.FT (INDOOR AND OUTDOOR). SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT AND LIGHTS. B#18016-10000-13229	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21269	14041-10000-30185	11115 W PENROSE ST	91352	6	195B173   493	2408026017	[T][Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.22812	-118.37306	Remove HID light fixtures and replace with new LED fixtures in a 1092 sq ft warehouse space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21270	10041-10000-08719	1248 S FIGUEROA ST	90015	9	126A205    19	5138025014	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.04096	-118.2674	Two story  bldg , 2nd floor ti, existing service. pc for power, lighting and energy. ( core & shell is allready approved # 09041-30000-16629)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21271	18041-20000-24424	4821 N FORMAN AVE	91601	4	168B177   438	2420016018	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.15841	-118.35305	install(2) battery back up systems to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21272	12041-10000-13199	601 W 5TH ST #210	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			Corrections Issued	06/07/2012 12:00:00 AM	ADDRESS	34.05049	-118.25386	Demo all existing lights and receptacles,install new receptacles/switches at new wall locations,reinstall existing lights/sensors,use all existing power  Load is less than 400A per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21273	13041-20005-03925	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	34.0344	-118.45642	Changes from previously approved plans.  Permit issued under 20003 PCIS #.  Addition of one outdoor building sign resulting in changes to title 24 compliance sheets.*****Previous Description*****changes to approved set of plans. changes to site lighting t24 energy only. site lighting 82000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21274	19041-10000-30112	7900 S LOYOLA BLVD 1st floor-Malone	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM			Corrections Issued	08/02/2019 12:00:00 AM	ADDRESS	33.96604	-118.41693	ENERGY PC ONLY FOR NON STRUCTRUAL T.I. COUNSELING LOUNGE CONFERENCE ROOM AND STORAGE ROOMS. AREA OF SCOPE 524SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21275	10041-20000-05666	12201 W WILSHIRE BLVD	90049	11	126B145   226	4264026007	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	PIN	34.04355562	-118.46870171	Installing light fixtures and some receptacles in office area and retail space. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21276	15041-10000-43196	850 E 88TH ST	90002	9	096A209   152	6042019028	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	33.95732	-118.25896	PV1 installation to a single family home. Installing a 3.0 kw inverter and 11 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21277	16041-20000-10959	3200 W ADAMS BLVD	90018	10	123B189   714	5052015032	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.03243	-118.31875	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from a church to an indoor basketball court and auditorium (accessory building to an existing school). Occupant load is 412. Total lighting area = 14,080 sq. ft.Note: Building application has been generated under 15016-20000-19168	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21278	14041-10000-22078	320 N NEWLAND ST	90042	14	154-5A231  48	5493005018	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.11918	-118.18475	Installation of roof mounted solar PV system.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21279	16041-10000-38844	16908 W PARTHENIA ST	91343	12	195B133   472	2689018022	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.22835	-118.50086	"T-24, PC FOR ENERGY. TI OF EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1673 SQ. FT. COMPLY WITH DEPARTMENT ORDER effective date 12/09/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21280	15041-30000-44035	22928 W CANTARA ST	91304	12	189B097   146	2014005003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.21751	-118.62661	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21281	13041-10000-25507	5500 W RIDGE OAK DR	90068	4	153B193   161	5580027018	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.1143	-118.30983	PV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. SYSTEM SIZE: 12.54 KW SYSTEM. 44 MODUELES. 44 SOLAR EDGE OPTOMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21282	12041-10000-13735	1611 N KENMORE AVE	90027	13	147B197   452	5543005014	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.10026	-118.29748	Plan check T24 Energy/emergency lighting for existing 2-story nursery school building. Permit for replacing existing lighting ballast/lamps and two misc permits for low voltage wiring on each floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21283	11041-10000-17908	4068 N KRAFT AVE	91604	2	162B169   328	2368020030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	09/19/2011 12:00:00 AM	ADDRESS	34.1418	-118.37992	INSTALLATION OF A 4.79KW photovoltaic system on the roof of a SFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21284	15041-10000-31620	7301 N MEDICAL CENTER DR	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.20262	-118.62963	TI TOAN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 4107.PARTIAL PERMIT FEES FOR THE 4TH FLOOR PAID UNDER APPLICATION NUMBER 15041-90000-28695.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21285	17041-20002-07909	19601 S HAMILTON AVE	90502	15	057B197    81	7351033023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM			PC Info Complete	01/30/2018 12:00:00 AM	ADDRESS	33.85319	-118.28624	01/30/2018 Changes to an approved set of plans. Changes include the installation of a new transformer, new distribution equipment, and provisions for the installation of 3D printing equipment. There has been a change of engineer.05/08/2018:Permit fees will be paid under seperate application # 18041-10000-16892, due to finaled master application. *****Previous Work Description*****17041-10001-07909 Couduit only permit*****Previous Work Description*****17041-10000-07909 Plan check for power and energy in hazadous location for 3 dimensional printing aluminum powder inside the printing machine. Total area: 4,620 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21286	14041-20001-17614	8935 N ORION AVE	91343	7	195B141   247	2654001024	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.05	Electrical	Electrical	Apartment			04/26/2016 12:00:00 AM			PC Approved	04/26/2016 12:00:00 AM	ADDRESS	34.23288	-118.4722	04/26/2016 Changes to an approved set of plans. All changes have been clouded. Areas of refuge have been removed as they are not needed, per approved structural plans. *****Previous Work Description*****PC FOR POWER AND ENERGY. 3 STORY BUILDING. (33) UNITS OVER BASEMENT PARKING.  7 TYPES APARTMENT. TOTAL AREA 20265 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21287	17041-10001-23341	11401 N PORTER RANCH DR BLDG 6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	06/30/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY.  BLDG 6 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 6 of 10.  Type I.       Building permit #17010-10000-02383	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21288	13041-20000-26719	15260 W VENTURA BLVD #680	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.15356	-118.4658	Change to lighting and relocation of switches.  Load is less than 400 amps.  PLAN CHECK ONLY for ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21289	11041-10000-20293	5525 N KLUMP AVE 1-49	91601	4	174B173  1181	2350006042	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	11/07/2011 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.17064	-118.37542	New fire alarm system for a new building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21290	19041-20000-51017	8501 N FALLBROOK AVE Ste. 220	91304	12	192B097   587	2005022006	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.22478	-118.62651	TENANT IMPROVEMENT ADD NEW LIGHTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21291	19041-10000-31935	333 S HOPE ST 14TH	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC for T24 only, scope of work is a TI for a office space remodel located in the 14th floor of a highrise. Scope of work includes new lighitng, cicuits, and controls. Total affected area is 5812 sqft. B# 19016-10000-25487	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21292	16041-20001-14708	13131 N MESA VERDE WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.31142	-118.40683	Expedited per applicant request.Plan check for a PV1 roof-mounted PV addition onto an existing system. PV system addition size is 3 kWac and consists of (1) inverter, (12) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21293	18041-20000-25385	2338 N HIGH OAK DR	90068	4	153B193   303	5587003016	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.11279	-118.31171	PV1.  Install 10.4 kW roof mounted grid tied PV system.  (32) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21294	16041-20000-04196	11945 N CAMEO PL	91344	12	216B133   464	2606017030	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Expired	03/07/2018 12:00:00 AM	ADDRESS	34.2868	-118.50677	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.89 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21295	13041-20000-09063	111 E UNIVERSAL HOLLYWOOD DR ste 2130	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	Plan check for energy and emergency lighting. Commercial high-rise, suite 2130. Hill International.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21296	13041-10001-27268	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	][] CHANGES TO AN APPROVED PLAN; CHANGES DUE TO THE ADDITION OF 11 SMOKE DETECTORS ][][INSTALLATION OF A NEW FIRE ALARM SYSTEM AND TO PROVIDE 24-HR SYSTEM MONITORING TO SPRINKLER SYSTEM IN SINGLE STORY BUILDING ( PLUS MEZZANINE). 101 DEVICES, 1 FIRE ALARM PANEL, 1 ANNUNICATING PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21297	13041-10000-22670	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	TENANT IMPROVEMENT FOR REMODEL OF AN EXISTING HISTORIC BUILDING.  SHELL AND CORE WORK.  NEW EXTERIOR FINISHES.  TITLE 24 PLAN CHECK ONLY FOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21298	18041-10000-27609	10654 N BALBOA BLVD	91344	12	207B133   586	2684001023	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Issued	07/24/2018 12:00:00 AM	ADDRESS	34.26387	-118.50206	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21299	13041-10000-16996	380 WORLD WAY 4115	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING ONLY FOR TBIT BRITISH AIRWAYS OFFICE. LOCATION IS AN EXISTING TENANT SPACE AND NOT A FIRST TIME TENANT PER APPLICANT.  FULL POWER PLAN CHECK SUBJECT TO INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21300	14041-20000-29708	10008 N LEV AVE	91331	6	204B153   864	2645011024	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.25238	-118.43532	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(18) SUNPOWER SPR327 MODULES(1) POWERONE PVI 6000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21301	16041-10000-04115	2330 S WALNUT AVE	90291	11	108B149    30	4242031008	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	33.99611	-118.45047	PV1, Install 6 kW AC roof-mounted solar array, interconnect with service panel. Transformerless (2)Inverter.: ABB PVI-3.6-OUTD-S-US-Z-A. (16) modules SILEVO TRIEX U290 BLACK	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21302	17041-20000-05041	837 N HARVARD BLVD	90029	13	141B193   201	5535031001	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Apartment			02/15/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Closed	06/28/2017 12:00:00 AM	ADDRESS	34.08587	-118.30419	Plan check for a fire alarm system for a 6-story, 65-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (194) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21303	16041-20000-45034	221 N FIGUEROA ST	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for energy only. TI to existing office on ground floor of existing high rise building. New lighting (incl. emergency) and receptacles. 12,037sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21304	13041-10000-04039	3133 S KERCKHOFF AVE	90731	15	006B197    89	7465027047	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	33.71543	-118.2899	PV1 2 STORY HOUSE.  3.36 KW INSTALLATION.  {14 MODULES: TRINA SOLAR TSM-240PA05} {TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US} POWER OPTIMIZER BEING USED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21305	12041-10000-26879	2376 N EDGEWATER TER	90039	13	148-5A209 458	5439006033	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM			Reviewed by Supervisor	11/19/2012 12:00:00 AM	ADDRESS	34.09953	-118.26007	2.86 kw roof mounted PV for a single family. (X-formerless INV with optimizer) PV1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21306	18041-20001-13148	845 S BROADWAY 1st Floor	90014	14	127-5A209 174	5144017038	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Info Complete	09/27/2018 12:00:00 AM	ADDRESS	34.04283	-118.25583	09-27-2018 Changes to an permitted set of plans with new updated floor plan. all changes under clouded area.All fee has been covered by original permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21307	16041-20001-04069	9301 N TAMPA AVE #93	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	3.30.2016 - Plan check for modifications of approved set. Change light fixture types and update T-24 calculations to reflect changes. Changes clouded Delta 2.===Plan check for Title 24 T.I. in existing space. Total area: 1,766 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21308	17041-10000-37192	5960 N CANOGA AVE	91367	3	177B105    79	2149002005	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.17881	-118.5972	REPLACING OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21309	11041-10000-12960	18700 W VENTURA BLVD #130	91356	11	174B121   811	2161026002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.17045	-118.54081	NEW CHIPOTLE RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21310	13041-20001-34542	5152 N TOPANGA CANYON BLVD	91364	3	171B101   861	2169005014	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.16331	-118.6056	EXPEDITE FEES ONLY.        <<<New rooftop PV system using DC-DC converters.  System is UNGROUNDED.  New subpanel and relocate 2 circuits.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21311	15041-10000-19261	501 S NEW HAMPSHIRE AVE	90020	10	135B197   767	5502023109	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			06/30/2015 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.06527	-118.29306	ADDITION OF WASHER AND DRYER COMBO TO AN EXISTING APARTMENT BUILDING 259 UNITS.    NEWLY CONNECTED LOAD > 400 AMPS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21312	13041-20001-31031	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.30155	-118.46112	((CHANGE INSULATION FROM THWN-2 TO XHHW-2))NEW DISTRIBUTION SECTION FOR EXISTING INSTALLATION. MANUFACTURING. NEW TRANSFORMER AND 600A RATED EQUIPMENT. PC FOR POWER ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21313	16041-20000-02682	525 S FLOWER ST 1st Level	90071	14	130-5A209 135	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM			PC Approved	01/25/2016 12:00:00 AM	ADDRESS	34.05109	-118.25696	Plan check for Title 24 only for existing high-rise building in Lobby/Plaza. Total area indoor + outdoor: 17,846 sq ft.(12/5/2016)THIS IS PLAN CHECK ONLY.MASTER PERMIT TO BE UNDER APPLICATION NUMBER 16041-20001-02682	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21314	16041-10000-41590	6949 N LUBAO AVE	91306	3	183B113   508	2135025014	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.19705	-118.56783	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.6KWdc / 6.0KWac.(24)MODULES-SOLARWORLD 275 MONO BLACK(1)INVERTER-SMA SUNNYBOY 6000TL-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21315	18041-20002-48748	8218 N WILKINSON AVE	91605	2	192B165   630	2308020004	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.22051	-118.40401	05-24-2019 Changes to an approved set of plans, Changes include replace PV Module with higher wattage rating from325 W to 330 W and increase inverter size to 10.0KW with 31 PV Moduels.  All Changes has been clouded. New PV system size: 10.23KW and 27KW Energy Storage System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21316	14041-20000-35053	10370 N PATRICK AVE	91331	6	204B153    84	2617019020	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.25931	-118.44055	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). Ungrounded system.26  327W pv modules across 4 strings (inv1 has 9+4; inv2 has 8+5).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21317	14041-10001-28484	1034 S CATALINA ST	90006	1	129B197   357	5078012017	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	34.05171	-118.29462	EXPEDITED PER APPLICANTS REQUESTNegatively grounded PV2 system.25.5 KW roof-mounted system including (5) Delta Solivia 5.2TL  inverters, and (104) LDK 280P-24 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21318	14041-10000-13895	13604 W SHERMAN WAY	91405	2	183B157    75	2328008008	(T)(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			05/23/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.20102	-118.4293	PcC for power and energy. New 5-story 65 unit affordable housing. Total area (indoor) 14520 sq ft and 20925 sq ft (outdoor). Solar array has to be installed on the bulding with different application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21319	18041-10000-35987	1030 N SWARTHMORE AVE 3-108	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	"First time retail tenant space ""BonJour"" in Suite #3-108.Full plan check for power and energy.  845 Sqr Ft.Bldg Permit# 18016-10000-28551"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21320	18041-20000-36240	15347 W SUTTON ST	91403	5	166-5A145 251			South Valley				1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Issued	09/21/2018 12:00:00 AM	ADDRESS	34.15035	-118.46903	Plan check for a PV1 roof-mounted PV system. System size is 5.8 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21321	10041-10000-17364	8500 W BEVERLY BLVD K-604&630	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	12/02/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI-EXISTING  RESTAURANT LOCATED WITHIN THE BEVERLY CENTER  MALL - (N) BAR, PREPAREA, WOMEN'S TOILET & SEATING.  NEW CANOPY OVER BAR (E) REMOTE MEN'S RESTROOM & REMOTE FOOD PREP/STORAGE TO REMAIN UNCHANGED. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21322	13041-20000-30599	5123 N BLUEBELL AVE	91607	2	171B161   718	2357001014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.16371	-118.41065	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 19.6 KW AC USING 78 MODULES. USING 4 TRANSFORMERLESS INVERTERS. A SUBPANEL. 400A SERVICE. ((($0 permit fee is due to the 2012 Senate Bill No. 1222)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21323	13041-10000-25575	1555 S RIO VISTA AVE	90023	14	120A219    53	5169010012	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.02187	-118.22234	Remove HID light fixtures and install new flourescent lights.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21324	16041-20002-44588	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.23342	-118.3809	8/9/17 Changes to approved set of plans.  Change to motor conductor sizing details.  PC FOR POWER. INSTALLATION OF COMPRESSED NATURAL GAS COMPRESSION AND FUELING DISTRIBUTION SYSTEM. SERVICE UPGRADE 3000A. HAZARDOUS AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21325	10041-20000-09841	461 S BOYLSTON ST 5th st	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.05463	-118.25943	CHILLER ADDITION AT 5TH STREET BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21326	15041-10000-04922	625 N BROAD AVE	90744	15	030B205   692	7423001030	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	33.77795	-118.2612	Installation of new roof mounted solar PV array.  Total system size = 4.2 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21327	14041-20000-24357	13849 W MONTAGUE ST	91331	6	195B153   652	2640015029	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.23056	-118.4349	PV1.  Install 3.924 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21328	10041-10000-14271	530 W 6TH ST 7TH FLOOR	90014	9	129A209    78	5144004012	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	12/21/2010 12:00:00 AM	ADDRESS	34.04853	-118.25518	TI IN AN EXISTING COMMERCIAL AREA IN THE NETWORK/IT ROOM OF THE 7TH FLOOR. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21329	14041-20001-02402	8532 N VAN NUYS BLVD	91402	6	192B149   107	2638001043	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.2257	-118.44884	Change from previously approved plans.  Change include new occupancy sensors, relocate swtiches and lighting fixtures.  Plan check for energy only.Note: Permit issued under application 14041-20000-02411*****T24 FOR EXISTING OFFICE SPACE.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21330	17041-20000-12070	7501 N GLENOAKS BLVD	91504	2	186B181   296	2401042013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.04	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	04/13/2017 12:00:00 AM	ADDRESS	34.20677	-118.34209	ti to an existing hotel.  adding new lighting new controls to new panels.  newly connected load less than 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21331	18041-10001-19649	5684 E YORK BLVD	90042	14	154-5A229 114	5478035002	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	34.11876	-118.19402	delta 1 change to an approved t-24 set. change include modifying corridor and office/storage light layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21332	15041-20000-39378	20790 W NORDHOFF ST Space 3	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	TI for (E) commercial space for new 1208 sq ft yogurt shop.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21333	14041-20000-06358	16739 W ADDISON ST	91436	5	171B137   216	2259003021	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.16315	-118.49819	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 CENTRAL INVERTERS WITH ISOLATION TRANSFORMER. CONNECTED TO 400A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21334	11041-10000-02065	3833 S CRENSHAW BLVD	90008	8	117B185   719	5045019900	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	12/04/2012 12:00:00 AM	ADDRESS	34.0162	-118.33546	ADD 1416 SF   2ND FLR ADDITION AND TI FOR ADULT EDUCATION.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21335	15041-20000-02777	12476 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	33.97888	-118.41041	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21336	19041-20000-46492	1244 S LONGWOOD AVE	90019	10	129B181   289	5083019025	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.05199	-118.34056	Installation of 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21337	18041-10000-38358	11500 W CULVER BLVD	90066	11	111B161   528	4217016001	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			10/09/2018 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	02/04/2022 12:00:00 AM	ADDRESS	34.00003	-118.4134	FULL PLAN CHECK FOR A NEW 4-STORY, 15-UNIT, 7-TYPICAL  UNITS APARTMENT WITH ROOF DECK & PARKING GARAGE. 800AMP SERVICE, 120/240 DELTA SYSTEM. . TOTAL SQ. FT. 12710.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21338	17041-10001-12385	360 N STONE CANYON ROAD	90077	5	141B153   173	4362013015	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM			PC Approved	08/03/2018 12:00:00 AM	ADDRESS	34.08078	-118.44249	[[8/3/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ONLY. CHANGES TO J-BOXES AND NOTES]]]ELECTRICAL DESIGN FOR NEW SFD. PERMIT ISSUED UNDER BUILDING COMBO, THIS IS PLAN CHECK ONLY. B#08010-10000-00426	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21339	13041-10001-32357	11347 W SUNSHINE TER	91604	2	162B173   682	2378020011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.13926	-118.37703	Expedited RSES plan check per applicant request.(((PV1, Install 8.25 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 33 modules module Yingli YL250P-29b.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21340	14041-20000-20168	22007 W LANARK ST	91304	3	189B101   123	2012001***	(Q)RD3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.21686	-118.60645	pv1 single family dwelling. total system size 4.2 kw ac using 16 modules and microinverter enphase m215. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21341	11041-10000-16204	21618 W ROSCOE BLVD	91304	3	192B105   618	2110019031	[Q]CM-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.21957	-118.60091	T.I.  Exsting 7-Eleven.  Rennovating the light fixtures in the retail are only.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21342	13041-10000-26010	12855 W RUNWAY ROAD BLOCK 1	90094	11	102B157   395	4211033036	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/03/2013 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	33.97556	-118.41956	PLAN CHECK FOR POWER AND ENERGY. THIS IS BLOCK 1 OF PLAYA VISTA PROJECT. ELECTRICAL INSTALLATION FOR MULTI-FAMILY 4-STORY OVER PODIUM; 3 SERVICES (SERVICE 1,2,3), LOCATED IN METHAN ZONE, LEVEL-5.  2 GENERATORS INSTALLED. TOTAL 309 UNITS. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM FROM PLAN HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21343	13041-20000-00377	5053 N CARTWRIGHT AVE	91601	2	171B177  1032	2419011006	R2-1VL, RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Expired	02/26/2015 12:00:00 AM	ADDRESS	34.16261	-118.36384	PV system on roof of commercial building using transformerless inverters.  A 15 ampere fuse  is to be installed in the positive and negative circuit at the inverter fuse box.  No grounding of the DC circuit is allowed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21344	18041-10001-28148	1030 N SWARTHMORE AVE #2-106	90272	11	129B125   468	4423016025	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			Reviewed by Supervisor	11/15/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Full plan check for a lost of plan. Permit fees are under master application. 18041-10000-28148(((Full plan check for first time to existing retail space within Pacific Palisades Village. New step down transformer and 100A panelboard for the tenant for lightings and power. Total area: 563 sq.ftB# 18016-10000-23722)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21345	13041-10000-00184	570 N FIGUEROA ST	90012	1	135A213   382	5407003036	C2-2D	Central	Central City	Historic Cultural		2071.00	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.06226	-118.24625	T.I.  Existing convinience store located on the first floor.  Remodel of the interior light fixtures.  PLan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21346	17041-10000-36840	250 S GRAND AVE	90012	14	130-5A211 190	5149010***	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.05328	-118.25074	REPLACE EXISTING FIXURESWITH LED FIXURES-TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21347	13041-20000-21243	10100 W SANTA MONICA BLVD STE 410	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for energy and emergency lighting. Commercial high rise. 4th floor suite 410. Plenary Group.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21348	18041-10000-27316	1702 W JEFFERSON BLVD 1-3	90018	8	120B193   752	5041003037	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Apartment			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	07/10/2021 12:00:00 AM	ADDRESS	34.02527	-118.3061	PC FOR NEW FIRE ALARM IN AN APARTMENT BUILDING (3 UNIT 2 STORY)SCOPE INCLUDES FACP AND 12 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21349	10041-20000-24915	1055 W 7TH ST 5th, 7th-12th floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.0507	-118.26334	T.I. to existing high rise building of 5th floor and 7th thru 12th floors.  Install news panels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21350	16041-20000-36378	4876 N LANKERSHIM BLVD	91601	2	168B173   199	2353019008	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.15962	-118.37125	remove hid fixtures and replace with new led fixtures outdoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21351	12041-20000-03687	127 S SAN VICENTE BLVD Bulletin-141 TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM			PC Approved	02/29/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin-141 TI REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21352	17041-10001-23807	902 S 4TH AVE	90291	11	108B145   604	4239010022	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			07/14/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	33.99368	-118.47158	SUPPLEMENTAL FOR OFF HOUR PLAN CHECK PERMIT WORK DESCRIPTIONPV2. NEW ROOF MOUNTED SOLAR SYSTEM FOR AN EXISTING MULTI-FAMILY RESIDENTIAL. TOTAL SYSTEM SIZE IS 3.0KWac.(7)MODULES-TRINA SOLAR#TSM-300DD05A.18(1)INVERTER-ABB#PVI3.0-OUTD-S-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21353	16041-10000-45568	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			01/09/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.06047	-118.29555	PC FOR ENERGY AND POWER. ADDITION OF 5 STORIES ( APARTMENT/GARAGE )ON TOP OF AN EXISTING 3-STORY TYPE I PARKING STRUCTURE TO CREATE 8-STORY 120 UNITS APARTMEN/GARAGE BUILDING. FED FROM EXISTING  SERVICE FROM ANOTHER BULDING WITH DIFFERENT ADDRESS PER DWP . (E) 5000A, 480/277V, MAIN SWITCHGEAR 2000A,480/277V, 3 PHASE, 4W. TOTAL AFFECTED AREA IS 120923 SQ. FT. B# 15014-10000-05720	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21354	17041-20000-31519	700 S FLOWER ST Suite 750	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,673 sq. ft.Note: Building application has been generated under 17016-10000-23776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21355	17041-10001-03199	20050 S VERMONT AVE	90502	15	057B197   154	7351033062	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	33.84838	-118.29024	12-15-2017 Changes to an approved set of plans. Changes include reduce size of conductor from 400kcmil to 4/0 for LE panel. Changes has been clouded as delta 2. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21356	12041-10000-12916	4700 S CENTRAL AVE	90011	9	112-5A209 316	5107016001	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	08/07/2012 12:00:00 AM	ADDRESS	34.00099	-118.25628	New 600 Service and panel board for connection to 6 state approved trailers and circuits for outdoor lighting.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21357	19041-10000-49069	15271 W PALISADES VILLAGE LANE 2-118-2-203	90272	11	129B125   863	4423016078	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	34.04774	-118.52461	Energy plan check only for T.I. to existing office. Affected area (5728)SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21358	17041-10000-16218	2911 S OVERLAND AVE	90064	5	123B161   599	4255011017	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.0335	-118.41874	PC for energy only. Outdoor Title-24. Removing existing fixtures and adding new LED lights. Area: 9150sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21359	18041-10000-44906	5791 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	33.93414	-118.3839	REPLACE FLUORESENT TROFFERS WITH NEW LED RETROFIT KITS & REMOVE INDOOR/OUTDOOR HID FIXTURES TO REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21360	14041-10001-14927	9723 N COLUMBUS AVE	91343	7	201B145   420	2656005016	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/16/2014 12:00:00 AM	ADDRESS	34.24727	-118.46543	Expedite fees only.Install roof mounted solar array.2 Inverters with output = 4.2 kW each	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21361	18041-10000-28141	777 S SANTA FE AVE	90021	14	124-5A217 323	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	FULL PLAN CHECK FOR TENANT IMPROVEMENT TO 1ST AND 2ND FLOORS OF OFFICE/ SPACE; INSTALL NEW PANELS, CIRCUITRY, LIGHTING AND POWER. TOTAL AREA UNDER THE SOW: 30,995 SQ.FTB# 18016-10000-22178	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21362	17041-10000-30506	1301 W STORM PKWY	90501	15	045B197    71	7347018033	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	33.81706	-118.29917	Plan check for Titel 24 only in existing space.  replace existng fixtures with LED fixtures. Total area: 32,250 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21363	10041-20002-18168	7250 W FRANKLIN AVE 1st floor	90046	4	147B181    21	5548025***	R3-1	Central	Hollywood	Hollywood Hills West	YES	1899.03	Electrical	Electrical	Apartment			09/14/2011 12:00:00 AM			PC Approved	09/14/2011 12:00:00 AM	ADDRESS	34.10329	-118.34724	Plan check for revision to approved plans. The revision is the removal of the time clock that was to control the Lobby, mail room, and package room.  The changes have been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21364	15041-10001-33858	20350 W VENTURA BLVD	91364	3	171B113    28	2166035030	(Q)CR-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.16881	-118.57601	Expedited per customer request. (((PV2, ROOF MOUNTED SOLAR SYSTEM TO AN (E) OFFICE BUILDING. (160) MODULES AND (6) INVERTERS. (160) CANADIAN SOLAR CS6X-315P(3) SMA SUNNY BOY SB900TL-US(3) SMA SUNNY BOY SB7000TL-US)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21365	19041-20000-30978	14842 W LEMAY ST	91405	6	180B149   280	2236005013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.19186	-118.45667	Plan check for energy storage system, Energy storage size: 27KWh. 2 Tesla Power Wall2.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21366	15041-20000-37019	8124 N AGNES AVE	91605	6	189B165    75	2310012005	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Expired	12/04/2017 12:00:00 AM	ADDRESS	34.21823	-118.39538	PV1, roof mounted solar panel, 4.24kW system(22)modules: #KU2656ZPA(1) INVERTER: pvi-5000-outd-s-usStandrad plan is used	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21367	16041-20001-04082	17331 W CUMPSTON ST	91316	5	174B133   784	2257011014	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.16954	-118.51117	expedite per applicant request(((((plan check for PV roof mounted system. System size 9.6 kW with 40 PV modules and 40 microinverters connected to 400 A panel.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21368	17041-20000-42738	3231 N STEVEN DR	91436	5	159B141   212	2293014019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	05/14/2018 12:00:00 AM	ADDRESS	34.13339	-118.48222	$0 permit fee per State Senate Bill SB 1222.PV1.  Install roof mounted PV system sized 13.8kW interconnected with MSP.  (52) modules with 10kW and 3.8 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21369	10041-20000-16595	3601 S TROUSDALE PKWY #311	90089	8	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Expired	11/30/2012 12:00:00 AM	ADDRESS	34.02017	-118.28558	Plan check T-24 Energy general/emergency lighting for USC Student Union #311. Work in existing ckts, new ckts, and low voltage relay cabinet and devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21370	11041-20000-06983	8900 N DE SOTO AVE	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.23162	-118.58832	T.I. to existing building.  Install general lighting in conference and office rooms.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21371	14041-10001-00517	114 E 2ND ST	90012	14	130-5A213 205	5161026033	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM			PC Approved	08/07/2014 12:00:00 AM	ADDRESS	34.05056	-118.24413	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO RESTAURANT, PREVIOUSLY A CHURCH. (((((((   8-7-14   reduction of few lights and new title 24.)))))))))))))))))))))building p# 13016-10000-09572	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21372	15041-10000-39949	8631 W 3RD ST #1100E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.07373	-118.38036	TI TO EXISING OFFICE SPACE. NEW LIGHITNG. NEW PRIVATE OFFICE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21373	18041-10000-19241	3243 S LA CIENEGA BLVD	90016	10	123B173  1679	4205035002	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Closed	01/26/2024 12:00:00 AM	ADDRESS	34.02892	-118.3739	PC FOR TENANT IMPROVEMENT TO EXISTING MANUFACTURE SPACE FOR TITLE 24 ENERGY ONLY.. TOTAL AFFECTED AREA SQ.FT 4860.SCOPE INCLUDES NEW LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21374	12041-10000-12765	757 W SEPULVEDA ST #B	90731	15	018B197   684	7447031017	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	33.74551	-118.29354	New 1kw, rooftop photovoltaic system for an existing duplex.  System uses Enphase M215 micro-inverters.  Each unit has a separate service drop, per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21375	16041-10000-09565	13368 W BEACH AVE 1-21	90292	11	108B153   847	4230007268	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			03/18/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Closed	07/14/2016 12:00:00 AM	ADDRESS	33.99147	-118.44362	PV2, rooftop solar installation on (E) 21 unit apartment. (15) LG310N1C   (1) FRONIUS SYMO 10.0-3 240* PLAN IS APPROVED BY FA DEPT. #C16-00890** RTI ISSUED UNDER BUILD. DEPT. #16016-10000-03388	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21376	15041-10000-05291	1016 S FRESNO ST	90023	14	121-5A225 115	5188024900	OS-1XL	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.02721	-118.20702	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  CHANGES TO EXISTING LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 5828	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21377	18041-10000-43889	14707 W KESWICK ST	91405	6	189B149   542	2210025010	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.21049	-118.4533	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21378	16041-20000-38038	13651 W FILMORE ST	91331	7	207B157   371	2619011016	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.26559	-118.43022	PV1.  Install 8.6 kW roof mounted grid tied PV system.  (32) panels with Enphase M215 microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21379	16041-10000-25803	10700 W SANTA MONICA BLVD #130	90025	5	129B157   367	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Issued	07/28/2016 12:00:00 AM	ADDRESS	34.05167	-118.432	Plan check for T-24 only. TI to an exitring hair salon, install new lights and receptacles. Total affected area: 1055 sq.ftB# 16016-10000-14305	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21380	13041-10001-28784	2123 S BEVERWIL DR	90064	5	126B165    35	4309003006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	PIN	34.04535169	-118.39926568	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. 2 STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE: 9kW DC. TRANSFORMERLESS , UNGROUNDED.(36) TRINA SOLAR # TSM-250(1) POWERONE # AURORA PVI 3.6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21381	15041-20001-26937	12954 W CORCORAN PL	91340	7	216B161   108	2514010050	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.28959	-118.41511	Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  Single inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21382	19041-20000-49570	1328 N DUENDE LANE	90272	11	132B121   130	4420028004	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.05966	-118.54802	PV1. INSTALL 11.88 KWDC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21383	17041-10001-17090	333 S GRAND AVE STE# 3570	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR CHANGES TO APPROVED SET. CHANGES NOTED DELTA 2 ON PLANS. REMOVAL OF A ROOM AND UPDATED FLOOR PLAN. PROVIDED UPDATED T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21384	14041-20000-34167	20969 W VENTURA BLVD	91367	3	171B109    73	2167001013	C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	PIN	34.16701214	-118.59032578	TI to (E) restaurant commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21385	10041-10000-00633	1730-1732 S SEPULVEDA BLVD	90025	5	129B153   931	4323020005	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/13/2010 12:00:00 AM			Corrections Issued	01/13/2010 12:00:00 AM	ADDRESS	34.04681	-118.44338	Plan check 2008 T-24 energy ( general/emergency lighting) for a TI Veterinary space in existing space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21386	10041-10000-15142	2212 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	09/22/2010 12:00:00 AM		Permit Finaled	10/19/2010 12:00:00 AM	ADDRESS	34.03786	-118.44074	TI IN AN EXISTING RESTAURANT (WHICH WHICH?).     EXISTING SERVICE AND PANELS.    PLAN CHECK IS FOR TITLE 24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21387	14041-20000-28341	10010 N REMMET AVE	91311	12	204B105   820	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			Reviewed by Supervisor	10/22/2014 12:00:00 AM	ADDRESS	34.25239	-118.60035	INSTALLATION OF NATURAL GAS FUEL DISPENSER. PLAN CHECK FOR HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21388	16041-20000-10280	970 W 190TH ST Suite 300	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	33.85812	-118.29302	Plan check for energy only. TI to existing office in high rise office building. New lighting (incl. emergency) and receptacles. 2,311sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21389	13041-10002-12139	9301 N TAMPA AVE #218	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	CHANGES MADE TO AN APPROVED SET OF PLAN; TITLE-24 PLAN CHECK ONLY FOR NEW RESTAURANT TI- BONEFISH GRILL. SUITE #218 . CHANGES INCLUDES 120V LINE LIGHTING TO LOW-VOLTAGE THROUGHOUT ENTIRE DINING AREA. LIGHTING FIXTURES HAVE BEEN RELOCATED . NEW LUMINAIRES ARE ADDED. ENTIRE LTG COMPLIANCE FORMS IS MODIFIED TO REFLECT THE VARIOUS CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21390	14041-20000-29059	3541 N WESTFALL DR	91436	5	159B137    92	2293008005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.13539	-118.49314	PV1 Install roof-mounted solar array, interconnect with MSP. 2 inverters, system size 9.2kW. 50 255W pv modules across a total of 4 strings. 400A main service.Note: Permit fee $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21391	14041-20001-10472	4507 N ATOLL AVE	91423	4	165B157    64	2360027021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.15241	-118.42053	(((expedite fees))))pv1 single family dwelling. total system size 6.4kw ac using microinverter enphase m215. nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21392	19041-20000-06737	6477 W FOOTHILL BLVD	91042	7	201B205   639	2571015044	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1013.00	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.24471	-118.2727	new carwash 800 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21393	19041-20000-28683	625 N KINGMAN AVE pv1	90402	11	124-5A133 153	4408034023	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Issued	08/12/2019 12:00:00 AM	ADDRESS	34.03507	-118.50885	install roof mounted pv system sized 4.9KW AC , 5.025KW DC with 15 PV Modules and 15 microinverters interconnected with msp.(1) tesla ESS rated at 5KW, 13.5KWh	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21394	14041-10000-11957	380 WORLD WAY T-64	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Install illuminated signage not visible from ROW. (Scoreboard LA)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21395	15041-10002-08987	380 W WORLD WAY Terminal 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	12/22/2015Changes to an approved set of plans, note changes on delta 4. Changes include addition and removal of devices. ((8/6/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3. CHANGES INCLUDE REMOVAL AND ADDITION OF DEVICES.New fire alarm system (full evacuation) for Terminal 4 connector on levels 1-4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21396	19041-10000-45907	1253 N BISHOPS ROAD	90012	1	136-5A215  10	5414019011	[Q]R3-1	Central	Central City North	Historic Cultural North		2060.10	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	06/25/2020 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	34.06976	-118.23428	0$ FINAL FEES PER AB1414THIS IS SYSTEM 1 OF 2PV2, NEW COMMERCIAL ROOFTOP MOUNTED SYSTEM, OVERALL SYSTEM SIZE IS 255.8KWdc/173KWac. SCOPE OF WORK IS TWO PV SYSTEMS. PERMIT FOR SYSTEM ONE IS UNDER 19041-10000-45907PERMIT FOR SYSTEM TWO IS UNDER 20041-10000-21239SYSTEM ONE IS A 140KWac SYSTEM CONSISITING OF 425 MODULES (HANWHA 390), WITH OPTIMZERS (SEP850) FIVE CENTRAL INVERTERS (FOUR SMA STP 30000, ONE SMA STP 20000,), ALL LEADING TO TWO SUBPANELS, AND A BATTERY BANK AT 30KW. CONNECTED TO AN EXISTING 2000A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21397	17041-10000-25778	921 S CATALINA ST	90006	10	132B197   967	5094023009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.05507	-118.29553	PC FOR ROOF MOUNTED PV ON SFD.SYSTEM SIZE 8.280 KWACTOTAL 24 AC MODULE	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21398	18041-20000-32021	11611 W SAN VICENTE BLVD	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.0541	-118.46261	Plan check for power only. Project site is an existing commercial building. Project scope is the replacement of a damaged 1,600 amp distribution section and new distribution equipment. All loads existing and re-fed from new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21399	10041-20000-06502	1920 E MARENGO ST	90033	14	132A223    49	5201016023	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2036.00	Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.05739	-118.20965	Extrior lighting ( parking lot light . & future undergroud conduit )Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21400	19041-20001-32437	11380 N ETIWANDA AVE	91326	12	213B125   510	2870013027	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.27797	-118.5328	9/17/19 CHANGES TO APPROVED SET DELTA B CHANGES TO CONDUIT RUN ON THE ROOF.<<<PV1. INSTALL 7.59 KW DC/ 6 KW AC ROOFMOUNTED SOLAR SYSTEM AND (1) 6KW INVERTER ON EXISTING 200 AMP SERVICE.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21401	13041-10001-01885	380 WORLD WAY Space T50	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Delta 3 revisions- replaced track lighting with other track system with lower wattage; compliance forms were updatedLAX  Thomas Bradley International  Terminal level 4. space T50-RPROPOSED 1470 SQFT.  TENANT IMPROVEMENT  FOR RETAIL CONCESSION  SPACE (kitson).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21402	17041-20000-39617	110 W 11TH ST 350	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.0392	-118.25858	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 3RD FLOOR, SUITE 350. 1985 SQFTBUILDING P# 17016-10000-12320	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21403	18041-10001-40903	9401 N DE SOTO AVE	91311	12	198B109    69	2746008007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.24091	-118.58876	EXPEDITE PER APPLICANT REQUEST(((IINSTALLING 999.9 KWAC ROOFTOP PV SYSTEM, ON EXISTING WAREHOUSE3152 MODULES, 10 (50.1-100KW) INVERTERS, 2 1600A PANELS, 90 BRANCH CIRCUITS)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21404	16041-20000-26073	23155 W DOLOROSA ST	91367	3	174B093   425	2042003075	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.17022	-118.63168	PERMIT FEE $25.92 STATE SENATE BILL NO. 1222Plan check for PV roof mounted system. System size: 11.5kW with 53 modules and 1 inverter(11.5kW) connected to 400A Service	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21405	12041-10000-24262	5825 W SUNSET BLVD suite  203	90028	13	147A191    51	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.09824	-118.3165	remodel small office space in a commercial buildingplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21406	13041-10003-22769	3000 W 6TH ST	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	PIN	34.06351748	-118.28745252	PV2.  Redesign of proposed commercial PV system of 13041-10000-22769.  Additional fees and submittal.  PV2. ROOF MOUNTED PV INSTALLATION. SYSTEM SIZE: DC RATING 27.54 KW. AC RATING 23.4.  TRANSFORMER INVERTER).   To issue permit print > Inspection <.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21407	16041-20000-41004	10259 ANGEL LANE	91331	7	204B165   439	2537004049	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25703151	-118.40490945	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21408	13041-20000-23804	6821 N ENCINO AVE	91406	6	183B129  1022	2229004017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.19453	-118.51434	PV1 TRANSFORMERLESS SYSTEM. 17 MODULES AND 1 INVERTER. 4.165 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21409	15041-10000-32551	11601 W WILSHIRE BLVD 23RD FLR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	PIN	34.0509267	-118.45996763	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUAREFOOTAGE 17355. SCOPE OF WORK TO BE ON THE 23RD FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21410	15041-10000-28833	11801 N PORTER RANCH DR	91326	12	216B113     1	2701002069	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Info Complete	09/01/2015 12:00:00 AM	ADDRESS	34.28376	-118.5714	PC for Energy only, Hardscape 264 sq.ftinstalled 4 luminaires for entry lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21411	18041-10001-21268	12566 W ROSE AVE	90066	11	117B153  1130	4247023014	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.01336	-118.44443	EXPEDITED FEESPV1, ROOF MOUNTED SOLAR SYSTEM USING MICRO INVERTERS. TOTAL (10) MODULES AND (10) IQ6 MICROINVERTERS. TOTAL SYSTEM SIZE IS 2.4KWAC AND 3KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21412	19041-10000-22666	19126 W LIGGETT ST	91324	12	198B121   350	2762018025	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.24025	-118.55007	Plan check for a 3.72kw DC / 3.80KW AC roofmounted system with 12-modules, (1) inverter interconnecting through the main service panel. Note. PV module from GAF is INTERGRATED AS PART OF THE  ROOFING SYSTEM. BUILDING AND FIRE CLEARANCE MAY REQUIRED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21413	17041-10000-09588	221 N FIGUEROA ST 15TH FLR	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.05882	-118.25099	T-24, PC FOR ENERGY ONLY. INTERIOR TI FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE FOR THE 15TH FLOOR. TOTAL AFFECTED AREA IS 451 SQ. FT. B#17016-10000-03344	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21414	12041-10000-06701	8616 S LA TIJERA BLVD	90045	11	096B169   586	4123004008	[Q]C2-1VL-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	06/01/2012 12:00:00 AM	ADDRESS	33.95933	-118.39173	New outdoor lighting for a parking lot.  10.7A of load.  49,080 square feet of Energy.  PLAN CHECK ONLY for Energy.  Permit fees are under inspection for new circuits and transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21415	19041-10000-48262	4330 N IRVINE AVE	91604	2	165B169   499	2365025023	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	PIN	34.14826668	-118.38523399	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 31 MODULES (LG320N1K-A5) , 31 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE7600H-US).  SYSTEM SIZE IS 9.920KWdc and 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21416	18041-10000-20695	345 S COLUMBIA AVE	90017	1	133-5A207 270	5153019027	R4-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.05874	-118.26513	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21417	16041-10000-19530	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/03/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	Plan check for Title 24 only in existing space roof of the building.   Total area: 3485 sq ft. BUILDIG  PERMIT # 14016-10002-03486	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21418	12041-20000-10410	617 W 7TH ST	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM			Corrections Issued	11/13/2012 12:00:00 AM	ADDRESS	34.04779	-118.2571	TI remodel for office. 13061 sft. High rise commercial building. 4th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21419	17041-10000-14416	647 S TOWNE AVE	90021	14	126A213   184	5147027004	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.04032	-118.24469	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new led ones. Area: 13,875 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21420	12041-20000-06192	18000 W DEVONSHIRE ST	91330	12	204B125   310	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Expired	04/16/2012 12:00:00 AM	ADDRESS	34.25313	-118.52557	office T.I.Energy, emergencyTI TO (E) OFFICE SPACE TO PUT NEW NON LOAD BEARING PARTITIONS 9 12016-20000-05236 ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21421	12041-10000-07582	10100 W SANTA MONICA BLVD 11th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM			PC Approved	04/20/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	T.I. to the 11th floor (restrooms and elevator freight lobby are on a separate application)  of an existing office building.  Changing lights,  new receptacles.  Load is 197A  and occupancy is less than 99 occupants,  per applicant.  (May require full plan check if load is over 400A, per field inspection.)  PLAN CHECK ONLY for T-24, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21422	19041-10000-33060	6309 N LANKERSHIM BLVD	91606	2	177B169   119	2335031021	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	08/25/2021 12:00:00 AM	ADDRESS	34.18511	-118.38706	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO (E) RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3041 SQ. FT. B#19016-10000-21564	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21423	14041-10000-24947	3621 S ROSEWOOD AVE	90066	11	111B149   282	4245011016	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.00295	-118.44623	PV1, INSTALL 2.295 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(9) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-UNote: the solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21424	18041-10000-16301	5637 W LEXINGTON AVE	90038	13	144B193   365	5536004031	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			05/25/2018 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	02/09/2021 12:00:00 AM	ADDRESS	34.09289	-118.31218	PC FOR NEW 4-STORY, 37-UNIT AFFORDABLE HOUSING (3 VERY LOW INCOME UNITS) APARTMENT BUILDING; 3-STORY, TYPE VA RESIDENTIAL OVER 1-STORY, TYPE 1A PARKING GARAGE;SCOPE INCLUDES NEW SERVICE 1600 120/208V.TOTAL SQ. FT  32000B#17010-10000-02631	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21425	13041-10000-24753	18609 W COMMUNITY ST	91324	12	192B121   480	2785015030	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.22306	-118.53855	PV1. INSTALL 4.9 KW DC ROOF MOUNTED SOLAR ARRAY OF 20 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS. DC UNGROUNDED WITH POWER OPTOMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21426	17041-10000-22627	420 E CULVER BLVD	90293	11	096B149   175	4116010044	[Q]C4-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	33.961	-118.44556	T24 COMPLIANCE FOR SIGN LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21427	16041-20001-18091	5971 W VENICE BLVD	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.03865	-118.37272	10/27/2016 Changes to an approved set of plans. Changes have been made to the fixture type. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Plan check for carport lighting.  50,116 sq ft of hardscape lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21428	17041-10000-16731	2735 N LA CUESTA DR	90046	4	156B177   679	5570002001	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			Reviewed by Supervisor	05/31/2017 12:00:00 AM	ADDRESS	34.12104	-118.35657	Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  Two new 5.2 kWac inverters connected to 125 amp load center.  New AC coupled 5.8 kVA / 13 kWH battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21429	18041-10000-43843	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			Reviewed by Supervisor	11/26/2018 12:00:00 AM	ADDRESS	34.18421	-118.60617	PLAN CHECK FOR POWER AND ENERGY FOR SHELL OF EXISTING SPACE - SCOPE INCLUDES REPLACEMENT OF EXISTING DISTRIBUTION SYSTEM CONNECTED TO AN EXISTING SERVICE WITH ASSOCIATED EQUIPMENT - TOTAL AFFECTED AREA = 32816 INCLUDES BOTH REG/EMERGENCY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21430	19041-10000-40757	13361 N GLENOAKS BLVD	91342	7	225B145   449	2501022078	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	06/29/2021 12:00:00 AM	ADDRESS	34.3146	-118.45921	$0.00 fees due to senate bill 1222 and 1414 Plan check for a PV2 53.3KW AC / 54.7KW DC roofmounted system with (1) load center, (2) inverters, (152) modules and (76) optimizer interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21431	18041-10000-36453	13526 W VENTURA BLVD	91423	4	165B157   762	2373009007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Issued	09/25/2018 12:00:00 AM	ADDRESS	34.14731	-118.42796	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21432	16041-10000-37601	4715 N HEAVEN AVE	91364	3	168B093   198	2074040002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Issued	11/09/2016 12:00:00 AM	ADDRESS	34.15661	-118.63216	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.099KWac / 11.00KWac.(37)MODULES-SUNPOWER SPR327NE-WHT-D(1)INVERTER-SUNNYBOY SMA SB6000TL-US-22(1)INVERTER-SUNNYBOY SMA SB5000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21433	18041-20000-18917	5400 N BALBOA BLVD	91316	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM			Corrections Issued	05/22/2018 12:00:00 AM	ADDRESS	34.1692	-118.50087	Plan check for Title 24 only. Project site are the common areas to  an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,765 sq. ft.Note: Building application has been generated under 18016-20000-15145	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21434	19041-10000-05806	3800 S VERMONT AVE	90037	9	117B197   615	5037028912	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Closed	12/12/2023 12:00:00 AM	ADDRESS	34.01684	-118.29134	PC FOR A FIRE ALARM SYSTEM FOR THE LUCAS MUSEUM.  SCOPE INCLUDES A 963 FA DEVICES, AND 5 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21435	15041-20000-39703	13650 W BURBANK BLVD	91401	4	174B157   611	2344001014	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.17196	-118.43072	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM (E) RETAIL TO (N) BEAUTY SALON.  866 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21436	14041-20000-10886	8608 N ORION AVE	91343	6	192B145    14	2654030011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Expired	05/19/2016 12:00:00 AM	ADDRESS	34.22685	-118.47191	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL TRANSFORMERLESS STANDARD PLAN. SYSTEM SIZE: 4 KW.(16) CANADIAN SOLAR CS6P 250(1) POWER ONE AURORA PVI 3.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21437	17041-20002-46480	10936 N SHARP AVE	91345	7	210B149  1139	2615028020	RA-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.26862	-118.44755	supplemetal to changes to approved set of plans to relocate lods from load center panel to main panel. Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.7.6kW ungrounded pv system. (29) 325W pv modules. (29) 400W power optimizers.(2) 5kW Tesla Powerwall 2s.$17.93 permit fee per State Senate Bill SB 1222.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21438	14041-20001-05220	5801 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97387	-118.41995	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21439	16041-10000-08374	1544 N LACHMAN LANE	90272	11	135B121    23	4420035008	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.0639	-118.54992	PV1. NEW RESIDENTIAL GROUND MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 19.2KWac.(80)MODULES-SUNMODULE SW 285(80)MICROINVERTERS-ENPHASE M250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21440	19041-10001-14450	1875 CENTURY PARK EAST 1900	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	PIN	34.06084104	-118.41471001	CHANGES TO APPROVED SET DELTA 1 ONLY. ADDING 2 NEW LIGHTS. <<HIGHRISE BUILDING OFFICE TI. PLAN CHECK FOR ENERGY: TOTAL EFFECTED AREA 2322 SQFT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21441	11041-20000-14799	127 S SAN VICENTE BLVD Bulletin-77TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	08/22/2011 12:00:00 AM		Permit Closed	02/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta # 77 TI. New branch cks added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21442	16041-10000-05518	14458 W VALLEY VISTA BLVD	91403	4	165A151   164	2276038016	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	PIN	34.14630547	-118.4491089	PV1, INSTALL 12.455 kW DC / 11.4kWac ROOF-MOUNTED  SOLAR ARRAY ON A SINGLE FAMILY HOME(47) MODULES: CANADIAN SOLAR CS6P-265P(1) INVERTER: SOLAREDGE SE 11400A-US 240V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21443	17041-20000-21189	11268 N TELFAIR AVE	91340	7	210B153   180	2616016020	R1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.27488	-118.43734	Plan check for solar pv system, roof-mounted on SFD.7.6kW ungrounded system. (26) 290W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21444	16041-20000-10124	6824 N BEN AVE	91605	2	183B165   578	2321023014	RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.04	Electrical	Electrical	Apartment			03/23/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.19474	-118.39418	(N) 5-unit, 2-story apartment building.  Plan check for energy for outdoor commercial lighting requirements.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21445	16041-10000-17643	2239 S VETERAN AVE	90064	5	126B153   659	4322011016	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Expired	06/21/2018 12:00:00 AM	ADDRESS	34.04114	-118.4336	INSTALLATION OF NEW SOLAR PV ARRAY ON DETATCHED GARAGE OF SINGLE FAMILY DWELLING.  NEW SYSTEM IS 4.2 KW.  TIE IN TO EXISTING 2 KW SYSTEM USING 125 A SOLAR ONLY LOAD CENTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21446	16041-20000-07953	8500 N BALBOA BLVD	91343	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Expired	04/06/2018 12:00:00 AM	PIN	34.22443327	-118.49947932	Renovation of (E) commercial engineering shop and storage space.  Plan check for energy.  4980 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21447	16041-20000-21778	14500 W OLIVE VIEW DR 1-100	91342	7	228B149    20	2502024024	QRD1.5-1, RD1.5-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	Apartment			06/21/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.32399	-118.44867	FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.Plan check for PV roof mounted system. System size: 33kW with 132 modules with 4 inverters(7.0 kW & 8.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21448	13041-20001-21025	12414 W DEERBROOK LANE	90049	11	138B141   381	4494009001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.07309	-118.48436	((8/6/2013 Expedite Fees))PV1 TRANSFORMERLESS SYSTEM. 4 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 7.848KW. 24 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21449	16041-30000-23396	5941 N ROD AVE	91367	3	177B085   479	2032021008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.17864	-118.66312	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21450	17041-10000-41113	6030 N LAUREL CANYON BLVD	91606	2	177B165   609	2333013019	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.1803	-118.39631	REPLACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21451	13041-20001-23729	7502 N JOLENE CT	91605	2	186B165   306	2307023***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			Reviewed by Supervisor	09/17/2013 12:00:00 AM	ADDRESS	34.20695	-118.40101	((EXPEDITE FEES))PV1 TRANSFOMERLESS SYSTEM. 25 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21452	19041-10000-36135	8532 N VINEVALLEY DR	91352	2	192B177    56	2404030010	RA-1, RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.22566	-118.35538	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 13.75KVA PV1 SYSTEM CONSISTING OF 35 MICRO INVERTERS(IQ7X-96-2-US) CONNECTED TO EXISTING 400A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21453	12041-20000-07139	8661 N SEPULVEDA BLVD	91343	7	195B145   524	2654020001	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.06	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.22796	-118.46792	NEW RETAIL STORE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21454	13041-10002-30114	7822 N QUARTZ AVE	91306	3	189B117   727	2106029016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.21279	-118.56395	Expedited RSES plan check per applicant request.(((PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 22 modules HANWHA # HSL60P6-PB-4-250TW.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21455	18041-10000-48968	6550 N LAUREL CANYON BLVD	91606	2	180B165   446	2322008029	C2-1L, P-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.18989	-118.39631	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21456	19041-10000-44789	749 S LOS ANGELES ST	90014	14	127-5A211 209	5145001900	PF-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	02/19/2020 12:00:00 AM		Issued	02/19/2020 12:00:00 AM	ADDRESS	34.04249	-118.25175	Permit fee is $0.00 due to AB1414PC for a ground mounted PV system. Scope including (1) 50KW inverter, and (190) modules  interconnecting to the 5000-amp main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21457	14041-20000-15814	12001 W CHALON ROAD A12	90049	11	141B141     5	4429003027	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.08469	-118.4849	Tittle 24 plan check only on an area of 750 SQ feet inside a campus building unit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21458	06041-10001-25939	3410 S LA CIENEGA BLVD	90016	10	120B173   310	5047018901	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Closed	09/30/2010 12:00:00 AM	ADDRESS	34.02602	-118.3719	Revisions to permitted set of plans for an air treatment facility for a sewer system.  That length (20' 0 of service conductors routed through the building to be encased in 2inch min. concrete;reduced length of some of the poles that outside luminaires are mounted; add 600A MCC  for 5hp pump/motors; revised load calculations	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21459	14041-20000-27287	16705 W BAHAMA ST	91343	12	195B137   214	2688043005	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.23334	-118.4968	PV1.  Install 3.67 kW roof-mounted, utility-interactive PV system.  AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21460	19041-20001-13116	5900 W CENTER DR 1-327	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	33.97559	-118.38853	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 136.88 kWdc/125.07 kWac-CEC and consists of (4) inverters, (375) modules, (1) transformer, and (2) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21461	16041-10000-16523	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.04538	-118.26389	New Fire alarm system for an existing Figueroa hotel. Installing (1) FA panel (7) Control panels (1) Communication panel, (1073) FA devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21462	17041-10000-31804	1475 S LONG BEACH AVE	90021	14	120A213    28	5130019036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.02476	-118.24191	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 7150 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21463	12041-10000-07622	1140 S ROBERTSON BLVD	90035	5	132B169   705	4332015018	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.05586	-118.38353	T.I. to a dental office.  Change to lighting, loads, and receptacles, and new panel.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21464	16041-20002-20723	7900 N BALBOA BLVD	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.21347	-118.50092	"Revisions to approved plans.  Additional HVAC equipment for Unit D1.  (((Plan check for power and energy for Van Nuys Airport Building ""D"" (Delta) aircraft hangar. Service size: 800A. Total area: 32,845 sq ftBuilding Applicant #: 16010-30000-01587)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21465	13041-20000-22955	3221 W TEMPLE ST	90026	13	139-5A201 237	5156007015	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village		1958.02	Electrical	Electrical	Apartment			08/22/2013 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.07565	-118.28154	pc for power and energy only. methane zone. CONSTRUCT 4 - STORY 67 UNITS APT. W/ 11 FOR VERY LOW INCOME AFFORDABLE HOUSING OVER PARKING GARAGE- Excercise room and office in the garage level;  21 units and 2 rec. rooms on 2nd flr.;  23 units on 3rd, 4th floors(((fire alarm variance has been filed 12-30-13))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21466	15041-10000-40939	2710 S SEVERANCE ST	90007	9	121-5A201  14	5123003411	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.02896	-118.28161	T-24, CHANGE OF USE FROM RESIDENTIAL TO CHILD DAY CARE. SCOPE OF WORK INCUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 10374 Note: PC only, Permit on supplemental, 15041-10001-40939	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21467	17041-10001-04263	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	01/12/2024 12:00:00 AM	ADDRESS	34.05048	-118.25755	PC FOR A LOST SET OF PLANS (T-24 FOR CNP NORTH LOBBY). CHANGE OF CONTRACTOR PERMIT FROM CUPERTINO ELECTRIC TO DSE ELECTRIC INC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21468	15041-10000-18077	523 W 6TH ST STE. 400	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21469	13041-10000-09278	2023 W GAGE AVE	90047	8	105B189  1279	6001020020	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	33.98196	-118.31437	construction of new bathrooms. only 2 fixtures 128 sq ft. per supervisor request, installed wattage < .6 w/sqft. energy compliance has been met. plan check approved per supervisor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21470	16041-10000-18406	20000 S WESTERN AVE	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.85008	-118.30908	ADDITION TO BUILDING. CONVERT WAREHOUSE SPACE TO OFFICES. NEW LIGHTING. NEW MEZZANINE. NEW LIGHTING PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21471	13041-10000-29988	1800 N NORTH MAIN ST	90031	14	135A219    12	5410015007	M3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			Ready to Issue	09/23/2014 12:00:00 AM	ADDRESS	34.06621	-118.22039	Upgrades to vehicle repair for CNG vehicles in a UPS Automotive Repair Facility.  Includes new gas detection system, power for exhaust fans, lighting revisions and new panels.  Potential hazardous classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21472	19041-20000-43770	1000 N NAPOLI DR	90272	11	129B133   371	4408008002	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	05/04/2020 12:00:00 AM		Permit Expired	09/29/2022 12:00:00 AM	ADDRESS	34.04574	-118.50585	Plan chek for new 600A Service supply load, new generator 59KW.Note. Most of  electrical permit fee is covered under building permit number 18014-30000-01244\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\per building application number 18014-30000-01244 work description: remobeling existing 2 story family dwelling\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21473	14041-10001-17286	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	ADDRESS	34.0484	-118.26248	((3/25/2015- CHANGES MADE TO APPROVED SET REVISED TITLE24 AND SOME CIRCUIT RELOCATION. THIS IS A PLAN CHECK ONLY APPLICATION))PC FOR POWER AND ENERGY. TOTAL AREA 20,265 SQ FT. OFFICE TI  CORE/SHELL. BUILDING APPLICATION# 14016-10000-12538	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21474	19041-10000-09318	13320 W PINNEY ST	91331	7	207B157   275	2619017025	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.26647	-118.42355	PC FOR T-24 FOR CHANGE OF USE FROM WAREHOUSE TO CHURCH. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFECTED AREA IS 7485 SQFT. F1 FIXTURE TO BE FIELD VERIFIED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21475	08041-10003-13153	1377 N SERRANO AVE # 104	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	04/07/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	REVISIONS TO LIGHTING IN ROOM 104  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21476	14041-10000-05706	1900 S AVENUE OF THE STARS 12th FLOOR	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.05979	-118.41671	REPLACE 9 FIXTURE IN THE ELEVATOR LOBBY. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21477	16041-10000-29503	7901 N SAN FERNANDO ROAD	91352	2	189B177   408	2466031901	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.21398	-118.36191	UPGRADE OF EXISTING SERVICE(240/120 AT 400A) TO NEW SERVICE(480/277 AT 600A) & PANELS AT EXISTING COMMERCIAL (AIRPORT AREA).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21478	16041-20000-30483	21830 W NORDHOFF ST	91311	3	198B105   190	2779020056	QMR1-1, QP-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.23521	-118.60422	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from a restaurant to a dental office. Total lighting area = 4,334 sq. ft. Note: Building permit has been pulled under 16014-20000-02868	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21479	17041-30000-31000	350 S GRAND AVE STE 3910	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only in existing high-rise building T.I. office building. Total area: 1475 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21480	18041-10000-34482	550 S HOPE ST #2200	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	Energy plan check for an office T.I located on the 22nd floor of a high rise building. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21481	15041-20001-38296	5437 N LUBAO AVE	91364	3	174B113   541	2164003017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.16938	-118.56707	EXPEDITE FEEPV1, 18.98 kW system, roof mounted solar array.  (73)modules: Canadian Solar CS6P-260P   (2)inverters: FRONIUS   PRIMO 8.2-1***Applicant REQUESTED this plan to be assigned in VN*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21482	19041-10000-53618	12706 W WALSH AVE	90066	11	108B157  1679	4223020036	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	33.98807	-118.42738	[EPLAN] NEW PV1 ROOF MOUNTED INSTALLATION WITH A SYSTEM SIZE OF  3.60KW DC/ 2.86KW AC, 10 MODULES (POWER XT-360R), 1 CENTRAL INVERTER (SE3800H-US), 1 ESS (TESLA POWERWALL), 2 SUBPANELS RATED FOR 125A, 200A, AND NEW MAIN SERVICE PANEL RATED FOR 225A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21483	12041-20000-00200	8024 W MELROSE AVE	90048	5	141B177   618	5527015037	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	PIN	34.08349782	-118.36462438	Plan check for energy only.  Permit is for relocation of existing panel and installing new circuits to sale area counter and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21484	14041-20000-32250	6909 S LA TIJERA BLVD	90045	11	102B173   146	4103003016	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM			PC Info Complete	06/11/2015 12:00:00 AM	ADDRESS	33.97611	-118.37341	PLANCHECK FOR POWER ONLY. SERVICE AND MSB UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21485	15041-10000-06594	888 S OLIVE ST	90014	14	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			03/06/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	Revisions to to permitted set of plans: added feeder for retail space; changed main for residential switch board to 4500A;added 18 presedential apt units; added 9 feeders to replace 3000A busduct to supply residential distribution boards; show separtion of sections for the generator distribution board and show fire pump emergency sections separate from the other sections No lighting applied to this permit.NOTE TO PLAN CHECK: PROJECT MANAGER, MATTHEW GLEESON, TOOK PLANS BACK TO UPDATE ADDITIONAL CHANGES ON 11/13/2013; IF THOSE ADDITIONAL CHANGES EXCEED THE ORIGINAL SUBMITAL FEES THE PLANS WILL BE SUBJECTED TO ADDITIONAL FEES TO REFLECT THE OVERALL CHANGES.  ((((((((((NEW 33 STORIES HIGH-RISE MIXED USE BUILDING ( COMMERCIAL AND 283 UNITS ) OVER PRIVATE PARKING GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21486	19041-20000-48272	9924 N POOLE AVE	91040	7	201B177    49	2542013046	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	08/03/2020 12:00:00 AM	ADDRESS	34.25069	-118.36166	PV1.  Install 4.96 kW ground mounted PV system.  (16) modules with 5 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21487	14041-10000-03278	1100 S SAN PEDRO ST G06	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.03515	-118.25194	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 450 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21488	16041-10001-28136	307 N LA BREA AVE	90036	5	138B181   364	5525033032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.07647	-118.34435	Plan check for Power only.  Renovation of existing car wash.  Scope includes adding motor and circuits for carwash.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21489	19041-10000-23593	9220 S SEPULVEDA BLVD	90045	11	093B165    76	4124001008	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	33.9529	-118.39595	Energy plan check for removing HID fixtures and replace with new LED fixtures in a commeical building with a total lighting area of 8375-SQ FT. (outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21490	18041-10002-22138	7422 W 80TH ST	90045	11	099B157   286	4114014017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	33.96364	-118.42711	SUPPLEMENTAL FOR CHANGES TO APPROVED SET - RELOCATIION OF PV MODULES ONLY, SEE ROOF PLAN NOTE: PERMIT FEES ARE REDUCED DUE TO SENATE BILL 1222.INSTALL A 11.375 (DC) KW, 10.46 (AC) KW, WITH 35 SOLAR MODULES ON A SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21491	17041-10000-01273	11258 W NEBRASKA AVE 1-5	90025	11	126B153   247	4261020004	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM			Corrections Issued	02/02/2017 12:00:00 AM	ADDRESS	34.04413	-118.44561	PV,  INSTALLATION OF 5.04 KW DC /5.2 KW AC ROOF-MOUNTED SOLAR SYSTEM ON COMMERCIAL BUILDING. (16) MODULES: LG LG315NIC-Z4(1) INVERTER: DELTA SOILVIA  5.2 TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21492	16041-20000-40996	10249 ANGEL LANE	91331	7	204B165   434	2537004044	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25674878	-118.40460911	pv1install roof mounted pv system sized 3.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21493	16041-10000-39886	4601 N FIRMAMENT AVE	91436	5	168B141   713	2283001025	C4-1L, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.15395	-118.47231	PC for energy only. Remove HID fixtures and replace with new LED fixtures. Total sqft = 5850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21494	19041-10000-01875	3737 W OLYMPIC BLVD	90019	4	129B189    84	5092017035	[T][Q]C2-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.05342	-118.31911	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21495	19041-10000-53667	13025 W VALLEYHEART DR	91604	2	165B161   757	2375019048	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Issued	01/16/2020 12:00:00 AM	ADDRESS	34.14729	-118.41694	[EPLAN] Installing 2 ESS (Tesla Powerwall) with existing PV system, 2 subpanels rated for 200A and new 200A main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21496	15041-10000-42671	9716 N GLADBECK AVE	91324	12	201B121   416	2763033024	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.2469	-118.53948	PV1, INSTALL 7.50 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(30) MODULES: PHONOSOLAR PS 250P(30) MOICRO INVERTER: ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21497	11041-10000-11452	5460 W SANTA MONICA BLVD	90029	13	144B193   752	5536023010	C2-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.09063	-118.30816	TI TO AN EXISTING MIXED USE, COMERCIAL/RESIDENTIAL 2-STORY BUILDING.  RELOCATING PANELS TO ELECTRICAL ROOM WITH NEW SERVICE.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21498	18041-10000-36371	523 W 6TH ST 1ST FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	Energy plan check for MEN'S AND WOMEN'S 1ST FLOOR RESTROOMS TI. Scope includes new lighting and equipment with a total area of 435-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21499	19041-10000-43215	7008 W WOODROW WILSON DR	90068	4	157-5A181 369	2429020012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.12488	-118.34673	Plan check for a new 10kW AC/ 12.78KW DC PV1 roofmounted system. Scope includes (1) inverter, (35) modules and optimizers inter connecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21500	14041-20000-21039	5264 N TOWNSEND AVE	90041	14	163-5A227 108	5669014026	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.14331	-118.20108	New roof mounted PV system with Enphase model M250-60-2LL.  Total system size 6.72KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21501	16041-10000-43185	4147 S SUNNYSIDE AVE	90066	11	108B153  1049	4230011017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Issued	01/10/2017 12:00:00 AM	ADDRESS	33.99028	-118.43885	$0 fee due to senate bill 1222 from 2012PC FOR PV SYSTEM ROOF MOUNTED, TOTAL SYSTEM SIZE 13KW AC USING 2 CENTRAL INVERTERS AND TOTAL OF 49 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21502	16041-20001-40858	12644 W HESBY ST	91607	2	171B161   923	2357008014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.16205	-118.40871	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 400A split bus MSP. 12kW (6+6) ungrounded system. (50) 300W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21503	09041-20003-20084	9311 N SEPULVEDA BLVD 1-4	91343	7	198B145   189	2656018027	R3-1	North Valley	Mission Hills - Panorama City - North Hills			1172.01	Electrical	Electrical	Apartment			06/15/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	34.23957	-118.46796	change DBA DBB from 225 a 200 c/b to 250 A 250 A c/b	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21504	13041-20000-15008	7238 N SEPULVEDA BLVD	91405	6	186B145   843	2221018016	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.20243	-118.466	T24 FOR BEAUTY SALON. TOTAL SQRFT 640.5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21505	15041-10000-05835	3012 S BAGLEY AVE	90034	5	123B165   485	4311022003	R1-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Expired	05/05/2017 12:00:00 AM	ADDRESS	34.03427	-118.39456	PV1.  Install 4.59 kW roof-mounted PV system.  (E) 4.62 kW roof-mounted system interconnected with new system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21506	15041-20000-18516	19155 W VICTORY BLVD Bldg 4	91335	3	180B121   526	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.18675	-118.55116	Plan check for a PV2 roof-mounted PV system. System size is 4 kWac and consists of (1) inverter, and (20) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21507	13041-20000-14780	13265 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW. USING 15 MODULES ENPHASE M215 MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21508	13041-10000-23362	446-450 S MAIN ST	90013	14	129A211   140	5148009012	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.0471	-118.24791	More than 50% design change. New set of plans submitted. Full plan check power and energy for renovation of theater. New service size 800A. Total new load 740A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21509	14041-10002-30573	1837 S SAWTELLE BLVD	90025	11	126B149   405	4261021008	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			07/03/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.04291	-118.44567	change to approved set by adding (1) new ckt and modifying some lighting fixture.All changes under delta-2 only.(((New 5-story apartment, 19 units, with grade-level parking.  Plan check for power and energy.BLDG#14010-10000-03535. See additional comments.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21510	14041-20001-03100	4900 N RADFORD AVE	91607	2	168B169   181	2355013008	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.15972	-118.39194	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE8.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21511	18041-10000-21976	2049 S CENTURY PARK EAST Suite#1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN AN EXISTING OFFICE AREA IN SUITE #1940 ON THE 19TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21512	13041-20000-17905	3330 N CAHUENGA BLVD WEST SUITE 302	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.13099	-118.35061	TI FOR EXISTING NON HIGHRISE OFFICE SPACE. THIS PLAN CHECK IS FOR SUITE 302. TOTAL SQRFT: 326	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21513	15041-20000-22252	5000 W SUNSET BLVD Suite 600	90027	13	147B197   756	5543024022	C2-1D	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.09788	-118.29844	Title 24 plan check only.  Total area = 1,796 sq. ft.  T.I. to existing low rise commercial office space.  Plan check for alternate lighting scheme.  Plan check only - permit to be pulled under application #15041-20000-22251	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21514	13041-10000-10827	4206 W HOLLY KNOLL DR	90027	4	150B201   716	5591017017	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2013 12:00:00 AM			PC Approved	04/26/2013 12:00:00 AM	ADDRESS	34.10697	-118.28134	PV1 for single story house.  Plan check only for express permit previously pulled under 13041-10000-04621 per inspector request.  5.76 kw dc system size.  {Transformerless inverter: PowerOne PVI-6000-OUTD-US} {24 modules: Panasonic VBHN240SA06}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21515	10041-10000-09968	11480 W TIARA ST	91601	4	177B169   978	2338012900	PF-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	34.17839	-118.38171	NEW ONE STORY MULTIPURPOSE BUILDING WITH A MULTIPURPOSE ROOM, AN OFFICE AND ANCILLARY SPACES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21516	14041-20003-00054	18725 W SHERMAN WAY	91335	3	183B121    99	2118026018	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.20128	-118.54148	[[[[[1/28/15  CHANGES TO APPROVED SET. DELTA 2 CHANGES ONLY. CHANGES TO LIGHTING, INCLUSION OF OUTDOOR LIGHTING. LOADS ADDED TO PANEL LA ]]]]]Modifications to approved set.  Changes to single line diagram layout.  Additional HVAC loads.  (((Change from retail to adult daycare.  Install new panel, branch circuits, and lighting.  Plan check for power and energy.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21517	18041-20000-21870	1999 S AVENUE OF THE STARS 37th Floor-Balcony	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 Energy only in existing high rise building balcony T.I. 37th Floor Total area: 382 sq ft. B#18016-10000-17866	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21518	16041-20000-44265	6550 ELMHURST DR	91042	7	198B201   268	2572047027	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	PIN	34.23952628	-118.27451869	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP.7.68kW ungrounded system. (32) EnPhase M250 microinverters. (32) 275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21519	15041-20001-42773	10310-10440 N SEPULVEDA BLVD Bldg 4	91345	7	204B145   259	2649019007	C2-1, CR-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM			PC Approved	11/14/2016 12:00:00 AM	ADDRESS	34.25776	-118.46707	11.14.2016 - Plan check for power only. New 1200A switchboard. New panels (4H, 4D, 4EV, and 4DPE). New house loads. ======T-24, ADDITION TO COMMERCIAL BUILDING AND MAINTENANCE ROOMS AND REMODEL OF EXTERIOR FACADE. SCOPE OF WORK INCLUDES NEW LIGHITNG. TOTAL SQ. FT. 3680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21520	16041-20000-45007	13078 E MINDANAO WAY 116	90292	11	105B153    45	4212009***	(Q)RD2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	33.98673	-118.43554	Upgrade to lighting system in (E) elevator lobby in lowrise condominium building.  Plan check for energy.  Permit has already been obtained under 16041-90000-43734.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21521	11041-20000-21478	400 S HOPE ST 4th floor	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Info Complete	10/07/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	energy plan check 4th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21522	14041-20000-35311	6934 N ALABAMA AVE	91303	3	183B105   750	2138012010	R2-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM			Corrections Issued	01/06/2015 12:00:00 AM	ADDRESS	34.19659	-118.59887	PV1. Install roof mounted PV system sized 6 KW to sfd. Interconnected with main service pannel. (18) Sunpower SPR-327 NE Modules(1) SMA SB6000TL-US-12 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21523	14041-20001-04487	714 N GENESEE AVE	90046	5	141B177   496	5527008009	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.08432	-118.35829	Expedite Fee ONLY*****New roof mounted PV system with 4.08KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21524	16041-10000-41258	24116 W CLARINGTON DR	91304	12	186B089   230	2027039017	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.20816	-118.65185	PC for new 10.2KW rooftop solar PV with 32 AC modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21525	16041-10000-09434	5830 E YORK BLVD	90042	14	154-5A229 162	5484015012	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.20	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.11822	-118.19126	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM A SINGLE FAMILY DWELLING TO A RESTUARANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1632 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21526	17041-20000-03309	4101 S REDWOOD AVE	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.99086	-118.44043	"Plan check for power only. New distribution panel ""C"" and feeder only for existing commercial building (3). Change of use from manufacturing to office. Building permit application #16014-20000-04306."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21527	17041-20000-23483	2345 S GAFFEY ST	90731	15	009B197   372	7463005027	RD1.5-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2972.01	Electrical	Electrical	Apartment			07/12/2017 12:00:00 AM			Reviewed by Supervisor	08/15/2017 12:00:00 AM	ADDRESS	33.72271	-118.2926	New 4 story 8 unit apartment building with 1 level of parking garage.  800A 120/240V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21528	14041-20000-19227	17217 W OTSEGO ST	91316	5	171B133   401	2258008009	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.16387	-118.50831	PV1Microinverter standard plan.Install a roof-mounted solar array on SFD. System size: 4.8kW.(20) EnPhase M250 microinverters(20) SolarWorld SW280 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21529	18041-20000-11657	4050-4060 S FIGUEROA ST	90037	9	115-5A201 220	5019026009	C2-1L	South Los Angeles	Southeast Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	07/28/2021 12:00:00 AM	ADDRESS	34.01002	-118.2825	Plan check for power and energy. Project site is a new 5-story mixed-use building: 1 level of commercial with 4 levels of residential over 1 level of subterranean parking garage. Work includes a 2,000-amp service and a total lighting area of 33,358 sq. ft.Note: Building application has been generated under 18010-10000-00366	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21530	13041-20000-26796	11308 N SINCLAIR PL	91326	12	213B121   862	2871020010	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.27631	-118.5395	PV1 MICROINVERTER PLAN. TOTAL SYSTEM SIZE 7.3KWAC. 34 PANELS AND MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21531	16041-10000-00550	1256 W 7TH ST roof	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.05216	-118.26774	NEW LUMINAIRES AND POWER TO NEW ROOF POOL AND BAR AND ASSOCIATED  AREASPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21532	11041-20000-20251	12050 W VENTURA BLVD B201	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	09/22/2011 12:00:00 AM	ADDRESS	34.14349	-118.39426	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING INTERIOR T.I. TO RETAIL SPACE TO ADD PARTITION WALL. LIGHTING EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21533	15041-20001-26638	221 N FIGUEROA ST 8th Floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	09/02/2015 Changes to an approved set of plans. Changes include fixture type changes and recalculation of emergency lighting photometrics. All changs have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is the 8th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 17,767 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21534	19041-20000-49349	10880 W WILSHIRE BLVD Floors 8-10	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	09/13/2020 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check for title 24 Energy for new lighting. Total area: 1861 sq ft. B#19016-40000-34409	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21535	15041-20001-42776	10410 N SEPULVEDA BLVD	91345	7	204B145    69	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.25968	-118.46706	Revisions to approved set.  Value engineering to aluminum conductors and changes to gear orientation.  Approval for clouded changes delta-J only.  (((Full Plan check for an existing  building being remodeled.  Service upgrade to 1200. Panel LA and LB loads to be featured. Total sqft = 7258.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21536	12041-10000-18986	2040 N BARNETT WAY	90032	14	136-5A235 338	5223024008	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.06691	-118.17317	Plan check for new roof mounted 5.886KW photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21537	16041-10000-07239	3864 S CRENSHAW BLVD	90008	10	117B185   821	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.01572	-118.33474	PC for energy only to a a restuarant. Adding new light fixtures and power to customer area. Total Sqft = 1833.2008 Title 24, building appllication number : 13016-10000-25279.*** PC ONLY, Inspection fees were paid under express permit # 14041-70000-17809.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21538	17041-20000-42270	4370 N WINNETKA AVE	91364	3	165B113   108	2174026030	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.1502	-118.57155	ti to an existing commercial building.  adding new lighting and new controls to existing panels.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21539	11041-10000-12832	1399 S ROXBURY DR	90035	5	132A165   329	4330005046	C4-1VL-O	West Los Angeles	West Los Angeles			2690.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.05409	-118.40253	TI TO AN EXISTING WALGREENS.  PLAN CHECK ONLY IS FOR ENERGY WITH EMERGENCY LIGHTING ONLY.  OTC - PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21540	11041-20000-04143	9089 N CANTERBURY AVE	91331	6	198B157  1031	2640003001	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.23523	-118.43068	Car port roof mounted PV system with microinverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21541	15041-20000-01212	10342 N LINDLEY AVE	91325	12	204B125   120	2731010016	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	PIN	34.25819985	-118.52695571	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20.0KW INTERCONNECTED WITH MSP.THIS IS 1  PV DESIGN OF TWO.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21542	16041-10000-02880	6801 W HOLLYWOOD BLVD #253	90028	13	148-5A185 402	5548004041	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	TENANT IMPROVEMENT TO (E) TAKE OUT RESTAURANT. PC FOR ENERGY ONLY. TOTAL AREA 490 SQ.FT. (INDOOR+OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21543	13041-20000-35284	18131 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.16596	-118.52824	Application to follow application # 13041-20000-31716. This is plan check in association with original application for Generator and emergency panel located in parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21544	16041-10000-29518	1825 N LAS PALMAS AVE 1-118	90028	13	150A185   301	5547001022	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			09/30/2016 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	01/28/2022 12:00:00 AM	ADDRESS	34.10476	-118.33652	FULL PLAN CHECK FOR NEW MIX-USE BUILDING, 6 STORY, BOTH COMMERCIAL AND 118 UNIT APPARTMENT WITH 17 TYP UNITS. TITLE 24 AREA = 147007SQ. FT.((B# 16010-10001-01430))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21545	15041-10000-18383	3100 W SAN FERNANDO ROAD	90065	13	153A213    46	5458002015	[Q]C2-1VL-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM			PC Approved	06/12/2015 12:00:00 AM	ADDRESS	34.1149	-118.24619	PC FOR T24. T.I. FOR ADDING 482 SQ FT AREA TO A CONVENIANCE STORE IN A GAS STATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21546	19041-20000-03472	22729 W GAULT ST	91307	12	183B097   226	2024019011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.19925	-118.62178	PV1.  Install 7.59 kW DC / 7.6 kW AC roof mounted grid tied PV system.  (23) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21547	19041-10000-43529	5825 W SANTA MONICA BLVD Bldg A	90038	13	144B189   595	5534017022	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	07/27/2022 12:00:00 AM	ADDRESS	34.09089	-118.31662	"0$ final fees per AB1414Bldg ""A"" - ROOF TOP SOLAR PLAN CHECK FOR 40KWac (46.129 KW CEC AC) (51.48 KWdc) USING 156 AXITEC-AC-330P/156-72S MODULES, 78 SOLAREDGE P730 OPTIMIZERS, AND 2 SOLAREDGE SE20KUS INVERTERS."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21548	15041-20001-24864	13921 W CHANDLER BLVD	91401	4	171B153   927	2247012032	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2015 12:00:00 AM			PC Approved	08/12/2015 12:00:00 AM	ADDRESS	34.16871	-118.4364	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.3 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21549	16041-10000-17715	1717 S WESTERN AVE	90006	10	126B193  1421	5073012034	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.04214	-118.30925	TI to an (E) Food for Less #381. Install new lightings and receptacles, new connected load < 400A. PC for Energy only.  Total area 35,351 sq. ft.B# 16016-10000-11559	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21550	12041-10000-10291	5867 W 3RD ST	90036	5	135B181   118	5512022024	[Q]C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM			PC Approved	05/10/2012 12:00:00 AM	ADDRESS	34.06948	-118.34813	Change of use from Laundromat to Retail.  Occupancy load is less than 99, and load is 200A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21551	17041-10000-14102	458 S ALAMEDA ST	90013	14	127-5A215 415	5163026008	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.04162	-118.23803	Plan check for energy only, Indoor Title-24. Removing HID fixtures and replacing them with new led ones.Area: 6,400 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21552	17041-20000-42996	10807 W BELLAGIO ROAD	90077	5	138B149    26	4362006006	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Issued	12/21/2017 12:00:00 AM	ADDRESS	34.07832	-118.45299	pv1install roof mounted pv system with battery back up interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21553	14041-10000-11754	11261 W SANTA MONICA BLVD	90025	11	129B149   361	4261007030	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.04687	-118.4478	NEW SERVICE FOR HYDROGEN FUELING EQUIPMENT. HAZARDOUS LOCATION. BUILDING PERMIT#: 13020-10000-01342	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21554	11041-10000-03861	8000 W MELROSE AVE	90048	5	141B177   613	5527015001	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM			PC Approved	04/20/2011 12:00:00 AM	PIN	34.08351456	-118.36392945	T.I.  TO EXISTING RETAIL STORE.  TITLE 24 ONLY.  SINGLE STORY BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21555	19041-10000-06782	3150 W SAN FERNANDO ROAD	90065	13	153B209   514	5458002013	[Q]C2-1VL-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.11582	-118.24713	T-24, PC FOR ENERGY ONLY. INTERIOR  T.I  TO (E) OFFICE SUITE (2488 S.F)  AT  (E) GOODWILL FACILITY. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS  2367 SQ. FT. B#18016-10000-35365	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21556	19041-10000-07662	16501 W VENTURA BLVD #500	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.1578	-118.49275	TITLE 24 PLAN CHECK ONLY FOR - TENANT IMPROVMENT TO THE (E) OFFICE SPACE ON 5TH FLOOR. REMOVE AND REPLACE PARTITION WALLS, SUSPENDED CEILING AND NEW FINISHES. - TOTAL AFFECTED AREA = 6404 SF. NEW LIGHTS AND OUTLETS ON EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21557	17041-20000-23794	18165 W ECCLES ST	91325	12	192B125   355	2786025022	RS-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.2239	-118.52975	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21558	15041-20000-01325	3667 S MCCLINTOCK AVE	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.02081	-118.29008	PULL AND EXTEND MV CABLE TO SUPPLY FUTURE BUILDING. NEW BUILDING OFF PB 32. WILL RECIEVED 2 NEW FEEDERS FROM 2 DIFFERENT SERVICES. TOTAL LEGTH OF MV CABLE APROXX 1800 LN FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21559	16041-10000-11002	11769 N GLENCREST DR	91340	7	213B157    59	2524002016	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Expired	05/02/2018 12:00:00 AM	ADDRESS	34.28407	-118.42138	PV1 solar system installation to a single family dwelling. Connecting 35 solar micro inverter modules, size of system: 8.75 kw. 125 A load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21560	17041-20000-09759	333 S HOPE ST ste 1000	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only and em lighitng.  total square footage 8617 in suite 1000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21561	11041-10000-15149	2644 N EDEN PL	90210	5	156B165   263	4388002043	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.11986	-118.40045	New 4.56 KW roof mounted PV system on a single family residence.  Regular plan cehck.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21562	17041-10000-46409	10870 W VICENZA WAY	90077	5	147B145   173	4369039025	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2017 12:00:00 AM	01/28/2021 12:00:00 AM		Issued	01/28/2021 12:00:00 AM	ADDRESS	34.09718	-118.45899	PC for power for 2 story SFD. Installing 600A 120/240V service with 12 panels, new equipment and branch circuits. B# 15010-40000-04498. Portion of permit fee for electrical is included in combo permit under builing application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21563	13041-10002-14023	380 WORLD WAY Space T51B	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to approved set of plans delta-5 field coordination revisions: as-built to show field-installed loads missing from approved set as well as updated breaker ratings on tenant panel.  (((ASBUILT to show that 208V panel + transformer moved from 277/480V to 208 distribution board (now without transformer). Original Description: pc for power and energy. retail STORE FRONT ONLY (Starbucks).  1st time TENANT IMPROVEMENT in LAX (Space T51B).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21564	10041-10001-14381	14800 W CORONA DEL MAR	90272	11	123B129   762	4411028010	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02, 2628.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Finaled	09/22/2010 12:00:00 AM	ADDRESS	34.03068	-118.51908	Changes to approved plans. Plan Check is for additional loads.T.I. to existing building.  New service, panels, and branch circuits.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21565	13041-20000-33303	5260 N BELLINGHAM AVE	91607	2	171B165   327	2347020015	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			11/27/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.1663	-118.39912	ADDING LAUDRY CIRCUIT [ELECTRIC DRYER] TO EXISTING 25 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21566	16041-10000-34341	1700-1704 W SUNSET BLVD	90026	13	139-5A209 152	5404017020	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	01/31/2024 12:00:00 AM	ADDRESS	34.0771	-118.25863	CHANGE OF USE TO RESTAURANT WITH BREWERY. PLAN CHECK PER APPLICANT REQUEST. PROVIDING NEW SERVICE SECTION 400A TAP OFF EXISTING SERVICE. NEW LIGHTING AND EQUIPMENT. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21567	19041-20000-41180	11147 N WOODLEY AVE	91344	12	210B141  1091	2681011043	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM	01/06/2023 12:00:00 AM		Issued	01/06/2023 12:00:00 AM	ADDRESS	34.27316	-118.48497	PLAN CHECK FOR A 4000A SERVICE, (3) PANEL OVER 1200A, (18) PANELS 601-1200A, (1) PANEL 201-600A, (83) PANELS 0-200A, (160) EQUIPMENT 3.1-5 KVA, (15) EQUIPMENT 5.1-20 KVA, (832) BRANCH CIRCUITS, AND T24 TOTAL SQUARE FOOTAGE = 96979 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21568	17041-20000-03545	2010 S CHARITON ST	90034	10	126B173   802	4302034023	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Apartment			02/02/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Issued	04/28/2017 12:00:00 AM	ADDRESS	34.04017	-118.37798	service upgrade 600 amps to an existing apartment building.  plan check for power only, reconnecting existing feeders.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21569	15041-10000-22269	4239 W VIRGINIA AVE	90029	13	145-5A201 292	5429003024	R1-1	Central	Hollywood	Los Feliz		1913.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.09273	-118.28401	PV1. INSTALL 4.505 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(17) MODULES: KYOCERA KU2606CPA(1) INVERTERS: ABB PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21570	17041-20000-22045	2543 N HUTTON DR	90210	5	153B153    22	4382009005	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.11816	-118.43429	PLANCHECK ONL.Y New two-story accessory living quarters with attached garage.  New 1000 A 120/240V 1ph-3w service.Building permit under 17010-20000-00224	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21571	13041-20000-30932	735 S FIGUEROA ST LEVEL M3	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	01/24/2014 12:00:00 AM		Issued	01/24/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	PC FOR POWER AND ENERGY. NEW H&M RETAIL. WORK DONE IN LEVEL M3. #303. NEW EQUIPMENT RATED >600A. ENERGY USING TAILORED METHOD..  PLANS AND PERMIT ARE TO BE SUBJECT TO 2013 CALIFORNIA ELECTRICAL CODE, PER VARIANCE SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21572	16041-20001-08863	410 S HOBART BLVD 1-67	90020	10	135B193   473	5503011022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.06674	-118.30517	RSES expedited plan check fee per applicant request.  PV2.  Installation of 49.6 kW DC roof-mounted PV system.  (2) 9000W and (2) 11000W inverters with (160) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21573	15041-10000-43537	12725 W BLUFF CREEK DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	33.97499	-118.4153	Full plan check for a new building under a single plan, located in the same job site of a Methane ZONE, consists of  (6) new stand alone buildings with (6) different addresses and application numbers; Each building is identical and has 4-story and 6 units supplied by a 600-Amp service;  All electrical work for the plan are identical to  reference building applicaton #15041-10000-27550 located at the same site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21574	14041-10000-02441	1810 S PANDORA AVE	90025	5	132B157   764	4317001005	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Info Complete	02/12/2014 12:00:00 AM	ADDRESS	34.05644	-118.42429	INSTALLATION OF ELECTRONIC GAS DETECTION AND ALARM SYSTEM AS PART OF METHANE MITIGATION- LEVEL 5 - FOR NEW APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21575	17041-10000-02248	1200 W ANAHEIM ST	90744	15	030B201   242	7416008026	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Refund in Progress	08/22/2017 12:00:00 AM	ADDRESS	33.77901	-118.27695	PC for outdoor tile 24 only. Remove HID fixtures and replace with new LED fixtures. Area: 10,800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21576	18041-20000-22646	8564 W HILLSIDE AVE	90069	4	148-5A173 443	5558028015	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.09985	-118.37311	Plan check for PV roof mounted system, System size: 3.0kWac with 16 modules and 1 inverter(3.0.kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21577	17041-20000-45866	13548 W VENTURA BLVD	91423	4	165B157   746	2373011004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.14744	-118.42876	Change of use from beer tavern to pre-school.  Tenant improvement - plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21578	15041-10004-14888	1100 S HILL ST	90015	14	126A209   128	5139019034	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			12/05/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.03989	-118.25984	Changes to approved set of plans - changes are noted under delta 22A for single line diagram, and delta 24 for layout - changes for delta 22A include updating part of distribution equipment to field installation (3000A to 2000A) load calculations stay the same. Changes for delta 24 include updating title 24 calculations and reduction of lights in common area.  Original permit #15041-10000-14888	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21579	17041-20000-21005	19816 W MARIPOSA PINES WAY	91326	12	216B113    59	2701035017	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.28491	-118.5675	Plan check for solar pv system, roof-mounted on SFD.6.6kW ungrounded system. (24) 325W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21580	17041-10000-35975	18546 W SHERMAN WAY	91335	3	183B125   162	2126006005	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Issued	10/06/2017 12:00:00 AM	ADDRESS	34.20098	-118.53768	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21581	17041-10000-12858	505 S VIRGIL AVE #306	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.0649	-118.28724	MEDICAL OFFICE TI. NEW WIRING AND LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21582	14041-10000-01979	10473 W SANTA MONICA BLVD	90024	5	132B157   795	4326032016	(T)(Q)RAS4-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Public Safety Only			01/23/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	PIN	34.05625367	-118.42658724	NEW FIRE ALARM SYSTEM FOR 24-UNITS 5-STORIES APT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21583	18041-10000-05239	15305 W RAYEN ST 2ND FLOOR	91343	7	195B145   216	2654005021	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.232	-118.46592	INTERIOR TENANT IMPROVEMENT IN PART OF EXISTING OFFICE SPACE  ON THE 2ND FLOORPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21584	17041-20000-42765	11853 N EDDLESTON DR	91326	12	216B125   161	2870023038	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.28875	-118.53492	Plan check for solar pv system, roof-mounted array on SFD.8.4kW ungrounded system. (30) EnPhase IQ6PLUS-72.(30) 360W pv modules. Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21585	15041-10000-37150	1432 N CURSON AVE	90046	4	147B177  1112	5550026006	R3-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Apartment			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.09714	-118.35488	New fire alarm system for apartment including 50 fa devices, 1 control panel, 1 communication panel and 1 fa panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21586	18041-20000-14223	8554 N NEVADA AVE	91304	12	192B101   107	2010015001	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Issued	04/24/2018 12:00:00 AM	ADDRESS	34.22558	-118.60887	PV1.  Install 15.2 kW AC roof mounted grid tied PV system.  (47) modules with (2) 7.6 kW AC rated string inverters.$32.05 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21587	18041-20000-42531	10921 W CHANDLER BLVD	91601	2	171B173    74	2416002006	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM			PC Info Complete	11/06/2018 12:00:00 AM	ADDRESS	34.16876	-118.3688	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,840 sq. ft.Note: Building permit has been issued under 18016-20000-42531	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21588	15041-10000-12488	1801 S FIGUEROA ST	90015	9	124-5A205 282	5126002015	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.03524	-118.27179	Energy plan check for outdoor lighting at the ground parking lot with total area is 35700-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21589	15041-20000-41720	2860 W SUNSET BLVD FLOYDS 99	90026	13	141A205    16	5426020010	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	02/16/2016 12:00:00 AM		Issued	02/16/2016 12:00:00 AM	ADDRESS	34.08268	-118.27338	TI to an  (E) 2 commercial building to be one commercial build (Floyds 99 Barbershop). PC for Energy only. Total area: 1,500 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21590	14041-20000-30445	1242 E ADAMS BLVD	90011	9	118-5A211 446	5119021008	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Apartment			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.01694	-118.25129	pv1 sfd. total system size 4.3KW AC USING MICROINVERTER SYSTEM. USING 20 MODULES TOTAL. ENPHASE M215. NONSTANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21591	17041-20000-18218	10100 W VENICE BLVD	90232	5	120B165  1282	4208002019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.0221	-118.40033	"Plan check for power and energy 4 existing story T.I. reuse existing service and panel boards. load exceed 400A Total area: 36,625 sq ft. B""COMPLY WITH DEPARTMENT ORDER effective date12/15/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""B#17016-10000-13819"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21592	16041-10000-11940	1206 W 79TH ST	90044	8	099B197   572	6033007022	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	33.96715	-118.29654	PV1 solar system roof mounted installation to a single family home. Inverter size: 3.8 kw, 13 modules in series.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21593	16041-20000-05744	9335 N GEYSER AVE	91324	12	198B121   348	2763020005	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.24019	-118.54259	Plan check for PV roof mounted system. System size: 8.0kW with 38 modules and 1 inverter(3.0 and 5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21594	14041-20000-18040	10613 N MONTGOMERY AVE	91344	12	207B141   523	2668008008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.26327	-118.48175	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.2KW INTERCONNECTED WITH MSP.(18) TRINA SOLAR TSM-255(1) POWER ONE TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21595	15041-10000-06820	2910 N ALLESANDRO ST	90039	13	150B213   870	5442024045	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.10414	-118.24606	REPLACE HID LUMINAIRES IN THE BAY OF AN AUTO REPAIR SHOP WITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21596	17041-30000-26128	600 S DETROIT ST	90036	4	135B181   600	5508007027	[Q]R4-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Apartment			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.06469	-118.34496	Plan check for replace existing panel to new addressable fie alarm control panel with existing fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21597	18041-20000-05175	5318 S VERMONT AVE	90037	9	108B197   545	5001005033	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	33.99358	-118.29133	ti to existing outdoor parking lights.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21598	18041-20000-33040	9913 N SHIRLEY AVE	91324	12	201B117    69	2726013007	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.25045	-118.55922	Plan check for PV roof mounted system, system size: 8.9kW AC, 10.2kW DC STC with 34 modules and 34 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21599	18041-20002-13383	6130 N LAUREL CANYON BLVD	91606	2	177B165  1100	2334011029	(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM	ADDRESS	34.18148	-118.39573	08-09-2019 Changes to an permitted set of plan Builidng C, D, E, F, and P. Changes include revise grounding details between transformers to building distribution, loop distribtion overcurrent protection rating to address coordination. Changes apply to delta 5. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21600	17041-10000-02377	433 S SPRING ST	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	PC FOR POWER AND ENERGY. EXTENDING  OFFICE  ON THE LEVEL 2 MEZZANINE, AND T.I FOR  OFFICE AND RETAIL IN A 13 STORY BUILDING.  SHELL ONLY.  NEW SERVICE 5000A 480/277 V. TOTAL AREA  38408 SQ FT.B# 16014-10000-04123	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21601	19041-10000-42999	15149 W SYLVAN ST	91411	6	177B145    85	2242015007	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.18497	-118.46351	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 10.24KWac USING 32 SUN POWER E19 MODULES AND ENPHASE IQ7X MICROINVERTERS. CONNECTED TO A 200 AMP EXISTING SERVICE. MAIN BREAKER DERATE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21602	17041-10000-15590	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Closed	10/10/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	Plan check for Temporary power for a new 16-floor Highrise Office Building with Ground Floor Retail. Installing two services for temporary power. Scope includes installing one 800A  480/277 3 phase 4 wire service/distribution board and one 1000A 480/277 3 phase 4 wire service/distribution board. Also, installing elevators, fire pump, and circuits.  Original core and shell appliaction # 16041-10000-43434B # 16010-10000-04681	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21603	12041-10000-27180	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.20696	-118.3417	TI in an existing studio. EPC is for T24. Emergency lights are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21604	14041-10000-13219	7315 N FIGUEROA ST 101	90041	14	162A229   296	5690026025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.13628	-118.18852	plan check for power and energy. BLDG#14016-10-06374: NEW T.I. BUILD OUT 1132 S.F. BUILD OUT (N) RESTROOM, OFFICE, AND BREAKROOM FOR A HAIR CUTTING SALON.    TI  AT  SUITE  101.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21605	13041-20000-05875	333 S HOPE ST 10th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for energy and emergency lighting. restroom for high-rise commercial. 10th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21606	10041-10000-00973	8999 N BALBOA BLVD	91325	12	195B133     8	2690006011	(Q)C2-1VL	North Valley	Northridge			1151.01	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	07/20/2010 12:00:00 AM	ADDRESS	34.23353	-118.50275	removeal/installation of freezer/collers on floor  stock room. Decor alterations. roof top HVAC & refrig. equip required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21607	15041-20000-27175	333 S HOPE ST 49th floor-52th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for power and energy T.I. in existing highrise office space. Total indoor area 100,635 sqft. 850 New Branch Circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21608	19041-10000-41870	626 S LANDFAIR AVE	90024	5	135B149   325	4363006007	[Q]R4-1VL	West Los Angeles	Westwood	North Westwood		2653.05	Electrical	Electrical	Apartment			10/15/2019 12:00:00 AM	02/28/2020 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.06671	-118.44879	PV2. NEW COMMERICIAL SOLAR SYSTEM. 15.3 KW dc. / 11.4kw AC(51) HYUNDAI SOLAR MODULE HiS-S300RG (300 W)(51) SOLAREDGE POWER OPTIMIZER P320 (320 W)(1) SOLAREDGE INVERTER SE11400H-US[240V\[S|1]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21609	18041-20000-26637	9617 N LEMONA AVE	91343	7	201B145   556	2650002022	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	09/29/2018 12:00:00 AM	ADDRESS	34.24511	-118.45898	PV1.  Install 17.69 kW roof mounted grid tied PV system.  (58) modules with 11.4 and 5.0 kW rated string inverters. Portion of PV system on detached structure.  Derating of main breaker.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21610	13041-20000-32733	3715 S MCCLINTOCK AVE	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.02041	-118.29027	T24 FOR 2 EXISTING CLASSROOMS [206 AND 235].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21611	17041-10001-14866	10635 W SANTA MONICA BLVD	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.05353	-118.43031	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. CHANGE TO LIGHTING FIXTURE TYPE. PROVIDED UPDATED T24 PLANS. PC ONLY - PERMIT UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21612	16041-10000-40949	320-324 S LINCOLN BLVD	90291	11	111B145   648	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	03/02/2017 12:00:00 AM		Issued	03/02/2017 12:00:00 AM	ADDRESS	34.00107	-118.46691	PC FOR TITLE 24 ENERGY ONLY. COMMERCIAL BUILDING IN 2 STORIES BUILDING.TOTAL  1964 SQFT ( INDOORS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21613	13041-20000-34863	9201 N VANALDEN AVE PV1	91324	12	198B121   642	2762035018	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.23728	-118.54932	New Enphase M215, Photovoltaic System for an existing sfd.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21614	13041-20000-23794	333 S HOPE ST 18th Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	T24 EXISTING OFFICE HIGHRISE BUILDING. RETROFITTING FIXTURES ONE FOR ONE CHANGING TO LED. SCOPE OF WORK ON THE 18TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21615	15041-20000-37643	1301 N MONACO DR	90272	11	129B133    47	4425014013	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.05346	-118.50125	PV1, roof mounted solar panel, 13.8kW DC(46) modules: LG ELECTRONICS LG300N1K-G4, 300W(46) micronverters: ENPHASE M250-60-2LL-S2X	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21616	14041-20000-09815	6610 W LELAND WAY	90028	13	147A185   165	5547025010	RD1.5-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.09691	-118.33366	PV1.  Install 2.75 kW roof-mounted PV system, interconnect with main service panel.  Nonstandard plan.  (11) modules.  Transformerless inverter w/ power optimizers: SolarEdge SE3000A-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21617	18041-10000-02203	2300 S UNION AVE	90007	1	124-5A201 258	5124007016	C2-1L-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM			PC Info Complete	01/22/2018 12:00:00 AM	ADDRESS	34.0348	-118.28337	PC for T24 only for change of use from retail to Ice Cream shop. Total area is 455sqft. Installing new panel with new receptacles, lights and equipment. B# 17016-10000-37800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21618	17041-20000-41283	15400 W SHERMAN WAY	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.20099	-118.46839	TI to (E) commercial lobby, storage, and mail room.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21619	18041-20000-46067	1402 W HILL DR	90041	14	163-5A227  39	5691007015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.14407	-118.19543	PV1.  Install 9.0 kW DC roof mounted grid tied PV system.  (25) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21620	14041-20000-17293	6430 W SUNSET BLVD SUITE 1460	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	PC FOR T24 ENERGY ONLY. NEW LIGHTING. EXISTING OFFICES. PERMIT ISSUED UNDER THIS APPLICATION. WORK DONE IN SUITE 1460	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21621	18041-10000-13686	6600 N TOPANGA CANYON BLVD # 99D	91303	3	180B101   822	2139004019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI FOR CHANGE OF USE IN AN EXISTING RETAIL SPACE. T-24 PC FOR ENERGY ONLY SUBJECT TO FEILD INSPECTION. SCOPE INCLUDES NEW CIRCUITS. LIGHTS AND RECEPTICALS.  TOTAL AREA: 736 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21622	15041-20000-06100	18566 W LEMARSH ST	91324	12	204B125   279	2729012025	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.25481	-118.53836	Plan check for PV solar roof top mounted  with 5kW and 22 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21623	15041-20000-10152	11333 W IOWA AVE	90025	11	126B149    83	4261009026	C2-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.04502	-118.44824	Plan check for power and energy. Project scope is a tenant improvement to an existing commercial space (two-story office building). Work being done includes a 600-amp service upgrade, (1) 600-amp panel, (1) 225-amp panel, (4) 200-amp panels, and associated loads. Total lighting area =  7,419 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21624	15041-10000-17146	18040 W SHERMAN WAY 1st-& 2nd flr	91335	3	183B125   226	2121023042	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.20091	-118.52659	Full plan check for offices located in the First and second floor of a medical/office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21625	13041-20001-34587	13113 W VAUGHN ST	91340	7	216B161   621	2524005029	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	34.28487	-118.4184	EXPEDITE FEES ONLY<<<New rooftop PV Enphase system for an existing sfr.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21626	13041-20000-00166	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM			PC Approved	01/18/2013 12:00:00 AM	ADDRESS	33.97811	-118.39245	Plan check for energy only. Most lights are existing. 1329sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21627	17041-10000-08198	3800 W MT LEE DR	90068	4	159B189    10	5581010900	OS-1XL, RE40-1-H	Central	Hollywood	Hollywood United	YES	9800.09	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.13546	-118.3184	PC FOR A NEW FIRE ALARYM SYSTEM FOR AN EXISTING COMMERCIAL SPACE. SCOPE INCLUDES 37 FA DEVICES, AND  2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21628	19041-10000-24815	315 S HAMEL ROAD	90048	5	138B169   613	4334011010	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.07307	-118.38189	Design build. Energy plan check for an outdoor existing apartment building. Scope includes new lighting and equipment with a total lighting area of 2255-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21629	10041-10001-19831	6381 W DE LONGPRE AVE 1ST FL	90028	13	147A187   587	5546015040	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM			PC Approved	01/14/2011 12:00:00 AM	ADDRESS	34.09629	-118.3275	Revisioun to the approved plan. Change the quantity of lights & T24 calc. EPC is for the change. (((((((((((((INTERIOR PARTITION WALL REMODEL & TEE-BAR CEILING IN RETAIL AREA WITHIN PARKING STRUCTURE. ALSO, 4 EA LUMINAIRES INSTALL OUTSIDE IN HARDSCAPE AREAPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT)))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21630	15041-20000-02851	12468 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	33.97899	-118.41015	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21631	19041-20001-34226	4309 N IRVINE AVE	91604	2	165B169   570	2365024017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.14766	-118.38569	Expedited plan check fee.PV1.  Install 9.45 kW roof mounted and grid tied PV system and 13.5 kWh energy storage system.  (30) modules with 7.6 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21632	10041-10000-17650	1204 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.05046	-118.22698	Solar voltaic system installed on the roof of the building.  Consists of  8 modules,  8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21633	17041-10000-45037	18318 W SHERMAN WAY	91335	3	183B125   203	2125003017	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Issued	01/24/2018 12:00:00 AM	ADDRESS	34.20096	-118.53236	PC for T24 only for retail space with office spaces. Installing new lights, receptacles and equipment. Total area is 5089sqft. B# 17016-10000-27695.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21634	16041-10001-07701	1875 CENTURY PARK EAST 1200	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	PIN	34.06084104	-118.41471001	Revision to approved plan noted as Delta-1: revised qty of light fixtures, revised area of open office and corridor, added fixture F8.<<Tenant improvment, install new light fixtures and controlled receptacles in Ste. 1200. Total area 10,056 sq.ft>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21635	14041-20000-26857	9199 W THRASHER AVE	90069	4	147B169   916	5560006021	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.09552	-118.39013	NEW SINGLE FAMILY DWELLING 600AMP SERVICE. PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21636	13041-10001-34670	6179 E ST ALBANS ST	90042	14	157-5A231 342	5483016023	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.12459	-118.18455	Expedited RSES plan check per applicant request.{{PV1, Install 4.25 kw DC roof-mounted solar array for a residential house , interconnect with main panel, (1) transformerless inverter[SOLAREDGE SE3800A-US(240V)] and (17) modules[RENSOLA JC250M-24/BB]. With  power optimizer[SOLAREDGE].}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21637	17041-20000-41828	5811 N TUJUNGA AVE	91601	2	174B173   320	2338014041	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			11/17/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.17629	-118.37926	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR APARTMENT COMMON AREA. CONVERT OFFICE ROOM TO MAILROOM. ADD CONCRETE SLAB OVER EXISTING POOL TO CONVERT (E) POOL ROOM TO FITNESS ROOM /OFFICE ROOM. 1833 SQFT BUILDING PERMIT # 17014-20000-03206	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21638	10041-10000-05950	829 W BARTLETT ST	90012	1	135A213   245	5407005011	R4-1	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Apartment			04/01/2010 12:00:00 AM	04/16/2010 12:00:00 AM		Permit Finaled	08/20/2010 12:00:00 AM	ADDRESS	34.06321	-118.24524	NEW  new fire alarm system for 4-UNIT APT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21639	17041-20000-46285	15138 W FRIAR ST	91411	6	177B145    32	2242015008	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Issued	01/30/2018 12:00:00 AM	ADDRESS	34.18557	-118.46319	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. (E) solar system on site.Derating main breaker from 200A to 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21640	14041-10000-35522	5410 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.06204	-118.34668	T24 bank of america entrance lighting. Total area = 497 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21641	14041-10000-05803	101 S LA BREA AVE #104A	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.07338	-118.34425	Commercial retail TI for 1455 sq ft space.  Title 24 energy only plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21642	19041-20001-29033	11139 N MARKLEIN AVE	91345	7	210B145   102	2664010015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.27302	-118.47098	SUPPLEMENTAL PLAN CHECK, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, REMOVAL OF (2) PV MODULES ON ROOF PLAN, SINGLE LINE, LOAD CALCS, FRONT PAGE, AND CHANGE OF MAIN SERVICE PANEL LOCATION. NEW PV SYSTEM SIZE: 8.19KW DC, 7.6KW AC $0 PLAN CHECK FEE DUE TO SB1222 AND AB1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21643	18041-20000-12339	2112 W SUNSET BLVD STE I	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.07733	-118.26419	Pla check for Title 24 only in TI to (E) commercial space for beauty salon.  Total area: 1,200 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21644	13041-20000-16024	2222 S AVENUE OF THE STARS	90067	5	129B161    53	4329003***	R4-1L-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Apartment			06/18/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.05238	-118.40936	"change out of existing 800A rated equipent. equipment changeout to be like for like. existing 800 for new 800. PC for interupting rating only per applicant. this continues scope of work under application # 13041-10000-11935. this panel is named ""PD1B"" ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21645	18041-10000-15494	11949 W FOXBORO DR	90049	11	132B141   146	4404017004	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	05/25/2019 12:00:00 AM	ADDRESS	34.06058	-118.47367	PC FOR ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER with 4 poweralls (125A). PV IS EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21646	19041-20000-36771	4675 E HUNTINGTON DR SOUTH	90032	14	142-5A231  87	5213013020	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM			PC Info Complete	03/19/2020 12:00:00 AM	ADDRESS	34.08564	-118.18385	FULL PLAN CHECK FOR FIRST TIME TENANT. SCOPE OF WORK INCLUDES (1) EXISTING PANEL  AND (1) 150AMP NEW PANEL. SCOPE OF WORK INCLUDES NEW LOADS, LIGHTS, OUTLETS, AND EQUIPMENT. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 1571 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21647	15041-20000-08420	8335 W MELROSE AVE	90069	5	141B173   436	5528003198	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.0838	-118.37143	Plan check for T-24 only for retail remodeling. Total area: 4185 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21648	19041-10000-08823	101 S THE GROVE DR K70	90036	4	138B177  1131	5512003045	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.07256	-118.35874	ENERGY PLAN CHECK FOR A  RETAIL T.I. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 2,279-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21649	17041-20000-02677	6312 W TAHOE DR	90068	4	156B185    18	5577036011	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.12777	-118.32786	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 225A MSP.6.96kW ungrounded system. (29) EnPhase M250 microinverters. (29) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21650	16041-10000-10348	405 N ALVARADO ST	90026	13	138A205   299	5157016029	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM			PC Info Complete	03/24/2016 12:00:00 AM	ADDRESS	34.07065	-118.26798	(TI) to an (E) McDonalds. PC for T-24 only, total area: 984 sq.ft. indoor + 900 sq. ft. outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21651	10041-10000-08970	705 W 9TH ST 1-214	90017	9	129A207   265	5144021040		Central				2077.10	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Expired	06/01/2022 12:00:00 AM	ADDRESS	34.04607	-118.2616	INSTALL A NEW 800 AMP DISTRIBUTION BOARD, 75KVA TRANSFORMER AND A 200 AMP PANEL BOARD ON THE GROUND LEVEL FOR THE FUTURE OCCUPANTS.  CORE AND SHELL ONLY.  NO NEW LOAD ADDED. NO NEW LIGHTS INSTALLED. PLAN CHECK AND PERMIT IS FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21652	16041-20000-27253	6219 N SYLVIA AVE	91335	3	177B117   317	2128030007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.18346	-118.55254	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.68 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21653	10041-20000-14364	4721 S ALLA ROAD	90292	11	105B157   549	4212007006	P-1, [Q]MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	33.98364	-118.43043	TI IN OFFICE AREA. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21654	14041-20000-25876	3401 N LINDA VISTA TER	90032	14	142-5A235 152	5219010014	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.08498	-118.1719	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING 2 STRINGS. SINGLE TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21655	12041-20000-29696	630 E 8TH ST	90014	14	126A211   296	5145009001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			Reviewed by Supervisor	01/30/2013 12:00:00 AM	ADDRESS	34.03858	-118.24928	New 800 amp main service for a commerical tenant spaces.  New panels, lighting, loads.  Full Plan check required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21656	18041-20001-41185	16253 W LOVETT PL	91436	5	165B137    71	2284015007	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM			Reviewed by Supervisor	11/07/2018 12:00:00 AM	ADDRESS	34.15165	-118.48809	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 21.05 kWdc/18.78 kWac-CEC and consists of (3) inverters, (69) modules, (3) load centers, and (3) tesla PowerWalls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21657	12041-20000-10985	17921 W CHATSWORTH ST	91344	12	207B129   356	2715025048	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	ADDRESS	34.26509	-118.52406	"Single story commercial building.  Shell plan check for power and energy.  New 800A service.  Install general/emergency lighting tenant ""H2"" only as indicated on plans."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21658	16041-10000-05404	22222 W VICTORY BLVD BLDG F	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUDRY ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21659	19041-10000-24198	3701 W WILSHIRE BLVD # 650	90010	10	132B193    27	5503029024	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.06188	-118.30708	INSTALLATION OF WORKSTATIONS AND PRIVATE OFFICES IN COMMERCIAL HIGH RISE  BUILDINGPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21660	13041-10000-32078	1436 N VIA CRESTA	90272	11	132B125    17	4420040001	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.05685	-118.53728	][][ $0 PERMIT FEE DUE TO 2012 SENATE BILL 1222 ][][]PV1, Install 16.47 kW DC roof-mounted solar array, interconnect with service panel.Non standard plan. 61 Microinverter. Enphase M215. 61 modules solarworld SM270.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21661	13041-10001-05746	380 WORLD WAY Space T72	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	][]CHANGES MADE TO APPROVED SET OF PLANS; PROPOSED CHANGE IS FOR TWO NEW TYPE OF FIXTURES. ][][]PROPOSED 541 SQFT  TENENAT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE ( Drink LA). T72  level 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21662	14041-20000-20646	11229 N DE HAVEN AVE	91331	7	210B161   201	2533014002	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.27423	-118.41403	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(14) POWER ONE PVI 4.2 MODULES(1) AURORA 4.2KW TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21663	14041-10002-31730	734 N HENRY FORD AVE	90744	15	030B213   112	7440002034	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	33.78073	-118.24147	Supplemental for T-24 only outdoor lighting, outdoor lighting fixture are install class 1 Div 2(((((Installation of new equipment on an open air compression skid which power 2 hydrogen compressors and a hydrogen purification unit.  Conduit only variance has been filed as a misc. permit for inspection on supp application 14041-10001-31730.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21664	17041-20000-40087	18734 W VENTURA BLVD	91356	3	174B121   566	2161008005	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.17088	-118.54186	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for interior lighitng only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21665	15041-10001-22357	100 WORLD WAY TER1-SPT154FB	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	02/26/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	02-25-16 Change to approved set of plans. Changes include changes switches from dimming to regular switchs. Lighting fixtures installed are consider as task, decorative, ornamental, and display lighting; these lighting does not required dimmer. General lighting are existing and does not have to be on dimmer. Changes apply to delta 6 only. {{{{PC FOR POWER AND ENERGY. NEW RESTURANT IN LAX TERMINAL 1, TOTAL AREA 4000 SQ FT.PER APPLICANT FEE.-}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21666	16041-10001-03963	1919 S HOOVER ST	90007	1	126A201   203	5056028023	CM-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Info Complete	04/24/2017 12:00:00 AM	ADDRESS	34.03932	-118.28433	PC for a lost RTI set of plans for a NEW CVS PHARMACY . 400A 480/277V MS. total area indoor 16,688sq.ft, outdoor 33,574sq.ft. Note: Permit shall be pulled under master application PCIS#16041-10000-03963	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21667	10041-10000-12780	500 W WORLD WAY MCP-06	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/03/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-06. This applicaation separates MCP-06 from the entire project on PCIS 09041-10001-24166( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21668	19041-10001-11707	121 E 6TH ST 1-103	90014	14	127-5A211 352	5148020012	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	34.04493	-118.24918	Change to an approved set by modifying the lighting and power plan, Adding one panel and 8-ckts. All changes under delta-1 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21669	12041-20000-23211	17832 W CHATSWORTH ST	91344	12	207B129   483	2733005004	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	11/06/2012 12:00:00 AM	ADDRESS	34.2646	-118.52272	T-24 lighting plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21670	14041-10000-23741	16738 W STAGG ST	91406	6	189B137    68	2205007020	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.21299	-118.49803	Title 24 plan check only.  Total area = 24,392 sq. ft.Remove HID light fixtures and replace with new flourescent.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21671	18041-10000-31262	3015 N ROSSLYN ST	90065	13	156B209   217	5459003024	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Issued	08/17/2018 12:00:00 AM	ADDRESS	34.12139	-118.25148	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21672	19041-20001-47585	7301 N TOPANGA CANYON BLVD	91303	3	186B101   880	2023006031	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	06/24/2020 12:00:00 AM	ADDRESS	34.20301	-118.60617	PV3 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 107.8 KW DC/97.164 KW AC CEC. 4 INTERCONNECTIONS. SCOPE OF WORK CONSISTS OF (280) PV MODULES WITH (70) MICROINVERTERS AND (4) SUBPANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21673	14041-10000-27218	1522 1/2 E COLON ST	90744	15	036B213   350	7426019017	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Closed	04/20/2016 12:00:00 AM	ADDRESS	33.79175	-118.24464	INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21674	16041-10000-25731	935 W 26TH ST	90731	15	009B197   712	7463017013	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	33.72054	-118.2977	PV, INSTALL NEW 2.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 3-UNIT, APARTMENT BUILDING. (8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: SOLAREDGE SE3000A-US-ZB	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21675	13041-20000-17531	801 S GRAND AVE SUITE 1000	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			PC Approved	07/02/2013 12:00:00 AM	ADDRESS	34.04581	-118.25842	RENOVATION OF EXISTING SPACE. PC FOR T24 ENERGY ONLY. RELOCATION OF EXISTING FIXTURES. TOTAL AREA 8303 SQFT. WORK DONE IN SUITE 1000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21676	17041-20000-40744	13760 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Issued	11/09/2017 12:00:00 AM	ADDRESS	34.30934	-118.43312	Conversion of (E) 8 retail spaces into 4 retail spaces.  Plan check for energy.  Associated building permit under 17016-10000-10356	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21677	15041-10000-40210	18420 W HART ST	91335	3	183B125  1071	2125011020	M1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Issued	12/04/2015 12:00:00 AM	ADDRESS	34.19737	-118.53366	Tenant improvement for 360 Health Club.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21678	15041-10000-08799	4168 W BEVERLY BLVD	90004	13	138B197   357	5518004022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.01	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.0761	-118.30004	Kitchen remodel in (E) bar tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21679	14041-10000-18941	1805 W 6TH ST	90057	1	133-5A205 336	5154025001	C2-1	Central	Westlake	Westlake South		2089.04	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM			Ready to Issue	08/13/2014 12:00:00 AM	ADDRESS	34.05813	-118.27126	Title 24 plan check only.  Total area = 966 sq. ft.TI to existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21680	18041-20000-07751	5414 N WAMEDA AVE	90041	14	165A227   196	5691018019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	Yes	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.14471	-118.19494	Installation of (2) Tesla Powerwalls/27 kWh ESS and critical back up load panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21681	17041-10000-08639	2071 N DRACENA DR	90027	4	150B197   218	5590005038	R3-1XL	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.10973	-118.29039	PC for energy only, outdoor. Removing HID fixutres and replacing them with New LED ones. Area: 58725	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21682	18041-10001-33414	215 N TOLUCA ST	90026	1	135A209   210	5160011017	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Info Complete	10/16/2019 12:00:00 AM	ADDRESS	34.06387	-118.25728	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE ADDITION OF A METHANE SENSOR AND CHANGE OF ADDRESS. ________________________________________________________________METHANE DETECTION SYSTEM WITH 15 METHANE SENSORS AND 1 METHANE CONTROPL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21683	18041-10000-15477	7060 N AMIGO AVE	91335	3	183B121   352	2126009019	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.19911	-118.53844	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21684	18041-20000-03929	20101 S HAMILTON AVE #375	90502	15	054B197   127	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	33.84769	-118.28637	Tenant improvement to (E) commerciual office space.  Plan check for energy - 6000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21685	18041-20000-17116	6038 N JUMILLA AVE	91367	3	177B117   572	2153021013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.18041	-118.56352	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (36) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21686	16041-10000-45087	200 N VERMONT AVE	90004	13	138B197   493	5501010032	C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.07496	-118.29147	PC for energy only. Outdoor title 24. Remove HID fixture and replace with new LED fixture. Total area: 66,425.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21687	14041-20001-31652	2117 E VIOLET ST	90021	14	123A217    24	5166003012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.03269	-118.22925	Title 24 plan check only.  Total area = 1,020 sq. ft.  2008 Title 24 in effect (Building application #14016-10000-03902)  BLDG & PARKING LOT LIGHTING & GATE MOTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21688	14041-20001-04664	4714 S LINCOLN BLVD	90292	11	105B153   149	4224014018	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	33.98016	-118.43828	Modifications to approved set.  Changes to interior partitions, addition of one fixture.  Other associated changes.  Plan check for Title 24 only.  (((PLAN CHECK FOR T24 PART 6 ENERGY ONLY IN A 1,971 SQ FT COMMERCIAL BUILDING. SCOPE OF WORK < 400A. WORK ALSO INCLUDES EMERGENCY LIGHTING.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21689	17041-20000-05837	16021 W FILBERT ST	91342	7	228B141   493	2603024040	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.32407	-118.48363	PV1.  Install 8.64 kW roof mounted grid tied PV system.  (36) modules with microinverters - microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21690	12041-10000-26505	2942 N DELOR DR	90032	14	141A235   319	5217010039	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.07947	-118.17052	INSTALL ON ROOF OF SFD A PHOTOVOLTAIC SYSTEM 7.2KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21691	14041-20000-20626	12067 W PIERCE ST	91342	7	213B165   462	2531022002	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.2801	-118.39603	Roof mounted PV system with Enphase Microinverter, model M215-60-2LL.  Total system size 3.5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21692	19041-10001-37201	5006 N MEDINA ROAD	91364	3	168B105   194	2168009022	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.15929	-118.60021	(Expediate Fee) for  19041-10000-37201original scope : pc for pv-1 system. system size is 16.500kw. (50) panasonic panels with microinverter. 2-(200) combiner load centers and 1 production meter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21693	14041-20000-13276	8802 N DELCO AVE	91306	3	195B109   176	2781003014	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.2302	-118.57837	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 864 WATTS. USING ENPHASE MICROINVERTER M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21694	14041-20000-14414	15860 W YARNELL ST	91342	7	228B141    44	2582030027	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.32505	-118.47937	PV1. ROOF MOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 5.0 KW DC.(20) SW 250 MODULES(20) ENPHASE M215 MICROINVETER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21695	16041-10003-29628	10319 N NORRIS AVE	91331	7	204B165   115	2537004029	[Q]M1-1-CUGU, [Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.25712	-118.40313	"01/09/16Changes to an approved set of plans. Changes include relocating main service panel and panels ""P1"", ""P2"", and panel ""HP"" on the floor plans. All changes are clouded under delta 1.Note: Permit is paid under PCIS#16041-10002-29628"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21696	16041-20000-30563	2231 W 28TH ST	90018	10	123B189   985	5052018026	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			Reviewed by Supervisor	09/12/2016 12:00:00 AM	ADDRESS	34.03004	-118.31576	Plan check for roof-mounted solar array on a SFD. Interconnect with a 125A msp. 6kW ungrounded system. (20) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21697	15041-10000-00570	12500 W OSPREY LANE Bldg3-1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	NEW FIRE ALARM SYSTEM WITH 30 DEVICES AND1  FIRE ALARM PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21698	12041-10000-11024	338 S WESTERN AVE F	90020	4	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.01	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.06777	-118.30889	CONVERT PORTION OF EXISTING COMMERCIAL BUILDING FROM RETAIL TO MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21699	14041-20000-00300	1900 S AVENUE OF THE STARS 1200	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.05979	-118.41671	Change to lighting in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21700	18041-10001-04570	800 S LA BREA AVE	90036	4	132B181   271	5084003001	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM			PC Approved	03/08/2019 12:00:00 AM	ADDRESS	34.06027	-118.34454	Changes to an approved set of plans, Changes include revision to single line diagram, combination of two spaces, floor plan, lighting layout, circuit routing and hvac units. Note changes on all clouded areas. Delta 16 and 17__________________Full plan check for change of use on (E) Historic Building. Change of use from autoshop to microbrewery.  New service at 800A, new panelboards, total area under the scope: 9,845 sq.ft B#18016-10000-05359.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21701	18041-20000-01027	310 N FAIRFAX AVE	90036	5	138B177   379	5527037030	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.07655	-118.36127	Plan check for a PV2 roof-mounted PV system. System size is 49.7 kWdc/40 kWac and consists of (4) inverters, (1) load center, and (140) modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21702	17041-10001-33114	2245 E WASHINGTON BLVD	90021	14	118-5A217  88	5167019042	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.0191	-118.23161	"This is plan check only for T24, permit is issued under permit# 17041-10000-33114<PROVIDE LIGHTING & POWER RECEPTICLES TO TWO NEW RESTROOMSINVESTIGATION FEE PAID PER #16016-10000-10377""COMPLY WITH DEPARTMENT ORDER effective date02/09/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"">"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21703	14041-20000-20544	8016 N PASO ROBLES AVE	91406	6	189B133   336	2204030017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.2162	-118.50223	PV1 SINGLE FMAILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING CENTRAL TRANSFORMERLESS INVERTER WITH STANDARD PLAN. USING POWER OPTIMIZERS, (18) modules total.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21704	14041-10000-34292	11344 W GOSS ST	91352	6	192B173   459	2632005021	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.22222	-118.37815	Title 24 plan check only.  Total area = 4,536 sq. ft.Replace HID light fixtures with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21705	15041-10000-32032	11920 S JEFFERSON BLVD	90230	11	105B165   373	4220006043	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	PIN	33.98485065	-118.40304545	ALTERATIONS IN EXISTING OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21706	10041-10000-00075	6363 W WILSHIRE BLVD 206	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM			PC Approved	01/05/2010 12:00:00 AM	ADDRESS	34.06385	-118.3674	Replacing existing light with flourecent and track light in office building. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21707	18041-20000-20270	8071 N SEPULVEDA BLVD	91402	6	189B145   128	2654037026	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.21752	-118.46647	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21708	19041-10000-07032	414 E WASHINGTON BLVD	90015	9	123A207   245	5127019015	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Issued	02/27/2019 12:00:00 AM	ADDRESS	34.02916	-118.26118	T-24 PC FOR A TI OF A SMOKE SHOP (NO CHANGE OF USE) . SCOPE INCLUDES NEW 200A PANEL, LIGHTING AND RECEPTACLES. TOTAL AFFECETED AREA IS 700 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21709	11041-10000-25937	777 S FIGUEROA ST 12TH FLOOR	90017	9	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Expired	12/31/2013 12:00:00 AM	ADDRESS	34.04828	-118.26116	T24 Energy for office TI on 12th floor. Permit for additional ckts and panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21710	19041-20000-22169	22135 W ROSCOE BLVD LOT #12	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/19/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 12.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21711	14041-20000-17649	13720 W RIVERSIDE DR #200	91423	4	168B157   318	2269025002	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.15674	-118.43273	TI for retail store in (E) commercial shopping center.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21712	13041-10000-02139	18553 W SHERMAN WAY	91335	3	183B125    99	2118028015	[Q]C2-2D-CDO, [Q]R2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM			PC Approved	01/28/2013 12:00:00 AM	ADDRESS	34.20125	-118.53773	PC FOR ENERGY. TI TO EXISTING RETAIL. 2SPACE TO 1. SINGLE STORY. 12 new downligts . 3 new scone lights facade, and 4 new outlets for show windows. less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21713	14041-20000-24803	7000 S HOOVER ST Unit #7	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #7.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21714	15041-10000-30423	2904 W 43RD PL	90008	10	111B189    47	5023016016	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Expired	10/11/2017 12:00:00 AM	ADDRESS	34.00428	-118.32499	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.  STANDARD PLAN CENTRL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21715	12041-10000-23865	800 S FIGUEROA ST SUITE 790	90017	9	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.04771	-118.26116	TENANT IMPROVEMENT IN OFFICES-REMOVE TWO PARTITIONS TO FORM NEW OFFICE AND CHANGE LUMINAIRES USING EXISTING BRANCH CIRCUITS ANF CONTROLSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21716	10041-20000-07633	612 W 35TH PL Basement	90089	8	118-5A201   5	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/26/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.0199	-118.28239	Plan check T-24 Energy (general/emergency lighting) for TI of mechanical & storage room (basement) at USC David X. Marks Tower	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21717	18041-20000-30776	4440 W MELBOURNE AVE	90027	4	150B201  1439	5590023007	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	PIN	34.10333938	-118.28672834	PV1.  Install 2.36 kW DC/2.13 kW AC roof mounted grid tied PV system.  (8) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21718	15041-20000-31007	221 N FIGUEROA ST 5th-FLOOR	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	TI TO 5TH FLOOR. REBUILD FIRE DAMAGED AREAS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21719	14041-10001-30293	469 N EL MEDIO AVE	90272	11	126B125   531	4413009002	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.04168	-118.53506	Installation of new roof mounted solar PV array.  31 modules and 2 inverters (4 kW and 3 kW), connected to an existing 400A  panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21720	14041-10004-07239	11995 W BLUFF CREEK DR BLDG 5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	Modification to an approved set by adding (38) sensors to the detecting system.((((4/27/2015))))CHANGES TO AN APPROVED SET OF PLANS.  ADDING 11 SENSORS PER PAGE MG 4.00.METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35606.BLDG PERMIT: 13010-10000-04244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21721	12041-10001-04692	4400 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.00, 1953.00	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.09662	-118.28529	SUPPLEMENTAL APPLICATION FOR REVISION TO THE APPROVED PLAN. ALL THE CHANGES ARE SHOWEN BY DELTA 6 AND DELTA 10. REVISE LOADS AND ADD NEW BRANCH CIRCUITS. PREVIOUS PLAN CHECKED FOR AN OFFICE BUILDING. TI OFFICE RENOVATION. 40,000 SQ FT. SINGLE STORY. T24 EMERGENCY LIGHTING, POWER INCLUDED. FIRE ALARM VARIANCE ISSUED.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21722	19041-10000-11368	6931 N VAN NUYS BLVD	91405	6	183B149   491	2219026066	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.1964	-118.44898	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21723	12041-10001-06515	5550 N TOPANGA CANYON BLVD 250	91367	3	174B101   285	2146007119	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM	04/09/2012 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.17162	-118.60554	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR SUITE #250 OFFICE TI. PERMIT FOR REPLACING EXISTING LIGHT FIXTURE WITH NEW LIGHT FIXTURES ON EXISTING BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21724	13041-20000-20547	8519 W CRESCENT DR	90046	4	153B169   926	5563011009	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.11245	-118.38097	PV1 GROUND MOUNTED PHOTO VOLTAIC SYSTEM. TOTAL SYSTEM 4.25 KW. 20 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21725	18041-20000-24388	21820 W BURBANK BLVD 3floor-restroom	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Issued	07/02/2018 12:00:00 AM	ADDRESS	34.17228	-118.6032	Plan check for Title 24 only in existing restroom T.I. Total area: 628 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21726	10041-10000-05541	1600 N VERMONT AVE	90027	13	147B197   471	5542014032	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM			PC Info Complete	09/16/2010 12:00:00 AM	ADDRESS	34.09994	-118.29154	Plan check T-24 Energy outdoor lighting for exterior lighting upgrade to Chase	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21727	17041-10000-04257	10201 W PICO BLVD BLDG #311-1st,2nd fl	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	NEW OFFICE BUILDING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21728	13041-10000-29491	8612 N CALVIN AVE	91324	12	195B117   399	2783021013	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.22678	-118.55563	PV1, Installing roof-mounted 6.75KW photovoltaic system, interconnect with main panel. Transformerless inverter Solaredge SE6000A US, power optimizer, and Trina TSM-250 modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21729	18041-20000-22448	14114 W ERWIN ST Unit 1-3	91401	6	177B153   362	2240019011	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			06/15/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	PIN	34.18335277	-118.44052629	New triplex. Work includes the installation of a 600-amp service which serves (2) buildings: a duplex and a triplex. The duplex can be found under application number 18041-20000-22447.Note: Building application for the duplex can be found under 17010-20000-03093. Building application for the triplex can be found under 17010-20000-03091.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21730	16041-20001-06283	14031 W VICTORY BLVD	91401	2	180B153  1077	2238025005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			02/23/2016 12:00:00 AM			PC Approved	03/10/2016 12:00:00 AM	ADDRESS	34.18683	-118.43882	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a 3-unit residential building. Interconnect with a 200A MSP.System size: 3kW. Ungrounded system. (7) 265W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21731	13041-10000-06835	1776 E CENTURY BLVD	90002	15	091-5A213 149	6048028046	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	33.94541	-118.24162	MISSING PANELS SCHEDULES, FINAL FEE MAY CHANGE. VERIFY CIRCUITS AND FEE SCHEDULE.RENOVATION OF EXISTING DAY CARE FACILITIES. INCLUDES CLINICAL CARE FOR THE ELDERLY. PER APPLICANT'S REQUEST TO PC OSHPD III. PC FOR POWER AND ENERGY. TOTAL AREA 88504 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21732	17041-20000-16815	11036 W MOORPARK ST	91602	4	165B173   340	2423013006	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			05/19/2017 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	12/22/2020 12:00:00 AM	ADDRESS	34.15006	-118.37183	new 5 story apartment building 96 units 3000amp service.  plan check for power and energy.fire variance on file.building application number 16010-10000-05225	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21733	18041-10000-37593	4524 N DEL MORENO DR	91364	3	168A111    99	2174019004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.15405	-118.57823	PV1 11.4KW AC / 11.8KW DC roof mounted system with (40) modules and (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21734	15041-20002-36328	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM			PC Approved	03/15/2017 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plans lost at job site - this application is for recheck and reapproval of previously approved plans only.  Scope of review is for SLD and interconnection details per request of Inspector Ferguson.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21735	15041-20001-11973	2027 N HOBART BLVD	90027	4	151-5A195 235	5589001029	RE9-1	Central	Hollywood	Los Feliz		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM			PC Approved	05/13/2015 12:00:00 AM	ADDRESS	34.10752	-118.30618	Expedited per customer request.PV1. Install roof mounted PV system sized 7.8 kW. Interconnected with main service panel.(26) LG300 modules(26) Enphase C250 microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21736	12041-10000-30751	385 N WILTON PL	90004	4	138B189    54	5522029023	R1-1	Central	Wilshire	Greater Wilshire		1924.10, 1924.20	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Expired	02/17/2015 12:00:00 AM	ADDRESS	34.07827	-118.31365	PV1 Plan check for 2.45KW roof mounted photovoltaic system using Enphase M215 mircoinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21737	10041-10001-22413	12811 W SHERMAN WAY	91605	2	183B161     9	2324005033	C2-1VL	South Valley	North Hollywood - Valley Village			1233.03	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM			Ready to Issue	08/17/2011 12:00:00 AM	ADDRESS	34.20135	-118.41209	Revision to the approved plan. Change the site lights, add a bakery area and change  branch circuits. All changes are shown with CB-1. ((((((((((((((((CHANGE FROM  AN EXISTING SEAFOOD MARKET TO A GROCERY STORE FRESH AND EASY STORE ).  SCOPE OF WORK TO INCLUDE INTERIOR REMODEL, MINOR SITE OWRK, LANDSCAPING AND EXTERIOR ELEVATIONS REMODEL, RESTRIP EXISTING PARKING.  ADDITION OF MEZZANINE.))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21738	18041-20000-35473	10223 S WESTERN AVE	90047	8	091-5A193 231	6058006001	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/19/2021 12:00:00 AM	ADDRESS	33.94338	-118.30923	Change of use to medical office in single-story commercial building.  New 400A 240/120V 1ph-3w service.  Building permit under 18016-10000-17563.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21739	18041-20000-39162	23426 W HAYNES ST	91307	12	180B093   480	2036016007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.18976	-118.63752	Plan check for battery energy storage system install in to existing PV system Tesla Power Wall 2.0 13.5kWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21740	18041-10000-04122	3921 W SUNSET BLVD	90029	13	145-5A203 330	5429013002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.09235	-118.27998	A NEW 2 STORY MIXED USE CORE & SHELL BUILDING CONSISTING OF GROUND FLOOR RESTAURANT SPACE WITH OUTDOOR EATING AREA & SECOND FLOOR OFFICE SPACE.  SERVICE SIZE IS 120/240, 3PH, 800AMPS. B# 17010-10000-02572	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21741	11041-10000-25417	19755 W VANOWEN ST	91306	3	183B117  1051		(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			Corrections Issued	11/29/2011 12:00:00 AM	ADDRESS	34.19397	-118.56386	New drive-up ATM kiosk and outdoor light pole at a Chase Bank.  Full plan check requested by applicant for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21742	13041-20000-32670	12737 N GLENOAKS BLVD 9-10	91342	7	222B153   830	2508027025	QC2-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.30159	-118.44224	PC FOR T24 ENERGY ONLY. TOTAL AREA 1720 SQ FT. RELOCATION OF LIGHTING AND WALL PARTITIONS. PC REQUESTED BY APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21743	17041-10000-44322	17909 W PALORA ST	91316	5	168B129   137	2182006018	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			Reviewed by Supervisor	12/19/2017 12:00:00 AM	ADDRESS	34.15972	-118.52223	Plan check for PV roof mounted system plus battery backup system. PV system size: 6.0kW with  23 modules  and 2 Tesla PowerWall 2.0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21744	18041-10000-46409	2765 E OLYMPIC BLVD	90023	14	120A221    43	5170019003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.02378	-118.21826	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21745	12041-10000-11626	3452 W WILSHIRE BLVD	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	08/06/2012 12:00:00 AM	ADDRESS	34.0615	-118.29962	CHANGE OF USE FROM RETAIL TO RESTAURANT/RETAIL FOR NEW  2330 SF  Plan check for energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21746	14041-20001-31995	11249 N BORDEN AVE PV1	91331	7	210B161   214	2536010008	(Q)RD2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.27408	-118.40657	PC FOR UNGROUNDED SYSTEM. PERMIT ALREADY ISSUED UNDER MASTER APPLICATION. THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21747	19041-20000-30212	7660 N GLORIA AVE	91406	6	186B141    17	2206010022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	34.21008	-118.47917	New 1200A 480Y/277V 3ph-4w service, distribution, power, and lighting for change of use.  Associated building permit under 19016-10000-04849.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21748	12041-10000-28949	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM			PC Approved	12/03/2012 12:00:00 AM	ADDRESS	33.78734	-118.29768	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN A PHARMACY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21749	11041-10000-10792	4950 W SUNSET BLVD 279A and-279B	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	34.09786	-118.29745	T.1.  CONVERTING ONE EXAMINATION ROOM INTO TWO exam ROOMS ON THE SECOND FLOOR RETINAL EXAM ROOM 279A AND 279B.  TITLE 24 PLAN CHECK ONLY.  No permit to be issued on this applicaiton number.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21750	18041-20000-07645	20801 W VENTURA BLVD	91364	3	171B109    62	2166033054	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.16663	-118.58589	"""0$ permit fees due to senate bill 1222""PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 300KVA CONSISTING OF 5 INVERTERS(CHINT SCA60KTL-DO/US-480) AND 1330 MODULES(CSUN320-72P) ON 600A LOAD CENTER"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21751	16041-10000-19110	1444 W OAK GROVE DR	90041	14	159A227   120	5480027004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.13103	-118.19699	PV1 roof mounted solar system installation. Installing 20 microiverter modules rated at 215 w. Total system rating = 4.3kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21752	16041-20000-03071	601 S WESTERN AVE	90005	10	135B193   894	5503031007	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	04/08/2017 12:00:00 AM	ADDRESS	34.06328	-118.30927	Plan check for Title 24 only for Restaruant T.I. in existing space. Total area: 3,329 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21753	15041-10000-16650	18144 W DEVONSHIRE ST	91325	12	204B125   192	2731020922	[Q]PF-1XL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.25709	-118.52906	NEW SERVICE PC FOR POWER. COMPRESSED NATURAL GAS STATION LOCATED IN CITY FACILITY-HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21754	17041-10000-10667	1851 N STANLEY AVE	90046	4	150B177   522	5551012023	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM			Reviewed by Supervisor	05/03/2017 12:00:00 AM	ADDRESS	34.10384	-118.35696	PC FOR NEW SFD. PERMIT ISSUED UNDER BUILDING COMBO PERMIT. THIS IS PLAN CHECK ONLY. BUILDING SUBMITTED IN 2016	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21755	16041-10000-32783	15400 W SHERMAN WAY 3RD FLR	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.20099	-118.46839	FULL PC FOR POWER AND ENERGY. INTERIOR OFFICE TI OF ENTIRE 3rd FLOOR TO CREATE OFFICE SPACE AND BREAK ROOM.  SCOPE INCLUDES NEW PANELS, LIGHTS, AND RECEPTACLES. NEW CONNNECTED LOAD > 400A. TOTAL AFFECTED AREA IS 33017 SQ. FT.((B# 16016-10000-16024))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21756	18041-10000-09030	777 W MIRAFLORES AVE	90731	15	021B197   559	7447023012	[Q]CM-1VL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.75271	-118.29409	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21757	18041-20000-24228	5760 W ADAMS BLVD	90016	10	123B173   983	5048008031	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.03222	-118.36915	Tenant improvement of (E) commercial office space.  3081 sq ft - plan check for energy.Building permit under 18016-20000-12524	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21758	16041-10001-15492	8000 N VAN NUYS BLVD	91402	6	189B149   632	2212028019	[Q]C2-1-CDO, [Q]C2-1VL-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.2163	-118.44852	08/08/16Changes to an approved set of plans. All changes are clouded under Delta A & B. Scope includes removing/replacing lighting fixtures, and revisions to single line diagram. Note: Original application is under PCIS#16041-10000-15492((((T-24, PC FOR ENERGY ONLY. CONVERT A PORTION OF AN EXISTING RETAIL SPACE INTO OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3808 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21759	11041-20000-23901	14441 W FOOTHILL BLVD	91342	7	228B149   139	2502024013	RA-1, RD1.5-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	Apartment			11/10/2011 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.32184	-118.44856	NEW 3-STORY  9 -UNIT APT BLDG. WITH 1ST FLOOR PARKING GARAGES.  Revised plan shows overhead service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21760	18041-20001-11488	5659 1/2 E HUNTINGTON DR NORT	90032	14	147A239   344	5309027026	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	PIN	34.0969759	-118.15687406	04-26-2018 Changes to an approved set of plan. Changes include added detail conduit running below roof 18 inches. Changes has been clouded.Fees $0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21761	11041-10002-22857	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	DELTA 2 REVISION.  CHANGES TO LIGHTING LAYOUT AND REVISE T24 CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21762	13041-10000-17219	2070-2080 CENTURY PARK EAST	90067	5	132B161    39	4319001014		West Los Angeles				2679.01	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	PIN	34.05920818	-118.41153897	Remove two emergency life-safety generators (250 kW and 300 kW)  Install one generator rated 600 kW to feed two ATS (2070 and 2080 Century Park East)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21763	13041-20000-35611	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR T24 ENERGY ONLY. NEW LIGHITNS EXISTING STUDIO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21764	11041-10000-03647	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	"TENANT IMPROVEMENT ON EXISTNG OFFICE AREA ""TIME WARNER"". PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21765	14041-10000-28546	161 S LA BREA AVE	90036	5	138B181  1136	5513019038	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	10/20/2014 12:00:00 AM	ADDRESS	34.07185	-118.34424	Tenant improvment in existing retail spacePlan chk is for Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21766	19041-10000-43777	14941 W FRIAR ST	91411	6	180B145   877	2242017027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.18582	-118.45893	NEW PV1 ROOF TOP INSTALLATION WITH SYSTEM SIZE OF 8.775 kW DC/7.6 kW AC, WITH A SOLAR EDGE CENTRAL INVERTER (SE7600H-US), 27 MODULES (Q. PEAKDUO-G5. 325),  AND INCLUDING 27 OPTIMIZERS (SOLAR TECH. P320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21767	13041-20000-08966	6420 W WILSHIRE BLVD STE 1420-STE 1450	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for energy and emergency lighting. High-rise commercial. Ste 1420 and Ste 1450.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21768	10041-10000-16220	8480 W BEVERLY BLVD # A105	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	09/30/2011 12:00:00 AM	ADDRESS	34.07577	-118.37599	ALTERATIONS IN COMMERCIAL SPACE, PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21769	11041-10001-27429	435 N BEACHWOOD DR PV1	90004	4	138B189    28	5523032021	R1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2012 12:00:00 AM			PC Approved	03/16/2012 12:00:00 AM	ADDRESS	34.07847	-118.3218	PLAN CHECK ONLY FOR 6.9KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM. SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21770	19041-10000-46121	6430 W SUNSET BLVD #101	90028	13	147A187   154	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.09782	-118.32979	T-24, ENERGY PLAN CHECK. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN AN EXISTING SPACE. TOTAL SQUARE FOOTAGE: 2,369.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21771	14041-10000-19089	13031 W JEFFERSON BLVD BLD #500	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	33.97451	-118.42531	PC FOR POWER AND ENERGY. TI. VERIZON OFFICE. TOTAL AREA 47280 SQ FT. BUILDING # 500	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21772	11041-10000-25068	865 S FIGUEROA ST 23rd FL	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.04653	-118.26275	remodeling office spacesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21773	19041-10000-17303	7921 W 81ST ST	90293	11	096B153   206	4115027018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	33.9612	-118.43431	(ePlan) Install 1 Energy Storage System @13.5KWH & 1 New 125A Load Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21774	17041-10000-12210	535 W 130TH ST	90061	15	081B201   308	6132003026	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	33.91452	-118.28422	PC for energy only, Outdoor Title-24. Remove HID and Install new LED fixtures. Area: 20,550 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21775	13041-20000-35636	11554 W CANTON DR	91604	2	159B169   356	2377016018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.13293	-118.38551	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 2 TRANSFORMERLESS INVERTERS, NONSTANDARD PLAN. ALL ROOF MOUNTED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21776	15041-20000-14678	10018 N SHOSHONE AVE	91325	12	204B129   454	2734017009	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Expired	06/08/2017 12:00:00 AM	ADDRESS	34.25302	-118.51734	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21777	15041-10000-06007	20954 W OSBORNE ST	91304	3	195B109    58	2779002088	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.23292	-118.59032	replacing HID luminaires in existing warehouse with LED luminairesPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21778	13041-10000-25919	1643 N CAHUENGA BLVD	90028	13	148-5A187 201	5546007027	C4-2D-SN, [Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.101	-118.32968	TITLE 24 PLAN CHECK ONLY. TI FOR RESTAURANT. PREVIOUSLY RESTAURANT. 1444 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 1STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21779	17041-10000-20551	9565 W LA CANADA WAY	91040	7	207B181   186	2549011007	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.26151	-118.34118	PV1, ROOF SOLAR MOUNTED SYSTEM USING A CENTRAL INVERTER. SYSTEM CONSIST OF 20 MODULES AND (1) SOLAR EDGE INVERTER 3800. TOTAL SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21780	16041-10000-43645	1041 W BLOOMWOOD ROAD	90731	15	024B193   536	7442026004	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	33.75816	-118.30021	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.0KWac.(25)AC MODULES-SPR-X22-360-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21781	17041-10000-20155	14247 W DELANO ST	91401	6	177B153   400	2240020028	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.18283	-118.44376	Installation of fire alarm system in new 2 story 5 unit apartment building.  Total system size = 25 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21782	11041-20000-26899	1115 S ALVARADO ST	90006	1	129A201    14	5136018902	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	34.04969	-118.28139	Revisins to 11041-20000-13095	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21783	14041-10000-32428	6801 W HOLLYWOOD BLVD C2-263	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I. REMODEL OF (E) RETAIL SPACE INCLUDING FLOORING, CEILINGS, PARTITIONS, DOORS, FINISHES, ETC. MEP WORK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21784	16041-20000-35624	345 E 51ST ST	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	33.99665	-118.26853	Plan check for energy only. New single story office/storage maintenance building. New lighting (incl. emergency) and receptacles. T24: indoor - 2760sqft; outdoor - 16580sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21785	16041-30001-26313	12628 N AMBOY AVE	91342	7	219B145    37	2604015021	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.30082	-118.47175	EXPEDITE PER APPLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21786	15041-20000-36439	1030 S ROBERTSON BLVD	90035	5	132B169   296	4332016042	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.0582	-118.38345	PV2. NEW ROOF-MOUNTED SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 15KWac.(46) MODULES-SILIKEN #KLK60P6L-240(3) INVERTERS-SUNNY BOY 5000-US(1) 100A SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21787	14041-10000-02417	1115 S WALL ST #4	90015	14	124-5A209  91	5145023036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.03613	-118.25465	Remove HID light fixtures and replace with new fluorescent fixtures in a retail space.  Title 24 plan check for fixture one-for-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21788	10041-20001-23602	110 S FAIRFAX AVE # A14	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM			PC Approved	12/20/2010 12:00:00 AM	ADDRESS	34.07371	-118.36119	Revision to approved plans. Revision to T24 energy calculations. energy plan check freshii	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21789	13041-10000-07550	10476 W KINNARD AVE	90024	5	132B157   472	4326030008	R1-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.05863	-118.42746	methane zone. PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. CHANGE FROM STANDARD PLAN. TOTAL OF 24 MODULES, MICROINVERTER ENPHASE M215. USING BATTERY BACK UP to INtERACTIVE INVERTER inside prewired midnite solar enclosure. TOTAL SYSTEM SIZE 5.18KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21790	13041-10002-11563	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Expired	03/09/2017 12:00:00 AM	ADDRESS	34.09818	-118.32309	Modifications to approved set.  Additional 800A distribution equipment.   Revised lighting layout.  Relocation of distribution equipment and loads.  (((AS PART OF THE COLUMBIA SQUARE REDEVELOPMENT, TWO BUILDINGS SHARING A CONNECTING CANOPY WILL HAVE THE CANOPY REMOVED. A BUILDING PERMIT WAS ISSUED FOR  EACH BUILDING-6125 W SUNSET BLVD HAVING 6 FLS AND 6121 W SUNSET BLVD HAVING THREE FLOORS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21791	10041-20000-05655	21155 W CALIFA ST SUITE-A	91367	3	177B105   104	2149002026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/20/2010 12:00:00 AM	ADDRESS	34.17716	-118.59277	T.I WORK IN OFFICE AREA OF A ONE STORY BUILDING. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21792	15041-20001-06428	5425 N DENNY AVE	91601	2	174B177  1017	2416016030	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	06/17/2015 12:00:00 AM	ADDRESS	34.16924	-118.36472	06-17-2015 Change to approved set of plans. Changes include relocate switch gears MSA (600A) [[[[[PC FOR POWER AND ENERGY. NEW 8-UNITS, 2-STORY APARTMENT BUILDING ON GRADE LEVEL .]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21793	12041-20000-07100	8220 N WOODMAN AVE radiology-rec	91402	6	192B157   780	2213021019	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM			PC Approved	03/28/2012 12:00:00 AM	ADDRESS	34.22035	-118.43224	energy plan check kaiser office space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21794	17041-20000-09897	12601 W PIERCE ST Bldg 14	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 14).3.0kW ungrounded system. (14) modules with 3.0kW rated string inverter with DC optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21795	14041-20000-35182	5815 W SUNSET BLVD Suite 302	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Issued	12/29/2014 12:00:00 AM	ADDRESS	34.09822	-118.31613	Plan check for energy only. TI for office. Title 24 for lightning and receptacles. 2,230 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21796	14041-10000-07494	2416 E 16TH ST	90021	14	118-5A217 104	5168009010	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.01961	-118.22961	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 8416 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21797	18041-10000-35913	888 S FIGUEROA ST # 850	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.0465	-118.26225	RENAT IMPROVEMENT IN OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21798	15041-10000-26936	17600 W DEARBORN ST	91325	12	198B129   360	2766008018	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.23752	-118.51831	PV 1 solar system for a single family home. the scope of work includes (2) inverters: total 12KW, (1) load center : 100A, (40) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21799	17041-10000-28670	263 S LA BREA AVE	90036	5	135B181   160	5513022001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Issued	08/14/2017 12:00:00 AM	ADDRESS	34.06925	-118.34422	PC FOR REPLACE LIGHTS TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21800	13041-10000-14412	9420 N RESEDA BLVD	91324	12	198B125   131	2764010041	(Q)C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	07/09/2013 12:00:00 AM	ADDRESS	34.24152	-118.53589	pc for energy only. less than 400a and no emergency lighting per applicant. NONSTRUCT INT T.I. & CHANGE OF USE FROM RETAIL./RESTAURANT TO RESTAURANT - 1,467SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21801	15041-10000-26583	5700 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	Plan check for fire alarm panel replacement; scope includes (1) fire alarm panel,  (3) communication panels and (8) annunciators devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21802	14041-20001-21732	4503 S GLENCOE AVE 100-150	90292	11	105B153    96	4212007009	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM			PC Approved	08/10/2015 12:00:00 AM	ADDRESS	33.98462	-118.43524	08-10-15 Change to apporved set of plans. Changes include Delta A and removed inverter(5KVA) and transfer 3 emergency circuits to ELA panel. [[[[[T.I to existing two story commercial building.  Removal and additional subpanels, branch circuits, and lighting.  Plan check for power and energy.]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21803	15041-10001-13125	2630 S ALMA ST	90731	15	009B197   863	7463017005	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM			Verifications in Progress	06/23/2015 12:00:00 AM	ADDRESS	33.72005	-118.29889	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 2.86 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(11) MODULES: KYOCERA KU2606XPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21804	19041-20000-36354	5115 W WILSHIRE BLVD	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			09/12/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.06233	-118.34134	New lighting and lighting controls for interior remodel of existing leasing office and fitness center.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21805	13041-10000-23142	1418 S THAYER AVE	90024	5	132B157   292	4326017028	R1-1	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM			Verifications in Progress	04/22/2014 12:00:00 AM	ADDRESS	34.05986	-118.4293	ROOF-MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE: 2.94 KW, TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS, UNGROUNDED SYSTEM IN A 2-STORY HOUSE.(12) MODULES:  TRINA SOLAR #TSM-245PC05/PA05.18(1) INVERTER: SOLAREDGE # SE3000A-US(12) OPTIMIZERS: SOLAREDGE #OP250-LV-MC4SM-2NA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21806	14041-10000-33501	1522 W 11TH PL	90015	1	129A203   376	5137025009	R4-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.04641	-118.27461	Installation of new roof mounted solar PV array.  3 inverters with 88 modules (8 strings) with total system size = 20.4 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21807	13041-20000-33624	1701 S BUCKINGHAM ROAD	90019	10	126B185   334	5071010024	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.04361	-118.33444	Installation of Solar System 8.32kw for an existing single family dwelling.  Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21808	17041-20002-42117	7242 N VALJEAN AVE	91406	6	186B137   367	2205027029	MR1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.2024	-118.48575	Placard modification and swapping the performance meter and AC disconnect locations.  $0 plan check fee per State Senate Bill SB 1222. (((PV2.  Install 50.66 kW DC roof mounted grid tied PV system.  (149) modules with (2) 24kW string inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21809	18041-20000-41810	13760 W WEDDINGTON ST	91401	4	171B153   356	2247015013	RA-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Issued	10/31/2018 12:00:00 AM	ADDRESS	34.16656	-118.43302	pv1install roof mounted pv system sized 15.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21810	10041-10000-09591	833 S WESTERN AVE	90005	4	132B193   649	5093003024	C2-1	Central	Wilshire			2126.20	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM			PC Info Complete	05/20/2010 12:00:00 AM	ADDRESS	34.05742	-118.30925	ti for resturant , all lights existing. no title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21811	10041-20000-22512	3101 S OVERLAND AVE Unit #D	90034	5	123B161   857	4254011039	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	05/18/2011 12:00:00 AM	ADDRESS	34.03044	-118.41627	"First time occupancy in unit #""D"".   Plan check is for power.   (T-24 missing)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21812	12041-10000-09522	3801 N LONGRIDGE AVE	91423	5	162B161   538	2385007019	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	07/02/2012 12:00:00 AM	ADDRESS	34.13975	-118.41848	Plan check for new 9.6KW roof mounted photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21813	10041-10000-10470	2484 N BANYAN DR	90049	11	141B133   136	4492027002	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2010 12:00:00 AM	08/26/2010 12:00:00 AM		Permit Expired	11/28/2012 12:00:00 AM	ADDRESS	34.08197	-118.50586	New Natural Gas Fuel Cell (ClearEdge) for single family dwelling. Plan check for power. LAFD approval not required per LAFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21814	18041-20000-26326	10859 W OXNARD ST	91606	2	177B173   939	2414005002	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Issued	07/13/2018 12:00:00 AM	ADDRESS	34.17956	-118.36774	Plan check for Title 24 only. Project site is a suite on the second floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,742 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21815	18041-20000-05449	19234 W KINZIE ST	91324	12	201B117   277	2762005003	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.24804	-118.55269	PV1.  Installing 13.00 kW DC roof mounted grid tied PV system.  (2) 6kW rated central inverters with (40) 325 W PV modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21816	16041-10000-06296	21013 W SHERMAN WAY CORN N'-CRAB	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.20125	-118.5914	"PLANCHECK FOR T24 ENERGY. CHANGE OF USE RETAIL TO RESTAURANT. ""CORN N' CRAB "" 2,087 SQ. FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21817	18041-10000-28031	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC FOR NEW Z-PURGING CONTROL PANEL AND LINE VOLtaGE CIRCUITS IN HAZARDOUS  LOCATION CLASS I DIV. 2B#18016-10000-23106	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21818	18041-10002-18137	2714 S FORRESTER DR	90064	5	126B165   197	4308006019	R1V2-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM			PC Approved	12/31/2018 12:00:00 AM	ADDRESS	34.04379	-118.40398	CHANGES INCLUDE THE ADDITION OF A DISCONNECT UNDER CLOUDED AREA, DELTA 1. ________INSTALL A 40.5 KWH BATTERY STORAGE SYSTEM TO AN EXISTING SOLAR SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21819	13041-10000-00492	4252 N RHODES AVE	91604	2	165B165   709	2367007002	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.1483	-118.40289	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A 2 STORY HOUSE. 42 MODULES IN 5 STRINGS USING 2 INVERTERS. SYSTEM SIZE IS 10.5 KW.  [MODULES: TRINA SOLAR # TSM-250PA05.8  |||| INVERTERS: POWER-ONE # PVI-3.8-I-OUTD-S-US-NG (NEGATIVELY GROUNDED)  AND POWER-ONE # PVI-3.0-OUTD-S-US (TRANSFORMERLESS) ]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21820	17041-10000-36262	1237 W SEPULVEDA ST	90732	15	018B193   671	7452006008	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Issued	10/10/2017 12:00:00 AM	ADDRESS	33.74504	-118.30295	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING METAL HALIDE FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 23300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21821	13041-20000-25298	1251 W 186TH ST	90248	15	060B197   232	6109008018	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Expired	05/07/2015 12:00:00 AM	ADDRESS	33.8621	-118.29611	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.6 KW AC USING 17 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21822	14041-10000-11501	10537 W CHANDLER BLVD	91601	2	171B177    70	2417002008	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Expired	05/25/2016 12:00:00 AM	ADDRESS	34.16881	-118.3607	PV1 4KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(16)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21823	16041-10000-10125	10833 W VICENZA WAY	90077	5	147B149   385	4377037005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Expired	04/24/2018 12:00:00 AM	ADDRESS	34.09826	-118.45863	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER. (30) MODULES, MITSUBISHI PV-MLE265HD, AND (1) INVERTER, UNO-7.6-TL-OUTD. TOTAL SYSTEM SIZE IS 7.6KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21824	16041-20000-12774	6240 W FOOTHILL BLVD	91042	7	198B205   182	2572001028	(T)(Q)C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.24093	-118.26727	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR PART OF ALBERTSONS. 8463 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21825	17041-10000-43816	11356 W DONA LOLA DR	91604	2	159B173   400	2380017022	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.13224	-118.37858	NEW ROOFTOP SOLAR SYSTEM WITH 52 MODULES (SILFAB SLG-M 370 WATT) AND 52 MICROINVERTERS (ENPHASE IQ6PLUS-72-2-US). SYSTEM SIZE IS (19.24KWdc/15.08KWac).Inspection to verify that existing 200A service from DWP remains and only a new 400A panel with 200A main breaker is installed.  ZERO PERMIT FEES DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21826	18041-30000-46958	3618 S DUNN DR	90034	5	120B165   414	4313008040	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.02683	-118.4024	NEW FIRE ALARM SYSTEM FOR AN APARTMENT LOW RISE BUILDING. (1) FA DEVICES AND (132) FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21827	18041-10000-36230	4201 W WILSHIRE BLVD 2ND FLR	90010	4	135B189   972	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.06189	-118.31911	TI IN EXISTING RESTROOMS ON THE 4TH FLOOR.T-24 ENERGY ONLY.   BUILDING PERMIT: 18016-10000-28071	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21828	14041-20001-01330	5033 N ORRVILLE AVE	91367	3	171B093   728	2047012035	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.16226	-118.64388	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 12KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21829	17041-10001-25698	3902 W SUNSET BLVD	90029	13	147A191    82	5545015001	[Q]C2-1VL, [Q]C4-1	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.0917	-118.27988	(Supplemental PC for lost set of plans all fees are based on supplemental)TITLE 24 PLAN CHECK FOR TENANT IMPROVEMENT (RETAIL TO RETAIL). TOTAL AFFECTED AREA 1375 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21830	14041-10000-30320	14135 W SHERMAN WAY	91405	2	183B153     7	2217030027	(T)R3-1, R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Issued	11/12/2014 12:00:00 AM	ADDRESS	34.20136	-118.44147	Title 24 plan check .  Total area = 116060 sq. ft.Installation of outdoor lighting for a park area.  One new 100A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21831	19041-20003-17480	7501 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.20692	-118.49233	$0 plan check fee due to SB1222 and AB1414supplemental plan check only, for changes to approved set, clouded delta 1 changes only. changes to roof plan page, single line, and addition of a cutsheet. single line arrangement changed and addition of a feeder schedule and change to feeder sizes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21832	17041-10000-20220	2964 N BEVERLY GLEN CIR	90077	5	156B153    17	4382030065	RE15-1VLD-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.12788	-118.44376	MARKET TI. PC FOR T24 ENERGY ONLY. LIGHTING UPGRADES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21833	12041-10002-06871	639 N NORTH BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM			Corrections Issued	05/12/2012 12:00:00 AM	ADDRESS	34.05972	-118.2398	PROVIDE 400 AMP TEMP POWER TO JOB SITE WITH STEP DOWN TRANSFORMER.  LOAD IS GREATER THAN 400A.  PLAN CHECK REQUESTED BY INSPECTOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21834	17041-10000-39551	1438 W 254TH ST	90710	15	036B193   526	7410006044	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Apartment			11/01/2017 12:00:00 AM			Reviewed by Supervisor	11/09/2017 12:00:00 AM	ADDRESS	33.79368	-118.30248	Install new PV1, rooftop solar system 3kW AC on a SFD, (7) modules and (1) inverter. Also install (1) ESS Tesla powerwall 13.5 kWh	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21835	11041-10001-27684	10227 N MASON AVE 1-50	91311	12	204B109   215	2741025038	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Apartment			07/16/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.25626	-118.58016	Modification to approved set to add addtional devices.                  <<<<<<New Fire alarm system for new apartment building.Note: Electrical Plan under 11041-10000-25644>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21836	12041-20000-23725	12100 W WILSHIRE BLVD	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM			Ready to Issue	10/04/2012 12:00:00 AM	ADDRESS	34.0438	-118.46755	T.I. to an existing office building in a high-rise building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21837	10041-20000-06585	12265 W VENTURA BLVD	91604	2	162B165   111	2367017016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.14328	-118.40035	"T. I for restaurant. Lighting and power. This plan check is title 24 energy only. COMPLY WITH DEPARTMENT ORDER effective date05/19/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21838	17041-10000-29842	830 S GREEN AVE	90017	1	130-5A205 242	5142019013	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.05111	-118.27126	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21839	15041-10001-30430	503 S MAIN ST	90013	14	129A211   155	5149037010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	ADDRESS	34.04665	-118.24887	12/03/2015\CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES ON DELTA 1, CHANGES INCLUDE THE INSTALLATION OF A DIFFERENT FIXTURE TYPE AND REMOVAL OF FIXTURES BY THE STORE FRONT. (((Energy plan check for a grocery store. Scope includes new lighting, receptacles and equipment; total area is 2030-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21840	18041-20000-09820	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.23911	-118.3725	Plan check for a PV2 roof-mounted FiT PV system. System size is 654 kWac/721 kWdc and consists of (7) inverters, (1,879) modules, and (2) load centers.Fees $0 due to California Senate Bill 1222 Solar Roof Top	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21841	16041-20000-09404	17532 W SUPERIOR ST	91325	12	201B129   281	2755009020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.2466	-118.51692	Plan check for a PV1 roof-mounted PV system. System size is 8 kWac and consists of (2) inverters, (37) modules, (1) load center, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21842	13041-20000-20521	5990 N SEPULVEDA BLVD 203	91411	2	177B145   487	2243019023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.17911	-118.46588	T24 FOR EXISTING OFFICE SPACE PART OF A HIGHRISE BUILDING. TOTAL SQRFT 7449. PERMIT HAS ALREADY BEEN PULLED UNDER APPLICATION NUMBER: 10341-90000-18486	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21843	14041-10000-11099	1499 S ROBERTSON BLVD	90035	5	129B169   296	4305014056	C2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.0524	-118.38428	Remove HID light fixtures and replace with new fluorescent fixtures. TOTAL AREA 1085 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21844	16041-10000-44419	8047 S FORDHAM ROAD	90045	11	099B157   200	4113020020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	33.96463	-118.4189	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. PC FOR AC MODULES SYSTEM USING 12 MODULES. TOTAL RATING 4.3KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21845	16041-20001-02884	7900 N BALBOA BLVD BLDG 'J'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	4.13.2016 - Plan check for modifications to approved set. Change size of breakers feeding panels G3, G4, G5, G7, and G8 from 40A to 60A, and update each panel's feeder sizes. Remove T.C. detail from sheet E-5.===Plan check for power and energy Aircraft Hangar Building 'J' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' J' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21846	11041-20000-11342	6740 N SEPULVEDA BLVD	91411	6	180B145    39	2235004009	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	PIN	34.19340436	-118.46533373	PLAN CHECK FOR T24 ENERGY (GENERAL/EMERGENCY LIGHTING) FOR TENANT IMPROVEMENT TO SUBWAY RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21847	18041-20000-29731	6513 W LAKERIDGE ROAD	90068	4	156B185   114	5577020013	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.12335	-118.33771	PV1.  Plan check for PV roof mounted system, system size: 15.2kW with 56 modules and 2 inverters(7.6kW AC).$0 permit fee per State Senate Bill SB 1222 as amended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21848	14041-20001-34337	19020 W DEVONPORT LANE	91356	3	162B121    15	2177040016	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM			PC Approved	01/06/2015 12:00:00 AM	ADDRESS	34.14184	-118.54799	expedite feesPV1. INSTALLING ROOF MOUNTED. 18.5 AC KW SYSTEM SIZE. (64) SUNPOWER SPR-E20-327(1) SMA SB8000-US-22(1) SMA SB70000-US-22(1) SMA SB3000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21849	16041-10000-04045	7330 S WESTLAWN AVE	90045	11	102B161    91	4110028024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	33.9741	-118.41104	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (22) MODULES (1) 3.6 (1) 3.0 INVERTER. TOTAL SYSTEM SIZE IS 6.6KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21850	15041-10000-35046	7207 W MELROSE AVE	90046	5	141B181   551	5525011013	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.08362	-118.34651	Energy plan check for removing HID light fixture and replace with LED fixture in a commercial building, retail.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21851	19041-20000-37995	12823 W FOOTHILL BLVD	91342	7	216B161     7	2514004028	M1-1-CUGU	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	10/21/2020 12:00:00 AM		Permit Finaled	08/29/2023 12:00:00 AM	ADDRESS	34.29258	-118.41394	$0 FEE PER AB1414PV3.  Install 128.76 kW DC roof mounted grid tied PV system. (290) modules with 50 and 62 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21852	18041-20000-01103	21300 W VICTORY BLVD Suite 120	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,282 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21853	13041-10000-12781	861 N LA CIENEGA BLVD	90069	5	144B173   404	4337002048	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.08698	-118.37659	pc for power and energy. TI UPGRADE SERVICE FROM SEVERAL separate services TO 800A. EXISTING BLDG. RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21854	10041-10000-10518	1800 S MAIN ST	90015	9	123A207   102	5127024009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.03196	-118.26368	New tenant. Club house. Lighting and power. new 800 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21855	16041-20002-07736	7858 N LANKERSHIM BLVD	91605	6	189B169   482	2311015001	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.21372	-118.38757	5/4/2017changes to an approved set of plans.  changes noted delta 1.  changes include revised energy calculations.this is plan check only.(((((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to an auto repair shop. Total lighting area = 2,184 sq. ft.)))))Note: Building permit has been issued under 14014-20000-04435	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21856	12041-10000-17656	950 W JEFFERSON BLVD	90089	8	120A201    20	5039003027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	ADDRESS	34.02484	-118.2869	New lighting and receptacles for an existing office space.  Load is less than 400A.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit Fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21857	10041-20000-10817	5750 W WILSHIRE BLVD 4TH FLOOR	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	08/31/2010 12:00:00 AM	ADDRESS	34.06227	-118.3542	LIGHTING AND POWER FOR OFFICE AREA. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21858	15041-20000-37008	6558 N NAGLE AVE	91401	2	180B157   510	2329025020	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Expired	12/07/2017 12:00:00 AM	ADDRESS	34.19002	-118.42348	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (17) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21859	13041-20000-34312	1043 S ABBOT KINNEY BLVD	90291	11	108B145   979	4239021019	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	33.99203	-118.47099	Retail - change to lighting in an existing 2-story building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21860	18041-20000-24483	2129 1/2 W LAVERNA AVE	90041	14	160-5A221 269	5685010011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Issued	06/29/2018 12:00:00 AM	ADDRESS	34.13329	-118.21471	pv1install roof mounted pv system sized 7.6kw AC/ 6.6kw DC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21861	16041-20000-38045	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.23162	-118.58832	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR AEROJET ROCKETDYNE. 12183 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21862	18041-10000-03018	9272 W ROBIN DR	90069	4	147B169   216	5561006026	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.10119	-118.39142	PC FOR POWER TO A SFD. THIS IS A REDESIGN FOR  A PREVIOUS APPROVED SET  SERVICE SIZE 1200A 120/208 3PH.SCOPE INCULDES NEW PANELS, CIRCUITS AND EQUIPMENT. THIS FALLS UNDER 2011 NEC DUE TO BUILDING PERMIT. B# 13010-10000-00400	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21863	16041-10000-23044	23701 W VANOWEN ST	91307	12	180B093    97	2034001036	[Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	34.19343	-118.64279	PC for energy only to existing retail 7 eleven store single story. Adding new lighting only. Total sqft = 1489	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21864	14041-20000-06426	4108 S DEL REY AVE	90292	11	108B153  1200	4230005040	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	33.98836	-118.4448	PV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 64.2KW AC USING MULTIPLE INVERTERS WITH MULTIPLE STRING INPUTS. USING TOTAL OF 284 MODULES($0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21865	15041-10001-26639	2310 N APOLLO DR	90046	4	153B177   463	5569008027	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.11295	-118.36424	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. <<PV1, INSTALL NEW 17.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(66) MODULES: KYOCERA KU2606XPA(2) FRONIUS IG PLUS A 7.5>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21866	15041-20000-07718	9355 N ARLETA AVE	91331	6	198B157   399	2625018002	RA-1, RS-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.24011	-118.42428	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system. (12) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21867	15041-20000-05987	4600 N COLDWATER CANYON AVE	91604	2	168B161   906	2362019013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			03/02/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.15402	-118.4136	Plan check for power and Title 24 (energy).  Total area = 21,011 sq. ft. (indoor) + 4,049 sq. ft. (outdoor)New 4 story 32 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21868	19041-10000-48122	5551 E HUNTINGTON DR NORTH	90032	14	147A239   286	5309024002	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	08/29/2020 12:00:00 AM	ADDRESS	34.09487	-118.15901	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21869	10041-10000-00454	1520 W FLORENCE AVE	90047	8	102B193  1364	6018006003	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	01/28/2010 12:00:00 AM		Permit Closed	04/07/2010 12:00:00 AM	ADDRESS	33.97441	-118.30322	New 200 amp service, panel, circuits, and lighting to existing commercial building.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21870	16041-10003-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.23567	-118.5584	"THIS IS PLAN CHECK ONLY!DELTA ""3R1"" CHANGES TO APPROVED PLANS DATED 6/14/2018. SCOPE OF WORK INCLUDES THE CHANGE OF LIGHTING LAYOUT IN THE CORRIDOR SPACES, REVISIONS TO PHOTOMETRIC IN ALL AFFECTED AREAS, CHANGES TO AIC RATING IN THE RESIDENTIAL SECTION FROM FULLY RATED TI SERIES RATED AND CHANGES TO BREAKER SIZES IN THE UNITS PANEL FROM 20A TO 15A.  <<<PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE  APARTMENT WITH 215UNITS.   AND RESTAURANT/ RETAIL CORE & SHELL.  FOUR FLOORS OF RESIDENTIAL OVER TWO FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL. THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMP, 4000 AMP, AND 1600 AMP.  TOTAL AREA = 408,828 SQ. FT.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21871	19041-20000-23047	14921 W OTSEGO ST	91403	4	171A149   150	2263005006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/27/2019 12:00:00 AM	ADDRESS	34.16308	-118.45818	Plan check for Energy storage system, Energy storage system size: 27KWh wiht 2 Tesla Power Wall 2.0 (13.5KWh) installed in to existing PV system	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21872	17041-20001-12005	415 S BERENDO ST	90020										Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	08/01/2017 12:00:00 AM	ADDRESS	34.06681	-118.2943	expeditepv2install roof mounted pv system sized 48kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21873	17041-20000-11703	8833 N RESEDA BLVD	91324	12	195B125   466	2770016008	C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.23172	-118.53627	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 648.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21874	19041-20000-05366	9937 N SHOUP AVE	91311	12	201B101    43	2745010033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.25106	-118.61506	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 39 MODULES (SUNPOWER SPR-X22-370D-ACMODULE) AND 39 MICROINVERTERS (SUNPOWER SPR-X22-370-D-AC). SYSTEM SIZE IS 12.4KWAC and 14.43KWDC.Fees $67.63 due to California Senate Bill 1222 and AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21875	17041-10000-08154	9915 S BROADWAY	90003	8	091-5A203  53	6053018007	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	33.94578	-118.27851	T-24, TENANT IMPROVMENT (2,124 SQ.FT.) TO THE  RETAIL/FAST FOOD RESTAURANT (7-ELEVEN). SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21876	10041-10001-00573	801 N FAIRFAX AVE #108 & 109	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM			PC Approved	04/15/2010 12:00:00 AM	ADDRESS	34.08567	-118.36172	CHANGES TO APPROVED PLANS.  REDUCED AND CHANGED LIGHT FIXTURES. PLAN CHECK IS FOR TITLE-24 ENERGY CALCS IN A PET STORE.    BUILDING PCIS# 09016-10000-21432.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21877	14041-20000-25781	1840 S CENTURY PARK EAST 5th floor	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI to 5th floor restrooms.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21878	12041-20000-12564	350 S FIGUEROA ST	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.05438	-118.2549	s.700 T.I.ENERGY. EMERGENCY( 176 A new added load )Request for Modification to separate Fire Alarm system filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21879	18041-10000-23128	550 S PALOS VERDES ST	90731	15	015B201    36	7455026048	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Apartment			06/21/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	33.73963	-118.28119	INSTALLATION OF A FIRE ALARM SYSTEM. 2 FACP, 19 RPS, 1141 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21880	17041-20000-12165	636 N VISTA ST	90036	5	141B181   684	5526019026	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.08298	-118.3521	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21881	17041-10000-45977	6323 N WOODMAN AVE	91401	2	177B157    14	2239006010	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.18568	-118.43146	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21882	19041-10000-41572	445 S FIGUEROA ST 28TH FLR	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	ENERGY PLAN CHECK FOR RESTROOM RENOVATION LOCATED ON THE 28TH FLR OF A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING OF  360 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21883	14041-20000-13741	5411 W BLACKWELDER ST	90016	10	120B177   183	5043016011	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Expired	07/08/2016 12:00:00 AM	ADDRESS	34.02822	-118.36214	PV1.  Install 4.25 kW roof-mounted utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21884	18041-20000-28053	18370 W BURBANK BLVD #707	91356	3	174B125   449	2160011029	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.17159	-118.53338	Plan check for Title 24 Energy only in Existing medical office space, T.I. area is in restroom and M.A. Station. Total area: 165 sq ft. B#18016-20000-23539	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21885	19041-10000-29163	9472 N SANDUSKY AVE	91331	6	198B153   187	2642017001	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.24208	-118.43287	Plan check for a PV1 7.6kw AC / 8.85 KW DC roofmounted system. Scope inlcudes (1) inverter, (29) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21886	14041-10001-04675	15053 W WYANDOTTE ST	91405	6	186B145   705	2221015028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/01/2014 12:00:00 AM	ADDRESS	34.20312	-118.4613	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2)TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(42) MODULES:  CNADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21887	18041-20001-01018	14711 W ROUND VALLEY DR	91403	4	162B149    65	2276034041	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.1442	-118.45288	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (1) load center, and (45) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21888	16041-10000-03899	1505 N EDGEMONT ST	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.09843	-118.29637	PC FOR ENERGY. T.I. FOR A MEDICAL OFFICE, 2ST FLOOR NURSE STATION  WITH NEW CASEWORK AND SINK. TOTAL AREA 1509 SQ FT,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21889	16041-10001-00682	1011 W 65TH PL	90044	8	105B197  1395	6014004019	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	33.97994	-118.29229	0 $ FEE PER SENATE BILL1222. CHANGE OF ADDRESS, DEPARTMENT ERROR, CORRECT ADD : 1011 W 65TH PL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21890	14041-20000-35079	19191 S VERMONT AVE SUITE 100	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	33.85656	-118.29099	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANNELS AND CIRCUITS. PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. TOTAL SQFT 2766. SCOPE OF WORK TO BE DONE IN SUITE 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21891	11041-10000-14430	621 S WESTERN AVE #101	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	07/18/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TENANT IN COMMERCIAL SPACE-COFFEE SHOP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21892	19041-20000-24826	10174 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.25534	-118.57964	change of use from retail to medical office.  plan check  for power and energy.building application number 19016-20000-19576	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21893	12041-10001-17068	10 W CENTURY DR	90067	5	132B161   720	4319004***	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.05654	-118.4153	"CHANGES TO THE PERMITTED SET OF PLANS. TO DIST. BOARD ""LDA"" FEEDERS AND PANEL ""K3"" WITH 24 NEW 1PH CIRCUITS . ALL CHANGES ARE MARKED AS DELTA 3ALSO, ADDED TO ELECTRICAL SPECIFICATION NOTES ""Aluminum flex and MC is allowed""Plan check for power and energy. 7680 combined sq ft (4897 indoor). Century Restaurant."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21894	18041-20000-15443	4981 N BILMOOR AVE	91356	3	171B117   489	2175010011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.16161	-118.55961	pv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21895	14041-10000-32038	6600 N TOPANGA CANYON BLVD #1004	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI to (E) 3,742 sq. ft. commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21896	18041-10000-10006	9600 N OWENSMOUTH AVE	91311	12	201B105   228	2746015008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.24438	-118.60236	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21897	14041-10000-15550	6923 S KITTYHAWK AVE	90045	11	102B173   225	4103010023	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			06/11/2014 12:00:00 AM			Reviewed by Supervisor	07/23/2014 12:00:00 AM	ADDRESS	33.97495	-118.37278	voidPC for power and energy. New 16 apartment building. Total Area 15679 sq ft(indoor+ outdoor).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21898	16041-10006-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET.  ALL CHANGES ARE CLOUDED UNDER DELTA 13. CHANGES INCLUDE REVISING CONDUCTORS SIZES FOR FIRE PUMP TO REFLECT AS BUILT CONDITIONS. REMOVING NOT ON FEEDER SCHEDULE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21899	18041-10000-29278	515 S FLOWER ST STE 1270	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLAN CHECK FOR - TI WORK ON 2668 SQ FT OF THE TOTAL FLOOR AREA; NEW WALL, POWER, LIGHTING AND FINISHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21900	16041-10001-41439	8336 S LINCOLN BLVD	90045	11	096B157   258	4113016019	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	33.96186	-118.42076	PC FOR A LOST SET OF PLANS FOR A 1009 SQFT JUICE BAR. T-24 PC ONLY. NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-41439	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21901	13041-10000-17471	4880 E HUNTINGTON DR	90032	14	142-5A233  73	5218007003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.08623	-118.17736	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING FOR A MIXED USED BUILDING. SCOPE OF WORK INCLUDES TWO BATHROOMS AND 1 HALLWAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21902	16041-10000-07501	600 W WILSHIRE BLVD 5TH FLR	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.04796	-118.25622	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING COMMERCIAL BUILDING ON THE 5TH FLOOR (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 15,912 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21903	19041-30000-50145	2049 S CENTURY PARK EAST 27TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING,CRICUITS, AND CONTROLS IN RESTROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21904	19041-20000-13652	20631 W VENTURA BLVD 202	91364	3	171B109    59	2166033039	(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.16759	-118.58307	T24 PLAN CHECK FOR EXISTING LOW RISE COMMERCIAL OFFICE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 6489SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21905	16041-10000-37550	8224 N WHITSETT AVE	91605	2	192B165   605	2308018002	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.22066	-118.40508	PV 1 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER. (16) MODULES AND (1) INVERTER. TOTAL SYSTEM SIZE 3.8.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21906	12041-10000-15263	400 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	New electrical panels and circuits for 5 new restaurants.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21907	16041-20001-01280	9255 N CORBIN AVE	91324	12	198B117   150	2761001075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM			PC Info Complete	03/17/2016 12:00:00 AM	ADDRESS	34.23837	-118.56248	03/17/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to comply with Title 24 disaggregation requirements.*****Previous Work Description*****Tenant improvement to 21,360 sq. ft. commercial office space in (E) single-story building.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21908	17041-10001-33492	1521 S HILL ST	90015	14	124-5A207 237	5134023001	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM			PC Info Complete	01/10/2018 12:00:00 AM	ADDRESS	34.03497	-118.26454	PC FOR INTERIOR REMODEL & CHANGE OF USE FROM WAREHOUSE TO CHURCH PC for T24 energy ONLY FOR  for church TI ON THE  FIRST AND SECOND FLOORS. WORK DONE IN MAIN SANCTUARY, FOYER, FELLOWSHIP HALLS AND OTHER WORSHIP SPACES.   SCOPE INCLUDES NEW LIGHTS ONLY ( NO POWER). Total area of 28652sqft.B#16016-10000-26026	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21909	15041-10001-35269	8533 N WOODLEY AVE	91343	12	192B137   107	2689025027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM			PC Approved	11/30/2015 12:00:00 AM	ADDRESS	34.22563	-118.48545	EXPEDITED FEES PER APPLICANT. PV1, ROOF MOUNTED SOLAR SYSTEM, TOTAL SIZE IS 18.36-DC. (72) MODULES AND (72) MICROINVERTERS. (72) REC SOLAR MODULES REC255PE(72) ENPHASE M215-60-2LL-S22-IG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21910	17041-20001-20268	19540 W TUBA ST	91324	12	204B117   242	2726009027	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM			PC Approved	06/30/2017 12:00:00 AM	ADDRESS	34.2565	-118.55967	pv1install roof mounted pv system sized 9.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21911	13041-10000-03664	20647 W TUBA ST	91311	12	204B109   205	2741027020	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.25641	-118.58331	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A TWO STORY HOUSE USING STANDARD PLAN. [INVERTER: FRONIUS # IG PLUS V7.5 |||| MODULES: TRINA # TSM-240 PA05] SYSTEM SIE IS 10.56 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21912	11041-10000-11093	1267 N VILLA WOODS DR	90272	11	129B129   141	4409004008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	11/09/2011 12:00:00 AM	ADDRESS	34.05208	-118.51526	MAJOR REMODEL OF (E) SFD...ADDITIONS TO (E) BEDROOM/BATH...ADDITION OF STUDY AREA...ADDITION OF GYM...EXPANSION OF FAMILY ROOM...(N) ROOF THRUGHOUT...(N) FRONT AND REAR PORCH...	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21913	11041-10000-23716	19749 W DEARBORN ST	91311	12	198B117   164	2761001055	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	02/10/2012 12:00:00 AM	ADDRESS	34.23748	-118.56389	T. I. - Office space and film editing, check power and energy.(TENANT IMPROVEMENT IN 2ND FLOOR OFFICES:  (N) INTERIOR WALLS, CEILING WORK AND FINISHES TO CREATE OFFICES.  NEW TRANSFORMER AT SECOND FLOOR AND NEW A/C UNIT AT ROOF LEVEL.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21914	19041-20000-49902	2352 N RONDA VISTA DR	90027	4	150B201  1222	5433010014	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Expired	05/14/2024 12:00:00 AM	ADDRESS	34.10451	-118.27624	PV1 PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 7.56 KW DC/7.6 KW AC. ESS SIZE IS 13.5 KWH. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER, A 5 KW BATTERY, AND A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21915	18041-10001-41558	10074 W SULLY DR	91352	2	189B181    75	2403019012	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM			Reviewed by Supervisor	11/08/2018 12:00:00 AM	ADDRESS	34.218	-118.34978	SEE APPLICATION NOTESSUPP. FOR DC CONNECTED BATTERY AS PART OF PV INSTALLATION. SCOPE INCLUDES SINGLE LGCHEM ESS (DC)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21916	11041-20000-18686	6815 N NOBLE AVE #400	91405	6	183B145   721	2220020023	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM	11/03/2011 12:00:00 AM		Permit Finaled	05/16/2012 12:00:00 AM	ADDRESS	34.19434	-118.46198	Plan check power and energy for Medical Office expansion (Surgery Center) on the 4th floor. Not reviewed for OSPHD III. Misc permit included for intercepting existing ckts to new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21917	14041-10000-05873	8120 N SEPULVEDA BLVD	91402	6	192B145   645	2654035012	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.21886	-118.46658	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING ONLY FOR LOCATION 8120 AND 8122 N SEPULVEDA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21918	17041-30002-17242	611 S GAYLEY AVE	90024	5	135B149   217	4363006021	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			10/18/2018 12:00:00 AM			PC Approved	10/18/2018 12:00:00 AM	ADDRESS	34.06777	-118.44876	[[CHANGES TO APPROVED SET. PLANCHECK ONLY FOR  DELTA 1 CHANGES. REMOVING PARTITION WALL IN UNIT 202 AND 402]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21919	12041-20000-12509	8379 W 3RD ST	90048	5	138B173   748	5511015015	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.0731	-118.37273	Initially two services (400A and 800A) supplying to existing building.   Demolition and removed of 400A service and add 800A section to 800A switchboard.  Also install new subpanels.  Plan check for power only.  (Methane Zone)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21920	14041-20000-17607	4240 N LAUREL CANYON BLVD	91604	2	165B165  1295	2368015070	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.14736	-118.39624	New 4-story (32 units) apartment bldg. over 1-level sub. garage.  New 1600A service, panels, and lighting.  Plan check for power and energy.Variance to separate fire alarm submitted on 6/30/14BUILDING PLAN CHECK TIME EXTENSION HAS BEEN FILED. REFER TO BUILDING PERMIT NUMBER 06010-10000-01527. BUILDING TO COMPLY WITH 2005 ENERGY CODE STANDARDS MINIMUM. BUILDING TO COMPLY WITH 2011 LAEC MINIMUM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21921	15041-10001-30332	1257 N EUBANK AVE	90744	15	033B209   232	7422020021	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			PC Approved	10/08/2015 12:00:00 AM	ADDRESS	33.78823	-118.25609	Expedited per customer request. (((PV 1 installation of a roof mounted solar system for a single family home. Scope of work: (1) inverter: 5 kw , (1) 125 amps load center , (20) modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21922	15041-30000-39699	16239 W NAPA ST	91343	12	192B137    37	2689024010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.2267	-118.48673	Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect new inverter and modules with existing PV system.  Total system size = 6.6 kWac (3.6 kWac new).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21923	18041-20000-33698	4048 N SAPPHIRE DR	91436	5	165B137   547	2285020043	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.14501	-118.48654	Plan check for a PV1 roof-mounted PV system. System size is 13.2 kWdc/11.4 kWac and consists of (1) inverter and (40) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21924	15041-20001-13036	16822 W GLEDHILL ST	91343	12	198B133   149	2687011009	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	34.24187	-118.49892	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21925	17041-10000-23353	17955 W VENTURA BLVD	91316	5	171B129   213	2162006004	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.16444	-118.52377	Title 24 plan check.  Interior T.I. to combine suites to create new core & shell space for new tenant.  Subpanels to remain existing with new lights and receptacles.  Lighting area = 9,817 sq. ft.       Building permit #17016-10000-18722	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21926	14041-10001-12535	2030 N KENILWORTH AVE	90039	4	147A205   328	5431018016	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.09625	-118.26809	EXPEDITD RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER WITH OPTIMIZERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21927	17041-10000-10837	10394 N SEPULVEDA BLVD	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Issued	11/09/2017 12:00:00 AM	PIN	34.25931857	-118.46630746	Plan check for power and Title-24.  First time T.I. for restaraunt space.  Two new subpanels with new lighting, equipment, and mechanical loads.  Total area = 1,713 sq. ft.     Building permit # 17016-10000-08167	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21928	12041-20000-14225	444 S FLOWER ST suite 1900	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	energy plan check suite 2000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21929	18041-10000-36927	6430 W SUNSET BLVD # 1425	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.09782	-118.32979	Design build: Energy plan check for an office TI located on the 14th floor of a high rise building. Scope includes new lighting and equipment with a total area of 3152-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21930	17041-20002-11995	400 N OAKHURST DR	90210	5	138B169   939	4335006035	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Issued	02/08/2018 12:00:00 AM	ADDRESS	34.07549	-118.39071	02/08/2018 Changes to an approved set of plans. All changes have been clouded. There has been an addition of a subpanel to the SLD. *****Previous Work Description*****PV2.  Install roof mounted grid tied PV system sized 46kW.  $0 permit fee due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21931	13041-10000-09459	19511 W ROSITA ST	91356	3	168B117   231	2175012021	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.15723	-118.55871	PV1 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 12.74 KW. STANDARD PLAN. 52 MODULES AND 1 INVERTER. [INVERTER: FRONIUS IG PLUS 10.0-1UNI] [PV MODULE: TRINA SOLAR TSM-245PC05/PA05.18].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21932	19041-10000-47838	15015 W CORONA DEL MAR	90272	11	123B129   637	4411024007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.03183	-118.52283	[EPLAN] INSTALLATION OF A NEW ESS (TESLA POWERWALL) TO AN EXISTING PV1 SYSTEM.CONNECTED TO AN EXISTING 400Amp Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21933	10041-10000-04135	12121 W PICO BLVD Unit #101	90064	11	123B149  1060	4259032028	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/08/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	ADDRESS	34.02928	-118.45083	Change of occupancy in a new retail space in Unit #101.  Two Existing Services!   Plan Check is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21934	10041-10001-06679	2106 W TEMPLE ST	90026	13	136-5A205  32	5157017028	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.01	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM			PC Info Complete	01/18/2011 12:00:00 AM	ADDRESS	34.07024	-118.26853	Modification to previously approved set of plans to show change from an overhead service to an underground service.  The building is to be supplied by a feeder, and the service is to be installed at the south east corner of the lot.  No changes to the branch circuits internal to the building.    The building is in a methane buffer zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21935	11041-10000-21543	21375 W ROSCOE BLVD	91304	3	192B105   548	2779013030	[Q]C2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	34.21998	-118.59607	TENANT IMPROVEMENT IN RETAIL SPACE - THE SALVATI0ON ARMY STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21936	17041-20000-21938	22144 W ALIZONDO DR	91364	5	165B101   176	2173015012	RA-1	South Valley	Encino - Tarzana	Encino	Yes	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.15056	-118.60691	pv1install roof mounted pv system sized 12.6kw interconnected with msp.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21937	16041-20000-24344	13055 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.18915	-118.4171	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING PARTION WALL AND REMOVE FOUR  LIGHT FIXTURES PLAN CHECK FOR ENERGY ONLY.  PLAN CHECK PER APPLICANT.  TOTAL SQUARE FOOTAGE 2100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21938	12041-10000-16146	818 N HILL ST	90012	1	135A215   289	5408032026	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM			PC Approved	07/12/2012 12:00:00 AM	ADDRESS	34.06338	-118.23906	Change of use from Retail to Cafe.  Load is less than 200A and occupancy load is 14, per applicant.  Plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21939	16041-20000-11934	1234 E 58TH ST	90011	9	108B209  1363	5104031016	MR1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM			PC Info Complete	04/06/2016 12:00:00 AM	ADDRESS	33.99007	-118.25327	Plan check for power only. Adding machinery to existing switchboard in commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21940	19041-10000-51282	1610 W LOCKNESS PL	90501	15	045B193   451	7347017038	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Issued	12/12/2019 12:00:00 AM	ADDRESS	33.81798	-118.30619	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21941	17041-20002-14641	4161 N FARMDALE AVE	91604	2	162B169    52	2368022016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	34.14418	-118.38128	Additional subpanel and disconnect.  $0 plan check fee due to State Senate Bill SB 1222. (((Plan check for the addition of a PV1 roof-mounted PV system and a Tesla AC Powerwall to an existing PV system. PV system addition size is 3 kWac and consists of (1) inverter, (8) modules, and (1) load center. Tesla AC Powerwall rating is 7 kWac.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21942	14041-20001-19246	13570 W BEAVER ST	91342	7	225B157   671	2510020012	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM			PC Approved	07/31/2014 12:00:00 AM	ADDRESS	34.31186	-118.42836	Expedite per customer request(((7.43KW PV1 roof-mounted system with (27) SolarWorld Plus SW275 modules and (1) Power One PVI-6000-OUTD transformerless inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21943	14041-10000-11086	912 E 60TH ST	90001	9	105B209    85	6007007005	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	33.98556	-118.2592	Remove HID light fixtures and replace with new fluorescent fixtures. TOTAL AREA 11400 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21944	19041-20002-18920	10509 W CAMARILLO ST pv1	91602	4	168B177   481	2420004016	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.15781	-118.35961	Plan check only, changes to approved set clouded delta 1 changes only. Change of relay location on site plan to back of house, change in existing service size on single line from 200A to 400A, and addition of fault current calculation page. No changes to sign page.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21945	19041-20000-49795	21700 W OXNARD ST 8th Floor	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.17901	-118.60179	Corridor and elevator lobby lighting. Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21946	15041-20000-14640	13330 W HUBBARD ST	91342	7	225B157   503	2512019029	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.31336	-118.42336	Plan check for PV 1 roof mounted 5.4kWac system and 24 modules and 24 micro-inverter(Enphase)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21947	17041-20001-38656	800 AAA DR DUMMY-APP	0	13	153A207    95	5437016017	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	PIN	34.11467513	-118.2612988	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.Total system size: 9.28kW ungrounded.(29) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21948	16041-10000-11127	1824 N HILLHURST AVE	90027	4	150B201  1276	5590018001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.10439	-118.28725	PC FOR POWER ONLY. SCOPE INCLUDES UPGRADING SERVICE AND SWITCHBOARD TO A 600A 120/240V 1PH 3WIRE FOR AN EXISTING COMMERCIAL BUILDING (CORE & SHELL ONLY). NO CONNECTED LOAD AT THE MOMENT, EACH TENANNT WILL SUBMIT TI INDEPENDENTLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21949	14041-20001-26374	8604 N WHITE OAK AVE	91325	12	195B129   574	2787031026	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.22691	-118.51974	FEE EXPEDITEPV1 SFD. TOTAL SYSTEM SIZE 12 KW  AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 40 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21950	15041-20001-11451	16915 W NAPA ST	91325	12	195B133   507	2689018030	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Apartment			04/17/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	PIN	34.22705349	-118.50207694	fee expeditePV2  COMMERCIAL ROOF TOP. TOTAL SYSTEM SIZE 21.4kw  AC. USING 2 CENTRAL TRANFORMED INVERTERS. total of 88 panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21951	12041-10000-12705	1600 S MAIN ST	90291	11	108B145  2052	4238021001	C2-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/04/2012 12:00:00 AM			PC Approved	06/08/2012 12:00:00 AM	ADDRESS	33.98775	-118.47066	Plan check for energy and emergency lighting. 3844 conditioned sqft. 2 story commercial building. Occupancy is less than 99 per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21952	15041-10000-29206	21700 W OXNARD ST STE 430	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Expired	02/06/2018 12:00:00 AM	ADDRESS	34.17901	-118.60179	Energy plan check for an office T.I located in the 4th floor of a high rise building; Scope includes new light, equipment and receptacles Total area is 5820-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21953	17041-20000-03163	20440 W KESWICK ST	91306	3	186B109   101	2114002005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.20957	-118.57883	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 175A. 10.4kW ungrounded system (5.2*2). (37) 315W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21954	19041-20000-42379	11958 MIRABEL WAY	91326	12	216B109   181	2701081030	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	PIN	34.29047218	-118.58190922	Plan check for PV roof mounted system, PV system size: 5.25 KW with 15 AC Modules, new sub-panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21955	16041-20009-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			07/02/2019 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	7/2/19changes to an approved set of plans.  changes to feede tags, length and voltage drop calculations.this is plan check only.changes are noted delta 16 only.((((05/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 14. Changes have been made to indicated feeder sizes, lengths, and voltage drops.))))*****Previous Work Description*****SUPPLEMENTAL PLAN CHECK ONLYCHANGES TO AN APPROVED PLAN SET. CHANGES TO APARTMENT UNIT FEEDER SCHEDULE SIZES AND CALCS. CLOUDED DELTA 11 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21956	13041-10000-09780	1734 N MAIN ST	90031	14, 9	123A207   102	5127024009		South Los Angeles				2240.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	PIN	34.03184816	-118.26351545	New fire alarm system for existing 3-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21957	18041-20000-00049	7661 W CURSON TER	90046	4	150B177   370	5551010044	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM			PC Approved	10/18/2018 12:00:00 AM	ADDRESS	34.10494	-118.3567	New SFD with 800A 240/120V 3ph-4w service.  Plan check only; electrical permit fees in building combination permit 16010-20000-02268	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21958	19041-20000-49189	2226 N AVON ST	90026	13	144B213   868	5415006057	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.09096	-118.24573	PV1 PLAN CHECK FOR NEW PV SYSTEM, SYSTEM SIZE IS 3.3 KW DC/3.15 KW AC. SCOPE OF WORK CONSISTS OF (10) PV MODULES WITH MICRO INVERTERS AND A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21959	13041-10000-36298	6539 N LEDERER AVE	91307	12	180B093   523	2036023018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.18939	-118.63922	PV1, Install 9 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US and Solaredge SE 5000A-US. (36) Modules: Trina Solar TSM-250PA05.18.(36) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21960	12041-10001-16166	642 S ALVARADO ST	90057	1	133-5A203 196	5141001035	C4-2	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.05819	-118.2755	Revision to the approved plan. Change the lighting and T24. EPC is for T24. (((((((((((((((T.I. to an existing restaurant, load is less than 400A and occupancy load is less than 99.  PLAN CHECK ONLY for Energy, with Emergency lighting.)))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21961	15041-10000-04279	8161 N LANKERSHIM BLVD	91605	6	192B169   634	2310007024	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.21911	-118.38802	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL  AREA 10316 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21962	18041-10000-15947	19531 W PARTHENIA ST	91324	12	195B117   174	2783025102	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.22836	-118.55916	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21963	14041-10002-16357	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Apartment			02/08/2016 12:00:00 AM			PC Approved	02/08/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	02/08/2015Changes to an approved set of plans. Note changes on delta 4a. PC only (((PLANCHECK FOR POWER AND ENERGY.   New 4-story, 338 unit apartment building.  10 TYPICAL UNITS. [[[FEES ARE BASED OFF APPLICANT, PLANCHECKER TO VERIFY FEES. FEES  FOR T24 (56,000SQFT), SMOKE DETECTORS (338), PANELBOARDS(SECTIONS) , AND OTHERS NOT INCLUDED DUE TO PRE CUT CHECK ]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21964	14041-20000-16369	3500 W WILSHIRE BLVD	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.06157	-118.30077	plan check for title 24 energy and emergency lighting only.  existing commercial two floor building with new lighting on both floors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21965	15041-10000-11810	450 S WESTERN AVE #104	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	PC FOR ENERGY ONLY.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  TOTAL AREA 503 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21966	12041-10000-10470	249 S BRISTOL AVE	90049	11	129B137    70	4406021016	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2012 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.05329	-118.48773	Plan check for auxiliary service 600A  pool house and two new subpanels. Equipment are on seperate permit or existing.  Main house service approved under#12041-10000-01611	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21967	12041-10000-19048	14006 W RIVERSIDE DR	91423	4	168B153   929	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	08/14/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	"PLAN CHECK T24 ENERGY FOR NEW KITCHEN KIOSK (""HOT DOG ON A STICK"" SPACE #9270) AND STORAGE (SPACE SM#248) IN AN ENCLOSED WESTFIELD SHOPPING MALL."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21968	16041-20000-31947	13357 W REEDLEY ST	91402	6	192B157   194	2627027022	(T)R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.22503	-118.42432	Plan check for installation of roof-mounted solar array. Interconnect with 200A MSP.5kW ungrounded system. (20) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21969	17041-10000-05826	1623 N ALLESANDRO ST	90026	13	142-5A207 214	5423010007	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.08472	-118.26079	PC for Outdoor title 24. Removing HID fixtures and replacing them with new LED ones. Area: 27,200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21970	15041-10000-43760	3550 W 6TH ST	90005	10	135B197  1037	5502031014	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.06341	-118.30006	New fire alarm system to an apartment building (5 stories). (1) Fire alarm panel, (4) Control panels, (1) communication panel, (353) Fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21971	12041-20000-27814	6100 N TOPANGA CANYON BLVD #2230	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	12/04/2012 12:00:00 AM	ADDRESS	34.18131	-118.60555	Plan check for energy. 270 sqft. cat adoption center.Express permit for a dryer and water heater.Orignial permit on 12041-20000-26696INSTALL NEW AND RELOCATE OUTLETS, ADD 1 EXIT SIGN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21972	10041-10000-01523	11075 W FOOTHILL BLVD	91342	2	210B173     7	2529023901	OS-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00, 1041.04	Electrical	Electrical	Public Safety Only			01/28/2010 12:00:00 AM	01/28/2010 12:00:00 AM		Permit Finaled	04/07/2010 12:00:00 AM	ADDRESS	34.27467	-118.37154	Upgrade the fire alarm system for a recreational center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21973	17041-20000-20547	18438 W BURBANK BLVD TEMP	91356	3	174B125   437	2160010036	[Q]C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	PIN	34.17149566	-118.53428225	Plan check for power only. TEMP power for construction trailers. Installing service, main panel, and pole mounted disconnects. Feeders are run overhead. 600A 277/480V 3ph 4w.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21974	14041-20000-22806	20756 W SATICOY ST	91306	3	186B109   253	2113011009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Expired	09/22/2016 12:00:00 AM	ADDRESS	34.20817	-118.58587	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. USING STANDARDS PLAN. TOTAL OF 25 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21975	13041-10000-12776	5711 W CENTURY BLVD GROUND	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	ADDRESS	33.94573	-118.38128	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ON A HIGH RISE. BALLROOMS ON GROUND FLOOR. PLAN CHECK ONLY. PERMIT TO BE PULLED UNDER APPLICATION 13041-10001-12776.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21976	14041-20000-25127	13274 W PIERCE ST	91331	7	207B157  1092	2620025032	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.26094	-118.42172	INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(16) SUNPOWER SPR-327NE MODULES(1) SOLAR EDGE TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21977	16041-30001-15019	7485 W 80TH ST	90045	11	099B157   609	4114036029	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM			PC Approved	09/23/2016 12:00:00 AM	ADDRESS	33.96386	-118.4283	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 5.2kWac with 21 modules and 21 microinveteres SFD}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21978	16041-10000-44946	1549 W WASHINGTON BLVD	90007	1	126B197   661	5056021003	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.04018	-118.29033	PC for energy only; Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 14,225.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21979	13041-10000-00012	630 W 28TH ST	90007	8	121-5A203 146	5123014401	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			01/02/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.02634	-118.27859	New Building 9 Units 3 story over basement. Methane Zone. Full plan check for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21980	19041-10000-12266	4208 E HUNTINGTON DR SOUTH	90032	14	139-5A229  47	5214001002	[Q]A1-1XLD, [Q]C2-1VL, [Q]RE20-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	08/02/2022 12:00:00 AM	ADDRESS	34.07889	-118.19263	AFFORDABLE HOUSING: PC FOR POWER AND ENERGY FOR A PROPOSED OF 4-STORY APARTMENT BUILDING ,SERVICE RATED AT 2500A 120/208. TOTAL AFFECTED AREA 45812 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21981	15041-20000-22580	5846 N LE SAGE AVE	91367	3	174B093    44	2041026007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Expired	08/10/2017 12:00:00 AM	ADDRESS	34.17678	-118.64164	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21982	14041-10001-29315	1619 N GOWER ST	90028	13	148-5A189 227	5546027013	C4-2D	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	34.1004	-118.32258	Change to approved set by modifying the lighting fixture on the floor plan, all lighting load also being updated.(((Full plan check for power and energy new car retail faclity including office building and car wash.  Office building 1532 sq ft car wash building  874 sq ft, parking lot 13426 sq ft. Service size 400 amps.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21983	18041-20001-49017	10960 W WILSHIRE BLVD 100	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.058	-118.44597	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE TOTAL WITH 4562 SQFT. INSPECTION FEE UNDER MASTER PLAN 18041-90000-49017	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21984	12041-10000-23585	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Expired	03/04/2015 12:00:00 AM	ADDRESS	34.0965	-118.30717	Modify to the existing fire alarm system in LAB, BUD-STONE, and KONA buildings.  Replace F.A control panel and remote power supplies.  New driver cards install to the existing devices for FACP compatibility.  Replace some F.A. devices in LAB building.  All other existing devices to be remained.   All existing conductors to be remained.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21985	10041-20001-23571	7929 N RUFFNER AVE	91406										Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM			PC Approved	03/30/2011 12:00:00 AM	ADDRESS	34.21441	-118.49704	revise enegy calculations	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21986	19041-10000-41366	9189 N DE GARMO AVE Phase 2	91352	6	198B173   125	2408034042	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	02/04/2022 12:00:00 AM	ADDRESS	34.23604	-118.37603	New one story metal warehouse structure to enclose an existing material recovery facility and transfer station operation (recycling facility).  New equipment added to (2) (E) 277/480V services.  Plan check for power and energy  Phase 2 of multi-phase project.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
21987	16041-10000-03664	100 WORLD WAY SPACE 160	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR ENERGY. T.I. TERMINAL 1 OF LAX. EXISTING RETAIL STORE. ORIGINAL ELECTRICAL WAS FINALED ON PERMIT #15041-10000-29132. ADDING NEW LIGHT FIXTURES.  TOTAL AREA 745 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21988	14041-20001-15624	7936 N DE SOTO AVE	91304	3	189B109   493	2108029004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.21479	-118.5883	Fee for expedite only.*****New roof mounted PV system with 300W Optimizers, and two 3.8KW transformerless inverters.  Total system size 8.67KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21989	19041-10000-49195	2123 N HILLHURST AVE	90027	4	150B197   125	5590003037	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.11056	-118.2876	Energy plan check only Interior non-struc'l T.I. to (e) restaurant. affected area 2910SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21990	13041-10000-11271	932 N ALFRED ST	90069	5	144B173   262	5529002040	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			05/01/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.08806	-118.37515	pc for power and energy. 4 stories. not methane. CONSTRUCT A 4-STORY,  (8 UNIT) APARTMENT BUILDING OVER A SUBTERRANEAN GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21991	18041-10000-44823	14311 W VENTURA BLVD	91423	4	165B153   255	2265019001	(T)(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	34.15039	-118.44453	NEW 2-STORY RETAIL & RESTAURANT OVER 2 LEVELS OF SUBTERRANEAN PARKING. SCOPE INCLUDES NEW 2500A SERVICE, SWITCHBOARDS, PANELS AND EQUIPMENT. TOTAL EFFECTED AREA IS 159,889 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
21992	18041-10000-48190	8771 N TYRONE AVE	91402	6	195B149   508	2639003012	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.22932	-118.44822	NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (17) MODULES, (17) OPTIMIZERS AND (1) 3.8 KW INVERTER.TOTAL SYSTEM SIZE IS 5.610KWDC AND 3.8KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
21993	10041-30000-12615	22 E WINDWARD AVE	90291	11	106-5A143  57	4226009018	C2-1-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	10/25/2010 12:00:00 AM	ADDRESS	33.987	-118.47308	T.I FOR RESTAURANT. PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21994	16041-20001-14086	3921 N LAUREL CANYON BLVD	91604	2	162B165   437	2369013019	R1-1-RFA-RIO, R1-1VL-RFA-RIO, [Q]RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.14179	-118.39477	05/16/2016 Changes to an approved set of plans. Changes have been made to expand the scope of work. All lighting changes have been reflected onto the Title 24 Compliance Forms. Note: Building permit has been pulled under 16016-10000-01266*****Previous Work Description*****Plan check for energy only. CHANGE OF USE OF PORTION OF DORMITORY TO EDUCATIONAL OFFICES AND CLASSROOMS. First floor TI. New lighting (incl. emergency) and receptacles.5,510sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21995	19041-10000-02197	12200 W OLYMPIC BLVD	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.03195	-118.45506	PC ONLY!Energy plan check for an office space T.I . Scope include new lighting and equipment with a total area of  2993sq-ftDESIGN CHANGE UNDER NEW APPLICATION. UNDER 19041-10000-21549	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21996	17041-20000-21088	10047 N RUDNICK AVE	91311	12	204B101   497	2745007061	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.25307	-118.61281	Plan check for solar pv system, roof-mounted on SFD.2.88kW ungrounded system.(12) EnPhase M250 microinverters.(12) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
21997	10041-10000-20857	520 S VIRGIL AVE Suite #301	90020	4	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	12/30/2010 12:00:00 AM	ADDRESS	34.06457	-118.28687	TI IN AN EXISTING COMMERICIAL AREA IN SUITE # 301. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21998	12041-20001-27401	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	PIN	34.03245819	-118.45766562	Relocation of distribution equipment to inside 12333 W. Olympic. Refer to 12041-10000-27401 for core and shell. Build out on 13041-20000-06945.INSTALL A NEW 277/480V, 3ph, 4W, 5,000 AMP SERVICE FOR TWO NEW BUILDINGS (PARKING STRUCTURE AND BUILDING #4).  THERE ARE NO CONNECTED LOAD AT THIS TIME. ALL FUTURE TI's REQUIRE COMPLETE ELECTRICAL PLAN CHECK AND PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
21999	19041-20000-48406	8705 N OAKDALE AVE	91324	12	195B113   515	2782012058	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	PIN	34.22879574	-118.56698187	PV1.  Install 10.31 kW AC CEC roof mounted PV system.  (36) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22000	15041-10005-16378	940 S FIGUEROA ST basement-5th floor	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Approved	04/12/2018 12:00:00 AM	ADDRESS	34.04538	-118.26335	[[[4//11/18 CHANGES TO APPROVED SET. DELTA 5 CHANGES. PLANCHECK ONLY.  INSTALLATION OF A VFD TO CONTROL (4) MOTORS. ]]]]09/27/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the fire pump wiring and fused disconnects.09/12/2016 Changes to an approved set of plans. Changes include the relocation of power equipment to a new electrical room. All changes have been clouded and marked as Delta 4. Note: Building application for the new electrical room is under 14016-10003-1352805/04/2016 Changes to an approved set of plans. Changes have been made to provide power to electrical equipment. Transformer has been added to change voltage class to power said equipment.02/18/2016  CHANGES TO APPROVED SET. ADDITION OF FIREPUMP AND JOCKEY PUMP TO THE SYSTEM REQUIRED BY MECHANIAL*****Previous Work Description*****New service upgrade and distribution equipment for assembly occupancy. new design. This is core and shell clear out of existing building. TI package will be submitted at a later date. per building submittal, PC is accordance to 2008 building efficiency standards.project is in methane buffer zone. NOT A HIGHRISE PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22001	16041-10000-45666	1002 W D ST BLDG 3	90744	15	027B201   420	7417010946	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM				PC for new fire alarm panel with 35 devices and 2 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22002	11041-10000-13733	1545 W WILSHIRE BLVD 1st fl	90017	1	132A205   208	5142027025	CW	Central	Westlake			2091.02	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.05543	-118.26977	new panelboard and circuits in renovating offices on the  1st  flplan check is for title24 and 1 ea emergency ckt ; permit fee is in Inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22003	16041-20001-20063	8884 N KEWEN AVE	91352	6	195B165   366	2631030005	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM			PC Approved	06/20/2016 12:00:00 AM	ADDRESS	34.23069	-118.39346	EXPEDITEPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22004	19041-20000-50280	110 E 9TH ST 5th Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	04/10/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TI to commercial tenant spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22005	13041-10001-30839	17523 W LANARK ST	91325	12	189B129    85	2201006012	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.21809	-118.51508	Expedited RSES plan check per applicant request.PV1, Install 6.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 27 modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22006	10041-10000-06588	1149 W 190TH ST	90248	15	060B197   546	7351028018	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	07/06/2010 12:00:00 AM	ADDRESS	33.85848	-118.296	Remodel for medical office building.  Inspector to verify the rating and Listing of the  X-Ray machines and the UL Listing of the new tap section.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22007	16041-10000-20562	555 W 5TH ST 27TH FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	ADDRESS	34.05016	-118.25369	T-24, PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING ONLY TO  A VIDEO CONFERENCE ROOM.  TOTAL SQ. FT. 673.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22008	16041-20001-29494	14721 W CALIFA ST	91411	4	177A149   147	2244009026	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.1777	-118.45431	12/16/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta A. Changes have been made to breaker ratings.*****Previous Work Description*****1200 A 480Y/277V service upgrade to (E) single-story commercial building without current tenant.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22009	11041-20000-16675	933 N LA BREA AVE 2ND FLR	90046	5	144B181   679	5531016022	MR1-1	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	08/08/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	PIN	34.08817379	-118.34466503	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT 2ND FLOOR. PERMIT FOR ELECTRICAL WORK ON EXISTING CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22010	15041-10000-12262	9043 N LURLINE AVE Bldg 6	91311	3	198B109   193	2780001058	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Issued	07/06/2015 12:00:00 AM	ADDRESS	34.23512	-118.58442	TI TO AN EXISTING OFFICE/WAREHOUSE TWO STORY COMMERCIAL BUILDING.  FIRST TIME TENENT PLAN CHECK FOR POWER AND ENERGY.  EXISTING SERVICE/SWITCHGEAR, ADDING NEW PANELS AND CIRCUITS.  TOTAL SQUARE FOOTAGE 28000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22011	17041-10000-31269	333 S HOPE ST 20TH FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC for T24 only for office TI of entire 20th floor. PC for new circuits, receptacles, lights and equipment.Installed load under 400A. Total area of 9808 sqft. Building# 17016-10000-25212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22012	18041-10000-00227	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Closed	03/07/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	"CHANGES TO AN APPROVED SET OF PLANS FOR LAX TERMINAL 2.  ALL CHANGES ARE CLOUDED UNDER DELTA ""A"", ""0"", ""1"",  ""02"", ""03"", ""RFI"", ""C"", ""17"",  & ""18"".  CHANGES INCLUDE NEW MOTORS, NEW PANELBOARDS, AND TWO  NEW 800A DISTRIBUTION BOARDS. REVISING SINGLE LINE DIAGRAM, POWER FLOOR PLANS, PANEL SCHEDULES, LOAD CALCULATIONS, AND EMERGENCY PHOTOMETRIC PLANS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22013	16041-10000-40603	767 S ALAMEDA ST #231	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	Plan check for Title 24 only in existing space T.I. Office. Total area: 4,857 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22014	11041-10000-02574	6740 W HOLLYWOOD BLVD	90028	13	148-5A185 149	5547012016	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Public Safety Only			02/09/2011 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.10139	-118.33752	NEW FIRE WARNING SYSTEM FOR EXISTING 2-STORIES  COMMERCIAL BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22015	14041-20000-01906	6343 N BABCOCK AVE	91606	2	180B161  1178	2332014006	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.18601	-118.40651	New rooftop mounted PV system for an existing single family dwelling.  System is UNGROUNDED and uses DC/DC converters at each photovoltaic panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22016	18041-10000-16895	10624 N LAS LUNITAS AVE	91042	7	207B197  1026	2566010020	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.262	-118.2912	New PV roof mounted system using central inverters and power optimizers. (19) Pv modules, (19) optimizers and (1) 5kw central inverter. Total system size is 5KWAC and 5.7KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22017	17041-10000-45896	200 S MAIN ST	90012	14	130-5A213 115	5161026023	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Closed	06/19/2019 12:00:00 AM	ADDRESS	34.05073	-118.24453	PC FOR POWER FOR A NEW EV CHARGING STATION IN EXISTING PARKING STRUCTRE. SCOPE INCLUDES TAPPING EXISTING SERVICE AND INSTALLING NEW DEDICATED EV DIST. BOARD(4000A 480/277V) AND  PANELS INCLUDING EV EQUIPMENT. PROJECT COVERS INSTALLATION ON FLOORS 1-4 .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22018	12041-10000-03515	1625 W 190TH ST	90248	15	060B193   387	7351001024	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	02/15/2012 12:00:00 AM		Permit Finaled	03/22/2012 12:00:00 AM	ADDRESS	33.85851	-118.30846	New fire alarm system for a comercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22019	14041-10001-06158	2327 S GLYNDON AVE	90291	11	111B149  1380	4242031011	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	33.99648	-118.44991	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY SINGLE FAMILY DWELLING, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(23) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22020	19041-30000-47634	8141 S GULANA AVE	90293	11	096B153     1	4115021800		West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	05/06/2020 12:00:00 AM		Permit Finaled	11/18/2020 12:00:00 AM	ADDRESS	33.96169	-118.43753	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 290 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22021	19041-20000-43789	9135 N TAMPA AVE Str# 1347	91324	12	198B117   181	2761037006	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	10/07/2020 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.23623	-118.55378	FULL PC FOR A NEW 800A DISTRIBUTION PANEL CONNECTED TO AN EXISTING SERVICE OF 4000A (480/277 3P,4W). THE NEW 800 DISTRIBUTION PANEL, FEEDS VARIOUS SUBPANELS AND VARIOUS POWER TRANSFOMERS. TOTAL AFFECTED AREA IS 48,818 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22022	19041-20000-32215	12753 W MULHOLLAND DR	90210	2	159B161   295	2385022014	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM			Reviewed by Supervisor	09/27/2019 12:00:00 AM	ADDRESS	34.12992	-118.41066	Plan check for PV roof mounted system, PV system size: 22.1KW DC, 20.22KW AC with 67 PV Modules and 2 inverters(11.4KW) connected to 400A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22023	18041-10003-08362	10314 N WOODWARD AVE	91040	7	204B193   603	2559008020	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.25645	-118.30689	PC for new 7.5 KW + Tesla powerwall and 200A load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22024	18041-20000-08477	4917 N SUNNYSLOPE AVE	91423	4	168B157   159	2359015022	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.16005	-118.427	addition of (1) tesla power wall to an exisiting pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22025	13041-10002-36081	928 S BROADWAY	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			08/24/2017 12:00:00 AM			PC Info Complete	10/03/2017 12:00:00 AM	ADDRESS	34.04154	-118.25658	PC for power for changes to approved set under delta 5. Changes include tapping a new 800A feeder to feed two panels P4B and P4A, adding two new panels C1 and C2 for HVAC equipment, upsizing firepum from 125 to 150HP and reconnection of panels P4D and P4C. Added 1200 section to supply electric vehicle chargers	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
22026	12041-10000-06739	3756 W AVENUE 40 #N,P,Q,R	90065	1	154-5A217  22	5472001070	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM			PC Approved	04/04/2012 12:00:00 AM	ADDRESS	34.1195	-118.22799	T.I. to an existing grocery store.  292A of load per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22027	14041-10000-09900	14848 W COHASSET ST	91405	6	186B149   342	2218010002	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.20653	-118.45696	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22028	10041-20000-25693	11100 W SANTA MONICA BLVD 16th Floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Closed	04/30/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	T.I. to a high rise building partial of 16th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22029	11041-10000-21286	11976 W CULVER BLVD 1-78	90230	11	108B161   154	4218007025	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	33.99512	-118.4173	Install new addressable fire alarm system with 257 devices and 4 control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22030	10041-10000-02339	6453 N VAN NUYS BLVD	91411	6	180B149   701	2236016005	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02, 1281.00	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	02/10/2010 12:00:00 AM		Permit Finaled	04/06/2010 12:00:00 AM	PIN	34.18780077	-118.44914857	TI - existing retail (space used as a pharmacy) - Permit is for new ckts only.  P/C is for Energy and Emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22031	18041-10000-14576	10050 W RIVERSIDE DR	91602	4	165B181    65	2424010040	[Q]C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.15198	-118.3498	PC FOR BANK TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 17658  SQ.FT 97 UNITS INDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22032	15041-10000-01354	200 WORLD WAY TERM 2-ARRI LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 ARRIVAL LEV 1  SPACE 283PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22033	19041-10000-33709	12025 N WOOD RANCH ROAD	91344	12	216B129   130	2601068017	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.29008	-118.52373	***$0 Permit Fee Due to AB1414*** PV1 NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 12.95 KWdc/11.4 KWac. SCOPE OF WORK IS 35 MODULES (LG370Q1C-V5) WITH OPTIMZERS (SE P370) LEADING TO TWO CENTRAL INVERTERS (SE3800H-US AND SE7600A-US) WITH A BATTERY BACKUP (LG CHEM RESU 10H).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22034	13041-10000-13098	19913 W INGOMAR ST	91306	3, 4	189B113   998	2106004060	C2-1, R1-1	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Wilshire	Greater Wilshire, Winnetka		1341.01, 2110.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.21205	-118.56711	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A STANDARD PLAN. SYSTEM SIZE IS 11.76 KW. USING 48 MODULES IN 4 STRINGS. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: FROUNIUS # IG PLUS V 10.0]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22035	15041-20000-02800	12473 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.97916	-118.41034	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22036	11041-10000-00222	324 W 7TH ST	90014	14	127-5A209  13	5144014043	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	01/05/2011 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.04546	-118.25432	Install a new Fire Alarm System on the 1st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22037	15041-10000-31131	333 S HOPE ST 19TH FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (BANK OF AMERICA). SCOPE INCLUDES NEW LIGHTING ON THE 19TH FLOOR OFFICE SPACE. TOTAL AREA IS 4220 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22038	17041-10000-20250	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	33.79173	-118.23549	REPLACE 2400V MOTOR CONTROLLER AND REFEED 2 MOTORS. PC FOR POWER SYSTEM ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22039	16041-10000-15877	11630 W BARRINGTON CT	90049	11	135B145   579	4401006012	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.06508	-118.46917	PC FOR TI. RETAIL. NEW LIGHTING. T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22040	17041-10000-06056	11800 W SANTA MONICA BLVD 1-147	90025	11	126B149   466	4262005047	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.0426	-118.45824	FULL PC FOR POWER AND ENERGY. TI FOR A NEW TARGET RETAIL STORE. SCOPE INCLUDES A NEW 800A  120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 30006 SQ/ FT. B#17016-30000-04144	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22041	16041-10000-41874	6255 W SUNSET BLVD Suite 2210	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Issued	11/29/2016 12:00:00 AM	ADDRESS	34.09815	-118.32564	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE (SUITE 2210). TOTAL AFFECTED AREA IS 1594 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22042	16041-20001-39161	13355 W CANTARA ST	91402	6	192B157   783	2301001032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.21996	-118.42454	expedite per applicantpv1install roof mounted pv system sized 14kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22043	11041-10000-07563	1700 E CESAR E CHAVEZ AVE Ste 1400	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2035.00	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.05093	-118.21753	T.I.  NEW TENANT WITHIN THE WHITE MEMORIAL MEDICAL OFFICE BUILDING.  BEING TURNED INTO AN ORTHOPEDICS MEDICAL OFFICE SUITE 1400.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22044	18041-10001-29758	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.10311	-118.31242	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING KITCHEN WITHIN EXISTING BUILDING - TOTAL AFFECTED AREA = 1000 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22045	14041-20001-35686	4421 N BELLINGHAM AVE	91604	2	165B165   304	2364003070	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM			PC Approved	01/05/2015 12:00:00 AM	ADDRESS	34.15105	-118.39882	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. ROOF MOUNTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22046	18041-10000-32783	7131 N VAN NUYS BLVD	91405	6	183B149   108	2219008011	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.20021	-118.44901	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22047	18041-10000-42359	9423 N RUFFNER AVE	91343	12	198B137   122	2687014024	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.24229	-118.49724	Plan checkf for a PV1 7.6KW AC / 9.45KW DC roofmounted system with (1) 7.6KW inverter, (30) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22048	19041-20003-00983	7432 N RESEDA BLVD	91335	3	186B125   557	2119017054	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Approved	09/06/2019 12:00:00 AM	ADDRESS	34.20567	-118.53585	9/6/19 changes to approved set delta one only. Relocation of inverters to the roof. 4/23/2019changes to an approved set of plans.  changes to reconfigure strings and meet site conditions.  this is plan check only.((((permit fee $0.00 by senate bill no.1222Plan check for a PV2 roof-mounted PV system. System size is 128.7 kWdc/112.4 kWac and consists of (4) inverters, (390) modules, and (1) load center.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22049	19041-20000-28051	16331 W CELINDA PL	91436	5	165B137   208	2284017014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.14957	-118.48939	Installation of 27 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22050	15041-20000-25023	7224 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	33.97406	-118.2913	TI to existing commerical building (liquir store). Plan check for energy only. Adding new lighting including emergency. Total sqft. 4,125.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22051	15041-20000-26320	550 S HOPE ST Suite 2100	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	Title 24 plan check only.  Total area = 1,155 sq. ft.  T.I. to existing commercial highrise space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22052	12041-10000-23303	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.10686	-118.33085	TI in a retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22053	15041-20000-02918	5022 E YORK BLVD	90042	1	156A225   320	5477001006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.1212	-118.20615	PLANCHECK FOR T24 ENERGY ONLY. RESTAURANT.   NOT A FIRST TIME TENANT PER APPLICANT. 2090 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22054	18041-30000-41474	633 W 5TH ST 16TH FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	PLAN CHECK FOR T24 ONLY, FULL FLOOR INTERIOR OFFICE TI. ON THE 16TH FLOOR. TOTAL AREA: 20,870 SQ.FT(B# 18016-10000-34017)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22055	19041-30000-15987	633 W 5TH ST Suite 5850	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Issued	05/02/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project site is an existing suite on the 58th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,374 sq. ft.Note: Building permit has been issued under 19016-10000-07906	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22056	13041-10000-29521	4929 N HASKELL AVE	91436	5	168B141    95	2261006061	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Expired	12/08/2015 12:00:00 AM	ADDRESS	34.16029	-118.47511	PV1.  Install 7.25 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: Aurora PVI-6000-OUTD-US.  29 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22057	19041-10000-27511	11244 N LAUREL CANYON BLVD	91340	7	210B149   255	2613022026	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.27455	-118.44864	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22058	16041-20000-17368	2149 E SACRAMENTO ST	90021	14	123A217   222	5166005008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	05/17/2016 12:00:00 AM	ADDRESS	34.0307	-118.22825	Plan check Title 24 only for T.I.  in existing office space. Total indoor lighting area: 5,679 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22059	14041-10000-19266	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	33.94955	-118.38342	NEW FEEDER FROM 1600A CB ON THE SWBD; FEEDER SUPPLIES NEW 1600A DIST BD WHICH SERVES NEW 40HP AIR DRYERS AND COMPRESSORS; NEW DISC SWITCHES FOR EXISTING COMPRESSORS. Submittal 2: added disconnects and new feeders. 75, 75 and 150 HP (7/17/14)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22060	16041-20000-43171	515 S FLOWER ST 21st Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for energy only. TI to office on 21st floor of high rise building. New lighting (incl. emergency) and receptacles. 21,116sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22061	17041-10000-19132	2423 E 1ST ST	90033	14	127-5A223 177	5180002013	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.04348	-118.20886	FULL PLAN CHECK FOR 29 UNIT APARTMENT. PROJECT CONSIST OF 1600A SERVICE AT 208V IN A METHANE ZONE. ALL ELECTRICAL EQUIPMENT IS WITHIN THE BUILDING NOT EXPOSEED TO HAZARDOUS AREA. TOTAL AFFECTED AREA = 18,106 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22062	16041-10001-22628	6600 N TOPANGA CANYON BLVD # 2036	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM			PC Approved	09/27/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Changes to approved set of plans. Changes include adding motion sensors, exit signs, and unit equipment on the lighting floor plan. All changes are clouded under delta 1. Changes to reflect what is on the field.Note: Application is under PCIS#16041-10000-22628 ((((((   PC FOR ENERGY ONLY. tenant improvement of existing retail space (#2036) TOTAL ARAE 2657 SQ FT.B # 16016-30000-12092 ))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22063	12041-10003-28962	905 E 2ND ST	90012	14	129A215   180	5163004006	(T)(Q)C2-2D	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			05/19/2016 12:00:00 AM			PC Approved	05/19/2016 12:00:00 AM	ADDRESS	34.04729	-118.23499	Changes to approved set per field installation under Delta-2: changed 80 KVA inverter to 100 KVA inverter, Changed wire matl' for MA3 meter bank from Alum. to Cu.((ADDITIONAL FEE PER INSPECTION REQUEST FOR (123) BOOSTER FAN CONTROLLER UNITS))(((Changes to approved set.  Removal of drip loop sections, rerouting of main service feeder and distribution board for under slab building, and other changes to distribution equipment and system.  Initial revised plan set submitted without numbered delta changes - applicant has agreed to provide revised plan set with delta changes in addition to letter enumerating changes to approved set (included in submittal).  (((5-stories mixed use building over 2 levels basement; 320-Apts;)))    )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22064	18041-20000-15505	5555 W MELROSE AVE STAGE 16	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Replacement of 750 kVA 2.4kV-208V unit substation and associated downstream distribution in studio facilities.  Replacement of cloth insulation feeder and branch circuit wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22065	14041-20001-11498	11601 W WILSHIRE BLVD SUITE 500	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM			PC Approved	09/30/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	Supplemental plan check for modifications to approved set. Replace 2x2s with downlights in hallway. Replace 2x2s in conference room with new linear light fixture 1x4s. Two new pendant lights in business lounge. Delta 3 changes.[pc for t24 energy only. existing office remodel. new lighting. WORK DONE IN SUITE 500]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22066	17041-10001-28565	1246 W 30TH ST	90007	9	120B197   346	5039001065	(Q)R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.02732	-118.29025	Supplemental PC for change in scope of work. All existing fire alarm devices labeled (E) to be reconnected to new fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22067	18041-10001-12970	1541 N VIEWSITE DR	90069	4	147B169   443	5558004023	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM			PC Approved	06/11/2018 12:00:00 AM	ADDRESS	34.09959	-118.38291	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.4KWac.(38)MODULES-SOLARCITY #SC325(2)INVERTERS-DELTA SOLIVIA 5.2 TL(1) 125A LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22068	12041-20000-26805	2844 W ROWENA AVE Lot 6	90039	4	151-5A207 173	5434033010		East Los Angeles			YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.10762	-118.26616	Enphase system on roof of single family dwelling. ADDRESS IS ALSO  2836 Buzz Ct.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22069	15041-10000-35936	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 167	5544025035	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			10/27/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.10155	-118.31097	New fire alarm system to a new apartment complex. (1) FA panel  (1) Communication panel. (18) power supplies (970) FA devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22070	18041-10000-21816	2602 S ORANGE DR	90016	10	123B177   999	5049014009	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Apartment			06/12/2018 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	09/06/2021 12:00:00 AM	ADDRESS	34.03224	-118.3533	FULL PC for power and energy for a new 3-story 25 unit (affordable housing) apartment building over a retail and parking level garage. Installation of a 2000A 120/208V 3 Phase 4 wire Service/ distribution board, new panelboards, new lights and receptacles. Total affected area is 19,171 SQ. FT. B#18010-10000-01056	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22071	16041-10000-40631	767 S ALAMEDA ST #232	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE FOR SUITE #232. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 12400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22072	16041-20000-17366	2159 E SACRAMENTO ST	90021	14	123A217   222	5166005008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	05/17/2016 12:00:00 AM	ADDRESS	34.0307	-118.22801	Plan check Title 24 only for T.I.  in existing office space. Total indoor lighting area: 10,617 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22073	14041-10000-31385	4400 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Expired	02/27/2017 12:00:00 AM	ADDRESS	34.09662	-118.28529	Title 24 plan check only.  Total area = 3,202 sq. ft.TI to existing 3 story commercial office space.  New recepticles installed in basement level, level 1, and level 2.  New lighitng installed on level 1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22074	14041-20000-31388	20832 W VALERIO ST #6	91306	3	186B109  1048	2113013***	(Q)RD2-1, (Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Issued	11/25/2014 12:00:00 AM	ADDRESS	34.20456	-118.58754	PV2Install a roof-mounted solar array on a Condominium. Interconnect with 200A MSP.System size: 6kW. Ungrounded system. Using 300W power optimizers.31 255W pv modules across 2 strings (13+18).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22075	14041-20000-35036	11415 N RUGGIERO AVE	91342	7	213B173   387	2529020027	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.27724	-118.36694	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 15.8KW INTERCONNECTED WITH MSP LINE SIDE TAP.(65) LG280S1C-B3 MODULES(3) SOLAR EDGE INVERTERS(65) POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22076	16041-10002-24464	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Closed	05/01/2019 12:00:00 AM	ADDRESS	34.09818	-118.35187	PC for changes to approved set. Changes include addition of two new panels, new circuits and lighting changes. All changes clouded UNDER DELTA 10-12.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22077	14041-20000-23461	8857 N LARAMIE AVE	91306	3	195B113    94	2781032031	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.23153	-118.57343	PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING TRANSFORMERLESS INVERTER USING STANDARD PLAN. USING POWER OPTIMIZERS. USING 2 CENTRAL INVERTERS.FIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22078	15041-20001-14565	12751 W MILLENNIUM Building B	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	10/23/2015 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes include the installation of (1) new panel and the relocation of lighting circuits to the new panel.*****Previous Work Description*****Title 24. Plan check for energy for energy only. Existing retail building. Adding new lighting including emergency. Total sqft. 2,700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22079	17041-10000-43322	915 W WILSHIRE BLVD STE 1650	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Issued	12/27/2017 12:00:00 AM	ADDRESS	34.05069	-118.2599	Energy plan check for the 16th floor office T.I . Scope inlcudes new lighting and equipment. Total area is 7,602 SQ FT.PARTIAL PERMIT FOR THE SCOPE PULLED UNDER 17041-90000-45446 (47 120V CIRCUITS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22080	14041-20001-25864	7625 N VAN NUYS BLVD	91405	6	186B149   109	2210031001	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.20911	-118.44904	PC FOR CHANGES TO APPROVED SET OF PLANS. ALL CHAGES CLOUDED DELTA 2 REVISION. CHANGE TO AC UNITS FROM 3PHASE TO 1PHASE. updated load calc as well	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22081	11041-10001-27345	6600 N TOPANGA CANYON BLVD #2102	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for revision to approved T-24 lighting compliance and emergency. Papaya Clothing Space #2102	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22082	14041-10000-09875	444 N LARCHMONT BLVD	90004	4	141B189  1186	5523021037	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.07874	-118.32347	NEW FIRE ALARM SYSTEM FOR ELEVATOR RECALL. 4 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22083	15041-10000-05368	10014 N WEALTHA AVE	91352	7	204B173   402	2538028014	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.25219	-118.3734	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200S MSP located on a detached garage.System size: 4kW. Ungrounded system. (16) 270W pv modules across two strings (8+8).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22084	15041-20000-39036	23340 W AVENUE SAN LUIS	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Expired	12/21/2017 12:00:00 AM	ADDRESS	34.15957	-118.63536	Plan check for energy only. TI to existing restaurant (McDonald's). New lighting (incl. emergency). Building application was submitted prior to July 1st, 2014, so Title 24 compliance is to  the 2008 code. 1,329sqft indoor, 10,671sqft outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22085	16041-20001-19810	540 S CATALINA ST	90020	10	135B197   936	5502022019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.06411	-118.29524	PV2.  Install 58.48 kW roof mounted PV system.  (2) separate PV systems on building occupying same rooftop.  System 2 of 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22086	18041-10000-31962	12801 W VICTORY BLVD	91606	2	180B161  1052	2325032005	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	06/16/2020 12:00:00 AM		Permit Finaled	12/15/2021 12:00:00 AM	ADDRESS	34.18683	-118.41194	CHANGE OF USE TO A NEW 2 STORY DENTAL OFFICE AND SERVICE UPGRADE TO 800 AMP.POWER & ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22087	17041-20000-38699	5406 N CREBS AVE	91356	3	174B121   721	2161006021	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM			Reviewed by Supervisor	11/01/2017 12:00:00 AM	ADDRESS	34.16921	-118.54355	install (2) tesla power wall.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22088	13041-10000-03453	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Tenant improvement at the existing Camille's Sidewalk CafePlan chk is for Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22089	17041-10000-06120	580 S ALAMEDA ST Unit A	90013	14	126A215   246	5164009001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.03894	-118.23818	Plan check for Title 24 only in existing space T.I. Total area: 2,170 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22090	19041-10000-50690	2131 N ROSCOMARE ROAD	90077	5	150B145    70	4377013009	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.10969	-118.46371	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 18.13KWdc (14.21KWac & 16.59 KWcec) USING 49  LG370Q1C-V5 MODULES &  ENPHASE IQ7PLUS-72-2-US MICROINVERTERS. CONNECTED TO A 225 AMP NEW SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22091	19041-10000-07317	8525 N TELFAIR AVE	91352	6	192B169   321	2632023047	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Issued	06/12/2019 12:00:00 AM	ADDRESS	34.22421	-118.384	POWER PLAN CHECK FOR SERVICE UPGRADE WITH NEW EQUIPMENT; SCOPE INLCUDES ONE 1200-AMP 277/480V 3PHASE 4WRIE RECONNECTING ALL EXISTING CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22092	16041-10001-36967	11562 W OTSEGO ST	91601	2	171B169   624	2354002011	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			PC Approved	10/31/2016 12:00:00 AM	ADDRESS	34.16296	-118.38444	PV1 roof mounted solar system installation to a single family home. Installing 31 optimizers connected with a  central inverter rated at 7.6 KW.  Note: permit was pulled online under application number: #16041-90000-36967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22093	19041-20000-43396	3471 W BEN LOMOND PL	90027	4	150B201    55	5591003018	R1-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.11125	-118.28216	PV1. INSTALL 5.04 KW DC PV SYSTEM WITH (16) MODULES/OPTIMIZERSE AND (1) INVERTER (SE5000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22094	13041-20001-25872	810 E PICO BLVD 4th Floor	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Expired	12/07/2016 12:00:00 AM	ADDRESS	34.03119	-118.25079	changes to approved set of plans. check for T24 only. some power changes. recheck for delta 2 revisions. (((T24 FOR EXISTING MALL 4TH FLOOR.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22095	18041-30000-05337	1125 S GAYLEY AVE #305	90024	5	132B149   114	4363023033	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM			PC Approved	02/15/2018 12:00:00 AM	ADDRESS	34.05968	-118.44624	Plan check for Title 24 only in existing space T.I. office space. total newly connected load less than 400A. Tota area: 2752 sq ft. Plan check only Permit was pulled under application #18041-30000-03696	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22096	18041-10000-35922	10117 S AVALON BLVD	90003	8	091-5A207 224	6063005028	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	33.94415	-118.26532	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22097	15041-20003-34756	740 S RIDGELEY DR	90036	4	132B181   133	5089005011	[Q]R4-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			08/16/2019 12:00:00 AM			PC Info Complete	08/16/2019 12:00:00 AM	ADDRESS	34.06127	-118.35077	Revisions to approved set of plans.  Change of feeder detail from copper to aluminum, addition of sewage ejectors.  Approval for clouded portions only.  (((PC FOR POWER AND ENERGY. 5-STORY 25-UNIT APARTMENT BUILDING WITH 2 LEVEL GARAGE .6 TYPES APRTMENT. TOTAL AREA 22,000 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22098	16041-10001-25610	4553 S GLENCOE AVE #500	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	33.98415	-118.43328	THIS IS A PLAN CHECK AND SUPPLEMNTAL PERMIT FOR ADDITIONAL 3 PANELS THAT ARE NOT COVERED BY THE MASTER PLAN.NEW DESIGN BUILD F/A SYSTEM,  (5) FA PANEL ,   (114) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22099	12041-20002-05946	4901 S FIGUEROA ST	90037	9	111A201   136	5018023028	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	33.99854	-118.28288	Supplemental plan check to 12041-20000-05946. Change in fault current from 35000 to 52000.(((( PLEASE IGNORE 12041-20000-05946, plan check was over the counter, not backroom ))))coin laundry	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22100	16041-10005-15028	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Closed	12/14/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	CHANGES TO APPROVED SET OF PLANS. ASSITIONAL SCOPE OF WORK, ADDED PANEL WITH A FEW CIRCUITS IN IT ROOM. NEW LIGHTING AND RECEPTACLES. REMOVAL OF SCOPE OF WORK AND ADDITION OF SPDS. PC FOR DELTA DCN-025 AND DCN-33.  PERMIT TO BE ISSUED FOR ADDITIONAL ITEMS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22101	14041-20000-12087	14800 W VENTURA BLVD 8th floor	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.15186	-118.45547	Plancheck for power. New switchboard and related feeders serving AT&T communications equipment in an (E) AT&T-owned highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22102	12041-20000-11812	3138 W PICO BLVD	90019	10	129B193  1332	5073008001	C2-1VL	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Info Complete	07/05/2012 12:00:00 AM	ADDRESS	34.04701	-118.31048	T.I. to dollar tree store.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22103	11041-10000-08335	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM			PC Approved	04/26/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	TI TO AN EXISTING OFFICE BUILDING.  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22104	19041-10000-13289	11880 W JUNIETTE ST	90230	11	105B165   304	4220005034	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.98564	-118.40381	PV1. NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 7600 INVERTER,  (20) MODULES + OPTIMIZERS, AND (1) TESLA POWERWALL . TOTAL SYSTEM SIZE IS 6.4KWAC AND 7.2KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22105	19041-10000-18321	1718 N SAN REMO DR	90272	11	135B133   169	4432007021	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Issued	08/09/2019 12:00:00 AM	ADDRESS	34.06368	-118.50017	PLAN CHECK FOR POWER ONLY. SCOPE OF WORK INCLUDES A REMODEL TO AN EXISTING TWO STORY SINGLE FAMILY DWELLING AND INTERIOR REMODEL. NEW 600 AMP, 120/240, 1PH SERVICE, PANELS AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22106	07041-20002-27847	10209 N HILLHAVEN AVE 1-10	91042	2	204B197   937	2565012051	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			05/19/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	07/13/2010 12:00:00 AM	ADDRESS	34.2545	-118.29003	Suplimental to existing approved plan. Change clouded which indicate upgrading of sub panel to 200 and adding one additional sub panel 100 amp panel and 6 more circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22107	16041-20000-44615	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	PLAN CHECK FOR POWER AND ENERGY.  COMPLETE NEW ELECTRICAL SYSTEM. RENOVATION OF AN EXISTING 5 STORY, TYPE I BUIDING AND AN EXISTING 1 STORY, TYPE V BUILDING TO INCLUDE A CHANGE OF USE TO A PRIVATE CLUB WITH ACCESSORY MUSIC ROOM, RESTAURANTS, BARS, OUTDOOR DINING, RETAIL, GYM, PRESENTATION ROOM, 48  guest rooms FOR USE BY PRIVATE CLUB MEMBERS ONLY (HOTEL).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22108	14041-20000-08644	1901 W 6TH ST 1-53	90057	1	133-5A205 293	5154026001	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			04/01/2014 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.05872	-118.27264	PLANCHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION OF  53-UNIT AFFORDABLE APARTMENT BUILDING OVER BASEMENT PARKING WITH 5 STORIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22109	17041-10000-38136	5645 W ADAMS BLVD	90016	10	123B173   815	5048003061	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			Reviewed by Supervisor	11/01/2017 12:00:00 AM	ADDRESS	34.03262	-118.36644	PC for change of use from warehouse to restuarant/brewery. Installing new 800A 120/240V service and service equipment. Installing five panels, new equipment, receptacles and lights. Total area Indoor + Outdoor= 15080 sqft. Build# 17016-10000-07980.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22110	14041-10000-14925	11906 W SARAH ST	91607	2	168B169   897	2364004014	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.15388	-118.39241	PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERACT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22111	14041-10000-02081	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	New fire alarm system installation in medical office building.  587 new devices covering 194,060 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22112	14041-10000-30595	11105 N MCVINE AVE	91040	7	210B193   439	2551045001	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.27066	-118.31163	PV 1 System size: 5KW with 18 modules(TSM-PA05.18 The Trinamont Module) and 1 inverter (3.3KW Solar Edge)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22113	13041-10000-16701	6362 W SUNSET BLVD	90028	13	147A187   584	5546015047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.09774	-118.32787	Tanning salon TI.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22114	11041-20000-16211	1216 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/08/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.2922	"New 3.23 Kw Pv solar equipment ( max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) system for an appartment Bldg"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22115	13041-10000-27078	1901 1/2 S BUNDY DR	90025	11	123B149   379	4259019012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/30/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.03435	-118.45789	fa for parking structure. 1 facp 1 ann, 3 power supply, 120 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22116	15041-20000-22575	7611 COURAGE WAY	91405	6	186B145  1152			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20904891	-118.46444937	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22117	13041-10001-32313	2134 N THOMAS ST	90031	1	136-5A225  11	5211007013	RD3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			Reviewed by Supervisor	11/27/2013 12:00:00 AM	ADDRESS	34.07015	-118.20501	Expedited RSES plan check per applicant request. (((( PV1, Install 2.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22118	17041-10000-11246	3000 S ROBERTSON BLVD #100/105	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	PC FOR ENERGY ONLY, CONNECTED LOAD < 400A,M Tenant improvement 1st floor office, TOTAL AREA 5970 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22119	19041-10000-31456	12061 W LUCILE ST	90230	11	105B161   556	4220013023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.98457	-118.40897	[EPLAN] PLAN CHEK FOR ROOF MOUTED 11.4KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 39 MODULES USING P400 OPTIMIZERS CONNECTED TO AN EXISTING 200A PANEL.MAIN PANEL DERATING SHALL BE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22120	15041-20001-08914	6256 N TOPANGA CANYON BLVD #2280C	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	Changes to approved set to reflect field conditions.  Changes to light fixtures and relocation of switchbank.  Relocating one panel from attic to kitchen area.  Slight relocation of bot transformers.***** Previous Work Description*****Plan check for power and Title-24 (energy).  Total area = 6,798 sq. ft.T.I. to restaraunt.  First time tenant.  New 75 kVA and 45 kVA transformers feeding 4 new panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22121	17041-10002-14845	1019 S CATALINA ST	90006	1	129B197   297	5078013005	C2-1, R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.05214	-118.29493	PC FOR Chages to approved set for new  FA SYSTEM.SCOPE INCLUDES REMOVAL OF LOW FREQUENCY DEVICES AND ADDITION OF 2 RPS'S.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22122	13041-10000-19450	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	pc for power only. HYPERION DICE II CENTRIFUGE #8 REPLACEMENT. installation of 480V 600A panel serving 300HP and 75HP motors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22123	17041-10000-08007	4707 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/25/2017 12:00:00 AM	ADDRESS	34.04709	-118.33933	Plan check for Energy only (T-24), on (E) CVS pharmacy, 849 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22124	13041-10000-13341	10443 W LA CANADA WAY	91040	7	204B177    64	2543002006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.25708	-118.35667	PV1 15kw  2 STORY HOUSE. nonSTD. ROOFMOUNT.  [ (2x) INV:  sunpower psr 8000m and 6000m6kw and a 8kw ][MOD: sunpower spr 327ne-wht-D ] . positive ground	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22125	19041-30000-22280	15164 W OXNARD ST	91411	4	177B145   464	2243019011	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.17918	-118.46392	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to warehouse/manufacturing. Total lighting area = 5,600 sq. ft.Note: Building application has been generated under 19016-20000-17587. Per applicant, no hazardous locations are part of this scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22126	17041-10000-17306	1128 S LOS ANGELES ST	90015	14	126A209   299	5145021004	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Info Complete	05/23/2017 12:00:00 AM	ADDRESS	34.03751	-118.25762	REPAIR OF WAREHOUSE BUILDING. REBUILD LIGHTING SYSTEM. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22127	14041-20000-29655	525 W 7TH ST	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	34.04722	-118.25617	PLANCHECK FOR T24 ENERGY ONLY. CHAGE OF USE FROM RETAIL/TAKE-OUT JUICE BAR TO RESTAURANT ON GROUND FLOOR. 2720 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22128	19041-10000-05025	3415 S SEPULVEDA BLVD #1250	90034	5	120B157   960	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.02055	-118.42347	T-24 ONLY PC FOR A TI OF AN OFFICE SPACE IN A HIGHRISE. SUITE #1250. SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 3155 SQ.FTB# 19016-10000-01315	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22129	10041-20000-16389	22554 W VENTURA BLVD #201	91364	3	171B097   246	2040033039	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1372.01	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	11/18/2010 12:00:00 AM	ADDRESS	34.16731	-118.6184	"T.I. to existing building (2nd floor) from dental to general medical practice.  No electrical medical equipment installed.  Install new branch circuits on the existing panel ""A"" as shown on the plans.  Lighting plan check is under a separate permit.  Plan check for power only."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22130	15041-10000-05699	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011065	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.98173	-118.4029	New fire alarm system for a commercial building(bld-2); work includes (1) fire alarm panel, and (14) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22131	18041-10000-25534	4204 S EAST BLVD	90066	11	111B157   473	4233007027	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.00077	-118.42008	$0.00 FEE DUE TO SENATE BILL 1222 & aAB1414PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.91KWdc / 11.76KWac(42)MODULES-LG NEON R 355(42)MICROINVERTERS-ENPHASE IQ6PLUS-72	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22132	15041-10000-06371	201 W WASHINGTON BLVD	90015	14	123A207    51	5126027007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.03222	-118.26683	New sprinkler monitoring system with (1) fire alarm panel, (1) communication panel, and (8) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22133	10041-10000-22352	1712 W PACIFIC COAST HWY	90717	15	033B193    51	7553018023	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.05	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	07/21/2011 12:00:00 AM	ADDRESS	33.7893	-118.30821	TI for Mcdonald restaurant, replacing a panel, adding new light fixturs on existing circuits.  EPC is for T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22134	19041-10000-26213	7083 W HOLLYWOOD BLVD 4th FLOOR	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	09/02/2020 12:00:00 AM	ADDRESS	34.10173	-118.34439	TENANT IMPROVEMENT IN AN EXISTING COMMERCIAL OFFICE ON THE 4TH FLOOR OF A LOW RISE BUILING. INSTALLING LIGHTS. T-24 ENERGY ONLY. AREA OF WORK: 1,612 SQR FT. BUILDING PERMIT: 19016-10000-20630	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22135	16041-20000-21187	10355 W DIAMOND ST LOT 4	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22136	18041-20002-20772	14235 W OXNARD ST	91401	6	177B153   828	2240025028	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.17954	-118.44357	02-14-2019, Plan check for lost set of plans. Plan check only permit covered under master application. ********************PreviousWork Description. *******************************2-STORY ADDITION FOR COMMERCIAL STORAGE BUILDING.  PLAN CHECK FOR LIGHTING ENERGY CONSERVATION REQUIREMENTS. TOTAL AFFECTED AREA 6025 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22137	16041-10001-17752	14006 W RIVERSIDE DR #19	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/11/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	07/11/16PLAN CHECK FOR A LOST SET OF PLANS. NOTE: ORIGINAL APPLICATION IS UNDER PCIS#16041-10000-17752(((((T-24, PC FOR ENERGY ONLY.  TI TO AN EXISTING COMMERCIAL BUILDING (RETAIL STORE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1392 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22138	16041-10000-23378	4135 S 11TH AVE	90008	10	114B185   484	5024026022	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.00898	-118.32971	PV1 installation of a roof mounted system to a single family home. Installing a central inverter rated at 3.8 kw, 12 modules(solarworld SW280), and 12 optimizers Solaredge P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22139	18041-10000-10686	1310 N TAMARIND AVE	90028	13	144B189    37	5545015060	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	02/25/2021 12:00:00 AM	ADDRESS	34.09479	-118.3189	Plan check for new fire alarm system appartment building. New fire alarm devices: 112	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22140	16041-20000-45631	3900 N STANSBURY AVE	91423	4	162B153  1094	2274027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.14084	-118.44264	Addition and remodel of upper and lower level of two-story school building.  Plan check for energy - 11,000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22141	16041-20000-38503	17548 W SAN FERNANDO MISSION BLVD	91344	12	210B129   360	2712004021	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.27194	-118.51701	"""0$ permit fees due to senate bill 1222""Plan check for installation of pv system, roof-mounted on SFD. Interconnect with a 200A MSP.13.44kW ungrounded system. (56) EnPhase M250 microinverters. (56) 285W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22142	18041-10000-34186	2080 S CENTURY PARK EAST	90067	5	132B161    39	4319001014	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM			PC Info Complete	01/04/2019 12:00:00 AM	ADDRESS	34.05884	-118.41206	"PLAN CHECK FOR TITLE 24 ONLY FOR - INSTALLATION OF 16' 10"" X 16' 0""  OXYGEN SYSTEM W/EQUIPMENT SCREEN WALL ON GROUND LEVEL OF (E) SUB GRADE LEVEL PARKING STRUCTURE - TOTAL AFFECTED AREA = 415 SF"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22143	18041-20001-03337	19344 W CLYMER ST	91326	12	207B117   371	2728006012	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM			PC Approved	07/09/2018 12:00:00 AM	ADDRESS	34.26206	-118.55476	Revisions to approved set.  Addition of ATS to system design for transfer of power from utility to ESS for back-up panel.  (((PV1.  Install 8.9 kW DC, 7.6 kW AC roof mounted PV system with battery back-up.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22144	13041-10002-00977	380 WORLD WAY Space T34	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes made to previously approved set,  addtion of 7 new circuits and lighting control panel , delta changes.  12-23-2013  mzTI 1ST TENANT FOR TOM BRADLEY TERMINAL. THE LARDER AT TAVERNPROPOSED 1813 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE  CONCESSION (The Larder at  Tavern).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22145	19041-10000-51108	5162 N VINCENT AVE	90041	14	163-5A225 240	5669016001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.14129	-118.20214	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 28 MODULES (Q-CELL 285) , 28 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 7.98KWdc and 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22146	12041-10000-30549	8511 W BEVERLY PL	90048	5	138B173   350	4337012040	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.07669	-118.37705	NEW  4 STORY  PRIVATE SCHOOL BUILDING OVER ONE SUBTERRANEAN LEVEL OF PARKING. PLAN CHECK FOR POWER AND ENERGY FOR AN ADDITION TO AN ACADEMY (CHARTER SCHOOL). PROJECT IS LOCATED IN A METHANE ZONE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22147	14041-20000-24403	14715 W AETNA ST	91411	6	177A149    67	2241025001	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Expired	03/21/2017 12:00:00 AM	ADDRESS	34.18023	-118.4536	PC FOR POWER ONLY. NEW 600A SERVICE 3 PHASE 4WIRE DELTA. SERVICE UPGRADE FROM 400A SINGLE PHASE. NEW PANEL WITH NEW 3 PHASE LOADS. NO LIGHTING. EXISTING LOADS TO BE RECONNECTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22148	16041-10001-31791	13701 W VENTURA BLVD	91423	4	165B157   607	2271018008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM			PC Approved	11/28/2016 12:00:00 AM	ADDRESS	34.14822	-118.4314	11/28/2016 Changes to an approved set of plans. Changes include add new lighting fixtures. Changes apply to delta 1 only Total area: 1,425 sq ft. TI FOR RESTAURANT. CHECKING FOR NEW LIGHTING T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22149	17041-10000-06315	970 W 190TH ST SUITE 610	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	33.85812	-118.29302	PC for T-24 only for office space with total area of 1328 sqft. Installing new lights and receptacles. Installaed load under 400 Amp%TI WORK ON 1362SF OF THE TOTAL FLOOR AREA. NEW NON LOAD BEARING INTERIROR PARTITIONS, POWER, LIGHTING, AND FINISHES. SUITE 610	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22150	19041-20000-31255	10947 W CHALON ROAD	90077	5	141B145    16	4369006013	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.08569	-118.45845	Plan check for PV roof mounted system, System size: 12.285KW, with 39 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22151	14041-20000-21489	8020 N LAUREL CANYON BLVD	91605	6	189B165   368	2310015006	C2-1VL, P-1VL, R1-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM			Corrections Issued	09/26/2014 12:00:00 AM	ADDRESS	34.21629	-118.39632	new 400 amp service to an existing one story medical facility.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22152	15041-20000-41657	2917 S FLOWER ST	90007	9	120A203    20	5123019019	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Info Complete	12/11/2015 12:00:00 AM	ADDRESS	34.02486	-118.27677	PC for Energy only. Total area 5,333 sq ft. (indoor+outdoor)(((Project scope includes (1) Change of use from market to office, (2) Interior and exterior TI to include new ramp and new bathrooms, and (3) Add one disabled access parking stall.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22153	14041-20000-25613	23300 W SANDALWOOD ST	91307	12	186B093   642	2027009016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.20267	-118.63598	PV1Central/String inverter simplified standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.6kW.(2) SolarEdge SE3800A-US transformerless inverters(34) SolarEdge P300 power optimizers(34) LG Mono X 275S1C-B3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22154	07041-20006-05924	16710 W VENTURA BLVD	91436	5	168B137   335	2289020018	(T)(Q)C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Apartment			05/24/2011 12:00:00 AM			PC Approved	06/08/2011 12:00:00 AM	ADDRESS	34.15819	-118.49729	Plan check for revision to approved plans. Delta 10 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22155	19041-20001-40600	15564 W OTSEGO ST	91436	5	171B141   282	2261032019	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM			PC Approved	10/25/2019 12:00:00 AM	ADDRESS	34.16308	-118.47408	PLAN CHECK FOR A NEW PV SYSTEM USING  AC MODULES. TOTAL SYSTEM SIZE IS  3.6KWAC / 4KWDC________________________________________________________________Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22156	17041-10000-41795	10409 W WASHINGTON BLVD	90232	5	117B165   227	4208007015	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Issued	11/17/2017 12:00:00 AM	ADDRESS	34.01861	-118.40291	Remove Outdoor HID fixtures and replace with new LED fixtures. T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22157	13041-20001-31893	12845 N SEAGLASS	90094										Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM				((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22158	19041-20002-01479	3449 S MCLAUGHLIN AVE	90066	11	117B157   624	4249022004	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.01524	-118.42991	4-1-19 changes to an approved set of plan, changes include rewiring two telsa powerwalls changing from two AC disconnects to a 60A sub panel. Plan check only. Clouded changes only01-17-2019 Changes to an approved set of plan, changes include reloacte equipment( Powerwall and disconnect) All changes has been cloued. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22159	15041-10000-04756	12746 W JEFFERSON BLVD SUITE 3170	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR POWER AND ENERGY. FIRST TIME TENANT  FOR YOGA STUDIO.. 3 STORY BUILDING. TOTAL AREA6809 SQ FT.B # 15016-10000-03270	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22160	18041-10000-28741	927 N EVERETT ST	90026	1	213B113   266	2701004047	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1977.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	02/09/2023 12:00:00 AM	ADDRESS	34.0683	-118.24946	PLAN CHECK FOR POWER AND ENERGY FOR - NEW 2-STORY CORE AND SHELL RESTAURANT BUILDING WITH OFFICE SPACE- SERVICE SIZE = 600A DELTA SYSTEM. TOTAL AFFECTED AREA = 2867SF BUILDING PERMIT # 16010-10000-06193	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22161	18041-20000-08591	149 1/2 E 78TH ST	90003	9	099B205   401	6022007029	R1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Issued	03/08/2018 12:00:00 AM	ADDRESS	33.96888	-118.27222	pv2install roof mounted pv system sized 2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22162	17041-10000-19745	6406 S MAIN ST	90003	9	105B205  1116	6006015900	PF-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	33.98117	-118.27376	PLAN CHECK FOR ENERGY ONLY - REPLACE  LIGHTING FIXTURES TO LED TYPE(13500 SQ. FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22163	18041-20000-00370	3520 W COUNCIL ST	90004	13	138B197   610	5501007025	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.07479	-118.28748	ti to an existing commercial building.  adding new lightign new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22164	16041-20001-25352	20948 W KNAPP ST BLDG 1	91311	12	198B109   211	2746009041	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.23844	-118.59063	09/29/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the circuit breaker for subpanel B2.*****Previous Work Description*****TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  THIS IS BUILDING 1 SUBFEEDING BUILDING 2.  TOTAL QUARE FOOTAGE 9726.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22165	14041-20000-24387	10151 N KEOKUK AVE	91311	12	204B113   340	2741010027	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.2553	-118.57435	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING 18 MODULES. USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22166	13041-10000-08693	147 N WESTERN AVE	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10, 2115.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	05/06/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	34.07441	-118.30931	RENOVATION OF PREVIOUS RETAIL SPACE. CHANGE OF USE FROM RETAIL TO COUNTER SERVICE RESTAURANT. NO PLAN CHECK REQUIRED, SMALL LOADS. PLAN CHECK FOR TITLE 24 ONLY. ENERGY COMPLIANCE. TOTAL AREA 1065 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22167	14041-10000-02985	3342 N VERDUGO ROAD	90065	1	153A215   288	5456001046	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM			Reviewed by Supervisor	03/21/2014 12:00:00 AM	ADDRESS	34.11279	-118.23548	"PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT TO RANCHO MARKET TO REPAIR INTERIOR PARTITIONS  DUE TO FIRE DAMAGES. EQUIPMENT RATED  OVER 600AMPS.""COMPLY WITH DEPARTMENT ORDER effective date08/13/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22168	13041-10001-22033	1026 S ALFRED ST	90035	5	132B173   454	5087006025	R2-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM			Reviewed by Supervisor	08/23/2013 12:00:00 AM	ADDRESS	34.05855	-118.3748	][]EXPEDITE PLAN CHECK PER APPLICANT REQUEST[][][][]PV1 ROOF-MOUNTED INSTALLATION ; SYSTEM SIZE AT 7 KW. (28) MODULES: PHONO 250P-20/U(28) ENPHASE M215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22169	16041-20000-38734	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			PC Approved	01/20/2017 12:00:00 AM	ADDRESS	34.04538	-118.26335	Plan check for power and energy.  Interior TI work on all floors of existing 4 story building - including improvements to existing auditorium, dining space, and office space. New load >400A. New lighting (incl. emergency). 31,228sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22170	17041-30000-19830	633 W 5TH ST 49th Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project site is a portion of the 49th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,940 sq. ft.Note: Building application has been generated 17016-10000-14504	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22171	16041-20000-08781	6935 N TOBIAS AVE	91405	6	183B149   479	2219013006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Issued	04/04/2016 12:00:00 AM	ADDRESS	34.19669	-118.45213	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.35 KW(50) SUN POWER SPR-327 MODULES(1)  ABB PVI-5000(2)  ABB PVI-6000Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22172	13041-10001-01417	380 WORLD WAY T19	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Info Complete	03/07/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	delta 1 changes to previuosly approved setFirst time tenant space T19 (DUTY FREE SHOP) on 4th floor at Bradly West Terminal LAX.  Install tranformer, panels, and branch circuits.  Plan check for power and energy.   Filed for variance to separate fire alarm plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22173	16041-10001-00371	14006 W RIVERSIDE DR #204	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC FOR POWER ONLY, TI IN A RETAIL SPACE. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES, TWO TRANSFORMERS AND NEW PANELS. CONNECTED LOAD IS > 400AMPS.  PC FOR ENERGY IS UNDER THE MASTER APPLICATION 16041-10000-00371. (((T-24, TI TO AN RETIAL SPACE INSIDE A MALL. SCOPE OF WORK INCLUDES NEW PANELS, LIGHTS AND RECEPTACLES. . TOTAL SQ. FT. 9545.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22174	15041-30001-41233	8957 W DAVID AVE	90034	10	126B169   871	4302017030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.04024	-118.38669	04-14-16 Change to approved set of plans. Changes include module layout on roof of garage to roof of house and addition of 2 modules & microinverters(Enphase M250-60-2LL-S22) & load center. ((((((Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 4 kWac.  Microinverter system with 1 branch.))))))))))Note: Fees $0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22175	19041-10001-08326	6160 N LAUREL CANYON BLVD #C	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.18234	-118.39628	"Plan check only. Wet restamp and pereferate scanned copy of approved pereferated set to replace lost original set NEW FIRE ALARM SYSTEM IN BUILDING ""C""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22176	10041-10002-17816	1006 E 28TH ST	90011	9	118-5A209 315	5128022009	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Apartment			08/07/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	ADDRESS	34.01717	-118.2574	As built set of drawings per inspector. Some outlets have been removed and other outlets have been changed from wall outlets to floor outlets. Original plan number is 10041-10000-17816.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22177	13041-10000-28690	400 S HOPE ST 7TH FL	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.05199	-118.25366	REMODEL BATHROOMS AND CORRIDORS OF OFFICE SUITEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22178	14041-20000-00980	16738 W SUNBURST ST	91343	12	195B137    70	2688024045	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.23467	-118.49765	pv1 single family dwelling. total system size 6kw ac using 4 strings transformerless inverter using 20 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22179	17041-10000-11328	4705 S NORMANDIE AVE	90037	8	111B193   682	5016020002	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2322.00	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.00071	-118.30033	PC for energy only, Indoor T-24. Removing HID fixtures and replacing them with new LED ones. Area: 4800. Total of 8 fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22180	15041-10000-41089	3406 W ADAMS BLVD	90018	10	123B189   720	5052015006	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Closed	04/07/2016 12:00:00 AM	ADDRESS	34.03242	-118.32183	NEW FIRE ALARM SYSTEM FOR RETIREMENT HOME. 1 FIRE ALARM PANEL AND 88 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22181	19041-10000-41086	12640 W RIVERSIDE DR	91607	4	168B161   469	2357032003	C1-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.15745	-118.40873	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22182	16041-10000-15609	13568 W POLK ST	91342	7	228B157    38	2582013011	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.32556	-118.42954	PV1, rooftop solar installation 10kW AC    (36) CS6P-265P      (1) SE10000A-US        SEP300 is used.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22183	16041-20001-04051	330 W OLYMPIC BLVD	90015	9	127-5A209 252	5139012013	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.04204	-118.2594	CHANGES TO AN APPROVED SET OF PLANS.  EM LIGHTING BUG LIGHTS.New Restaurant 600A MS. PC for Power and Energy (Build App. 08016-10000-09013). T-24 per 2008 CodeTotal area: 9584 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22184	16041-30000-38096	1601 E OLYMPIC BLVD #505	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.02923	-118.24056	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22185	12041-10000-24726	100 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	11/08/2012 12:00:00 AM	PIN	33.94684048	-118.40128468	Plan check for Fire Alarm System for LAX Terminal 1(((((((( 11/08/20012  This was a plan check only and the contractor has already pulled the permit  for this job and the permit number is 11041-10001-25687 )))))))))))))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22186	14041-20000-14380	800 W WILSHIRE BLVD #102	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.0493	-118.25841	TI for (E) restaurant space in existing commercial highrise building.  Title 24 plan check for changes to lighting system.  Newly connected load below 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22187	14041-20000-15810	3501 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.02194	-118.28455	pc for new lighting in existing lobby. total area about 1500 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22188	16041-10000-11365	1301 S MAIN ST	90015	14	124-5A207  94	5133010016	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.0365	-118.26067	(TI) CHANGE OF USE FROM RETAIL TO OFFICE AT 2nd FLOOR LEVEL.  PC FOR T-24 ONLY. TOTAL AREA: 8,677 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22189	19041-20000-20614	11663 N SHEFFIELD WAY	91326	12	213B125    84	2870018009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.28351	-118.53167	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWdc/10.2 kWac-CEC and consists of (32) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22190	10041-10000-09651	1820 E INDUSTRIAL ST #104	90021	14	124-5A2171372	5164021121	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	05/21/2010 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.03563	-118.23389	CHANGE of USE of FIRST FLOOR TENANT SPACE TO COFFEE  SHOP  (TAKE OUT)plan chkis for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22191	18041-20000-12664	4821 N FORMAN AVE	91601	4	168B177   438	2420016018	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.15841	-118.35305	Plan check for PV roof mounted system, system size: 11.4kW with 33 modules and 1 inverter Solaredge(11.4kW) connect to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22192	17041-20002-14475	812 W 165TH PL	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	33.88061	-118.28977	Revisions to approved plans.  Relocation of inverters and 200A subpanel to second floor exterior wall.  (((PV2. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTERS. SYSTEM SIZE: 50KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22193	17041-10000-28438	18574 W MARILLA ST	91324	12	201B121   437	2763033041	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	PIN	34.24674914	-118.53870804	200 AMP PANEL UPGRADE	N	N	Express Permit	06/10/2024 12:00:00 AM
22194	18041-20002-36419	17236 W ELKWOOD ST	91406	6	189B133   713	2204013014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.21266	-118.509	Revisions to approved set of plans.  Subpanel specified as Generac ATS panel.  $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.  (((Plan check for a PV1 roof-mounted PV system. System size is 12.95 kWdc/15.2 kWac and consists of (2) inverters, (37) modules, (2) batteries, (2) load centers, and (1) transformer.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22195	19041-20001-11993	827 N VINE ST flr 1-3	90038	13	141B185   150	5533030031	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	02/04/2022 12:00:00 AM	ADDRESS	34.08598	-118.32689	Revision to approved set.  Additional distribution equipment and changes to architectural layer/reconfigure circuit layout.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22196	16041-20001-15917	542 S ALAMEDA ST	90013	14	126A215   141	5163027011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.04014	-118.23809	6/15/17changes to an approved set of plans.  changes include service load calculations, addition of electric car lift motor and ev charger.NEW 1200 AMP SERVICE TO A NEW INDUSTRIAL WAREHOUSE TWO STORIES.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 12030.Note: Building application has been created under 16016-10000-10209	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22197	16041-20001-16021	23308 W BERDON ST	91367	3	174B093   448	2044001024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM			PC Approved	05/14/2016 12:00:00 AM	ADDRESS	34.17081	-118.63455	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(60) KYOCERA MODULES(2) ABB INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22198	11041-10000-16316	505 S FLOWER ST B-430	90071	14	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.0515	-118.25654	tenant improvement in restaurantplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22199	13041-10001-27350	21717 W NORDHOFF ST	91311										Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.23562	-118.60243	EXPEDITE FEES ONLYNew 91.56kw PV system to be connected directly to the utility (not to feed the building).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22200	16041-20000-36942	21300 W NASHVILLE ST	91311	12	210B105   188	2706032025	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.26892	-118.5958	PV1.  Install 6.2 kW DC roof mounted grid-tied PV system.  (24) modules with (1) 5kW rated inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22201	13041-10000-33876	777 E 12TH ST STE 1-12	90021	14	123A211    59	5132010036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.03264	-118.25093	Plan check for T24. Remove HID light fixtures and replace with new fluorescent fixtures in commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22202	13041-20000-14784	13285 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24 KW. 15 PANELS IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22203	17041-20001-20715	3200 W ADAMS BLVD	90018	10	123B189   714	5052015032	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.03243	-118.31875	PLANCHECK FOR T24 ENERGY. PLANCHECK ONLY.  T.I. OF OFFICES IN CHURCH ANNEXPERMIT PREVIOUSLY PULLED UNDER 17041-10000-20715.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22204	18041-20000-17981	20753 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Issued	05/15/2018 12:00:00 AM	ADDRESS	34.29515	-118.58642	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22205	15041-10001-16417	11818 W WILSHIRE BLVD UNIT 300-PHASE 5	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.0474	-118.46308	UPDATED POWER PLAN TO SHOW NEW CRYO ROOM, FREEZE/THAW ROOM, LIGHTING PLAN TO SHOW GYP BD CEILING WITH 4 N FIXTURES  IN NEW FREEZE ROOM. PHASE 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22206	18041-10000-28654	12124 S MENLO AVE	90044	15	084B197   572	6117007020	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	33.92208	-118.28902	PLAN CHECH FOR A ROOF MOUNTED PV SYSTM FOR A 6KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLAREDGE SE6000H-US) WITH 22 PANELS USIG P320 POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22207	12041-20000-07941	9649 W LAWLEN WAY Main House	90210	5	147B161   405	4355019044	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.09484	-118.41636	Remodel an existing house and upgrade the service to 1600amperes, install new service, switchboard, subpanels, and branch circuits.  The new service supplies also a guest house and a wellness center located on the same lot and owned by the same owner, and standby generator is also provided.  A separate permits will be required for the guesthouse with application number  12041-20000-24710, and wellness center with application number 12041-20000-24720.  Full plan check for all buildings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22208	12041-20001-21423	17923 W CHATSWORTH ST	91344	12	207B129   356	2715025048	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	ADDRESS	34.26507	-118.52442	"Modification to previously approved set of plans.  Change to feeder sizes and breaker types only.  PLAN CHECK ONLY for ""DELTA 3"" changes.        <<<<<T. I. RESTAURANT - 2853 SF W/710 SF Patio.  First Time Tenant, per applicant.  Full Plan Check for Power and Energy>>>>."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22209	13041-10000-24285	4917 E YORK BLVD	90042	14	156A223   198	5476017029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.12189	-118.20833	TITLE 24 PLAN CHECK ONLY. PERMIT ALREADY PULLED UNDER 13041 10000 19460. 335 SQFT. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22210	13041-20000-33228	7232 N VAN NUYS BLVD	91405	2	186B149   824	2217003003	C1-1VL, C2-1VL, R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	12/24/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.20224	-118.44846	Change to lighting and loads in an existing Medical Clinic.  Full Plan Check for Power and Energy.  Not State Licensed, NOT Checked for OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22211	16041-10001-28708	18049 W MEDLEY DR	91316	5	165B125   270	2184033008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.14742	-118.52635	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 10kW with 2 inverters(5.0kW) with 28 modules connected to 400 A service Split Bus(200)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22212	13041-10000-16476	6911 W 85TH PL	90045	11	096B161   524	4112002012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	33.9605	-118.41182	PV1.  Install 8.0 kW DC roof-mounted solar array, interconnect into existing main service panel.  {32 modules: Trina Solar TSM-250PA05.08} {2 inverters: Power One Aurora PVI-3.8-1-OUTD}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22213	13041-20000-05680	9916 N TELFAIR AVE PV-1	91331	6	201B161   230	2624006035	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.2501	-118.41112	PV-1. Plan check for micro inverters. 6.0kW system (5.16kW inverter total).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22214	12041-20000-07126	11704 W WILSHIRE BLVD STE 11710	90025	11	129B145   644	4263009030	R4-1, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	04/24/2012 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	ADDRESS	34.04906	-118.46104	Medical office.  Install X-Ray equipment, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22215	18041-10000-20089	1263 W TEMPLE ST	90026	1	136-5A209 349	5160023014	CW	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.06637	-118.25408	TI in an existing Restaurant/Bar 2,160 sf. Title 24 - Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22216	14041-10000-00320	1222-1230 W 7TH ST	90017	1	130-5A207 165	5143009014	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.05171	-118.26665	PLAN CHECK FOR POWER. UPGRADE OF SERVICE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22217	14041-20000-11855	2080 S CENTURY PARK EAST 210	90067	5	132B161    39	4319001014	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.05884	-118.41206	PLAN CHECK FOR POWER AND ENERGY FOR T. I. TO (E) MEDICAL OFFICEOSHPD 3 project	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22218	18041-10000-45481	215 N TOLUCA ST	90026	1	135A209   210	5160011017	CW	Central	Westlake	Echo Park	YES	2080.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	02/27/2020 12:00:00 AM		Issued	02/27/2020 12:00:00 AM	ADDRESS	34.06387	-118.25728	FULL PC POWER AND T-24. NEW 2000A-120/208V SERVICE. TOTAL SQUARE FOOTAGE = 34805 SFSCOPE OF WORK INCLUDES (60) SMOKE DETECTORS, (67) 3.1-5 HP-KVA EQUIPMENTS, (2) 5.1-20 HP-KVA EQUIPMENTS, (2) 20.1-50 HP-KVA EQUIPMENTS, (812) BRANCH CIRCUITS, (66) 0-200A PANELS, (1) 201-600A PANELS, AND (3) MAIN DISTRIBUTION BOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22219	12041-20000-00923	1880 CENTURY PARK EAST 3rd 7 10th-Floors	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	PIN	34.06321806	-118.4136341	Plan check T24 Energy/Emergency for corridors on floors 3rd and 10th floor. Existing ckts.Fire/ Life safety existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22220	12041-10000-07332	1700 W PICO BLVD	90015	1	127-5A203  66	5135020019	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	07/24/2012 12:00:00 AM	ADDRESS	34.04497	-118.27822	NEW FIRE ALARM SYSTEM IN A ONE STROY SCHOOL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22221	15041-20001-25772	5158 W LOS GRANDES WAY	90027	4	153B193   361	5588021040	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	PIN	34.11234397	-118.30319381	*****VOID*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22222	13041-20001-14282	2918 S DANALDA DR PV 1	90064	5	126B165  1029	4316014014	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.03803	-118.40238	(((THIS IS APPLICATION IS FOR CHANGE OF INVERTER REQUIRES PLAN CHECK. PERMIT ALREADY ISSUED UNDER ORIGINAL APPLICATION. THIS SUPP. IS PC FOR PV SYSTEM AND PERMIT FOR MISSING ITEMS.)))INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 7.105 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22223	16041-10000-31835	1326 W ANAHEIM ST	90744	15	030B201   251	7416002003	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM			Not Ready to Issue	05/08/2017 12:00:00 AM	ADDRESS	33.77893	-118.27909	PC FOR T24 ENERGY ONLY. DONUT SHOP. pc only. permit to be issued under supplemental for power system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22224	19041-20000-42554	8836 S READING AVE #1-#8	90045	11	096B169   951	4125017010	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			10/18/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	33.95676	-118.38145	NEW BUILDING WITH 600AMP SERVICE & 9 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22225	15041-10000-29189	1581 E INDUSTRIAL ST	90021	14	124-5A215  35	5164010002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			Not Ready to Issue	09/03/2015 12:00:00 AM	ADDRESS	34.03608	-118.23629	PC FOR ENERGY. TI FOR RETAIL STORE. TOTAL AREA 7908 SQ FT.PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-10000-15223CE INSPECTION FEE PAID 09/3/2015	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22226	19041-10000-08229	10732 N LAUREL CANYON BLVD	91331	7	207B153   176	2616010907	OS-1XL-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.26539	-118.43888	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22227	19041-10000-23824	523 W 6TH ST 600	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.04864	-118.25484	ENERGY PLAN CHECK FOR AN OFFICE TENANT IMPROVEMENT LOCATED ON THE 6TH FLOOR OF A HIGH RISE BUILDING. SCOPE INLCUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 9168-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22228	10041-10000-14270	2709 E MEDIA CENTER DR	90039	1	150B213  3653	5442032001	[Q]M1-1-CDO, [Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.00	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	PIN	34.11096076	-118.24539883	New fire alarm for school.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22229	15041-20001-07426	13215 W OTTOMAN ST	91331	6	195B157   158	2627014023	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.23396	-118.42091	Changes to approved set.  Inverter changed from Power One UNO-7.6-TL to ABB PVI-6000.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (27) modules and (1) inverter. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22230	18041-20000-46363	19554 W HAYNES ST	91335	3	180B117   594	2132011006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.18952	-118.55973	Plan check for PV roof mounted system, system size: 8.64kW DC, 7.44kW AC with 24 PV modules and 6 microinverters and 1 inverter(6.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22231	16041-20000-03541	5901 N DE SOTO AVE	91367	3	177B109   204	2149002028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.17807	-118.5905	PLANCHECK FOR T24 ENERGY. CHG OF USE FROM OFFICE TO HOUSE OF WORSHIP WITH ACCESSORY OFFICE, CHILDREN CARE ROOMS. 2022 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22232	13041-10000-30063	1203 N LAS PALMAS AVE	90038	4	144B185  1343	5532004036	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.09278	-118.33649	PV1, Install 1.59 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US. 6 modules Suniva OPT265-60-4-1B0. 3 story townhouse.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22233	19041-20000-51033	4359 N CAMELLIA AVE	91604	2	165B169   415	2365018010	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/29/2021 12:00:00 AM		Permit Finaled	05/25/2021 12:00:00 AM	ADDRESS	34.14907	-118.38239	PV1.  Install 7.8 kW roof mounted PV system.  (104) roof shingle modules with 6 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22234	13041-10000-08175	1045 S WESTWOOD BLVD	90024	5	132B149    54	4363018014	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	04/02/2013 12:00:00 AM	ADDRESS	34.06161	-118.44559	T24 FOR CHANGE OF USE FROM RETAIL TO BEAUTY SALON. 1961 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22235	17041-10000-19431	525 W 28TH ST	90007	9	121-5A203 138	5123018015	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	34.02644	-118.2765	PLAN CHECK FOR T-24 ONLY - REPLACE EXISTING FIXTURES WITH NEW (11)LED FIXUTES - TOTAL AFFECTED AREA (9675)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22236	16041-20000-19957	23700 W STAGG ST	91304	12	189B089   459	2027032007	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.21057	-118.64461	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22237	15041-30002-37304	3516 S SAWTELLE BLVD	90066	11	117B157   438	4249032045	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Apartment			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.0163	-118.42336	02/09/2017 Changes to an approved set of plan. All changes have been marked as Delta 1. Fault current calculations have been adjusted and the main distribution board fused disconnect rating has increased to 400 amps.*****Previous Work Description*****Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 38.5 kWac.  System consists of 5 7.7 kWac inverter with 27 modules each.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22238	12041-10000-13811	4389 E YORK BLVD	90041	14	157-5A219 307	5473029021	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.00	Electrical	Electrical	Apartment			06/14/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	08/29/2012 12:00:00 AM	ADDRESS	34.12468	-118.2211	FIre alarm. One panel replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22239	18041-20001-15729	12991 W BLAIRWOOD DR	91604	2	162B161   344	2385017004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Issued	01/21/2020 12:00:00 AM	ADDRESS	34.14182	-118.41689	Revisions to approved set and expansion of permit scope - new 40.5 kWh energy storage system and associated distribution added to permit scope alongside 26.25 kW DC / 23.862 kW AC roof mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22240	11041-10000-08470	555 S FLOWER ST 8TH FLOOR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			Plans on Hold	06/01/2011 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI IN AN OFFICE BLDG. EPC IS FOR POWER & ENERGY. (8TH FLOOR OF A HIGHRISE BLDG)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22241	11041-10001-09795	2101 E PACIFIC COAST HWY Substation-#10	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Issued	08/18/2011 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALL A 7.5MVA, 13.8KV:2.4KV STEP DOWN TRANSFORMER IN SUBSTATION #10 FOR TWO CRUDE OIL PUMP MOTORS (250HP & 1,250HP) IN TESORO REFINARY.   <<<<<<<<INSTALL APPROX. 1100' OF OVER HEAD 13.8KV LINES FROM THE MAIN SUBSTATION AND CONTINUES WITH APPROX 500' OF SAME 13.8KV LINES IN A CABLE TRAY TO SUBSTATION #10.  11041-10000-0979>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22242	13041-20002-16949	7528 N KRAFT AVE	91605	6	186B169   384	2316010026	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.20742	-118.38001	Modifications to approved set.  Modules on detached garage rooftop removed.  (((PV-1 Plan check for 11.5KW roof mounted photovoltaic system. Ungrounded system using Power-One inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22243	14041-10000-05157	11100 W SANTA MONICA BLVD SUITE 725	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI IN AN EXISTING HIGH RISE BUILDING TENANT SPACE, TOTAL  AREA 3282 SQ FT.  PLAN CHECK FOR TITLE 24 FOR CHANGES TO LIGHTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22244	19041-20000-00478	10608 N MARKLEIN AVE	91345	7	207B145   438	2649012009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Issued	01/07/2019 12:00:00 AM	ADDRESS	34.26298	-118.47003	Plan check for PV roof mounted system, system size: 5.51KW DC, 4.6kW AC with 19 PV Modules and 1 inverter(4.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22245	16041-30000-11810	4240 N LAUREL CANYON BLVD	91604	2	165B165  1295	2368015070	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.14736	-118.39624	Installation of fire alarm system in new 4 story 32 unit apartment building.  Total system size = 139 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22246	14041-10000-29428	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Title 24 plan check only.  Total area = 38,400 sq. ft. (outdoor)Installation of new pole lighting for an outdoor parking lot.  One new 400 A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22247	18041-10000-34899	555 W 5TH ST #3350	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI TO AN EXISITING OFFICE SPACE NEW LUKMINAIRES AND CIRCUITSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22248	15041-10000-41317	13266 N MISSION TIERRA WAY	91344	12	225B133   173	2601010023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Closed	12/31/2015 12:00:00 AM	ADDRESS	34.31117	-118.50281	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 57.6KWac. (31)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22249	19041-10000-37437	423 S WESTERN AVE	90020	10	135B193   530	5503015022	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2117.03	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM			PC Info Complete	09/18/2019 12:00:00 AM	ADDRESS	34.06637	-118.3093	T-24 PLAN CHECK FOR A TI TO A AN EXISTING SPACE GENERAL LIGHTING. CORE AND SHELL FOR FUTURE TENANT. (NOT FIRST TIME TENANT). SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFFECTED AREA IS 7204 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22250	19041-10000-14714	119 S HOBART BLVD	90004	10	138B193  1030	5517012031	R1-1	Central	Wilshire	Wilshire Center-Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM			PC Info Complete	06/27/2019 12:00:00 AM	ADDRESS	34.07317	-118.30563	Adding a battery system (Tesla Powerwall) to an exisiting PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22251	16041-10000-01122	1989 N PHILLIPS WAY	90042	14	159A225   179	5479019062	RE11-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/13/2016 12:00:00 AM	PIN	34.12851583	-118.20114646	PV1, rooftop solar installation, (13) MODULES, (1) PVI-3.0-OUTD, interconnect with 100MSA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22252	18041-10000-17844	7441 N CANOGA AVE	91303	3	186B105   466	2111006007	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.20582	-118.59767	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22253	19041-10000-06626	1507-1541 S MIRASOL ST	90023	14	117A227    49	5192005008	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Issued	10/02/2019 12:00:00 AM	ADDRESS	34.0156	-118.19961	NEW NURSSERY (PLANT) CULTIVATION EXRACTION LAB AND COMMERCIAL BAKERY. 4 @ 277/480V SERVICES, 72,382 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22254	16041-20000-13165	201 N FIGUEROA ST 8TH FLR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for Title 24 only. Project site is the 8th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,301 sq. ft.Note: Building permit has been pulled under 16016-10000-04850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22255	15041-20001-03861	115 N CANYON VIEW DR	90049	11	132B141   502	4405015007	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2015 12:00:00 AM			PC Approved	02/25/2015 12:00:00 AM	ADDRESS	34.05769	-118.48432	EXPEDITEPV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING TRANSFORMERLESS INVERTER. USING NONSTANDARD PLAN. TOTAL OF 45 MODULES. INTERCONNECT WITH 400A MSP. SYSTEM USES A COMBINER BOX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22256	15041-20001-43876	543 W 121ST ST	90044	15	084B201  1267	6117003014	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM			PC Approved	01/02/2016 12:00:00 AM	ADDRESS	33.92262	-118.28453	Expedite per applicantPV1, rooftop solar installation interconnect with 400A MSP(44) Q.PRO BFR-G4(44) M215-60-2LL(1) 125A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22257	16041-20001-20526	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.09782	-118.31646	(12/6/2016)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 25a.  (((Plan check power and eneregy 1st time tenant  in 14 story building Netflex occupy 1st-2nd floor and 5th-14th floor. Total area: 237,039 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22258	11041-20000-24401	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	Existing fire alarm for medical building.  Upgrading the existing fire alarm panel and adding new devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22259	17041-10000-26177	753 N LILLIAN WAY 1-8	90038	13	141B185   304	5533032023	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.08495	-118.32792	PLAN CHECK FOR FIRE ALARM SYSTEM FOR 3 STORY 8 UNIT APPARTMENT - PLAN CHECK INCLUDES 1 FIRE ALARM PANEL WITH 26 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22260	17041-20000-17022	23 E WINDWARD AVE	90291	11	106-5A143  30	4226008014	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Expired	06/23/2020 12:00:00 AM	ADDRESS	33.98732	-118.47327	"Plan check for energy only. TI to existing restaurant. New lighting. 2,731sqft. ""COMPLY WITH DEPARTMENT ORDER effective date 05/15/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22261	17041-10000-06244	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Info Complete	03/31/2017 12:00:00 AM	ADDRESS	33.78734	-118.29768	PC FOR FUEL CELL SYSTEM. USING 210KW ENERGY SERVER. MAKING LOAD SIDE CONNECTION.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22262	18041-20002-38403	9524 N SHOSHONE AVE	91325	12	201B129   410	2755009011	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			PC Approved	02/26/2019 12:00:00 AM	ADDRESS	34.24414	-118.5176	2/26/2019changes ro an approved set of plans.  changes to reflect field conditions. changes noted delta C.this is plan check only.  pv1install roof mounted pv system sized 10.3KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22263	13041-10001-17898	26640 S WESTERN AVE STE C	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	09/04/2013 12:00:00 AM	ADDRESS	33.78015	-118.30862	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION # 13041-100000-17898. EXPRESS PERMIT UNDER APPLICATION 13041-10000-2285. CHANGES MADE TO FIXTURE TYPE AND COUNTS. **********************************************************************13041-10000-17898 DESCRIPTION: permit to be pulled at EPC counter only. PC for energy only. TI TO EXISTING VET. 1 story. less than 400A per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22264	13041-10001-16950	20903 W VENTURA BLVD	91367	3	171B109    76	2167001015	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	PIN	34.16677631	-118.58862304	][][TITLE 24 PART 6 ENERGY; CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGES IS FOR LIGHTING REMODEL ; ADDING 2 NEW CKTS #A-26, #A-28][][]PC AND PERMIT FOR TITLE 24 PART 6 ENERGY. less than 400A per applicant. TI existing - DRIVE THROUGH COFFEE SHOP <STARBUCKS>. has emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22265	13041-20000-19448	5037 N MURIETTA AVE	91423	4	171B153   694	2269009007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	34.16248	-118.4391	PV1 TRANSFORMERLESS INVERTER. 12 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE: 2.8 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22266	14041-10000-35668	7083 W HOLLYWOOD BLVD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/26/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.10173	-118.34439	New fire alarm system with (135) devices, (2) power supplies and (1) fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22267	18041-20000-01169	2673 N ABERDEEN AVE	90027	4	153B197    51	5588029028	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Expired	09/20/2023 12:00:00 AM	ADDRESS	34.11698	-118.29063	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (4) Tesla PowerWalls to an existing solar PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22268	19041-20000-13871	3022 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22269	14041-10003-07239	11985 W BLUFF CREEK DR BLDG 3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	((((5/4/2015))))CHANGES TO AN APPROVED SET OF PLANS.  ADDING 29 SENSORS PER PAGE MG 2.00.METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35606.BLDG PERMIT: 13010-10000-04244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22270	12041-10000-24769	7703 W MELROSE AVE	90046	5	141B177   549	5527008028	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.08389	-118.35765	Revision to approved plans. Adding exterior light fixtures and revise emergency lighting circuit. #11041-10000-26842, #11041-10001-26842	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22271	18041-10000-11942	2035 N HIGHLAND AVE	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.10759	-118.3376	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22272	18041-20000-14257	10801 N BOTHWELL ROAD	91311	12	207B117   127	2708011014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.26622	-118.56152	Plan check for a PV1 roof-mounted PV system. System size is 9.74 kW CEC-AC and 10.5 kWdc and consists of (1) inverter and (30) modules. Inverter power output is 7.6 kWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22273	14041-20000-33534	18846 W KILLOCH WAY	91326	12	216B121   170	2820015023	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.29117	-118.54391	PV1 SFD. TOTAL SYSTEM SIZE 6.48KW AC USING 24 MODULES. USING MICROINVERTER SYSTEM. ENPHASE M250.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22274	13041-20000-19622	1477 W SUNSET BLVD	90026	13	139-5A209 273	5406001015	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.0757	-118.2544	NEW 600A SERVICE FOR MULTI TENANT BUILDING. LOAD CALC FOR FUTURE TENANT, REPLACE EXISTING PANEL  AND RECONNECT EXISTING LOADS. PC FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22275	15041-10000-05562	21200 W SUPERIOR ST	91311	12	201B105   195	2746006008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.24624	-118.59441	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 15596 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22276	13041-10000-15329	823 N SEWARD ST	90038	4	141B185   144	5533024029	[Q]MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.08594	-118.33326	PLAN CHECK POWER AND ENERGY FOR INTERIOR T.I. 2-STORY COMMERCIAL BUILDING. LOCATION IN METHANE BUFFER ZONE. NO METHANE MITIGATION REQUIRED PER METHANE REPORT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22277	15041-10001-34687	717 N ARAGON AVE	90065	1	145-5A219 333	5453027005	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	34.09169	-118.22154	EXPEDITE PER CUSTOMER REQUEST.PV1.  Installation of 2.12 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22278	16041-20000-44968	418 N NORTH FARING ROAD	90077	5	141B153    46	4358007015	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			Reviewed by Supervisor	01/25/2017 12:00:00 AM	ADDRESS	34.08616	-118.43257	POTABLE WATER, WASTE/VENT, GAS FOR (N) Two story  accessory living quarter at southeast side of the property(Accessory Building#5) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22279	18041-20001-29979	11754 W SAN VICENTE BLVD	90049	11	129B145    93	4265018017	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM			PC Approved	11/09/2018 12:00:00 AM	ADDRESS	34.05289	-118.46792	Revision to approved set of plans.  Lighting revisions. (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to a restaurant. Total lighting area = 1,925 sq. ft.Note: Building application has been generated under 18016-10000-23338)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22280	16041-10000-43122	9861 N DE SOTO AVE	91311	12	201B109   122	2746002001	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.2494	-118.58881	PC for energy only. Remove HID fixture and replace with new LED fixture. Total area: 24,175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22281	13041-10000-32234	15355 W SHERMAN WAY SUITE A	91406	6	183B145    43	2222027039	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.20139	-118.46803	TITLE 24 PART 6 ENERGY FOR (E) RESTAURANT (STARBUCKS). EXISTING PANELS AND CKTS. SCOPE OF WORK IS < 400A. EMERGENCY FIXTURES ARE EXISTING & IS NOT IN SCOPE OF WORK.NO CHANGE IN PARKING AND NO NEW FLOOR AREA. e-permit to be pulled  @ electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22282	11041-10000-00760	19161 S HARBORGATE WAY	90501	15	060B193   442	7351021044	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	33.85627	-118.30374	T.I. NEW OFFICES 720 FI SQ. IN AN EXISTING WAREHOUSE. EPC IS FOR T24 & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22283	11041-10000-25518	7800 N HASKELL AVE	91406	6	189B141   209	2206001020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.21241	-118.47476	Plan check for new water flow monitoring system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22284	19041-20000-29758	6363 W WILSHIRE BLVD ste 520	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.06385	-118.3674	ti to an existing commercial building.  adding new lighting new controls to existing panel. plan check for indoor energy only. high rise building. medical office, consultation only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22285	19041-10000-15077	20159 W RINALDI ST 120 BLDG 5	91326	12	210B113   290	2701100007		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.27528	-118.57287	FULL PC PWR AND ENERGY FOR TI (FIRST TIME USE). EXISTING SERVICE IS 600A, 480/277V, 3PH, 4W. SCOPE OF WORK AREA 2,465SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22286	13041-10000-26029	10951 W PICO BLVD 3RD FLR	90064	5	126B157  1085	4322009017	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.039	-118.43124	TITLE 24 PLAN CHECK ONLY. EMERGENCY LIGHTING. PERMIT WAS PREVIOUSLY PULLED AT 13041-30000-25411. OFFICE BUILDING, 4 STORIES. WORK IS ON 3RD AND 4TH FLOOR.REPLACE 70 INCANDESCENT LIGHTS WITH FLUORESCENT DOWNLIGHT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22287	13041-20000-00307	6550 N ODESSA AVE Snak Shack	91406	6	180B137   319	2233033907	[Q]A1-1XL	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.1901	-118.49001	Alteration of existing building from storage to kitchen and storage.  Installing lighting and electrical outlets.  Plan checked for T-24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22288	13041-10000-02082	946 E 12TH ST	90021	14	123A211   196	5132013009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM			PC Approved	05/03/2013 12:00:00 AM	ADDRESS	34.03135	-118.24843	SINGLE STORY BUILDING.  3 RETAIL UNITS.  T24 INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22289	18041-20001-25223	6313 W RIGGS PL	90045	11	102B165    89	4110013014	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM			PC Approved	07/26/2018 12:00:00 AM	ADDRESS	33.9779	-118.39671	Expedite per applicant request. Plan check for PV roof mounted system, system size: 11.4kW with 41 modules and 1 inverter(11.4kW) connected to 600A  Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22290	14041-10001-33857	907 E 3RD ST	90012	14	129A215   266	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Closed	10/08/2015 12:00:00 AM	PIN	34.0461867	-118.23487077	Changes made to previoslye  approved set ,  addition of two new panels , change of two feeders and other delta 3           due to finacial obligation  going back to old existing main sevice and switch gear.Plan check for power only. Any future improvements or buildouts to have separate permits. Scope of project includes Removal of (E) distribution equipment and installation of New service and distribution equipment: 1 for 1 1200A 3p3w service replacement (MSB); Transformers (T-A,B,C,D,E); distribution board (LA1), panels  (HA-3,4,5,6) and underground conduit stub-outs to be installed. No loads in scope of this phase of project except Temp power circuits for construction.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22291	17041-10000-35605	6433 W WARNER DR	90048	5	135B173   907	5088013015	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	08/03/2019 12:00:00 AM	ADDRESS	34.06293	-118.36939	PC for two energy storage systems in SFD with existing PV and load center.Total energy storage capacity is 27kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22292	19041-20000-02451	2282 N MANDEVILLE CANYON ROAD	90049	11	138B133   487	4493004011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.0772	-118.50001	Plan check for a PV1 roof-mounted PV system. System size is 19.9 kWdc/19.1 kWac-CEC and consists of (2) inverters, (56) modules, (1) load center, and (1) battery back-up unit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22293	19041-20000-32222	806 E 3RD ST UNIT #130	90013	14	129A215   316	5163015028	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.04564	-118.23594	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 1000 sq ft. B#19016-10000-23029	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22294	14041-10000-04016	6670 W HOLLYWOOD BLVD	90028	13	148-5A185 140	5547014014	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.10133	-118.33587	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22295	12041-10000-17838	3550 W WILSHIRE BLVD STE.#1750	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.06157	-118.30226	Change to lighting and receptacles, moving interior walls in an existing high-rise office building.  Load is less than 400 Amps per applicant, may require full plan check based on field inspection.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22296	18041-20000-19667	1405 S MENLO AVE	90006	1	129B197  1290	5056001011	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.04606	-118.29061	Plan check for PV installed 1 PV module to existing system 5.0kW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22297	18041-10000-16546	8500 W BEVERLY BLVD #665	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Issued	07/02/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR ENERGY ONLY TO A TI, EXISTING RETAIL SPACE WITHIN BEVERLY CENTER MALL. SCOPE INCLUDE NEW PANELS, EQUIPMENTS CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1826 SQ.FT. B#18016-10000-13567	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22298	15041-20000-20544	4597 N WHITE OAK PL	91316	5	168B129   635	2182018010	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Expired	07/26/2017 12:00:00 AM	ADDRESS	34.15412	-118.5221	Plan check for PV roof mounted system. System size: 8.0kW with21 inveters(5.0kW and 3.0kW) and 37 modules. Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22299	10041-10001-02167	300 E WATER ST	90744	15	027B209   227	7440010***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Info Complete	06/15/2011 12:00:00 AM	ADDRESS	33.76636	-118.25616	"REVISED SINGLE LINE DIAGRAM- ADDING AN OPTIONAL STANDBY GENERATOR AND ATS  TO SUPPLY THE SWBD ""POL"" WHEN POWER FROM SWBD "" PR"" IS INTERRUPTED. Plan check for power new electrical system.  Electrical system to power prefab. modular buildings and to floating dock."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22300	11041-20000-05210	11611 W SAN VICENTE BLVD 8TH FLR-RESTROOMS	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	03/16/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTROOMS ON THE 8TH FLOOR. EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22301	16041-20000-32211	1605 N CAHUENGA BLVD	90028	13	148-5A187 315	5546007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Issued	09/12/2016 12:00:00 AM	ADDRESS	34.09994	-118.32968	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS, NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR TILE 24 AND EM LIGHITNG. TOTAL SQUARE FOOTAGE  2511.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22302	16041-20000-08962	19338 W LEMAY ST	91335	3	180B117   406	2131006002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.19127	-118.55493	Install a roof-mounted solar array on a SFD. New 3kW ungrounded system is an addition to an existing 5kW system on the roof. Interconnecting with a 200A MSP, derating the main to 175A. (9) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22303	18041-20000-00176	9011 N MARIBEL WAY	91326	12	216B109   171	2701081020	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Closed	04/18/2018 12:00:00 AM	PIN	34.29075763	-118.58243189	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consists of (15) PV AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22304	19041-10000-18028	12621 N ENCINITAS AVE	91342	7	219B141    71	2604035027	[Q]CM-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.29948	-118.47357	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22305	16041-20001-09662	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	Approved plans lost - recheck/validation based on issued correction list.  (((Plan check for power and energy. Project site is a tenant space within a new grocery store. Tenant space will be used as a restaurant. Total lighting area = 1,588 sq. ft.Note: Building application has been generated under 16016-30000-05508)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22306	18041-10000-42151	6245 W WILSHIRE BLVD 101	90048	5	135B177   481	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.06356	-118.36478	FIRST TIME TENANT, NEW RESTAURANT IN A SHELL SPACE ON THE 1ST FLOOR OF A HIGH RISE BUILDING. PLAN CHECK FOR POWER & ENERGY. BULDING PERMIT: 18016-10000-35472	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22307	18041-20001-00327	7453 N VANALDEN AVE	91335	3	186B121   462	2104020015	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.2063	-118.54929	EXPEDITED PER APPLICANTS REQUEST.ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.9KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22308	13041-10000-05871	652 E 90TH ST	90002	9	094-5A207  69	6042012016	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	33.95459	-118.26333	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 1.7 KW. 8 PANELS AND MICROINVERTERS. [MICROINVERTER: ENPHASE M215-60-2LL-S2X] [SOLAR  MODULE: YINGLI YL245P-29B].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22309	12041-10001-23427	5250 N LANKERSHIM BLVD #700&710	91601	4	171B173   367	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.16668	-118.37545	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T.I. UNIT #700&710. ADDITIONAL PERMIT FOR LIGHTING AND EXIT SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22310	14041-10000-09670	811 W WILSHIRE BLVD	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Issued	04/11/2014 12:00:00 AM	ADDRESS	34.04973	-118.2584	permit to be pulled at EPC counter only. Plan check for energy only. high rise Emergency lighting from panel 1LE. TI TO RESTROOM ON 4TH FLOOR OF A HIGHRISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22311	11041-10000-26131	3222 S GRAND VIEW BLVD	90066	11	117B153   700	4248014033	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2011 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	01/17/2012 12:00:00 AM	ADDRESS	34.01625	-118.44081	New 4.6kw rooftop photovoltaic system for a single family residence.  3 strings and one inverter.  Applicant says they will change the inverter type from what is on the drawings. (NOTE: The proposed inverter is manufactured by Power-One, Model PVI-4.2-OUTD-S-US (240V) for transformerless operation.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22312	13041-10000-25994	5570 S LINCOLN BLVD	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	33.97271	-118.43031	NEW FA FOR LA FITNESS. SCOPE OF work [60 devices]: 1. remove existing fire alarm control pnale (notifier AFP-200) 2. add 1 fire alarm control panel and graphic annunciator at 1st floor tenant improvement (LA FITNESS.  )3. add monitor modules to reconnect all existing waterflow and valve tampers4. add manual fire alarm boxes and notification appliances (horn/visuals) at LA fitness tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22313	12041-10000-05198	770 W WILSHIRE BLVD 4th floor	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	06/15/2012 12:00:00 AM	ADDRESS	34.04914	-118.25811	Tenant improvement. Commercial high-rise building. 12,000 sqft of 4th floor. Energy and emergency lighting only.        PLAN CHECK MAY BE REQUESTED AFTER INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22314	13041-10000-21335	12505 W SHELDON ST	91352	6	195B165   332	2634006904	(T)(Q)RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.23089	-118.40556	TITLE 24 PLAN CHECK FOR OUTDOOR LIGHTING ONLY. 22,942 SQFT. SERVICE IS 200 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22315	12041-20000-23957	9911 W PICO BLVD	90035	5	129B165    65	4330005043	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.05339	-118.40441	TITLE 24 HIGH RISE. REMODEL. 2067 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22316	14041-20000-05807	18043 W DELANO ST	91335	5	177B125   335	2123023096	R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	PIN	34.1832166	-118.52622354	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.3KW AC USING 20 MODULES. USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22317	16041-10000-21766	906 N LAS PULGAS ROAD	90272	11	129B121   338	4420010027	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.0505	-118.53859	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(21)MODULES-SOLARWORLD SW 285(1)INVERTER-SMA AMERICA SB6000TL-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22318	14041-20001-00510	10123 N WISH AVE	91325	12	204B133   386	2694004015	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.25482	-118.50795	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 9KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22319	16041-10001-07754	430 N SALTAIR AVE	90049	11	135B141    21	4402003009	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.07008	-118.47501	Revisions to approved set of plans. Chnges to reflect what is installed in the field per inspector. Single family.Note*Change of engineers from original plans. Authorization Letter has not yet been provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22320	18041-20000-46601	4718 W FRANKLIN AVE	90027	4	150B197   871	5589028007	R3-1	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM			Reviewed by Supervisor	01/18/2019 12:00:00 AM	ADDRESS	34.10525	-118.29251	Plan check for multi residential building 6 units  3 story with 800A Service. Total area: 10,666 sq ft.  B#18010-10000-01786	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22321	18041-10000-09031	8322 N BALBOA BLVD	91325	12	192B133   230	2205001010	M2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Issued	03/13/2018 12:00:00 AM	ADDRESS	34.22182	-118.50246	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22322	15041-10000-25917	301 S RIMPAU BLVD	90020	4	135B185   104	5505004007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.06859	-118.3305	"""0$ permit fees due to senate bill 1222""PV1 ROOF MOUNTED SYSTEM FOR A SINGLE FAMILY HOME. (2) INVERTERS 13KW, (56) MODULES , INTERCONNECTED WITH THE MAIN SERVICE PANEL."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22323	14041-20000-10556	4741 N SAN SEBASTIAN DR	91364	3	168B097   617	2076011022	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Expired	05/24/2016 12:00:00 AM	ADDRESS	34.15481	-118.61981	Roof mounted PV system with 8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22324	17041-20004-11832	17075 W DEVONSHIRE ST	91325	12	204B133   139	2695020031	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	ADDRESS	34.2577	-118.50483	Revision to approved set of plans.  Changes to equipment locations.  PV system now interconnects at 2 different bus sections on main service.  (((Plan check only for review of lost set of plans.)))  (((PV2.  Install roof-mounted PV system sized 57.6kW interconnected with MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22325	11041-20000-19751	127 S SAN VICENTE BLVD Bulletin-94CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta # 94CS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22326	19041-20000-41059	11881 W TERRA VISTA WAY #113	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22327	19041-10000-38614	4717 N LAUREL CANYON BLVD	91607	2	168B165   673	2356037038	[Q]C2-1VL-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.1562	-118.39668	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22328	11041-10000-19777	8365 W 3RD ST 6th floor	90048	5	138B173   758	5511015017	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.07307	-118.37236	Non human operatory rooms on the sixth floor of the Davis Building.  Plan check for power, emergency lighting, and T24 lighting compliance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22329	17041-10000-11330	14401 W SATICOY ST	91405	2	186B149     7	2215001910	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Issued	06/30/2017 12:00:00 AM	ADDRESS	34.20855	-118.4479	Installation of a new PV2 commercial system. 300KW solar carport system, 1053 solar modules, and (4) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22330	12041-20000-18135	9700 N WOODLEY AVE	91343	12	201B141   287	2671001903	PF-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West	YES	1172.02	Electrical	Electrical	Apartment			08/02/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Expired	10/28/2014 12:00:00 AM	ADDRESS	34.24656	-118.48475	New fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22331	19041-10000-21604	10725 W PENROSE ST	91352	7	195B177   105	2544027013	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.23242	-118.36499	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22332	12041-20000-22195	6651 N FALLBROOK AVE	91307	3	180B097   183	2038040013	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Closed	07/05/2013 12:00:00 AM	ADDRESS	34.1915	-118.62498	50,644 SF Health Club.  New 1600 Amp swb, circuits, and lighting.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22333	17041-20000-40667	517 N HARVARD BLVD	90004	13	141B193  1151	5521011024	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.0805	-118.30471	Plan check for a fire alarm system for a 2-story apartment building. Fire alarm consists of (1) FACP and (21) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22334	13041-10000-04062	657 W REDONDO BEACH BLVD 1-6	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM			PC Approved	02/15/2013 12:00:00 AM	ADDRESS	33.89279	-118.28709	T24 FOR A PANDA EXPRESS RESTAURANT.  PERMIT TO BE ISSUED AT PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22335	19041-10000-41262	8022 N LLOYD AVE	91605	2	189B157   285	2304021018	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.21666	-118.42057	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) AND 10 PANELS USING P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22336	14041-10000-08895	7080 W HOLLYWOOD BLVD # 102	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.10134	-118.34445	TI FOR CHANGE OF USE FROM OFFICE TO CLASSROOM. TOTAL NEW LOAD DOES NOT EXCEED 400AMPS. PLAN CHECK FOR ENERGY ONLY. BUILDING APPLICATION#: 14016-10000-04989	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22337	16041-20001-35489	6600 N TOPANGA CANYON BLVD SPACE 2016	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM			PC Approved	03/24/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	3.24.2017 - Plan check for changes to approved set. Lighting plan updated, recheck T24 compliance forms to reflected changes. Changes clouded delta 4.======T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL RETIAL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1979 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22338	13041-10000-10048	5115 W WILSHIRE BLVD UNIT G	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.06233	-118.34134	THE PC # IS VALID FOR BOTH PLAN CHECK AND PERMIT.PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT COFFEE BEAN. 2007 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22339	11041-20000-18720	6707 N BIANCA AVE	91406	12	180B129   182	2229010095	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.19237	-118.51323	Plan check new roof mounted 9.03KW photovoltaic system single family dwelling. Permit includes service panel upgrade to 225A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22340	12041-10000-10167	6753 W HOLLYWOOD BLVD part   A	90028	13	148-5A185  97	5547011015	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.10172	-118.33758	title 24 and emergency lighting, 7 stories not a high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22341	17041-20000-15810	740 N FAIRFAX AVE	90036	5	141B177   360	5527011001	C2-1VL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	PIN	34.08500272	-118.36111231	TI to (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22342	19041-30000-05823	941 S FEDORA ST	90006	10	132B197  1034	5094022036	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2123.05	Electrical	Electrical	Apartment			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.05469	-118.29779	Plan check for a fire alarm system for a 4-story apartment building. Fire alarm system consists of (1) FACP and (51) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22343	17041-10000-32236	633 W 5TH ST 14th flr	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	T-24, Full floor TI on the 14th floor of an existing office building to include scope of work inlcudes new lighting and power circuits. Total sq. ft. 19740.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22344	12041-20000-27273	17071 W VENTURA BLVD #104	91316	5	168B133    26	2258013014	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			Corrections Issued	11/14/2012 12:00:00 AM	ADDRESS	34.16043	-118.50532	Change of lighting to an existing 2-story commercial office space.  Load is less tha 400 amps, per applicant.  PLAN CHECK ONLY FOR ENERGY,  NO Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22345	14041-20000-13603	22234 W MARLIN PL	91303	3	183B101   477	2024035020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.19669	-118.61158	PV1.  Install 864 W roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22346	18041-20000-35964	6320 N CANOGA AVE Ste 1700	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Issued	09/20/2018 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check for Title 24 only. Project site is a suite in an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 13,379 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22347	17041-10000-14856	1871 W COLORADO BLVD	90041	14	162A223    93	5669025026	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.13948	-118.20829	Title 24 plan check.  Addition of new retail area to existing commercial building.  New 100 amp subpanel with lights and receptacles.  Total area = 785 sq. ft.     Building permit #15014-10000-02358	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22348	17041-20001-15418	4847 W OAKWOOD AVE	90004	4	138B193   216	5522030003	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			03/29/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.0774	-118.31305	plan check only, changes to approved set. replacement of power packs with line voltage occupancy sensors, minor changes to T24 lighting control section and floor plans. clouded changes only*original*PC FOR POWER AND ENERGY FOR A 4-STORY, AND 49-UNIT APARTMENT. SCOPE INCLUDES (12) TYPICAL UNITS; SERVICE RATED AT 120/208V, 3-PHASE1600 AMP.  B# 16010-20000-03296	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22349	12041-10000-10787	1153 S CRENSHAW BLVD	90019	10	129B189   428	5082025027	R3-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.0513	-118.32509	TI IN AN EXISTING OFFICE BUILDING.   PLAN CHECK FOR ENERGY ONLY.  PERMIT FOR NEW CIRCUITS IN AN EXISTING PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22350	13041-20000-24948	17231 W SHERMAN WAY	91406	6	183B133     8	2227016044	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.20136	-118.50861	T24 FOR EXISTING CHURCH SCHOOL. THIS PLAN CHECK COVERS REPLACEMENT OF LIGHTS ONLY. TOTAL SQRFT 4250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22351	19041-10000-22209	10943 N HERRICK AVE	91331	7	210B161   718	2534024905	OS-1XL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.26922	-118.41302	"TI IN AN EXISTING COMMERCIAL AREA. REPLACING EXISTING LIGHTS WITH NEW ""LED"" LIGHTS.T-24 ENERGY ONLY. AREA: 14,000 SQR FT."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22352	15041-10001-00270	20301 W ANGELINA PL	91364	3	171B113   222	2166036006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2015 12:00:00 AM			PC Approved	01/14/2015 12:00:00 AM	ADDRESS	34.16531	-118.57714	Supplemental application for expedite fees - Installation of new roof mounted solar PV system.  2 inverters with 36 modules (4 strings) with new main service panel.  Total system size = 9 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22353	19041-30000-45824	2049 S CENTURY PARK EAST #620	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Energy plan check only. Area of scope 2374 Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22354	19041-10000-53003	10654 N IRMA AVE	91042	7	207A195   134	2557024900	OS-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Info Complete	12/23/2019 12:00:00 AM	ADDRESS	34.26298	-118.30066	T-24 ENERGY ONLY PLAN CHECK FOR NEW TI TO EXISTING POOL RECREATIONAL CENTER. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 5573SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22355	15041-10001-24122	1730 W MANCHESTER AVE	90047	8	097-5A193 336	6037014024	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Info Complete	03/28/2017 12:00:00 AM	ADDRESS	33.9598	-118.3078	"01/31/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER ""PC-1"", ""PC-2"", AND ""PC-3"". CHANGES INCLUDE ADDING NEW PANELS, NEW CIRCUITS, REVISING LOAD CALCULATIONS, REPLACING FLOURESCENT LIGHTING FIXTURES WITH LEDS, AND REVISIG TITLE 24 CALCULATIONS. NEW TOTAL AFFECTED AREA IS 25139.6 SQ. FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22356	14041-20000-34079	5256 N ELLENWOOD PL	90041	14	163-5A221 141	5671019017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Apartment			12/09/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Expired	01/18/2017 12:00:00 AM	ADDRESS	34.14259	-118.218	PV1 roof mounted with system size: 3.8kW and 1 inverter and 17 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22357	14041-10001-06919	1028 S WESTWOOD BLVD	90024	5	132B153    38	4363020008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	ADDRESS	34.06195	-118.44516	Change approved 2 meter sections to a single meter section ONLY.Plan check only. Supplemental application to permit #14041-10000-06919.[[[T.I. to a retail space with new panels and circuits.  Plan check for POWER and Energy, per applicant request. (original Plan expired #11041-10000-23363)]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22358	18041-20000-00368	2122 S GUTHRIE DR	90034	5	126B165   196	4309015024	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.04378	-118.3943	PV1. ROOFMOUNTED SOLAR SYSTEM ON STAND ALONE GARAGE WITH LIMITED SETBACKS. SYSTEM SIZE: 5KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22359	13041-20000-33963	7823 W WOODROW WILSON DR	90046	4	156B173   376	5570022021	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.123	-118.36668	SOLAR 4.16 KW SINGLE FAMILY	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22360	11041-10000-24713	818 W 7TH ST Ste 510	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM			PC Approved	12/01/2011 12:00:00 AM	ADDRESS	34.04895	-118.25943	T.I. to an existing office building on the 5th floor.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22361	14041-20000-20539	17183 W OSBORNE ST	91325	12	195B133    93	2690002017	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Expired	09/05/2016 12:00:00 AM	ADDRESS	34.23351	-118.50845	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 12 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING 59 MODULES. USING OPWER OPTIMIZERS.$0 permit fee is due to Senate Bill SB-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22362	16041-10001-44039	1096 N WESTERN AVE 1D , 1E	90029	13	144B193   795	5536023022	C2-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Approved	07/13/2017 12:00:00 AM	ADDRESS	34.09041	-118.30895	PC PER INSPECTION TO INCLUDE PHOTOSENSORS AND DAYLIGHT ZONES ON THE PLAN. REVISE T-24 FORMS TO INCLUDE CONTROLS.PLAN CHECK ONLY!!!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22363	15041-10000-06714	1836 N DOHENY DR	90069	4	150B169  1192	5561008043	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.10553	-118.3879	$0 PERMIT FEE IS DUE TO STATE SENATE BILL SB-1222. PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.7KW INTERCONNECTED WITH MSP.(51) CANADIAN SOLAR 260W MODULES(2) SUNNY BOY TL INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22364	14041-20000-03547	3027 E FAIRMOUNT ST	90063	14	129A227    90	5178002020	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.04871	-118.19599	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22365	15041-20000-33187	4918 N LOCKHAVEN AVE	90041	14	162A219   213	5683027008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.13827	-118.22351	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (24) modules, (24) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22366	14041-10000-12011	189 S THE GROVE DR STE K90	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.07125	-118.35662	PERMIT TO BE pulled at EPC counter only. Plan check for energy. Less than 400A, emergency lighting installed.  ADD ADDITIONAL SEATING 591 SF AT BALCONY AREA AT EXISTING CHEESECAKE FACTORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22367	16041-10000-36099	13468 W BEACH AVE	90292	11	108B149  1216	4230004032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	33.99031	-118.44602	T-24, PC for energy only. Interior tenant improvement and exterior alterations to existing commercial building.  Change of use from part warehouse to Office space. Total affected area is 9825. B#16016-10001-01053	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22368	18041-10001-36877	10250 W SANTA MONICA BLVD 2930	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	SUPPLEMENTAL TO APPROVE SET OF PLAN SCOPE OF WORK INCLUDES CHANGE OF LIGHTING ENERGY METHOD FROM PERSPECTIVE TO PERFROMANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22369	11041-10000-05253	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM			PC Approved	03/17/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	T.I. TO AN EXISTING HIGH-RISE OFFICE BUILDING.  T-24 OVER THE COUNTER PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22370	19041-20002-00958	9661 W WENTWORTH ST	91040	7	207B181    32	2549004012	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.26427	-118.34278	Revisions to approved set of plans.  Service upgrade details added to plans.  (((Plan check for PV roof mounted system, sytem size: 18.58 KW DC, 15.5KW ACwith 58 PV Modules and 2 inverters(7.6kW)  connected to 400A Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22371	18041-20000-11025	10240 N COMMERCE AVE UNIT 1-36	91042	7	204B197   886	2565015119	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			03/27/2018 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	34.25531	-118.28848	Plan check for power and energy. Project site is a 3-story, 36-unit apartment building over a basement parking garage. Work includes a 1,600-amp service and a total lighting area of 26,115 sq. ft.Note: Building permit has been issued under 17010-20000-04917	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22372	18041-10000-05783	5327 1/2 S 6TH AVE	90043	8	108B189   422	5006024019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	33.99425	-118.32376	PV1. NEW SOLAR SYSTEM ON EXISTING DUPLEX BUILDING. TOTAL SYSTEM SIZE IS  2.44KWdc / 3.80kWac. Installing 8 modules with optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22373	11041-10000-14707	515 S FLOWER ST 3rd fl	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	09/09/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	remodeling of office spacesplan  chk is for title 24 and 2 ea emergency ckt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22374	12041-10001-05948	500 S VIRGIL AVE #301	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Info Complete	05/24/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	PLAN CHECK FOR DELTA 2 REVISION TO APPROVED PLANS. ADD NEW AND RELOCATE BRANCH CIRCUITS. NEW MEDICAL OFFICE SUITE #301.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22375	14041-20001-32515	4300 N STILLWELL AVE	90032	14	145-5A237  18	5309014030	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			PC Approved	01/02/2015 12:00:00 AM	ADDRESS	34.09491	-118.16354	expedite per customer request.pv1install roof mounted pv system sized 7.0kw interconnected with msp.(22) sunpower 327w modules(1) sunnyboy 7k transformerless inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22376	17041-20000-17952	12909 W MAGNOLIA BLVD	91423	4	171B161   527	2345017014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM			PC Info Complete	05/30/2017 12:00:00 AM	ADDRESS	34.16503	-118.41422	TI TO AN EXISTING COMMERCIAL BUILDING (CONVENIENCE STORE) .  ADDING NEW LIGHTING NEW CONTROLS TO EXSTING EQUIPMENT.  FACILITY TO BE OPERATED 24 HOURS A DAY.  PLAN CHECK FOR ENERGY ONLY.PERMIT FEES COVERED UNDER APPLICATION NUMBER 16041-30000-40160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22377	14041-20000-13424	5601 N DE SOTO AVE 2nd Floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.17126	-118.58861	T.I. to existhing building (Kaiser Permanente) on 2nd floor of none patience care area.  Install branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22378	13041-20000-23811	162 S ARDMORE AVE	90004	10	138B193  1215	5518002023	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.07196	-118.30152	PV1 SINGLE FAMILY DWELLING USING 21 MODULES TOTALY SYSTEM SIZE 7KW AC TRANSFORMERLESS INVERTER NONSTANDARD PLAN 3 STRINGS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22379	16041-10000-25169	8501 W PICO BLVD	90035	5	132B173  1242	4332028038	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.05355	-118.37643	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT (5,331SF) TO EXISTING BANK OF AMERICA. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5035 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22380	19041-10000-01861	1101 S HARBOR VIEW AVE	90732	15	015B193   956	7459003014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	33.73448	-118.30888	New Rooftop solar system with ESS on (E) SFD, System size at 7.6 kW AC, battery size at 9.8 kWh. Install (5) modules are installed on the main house, and (7) modules are installed on the detached garage, total (12) modules with (12) P320; (1) 7.6 kW AC inverter; (1) ESS system at 9.8 kWh; (1) 125A load center. System interconnect to (E) 200A service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22381	18041-20000-15986	8531 N FALLBROOK AVE 1st & 2nd-Floor	91304	12	192B097   582	2005022001	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.22425	-118.62931	Plan check for power and energy. Project site is the 1st and 2nd floor of an existing commercial building. Project scope is a tenant improvement. Work includes new distribution equipment and a total lighting area of 99,075 sq. ft.Note: Building application has been generated under 18016-10000-13438	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22382	15041-10000-09125	12105 W WATERFRONT DR	90094	11	105B161  1199	4211010048	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Closed	01/05/2017 12:00:00 AM	ADDRESS	33.98095	-118.40764	TEMP POWER FOR CONSTRUCTION SITE FOR 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22383	18041-10000-47846	301 S AVALON BLVD	90744	15	027B205   619	7440009911	PF-1D	Harbor	Port of Los Angeles, Wilmington - Harbor City	Wilmington		9800.31	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	09/13/2021 12:00:00 AM		Issued	09/13/2021 12:00:00 AM	ADDRESS	33.76771	-118.26109	FULL PC FOR A RECREATION PUBLIC PARK. SCOPE INCLUDE 800A , 480/277V SWITCHBOARD. PWR AND LTG. APPROX SQFT( 119,470 ). APPROX CONNECTED LOAD 565KVA ,680A. PUBLIC RESTROOM IS UNDER SEPARATE PERMIT, THIS PROJECT ONLY TO SUPPLY POWER TO PUBLIC RESTROOM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22384	15041-10000-43499	7667-7675 W BEVERLY BLVD	90036	5	138B177   424	5527041004	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.07629	-118.35699	PLAN CHECK FOR POWER CHANGE OF USE FROM RETAIL TO  TAKE OUT DELI. 800A SERVICE UPGRADE FEEDING MULTIPLE TENANT SPACES REFER TO ADDRESS FOR RANGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22385	16041-10000-37575	1750 W 39TH PL	90062	8	117B193  1591	5035015013	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.01362	-118.31277	PV1 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER. (17) MODULES AND (1) FRONIUS INVERTER. TOTAL SYSTEM SIZE IS 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22386	12041-10000-22799	330 S HOPE ST #2017	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM			PC Approved	10/04/2012 12:00:00 AM	ADDRESS	34.05319	-118.25252	T.I. to existing high rise building.  Change of use from baker to restaurant.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22387	18041-20000-14062	3303 W WILSHIRE BLVD 3th,5th-6th,7th FL	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM			PC Approved	04/17/2018 12:00:00 AM	ADDRESS	34.06195	-118.29439	Plan check for Title 24 only in existing restroom on 3rd, 5th, 6th, 7th Floor, new lighting T.I. 431 sq ft on each floor. Total area: 1,720 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22388	14041-10000-09874	915 S MATEO ST 207	90021	14	123A217   171	5166018002	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.03206	-118.23249	permit to be pulled at EPC counter only. Plan check for energy only. No emergency lighting (2 story F2 and S2 occupancy). BLDG#14016-10-02596: PROPOSED NONSTRUCTURAL INT. T.I. - 950SF. NEW BEVERAGE (JUICE) MANUFACTURING W/ ACCESSORY STORAGE/WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22389	18041-10000-08727	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.10222	-118.32701	PLAN CHECK FOR A NEW FIRE ALARMS SYSTEM CONSISTING OF 8 FIRE ALARM PANELS AND 363 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22390	16041-20000-25769	10638 W WALNUT DR	91040	7	201B177   126	2542014029	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.24983	-118.36185	"""0$ permit fee due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.68 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22391	16041-20000-10232	20600 W OAKSBORO CIR	91364	3	168A111    71	2174012027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.15477	-118.58204	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.4 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22392	11041-20000-06206	600 W WILSHIRE BLVD 880/890	90017	9	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Finaled	12/01/2011 12:00:00 AM	ADDRESS	34.04796	-118.25622	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT COMBINE TWO SUITES INTO ONE OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22393	13041-20000-11522	9453 N CREEMORE DR	91042	2	198B205   293	2572020026	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.2399	-118.27166	PV1 TWO STORY SINGLE FAMILY DWELLING. MICROINVERTER STANDARD PLAN. [MICROINVERTER: ENPHASE M215-60-2LL-S22/S23] [SOLAR MODULE: SMX 230 SOLAR PANEL]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22394	18041-10000-21974	2049 S CENTURY PARK EAST 35th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN EXISTING RESTROOMS ON THE 35TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22395	15041-10000-09067	19040 W VANOWEN ST	91335	3	180B121    25	2129021906	[Q]PF-1XL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.02	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.19368	-118.54855	PC FOR ENERGY, T24 ONLY.  CONSULTING OFFICE T.I  TOTAL AREA 5064-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22396	19041-10000-35855	1457 N VAN NESS AVE	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Issued	10/24/2019 12:00:00 AM	ADDRESS	34.09731	-118.31598	[EPLAN] PLAN CHECK FOR TITLE 24 ONLY FOR - Tenant improvement for lighting in Room 3B60 and 3B61. - TOTAL AFFECTED AREA = 552 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22397	14041-20001-22859	11028 N CAYUGA AVE	91331	7	210B153   676	2616028001	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM			Corrections Issued	08/23/2014 12:00:00 AM	ADDRESS	34.27031	-118.43393	pv system 7.25 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22398	16041-20001-31420	18137 W MARILLA ST	91325	12	201B125   252	2764018021	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.24741	-118.52893	Expedited plan check per applicant request.  (((PV1.  Install 13.68 kW roof mounted PV system.  (48) modules with microinverters and AC combiner panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22399	18041-20000-18361	18133 W VENTURA BLVD 300	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.16603	-118.52861	T.I. to (E) medical office space for oncology practice and tenant outpatient medical office. Total area: 21,294 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22400	17041-10000-11636	14801 W VENTURA BLVD	91403	4	166-5A149  18	2264017053	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.15221	-118.45548	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 18625 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22401	10041-20000-08155	5019 W HOLLYWOOD BLVD	90027	4	147B197   228	5589035002	C2-1D	Central	Hollywood	Greater Griffith Park		1892.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.10191	-118.29891	Fast food restaurant T.I. doing lighting and egress pass. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22402	12041-10000-03581	639 N BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Apartment			02/16/2012 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	PIN	34.05985996	-118.23998637	Plan check fire alarm system for new mixed-use apartment retail complex.  Chinatown Gateway Apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22403	19041-10000-17862	4515 N EAGLE ROCK BLVD	90041	14	157-5A221  80	5473037007	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	06/10/2021 12:00:00 AM	ADDRESS	34.12659	-118.219	PC FOR POWER AND ENERGY(LOT 13-19). SCOPE INCLUDES A NEW800A SERVICE FOR 7 SFD. TOTAL AFFECTED AREA IS 42218 SQ. FT. ENERGY PC UNDER MASTER 19041-10000-17858.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22404	19041-20000-41062	11881 W TERRA VISTA WAY #116	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22405	15041-10000-22260	11821 W GWYNNE LANE	90077	5	153B141   106	4378037078	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Expired	08/25/2017 12:00:00 AM	ADDRESS	34.11581	-118.47468	PV1. INSTALL 12.48 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(48) MODULES: KYOCERA KU2606CPA(2) INVERTERS: ABB PVI-5000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22406	19041-10000-40814	2121 S AVENUE OF THE STARS 24TH FL	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	10/31/2020 12:00:00 AM	ADDRESS	34.05554	-118.41342	TENANT IMPROVEMENT TO EXISTING CORRIDOR, RESTROOM, AND ELEVATOR LOBBY ON THE 24TH FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-31281	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22407	19041-10000-44054	6118 W 6TH ST	90048	8	105B189   891	4007009031		South Los Angeles				2348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.06486	-118.36209	$0 Fee due to AB1414 [EPLAN] REPLACING OLD SERVICE PANEL WITH A  NEW 200A MAIN SERVICE PANEL WITH A NEW 90A SUB BREAKER. DELTA A CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22408	15041-10000-01949	12511 W VENICE BLVD	90066	11	111B153   213	4246026007	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			Reviewed by Supervisor	02/24/2015 12:00:00 AM	ADDRESS	34.00326	-118.43497	Power and energy plan check for a dental office T.I.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22409	16041-10000-26938	12517 W CHANDLER BLVD	91607	2	171B165    19	2346011045	R1-1, RD1.5-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.1688	-118.40583	PC FOR ENERGY ONLY. REMOVE OUTDOOR HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (outdoor)14448 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22410	13041-20000-27482	14724 W VENTURA BLVD #806	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.15162	-118.45395	Existing private office remodel in spec suite.  All lights are e3xisting.  All circuits are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22411	15041-30001-06020	1900 W 6TH ST	90057	1	133-5A205 334	5142001026	C2-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.05844	-118.27287	Plan check for lost set of plans. Title 24 plan check only Total area =1,114 sq. ft.T.I. to existing restaraunt space general lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22412	18041-20000-35451	11444 W ALBATA ST	90049	11	135B145   719	4365017008	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.06314	-118.4621	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (3) Tesla PowerWalls onto an existing PV system. Service size is 400 Amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22413	17041-10001-32020	811 E TRACTION AVE UNIT 1-D	90013	14	127-5A215  36	5163015008	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.0452	-118.23546	SUPPLEMENTAL PC FOR TITLE 24 ONLY FOR  REPLACING EXISTING LIGHTS WITH NEW LED LIGHTS IN OFFICE SPACE TI. - TOTAL AFECTED AREA = 2660 SQ. FT. INSPECTION TO VERIFY LIGHTS IN CONFERENCE ROOM DO NOT EXCEED 100W PER FIXTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22414	15041-20000-10669	3526 N MARMION WAY	90065	1	144A223   355	5446025013	[T][Q]CM-1VL	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.08726	-118.21354	Plan check for power and Title-24 (energy).  Total area = 32,883 sq. ft. (conditioned) + 4,496 sq. ft. (unconditioned) + 2,589 sq. ft. (outdoor).New 4 story 49 unit apartment building with 1,600 A service.  Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22415	13041-20000-22862	8401 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.22253	-118.62558	Change to lighting and receptacles in an existing low-rise commercial building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22416	14041-10000-11077	5177 W PICO BLVD	90019	10	129B181   903	5070009034	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM			Corrections Issued	04/28/2014 12:00:00 AM	ADDRESS	34.04829	-118.35124	"PC FOR ENERGY ONLY.NEW 5,934 S.F. 1-STORY W/ MEZZANINE RETAIL BUILDING. WITH EMERGENCY LIGHTING.~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 94723  -- ElectricalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedW ith effective date 02/18/2011 by Inspector JEFFREY CHRISTIAN at phone# (213)252-3957.  CEIS Case Number is 405560.NOTE: Investigation fee is minimum $400.00 or double the permit fee which ever is greater.(Created: IMSV7 / 02-08-11)NO: 94724  -- Electrical""COMPLY WITH DEPARTMENT ORDER effective date 2/18/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  405560."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22417	13041-20001-05887	4465 N VAN NUYS BLVD	91403	2	168A151   286	2265011012	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.00, 1413.01	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.15281	-118.44889	T24 ENERGY PLAN CHECK CHANGED FROM RETAIL TO MASSAGE. 842 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22418	10041-10000-05374	701 W EXPOSITION BLVD 3rd Floor	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM			PC Approved	03/24/2010 12:00:00 AM	ADDRESS	34.01842	-118.2857	3rd floor tenant improvement,  Energy and Emergency plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22419	13041-10000-06125	250 N CAROLWOOD DR	90077	5	141B157    74	4358006013	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.08261	-118.4266	NEW CONSTRUCTION FOR SINGLE FAMILY DWELLING.   NEW 800A SERVICE AND NEW OPTIONAL EMERGENCY STANDBY GENERATOR.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22420	13041-10000-16570	11431 W KINGSLAND ST	90066	11	117B157   169	4250019001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.0194	-118.43016	PV1 4.25KW XFRMLESS. 1 STORY. NONSTD. ROOFMOUNT. (1)POWERONE PV-3.6-TL. (17)  Aleo S18U250 ULR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22421	15041-10002-00405	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Closed	10/20/2016 12:00:00 AM	ADDRESS	34.03365	-118.24048	Change to approved set by adding outdoor lighting; total scope area is 95995-SQ feet.(((NEW 10 TIER OPEN PARKING GARAGE STRUCTURE.  PARKING BUILDING TO SERVE EXISTING ADJACENT BUILDINGS ON THE SAME PROPERTY. (APPRX. 1,405,621 SF W/ 3884 PARKING STALLS))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22422	11041-10000-23749	870 W ADAMS BLVD 1-50	90007	8	123A201   189	5123002001	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.03035	-118.28166	Replacement of 50 panels in tenant units and addition of one new circuit per panel, new laundry circuits and change to lighting in common areas.  Plan check for POWER and ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22423	16041-20001-32462	1302 S PALOS VERDES ST	90731	15	012B201    52	7456012012	R3-1XL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	33.7322	-118.28124	Revisions to approved set of plans.  Optimizers were omitted from original permit application filed online.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22424	19041-10000-28527	810 E PICO BLVD 141;143;14-4	90021										Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.03119	-118.25079	NEW LIGHTING SYSTEM AND CIRCUITS IN RETAIL STORE PLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22425	11041-10001-11994	714 E TRACTION AVE	90013	14	127-5A215  41	5163012007	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	07/13/2011 12:00:00 AM	ADDRESS	34.04535	-118.23623	T.I.  Existing restaurant.  Renovation of the lighting fixtures.  Emergency lights are existing and are to remain.  There will not be any modifications done to the emergency lights.  The emergency lights are subject to field inspection.  Plan check is for energy only.<<<NEW ENERGY ONLY PLAN CHECK FOR CHANGE OF LIGHTING.  PER APPLICANT EMERGENCY LIGHT IS EXISTING & NOT PLAN CHECKED.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22426	13041-10000-23398	400 S HOPE ST #110	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.05199	-118.25366	tenant improvement for a Bakery on ground floor of highrise building per applicant.  Load is greater than 400 amps.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22427	18041-10000-48364	3620 S VERMONT AVE	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Closed	08/05/2019 12:00:00 AM	ADDRESS	34.02213	-118.29133	PLAN CHECK FOR TITLE 24 ONLY FOR TENANT IMPROVEMENT OF LAB 201 INCLUDINGNEW LAB FURNITURE AND FURNISHINGS - TOTAL AFFECTED AREA 1313SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22428	16041-30000-31134	1125 S BOYLE AVE	90023	14	123A221   272	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.03064	-118.22048	Plan check Title 24 only in existing space T.I., remove outdoor lighing fixtures and replace with new LED lighting fixtures. Total area: 20,990 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22429	14041-20001-26398	5031 N DONNA AVE	91356	3	171B121   479	2176002002	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			Corrections Issued	10/29/2014 12:00:00 AM	ADDRESS	34.16248	-118.548	Expedited plan check fee per applicant request.  PV1.  Install 7.848 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22430	18041-10000-24138	1161 E VERNON AVE	90011	9	112-5A209  25	5115034027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.00404	-118.25499	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22431	12041-10000-10122	6701 N ETON AVE	91303	3	180B105    27	2148030038	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			05/03/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.19217	-118.59564	NEW FIRE ALARM SYSTEM IN THE APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22432	18041-10001-06642	7224 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	33.97406	-118.2913	SUPPL APP FOR REPLACING EXISTING LIGHTS WITH LED IN A MARKET. T-24 ENERGY ONLY. AFFECTED AREA  14600 SQR FEET. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22433	16041-10000-04442	5340 N CANDACE PL	90041	14	163-5A229  72	5691009044	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/05/2016 12:00:00 AM	ADDRESS	34.14377	-118.19209	PV1 rooftop solar installation 6kW AC system(25) SW 285 Mono(1) SE6000A-USStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22434	10041-20000-11938	12121 W WILSHIRE BLVD 525	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	PIN	34.04391963	-118.46825257	office t.i.Energypermit is for lighting & phone wiring	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22435	18041-10000-02840	11601 W WILSHIRE BLVD 3RD FL.	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC for T24 only for new lighting in corridors and restrooms. B# 17016-20000-3519	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22436	18041-10000-04703	4640 N LANKERSHIM BLVD # 305	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.15499	-118.36841	ALTERATIONS IN OFFICES- NEW CKTS AND LUMINAIRESPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22437	13041-10001-24106	2920-2930 W ROWENA AVE BUILDING 5	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.10823	-118.26884	CHANGES MADE TO PREVIOUSLY APPROVED SET.  A) ADDITION OF PV TO EACH RESIDENTIAL UNITB) REMOVE LIGHT FROM GARAGEC) ADDITONAL J BOXES IN RESIDENTIAL UNIT FOR FANS, LIGHTS, ETC.D) REMOVE LIGHT (FL) AND REPLACE WITH INCANDESCENT WITH DIMMER IN HALLWAYS((( NEW BUILDING. APARTMENT.  1 OF 6 TOTAL UNITS. BUILDING 5. NEW 200 AMP SERVICE.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22438	19041-20000-31091	4410 S BUDLONG AVE	90037	9	111B197   141	5017017026	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Voices		2322.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.00325	-118.29574	T24 PLAN CHECK ONLY FOR LIGHT AND OUTLETS TO EXISTING SCHOOL. TOTAL SQUARE FOOTAGE =  12980 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22439	16041-20001-42706	735 W 7TH ST G-735	90017	14	129A209   265	5144029***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			PC Approved	06/13/2017 12:00:00 AM	ADDRESS	34.04867	-118.25847	Change to approved set by adding new emergency lighting. All changes under delta_1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22440	14041-10000-31664	3378 W SAN FERNANDO ROAD	90065	13	153B209   129	5458003021	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Issued	02/26/2015 12:00:00 AM	ADDRESS	34.11746	-118.25107	Energy plan check for Warehouse and office T.I. Engineer license is valid but not on our system, contractor infomation is recorded. per F.Y	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22441	14041-20000-17308	11601 W WILSHIRE BLVD 17th floor	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Issued	06/26/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	Plan check for energy only. New and relocated lighting in existing high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22442	14041-10001-00419	6544 W HOLLYWOOD BLVD	90028	13	148-5A187 185	5547015018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.10142	-118.33267	][] changes made to previously approved set of plans; changes is to reflect lighting plan ][][]T24 PART 6 ENERGY FOR (E) RETAIL 2 BUILDING STORY. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 7825 SQ FT. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22443	14041-10000-06210	3221 N LOWRY ROAD	90027	4	153A201   246	5591001026	R1-1	Central	Hollywood	Los Feliz		1882.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.11211	-118.28063	PV1, INSTALL 3.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800-US-ZB-U(15) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22444	10041-10000-19829	555 E RAMIREZ ST BSMNT	90012	14	132A217   238	5409021900	PF-1XL	Central	Central City North			2060.20	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.05425	-118.2309	OFFICE RECONFIGURATION AND INTERIOR ALTERATION  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22445	17041-10000-32133	202 N SARATOGA ST	90033	14	127-5A225 335	5180015029	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.04233	-118.20415	TITLE 24 PLAN CHECK FOR REPLACEMENT OF EXISTING (5)HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 6600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22446	18041-10000-22159	360 E 2ND ST	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	TENANT IMPROVEMENT TO FIRST FLOOR OF AN EXISTING OFFICE.  TITLE 24 ENERGY ONLY. 1426 Sqr Ft.BUILDING PERMIT # 18016-30000-18786	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22447	18041-10000-34655	2213 W SUNSET BLVD	90026	13	139-5A207  73	5402031021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1956.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.0778	-118.26566	Energy plan check for a retail T.I. Scope includes new lighting and equipment with 665-SQ FT located in a commerical building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22448	11041-20000-04661	4101 N FIGUEROA ST Bld. A and-B	90065	1	145-5A223 198	5467001047	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1994.00	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.09308	-118.20997	Fire alarm panel replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22449	16041-10000-21764	7106 S AVALON BLVD BUILD. #1	90003	9	102B205   689	6007019011	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	33.97526	-118.26498	Remove HID fixture and replace with new LED fixture. PC for T-24 only.  Total area: 37,230 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22450	17041-10000-45165	955 N EVERETT ST	90026	1	136-5A211 141	5406016017	[Q]R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Apartment			12/15/2017 12:00:00 AM			PC Info Complete	12/15/2017 12:00:00 AM	ADDRESS	34.06905	-118.24917	T-24, PC FOR ENERGY ONLY FOR AN APARTMENT GARAGE. SCOPE NEW LIGHTS FOR CORRIDORS AND GARAGE AREA. TOTAL AFFECTED AREA IS 8558 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22451	16041-10000-30466	6170 N WILBUR AVE	91335	3	177B121   336	2127014045	RA-1-K-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.18281	-118.54454	Paln check for Title 24 only remov HID fixtures and replace with new LED fixtures. Total area: 44,593 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22452	19041-20000-26616	19208 W HART ST	91335	3	183B117   595	2129009004	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.19735	-118.55173	PLAN CHECK FOR ADDITION OF A 9.8KWH ENERGY STORAGE SYSTEM TO EXISTING SFD WITH A EXISTING PV SYSTEM. SCOPE OF WORK INCLUDES A LG CHEM RESU10H BATTERY, AND A 100 BACK UP LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22453	18041-20000-01101	21550 W OXNARD ST Suite 460	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,944 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22454	17041-20000-41177	1990 S BUNDY DR Ste 375	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.03419	-118.45559	TI to (E) commercial office space in commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22455	19041-10000-50767	4606 N LANKERSHIM BLVD	91602	2	168B173   930	2421029008	C2-1VL, [Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM			PC Approved	06/16/2020 12:00:00 AM	ADDRESS	34.154	-118.3678	Energy plan check only for a car dealership, area of scope (83,863)SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22456	13041-10000-24070	15066 W SUTTON ST	91403	4	166-5A147 216	2276024003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM			Corrections Issued	09/04/2013 12:00:00 AM	ADDRESS	34.14911	-118.46214	PV1.  Install 5.25 kW DC roof-mounted solar array, interconnect with main service panel.  Solar PV Standard Electrical Plan.  Express permit obtained under 13041-20000-23283 for 21 modules and 2 inverters (2 strings per inverter) - design altered to 3 strings and 1 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22457	15041-20000-36370	7240 N CORBIN AVE BLDG 1	91335	3	186B117   912	2116001090	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Issued	11/12/2015 12:00:00 AM	ADDRESS	34.20249	-118.56208	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL APARTMENT BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 6KWac. (24) MODULES-CANADIAN SOLAR CS6P255P(1) INVERTER-SUNNY BOY SMA SB6000US-12(1) 125A SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22458	13041-20000-08373	621 S SPRING ST BASEMENT	90014	14	127-5A211  12	5144024***	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.04533	-118.25178	CHANGE OF USE AND TENANT IMPROVEMENT OF 4550 SF BASEMENT FROM GALLERY TO  A FITNESS GYM.  THIS IS A HIGHRISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22459	16041-30000-29135	2029 S CENTURY PARK EAST 29th FL	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Titel 24 only in existing high-rise 29th Floor. Total ligting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22460	19041-10000-24044	2731 W BEVERLY BLVD	90057	13	138A203   455	5156020018	C2-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM			PC Approved	06/21/2019 12:00:00 AM	ADDRESS	34.07044	-118.27861	Energy plan check for a corridor of a 4 story hotel T.I. Sope includes new lighting and equipment with a total lighting area of 3292-SQ FT. Note. permit fee is paid under 19041-70000-13754.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22461	16041-20002-23924	1441 S VETERAN AVE 1-111	90024	5	129B153   139	4324013032	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			10/17/2016 12:00:00 AM			PC Approved	10/17/2016 12:00:00 AM	ADDRESS	34.05268	-118.44373	10/17/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to accomodate a line-side tap for the PV system. *****Previous Work Description*****RSES expedited plan check feePV2.  Install 155 kW DC roof-mounted PV system.  (456) modules with (4) 24kW and (1) 20kW transformerless central inverters	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22462	17041-20001-02165	7820 N VENTURA CANYON AVE	91402	6	189B157   734	2301012087	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.21263	-118.42858	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with a 200A MSP.12.48kW ungrounded system. (52) EnPhase M250 microinverters. (52) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22463	17041-10000-01155	10250 W SANTA MONICA BLVD SUITE 1850	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR RETAIL TI ""ANYTHING BUT WATER"" NEW LIGHTING. PC FOR FIRST TIME TI IN WESTFIELD CENTURY CITY. SUITE 1850"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22464	19041-10000-35076	2723 W 8TH ST	90005	1	132A201    11	5077020026	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.05787	-118.28484	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22465	18041-20002-48286	403 S HIGHLAND AVE	90036	4	135B185   254	5507013001	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2019 12:00:00 AM			PC Approved	03/08/2019 12:00:00 AM	ADDRESS	34.06668	-118.33875	PLAN CHECK ONLY, SUPPLEMENTAL FOR CHANGE TO APPROVED SET, CHANGE OF PV MODULE LAYOUT ON ROOF*ORIGINAL*Plan check for a PV1 roof-mounted PV system. System size is 13.68 kWdc/12.31 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (38) modules.Note: Permit fee due to CA Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22466	18041-10000-20550	642 N SAINT CLOUD ROAD	90077	5	144B153   881	4362017050	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	01/04/2022 12:00:00 AM	ADDRESS	34.0872	-118.44004	PLAN CHECK FOR POWER ONLY.  NEW SINGLE FAMILY DWELLING WITH 1200AMP 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. BUILDING PERMIT # 15010-10000-02171	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22467	11041-20000-08573	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check for new branch circuits to existing subpanel for Kaiser Permanente Ambulatory Care Facilities.  Per applicant request, plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22468	13041-10000-32311	9110 N HADDON AVE	91352	6	195B165    27	2629014117	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.23473	-118.40063	PV1, Install 4.5 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 18 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22469	14041-10000-03661	950 S SANTEE ST #5	90015	14	126A209   194	5145016054	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.039	-118.25456	TI in an existing retail. Replace existing fixture with fluoresent.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22470	16041-20000-22010	11102 W MAGNOLIA BLVD	91601	2	171B173   615	2353005004	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.16478	-118.37263	Plan check for Title 24 only change of use from retail to restaurant in existing space. Total area:2,500 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22471	19041-20001-06372	6410-6512 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM			PC Approved	07/29/2019 12:00:00 AM	ADDRESS	34.1873	-118.64251	7/29/19CHANGES TO AN APPROVED SET OF PLANS.  CHANGES TO REFLECT AIC RATINGS ON EXISTING GEAR (RITE AID).  THIS IS PLANC HECK ONLY.  ((((Plan check for power only. Project site is an existing commercial shopping center. Project scope is changing existing electrical services from overhead to underground.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22472	09041-10002-23630	8569 W BURTON WAY 1-4	90048	5	138B173   858	4334009032	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			09/13/2011 12:00:00 AM			PC Info Complete	09/13/2011 12:00:00 AM	ADDRESS	34.0725	-118.37882	FOR UNITS P401 & P402, PANELBOARD UPGRADED TO 200A AND INSTALLED AN ELECTRIC RANGE,DRYER, STEAM SHOWER,HP UNIT,AH UNIT AND AN ELECTRIC OVEN CALCULATIONS FOR THE LOAD ON THE NEW PANELBOARD AND SERVICE WERE MADE((((((((Renovation of two units, addition of second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22473	12041-20000-07138	800 W WILSHIRE BLVD #1410	90017	9	129A209    32	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.0493	-118.25841	Tenant improvement on 14th floor of high rise commercial. T-24 Plan Check for Energy and Emergency Lighting. 2075sqft indoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22474	11041-10000-15493	708 W FLORENCE AVE	90044	8	102B201   932	6020027004	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM			PC Info Complete	04/19/2012 12:00:00 AM	ADDRESS	33.97448	-118.28642	CHANGE OF USE FROM WAREHOUSE TO RESTAURANT (PIZZA TAKE-OUT).  PLAN CHECK IS FOR ENERGY AND POWER.PERMIT WAS OPTAINED ON 12041-90000-22900	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22475	17041-10000-46297	1601 E OLYMPIC BLVD BLDG. 300	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.02923	-118.24056	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLYVALLEY PRODUCE #305	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22476	17041-30000-19281	1804 S LINCOLN BLVD	90291	11	111B149  1374	4242007012	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	33.99641	-118.4572	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a core and shell. Tenant improvement to be under separate permit. Total lighting area = 2,458 sq. ft.Note: Building permit has been issued under 16016-10000-12440	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22477	17041-10000-36590	2010 W 62ND ST	90047	8	105B189  1017	6001020015	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM			PC Info Complete	04/08/2019 12:00:00 AM	ADDRESS	33.98325	-118.31394	NOTE: FEES ARE $0 DUE TO AB 1414.PV2. PC FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL BUILDING. ***SYSTEM IS A FEED AND TRAIFF***TOTAL SYSTMEN SIZE 65.4KWDC /64KWACINCLUDES 218 MODULES WITH 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22478	18041-10000-45653	11505 W OLYMPIC BLVD	90064	11	123B153   116	4260005900	C2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.03648	-118.44457	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22479	19041-10000-46808	14715 W AETNA ST	91411	6	177A149    67	2241025001	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.18023	-118.4536	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22480	12041-20000-20747	9133 W ORIOLE WAY	90069	4	147B169   785	5560006012	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM			Reviewed by Supervisor	11/08/2012 12:00:00 AM	ADDRESS	34.09669	-118.38927	Plan check for power, single family dwelling. 600A service. New building. 8000sqft house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22481	11041-20000-23172	5654 N ELMER AVE	91601	4	174B173   691	2337034005	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	ADDRESS	34.17376	-118.37619	pv system 7.6 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22482	17041-20000-02757	4419 N FIGUEROA ST	90065	1	147A223   287	5467005027	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1851.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.09571	-118.20777	PLANCHECK FOR POWER AND ENERGY. REMODED AND ADDITION OF EXISTING CARWASH. SERVICE UPGRADE. building p# 15014-10000-03681	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22483	11041-20000-12394	888 S FIGUEROA ST 5th Flr	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	34.0465	-118.26225	Plan check T24 Energy (general/emergency) lighting on the 5th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22484	19041-30000-16358	2029 S CENTURY PARK EAST Ste 1600N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is an existing tenant suite on the 16th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 23,599 sq. ft.Note: Building permit has been issued under 19016-10000-02975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22485	19041-10001-08969	18887 W CARMEL CREST DR	91356	3	162B121   154	2177048006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM			PC Approved	03/27/2019 12:00:00 AM	ADDRESS	34.14129	-118.54607	Expedite per applicant request(((Plan check for a 11.4KW AC / 11.5KW DC rooofmounted system with (2) inverters, (2) batteries, (32) modules and power optimizers feeding a back up panel, load center and the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22486	18041-10000-27134	5343 W IMPERIAL HWY #300	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	33.93128	-118.37337	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22487	19041-10000-15766	1249 W 39TH PL	90037	8	117B197   911	5037007022	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			04/29/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	07/02/2021 12:00:00 AM	ADDRESS	34.01423	-118.29903	FULL PLAN CHECK FOR NEW 1600A, 120/208V, 3PH, 4W SERVICE. SCOPE OF WORK INCLUDES PANELS, EQUIPMENTS AND LIGHTS. B# 18010-20000-03759	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22488	13041-10000-05255	1413 N L. RON HUBBARD WAY ASHO-BLDG	90027	13	147B197   870	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.097	-118.29419	PLAN CHECK POWER AND ENERGY. CHURCH OF SCIENTOLOGY AMERICAN SAINT HILL ORGANIZATION (ASHO) BUILDING TI. MODIFICATION TO SEPARATE FIRE ALARM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22489	10041-20000-15218	21526 W VENTURA BLVD	91364	3	171B105    60	2168001053	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	12/06/2010 12:00:00 AM	ADDRESS	34.16796	-118.59949	BIKE SHOP. EXISTING SERVICE. P/C IS FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22490	12041-20001-09357	7361 N LAUREL CANYON BLVD	91605	6	186B165   260	2307022010	M2-1VL, P-1VL, R1-1, R2-1	South Valley	North Hollywood	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	34.20451	-118.39671	Plan  Check per customer request for a new trailer building.((SUPPLEMENTAL APPLICATION TO ORIGINAL PLAN CHECK. CHANGES FOR REDUCTION OF NUMBER OF PANELS. PLAN CHECK ONLY. PERMIT ALREADY ISSUED. CHANGES CLOUDED))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22491	19041-10002-43252	1804 S COCHRAN AVE	90019	10	126B177   336	5067020003	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Apartment			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Closed	12/06/2019 12:00:00 AM	ADDRESS	34.04403	-118.35378	Permit to include the new 100A subpanel to the scope of work. Panel was shown on the single line but not charged for.  PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3KWac/4.060KWdc. SCOPE OF WORK INCLUDES 14 MODULES (HYUNDAI HIS-S290RG) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE3000H-US).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22492	19041-20000-05148	15416 W MONTE ST	91342	7	228B145   477	2501018016	RS-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.31799	-118.46719	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 27 MODULES (Type : CANADIAN SOLAR CS1K-325MS ) AND 1 CENTRAL INVERTER (Type : SMA SB 7.7 ).  SYSTEM SIZE IS 8.78 KWdc and7.7 KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22493	14041-10000-14945	2466 N HIDALGO AVE	90039	13	148-5A209 199	5440014028	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.10194	-118.25625	PV1, INSTALL 9.18 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22494	14041-20001-16769	23388 W MULHOLLAND DR	91364	3	168B093   135	2068001003	(T)RS-1XL, R3-1, RA-1, RA-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.1563	-118.63495	EXPEDITE PER CUSTOMER REQUEST.PLAN CHECK FOR POWER DISTRIBUTION TO MOBILE MODULES. TEMPORARY POWER TAP FROM EXISTING 3000A SERVICE TO POWER TEN MOBILE MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22495	16041-10000-24186	940 W CHANNEL ST	90731	15	021B197   342	7445013026	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	33.75392	-118.2977	PV1 ROOFTOP SOLAR ON A SFD TOTAL SYSTEM SIZE 5.8KW AC USING AC MODULES TOTAL OF 18.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22496	17041-10000-38173	22016 W NAPA ST	91304	12	192B101   105	2010013010	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.22564	-118.60682	PC for new roofmounted 6.21kW PV system. Installing 20 AC modules and one new combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22497	13041-10002-05333	2391 N ROSCOMARE ROAD	90077	5	153B145    35	4378018002	RD2-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Apartment			10/17/2016 12:00:00 AM			PC Info Complete	10/25/2016 12:00:00 AM	ADDRESS	34.1187	-118.46392	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGES TO GARAGE EXHAUST FAN - INCREASE IN SIZE. CHANGES TO HOUSE PANEL LOAD LAYOUT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22498	11041-20000-15124	11852 N BALBOA BLVD	91344	12	216B133   474	2610002048	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	ADDRESS	34.28546	-118.50127	PLAN CHECK T24 ENERGY IN EXISTING TENANT SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22499	17041-20000-31997	11961 N STEWARTON DR	91326	12	216B121   203	2820016013	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.29056	-118.54223	Plan check for a PV1 roof-mounted PV system. System size is 6.4 kWac and consists of (28) micro-inverters, (28) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22500	18041-20000-40094	10920 N GOTHIC AVE	91344	12	210B137   813	2680019022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	PIN	34.26895864	-118.48887673	Plan check for PV roof mounted system, system size: 9.21KW AC CEC with 33 PV modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22501	19041-20001-11122	23150 W AVENUE SAN LUIS	91364	3	171B093   784	2074021035	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.16135	-118.63106	Expedite per appliant request Plan check for PV roof mounted system, system size: 83kW with 228 PV Modules and 2 inverters(33KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22502	11041-10000-21499	1701 E CESAR E CHAVEZ AVE ste 306	90033	14	130-5A221 204	5174007047	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	01/12/2012 12:00:00 AM	ADDRESS	34.05126	-118.2173	Health care T.I., new receptacles and switches and relocate 45kva transformer.  No change to lighting, per applicant.  Plan check for POWER.  Suite 306	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22503	17041-20002-40715	12293 N WOODLEY AVE	91344	12	219B137   160	2609014036	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	34.29331	-118.49138	EXPEDITED PER APPLICANTS REQUEST.PV1. CONNECTED TO EXISTING SOLAR SYSTEM.  ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.8 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22504	13041-10002-29369	5200 W CENTURY BLVD	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	33.94516	-118.37049	VFD part of chillers CH1 and 2. Disconnect added to CAC-1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22505	14041-10000-33003	2525 W WILSHIRE BLVD	90057	1	133-5A201  95	5141006017	C4-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/09/2021 12:00:00 AM	ADDRESS	34.06059	-118.28114	New 7-story  construction  for mixed-use development including 2 levels of subterrean parking garage , total 153 units and retails.  (2) new 3000A 120/208V services, power and lighting to residential and commercial areas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22506	18041-10000-10398	443 S SOTO ST	90033	14	126A223   132	5183014033	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM			PC Info Complete	07/27/2018 12:00:00 AM	ADDRESS	34.03963	-118.21264	FULL PLAN CHECK FOR A NEW 3 STORY CHARTER SCHOOL. NEW 480/277V, 1600AMP, 3PH SERVICE.T-24 FORMS ARE UNDER PERFORMANCE METHOD. TOTAL SQ.  41719Fire alarm variance has been submitted. variance for (2) services has been submitted prior to letter from LADWP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22507	10041-10000-23452	6161 W CENTURY BLVD	90045	11	090B165     6	4124030034	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	07/25/2011 12:00:00 AM	ADDRESS	33.94571	-118.39319	T-24 lighting plan check for  INTERIOR TI UPGRADES TO EXISTING GUESTROOMS OF HOTEL (185 GUESTROOMS TOTAL)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22508	19041-20000-47497	550 N GOWER ST	90004	4	141B189   888	5523027010	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	05/21/2020 12:00:00 AM	ADDRESS	34.0804	-118.32256	PV1.  Install 5.6 kW roof mounted grid tied PV system.  (14) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22509	15041-10000-09122	12126 W WATERFRONT DR Parcel-2	90094	11	105B161  1203	4211010051	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Closed	12/13/2016 12:00:00 AM	ADDRESS	33.98076	-118.40716	temp POWER FOR CONSTRUCTION SITE, PLAYA VISTA 600 A. PC FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22510	14041-20000-14429	16310 W RAYEN ST	91343	12	195B137   424	2688018036	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.23192	-118.48793	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.61KW INTERCONNECTED WITH MAIN PANEL.(22) TRINA SOLAR MODULES(1) SOLAREDGE SE5000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22511	17041-10001-09006	10250 W SANTA MONICA BLVD #1585	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1st revision to approved set for ""LIFEHOUSE""  IN WESTFIELD CENTURY CITY. SUITE 1585. This scope is to revise single line diagram to correct tenant's service source as 208/120V from 480/277V as previously stated. This is plan check only, no supplemental permit is needed."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22512	12041-10000-16389	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TI- OFFICE EXPANSION ON 15TH FLOOR OF OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22513	16041-10000-18531	10889 W WELLWORTH AVE	90024	5	132B153   596	4325005026	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.0572	-118.4423	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (CVS PHARMACY). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 946 SQ. FT.Permit fee is paid on 09/06/16 under 16041-10000-31492.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22514	15041-10000-04953	738 S OGDEN DR 1-12	90036	4	132B177   106	5086021015	R3-1	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Public Safety Only			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.0615	-118.35982	NEW FIRE WARNINGSYSTEM FOR 3-STORIES, 12 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22515	13041-10000-21190	14826 W VANOWEN ST 1-8	91405	6	180B149    18	2236001018	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.19366	-118.45619	"pc for energy only with emergency lighting in the indoor corridor. STORY, 62'6""X57'1"", TYPE V-B, R2 OCC, 8-UNIT APARTMENT BUILDING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22516	14041-10000-34785	10900 W MAGNOLIA BLVD	91601	2	171B173  1381	2419001041	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.16471	-118.3681	TI existing ralphs market. T24. Total area = 32,413 sq. ft. Decor lighting	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22517	13041-10000-32386	9709 N GLADBECK AVE	91324	12	201B121   455	2763033028	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Expired	02/11/2016 12:00:00 AM	ADDRESS	34.24674	-118.53983	Roof mounted PV system with 6KW for single family dwelling.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22518	17041-10000-13047	19481 S HARBORGATE WAY	90501	15	057B193    21	7351021016	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.85326	-118.30372	PC for energy only, Outdoor and Indoor Title-24.  Removing HID fixtures and replacing with New LED. area: 145,100.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22519	11041-10000-25140	18926 W CELTIC ST	91326	12	210B121   705	2718012020	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2011 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.26875	-118.5459	PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22520	19041-20000-05454	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.0484	-118.26248	TI to (E) commercial office space.  Plan check for energy - 583 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22521	15041-10000-33428	601 W 5TH ST 10TH FLR	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Expired	11/03/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	PC FOR PENERGY. REMODELING OFFICES FOR OFFICE T.I LOCATED IN THE 10TH  FLOOR OF A HIGH RISE BUILDING. TOTAL AREA 2430 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22522	14041-10001-12798	507 N BEACHWOOD DR	90004	4	141B189  1108	5523027037	R1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.0792	-118.32182	((Expedite fees))PV electrical generating system for existing residential buildingsystem size = 5.1 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22523	16041-10001-16332	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	33.76597	-118.28407	void... for fee calculation onlyPV2 5.1 Mega watts roof-mounted system with 23,184 modules, and 64 inverters interconnecting through utility transformers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22524	13041-20000-22118	16832 W MARILLA ST PV-1	91343	12	201B133   356	2686016024	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.24776	-118.49924	PV-1. Rooftop AC. 7.2kW AC, one 3kW and one 4.2kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22525	19041-10000-25022	5880 W VENICE BLVD	90019	10	126B173   696	5064029908	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.04068	-118.36772	INSTALLING NEW DISTRIBUTION BOARD TO POWER (2) SEWER GAS SCRUBBERS.  FULL PLAN CHECK FOR HAZARDOUS LOCATION CLASS 1 DIV 2.INSPECTION TO VERIFY FIELD EVALUATION FOR CONTROL PANEL(LISTING AND 17.8KA EQUIPMENT RATING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22526	10041-10000-07501	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.02224	-118.28008	First tenant in commercial space-RETAIL/PHARMACY-CVS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22527	11041-10000-13499	15800 W VENTURA BLVD	91436	5	168B141   643	2283009014	C4-1L, R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.15528	-118.47771	RELOCATING A VEHICLE FUEL TANK AND PUMP ON A CAR LOT.  PLAN CHECK IS FOR POWER.   COMPLY WITH DEPARTMENT ORDER effective date 12/17/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.  CEIS CASE NUMBER IS 79615	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22528	11041-20000-11667	8405 N LAUREL CANYON BLVD	91352	6	192B165   892	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	06/08/2011 12:00:00 AM		Permit Finaled	08/05/2011 12:00:00 AM	PIN	34.22353337	-118.39700659	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO (E) RETAIL STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22529	17041-30000-08153	24050 S FRAMPTON AVE	90710	15	039B197    13	7439010018	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Issued	03/14/2017 12:00:00 AM	ADDRESS	33.8059	-118.29973	Plan check for power only. Project site is an existing commercial building. Project scope is the replacement of a damaged 600-amp distribution section and main meter section.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22530	10041-10000-03326	10704-10718 S WILMINGTON AVE	90002	15	090A215   668	6068001001	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00, 2430.00	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	05/03/2010 12:00:00 AM		Permit Finaled	10/06/2010 12:00:00 AM	ADDRESS	33.93873	-118.23889	PLAN CHECK POWER AND ENERGY FOR NEW 3 STORY CHARTER SCHOOL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22531	14041-10000-11171	17720 W MAGNOLIA BLVD	91316	5	171B129   198	2162013005	(T)(Q)R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Apartment			04/28/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.16526	-118.51937	NEW FIRE ALARM SYSTEM FOR 4 STORY APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22532	17041-20000-30476	9340 N PENFIELD AVE	91311	12	198B113    95	2761040017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.24067	-118.56948	Plan check for a PV2 roof-mounted feed-in tariff PV project. System size is 400 kWac and consists of (5) inverters, (1,220) modules, and (2) load center.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22533	19041-20000-52649	4969 W SANTA MONICA BLVD	90029	13	144B197   730	5540009007	C2-1D	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Info Complete	12/19/2019 12:00:00 AM	ADDRESS	34.09098	-118.29791	Plan check for Title 24 Energy only for outdoor lighting. Total area: 18,432 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22534	14041-10000-29559	7920 W SUNSET BLVD	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	34.09787	-118.36238	Plan check for Title 24 only for an existing high-rise building. Work being done on the 5th floor only.Area = 6890 sq. ft. Installating of 77 new light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22535	19041-10000-42838	1638 E 27TH ST	90011	9	115-5A213  37	5117004018	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	03/05/2021 12:00:00 AM	ADDRESS	34.01231	-118.24431	NEW PV1 ROOF-TOP INSTALLION WITH 8 MODULES (CANADIAN SOLAR), 1  INVERTER (SE3000H), 8 OPTIMIZERS (P320), AND 1 SUB-PANEL (125 AMPS) CONNECTED TO AN EXISTING SERVICE OF 200 SYSTEM SIZE: 2.4 KW DC;3.0 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22536	19041-10000-09166	9440 N CHIVERS AVE	91352	6	198B173    24	2408040031	RA-1-K-CUGU, [Q]MR1-1-CUGU, [T][Q]MR1-1-K-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1211.02	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.2405	-118.36934	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR)- T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22537	17041-20000-41697	675 N PERUGIA WAY	90077	5	141B149   190	4362003034	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.08155	-118.45037	Plan check for power only. Project site is a new 2-story single-family dwelling with basement and attached garage. Work includes a new 1,200-amp service.Note: Building permit has been issued under 13010-10000-04430. Electrical permit fees have been paid under the issued building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22538	16041-10001-28553	8930 N LEMONA AVE	91343	6	195B145   175	2651020040	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.23282	-118.45939	EXPEDITE PER APPLICANT REQUEST. ((((PV1. ADDING A NEW SOLAR SYSTEM TO AN EXISTING PV SYSTEM. ADDING A NEW 2.580KWac to an existing 3.0kWac system. Total system size with new and existing is 5.583KWac.(12)MODULES-HYUNDAI His-S260RG(12)MICROINVERTERS-ENPHASE M215-602LL-S22(240)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22539	19041-10000-21588	12520 W SHERMAN WAY	91605	2	183B161    65	2324034019	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.20097	-118.40599	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22540	19041-20000-29380	13232 N WHEELER AVE pv1	91342	7	225B157   987	2512011021	(Q)R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM			Not Ready to Issue	07/30/2019 12:00:00 AM	ADDRESS	34.31112	-118.42477	pv1install roof mounted pv system sized 6KW AC to an existing pv system interconnected with msp.permit fees paid under application number 19041-90000-25562this is plan check only.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22541	15041-20000-08141	7200 W FOOTHILL BLVD #102	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.24842	-118.28878	Plan check for T-24 only for yogurt shop. Total area: 963 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22542	19041-20000-30077	17010 W CHATSWORTH ST	91344	12	207B133   521	2695001013	(Q)C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.26455	-118.50276	TI to (E) commercial space.  (1) medical patient care room.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22543	15041-20001-38574	8857 N LARAMIE AVE	91306	3	195B113    94	2781032031	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.23153	-118.57343	EXPEDITE PER APPLICANT REQUEST((((((Plan check for PV roof mounted system addtion to existing system. System size: 3.0kW. with 9 modules and 1 inverter(3.0kW). Existing system: 10kW System with 2 inverters(5.0kw ) connected to load center)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22544	13041-10001-21459	1825 N BRONSON AVE 1-33	90028	13	150A191   280	5586027006	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			08/19/2014 12:00:00 AM			PC Info Complete	09/30/2014 12:00:00 AM	ADDRESS	34.10425	-118.31823	power and energy. APARTMENT BUILDING. REPLACING 40 PANELS, 33 of 40 ARE UNIT PANELS.  EXISTING BRANCH CIRCUITS TO REMAIN, RECEPTACLES TO BE REPLACED IN THE SAME LOCATION. Changes on plans include AFCI breakers, fully rated for 32kaic, and delta load calcs((((   changes made to previously approved set.)))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22545	16041-10001-45790	380-384 WORLD WAY MSC   Temp-Power	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan Check for Temporary power changes, MSC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22546	10041-10000-19739	15015 W CORONA DEL MAR	90272	11	123B129   637	4411024007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.03183	-118.52283	INSTALLATION OF 19KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22547	13041-20001-03925	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.0344	-118.45642	Modifications to approved set.  Inverter load schedule added, other minor equipment location changes stemming from architectural revisions.  (((PC FOR ENERGY ONLY. TI TO EXISTING BLDG (RESTROOMS AND OUTDOOR LIGHTING). LESS THAN 400A)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22548	19041-10000-51985	771 S TOWNE AVE	90021	14	126A213   584	5146027029	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	03/23/2022 12:00:00 AM	ADDRESS	34.0381	-118.247	Replacing Existing HID Fixtures with new indoor & outdoor LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22549	19041-10001-24701	1411 W 190TH ST SUITE 350	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM			PC Approved	09/27/2019 12:00:00 AM	ADDRESS	33.85852	-118.30317	PLAN CHECK FOR ENERGY ONLY, Interior, non-structural tenant improvement to (E) office space.  Scope of work to includes new lighting and receptacles to existing circuits. Total sq. ft. 2182. permit fees under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22550	15041-20000-03857	4823 N ATOLL AVE	91423	4	168B157   287	2358015015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2015 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	34.15841	-118.42052	PC FOR PV1 SFD. TOTAL SYSTEM SIZE 3KW AC. THIS IS AN ADDITION TO AN EXISTING SYSTEM. PC FOR THIS ADDITION AND TOTAL SYSTEM INTERCONNECTION. THIS SYSTEM CONTAINS 3KW INVERTER WITH POWER OPTIMIZERS. 9 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22551	18041-20000-34814	11601 W WILSHIRE BLVD STE 2150	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing high-rise building Office T.I. Total area: 5828 sq ft. B#18016-10000-26297	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22552	15041-20000-15146	11447 N GOTHIC AVE	91344	12	213B137   669	2681003003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2015 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.27865	-118.48924	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING STANDARD PLAN. TOTAL OF 28 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22553	17041-30000-14536	953 N NORMANDIE AVE	90029	13	144B193  1201	5537025005	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Apartment			05/02/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.08777	-118.30076	Plan check for new appartment power and energy 10 units appartment 1000A Service. Total area: 11,867 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22554	17041-10000-11762	120 N ROBERTSON BLVD Suite G	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.07585	-118.38356	FULL PLAN CHECK FOR A TI ON EXISITNG RESTAURANT. NEW LIGHTING AND POWER. NEW ADDED LOAD IS GREATER THAN 400 AMPS. TOTAL AREA 11,578 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22555	19041-10002-40996	737 S LAMAR ST	90031	14	135A219   168	5410013011	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.06375	-118.22383	This application is a plan check only for the second pv system, all permit fees for both the first and second system are under  19041-10000-40996Orginal scope:(plan check for PV-2 system system has two components:1-system (1):(602)Hyundai HIA-S375HI modules, 225.8KW DC(2)SMA PV1 62-US-41 62KW inverters(1)SMA PV1 50-US-41 50KW inverters174KW AC total2-system (2):(238)Hyundai HIA-S375HI modules, 65.8KW DC(2)SMA PV1 33-US-41 62KW inverters66KW AC total(1)75KW AC )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22556	19041-10000-03675	10937 S CENTRAL AVE	90059	15	088-5A209 232	6071020015	MR1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Issued	01/31/2019 12:00:00 AM	ADDRESS	33.93613	-118.25439	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22557	15041-10000-01847	11645 W WILSHIRE BLVD	90049	11	129B145   489	4265001036	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Public Safety Only			01/21/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	PIN	34.0501741	-118.46033667	Fire alarm system upgrade- new FP and some devices and power extenders.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22558	18041-10000-20364	2100 W 54TH ST	90062	8	108B189   645	5005010019	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Info Complete	10/03/2018 12:00:00 AM	ADDRESS	33.99307	-118.31622	PC FOR POWER AND ENERGY FOR TI IN A CHURCH. SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS. TOTAL CONNECTED  LOAD <400AOCCUPANT LOAD >100 PER APPLICANT.TOTAL AFFECTED AREA 5745 SQ.FT.B#18014-30000-01994	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22559	16041-10000-30756	2008 S SAWTELLE BLVD	90025	11	126B153   676	4261032054	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Closed	08/16/2022 12:00:00 AM	ADDRESS	34.04081	-118.44331	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM (E) RETAIL TO (N) TAKE OUT RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 945 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22560	17041-10000-43650	2847 W LEEWARD AVE	90005	1	133-5A201 214	5077015011	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/14/2023 12:00:00 AM	ADDRESS	34.05886	-118.28554	PC for methane detection system on building with six stories above grade and two stories below grade. Installing 17 new devices, methane detection panel and fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22561	15041-10000-12131	6700 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.19196	-118.6056	NEW FIRE ALARM SYSTEM 200 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22562	13041-10000-16944	900 N ALAMEDA ST 3rd floor	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.05855	-118.23671	pc for poweronly.  existing data center. ADDITION OF UNDER THE FLOOR POWER WHIPS FOR DATA CENTER CAGE BUILD. >400A. raised floor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22563	18041-10000-48987	23279 W VENTURA BLVD	91367	3	171B093   768	2044026***	CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.16167	-118.63343	TITLE 24 PLAN CHECK FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22564	19041-10000-52770	953 N SYCAMORE AVE # 701	90038	4	144B181   641	5531015014	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.08865	-118.34299	Full plan check for a first time T.I located d on the 7th floor in Suite#701. Installing Panels, Lights, Circuits, with a total lighting area of 2,680-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22565	18041-20000-43620	16854 W MOONCREST DR	91436	5	165B133   400	2291010023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.14723	-118.50085	PV1.  Install 8.64 kW roof mounted grid tied PV system alongside an (E) 11.25 kW PV system.  (24) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22566	14041-10004-17723	730-736 S LOS ANGELES ST	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			05/16/2017 12:00:00 AM			PC Info Complete	06/14/2017 12:00:00 AM	ADDRESS	34.04254	-118.25109	CHANGES TO AN APPROVED SET OF PLANS UNDER CLOUDED PORTIONS - CHANGES INCLUDE (3 NEW PANELS, CHANGE OF FEEDER SIZES FOR EXISTING PANELS,  ADDITION OF ELECTRIC DRYERS (FOR 25 UNITS, REMAINING UNITS STILL USING GAS DRYER), SERVICE LOAD CALCULATIONS CHANGES, AND RELOCATION AND ADDITION OF NEW LIGHTING).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22567	11041-10000-25886	4503 S GLENCOE AVE	90292	11	105B153   102	4212007009	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	33.98462	-118.43524	Plan check power and energy for officeTI  with existing services. New panel, branch circuits, equipment, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22568	18041-20000-41888	5623 N FAIRHAVEN AVE	91367	3	174B085    93	2046009016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.17276	-118.6582	Plan check for PV roof mounted system, system size: 14.52KW DC, 12.342KW AC with 44 PV modules and 44 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22569	13041-20000-11870	601 S FIGUEROA ST 39TH FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON 39TH FLOOR. 1250 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22570	18041-10000-24044	1780 N GRIFFITH PARK BLVD	90026	13	147A203   494	5429016023	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.09537	-118.27611	PC FOR SERVICE UPGRADE FOR EXISTING APT BUILDING. SCOPE INCLUDES  NEW 600A SERVICE 1P 120/240V, NEW MSP AND HOUSEPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22571	17041-20000-18082	21310-21314 W LASSEN ST	91311	12	201B105    82	2746004007	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.24975	-118.59537	PLANCHECK FOR NEW SECOND SERVICE TO EXISTING BUILDING. 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22572	11041-20000-08515	15200 W SUNSET BLVD Ste 111	90272	11	129B125   727	4412002023	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.02	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	07/20/2011 12:00:00 AM	ADDRESS	34.04624	-118.52472	T.1.  EXISTING OFFICE SPACE.  REPLACING LIGHTING FIXTURES TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22573	15041-20000-26526	16133 W VENTURA BLVD Suite 1000	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.15675	-118.4847	Title-24 plan check only  Total area = 2,732 sq. ft.  T.I. to existing commercial highrise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22574	19041-10000-40737	10200 S SUCCESS AVE	90002	15	090B209   381	6048012029	C4-2D-CPIO	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	04/10/2020 12:00:00 AM		Permit Finaled	10/19/2021 12:00:00 AM	ADDRESS	33.94404	-118.24898	FULL PLAN CHECK FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW BUILDING. SCOPE OF WORK INCLUDES A NEW 1200A SERVICE (120/208 3P, 4W) THAT FEEDS A 1200A MDP., SUBFEEDING VARIOUS MOTORS, AN ELEVATOR, AND THREE SUBPANELS. TOTAL AFFECTED AREA IS 54,613 SQFT. B#: 19010-10K-03683	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22575	15041-10002-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	01/13/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR REVISED SET OF PLANS. CHANGES TO LIGHT, PANEL SCHEDULES AND SINGLE LINE. ALL CHANGES NOTED DELTA 3,4,5 AND 6 ON PLANS. PROVIDED UPDATED FLOOR PLANS FOR NEW HOME RUN DESIGNATIONS AND UPDATED T24 DOCUMENTS. PLAN CHECK ONLY - MOST CIRCUITS ALREADY PERMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22576	18041-10000-11522	21441 W OSBORNE ST SUITE A	91304	3	195B105    38	2779018039	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Issued	03/30/2018 12:00:00 AM	ADDRESS	34.23378	-118.599	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22577	18041-10000-06222	603 E 4TH ST	90013	14	127-5A215 118	5147002012	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.04443	-118.2404	Plan check for T24 only, Change of use of a portion of Auto Shop to Restaurant/Cafe with outdoor eating area and Art Gallery. Reuse (1) panel and install (1) new panel with new connected load < 200A. Total area 1,675 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22578	15041-20001-30219	13714 1/2 SHERMAN WAY	91405	2	183B157   987	2216027023	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	PIN	34.20070651	-118.43211614	04/05/2016 Plan check for power only, per applicant request. *****Previous Work Description*****Title 24 plan check only.  Total area = 948 sq. ft.   T.I. to existing commercial space.  New lighting, recepticles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22579	10041-20000-14510	111 N UNION AVE 2nd Fl	90026	13	135A207   116	5159008800	RD1.5-1	Central	Westlake	Greater Echo Park Elysian	YES	2083.00, 2084.00	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.06525	-118.26562	Plan check T-24 Energy on 2nd floor mechanical room TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22580	13041-10000-05748	380 WORLD WAY Space T45	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	12/21/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 709 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Petrossian).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22581	16041-10000-43632	6457 N SEPULVEDA BLVD	91411	6	180B145   620	2234016004	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.18827	-118.46644	PC FOR ENERGGY. REMOVE HID FIXTURES AND RPLACE WITH NEW LED FIXTURES. TOTAL (OUTDOOR) AREA 23084 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22582	14041-20001-25030	11516 N BALBOA BLVD	91344	12	213B133   620	2610004007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	09/26/2014 12:00:00 AM	ADDRESS	34.27988	-118.50191	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(20) SUN POWER SPR-327 MODULES(1) AURORA PVI-6000 TRANSFORMERLESS INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22583	19041-20001-23267	10642 N BALBOA BLVD B	91344	12	207B133   597	2684001024	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM			PC Approved	07/19/2019 12:00:00 AM	ADDRESS	34.26355	-118.50206	07/19/2019 Change to an approved set of plans. Electrical equipment has been relocated onto the roof and the existing AC unit has been included on the panel schedule.*****Previous Work Description*****TI to (E) commercial retail space.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22584	18041-10000-28602	5901 W CENTURY BLVD Ground Flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Issued	07/30/2018 12:00:00 AM	ADDRESS	33.94572	-118.38685	Energy plan check for a restroom T.I located on the ground floor of a high rise building. Scope includes new lighting and equipment with a total area of 140 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22585	13041-20000-29855	7851 N VENTURA CANYON AVE 1-50	91402	6	189B157   638	2214026008	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.21344	-118.42899	PC FOR FIRE ALARM SYSTEM. 50 UNIT APARTMENT. TOTAL OF 172 DEVICES. 2 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22586	14041-10000-19230	353 S BROADWAY	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.04991	-118.24934	Installation of new fire alarm device in commercial building. Not high rise. Plan check at counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22587	16041-20001-45606	1020 N VERMONT AVE	90029	13	144B197   761	5539003024	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	08/16/2021 12:00:00 AM	ADDRESS	34.09057	-118.2915	SUPPLEMENTAL CHANGES TO APPROVED SET. SCOPE OF WORK INCLUDES CHANGE TO MAIN CIRCUIT BREAKER SIZE, CONDUCTOR SIZE CHANGES, LIGHT FIXTURE MODEL CHANGES/ADDITION, ADDITION OF (3) SUBPANELS, AND ADDING (8) ROOFTOP AC EQUIPMENTS. ALSO INCLUDES CHANGES TO T24 CALCS, VOLTAGE DROP CALCS, LOAD CALCS, AND THE LIGHTING FIXTURE SCHEDULE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22588	19041-20000-27473	7338 N CANBY AVE	91335	3	186B125   759	2119021035	[Q]C2-1VL-CDO, [T]R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.2041	-118.53463	ti to an existing commercial building (non-medical).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22589	11041-10000-20653	1016-1026 E ELKGROVE AVE BLDG 7	90291	11	111B145   666	4243002069	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.00059	-118.45915	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22590	12041-20000-21719	1334 S CENTRAL AVE	90021	14	121-5A213   5	5130008042	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.02855	-118.24651	Plan check for energy and emergency lighting. Cold storage. Coca Cola. 926sqft.Express permit for one 100A panel, two units 5.1-20kVA, and five branch circuits.TENANT IMPROVEMENT: CONSTRUCTION OF A NEW PRE FAB COLD STORAGE ROOM (34FT X30FT X14.67FT HT) WITHIN EXISTING COCA-COLA WAREHOUSE AND NEW WALL OPENING AT EXTERIOR WALL. SEE COMMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22591	10041-30000-07406	10915 W WEYBURN AVE	90024	5	135B149   587	4363018030	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/26/2010 12:00:00 AM		Permit Finaled	05/19/2010 12:00:00 AM	ADDRESS	34.06274	-118.44609	T. I FOR RETAIL STORE. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22592	18041-10000-24707	3600 S CRENSHAW BLVD	90016	10	120B185  1220	5044003017	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.02357	-118.33488	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22593	18041-10002-47200	1186 E MONTECITO DR	90031	1	144A227   482	5304010018	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.08765	-118.19961	DELTA 1 CHANGES TO AN APPROVED SET. CHANGES INCLUDES THE ADDITION OF 4 MODULES TO THE PERMITTED 23 MODULES (TOTAL 27) AND UPGRADE ONE OF THE INVERTERS FROM 3KW TO 3.8KW.SYSTEM UPDATED WORK DISCRIPTION: PV1, INSTALLING 9.585 KWdc , 11.4KWac SYSTEM WITH (27) MODULES , (2) AC INVERTER WITH 7.6 KW AND 3.8 KW,  (17) POWER OPTIMIZER P400 & (10) POWER OPTIMIZER P505	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22594	17041-20001-38931	12406 N RALEIGH CT	91326	12	216B113   214	2701048013	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.29139	-118.57307	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.72 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22595	15041-10005-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	Supplemental PC for changes to approved set. Changes are in lighting, receptacles and equipment. All changes clouded under delta 13,14,15 and 16. Master under 15041-10000-43822.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22596	19041-20000-33581	22940 W HATTERAS ST	91367	3	174B097   266	2041015062	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.17455	-118.627	Plan check for PV roof mounted system, PV system size: 16.64KW with 52 PV Modules and 2 inverters(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22597	16041-20001-41772	13631 N ELDRIDGE AVE	91342	7	228B157   789	2510007001	R1-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.3193	-118.42669	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on a SFD. Interconnect with 200A MSP. Derating the main breaker to 175A. (N) 4.2kW ungrounded system, which is being added to an (E) 7.6kW ungrounded system. (N)(16) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22598	11041-10000-21665	4910 E HUNTINGTON DR SOUTH	90032	14	142-5A233  11	5218008029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.08668	-118.17628	New site lighting for existing bldg. (New service and remodel of exist. bldg. under a separate application,  E11LA01818)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22599	13041-10000-18358	2136 W WASHINGTON BLVD	90018	10	126B193   944	5074033042	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Closed	04/30/2018 12:00:00 AM	ADDRESS	34.03974	-118.30707	PLAN CHECK FOR A NEW 800 AMP SWITCHBOARD. 400A EXISTING SERVICE UPGRADE TO 800A. 10 TENANT SPACES ARE NOT IN SCOPE OF WORK, SHELL ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22600	18041-10000-12406	7548 N WOODLEY AVE	91406	6	186B141   108	2206019020	C1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.20802	-118.48347	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURE AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22601	17041-10001-34870	17134 W OTSEGO ST	91316	5	171B133   494	2258011011	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.16356	-118.50692	expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22602	17041-20001-11996	1031 S WOOSTER ST	90035										Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	07/31/2017 12:00:00 AM	ADDRESS	34.05827	-118.3827	expeditepv2install roof mounted pv system sized 38kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22603	15041-20000-38305	1340 E 6TH ST 3rd Floor	90021	14	126A217   152	5164011001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	06/07/2017 12:00:00 AM		Issued	06/07/2017 12:00:00 AM	ADDRESS	34.03813	-118.23423	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from warehouse to manufacturing/tenant improvement to the 3rd floor. Total lighting area = 40,400 sq. ft.Note: Building application has been filed under 15016-20000-10675	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22604	16041-20000-39273	5764 N CHICOPEE AVE	91316	5	174B129   227	2254020020	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.17592	-118.51212	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22605	13041-20000-28701	16501 W VENTURA BLVD #101	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Issued	10/15/2013 12:00:00 AM	ADDRESS	34.1578	-118.49275	ENERGY PLAN CHECK # 101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22606	15041-10000-07106	7125 N SOPHIA AVE	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.2002	-118.48712	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 30832 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22607	18041-30000-10068	2804 S ELLENDALE PL	90007	9	123B197  1550	5055012021	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.02944	-118.28859	Fire alarm system for an apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (34) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22608	17041-10002-02219	8323 N BALBOA BLVD	91325	12	192B133   235	2690023190	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.22177	-118.50286	RE PLAN CHECK FOR LOST SET OF PLANS. T24 ENERGY ONLY. RESTAMP AS NEW UP TO DATE SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22609	19041-10000-25630	16633 W VENTURA BLVD 6TH FL COR-#601	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.15823	-118.49571	Energy plan check for an office T.I located on the 6th floor of a high rise building. Scope inlcude new lighting and equipment with a total lighting area of 6,867-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22610	18041-10000-47902	8939 N CANBY AVE	91325	12	195B125   265	2769002016	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM			Reviewed by Supervisor	01/17/2019 12:00:00 AM	ADDRESS	34.23302	-118.53504	NEW 13.42 KW ROOF MOUNTED PV SYSTEM FOR A SINGLE FAMILY HOME.PERMIT ISSUED UNDER 19041-10000-25257.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22611	11041-20001-11570	13520 W PAXTON ST A-1	91331	7	210B157  1074	2535002015	M3-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM			PC Approved	06/30/2011 12:00:00 AM	ADDRESS	34.27356	-118.42606	Plan check only. Revision to approved plans, indicated as Delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22612	19041-10000-34167	650 S CROCKER ST	90021	14	126A213   181	5147027039	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			Reviewed by Supervisor	09/13/2019 12:00:00 AM	ADDRESS	34.04044	-118.2453	Second story addition within (E) 1-story warehouse building envelope, tenant improvement and change of use from warehouse to manufacturing, indoor nursurey and warehouse. First time occupancy on the second floor. Total added load is 399Amp on an existing 400Amp Service. Total Area:7327 Sqr Ft.Bulding Permit: 19014-10000-03434 (Pending)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22613	11041-10000-24507	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Wiring and equipment installation for end-use equipment to serve:(1) Passenger Boarding Bridge(s) (PBB) for TBIT North Concourse, Gate Nos. 130, 132, and 134 and  (2) Passenger Boarding Bridge(s)  TBIT South Concourse, Gate Nos. 150, 152, 154, and 156. Submittal 2 is for collection of additional P/check fees only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22614	14041-10000-03123	3575 E WHITTIER BLVD	90023	14	121-5A227 227	5188005015	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	34.02583	-118.1962	pc for power and energy. Medical - OSHPD 3.  not methane. 1 story.14016-10000-02112 description: T.I. FOR 24 STATION DIALYSIS CLINIC. CONVERT EXISTING BLDG TO TYPE V-A, W/ STRUCTURAL UPGRADES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22615	15041-10001-39388	20916 S DALTON AVE	90501	15	051B193    29	7349006022	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.83932	-118.30266	{Dept. error] Revised qty. of modules. Under Permit 15041-10000-39388, the fee item information its (24) modules while it should be (42) total modules. No PC needed. Zero dollar fee under the California Senate Bill 1222.**PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(42) SILEV MODULES(2) ABB INVERTERS 6/4.2 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22616	19041-20000-03854	6333 W 3RD ST #E-10	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	Plan check for Title 24 only in existing space Tenant Improvement, total area: 222 sq ft B#19016-20000-03025	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22617	16041-10000-39048	143 E 93RD ST	90003	8	093A205   457	6052002025	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM			Corrections Issued	11/03/2016 12:00:00 AM	ADDRESS	33.95203	-118.27234	Installation of new roof-mounted solar PV system. Total system size = 3.0KVAInverter (SUNNYBOY 3000TL), WITH (8)PV MODULES (SOLAR WORLD SW 285), and new subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22618	15041-20000-07458	6720 S CENTINELA AVE	90230	11	105B165   463	4220006911	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	33.98393	-118.40409	Plan check for power and energy.  Total area = 4,612 sq. ft.Construction of new vector control operations center.  New 600 A service.  Project is located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22619	17041-10001-41365	15121 W MONTE ST	91342	7	228B145   158	2502026050	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM			PC Approved	01/05/2018 12:00:00 AM	ADDRESS	34.32177	-118.46341	expedite fees per applicant request..NEW ROOF MOUNTED PV SYSTEM. CONSISTS OF 55 MODULES (HYUNDAI 300W HiS-S300RG) AND 2 INVERTERS(SOLAREDGE SE6000A-US and SE7600A-US)SYSTEM SIZE IS 16.5KWdc/13.6KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22620	10041-20000-03278	16461 W SHERMAN WAY	91406	6	186B137   239	2205010905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Issued	11/18/2010 12:00:00 AM	ADDRESS	34.20137	-118.49193	Plan check power for taxiway lighting at Van Nuys Airport.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22621	17041-10000-01695	9620 W VENICE BLVD	90232	5	120B165   941	4207001039	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.02448	-118.39627	PC for T24 energy only for retail area with 3030 sqft.  PC for new lights and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22622	10041-10000-08345	6920 W SUNSET BLVD	90028	4	147B181   691	5548016043	C4-2D-SN, RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Closed	03/22/2012 12:00:00 AM	ADDRESS	34.0978	-118.3411	REPLACING LUMINAIRES IN A RETAIL STORE; ALL EMERGENCY LUMINAIRES  AND EXIT SINS ARE EXISTINGPLAN CHK IS FOR TITLE 24 AND EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22623	19041-10000-33831	17614 W LUDLOW ST	91344	12	210B129   510	2712008010	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.27078	-118.51804	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KVA(11.050kW DC) PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER WITH 34 MODULES USING P400 OPTIMIZERS ON NEW 225A PANEL MAIN PANEL UPGRADE SHALL BE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22624	16041-10001-37382	4690 W COLORADO BLVD	90039	13	162B201    75	5593018013	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.14012	-118.27542	Changes to approved set.  Addition of new 7.5 kVA power center.  Updated single line diagram and floor plan.REF HVAC APP 16044-20000-11351	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22625	17041-10001-13435	10250 W SANTA MONICA BLVD # 1945	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Revision to approved set noted under Delta 5.  Hugo Boss Ste. 1945 at Westfield Century City	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22626	14041-20003-17367	7036 N VAN NUYS BLVD	91405	6	183B149   254	2217007018	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.1987	-118.44853	Revisions to approved set.  SLD wiring detail changes, relocation of (2) sump pumps to service equipment connection, elevator rating change, relocation of ATS, and relocation of rooftop equipment.  Approval for clouded changes only. [[[8/9/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ARE CLOUDED AND LIMITED TO RELOCATING EMERGENCY GENERATOR FROM ROOF TO OUDOOR ON 1ST FLOOR, USING MC CABLES FOR FLOOR BRANCH CIRCUITS, CHANGING UNIT FEEDER CABLES TO #6 ON SECOND FLOOR UNITS, REDUCING LIGHTING INSIDE UNITS]]]]]]]Power and energy plan check for 5 stories new built with 132 units assisted  living apartment without kitchens, central kitchen included.  2008 TITLE 24  CODE CYCLE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22627	16041-20000-07887	16501 W VENTURA BLVD Suite 410	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.1578	-118.49275	Plan check for energy only. TI to existing office on 4th floor of existing high rise building.New lighting (incl. emergency) and receptacles. 1,302 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22628	16041-20001-28688	15936 W VALLEY MEADOW PL	91436	5	162B141   270	2286024023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM			PC Approved	09/12/2016 12:00:00 AM	ADDRESS	34.13968	-118.48062	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.8 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22629	17041-20000-32093	420 E 20TH ST	90011	9	121-5A207  51	5127018011	[Q]CR-1VL-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.02826	-118.2617	Plan check for a PV2 roof-mounted PV system. System size is 12.5 kWac and consists of (1) inverter and (42) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22630	18041-10000-49088	2122 S SEPULVEDA BLVD 1-2	90025	5	126B153   653	4322019005	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM	07/15/2020 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.04106	-118.43838	Full plan check for an auto repair after fire damaged located in the haz' location. Scope includes new services, and equipment with a total area of  7186-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22631	11041-20000-08659	8000 W SUNSET BLVD 2nd Floor	90046	5	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	08/12/2011 12:00:00 AM		Permit Finaled	11/02/2011 12:00:00 AM	ADDRESS	34.09783	-118.36466	Plan check for power and energy. New 600A power to Salon Republic on 2nd floor from existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22632	16041-10000-22005	3183 W WILSHIRE BLVD 1-449	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.06196	-118.29111	RENOVATION OF T-MOBILE. UPDATE LIGHTING IN SALES FLOOR. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22633	14041-10000-29365	10 W UNIVERSAL CITY PZ 4th-5th & 7th	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM				Full plan check for Tenant improvement new soud stages and dressing room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22634	19041-10000-46456	5114 N STERN AVE	91423	4	171B153   586	2269004002	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	34.16361	-118.4344	**$0.00 FEES DUE TO ASSEMBLY BILL 1414 & SENATE BILL 1222.[EPLAN] REVISION TO 19041-10000-24724. REMOVED 125A MAIN BREAKER FROM LOAD CENTER (SEE DELTA F CHANGE). NO ADDITIONAL EQUIPMENT OR MODIFICATIONS WERE MADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22635	15041-10000-34829	6316 N FIGUEROA ST	90042	14	154-5A231 280	5493013025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.11602	-118.18359	"TI; INTERIOR TENANT IMPROVEMENT ONLY FOR A "" WABA GRILL"" RESTAURANTPLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22636	18041-10000-03093	50 N HALDEMAN ROAD	90402	11	126B129   484	4409014009	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.0412	-118.51309	**Zero dollar permit fee per SB 1222/ AB1414**Plan check for PV roof mounted system. System size: 15.2kW AC, 55 modules with 55 P370 optimizers, and 2 inverters with battery back up system(LG DC Battery) connected to 400A SFD (E) Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22637	16041-30000-37172	21050 W BURBANK BLVD	91367	3	174B105    85	2149016904	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.17311	-118.5917	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22638	16041-10000-01027	801 S BROADWAY	90014	14	127-5A209 159	5144017028	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Closed	11/28/2023 12:00:00 AM	ADDRESS	34.04375	-118.25498	PLAN CHECK FOR CORE AND SHELL OF EXISITING BUILDING RENOVATION. GUT COMPLETE BUILDING AND PROVIDE NEW ELECTRICAL DISTRIBUTION THROUGHOUT. NEW 4160 SERVICE WITH CUSTOMER SUBSTATIONS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22639	19041-20001-14019	12541 W VOSE ST	91605	2	183B161   340	2324032003	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.19857	-118.40673	INSTALLATION OF A NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.96KW DC/11.01KW AC CEC. SCOPE OF WORK INCLUDES (36) SUNPOWER 360W PV MODULES WITH INTEGRATED MICROINVERTERS, AND A 125A PV SUB PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22640	17041-10001-43510	8609 N REMICK AVE	91352	6	192B165    95	2634039016	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM			Reviewed by Supervisor	12/15/2017 12:00:00 AM	ADDRESS	34.22638	-118.40089	*expedited per applicant<<New rooftop solar system on SFD, 9.8 kW AC. Install (30) AC modules, (1) 125A load center>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22641	14041-10001-34914	745 S BROADWAY	90014	14	127-5A209  86	5144014029	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	34.04426	-118.2545	Title 24 plan check only for TI to a retail store.  Express permit already issued under 14041-10000-34914.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22642	18041-20001-15833	8756 N VANALDEN AVE	91324	12	195B121   324	2784003026	M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.22981	-118.54906	10/29/18changes to an approved set of plans.  changes to identify feeder details for sevice entrance conductors.  this is plan check only.  ((((800A 240/120V 3ph-4w service upgrade for (E) commercial manufacturing building.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22643	14041-20000-25871	19518 W VALERIO ST	91335	3	186B117   989	2116019006	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.20411	-118.5585	CENTRAL STRING INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22644	19041-20000-50148	7022 N ALABAMA AVE	91303	3	183B105   584	2138013008	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			12/05/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Closed	02/09/2021 12:00:00 AM	ADDRESS	34.19804	-118.59888	INSTALL (69) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22645	19041-20000-05935	6541 N MAMMOTH AVE	91401	2	180B153   655	2238012046	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.18969	-118.43251	PC FOR ADDITION TO EXISTING ROOFTOP PV SYSTEM FOR EXISTING SFD. ADDITION OF 3KW AC TO EXISTING 6KW AC SYSTEM. SCOPE OF WORK INCLUDES (12) REC290TP2 PV MODULES, (1) 3KW SOLIS INVERTER, AND (1) NEW 100A PV LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22646	17041-10000-38143	4842 N PLACIDIA AVE	91601	4	168B177   336	2420012018	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	12/15/2022 12:00:00 AM	ADDRESS	34.15893	-118.35584	Install new rooftop solar 10kW AC system, (35) modules with (35) power optimizers, (1) Inverter	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22647	16041-10000-43118	9505 N SEPULVEDA BLVD	91343	7	198B145    35	2656011027	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.24325	-118.4678	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total area:28100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22648	16041-10000-42685	523 W 6TH ST #300	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	Plan check Title 24 only addition of existing space T.I. office in a high-rise building. Total area: 2,870 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22649	17041-30000-19013	2600 W SAN MARINO ST	90006	1	132A201   280	5076006025	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Apartment			06/06/2017 12:00:00 AM			PC Info Complete	06/06/2018 12:00:00 AM	ADDRESS	34.05492	-118.28441	Plan chek for new 6 story appartment building 31 units appartment. Total area: 19,153 sq ft. 7 typical units.B# 16010-10000-03987	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22650	15041-10000-32066	15509 W VINCENNES ST	91343	7	198B145    87	2656015015	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.24106	-118.47005	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(15) REC SOLAR MODULES(15) POWER OPTIMIZERS (1) SOLAREDGE INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22651	15041-10000-25943	2002 W SLAUSON AVE	90047	8	105B189    20	6001001900	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	33.98891	-118.31398	PC FOR POWER AND  ENERGY TO A NEW (2) STORY COMMERCIAL BLDG. 600 AMP SERVICE,PV SYSTEM SHALL BE SUBMITTED UNDER SEPARATE APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22652	13041-10000-11289	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	FA FOR LAX. ADDING PANEL DETECTION FENWAL DEVICES TO VIDEO WALLS. preaction for tower	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22653	19041-20000-14375	6948 N FIRMAMENT AVE	91406	6	183B141   489	2234002002	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.19722	-118.47261	Plan check for battery back up system in to existing PV System, install battery 2 Power Wall 2.0(13.5KWh)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22654	18041-10001-10166	18145 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.26469	-118.52687	PC FOR LOST SET. SCOPE HAS MINOR CHANGES THAT INCLUDE REUSING EXISTING POWER DIST. SYSTEM. PERMIT PAID UNDER MASTER. THIS IS PLAN CHECK ONLY!Plan check for T24 only, Tenant Improvement to existing restaurant.  Install (2) new panels for lightings and power. Total area: 1,881sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22655	15041-20000-10330	9301 N TAMPA AVE FC-6	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	08/15/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for energy only. Project site is an existing commercial space. Project scope is a tenant improvement which includes power and lighting. Total lighting area = 151 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22656	13041-10000-11425	1132 N VERMONT AVE	90029	13	144B197   506	5542029039	C2-2, P-1, [Q]C2-2D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	05/02/2013 12:00:00 AM	ADDRESS	34.09184	-118.29154	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ON A TENANT IMPROVEMENT (YOGURTLAND). 1056 SQUARE FEET, LOAD < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22657	14041-20000-23622	5168 W MELROSE AVE	90004	4	141B193   612	5522007026	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	PIN	34.08332684	-118.31320919	TI IN (E) RETAIL SPACE IN AN (E) URM HOTEL. CONVERTING THE RETAIL SPACE TO A LOUNGE BAR. ADDING A NEW MEZZANINE FOR EQUIPMENT STORAGE INSIDE BAR AREA.  A2 OCCUPANCY EXCEEDING 100 OCCUPANT LOAD.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22658	18041-10000-13771	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Info Complete	04/16/2018 12:00:00 AM	ADDRESS	34.24205	-118.59773	MODIFICATION OF A FEE THRU TARIF PV SYSTEM HAS WHICH LACKING PROBLEMS WITH AUTOMATIC RAPID SHUTDOWN DEVICES. INSTALLATION OF COMBINNER BOXES WITH RAPID SHUTDOWN CONTROL CIRUITRY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22659	17041-10000-41745	1805 E INDUSTRIAL ST	90021	14	124-5A217 122	5164012022	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Issued	11/17/2017 12:00:00 AM	ADDRESS	34.03596	-118.23418	Remove Outdoor HID fixtures and replace with new LED fixures. T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22660	14041-20000-16864	1463 W 3RD ST	90026	13	133-5A207 247	5153027004	C2-1	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	PIN	34.05935752	-118.26357841	new 800amp service.  All load are to be future.  existing commercial building single story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22661	11041-10000-02849	19950 W RINALDI ST	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.27535	-118.56939	T.I. TITLE 24.  MEDICAL OFFICE CONVERTING TO PHARMACY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22662	19041-20000-18503	606 N WESTERN AVE	90004	13	141B193   892	5521002005	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Apartment			05/16/2019 12:00:00 AM			PC Info Complete	08/08/2019 12:00:00 AM	ADDRESS	34.08193	-118.30887	New 63-unit mixed-use building with (2) commercial spaces.  2000A 208Y/120V 3ph 4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22663	14041-20000-34362	7083 W HOLLYWOOD BLVD #620	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.10173	-118.34439	T.I. to existing building on 6th floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22664	19041-20000-49571	14527 W KILLION ST #1-3	91411	4	174B149   937	2249001008	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM			PC Approved	02/07/2020 12:00:00 AM	ADDRESS	34.17137	-118.44979	FULL PLAN CHECK FOR (4) PANELS, (48) BRANCH CIRCUITS, (6) 5.1-20 KVA EQUIPMENTS.THIS PERMIT IS UNDER BUILDING PERMIT 17010-20000-02116SECOND PERMIT 19041-20000-49568 UNDER BUILDING PERMIT17010-20000-02117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22665	12041-10000-06958	3021 S FIGUEROA ST	90007	9	121-5A203 221	5123010027	R3-1-O, [Q]C2-1VL-O	South Los Angeles	South Central Los Angeles			2247.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.02477	-118.27851	T.I. FOR (E) RESTAURANT : INTERIOR NON-BR PARTITIONS, NEW H.C. RESTROOM, ADD ROOF MOUNT PLATFORM FOR (2) 150LBS CONDENSER UNITS, INSTALL NEW 5' X 8' SKYLIGHT.Plan-check for T-24 lighting and emergency ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22666	14041-10000-06102	4818 E STRATFORD ROAD	90042	14	156A223    31	5476019002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1834.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Expired	05/05/2016 12:00:00 AM	ADDRESS	34.12374	-118.20982	PV1,INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.6-OUTD-S-US-Z-A(19) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22667	16041-20000-40610	13758 1/2 W ROSCOE BLVD	91402	6	192B153   773	2213016003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.22139	-118.43316	Plan check for energy only. TI to commercial space - donut shop. New lighting (incl. emergency). 780sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22668	10041-10000-00877	8500 W BEVERLY BLVD #621	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	01/21/2010 12:00:00 AM		Permit Finaled	03/17/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT - PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22669	14041-10001-08640	6740 N AGNES AVE	91606	2	180B165    89	2322010007	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.19323	-118.39526	EXPEDITED RSES PLAN CHEK PER APPLICANT REQUEST.{{PV1, INSTALL 6.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U(27) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22670	14041-20000-22170	12664 N GLENOAKS BLVD	91342	7	219B153    64	2508010002	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.30053	-118.44027	PV1.  Install 4.25 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22671	10041-10001-03134	701 N STONE CANYON ROAD CENTRAL-BLDG	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	06/01/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	REVISED SINGLE LINE DIAGRAM TO SHOW THAT FROM THE EMERGENCY GENERATOR THERE IS NO NEUTRAL CONDUCTORS AND THAT THE ATS REMAIN 3-POLE AS THERE ISN'T A SEPARATE DERIVED SYSTEM. EXCEPT AT TRANSFORMER EKL WHICH SUPPLIES PANEL EKL   (((((((((((((((UPGRADE TO THE CENTRAL PLANT BUILDING AT THE BEL-AIR HOTEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22672	16041-20001-32955	1932-1936 S PONTIUS AVE	90025	5	126B153   339	4323025005	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.04342	-118.44132	5/15/17changes to an approved set of plans.  changes include recalculation of energy compliance forms and plans to reflect field conditions.  .  this is plan check only.  TI to (E) warehouse space.  New 400 A 240V 3 phase service.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22673	15041-20000-36464	15406 W CABRITO ROAD	91406	6	189B145   277	2654039015	M1-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.21657	-118.46861	Full PC for power and energy. Scope includes Fire damage repair to remove and replace existing panels and main switchboard, and adding new lights to existing units. New 800A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22674	12041-10000-29868	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	DODGER STADIUM. FULL PLAN CHECK FOR ENERGY AND POWER. NEW AND REMODELED TOILETS FOR THE STADIUM. APPLICANT TO SUBMIT SEPARATE FIRE ALARM PLANS BY FIRE ALARM VARIANCE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22675	06041-10011-09913	1633 N LA BREA AVE	90046		147B181   287	5548008010	C4-1VL-SN		Hollywood	Hollywood Hills West			Electrical	Electrical	Apartment			09/09/2011 12:00:00 AM			PC Info Complete	09/09/2011 12:00:00 AM	ADDRESS	34.10058	-118.34527	DELTA 14 REVISIONS TO APPROVED SET OF PLANS- CHANGES TO INTERIOR LIGHTING SYSTEM; NEW FACADE LIGHTING  ; INCREASE BY ONE SET OF CONDUCTORS FOR THE FEEDERS TO THE UNIT PANELBOARDS((((((((((((((((((((((((((((( SERVICE RATED DISCONNECT FOR FIRE PUMP IN ELECTRICAL ROOM. 2 HOUR RATED CABLE FROM DISCONNECT TO FIRE PUMP M.ZANDI EPC)))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22676	14041-10000-06075	13581 W DESMOND ST	91331	7	210B157    80	2523004035	M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.27482	-118.42866	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  12516 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22677	12041-10000-16624	714 W OLYMPIC BLVD	90015	9	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.04454	-118.26341	Change of use from Retail to Bank.  New 200Amp Service, Panels, Transformer, and Lighting.  Load is less than 400 Amps and Occupancy Load is less than 35 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22678	13041-20000-26159	8811 N NORWICH AVE	91343	6	195B145   368	2653008005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.23054	-118.46023	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.25 KW. 21 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22679	15041-20000-06425	12744 N SAN FERNANDO ROAD Bldg3 #B	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for T-24 only. Bath room T.I. with total area: 100 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22680	16041-20000-15073	1225 W JAMES M. WOOD BLVD	90017	1	129A205    78	5143002019	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.04886	-118.26841	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP AND 29 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22681	14041-10000-33753	15036 W HARTLAND ST	91405	6	183B145   666	2220019005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.19517	-118.46103	PV1 5KW AC roof-mounted system including (17) Sunpower SPR32NE-WHT-D modules and (1) Power PV1-5000-OUTD inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22682	16041-10000-02833	250 E 1ST ST	90012	14	130-5A213 150	5161016014	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Expired	04/23/2018 12:00:00 AM	ADDRESS	34.05038	-118.24114	Fire alarm replacement system for a HIGH RISE BUILDING ; Scope includes (1) new fire alarm system, (7) control panels, (1) communication panel, and (301) fire alarm device.  All exsiting fire alarm devices will be reconnected to the new fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22683	19041-20003-06153	10236 W MOSSY ROCK CIR	90077	5	156B153   196	4382025***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.12205	-118.44372	6/18/2019changers to an approved set of plans.  changes to reflect field conditions.  installation of pv solar ready panel.this is plan check only.  ((((Plan check for PV roof mounted system, system size: 11.22KW DC with 34 PV Modules and 1 inverter(11.4KW) connected to 225A panel.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22684	11041-10000-09038	2500 W 6TH ST 1st & 2nd-floors	90057	1	133-5A203  54	5141006001	C2-2	Central	Westlake	MacArthur Park		2088.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	08/12/2011 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.06157	-118.27977	ALTERATIONS IN EXISTING 8-STORIES STORAGE BUILDING: NEW 400A distribution board to refeed existing panelboards on the upperfloors; refeeding other panelboards	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22685	17041-20000-27570	333 S HOPE ST 37th Floor-Restrooms	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 only. Project site is the restrooms on the 37th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 997 sq. ft.Note: Building permit has been issued under 17016-10000-16776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22686	14041-10000-17682	520 S GRAND AVE 2nd floor	90013	14	129A211     2	5149030003	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	PIN	34.0492823	-118.25370894	PLAN CHECK FOR POWER AND ENERGY. (e) office of high rise  building. BLDG#14016-10-12499:  FULL FLOOR T.I. ON 2ND FLR (50,590 S.F.) NON-STRUCTURAL WORK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22687	19041-10000-21071	21019-21021 W OSBORNE ST	91304	3	195B105    43	2779048007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			Reviewed by Supervisor	06/27/2019 12:00:00 AM	ADDRESS	34.23316	-118.59132	(Assign to Edwin or John per Mr. Nabil request)PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 350 MODULES (Q-PEAK 390), 175 OPTIMIZERS (P850 ), 2 INVERTERS ( SE 20K) AND 1 INVERTERS ( SE 66.6K). SYSTEM SIZE IS 106.6KWac AND 136.5KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22688	19041-20000-37911	350 S GRAND AVE 37th Floor-Rest Rooms	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 Energy only 2 Restroom in 37th Floor Tenant Improvement. Total area: 727 sq ft.B#19016-40000-23030	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22689	13041-10000-01979	14555 W OSBORNE ST	91402	7	195B149    97	2639007021	R4-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Apartment			01/25/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Issued	03/01/2013 12:00:00 AM	ADDRESS	34.23325	-118.44944	Replacement and upgrade of fire alarm system for 8 story apartment complex. total number of 427 devices and 2 panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22690	18041-20000-16360	1633 S ABBOT KINNEY BLVD	90291	11	108B145  1569	4241036023	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM			PC Approved	05/03/2018 12:00:00 AM	ADDRESS	33.98964	-118.46313	Plan check for energy only in existing restaurant T.I. Total area: 747 sq ft.B#17014-10000-03502	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22691	15041-10000-43206	737 S BERENDO ST	90005	10	132B197   333	5094009016	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			12/22/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.05872	-118.29429	PV2, ROOF MOUNTED SOLAR SYSTEM TO A TENANT IN AN APARTMENT BUILDING.  (8) MODULES AND (1) CENTRAL INVERTER-3KW-AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22692	11041-10000-14012	12719 W WASHINGTON PL	90066	11	111B153  1186	4236020019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.00	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	33.99706	-118.43548	INTERIOR TENANT IMPROVEMENT; CHANGE OF USE TO CHILD CARE CENTER; UPDATE OF STAIR, RAMP AND BATHROOM TO BE PER TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22693	19041-10001-14190	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Issued	12/30/2019 12:00:00 AM	ADDRESS	34.06086	-118.27891	Change to an approved set by adding new panels to one of the three services. New ckts also added. All load, fault current, equipment bracing, and voltage drop added. Lighting also added. All changes under delta-2 only. (((POWER AND ENERGY PLAN CHECK FOR A HISTORIC BUILDING TI. SCOPE INCLUDES 3 EXISTING SERVICES ( MSA 2000A 480/277, MS 2500 208/120 AND MSB 2000 480/277), NEW PANELS, EQUIPMENT AND  LIGHTING. TOTAL AFFECTED AREA   14244 SF)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22694	16041-20000-08628	700 S FLOWER ST Suite 560	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 990 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22695	15041-10000-03433	333 S HOPE ST C-140	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	Energy plan check for an office T.I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22696	11041-10000-27196	6701 S CENTER DR 8TH FLOOR	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM			PC Approved	12/21/2011 12:00:00 AM	PIN	33.97892163	-118.39376065	Plan check T24Energy/Emergency for office TI on the 8th floor. Existing permit under #11041-90000-25809	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22697	15041-10000-40691	677 N SWARTHMORE AVE	90272	11	126B125   447	4412012017	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.0423	-118.52738	PV1, INSTALL 8.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(28) MODULES: SILEVO TRIEX U290 BLACK(1) INVERTER: FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22698	19041-10000-23227	1451 N GARDNER ST	90046	4	147B177  1036	5550025013	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.0977	-118.35305	Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22699	13041-10000-26469	2049 S CENTURY PARK EAST 8TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE-24 ONLY PLAN CHECK; TI FOR OPEN OFFICE AREA IN HIGH-RISE BUIILDING. SCOPE OF WORKING IS FOR AN 150 OPEN OFFICE/WAITING AREA. NO EMERGENCY LIGHTING/EXIT SIGNS INVOLVED. WORK DONE ON THE 8TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22700	17041-10000-22852	4103 W ADAMS BLVD	90018	10	123B185   628	5059008017	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.02	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.03276	-118.32981	PLAN CHECK FOR T24 ONLY - SCOPE INCLUDES REPLACE EXISTING FIXTURES WITH LED FIXTURES - TOTAL AFFECTED AREA 5690 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22701	13041-10000-15154	1200 S UNION AVE	90015	1	129A203   414	5137029029	R4-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Apartment			06/10/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Expired	10/15/2015 12:00:00 AM	ADDRESS	34.04602	-118.27597	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. NEW PANEL AND NEW DEVICES.  THREE STORY BUILDING. NO PARKING INCLUDED IN SCOPE OF WORK. 312 DEVICES AND 1 FIRE ALARM CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22702	14041-10001-29651	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008023	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC for T24 for two indoor neon sign lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22703	16041-20001-33620	4438 W DON MIGUEL DR	90008	8	114B181   725	5027003005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.00575	-118.35161	RSES expedited plan check per applicant request.  (((PV1.  Install 15.2 kW AC (12.96 kW DC) roof mounted utility interactive PV system.  (54) modules with (2) 7.6 kW transformerless inverters with power optimizers.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22704	11041-20000-21895	808 W 58TH ST	90037	9	108B197  1393	5001015032	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	33.98934	-118.28723	PLAN CHECK POWER AND ENERGY FOR TI OF EXISTING MEDICAL BUILDING. TWO EXISTING 600A AND 1000A SERVICES SUPPLYING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22705	16041-20002-45787	20908 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.21969	-118.58915	10/16/2017changes to an approved set of plans.  changes to match field conditions, noted delta 3.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22706	11041-10001-09157	11818 W DOROTHY ST 1-26	90049		129B145   285	4265017049	R3-1		Brentwood - Pacific Palisades				Electrical	Electrical	Apartment			11/09/2011 12:00:00 AM			PC Info Complete	11/09/2011 12:00:00 AM	ADDRESS	34.05151	-118.4671	NEW 4 STORY 26 UNIT APARTMENT BUILDING.  <<<<FIRE ALARM REQ. VARIANCE WILL BE SUBMITTED TO SEPERATE THE PLANS>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22707	19041-20000-10385	1990 S BUNDY DR ste 400	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.03419	-118.45559	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22708	12041-10001-28200	6333 W SUNSET BLVD	90028	13, 4	147B169   681	5561010018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00, 1943.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			PC Info Complete	05/20/2013 12:00:00 AM	ADDRESS	34.09817	-118.32753	Changes from previously approved plans.  Changes in clude general and emergency indoor lighting.  Plan check for energy only.  Note: Permit is under the previous application.three lights been added and plan restamped by Nabil.  Tis plan check only for title 24.  Permit is existing under seperate nnumber*****TENANT IMPROVEMENT TO EXISTING RESTAURANT. NEW RESTROOM, PARTITIONS, REPLACE KITCHEN, MILLWORK AND FINISHES.PLAN CHK IS FOR TITLE 24 ONLY*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22709	19041-10000-42799	3403-3407 S CRENSHAW BLVD	90016	10	120B185   901	5046001046	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	04/14/2020 12:00:00 AM		Issued	04/14/2020 12:00:00 AM	ADDRESS	34.02535	-118.33529	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW 1200A (120/208 3P, 4W) THAT FEEDS A 1200A DISTRIBUTION BOARD THAT SUBFEEDS SEVEN SUBPANELS. TOTAL AFFECTED AREA IS 11750 SQFT, OUTDOOR LIGHTING ONLY. NOTE THIS IS A CORN AND SHELL ONLY, INDOOR LIGHTING WILL BE COVERED AS A TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22710	14041-20000-33302	10805 W STALLION RANCH ROAD	91040	7	204B173   495	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Expired	02/23/2017 12:00:00 AM	ADDRESS	34.25609	-118.36578	PV1 SFD TOTAL SYSTEM SIZE 12KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. THIS IS A GROUND MOUNTED PV SYSTEM. GROUNDMOUNTED BUILDING P# :14020-20000-03169	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22711	17041-10000-24567	501 S BOYLE AVE	90033	14	126A221    18	5174002020	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.04125	-118.2198	PC FOR A TI.  CHANGE OF USE ON 1ST FLOOR FROM ADULT LEARNING CENTER TO PUBLIC  ELEMENTARY SCHOOL.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA 1026 SQ.FTPERMIT PULLED UNDER 17041-40000-20164PLAN CHECK ONLY!!!BUILDING #16016-10000-27615	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22712	15041-10000-23954	748 E 50TH ST	90011	9	111A207   213	5108013007	R2-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	33.99746	-118.2619	PV 1 MOUNTING ON EXISTING ROOF. TOTAL SYSTEM SIZE 6.625 KW.(25) MODULES KYOCERA #KU2656ZPA(1) INVERTER ABB# #PVI-6.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22713	18041-10000-28720	10601 W WASHINGTON BLVD	90232	5	117B165   262	4208009049	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.0175	-118.40491	"**** SEE APPLICATION COMMENTS*****PC FOR FIRST TIME TENANT FOR A RESTAURANT ""JIMMY JONES""SCOPE INCLUDES NEW PANEL, CIRUCUITS, EQUIPMNET AND LIGHTS. TOTAL AFFECTED AREA  1274 SQ. FTFIRST TENANT FOR DISTRIBUTION BOAR RRMSA (INSPECTOR TO VERIFY)B#18016-10000-24206"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22714	15041-20001-33054	801 S GRAND AVE Suite 600	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM			PC Approved	10/26/2015 12:00:00 AM	ADDRESS	34.04581	-118.25842	Changes to an approved set. Changes made under delta 1. Replacing lighting fixtures. ((Plan check for Title 24 only. Project site is the 6th floor of an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 17,816 sq. ft.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22715	19041-10002-04929	23037 W OXNARD ST	91367	3	177B097   453	2039008026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.17934	-118.62886	EXPEDITE PER CUSTOMER REQUESTPV1 . NEW ROOFTOP SOLAR SYSTEM CONSIST OF 38 MODULES (SUNSPARK TECH SST-300W) AND 38 MICROINVERTERS (ENPHASE IQ7-PLUS-60-2-US). SYSTEM SIZE IS 11.4KWdc and 10.08KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22716	18041-10000-16739	7201 S SAN PEDRO ST	90003	9	102B205   874	6022009029	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	33.97452	-118.26972	Plan check for Energy, T24 only, TI on existing Retail space. Install new lights and receptacles. Total area: 1687 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22717	11041-10000-25135	1700 S WOOSTER ST	90035	5	129B169   992	4303008035	R1-1	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2011 12:00:00 AM	01/04/2012 12:00:00 AM		Permit Finaled	01/11/2012 12:00:00 AM	ADDRESS	34.04828	-118.3834	PLAN CHECK 5.88KW ROOF MOUNTED TRANSFORMERLESS INVERTER PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22718	14041-20000-03161	7808 S STANFORD AVE	90001	9	099B205   569	6023031016	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	33.96817	-118.26281	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING SINGLE TRANSFORMERLESS INVERTER NONSTNADARD PLAN. USING 6 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22719	18041-20000-06642	7224 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	33.97406	-118.2913	PLAN CHECK FOR POWER AND ENERGY FOR - T. I. TO COMM. BLDG  - CONNECTED LOAD EXCEEDS 400A WITH TOTAL AFFECTED OF 2166 SQ. FT. SCOPE OF WORK INCLUDES PANEL LB AND DB AS NEW CONNECTED LOAD, PANEL LA AND LC AS RELOCATED LOADS, AND PANEL LD AND HD WITH PARTIAL CONNECTED LOAD NOTED AS (N)CIRCUITS AND LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22720	18041-20000-18205	1155 S LA JOLLA AVE	90035	5	132B173   964	5087009005	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.05557	-118.37319	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (18) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22721	12041-10000-21834	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	"NEW TENANT ""PIER 1"" IN THE MALL. PLAN CHECK FOR POWER & ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22722	17041-20000-13854	19126 W PALA MESA PL	91326	12	213B121   700	2822035010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.27785	-118.55051	PV1.  Install roof mounted grid tied PV system sized 14.3kW, interconnect with MSP.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22723	12041-10000-15683	5838 W GREGORY AVE	90038	13	141B189    64	5534031007	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Apartment			07/06/2012 12:00:00 AM	07/06/2012 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.08609	-118.32353	Plan check for fire sprinkler monitoring system. 7 unit apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22724	14041-20000-13290	10509 N COLLETT AVE	91344	12	207B141   708	2668006016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.26143	-118.48384	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 864 WATTS. USING MICROINVERTER ENPHASE M215. USING STNADARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22725	16041-20001-40170	24559 W INDIAN HILL LANE	91307	12	186B085    84	2031013046	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	11/22/2016 12:00:00 AM	ADDRESS	34.20511	-118.65794	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.2 kWac and consists of (2) inverters, (51) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22726	14041-20001-14930	9301 N TAMPA AVE kiosk 5546	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM			PC Approved	07/21/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for energy only. New kiosk in Northridge mall. Installation of new lighting in kiosk and in a separate existing storage room.  Permit under seperate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22727	15041-20001-30425	4217 N WOODCLIFF ROAD	91403	4	165A145   107	2281006005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.14709	-118.46753	Expedite fees only.    Installation of new roof mounted solar PV array on existing sigle family home.  Total system size = 6 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22728	18041-10000-35887	22108 W LEADWELL ST	91303	3	186B101   789	2023011010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.2036	-118.60847	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SE5000 - HUS) WITH 18 PV PANELS USING (P320) OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22729	13041-20000-33988	5333 W ZOO DR	90027	4	162B197     2	5593002905	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.14867	-118.28623	T24 FOR EXISTING ZOO. SCOPE OF WORK AROUND JAGUAR CAGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22730	19041-10000-32967	9300 N MASON AVE	91311	12	198B109    98	2748022060	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.23931	-118.57958	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22731	12041-10000-19468	6060 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	33.94301	-118.39128	PLAN CHECK FOR LAWA RECORD RETENTION CENTER FIRE ALARM SYSTEM. (SPRINKLER MONITORING SYSTEM)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22732	13041-10000-21318	250 E 1ST ST 5TH-7TH-FLOORS	90012	14	130-5A213 150	5161016014	[Q]C2-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.05038	-118.24114	REMODELING OF OFFICES ON THE 5TH THRU 7TH FLOORS OF A HIGH RISE BUILDINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22733	14041-10000-03325	907 S SHENANDOAH ST	90035	5	132B169   121	4333012024	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			02/05/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.06063	-118.3816	PLANCHECK FOR POWER AND ENERGY. NEW 4-STORY 6-UNIT APARTMENT WITH BASEMENT GARAGE.  DESIGN BUILD BY CONTRACTOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22734	19041-10000-03618	654 E VERNON AVE	90291	11	111B145  1229	4239003018	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	33.99767	-118.46818	PV1 with ESS, Install 7.6 kW AC/ 6.175 kW DC roof-mounted solar array, with 13.5 kWh ESS, interconnect with 200A service panel. (19) modules, (1) 7.6 kW inverter, (1) 200A load center, (1) 13.5 kWh ESS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22735	16041-10004-02231	6002 S ALVISO AVE	90043	8	105B181   575	4004021001	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	33.98516	-118.34376	Plan check for T24 only per inspection request, permit is issued under master #16041-70000-02231. This plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22736	11041-10000-15056	1781 E 1ST ST	90033	14	129A221   219	5174013905	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.40	Electrical	Electrical	Apartment			07/19/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.04739	-118.22035	New fire alarm for a new 4 story apartment complex.  One fire alarm panel.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22737	18041-20001-21474	13224 W FERNMONT ST	91342	7	222B157   295	2512006042	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2018 12:00:00 AM			PC Approved	06/20/2018 12:00:00 AM	ADDRESS	34.30504	-118.42122	PV1.  Installation of (12) modules and (1) 3kW rated central inverter to add to an (E) PV system for a total combined system size of 9.120 kW DC.  Plan check only - master permit obtained online.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22738	13041-20001-22228	2987 N INGLEDALE TER	90039	13	154-5A207 375	5435030052	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.11633	-118.26569	(((EXPEDITE FEE APPLICATION)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW USING 18 MODULES WITH POWER OPTIMIZERS. TRANSFORMERLESS SYSTEM. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22739	15041-20000-15657	8001 N VENTURA CANYON AVE	91402	6	189B157   306	2213019040	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.21649	-118.42885	Plan check for power and Title-24 (energy).  Total area = 5,153 sq. ft.  Remodel of three sections of existing two story medical office building.  One new panel + lighting, recepticles, and HVAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22740	19041-10000-42140	1546 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   368	5021005902	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.01067	-118.30503	PLAN CHECK FOR POWER ONLY - PLAN CHECK INCLUDES 800A DISTRIBUTION SERVICE PANEL   SUPPLYING  NEW CAR CHARGERS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22741	15041-10000-04281	8700 S METTLER ST	90003	9	097-5A207 401	6041019016	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	33.95908	-118.26644	Title 24 plan check only.  Total area = 2,200 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22742	11041-10000-13923	3377 W OLYMPIC BLVD	90019	10	129B193   285	5081033011	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.0528	-118.31175	Existing restaurant T.I.  Upgrading service from 400 Amps to 600 Amps.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22743	17041-10000-14358	2108-2110 W SUNSET BLVD	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Info Complete	05/01/2017 12:00:00 AM	PIN	34.07718395	-118.26405818	Title 24 plan check.  T.I. to corridor and mezzanine in existing commercial building.  Total area = 1,260 sq. ft.     Building permit #16016-10004-04903	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22744	13041-20000-24680	980 N WESTERN AVE STE G-A-H	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM			PC Approved	09/09/2013 12:00:00 AM	ADDRESS	33.7515	-118.30878	Plan check for energy only. Subway #3834. Low rise commercial. Suite G.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22745	18041-10000-09125	13003 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	34.1457	-118.41619	FULL PC FOR A CORE AND SHELL,  MULTI-TENANT BUILDING. SCOPE OF WORK INCLUDES NEW SERVICE UPGRADE TO 120/208, 3PH, 1600AMPS. NEW OUTDOOR LIGHTING AND RECEPTACLES. TOTAL OUTDOOR  SQ. FT. 10992.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22746	10041-20000-11830	2121 S AVENUE OF THE STARS 7th Floor	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	07/29/2010 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check T-24 Energy general lighting for office spaces on 7th Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22747	19041-10001-26933	3912 S GRAND AVE	90037	9	117A203   277	5122046028	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	02/25/2020 12:00:00 AM		Issued	02/25/2020 12:00:00 AM	ADDRESS	34.01322	-118.28039	Changes to an approved set of plans, changes include the installation of a back up generator and ATS rated at 800 amp. Note changes on clouded areas. ________________________________________________________________________PC FOR POWER ONLY. SCOPE INCLUDES A NEW 300KW TEMPORARY GENERATOR. TEMPORARY POWER FOR A FREE STANDING SIGN.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22748	19041-20000-22443	2693 N CARMAR DR pv1	90046	4	153B169    28	5565037024	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.11931	-118.38119	permit fee $0.00 by state senate bill no. 1222pv1Install roof mounted PV System size:  18.23KW DC, 18.04KW AC CECwith 54 PV Modules and 2 inverters(7.6KW) interconnected with MSP 400A .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22749	18041-10000-02890	18630 W DEARBORN ST	91324	12	198B121   675	2763012006	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.2372	-118.53929	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 6.09KWDC / 5.0 KWACSCOPE INCLUDES 21 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22750	18041-10001-15643	14640 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM			PC Approved	04/04/2019 12:00:00 AM	ADDRESS	34.22128	-118.45128	First time tenant for a future Starbuck's. Outdoor T-24 LTG was checked and permit was issued under 18041-10000-15643. Per inspector Koski, Electrical Plan Check is require for the new stand alone 400 Amp, 120V/208 Service core & shell only. BUILDING PERMIT # 18010-10000-01625	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22751	11041-20000-16342	8550 N BALBOA BLVD #295	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.22649	-118.5024	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING EXISTING 2ND FLOOR OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22752	16041-20001-12918	12609 N EL ORO WAY	91344	12	219B133   177	2608005007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.29941	-118.50698	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. PV addition system size is 3 kWac and consists (1) inverter and (8) modules. Total system size 9 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22753	19041-20000-23010	24210 W CARIS ST	91367	3	177B089   556	2045002016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.1802	-118.65415	Plan check for PV roof mounted system, PV system size: 11.5KW DC, 10.64KW AC CEC with 35 PV Modules and 35 microinverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22754	16041-20000-17729	6064 N COLFAX AVE	91606	2	177B169   601	2334014038	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.18125	-118.3876	INSTALLATION OF A NEW FIREALARM SYSTEM. 1 FACP AND 32 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22755	13041-20001-02426	10319 N LEOLANG AVE PV1	91040	2	204B193   572	2559008013	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.25658	-118.30605	PERMIT TO BE ISSUED UNDER THIS APPLICATION FOR THE DIFFERENCE BETWEEN ORIGINAL PERMIT UNDER 13041-20000-02426 AND THE APPROVED SET OF PLANS. supp application for pc only. permit already issued under original application. system contains enphase microinverter m215. requires pc. INSTALL ROOF MOUNTED PHOTOVOLTAIC SYSTEM 4.8KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22756	11041-10000-15543	2209 E I ST	90744	15	033B217   494	7428023050	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Expired	08/17/2018 12:00:00 AM	ADDRESS	33.78296	-118.2342	install a 480v switchrack and pumps in a hazardous location.  plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22757	12041-10000-29592	10031 N WYSTONE AVE	91324	12	204B121   488	2729004015	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	01/02/2013 12:00:00 AM	ADDRESS	34.25295	-118.54717	New 7.92 kw roof mounted PV1 for a single family	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22758	13041-10001-05019	3349 S OAKHURST AVE	90034	5	123B165  1176	4311016010	R1-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.02996	-118.39774	Modification to approved set.  Modules changed from REC 245 PE BLK to REC 250 PE BLK.Original Work Description: PV1 2.16 KW {10 MODULES: REC 245 PE BLK} {MICROINVERTER: ENPHASE M215-60-2LL-S22}2 STORY HOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22759	17041-10000-13841	9265 N GLENOAKS BLVD	91352	6	198B173    97	2408034037	M2-1-CUGU, M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.23722	-118.37455	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  16200 SQ FT. OUTDOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22760	14041-20000-10656	23900 W STAGG ST	91304	12	189B089   447	2027040033	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.21056	-118.64943	PV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL TRANSFORMERLESS INVERTER STANDARD PLAN. SYSTEM SIZE: 9.25 KW DC.(37) CANADIAN SOLAR CSP 250(2) POWER ONE  PVI 3.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22761	14041-10000-05326	944 E SLAUSON AVE	90001	9	108B209  1586	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	33.98915	-118.25799	plan chk for2000A meter section with 1600A main section ( service is 1600A)permitted plans (13041-10000-11574) WITH INCORRECT ADDRESS 5849 S CENTRAL AVE HAD THE UGPS and service as existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22762	17041-20000-30126	5422 N KATHERINE AVE	91401	4	171B153    32	2245024020	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.16937	-118.44311	permit fee $0.00 by state senate bill no. 1222Plan check for solar pv system with AC coupled battery backup system.(1) 10kW ungrounded inverter. (36) 325W pv modules. (36) 400W power optimizers.(2) 5kW Tesla Powerwall 2's.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22763	09041-10001-04821	410 S MAIN ST	90013	14	129A213   182	5148008002	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM			PC Approved	04/04/2011 12:00:00 AM	ADDRESS	34.04767	-118.2474	tenant improvement in existing restaurantplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22764	13041-10000-30512	8101 W SUNSET BLVD	90046	4	147B177   989	5555031001	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Expired	11/25/2015 12:00:00 AM	ADDRESS	34.09816	-118.36529	PLAN CHECK FOR ADDITION OF A 2.74KVA  NEW DIESEL TURBINE PUMP IN A EXISTING PANEL ON A HAZARDOUS ZONE. SERVICE AND PANELS EXISTING. SEAL OFFS PROVIDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22765	18041-20000-35426	11806 N MARIPOSA BAY LANE	91326	12	216B113   174	2701035053	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.28538	-118.5661	Installation of 56 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22766	15041-20000-13832	5166 N AVENIDA HACIENDA	91356	3	171B125   434	2161023004	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2015 12:00:00 AM			PC Info Complete	06/19/2015 12:00:00 AM	ADDRESS	34.16517	-118.5335	Plan check for new family dwelling unit (600A Service)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22767	10041-10001-17720	6355 N DE SOTO AVE Bldg 1	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.18639	-118.58869	REVISIONS TO PERMITTED SET OF PLANS-NEW PANEL  RD  WITH CIRCUITS; NEW LUMINAIRE -TITLE 24 FORMS CHANGED;ELEV RATING FROM 25HP TO 3OHP-FEEDERS/CONDUIT REVISED ATTACHED TO THE REVISED PLANS ARE A LIST OF THE CHANGES((((((((New 2-story Clubhouse for 4-story ___ -unit apartment  bldg( separate application )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22768	18041-10001-26391	9045 W ORIOLE WAY	90069	4	147B169   770	5560004013	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	Yes	1943.00	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM			PC Approved	07/27/2018 12:00:00 AM	ADDRESS	34.09694	-118.38765	EXPEDITED PER APPLICANTS REQUEST. ENERGY STORAGE SYSTEM (6) LG CHEM 10H  + SYSTEM SIZE: 28.86KW DC , PV1. ROOFMOUNTED SOLAR SYSTEM.  (78) SILFAB SLG370M , (3) STOREDGE 7600	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22769	11041-20000-12818	4505 W JEFFERSON BLVD	90016	10	120B181   708	5057022030	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	07/25/2011 12:00:00 AM	ADDRESS	34.02568	-118.34523	Plan check for new 600A service, distribution board, and new panels only. No new load installed. Remove existing 200A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22770	13041-10000-03303	9343 N ALDEA AVE	91325	12	198B133   194	2692004005	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.24067	-118.50974	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. UPGRADE HOUSE PANEL. 46 UNITS PANELS, 11.27KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22771	10041-10000-03073	10936 W MAGNOLIA AVE	91601	4	171B173  1379	2419001043	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			02/22/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	05/05/2010 12:00:00 AM	ADDRESS	34.16469	-118.36943	TENANT IMPROVEMENT -CHANGE FROM ICE CREAM SHOP TO YOGURTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22772	13041-10000-03220	153 N GLENDALE BLVD 1-45	90026	13	135A209   289	5159015009	C2-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Apartment			02/07/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.06346	-118.26018	NEW FIRE ALARM ON 45 UNIT APARTMENT. THREE STORY AND ROOF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22773	17041-10000-00833	322 N HAWAIIAN AVE 1-6	90744	15	027B201   392	7417010908	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM				PC FOR FA SYSTEM FOR 6 UNIT APARTMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22774	14041-20000-32344	11777 W SAN VICENTE BLVD suite 601	90049	11	129B145    59	4401017026	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.05331	-118.46832	Plan check for energy only. TI to existing office on 6th floor of high-rise office building. New receptacles and lighting (incl. emergency). 1,524sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22775	12041-10000-25945	17350 W NORDHOFF ST	91325	12	198B129   466	2768022001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.23566	-118.51327	PV1 changed to standard plan for microinverters. system changed to 3.672 KWRoof mounted 4.16 KW PV for a single family, using microinverter enphase 215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22776	15041-10000-01504	2466 E 16TH ST	90021	14	118-5A217 294			Central				2060.31	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.01949	-118.2277	Plan check for Title 24. Project is lighting for a warehouse, as well as installation of new panels and a transformer (less than 400 amps of load is being added). Total lighting area = 27,310 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22777	18041-20000-08332	315 W 9TH ST Unit 101	90015	14	127-5A209 141	5144018049	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.04346	-118.25751	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a change of use from office to massage parlor/tenant improvement to the floor. Total lighting area = 4,711 sq. ft.Note: Building application has been generated under 17016-30000-17143	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22778	13041-20000-29505	333 S GRAND AVE 5th floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	plan check and permit for t24 part 6 energy lighting. 5th floor new lighting. 20000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22779	19041-10000-52438	7300 W MANCHESTER AVE	90045	11	096B157  1072	4119025025	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	04/13/2020 12:00:00 AM	ADDRESS	33.9596	-118.42266	T-24 PLAN CHECK FOR A TI TO 4 NEW BATHROOMS IN AN EXISTING PRE-SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22780	18041-20001-16988	21250 W CALIFA ST #115	91367	3	174B105    16	2149002018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.1769	-118.59414	02-05-2019 Changes to an approved set of plans, Changes include addtional wall lighting in the auditorium and main lobby, all changes has been clouded. and addtional 5 circuits for wall lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22781	15041-10013-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 42 ON PLANS. SCOPE INCLUDES ADDITIONAL CIRCUIT AND REVISION TO T-24.TOTAL ADDED AREA  600 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22782	13041-10002-29461	13111 W COMMUNITY ST	91352	6	192B161    41	2634029006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2014 12:00:00 AM			PC Approved	02/07/2014 12:00:00 AM	ADDRESS	34.22337	-118.41871	"Plan check only. "" $0 fee is due to the 2012 Senate Bill No. 1222"" Revision to approved plans. Relocate inverter and change wiring layout."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22783	15041-10000-00753	3236 E UNION PACIFIC AVE	90023	14	117A223    24	5169002009	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.01657	-118.20988	Remove HID light fixtures and install LED fixtures in (E) garment workshop.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22784	15041-10000-22031	110 E 9TH ST 9TH FLOOR-#979A	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.04107	-118.25479	PC FOR ENERGY. RENOVATION OF 9TH FLOOR OF A HIGH RISE BUILDING. ROSS STORE. TOTAL AREA 12780 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22785	14041-10002-28862	1635 N CAHUENGA BLVD	90028	13	148-5A187 221	5546007028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/05/2015 12:00:00 AM			PC Approved	01/05/2015 12:00:00 AM	ADDRESS	34.10071	-118.32971	Change to approved set  by removing (4) fixture AA  and installing (4) fixture A in office #1.(((PC FOR T24 ENERGY ONLY. TI FOR A OFFICE .TOTAL AREA 2152 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22786	11041-10001-06916	11321 W MISSOURI AVE	90025		126B149   509	4261021013	R3-1		West Los Angeles	West Los Angeles			Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM			PC Approved	03/23/2012 12:00:00 AM	ADDRESS	34.04226	-118.44566	New 9 units appartment Bldg. New 600 Amp service, panels, and circuits. EPC is for power & energy.(((((((3-23-12    Changes made to previously approved set per ispector mike dawson, conducror size changed from 250 MCM to # 1/0 and load ind panel HP changed from 159 amps to 137 amps and the bus duct converted to cable # 500 MCM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22787	17041-10000-22635	380-384 WORLD WAY MSC-EFSO	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	05/24/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	instalation of new EFSO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22788	16041-10000-01606	1734 S BAGLEY AVE	90035	5	129B169   904	4305025015	R1-1	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.04877	-118.39059	INSTALL 8.48 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: KYOCERA KU2656ZPA(1) INVERTER:  ABB PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22789	13041-10000-29874	3370 S LIVONIA AVE	90034	5	123B169  1520	4312013031	M1-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2701.00	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.02921	-118.39258	Title 24 for retail and office. permit under 13041-10001-29874.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22790	10041-20000-07194	1080 W WILSHIRE BLVD	90017	1	130-5A207 169	5143027016	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM			PC Info Complete	07/02/2010 12:00:00 AM	ADDRESS	34.05202	-118.2632	Plan check power and energy for A2 type restaurant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22791	14041-10000-05419	301 E FLORENCE AVE	90003	9	102B205   798	6011008030	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	33.97488	-118.269	TI for a new 7 Eleven retail store in an existing shell retail building.  New 600A rated service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22792	11041-20000-21807	333 S HOPE ST # 3750	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM			PC Approved	10/12/2011 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TI FOR OFFICE #3750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22793	10041-20000-04421	3829 S GRAND AVE	90037	9	117A203   170	5122026013	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM			PC Approved	03/15/2010 12:00:00 AM	ADDRESS	34.01448	-118.28006	energyixist. permit 10041-90000-03502	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22794	12041-10000-20040	6379 W HOLLYWOOD BLVD	90028	13	148-5A187 156	5546005011	C4-2D-SN	Central	Hollywood	Hollywood United		1902.00	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.10177	-118.32906	T.I. to an existing restaurant.  Load is less than 400Amps and occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22795	19041-20000-42430	13412 N MANZANILLO LANE	91342	7	225B157  1052	2510026017	(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.31535	-118.42221	Plan check for PV roof mounted system, PV System size: 1.68KW with 7 PV Modules and 7 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22796	17041-10000-09736	4851 S ALAMEDA ST	90058	9	111A215    13	5106027002	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Issued	04/21/2017 12:00:00 AM	ADDRESS	33.99921	-118.23904	PC FOR POWER ONLY REPLACEMENT OF MAIN SERVICE AND SWITCHGEAR. REFEED EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22797	16041-10001-27751	16904 W CITRONIA ST	91343	12	201B133   482	2686026001	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2016 12:00:00 AM			PC Approved	09/02/2016 12:00:00 AM	ADDRESS	34.24611	-118.50054	PV1 ROOF TOP MOUNTED SOLAR SYSTEM 11.4KVA SOLAR EDGE INVERTER(SE11400A-US240) WITH 38 MODULES\ AND SOLAR EDGE POWER OPTIMIZERS.EXPEDITE FEE PER APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22798	17041-10000-19202	801 S GRAND AVE 101, 102	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.04581	-118.25842	PC FOR POWER AND ENERGY FOR TI IN A BANK  TOTAL CONNNECTED LOAD > 400A BUILD OUT OF A COFFEE SHOP AND OFFICE IN A HIGH RISESCOPE INCLUDES NEW EQUIPMENT CIRCUITS AND LIGHTStotal affected area 5391sq.ftTENANT IMPROVEMENT  BUILD OUT OF A COFFEE SHOP AND OFFICE; 4802 SF CHANGE OF USE PORTION OF THE BUILDING FROM OFFICE TO COFFEE SHOP AND OFFICE. ADD 4 ATM MACHINES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22799	13041-10001-26745	5807 S AVALON BLVD	90011	9	108B205  1107	5101006005	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	33.98959	-118.26538	PLAN CHECK IS FOR EXTERIOR AND INTERIOR LIGHTING (MINIMUM) SYSTEMSINPREPARATION FOR LEASING NEW BUILDING((((((( 9500 sq ft shell building for future dialysis clinic with medical office.  Existing 800A service per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22800	17041-20002-40197	4617 N LARKWOOD AVE	91364	3	168B097   572	2074002017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Issued	01/05/2018 12:00:00 AM	ADDRESS	34.15516	-118.62822	Revisions to approved set of plans.  Change of design to (2) 6kW rated central inverters plus PV combiner panel.  $0 permit fee per State Senate Bill SB 1222.(((Plan check for solar pv system, roof-mounted array on SFD.11.4kW ungrounded system. (39) 325W pv modules.Each module has a 400W power optimizer.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22801	15041-20001-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.25734	-118.50614	12/07/2016 Changes to an approved set of plans. All changes have been clouded. Plan check to address clouded changes only. *****Previous Work Description*****CHANGE OF USE TO MEDICAL OFFICES. FULL TI. PC FOR POWER AND ENERGY. PER BUILDING PERMIT, PC IN ACCORDANCE TO 2008 NEC AND ENERGY CODE STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22802	16041-20000-02117	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.0965	-118.30717	TI for an existing building (offices). Plan check for power. Core and shell only.  New service 2,000A. Existing lighting to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22803	17041-10000-36230	954 N MEI LING WAY	90012	1	135A215   134	5414011025	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			Reviewed by Supervisor	10/16/2017 12:00:00 AM	ADDRESS	34.06549	-118.23752	PC for 5kW rooftop solar in commercial building. Installing new 5kW solar inverter with 20 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22804	18041-10000-03073	2737 S MANSFIELD AVE	90016	10	123B177  1606	5049015025	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.02978	-118.35338	Plan check for PV roof mounted system. Totla system size: 2.53kW with 11 modules and 11 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22805	11041-20000-03409	1880 CENTURY PARK EAST 5th fl	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	energy plan check # 5th fl cooridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22806	18041-20000-38771	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1211.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.23911	-118.3725	energy check for indoor lighting to a pre-fabricated office within a warehouse.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22807	12041-10000-29281	644 S MAIN ST	90014	9	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.04423	-118.25077	T.I.  Existing restaurant located on a single story building.  Upgrading service to 400 amps and modification to interior lighting. (Permit for 12 circuits and one 3 to 5 equipment issued under 12041-10000-06644)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22808	10041-20000-18148	17777 W VENTURA BLVD	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	05/10/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	energy plan check parking structure	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22809	19041-20000-06181	321 E ROSE AVE	90291	11	111B141   549	4286002014	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			02/20/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	33.997	-118.4764	PV2.  Install 13.44 kW roof mounted grid tied PV system.  (42) modules with (4) 3.8 kW rated string inverters and one string on microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22810	15041-10000-25048	2570 S LINCOLN BLVD Ste 101	90291	11	108B149  1026	4236031001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	33.99082	-118.44789	Remodel of existing T-Mobile retail location.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22811	16041-10000-29475	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Issued	12/27/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	An addition to existing fire alarm system for commercial bldg. The system uses existing fire alarm panels. Scope Includes an additional 2023 fire alarm devices for all floors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22812	18041-10000-28634	24050 S FRAMPTON AVE	90710	15	039B197    13	7439010018	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	33.8059	-118.29973	PLAN CHECK FOR FOR TITLE 24 FOR REMOVAL OF HID FIXTURE TO NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22813	12041-10000-18654	120 S LOS ANGELES ST	90012	14	130-5A213  98	5161016027	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM			PC Approved	08/08/2012 12:00:00 AM	ADDRESS	34.05092	-118.24262	"Change to lighting in a ""Place of Assembly"".  This application is for Plan Check Only for T-24,  NO Permit.   Submittal for FULL PLan Check will be on a separate application.  (Per B.H.)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22814	13041-10000-28697	400 S HOPE ST #2050	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.05199	-118.25366	REMODEL OFFICE SUITEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22815	18041-20000-38842	6080 W CENTER DR 12th Floor-Rest Rooms	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	33.97713	-118.39172	Plan check for Title 24 only in restroom 12th Floor Total area: 588 sq ft. B#18016-10000-27895	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22816	15041-20000-17245	14822 W LEADWELL ST	91405	6	186B149   664	2218020018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.20381	-118.45606	Plan check for a PV1 roof-mounted PV system. System was an existing 3 kWac and a 3 kWac addition will be made, for a total system size of 6 kWac. System addition consists of (1) inverter, (12) modules, and (1) load center. Standard plan is not being used.Note: Original 3 kWac system was permitted under 11041-20000-24568	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22817	18041-20000-42525	9868 N SUNLAND BLVD	91040	7	201B181   152	2545014006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.24889	-118.34724	Plan check for PV roof mounted system, system size: 9.9kW DC, 8.415kW AC with 33 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22818	19041-10000-25695	1875 S CENTURY PARK EAST 270 & 280	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.06115	-118.41457	T-24 PLAN CHECK FOR A TI TO AN EXISTING OCCUPANCY OFFICE. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 3437 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22819	18041-30000-43487	2029 S CENTURY PARK EAST 2ND FLOOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT RENOVATION OF PUBLIC RESTROOMS ON 2ND FL. NEW LIGHTS WILL CONNECT TO EXISTING BRANCH CIRCUIT SERVING THE AREA. TOTAL AREA: 410 SQ.FT(B# 18016-10000-25385)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22820	13041-10000-33119	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	TI of right field bullpen overlook for Dodger Stadium.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22821	17041-10000-27221	510 N BONHILL ROAD	90049	11	135B141   234	4403019004	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.06798	-118.4812	PC for new 11.04KW rooftop solar. Installing  32 AC modules, one combiner panel and one subpanel. Note that exisitng PV installed on rooftop for pool equipment, PC to verify exisiting PV interconnection to system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22822	14041-10000-17835	1220 W HARRY BRIDGES BLVD	90744	15	027B201   208	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	33.77024	-118.27673	Plan check for power only.  Remove and replace ATS, generator, VFDs, pumps, and motors in existing industrial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22823	10041-20000-17427	1901 S AVENUE OF THE STARS # 600	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	12/09/2010 12:00:00 AM	ADDRESS	34.05949	-118.41705	energy plan check # 600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22824	19041-20001-08248	6200 N DE SOTO AVE	91367	3	177B109   225	2149004020	(Q)C4-2D	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.18284	-118.58981	NEW ROOFTOP PV SYSTEMS FOR EXISTING APARTMENT BUILDING. 2 SEPERATE SYSTEMS.SYSTEM #1: 45.36 KW DC/ 40.73 KW AC CEC/ 40.2 KW ACSYSTEM #2: 101.16 KW DC/ 90.84 KW AC CEC/ 90.5 KW ACSCOPE OF WORK INCLUDES (407) ASTROHALO PV MODULES, (205) P730 OPTIMIZERS, (5) SE20KUS INVERTERS, (1) SE30KUS INVERTER, (1) 50KVA TRNASFORMERS, (1) 150KVA TRANSFORMERS, (1) 125A PANEL, AND (1) 200A PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22825	15041-20000-26326	2000 S AVENUE OF THE STARS MEZANIN-Suite 500	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for title  24 only T.I. for for office CAA Crative Artist Agency.  Total area: 5,034 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22826	16041-10000-18901	2152 E SANTA ANA BLVD NORT	90059	15	088-5A217 727	6067028035		South Los Angeles				2430.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	PIN	33.93569357	-118.23365444	PV1, INSTALL NEW 2.08 KW DC ROOF -MOOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(8) MODULES:  HYUNDAI HEAVY INDUSTIES 260W (1) INVERTER: ABB PVI-3.0-OUTD-S -US-A 240	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22827	11041-10000-03878	400 W WORLD WAY TERMINAL 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM			PC Approved	03/01/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	TITLE 24 ONLY, AIRPORT TERMINAL 4.  PROJECT REMOVED WALL AND ADDED OFFICE SPACE TO EXPAND TSA SCREENING AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22828	09041-20001-19116	1030 N ALVARADO ST 1-20	90026	13	139-5A207 119	5404003032	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM			PC Approved	04/08/2010 12:00:00 AM	ADDRESS	34.07715	-118.26352	REVISION TO PREVIOUDLY APPROVED PLAN COMBINING THREE STRINGS IN TO ONE INVERTER. FOR New Commercial PV System.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22829	17041-10002-44844	500 WORLD WAY DELTA 2017-OAL	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC FOR DELTA 24 CHANGES TO APPROVED SETSCOPE INCLUDES REMOVAL OF 2 BRANCH CIRCUITS AND LIGHTING REDUCTIONPLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22830	18041-10000-13837	11133 N BALBOA BLVD	91344	12	210B133   328	2697025004	(T)(Q)C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.27305	-118.50254	Permit fee is $0.00 due to AB1414INSTALL NEW SOLAR SYSTEM WHICH INCLUDE A 494.2 kW dc / 414 kW ac ROOFTOP SOLAR ARRAY WITH 1392 SOLAR MODULES & ASSOCIATED ELECTRICAL EQUIPMENT.(5) central inverters at 80kW (1392) modules(1) 600A load centerPV CONNECTS TO (E) 2500A, 480/277V, 3PH, 4W(B# 18016-10000-11613)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22831	13041-20000-02760	11611 W SAN VICENTE BLVD	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM	02/04/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.0541	-118.46261	Change to lighting to an existing bank.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy,  with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22832	17041-20001-14452	239 W 25TH ST	90007	9	121-5A205 138	5126020012	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.02729	-118.27101	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on commercial building. Interconnect with a 400A MSP.30kW ungrounded system. (108) 275W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22833	19041-10000-25108	123 E 35TH ST	90011	9	118-5A205 257	5120006016	M1-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Closed	02/05/2024 12:00:00 AM	ADDRESS	34.01764	-118.27242	Energy plan check for removing HID fixture and replace with new LED fixture for indoor lighting with a total area of 10358-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22834	14041-10000-03151	17015 W DEVONSHIRE ST	91325	12	204B133   170	2695020033	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.25768	-118.50301	New fire alarm system in a 3-story commercial building.  Silent Knight 5808 FACP coordinating 61 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22835	11041-10000-20997	505 S FLOWER ST STE B430	90071	14	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/03/2011 12:00:00 AM	ADDRESS	34.0515	-118.25654	TI TO AN EXISTING RESTAURANT.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22836	14041-20000-32969	7581 W VALAHO DR	91042	7	204A197   357	2558028025	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.25334	-118.29773	pv1install roof mounte pv system sized 4kw interconnected with msp.(16) solarworld sw280 modules(16) enphase m250 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22837	10041-20000-10185	10235 N GLENOAKS BLVD	91331	6	204B165   159	2537017031	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	07/07/2010 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.25613	-118.39454	new industrial center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22838	17041-20000-29361	6300 W WILSHIRE BLVD Suite 610	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 2,848 sq. ft.Note: Building application has been generated under 17016-10000-22876	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22839	18041-20000-12875	1990 S BUNDY DR Suite 450	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.03419	-118.45559	Plan check for Title 24 only in existing space T.I. office new lighting, existing circuits. Total area: 2772 sq ft.18016-10000-08849	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22840	18041-10000-44900	5301 N EXCHANGE ST	90039	13	165B201   142	5593007009	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.14882	-118.27588	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22841	13041-10002-30068	9338 W BEVERLYCREST DR	90210	4	147B165   400	4352011012	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.09738	-118.40185	Expedited RSES plan check per applicant request.(((PV1, Install 6.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE6000A-US. 27 modules Hanwha HSL60P6-PB-4-250TW.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22842	19041-10000-46442	1860 W OAK TREE DR	90041	14	162A223   112	5686011008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	34.13701	-118.20784	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 20.35KWdc (15.95KWac) USING 55 LG370Q1C-V5 MODULES AND ENPHASE IQ7PLUS-72-2-US  MICROINVERTERS. NEW ESS TESLA POWERWALL.$0 PERMIT FEE PER STATE ASSEMBLY BILL AB 1414 AND SB 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22843	16041-10000-11077	111 E UNIVERSAL HOLLYWOOD DR 27TH FLR	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON THE 27TH FLOOR. SCOPE INCLUDES RELOCATING/ADDING NEW LIGHTING FIXTURES FOR AN EXISTING OFFICE SPACE ON THE 27TH FLOOR. ALSO ADDING TWO 225A PANELS AND RECEPTACLES.  TOTAL AFFECTED AREA IS 3893 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22844	13041-20000-32969	10012 N WEALTHA AVE	91352	7	204B173   406	2538028013	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.25214	-118.37334	PV1 MICROINVERTER STNDARD PLAN. TOTAL SYSTEM SIZE 3.88KWAC. 18 MODULES AND MICRO INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22845	14041-10001-02789	14702 W PLUMMER ST	91402	6	198B149    61	2650031001	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.24255	-118.45386	Expedited RSES plan check per applicant request.{{PV1, Install 5.5 KW DC roof-mounted solar array on a two story home, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U. (22) Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22846	12041-10001-12382	221 S GRAND AVE	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.05419	-118.2505	(((CHANGES MADE TO APPROVED SET. CHANGING EST3 GENESIS TO WHEEL LOCK (SPEAKER STROBES.)))New fire alarm system for Broad Museum.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22847	13041-10000-33024	139 S LAYTON DR	90049	11	135B145   274	4365004020	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Expired	04/04/2016 12:00:00 AM	ADDRESS	34.06823	-118.46894	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 5 KW. TRANSFORMERED, NEGATIVELY GROUNDED SYSTEM.(20) YNGLI YL250(20) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22848	11041-10001-24398	6022 W AVION DR	90045	11	090B165    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	33.94182	-118.39269	New restaurant at LAX Terminal C, Space C1.  First time tenant, with new panel, circuits, and equipment.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22849	17041-10000-39853	1888 S CENTURY PARK EAST 3rd floor	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.06104	-118.41402	T-24, PC FOR LIGHTING ONLY. T.I. TO EXISTING OFFICE SPACE. TOTAL SQ. FT. 1152. B#17016-10000-27823	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22850	19041-10000-53561	2310 W OCEAN VIEW AVE 1-24	90057	1	135A203   351	5154037003	R4-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Apartment			12/27/2019 12:00:00 AM			PC Approved	11/14/2022 12:00:00 AM	ADDRESS	34.06268	-118.27585	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES 1 NEW SERVICE OF 1000 AMPS, 120/280, 3 PHASE 4 WIRE. (24 UNIT PANELS WITH 6 TYPICAL UNITS)TOTAL AFFECTED AREA: 17,278 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22851	14041-20000-20751	10877 W WILSHIRE BLVD Ste 1520	90024	5	132B153   297	4360003029	[Q]C4-3-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.05934	-118.44254	TI to commercial office space in (E) highrise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22852	11041-10000-26049	500 W WORLD WAY 5C	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Closed	04/18/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. to an existing restaurant at  LAX , Terminal 5, Space 5C.  Change to lighting and new receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22853	19041-10000-08070	6130 N LAUREL CANYON BLVD STE. 105	91606	2	177B165  1100	2334011029		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Issued	03/19/2020 12:00:00 AM	ADDRESS	34.18148	-118.39573	FULL PLAN CHECK FOR FIRST TIME TENANT IMPROVEMENT, RETAIL. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER, WITH EXISTING PANELS AND NEW CIRCUITS. TOTAL SQ. FT. 10030.(B# 19016-10000-06094)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22854	17041-10000-44619	705 S GAYLEY AVE 1-12	90024	5	135B149   456	4363007020	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.0654	-118.44812	PC FOR NEW FA IN NEW APRARTMENT BUILDING. TOTAL DEVICE COUNT 80 WITH FACP PANEL AND POWER EXTENDER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22855	18041-10000-37504	1271 W 39TH PL	90037	8	117B197   914	5037007019	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.01423	-118.29941	PC FOR NEW FA FOR A NEW 3-STORY 8-UNIT APARTMENT.SCOPE INCLUDES 2 PANELS AND 46 DEVICES.B# 13010-70000-04687	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22856	19041-30000-04549	7590 N GLENOAKS BLVD #200	91504	2	186B181    61	2401042012	(Q)C1.5-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	10/17/2020 12:00:00 AM	ADDRESS	34.20894	-118.34376	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 25,480 sq. ft.Note: Building permit has been issued under 18016-10000-32234	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22857	15041-10000-01161	7125 N RIVOL ROAD	91307	12	183B089   138	2028037016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.20023	-118.6545	Installation of new solar PV array.  3.6 kWac transformerless system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22858	12041-10000-09665	15037 W RAYNETA DR	91403	5	163-5A147  22	2277009020	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.14429	-118.46233	Plan check installation 5.28KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22859	18041-10000-39836	7459 N SHIRLEY AVE	91335	3	186B117   438	2116006072	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.20629	-118.55803	NEW 11.5KW ROOF MOUNTED PV SYSTEM WITH 32 AC MODULES ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22860	19041-10000-42731	8501 N OSO AVE	91306	3	192B113   203	2781012011	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.22484	-118.57554	PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SE3800H-US WITH EV CHARGER) WITH 16 MODULES USING P320 OPTIMIZERS CONNECTED TO EXISTING 100 SERVICESYSTEM SIZE IS 3.8KWac AND 4.960KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22861	18041-10000-37047	5000 S CENTRAL AVE	90011	9	111A209   302	5107027001	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	33.99791	-118.25629	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22862	16041-10001-24669	2368 W PICO BLVD	90006	1	129B197  1081	5056004007	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.04706	-118.28833	Supplemental PC for changes from mixed used building to commercial building. Changes include changing upper two floors from apartment to office units with no changes in subterranean basement ,1st flr medical office and outdoor lighting.  PC for new 600 A distribution board, 8 new panels and new equipment . Total affected is 11380 sqft. Building under 15010-20001-00412.  All chanages are clouded .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22863	10041-10000-03289	900 S WESTGATE AVE 101-106	90049	11	129B145   397	4265017041	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01, 2643.02	Electrical	Electrical	Apartment			03/02/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	03/03/2011 12:00:00 AM	ADDRESS	34.05068	-118.46804	19 UNITS  APARTMENT THREE STORY. SUB PARKING , POWER AND ENERGY .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22864	19041-20000-50896	7160 W SUNSET BLVD	90046	4	147B181   677	5548018027	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			12/10/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Issued	03/03/2020 12:00:00 AM	ADDRESS	34.09778	-118.34615	T24 PLAN CHECK, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 1583 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22865	14041-20001-09565	4515 N ENCINO AVE	91316	5	165B129   105	2290019006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.15154	-118.51415	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTLA SYSTEM SIZE 14.8KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING 3 CENTRAL INVERTERS. USING POWER OPTIMIZERS(($0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22866	13041-10000-22199	3650 W MARTIN LUTHER KING, JR BLVD #139	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	TITLE-24 FOR A 670 SF (E) FOOD COURT SPACE.TENANT IMPROVEMENT;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22867	12041-10000-00536	238 E 1ST ST	90012	14	130-5A213 137	5161016010	[Q]C2-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/09/2012 12:00:00 AM			PC Approved	01/10/2012 12:00:00 AM	ADDRESS	34.05053	-118.24144	T. I. for restaurant space in an exist. bldg., 1st flr. P/check for compliance with lighting reqmts. of T-24 including emergency egress and exit lights.Permit under #12041-10000-00183	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22868	10041-20000-11395	1800 N HIGHLAND AVE #101	90028	4	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	07/30/2010 12:00:00 AM	ADDRESS	34.10436	-118.33763	Plan check T-24 Energy (general/emergency) lighting for office TI Suite#101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22869	15041-10000-22484	1683 W BLAKE AVE	90031	13	147A213   215	5442009017	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM			Reviewed by Supervisor	07/20/2015 12:00:00 AM	ADDRESS	34.09562	-118.24178	Full plan check for a change of use from factory to a Gym (B occupancy) T.I. Scope includes (2) new panel connecitng through an existing 800-Amp service, (48) circuits, (4) equipment, and Total 40,562-SQ feet for T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22870	13041-20004-35598	11985 W BLUFF CREEK DR BLDG #3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	CHANGE TO FEEDERS FROM COPPER TO ALUMINUMALL CHANGES HAVE BEEN CLOUDED DELTA VE FOR VALUE ENGINEERING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22871	11041-10000-01830	2057 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	07/01/2011 12:00:00 AM	ADDRESS	34.03957	-118.44272	TENANT IMPROVEMENT IN AN EXISTING RESTAURANTPLAN REVIEW IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22872	14041-20000-23215	11744 N MARIPOSA BAY LANE	91326	12	213B113    27	2701031021	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	10/25/2014 12:00:00 AM	ADDRESS	34.28411	-118.56561	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.0KW INTERCONNECTED WITH MSP.(38) KYOCERA TSM-255 MODULES(2) SOLAR EDGE TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22873	11041-20000-21408	555 W 5TH ST 9th Floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I. on the 9th Floor of a high rise building.  Plan check is for energy and emergency only.Fire/Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22874	14041-20000-30719	1641 N WESTERLY TER	90026	13	144A205   196	5425016011	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.08947	-118.26961	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(12) CANADIAN SOLAR MODULES 235PX WITH POWER OPTIMIZERS (1) SOLAREDGE 3KW TRANSFORMERLESS INVERETR	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22875	19041-20000-49749	4019 N TUJUNGA AVE	91604	2	162B173   488	2368023023	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	07/20/2021 12:00:00 AM	ADDRESS	34.14041	-118.37908	Plan check for Title 24 Energy only. New lighting in the space. Total area: 2672 sq ft.B#19016-10000-34682	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22876	18041-10000-44896	1479 N VIA CRESTA	90272	11	132B125    23	4420040013	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM			PC Info Complete	02/21/2019 12:00:00 AM	ADDRESS	34.05639	-118.53621	"PLAN CHECK FOR POWER ONLY(NO PERMIT - PERMIT UNDER COMBO PERMIT - BUILDING) FOR NEW 3 STORY SFD. SCOPE INCLUDES NEW 1200A 120/208V SERVICE WITH 19 PANELS AND ASSOCIATED LOADS - 4 PANELS HAVE LOAD OF ""0"" TO BE UPDATED SEE PANEL SCHEDULES"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22877	14041-10000-07776	4707 S ARLINGTON AVE	90043	8	111B189   787	5015034005	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.00073	-118.31828	PV1, INSTALL 1.75 KW DC ROOF-MOUNTED STANDARD SOLAR ARAY ON A TWO STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PVI-3.0-OUTD-S-US-Z-A(7) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22878	19041-10000-09660	5534 N CAHUENGA BLVD	91601	2	174B177   761	2417001035	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.17103	-118.36139	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22879	19041-10000-08787	12575 W BEATRICE ST	90066	11	105B161   974	4211006009	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Issued	03/12/2019 12:00:00 AM	ADDRESS	33.98087	-118.41547	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3300 SQ. FT. B#17016-20000-14454	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22880	11041-20000-25159	17037 W ALBERS ST	91316	5	174B133   706	2258030003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2011 12:00:00 AM			Reviewed by Supervisor	12/07/2011 12:00:00 AM	ADDRESS	34.17044	-118.50466	Photo Voltaic system roof  mounted on single family dwelling, using Enphase M215 inverters.  A variance to use un approved equipment is to be filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22881	16041-10000-03797	11240 N GLENOAKS BLVD	91331	7	210B161   139	2533019032	[T][Q]C2-1VL-CDO, [T][Q]P-1VL-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.27478	-118.41258	T-24, TI TO AN (E) RESTAURANT, MCDONALDS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2925	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22882	11041-20000-08189	4312 N WOODMAN AVE #302	91423	4	165B157   591	2360006060	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	06/06/2011 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.14854	-118.43103	energy plan check unit # 302	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22883	10041-20005-25118	1200 S SANTA FE AVE	90021	14	123A217   315	5166007011	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.02944	-118.22979	Changes from previously plans.  All changes indicate by DELTA 4.  Changes include reconnected panel, elevator, and relocate receptacles.  Plan check for power only.*****((CHANGES TO APPROVED SET. CHANGES CLOUDED DELTA 1. 100A UNIT PANELS. CHANGES COVERED UNDER DELTA 3. COMPLY WITH DEPARTMENT ORDER effective date11/18/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22884	16041-20000-44549	1060 S BROADWAY	90015	14	126A209   131	5139014011	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.0397	-118.25861	Plan check for power and energy. Remodel (E) 10-story high rise building, convert from office to hotel. (2) New 1000A services. ~174 hotel units. T24: indoor area- 188,264sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22885	18041-20000-21277	10642 N BALBOA BLVD	91344	12	207B133   597	2684001024	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.26355	-118.50206	600A 3ph-4w 240/120V service upgrade for multi-tenant commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22886	14041-10003-05380	1999 W ADAMS BLVD	90018	8	123B193   477	5058015005	[T][Q]C2-2D	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM			PC Approved	04/08/2015 12:00:00 AM	ADDRESS	34.03285	-118.30872	(((4/8/2015)))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 ON THE PLANS.  CHANGES INCLUDE CORRECTION OF GENERAL NOTES.REVISIONS TO PERMITTED SET OF PLANS- SEE SINGLE LINE DIAGRAM; CHANGES TO LIGHTING SYSTEMPLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. ELECTRICAL UPGRADES TO THE GOLDEN STATE MUTUAL LIFE INSURANCE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22887	15041-20000-17990	13807 W RUNNYMEDE ST	91405	2	186B153   256	2215006001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.20585	-118.43385	Installation of new roof mounted solar PV array.  Total area = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22888	11041-20000-24047	21300 W VICTORY BLVD # 635	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.18813	-118.59618	PLAN CHECK T24 ENERGY COMPLIANCE T.I. IN SUITE #635. PERMIT FOR ELECTRICAL WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22889	14041-10000-12584	1141 1/4 E 12TH ST	90021	14	123A213   184	5132015040	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.03074	-118.24629	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 7598 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22890	13041-10000-36293	3521 S MOORE ST	90066	11	114B153  1113	4245007019	R1-1-HPOZ	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.00608	-118.44499	PV1, Install 9 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 5000A-US and Solaredge SE 3800-US. (36) Modules: Trina Solar TSM-250PA05.18.(36) Optimizers: Solaredge OP300-LV-MC4SM-2NA-Z   no fees , due to state sanate 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22891	19041-10000-47643	1057 S GAYLEY AVE	90024	5	132B149    81	4363025006	C4-2D-O	West Los Angeles	Westwood	North Westwood		2653.05	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	09/13/2023 12:00:00 AM	ADDRESS	34.06087	-118.44732	PLAN CHECK FOR POWER AND ENERGY FOR TI(MEDICAL FACILITY) - SYSTEM USING EXISTING DISTRIBUTION SYSTEM/PANELS WITH A TOTAL AFFECTED AREA = 4414 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22892	12041-10000-01364	2250 N TRACY TER	90027	4	148-5A205 160	5433017006	C1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2012 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Expired	09/08/2023 12:00:00 AM	ADDRESS	34.10195	-118.27352	New 5.04kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22893	19041-20000-30684	401 E SHERMAN CL	90291	11	105A145    38	4227012001	RW1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	11/22/2021 12:00:00 AM	ADDRESS	33.98348	-118.46546	POWER PLAN CHECK FOR INSTALLATION OF NEW 27 KWH ENERGY STORAGE SYSTEM AND (2) SUB PANELS FOR EXISTING SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22894	14041-10000-07458	3150 W WILSHIRE BLVD STE #116	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT, Fatburger. HIGHRISE.  COMMERCIAL   Bldg # 13016 10 26249) - INT T.I. OFRESTAURANT SHELL SPACE -  SF. PROPOSED UNROOFED OUTDOOR EATING AREA - 22 SEATS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22895	19041-20000-14372	719 N AMALFI DR	90272	11	126B129   443	4408013001	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM			PC Approved	01/24/2020 12:00:00 AM	ADDRESS	34.04176	-118.5118	PLAN CHECK FOR POWER SERVICE SIZE OF 1000A 120/208V 3P 4W, WITH 60KW STANDBY GENERATOR. Plan check onlyNote:Electrical Permit pulled under Building Combination permit. B#18010-20000-03645	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22896	18041-10000-43153	1219 N NORTH MAIN ST	90012	1	135A217   117	5409006048	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	03/03/2021 12:00:00 AM	ADDRESS	34.06442	-118.23235	NEW BREWING OPERATION. FULL PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT: 18016-10000-36500	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22897	10041-20000-01341	7850 N HASKELL AVE	91406	6	189B141   186	2206001017	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	03/15/2010 12:00:00 AM		Permit Finaled	08/18/2010 12:00:00 AM	ADDRESS	34.21333	-118.47474	T.I work in training facility. This  plan check is for lightng and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22898	15041-20000-12234	7331 W VALMONT ST	91042	7	204B197  1067	2558022009	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			PC Approved	04/29/2015 12:00:00 AM	ADDRESS	34.25242	-118.29217	PLANCHECK FOR T24 ENERGY. SINGLE STORY BOARDING HOUSE. TENANT IMPROVEMENT FOR COMMON AREAS.1854 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22899	16041-20000-13408	7175 W WILLOUGHBY AVE	90046	5	144B181   752	5531016007	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.0872	-118.34594	[[4/18/16 CHANGES TO APPROVED T24 PLANCHECK. PLANCHECK ONLY . CHANGES INCLUDE REPLACING EXISTING FIXTURES WITH  FIXTURE  D AND E.  ]Plan check Title 24 only for existing office space. Total indoor area: 7,014 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22900	19041-20000-37197	6100 W CENTER DR 7th floor	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	33.97733	-118.3922	Restroom remodel on 7th floor of (E) office building P.C for title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22901	13041-10000-17736	5019 N WILLOW CREST AVE	91601	2	171B177  1170	2419014016	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			Corrections Issued	07/05/2013 12:00:00 AM	ADDRESS	34.16181	-118.36282	INSTALL ROOF MOUNTED PV SYSTEM (5 KW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22902	16041-20002-20526	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.09782	-118.31646	(12/16/2016)CHANGES TO AN APPROVED SET OF PLANS TO REFLECT FIELD CONDITIONS NOTED DELTA 20.THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22903	15041-10000-18792	262 S NORMANDIE AVE	90004	10	135B197   127	5518007029	(Q)C2-1, C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.0695	-118.30016	Energy plan check for a restaurant expansion T.I; scope includes new equipment, lighting  and receptacles. Total area is 2130 SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22904	17041-10000-13123	850 S CRENSHAW BLVD	90005	4	132B189   661	5092002047	R3-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			04/21/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.05763	-118.32112	Installation of fire alarm system in new 5 story 44 unit apartment building.  Total system size = 179 devices + 1 FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22905	15041-10000-24332	1730 W CORDOVA ST	90007	1	126B197   893	5075037008	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.03889	-118.29553	REMOVE HIGH INTENSITY DISHCHARGE (HID) LIGHT FIXUTRES AND REPLACE WITH NEW LED LIGHT FIXTURES. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22906	17041-10000-26090	1755 W CHANDELEUR DR	90732	15	015B189    87	7559024002	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Closed	05/17/2018 12:00:00 AM	ADDRESS	33.73912	-118.31461	PLAN CHECK FOR BATTERY BACK UP SYSTEM - SYSTEM SYZE - 14KW - TESLA POWERWALL.PV SYSTEM UNDER PERMIT 17041-10000-26088PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE (5.0KVA) WITH BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF 1 INVERTER (SOLAREDGE 5000A) WITH 20 MODULES (SOLARCITY) AND POWER OPTIMIZERS(P400).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22907	17041-10000-32152	925 N MARTEL AVE	90046	5	144B181   707	5531025024	R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Issued	09/08/2017 12:00:00 AM	ADDRESS	34.08781	-118.35125	PLAN CHECK FOR REPLACEMENT OF EXISTING FIRE ALARM PANEL  AND ADDING 6 NEW FIRE ALARM DEVICES TO AN EXISTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22908	12041-10000-06644	644 S MAIN ST	90014	9	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.04423	-118.25077	Change to lighting, new receptacles, and loads.  Two existing 50A services, less than 400A of load.  Planc check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22909	19041-10000-45649	12812 N JOLETTE AVE	91344	12	222B129   194	2602012019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM			Reviewed by Supervisor	11/15/2019 12:00:00 AM	ADDRESS	34.303	-118.51258	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 21  (SOLARIA POWER XT-360R-PD) MODULES, 21 (ENPHASE IQ7PLUS-72-2-US) MICROINVERTERS, CONNECTED TO AN EXISITING 200A PANEL. SYSTEM SIZE IS 7.560KW DC AND 6.09KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22910	17041-20000-29156	13182 W CHESTERWOOD ST	91342	7	222B157   323	2512006027	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.30468	-118.42033	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 5 kWac and consists of (1) inverter, (18) modules, (1) 5 kWac Powerwall, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22911	12041-10001-04420	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019007	C2-1, CR-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.25776	-118.46707	Modification to previouslyl approved set of drawings for lighting change.          <<<<<<T.I. to an existing retail space.  New receptacles, loads and lighting.  PLAN CHECK ONLY for Energy, with Emergency lighting.  No suite number, per applicant.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22912	18041-20000-15833	8756 N VANALDEN AVE	91324	12	195B121   324	2784003026	M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Issued	09/18/2018 12:00:00 AM	ADDRESS	34.22981	-118.54906	800A 240/120V 3ph-4w service upgrade for (E) commercial manufacturing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22913	16041-20000-41778	5940 N MCDONIE AVE	91367	3	177B113   155	2151006009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.17894	-118.57278	Plan check for installation of solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP.7.6kW ungrounded system. (29) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22914	14041-10001-06164	2881 W 15TH ST	90006	10	129B193  1524	5074004021	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	03/15/2014 12:00:00 AM	ADDRESS	34.04549	-118.30557	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(13) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22915	12041-10000-05369	6801 W HOLLYWOOD BLVD #257	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Approved	03/08/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	TENANT IMPROVEMENTS TO EXISTING STARBUCKS.  Change to lighting and added receptacles.  NO Emergency lighting per applicant.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22916	17041-20000-31603	18200 W COLCHESTER WAY	91326	12	213B125   450	2870013019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.27894	-118.53147	PV1.  Install 7.6 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22917	15041-20000-40162	1100 S WESTWOOD BLVD	90024	5	132B153   178	4363022004	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.0605	-118.44507	Plan check for a fire alarm device. Project site is an existing commercial building. Fire alarm system consists of (1) FACP, (1) communication panel, and (16) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22918	13041-10001-20719	8631 W 3RD ST 120-121	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check only. Original Plans lost. Rechecking T24 only per supervisor. Permit fees to be pulled under original application. Non oshpd per applicant. Bldg#13016-10-15623:OFFICE TI FOR SUITES 120 & 121, INCLUDING: NON-BEARING PARTITIONS; NEW T-BAR; MILL WORK; FINISH WORK; & NEW PLUMBING FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22919	18041-10001-15851	933 E VERNON AVE	90011	9	112-5A209  33	5115013025	C2-1VL	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Apartment			10/08/2019 12:00:00 AM			PC Approved	10/08/2019 12:00:00 AM	ADDRESS	34.00407	-118.25923	RESUBMITALL FOR RESTAMP DUE TO LOST PLAN ORIGINAL SCOPE:FULL PC FOR POWER AND ENERGY FOR A NEW 4 STORY 21 UNIT APARTMENT BUILDING. SCOPE INCLUDES NEW SERVICE RATED AT 800A NEW PANELS (ONE TYPICAL PANEL FOR 21 UNITS), NEW LIGHTS, AND NEW CIRCUITS. TOTAL AFFECTED 5566 SQ. FT. B#16010-10000-02825 NOTE: 7 TYPICAL UNITS / 100% AFFORDABLE HOUSING (25% FASTER TO ASIGN)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22920	12041-20000-23710	8654 N SUNLAND BLVD	91352	6	195B177   477	2404026003	C2-1VL, R1-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Apartment			10/04/2012 12:00:00 AM	01/10/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.22745	-118.3659	PV Solar installation on an apartment. Enphase inverters in a 3-phase configuration. System size is 10.5kW DC. The  permit number for the building electrical is 12041-20000-03783.  Permit Fees are under INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22921	13041-10000-34279	21720 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Closed	08/31/2017 12:00:00 AM	ADDRESS	34.18733	-118.60234	PLAN REVIEW FOR THE 35KV SERVICE AND ASSOCIATED DISTRIBUTION SYSTEM TO SUPPLY A NUMBER OF BUILDINGS TO BE CONSTRUCTED AS PART OF A NEW MALL.PLAN CHK WILL BE FOR THE 35KV LANDINGS TO THE OUTSIDE PERIMETER OF EACH BUILDING FOOTPRINT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22922	13041-10001-07230	535 S CURSON AVE WEST Tower 49	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Apartment			12/31/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.06635	-118.35533	Manufacture simens has changed switch gear from a 4000 Amp to a tapered  bus 4000 sections, 3000 sections and 2500 sections.(12/31/2013){{Service upgrade to 4000A for a 13-story apartment building (Tower 49).  Install new switchboards, feeders, house panels, and replace unit panels.  All the existing branch-cirucit conductors to be remained and reconnected to the replacement unit panels.  No work done on branch circuit equipment and lighting.  Plan check for power only.}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22923	11041-20000-22450	14500 W ROSCOE BLVD	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.22136	-118.44937	This application is to separate the lighting and fire alarm application from the power.  The original application was submitted with all three in the same package but 2 different engineers signed the plans.  The same contractor will be pulling the permit for the lighting, power, and fire alarm applications.  This application will have fees based hourly.  All permit fees will still be under the original application #11041-20000-16429	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22924	15041-10000-32738	12307 W 6TH HELENA DR	90049	11	129B141    10	4405040007	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.05367	-118.47844	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1, INSTALL NEW 18.9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(63) MODULES:  SUNPERME SNPM-GXB-300()INVERTER:  SOLAREDGE SE7600A-US & SE11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22925	14041-10000-11092	938 E 60TH ST	90001	9	105B209    84	6007007006	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	33.98557	-118.25878	Remove HID light fixtures and replace with new fluorescent fixtures. TOTAL AREA 15048 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22926	19041-10000-46643	4658 N LONGRIDGE AVE	91423	4	168B157   544	2360025021	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.15559	-118.42124	(E-PLAN)NEW ENERGY STORAGE AND 2 PANELS (125 AMPS)  INSTALLATION WITH  AN EXISTING SERVICE OF 200 AMPS AND AN EXISTING SOLAR SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22927	19041-10000-45243	282 E 46TH ST	90011	9	112-5A205 255	5109010016	R2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2285.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	02/01/2021 12:00:00 AM	ADDRESS	34.00186	-118.26993	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 4.2KWdc (3.8KWac) USING 14 SILFAB SLA-M300 MODULES, 14 P320 OPTIMIZERS & SOLAREDGE SE3800H-US CENTRAL INVERTER. CONNECTED TO AN EXISTING 200 AMP SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22928	19041-10000-13824	6130 N LAUREL CANYON BLVD F100	91606		177B165   423	2334011026	(T)(Q)C2-1-SN						Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM			Corrections Issued	04/16/2019 12:00:00 AM	ADDRESS	34.18148	-118.39573	Full plan check for a first time tenant T.I.. Scope includes new lighting and equipment with a total area of 12,272-SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22929	19041-20002-17659	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.02198	-118.33376	11-27-2019 Changes to an approved set of plan, Changes include addtion of fire alarm devices, update to symbol legend, and update battery calculation. All changes has been clouded as delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22930	17041-10004-32559	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.06371	-118.2982	PLAN CHECK ONLY. DELTA 4 CHANGES TO APPROVED SET. CHNAGES INCLUDE:*LIGHTING CHANGES PER FIELD CONDITIONS AND T-24 UPDATE*MINIMUM EMERGENCY LIGHTING FUTURE TI AREAS PROVIDED PER INSPECTOR REQUEST. EM LIGHTING TO BE REVISED FOR FUTURE TI. *REMOVAL OF ALL LIGHTING SUBPANELS AND RELOCATING LOAD TO TENANT PANELS.*REMOVAL OF 100A HOUSE PANEL LOCATED IN THE BASEMENT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22931	12041-20000-31182	13455 W MAXELLA AVE electrical-room D & B	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	Install an 800 ampere meter main section in electrical room D to supply MSA which is to be installed by others.  The connection shall require connecting to an existing 800 ampere busway supplied from MS.  Also, install a 400 ampere meter main at existing meter board MB which will supply existing distribution board DB located in electrical room B.  The 400 ampere section shall be supplied from a tap at MB.  Also retrofit existing fused disconnects at MS all as shown on page E-3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22932	19041-20000-51353	22206 W WELBY WAY	91303	3	180B101   116	2139013008	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.19272	-118.61045	PV1.  Install 5.27 kW DC / 4.779 kW AC roof mounted PV system.  (17) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22933	10041-10000-07803	10610 W VENTURA BLVD	91604	4	162B177   404	2378001020	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	05/24/2010 12:00:00 AM	ADDRESS	34.13734	-118.36371	T.I. for existing Subway.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22934	16041-10000-23008	5422 W CARLIN ST	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.03039	-118.3617	PV1, INSTALL NEW 3.445 KW DC ROOF-MOUNTED FOR A ONE UNIT OF A 3-UNIT BUILDING.(13) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22935	11041-10000-10373	10747 W MAGNOLIA BLVD 1-126	91601	4	171B177   600	2416024900	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Public Safety Only			05/20/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.16505	-118.36517	New Fire Alarm System for an appartment Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22936	19041-10000-48840	10639 N GLENOAKS BLVD	91331	7	207B165   213	2536015221	[T][Q]MR1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.26264	-118.40007	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR/OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22937	18041-10000-43576	11150 W SANTA MONICA BLVD 5th Flr	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI OF RESTROOMS ON 5TH FLOOR. T-24 ENERGY ONLY.BUILDING PERMIT: 18016-10000-35477	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22938	13041-10000-33118	15040 W OXNARD ST	91411	4	177B145   482	2243021004	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.17912	-118.461	TITLE 24 PART 6 ENERGY; SCOPE OF WORK IS FOR REMOVING (E) HID FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. 41 TOTAL UNITS. PROJECTED AREA IS AROUND 9639 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22939	19041-20000-15603	2931 1/2 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.10442	-118.24378	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22940	14041-20001-03658	7008 N STANSBURY AVE	91405	6	183B153   579	2217015020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	34.19795	-118.44095	Fee for Expedite ONLY****Roof mounted PV system with 6.5KW****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22941	19041-10000-42418	4151 W 3RD ST UNIT B	90020	10	135B193   203	5517014018	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2114.20	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.06914	-118.30436	FULL PC CHANGE OF USE TO MEDICAL, ADDING AN MRI MACHINE PARTIAL  PERMITS ARE PAID UNDER 18041-10001-46365. SCOPE OF WORK INCLUDES NEW LGIHTING AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22942	18041-10000-22570	1900 S AVENUE OF THE STARS Suite #330	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI in an existing office area in Suite #330, on the 3rd Floor.T-24 Energy ONLY. 1336 Sqr Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22943	13041-10001-33027	12627 W MILBANK ST	91604	2	168B161  1034	2362017015	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.15327	-118.40838	Expedited RSES plan check per applicant request.[][]]PV1, Install 7.5 kW DC roof-mounted solar array, interconnect with service panel.(2) Transformerless inverter(s):Solaredge SE3000A-US and SolarEdge SE3800A-US. (30) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22944	19041-30000-14193	601 S FIGUEROA ST 26th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site are the common area restrooms on the 26th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 520 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22945	16041-20001-11729	648 N MARTEL AVE	90036	5	141B181   607	5526020027	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.08325	-118.35098	Plan check Title 24 only for existing space. Total area: 1,019 sq ft. {{{{{{Run new 8 lines to subpanelInstall 15 outletsInstall 2 recessed lightsInstall 2 bathroom fans}}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22946	11041-20000-22807	16030 W VENTURA BLVD #605	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	12/20/2011 12:00:00 AM	ADDRESS	34.15598	-118.48247	s.605 T.I.  Medical office.  Removing existing branch circuits and installing new ones.  Also modifying the existing light fixtures.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22947	19041-20000-08633	16423 W HAMLIN ST	91406	6	180B137   504	2231003025	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.18854	-118.49103	PV1.  Install 4.62 kW DC / 3.927 kW AC roof mounted grid tied PV system.  (14) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22948	17041-10000-00457	555 W 5TH ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR TITLE 24. ENERGY ONLY INSTALLING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1810 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22949	18041-20000-45123	6727 N BUFFALO AVE	91401	2	180B157   158	2329001052	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.19284	-118.43027	Plan check for a PV1 roof-mounted PV system. System size is 11.16 kWdc/9.95 kWac-CEC and consists of (31) modules, (31) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22950	17041-20000-08696	12444 W CHANDLER BLVD	91607	2	171B165   144	2347031029	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			03/17/2017 12:00:00 AM	10/08/2020 12:00:00 AM		Permit Finaled	07/13/2023 12:00:00 AM	ADDRESS	34.16819	-118.40448	2500A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22951	19041-20000-34209	18742 W EDLEEN DR	91356	3	168B121   304	2176023025	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	34.15645	-118.54014	Plan check for PV roof mounted system, PV system: 11.16KW DC, 9.98KW AC CEC with 36 PV Modules and 36 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22952	19041-20000-00479	1225 N EL CENTRO AVE	90038	13	144B189   270	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Issued	01/28/2019 12:00:00 AM	ADDRESS	34.09329	-118.32459	Plan check for a PV2 roof-mounted PV system. System size is 107.1 kWdc/79.8 kWac and consists of (7) inverters, (306) modules, and (1) load center.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22953	14041-20000-21105	10219 N MELVIN AVE	91324	12	204B117   263	2726009052	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.25604	-118.5608	PV1.  Install 6.24 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22954	18041-10000-45501	12147 W MAGNOLIA BLVD	91607	2	171B165   487	2347019010	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			11/30/2018 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.16501	-118.39813	NEW 4 STORY MIXED USE 36 UNITS APARTMENT BUILDING PLUS RETAIL AND  FIRST FLOOR GARAGE. TOTAL AFFECTED AREA IS 14881 SQ. FT. BUILDING PERMIT: 17010-20000-04803	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22955	19041-10000-09803	19350 W NORDHOFF WAY STE F	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.23523	-118.55518	FULL PC FOR POWER AND ENERGY. TENANT IMPROVEMENT TO CONVERT THE SPACE INTO AN ALDI MARKET. SCOPE INCLUDES A NEW 600A DISTRIBUTION BOARD. TOTAL AFFECTED AREA IS 13,594 SQ. FT. B#19014-10000-01376	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22956	18041-10000-11803	18133 W VENTURA BLVD 2ND FLR	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Closed	02/23/2024 12:00:00 AM	ADDRESS	34.16603	-118.52861	FULL PC FOR A PARTIAL FLOOR TI FOR MEDICAL OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES FOR OFFICES AND BLOOD DRAW ROOM. TOTAL SQ. FT. 1715.Blgd Permit #13020-10K-00933	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22957	19041-20000-24699	1537 N NORFOLK ST 5th flr	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	11/10/2020 12:00:00 AM		Permit Finaled	02/05/2021 12:00:00 AM	ADDRESS	34.06138	-118.20223	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22958	17041-10000-31072	18117 W HERBOLD ST	91325	12	201B125   364	2764017038	RE9-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM			Corrections Issued	08/30/2017 12:00:00 AM	ADDRESS	34.24515	-118.52812	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES SINGLE INVERTER, 30 MOUDULES AND OPTIMIZERS. SYSTEM RATED 7.6KW AC/ 9.0KW DC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22959	18041-10002-32582	5858 W ABERNATHY DR	90045	11	099B169   101	4105006013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM			PC Approved	01/07/2019 12:00:00 AM	ADDRESS	33.97081	-118.38396	PC FOR CHANGES TO AN APPROVED PV SYSTEM. DELTA 1 CHANGES ONLY WHICH INCLUDES UPGRADING MODULES FROM SC325 TO SC330, CHNAGING NUMBER OF MODULES PER STRING AND THE AC DISCONNECT TO 90A.  NEW SYSTEM DC SIZE IS 11.88KWdc AND 10KWacORIGINAL PC****PV1. 11.7KW ROOFMOUNTED SOLAR SYSTEM + ENERGY STORAGE DEVICES 40.5KWH WITH  (36) MODULES INTERCONNECTING THROUGH A LOAD CENTER.****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22960	14041-20000-09440	15800 W ROSCOE BLVD	91406	6	192B141   492	2673021041	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.2212	-118.47638	PLANCHECK FOR INSTALLATION OF 5 PUMPS( 3- 2HP AND 2-3HP) IN A HAZARADOUS LOCATION. CLASS 1 DIV 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22961	16041-20000-34949	1999 S AVENUE OF THE STARS 33rd Floor-Corridor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for energy only. TI to corridor on 33rd floor. New lighting (incl. emergency). 1,468sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22962	14041-20000-19766	4904 N TOPANGA CANYON BLVD	91364	3	168B101   469	2171016044	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Issued	09/02/2014 12:00:00 AM	PIN	34.15717687	-118.60530012	Plan check for title Title 24 on a T. I. REMODEL TO (E) RESTAURANT ADDING (1) RESTROOM; REPLACE ALL COOKING EQUIP. & SINK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22963	19041-20000-28782	555 S FLOWER ST 3rd, 4th-flr	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	ti to an existing commerciasl building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22964	12041-10000-14959	10850 W NATIONAL BLVD	90034	5	123B157  1152	4254008003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	PIN	34.02994066	-118.42137081	New outdoor parking lot lighting from a 100A panel.  Plan check only for Energy.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22965	19041-10000-29133	138 N BEAUDRY AVE	90012	1	133-5A211 258	5160030015	CW	Central	Westlake	Echo Park		2080.00	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.06001	-118.2534	PC ENERGY ONLY FOR EXTERIOR AND INTERIOR REMODEL OF FLOORS 1-3 AND ROOFTOP. AREA OF SCOPE 4229.6SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22966	15041-10001-02728	6325 W RODGERTON DR	90068	4	157-5A189 162	5582010019	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM			PC Approved	07/13/2015 12:00:00 AM	ADDRESS	34.12578	-118.32282	Change of location for inverter from dwelling unit wall to adjacent to ground mounted array.  (((PV1, 8250 W DC GROUND -MOUNTED SOLAR ARRAY IN A ONE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL. 3 STRINGS. ONE INVERTER: SMA AMERICA SMA-SB7000-US(33)MODULES: PHONO SOLAR PS250P)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22967	17041-10000-02269	937 E 10TH ST	90021	14	124-5A211 322	5132004003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.03331	-118.24762	PC for outdoor Tile 24 only. Remove HID fixtures and replace with new LED fixtures. Area: 14,900..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22968	10041-10000-18861	7545 N FALLBROOK AVE	91304	3	186B097   261	2021012016	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	PIN	34.2079511	-118.62379412	"TI IN AN EXISTING ""TACO BELL"". PLAN CHECK IS FOR POWER & ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22969	18041-10000-32459	5440 S MCCONNELL AVE	90066	11	102B157    41	4211009019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	33.97786	-118.41934	PC FOR OFFICE TI FOR T-24  ENERGY ONLY!THIS IS DESIGN BUILT PROJECT. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS. TOTAL AFFECTED AEAR  4680 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22970	16041-10000-42320	7311 N LINDLEY AVE	91335	3	186B125   794	2119030021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.20373	-118.52753	PC FOR ENERGY. REPLACE OUTDOOR FIXTURES WITH NEW LED FIXTURES INCLUDING T24 EXEMPT LIGHTING IN PLAYGROUND. TOTAL AREA 59425 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
22971	17041-10000-03389	7650 W MELROSE AVE	90046	5	141B177   642	5527023029	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	05/30/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.08355	-118.35654	Plan check for Title 24 only in existing retail sapce T.I. new fitting rooms. Install new lighting in the fitting room. Total area: 302 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22972	13041-20002-35675	5835 N DONNA AVE	91356	3	174B121   777	2156012036	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.17647	-118.54771	(($0 plan check fee due to senate bill 1222 from 2012)))changes to approved set of plans. changes clouded F. change in location of equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22973	16041-20000-44966	418 N NORTH FARING ROAD	90077	5	141B157    12	4358007015	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			Reviewed by Supervisor	01/25/2017 12:00:00 AM	ADDRESS	34.08616	-118.43257	Plan check for power. (N) Two story accessory living quarter with covered patio at southeast side of the property (Accessory Building#2).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22974	11041-10000-22502	15300 W SUNSET BLVD	90272	11	129B125   555	4412002012	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM			PC Approved	10/20/2011 12:00:00 AM	ADDRESS	34.04733	-118.52598	T.I. to an existing restaurant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22975	17041-10000-11029	3610 S SOMERSET DR	90016	10	120B185  1202	5046002025	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.02364	-118.33724	PV INSTALLATION OF A NEW 2.320 KW DC/2.054 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A  DWELLING FAMILY HOUSE.(8) MODULES: SOLARWORLD 290 SW290 MONO(8) MICRO INVERTERS: ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22976	18041-10000-18420	2000 S LINCOLN BLVD	90291	11	108B149   104	4242003011	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	33.99575	-118.45581	Energy plan check for a retail store; scope include new lightings and receptale with a 400Amp service upgrade. Total area: 1530 sq.ftNote. portion of the fee is paid under permit number 17041-10000-33153	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22977	16041-20001-00337	1000 W WILSHIRE BLVD suite 400	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.05085	-118.26078	02-19-2016 Change to approved set of plans. Changes include additional lighting fixtures in lobby elevator area.{{{{{{{TI to existing high rise office building (4th floor). Adding new lighting including emergency. Total sqft. 12,212.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22978	10041-20001-19618	15524 W LANARK ST	91406	6	189B145    64	2654040004	M2-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.21839	-118.47093	Supplemental to previous submitted plans under Title 24 EPC only.  T.I. from industrial space to place of assembly (Banquet Hall).  A full EPC is required.  Install new panels and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22979	16041-10000-45036	4551 S GLENCOE AVE #330	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	33.9844	-118.43407	TENANT IMPROVMENT TO AN  (E) OFFICE SPACE. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22980	14041-20000-17533	11593 W KLING ST	91602	2	168B169   663	2354016040	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.1559	-118.38525	PV1.  Install 8.32 kW roof-mounted, utility-interactive PV system.  Transformerless inverter standard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22981	14041-20000-17199	5732 S CELEDON CK	90094	11	102B157   313	4211024***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	33.97471	-118.42179	New roof mounted PV system, total system size 5.36KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22982	15041-20000-31728	6301 N OWENSMOUTH AVE 8th Floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.18467	-118.60176	Plan check Title 24 only for Farmers Insurance in existing high-rise space. Total area: 19,559 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22983	19041-20000-32123	1892 N RISING GLEN ROAD	90069	4	150B169  1284	5561023045	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Issued	11/04/2019 12:00:00 AM	ADDRESS	34.10473	-118.3846	Plan check for power only for service upgrade 600A in existing Single family dwelling. Branch circuit existing to remain and pull permit under separate application. Existing panels to be replaced like for like.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22984	18041-10000-40028	1803 N CAHUENGA BLVD	90028	13	150A187   328	5546001400	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.10418	-118.33009	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY, Total sq. ft. 3600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22985	17041-10000-04356	7270 W WARING AVE	90046	5	141B181   293	5525012026	R1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.0852	-118.34819	Installation of a new PV1 roof mounted system in a single family home. Central inverter rated at 3.0 KW and a string of 12 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
22986	14041-10002-23471	21860 W BURBANK BLVD BLDG B	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			Reviewed by Supervisor	09/11/2014 12:00:00 AM	ADDRESS	34.17198	-118.60379	EXPEDITED PER APPLICANTS REQUEST.PHASE 2: : PV2 ROOF MOUNTED SOLAR SYSTEM. NEGATIVELES GROUNDED. NO NEW INVERTERS. TIED BACK INTO THE OLD SYSTEM.(60) YINGLI YL MODULESPHASE 1: 13041-10000- 29243 photo voltaic roof top for a 3 story bldg,768 modules, 3 combiner boxes, 2 inverters, Roof mounted , flat roof. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
22987	19041-20000-21984	10461 N WYSTONE AVE PV1	91326	12	207B121   773	2728015021	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.26071	-118.54826	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 16.56KW DC/15.2KW AC. SCOPE OF WORK INCLUDES A 100A LOAD CENTER, (46) LG ELECTRONIC PV MODULES WITH P370 OPTIMIZERS, A SE11400H-US AND SE3800H-US INVERTER$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22988	12041-10000-24161	11523 W SANTA MONICA BLVD	90025	11	126B149    25	4261002018	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	ADDRESS	34.04543	-118.45281	CONVERT A SINGLE SCREEN MOVIE THEATRE TO 3-SCREENS MOVIE THEATRETHE SINGLE THEATRE IS SUBDIVED INTO 3 EA THEATRES;ADDED PANELBOARDS AND NEW CKTS-LESS THAN 200A- TO SUPPLY NEW THEATRES. PLAN CHK IS FOR TITLE 24OCCUPANCY IS REDUCED AS TOTOAL NEW AREA FOR THE THREE THEATRES IS LESS THAN THAT OF THE ORIGINAL THEATRE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22989	13041-10000-32954	12951 W HARDING ST	91342	7	222B161   136	2512029081	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.30761	-118.41514	PV1, Install  5 kw DC roof-mounted solar array,   interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 20 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22990	13041-20001-29918	17200 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Issued	03/07/2014 12:00:00 AM	ADDRESS	34.20827	-118.50773	((((CHANGES MADE TO APPROVED SET OF PLANS. DID SOME CHANGES TO LIGHTING AND RELOCATED SOME RECEPTACLES)))). PERMIT IS FOR PHASE 1&2 CHANGESPLAN CHECK FOR POWER AND ENERGY. PHASE 1 :TENANT IMPROVEMENTS AND EXPANSION OF CHASE BANK. 3 TOTAL PHASES.  PHASE 1: ADDING PANEL 1 AND 2. SERVER ROOM AND ATMS.permit to be issued for reinspection of items	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22991	13041-10000-02202	1204 S HOOPER AVE	90021	14	121-5A213  94	5130024019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.02749	-118.24225	reconstruction of a fire damaged building. new lighting system. pc for T24 ONLY. total area of 2835 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22992	15041-10000-42443	1928 S COTNER AVE	90025	5	126B153   403	4323025021	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.04291	-118.44228	CHANGE OF USE FROM OFFICE / MANUFACTURING TO OFFICE / WAREHOUSE. TENANT IMPROVEMENT OF EXISTING 1ST STORY STORAGE SPACE IPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22993	14041-10000-17530	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	TITLE 24 PLAN CHECK.; RELOCATING ATM  ACROSS THE ROOM; PRIOR ATM SPACE WILL REMAIN AS AN OPEN SPACE ;RELOCATION OF ELECTRIC LIGHTING CONTROL, FIXTURES, RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22994	18041-10000-22048	1538 W SUNSET BLVD	90026	1	139-5A209 237	5404020003	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.07619	-118.25656	PC for energy only to a TI to an existing restaurant. Scope of work includes new panels, ligting and receptacles. Total connected load is <400ATotal sq. ft. 5163.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22995	13041-20000-30281	314 N BARRINGTON AVE PV-1	90049	11	135B141   121	4429023025	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.06895	-118.47258	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 16 KW AC USING 49 MODULES, TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. NEW SUBMITTAL FOR COMPLETE CHANGE IN SYSTEM.  Note: Permit fee is &0.00 due to Senate Bill from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
22996	19041-20000-53207	3653 S VAN NESS AVE	90018	6	180B149  1035	2241004007	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		2220.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Issued	12/24/2019 12:00:00 AM	ADDRESS	34.02165	-118.31677	Plan check for new Fire alarm system, Fire alarm devices: 23 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22997	16041-10000-12829	1600 N CAMPUS ROAD BERKUSHALL	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Issued	07/15/2016 12:00:00 AM	ADDRESS	34.12626	-118.21412	PC FOR T24 ENERGY ONLY. TI TO OFFICE SPACE. BERKUS HALL LOBB, OFFICE RENOVATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22998	16041-10000-41197	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.01118	-118.33649	PC FOR ENERGY. T.I  NO CHANGE OF USE, FAST FOOD KIOSK. CONNECTED LOAD <400 A, TOTAL AREA 340 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
22999	17041-10000-23915	13147 W TONOPAH ST	91331	6	195B161   663	2627022004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.22766	-118.41908	Install new rooftop solar system 6kW AC.  (24) modules with power optimizer and (1) inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23000	17041-20000-42858	1459 S LORENA ST	90023	14	118-5A223 178	5190030006	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.0174	-118.20886	service upgrade to an existing commercial building 800 amps. plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23001	16041-20001-40280	11944 W MONTANA AVE	90049	11	129B145   296	4265019033	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.05138	-118.47125	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 100A House Service. 19.7kW (6kW*2+7.7kW) ungrounded system. (75) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23002	18041-10000-46847	10250 N ETIWANDA AVE EV-1	91325	12	204B125   191	2731020919	[Q]PF-1XL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.25643	-118.53183	INSTALL NEW EV METER SWITCHGEAR, MTS, DISTRIBUTION, SUB PANEL AND ASSOCIATED INFRASTRUCTURE. INCLUDES THE INSTALLATION OF (1) NEW 50KW L3 DCFC AND (3) 6.6 KW L2 EVSE. THE SERVICE EQUIPMENT IS SIZED FOR FUTURE GROWTH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23003	12041-10000-15434	3833 S CRENSHAW BLVD	90008	8	117B185   783	5045019900	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.0162	-118.33546	New fire alarm system for exist. training center bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23004	12041-20000-04756	4424 N BERGAMO DR	91436	5	165B137    59	2284016027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.15206	-118.48686	New single family house with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23005	17041-20003-20920	4201 W WILSHIRE BLVD	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.06189	-118.31911	[[[ 3/22/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES ONLY. PLANS UPDATED PER INSPECTIONS INSTRUCTIONS]]]]03/15/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. PV system size has remained the same. PV system interconnection is now being done as a load-side connection onto a new 800-amp subpanel with a 600-amp MCB. New subpanel is being fed from the secondary of a 4,160V/480V transformer.*****Previous Work Description*****PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 131 KW.  INSTALLATION OF MEDIUM VOLTAGE TRANSFORMER .building permit # 17016-30000-16741	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23006	13041-10000-25586	1627 S LA CIENEGA BLVD	90035	5	129B173  1023	4303028024	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.0482	-118.3764	TITLE 24 PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALL NEW FLUORESCENT FIXTURES. 2050 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23007	14041-20000-27074	2118 E 7TH PL	90021	14	124-5A217 344	5166003012	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.0334	-118.22922	Change of use from warehouse to retail and office for core/shell building.  Install new 800A service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23008	12041-10000-13322	1615 N VINE ST	90028	13	148-5A187 258	5546009400	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00, 1910.00	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.10036	-118.32687	Plan check for new fire alarm. New panel and 63 devices. Existing 2 story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23009	14041-20001-04386	20513 W QUEDO DR	91364	3	169-5A111  64	2166023008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.15891	-118.5797	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23010	18041-10000-15680	3440 N OAK GLEN DR	90068	4	159B177   383	2425024012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.13167	-118.35439	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON SFD. SCOPE INCLUDES  22AC MODULES (SPR-X22-360-AC)SYSTEM SIZE 7.04KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23011	14041-10000-06356	1001 N SCHLEY AVE	90744	15	033B217   280	7428022903	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Expired	04/01/2016 12:00:00 AM	ADDRESS	33.78429	-118.2329	T24, REMOVING EXSITING LIGHT FIXTURES WITH NEW FLORESCENT FIXTURS. TOTAL AREA 5520 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23012	15041-10002-24535	18761 W CLEARBROOK ST PV1	91326	12	213B121   722	2871016035	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM			PC Approved	06/07/2016 12:00:00 AM	ADDRESS	34.27745	-118.54275	6/7/16: Revision to approved set, revise rooftop layout of modules.  All other remain the same. This is PC only.02/08/16PV1, ROOF MOUNTED SYSTEM USING CENTRAL INVERTER. (27) MODULES AND (1) 6KW, INVERTER. INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT #15041-10000-24535. (((INSTALL PV SYSTEM (27 PANELS, 1 INVERTER 7.02 KW) Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23013	17041-10000-39639	3650 W MARTIN LUTHER KING, JR BLVD SUITE#109	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.01118	-118.33649	PC for T24 only for addition of track lights in retail space with replacement fo fixtures to LED lights. B# 17016-10000-30687.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23014	13041-10000-31469	1236 W LEIGHTON AVE	90037	8	117B197  1164	5037003003	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.01307	-118.29858	PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US.  16 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23015	16041-10001-16555	105 S FAIRFAX AVE	90036	5	138B177   597	5511025032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM			PC Approved	09/28/2017 12:00:00 AM	ADDRESS	34.07398	-118.36162	CHANGES TO APROVED SET OF PLANS. CHANGES NO FLOOR PLAN LAYOUT AND DEVICE COUNTS/LOCATIONS. PC ONLY/ PERMIT COVERED UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23016	19041-10000-44489	2208 S WESTERN AVE	90018	8	123B193   167	5058016023	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.03604	-118.3088	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23017	17041-10000-25693	16058 W ANOKA DR	90272	11	132B125   110	4420006005	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.0535	-118.53399	$0 permit fee due to senate bill 1222 from 2012PC FOR ROOF MOUNTED PV SYSTEM ON SFD. SYSTEM SIZE IS 18KW ACSCOPE INCLUDES 62 MODULES WITH OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23018	15041-20000-27500	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Expired	09/27/2017 12:00:00 AM	ADDRESS	34.28583	-118.51165	Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (3) inverters, (57) modules, and (1) load centers.Note: permit fee is $0 due to SB1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23019	14041-20001-15508	14652 W OTSEGO ST	91403	4	171A149   187	2263033044	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM			PC Approved	08/08/2014 12:00:00 AM	ADDRESS	34.16291	-118.45266	change to approved set of plans. change in conduit cize to 3/4 in. plan check ok.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23020	19041-10000-43238	444 W UNIVERSAL HOLLYWOOD DR	91608	4	162B177   616	2424044037	[Q]C2-1-SN	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00, 3200.00	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			Reviewed by Supervisor	12/02/2019 12:00:00 AM	PIN	34.1391226	-118.35899994	PC FOR POWER ONLY, SCOPE OF WORK IS PROVIDING A NEW MEDIUM VOLTAGE 1200A, 4160V SERVICE TO A NEW BUILDING, BUILDING IS ALREAD IN PLAN CHECK UNDER APPLICATION NUMBER 19041-10000-20740. NOTE: COMPLETE BUILDING SINGLE LINE HAS BEEN PROVIDED AS REFERENCE ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23021	19041-10000-06196	570 W 5TH ST	90731	15	015B197   129	7451027001	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.73981	-118.28946	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23022	15041-10000-31384	1630 W 62ND ST	90047	8	105B193   808	6002028023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	33.98314	-118.30563	PV1, INSTALL NEW 6.625 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(25) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-6000-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23023	18041-20000-23482	6935 N MURIETTA AVE	91405	2	183B153   764	2216013005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.19671	-118.43901	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.05 KW DC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23024	18041-10000-22737	70 S FREMONT PL	90005	10	132B185   361	5090020014	RE20-1	Central	Wilshire	Greater Wilshire		2127.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/29/2018 12:00:00 AM	ADDRESS	34.05874	-118.32708	Plan check for a 7.6 KW AC PV1 roof mounted system with (27) modules, (1) 7.6KW inverter and (1) storage battery system interconnecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23025	11041-10000-25547	7755 N ORION AVE	91406	6	189B145   561	2222004003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	34.21181	-118.4707	New rooftop photovoltaic system for a single family residence and new 200A house panel upgrade.  System uses Enphase M215 microinverters.  Variance will be file to allow use enphase.  10  pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23026	16041-10000-43642	1828 E CESAR E CHAVEZ AVE #450	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.05014	-118.21571	"TI FOR MEDICAL CLINIC ""ACTIVE LIFE, INC."". NEW EXAM ROOMS AND RECEPTION AREA. PC FOR POWER AND ENERGY PER ART. 517.CILINIC PROVIDES ORTHOTICS, PROSTHETICS, AND COMPRESSION CARE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23027	18041-10000-03901	1117-1119 S SAN PEDRO ST	90015	14	124-5A211 207	5145025008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.03486	-118.25269	PC for power and energy for a TI in a commercial 2 story, change of use warehouse to office. scope includes new servive rated 800A 120/208, lighting, circuits, equipment. total Affected area is 21,334Sq.Ft B#17016-30000-28080	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23028	18041-20000-04743	308 S GLENROY AVE	90049	5	135B145    43	4366020007	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.07017	-118.46029	Plan check for power only. Project scope is the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23029	18041-10000-00772	7999 WORLD WAY WEST	90045	11	090B157    17	4129026910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.94186	-118.43203	PC for power only for new proposed loads. Providing feeder conduit and conductor to disconnects for future loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23030	16041-10000-17962	22840 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.18624	-118.62454	PC FOR FIRE ALARM SYSTEM TO MONITOR THE SPRINKLER SYSTEM WITH STROBES AND NEW FA PANEL. 42 FA DEVICES, 2 COMMUNICATORS AND 2 CONTROL PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23031	10041-20000-21496	25975 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM			PC Info Complete	10/28/2010 12:00:00 AM	ADDRESS	33.78721	-118.29774	Plan check by customer request for Kaiser LAN upgrade project consisting of new UPS, panel, and ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23032	13041-10000-28230	13517 W GILMORE ST	91401	2	180B157   806	2329006023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.18774	-118.42749	PV1, SOLAR INSTALATION, ROOFMOUNTED.SYSTEM SIZE 4.5 KW AC USING MICROINVERTER ON STANDARD PLAN WITH 21 MOUDULE. MODULE USING IS CANADIAN SOLAR CS6P-250P. M215 ENPHASE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23033	13041-10001-35923	12746 W JEFFERSON BLVD STE #3160	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Changes to an approved set of plans. Changes include the installation of a new 600-amp distribution board, (4) HVAC units, and (1) 300-kVA transformer. Changes have been clouded and marked as Delta 3.*****Previous Work Description*****NEW CVS PHARMACY. FIRST TIME TENANT TO NEW SHELL BUILDING. NEW 800A. AREA OF WORK IS APPROX. 17,468 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23034	14041-10000-15413	217 E 8TH ST	90014	14	127-5A211 327	5145003005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.04155	-118.25168	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 360 DEVICES AND 1 FACP WITH 4 POWER SUPPLIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23035	16041-10001-03642	3101 W FERNWOOD AVE	90039	4	147A205    73	5432026022	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.09867	-118.2706	03/01/16PC only for changes to an online permit. Changes include removing one 260 watt HYUNDAI module from single line/PV roof layout to reflect field.   Note: online permit paid under PCIS#16041-90000-03642((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23036	13041-10000-22429	2411 W OLYMPIC BLVD 1-6	90006	1	130-5A201 110	5136003016	C2-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.05258	-118.28373	PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR INDOOR AND OUTDOOR LIGHTING, AND EMERGENCY LIGHTING. NEW WALK UP ATM AT EXISTING BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23037	17041-20000-23103	5757 W WILSHIRE BLVD 2nd Floor	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	TI/Replacement of corridor lighting in 2nd floor of commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23038	17041-20000-40242	4416 N LIBBIT AVE	91436	5	165B137    30	2284010009	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Closed	10/31/2018 12:00:00 AM	ADDRESS	34.1526	-118.49492	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23039	13041-10000-23392	12219 W HART ST	91605	2	183B165   232	2321005048	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.19768	-118.3993	PV1 9.156KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-4.2-OUTD-US] [( 28) MOD: SUNPOWER spr-327ne-WHT-D]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23040	18041-10000-05727	18433 W ROSCOE BLVD #108	91325	12	192B125   578	2786022035	QC1-1VL, QP-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.22091	-118.53469	PC FOR POWER AND ENERGY FOR INTERIOR REMODEL TO (E) MEDICAL  OFFICE BUILDNG TO DEMISE 1 TENANT SPACE INTO 2 TENANT SPACES.SCOPE INCLUDES NEW SPACES  WITH NEW LIGHTS AND RECEPTACLES INCLUDING NEW CIRCUITS. TOTAL AFFECTED AREA 1270 SQ.FT.B#18016-20000-03650	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23041	18041-20000-06693	1553 N SCHRADER BLVD	90028	13	148-5A187 334	5547018029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Closed	07/11/2023 12:00:00 AM	ADDRESS	34.09953	-118.33258	replace existing lighting fixtures with new led.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23042	15041-20000-01047	14645 W GAULT ST	91405	6	183B149   138	2219007007	(T)(Q)RAS3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.19948	-118.45246	NEW 70 UNITS 4-STORY APARTMENT BUILDING OVER 2-LEVEL PARKING GARAGE (1 LEVEL ON GROUND AND 1-LEVEL SUBTERRANEAN) AND ATTACHED WITH NEW 7 UNITS 2-STORY APARTMENT BUILDING ON SOUTH SIDE OF THE BUILDING. 2500 AMP SERVICE.  FIRE VARIANCE ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23043	14041-20001-30638	8930 N CORBIN AVE	91324	12	195B117    34	2783025080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.23322	-118.56211	PC FOR CHANGES TO APPROVED SET OF PLANS. ADDITION OF ONE EXISTING UNIT TO BE RECONNECTED, CHANGE TO NEMA-1. RELOCATED UNIT TO SUBPANEL. ONLY NEED CHECK SINGLE LINE. NO OTHER CHANGES. CLOUDED DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23044	18041-30000-08161	3506 N BERRY DR	91604	2	159B173    92	2378028024	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.13546	-118.37809	Plan check for service upgrade 600A for SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23045	16041-10000-37015	835 S HILL ST # 6	90014	14	127-5A209 115	5144018033	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.04377	-118.25671	COMMERCIAL FIRST TIME TENANT.PC FOR TITLE 24 ENERGY AND POWER.SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES.TOTAL AFFECTED AREA OF 1160 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23046	05041-10006-20430	416 S SPRING ST	90013	9	129A211    75	5149023008	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			01/12/2010 12:00:00 AM	01/12/2010 12:00:00 AM		Permit Finaled	02/09/2010 12:00:00 AM	ADDRESS	34.04837	-118.24848	Supplemental is for changes to Previously approved plans.  Changes include new ckt in each dwelling unit bathroom, reconfiguration of bus duct disconnect and distribution board protection.  Minor changes to HVAC configuration.  Service Loads updated to reflect as-built.  Changes are clouded as delta 15 and delta 16.  P/C is for Power and Energy. (((((((((((((( Delta 17 on 1-12-10   Changes made are as follows: Fixture type F7 and F8 are changed, omited LCP and replaced by photo cell and time clock, re circuiting panel EHP1,))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23047	13041-20001-26009	16720 W RINALDI ST	91344	12	213B137   605	2682003007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.27902	-118.49636	((EXPEDITE FEES ONLY))PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS FOR 1 INVERTER. 4.2KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23048	13041-10000-30267	4624 W HOLLYWOOD BLVD	90027	13	147B197   481	5542014009	[Q]C2-2D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.0998	-118.29013	permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. TI to (e) deli. 1 story. no emergency and less than 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23049	19041-10000-36783	9354 N BURNET AVE 112	91343	7	198B145   462	2656021***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.24052	-118.46303	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.6KWac PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIS-1P3.6K-4G-US) WITH 14 MODULES(HANWHA Q-CELLS BLK-G5 315) CONNECTED TO EXISTING 125A PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23050	11041-20000-01611	924 S WESTWOOD BLVD #520	90024	5	135B153   539	4363019902	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	03/12/2011 12:00:00 AM	ADDRESS	34.06308	-118.44513	Plan check T24 Energy (general/emergency) lighting office TI suite #520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23051	15041-10000-15696	4700 W SUNSET BLVD 5th-6th floors	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			Reviewed by Supervisor	06/02/2015 12:00:00 AM	ADDRESS	34.09788	-118.29194	TI of portions of 5th and 6th floor of (E) medical office building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23052	15041-20000-11919	5695 S GOLDENEYE CT UNIT 3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.97898	-118.41086	Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL BE RELAVENT TO UNIT # 1 OF ADDRESS 5695 GOLDENEYE CORT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23053	16041-10000-43320	5715 N FIGUEROA ST UNIT 100	90042	1	151-5A229 170	5492001015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.10994	-118.19246	FULL PLAN CHECK. TOTAL AFFECTED AREA OF 2874 SQ.FT, OCCUPANCY LOAD OVER 100 PERSON FOR THE BARBER AND THE BAR (BOTH ARE SAME OWNER)SCOPE INCLUDES NEW PANELS, LIGHTS AND RECEPTACLES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23054	18041-10001-48894	22015 W TULSA ST	91311	12	207B101   587	2723005064	(T)(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.26706	-118.60723	SUPPLEMENTAL FOR FEE EXPEDITEPLAN CHECK FOR A ROOF MOUNTED 12.6KVA SYSTEM CONSISTING OF 2 CNTRAL INVERTER(SE7600H-US & SE6000H-US) WITH 42 MODULES USING P400 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23055	19041-20000-14019	12541 W VOSE ST	91605	2	183B161   340	2324032003	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.19857	-118.40673	INSTALLATION OF A NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.96KW DC/11.01KW AC CEC. SCOPE OF WORK INCLUDES (36) SUNPOWER 360W PV MODULES WITH INTEGRATED MICROINVERTERS, AND A 125A PV SUB PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23056	15041-20000-07449	23256 W GILMORE ST	91307	12	180B093   804	2036009021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.18721	-118.63285	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23057	18041-10000-12851	8560 N VAN NUYS BLVD	91402	6	192B149    10	2638001059	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.22626	-118.44915	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23058	16041-20000-06953	1901 S FIGUEROA ST	90007	9	124-5A205 194	5126003016	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.0343	-118.27237	Plan check for power and energy. Project is located in methane zone. New 4 LEVEL PARKING STRUCTURE WITH A MOTOR VEHICLE REPAIR ON THE BASEMENT LEVEL. New 2000A service and distribution. Basement level is a hazardous area per article 511. 199,640sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23059	15041-20000-25806	20346 W VIA MEDICI	91326	12	219B113   124	2701045005	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.29444	-118.57759	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consist of (1) inverter, and (13) modules. System is connecting to a 300-amp MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23060	13041-10000-13141	26500 S SENATOR AVE	90710	15	030B193    69	7411015036	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.05	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	33.78144	-118.30288	PV1 8.33 MICRO INVERTER 2 STORY HOUSE. [(34x) MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [ (34x) MODULE: yingli YL245P-29B]. nonSTANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23061	19041-20000-12825	4801 N WINNETKA AVE	91364	3	168B113   263	2175027038	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.15705	-118.57061	addition of (1) tesla ESS 5KW to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23062	15041-20001-23754	17501 W RAYEN ST	91325	12	195B129   200	2768026009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM			PC Approved	08/10/2015 12:00:00 AM	ADDRESS	34.23232	-118.51605	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 16 kWac and consists of (3) inverter, (84) modules, (1) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23063	17041-10001-41312	3701 W VISTA DEL VALLE DR	90027	4	156B197     2	5593002906	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.12434	-118.28432	[[[[4/4/18 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. ADDITION OF NOTES AND ADJUSTING LADWP AVAILABLE FAULT]]]]PC FOR SERVICE TO 600A 1PH 120/240 FOR PUBLIC WORK PROJECT. SCOPE INCLUDES NEW MAIN SWITCH BOARD AND CIRCUITS. B# 17020-10000-03113      17030-10000-07508	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23064	18041-10003-15830	1547 N HAZELWOOD AVE	90041	14	157-5A221 268	5474012002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			PC Approved	09/17/2018 12:00:00 AM	ADDRESS	34.12437	-118.2147	09/17/2018CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDES THE PV MODULE LAYOUT UNDER CLOUDED AREA. DELTA 2. PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (17) MODULES WITH OPTIMIZERS AND (1) INVERTER 3.8KWAC. TOTAL SYSTEM SIZE IS 3.8KWAC, 5.185 KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23065	18041-10000-17539	13640 W ROSCOE BLVD	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.2215	-118.42999	PC FOR TI POWER AND ENERGY AN EXISTING MEDICAL OFFICE. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 4373 SQ.FTB# 18016-10000-14777	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23066	12041-10000-30771	11335 W SANTA MONICA BLVD	90025	11	129B149   478	4261004013	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.04626	-118.44986	T.I TO DOLLAR LOADS. PLAN CHECK FOR T24. AND EMERGENCY LIGHTS 1502 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23067	14041-20001-03829	9507 N BECKFORD AVE PV1	91324	12	198B117    62	2762011014	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.24308	-118.5516	][][ expedited per applicant request ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH MAIN SERVICE PANEL. SYSTEM SIZED @ 8.75 kW DC, AND IS TRANSFORMERLESS, WITH (2) POWER ONE INVERTERS; PVI-3800-OUTD-US-A, PVI-3800-OUTD-US-A (35) MODULES ET-P660250BB, (1) LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23068	19041-10000-04038	2812 E CESAR E CHAVEZ AVE	90033	14	127-5A225 130	5180018017	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.04428	-118.20248	INSTALLTING 4 LED POLE LIGHTS FOR OUTDOOR PARKING LOT- T/24 ONLYTOTAL SQFT = 17052 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23069	16041-10000-16388	11961 W SAN VICENTE BLVD 1st-2nd flr	90049	11	129B145    76	4404025006	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	09/17/2016 12:00:00 AM	ADDRESS	34.05267	-118.47147	TI TO RETAIL SPACE. MAKE NEW BEAUTY SALON. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23070	16041-20000-10977	9755 N MONOGRAM AVE	91343	12	201B137   419	2677002010	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.24804	-118.49265	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (18) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23071	16041-30000-37318	5044 N BAKMAN AVE	91601	2	171B173  1066	2353013019	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.16205	-118.37722	Installation of fire alarm system in new 5 story 46 unit apartment building.  Total system size = 160 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23072	14041-10000-30179	6643 N VALJEAN AVE	91406	6	180B137   177	2233031040	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.1916	-118.48601	Title 24 plan check only.  Total area = 8,568 sq. ft.Replace HID lighting with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23073	13041-20000-15263	920 W DOWNEY WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.02063	-118.28879	LIGHTING FOR WALKWAY, ON UNIVERSITY CAMPUS. PC FOR T24 ENERGY ONLY. OLTG FORMS. PER SUPERVISOR REVIEW, T24 ONLY. NO PC REQUIRED.Edit: Permit issued under 13041-10000-17351	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23074	18041-20000-28188	5808 W SUNSET BLVD lvl 4	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	ti to an existing high rise building.  adding new lighting new controls to existing panels for a conference room.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23075	12041-10000-05465	1407 E VENICE BLVD	90291	11	111B149  1403	4242032002	[Q]R4-1XL	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Apartment			03/09/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.9962	-118.44906	NEW 2 STORY OVER GARAGE, 9 UNITS APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23076	19041-20001-25756	2844 N LAMBERT PL	90068	4	154-5A191  99	5580018033	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM			PC Approved	08/02/2019 12:00:00 AM	ADDRESS	34.11893	-118.31763	08-02-2019 Changes to an approved set of plan, Changes include relocation of electrical equipment. All changes has been clouded.Plan check onlyFees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23077	14041-10000-03678	3030 N BROADWAY	90031	1	138A223    68	5208004001		East Los Angeles				1998.00	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	PIN	34.07336607	-118.20943828	TI in an existing retail. Replace existing fixture with fluoresent. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23078	12041-10000-07437	459 S COMSTOCK AVE	90024	5	138B153   211	4359006016	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2012 12:00:00 AM	04/09/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.07429	-118.43281	Plan check for new 10KW roof mounted photovoltaic system. single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23079	18041-20000-36391	437 E KENDALL AVE	90042	14	148-5A231 135	5301007024	R1-1	East Los Angeles	Northeast Los Angeles	Hermon		1837.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	PIN	34.10181771	-118.18761616	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23080	18041-10001-31485	2517 S 12TH AVE	90018	10	123B185   512	5059007013	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.02	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM			PC Approved	09/25/2018 12:00:00 AM	ADDRESS	34.03376	-118.33095	FEE EXPEDITEPLAN CHECK FOR 7.6KVA SYSTEM CONSISTING OF 25 SOLAR MODULES WITH P400 POWER OPTIMIZERS, AND TESLA BACKUP BATTERY SYSTEM ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23081	18041-30000-00128	6560 W FOUNTAIN AVE	90028	4	144B185   157	5533001004	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			01/02/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.09412	-118.33247	Plan check for new fire alarm monitoring system. Total Fire alarm devices: 1 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23082	16041-10000-08975	3218 W MONT CLAIR ST	90018	10	123B189  1103	5052011018	RD3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.0295	-118.31926	PV1 rooftop solar installation 3.2 kW system (15) HiS-S260RG     (15) M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23083	16041-20000-43891	11069 W FENWAY ST	91352	7	201B173   256	2538017026	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.24823	-118.37272	PV1.  Install 16.53 kW roof mounted grid tied PV system.  (58) modules with Enphase M250 microinverters.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23084	14041-10000-05825	11001 W SANTA MONICA BLVD	90025	5	129B153   655	4324031017	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.04872	-118.44158	Remove HID light fixtures and replace with new fluorescent fixtures in existing auto repair space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23085	15041-20001-25830	10066 N SAN FERNANDO ROAD	91331	7	204B161   621	2537011004	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.25328	-118.40766	08-04-16 Changes to an approved set of plans. Changes include down size service from 400A to 200A and remove 5 Auto Lift(Car lift) from garage. Changes apply to delta 1 only{{{{{Plan check Title 24 only for Auto Body Shop. Total area: 3,269 sqft}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23086	13041-20000-11729	2365 N GLENDALE BLVD 1-16	90039	13	147A209    17	5439006034	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.09905	-118.25949	PLAN CHECK AND PERMIT FOR NEW LIGHTING FIXTURE IN WASHROOM/LAUNDRY. PC FOR T24 ENERGY ONLY. PERMIT FOR EQUIPMENT AND CIRCUITS. PERMIT TO BE ISSUED FROM THIS APPLICATION. WORK DONE IN LAUNDRY ROOM. TOTAL AREA 70 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23087	15041-20001-38204	14760 W ARCHWOOD ST	91405	6	180B149   152	2236003012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.19276	-118.45518	**Expedite Fee**PV1, roof mounted solar panel, 1.855kW DC system (7)modules #KU2656ZPA, (1)inverter:PVI-3.0-OUTD-S-US-Z-A  (E) INVERTER: FRONIUS IG 2000 NEG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23088	18041-20000-03184	5636 W BRIARCLIFF ROAD	90068	4	151-5A193 279	5587021013	RE11-1D	Central	Hollywood	Hollywood United	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.10883	-118.31319	Plan check for a PV1 roof-mounted PV system. System size is 9.3 kWac and consists of (29) AC PV modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23089	13041-20000-14796	13277 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW. USING 15 MODULES. ENPHASE MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23090	16041-10000-30622	1506 W 84TH ST	90047	8	097-5A195  64	6034022011	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Expired	10/10/2018 12:00:00 AM	ADDRESS	33.96261	-118.30285	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(16)MODULES-CANADIAN CS6P-260P(16)OPTIMIZERS-SOLAREDGE P300 (1)INVERTER-SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23091	17041-10000-36236	944 E PICO BLVD # 3	90021	14	123A211   265	5132018034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.03051	-118.24925	interior alaterationsREPLAVE HID WITH LED LUMINAIRESTITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23092	16041-10001-25117	1015 S FAIRFAX AVE	90019	10	132B177   710	5086001004	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			PC Info Complete	12/05/2016 12:00:00 AM	ADDRESS	34.05765	-118.36427	Changes to an approved set of plans. Changes include reducing the area of the scope from  3,194 sq ft to 1530 sq ft for the pastry/food prep areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23093	11041-10000-08182	1325 N ECHO PARK AVE	90026	13	139-5A209  98	5419029009	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	34.07769	-118.25699	title 24 for an existing restaurant. emergency lighthing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23094	14041-20000-18399	9301 N TAMPA AVE #168	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/08/2014 12:00:00 AM			Corrections Issued	07/08/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I. to unit #168 to relocate cash register and refinishing of tenant space; existing lighting. new lighting in entry way only. pc for t24 energy only.during verification scope of work no longer included new lighting. PC not required. closed application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23095	16041-10000-29981	3600 N BARHAM BLVD Z	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.13829	-118.34154	PC FOR ADDITION OF LAUNDRY CIRCUIT WHICH IS COMBO UNIT WASHER AND ELECTRIC DRYER. AND REPLACEMENT OF UNIT PANELBOARDS. THIS IS CONJUNCTION WITH 3 OTHER PLANS. PROJECT 1/4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23096	19041-20000-02332	1880 S CENTURY PARK EAST STE 615-617	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only in office space high-rise building. Suites 615 and 617 Tenate Improvement. Total area: 2087 sq ft. B#19016-40000-01471	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23097	15041-10001-03371	380 WORLD WAY T-09	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Change to an approved set by modifying the load and lighting switches. Note. All changes are under delta-4 only.(((Plan check for Title 24 only. Project space is retail. Space is located in Tom Bradley International Terminal (Space T-09). Total lighting area = 1277 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23098	19041-20000-42860	9441 N ENCINO AVE	91325	12	198B129    42	2766021014	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.24271	-118.51571	PV1.  Install 13.864 kW roof mounted grid tied PV system.  (42) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23099	16041-10000-26870	23397 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.15981	-118.6342	T-24, PLAN CHECK FOR ENERGY ONLY. TENANT IMPROVEMENTS OF (E) RESTAURANT WITH OUTDOOR DINING AREA. SCOPE INCLUDES NEW LIGHTS AND NEW RECEPTECLES. TOTAL EFFECTED AREA 4497 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23100	17041-10002-44778	4510 N BLACKFRIAR ROAD	91364	3	165B097    49	2076012033	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.15203	-118.62313	Changes to an approved set of plans for a PV system. Changes include relocating solar modules on the roof-layout, and adding a performance meter on the single line diagram. Note: Permit is paid under PCIS#17041-10000-44778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23101	18041-10000-22917	7101 W 80TH ST Floors-2, 3 & 4	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.96608	-118.41457	Plan check for T24 only, Bathrooms & Lighting Project Loyola Marymount University. Scope includes renovating RD (dorm) unit bathroom on 1st floor, (3) common bathrooms on 2nd, 3rd, and 4th floor. New lights and receptacles using existing circuits. Total area: 1373 SqrFt.(B# 18016-10000-00455)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23102	13041-10000-00977	380 WORLD WAY Space T34	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI 1ST TENANT FOR TOM BRADLEY TERMINAL. THE LARDER AT TAVERNPROPOSED 1813 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE  CONCESSION (The Larder at  Tavern).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23103	17041-30000-20748	301 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	33.77206	-118.27885	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 13,830 sq. ft.Note: Building permit has been issued under 17016-10000-01780	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23104	17041-10000-03138	2029 S CENTURY PARK EAST 29th FL-LOBBY	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY. INTERIOR RENOVATION OF PUBLIC LOBBY ON THE 29TH FLOOR. TOTAL AREA 265 SQ FT.B # 16016-10000-29549	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23105	11041-20000-04810	501 S SHATTO PL	90020	4	135B197   762	5077003032	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM	06/28/2011 12:00:00 AM		Permit Finaled	07/29/2011 12:00:00 AM	ADDRESS	34.06509	-118.29014	Chiller and cooler units replacement.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23106	11041-10002-13692	7234 N VARNA AVE	91605	2	186B157   619	2328028009	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.20216	-118.42458	PLAN CHECK ONLY FOR T-24 (ENERGY) FOR PREVIOUSLY PERMITTED PROJECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23107	18041-10000-01509	2400 S HOOVER ST	90007	1	124-5A201 334	5124008024	C2-1L-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.03405	-118.28379	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 4575 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23108	15041-20000-16544	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for Title 24 only. Project site is the lobby within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,041 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23109	15041-20000-30514	4837 E HUNTINGTON DR NORTH	90032	14	142-5A233  36	5213002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM			PC Info Complete	09/15/2015 12:00:00 AM	ADDRESS	34.08619	-118.17919	Plan check for Power and energy T.I. in existing space PAMC(Pacific Alliance Medical Center). Total area: 1200sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23110	17041-20001-22825	23634 W DRACO WAY	91307	12	186B093   629	2027014013	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.20285	-118.64154	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23111	16041-20000-14349	19901 S HAMILTON AVE STE C	90502	15	057B197    84	7351033034	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	33.84991	-118.28625	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 47020.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23112	16041-30000-40461	5030 W ROSEWOOD AVE 1-22	90004	4	141B189  1101	5522021028	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			11/15/2016 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.07919	-118.31463	Plan check for New Appartment builidng 22 units 4 story 800A and 400A Service. Total area: 19,072 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23113	17041-10000-32861	907 S OGDEN DR	90036	4	132B177   433	5086012019	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.05927	-118.36125	PC FOR ROOF MOUNTED PV ON SFD IN HPOZ. SYSTEM SIZE 5.5KW ACSCOPE INCLUDES 21 MODULES WITH 11 APSYSTEMS YC500I MICROINVERTERS.PC USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23114	19041-20000-05459	23631 W COMMUNITY ST	91304	12	192B093   182	2005018016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.22182	-118.64214	Plan check for Energy Storage System installed into existing PV System, Tesla Power Wall 2.0   13.5KWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23115	12041-10002-18048	1250 W HARRY BRIDGES BLVD MAIN EXIT-CANOPY	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM			Verifications in Progress	02/18/2014 12:00:00 AM	PIN	33.77046453	-118.27163726	PLAN CHECK FOR POWER AND ENERGY. SUPLEMENTAL APPLICATION FOR ADDING A NEW UTILITY ROOM# 2. ADDING 3 NEW PANELS. ONE TRANSFORMER. TOTAL AREA 127 SQ FT.(MEHDI) {{PLAN CHECK POWER FOR NEW MAIN EXIT CANOPY WITH LIGHTING FOR MAIN GATE CANOPY.  REAR BERTHS 136-139, MAIN EXIT. METHANE ZONE.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23116	12041-10000-09156	15301 W VENTURA BLVD D-100	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.15411	-118.46654	TENENT IMPROVEMENT title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23117	13041-20000-07106	3023 S WESTERN AVE PV	90018	10	120B193   522	5053006903	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	Apartment			03/19/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.02667	-118.30906	Plan check for PV system. Appartment. Three 6kW inverters. 19.11kW DC. PC fees per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23118	15041-20000-10347	10670 N DEERING AVE	91311	12	207B105   253	2706028002	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.26422	-118.59554	Plan check for a PV1 roof-mounted PV system. System size is 8.6 kWac and consists of (2) inverters, (47) modules, and (1) 125-amp load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23119	15041-20000-30634	7807 N TUJUNGA AVE	91605	6	189B173   640	2311010007	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.21234	-118.37923	PV1. Installation of new roof mounted solar array on existing single family dwelling.  Total system size = 4 kWac.  Two inverter system with interconnected battery bank feeding critical load panel and regular panel with new manual transfer switch.  Transfer switch and critical load subpanel to be included on seperate permit..	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23120	17041-20001-29156	13182 W CHESTERWOOD ST	91342	7	222B157   323	2512006027	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.30468	-118.42033	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 5 kWac and consists of (1) inverter, (18) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23121	14041-10000-24361	4605 N LANKERSHIM BLVD #500/520	91602	2	168B173   921	2421028013	C2-2	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.15405	-118.36832	Plan check for energy only. T24. No change in occupancy. Tenant improvement of offices. high rise. 10874 sq. ft. Emergency lighting. Suite #500/520, 5th floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23122	18041-20001-49189	13153 W TONOPAH ST	91331	6	195B161   665	2627022005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.22755	-118.41922	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGE OF DC SYSTEM SIZE TO 5.28 KW AND CHANGE OF PV MODULE FROM (17) REC SOLAR: REC290TP2 BLK TO (16) LG ELECTRONICS: LG330N1C-A5. CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23123	16041-20001-21249	10360 W DIAMOND ST LOT 21	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC in Progress	06/27/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23124	17041-20000-01714	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Issued	01/18/2017 12:00:00 AM	ADDRESS	33.97954	-118.41361	Plan check for the addition of (130) devices and (2) RPSs to an existing fire alarm system for an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23125	19041-10000-48771	9150 S LOYOLA BLVD APF	90045	11	093B161     3	4119006913	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	06/17/2021 12:00:00 AM	ADDRESS	33.95408	-118.41705	PLAN CHECK FOR A 500KW GENERATOR FEEDING AN 800A DISTRIBUTION BOARD TO SERVE AS A TEMP POWER FOR CONSTRUCTION SITE TRAILERS' SKIDS. SCOPE INCUDES (3) NEW 75KVA STEP DOWN TRANSFORMERS, AND NEW PANELBOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23126	15041-10000-31648	925 N LA BREA AVE	90046	5	144B181   708	5531016020	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.08803	-118.34436	NEW FIRE ALARM SYSTEM FOR A 6 STORY, MIXED OCCUPENCY BUILDING. TOTAL AMOUNT OF FIRE ALARM DEVICES IS 207. FEES PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23127	18041-20000-43829	17211 W BENNER PL	91316	5	165B133   145	2292017021	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.15055	-118.50788	pv1install roof mounted pv system sized 13.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23128	15041-10000-42476	1050 W CHILDS WAY	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.02262	-118.29103	Power plan check for adding a 1600-Amp generator tap box working as a addition stand by section for normal power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23129	10041-20000-07646	16945 W SHERMAN WAY	91406	6	183B133    24	2227003054	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			04/26/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.20137	-118.50233	Plan check power for new 30KW Photovoltaic System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23130	17041-10000-38763	1315 N LAUREL WAY	90210	5	144B161    48	4355018036	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	05/05/2020 12:00:00 AM		Issued	05/05/2020 12:00:00 AM	ADDRESS	34.09463	-118.41786	THIS IS PLAN CHECK ONLY, PERMIT IS COVERED UNDER BUILDING COMBO PERMIT. NEW SINGLE FAMILY DWELLING WITH BASEMENT AND ATTACHED GARAGE, 600A 120/240V SERVICE(B#15010-10000-00902)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23131	19041-10000-01061	6240 N LAUREL CANYON BLVD	91606	2	177B165   195	2334010022	C1-1L, P-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.18424	-118.39631	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23132	14041-10000-14120	523 W 6TH ST SUITE 1013	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	PLAN CHECK FOR ENERGY ONLY FOR OFFICE SPACE IN HIGHRISE BUILDING SUITE 1013	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23133	13041-10000-26073	3118 W SWAN PL	90026	13	145-5A205 331	5431033004	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.092	-118.27012	PV1.  Install 3.5 kW roof-mounted solar array, interconnect with main service panel.  1 transformerless inverter: SolarEdge SE3800A-US w/ power optimizers.  14 modules: Hanwha #HSL60P6-PB-4-250TW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23134	11041-10000-26259	8589 N SPARTON AVE	91331	6	192B157   212	2637011008	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2011 12:00:00 AM			Reviewed by Supervisor	01/03/2012 12:00:00 AM	ADDRESS	34.22564	-118.42964	INSTALL A 6.8KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE USING TRANSFORMERLESS INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23135	18041-30000-00427	11925 W WILSHIRE BLVD	90025	11	129B145   934	4265014095	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Issued	01/04/2018 12:00:00 AM	ADDRESS	34.04655	-118.46473	Plan check for new fire alarm panel. Replace existing Fire Alarm Panel and install 1 fire alarm device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23136	17041-10001-17289	5670 W WILSHIRE BLVD 23RD FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	Changes to approved set.  Relocate conference room and update lighting and power plans.  Existing panel to be replaced by two subpanels.  All changes clouded with delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23137	14041-20000-09136	15028 W COPPER ST	91345	7	207B145   121	2615009040	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.26717	-118.45895	PV1.  Install 3.225 kW (AC) roof-mounted PV system, interconnect with upgraded main service panel.  Microinverter standard plan.  Enphase M215-60-2LL.  15 modules: SunEdison F270	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23138	19041-10000-38717	6414 S MCKINLEY AVE	90001	9	105B205  1037	6007015027	M3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	10/12/2021 12:00:00 AM	ADDRESS	33.98126	-118.26127	Power plan check for a T.I. with new equipment rated at 800-Amp. Lighting Plan check is under a seperated permit, and portion of permit fee is paid under 18041-10000-38547. (((Pc for  title-24 (18041-10000-38547) , Energy only.Socpe includes new lights and receptacles. Total affected area is 9380 sq.ft.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23139	19041-10000-42185	3401 W SLAUSON AVE	90043	8	108B185   886	5006004022	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	33.98918	-118.33149	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23140	19041-10000-27733	3423 W JEFFERSON BLVD	90018	10	120B185   803	5051030030	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.02572	-118.33354	T-24, PC FOR Energy only. Change of use from auto repair to office & tenant improvement. Scope includes new lights and receptacles. Total affecte area is 12650 Sq. Ft. b#19016-30000-14225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23141	16041-10000-43616	300 S GRAND AVE 24TH FLR	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	PC for energy only to existing high rise building on 24th floor (offices). Installing new lighting and power. Total sqft = 500.Note: Permit is paid under PCIS#16041-90000-39825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23142	17041-10000-45110	3000 S ROBERTSON BLVD	90034	10	123B169   884	4311033015	C4-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM			PC Info Complete	12/15/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	PC FOR OFFICE TI ON THE FIRET FLOOR FOR TITLE 24 ENRGY ONLY.SOCPE INCULDES NEW CIRCUITS, EQUIPMENT AND LIGHTING. TOTAL  AFFECTED AREA 9486 SQ.FT. B#17016-10000-33202	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23143	14041-20000-32919	5735 N COLUMBUS AVE	91411	4	174B145   240	2243005006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.17491	-118.46418	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. TOTAL OF 18 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23144	10041-20000-00933	8335 W MELROSE AVE	90069	5	141B173   436	5528003198	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	02/08/2010 12:00:00 AM		Permit Finaled	03/31/2010 12:00:00 AM	ADDRESS	34.0838	-118.37143	Tenant improvement for (E) commercial bldg .  Retail Space  Electric and energy, fire alarm separate.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23145	15041-20000-01612	12945 N GLENOAKS BLVD	91342	7	222B149   490	2505018060	RA-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.30568	-118.44756	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.2kW (3.6+3.6). Ungrounded system.28  327W pv modules across 4 strings (7+8 on inv1; 6+7 on inv2).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23146	17041-30000-08200	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009198	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/14/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	33.95605	-118.38499	Plan check for a fire alarm system for a new apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (258) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23147	12041-20000-18266	16906 W LIVORNO DR	90272	11	126B121   269	4415016016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.04337	-118.54701	Photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23148	11041-10001-06658	3500 W WILSHIRE BLVD	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/06/2011 12:00:00 AM	ADDRESS	34.06157	-118.30077	REVISION TO PREVIOUSLY APPROVED PLANS; REVISE CKTS. FOR UNIT EQUIPMENT LIGHTING FIXTURES AND EXIT SIGNS.  (NO ADDITIONAL PERMIT ITEMS ISSUED FOR THIS REVISION)(T.I. FOR AN EXISTING RESTAURANT.  T-24 OTC PLAN CHECK ONLY.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23149	15041-10000-39689	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	RETAIL MALL KIOSK, new lighting. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23150	15041-10000-00654	18432 W TRIBUNE ST	91326	12	207B125   103	2715007035	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.26706	-118.53511	PV1 Standard plan, 6KW roof-mounted system including (1) 6KW SMA Sunnyboy 6000TL and (20) Phono Solar PS300p-24/T modules.Note. after being advised online services, customer insists for plan check over counter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23151	18041-20000-38379	3980 W WILSHIRE BLVD	90010	10	132B189    79	5092030039	(T)(Q)C4-2	Central	Wilshire	Wilshire Center-Koreatown		2126.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.06153	-118.31391	Fire alarm system for new 7-story mixed use building.  (867) devices, power supplies, and FACP.  Voice alarm communication system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23152	17041-20000-36312	2111 S LONG BEACH AVE WEST	90058	9	118-5A213 361	5118025003	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Issued	11/21/2017 12:00:00 AM	ADDRESS	34.01755	-118.24352	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 5000 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23153	12041-10000-22452	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Public Safety Only			09/20/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	NEW FIRE ALARM SYSTEM FOR A MOVIE THEATER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23154	14041-20000-28672	601 S FIGUEROA ST suite 4670	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for energy only. TI to office on 46th floor of an existing high rise office building. 3,850sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23155	19041-10000-11054	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT TO TERMINAL 6 AT ARRIVALS LEVEL TO CREATE BAGGAGE SERVICE OFFICE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL AFFECTED AREA IS 703 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23156	15041-20000-04594	9301 N WINNETKA AVE	91311	12	198B113   122	2748038032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM			PC Info Complete	02/17/2015 12:00:00 AM	ADDRESS	34.23934	-118.57134	TI TO AN EXISTING OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SUARE FOOTAGE 2390.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23157	11041-20000-25701	601 S FIGUEROA ST Ste 3875	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I.  Remodel of the light fixtures in Ste 3875.  Plan check is for energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23158	18041-10000-22205	7258 N CANOGA AVE	91303	3	186B105   631	2111029001	(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.20282	-118.59754	Tenant Improvement in an existing StarBucks. T-24 Energy ONLY.Building Permit: 18016-10000-18758	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23159	18041-10000-41994	8448 S LINCOLN BLVD	90045	11	096B157   278	4113014035	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.96096	-118.42001	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23160	10041-10000-08327	21611 W SATICOY ST	91304	3	186B105   141	2110021054	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Apartment			05/05/2010 12:00:00 AM	06/21/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.20844	-118.60101	New PV system for an appartment building. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23161	17041-10000-17172	201 N LARCHMONT BLVD	90004	4	138B189   682	5515018013	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.07478	-118.32383	Title 24 plan check only.  T.I. to existing take out restaurant.  New 100 amp subpanel with lighting and receptacles.  Total area = 407 sq. ft.       Building permit #17016-10000-12203	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23162	17041-10000-45547	3531 S PURDUE AVE	90066	11	117B157   664	4249028025	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.01501	-118.42525	Install New rooftop solar system an an SFD, (17) modules with (17) power optomizer P320,  (1) inverter, systen size 5kW AC/ 5.355kW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23163	19041-20000-29052	8378 N COZYCROFT AVE pv1	91306	3	192B109   516	2780024013	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.22227	-118.58201	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.(1) LG CHEMRESU 10H Battery	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23164	19041-20000-41128	20811 W PINECONE CIR UNIT #16	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.29583	-118.58732	PV1. INSTALL 4.20 KW DC PV SYSTEM WITH (12) MODULES/MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23165	16041-10001-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Closed	04/10/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	SUPPLEMENTAL TO EXISTING ELECTRICAL APPLICATION - PLAN CHECK FOR POWER AND ENERGY SCOPE OF WORK INCLUDING 800 A SWITCHBOARD WITH 3 LEVELS OF PARKING GARAGE, TOTAL SQ FT. 147900. Note :   Service equipment permit on 16041-10000-43693   1035 N Swarthmore Ave	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23166	15041-10000-02806	811 S CARONDELET ST	90057	1	132A201   143	5141025027	(T)(Q)C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.0564	-118.28261	New fire alarm system with (1) fire alarm, ( 2) Power supplies, (1) annunciator & 130 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23167	16041-10000-13366	11410 S WADSWORTH AVE	90059	15	087A209   459	6072027013	RD2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Expired	05/18/2018 12:00:00 AM	ADDRESS	33.93029	-118.25848	PV2, New  rooftop solar installation on a 3-unit residential, PV system is feeding one unit.   (1) SE3000A   (14) Solar city standard modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23168	12041-10001-04614	9301 N TAMPA AVE #216	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	CHANGES TO APPROVED SET OF PLANS-ADDED A N INFRA-TECH CONTROL PANEL TO SUPPLY AND CONTROL TWO NEW PATIO HEATERS AND NEW POS STATIONS(((((((((Change of use from commercial to a new restaurant.  New switchboard,  panels,  loads, circuits, receptacles, lighting.  Variance will be submitted to seperate the fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23169	15041-10000-14184	200 WORLD WAY SPACE 281	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	INSTALL STARBUCKS LED SINAGE NOT VISIBLE FROM ROW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23170	17041-20001-15396	13052 N DRONFIELD AVE	91342	7	222B153    31	2509020002	(Q)R3-1, RA-1	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Apartment			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.30805	-118.43722	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. CHANGES INCLUDE CHANGE OF CIRCUIT BREAKER TYPE AND ELEVATOR HP RATING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23171	16041-20000-29590	10042 N FULLBRIGHT AVE	91311	12	204B113   553	2741020003	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.25312	-118.57778	PV1.  Install 8.64 kW roof mounted PV system.  (36) modules with Enphase M250 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23172	13041-20000-03916	505 S SAN PEDRO ST 1-108	90013	9	127-5A213 232	5148012019	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			02/14/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	34.04392	-118.24444	"Plan check for PV. Apartment. Plan check fees per customer, please verify during final fee period. ""PV AC Combiner"" Panel is existing (125A bus). 25.25kW DC."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23173	16041-20000-31709	20715 W SCHOOLCRAFT ST	91306	3	183B109   587	2137025009	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Issued	09/07/2016 12:00:00 AM	ADDRESS	34.19675	-118.58455	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (26) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23174	16041-20001-10568	9041 W CATTARAUGUS AVE	90034	5	123B169   385	4301003032	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	34.03515	-118.39007	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23175	13041-20000-22944	7725 N DELCO AVE	91306	3	189B109  1013	2107014015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.21099	-118.57886	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5 KW USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. PC REQUIRED. TOTAL OF 24 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23176	18041-20000-09477	1257 N VILLA WOODS DR	90272	11	129B129   156	4409004007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	05/25/2019 12:00:00 AM	ADDRESS	34.05194	-118.5149	INSTALLATION OF ENERGY STORAGE SYSTEM TO EXISTING PV SYSTEM. SYSTEM SIZEL 26.4 KWH	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23177	17041-10000-04025	310 N MADISON AVE	90004	13	138B197   243	5501002034	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.0768	-118.28902	PC for energy only for TI for new offices. Total affected area is 13772 sqft. Installed load under 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23178	18041-10000-37426	2805 S SAN PEDRO ST	90011	9	118-5A207 124	5128013028	CM-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	34.01977	-118.26268	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23179	15041-10003-14620	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM			PC Approved	10/17/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 36 ON PLANS. REVISED CONNECTION OF AH UNITS ON SINGLE LINE. PC ONLY. RECHECKING THE REVISED LOADS. THIS IS RECHECK FOR PACKAGE 4 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23180	16041-10001-19951	10537 W SANTA MONICA BLVD 2nd Floor	90025	5	132B157   951	4326033041	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.05512	-118.42802	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. REVISED CORRIDOR LIGHTING. UPDATED T24 DOCUMENTS PROVIDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23181	09041-10002-24382	10329 W PALMS BLVD	90034	5	120B161   400	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2699.07	Electrical	Electrical	Apartment			06/18/2013 12:00:00 AM			PC Approved	06/19/2013 12:00:00 AM	ADDRESS	34.02679	-118.40832	MODIFICATION TO APPROVED SET OF PLANS 09041-10000-24382. ALL CHANGES ARE DELTA 2 CLOUDED. TITEL 24 NOT IN SCOPE OF PLAN CHECK OR CHANGES. TITLE 24 CHANGES ADDRESSED UNDER APPLICATION NUMBER 09041-10001-24382.*************************************************************************09041-10000-24382. DESCRIPTION: New Mixed Use project - core for retail / apartment (3-7 typical; 31 units) / parking - Permit is for new service (120/208), new distribution, new panels, new equipment, new ckting for residential / commercial use.  P/C is for Power and Energy. Modification to seperate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23182	15041-10000-14575	6430 W SUNSET BLVD STE-1025	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.09782	-118.32979	Energy plan check for an office TI located at suite-1025 of a high rise building. works includes new panel, lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23183	13041-10000-35380	807 E 12TH ST STE 132	90021	14	123A211    42	5132009013	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.03247	-118.25043	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH FLUORESCENT FIXTURES. 448 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23184	18041-20002-15077	7600 N BALBOA BLVD STE 109	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM			PC Approved	03/22/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	Change to an approved set of plan, Changes include revised electrical load on panel schedule and equipment on roof. Plan check only, permit fees covered under master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23185	18041-10000-33183	4800 S COMPTON AVE	90011	9	111A211    39	5106018010	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.00006	-118.2476	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23186	13041-10000-25071	3586 S OCEAN VIEW AVE	90066	11	114B153   605	4248024008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.009	-118.43586	PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 8.25KW DC IN A SINGLE-STORY HOME. TRANSFORMERLESS INVERTER.(33) TRINA #TSM-250(2) INVERTER: POWER-ONE: PVI-3.6, PVI-3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23187	15041-10001-36577	777 S SANTA FE AVE TOWER	90021	14	124-5A217 270	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.03354	-118.23024	09/29/16Changes to an approved set of plans. All changes are clouded under delta 5. Changes include removing 5 duct smoke detectors, and revising battery calculations. Note: Permit is paid under PCIS#15041-10000-36577((((((Installation of new fire alarm system in Ford Factory.  This is for TOWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23188	14041-20000-06657	1515 W 190TH ST STE 350	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.85852	-118.30531	T.I. to existing office building.  Install new panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23189	17041-20000-14632	8945 N NEVADA AVE	91304	12	195B101    50	2010021008	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.23329	-118.60775	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (37) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23190	14041-10000-35344	18060 W CHATSWORTH ST 1-6	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.26446	-118.52593	T.I. to existing commercial space.  Title 24 plan check only.  Total area = 38,023 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23191	18041-10001-26999	2945 S MINER ST	90731										Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	33.71621	-118.27584	NEW 1167.9 KW PV SYSTEM MOUNTED ON CARPORTS WITH 2685 PV MODULES AND 32 INVERTERS WITH 480 VOLT OUTPUT. <<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03429	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23192	16041-10001-44696	620 S VIRGIL AVE 100	90005	10	135A201   140	5077007029	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM			Reviewed by Supervisor	02/02/2018 12:00:00 AM	ADDRESS	34.06288	-118.28683	REVISIONS TO PERMITTED SET OF PLANS. ALL CHANGES MARKED UNDER DELTA (TBD). SCOPE INCLUDES VARIOUS CHANGES TO EQUIPMENT, CIRCUITS AND LIGHTING. T-24 FORMS AND PANEL SCHEDULE REVISIONS (((((((Plan check for power and energy. Project scope is a first time tenant/tenant improvement for a new Target retail store with a Starbucks coffee shop. Total lighting area = 31,447 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23193	10041-20000-25700	333 S HOPE ST 54th floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.05326	-118.25292	T.I. to a high rise building partial of 54th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23194	13041-10000-11964	215 E 4TH ST	90013	14	129A213   223	5148002026	C2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	10/16/2014 12:00:00 AM		Issued	10/16/2014 12:00:00 AM	ADDRESS	34.04701	-118.24551	New 2-story retail building.  Ground level retail tenant spaces, basement floor, and 2nd story parking.  New service and distribution system.  Applicant submitted one set of plans for this application and 380 S Los Angeles St with application # 13041-10000-11969	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23195	13041-20000-36007	12320 W MONTAGUE ST	91331	7	204B165   270	2537014034	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.25412	-118.40082	pc for new 1600A, 480V service and distribution for existing warehouse. New loads and machinery. no lighitng loads. PC for Power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23196	18041-10000-25562	3020 S CRENSHAW BLVD	90016	10	120B185   560	5051029003	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.02685	-118.33491	PLAN CHECH FOR T24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23197	13041-10000-36296	505 S FLOWER ST #B-15	90071	14	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.0515	-118.25654	T24 PART 6 ENERGY FOR (E) RESTAURANT IN HIGH-RISE BUILDING. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 2132 SQ FT . EMERGENCY LIGHTING FED VIA (E) EMERGENCY CKT PER APPLICANT. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.NOTE: PERMIT FEE ALREADY CALCULATED UNDER INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23198	14041-10002-13424	5601 N DE SOTO AVE 2nd Floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM			PC Approved	09/18/2014 12:00:00 AM	ADDRESS	34.17126	-118.58861	Change to approved set including new control devices and (2) new circuits; total 1kw.(((T.I. to existhing building (Kaiser Permanente) on 2nd floor of none patience care area.  Install branch circuits and lighting.  Plan check for power and energy. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23199	12041-10000-07566	3187 S ALAMEDA ST	90058	9	115-5A215  12	5117017015	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.01068	-118.23993	new offices in part of an existing warehouseplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23200	19041-20000-41377	11865 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	09/26/2021 12:00:00 AM	ADDRESS	34.28584	-118.38976	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23201	14041-20000-17412	21600 W OXNARD ST 19th floor	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for energy only. Relocate existing lighting on 19th floor of existing high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23202	15041-20000-29388	11767 N CHIMINEAS AVE	91326	12	216B125   286	2870019035	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.28508	-118.53351	PERMIT FEES $0.00 BY STATE SENATE BILL#1222.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (58) modules, (1) combiner box, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23203	17041-10000-37664	624 S GRAND AVE PWR DIST-SYSTEM	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	Power infrastructure for IT power and cooling loads; refeed two existing MV swgrs on the 30th floor from new electrical equipment; Exterior utility 34.5 KV SERVICE EQUIPMENT FOR NEW 10MVA DWP SERVICE. New luminaires on all floorsTwo 3.1 MW standby parralel gensets; Interior 4160KV distribution swgrs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23204	12041-20000-03869	8120 N WOODMAN AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.21871	-118.43098	New medical office bldg.  Variance to separte the fire waring system from the electrical system was submitted on october 22, 2012.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23205	16041-10000-43512	1041 W 45TH ST	90037	9	111B197   211	5017032013	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.00278	-118.2931	PC FOR PV SYSTEM 5KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. USING 19 MODULES. roof mounted	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23206	19041-20000-25145	12457 W VENTURA BLVD ste 101	91604	2	162B165   228	2367018017	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.14287	-118.40495	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plamn check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23207	13041-10000-35834	4501 S BROADWAY	90037	9	112-5A203 213	5110004004	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	10/31/2014 12:00:00 AM		Issued	10/31/2014 12:00:00 AM	ADDRESS	34.00277	-118.27861	PLAN CHECK FOR POWER ADN ENERGY . REVISION TO PLAN - REDUCE SCOPE OF WORK. PREVIOUS ELECTRICAL PC #08041-10001-22305BUILDING PERMIT # 08010-10002-02520	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23208	17041-10000-15111	5510 S LINCOLN BLVD SUITE 160	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM			Ready to Issue	06/26/2017 12:00:00 AM	ADDRESS	33.97299	-118.43051	PC FOR RESTAURANT TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23209	14041-10000-19103	3945 S CRENSHAW BLVD	90008	10	117B185  1159	5032002059	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.01348	-118.3355	T24 ONLY.TI, BANK OF AMERICA. 1204 SQFT.NOTE: Changes were made to the approved set of plans. Updated plans are dated 1/21/2015. Plans dated 9/2014 are outdated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23210	10041-10001-15467	457 S MARIPOSA AVE	90020	10	135B197   757	5502015014	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Public Safety Only			09/21/2010 12:00:00 AM			PC Approved	09/21/2010 12:00:00 AM	ADDRESS	34.06558	-118.29937	REPLACE EXISTING FIRE WARNING PANEL WITH SAME MODEL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23211	16041-20000-06459	7027 N ETON AVE	91303	3	183B105   564	2138015025	MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.19819	-118.59559	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23212	14041-20000-16625	4927 N GLEN IRIS AVE	90041	14	160-5A223 135	5686015010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.13488	-118.21004	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(14) RENESOLA MODULES 250M WITH POWER OPTIMIZERS.(1) SOLAREDGE INVERTER SE3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23213	13041-20000-30907	1416 N LA BREA AVE	90028	4	147B181   794	5548017021	[Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.09656	-118.34388	New 199KW rooftop PV system for an existing commercial building.(((( $0 permit fee is due to the 2012 Senate Bill No. 1222)))))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23214	16041-20001-02576	16430 W TUPPER ST	91343	12	198B137   571	2676025006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.23922	-118.49054	EXPEDITE PER APPLICANT REQUESTInstall a solar array on a SFD, interconnect with a 200A MSP (derating main to 175A). There is an existing system on roof rated 3kW. New system is rated 6kW, ungrounded. (25) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23215	10041-10001-22828	2233 E CESAR E CHAVEZ AVE	90033	14	129A223   232	5175011027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2036.00, 2044.20	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	05/22/2012 12:00:00 AM	ADDRESS	34.04752	-118.20903	Modification to previously approved set of plans.  Changes to Indoor & Outdoor lighting, equipment (AC on roof), outlet locations, and reconfiguring circuit loads on panels.  <<<<<<New Walgreens Store.  Plan Check is for Power and Energy.>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23216	19041-20000-48531	18321 N MAYERLING ST	91344	12	219B125   114	2601074021	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.29555	-118.52886	PV1.  Install 11.55 kW DC roof mounted grid tied PV system.  (30) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23217	18041-10000-13968	13760 W FOOTHILL BLVD #E	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM			PC Info Complete	04/18/2018 12:00:00 AM	ADDRESS	34.30934	-118.43312	PC FOR TITLE 24 ENERGY ONLY FOR A CHANGE OF USE FROM RETAIL TO BOBA SHOP/COFFEE SHOP (CAFE).SCOPE INCLUDES NEW PANEL, EQUIPMENT LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 619 SQ.FT. B#18016-10000-07306	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23218	11041-10000-22289	1457-1463 W COLORADO BLVD	90041	14	162A227    83	5691003013	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Public Safety Only			10/18/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.13954	-118.1965	NEW FIRE WARNING SYSTEM FOR 3-STORIES MIXED USED BUILDINGI FIRST FLOOR WITH OFFICES AND 2ND AND 3RD FLOORS APARTMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23219	15041-20001-27596	5441 N YARMOUTH AVE Unit #10	91316	5	174B129   960	2162010006	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Apartment			10/13/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	34.16964	-118.52051	Installation of roof-mounted solar PV system in a 11-unit apartement build. This scope is on the #10 Unit.Total system 2.8kW DC.  Permit under 15041-90000-27596	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23220	10041-20000-04008	1600 N CAMPUS ROAD TRAILER 1	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	06/24/2010 12:00:00 AM	PIN	34.12750533	-118.21285206	TEMPORARY TRAILER  (TRAILER 1)  OCCIDENTAL COLLEGE, JAMES SWAN HALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23221	17041-20003-03041	8800 S HOOVER ST	90044	8	096A201    80	6038013900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	33.95787	-118.28682	Revision to approved set of plans.  Revised plans for renovation work in portions of pool house not under scope of previous permit.  New 200A subpanel.  Plan check for power and energy.  (((Partial renovation of community pool and pool house.  800A 240/120V 3ph-4w service replacement.  Plan check for power. Title 24 Part 6 plan review under original master permit.)))(((New outdoor lighting for pool facilities and interior lighting for pool house pump rooms and lifeguard room.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23222	14041-20000-15118	829 N KENMORE AVE	90029	13	141B197    23	5538009007	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.08673	-118.29714	New roof mounted PV system with optimizers and transformerless inverter.  Total system size 5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23223	15041-10001-17218	260 S LA BREA AVE	90036	5	135B181   125	5513023006	C2-1LD, [Q]C2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM			PC Approved	04/22/2016 12:00:00 AM	ADDRESS	34.06965	-118.34383	04/22/16Changes to an approved set of plans. Scope includes adding manual area controls and occupancy sensors for two storage areas in the mezzaine level. NOTE: Permit paid under PCIS#15041-10000-17218(((((Energy plan check for commercial (Ralph's #039) interior T.I. Scope of work is for new storage area;  Electrical inspector verifies Starbucks (prefabircated unit) store to be exempted from plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23224	16041-10001-24115	19755 W NAPA ST	91306	3	192B117    45	2782018015	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.22643	-118.56425	NOTE: PLAN CHECK FEES ARE $0 DUE TO SENATE BILL 1222.07/26/16Changes to an approved set of plans. Changes include relocating the main service equipment (Main service panel, meter, and AC disconnect) from the inside of the garage to the exterior of the house. NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-24115(((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(28)MODULES-LG ELECTRONICS: LG310N1-G4(1)INVERTER-ABB UNO-7.6-TL-OUTD-S-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23225	17041-10000-19327	18425 W INGOMAR ST	91335	12	189B125   949	2102016086	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.21214	-118.53432	Energy plan check for removing HID fixture and replace with new LED Fixture in a commercial parking area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23226	11041-10001-15257	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			Corrections Issued	08/06/2011 12:00:00 AM	PIN	33.94363002	-118.42513364	T.I.  Federal Express Hangar.  1 out of 3 applications.  This application deals with the Title-24 calculations within the hangar and the new 2-story modular unit that is to be permanently installed.  The power portion (single line diagram) of the project along with showing the lighting side of the office space that is to be remodeled is under 11041-10000-15257.  The  plan set that shows two of the panels for the modular unit (LHIN and  MOD)  as  well as the floor plan and power plan for the modular unit is under 11041-10002-15257.  Plan check is energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23227	16041-20000-02878	7900 N BALBOA BLVD BLDG 'H'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	Plan check for power and energy Aircraft Hangar Building 'H' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' H' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23228	13041-10000-20908	804 S LOS ANGELES ST	90014	14	127-5A211 318	5145013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.04164	-118.25241	TITLE 24 WORK IN A RETAIL STORE; REMOVING EXISTING LIGHT FIXTURES & REPLACING IT WITH NEW LIGHT FIXTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23229	14041-20001-29253	22333 W BURTON ST	91304	3	192B101   696	2012023014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM			Reviewed by Supervisor	10/31/2014 12:00:00 AM	ADDRESS	34.21876	-118.61342	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYTEM. MICROINVERTER NON STANDARD PLAN. SYSTEM SIZE: 9KW.(36) SOLAR WORLD PLUS 270 MONO(36) ENPHASE M215-60	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23230	14041-20000-05052	1183 N VERMONT AVE	90029	13	144B197   367	5540019019	RD1.5-1XL, [Q]C2-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.09304	-118.29194	T. I.  AND  CHG OF USE FROM RETAIL TO LAUNDRY.PC FOR POWER AND ENERGY. NEW LOAD GREATER THAN 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23231	18041-20002-08676	7600 N BALBOA BLVD 201	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Revisions to approved set of plans.  Change of lighting fixture with revision of Title 24 forms. (((SUPPLEMENTAL PLANCHECK FOR POWER DUE TO FIRST TIME TENANT  AND CHANGES TO T24 ENERGY.  MASSAGE PARLOR.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23232	19041-10000-10813	333 S GRAND AVE 820	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Info Complete	03/26/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	Energy plan check for an office tenant improvement to an existing office located in a high rise building. Scope includes new lighting and equipment with a total area of 1,670-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23233	14041-10000-32882	929 W JEFFERSON BLVD	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			11/26/2014 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.02454	-118.28542	Full plan check for power and energy. Project site is a new 4-story undergraduate student dormitory. Indoor lighting area = 213,159 sq. ft. Outdoor lighting area = 9,645 sq. ft. Total lighting area = 222,804 sq. ft. There are 8 typical units for a total of 157 units.(78 Ltg/Gen Rec Circuits need to be pay before pulling a permit)Note: Electrical plan check application has been initiated under the address 3131 S. Hoover Street, but the address will change (possibly to 929 W. Jefferson Blvd, Los Angeles, CA. 90007) once the project nears completion.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23234	19041-10000-51152	8720 N BALBOA BLVD	91325	12	195B133   419	2688041038	C1-1VL, C2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	07/31/2020 12:00:00 AM		Permit Finaled	01/28/2021 12:00:00 AM	ADDRESS	34.22939	-118.50239	PLAN CHECK FOR TITLE 24 ONLY. SCOPE OF WORK INCLUDES ADDITIONAL LIGHTING FIXTURES  TOTAL AFFECTED AREA: 1044 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23235	13041-20000-16539	17814 W ARVIDA DR PV-1	91344	12	219B129   276	2601050029	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.29823	-118.52169	PV-1. Two inverters one 5kW and one 6kW inverter. Ground mounted, transformerless system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23236	16041-20000-10182	14226 W VICTORY BLVD	91401	6	180B153  1097	2240013006	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.18638	-118.4432	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.68 KW , 400 AMP SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23237	18041-10000-16042	1060 N SWARTHMORE AVE # 2-102	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.04803	-118.52474	"PC FOR FIRST TIME TENANT "" ALO YOGA""  IN PALASIDES VILLAGE MALL FOR POWER AND ENERGY. SCOPE INCLUDES NEW  PANEL, CIRCUITS AND EQUIPMENT.TOTAL AFFECTED AREA 3313 SQ.FT B#18016-10000-12933."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23238	19041-10001-40781	11338 W STRATHERN ST	91352	6	189B173   244	2314014062	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.21555	-118.37826	PLAN CHECK ONLY. RELOCATING THE MAIN SWITCH BOARD ONLY. ***Plan check for a PV1 8.175 KW AC roofmounted system. Scope includes (1) load center, (25) microinvetrter and module interconnecting through the service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23239	15041-10000-35269	8533 N WOODLEY AVE	91343	12	192B137   107	2689025027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Closed	11/07/2016 12:00:00 AM	ADDRESS	34.22563	-118.48545	PV1, ROOF MOUNTED SOLAR SYSTEM, TOTAL SIZE IS 18.36-DC. (72) MODULES AND (72) MICROINVERTERS. (72) REC SOLAR MODULES REC255PE(72) ENPHASE M215-60-2LL-S22-IG *** $0 due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23240	17041-10000-37494	5161 N LANKERSHIM BLVD B102	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.16452	-118.37469	title 24 energy only for office area of a fitness center in suite B102 in the basement area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23241	12041-10000-00784	10880 W WILSHIRE BLVD #100	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	New 300KVA UPS for a data room located in the lobby area suite 100.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23242	19041-10001-29650	1371 N EUBANK AVE	90744	15	036B209   611	7422017900	OS-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM			PC Approved	08/03/2020 12:00:00 AM	ADDRESS	33.79125	-118.25641	PV2. NEW SOLAR SYSTEM SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 31.2KWdc / 22.8KWac.(96)MODULES- JIMKO JKM325PP-72V(2)INVERTERS- PIKA X11402(12)OPTIMIZERS- PIKA PV LINK(2)BATTERIES - PIKA HARBOR 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23243	17041-20000-22031	1880 S CENTURY PARK EAST Suite 608	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for energy only. TI to office suite 608 in high rise building. New lighting (incl. emergency) - 3,962sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23244	16041-20000-18142	5900 W WILSHIRE BLVD 29th Floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for Title 24 only in existing high-rise T.I. 29 FL. Total area: 6,706 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23245	16041-10000-40666	1101 S BLAINE ST	90015	1	129A205   379	5137022016	[Q]C2-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.04581	-118.27129	PC for energy only. Remove HID fixutres and replace with new LED fixtures. Total sqft = 19680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23246	16041-30000-21248	1500 W GLEN AYLSA AVE	90041	14	160-5A227  36	5689023020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.13583	-118.19838	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23247	19041-10000-08332	13161 N TELFAIR AVE	91342	7	225B141  1502	2604002053	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.30947	-118.47954	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23248	12041-20000-29965	10000 N LASAINE AVE	91325	12	204B129   518	2734030023	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.25213	-118.51214	PV-1. Plan check for Enphase. 11.44kW. Montenegro Residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23249	14041-10000-08922	14756 W ARCHWOOD ST	91405	6	180B149   153	2236003015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.19275	-118.45502	PV1, INSTALL 5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(20) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23250	16041-20000-00037	1622 N WILCOX AVE	90028	13	148-5A187 245	5546007006	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Issued	01/05/2016 12:00:00 AM	ADDRESS	34.10042	-118.33085	Plan check for fire alarm system. Installing new fire alarm system in a commercial building (hotel). Installing 1 panel and 128 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23251	10041-20001-16025	10889 W WILSHIRE BLVD RESTROOM	90024	5	132B153   290	4363022019	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM			PC Approved	09/08/2010 12:00:00 AM	ADDRESS	34.05908	-118.44352	PLAN CHECK ONLY. PLAN CHECK T-24 ENERGY FOR RESTROOM. EXISTING WIRING. EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23252	15041-20000-15447	1011 7TH ST	91340										Electrical	Electrical	Apartment			05/20/2015 12:00:00 AM			PC Approved	05/20/2015 12:00:00 AM				CITY OF SAN FERNANDO REQUESTED PLANCHECK ONLY   for fire alarm for 16 unit apartment. 3 story. 1 Facp and 87 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23253	09041-20001-13767	6100 N WOODLEY AVE Building 4	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.18088	-118.48309	revision as built drawings delta 1 by inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23254	13041-20001-35790	542 E ROSE AVE	90291	11	111B141   333	4240010008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	33.99853	-118.47286	Modification to approved set. Remove two meter sections, replace with new 400A panel section for future loads. Plan check Delta 2 changes. Verify work space clearances on field.[New mixed use with 2 residential units and retail space.  Full Plan Check for Power and Energy.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23255	13041-10000-00352	5855 W CENTURY BLVD GroundFlr	90045	11	090B169    11	4125025039	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM			PC Approved	01/07/2013 12:00:00 AM	ADDRESS	33.94572	-118.38488	reconstruction of a fitness center inside a highrise hotel. 2675 sq ft title 24 and power plan for relocated pannel and new with existing branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23256	16041-10000-45180	1605 W GRAFTON ST	90026	13	141A209   245	5419009018		East Los Angeles	SILVER LAKE-ECHO PARK- ELYSIAN VALLEY	GREATER ECHO PARK ELYSIAN	YES	1974.20	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	03/08/2023 12:00:00 AM	ADDRESS	34.08087	-118.25524	FULL PC FOR NEW MIXED USED APARTMENT BUILDING (35 STUDIO DWELING UNITS AND 3 RETAIL UNITS) 3 STORIES. SERVICE @ 3PH 2000A 120/208V. Building #16010-10000-04687.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23257	19041-20000-51170	10578 W OHIO AVE	90024	5	132B157   543	4326022008	R1-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.05809	-118.43155	PV1. INSTALL 10.89 KW DC PV SYSTEM WITH (33) MODULES/OPTIMIZERS AND (1) INVERTER(SE11400H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23258	18041-20000-40710	5161 N DUMONT PL	91364	3	171B109   238	2166016008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.16302	-118.58002	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23259	17041-10000-30182	550 W 127TH ST	90044	15	081B201   233	6132002026	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.91745	-118.28472	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL SPACE. SCOPE INCLUDES ADDING 306 FA DEVICES, AND 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23260	15041-20001-14776	1901 N VISTA ST	90046	4	150B181   228	5572026002	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2015 12:00:00 AM			PC Approved	06/24/2015 12:00:00 AM	PIN	34.1055072	-118.35236837	6.24.2015 - Changes to approved set. Change interconnection point from MSP of adjacent property to MSP of SFD on same parcel as ground mounted solar array. Changed address from 1900 to 1901 N Vista St. Service panel is same rating, no change to system design, only interconnection location.[Plan check for a ground-mounted PV system. System size is 16kW and consists of (2) inverters, and (48) modules.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23261	14041-20001-24306	18701-18729 W REDWING ST	91356	3	174B121   812	2161026005	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			01/20/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.16963	-118.54066	REVISIONS TO AN APPROVED SET OF PLANS.  RELOCATION OF EXISTING SERVICE AND NEW ALUMINUM FEEDERS TO EXISTING PANELS.NEW CONSTRUCTION FOR 15 APARTMENT UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23262	17041-10001-29816	19640 W HORACE ST	91311	12	207B117    89	2708011012	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.26696	-118.56196	EXPIDITED PER APPLICANT REQUEST. **************************************************PC FOR ROOF MOUNTER PV (WITH BATTERY) ON SFD. TOTA L PV SIZE 19.8KW DC / 15.2KW AC. CENTRAL INVERTER SYSTEM. SCOPE INCLUDE 60 PV MODULES WITH OPTIMIZERS2 (DC SIDE) BACK UP BATTERIES, 3 SUBPANELS (BACKUP AND LOAD CENTER).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23263	18041-10001-40703	7400 N COLDWATER CANYON AVE	91605	2	186B161   521	2324001011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.20498	-118.41362	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23264	14041-20000-01277	4408 E WORTH ST	90063	14	135A229   166	5224005014	M3-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.06245	-118.18956	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23265	13041-10000-34103	7333 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	33.94247	-118.42449	NEW PARKING LOT LIGHTS IN SECURITY BADGE OFFICE PARKING LOT IN LAX AIRPORT. AREA IS LOCATED IN METHANE ZONE. NEW UNGRND CONDUIT RUNS APPROXIMATELY 123'. PROJECTED LIGHTING AREA IS APPROXIMATELY 28,320 SQ FT. 2 POLES, 4 TOTAL FIXTURES, EACH @ 426 WATTS PER LUMINAIRE. (2) 277V LIGHTING CKTS (1 FOR THE POLES, 1 FOR PHOTOCELL) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23266	19041-20000-14522	1132 W 51ST PL	90037	9	108B197    54	5002029008	R2-1	South Los Angeles	South Los Angeles	Voices		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	33.99587	-118.29488	PLAN CHECK FOR INSTALLATION OF A PV SYSTEM WITH ESS ON EXISTING SFD. SYSTEM SIZE IS 6.08KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (19) PV MODULES WITH SOLAR EDGE P320 POWER OPTIMIZERS, A SE7600 INVERTER WITH A 5KW AUTO TRANSFORMER, 125A ESSENTIAL LOAD CENTER, AND (2) 9.8KWH TESLA POWERWALL BATTERIES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23267	13041-20000-32720	18758 W WELBY WAY	91335	3	180B121   108	2126036013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.19277	-118.54245	PV1 MICROINVERTER PLAN. TOTAL SYSTEM SIZE IS 6.5KW. 26 PANELS AND MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23268	13041-20000-17794	6800 N BALBOA BLVD Unit A	91406	6	183B133   942	2225023019	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	34.19433	-118.50092	Plan check for energy only. Addition of new lightnig load to an existing Subway Restaurant. Store # 1604. Unit A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23269	19041-20000-34472	10985 W BLUFFSIDE DR	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	09/14/2021 12:00:00 AM	ADDRESS	34.14183	-118.36949	PV2 BUILDING #5 (N) 17.5 KW AC/19.44 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (54) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23270	19041-20000-47859	20741 W TULSA ST	91311	12	210B109   315	2706025032	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.26827	-118.58568	PV1. INSTALL 13.86 KW DC PV SYSTEM WITH (42) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23271	15041-20000-12977	1880 CENTURY PARK EAST #1402	90067	5	132B161     8	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	PIN	34.06194805	-118.41416758	Plan check for Title 24 only T.I. high rise building Unit#1402. Total area: 2,663 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23272	13041-10000-09267	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM			Verifications in Progress	12/30/2014 12:00:00 AM	ADDRESS	33.79173	-118.23549	original plan check withdrawn made under application # 09041-10000-24409. new application has been generated for resubmittal. per applicant's request, plans will be resubmitted and new application has been generated for plan check.TI - North Area Control - this project is located at a refinery but applicant states not in a classified location.  Permit is for new UPS system, new MCCs, XFMR, associated equipment and ckts.  Project is also for reallocation of existing panels to new panel PPM-UPS-69. P/C is for Power only.  (By Inspector Packard's Request ==> Application Withdrawn 1/29/13)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23273	18041-20000-30110	5455 W HOLLYWOOD BLVD	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.10193	-118.30881	Installation of 800A distribution for 8 EV Chargers at 480V 3ph-4w in underground parking structure in commercial building.COMPLY WITH DEPARTMENT ORDER effective date08/28/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23274	14041-20000-29017	12320 W MIRANDA ST	91607	2	174B165   441	2340021017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.1743	-118.40153	Roof mounted PV system with total size 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23275	13041-10000-18038	23047 W CUMORAH CREST DR	91364	3	168B097   658	2074034017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.15411	-118.62929	PV1.  Install 5.50 kW roof-mounted solar array, interconnect into main service panel.  {22 modules: Trina Solar TSM-250PA05.08} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23276	18041-10000-26447	206 E 8TH ST	90014	14	127-5A211 318	5145013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.04154	-118.25223	PLANCHECK FOR T24 ENERGY NOT REQUIRED PER ENERGY CODE EXCEPTION 1 TO SECTION 141.0(b)2K. TENANT IMPROVEMENT FOR RESTAURANT. 856 SQFT.BUILDING PERMIT # 18016-10000-16209	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23277	19041-20001-33873	10419 W MYRNA ST	91601	2	174B177   931	2417011011	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.16963	-118.35752	10-07-2019 Changes to an approved set of plan, Changes include update filed condition main breaker 200A. Changes has been cluded. Plan check only, permit covered under master application.  Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23278	18041-20000-25223	6313 W RIGGS PL	90045	11	102B165    89	4110013014	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	33.9779	-118.39671	Plan check for a PV1 roof-mounted PV system. System size is 13.76 kWdc/12.44 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (41) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23279	18041-10000-06155	10250 W SANTA MONICA BLVD 2940	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check  for first time tenant ""Anthropologie""  Ste.#2940 in Westfiled century City. Install (4) new panels, (1) 225kVA transformers, new lightings and powers. Total area: 19,193 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23280	16041-20001-02627	8926 W RIDERWOOD DR	91040	7	207B189   373	2547028023	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.26541	-118.32644	expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 7.5kW with 30 modules and 30 microinverters. Home owner builder submitting the plan}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23281	13041-10001-10048	5115 W WILSHIRE BLVD UNIT G	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.06233	-118.34134	CHANGES TO APPROVED SET OF PLANS. DELTA 2 CHANGES ONLY. PLAN CHECK FOR T24 ENERGY ONLY.THE PC # IS VALID FOR BOTH PLAN CHECK AND PERMIT.PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT COFFEE BEAN. 2007 SQR FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23282	16041-10000-41783	22215 W MAYALL ST	91311	12	204B101   405	2745011040	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.25418	-118.61127	PV INSTALL NEW 5.232 KW DC/AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(16) AC MODULES: SPR-X22-360-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23283	10041-20001-05398	8314 W 3RD ST	90048	5	138B173   892	5511031036	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.07259	-118.37057	PLAN CHECK T-24 ENERGY FOR RETAIL/COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23284	15041-20000-30499	20205 W HEMMINGWAY ST	91306	3	189B113  1366	2107011084	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.21412	-118.57323	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (30) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23285	19041-20000-12022	777 S FIGUEROA ST 43rd Floor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only. Project site is the 43rd floor restrooms of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 750 sq. ft.Note: Building application has been generated under 19016-10000-08435	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23286	13041-10000-17475	1680 N VINE ST 103	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	permit to be pulled at EPC counter. pc for energy only. TI TO (E) RETAIL to optometry office (not medical PER APPLICANT). hirise. TENANT IMPROVEMENT IN (E) RETAIL IN UNIT #103	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23287	18041-10000-33643	10921 W WILSHIRE BLVD #411	90024	5	132B153   344	4363023032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.05881	-118.44477	PC FOR TI TO (E) MEDICAL OFFICE IN A HIGH RISE. SCOPE INCLUDES NEW LIGHTS AND CIRCUITS.  TOTAL AFFECTED AREA 1582 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23288	14041-20000-29572	6543 N KENWATER AVE	91307	12	180B089   535	2033009011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.18936	-118.6441	PV1Install roof-mounted solar array on SFD, interconnect with 200A MSP. 1 string of (14) EnPhase M250 microinverters with (14) Solar World SW275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23289	11041-10000-18110	11659 W SANTA MONICA BLVD	90025	11	126B149   212	4262002015	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.04421	-118.45548	change of switch gear from outdoor to indoor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23290	14041-10000-17126	1930 E 15TH ST	90021	14	120A215   173	5167019023	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.02261	-118.23619	"PLAN CHECK FOR NEW 1200AMP SWITCHBOARD REPLACING AND EXISTING 1000 A SWITCHBOARD, 1 PANEL AND 1 TRANSFORMER. PANEL ""A"" LOADS ARE EXISTING. NO UNDERGROUND WORK OR PENETRATIONS OF METHANE MEMBRANE IS IN SCOPE OF WORK. METHANE BUFFER ZONE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23291	13041-10001-29209	964 S BERENDO ST	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	34.05378	-118.29358	CHANGES TO PERMITTED SET O FPLANS-NEW PANELBOARDS,CKTS, AND LUMINAIRES((((((FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY BAPTIST CHURCH AND PRIVATE SCHOOL OVER ONE LEVEL OF SUBTER. PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23292	14041-20000-24740	4901 N WOODMAN AVE	91423	4	168B157   227	2269023010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM			Corrections Issued	09/10/2014 12:00:00 AM	ADDRESS	34.15955	-118.43158	New Roof Mounted 3850W PV System.Plan check is not needed customer took a permit and will ignore plan check	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23293	17041-10000-18493	160 S VIRGIL AVE	90004	13	138A201   238	5501017044	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.07167	-118.28658	TI-24, REMODEL OF THE SOUTH LOBBY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4068.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23294	16041-10000-01647	2029 S CENTURY PARK EAST STE N 1060	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, TENANT IMPROVEMENT TO (E) OFFICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT.  4615 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23295	19041-20001-23246	5130 E ALMADEN DR	90042	14	157-5A225 350	5479026006	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.1242	-118.20281	Revision to approved set.  Change of module type to 315 W SC315B2.  Associated system rating change to 5.985 kW DC.  $0 permit and plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414. (((Plan check for PV and Energy Storage System, PV system size: 5.795KW, Energy storage system size: 27KWh, with 19 PV modules and 1 inverter(5.2KW) and 2 Tesla Power Wall 2.0.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23296	13041-10002-26010	12855 W RUNWAY ROAD BLOCK 1	90094	11	102B157   395	4211033036	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	33.97556	-118.41956	REVISIONS TO PERMITTED SET OF PLANS:ADDED NOTE FOR THE CONDUCTORS FROM THE ATS TO THE FIRE PUMP;REMOVED SUBPANELS FROM SWBD3.2H; SUPPLY PANEL 3.1P1A FROM THAT SWBD. RECALCULATED LOADS FOR SWBD(((((((PLAN CHECK FOR POWER AND ENERGY. THIS IS BLOCK 1 OF PLAYA VISTA PROJECT. ELECTRICAL INSTALLATION FOR MULTI-FAMILY 4-STORY OVER PODIUM; 3 SERVICES (SERVICE 1,2,3), LOCATED IN METHAN ZONE, LEVEL-5.  2 GENERATORS INSTALLED. TOTAL 309 UNITS. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM FROM PLAN HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23297	12041-10001-30516	6600 N TOPANGA CANYON BLVD #1082D	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Expired	07/15/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR REVISION TO APPROVED PLANS. CHANGES TO LIGHTING, T24 ENERGY, AND ADDITIONAL CIRCUITS INSTALLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23298	15041-20001-16800	6256 N TOPANGA CANYON BLVD C-1340	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	08/21/2015 Changes to an approved set of plans. Changes include the additon of required lighting controls to the bathroom and the sales floor. *****Previous Work Description*****TI to existing commercial building (T-mobile). First time tenant. Plan check for power and energy. Adding new lighting includng emergency. Total sqft. 2834	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23299	14041-10000-17812	1940 S LONG BEACH AVE EAST	90058	9	118-5A213 352	5167013039	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM			Reviewed by Supervisor	09/16/2014 12:00:00 AM	ADDRESS	34.01935	-118.24271	PV2 92.95KWdc. 480V. xmfrLESS/Ungnd. NONstd. ???story. Roofmount. [(3) inverters: {POWERONE TRIO-27.6,27.6,27.6}]. [(338)modules: {solarworld SunModule SW-275 mono}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23300	17041-20000-02005	21700 W OXNARD ST Suite 900	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Issued	01/20/2017 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for Title 24 only. Project site is a suite on the 9th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,662 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23301	17041-10004-36915	742 N ORANGE DR	90038	5	141B181   378	5524014004	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.08467	-118.34147	DELTA 4 Changes to an approved set.  Relocating ESS's (Tesla Powerwall), load centers and disconnects location. PC ONLY (((PC FOR CHANGES TO APPROVED SET.SCOPE INCLUDES TWO ADDITINOAL  ESS'S (TESLA POWERWALL 2 )WITH NEW PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23302	18041-20002-21223	2222 N MARAVILLA DR	90068	4	150B181   103	5549013025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.11034	-118.34337	11-28-2018 Changes to an approved set of plan, changes include addtion of 2 PV modules, total of PV modules 23 and update PV System size: 7.475kW. Previous plan check approve 27KWh Enery Storage System	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23303	17041-10001-46409	10870 W VICENZA WAY	90077	5	147B145   173	4369039025	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2017 12:00:00 AM			PC Approved	01/27/2021 12:00:00 AM	ADDRESS	34.09718	-118.45899	Supplemental for expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23304	19041-20000-46732	14564 W DEERVALE PL	91403	4	162B149   372	2275031009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.13986	-118.45213	Plan check for PV roof mounted system, PV system size: 11.4KW AC, 15.6KW DC with 48 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23305	17041-20001-00660	3939 N LONGRIDGE AVE	91423	4	162B157   399	2385006008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.14162	-118.42054	expedite per applicant.pv1install roof mounted pv system sized 15kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23306	15041-10000-18176	2525 W WILSHIRE BLVD	90057	1	133-5A201  95	5141006017	C4-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Apartment			06/11/2015 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	12/22/2020 12:00:00 AM	ADDRESS	34.06059	-118.28114	New methane gas detection system in subterranean parking garage of new 7-story mixed-use building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23307	13041-10000-36301	616 W 97TH ST	90044	8	093A201   267	6054026014	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	33.94815	-118.28505	PV1, Install 2.75 kW DC roof-mounted solar array for a  house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (11) Modules: Trina Solar TSM-250PA05.18.(11) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23308	14041-20001-34792	6629 N LEMP AVE 1-3	91606	2	180B169   464	2320025016	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Apartment			12/16/2014 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.1912	-118.38487	EXPEDITED PER CUSTOMER REQUEST.PV2. INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (14) SUNPOWER SPR-327NE MODULUES (1) POWERONE PVI-4.2TL INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23309	19041-10000-29882	601 S FIGUEROA ST 15TH FL	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	T. I. FOR FULL 15TH FLOOR. INSTALLING NEW LIGHTS, 75KVA TRANSFORMER, PANELS AND LOADS. AREA: 17,902 SQR FT.BUILDING PERMIT: 19016-10000-23725	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23310	16041-10000-38728	5326 E YORK BLVD	90042	14	156A227   462	5478004023	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.1198	-118.19937	Plan check for power and TItle 24.  Service upgrade in existing office building to 600 amps at 120/208 volts.  4 new subpanels with associated lighting, receptacles, and HVAC.  Total area = 2,043 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23311	19041-20000-47362	5348 N TOPANGA CANYON BLVD #204	91364	3	171B101   328	2169003051	C2-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	34.16733	-118.60556	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS, PARTIAL PERMITS PAID UNDER 19041-20000-40626. TOTAL AFFECTED AREA IS 516 SQFT. (B#19016-20000-15408)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23312	17041-10000-31054	2121 S AVENUE OF THE STARS 34th floor	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	PC for TI 24 only for office TI on 34th floor. PC for new lights. Installing new lights, circuits, receptacles, one 112.4KVA transformer, one 80KVA UPS and 400A UPS panel. Total area of 10893sqft. Installed load under 400A. Building# 17016-10000-24613.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23313	13041-10000-14125	2515 S BROADWAY	90007	9	121-5A205 199	5126036011	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.026	-118.26958	PV2 134.4KW DC. transfomer isolated. SOLECTRIA PVI60KW INVERTERS (2) AND (480) MODULES ET SOLar et-p672280. roof mount. nonstandard plan. check if appoved by building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23314	14041-20002-07790	14053 N SADDLE RIDGE ROAD	91342	7	228B141    24	2582033043	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.32559	-118.48252	Modifications to approved set.  Increase of inverter output circuit EGC wire gauge.  (((Roof mounted PV system with Optimizers and transformerless inverter.  System size 3.8KW.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23315	14041-20000-03322	1111 W WILSHIRE BLVD SUITE 101	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.05259	-118.26348	First time tenant on first floor, suite #101.  Plan check for power and energy.Note: The engineer will submit the core & shell approved plans in about 4 days from submittal date.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23316	15041-10000-32123	1999 S AVENUE OF THE STARS 17th fl.	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	T-24 only on office area on the 17th fl. Ste. 2580, Total area: 3301  sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23317	14041-20000-03562	17545 W ROSCOE BLVD	91325	12	192B129   285	2787016005	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.22118	-118.51658	$0 permit fee is due to the 2012 Senate Bill No. 1222PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.3 KW AC USING ENPHASE MICROINVERTER M215. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23318	14041-10000-32917	1913 W BAXTER ST	90039	13	144A211    10	5420008021	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.09076	-118.25287	Installation of new roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23319	17041-20000-11357	20534 W VALERIO ST	91306	3	186B109   745	2113020008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Issued	04/07/2017 12:00:00 AM	ADDRESS	34.20458	-118.58098	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD ACM PLAN. SYSTEM SIZE: 5.7 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23320	15041-10000-35556	403 W ADAMS BLVD	90007	9	121-5A205 317	5126017018	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.02746	-118.27394	REPLACING FIRE ALARM PANEL AND CONNECTING NEW DEVI CES FOR THE BASEMENT LEVEL. ALL DEVICES ON THE 1ST, 2ND AND ROOF FLOORS ARE EXISTING TO REMAIN . BUILDING IS AN ORTHOPAEDIC INSTITUE FOR CHILDREN. 80 FA DEVICES, ONE CONTROL PANEL,  ONE FA PANEL AND 2 ANNUNCIATOR PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23321	16041-10000-16015	151 E 47TH ST	90011	9	112-5A205 299	5109002045	R2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.0012	-118.27277	PV1. NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. SCOPE INCLUDES 16 MODULES(SOLAR WORLD SW260) AND 16 MICRO-INVERTERS (ENPHASE M215-60). TOTAL SYSTEM SIZE IS 3.4KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23322	17041-20000-39694	5959 N TOPANGA CANYON BLVD	91367	3	177B101   228	2146006012	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.17827	-118.60529	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for solar pv system w/roof-mounted array on commercial building.Total system size: 168kW ungrounded.(7) 24kW Fronius inverters.(623) 310W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23323	19041-20000-17490	747 E 59TH ST	90001	9	105B205    17	6007002028	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Issued	05/09/2019 12:00:00 AM	ADDRESS	33.9873	-118.26122	New outlets and lighting fixtures in (E) warehouse building.  EM egress lighting existing to remain per applicant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23324	14041-10000-01087	1130 S LOS ANGELES ST	90015	14	126A209   299	5145021004	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.03749	-118.25764	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE DONE INDOORS. 1626 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23325	19041-10000-45990	3310 N VERDUGO ROAD	90065	1	153A215   332	5456001038	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	08/20/2020 12:00:00 AM	ADDRESS	34.11195	-118.23579	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 48  (CSUN 275-60P)  MODULES, 48  (ENPHASE IQ6-60-2-US) MICROINVERTERS,  CONNECTED TO AN EXISTING 400A MAIN SERVICE PANEL. SYSTEM SIZE IS 13.20KW DC & 11.04KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23326	19041-10000-08146	1925 S TUDOR LANE	90034	10	126B173  3095	6207036031	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.04074	-118.37113	ADD A NEW 13.5 KWH TESLA POWER WALL STORAGE BATTERY TO THE EXISTING PV SYSTEM SINGLE FAMILY DWELING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23327	16041-10000-39894	1601 E OLYMPIC BLVD # 109	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.02923	-118.24056	Replace HiD fixtures with new LED fixtures. Total (OUTDOOR)sqft = 12700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23328	18041-10001-26896	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	09/29/2021 12:00:00 AM	ADDRESS	34.04342	-118.25478	Change to approved set by modifing the single line and floor plan, new load also being added. all changes under delta-(13-16) only.(((3 STORY TI; CHANGE OF USE FROM RETAIL TO CAFE & RETAIL. PLAN CHECK FOR POWER AND ENERGY. AREA: 10,212 SQR FT.BUILDING PERMIT: 18016-10000-22936)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23329	13041-10000-01022	1510 S GRIFFITH AVE	90021	9	121-5A211 119	5132025017	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.02819	-118.25136	verification: added new panel AC 200a 240v 3p3w for future ac units for a total of 3 panels (service, pnl p, pnl AC)Changing out 2 panel boards for new ones. New 600A service and 100A panel. All branch circuits are existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23330	19041-20001-46677	12010 N LOUISE AVE	91344	12	216B129   137	2606028027	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			PC Approved	01/15/2020 12:00:00 AM	ADDRESS	34.28989	-118.51262	Expedite per applicant requestPlan check for PV roof mounted system, PV system size: 13.6KW DC, 11.87KW AC with 34 AC Modules connected to existing 400A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23331	18041-30000-09220	13471 W BEACH AVE	90292	11	108B149  1140	4230003071	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	33.99043	-118.44621	Plan check for Title 24 only in existing space T.I. office space. Total area: 5,458 sq ft. #B 17016-30000-32146Note: Part of the plan is belong to Culver City and part of the plan is Part of City of Los Angeles. Requirements for Title 24 shall comply with both jurisdictions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23332	18041-10000-31234	5538 N FULTON AVE	91401	4	174B157   682	2345001023	[Q]C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.17133	-118.42233	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23333	16041-20001-36729	10611 W STALLION RANCH ROAD	91040	7	204B177   264	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM			PC Approved	10/24/2016 12:00:00 AM	ADDRESS	34.25746	-118.36078	expedite per applicant.pv1install roof mounted pv system sized 15kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23334	13041-10000-27881	888 W SUMMERLAND AVE	90731	15	018B197   201	7447015007	R2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Expired	11/12/2015 12:00:00 AM	ADDRESS	33.74773	-118.29633	PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 3.75/ 2 STORY HOUSE. TRANSFORMERLESS UNGROUNDED.(15) TRINA SOLAR # TSM-250PA05.18(1) POWER ONE # AURORA PVI-3.0-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23335	14041-10000-33654	6934 N REMMET AVE	91303	3	183B105   751	2138010011	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.19659	-118.60013	Installation of a PV1 roof-mounted PV system. System consists of (1) inverter and (15) modules. System size is 5 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23336	12041-20000-25852	11601 W WILSHIRE BLVD 210	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Expired	12/08/2015 12:00:00 AM	PIN	34.0509267	-118.45996763	Plan check for energy and emergency lighting. Commercial high rise. 2nd floor, suite 210. 5461 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23337	13041-10000-17382	1999 S AVENUE OF THE STARS 20thfloor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/02/2013 12:00:00 AM	ADDRESS	34.05886	-118.41642	permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. 20TH FLOOR TI TO EXISTING OFFICE. emergency lights with generator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23338	12041-10002-24201	4225 S CENTRAL AVE	90011	9	114A209   153	5115019033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.00695	-118.25669	((( CHANGES MADE TO APPROVED SET OF PLANS. )))NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING FOR A BUILDING CHANGED FROM A HOTEL TO  APARTMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23339	18041-10000-41642	5010 S BROADWAY	90037	9	111A203   335	5110023031	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.99697	-118.27811	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23340	13041-10000-09032	621 S WESTERN AVE SPACE #G01	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	CHANGE OF USE FROM RETAIL TO RETAIL AND TAKE-OUT RESTAURANT.    TENANT IMPROVEMENT   1,150 SF RESTAURANT AND  400 SF RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23341	14041-10000-19675	5507 W HOLLYWOOD BLVD	90028	13	148-5A193 129	5544005029	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.10192	-118.30983	FA FOR MARSHALL'S. 5507-B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23342	18041-20000-43702	700 S FLOWER ST 4th flr	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	ti to an exisitng commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23343	18041-20001-42220	8545 N HATILLO AVE	91306	3	192B113    95	2782016011	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.22574	-118.56523	Expedite per applicant request install roof mounted pv system sized 16.258KW with Energy storage system size: 27kWh with 50 PV Modules and 2 inverters(10.0kW and 3.8kW), 2 Tesla PowerWall 2.0 13.5kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23344	15041-10001-24065	1500 W PACIFIC COAST HWY Bldg F2	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION of 6 devices for future ADA requirement.(((NEW FA SYSTEM FOR A New 2-story, 2 unit apartment with garage, . 9 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23345	19041-10000-41520	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2342.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Issued	12/24/2019 12:00:00 AM	ADDRESS	34.02198	-118.33376	PLAN CHECK FOR POWER ONLY. TEMP POWER(6 MONTHS OPPERATION ONLY PER FIRE DEP. ID:F19-01803) USING 570KW GENERATOR FOR HVAC EQUIPMENT ONLY - ALL LOADS HAVE BEEN APPROVED AND CONNECTION TO SERVICE ARE UNDER PERMIT 19041-20000-13132.ALL EQUIPMENT SHALL BE FULLY RATED - NO SEIRES RATING ALLOWED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23346	16041-10000-33301	10250 W SANTA MONICA BLVD # 2880	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Seafolly"" Ste. 2880.  Install new panels and transformer, total effected area: 1,017 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23347	15041-20000-23426	10465 W ARMINTA ST	91352	2	189B177   368	2407016028	M1-1, MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.21419	-118.35948	PLANCHECK FOR ADDITION OF COOLER / FILM VAULT. 700 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23348	14041-20000-29857	15760 W VENTURA BLVD SUITE 1250	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.1552	-118.47684	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING LIGHTING USING EXISTING POWER EQUIPMENT.  WORK TO BE PERFORMED IN SUITE 1250.  6661 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23349	15041-10000-13263	15927 W VENTURA BLVD	91436	5	168B141   544	2261021007	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM			PC Approved	05/01/2015 12:00:00 AM	ADDRESS	34.15615	-118.48017	INSPECTOR TO HAVE APPLICANT SUBMIT FOR FULL PLAN CHECK FOR PLACE OF ASSEMBLYALTERATIONS IN EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24 with new lighting and receptacles. Permit is paid under original permit. # 15041-10000-02568.  note: customer did not want to have supplimental permit under original application due to alot of changes on the lighting plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23350	18041-10002-47941	2955 N PASSMORE DR	90068	4	157-5A181 308	2427009018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM			PC Info Complete	01/24/2019 12:00:00 AM	ADDRESS	34.12533	-118.35187	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY CHANGES INCLUDE CHANGE IN SYSTEM SIZE FROM 20.779 AC TO 19.82 AC, REDUCTION OF MODULES FROM 65 TO 62.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23351	14041-10000-23706	13031 W JEFFERSON BLVD Building 9	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	PLAN CHECK FOR ENERGY ONLY. LIGHTING DONE IN 2 BATHROOM STALLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23352	16041-10000-41235	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	33.97954	-118.42015	PC FOR ENERGY AND POWER. T.I OFFICE IN AN EXISTING ONE STORY BUILDING. DELETING FEEDERS AND ADDITION OF NEW ONES. INTERCEPTING NEW AIR CONDITIONERS TO EXISTING FEEDERS. TOTAL AREA OF LIGHTING 1 03784 SQ FT. B # 16016-10000-28032	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23353	13041-20000-36185	3743 N LANKERSHIM BLVD	90068	2	162B177   427	2378001019	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.13663	-118.36484	pv1 single family dwelling. total system size 6 kw ac using transformerless inverter nonstandard plan. 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23354	15041-20000-20162	1973 N VAN NESS AVE	90068	4	150A191     8	5587016022	R1-1-HPOZ	Central	Hollywood	Hollywood United		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM			Corrections Issued	06/26/2015 12:00:00 AM	ADDRESS	34.10731	-118.31602	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23355	19041-20000-41050	11881 W TERRA VISTA WAY #104	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23356	14041-10000-10741	8450 W 3RD ST	90048	5	138B173   801	5511032037	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.07306	-118.37487	permit to be pulled at EPC counter only. Plan check for energy only. 2 story. TI (E) bar/restaurant (Toca Madera).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23357	17041-20001-25196	515 S FIGUEROA ST ste 1235	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	08/03/2017 Changes to an approved set of plans. Changes have been made to the emergency lighting system.*****Previous Work Description*****ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23358	11041-10000-05887	6750 W SUNSET BLVD	90028	13	147A185    92	5547021001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	ADDRESS	34.09769	-118.33815	MODIFICATION TO AN EXISTING SET OF PLANS.  10041-10000-03056 ADDED ICE MACHINE, CIRCUITS, LIGHTHING<<<<<<<<NEW RESTAURANT- CHICKEN FILLET>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23359	16041-20000-16370	4713 W SATURN ST	90019	10	126B181   327	5071020008	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	PIN	34.04398803	-118.34043197	Plan check for PV roof mounted system. System size: 2.0kW with 8 modules and 8 microinverters Enphase M215. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23360	13041-20000-17480	16696 W DEMARET PL PV-1	91344	12	216B137   102	2609010005	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.29077	-118.49697	PV-1. Microinverter standard plan. 4.968kW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23361	14041-20000-00168	21820 W BURBANK BLVD 229	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.17228	-118.6032	T24 FOR NONHIGHRISE OFFICE REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23362	12041-10002-06008	3900 N STANSBURY AVE	91423	4	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1417.00	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	ADDRESS	34.14084	-118.44264	revised permitted set of plansNew 2-story private school.  Plan check for Power and Energy.  622A of load.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23363	19041-10000-39165	5710 S CRESCENT PARK EAST Roof Deck	90094	11	102B157   265	4211020221	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Issued	10/30/2019 12:00:00 AM	ADDRESS	33.9718	-118.42824	T-24, PLAN CHECK FOR ENERGY ONLT. SCOPE OF WORK INCLUDES THE REPLACEMENT OF POOL LIGHTING (COMMON AREA)TO LED FIXTURES. TOTAL SQ. FT. 2829.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23364	17041-10000-35087	404 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM			PC Info Complete	10/03/2017 12:00:00 AM	ADDRESS	34.04451	-118.25625	"PLAN CHECK FOR T24 ONLY, INTERIOR TENANT IMPROVEMENT OF A RESTAURANT ""PARIS BAQUET"" ON THE GROUND LEVEL OF AN EXISTING BUILDING, NEW CONNECTED LOAD < 400A.B#17016-10000-28577"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23365	15041-20000-33675	23164 W VENTURA BLVD	91364	3	171B097   865	2042006078	QCR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	9304.01	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.16265	-118.63037	PLAN CHECK FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23366	16041-10000-20795	208 W 77TH ST	90003	9	099B201   236	6031017015	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	33.96966	-118.27639	INSTALL NEW 3.18 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23367	15041-10000-29038	12751 W MILLENNIUM #140	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	33.9761	-118.41651	CHANGE OF USE FROM RETAIL TO RESTAURANT.  TI TO AN EXISTING COMMERCIAL BUILDING ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 4334.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23368	11041-10000-20307	7568 N LANKERSHIM BLVD	91605	2	186B169   281	2316013001	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.20822	-118.38758	T.I. to an existing 7-Eleven building.  PLAN CHECK ONLY, for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23369	18041-20000-26664	7417 N VAN NUYS BLVD	91405	6	186B149   389	2218004016	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Issued	02/05/2019 12:00:00 AM	ADDRESS	34.20537	-118.44897	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor parking lot lighting. Total lighting area = 61,649 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23370	15041-20003-37382	7900 N BALBOA BLVD BLD. LIMA	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	Changed on the floor plan (15041-20000-37382), adding 5 branch circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23371	19041-10000-39010	1358 W LOBBY CIR	90710	15	039B193   690	7439020103	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Issued	10/22/2019 12:00:00 AM	ADDRESS	33.79982	-118.30179	[E-Plan]  Install 1 New Energy Storage System(TESLA POWERWALL) @13.5kWH & 1 New 200A Load Center with relocated loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23372	17041-10002-16328	9029 N DE SOTO AVE	91304	3	195B109    20	2779001035	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.23441	-118.58877	change to approved set by expanding the floor plan, and upgrade the service. All change under delta-2 only.Portion of the permit fee is paid under  #17041-10000-16328 and #17041-10001-16328	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23373	18041-10001-04678	13755 W BAYLISS ROAD	90049	11	138B133    22	4492015016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.07848	-118.50687	Supplemental for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23374	19041-20000-36656	10350 N NEWHOME AVE	91040	7	204B189   305	2560002023	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.2574	-118.32089	PLAN CHECK FOR NEW ROOF PV SYSTEM AND ENERGY STORAGE SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 7.56 KW DC/ 7.6KW AC. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER, (2) SUBPANELS, AND A 13.5KWH BATTERY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23375	11041-20000-01612	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	05/14/2021 12:00:00 AM	ADDRESS	34.03145	-118.41085	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23376	16041-30000-36054	3608 S CLARINGTON AVE	90034	5	120B165   450	4313007027	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.02665	-118.40334	Title 24 plan check.  Change of use from residential to child care facility.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23377	19041-10000-53831	13200 S ESTRELLA AVE STE B	90248	15	081B201   340	6132003033	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.91286	-118.28606	REMOVE HID FICTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY. INDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23378	13041-10001-32267	14016 W ROSCOE BLVD	91402	6	192B153   799	2213001017	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			Reviewed by Supervisor	11/26/2013 12:00:00 AM	ADDRESS	34.22147	-118.43831	Expedited RSES plan check per applicant request.(((PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 16 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23379	19041-10000-42181	1421 S MAIN ST STE-B	90015	14	124-5A207 268	5133008004	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.03457	-118.26207	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23380	17041-10000-25603	20541 W KINGSBURY ST	91311	12	207B109   398	2707009028	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.26372	-118.58114	PV1, New roof mounted solar system using AC modules. (20) AC modules total system size, 6540W.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23381	11041-10000-20759	400 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	1st time tennant for Terminal 4 / Space 4A at LAX.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23382	12041-20000-05003	6171 W BARROWS DR	90048	5	132B177   191	5088017027	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2012 12:00:00 AM			Reviewed by Supervisor	03/06/2013 12:00:00 AM	ADDRESS	34.06047	-118.36532	Photovoltaic system using enphase M215 inveters on roof of single faimly dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23383	18041-10000-48896	7463 N MASON AVE	91306	3	186B109   467	2113002011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Issued	01/11/2019 12:00:00 AM	ADDRESS	34.20648	-118.57991	Permit fee is $0.00 due to AB1414New rooftop solar system on SFD, 11.4 kW AC / 12.3 kW DC (STC). (41) modules, (41) P320 optimizers, (1) 11.4kW central inverter, system interconnect at 200A rated MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23384	17041-10000-10526	1230 E ADAMS BLVD	90011	9	118-5A211 431	5119021023	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.01701	-118.25167	PC  for for emergency voice evacuation fire alarm for a school.  Total device count - 85	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23385	11041-10000-17314	2619 W WILSHIRE BLVD	90057	1	133-5A201  70	5141009015	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Public Safety Only			08/16/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	11/09/2011 12:00:00 AM	ADDRESS	34.06097	-118.28196	replacing fire alarm panel and some fa devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23386	16041-20000-14702	19148 W NAPA ST	91324	12	192B121    76	2784006030	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.2263	-118.55074	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (31) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23387	19041-20000-41386	11825 W TERRA VISTA WAY #134	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23388	14041-10007-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			09/10/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Closed	05/20/2020 12:00:00 AM	ADDRESS	33.95637	-118.3838	09-10-2018 Changes to an approved set of plan, Changes include revised emergency lights to feed from EM Light Inverter, add heat recovery box, add 3 condensing unit. All changes has been clouded as delta 12.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23389	10041-10000-14818	3207 S UNIVERSITY AVE Bldg A-Church	90007	8	121-5A201   6	5123008016	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	ADDRESS	34.02484	-118.2831	New 2 Story Church with community building. Building section has determined that both structures are one building as they are connected by a covered walkway on the 2nd floor.  Variance submitted to separate the Fire Alarm System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23390	13041-10000-32770	11755 W WILSHIRE BLVD 8fl-9fl	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	34.04869377	-118.46238681	pc for energy only. permit to be pulled at EPC counter. 2 SETS OF RESTROOMS (M/F) FOR 8TH AND 9TH FLOOR. less than 400A. no emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23391	19041-10000-37553	10250 W SANTA MONICA BLVD 1665	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	T.I. in an EXISTING retail space in Suite #1665. Replacing existing lights with new lights. T-24 Energy Only.Building Permit# 19016-10000-29905	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23392	19041-10000-47067	384 WORLD WAY SPACE M63	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			Verifications in Progress	03/10/2020 12:00:00 AM	ADDRESS	33.94339	-118.40887	FULL PLAN CHECK FOR A FIRST TIME TENANT IN LAX. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE LOADS. TOTAL SQ FT 3856.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23393	18041-20000-12893	20422 W BLYTHE ST	91306	3	189B113   631	2107024058	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM			Not Ready to Issue	04/10/2018 12:00:00 AM	ADDRESS	34.21463	-118.57757	PC for 6kW(ac)/6kW(dc) PV rooftop solar for SFD. Installing 20 modules with optimizers and central inverter. PERMIT FEES HAVE BEEN PAID UNDER ONLINE EXPRESS PERMIT 18041-90000-00932	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23394	16041-30000-31161	8520 W WHITWORTH DR 1-7	90035	5	132B173   706	4332029001	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.05694	-118.37685	Plan check for new fire alarm system in 4 story 7 units. Total fire alarm devices: 65 and 1FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23395	13041-10001-27896	16731 W DEVONSHIRE ST	91344	12	204B137   263	2684004010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.25765	-118.49696	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 7.5 kW. STANDARD PLAN.  1 STORY HOUSE.(30) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23396	17041-10000-23250	3950 W OLYMPIC BLVD	90019	10	129B189    85	5081010033	C2-1-O	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.05345	-118.32027	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23397	16041-10000-44945	3549 W CASITAS AVE LOT 10	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.1209	-118.25689	Plan check for Power 11 buildings SFD live work  3 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 10 of 11Note: Master Application Lot 10 type A1,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23398	18041-10002-24198	6360 W 80TH PL	90045	11	099B165   714	4108026034	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	33.96605	-118.39833	"PC FOR DC COUPLED ESS IN A SFD. PART OF A PV PROJECT UNDER MASTER APPLICATION. SCOPE INCLUDES ""LG"" DC COUPLED ESS, AUTO TRANSFORMER AND PANEL."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23399	13041-10000-16078	6101 W CENTURY BLVD	90045	11	090B169     4	4124030036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM			Corrections Issued	06/21/2013 12:00:00 AM	ADDRESS	33.9457	-118.39149	Removing existing fixtures and installing new lighting in atrium and conference room in hotel on existing branch circuits.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23400	18041-10000-15506	1111 W 7TH ST	90017	1	130-5A207 186	5143021001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM			Verifications in Progress	01/17/2019 12:00:00 AM	ADDRESS	34.05114	-118.26451	PC FOR POWER AND ENERGY FOR NEW 7 STORY HOTEL WITH TWO SUBTERRANIAN GARAGES. SCOPE INCLUDES 123 UNITS AND 3000A SERVICE 120/208  . TOTAL AFFECTED AREA IS 92351 SQ.FT. FIRE ALARM VARIENCE HAVE BEEN FILED.B# 16010-10000-06039	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23401	16041-10000-17283	12180 W MILLENNIUM	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	33.97975	-118.40731	PC FOR POWER AND ENERGY. TI AND CHANGE OF USE FROM OFFICE TO RESTAURANT INCLUDING INSTALLATION OF HOOD AND 112 KVA TRANSFORMER. OCCUPANCY LOAD PER APPLICANT IS OVER 100. TOTAL AREA 3180 SQ FT.B# 16016-10000-11163	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23402	11041-20000-12498	2924 N LAS ALTURAS ST	90068	4	156A181   572	2428013004	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2011 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.12084	-118.34862	Plan check for 15.12KW roof mounted photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23403	16041-10000-22635	6801 S PARK TER #250	90045	11	102B165   987	4104001053	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Issued	07/28/2016 12:00:00 AM	ADDRESS	33.97698	-118.39328	Full plan check. TI medical office space remodel for unit #250. Adding new lighting and power. Total connected load is greateer than 400 amps. Scope of work only includes general care (non invasive procedures) for examination rooms. Total sqft : 6153	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23404	17041-10000-17893	5811 N BUFFALO AVE	91401	2	174B157   160	2343005001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2017 12:00:00 AM	05/30/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.17612	-118.4303	PC for a PV1 roof mounted solar system. New Central inverter rated at 6.0 KW. Total of 24 solar modules and power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23405	15041-10000-16482	500 WORLD WAY TER5 LEV2	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	12/12/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	ALTERATIONS IN STORAGE AREA AND OFFICES OF COMPASS AIRLINES IN TER5 LEV2 AT LAXPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23406	13041-20000-21304	350 S FIGUEROA ST FLR 1	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.05438	-118.2549	Plan check for energy and emergency lighting. Replacement of existing luminaires with new luminaires. Corridor for a private school. Hybrid High School. 1st Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23407	18041-20000-03027	3946 N ELLENITA AVE	91356	3	162B117   188	2180012003	RA-1-H	South Valley	Encino - Tarzana	Tarzana	Yes	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM			PC Info Complete	01/30/2018 12:00:00 AM	ADDRESS	34.14121	-118.55931	install one tesa powerwall 5kw to an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23408	18041-20000-28086	14320 W ADDISON ST	91423	4	168B153     4	2248007076	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.16101	-118.44503	Plan check for Title 24 only in existing lobby and GYM T.I. appartment building. Total area: 2340 sq ft. B#18016-20000-18697	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23409	11041-10000-15328	410 N HARPER AVE	90048	5	138B173    26	5514005012	R2-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			Corrections Issued	08/31/2011 12:00:00 AM	ADDRESS	34.07841	-118.36883	NEW PV SYSTEM FOR SINGLE-FAMILY RESIDENCE ON ROOF-TOP.  PLAN CHECK IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23410	11041-20002-14848	15643 W WYANDOTTE ST	91406	6	186B141   721	2206029016	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.20311	-118.47409	Changes to approved set of plans. Air-conditioners and fan-coils downsized. Air-conditioners now equipped with 25A breakers. New 300A main breaker for MS-1, MS-1 service entrance conductors are now 500kcmil Al THW insulation.Plan check power and energy for new 3-story 19 unit apartment bldg. 1000A service supplying bldg. Modification to seperate fire system has been filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23411	17041-10001-11205	3274 N NORTH KNOLL DR	90068	4	157-5A183  18	5579034035	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.12785	-118.34312	Changes to approved set.  Change from two inverters to one inverter and change to main breaker trip rating.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23412	11041-10000-15871	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Expired	11/20/2013 12:00:00 AM	ADDRESS	34.0365	-118.3687	Application is for a new 800 amp service in addition to an existing 800 amp service.  Service is supplying power to an existing warehouse.  Applicant requests the new 800 amp service as a temporary solution while DWP works on supplying a new service for the warehouse of 3000 amps.  Applicant has been told to provide a letter from DWP stating that at the moment, the 3000 amp service cannot be provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23413	12041-10000-05398	500 S VIRGIL AVE #201	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/09/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.06492	-118.28687	T.I. to an existing Medical Office, physical therapy only - no blood work or x-rays.  Changing lights, adding receptacles.  PLAN CHECK ONLY for Energy.  Suite #201 for a 4-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23414	17041-30000-10224	11210 W SARDIS AVE 1-25	90064	5	123B157  1225	4251002023	R3-1	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	Apartment			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.02959	-118.43029	Plan check for a fire alarm system for a 25-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (105) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23415	17041-20000-34833	11619 W PENDLETON ST	91352	6	195B169   348	2631017044	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.22928	-118.386	Plan check for power and energy. TI to existing commercial warehouse. New 800A 277/480V 3ph 4w service. T24 area - 15,575sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23416	13041-20001-09450	16356 W TULSA ST	91344	12	207B137    67	2680020020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.26787	-118.48869	((9/17/2013- CHANGES MADE TO APPROVED SET OF PLANS. CHANGED WIRE SIZE AND DOWNSIZED MAIN BREAKER.))PV1 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 5.39 KW. TRANSFORMERLESS. 22 MODULES AND 1 INVERTER. [INVERTER: SOLAR EDGE SE5000A-US] [PV MODULE: TRINA SOLAR TSM-245PC05/PA05.18].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23417	18041-10002-02520	2624 S KERCKHOFF AVE	90731	15	009B197   853	7465013028	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	33.72009	-118.28961	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include relocating 200A main service, AC disconnect, and inverter on the roof-layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23418	12041-10000-17702	11075 N HILLHAVEN AVE	91042	2	210B197   209	2553003012	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.20	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.27047	-118.28995	New 3.12kw rooftop mounted PV system for an existing single family residence.  System uses Enphase M215 Micro-Inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23419	14041-10000-26528	7307 N FIGUEROA ST # 201	90041	14	162A229   323	5690025007	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.13662	-118.18837	PC FOR ENERGY ONLY. NEW TRACK LIGHTING. EXISTING RETAIL SPACE. TOTAL AREA 909 SQ FT.B  #: 14016-10000-18622	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23420	12041-20000-14428	9018 N WOODMAN AVE	91331	6	195B153   179	2642031018	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.23362	-118.4389	T.I. to an existing building in dining and restroom.  Install general/emergency lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23421	12041-10000-21330	9130 N LEV AVE	91331	6	198B161   531	2628007015	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.23551	-118.41772	Plan check 4.25KW roof mounted photovoltaic system. (Transformerless Inverter)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23422	18041-20000-38186	1155 W 36TH PL	90007	8	120B197   989	5040029017	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			10/05/2018 12:00:00 AM			Reviewed by Supervisor	11/07/2018 12:00:00 AM	ADDRESS	34.02221	-118.29327	Plan check for new 5 units multi residential building. Total area: 6272 sq ft. B#17010-10000-04522	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23423	10041-20000-20793	11541 N BLUCHER ST bldg4	91344	12	213B145    79	2605002012	QC1-1VL, QP-1VL	North Valley	Granada Hills - Knollwood		YES	1092.00	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	PIN	34.27943684	-118.47043731	Permit expired (BLDG. 4).  EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23424	15041-10000-07363	3273 W CASITAS AVE	90039	13	153B209   393	5436002023	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.11638	-118.25202	PC FOR POWER AND ENERGY. CORE AND SHELL. NEW 1& 2 STORY BUILDING. NEW 800A SERVICE. SERVICE IS FEEDING EXISTING 2 STORY BUILDING. TOTAL OF 7 BUILDINGS. EXTERIOR LIGHTING. T24 INCLUDED IN CORE AND SHELL. SEPRATE PLAN CHECK IS REQUIRED FOR TENANTS UNDER TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23425	18041-20000-13976	11155 W ERWIN ST	91606	2	177B173   359	2336022019	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.18316	-118.37416	PC for 9.8kW(ac)/11.375kW(dc) rooftop solar for SFD. Installing 35 modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23426	15041-10001-18358	4217 E CAMINO REAL	90065	1	147A221    25	5465026005	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			Reviewed by Supervisor	06/22/2015 12:00:00 AM	ADDRESS	34.09887	-118.21497	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1 INSTALL 11.13 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(42) MODULES: SUNPOWER SPR327NE(1)INVERTER: SOLARDGE SE10000A-US-ZB>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23427	13041-20000-32919	141 N MARTEL AVE	90036	5	138B181   645	5512011010	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.07486	-118.35123	PV1 HIGH FREQUENCY TRANSFORMER. TOTAL SYSTEM SIZE 18KW. 54 MODULES AND 3 INVERTERS. ***ZERO FEES DUE TO 2012 SENATE BILL***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23428	15041-20000-27764	18253 W LASSEN ST	91325	12	201B125    76	2731023001	RA-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Expired	09/19/2017 12:00:00 AM	ADDRESS	34.25017	-118.53122	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (28) Kyocera KU265 Modules (1) ABB PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23429	13041-20000-25448	13154 W CROWLEY ST	91331	6	195B157   743	2627024029	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.22995	-118.41946	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING 13 MODULES. 2 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23430	14041-20000-02033	5077 N LANKERSHIM BLVD 1-130	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			01/23/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.1626	-118.37361	fire alarm apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23431	18041-20001-23226	21331 W COSTANSO ST	91364	3	171B105   167	2167002037	(Q)C1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.16689	-118.59684	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 16.6 kWac and consists of (3) inverters, (58) modules, and (2) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23432	10041-10000-24718	5290 W WASHINGTON BLVD	90016	10	126B177  1023	5063017021	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.0404	-118.35737	NEW 21.6 KW PV SYSTEM ON THE ROOF. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23433	13041-10000-32748	1500 W PACIFIC COAST HWY BLDG B	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING BTHIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23434	19041-10000-36891	611 S WESTERN AVE	90005	10	135B193   910	5503031006	C2-2	Central	Wilshire	Wilshire Center-Koreatown		2117.04	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.06305	-118.30927	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 54 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23435	14041-10000-01305	210 N AVENUE 66	90042	14	153A233    92	5493027013	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.11498	-118.1786	PV1 1.296KWAC. 240V. microinverter. NONstd. 1story. Roofmount. [(6) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(6)modules: {sun edison F260CyC}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23436	15041-10000-27902	644 N HARVARD BLVD	90004	13	141B193   670	5521006008	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.08292	-118.30448	INSTALL NEW FA SYSTEM FOR A 3-STORY 7-UNIT APARTMENT WITH 33 FA DEVICES, ONE FA PANEL AND ONE ANNUNCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23437	14041-20001-13208	3901 N EAGLE ROCK BLVD 1-16	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Apartment			08/13/2014 12:00:00 AM			PC Approved	08/13/2014 12:00:00 AM	ADDRESS	34.11925	-118.23127	Modification to approved set.  Change of feeder sizes to match site conditions and to accommodate voltage drop issues.  Original work description: CONSTRUCTION OF NEW MULTI FAMILY DWELLING. TOTAL OF 16 UNITS. PC FOR POWER AND ENERGY. THIS PC IS FOR BUILDING B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23438	18041-30000-23249	2701 W JAMES M. WOOD BLVD	90006	1	132A201   170	5077025016	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	04/17/2020 12:00:00 AM	ADDRESS	34.05606	-118.28682	Plan check for a fire alarm system located in a new 4-story 33-unit apartment building. Scope include (1) fire alarm system, (2) power supplies and (101) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23439	13041-10001-27232	11225 N LOUISE AVE	91344	12	210B133   220	2711009005	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.27457	-118.51119	"""Expedited plan check per applicant request"".PV1 8.25KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: SOLAREDGE SE3000A-US and SOLAREDGE SE5000A-US] [( 33) MOD: renesola JC250M-24/BB].""Expedited plan check per applicant request""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23440	13041-10002-04233	12223 W SANTA MONICA BLVD	90025	11	126B145   755	4263027017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.04001	-118.46529	(((changes to approved set of plans: ASBUILT. SLD: MOVED TAP FROM END OF MSB TO AHEAD OF 1400A D/C OF MSB)))New electrical system and lighting for existing convenience store. 1992 sqrft. Service upgrade with new branch circuits and panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23441	12041-10003-16921	1801 S FIGUEROA ST	90015	9	124-5A205 281	5126002008	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.03524	-118.27179	"[[[[7/10/14   changes to approved set.  addition of panel 1h along with  2 car charging station and additional floor outlets in show room.]]]](((2/14/2014 CHANGES MADE TO APPROVED SET OF PLANS. SCOPE OF WORK HAS BEEN GREATLY REDUCED. PERMIT HAS ALREADY BEEN PULLED THIS IS A PLAN CHECK ONLY APPLICATION)))PLAN CHECK FOR POWER AND ENERGY FOR NEW 1-STORY BUILDING STRUCTURE W/ MEZZ AT 1ST LEVEL. GROUND LEVEL OFFICE AND SHOW ROOM FOR MERCEDES BENZ DEALERSHIP.  BUILDING IN METHANE ZONE. NEW 3000 AMP SERVICE. 2500A FEEDER SUPPLYING BUILDINGS MERCEDES BENZ BUILDING.  THIS APPLICATION IS FOR  PORTION""B"".  PORTION ""A"" WAS SUBMITTED UNDER 12041-10000-16921."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23442	12041-10000-26385	1310 S ABBOT KINNEY BLVD	90291	11	108B145  1283	4238004015	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	33.99094	-118.46783	TI in an existing retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23443	19041-10000-29470	1400 N GLENDALE BLVD	90026	13	141A209   359	5419020033	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.20	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	34.07982	-118.25989	FULL PLAN CHECK TO STARBUCKS TI IN EXISTING KFC DRIVE THRU FAST FOOD RESTAURANT. SCOPE OF WORK INCLUDES EXISTING SERVICE, NEW PANELS, CIRCUITS AND LIGHTING. TOTAL SQ. FT. 16178	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23444	15041-10001-34769	1570 W 226TH ST	90501	15	045B193   156	7347011011	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	33.8212	-118.30609	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 5.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(18) MODULES: LG MONO-X 280-S C-B3(1) INVERTER: FRONIUS PRIMO 3.8-A 240V>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23445	14041-20002-15930	3691 N FREDONIA DR	90068	4	159B177   295	2425006003	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	34.13297	-118.36147	[[[ 10/31/2014 CHANGES TO APPROVED SET OF PLANS. RELOCATION OF THE SOLAR EQUIPMENT.]]]]]PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 3 STRINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23446	10041-10000-22100	310 W WASHINGTON BLVD BLDG #5	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 7 UNIT TOWN HOME.   (BUILDING #5)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23447	12041-10000-00599	400 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM			PC Approved	01/10/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	T. I., Food service space for Starbucks at exist. LAX Terminal #4.P/check for compliance with lighting reqmt's. of T-24 including emergency egress and exit lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23448	11041-10000-04734	1925 S CENTURY PARK EAST 7TH FLOOR	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM			PC Approved	03/17/2011 12:00:00 AM	ADDRESS	34.06066	-118.41426	T.I.  PARTIAL 7TH FLOOR AREA FOR TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23449	15041-10000-35679	1333 N SIERRA BONITA AVE	90046	4	147B177  1376	5550027012	R3-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM			PC Info Complete	02/16/2016 12:00:00 AM	ADDRESS	34.09531	-118.35409	PC for power and energy. New 6 unit apartment building, 4-floors. Service and equipment all new. Installing 600 A service. Total Area: 8000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23450	16041-20001-26973	7401 N VINELAND AVE	91352	2	186B173   783	2315019006	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Apartment			08/01/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.20501	-118.37051	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 15 kWac and consists of (60) modules, (60) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23451	16041-10000-08006	17383 W SUNSET BLVD FL 3-BLDG A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, INTERIOR TI IN THE ELEVATOR LOBBY AND CORRIDOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACELS. TOTAL SQ. FT. 1735.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23452	12041-10002-28255	923 S HARVARD BLVD	90006	10	132B193   981	5093016025	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.05508	-118.30429	][][CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGES IS REFLECT WORK DONE AT THE MAIN SERVICE. ][][ORIGINAL DESCRIPTION: PV1 12 KW DC ROOF-MOUNT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23453	11041-10000-15047	1700 E CESAR E CHAVEZ AVE	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	34.05093	-118.21753	TI TO THE OUTPATIENT  RADIOLOGY SUITE ON THE LOWER LEVEL OF THE WHITE MEMORIAL MEDICAL CENTER MOBPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23454	17041-20000-35817	14244 W GRAMMAR PL	91402	6	195B153  1178	2638017001	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.22721	-118.44337	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23455	17041-20000-04302	3322 W BEVERLY BLVD	90004	13	138A201   136	5501018001	C2-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.07304	-118.28506	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CHILDRENS DAYCARE WITHIN MULTI-FAMILY COMPLEX. 4450SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23456	12041-10000-29873	2444 N CRESTON WAY	90068	4	153A189   198	5585017016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.11419	-118.32415	PV1.  New 5.886 KW roof mounted PV system for single family residence.  18 modules, 1 interter, 1 combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23457	16041-20001-23740	20953 W OSBORNE ST	91304	3	195B109    47	2779001030	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			PC Approved	03/17/2017 12:00:00 AM	ADDRESS	34.23315	-118.59033	Changes to approved set.  Changes to lightng system, relocation of transformer from indoor to outdoor location, and other miscellaneous modifications.  Approval of clouded changes only.  (((Plan check for Power and Energy in existing building T.I. 800A Service for Youth Center. Total area: 18,668 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23458	14041-10000-08539	17111 W CEREDO PL	91344	12	219B133   685	2606005029	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.2928	-118.50602	PV1 10KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US, SOLAREDGE SE5000A-US}]. [(40)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23459	16041-20001-05740	17427 W NAPA ST	91325	12	195B129   536	2787026051	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM			Reviewed by Supervisor	03/03/2016 12:00:00 AM	ADDRESS	34.22691	-118.51387	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (39) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23460	13041-10000-18936	6900 N LAUREL CANYON BLVD	91605	6	183B165   329	2321011019	RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.04	Electrical	Electrical	Apartment			07/17/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.19603	-118.39625	FIRE ALARM SYSTEM WITH A FIRE ALARM PANEL, A SEPERATE ANNUNCIATOR AND 55 DEVICES. BUILDING IS AN APARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23461	18041-10000-44026	419 N CORONADO ST	90026	13	138A205    55	5157004005	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1958.02	Electrical	Electrical	Apartment			11/16/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07377	-118.27262	THIS IS PLAN CHECK FOR POWER ONLY AND ADDITIONAL PERMIT FOR SERVICE AND CIRCUITS THAT ARE NOT ACCOUNTED ON THREE ORIGINAL PERMITS. SCOPE INCLUDES SERVICE UPGRADE TO 600A FOR FOUR SEPERATE EXISTING RESIDENTIAL BUILDINGS WITH TOTAL 13 UNITS, (3) BUILDING HAS (4) UNITS EACH.  EACH BUILDING ELECTRICAL PERMITS WERE ISSUED UNDER: 18041-20000-15335, 18041-20000-15300. 18041-20000-15305	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23462	16041-10003-07976	17331 W PARTHENIA ST	91325	12	195B129   402	2768016005	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.2287	-118.51244	10/24/16Changes to an approved set of plans. All change are made under delta 2. Changes include removing two modules from the single line diagram and on the roof-layout. Changes to reflect what is on the field.((((((((((PV1, NEW 15.70 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(48) MODULES: SUNPOWER SPR- E20-327-C-AC(48) MICROINVERTER: SUNPOWER E20-327-C-AC-GEN 2.2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23463	19041-10000-20965	14419 W BURBANK BLVD	91401	4	174B149   851	2245010033	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.17231	-118.44709	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23464	16041-10006-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.0365	-118.3687	Changes to an approved set of plans. All changes are clouded under Delta 19. Changes include add additional receptacles on floor plans, and revising panel schedules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23465	13041-10000-26804	1303 N SHADYBROOK DR	90210	5	144B157   538	4357007016	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.09495	-118.43052	PV1.  Install 11.054 kW DC roof-mounted solar array, interconnect with main service panel.  Enphase M215 microinverters.  49 modules: LG260S1C-G3$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23466	14041-20000-24952	2953 S CLUB DR	90064	5	123B165    37	4316028002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.03713	-118.40054	PERMIT FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 16kW.(1) SunPower SPR-10002f-1 UNI(1) SunPower SPR-6001p-1(56) Sun Power SPR-E20-327 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23467	14041-20001-23769	19688 W HORACE ST	91311	12	207B117    84	2708027014	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.26704	-118.56343	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(34) KYOCERA KD 255 MODULES(2) SOLAR EDGE 3800 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23468	12041-10000-06880	13076 N GLENOAKS BLVD	91342	7	222B149    49	2505024013	C2-1, RA-1	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.30824	-118.45026	Brand new restaurant with 400A service.  Occupancy load, per applicant, is 40.  Plan check only, for Energy only, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23469	11041-10000-20563	4416 N SYLMAR AVE	91401	5	166-5A151 296	2265014017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	PIN	34.15097228	-118.44581727	"New power for a car dealership parking lot for lighting.  PLAN CHECK ONLY for Energy.NOTE THAT PERMIT FEE IS IN ""INSPECTION"" OF THE FEE PERIOD"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23470	17041-10000-38815	15421 W ROSCOE BLVD	91343	6	192B145   367	2654027013	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Issued	10/27/2017 12:00:00 AM	ADDRESS	34.22158	-118.4688	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ FT 50775.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23471	12041-10000-28473	725 S FIGUEROA ST Suite#1700	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM			PC Info Complete	11/27/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	TI IN AN EXISTING OFFICE AREA IN SUITE #1700 ON THE 17TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23472	15041-20000-19359	9126 N LANGDON AVE 1-15	91343	7	198B145   349	2656026027	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Apartment			06/19/2015 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Closed	11/16/2018 12:00:00 AM	ADDRESS	34.23653	-118.46964	Plan check for new appartment building 15 units 3 story above parking george. Total common area: 11,7787SFfire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23473	19041-10000-33979	333 S GRAND AVE 50TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	04/09/2020 12:00:00 AM	ADDRESS	34.05271	-118.25179	TI IN AN EXISTING OFFICE SPACE ON THE 50TH FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.  AFFECTED AREA: 13815 SFBULDING PERMIT: 19016-10000-23577	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23474	15041-20000-21278	6532 N NOBLE AVE	91411	6	180B145   476	2235015029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.18962	-118.46169	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW.  STANDARD CENTRAL INVERTER PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23475	17041-20000-08741	500 S MATEO ST	90013	14	127-5A217  67	5163018005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.04146	-118.23294	PLANCHECK FOR POWER AND ENERGY.  FIRST TIME TENANT - restaurant.CORE & SHELL UNDER: 17041-20000-08744	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23476	17041-20000-27568	1320 N BEVERLY GROVE PL	90210	5	147B157   580	4356021034	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.09635	-118.42605	PLAN CHECK FOR POWER ONLY FOR NEW 2 STORY TYPE VB  SFD WITH ATTACHED GARAGEELECTRICAL PERMIT FEES HAVE BEEN PAID UNDER THE BUILIDNG PERMIT#  16010-10000-01452	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23477	19041-20002-44418	15430 W GREENLEAF ST	91403	5	166-5A145  35	2283018026	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM			PC Approved	12/16/2019 12:00:00 AM	ADDRESS	34.15244	-118.4705	$0 FEE DUE TO AB141412/16/19CHANGES TO APPROVED SET CHANGES TO RELOCATION OF EQUIPMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23478	16041-20001-10318	1446 S ARMACOST AVE 1-9	90025	11	126B145  1225	4263032049	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM			PC Approved	04/12/2016 12:00:00 AM	ADDRESS	34.04284	-118.46087	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 40KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23479	16041-10000-28494	951 S WESTWOOD BLVD	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.06281	-118.44558	Full Plan check to an existing historical building. interior TI. Change of use from dental office to retail (7 eleven). Existing serice, adding new equipment as noted in the single line.  Adding new lighting and power. Total sqft = 1954Ref. B# 16016-10000-21484	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23480	17041-10000-12709	900 W WILSHIRE BLVD 24/25TH FL	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	Plan check for power and Title 24.  T.I. to 24th and 25th floor of existing commercial highrise office building.  New lighting and receptacles.  New load > 400 amps.  Total area = 28,784 sq. ft.     Building permit #17016-10000-07664	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23481	14041-20001-33422	3201 S OVERLAND AVE 1-525	90034	5	120B161     7	4254011036	R1-1, R3-1, R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			12/03/2014 12:00:00 AM			PC Approved	02/03/2015 12:00:00 AM	ADDRESS	34.02928	-118.41552	EXPEDITE PER APPLICANT REQUEST.[PV2.Install a roof-mounted solar array on a 525 unit apartment building. Interconnect with 1200A MSP.System size: 301kW (Seven 23kW inverters & Five 28kW inverters). Ungrounded system.999  310W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23482	14041-10001-33351	744 E PICO BLVD	90021	14	123A211   160	5132019042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM			PC Approved	09/10/2015 12:00:00 AM	ADDRESS	34.03202	-118.25256	DELTA 2 FIELD REVISIONS: CHANGES INCLUDE KEEPING ELEVATORS AS LOADS ON PANEL HPA; CHANGES TO LIGHTING ON EACH FLOOR; REVISED TITLE 24 FORMS; ALL CHANGES ARE BUBBLED((((REMODELING & ADDITION  TO  (E)  2-STORY RETAIL & STORAGE & OFFICE  MALL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23483	16041-20000-05603	8467 W MELROSE PL	90069	5	141B173   424	5528001055	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	34.08374	-118.37559	Plan check title 24 energy only for existing space. Total area: 1,625 sq ft.Note: Plan check only; permit pulled on Application # 16041-30000-04904	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23484	14041-10000-09424	7844 N CLEON AVE	91352	2	189B173   509	2409009003	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.21332	-118.36801	P V1 ROOF MOUNTED TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23485	17041-10000-05176	714 W OLYMPIC BLVD #803	90015	14	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Issued	02/21/2017 12:00:00 AM	ADDRESS	34.04454	-118.26341	Plan check for Title 24 only in existing space T.I. office space. Total area: 1943 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23486	19041-10000-15809	333 S WESTGATE AVE	90049	11	132B141  1050	4404035002	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Issued	05/31/2019 12:00:00 AM	ADDRESS	34.05681	-118.47163	**permit fee is in accordance with AB-1414/SB-1222**(ePlan)  Install roof mounted solar on (E) SFD, (1) 11.4 kW AC inverter , (35) modulee, (35) P400, (1) New 225A Load Center. System connect to (E) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23487	19041-10000-52937	19619 W WYANDOTTE ST	91335	3	186B117   858	2116001094	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.20296	-118.56054	PV1, NEW ROOFTOP MOUNTED SOLAR SYSTEM CONSIST OF 20 MODULES (REC290TP2) WITH 20 OPTIMZERS (SE P320) AND 1 CNETRAL INVERTER (SE3800H-US). SYSTEM SIZE IS 5.8KWDC AND 3.8 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23488	17041-20000-12620	2822 S BAGLEY AVE	90034	5	123B165    90	4301001001	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.03693	-118.39291	PV1.  Install 5.12 kW roof mounted grid tied PV system.  AC module standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23489	17041-10000-30885	10250 W SANTA MONICA BLVD #  2895	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Info Complete	09/19/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PLAN CHECK FOR FIRST TENANT IN RETAIL SPACE #2895  ""LIDS"""	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23490	13041-20001-26714	23019 W MARIANO ST	91367	3	171B097    14	2042007004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.16844	-118.6284	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 30 MODULES. 3 STRINGS/ INVERTER. NONSTANDARD PLAN. TRANSFORMERLESS INVERTER. PC REQUIRED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23491	10041-10000-11341	801 N FAIRFAX AVE	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM			Corrections Issued	06/15/2010 12:00:00 AM	ADDRESS	34.08567	-118.36172	Change of use from retail to a bank. EPC for energy and T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23492	16041-20002-06706	4151 W PROSPECT AVE BLDG G	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM			PC Approved	01/06/2017 12:00:00 AM	ADDRESS	34.10191	-118.28217	Revisions to approved set.  Slight relocations of conduit exiting substation; clarification of system detail.  Delta-2 revisions only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23493	14041-20000-12373	1541 S ORANGE GROVE AVE 1-8	90019	10	129B173  1002	5068023006	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			05/09/2014 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.04835	-118.36655	New 8 unit apartment with 4 habitable stories over 1 level of  subterranean parking garage in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23494	14041-20000-14574	2421 N SILVER LAKE BLVD	90039	13	148-5A209 287	5440002001	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.1011	-118.25811	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23495	18041-30000-07175	2029 S CENTURY PARK EAST 5th Floor-lobby	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing space elevator lobby on 5th floor. Total area: 295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23496	19041-10000-37504	1811 W RIPPLE ST	90039	13	147A213    48	5442013900	OS-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.09892	-118.24509	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23497	13041-10000-01010	2187 W RAVENSFIELD LANE	90077	5	150B141   100	4377050016	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2013 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.10849	-118.47618	INSTALL A 600 AMP SERVICE EQUIPMENT & MISC LOADS FOR A SINGLE FAMILY HOUSE. PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER A SEPERATE APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23498	18041-20000-24987	7219 W WARING AVE	90046	5	141B181   258	5525002038	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Issued	08/23/2018 12:00:00 AM	ADDRESS	34.08537	-118.34686	Plan check for a PV2 roof-mounted PV system. System size is 69.12 kWdc/62.95 kWac-CEC and consists of (3) inverters, (192) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23499	16041-10000-06876	12700 W MILLENNIUM #1	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(16) ACM SPR-X20-250-BLK-B-AC MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23500	19041-20001-05600	1608 W 252ND ST	90710	15	036B193   267	7410020046	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	33.79561	-118.30466	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12.9 kWdc/11.324 kWac-CEC and consists of (43) modules, (43) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23501	17041-10000-25462	12100 W OLYMPIC BLVD #350	90064	11	123B149   575	4259025019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.03215	-118.45396	PC for T24 for office TI. PC for new lights and receptacles. Total area 673sqft. Building 17016-20000-15302.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23502	19041-20000-40383	18451 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23503	15041-10000-28942	541 S SPRING ST ste 116	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.04657	-118.2507	TI to change of use from retail to restaurant in a high reise bldg, adding new lighting, control, panels. Newly connected load greater than 400 amps PC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23504	19041-10000-53043	8900 S SEPULVEDA BLVD	90045	11	096B165  1026	4123001031	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	04/27/2020 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	33.95574	-118.39596	FULL POWER PLAN CHECK FOR A TI. SCOPE OF WORK INCLUDES EXISTING SERVICE OF 600 AMPS, 480/277 V 3 PHASE 4 WIRE SYSTEM (EXISTING), AND 208/120V 3 PHASE 4 WIRE SYSTEM.TOTAL AFFECTED AREA: 25,469 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23505	14041-20000-35772	5000 S MAIN ST	90011	9	111A205   300	5109004053	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	PIN	33.99720157	-118.27357014	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PC FOR PV2 COMMERCIAL ROOFTOP SOLAR. 55.2KW DC USING 4 INVERTERS. LOAD CENTER AND NET METER WITH MAIN SERVICE. TRANSFORMERLESS INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23506	13041-10000-02628	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.03497	-118.45709	Provide feeders and 2 X-former for temp power for construction of new car parking facility. No new loads or new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23507	13041-20001-09682	14141 W VENTURA BLVD # 100	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/17/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	Changes to approved set of plans. Feeders to tenant panels are paralleled for 360 feet before terminating and then being run as a single set to panels.First time tenant in suite 100.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23508	19041-20000-42566	647 N BEACHWOOD DR	90004	4	141B189   407	5523022013	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	09/17/2021 12:00:00 AM	ADDRESS	34.08303	-118.32194	NEW FIRE ALARM SYSTEM IN A NEW BULDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23509	15041-20000-04321	901 S ABBOT KINNEY BLVD BLDG B	90291	11	109-5A143 374	4286012008	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	33.9927	-118.47312	TI TO OFFICE SPACE. 2 FLOORS. PC FOR T24 ENERGY ONLY. LOW ADDITIONAL LOAD. THIS APPLICATION IS PLA CHECK ONLY.  PERMIT HAS ALREADY BEEN ISSUED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23510	19041-10000-03528	1376 W 1ST ST	90732	15	018B193   986	7452010022	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	33.74345	-118.3059	plan check for a roof mounted 3.6kva pv sysgtem consisting of 15 modules with emphase iq7-60-us microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23511	18041-10000-15964	19831 W VENTURA BLVD	91364	3	174B113   355	2164012010	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Issued	05/01/2018 12:00:00 AM	ADDRESS	34.17253	-118.56498	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23512	18041-10000-42816	1888 CENTURY PARK EAST #1115	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	PIN	34.06139499	-118.41373129	Tenant improvement to existing office in Suite #1115. Installing Lights. T-24 Energy Only.Building Permit: 18016-30000-34110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23513	17041-10000-09760	3033 W 6TH ST # 107	90020	13	135B197   981	5077004034	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.06385	-118.28817	Plan Check for energy only, Title-24. Tenant Improvement and change of use from retail to coffee shop (SweeTea Bar). One New sub-panel, new circuits, lighting, and power. Added load is less than 400 Amps. Area: 420 Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23514	16041-10000-40590	11058 W CHANDLER BLVD	91601	2	171B173  1406	2350014015	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	05/10/2017 12:00:00 AM		Issued	05/10/2017 12:00:00 AM	ADDRESS	34.168	-118.37216	5 STORY MIXED USE BUILDING. PC FOR POWER AND ENERGY. INSTALL NEW 4000A SERVICE AND NEW FP SECTION. ALL DWELLING UNITS PRIVATE METERED. THIS IS TOTAL OF 225 UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23515	19041-20000-45714	10444 N AMBERWOOD LANE	91326	12	207B121   754	2728031068	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	02/29/2020 12:00:00 AM	ADDRESS	34.26088	-118.54396	PV1.  Install 12.4 kW roof mounted grid tied PV system.  (40) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23516	14041-20002-12019	12650 W SANDHILL LANE Unit 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	33.9774	-118.4142	CLOUDED CHANGES. NEW LAYOUT. NO MONITORING UNIT. RESTAMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23517	16041-20000-34078	15260 W VENTURA BLVD Suite 2250	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.15356	-118.4658	Existing commercial office remodel.  New lights and existing circuits.  Highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23518	11041-10000-25237	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			11/28/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.10686	-118.33085	Revise wiring toroof exhaust fans including provision for inverter backup power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23519	14041-10004-24238	2725 N HYPERION AVE	90027	4	151-5A205 224	5433026037	C4-1D, P-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Expired	09/24/2018 12:00:00 AM	ADDRESS	34.10747	-118.27223	CHANGES TO APPROVED SET OF PLANS. LIGHTING IS NOW BEING CONNECTED TO PANEL FED FROM EMERGENCY GENERATOR. ALL CHANGES NOTED DELTA 3 ON PLANS NEW PANEL AND 2 CIRCUITS FOR LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23520	18041-20000-07130	3531 S PURDUE AVE	90066	11	117B157   664	4249028025	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.01501	-118.42525	addition of (1) tesla power wall to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23521	18041-20000-43435	320 S AVONDALE AVE	90049	11	129B137   277	4406024011	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.05103	-118.49108	PV1.  Install 11.52 kW DC roof mounted grid tied PV system.  (32) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23522	19041-10000-32070	5114 N STERN AVE	91423	4	171B153   586	2269004002	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	34.16361	-118.4344	0$ final fees per AB1414[EPLAN] CHANGES TO APPROVED SET OF PLANS TO REMOVE SUB PANEL - CHANGES HAVE BEEN CLOUDED UNDER DELTA B Plan Check only. ORIGINAL PERMIT 19041-10000-24724	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23523	14041-20001-17202	224 E 73RD ST	90003	9	102B205  1039	6022010012	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM			PC Approved	09/05/2014 12:00:00 AM	ADDRESS	33.97369	-118.27097	SUPPLEMENTAL TO EXISTING PERMIT NUMBER 14041 20000 17202 TO DOWN SIZE THE INVERTER FROM 5.0KW TO 3.8KW.  NO ADDITIONAL WORK TO BE PERFORMED.PV1.  Install 4.3 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23524	13041-10000-30090	12622 W GILMORE ST	91606	2	180B161  1009	2325018011	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.18747	-118.40809	PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 10 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23525	14041-20003-15782	330 N WESTLAKE AVE	90026	13	136-5A207  71	5157025043	(T)(Q)RAS4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.06951	-118.26652	07/19/2017 Extensive changes throughout. All changes have been clouded and marked as Deltas 1 thru 3. Redesign of SLD - removed panels and transformers, some new panels relative to previously approved.  Some minor changes to underlying architectural design.  Extensive changes to lighting system.  Changes to mechanical HVAC equipment ratings.  Additional outdoor heaters.  *****Previous Work Description*****PLANCHECK FOR POWER AND ENERG. 200 UNIT APARTMENT. MIXED USE. 2 SERVICES OVER 3000 AMPS EACH. FEES CALCULATED PER ENGINEER. T24 FEES NOT CHARGED PROPERLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23526	14041-10001-32438	200 WORLD WAY # 236	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Change to an approved set by modifying the load and adding (4) new circuits.Note. All changes are under clouded  delta-5 only.(((PC FOR POWER AND ENERGY. TERMINAL 2 PICK UP STIX (236). TI. TOTAL AREA 745 SQ FT.PLAN CHECKER TO VERIFY THE FEES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23527	17041-10001-39935	5224 W WILSHIRE BLVD	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.06197	-118.3438	PC for power and energy for first time restuarant tenant. PC for new kitchen equipment, lights, receptacles, four panels and 75kVA transformer.  Total area is 997sqft. B# 16016-10000-08253. Permit was issued under 16041-10000-39935	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23528	15041-20002-05454	4554 N SHERMAN OAKS AVE	91403	5	168B145   983	2283023002	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM			PC Info Complete	07/09/2015 12:00:00 AM	ADDRESS	34.15345	-118.46892	06-29-15 Change to approve set of plans. Changes include lights and receptacle in each office. No changes on service location. [[[[[[Plan check for power and energy. Project site is being changed from retail to office building. Not a high-rise building. Project scope is the installation of (4) new panels and associated loads onto an existing 600-amp service, (5) AC units, and (1) elevator. Total lighting area = 7,003 sq. ft.]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23529	14041-20001-01963	13259 W TERRA BELLA ST	91331	7	204B157   618	2620019007	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.25598	-118.42186	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23530	11041-10000-17127	10800 W PICO BLVD 375	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	34.04054	-118.4272	Pe;rmit is for the remodel of suite 325.  Plan check was for T-24 lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23531	16041-10000-02669	24417 S BROAD AVE	90744	15	039B205   212	7404019025	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Closed	05/17/2017 12:00:00 AM	ADDRESS	33.80415	-118.26238	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (22) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23532	18041-10000-13085	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	PIN	33.92817449	-118.43220714	PLAN CHECK FOR POWER ONLY FOR TI FOR STRUCTURAL CANOPY AND UNDERGROUND EQUIPMENT WITH ELECTRICAL COMPONENTS (CIRCUITS AND SUMP-PUMP) LOCATED IN HAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23533	11041-10001-11428	10250 W CONSTELLATION BLVD 4th, 5th &-6th	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM			PC Info Complete	10/19/2011 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI IN AN EXISTING HI-RISE OFFICE BUILDING ON THE 4TH, 5TH & 6TH FLOORS. PLAN CHECK IS FOR POWER & ENERGY. <<<<<<<<Variance to seperate fire alarm system is required>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23534	14041-10001-08994	5311 N MOUNT HELENA AVE	90041	14	163-5A227 107	5691006015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.14329	-118.19595	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON O 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)  TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(14) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23535	19041-10000-19139	927-931 N SYCAMORE AVE	90038	4	144B181   718	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.08796	-118.34291	INSTALLATION OF EXTERIOR LIGHTING ON WAREHOUSEPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23536	19041-20000-22241	1413 S GREENFIELD AVE pv1	90025	5	129B153   153	4324014***	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.0526	-118.44489	pv1install roof mounted pv system with battery sized 7.6KW AC interconnected with msp.  (1) LG chem resu10H battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23537	15041-20000-38555	20643 W GRESHAM ST	91306	3	195B109   102	2780009003	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.23071	-118.58342	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23538	11041-10000-18320	1627 N VINE ST	90028	13	148-5A187 236	5546009904	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00, 1910.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.10052	-118.32687	NEW FIRE ALARM SYSTEM FOR NEW PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23539	15041-20000-36580	241 S FIGUEROA ST Suite 200	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM			PC Approved	10/30/2015 12:00:00 AM	ADDRESS	34.05598	-118.25392	Plan check for Title 24 only. Project site is an existing tenant space in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,656 sq. ft.Note: Building permit has been pulled under 15016-10000-20412	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23540	15041-20000-08691	17383 W SUNSET BLVD Suite A350	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.03917	-118.55529	Title 24 plan check only.  Total area = 2,134 sq. ft.T.I. to existing commercial space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23541	17041-20000-28856	8932 N WOODMAN AVE	91331	6	195B153   373	2640016027	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.23211	-118.43779	Plan check for power and energy. Project site is an existing dental office. Project scope is a tenant improvement. Total lighting area = 10,370 sq. ft.Note: Building application has been generated under 17016-20000-23488	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23542	18041-30000-38548	321 N CLIFFWOOD AVE	90049	11	132B137    41	4405018005	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	34.06181	-118.48722	Plan check for power only Single Family Dwelling with attached garage, 800A service. Plan check only, permit covered under Building Application Number 18010-30000-02599	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23543	14041-20000-20221	189 S THE GROVE DR K70	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.07125	-118.35662	Plan check for T.I  general lighting on a retail clothing store.  Customer uses Tailored method under 2013 general lighting standard.Note: Permit is under a separate application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23544	11041-20000-26860	1111 N BEACHWOOD DR	90038	13	144B189   609	5534016010	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	ADDRESS	34.09116	-118.32131	Installation of  photovoltaic system on roof  two story sound studio.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23545	13041-20000-29474	2516 W SUNSET BLVD	90026	13	141A205   298	5402014002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			Reviewed by Supervisor	11/25/2013 12:00:00 AM	ADDRESS	34.07961	-118.26967	PC FOR POWER AND ENERGY FOR NEW MULTI USE VANILLA SHELL FOR 4 TENENT SPACES. LIGHITNG AND 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23546	16041-10001-37282	5340 S ALLA ROAD	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	33.9773	-118.42567	01/13/2017 Changes to an aproved set of plans. Plan check for power only. Changes include addition of panels and transformer to existing 4,000 A switchgear{{{{{Switchboard for (E) 2-story commercial office building to be refurbished with new circuit breakers and new 4000A bussed vertical switchboard section.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23547	19041-10000-34958	220 W ANAHEIM ST 748	90744	15	030B205   421	7416033030	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	33.77973	-118.26457	ENERGY PC ONLY FOR CHANGE OF USE FROM RETAIL TO RESTAURANT/COFFEE SHOP WITH TENANT IMPROVEMENT. AREA OF SCOPE 1,440SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23548	17041-10001-05785	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.23342	-118.3809	Supplemental PC for new lights in restrooms. Changing feeder from main to  dist panel HX from (3)4#300 to (2)4#350. All changes clouded under delta 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23549	17041-20000-03594	10561 N VASSAR AVE	91311	12	207B101   147	2722011026	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Issued	02/02/2017 12:00:00 AM	ADDRESS	34.26256	-118.60557	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.5kW ungrounded system. (23) 255W pv modules. Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23550	13041-20000-26875	18252 W VINTAGE ST	91325	12	204B125   355	2731023020	RA-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.25167	-118.53129	PV1 MICROINVERTER SYSTEM TOTAL SYSTEM SIZE 8.64KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23551	14041-10000-35892	19373 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.1878	-118.5556	Plan check for a new fire alarm system in an existing commercial building. Fire alarm consists of (1) FACP, and (35) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23552	10041-30000-07953	1820 E INDUSTRIAL ST # 101	90021	14	124-5A2171372	5164021121	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM			PC Approved	04/30/2010 12:00:00 AM	ADDRESS	34.03563	-118.23389	PLAN CHECK ONLY. ELECTRICAL WIRING FOR A NEW WINE BAR. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY. LESS THAN 50 OCCUPANCY.  PERMIT UNDER #10041-10000-06931	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23553	18041-20000-14615	18575 W CALLE VISTA CIR	91326	12	213B125   158	2872019006	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.28246	-118.53768	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23554	15041-10001-38977	801 S GRAND AVE STE 425	90013	14	129A209   267	5144020***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	PIN	34.0462287	-118.26018882	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE LOCATION AND CONTROL DIAGRAM OF TIME CLOCK FOR CONTROLLED OUTLETS. PC FOR CHANGES NOTED DELTA 1 REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23555	10041-10000-09261	1459 W 190TH ST	90248	15	060B193   376	7351001017	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	33.85852	-118.30447	New public storage. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23556	16041-30000-18980	6080 W CENTER DR 6th Floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	33.97713	-118.39172	Plan check for Title 24 only. Project site is the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 840 sq. ft.Note: Building application has been created under 16016-10000-10970	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23557	14041-10000-03249	1458 S SAN PEDRO ST UNIT #135	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	T24 PART 6 ENERGY ONLY FOR 644 SQ FT COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. REPLACING TOTAL OF (3) UNITS.  ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23558	13041-10000-20160	2036 W COLORADO BLVD	90041	14	162A223   117	5686003019	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.13898	-118.21191	REMODELING BOUTIQUE STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23559	13041-10000-19557	3828 W WILSHIRE BLVD	90010	1, 10	132B193    86	5093005004	C4-2, RD1.5-1	Central, South Los Angeles	South Los Angeles, Wilshire	Pico Union, Wilshire Center - Koreatown		2126.10, 2216.02	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM			Corrections Issued 2	07/24/2013 12:00:00 AM	ADDRESS	34.06153	-118.31007	Re-roof with Class A or B material weighing less than 6 pound per sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23560	18041-10000-46748	966-974 S KENMORE AVE	90006	10	129B197    81	5078005016	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Apartment			12/10/2018 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	10/20/2020 12:00:00 AM	ADDRESS	34.05364	-118.29671	FULL PLAN CHECK FOR 6 STORY, 50 UNIT APARTMENT. SERVICE SIZE 1600A, 120/208V, 3PH, 4W. TOTAL AREA: 30,061 SQ.FT((B# 18010-10000-03412))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23561	16041-20000-18220	24417 W CLIPSTONE ST	91367	3	177B085   414	2032013043	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Expired	06/27/2018 12:00:00 AM	ADDRESS	34.17944	-118.65729	PV1.  Install 8.2 kW roof mounted PV system.  Comprehensive central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23562	17041-30000-21196	445 N FIGUEROA ST Suite 445	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	33.77439	-118.27897	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 14,942 sq. ft.Note: Building permit has been issued under 14016-10000-07374	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23563	12041-10000-01033	21155 W CALIFA ST	91367	3	177B105   104	2149002026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			Corrections Issued	03/13/2012 12:00:00 AM	ADDRESS	34.17716	-118.59277	Change of use from university to mosque. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23564	15041-20000-33100	6028 N VANTAGE AVE	91606	2	177B165   631	2333013052	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2015 12:00:00 AM			Reviewed by Supervisor	10/30/2015 12:00:00 AM	ADDRESS	34.18029	-118.39749	PV1,  roof mounted solar system 3.87 kWAC. (18) modules: SUNEDISON F270KzD(18) microinverter: ENPHASE M-215-60-2LL-S22(E) 100A Panel, upgrade to (N) 125A Panel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23565	17041-10000-07277	1001 W D ST LOT 4-BLDG 13	90744	15	030B205  1417	7417012915	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM				INSTALLATION OF A NEW FA SYSTEM FOR A 3-FLOOR APARTMENT BUILDING. 2 FA PANELS AND 34 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23566	19041-10000-02914	2727 N ROSCOMARE ROAD	90077	5	156B145    98	4378013004	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.12572	-118.46383	$0 final fee due to AB1414Plan check for a 14.0 KW AC roofmounted system. Scope includes (49) module and IQ-7Plus microinverters interconnecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23567	13041-20000-11944	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	INSTALLATION OF OUTDOOR LIGHTING. AREA TO EXCEEED 30,000 SQ FT. PC FOR T24 ENERGY ONLY. SUBMITTED AS BACK ROOM DUE TO LARGE ILLUMIATED AREA. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23568	15041-20000-11261	3475 S CLARINGTON AVE 1-37	90034	5	120B165    64	4313001034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.02859	-118.40528	Plan check for a PV2 roof-mounted PV system. System size is 20 kWac and consists of (93) modules, (93) micro-inverters, and (1) 200-amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23569	16041-10000-45629	10250 W SANTA MONICA BLVD # 2400	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""DIN TAI FUNG"" Ste. 2400.  Install new panels and its circuits, lights and receptacles. Total effected area: 9064 sq.ft. ."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23570	17041-20000-42144	5414 N WAMEDA AVE	90041	14	165A227   196	5691018019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.14471	-118.19494	pv1install roof mounted pv system sized 10kw AC/ 12 kw DC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23571	16041-20001-00893	4513 S SLAUSON AVE	90230	11	111B161   977	4218001019	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			03/04/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.99734	-118.41311	3/4/2019changes to an approved set of plans.  change service to 120/240V single phase and removal of elevator.plan check for power only.  ((((Plan check for power and energy. New 4-story, 23 unit apartment building with 1000A 120V/208Y service. 11,437sqft. Fire Alarm Variance on file.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23572	16041-20001-09178	1250 N BEL-AIR ROAD	90077	5	147A153   463	4370029011	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM			PC Info Complete	08/03/2017 12:00:00 AM	ADDRESS	34.09618	-118.44375	Revisions to approved set of plans.  New loads added, changes to distribution equipment throughout, generator upgraded, UPS added, miscellaneus architectural and equipment layout revisions. All changes have been clouded and marked as Deltas 1 through 5.*****Previous Work Description*****PLAN CHECK FOR SINGLE FAMILY RESIDENCE.  SERVICE UPGRADE AND NEW ELECTRICAL SYSTEMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23573	16041-10003-41235	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	33.97954	-118.42015	PLAN CHECH FOR CHANGES TO APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 5. CHANGES INCLUDE MODIFICATION TO 50% OF OUTDOOR LIGHTING AND UPDATE OF TITLE 24 FORMS. ALSO REVISING LOAD CALCULATIONS. (OUTDOOR AREA = 99,521 SF).NOTE: PC ONLY, PERMIT IS PULLED UNDER ORIGINAL APPLICATION PCIS#16041-10000-41235	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23574	11041-10000-02941	118 W 5TH ST	90013	14	129A211   134	5149036004	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM			PC Info Complete	02/28/2011 12:00:00 AM	ADDRESS	34.04707	-118.24933	T.I. TO AN EXISTING RESTAURANT/LOUNGE.  T-24 ONLY.  FIRE ALAM WILL BE ON A SEPERATE APPLICATION. PERMIT WA SOBTAINED ON 1104190000-02316	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23575	15041-10000-02216	111 E UNIVERSAL HOLLYWOOD DR 29th floor	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM			Verifications in Progress	02/20/2015 12:00:00 AM	ADDRESS	34.13855	-118.36112	Plan check for power and energy. Project site is a high-rise building. Work will be done of the 29th floor. Total lighting area = 19,543 sq. ft. Project includes the installation of (2) 100 kVA UPSs, (2) 112.5 kVA transformers, and (5) panel boards. Fees to be verified by plan check engineer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23576	18041-10000-23294	4738 E VALLEY BLVD	90032	14	135A231   293	5223001014	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.06329	-118.18179	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23577	19041-10000-10251	3030 W 8TH ST	90005	10	132B197   465	5094012029	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.0576	-118.29246	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23578	14041-10001-04954	1756 S WASHINGTON WAY	90291	11	106-5A147  30	4228003015	RD1.5-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	33.9876	-118.46267	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6.095 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE6000A-US-ZB-U(17) MODULES: SUNIVA OPT265-60-4-1B0}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23579	14041-10001-09898	13885 W POLK ST	91342	7	228B153   422	2503005026	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.31999	-118.43604	((EXPEDITE FEES)))PV1 ROOFMOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23580	19041-10001-50299	8000 W MANCHESTER AVE	90293	11	096B153   618	4118002101	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM			PC Approved	03/06/2020 12:00:00 AM	ADDRESS	33.9594	-118.43534	Plan check for a 86.4 KW AC/ 85 KW DC roofmonted system. Scope includes (2) inverters, (196) modules and optimizer interconnecting through a load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23581	19041-10000-24735	6600 N TOPANGA CANYON BLVD 1100	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			PC Info Complete	10/23/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	plan check for a convenience store located inside Westfield Mall. Scope includes new lighting and equipment with a total area of 1,919-SQ FT.  2 feeders 225A each 3ph,3wBld: 19016-10000-00085	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23582	19041-10001-13064	1730 N WESTERN AVE	90027	13	148-5A193  68	5544007026	C4-1D, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			PC Info Complete	10/29/2019 12:00:00 AM	ADDRESS	34.10267	-118.3091	plan check for changes to approved set of plans - changes include addition and modification to title 24- delta #4 changes onlyNote: PC Only. Permit covered under the master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23583	10041-10000-17361	1652 N TOWER GROVE DR	90210	5	150B157   262	4384034013	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.10195	-118.42656	Plan check is for on site pump house for  6  future single family dwellings . New electric and diesel pumps  to get the water from street mains up to an an elevation of 260 feet above the street main for site use.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23584	16041-20000-05892	16501 W VENTURA BLVD #200/201	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.1578	-118.49275	Plan check Title 24 only for T.I. in existing space all new lights and existing circuit. Total area:8684 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23585	16041-20001-17271	18824 W KENYA ST	91326	12	210B121   590	2717022028	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM			PC Approved	06/02/2016 12:00:00 AM	ADDRESS	34.2697	-118.54412	RSES expedite fee per applicant request.  PV1.  Install 10.46 kW roof-mounted PV system.  (32) 327W modules with (2) 5kW rated central transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23586	13041-20001-35731	10429 N WHEATLAND AVE	91040	7	204B177    38	2542006002	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.2591	-118.358	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.25KW. 17 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23587	10041-20000-15726	14726 W BLYTHE ST	91402	6	189B149   413	2210021029	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.21509	-118.45377	firealarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23588	13041-10000-29599	3911 W FERNWOOD AVE	90027	4	147A203   334	5430026015	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.09646	-118.27766	PV1.  Install 2.5 kW DC roof-mounted photovoltaic system interconnect with main service panel.  Transformerless inverter: SolarEdge SE3000A-US.  10 modules: Trina Solar TSM-250PA05.18Separate permit for new 200A service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23589	15041-10000-40692	3850 W 59TH ST	90043	8	105B181   206	4004012013	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Expired	01/05/2018 12:00:00 AM	ADDRESS	33.98703	-118.34167	PV1, INSTALL 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: PV1-3.0-OUTD-S-US-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23590	16041-20000-22062	2178 S GUTHRIE DR	90034	5	126B169   340	4309015027	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.04333	-118.39272	Plan check for PV roof mounted system. System size: 4.2kW with 18 modules and 1 inverter(4.2kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23591	14041-10000-17558	15748 W ARMINTA ST	91406	6	189B141   161	2206002032	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.21378	-118.47651	permit to be pulled at EPC counter only. plan check for energy only. TI (E) OFFICE FOR FIRE DAMAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23592	19041-20000-50596	17540 W MARGATE ST	91316	5	171B129    79	2257003025	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.16755	-118.51593	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 11.34/10.0 KW AC CEC. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS AND A 10 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23593	12041-10000-15960	2174 N KENILWORTH AVE	90039	4	147A205    86	5431017006	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.09865	-118.26787	New 6.54kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23594	14041-10000-05668	2063 N ROSCOMARE ROAD	90077	5	150B145   138	4377013016	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.10767	-118.46362	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(8) MODULES: YINGLI YL250PL-29b(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23595	18041-20000-45089	5453 N DUBOIS AVE	91367	3	174B093   483	2044009008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.16981	-118.63996	Plan check for PV roof mounted system, system size: 14.4kw DC, 12.841kW AC with 40 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23596	19041-10000-23247	1615 S COLBY AVE	90025	11	126B149   171	4261013900	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.04458	-118.45269	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23597	17041-10000-06401	12848 W VICTORY BLVD	91606	2	180B161  1118	2332001009	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.18651	-118.41334	T-24, PC FOR ENERGY. TI TO AN EXISTING STARBUCKS. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1733 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23598	14041-10000-19075	1846 S GLENDON AVE	90025	5	129B153   638	4321001032	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			07/16/2014 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.04895	-118.43456	plan check for power and energy. Methane buffer zone. 1st floor and 2-4th floor typical plans. Fees to be added for T24 energy.  BLDG#14010-30-01431: new apartment building consists of 8 units.  4 story with roof top deck of type III-A on 1 level of type I-A subterranean parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23599	16041-10000-20654	725 W 53RD ST	90037	9	108B201   358	5001027021	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	33.99429	-118.28639	PV1 INSTALL NEW2.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(10) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23600	18041-10000-18152	2308 S CASTLE HEIGHTS AVE	90034	5	126B165   279	4309008003	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	12/01/2018 12:00:00 AM	ADDRESS	34.04345	-118.39761	New rooftop solar system and storage battery on SFD, (11) modules with (11) power optimizers, (1) 5.2 kW inverter, (1) 13.5 kWh ESS, (1) 125A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23601	18041-20001-31261	22120 W CLARENDON ST FLR 1, 2	91367	3	174B101   480	2169026106	(Q)CR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.01	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.16947	-118.6089	09/18/2018 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 874 sq. ft.Note: Building permit has been issued under 18016-10000-21957*****Previous Work Description*****LIGHTS, SWITCHES, OUTLETS  (16) IN 4 BATHROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23602	19041-20000-21491	10960 W WILSHIRE BLVD 805	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.058	-118.44597	ti to an existing commercial building adding new ighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23603	17041-10000-21655	523 W 6TH ST 6TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC FOR T24 ENERGY ONLY FOR RESTROOM REMODEL ON 6TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23604	19041-20001-03117	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM			PC Approved	03/21/2019 12:00:00 AM	ADDRESS	34.04342	-118.25478	3/21/19: Revisions to approved plans.  EM system distribution reconfiguration.  Approval for delta-12 revisions only.(((Plan check only for significant redesign to plans for permit issued under 14041-10000-27169.  Supplemental plan check. Conversion from office space to 2 floors retail and (6) live/work units.  (E) 2000A 240/120V 3ph-4w service with new distribution and loads throughout.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23605	14041-20000-07560	3002 W PEAK PL	90065	13	154-5A215 615	5458028037	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.11882	-118.23829	PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 1.3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23606	17041-10005-04927	1118 N MCCADDEN PL	90038	4	144B185   681	5532021029	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.09129	-118.33733	"Bulletin 8C"" UPDATED CHANGES ON THE SINGLE LINE-Panel HF1 deleted and 112.5 KVA xfmr supplied from a feeder t; Panel HRDF CORRECTLY IDENTIFIED AS A 400A panel; Remove MCB FROM INVERTER; CORRECTED BRANCH CKT ( OUTPUT SIDE OF UPS ) IDENTIFICATION ."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23607	15041-20002-34756	740 S RIDGELEY DR	90036	4	132B181   133	5089005011	[Q]R4-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			07/19/2019 12:00:00 AM			PC Info Complete	07/19/2019 12:00:00 AM	ADDRESS	34.06127	-118.35077	"07-19-2019 Changes to an approved set of plan, changes include feeder conductor to Aluminum, addtional of panel ""SE"" and associated load, lighting layout is lobby area."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23608	16041-10000-27429	10430 W PENROSE ST	91352	7	195B177   244	2404003003	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Expired	09/13/2018 12:00:00 AM	ADDRESS	34.2321	-118.35844	ROOF MOUNTED PV1 SYSTEM. 9.8 KW(DC)-8.74KW(AC), WITH 35 MODULES WITH MICROINVERTERS(ENPHASE M250).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23609	18041-20000-34640	1515 S HOLT AVE	90035	5	129B173   567	4303012059	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			09/11/2018 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	01/23/2021 12:00:00 AM	ADDRESS	34.05074	-118.37913	Plan check for power and energy. Project site is a new 5-story, 21-unit apartment building over 1 level of below-grade parking. Work includes a 1,600-amp service and a total lighting area of 20,456 sq. ft.Note: Building permit has been issued under 14010-30000-02204. See application comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23610	17041-20001-35099	1946 N HILLHURST AVE	90027	4	150B201   791	5590011010	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			PC Approved	03/09/2018 12:00:00 AM	ADDRESS	34.10665	-118.28725	CHANGES TO APPROVED T24 ENERGY.. TI TO THE LIGHTING. PLANCHECK ONLY. Tenant improvement/change of use of (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23611	19041-20000-50563	6020 N JUMILLA AVE	91367	3	177B117   608	2153021011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.17994	-118.56362	PV1. INSTALL 16.17 KW DC PV SYSTEM WITH (49) MODULES, OPTIMIZERS AND (2) INVERTERS (SE7600)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23612	18041-20000-38530	19701 S HAMILTON AVE ste 260	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.85221	-118.28625	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23613	14041-10000-09252	5701 N VISTA DEL MONTE AVE	91411	4	174B149   596	2244026006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.17397	-118.45017	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE .864KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23614	16041-20000-00721	5611 N FIGUEROA ST SUITE 2	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.10937	-118.19392	NEW INTERIOR NON-STRUCTURAL WORK FOR CHANGE OF USE FROM EXISTING RETAIL TO RECORD STORE/HAIR SALON.  1,282 sq ft.  Title 24 plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23615	17041-20000-45884	9051 W LARKE ELLEN CIR	90035	5	129B169  1031	4305023023	R1V2	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM	10/15/2021 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.04804	-118.38735	Two story SFD with attached garage and rec room over basement.  1200A 208Y/120V 3ph-4w service.  Plan check for power. Portion of the permit  fee is paid under building combo permit.Building permit # 17010-10000-04619	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23616	14041-20000-27059	523 W 6TH ST SUITE 516	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	TI TO SUITE 516. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23617	18041-10000-01000	17475 W REVELLO DR	90272	11	126B117   553	4416021058	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	05/21/2020 12:00:00 AM	ADDRESS	34.04037	-118.55723	PC FOR ESS INSTALLATION IN SFD.SCOPE INCLUDES 2 NEW TESLA POWER WALL TYPE 2  WITH NEW LOAD CENTER.(NO EXSITING PV)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23618	18041-20001-44149	2490 N CHEREMOYA AVE	90068	4	154-5A189 484	5580005016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Apartment			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.11577	-118.32088	01/11/2019 Changes to an approved set of plans. Single line diagram has been updated to show PV interconnection configuration on the field.*****Original Work Description*****PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 6 MODULES (SW 325 XL MONO) AND 6  MICROINVERTERS.  SYSTEM SIZE IS 1.95 KWdc and 1.68 KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23619	16041-10001-14109	20448 W CHASE ST	91306	3	192B109   260	2781025024	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.22447	-118.57916	Installation of 5.55 kw dc roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling(1) inverter: power-one pv1-5000-outd-us-A(16) modules: sunpower spr327-ne-wht-dDERATE MAIN BREAKER AND PLAN CHECK SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23620	15041-10000-23174	929 S NEW HAMPSHIRE AVE	90006	10	132B197  1000	5094025015	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	02/12/2024 12:00:00 AM	ADDRESS	34.05485	-118.29302	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8 KW INTERCONNECTED WITH MSP.(12) SUNPOWER 327W MODULES (1) SMA SB-3800TL-US -22 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23621	16041-10000-42701	18827 W ROSCOE BLVD	91324	12	192B121   726	2785019021	RA-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.22078	-118.54326	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total sqft = 44100	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23622	13041-20000-34259	735 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	03/27/2014 12:00:00 AM		Issued	03/27/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	PC FOR T24 ENERGY ONLY. EXISTING FAST FOOD SPACE IN MALL. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23623	15041-20000-03309	14517 W VENTURA BLVD	91403	4	166-5A151 105	2265010011	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.1512	-118.44937	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEEW CONTROLS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1333.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23624	14041-20000-11981	14241 W VENTURA BLVD	91423	4	165B153   330	2265019006	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Info Complete	10/02/2014 12:00:00 AM	ADDRESS	34.15025	-118.44356	Renovation to a 2-story existing commercial building (shell only).  New 800A serice, panels, branch circuits, outdoor lighting, and install lighting in tenant spaces on 2nd floor.  Also install lighting in common areas on 1st floor.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23625	10041-10001-06362	4570 N GRIFFIN AVE	90031	1	147A227    10	5303024003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco, Historic Highland Park	YES	1993.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Expired	09/17/2013 12:00:00 AM	ADDRESS	34.09568	-118.2017	INSTALLATION OF 266.5 KW (DC) OF PHOTOVOLTAIC SYSTEM ON THE GROUND(((((((((((((((((((((((((((( Change frome one feed and one transformer to two transgormers, 100 and 150 KVA.)))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23626	15041-10000-03970	7452 S MIDFIELD AVE	90045	11	099B173   109	4127002002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	33.96999	-118.37586	PV1 ROOF MOUNTED.  3 STRINGS 1 INVERTER. 2 OF 3 ARE COMBINED. 25 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23627	10041-10000-10463	604 S LINCOLN BLVD	90291	11	111B145   619	4243029024	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.00013	-118.46491	Ti in Smart & Final store. Plan check for T24 and Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23628	15041-10003-22479	140 E 53RD ST	90011	9	108B205   365	5101012004	R2-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	33.99412	-118.27245	CHANGE IN LOCATION OF SERVICE PANEL TO OUTSIDE OF HOUSE. NEW RATING OF MAIN. PC ONLY FOR CHANGES. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23629	15041-20000-28530	4810 N BALBOA AVE	91316	5	168B133   256	2289019151	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Expired	09/25/2017 12:00:00 AM	PIN	34.15777393	-118.50295447	PV1 ROOF MOUNTED SINGLE FAMILY DWELLING PHOTOVOLTAIC SYSTEM. ADDITION 2 MODULES TO EXISTING SYSTEM  OF 33 MODULES. USING MICROINVERTER SYSTEM. USING ENPHASE M250 INVETER. TOTAL SYSTEM SIZE 8.9KW AC.NOTE: REFFERENCE PREVIOUS ELECTRICAL PERMIT AND ZONING CLEARANCE #15041-20000-09875	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23630	18041-10001-43228	729 N LA CIENEGA BLVD	90069	5	141B173   334	4337003061	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM			PC Approved	12/07/2018 12:00:00 AM	ADDRESS	34.08445	-118.3767	TI IN A COMMERCIAL FACILITY. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL EFFECTED AREA IS 641 SQ.FTPERMIT FEES ARE PAID UNDER 18041-90000-43228	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23631	16041-10001-34072	21061 W SUPERIOR ST	91311	12	201B105   174	2746003004	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.24646	-118.59248	*Fee expedite per applicantNew PV2 rooftop solar installation, 72 kW AC.   (247)  CS modules,    (3) STP 24000TL inverters 480/277V 3ph.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23632	14041-10000-08939	734 W 124TH ST	90044	15	081B197   119	6117015002	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Closed	05/29/2015 12:00:00 AM	ADDRESS	33.91994	-118.2882	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23633	13041-20000-21013	2465 E 16TH ST BLDG B	90021	14	120A217   173	5168010919	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.01994	-118.22759	BLDG. B - CONSTRUCTION OF 101,89 SF SHELL BLDG.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23634	19041-10000-35584	11552 W CANTLAY ST	91605	2	186B169   980	2316029008	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.20241	-118.38422	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 38 MODULES (LG NEON) WITH 38 MICROINVERTERS (IQ7PLUS-72). SYSTEM SIZE IS 12.73KWdc AND 11.02KWac. SCOPE ALSO INCLUDES NEW 200A COMBINER BOX. PANEL UPGRADE UNDER EXPRESS PERMIT	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23635	19041-10000-12061	1720 E CESAR E CHAVEZ AVE	90033	14	129A221     5	5174008037	C2-1-RIO-CUGU, [Q]R5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.05052	-118.21669	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23636	15041-10000-24139	8500 W BEVERLY BLVD #788	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	EAlterations inside the storage area at the back  of the club ;plan chk is for titoe 34	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23637	16041-20000-24811	17116 W KNAPP ST	91325	12	198B133   406	2692020039	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.2383	-118.50633	$0 permit fee due to State Senate Bill SB 1222Plan check for PV roof mounted system. System size: 12kW with 60 module and 2 inveters(6.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23638	17041-10000-12602	7330 N FIGUEROA ST	90041	14	162A231   184	5709006005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.13696	-118.1878	TI TO MAKE NEW CHARTER SCHOOL. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23639	16041-20000-40858	12644 W HESBY ST	91607	2	171B161   923	2357008014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.16205	-118.40871	"""0$ permit fees due to senate bill 1222""Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 400A split bus MSP. 12kW (6+6) ungrounded system. (50) 300W pv modules. Each module has a 300W power optimizer."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23640	12041-10000-10426	2112 W COLORADO BLVD	90041	14	162A223   124	5686003016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	34.13895	-118.21246	CHANGE OF USE FROM RETAIL TO HAIR SALON, ADD NEW RESTROOM.  Occupancy Load is less than 99 and load is less than 200A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23641	18041-20000-01292	641 N CRANE BLVD	90065	1	150A223   111	5466006017	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.10672	-118.20996	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (1) load center, and (25) modules. PV system is interconnecting to a center-fed MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23642	14041-10000-34322	1800 N BAKER ST	90012	1	138A219    30	5414027***	GW(CA)	East Los Angeles	Silver Lake - Echo Park - Elysian Valley		YES	9800.10	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.07229	-118.22572	Plan check for power. Scope of work include the installation of a new high voltage switchgear section. Switchgear is connected to a new step-down transformer which supplies a new 1200 amp distribution board, connected to existing loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23643	14041-10000-06507	648 S BROADWAY	90014	14	127-5A211  32	5144002023	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.0454	-118.25294	New fire alarm for a 5 sotory commercial,   addressable system   1 panel and 126 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23644	11041-20000-03938	13076 N GLENOAKS BLVD	91342	7	222B149    49	2505024013	C2-1, RA-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.30824	-118.45026	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23645	16041-10002-00682	1011 W 65TH PL	90044	8	105B197  1395	6014004019	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Issued	12/07/2016 12:00:00 AM	ADDRESS	33.97994	-118.29229	PC FOR AN EXISTING PV SYSTEM. SCOPE INCLUDE REFEEDING EXISTING PV SYSTEM FROM THE GUEST HOUSE METER TO THE MAIN HOUSE METER.Permit is paid under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23646	19041-20000-53146	6380 W LINDENHURST AVE	90048	5	135B173   612	5510020018	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.06631	-118.36759	PV1. INSTALL 9.05 KW DC ROOFMOUNTED PV SYSTEM WITH (27) MODULES, MICROINVERTERS AND (2) TESLA ENERGY STORAGE SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23647	17041-10000-03065	8401 S FIGUEROA ST	90003	8	097-5A201 105	6032017001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.96194	-118.28296	FULL PC FOR POWER AND ENERGY FOR AN EXISTING COIN LAUNDRY BUILDING. SCOPE INCLUDES A NEW 1200A 120/208  3PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 22280 SQ. FT. B# 17014-10000-00637	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23648	16041-10000-08008	7118 N JORDAN AVE	91303	3	183B105   328	2111025021	[Q]R3-1-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			03/07/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.19971	-118.60272	FULL PC FOR NEW 9-UNIT 2-STORY PLUS ONE REC ROOM APARTMENT BUILDING WITH (STREET LEVEL) PARKING GARAGE (per DIR-2015-1833-SPP) 5 TYPE UNTS.B# 15010-20000-00706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23649	15041-20001-42767	526 N SALTAIR AVE	90049	11	138B141   500	4429020007	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM			PC Approved	12/30/2015 12:00:00 AM	ADDRESS	34.07106	-118.47555	Expedited RSES plan check per applicant request.  (((PV1. Install 18.996 kW DC roof-mounted, utility-interactive PV system.  (2) SMA SB6000TL-US and (1) SMA SB7000TL-US inverters with (58) SunPower SPR-327 modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23650	19041-10000-41162	12521 W BRANFORD ST	91331	7	201B161   635	2624018017	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.24629	-118.40609	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR/OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23651	17041-20000-43278	229 N BURLINGTON AVE #2	90026	13	136-5A207 286	5159006009	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM			Reviewed by Supervisor	12/28/2017 12:00:00 AM	ADDRESS	34.06717	-118.26626	plan check for power only.NEW 4 STORY SINGLE FAMILY DWELLING W/ ATTACHED GARAGE. (PART OF NEW SMALL LOT SUBDIVISION). 2 of 6 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23652	14041-20001-26979	6438 N ALDEA AVE	91406	6	180B133   450	2230022007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	34.1879	-118.50777	PV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN. TOTAL OF 3 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23653	16041-20001-36606	4904 N VAN NUYS BLVD	91403	4	169-5A151  84	2248007032	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.15955	-118.44848	Plan check for energy only. Office addition and TI to existing office area and restroom. New lighting and receptacles. 548sqft. Permit pulled under parent application #16041-20000-36606.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23654	12041-20000-19446	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.06222	-118.35208	T.I. to a high rise building on the 18th floor, suite #1800.  Install general/emergency lighting. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23655	18041-10000-29312	1749 W 42ND PL	90062	8	114B193  1076	5021028036	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM			Verifications in Progress	09/24/2018 12:00:00 AM	ADDRESS	34.0065	-118.31062	INSTALLATION OF 3.54KW ROOFMOUNTED SYSTEM TO AN EXISTING PV SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23656	13041-10000-13959	5915 N JELLICO AVE	91316	5	177B129   804	2254002029	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.17787	-118.51757	PV1 ROOF MOUNTED INSTALLATION ON A SINGLE FAMILY DWELLING. SYSTEM SIZE IS 4.41 KW, THREE STRINGS OF 6 MODULES. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: POWER-ONE # AURORA PVI-4.2-OUTD-S-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23657	10041-20000-15777	15230 W SAN FERNANDO MISSION BLVD #B103	91345	7	210B145   126	2664004005	P-1, [Q]CM-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00, 1094.00	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.27224	-118.46456	lighting and power for office area. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23658	15041-10000-16507	1200 S BROADWAY	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.03792	-118.26026	pc for methane mitigation system (methane design Level 3) for a new mixed used aprtment building,  Fire department approval on separate plans. Changes on plans include update of battery calculations and clarifications with wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23659	19041-10000-14406	18051 W SHERMAN WAY	91335	3	183B125    87	2121002012	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.20134	-118.52678	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23660	19041-10000-51540	8741 W ALDEN DR	90048	5	138B169   338	4334002027	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	07/29/2020 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.07541	-118.38312	T.I. FULL POWER & ENERGY PC FOR A  (N) MEDICAL CLINIC CONNECTED TO AN EXISTING 600AMP 120/240V 3PHASE 4WIRE SERVICE. TOTAL AFFECTED AREA 4331sqft.SCOPE OF WORK INCLUDES INSTALLATION OF NEW EQUIPMENT.************************************************************************ *********PER BUILDING APPLICATION# 19016-10000-31875:CHANGE OF USE AND T.I. FROM (E) RESTAURANT TO (N) MEDICAL CLINIC (NON-OSHPD) WITH STRUCTURAL UPGRADE,**********************************************************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23661	15041-10000-18358	4217 E CAMINO REAL	90065	1	147A221    25	5465026005	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			Reviewed by Supervisor	06/22/2015 12:00:00 AM	ADDRESS	34.09887	-118.21497	PV1 INSTALL 11.13 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(42) MODULES: KYOCERA #KU2656ZPA(1)INVERTER: SOLARDGE SE10000A-US-ZB	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23662	14041-10000-14399	629 E MILFORD ST	90042	14	150A231   112	5312023066	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Expired	07/13/2016 12:00:00 AM	ADDRESS	34.10626	-118.18228	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23663	16041-20000-29823	12700 W VENTURA BLVD 2ND FLR	91604	2	162B161    29	2384022049	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.14449	-118.40998	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG.  TOTAL SQUARE FOOTAGE 3308.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23664	15041-20000-04313	9541 N MASON AVE	91311	12	201B109   308	2748003092	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.24405	-118.57998	PLANCHECK FOR T24 ENERGY. BATHROOMS. 400 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23665	15041-10003-31717	266 S HARVARD BLVD STE 200 &-205	90004	10	135B193   181	5517019030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.06926	-118.30396	Delta 2 changes to permitted set of plans-revised lighting plan ( reduced installed wattage) ,revised energy compliance forms,and transformer  chaged from 18KVA to 15KVA. All changes are clouded and marked as Delta 2(((((((FULL PC FOR POWER AND ENERGY. TI ON EXISTING 4-STORY COMMERCIAL BUILDING (AMBULATORY SURGERY CENTER, NOT AN OSHPD 3, UNDER DOCTOR'S LICENSE).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23666	17041-20001-09879	12601 W PIERCE ST BLDG 5, 6	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 5 and 6).10.5kW ungrounded system. (21) AP Systems YC500i microinverters. (42) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23667	16041-10003-26321	7654 N TAMPA AVE	91335	3	186B117    46	2104012038	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Approved	04/24/2017 12:00:00 AM	ADDRESS	34.20985	-118.55333	CHANGES TO AN APPROVED SET OF PLANS. CHANGES NOTED UNDER DELTA 1 CHANGES.SCOPE INCLUDES REPLACEMENT OF TWO EXISTING PANELS WITH NEW 250A PANELS. ORIGINAL PLAN PERMIT UNDER 16041-10000-26321Plan check for PV2 roof mounted system. System size: 70kW with 2 inverters(15kW), 2 inverter(20kW) with 202 modules connected to MSP1 and MSP2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23668	17041-20001-30118	13951 W ENADIA WAY	91405	2	183B153   197	2216006008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.2004	-118.43747	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (43) modules, (1) load center, and (2) Tesla Powerwalls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23669	18041-20000-25710	7001 W FRANKLIN AVE	90028	4	150B181   567	5549017011	[Q]R5-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM			PC Info Complete	09/19/2018 12:00:00 AM	ADDRESS	34.10427	-118.34205	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,497 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23670	15041-10000-18754	10625 W TABOR ST	90034	5	120B161   930	4314011014	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.02357	-118.41014	PC FOR POWER AND ENERGY, NEW APARTMENT BUILDING  WITH 5 STORIES AND 32 UNITS PLUS ONE SUBTERRANIAN LEVEL. TOTAL AREA 20,166 SQ FT(INDOOR) + 12439 SQ FT(OUTDOOR).PER APPLICANT FEES.B# 15010-10000-02105	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23671	18041-10000-45192	1370 S ESPERANZA ST	90023	14	118-5A227 277	5191023001	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			PC Approved	11/28/2018 12:00:00 AM	ADDRESS	34.01731	-118.20087	PLAN CHECK FOR TITLE 24 ONLY FOR CHANGE OF USE TO LABRATORY SCOPE OF WORK INCLUDES 1790 SQFT AREA.BLD# 18016-10000-37158	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23672	14041-10000-11565	725 S FIGUEROA ST # 2200	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.04886	-118.26071	permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A connected load. Inspector to verify if more is being installed in the building. Emergency lights for high rise being installed. BLDG#14016-10-07959: TENANT IMPROVEMENT- INTERIOR REMOVE NON-BEARING PARTITIONS.  ERECT NEW NON-BEARING PARTITION.  REWORK (E) LIGHTING (E) CEILING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23673	14041-10000-20559	5606 W SANTA MONICA BLVD	90038	13	144B193   774	5536018015	[Q]C2-2D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.09062	-118.31166	Title 24 plan check only.  Total area = 1,654 sq. ft.Change of use from a retail space to a loan office including interior lighting and recepticle alterations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23674	13041-20000-12176	7810 N QUARTZ AVE	91306	3	189B117   770	2106029018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.21251	-118.56401	PV1 PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12.74KW. USING CENTRAL INVERTER STANDARD PLAN. USING 52 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23675	12041-10000-27029	6917 W 85TH PL	90045	11	096B161   525	4112002011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	33.9605	-118.41198	PV1 SOLAR INSTALLATION 3.43KW. ROOF MOUNTED ENPHASE MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23676	12041-20001-19035	21255 W BURBANK BLVD Bldg D-6th Floor	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM			PC Approved	12/27/2012 12:00:00 AM	ADDRESS	34.17432	-118.59446	"Modification to previously approved set of plans to add a ""Phase 2"" addtional work and areas.<<<Remodel 6th floor of the building.  Plan check for power and energy and emergency lighting.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23677	17041-10000-04654	818 W 7TH ST #740	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM			PC Info Complete	02/14/2017 12:00:00 AM	ADDRESS	34.04895	-118.25943	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 665 SQ. FT. B#16016-10000-28796	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23678	18041-20000-46520	3900 N STANSBURY AVE	91423	4	162B153  1094	2274027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.14084	-118.44264	T24 plan check only. Interior remodel and addition to (E) commercial building. Plan check for energy. Total square footage = 4440 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23679	15041-10000-23274	1940 S FIGUEROA ST	90007	9	123A205    12	5126008011	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Info Complete	09/30/2015 12:00:00 AM	ADDRESS	34.03322	-118.27253	PC FOR POWER AND ENERGY, ADDING SERVICE AND REPAIR.EXTERIOR REMODELLING.  TOTAL AREA13000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23680	13041-10000-23154	421 S COLYTON ST	90013	14	127-5A215 301	5163025007	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Expired	09/29/2015 12:00:00 AM	ADDRESS	34.04274	-118.23653	sthird building ( 24 units apt bldg 3- stories)supplied from 5000A service section located at 440 S Seaton St. Swichboard is 800A 277/480V . Each apt feeder has a 25KVA 1ph xfmr stepping the voltage down to 120/240V to supply the apt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23681	19041-10000-00154	5555 W MELROSE AVE S17-18-HVAC	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	11/11/2020 12:00:00 AM	ADDRESS	34.08363	-118.32191	PLAN CHECK FOR POWER INSTALLING NEW DISTRIBUTION BOARD WITH 1000AMP TO SUPPORT NEW HVAC ON ROOF ADDING NEW 2400V MEDIUM VOLTAGE FEEDER. SCOPE INCLUDES ADDING OVER 400 AMP LOADS ON THE NEW PANEL. BLDING# 18016-10000-40962	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23682	15041-20002-40832	13204 N AZORES AVE	91342	7	225B157   786	2512012040	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.31029	-118.42255	Fee is $0.00 due to 2012 CA State Senate Bill 1222.3.7.2016 - Plan check for modifications to approved set. Revise grounding electrode system on SLD.====PV1, roof mounted solar 6kW AC, interconnect with (E) 200A service.(26) hanhwa q cell Q PRO G4 260(1) SE6000A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23683	18041-10000-06206	5955 N DE SOTO AVE #240	91367	3	177B105    78	2149002027	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.17888	-118.59071	PC FOR TI TO AN OFFICE SPACE. REPLACE EXISTING FLOURESCENT FIXTURES WITH NEW LED FIXTURES. T-24 ENERGY ONLY. TOTAL AFFECTED AREA IS 2479 SQ.FTB#18016-20000-01305	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23684	16041-20000-22115	8811 W BURTON WAY 1st Floor	90048	5	138B169   687	4334011063	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			06/23/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.07249	-118.38417	Plan check Title 24 only in 1st floor lobby existing appartment. Total indoor lighting area: 3,493 sq ft. Total outdoor area: 10,446	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23685	14041-20001-01734	24221 W HILLHURST DR	91307	12	186B089   638	2027043024	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.20317	-118.65195	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5KWAC. 3 STRINGS 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23686	19041-20000-11845	10015 N PETIT AVE	91343	12	204B137   925	2685003011	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Re-Activate Permit	06/10/2020 12:00:00 AM	ADDRESS	34.25254	-118.49818	PV1.  Install 8.99 kW roof mounted grid tied PV system.  (31) modules with 9 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23687	17041-20000-34749	13113 W VAN NUYS BLVD unit a	91331	7	210B161   744	2535018026	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.26875	-118.41881	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23688	19041-10000-46465	1909 N ROSALIA ROAD	90027	4	150B201  1001	5590011018	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			11/11/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	04/25/2020 12:00:00 AM	ADDRESS	34.10568	-118.2865	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 6.4KWdc (6.3 KWac) USING 20 (SUN POWER E19/320) MODULES  AND 20 ( ENPHASE IQ7X) MICROINVERTERS. NEW ESS TESLA POWER WALL. CONNECTED TO A 200  EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23689	14041-10000-27414	5708 N TYRONE AVE	91401	4	174B153   516	2245021044	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.17423	-118.4442	Installation of roofmounted residential solar PV standard plan. # of inverters: 2. System size: 7.6kW. # of modules: 35.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23690	17041-10000-31315	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	33.93845	-118.42964	"PC FOR TEMP INSTALLATION OF 800KVA GENERATOR. GENERTATOR TO PARTIALLY ENERGIZE  ""MDB"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23691	13041-10001-09307	818 S BROADWAY #114	90014	14	127-5A209 160	5144016064	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM			PC Approved	06/21/2013 12:00:00 AM	ADDRESS	34.04318	-118.255	"Modification to approved set.  Housing of fixture-2 changed from 4"" aperture to 6"" aperture.  Original work description: RENOVATION OF SMALL RETAIL SPACES FOR JEWELRY STORE. TOTAL AREA 1000 SQ FT. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23692	19041-20000-23235	5174 N DUMONT PL	91364	3	171B109   288	2166045003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.16264	-118.57922	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.395KW DC/10.535 KW AC. SCOPE OF WORK INCLUDES (37) PANASONIC PV MODULES WITH P400 OPTIMIZERS, A 125A SUB PANEL, A SE3800H-US  INVERTER AND A SE7600H-US INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23693	10041-10000-09260	6240 W FOOTHILL BLVD	91042	2	198B205   182	2572001028	(T)(Q)C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.24093	-118.26727	INSIDE A SUPERMARKET, AN AREA IS DEVELOPED FOR BANK USE BY THE CHASE BANK.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23694	15041-10000-02536	1552 W ROCKWOOD ST	90026	13	135A207   285	5159013016	RD1.5-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.06355	-118.26143	Plan check for a methane gas control detecting system with (59) devices and (1) control panel, & (1) communication panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23695	09041-10002-23033	2614 W 7TH ST	90057	1	133-5A201 234	5141013022	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Apartment			09/10/2010 12:00:00 AM	11/15/2011 12:00:00 AM		Permit Finaled	12/15/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	Changes from  previously approved plans indicated as Delta 2.  Revised single line diagram to show 2500 amp service swbd with 3ea 600A feeders to distribution boards for the apartment units and a 1000A feeder to supply house loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23696	11041-20000-24066	11734 W WILSHIRE BLVD BLDG 'C'	90025	11	129B145   644	4263009030	R4-1, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.04882	-118.46133	INTERIOR TENANT IMPROVEMENT IN (E) LOBBY OF BUILDING 'C' NON-STRUCTURAL. Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23697	13041-10000-31655	7963 N VAN NUYS BLVD	91402	6	189B149   310	2210019004	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.21603	-118.44897	"FA for building B - banquet hall. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~""COMPLY WITH DEPARTMENT ORDER effective date 3/21/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". All permits shall be for the same time period limitation. If additional assistance is needed, please call Inspector ERNEST LEOS at (818)374-9845 of GENERAL ENFORCEMENT NORTH.  CEIS Case Number is 221168. (Created: IMSV7 / 03-18-08)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 71520  -- Building/Electrical/MechanicalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issued with effective date 03/21/2008 by Inspector ERNEST LEOS at phone# (818)374-9845.  CEIS Case Number is 221168."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23698	12041-20000-07156	9911 W PICO BLVD	90035	5	129B165    65	4330005043	C4-1VL-O	West Los Angeles	West Los Angeles			2690.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.05339	-118.40441	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23699	16041-10000-37321	6555 W BARTON AVE 5th FLOOR	90038	4	144B185  1069	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.08785	-118.33475	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 5TH FLOOR. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES FOR A NEW OFFICE SPACE. TOTAL AREA 10874 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23700	17041-20000-43129	7842 N MELBA AVE	91304	12	189B093   505	2020023007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	01/06/2018 12:00:00 AM	ADDRESS	34.21298	-118.63443	Plan check for solar pv system, roof-mounted array on SFD.22.8kW ungrounded system. (2) 11.4kW SolarEdge inverters.(87) 330W pv modules. (87) 400W power optimizers.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23701	15041-10000-23651	2215 E ALCAZAR ST	90033	14	135A227   139	5202001008	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.06357	-118.20153	INSTALLATION OF FIRE ALARM DEVICES = 1008 NEW FIRE ALARM SYSTEM(5) CONTROL PANEL(1) FIRE ALARM PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23702	14041-20001-03328	7722 N RESEDA BLVD	91335	12	189B125   819	2102021039	R3-1, RD5-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.21126	-118.53586	(((expedite fees)))pv2 commercial rooftop photovoltaic system. total system size 48.6kw AC using 2 central inverters. service is 120/240 delta connected	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23703	16041-10000-38593	1701 S SANTA FE AVE	90021	14	120A217    30	5167010014	M3-1-S-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.02453	-118.23016	Remove HID fixtures and replace with new LED fixtures. Outdoor Title 24 only. Total sqft = 54450	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23704	13041-10000-29573	6423 S ARLINGTON AVE	90043	8	105B189  1512	4007024014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.98126	-118.31881	PV1.  Install 5.75 kW DC roof-mounted solar array, interconnect with main service panel.  Inverter: Solaredge Se6000A-US.  23 modules: Hanwha Hsl60P6-Pb-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23705	18041-10000-26044	707 W WILSHIRE BLVD #3750	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	PLAN CHECK FOR T24 ONLY, INTERIOR TENANT IMPROVEMENT TO EXISTING OFFICE SPACE. NEW CIRCUITS USING EXISTING PANELS. TOTAL AREA: 2,321 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23706	14041-10000-31530	1633 W CORTEZ ST	90026	13	136-5A207 225	5159022023	R4-1	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.0676	-118.26177	Installation of roof mounted solar PV array.  Total system size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23707	14041-20001-35890	7887 N CLAYBECK AVE	91352	2	189B181   313	2405015015	R2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.05	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM			PC Approved	01/16/2015 12:00:00 AM	ADDRESS	34.214	-118.35227	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 7.5KW AC USING TRANSFORMED INVERTER. NONSTANDARD PLAN. USING 4 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23708	19041-10000-27521	18235 S FIGUEROA ST	90248	15	063B201   197	7339008024	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	33.8656	-118.28185	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23709	17041-20000-07542	20929 W VENTURA BLVD Building B	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600-amps.Note: Building application has been generated under 16016-20000-22113	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23710	13041-10001-07850	334 S MAIN ST #1101	90013	14	129A213   129	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.04841	-118.24668	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 13041-10000-07850. CHANGES TO GENERAL AND EMERGENCY LIGHTING.****************************************************FIRST TIME TENANT OF RETAIL SPACE IN MIX BUILDING. PC FOR POWER AND ENERGY. TOTAL AREA 2551 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23711	15041-10000-06164	912 E 12TH ST SUITE A	90021	14	123A211   151	5132013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.03176	-118.24942	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING CIRCUITS AND PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2164	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23712	19041-10000-32715	3690 E NOAKES ST	90023	14	117A227    90	5192017006	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			PC Info Complete	01/14/2020 12:00:00 AM	ADDRESS	34.01407	-118.19672	POWER AND ENERGY PLAN CHECK FOR CHANGE OF USE AND TENANT IMPROVEMENT. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 11,400 SQ.FTB# 19016-10000-26124	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23713	17041-10000-04390	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Info Complete	02/09/2017 12:00:00 AM	ADDRESS	34.04538	-118.26389	PC for title 24 only. Change of use from classroom/ office to office with tenant  improvement in the basement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23714	16041-10000-26967	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.04338	-118.26581	Plan check for T-24 only.  TI on (E) Commercial build.  Scope of work includes: THE LOS ANGELES CLIPPERS LOCKER ROOM AND THE VISITING NHL TEAM LOCKER ROOM.  NO CHANGE IN USE OR OCCUPANCY.  Affected area: 2,743 S.F.(B# 16016-10000-15895)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23715	11041-10000-24622	1555 N VINE ST #106	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.09923	-118.32707	T.I. to a nail spa.  New circuits and panelboard.  Full plan check requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23716	13041-10000-27885	11809 W ROSE AVE	90066	11	117B153   416	4250003002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.01806	-118.43674	PV1, 6.76KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(26)modules: {Suniva {#OPT260-60-4-100}}] with optimizers: [SOLAREDGE {POWERBOX 300W OP300-MV-TYCRM-2NA}. (E) 200A MAIN. THE 300W OPTIMIZERS WILL BE CHARGED UNDER NON-DWELLING POWER EQUIPMENT. BRAND NEW SUBMITTAL PER APPLICANT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23717	16041-10000-07634	877 S FRANCISCO ST	90017	14	129A207    90	5144023038	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.04791	-118.26383	PC FOR A NEW FIRE ALARM SYSTEM TO A MIXED USED BUILDING (Apartment/retail/parking garage) WITH TWO LEVELS OF SUBTERREAN PARKING STRUCTURE. SCOPE INCLUDES 2665 FA DEVICES, 1 FA PANEL, AND 1 COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23718	10041-20000-21114	615 E 36TH ST #101	90011	9	117A207   291	5121002019	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Closed	12/28/2012 12:00:00 AM	ADDRESS	34.01371	-118.26458	T.I. to USC building of couselor 101E, storage 101F, and corridor as shown on plans.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23719	13041-20000-36030	332 E 91ST ST	90003	9	094-5A205 178	6041028026	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	33.95368	-118.26829	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23720	18041-20001-26134	1800 N WINONA BLVD	90027	13	150A195   249	5544012044	R3-1	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.10377	-118.30182	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 70.72 kWdc/61.52 kWac-CEC and consists of (5) 12 kWac rated inverters, (1) load center, and (208) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23721	11041-20000-18324	333 E 2ND ST	90012	14	129A215    61	5161017023	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.04886	-118.24076	Plan check T24 Energy for existing restaurant TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23722	13041-10000-30822	519 W 76TH ST	90044	8	099B201    24	6020021028	[Q]R3-1	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	33.97087	-118.28346	PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 2 STORY. SYSTEM SIZE: 7.25 KW.(29) TRINA SOLAR # TSM-250PA05.18(29) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23723	15041-10000-30112	899 S FRANCISCO ST	90017	14	129A207   155	5144023054	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	34.04731	-118.2643	Full plan check for an 18-story hotel T.I build out. Scope includes (17) typical unit; total area is 258,716-SQ feet for T-24.Reference Application :  # 14041-10000- 35273  for core and shell with follwoing description (((Plan check for New 18 story Hotel: 350 guest rooms on 14 floors, and a 4 story podium with pool deck, meeting and ballrooms, Restaurant/retail space. 2 level of parking. Core and Shell. Service size: 1200A at 4160V. PERMIT FEES UNDER INSPECTION DUE TO PARTIAL PLAN CHECK DONE UNDER 14041-10002-35273)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23724	12041-10000-15305	5317 E YORK BLVD	90042	14	156A227   382	5478003014	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	08/22/2012 12:00:00 AM	ADDRESS	34.12031	-118.19996	New fire alarm system for a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23725	14041-20000-18874	14728 W KESWICK ST	91405	6	186B149    30	2210028004	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM			Corrections Issued	07/15/2014 12:00:00 AM	ADDRESS	34.21015	-118.45407	TI TO EXISTING SPACE. WHOLESALE. NEW LIGHTING. PC FOR T24 ENERGY ONLY. PER BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23726	16041-10000-14273	6801 W HOLLYWOOD BLVD A3-319	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	TI, change of use from office to take out restaurant in an (E) build. New customer area, kitchen, and storage.PC for energy only. Total area: 515 sq.ft** New contractor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23727	15041-10000-24826	15320 W CABRITO ROAD	91406	6	189B145   719	2222001007	M1-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.21558	-118.46689	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23728	19041-20000-30130	4375 E O'NEIL ST	90032	14	141A229   317	5214005011	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.07995	-118.19047	PV1.  Install 7.67 kW roof mounted grid tied PV system.  (21) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23729	16041-10000-43885	700 W 7TH ST G580	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR TENANT TI. TITLE 24  ENERGY ONLYSCOPE INCLUDES Power and lighting for tenant G580. TOTAL  AFFECTED AREA 430 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23730	17041-10001-03184	10250 W SANTA MONICA BLVD # 2750	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	[Changes to approved set noted under Delta-2. ] This is plan check only due to architectural changed. Revise the Reserve area, readjust photometric calculation and T-24 power allowance calculation. Permits is covered under the master plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23731	13041-10000-04331	3430 S VERMONT AVE	90089	8	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.02479	-118.29132	FA FOR NEW TEMP 1 STORY MODULAR RESEARCH FACILITY USC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23732	12041-10000-16648	13444 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15935	-118.4262	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #10	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23733	17041-10001-18140	1888 S CENTURY PARK EAST 150	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.06104	-118.41402	PC FOR CHANGES TO APPROVED SET.  ALL CHANGES MARKED UNDER DELTA 4. SCOPE INCLUDES CHANGES TO FIXTURES IN SPACE TO REFLECT FIELD INSTALLATION AND REVISION TO T-24 FORMS. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23734	17041-20004-43118	269 S MARIPOSA AVE	90004	10	135B197   154	5518007026	C2-1, R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.06948	-118.29938	1/15/2019plan check only changes to an approved set of plans.  changes to include revised unit feeder calculations and residential distributions.  addition of electric appliances to 122 units.  change unit feeders to copper.  changes are noted delta C only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23735	14041-20000-06381	15260 W VENTURA BLVD SUITE 1700	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.15356	-118.4658	pc for t24 energy only. existing offices. new lighting. permit to be issued under this application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23736	17041-20000-04674	1730 N LA BREA AVE	90046	13	147B181    78	5548002037	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Issued	01/12/2018 12:00:00 AM	ADDRESS	34.1024	-118.34531	0$ permit fees due to senate bill 1222PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 23.9 KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23737	15041-20000-06867	891 S BRONSON AVE	90005	4	132B189   840	5092002019	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.05634	-118.3209	Plan check for PV roof monted 8kW system with (32) 250w microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23738	15041-10006-14620	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Info Complete	10/23/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC for power only for addition of two power stations in terminal 7. All changes clouded under delta 41.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23739	11041-10000-02364	1067 S GLENDON AVE	90024	5	132B153  1096	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	06/08/2011 12:00:00 AM	ADDRESS	34.06138	-118.44457	CHANGE OF USE FROM RETAIL TO RESTAURANT. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23740	18041-20001-11355	20433 W NORDHOFF ST	91311	12	195B109    61	2781001036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.232	-118.57867	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 66.6 kWac and consists of (2) inverters, (240) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23741	16041-10001-02085	17532 W SUPERIOR ST	91325	12	201B129   281	2755009020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM			PC Approved	02/12/2016 12:00:00 AM	ADDRESS	34.2466	-118.51692	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{PV1, Install 12.19 KW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (2) INVERTER:  ABB PVI-4.2 & 6000-OUTD-S-US-Z-A.  (46) Modules: KYOCERA  KU2656ZPA}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23742	14041-10000-07999	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.06488	-118.47066	permit to be pulled at EPC only. Plan check for energy only. not hazardous and less than 400A per applicant.  emergency lighting. (Girl's school lab)BLDG # 14016-10-05620:RENOVATION/ALTERATION OF INTERIOR CLASSROOM SPACES CONSISTING OF FINISHES, MILLWORK, PLUMBING, LIGHTING FIXTURES AND HVAC.  NO NEW FLOOR AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23743	12041-20000-20999	7523 N SYLVIA AVE	91335	3	186B117   336	2104018042	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM			Reviewed by Supervisor	11/08/2012 12:00:00 AM	ADDRESS	34.2071	-118.55257	Plan check for PV system. Single family dwelling. 4.32 KW. PROJECT ABANDONED. CHANGE OF CONTRACTOR to 12041-20000-25302.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23744	13041-10001-12511	122 W 4TH ST 1ST	90013	14	129A211    63	5149023013	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	34.0485	-118.24808	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 13041-10000-12511.************************************************************************13041-10000-12511 DESCRIPTION: PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. T.I. OF EXISTING RESTAURANT (1,365 SF)- STOREFRONT & INT REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23745	13041-10000-27463	1501 N SOTO ST	90033	14	135A227   118	5202002019	PF-1, [Q]C2-1	East Los Angeles	Northeast Los Angeles			2033.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.06079	-118.19919	MONUMENT SIGN #2- SOUTHWEST CORNER OF ALCAZAR/SOTO  plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23746	19041-10000-20516	5500 W WASHINGTON BLVD	90016	10	123B177    29	5063021034	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.03735	-118.36334	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23747	11041-20000-01843	555 W 5TH ST 12th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check T24 energy and emergency lighting  plan check 12th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23748	14041-20000-05294	22101 W LONDELIUS ST	91304	12	195B101   253	2010007020	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.22941	-118.60836	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23749	12041-10004-30784	12751 W MILLENNIUM B	90094	11	102B161  1235	4211033050	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/28/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	Change to approved set by modifying the AIC rating of panel MMB1 from 100kAIC to 65KAIC . One change only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23750	12041-10000-06314	1530 W PALOS VERDES DR NORTH BLDG J	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77933	-118.30453	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building J. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23751	13041-10001-05744	380 WORLD WAY #T73-T74	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	09/26/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Delta 7 revisions- adding 2 ea FC units for the tenant spacePLAN CHECK POWER AND ENERGY FOR CONCESSION SPACE T-73 & T-74 (LUCKY FISH)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23752	17041-20002-12250	524 E WASHINGTON BLVD	90292	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	PIN	34.02811119	-118.25991573	08-09-2018 Changes to an approved set of plan. Changes include Remove lighting fixture L31, L32, L33 and add new lighting fixture L34 and L35, revised lighing layout and update Title 24 calculation. All changes has been clouded as delta 2. Plan check only. Permit covered under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23753	14041-20002-12003	12650 W SANDHILL LANE Unit 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	33.9774	-118.4142	CLOUDED CHANGES. NEW LAYOUT AND NO MONITORING SYSTEM. RESTAMP. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23754	16041-10000-11339	3747 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.01865	-118.35585	PC for energy only to a single story office building. Adding new lighting and power. Totaal sq ft = 6512	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23755	12041-20000-27765	800 S HOPE ST 2nd floor	90017	14	129A209   202	5144020900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.0463	-118.25904	Existing high-rise building, change to lighting, new circuits and receptacles.  Load is 86 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23756	17041-20000-26334	9655 N PINE ORCHARD ST	91331	7	201B161   969	2624013***	(Q)RD5-1-CUGU, RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.24518	-118.40973	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23757	16041-10000-44713	216 N LARCHMONT BLVD #216A	90004	4	138B189   584	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.07531	-118.32344	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A RETAIL SPACE (COSMETICS STORE). TOTAL AFFECTED AREA IS 1000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23758	11041-10000-22016	11878 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	03/15/2012 12:00:00 AM	ADDRESS	34.28617	-118.50151	T-24 lighting plan check for NONSTRUCTURAL INT T.I. TO (E) RESTAURANT.  The permit is for new and relocated luminaires on existing circuits, and to install one new A/C unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23759	18041-10001-44577	5227 N WINDERMERE AVE	90041	14	163-5A221 150	5671019007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM			PC Approved	01/07/2019 12:00:00 AM	ADDRESS	34.14248	-118.21714	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE MODULE LAYOUT AND EQUIPMENT LOCATION UNDER CLOUDED AREA. ____________________NEW ROOFTOP  6 KW AC PV SYSTEM FOR SFD, CONNECTED TO EXISTING 200A PANEL22 MODULES, 1 6KW INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23760	17041-20000-38138	2242 S HOBART BLVD	90018	8	123B193   282	5058018014	[Q]RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.03502	-118.30766	Install 27 kWh energy storage system for SFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23761	15041-20000-02519	3303 W WILSHIRE BLVD #1225	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.06195	-118.29439	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 1435 SQFT. SUITE # 1225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23762	12041-10000-11771	725 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	05/22/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	ALTERATIONS IN EXISTING OFFICE SPACES IN SUITE 3100PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23763	14041-10000-19365	2806 S HALLDALE AVE	90018	8	123B193  1089	5053029008	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.02972	-118.30261	Installation of roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23764	19041-20000-53908	1062 S ALVIRA ST	90035	5	132B173   690	5087013010	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	01/11/2020 12:00:00 AM	ADDRESS	34.05712	-118.37103	PV1.  Install 5.360 kW DC roof mounted PV system.  (16) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23765	15041-10000-10978	300 S GRAND AVE STE 1600	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	Energy plan check for an office T.I  at a high rise building at 16th floor suite-1600. Scope including 3-location at the same floor with new lighting and receptables. Total area is 1140-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23766	19041-10000-50771	2581 E CHAUCER ST BUILDING 5	90065	1	145-5A217 517	5445031***	[Q]CM-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	09/03/2020 12:00:00 AM		Permit Finaled	07/28/2021 12:00:00 AM	PIN	34.0949861	-118.23281575	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A SERVICE OF 400 AMPS, 120/208 V, 3-PHASE 4W. TOTAL AFFECTED AREA: 4658 SQ FTALL 5 BUILDINGS ARE CONNECTED TO 1 SERVICE SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23767	18041-10001-43289	3730 S TULLER AVE	90034	5	117B161  1079	4252001029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.01376	-118.41894	EXPEDITE PER  APPLICANT REQUEST: PLAN CHECK FOR ROOFTOP MOUNTED 13.65 kw DC PV SYSTEM WITH (42) MODULES , (1) AC INVERTER WITH 11.4 KW,  (42) POWER OPTIMIZER P400 WITH 175A CIRCUIT BREAKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23768	08041-20001-23138	8931 W ELLIS AVE	90034	5	123B169  1440	4312011006	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey		YES	2701.00	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM			PC Approved	03/16/2011 12:00:00 AM	ADDRESS	34.02949	-118.38998	revise energy plans emergency lighting existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23769	11041-10001-18014	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	Lighting tracks were changed to Listed Type ; track luminaires remained the same  with  17 W LED lamps; No other changes to the plans in the fieldT.I.  Exising furniture store to be gutted and occupied by a different furnitire store (Ashley Furniture Homestore).  Applicant states that no new load will be added.  Plan check is for energy only on a 34,019 sq ft store using the performance method..NOTE: AT VERIFICATION , ENGINEER INDICATED THAT ALL CIRCUITS SHOWN ON THE PANEL SCHEDULES ARE NEW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23770	13041-10000-15046	12868 W FOOTHILL BLVD	91340	7	219B161   309	2514002***	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	PIN	34.29303815	-118.41556061	PLAN CHECK FOR TITLE 24 ON AN OFFICE TENANT IMPROVEMENT. EMERGENCY LIGHTING IS NOT IN SCOPE OF WORK OR PLAN CHECK. REMINDER: ALL TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23771	14041-10001-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			04/21/2015 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Expired	05/24/2018 12:00:00 AM	ADDRESS	34.04578	-118.23334	This submittal under supplemental for change in design of the original submittal..>>>PLANCHECK FOR POWER AND ENERGY FOR  A  NEW 472 Unit Type III  Apt. Building Over Type I Commerciasl Use & Garage Structure. TITLE 24 ENERGY SQFT NOT INCLUDED IN FEES. FEES ARE BASED APPLICANT.<<<<<	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23772	12041-20000-17177	10 W UNIVERSAL CITY PZ	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM			No Progress	07/24/2012 12:00:00 AM				T.I. to a high rise bulding on the entire 28th floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-17178	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23773	17041-10000-13405	1129 S SAN PEDRO ST	90015	14	124-5A211 260	5145025011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.03457	-118.25289	Plan check for power and energy.  T.I. and change of use in building 13 and 14 to commercial kitchen and event space.  New 600 amp service and distribution system.  Total area = 25,260 sq. ft.     Building permit #16016-10000-30193	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23774	16041-20000-26478	11022 BENJAMIN LANE	91344	12	210B137   947		(T)(Q)RD6-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	PIN	34.2712139	-118.48754573	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23775	19041-20000-39330	3575 N GRIFFITH PARK BLVD	90027	4	154-5A203 189	5592004012	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.11734	-118.27405	PV1. INSTALL 8.7 KW DC / 8.0 KW AC PV SYSTEM WITH (26) MODULES/OPTIMIZERS AND (1) INVERTER(SE7600H-US).NOTE: INSPECTION FEE HAS BEEN PAID UNDER ONLINE PERMIT 19041-90000-34034	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23776	17041-10001-43082	16521 S ESTRELLA AVE	90247	15	069B201   368	6121005004	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	33.88104	-118.28567	**Zero fee per California Senate Bill 1222**Revision to approved set: reduced modules qty to 17, and modules model# to SPR-X21-345-D-AC. System now becomes 5.9 kW AC.  This is plan cehck only, permit is covered under master plan.<<PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.03KWdc / 6.72KWac.(21)AC MODULES-SUNPOWER SPR-X21-335-BLK-D-AC>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23777	18041-10000-05321	1050 W ARROYO ST	91340	7	216B161   160	2514019014	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	PIN	34.2881352	-118.41898074	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23778	18041-10000-18748	445 S BUNDY DR	90049	11	132B141   920	4404008020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.05452	-118.47558	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (42) MODULES (42) POWER OPTIMIZERS AND (1) 11.4 INVERTER. TOTAL SYSTEM SIZE IS 13.65KWDC/11.4KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23779	14041-10000-27782	11423 W VANOWEN ST	91605	2	183B169   471	2320003025	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.19416	-118.38009	PV 2 system. Roof mounted. Negatively grounded, central inverter system.1,078 modules, 1 inverter, and i AC disconnect for a 269,500 kW systemPermit fee waived due to Senate Bill SB-1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23780	19041-10000-11255	701 S HILL ST	90014	14	129A209   229	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	01/28/2022 12:00:00 AM	ADDRESS	34.04582	-118.25475	PC for FA, 1 Panel and 512 Devices. 17 story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23781	18041-20000-46097	22020 W VENTURA BLVD	91364	3	171B101   164	2169002033	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.01	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.1683	-118.60672	Plan check for Title 24 only in existing space convert office to restaurant Total area: 1623 sq ft. B#18016-30000-30226	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23782	13041-10002-09313	19500 W PLUMMER ST SUITE G3	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	[[[[[[[[[SUPPLEMENTAL PLAN CHECK FOR 13041-10000-09313. DELTA 2 CHANGES ONLY.  FAULT CARE IN DELTA-2 IS RECALCULATED.  CHANGES ARE FOR THE INCLUSIONS OF FAULT CALC AND LOAD SUMMARY TO REFLECT ACTUAL WORK, CIVIL ENGINEER PERMITTED TO SIGN FOR THE PLAN PER 93.0206(a) 10/10/13]]]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23783	16041-10000-14565	1616 W 209TH ST	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	PV1 INSTALL 2.295 KW DC ROOF-MOUNTED SOLAR ARRAY ON A MULTI FAMILY HOUSE.(9) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23784	13041-20000-30853	10390 W SANTA MONICA BLVD SUITE 150	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.05734	-118.42365	PC FOR T24 ENERGY ONLY. TOTAL AREA 7060 SQ FT. NEW LIGIHTING. OFFICES AND TRAINING ROOMS. WORK DONE IN SUITE 150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23785	17041-10000-04321	518 E AVENUE 39	90031	1	144A225   403	5207018010	[Q]R1-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Issued	02/09/2017 12:00:00 AM	ADDRESS	34.08777	-118.2052	Istallation of new PV1 roof mounted system. Central inverter is rated at 7.6 KW, 22 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23786	10041-10001-08378	4433 S ALAMEDA ST # 4B	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM			PC Approved	07/20/2010 12:00:00 AM	ADDRESS	34.00295	-118.23924	Develope a tenant space  into a juice-barplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23787	19041-10000-22136	735 S FIGUEROA ST #308	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.04878	-118.26079	T-24 PLAN CHECK FOR A TI OF STARBUCKS COFFEE SHOP. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, REEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1287 SQ.FTB#19016-10000-17069	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23788	13041-10000-17538	4720 W JANET PL	90041	14	160-5A219 134	5685002024	RE20-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.13458	-118.22225	PV1 7.68KW XFRMLESS. 1 STORY. NONSTD. ROOFMOUNT. [ (2) INV: POWERONE PV-3.6-OUT-S-US ] [ (32) MOD: TRINA {TSM-240PA05} ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23789	16041-20000-15701	18421 W ALGIERS ST	91326	12	213B125   633	2870012011	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.27658	-118.53544	Plan check for an addition of a PV1 roof-mounted PV system. PV addition system size is 3 kWac and consists of (1) inverter, (11) modules, and (1) load center. Total system size is 6.8 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23790	12041-10000-14306	6374 W SUNSET BLVD	90028	13	147A187   584	5546015047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.09768	-118.32839	COMMERCIAL SPACE IS SUB-DIVIDED INTO 4 VACANT TENANT SPACES-INSTALLATION IN 3 OF THE SPACES ARE FC AND CU UNITS AND PANELBOARDS AND 75KVA TRANSFORMER. ADDED EGRESS LIGHTING IN CORRIDOR OUTSIDE THE TENANT SPACES.  FULL PLAN CHKTENANTS A3;A4;A5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23791	14041-10000-21391	14402 W CALIFA ST #2	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23792	16041-20000-18557	822 E 75TH ST	90001	9	102B209   346	6023014006	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.01	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.97193	-118.25998	Plan check for PV roof mounted system in house duplex single structure. The system connectted to 2 meters splite bus 200A each  on single structure. System size: 14kW with 44 AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23793	15041-10000-35604	1239 N GORDON ST	90038	13	144B189   198	5534013006	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.09364	-118.32022	PV1, INSTALL 6.095 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(23) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23794	15041-20000-14436	22725 W DOLOROSA ST	91367	3	174B097   769	2040019022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.17024	-118.62199	Plan check for PV roof monted  6.8kWac system with 24 modules and 2 inverter(3.0kW and 3.8kW) and a load center connected to 200A panel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23795	13041-10000-12865	6230 N SEPULVEDA BLVD	91411	6	177B145   241	2242010024	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.18388	-118.46592	PLAN CHECK FOR TITLE 24 FOR ENTERPRISE RENT-A-CAR.  1334 SQUARE FEET. INDOOR, EMERGENCY AND FACADE LIGHTING. 200A SERVICE, LOAD < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23796	17041-10000-33530	8605 W PICO BLVD	90035	5	132B173  1217	4332023048	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05401	-118.37879	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23797	19041-20000-50149	7018 N ALABAMA AVE	91303	3	183B105   605	2138013009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			12/05/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.1979	-118.59888	INSTALL (69) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23798	16041-10000-20515	1557 E 53RD ST	90011	9	108B213   132	5105002029	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	33.99493	-118.24584	PV1 SYSTEM WITH 3.8KW AC CENTRAL INVERTER AND 12 SOLAR MODULES. Total system size is 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23799	12041-10000-28654	2926 E OLYMPIC BLVD	90023	14	120A221   168	5170025005	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.02195	-118.21487	TI FOR EXISTING WAREHOUSE. 1 STORY. 9014SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23800	14041-10000-13687	11723 W BARRINGTON CT	90049	11	135B145   628	4401007008	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.06437	-118.46984	PC for power and energy, T.I. interior remodeling for existing resturant. Total area 1618 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23801	13041-10001-13905	4075 S FIGUEROA ST	90037	9	115-5A201 229	5019023030	C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Apartment			08/21/2013 12:00:00 AM			Corrections Issued	08/21/2013 12:00:00 AM	ADDRESS	34.0098	-118.28296	[[[[[[[SUPPLEMENTAL APP, CHANGES TO APPROVED SET OF PLANS]]]]]]]]]]]]]]]]TITLE 24 AND EMERGENCY LIGHTING, TOOK OLD LIGHTS AND  REPLACED WITH NEW LIGHTS, THIS IS COMMON AREA TO APARTMENT BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23802	18041-20000-02215	12121 W BLUFF CREEK DR Suite 1	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Issued	02/06/2018 12:00:00 AM	ADDRESS	33.97874	-118.40463	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement in a kitchen. Total lighting area = 2,039 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23803	11041-10001-09172	5072 S SLAUSON AVE	90230	11	108B161  1180	4217029903	OS-1XL, R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM			PC Approved	11/17/2011 12:00:00 AM	ADDRESS	33.99368	-118.40672	Delta 2 modification as shown on pages E101 and E200 to previously approved set of  plans.  The modification is to install exterior basket ball court lights on only one side of the basket ball court.  Permit is to be issued on application number  11041-10000-09172.  Plan check is for T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23804	13041-10000-08395	3425 S MOTOR AVE 1-115	90034	5	120B161   346	4314017004	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			04/02/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.02711	-118.40945	New fire alarm system for a 5-story apt bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23805	17041-20000-44064	20441 W KESWICK ST	91306	3	186B109    40	2114001031	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.20979	-118.57883	pv1install roof mounted pv system sized 12kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23806	17041-10000-37838	1331 W 253RD ST	90710	15	036B197   393	7410026900	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	33.79484	-118.30004	TITLE 24 ONLY, RELACE OUTDOOR EXISTNG FIXURES WITH LED FIXURES, TOTAL SQUARE FOOTAGE 11950 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23807	19041-20000-34234	9715 N ETIWANDA AVE	91325	12	201B125   279	2764004007	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.24708	-118.53187	Plan check for PV roof mounted system, System size: 9.24KW with 28 PV Modules and 2 inverters(5.2KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23808	12041-10000-24325	15211 W SHERMAN WAY 1-99	91405	6	183B145   784	2221019117	R1-1, R3-1, R3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			10/11/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.20144	-118.46442	new fire alarm for , 6 story and roof apartment , new panels and 280 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23809	16041-20000-25539	16001 W LEMARSH ST	91343	12	204B141   508	2669005001	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Expired	08/28/2018 12:00:00 AM	ADDRESS	34.25565	-118.48058	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23810	19041-10000-01063	6343 N VINELAND AVE	91606	2	180B173   943	2336020037	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.18607	-118.37052	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23811	13041-10000-24513	4762 N LANKERSHIM BLVD	91602	2	168B173   512	2421015001	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.15726	-118.36961	PLAN CHECK AND PERMIT FOR TITLE 24 AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23812	18041-20002-35025	5232 E BALTIMORE ST	90042	1	154-5A225 270	5478017007	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.11776	-118.20222	04-10-2019 Changes to an approved set of plan, changes include remove battery and reduction of PV system size, PV system size: 3.6KW DC, 3.6KW AC with 10 PV Modules.Permit fees $0.00 due to california senate bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23813	19041-10000-02073	4405 S AVALON BLVD	90011	9	112-5A207  82	5109015036	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2285.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.00363	-118.26549	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23814	14041-20001-17533	11593 W KLING ST	91602	2	168B169   663	2354016040	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.1559	-118.38525	Expedited plan check per applicant.  PV1.  Install 8.32 kW roof-mounted, utility-interactive PV system.  Transformerless inverter standard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23815	14041-20000-24533	3000 N BENEDICT CANYON DR	90210	5	156B153    76	4382002008	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.12642	-118.43613	PROPOSED NEW 2-STORY SFD W/ ATTACHED RECREATION ROOM OVER 4-CAR GARAGE.  BUILDING PERMIT FILED PRIOR TO JULY 1, 2014 - 2008 BUILDING ENERGY EFFICIENCY STANDARDS.PERMIT ISSED UNDER ORIGINAL ORIGINAL BUILDING/ COMBO PERMIT. ELECTRICAL PERMIT FEES HAVE BEEN COLLECTED. NO ADDITIONAL FEES REQUIRED. THIS APPLICATION IS PLAN CHECK ONLY. NO NEW PERMIT TO BE ISSUED UNDER THIS APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23816	16041-20000-29560	14804 W RAYMER ST	91405	6	189B149   535	2210025033	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.2127	-118.45556	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OUTDOOR LIGHTING FOR BUS PARKING LOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23817	18041-10000-38132	700 S FLOWER ST G200	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR RESTAURANT TI (OCC LOAD =116) FOR POWER AND ENERGY.  SCOPE INCLUDES NEW DISTRIBUITION AT480/277, PANELS ,CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 2493.B#18016-10000-15953	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23818	19041-20000-30340	7810 N TOPANGA CANYON BLVD	91304	3	189B101   648	2110012054	(Q)RD1.5-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.06	Electrical	Electrical	Apartment			08/05/2019 12:00:00 AM			PC Info Complete	02/04/2020 12:00:00 AM	ADDRESS	34.21218	-118.60573	TI REMODEL OF EXISTING APARTMENT BUILDING. UPGRADE (34) UNIT PANELS TO 100 AMPS AND ADDING SOME NEW LOADS TO UNIT PANELS.PHASE 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23819	17041-10000-08543	888 S FIGUEROA ST #2160	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.0465	-118.26225	Plan check for Title 24 only in existing high rise T.I. office space. Total area: 2826 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23820	14041-20000-16303	16742 W MARILLA ST	91343	12	201B137   485	2686006003	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.24766	-118.49732	pv1 single family dwelling. total system size 3.8kw ac using transformerless inverter. nonstandard plan. using power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23821	14041-20001-35856	10120 N WOODLEY AVE	91343	12	204B141   700	2669007004	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM			PC Approved	01/10/2015 12:00:00 AM	ADDRESS	34.25451	-118.48468	Expedited per customer request.PV1. Install roof mounted PV system sized 6 KW. Interconnected with main service pannel.(18) Sunpower 327W Modules(1) PVI-6000-TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23822	11041-10000-17995	1111 S HOPE ST Ste 110	90015	14	127-5A207 262	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	34.0422	-118.26337	T.I.  Modification to an approved set of plan (PCIS # 10041-10000-13177).  Modifications are enough where a new plan check is needed.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23823	18041-30000-28698	318 S LINCOLN BLVD 225	90291	11	111B145   642	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.00111	-118.46697	TI IN AN EXISTING OFFICE AREA ON 2ND FLOORT-24 ENERGY ONLY. TOTAL AREA: 2,455 SQ.FT(This is a re-plan check for a lost plan under application# 18041-10000-26130)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23824	12041-10000-19878	2520 W 6TH ST 4TH FLR	90057	1	133-5A203  50	5141006015	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	09/05/2012 12:00:00 AM		Permit Expired	10/06/2014 12:00:00 AM	ADDRESS	34.06182	-118.28033	TENANT IMPROVEMENT OF EXISTING OFFICE ON 4TH FLOOR (10918 sq ft) :. NO CHANGE IN FLOOR AREA.   Change to lighting and receptacles, Load is less than 200Amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23825	15041-10000-12534	5555 W HOLLYWOOD BLVD	90028	13	148-5A193 134	5544003049	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.1019	-118.31132	FIRST TIME TENANT IN RETAIL SPACEPLAN CHK IS FOR POWER AND TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23826	19041-10000-14142	2681 N CORDELIA ROAD	90049	11	141B133    63	4492025024	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/04/2019 12:00:00 AM	ADDRESS	34.08411	-118.5081	[e-plan] REVISION TO EXISTING PERMIT:  18041-10001-15294DELTA 1 - PER LADWP ESR-- DC DISCONNECT FOR BATTERYADDED. SINGLE LINE UPDATED TO SHOW FEEDS FROMUTILITY AND STOREDGE INVERTER TO CRITICAL LOADCENTER WITH MECHANICAL INTERLOCK DEVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23827	16041-10000-24032	14319 W GREENLEAF ST	91423	4	165B153   585	2266005025	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.14778	-118.44542	PERMIT FEE IS $0.00 DUE TO SENATE BILL 1222.PV1 INSTALL 21.7 KW D C ROO-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(70)MODULES; WINAICO WSP310-M6(2) INVERTERS : SOLAREDGE 7.6 AND 11.4 KW(70) SOLAREDGE POWER OPTIMIZER P320INTERCONNECTING THROUGH THE LOAD/MAIN SERVICE PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23828	16041-10000-37492	200 WORLD WAY T2 LEVEL 4	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	T-24, PC FOR ENERGY ONLY. TI FOR EXISTING FACILITIES FOR TERMINAL 2 OF LAX. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A LOUNGE AND OFFICE SPACE. TOTAL AFFECTED AREA IS 9336 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23829	17041-10000-16088	20127 W SATICOY ST	91306	3	186B113   120	2114004045	(Q)C1.5-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.20848	-118.57207	TI FOR BEAUTY SALON. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23830	12041-20000-11422	1229 N HIGHLAND AVE	90038	4	144B185   292	5532006029	C2-1D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.09336	-118.33882	Upgrade to 800 A service  with new switchboard.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23831	19041-10000-26363	13132 W RAYMER ST	91605	2	186B157   317	2327001045	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.20556	-118.41929	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23832	18041-10000-39888	1920 S MORAY AVE	90732	15	012B193   886	7562013011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	Yes	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	33.72702	-118.31248	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH POWER OPTIMIZERS. (38)MODULES AND (1) 10KW INVERTER. TOTAL SYSTEM SIZE IS 10KWAC AND 11.4 KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23833	14041-10000-07841	13420 W VAN NUYS BLVD	91331	7	207B157   704	2620007005	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.26363	-118.42505	New fire alarm system - new EST I064GD FACP coordinating 38 devices - in a 3-story commercial office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23834	18041-20000-13576	2131 N ROSCOMARE ROAD	90077	5	150B145    70	4377013009	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Issued	04/13/2018 12:00:00 AM	ADDRESS	34.10969	-118.46371	Plan check for PV roof mounted system. System size: 13.23kWac with 46 modules and 2 inverters(6.6kW) connected to MAP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23835	16041-10000-23881	1440 W OLYMPIC BLVD	90015	1	129A205   180	5137013010	C2-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.04817	-118.2724	PC FOR ENERGY. CHANGE OF USE FROM RETAIL TO OFFICE (NO CHANGE IN PARKING -- LA STATE ENTERPRISE ZONE); TOTAL AREA 4153 SQ FT.B#16016-20000-11969	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23836	13041-10000-27140	740 E BROOKS AVE	90291	11	111B145  1292	4239013027	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	33.99737	-118.46485	PV1.  Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel.  1 transformerless inverter: Power-One PVI-3000-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23837	17041-30000-02404	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.01871	-118.28174	Title 24 plan check.  T.I. to existing restaraunt space.  Total area = 1,670 sq. ft.Building permit #16016-20000-24567	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23838	19041-20001-44173	7435 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM			PC Approved	04/29/2020 12:00:00 AM	ADDRESS	34.20582	-118.48615	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23839	15041-10000-17462	8500 W BEVERLY BLVD Space #667	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a retail (space #667) T.I; Scope includes new lighting, equipment, and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23840	15041-10000-25408	20255 W HARTLAND ST	91306	3	183B113   781	2135036015	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.19481	-118.57503	PV1 PC FOR ROOF MOUNTED SOLAR SYSTEM AT RESIDENTIAL SITE. (2)INVERTERS: POWERONE PV1-5000-OUTD-US-A & POWER ONE PV1-6000-OUTD-US-A. (32) MODULES : SPR327NE-WHT-D	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23841	19041-20001-37915	19951 W VENTURA BLVD	91364	3	174B113   382	2164001018	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.17225	-118.56772	Revision to approved set of plans.  Change of interconnection detail to line side tap. (((PV PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS27.06 KW DC/30.24KW AC. SCOPE OF WORK CONSISTS OF (82) PV MODULES WITH (42) MICROINVERTERS AND A NEW 200A PANEL)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23842	17041-10000-18839	2920 S SPAULDING AVE	90016	10	120B173   102	5048014030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.02855	-118.36993	PC for a PV1 roof mounted solar system for a single family home. Central inverter is rated at 5.0 KW, 21 solar modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23843	13041-10001-25289	8521 N HASKELL AVE	91343	12	192B141   199	2673010028	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.22525	-118.4766	[][][] EXPEDITE PER APPLICANT REQUEST[][][][]PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 13KW DC ON NON-STANDARD PLAN IN A 2-STORY HOME. LOAD CENTER & COMBINER BOX IS USED. (52) TRINA SOLAR #TSM-250(2) POWER-ONE  #PVI-5000-OUTD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23844	14041-10000-34538	4354 N TEESDALE AVE	91604	2	165B161   332	2375003044	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.14998	-118.40825	NEW FIRE ALARM SYSTEM. 80 DEVICES , ONE CONTROL PANEL. 16 UNITS APARTMENT, 4 STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23845	18041-20000-43039	7236 N EASTHAVEN LANE	91307	12	186B089   712	2027022026	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.20264	-118.64782	PV1.  Install 9.4 kW AC roof mounted grid tied PV system with centerfed panel connection.  (31) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23846	17041-10000-41092	5503 S FIGUEROA ST	90037	9	108B201   796	5001021032	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	33.99219	-118.28294	REPLACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23847	19041-20000-48463	18000 W DEVONSHIRE ST 2nd Floor	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.25698	-118.52508	Power and lighting for TI.  Plan check for energy.  East Wing Galley.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23848	10041-20000-10055	14444 W TITUS ST	91402	6	192B149   534	2212003011	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM			PC Info Complete	11/29/2010 12:00:00 AM	ADDRESS	34.21966	-118.44792	Plan check for new 600 A service, switchboard, and new feeders (disconnect from existing service panels).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23849	17041-20000-20392	601 N PERUGIA WAY	90077	5	141B149   226	4362003013	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2017 12:00:00 AM			PC Approved	03/15/2019 12:00:00 AM	ADDRESS	34.08032	-118.44886	New 3-story SFD with 800A 240/120V 1ph-3w service.  Plan check for power only.  BUILDING PERMIT # 16010-30000-05115	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23850	14041-10000-02648	3510 W GARDEN AVE	90039	13	154-5A207 347	5437007006	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.11673	-118.26051	PV1, Install 2.75 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel.(1) Transformerless inverter: POWER-ONE AURORA  PVI-3.0-OUTD-S-US. (11) Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23851	13041-10000-31355	1010 N MANSFIELD AVE	90038	4	144B181   564	5532028011	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.08939	-118.34026	PLAN CHECK AND PERMIT FOR A NEW FIRE ALARM SYSTEM. 1 STORY WAREHOUSE.. 1 PANEL 27 DEVICES. SINGLE STORY, BUILDING IS FULLY SPRINKLERED SYSTEM. APPROXIMATELY 9000 SQ FT OF AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23852	16041-30001-10005	1641 S CRESCENT PL	90291	11	108B145  1270	4241013013	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	33.99104	-118.4615	Expedite fees only.        Installation of new roof mounted solar PV array on existing duplex.  Total system size = 3 kWac.  Microinverter system.  Address was not available for online permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23853	19041-10001-06985	1475 S ROBERTSON BLVD	90035	5	129B169   274	4305014078	C2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.05254	-118.3842	"Change to approved set by adding new ckts, equipment, modifying lighting and power floor plan. All changes under delta-3 only.Original plan checker: Dian(((POWER AND ENERGY PC FOR A TI FOR A CHANGE OF USE FROM ""M"" RETAIL OCCUPANCYTO ""E"" PRIVATE PRE-SCHOOL. SCOPE INCLUDES NEW 600 SERVICE, RECEPTACLES, LIGHTING AND EQUIPMENT. TOTAL AFFECTED AREA IS 10,586 SQ.FTB# 19016-10000-054355/16/19: Modification for 30Day meter reading is filed )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23854	17041-20000-07264	2006 N KENMORE AVE	90027	4	150B197   436	5589015004	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.10816	-118.29703	pv1install roof mounted pv system (acm) sized 6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23855	11041-20000-08203	10760 N VARIEL AVE	91311	12	207B105   150	2706004001	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	08/12/2011 12:00:00 AM	ADDRESS	34.26628	-118.59279	Roof mounted P.V. with 22KW system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23856	19041-10000-28127	573 S BOYLE AVE	90033	14	126A221     2	5174001015	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	07/24/2020 12:00:00 AM		Permit Finaled	01/20/2022 12:00:00 AM	ADDRESS	34.04034	-118.21997	POWER AND ENERGY PC FOR NEW CONSTRUCTION OF A TWO STORY, 14,267 SF OF NON-AMULATORY HOME FOR THE AGED WITH SPECIAL CARE AND STATE APPROVAL.  THE BLDG CONTAINS MULTI-PURPOSE ROOMS AND NURSE STATION. SERVICE SIZE IS 800A, 120/208V, 3PH/ 4WIRE. TOTAL SQ. FT. 18620.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23857	17041-30001-39882	10727 W WILSHIRE BLVD 1-109	90024	5	132B153   123	4360033***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			Corrections Issued	04/23/2018 12:00:00 AM	ADDRESS	34.06081	-118.43692	03-27-2018 Changes to an approved set of plan. Changes include additional of 20 meters for future EV Chargers and upgrade distribution from 600A to 1000A sections. Changes has been clouded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23858	13041-10000-04286	380 W WORLD WAY Space T17	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Tenant improvement for retail shop. Power and lighting. Submittal per customer request. Space T17	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23859	19041-10000-23890	19191 S VERMONT AVE STE 840	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLAN CHECK FOR ENERGY ONLY FOR - Interior, non-structural tenant improvement to (E) office suite 840 (2719 SF). No change in use or occupancy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23860	19041-20000-34337	427 S MARIPOSA AVE	90020	10	135B197   620	5502015011	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2119.10	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	10/09/2020 12:00:00 AM		Issued	10/09/2020 12:00:00 AM	ADDRESS	34.06632	-118.29938	POWER AND ENERGY PLAN CHECK FOR UPGRADE OF A EXISTING 5-STORY 55-UNIT APARTMENT BUILDING. UPGRADING THE SERVICE TO 800A AND UPGRADING THE ENTIRE ELECTRICAL DISTRIBUTION SYSTEM AND LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23861	15041-20002-17225	14857 W BESSEMER ST	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM			Corrections Issued	08/11/2015 12:00:00 AM	ADDRESS	34.18089	-118.45716	PLAN CHECK FOR CONNECTION TO 600A SERIVCE PART OF 3 UNIT SUBDIVISION. THIS PERMIT SHALL BE FOR THIS FUTURE TENANT SUBPANEL AND LOAD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23862	16041-20000-36717	13133 W BLOOMFIELD ST	91423	4	165B157   430	2375001068	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.14943	-118.41929	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (32) AC modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23863	11041-20000-21961	514 W 7TH ST	90014	14	129A209   176	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.04675	-118.25614	Plan check T24 Energy/Emergency for existing restaurant TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23864	16041-20000-01182	6742 N WINNETKA AVE	91306	3	180B113    96	2134013016	[Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.19321	-118.57074	TI to an existing commercial building (medical office). Plan check for power and energy.  Adding new lighting including emergency. New 400A service. Total sqft. 2302.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23865	16041-10000-37944	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 203	5161024014	[Q]C2-4D-O, [Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Issued	10/26/2016 12:00:00 AM	ADDRESS	34.05007	-118.2433	PC FOR POWER. SCOPE INCLUDES Installation of 800A SWITCH BOARD AND WIRING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23866	19041-10000-14568	400 S HOPE ST 300	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.05199	-118.25366	Energy plan check for restroom remodel located in the 3rd floor of a high rise building. Scope includes new lighting and equipment with total area of 879-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23867	10041-10001-10217	8180 W MELROSE AVE	90048	5	141B173   468	5528011036	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	PIN	34.0834491	-118.36781879	Change the priviously approved plan. Plan check for T24.  (((((((((((T-24 lighting plan check for remodeled tenant space.)))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23868	19041-10000-50127	6420 W WILSHIRE BLVD #1400	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.06365	-118.36922	TI IN AN EXISTING OFFICE AREA. INSTALLING NEW LIGHTS. T24 ENERGY ONLY. AFFECTED AREA: 3,897 SFT.BLDG PERMIT: 19016-10000-37730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23869	17041-20000-08493	539 S BEVERLY GLEN BLVD	90024	5	138B157    92	4360025044	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.07229	-118.4319	Plan check for power only. Install new 600A service for SFD. New wiring and distribution for additions (grage, rec room/theater, master's bedroom, etc). Electrical permit fees already collected under building combo permits under application #s 12010-20000-02007, 12014-20000-01833, 12010-20000-01128.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23870	17041-20000-24603	7630 N VINELAND AVE	91352	2	186B173   151	2409016051	(Q)C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.20913	-118.36999	Plan check for energy only. TI to gym, new lighting in locker rooms and bathroom. 371sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23871	14041-20001-01891	6923 ESTEPA DR	91042	7	198B201   107	2572031019	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/07/2014 12:00:00 AM	PIN	34.24176892	-118.28290574	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 24 MODULES TRANSFORMERLESS INVERTER NONSTNADARD PLAN WITH POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23872	13041-10000-31542	5734 N TUJUNGA AVE	91601	2	174B173   462	2337036001	C2-1, P-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.175	-118.37885	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23873	19041-10000-01092	12317 W BRANFORD ST	91352	7	201B165    65	2537015047	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Issued	01/10/2019 12:00:00 AM	ADDRESS	34.24969	-118.40146	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23874	15041-10001-09058	2510 W TEMPLE ST	90026	13	138A205   190	5157008012	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.07192	-118.27348	DELTA (1) CHANGES TO THE APPROVED MEHANE MITIGATION SYSTEM FOR 1 ADDITIONAL SENSER. 12 SENSORS AND ONE CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23875	19041-20000-34091	10250 W SANTA MONICA BLVD kiosk 9210	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Issued	09/04/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for power and energy for First Time Tenant Kiosk restaurant with outdoor dinning. Total area: 250 sq ft. B#19016-10000-26113	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23876	16041-10000-23074	5550 S INGLEWOOD BLVD	90230	11	105B165   410	4220016900	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	10/24/2018 12:00:00 AM		Issued	10/24/2018 12:00:00 AM	ADDRESS	33.98441	-118.40559	PC for power, replacement of existing standby generator and automatic transfer switch, variable frequency drives, motor-operated valves, pump motors, and  sump pump. Also, replacing lighting fixtures for generator electrical room. Total affected area is 1499 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23877	18041-10000-37133	152 N RAMPART BLVD	90026	13	138A203   446	5157001009	R3-1	Central	Westlake	Echo Park		2086.20	Electrical	Electrical	Apartment			09/28/2018 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM	ADDRESS	34.07074	-118.27579	Full plan check for a new 2-STORY 9-UNIT APARTMENT OVER 1 LEVEL PARKING GARAGE. Scope includes (1) 800-amp service with a total T-24 area of 8458-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23878	14041-20000-05289	5454 N NORWICH AVE	91411	4	174B145   717	2250013036	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.17011	-118.46054	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23879	14041-10002-11744	1616 N LA BREA AVE	90028	13	147B181   377	5548012046	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			12/11/2015 12:00:00 AM			PC Approved	12/11/2015 12:00:00 AM	ADDRESS	34.1002	-118.34456	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE RENAME OF PENTHOUSE UNITS. ALSO CHANGING FROM FULLY RATED SYSTEM TO SERIES RATED SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23880	19041-10000-01147	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC for t-24 only . remodel of alaska airline mezzanine lounge.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23881	11041-20000-26567	5757 N MURIETTA AVE	91401	2	174B153   307	2246017006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.17556	-118.43898	New 1.38 KW roof punted PV sytem for a single family residence.  Applicant is using the M215 microinverters.  A variance has been filed to use the microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23882	16041-10000-42032	725 S FIGUEROA ST ste 175	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR OFFICE TI. CHECKING NEW LIGHTING. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23883	12041-20000-13386	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	33.9451	-118.37436	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23884	12041-10000-29827	738 E 12TH ST	90021	9	123A211    36	5132012035	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.03297	-118.25214	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. SCOPE OF WORK IS 2137 SQUARE FEET. TENANT IMPROVEMENT OF A RETAIL STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23885	12041-10000-27973	3232 S PHILO ST	90064	5	123B161   726	4316019008	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.03242	-118.40768	3.45 kw roof mounted PV for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23886	12041-10000-30516	6600 N TOPANGA CANYON BLVD #1082D	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR POWER AND TITLE 24 ENERGY. CALIFORNIA PIZZA KITCHEN (SPACE #1082D). CHANGE OF USE FROM RETAIL TO RESTAURANT. PLACE OF ASSEMBLY 160 OCCUPANTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23887	18041-20000-31156	8524 N WILBUR AVE	91324	12	192B121   213	2785011005	R1-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.22529	-118.54464	PV1.  Install 14.7 kW DC/15.2 kW AC roof mounted grid tied PV system.  Derating of main breaker to 175A.  (42) modules with 11.4 and 3.8 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23888	17041-20001-02410	12860 W FILMORE ST	91331	7	213B161   865	2533029075	(T)(Q)R2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.27778	-118.41301	expedite per appliacntpv1install roof mounted pv system sized 3kw interconnectedw ith msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23889	15041-10000-31641	210 S OCEAN FRONT WALK	90291	11	109-5A141 164	4286030903	OS-1XL-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	07/02/2020 12:00:00 AM	ADDRESS	33.99485	-118.48086	PC FOR HAZARDOUS LOCATION IN PUBLIC RESTROOMS(VENIECE BEACH). METHEANE BUFFER ZONE. T24 APPROVED ON APP#  15041-10000-11131.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23890	15041-20002-26423	13630 W SATICOY ST	91402	6	186B157   140	2214025004	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM			PC Info Complete	10/31/2016 12:00:00 AM	ADDRESS	34.20928	-118.42941	[10/12/16 CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. DELTA 4 CHANGES ONLY. RELOCATION OF EQUIPMENT AND (2) NEW DISTRIBUTION BOARDS.  CHANGE OF ENGINEER ON DRAWINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23891	18041-10000-36196	14303 W FRIAR ST	91401	6	180B153  1178	2240012012	[Q]R3-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.18578	-118.44453	PLAN CHECK FOR POWER AND ENERGY FOR (N) 4 STORY, 30(10 TYPICAL) UNIT APARTMENT BUILDING AFFORDABLE HOUSING PROJECT - MAIN SERVICE IS RATED AT 120/208V-1600A SERVICE. TOTAL AFFECTED AREA =  17491 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23892	15041-10000-31643	2121 S AVENUE OF THE STARS ste 1630	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.05554	-118.41342	T-24. Tenant Improvement to a high rise commercial building (25 floors). Scope of work is being done on 16th floor only. Existing service and equipment. Installing new lighting and receptacles. PC for energy only. Sq ft = 5498.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23893	18041-20003-29197	3499 N CAHUENGA BLVD	90068	4	159B177   319	2425024011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	34.13268	-118.35578	Revisions to approved set of plans - correction of Title 24 form declarations to reflect scope of work.  (((Title 24 Part 6 plan check for commercial office lighting per inspection correction notice.))) (((Change in legal: change in address and legal from 3449 N. CAHUENGA BLVD to 3499 N. CAHUENGA BLVD, date: 09/04/2018)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23894	19041-10000-36442	16855 W DEVONSHIRE ST	91344	12	204B133   185	2684007020	C4-1VL, QC4-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	02/05/2021 12:00:00 AM		Permit Finaled	04/09/2021 12:00:00 AM	ADDRESS	34.25768	-118.50006	NEW LIGHTING SYSTEM IN LOBBY OF A TIRE STORE AND FOR AN OUTSIDE CANOPYPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23895	14041-20000-04456	1550 N OLD OAK ROAD	90049	11	132B137   203	4425025002	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.05997	-118.4963	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 3 STRINGS/ INVERTER. SERVICE INTERCONNECTION TO 400A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23896	19041-10000-01743	16730 W CHATSWORTH ST	91344	12	207B137   440	2684002901	OS-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	02/28/2023 12:00:00 AM		Issued	02/28/2023 12:00:00 AM	ADDRESS	34.26459	-118.49686	Energy plan check for a renovation and and addition to an aquatic facility. Scope includes new lighting and equipment with a total area of 8,453 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23897	13041-10000-11319	11678 W SAN VICENTE BLVD	90049	11	129B145    35	4265006007	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	34.05361	-118.46459	PLAN CHECK FOR TITLE 24 FOR A TENANT IMPROVEMENT OF AN EXISTING RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23898	12041-10000-22574	6882 S ARIZONA AVE	90045	11	102B165   127	4110001028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Expired	11/18/2014 12:00:00 AM	ADDRESS	33.97776	-118.39577	NEW 13.8 KW ROOF MOUNTED PV FOR A SINGLE FAMILY.   (New service & panels are under separate permit)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23899	11041-20000-23211	14006 W RIVERSIDE DR #FC-12	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM	11/15/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check T24 Energy/Emergency lighting for LIDS retail TI. #FC-12. Permit to include new branch ckts and relocate existing transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23900	11041-10000-15224	4650 W FRANKLIN AVE	90027	4	150B197   911	5590015024	C4-1D	Central	Hollywood	Greater Griffith Park		1891.01	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			Corrections Issued	07/20/2011 12:00:00 AM	ADDRESS	34.10527	-118.29124	T.I.  Existing 7-11 replacing light fixtures.  T-24 plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23901	10041-10000-05208	11502 S CENTRAL AVE	90059	15	084B209    20	6070016007	C2-1VL	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	03/25/2010 12:00:00 AM		Permit Expired	08/30/2012 12:00:00 AM	ADDRESS	33.93017	-118.25407	PLAN CHECK T-24 ENERGY FOR HAND CAR WASH FACILITY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23902	11041-20002-01318	818-838 E 29TH ST	90011	9	118-5A207 333	5128015052	(T)(Q)R3-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Apartment			04/01/2011 12:00:00 AM			PC Approved	04/01/2011 12:00:00 AM	ADDRESS	34.01762	-118.26081	Plan check for revision to New fire alarm system plan check. Delta 1 change to indicate FPLR type conductor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23903	11041-10003-12353	620 W 2ND ST PLAZA	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.0545	-118.25027	((( CHANGES TO APPROVED SET OF PLANS: NEW LOADS WERE ADDED TO THE SERVICE :277/480v SWBD 400a HDPP1/S,TRANSFORMER 112.5KVA,SWBD 400A 120/208 LDPP1/S,PANELS: PROJ , SCRN, LPP1/S AND RELAY,with a branch from emergency ckt.))) applicant to bring approved set on monday 7/22/2013NEW PARKING STRUCTURE / MUSEUM BUILDING ( 3-LEVELS PARKING AND 3-LEVELS FOR MUSEUM) THIS APPLICATION  IS FOR THE SERVICE AND DISTRIBUTION FOR THE PARKING STRUCTURE; APPLICATION FOR THE MUSEIUM WILL FOLLOW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23904	10041-20000-13166	8075 W 3RD ST # 100	90048	5	138B177   731	5511022032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	34.07225	-118.36564	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23905	11041-20000-25370	930 S HILGARD AVE	90024	5	135B153   541	4360006025	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			PC Approved	11/29/2011 12:00:00 AM	ADDRESS	34.06306	-118.44116	Repacing the existing MR16 in the sweat room, with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23906	19041-10000-20240	1273 N TOWER GROVE DR	90210	5	144B157   135	4356026019	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.09358	-118.42434	Permit fee is $0.00 due to AB1414.PV Tile-System: Plan check for a 10.9KW DC / 9.0KW AC PV1 roofmounted system with with (5) strings, and (2) energy storage system interconnecting through the load center covering a total roof of  763-SQ FT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23907	12041-20000-00805	16424 W MARBRO DR	91436	5	165B137   371	2284020025	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2012 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.14696	-118.49117	New roof mount 4KW  PV system with microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23908	13041-10000-05724	180 N GLENDALE BLVD	90026	1	135A209   207	5160013014	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.06403	-118.25974	ON SITE ARE TWO BUILDINGS ( 170 AND 180 GLENDALE ) SERVICE AND PANELS AND CKTS ARE ON 13041-10000-03964; THIS APPLICATION IS FOR 180 GLENDALE. methane zonebldg 170 is 13041-10000-05722	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23909	11041-20000-15092	600 W WILSHIRE BLVD	90017	9	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	10/12/2011 12:00:00 AM	ADDRESS	34.04796	-118.25622	Ti in an existing office. EPC is for T24& emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23910	17041-20001-14335	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar carports on roof of existing parking structure (Northridge Fashion Center). 825.9kW ungrounded system. (1992) 365W pv modules. Every two modules are connected to a 730W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23911	19041-20000-31642	14616 W ISLA VISTA DR	91402	6	201B149   887	2650019060	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.2474	-118.45101	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON A NEW SFD. SYSTEM SIZE IS 3.15KW DC/2.835 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23912	12041-20000-27002	13310 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	PIN	34.31253789	-118.42511113	Enphase system on roof of single family dwelling..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23913	13041-20000-15852	464 N FAIRFAX AVE	90036	5	141B177  1186	5527030026	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	07/15/2013 12:00:00 AM	ADDRESS	34.07996	-118.36125	New Fire Alarm system in an existing low-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23914	17041-10000-24708	923 S SANTEE ST #3	90015	14	126A209   130	5145016038	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.03968	-118.25417	Plan check for Title 24 only in existing space, remove HID fixtures indoor and replace with new LED fixtures. Tota area: 3600 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23915	15041-10000-41711	555 W 5TH ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	T-24, TI TO THE LOBBY LEVELS, EAST AND WEST IN AN (E) HIGH RISE COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW RECEPTACLES AND LIGHTING TO THE OUTDOOR CANOPY AND LOBBY. TOTAL SQ. FT(INDOOR AND OUTDOOR). 23,746	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23916	18041-20001-37020	16410 W BOSQUE DR	91436	5	165B137   572	2291016018	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Issued	10/26/2018 12:00:00 AM	ADDRESS	34.1447	-118.49077	10/26/2018 Changes to an approved set of plans. PV module manufacturer and model has changed and module count has increased to (48) total modules.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 14.625 kWdc/13.8 kWac and consists of (2) inverters, (45) modules, (2) load centers, and (2) Tesla PowerWalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23917	13041-20000-20144	6311 W WILSHIRE BLVD	90048	5	135B177   471	5510028003	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM			PC Approved	07/29/2013 12:00:00 AM	ADDRESS	34.06366	-118.36573	Plan check for energy only. Existing emergency lighting. Change of many fixtures to LEDs. Low-rise commercial. Bar/restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23918	16041-10000-38638	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.16935	-118.53104	Plan check for power and Title 24.  New 3-Story Medical Office Building core and shell.  New 3,000 amp 480/277 volt service.  Total area = 91,934 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23919	15041-10000-11686	1336 W 73RD ST	90044	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Expired	05/15/2017 12:00:00 AM	ADDRESS	33.97354	-118.2994	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23920	16041-20001-43891	11069 W FENWAY ST	91352	7	201B173   256	2538017026	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.24823	-118.37272	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23921	10041-20000-04901	6100 W WILSHIRE BLVD 1st &p1	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	11/10/2010 12:00:00 AM	ADDRESS	34.06282	-118.36187	energy plan check 1st floor and p-1 level	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23922	16041-10000-24940	3510 W 8TH ST	90005	10	132B193   681	5093010016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.05744	-118.30716	PC FOR ENERGY ONLY. Change of use OF EXISTING  Retail to A Restaurant. TOTAL AREA 960 SQ FT.B # 16016-10000-15369	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23923	13041-10000-08433	6622 W MELROSE AVE	90036	5	141B185   612	5524017019	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/02/2013 12:00:00 AM	PIN	34.08319192	-118.33943965	13041-10000-08433PC FOR ENERGY. TI TO EXISTING 1STORY 3 METERS TO 2. (interior remodel of existing retail space for 6620 and new restroom for 6622)TI, Remove interior non-bearing wall to merge 2 commercial spaces into 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23924	13041-20000-07391	12901 W CORAL TREE PL	90066	11	102B157    26	4211009005	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			PC Approved	03/22/2013 12:00:00 AM	ADDRESS	33.97791	-118.42275	Provide 4 new office spaces on the mezzanine level enclosing existing luminaires, and to create a new conference room on the main floorlevel which shall include installing new luminaires.  No calculation for installed lighting is required for the mezzanine remodel.  The conference room remodel does require installed lighting calculations.  Both portion of the remodel are subject to section149-I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23925	16041-10002-29628	10319 N NORRIS AVE	91331	7	204B165   115	2537004029	[Q]M1-1-CUGU, [Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.25712	-118.40313	CHANGES TO APPROVED SET OF PLANS. CHANGES SHOWSN AS 800A SERVICE WITH 3 NEW PANELS. FURNISHING OFFICE SPACE. RECONNECTING LOADS TO NEW SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23926	17041-20001-40187	9830 N GLADE AVE	91311	12	201B101   197	2727012032	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM			PC Approved	11/17/2017 12:00:00 AM	ADDRESS	34.249	-118.60812	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23927	17041-10001-33190	2051 E 103RD ST	90002	15	091-5A215 121	6046021001	A1(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	PIN	33.943533	-118.23588444	Changes to an approved set of plans, Note changes under delta 5 only. Scope of work includes adding Gp, B, NGL for future work and relocation of barn circuits from panel B to CL. Future site lighting and conduit has been shown on plans. PC only.__________________________________Plan check for power and energy of new Community Education Center, Barn, Mastergardener Center. Total area: 44,220. Application 1 of 3 This permit covers the main switchboard and panels CAC, GL, GP and EV panels.Note: 3 Buildings supply by 1 Service(800A). There are 3 electrical application with 1 plan. Building application number: 17010-10000-02862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23928	18041-10000-08180	1155 S FLOWER ST Tower 3-42-stories	90015	14	127-5A207 344	5138015045	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Expired	02/02/2024 12:00:00 AM	ADDRESS	34.04185	-118.2655	PC for new FA system for Tower 3 of Oceanwide Plaza. This firewarning system is networking with the fire warning systems of Tower 1, Tower 2, and Retail Podium.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23929	14041-10000-31291	380 WORLD WAY T 93	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 plan check only.  Total area = 350 sq. ft.T.I. to existing commercial kiosk in the airport.  Lighting, recepticles, and one new 225A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23930	18041-10000-12799	18011 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			PC Info Complete	06/12/2018 12:00:00 AM	ADDRESS	34.26497	-118.5254	T-24, PC for energy only. Change of use from Retail to Restaurant and Tenant Improvement. Scope includes new lights and receptacles. Total affected area is 1540 Sq. Ft. B#18016-10000-10717	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23931	17041-10000-38962	6707 W 88TH ST	90045	11	096B161   808	4122020011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Expired	04/01/2024 12:00:00 AM	ADDRESS	33.95725	-118.4071	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH AC POWERWALL. TOTAL SYSTEM SIZE IS 5.0KWac. ADDING ONE NEW 5.8KVA / 13.5KWH AC POWERWALL. (16)MODULES-SOLARCITY STANDARD SC325(1)INVERTER-SOLAREDGE SE5000A-US-ZB-U(1)AC POWER WALL 5.8KVA 13.5KWH	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23932	12041-10000-06715	783 W GATUN ST 1-133	90731	15	021B197  1087	7445002051	[T][Q]RD1.5-1	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Apartment			03/23/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	33.75748	-118.29434	New outdoor street lighting for a tract home neighborhood on property not within the public right of way.  Lights are fed off a 100A panel.  PLAN CHECK ONLY for Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23933	19041-10000-12788	210 S ANDERSON ST	90033	14	127-5A219   3	5172010001	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.04565	-118.22676	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23934	14041-10001-10320	13442 W HATTERAS ST	91401	2	174B157   245	2343014038	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.17515	-118.42604	(((EXPEDITE FEES))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23935	16041-20001-21235	10352 W DIAMOND ST LOT 17	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23936	18041-20000-16098	13025 W AZTEC ST	91342	7	228B161   481	2511030031	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM			PC in Progress	05/27/2018 12:00:00 AM	ADDRESS	34.32084	-118.41633	Plan check for ground mounted system in SFD, system size: 6kW with 20 modules and 1 inverter(6.0kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23937	14041-20001-08875	24849 S SEAGROVE AVE	90744	15	039B209   262	7404028029	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	33.80043	-118.25981	expedited plan check per applicant request.(((pv1. install 3kw roof mounted pv system, interconnect with main service panel.(1) transformer-less inverter with power optimizers; solar edge model se3800(12) modules renesola jc250m)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23938	19041-10000-24675	12020 W RUNNYMEDE ST	91605	2	186B165   479	2317014005	QC2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.20563	-118.39538	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23939	16041-10000-14571	1616 W 209TH ST #3	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	PV1 INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A MULTI-FAMILY HOUSE.(10) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER:SOLAREDGE SE3000A-US-ZB-U	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23940	18041-10000-27394	7267 W MELROSE AVE	90046	5	141B181   541	5525012013	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	03/08/2024 12:00:00 AM	ADDRESS	34.08365	-118.34807	PLAN CHECH FOR TITLE 24 ONLY - CHANGE OF USE FROM AUTO PARTS SALES TO 2 - RESTAURANTS. ( 20' X 90' spaces) - TOTAL AFFECTED AREA = 1806 FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23941	18041-10000-20485	355 S GRAND AVE LEVEL #7	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	Energy plan check for an office T.I located on the 7th floor of a highrise building. Scope includes new lighting and equipment with a total area of 5,810-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23942	14041-10000-08931	12806 W STANWOOD DR	90066	11	114B149    76	4247010015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.01205	-118.44934	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23943	18041-20000-22971	15165 W VENTURA BLVD Suite 245	91403	4	168B145   932	2264007010	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Issued	06/20/2018 12:00:00 AM	ADDRESS	34.15357	-118.46363	Plan check for Title 24 Energy only in existin space office T.I.  Total area:3137sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23944	11041-10000-09381	1511 N WILCOX AVE	90028	13	147A187   100	5547017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM	05/09/2011 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	34.09839	-118.33114	New fire alarm system for existing building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23945	19041-10002-06925	1243 W DENNI ST	90744	15	033B201   613	7415020029	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	33.78423	-118.2795	(expedite fees for pv)pc for pv system. system includes (21) modules (REC solarr: RETP2), (21) 320 solar edge optimizers, (1) LG chem 5kw battery, (1) solar edge 7600 inverter. (1) load panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23946	12041-20000-05713	16133 W VENTURA BLVD s.650	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.15675	-118.4847	s.650 office t.i.Energy, emrgencyFire/ Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23947	16041-10000-23449	13833-13835 W SATICOY ST	91402	6	186B153    17	2214019031	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	10/05/2016 12:00:00 AM	ADDRESS	34.21014	-118.43441	PC FOR 600A SERVICE UPGRADE. RECONNECTING EXISTING LOADS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23948	16041-10000-14302	3600 W WILSHIRE BLVD 100	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.06156	-118.30335	PC FOR ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT WITH UNCOVERED DINNING AREA . 2436 SQ FT. B# 16016-10000-04684.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23949	14041-20001-01732	7127 N CANOGA AVE	91303	3	183B105   302	2111028032	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.19999	-118.59788	[[[[PLANCHECK ONLY]]]]]CHANGES TO APPROVED SET OF PLANS. PLANCHECK  FOR EMERGECNY LIGHTING ONLY PER INSPECTORS REQUEST.PERMIT AND T24 PC UNDER 14041-20000-01732Change to lighting in an existing commercial space, not a first time tenant.  Office with workshop in the back, not a first time tenant.  Load is less than 400 amps.  PLAN CHECK for T-24 only.  No emergency lighting required per the applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23950	18041-10000-24404	514 S ALVARADO ST	90057	1	133-5A203 160	5154029008	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	03/12/2021 12:00:00 AM	ADDRESS	34.06003	-118.27436	PC FOR POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO DENTAL OFFICE TI. SCOPE INCLUDES NEW PANEL, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 4746 SQ.FT.B#18016-10000-20869	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23951	17041-20001-42975	308 S GLENROY AVE	90049	5	135B145    43	4366020007	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.07017	-118.46029	expeditepv1install roof mounted pv system sized 11kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23952	17041-10002-31105	832 N HANLEY AVE	90049	11	138B137   387	4494009012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.07315	-118.48689	changes to approved set. scope includes addition of 12 modules and a subpanel. total system size is 17.9KWac.(Note: resedential service was upgraded 400amps, permit number 17041-90000-32884partial permit fees paid under original (for previously approved system)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23953	19041-10000-03363	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM			PC Info Complete	04/09/2019 12:00:00 AM	ADDRESS	33.74512	-118.26099	MEDIUM VOLTAGE, REPLACE EXISTING MV (4160 V) DELTA WYE STARTER FOR 600 HP PUMP-MOTOR WITH A NEW 4160 V SOFT STARTER. RECONNECT EXISTING INCOMING CABLES TO SOFT STARTER AND REPLACE 5 KV CABLES FROM NEW STARTER TO THE MOTOR. TEST & COMMISSION THE STARTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23954	11041-20000-09610	9157 N DE SOTO AVE	91311	12	198B109   215	2746009047	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.23726	-118.5888	PLAN CHECK POWER AND ENERGY FOR NEW COMMERCIAL SHELL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23955	18041-10000-08316	3489 S MAPLEWOOD AVE	90066	11	114B149  1035	4244022016	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.00497	-118.44891	Plan check for PV roof mounted system with Tesla battery backup system. with 10 modules connected to load center with Tesla battery in SFD. PV system size 3.6kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23956	17041-20000-09253	20642 W DUMONT ST	91364	3	171B109   379	2166018012	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.16185	-118.58307	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.7.68kW ungrounded system. (24) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23957	13041-10000-32790	3150 W SAN FERNANDO ROAD	90065	13	153B209   408	5458002013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.11582	-118.24713	NEW FIRE ALARM SYSTEM FOR A FULLY SPRINKLERED BUILDING. GOODWILL. 121 DEVICES AND 2 PANELS, 4 BOOSTER PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23958	10041-20003-08915	6675 W HOLLYWOOD BLVD	90028	13	148-5A185  90	5547009006	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM			PC Approved	10/26/2010 12:00:00 AM	ADDRESS	34.10173	-118.33567	revision to approved plans delta 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23959	19041-10000-21741	241 E CENTURY BLVD #2	90003	8	091-5A205  81	6052016024	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	33.94575	-118.27027	PV1 roof mounted, scope work is 12 modules (LG Solar 335W) with optimizers (P370 SE), and a central inverter (SE3800H-US). System size is 3.8KWac/4.02KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23960	10041-10000-15951	633 N MARINE AVE	90744	15	030B205   664	7416034036	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM			PC Approved	08/19/2010 12:00:00 AM	ADDRESS	33.77811	-118.26383	ADD NEW LIGHT FIXTURES, NEW CIRCUITS. Plan check for T24. (permite was pulled # 10041-40000-12053)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23961	13041-10000-06428	10201 W PICO BLVD BLDG 101-5TH FL	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	REMODEL OFFICES AT FOX STUDIO BLDG 101 5TH FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY STPERMIT TO BE OBTAINED AT ELECTRICAL COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23962	19041-20000-01718	17361 W ROSCOE BLVD	91325	12	192B133   228	2787019007	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Apartment			01/15/2019 12:00:00 AM	07/09/2020 12:00:00 AM		Permit Finaled	07/15/2022 12:00:00 AM	ADDRESS	34.22125	-118.5118	1600A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23963	18041-10000-33504	1771-1831 W BLAKE AVE	90031	13	147A213   157	5442009019	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			Reviewed by Supervisor	10/26/2018 12:00:00 AM	ADDRESS	34.09655	-118.24246	**Only one set of plan provided** Plan check Power only for Tract Homes. There are 8 Typical small lot subdivision, total 88 SFD. Each lot has its own utility service.(Type I) consist of (1) 8 SFD: 1200A, 120/240V, 1ph, 3W(Type II) consist of (2) 7unit SFD: 1200A, 120/240V, 1ph, 3W(Type III) consist of (1) 5 unit SFD: 800A, 120/240V, 1ph, 3W(Type IV) consist of (2) 5 unit SFD: 800A, 120/240V, 1ph, 3W(Type V) consist of (4) 6 unit SFD: 800A, 120/240V, 1ph, 3W(Type VI) consist of (1) 6 unit SFD: 1000A, 120/240V, 1ph, 3W(Type VII) consist of (1) 7 unit SFD: 1200A, 120/240V, 1ph, 3W(Type VIII) consist of (2) 7 unit SFD: 1200A, 120/240V, 1ph, 3W(One building Plan check# 18010-10000-01954)NEW 3 STORY SINGLE FAMILY DWELLING WITH ATTACHED GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23964	12041-20000-06549	21860 W BURBANK BLVD 300	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.17198	-118.60379	Tenant Improvement for existing building.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-90000-04728	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23965	15041-20000-34990	23340 W OXNARD ST	91367	3	177B093   841	2041006016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.17776	-118.63592	Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (42) modules, (42) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23966	19041-10000-42034	1800 N VINE ST	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.10393	-118.3265	PC FOR ENERGY ONLY, SCOPE OF WORK IS RELOACTING LIGHTS, TOTAL AFFECTED AREA IS 402 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23967	19041-10000-06438	333 S GRAND AVE #2225	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	TI IN SUITE #2225. INSTALL NEW LIGHTS. T-24 ENERGY ONLY.  AREA OF WORK 3,423 SF.BULDING PERMIT: 19016-1000-02055	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23968	17041-20000-34672	135 N WESTGATE AVE	90049	11	135B141   707	4402010011	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.064	-118.47331	Plan check for the addition of a battery back-up system to an existing PV system for a single-family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23969	15041-20000-33417	12745 W MCCORMICK ST	91607	2	171B161   371	2346024010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Expired	11/03/2017 12:00:00 AM	ADDRESS	34.16593	-118.41098	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (31) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23970	17041-10000-28374	8966 N RESEDA BLVD	91324	12	195B125   109	2769001020	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.23376	-118.53589	REMOVE HID  FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLYTotal affected 40000 sq.ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23971	12041-20001-27347	1026 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	PIN	34.02400284	-118.2895744	"BULLETIN 5.  Modification to previously approved set of plans for ""DELTA 7"" only.  PLAN CHECK FOR FIRE ALARM SYSTEM IS NOT A PART OF THIS APPLICATION.            New construction and rennovation for a commercial building.  Full Plan check.  Site is in a Methane Zone, Level 1 with less than 2 inches (Passive system only)."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23972	17041-10000-38943	11911 W WESTMINSTER PL	90066	11	114B153    17	4249017020	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Issued	01/17/2018 12:00:00 AM	ADDRESS	34.01261	-118.43229	Install new 5kW AC rooftop solar and 13.5kWh ESS on a SFD. (19) modules with (19) optimizers, (1) inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23973	13041-10001-06121	380 WORLD WAY T56	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	NEW PINKBERRY FOR SMALL TENANT SPACE AT THE LAX AIRPORT. NEW TOM BRADLEY TERMINAL. FIRST TIME TENANT, PC FOR POWER AND ENERGY. SPACE T56. ]]]]]]]]]]]]]]]]]]]]] mz 07/04/2013 This is title 24, energy for storage area [[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23974	16041-20000-21246	5628 N SEPULVEDA BLVD	91411	4	174B145   405	2243003006	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Info Complete	05/19/2017 12:00:00 AM	ADDRESS	34.17296	-118.46593	Addition to (E) four story hotel.  New 1600A 120/208V meter section to (E) service.  Plan check for power and energy.  Building permit filed under 16014-20000-00983	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23975	18041-20000-01968	16637 W RUNNYMEDE ST	91406	6	186B137   145	2226011017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.20632	-118.49588	pv1install roof mounted pv system sized 5kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
23976	12041-20000-19086	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	08/14/2012 12:00:00 AM	ADDRESS	34.09815	-118.32564	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23977	19041-20002-26475	1717 E 7TH ST	90021	14	124-5A215  56	5164022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Approved	09/06/2019 12:00:00 AM	ADDRESS	34.03495	-118.23573	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CLOUDED CHANGE ONLY, CHANGE SINGLE LINE PANEL BOARD TO MAIN LUG ONLY PANEL BOARD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23978	15041-10000-11503	14515 W VENTURA BLVD	91403	4	166-5A151 107	2265010012	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.15118	-118.44931	PC FOR T24 ONLT, ATT STORE. REMODELING EXISTING RETAIL STORE. TOTAL AREA 1942 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23979	07041-10002-07422	1411 N DETROIT ST 1-23	90046		147B181   853	5548018009	R3-1		Hollywood	Hollywood Hills West			Electrical	Electrical	Apartment			04/13/2010 12:00:00 AM			PC Approved	04/13/2010 12:00:00 AM	ADDRESS	34.0966	-118.34544	PC only. 23 units apartment. title 24. 4 story. Vaiance for fire alarm.ORIGINALLY APPROVED AND PERMITTED ON 07041-30000-0742; INSPECTION IS ON GOING OF 10-05-09. THIS SET OF PLANS REPRESENT AS BUILT SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23980	15041-20001-24966	20301 W VIA SANSOVINO	91326	12	219B113   270	2701061010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	34.2969	-118.57556	Expedited per customer request.PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(27) Kyocera KU2656 Modules(1) Solaredge SE 6000A Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23981	18041-20000-24988	10940 W WILSHIRE BLVD Suite-1410&1425	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.05822	-118.4452	Plan check for Title 24 only in existing commercial office remodel. new lighting with existing circuits. Total area: 6079 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23982	16041-20000-45750	4939 E YORK BLVD	90042	14	156A225   225	5476017019	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.12175	-118.20762	Plan check for energy only. New single story restaurant building. 1,971sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23983	15041-20000-20057	23219 W INGOMAR ST	91304	12	189B093   586	2020022024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.21204	-118.63291	Plan check for PV roof mounted system. System size: 7.6kW with 40 modules and 1 inverter(7.6kW) Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23984	19041-10000-22723	17407 W VALERIO ST	91406	6	186B129   736	2202014006	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.20554	-118.51227	pc for pv-1. system consists of 13 modules (sunpower spr-x22-360-E-AC) with microinverters. 1-100 subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23985	16041-20001-15839	17647 W PRAIRIE ST	91325	12	198B129   194	2766001021	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.2396	-118.51952	EXPEDITE PER CUSTOMER REQUEST.PV1ISTALL ROOF MOUNTED PV SYSTEM SIZED 16.4KW INTERCONNECTED WITH MSP.(50) MODULES(2) SOLAREGDE INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23986	15041-20000-09716	6320 N TOPANGA CANYON BLVD #1605	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and energy for WellsFargo Bank first time tenant. Total area: 2544 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23987	14041-20000-35475	10566 N HORSE CREEK AVE	91040	7	207B177   246	2528035020	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.26186	-118.36138	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 7.5kW. Grounded system.30  275W pv modules across 3 strings (10+10+10) go to fused combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23988	11041-10000-22612	175 S FAIRFAX AVE	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	Electrical and T24 energy for a new Trader Joe's in an existing space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23989	09041-10001-23709	13510 W PAXTON ST	91331	7	210B157   278	2535003004		North Valley				1043.20	Electrical	Electrical	Public Safety Only			02/23/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	06/29/2010 12:00:00 AM	ADDRESS	34.27246	-118.424	INSTALLATION OF A FIRE ALARM/ CENTRAL STATION MONITORING SYSTEM AT A BEST BUY STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23990	18041-20000-32162	5670 W WILSHIRE BLVD 1950	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23991	18041-10001-15820	20209 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.27509	-118.57388	Delta 5 and 6 revisions with addendums. CHANGES INCLUDES 4 EA NEW PANELBOARDS, CIRCUITS, KITCHEN EQUIPMENT, REVISED LIGHTING AND POWER PLANS, AD SERVICE LOAD RECALCULATION.  INVERTERS REPLACED BATTERY PACKS AS EMERGENCY POWER SOURCES. CHANGES ARE CLOUDED AND IDENTIFIED . ((((((FULL PC FOR WHOLE FOODS MARKET BUILDOUT (41,00SF) TO EXISTING CORE AND SHELL RETAIL BUILDING WITH 1 LEVEL MEZZANINE. SCOPE OF WORK INCLUDES NEW CIRCUITS AND PANELS. TOTAL SQ. FT. 42517.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23992	18041-20000-20772	14235 W OXNARD ST	91401	6	177B153   828	2240025028	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Issued	06/18/2018 12:00:00 AM	ADDRESS	34.17954	-118.44357	2-STORY ADDITION FOR COMMERCIAL STORAGE BUILDING.  PLAN CHECK FOR LIGHTING ENERGY CONSERVATION REQUIREMENTS. TOTAL AFFECTED AREA 6025 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23993	16041-10000-10378	5528 N BEVIS AVE	91411	4	174B149   982	2249027010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.17104	-118.45616	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.232KWac.(16)AC MODULES-SUNPOWER E20-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
23994	12041-20000-12580	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM			PC Approved	06/01/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin # 186 CS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23995	18041-10000-37344	11671-11677 W NATIONAL BLVD	90064	11	120B153   926	4258009032	C2-1VL, R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	34.02326	-118.43794	New 4 story, Type VA, mixed use building- 46 apartments, office and retails spaces on ground floor over two levels, Type IA, subterranean garage. New 2000amp service, 120/208V. 800 amp distribution board to Residential loads, 400amps to house loads and 1000 amps to future tenants.  17 typical units, Total indoor and outdoor Sq. Ft. 46236.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23996	13041-10001-31593	534 S MAIN ST	90013	14	129A211   253	5148020004	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			Reviewed by Supervisor	04/24/2015 12:00:00 AM	ADDRESS	34.04577	-118.24914	REVISIONS TO PERMITTED SET OF PLANS- ADDED AN EMERGENCY GENERATOR WHICH WILL SUPPLY EMERGENCY LOADS;NEW PANELS AND CKTS AND TRANSFER SWITCHES(((((((( POWER AND ENERGY PLAN CHECK FOR  A NEW MIXED USE BUILDING. NEW 7 STORY APARTMENT/RETAIL ( 2 LEVELS OF RETAIL ON THE BOTTOM AND 5 LEVELS OF APARTMENT). NOT A HIGHRISE ACCORDING TO APPLICANT.TOTAL OF 159 UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
23997	19041-10000-04301	19700 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.85221	-118.2903	REPLACE EXISTING FA CONTROL PANEL AND ANNUNCIATOR,ADDING FA DEVICES, AND RECONNECTING EXISITNG FA DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
23998	13041-10000-18271	6174 N DEBS AVE	91367	3	177B089   233	2033025016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.18339	-118.64869	INSTALLING ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 2.45 kW IN A 1-STORY HOUSE. (10) TRINA TSM-245PC05} with optimizers. (1) solaredge SE3000A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
23999	14041-20000-20062	9623 W LA CANADA WAY	91040	7	207B181   171	2549011003	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.26166	-118.34193	4KW PV1 roof-mounted system with (1) Solaredge SE3800A inverter, (16)Renesola JC250M modules and Solaredge P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24000	19041-10000-02092	4908 E YORK BLVD	90042	11	156A223   254	5477002002	C1-1, [Q]C4-1XL	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Issued	01/17/2019 12:00:00 AM	ADDRESS	34.12168	-118.20866	Plan check per applicant request.Plan check for a spinkler monitoring system with (1) fire alarm panel and (4) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24001	16041-20000-30472	1444 S ALAMEDA ST	90021	14	120A215    62	5167017019	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.02382	-118.23908	ADDITION OF NEW 800KW GENERATOR AND TRANSFER SWITCH TO EXISITNG DISTRIBUTION BOARD.  GENERATOR IS OPTIONAL.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24002	17041-10000-07502	1172 N NAPOLI DR	90272	11	129B133   203	4408003009	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2017 12:00:00 AM			PC Info Complete	06/01/2017 12:00:00 AM	ADDRESS	34.04957	-118.50314	PC FOR POWER FOR A (N) SFD with attached garage. SRVICE 600A, 12/240 1PHASE, 3W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24003	19041-20001-14507	5449 N COSTELLO AVE	91401	2	174B153  1347	2247010028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM			PC Approved	05/10/2019 12:00:00 AM	PIN	34.17001544	-118.4381109	Expedite per applicant request Plan check for PV and battery back up system installed into existing PV system, PV system size: 4.2KW with 1 inverter(7.6KW) and 1 battery LG Chem 9.8kWh and 14 PV Modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24004	14041-10000-03576	9301 N TAMPA AVE UNIT #50	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/07/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Commercial TI - minor remodel to front of Apple Store in Northridge Fashion Center.  Plan check for Title 24 compliance for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24005	11041-10000-25375	582 S MATEO ST	90013	14	126A217   105	5164007001	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.03901	-118.23266	"CHANGE OF USE FROM EXISTING RETAIL STORE (35'X 99' 9"") TO  COFFEE ROASTING FACILITY & COFFEE BAR / RETAIL ,PLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24006	15041-10000-43622	633 W 5TH ST 45TH FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24007	14041-20000-15624	7936 N DE SOTO AVE	91304	3	189B109   493	2108029004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.21479	-118.5883	New roof mounted PV system with 300W Optimizers, and two 3.8KW transformerless inverters.  Total system size 8.67KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24008	11041-10000-09796	3506 W 3RD ST	90020	4	135B197   170	5502008015	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Finaled	09/30/2011 12:00:00 AM	ADDRESS	34.0689	-118.29194	New 800 ampere overhead service and new 800 ampere service rated disconnect to resupply an existing 800 ampere distribution board.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24009	15041-10008-27142	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	33.93845	-118.42964	"PC, CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 9 ON PLANS.  SCOPE OF WORK INCLUDES ADDITION OF CIRCUITS AND A NEW PRE CONDITIONED AIR CART ADDED TO ""MDB"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24010	14041-10001-07049	8144 N WILLIS AVE	91402	6	192B149   574	2210014018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.21917	-118.45516	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL  A 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(14)MODULES: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24011	12041-10000-13993	8847 W VENICE BLVD	90034	10	123B169  1238	4312008045	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.03063	-118.38653	Change of use to office.  New 800A service and switchboard.  Plan check for power and energy. Existing 2 story commercial building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24012	17041-10001-12061	850 E 111TH PL	90059	8	088-5A209 241	6071022006	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			Reviewed by Supervisor	03/29/2019 12:00:00 AM	ADDRESS	33.93557	-118.25914	"DELTA ""1"" CHANGES TO APPROVED SET TO REFLECT REROUTING OF POWER FOR THE COMPRESSORS. SCOPE INCLUDES 300KVA 240/480 TRANSFORMER WITH NEW FEEDERS AND 480V GEAR IN NON-CLASSIFIED AREA OF A CNG FUELING STATION."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24013	15041-10002-26639	2310 N APOLLO DR	90046	4	153B177   463	5569008027	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.11295	-118.36424	12/31/02015CHANGES TO AN APROVED SET OF PLANS.  REDUCTION OF NUMBER OF PANELS FROM 66 TO 48 KYOCERAKU2606XPA AND REPLACE EXISTING 200 AMP PANEL.  PV1, INSTALL NEW 17.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(66) MODULES: KYOCERA KU2606XPA(2) FRONIUS IG PLUS A 7.5    (((((((((     permit fees waved due t senate bill 1222        2012    ))))))))) mz	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24014	10041-20001-17421	16255 W VENTURA BLVD #100	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	02/07/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.15711	-118.48768	Supplemental plan check from previously approved plans.  Changes include feeder routing and additional subpanels.  All changes indicate by DELTA 2 as shown on plans.  No changes in T-24 energy load calculation.  Plan check for power only. *****Plan check power and energy for medical office w/eye surgery TI, suite 100. Not check for OSHPD. ****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24015	12041-20000-08833	6600 N TOPANGA CANYON BLVD #2008	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	T. I. - New restaurant in exist. Westfield Topanga Mall	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24016	16041-10000-41831	2410 N MANDEVILLE CANYON ROAD	90049	11	141B133   235	4493005001	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.08086	-118.50104	FULL PC FOR SINGLE FAMILY. NEW SERVICE OF 600A 120/240VNEW PANELS AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24017	14041-20000-11692	2153 N GROVELAND DR	90046	4	151-5A173 130	5567010003	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.11008	-118.37618	mel@precisesolarenergy.compv1 single family. using enphase m215 4.08KW AC microinverter. nonstandard plan. system size 5.13KW DC. using 19 modules 270W  e-mail applicant upon completion of plan check.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24018	15041-10000-42604	8978 W WONDERLAND PARK AVE	90046	4	153B169   389	5564024016	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.11532	-118.39082	PV1, INSTALL 9156W DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(28) MODULES: SUNPOWEER SPR-E20-327(2) INVERTERS: SMA AMERICA SB3800TL-US-22-240 & SB6000TL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24019	13041-10000-34434	18624 W KIPTON PL	91356	3	165B125    74	2177016007	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.15199	-118.5378	PV1, Install a 12.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) inverter(s)[SOLAREDGE # SE6000A-US] and (49) modules[HANWHA # HSL60P6-PB-4-250TW] for 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24020	10041-10000-18344	8500 W BEVERLY BLVD # 735	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I.  REMODEL OF BEAUTY ROOM AT THE VICTORIA'S SECRET STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24021	13041-20000-33871	3361 S MCLAUGHLIN AVE	90066	11	117B153   551	4249008017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.01742	-118.43264	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6 KWAC. 26 MODULES AND 2 INVERTERS. SUBMITTED PER APPLICANT REQUEST.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24022	12041-10000-26363	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.06086	-118.27891	TI IN AN EXISTING HISTORICAL HOTEL.   INSTALL NEW OUTDOOR LIGHTING TO PROVIDE LIGHT ON THE BUILDING ONLY. (T-24 MAY BE EXPEMPT TO BE VERIFIED DURING EPC)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24023	18041-20000-27270	11444 W OLYMPIC BLVD 9TH FLOOR	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.03654	-118.44363	Plan check for Title 24 Energy only in existing space. T.I. existing office space. Total area: 1460 sq ft. B#18016-10000-21199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24024	15041-20000-40455	10262 N NORRIS AVE	91331	7	204B165   110	2537003042	QMR1-1VL, [Q]M1-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.25666	-118.4022	TI to existing commercial building (office). Plan check for energy only. Adding new lighting including emergency. Total sqft. 8,526.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24025	16041-10000-05598	7817 N LANKERSHIM BLVD TLC-2	91605	6	189B169   659	2310025031	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.21268	-118.388	T-24, CHANGE OF USE FROM CLINIC/OFFICE TO OFFICE SPACES ON TLC-2. SCOPE OF WORK INCLUDES ADDING NEW LIGHTING NO NEW RECEPTALCES. TOTAL SQ. FT. 5522	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24026	18041-10001-01795	2471 N BEACHWOOD DR	90068	4	153A189   126	5585019024	RD2-1XL	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			No Progress	01/10/2019 12:00:00 AM	ADDRESS	34.11496	-118.32169	SUPPLEMENTAL APPROVED SET DELTA 1 ONLY ADDING ONE ADDITIONAL HORN STROBE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24027	17041-10000-28767	23101 W SHERMAN PL Suite #410	91307	12	183B097   851	2021014047	(T)(Q)CR-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Issued	08/15/2017 12:00:00 AM	ADDRESS	34.20115	-118.63006	PC FOR T24 ENERGY ONLY. OFFICE TI. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24028	14041-20000-05005	6626 N KENTLAND AVE	91307	12	180B101   285	2038031010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Expired	04/13/2016 12:00:00 AM	ADDRESS	34.19098	-118.61745	pv1 single family dwelling. total system size 6.6kw ac using microinverter. enphase m215. nonsandard plan	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24029	16041-20000-31506	11424-11426 W VANOWEN ST	91605	2	180B169    30	2320019001	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM			PC Approved	09/06/2016 12:00:00 AM	ADDRESS	34.19379	-118.37989	Plan check for energy only. Remodel interior commercial spaces. New lighting (incl. emergency). 1,000sqft per unit/space (total of 2).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24030	15041-10000-37113	22635 W CANTARA ST	91304	12	189B097    79	2013006018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.21784	-118.62027	Install a roof mounted solar array on a SFD. Interconnect with 200A MSP w/ a 175A main.System size: 10.2kW (6+4.2). Ungrounded system. (35) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24031	17041-20000-11171	8055 N RESEDA BLVD	91335	3	189B125   165	2103009039	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.21698	-118.53627	pv2install roof mounted pv system sized 30kw interconnected with  msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24032	16041-10001-09983	1425 S OCEAN FRONT WALK	90291	11	106-5A143  17	4226007002	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	33.98756	-118.47407	CHANGES TO THE APPROVED SET OF PLANS NOTED UNDER DELTA-2.  ADDING 5 FLORESCENT LIGHT IN THE SAME AREA.  EXISTING  AREA: 1,350 SQ. FT.PERMIT WILL BE ISSUED UNDER MASTER E#	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24033	19041-20000-44248	6080 W CENTER DR ste 520	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	33.97713	-118.39172	ENERGY ONLY T24 PLAN CHECK. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 7054 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24034	10041-10000-04601	6400 N OWENSMOUTH AVE	91367	3	180B105    64	2146005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	05/24/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	ADDRESS	34.18653	-118.6013	T.I. for a commercial building.  Install general and emergency lightings. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24035	12041-10000-31237	550 S HOPE ST	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM			PC Approved	01/15/2013 12:00:00 AM	ADDRESS	34.04989	-118.25574	HIGH RISE 2ND FLOOR/MEZZANINE.  T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24036	11041-20000-26529	7225 N WOODMAN AVE	91405	2	183B157    14	2216034048	C1-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.01	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	34.20182	-118.43147	T.I.  Existing Ralphs market.  Remodel of the sales area.  Adding new circuits and new equipment that will be over 400 amps in new load.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24037	19041-10000-21385	13402 W BEACH AVE	90292	11	108B153   925	4230004039	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	10/05/2020 12:00:00 AM	ADDRESS	33.99121	-118.44422	Full plan check for an office T.I located in a 2-story buildiing with a new 800-amp service, new equipment and lighting. Total lighting area  is 10,513-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24038	15041-10000-28976	1660 W ANAHEIM ST	90710	15	033B193   373	7411008034	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			PC Info Complete	10/16/2015 12:00:00 AM	ADDRESS	33.78627	-118.30659	Install a new 100A DPB to supply power to 10 new 1HP pumps as well as a new 15kVA transformer and mini power center.  Plan check for power.  Hazardous classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24039	13041-20000-31314	925 W 34TH ST # 221/222	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	PIN	34.02383917	-118.28572873	ROOM 221/222 TO CAD/CAM DISPLAY LABORATORY PC FOR T24 ENERGY ONLY. ALL WORK WILL BE INTERIOR PER CONTRACTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24040	18041-10001-02341	1125 N NAPOLI DR	90272	11	129B133   263	4408004016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM			Corrections Issued	02/22/2018 12:00:00 AM	ADDRESS	34.04828	-118.50432	Expedited fees for PVPV1, New roof mounted solar system in a SFD with an energy storage system. (2) Inverters, 7.6KWAC and 5.2KWAC, (39) module, (1) load center, (3) AC Tesla Batteries.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24041	10041-10000-10907	6420 W WILSHIRE BLVD	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	06/09/2010 12:00:00 AM		Permit Finaled	07/26/2010 12:00:00 AM	ADDRESS	34.06365	-118.36922	installation of  three panels and 2 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24042	12041-10000-08271	1900 S AVENUE OF THE STARS 2nd fl	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	05/21/2012 12:00:00 AM	ADDRESS	34.05979	-118.41671	replacing luminaires in the women restroom on the 2nd flplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24043	17041-20001-23968	15940 W SKYTOP ROAD	91436	5	162B141   197	2286016002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	34.14078	-118.48015	expeditepv1install roof mounted pv system sized 20kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24044	15041-10000-00790	1661 W COLORADO BLVD	90041	14	162A225    65	5669017002	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.13964	-118.20257	Energy plan check for a restaurant TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24045	16041-20001-28097	9013 N OAK PARK AVE	91325	12	195B133    19	2690005014	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.23488	-118.50578	PV1.  Install 13 kW roof mounted ungrounded PV system.  SolarEdge 11.4 kW inverter with power optimizers and (50) 260W modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24046	19041-30000-48296	431 S BURNSIDE AVE tower 41	90036	4	135B181   326	5509005009	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Apartment			11/26/2019 12:00:00 AM	04/22/2021 12:00:00 AM		Issued	04/22/2021 12:00:00 AM	ADDRESS	34.06636	-118.35098	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW SERVICE UPGRADE TO 4000AMP, 120/208V 3 PHASE. REPLACING ALL UNIT PANELS NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24047	13041-20000-30187	5425 N TAMPA AVE	91356	3	174B117   587	2163014019	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	PIN	34.16972478	-118.55378134	PV1 TRANSFORMERLESS SYSTEM. SYSTEM SIZE 6KWAC. 26 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24048	17041-10001-21873	11401 N PORTER RANCH DR BLDG 10	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	06/28/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 10 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 15 unit apartment with 1,200 amp 208 volt service.       Building 10 of 10.  Type II.       Building permit #17010-10000-02387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24049	18041-20000-28153	4406 N ESTRONDO DR	91436	5	165B133   123	2289030002	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.15126	-118.50166	pv1install roof mounted pv system sized 15.2KW AC interconected with msp.(48) panasonic 330W modules(48) p400 optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24050	15041-10000-33332	13069 W VICTORY BLVD	91606	2	180B161   789	2326017002	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	PIN	34.18883938	-118.41818567	NEW FIRE ALARM SYSTEM FOR LA FITNESS. 1 FA PANEL AND 86 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24051	19041-20001-37417	3655 N VERDUGO VISTA TER	90065	14	154-5A219 131	5472010022	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	34.1187	-118.22354	9/24/19CHANGES TO APPROVED SET DELTA 1 ONLY. RELOCATION OF MODULES. <<<Plan check for PV roof mounted system, PV system size: 5.2KW AC, 6.0KW DC with 15 PV Modules and 15 microinverters, and sub-panel.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24052	14041-10002-15812	1 W WORLD WAY WEST	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	PIN	33.94461393	-118.39808495	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 8 ON THE FLOOR PLANS.  CHANGES INCLUDE MODIFICATIONS TO THE LIGHTING FIXTURES AND ENERGY CALCULATIONS.Plan check for power and lighting.  Total area = 25, 595 sq. ft.Redevelopment of terminal 6 project.  Replacement of existing light fixtures, power outlets, equipment, low voltage devices, and primary facility electrical infrastructure.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24053	16041-10000-40315	7806 N RESEDA BLVD	91335	12	189B125   947	2102016084	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.21235	-118.53581	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 40680 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24054	16041-20000-20465	2644 W PICO BLVD	90006	1	129B197  1127	5075007005	[Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Expired	08/08/2018 12:00:00 AM	ADDRESS	34.04704	-118.29597	Plan check for PV roof mounted system. System size: 22kW with 72 modules and 2 inverters(11.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24055	18041-10000-01776	6201 W HOLLYWOOD BLVD #124	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM			PC Info Complete	01/17/2018 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC for T24 only for new lighting for TI for change of use from office to ice cream shop. Installing new lights, receptacles and equipment. Total area is 970sqft. B# 17016-10000-32523. Note: Inspection to verify that dimming is located in back of service area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24056	17041-20001-35684	845 S MANHATTAN PL 1-33	90005	4	132B193   754	5093002024	R4-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			Reviewed by Supervisor	10/11/2017 12:00:00 AM	ADDRESS	34.05676	-118.31027	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.54 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24057	17041-10000-29827	1302 W PAPEETE ST	90744	15	033B201   396	7415018007	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	33.78678	-118.27984	PC FOR PV SYSTEM ROOF MOUNTED. TOTAL SIZE 7KW AC USING MICROINVERTER SYSTEM. ENPHASE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24058	14041-10000-34551	13689 W FOOTHILL BLVD	91342	7	222B157    46	2509015027	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.30872	-118.43163	Power plan check for new commercial building.  Core and shell project only.  Connecting 1 services (800 A amp) to tenants and installation of lighting in common areas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24059	15041-20000-01480	6250 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	Restaurant T.I. and (2) new dining patios at the existing building.  Install subpanels, transformer, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24060	19041-20000-52378	933 S PARK VIEW ST 1-22	90006	1	132A201   345	5136002008	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Apartment			12/18/2019 12:00:00 AM			PC Info Complete	03/18/2020 12:00:00 AM	ADDRESS	34.0541	-118.28277	Plan check for power and energy for 1200A 208v 3phase service with 700A distribution board and 500A (1 Electircal meter), lighting and associated electrical load. Total area: 27554 sq ft. B#19010-20000-00220	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24061	13041-20000-08650	14525 W NORDHOFF ST	91402	7	198B149   556	2639008023	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.30	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.23555	-118.44889	Convert a Tint/Stereo Shop to a Office space.  Load is 100 amps per applicant.  Change to lighting and receptacles.  PLAN CHECK ONLY for Energy, No Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24062	19041-10000-02278	4677 W HOLLYWOOD BLVD	90027	4	147B197   314	5542001004	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	01/18/2019 12:00:00 AM	ADDRESS	34.10101	-118.29108	TITLE 24 PLAN CHECK FOR EXISTING TEA/COFFEE SHOP, TOTAL SQFT = 850CHANGE OF USE 14' X 65' FROM RETAIL TO COFFEE/TEA/BOBA SHOP AND INTERIOR T.I.  NEW RESTROOM, INTERIOR NON-LOAD BEARING PARTITIONS, NEW FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24063	16041-10000-05462	2738 N ALLESANDRO ST	90039	13	148-5A211  94	5442024001	R2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.10221	-118.24819	PV1 roof mounted solar system installation to a single family nome interconnected to the main service. (2) Central inverters rated at 6.6 kw total (32) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24064	13041-10000-06669	1433 S GRIFFITH AVE	90021	9	123A211   421	5132021029	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.02929	-118.25078	PLAN CHECK FOR TITLE 24. REPAIRS TO OFFICES. LOAD LESS THAN 400A. PERMIT IS FOR THREE BRANCH CIRCUITS. PANEL IS EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24065	14041-10001-00742	5857 S CENTRAL AVE STE # 110	90001	9	108B209  1588	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM			PC Approved	07/18/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	(((7/18/2014  Changes made to approved set.  Replace 200A 3P breaker w/ 100A 3P breaker)))Plan check for power and energy for First time tenant, just take out little ceasar fast food. Total area 1190 sq ft.****Permit number for core and shell related to  this building is 12041-10000-30230.****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24066	18041-20000-05196	7022 N ALABAMA AVE	91303	3	183B105   584	2138013008	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			02/12/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	01/29/2021 12:00:00 AM	ADDRESS	34.19804	-118.59888	New 3-story 9-unit apartment building.  New 800A 240/120V 3ph-4w service.  Plan check for power and energy. Building permit under 16010-20000-06247.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24067	18041-20000-21336	15213 W CAMARILLO ST	91403	4	168B145   411	2264003031	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.15772	-118.46446	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM FOR 11.4KVA SYSTEM. SYSTEM CONSIST OF CENTRAL INVERTER(SE 11400A-US) WITH 38 MODULES USING P400 OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24068	15041-10006-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM			PC Approved	12/12/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 36 ON PLANS. REVISED TO FLOOR PLANS AND ADDED 2 PANELS FOR FUTURE CIRCUITS ON SEPARATE PERMIT. THIS APPLICATION WILL COVER PC FOR THE CHANGES AND PERMIT FOR 2 ADDED PANELS. THIS IS FOR PACKAGE 6A ONLY. THIS IS SUBMITTAL 2/2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24069	10041-10000-23244	1063 S LA BREA AVE	90019	10	132B181   941	5084012024	C2-1	Central	Wilshire	P.I.C.O.		2162.00	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.05558	-118.34465	Ti in the office area of an existing church . EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24070	11041-20000-00716	12045 E WATERFRONT DR Bldg 1	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	PIN	33.98229149	-118.40627052	Plan check for new installation of roof mounted 59.2KW Photovoltaic System on Building 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24071	11041-20000-19057	9590 W HIDDEN VALLEY ROAD	90210	4	156B165   229	4387007001	RE20-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2011 12:00:00 AM			Corrections Issued	10/21/2011 12:00:00 AM	ADDRESS	34.12115	-118.40524	PLAN CHECK FOR NEW 2-STORY ACESSORY LIVING QUARTER IN THE REAR YARD FROM 600A SERVICE (3 OF 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24072	13041-20000-17422	550 S FLOWER ST #4220	90071	14	130-5A209 186	5151024004	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	ADDRESS	34.05028	-118.25708	Change to lighting in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24073	16041-20000-40004	12025 W WATERFRONT DR 4th Floor	90094	11	105B165   915	4211011031	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	33.98265	-118.40487	Office TI in (E) commercial highrise office building.  Plan check for energy.  9,334 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24074	16041-20001-40388	6028 N CALVIN AVE	91356	3	177B117   619	2153035022	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.17989	-118.55544	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.4 kWac and consists of (55) modules, (55) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24075	12041-10000-19122	928 N WESTERN AVE 1-49	90029	13	144B193  1345	5535020007	(Q)RAS3-1VL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Apartment			08/14/2012 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.08731	-118.30896	PLAN CHECK FOR NEW 5 STORY MIXED USE APARTMENT BUILDING WITH  49 UNITS. FIRST LEVEL FUTURE COMMERCIAL RETAIL. NEW 2000A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24076	14041-20003-10657	18518-18526 W PARTHENIA ST	91324	12	195B125   900	2785004031	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.22805	-118.53686	SUPPLEMENTAL PERMIT TO ADD THREE SUBPANELS #C,D,E.PC FOR NEW SERVICE UPGRADE. 800A SERVICE PROVIDING POWER FOR 2 TENANTS. 400A EACH. PLAN CHECK FOR POWER ONLY. MAIN BREAKER TO BE TYPE LC SERIES RATED WITH DISTRIBUTION BREAKERS TYPE FA. SERIES RATE TO 100KAIC MAXIMUM. PER MANUFACTURE SPEC SHEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24077	16041-10000-31360	2176 W 30TH ST	90018	10	120B189   374	5052025011	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	10/05/2016 12:00:00 AM	ADDRESS	34.02724	-118.3144	PV SYSTEM ROOF MOUNTED. TOTAL SYSTEM SIZE 3KW AC USING TOTAL OF 6 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24078	12041-20000-11910	9242 W LA TUNA CANYON ROAD	91352	7	198B185    80	2401036005	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2012 12:00:00 AM			PC Approved	06/27/2012 12:00:00 AM	ADDRESS	34.23624	-118.33447	New house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24079	19041-20000-51546	16204 W BERTELLA DR	91436	5	168B137   644	2284016022	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.15396	-118.48639	PV1 PLAN CHECK FOR NEW ROOF PV AND ESS. PV SYSTEM SIZE IS 7.56 KW DC/7.484 KW AC CEC. ESS SIZE IS 40.5 KWH. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER, A LAOD CENTER, AND (3) 5.8 KVA BATTERIES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24080	17041-10000-13074	6625 S STANFORD AVE	90001	9	102B205   103	6007018014	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			PC Info Complete	05/17/2017 12:00:00 AM	ADDRESS	33.97901	-118.2631	PC for power only. Plan check for new 2000 Amps service, relocating HDB1 800 A panel, and  600 panel in recycling center. Existing load to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24081	15041-20000-22534	3616 S TROUSDALE PKWY Room#145	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.01983	-118.28534	Plan check for Title 24 only in USC Allan Hancock Foundation (AHF) existing space. Total indoor area:2456sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24082	15041-20000-40829	1569 E 41ST PL	90011	9	114A213    86	5116012027	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			Reviewed by Supervisor	12/15/2015 12:00:00 AM	ADDRESS	34.00763	-118.2461	PV1, roof mounted solar system 3.8kW AC interconnect to (E)100A Service.(14) HANHWA Q CELL Q-PRO G4 260(1) SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24083	16041-10000-16772	2040 W COLORADO BLVD	90041	14	162A223   118	5686003019	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.13897	-118.212	Title 24 plan check only.  Total area = 910 sq. ft.    T.I. to existing restaraunt space.  3 new panels (total load < 200 A) with associated HVAC, appliance loads, and lighting loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24084	13041-20000-13734	1985 W ESCARPA DR PV1	90041	14	160-5A223 377	5685019012	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	34.13226	-118.20982	PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 5.04KW. 21 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24085	19041-10000-34724	3322 W WILSHIRE BLVD 100	90010	10	132B197    69	5094007021	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.03	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	34.06156	-118.29485	CHANGE OF USE (TENANT IMPROVEMENT) 6300 SF (E) OFFICE TO (N) UMAYA RAMEN RESTAURANT. INCLUDING NEW NON RATED PARTITIONS, NEW LIGHTING FIXTURES, NEW HVAC UNITS ON ROOF AND NEW FINISHES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24086	13041-10001-34519	4545 W RUSSELL AVE	90027	4	150B197   950	5590016025	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.10463	-118.28903	Expedited RSES plan check per applicant request.{{PV1, Install a 5.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE6000A-US] and (23) modules[TRINA SOLAR # TSM-250PA05.18] on a 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24087	14041-20001-02711	10625 N OAKDALE AVE	91311	12	207B113   141	2708020032	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	03/19/2014 12:00:00 AM	ADDRESS	34.26315	-118.5671	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 17KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. CONNECTION TO 400A SERVICE.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24088	17041-10000-01543	15400 W SHERMAN WAY STE 110-140 & 150	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.20099	-118.46839	T-24, PC FOR ENERGY ONLY. T.I TO AN EXISTING OFFICE SPACE ON FIRST FLOOR OF A LOW RISE BUILDING. TOTAL AFFECTED AREA IS 10150 SQ. FT. B#16016-20000-30870	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24089	17041-10001-28566	1247 W 30TH ST	90007	9	120B197   247	5055010040	(Q)R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.02754	-118.29025	Supplemental PC for changes in scope of work. All existing fire alarm devices labeled (E) to be reconnected to new fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24090	13041-20000-35492	13242 W BOMBAY ST	91342	7	225B157   515	2512022027	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Closed	04/15/2014 12:00:00 AM	ADDRESS	34.31321	-118.42094	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NNONSTANDARD PLAN 3 STRINGS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24091	14041-20002-33232	400 S WESTGATE AVE	90049	11	132B145   347	4401005035	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.05579	-118.47142	3.5.2015 - Changes to approved set. Change module layout on roof and location of inverters (move inverters from roof to inside of garage). Delta 2 changes. Service located on outside wall, add DC disconnects within sight of PV disconnect to comply with Fire Code requirement.[PV1 SFD. TOTAL SYSTEM SIZE 13KWDC /16KW AC USING 2 CENTRAL TRANSFORMED INVERTERS RATED 8KW EACH. LEAVING ROOM FOR FUTURE SOLAR ADDITION.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24092	19041-10000-42198	861 N NORTH SPRING ST	90012	1	135A215   266	5408031015	C2-2	Central	Central City North	Historic Cultural North		2071.03	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.06351	-118.23627	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24093	10041-10001-20959	523 E ROSE AVE	90291	11	111B141   296	4240005003	C4-1	West Los Angeles	Venice	Grass Roots Venice		2733.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	33.99859	-118.47333	CHANGE OF USE FROM A SINGLE FAMILY DWELLING TO A RESTAURANT WITH RETAIL SPACE AND AN ACCESSORY OFFICE. PLAN CHECK FOR POWER AND ENERGY. Change some lighting and title24.12-16-10	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24094	13041-10001-04198	12474 N BRADFORD PL	91344	12	219B129   416	2608013028	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.29662	-118.51596	MODIFICATION TO APPROVED SET OF PLANS. MODULE TYPE CHANGED FROM REC245 PE TO REC 250 PE  ***************************************************************************PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY TWO STORY DWELLING. TOTAL SIZE 3.02KW. USING 14 SOLAR MODULES REC 245 PE. USING MICROINVERTER ENPHASE M215-60-2LL-S22.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24095	16041-20000-00237	10040 N HEATHERGLEN CT	91325	12	204B129   599	2734006016	RA-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.25383	-118.52183	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24096	11041-20000-14425	10861 W WEYBURN AVE	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	07/09/2012 12:00:00 AM	ADDRESS	34.06247	-118.44344	Plan check for new Target Store. EPC is for power & energy. Existing service and main distribution board. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24097	12041-10000-18837	1639 S WESTWOOD BLVD	90024	5	129B153   211	4324026019	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Public Safety Only			08/10/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.05213	-118.43928	NEW FIRE ALARM SYSYTEM IN A 2 STORY DAY CARE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24098	12041-10000-23829	236 S LOS ANGELES ST	90012	9	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			10/17/2012 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.04922	-118.24386	Construct 176-unit apartment with retail and basement garage. Variance is required to separate the FIRE ALARM plans	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24099	14041-10000-14463	13140 W ADDISON ST	91423	4	171B157  1111	2358009025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.16112	-118.41949	PV1, INSTALL 11.47 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24100	17041-10000-17103	1553-1555 W SUNSET BLVD UNIT A	90026	13	139-5A209 170	5419028004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.07664	-118.2566	RETAIL TI. FIRST TIME TENANT. PC FOR POWER AND ENERGY. BUILDING# 17016-10000-11526	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24101	14041-20000-10940	2430 N LAKE VIEW AVE	90039	13	148-5A209 306	5440024020	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.10095	-118.25407	PV1.  Install 6.0 kW roof-mounted PV system, interconnect with main service panel.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24102	10041-10001-24969	848 W 7TH ST	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	34.04904	-118.25956	MODIFICATION TO APPROVED PLANS:  LIGHTING FIXTURES WENT FROM FLOURESCENT TO LED, LOAD CHANGE TO PANEL L, CHANGE TO TITLE 24 CALCULATION.****ORIGINAL WORK: TENANT IMPROVEMENTS OF EXISTING  7-11 STORE RETAIL  SPACE(~2946 S.F.) ;  NEW FINISHES, CEILINGS.  REMODEL RESTROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24103	13041-10000-20465	1975 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.06159	-118.20463	Title 24 plan check per inspector's request (permit no. 13041-10000-20294).  Office and corridor lighting.Original work description: ADD (2) CIRCUITS FOR DOOR OPERATOR AND DAMPER ACTUATOR.  ADD LIGHTING SENSORS IN BATHROOMS. UNDER EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24104	16041-30001-17651	175 W 42ND ST	90037	9	114A203    99	5111019022	RD2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			Reviewed by Supervisor	05/31/2016 12:00:00 AM	ADDRESS	34.00745	-118.27574	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (15) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24105	14041-10000-03364	2121 S AVENUE OF THE STARS STE 2150	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM			PC Approved	02/07/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	TI in an existing commercial highrise office suite.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24106	13041-10001-35672	16752 W VINTAGE ST	91343	12	204B137  1004	2685011002	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	ADDRESS	34.25188	-118.49778	Expedited RSES plan check per applicant request.{{PV1, Install 12.25 kW DC roof-mounted solar array for a one story building, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 6000A-US. (49) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24107	17041-10000-43762	21551 W PRAIRIE ST	91311	12	198B105   228	2746014022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.2392	-118.60019	REPLACE EXISTING INDOOR/OUTDOOR FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24108	13041-10000-14962	2527 S HARCOURT AVE	90016	10	123B181   855	5057001021	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2186.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Expired	07/22/2015 12:00:00 AM	ADDRESS	34.03315	-118.34613	PV1 6.125KW XFRMLESS. 1STORY. NONSTD. ROOFMOUNT. (1)powerone PVI-4.2-OUT-S-US-Z  and  (25)TRINA TSM-245PC05.18}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24109	17041-20000-05813	9320 N GLENOAKS BLVD	91352	6	198B173    53	2538011009	M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.23797	-118.37472	Plan check for power only. Replace commercial building's 800A main service panel due to fire damage. All feeders and panels existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24110	13041-10000-25120	435 E 20TH ST	90011	9	121-5A207  36	5127019015	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.02819	-118.26103	TITLE 24 PLAN CHECK ONLY. 1 STORY. 2838 SQFT. OFFICES. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24111	11041-20000-24727	17236 W WEDDINGTON ST	91316	5	171B133   203	2258005018	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.16673	-118.50908	New 11.040 KW roof mounted PV system for single family residence using ENPHASE M215.  Variance has been filed to use the M215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24112	19041-20001-30790	5401 W RED OAK DR	90068	4	153B193   333	5588001027	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.11246	-118.30806	$0 PLAN CHECK FEE DUE TO SB1222SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. MINOR RELOCATION OF SOME PV EQUIPMENT AND ADDING A DC DISCONNECT SWITCH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24113	15041-10002-26965	19600 S VERMONT AVE	90502	15	057B197    31	7351033009	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	33.85227	-118.2903	CHANGES TO APPROVED SET OF PLANS. UPDATED NOTES TO CAP OFF FURNITURE EQUIPMENT SINCE THE FURNITURE IS UNPOWERED. PERMIT FOR ADDITIONAL RECEPTACLE ISSUED FOR CIRCUIT 26. ALL NOTES CLOUDED DELTA C REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24114	14041-20000-07786	7055-7079 W SUNSET BLVD	90028	13	147B181   581	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.09813	-118.34337	Install facade lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24115	19041-10000-27089	6401 W WILSHIRE BLVD	90048	5	135B173   815	5510023018	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	02/11/2020 12:00:00 AM		Issued	02/11/2020 12:00:00 AM	ADDRESS	34.06401	-118.36834	Full PC (Enegrgy and power) for New 16 story type construction mixed-use building with 112 apartment dwelling units, area of scope is 145945sf, Service size 4000A @480/277V,3Ph,4Wire , 5 level above ground parking.  ***** Fee estimate adjusted for pre cut check plan checker to verify ******	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24116	13041-10000-16369	523 W 7TH ST	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.04717	-118.25611	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING. EXISTING RESTAURANT TENANT IMPROVEMENT. SCOPE OF WORK IS LIGHTING ONLY (<400A).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24117	14041-20000-33912	6256 N TOPANGA CANYON BLVD C-2250	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/08/2014 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	T. I.  &  CHG OF USE FROM RETAIL TO DAY SPA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24118	15041-10005-26434	1101 S FLOWER ST tower 1	90015	14	127-5A207 330	5138015***	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Expired	02/02/2024 12:00:00 AM	ADDRESS	34.04284	-118.26457	Full plan check for tower 1,  55 stories hotel and residential units  with basement level and ground floor retail.  Application number is supplemental to origianal core/shell, 15041-10000-26434 , due to all service and major equipmemt were approved  from the original application; The plan is mainly for new Title-24, power and  lighting ckts with update feeder and service load calculation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24119	17041-10001-44638	3315 W 41ST ST	90008	10	114B185   300	5024028027	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM			PC Approved	12/22/2017 12:00:00 AM	ADDRESS	34.01015	-118.33021	Expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24120	10041-20000-23778	7800 W WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2780.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	12/02/2010 12:00:00 AM		Permit Finaled	11/21/2011 12:00:00 AM	PIN	33.93790872	-118.42837934	Plan check power for temporary movable batch plant at LAX. Installation in methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24121	18041-20002-16988	21250 W CALIFA ST #115	91367	3	174B105    16	2149002018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM			PC Approved	10/09/2019 12:00:00 AM	ADDRESS	34.1769	-118.59414	10/9/19CHANGES TO APPROVED SET DELTA C ONLY CHANGES IN LIGHTS.02-05-2019 Changes to an approved set of plans, Changes include addtional wall lighting in the auditorium and main lobby, all changes has been clouded. and addtional 5 circuits for wall lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24122	13041-10000-23000	1491 S GLENVILLE DR	90035	5	129B165   236	4306007014	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.05264	-118.3933	PV1.  Install 6.86 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24123	18041-20000-28018	812 N HIGHLAND AVE	90038	4	141B185   212	5524004025	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.08567	-118.33841	Plan check for PV roof mounted system, system size: 3.8kW with 8 modules and 1 inverter(3.8kW) connected to 200A sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24124	19041-10000-40231	14250 W GREENLEAF ST	91423	4	165B153   726	2266010009	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	12/28/2019 12:00:00 AM	ADDRESS	34.14733	-118.44368	0$ final fees perCalifornia Sente Bill 1222 and  AB1414[EPLAN] PLAN CHEK FOR ROOF MOUNTED 15.75KVA PV1 SYSTEM CONSISTING OF 50 MODULES USING  IQ7X MICROINVERTERS WITH 2 ESS(TESLA POWERWALL) CONNECTED TO EXISTING 400A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24125	15041-20000-30344	2972 N HUTTON DR	90210	5	156B157   224	4385019024	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			Reviewed by Supervisor	09/23/2015 12:00:00 AM	ADDRESS	34.12384	-118.4243	PV1. Install ground mounted PV system sized 12 kW. Interconnected with main service panel. (56) Mitsubishi PV 270W Modules(2) SMA SB 6000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24126	19041-20000-34537	9315 N GEYSER AVE	91324	12	198B121   409	2763020008	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Issued	08/30/2019 12:00:00 AM	ADDRESS	34.23961	-118.54259	PV1.  Install 6.405 kW rated PV syste.  (21) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24127	16041-20000-00652	8666 W FOOTHILL BLVD	91040	7	204B189    15	2560003029	C2-1VL, P-1VL, QC2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.25956	-118.3221	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/fire rebuild. Total lighting area = 1,550 sq. ft.Note: Building permit has been pulled under 15016-20000-00727	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24128	10041-10000-10947	4501 W COLORADO BLVD Room #620	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	06/10/2010 12:00:00 AM		Permit Finaled	07/15/2010 12:00:00 AM	ADDRESS	34.14246	-118.2705	"TI in an existing office area (In-house Nurse Station) in room #620 of  building ""01"" of Baxter.           Plan Check is for T-24 Energy calcs and emergency lights."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24129	17041-10000-34298	127 E 9TH ST	90015	14	126A211    33	5145014002	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.04104	-118.25421	PC for power for new roofmounted HVAC and chiller equipment. Load over 400A. Installing two new distribution panels on (E) build.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24130	13041-10000-34382	1207 S VERMONT AVE	90006	1	129B197   797	5078028004	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			12/10/2013 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.04886	-118.29184	New fire alarm system for fully sprinklered building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24131	11041-20000-26717	6100 W WILSHIRE BLVD Ste 1100	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM			PC Approved	12/14/2011 12:00:00 AM	ADDRESS	34.06282	-118.36187	Existing office.  Adding new light fixtures in the conference room of suite #1100.  Plan check is for energy only.  Permit has been pulled for the work under 11041-90000-26026	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24132	12041-20000-28603	14006 W RIVERSIDE DR # 61	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/28/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	Install receptacle and lighting in remodeled retail space # 61.  Plan check for T-24 lighting only.  sInspector to verify that only two 4 ampere circuit breakers are installed in the Silver Bullet panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24133	14041-10000-18360	1200 S CLUB VIEW DR 5	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.06748	-118.42481	PERMIT TO BE PULLED AT EPC COUNTER ONLY. PLAN CHECK FOR ENERGY ONLY. EMERGENCY LIGHTING INSTALLED IN HIGHRISE. SCOPE OF WORK COVERS ONLY CORRIDOR NEXT TO UNIT 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24134	17041-10000-06017	1337 W 52ND ST	90037	9	108B197   123	5002001009	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	33.99519	-118.29937	PC for a PV 1 solar roof mounted system on exiting residential unit. System consists of 10 micro inverters rated at 250 watts each for a total syste size of 2.5 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24135	15041-20000-40209	6345 W TAHOE DR	90068	4	159B185   178	5577037021	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	34.12822	-118.32927	Plan check for PV roof mounted system, addition of 7.6kW system to  existing system  of 5.2kW. New system size: 7.6kW with 31 modules and 1 inverter(7.6kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24136	17041-10000-17384	13701-13707 W VENTURA BLVD	91423	4	165B157   607	2271018008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.14822	-118.4314	PC FOR SERVICE UPGRADE AND CONSOLIDATION. PROVIDING NEW 600A SERVICE TO REFEED EXISTING TENANTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24137	12041-10000-26504	19200 W DEARBORN ST PV1	91324	12	198B121   664	2762017030	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.23719	-118.55072	INSTALL ON THE ROOF OF A SFD A 12KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24138	10041-20000-02748	12000 S MAIN ST	90061	15	084B205  1252	6086001021	C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2414.00	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM	02/17/2010 12:00:00 AM		Permit Finaled	04/14/2010 12:00:00 AM	ADDRESS	33.92341	-118.27368	COMMERCIAL T.I.--INT REMODEL Energy, emergency, egress lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24139	19041-10000-49358	1660 W ANAHEIM ST	90731	15	030B197    11	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM	12/23/2020 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	33.77884	-118.29327	PLAN CHECK FOR THE ADDITION OF A 7.5 HP WATER INJECTION MOTOR IN A OIL REFINERY, HAZARDOUZ LOACTION. THE SCOPE OF WORK ON THE PLANS IS INDICATED BY A CLOUD, REFERNCE SHEETS WERE ALSO PROVIDED. LOAD CALULCTIONS WERE UPDATED ACCORDINGLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24140	18041-20001-11203	16444 W ROSCOE BLVD	91406	6	189B137     4	2205003906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM			PC Approved	05/30/2018 12:00:00 AM	ADDRESS	34.21987	-118.49574	SUPPLEMEMNTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES NOTED UNDER DELTA 2 INCLUDING DISTRIBUTION BOARD TO MATCH FIELD CONDITIONS AND DWP SERVICE LETTER OF 600A, AND DECREASE CONDUCTOR SIZING FOR TRANSFORMER(LUGS TO BE RATED AT 75 DEG. C. MIN.)PLANCHECK FOR POWER. TEMPORARY POWER FOR AIRPLANE HANGAR. 600 AMP SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24141	10041-20000-23758	545 S FIGUEROA ST 5TH Floor	90071	9	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.0514	-118.2582	T.I. to existing high rise building on 5th floor of Phase 6 as shown on plans.  Install general/emergency lighting in woman dressing area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24142	19041-10000-04929	23037 W OXNARD ST	91367	3	177B097   453	2039008026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.17934	-118.62886	PV1 . NEW ROOFTOP SOLAR SYSTEM CONSIST OF 38 MODULES (SUNSPARK TECH SST-300W) AND 38 MICROINVERTERS (ENPHASE IQ7-PLUS-60-2-US). SYSTEM SIZE IS 11.4KWdc and 10.08KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24143	17041-20000-22170	3231 N STEVEN DR	91436	5	159B141   212	2293014019	RE15-1-H	South Valley	Encino - Tarzana	Encino	Yes	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			Reviewed by Supervisor	07/12/2017 12:00:00 AM	ADDRESS	34.13339	-118.48222	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24144	19041-20000-52358	6732 S CRENSHAW BLVD	90043	8	102B185   460	4006025011	MR1-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	01/11/2021 12:00:00 AM		Permit Finaled	08/09/2021 12:00:00 AM	ADDRESS	33.97708	-118.33067	Plan check for power and energy 600A Service upgrade new indoor lighting and equipment. Total area: 5005 sq ft. B#19016-20000-37005	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24145	18041-20000-32154	21300 W VICTORY BLVD ste 110	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.18813	-118.59618	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24146	15041-10000-02146	15102 W GREENLEAF ST	91403	4	166-5A147 144	2276021001	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.15045	-118.46239	Permit fee is 0.00 due to Senate bill 1222PV system size: 14kW. 2 inverters (8kW and 6kW). 49 modules (28 and 21). 100A subpanel. 225A main service panel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24147	19041-20001-23209	360 E 2ND ST 6TH FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	34.04805	-118.24012	07/08/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the power and lighting floor plans and have been reflected onto the Title 24 compliance forms. *****Original Work Description*****Plan check for Title 24 only in existing space 6th Floor high-rise building, Tenant Improvement. Total area: 11932 sq ft. B#19016-10000-14457	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24148	16041-10000-31397	1041 W 68TH ST	90044	8	102B197   428	6014020018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	33.97795	-118.29325	ROOF MOUNTED PVPC FOR PV SYSTEM WITH 3KW INVERTER AC USING 8 PV MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24149	17041-10000-15993	10151 W RIVERSIDE DR	91602	4	165B181    48	2424008021	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.15237	-118.35239	PC for power only (phase 1). Service upgrade to 600 Amps 120/240V 1phse, 3Wire. Addition of one new panel for new distribuition system. Installation of conduits only from phase 1 to phase 2 (No conductors).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24150	13041-20000-15018	5425 N CALHOUN AVE	91401	2	171B153    35	2245024016	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	10/19/2013 12:00:00 AM	ADDRESS	34.16939	-118.44234	PV1 FOR 10.50 KW SYSTEM. 42 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24151	16041-10000-11837	11965 W MONTANA AVE 1-49	90049	11	129B141   303	4265007078	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Public Safety Only			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.05133	-118.47199	new fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24152	19041-10000-26904	16861 W VENTURA BLVD SUITE 304	91436	5	168B133   116	2259010002	C2-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Issued	08/13/2019 12:00:00 AM	ADDRESS	34.15939	-118.50076	Energy plan check for an officeTENANT IMPROVEMENT located on the 3rd floor of a commercial building. Scope includes new lighting and equipment with a total area of 1094-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24153	14041-10000-01784	4260 N EAGLE ROCK BLVD 1-56	90041	1	156A219   115	5474022011	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Apartment			01/22/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.12246	-118.22336	Installation of new fire alarm system for 4-story 55-unit low-income housing building.  190 devices coordinated by Edwards i0500 FACP.  Fully sprinklered per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24154	10041-10000-19799	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	02/18/2011 12:00:00 AM		Permit Finaled	11/09/2011 12:00:00 AM	ADDRESS	33.93195	-118.41136	Remodel inflight kitchen.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24155	16041-10000-45736	355 S GRAND AVE STE 3150	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.05191	-118.2525	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR SUITE 3150. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 8851 SQ. FT. B#16016-10000-31149	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24156	16041-20000-21589	10427 W LA TUNA CANYON ROAD	91352	7	195B177    68	2544023011	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.23402	-118.35835	PERMIT FEES $0.00 BY STATE SENATE BILL NO. 1222PV1. ROOFMOUNTED SOLAR SYSTEM. AC MODULES. SYSTEM SIZE:13.11 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24157	18041-10000-13945	5457 N CLEON AVE	91601	2	174B173  1260	2416001013	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Issued	04/17/2018 12:00:00 AM	ADDRESS	34.17026	-118.36873	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24158	14041-20000-08124	15849 W MALDEN ST	91343	12	192B141   144	2673009027	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.2257	-118.47802	PV1. ROOFMOUNTED SOLARSYSTEM. TRANSFORMERLESS STANDARD PLAN. SYSTEM SIZE: 3.25 KW.(13) CANADIAN SOLAR CS6P-250(1) POWER ONE AURORA PVI-3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24159	13041-20000-34546	5152 N TOPANGA CANYON BLVD #A	91364	3	171B101   861	2169005014	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.16331	-118.6056	New rooftop PV system using DC-DC converters for an Existing SINGLE FAMILY Dwelling.  System is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24160	12041-10000-30236	5867 S CENTRAL AVE	90001	9	108B209  1458	6007003900	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.98775	-118.25672	New single story retail building.  New service, new panels, new ckts.  Full plan check.  Core and shell only.  No tenant build out.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24161	18041-20000-14054	14143 W BESSEMER ST	91401	6	177B153   710	2240023028	M2-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.18092	-118.44146	"PC for T24 only for new lighting in auto impound facility. Total area 3140 sqft. B# 18016-30000-07107.CEIS 74700""COMPLY WITH DEPARTMENT ORDER effective date 08/08/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24162	17041-20002-17297	5012 N MAMMOTH AVE	91423	4	171B157  1013	2269002020	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.16154	-118.43229	[[8/3/17 CHANGES TO APPROVED SET. PLANCHECK ONLY.  CHANGING INVERTER TO ABB PVI-5000 AND REPLACING EXISITNG POWERWALL 1 TO TESLA POWERWALL 2]]]]Plan check for roof-mounted solar pv system with dc coupled battery backup for SFD.6kW ungrounded system. (18) 325W pv modules. (1) 5kW Tesla Powerwall backup battery.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24163	13041-10001-11565	18200 W VENTURA BLVD	91356	3	171B125   365	2181008021	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM			PC Approved	12/27/2013 12:00:00 AM	ADDRESS	34.16589	-118.52928	][]TITLE 24 PART 6 ENERGY ONLY PER SUPERVISOR REQUEST. CHANGES MADE TO AN APPROVED SET OF PLANS; LIGHTING MODIFICATIONS REVISED FROM RECESSED TO FLUORESCENTS; PERMIT IS EXISTING] UNDER 13041-10000-11565 [][New one story 3257 sq ft medical office bldg.  New 400A servie, 120/240, 1phase3wire.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24164	18041-30000-25121	1522 S ORANGE GROVE AVE	90019	10	129B177   953	5068026030	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.04874	-118.36605	Plan check for a fire alarm system located in a new (3) story, (17) unit apartment building. Scope includes (1) fire alarm, (1) power supply and (68) fire alram devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24165	18041-10000-10620	8918 N WOODMAN AVE	91331	6	195B153   421	2640016028	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Issued	03/23/2018 12:00:00 AM	ADDRESS	34.23183	-118.43758	Plan check for Title 24 only remove HID fixture and replce with new LED fixtures outdoor lighting. Total area : 37,500 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24166	18041-10000-03587	3405 E GLEASON AVE	90063	14	124-5A227  98	5179017014	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.0362	-118.19511	PC for PV system 3kW(AC) in SFD. Installing 11 modules with optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24167	14041-20000-05222	5817 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	33.97377	-118.41988	ROOF-MOUNTED,PV1 TRANSFORMERLESS SYSTEM.  TOTAL SYSTEM SIZE 3 KW A/C	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24168	19041-10001-15523	527 E VERNON AVE	90011	9	112-5A207  53	5113014016	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2285.00	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.00406	-118.26581	Change to an approved set, change under delta-1,Change includes revising lighting layout and circuits.Permit under original permits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24169	19041-20000-23973	926 N LUCILE AVE	90026	13	142-5A201  95	5427017012	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.08596	-118.2821	Install 40.5 kWh energy storage system and associated distribution for whole house backup.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24170	10041-20000-21035	450 S WESTERN AVE	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	Plan check power and energy for new 3-story retail building.Building supplied by two 2500A services. Plan checked under 2007 CEC (2005 NEC). Modification to separate file alarm has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24171	14041-20000-19224	5116 N WILLOW CREST AVE	91601	2	171B177   899	2419016025	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.16356	-118.36255	PV1Microinverter standard plan.Install a roof-mounted solar array on SFD. System size: 4.8kW(20) Enphase M250 microinverters(20) SolarWorld SW280 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24172	14041-20000-21593	2145 W 85TH ST	90047	8	097-5A191 152	6035028019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/30/2014 12:00:00 AM	ADDRESS	33.96101	-118.31714	New roof mounted PV system with total size 3.3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24173	19041-10001-11031	11051 W VENICE BLVD 1-3	90034	5	117B161  1058	4252008034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.01418	-118.41554	Changes to approved set, scope of work includes reloaction of equipment and going from optimzers to microinveters. Permit has been issued under 19041-10000-11031Orginal Scope:NEW ROOF MOUNTED 3.05KW PV SYSTEM WITH 10 PV PANELS ON A SINGLE FAMILY / DUPLEX HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24174	17041-10000-01539	6705 N CANTALOUPE AVE	91405	2	180B153   237	2238008031	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.19247	-118.43466	PV1, INSTALL NEW 2520 W DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE. AN ADDITION TO AN EXISTING PV SYSTEM. SCOPE INCLUDES ADDING 1.935KWac TO AN EXISTING 3.44KWac PV SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS 5.375KWac.  (9) HANWHA Q-CELL. Q PLUS-BFR-G4.1 280(9) INVERTERS: ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24175	13041-10001-28992	710 W HARRY BRIDGES BLVD	90744	15	027B205   665	7440007901	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	33.7693	-118.27062	Supplemental to original plan change.THIS PLAN  WILL REPLACE ORIGINAL PLAN PERMIT TO BE OBTAINED ON THIS APPLICATION (PLAN CHECK FOR POWER AND ENERGY. PORT OF LOS ANGELES. NEW REPAIRSHOP FOR AUTOMATED CRANES. METHANE ZONE.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24176	16041-20001-36531	900 N NORTH BROADWAY	90012	1	135A215   238	5414013901	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.06408	-118.23726	12/23/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2 and 3. *****Previous Work Description*****Full PC for power and energy for first time tenant. Scope includes new lights, receptacles and sign lighting for  area 1599 sqft.  PC two subpanels and one 75 KVA transformer. **TI WORK ON 1599 SF OF THE TOTAL FLOOR AREA. NEW WALL, POWER, LIGHTING AND FINISHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24177	14041-20000-03242	11520 W SAN VICENTE BLVD	90049	11	129B145   102	4265004043	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Expired	03/31/2016 12:00:00 AM	ADDRESS	34.05292	-118.46124	PC FOR T24 ENERGY ONLY. ZONED FOR FUTURE OFFICES. NEW LIGHTING FOR OPEN OFFICE AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24178	19041-10001-07980	2211 N PANORAMA TER	90039	4	148-5A205 350	5432028002	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2019 12:00:00 AM			PC Approved	04/05/2019 12:00:00 AM	ADDRESS	34.1002	-118.27094	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY RELOCATION OF INVERTER TO INSIDE GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24179	15041-10000-37245	20339 W NORDHOFF ST	91311	12	195B113    59	2781001053	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.23201	-118.57696	FULL PC, SCOPE INCLUDES SERVICE UPGRADE TO 1200AMP AND ADDING NEW DISTRIBUTION BOARDS AND PANELS TO A DATA CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24180	19041-20000-42583	5933 N MONTEREY ROAD	90042	14	150A231   152	5312008026	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Hermon	YES	1837.02	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	11/21/2020 12:00:00 AM	ADDRESS	34.10549	-118.1847	NEW FIRE ALARM SYSTEM IN A NEW BULDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24181	13041-20000-01807	2336 W FAIR PARK AVE PV-1	90041	14	162A221   274	5686022030	RD3-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.13675	-118.21857	SOLAR SYSTEM SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24182	14041-10000-30888	11099 S LA CIENEGA BLVD Suite #210	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.93534	-118.37106	T.I. of (e) office tenant space (3478 sf ) : PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24183	12041-20000-28625	16710 W MAGNOLIA BLVD	91436	5	171B137    86	2259003009	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.16479	-118.4974	New 20kw rooftop photovoltaic system for an existing single family residence.  System uses Solar Edge DC/DC converters and Array is ungrounded.  (Misc. Permit is for Solar Edge Converters)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24184	10041-20005-22501	19600 W PLUMMER ST CABANA-BLDG	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			07/13/2012 12:00:00 AM	09/04/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.2426	-118.5602	"Changes from previously approved plans (10041-20003-22501).  Add new emergency lightings.  *****Most recent version of modified plan fot the new CABANA"" BUILDING (SEPERATE POOL HOUSE AND REC ROOM FOR AN APARTMENT BUILDING THAT WAS APPROVED UNDER 10041-10000-22501).  PLAN CHECK IS FOR POWER & ENERGY.   The permit is for all previous vetsions of the plan.  Not permit is to be issued for 10041-10001-22501.*****"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24185	14041-20000-21018	21650 W OXNARD ST #1700	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Issued	08/05/2014 12:00:00 AM	ADDRESS	34.17901	-118.60107	T.I. to existing high rise building on the 17th floor.  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24186	15041-20001-14961	5501-5505 W PICO BLVD	90019	10	129B177   824	5085030001	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	34.04914	-118.35756	CHANGE IN NUMBER OF FIXTURES. REDUCE NUMBER OF INSTALLED. ALSO CHANGED EMERGENCY LIGHTING TO BUG EYE TYPE. PC FOR CHANGES CLOUDED DELTA  1 ONLY. NO OTHER CHANGES NOTES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24187	17041-10001-31288	355 S GRAND AVE LEVEL 4	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM			Corrections Issued	02/15/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	Supplemental PC for T24 only. Changing light types in areas and adding new circuits. Total new connected load < 400A. All changes clouded delta 17.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24188	12041-10000-29814	6801 W HOLLYWOOD BLVD Ste 400	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I.  Existing restaurant.  Remodel of the interior and exterior light fixtures.  Plan check is for Title 24 and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24189	19041-10000-15357	660 S FIGUEROA ST SUITE 1900	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Issued	07/22/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	TI IN EXISTING OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24190	17041-20000-04286	22950 W VANOWEN ST ste e	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.19343	-118.62746	ti to an existing commercial space suite E.  adding new lighitng new controls to restrooms.  newly connected load <400amps.  plan  check for energy only.  total square footage 260	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24191	13041-10000-26706	380 W WORLD WAY T42R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN-CHECK FOR SIGN LIGHTING. INSTALLING (1) ILLUMINATED WALL SIGN AT LAX - THOM BADLEY INTERNATIONAL TERMINAL. NEW INDOOR SIGNS; NOT INSTALLING LIGHTING CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24192	18041-10000-33427	8876 W PICO BLVD	90035	5	132B169   921	4305014900	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Apartment			08/31/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.05483	-118.38545	Plan check for a new fire alarm system for a six story apartment building. Scope includes (1) fire alarm panel, (5) power supplies and (178) devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24193	19041-10000-14866	9110 N DE SOTO AVE	91311	12	198B109   171	2748037028	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	05/04/2021 12:00:00 AM		Issued	05/04/2021 12:00:00 AM	ADDRESS	34.2358	-118.58833	FULL PC PWR AND ENERGY FOR NEW PROPOSED 1 STORY C-STORE.  SERVICE SIZE 800A, 120/208V, 3PH, 4WIRE. SCOPE AREA 2,055SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24194	19041-10000-39726	10565 W ESTHER AVE	90064	5	126B157   850	4318008016	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.04073	-118.41966	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTM CONSISTING OF 1 CENTRAL INVERTER (SE3800H-US), 13 MODULESUSING P400 OPTIMIZERS AND ESS(TESLA POWERWALL) CONNETED TO EXISTING 225A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24195	19041-10000-13285	9510 S VERMONT AVE	90044	8	093A199    65	6039017075	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	11/12/2020 12:00:00 AM	ADDRESS	33.94986	-118.29139	PC for a lost set of plans(15041-10001-43443). Full PC for Power and energy. Scope includes a new 800A 120/208V 3phase 4 wire service/distribution board, new panelboards and circuits.  B#15014-10000-05927Note: Permit fees will be covered under inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24196	16041-10000-31450	360 E 2ND ST 400	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	Plan check for Title 24 only.  TI to the 4th floor to create new office spaces and conference rooms.  New lighting, receptacles, and HVAC.  Total area = 9,392 SF.   No change of use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24197	17041-20000-39059	14931 W CALIFA ST #101,102	91411	4	177A149   141	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.17768	-118.4586	TI to (E) commercial office space in lowrise building.  Plan check for energy - 15,141 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24198	12041-20000-08937	7920 W SUNSET BLVD #420	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			PC Approved	04/19/2012 12:00:00 AM	ADDRESS	34.09787	-118.36238	T.I. to existing building on the 4th floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-90000-08594	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24199	13041-10000-34394	536 N GRAMERCY PL	90004	4	141B193   961	5522013019	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.08141	-118.3124	PV1, install 4 kw DC roof-mounted solar array for a 1-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3800A-US. (16) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24200	16041-20000-07605	6809 N DELCO AVE	91306	3	183B109   870	2136015007	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.19424	-118.57811	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24201	19041-20000-19948	9121 W LA TUNA CANYON ROAD	91352	7	198B185    42	2545024022	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.23661	-118.3316	PV1.  Install 21.00 kW DC / 18.85 kW AC roof mounted grid tied PV system.  (56) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24202	16041-10000-36013	523 W 6TH ST suite 1110	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE FOR SUITE 1110. TOTAL AFFECTED AREA IS 410 SQ. FT. B#16016-10000-19269	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24203	13041-20000-21813	8100 N DEERING AVE	91304	3	189B105    77	2109002034	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.21702	-118.59489	RENOVATION OF EXISTING WAREHOUSE AND COMPLETE REFURBISH OF BUILDING WIRING. SOME EXISTING LOADS. BUILDING HAS EXISTING 2 SERVICES. RELOCATION OF 1 OF THE SERVICES. PLAN CHECK FOR POWER AND ENERGY. TOTAL AREA 21825 SQ FT. TAILORED METHOD. NONHAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24204	13041-10000-20472	1005 S FAIRFAX AVE	90035	10	132B177   657	5086001040	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	PIN	34.05800719	-118.36424409	PLAN CHECK FOR POWER AND ENERGY. CARLS JR. TENANT IMPROVEMENT. 600A SERVICE. methane zone but no underground work being done. 1 story. Green project type: >$200k.MAJOR INT & EXT REMODEL TO EX DRIVE-THRU RESTAURANT. NEW ROOF & WALL FRAMING OVER EXISTING TO INCREASE BLDG HEIGHT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24205	15041-10000-33177	450 S WESTERN AVE #214-#215 A-C	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	FULL PC FOR ENERGY AND POWER. FIRST TIME MULTI TENANT TO A RETAIL SHOPPING CENTER. ALL TENANTS SHARING THE SAME METER GIVEN DURING THE CORE AND SHELL APPROVAL. TOTAL SQ. FT. 1096. **CORE AND SHELL APPROVED UNDER APP#: 10041-20000-21035 AND CHANGES DONE ON APP#: 10041-10001-21035	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24206	12041-20000-19146	7355 N BALBOA BLVD	91406	6	186B133   803	2227001018	(T)(Q)RD1.5-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Apartment			08/15/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.20442	-118.50145	New 2 story apartment over garage with 14 units.  New 800A service, panels, and branch circuits.  Plan check for power (Verify garage lighting, additional plan check fee may be require).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24207	19041-10000-17869	12746 W JEFFERSON BLVD ste-3-3100	90094	11	102B161  1167	4211033012	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	FULL PLAN CHECK FOR POWER AND ENERGY FOR - CHANGE OF USE PORTION OF 1ST FLOORGROUND FLOOR INTERIOR TENANT IMPROVEMENTS FOR DAYCARE FACILITY.  NO CORE AND SHELL ALTERATIONS. TOTAL NEW CONNECTED LOAD = 125A WITH TOTAL AFFECTED AREA = 7102 SF CONNECTED TO EXISTING 4000A SERVICE 480/277V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24208	14041-20000-06811	14625 W MAGNOLIA BLVD	91403	4	172-5A151 217	2249007007	R1-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	PIN	34.16516326	-118.45108484	pc for fire alarm system for 30 unit apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24209	13041-10000-01555	11100 W SANTA MONICA BLVD 450	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	01/22/2013 12:00:00 AM	ADDRESS	34.04726	-118.44465	T24 FOR OFFICE SPACE ON THE 4TH FLOOR OF HIGHRISE. REARRANGEMENT OF LIGHTING FIXTURES. AREA OF 8007 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24210	14041-20000-17365	3415 S SEPULVEDA BLVD 7th floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.02055	-118.42347	Plan check for energy only. New lighting (incl. emergency) for corridors on 7th floor of high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24211	12041-10000-01418	17456 W HIAWATHA ST	91344	12	204B129    75	2733023033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2012 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.25921	-118.51515	Plan check 7.74KW roof mounted photovoltaic system single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24212	17041-10000-35022	225 S OLIVE ST	90012	14	130-5A211   9	5149010***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM			PC Info Complete	02/09/2018 12:00:00 AM	ADDRESS	34.05317	-118.24961	Energy plan check for a roof deck remodeling Total plan check area is 6,228 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24213	11041-10001-23502	725 W 7TH ST	90017	14	129A209   265	5144029***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	ADDRESS	34.04858	-118.25834	Change to previously approved set of drawings.  Change to lighting, new j-box,  fan.<<<<<New circuits and panels for restaraunt.  Plan check for POWER and ENERGY per applicants request.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24214	13041-10000-21983	10951 W OAK MOUNTAIN PL	91040	7	207B173   508	2528037016	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.26223	-118.36915	][][]APPLICATION # IS ASSOCIATED WITH BOTH PLAN CHECK, AND PERMIT ][][][PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 6.5 KW DC AND 5.616 KW AC. USING MICROINVERTER STANDARD PLAN. [ INVERTER: ENPHASE # M215-60-2LL-S22 |||| MODULES: REC # REC 250 PE]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24215	12041-10000-27962	7328 W 90TH ST	90045	11	096B157  1040	4119017005	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	33.955	-118.42336	3.43 kw roof mounted PV for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24216	09041-10002-20078	818 E 29TH ST	90011	9	118-5A207 333	5128015020	(T)(Q)R3-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Apartment			09/09/2011 12:00:00 AM			PC Approved	09/09/2011 12:00:00 AM	ADDRESS	34.01762	-118.26081	MODIFICATION TO APPROVED PLANS.  CHANGED LOCATION OF MAIN SWITCHBOARD.  New Apartment complex with 3 separate buildings (A, B, C) - Permit will need to be issued for each building.   4 typical units.  Permit is for complete new construction (service, distribution, panels, ckts, etc).  P/C is for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24217	14041-10000-33044	2323-2325 1/2 S SCARFF ST	90007	1	123A201    29	5124012026	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Apartment			11/26/2014 12:00:00 AM			PC Info Complete	08/17/2016 12:00:00 AM	ADDRESS	34.0327	-118.2803	Full plan check for power and energy. Project site is a new construction of 7 condos. Totla lighting area = 10,000 sq. ft. New 600 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24218	19041-20000-32437	11380 N ETIWANDA AVE	91326	12	213B125   510	2870013027	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.27797	-118.5328	PV1. INSTALL 7.59 KW DC/ 6 KW AC ROOFMOUNTED SOLAR SYSTEM AND (1) 6KW INVERTER ON EXISTING 200 AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24219	17041-10000-25666	7361 N LAUREL CANYON BLVD	91605	2	186B165   260	2307022010	(T)(Q)M2-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.20451	-118.39671	TITLE 24 PLAN CHECK TO REPLACE EXISTING (25) FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA = 184000 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24220	19041-10000-10881	8906 S HAAS AVE	90047	8	096A191   238	6036023002	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	33.95601	-118.31651	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 14 MODULES (TSM 280) , 14 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.92KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24221	18041-10000-00429	725 S FIGUEROA ST #3800	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR OFFICE TI IN A HIGH RISE BUILDING 38TH  FLOOR FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW TRANSFORMER, PANELS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 13995 SQ.FT. B# 17016-10000-38104	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24222	12041-20000-02662	14141 COVELLO ST #5A	91405	2	186B153   871	2215001018	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	PIN	34.20782227	-118.44128652	T.I.ENERGY, EMERGENCY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24223	15041-10000-29680	205 E ADAMS BLVD	90011	9	120A207    46	5127037011	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.02435	-118.26718	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24224	18041-10000-07464	10250 W SANTA MONICA BLVD FC5	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for T24 only, TI on an existing Food Court space #FC5. service and panelboards are existing.  Total area 319 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24225	17041-20000-28136	1420 N DETROIT ST	90046	4	147B181   810	5548017041	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.09688	-118.34506	Plan check for roof-mounted solar system on apartment building.32.4kW ungrounded system (9+9+14.4).(98) 395W pv modules. Each module has a 400W power optimizer.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24226	16041-10001-42447	932 S WESTMORELAND AVE	90006	1	132B197  1031	5076003001	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Apartment			12/09/2016 12:00:00 AM			PC Approved	12/09/2016 12:00:00 AM	ADDRESS	34.05469	-118.28892	Plan check for Title 24 only in existing Appartment builidng lighing in corridor and stari, common area 1st, 2nd and 3rd Floor only . Total area: 1,795 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24227	16041-10001-20297	1457 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.09731	-118.31598	03/23/2017 Changes to an approved set of plan. Changes include additional 11 devices Changes apply to delta 2 only and Changes address to 1457 N Van ness Ave Los Angeles CA 90028	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24228	15041-20001-07292	3978 N FREDONIA DR	90068	4	159B177    59	2380001006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.13562	-118.36608	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (17) modules and (1) inverter. Standard plan is NOT being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24229	15041-10000-35061	4000 E VERDANT ST	90039	13	159B205   474	5594016009	A2-1-K-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.13101	-118.2719	T-24, TO AN (E) COMMERCIAL BUILDING. REMOVED HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 7000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24230	17041-20001-43964	5422 N KATHERINE AVE	91401	4	171B153    32	2245024020	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	Apartment			12/07/2017 12:00:00 AM			Reviewed by Supervisor	12/21/2017 12:00:00 AM	ADDRESS	34.16937	-118.44311	Expedited plan check fee. PV1.  Install 11.7 kW PV system with 27 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24231	14041-20000-08947	1012 E PALMS BLVD	90291	11	111B149  1172	4242011027	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	33.9976	-118.45873	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN. 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24232	15041-10001-35966	5530 E VALLEY BLVD	90032	14	138A237    30	5221013039	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.07423	-118.16225	[Plan Check Only T-24] install new lightings only on (E) commercial build. Permit under 15041-10000-35966.*Note: Main Retail area under permit# 14041-10000-19956<<INSTALL (31) 2X2 DROP CEILING LIGHTS. (REFER TO #15042-10000-07113 FOR 2ND TRADE).>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24233	15041-10000-08320	850 N CAHUENGA BLVD	90038	13	144B185  1242	5533029001	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.08685	-118.32863	REVISIONS TO AN APPROVED SET OF PLANS.  SERVICE UPGRADE TO 800 AMPS.  RECONNECTING TO EXISTING PANELS.  ADDING NEW OUTDOOR LIGHTING. CHANGES CLOUDED DELTA 1 AND 3.  APPROVED SET OF PLANS PART OF THE SUBMITTAL.   PLAN CHECK FOR POWER ONLY.  **AGENT APPROVAL BY COMPANY CHECK**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24234	13041-10000-30071	14615 OXNARD STREET	91411	6	177A151    96	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			Reviewed by Supervisor	11/15/2013 12:00:00 AM	PIN	34.17979092	-118.45215041	PLAN CHECK FOR POWER AND ENERGY FOR A CAR PORT ON A FIRE STATION.  FIRE STATION PLAN CHECK UNDER 13041-10000-23043. EXPEDITED  THROUGH CITY BOND PROGRAM. TO BE AHEAD OF ALL NORMAL PLAN CHECKS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24235	15041-10000-38375	609 S ST PAUL AVE	90017	1	130-5A207  24	5143025030	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Apartment			11/13/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.05337	-118.26134	$0 permit fee per senate bill 1222.PV2 ROOF MOUNTED 174 KWAC SYSTEM. 656 MODULES AND 9 INVERTERS. 3 PHASE SYSTEM 1000VDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24236	17041-20000-33788	1531 N SUMMITRIDGE DR	90210	5	147B157   183	4355005013	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM			Reviewed by Supervisor	10/03/2017 12:00:00 AM	ADDRESS	34.09933	-118.42003	service upgrade to 600 amps.  plan check for power only.  circuits not included in plan check.permit under building combo application number 16014-30000-01426	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24237	16041-10003-38221	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM			PC Approved	09/08/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC FOR UPDATED CLASSIFICATION OF HAZARDOUS ZONES. ENGINEER PROPOSING LOWERING CLASSIFICATION TO DIV 2 AREAS AROUND EQUIPMENT AS NOTED ON PLANS. CHANGES CLOUDED ON PLANS. PC ONLY. PERMIT COVERED UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24238	18041-10000-29387	6220 W 3RD ST	90036	4	135B177   585	5509003018	[Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Apartment			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.07057	-118.3565	PC PER APPLICANT REQUEST TO RELOCATE GATE MOTORS TO EM. PANELS. TOTAL 10 RELOCATED CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24239	19041-20000-46417	5275 N CRANER AVE	91601	2	171B173   341	2416003023	CM-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Closed	06/14/2020 12:00:00 AM	ADDRESS	34.16701	-118.36925	New power and lighting for commercial space. Plan check for energy. Total square footage = 2229 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24240	18041-20000-38659	17638 W REVELLO DR pv1	90272	11	126B117   454	4416012002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.04124	-118.56077	pv1install roof mounted pv system sized 4.3KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24241	14041-20000-16949	11620 W WILSHIRE BLVD 10th floor	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	pc for title 24 energy and emergency only.  existing high rise building. new lighting fixtures on the tenth floor all circuits are existing, no new loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24242	16041-20000-05998	5266 W FOUNTAIN AVE 1-7	90029	13	144B193    52	5537012001	R3-1	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Apartment			02/19/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.09489	-118.3042	Plan check for Title 24 only. Project site is a new 3-story, 7-unit apartment building. Project scope is lighting for common areas and the outdoors. Total lighting area = 4,525 sq. ft.Note: Building application has been created under 14010-10000-03801	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24243	17041-10000-31950	10561 W PICO BLVD	90064	5	126B157   249	4315005003	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.04431	-118.42087	New Fire alarm system, (1) panel, (31) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24244	17041-20001-42813	6221 N FALLBROOK AVE	91367	3	177B097   248	2039013060	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Apartment			05/07/2019 12:00:00 AM	11/24/2020 12:00:00 AM		Permit Finaled	12/03/2020 12:00:00 AM	ADDRESS	34.18316	-118.62362	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. DELTA 4 CHANGES ONLY. ADDITION OF (2) 200A SUB PANELS, ROOF AC EQUIPMENTS, CHANGE TO RECEPTACLE KVA VALUES, CHANGE TO PANEL SCHEDULE AND SERVICE LOAD CALCS, CHANGE TO SINGLE LINE DIAGRAM, HVAC PLAN, POWER PLAN, ROOF PLAN, FEEDER SCHEDULE, AND ADDITION OF BRANCH CIRCUITS. *original*new apartment building 1600amp service.  plan check for power and energy.building application number 17010-20000-04685	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24245	14041-10000-18277	6624 S STANFORD AVE Bldg A	90001	9	102B205   105	6007017021	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			07/08/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	33.97903	-118.26285	PLANCHECK FOR POWER AND ENERGY. CHANGE OF OCCUPANCE TO FOOD TRUCK PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24246	11041-20000-26471	20235 W NORDHOFF ST	91311	12	195B113    64	2781035041	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.23201	-118.57449	Addition of new room to new warehouse building submitted on application number 11041-20000-26199.  Plan check for electrical and energy.   A new panel is to be supplied by the new main service equipment.  Plan check for electrical, and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24247	12041-20000-20699	10126-10128 W EMPYREAN WAY	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Issued	08/31/2012 12:00:00 AM	ADDRESS	34.05327	-118.40943	Install new meter banks to existing underground pull sections to supply existing feeders and existing panels for condominium units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24248	19041-10000-48896	18411 W CLARK ST	91356	3	174B125   488	2160011031	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.16989	-118.53355	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24249	12041-10000-06285	8960 N HERRICK AVE	91352	6	195B173   138	2408031901	M2-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	05/18/2012 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.23145	-118.37348	Plan check ground mounted 158 KW photovoltaic system and T24 Energy outdoor lighting at LAUSD maintenance and office site. In Methane Buffer Zone. Includes additional permit for new branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24250	17041-20000-16465	3315 N VERDUGO ROAD	90065	1	153A215   307	5457022028	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.11215	-118.23612	Plan check for installation of solar pv systems, roof-mounted on church building and detached commercial building. Two systems connecting to two separate services (one is single phase, one is three phase).Total system size: 63.3kW ungrounded. (212) 300W pv modules. (51) P600 power optimizers. (110) P300 power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24251	19041-20000-03039	16633 W VENTURA BLVD #900	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for Title 24 Energy Only in existing high-rise office Tenate Improvement. Total area: 1122 sq ft. B#19016-20000-01173	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24252	11041-10002-18921	1630 N NORTH MAIN ST Bldg #7-3rd fl	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM			PC Approved	05/09/2013 12:00:00 AM	ADDRESS	34.06682	-118.22728	SUPPLEMENTAL TO PERMIT #11041-10000-18921. change pendant lights to 2x2 and 2x4 and relocated some lightsPlan check T-24 Energy (general/emergency) lighting on 3rd floor LADWP General Services Headquarters (Bldg 7)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24253	16041-10000-18530	1071 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   183	5037026025	P-1, [Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.01106	-118.29383	TI to an (E) McDonalds, PC for T-24 only. Install new lightings, total area 2,794 sq.ft indoor + 1,700 sq.ft outdoor .  Newly connected load less than 400A.B# 16016-10000-12210	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24254	17041-10000-01258	8151 N VENTURA CANYON AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.21934	-118.42889	Plan check for power only, new Fuel Cell system rated at 1.6 MW. Fuel cell system is rated at 480 V conncected to 4.16KV (Medium Voltage) distribuition system OSHPD.  Installation on Keiser building connected exterior to OSHPD  4160 V medium voltage service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24255	15041-30000-41242	444 S FLOWER ST 45TH FLR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	Title 24 plan check only.  Total area = 12,945 sq. ft.    T.I. to entire 45th floor of commercial office building except restrooms and stairwells.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24256	13041-10000-30839	17523 W LANARK ST	91325	12	189B129    85	2201006012	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.21809	-118.51508	PV1, Install 6.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 27 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24257	11041-20000-24944	12153 N BELLANDO CT	91344	12	219B125    95	2601074005	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.29524	-118.5258	New 7.74 KW roof mounted PV system for single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24258	10041-20000-06095	18433 W ROSCOE BLVD # 102	91325	12	192B125   578	2786022035	(Q)C1-1VL, (Q)P-1VL	North Valley	Northridge			1154.02	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.22091	-118.53469	T.I. FOR 1st FLOOR MEDICAL OFFICE(2,026 SQ FT) IN UNIT # 102.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24259	16041-10000-10543	4865 N LOUISE AVE	91316	5	168B133   205	2290002003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.15843	-118.50997	$0 PERMIT FEE PER SENATE BILL 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 29.430KWdc / 25.4KWac.(90)MODULES-SPR-327NE-WHT-D(4)INVERTERS-2 SMA SB7700TL-US-22 AND 2 SMA SB5000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24260	14041-10000-06077	751 E PICO BLVD	90021	14	123A211    81	5132012016	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.03215	-118.25228	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  2166 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24261	18041-10000-42782	3566 E 3RD PL	90063	14	123A229    12	5179014060	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.03293	-118.19256	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24262	15041-20000-20074	11672 N MARIPOSA BAY LANE	91326	12	213B117   123	2701028010	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.28245	-118.56504	Plan check for a PV1 roof-mounted PV system. System size is 10.6 kWac and consists of (3) inverters, (36) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24263	11041-20000-19996	12107 W VENTURA BLVD	91604	2	162B165  1112	2367016013	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	09/20/2011 12:00:00 AM		Permit Finaled	12/09/2011 12:00:00 AM	ADDRESS	34.14368	-118.39579	T24 ENERGY/EMERGENCY LIGHTING FOR NAIL SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24264	15041-10000-15465	505 S VIRGIL AVE SUITE 202	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.0649	-118.28724	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  DENTAL OFFICE.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 1575.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24265	12041-10000-19245	6251 N BUFFALO AVE	91401	2	177B157   177	2330013002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	ADDRESS	34.18466	-118.43025	New 9.55kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24266	16041-20002-43699	9240 N JORDAN AVE	91311	12	198B105   122	2746012038	[T][Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.23844	-118.60377	[[[4/4/17 CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA 5 CHANGES. CHANGES TO INTERIOR LIGHTING, ADDITION OF FIXTURES AND WATTAGE CHANGES. INCLUDING SKYLIGHT ZONES AND CONTROLS]]](2/21/2017) changes to an approved set of plans.  changes noted delta 3.  changes include different light fixtures and changes energy forms.  this is plan check only.(((Plan check for energy only. TI to existing manufacturing building - electrical equipment wholesale. New lighting (incl. emergency) and receptacles. T24 area: indoor- 34,469sqft; outdoor- 50,138sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24267	15041-20000-25412	2727 S LA CIENEGA BLVD	90034	10	123B173   749	5065004025	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.03316	-118.37578	Installation of new roof mounted solar PV on existing commercial building.  Total system size = 14 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24268	13041-20000-28180	20905 W VENTURA BLVD	91367	3	171B109    76	2167001015	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	PIN	34.16677631	-118.58862304	FULL PC FOR FUEL DISPENSERS. HAZARDOUS LOCATION. RELOCATING 6 DISPENSERS AND 2 TURBINES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24269	10041-20000-09602	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur	YES	2088.02	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.06086	-118.27891	Plan check for new 2500 A service with new fire sprinkler pump.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24270	18041-20000-00428	4116 N ALONZO AVE	91316	5	165B129   301	2184039001	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.14533	-118.52439	Plan check for the addition of a Tesla PowerWall to an existing PV system. Service size is 400-Amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24271	18041-10000-02669	1601 N VINE ST 8th floor	90028	13	148-5A187 301	5546009154	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Issued	01/31/2018 12:00:00 AM	ADDRESS	34.09996	-118.32693	Plan check for power only of the 8th floor.  8th floor T-24 was already checked and approved.  Inspection sent applicant back for power plan check>>>>>>>>>>>>>PC for T24 only for office TI of entire 8th floor. PC includes addition of lighting and receptacles. Installing 2 new panelboards, new circuits and equipment. Total area 13217 sqft. Load under 400A. Building#17016-10000-19952.<<<<<<<<<<<<	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24272	17041-10000-35001	444 S FLOWER ST 33rd FL	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	Tenaant improvementin offices on 33rd fl. new circuits for lighting and poerplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24273	15041-20000-21844	8246 N SHOUP AVE	91304	3	192B101   655	2012023009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.21927	-118.61452	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (36) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24274	19041-20000-50542	1680 W HILL DR	90041	14	163-5A225  73	5669018002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.14356	-118.20299	PV1.  Install 3.78 kW roof mounted PV system and 13.5 kWh energy storage system.  (12) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24275	13041-20000-15480	7911 N WINNETKA AVE	91306	3	189B113   712	2107011060	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	34.21424	-118.57124	T24 FOR EXISTING SCHOOL BUILDING. SCOPE OF WORK: 903 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24276	12041-20000-14700	1716 S LA CIENEGA BLVD	90035	10	129B173  1364	5066006029	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	34.04654	-118.37607	T-24 lighting plan check only for industrial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24277	12041-20000-18257	8134 N LANKERSHIM BLVD	91605	6	189B169    16	2311005005	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.00, 1219.00	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.21861	-118.38759	Change of use from industrial to food products manufacturing.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24278	13041-20000-20165	12013 W RIALTO ST	91352	6	192B165   249	2633010019	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.22455	-118.39422	PV1 TRANSFOMERLESS SYSTEM. TOTAL SYSTEM SIZE: 4.655 KW. 19 PANELS AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24279	12041-20000-06446	5648 N MURIETTA AVE	91401	2	174B153   589	2246031009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2012 12:00:00 AM			Reviewed by Supervisor	05/15/2012 12:00:00 AM	ADDRESS	34.17355	-118.43874	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM, SFD, 4.37 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24280	18041-20000-01030	9055 N RESEDA BLVD	91324	12	198B125   272	2770004005	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.23509	-118.53635	Plan check for a PV2 roof-mounted PV system. System size is 25 kWac and consists of (2) inverters, (1) load center, and (90) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24281	19041-20000-38033	10640 N SEPULVEDA BLVD	91345	7	207B145   373	2649011037	R1P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.26382	-118.46697	Plan check for new fire alarm for adult daycare center, Total Fire alarm devices: 38 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24282	17041-20000-02165	7820 N VENTURA CANYON AVE	91402	6	189B157   734	2301012087	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.21263	-118.42858	Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with a 200A MSP.12.48kW ungrounded system. (52) EnPhase M250 microinverters. (52) 285W pv modules.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24283	18041-20000-36924	1817 S MESA ST LOT 5	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	33.7275	-118.28601	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24284	12041-10003-22730	500 W WORLD WAY Delta-Term 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	2/4/2015 Addition to work being done on the master application. Work includes revised Title 24 sheets, the addition of loads to existing panels, and the installation of (2) new panels and associated loads. Total lighting area has increased by 15,000 sq. ft.Inspection to verify that 30-day load study has been successfully completed - preliminary 7-day load study accepted at time of plan approval showing minimal loading of panel 1LA8.  (((5/14/14 plan check for revised set of plans.  Added new loads and revised Title 24. Load calcs and t24 to be verified. All changes have been clouded.)))(((CHANGES TO PERMITTED SET  OF PLANS. ORIGINAL SET OF PLANS INCLUDED NEW DISTRIBUTION BOARDS AND LOADS THAT WERE THE RESPONSIBILITY OF THE LANDLORD-LAWA. THESE ARE NOW SHOWN TO BE EXISTING AND TENANT DELTA LOADS ARE SUPPLIED FROM TENANT DISTRIBUTION BOARDS)))(((Renovation at the Delta offices at Terminal 5 at LAWA. Full plan check.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24285	14041-20000-21185	4337 N CLARINDA DR	91356	3	165B117   251	2177005014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.14869	-118.55314	PV1.  Install 6.0 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24286	19041-10000-01109	1223 W PACIFIC COAST HWY	90710	15	036B197  1115	7413003041	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Info Complete	09/26/2019 12:00:00 AM	ADDRESS	33.79009	-118.29876	FULL PLAN CHECK FOR RENOVATION AND EXPANSION OF AN EXISTING MEDICAL OFFICE (KIDNEY DIALYSIS CLINIC). SCOPE INCLUDES RELOCATION OF EXISTING PANELS, NEW CIRCUITS, EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 3733 SQ.FTB# 19016-10000-00791	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24287	16041-30000-23800	11101 S LA CIENEGA BLVD	90045	11	087B173    55	4129038025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	33.93379	-118.37023	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 12,626 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24288	13041-20000-36294	16300 W STAGG ST	91406	6	189B137    70	2205004031	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			Corrections Issued	12/31/2013 12:00:00 AM	ADDRESS	34.21296	-118.48748	Change to lighting and new receptacles on all existing circuits.  Existing Warehouse.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24289	18041-10000-19083	1435 W ROLLAND CURTIS PL	90062	8	117B193   924	5036004023	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Issued	05/22/2018 12:00:00 AM	ADDRESS	34.01652	-118.30419	PV1, ROOF MOUNTED SOLAR SYSTEM USING AC MODULES. TOTAL OF 19 MODULES, 6.84KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24290	17041-10000-14001	5999 W CENTER DR LOBBY &-EXTERIOR	90045	11	102B169   961	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	11/23/2017 12:00:00 AM	ADDRESS	33.9761	-118.38876	PC FOR ENERGY ONLY. TENANT IMPROVEMENT AT THE LOBBY AND EXTERIOR SITE WORK. CONNECTED LOAD < 400AMP. TOTAL AREA  16351 SQ FT.B #17016-10000-03500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24291	14041-10000-32467	378 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	33.93089	-118.26662	Per�Senate�Bill�No.1222, Fee cap reached, thus fee is $0.PV2, INSTALL  15.68 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMERCIAL  BUILDING. INTERCONNECT WITH MAIN SERVICE PANEL. 6 STRINGS.(2) INVERTERS:  DELTA-SOLIVIA 7.6TL (56) MODULES: LDK SOLAR LDK-280P-24	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24292	18041-10001-06636	947 S TIVERTON AVE 1-494	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			11/14/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	34.06246	-118.44303	Supplemental plan check due to revision on units's total quantity, scope includes revision on single line diagram, revision on unit's quantity and  unit's load schedule, revision on distribution load calculation, revision on service load calculation, revision on units' lighting and power floor plans. Permit shall be covered under the master plan, this is plan check only.<<Full plan check for an existing 14 story tower hotel and underground parking.Bulding Permit: 17016-10000-27541>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24293	14041-20000-34195	13606 W ROSCOE BLVD	91402	6	192B157   678	2213021013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.22145	-118.42935	Title 24 plan check only.  Total area = 569 sq. ft.T.I. to existing commercial space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24294	17041-10000-23289	2780 N LA CASTANA DR	90046	4	156B177   671	5570002029	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM			Reviewed by Supervisor	07/17/2017 12:00:00 AM	ADDRESS	34.12103	-118.35768	PLAN CHECK FOR ROOF MOUNTED PV FOR SFD. SYSTEM INCLUDES ENERGY STORAGE SYSTEM (WALL POWER PACK). PV SYSTEM SIZE 7.6KWACINCLUDING 17  MOUDULES PV SYSTEM SIZE 7.6KWACESS SYSTEM SIZED AT 5.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24295	14041-10000-03068	10326 W WALAVISTA ROAD	90064	5	123B161   749	4318033003	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			Reviewed by Supervisor	02/10/2014 12:00:00 AM	ADDRESS	34.032	-118.41211	PV1, Install 5.5 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(22) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24296	17041-20000-12734	201 N FIGUEROA ST 6TH FL-Suite 610	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM			PC Approved	04/19/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	(4/19/2016)recheck for energy to comply with 2016 energy requirements.Permit fees paid under application number 16041-10000-45275(((T.I. INTERIOR OFFICE REMODELING INCLUDING NEW FIXTURES AND RECEPTACLES. TOTAL SQ. FT. 6134)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24297	14041-10001-27524	4996 W MELROSE AVE	90004	13	141B193   606	5521001029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	PIN	34.08329075	-118.30883804	Plan check fee is $0.00 due to State Senate Bill SB1222. Additional plan check hours needed for scope of work changes - change of inverters, additional rooftop used for mounting of modules.  (((PV2, INSTALL 165 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 3-STORIES COMMERCIAL BUILDING. 2 NEW 600A MAIN SERVICE PANEL .(660) MODULES: REC PEAK ENERGY SERIES REC250PE (15) INVERTERS: ABB PV1-10.0-1-OUTD-US-S1)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24298	12041-20000-10617	4274 S MAIN ST	90011	9	114A205   310	5113031031	C2-1VL	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	02/16/2012 12:00:00 AM	PIN	34.00583482	-118.27362194	Lighting changes to existing Coing laundry ( 11041-10000-14790 )Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24299	15041-10000-16668	825 S CROCKER ST	90021	14	124-5A211  13	5146025030	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			06/03/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.03711	-118.24887	600 AMP SERVICE UPGRADE TO AN EXISTING APARTMENT BUILDING.  NEW SWITCHGEAR AND PANELS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24300	11041-10000-21721	11845 W OLYMPIC BLVD 1240W	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	PIN	34.03325831	-118.45191172	New 700 KW generator to replace exist. , (1) to (1) repacement. Reconnect exist. loads all supplied from  (1) 1200A  transfer switch.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24301	14041-20000-30404	9670 N DONNA AVE	91324	12	201B121   434	2762032029	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			PC Approved	11/03/2014 12:00:00 AM	ADDRESS	34.24691	-118.54739	modifications to approved set of plans. PC FOR CHANGES ONLY. ADDED MODULES AND INCREASE SIZE OF INVERTER. PLAN CHECK FOR ENTIRE SYSTEM AS NEW. ORIGINAL PERMIT STILL ACTIVE. SUPPLEMENTAL TO ORIGINAL SHALL BE APPLIED FOR SYSTEM AS A WHOLE. ORIGINAL PERMIT # 14041-20000-24071	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24302	19041-10000-26637	1910 S CLYDE AVE	90019	10	126B177   916	5064020029	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Apartment			07/11/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.04095	-118.36392	Plan check for Fire Alarm, Fire alarm panel has a gateway to communicate with all the devices wirelessly. the devices are battery powered. 1-facp and 16 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24303	14041-20000-29592	7726 N VANALDEN AVE	91335	3	189B121   555	2104009035	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.21119	-118.54903	PV1Using standard plan.Install roof-mounted solar array on SFD, interconnect with 200A MSP.System size: 7.2kW (3.6+3.6). Ungrounded system.41 255W pv modules across 4 strings, 2 strings per inverter (14+6)(12+9).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24304	15041-10000-39021	8631 W 3RD ST #940E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	T-24, TI TO A MEDICAL OFFICE SPACE IN A HIGHRISE BUILDING, STE #940E. SCOPE OF WORK INCLUDES ONLY NEW LIGHITNG. TOTAL SQ. FT. 1135.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24305	16041-20000-26751	10534 W SANTA MONICA BLVD 1-9	90025	5	132B157  1078	4317004016	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.05456	-118.42769	plancheck for power and energy.  new 37 unit apartment 5 story over 3 subterranean parking. [ FEES ARE BASED ON PRECUT CHECK, PLANCHECKER TO RECALCULATE].	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24306	11041-20000-08955	5400 N BALBOA BLVD #324	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1390.00, 1397.01	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	09/09/2011 12:00:00 AM	PIN	34.16914714	-118.50029545	PLAN CHECK POWER AND ENERGY FOR PEDIATRICS OFFICE (MEDICAL) #324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24307	15041-10000-25586	4151 W PROSPECT AVE BLDG A	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	T-24 ONLY TO AN (E)  2 STORY OFFICE BUILDING. SCOPE OF WORK INCLUDES ALL NEW LIGHTING IN BASEMENT, PC FOR ENERGY ONLT. TOTAL SQ. FT. 2153.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24308	18041-10000-10015	2240 S SAWTELLE BLVD	90064	11	126B153     8	4260020022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.03712	-118.44012	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24309	13041-20000-27747	20362 W SCHOENBORN ST	91306	3	192B113   530	2781028035	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.22091	-118.57726	((NUMBER OF MODULES HAVE NOT CHANGED. ZONING WAS CHECKED ON ORIGINAL APPLICATION#: 13041-20000-24220))pv1 single family dwelling. total system size 8.6 kw ac using 36 modules. 2 central inverter nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24310	11041-10000-13437	800 S HOPE ST	90017	14	129A209   202	5144020900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM			PC Approved	07/13/2011 12:00:00 AM	ADDRESS	34.0463	-118.25904	TI TO AN EXISTING OFFICE BUILDING ON THE 1ST FLOOR OF A HIGH RISE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24311	17041-10000-06399	5011-5013 N LANKERSHIM BLVD	91601	2	171B173  1230	2353011002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Closed	11/27/2018 12:00:00 AM	ADDRESS	34.16108	-118.37255	PC PC FOR POWER ONLY. SCOPE INCLUDES A NEW 600A SERVICE/ DISTRIBUTION BOARD FOR A A SHOPPING CENTER (BUILDING 3 OF 3).NOTE PLANS ARE SUBMITTED UNDER THE SAME SET OF PLANS. B#16016-30000-1037	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24312	17041-10000-12209	1430 S FEDERAL AVE	90025	11	129B149   338	4263017008	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.04685	-118.45566	PC for energy only, Outdoor Title-24. Remove HID and Install new LED fixtures. Area: 2,910 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24313	17041-10000-00091	3689 S WELLINGTON ROAD	90016	10	117B185   109	5046027008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.0202	-118.33842	PV1, INSTALLATION OF 9 KW AC ROOF-MOUNTED SYSTEM ON A SINGLE FAMILY HOUSE.(36) MODULES: SOLARWORLD SW290 MONO(36) MICROINVERTERS: ENPHASE M250-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24314	11041-20000-00519	17777 W VENTURA BLVD # 210	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	ti dental unit # 210	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24315	15041-20002-26370	1550 N GOWER ST	90028	13	147A189    19	5545008020	C4-1	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.09906	-118.32216	04/28/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to reflect field installation and to address corrections made by inspection.*****Previous Work Description*****P.C for T-24 Energy only. Total area: 4364 sq.ft. TI to a studio on a low rise bld.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24316	16041-20000-12837	9758 N COZYCROFT AVE	91311	12	201B109   323	2748005047	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Info Complete	08/23/2018 12:00:00 AM	ADDRESS	34.248	-118.58186	Plan check for power and energy. TI to industrial warehouse. Complete rewire - new 2000A service. 17,865sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24317	12041-20000-28906	2336 S CRENSHAW BLVD	90018	10	123B185   263	5060004003	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.01	Electrical	Electrical	Apartment			12/03/2012 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.0359	-118.33304	New 10-unit  apartment complex in a METHANE ZONE.  3-stories.  Full Plan Check required.  <<<Additional plan check fees required, Applicant has a pre-printed check>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24318	11041-20000-25581	6110 N VAN NUYS BLVD	91401	6	177A151    28	2240006010	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.18104	-118.44846	Expansion of of an existing one story car dealership.  Remodel includes the addition of new service, new panels, and new ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24319	17041-10000-02219	8323 N BALBOA BLVD	91325	12	192B133   235	2690023190	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.22177	-118.50286	PC FOR ENERGY. T.I. WHOLESALE RETAIL.CONNECTED LOAD <400A. TOTAL AREA 1940 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24320	15041-20001-03162	6256 N TOPANGA CANYON BLVD C-2270	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	09-01-2015 Change to approved set of plans. Changes include lighting lighting fixture flourescent in Pilates and lighting fixture decorative pendant in Studio 1. Changes apply to delta 13 only. TI FOR YOGAWORKS TOPANGA CANYON (WESTFIELD).  FIRST TIME TENANT. PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24321	19041-10000-34854	4510 W YOSEMITE WAY	90065	14	160-5A219 255	5684030011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.13304	-118.22415	(ePlan)  LADWP Community Solar Program: 5.40KWdc / 5.00KWac - 18 solar modules and 18 enphase IQ7-60-2-US micro-inverters. 1 service interconnected as a new service drop 100A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24322	10041-10000-25731	3939 S CRENSHAW BLVD Suite# E	90008	8	117B185  1015	5032002058	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.01358	-118.33646	New Fire Alarm system for a Buffalo Wild Wings restaurant. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24323	10041-20000-04140	7942 N VAN NUYS BLVD	91402	6	189B149   634	2212028020	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/08/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Closed	07/23/2010 12:00:00 AM	ADDRESS	34.21552	-118.44851	DENTAL OFFICE TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24324	14041-20000-17229	2409 W SAN FERNANDO ROAD	90065	1	150B213   594	5457009002	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.1062	-118.23944	Tittle 24 plan check on a studio from a single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24325	16041-10000-26667	6785 W SANTA MONICA BLVD	90038	4	144B185   685	5532020028	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.09087	-118.33825	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING DONUT SHOP. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 928 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24326	16041-10000-43093	9200 N OAKDALE AVE 7th Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only in exising high-rise building T.I.  separate full floor suite into multiple suites. Total area: 2007 sq ft. B#: 16016-10000-29128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24327	17041-10001-31462	10459 W TUXFORD ST	91352	7	198B177   137	2544014016	A1-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.23764	-118.35908	OFF HOUR PLAN CHECKPLAN CHECK #17041-10000-31462PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL PROPERTY. SYSTEM SIZE 6KVA INVERTER(SOLAREDGE SE7600A-US) WITH 26 MODULES(LG 395N2W-A5) WITH 26 POWER OPTIMIZERS(P405)plan checker to see notes	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24328	14041-10000-24082	7825 N ST CLAIR AVE	91605	2	189B165   768	2309014005	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.21297	-118.39999	PV1 Standard plan, 4.845KW roof-mounted system including one Solaredge SE3800A inverter, (19) Kyocera KD255GX modules and Solaredge power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24329	14041-10000-03451	8850 W VENICE BLVD	90034	10	123B169  1777		[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.03029	-118.38604	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. TI FOR SINGLE STORY FURNITURE STORE ('PLUMMERS'). SCOPE OF WORK IS < 400A WITH (E) SERVICE, (E) PANELBOARDS. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 37,848 SQ FT.. changes on plans include: automatic daylighting controls nlight certified by CEC and updated EM inverter amps (myers 2.8kw).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24330	16041-20000-21306	17822 W ERWIN ST	91316	5	177B129    91	2123025037	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.18378	-118.5219	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.38 KW.   AC MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24331	19041-20000-39756	4508 N LONGRIDGE AVE	91423	4	165B157    63	2360027009	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.1524	-118.42128	PV1.  Install 8.4 kW roof mounted grid tied PV system.  (24) modules with 7.6 kW rated inverter and 19.6 kWh energy storage system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24332	15041-20000-30388	1100 S LA BREA AVE	90019	10	132B181   952	5084011033	C2-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.0552	-118.3439	Plan check for power and Title-24 (energy).  Total area = 5,883 sq. ft. + 700 sq. ft. (outdoor)  T.I. to existing office space including service upgrade to 800 A.  New lighting, receptacles, and HVAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24333	19041-30000-14945	2029 S CENTURY PARK EAST 21st Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site are common area restrooms on the 21st floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24334	16041-20000-15658	1400 E OLYMPIC BLVD #204	90021	14	123A213   180	5130002043	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.03107	-118.2433	PLANCHECK FOR T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. SUITE 204	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24335	19041-10000-19138	10250 W SANTA MONICA BLVD AMC-#2000	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"TI IN EXISTING ""AMC"" AUDITORIUM IN SUITE #2000. NEW LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA IS 5552 SQ. FT. BLDG#19016-10000-15087"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24336	19041-30000-05034	10880 W WILSHIRE BLVD Flr 8,9,22	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to common area corridors on the 8th, 9th, and 22nd floors. Total lighting area = 4,900 sq. ft.Note: Building permit has been issued under 18016-10000-39530	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24337	14041-10001-17058	4044 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   497	5032007001	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.01588	-118.34384	0/12/2016SCOPE OF WORK INCLUDES THE ADDITION OF TWO MOTORS AND PLANS TO MATCH THE FIELD. NOTE CHANGES ON DELTA 2 ONLY. (((PC FOR POWER AND ENERGY. NEW CAR WASH . TOTAL AREA 16697 SQ.FT(INDOOR+OUTDOOR+FACADE).BUILDING APPLICATION # 13010-10000-00943.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24338	10041-20000-03918	3327 E SABINA ST Bldg C	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	NEW COMMUNITY CENTER FOR NEW APARTMENT BUILDINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24339	12041-20000-12495	22441 W OXNARD ST	91367	3	177B101   147	2039027019	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.17936	-118.61603	Photovoltaic system on roof of single family dwelling using enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24340	19041-10000-02496	6041 N VARIEL AVE	91367	3	177B105    60	2149005016	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	07/20/2021 12:00:00 AM	ADDRESS	34.1802	-118.59303	PC for a new fire alarm system for a commercial building. Scope include  812 FA devices, and 16 FA panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24341	13041-10000-32642	2503 E ANAHEIM ST	90744	15	033B217   656	7428020029	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	33.78204	-118.23117	"TITLE 24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. ""COMPLY WITH DEPARTMENT ORDER effective date 06/15/2004. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24342	18041-20001-11052	14751-14761 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.17767	-118.45487	12/12/2018 Plan check for a lost set of plans. Scope of work has remained the same.*****Original Scope of Work*****Plan check for Title 24 only in existing space lighting and receptacle in restroom and outdoor lighting. Total area: 6,140 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24343	17041-10000-30471	825 E 14TH PL	90021	14	123A211   355	5132021016	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.0295	-118.25131	TITLE 24 PLAN CHECK TO REMOVE EXISTING (6) HID FIXTURES AND REPLACE WITH LED FIXTURES. 6700 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24344	16041-10001-11834	868 W MT WASHINGTON DR	90065	1	148-5A221 127	5464014034	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM			Corrections Issued	05/06/2016 12:00:00 AM	ADDRESS	34.10036	-118.22108	05/06/2016PC only per inspectors request. Pv system using microinverters. (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))Note: Fess are $0 due to Senate Bill 12222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24345	14041-20001-01614	2463 N SOLAR DR	90046	4	153B177   324	5571032009	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.11578	-118.35405	(((EXPEDITE FEES)))PV1 LF TRANSFORMER SYSTEM. TOTAL SYSTEM SIZE 15KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24346	11041-20001-23441	10813 N ZELZAH AVE	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Approved	04/12/2012 12:00:00 AM	ADDRESS	34.26646	-118.52366	Supplemental app. Changes to lighting. Plan check for energy only. Small changes to track lighting.PERMIT ON 11041-20000-23441T.I. to existing retail space.  Install new 600A switchboard, subpanels, and branch circuits.  Install general/emergency lighting.  Plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24347	14041-10000-29167	650 S HILL ST SUITE 708--709	90014	14	129A211   215	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.04623	-118.25392	Plan check for Title 24 only for an existing building. Replacing existing light fixtures. All panels and circuits are existing to remain. Area = 2350 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24348	14041-10000-08908	13012 W LOUVRE ST	91331	7	213B161   945	2533006016	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.27683	-118.41582	PV1 TRANSFORMERLESS STRANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24349	14041-20000-15854	825 W COLORADO BLVD	90041	14	163-5A231 142	5709002012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.1404	-118.18419	pc for t24 energy only. new lighitng and new partitions in existing office space. permit to be issued from this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24350	17041-10000-23328	11401 N PORTER RANCH DR BLDG 1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Closed	05/17/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 33 unit apartment with 1600 amp 208 volt service.       Building 1 of 10.  Type III.       Building permit #17010-10000-02377	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24351	14041-20000-28718	11608 W KITTRIDGE ST	91606	2	180B169   625	2335005004	RD3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.19019	-118.38478	New roof mounted PV system with system size 4.33KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24352	19041-20000-41025	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24353	18041-20000-22809	1251 W PACIFIC COAST HWY	90744	15	036B201   708	7414023024	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/29/2018 12:00:00 AM	ADDRESS	33.79053	-118.27919	Plan check for PV roof mounted system, system size: 90kWac with 264 modules with 6 inverters(15kW) installed on commercial roof top connected supply side tap.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24354	13041-20000-29823	5250 N LANKERSHIM BLVD 3RD FLOOR	91601		171B173   367	2350018086							Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.16668	-118.37545	T24 FOR EXISTING HIGHRISE SCHOOL. SCOPE OF WORK ON THE 3RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24355	11041-20000-25286	6800 S AVALON BLVD	90001	9	102B205   234	6007019019	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Expired	01/14/2014 12:00:00 AM	PIN	33.97787513	-118.26444398	NEW 1200A SERVICEFOR EXISTING BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24356	14041-10001-21963	200 WORLD WAY Terminal 2	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Revisions to approved set.  New sheet E106 for additional dry storage room (existing lighting to be reused per applicant).  Revisions to panel schedules on sheet E602.  (((Plan check for power and lighting.  Total area = 3,921 sq. ft.T.I. to LAX terminal 2.  Installation of emergency lighting, recepticles, fire alarm system (11 notification devices), and panelboards (total connected load = 450 A))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24357	10041-20000-03373	12215 W VICTORY BLVD	91606	2	180B165   716	2322006024	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1238.00	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	12/10/2010 12:00:00 AM		Permit Finaled	01/18/2011 12:00:00 AM	ADDRESS	34.18684	-118.39918	Installtion of a transformer , a panel, and two 50 ampere 3 phase branch circuits with wiring to supply future digital display drivers.  Plan check for T-24 and electrical.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24358	11041-20000-23346	7230 N MEDICAL CENTER DR #500A	91307	3	183B097    18	2021014042	QCR-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	ADDRESS	34.20143	-118.62922	T.I.  For medical office suite 500A.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24359	18041-10000-08527	1312 N SAN FERNANDO ROAD	91340	1	147A217   270	5454035023	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	PIN	34.09610484	-118.23077691	"PC FOR REPLACMENT OF (E)  NON OPERABLE FACP  ""LIKE FOR LIKE""ALL OTHER DEVICES TO REMAIN."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24360	12041-10000-02557	5535 N TOPEKA DR	91356	3	174B121   502	2163021031	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.17192	-118.54673	Plan check for 8.36KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24361	15041-10000-09719	944 N WESTERN AVE # 190 &200	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.75113	-118.3088	alterations in an existing retail space-carter'sPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24362	19041-20002-11150	212 N ARDEN BLVD	90004	4	138B189   623	5515017008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.07504	-118.32584	09-13-2019 Changes to an approved set of plan, Changes include reomve Grounding Electrode Conductor(GEC) and update overcurrent protection 300A fuse. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24363	16041-20001-35144	9350 N DE SOTO AVE	91311	12	198B109    80	2748002071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM			PC Approved	12/01/2016 12:00:00 AM	ADDRESS	34.2406	-118.58834	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24364	15041-10000-42964	1875 CENTURY PARK EAST ste 1100	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	PIN	34.06139196	-118.41527843	PC for energy only. to an exsiting commercial bulding (offices ste 1100). Adding new lighting and power. Sq ft = 2270	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24365	16041-10001-18056	380 W WORLD WAY LVL. 3-#T04	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 2 REVISIONS. REVISED FLOOR PLAN LAYOUT. NEW LIGHTING PLAN AND UPDATED T24 DOCUMENTS. ALSO CHANGE IN CERTAIN KITCHEN EQUIPMENT. CHECKING FOR UPDATED PANEL SCHEDULES. PERMIT TO BE ISSUED FOR INCREASED IN SIZE OF SOME KITCHEN EQUIPMENT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24366	11041-10000-16687	1800 S SAWTELLE BLVD	90025	11	126B149   274	4261020001	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM			PC Approved	08/08/2011 12:00:00 AM	ADDRESS	34.04375	-118.44585	TI TO AN EXISTING RESTAURANT.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24367	11041-20000-22172	20444 W MOBERLY PL	91306	3	180B109   241	2136020020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2011 12:00:00 AM	12/16/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.19179	-118.57909	Plan check roof mounted Enphase Microinverter photovoltaic system for single family dwelling. Variance to install Enphase M215 prior to testing agency approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24368	18041-10000-15194	20539 W DEVONSHIRE ST	91311	12	204B109   127	2707013030	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.25742	-118.58075	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24369	17041-10000-20017	14516 W OTSEGO ST	91403	4	171A151   140	2263033025	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM			Reviewed by Supervisor	07/26/2017 12:00:00 AM	ADDRESS	34.16291	-118.4494	PC for new (1)Tesla Powerwall2(13.2KW) connecting to existing house panel with existing pv system.original pv permit # 16041-90000-13277	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24370	16041-10000-35432	639-659 S BROADWAY	90014	14	129A211   230	5144003040	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.04587	-118.25309	Plan check for Title 24 only in existing space in Brlington T.I. Total area: 11,750 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24371	17041-20000-21077	21650 W OXNARD ST ste 2030	91367	4			C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti to an existing comercial building.  Adding new lighting new controls to existing panels.  plan check for energy only.  suite 2030.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24372	13041-20001-23504	7480 S MCCONNELL AVE	90045	11	102B161   146	4110029027	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM			PC Approved	09/04/2013 12:00:00 AM	ADDRESS	33.97311	-118.41306	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. USING 22 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24373	12041-20004-27401	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	Supplemental application for proposed lighting design for security kiosk not under scope of original plan check.  Plan check for energy.  (((INSTALL A NEW 277/480V, 3ph, 4W, 5,000 AMP SERVICE FOR TWO NEW BUILDINGS (PARKING STRUCTURE AND BUILDING #4).  THERE ARE NO CONNECTED LOAD AT THIS TIME. ALL FUTURE TI's REQUIRE COMPLETE ELECTRICAL PLAN CHECK AND PERMIT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24374	17041-30000-46294	445 S FIGUEROA ST Suite 2970	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for Title 24 only. Project site is a portion of the 29th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,625 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24375	17041-10000-23607	3361 N ANDRITA ST LOT 3	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 3 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05785	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24376	11041-20000-00300	1901 S AVENUE OF THE STARS 18th Floor	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.05949	-118.41705	T.I. to existing high rise building.  Install general/emergency lighting in open office, lounge, and coference areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24377	19041-20000-12245	4518 N AGNES AVE	91607	2	165B165    16	2364001023	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.15278	-118.39523	addition of (1) tesla ESS 5KW to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24378	19041-10000-23858	345 N FAIRFAX AVE	90036	5	138B177   172	5527036015	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.07745	-118.3616	Energy plan check for an existing 1- story retail T.I. Scope includes new equipment and lighting with a total lighting area of of 2068-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24379	19041-20000-10640	7919 W SUNSET BLVD 2nd flr	90046	4	147B177   994	5551018008	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.09821	-118.36239	ti to an exisitng commercial building adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24380	17041-20000-22175	4513 N TYRONE AVE	91423	4	168B153   794	2265016063	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.15347	-118.44452	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.7 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24381	19041-20000-37190	236 N ARDEN BLVD	90004	4	138B189   493	5515017003	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.07572	-118.32584	PV1 PLAN CHECK FOR NEW ROOF PV ON EXISTING SFD AND A 13.5 ENERGY STORAGE SYSTEM. SYSTEM SIZE IS 13.86 KW DC/12.576 KW AC. SCOPE OF WORK CONSISTS OF (42) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, A 13.5 KWH BATTERY, AND A SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24382	18041-10000-12456	2515 W BEVERLY BLVD	90057	13	136-5A203 121	5157009027	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.06907	-118.27536	METHANE MITIGATION SYSTEM (LEVEL 5) . SCOPE INCLUDES 28 SENSORS AND 8 ADDITIONAL DEVICES LOCATED ON THE LOWEST OCCUPIED SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24383	13041-10000-27801	11661 W SAN VICENTE BLVD 10TH FLR	90049	11	132B145   485	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.05407	-118.46431	TITLE-24 PLAN CHECK ONLY FOR HIGH-RISE BUILDING. ADDING & REPLACING MORE EFFICIENT LUMINAIRES. TOTAL AREA IS TO BE 10,057 SF. EMERGENCY LIGHTING IS EXISTING AND WILL REMAIN EXISTING, NO WORK WILL BE DONE TO THE EMERGENCY LIGHTING PER C-10 CONTRACTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24384	18041-20000-35415	15860 W DARTFORD WAY	91403	5	159B141   320	2280025014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Issued	10/03/2018 12:00:00 AM	ADDRESS	34.13247	-118.47933	PV1.  Install 11.16 kW roof mounted grid tied PV system.  (31) AC modules.  Derated main breaker rating.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24385	19041-20000-37405	1781 W SUNNY HEIGHTS DR	90065	1	150A221    39	5464004050	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.10674	-118.22095	Plan check for new Energy Storage System, install 2 Telsa Battery(13.5KWh), Energy Storage size: 27KWh installed into existing PV system and new sub panels	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24386	15041-20000-00441	22832 W STRATHERN ST	91304	12	189B097   441	2014011005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2015 12:00:00 AM			PC Approved	01/07/2015 12:00:00 AM	ADDRESS	34.21533	-118.62476	Change from previously approved plans (14041-20000-31377).  Change in warning label plan.  Note: Permit is under the previously approved plans.*****Previous Description*****Roof mounted PV system with Enphase model M215-60-2LL-S22.  Total system size 4.6 KW.Note: the solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24387	13041-10000-11115	1530 N HILLHURST AVE	90027	4	147B197   561	5542006022	[Q]C2-2D	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.09931	-118.28724	PLAN CHECK FOR FIRE ALARM SYSTEM ON A TWO STORY BUILDING. 150 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24388	12041-10000-19311	6136 E BUENA VISTA TER	90042	14	160-5A231 197	5481006008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2012 12:00:00 AM			Plans on Hold	08/23/2012 12:00:00 AM	ADDRESS	34.13232	-118.18804	Plan check for new roof mounted 9.60KW photovoltaic system. Single family dwelling.  <<<Per Applicant's Request HOLD plan Do not assign.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24389	12041-10000-14759	801 S HOPE ST	90017	9	129A209   178	5144020195	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.04656	-118.25938	New 22-stories  high-rise mixed-use building with one 4,000 amp service for house/commercial loads(B1,B2, 1ST THRU 4TH FLS and a 3000amp service for residential units ( 290units 5th THRU  22nd FLOORS)-both services are 277V/480V 3PH 4W.  Fees are calculated to match applicants pre-cut check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24390	19041-10000-52374	5750 W WILSHIRE BLVD 4TH FLOOR	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Info Complete	04/22/2020 12:00:00 AM	ADDRESS	34.06227	-118.3542	FULL PLAN CHECK FOR ENERGY AND POWER. SCOPE OF WORK INCLUDES  ADDING NEW ELECTRICAL CIRCUITS, PANELS AND LOAD TO AN EXISTING SPACE ON THE  4TH FLOOR. TOTAL SQUARE FOOTAGE: 47,975 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24391	14041-20000-13208	3901 N EAGLE ROCK BLVD 1-16	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Apartment			05/16/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.11925	-118.23127	CONSTRUCTION OF NEW MULTI FAMILY DWELLING. TOTAL OF 16 UNITS. PC FOR POWER AND ENERGY. THIS PC IS FOR BUILDING B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24392	14041-20000-08514	6801 W HOLLYWOOD BLVD #170	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I. to existing retail space for Shoe Palace.  Install new general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24393	17041-10000-13281	6330 W SAN VICENTE BLVD 310	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.06116	-118.36804	PC FOR POWER AND ENERGY. T.I TO AN EXISTING MEDICALOFFICE. CONNECTED LOA < 400 AMP. TOTAL AREA 1894 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24394	16041-10000-35204	5790 W JEFFERSON BLVD	90016	10	120B173   842	4205031011	(Q)M1-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	01/18/2023 12:00:00 AM	ADDRESS	34.02643	-118.37606	PC FOR 16-STOEY HIGH RISE BUILDING WITH OFFICE SPACES AND 2 LEVELS OF PARKING UNDERGROUND. PC FOR POWER AND ENERGY.(REF B# 14010-10000-00780)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24395	19041-20001-35364	7650 N RESEDA BLVD	91335	12	186B125    45	2119001065	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			Reviewed by Supervisor	09/17/2019 12:00:00 AM	ADDRESS	34.2098	-118.53586	Expedite per applicant request Plan check for PV roof mounted system, PV system size: 12.96KW with 32 PV Modules and 1 inverter(10KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24396	19041-20000-26976	4835 N MARY ELLEN AVE	91423	4	168B157   258	2358016016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.15871	-118.41938	PV1.  Install 11.16 kW roof mounted grid tied PV system.  (31)  AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24397	13041-20000-25642	18946 W TUBA ST	91324	12	204B121   178	2729003022	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.2566	-118.54663	New 2.5kw DC PV System.  System uses ENPHASE M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24398	12041-20000-19028	555 S FLOWER ST SUITE #-3300	90071	9	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.05048	-118.25755	T.I. to a high rise building on the 33rd floor in suite 3300.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24399	10041-10000-11557	5081 E ALHAMBRA AVE	90032	14	138A233   279	5216025011	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	10/20/2010 12:00:00 AM	ADDRESS	34.0712	-118.1755	Change of use from commercial to a work-living building. (The Storage & Work area  portion is allready plan checked for T24 and permitted #09041-10001-10068)  EPC is requested per inspector Mitchell request. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24400	14041-10000-08289	15317 W VANOWEN ST	91406	6	183B145   747	2234024037	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Issued	01/13/2015 12:00:00 AM	ADDRESS	34.1941	-118.46692	REPLACING EXISTING 1000A PULL SECTION AND NEW DISTRIBUTION EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24401	19041-20001-14163	14150 W VAN NUYS BLVD #105	91331	6	201B153    32	2645021001	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Issued	09/11/2019 12:00:00 AM	ADDRESS	34.25162	-118.4416	09-11-2019 Changes to an approved set of plans, Changes include change manufacture PV Modules to China Sunenergy CSUN370-72MH(40). Update PV system size: 14.8 KW DC, 13.14KW AC Fees $21.25 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24402	14041-20000-17155	1154 N HIGHLAND AVE	90038	4	144B185   509	5532020002	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.09225	-118.3384	Tittle 24 plan check only on a 1895 SQ feet  partial area from a commercial building under permit #: 14041-90000-14333	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24403	14041-10000-14869	12682 W SANDHILL LANE # 1 -3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	33.97708	-118.41507	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24404	10041-20000-07355	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Public Safety Only			04/21/2010 12:00:00 AM	04/21/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	34.05855	-118.23671	Install air sampling system and connect to main fire control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24405	19041-20000-19105	21700 W OXNARD ST STE 580	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.17901	-118.60179	T24 ONLY PLAN CHECK, INDOOR FLOURESCENT LIGHTS REPLACED WITH LED. TOTAL SQUARE FOOTAGE = 9,874SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24406	16041-10000-19878	905 W VENICE BLVD	90291	11	108B149   598	4241035027	R3-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	PIN	33.99347261	-118.45445646	FULL PC FOR POWER AND ENERGY FOR AN EXISTING MEDICAL CLINIC; ADDITION OF NEW EXAM ROOMS AND NEW TEAM ROOMS; NEW EXTERIOR COURTYARD; RELOCATION OF ACCESSIBLE PARKING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR EXAM ROOMS/RECEPTION/CORRIDOR SPACES. TOTAL AFFECTED AREA IS 4047 SQ. FT.NOTE TO PLAN CHECKER:  APPLICANT CLAIMS MEDICAL CLINIC IS AN OSHPD 3, BUT BUILDING DOES NOT SPECIFY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24407	17041-10000-17555	10250 W SANTA MONICA BLVD # 1880	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check, first tenant-Maje- at Century City Mall, 1321 sq. ft,	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24408	15041-10000-22890	3124 W SWAN PL	90026	1	154-5A219 211	5472010012	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/27/2015 12:00:00 AM	ADDRESS	34.09204	-118.27022	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.4KW INTERCONNECTED WITH MSP.  (44) KYOCERA 2656ZPA MODULES(2) ABB PVI-4200 INVERTERS ((  SUBMITTAL PER APPLICANT)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24409	14041-20000-13641	12675 N HUNNEWELL AVE	91342	7	219B161    70	2525002027	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.30055	-118.4191	PV1.  Install 5.1 kW roof-mounted utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24410	17041-20000-25482	2001 N SOTO ST 101	90032	1	135A227     2	5211021006	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.06624	-118.19673	Plan check for energy only. TI - changing data room to office/MRI research rooms. New lighting (incl. emergency) - 869sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24411	13041-10000-10693	542 N PALISADES DR	90272	11	129B117   107	4419015025	(Q)C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.04597	-118.55191	T24 FOR TRAINING CENTER. 1050 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24412	14041-10000-18968	8500 W BEVERLY BLVD #678A	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR T24 only. TAILORED METHOD. emergency lighting installed. TOTAL AREA  1646 SQ FT.  TRUE RELIGION SUITE #678A. changes on plans include T24 controls clarification, 2A supplementary ocpd.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24413	15041-10000-24337	2100 W SLAUSON AVE	90047	8	108B189  1360	6001003007	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Expired	07/13/2018 12:00:00 AM	ADDRESS	33.98897	-118.31589	PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE TO TIRE SHOP. SERVICE  EQUIPMENT IS EXISTING. HAZ LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24414	14041-10000-06326	6375 N FIGUEROA ST	90042	14	154-5A231 146	5493003027	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.11762	-118.18368	TENANT IMPROVEMENT IN RETAIL/OFFICE SPACE ;1ST FLOOR OF A 2-STORIES BUILDINGPLAN CHK IS FOR TITLE 24 ; PERMIT ON 13041-10000-31069 / 234 N HAMLET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24415	12041-20000-22959	801 S GRAND AVE #400	90017	9	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.04581	-118.25842	Install lighting fixtures in two conferencence rooms in suit 400.  T-24 lighting plan check for two conference rooms in suite 400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24416	10041-20000-13443	5250 N HARMONY AVE	91601	2	171B177   416	2416010041	[Q]R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			07/14/2010 12:00:00 AM			Reviewed by Supervisor	08/09/2010 12:00:00 AM	ADDRESS	34.16637	-118.36632	plan check new installation for 64.4KW photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24417	19041-20000-41186	2758 W ESTARA AVE	90065	1	153A215   208	5457021003	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.11335	-118.23693	PV roof mounted system, PV system size: 11.56KW DC, 10.815KW AC with 34 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24418	17041-20000-45754	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.24143	-118.56249	Plan check for energy only. TI to ground floor offices. New lighting (incl. emergency) - 1,949sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24419	17041-20000-01430	2694 W JAMES M. WOOD BLVD	90006	1	132A201   210	5077028002	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.05575	-118.28671	pv2install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24420	18041-30001-44365	15273 W SUNSET BLVD 5-113A	90272	11	129B125   863	4410007009						2625.01	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.04688	-118.52497	02/21/2019 Changes to an approved set of plans. Changes have been made to the lighting and power floor plans and changes have been reflected onto the Title 24 compliance forms.*****Original Scope of Work*****ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24421	17041-20000-15853	523 N ARDEN BLVD	90004	4	141B189  1037	5523014017	R1-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.07961	-118.32615	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.7 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24422	12041-20000-22599	12131 W BURBANK BLVD	91607	2	174B165   722	2340025035	R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.17236	-118.39764	fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24423	16041-20000-16166	3502 S TROUSDALE PKWY B5,B4,B15	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM			PC Info Complete	05/10/2016 12:00:00 AM	ADDRESS	34.02175	-118.28408	CHANGE OF USE FROM OFFICE TO CLASSROOM B OCCUPANCY.  TI TO AN EXISTING 2 STORY COMMERCIAL BUILDING .  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 2442.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24424	15041-20000-34157	12827 N BORDEN AVE	91342	7	222B153   583	2508007025	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/07/2015 12:00:00 AM	ADDRESS	34.30327	-118.43795	PV1, roof mtd. solar system 5.565 kW. (21) modules #KU2656ZPA, (1) inverter PVI-5000-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24425	18041-10000-33435	1951 N MARIANNA AVE 1941-1951	90032	14	135A233    39	5223002005	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.06532	-118.17865	Energy plan check for a commercial building; scope includes new lighting and equipment with a total area of 40,906-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24426	19041-10000-09167	1045 S SANTEE ST #225	90015	14	126A209   255	5145020009	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Issued	03/14/2019 12:00:00 AM	ADDRESS	34.03803	-118.25612	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24427	12041-10000-17749	6263 W DE LONGPRE AVE	90028	13	147A189   139	5546023031	R4-2D	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	07/30/2012 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.09628	-118.32592	in a parking lot , installing 4ea post-supported luminairesplan check is for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24428	10041-20000-20464	11540 N SEPULVEDA BLVD	91345	7	213B145     9	2664006***	A2-1, RE20-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1066.06	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.27973	-118.4687	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR INTERIOR REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24429	14041-10000-32760	2330 W RIPPLE ST	90039	13	150A211    79	5437032015	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.10672	-118.25294	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 16872 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24430	11041-10000-17138	3450 W WILSHIRE BLVD	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			Corrections Issued	08/12/2011 12:00:00 AM	ADDRESS	34.06151	-118.29958	T.I for 9th floor of a high rise bldg. Title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24431	15041-20000-23267	22838 W ROSCOE BLVD	91304	12	192B097   475	2014003012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.21917	-118.62493	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24432	17041-20001-03940	21650 W OXNARD ST GROUND FLR	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.17901	-118.60107	Replacing existing UPS with new UPS.  Plan check for power per inspector's comments.  SLD sheet only.  Design-build plans.  Backup loads served are non-life safety per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24433	10041-20000-01174	905 W 35TH ST Bldg E	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.02298	-118.28666	"All revisions dated after 12/17/08 to approved plans with PCIS #08041-20000-21027. (New Building ""E"" at USC Campus (CNTV PHASE II).)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24434	16041-10003-16332	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM			PC Approved	09/02/2016 12:00:00 AM	ADDRESS	33.76597	-118.28407	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE DIFFERENT MODULE TYPE AND NEW STRING CONNECTIONS. CHANGE IN AC INTERCONNECTIONS. CHANGE IN LAYOUT - NEW FD APPROVAL NEEDED.  TOTAL SYSTEM NOW USES 21853 MODULES AND 64 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24435	16041-20000-02288	6225 W CENTURY BLVD 1st Floor	90045	11	090B165     5	4124026005	C2-2, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	33.9457	-118.39456	TI to existing high rise commercial building (hotel). Plan check for energy only. Adding new lighting including emergency lights. Total sqft. 40,872Note: Building applications have created under 15016-10000-09745 and 15016-10000-09747	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24436	14041-20000-06522	11823 W DARLINGTON AVE 1-10	90049	11	129B145   343	4265017034	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.05085	-118.46669	14 UNITS APARTMENT BUILDING  VARIANCE ON FILE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24437	19041-20001-42155	10558 W LINDBROOK DR	90024	5	135B153   495	4360018010	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM			Reviewed by Supervisor	10/31/2019 12:00:00 AM	ADDRESS	34.06345	-118.43374	Expedit per applicant request. Plan check for PV roof mounted and Energy Storage system, PV system size: 7.26KW DC, 7.6KW AC with 22 PV Moduels and 1 inverter(7.6KW) and Sonnen Eco  battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24438	15041-20000-12703	1560 W SAN FERNANDO ROAD	90065	1	147A217   196	5454035036	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Issued	04/28/2015 12:00:00 AM	ADDRESS	34.0976	-118.23299	Plan check for Title-24 only.  Total area = 2,487 sq. ft.  T.I. to existing commercial low rise building.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24439	16041-10002-45417	1120 W WASHINGTON BLVD	90007	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.03867	-118.28211	PC FOR CHANGES TO APPROVED SET OF PLANS FOR A NEW MEDICAL BUILDING UNDER CLOUDED AREAS, DELTA 4. SCOPE INCLUDES NEW FEEDER FOR UPS SYSTEM WITH ADDITIONAL DISTRIBUTION PANEL AND RELOCATION OF EQUIPMENT. LOADS TO UPS SYSTEMS IS FOR FUTURE INSTALLATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24440	18041-20002-04334	8353 W GRAND VIEW DR	90046	4	148-5A175  22	5556019020	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.10318	-118.37269	04-13-2018 Changes to an approved set of plan. Changes include remove battery back up system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24441	19041-20000-52953	1511 S BROCKTON AVE	90025	11	126B145   650	4263035003	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.02	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.04095	-118.46101	FULL PC FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO A DENTAL OFFICE SPACE. TOTAL SQ. FT. 2500.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24442	19041-20000-35590	11539 N DELLMONT DR	91042	7	213B197    59	2552041022	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.27809	-118.2964	PV1.  Install 11.2 kW roof mounted grid tied PV system.  (35) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24443	15041-20000-03790	15150 W ROXFORD ST	91342	7	228B145   450	2502004038	C2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Apartment			02/09/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.31841	-118.46333	NEW 33 UNIT APARTMENT. PC FOR POWER AND ENERGY. FIRE ALARM VARIANCE HAS BEEN FILED. PC FOR 2008 BUILDING EFFICIENCY STANDARDS DUE TO DATE OF BUILDING SUBMITTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24444	12041-10000-07983	3101 W OLYMPIC BLVD	90006	10	129B193   269	5080024014	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.05277	-118.30336	(E) RESTAURANT INTERIOR REMODELING; NEW INTERIOR PARTITION WALL; (N) ADA COMP. RESTROOMS; REPLACE (E) LIGHT FIXTURES TO ENERGY SAVING FIX.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24445	17041-20000-34811	226 N BERENDO ST	90004	13	138B197   505	5518026006	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM			PC Info Complete	11/17/2017 12:00:00 AM	ADDRESS	34.07534	-118.29403	Plan check for power and energy. New 4-story, 9-unit apartment building over 1-level subterranian parking garage. 400A 120/240 1ph 3w service, and 200A 120/240 3ph 4w service. 7 typical units. T24 area - 12,822sqft.Note: Building application has been generated under 17010-10000-00432	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24446	12041-10000-16060	9301 N TAMPA AVE 30	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM			PC Approved	07/11/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check T24 Energy/Emergency lighting for retail space #30 HOT TOPIC T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24447	16041-10001-13949	3377 W WILSHIRE BLVD A1	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.06193	-118.29742	7/25/16: Changes to approved set pertaining lighting layout. This is Plan check only.<T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM A STORAGE SPACE TO A NEW RESTAURANT. SCOPE INCLUDES NEW LIGHTS RECEPTACLES. TOTAL AFFECTED AREA IS 1471 SQ. FT.* Permit was issued under 16041-10000-11058>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24448	16041-20000-31896	1464 S CENTRAL AVE	90021	14	121-5A211 168	5130011003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.02753	-118.24752	TI TO AN EXISTING COMMERCIAL BUILDING 3 STORIES..  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS A AND B.  NEWLY CONNECTED LOAD < 400 AMPS. PLAN CHECK FOR ENERGY AND EM LIGHITNG.  TOTAL SQUARE FOOTAGE 5966.  SCOPE OF WORK IS FOR FIRST FLOOR  SPACE A AND B AND CORRIDORS ON THE SECOND AND THIRD FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24449	16041-20000-13092	11320 W MAGNOLIA BLVD	91601	2	171B173   672	2353002008	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.16469	-118.37817	Plan check for energy only. TI to existing office. New lighting. 1,850sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24450	16041-10001-07235	9321 N LOUISE AVE	91325	12	198B133   252	2766014005	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.24002	-118.51146	expedite per applicantPV1, rooftop solar installation 11.5kW system(43) SPR327NE-WHT-D(1) SPR-7700TL-US(1) SPR-3800TL-US(1) 125A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24451	10041-20000-25749	9725 N LAUREL CANYON BLVD	91331	6	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.20	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.24604	-118.41908	T.I. to a Target store.  Install transformer, motors, panels, and branch circuits.  Install general lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24452	16041-10000-41714	12100 W WILSHIRE BLVD 15th FL RR	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.0438	-118.46755	Plan check for Title 24 only in exising rest room on 15th Floor. Totla area: 402 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24453	17041-10002-08208	929 W JEFFERSON BLVD #1670	90007	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	PC FOR POWER SYSTEM FOR FIRST TIME TI. PERMIT ALREADY ISSUED. THIS APPLICATION PERMIT WILL COVER CHANGES OF ADDRESS TO ADD UNIT NUMBER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24454	13041-10000-16662	6801 S PARK TER STE550	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	33.97698	-118.39328	permit to be pulled at EPC counter.pc for energy only. TI TO EXISTING OFFICE. GENERATOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24455	10041-10002-11210	3450 S WATT WAY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM			PC Approved	08/27/2010 12:00:00 AM	ADDRESS	34.02275	-118.28604	Change the priviously approved paln. Add CSS Classroom Studio area to an existing permit. Plan check for T24 and emergency lights. (((((((((((((((( T-24 and emergency lighting plan check for remodeled portion of the Thornton School of Music.  Inspector, please verify listing of the Wenger Rooms.))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24456	16041-20000-12287	601 W 5TH ST 1150	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,019 sq. ft.Note: Building permit has been pulled under 16016-10000-05265	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24457	17041-10000-24706	2714 N ST GEORGE ST	90027	4	150B201   490	5433024004	R2-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.10838	-118.2753	Plan check for Title 24 only in existing space, remove HID outdoor fixtures and replace with new LED fixtures. Total area: 8350 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24458	14041-20000-26447	1420 S LAWRENCE ST	90021	14	120A215    67	5167017026	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	PIN	34.02437722	-118.23676333	pc for power only. new 800A service upgrade. load calc provided and fault current. 120/240 3P4W delta	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24459	13041-10000-25952	380 WORLD WAY T56	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			Corrections Issued	09/19/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 for a storage at LAX. reduction of lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24460	14041-10000-31519	2180 S WESTWOOD BLVD suite 2p	90025	5	126B157   253	4321012071	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.04421	-118.4318	Title 24 plan check only.  Total area = 1,087 sq. ft.T.I. to existing commercial space including lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24461	16041-10000-07758	501 W EL SEGUNDO BLVD #A	90061	15	081B201   259	6132002024	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	PIN	33.91663801	-118.28317828	Full PC for a commercial building (7-eleven retail store). First time tenant. Existing service 400 A service. Total sq ft = 2079	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24462	15041-20000-17093	1055 W 7TH ST 2nd Floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.0507	-118.26334	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total indoor lighting area = 11,010 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24463	16041-20000-45136	9301 N TAMPA AVE Suite 126	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	04/10/2017 12:00:00 AM		Issued	04/10/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 4,494 sq. ft.Note: Building application has been generated under 16016-20000-30771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24464	16041-10000-24026	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Issued	08/08/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	TEMPORARY POWER SERVICE SIZE 2000A. FOR BEVERLY HILLS MALL.INCLUDING ONE 1000A AND ONE 400 A SWITCHGEAR TO FEED THE EXISTING TENANTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24465	13041-20000-19137	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	33.98489	-118.42552	RENOVATION OF 2 WORK ROOMS. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 898 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24466	18041-10000-36433	5955 N LANKERSHIM BLVD	91601	2	177B169   914	2338009018	RD2-1, [T][Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.17886	-118.3833	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24467	14041-20001-33170	23355 W CALIFA ST	91367	3	174B093    11	2041006014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.17683	-118.63612	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6.24kW. Ungrounded system.26 EnPhase M250 microinverters with 26 270W pv modules across 2 strings (12+14).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24468	18041-10000-29196	15345 W SAN FERNANDO MISSION BLVD	91345	7	210B145   116	2664007901	PF-1XL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.27234	-118.46679	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24469	19041-20000-30911	1518 N CAHUENGA BLVD	90028	13	147A187    79	5546012007	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	11/06/2021 12:00:00 AM	ADDRESS	34.09857	-118.32936	Power and lighting for restaurant TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24470	14041-10000-21015	886 S HILGARD AVE 1-58	90024	5	135B153   428	4360007029	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Public Safety Only			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.06427	-118.44082	REPLACING FIRE WARNING SYSTEM IN AN APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24471	17041-10000-08630	20650 W PRAIRIE ST	91311	12	198B109    90	2748041025	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Issued	03/17/2017 12:00:00 AM	ADDRESS	34.24003	-118.58407	PC for energy only, outdoor. Removing HID fixutres and replacing them with New LED ones. Area: 30,290 sq ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24472	18041-10000-36672	1133 S HOPE ST	90015	14	127-5A207 285	5138014113	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.0416	-118.26394	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES WITH ABOUT 1,282 FA DEVICES AND 11 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24473	19041-10000-16714	3717 E WHITTIER BLVD	90023	14	120A229    10	5188008024	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	05/03/2020 12:00:00 AM	ADDRESS	34.02455	-118.19324	PC FOR ENERGY ONLY, SCOPE: CHANGE OF USE FROM STORE, AND CAFE INTO A RESTURANT, AREA OF SCOPE 2,938SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24474	17041-20003-34917	19550 W CANTARA ST	91335	3	192B117   913	2105002008	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM			PC Approved	11/22/2017 12:00:00 AM	ADDRESS	34.21901	-118.55965	Revisions to approved set of plans.  Change of interconnection of solar PV system from main service panel to (N) subpanel attached to main house.  $0 plan check fee per State Senate Bill SB 1222. (((Plan check for solar pv system, roof-mounted array on SFD.12kW ungrounded system [(2) 6kW]. (60) 265W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24475	17041-20000-20396	13207 N GLADSTONE AVE A-B	91342	7	225B157   700	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.31086	-118.4288	Plan check for fire alarm system. New fire alarm system for commercial retail building. 1 FACP. 66 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24476	10041-10000-10029	6100 W CENTER DR #825	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM			PC Info Complete	05/26/2010 12:00:00 AM	ADDRESS	33.97733	-118.3922	TI IN AN EXISTING OFFICE AREA IN SUITE # 825.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24477	10041-10000-24444	7360 W BEVERLY BLVD # 105	90036	5	138B181   460	5512014002	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	02/03/2011 12:00:00 AM	ADDRESS	34.07597	-118.35026	IN AN EXISTING RESTAURANT, TENANT IMPROVEMENTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24478	14041-10000-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	PC FOR POWER AND ENERGY. WORK WITHIN EXISTING PARKING LEVELS, REPLACE DWP SERVICE, ADD DISTRIBUTION FOR NEW TENANTS, ADD AND REPLACE PKG LIGHTING. TOTAL AREA 1423101 SQ FT. PHASE 3.PLAN CHECKER RE-VERIFY THE FEES<<<EVERYTHNG ON PAGES 3.E.04.07 AND AFTER  ARE NEW JOBS AND BEFORE  THIS PAGE IS  EXISTIN AND DOING SOME ADDING AND REPLACING.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24479	14041-10000-32899	3150 W SAN FERNANDO ROAD Suite 2	90065	13	153B209   408	5458002013	[Q]C2-1VL-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Issued	12/04/2014 12:00:00 AM	ADDRESS	34.11582	-118.24713	Plan check for Title 24 only. Project site is a commercial space (not first time tenant; space will stay commercial). Total lighting area = 5,388 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24480	15041-10001-12756	1278 S VELASCO ST	90023	14	118-5A225 171	5190019006	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2015 12:00:00 AM			PC Approved	05/04/2015 12:00:00 AM	ADDRESS	34.01925	-118.20506	PV1 INSTALLATION OF 4.32 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE  FAMILY HOUSE, TIE WITH THE MAIN SERVICE PANEL.(16)MODULES:(1) INVERTER:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24481	13041-20000-03240	5077 N LANKERSHIM BLVD 1-130	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.1626	-118.37361	New 4-story, mixed use building.  3000 amp service.  Full Plan Check.  Variance to separate fire alarm plans has been filed.  (((Customer has a pre-printed check, fees may need to be verified before issuing permit.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24482	10041-20000-04383	615 W 36TH ST TROJAN-HALL	90007	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	06/01/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	PIN	34.02192429	-118.28551249	WORKING IN MECHANICAL ROOM OF A BUILDING INSTALLING LIGHTING, POWER AND 9 SMALL MOTORS.  THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24483	14041-10000-17086	12355 W MONTAGUE ST	91331	7	204B165   212	2537005017	M2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.25413	-118.4026	PC FOR FULL PLAN CHECK PER APPLICANT REQUEST. USE OF LAND FOR PARKING LOT AND  TRUCK STORAGE.TOTAL AREA 104000SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24484	17041-20000-33252	8106 N LANKERSHIM BLVD	91605	6	189B169    62	2311005040	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.2179	-118.38758	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,925 sq. ft.Note: Building application has been generated under 17016-30000-25250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24485	16041-20000-31875	14857 W NAVARRE WAY	91342	7	219B149   648	2611007050	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29544	-118.45514	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24486	10041-10001-08726	705 W 9TH ST 1st floor	90017		129A207   265	5144021040							Electrical	Electrical	Apartment			06/16/2010 12:00:00 AM			PC Approved	06/16/2010 12:00:00 AM	ADDRESS	34.04607	-118.2616	Change the approved plan. Addition of the storage room. plan check for T24.  (((((((((Remodel of the common area on the 1st floor of  an appartment building.  Plan check for T24 and emergency.))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24487	12041-10000-13237	603 S SPRING ST	90014	14	129A211   220	5144002017	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Approved	08/01/2012 12:00:00 AM	ADDRESS	34.04585	-118.25136	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR STARBUCK COFFEE SHOP ON THE GROUND FLOOR OF AN HIGH RISE BUILDING. NO EMERGERNCY GENERATOR IN BUILDING. USING 120 BATTERY BACK UP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24488	14041-20000-34670	523 W 6TH ST 1211-2-1206	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI TO SUITE 1211-1212. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24489	19041-20000-31309	832 S MARIPOSA AVE	90005	10	132B197   698	5094017003	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	11/04/2022 12:00:00 AM	PIN	34.05648561	-118.29838386	FULL PLAN CHECK FOR NEW 3000A SERVICE, (3) PANELS OVER 1200A, (27) PANELS 601-1200A, (1) PANEL 201-600A, (110) PANELS 0-200A, (12) EQUIPMENTS 5.1-20 HP-KVA, (103) EQUIPMENTS 3.1-5 HP-KVA, (3) EQUIPMENTS 20.1-50 HP-KVA, (1936) BRANCH CIRCUITS, (101) SMOKE DETECTORS, AND TOTAL SQUARE FOOTAGE FOR T24 IS 141,718 SFBuilding permit filed under 18010-10000-00378.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24490	15041-20000-39533	635 S MORENO AVE	90049	11	126B137    57	4264005017	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.04412	-118.48534	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.57 KW(37) SUNPOWER SPR-X21-345(1) SB7000TL-US-22 240V(1) SB5000TL-US-22 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24491	16041-10000-43345	6723 N VAN NUYS BLVD	91405	6	180B149   136	2236010001	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.19269	-118.44905	CHANGE OF USE TO GYM. TWO STORY FITNESS CLUB. PC FOR POWER AND ENERGY. NEW 800A SERVICE AND ASSOCIATED GYM EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24492	14041-10000-09139	461 W 9TH ST	90731	15	015B201   382	7455008002	C2-1VL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	33.73592	-118.28701	fulla plan chek for changing a church to charter school. total area 40,000 sq ft(indoor+ outdoor). # of divices per applicant count.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24493	19041-10000-10311	6600 N TOPANGA CANYON BLVD 1002	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Issued	05/22/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Energy plan check for a retail T.I located in the Mall. Scope inlcudes new lighting and equipment with a total area of 2731-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24494	14041-10000-17438	11800 N FOOTHILL BLVD	91040	7	210B165   540	2528002901	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District, Pacoima	YES	9800.21	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.273	-118.39313	Title 24 plan check only (tailored method).  Total area = 1,325 sq. ft.TI for existing retail store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24495	12041-20000-19280	10433 W MCBROOM ST	91040	2	207B177   137	2528031010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.26225	-118.35753	Photovoltaic system on the roof of SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24496	17041-20002-19660	11500 W CANTON DR	91604	2	159B169   378	2377016014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.13274	-118.38388	[[10/10/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES ARE CLOUDED. PLANCHECK ONLY. RELOCATIING DISCONNECT]]]Plan check for roof-mounted solar pv system with AC coupled battery backup system.10.4kW ungrounded system. (37) 325W pv modules. (2) 5kW Tesla Powerwalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24497	18041-20000-41387	6316 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029022	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.18578	-118.60514	New 600A fuse and feeder connected to (E) distribution equipment for future tenant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24498	14041-10000-13545	8421 N TELFAIR AVE	91352	6	192B169   417	2632023039	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.22309	-118.38288	Remove HID light fixture and replace with new flourescent	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24499	17041-10000-45868	815 N HARPER AVE	90046	5	141B173   148	5529010027	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.08589	-118.36927	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.96KWdc / 3.8KWac.(8)LG 360Q1C-A5(8)OPTIMIZERS-P370 SOLAREDGE(1)INVERTER-SOLAREDGE 3.8H	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24500	17041-10000-01969	11901 W OLYMPIC BLVD	90064	11	123B149   504	4259023016	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.03287	-118.45251	T24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, TOTAL AREA 13650 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24501	19041-10000-22116	962 N MALTMAN AVE	90026	13	142-5A203 120	5427022003	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.08598	-118.27953	**Permit fee is zero per AB-1414/ SB-1222*[E-PLAN] PLAN CHECK ONLY. DELTA [A] CHANGES TO AN APPROVED SET. RELOCATING MSP, AC AND INVERTER TO THE NORTH-EAST WALL. PERMIT FEES PAID UNDER 19041-10000-18786	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24502	13041-10000-26131	617 W 7TH ST BASEMENT	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.04779	-118.2571	Core and shell upgrade for future TI design in a highrise office building.  7 new subpanels and 1 300 kVA XFMR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24503	15041-10000-37844	13420 W SATICOY ST	91605	2	186B157   183	2303024011	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.20861	-118.42526	T-24, PLAN CHECK FOR ENERGY ONLY FOR PARKING LOT LIGHTING. TOTAL SQ. FT. 49705.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24504	17041-20000-14475	812 W 165TH PL	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	33.88061	-118.28977	PV2. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTERS. SYSTEM SIZE: 50KW$0 permit fee is due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24505	19041-20000-45471	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Issued	11/12/2019 12:00:00 AM	ADDRESS	34.14441	-118.39252	TENTANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24506	19041-10000-29637	1132 N GLENDALE BLVD	90026	13	139-5A207 131	5404016022	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Issued	08/21/2019 12:00:00 AM	ADDRESS	34.07702	-118.26071	0$ final fees per AB1414NEW CARPORT MOUNTED PV2 SYSTEM WITH AN OVERALL SYSTEM SIZE OF 496KW PV SYSTEM WITH 1196 PV PANELS AND 7 CENTRAL INVERTERS AND A BATTERY SYSTEM ALL LOCATED AT 1132 N GLENDALE.  AS WELL AS A 60KWaC SYSTEM WITH ONE CENTRAL INVERTER AND 182 PV PANELS LOCATED AT 1100 N GLENDALE AVE NOTE AN EXPRESS PERMIT HAS BEEN PULLED FOR 1100 GLENDALE UNDER 20041-10000-17287	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24507	18041-10001-09538	12020 W BURBANK BLVD	91607	2	174B165   752	2348002042	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	ADDRESS	34.17198	-118.39447	VOID EXPEDITE PER APPLICANT REQUEST.............expedite per applicant requestPlan check for a commercial PV roof mounted system with 495KW AC, (9) combiner box, (9) 55kw inverter, (77) ckts and (1367) modules interconnecting through (2) subpanel and and (2) new 400kva transformer back feeding (2) services, 1800A and 1200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24508	14041-20000-21101	17955 W CALVERT ST	91335	5	177B129   191	2123033043	R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	PIN	34.18222494	-118.52473236	PV1.  Install 7.8 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24509	16041-20000-19777	4649 N MARY ELLEN AVE	91423	4	168B157   583	2360024019	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	10/15/2016 12:00:00 AM	ADDRESS	34.15543	-118.41938	PV1.  Install 8 kW roof mounted PV system.  (37) modules with (1) 5kW and (1) 3kW rated central inverters.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24510	15041-20000-26658	649 W 34TH ST Suite 101	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	PIN	34.02214675	-118.28186522	Plan check Title 24 only for USC. Total area: 680 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24511	14041-10005-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Issued	04/13/2016 12:00:00 AM	ADDRESS	34.0504	-118.26023	"Changes to permitted plans. Plans identify(clouded) each change on each sheet. CHANGES INCLUDE ADDITION OF RECEPTACLES, J-BOXES FOR TCP CONTROL PANELS;NEW CKTS AND A DISTRIBUTION BOARD TO SUPPLY  COMLACK REC IN THE BALLROOMS;REVISED LIGHTING  LAYOUT ON FEW FLOORS;REORIENTATED SWGR ESG((((((((((PLANCHECK FOR POWER AND ENERGY. HIGH RISE CORE AND SHELL BUILDING INCLUDING 5 LEVEL PARKING GARAGE. "" WILSHIRE GRAND "" PROJECT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24512	14041-20001-06374	7279 W CHETWOOD DR	91042	7	207B197   321	2553002021	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.26605	-118.29056	(((EXPEDITE FEES)))PV2 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24513	17041-20000-02304	10349 N BALBOA BLVD 207	91344	12	204B133    62	2695020024	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Issued	01/25/2017 12:00:00 AM	ADDRESS	34.25857	-118.50252	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 680.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24514	19041-10000-51750	7018 N VAN NUYS BLVD	91405	6	183B149   328	2217007051	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM			Ready to Issue	08/21/2020 12:00:00 AM	ADDRESS	34.19802	-118.44847	PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW CIRCUITS, LIGHTHING, AND CONTROLS. TOTAL AFFECTED AREA IS 2244 SQAURE FEET. PERMIT FEES UNDER 20041-90000-19706.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24515	16041-10001-30254	5840 S VAN NESS AVE	90047	8	105B189    31	6001004013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM			PC Approved	09/14/2016 12:00:00 AM	ADDRESS	33.98783	-118.3175	Addition of  a new roof mounted PV solar system to an exsiting system. The new system is rated at 2.5 kw (microinverter: M50-60-2LL). ** existing system is rated at 3.0 KW (IG 3.0) as provided by applicants. Permit was paid under application 16041-90000-18486	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24516	19041-10000-06332	2188 N MANDEVILLE CANYON ROAD	90049	11	138B133   495	4493003023	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.07625	-118.49931	*This is plan check only for the utility shed . Electrical permit is covered under combo Building Permit # 16010-10000-04870 ((B# 16010-10000-04870 - Main House,  B# 16010-10000-04871 - Rec. Room,  B# 16041-10000-04872 Utility & Storage structure))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24517	14041-20000-27709	18136 W LAKE ENCINO DR	91316	5	165B125   211	2184040025	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM			PC Approved	10/07/2014 12:00:00 AM	ADDRESS	34.1489	-118.52976	CHANGES TO APPROVED SET OF PLANS. CHECK INTERCONNECTION. LOAD SIDE CONNECTION. PERMIT ALREADY ISSUED UNDER APPLICATION 14041-20000-22553	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24518	19041-20000-21343	21150 W CALIFA ST	91367	3	174B105    17	2149002019	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.17695	-118.5923	Plan check for Title 24 only, convert existing closet/storage into ADA bath room new lighting and receptacle. Total area: 218 sq ft. B#16016-20001-18892	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24519	19041-20002-51429	1943 W ESTES ROAD	90041	14	163-5A223  39	5671005009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			Reviewed by Supervisor	01/02/2020 12:00:00 AM	ADDRESS	34.14385	-118.21089	PV1. INSTALL 11.16 KW DC PV SYSTEM WITH (191) TESLA TILE MODULES, (2) INVERTERS AND (2) ENERGY STORAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24520	18041-20000-45650	869 N LINDA FLORA DR	90049	5	141B145   217	4368023021	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.08222	-118.4651	800A 208Y/120V 3ph-4w service, distribution, power and lighting for new SFD.  Plan check for power.  Electrical permit fees paid under 18010-30000-00371.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24521	16041-20001-38670	642 N STANLEY AVE	90036	5	141B177   701	5526015023	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.08309	-118.35622	expedite per requestpv1install roof mounted pv system sized 7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24522	15041-10000-29401	3820 S CRENSHAW BLVD	90008	10	117B185   661	5033003017	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.01668	-118.33474	PC for energy only. TI on a liquor store, addition walking cooler. Total area: 1235 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24523	14041-20000-19001	7747 N LEMP AVE	91605	6	189B169   798	2316001018	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	09/01/2014 12:00:00 AM	ADDRESS	34.2116	-118.3846	PV1Install roof-mounted solar array on SFD. System size: 3.8kW.(1) SolarEdge SE3800-US transformerless inverter(17) SolarEdge P300 power optimizers(17) Solar World SunModule SW250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24524	16041-10002-34606	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM			PC Approved	03/08/2018 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISIONS TO SINGLE LINE ON SHEET E-505 :  LOADS AHUs AND EF-13 ARE TO BE SUPPLIED FROM NEW 600A DISTRIBUTION BOARD EDB10HC WHICH IS SUPPLIED FROM EXISTING EDB10HA. THIS CHANGE ENABLES OTHER LOADS TO BE SUPPLIED THROUGH EDB10HA FROM EDB10HC .PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24525	12041-20000-21298	4248 N LAURELGROVE AVE	91604	2	165B165   740	2367006009	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.14817	-118.4007	Enphase system on roof of a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24526	13041-10000-18163	9301 N TAMPA AVE # 193	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	INTERIOR REMODEL OF EXISTING TENANT SPACE, TITLE 24 AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24527	14041-10000-12479	5744 S BRYNHURST AVE	90043	8	108B185   821	5006003016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Issued	09/11/2014 12:00:00 AM	ADDRESS	33.98954	-118.33317	""" $0 permit fee is due to the 2012 Senate Bill No. 1222"" PV1 5.72KWdc. 240V. negative GND and ungrounded. NONstd. Battery System.  1story. Roofmount. [(8) inverters: {(1) OUTBACK flexpower one GVFX3648 negatively grounded (3.6kW) with Outback power IBR-3-48-175} and (7) ENPHASE ENERGY M215-60-2LL-S2X-IG Transformerless]. [(22 - 15 connected to outback and 7 microinverters)modules: {SunEdison F260}]     'Expedited plan check per applicant request'The solar PV installation shall comply with the Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96 or approved plans by the LAFD."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24528	18041-10000-41055	3019 N ANDRITA ST	90065	13	154-5A213 198	5458007009	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.11616	-118.24616	REMOVE INDOOR AND OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24529	16041-10002-23313	10250 W SANTA MONICA BLVD 202	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Info Complete	10/21/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set.  Changes to feeder schedule and addition of 7 new branch circuits.  Voltage drop calculations updated.  All changes clouded.        PC FOR POWER AND ENERGY. THE INTERIOR BUILDING OUT OF AN EXISTING SHELLED OUT TENANT SPACE INCLUDING EXTERIOR PATIO ON THE SAME FLOOR OF A SINGLE STORY BUILDING. TOTAL AREA (2160+ 465) SQ FT.B# 16016-10000-15382	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24530	12041-10000-17668	10223 S CENTRAL AVE	90002	8	090B209   521	6049026006	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	08/08/2012 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	33.94341	-118.25436	CHANGE OF USE FROM  OFFICE TO  FOOD MARKET/RETAIL AND NEW RESTROOM.  Load is 110 Amps total, retail.  Plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24531	12041-10000-04548	719 S BROADWAY	90014	14	127-5A209  53	5144014037	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.04483	-118.25393	T.I. on the existing Woolworth Building.  Interior upgrade of Basement and Ground levels for New retail space with loading dock and storefront modification.  New panels, circuits, loads, xfrmr, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24532	10041-10000-16453	2846 W 8TH ST #204	90005	1	132B197   495	5077022030	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.05758	-118.28811	T.I. to existing building.   Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24533	19041-10000-42370	20953 W OSBORNE ST	91304	3	195B109    47	2779001030	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Issued	11/15/2019 12:00:00 AM	ADDRESS	34.23315	-118.59033	0$ FINAL FEES AB1414PV2, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 26.4 KWdc/22.8KWac. SCOPE OF WORK INCLUDES 110 MODULES (ORION ECO240S15P-60) WITH OPTIMZERS (SE P320) AND THREE CENTRAL INVERTERS (SE7600H-US) LEADING TO A 200A LOAD CENTER. INTERCONNECTED TO A 800A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24534	12041-20000-31114	4518 N BECK AVE	91602	2	168B169  1026	2365008012	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.15273	-118.38323	Enphase system on roof of single family dwelling with solar load center panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24535	14041-10001-04153	12953 W MAGNOLIA BLVD	91423	4	171B161   511	2345017008	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			Reviewed by Supervisor	03/06/2014 12:00:00 AM	ADDRESS	34.16502	-118.4155	Expedited RSES plan check per applicant request.{{PV1, Install 8.25 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 6000A-US-ZB-U. (33) Modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24536	14041-20000-04851	10989 N BARTEE AVE	91345	7	210B149  1062	2615020018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.2695	-118.45244	Roof mounted PV system with 4KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24537	12041-10000-13569	5509 N STANSBURY AVE	91401	2	174B153  1017	2245026007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.17058	-118.44121	Plan check for PV system, SFD. 11.4kW DC on the rooftop.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24538	17041-20001-25677	9301 N WINNETKA AVE	91311	12	198B113   122	2748038032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.23934	-118.57134	05-07-2018 Changes to an approved set of plans, changes include addtion of  2 UPS(uninterruptible power supply) into existing panel. Changes has been clouded as delta 7.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24539	14041-20000-06921	9810 N ZELZAH AVE	91325	12	201B129   126	2755001019	(Q)R3-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.24898	-118.52309	pv2 commercial rooftop. interconnect to 3 different service points. system combined size 77.4kw ac. using mutilple inverters. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24540	12041-10000-09095	12776 W FOOTHILL BLVD	91340	7	216B161    44	2514007043	[Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	PIN	34.29079383	-118.41362215	Classified hazardous location, Existing Bus Repair Garage to be retro-fitted for CNG buses.  New equipment, wiring, and removal of lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24541	13041-10001-26418	4664 N DEL MORENO DR	91364	3	168B113   418	2174019014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM			Reviewed by Supervisor	10/10/2013 12:00:00 AM	ADDRESS	34.15491	-118.57526	][][]EXPEDITED PER APPLICANT REQUEST ][][PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH 400A LOAD BUS, (2) 200A PANELS AND EXISTING SOLAR INSTALLATION. ANTICIPATED INSTALLED SYSTEM SIZE IS 5.635 KW DC ( 23 X 245W) ON non-standard plan IN A 1-story  HOME. NEW load center IS UTILIZED.(23) MODULES: TRINASOLAR TSM-245PA05.18(1) INVERTER: POWER-ONE #AURORA PVI-50000OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24542	10041-10000-17597	1285 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.05069	-118.2254	Solar voltaic system installed on the roof of the building.  Consists of  8 modules,  8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24543	18041-10000-11856	12200 W OLYMPIC BLVD suite 170-175	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM			PC Info Complete	04/04/2018 12:00:00 AM	ADDRESS	34.03195	-118.45506	PC for power and energy for office TI. Installing new panel, lights, receptacles and equipment. Total new load<400A.  Total 3462sqft.18016-30000-04459B: Non-structural tenant improvement to office building 3,485 sf.  No use/ occupancy change. No exterior work	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24544	14041-10000-31538	14238 W COHASSET ST	91405	2	186B153   148	2215021005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.20652	-118.44365	Plan check for roof-mounted PV system. System size is 7.535 kW AC. System consists of (17) modules in 3 strings, and (2) inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24545	17041-10000-20219	18711 W DEVONSHIRE ST	91324	12	204B121    71	2728028023	C2-1VL, QC2-1VL, QP-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Issued	06/29/2017 12:00:00 AM	ADDRESS	34.25745	-118.54085	Title 24 plan check.  T.I. to existing restaurant.  New lighting and receptacles in FOH.  All subpanels to remain existing.  Toal area = 3,220 sq. ft.       Building permit #17014-10000-01769	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24546	13041-10000-34370	18050 W OSBORNE ST	91325	12	195B125   194	2768005010	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Expired	01/19/2016 12:00:00 AM	ADDRESS	34.23346	-118.52661	PV1, install 7.5 kw DC roof-mounted solar array for a 1-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE6000A-US. (30) modules: Renesola JC250M-24Bb.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24547	19041-20000-39220	9413 N VANALDEN AVE	91324	12	198B121   204	2762019002	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.24123	-118.54933	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZEI IS 9.36 KW DC/10 KW AC. SCOPE OF WORK CONSISTS OF (26) PV MODULES WITH OPTIMIZERS AND A 10KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24548	18041-10002-49025	400 W WORLD WAY T4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM			PC Approved	11/06/2019 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK ONLY FOR LOST SET OF APPROVED PLANS, ALL PERMIT FEES ARE UNDER THE MASTER APPLICATION UNDER 18041-10000-49025Energy plan check for a COMMERCIAL TENANT IMPROVEMENTS. Scope includes new lighting and equipment with a total area of 5926-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24549	19041-20000-26298	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	03/09/2021 12:00:00 AM		Permit Finaled	09/19/2021 12:00:00 AM	ADDRESS	34.10191	-118.28217	1600A 4160-208/120V SUBSTATION REPLACEMENT FOR EXISTING COMMERCIAL  MOVIE STUDIO LOT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24550	16041-20000-34979	1655-1665 N RODNEY DR	90027	4	147B197   246	5542001017	RD1.5-1XL	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Issued	10/04/2016 12:00:00 AM	ADDRESS	34.10138	-118.28983	Plan check for power only. New 600A service, house panel, and unit panels for 12 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24551	19041-20000-37752	18434 W BRYANT ST BLDG A	91325	12	195B125   976	2786005011	P-1VL, [Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	01/08/2021 12:00:00 AM		Permit Finaled	05/05/2022 12:00:00 AM	ADDRESS	34.22725	-118.53502	NEW  MINOR AUTOMOTIVE REPAIR SHOP HAZARDOUS LOCATION WITH 400 AMP SERVICE 120/240 V 3 PHASE. PROVIDE PANELS, EQUIPMENTS, AND LIGHTS.BUILDING A. BUILDING# 19010-20000-04092	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24552	15041-10000-43649	159 E 82ND PL	90003	9	099B205  1235	6030007019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	33.96465	-118.27186	PV1, ROOF MOUNTED SOLAR SYSTEM WITH A CENTRAL INVERTER. (7) MODULES AND (1) INVERTER -3.0 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24553	16041-30000-44991	123 N LARCHMONT BLVD	90004	4	138B189   883	5515019016	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.07377	-118.32382	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 915 sq. ft.Note: Building application has been generated under 16016-10000-30324	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24554	12041-20000-06938	14113 W ROSCOE BLVD	91402	6	192B153   753	2638030026	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.22183	-118.44069	New Fire Alarm system for school in  trailers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24555	12041-10000-30438	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	EXISTING COMMERCIAL BUILDING COMPRISED OF TWO FLOORS AND A BASEMENT.  THE BUILDING HAS SUFFERED MAJOR FIRE DAMAGE.  THE FIRST AND SECOND FLOORS WILL BE COMPLETELY DEMOED AND THE BASEMENT WILL BE LEFT WITH BARE WALLS.  TWO NEW FLOORS WILL BE CONSTRUCTED OVER THE BASEMENT AND THRE T.I'S WILL TAKE PLACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24556	13041-10000-00756	17351 W SUNSET BLVD	90272	11	126B117   567	4416003034	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	Commercial			01/11/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.04039	-118.5542	"PLAN CHECK POWER AND ENERGY. TI OF 1ST FLOOR FOR NEW TENANT SPACE. OFFICE SPACE, GYM, AND FLORIST SHOP.  ""COMPLY WITHDEPARTMENT ORDER effective date 08/22/2008. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24557	13041-20000-35087	6222 N KESTER AVE 1-22	91411	6	178-5A149 166	2241016012	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.18315	-118.4573	PC FOR POWER AND ENERGY. ENERGY FOR PARKING. LOW RISE RESIDENTIAL. NEW 22 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24558	16041-20000-36316	715 S MORENO AVE	90049	11	126B141   228	4264007051	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Issued	10/31/2016 12:00:00 AM	ADDRESS	34.04297	-118.484	pv1install roof mounte pv system sized 14kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24559	12041-10003-05678	1355 S FLOWER ST	90015	9	126A205   115	5134010019	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			01/16/2014 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	34.03876	-118.268	changes to approved set of plans: removed main  FP2. downsized breaker for MS2A to 800A. fire pump conductors in concrete. Downsized conductors and relabeled exhaust fans and motors for garage.NEW 7-STORY, 80 DWELLING UNITS (76 APARTMENTS AND 4 LIFE/WORK UNITS) COMPLEX WITH SUBTERRANEAN PARKING.PLAN CHECK POWER AND ENERGY. IN METHANE ZONE.VARIANCE TO SEPARATE THE FA PLANS WAS OBTAINED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24560	13041-20001-29089	23030 W BURTON ST	91304	12	189B097    52	2014038014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.21813	-118.62933	(((EXPEDITE FEES ONLY)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE8.25 KW. 3 STRINGS 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24561	13041-10001-35682	14738 W BLACKHAWK ST	91345	7	204B149   186	2648010007	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	ADDRESS	34.25803	-118.45366	Expedited RSES plan check per applicant request. {{PV1, Install 4.5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (18) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24562	15041-10000-00696	541 S SPRING ST	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.04657	-118.2507	Energy plan check for a restaurant TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24563	14041-10000-34730	8556 S EMERSON AVE UNIT 8	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	01/30/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 8 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24564	15041-10000-28790	516 W 62ND ST	90044	9	105B201   904	6004022004	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	33.98317	-118.28329	PV1. NEW ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE IS 3.00 KW.(12) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-ABB# PVI-3.0-OUTD-S--US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24565	12041-10000-18793	101 E MANCHESTER AVE	90003	9	097-5A205 337	6030017024	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Info Complete	08/09/2012 12:00:00 AM	ADDRESS	33.96026	-118.27364	"TI IN AN EXISTING ""EL POLLO LOCO"". PLAN CHECK FOR T-24 ENERGY CALCS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24566	14041-10000-05146	1496 S STEARNS DR	90035	10	129B173   800	5068013025	R1-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.04942	-118.37173	PV1, INSTALL 4,5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.MICRO INVERTER M215-60-2LL-522(21) MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24567	16041-30000-45020	922 W 2ND ST	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Info Complete	12/22/2016 12:00:00 AM	ADDRESS	34.0568	-118.2539	Plan check for the replacement of a FACP for an existing fire alarm system. Project site is an existing 3-story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24568	15041-20000-01181	19301 W LAVY CT	91356	3	174B117   671	2153034057	(T)R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2015 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.17662	-118.55372	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING TOTAL OF 15 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24569	17041-20001-15671	4507 N ATOLL AVE	91423	4	165B157    64	2360027021	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.15241	-118.42053	05/01/2018 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the interconnection configuration to match the field installation.*****Previous Work Description*****Plan check for AC coupled battery backup system. (2) 5kW Tesla Powerwall 2.0. Connected to subpanel feeding existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24570	12041-10000-13986	11614 W PICO BLVD	90064	11	123B153   669	4260033021	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM			Corrections Issued	08/07/2012 12:00:00 AM	ADDRESS	34.03217	-118.44413	T.I. to an existing Salon.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24571	14041-10001-28671	4920 S AVALON BLVD	90011	9	111A207   203	5108011029	PF-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	33.99807	-118.26503	((10/23/2014 - Supp. app. for title 24 plan check only at request of inspector))T.I. WORK - REPLACE LIGHTS & OUTLETS. INSTALL DATA LINES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24572	11041-10000-03028	12006 W VENICE BLVD	90066	11	114B157  1283	4235024900	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			02/16/2011 12:00:00 AM	02/16/2011 12:00:00 AM		Issued	02/16/2011 12:00:00 AM	ADDRESS	34.00591	-118.42897	NEW FIRE PANEL, AND 72 DEVICES IN EXISTING LIBRARY BUILDING.  OVER THE COUNTER PLAN CHECK.  SINGLE STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24573	16041-10000-26791	18840 W VENTURA BLVD #110	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.17186	-118.54425	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTING URGENT CARE CENTER (MEDICAL TI). SCOPE INCLUDES 3 NEW PANELS, LIGHTS, RECEPTACLES, AND ONE NEW X-RAY . TOTAL AFFECTED AREA IS 2581 SQ. FT. B#16016-20000-17424	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24574	11041-20000-22588	10154 N FERNGLEN AVE bldg.1	91042	2	204A197   327	2558023022	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			10/21/2011 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.25396	-118.29421	NEW 5 UNIT APT W/ATT GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24575	18041-10001-46878	225 N VERMONT AVE 139A	90004	13	138B197   512	5518033032	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2112.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	08/04/2020 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	34.07529	-118.29188	CHANGES TO AN APPROVED SET OF PLANS. SCOPE OF WORK INCLUDES THE REVISIOIN FROM 200 AMP TO 400 AMP PANEL NOTED UNDER DELTA 3 ONLY. PC ONLY__________________PC FOR TENANT IMPROVEMENT TO FIRST TIME TENANT( SALON) RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24576	16041-20003-04342	16300 W SHADOW MOUNTAIN DR	90272	11	132B121   218	4420039003	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.05841	-118.5395	$0 plan check fee per State Senate Bill SB 1222.  System design revisions.  From (34) panels to (31) panels.  Removal of combiner box and reduction of strings to (2) from (3).  (((Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (34) modules, (1) inverter, and (1) combiner box. System is being interconnected with a 600-amp main service panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24577	10041-20000-22277	920 BLOOM WALK	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	11/14/2011 12:00:00 AM		Issued	11/14/2011 12:00:00 AM	PIN	34.02030756	-118.28890608	Install new swtichboards, generator, ATS, and transformers rated over 600 volts for USC building.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24578	13041-10001-36159	2840 W SAN FERNANDO ROAD	90065	1	150B213    59	5457003018	[Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.11065	-118.24419	Expedited RSES plan check per applicant request.{{PV2, Install roof mounted solar array system for an office with two building under one address. Interconnect with existing service 400 amp.(15)Transformered Inverters :Power One PVI-10.01-208V. (660) modules: REC PEAK ENERGY REC 250PE.ROOF #1: 28 strings with 308 modules, ROOF #2: 32 strings with 352 modules }}Plan checker please check if the owners are the same.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24579	13041-10009-07125	770 S GRAND AVE	90017	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Issued	10/25/2016 12:00:00 AM	ADDRESS	34.04603	-118.25748	PC FOR EXTENSION OF SCOPE OF WORK. ADDITION OF DISTRIBUTION AND TRANSFORMERS FOR CORE AND SHELL OF FUTURE RESTAURANTS. changes noted delta 25 on plans	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24580	18041-10000-20725	5260 W 104TH ST	90045	11	090B173   292	4129035012	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	33.94183	-118.37221	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24581	14041-10000-16866	8090 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	33.95166	-118.43325	CHANGED ENGINEER OF RECORD FROM DON WARREN e8513 TO BEN MASCARDO e8130. REFERENCE 13041 10000 11306. CHANGES ON PLAN INCLUDE service load calc by kva rating of xfrmr, 3/0 EGC. plan check for power only. TEMPORARY CONSTRUCTION SITE. INSTALLATION OF TEMPORARY TRAILERS. SCOPE OF WORK CONNECTING PANELS TRLD, TRLE, TRL1, 2, 3, 4 to SWBD DSTA as indicated by single cloud.  PROJECT LOCATED IN A METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24582	15041-20000-20567	7332 N KELVIN AVE	91306	3	186B109  1058	2113014062	(Q)RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.20389	-118.58614	Plan check for PV roof mounted sytem. System size: 4.5kW with 20 modules and 1 inverter (4.2kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24583	13041-20000-18333	5724 W GREEN OAK DR	90068	4	154-5A191 156	5580021026	RE15-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.11841	-118.31456	pv1 single family dwelling. total system size 5.8 kw. using transofrmerless inverter. 26 modules. nonstandard plan. internal string combiner	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24584	16041-10000-16332	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	33.76597	-118.28407	PV2 5.1 Mega watts roof-mounted system with 23,184 modules, and 64 inverters interconnecting through utility transformers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24585	15041-10000-15682	12180 W MILLENNIUM 5th Flr	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	Full plan check for first time tenant, office located at the 5th floor of a commercial building. Scope include new equipment, lighting and receptacles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24586	18041-20000-26457	8554 N BURNET AVE #110	91343	6	192B145   725	2654023***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.22606	-118.46317	PV1.  Install 5.4 kW DC roof mounted grid tied PV system.  (18) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24587	16041-10000-11849	10215 N TUJUNGA CANYON BLVD	91042	7	204B197  1137	2568009021	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.25171	-118.29116	PC FOR POWER.NEW 2-STORY 8 UNIT APT BLDG W/ON GRADE PKG . BUILDING A. THIS BUILDING IS PART OF A TWO BUILDING APARTMENT BUILDING, BUILDING B WITH  APP # 16041-10000-11833 INCLUDES T24 FOR BOTH BUILDING.BOTH PLAN HAVE THE SAME  PCAM# E16LA01339.B# 13010-20000-02108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24588	13041-10000-29621	1 WORLD WAY terminal 4-T31	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	33.94469	-118.39817	"TITLE,24 PART 6 LIGHTING TO INSTALL ILLUMINATED BLADE SIGN 1'8'W' X 4'10W FOR LAX TERMINAL 4, FOODCOURT. SIGN READS""800 neapolitan pizzeria degrees"" . total sign area = 8.33 sq ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24589	10041-20003-24663	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	ADDRESS	34.05373	-118.26606	PLAN CHECK FOR LOST SET OF PLANS. RECHECK THIS ENTIRE SET AS NEW. PER BUILDING PC IN ACCORDANCE TO 2008 ENERGY CODE. PERMIT WILL BE ISSUED FOR DIFFERENCE IN INSPECTION ITEMS FROM ORIGINAL APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24590	14041-10000-11656	2430 W LOY LANE	90041	14	162A221   166	5683024010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.13825	-118.22019	PV 1 - Install roof-mounted solar array, interconnect with main panel.system size = 3 kW ac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24591	17041-10000-17936	15250 W VENTURA BLVD #1220-1215	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.15351	-118.46549	Plan check for Title 24.  T.I. to office space in existing commercial highrise building.  New lighting and receptacles.  Total area = 1,088 sq. ft.       Building permit #17016-10000-14101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24592	18041-10000-41091	3785 W WILSHIRE BLVD #102CD	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.06187	-118.30858	TENANT IMPROVEMENT OF EXISTING OFFICE. T-24 ENERGY ONLY. 1,760 SQR FT.BULDING PERMIT: 18016-10000-33214	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24593	14041-20000-04284	22727 W MICHALE ST	91304	12	195B097     4	2004015020	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.22692	-118.62233	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (N) 200A SERVICE PNL. MICROINVERTER SYSTEM, SIZED @ 1.94 kW AC, WITH (4) KYOCERA KD240GX-LFB, (5) GRAPE SOLAR GS-S-250-FAB5 MODULES , (9) ENPHASE M215 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24594	13041-10000-27148	7270 W MANCHESTER AVE	90045	11	096B157   625	4119026044	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	33.95959	-118.42143	NEW FIRE ALARM SYSTEM. 6 STORY BUILDING. 2 PANELS AND 843 DEVICES. APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24595	13041-20000-05119	6920 N VAN NUYS BLVD	91405	6	183B149   499	2217009801	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.19604	-118.44846	Extend existing electrical distribution system.  (Add additional gear for redundancy and some new loads, and lighting.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24596	13041-10001-34487	6250 N TOPANGA CANYON BLVD BLD # F	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	06/22/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Changes to an approved set of plans. Changes include relocating load circuits. No new circuits or panels added. All changes are clouded. Approved for submittal per F.Y.*****Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING F.BUILDING PERMIT # 13010-10000-02909.New  retail  bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24597	18041-30000-00815	633 W 5TH ST #825	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 in existing high-rise building. Totla area: 1610 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24598	13041-20000-03685	13725 W BAYLISS ROAD	90049	11	138B133    35	4492015018	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.0781	-118.50787	Photovoltaic system on roof of single family dwelling using Enphase inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24599	15041-10000-02580	380 W WORLD WAY T86	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check for Title 24 Sign Lighting only. Permit is for (2) branch circuits for indoor sign lighting (sign is within Tom Bradley Terminal; sign is not visible from right-of-way).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24600	14041-20001-35565	17809 W SIDWELL ST	91344	12	219B129   653	2601071005	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.30054	-118.5224	PV1. Install roof mounted PV system sized 10 KW. Interconnected with main service pannel.(44) Sunmodule SW250(1) Solar Edge SE10,000A Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24601	13041-20000-12528	701 W EXPOSITION BLVD B3	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/16/2013 12:00:00 AM	ADDRESS	34.01842	-118.2857	T24 FOR EXISITING LECTURE HALL FOR USC. 3704 SQRFT. SCOPE OF WORK IN LECTURE HALL B3. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24602	13041-10000-07878	12060 N BEAUFAIT AVE	91326	12	216B125    17	2870004025	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.29231	-118.53745	PV1 - PLAN CHECK FOR 13.475 ROOF MOUNTED PHOTOVOLTAIC SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24603	15041-20002-17696	18711 W SHERMAN WAY	91335	3	183B121   100	2118026019	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.20128	-118.54074	changes to an approved set of plans.  reduce AIC rating from 100K to 65K AIC.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24604	19041-20000-36592	22140 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	06/03/2022 12:00:00 AM	ADDRESS	34.18618	-118.6099	PV2.  Plan check for PV roof mounted system, system size: 30.015KW DC, 26.7KW AC CEC with 69 PV Modules and 2 inverters(14.4KW)Note: 12 Buildings in 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24605	14041-20000-25119	12658 W SANDHILL LANE UNIT 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.97735	-118.41444	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.38 KW INTERCONNECTED WITH MSP FOR UNIT 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24606	17041-30000-06410	445 S FIGUEROA ST Suite 3600	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for Title 24 only. Project site is a portion of the 36th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,325 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24607	16041-30000-24355	20743 W CLARK ST	91367	3	174B109   683	2151031052	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.1689	-118.58423	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition size is 3 kWac for a total system size of 6 kWac. Addition consists of (1) inverter, (15) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24608	13041-20002-17228	9223 N DEERING AVE	91311	12	198B105   114	2746010048	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			PC Approved	06/03/2015 12:00:00 AM	ADDRESS	34.23859	-118.59622	06/03/2015 Changes to an approved set of plans. Project scope is the addition of 84 ft of cable tray, (1) 225-amp panel, and associated loads.Note: Permit fees have been paid under the master application.*****Previous Work Description*****Changes from previously approved plans.  Removed one 150KVA transformer and  removed 45KVA transformer.  Plan check for power only.Note: Permit is under the original approval.*****New circuits and equipment for an existing low-rise commercial space.  Networking/Server equipment.  Plan check for Power, no change to lighting.  Project valuation is less than $200,000 per applicant - No green fee charged.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24609	16041-20001-36135	17551 W MARGATE ST	91316	5	171B129    54	2257003041	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM			PC Approved	10/15/2016 12:00:00 AM	ADDRESS	34.16774	-118.5159	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20.140 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24610	13041-10001-01935	9845 N WORNOM AVE	91040	7	201B181   164	2543032003	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.24863	-118.35209	MODIFICATIONS TO APPROVED SET OF PLANS. NUMBER OF CONDUCTORS IN CONDUIT TO SUBPANEL UPDATED FROM 20 TO 15, DISCONNECT UPDATED TO FUSIBLE DISCONNECT. **************************************************13041-10000-01935 DESCRIPTION: photovoltaic system for single family dwelling. USING TOTAL OF 74 SOLAR MODULES. USING ENPHASE M215. SOLAR PANEL SUNMODULE SW240. TOTAL SYSTEM SIZE OF 15.98 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24611	14041-20000-12627	445 S FIGUEROA ST 31st Floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	T.I. to existing high rise building on the entire 31st floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24612	19041-20000-03939	519 S GAFFEY ST	90731	15	015B197   184	7451030034	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	33.73932	-118.2925	Plan check for Title 24 only change of use from retail to barbershop in existing space Tenat Improvement. Total area: 1069 sq ft. B#19016-40000-02314Ok to issue per management.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24613	18041-10000-40458	13700 W SHERMAN WAY	91405	2	183B157   986	2216027022	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	08/14/2019 12:00:00 AM		Issued	08/14/2019 12:00:00 AM	ADDRESS	34.20093	-118.43163	TI IN AN EXISTING MADONALD RESTAURANT. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-33004	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24614	17041-20000-43164	1400 N MARTEL AVE 1-33	90046	4	147B181   939	5550019072	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.09611	-118.35052	PV2.  Install roof mounted PV system sized 25 kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24615	12041-20001-21517	9601 N BARTEE AVE	91331	6	201B157   779	2621026010	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2012 12:00:00 AM			PC Approved	11/21/2012 12:00:00 AM	ADDRESS	34.24425	-118.42573	PV1 SOLAR INSTALLATION ROOF MOUNTED. SYSTEM SIZE IS 7.5KW.  STANDARD PLAN.PLAN CHECK ONLY. PERMIT WAS PULLED UNDER APPLICATION NUMBER: 12041-20000-21517.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24616	13041-20000-00169	22325 W NAPA ST	91304	12	192B101   155	2004018022	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.22507	-118.61412	New 5.52KW rooftop mounted PV system for an existing single family residence.   System is ungrounded/transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24617	13041-10000-31751	101-109 S LA BREA AVE BUILDING A-LEVEL 1	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.07338	-118.34425	METHANE GAS CONTROL SYSTEM; CHANGE OF SYSTEM FROM SIERRA GAS DETECTION TO INTEC GAS DETECTION SYSTEM.  TENANT IMPROVEMENT TO AN EXIASTING COMMERCIAL BUILDING. METHANE ZONE DESIGN LEVEL 5EXISTING ELECTRICAL PERMIT UNDER: 13041-10000-14984 FOR SIERRA GAS DETECTION SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24618	10041-20000-14546	1025 W 190TH ST	90248	15	060B197   535	7351029020	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	33.85848	-118.29375	Plan check T-24 Energy (general/emergency) lighting for bank TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24619	19041-20000-52245	4171 N EMPRESS AVE	91436	5	165B133   408	2292004002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Issued	12/18/2019 12:00:00 AM	ADDRESS	34.14708	-118.50193	PV1. INSTALL 7.56 KW DC PV SYSTEM WITH (24) MODULES, OPTIMIZERS, (1) INVERTER(SE7600) AND (3) TESLA ENERGY STORAGE SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24620	14041-20003-13786	20630 W NORDHOFF ST	91311	3	195B109    49	2780001039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Approved	09/03/2014 12:00:00 AM	ADDRESS	34.23282	-118.58205	CHANGES TO APPROVED SET OF PLANS. CHANGE IN CIRCUIT DESIGNATIONS. NO OTHER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24621	16041-10000-06885	3761 S WEST BLVD	90008	10	117B181   258	5045003001	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Refund in Progress	06/22/2016 12:00:00 AM	PIN	34.01807931	-118.34154063	PV1 , INSTALL 3.18 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(12) MODULES: CANADIAN SOLAR(1) INVERTER: GINLONG SOLIS-4K-2G-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24622	15041-10000-12267	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	PC FOR ENERGY. TI FOR OFFICE TER 3 OF LAX. TOTAL AREA 635 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24623	17041-10000-33159	11176 W PENROSE ST	91352	6	192B173    29	2408022029	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Issued	09/15/2017 12:00:00 AM	ADDRESS	34.22684	-118.37435	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 16900 SQ.FT (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24624	19041-20001-20075	2222 E WASHINGTON BLVD	90021	14	118-5A217 138	5167005027	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.0188	-118.23256	Revision to approved set of plans.  Revisions made to HVAC system, adjustment of load calculations and panel schedule details.  Approval of clouded revisions only.(((FULL PLAN CHECK FOR CHANGE OF USE FROM WAREHOUSE TO INDUSTRIAL HYDROPONICS. SCOPE OF WORK INCLUDES A NEW 100A PANEL,T24 INCLUDED. TOTAL SQUARE FOOTAGE = 3034 SFB#18016-10000-40841)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24625	18041-20000-07668	1800 E PACIFIC COAST HWY	90744	15	036B213   462	7428001041	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.7911	-118.24041	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24626	13041-20000-32553	3633 S MENTONE AVE	90034	5	120B161   960	4314009038	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			11/20/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.02349	-118.40796	PLAN CHECK FOR EXIT SIGN INSTALLATION ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24627	14041-20001-24835	7006 S HOOVER ST UNIT 2	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #2.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24628	19041-20000-41051	11881 W TERRA VISTA WAY #105	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24629	14041-10000-03114	1611 S STANLEY AVE	90019	10	129B177  1426	5069013003	R1-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.04631	-118.36283	PV1.  Install 5.865 kW DC rooftop-mounted PV system, interconnect with main service panel.  Microinverter standard plan.  Enphase M215-60-2LL.  23 modules: Renesola JC255M-24/Bb	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24630	14041-20000-13932	8711 N CORBIN AVE	91324	12	195B117   211	2782022019	C2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.22864	-118.56246	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. YOUGURT AND JUICE BAR. NEWLY CONNECTED LOAD < 400 AMPS. 1378 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24631	19041-10000-08296	6611 S LA CIENEGA WESTWAY	90056	11	102B173   830	4102002042	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM			PC Info Complete	03/07/2019 12:00:00 AM	ADDRESS	33.97962	-118.3711	Energy plan check for a bank T.I, Scope includes new lighting and equipment with a total area of 1096-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24632	16041-10000-15180	5363 N BALBOA BLVD SUITE B	91316	5	171B133    38	2258027016	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM			PC Info Complete	04/29/2016 12:00:00 AM	ADDRESS	34.16893	-118.50129	TI TO EXISTING BUILDING. INSTALLING NEW LIGHTING AND EMERGENCY LIGHTING. INSTALLING NEW CONTROLLED RECEPTACLES. NEW CONNECTED LOAD LESS THAN 200 A. PLAN CHECK FOR TITLE 24 ONLY. TOTAL AREA OF 1097 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24633	13041-10000-19275	4700 W AMBROSE AVE	90027	4	150B197   227	5589022001	R3-1XL	Central	Hollywood	Greater Griffith Park		1892.02	Electrical	Electrical	Apartment			07/22/2013 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.10981	-118.29195	PLAN CHECK FOR A SERVICE UPGRADE FROM AN EXISTING 400A TO A NEW 600A SERVICE. LOCATION IS AN EXISTING 12 UNIT APARTMENT BUILDING. ALL UNIT PANELS ARE EXISTING, HOUSE PANEL IS EXISTING AS WELL. NEW MAIN BREAKER FOR ALL PANELS. IS IN SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24634	16041-20002-19799	12950 W PIERCE ST	91331	7	207B161   165	2536016014	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.26561	-118.41533	((9/15/2016))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 3 ON THE PLANS.  CHANGES INCLUDE ADDITIONAL EQUIPMENT TRANSFORMERS AND PANELS.(PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR VIDEO EQUIPMENT RENTAL.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24635	19041-10000-27950	436 S COLYTON ST	90013	14	127-5A215 333	5163022012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.04236	-118.23616	T-24 PLAN CHECK FOR A TI IN A WAREHOUSE. SCOPE INCLUDES NEW 400A SERVICE, EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA 7891 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24636	12041-10000-14793	220 E 2ND ST 1-104	90012	9	130-5A213 203	5161024014	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			06/26/2012 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.04978	-118.2429	PROPOSED MIXED USE PROJECT: 104 UNIT APARTMENTON FLOORS 2 TO 6 (TYPE IIIA), RETAIL AND OFFICE  ON THE 1ST FLOOR (TYPE I), PARKING ON 2 BASEMENT LEVELS AND 1ST FLOOR (TYPE I). SPRINKLERS USED FOR A STORY INCREASEneeds to file modivication to separate the fa plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24637	18041-20000-12148	10580 W STALLION RANCH ROAD	91040	7	204B177   253	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Issued	04/11/2018 12:00:00 AM	ADDRESS	34.25709	-118.36008	permit fee $0.00 by state senate bill no.1222pv1install roof mountrd pv system sized 18.4kw AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24638	19041-10000-16237	6144 N WHITSETT AVE 1-16	91606	2	177B165   366	2333010017	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Closed	11/15/2022 12:00:00 AM	ADDRESS	34.18245	-118.40507	FULL PLAN CHECK FOR 16 UNIT 4 STORY APARTMENT WITH SERVICE SIZE 1000AMP, 120/208V, 3 PH. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING. TOTAL EFFECTED AREA 19350 SQFT. Note: fire alarm variance has been paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24639	11041-10000-16164	5328 S CENTRAL AVE	90011	9	108B209   495	5104014037	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	33.99405	-118.25628	REMODEL OF CHILD CARE CENTERPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24640	13041-10000-29547	1933 S BUNDY DR bldg # 3	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.0344	-118.45642	Installation of a new fire alarm system and to provide 24-hour system monitoring to sprinkler system.  One-story commercial shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24641	19041-10000-29197	5821 S FIGUEROA ST	90003	9	108B201  1403	6004035029	C2-1VL	South Los Angeles	South Los Angeles	Voices		2371.02	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	33.98899	-118.28294	T-24, PLAN CHECK FOR LIGHTING ONLY. TI  - CHANGE OF USE FROM RETAIL TO  RESTAURANT.SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1424	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24642	15041-20000-38550	14055 W ARCHWOOD ST	91405	2	180B153   136	2238006032	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			11/16/2015 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.19309287	-118.439594	New 36 units Apartment with one retail next to the garage on the 1st floor. Retail area 379sq.ft.13 Typical units, MS 1200. Total area 20,660 sq/ft((((APARTMENT HOUSE WITH  FIRST FLOOR GARAGE AND REATIL SALES. ))))Modification for separate fire alarm from plans was submitted under different address 1556 Gordon with the same plan check number 15041-20000-38550 modification for  1556 gordon submitted on 12-8-15	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24643	12041-10001-11464	17423 W TUSCAN DR PV1	91344	12	222B129    26	2601020033	RE11-1-H-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2012 12:00:00 AM			PC Approved	07/30/2012 12:00:00 AM	ADDRESS	34.30632	-118.5128	Plan check to INSTALL SOLAR PANELS. (4.578KW) Solar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.  Permit for 14 modules and 1 inverter are on the main application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24644	16041-10000-08796	5749 N KLUMP AVE	91601	2	174B173   400	2337033017	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Expired	04/17/2018 12:00:00 AM	ADDRESS	34.17542	-118.37546	PV1, rooftop solar installation 2.4 kW     (11) SE-F270     (11) Enphase M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24645	15041-20000-09633	6828 N VAN NUYS BLVD	91405	6	183B149   704	2217009016	(Q)RAS4-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Closed	09/03/2015 12:00:00 AM	ADDRESS	34.19475	-118.44846	PLANCHECK FOR POWER AND ENERGY.  T. I. & CHG OF USE FROM RETAIL SPACES TO CLASSROOMS FOR CHAMPS CHARTER HIGH SCHOOL. 4798 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24646	16041-20000-41279	5005 N RUBIO AVE	91436	5	171B137   431	2259013003	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.16142	-118.49468	PV1.  Install 4.28 kW roof mounted grid-tied PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24647	12041-10000-03820	6022 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	33.94182	-118.39269	Relocation of a 800 Amp panel & a X-former. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24648	19041-20000-38890	18425 W NORDHOFF ST A	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM			PC Info Complete	09/27/2019 12:00:00 AM	ADDRESS	34.23566	-118.53473	Plan check for Title 24 energy only in existig space Tenant Improvement, Total 5200 sq ft. B#19016-20000-29220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24649	19041-10000-33011	888 S FIGUEROA ST # 700	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.0465	-118.26225	TENANT IMPROVEMENT IN OFFICES-NEW PANEL BOARD AND CKTS AND LIGHTINGPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24650	17041-10000-12195	12736 W EMELITA ST	91607	2	174B161   105	2341011009	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.17654	-118.4108	PC for Rooftop solar for 39 modules with 39 power optimerz(Solaredge) and 10KW centralized inverter.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24651	16041-10000-36122	10124 N BALBOA BLVD	91344	12	204B133   374	2685002902	C2-1VL, PF-1L	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.25464	-118.50216	T-24, PC FOR ENERGY ONLY. REPLACING LIGHTING FIXTURES FOR OUTDOOR. TOTAL AFFECTED AREA IS 111175 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24652	18041-20000-20119	620 N SIENA WAY	90077	5	141B149   172	4362002003	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.0822	-118.44643	Plan check for new generator install at SFD and 600A panel. Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24653	14041-10002-13157	12125 W VENICE BLVD	90066	11	114B157  1334	4248030035	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.0054	-118.43084	REVISIONS TO PERMITTED SET OF PLANS DURING CONSTRUCTION :added new ckts to panels D2; K;  A; ADDED 3 EA NEW DIMMER PANELS;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24654	15041-20000-32291	13443 N PALA AVE	91342	7	225B141   127	2603015097	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.31556	-118.47686	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (17) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24655	14041-20000-19183	9313 N DEBRA AVE	91343	12	198B137   491	2676005017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.23969	-118.49063	PV1Install roof-mounted solar array. System size: 6kW.(1) SolarEdge SE6000-US-ZB-U transformerless inverter(24) SolarEdge P300 power optimizers(24) Trina Solar TSM-255 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24656	11041-10002-07792	401 E CENTER WAY	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2780.00	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	PIN	33.93790872	-118.42837934	REVISION TO PERMITTED SET OF PLANS; 5KA BUS DUCT REPLACED WITH A CORNER SECTION  AND A 1600A SECTION WAS ADDED;  SOME LOADS WERE ALSO REMOVED  AND REFED FROM OTHER POWER SOURCES due to DWP'S DELAY, CONSTRUCTION TRAILERS ARE TO BE TEMPORARILY SUPPLIED FROM 500kw GENSET AND FFEDERS REPLACED WITH TYPE W CABLES IN ACCORDANCE WITH ARTICLE 400OF THE NEC.(((((((((((((((TEMPORARY POWER AT LAX FOR CONSTRUCTION TRAILERS. 5000A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24657	16041-30000-10039	135 N LARCHMONT BLVD	90004	4	138B189   832	5515019021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.07404	-118.32383	Title 24 plan check only.  Total area = 692 sq. ft.    T.I. to existing restaraunt space.  Two new subpanels (load < 150 A).  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24658	11041-10000-04954	525 S FLOWER ST B Level	90071	9	130-5A209 146	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.05109	-118.25696	T.I.  NEW OFFICE SPACES FOR THE BASEMENT LEVEL OF BUILDING.  USED TO BE A RETAIL SPACE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24659	11041-10000-18257	16500 W VENTURA BLVD	91436	5	168B137   382	2284005036	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	10/12/2011 12:00:00 AM	ADDRESS	34.15743	-118.49262	TI TO AN EXISTING BANK.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24660	14041-10000-13394	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	Title 24 for a starage space in existing commercial spaceTotal area = 239 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24661	10041-10002-25286	4666 W SANTA MONICA BLVD	90029	13	144B197   761	5539003024	C2-1D	Central	Hollywood	East Hollywood	YES	1914.10	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	04/24/2012 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	34.09066	-118.29149	New convenience store for a gas station. EPC is for power and Energy.  (( changes made to previosly approved set. addition of  pole lights.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24662	17041-10000-14224	5955 N DE SOTO AVE	91367	3	177B105    78	2149002027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.17888	-118.59071	PC for TI. Title 24 energy only. Installing new lights and receptacles.Total affected area 6747 sq.ft.installing new panels and circuits. BL # 17016-20000-07110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24663	15041-20002-39016	6510 W HOLLYWOOD BLVD	90028	13	148-5A187 181	5547016003	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.10143	-118.33155	08/29/2016 Changes to an approved set of plans. Changes have been clouded. Changes have been made to the lighting fixture counts and the Title 24 Compliance Forms. 02/05/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms. *****Previous Work Description*****CHANGE OF USE FROM RETAIL TO RESTAURANT.PC FOR ENERGY ONLY, TOTAL AREA 1,077 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24664	10041-10000-03614	13175 W MINDANAO WAY	90292	11	105B153   100	4212004006	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	07/20/2010 12:00:00 AM	ADDRESS	33.98463	-118.43781	T.I. for bank (Chase).  Install general and emergency lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24665	10041-20000-08910	71 N BEVERLY PARK	90210	5	156B161    52	4386013020	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2010 12:00:00 AM	05/15/2012 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.12462	-118.41843	Plan check new 2-story single family dwelling with 1200A service including guest house and tennis bar. Permit for guest house and tennis bar under #12041-10000-02202. (1 of  2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24666	15041-10000-24914	1727 E I ST	90744	15	033B213   881	7428033900	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	33.78255	-118.2401	PLAN CHECK FOR POWER FOR REPLACEMENT OF GENERATOR IN HAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24667	15041-10000-18288	1200 S CLUB VIEW DR 15th Flr	90024	5	135B157   112	4327024***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Expired	07/07/2017 12:00:00 AM	ADDRESS	34.06748	-118.42481	Energy plan check for a corridor ,design build, located at the north of 15th floor.  Lighting only, no equipment and receptacle involved.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24668	18041-10001-26777	653 E MILWOOD AVE	90291	11	108B145   951	4241005024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Expired	09/12/2023 12:00:00 AM	ADDRESS	33.99215	-118.46385	Change to approved set by adding more equipment on the floor plan. single line also being updated.(((PLAN CHECK FOR ROOF MOUNTED 3.0KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(PVI-3.0-OUTD-S-US-Z-A) WITH 10 PANELS(TRINAMOUNT TSM-300DD05A) )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24669	15041-10000-27657	3625 S VERMONT AVE	90007	8	120B197   967	5040029025	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.0224	-118.29173	PC for energy only. TI to an existing commercial bldg(AT&T dealer store). The scope of work includes: addition and relocation of light fixtures. Sq ft = 1754	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24670	12041-20000-00366	8401 N VAN NUYS BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM			PC Info Complete	01/17/2012 12:00:00 AM	ADDRESS	34.22308	-118.44896	T.I. for existing retail (The Children's Place).  Install indoor general/emergency lighting. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24671	19041-20001-19438	23029 W DOLOROSA ST pv1	91367	3	174B097   698	2042003038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.17062	-118.62873	expeditepv1install roof mounted pv system sized 10.7KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24672	19041-20000-29033	11139 N MARKLEIN AVE	91345	7	210B145   102	2664010015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.27302	-118.47098	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 8.82KW DC/7.6 KW AC. SCOPE OF WORK INCLUDES (28) HANWHA PV MODULES WITH P320 OPTIMIZERS,AND A SE7600 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24673	16041-10000-18886	4141 N ELMER AVE	91602	2	162B173   134	2366030013	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Expired	07/03/2018 12:00:00 AM	ADDRESS	34.1435	-118.37692	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(14)MODULES-LG LG315N1C-G4(14)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24674	17041-20000-20865	3814 N GLENEAGLES DR	91356	3	162B117   266	2180019019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.13912	-118.56429	PV1.  Install 13.44 kW roof mounted grid tied PV system.  (42) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24675	14041-10000-14746	331 1/2 E 1ST ST	90012	14	130-5A215 321	5161012012	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	02/25/2017 12:00:00 AM	ADDRESS	34.04992	-118.23998	CHANGE OF USE FROM RESIDENTIAL TO HOTEL. ALL CIRCUITS AND PANELBOARDS ARE CONSIDERED NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24676	13041-10000-05488	6330 W SAN VICENTE BLVD SUITE 300	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.06116	-118.36804	PLAN CHECK FOR LIGHTING AND POWER 3 STORY LOW RISE OFFICE SPACE/GYNECOLOGY CLINIC 3RD FLOOR. 3023 SQRFT. NO INVASIVE EQUIPMENT INDICATED ON E-4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24677	14041-20000-28177	432 N GENESEE AVE	90036	5	141B177  1328	5527027026	RD1.5-1-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.07915	-118.35825	PV1.  Install 4.40 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24678	18041-10001-19219	9857 N MASON AVE	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.24955	-118.58012	This is plan check only due to revision to master plan. Scope includes removal of one panel and redistribution of circuits from that panel to another. No changes in lighting and T24. Permit shall be covered under master.<<TI IN AN EXISTING STARBUCKS COFFEE. INSTALL LIGHTS, PANELS & CIRCUTS.PLAN CHECK FOR T-24 ENERGY ONLY.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24679	14041-10000-17622	15751 W ROXFORD ST STE I	91342	7	222B141    45	2604002022	[T][Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.30837	-118.47526	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 1211 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24680	18041-20000-32882	12218 N SARAZEN PL	91344	12	216B137    61	2609011011	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.29158	-118.49608	pv1install roof mounted pv system sized 10.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24681	19041-30000-04231	601 S FIGUEROA ST 43rd Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is common area restrooms on the 43rd floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 520 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24682	17041-10000-22946	1500 W PICO BLVD	90015	1	127-5A203 177	5135033033	CM-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Issued	03/09/2018 12:00:00 AM	ADDRESS	34.04367	-118.27515	PC FOR RETAIL TI  FOR AUTO PARTS SHOP TITLE -24 ENERGY ONLY. TOTAL AFFECTED AREA 8958 SQ.FT(indoor).  +16178 sq.ft (outdoors)SCOPE INCLUDES NEW LIGHTS AND RECEPTALCLES .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24683	14041-20000-02277	17100 W CALAHAN ST PV1	91325	12	198B133   591	2692019030	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.23631	-118.50588	pv1 single family dwelling. total system size 11.4 kw ac using 3 transformerless inverters nonstandard plan. using power optimizers. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24684	15041-20000-16378	940 S FIGUEROA ST basement-5th floor	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.04538	-118.26335	New service upgrade and distribution equipment for assembly occupancy. new design. This is core and shell clear out of existing building. TI package will be submitted at a later date. per building submittal, PC is accordance to 2008 building efficiency standards.project is in methane buffer zone. NOT A HIGHRISE PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24685	12041-10001-19851	905 E 8TH ST	90021	14	124-5A213  77	5146029039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.03645	-118.24647	REVISIONS TO PERMITTED SET OF PLANS-ADDED SUBPANELS TO PANELS 1B AND 2A  AND NEW CIRCUITS FOR INSTANT WATER HEATERSCONVERT 2-STORY WAREHOUSE TO OFFICE; CHANGE FRONT ELEVATION AND NEW INTERIOR WALL;SINGLE TENATPLANS DESIGNED WITH INTENT FOR FUTURE SERVICE UPGRADE SEE # 12041-10000-02674	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24686	13041-10000-24142	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	33.94955	-118.38342	$0 permit fee per Senate Bill 1222PV3. NEUTROGENA MANUFCATORING PLANT. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 99.470 KW DC.SELECTRICA PV185 INVERTER. 406  MODULES.  2 OF 2 BUILDING ( DIFFERENT ADDRESSES)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24687	14041-20000-00900	20539 W VENTURA BLVD	91364	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	33.9787	-118.31759	PC FOR T24 ENERGY ONLY. NEW LIGHTING TO REPLACE EXISTING. REDUCTION IN LOAD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24688	19041-20000-52857	20030 W SEPTO ST	91311	12	201B113    78	2726003049	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.25082	-118.56994	PV1.  Install 10.34 kW AC CEC roof mounted PV system.  (36) modules with 10 kW rated inverter.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24689	13041-20000-34045	14630 W WYANDOTTE ST	91405	6	186B149   789	2218023009	R3-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Apartment			12/06/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Expired	03/03/2016 12:00:00 AM	ADDRESS	34.20289	-118.45203	PV2 MICROINVERTERS. TOTAL SYSTEM SIZE 36KW. 144 MODULES AND MICROINVERTERSZero fees due to 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24690	19041-10000-18432	23367 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	08/24/2019 12:00:00 AM	ADDRESS	34.15846	-118.63421	Plan check to replace a previous approved/lost set, No permit fees paid under original 19041-20000-01866. Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to office. Total lighting area = 2,336 sq. ft.Note: Building application has been generated under 19016-20000-01372	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24691	17041-20000-05312	11427 N AMIGO AVE	91326	12	213B121   561	2871013024	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.27894	-118.5407	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (34) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24692	14041-10001-04678	12881 W FILMORE ST	91331	7	213B161   874	2533028034	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/02/2014 12:00:00 AM	ADDRESS	34.27768	-118.41374	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES:  CNADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24693	15041-20001-24352	22845 W CALVERT ST	91367	3	177B097   375	2039014042	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM			PC Approved	08/12/2015 12:00:00 AM	ADDRESS	34.18115	-118.62484	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 21.2 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24694	18041-20001-44443	5401 N SEPULVEDA BLVD BLDG b	91411	4	172-5A145  22	2250001020	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	34.16854	-118.46653	Expedite fee.PV2.  Install 53.95 kW roof mounted grid tied PV system.  (166) modules with (4) 11.4 kW rated string inverters.  System 1 of 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24695	15041-20000-14067	13860 W EUSTACE ST	91331	7	210B153   773	2616026005	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.26977	-118.4349	Plan check for PV roof mounted system micro-inverter 16 modules connected to 200A existing Panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24696	12041-10000-05296	808 W 58TH ST	90037	9	108B197   558	5001007002	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	01/02/2013 12:00:00 AM	ADDRESS	33.98934	-118.28723	New fire alarm system, with 116 devices in an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24697	19041-20000-51381	2346 N LYRIC AVE	90027	4	150B201  1453	5433019017	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.10336	-118.27454	PV1. INSTALL 11.34 KW DC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24698	17041-10000-23477	10247 N O'MELVENY AVE	91331	7	204B157   620	2646023047	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.25614	-118.42541	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM CONSIST OF (29) M250 MICROINVERTERS WITH MODULES. TOTAL SYSTEM SIZE =  7.25KVA	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24699	15041-20001-25325	6344 N TOPANGA CANYON BLVD A-1080	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM			PC Info Complete	09/10/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	09-10-2015 Change to approved set of plans. Changes include Delta 2 and track light in the corridor. {{{{{Plan check for power and Title-24 (energy).  Total area = 4,197 sq. ft.  T.I. to commercial first time tenant.  New lighting and recepticles.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24700	13041-20000-19816	13056 N ANGELES TRAIL WAY	91342	7	225B165    19	2580018***	RD6-1, T, Q	North Valley				1061.12	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.31003	-118.40418	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11 KW. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 44 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24701	08041-10001-22541	2402 E ANAHEIM ST	90744	15	030B213   113	7440002***	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM			PC Approved	03/25/2010 12:00:00 AM	ADDRESS	33.78054	-118.23195	REVISIONS TO APPROVED SET OF PLANS- REPLACE EMERGENCY UNIT EQUIPMENT WITH EMERGENCY INVERTER IN ROOM 146 WHERE NORMAL LIGHTING IS FROM METAL HALIDES RESTRIKE LUMINAIRES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24702	15041-10000-31919	2029 S CENTURY PARK EAST 17TH FLR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, ADDING NEW LIGHTING TO AN ELEVATOR LOBBY. SCOPE INCLUDES NEW LIGHTING. PC FOR ENERGY AND EMERGENCY LIGHTING ONLY. TOTAL SQ. FT. 278	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24703	18041-10000-05780	11442 N OSTROM AVE	91344	12	213B133   748	2697017015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.27854	-118.50702	PC FOR ROOF MOUNTED PV ON SFD. TOTAL SYSTEM SIZE 6.1KWDC /5.8KWACSCOPE INCLUDES 20 MODULES WITH MICRO INVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24704	10041-10000-06181	5333 W ZOO DR MARKET-STALL	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	9800.09	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Expired	12/13/2013 12:00:00 AM	ADDRESS	34.14867	-118.28623	PLAN CHECK POWER AND ENERGY FOR MARKET STALLS BUILDING PERMIT #08020-10000-02623	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24705	14041-20001-20815	7755 N QUIMBY AVE	91304	12	189B097   962	2014032020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2014 12:00:00 AM			PC Approved	08/11/2014 12:00:00 AM	ADDRESS	34.21164	-118.63076	Fee for expedite only.*****New roof mounted PV system, total system size 13.77KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24706	15041-10000-10067	9301 N TAMPA AVE 28A-29A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	1400 sq. ft. retail space TI in a mall.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24707	16041-30000-30842	11824 W JEFFERSON BLVD	90230	11	105B165   286	4220006029	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	33.98583	-118.4018	Plan check for Title 24 only in existing wear house. Load less than 400A and service equipment is rated at 400A. Total area; 6,717 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24708	15041-20000-25307	21800 W OXNARD ST Suite 910	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for Title 24 only in office remodel of existing high rise office. Al new lights, existing circuit. Total indoor area: 2,116 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24709	10041-10000-09700	13750 W ROSCOE BLVD	91402	6	192B153   772	2213016003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	08/10/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	ADDRESS	34.22148	-118.43301	INTERIOR REMODLING OF A RESTAURANT YOSHINOYAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24710	16041-10000-33558	11601 W WILSHIRE BLVD 7TH FLR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.05075	-118.45961	T-24, PC FOR ENERGY ONLY. INTERIOR OFFICE TI AT 7TH FLOOR OF (E) HIGH RISE OFFICE BUILDING. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3538 SQ. FT. B#16016-10000-20522	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24711	15041-20000-35220	14744 W BLACKHAWK ST	91345	7	204B149   185	2648010008	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.25803	-118.45386	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5KWac.(19)MODULES  KYOCERA#KU2656ZPA(1) INVERTER-ABB#PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24712	17041-20001-20266	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	12.26.2017 - Plan check for modifications to approved set. Change AC disconnects from 30A to 60A - see SLD sheet IE-04. Add sheet IE-06. Only changes.======pv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24713	17041-20001-23540	2208 N STRADELLA ROAD	90077	5	153B145   195	4377030002	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2017 12:00:00 AM			Reviewed by Supervisor	07/25/2017 12:00:00 AM	ADDRESS	34.11283	-118.46263	EXPEDITED PER APPLICANTS REQUEST5KW ENERGY STORAGE SYST.  + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.12 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24714	15041-20000-24954	7537 N VINELAND AVE	91352	2	186B173   375	2315013008	RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Apartment			08/04/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.20777	-118.37064	TI to new low rise 5 unit apartment building. Plan check for energy only. Adding new lights including emergency. Indoor and outdoor lighting. Total sqft. 10,751.Low voltage 2 floors,  power for new 5 unit  apartment building and smoke detectors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24715	15041-20001-34815	10300 W VENICE BLVD	90232	5	117B165    21	4208005020	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Info Complete	04/25/2017 12:00:00 AM	ADDRESS	34.02072	-118.40287	(1/7/2017)changes to an approved set of plans.  changes noted delta 1.  changes include service size downsized from 2000amp to 1600 amp. new 400 amp distribution board with futute panels and circuits.  plan check for power.Plan check for power and lighting. Project site is a new 5-story, 34-unit apartment building. Building has (2) levels of parking (1 below-ground and 1 above ground) and (4) levels of residential units. Service size 2000-amps. Total indoor lighting area = 18,500 sq. ft. and total outdoor lighting area = 1,750 sq. ft. Note: Building permit application has been filed under 14010-10000-03787	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24716	11041-10002-23452	20600 W VENTURA BLVD South-1-217	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.16715	-118.58204	IN APARTMENT UNITS , RECEPTACLES ARE ADDED AND LIGHTING FIXTURE IN THE BATHROOM CHANGES; OTHER ARCHTECTURAL CHANGES INSIDE SOME UNITS; SAME TYPE OF CHANGES IN COMMON AREAS; ADDITIONAL EXIT LIGHTS IN THE PARKING STRUCTURE((((((((((South Building of a New 217 unit Apartment building.  Building Permit is on 11010-10000-01956	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24717	19041-10000-01093	625 N RODS WAY	91340	7	216B161    20	2514002084	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.29281	-118.41694	REMOVE HID INDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24718	14041-10000-06723	735 S AVENUE 61	90042	14	150A233   119	5312024079	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.10542	-118.17943	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  2-STORY HOME. INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) TRINA SOLAR TSM-250PA05.18THIS PLAN HAS ALREADY AN EXPRESS PERMIT AND THIS APPLICTION IS PROVISION REGARDING FIRST PERMIT# 13041-20000-32619.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24719	19041-10000-46639	610 S KINGSLEY DR	90005	10	135B193   914	5503025007	CR-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	01/13/2021 12:00:00 AM	ADDRESS	34.06296	-118.30268	T-24 PLAN CHECK FOR A TENANT IMPROVMENT FOR RESTROOMS IN EXISTING BUILDING. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 412 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24720	14041-10000-02487	4726 E HUNTINGTON DR SOUTH	90032	14	142-5A231 104	5213019003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.08531	-118.18205	PLAN CHECK FOR T24 PART 6 ENERGY ONLY TO AN 369 SQ FT AREA RETAIL SPACE. SCOPE OF WORK < 400A. NO POWER PLAN CHECK REQUIRED. THIS PLAN CHECK IS IN REFERENCE TO PERMIT: 13041-70000-33862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24721	14041-10000-20847	165 S MISSION ROAD	90033	14	129A217   171	5172013004	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.04593	-118.22811	Title 24 plan check only.  Total area = 8,381 sq. ft. unconditioned and 2,596 sq. ft. conditionedReplacing existing lighting fixtures with new flourescents.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24722	14041-20000-25940	7142 S GLASGOW AVE	90045	11	099B173    53	4103017029	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.97095	-118.37243	MICROINVERTER STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24723	18041-10000-12984	815 E 106TH ST	90002	8	090B209  1038	6051020012	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	33.94024	-118.2603	PC FOR NEW ROOF MOUNTED PV SYSTEM ON SFD. SCOPE INCLUDES 16 HYUNDAI PANELS WITH 16  MICROINVERTERS ENPHASE IQ6 .TOTAL SYSTEM SIZE 4.64KWDC/3.84KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24724	18041-10000-13199	21240 W BURBANK BLVD BLDG 30	91367	3	174B105    40	2149016026	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.17307	-118.59314	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR S.C.I.F LAB. SUITE 1594. 3060 SQFTBUILDING PERMIT # 18016-10000-07655	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24725	13041-10001-27086	4717 N SANTA LUCIA DR	91364	3	168B101   974	2171022053	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.15309	-118.60459	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 2 STORY HOUSE. TRANSFORMER LESS INVERTER. UNGROUNDED SYSTEM. SYSTEM SIZE: 2.75kW.(11) TRINA SOLAR # TSM-250PA05.18(1) SOLAREDGE #SE3000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24726	13041-20000-34511	640 W 172ND ST	90247	15	066B201   252	6121011056	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	33.87535	-118.286	PV1 MICORINVERTERS. TOTAL SYSTEM SIZE 2.9 KWAC. 11 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24727	16041-10000-25329	1309 W SEPULVEDA BLVD	90501	15	045B197   144	7347018094	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	33.81485	-118.29961	PC FOR POWER AND ENERGY. NEW SIX STORY, 176 UNITS APARTMENT BUILDING. 6 TYPES APARTMENT WITH THE SAME PANEL TYPE. SCOPE OF LIGHTING INCLUDES OUTDOOR AND INDOOR: 150318 SQ FT.B# 15010-10000-00532	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24728	12041-10000-18196	1024 N SEPULVEDA BLVD	90049	5	141B141   142	4368010024	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.08205	-118.4732	Plan check for roof mounted 11.45KW Photovoltaic system. (5 strings) Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24729	18041-20000-01338	555 S FLOWER ST Suite 3450	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for Title 24 only. Project site is a suite on the 34th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,540 sq. ft.Note: Building application has been generated under 18016-10000-00446	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24730	16041-20001-31964	5200 S CENTRAL AVE	90011	9	108B209    95	5104003034	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	33.99574	-118.25623	Expedited per applicant request.Plan check for the roof-mounted portion of a PV2 roof-mounted & ground-mounted PV system. PV system is part of the LADWP feed in tariff (FIT) program. Roof-mounted portion is 56 kWac and consists of (2) 28 kWac inverters and (226) modules. Total system size is 323 kWac.Note: Ground mounted portion of the PV2 PV system can be found under application number 16041-20000-31971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24731	19041-20000-22240	22135 W ROSCOE BLVD LOT #35	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 35.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24732	15041-20000-27668	1910 S MAGNOLIA AVE #101	90007	1	126A201   175	5056027037	CM-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.03947	-118.28631	Plan check for power and energy for existing medical office addition of 2 exam rooms, nurse care room and remodel medical lab, pantry room, dispensory room. Total area: 820 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24733	14041-20001-30931	21806 W SIMION LANE	91304	3	186B105  1026	2110004006	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.06	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.20932	-118.60333	04/28/2016 Changes to an approved set of plans. Changs include the addition of (6) modules to one of the strings, changing the string size from (10) to (16). Other changes have been made to accomodate for the increased string size.*****Previous Work Description*****PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.7KW INTERCONNECTED WITH MSP.(22) SOLARWORLD 270W MODULES(22) ENPHASE 215 MICROINVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24734	12041-20000-00217	1520 W 183RD ST	90248	15	063B193   330	6108021031	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	03/13/2012 12:00:00 AM	ADDRESS	33.86444	-118.30366	Install PV system on roof of single family dwellling and upgrade service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24735	10041-10000-04898	4015 N RESEDA BLVD Fitness-Center	91356	3	162B121    10	2177032021	A1-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01, 1398.02	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.14338	-118.54088	T-24 and emergency lighting plan check for new fitness center and outside llighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24736	11041-10001-13651	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	08/29/2011 12:00:00 AM	ADDRESS	34.06664	-118.46903	TI IN AN EXISTING SCHOOL.  INSTALLING NEW PANELS, LOADS & LIGHTING. EPC FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24737	16041-20000-03934	20308 W MINNEHAHA ST	91311	12	207B113   280	2707017019	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.25999	-118.57592	Plan check for PV roof mounted system. System size: 5.0kW with 23 modules and 1 inverter(5.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24738	10041-20000-25797	1807 S BEVERLY GLEN BLVD	90025	5	132B157   730	4317001042	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			12/29/2010 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.05666	-118.42393	PLAN CHECK POWER AND ENERGY FOR NEW 14 UNIT APARTMENT BUILDING WITH 1200A SERVICE IN METHANE ZONE.  VARIANCE TO SEPERATE FIRE ALARM SYSTEM SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24739	13041-10001-32282	5506 N MORELLA AVE	91607	2	174B169  1086	2348005009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.17059	-118.38982	Expedited RSES plan check per applicant request.(((PV1, Install 4.5 kW DC roof-mounted solar array for a 2 story house , interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 18 modules Yingli YL250P-29b.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24740	17041-10000-22583	10250 W SANTA MONICA BLVD FC23	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for First Tenant Tenant improvement in existing core/shell space-Big Fish Little Fish	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24741	13041-10000-34559	18226 W ROSITA ST	91356	3	168B125   339	2184006018	R1-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.15767	-118.52987	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. NON-STD PLAN. SOLAR OPTIMIZERS. 4.68 kW DC.(18) LG MONO X LG260(18) SOLAR EDGE POWER OPTOMIZERS OP300(1) SOLAREDGE SE5000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24742	13041-10000-22577	8820 S SEPULVEDA BLVD	90045	11	096B165   989	4123001032	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	33.95653	-118.39597	Two story church, addition to existing fire alarm, 110 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24743	13041-10000-16128	11550 N GLENOAKS BLVD	91331	7	213B161   564	2524012024	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.27993	-118.41801	NEW 800A SERVICE AND CORE AND SHELL WORK FOR A 5000 SQ FT OF MARKET AND 2178 OF TENANT SPACE. NO LIGHTING IN SCOPE OF WORK (TITLE 24 PART 6 TO BE DONE WITH FIRST TIME TENANTS AT A LATER DATE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24744	10041-10000-14211	111 E UNIVERSAL HOLLYWOOD DR 15th floor	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.13855	-118.36112	T24 and emergency lighting plan check for the 15 floor.  Fire life safety variance was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24745	12041-10000-07725	10250 W CONSTELLATION BLVD suite 1600	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.05735	-118.41746	alterations in existing offices-new lighting and power circuitsplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24746	19041-20000-34151	19554 W TUBA ST	91324	12	204B117   239	2726009029	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.25659	-118.56003	PV1. INSTALL 9.25 KW DC SOLAR SYSTEM WITH (25) MODULES AND OPTIMIZERS AN (1) INVERTER (SE7600H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24747	18041-10000-44860	14822 W CHATSWORTH DR	91345	7	207B149     7	2615022***	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.26855	-118.45556	PLAN CHECK FOR A ROOF MOUNTED 6.0KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SE6000H-US) WITH 20 MODULES USING P400 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24748	15041-20001-15811	11680 W VICTORY BLVD	91606	2	180B169  1212	2335027002	C1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.18651	-118.38718	Main Service UPGRADE to 600A, PC for Power only. Partial permit under 15041-20000-38162(((Plan check for T24 ENERGY ONLY. Tenant improvement to mini mart and addition of office to the building. All work interior to building (no power being routed through/to hazardous location/service pumps). 1,953sqft.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24749	14041-20002-08393	15836 W LONDELIUS ST	91343	12	195B141   683	2672012048	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.22915	-118.47764	Modifications to approved set.  Removal of 3 modules from proposed design.  $0 submittal fee is due to fee caps via Senate Bill 1222. (((PV1. Roof-mounted PV System with 5.75kw with optimizer)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24750	18041-20000-18465	14839 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.29492	-118.45466	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24751	13041-10001-29470	20263 W INGOMAR ST	91306	3	189B113  1066	2107012042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.21171	-118.57515	Expedited plan check per applicnat request.(((((PV1, Installing roof-mounted solar array, interconnect with main panel. System size: 11.5 KW DC.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24752	14041-10000-01591	2226 3/4 S RAYMOND AVE	90007	8	123B197   302	5054018020	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Apartment			01/21/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.03547	-118.29741	PV1, Install 1.5 kW DC roof-mounted solar array on a two stories multi units home, interconnect with exsisting service panel. (1) Transformerless inverter(s): POWER-ONE AURORA PVI-3--OUTD-S-US. (6) Modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24753	15041-10000-34559	2510 W TEMPLE ST	90026	13	138A205   190	5157008029	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.07192	-118.27348	NEW FIRE ALARM SYSTEM WITH 120 FA DEVICES AND 0NE FA PANEL. NEW 4-STORY, 47-UNIT MIXED USE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24754	17041-30000-33487	2029 S CENTURY PARK EAST 4th Floor-RR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing highrise men and women restroom 4th Floor. Total area: 410 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24755	14041-10000-17522	13163 N PHILLIPPI AVE PV1	91342	7	225B153   467	2504016036	RA-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.30968	-118.44312	PLANCHECK PER INSPECTORS REQUEST. EXPRESS PERMIT PULLED UNDER 14041-20000-15472PV1. ROOFMOUNTED SOLARD SYSTEM. PHOTOVOLTAIC SYSTEM (6.375KW - USING 6KW INVERTER). TRANSFORMERLESS UNGROUNDED STANDARD PLAN.(25) TSM 255 MODULES(1) POWER ONE AURUOA PV1 6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24756	16041-10001-19374	11800-11818 W WILSHIRE BLVD	90025	11	129B145   804	4263007123	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.04771	-118.46271	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO DEVICE COUNTS OF DETECTION DEVICES AND NOTIFICATION DEVICES. CHECKING NEW BATTERY CALCS. CHARGING INSPECTION FEE TO REINSPECT ALTERATION FROM ORIGINAL SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24757	17041-20000-25491	9369 N BALCOM AVE	91325	12	198B129   134	2766003017	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.2411	-118.52173	PV1.  Install 10 kW roof mounted grid tied PV system.  (34) modules with (1) 10.0 kW rated central inverter.  Central inverer standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24758	13041-10001-34470	6316 N TOPANGA CANYON BLVD BLD # B	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	2/18/2015 Changes to an approved set of plans. Changes include relocating load circuits. No new circuits or panels added. All changes are clouded. Approved for submittal per F.Y.*****Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING BBUILDING PERMIT # 13010-10000-02905.New 2 STORY retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24759	12041-10000-20636	8940 N WOODMAN AVE	91331	6	195B153   376	2640016005	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			Corrections Issued	11/14/2012 12:00:00 AM	ADDRESS	34.23234	-118.43797	65 kw roof mounted PV for a commercial BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24760	12041-20000-24609	9654 N COZYCROFT AVE	91311	12	201B109   242	2748003088	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM			PC Approved	10/15/2012 12:00:00 AM	ADDRESS	34.24578	-118.58185	Tenant Improvement in office space. Title 24 Plan check for energy only 465 sq ft. (No emergency lighting per applicant)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24761	13041-10001-13953	5711 W CENTURY BLVD PACIFIC-BALLRM	90045	11	093B169   327	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	33.94573	-118.38128	MODIFICATION TO APPROVED SET OF PLANS. CHANGE TO CIRCUITING OF LUMINAIRES. NO CHANGES TO TITLE 24. 5715 SQUARE FEET.***************************************************************************13041-10000-13953 WORK DESCRIPTION: PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT FOR EXISTING JR. BALLROOM. PLACE OF ASSEMBLY MORE THAN 100 OCCUPANTS. GROUND FLOOR HILTON HOTEL. VARIANCE ON FILE FOR CUSTOM PENDANT FIXTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24762	13041-10000-26142	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.05069	-118.24861	New 300 kVA XFMR and 1200A distribution board for future Grand Central Market tenants.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24763	17041-20000-32818	7348 N ETHEL AVE Units A&B	91605	2	186B161   541	2327015007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	PIN	34.20432132	-118.41768776	Plan check for power and energy. Project site is a new commercial building. Project scope is a first time tenant. Total lighting area = 2,208 sq. ft.Note: Building application has been generated under 16014-20000-04290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24764	16041-10003-00798	232 E 2ND ST	90012	14	129A213    28	5161024034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM			PC Approved	09/30/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	09/30/2016.pc for power. changes . relocation of panels. addition of one fan, and update the panel schedule and load calculation. plan check only. changes under delta 3.<<<<<Plan check for 1st time tenant for Starbucks Coffee in mix use building(Multi units dwelling and commercial). Total area: 1,827 sq ft.Building Application #: 15016-10000-28333>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24765	15041-20001-02647	12500 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/31/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	expedite per customer request.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24766	14041-10000-35867	15138 W SATICOY ST	91405	6	186B145   169	2221002007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.20832	-118.46315	PV1 4.085KW Enphse microinverter roof mounted system with (19) Sunmodule SW270 modules and Enphase M215 microinverters interconnecting through a load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24767	11041-20000-05946	15821 W VENTURA BLVD 6th Floor	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM	03/25/2011 12:00:00 AM		Permit Finaled	06/28/2011 12:00:00 AM	ADDRESS	34.15584	-118.47812	T.I. to high rise building.  Install general lighting in restrooms of 6th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24768	14041-20000-05344	2664 N HYPERION AVE	90039	4	150A205    45	5434037020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	PIN	34.106966	-118.27191013	PC FOR T24 ENERGY ONLY. NEW LIGHTING. RETAIL SPACE. TOTAL AREA 1069 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24769	19041-20002-06813	9315 S LINCOLN BLVD PV1	90045	11	096B161   831	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	33.95584	-118.41565	System redesign.  Reduction in number of modules, type and quantity of inverters, elimination of trasnformer.  New system size is 59.50 kW DC / 53.54 kW AC CEC with (163) modules, (1) 43.2 kW inverter, and (1) 9 kW inverter. System 2 of 3.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24770	17041-10000-35355	11355 W FOOTHILL BLVD	91342	7	210B173    20	2530022184	(Q)C1-1VL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.27622	-118.37875	775 sf addition to retail commercial building; new panel and new circuitsPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24771	11041-10000-20633	1505-1515 S PENMAR AVE BLDG 27	90291	11	111B145    36	4243001040	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.00403	-118.45851	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24772	16041-10002-06900	4550 N VAN NUYS BLVD	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.15445	-118.4485	PC FOR CHANGES TO APPROVED SET. CHANGES INCLUDE 2 NEW PANELS FOR FUTURE STARBUCKS. THIS IS ADDITION TO CORE AND SHELL SCOPE OF WORK. CHANGES NOTED DELTA 2 AND 4 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24773	15041-20000-03565	7500 N GLENOAKS BLVD 1ST. FL	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.20696	-118.3417	PLANCHECK FOR T24 ENERGY. WOODBURY UNIVERSITY MILLER HALL SCHOOL. NEWLY CONNECTED LOAD < 400 AMPS. 5870 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24774	18041-10000-01206	14630 W PLUMMER ST	91402	6	198B149    69	2650026900	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.2424	-118.45147	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24775	15041-30000-40322	541 S SPRING ST #131	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.04657	-118.2507	Title 24 plan check only.  Total area = 463 sq. ft.     T.I. to existing commercial space.  New bagel shop.  Lighting, receptacles, and cooking equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24776	14041-20000-22476	16826 W KLEE ST	91343	12	195B133   299	2688029057	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.23093	-118.49923	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.2kW(2) ABB PVI-3.6-OUTD-US-Z-A  transformerless inverter(38) Kyocera #KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24777	12041-10000-17925	15410 W COVELLO ST	91406	6	186B145   258	2222014102	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.20742	-118.46885	Plan check for PV system. SFD. 5.886 kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24778	16041-20002-38511	12205 N HONDERO CT	91344	12	219B125   106	2601074013	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.29526	-118.52723	11/29/2016 Changes to an approved set of plans. System size has increased from 15 kWac to 15.2 kWac. Module count has remained the same.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (2) inverters, (66) modules, (1) load center, and (2) combiner boxes.Note: $0.00 permit fees due to Senate Bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24779	13041-10001-10684	10640 W RIVERSIDE DR	91602	4	165B177   104	2423003034	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.15205	-118.36286	PV2 11.52KW. 48 MODULES&MICROINV ON NEW CARPORT STRUCTURE. verify the btrc .(48) enphase m215-60-2LL-S22 microinverters. (48) SHARP ND-240QCJ PV SOLAR MODULES. on a new carport structure. construct carport sturcture with four posts and footings and which covers 920SF. install associated junction boxes, conduit, conductors and grounding. install (1) combiner subpanel, 1 square D DU222RB AC disconnect and install OCPD in existing panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24780	16041-10000-04118	600 S GAFFEY ST	90731	15	015B197   365	7451036001	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	33.73855	-118.29214	FULL PC FOR A NEW 1-STORY  RESTAURATN BLDG, JACK IN THE BOX. SCOPE OF WORK INCLUDES NEW 600 AMP SERVICE AND ELECTRICAL EQUIPMENT. TOTAL SQ. FT. 2823.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24781	11041-20000-17169	21200 W OXNARD ST	91367	3	177B105    75	2149002008	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.17905	-118.59389	PLAN CHECK FOR NEW 150KW STANDY-BY GENERATOR, 600A AND 400A DISTRIBUTION BOARD, XFRMR, PANELS, AND EQUIPMENT FOR PHASE III OFFICE TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24782	19041-20000-43218	2049 S CENTURY PARK EAST 31TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Issued	10/25/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 energy only, lighting, newly connected load less than 400A. Total area: 23187 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24783	19041-10000-07523	333 S GRAND AVE #2225	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	T-24 PC FOR A TI IN AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 4639 SQ.FTB#19016-10000-02055	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24784	19041-20000-49677	16800 W ADLON ROAD	91436	5	165B133   441	2291011023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.14661	-118.49895	PV1 PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 9.92 KW DC/7.6 KW AC. ESS SIZE IS 9.8 KWH. SCOPE OF WORK CONSISTS OF (31) PV MODULES WITH OPTIMIZERS, A 5 KW TRANSFORMER, A 7.6 KW INVERTER, A SUB PANEL, AND A 9.8 KWH BATTERY	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24785	18041-10000-43142	132 N WESTERN AVE UNIT A	90004	10	138B193   775	5517005003	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2114.10	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.07476	-118.30898	TI IN AN EXISTING (NON-MEDICAL) MASSAGE PARLOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BUILDING PERMIT:  18016-10000-30502	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24786	16041-10001-38868	15503 W VENTURA BLVD suite 150	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	34.15504	-118.4723	Full plan check for a medical office located in the first floor of a three-story commercial building.Scope covers half size of the floor with new lighting, receptacles and equipment;  Total area is 11,667 SQ FT.   (( 04-26-2017   M.Z    title 24 changed , added more emergency lighting ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24787	14041-10000-34485	850 W WASHINGTON BLVD	90007	1	124-5A203  64	5124020022	[Q]C2-2-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	PIN	34.0363201	-118.27708332	PV2.  Install 23.1 kW DC utility-interactive, rooftop-mounted PV system.  3 Sunnyboy 6000TL Transformerless inverters. Changes on plans include: balanced three phase conection of inverters, PV wire per LAETL research reports, and update of inverter output calculations.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24788	17041-20000-12245	6932 N GROSS AVE	91307	12	183B093   567	2028013004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.19499	-118.64003	PV1.  Addition of (12) modules to (E) roof mounted grid tied PV system and upgrade of inverter to (N) 7.6 kW AC rated inverter with power optimizers.  (N) system modules on detached garage.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24789	18041-10000-08687	1005 S MATEO ST	90021	14	123A217   204	5166019004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.03128	-118.23244	PC FOR POWER AND ENERGY FOR A CHANGE OF USE FROM WAREHOUSE TO Nursery (plant) AND INTERIOR REMODEL (IT). SCOPE INCLUDES NEW 600A  120/240 3PH  WITH NEW PANELS CIRCUITS EQUIPMENT AND LIGHTS. TOTAL AFFECTEED 49391 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24790	16041-20001-03230	1556 N HAZELWOOD AVE	90041	14	157-5A223  54	5474014017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	34.12463	-118.21435	Expedite per applicant request{{{{{{{Plan check for PV roof mounted system. System size: 5.7kW with 23 modules and 23 microinverters. PV connect to Supply side  of the service. PV ready service panel data sheet is provided.}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24791	15041-10000-11592	2029 S CENTURY PARK EAST 1900N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE PERFORMED IN SUITE 1900N.  TOTAL SQUARE FOOTAGE 10585.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24792	18041-20004-01171	1942 N SAN YSIDRO DR	90210	5	150B157   163	4384030012	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.10647	-118.42415	Fees $ 0.00 due to Sanate Bill 122205-14-2018 Changes to an approved set of plan. Changes include relocate AC Disconnect and inverter size from Delta Solivia 5.2kW to Solaredge 7.6kW and 3.8kW. Reduced number of modules from 47 to 45 modules.  Update system size: 14.175 KW. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24793	10041-20000-05836	6744 W HILLPARK DR	90068	4	154-5A185  11	5549004***	RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.11848	-118.34068	installing emergency lighting and exist sign in an apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24794	19041-20001-42607	5360 N RHEA AVE	91356	3	171B121    86	2161009005	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.16855	-118.54187	12-04-2019 Changes to an approved set, Changes include change conductor size to # 8AWG between inverter to MSP. All changes has been clouded.Plan check onlyFees $0.00 due to california senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24795	13041-10000-31043	1008 S CROCKER ST	90021	14	124-5A211 262	5132010050	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.03435	-118.25052	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  1456 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24796	14041-10002-34264	410 N LA CIENEGA BLVD	90048	5	138B173    27	5514001011	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	34.07843	-118.37638	Plan review of changes made in the field as shown on revised set of plans ansd mentioned in permit correction letter((((((((((Full plan check for office T.I  in a 2-story building including new 800-Amp service upgrade	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24797	17041-10000-43691	2554 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	04/02/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.10372	-118.259	PC for T24 only for restuarant TI. Installing new circuits and equipment. B# 17016-10000-26093	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24798	18041-10000-38784	1932 S STAUNTON AVE	90058	9	118-5A213 110	5167013020	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Issued	10/11/2018 12:00:00 AM	ADDRESS	34.0193	-118.24131	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24799	17041-20000-38130	11335 W DONA DOROTEA DR	91604	2	156B169    99	2381007029	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.12722	-118.38066	"""0$ permit fees due to senate bill 1222""Plan check for solar pv system, roof-mounted array on SFD.Total system size: 15.2kW ungrounded.(2) 7.6kW SolarEdge inverters(57) 330W pv modules.(57) 400W power optimizers."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24800	13041-10001-33017	9050 W OSWEGO ST	91040	7	207B185   238	2547029002	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.26439	-118.32814	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 6.5KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(26) TRINA SOLAR # TSM-250(26) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE6000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24801	16041-10000-19553	4502 S NORMANDIE AVE	90037	9	111B197   254	5017002001	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	Commercial			06/03/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.00252	-118.29999	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN EXISTING RETAIL SPACE ON THE 1ST FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR THE STORAGE AREAS. TOTAL AFFECTED AREA IS 535 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24802	16041-10000-26946	8639 N RESEDA BLVD	91324	12	195B125   949	2785004033	C2-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.22759	-118.5363	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (OUTDOOR) 8304  SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24803	19041-10000-45665	17401 W VENTURA BLVD	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	05/26/2021 12:00:00 AM		Permit Finaled	09/10/2021 12:00:00 AM	ADDRESS	34.16136	-118.51189	FULL PC FOR POWER AND ENERGY. NEW MAIN DISTRIBUTION PANEL RATED 1200A, WITH 4 NEW PANEL BOARDS, AND A XFMR WITH A SIZE OF 75 KVA. TOTAL AFFECED AREA IS 18409 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24804	16041-10000-22309	8401 N VAN NUYS BLVD #66	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.22308	-118.44896	MALL RETAIL TI - new lighitng. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24805	15041-20000-10429	601 S FIGUEROA ST Suite 1400	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for energy only. TI to existing office space on the 14th floor (high rise building). New and relocated lighting (incl. emergency), new receptacles. 6,780sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24806	19041-30000-00217	8927 N BAIRD AVE	91324	12	195B125   323	2770006005	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Re-Activate Permit	11/07/2019 12:00:00 AM	ADDRESS	34.23266	-118.53741	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (1) battery back-up unit and (1) load center onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24807	18041-10000-36404	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.01366	-118.28294	INSTALLING A 300A  CB IN EXISTING DIST BOARD TO SUPPLY A FEEDER TO A 300KVA 480V/120/208V TRANSFORMER TO A NEW 600A DIST BOARD FOR FUTURE NEW FOOD SERVICE AREA LOADS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24808	10041-10000-21002	3763 S HILL ST	90007	9	117A203   124	5122028009	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	ADDRESS	34.01507	-118.27803	New Fire alarm system. Plan check is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24809	09041-10001-19933	1948 W COLORADO BLVD	90041	14	162A223   108	5686006005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM			PC Approved	09/13/2010 12:00:00 AM	ADDRESS	34.13899	-118.21014	Plan was reviewed for T-24 and emergency lighting only to replace previously approved plans.  The extent of work is to change from retail to restaurant and upgrade the service from 100 amperes to 200 amperes.  The electrical installation was not evaluated by plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24810	12041-20000-21589	14222 W OXNARD ST	91401	2	177B153   886	2245018008	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	34.17926	-118.44294	"New rooftop photovoltaic system added to an existing commercial building with an existing photovoltaic system.  System is an ungrounded, transformerless system.      ""COMPLY WITH DEPARTMENT ORDER effective date04/13/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  CEIS Case Number is 76235. (Created: IMSV7 / 04-09-09)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 78643  -- ElectricalINVESTIGATION FEE DUE: CEIS Case Number is 76235."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24811	18041-20001-37403	1344 N MALTMAN AVE	90026	13	144A203   342	5427028013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM			PC Approved	10/17/2018 12:00:00 AM	ADDRESS	34.08738	-118.27822	Expedited plan check fee.PV1.  Install 20.3 kW roof mounted grid tied PV system.  (55) modules with 7.6 and 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24812	14041-10000-34727	8556 S EMERSON AVE UNIT 3	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	02/24/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 3 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24813	12041-10001-08498	1734 E 41ST ST	90058	9	114A213    88	5116029006	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.00788	-118.24202	cold storage bldg, new service, panels, copressors. title 24 already approved.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24814	17041-20001-40019	9210 N SHOSHONE AVE	91325	12	198B129   313	2766010014	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.23817	-118.51766	12.7.2017 - Plan check for modifications to approved set. Change pv interconnection to supply side tap. Main service panel is existing 200A instead of new 225A. Update single line diagram and roof plan. Changes clouded. Sheets B1, B2, and E1.=====PV1.  Install 11.52kW roof mounted grid tied PV system.  (36) AC modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24815	15041-10000-23217	5171 W 21ST ST	90016	10	126B177  1144	5063002009	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.03947	-118.35399	PV1, INSTALL 6.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY. (24) MODULES: KYOCERA KU2656ZPA(1) ABB PVI-5000-OUTD-US-Z-D	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24816	13041-20000-21971	7855 N HAYVENHURST AVE PV-2	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.21329	-118.49262	PV-2. Commercial roof=top installation. Zoning originally cleared on 13041-10000-04532. Check for variance for 2nd dedicated PV service. Bipolar PV. Isolation transformers must be included on separate application (two 333kVA transformers).0 permit fee was due to 2012 senate bil # 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24817	18041-20000-19570	5990 N SEPULVEDA BLVD #650	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.17911	-118.46588	Tenant improvement for commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24818	15041-20000-33423	16964 W ENCINO HILLS DR	91436	5	159B133    74	2287005059	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			Reviewed by Supervisor	10/23/2015 12:00:00 AM	ADDRESS	34.13479	-118.50213	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (50) modules, and (1) load center. Main service panel size is 400 amps.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24819	18041-20000-19173	6200 N CANOGA AVE 205-212	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.1833	-118.59719	Plan check for Title 24 Energy only in existing office space. Total area: 1553 sq ft.B#18016-20000-11934	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24820	12041-10000-18308	12428 W JEROME ST	91352	6	195B165    53	2629017018	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.23463	-118.40359	Plan check for single family dwelling. Solar Edge Power Box (+1 PC hour for submittal and +1 Miscellaneous Permit for Inpection period). 4.56kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24821	19041-20000-34176	20618 W WOOD ROSE CT	91326	12	219B109   550	2701102040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.29544	-118.58301	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24822	13041-10000-22029	2312 W BAXTER ST	90039	13	145-5A207  61	5422003017	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.09377	-118.26077	PV1. ROOF MOUNTED PHOTOVOLTAIC SYSTEM. 18.109 KW. MICRO INVERTER SYSTEM ( ENPHASE M215)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24823	14041-10001-14472	6268 W PRIMROSE AVE	90068	4	151-5A189 226	5586001036	R1-1	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.10966	-118.32559	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 7.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER, WITH OTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24824	16041-10001-13665	14379 W BEAVER ST	91342	7	219B149   591	2507023020	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	05/19/2016 12:00:00 AM	ADDRESS	34.29597	-118.44678	05/19Changes to an approved set of plans. PC for  a new solar system on existing residential roof-top. Total system size is 5.0kWac.NOTE: PERMIT PAID UNDER PCIS#16041-10000-13665((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24825	15041-20000-16546	9506 N PENFIELD AVE	91311	12	198B113    27	2761027017	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	06/27/2015 12:00:00 AM	ADDRESS	34.24324	-118.56945	Plan check for PV roof mounted system. System size: 6.8kW with 2 inverters (3.8kW and 3.0kW) and 31 modules (Standard plan is being use)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24826	16041-10001-20255	1901 N ROWAN AVE	90032	14	135A229    60	5215018011	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.06511	-118.18825	Expedite fees only.Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10.8 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24827	18041-20000-40293	5203 W HOLLYWOOD BLVD	90027	13	148-5A195  56	5544010026	C2-1D	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.1019	-118.30367	Plan check for Title 24 only in existing space T.I. Pet Store. Total area: 5282 sqs ft. B#18016-20000-31727	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24828	14041-20000-23017	537 E VENEZIA AVE	90291	11	108B145  1638	4237003009	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	33.98952	-118.45973	pv2 commercial solar install rooftop, total system size 15 kW AC.  Transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24829	19041-10000-01872	25600 S DODGE AVE	90710	15	036B197   925	7413033039	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.79189	-118.2888	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24830	18041-10000-13134	6429 W SELMA AVE	90028	13	148-5A187 308	5546007018	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Issued	06/01/2018 12:00:00 AM	ADDRESS	34.09988	-118.33062	NEW4 STORY PARKING STRUCTURE WITH RETAIL ON THE 1ST FLOOR IN A LOW RISE BUILDING.NOTE THAT ENERGY COMPLIANCE FORMS WERE NOT WITH THE SUBMITTED PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24831	10041-10000-04221	725 S FIGUEROA ST 3RD FL	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	34.04886	-118.26071	TENANT IMPROVEMENT IN THE REST ROOMS ON THE 3RD FLOORPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24832	13041-10000-11506	3631 W 3RD ST	90004	10	135B197   158	5518022010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	PIN	34.06923017	-118.29517502	TI for dental office.  1 story bldg.  1562 sq ft.  Power and energy plan check on account of healthcare facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24833	15041-10000-33316	8756 N VANALDEN AVE	91324	12	195B121   324	2784003026	M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM			Reviewed by Supervisor	11/17/2015 12:00:00 AM	ADDRESS	34.22981	-118.54906	PC FOR POWER ONLY, 2000AMP  SERVICE UPGRADE TO AN (E)  FOOD MANUFACTURING WAREHOUSE. 4 NEW PANEL AND MOTOR CONNECTED TO SWITCH GEAR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24834	18041-10000-48053	4837 E HUNTINGTON DR NORTH	90032	14	142-5A233  36	5213002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	11/15/2021 12:00:00 AM	ADDRESS	34.08619	-118.17919	PLAN CHECK FOR POWER AND ENERGY FOR - EXPAND ARROYO VISTA FAMILY HEALTH CENTER REMODEL EX'G/VACANT MEDICAL CLINIC (PACIFIC ALLIANCE), CONVERT EX'G COMMERCIAL USE (DENTAL OFFICE, WIC OFFICE, AND VACANT MARKET) TO PRIMARY CARE CLINIC (OSHPD 3) - TOTAL NEW CONNECTED LOAD OF APPROX 700A ON A NEW 800A 3 PHASE DISTRIBUTION SYSTEM WITH ASSOCIATED EQUIPMENT. TOTAL AFFECTED AREA = 10385 SQ FT.  B#18016-10000-40481	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24835	10041-10000-19084	4151 W 3RD ST # A-2	90004	4	135B193   203	5517014018	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20, 2118.01	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	01/07/2011 12:00:00 AM	PIN	34.06917421	-118.30448492	"TI IN RETAIL SPACE, PLAN CHKIS FOR TITLE 24.   ""COMPLY WITH DEPARTMENT ORDER effective date 08/20/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24836	14041-20000-13171	21700 W OXNARD ST Ste 1770	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for tiltle 24 and emergency lighting only on suite 1770	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24837	17041-10000-23260	2720 E WHITTIER BLVD	90023	14	123A223   102	5189011018	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.0323	-118.21149	Title 24 plan check.  Replace HID fixtures with new LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24838	11041-10001-09954	751 N ECHO PARK AVE	90026	13	138A209    47	5404015900	OS-1XL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.07242	-118.25998	((((((((((((((((((((((((((((  8-2-12   Installing conduit and cable for the future transformer in the bathroom , ti for future.    )))))))))))))))))))))))))AT THE ECHO PARK LAKE, REPLACEMENT OF FOUNTAIN PUMPS, STORM  PUMPS AND NEW OUT SIDE LUMINAIRES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24839	14041-10000-07098	1240 S NAOMI AVE	90021	14	121-5A213  54	5130006900	PF-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM			Corrections Issued	03/29/2014 12:00:00 AM	ADDRESS	34.02783	-118.24431	change of engineer and contractor. Power and energy plan check. previous description 12041-10000-06291: Plan check for installion of new 1600A service, switchboard for new photovoltaic system interconnection, and T24 Energy for new carport lighting. Existing building load to remain.  Photovoltaic system plan check  under #12041-10000-06288	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24840	13041-10000-15323	380 WORLD WAY T24-NG	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Info Complete	08/14/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	FIRST TIME TENANT AT TOM BRADLEY INTERNATIONAL AIRPORT. EXPRESS PERMIT WAS PULLED UNDER APPLICATION NUMBER 13041-10000-09503. TI- BRANCH CIRCUIT & LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24841	11041-20000-04488	6301 N OWENSMOUTH AVE 4,5,6,8,9-FLOORS	91367	3	177B105   123	2146029016	WC	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	34.18467	-118.60176	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT 4TH, 5TH, 6TH, 8TH, AND 9TH FLOOR RESTROOMS. NEW LIGHTING ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24842	18041-10000-40839	16180 W MULHOLLAND DR	90049	11	159B141   395	4490003003	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.12952	-118.48499	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24843	11041-10000-06328	1636 S BEVERLY GLEN BLVD	90024	5	148-5A153 421	4371043013	RE15-1, [Q]R3-1-O	West Los Angeles	Bel Air - Beverly Crest, Westwood	Bel Air - Beverly Crest	YES	2612.00, 2657.00	Electrical	Electrical	Apartment			06/22/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.05899	-118.42473	New 16 unit 4 story apartment building.  The building is in a Methane Zone: Level 1 less than 2 inches of water.  Exhaust fans shall be separately switched from lighting systems, typical.  Wall receptacles shall be installed so that no point along the wall line shall be more than 6 feet from a wall or floor receptacle.  A variance to separate the electrical and fire alarm plan check was submitted on July 15, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24844	14041-10000-14154	5520 W SAN VICENTE BLVD	90019	10	129B177    40	5085017001	C2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.05373	-118.3547	PLA N CHECK FOR POWER AND ENERGY FOR RENOVATION OF EXISTING MARKET 600A RATED EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24845	17041-10000-13363	1210 N CHEROKEE AVE	90038	4	144B185   440	5532002034	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.09285	-118.3351	T24 ONLY, REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 1168 SQ FT, OUTDOOR AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24846	14041-20000-02331	15735 W WYANDOTTE ST	91406	6	186B141   876	2206037***	(T)(Q)RD3-1, R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Expired	02/22/2016 12:00:00 AM	ADDRESS	34.20314	-118.47621	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC. USING SOLAR OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24847	15041-20001-18024	13400 N GLENOAKS BLVD	91342	7	225B145   115	2502028020	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.31591	-118.46014	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 175A.System size: 11.4kW. Ungrounded system. Using 300W power optimizers. (53) 260W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24848	14041-20000-22436	4528 N MAMMOTH AVE	91423	4	168B157   796	2271007011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.15391	-118.43244	PV1.  Install 4.4 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24849	14041-20000-21579	13020 W GOLETA ST	91331	7	204B161   319	2623015005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.2557	-118.41623	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTA OF 14 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24850	15041-10000-19320	7618 N SAN FERNANDO ROAD	91352	2	186B177    51	2405006019	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.2101	-118.3548	T-24 ONLY, REMOVING HID LIGHT FIXTURES WITH LED FIXTURES TO (E) BUILDING AND WIRING. TOTAL SQ. FT. 2896	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24851	13041-10000-17112	5932 W CENTURY BLVD 2nd floor	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM			Reviewed by Supervisor	07/03/2013 12:00:00 AM	ADDRESS	33.94435	-118.38715	pc for power and energy . for LAX united airlines - avairpo PM office. OFFICE BUILDOUT IN EXISTING 2ND FLOOR STORAGE ROOM. PAC-1 has (2) 10.4 HP , (1) 5 HP , (2) 0.5HP, (1) 0.75HP [MCA is 53A] per applicant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24852	16041-10000-44932	3553 W CASITAS AVE LOT 2	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12096	-118.257	Plan check for Power 11 buildings SFD live work  2 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 2 of 11Note: Master Application Lot 2 type B,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24853	17041-20000-09732	919 S ALBANY ST 1ST FLOOR	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.04913	-118.27045	PLANCHECK FOR T24 ENERGY. TI TO (E) FOUNDERS HALL BLDG. PHASE 2 FIRST FLOOR. 3436 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24854	13041-20000-05180	7201 N BALBOA BLVD	91406	6	183B133    69	2227003026	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.20147	-118.50132	Plan check for energy and emergency lighting. Low-rise commercial. Speedy Cash #124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24855	13041-10000-20556	8911 S SEPULVEDA BLVD	90045	11	096B165  1035	4122036031	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	33.95557	-118.39645	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. TENANT IS AN ANIMAL HOSPITAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24856	17041-10000-29265	338 E CANNERY ST	90731	15	015B205     7	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	33.7402	-118.26567	PC FOR FA SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24857	19041-20000-32427	11727 W PICO BLVD	90064	11	123B149   674	4260029031	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.03144	-118.44643	T24 PLAN CHECK FOR EXISTING RETAIL STORE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1000 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24858	15041-20000-21280	11846 W BLYTHE ST	91605	6	189B169   358	2310022026	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.2147	-118.3915	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW, CENTRAL STANDARD INVERTER PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24859	17041-10000-14096	655 S MAPLE AVE	90014	14	127-5A211 214	5148022010	C2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Issued	04/28/2017 12:00:00 AM	ADDRESS	34.04277	-118.24915	Remove Metal Halide fixture and replace with new LED fixrures- T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24860	19041-20000-12275	6178 N SEPULVEDA BLVD	91411	6	177B145   358	2242025001	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Issued	12/11/2019 12:00:00 AM	ADDRESS	34.18281	-118.46593	ti to an existing commercial space.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24861	13041-10000-10744	3852 N WOODCLIFF ROAD	91403	5	163-5A145 172	2281013006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	34.14066	-118.46814	pv1 single family dwelling. photovoltaic system using enphase m215 microinverter. total system size 5.1 kw. using 24 modules. roof mounted array. upgrade main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24862	18041-20000-28007	12462 N MARVA AVE	91344	12	219B129   288	2601050015	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.29786	-118.51808	Plan check for PV roof mouted system, system size: 10kW with 41 modules and 1 inverter(10.0kW) connected to 225A panel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24863	10041-10000-10926	12975 N BRADLEY AVE	91342	7	222B145   166	2506003021	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM			PC Approved	06/21/2010 12:00:00 AM	ADDRESS	34.30539	-118.46035	T.I. IN (E) OFFICE AREA. Plan check for T24 and energy. (Permit # 10041-10000-10389)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24864	16041-10000-04152	14823 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.17768	-118.45525	PC FOR ENERGY AND POWER.  TENANT IMPROVEMENT FOR A PRODUCTION STUDIO OFFICE. UPGRADING SERVICE. ADDITION OF TWO 400 A BREAKER AND ONE 100 A PANEL AND A NEW UPS. TOTAL AREA 17460 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24865	12041-10000-11714	7801 W MELROSE AVE	90046	5	141B177   529	5527010013	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	05/22/2012 12:00:00 AM	ADDRESS	34.08391	-118.35962	Plan check T24 Energy. Exterior wall lighting (facade lighting) for commerical retail building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24866	17041-10000-25052	3310 W ADAMS BLVD	90018	10	123B189   716	5052015028	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.03243	-118.32029	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AREA IS 37600 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24867	13041-10000-35672	16752 W VINTAGE ST	91343	12	204B137  1004	2685011002	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.25188	-118.49778	PV1, Install 12.25 kW DC roof-mounted solar array for a one story building, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 6000A-US. (49) modules Trina Solar TSM-250PA05.18. NO FEES FOR PERMIT PER SENATE BILL 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24868	10041-10000-15147	2500 S NAVY WAY PIER 400	90731	15	021B209   245	7440022909	M3	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Closed	11/05/2012 12:00:00 AM	ADDRESS	33.73363	-118.2408	Install new crane#2 at port of L.A., APM Terminals.  Plan check for power only.NOTE: refer to 10041-10K-15149 for crane #1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24869	17041-20002-45075	20251 W CHAPTER DR	91364	3	165B113   109	2174023034	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.15006	-118.57724	Revision to approved set of plans.  Addition of subpanel.  $0 plan check/permit fee due to State Senate Bill SB 1222.(((Plan check for solar pv system w/roof-mounted array on SFD.load side connection.11.4kW ungrounded system. (33) 305W pv modules.Each module has a 320W power optimizer.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24870	16041-10000-32684	1039 S HOBART BLVD	90006	10	129B193   532	5080017004	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			09/14/2016 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	34.05145	-118.30541	PC FOR POWER AND ENERGY. NEW APARTMENT BUILDING. TOTAL OF 28 UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24871	17041-20000-38693	21820 W BURBANK BLVD Suite 175	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.17228	-118.6032	Plan check for energy only. TI to south half of office suite 175. New lighting (incl. emergency) - 931sqft. Plan check only - permit pulled under application #17041-90000-42107.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24872	14041-10000-07241	11975 W BLUFF CREEK DR	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	33.98224	-118.40247	METHANE MITIGATION PLANS. ELECTRICAL PLANCHECK APP # 13041-10000-35622.BLDG PERMIT: 13010-10000-04245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24873	17041-10000-46360	1025 S BERENDO ST	90006	1	129B197   316	5078012004	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			12/27/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.05197	-118.29388	PC for FA system for 5 story  WITH BASEMENT GARAGE FOR 44 unit apartment building. Installing 147 devices with one fire alarm panel, 4  RPS and one annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24874	18041-10000-13115	9719 S MAIN ST	90003	8	093A203   293	6053014013	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	33.9476	-118.27403	**Zero dollars permit fee per SB 1222/ AB1414**PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 33.29 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24875	15041-20000-15653	1054 S FAIRFAX AVE	90019	10	132B177   855	5086001046	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.05661	-118.36436	Title 24 plan check only.  Total area = 2,380 sq. ft.  T.I. to existing retail space.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24876	19041-10000-37122	21001 W KITTRIDGE ST	91303	3	180B109   222	2148029035	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/09/2020 12:00:00 AM		Permit Finaled	05/12/2023 12:00:00 AM	ADDRESS	34.19128	-118.5908	NEW 6-STORY TYPE PARKING STRUCTURE WITH ROOFTOP PARKING WITH A NEW 2,000AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24877	14041-10001-18671	670 N PERUGIA WAY	90077	5	141B149   162	4362003017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			Reviewed by Supervisor	08/01/2014 12:00:00 AM	ADDRESS	34.08163	-118.45004	((((Expedite Fees))))Install roof mounted solar PV system on existing residential building.  Total system size = 17.7 kW DC.  61 modules w/ central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24878	14041-10000-21338	3811 S CLOVERDALE AVE	90008	10	117B177    90	5029006025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.01759	-118.36027	Installation of 14 solar modules with microinverters.  Total system size = 2.66 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24879	18041-20000-38165	22657 W SYLVAN ST	91367	3	177B097   100	2039022022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.18476	-118.6209	Plan check for a PV1 roof-mounted PV system. System size is 15.48 kWdc/13.76 kWac and consists of (43) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24880	19041-10000-11445	4347 W ADAMS BLVD	90018	10	123B185   673	5059003901	C2-1-O-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.02	Electrical	Electrical	Apartment			04/08/2019 12:00:00 AM	02/26/2021 12:00:00 AM		Permit Finaled	09/08/2022 12:00:00 AM	ADDRESS	34.03275	-118.33394	PC FOR NEW 4 STORY, 48 UNIT AFFORDABLE SENIOR HOUSING W/ MANAGERS UNIT PER. SCOPE INCLUDE NEW 1200A SERVICE. TOTAL AFFECTED AREA IS 21521SQ.FTB#19010-10000-01014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24881	13041-10000-34317	746 W ADAMS BLVD EGG BLDG 2	90007	9	121-5A203   2	5123017008	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.02964	-118.27978	PLAN CHECK FOR POWER. T.I. REPLACING EXISITING PANEL BOARDS WITH NEW FOR EMERGENCY AND LIFESAFETY, RECONNECTING EXISITING LOADS.  ADDING 1 ATS. LOAD DOESNT EXCEED 400 AMPS. REPLACING 200 AMP CHILLER WITH 400 AMP CHILLER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24882	17041-20001-28132	333 S BERENDO ST	90020	10	135B197   339	5502006022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	09/28/2017 12:00:00 AM	ADDRESS	34.06807	-118.29431	Expedite feePV2.  Install 20 kW roof mounted grid tied PV system.  (65) modules with (2) Fronius Primo 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24883	17041-20000-30123	4710 N NOMAD DR	91364	3	168B113   355	2175039013	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.15597	-118.56807	Plan check for the addition of (4) Tesla Powerwalls onto an existing PV1 roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24884	16041-10000-10879	11870 W SANTA MONICA BLVD 109	90025	11	126B145   478	4263033055	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.0419	-118.45979	T-24, CHANGE OF USE FROM RETAIL STORE TO TAKE OUT RESTAURANT SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1050.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24885	13041-20000-36306	4520 E HUNTINGTON DR NORTH PV2	90032	14	142-5A229 296	5305035006	RD2-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.08413	-118.19022	New Photovoltaic system for an existing commercial building.  3-Phase PV system on a 600 amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24886	15041-10000-40348	3535 E GARNET ST	90023	14	120A227   174	5191011017	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.02169	-118.20032	PV1 SFD TOTAL SYSTEM SIZE 3KW AC USING CENTRAL INVERTER WITH 9 MODULES. CONNECTED TO NEW LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24887	18041-20000-04840	2414 E MICHIGAN AVE unit 2	90033	14	127-5A223  81	5180002023	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Closed	04/26/2018 12:00:00 AM	ADDRESS	34.0449	-118.20834	PV2.  Reinstallation of 2.25kw AC pv system interconnected with msp.this is system 2 of 3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24888	17041-10000-37629	800 S FIGUEROA ST # 1120	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.04771	-118.26116	Alterations in existing office space- new branch circuits for power and lighting ficturesplan check is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24889	15041-10000-02766	2826 E 12TH ST	90023	14	120A221   189	5169009018	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.02109	-118.21845	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 1528SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24890	13041-10007-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	03/29/16Changes to an approved set of plans, Note changes on delta 34. Changes include the removal of light fixture and addition of a smoke guard door circuit. (((10/18/2015Changes to an approved set of plans. Changes are cluded on delta 28. Changes include the relocation of the inverter battery cabinet and adding block splices from MSB to RA-2. PC only.  )))(((REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  )))((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24891	19041-10000-35026	9852 N LASAINE AVE	91325	12	201B129    96	2755013034	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Issued	09/17/2019 12:00:00 AM	ADDRESS	34.24998	-118.51253	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIS-1P6K-4G-US) WITH 32 MODULES(HANWHA Q-CELLS,Q.PEAK DUO) USING RAPID SHUTDOWN EQUIPMENT CONNETED TO NEW SRVICE NEW 200A SERVICE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24892	16041-10000-37452	1107 W 185TH ST	90248	15	060B197   122	6109021012	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/17/2016 12:00:00 AM	ADDRESS	33.86282	-118.29303	PV1 roof mounted solar system installation to a singe family home. Installing 40 modules: sunpower SPR327NE-WHT-D and 2 inverters: solaredge SE7600 and 3000A-USPermit has been pulled on 16041-10000-36438	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24893	16041-10000-12935	725 S FIGUEROA ST Suite 3350	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISING HIGH RISE COMMERCIAL BUILDING ON SUITE 3350. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, TWO NEW TRANSFORMERS, AND 4 NEW PANELS. TOTAL AFFECTED AREA IS 9449 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24894	11041-20000-05126	3651 S WATT WAY	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.02013	-118.28812	Plan check power for new medium voltage service upgrade for USC Vivian Hall Engineering Building. No new loads added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24895	16041-10000-09338	6228 3/4 W MANCHESTER AVE	90045	11	096B165   563	4123003020	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	33.95959	-118.39458	T-24, PC FOR ENERGY ONLY. TI FOR LEASE SPACE #2. CHANGE OF USE FROM MEDICAL OFFICES TO  REMOTE KITCHEN AND BACK OF HOUSE OPERATION FOR RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 636 SQ. FT.NOTE: PERMIT PULLED UNDER PCIS#16041-10000-08393 / X16LA04010	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24896	17041-10000-14614	888 S FIGUEROA ST 1500-1600	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM			PC Info Complete	07/06/2017 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI TO 15TH AND 16TH FLOORS. OFFICE TI. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24897	19041-10000-07466	201 N FIGUEROA ST SUITE 300	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.05859	-118.25142	T-24 PLAN CHECK TO A TENANT IMPROVEMENT WORK IN AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW EXUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 17513 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24898	19041-10000-33523	13100 N OLIVE PL	91342	7	222B149  1165	2505005***	(Q)RD6-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.30867	-118.45288	PV 1 ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTER WITH POWER OPTIMIZERS. (21) MODULES, (21) OPTIMIZERS, (1) 5.0 INVERTER. TOTAL SYSTEM SIZE IS 5.0 KWAC / 5.985 KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24899	18041-20000-15835	20636 W CHESTNUT CIR (#329)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.2931	-118.58383	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24900	17041-10000-06514	11925 W WILSHIRE BLVD STE 101	90025	11	129B145   934	4265014095	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.04655	-118.46473	T-24, PC FOR ENERGY ONLY. CONVERT EX OFFICE TO RETAIL SPACE ON 1ST FLOOR OF AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1899 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24901	14041-20000-09241	17545 W BALTAR ST	91325	12	189B129   319	2201004026	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.21655	-118.51582	PV1.PV STANDARD PLAN SIZE 3KW TRANSFORMLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24902	16041-10000-45099	6630 S VAN NESS AVE	90047	8	102B189   435	6016015016	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	33.97833	-118.31759	PC FOR ENERGY. CHANGE OF USE FROM STORE/MARKET/DWELLING TO  CHURCH.  CONNECTED LOAD< 400A. TOTAL AREA 1105 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24903	15041-20000-01099	4202 E HATFIELD PL	90032	14	136-5A229 228	5215002009	R2-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Expired	03/22/2017 12:00:00 AM	ADDRESS	34.06664	-118.19381	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.5KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24904	10041-10000-12979	3601 S WATT WAY Room #100	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM	07/19/2010 12:00:00 AM		Permit Finaled	08/04/2010 12:00:00 AM	ADDRESS	34.02113	-118.28752	TI in an existing commercial area of the USC in Room #100 of the SEAVER SCIENCE LIBRARY building. Plan Check is for Title 24 Energy ONLY. PERMIT ALREADY PULLED FOR 20 CIRCUIT IN APPLICATION 10041-20000-12860.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24905	10041-10000-00727	354 S SPRING ST	90013	9	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Public Safety Only			01/14/2010 12:00:00 AM	01/14/2010 12:00:00 AM		Permit Finaled	03/02/2010 12:00:00 AM	ADDRESS	34.04893	-118.24796	REPLACING FIRE CONTROL PANEL WITH ONE OF THE SAME MANUFACTURER; DEVICES ARE OF THE SAME MANUFACTURER AND CAOMPATIBLE WITH THE NEW FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24906	18041-10000-03772	5621 W BOWCROFT ST	90016	10	117B173    67	5025005025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.02026	-118.36784	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 14 MOUDULES WITH 14 MICROINVERTES. SYSTEM SIZE 4.55KWDC  3.36KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24907	14041-10000-11104	18021 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.26491	-118.52556	This is a low rise existing ti,  title 24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24908	19041-10001-24389	5000 N VAN NUYS BLVD #400	91403	4	171A151   223	2248008087	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Approved	11/08/2019 12:00:00 AM	ADDRESS	34.16138	-118.44849	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS REVISIONS TO LIGHTING LAYOUT. ALL CHANGES ARE CLOUDED UNDER DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24909	16041-10000-21734	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.93576	-118.3779	NEW FA SYSTEM. 116 DEVICE AND 2 PANELS AND 1 POWER SUPPLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24910	11041-10000-03852	1947-2001 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			03/01/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Expired	11/20/2015 12:00:00 AM	ADDRESS	34.10686	-118.33085	THESE PLANS ARE AS-BUILT SET OF PLANS APPROVED UNDER APPLICATION 07041-20000-20547 .PERMIT WERE OBTAINED SEPARATELY UNDER APPLICATIONS 07041-20000-07966. FIRE ALARM PLANS WERE APPROVED UNDER 10041-10000-00239. THESE PLANS WILL BE REVIEWED ON HOURLY BASIS .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24911	16041-10000-23361	17207 W PACIFIC COAST HWY	90272	11	126B117   631	4415019012	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	10/24/2018 12:00:00 AM		Issued	10/24/2018 12:00:00 AM	PIN	34.03972402	-118.55383604	PC FOR POWER. REPLACING ONE GENERATOR SIZE 350 KW , 600A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24912	16041-30000-31132	5300 S CENTRAL AVE	90011	9	108B209   358	5104014032	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	33.99464	-118.25626	Plan check Title 24 only in existing space T.I., remove outdoor HID lighting fixtures and replace with new LEd lighting fixtures. Total area: 3,145 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24913	18041-10004-35822	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	DELTA 5 CHANGES TO APPROVED SET OF PLANS- NEW FEEDER TO TEMPORARILY SUPPLY HVAC UNITS HAVING ONLY THE FAN MOTORS TO FUNCTION-OTHER LOADS HER LOCKED OUT(((((((DESIGN BUILD. Full plan check for a office/warehouse TI. Scope include new lighting, and equipment with a total area of 312,000-SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24914	16041-10000-42172	13914 N EMIR AVE	91342	7	228B153    30	2582012011	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.32552	-118.43316	Intalling one solar panel to existing solar system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24915	10041-10000-25470	600 S SAMPSON WAY	90731	15	015B201    20	7440026***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	33.7387	-118.27907	Installation of new floating ducks with dredging for the Port of LA. EPC is for power.last and final extention was approved until 12/23/13 in Van Nuys by elie maalouf variance approved on 11/5/13	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24916	18041-10000-22000	2052 S CENTURY PARK EAST	90067	5	132B161    31	4319001013	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.05916	-118.41227	INSTALL TWO CHILLERS AT 480V, 1,200 AMPS, One 1.5MVA, 4,160V:480V X-Former, and other loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24917	17041-10000-28377	7246 N TOPANGA CANYON BLVD	91303	3	186B101   946	2111022020	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.20239	-118.60574	REMOVE HID  FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY.Total affected 22125 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24918	19041-20000-40775	10911 W CHALON ROAD	90077	5	141B149    68	4369028001	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	34.08453	-118.45569	POWER PLAN CHECK FOR INSTALLATION OF A 243 KWH ENERGY STORAGE SYSTEM ON EXISTING SFD WITH EXISTING PV. SCOPE OF WORK CONSISTS OF (18) NEW 13.5 KWH TESLA BATTERIES, (2) 400A BACKUP LOAD CENTERS, (2) 200A COMBINER PANELS, AND A 225A BACKUP LOAD PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24919	19041-10000-34127	711 N NORTH MAIN ST	90012	1	180B169  1236	2335027013	C2-2	Central	Central City North	Historic Cultural North		2071.02	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	34.05862	-118.23772	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24920	17041-20001-30131	17031 W GUNTHER ST	91344	12	213B133   130	2607002033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.28343	-118.50347	Expedite fee.(((PV1.  Install 3.0 kW roof mounted grid tied PV system.  (11) modules with (1) SolarEdge 3kW rated string inverter.  3.0 kW system is being added to an (E) PV system.  Install 13.5 kWh rated energy storage system with automatic load control relay.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24921	16041-10000-04783	3327 E PEPPER AVE	90065	1	145-5A219 383	5453020003	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.09126	-118.22247	PV1, rooftop solar installation 3kW AC(12) KU2656ZPA(1) SOLAREDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24922	13041-10001-22253	2138 W BAXTER ST	90039	13	145-5A209 323	5422021012	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.09184	-118.25624	EXPEDITE PLAN CHECK PER APPLICANTS REQUEST..PV1. 2 STORY HOUSE. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 12.25KW. TRANSFORMELESS INVERTER. 50 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24923	19041-10001-28758	7712 N MILWOOD AVE	91304	3	189B105   617	2109027008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.21038	-118.59463	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3.8KWac, SCOPE OF WORK INCLUDES 10 MODULES (MISSION SOLAR MSE310SQ8T) WITH OPTIMZERS (SE P320) AND A CENTRAL INVERTER (SE3800H-US). ADDITION TO AN EXISTING 5KWac SYSTEM. PANEL UPGRADE PULLED SEPARETLY. TOTAL COMBINED SYSTEM SIZE IS 8.8KWac. NOTE PARTIAL PERMIT FEES HAVE BEEN PAYED UNDER 19041-90000-28758	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24924	12041-20000-26803	4815 N QUEDO PL PV 1	91364	3	169-5A109 105	2166046008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	34.15844	-118.58603	PV-1. Plan check for single family dwelling. 12.96kW.PERMIT HAS ALREADY BEEN PULLED UNDER: 12041-20000-22366. ZONING HAS ALSO BEEN DONE ON PERMIT.INSTALL ROOF MOUNTED PV SOLAR SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24925	17041-10000-17164	1809 N BARRANCA ST	90031	1	139-5A219 112	5447017004	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.07497	-118.22411	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 68,800 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24926	12041-10000-30143	1815 S SOTO ST	90023	14	117A219    92	5169029017	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.01602	-118.22017	TI on a commercial office Bldg. EPC is for power & energy. (single story Bldg).  Variance is submitted to seperate the fire alarm from the power.  12 month utility bill is submitted for demand calculations	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24927	18041-10000-08870	7108 N SEPULVEDA BLVD	91405	6	183B145    83	2220022***	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.19959	-118.466	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING LIGHTS IN A COMMERCIAL BANK. TOTAL AFFECTED AREA IS 5593 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24928	19041-10000-44554	852 N LA BREA AVE	90038	5	144B181   886	5525005001	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	34.08685	-118.34386	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24929	13041-10000-28277	14006 W RIVERSIDE DR #227	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	TITLE 24, PLAN CHECK ONLY. SCOPE OF WORK IS < 400A. TENANT IMPRPOVEMENT FOR A RETAIL STORE IN FASHION SQUARE MALL. TOTAL AREA TO BE 3802 SF. ELECTRICAL PERMIT TO BE PULLED @ THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24930	17041-20001-44441	9376 W READCREST DR	90210	4	147B165   564	4352012019	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2017 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.09564	-118.40394	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.7.6kW ungrounded system. (29) 360W pv modules. (29) 370W power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24931	18041-10000-05285	10250 W SANTA MONICA BLVD #2455	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant ""Skin x Five"" suite 2455 in Westfield Century City. Install (2) new panels, and (1) 30 kVA xfrm. New lights and powers. Total area: 872 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24932	15041-10000-41222	5926 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.10524	-118.18409	TI. NEW DAY CARE FACILITY. NEW LIGHTING. PC FOR T24 ENERGY ONLY.*Investigation Fee paid under building permit# 15016-10000-04004	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24933	19041-10000-06185	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	33.98076	-118.40716	Full Plan check, Facebook TI in 5 story bldg. Scope of work includes new panels, circuits and lighitng. Total sq. ft. 118,519. (Fee Estimate)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24934	14041-10000-11437	5726 W COLOGNE ST	90016	10	126B173   948	5064028002	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Expired	07/12/2016 12:00:00 AM	ADDRESS	34.03853	-118.36775	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC WITH OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24935	10041-20000-02596	15760 W VENTURA BLVD #1125	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	02/16/2010 12:00:00 AM		Permit Finaled	03/23/2010 12:00:00 AM	ADDRESS	34.1552	-118.47684	office t.i.Energy, EmergencyFire Life safety by others 10041-10000-02022	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24936	19041-20000-34471	10987 W BLUFFSIDE DR	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	09/14/2021 12:00:00 AM	ADDRESS	34.14185	-118.36953	PV2 BUILDING #4 (N) 20.4 KW AC/22.68 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (63) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24937	11041-20000-19753	127 S SAN VICENTE BLVD Bulletin-94TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta # 94TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24938	14041-10000-26338	538 N ALBRO ST	90732	15	018B193    31	7446011003	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	33.74849	-118.30193	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 4.2 KW.(23) KYOCERA # KD255GX(1) ABB PVI 5000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24939	16041-10000-12476	15201 W SUNSET BLVD	90272	11	129B129   809	4423016073	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.04639	-118.52437	"T-24, PC FOR ENERGY ONLY. TI FOR AN EXISITNG COMMERCIAL BUILDING (""CHIPOTLE"" RESTAURANT). SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND TWO NEW PANELS. TOTAL AFFECTED AREA IS 1599 SQ. FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24940	15041-20000-38566	8607 N BOTHWELL ROAD	91324	12	192B117    34	2783013015	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.22658	-118.56131	PV1.  Install 10.07 kW roof-mounted, utility-interactive PV system - (38) Kyocera KU2656ZPA modules and (2) ABB PVI-3.6 transformerless inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24941	18041-10000-48273	1250 S WESTMORELAND AVE	90006	1	129B197   979	5076018023	R4-1XL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Issued	02/04/2019 12:00:00 AM	ADDRESS	34.0479	-118.2889	PLAN CHECK FOR FIRE ALARM SYSTEM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 420 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24942	17041-30000-09000	22730 W RODAX ST	91304	12	192B097   146	2004014016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.22367	-118.6227	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (36) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24943	14041-10002-07985	380 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	PIN	33.94386821	-118.41794839	(((6/13/2014- PLAN CHECK ONLY. PROVIDED NOTES AND SOME CHANGES TO EMERGENCY LIGHTING.)))plan check only. changes to approved set of plans: changed some lights to emergency being fed by generator.old description: TENANT IMPROVEMENT AT THE TBITEC OFFICES/CONFERENCE ROOMS; TERMINAL CONFERENCE OFFICES AND ANA AND PACIFIC AVIATION LEVEL 5 NORTHPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24944	16041-30000-04539	1842 N CHEROKEE AVE	90028	13	150A185   300	5547004019	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.1044	-118.33463	Installation of new fire alarm central station monitoring system in existing 5 story 58 unit apartment building.  1 New fire alarm panel with 3 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24945	14041-10000-00018	1145 S TOWNE AVE STE #8	90021	14	123A211    25	5132010047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.03301	-118.2507	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 390 SQ FT. REPLACING TOTAL OF 2 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24946	15041-20000-09002	17616 W BLYTHE ST	91325	12	189B129   602	2201032003	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.21483	-118.51723	Installation of new roof mounted solar PV arra.  Total system size = 6.8 kWac.  Two inverter system with 4 strings and 33 total modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
24947	19041-10000-14157	6340 W DREXEL AVE	90048	5	135B177   148	5510009026	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.06863	-118.36588	[e-plan] REVISION TO EXISTING PERMIT #19041-10002-01689; RE-FEED NEW GENERAC PANEL WITH TRANSFER SWITCH FROM MAIN PANEL WITH 25A CIRCUIT BREAKER AND INVERTER ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24948	13041-10002-01477	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.03393	-118.22985	changes to approved plans: plan check request by inspector for change/reduction in lights 10001:Revisions to permitted set of plans: change the outlay of the bar to a rectangular shape; removed freight elevator ; reduced lighting density; rearrange circuits(((((((First time tenant for a restaurant space.  Power and energy.PLACE OF ASSEMBLY. OCCUPANT LOAD: 220+	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24949	14041-10000-12397	1200 S CLUB VIEW DR 16th north	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.06748	-118.42481	Title 24 for 16th north corridoor emergency lighting and  exit sign.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24950	10041-10001-25799	3310 S CENTRAL AVE	90011	9	117A209   419	5114026***	(T)(Q)C2-1L	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM			PC Approved	06/03/2011 12:00:00 AM	ADDRESS	34.01319	-118.25635	Revision to the approved plan. EPC is for Delta 1. (((((((((((((((TI for a coffee shop, no cooking. EPC is for Energy & T24.))))))))))))))0000000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24951	09041-20006-15447	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM			Corrections Issued	03/14/2011 12:00:00 AM	ADDRESS	34.27548	-118.56626	Changes from previously approval.  All changes on the plans indicated by DELTA 7.  Note: Previously approval plans will be submitted for reference by the applicant.*****Walmart remodel - interior gut and installation of new service gear, panels, ckts, equipment, and lighting.  P/C is for Power and Energy.  Variance for Fire Alarm Separation may need to be filed.  FINALS FEES SHOULD BE VERIFIED PRIOR TO PERMIT ISSUANCE.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24952	16041-10000-27482	3000 S ROBERTSON BLVD	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	T-24, PC FOR ENERGY ONLY. INTERIOR AND EXTERIOR RENOVATION OF AN EXISTING OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS FOR INTERIOR LOBBY AND NEW LIGHTS FOR EXTERIOR HARDSCAPE. TOTAL AFFECTED AREA IS 12390 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24953	17041-20000-17594	20455 W DEVONSHIRE ST	91311	12	204B109   153	2707014001	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM			PC Info Complete	09/11/2017 12:00:00 AM	ADDRESS	34.25742	-118.57921	PLANCHECK FOR POWER AND ENERGY.  PROPOSED FUEL CANOPY/ 2 DISPENSERS & RESTRIPE PKG LOT. HAZARDOUS LOCATION.building p # 17010-20000-00776	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24954	14041-10000-24767	921 S CROCKER ST #C18; C19;-C20	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.03582	-118.24984	First tenant in renovated buildingcore and shell permitted 13041-10000-22477	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24955	19041-10000-43758	680 N NORTH SPRING ST	90012	1	133-5A215 203	5408013023	C2-2	Central	Central City North	Historic Cultural North		2071.02	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM	09/14/2020 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.05936	-118.23795	SERVICE UPGRADE TO 600AMP,  120/240V 3 Phase 4 WIRE SERVICE/DISTRIBUTION BOARD FEEDING EXISTING COMMERCIAL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24956	11041-10000-00447	5200 W WILSHIRE BLVD	90036	4	132B181    30	5507024010	[T][Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.06194	-118.3435	New methane gas control system with modification.  Electrical Plan Check for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24957	12041-10000-16645	13426 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15935	-118.42548	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #8	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24958	12041-10001-19990	546 N OXFORD AVE 1-25	90004	13	141B193  1005	5521013004	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			08/14/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	34.08121	-118.30785	CHANGES TO AN APPORVED SET, NOTE CHANGES ON DELTA C. SCOPE OF WORK INCLUDES CHANGE TO LED LIGHTING IN COMMON AREA AND OUTDOOR. (((PLAN CHECK POWER ANS ENERGY FOR NEW 25-UNIT APARTMENT BLDG; 2-STORY BLDG. WITH BASEMENT PARKING GARAGE. 1200A SERVICE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24959	11041-20000-04166	2740 E OLYMPIC BLVD	90023	14	120A221    67	5170027006	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.02352	-118.21855	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24960	14041-10000-03686	400 S WESTERN AVE #203	90020	10	135B193   459	5503014023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.067	-118.30888	COMMERCIAL TI AND CHANGE OF USE portion  of  building FROM COMMERCIAL RETAIL TO MEDICAL CLINIC . 1040  sq   feet   on  the   second  floor    space D ,PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24961	18041-10000-06774	17922 W MAYERLING ST	91344	12	216B129   304	2601018034	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.28675	-118.52298	PC FOR ROOFMOUNTED PV SYSTEM. SCOPE INCLUDES 30 MODULES(LG335N1C-A5) WITH OPTIMIZERS(SOLAR EDGE P400) , LOAD CENTER AND TWO CENTRAL INVERTERS(SOLAR EDGE SE 5000A-US). SYSTEM SIZE IS 10KWac AND 10.05KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24962	16041-30000-11823	6801 S PARK TER #545	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	33.97698	-118.39328	Title 24 plan check only.  Total area = 1,340 sq. ft.T.I. to existing commercial low rise office space.  Subpanels to remain existing.  New lighting and receptacles.       Building permit #16016-30000-07460	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24963	18041-20000-16804	725 S FIGUEROA ST 6th Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	Tenant improvement of (E) commercial highrise office space.  Plan check for energy - 19,475 sq ftBuilding permit filed under 18016-10000-12506.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24964	18041-10000-41026	3787 S VERMONT AVE	90007	8	117B197   514	5037018009	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.01746	-118.29176	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
24965	17041-10001-42176	1346 W 58TH ST	90037	9	108B197  1359	5002015001	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			Corrections Issued	11/29/2017 12:00:00 AM	ADDRESS	33.98977	-118.29964	EXPEDITE PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH A TESLA POWERWALL. TOTAL SYSTEM SIZE IS 3.6KWac.(17)MODULES-TRINA SOLAR #TSM-300DD05A.18(1)5.8KVA 1.5KWH AC POWERWALL(1)INVERTER-PVI-3.6-OUTD-S-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24966	10041-20000-17300	14006 W RIVERSIDE DR #FC3	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	12/22/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	energy plan check sorabol at fashion square	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24967	15041-20000-02444	1832 S WILTON PL	90019	10	126B189   770	5073018007	[Q]R3-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Apartment			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.04076	-118.31428	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 15 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24968	15041-10000-05363	6500 W WILSHIRE BLVD SUITE 1260	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.06371	-118.3703	TI TO AN EXISTING HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING CIRCUITS AND PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN SUITE 1260.  TOTAL SQUARE FOOTAGE 3200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24969	12041-10000-13136	8500 W BEVERLY BLVD #602	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT IN A RETAIL STOREPLAN CHK IS FOR TITLE 24.(plan check only, permit pulled under# 12041-20000-16339)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24970	11041-10000-15100	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Expired	10/31/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	Parking garage T-24 plan check.  Replacing light fixtures for 2-story parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24971	10041-10000-09891	5050 N SEPULVEDA BLVD	91403	2	171A145   125	2263009024	R4-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.16224	-118.46592	Install a new 56KW (Total) PV system on an apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24972	19041-20000-47893	22480 W CASS AVE	91364	3	171B101   785	2075009032	RE9-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.16386	-118.61695	PV1.  Install 15.75 kW DC roof mounted grid tied PV system.  (44) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24973	14041-10001-17388	3183 W WILSHIRE BLVD	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.06196	-118.29111	Changes to approved set.  Changes to original lighting plan.*****Previous Work Description*****TI to (E) bakery/restaurant space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24974	19041-10000-18611	3566 S WESTERN AVE	90018	8	120B193  1125	5041012050	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.02325	-118.30873	remove outdoor hid fixtures and replace with new led fixtures t24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24975	17041-20001-26114	19931 W MID PINES LANE	91326	12	213B113    17	2701034014	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	ADDRESS	34.28413	-118.57005	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (2) inverters, (47) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24976	18041-10001-07828	1501 W SUNSET BLVD A;B;APTS	90026	13	139-5A209 235	5419027007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	08/08/2022 12:00:00 AM	ADDRESS	34.07605	-118.2552	Change to approved set by updating the fault current, AIC bracing and modifying the single line and floor plan. All changes under delta-R4, R5, R6, and delta-3 only. This project is located in the same plan with other 2 projects ( 18041-10001-07818 and 07823).(((REMODEL AND CHANGE OF USE FROM 2-STORIES  OFFICE WITH ATTACHED GARAGE TO RESTAURANTS ON THE 1ST FLOOR AND 5-UNITS APARTMENTS ON THE 2ND FLOOR.FEE FOR SMOKE DETECTORS WERE NOT INCLUDED)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24977	18041-10000-05293	15200 W SUNSET BLVD #105	90272	11	129B125   727	4412002023	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.04624	-118.52472	PC for T24 for new lighting in restuarant. Installing new lights, receptacles and equipment. B# 17016-10000-33183.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24978	19041-10001-10325	2410 N LILLYVALE AVE	90032	14	139-5A237 104	5220034025	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.07504	-118.16432	CHANGES TO APPROVED SET ALL CHANGES UNDER DELTA 2, SCOPE OF WORK INCLUDES ADDING 90 MINUTE BATTERY BACKUP TO FIXTURES (PER INSPECTORS REQUEST), AND CHANGES TO EQUIPMENT, LOAD RELOCATED.PERMIT HAS BEEN ISSUED UNDER 19041-10000-10325	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24979	18041-30000-37567	5670 W WILSHIRE BLVD Parking	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for T24 only,  replacing rooftop garage light fixtures on an existing commercial building.  Power will be fed from existing circuits. Total area: 56,275 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24980	17041-10000-14711	800 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	33.94305	-118.39757	Plan check for Title 24 only in existing space office area T.I. Total area: 12,429 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24981	18041-20000-21404	7911 W OCEANUS DR	90046	4	153B173   884	5569007037	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM			Corrections Issued	06/25/2018 12:00:00 AM	ADDRESS	34.11222	-118.36667	Plan check for PV roof mounted system, System size: 8.0kWac with 36 modules and 1 inverter(8.0kw) connected to 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24982	16041-10001-44906	910 S BROADWAY 2nd Floor	90015	14	127-5A209 260	5139002017	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/09/2017 12:00:00 AM	ADDRESS	34.04197	-118.25618	Supplemental PC for approved set. Changes in lighting fixtures. Total area is 2770 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24983	10041-20001-18260	6250 W HOLLYWOOD BLVD #500	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.10133	-118.32547	PLAN CHECK TO REVISION TO APPROVED PLANS. REVISION DELTA 3 TO ADD A NEW 480V INSTANT WATER HEATER AND INCREASE SIZE OF 208V WATER HEATER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24984	11041-20000-06739	10250 W SANTA MONICA BLVD FC-14	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	07/01/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to existing space (Juicy Bird).  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24985	12041-10000-02246	1149 S BROADWAY 8TH FLR.	90015	14	126A209   600	5139019900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM			PC Approved	01/31/2012 12:00:00 AM	ADDRESS	34.03859	-118.26015	INTERIOR ALTERATION:  REMOVE NON-BEARING PARTITION WALLS ON 8TH FL.  PUBLIC WORKS BLDG.PLAN CHK IS FOR TITLE 24 ONLY-CREATE CONFERENCE ROOM IN OPEN OFFICE SPACE AND REMODEL NEARBY OPEN OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24986	17041-20000-31154	6330 N LAUREL CANYON BLVD	91606	2	180B165   800	2334003031	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			Corrections Issued	08/30/2017 12:00:00 AM	ADDRESS	34.18575	-118.39631	Change of use from retail to adult daycare center and office.  Title 24 plan check.   plancheck and permit under supplemental : 17041-20001-31154	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24987	15041-10000-20410	6540 W HOLLYWOOD BLVD	90028	13	148-5A187 184	5547016005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM			PC Info Complete	07/28/2015 12:00:00 AM	ADDRESS	34.10142	-118.33231	Plan check for energy only. TENANT IMPROVEMENT IN (E) RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24988	14041-10000-13649	412 S ORANGE DR	90036	4	135B181   417	5507011024	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.06649	-118.34172	PV1 7.67KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE7600A-US}]. [(26)modules: {LG ELECTRONICS, LG-295N1C-A3}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24989	16041-20000-13563	17051 W PARTHENIA ST	91325	12	195B133   431	2690010005	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.22865	-118.50434	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.28 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24990	11041-10000-25012	22286 W YBARRA ROAD	91364	3	168B101   940	2076021022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	ADDRESS	34.15344	-118.61198	Plan check 8.9KW roof mounted photovoltaic system single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24991	17041-10000-05823	1500 W 6TH ST	90017	1	132A205   142	5142028020	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Refund in Progress	08/22/2017 12:00:00 AM	ADDRESS	34.05643	-118.26833	PC for outdoor title 24. Removing HID fixtures and replacing them with new LED ones. Area: 13,000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24992	14041-10000-12132	933 S FRESNO ST	90023	14	121-5A225   9	5189002034	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Expired	05/31/2016 12:00:00 AM	ADDRESS	34.02903	-118.20628	PV1 2.805KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(11)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24993	19041-20000-05403	806 W ADAMS BLVD	90007	9	123A201   233	5123003022	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM			Verifications in Progress	05/09/2019 12:00:00 AM	ADDRESS	34.02974	-118.28024	new six-story 99-unit apartment building 4000 amps service.  plan check for power and energy.NOTE: SEE COMMENTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24994	15041-10000-02039	2153 W VALLECITO DR	90732	15	012B189   296	7562023011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	33.72759	-118.32224	PV1 3.24KW roof-mounted system with (15) LG Electronic LG275S1C - B3 modules and Enphase M215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24995	11041-20000-12815	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			Corrections Issued	06/26/2011 12:00:00 AM	ADDRESS	34.01173	-118.28296	Project is taking place at the Coliseum.  Adding new subpanels and new loads.  Regular plan check.NOTE TO PLAN CHECKER:  Scope of work was not clear on plan and applicant was not familiar with the electrical aspect of the job.  Fees include only the sub-panels and the circuits within those sub-panels per contractor.  Please verify fee during plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
24996	16041-10003-15022	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	11/18/16PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA DCN-012 AND CLOUDED ON PLANS. CHANGES INCLUDE RELOCATING IT ROOM 241.  UPDATED LENGTH OF FEEDER ON SINGLE LINE DIAGRAM.  ADDITION OF ONE NEW LIGHT.  PHOTOMETRICS AND TITLE 24 UPDATED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24997	18041-10001-26010	655 S HOPE ST #LM101	90017	14	129A209   262	5144006901	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM			PC Approved	10/18/2018 12:00:00 AM	ADDRESS	34.04849	-118.25759	CHANGES TO APPROVED SET PER INSPECTORS REQUEST. HIGHRISE. PLANCHECK ONLY. REVISE EMERGENCY LIGHTING WIRING TO CONNECT TO EXISTING GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
24998	14041-20000-10840	20411 W CELTIC ST	91311	12	210B113    61	2707030009	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	07/12/2014 12:00:00 AM	ADDRESS	34.2714	-118.57717	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6.48KW AC USING MICROINVERTER SYSTEM ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
24999	11041-10000-15867	7510 W 83RD ST	90293	11	096B157   374	4114026013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	09/09/2011 12:00:00 AM	ADDRESS	33.96122	-118.4287	NEW 7KVA, ROOFTOP, PV SYSTEM FOR SINGLE FAMILY RESIDENCE.  VARIANCE FOR MICROINVERTERS IS FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25000	18041-10000-14220	1626 S TRINITY ST	90015	14	123A209   326	5127002018	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	07/20/2023 12:00:00 AM	ADDRESS	34.02996	-118.25785	PLAN CHECK FOR INSTALLATION OF A NEW OPTIONAL 200KW GENERATOR, AND TRANSFER SWITCH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25001	16041-20000-45429	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for energy only.  TI to lobby space of high rise building.  New lighting (incl. emergency) 9,260 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25002	16041-10000-26955	1428 S MAPLE AVE	90015	14	123A209    58	5133022004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.03267	-118.25857	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (INDOOR)2165 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25003	17041-10000-15753	10576 W TROON AVE	90064	5	126B161   681	4318019007	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.03763	-118.41615	PV INSTALLATION OF A NEW 6KW AC/ KW DC SOLAR SYSTEM ON A SINGLE FAMILY HOUSE(17) MODULES: HANWHA Q PEAK-G4.1305(1) INVERTER: SOLAREDGE SE6000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25004	17041-10000-09766	9363 N SYLMAR AVE	91402	6	198B149   200	2644029900	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.24059	-118.44733	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 21885 SQ. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25005	11041-10000-15618	8875 N TAMPA AVE	91324	12	195B117    48	2783025082	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01, 1134.01	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.23184	-118.55382	NEW FIRE ALARM SYSTEM FOR EXISTING RESTAURANT (CHICK FIL-A).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25006	19041-10000-43317	10759 W AYRES AVE	90064	5	126B157   760	4255028008	C2-1VL, PB-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/09/2020 12:00:00 AM		Permit Finaled	12/22/2021 12:00:00 AM	ADDRESS	34.03982	-118.42567	FULL POWER & ENERGY PC. SCOPE OF WORK INLCUDES A NEW 1600A SWITCHBOARD THAT FEEDS TWO ELEVATORS AND A NEW 1600A DISTRIBUTION BOARD  WHICH FEEDS 4 NEW SUBPANELS. THIS SYSTEM IS CONNECTED TO AN EXISITNG SERVICE. **********PLAN CHECKER TO VERIFY THE FEES.*****************************PER BUILDING(( B#19010-10000-04373NEW TYPE IB, 5 TIER  PARKING STRUCTURE ( 4 STORES WITH ONE BASEMENT)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25007	14041-20000-09398	5217 W HOLLYWOOD BLVD	90027	13	148-5A195  53	5544010025	[Q]C2-2D	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	34.10188	-118.30421	Remodel of basement, common areas, and ground floor retail of existing 7-story lowrise apartment building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25008	14041-10001-04466	2723 W 8TH ST	90005	1	132A201    11	5077020802	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Approved	02/23/2015 12:00:00 AM	ADDRESS	34.05787	-118.28484	Changes to an approved set of plans. All changes have been clouded as Delta 7. Changes include the removal of (1) panel and the addition of (2) panels. There have been changes to loads and load calculations. Lighting has not been changed. Affected sheets: E0.3, E0.4, E0.5, E2.1, E2.3, E2.31, E2.5, E2.6(((CHANGE OF USE; EXISTING 2-STORY RETAIL OVER PARKING TO CHARTER SCHOOL.BUILDING PERMIT 14016-10000-02954)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25009	19041-20000-40263	23416 W KITTRIDGE ST	91307	12	180B093   381	2036020003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.19059	-118.6371	PV1. INSTALL 11.34 KW DC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25010	19041-10000-07173	1522 N CASSIL PL	90028	13	147A185    34	5547018031	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	03/18/2020 12:00:00 AM		Permit Finaled	07/13/2023 12:00:00 AM	ADDRESS	34.0987	-118.33367	FULL PLAN CHECK FOR TWO NEW SERVICES  'MSB' 120V/208V, 4000AMP AND 'MSC' 208V/120V, 800AMP. MSB IS FEEDING THE BLDG AND MSC IS FEEDING EV CHARGERS.  NEW CIRCUITS, PANELS, TRANSFORMERS, LIGHTING  AND EMERGENCY INVERTER. TOTAL SQ. FT. INDOOR AND OUTDOOR 130,627.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25011	19041-20001-48662	3527 N WONDER VIEW DR	90068	4	159B185    49	5577004012	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM			PC Approved	12/16/2019 12:00:00 AM	ADDRESS	34.13239	-118.33748	Expedited per applicant request.PV1. INSTALL 19.09 KW DC PV SYSTEM WITH (46) MODULES AND (2) NEW TESLA POWERWALL CONNECTED TO (E) 400 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25012	15041-20000-32041	3713 N GOODLAND AVE	91604	2	162B161   649	2384011010	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.13825	-118.40766	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25013	11041-10000-19123	15034 W MAGNOLIA BLVD	91403	2	171A147    23	2263004011	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00, 1289.10	Electrical	Electrical	Apartment			09/08/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	06/06/2012 12:00:00 AM	ADDRESS	34.16455	-118.46081	Elevator recall system , one panel and 11 devices. in two story apartment bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25014	18041-10001-13596	4544 W MELBOURNE AVE	90027	4	150B197  1173	5590022003	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.10348	-118.28904	EXPEDITE PER APPLICANT REQUEST -----------------------------------------------------------------------------------------NEW ROOFTOP SOLAR SYSTEM ON TWO INTERCONNECTED SINGLE FAMILY DWELLING UINITS ( 1 AND 1/2). (1 OF 2) CONSIST OF  23 MODULES ( EAGLE MP 60B- 285W), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS 320) WITH A CENTRAL INVERTER (SOLAR EDGE SE 5000H-US).  SYSTEM SIZE IS  6.6 KWdc AND 5 KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25015	13041-20000-22205	10201 N DEMPSEY AVE PV1	91343	12	210B141   334	2666028005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North, North Hills West		1092.00, 1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.25573	-118.47733	INSTALL ROOF MOUNTED PHOTO VOLTAIC SYTEM 6.0 KW.  PLAN CHECK ONLY, PERMIT WAS PREVIOUSLY PULLED ON A SEPARATE APPLICATION.  UNGROUNDED SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25016	15041-20000-09179	11321 W TIARA ST 1-8	91601	2	177B173  1249	2337010018	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.1786	-118.37753	Plan check for PV1 roof top mounted microinverter system 18 microinverter and 18 modules with 4.05kW system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25017	13041-10000-12531	111 E UNIVERSAL HOLLYWOOD DR 6TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVEMENT ON THE 6TH FLOOR OF AN OFFICE HIGH RISE BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25018	16041-20000-22985	5612 W LEXINGTON AVE	90038	13	144B193   442	5536007004	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			06/30/2016 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	03/08/2023 12:00:00 AM	ADDRESS	34.09267	-118.31136	PLANCHECK FOR POWER AND ENERGY.  4 STORY 9 UNIT APARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25019	19041-20002-12253	6935 N MURIETTA AVE	91405	2	183B153   764	2216013005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.19671	-118.43901	changes to an approved set of plans.  changes to add combiner to consolidate (2) ESS.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25020	16041-20000-21815	20264 W JUBILEE WAY	91326	12	216B113     1	2701002076		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.28329	-118.57554	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25021	17041-10000-17167	3000 S BROADWAY	90007	9	120A205   260	5122004021	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Closed	07/13/2017 12:00:00 AM	ADDRESS	34.02204	-118.27161	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 20,000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25022	11041-10000-23059	11315 S FIGUEROA ST	90044	15	087A201   235	6075026029	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	03/19/2012 12:00:00 AM	PIN	33.93143118	-118.28297189	Ti, for a retail space , title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25023	15041-10000-19214	4101 S REDWOOD AVE BLDG A	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			Reviewed by Supervisor	06/30/2015 12:00:00 AM	ADDRESS	33.99086	-118.44043	SERVICE UPGRADE TO 1200 AMP TO BUILDING A AND SUBFEED BUILDING B UNDER SEPARATE PERMIT.  RECONNECT TO EXISTING PANELS AND BRANCH CIRCUITS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25024	14041-10002-32994	200 WORLD WAY DUTY FREE-SHOP	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	((7/14/2015))CHANGES TO AN APPROVED SET OF PLANS.  ADDING CURRENT LIMITER PANELS WITH CONTROLLERS AND REVISING LIGHTING FIXTURES.  REVISED ENERGY CALCS .  CHANGES NOTED DELTA 2 ON THE FLOOR PLAN.  TENANT IMPROVEMANT ON EXISTING SHELL SPACES 237 & 222 FOR DUTY FREE STORES.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25025	18041-10002-02341	1125 N NAPOLI DR	90272	11	129B133   263	4408004016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM			Corrections Issued	02/22/2018 12:00:00 AM	ADDRESS	34.04828	-118.50432	Fees for Tesla Storage systemPV1, New roof mounted solar system in a SFD with an energy storage system. (2) Inverters, 7.6KWAC and 5.2KWAC, (39) module, (1) load center, (3) AC Tesla Batteries.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25026	18041-10000-17853	1045 E 32ND ST	90011	9	117A209   159	5114022025	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.01495	-118.25707	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25027	16041-10000-02396	627 E 24TH ST	90011	9	120A207   113	5127008010	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Expired	02/28/2018 12:00:00 AM	ADDRESS	34.0239	-118.26146	PV1, INSTALL 5.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FASMILY ONE-STORY HOUSE.(18) MODULES: HYUNDAI HIS-S280RG(1) INVERTER: FRONIUS PRIMO 5.01-1 240	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25028	14041-10000-33355	777 S FIGUEROA ST Suite 2550	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only. Project space is a single suite (Suite 2550) on the 25th floor of a high rise building. Total lighting area = 1,021 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25029	19041-10000-48176	7753 N ETHEL AVE	91605	2	189B161   932	2303014076	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.21152	-118.41731	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 25  (SUNSPARK SST-300M) MODULES, 25  (SOLAREDGE P320) OPTIMIZERS, 1 (SE7600H-US) CENTRAL INVERTER, CONNECTED TO AN EXISTING 400A SERVICE. SYSTEM SIZE IS 7.50KW DC & 7.60KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25030	11041-20000-25678	21271 W BURBANK BLVD Ste 401	91367	3	174B105    74	2149019002	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM			Corrections Issued	12/02/2011 12:00:00 AM	ADDRESS	34.17497	-118.59473	T.I. Remodel of light fixtures in Ste 401.  Relocating the existing lights and adding motion sensors.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25031	11041-10000-01754	5211 S HOOVER ST 1 OF 3	90037	9	108B197   156	5001003002	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Apartment			01/28/2011 12:00:00 AM			Corrections Issued	02/06/2011 12:00:00 AM	ADDRESS	33.99495	-118.28727	SERVICE UPGRADE TO 600 AMP FOR EXISTING 3 SEPARATE  APARTMENT BUILDINGS AND INSTALL A SUBPANEL AND CIRCUITS IN EACH UNIT.   (APP 1 OF 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25032	11041-10000-24571	9600-9636 W PICO BLVD # 505	90035	5	132A167   258	4306001037	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM			Corrections Issued	11/16/2011 12:00:00 AM	ADDRESS	34.05501	-118.39777	CHANGE OF USE FROM RETAIL TO AFTER SCHOOL PROGRAM FOR EDUCATIONAL PURPOSES (SYLVAN LEARNING CENTER ); DIVIDE  ONE SUITE INTO TWO  SEPARATE TENANT SPACESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25033	17041-10000-22625	4547 N GRIFFIN AVE	90031	1	145-5A225  27	5303004025	[Q]RD3-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.0948	-118.20226	PC FOR PV ROOF MOUNTED ADDING NEW 4 AC MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25034	18041-10000-26661	9901 N LURLINE AVE CLUB-HOUSE	91311	12	201B109    59	2741002006	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Apartment			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.25058	-118.58431	PC FOR ENERGY ONLY, TENANT IMPROVEMENT OF COMMUNITY CLUBHOUSE. SCOPE OF WORK INCLUDES NEW CIRCUITS FOR LIGHTING AND RECEPTCLES. TOTAL SQ. FT. 1630.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25035	10041-10000-08339	5101 W JEFFERSON BLVD	90016	10	120B177   707	5049032042	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	09/01/2010 12:00:00 AM	ADDRESS	34.02566	-118.35507	TI IN AN EXISTING RESTAURANT. PLAN CHECK FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25036	18041-10000-32221	1411 E NEWTON ST	90021	14	121-5A213 230	5130010038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.02618	-118.24419	FULL PLAN CHECK FOR - CHANGE OF USE and OCCUPANCY OF [38' X 131', ONE STORY] WAREHOUSE BLDG TO CAFE/ART GALLERY W/ LIVE ENTERTAINMENT.  ADD [10'X16'] RAISED STAGE WITH ACCESS RAMP.  ADD PARTITONS AND 4 NEW RESTROOMS.  ADD NEW MECHANICAL PLATFORM [10'X 23'].  MODIFY EXITING AND ADD FIRE SPRINKLERS. MAX 4 EMPLOYEES PER SHIFT FOR CAFE.. TOTAL NEW CONNECTED LOAD IS APPROX 250A OF CONNECTED LOAD - TOTAL AFFECTED AREA = 4525 SF - A OCC. LOAD >50.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25037	18041-10000-38405	6360 N RESEDA BLVD	91335	3	180B125   659	2124003035	C4-1VL-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	05/15/2020 12:00:00 AM		Permit Finaled	04/05/2021 12:00:00 AM	ADDRESS	34.18611	-118.53568	PC FOR POWER AND ENERGY FOR A NEW DRIVE-THRU STARBUCKS IN A NEW BUILDING. SCOPE INCLUDES NEW SERVICE (600A),  LIGHTING, EQUIPMENT AND RECEPTICALS. TOTAL AFFECTED AREA IS 19,695 SQ.FT. B # 18010-10000-04849	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25038	15041-10000-11056	19801 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	33.85115	-118.28659	REPLACING 4, HID FIXTURES WITH LED FIXTURES IN A WAREHOUSE. TITLE 24, PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25039	15041-10000-17996	885 S PIER A ST	90744	15	021B205   167	7440018905	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	33.75438	-118.27117	installation of a 5HP SUM PUMP ETHOD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25040	15041-10002-31181	13439 W CHANDLER BLVD	91401	4	171B157    52	2344010018	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Expired	01/05/2018 12:00:00 AM	ADDRESS	34.16871	-118.4258	12-04-2015 M.Z     down size from 69 modules two inv. to 31 modules and one inv.                                                                                                                                                         Installation of 16KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF SFD, PERMIT FEE WAVED DUE TO 2012 SENATE  # 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25041	14041-20000-31117	12944 W HARTSOOK ST	91423	4	171B161   714	2358030028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.16385	-118.41529	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL STANDARD INVERTER PLAN. SYSTEM SIZE: 6KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25042	17041-10000-11368	464 N FAIRFAX AVE	90036	5	141B177  1186	5527030026	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.07996	-118.36125	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM 2-STORY BANK W/ BASEMENT TO TRADE SCHOOL OF HAIRDRESSING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1042 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25043	17041-10000-24509	19801 W NORDHOFF PL #111	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.23568	-118.56464	T-24, PC FOR ENERGY ONLY. REPLACING EXISTING FIXTURES WITH LED FIXTURES FOR INDOOR USE. TOTAL AFFECTED AREA IS 9300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25044	10041-20000-09277	18225 W SHERMAN WAY	91335	3	186B125   889	2119028005	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.20134	-118.53046	New lighting in sales area and egress lighting. This P/C is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25045	15041-10000-36365	15123 W SHERMAN WAY	91405	6	183B145   778	2221019104	QR3-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.20147	-118.46262	NEW FIRA ALARM PANEL AND ADDITION OF DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25046	13041-20000-13413	12346 N YEW CT	91326	12	219B117   121	2701047017	[Q]RD6-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.29785	-118.56219	PV1 SINGLE FAMILY DWELLING TRANSFORMERLESS INVERTER NONSTANDARD PLAN TOTAL SYSTEM SIZE 4.2 KW. USING 12 MODULES. ROOF MOUNTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25047	13041-10002-12486	7203 N RUBIO AVE	91406	6	183B137    51	2226016015	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			01/31/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.20163	-118.49594	CHANGES TO APPROVED SET OF PLANS. DELTA 2 CHANGES ONLY. CHANGES IN LUMINAIRES. CHANGES ARE CLOUDED.CHANGES MADE TO THE PREVIOUSLY APPROVED SET , TITLE 24 FOR OFFICE AND BATHROOM AREA., ALSO PANEL FOR THIS AREA WAS REMOVED FROM HOUSE PANEL AND WAS ADDED TO THE RESIDENTIAL SECTION. AND ONE METER WAS   ADDED TO THE METER BANKS.   1-17-14  MZANDI   )))))))))((((((((PC FOR POWER/ENERGY. NEW 29 UNIT APT.4STORY.1ST FLOOR grade level  AND 3 STORies above. 8 typical units. not methane . fully sprinklered. engr = robert tomasiaCONSTRUCT NEW 29 UNIT APT AND SALE OFFICE AS AN ACCESSORY USE TO THE BUILDINGNO PROGRESS - PC APPROVE IS FOR GRADING PERMIT R&R ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25048	18041-10000-46401	4570 W COLORADO BLVD	90039	13	162B205   118	5593018015	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.14078	-118.27277	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25049	16041-10000-01574	3512 S GRAYSBY AVE	90732	15	009B189   488	7563019011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.71989	-118.31986	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1 roof mounted installation to a single family home. (1) inverter, Rating: 11.4 Kw, (51) Modueles.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25050	13041-20001-25692	19765 W RINALDI PL #100,200	91326	12	210B117   408	2701040041	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM			Corrections Issued	01/02/2014 12:00:00 AM	PIN	34.27524406	-118.56474153	RETAIL ENERGY PLAN CHECK (((plan check for changes to lighting. clouded delta 1 changes only, full plan check for single line. extension of 2000A bus)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25051	16041-20000-32340	3030 W 8TH ST	90005	10	132B197   465	5094012029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM			Reviewed by Supervisor	09/29/2016 12:00:00 AM	ADDRESS	34.0576	-118.29246	PV2.  Install 36.6 kW DC carport mounted solar system.  (120) modules with (2) 17.5 kW AC rated transformerless inverters. (2) systems are being submitted for the same address - same system size/details but interconnecting to different switchgears with separate meters.  System 1 of 2 - designated 'System A' on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25052	18041-10000-22440	5932 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	33.94435	-118.38715	PLANCHECK FOR T24 ENERGY ONLY FOR EXISTING KIT BUILDING AREA WITHIN UNITED AREA CARGO BUILDING - TOTAL AFFECTED AREA = 7182 SF BUILDING PERMIT # 18016-10000-15264	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25053	12041-20000-30677	9255 N WINNETKA AVE	91311	12	198B113   209	2748039027	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.23885	-118.57137	"Plan check for energy only. Only fixture type ""A2"" is being changed. ALL WIRING AND EMERGENCY LIGHTS ARE EXISTING. APPLEBEES. 5581sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25054	18041-10000-38210	750 S LAMAR ST DRIVER HEL-P CENTER	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (C) THE DRIVER HELP CENTER3 OF 10BUILDING PERMIT 13010-10000-01776	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25055	14041-20000-14189	12036 N WOOD RANCH ROAD	91344	12	216B129    91	2601068003	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.2904	-118.52416	PV1Install a 6kW solar array on roof of SFD.(1) SMA SB6000US-12 transformed inverter(20) Sunpower SPR-x21-345 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25056	17041-20001-19510	5230 N ETHEL AVE	91401	4	171B161   441	2345018052	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.16574	-118.41804	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (42) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25057	15041-10000-28877	4106 W JEFFERSON BLVD	90016	10	120B181   761	5046006004	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.02542	-118.34092	Energy plan check for a change of use from warehouse to office T.I. Scope includes new lighting equipment and receptacles. Total area is 2489-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25058	11041-20000-10923	12925 W RIVERSIDE DR 400	91423	4	168B161   392	2358021015	C1.5-1VL, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM			PC Approved	05/27/2011 12:00:00 AM	ADDRESS	34.15778	-118.41435	PLAN CHECK T24 ENERGY LIGHTING AND EMERGENCY T.I. FOR EXISTING OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25059	13041-10000-08655	350 S BIXEL ST SUITE 160	90017	1	132A209    99	5152014038	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.05673	-118.26007	T24 FOR EXISTING OFFICE SPACE. RELOCATING 24 LIGHT FIXTURES. 1568 SQRFT. SUITE 160. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25060	18041-10000-05885	1722 S TOBERMAN ST	90015	1	126A203   234	5135027018	R3-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.03903	-118.27821	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 16350 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25061	13041-10001-16658	455 N FAIRFAX AVE	90048	5	141B177  1235	5527031016	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	07/31/2013 12:00:00 AM	PIN	34.07973117	-118.3617853	TITLE 24 PLAN CHECK PER INSPECTOR REQUEST. EXPRESS PERMIT WAS PREVIOUSLY OBTAINED UNDER 13041 30000 16658.EXPRESS PERMIT DESCRIPTION [[[[[[ BASIC REWIRE FROM ELECTRICAL PANELS FORWARD]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25062	11041-10000-27303	12123 W GREENOCK LANE	90049	11	135B141   476	4402018024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2011 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	03/28/2012 12:00:00 AM	ADDRESS	34.06549	-118.47701	Roof mounted PV  system for SFD, 4.7KW and new additonal 200A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25063	18041-20001-35415	15860 W DARTFORD WAY	91403	5	159B141   320	2280025014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			PC Approved	09/22/2018 12:00:00 AM	ADDRESS	34.13247	-118.47933	Expedited plan check fee. PV1.  Install 11.16 kW roof mounted grid tied PV system.  (31) AC modules.  Derated main breaker rating.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25064	19041-10000-39025	10135 W HORSE HAVEN ST	91352	7	198B181    97	2544042002	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Issued	10/04/2019 12:00:00 AM	ADDRESS	34.23624	-118.35194	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10.24KVA PV1 SYSTEM CONSISTING OF 32 AC MODULES(SUNPOWER X22-360-D-AC) CONNECTED TO EXISTING 200A SERVICE   MAIN BREAKER DERATE UNDER SEPARATE PERMITDC SIZE = 11.52 kW DC sizeAC SIZE = 10.24 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25065	15041-20000-29142	4910 N ABBEYVILLE AVE	91364	3	168B093    82	2074022018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/31/2015 12:00:00 AM	ADDRESS	34.1596	-118.63201	Installation of new roof mounted solar PV array.  Total system size = 11.61 kW.  Central inverter system with 43 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25066	12041-10000-21733	3216 W SLAUSON AVE	90043	8	108B185   910	4005005028	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00, 2347.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	12/05/2012 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	33.98885	-118.32863	TI IN TWO EXISTING RETAIL STORE COMBINED INTO ONE.  T-24 TAILOR METHOD. COMPLETE PLAN CHECK MAY BE REQUIRED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25067	18041-10001-17063	2941 W 70TH ST	90043	8	102B189   584	4008011058	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	33.97648	-118.3254	"DELTA ""2"" CHANGES TO APPROVED PLANS ON PAGE E 2.0. UPDATING METER NUMBER (APMYV222-23194) AND NAME OF DISTRIBUTION BOARD TO ""MSA"" PER INSPECTOR'S REQUEST. THERE WERE NO CHANGES TO THE DESIGN OF PV SYSTEM.<<<25.06 kW AC CEC/ 33.3 kW AC SOLAR PHOTOVALTAIC ROOFTOP SYSTEM.82 PV Modules with Central Inverter. Building Permit: 18016-10000-14625>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25068	13041-10000-28867	9118 N REMICK AVE	91331	6	198B161   540	2629030029	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Expired	12/18/2015 12:00:00 AM	ADDRESS	34.23547	-118.40978	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A SINGLE STORY HOME. INTERCONNECTING WITH (N) 225A MAIN SERVICE PANEL. SYSTEM SIZE IS 3.75KW DC, & IS XFORMERLESS, WITH(15) MODULES: TRINA SOLAR #TSM-250PA05.18(1)INVERTER: POWER-ONE #AURORA PVI-3.6-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25069	15041-10001-19113	16940 W DEVONSHIRE ST	91344	12	204B133   217	2685002016	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			PC Approved	08/28/2015 12:00:00 AM	ADDRESS	34.25735	-118.50161	The only changes made to previously approved set is re arranging the track lights . no added watts or changes to controls. m.z                                                                                                                                                        Ti-24 TO AN E COMMERCIAL BUILDING, RALPH STORE. ADDING NEW LED TRACT LIGHT FIXTURES, 12 SQUARE FOOTAGE, 35,000. PLAN CHECK FOR ENERGY ONLY. EMERGENCY LIGHTING TO REMAIN PER APPLICANT. PER NM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25070	19041-10000-21635	7919 W SUNSET BLVD	90046	4	147B177   960	5551018008	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	02/25/2020 12:00:00 AM		Permit Finaled	07/15/2021 12:00:00 AM	ADDRESS	34.09821	-118.36239	T-24 PLAN CHECK FOR A TI IN AN EXISTING RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1370 SQ.FTB#19016-10000-15769	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25071	14041-10000-05480	420 E 3RD ST SUITE 910	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.04686	-118.24182	TI to existing commercial office space in an existing highrise office building.  Less than 400A of newly connected load.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25072	17041-10000-34479	312 S ALAMEDA ST	90013	14	127-5A215  66	5163010009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Closed	01/19/2018 12:00:00 AM	ADDRESS	34.04494	-118.23784	Full plan check for first time tenant office T.I. PER APPLICANTScope includes new panel and circuits. Total plan check area is 5,911 SQ FT.B#17016-10000-20717	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25073	18041-10000-25211	787 S ALAMEDA ST #140	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM			PC Approved	07/13/2018 12:00:00 AM	ADDRESS	34.03365	-118.24048	TI IN AN EXISTING COMMERCIAL AREA IN UNIT # 140. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25074	15041-20001-27104	600 WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	"Changes made to approved set.  Additional panel and water heater.  (((NEW ""OSTERIA"" RESTAURANT IN TERMINAL 6 OF LAX.NOTE: FIRST TENANT ON THE DISTRIBUTION PANEL.THERE ARE NOT ANY OTHER CONNECTED LOAD.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25075	19041-10000-48224	5820 S FIGUEROA ST	90003	9	108B201  1416	6004036029	C2-1-CPIO	South Los Angeles	South Los Angeles	Voices		2371.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	09/15/2022 12:00:00 AM		Permit Finaled	09/27/2023 12:00:00 AM	ADDRESS	33.98896	-118.28246	"FULL PLAN CHECK FOR A NEW 1000A 120/208V 3PH 4 W SERVICE WITH MULTIPLE SUBPANELS. HAZARDOUS LOCATION (GAS STATION-RETAIL). TOTAL AFFECTED AREA IS 91170 SQ.FTPer building permit #: 19010-10000-02961New 80'0"" x 41'2"" gas station retail store per ZA-2018-92-CUB-CU."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25076	14041-20000-26563	251 N BUNDY DR	90049	11	135B141   780	4402021024	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.06301	-118.47671	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(21) TRINA SOLAR TSM-245 MODULES(1) POWER ONE PVI-402-OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25077	19041-20000-13275	837 S SIERRA BONITA AVE	90036	4	132B177   370	5089016029	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Issued	04/11/2019 12:00:00 AM	ADDRESS	34.05961	-118.35513	INSTALLATION OF (2) 5KW TESLA POWERWALL BATTERIES, A 200A EMERGENCY PANEL, AND (2) 125A SUB PANELS TO A EXISTING SFD WITH A EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25078	15041-10000-05485	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake			2088.01	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.06281	-118.2731	NEW FIRE ALARM SYSTEM FOR EXISTING 5 STORY BUILDING. 422 DEVICES AND 1 FIRE ALARM PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25079	15041-10000-06347	415 S MAIN ST	90013	14	129A211    92	5149022010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM			PC Info Complete	07/14/2015 12:00:00 AM	ADDRESS	34.04769	-118.24782	Electrical improvements in (E) 6-story parking garage.  Replace distribution section of existing 3000A service and reconnect exsiting branch feeders, demo exisiting unit substation. installing new transformer and distribution panel.  PC for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25080	17041-10000-38259	2507 E 7TH ST	90023	14	123A221    12	5189009049	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.03221	-118.21649	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25081	18041-10002-03666	11846 N WOOD RANCH ROAD	91344	12	216B129   272	2601066001	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM			PC Approved	03/08/2018 12:00:00 AM	ADDRESS	34.28687	-118.52026	PC for changes to approved set. Changes include relocating inverter, AC disconnect and load center to inside of house. Installing perormance meter and AC disconnect. All changes clouded under delta 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25082	18041-20000-22304	3033 W WILSHIRE BLVD	90010	10	135B197  1240	5077008018	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2111.20	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM			Reviewed by Supervisor	07/03/2018 12:00:00 AM	ADDRESS	34.06198	-118.28733	Plan check for power and energy change of use from retail to restaurant newly connected load exceed 400A. Total area: 5656 sq ft B#17016-20000-29479	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25083	18041-10000-44898	6900 W MANCHESTER AVE	90045	11	096B161   690	4122022930	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.95947	-118.41159	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25084	13041-10005-34431	1243 S OLIVE ST	90015	14	126A207   200	5139023900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.03859	-118.26331	"06/02/16Changes to approved set of plans. All changes are made under delta 45. Changes include increasing the size of the feeder breakers to the apartment units from 100A to 125A, and addint new load equipment to distribution board ""MSH-B.""((((((9/28/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGING FEEDERS FROM COPPER TO ALUMINUM. REVISED ENERGY CALCS AND LIGHTING FIXTURES TO EXISTING AREAS.  NEWLY ADDED LOAD < 400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.  CHANGES NOTED UNDER DELTA 27.  NARRATIVE LETTER PROVIDED WITH SUBMITTAL.   POWER AND ENERGY PLAN CHECK FOR for New 7 Story (5 Story Type III-A over 2 Story Type IA Podium) Mixed Use Building w/293 Unit Apartment & Retail Building. Located in methane zone.ASSOCIATED BUILDING PERMIT: 13010-10001-02722"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25085	18041-20000-35891	6224 S FIGUEROA ST	90003	9	105B201  1037	6004038049	C2-1VL	South Los Angeles	South Los Angeles	Voices		2371.02	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	33.98261	-118.28245	ti to an existing gas station.  adding new lighting to the canopy and power to the dispensers.  plan check for hazardous location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25086	18041-10000-21398	225 E 5TH ST	90013	14	129A213   380	5148010900	PF-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Issued	05/21/2019 12:00:00 AM	ADDRESS	34.04567	-118.24671	FULL PC FOR POWER AND ENERGY FOR REHABILITATION OF (E) HISTORIC FIRE ENGINE HOUSE.  CORE & SHELL. TOTAL AFFECTED AREA IS 12755 SQ. FT. BUILDING PERMIT # 18016-10000-18190	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25087	17041-20000-28908	4625 W DUNDEE DR	90027	4	153B197     3	5588033018	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.11813	-118.28732	Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (35) modules, (35) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25088	10041-10000-17390	8230 W BEVERLY BLVD	90048	5	138B173   463	5511008004	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	09/30/2010 12:00:00 AM	ADDRESS	34.07591	-118.3692	TI IN EXISTING OFFICE- NEW CIRCUITS AND LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25089	18041-20001-06374	4643 W VANTAGE AVE	91607	2	168B165   778	2356036027	R1-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Issued	05/24/2018 12:00:00 AM	PIN	34.15531123	-118.3979661	Additional subpanel for energy storage system connections. (((Plan check for the addition of (3) Tesla PowerWalls onto an existing PV system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25090	19041-10000-33430	16846 W ARMSTEAD ST	91344	12	213B133   296	2610008020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.28227	-118.49959	[E-PLAN] PV1. NEW ROOFTOP SOLAR SYSTEM WITH BATTERY BACKUP  LG CHEM. SYSTEM CONSIST OF 20 MODULES ( SANYO 330), OPTIMIZERS (SE P400) AND ONE CENTRAL INVERTER (SE7600A-USS). PANEL UPGRADE TO 200A TO BE PERMITTED SEPARATELY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25091	09041-10001-13631	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM			PC Approved	08/05/2010 12:00:00 AM	PIN	33.94094587	-118.40577128	Change the priviously approved plan. Remove the UPS from panel DBA and add it to the panel EH1X. Plan check for the change. (((((((((((((((((((((((New building, LAX interim West Bus Terminal, a passenger waiting area.  Power and energy.))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25092	14041-20000-28067	17101 W ENADIA WAY	91406	6	183B133   183	2227021016	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.20026	-118.50572	PV1.  Install 6.16 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.  Zoning clearance previously obtained for this property under 14041-20000-27413.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25093	13041-10000-34605	11958 W BURTON ST	91605	6	192B165   616	2310003010	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.22061	-118.3938	PV1. ROOFMOUNTED SOLAR SYSTEM INTERCONNECTED WITH MAIN PANEL. TRANSFORMERLESS , UNGROUNDED SYSTEM. SYSTEM SIZE: 4.0 KW.(16) TRINA SOLAR TSM 250(16) SOLAREDGE OPTOMIZERS OP250(1) SOLAREDGE # SE3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25094	19041-10000-14908	17183 W SUNBURST ST	91325	12	195B133    30	2690001007	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	08/11/2020 12:00:00 AM	ADDRESS	34.23461	-118.50843	pc for pv. system include (21) modules (panasonic VBHN330SA17), 1 central inverter (solaredge 6000H) and (1) 225A load center. system size is 6.93KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25095	19041-20002-05322	2701 N GLENDOWER AVE	90027	4	153B197   104	5588020030	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.11628	-118.29464	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25096	10041-10000-20780	14006 W RIVERSIDE DR # 243	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	Tenant improvement in retail storeplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25097	18041-10000-29318	660 S FIGUEROA ST # 1050	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR T24 ENERGY ONLY FOR OFFICE TI IN A HIGH RISE (10TH FLOOR). TOTAL AFFECTED AREA 2976 SQ.FTSCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS. B# 18016-10000-19603	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25098	12041-10001-23833	11351 N DRONFIELD AVE	91331	7	210B165     6	2532009009	A2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.27673	-118.4036	applicant to bring copy of approved set for the supplemental.CHANGES TO APPROVED SET OF PLANS. REARRANGED LIGHTING (indoor-basement bathroom,ground floor non-classroom areas,second floor - restrooms and corridor /outdoor-building perimeter) . added some receptacles in non-classroom areas.  ADDED 5 BRANch circuitsPlan check power and energy for new K-2 primary school (charter school) building. Building supplied with two 800A service. Special permission has been filed for multiple service laterals. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25099	16041-10000-37456	17052 W GALESBERG ST	91344	12	216B133   641	2607002020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.28483	-118.50397	Installation of new roof mounted solar PV array on exisitng single family dwelling.  Total system size = 6 kWac.  Central inverter system with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25100	18041-10000-11920	15119 W OXNARD ST	91411	6	177B145   429	2242026006	M3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.17957	-118.46243	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25101	10041-10003-25799	3310 S CENTRAL AVE	90011	9	117A209   419	5114026***	(T)(Q)C2-1L	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	08/06/2011 12:00:00 AM	ADDRESS	34.01319	-118.25635	COFFEE SHOP.  FIRST TIME TENANT, FULL PLAN CHECK REQUESTED PER APPLICANT.  PLAN CHECK IS FOR POWER.  T-24 IS ALREADY PREVIOUSLY APPROVED ON 10041-10002-25799	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25102	13041-20003-16324	11929 W COURTLEIGH DR	90066	11	111B157  1103	4233018006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			03/18/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	33.99687	-118.41943	[[[[3/18/15  CHANGES TO APPROVED SET. DELTA 4 CHANGES ONLY. CHANGING 171 SQFT OF UNCONDITIONED AREA TO CONDITIONED LOBBY AREA WITH INSTALLATION OF LIGHTING]]]]][[[2/26/15 CHANGES TO APPROVED SET. DELTA 3 CHANGES ONLY. UPDATING PLANS TO REFLECT INSTALLATION PER INSPECTORS REQUEST AND MINOR LIGHTING CHANGES]]]revisions to permitted set of plans:residential distribution board is rated 1phase 3W INSTEAD OF 3PH 4W;SUMP PUMPS AND BOILER EQUIPMENT ARE REMOVED AND EV CHARGERS UPSIZED; ALL CHANGES ARE CLOUDED; SERVICE LOAD CALCULATIONS WERE REVISED ACCORDINGLY(((((((((New 4-story 22-unit apartment building.  Power and energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25103	10041-10001-16687	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.09787	-118.31961	(((((((((((((((( Some branch circiuts from the previously approved plans got moved around because of removal of some mechanical equipement. Addition of 3 panels. Fire alarm is deferred and will require a variance ))))))))))))))))      New 10 story mixed use trade school building. Plan check for power and energy. (T24 fee is not included)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25104	17041-10000-18633	6000 S WEST BLVD	90043	8	105B185   425	4006006001	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM			No Progress	06/09/2017 12:00:00 AM	ADDRESS	33.98513	-118.33503	Plan check for Title 24.  New 1 story daycare building with 200 amp service.  Total area = 1,163 sq. ft.       Building permit #14014-10001-00142	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25105	14041-20001-17527	9145 N BALCOM AVE	91325	12	198B129   363	2766004009	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.23745	-118.52169	Expedited plan check per applicant request.  PV1.  Install 6.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25106	15041-10000-04905	8401 N TELFAIR AVE	91352	6	192B169   428	2632023061	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.22265	-118.38241	Plan check for Title 24 only. Project site is an existing building. Total lighting area = 16,140 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25107	12041-10000-18970	5420 W SUNSET BLVD	90027	13	147A193   107	5544032018	C2-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM			PC Approved	08/13/2012 12:00:00 AM	ADDRESS	34.09788	-118.30823	Plan check T24 Energy/Emergency lighting for new meat service area remodel at existing Food 4 less store. less than 400A load installation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25108	15041-20001-22270	20933 W HEMMINGWAY ST	91304	3	189B109   516	2109013015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.2145	-118.58989	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (48) modules, (1) combiner box, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25109	16041-20000-24637	10730 N MEMORY PARK AVE UNIT E	91345	7	207B145   239	2649003028	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.26537	-118.46322	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED TO MSP FOR UNIT E.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25110	15041-10000-02730	2025 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.05978	-118.20504	PC FOR POWER AND ENERGY. T.I. to existing building. NOT HIGH RISE BUILDING. MEDIUM  VOLTAGE DISTRIBUTION, TWO TRANSFORMER SUBSTATONS BEING FED FROM THE MEDIUM VOLTAGE. NEW PANELS  AND ONE UPS SYSTEM. TOTAL AREA 600 SQ FT.B# 14016-10000-19285.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25111	14041-20000-30307	186 W 40TH PL	90037	9	115-5A203 237	5111023010	RD2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.00987	-118.27596	PV1CENTRAL STRING INVERTER STANDARD PLAN SIZED 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25112	17041-10000-01759	1320 E 7TH ST 513 & 521	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Issued	01/24/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	PC FOR T24. TI TO RETAIL SPACE. NEW LIGHITNG. SUITE 513 AND 521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25113	15041-10000-06690	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 3380. SCOPE OF WORK TO BE PERFORMED IN THE LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25114	11041-10000-26880	400 S HOPE ST 4th flr-restrm	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM			PC Approved	12/16/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	T.I. with lighting change to the 4th floor restroom of a high-rise commercial building.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25115	19041-10000-51259	548 N MUSKINGUM AVE	90272	11	126B121   190	4414004010	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Issued	12/20/2019 12:00:00 AM	ADDRESS	34.04402	-118.53898	0$ FEE DUE TO AB1414. CHANGES TO APPROVED SET TO REMOVE THE POWERWALL'S  AC DISCONNECT AND RELOCATE EQUIPMENT TO MATCH EXISTING CONDITIONS.  MASTER PLAN UNDER 19041-10000-50694	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25116	12041-20000-04833	5339 N SADRING AVE	91367	3	171B093   147	2044014012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2012 12:00:00 AM	04/06/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.16767	-118.6366	9.21 KW ROOF  MOUNTEDSOLAR SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25117	17041-10002-40594	10250 W SANTA MONICA BLVD #1893	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Changes to approved plan for tenant ""Malin + Goetz""  suite 1893, changes noted under Delta-4: Revise lighting floor plan, revise T24 information accordingly, add (2) ckts for floor display and ceiling receptacles."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25118	14041-10000-27897	7026 W 85TH ST	90045	11	096B161   555	4113004024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	33.96055	-118.41469	PV 1 STANDARD PLAN CHECK 4.73KW, 2 STRINGS, 22 MODULES MIROC-INVERT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25119	19041-30000-23737	107 N DELFERN DR	90077	5	141B157   130	4358005006	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	34.08012	-118.42866	Changes to an approved set of plans. All changes have been clouded and marked as Delta-2 with updating feeder to proper size.********orginal PC#: 16041-20000-44903                                            16041-30001-44903	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25120	16041-10000-05464	711 N COLE AVE 1-84	90038	13	141B185   510	5533034030	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Issued	02/29/2016 12:00:00 AM	ADDRESS	34.08393	-118.33015	PC FOR A NEW FIRE ALARM SYSTEM FOR A 4 STORY, 84 UNIT APARTMENT WITH SUBTERRANEAN GARAGE. SCOPE INCLUDES 304 FA DEVICES, 1 FA PANEL, AND 1 COMM. PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25121	19041-20000-04757	8353 W GRAND VIEW DR	90046	4	148-5A175  22	5556019020	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2019 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.10318	-118.37269	Plan check for Battery Energy storage system installed in to existing PV system. Tesla Power Wall 13.5KWh, and 200A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25122	17041-10000-12333	770 W MIRAFLORES AVE	90731	15	021B197   511	7447022027	[Q]CM-1VL	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Info Complete	04/17/2017 12:00:00 AM	ADDRESS	33.75296	-118.29393	Title 24 plan check.  T.I. to warehouse and office space.  New lighting and receptacles.  Total area = 3,963 sq. ft. (indoor) + 321 sq. ft. (outdoor)     Building permit #16016-10000-31188	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25123	13041-10000-19185	621 S WESTERN AVE	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	TITLE 24 PLAN CHECK ONLY. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 706 SQFT. WORK ON THE BOTTOM FLOOR. AROUND 4 STORIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25124	15041-10001-42408	8856-8858 W PICO BLVD	90035	5	132B169   923	4305014007	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	34.05485	-118.38504	04/18/16Changes to an approved set of plans. All changes are made under delta 2. Scope includes relocating the 600A main distribution board, and subpanels. Also, the pull section from the main distribution panel is changed from an underground pull section to an overhead pullsection. NOTE: Permit paid under PCIS#15041-10000-42408(((((FULL PC, FOR POWER AND ENERGY.  CHANGE OF USE TO A MARKET AND TAKE OUT RESTAURANT. UPGRADING SERVICE TO 600 AMPS WITH  NEW ELECTRICAL EQUIPMENT. TOTAL SQ. FT. 2,931.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25125	13041-10001-23793	6611 N FAIR AVE	91606	2	180B173   457	2319012006	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.19073	-118.37482	SUPPLEMENTA PLAN CHECK TO 13041-10000-23793. REMOVING 1 MODULE AND CHANGING THE INVERTER.ORIGINAL PC: PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3 KW USING 13 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25126	16041-10000-05365	2029 S CENTURY PARK EAST 250 N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, PC  FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 2ND FLOOR (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND 1 NEW 225A PANEL. TOTAL AFFECTED AREA IS 11,165 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25127	15041-20001-26376	22621 W VENTURA BLVD	91367	3	171B097   167	2040028011	(Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	PIN	34.16779098	-118.6196637	Expedited per customer request.PV2. Install roof mounted PV system sized 100 kW. Interconnected with main service panel.(360) Canadian Solar CS6X-310(1) Solectria PVI 100 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25128	14041-20000-34553	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM			Corrections Issued	12/12/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MARKET. NO CHANGE IN OCCUPANCY.  1223 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25129	11041-20000-17943	6555 W FOOTHILL BLVD	91042	7	201A203   106	2570019008	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	10/06/2011 12:00:00 AM	ADDRESS	34.24594	-118.27468	Plan check T24 Energy/emergency lighting for existing Smart & Final TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25130	17041-10000-28181	10250 W SANTA MONICA BLVD #1450	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for medical office / clinic ""FORWARD"" located in Westfield Century City Ste#1450. Total area: 1,735 sq.ft, power fed from MS-ELA11"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25131	15041-20000-38613	4560 N SHERMAN OAKS AVE	91403	5	168B145   957	2283023004	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Info Complete	11/16/2015 12:00:00 AM	ADDRESS	34.15361	-118.46888	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (VETERINARY CLINIC). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 2392 SQ. FT. NOTE: PERMIT FEES PAID UNDER PCIS# 15041-20000-37195	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25132	10041-10000-03077	6215 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			02/22/2010 12:00:00 AM	04/23/2010 12:00:00 AM		Permit Finaled	07/01/2010 12:00:00 AM	ADDRESS	34.18351	-118.60617	TENANT IMPROVEMENT IN YOGURT SHOP.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25133	18041-20002-06441	2449 N ARBUTUS WAY	90049	11	141B133   206	4492028019	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	34.08145	-118.50303	10/05/2018 Changes to an approved set of plans. Changes have been made to the interconnection configuration of the PV, battery back-up, and generator systems.*****Previous Work Description*****PV1.  Install 9.72 kW (27 AC modules) PV system with battery backup and standby generator using Sonnen Battery System Eco 16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25134	12041-10000-05576	12222 W WILSHIRE BLVD Unit #101	90025	11	126B145   356	4263001***	[T][Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	06/06/2012 12:00:00 AM	ADDRESS	34.04288	-118.46867	Existing restaurant will take over existing adjacent restaurant to make one larger restaurant.  PLAN CHECK  for Energy with Emergency lighting.  Existing Panels, Permit was issued for 14 new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25135	17041-10000-22313	6350 W FOOTHILL BLVD	91042	7	198B205   113	2572009018	(Q)C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.24232	-118.26967	PC for Fire alarm with 1 fire alarm panel, 1 annunciator and 3 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25136	18041-10000-33304	20945 W OSBORNE ST	91304	3	195B109    45	2779001040	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.23316	-118.59	REPLACE INDOOR-OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25137	14041-10000-09483	1266 S WESTWOOD BLVD	90024	5	132B153   538	4325005024	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.05758	-118.44292	T24 FOR EXISTING RESTAURANT. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A AND OCCUPANT LOAD DOES NOT EXCEED 99. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25138	18041-30001-37761	1100 S GLENDON AVE #710	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	PC FOR ENERGY ONLY, TENENT IMPROVEMENT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 5240.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25139	17041-10000-40179	17431 W ROSCOE BLVD	91325	12	192B129   252	2787018006	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.22122	-118.5136	REPLACE OUTDOOR LUMINAIRES WITH LED TYPESPLAN CHECK IS FOR TITLE 24 ONLY103175 SQ.FT OUTDOOR.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25140	12041-10001-18166	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM			PC Approved	10/26/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	(((((SUPPLEMENTAL TI CHANGES TO APPROVED SET OF PLANS) )))))PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T.I. FOR OFFICE #1100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25141	17041-20000-34249	11133 N BALBOA BLVD	91344	12	210B133   328	2697025004	(T)(Q)C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Issued	09/25/2017 12:00:00 AM	ADDRESS	34.27305	-118.50254	Install new LED fixtures on (E) poles in (E) parking lot.  No new or altered circuits.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25142	15041-10000-13108	15350 W SHERMAN WAY SUITE 255	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.20099	-118.46808	TI FOR EXISTING LOWRISE OFFICE BUILDING. DEMO EXISTING LIGHTS REPLACE WITH NEW WIRING AND CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25143	13041-10001-24290	4900 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM			PC Info Complete	07/10/2014 12:00:00 AM	ADDRESS	34.09786	-118.29626	[[[6/9/14]] CHANGES TO APPROVED SET. DELTA 1 AND DELTA 6 CHANGES ONLY.  RELOCATING PANELS AND EQUIPMENT. ALONG WITH ADDITION OF NEMA 3R CABINET. Replacement of emergency generator, addition of life-safety ATS, panels and emergency lighting medical office building (6 story low rise building)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25144	19041-20000-23209	360 E 2ND ST 6TH FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.04805	-118.24012	Plan check for Title 24 only in existing space 6th Floor high-rise building, Tenant Improvement. Total area: 11932 sq ft. B#19016-10000-14457	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25145	15041-20000-24446	9605 W ROYALTON DR	90210	4	150B165    76	4387023003	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.11061	-118.40512	PC FOR PV SYSTEM. 6KW AC USING 26 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25146	18041-20000-01778	1420 N COIL AVE	90744	15	036B213    16	7426029007	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Issued	02/27/2019 12:00:00 AM	ADDRESS	33.79347	-118.24241	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor parking lot lighting. Total lighting area = 701,703 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25147	14041-10000-00240	1100 S WALL ST #104	90015	14	124-5A211  88	5145024026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.03625	-118.25418	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 630 SQFT. ALL WORK DONE ARE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25148	13041-10000-28062	1106 S GAFFEY ST	90731	15	015B197  1244	7454018027	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Approved	10/09/2013 12:00:00 AM	ADDRESS	33.73403	-118.2922	TITLE-24 , PART 6, LIGHTING PLAN CHECK ONLY. REMOVING HID LIGHT FIXTURES AND INSTALL NEW FLOURESCENT FIXTURES. TOTAL AREA TO BE 2856.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25149	13041-10001-34488	6320 N TOPANGA CANYON BLVD BLD # G	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	06/22/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Changes to an approved set of plans. Changes include relocating load circuits. No new circuits or panels added. All changes are clouded. Approved for submittal per F.Y.*****Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING G.BUILDING PERMIT # 13010-10000-02910.New  retail  bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25150	18041-10000-21257	3671 S WESTERN AVE	90018	8	120B193  1609	5041023053	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Public Safety Only			06/07/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.02138	-118.30918	PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. SCOPE INCLUDES 143 FA DEVICES AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25151	19041-30000-11930	2029 S CENTURY PARK EAST D Level	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	06/04/2021 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is the elevator lobby on the D level of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,050 sq. ft.Note: Building permit has been issued under 19016-10000-03144	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25152	11041-10000-00136	357 N FAIRFAX AVE	90048	5	138B177   122	5527036013	C2-1VL	Central	Wilshire	Mid City West		1945.00, 2144.00	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	PIN	34.07777954	-118.3617743	FOR AN EXISTING 2-STORIES COMMERCIAL BUILDING, NEW SERVICE, HOUSE PANEL, BRANCH CIRCUITS, AN A 25HP ELEVATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25153	13041-10000-28838	1925 S CENTURY PARK EAST STE 260	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.06066	-118.41426	TITLE-24 , PART 6, ENERGY , PLAN CHECK FOR COMMERCIAL HIGH-RISE BUILDING. THE USE OF THE SPACE WILL BE FOR OFFICES. TOTAL AREA IS 3119 SQ FT. EMERGENCY ILLUMINATION WILL BE FED VIA EXISTING EMERGENCY CKT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25154	16041-10000-23552	1100 S GLENDON AVE 7TH FLOOR	90024	5	132B153   215	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.06074	-118.44418	PC for energy only to a corrider on 7th floor of a high rise bulding (offices). Installing new lighting only. Total sqft = 1490	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25155	13041-10000-27556	604 E ROSE AVE	90291	11	111B145   964	4240011047	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	33.99915	-118.47166	installation of optional standby system for loads in the ITA room-generator outside with tranfer switch and 200A distribution board	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25156	15041-20000-23239	15301 W VENTURA BLVD Ste 250	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for Title 24 only. Project site is an existing comercial space. Project scope is a tenant improvement. Total lighting area = 9,225 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25157	18041-10000-21713	530 N FICKETT ST	90033	14	129A225   137	5177026001	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.0484	-118.2041	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25158	17041-10000-33070	137 N VIRGIL AVE	90004	13	138B197   628	5501007027	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.07469	-118.28704	PC for T24 only for new lighting in first and second floor. Total 15120sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25159	15041-20000-31339	20364 W LANDER DR	91364	3	168B113   411	2174018002	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Expired	10/18/2017 12:00:00 AM	ADDRESS	34.15502	-118.57707	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (33) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25160	15041-10000-18373	19953 W RINALDI ST	91326	12	210B113   187	2701040018	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.2758	-118.56956	Energy plan check for a restaurant (Pieology ) T.I ; Scope include new equipment, receptacles and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25161	19041-10000-45204	6200 W HOLLYWOOD BLVD #108	90028	13	148-5A189 354	5546028037	[T][Q]C4-2D, [T][Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	09/02/2022 12:00:00 AM	ADDRESS	34.10136	-118.32459	FULL PC FOR A TI (FIRST TIME), SCOPE OF WORK INCLUDES A NEW 75 KVA TRANSFORMERS, A NEW 225A PANEL, ALL CONNECTED TO AN EXISITNG SERVICE SWITCHBOARD. TOTAL AFFECTED AREA IS 1902 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25162	13041-10002-30132	10458 N DES MOINES AVE	91326	12	207B117   448	2728007009	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	34.26049	-118.55459	Expedited RSES plan check per applicant request.(((PV1, Install 9 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 36 modules Fronius IG Plus V 7.5.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25163	13041-20000-21772	21800 W OXNARD ST SUITE 350	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.17898	-118.60253	TI. RENOVATION OF EXISTING OFFICES. NEW PARTITIONS. PC FOR T24 ENERGY ONLY. TOTAL AREA 1012 SQFT. PERMIT TO BE ISSUED UNDER THIS APPLICATION. WORK DONE IN UNIT 350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25164	18041-10000-03812	14626 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.22128	-118.45073	FULL PC FOR POWER AND ENERGY FOR A NEW SHELL BUILDING. SCOPE INCLUDES A NEW 1200A 120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 23014 SQ. FT. B#18010-10000-00386	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25165	16041-10000-01424	10451 W SANTA MONICA BLVD	90025	5	132B157   742	4326032025	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.05657	-118.42598	Energy plan check for restaurant (Mc donald)  T.I. Scope includes new lighting and receptacles. Total area is 2794-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25166	15041-10001-43361	767 S ALAMEDA ST Bldg 2	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.03474	-118.24063	CHANGES TO APPROVED SET.  CHANGES TO LIGHTING LAYOUT OF SITE LIGHTING.  TOTAL AREA = 31,200 SQ. FT.ALL CHANGES CLOUDED   *****************************   THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER.    *****************************ORIGINAL PROJECT IS A RENOVATION OF EXISTING 6 STORY BUILDING AND CHANGE OF USE TO OFFICE/RETAIL/RESTURANT USES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25167	15041-20002-42773	10310-10440 N SEPULVEDA BLVD Bldg 4	91345	7	204B145   259	2649019007	C2-1, CR-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	08/01/2017 12:00:00 AM	ADDRESS	34.25776	-118.46707	Original approved plan set lost.  New 1600A switchboard and panels.  Indoor and outdoor lighting.  Plan check for power and energy.  11.14.2016 - Plan check for power only. New 1200A switchboard. New panels (4H, 4D, 4EV, and 4DPE). New house loads. ======T-24, ADDITION TO COMMERCIAL BUILDING AND MAINTENANCE ROOMS AND REMODEL OF EXTERIOR FACADE. SCOPE OF WORK INCLUDES NEW LIGHITNG. TOTAL SQ. FT. 3684	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25168	10041-20000-20043	6120 N YOLANDA AVE	91335	3	177B121   497	2127016018	MR1-1, P-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/08/2010 12:00:00 AM		Permit Closed	12/20/2012 12:00:00 AM	ADDRESS	34.18132	-118.54025	outdoor energy plan check indoor bathrooms and permit for water heater	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25169	18041-10000-34878	777 S FIGUEROA ST #800, #850	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	2 EA LUMINAIRES IN NEW OPEN OFFICE AREAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25170	16041-20000-39253	1315 E OPP ST	90744	15	033B213   613	7425033022	[Q]R2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Closed	09/20/2017 12:00:00 AM	ADDRESS	33.78382	-118.24702	pv1install roof mounted pv system sized 2.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25171	11041-10000-27132	9840 N LASAINE AVE	91325	12	201B129   110	2755013028	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.2499	-118.51257	New PV system for a single family house. EPC is for power. Clearance was filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25172	16041-20000-02996	11318 W SANTA MONICA BLVD	90025	11	129B149   524	4261009032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.04615	-118.44897	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,395 sq. ft.Note: Building permit has been pulled under 16014-30000-00034	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25173	13041-10000-27141	17544 W LANARK ST	91325	12	189B129   143	2201005009	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.21786	-118.51582	PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 4 kW. TRANSFORMERLESS INVERTER. TWO STORY.(16) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-3.6-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25174	15041-20002-20305	7950 W SUNSET BLVD 102	90046	4	147B177  1021	5554003055	(Q)RAS4-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.09777	-118.36322	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE USE OF MULTIWIRE BRANCH CIRCUITS. CHANGE TO SERIES RATING COMBINATION. ALL NOTES CLOUDED DELTA 3 REVISIONS. permit already on job, this application is plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25175	13041-10000-00700	1742 S GRANVILLE AVE	90025	11	126B149   936	4262016***		West Los Angeles			Y	2675.01	Electrical	Electrical	Apartment			01/10/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	PIN	34.03945817	-118.45480308	New roof mounted PV for a 2-story apartment building with 4.08 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25176	14041-20000-09982	8941 N TAMPA AVE	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.23285	-118.55413	tenant build out. new salon in existing retail space. full plan check for power and energy. load greater than 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25177	13041-10000-22596	6834 W HOLLYWOOD BLVD 1ST FLOOR	90028	13	148-5A185 161	5548006015	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.10138	-118.33965	TITLE-24 PLAN CHECK ONLY. ELECTRICAL MODIFICATION FOR ALTERATION TO AN EXISTING RESTAURAN & RETAIL FOR 1ST FLOOR, MEZZ,KITCHEN. LOCATION IS IN HIGH-RISE. WORK IS DONE ON FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25178	18041-10000-03990	5047 N RADFORD AVE	91607	2	171B169   677	2355002014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM			Corrections Issued	02/02/2018 12:00:00 AM	ADDRESS	34.16271	-118.39229	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 35 MODULES WITH OPTIMIZERS WITH CENTRAL INVERTERSYSTEM SIZE 10.15KWDC/ 10KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25179	17041-10000-39081	11111 W SANTA MONICA BLVD FLR 19, 20	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC for ofice TI 19TH AND 20TH FLOORS. SCOPE INCLUDES NEW LIGHTS, RECEPTICALS AND CIRCUITS. TOTAL EFFECTED ARE 881 SQ-FTB#17016-10000-32024	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25180	18041-20003-26393	3732 W CLAYTON AVE	90027	4	148-5A203 330	5430009015	R1-1	Central	Hollywood	Los Feliz	Yes	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.10052	-118.27558	12/10/2018changes to an approved set of plans.  changes to relocate inverter in garage.this is plan check only.  ((((10/4/2018changes to an approved set of plans.  changes to relocate battery and AC disconnect in garage.this is plan check only.))))((((pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.(22) solar city 325W modules(1) delta solivia 7600 string inverter(1) tesla energy storage device 5KW))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25181	15041-30001-40310	1676 E 108TH ST	90059	15	088-5A213  73	6069002006	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	33.93769	-118.24341	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Single inverter system.  Address is not available for online permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25182	16041-20000-25630	100 WORLD WAY T1 #120	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	33.94572	-118.40095	Plan check for Title 24 only in existing space space # 120. Total area: 1,465 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25183	18041-10000-25606	3201 W WILSHIRE BLVD	90010	10	135B197  1225	5502025007	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2121.01	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM			PC Info Complete	07/10/2018 12:00:00 AM	ADDRESS	34.06197	-118.29195	NEW METHANE GAS CONTROL SYSTEM IN A NEW CVS PHARMACY.BUILDING PERMIT # 18010-10000-03341	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25184	18041-20000-05522	345 E 51ST ST se park-lights	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	33.99665	-118.26853	plan check for outdoor energy lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25185	11041-20000-15659	515 S FIGUEROA ST SUITE#320	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM			Corrections Issued	07/26/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI IN AN EXISTING OFFICE. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25186	15041-20000-40311	7259 N NESTLE AVE	91335	3	186B125   870	2119026004	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.203	-118.53079	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac. (48) MODULES-KYOCERA #KU2656ZPA(2)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25187	07041-10005-05924	16710 W VENTURA BLVD	91436	5	168B137   335	2289020018	(T)(Q)C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Apartment			04/08/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.15819	-118.49729	125 unit apartment and retail. Recheck of Expired Plans based on the new code requirements.  MAIN PERMIT IS TO BE PULLED UNDER THIS NUMBER (07041-10005-05924) .THE PERMIT FEES ARE UNDER INSPECTION FEES DUE TO THE MANY CHANGES IN PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25188	15041-10000-27654	700 S FLOWER ST 25TH FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC OF ENERGY ONLY ON EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING IN CORRIDORS AND BATHROOMS ON THE  25TH FLOOR. TOTAL AREA = 1213 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25189	14041-20001-32510	13122 W PAXTON ST	91331	7	213B161   715	2533002005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.27898	-118.41858	expedite per customer request.pv1install roof mounted pv system sized 6.0kw interconnected with msp.(18) sunpower 327w modules(1) aurora 6k transformerless inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25190	11041-20000-08088	127 S SAN VICENTE BLVD Bulletin-54	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 54	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25191	17041-20000-44707	10677 N EL DORADO AVE	91331	7	207B157   634	2620006008	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.26408	-118.42306	PV1.  Installing 2.95 kW DC roof mounted grid tied PV system.  (E) PV system previously permitted on site.  Microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25192	18041-10000-37738	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Issued	02/28/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	PLANCHECK FOR POWER AND  ENERGY. TENANT IMPROVEMENT FOR INSTALLATION OF GATE MOTORS, ELEVATORS AND  LIGHTING IN TERMINAL 5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25193	16041-10010-01886	700-800 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET. CHANGES NOTED DELTA 42 ON PLANS.SCOPE INCULDES ADDITION OF PANELS, CIRCUITS, EQUIPMENT AND TITLE 24 REVISIONS (INCLUDING SQ. FT ADDITION).ADDED SQ. FT 211	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25194	10041-20000-00041	16350 W VENTURA BLVD SUITE B	91436	5	168B137   410	2284001055	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			01/04/2010 12:00:00 AM	01/04/2010 12:00:00 AM		Permit Finaled	02/02/2010 12:00:00 AM	ADDRESS	34.15688	-118.48955	Shell build-out/landlord work for future tenant. Electrical plan check is for Power and Energy. Contractor is also the owner.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25195	12041-10000-21635	8719 N VARIEL AVE	91304	12	195B105   215	2779016005	(T)R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34, 1134.21	Electrical	Electrical	Apartment			09/12/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.22877	-118.5932	New 19 units appartment BLDG. EPC is for power & energy. (modification for a separate fire alarm system was filed)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25196	16041-30000-18205	11050 W SANTA MONICA BLVD	90025	5	129B153   810	4323019052	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	34.04783	-118.44275	Plan check for Title 24 only.  Project site is an exising commercial building. Project scope is a tenant improvement. Total lighting area = 662 sq. ft.Note: Building permit has been pulled under 15016-20000-28459	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25197	12041-20000-01686	9800 N WHEATLAND AVE	91040	2	201B177   235	2543030022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.24776	-118.3573	pv system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25198	18041-10001-02329	3411 N MANDEVILLE CANYON ROAD	90049	11	150B133    65	4491006006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM			Reviewed by Supervisor	01/30/2018 12:00:00 AM	ADDRESS	34.10623	-118.50288	Expedited FeesPV 1, Roof Mounted solar system to a single family dwelling with AC energy storage batteries. (1) 7.6KWAC inverter, (29) modules, (2) AC tesla batteries and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25199	14041-10001-19675	5507 W HOLLYWOOD BLVD	90028	13	148-5A193 129	5544005029	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM			PC Approved	08/04/2014 12:00:00 AM	ADDRESS	34.10192	-118.30983	((11-04-14 SUPPLEMENTAL TO APPROVED SET PER INSPECTOR REQUEST. ADDITIONAL 6 DEVICES ))FA FOR MARSHALL'S. 5507-B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25200	19041-20000-22391	2311 N ACHILLES DR	90046	4	153B177   481	5569007051	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.11279	-118.36577	Install 27 kWh / 10 kW rated energy storage system.  Relocation of house loads to existing critical load panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25201	17041-10000-22195	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004161	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Closed	06/29/2021 12:00:00 AM	ADDRESS	34.05715	-118.41482	Power plan check for a temp power; Scope include 1200 amp, 4160 V, 3P, 3W service, 32 panelboards, 127 equipment and 24 ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25202	11041-10000-25369	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	PIN	33.92817449	-118.43220714	removing MCC 39AA and refeeding its existing loads and new loads from existing MCC -25; SIMILARLY' removing MCC 39BA and refeeding its existing loads and new loads from existing MCC -26;USING  AN EXISTING PANELBOARD LP-25 AND NEW PANELBOARDS RP-26A & LP-25A TO SUPPLY NEW EXTERIOR  LUMINAIRES ( LEDS ) AND ELECTRICAL EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25203	18041-10001-37226	659 S BROADWAY	90014	14	129A211   258	5144003040	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.04551	-118.2533	PLAN CHECK FOR POWER ONLY FOR REPLACEMENT OF EXISTING 250 KW GENERATOR WITH TRANSFER SWITCH, CONNECTED TO EXISTING DISTRIBUTION SYSTEM, GENERATOR PAD AND GROUNDING. ALL EQUIPMENT IS 65KAIC RATED TO MATCH EXISTING EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25204	14041-10000-31966	7715 N DENSMORE AVE	91406	6	189B141   266	2206010005	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.21086	-118.47725	Energy plan check for an Industrial work  T.I. Total area cover 6538 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25205	17041-20001-14475	812 W 165TH PL	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/10/2017 12:00:00 AM	ADDRESS	33.88061	-118.28977	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTERS. SYSTEM SIZE: 50KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25206	15041-20000-16960	9859 N SAN FERNANDO ROAD BLDG B	91331	7	201B165    89	2624019013	M2-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	34.24923	-118.40471	PLANCHECK FOR POWER AND ENERGY FOR   2 SEPERATE MACHINE SHOP BUILDINGS AND INSTALLATION OF A PANEL ON 3RD BUILDING .  [BUILDING B : 6977 SQFT]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25207	13041-10000-36277	1145 S TOWNE AVE STE #7	90021	14	123A211    25	5132010047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.03301	-118.2507	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 338 SQ FT. REPLACING TOTAL OF 2 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25208	15041-10000-27928	17508 W VINTAGE ST	91325	12	204B129   535	2734019009	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.25196	-118.51611	PV1, INSTALL 10.46 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: SUNPOWER SPR327NE(2) INVERTERS: ABB PVI-5000-OUTD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25209	12041-10000-13798	1241 S SOTO ST	90023	14	121-5A221 147	5170017030	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	34.02743	-118.21975	Plan check for energy and emergency lighting. Occupancy load is 88 per building plans. 756 sqft scope of work for lighting. 2 story commercial building. Chase	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25210	13041-10000-18362	196 E JEFFERSON BLVD	90011	9	118-5A205 315	5120007006	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.01717	-118.26972	REMODELING EXISTING MANUFACTURING BUILDINGADDED LOAD IS LESS THAN 400APLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25211	17041-10000-11266	18267 W SHERMAN WAY	91335	3	186B125   894	2119028015	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.20134	-118.52976	PC FOR ENERGY. TENANT IMPROVEMENT OF EXISTING T-MOBILE RETAIL STORE. CONNECTED LOAD< 400A. AFFECTED AREA 2781 SQ FT.B# 17016-10000-08583	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25212	17041-20000-34462	14335 W JOY DR	91331	6	198B149   659	2644027249	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24139	-118.44581	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25213	13041-10000-35885	617 W 7TH ST 3RD FLOOR-CORRIDORS	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	12/24/2013 12:00:00 AM		Permit Expired	01/19/2016 12:00:00 AM	ADDRESS	34.04779	-118.2571	PLAN CHECK FOR T24 ENERGY. 3RD FLOOR. CORRIDORS. 943 SQFT , EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25214	14041-10000-17824	8826 S CENTRAL AVE	90002	9	096A209   212	6043004018	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.9567	-118.25617	PC FOR POWER AND ENERGY.NEW 1-story 5,000 SQ.FT. COIN LAUNDRY BUILDING.BUILDING APPLICATION #:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25215	14041-20000-12725	10530 W VICTORY BLVD	91606	2	177B177    90	2414019012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Expired	09/21/2016 12:00:00 AM	ADDRESS	34.18498	-118.36061	PV2 COMMERCIAL ROOFTOP SOLAR. TOTAL SYSTEM SIZE 30KW AC USING 3 CENTRAL INVERTERS. NONSTANDARD PLAN. INTERCONNECT TO 3PHASE 4W DELTA. 400A SERVICE$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25216	16041-20000-04325	21300 W VICTORY BLVD Ste 600	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.18813	-118.59618	TI for (E) high-rise building commercial office.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25217	17041-10000-31863	1149 S BROADWAY 6TH FLR	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.03859	-118.26015	PC FOR OFFICE TI  FOR TITLE 24 ENERGY ONLY FOR NEW ENCLOSED MODULAR WALL OFFICE AND RECONFIGURATION OF WORK STATIONS AT OPEN OFFICE AREA.INSTALLING NEW LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA 164 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25218	19041-10000-22974	3418 N BLAIR DR	90068	4	159B181    84	5579010013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	Yes	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	06/28/2021 12:00:00 AM	ADDRESS	34.13463	-118.34567	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15  MODULES (PHONO SOLAR PS325M-24 AND 15 MICROINVERTERS (IQ7-60). SYSTEM SIZE IS 4.875KWdc AND 3.75KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25219	18041-10000-02007	11368 W OLYMPIC BLVD	90064	11	123B153    45	4260018002	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM			Reviewed by Supervisor	02/13/2018 12:00:00 AM	ADDRESS	34.03726	-118.44245	PC FOR POWER AND ENERGY FOR NEW ONE STORY OFFICE BUILDING W/3 CAR GARAGE.TOTAL CONNECTED LOAD >400ATOTAL AFFECTED AREA  6100 SQ.FT. B# 18010-10000-00191	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25220	16041-20000-10598	1837 S SAWTELLE BLVD	90025	11	126B149   405	4261021008	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.04291	-118.44567	Plan check for a fire alarm device for a 19-unit apartment building. System consists of (1) FACP, (1) annunciator, and (50) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25221	13041-10000-34523	155 S OXFORD AVE 1-29	90004	10	138B193  1231	5517006027	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Apartment			12/11/2013 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.07206	-118.30822	"FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 5-STORY, 29-UNIT, TYPE III-1HR APT BLDG OVER 2-LEVEL BASEMENT PRKG . (24) TYPE 'A' AND  (5) TYPE 'B' APARTMENTS. SCOPE OF LIGHTING WORK IS APPROXIMATELY 30,972 SQ FT AREA. ""MSB"" OF 400A, 120/240V, 3PH, 4W AND ""MSA"" OF 1000A, 120/240V, 1PH, 3W.building permit under: 07010-20000-03598"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25222	13041-10000-21147	12652 W VILLAGE LANE bldg #7	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #7	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25223	12041-20001-19647	8301 W BEVERLY BLVD	90048	5	138B173   395	5514009027	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.07623	-118.37013	Delta 2 modification to previously approved set of plans to account for conduits penetrating into the methane zone under the building.  All conduits penetrating the methane zone shall be sealed at both ends, and the seals shall be specifically approved for 40% fill.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25224	13041-10000-02025	23813 W SYLVAN ST	91367	3	177B089    85	2033019006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.18456	-118.64509	photovoltaic system for a single family single story dwelling unit. pv1 system. total of 30 modules using sunpower spr-327-ne-wht-d. central inverter sunpower spr-10001f. transformed. total of 9.81kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25225	17041-10000-33582	143 S WETHERLY DR	90048	5	138B169   486	4335008015	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			09/19/2017 12:00:00 AM			PC Info Complete	09/28/2017 12:00:00 AM	ADDRESS	34.07407	-118.38904	New methane system in a new apartment building, 12 devices with a new methane panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25226	18041-10003-03812	14626 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Approved	09/27/2018 12:00:00 AM	ADDRESS	34.22128	-118.45073	DELTA 4 CHANGES TO APPROVED PLANS FOR CHANGING THE SIZE OF THE OCPD TO 450AMP PER MANUFACTURER'S REQUIREMENTS FOR THE COMPRESSOR UNIT.<<<FULL PC FOR POWER AND ENERGY FOR A NEW SHELL BUILDING. SCOPE INCLUDES A NEW 1200A 120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 23014 SQ. FT. B#18010-10000-00386>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25227	17041-20000-16877	851 N ALMA REAL DR	90272	11	126B125    21	4411002901	OS-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.0441	-118.52485	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor/outdoor and em lighting only.  total square footage 2045.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25228	13041-10000-32172	3525 W 3RD ST # 4	90004	10	135B197   146	5518030021	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	PIN	34.06930274	-118.29253852	TI and change of use from beauty parlor to take out restaurant(1152 s.f)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25229	15041-10000-23242	1351 W COLORADO BLVD	90041	14	162A227    84	5691012001	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.13968	-118.19473	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2166.PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-70000-04659	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25230	13041-20001-07303	23956 W EAGLE MOUNTAIN ST	91304	12	193-5A091  53	2017023026	A1-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.22498	-118.64861	(((((SUPP. APPLICATION FOR CHANGE IN PV PANEL. NEW PANEL IS TRINA TSM-250. PC ONLY FOR CHANGE IN PANEL. PERMIT ALREADY ISSUED UNDER ORIRIGINAL APPLICATION. )))PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING, TOTAL SYSTEM SIZE 6.3 KW. USING 26 MODULES, TRANSFORMERLESS INVERTER, NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25231	11041-10000-27352	648-654 S BROADWAY	90014	14	127-5A211  32	5144002023	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.0454	-118.25294	Plan check power only. New two 800A services serving existing commercial building with new switchboards, panels, emergency generator, ckts and equipment. **Additional fees required, verify all fees when Final	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25232	10041-20000-14277	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.05562	-118.27458	Plan check temp power for construction of apartment building. New 600A service and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25233	19041-10000-52671	2747 S GLENDON AVE	90064	5	123B157   493	4255015019	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.03437	-118.42278	1 BATTERY BACK UP INSTALATION TO EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25234	10041-20000-13424	2255 S SEPULVEDA BLVD	90064	5	126B153  1008	4322024029	M2-1VL	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	12/21/2010 12:00:00 AM	ADDRESS	34.03874	-118.43693	energy plan check commercial industrial	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25235	15041-20000-00785	11030 N DE FOE AVE	91331	7	210B161   620	2536004020	R1-1	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Refund in Progress	01/14/2015 12:00:00 AM	ADDRESS	34.27006	-118.41202	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.44kW. Ungrounded system.16 EnPhase M215 microinverters with 16  250W pv modules on a single string.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25236	19041-10000-45772	384 WORLD WAY T.I.-M50	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	03/09/2022 12:00:00 AM		Permit Finaled	07/20/2022 12:00:00 AM	ADDRESS	33.94339	-118.40887	FIRST TIME TENANT IN UNIT #M50 - COMMERCIAL / RETAIL SPACE. INSTALLING PANELS, CIRCUITS & LIGHTS.  PLAN CHECK FOR POWER & ENERGY. ***M50 - HOKKAIDO RAMEN SANTOUKA***	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25237	17041-10000-02831	311 W PACIFIC COAST HWY C	90744	15	036B205   998	7421024014	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	33.79211	-118.26673	T-24, PC FOR ENERGY ONLY. INTERIOR TI OF EXISTING CVS PHARMACY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 16208 SQ. FT. . B##17016-10000-00809	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25238	12041-10000-00162	9301 N TAMPA AVE #106	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI IN AN EXISTING RESTAURANT IN UNIT # 106.  PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25239	19041-20000-47730	13263 N WHEELER AVE UNIT 12	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25240	12041-20000-02391	7924 W 3RD ST	90048	5	138B177   786	5511027025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.07151	-118.36239	REMODEL OF RETAIL ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25241	10041-20000-05799	334 S MAIN ST	90013	9	129A213   129	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	06/25/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	34.04841	-118.24668	Installing disconnect means for 25 horsepower firepump as requested by inspector.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25242	13041-20000-04049	21744 W VENTURA BLVD	91367	3	171B105    39	2168024045	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	PIN	34.16812184	-118.60201842	T24 lighting plan check for  TI - REMODEL STOREFRONT AND ADD ARCHITECTURAL FEATURE TO EXISTING FACADE AND UP GRADE 2 STEELS BEAM PER ENGINEER'S DETAILS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25243	17041-20000-22775	14561 W LYLE ST	91342	7	222B149   511	2505012023	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.30536	-118.45087	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (33) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25244	16041-10000-05078	11300 W NATIONAL BLVD	90066		120B157  1125	4250026022							Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.02602	-118.43153	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW OUTDOOR LIGHTING TO AN (E) RESTAURANT, MCDONALDS. TOTAL SQ. FT. 128.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25245	15041-20000-00333	300 S GRAND AVE conference-rm	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	ti to an existing high rise building.  adding new lighting and new controls to existing panel.  scope of work to be in the conference room LOWER LEVEL.only.  plan check for energy and emergency lighting.  total square footage 3890.LOWER LEVEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25246	17041-20002-09879	12601 W PIERCE ST BLDG 5, 6	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	12-19-2018 Changes to an approved set of plan, changes include addition of performance meter. All changes apply to delta 1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25247	13041-10000-23194	9301 N TAMPA AVE # 67	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI retail space in mall.  Power and energyNote: this should be Title 24 only plan check-remodeling existing retail store ;added power load is less than 100A; CONDUCTORS, PANELBOARDS AND MAIN SWITCH ARE EXISTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25248	19041-10000-50845	757 S ALAMEDA ST BLD 3-Third Flr	90021	14	123A215     2	5146009001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Issued	01/13/2020 12:00:00 AM	ADDRESS	34.0318	-118.23916	Plan check for an addition for an existing fire alarm system. Scope includes (2) power supplied  panels, and (216) fire alarm devices adding on the existing system. BLD: #3, STE. 300, 310, 320, 330, 340, 345, 350, 360, 370, 380, & 390.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25249	19041-10000-49514	2005 W COLORADO BLVD	90041	14	162A223    83	5671009001	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.13942	-118.21056	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25250	13041-10001-35832	5858 N SHOUP AVE POOL BLDG	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			Corrections Issued	09/09/2015 12:00:00 AM	ADDRESS	34.17705	-118.6144	LOADS AND PANELBOARDS REMOVED FROM MSA AND NOW SUPPLIED FROM THE POOL BUILDINGDISTRIBUTION BOARD. NO CHANGES TO EXISTING OTHER EQUIPMENT((((((((PLAN CHECK FOR POWER AND ENERGY FOR NEW POOL BUILDING.   (4 OF 4 ) ALL FEES FOR ENERGY ARE UNDER APPLICATION # 13041-10000-35818.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25251	19041-10000-49280	11036 W MOORPARK ST	91602	4	165B173   340	2423013110	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	12/21/2020 12:00:00 AM	ADDRESS	34.15006	-118.37183	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS ONE NEW FIRE ALARM PANEL, SIX POWER SUPPLIES, ONE ANNUCIATOR, AND 267 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25252	14041-20012-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/12/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	33.95605	-118.38499	PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED DELTA 15 CHANGES ONLY. REPLACEMENT AND ADDING LANDSCAPE LED LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25253	17041-10000-16807	20416 W STAGG ST	91306	3	189B109  1105	2114001054	(T)(Q)RD6-1, R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.21059	-118.57822	Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system.  Total system size = 6.12 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25254	18041-10000-00991	6729 N VARIEL AVE	91303	3	180B105    22	2148030036	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	34.19282	-118.59304	T-24, PC FOR ENERGY ONLY. REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 82100 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25255	16041-20001-31193	5071 N SHIRLEY AVE	91356	3	171B117   404	2175031001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.16334	-118.55727	EXPEDITE PER APPLICANT REQUEST.PV1EXPASION TO AN EXISTING PV SYSTEM.INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED TO MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25256	19041-20000-10391	14241 W VENTURA BLVD	91423	4	165B153   330	2265019006	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	08/25/2022 12:00:00 AM		Permit Finaled	03/20/2023 12:00:00 AM	ADDRESS	34.15025	-118.44356	TI to an existing commercial bulding two story. service upgrade to 1200 amps. New lighting and power loads  plan check for power and energy. Total square footage = 27745 sfbuilding application number 18014-10000-04012	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25257	14041-20000-19113	8900 N ENFIELD AVE	91325	12	195B129   225	2768003012	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	08/17/2014 12:00:00 AM	ADDRESS	34.23215	-118.5243	pv1 single family dwelling. total system size 6.8kw ac using 2 central transformerless inverters. using standard plan. uses power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25258	10041-10000-25829	3970 W MARTIN LUTHER KING, JR BLVD UNIT#2	90008	10	117B181   606	5032007022	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	12/30/2010 12:00:00 AM	ADDRESS	34.015	-118.34242	REPLACE/INSTALL LIGHTS, SWITCHES,  TO AN EXISTING CIRCUITS. EPC IS FOR ENERGY, T24 & EMERGENCY LIGHTS. UNIT#2 OF 4 (PERMIT WAS PULLED UNDER# 10041-10000-23248)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25259	13041-10001-22043	7600 S AVALON BLVD	90001	9	099B205    94	6023017900	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.02	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	PIN	33.97099935	-118.26484019	"EXPEDITED PLAN CHECK PER APPLICANT REQUEST"" PV2. ROOF MOUNTED PHOTOVOLTAIC SYSTEM. 8.637 kW. TRANSFORMERLESS INVERTER."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25260	13041-20001-35142	4960 N PALO DR	91356	3	168B117    91	2175006036	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM			PC Approved	12/21/2013 12:00:00 AM	ADDRESS	34.15957	-118.55497	((Expedite fees)) PV1 CENTRAL INVERTER. 5 STRINGS FOR 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25261	16041-10000-45088	1940 S HOOVER ST	90007	1	126A201   239	5135014043	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.03838	-118.28383	PC for energy only. Outdoor title 24. Remove HID fixture and replace with new LED fixtures. Area: 5,435.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25262	18041-30000-07056	10201 W PICO BLVD Craft Bld.-4th floor	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Info Complete	04/17/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	Plan check for power and energy for T.I. office space on 4th floor (e) 5-story office building. Distribution rat\ted 600A with associated load. Total area: 10,228 sq ft.B#18016-30000-03517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25263	16041-20000-24621	6515 S KANSAS AVE	90044	8	105B197  1639	6014006011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Expired	09/12/2018 12:00:00 AM	ADDRESS	33.98002	-118.29381	Plan check for PV roof mounted system. System size: 3.8kW with 15 modules with 1 inverter (3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25264	19041-20000-15120	338 N MARIPOSA AVE	90004	13	138B197    94	5520024009	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Apartment			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	04/29/2021 12:00:00 AM	ADDRESS	34.07745	-118.29927	PC FOR NEW FIRE ALARM SYSTEM OF 75 DEVICES AND A FIRE ALARM PANEL IN A NEW 4 STORY 14 UNIT APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25265	15041-20001-10047	12452 W OSPREY LANE #3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	Supplemental application for expedite fees.Installation of new roof mounted solar PV array on 3 unit apartment building (triplex).  Each unit panel is fed by a seperate inverter (3 inverters total).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25266	16041-10002-40450	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			Corrections Issued	06/19/2018 12:00:00 AM	ADDRESS	33.97902	-118.43558	PLAN CHECH FOR TITLE 24 ONLY OR FOR REPLACEMENT FOR STAIRCASE LIGHTING LIGHTING FIXTURES - TOTAL AFFECTED AREA = 2070 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25267	16041-20000-28188	12148 W VAN NUYS BLVD	91342	7	213B165   123	2531026006	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.28384	-118.39738	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25268	18041-20000-05343	10534 W SANTA MONICA BLVD 1-9	90025	5	132B157  1071	4317004016	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.05456	-118.42769	new fire alarm system 107 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25269	18041-20000-24345	252 N HOOVER ST	90004	13	139-5A201 224	5156003004	C2-1	Central	Westlake	Rampart Village	YES	2086.10	Electrical	Electrical	Apartment			06/29/2018 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	12/09/2022 12:00:00 AM	ADDRESS	34.07587	-118.283	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new construction.  Plan check for power and energy.  Note: Building permit under 18010-10000-02884	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25270	17041-10000-00492	776 W 1ST ST	90731	15	018B197  1078	7451004017	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Expired	10/10/2023 12:00:00 AM	ADDRESS	33.74341	-118.29398	PV2 roof mounted solar sytem installation. Duplex residence. Central inverter rated at 6.6 KW and 25 solar modules, load center included rated at 125 Amps.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25271	16041-20000-18554	5419 N TAMPA AVE	91356	3	174B117   599	2163014020	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.16954	-118.5536	PV1.  Install 11.77 kW roof mounted PV system.  (34) 327 W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25272	19041-10000-00736	2121 S AVENUE OF THE STARS #26-#27	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.05554	-118.41342	T-24 FOR FL 26 & 27 OF HIGH RISE OFFICE BUILDING. LIGHTING FOR WELLNESS ROOM ONLY, TOTAL CONDITIONED SQFT = 367	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25273	19041-30000-15337	601 S FIGUEROA ST Suite 3650	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is an existing suite on the 36th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 3,650 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25274	19041-20001-52431	6801 W SANTA MONICA BLVD	90038	4	144B185   725	5532019016	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	11/05/2020 12:00:00 AM	ADDRESS	34.09088	-118.33885	Expedited plan check fee.PV3.  Install 129.56 kW DC roof mounted PV system.  (328) modules with 100 kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25275	16041-20000-05738	9208 N ALDEA AVE	91325	12	198B133   443	2692007006	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.23778	-118.50966	Plan check for PV roof mounted system. System size: 7.60kW with 30 modules and 1 inverter(7.6kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25276	09041-10001-06331	315 W 5TH ST	90013	14	129A211    56	5149026001	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			02/04/2010 12:00:00 AM			PC Approved	02/04/2010 12:00:00 AM	ADDRESS	34.04847	-118.25108	RELOCATE  THE EMERGENCY GENERATOR TO THE ROOF OF THE SECOND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25277	18041-10000-41203	7318 W SUNSET BLVD	90046	4	147B181   661	5550018019	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.09784	-118.35022	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25278	17041-30000-18206	801 S FIGUEROA ST STE 450	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only in existing sapce T.I. Total area: 1,415 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25279	18041-20001-43768	5555 W MELROSE AVE Bldg 213	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			PC Approved	04/30/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	04-30-2019 Changes to an approved set of plan, Changes include increase fuse rating to 200A, all changes has been clouded as delta 2. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25280	13041-10000-28637	738 S SAN PEDRO ST	90021	14	126A211   221	5146033042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	PIN	34.03963021	-118.24742512	Remove HID light fixtures and replace w/ fluorescent fixtures.  Title 24 plan check only, permit to be issued at EPC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25281	19041-10000-29534	15914 S ORCHARD AVE	90247	15	069B197   137	6120014024	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	33.88673	-118.2881	E-PLAN- INSTALLATION OF 2 NEW ESS(TESLA POWER WALLS) ON EXISTING PV1 SYSTEM AND 200A SERVICE - MAIN PANEL DERATION TO 125A - LOAD CALCULATIONS HAVE BEEN ATTACHED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25282	13041-10000-09069	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.06488	-118.47066	renovation OF SMALL SPACES IN A SCHOOL. MAINLY OFFICES, CLOSETS AND RESTROOMS. PC FOR T24 ENERGY ONLY. TOTAL AREA 500 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25283	16041-20001-10152	9101 N RESEDA BLVD	91324	12	198B125   262	2763034003	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.23593	-118.53628	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA B.  THIS IS PLAN CHECK ONLY.T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 2352 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25284	16041-20001-02663	1575 N GOWER ST	90028	13	148-5A189 330	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.09907	-118.32257	05/11/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. Title 24 Compliance Forms have been updated to reflect all lighting changes. Changes have been made to the lighting floor plan and the power plan. CHANGE OF ADDRESS HAS ALSO BEEN MADE*****Previous Work Description*****Plan check for 1st time tenant for power and energy Tender Fender-Hollywood 2 story office building existing service and generator. Total area: 21,379 sq ft.Note: Building plan check is under 16016-10000-01289Note: Electrical Core and shell have been done on Application # 13041-20000-33082	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25285	15041-10000-22105	1806 S CARMONA AVE	90019	10	126B177   903	5064010010	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.04113	-118.36069	PV 2. ROOF MOUNTED 3.64 KW ROOF MOUNTED PV SYSTEM. INTERCONNECTED TO MAIN PANEL.(14) MODULES   KYOCERA #KU2606XPA(1) INVERTER ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25286	14041-10000-13352	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	Plan check for energy only to convert an existing open office into a conference room.  Convert two individual offices into an open office.TI for dodger stadium	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25287	19041-30000-37248	11911 W SAN VICENTE BLVD Ste. 235	90049	11	129B145    78	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.05295	-118.47002	PC FOR ENERGY ONLY TO A TENANT IMPROVEMENT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1296.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25288	18041-20000-40449	9870 N SAN FERNANDO ROAD 110-113	91331	7	201B165    56	2537015042	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.25001	-118.40419	TI to an existing commercial building - change of use to nursery.  New distribution and wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25289	17041-10000-18532	2029 S CENTURY PARK EAST 7TH FL. LB-FLOOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR TITLE 24 ENERGY ONLY FOR 7TH FLOOR ELEVATOR LOBBY. TOTAL AFFECTED AREA 295 SQ.FTINSTALLING NEW LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25290	17041-10000-07212	6700 S MAIN ST	90003	9	102B205   165	6011003065	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.97856	-118.27375	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 56200 SQ FT.  INDOOR+OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25291	13041-10000-02444	3801 N EAGLE ROCK BLVD 1-9	90065	13	154-5A217 334	5460001043	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Apartment			02/20/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.11866	-118.23238	New 3 story town house with 9 units (BUILDING A).  New 600 Amp service, switchboard, and panels.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25292	17041-20000-43920	12907 W SUNSET BLVD	90049	11	132B137   407	4406009015	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			Reviewed by Supervisor	12/13/2017 12:00:00 AM	ADDRESS	34.05724	-118.49153	Plan check for AC coupled battery backup system for SFD. Existing pv system on site.(1) Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25293	13041-20001-36076	7349 N RUTHERFORD HILL DR	91304	12	186B089   522	2027043014	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	PIN	34.20459046	-118.65283254	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTALSYSTEM SIZE 6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25294	14041-10004-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	33.95605	-118.38499	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS. CHANGE TO SERVICE IS NOW SINGLE 5000A SERVICE POINT AND ALL BUILDINGS WILL TIE INTO. THIS PERMIT AND CHANGE ONLY COVERS THIS PORTION OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25295	11041-10000-01055	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.0965	-118.30717	New generator and transfer switch for an existing office building.  EPC for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25296	18041-10000-41670	1387 W 35TH ST	90007	8	120B197   682	5040003024	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.02471	-118.29999	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25297	12041-10000-24533	12300 W GREENE AVE	90066	11	108B157   667	4232026015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	33.99272	-118.42098	PV1 Plan check for installation of a 4.16KW photovoltaic system using Enphase M215 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25298	19041-10000-37759	5114 N STERN AVE	91423	4	171B153   586	2269004002	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	34.16361	-118.4344	$0.00 fee due to senate bill 1222 and 1414[EPLAN] REVISIONS TO 19041-10000-24724 CHANGES TO SINGLE LINE -REMOVAL OF EQUIPMENT - CHANGES WERE CLOUDED UNDER DELTA E	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25299	16041-20000-30654	11221 N RAVENNA LANE	91326	12	210B109   498	2701051068	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Expired	05/10/2017 12:00:00 AM	ADDRESS	34.27518	-118.58496	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.2 KW. (SUBMITTED PER APPLICANTS REQUEST)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25300	17041-20001-22157	18537 W STRATHERN ST	91335	12	189B125   271	2103009***	(Q)RD6-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.21576	-118.53751	EXEPDITE PER APPLICANT REQUEST.Plan check for new roof-mounted solar pv system on SFD. There is an existing 3.6kW pv system.New system size is 3kW ungrounded w/(10) 300W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25301	13041-20000-06699	10635 N WOODMAN AVE	91345	7	207B149   430	2648004045	(T)RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.26343	-118.45534	New two story multipurpose building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25302	13041-10000-17881	11677 W SAN VICENTE BLVD #315	90049	11	132B145   497	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.05404	-118.46492	permit to be pulled at EPC counter only. PC for energy only. TI for existing restaurant (bakery).REMOVE EXISTING PARTITION WALL AND BUILD NEW NON BEARING PARTITION; REPLACE SERVICE STATION IN (E) RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25303	14041-20000-31393	9694 W OAK PASS ROAD	90210	5	153B157   128	4384007023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.11636	-118.42855	PV1 SFD. TOTAL SYSTEM SIZE 22.5KW AC USING MICROINVERTERSYSTEM. USING ENPHASE M250. NONSTANDARD PLAN.Note: Permit is $0.00 due to Senate Bill 1222 from 2012.Note: the solar PV installation shall comply with FPB requirement No. 96  or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25304	16041-20000-02255	11831 W FOLKSTONE LANE	90077	5	153B141   114	4378037079	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Expired	03/06/2018 12:00:00 AM	ADDRESS	34.1153	-118.47509	Install a solar array on a SFD. System size: 12.5 kWac, ungrounded system. (50) EnPhase M250 microinverters with (50) 285W pv modules.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25305	12041-10000-26555	21021 W ERWIN ST	91367	3	177B109     7	2149004007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			11/08/2012 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.18304	-118.59175	NEW 5 STORY MULTI-FAMILY APARTMENT BUILDING (8 TYPICAL UNITS). THREE 3000A SERVICE SUPPLYING BUILDING LOCATED AT ATTACHED PARKING GARAGE STRUCTURE. PARKING STRUCTURE AND SWIMMING POOLS WILL BE DONE UNDER SEPERATE APPLLICATION. FIRE ALARM SYSTEM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25306	18041-10000-12961	8900 N DE SOTO AVE BLDG: 113	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.23162	-118.58832	Full plan check for power and energy on existing building, install (1) 225A bus panel with some circuits, load < 200A;  (1) 45kVA transformer., total area under SOW: 280sq.ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25307	14041-20002-12014	12650 W SANDHILL LANE Unit 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	33.9774	-118.4142	CLOUDED CHANGES. CHANGE IN ROOF LAYOUT AND NO MONITORING UNIT. RESTAMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25308	13041-10000-06374	7333 W WORLD WAY	90045	11	090B161    67	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	PIN	33.94534804	-118.41786236	T24 FOR OFFICE SPACE, REMODELING EXISTING ROOM GENERAL LIGHTING. 228 SQRFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25309	17041-20000-22150	22115 W CALIFA ST	91367	3	177B101   279	2146015021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.17776	-118.6082	Plan check for roof-mounted solar pv system with an AC coupled battery backup system, SFD.6.6kW ungrounded system. (23) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25310	14041-10000-27203	4618 W FOUNTAIN AVE	90029	13	147B197  1113	5542018032	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.09536	-118.2902	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT.  PHARMACY. 520 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25311	10041-10000-06654	1845 S PONTIUS AVE	90025	5	126B153   198	4323026015	M2-1	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.04443	-118.44248	TENANT IMPROVEMENTS TO EXISTING 10,000 SF SINGLE STORY STRUCTURE - 1,200 SF 2ND STORY ADDITION  ;  94SF 1ST STORY SHED ADDITION AND 909SF CARPORT ADDITION. THIS WILL BECOME A NEW ANIMAL KENNEL FACILITY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25312	10041-20000-21868	17750 W SHERMAN WAY #200 &-#202	91335	3	183B129   186	2121018026	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.20085	-118.52052	T.I. to existing building of the 2nd floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25313	17041-20000-14863	6041 W CADILLAC AVE	90034	10	126B173   862	5066003021	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Issued	12/14/2017 12:00:00 AM	ADDRESS	34.03806	-118.37594	New outdoor lighting installed under solar pv carport located on roof of commercial parking garage. 50,886sqft. Building permit application #17016-10000-11539.Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25314	19041-10001-30236	515 N BEACON ST	90731	15	018B201   184	7449007900	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro	YES	2962.10	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Closed	06/09/2020 12:00:00 AM	ADDRESS	33.74742	-118.28054	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES UNDER DELTA 2. CHANGES INCLUDE REVSING SERVICE FROM UNDERGROUND TO OVERHEAD, REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, ADDING A CENTRAL INVERTER INSTEAD OF USING BATTERY PACKS, AND REVSING FLOOR PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25315	16041-10003-38115	21425 W VANOWEN ST	91303	3	183B105   951	2138011023	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM			PC Approved	03/23/2018 12:00:00 AM	ADDRESS	34.19399	-118.59858	SUPP. FOR CHNGES TO PAGE E0.03A THAT ARE PART OF 10002 SUPP. CHANGE TO REFLECT DELTA 4 ONLY. PERMIT PULLED UNDER 10002. THIS IS PLANCHECK ONLY!Changes to an approved set of plans. All changes are clouded under delta 4. Changes include adding/removing circuits, revising load calculations, relocating receptacles/lights on the floor plans, and revising title 24 controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25316	18041-10000-35709	125 N LAYTON DR	90049	11	135B145   164	4429026005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.06912	-118.4709	NEW 13,000 SQR FT, 3 STORY SINGLE FAMILY HOUSE WITH A 800 AMP SERVICE.PLAN CHECK ONLY. BLDG COMBO PERMIT: 16010-30000-01673	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25317	11041-10000-27109	17947 W CHATSWORTH ST L2	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			12/20/2011 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	06/15/2012 12:00:00 AM	ADDRESS	34.265	-118.52509	New restaurant. Service is existing, new panels and ckts. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25318	18041-10000-31517	4672 E YORK BLVD	90041	1	156A223   136	5474018005	RD3-1, [Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.02	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.12269	-118.21421	FULL PLAN CHECK FOR - NEW 2-STORY RETAIL BLDG; RESTAURANT ON THE 1ST FLOOR AND OFFICE ON THE 2ND FLOOR- ALL FOR ONE TENANTBUILDING PERMIT # 16010-10000-03043	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25319	14041-20000-33661	16613 W NORDHOFF ST	91343	12	198B137   974	2687024007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.23587	-118.49438	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZE 10 KW INTERCONNECTED WITH MAIN SERVICE PANNEL.(30) SUNPOWER E327 MODULES(2) AURORA PVI-5000 TRANSFORMERLESS INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25320	15041-20000-34857	8391 N TOPANGA CANYON BLVD	91304	12	192B101   471	2010023041	C2-1L, P-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.22185	-118.60632	TI to existing build, used to be Med/Restaurant convert to optometry. Scope of work include exam rooms but no invasive procedure. All electrical equipment are existing. PC for Energy. Total area: 3,045 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25321	10041-10000-22268	225 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04942	-118.22625	Solar voltaic system installed on the roof of the building.  Consists of 13 modules, 13 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25322	13041-10000-17543	1600 N VINE ST	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Closed	12/26/2013 12:00:00 AM	ADDRESS	34.1	-118.32647	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING ON A FITNESS CENTER IN A HIGH RISE.  EXPRESS PERMIT #  WILL BE THE SAME AS P.C APPLICATION #	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25323	13041-20000-03710	18310 W OXNARD ST	91356	3	177B125   690	2157002131	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.18003	-118.53125	Plan check for energy only. Warehouse lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25324	17041-20002-43680	7957 N SANGAMON AVE	91352	2	189B181   194	2403013006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.21599	-118.34739	"Revision to approved set and change of project work description to ""PV1.  Install 5.85 kW roof mounted grid tied PV system.""  Energy storage component of project removed.  Fees $0.00 due to California Senate Bill 1222"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25325	11041-20000-02480	7325 N SEPULVEDA BLVD 1-40	91406	6	186B145   638	2222021010	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	05/06/2011 12:00:00 AM		Issued	05/06/2011 12:00:00 AM	PIN	34.20374624	-118.46691136	Plan check for new 800 amp service, switchboards, panels, and branch circuits.  No change in lighting.  Per electrical plan supervisor, the 30 amp feeder disconnecting means are permitted.  Plan check for power only.Note: Some electrical panels permit under 11041-20000-01481	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25326	13041-10000-32032	20705 W CAMPANIA LANE	91326	12	213B109   543	2701070050	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.28031	-118.58414	PV1.  Install 7.00 kW DC roof-mounted PV system, interconnect with main service panel.  28 modules: Renesola JC250M-24/BB.  Transformerless inverter: SolarEdge SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25327	16041-10000-16069	5363 N BALBOA BLVD Suite B	91316	5	171B133    38	2258027016	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Issued	01/31/2017 12:00:00 AM	ADDRESS	34.16893	-118.50129	Plan check for power and Title-24.  Total area = 1,097 sq. ft.     T.I. to existing single story medical office.  New 200 A panel with lighting and receptacles in medical center patient care areas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25328	11041-20000-17675	2407 N CARMAN CREST DR	90068	4	153B181   265	5572009014	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2011 12:00:00 AM			Corrections Issued	09/01/2011 12:00:00 AM	ADDRESS	34.11424	-118.34618	11.61 kw PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25329	10041-20000-04169	515 S FIGUEROA ST #1230	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	04/26/2010 12:00:00 AM	ADDRESS	34.05199	-118.25764	ti energy plan check # 1230	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25330	19041-20000-42541	2465 E HUNTER ST	90021	14	121-5A219  62	5168031025	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	07/06/2020 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.02771	-118.22768	Plan check for Title 24 Energy only, new lighting. Total area: 3280 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25331	19041-20000-10306	1805 S MESA ST LOT 12	90731	15	012B201   787	7456029038		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	09/01/2020 12:00:00 AM	ADDRESS	33.72769	-118.28613	INSTALLATION OF A 3.02KW DC/2.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (9) SUNPOWER 335 BLK PV MODULES WITH INTEGRATED MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25332	15041-10001-24068	1500 W PACIFIC COAST HWY Bldg I	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION OF 41 DEVICES AND 1 POWER SUPPLIES, FOR FUTURE ADA REQUIREMENT.  (((NEW FA SYSTEM FOR A New 3-story, 15 unit apartment with garage, 43 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25333	13041-20000-30400	5900 W WILSHIRE BLVD 5th floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Change to lights in an existing low rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25334	14041-10000-23333	22816 W VANOWEN ST	91307	12	180B097    43	2038040028	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.19345	-118.6243	TENANT IMPROVEMENT INSIDE A JERSEY MIKE'S RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25335	18041-20000-08529	13037 W LOUVRE ST	91331	7	213B161   954	2533005024	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.27656	-118.41672	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (10) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25336	16041-10000-11284	2101 E PACIFIC COAST HWY WHCU	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	11/30/2017 12:00:00 AM		Issued	11/30/2017 12:00:00 AM	ADDRESS	33.79173	-118.23549	PC FOR POWER.MEDIUM VOLTAGE. INSTALLING ONE 3750KVA TRANSFORMER ALONG WITH 2250HP STAGE CHARGE PUMP AND 2 100 HP HYDROGEN BOOSTER COMPRESSOR MOTORS ALONG WITH 4 LUBRICATORS FOR TESORO REFINERY. WHCU PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25337	19041-10000-14318	5651 W 96TH ST	90045	11	093B169   132	4125021025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	33.94947	-118.38017	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25338	19041-20000-48603	5900 W WILSHIRE BLVD 11TH FLR	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			PC Info Complete	11/25/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	T24 ENERGY ONLY PLAN CHECK FOR LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 6403 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25339	17041-10000-10159	1145 S GAYLEY AVE	90024	5	132B149   118	4363023033	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Info Complete	04/06/2017 12:00:00 AM	ADDRESS	34.05935	-118.44602	Plan check for Title 24 for outdoor lighting building Entrance non-sales canopies. Total area: 128 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25340	17041-10001-05715	14006 W RIVERSIDE DR STE 245A	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. USE OF CENTRAL INVERTER AND SOME OTHER MINOR NOTES. THIS APPLICATION IS PLAN CHECK ONLY. PERMIT TO BE ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25341	12041-20000-02053	1112 W MARTIN LUTHER KING, JR BLVD	90037	9	114B197   250	5020017003	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.01067	-118.29463	T24 lighting plan check for remodeled office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25342	16041-20000-17032	1108 S LOS ANGELES ST unit 102	90015	14	126A209   262	5145021022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.03808	-118.25716	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAKL SQUARE FOOTAGE 2120.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25343	19041-10002-08261	3203 N CANYON LAKE DR	90068	4	156B185    16	5577036013	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.12776	-118.32732	EXPEDITENEW 12.6KW ROOF MOUNTED PV SYSTEM WITH 40 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25344	16041-10001-08109	1740 S WESTMORELAND BLVD	90006	10	126B193   606	5074019004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM			Reviewed by Supervisor	03/21/2016 12:00:00 AM	ADDRESS	34.04162	-118.30641	EXPEDITE PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDNENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.75KWdc / 5.375KWac. (25)MODULES-SILFAB SOLAR SLA-M270(25)MICROINVERTERS-ENPHASE M215-60-2LL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25345	11041-20000-23246	10844 W CHANDLER BLVD	91601	4	171B173   111	2416008001	MR1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10, 1253.20	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Closed	11/16/2011 12:00:00 AM	ADDRESS	34.1684	-118.36728	PLAN CHECK T24 ENERGY FOR TI WHOLESALE BAKERY FROM. PERMIT FOR NEW LIGHT FIXTURES ON EXISTING CKTS AND NEW BRANCH CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25346	14041-10000-15114	5510 S LINCOLN BLVD	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	33.97299	-118.43051	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. NO CHANGE IN OCCUPANCY. OFFICES. SUITE 410. 5568 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25347	17041-10000-02310	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.13829	-118.34154	FULL PLAN CHECK RENOVATION OF NORTH CLUBHOUSE. 1 OF 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25348	18041-10000-37151	20929 W VENTURA BLVD UNIT 34	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	new panel and ckts in exisiting retail spacePLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25349	14041-10000-22834	1529 E PLEASANT AVE 1-3	90033	14	129A221    57	5174021035	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Apartment			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.04894	-118.2212	NEW FIRE ALARM SYSTEM FOR 3 STORY 3 UNIT APARTMENT BUILDING.  TOTAL NUMBER OF DEVICES = 9	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25350	19041-20003-02298	13115 N TELFAIR AVE	91342	7	222B141   327	2604002050	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Approved	09/06/2019 12:00:00 AM	ADDRESS	34.30778	-118.47865	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET ON SINGLE LINE AND ADDITION OF SPEC SHEETS. UPDATE MADE TO AVAILABLE FAULT CURRENT VALUES. CLOUDED DELTA 2 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25351	19041-10000-41540	1475 N BEL-AIR ROAD	90077	5	147B149   458	4370018026	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.09756	-118.44635	Power plan check for a new 600-Amp service located in a new single family dwelling unit. Scope includes (1) 600-amp service, (5) equipment, (4) main panels and other ckts. Note. Most of the permit fee is paid under combination permit, (15010-20000-03794)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25352	16041-10000-30353	907 E 3RD ST	90012	14	129A215   276	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	PIN	34.04608986	-118.23489239	RE CHECK FOR LOST SET OF PLANS. ((PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT WITH 400AMP FEEDER, FEEDING FROM A 1200AMP SWITCHBOARD. TOTAL AREA 3470 SQ FT.B# 15014-10000-05332)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25353	16041-10000-28546	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	INSTALLATION OF NEW FIRE ALARM SYSTEM WITH FOR 366 FIRE ALARM DEVICES AND 12 FIRE ALRM PANELS . FOR A 5-STORY PLUS 3 LEVEL UNDERGROUND  MACY'S STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25354	16041-20000-41466	1447 N MARTEL AVE SLS#1	90046		147B181  1153	5550021013							Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Plans on Hold	12/02/2016 12:00:00 AM	ADDRESS	34.09728	-118.35102	New 4-story single family dwelling with subterranean attached garage.  Small lot subdivision.  Collective service for (6) new SFDs on same lot.  Plan check for power and energy.  Service equipment, house panel, and energy fees charged on unit #1.  Building permit filed under 16010-10000-02540 et al	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25355	19041-10000-00976	1236 N STRADELLA ROAD	90077	5	147B149   572	4370007016	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.09482	-118.45495	PV1, NEW ROOF MOUNTED SOLAR SYSTEM TO A SINGLE FAMILY DWELLING USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (1)10KWAC INVERTER, (37) MODULES AND (37) OPTIMIZERS. TOTAL SYSTEM SIZE 13.32 KWDC/ 10KWAC. MAIN OCPD REMAINS AT 200APANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25356	12041-10000-08461	1750 N VINE ST	90028	13	148-5A189   4	5546030028	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	12/20/2012 12:00:00 AM	ADDRESS	34.10311	-118.32649	REPLACING 3 OLD EXISTING FIRE ALARM PANELS WITH NEW ONES. ALL EXISTING WIRING & DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25357	10041-10000-11433	1100 S SAN PEDRO ST A-14FRONT-A-14REAR	90015	9	124-5A211 343	5132011***	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	11/17/2010 12:00:00 AM	ADDRESS	34.03515	-118.25194	TENANT IMPROVEMENT IN EACH OF TWO RETAIL CLOTHING STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25358	18041-10000-04238	2432 S PENMAR AVE	90291	11	108B149   449	4236004007	RD1.5-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Apartment			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	33.99404	-118.45027	NEW FIRE ALARM SYSTEM TO AN EXISTING BUILDING. SCOPE OF WORK INCLUDES A NEW FIRE ALARM PANEL AND (43) FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25359	12041-20000-13609	7012 N OWENSMOUTH AVE	91303	3	183B105   617	2138008010	P-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM			PC Info Complete	06/18/2012 12:00:00 AM	ADDRESS	34.19776	-118.60139	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25360	18041-20000-38953	1989 W NORWALK AVE	90041	14	160-5A223 331	5685008040	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.13265	-118.21117	Plan check for a PV1 roof-mounted PV system. System size is 3.9 kWdc/3.8 kWac and consists of (1) inverter, (12) modules, (2) Tesla PowerWalls, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25361	15041-20001-32710	508 N JUNE ST	90004	4	141B185   957	5523001024	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/23/2015 12:00:00 AM	ADDRESS	34.08059	-118.33402	Expedited per customer request.PV1. Install roof mounted PV system sized 7 kW. Interconnected with main service panel.(24) LG Monox 315 Modules(1) SMA 7.0 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25362	19041-20000-52486	10960 W WILSHIRE BLVD STE 900-950	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	10/02/2020 12:00:00 AM	ADDRESS	34.058	-118.44597	T24 PLAN CHECK, ENERGY ONLY, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 13218 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25363	19041-30000-23165	11990 W SAN VICENTE BLVD 2ND FLR	90049	11	129B141   244	4265007050	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.05206	-118.47239	PC ENERGY ONLY FOR CORRIDOR 2ND FLOOR. AREA OF SCOPE 790SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25364	10041-20002-25719	4600 W SPERRY ST	90039	4	165B201   177	5593007004	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Closed	04/18/2012 12:00:00 AM	ADDRESS	34.14823	-118.27596	Changes from previous approved plans (10041-20000-25719).  Changes include replace 15KVA transformer,  additional of a combiner box.Note: Permit to change contractor from previously approved plans issued under 10041-20002-25719.*****New roof mounted P.V. system for commercial building. *****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25365	16041-10001-00936	5549 E ALLAN ST	90032	14	141A239    47	5291020020	PF-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	34.08119	-118.16063	01/28/16PV1. Changes to an approved set. Changes include relocating modules on the roof layout. No other changes made. Note: permit paid under PCIS#16041-10001-00936((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.3KWac.(20)MODULES-SE-F270(20)MICROINVERTERS-ENPHASE ENERGY M215-60-2LL-S2X	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25366	19041-20000-49194	19601 W MAYALL ST	91324	12	204B117   431	2726010006	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Issued	11/27/2019 12:00:00 AM	ADDRESS	34.25374	-118.5608	PV1 PLAN CHECK FOR NEW PV SYSTEM, SYSTEM SIZIE 7.15 KW DC/6.617 KW AC. SCOPE OF WORK CONSISTS OF (22) PV MODULES WITH MICROINVERTERS AND A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25367	16041-10000-01096	1605 N CHEROKEE AVE 1-66	90028	13	148-5A185 268	5547014***	PF-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.09994	-118.3353	NEW FIRE ALARM SYSTEM 201 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25368	15041-20000-02921	11813 W VALERIO ST	91605	2	186B169   659	2317017010	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			01/30/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.20495	-118.39087	PV2. Install roof mounted PV system sized 3.0 kW. Interconnected with main service panel.(10) Kyocera KU255 Modules(1) PVI 3.0 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25369	19041-20003-10404	16909 W ARMSTEAD ST	91344	12	213B133   224	2610009004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.28259	-118.50024	$0 FEE DUE TO SB 1212 AND AB 1414PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25370	18041-10000-20101	11111 W SANTA MONICA BLVD #800	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	INTERIOR OFFICE T.I. OF 6,570 SF.PLAN CHECK IS FOR TITLE 24 AND 1 EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25371	13041-10000-05762	17830 W BAHAMA ST	91325	12	195B129   218	2768030002	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.23264	-118.52259	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 8.7757 KW. 2 INVERTERS AND TRANSFORMERLESS. [INVERTER: SOLAR EDGE SE3800A-US] [SOLAR MODULE: TRINASOLAR TSM-245 PC/PA05]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25372	11041-20000-03648	6222 W WILSHIRE BLVD #650	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Finaled	04/06/2011 12:00:00 AM	ADDRESS	34.06309	-118.36418	T.I. to existing building.  Install general/emergency lighting partial of 6th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25373	15041-20000-24184	8842 W FOOTHILL BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.26086	-118.32514	Plan check for power and Title-24 (energy).  Total area = 5,249 sq. ft. (indoor) + 1,000 sq. ft. (outdoor)  Core and shell work on existing commercial space.  Two new 480V 3ph-3w services (ungrounded system), new distribution panels, and associated subpanels.  New lighting, HVAC, and other misc loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25374	13041-20000-28296	10901 W VENTURA BLVD	91604	2	162B173   525	2366022022	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM			PC Approved	11/04/2013 12:00:00 AM	ADDRESS	34.14011	-118.368	PC FOR T24 ENERGY ONLY. NEW LIGHTING FOR SMALL Sushi bar INSIDE LEASE SPACE IN RALPHS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25375	12041-20000-26044	5445 N BALBOA BLVD	91316	5	174B133   791	2258027015	(Q)C4-1VLD, (Q)CR-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Closed	12/17/2012 12:00:00 AM	ADDRESS	34.16983	-118.50129	Change to lighting in the 2nd story restrooms.  Plan check only for Energy.  Contractor is doing other work in the building that is greater than 400 amps, THIS WORK MAY REQUIRE FULL PLAN CHECK SUBJECT TO REQUEST BY INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25376	16041-10000-02778	120 N ROBERTSON BLVD PLAZA-NO	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.07585	-118.38356	TI on (E) office building. PC for energy only, total area 6000sq. ft. All electrical equipment are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25377	17041-10000-20012	479 S DALEHURST AVE	90024	5	138B153   279	4359004031	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.07283	-118.43514	Installation of new solar PV system on existing single family dwelling.  Remove inverters from previous solar system and reconnect existing modules to new DC/DC optimizers and one new inverter with 2 new DC coupled batteries.  Total system size = 7.6 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25378	15041-20000-16495	320 S HAMPTON DR (SITE)	90291	11	111B141   717	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	33.99612	-118.47637	Title 24 plan check only.  Total area = 36,274 sq. ft.  Installation of 5 new panels (<400 A) and new outdoor lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25379	10041-10000-11815	6300 W WILSHIRE BLVD 21st &22nd-FLOORS	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	34.06319	-118.36591	REMODELING OF OFFICES ON THE 21st AND 22nd floors	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25380	18041-10000-49193	2328 E CESAR E CHAVEZ AVE	90033	14	129A223   316	5183004018	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.04678	-118.20819	PLAN CHECK FOR TITLE 24 ONLY FOR AN ICECREAM SHOP SCOPE INCLUDES 1933 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25381	15041-20000-32538	12922 W PIERCE ST	91331	7	207B161    22	2536016009		North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.26617	-118.41456	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT .CHG OF USE OF PORTION OF INDUSTRIAL BLDG TO FOOD MFG. 4307 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25382	11041-10000-26584	577 W MT WASHINGTON DR	90065	1	147A221    56	5465027001	RE40-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Expired	02/18/2014 12:00:00 AM	ADDRESS	34.09814	-118.21627	New 3.6KW roof mounted M215 Enphase Microinverter photovoltaic system for a single family residence	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25383	18041-20000-48286	403 S HIGHLAND AVE	90036	4	135B185   254	5507013001	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.06668	-118.33875	Plan check for a PV1 roof-mounted PV system. System size is 13.68 kWdc/12.31 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (38) modules.Note: Permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25384	15041-10000-34047	1800 S AVENUE OF THE STARS 6th Floor-Restroom	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	Title 24 plan check only.  Total area = 335 sq. ft.    T.I. to existing restroom space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25385	16041-10000-20433	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	PC FOR FA SYSTEM WITH MAIN PANEL AND 15 DEVICES AND 2 PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25386	16041-10000-42999	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Closed	04/17/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES ADDING  NEW SUBSTATIONS, ONE NEW GENERATOR AND  NEW ELECTRICAL EQUIPMENT  FOR THE PHASE-2 OF LOS ANGELES MEMORIAL COLISEUM. TOTAL AFFECTED AREA IS 131,631 SQ. FT. REFERENCE APPLICATION: 17041-10000-17773                                                     B#16016-10000-27246	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25387	19041-20000-51140	22325 W KINZIE ST	91311	12	201B101   196	2727005014	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.24865	-118.61352	Plan check for PV roof mounted  system, PV system size: 10.8KW DC, 10.0KW AC with 36 PV Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25388	11041-20000-27162	3470 S TROUSDALE PKWY 3rd-10th Flr	90089	9	120A201    75	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM			PC Approved	12/21/2011 12:00:00 AM	ADDRESS	34.02202	-118.28393	T-24 and ememergency lighting review for the 3rd to 10th floor remodel.  Existing and new lighting fixtures installed using existing branch circuits.  120 volt circuits for emergency and 277 for normal lighting.  Less than 400 amperes of  load added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25389	11041-10000-22819	400 S HOPE ST	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM			PC Approved	10/25/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	T.I. to the 5th floor restroom of an existing commercial building.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25390	12041-10000-23751	515 S FLOWER ST	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	IN EXISTING OFFICES , REMODELING A CONFERENCE ROOM AND  OFFICESPLAN CHK IS FOR TITLE 24SUITE 1020	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25391	14041-10000-05711	1900 S AVENUE OF THE STARS 6th FLOOR	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.05979	-118.41671	REPLACE 11 FIXTURE IN THE CORRIDOR. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25392	16041-20000-34885	17451 W OSBORNE ST	91325	12	195B129   117	2768020012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Issued	11/01/2016 12:00:00 AM	ADDRESS	34.23355	-118.51524	"""0$ permit fees due to senate bill 1222""PV1.  Install roof mounted grid-tied PV system.  (2) 7.6 kW utility interactive inverters with (52) modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25393	13041-10000-30707	1810 S BROADWAY	90015	14	123A207    63	5126029009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.03232	-118.26486	"FULL PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO (E) RETAIL FROM ""BROADWAY RETAIL STORE"" TO ""ASHLEY FURNITURE STORE"". CHANGE OF USE FOR 2 LEVELS. TOTAL INDOOR ILLUMINATED AREA IS APPROXIMATELY 48640 SQ FT. EXISTING 800A METER/MAIN 277/480V, 3-PHASE 4-WIRE. ADDITIONS OF 1 NEW 150A PANEL ""21B"", NEW CKTS. DESIGN BUILD C10 CONTRACTOR."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25394	18041-20000-39536	8550 W WENTWORTH ST	91040	7	207B189   169	2555003002	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.26677	-118.31971	Plan check for PV roof mounted with Energy storage system, PV system size: 4.575kW with 15 PV Modules and 1 inverter(3.8kw) and 1 Tesla Battery 2.0 13.5kWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25395	17041-10000-10688	634 E 27TH ST	90011	9	120A207   407	5128012005	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.02092	-118.26278	PC FOR PV SYSTEM ROOF TOP. SYSTEM USES 10 MODULES AND 3.8KA AC INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25396	13041-10000-16058	2601 S FIGUEROA ST	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.02804	-118.2763	Commercial TI for Auto Club-owned facility.  Reduction of office space to make room for expansion of emissions testing center and dynamometer.  Upgrade of restrooms to meet ADA compliance.  New panel rated 600 A bussing.  Power and energy plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25397	10041-10000-19087	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	2951.01	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	33.77884	-118.29327	INSTALL TWO NEW 480 V FEEDERS TO NEW REMOTE ELECTRICAL ENCLOSURE FOR REFINERY AREA. PLAN CHECK IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25398	16041-10000-07425	1380 W CAPITOL DR 303	90732	15	021B193    53	7445004***	R3-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	33.75409	-118.30814	PC FOR A FIRE ALARM PANEL REPLACEMENT. ALL OTHER FIRE ALARM EQUIPMENT ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25399	19041-10000-52577	1038 S MARIPOSA AVE	90006	1	129B197  1490	5078016048	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	06/19/2020 12:00:00 AM		Issued	06/19/2020 12:00:00 AM	ADDRESS	34.05151	-118.2988	NEW COMMERICAIL PV1 INSTALLATION 24.6KWdc (21.27KWcec-ac) USING 82 FREE VOLT 300W MODULES, 2 FRONIUS SYMO 12.0 CENTRAL INVERTER AND 2 FRONIUS SYMO 10.0 CENTRAL INVERTER.CONNECTED TO AN EXISTING 600AMP SERVICEDue to Senate Bill AB 1414 zero fees are to be paid.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25400	11041-10000-17009	609 S GRAND AVE	90017		129A209    68	5144005022							Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.04858	-118.25572	T.I.  Aplicant had an energy only plan check previously done for restaurant.  Plan check was not informed that the restaurant was located on the ground floor of high rise building.  Inspector has requested for applicant to resubmit for energy plan check only and to make sure all emergency light and exit signs meet the requirements for a high rise.  Pkan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25401	12041-20000-24010	3415 S SEPULVEDA BLVD 1200	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.02055	-118.42347	Title 24 for Good Clean Fun, existing high rise office building. Load is less than 400 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25402	17041-10000-25279	21271 W BURBANK BLVD 1ST FL	91367	3	174B105    74	2149019002	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.17497	-118.59473	OFFICE TI. PC FOR T24 ENERGY ONLY. LIGHTING UPGRADES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25403	10041-20001-24911	408 S GLESS ST	90033	14	127-5A219 328	5171001907	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Public Safety Only			02/28/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.04265	-118.22256	Revision to approveed plans. Installing additional devices to previously approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25404	13041-10000-16738	311 E CULVER BLVD	90293	11	096B149   313	4116009056	[Q]C4-1D	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.95984	-118.44755	new 3-story commercial building;load is less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25405	19041-20000-02741	11970 N SALEM DR	91344	12	216B133   351	2606021022	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.28796	-118.50785	PV1.  Install 13.12 kW DC / 11.4 kW AC roof mounted grid tied PV system.  (41) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25406	19041-20000-37088	14822 W DELANO ST	91411	6	178-5A149 251	2241017006	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM	02/14/2023 12:00:00 AM		Issued	02/14/2023 12:00:00 AM	ADDRESS	34.18241	-118.4562	800A 240/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.  Associated building permit under 18010-20000-06350.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25407	18041-20000-29181	6801 S PARK TER Suite 525	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	33.97698	-118.39328	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement to a medical office. Total lighting area = 2,986 sq. ft.Note: Building permit has been issued under 18016-10000-19947	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25408	16041-10000-27952	13274 W FIJI WAY #100	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	33.97902	-118.43558	Plan check Title 24 only in existing space T.I. office area. Total area: 3,471 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25409	15041-20000-38780	832 N CHEROKEE AVE	90038	4	141B185    99	5524007019	RD1.5-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Issued	11/17/2015 12:00:00 AM	ADDRESS	34.08621	-118.33509	PV1, roof mounted soar panel, 7.7kW AC   (27) modules: Solarworld SW 285 Mono   (1) SB7700TL-US-22  Standrad plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25410	16041-10001-37887	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM			PC Approved	12/09/2016 12:00:00 AM	ADDRESS	33.9451	-118.37436	BATHROOM UPGRADES. PROVIDING NEW POWER AND VACANCY CONTROLS. PC FOR T24 ENERGY ONLY. PERMIT ALREADY ISSUED UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25411	12041-10001-26741	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	33.78734	-118.29768	permit to be pulled at EPC counter only. ((CHANGEs TO APPROVEd set of PLANS. luminaire type change from T5 TO T8. T24 UPDATED))PLAN CHECK FOR ENERGY AND TITLE 24 ENERGY. 3 STORY BUILDING. UNIT EQUIPMENT. OFFICES ONLY (NO EXAM ROOMS). 3214 SQFT. 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25412	18041-20000-06293	11540 W CLOVER AVE	90066	11	120B153   990	4250016014	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.02305	-118.43545	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM CONSIST OF 43 PANELS WITH P320 POWER OPTIMIZERS AND CENTRAL INVERTER (SOLAREDGE-SE11400-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25413	11041-10000-26083	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	33.94386	-118.4047	Plan check power and energy for new LAX maintenance building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25414	15041-20000-16380	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.04896	-118.25139	Plan check for power only. Project site is an existing high-rise commercial building. Project scope is the installation of an optional 600 kW generator and (1) 800-amp ATS. Optional generator is not for emergency loads; building has an existing generator for emergency loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25415	19041-10000-09695	729 S MAIN ST	90014	14	127-5A211 333	5144015054	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			03/19/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.04351	-118.25239	PC FOR NEW FIRE ALARM IN A 4 FLOOR APPARTMENT COMPLEX. SCOPE INCLUDES NEW FACP, 4 POWER SUPPLIES AND 190 DEVICES. PLANS ARE SUBMITTED FOR LAFD FOR APPROVAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25416	16041-10000-40341	3120 S KELTON AVE	90034	5	120B157   171	4254007016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.02798	-118.42112	PV INSTALL A NEW 7.521 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMIL;Y HOUSE.(23) MICROINVERTERS: SPR-E20-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25417	12041-10000-23986	8489 W 3RD ST	90048	5	138B173   683	5511013021	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	ADDRESS	34.07345	-118.37542	Plan check T24 Energy/Emergency lighting for TI (restaurant) Suite #D-105. Less than 400A installation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25418	12041-20002-10534	7515 N MASON AVE	91306	3	186B109   409	2113002014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2012 12:00:00 AM			PC Approved	09/04/2012 12:00:00 AM	ADDRESS	34.20698	-118.57991	Modification to previously approved plans for a roof mounted PV system for a single family dwelling using 37 Enphase M215 inverters in three strings, change existing service panel to 200 amperes solar ready panel, and install a 20 ampere branch circuit in the service panel to supply the locus monitor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25419	17041-20000-21147	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			06/22/2017 12:00:00 AM			Reviewed by Supervisor	07/20/2017 12:00:00 AM	ADDRESS	34.03982	-118.24098	Plan check for solar pv system, roof-mounted on apartment building.10kW ungrounded system. (36) 320W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25420	14041-10000-24927	6624 W MELROSE AVE	90036	5	141B185   613	5524017020	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM			PC Approved	09/18/2014 12:00:00 AM	PIN	34.08319175	-118.33951913	Title 24 plan check only.  Total area = 2,715 sq. ft.RENOVATION OF EXISTING COMMERCIAL SPACE TO OFFICE.  ADDITION OF 249 SQ. FT.Building application was submitted before title 24 part 6 effective date.  Building application # = 14014-10000-02766	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25421	15041-20000-15575	651 W USC MC CARTHY WAY 1ST B-17	90089	9	120A201    78	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.02135	-118.28288	Plan check for power and Title-24 (energy).  Total area = 1,261 sq. ft.  Remodeling existing lecture hall (total occupant load = 74 fixed seats).  New power and lighting.Project located in USC LVL Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25422	13041-10000-35732	555 W 5TH ST 23rd fl	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.05016	-118.25369	REMODEL OFFICE SOACE- NEW LIGHTING IN CONFERENCE ROOM AND POWER FOR WIRED OFFICE FURNITURES-ADDED LOAD IS LESS THAN 400a	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25423	17041-10002-15998	15031 W RINALDI ST	91345	7	213B145    64	2664022028	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	34.27918	-118.46029	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 11 ONLY. ADDING ONE NEW BRANCH CIRCUIT, REDUCING AND ADDING LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25424	14041-20000-08959	7911 S NAYLOR AVE	90045	11	099B165   634	4107001015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	33.96665	-118.39544	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMED INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25425	15041-10000-24710	2338 N BRONSON HILL DR	90068	4	153A191   415	5587028021	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.11235	-118.31529	PV1, ROOF MOUNTED SYSTEM. 37 MODULES AND 1 INVERTER 7.6KW. TOTAL SIZE, 9.8KW. (37) KYOCERA #KU2656ZPA(1) FRONIUS #PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25426	14041-10000-02989	1525 W 8TH ST	90017	1	130-5A205 133	5142023005	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			02/03/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.05212	-118.27128	FA TO 8 UNIT  APT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25427	19041-20000-41033	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25428	17041-10000-33147	2828 E BLANCHARD ST	90033	14	129A227   148	5178009039	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.04836	-118.19813	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 18300 SQ.FT (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25429	16041-10000-06884	12700 W MILLENNIUM #2	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(16) ACM SPR-X20-250-BLK-B-AC MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25430	19041-10000-09560	618-624 E 4TH ST UNITS A-F	90013	14	127-5A215 183	5147010018	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.04397	-118.24027	PLAN CHECK FOR T24 ONY, TENANT IMPROVEMENT TO EXISTING RETAIL ON GROUND FLOOR TO CREATE NEW RETAIL TENANTS SPACES, NEW LIGHTING AND POWER FED FROM EXISTING SERVICE IN THE BUILDING. TOTAL AREA UNDER THE SOW: 4200 SQ.FT.BUILDING IS UNDER SINGLE MANAGEMENT PER APPLICANT.<< NON-STRUCTURAL PARTITION WALLS, ALL (E) STRCTURAL WALLS TO REMAIN. NO CHANGE IN USE. B# 18016-10000-38439>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25431	14041-20000-21290	12045 W GUERIN ST	91604	2	165B165   991	2368004011	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Apartment			08/07/2014 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.14635	-118.39389	New 16-Unit, 4-Story Apartment building with subterranean garage.  Install new 1200A service, panels, and lighting.  Plan check for power and energy.Note: Variance to separate fire alarm plans submitted 8/7/14.  Building Plans submitted on 2/10/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25432	15041-10000-07456	758 N NEW HIGH ST	90012	1	133-5A215  41	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Expired	05/16/2017 12:00:00 AM	ADDRESS	34.06161	-118.23772	TI 24  ONLY IN OFFICE BUILDING 2 FLOORS, INTERIOR AND SOME OUTSIDE LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25433	15041-10000-32912	2429 S JULIET ST	90007	8	123B197   702	5054020016	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Apartment			10/05/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.0337	-118.2956	Installation of new manual fire alarm system.  FACP and 27 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25434	18041-10000-18588	333 W 73RD ST	90003	9	102B201   990	6031003002	R2-1	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Expired	10/17/2023 12:00:00 AM	ADDRESS	33.97381	-118.27956	Plan check for a PV1 2.66KW DC / 3.0KW AC Roof mounted system. Scope includes (9) modules, (9) power optimizers, and  (1) 3kw central inverter interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25435	13041-10000-25953	6255 W SUNSET BLVD # 714	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	T.I. IN (E) 1230 SQFT OFFICE SPACE - ADD NEW NON-BEARING PARTITION WALLS, DOORS, CEILING AND FINISHES.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25436	14041-20001-00334	10451 W BELLAGIO ROAD	90077	5	141B153   180	4362020004	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.08138	-118.43908	5/18/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES. RELOCATION OF MAIN SWITCHBOARD, CHANGES IN FEEDER SIZES, REVISED AIC CALCS AND VOLTAGE DROP(((pc for power and energy. NEW SFD, 2-STORY W/ BASEMENT GARAGE (13010 10000 04375). with 60kw optional standby generator  (Plan check per 2010 LAEC) electrical permit have been paid under the building  app #13010-10000-04375)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25437	18041-10001-46516	3096 S MCCLINTOCK AVE 1425	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.02647	-118.28575	CHANGES TO APPROVED SET OF PLANS - CHANGES ONLY INCLUDE ALTERATIONS TO EMERGENCY LIGHTING SYSTEM - ALL OTHER EQUIPMENT REMAINS THE SAME ORIGINAL PERMIT PLAN CHECK FOR TITLE 24 ONLY FOR - CHANGE OF USE. CONVERSION OF STUDENT LOUNGE TO CREDIT UNION. INSTALLATION - TOTAL AFFECTED AREA = 960SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25438	15041-20000-18966	3733 S MOTOR AVE	90034	5	120B165  1312	4314003036	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Issued	08/14/2015 12:00:00 AM	ADDRESS	34.02181	-118.40526	Plan check for a PV2 roof-mounted PV system. System size is 18 kWac and consists of (2) inverters, (100) modules, (100) power optimizers, (1) load center, and (2) combiner boxes.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25439	15041-10000-06221	13128 W KAGEL CANYON ST	91331	7	204B161   719	2623020011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.25276	-118.41846	PV1 standard plan. 5.886 KW  roof-mounted system including (1) SB6000-TL  inverter, and (18) Sunpower SPR327  modules interconnecting to the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25440	18041-20000-36255	4668 N BLACKFRIAR ROAD	91364	3	168B097   685	2076012016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Expired	04/27/2024 12:00:00 AM	ADDRESS	34.15369	-118.62178	Plan check for a PV1 roof-mounted PV system. System size is 12.16 kWdc/11.4 kWac and consists of (1) inverter and (38) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25441	17041-20001-37021	820 S SHERBOURNE DR	90035	5	135B173  1011	4333024030	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			06/06/2019 12:00:00 AM			PC Approved	07/19/2019 12:00:00 AM	ADDRESS	34.06237	-118.37917	Redesign of new 6-unit 4-story apartment building.  600A 240/120V 1ph-3w and 300A 240/120V 3ph-4w services.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25442	18041-20001-10621	1901 N ECHO PARK AVE	90026	13	142-5A211  34	5420022023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Apartment			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.0864	-118.25188	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. CHANGES INCLUDE ADDING NEW FIRE PUMP RATED AT 600 AMP DISCONNECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25443	16041-20000-21738	22919 W CALVERT ST	91367	3	177B097   347	2039014018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.18114	-118.626	Plan check for PV roof mounted system. System size: 7.7kW with 36 modules and 1 inverter(7.7kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25444	17041-10000-30386	4247 N EAGLE ROCK BLVD	90065	14	156A219    67	5473024025	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Apartment			08/24/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.12274	-118.22392	PC FOR NEW FA FOR APARTMENT BLDG. SCOPE INCLUDES 153 DEVICES AND 5 PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25445	11041-20000-03901	9053 N NORRIS AVE	91352	6	195B173   114	2408036045	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.23319	-118.37711	New 4.16KV for new equipment and future equipment at existing auto processor site.  Feeders supplying future equipment. Site located on methane buffer zone. Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25446	19041-10000-43252	1804 S COCHRAN AVE	90019	10	126B177   336	5067020003	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Apartment			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.04403	-118.35378	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3KWac/4.060KWdc. SCOPE OF WORK INCLUDES 14 MODULES (HYUNDAI HIS-S290RG) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE3000H-US).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25447	15041-10000-16625	3785 W WILSHIRE BLVD STE 11-12	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.06187	-118.30858	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 1335.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25448	13041-10000-35705	1015 S CROCKER ST #R32	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 420 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25449	19041-20000-42911	6120 N WOODMAN AVE	91401	2	177B157   573	2330014028	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Apartment			10/21/2019 12:00:00 AM	10/01/2021 12:00:00 AM		Permit Finaled	12/07/2023 12:00:00 AM	ADDRESS	34.18181	-118.43105	Install new 800 amp 3 phase 120/240 volts service. Provide (17) new panels, loads and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25450	16041-10000-17056	8708 W OLIN ST #1-6	90034	10	123B169   518	4312003032	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Apartment			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.0348	-118.38263	New fire alarm system for a 3-story, 6 unit apartment building with attached garage, with 1 FA panel, 1 communicator, 38 fa devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25451	16041-10000-03454	4858 N VAN NUYS BLVD	91403	4	169-5A151  96	2248006001	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.15928	-118.4485	Full PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO DENTAL OFFICE. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES IN THE EXAMINATION, AND OFFICE SPACE. TOTAL AFFECTED AREA IS 1612 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25452	11041-10000-26891	10050 W RIVERSIDE DR	91602	4	165B181    65	2424010040	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.15198	-118.3498	Plan check power and energy for new Chase Bank building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25453	14041-10000-12136	13212 W SATICOY ST	91605	2	186B157   215	2303023041	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.2077	-118.42068	Title 24 only -remove HID fixtures and replace with fourescent fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25454	19041-10001-00294	7503 N BALCOM AVE	91335	3	186B129   529	2120029031	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.20678	-118.52092	Supplemental Delta 1 changes to an approved set. Upgrade the size of the main sevice panel from 125A to 225A. Panel upgrade permit willl be pulled seprately by the contractor. Original Scope of Work>>>>>NEW ROOFTOP SOLAR SYSTEM CONSIST OF 14 MODULES (Q-PEAK 315W) , 14 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 4.41KWdc and 3.8KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25455	15041-10000-12640	6255 W SUNSET BLVD SUITE 1111	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	TI-24 TO AN (E) HIGH RISE BUILDING. PC FOR ENERGY ONLY. TOTAL SQ. FT. 4275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25456	13041-10001-24739	2506 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.0335	-118.2974	EXPEDITED PER APPLICANTS REQUESTROOFMOUNTED SOLAR ARRAY. TRANSFORMERLESS. SYSTEM SIZE: 2.94 KW. 12 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25457	18041-20000-16013	4040 N FARMDALE AVE	91604	2	162B169   399	2368023038	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Issued	05/01/2018 12:00:00 AM	ADDRESS	34.14121	-118.38101	Plan check for power only. Work includes the installation of (2) Tesla PowerWalls and (2) load centers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25458	18041-20000-22671	13060 W ROSCOE BLVD	91352	2	192B161   102	2304005023	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	08/11/2021 12:00:00 AM	ADDRESS	34.2215	-118.41867	PV2.  Install 61.2 kW roof mounted grid tied PV system.  (170) modules with 20 and 30 kW rated central inverters.Fees $0 due to California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25459	19041-20000-35585	16760 W RAYEN ST	91343	12	195B137   394	2688031017	RA-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.23199	-118.49815	PV1.  Install 6.4 kW AC roof mounted grid tied PV system.  (2) strings of (10) AC modules on two different 100A busses on split bus MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25460	19041-20001-19433	23329 W OSTRONIC PL pv1	91367	3	171B093   647	2044024020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.16295	-118.63509	expeditepv1install roof mounted pv system sized 14.8KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25461	17041-10000-03124	2049 S CENTURY PARK EAST 20TH	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY ONLY. T.I. IN BATHROOM FOR MORE ACCESSIBILITY ON THE 20TH FLOOR. ADDING NEW LIGHTING AND POWER. AREA IS 410 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25462	17041-10000-04273	730 E 17TH ST	90021	14	121-5A209  48	5131001048	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.02848	-118.25556	PC FOR LIGHTING UPGRADES TO EXISTING LIGHTING. REPLACING FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25463	19041-20000-22683	9761 N ABREGO CT LOT 12	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.24766	-118.45072	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25464	14041-10001-26902	18541 W VINCENNES ST 1-59	91324	12	198B125   156	2763035006	R3-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Apartment			09/30/2014 12:00:00 AM			PC Approved	10/20/2014 12:00:00 AM	ADDRESS	34.24104	-118.53737	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 24,400W DC.(80) CANADIAN SOLAR CS6X-305M(1) FRONIUS IG PLUS 11.4-3(1) FRONIUS IG PLUS 10.0-1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25465	14041-10000-17219	8436 W 3RD ST	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.07301	-118.37448	Title 24 plan check only.  Total area = 925 sq. ft.Lobby lighting improvements, conduit only installation for shell conditions for (2) future tenant spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25466	16041-30000-17738	2901 S CENTRAL AVE	90011	9	117A209   108	5128021001	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.01561	-118.25643	Plan check for a fire alarm system for a 1 story commercial building. System consists of (1) FACP, (1) RPS, (1) annunciator, and (34) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25467	14041-20000-21768	18860 W NORDHOFF ST 1st Floor	91324	12	195B121    16	2770001031	C2-1VL, [Q]CR-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.23527	-118.54455	TI to commercial office and studio.  Plan check for energy under 2013 Title 24 Part 6 requirements.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25468	16041-10000-29143	660 S FIGUEROA ST	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	04/13/2017 12:00:00 AM		Issued	04/13/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR POWER AND ENERGY. CHANGE OF USE FROM BANK TO RESTAURANT. T.I. FOR A CHICK-FIL-A RESTAURANT ON THE FIRST FLOOR WITH BASEMENT. USING A NEW 600A FEEDER FROM AN EXISTING 5000A SERVICE. TOTAL AFFECTED AREA 4100 SQ FT.B# 16016-10000-19258.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25469	12041-10001-03830	440 S SEATON ST	90013	14	127-5A215 363	5163025008	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			PC Approved	07/27/2012 12:00:00 AM	ADDRESS	34.0421	-118.23734	Modification to previously approved set of plans.  Plan Check Only for Delta 2 Changes Only.           <<<<<<PLAN CHECK NEW 600A SERVICE FOR EXISTING WAREHOUSE BUILDING. SITE IN METHANE ZONE.>>>>>.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25470	17041-20001-23671	20016 W BLYTHE ST	91306	3	189B113   328	2106002***	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	08/04/2017 12:00:00 AM	ADDRESS	34.21466	-118.56922	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25471	19041-20000-51940	13453 W KESWICK ST	91402	6	189B157   846	2301014005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM			Corrections Issued	12/17/2019 12:00:00 AM	ADDRESS	34.21132	-118.42641	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 5.76 KW DC/5 KW AC. SCOPE OF WORK CONSISTS OF (18) PV MODULES WITH OPTIMIZERS AND A 5 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25472	17041-20000-35812	24022 W SCHOENBORN ST	91304	12	192B089   149	2017037017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.22111	-118.64972	pv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25473	17041-10000-22797	11601 W WILSHIRE BLVD 18TH FLR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR RESTROOMS CORRIDOR AND LOBBY  TI IN A HIGH RISE (18th FLOOR) FOR TITLE 24  ENERGY ONLY. TOTAL AFFECTED AREA  1600 SQ.FTINSTALLING NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25474	17041-10000-14117	1755 N GLENDALE BLVD	90026	13	144A209   285	5423006033	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.08742	-118.25984	PLAN CHECK FOR ENERGY (T24) THIS PLAN CHECK IS ONLY SUBJECT TO 2ND AND 3RD FLOOR ONLY.  CHANGE OF USE OF  (E) 2 STORY COMMERCIAL BUILD. FROM  LEATHER GOODS MANUFACTURING  BUILDING TO FIRST FLOOR  GYM , 2ND AND 3RD FLOOR OFFICE. TOTAL AREA: 3216 SQ.FTB# 14016-10001-09737	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25475	15041-20004-07849	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.12774	-118.26247	[[03/29/2016. changes to approved set of plans. plancheck only. changes to the circuit and the location of receptacles in the photoarea. ]]]09-04-2015 Change to an approved set of plans. Changes include relocation of hearing booths and alter lighting for photo center. Changes apply to Delta 6 only. **************************************************************08/05/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 5. Changes include the addition of  receptacles and lights onto existing circuits.*****Previous Work Description*****Change to approved set. Plan check for Addition of 2  new hearing exam booths to Costco. No light is being add to the 2 new booth; light is part of the booth. {{{{{{PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COSTCO OPTOMETRY ROOMS. NOT A MEDICAL ( CONSULTATION ONLY) 615 SQFT.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25476	13041-20001-34261	6844 N WOODMAN AVE	91405	2	183B157   830	2328012040	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			01/05/2017 12:00:00 AM			PC Approved	01/05/2017 12:00:00 AM	ADDRESS	34.19531	-118.43098	(1/5/2017)CHANGES TO AN APPROVED SET OF PLANS.  CHANGE ELEVATOR BREAKER TO 225AMP TO MEET MANUFACTURE REQUIREMENTS.   THIS IS PLAN CHECK ONLY.(((NEW 15 UNIT APARTMENT.  NEW 1000A SERVICE.  PLAN CHECK FOR POWER AND ENERGY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25477	19041-10000-27756	731 N FAIRFAX AVE	90036	5	141B177   410	5527012006	C2-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Info Complete	07/18/2019 12:00:00 AM	PIN	34.08474652	-118.36182228	NEW FIRE ALARM IN A 43 UNIT APPARTMENT COMPLEX. SCOPE INCLUDES NEW FA PANEL, ANNUNCIATOR, COMMUNICATOR AND 86 DEVICES.Withdrawn by applicant on 02/20/2024 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25478	18041-10000-13222	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES THE ADDITION 2 NEW GATES AND RELOCATE 1 FOR TERMINAL 2. NEWLY CONNECTED LOAD IS > 400AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25479	14041-20000-23236	15829 W TUPPER ST	91343	12	198B141   434	2671032025	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.23933	-118.47748	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25480	19041-10000-43042	3101 W EXPOSITION BLVD	90018	10	120B185  1292	5044003016	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	03/12/2020 12:00:00 AM		Permit Finaled	03/29/2021 12:00:00 AM	ADDRESS	34.02175	-118.32982	PLAN CHECK FOR POWER AND ENERGY FOR SERVICE RATED AT 3000A , 480/277 V AND ASSOCIATED EQUIPMENT. TOTAL AFFECTED AREA FOR TITLE 24- 67050SQ/FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25481	13041-10000-03701	13261 N HERRICK AVE	91342	7	225B145   289	2501009060	RS-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.31194	-118.46198	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE STORY HOME. [INVERTER: POWER ONE # PVI-4.2 (TRANSFORMERLESS) |||| MODULES: SUNPOWER # SPR-327NE-WHT-D] 14 MODULES IN TWO STRINGS. SYSTEM SIZE IS 4.578 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25482	12041-10000-10209	8475 W MELROSE PL	90069	5	141B173   426	5528001057	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.08373	-118.37591	T.I. to an existing restaurant space.  Lighting change, new receptacles.  Load is less than 200A and occupancy load is 60, per applicant.  If occupancy load is greater than 99 a full plan check will be required.  This application is a PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25483	18041-10000-48930	1212 W MANCHESTER AVE	90044	8	097-5A197 349	6047002003	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.9598	-118.29644	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25484	14041-20000-14839	9543 N GIERSON AVE	91311	12	201B101   557	2727010010	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.24392	-118.61171	3.5kw PV1 standard plan with 14 SolarWorld  SW255 mono/ 2.5 Frame modules, and a Powerone PVI-3600TL-US inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25485	10041-20000-04842	13164 W BURBANK BLVD	91401	5	174B157   656	2345005022	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	34.17196	-118.4201	delta 4 revisions to 02041-20000-12117	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25486	17041-10000-20922	5748 N IRVINE AVE	91601	2	174B169   373	2338019015	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.1753	-118.38541	PC FOR PV SHINGLES, ROOF MOUNTED. TOTAL SYSTEM SIZE 5.2kw ac using central inverter. zoning covered under building permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25487	15041-10000-27869	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.06725	-118.41704	Plan check for new medium voltage 4.16KV service, site medium voltage unit substation distribution, and equipment for existing country club. Site located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25488	18041-20000-16489	14903 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29438	-118.45525	PV1.  Install 3 kW roof mounted grid tied PV system.  (11) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25489	11041-10000-16282	425 N MISSION ROAD UNIT B	90031	14	130-5A219  46	5410006008	[Q]M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.20	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	PIN	34.05357026	-118.22683422	T.I. FOR INDUSTRIAL STORAGE  BUILDING.   PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25490	14041-20000-11863	10261 W ARNWOOD ROAD	91342	7	210B181    23	2529004001	RE11-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.27538	-118.35277	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.7KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25491	14041-10000-27641	211 S LA BREA AVE	90036	5	138B181  1307	5513022012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.07066	-118.34433	INSTALLATION OF  METHANE MITIGATION ACTIVE SYSTEM. 1 PANEL AND 22 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25492	18041-20001-03152	11710 N BALBOA BLVD	91344	12	213B133   166	2610002017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM			PC Approved	02/21/2018 12:00:00 AM	ADDRESS	34.28325	-118.50187	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (38) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25493	11041-20000-18265	6333 W 3RD ST #522	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			Corrections Issued	08/26/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	The Magic nut & candy co. t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25494	13041-10001-31568	1605 N CHEROKEE AVE	90028	13	148-5A185 268	5547014904	PF-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM			PC Approved	10/29/2015 12:00:00 AM	ADDRESS	34.09994	-118.3353	((10/29/2015))CHANGES TO APPPROVED SET OF PLANS.  CHANGES NOTED DELTA 11.  CHANGES INCLUDE CHANGE OF FEEDERS FROM CU TO AL.  THIS IS PLAN CHECK ONLY. New 66-Unit Affordable Housing Apartment Building - 5-stories over podium with two subterenean parking garages. Building permit is 13010-10000-02864	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25495	13041-10000-04971	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check power. LAX Terminal 5. Remove existing 3000A switchboard 2HPJ3 from Main #1 4000 service and reconnect to BMS5. Temporary installation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25496	14041-20000-11261	16911 W VENTURA BLVD	91316	5	168B133   103	2258018004	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.15959	-118.50159	PLANCHECK FOR T24 ENERGY. BUILDING SHELL UPGRADE. NO CHANGE IN OCCUPANCY, NEWLY CONNECTED LOAD <400 AMPS. OUTDOOR LIGHTING 2966 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25497	15041-20001-36375	10420 N SEPULVEDA BLVD BLDG 2	91345	7	204B145    23	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	34.25976	-118.46706	Revisions to approved set of plans.  Value engineering changes and gear orientation revision.  Approval for clouded changes delta-J only.  (((NEW TWO FLOOR MULTI USE BUILDING. CORE AND SHELL ONLY.  PLAN CHECK FOR POWER AND ENERGY.BUILDING APLLICATION# 15010-10000-03863)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25498	14041-10000-29090	907 W 85TH ST	90044	8	097-5A199 121	6032012014	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	33.96135	-118.28942	PV1.  Install 5.1 kW roof-moutned, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25499	13041-20000-09085	5120-5124 N ZELZAH AVE	91316	5	171B129   238	2162012010	QC1-1VL, QP-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.16408	-118.52188	"Plan check for energy and emergency lighting. Lucky Coin Laundry.REVISION TO PCIS #08041-20000-08413 (Tenant improvement/repair after fire damage (>84KVA) in ""Lucky Coin Laundry""). ADDED FAULT CURRENT CALCULATIONS AND CHANGED AIC RATINGS OF EXISTING PANELS & BREAKERS APPROPRIATELY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25500	11041-20000-00074	6600 N TOPANGA CANYON BLVD #2067	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to existing building.  Install general/emergency lighting in storage room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25501	10041-10000-08030	4775 N TOPEKA DR	91356	3	168B121   255	2176031031	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2010 12:00:00 AM	06/25/2010 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.1569	-118.54918	New single dwelling building.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25502	12041-10000-18753	349 S BROADWAY	90013	14	130-5A211 143	5149015021	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.05002	-118.24926	Two new exterior lights and one circuit for a future sign for a shell building.  PLAN CHECK ONLY for Energy for the exterior light and sign.  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25503	19041-10000-51244	11242 N ALTA AVE Lot 31	91345	7	210B145   547		C1-1VL, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.27485	-118.46879	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 13 MODULES (13 HANWHA Q.PEAK BLK-G5315), 13 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)SYSTEM SIZE: 4.095 KW DC;  3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25504	19041-10000-07703	2155 N STRADELLA ROAD	90077	5	150B145    31	4377028001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.11089	-118.46248	$0 permit fee due to state bill 1414.PV1 ROOF MOUNTED SYSTEM USING CENTRAL INVERTER AND POWER OPTIMZERS. TOTAL NUMBER OF MODULES 44, 44 OPTIMZERS , (2) 7.6 KW INVERTERS. TOTAL SYSTEM SIZE 15.8 KW DC, 14.05 KW AC CEC, 15.2 KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25505	17041-20000-19768	337 N BENTON WAY	90026	13	138A203    72	5156025015	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village		1958.02	Electrical	Electrical	Apartment			06/19/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.07394	-118.27518	ti to an existing apartment building.  service upgrade 600 amps.  plan check for power and energy.  building application number 17016-30000-04208	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25506	15041-20000-05620	17200 W VENTURA BLVD SUITE 229A	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	34.16035	-118.50769	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS AND BATHROOMS FOR NAIL GARDEN. 120 SQFT. SUITE 229A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25507	18041-10004-14610	3260 S CLUB DR	90064	5	123B165   698	4316030025	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM			PC Info Complete	09/13/2018 12:00:00 AM	ADDRESS	34.0328	-118.40233	CHANGES TO APPROVED SET.  (Removed 3 disconnects for the battery storage and modified the load center)THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25508	19041-20000-09958	515 S FIGUEROA ST Ste 1020	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI to (E) commercial office space.  Plan check for energy - 1577 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25509	19041-20000-13120	6040 W CENTER DR 1-218	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Issued	05/21/2019 12:00:00 AM	ADDRESS	33.97574	-118.39042	Plan check for a PV2 roof-mounted PV system. System size is 71.18 kWdc/65.04 kWac-CEC and consists of (2) inverters, (195) modules, (1) transformer, and (2) load centers.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25510	14041-10000-11993	8201-8203 W 3RD ST	90048	5	138B173   840	5511019036	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.07259	-118.36814	Plan check for power and energy. Core and Shell only. Tenant to pull separate permit for TI.  TOTAL AREA INDOOR 1306 SQ FT. BLDG#14010-10-01124: PROPOSED NEW 1 STORY RESTAURANT W/ROOF DECK OUTDOOR DINING AREA - CORE & SHELL PERMIT (T.I. UNDER SEPARATE FUTURE PERMIT). SEE COMMENTS. TV = 220,000 (1 OF 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25511	18041-20000-43644	8554 N ETIWANDA AVE	91325	12	192B125   106	2786008003	R1-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.2262	-118.53158	PV1.  Install 7.59 kW roof mounted grid tied PV system.  (23) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25512	15041-10000-26595	5750 W WILSHIRE BLVD	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Expired	09/08/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	FIRE ALARM PANEL AND TRANSPONDER PANEL UPGRADES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25513	16041-10000-44814	1609 N MAGNETIC TER	90069	5	147B169   322	5561013014	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2016 12:00:00 AM			PC Info Complete	01/30/2017 12:00:00 AM	ADDRESS	34.10018	-118.39177	NEW SFD DWELLING. 80% COMPLETE BASED ON 2011 BUILDING STANDARDS. THIS IS ELECTRICAL PORTION. PC FOR POWER ONLY. ELECTRICAL FEES COLLECTED FROM BUILDING /COMBO PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25514	16041-20000-33905	10051 N HEATHERGLEN CT	91325	12	204B129   594	2734006011	RA-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.25383	-118.52218	Plan check for a PV1 roof-mounted PV system. System size is 6.5 kWac and consists of (20) AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25515	16041-20000-04872	5754 N CHICOPEE AVE	91316	5	174B129   275	2254020018	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.17564	-118.51214	Plan check for a PV1 roof-mounted PV system. Addition of a 3 kWac system onto an existing 3 kWac for a total system size of 6 kWac. Addition consists of (1) inverter, (8) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25516	17041-10000-34978	3523 S CENTINELA AVE 2-7	90066	11	114B153   477	4246006001	[Q]C1-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.00999	-118.43857	PC FOR FIRE DAMAGE REPAIR TO EXISTING COMMERCIAL BUILDING FOR POWER AND ENERGY. TOTAL CONNECTED LOAD >400A.  SERVICE EQUIPMENT TO REMAIN. SCOPE INCLUDES  NEW PANELS, CIRCUITS AND EQIPMENT. TOTAL AFFECTED AREA 7665 SQ.FT. (INDOOR AND OUTDOOR)B# 17016-10000-28385	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25517	18041-10000-37428	8905 W VENICE BLVD	90034	5	123B169  1508	4312011036	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.02929	-118.38914	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25518	16041-10000-07724	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	33.98489	-118.42552	PROPOSE TO INSTALL CLEAN ENERGY SERVERS 4 - 250KW ES 5 ON A PRECAST PAD OF THE DIRECT TV WITHIN (E) PARKING LOT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25519	12041-20000-30634	19300 W RINALDI ST SUITE L	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.27414	-118.55457	Plan check for energy and emergency lighting. Hallway only. 639 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25520	17041-10000-00786	6081 W CENTER DR suite 208	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	33.97811	-118.39245	T-24, PC FOR ENERGY ONLY. TI FOR BEN & JERRY'S ICE CREAM. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1290 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25521	16041-10001-25353	10250 W SANTA MONICA BLVD 3750	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES INCLUDE NOTATION UPDATES. PROVIDED MORE CONSISTENT CALL OUTS FOR BREAKER SIZES AND WIRE SIZES. THIS IS PC ONLY NO PERMIT UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25522	17041-20000-14347	8110 N LANKERSHIM BLVD	91605	6	189B169    62	2311005040	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	PIN	34.21795078	-118.38731326	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25523	16041-10000-23577	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.04337	-118.23442	Installation of a new fire alarm system to a commercial building. Installing 132 fire alarm devices, and 3 fire control panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25524	19041-10001-44017	11429 W BIONA DR	90066	11	114B157   347	4234008038	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM			PC Info Complete	11/15/2019 12:00:00 AM	ADDRESS	34.01094	-118.42283	"DELTA ""1"" Changes to approved plans. Changing the layout of PV Panels on the roof.There are no changes to the number of PV Panels and the rating of the PV system.<<<PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 12 (POWER XT-360R-PD) MODULES, 12 (P370) OPTIMIZERS,  1 (SOLAR EDGE SE3800H-US) INVERTER, CONNECTED TO AN EXISTING 200A PANEL. SYSTEM SIZE IS 4.32KW DC AND 3.80KW AC.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25525	12041-10000-13572	6330 W SAN VICENTE BLVD	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM			PC Approved	06/13/2012 12:00:00 AM	ADDRESS	34.06116	-118.36804	Plan check for energy and emergency lighting. Occupancy is less than 100. Low rise commercial. 2912 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25526	16041-10000-41267	7230 W MULHOLLAND DR	90068	4	156A181   647	5572001005	OS-1XL, R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.1201	-118.34876	PC for new PV 10.95KW rooftop system with 33 modules and 33 optimizers.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25527	14041-10000-06893	231 E WINSTON ST	90013	14	129A213   318	5148007008	C2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.04601	-118.24613	PLAN CHECK FOR FIRE ALARM .( TWO STORY  DORMITORY FOR HOMELESS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25528	18041-20000-36177	1611 S PERRINO PL	90023	14	118-5A219  11	5169015010	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	08/26/2020 12:00:00 AM		Issued	08/26/2020 12:00:00 AM	ADDRESS	34.01996	-118.22265	600A 480Y/277V 3ph-4w service upgrade for (E) commercial building.  Plan check for power.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25529	17041-10000-10678	24105 S FRAMPTON AVE	90710	15	039B197    42	7439011038	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	33.805	-118.29924	TI TO AN EXISTING WHARHOUSE, NEW EXTERIOR OPENINGS. NEW LIGHTING. EXISTING SERVICE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25530	14041-10001-02757	6029 N NEDDY AVE	91367	3	177B089   502	2045004004	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.18066	-118.65271	Expedited RSES plan check per appllicant request.{{PV1, Install 1126 kW DC roof-mounted solar array for a residential home, interconnect with existing service panel. (2)Transformerless inverters: POWER-ONE  PV1-6000-TL(52) Modules: ET BLACK Modules}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25531	14041-20003-17398	5268 N TUJUNGA AVE	91601	2	171B173   338	2350017008	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.16676	-118.37882	09/07/2017 Changes to an approved set of plans. All changes have been clouded. Feeders have been changed to aluminum and sized accordingly. Breaker sizing for certain panels has been updated.08/25/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to feeder sizing and distribution equipment.6/16/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO LOBBY AND CORRIDOR LIGHTING . APPROXIMATELY 6000SQFT. EMERGENCY LIGHTING EXISTING TO REMAIN*****Previous Work Description*****Plan check for power energy on new built hotel, 4 stories, with 43 guestrooms  and 1 dwelling unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25532	11041-20000-18482	11262 W VENTURA BLVD	91604	2	162B173   435	2378010008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			PC Info Complete	11/16/2011 12:00:00 AM	ADDRESS	34.14102	-118.37532	Plan check power and energy for new restuarant. New 600A service supplying new restaurant and existing billboard panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25533	14041-20001-05065	2000 N LAS PALMAS AVE	90068	4	150A185   143	5575011017	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.10631	-118.33622	((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.78KW AC USING A COMBINATION OF MICROINVERTERS M215 AND CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25534	13041-20000-31943	6801 S PARK TER	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.97698	-118.39328	Existing Medical Clinic.  Not State Licensed, NOT CHECKED for OSHPD3.  Plan Check for Power and Energy.  New MRI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25535	18041-10000-37009	5711 N VAN NUYS BLVD	91401	4	174B149   556	2244028022	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.17427	-118.44907	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25536	18041-20000-48186	9132 N DE GARMO AVE	91352	6	198B173   154	2408034047	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.23512	-118.3746	Installation of compressed natural gas private fueling stations, plan check for power and energy.  (N) 1200A 480Y/277V distributon feeding from 1600A Service.  Hazardous classifications in scope of work. total area: 1387 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25537	18041-10001-20344	6505 S ESPLANADE #5	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			Reviewed by Supervisor	06/13/2018 12:00:00 AM	ADDRESS	33.96159	-118.45071	5 OF 5******EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25538	16041-10003-38993	10250 W SANTA MONICA BLVD 2705	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"3rd Changes to approved set of ""Eataly"" noted under Delta 7: add loads, revise power floor plan due to new loads."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25539	12041-10000-00435	333 S LOS ANGELES ST	90013	14	129A213   149	5148001006	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM			Reviewed by Supervisor	02/21/2012 12:00:00 AM	ADDRESS	34.04788	-118.24566	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR EXISTING R2 BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25540	14041-10000-22124	8022 W 3RD ST	90048	5	138B177   761	5511028021	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.07182	-118.36461	tWO STORY BUILDING FIRE ALARM. 20 DEVICES AND ONE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25541	18041-10000-24182	1745 N WESTERN AVE 1-24	90027	13	148-5A193  44	5544005028	C4-1D	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.10305	-118.3096	New Fire Alarm System in a 24 unit apartment building.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25542	13041-20000-27926	3723 N ROSEMEAD AVE	90032	14	144A233   286	5306015055	RD3-1	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Expired	11/24/2015 12:00:00 AM	ADDRESS	34.08787	-118.1765	PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW AC USING 14 MODULES. TRANSFORMERLESS INVERTER. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25543	14041-10001-24484	13286 W TERRA BELLA ST	91331	7	204B157   768	2623004012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.25526	-118.42226	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 3.315 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(13) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE3000A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25544	16041-10001-20683	3600 S CIMARRON ST	90018	8	120B189  1256	5042026001	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Expired	08/16/2018 12:00:00 AM	ADDRESS	34.0226	-118.31544	07/11/16PV1. PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(10)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB#PVI-3.0-OUTD-S-Z-A((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25545	19041-20000-32841	5142 N ENCINO AVE	91316	5	171B129   185	2257014021	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.16498	-118.51402	PV1.  Install 12.87 kW DC roof mounted grid tied PV system.  (39) modules with 7.6 and 3 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25546	15041-10000-43947	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	PC AND PERMIT FOR NEW FIRE ALARM PANEL AND NEW INITIATING DEVICES. ALL NOTIFICATION DEVICES TO REMIAN EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25547	13041-10000-07459	519 N OCAMPO DR	90272	11	126B129   867	4411012013	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.03759	-118.52057	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.9 KW. STANDARD PLAN. USING 20 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25548	17041-10000-26100	806 W 40TH PL	90037	9	114B197   354	5019002020	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.00998	-118.28763	SERVICE UPGRADE AND REPLACEMENT OF PANELS TO AN EXISTING APARTMENT BUILDING. 600 AMPS, 120/240, 1PH, 3W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25549	17041-20001-42366	13057 N GLADSTONE AVE	91342	7	222B157   135	2512002030	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.3074	-118.4246	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.32 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25550	17041-10000-01842	825 S HILL ST	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.04392	-118.25657	Installation for a new fire alarm in a mix used development project, high rise building. (37) Fire Alarm panels, (2919) Fire Alarm Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25551	13041-20000-11875	111 E UNIVERSAL HOLLYWOOD DR 2000	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	RENOVATION OF EXISTING OFFICES. CHANGING OUT PARTITIONS, RELOCATION OF SOME FIXTURES. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25552	16041-10002-05371	1411 S SANTEE ST	90015	14	124-5A209 275	5133016004	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.03386	-118.25947	SUPLEMENTAL PC FOR ENERGY ONLY to replace a lost set . NEW CONNECTED LOAD = 400A, TOTAL AREA 10500 SQ FT PLAN CHECK ONLY.PLAN ALREADY HAS BEEN APPPROVED UNDER THE MASTER. ADDITIONALLY,  CONTRACTOR WAS CHANGED UNDER 10001.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25553	17041-10000-16893	2333-2347 S PONTIUS AVE	90064	5	126B153  1149	4322023034	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			PC Info Complete	06/01/2017 12:00:00 AM	ADDRESS	34.03748	-118.43662	PC FOR DISTRIBUTION ALTERATION. KEEPING SERVICE POINT, REMOVE INDIVIDUAL METERINGS AND INSTEAD INSTALLING NEW METERING SECTION TO METER EACH TENANT INDIVIDUALLY. PC FOR POWER CHANGES ONLY. NO NEW LOADS. PROVIDING NEW DISTRIBUTION AND TRANSFOROMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25554	12041-10000-10110	1724 N HIGHLAND AVE	90028	13	148-5A185  63	5547011031	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.10238	-118.3385	Plan check power and energy for first time restaurant unit #100  (Thinhorn Flats)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25555	16041-10000-26322	10216 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.25596	-118.57964	"PC FOR ENERGY ONLY.COMBINE 3 TENANT SPACE INTO ONE ""AUTOZONE STORE"", NEWLY ADJUSTED TOTAL LOAD < 400A. INSTALL NEW INTERIOR AND EXTERIOR LIGHTS, TOTAL AFFECTED AREA 7413 SQ FT.B# 16016-10000-17259."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25556	16041-10001-25749	5733 S WILTON PL	90062	8	108B189  1193	5005012021	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	33.98996	-118.31508	RECHECKING LOST SET OF PLANS. RESTAMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25557	16041-20000-33673	14726 W MORRISON ST	91403	4	169-5A149  72	2263028029	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.16016	-118.45406	Plan check for a PV1 roof-mounted PV system. System size is 15.5 kWac and consists of (45) AC modules and (1) load center.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25558	15041-20001-09517	1312 N PAVIA PL	90272	11	129B133    50	4425013009	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.05327	-118.50434	12/23/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. SINGLE FAMILY HOME. TWO STORIES. 600 AMP SERVICE. 120/240 SINGLE PHASE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25559	16041-10002-12684	1429 W 81ST ST	90047	8	099B193  1053	6034005018	RD3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	33.9656	-118.30134	CHANGE TO MAIN SERVICE INTERCONNECTION. INSTALL NEW PANEL TO RELOCATE LOADS. PV INSTALL ON SUBPANEL. RELOCATION OF EQUIPMENT ON SITE PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25560	19041-10000-05325	21322 W OXNARD ST	91367	3	177B105    73	2149002013	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.17903	-118.59585	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25561	18041-20000-46688	6320 N CANOGA AVE 2nd flr	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Issued	12/10/2018 12:00:00 AM	ADDRESS	34.18499	-118.59722	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25562	15041-20000-15565	5700 W WILSHIRE BLVD Suite 250	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	TI. Title 24. Plan check for energy only. Existing high rise building. Adding new lighting including emergency. 3504 total sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25563	19041-10000-19182	7530 S WESTERN AVE	90047	8	099B193    80	6018016017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	33.97102	-118.30878	PC FOR FA SYSTEM, 1 FACP AND 36 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25564	18041-20000-46269	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM			PC Info Complete	12/05/2018 12:00:00 AM	ADDRESS	34.0834	-118.37568	Plan check for Title 4 Energy only in existing space T.I retail. total area: 1083 sq ft. B#18016-20000-18198	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25565	10041-10000-10174	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM			PC Approved	05/28/2010 12:00:00 AM	ADDRESS	34.07417	-118.26931	Remodel of  6 floor in high rise building  power and energy. Shell drawings already approved.  Existing permit.  2005 T-24 per Behzad.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25566	10041-20000-15151	1856 S SEPULVEDA BLVD 1-5	90025	5	126B153    59	4323021017	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	09/28/2011 12:00:00 AM	ADDRESS	34.04521	-118.44202	upgrade 600 amp pull section to 1000 amp and upgrading service from 400 amp to 800 amp and reconnect the existing 200 amp meter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25567	16041-20000-05735	970 W 190TH ST Ste 500	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	33.85812	-118.29302	TI to (E) commercial office space in commercial highrise building.  Plan check for energy.  3,205 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25568	13041-20000-31849	19926 W EAGLE RIDGE LANE	91326	12	219A115    47	2701015044	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.29441	-118.56699	pv1 single family dwelling. total system size 5kw ac using 21 modules. transformerless inverter. 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25569	19041-10000-34996	2417 W BEVERLY BLVD	90057	13	136-5A203 141	5157010004	C2-1	Central	Westlake	Echo Park	YES	2085.01	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	11/06/2020 12:00:00 AM	ADDRESS	34.06864	-118.27441	NEW FIRE ALARM SYSTEM IN AN OFFICE BUILDING. SCOPE INCLUDES NEW FA PANEL, COMMUNICATOR, ANNUNCIATOR AND 41 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25570	10041-10002-22716	110 S FAIRFAX AVE	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			PC Approved	05/04/2011 12:00:00 AM	ADDRESS	34.07371	-118.36119	Revised lighting plan for new restaurant, reviewed for T24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25571	14041-20000-21840	12751 W MILLENNIUM B101	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	33.9761	-118.41651	PC FOR NEW DISTRIBUTION EQUIPMENT FOR SHELL OUT A TENANT SPACE. PLAN CHECK FOR NEW 2013 BUILDING EFFICIENCY STANDARDS FOR POWER DISTRIBUTION. NEW 600A SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25572	14041-20002-26393	613 S SPRING ST FIRST FLOO-R	90014	14	129A211   246	5144002016	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.04569	-118.25144	1.29.2015 - Changes to approved set. Change fixture F2 to incandescent. Change previously emerg. F2 fixtures to normal fixtures, add  buglights to compensate. Update Title-24 forms to reflect increase in wattage. Delta 2 changes only.[[[[[ CHANGES TO APPROVED SET. PLANCHECK ONLY, CHANGES TO T24 LIGHTING ONLY. MASTER PLAN CHECK WAS FOR T24 ONLY.]]]]]]]PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE FROM LAUNDRY TO RESTAURANT.  HIGHRISE. 2000 SQFT.    EMERGENCY LIGHTING INSTALLED WITH 90 MIN BATTERY BACK UPS. BUILDING NOT PART OF GENERATOR RETROFIT. RESIDENTIAL OCCUPANCY NOT BEING CHANGED.  INSPECTOR TO VERIFY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25573	15041-20000-09078	7327 N MILWOOD AVE	91303	3	186B105   759	2112024020	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Apartment			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.20364	-118.59454	Plan check for fire alarm system for appartment. 18 fire alarm devices 5 smoke detectors and 7 number of control devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25574	16041-10002-23647	7441 W WOODROW WILSON DR	90046	4	156B177   257	2427012021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.12423	-118.35693	PC only, Changes to an approved set of plans, changes include the interconnection to the main service, addition of the pv production and reduction of a panel. All changes clouded delta 1.__________________________________________________________System size changed to 11.4KWacTotal panaels and optimizers is 43.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25575	17041-10001-38024	14060 W GARBER ST	91331	6	198B153   274	2642010001	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.24172	-118.43926	Changes to an approved set of plans. Changes include relocating modules on roof-layout.Note: Permit is pulled PCIS#17041-10000-38024	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25576	13041-10000-14182	8213 N AURA AVE	91335	3	192B117   903	2105018009	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling	1	Dwelling - Single Family	05/31/2013 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Expired	06/24/2015 12:00:00 AM	ADDRESS	34.21898	-118.55479	PV1.  Install roof-mounted solar array (1.73 kW DC), interconnect into existing 200A main service panel.  {8 modules: SunModule SW 270 mono} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25577	12041-10000-08115	1057 N VINE ST	90038	4	144B185   814	5533017010	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Public Safety Only			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.09007	-118.32679	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING- 3 STORIES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25578	16041-20000-14652	7901-7915 N RUFFNER AVE	91406	6	189B137    53	2205009039	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.21434	-118.49699	permit fee $0.00 by state senate bill no.1222Install a roof mounted solar array on a commercial building. Interconnect directly to LADWP = FEED-IN-TARIFF SYSTEM. System size: 100kW [(5) 20kW inverters]. Ungrounded system.(420) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25579	14041-10000-07859	1563 W 218TH ST	90501	15	048B193    57	7346002038	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	33.83038	-118.30596	PV1 11.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(2) inverters: {PVI-5000-OUTD-US, PVI-6000-OUTD-US}]. [(46)modules: {Canadian Solar {CS6P 250P}}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25580	17041-10000-12470	620 S BROADWAY	90014	14	129A211   228	5144002020	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.04603	-118.25236	PC for energy and  power. Core and shell only with existing 120/240V, 800A Service. total area 9713 sq ft. B #17016-10000-07254	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25581	16041-10000-09053	611 W EXPOSITION BLVD	90089	9	118-5A201  46	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.01843	-118.28272	PC for energy only to an existing cafe at usc school of business. Remodeling cafe adding new lighting and power. Total sq ft = 1825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25582	15041-20000-14726	8924 N LANKERSHIM BLVD	91352	6	195B169   187	2631016028	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	34.23168	-118.38758	Plan check for Title 24 only. Project site is a parking lot. Total outdoor lighting area = 50,150 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25583	15041-20002-13036	16822 W GLEDHILL ST	91343	12	198B133   149	2687011009	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2015 12:00:00 AM			PC Approved	08/26/2015 12:00:00 AM	ADDRESS	34.24187	-118.49892	Changes to an approved set of plans. Changing total number of modules from 26 to 24.(((Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25584	18041-20001-42767	3523 S CENTINELA AVE 2-7	90066	11	114B153   477	4246006001	[Q]C1-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.00999	-118.43857	10/10/19CHANGES TO APPROVED SET DELTA 2 ONLY CHANGES TO CIRCUIT BREAKER SIZE.<<<PLAN CHECK FOR POWER ONLY FOR UPGRADE OF EXISTING 600A 120/240 SINGLE PHASE SERVICE TO 800A 120/240 SERVICE. ALL EXISTING PANELS TO REMAIN AND RECONNECTED TO NEW SERVICE. (NO NEW LOADS TO BUILDING)>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25585	19041-10000-09541	330 S HOPE ST 2ND FLOOR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			Corrections Issued	03/18/2019 12:00:00 AM	ADDRESS	34.05319	-118.25252	05/03/2019Void- PLAN CHECK FOR T-24 HAS BEEN COMBINED TO 19041-10000-12111. _____________________________________________________________T-24, PLAN CHECK FOR ENERGY ONLY. PROPOSED CHANGE OF USE 8,717 USF OF OFFICE SPACE TO A BAR, GYM WORK AREA; NO OUTDOOR DINING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25586	16041-30001-19985	23958 W STRATHERN ST	91304	12	189B089   131	2020013040	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.21489	-118.65005	EXPEDITE PER APPLICANT.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25587	18041-10000-05576	1728 W LOMITA BLVD	90717	15	036B193   950	7410016021	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	33.79764	-118.30846	PC for T24 only for McDonalds TI. Installing new lighting. Total 2743sqft. B# 18016-10000-04701.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25588	15041-20000-43189	20720 W VENTURA BLVD 3RD FLR	91364	3	171B109    80	2166014013	(Q)CR-1VLD, (Q)P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Info Complete	12/22/2015 12:00:00 AM	ADDRESS	34.16654	-118.5845	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING 3-STORY COMMERCIAL BUILDING ON THE 3RD FLOOR (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 7267 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25589	15041-10000-42052	2301 E WHITTIER BLVD	90023	14	124-5A221 214	5183027013	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.035	-118.21677	PV1, INSTALL 6.36 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (23) MODULES:SILVEO TRIEX U290 BLACK(1) INVERTER: ABB-PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25590	16041-20000-23114	706 W MANCHESTER AVE Bldg E	90044	9	097-5A207 307	6042002031	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Closed	03/01/2017 12:00:00 AM	ADDRESS	33.95986	-118.26272	Plan check for Title 24 only in existing class room Building E. Total area: 1,032 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25591	17041-10000-28260	12975 N BRADLEY AVE	91342	7	222B145   166	2506003021	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Issued	09/07/2017 12:00:00 AM	ADDRESS	34.30539	-118.46035	PC for power only. Scope includes refurbishing existing building's switchgear and distribution boards. Also refurbishing/replacing distribution sections, breakers, and feeders.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25592	17041-10000-45355	2250 E ALCAZAR ST CSC	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Info Complete	12/18/2017 12:00:00 AM	ADDRESS	34.06307	-118.2	Plan check for T24 only, replace light fixtures on the mechanical room and mehanical air intake. add new AHUs, (1) 100A panel, (1) 225A panel with total load <200A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25593	14041-10000-17992	607 N ARDMORE AVE	90004	13	141B193   872	5521007012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.08196	-118.30186	PV1 9.36KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(2) inverters: {SOLAREDGE SE3800A-US, SOLAREDGE SE3800A-US}]. [(36)modules: {REC {REC 260 PE}}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25594	19041-10000-03199	2012 S PELHAM AVE	90025	5	129B157   742	4321009056	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.04902	-118.42926	PV1. Install 4.874 kW roof mounted PV system. (15) modules with P400 OPTIMIZERS, (1) 5 KW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25595	18041-30000-07504	14006 W RIVERSIDE DR #73	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only in existing space T.I. retail space. Total area: 2046 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25596	18041-10000-19685	2911 W TEMPLE ST	90026	13	139-5A203 452	5156014011	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village	YES	1958.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.07447	-118.27879	Energy plan check for a TI OF EXISTING 2-STORY OFFICE/WAREHOUSE BUILDING. Scope include new lighting and equipment. Total area is 6500-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25597	19041-20000-07398	2100 W 3RD ST Ste 400	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.06281	-118.2731	OSHPD-3 medical clinic tenant improvement. Total lighting area = 14,572 sq. ft.Note: Building application has been generated under 19016-10000-02757	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25598	17041-20000-13555	1990 S BUNDY DR 270	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.03419	-118.45559	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 4189 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25599	15041-10001-36820	164 S HUDSON AVE	90004	4	138B185   380	5515005006	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.07199	-118.33325	RSES expedited plan check per applicant request.  PV1.  Install 9.765 kW DC roof-mounted, utility-interactive PV system.  (31) LG 315N1C-G4 modules and (1)  SolarEdge SE-10000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25600	17041-20000-00877	1503 E VENICE BLVD	90291	11	111B149  1333	4242033001	[Q]R4-1XL	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	33.99661	-118.44832	Plan check for Title 24 only. Project site is an existing church. Project scope is a tenant improvement. Total lighting area = 2,715 sq. ft.Note: Building application has been generated under 16016-30000-13719	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25601	17041-20000-27508	1123 N HYATT AVE	90744	15	033B209   570	7423027019	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	33.78582	-118.25436	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (16) modules. Stadard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25602	14041-10000-23285	7407 W COASTAL VIEW DR	90045	11	099B157   530	4114035001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/26/2016 12:00:00 AM	ADDRESS	33.96452	-118.42662	Installation of roof mounted solar system.  System size = 7.6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25603	15041-20000-09652	20022 W VENTURA BLVD	91364	3	174B113   466	2166001020	C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.17141	-118.56915	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 3026 SQFT, EMERGENCY LIGHTING EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25604	18041-10000-05666	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	08/30/2022 12:00:00 AM	ADDRESS	33.76094	-118.29308	**Permit fee is zero dollar due to AB 1414 / SB 1222**PC for 478kW(AC)/ 523 kW AC-CEC/ (590.72kW(DC). PV solar system in Target building. Installing 1664 modules ), 8 central inverters and 800A distribution boards.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25605	15041-10000-00578	3535 S BENTLEY AVE	90034	5	117B157   238	4252005007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.01906	-118.4202	PV1.  Install 5.94 kW rooftop-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25606	16041-10001-14602	18777 W EDLEEN DR	91356	3	168B121   223	2176026016	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.15691	-118.54114	07/05/16Changes to an approved set. Changes include relocating the PV production meter, AC disconnect and a 400A main service board.Note: Permit paid under PCIS#16041-10000-14602((((PV1 SYSTEM, GROUND MOUNT 10KW DC, CONNECTED TO SINGLE FAMILY DWELLING. 42MODULES.(42)HANWHA Q-CELLS Q.PRO-G3G3 250(1)INVERTER-SMA AMERICA SB 9000TL-US-12-240V	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25607	17041-10000-31445	2029 S CENTURY PARK EAST SUITE 1250	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR (E)OFFICE T.I. (SUITE 1250) IN A HIGH RISE BUILDING FOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW CIRCUITS, LIGHTS, EQUIPMENT AND RECEPTACLES.TOTAL AFFECTED AREA 4375 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25608	14041-10000-26902	18541 W VINCENNES ST 1-59	91324	12	198B125   156	2763035006	R3-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Apartment			09/30/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.24104	-118.53737	PV2. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 24,400W DC.(80) CANADIAN SOLAR CS6X-305M(1) FRONIUS IG PLUS 11.4-3(1) FRONIUS IG PLUS 10.0-1	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25609	16041-10000-09811	8041 W WORLD WAY WEST	90045	11	090B157    96	4129026910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Closed	11/13/2017 12:00:00 AM	PIN	33.94111969	-118.42968741	PC FOR POWER. NEW SERVICE 2500A TO SERVICE NEW GROUND SERVICE EQUIPMENT AND FUTURE PRE-CONDITIONED AIR BATTERY CHRGER EQUIPMENT.Attention: Customer should be charged for an additional pc fee 2 panels and possibly 7 branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25610	15041-10000-01648	7891 N DEERING AVE	91304	3	189B105   348	2109001008	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.21354	-118.59518	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. Total lighting area that is in the scope of work = 2,050 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25611	15041-20000-44062	10421 N KEOKUK AVE	91311	12	207B113   271	2707016004	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.26026	-118.57429	Plan check for PV roof mounted system. System size: 12.0kWac with  40 modules and 2 inverters (6.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25612	17041-20000-32187	17142 W OTSEGO ST	91316	5	171B133   493	2258011010	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.16356	-118.50716	"""0$ permit fees due to senate bill 1222""Plan check for solar pv system, roof-mounted on SFD.(64) 320W AC modules. 20.48kW ungrounded system."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25613	18041-10000-36868	1125 S CRENSHAW BLVD	90019	10	129B189   236	5082026007	C2-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM			Reviewed by Supervisor	10/01/2018 12:00:00 AM	ADDRESS	34.05233	-118.32448	FULL PLAN CHECK FOR POWER AND ENERGY FOR - NEW (5) STORY, 49,948 SQ. FT. OF MIXED USE DEVELOPMEN-- RESTAUREANT, RETAIL, ADULT CLASS, OFFICE, EXHIBITION <<CORE & SHELL>> & 3 UNIT APARTMENT.  <<ALL COMMERCIAL INTERIOR TI UNDER SEPARATED PERMIT>> SERVICE SIZE = 300A AT 120/208V. TOTAL AFFECTED AREA = 92212 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25614	14041-10000-04025	636 N LA BREA AVE	90036	5	141B181   702	5525017002	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Public Safety Only			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Closed	08/28/2014 12:00:00 AM	ADDRESS	34.08285	-118.34386	New fire alarm for a 3 story Bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25615	18041-10002-41079	770 S GRAND AVE STE A	90017	14	129A209   223	5144012061	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.04603	-118.25748	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. <<<NEW RESTAURANT IN EXISTING MIXED USED BUILDING. FIRST TIME TENANT. PLAN CHECK FOR POWER & ENERGY. 3,053 SQR FT.  BUILDING PERMIT: 18016-10000-32133>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25616	10041-20000-20731	9820 N TOPANGA CANYON BLVD B and C	91311	12	201B101   171	2746017031	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM			PC Approved	10/19/2010 12:00:00 AM	ADDRESS	34.24905	-118.60582	T.I. to existing space.  Install general/emergency lighting.  Plan check for energy only.  NOTE: Permit under separate application 10041-90000-20452.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25617	16041-20002-21678	20557 W DEVONSHIRE ST	91311	12	204B109   127	2707013030	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM			PC Approved	04/18/2017 12:00:00 AM	ADDRESS	34.25742	-118.5812	Revision to approved set of plans.  Changes to lighting system details (fixture models, quantities, layout).  Delta-2 revisions only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25618	10041-20000-16431	21900 W BURBANK BLVD #210	91367	3	174B105    46	2146007120	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	ADDRESS	34.17189	-118.60404	energy plan check #210 for reception area	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25619	16041-30001-00495	13224 N MIRA MAR DR	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	ADDRESS	34.31307	-118.40434	Expedite fees only.     Addition of roof mounted solar PV array to existing solar PV system.  Total system size = 7.2 kWac (3 kWac new + 4.2 kWac existing).  Two inverters total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25620	19041-10001-44049	4139 N RHODES AVE	91604	2	165B165  1061	2367010034	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.14608	-118.40315	EXPEDITED PER APPLICANT REQUEST. NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 12.48 KW DC/ 10KW AC, WITH A SOLAR EDGE CENTRAL INVERTER (SE10000H-US), 39 MODULES (LG320N1K), 39 SOALREDGE P320 OPTIMIZERS CONNECTED TO A 125A SUBPANEL .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25621	19041-10000-35547	1515 N VERMONT AVE	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood	YES	1912.01	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.09867	-118.29207	FULL PLAN CHECK FOR AN INTERIOR TENANT IMPROVEMENTS (KAISER PERMANENTE) AT THE FIRST FLOOR OF AN EXISTING 8 STORY MEDICAL OFFICE BUILDING (NON-OSHPD). TOTAL AFFECTED AREA IS 11736 SQ.FTPROJECT DOES NOT INCLUDE EMERGENCY GENERATOR LOAD (NO CHANGES)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25622	14041-20000-14909	17401 W OSBORNE ST	91325	12	195B129   122	2768020001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.23354	-118.51382	New roof mounted PV system with optimizers and transformerless inverter.  Total system size 6.8KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25623	14041-20001-22623	19801 W NORDHOFF PL Unit 111	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Approved	09/08/2014 12:00:00 AM	ADDRESS	34.23568	-118.56464	THIS APPLICATION IS FOR PLAN CHECK ONLY. NO PERMIT TO BE ISSUED. PLAN CHECK FOR FIRST TIME ELECTRICAL INSTALLATION IN TENANT SPACE. POWER ONLY. Plan check for commercial warehouse/office tenant space.PC FOR POWER. ORIGINAL PLAN CHECK FOR ENERGY UNDER ORIGINAL APPLICATION. THIS IS POWER PLAN CHECK FOR ENTIRE TI. SCOPE TO COVER 600A SERVICE AND ALL CONNECTED LOADS. DUE TO DEPARTMENT ORDER, PERMIT WILL EXPIRE 30 DAYS FROM DATE OF ISSUANCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25624	16041-10009-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM			PC Approved	08/01/2019 12:00:00 AM	ADDRESS	34.23567	-118.5584	PCHANGES TO PERMITTED SET OF PLANS-BULLETIN 38ATTACHED TO THE PLANS IS A LIST OF CHANGES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25625	17041-20001-11993	341 S BERENDO ST	90020	10	135B197   396	5502006024	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	04/22/2017 12:00:00 AM	ADDRESS	34.06786	-118.29431	expeditepv2install roof mounted pv system sized 32kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25626	15041-20000-24645	703 N WESTERN AVE	90038	13	141B193   569	5535017007	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	PIN	34.08373106	-118.30949282	PLANCHECK FOR T24 ENERGY.  FURNITURE STORE. 1581 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25627	10041-20000-23283	18521 W VENTURA BLVD	91356	3	174B125   574	2160007026	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM			PC Approved	11/19/2010 12:00:00 AM	ADDRESS	34.16931	-118.53678	energy plan check existing permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25628	15041-10000-43957	17383 W SUNSET BLVD A-205	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	PC for energy only to existing office space. Adding new lighting and power. Total sq ft = 2265	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25629	17041-10000-02543	7501 W IMPERIAL HWY	90045	11	087B157    12	4129026913	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Info Complete	08/01/2018 12:00:00 AM	ADDRESS	33.93123	-118.42826	Plan check for Hazardous Location at LAX Fire Drill Traning Facility Recommisioning.  Fuel and water pump use to pump water and fuel to Fire Pit for Fire fighter training. The combination of water and fuel will come from fire pit to water treatment facility(Equipment Pad).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25630	18041-10000-45137	301 W 49TH ST 1-30	90037	9	111A203   207	5110016027	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	01/27/2023 12:00:00 AM	ADDRESS	33.99842	-118.27887	Full plan check for a change use from motel to temp' housing. Scope include new lighting and equipment with a total of 1474 SQ FT with one new 600-Amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25631	15041-10000-05561	1645 W SEPULVEDA BLVD # 9	90501	15	045B193   440	7347017025	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.81672	-118.30758	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 1480 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25632	16041-20000-14663	16625 W ARMINTA ST	91406	6	189B137    29	2205009031	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.21497	-118.49561	$0 permit fee due to State Senate Bill SB 1222.  PV2.  INSTALL ROOF MOUNTED PV SYSTEM SIZED 40KW INTERCONNECTED TO UTILITY GRID.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25633	19041-20000-04355	9740 N SALOMA AVE	91343	7	201B149   392	2650008010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.24756	-118.4575	PV1 ROOF MOUNTED PV SYSTEM WITH SYSTEM SIZE OF 5 KWAC / 5.94 KWDC. (18) MODULES WITH (18)OPTIMIZERS P400 AND (1) INVERTER 5 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25634	17041-10001-40437	16951 W AVENIDA DE SANTA YNEZ	90272	11	138B117   237	4431004050	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM			PC Approved	03/11/2019 12:00:00 AM	ADDRESS	34.07338	-118.5609	DELTA 1 SUPPLIMENTAL PC FOR AN APPROVED SET. RELOCATION OF EQUIPMENT ONLY.  ((((PC FOR ENERGY STORAGE, POWER WALL 2.BATTERY RATED AT 5.8KWac (13.5KWh)SCOPE INCLUDES ADDITIONAL NEW LOAD CENTER (200AMP)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25635	15041-10000-31521	3121 S MAIN ST	90007	9	118-5A205  44	5122005029	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	PIN	34.02045256	-118.27191839	REMOVE EXISTING HID LIGHITNG FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25636	16041-20000-42168	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	33.97954	-118.41361	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDOR. 2ND FLOOR. 243 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25637	17041-20001-17780	4742 N RONMAR PL	91364	3	168A111    24	2174014021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.15634	-118.58033	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25638	16041-20000-07941	2112 1/2 N JOHNSTON ST	90031	1	136-5A223  71	5210021014	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.06935	-118.21014	PV1.  Installation of 4.2 kW PV system.  (13) modules with (1) central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25639	15041-10000-22992	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	FULL PC, TI TO AN EXISTING RETAIL BUILDING 4 STORIES. SCOPE OF WORK INCLUDES NEW LIGHTING ON THE 1, 2, AND PARTIAL 3RD FLOOR. CONNECTED LOAD OVER 400A. TOTAL SQ. FT. = 209772    PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25640	18041-20001-24004	11840 W FOOTHILL BLVD Unit #H	91331	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM			PC Approved	07/09/2018 12:00:00 AM	ADDRESS	34.27349	-118.39431	07/09/2018 Changes to an approved set of plans. Changes have been made to the lighting floor plans. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****TI in an existing commercial area in Unit #H (La Michoacana Emerita Ice Cream). Existing Service, Existing Panels and Existing lights to remain. First time tenant. Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25641	18041-20001-00586	2044 S LINNINGTON AVE	90025	5	129B157   291	4317012048	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.05199	-118.42256	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.6 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25642	18041-10000-27019	600 S PIER A ST	90744	15	024B205   671	7440014904	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	33.7626	-118.26693	*Zero dollar fee due to AB-1414/ SB-1222* NEW PV SYSTEM MOUNTED ON CARPORTS WITH 2080 PV MODULES AND 23 INVERTERS WITH 480 VOLT OUTPUT. SYSTEM SIZE  904.8 KWDC/690KWAC<<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03434	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25643	17041-20001-41963	13150 W OSBORNE ST	91331	7	201B161   648	2626005029	[Q]C1.5-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Issued	06/21/2018 12:00:00 AM	ADDRESS	34.24708	-118.4189	Renovation of (E) convenience store.  Plan check for energy only.  Supplemental permit fees per inspection correction notice. (((3 new underground electrical receptacleand relocating existing cashier circuits)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25644	17041-20001-28136	1420 N DETROIT ST	90046	4	147B181   810	5548017041	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	ADDRESS	34.09688	-118.34506	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar system on apartment building.32.4kW ungrounded system (9+9+14.4).(98) 395W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25645	13041-20000-03979	839 N LA CIENEGA BLVD	90069	5	141B173    72	4337002044	[Q]C4-2D	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.0864	-118.37669	Change to lighting and receptacles, new panel.  Load is less than 400 amps.  Existing retail space.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25646	12041-20000-05989	11250 W OLYMPIC BLVD 2nd Floor	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.03831	-118.44057	T.I. to existing building 2nd floor of Pet Smart.  Install 1200A panel, subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25647	15041-20000-35603	1834 N AVENUE 52	90042	14	157-5A225 156	5479017008	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.12612	-118.20204	PV1. ROOFMOUNTED SYSTEM: 1 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25648	16041-10000-21386	11755 W WILSHIRE BLVD STE 1350	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM			PC Approved	07/15/2016 12:00:00 AM	PIN	34.04869377	-118.46238681	T-24, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN OFFICE BUILDING. TOTAL SQ. FT. 392.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25649	18041-20001-15448	5724 N JUMILLA AVE	91367	3	174B117   139	2153019016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM			PC Approved	08/20/2018 12:00:00 AM	ADDRESS	34.17515	-118.5638	8/20/2018change of word description to :11.4KW AC and 12.07KW DC CEC.Department error $0.00 fee	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25650	18041-10000-04827	3825 S 2ND AVE	90008	10	117B189   734	5034017021	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.01734	-118.31947	PC FOR ROOF MOUNTED PV FOR SFD. SYSTEM SIZE 11.8KWDC/ 11.4KWACSCOPE INCLUDES 40 MODULES WITH OPTIMIZERS AND CENTAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25651	19041-10000-30019	601 S FIGUEROA ST 23RD FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM			PC Approved	08/02/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I. FOR FULL 23RD FLOOR, WORK TO INCLUDE NON-LOAD BEARING PARTITIONS, MILL WORK, CEILING, LIGHTING. (NO CHANGE OF USE)PLAN CHECK IS FOR POWER AND TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25652	10041-10000-22265	213 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04917	-118.22697	Solar voltaic system installed on the roof of the building.  Consists of 5 modules, 5 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25653	19041-20000-07691	9048 N GULLO AVE	91331	6	195B153    70	2640006028	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.23455	-118.43309	PV1.  Install 4.68 kW DC / 4.07 kW AC roof mounted grid tied PV system.  (13) modules with 3.8 kW rated string inverter.  (E) 4.8 kW PV system on site.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25654	11041-20000-16642	16437 W VENTURA BLVD	91436	5	168B137   804	2260009043	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM			PC Info Complete	08/08/2011 12:00:00 AM	ADDRESS	34.15766	-118.49151	enegy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25655	18041-10001-20363	4121 S AVALON BLVD	90011	9	115-5A207 508	5113005031	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2283.20	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.00857	-118.26555	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25656	12041-10001-26028	12751 W MILLENNIUM A-B	90094	11	102B161  1175	4211033020		West Los Angeles				2756.01	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	33.9761	-118.41651	New methane mitigation system for new mixed used building. Building A and Building B with common subterranean parking garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25657	16041-10001-39848	3084 S MOTOR AVE	90064	5	123B161   498	4316007009	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM			Reviewed by Supervisor	08/02/2017 12:00:00 AM	ADDRESS	34.03423	-118.41021	PC FOR CHANGES TO APPROVED PLANS. CHANGES NOTED DELTA 2 AND 3. REVISED DEVICE COUNT, ADDED SOME MORE DETECTORS AND MODULES. UPDATED FLOOR PLANS, BATTERY CALCS AND ADDITONAL RPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25658	14041-10000-28922	730 S ALAMEDA ST	90021	14	123A215   224	5166032037	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.03268	-118.23767	Plan check for energy for 633 sq. ft. industrial cold storage room used for banana ripening.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25659	18041-10001-32631	736 S CERES AVE	90021	14	124-5A213  69	5146004025	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.03707	-118.24395	RESTAMP TO REPLACE LOST APPROVED PLANS. CLEAN SET PROVIDED TO MATCH APPROVED SCANED COPY OF THE ORIGINAL.Power plan check for a new 600-Amp service 120/240v 3-phase 4-wire.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25660	13041-10000-08794	735 S BROADWAY	90014	14	127-5A209  71	5144014031	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.04448	-118.2543	FIRE ALARM FOR MIXED USE BUILDING. 74 DEVICES, 1 FIRE ALARM CONTROL PANEL, AND 1 ANNUNCIATOR. NOT A HIGHRISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25661	15041-10000-30923	17120 W VANOWEN ST	91406	6	180B133    24	2230011901	[Q]PF-1XL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.19363	-118.50653	Power plan check for service upgrade (5000-Amp, 480/277V 3phase 4-wire) and new equipment added for supporting new data center connected as a whole package load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25662	19041-10000-32973	961 S MARIPOSA AVE	90006	10	132B197  1194	5078002032	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/07/2019 12:00:00 AM	ADDRESS	34.05388	-118.29907	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25663	17041-20001-39721	10337 W CARIBOU LANE	90077	5	150B153   759	4380021018	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	PIN	34.10504083	-118.44431592	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.355 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25664	16041-10000-38863	18230 W LOS ALIMOS ST	91326	12	207B125   245	2715009020	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.26524	-118.53097	ROOF MOUNTED PVPC FOR PV SYSTEM TOTAL OF 3.4 KW AC USING TOTAL OF 16 MODULES. AND MICROINVERTERS ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25665	16041-30000-36927	9620 S AIRPORT BLVD	90045	11	093B169   171	4125023034	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	33.94842	-118.38574	Plan check for power and Title 24.  T.I. to common area (lobby, restaraunt, bar, and restrooms of existing Renaissance hotel).  New lighting and receptacles.  Project location is classified as type A occupancy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25666	19041-10000-13712	19191 S VERMONT AVE STE 925	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	Energy plan check for an office T.I located in the 9th floor of a high rise building. Scope includes new lighting and equipment with a total area of 2,302-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25667	14041-10000-07187	12730 W RAYMER ST STE B	91605	2	186B161   550	2324004001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.20365	-118.40977	T24, REMOVE EXISTING HID LIGHT FIXTURES WITH NEW FLORESCENT LIGT FIXTURES. TOTAL AREA 10917 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25668	11041-10000-26179	500 S VIRGIL AVE	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	07/30/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	T.I. to an existing Medical Radiology Clinic.  New lighting and circuits.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25669	10041-20000-17866	1100 S ABBOT KINNEY BLVD	90291	11	108B145  1110	4238003005	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	33.99167	-118.47055	Plan check T-24 energy for existing retail store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25670	13041-10000-00981	380 WORLD WAY SPACE T44B	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 664 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE  CONCESSION (Chaya).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25671	14041-10000-23109	784 E 12TH ST	90021	14	123A211    88	5132012061	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.03233	-118.25093	PLANCHECK FOR T24 ENERGY. REPLACE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 468 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25672	18041-10000-07233	200 E BAUCHET ST	90012	14	133-5A215 236	5409015017	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	05/17/2021 12:00:00 AM	ADDRESS	34.05873	-118.23498	FULL PLAN CHECK OF A NEW 4-STORY DATA CENTER BUILDING (LA3).  (4) New services at 600A 34.5 k; (4) 34.5kV/12.47kV xfrmr, (3) medium voltage dist. boards; (6) medium voltage unit substations; other equipment are 600V or less.   18010-10000-00872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25673	14041-20000-34972	7740 N SAUSALITO AVE	91304	12	189B101   716	2013014003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Expired	01/11/2017 12:00:00 AM	ADDRESS	34.21133	-118.61554	PV1. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.14 KW(28) KYOCERA KU2556XCA(1) ABB PVI-6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25674	13041-20000-25404	8378 N OUTLAND VIEW DR	91352	2	192B177   426	2404016013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.22289	-118.35653	pv1 single family dwelling total system size 3.6 kw ac using 19 modules. transformerless inverter nonstandard plan. 2 strings	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25675	17041-20000-09814	939 S THAYER AVE	90024	5	135B153   391	4360017028	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.06468	-118.43397	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.36 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25676	18041-10000-05327	20355 W CORISCO ST	91311	12	198B113   183	2748001044	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.2356	-118.57776	REPLACE OUTDOOR AND INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25677	19041-20000-32310	6080 W CENTER DR 10th floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	T24 PLAN CHECK FOR EXISTING HIGH RISE 10TH FLOOR RESTROOM. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 540 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25678	18041-20000-43674	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.02174	-118.39786	addition of ev chargers with energy management system to an existing commercial building.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25679	19041-20000-29056	690 S ALAMEDA ST	90021	14	124-5A215  52	5164023025	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.03528	-118.2384	Plan check for Title 24 energy only in existing space Tenant Improvement, Total area: 1100 sq ftB#19016-20000-21851	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25680	13041-10000-11113	4082 S LINCOLN BLVD	90292	11	108B149  1565	4230002012	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	33.98861	-118.44578	TI TO EXISTING RETAIL SPACE. TOTAL AREA 4038 SQ FT. CHANGE OUT OF FIXTURES TO MORE ENERGY EFFICIENT FIXTURES. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25681	12041-10000-19464	177 S LA BREA AVE #G4	90036	5	138B181  1180	5513019039	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	PIN	34.07159263	-118.34436557	FIRST TIME TENANTS IN UNIT #G4. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25682	17041-10000-14692	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for Title 24.  Temporary work includting new lighting and receptacles in office area.  Total area = 4,676 sq. ft.     Original permit #16041-10000-25972	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25683	17041-10000-17002	7329 S BROADWAY	90003	9	102B201  1196	6031004030	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM			PC Approved	05/22/2017 12:00:00 AM	ADDRESS	33.97293	-118.2785	PC for T24 only TI for new lights and receptacles in art studio. New connected load under 400 A with total area of 1950 sqft. Building 16016 10000 28038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25684	13041-10000-13755	5000 N LANKERSHIM BLVD	91601	2	171B173  1229	2353009015	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.16117	-118.37219	permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. TI-RETAIL TO RETAIL. LESS THAN 400A PER APPLICANT. citizen co. tenant improvement	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25685	12041-10000-20225	2535 E 12TH ST	90021	14	120A219    28	5168004001	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM			PC Approved	08/27/2012 12:00:00 AM	PIN	34.02266563	-118.22644618	Plan check for energy and emergency lighting. Ground floor + mezzanine. 7887 sqft. Studio of Architecture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25686	16041-10000-09086	900 W WILSHIRE BLVD 69th floor	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	First time tenant Full PC to a multi used high rise bulding. Scope of work is on the 69th floor with total area of 13,110 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25687	14041-20000-17811	12426 W VALLEY VISTA WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.30811	-118.40451	6.63KW PV1 roof-mounted system with (26) Trina Solar TSM255  modules and one Power-One Aurora PVI-6000 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25688	13041-20002-35351	3725 N BEVERLY RIDGE DR	91423	4	162B149   454	2274016008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.13853	-118.44734	((((changes to approved set of plans. changes clouded))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.8 KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25689	18041-10000-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.26056	-118.35206	NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 11.0KWAC/ 16.8KWDC (OPTIMIZERS)SCOPE INCLUDES 42 MODULES WITH OPTIMIZERS AND 2 CENTRAL INVERTERS. EXSITING SERVICE AT 600A  120/240 NEW ESS UNDER  10003 SUPP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25690	14041-10000-07168	2748 W 8TH ST 107	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.05747	-118.28552	PLAN CHEK FOR ENERGY AND POWER.CHANGE OF USE OF EX 3 RETAIL TENANTS TO RESTAURANT & COMBINE WITH EXISTING RESTAURANT. TOTAL AREA 5710 SQ FT.BUILDING APPLICATION # 1316-10000-15644.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25691	16041-20000-28847	3307 N DERONDA DR	90068	4	157-5A191  11	5582024003	RE9-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.12776	-118.31952	"PV1.  Install 10.79 kW roof mounted utility-interactive PV system.  (33) AC modules with (1) subpanel.Investigation fee due: ""COMPLY WITH DEPARTMENT ORDER effective date11/30/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25692	14041-20000-17356	801 S FIGUEROA ST	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.04789	-118.26153	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING.  EXISTING HIGH RISE BUILDING NEW LIGHTING AND NEW BRANCH CIRCUITS ON EXISTING PANELS.  WORK TO BE DONE ON THE ELEVENTH FLOOR ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25693	18041-20000-38172	10965 W ELINDA PL	91352	7	201B173   373	2538013011	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.24456	-118.36981	Plan check for PV roof mounted system, system size: 17.49KW DC, 16.086KW AC with 53 PV Modules and 53 Microinverters connected to 225A Panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25694	19041-10000-17557	2636-2638 N PASADENA AVE	90031	1	139-5A221 100	5205021013	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.07754	-118.2152	pc for energy only, scope of work 1009 SF. Change of use from duplex/store building to duplex/office building by adding  (N) partitions and openings at roof for (N) skylights. Reinforce existing foundation with (N) pad footings. No change in building footprint and building height. 1 of 2. See comments.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25695	12041-10000-27815	16860 W SAN FERNANDO MISSION BLVD # 16860	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.27121	-118.49994	TENANT IMPROVEMENT AT THE GNC STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25696	17041-20001-29979	23044 W ERWIN ST	91367	3	177B097   285	2039009018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.18266	-118.62917	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.9 kWac and consists of (39) modules, (39) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25697	19041-10001-10099	18781 W BRAEMORE ROAD	91326	12	216B121   229	2820016004	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Issued	06/05/2019 12:00:00 AM	ADDRESS	34.28968	-118.54229	Changes to an approved set of plans, changes under clouded area delta C addition of new sub panel.  ________________________(ePlan) New roof-mounted solar PV system 7.6 kW AC. Instal 37 modules, 37 power optomizers,  and 1 inverter. System conect to (E) 200A MSP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25698	18041-10002-08941	11541 W COOLIDGE PL	90066	11	117B153   175	4250017026	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			Reviewed by Supervisor	03/19/2018 12:00:00 AM	ADDRESS	34.0198	-118.43296	FEES FOR TESLA BATTERIES. PV 1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND TESLA BATTERIES. (46) MODULES, (2)  6.6, 3.8 INVERTERS, AND NEW LOAD CENTERS. TOTAL PV SYSTEM SIZE IS 11.895 KWDC/10.4KWAC AND BATTERY SYSTEM SIZE IS 11.6KW/ 27KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25699	13041-20000-32611	7700 N BABCOCK AVE	91605	2	189B161  1116	2307002016	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.21055	-118.40632	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.2 KW AC USING 23 MODULES. 2 CENTRAL INVERTERS TRANSFORMERLESS, NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25700	17041-10000-38194	6857 N RANCHITO AVE	91405	2	183B153   926	2216018031	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.19555	-118.43575	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.52KWac.(11)AC MODULES-SUNPOWER SPR-X22-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25701	18041-10000-12462	4501 W COLORADO BLVD	90039	13	162B205    19	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.14246	-118.2705	PLAN CHECK FOR TITLE 24 ONLY FOR TENANT IMPROVEMENT  FOR 2ND FLOOR FOR RENOVATION OF THAWING AND GOWN PICK UP ROOMS AND CUT AND PATCHING WORK. TOTAL AFFECTED AREA 1645 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25702	19041-20000-10407	10701 W WALNUT DR	91040	7	201B177    95	2542014020	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.25009	-118.36265	Plan check for PV roof mounted system, System size: 11.52KW  with 36 PV Modules and 1 inverter(11.45KW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25703	10041-10000-13989	3335 S FIGUEROA ST USC3	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	FIRST TIME TENANTS ON PORTION OF THE 1ST FLOOR IN USC (UNIVERSITY GATEWAY, SUITE # USC3).  CORE & SHELL APPROVED UNDER A DIFFERENT PERMIT NUMBER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25704	18041-20000-01781	5525 N CASE AVE	91601	2	174B173  1206	2350003059	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			01/17/2018 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	02/15/2022 12:00:00 AM	ADDRESS	34.17084	-118.37214	New 98-unit apartment building.  2500A 208Y/120V 3ph-4w service.Building permit submitted under 17010-30000-02978.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25705	14041-10000-09920	5791 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	33.93414	-118.3839	fees under inspection. PERMIT to be pulled at EPC counter only. Plan check for energy only. emergency lights, 2 story, less than 400A. BLDG# 14014-10-01048: MEZZANINE ADDITION WITH 2 ACCESS STAIRWAYS FOR ADDITIONAL STORAGE SPACE INSIDE (E) WAREHOUSE.  (AREA OF MEZZ. = 4700 S.F.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25706	17041-10000-44222	816 W 8TH ST	90017	14	129A209   134	5144021029	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.04747	-118.26066	New restaurant. Change of occupancy. EPC for power and energy. B# 17016-10000-31991.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25707	17041-20000-29671	9031 N LURLINE AVE	91311	3	195B109   477	2780001063	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.23463	-118.58443	ti to an existing warehouse.  adding new lighting new controls to existig panels.  plan check for energy only.  total square footage 5500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25708	15041-20001-06182	14177 W LA RUE ST	91340	7	210B153   407	2616004023	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM			PC Approved	04/03/2015 12:00:00 AM	ADDRESS	34.27315	-118.44246	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. POI TO NEW SUBPANEL. 3 STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25709	19041-10000-23787	9800 S LAUREL ST	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Issued	06/20/2019 12:00:00 AM	ADDRESS	33.94799	-118.23082	Plan check for a fire alarm system located in a single story building. Scope includes (1) fire alarm panel and  (10) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25710	18041-20000-15448	5724 N JUMILLA AVE	91367	3	174B117   139	2153019016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.17515	-118.5638	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25711	12041-10001-20212	1517 N FOREST KNOLL DR	90069	5	147B169   601	5558009031	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.09839	-118.38032	Revision to the approved plan. Change of subpanel for the PV system. Plan check for the change. (((((((((((((Plan check for new 11.76KW roof mounted photovoltaic system. Single family dwelling.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25712	11041-10000-27447	10800 W PICO BLVD #318	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM			PC Approved	12/27/2011 12:00:00 AM	ADDRESS	34.04054	-118.4272	TI IN AN EXISTING QUICK SERVICE RESTAURANT(STOVE OVEN) INSIDE THE FOODCORT. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25713	19041-20000-24497	17631 W MAYALL ST	91325	12	204B129   560	2734012050	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.25409	-118.51883	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS KW DC/7.6 KW AC. SCOPE OF WORK INCLUDES (28) SILFAB PV MODULES WITH P320 OPTIMIZERS AND A SE7600H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25714	10041-20000-15655	6061 N TOPANGA CANYON BLVD	91367	3	177B101   111	2146025005	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM			PC Approved	08/11/2010 12:00:00 AM	ADDRESS	34.18066	-118.60615	Revision to approved plan  and existing permit # 10041 20000-13590. Change was to show power plan as installed per inspector request. Plan check T-24 Energy (general/emergency) lighting for existing Chevron  gas station.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25715	15041-20000-28494	12405 W OXNARD ST	91606	2	177B165   655	2333011018	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			08/28/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.17956	-118.40334	plancheck for power and energy for 17 units 3-stories Type VA (R2 occupancy) apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25716	18041-10000-18494	15339 W SATICOY ST	91406	6	186B145    35	2222013050	RA-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Issued	05/18/2018 12:00:00 AM	ADDRESS	34.20861	-118.46754	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25717	13041-20001-34012	8420 W MELROSE PL	90069	5	141B173   503	5528017036	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM	ADDRESS	34.08348	-118.3741	Changes from previously approved plans.  Change include additional of emergency lighting and switches.Plan check for energy only.Note: No change in T-24 calculation.  Permit is under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25718	17041-10000-04658	7020 W MELROSE AVE	90038	5	141B181   668	5525017011	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.0833	-118.34356	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM BEAUTY SALON TO SIT DOWN COFFEE SHOP. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1090 SQ. FT. B#16016-10000-30976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25719	15041-10000-04800	6628 S HOOVER ST	90044	8	102B201   214	6013017001	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	33.97856	-118.28688	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (17) modules, and (1) 125-amp load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25720	18041-20000-03550	20341 W VIA SANSOVINO	91326	12	219B113   264	2701061004	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.29683	-118.57696	Installation of an energy storage system with (E) PV system and 400A 240/120V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25721	18041-20000-06709												Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM				VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25722	15041-20000-35015	3709 S TROUSDALE PKWY #203	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.01851	-118.28672	Plan check for Title 24 for Library. Total area: 167 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25723	18041-20000-22447	14116-14116 1/2 W ERWIN ST	91401	6	177B153   362	2240019011	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			06/15/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.18353	-118.44047	New duplex. Work includes the installation of a 600-amp service which serves (2) buildings: a duplex and a triplex. The triplex can be found under application number 18041-20000-22448.Note: Building application for the duplex can be found under 17010-20000-03093. Building application for the triplex can be found under 17010-20000-03091.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25724	18041-20000-07691	13565 N NORRIS AVE	91342	7	225B141    19	2603013023	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.31762	-118.47394	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25725	17041-10000-01244	7080 W HOLLYWOOD BLVD #600	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.10134	-118.34445	Plan check for Title 24 only in existing high-rise building, office T.I. on #600. Total area: 10,715 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25726	10041-10000-23552	357 S CURSON AVE WEST	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.06858	-118.35526	New service and panel boards for an existing 153 units appartment building. EPC is for power.  The building is located in a Methane Zone.  No existing methane barrier.  The new dwelling unit circuits shall be installed under separate permits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25727	12041-10000-13051	2206 E CESAR E CHAVEZ AVE	90033	14	129A223   108	5183001025	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.04764	-118.21011	Change of use from Retail to Dental office.  Not a state licensed building.  Not checked for OSHPD.  REPLACE LIGHT FIXTURES & INSTALL OUTLETS.  Full Plan Check for Power and Energy.  Permit was previously pulled on a separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25728	14041-20000-15324	544 N CAHUENGA BLVD	90004	4	141B185  1008	5523008027	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.0803	-118.3293	PV1Central Transformerless Inverter Standard Plan.Install a roof-mounted solar array on SFD.(1) Power-One PVI-5000-OUTD-US-A transformerless inverter(23) Renesola Jinagsu JC255M-24/BXH pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25729	15041-10000-36383	2801 W ROWENA AVE #1	90039	4	151-5A207 147	5434030016	C4-1D	Central	Hollywood	Silver Lake	YES	1882.01	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.10772	-118.26482	Reemove HiD light fixures and replace New led fixtures. Sq f t =3120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25730	14041-10000-09913	1150 S BEVERLY DR	90035	5	132A167   103	4330031040	C2-1VL-O, R4-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.05621	-118.39569	HVAC RENOVATIONS AT THE CROWNE PLAZA BEVERLY HILLS HOTEL: INSTALLATION OF CHILLERS ON THE ROOF OF THE BUILDING;REMOVE PTACs IN EACH ROOM AND REPLACE WITH FCU USING SAME CIRCUITS. ; ADDED PUMPS AND BOILERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25731	18041-20003-03184	5636 W BRIARCLIFF ROAD	90068	4	151-5A193 279	5587021013	RE11-1D	Central	Hollywood	Hollywood United	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.10883	-118.31319	04-19-2018 Changes to an apporved set of plans. Changes include revised AC modules model number from SPR-X21-345-D-AC to SPR-X21-360-D-AC. Changes has been clouded. Plan check only. Changes under delta 5 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25732	17041-30001-23165	5654 W MANCHESTER AVE	90045	11	096B169   549	4125018014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Info Complete	07/18/2017 12:00:00 AM	ADDRESS	33.95967	-118.38015	PC FOR RESTAURANT TI FOR TITLE -24, ENERGY ONLY. TOTAL AFFECTED AREA 834 SQ. FTTHIS IS PALN CHECK ONLY!!PERMIT PULLED UNDER MASTERB# 17016-10000-04151 OUTLETS, LIGHTS AND SWITCHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25733	13041-20000-02321	11757 W CHENAULT ST	90049	11	132B145   386	4401013003	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2013 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.05511	-118.46941	Plan check for 1 MW optional standby generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25734	14041-20000-09448	14804 W ORO GRANDE ST	91342	7	219B149   185	2506033049	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.29983	-118.45438	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25735	14041-10000-20344	232 E 2ND ST BLK 8 P D	90012	14	129A213    28	5161024034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	NEW FIRE ALARM SYSTEM.  5-story,  240-unit apartment with retail  and restaurant over garage.  871 DEVICES AND 1 PANELS AND 10 REMOTE POWER SUPPLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25736	11041-10000-08241	785 N VIGNES ST 11TH FLR-12TH FLR	90012	14	132A217   391	5409023940	ADP, [Q]M3-1	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.05606	-118.23248	T.I FOR THE 11TH AND 12TH FLOOR.  CREATING NEW OFFICES.  NO LIGHTING IS BEING TOUCHED.  T-24 PER REQUEST OF INSPECTOR.  T-24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25737	15041-10002-17786	11675 N GLENOAKS BLVD	91331	7	213B157   218	2524022003	C2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.2823	-118.42116	((4/14/2016))TI TO AN EXISTING BUILDING PC FOR POWER AND ENERGY. SERVICE UPGRADE TO 1000AMPS AND NEW PANEL, TOTAL SQUARE FOOTAGE 21367. changes to approved set of plans:  9KVA water heater added  and rating of electrical car chargers reduced to 6KVANOTE.  ORIGINAL PERMIT FEE IS PAID UNDER 15041-10001-17786 (EXPRESS PERMIT)REFERENCE APPLICATION: 15041-10001-1778615041-10000-1778612041-10000-00249	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25738	14041-20001-01357	100 W WORLD WAY T1-Baggage	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	PIN	33.94684048	-118.40128468	(((3/7/2014- CHANGES MADE TO APPROVED SET. INCREASED SIZE OF TRANSFORMER AND ADDED 3 EXHAUST FANS)))New lighting, panels, and 15kva transformer in the baggage handling area of LAX Terminal 1.  FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25739	19041-10000-22230	6053 W CENTURY BLVD 1st Floor	90045	11	093B169   305	4124030902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Closed	08/25/2021 12:00:00 AM	ADDRESS	33.94648	-118.38998	PC FOR Interior TI FOR  fist floor lobby of (E) office building. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 951 SQ.FT. B#19016-10000-09794	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25740	19041-20000-00288	7270 W MULHOLLAND DR	90068	4	156A181   677	5572001008	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.11982	-118.35067	PC FOR PV. SCOPE INCLUDE TWO 48V ENERGY STOARGE LG RESU10. TWO SOLAREDGE SE7600. TWO LOAD PANEL 100A EACH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25741	16041-10000-11589	6251 E CHURCH ST	90042	14	157-5A233 203	5483010049	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Expired	05/04/2018 12:00:00 AM	ADDRESS	34.1244	-118.18115	PV1, INSTALL NEW 4240 W DC ROOF-MOUNTED SOLAR ARRAY ON ASINGLE FAMILY HOME.(16) MODULES: CANADIAN SOLAR CS6P-265P(1) INVERTER: SOLAREDGE SE3800 240V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25742	17041-20001-19005	20326 W KESWICK ST	91306	3	186B113    99	2114002009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.20957	-118.57627	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (33) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25743	13041-10000-30240	633 S MISSION ROAD	90023	14	124-5A219   3	5171015001	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	PIN	34.0373651	-118.22637397	PV2.  Install 287 kW DC roof-mounted solar array, interconnect with existing 1200A switch board.  1157 modules: Orion Series ECO250A-156P-60.  Commercial inverter: Solectria SGI 250$0 permit fee is due to the 2012 Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25744	16041-10000-04020	5601 N DE SOTO AVE	91367	3	174B109   380	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.17126	-118.58861	PC for T-24 only. PV info on the plan is not part of this scope of work. Total area 228,880 sq. ft. All electrical equipments are existing.((NEW CARPORT ADDITION AT THE ROOF OF EXISTING PARKING STRUCTURE TO SUPPORT PHOTOVOLTAIC PANELS))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25745	16041-10000-02240	825 S HILL ST	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			02/04/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	06/24/2021 12:00:00 AM	ADDRESS	34.04392	-118.25657	Proposed  49 story high rise with 490 APARTMENT Units, 4,824 sf of ground floor retail including 2 levels of subterranean parking and 5 levels of podium parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25746	12041-20000-01382	5670 W WILSHIRE BLVD s.500	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	03/20/2012 12:00:00 AM	ADDRESS	34.06222	-118.35208	s.500 office t.i.Energy, emergencyFire/ Life Safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25747	19041-10002-37661	611 N VIRGIL AVE	90004	13	141B197   699	5539025026	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.08215	-118.28702	CHANGES TO APPROVED SET. CHANGING PORTION OF THE SCOPE FROM WALK IN FRIDGE TO STORAGE PLACE. ADDITION OF 1 LIGHT, 1 RECEPTACLE AND 2 CIRCUITS. ALL CHANGES ARE UNDER DELTA 1. (((PLAN CHECK FOR T-24, ENERGY PC ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER FOR A RESTAURANT SPACE. TOTAL SQ. FT. 2445. PERMIT FEES HAVE BEEN PAID FOR UNDER MASTER APPLICATION. 19041-90000-37661______________________________________________________Relocate existing power and add 12 new cricuits. In addition we are adding an additional sub panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25748	14041-20001-03429	5720 N WALLIS LANE	91367	3	174B109   255	2151018030	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.17457	-118.58324	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 8.8KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25749	15041-20001-28720	4346 N MATILIJA AVE 1-22	91423	4	165B153   396	2271017028	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	ADDRESS	34.14985	-118.43389	EXPEDITE FEESPV2 COMMERCIAL ROOFTOP SOLAR. PC FOR PV SYSTEM INTERCONNECT TO HOUSE PANEL ON EXISTING APARTMENT BUILDING. PC FOR 66 MODULES, 2 CENTRAL INVERTERS. TOTAL OF 15.6KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25750	19041-20000-01101	2417 E 25TH ST	90058	14	117A217    61	5168020020	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM	11/03/2022 12:00:00 AM		Issued	11/27/2023 12:00:00 AM	ADDRESS	34.01534	-118.22958	1600A 480Y/277V 3ph-4w service, distribution, power, and lighting for change of use project.  Plan check for power and energy. ***New Nursery*** Building Permit must be issued, before the Electrical Permit can be issued.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25751	16041-10001-31835	1326 W ANAHEIM ST	90744	15	030B201   251	7416002003	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	ADDRESS	33.77893	-118.27909	03/07/17Changes to an approved set of plans. All changes are clouded under delta A. Changes include revising single line diagram and panel schedules. Note: Permit is paid under PCIS#16041-10000-31835	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25752	14041-10000-02890	1518 S FEDERAL AVE MANAGER-OFFICE	90025	11	126B149  1303	4261001029	C2-1VL, R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.04519	-118.45422	T24 PART 6 ENERGY FOR (E) APARTMENT/RETAIL COMBINATION. SPACE CONVERTING TO OFFICE SPACE. NEW CONNECTED LOAD < 400A. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 1186 SQ FT. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25753	10041-10000-02099	747 S WAREHOUSE ST 6th Floor	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM			PC Approved	02/05/2010 12:00:00 AM	ADDRESS	34.03468	-118.23965	Install general lights for conveyor.  Plan check for energy only.   Permit under 10041-30000-01663.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25754	18041-20000-18919	1100 S GLENDON AVE 15TH FLOOR	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	Tenant improvement to (E) commercial highrise office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25755	10041-20000-23262	601 S FIGUEROA ST 40th fl	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	energy plan check 40th fl	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25756	15041-20000-06561	1630 E 108TH ST	90059	15	088-5A213  88	6069001005	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	33.93768	-118.24489	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING STANDARD PLAN. USING 16 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25757	14041-10000-14748	1548 S CENTRAL AVE	90021	14	121-5A211 289	5130014026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.0265	-118.2485	Title 24 only. Total area = 57 sq. ft.New restroom in existing storage space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25758	14041-20000-05462	17907 W TRAMONTO DR	90272	11	126B113    36	4416016058	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.04404	-118.56438	Roof mounted PV system with Microinverter (model M215-60), system size 3.456	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25759	17041-20000-26246	17096 W LASSEN ST	91325	12	201B133   228	2692001030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.24921	-118.50475	pv1install roof mounted pv system sized 27.6kw interconnected with msp.Note: $0.00 permit fee due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25760	16041-20000-34735	4259 N TARZANA ESTATES DR	91356	3	165B117   340	2178005095	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Issued	10/20/2016 12:00:00 AM	ADDRESS	34.14732	-118.56407	12.06 KW GRID TIED PHOTOVOLTAIC SYSTEM.  (36) AC MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25761	14041-10000-30165	8629 N BRADLEY AVE	91352	6	192B173   130	2408018041	M2-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.22492	-118.37184	Title 24 plan check only.  Total area = 9,968 sq. ft.Remove HID lighting and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25762	18041-10000-27607	8454 N SEPULVEDA BLVD	91343	6	192B145   233	2654026015	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Issued	07/24/2018 12:00:00 AM	ADDRESS	34.22425	-118.4675	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25763	19041-30000-07337	1533 N VISTA ST	90046	4	147B181   527	5550013012	R3-1	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	10/20/2021 12:00:00 AM	ADDRESS	34.09899	-118.3512	Plan check for a fire alarm system for a 4-story, 4-unit apartment building. System consists of (1) FACP and (31) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25764	16041-20000-22312	7024 W SHADYGROVE ST	91042	7	201A201   127	2564007001	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.24705	-118.28399	"""0$ permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17KWBUILDING PERMIT #: 16016-20000-17734"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25765	19041-20000-32291	8410 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25766	19041-20000-51023	14833 W MORRISON ST	91403	4	169-5A149  15	2263029069	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.16043	-118.45634	Plan check for PV roof mounted system, PV system size: 9.20KW with 23 AC Modules, 1 sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25767	16041-20000-19566	13710 W FOOTHILL BLVD #1 - #42	91342	7	222B153   920	2509014095	(T)(Q)C2-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			06/03/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	03/20/2023 12:00:00 AM	ADDRESS	34.30854	-118.43227	PLANCHECK FOR POWER AND ENERGY. NEW 42 UNIT APARTMENT.  FIRE ALARM VARIANCE HAS BEEN SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25768	13041-20000-25221	5750 W WILSHIRE BLVD STE 640	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.06227	-118.3542	Plan check for energy and emergency lighting. Relocation of a few luminaires. Commercial high rise. 6th Floor. Suite 640.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25769	13041-10000-05185	639 N NORTH BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.05972	-118.2398	T24 FOR CHANGE OF USE FROM RETAIL TO STARBUCKS. 1658 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25770	15041-20001-07002	6550 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	34.18956	-118.60562	[[5/26/15  CHANGES TO APPROVED SET OF PLANS. PLANCHECK ONLY. DIMMING IS REMOVED ALL AREAS OF THIS SCOPE.  ALL AREAS ARE CONTROLLED BY EXISTING ENERGY MANAGEMENT SYSTEM. ]]]]PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NEW ACCESSORIES DEPARTMENT IN NEIMAN MARCUS TOPANGA PLAZA. 1374 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25771	15041-10000-06990	1965 N MOUNT OLYMPUS DR	90046	4	151-5A175 297	5569035007	RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.1075	-118.36601	PV1.  Install 15.696 kW roof-mounted, utility-interactive PV system.PERMIT FEE IS  0$ INCOMPLIANCE WITH SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25772	14041-20002-25275	12318 N EL ORO WAY	91344	12	219B133   577	2608022021	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.41	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.29446	-118.50438	CHANGE IN ROOF LAYOUT. NO CHANGE IN ELECTRICAL. RESTAMP NEW SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25773	14041-10000-14875	12666 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.97729	-118.41458	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25774	13041-20000-20008	4520 N CALLADA PL	91356	3	168B121   465	2177011006	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.15414	-118.54246	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9KW USING 39 MODULES. USING 2 CENTRAL TRANSFORMERLESS INVERTER. 4 TOTAL STRINGS. PLEASE CALL APPLICANT, APPLICANT WILL EMAIL DATA SHEETS WHEN PLANS GET ASSIGNED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25775	14041-20001-18593	14619 W VENTURA BLVD	91403	4	166-5A151  78	2265005007	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.15157	-118.45156	THIS APPLICATION IS FOR PLAN CHECK ONLY. THIS IS PLAN CHECK FOR T24 ENERGY COMPLIANCE. ORIGINAL APPLICATION CONTAINS PERMIT FEES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25776	13041-20000-28889	776 N VINE ST 1st floor	90038	13	141B189   142	5534034011	[Q]C2-2D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.08507	-118.32644	T.I. to an existing restaurant.  Occupancy load is less than 99, load is less than 400 amps.  Plan Check Only for ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25777	19041-20001-49880	4224 N SALTILLO ST	91364	3	165A107   265	2172023054	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			Reviewed by Supervisor	12/12/2019 12:00:00 AM	ADDRESS	34.14632	-118.59346	Expedited plan check fee.  PV1.  Install 8.65 kW DC roof mounted grid tied PV system.  (148) PV shingles with 3.8 and 5.2 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25778	16041-20000-16023	8422 N MCNULTY AVE	91306	3	192B109   454	2780004071	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.2228	-118.58704	PV1INSTALL ROOF MOUNTED PV SYSTEM 6KW INTERCONNECTED WITH MSP.(8) KYOCERA MODULES(2) 3.0KW INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25779	13041-10000-23190	107 N BOYLE AVE #105, #107	90033	14	129A221   178	5174024041	R3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	ADDRESS	34.04758	-118.2201	PLAN CHECK FOR TITLE-24 ONLY; TENANT IMPROVEMENT FOR TWO OFFICES (105 & 107). STANDALONE 400A SERVICE FEEDS TWO SUBPANELS, EACH AT 200A, PANEL A & PANEL B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25780	17041-10001-45890	2100 W 3RD ST Suite 220	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Info Complete	04/16/2018 12:00:00 AM	ADDRESS	34.06281	-118.2731	PC for revisions to dental office space. Changes in lighting and receptacles due to addition of soil utility room and W/H room. Changes clouded under delta 12.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25781	19041-10000-42632	21001 W KITTRIDGE ST	91303	3	180B109   222	2148029035	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	10/28/2020 12:00:00 AM		Permit Finaled	07/01/2023 12:00:00 AM	ADDRESS	34.19128	-118.5908	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW APARTMENT COMPLEX LOWRISE WITH  A THREE NEW 2000A SERVICE (120/208 3P,4W) THAT FEEDS THREE RESEDINTIAL DISTRIBUTION BOARDS, THESE DISTRIBTION BOARDS FEED ALL THE DWELLING UNIT PANELS. TOTAL AFFECTED T24 AREA IS 79,000 SQFT. NOTE, THESE PLANS INDICATE A PARKING STRUCTURE THAT IS ALREADY IN PLAN CHECK UNDER 19041-10000-37122.  B#19010-10000-04582 Per building__(FIVE STORY)  WITH 275 DWELLING UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25782	14041-10000-20782	7618 N WOODMAN AVE #8	91402	6	186B157   166	2214025025	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	PIN	34.208661	-118.4296486	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25783	19041-20000-51707	640 N HOBART BLVD	90004	10, 13	141B193   695	5521005006	C4-2, R3-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10, 2118.02	Electrical	Electrical	Apartment			12/16/2019 12:00:00 AM			Reviewed by Supervisor	01/23/2020 12:00:00 AM	ADDRESS	34.08287	-118.30564	Plan check for power and energy for 800A Service. Total area: 15,521 sq ft. Verify Building applicantion. Building work description: ***************************16 units apartment building 5 story.****************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25784	17041-10001-18633	6000 S WEST BLVD	90043	8	105B185   425	4006006001	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	33.98513	-118.33503	07-28-2017 Changes to an approved set of plan. Changes include remove daylit sensors in daycare area, office and kitchen. Changes apply to delta C and D only. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25785	12041-10000-17871	4170 S DEL REY AVE	90292	11	105B153    13	4230005033	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	33.98745	-118.44398	EV2 - PLAN CHECK POWER. NEW ELECTRICAL VEHICLE CHARGING STATION, 100KVA TRANSFORMER, AND 600A PANEL FOR EXISTING FEDEX BUILDING. BUILDING LOCATED IN METHANE BUFFER ZONE.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
25786	11041-10001-20021	10306 S WILMINGTON AVE # 101	90002	15	091-5A215 181	6066001045	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Info Complete	08/22/2013 12:00:00 AM	ADDRESS	33.94295	-118.23879	changes to approved set. plan check per inspector's request. see contact for contact informationlaundrymat new tenant. suite C	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25787	19041-20000-13132	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2342.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Issued	05/30/2019 12:00:00 AM	ADDRESS	34.02198	-118.33376	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from warehouse to office and parking garage and the addition of a 2nd floor. Work includes a new 1,200-amp service and a total lighting area of 42,690 sq. ft.Note: Building permit has been issued under 18014-10000-04633	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25788	17041-20000-45051	1670 W BEVERLY BLVD	90026	13	135A207   236	5153012023	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.06416	-118.26523	1000A 208Y/120V service upgrade for core and shell remodeled structure.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25789	16041-10001-04254	9204 S AIRPORT BLVD	90045	11	093B169    88	4125022017	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	33.95224	-118.38566	Full plan check. Changes to approved set of plans per inspector request. Adding new carwash equipment, additional circuits, new title 24 changes from original (additional light fixures)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25790	11041-20000-11911	6600 N TOPANGA CANYON BLVD FC 4	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK T24 ENERGY LIGHTNG/EMERGENCY FOR TENANT IMPROVEMENT RESTAURANT FC4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25791	10041-10000-22039	2723 W 8TH ST	90005	10	132A201    11	5077020802	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.02, 2122.04	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	34.05787	-118.28484	First time tenant for an office building. Plan check is for Power and T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25792	19041-10000-44505	3224 N BROADWAY	90031	1	138A225    54	5208010004	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	PIN	34.07342148	-118.20686292	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25793	15041-20000-19447	13924 W NURMI ST	91342	7	228B153   424	2503005023	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.32032	-118.43698	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. USING 16 MODULES. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25794	18041-10000-31202	1736 S NEW HAMPSHIRE AVE	90006	1	126B197   505	5075017007	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.04156	-118.29227	Install new fire alarm system, (1) FACP, (11) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25795	15041-10001-23419	906 W MIRAFLORES AVE	90731	15	021B197   485	7447001020	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	33.75296	-118.29702	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.79KW. 2 INVERTERS AND 25 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25796	16041-10000-03590	3084 S MOTOR AVE	90064	5	123B161   498	4316007009	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.03423	-118.41021	FULL PC FOR POWER AND ENERGY TO AN EXISTING COMMERICAL BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES FOR A COUNTRY CLUB. TOTAL AFFECTED AREA IS 30575 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25797	14041-20000-12032	12642 W SANDHILL LANE Unit #3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97765	-118.41437	Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 3 of 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25798	17041-10000-32060	2028 E 7TH ST	90021	14	124-5A217 263	5166015002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.03441	-118.23125	PC for T24 only for restuarant TI. Total area of 1790sqft. Installing new lights, receptacles, new panel, equipment. Load under 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25799	17041-30001-01596	10635 W SANTA MONICA BLVD 300, 305	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.05353	-118.43031	02/02/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the lighting controls and controlled receptacles.*****Previous Work Description*****PC for energy only for office space for 2093 sqft. Adding new  lights exceeding 10% of installed lighting for enclosed office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25800	17041-20000-34408	4960 N SEPULVEDA BLVD	91403	4	168B145    85	2263017005	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/26/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.16069	-118.46592	Plan check for power and energy. (N) 24-unit, 4-story apartment building with ground level parking. 1,000A 120/208V 3ph 4w service. 4 typical units. T24 area - 25,925sqft.Building permit application #16010-10000-01857.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25801	15041-10000-43343	403 E 5TH ST	90013	14	127-5A213 116	5148011014	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.04466	-118.24477	Full PC. Major renovation of an existing 4 story apartment. The number of units will be reduced from 219 to 72. Existing 1600 A service. 9 Typical units. All new load. Total Sqft = 17034.Fire variance on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25802	17041-10002-14243	1414 N CATALINA ST	90027	13	147B197   848	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/19/2018 12:00:00 AM	ADDRESS	34.09716	-118.29486	PLANCHECK ONLY. CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATION OF EXISTING LIGHTING SYSTEM, LOAD CALCULATIONS, EQUIPMENT LOCATON AND SPECIFICATION. ALL CHANGES NOTED UNDER DELTA 1, 2 & 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25803	15041-10000-02073	9200 N OAKDALE AVE 6th floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for office TI.  No lighting alterations per applicant - plan check only covers the controlled receptacle requirement of Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25804	13041-10000-13796	3650 W MARTIN LUTHER KING, JR BLVD SUITE 109	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING IN AN EXISTING TENANT SPACE AT THE BALDWIN HILLS MALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25805	12041-20001-07209	3584 S FIGUEROA ST Suite 3	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM			PC Approved	08/08/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	Modifications to previously approved lighting system, some luminaires and quantity of luminaires changed as shown by the Delta 5 modifications.  No change in the electrical system.  Permit issued on application number 12041-10000-07209.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25806	14041-20000-35555	8905 N GLENOAKS BLVD B-A	91352	6	195B173   278	2408008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.23033	-118.36723	Plan check for power and energy. First time tenant. New restaurant. Due to building submittal plan check for 2008 building efficiency standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25807	16041-20001-20001	110 E 9TH ST 12TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Closed	02/09/2024 12:00:00 AM	ADDRESS	34.04107	-118.25479	changes to an approved set of plans. adding new condensing unit and fan coil.  new circuits in server room 168. changes noted delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25808	16041-10001-44035	10250 W SANTA MONICA BLVD # 1997	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	08/01/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"[Plan check only, permit is covered under master plan]  1st revision to approved set on ""Uno de 50"" Ste. 1997.  replace lighting fixtures, remove entry area lighting fixtures, update T24 calculation, update load calculation per new lighting plan. Changes noted under delta 6,7,8,9"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25809	14041-20001-30144	1136 W 6TH ST	90017	1	132A207   615	5143024015	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM			PC Approved	02/10/2016 12:00:00 AM	ADDRESS	34.05447	-118.26366	Change to approved set of plans. Changes include  to 14/2 shielded FPLR manufactuer fire phone jack riser cable. Changes apply to delta 1 only{{{{{{INSULATION OF A NEW FIRE ALARM SYSTEM. 8 STORY BUILDING. 1 FACP, 2 RPS, 301 DEVICES}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25810	12041-10005-27734	2500 S NAVY WAY MARINEOPS	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			11/16/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.73363	-118.2408	Modify existing fire alarm system for Pola Maersk (port of LA) 6of 6 Marine Operation Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25811	15041-20000-39136	20438 W ACRE ST	91306	3	195B109   183	2781006019	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM			Reviewed by Supervisor	12/01/2015 12:00:00 AM	ADDRESS	34.22978	-118.57884	PV1. AN ADDITION TO AN EXISTING SOLAR SYSTEM ON AN EXISTING RESIDENTIAL ROOF-TOP. NEW ADDITION IS 3.0KWac.  TOTAL SYSTEM SIZE IS 7.0KWac. (8) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25812	14041-20000-09532	21919 W ERWIN ST	91367	3	177B101    65	2146029003	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.18306	-118.60499	pc for temp power. 800A service for contruction. pc for service section only. no loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25813	18041-10000-33235	4201 W WILSHIRE BLVD 6TH FLOOR	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.06189	-118.31911	PLAN CHECK FOR POWER AND ENERGY FOR ON 6TH FLOOR OF HIGHRISE BUILDING  - TENANT IMPROVEMENT TO EXISTING OFFICE SPACE ON 6TH FLOOR (34945SF): NEW NON-STRUCTURAL PARTITION WALLS, (N) CEILING - TOTAL NEW CONNECTED LOAD >400A, TOTAL AFFECTED AREA = 33710 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25814	15041-20000-31842	17301 W QUESAN PL	91316	5	165B133   187	2292017005	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.15024	-118.5094	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 21.05 KW(61) SUNPOWER SPR 345 MODULES(1)  SOLAREDGE SE11400A INVERTER(1) SOLAREDGE SE5000A(61) SOLAREDGE DC-DC OPTOMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25815	18041-10000-18477	8966 N COMANCHE AVE	91311	12	195B113    11	2781035047	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.23418	-118.57215	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25816	10041-10001-23431	11715 W GOSHEN AVE	90049		129B145   485	4265010005	R3-1		Brentwood - Pacific Palisades				Electrical	Electrical	Apartment			07/20/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.05008	-118.46232	NEW 9- UNITS APARTMENT BLDG.  MODIFICATION TO PREVIOUSLY APPROVED SET, PLAN CHECK IS FOR ENERGY AND POWER.  PLEASE RETURN APPROVED SET TO APPLICANT WITH CORRECTIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25817	14041-10000-19395	11750 S JEFFERSON BLVD	90230	11	105B165   218	4220015033	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	PIN	33.98626775	-118.40053173	NEW FA FOR ONE STORY COMMMERCIAL BUILDING. ONE MAIN PANEL, ONE ANNONCIATOR PANEL, 16 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25818	17041-20000-36964	245 S CONWAY AVE	90024	5	138B153    31	4359008015	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.07821	-118.43476	PV1.  Plan check for a 9.96 kW AC roof-mounted PV system.  (30) modules, (30) micro-inverters, and (2) load centers. PV system is interconnecting with a 600-amp service.$15.31 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25819	16041-30000-26342	10400 S AVIATION BLVD	90045	11	090B173   318	4129034001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	33.94154	-118.37829	PLAN CHECK FOR POWER HAZARDOUS LOCATION CLASS 1 DIV1.SOUTHERN CALIFORNIA GAS INSTALLING NEW UTILITY PEDESTAL AND AUTOMATION CONTROLLERS FOR SAFETY VALVE ACTUATORS.B#: 16020-30000-03362	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25820	13041-10000-07110	526 S MAIN ST	90013	14	129A211   236	5148019007	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Expired	04/15/2015 12:00:00 AM	ADDRESS	34.04594	-118.24901	CHANGE OUT EXISTING PANELS AND FIRE ALARM DEVICES. EXISTING SYSTEM TO REMAIL. NEW PANEL AND A COUPLE NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25821	18041-20000-17438	19201 W VENTURA BLVD	91356	3	174B117   686	2163019013	C2-1VLD, RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Issued	05/10/2018 12:00:00 AM	ADDRESS	34.17277	-118.55148	Plan check for Title 24 only in existing space T.I. Total area: 517 sq ft.B#18016-20000-13337	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25822	15041-10000-24070	1500 W PACIFIC COAST HWY Bldg J	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 15 unit apartment with garage, 43 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25823	13041-20000-14441	1837 S FAIRFAX AVE	90035	10	126B173   542	5066017020	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	PIN	34.04204935	-118.37000269	pv1 single family dwelling. total system size 4.3kw. using 20 modules. enphase m215 microinverter standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25824	19041-10000-23790	4616 S BROADWAY	90037	9	112-5A203 342	5110008029	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.00147	-118.27811	NEW FIRE ALARM SYSTEM IN AN OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25825	09041-10001-02895	971 N YALE ST	90012	1	136-5A215 239	5414003012	C2-2D-O	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM			Reviewed by Supervisor	08/25/2010 12:00:00 AM	ADDRESS	34.06681	-118.23916	Delta 5 modifications only to the  previously approved set of plans for a NEW 3-STORY TYPE BLDG TO HOUSE SENIOR CITIZEN/NURSERY ACTIVITIES FOR SUNDAY SCHOOL (PRIMARILY) ASSESORY TO (E) WORSHIP CENTER. Installing New panel board, distribution board and circuits. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25826	17041-20000-42256	21113 W SHERMAN WAY	91303	3	183B105    74	2112022024	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.20121	-118.59343	ti to an existing commercial space. adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25827	16041-10000-12232	1328 W 220TH ST	90501	15	048B193   296	7346014018	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Expired	05/25/2018 12:00:00 AM	ADDRESS	33.82789	-118.3005	PV1, INSTALL A NEW 5000 W AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: CANADIAN SOLAR CS6X-315(1) INVERTER: GROWATT US/5000MTL 5200 W	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25828	15041-20000-19283	7607 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.20878	-118.46495	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25829	17041-20000-40465	16241 W SCHOENBORN ST	91343	12	192B137   243	2689005010	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.22245	-118.48698	PV1.  Install 11.895 kW DC roof mounted grid tied PV system.  (39) modules with 11 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25830	13041-10000-07497	1701 E CESAR E CHAVEZ AVE SUITE 545	90033	14	130-5A221 204	5174007047	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.05126	-118.2173	TI FOR A MEDICAL SUITE IN A 5-STORY BUILDING.  WORK BEING DONE ON 5TH FLOOR, SUITE 545.  FULL POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25831	13041-10000-34339	910 E 61ST ST	90001	9	105B209   123	6007008003	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Expired	03/26/2015 12:00:00 AM	ADDRESS	33.98432	-118.25922	"permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. ectrical, HVAC and Plumbing) with a work description as follows. ""COMPLY WITH DEPARTMENT ORDER effective date 06/09/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25832	16041-10000-28703	948 W 81ST ST	90044	8	099B197  1055	6032005011	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Expired	09/25/2018 12:00:00 AM	ADDRESS	33.96534	-118.29071	Plan check for PV residential roof mounted system. Total system size: 2.58kWac with 12 microinverters and 12 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25833	13041-10000-12614	9040 W PICO BLVD	90035	5	132B169   879	4305007029	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.05505	-118.38885	pc for power and energy. CHANGE OF USE FROM EXISTING ONE STORY FURNITURE BUILDING TO AN ORTHODOX SYNAGOGUE INCLUDING PARTIAL DEMO  15215 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25834	19041-10000-23321	21050 W CALIFA ST	91367	3	174B105    11	2149002020	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.1771	-118.59179	NEW PANELBOARD, CIRCUITS, AND LIGHTING IN AN EXISTING STUDIOPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25835	13041-20000-34854	13479 N GLENOAKS BLVD	91342	7	225B145    57	2501020012	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Info Complete	05/02/2014 12:00:00 AM	ADDRESS	34.31709	-118.46235	New 7,946 sq ft retail building.  New service, lighting, full plan check.  Building is feed from a separate building to a 300kva transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25836	19041-10000-24318	1050 S GRAND AVE SUITE 1	90015	14	127-5A207 345	5139010***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Issued	07/02/2019 12:00:00 AM	ADDRESS	34.04171	-118.26155	FULL PLAN CHECK FOR FIRST TIME TENANT (REALTY OFFICE) IN A HIGH RISE. SCOPE INCLUDES NEW 15KVA TRANSFORMER SERVED FROM A 100A PANEL CONNECTED TO THE 400A COMERCIAL SERVICE DISTRIBUTION BOARD. THIS TENANT IS THE FIRST OF 3 TENANTS. TOTAL AFFECTED AREA IS 974 SQ.FT B#19016-10000-11428	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25837	13041-10000-20680	19900 W MAYALL ST	91311	12	204B113   509	2726002025	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.25352	-118.56706	PV1 8.82KWdc 240V XFMR INV. 1STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 36) MOD: TRINA {TSM-245PC05.18}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25838	17041-10000-15008	968 N FORMOSA AVE	90046	5	144B181   617	5531016003	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.0887	-118.3461	Plan check for power and Title 24.  New 8 story parking structure with (24) future EV charger spaces.  New 800 amp service.  Total area = 140,357 sq. ft.     Building permit #17010-10000-01356	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25839	17041-20001-45768	13526 W CREWE ST	91405	2	183B157   649	2328011042	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	PIN	34.19641256	-118.42777302	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (45) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25840	19041-20000-21989	1638 S NORTON AVE	90019	10	126B189   415	5072011021	RD2-1-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.04269	-118.32574	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM CONSISTING OF A 13.5 KWH TESLA POWERWALL AND A NEW 125A PANEL TO EXISTING SFD WITH EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25841	17041-10000-06703	100 W 87TH PL	90003	8	096A203   147	6040021021	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.95782	-118.27432	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR) TOTAL AREA 2100 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25842	12041-10000-23956	3680 S KEYSTONE AVE	90034	11	120B161  1178	4314009020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.02	Electrical	Electrical	Apartment			10/09/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.02189	-118.4079	New fire alarm system for 12 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25843	16041-10007-24464	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Closed	05/01/2019 12:00:00 AM	ADDRESS	34.09818	-118.35187	"Changes to an approved set of plans. All changes are clouded under delta 18.7 under bulletin 18. Changes include relocating/replacing lighting fixtures, updated lighting floor plans, revising title 24 calculations, revising emergency photometrics, revising panel schedules, and adding/removing circuits on panel schedules. Updating panel schedules ""P4"" for added signage circuits, adding lighting circuit on panel ""L1"", and removing circuit on panel ""P5""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25844	12041-10000-01550	3450 S WATT WAY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.02275	-118.28604	Change of lighting and new circuits for HVAC and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  No suite number, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25845	17041-20003-03636	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022058	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			PC Approved	09/21/2018 12:00:00 AM	ADDRESS	34.21384	-118.44905	09/21/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta H. Emergency egress lighting power source has changed to battery packs. Inverter has been removed. All lighting changes have been reflected onto the floor plans and Title 24 forms.4/26/2018Revisions to approved set.  Changes noted delta G.  Revision of feeder schedule and associated feeder voltage drop and fault current calculations.  2/27/2018changes to an approved set of plans. changes noted delta D E F.  changes include revision of equipment/floor lay-out and circuits.  no additional load.  this is plan check only.    New 6-story commerical building gymnasium and parking (3 levels fitness center with 3 levels parking).  Underground 3000A 208V 3ph-4w service.  176,784 sq ft.  Plan check for power and energy.  Electrical permit has been issued under 15041-10000-28641 under previous design (same engineer).  Full resubmittal due to extensive scope of work changes - from 2000A to 3000A service, complete system redesign.)))Building permit under 13010-10000-04552.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25846	17041-20000-22379	2040 S MANNING AVE	90025	5	129B157   756	4321006025	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	09/02/2017 12:00:00 AM	ADDRESS	34.04892	-118.42783	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25847	18041-10000-05172	879 W 190TH ST # 410	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	06/16/2018 12:00:00 AM	ADDRESS	33.85951	-118.28963	TENANT IMPROVEMENT AT SUITE # 410 OF ( E ) OFFICE BUILDING : NEW PANELBOARD . LIGHTING, AND CIRCUITSPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25848	18041-10000-21244	10250 W SANTA MONICA BLVD #2010	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PLAN CHECK FOR  AN EXISTING  RESTAURANT T.I "" SUGAR FACTORY """	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25849	14041-20006-29874	12860 W RIVERSIDE DR	91423	4	168B161   422	2357033021	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	PIN	34.15733931	-118.41348969	New car wash structure and accessible restroom to (E) gas station.  Service upgrade to 1200A 208Y/120V.  New site lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25850	17041-10000-25313	5508 S DUARTE ST	90058	9	108B213   295	5105012028	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	33.99256	-118.24209	Plan check for Service upgrade to 800A  120/240V 3 Phase, 4 W Exterior U/G Service. All existing loads re-fed, no new lighting or other loads on this project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25851	14041-20000-00278	23516 W HATTERAS ST	91367	3	174B093   128	2041009008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2014 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Expired	02/01/2016 12:00:00 AM	ADDRESS	34.17539	-118.63894	PV1 STANDARD PLAN. TOTAL SYSTEM SIZE 7.5KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25852	18041-10000-09101	316 W 2ND ST	90012	14	130-5A211  19	5149009024	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Info Complete	03/21/2018 12:00:00 AM	ADDRESS	34.05265	-118.24741	PC for T24 only for new lighting for penthous/ office space. Installing new lights and receptacles. Total area 2215sqft. B# 18016-10000-07276.PERMIT WAS ISSUED UNDER 18041-90000-20048	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25853	10041-10001-01589	6282 W HOLLYWOOD BLVD	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM			PC Approved	07/07/2010 12:00:00 AM	ADDRESS	34.1014	-118.32618	Change the priviously approved plan. Addition of  Mezzanine and change the lights.  Plan check for the change. ((((((((((Change of use from retail to restaurant.  T-24 and emergency lighting.))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25854	18041-10000-27203	1251 S LA BREA AVE	90019	10	129B181   282	5084028050	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.05199	-118.34443	PLAN CHECK FOR T24 ONLY, TI REPAIR THE FIRE DAMAGED WALLS FOR THE EXISTING AND APPROVED MASSAGE PARLOR. TOTAL AREA: 1,275 SQ.FTB# 18016-10000-18905	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25855	18041-10000-15971	1816 S OAK ST	90015	1	124-5A203  22	5124017002	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.03774	-118.27684	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25856	15041-10000-25738	624 S GRAND AVE	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	PIN	34.04778206	-118.25563275	REMOVAL OF EXISTING GENSET FLS AND RECONNECTING (2) FLS CIRCUITS. PLAN CHECK FOR POWER ONLY.(VARIANCE FOR REMOVAL AND RECONNECTING OF FLS CIRCUITS TO ANOTHER GEN ON FILE.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25857	19041-10000-44411	6380 W WILSHIRE BLVD 1400	90048	5	135B173   874	5088014021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.06348	-118.36826	T-24 PLAN CHECK FOR A TI TO EXISTING SPACE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. NEW CONNECTED LOAD IS LESS THAN 400A. TOTAL AFFECTED AREA IS 7270 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25858	10041-10001-00553	6040 W SUNSET BLVD 5th Floor	90028		147A189    54	5545013402	M1-1		Hollywood	Hollywood Studio District			Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM			PC Approved	05/13/2010 12:00:00 AM	ADDRESS	34.0978	-118.32068	Revisions of permitted set of plans :  in the pantry relocated luminaires in order to make revisions to nearby DDCbay room; moved walls to expand the areas of enclosed office. all changes are bubbled.on the plans .  Core and shell under #06041-10000-02712	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25859	15041-20000-03533	12777 W JEFFERSON BLVD 1ST FLOOR	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.9778	-118.41768	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR OFFICES. TWO STORY BUILDING.  FIRST FLOOR ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25860	18041-10000-02476	4201 W WILSHIRE BLVD 5TH FLR.	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.06189	-118.31911	PC for T24 only for new lighting in restrooms. B# 17016-10000-35292. Total area is 1015sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25861	12041-10000-24583	1328 N DEVLIN DR	90069	5	144B169    82	5560036011	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.09439	-118.38573	PV1 - PLAN CHECK 10.56KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM (TWO INVERTERS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25862	19041-20000-16208	5632 N WILLOW CREST AVE	91601	2	174B177   450	2415023028	RD1.5-1VL	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	Apartment			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	10/20/2020 12:00:00 AM	ADDRESS	34.17307	-118.36251	Plan check for a fire alarm system for a 3-story, 4-unit apartment building. Fire alarm consists of (1) FACP and (25) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25863	14041-10000-22801	7558 N RESEDA BLVD	91335	3	186B125   264	2119017029	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.20792	-118.53585	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.For autoshop (NON-HAZARDOUS PER APPLICANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25864	15041-20001-39253	8312 W 3RD ST	90048	5	138B173   896	5511031037	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.07258	-118.37052	02/05/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms. *****Previous Work Description*****Plan check for Title 24 only restaurant in existing space. Total area: 1,000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25865	19041-10000-03893	718 S ALVARADO ST	90057	1	132A203   155	5141019003	C2-2	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Apartment			01/31/2019 12:00:00 AM			PC Approved	12/31/2019 12:00:00 AM	ADDRESS	34.05586	-118.27701	SERVICE UPGRADE TO 600 AMP IN AN EXISTING APT BUILDING.NO NEW LOAD ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25866	13041-10000-00247	1751 N LAS PALMAS AVE	90028	13	150A185   354	5547002030	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			01/04/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.10334	-118.3364	T24 AND POWER FOR NEW 5 STORY APARTMENT BUILDING.  24 UNITS TOTAL.fire alarm plans approved under permit #130411000015410	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25867	11041-10002-08441	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM			Corrections Issued	10/23/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	Change to approved set.  Change of feeder from 10' tap rule to 25' tap rule, per inspector's request.  <<<<TEMPORARY POWER FOR CONSTRUCTION AT BRADLEY TERMINAL WEST CONCOURSE.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25868	11041-10000-08484	515 S FIGUEROA ST 19th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			Plans on Hold	10/18/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	"Ti in an existing office area on the 19th floor in Office of ""Hirschmann Law"". EPC is for T24."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25869	10041-20000-00211	13606 W VICTORY BLVD	91401	2	180B157   959	2330012022	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM			PC Approved	01/06/2010 12:00:00 AM	ADDRESS	34.1865	-118.42958	Tony's Coffee ShopEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25870	18041-20002-17751	11805 W GWYNNE LANE	90077	5	153B141   103	4378037075	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	34.11583	-118.47417	01/16/2019 Changes to an approved set of plans. Electrical equipment has been relocated.11-01-2018 Changes to an apporved set of plan. Changes include addition on 2 Tesla Power Wall 2.0. Energy Storage Device system size: 27kWh.  All changes has been clouded.*****Original Work Description*****PV1.  Install 9.425 kW DC roof mounted grid tied PV system.  (29) modules with (2) 5.2 kW rated string inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25871	14041-20000-30115	13429 W CANTARA ST	91402	6	192B157   749	2301002015	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.21994	-118.42563	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZED 6.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25872	14041-20000-27258	8827 N OAK PARK AVE	91325	12	195B133   268	2690012009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.23112	-118.50561	install roof mounted pv system sized 7.6kw interconnected to msp.(30) solar world modules(30) power optimizers(1) solar edge 7600 inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25873	13041-10000-08744	9717 W PICO BLVD	90035	5	132A165   258	4330018024	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.05485	-118.40008	fire alarm system fire commercial building.  PERMIT IS FOR PANEL ONLY. FIRE ALARM DEVICES ALREADY PULLED BY EXPRESS PERMIT. ORIGINAL PERMIT FOR DEVICES UNDER APPLICATION # 13041-10000-06433.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25874	14041-20001-15285	6355 E CHURCH ST	90042	14	157-5A233 202	5483006007	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.12494	-118.17735	Plan check only for relocating the inverter and junction box.(((PV1.  Install 4 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with DC converters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25875	18041-10000-07045	11151 N LAUREL CANYON BLVD	91340	7	210B149   482	2613025054	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.27257	-118.44709	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 166000 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25876	19041-10000-02786	24511 S FRAMPTON AVE	90710	15	123B181  1167	5049004019	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Harbor City		2197.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.8022	-118.29931	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25877	14041-20000-05411	7422 N DEMPSEY AVE	91406	6	186B141   437	2206027008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Expired	03/28/2016 12:00:00 AM	ADDRESS	34.20546	-118.47596	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC. USING SOLAR OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25878	14041-20001-08056	1660 E 23RD ST	90011	9	117A213   113	5118021009	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.01588	-118.24434	"Plan check for Title 24 for installation of (3) lighting fixtures in transformer room per inspector request.  Shell building as per applicant.  (((PLANCHECK FOR POWER.  REPLACE DAMAGED/VANDELIZED EXISTING 1200 AMP 3PHASE 4 WIRE SWITCHGEAR WITH NEW 800AMP 3 PHASE 4WIRE. ""ALL WORK TO BE INDOORS "" )))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25879	19041-20000-27665	4842 N TILDEN AVE	91423	4	169-5A151 134	2248005004	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.15887	-118.44747	Plan check for PV roof mounted system, PV system size: 13.1KW AC, 15.1KW DC with 41 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25880	14041-20000-17593	8530 N BROWNS CREEK LANE	91304	3	192B105   718	2779010199	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.2256	-118.59174	PV1.  Install 4.578 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25881	16041-10000-09237	777 S FIGUEROA ST SUITE 3000	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	03/16/2016 12:00:00 AM	ADDRESS	34.04828	-118.26116	ALTERATIONS IN OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25882	11041-20000-02606	10819 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.26665	-118.52367	PLAN CHECK T24 ENERGY AND EMERGENCY LIGHTING. TENANT IMPROVEMENT FOR A RETAIL BUILDING CONVERSION TO A PETCO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25883	18041-20001-42553	10550 N NORTHRIDGE HILL DR	91311	12	207B117   377	2708014005	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.2619	-118.56245	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size 21.45 kWdc/19.375 kWac and consists of (3) inverters, (65) modules, (1) back-up battery, and (2) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25884	18041-10001-09308	2515 W BEVERLY BLVD	90057	13	136-5A203 121	5157009027	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.06907	-118.27536	PLAN CHECK FOR LOST SET OF PLANS FULL PLAN CHECK, CHANGE OF USE FROM OFFICE TO CHARTER SCHOOL; NEW 800A SERVICE, (12) PANELBOARDS, TOTAL AREA 30,825 SQ.FT (INDOOR+OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25885	19041-20000-27249	14072 N CARLTON LANE	91342	7	231B153   145	2582041***	(T)(Q)RD6-1, QRD6-1	North Valley	Sylmar	Sylmar	YES	1060.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.32824	-118.44014	Plan check for PV roof mounted system installed into existing PV system, New system size: 5.28kW DC, 4.488KW AC with 16 PV Modules and 1 inverter(5.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25886	10041-10000-07881	611 W 7TH ST	90017	9	129A209   115	5144006023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04768	-118.25692	+REMODEL THE BAR AREA INSDE A RESTAURANTPLAN CHKIS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25887	19041-20000-37164	7885 S NAYLOR AVE	90045	11	099B165   536	4106019004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	33.96753	-118.39531	PV1. INSTALL 3.60 KW DC SOLAR SYSTEM WITH (9) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25888	19041-10000-06939	3931 S LYCEUM AVE	90066	11	111B153  1286	4236023013	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			Reviewed by Supervisor	03/04/2019 12:00:00 AM	ADDRESS	33.99621	-118.4399	PC for ROOF MOUNTED PV ON SFD.System includes (21) modules (REC solarr: RETP2), (21) 320 solar edge optimizers, (1) LG chem 5kw battery, (1) solar edge 7600 inverter. (1) load panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25889	17041-10000-44988	6423 N HESPERIA AVE	91335	3	180B125   614	2123015002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.18746	-118.52631	PC FOR UPGRADES PV SYSTEM SCOPE INCLUDES ADDITION OF 19 MODULES (4.56KW AC) TO EXISTING 24 MODULES FOR A TOTAL SYSTEM SIZE OF 10.32KW(AC) MICROINVERTER SYSTEM WITH LOAD CENTER. INSPECTOR REQUESTED FOR A SINGLE PERMIT FOR TOTAL NUMBER OF MODULES (43) DUE TO NEW SYSTEM CONFIGURATION. EXISTING SYSTEM ON 15041-90000-23961 FOR A TOTAL SIZE OF 5.76kW.Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25890	17041-20001-00188	10400 N CAYUGA AVE	91331	7	204B157    90	2620022006	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.25925	-118.42223	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.3.84kW ungrounded system. (16) EnPhase M250 microinverters. (16) 290W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25891	17041-20000-25100	15760 W VENTURA BLVD SUITE 820	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. HIGH RISE. 8TH FLOOR. SUITE 820. 1015 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25892	14041-20000-04616	22443 W HAYNES ST	91307	12	180B101   425	2038033017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Expired	04/19/2016 12:00:00 AM	ADDRESS	34.18981	-118.61625	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25893	10041-20001-00465	6600 N TOPANGA CANYON BLVD #2006	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM			PC Approved	05/03/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for revision to approved plans.  Revisions are clouded. Changing to step-up transformer. Request for Modification to separate Fire Alarm system filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25894	17041-20000-44785	5805 N SEPULVEDA BLVD Suite #400	91411	4	174B145   102	2243001009	M1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.17593	-118.46647	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES TO 4TH FLOOR. SUITE 400.  14836 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25895	16041-10003-16867	8420 N BALBOA BLVD WEST-BLDG	91344	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	*************    SEE APPLICATION COMMENTS  ********************PC FOR CHANGES TO APPROVED SET PER INSPECTION UNDER DELTA 9. (WEST BUILDING)SCOPE INCLUDES REDUCTION IN SCOPE TO REFLECT FIELD CONDITIONS AND INCLUDE: LIGHTING (INDOOR AND OUTDOOR), EQUIPMENT, LOADING AND T-24 REVISIONS. THIS IS PLAN CHECK ONLY.  one of two new buildings with retail tenant spaces-SHELL/CORE ONLYThis North Building (16010-10000--00456) plans will be reviewed under this application.A separate application will be required for plan review of the plans for the West Building (16010-10000-004550)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25896	16041-20000-22735	3624 N OAK HILL AVE	90032	14	144A231   248	5213010003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.08773	-118.18639	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25897	13041-20000-08070	2318 S CLOY AVE PV-1	90291	11	106-5A147  75	4228007018	R1-1	West Los Angeles	Venice	Venice		2739.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	33.98713	-118.45943	PV-1. MIcroinverter standard plan. 4.3kW AC Total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25898	19041-20001-34332	4750 W WILSHIRE BLVD 1ST FLR	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.06185	-118.3338	09-17-2019 Changes to an approved set of plan, Changes include update as built, reuse existing distribution as normal distribution and reconnect 4000A normal distribution existing 4000A Service. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25899	19041-20001-11934	817 N VINE ST	90038	13	141B185   248	5533030029	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	01/20/2022 12:00:00 AM	ADDRESS	34.0858	-118.32679	Revision to approved set.  Additional 75 kVA transformer and downstream distribution.  Revisions to architectural layer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25900	18041-10000-39709	1700 S SOTO ST	90023	14	118-5A221 147	5169017014	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.01824	-118.21987	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
25901	19041-20001-38245	10929 N COLLETT AVE	91344	12	210B141   913	2667007005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM			PC Approved	10/25/2019 12:00:00 AM	ADDRESS	34.26907	-118.48378	PLAN CHECK ONLY FOR NEW PV SYSTEM USING (28) AC MODULES. TOTAL SYSTEM SIZE IS 8.96 KWAC/9.16 KWDC. ____________________________________________________________Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25902	13041-20000-15501	12025 W WATERFRONT DR 4TH FLOOR	90094	11	105B165   915	4211011031	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	33.98265	-118.40487	T24 FOR OFFICE BUILDING #3 ON THE FOURTH FLOOR. 4665 SQRFT. FOLLOWING CHANGES WERE MADE ON THE PLANS: USING 20W DRIVER FOR LED STRIP LIGHT, 35W MR16, AND ENERGY EFFECIENT (4)32T8 AT 101W PER FIXTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25903	14041-20002-10232	655 S HOPE ST #101	90017	14	129A209   262	5144006901	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.04849	-118.25759	09/21/2015 Changes to an approved set of plans. Changes have been made to the lighting floor plan and the light fixture schedule. All changes have been clouded and reflected on the Title 24 Compliance Forms. Plan re-check for lost set of supplemental plans.*****Previous Work Description*****Remodel for new restaurant on ground floor of existing commercial highrise building.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25904	16041-20002-08073	453 S KENMORE AVE	90020	10	135B197   753	5502013018	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Apartment			08/08/2018 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	ADDRESS	34.06567	-118.29698	8/8/18changes to an approved set of plans.  changes to provide series rated combination to unit panels only, notes 8,9,10 only and increase size of inverter to 9KVA.this is plan check only.  ((((NEW FIVE STORY APARTMENT BUILDING, 69 UNITS, ON TOP OF TWO AND ONE HALF LEVEL ABOVE GRADE PARKING STRUCTURE. 3000 MSA, 13 Typical units. Total area: 61,992sq.ft (indoor) + 3,027 sq.ft (outdoor). Building is on METHANE ZONE and No work is done underground inside the building.**Fire Alarm variance is filed together with this application.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25905	11041-10001-24487	1016 E LAKE ST BLDG 6-1	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			10/03/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.00173	-118.46049	Lincoln Place Apartment Building Project.  New 2-story apt. building with 8 units.(((((((((((((((((((   10-3-14 M.Z   addition of 5  20 amps E.V.))))))))))))))))))))))))))))))))	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25906	16041-20000-36712	7511 W ALPINE WAY	91042	7	213B197    79	2552043019	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.27748	-118.29582	$0 permit fee per State Senate Bill SB 1222. Plan check for a PV1 roof-mounted PV system. System size is 13.5 kWac and consists of (54) modules, (54) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25907	19041-10001-12693	8018 W 3RD ST	90048	5	138B177   762	5511028027	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.07179	-118.36448	Plan check Only. DELTA 1 CHANGES TO AN APPROVED SET. CHANGES TO FLIGHTING FLOOR PLANS, POWER FLOOR PLANS AND T-24 CALCULATIONS. Change four F1 fixtures to F2 fixtures.Relocation EM lightRemove J-boxRemoving ceiling linear lights and install milwork strip lightsReplacing duplex outlet with quads. All changes are highlighted by the plancheck engineerOriginal scope: Energy plan check for a change of use from restaurant to a a retail. Scope includes new lighting and equipment with a total area of 776-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25908	13041-20000-33706	15506 W SYLVAN ST	91411	6	177B145   129	2242005027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.1849	-118.47149	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 1.7 KW AC USING ENPHASE MICROINVERTER USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25909	15041-20000-36731	3007 N LAKE GLEN DR	90210	4	159B161   426	4386003017	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.1282	-118.40932	Plan check for a PV1 ground-mounted PV system. System size is 15.4 kWac and consists of (2) inverters, (45) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25910	12041-10000-22436	1720 W 25TH ST	90018	8	123B193   502	5058029004	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Expired	11/13/2014 12:00:00 AM	ADDRESS	34.03354	-118.30087	NEW 4.578 KW ROOF MOUNTED PV FOR A SINGLE FAMILY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25911	15041-10000-31995	131 S AVENUE 61	90042	14	153A231   400	5492028902	PF-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.1116	-118.18702	pv2, install 2.6 kw dc roof-mounted solar array on a utility structure. main service PANEL is existing.(10) modules: CANADIAN SOLAR CS6P-260P(1) INVERTER: SMA SB2500 HFUS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25912	15041-20002-28493	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Info Complete	12/23/2015 12:00:00 AM	ADDRESS	34.24143	-118.56249	12/23/2015 Changes to an approved set of plans. Changes include revisions of power plan and the addition loads. All changes have been clouded and marked as Delta 1, 3, and 4.*****Previous Work Description*****Plan check for power and energy for T.I. work within existing space. Total indoor area: 4,536 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25913	17041-10000-46473	1851 S WOOSTER ST	90035	10	126B169   162	4303007028	R1R3-RG	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.04471	-118.3846	PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (200A), 2 BATTERIES RATED AT 11.6KWac WITH EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25914	14041-10001-11008	10861 W WEYBURN AVE Ralph's	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.06247	-118.44344	(  10-2-2014  M.Z   changes made to previusly approved set  which incloudes complete emergency lighting, changed from gen set to unit equipment. UPS addeted for data,  added new ckts------------------------)))))))))))))    PLAN CHECK FOR POWER AND ENERGY FOR EXPANSION OF EXISTING RALPHS STORE. STARBUCKS IS INCLUDED WITHIN THE SCOPE OF THIS WORK. FEES CALCULATED PER APPLICANT. TO BE VERIFIED DURING PLAN CHECK. STARBUCKS TO BE PART OF SCOPE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25915	13041-20000-32583	15963 W STRATHERN ST	91406	6	189B141    23	2206005021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.21581	-118.48145	New 1200 amp board, motors to be fed from two separate services with kirk-key.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25916	15041-10000-31367	210 S MAIN ST	90291	11	111B141   486	4286003021	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	33.99746	-118.47881	T-24, TI to an existing commercial building (office spaces). Existing service and equipment. New lighting and receptacles are being added to the site. PC for energy only. Sq Ft = 4396	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25917	17041-10001-43496	3458 E WHITTIER BLVD	90023	14	121-5A227 185	5188017002	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	08/12/2020 12:00:00 AM		Permit Finaled	12/31/2020 12:00:00 AM	ADDRESS	34.02687	-118.19926	Change to approved set by adding new service (1000-Amp), new ckts, and modifying the floor plan. (((FULL PLAN CHECK FOR POWER AND ENERGY. TI TO EXISTING MC DONALDS , ADD 1 NEW PANEL CONNECT TO EXISTING SERVICE.,  NEW LOADS > 200A. ((B# 17016-10000-35807)) )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25918	11041-10000-04031	1850 N WHITLEY AVE 5TH FLR	90028	13	150A187   270	5547005019	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			03/03/2011 12:00:00 AM			PC Approved	03/11/2011 12:00:00 AM	ADDRESS	34.10468	-118.3332	T.I.  REPLACING CORRIDOR LIGHTING FOR THE 5TH FLOOR OF A HIGH RISE (12 FLOORS) APARTMENT BUILDING.  TITLE 24 PLAN CHECK ONLY.  EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25919	16041-20000-21399	19500 W PLUMMER ST SUITE E	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.2426	-118.55846	"ADDING NEW 600 AMP DISTRIBUTION BOARD ""MDPC"" TO EXISTING BOARD MDP.  PLAN CHECK FOR POWER, SHELL ONLY.  SEE NOTES:BUILDING APPLICATION # 16016-20000-11934DEMO INT. OF (E) 2-STORY RETAIL SPACE INTO (2) RETAIL SHELL SPACES AT EACH STORY.  ADD ADDITIONAL FLOOR AREA BY INFILLING (E)ESCALATOR OPENING."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25920	17041-10000-02936	14934 W BURBANK BLVD 1-11	91411	4	174B149  1255	2250015050	(Q)R3-1, R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.17186	-118.45859	PC FO FA SYSTEM FOR 11 UNIT APARTMENT. TOTAL OF 58 DEVICES AND 1 POWER EXPANDER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25921	19041-10001-46900	9214 N HAYVENHURST AVE	91343	12	198B137   721	2676022003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	03/04/2020 12:00:00 AM	ADDRESS	34.23794	-118.4936	EXPEDITE FEESPV1, NEW ROOFTOP SOLAR SYSTEM, SYSTEM SIZE IS 14.5KWac/15.7KWdc, SCOPE OF WORK IS 50 MODULES (Q-CELL 315) WITH MICROINVERTERS (IQ7PLUS) LEADING TO A COMBINER PANEL. MAIN BREAKER HAS BEEN DERATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25922	13041-10001-12776	5711 W CENTURY BLVD GROUND	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	33.94573	-118.38128	PLAN CHECK FOR POWER ONLY. PROJECT IS IN PLACE OF ASSEMBLY. TITLE 24 PLAN CHECK UNDER APPLICATION NUMBER 13041-10000-12776. PERMIT WILL BE FOR POWER AND LIGHTING.****************************************************************13041-10000-12776 DESCRIPTION: PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ON A HIGH RISE. BALLROOMS ON GROUND FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25923	19041-10000-46327	100 N LA CIENEGA BLVD	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			Corrections Issued	11/12/2019 12:00:00 AM	ADDRESS	34.07466	-118.37629	T-24 PC FOR A RETAIL SPACE. SCOPE OF WORK INCLUDES ALTERATION OF EXISTING LIGHTS & ADDITION OF NEW SIGN LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25924	17041-20000-36388	4209 N WOODMAN AVE	91423	4	165B157   841	2266021018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM			Reviewed by Supervisor	10/16/2017 12:00:00 AM	ADDRESS	34.14674	-118.43077	ENERGY STORAGE SYSTEM. 13.5 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25925	12041-10000-26520	1330 N BAY VIEW AVE	90744	15	033B205    69	7420001021	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	33.78966	-118.27054	PV1 PLAN CHECK FOR NEW ROOF MOUNTED 3.6KW ENPHASE M215 MICROINVERTERS PHOTOVOLTAIC SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25926	15041-10001-20586	1455 N VAN NESS AVE	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM			PC Approved	01/04/2016 12:00:00 AM	ADDRESS	34.09728	-118.31598	01/04/15Changes to an approved set. All changes made under delta 2. Scope includes changes in conduit sizes, feeder sizes, and relabling transformers.Note: Permit pulled under PCIS#15041-10000-20586((((PC FOR POWER. UPGRADING 2 OPTIONAL STANDBY 750 KW AC GENERATOR AND ADDING NEW 1200 A SWITCHBOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25927	16041-10000-15850	1438 N GOWER ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.09714	-118.32212	PC FOR FA SYSTEM. 3 PANELS AND 39 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25928	18041-20000-05552	20821 W BERMUDA ST	91311	12	207B109   208	2706027028	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.26556	-118.58744	Plan check for a PV1 roof-mounted PV system. System size is 11.12 kWac and consists of (34) AC PV modules and (1) load center. Submitted per applicant request.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25929	19041-10000-13166	4201 W WILSHIRE BLVD #219	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.06189	-118.31911	T-24 PLAN CHECK FOR INTERIOR TENANT IMPRVEMENT ON EXISTING OFFICE SPACE IN A HIGHRISE. SCOPE INCLUDES NEW 45KVA TRANSFORMER, 2 x SUBPANELS, LIGHTING, CONTROLS AND RECEPTACLES.  TOTAL CONNECTED LOAD IS LESS THAN 400A. TOTAL AFFECTED AREA IS 4390 SQ.FTB#19016-10000-09184	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25930	16041-20000-12944	23345 W JONATHAN ST	91304	12	189B093    58	2020021029	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.21751	-118.63599	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (34) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25931	10041-20000-17852	8920 N RESEDA BLVD	91324	12	195B125   339	2769002005	C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	34.23255	-118.53589	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25932	13041-20000-08673	13170 N TELFAIR AVE	91342	7	225B141   198	2604002040	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.31	-118.47876	Plan check for energy and emergency lighting. Express permit is on 13041-20000-07382. Low-rise commercial.NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT TO (E) 2-STORY WAREHOUSE AND OFFICE BLDG.  (N) OFFICE PARTITIONS ON 1ST AND 2ND FLOOR REMODEL/UPGRADE (E) RESTROOMS TO CURRENT ADA STANDARDS, AND ADD A (N) OFFICE AND HANDICAP RESTROOM W/IN (E) WAREHOUSE AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25933	17041-20000-12250	524 E WASHINGTON BLVD	90292	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	PIN	34.02811119	-118.25991573	Interior restaurant TI (Panda Express) to include new panels, lighting, and outlets.  Plan check for power and energy per applicant's request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25934	10041-20001-03624	6724 W HOLLYWOOD BLVD	90028	13	148-5A185 146	5547012018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			PC Approved	05/10/2011 12:00:00 AM	ADDRESS	34.10139	-118.33715	Plan check only. Plan check for changes to load calculations, equipment changes, and layout changes on	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25935	19041-20000-06368	16970 W STRAWBERRY DR	91436	5	162B133    33	2292008033	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.14425	-118.50156	PLAN CHECK FOR NEW 6KW AC ROOFTOP PV SYSTEM ON EXISTING SFD. SCOPE OF WORK INCLUDES (22) HANWHA Q PEAK PV MODULES WITH INDIVIDUAL P320 OPTIMIZERS, AND (1) SE6000H INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25936	17041-10001-20496	6060 W HOLLYWOOD BLVD	90028	13	148-5A189 153	5545006030	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Issued	04/30/2018 12:00:00 AM	ADDRESS	34.10148	-118.32207	"Supplemental PC for power and energy for office space TI. This permit covers panelboards A, B, D and E which are connected to new 800A service located in adjacent building covered under (17041-10001-20564), feeders and installed at min. 24"" depth to panel F see siteplan. Installing new panels, lights, receptacles and equipment. T24 fees covered under master. B# 17016-40000-11249."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25937	15041-10000-31582	4140 S GLENCOE AVE 1-69	90292	11	108B153  1141	4230006006	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	33.98897	-118.4417	New fire alarm system to a 5 story apartment building, (265) f.a.  devices (1) power alarm panel(21) remote power supplies	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25938	14041-10000-32210	117 S BOYLE AVE	90033	14	129A221   232	5174013905	C2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			11/19/2014 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.04687	-118.22011	Full plan check for new appartment(4 stories) with partial first floor commercial(core and shell for commercial first floor).  Service size 2,500 Amps. Note: Variance to seperate fire alarm has been filed (11/19/2014)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25939	13041-10000-23958	9824 W NATIONAL BLVD	90034	5	123B165   967	4311005014	C2-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.0311	-118.40088	PC FOR ENERGY ONLY. permit to be pulled at EPC counter only. TI TO (E) STARBUCKS. LESS THAN 400A. 1313 SF. emergency lighting added	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25940	19041-10000-45782	6738 S ESPLANADE	90293	11	096B149   360	4116006097	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	07/13/2020 12:00:00 AM	ADDRESS	33.95947	-118.44949	[EPLAN] ADDING NEW 1 ESS TESLA BATTERY, 1 TESLA GATEWAY,  AND A 200A SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25941	14041-10000-29424	110 W 11TH ST	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.0392	-118.25858	CHANGE OF USE FROM LIGHT MANUFACTURING TO OFFICE (2ND FLOOR TO 7TH FLOOR). CORE AND SHELL ONLY FOR FUTURE TENANTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25942	11041-10000-27402	5849 S CROCKER ST	90003	9	108B205  1217	6006029001	[Q]MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.00	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	33.98846	-118.26863	"REMODELING OF EXISTING FACTORY/WAREHOUSE/OFFICES PLAN CHK IS FOR TITLE 24PERMIT FEE IS IN ""INSPECTION"" OF THE FEE PERIOD"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25943	10041-10000-21628	2000 S AVENUE OF THE STARS Suite 1060	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	T24 and emergency lighting plan check for suite 1060.  Install 3 new branch circuits and install 9 units to existing 277 lighting circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25944	17041-10000-19415	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Closed	11/28/2023 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR REWORK AND REROUTE OF 2000KW (480V) GENERATOR FEED FROM 1ST TO 2ND FLOOR SWITHGEAR.ALL EQUIPMENT IS EXISITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25945	15041-20000-38656	9107 W SAWYER ST	90035	5	126B169    28	4305028035	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Expired	12/26/2017 12:00:00 AM	ADDRESS	34.04537	-118.38831	"""0$ permit fees due to senate bill 1222""PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.0KWac. (42)MODULES-LG LG300N1K-G4(2)INVERTERS-ABB PVI-6000-OUTD-US-A(1) 100A SUBPANEL"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25946	17041-20000-42232	12242 N WINDMERE DR	91342	7	219B149   884	2507009031	(Q)RD3-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.29409	-118.4499	PV1.  Install 4.55 kW roof mounted grid tied PV system.  Central/string inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25947	18041-20000-19770	1738 S CHASTAIN PKWY EAST	90272	11	138B121   131	4431041019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.07423	-118.54729	PV1.  Install 16.1 kW DC roof mounted grid tied PV system.  (46) modules with 3.8 and 10.0 kW rated string inverters.  Main breaker derate.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25948	16041-20000-31410	14330 W COHASSET ST	91405	2	186B153   141	2215023006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.20647	-118.44557	PV1.  Install 4.8 kW DC roof mounted PV system.  Simplified central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25949	12041-10000-12174	918 S OXFORD AVE 1-225	90006	10	132B193   923	5093009032	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			05/25/2012 12:00:00 AM			PC Approved	06/11/2012 12:00:00 AM	ADDRESS	34.05538	-118.30763	Ti for common area of 5 story apartment. Plan check for energy and emergency lighting. 3055 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25950	12041-10000-28005	735 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2012 12:00:00 AM			PC Approved	12/13/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	Plan Check for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25951	13041-20000-05615	446-452 S LA BREA AVE	90036	4	135B181   520	5507009015	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.06547	-118.34378	Plan check for power. 600A service upgrade and two panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25952	14041-10000-29259	610 W CHILDS WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.01886	-118.28247	Full plan check for a new 5-story multi-use building for USC school. note to plan check engineer. customer came with a preprinted check, and customer still need to pay the remaning of 218 circuit breaker fee. --- PAID ON SUBMITTAL 2 11/5/2014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25953	15041-10000-04285	9644 N LURLINE AVE	91311	12	201B109   252	2748040013	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.24579	-118.58404	Plan check for Title 24 only. Project site is an existing building. Total lighting area = 14,700 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25954	19041-10000-06925	1243 W DENNI ST	90744	15	033B201   613	7415020029	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	33.78423	-118.2795	pc for pv system. system includes (21) modules (REC solarr: RETP2), (21) 320 solar edge optimizers, (1) LG chem 5kw battery, (1) solar edge 7600 inverter. (1) load panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25955	14041-20001-05170	12695 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	33.97727	-118.41529	Fee for expedite ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25956	10041-20000-05803	4648 W HOLLYWOOD BLVD	90027	13	147B197   451	5542014006	C2-1	Central	Hollywood	East Hollywood		1913.00, 1953.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	10/25/2010 12:00:00 AM	ADDRESS	34.10016	-118.29075	energy plan check  restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25957	10041-30000-00693	355 W 2ND ST	90731	15	018B201   777	7455016031	RD1.5-1	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	01/22/2010 12:00:00 AM		Permit Expired	07/27/2012 12:00:00 AM	ADDRESS	33.74223	-118.28441	TI - retail existing structure - Permit is for new ckts on existing panels.  P/C is for Energy and Emergency.3 OF 3 (10042-10000-01183)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25958	13041-20002-13571	12059 W VENTURA PL	91604	2	165B165  1242	2368002010	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM			PC Info Complete	05/13/2014 12:00:00 AM	ADDRESS	34.14469	-118.39458	((changes to approved set of plans. change includes relocation of items and addition of some items. ))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25959	13041-10000-29185	2000 E 1ST ST 1ST FLR	90033	14	127-5A221  39	5183008014	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			Corrections Issued	10/25/2013 12:00:00 AM	ADDRESS	34.04521	-118.21489	TITLE-24 PLAN CHECK ONLY FOR A 2-STORY MIXED USED BUILDING.  COMMERCIAL - BOTTOM, RESIDENTIAL - TOP. TI WORK IS ONLY ON THE FIRST FLOOR. TOTAL AREA IN SCOPE OF WORK IS 4716 SQ FT FOR INDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25960	18041-10001-37670	1533 N SCHRADER BLVD Hygiene-Bldg	90028	13	147A187    32	5547018901	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.09901	-118.33257	CHANGES TO AN APPROVED SET OF PLANS NOTED UNDER CLOUDED AREAS. SCOPE OF WORK INCLUDES RELOCATION OF PANEL HB AND ELECTRIC WATER HEATER TYPE. __________________________________New emergency temporary shelter for the homeless consisting of two separate state certified modular buildings-Admin Bldg; Hygiene Bldg  and newly constructed building -Membrane Bldg;This application is for the the wiring from the swbd to this building. Branch circuits inside this building will be part of the state certification.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25961	19041-10000-46737	15410 W VENTURA BLVD	91403	5	168B145   887	2283016001	C2-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.15415	-118.46933	PLAN CHECK FOR A NEW 800A 120/208, 3PH 4W WITH 4 x NEW SUBPANELS. TOTAL AFFECTED AREA IS 1,161 SQ.FT PER BUILDING PERMIT # 18016-10000-40959CHANGE OF USE FROM AUTO REPAIR TO CONVENIENCE STORE AS PART OF GAS STATION.  NEW FACADE AND STORE FRONT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25962	14041-20001-30428	661 E 90TH ST	90002	9	094-5A207  25	6042009020	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2015 12:00:00 AM			Re-Activate Application	05/06/2015 12:00:00 AM	ADDRESS	33.95482	-118.26317	Supplemental application for recheck of lost plans.  Roof mounted PV system with Enphase microinverter.  Total system size 4KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25963	11041-20000-21252	1111 S FIGUEROA ST 2ND FLOOR	90015	9	127-5A207 251	5138016913	C2-4D-O, PF-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	34.04338	-118.26581	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR INTERIOR TENANT IMROVEMENT TO EXISTING OFFICE AREA. PERMIT FOR ELECTRICAL WORK ON EXISTING CKTS. EXIT SIGNS ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25964	14041-20002-17037	5500 N KLUMP AVE	91601	2	174B173  1273	2350005016	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			03/30/2018 12:00:00 AM			PC Info Complete	03/30/2018 12:00:00 AM	ADDRESS	34.17012	-118.37509	CHANGES TO AN APPROVED SET. SCOPE INCLUDES CHANGING FEEDERS FROM COPPER TO ALUMINUM UNDER DELTA  A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25965	12041-20000-14539	15100 W VENTURA BLVD	91403	5	168B145  1071	2276006021	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.15292	-118.46192	Change of use from restaurant to CHASE bank.  Per applicant request, plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25966	15041-10000-32522	3903 W SUNSET BLVD	90029	13	145-5A203 371	5429013020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.09196	-118.27964	PC FOR ENERGY AND POWER. CHANGE OF USE TO RESTAURANT WITH MEZZANIN. TOTAL AREA  2931 SQ FT.B# 15016-10000-17322.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25967	14041-20001-11631	7900 W SUNSET BLVD	90046	4	147B177  1008	5554001001	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	34.09788	-118.36194	[12/31/14]]] PLANCHECK FOR T24 ENERGY PER INSPECTORS REQUEST. RIDE AID. PROVIDE PROPER CONTROLS AND OUTDOOR LIGHTING. 2008 T24 CODE.T. I. TO (E) RETAIL & ADD COFFEE/YOGURT AREA WITHINpc for T24 energy only. new lighting. per engineer, no work done with emergency lighting. emergency to remain. field verify integrety of existing emergency lighting.Note: Permit is under 14041-20000-28914	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25968	16041-20000-21802	8561 N MOREHART AVE	91352	6	192B165   150	2634022020	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.22589	-118.39896	PV1.  Install 8.4 kW roof mounted PV system.  Microinverter standard plan.  (30) modules with Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25969	17041-10000-01974	1901 W 8TH ST	90057	1	132A203   296	5142003024	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.05413	-118.27579	T24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, TOTAL AREA 11450 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25970	18041-10000-19943	728 E NOWITA PL	90291	11	108B145   841	4241020007	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	03/15/2019 12:00:00 AM		Issued	03/15/2019 12:00:00 AM	ADDRESS	33.99274	-118.4609	PC FOR INSTALLAION OF NEW ESS SYSTEM  (WITH EXISTING ROOF MOUNTED PV).SCOPE INCLUEDS 2 POWERWALLS WITH 2 NEW PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25971	19041-30000-52175	835 W BLOOM WALK	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	07/10/2020 12:00:00 AM		Permit Finaled	03/01/2021 12:00:00 AM	ADDRESS	34.01948	-118.2876	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE INCLUDES NEW  LIGHTING, CIRCUITS, AND CONTROLS, TOTAL AFFECTED AREA IS 920 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25972	12041-10000-17795	7901 N RUFFNER AVE	91406	6	189B137    53	2205009039	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.21434	-118.49699	Plan check T24 Energy/emergency lighting for baseball batting range addition.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25973	12041-10000-28649	2920 E OLYMPIC BLVD	90023	14	120A221   165	5170025004	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.022	-118.21502	PERMIT FOR BRANCH CIRCUITS, NON DWELLING POWER EQUIPMENT, AND A NEW TRANSFORMER. SINGLE STORY WAREHOUSE. PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25974	15041-20000-31202	5107 N GAVIOTA AVE	91436	5	171B141   393	2261025010	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Expired	10/25/2017 12:00:00 AM	ADDRESS	34.16234	-118.48164	PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service panel. (47) Hanwha BLK-G3 270W Modules(1) Solar Edge TL SE10000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25975	14041-20004-04466	2723 W 8TH ST	90005	1	132A201    11	5077020802	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.05787	-118.28484	05-21-15 Change to approved set of plan. Relocate Meter #1B and #1A to a new switch gear section. {{{{{{{{{Changes to approved set.  Relocation of 3 branch circuit loads (on LP1B and LP1A) and subfeeding 1 panel from another (LP2B fed from LP2A)  *****Previous Work Description*****  CHANGE OF USE; EXISTING 2-STORY RETAIL OVER PARKING TO CHARTER SCHOOL.BUILDING PERMIT 14016-10000-02954}}}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25976	18041-10000-23682	330 N FAIRFAX AVE	90036	5	138B177   336	5527037039	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	12/23/2020 12:00:00 AM	ADDRESS	34.077	-118.36127	PLAN CHECK FOR METHANE MITTIGATION SYSTEM FOR NEW 3-STORY, 28,023 SF OFFICE BUILDING OVER 2 LEVELS OF SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25977	13041-10000-04381	209 S 7TH AVE	90291	11	111B145   597	4240001021	RD2-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2013 12:00:00 AM			Corrections Issued	02/20/2013 12:00:00 AM	ADDRESS	34.00154	-118.47114	PV1 single story home. Total system size: 3.060KW. [Solar Module: Bosch Solar Module c-Si M 60. Model#: NA42117] [Inverter: Aurora Power One. Model#: PV1-3.0-OUTD-S-US].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25978	17041-20000-35580	16255 W VENTURA BLVD #625	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.15711	-118.48768	ti to an existing commercial building.  adding demising wall for two new suites.  energy check for indoor lighting only.  total square footage 346	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25979	15041-10000-23610	300 S SANTA FE AVE Space #N	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	Full plan check for a first time tenant, restaurant T.I located at a 6-story commercial building. Scope includes new lighting, equipment and receptacles; Total (38) circuits, (3) panels, (4) equipment and 3090-SQ feet for T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25980	14041-20000-20232	14542 W FOOTHILL BLVD	91342	7	228B149   741		(T)(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.32285	-118.45123	New roof mounted PV system with total size 3.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25981	13041-10004-12515	819 S SANTEE ST	90014	14	126A211    46	5145013005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Closed	11/17/2016 12:00:00 AM	ADDRESS	34.04107	-118.25233	02/112/16Changes to an approved set of plans. All changes are made under delta 6. Changes include removing the 1x4 lighting fixtures from the 2nd to 13th floors, replacing lighting fixtures, and adding a 25KVA Tranformer for a 15hp elevator. PC feeder conductors, transformer, and title 24. ((((((CHANGES TO PERMITTED SET OF PLANS; LOAD SUMMARY FOR SOME UNIT APARTMENTS USES 220.82 OF THE NEC. ALL CHANGES ARE CLOUDEDCHANGE OF USE OF AN EXISTING 93,379 SQFT, 13-STORY BUILDING W/ BASEMENT INTO JOINT LIVING AND WORK QUARTERS PER THE ADAPTIVE REUSE ORDINANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25982	14041-20001-06482	19961 W HEMMINGWAY ST	91306	3	189B113   721	2106003105	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.21413	-118.56867	(((change in plans. change in service interconnection. use of 100A existing panel okay. changes clouded. )))))Roof mounted PV system with size 3.5 KW.$0 permit fee for activity report. no permit fee required for this application)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25983	18041-10002-48197	434 S SAN PEDRO ST	90013	14	127-5A213 135	5147007020	PF-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	34.04473	-118.24336	"DELTA ""1"" CHANGES TO APPROVED PLANS. NUMBER OF PV PANELS WERE REDUCED FROM 36 TO 34 AND ADDED A PERFORMANCE METER AND A DISCONNECT SWITCH.<<<PLAN CHECK FOR ROOF MOUNTED 11.5KVA SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(TS208-5K75) WITH 36 MODULES(RECOM RCM-325-6MA(325W)) CONNECTED TO EXISTING 400A SERVICE>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25984	18041-10000-24017	10250 W SANTA MONICA BLVD # 1520	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for first time tenant retail space #1520 at Century City Mall. Total area: 2,880 sq.ft. Install (3) new panelboards, (1) 30kVA transformer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25985	16041-10001-00576	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Revisions to permitted set of plans. Changes on the plans are clouded and marked Delta 7 and include revision of frame sizes and trip settings for branch circuits circuit breakers.(((((((Full plan check for a T.I located in the 2nd and 3rd floor (TSA inspection room) of Tom Bradly LAX airport.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25986	19041-10000-31602	500-514 W 7TH ST 514	90014	14	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Info Complete	01/28/2020 12:00:00 AM	ADDRESS	34.04651	-118.25582	FULL PLAN CHECK FOR A TI TO A RESTAURANT. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 3900 SQ.FTB#19016-10000-23617	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25987	18041-10002-38075	12616 W SHERMAN WAY	91605	2	183B161    62	2324020034	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.20097	-118.40799	"SUPPLEMENTAL CHANGES TO APPROVED SET DELTA ""C"" ONLY. CHANGES IN LAYOUT AND LIGHTING FIXTURES. PC only<<<Tenant Improvement to existing Restaurant (Interior and Exterior). T-24 ONLY. BLDG PERMIT: 18016-10000-27310>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25988	19041-20001-49765	2520 N LAKE VIEW AVE	90039	13	148-5A209  90	5438008027	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			Reviewed by Supervisor	12/12/2019 12:00:00 AM	ADDRESS	34.10277	-118.25457	Expedite per applicant request. Plan check for Solar Voltaic Roof  Tiles (Solar Glass) and Energy Storage System, Solar Voltaic system size: 5.96KW with 102 Solar Voltaic Roof Tiles and 1 inverter(5.2KW) and 2 Battery(Tesla Power Wall 2.0)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25989	16041-20000-38501	22846 W VENTURA BLVD	91364	3	171B097   539	2042005065	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			Corrections Issued	10/31/2016 12:00:00 AM	ADDRESS	34.16531	-118.62473	New single story office building (car rental) and parking lighting.  Building permit filed uner 16010-20000-05013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25990	18041-20000-16706	11820 W SANTA MONICA BLVD	90025	11	126B149   466	4262005047	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Issued	06/26/2018 12:00:00 AM	ADDRESS	34.04251	-118.45838	First time tenant.  New pet retail space.  Plan check for power and energy - 2988 sq ftBuilding permit filed under 18016-10000-14242	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25991	18041-10000-48929	24030 S FRAMPTON AVE	90710	15	042B197   190	7439010016	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.8065	-118.30042	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25992	16041-20001-15934	2310 N CATALINA ST	90027	4	153B197   501	5588017026	RE11-1	Central	Hollywood	Los Feliz	Yes	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.11248	-118.29608	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.8 kWac and consists of (66) modules, (66) micro-inverters, and (2) load centers. (2) different module types are being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
25993	16041-20001-23657	10130 N TOPANGA CANYON BLVD	91311	12	204B101   367	2747017039	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM			PC Approved	08/23/2016 12:00:00 AM	ADDRESS	34.25473	-118.60582	08/23/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to EM lighting and a subpanel has removed. *****Previous Work Description*****Plan check Title 24 only in existing retail space T.I. Total area: 1,510 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25994	19041-10000-40794	940 E 4TH ST	90013	14	127-5A215 230	5163021001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.04337	-118.23511	CHANGE OF USE FROM WAREHOUSE TO ART GALLERY. AFFECTED AREA: INDOOR - 16,620 SFT & OUTDOOR - 5,130 SFT FOR A TOTAL OF 21,750 SFT.INSTALLING LIGHTS. T-24 ENERGY ONLY.BULDING PERMIT: 19016-10000-15123	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25995	18041-20001-18161	16741-16753 W SCHOENBORN ST	91343	12	192B137   231	2689012013	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM			PC Info Complete	05/10/2019 12:00:00 AM	ADDRESS	34.2228	-118.49793	"SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGES TO SINGLE LINE DIAGRAM AND ELECTRICAL SITE PLAN. CHANGE FROM 200A CIRCUIT BREAKER TO 400A CIRCUIT BREAKER, AND CHANGE FROM 200A SUB PANEL ""HC"" TO 400A SUB PANEL AND ADDITION OF A PROVISION NOTE.CLOUDED DELTA 5 CHANGES ONLY*original*Commercial service upgrade from 800A 480Y/277V to 2500A 480Y/277V.  Replacement of existing distribution."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25996	14041-20000-11219	20020 W MAYALL ST	91311	12	204B113   498	2726022005	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.25351	-118.56978	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 6.5kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(26) Trina Solar #TSM-250PA05.18 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
25997	18041-20000-40151	8742 N RANCHITO AVE	91402	6	195B153   899	2637001017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.22894	-118.43894	pv1install roof mounted pv system sized 10KW AC interconnected with msp.  system size 11.02KW DC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
25998	18041-10000-47760	10311 S LA CIENEGA BLVD	90045	11	090B173   271	4129031001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	04/28/2021 12:00:00 AM	ADDRESS	33.94269	-118.37026	T-24 ONLY, REMODEL & CHG OF USE TO AUTO REPAIR GARAGE. SCOPE OF WORK INCLUDES NEW LIGHTING, PANELS AND RECEPTACLES. SERVICE SIZE IS 400AMPS, TOTAL SQ. FT. 9110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
25999	11041-20001-20330	6333 W 3RD ST Stall 623	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM			PC Approved	09/28/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	Modification to an approved set of plans.  The modification is the change of the device being used as a current limiter for the track lights that are being used.  Plan check is for energy only.  <<<<<<<<<<Existing retail space.  New spice store to occupy space.  Stall number 623.  Plan check is for energy only.>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26000	19041-10000-00501	1925 S CENTURY PARK EAST 5th & 6th-Floors	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	INTERIOR TI ON 5TH AND 6TH FLOOR OF OFFICE BUILDING. T-24 ONLY. 20,824 SQR FT. BUILDING PERMIT: 18016-10000-37121	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26001	17041-20000-37891	11616 W HUSTON ST	91601	2	168B169   209	2354010009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.15938	-118.38607	addition of (2) tesla power walls.  plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26002	17041-10000-10199	601 N GRAND AVE	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural		2071.01	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.06097	-118.2438	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 16100 SQ FT. INDOOR/OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26003	14041-10002-26651	16542 W VENTURA BLVD Unit 120	91436	5	168B137   369	2284005025	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM			PC Approved	07/02/2015 12:00:00 AM	ADDRESS	34.1576	-118.49393	Change to approved set by mainly changing the control type. Note, all changes are under delta-4 only.(((Change to an approved set, all changes apply to delta-3 only.(((Full plan check. Medical office. Building application number 14016-10000-19503. TI  to convert commercial office to medical space in existing 5 story building. Installing new lighting, power, and communication systems. Fire alarm to be submitted separately.)))   )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26004	16041-10000-04817	2133 E VIOLET ST BLDG.A	90021	14	123A217    34	5166003010	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			Re-Activate Permit	05/10/2018 12:00:00 AM	ADDRESS	34.03269	-118.22873	FULL PC FOR NEW 2 STORY CREATIVE OFFICE BUILDING (BLDG A).  BUILDING 1 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26005	19041-20000-41536	6051 W MELROSE AVE	90038	4	141B185   584	5533036012	C4-1XL	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	34.08357	-118.33224	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK INCLUDES A SERVICE UPGRADE TO 600AMP, 120/240V, 1PH. NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26006	13041-20000-26707	17327 W BRONTE PL	91344	12	222B133   231	2601019021	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.30532	-118.51142	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 8.5 KW. 34 MODULES AND 2 INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26007	18041-10001-15718	2250 S MAPLE AVE	90011	9	121-5A207 259	5127014037	[Q]CM-2-O	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	34.02599	-118.26368	SUPPLEMENTAL TO CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE TO MODIFICATION OF LIGHTING SYSTEM UNDER DELTA 2 CHANGES ONLY ORIGINAL PERMIT PLANCHECK FOR POWER AND ENERGY. OFFICE AND WAREHOUSE.  55345SQFT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26008	18041-20001-20553	919 S HARVARD BLVD	90006	10	132B193   961	5093016024	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2125.01	Electrical	Electrical	Apartment			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.05521	-118.30434	Plan check for lost set of plan for project site is a new 5-story, 24-unit apartment building. Work includes a 1,000-amp service and a total lighting area of 12,420 sq. ft. Building application 17010-10000-04601Note: Permit shall be pulled under Master application.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26009	11041-20000-21090	5952 N VISTA DE LA LUZ	91367	3	177B085   363	2032003078	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2011 12:00:00 AM			Reviewed by Supervisor	10/19/2011 12:00:00 AM	ADDRESS	34.18013	-118.6655	New 8.32 KW roof mounted PV system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26010	19041-20000-41054	11881 W TERRA VISTA WAY #108	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/12/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26011	10041-20000-24477	820 S BURLINGTON AVE 1-21	90017	1	130-5A203 111	5142015004	R3-1	Central	Westlake			2094.03	Electrical	Electrical	Apartment			12/08/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	PIN	34.0525971	-118.2745913	fire alarm apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26012	12041-10000-03291	515 S FIGUEROA ST # 2040	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	ALTERATIONS IN OFFICE SPCES PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26013	17041-10000-42042	2546 1/2 N CORRALITAS DR	90039	13	148-5A211 196	5440029021	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM	02/22/2018 12:00:00 AM		Issued	02/22/2018 12:00:00 AM	ADDRESS	34.10044	-118.25192	PC for rooftop solar for new 7.6kW system. Installing 28 modules with optimizers and two central inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26014	14041-20002-01357	100 W WORLD WAY T1-Baggage	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	PIN	33.94684048	-118.40128468	Changes from previously approved plans.  Changes include relocate panel and chargers, upsize transformer, and install two new subpanels.  No change in lighting.  Plan check for power only.*****Previous Description*****New lighting, panels, and 15kva transformer in the baggage handling area of LAX Terminal 1.  FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26015	11041-10000-17017	11857 W SANTA MONICA BLVD	90025	11	126B145   385	4263032033	(T)(Q)RAS4-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.04239	-118.45956	T.I.  Exisitng office space in a single story building.  Relocation of the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26016	15041-20003-39933	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	12/1/2017CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 8.  CHANGES TO REFLECT FIELD CONDITIONS.THIS IS PLAN CHECK ONLY.  Full PC for new warehouse shell only, Scope includes New Xformer, elec.room, house panels and site lighting.2000 MSA, total area: 255,181sq.ft (uncondition+hardscape)((WHSE SHELL))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26017	14041-10001-17338	1443 N GORDON ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.09701	-118.32031	Revisions to approved set.  Change of feeder size, other miscellaneous distribution changes.  (((PC FOR POWER AND ENERGY. PARKING STRUCTURE. TOTAL AREA 11356 SQ FT. BLDG #14010 10000 01956:  PARKING STRUCTURE ADDITION,  5  LEVELS,   TOTAL AREA 113,561 SF)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26018	12041-10000-27880	7343 W 88TH PL	90045	11	096B157   809	4119022024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	33.95665	-118.42383	PV1 4.16KW ROOF-MOUNT ENPHASE MICROINVERTER STANDARD PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26019	11041-10000-09436	8706 W 3RD ST	90048	5	138B169   562	4334011008	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM			PC Approved	05/10/2011 12:00:00 AM	ADDRESS	34.0734	-118.38211	INSTALLATION OF OUTDOOR LIGHTING TO AN EXISTING RESTAURANT.  T-24, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26020	10041-10000-14655	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015004	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	12/14/2010 12:00:00 AM	ADDRESS	34.06259	-118.35341	T.I. to existing building for new Starbucks.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26021	15041-20001-31565	8500 W BEVERLY BLVD STE 623	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM			PC Approved	12/29/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	Revised on Time Clock (Lighting Control), Permit under 15041-10000-31565.*****T-24, TI TO A RETAIL TENANT INSIDE THE BEVERLY CENTER. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1494.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26022	17041-10000-40639	6305 N CLEON AVE	91606	2	177B173   123	2414002015	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Issued	11/09/2017 12:00:00 AM	ADDRESS	34.18516	-118.36824	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 6.54 KWDC /6.0 KWACSCOPE INCLUDES 20 MODULES WITH CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26023	19041-10000-11391	121 S HOPE ST	90012	14	132A211    37	5151002***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	34.05594	-118.25064	FIRE ALARM SYSTEM REPLACEMENT TO A LOWRISE (6 FLOOR) MIXED USE COMMERCIAL BUILDING. SCOPE INCLUDES NEW FIRE ALARM PANEL,  ANNUNCIATTOR, 18 POWER SUPPLIES AND 693 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26024	19041-20001-34260	6801 S PARK TER 530	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	33.97698	-118.39328	Plan check for Title 24 Energy only, new lighting in suite Tenant Improvement, this plan check covered lighting only, no outlets. Total area for lighting: 1,112 sq ft. B#19016-40000-22471	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26025	11041-20000-06937	12300 N GLADSTONE AVE	91342	7	219B161   303	2525028001	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.29325	-118.41006	New 600 amp service for an existing warehouse.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26026	17041-20000-07101	6600 N TOPANGA CANYON BLVD 10984g	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 698.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26027	15041-20000-31033	11942 W NEENACH ST	91352	6	195B169   508	2633017004	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.22799	-118.39274	Plan check for PV roof mounted system. System size: 11.0kW with 37 modules and 2 inverters(5.0kW and 6.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26028	18041-20000-28060	4111 S DON JOSE DR	90008	8	114B181   116	5028007029	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.01077	-118.35277	Plan check for PV roof mounted system, system size: 3.8kW with 16 modules and 1 inverter(3.8KW) connected to 400A Panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26029	13041-10001-35523	3769 N LIMESTONE PL	91403	4	162B149   386	2277031010	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	34.13953	-118.45851	Expedited RSES plan check per applicant request.{{PV1, Install 9 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US and Solaredge SE5000A-US. (36) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26030	11041-20000-09091	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Public Safety Only			05/04/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check for fire alarm panel and device upgrade to existing fire alarm system. Fire alarm system plan check fee was paid under #11041-20000-01687	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26031	15041-20000-15731	16611 W OLDHAM ST	91436	5	162B137   124	2291014033	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.14285	-118.49493	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (23) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26032	13041-20000-22600	901 S ABBOT KINNEY BLVD	90291	11	109-5A143 374	4286012008	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	33.9927	-118.47312	Plan check for energy and emergency lighting. Low rise office. Gunderson Dettmer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26033	19041-20000-42480	2020 S CENTRAL AVE	90011	9	120A211   451	5119001***	C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.02302	-118.25162	TENANT IMPROVEMENT ADD NEW LIGHTS P.C FOR TITLE-24 ONLY. TOTAL AFFECTED AREA 1,194 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26034	10041-10001-11911	219 W 7TH ST	90014	14	127-5A211  40	5144002025	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	10/29/2010 12:00:00 AM	ADDRESS	34.04504	-118.25277	REVISIONS TO PEMITTED SET OF PLANS- CHANGES IN THE LIGHTING SYSTEM ,INCLUDE MEZZANINE AREA, AND NEW PANEL BOARD.PLAN CHK IS FOR  TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26035	18041-20000-27200	24800 W EILAT ST	91367	3	177B085   617	2032026006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.17714	-118.66536	Plan check for a PV1 roof-mounted PV system. System size is 11.97 kWdc/11.35 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (38) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26036	19041-10000-28452	1200 W 7TH ST 5TH FLOOR	90017	1	130-5A207 646	5143006***		Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.05136	-118.26616	POWER AND ENERGY PLAN CHECK FOR A  T.I.  TO AN OFFICE SPACE. (LA CARE, 5TH FLOOR). SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 37349 SQ.FTB#19016-10000-21211	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26037	14041-10000-00175	5137 N FIGUEROA ST	90042	1	150A227   112	5468003020	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	34.10635	-118.19984	"PLAN CHECK FOR POWER AND ENERGY. 400 AMP SERVICE. FULL PLAN CHECK TO CLARIFY             MULTIPLE SERVICES. BUILDING P#  13010-30000-03244***BEGIN PRINT: 331285 (1/27/14 16:00)Application Number: 14041 - 10000 - 00175Address: 5137 N FIGUEROA-----------------------------------------------NO: 118129  -- ElectricalCode Enforcement Bureau has issued an order. This parcel iseligible for issuance of a 30 day time limit permit (includingBuilding, Electrical, HVAC and Plumbing) with a work descriptionas follows. ""COMPLY WITH DEPARTMENT ORDER effective date12/06/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation. Ifadditional assistance is needed, please call Inspector JOHNCORDON at (213)252-3981 of PROACTIVE CODE ENFORCEMENT 3.  CEISCase Number is 521944.(Created: IMSV7 / 11-27-13)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 118128  -- ElectricalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 12/06/2013 by Inspector JOHN CORDON at phone#(213)252-3981.  CEIS Case Number is 521944.Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.(Created: IMSV7 / 11-27-13)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~***END PRINT: 331285 (1/27/14 16:00)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26038	12041-20000-13120	11686 W TUXFORD ST	91352	6	192B169   433	2632023027	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.22279	-118.38707	commercial pv system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26039	12041-10000-10598	6600 N TOPANGA CANYON BLVD 1000B	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/15/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	Lighting and receptacle modification for an existing perfume (retail) space.  Load is 22A per applicant.  PLAN CHECK ONLY for Energy with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26040	19041-20001-00589	9432 N FARRALONE AVE pv1	91311	12	198B101   108	2727019018	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.2418	-118.61024	Revisions to approved set of plans.  Miscellaneous equipment rating and wiring detail changes.  PV system size details unchanged.  (((pv1install roof mounted pv system sized 13.5KW AC interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26041	16041-10000-38256	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2623.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			Reviewed by Supervisor	11/23/2016 12:00:00 AM	ADDRESS	34.08469	-118.4849	INFRASTRUCTURE FOR PARKING STRUCTURE ONLY OF A NEW 2 STORY RECREATION CENTER. PLAN CHECK 2 0F 2. BUILDING IS BEING SUBMITTED UNDER SEPERATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26042	19041-10000-34355	11308 W VICTORY BLVD	91606	2	180B173   910	2336016004	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Issued	08/30/2019 12:00:00 AM	ADDRESS	34.18652	-118.37727	NEW SPRINKLERS MONITERING STATION FA SYSTEM. SCOPE INCLUDES NEW FA PANEL, COMMUNICATOR AND 8 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26043	18041-10000-40948	17038 W ROSCOE BLVD	91325	6	192B133   268	2204033020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.22102	-118.50414	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.15KWdc / 8.463KWac.  (30)MODULES-HANWHA Q-CELL. Q PEAK-G4.1(30)MICROINVERTERS- IQ 7-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26044	18041-10000-31606	7107 S BROADWAY	90003	9	102B201   741	6012012043	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	33.97532	-118.27849	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26045	16041-20000-13253	16633 W VENTURA BLVD STE 700	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	Commercial office TI in (E) highrise office building.  Plan check for energy - 1860 sq ft.  Design build.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26046	18041-10001-45987	1513 W 216TH ST	90501	15	051B193   762	7349027020	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	33.83263	-118.3043	Plan check for a lost set of plan. Permit is already pulled under original application (((PV1. NEW ROOFTOP SOLAR WITH SYSTEM SIZE OF 5.490 KWpDC CONSIST OF 18 MODULES USING P300 OPTIMIZERS, 1 INVERTER 5KW(SOLAREDGE SE5000H-USRGM. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26047	13041-20001-24718	17904 W MONTAGUE CT PV-1	91344	12	219B125    19	2601063016	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.29849	-118.52522	"EXPEDITE FEES.<<INSTALLATION OF  GROUD MOUNTED PV SOLAR SYSTEM.  Building plans have already been approved.  System is Ungrounded and uses ""Power Optimizers"".  Plan Check only, Permit has already been pulled.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26048	19041-10000-21171	14916 W OXNARD ST	91411	4	177A149   120	2243022016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.17922	-118.458	Energy plan check for an office T.I located in a single story building. Scope includes new lighting and equipment with a total lighting area of 2400-SQ FT..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26049	18041-10001-01267	333 S GRAND AVE 41ST FLR.	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	Supplemental PC for T24 changes. Adding storage room lighting (6 fixtures). Changes clouded under delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26050	13041-10000-10115	12400 W BLUFF CREEK DR BLDG 10-11	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	33.97727	-118.4065	FIRE ALARM SYSTEM. 107 DEVICES. IN BUILDINGS 10 & 11	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26051	18041-10000-21988	2029 S CENTURY PARK EAST 10th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Issued	06/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN EXISTING RESTROOMS ON THE 10TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26052	17041-20000-02929	4700 W SUNSET BLVD 5/6 flr	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.09788	-118.29194	ti to an existing commercial space (consultation office only).  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 3184.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26053	16041-10000-38618	4730 N CRYSTAL SPRINGS DR	90027	4	162B197     1	5593002907	OS-1XL-RIO	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.13245	-118.28047	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTROOM SPACE. TOTAL AFFECTED AREA IS 420 SQ. FT.  B#15016-20000-09380 BASEBALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26054	16041-10000-45044	1925 W OLYMPIC BLVD	90006	1	130-5A203 221	5136008025	C4-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.05119	-118.27827	Plan check for power and energy in existing restaruant total connected load exceed 400A. Total area: 6,392 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26055	13041-10000-36024	6955 N RUBIO AVE	91406	6	183B137   292	2225006036	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.19711	-118.49576	PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (23) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26056	16041-10000-26727	633 W 5TH ST STE 1000	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY. T.I. REMODEL ON (E) COMMERCIAL BUILD. ON STE. 1000. TOTAL AREA 2025 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26057	16041-20001-15094	19401 W LONDELIUS ST	91324	12	195B117   106	2783025052	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.22997	-118.55595	06-24-16 Changes to an approved set of plans. Changes include remove some fixtures and switch out fixture 2x2 to LED down light. Changes apply to deta 1 {{{{{PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT AND CONVERSION OF PART OF WAREHOUSE INTO OFFICE. 1701 SQFT.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26058	12041-10000-08597	2160 E 7TH ST	90023	14	124-5A219 253	5171024006	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.03423	-118.22602	USING EXISTING BRANCH CIRCUITS IN NINE COOLER STORAGE ROOMS,INSTALLING COOLER-RATED LUMINAIRES, OCCUPANCY SENSORS, AND SWITCHES .INSTALLING STRIP LIGHTS ABOVEFOR MAINTENANCE PURPOSES.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26059	17041-20001-12949	19115 W STAGG ST	91335	3	189B121   595	2104010010	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.21119	-118.54975	Expedited plan check fee.  (((PV1.  Install 3.245 kW roof mounted grid tied PV system.  (E) 6 kW system is also on site.  (11) modules with 3.0 kW rated central inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26060	16041-20000-37628	726 E 78TH ST	90001	9	099B205   515	6023031024	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	33.96834	-118.26203	PV1.  Install 3 kW AC roof mounted grid-tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26061	18041-10000-34539	807 S LA BREA AVE	90036	4	132B181   244	5089022013	C2-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.06019	-118.345	PC FOR ENERGY ONLY, CHANGE OF USE FROM RETAIL TO BAKERY. SCOPE OF WORK INCLUDES NEW PANELS, CIRCUITS, AND LIGHTING. TOTAL SQ. FT. 1464.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26062	17041-10000-23267	9640 N OWENSMOUTH AVE	91311	12	201B105   205	2746015006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.24548	-118.60221	Plan check for power and Title 24.  T.I. and change of use from warehouse/office to motion picture production.  New 1,200 amp distribution panel.  Lighting area = 90,342 sq. ft.       Building permit #17016-10000-08963	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26063	17041-20001-45035	8937 N HANNA AVE	91304	12	195B101    62	2010021022	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.23311	-118.60683	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.10.12kW ungrounded system. (44) EnPhase IQ6-60 microinverters.(44) 295W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26064	18041-10000-04185	1755 W CLINTON ST	90026	13	138A207   120	5404009015	RD2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.07293	-118.26361	New PV1, rooftop solar system on SFD. System size 4kW AC/ 3.6 kW DC. (12) modules, (1) central inverter, (1) Rapid shutdown box	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26065	17041-20000-10449	1812 N MELHILL WAY	90049	11	135B133    58	4432011006	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.06764	-118.50063	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26066	16041-10001-39176	3150 W WILSHIRE BLVD STE 100	90010	10	132B197    39	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.06163	-118.29086	07/25/17Changes to an approved set of plans. All changes are clouded under delta 2. Changes include adding one circuit for MAU, revising floor plans, and revising panel schedules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26067	17041-20000-24806												Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM			Corrections Issued	07/27/2017 12:00:00 AM					N	N	Express Permit	06/10/2024 12:00:00 AM
26068	15041-10000-10578	8929 N OSO AVE STE B	91311	12	195B113    50	2781001017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.23333	-118.57549	in a storage area, replacing HID LUMINAIRES WITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26069	17041-20002-30167	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.21445	-118.48429	05-25-2018 Changes to an approved set of plan, Changes include remove part of the carport from plan. All changes has been clouded. Plan chcek only************************Provious Work description***************************Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size is 400 kWac. Ground-mounted portion of the system is 124 kWac and consists of (3) inverters, (404) modules, and (1) load centers.Note: Building permits for the ground-mounted carport system have been issued under building permits 17010-30000-03239/03464/03465. Roof-mounted portion of the system has application number 17041-20000-30164.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26070	19041-20000-12283	6150 N LAUREL CANYON BLVD H-150	91606	2	177B165  1100	2334011029		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	12/21/2020 12:00:00 AM		Issued	12/21/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first time tenant. Total lighting area = 1,985 sq. ft.Note: Building application has been generated under 19016-30000-09257	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26071	17041-20001-03721	13720 W VANOWEN ST	91405	2	180B157    55	2238010030	C2-1, R1-1, [Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.19378	-118.43188	plan check for energy indoor/outdoor only.  total square footage 3712.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26072	15041-10001-38333	1422 W MIRAMAR ST	90026	13	133-5A207 237	5153028016	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	34.05956	-118.2617	Supplemental PC for power for downsized service conductor. Changes clouded under delta 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26073	14041-10001-32528	5530 E VALLEY BLVD	90032	14	138A237    30	5221013038	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	ADDRESS	34.07423	-118.16225	CHANGES TO AN APPROVED SET OF PLANS.  CHANGE RATING ON PANEL F TO 80 AMPS.  CHANGES NOTED DELTA 1.  THIS IS PLAN CHECK ONLY.T.I to a design set with new load for gas dispensers connecting to circuit from previous design set.Note: previous design set (14041-10000-19956) is plan checked under Mehdi.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26074	13041-20000-05065	6651 N FALLBROOK AVE	91307	3	180B097   183	2038040013	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.1915	-118.62498	Plan for pool equipment due to related work under 12041-20001-22195.   Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26075	14041-10000-14407	1322 W 12TH ST	90015	1	127-5A205 103	5137030029	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.04457	-118.27267	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL  AREA3545 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26076	12041-10003-04381	4936 W FINLEY AVE PV1	90027	4	150B197   489	5589017050	R1-1	Central	Hollywood	Greater Griffith Park		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2012 12:00:00 AM			PC Approved	09/05/2012 12:00:00 AM	ADDRESS	34.10788	-118.29752	PLAN CHECK FOR INSTALLATION OF ROOF MOUNTED 9.75KW ENPHASE M215 MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26077	13041-20000-00285	5900 W WILSHIRE BLVD 22nd floor-1	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/04/2013 12:00:00 AM			PC Approved	01/04/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check energy and emergency lighting, spec suite. 22nd floor. 2445sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26078	12041-10000-18504	1626 S TRINITY ST	90015	14	123A209   326	5127002018	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.02996	-118.25785	"Adding a new ""communications hub"" to an existing warehouse space.  New 600A service, switchboards,  subpanels, and circuits.  Area is in a Methan Buffer Zone. (Generator is portable, optional standby)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26079	18041-10000-37375	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.01366	-118.28294	PLAN CHECK FOR ENERGY ONLY FOR REPLACEMENT OF EXISTING FIXTURES AND REPLACEMENT WITH NEW FIXTURES FOR OUTDOOR LIGHTING. TOTAL AFFECTED AREA = 119705SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26080	16041-10000-43963	601 W 5TH ST 3rd Floor	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Title 24 only in existing space  office T.I. Total area: 18,700 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26081	13041-10000-33746	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for power for tom bradley LAX project.Conduit stops for (5) future tenants.(Mehdi zandi)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26082	19041-10001-10881	8906 S HAAS AVE	90047	8	096A191   238	6036023002	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM			PC Approved	04/16/2019 12:00:00 AM	ADDRESS	33.95601	-118.31651	Revision to approved set as clouded on the plan, add 30A AC disconnect and revise the inverter placard to read 15A. This is plan check only, permit is covered under master #19041-10000-10881<<NEW ROOFTOP SOLAR SYSTEM CONSIST OF 14 MODULES (TSM 280) , 14 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.92KWdc and 3.8KWac>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26083	15041-30001-39699	16239 W NAPA ST	91343	12	192B137    37	2689024010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.2267	-118.48673	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect new inverter and modules with existing PV system.  Total system size = 6.6 kWac (3.6 kWac new).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26084	13041-20000-30139	14732 W OXNARD ST	91411	4	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.17918	-118.45422	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK IS IN THE BATHROOM ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26085	15041-10000-38820	1407 W 246TH ST	90710	15	039B193   351	7439018018	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	33.80188	-118.30234	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(20) KYOCERA 2656 MODULES.(1) ABB PVI-4.2 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26086	19041-20000-46364	1438 N GOWER ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	06/12/2020 12:00:00 AM		Permit Finaled	09/21/2022 12:00:00 AM	ADDRESS	34.09714	-118.32212	Replacement of site distribution equipment from (2) 1200A 4160V services under separate permit.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26087	18041-20000-21522	5745 W RODEO ROAD	90016	10	120B173   508	5047002061	R4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.02179	-118.37077	Installation of new transformer and distribution to supply pre-approved modular buildings.  Plan check for Title 24 Part 6 requirements for exterior lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26088	13041-10001-24535	1801 S HOPE ST	90015	14	124-5A205 177	5126011009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.03479	-118.26899	CHANGES TO APPROVED SET OF PLAN UNDER APP # 13041-10000-24535. DELTA 1 CHANGES ONLY. REVISIONS TO T24 PLANS UNDER INSPECTORS REQUEST.UNDER ORIGINAL:  TITLE-24 ONLY PLAN CHECK FOR A MORTUARY. TENANT IMPROVEMENT IS FOR A 1562 SF AREA IN A SINGLE-STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26089	17041-20000-23154	10285 W MISSOURI AVE	90025		132B157   499	4319009051							Electrical	Electrical	Apartment			07/10/2017 12:00:00 AM			Reviewed by Supervisor	08/04/2017 12:00:00 AM	ADDRESS	34.05829	-118.42113	Plan check for power and energy. Project site is a 4-story, 11-unit apartment building. Work includes a 1,000-service and a total lighting area of 17,315 sq. ft.Note: Building application has been generated under 13010-10000-03703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26090	19041-20000-13077	14613 W DEL PLAYA ST	91402	6	201B149   361	2650019024	(Q)RD2-1, (Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.24792	-118.45082	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26091	17041-10000-18151	900 N ALAMEDA ST 3rd floor	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC for new meduim voltage standby generator 2500kva 12.47kv with new feeder.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26092	16041-10000-41024	3025 S VERMONT AVE	90007	8	120B197   410	5054038023	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.02704	-118.2917	T-24, PC FOR ENERGY ONLY. CONVERT EXISTING RETAIL FOOD MARKET (775 SF) TO TAKE-OUT RESTAURANT (625 SF) WITH RETAIL PORTION IN FRONT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 828 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26093	10041-20000-24971	5303 N LANKERSHIM BLVD	91601	4	171B173   291	2350016006	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Issued	12/16/2010 12:00:00 AM	ADDRESS	34.16717	-118.37623	PLAN CHECK FOR 800A SWITCHBOARD TO EXISTING SERVICE AND NEW FEEDERS TO EXISTING PANELS. ALL LOADS ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26094	13041-10000-28429	2323 E 4TH ST	90033	14	126A223   299	5183013022	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.04095	-118.21213	CHANGE OF USE FOR TENANT SPACE FROM (E) RETAIL TO DENTAL CLINIC IN ONE STORY SHOPPING CENTER, 1,118 SF.  HEALTHCARE FACILITY PER NEC.  POWER AND ENERGY. CHANGES  on the plans: series combination for 200kA sym (cutle-hammer JJN with BA breaker, (E) 3/0 feeder, and  occupancy sensor added to small private office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26095	15041-10001-15359	3630 W WATT WAY	90089	9	118-5A201  14	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.02062	-118.28738	"((((6/2/2015))))RELOCATION OF AN EXISTING NORMAL LOAD PNL ""EHNB"" TO EMERGENCY LOAD DISTRIBUTION ""EDB1"". PLAN CHECK FOR POWER ONLY.  REMOVAL OF EXISTING NORMAL LOAD ON EDBLNB BOARD AND RECONNECT T-EDBLNB BOARD TO EMERGENCY GENERATOR.  PLAN CHECK FOR POWER ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26096	19041-10000-18548	7455 N GREENBUSH AVE	91605	2	186B157   273	2328027053	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.20617	-118.42627	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26097	15041-10000-25947	10131 N OWENSMOUTH AVE	91311	12	204B105   502	2747015058	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.25521	-118.60181	Change to approved set by derating the main breaker to 175-Amp.Permit requested per inspection-resizing main breaker from 200 to 175 amps. Permit fee is under inspectionReference to original plan check # 15041-20000-15778 (((Plan check for PV roof mounted system. System size 8.8kW system with 26 modules and 2 inverters(SB3800TL AND SB500TL) connected to load center 100A))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26098	17041-20001-16704	23856 W STAGG ST	91304	12	189B089   448	2027040034	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.21056	-118.64918	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 13.5 kWac and consists of (39) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26099	19041-10000-13880	11726 W SAN VICENTE BLVD STE 414	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Issued	04/16/2019 12:00:00 AM	ADDRESS	34.05328	-118.46625	T-24 PLAN CHECK FOR A TI IN AN EXISTING OFFICE SPACE IN A LOWRISE. SCOPE INCLUDES LIGHTING AND CONTROLS ON EXISTING CIRCUITS. TOTAL AFFECTED AREA IS 1272 SQ.FT. B#19016-40000-09423	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26100	19041-10000-35057	23556 W HATTERAS ST	91367	3	174B093   123	2041009013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM			Verifications in Progress	09/24/2019 12:00:00 AM	ADDRESS	34.17536	-118.64043	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 13.6KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SOLIS -1P10K-4G-US, SOLIS-1P3.6K-4G-US) WITH 49 MODULES(LG330N1C-A5) USING RAPID SHUT DOWN CONNECTRED TO EXISTING 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26101	16041-10002-38993	10250 W SANTA MONICA BLVD 2705	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"2nd Changes to approved set of ""Eataly"" noted under Delta 4, 5 and Delta SK2: add 2 panels K3L18 & K3L19, revise homerun for kitchen equipments, revise floor plan to indicate new circuits and removed circuits."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26102	13041-10000-14705	1080 N WESTERN AVE	90029	13	144B193   818	5536023023	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.09026	-118.30895	SUPPL. PERMIT TO PERMIT #13041-10000-14104 FOR CHANGE OF ADDRESS FROM 1018 N WESTERN AVE TO 1080 N WESTERN AVE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26103	14041-10000-35610	5711 W CENTURY BLVD	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	33.94573	-118.38128	Title 24 plan check only.  Total area = 3,770 sq. ft.Addition of new lights to prefunction area of hotel ballroom.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26104	10041-20000-11467	4617 W LEXINGTON AVE	90029	13	144B197   213	5542019023	RD1.5-1XL	Central	Hollywood	East Hollywood	YES	1913.00	Electrical	Electrical	Apartment			06/16/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	09/17/2010 12:00:00 AM	ADDRESS	34.09356	-118.28994	Plan check for 3.45KW Photovoltaic System for 2-Story Apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26105	17041-20000-32612	15012 W MOORPARK ST	91403	4	168B145   965	2264016077	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	ADDRESS	34.15358	-118.46005	New outdoor 800A 120/240V 1ph 3w service to supply 8 single family dwellings.Electrical permit for the SFDs issued under each unit's combination building permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26106	13041-10001-31525	11675 FLORENCIA WAY	91326	12	216B109    92	2701076062	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	PIN	34.28448756	-118.58530523	Expedited RSES plan check per applicant request.(((PV1, Install 4.75 kW DC roof-mounted solar array for a 2-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 19 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26107	14041-20000-30440	18561 W VICTORY BLVD	91335	3	180B125   633	2127009006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.18676	-118.53825	PV1Install a roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 4.515kW.21 EnPhase M215 microinverters connected to 21 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26108	14041-10000-34366	333 S GRAND AVE 43rd floor	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.05271	-118.25179	Title 24 plan check only.  Total area = 2736 sq. ft.Lighting renovation to common area on 43rd floor of existing commercial high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26109	13041-10000-25950	1007 N CYPRESS AVE	90065	1	145-5A219 146	5453023023	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			Re-Activate Application	09/19/2013 12:00:00 AM	ADDRESS	34.09358	-118.22535	"TITLE 24 PLANCHECK ONLY. 7703 SQFT. EMERGENCY LIGHTING. 1 STORY BUILDING.( DOLLAR TREE) PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.FROM BUILDING PERMIT : TENANT IMPROVEMENT TO EXISTING SPACE FOR NEW ""DOLLAR"" GROCERY STORE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26110	14041-10001-16483	13024 W WARREN AVE	90066	11	114B149   357	4244005011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	34.00993	-118.45165	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.335 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. ON TRANSFORMERLESS INVETER, WITH OPTIMIZERS.(17) MODULES: TRINA SOLAR # TSM-255PA05.18(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3800A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26111	19041-10000-05030	6390 W DE LONGPRE AVE	90028	13	147A187   290	5546016002	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Closed	02/19/2021 12:00:00 AM	ADDRESS	34.09602	-118.32852	PC TEMP POWER FOR A 20 STORY TRANSIENT OCCUPANCY RESIDENTIAL STRUCTURE HIGHRISE BUILDING. 193 APPARTMENTS. SCOPE INCLUDES NEW SERVICE (1000A), PANELS, CIRCUITS AND EQUIPMENT.SPIDER BOXES TOTAL AFFECTED AREA IS 82333 SQ.FTB# 16010-10000-05333podium and basement parking under separate permit (15010-10000-04706).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26112	14041-10002-34949	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.10311	-118.31242	REVISIONS TO PERMITTED SET OF PLANS: ADDED ON EACH OF SIX FLOORS  A CIRCUIT FOR A WASHER/DRYER; A CIRCUIT FOR FIRE SMOKER DAMPER; A CIRCUIT FOR OUTLET NEAR THE FIRE RISER. ALSO, A CIRCUIT FOR ONE BOOSTER PUMP (((((((Plan check for power and energy. Site is an existing 7-story senior-living apartment complex (site is not high-rise). Project includes a new 1600 amp service and associated unit panels. Total lighting area = 20,314 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26113	14041-20000-21443	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			08/08/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.19603	-118.45077	Plan check for power and energy (2008 Energy Code). New 49-unit apartment building, 3-stories. Fee calcs provided by applicant - verify. Fire alarm variance filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26114	18041-10000-38162	1150 S OLIVE ST 7TH FLOOR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.03962	-118.26181	PC FOR T-24 ONLY, INTERIOR TENANT IMPROVEMENT: SCOPE OF WORK INLCUDES NEW LIGHTING AND RECEPTACLES TO AN EXISTING SPACE. TOTAL SQ. FT. 14972.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26115	13041-20001-18841	14800 W VENTURA BLVD	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.15186	-118.45547	(((3/17/2014: CHANGES MADE TO APPROVED SET OF PLANS. ADDING UPM TO THE SYSTEM. THEY WERE MARKED FUTURE ON THE APPROVED SET. LISTING TO BE VERIFIED BY THE PLAN CHECK ENGINEER.)))INSTALLATION OF FUEL CELL SYSTEM. UTILITY INTERACTIVE. PC FOR POWER. 200KW RATING EACH FUEL CELL. TOTAL SYSTEM SIZE 1MW. NEW TRANSFORMER, 3 PANELS, 600V EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26116	19041-20000-14924	7541 N LINLEY LANE	91304	12	186B089   200	2027035031	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.20847	-118.6445	Plan check for PV roof mounted system, system size: 11.2KW DC, 10.296KW AC CEC with 32 PV Modules and 2 inverters(5.0KW and 6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26117	17041-10003-18656	2915 N CORDA LANE	90049	11	156B137    57	4490006039	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.12618	-118.48856	This is plan check only for revision to approved set, scope includes removal of the 200A load center, recalculating the available fault current based on the new electrical lay out.  Permit is covered under master# 17041-10000-18656<<Installation of (1) new 200A load center with (1) 5.8 kVA  Tesla AC Powerwall battery for an existing PV system.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26118	14041-20000-06762	19100 W OLYMPIA ST	91326	12	207B121   385	2728002025	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.26463	-118.54982	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26119	14041-10000-27052	380 WORLD WAY T02	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM			PC Info Complete	10/23/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for a retail store in the third floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26120	14041-20003-24071	9670 N DONNA AVE	91324	12	201B121   434	2762032029	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.24691	-118.54739	DUE TO SENATE BILL 1222 FROM 2012. PERMIT FEE 0$THIS IS SUPPLEMENTAL FOR EXISTING PERMIT. THIS APPLICATION IS TO SHOW INTERCONNECTION THROUGH SUBPANEL. RECHECK PLANS. NO PERMIT OFF THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26121	13041-10000-32182	746 W ADAMS BLVD EGC BLDG 2	90007	9	121-5A203   2	5123017008	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.02964	-118.27978	PLAN CHECK FOR TITLE-24 PART 6 ENERGY FOR A 2-STORY COMMERCIAL BUILDING. TOTAL AREA IN SCOPE OF WORK IS 3715 SQ FT. REMODEL OF EXISTING RECEPTION AREA, OFFICES, COMPUTER LABORATORY AND LOUNGE INTO NEW LECTURE HALL ( 1596 SQ. FT.), AND CLASSROOM SPACES; ALL WORK IS INTERIOR.E-PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER. NO CHANGE IN FLOOR AREA PROPOSED PER BUILDING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26122	19041-10002-18183	3420 N EAGLE ROCK BLVD A-C	90065	1	153A215    97	5457022020	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	ADDRESS	34.1145	-118.23591	PLAN CHECK FOR ENERGY ONLY, CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF SERVICE EQUIPMENT AND PANEL LABELING PER FIELD INSTALLATION. CIRCUITS HAVE BEEN UPDATED. ____________________________PLAN CHECK FOR TITLE 24 ONLY PLAN REVISION TO DIVIDE SPACE INTO THREE OFFICES. TOTAL EFFECTED AREA 6368 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26123	10041-20001-09479	10880 W WILSHIRE BLVD 2200	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Expired	10/15/2012 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check T-24 Energy general/emergency lighting. Emergency lighting existing. Tenant improvement- Rework existing lighting and switching. Permit for additional ckts not cover in original permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26124	18041-20000-02107	18000 W DEVONSHIRE ST 2nd Floor	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.25698	-118.52508	Conference room remodel in (E) commercial office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26125	17041-10000-07218	5321 W HOLLYWOOD BLVD	90027	4	148-5A195  63	5544009028	C2-1, D	Central				1904.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	PIN	34.10216125	-118.30619099	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 26100 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26126	17041-10001-01967	1051 S QUEEN ANNE PL	90019	10	132B185   753	5082001011	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2017 12:00:00 AM			Reviewed by Supervisor	01/30/2017 12:00:00 AM	ADDRESS	34.05558	-118.33003	Expedited Fees. ***********************PV1 roof mounted solar system with Tesla battery backup. Syste size: 7.6KW solar edge inverter with 8 solar modules. Variance has been issued for listing Auto-transformer under the app No. 50086.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26127	15041-10000-01023	202 W 1ST ST STE 411	90012	14	130-5A213  10	5149001006	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM			PC Approved	01/16/2015 12:00:00 AM	ADDRESS	34.05285	-118.24474	Plan check for energy only. Plan check only. TI to (e) offices in a high rise building. emergency lighting not in scope.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26128	19041-10000-43454	360 E 2ND ST 5th floor	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.04805	-118.24012	T-24 PLAN CHECK FOR A TI TO EXISTING OFFICE SPACE. SCOPE INCLUDES NEW 75A TRANSFORMER AND NEW PANELS CONNECTED TO EXISTING 400A SUBPANEL. TOTAL NEW CONNECTED IS LESS THAN 400A. TOTAL AFFECTED AREA IS 13,325 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26129	13041-10001-06722	1110 W 36TH ST PV1	90731	15	006B193    37	7469015013	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2013 12:00:00 AM			PC Approved	06/27/2013 12:00:00 AM	ADDRESS	33.71552	-118.30331	Supplementary submittal for plan check, original PV permit used isolation transformer inverters, new design uses transformerless inverters.  Plan check only.  {32 modules: Canadian Solar CS6P-250PX-BF} {2 transformerless inverters: Power-One PVI-3.6 and PVI-3.0}Originla Work Description: INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 7.84 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26130	19041-10000-08790	1700 N OLD RANCH ROAD	90049	11	135B137   551	4425023012	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	07/26/2022 12:00:00 AM	ADDRESS	34.06363	-118.49628	SERVICE UPGRADE FOR SFD. NEW SERVICE 600A 1PHSCOPE INCLUDES NEW SERVICE PANELS AND CIRCUITS. B# 17010-30003-01223	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26131	14041-10001-07906	11562 W MORRISON ST	91601	2	168B169    91	2354006024	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			Reviewed by Supervisor	04/09/2014 12:00:00 AM	ADDRESS	34.16023	-118.38429	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 13.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U(54) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26132	15041-10005-14888	1100 S HILL ST	90015	14	126A209   128	5139019034	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			02/27/2018 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	34.03989	-118.25984	PC FOR REVISIONS TO APPROVED SET TO REFLECT FIELD INSTALLATION. ALL CHANGES MARKED UNDER DELTA 22C.SCOPE INCLUDES RESIZING OF DOZEN CONDUCTORS TO DWELING UNITS. THIS IS PLAN CHECK ONLY!!	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26133	18041-10000-24329	6401 W HOLLYWOOD BLVD	90028	13	148-5A187 139	5546006003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.10177	-118.32972	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FORM RETAIL TO RESTAURANT. COFEE SHOP. 2303 SQFT. BUILDING PERMIT #18016-10000-19692	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26134	13041-20000-00414	4024 N RADFORD AVE PV2	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.14441	-118.39252	Plan check was paid for on 12041-10000-25544. Permit fee was charged for buildings 21, 22, 23 only. PV-2, NEW 502KW ROOF MOUNTED PV SYSTEM ON THE CBS STUDIO BUILDING. Permit for BUILDING 21, 22, 23 has been paid on a separate application. Please charge permit for buildings 9, 10, 11, 12 on inspection fee period.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26135	19041-10001-33703	2377 N JUPITER DR	90046	4	153B177   484	5569008012	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.11254	-118.36361	EXPEDITE FEESPV1 NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 13.2KWdc/12.6KWac. SCOPE OF WORK IS 40 MODULES (PANASONIC VBHN330SA17) WITH MICRO INVERTERS (ENPHASE IQ7X-960US) LEADING TO A COMBINER PANEL. NOTE: MAIN PANEL UPGRADE TO BE SEPRATELY PERMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26136	16041-10000-28136	307 N LA BREA AVE	90036	5	138B181   364	5525033032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.07647	-118.34435	Plan check for Title-24 only.  Total area = 720 sq. ft.  Renovation of existing car wash.  New equipment and indoor lighting in tunnel area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26137	18041-20000-43286	8724 N REMMET AVE	91304	3	195B105   208	2779041017	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Issued	11/13/2018 12:00:00 AM	ADDRESS	34.22893	-118.60011	Plan check for a fire alarm system for an existing commercial building. Fire alarm system consists of (1) FACP and (71) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26138	16041-20000-32549	2401 S HILL ST	90007	9	121-5A205 118	5126020006	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Closed	09/06/2018 12:00:00 AM	ADDRESS	34.02762	-118.26983	PLANCHECK FOR POWER ONLY.  SERVICE AND PANEL UPGRADE TO 800 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26139	16041-20000-44964	418 N NORTH FARING ROAD	90077	5	141B153    46	4358007015	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			Reviewed by Supervisor	01/25/2017 12:00:00 AM	ADDRESS	34.08616	-118.43257	Plan check for power. (N) One story storage building for mech. equipment at south side of the property (Accessory Building#7) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26140	18041-10000-11894	990 W FRANCISCO ST	90502	15	057B197    67	7351034067	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	33.8497	-118.29394	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26141	11041-10000-12894	8033 N VENTURA CANYON AVE	91402	6	189B157   263	2213019040	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Approved	10/20/2011 12:00:00 AM	ADDRESS	34.21682	-118.42885	lighting retrofit in a medical office Bldg. EPC is for T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26142	14041-20000-12439	141 E CANNERY ST	90731		015B205     4	7440029917	[Q]M3-1		Port of Los Angeles				Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM			Reviewed by Supervisor	06/20/2014 12:00:00 AM	ADDRESS	33.73857	-118.27091	NEW POWER SERVICE 600A  FOR EXISTING PARKING LOT WITH NEW PEDESTAL MOUNT ENCLOSURE ASSEMBLIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26143	14041-20000-31180	2413 W SAN FERNANDO ROAD 1st and-2nd Fl	90065	1	150B213   586	5457009001	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Issued	11/13/2014 12:00:00 AM	ADDRESS	34.10635	-118.23959	T.I. to existing building space on 1st and 2nd floors.  Install general lighting.  Plan check for energy only.Note: Permit is under this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26144	14041-10000-27918	870 W CESAR E CHAVEZ AVE	90012	1	133-5A213  27	5407003036	C2-2D	Central	Central City	Historic Cultural		2071.01	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	34.06186	-118.2457	TENANT IMPROVMENT FOR EXISTING RETAILSPACE T-24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26145	19041-10000-10476	1031 S BROADWAY 9TH FL	90015	14	126A209    99	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	06/07/2024 12:00:00 AM	ADDRESS	34.04041	-118.2583	Complete TI on the 9h Floor. Plan check for power & energy. Scope of work includes new lighting, receptacles and panels.   Area=16050	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26146	11041-10000-10700	1248 S ELDEN AVE	90006	1	129B197  1002	5076017010	R3-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			05/25/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.04777	-118.28755	NEW 8 UNITS. 4 STORY APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26147	12041-10000-16896	749 S CLOVERDALE AVE 1-6	90036	4	132B181   177	5089003034	[Q]R4-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			07/19/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.06097	-118.34693	Plan check for new fire alarm system. New 4 story 6-unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26148	17041-20001-42738	3231 N STEVEN DR	91436	5	159B141   212	2293014019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.13339	-118.48222	expeditepv1install roof mounted pv system sized 13.8kw interconnected with msp, battery back up system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26149	18041-30000-37468	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.04403	-118.2199	Plan check for New Fire Alarm system on existing commercial space. (1) FACP, (90) Devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26150	15041-10000-10051	3230 W SLAUSON AVE	90043	8	108B185   910	4005005028	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Info Complete	04/15/2015 12:00:00 AM	ADDRESS	33.98885	-118.32901	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 840 FOR A WAITING AREA AND ACCOUNTING ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26151	18041-10000-20592	2242 S KELTON AVE	90064	5	126B153   561	4322005010	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	06/16/2018 12:00:00 AM	ADDRESS	34.04169	-118.43241	New rooftop solar system PV1 on an (E) SFD, (17) AC modules, (1) 100A load center. System size 5.86 kW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26152	18041-20000-45566	13031 W JEFFERSON BLVD EMH-Production	90066	11	102B157    51	4211008039	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	33.97451	-118.42531	Plan check for power only EMH Production, addition load to standby generator. Panel L4C, L4C1, EP, and EL connected to 4G distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26153	14041-20000-16704	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.01768	-118.42494	Remodeling the Athletic Center for Windward School.  Install new branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26154	16041-20000-24406	22622 W VANOWEN ST	91307	12	180B097    33	2038020063	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.19355	-118.61959	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COMMERCIAL KITCHEN. 945 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26155	14041-10000-03732	11500 W OLYMPIC BLVD	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM			PC Info Complete	03/12/2014 12:00:00 AM	ADDRESS	34.03624	-118.44415	TI for a dental office. Electrical plan check per inspector request for power and energy. existing permit# 13041-30000-36196)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26156	10041-10000-25828	3962 W MARTIN LUTHER KING, JR BLVD UNIT#1	90008	10	117B181   606	5032007022	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	12/30/2010 12:00:00 AM	ADDRESS	34.01495	-118.34234	REPLACE/INSTALL LIGHTS, SWITCHES,  TO AN EXISTING CIRCUITS. EPC IS FOR ENERGY, T24 & EMERGENCY LIGHTS. UNIT#1 OF 4 (PERMIT WAS PULLED UNDER# 10041-10000-23248)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26157	10041-20000-16720	777 S FIGUEROA ST	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM			PC Approved	08/24/2010 12:00:00 AM	ADDRESS	34.04828	-118.26116	LIGHTING IN OFFICE AREA. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26158	18041-10000-05964	1339 N AVENIDA DE CORTEZ	90272	11	138B117   338	4431005029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.07166	-118.56009	PC FOR THREE ENERGY STORAGE SYSTEMS (TESLA POWERWALL) 40.5kWh IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (200A) WITH EXISTING PV SYSTEM (PER 702.12(D)(2)(3)(C))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26159	13041-10000-34299	9200 N OAKDALE AVE FLRS 1, 2-& 7	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Expired	01/06/2016 12:00:00 AM	ADDRESS	34.23811	-118.56674	PLAN CHECK AND PERMIT FOR T24 ENERGY. TI UPGRADES TO RESTROOMS .OFFICE BLDG.  OFFICE OCCUPANCY. HIGH RISE. 3056 SQFT , EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26160	15041-20001-00172	18654 W PARTHENIA ST	91324	12	195B121   416	2785002025	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.22809	-118.54008	Change to approve set of plan. (((T.I. to existing building.  Install indoor general/emergency lighting.  Plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26161	15041-20001-42766	17000 W ROSCOE BLVD	91406	6	192B133   263	2204033016	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	PIN	34.2208709	-118.50295585	[[[ 5/23/16 CHANGES TO APPROVED T24 ENERGY PLANS. ADDITION OF OUTDOOR LIGHTING ( 20,597 SQFT)AND CHANGES TO INDOOR LIGHTING.]]]PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR FOOD MART. 2040 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26162	17041-20000-34834	2238 S FEDERAL AVE	90064	11	123B153   313	4260015019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.03454	-118.44501	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26163	17041-20000-05835	4664 N DEL MORENO DR	91364	3	168B113   418	2174019014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	04/29/2017 12:00:00 AM	ADDRESS	34.15491	-118.57526	PV1 .  Install 3.9 kW roof mounted grid tied PV system.  (15) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26164	15041-20000-12916	17547 W GILMORE ST	91406	6	180B129   821	2229027003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.18777	-118.51596	Plan check for PV roof mounted solar array connected to 225A panel board. System rated for 6kWac with 20 modules and 1 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26165	19041-20000-21868	12039 N SUSAN DR	91344	12	216B137   175	2609009008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.28921	-118.49591	Plan check for a PV1 roof-mounted PV system. System size is 19.95 kWdc/14.4 kWac and consists of (2) inverters, (70) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26166	11041-20000-26016	1122 W WASHINGTON BLVD 2nd floor	90007	1	126A201   241	5135014042	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2217.10	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	PIN	34.03848469	-118.28242224	T-24 and emergency lighting plan check for the second floor of the building.  Inspector to please verify that the existing energy management system is T24 certified.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26167	13041-10000-24203	5421 W SANTA MONICA BLVD B	90029	13	144B193   700	5536010017	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1911.20	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.09092	-118.30761	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For retail suite B. 4 new lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26168	18041-20000-43624	8955 N QUARTZ AVE	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	34.23314	-118.56488	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26169	13041-10000-36174	113 S ROBERTSON BLVD	90048	5	138B169   406	4334001027	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.0748	-118.3839	permit to be pulled at EPC counter only. PC for energy only. 2 story. emergency lights.building application description: T.I. OF (E) RETAIL SPACE INCLUDING DOORS, CEILING, PARTITIONS, FIXTURES, LIGHTING, ETC, REPLACE (E) 4 SKLYLIGHT WITH SAME SIZE.  REPLACE STORE FRONT. 2,459S.F.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26170	14041-20000-03426	24554 W INDIAN HILL LANE	91307	12	186B085    91	2031014037	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.20486	-118.65772	Roof mounted PV system with Optimizer, system size 3.75KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26171	19041-10000-21602	161 E JEFFERSON BLVD	90011	9	118-5A205 232	5120005005	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Issued	06/07/2019 12:00:00 AM	ADDRESS	34.01794	-118.27071	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26172	10041-10000-20987	400 W PICO BLVD	90015	9	126A207   194	5134017006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.03884	-118.26465	TI IN AN EXISTING COMMERECIAL AREA.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26173	16041-20000-10979	7225 N IRVINE AVE	91605	2	183B169    38	2316030036	R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.20198	-118.38569	Install a roof-mounted solar array on a Duplex. Interconnect with a 200A MSP.System size: 3kW. Ungrounded system. (6) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26174	13041-20000-24221	11050 N YOLANDA AVE	91326	12	210B121   407	2717004017	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.27112	-118.54229	PV1 MICROINVERTER STANDARD PLAN. 30 PANELS AND 30 MICROINVERTERS. TOTAL SYSTEM SIZE 6.4KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26175	17041-10000-07755	19701 S VERMONT AVE	90502	15	057B197    41	7351034025	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.85153	-118.29072	PC for energy only. Removing and replacing HID fixtures with new LED ones. Area: 56,300	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26176	13041-10001-35638	8941 N TAMPA AVE	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	34.23285	-118.55413	CHANGES TO APPROVED SET OF PLANSRELOCATE SOME LOADS FROMmdp TO PANELs A AND Bcore and shell only for Ulta retail store. Separate permit for electrical to be pulled by tenant.PLANCHECK FOR POWER AND ENERGY FOR DEMOLITION FOR RETAIL STORE.  EXISTING RETAIL .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26177	16041-10001-29090	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Closed	08/28/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	"02/16/17Changes to an approved set of plans. All changes are made under delta ""DCN-34"". Changes include relocating/removing lighting fixtures,adding receptacles on the floor plans, and adding new circuits on panel schedule ""L4""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26178	16041-10000-04895	9730 N CEDROS AVE	91402	6	201B149   451	2650020003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.24702	-118.45176	PV1, new solar system on existing residential rooftop. Total system size is 4.2kWac system(16)Modules-SW285 Mono(1) Inverter-PVI-4.2-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26179	18041-20000-44391	13245 W RIVERSIDE DR SUITE #600	91423	4	168B157   316	2358014027	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Issued	11/29/2018 12:00:00 AM	ADDRESS	34.15778	-118.42187	Plan check for Title 24 only  in existing office space T.I. Total area: 4009 sq ft B#18016-20000-27559	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26180	10041-10000-01426	2000 E MARENGO ST	90033	14	132A223   107	5201014021	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2036.00	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	02/01/2010 12:00:00 AM		Permit Finaled	03/22/2011 12:00:00 AM	ADDRESS	34.05677	-118.20831	TI - existing Subway restaurant - Permit is for new ckts, new equipment, and new lighting/receptacles.  P/C is for Energy and Power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26181	14041-20000-31524	11459 N GOTHIC AVE	91344	12	213B137   630	2681003001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.27894	-118.48924	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size 6kW. Ungrounded system.28 255W pv modules across 3 strings (12 on inv1, 8+8 combined on inv2).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26182	18041-10000-16457	13259 N RALSTON AVE	91342	7	225B141    16	2501002028	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.31224	-118.47239	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26183	11041-10000-17476	13464 W WASHINGTON BLVD	90292	11	108B149  1835	4230003061	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM			PC Approved	11/15/2011 12:00:00 AM	ADDRESS	33.99079	-118.44634	TI TO AN EXISTING RETAIL BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26184	15041-10007-26434	1101 S FLOWER ST TOWER 1	90015	14	127-5A207 330	5138015***	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.04284	-118.26457	SINGLE LINE  REVISED TO SHOW THE RENAMING OF FLOOR LEVELS OF THE BUILDING PER OWNERS REQUEST(((((((PC FOR POWER AND ENERGY. NEW MIX USED BLDG 342 UNITS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26185	16041-10000-26297	1500 E 1ST ST	90033	14	129A219   112	5172004017	[Q]M1-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.04732	-118.2239	Plan check for T-24 only.  Remove exterior lights of HID fixtures and replace with new LED fixtures. Total affected area: 3,020 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26186	16041-20001-19003	3347 W SAN FERNANDO ROAD	90065	13	153B209   103	5458006002	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.11858	-118.24925	RSES expedited plan check fee per applicant request.  PV2.  Install 36 kW rooftop mounted PV system.  (126) 285 W modules with (1) 30kW rated central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26187	12041-10000-02671	22915 W VICTORY BLVD	91307	3	180B097   434	2038040031	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Expired	04/17/2014 12:00:00 AM	ADDRESS	34.1866	-118.62549	Ti in a Ralphs store. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26188	13041-10001-32323	4225 N SUNNYSLOPE AVE	91423	4	165B157   645	2360008020	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.14815	-118.42712	Expedited RSES plan check per applicant request.(((PV1, Install 2.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26189	14041-20000-22597	1200 N LA COLLINA DR	90069	4	144B165   183	4392016027	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.09238	-118.3956	Renovation of (E) 17,023 square feet single family dwelling.  Rewiring of house and new 1200A  service and service equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26190	16041-20000-26318	14300 W SUNSET BLVD	90272	11	129B133   181	4409012003	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	34.04996	-118.51146	New 2-story SFD.  Plan check for power.  (N) 800A 120/240V 1ph-3w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26191	13041-10000-35071	380 WORLD WAY space T71	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLANCHECK FOR T24 ENERGY ONLY FOR A PORTION OF A  FOOD & BEVERAGE CONCESSION IN LAX. SPACE (III FORKS). PLAN CHECK PER INSPECTORS REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26192	17041-10000-16179	1122 S MAPLE AVE	90015	14	124-5A209  83	5145023035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.03646	-118.25546	T24 ONLY, REPLACE (E) LIGHT FIXTUES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  38400 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26193	19041-10000-02193	5601 W MELROSE AVE	90038	13	141B189   262	5534035013	C4-1D	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.08366	-118.32247	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26194	16041-10000-16933	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	RENOVATE EXISTING ADMIRALS CLUB ON 4TH LEVEL AT TERMINAL 4; NO CHANGE OF OCCUPANCY, NO NEW SQ FT ADDED  26,317 SQ FTPC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26195	14041-10000-00099	12181 W BLUFF CREEK DR STE #200	90094	11	102B161  1150	4211010099	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	33.97788	-118.40638	REMODEL OF (E) OFFICE SPACE WITH ADDITION OF NEW OFFICES, CONFERENCE ROOMS, AND SERVER ROOM; INTERIOR TI. PROJECTED LIGHTING WORK IS APPROX. 38,456 SQ FT OF INDOOR CONDITIONED SPACE. NON-HIGHRISE, 4-STORY BUILDING; WORK DONE ON SECOND FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26196	10041-10000-18680	6310 N PLATT AVE	91367	3	180B093   913	2035008021	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Closed	03/02/2011 12:00:00 AM	ADDRESS	34.186	-118.64256	Title 24 and e-lighting. for carls junior.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26197	15041-10000-26878	1720 E 41ST PL	90058	9	114A213   204	5116026004	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.00687	-118.24243	new warehouse/office buildingPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26198	14041-10000-15146	11342 W HARTLAND ST	91605	2	183B173   226	2319006011	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.19508	-118.37818	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUPRESCENT FIXTURES. 10945 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26199	15041-20000-24163	11944 W OLYMPIC BLVD	90064	11	123B149   557	4259024001	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.03234	-118.45287	Title-24 plan check only.  Total area = 1,606 sq. ft.  T.I. to existing convenience store at Shell gas station.  New feeders and subpanels with less than 400 amps load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26200	10041-20000-12987	18427 W NORDHOFF ST	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	ADDRESS	34.23565	-118.53484	TI FOR HAIR SELON. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26201	18041-20000-23442	16255 W VENTURA BLVD #400	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.15711	-118.48768	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO THE (E) OFFICE SPACE TO ADD AND REMOVE PARTIONS. 2823 SQFT.BUILDING PERMIT # 18016-20000-18685	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26202	15041-10000-05300	12750 W RAYMER ST STE. 1	91605	2	186B161   550	2324004001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.20367	-118.40986	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  CHANGE EXISTING LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 7056.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26203	11041-20000-22760	10585 W SANTA MONICA BLVD #135 & 140	90024	5	132B157  1074	4326033042	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	12/20/2011 12:00:00 AM	PIN	34.05439965	-118.42928472	PLAN CHECK T24 ENERGY/ENERGENCY LIGHTING TI FOR ROOM #135 & 140. PERMIT FOR NEW CKTS AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26204	12041-20000-27073	10131 N VIKING AVE	91324	12	204B121   354	2729014034	RS-1	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.25424	-118.54034	Photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26205	14041-10000-17164	15300 W VALLEY VISTA BLVD	91403	4	166-5A145 216	2281005006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Expired	11/14/2016 12:00:00 AM	ADDRESS	34.14874	-118.46757	PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS.(42) MODULES: CANADIAN SOLAR CS6P-250PX(2) TRANSFORMERLESS INVERTERS: SOLAREDGE SE 5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26206	18041-10000-03928	1715 E DENNI ST	90744	15	033B213   283	7428005019	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.78592	-118.24074	PC for T24 replacing existing fixtures with LED. Total area is 65300sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26207	16041-20001-41855	7277 N GLENHAVEN CT	91307	12	186B089   579	2027049025	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.20386	-118.64865	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP. Derating the main to 175A. 10.56kW system. (33) 320W ac modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26208	19041-20001-27008	832 N COLE AVE	90038	13	141B185   109	5533028002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.0862	-118.32971	CHANGES TO APPROVED SET DELTA 2 ONLY. CHANGES APPLY TO LIGHTING FIXTURES. <<<Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from warehouse to motion picture production. Total lighting area = 1,550 sq. ft.Note: Building application has been created under 19016-10000-02811>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26209	15041-10003-03435	200 WORLD WAY #233	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	CHANGES TO AN APPROVED SET, NOTE CHANGES ON DELTA 5. SCOPE OF WORK INCLUDES EM LIGHTING FIXTURE AND RELOCATION OF LOADS. REF. MASTER APP. # 15041-10000-03435(((Plan check for power and title 24.  Total area = 550 sq. ft.Installation of new electrical distribution equipment (3 panels and 1 transformer in series) in airport space.  First time tenant.  New lighting and recepticles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26210	17041-20001-11435	189 S THE GROVE DR O-10	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			PC Approved	08/18/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	08/18/2017 Changes to an approved set. All changes have been clouded and marked as Delta 7. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****PC for outdoor Title-24. New lighting and power for a new canopy for an outdoor bar. Area: 382.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26211	12041-10000-17739	116 N KINGS ROAD 1-21	90048	5	138B173   556	5511010024	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			07/30/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.075	-118.37199	Plan check for power and energy. 21 unit apartment. 4980 sqft outdoor, 666 conditioned, 11872 unconditioned =17518 sqft. FIRE ALARM VARIANCE HAS NOT BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26212	11041-20000-00384	11666 W NATIONAL BLVD	90066	11	120B153  1008	4250008020	C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.02276	-118.43815	T.I. to existing building of a Whole Foods Market.  Install general lighting in Deli and Juice bar area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26213	16041-20000-21136	200 S GRAND AVE	90012	14	132A211    50	5149010***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.05408	-118.24993	PLANCHECK FOR T24 ENERGY. COLBURN SCHOOL CAFETERIA. 451 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26214	10041-10000-25149	662 N SEPULVEDA BLVD	90049	5	138B145    76	4368016009	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.07736	-118.4688	Ti in a restaurant. New service, panel board, and circuits. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26215	14041-20001-17941	14144 W VENTURA BLVD #200	91423	4	165B153   434	2266003092	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.14958	-118.44166	REVISIONS TO AN APPROVES SET OF PLANS. EXPANSION OF CONFERENCE ROOM #205, BREAK ROOM #204, STORAGE #203, AND FILE ROOM #202. ADDING NEW LIGHTING TO EXISTING PANELS. WORK TO BE PREFORMED ON THE SECOND FLOOR.Title 24 plan check only.  Building application submitted 6/20/2014.  Total area = 9,562 sq. ft.Demolition and installation of electrical recepticles and re-distribution of lighting system in existing commercial lowrise (building height = 54')	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26216	18041-20000-41591	14000 W VENTURA BLVD	91423	4	165B153   530	2266015007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Expired	12/04/2019 12:00:00 AM	ADDRESS	34.14884	-118.43737	Plan check for Title 24 only in existing space T.I. Total area; 1820 sq ft. B#18016-20000-33649	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26217	12041-10000-30004	380 W WORLD WAY level 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Recalculate fees since applicant brought check. (11->13 branch circuits)FULL POWER AND ENERGY. LAX. storage for the DUTY-FREE shops. 1ST TIME TENANT.  Located on level 4 back of the house. Methane. Separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26218	18041-20000-06688	9151 N ETON AVE	91311	12	198B105   155	2746010044	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.23718	-118.59411	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26219	17041-20001-16265	18740 W KIRKCOLM LANE	91326	12	216B121    86	2870007007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.29229	-118.54173	expeditepv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26220	16041-20000-04445	3033 E 11TH ST	90023	14	118-5A223  10	5170024016	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.02059	-118.21337	TI to (E) commercial office space in (E) commercial lowrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26221	18041-10000-34871	1640 S SEPULVEDA BLVD #120	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.04838	-118.44468	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. 3613 SQFT.BUILDING PERMIT #18016-10000-24885	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26222	19041-10000-44583	926 W JAMES M. WOOD BLVD	90015	14	129A207   181	5138005017	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	01/27/2020 12:00:00 AM		Issued	01/27/2020 12:00:00 AM	ADDRESS	34.04715	-118.2657	Temp' power plan check for a new ground up high rise building. Scope includes (1) 1000-Amp service. (3) panels, and other large associted equipment.((( per building application, Early Start Foundation only permit for a future new 18-story ,247 guest rooms hotel with one level basement)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26223	17041-10000-14285	1501 N SUMMITRIDGE DR	90210	5	147B157   193	4355005039	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.09868	-118.41997	Plan check for power.  Remodel and addition to single family dwelling.  New 800 amp 208/120 volt service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26224	10041-10000-22595	515 S FLOWER ST 30TH Flr	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM			PC Info Complete	12/07/2010 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI IN A COMMERCIAL AREA ON THE 30TH FLOOR. INSTALL A 400 AMP BUS PLUG, 800 AMP PANEL,  400AMP TRANSFER SWITCH & 400 AMP PANEL. NO NEW LOAD IS ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26225	18041-10000-43372	25420 S MCCOY AVE	90710	15	036B197  1146	7413024162	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	33.79301	-118.28975	NEW ROOF MOUNTED 2.24KW PV SYSTEM WITH 8 PV PANELS ON A SINGLE FAMILY HOME.BUILDING PERMIT: 15010-10000-04018 & 15010-20001-04018	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26226	17041-10000-38745	7001 WORLD WAY WEST Gate 130	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	33.94447	-118.41469	Install 2 @ 150KVA Generators and 2 @ 150HP Pump Motors in a non-classified area for Storm Drain at Gate 130 of LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26227	17041-10000-02750	3050 E 11TH ST	90023	14	118-5A223  32	5169006017	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.02017	-118.2131	"T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURE WITH NEW LED FIXTURES FOR EXTERIOR/INTERIOR USE. TOTAL AFFECTED AREA IS 43275 SQ. FT. ""Comply with department order effective date 06/30/2016. Permit will expire 30 days from issuance date."""	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26228	16041-20002-45393	10046 N SAMOA AVE	91042	7	202-5A199  24	2568006050	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.25157	-118.28721	11/14/17changes to an approved set of plans.  plans noted delta 1 and 2.  changes include updated plans to reflect field conditions.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26229	14041-10000-24977	9315 N RESEDA BLVD	91324	12	198B125   195	2763004005	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.23949	-118.53628	Title 24 plan check only. Remove HID light fixtures and replace with new LED fixtures. 4512 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26230	19041-10000-26362	3216 W SLAUSON AVE	90043	8	108B185   910	4005005028	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.98885	-118.32863	Replace fluorescent troffers with new led retrofit kits- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26231	14041-10000-00781	5403 W SUNSET BLVD	90027	13	147A193    61	5544022054	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.09828	-118.30729	Change of use from retail to Veternian clinic.  Newly connected load less than 400A, title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26232	10041-10000-17623	221 N WESTMORELAND AVE	90004	13	138B197   515	5501008024	M1-1	Central	Wilshire	Rampart Village	YES	2111.10	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.07516	-118.28805	Ti in an existing classroom. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26233	13041-10000-18139	1470 W 184TH ST	90248	15	060B193    72	6108015003	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	33.86368	-118.30204	PV1.  Install 5.886 kW garage roof-mounted solar array, interconnect into house main service panel (100A service).  {18 modules: SunPower SPR-327NE-WHT-D} {Transformerless inverter: PowerOne PVI-6000-OUTD-US }	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26234	15041-10000-31128	4155 W PICO BLVD	90019	10	129B189   891	5081001035	C4-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	34.04792	-118.32633	T-24, TI to an existing single story restaurant building (Gus' Fried). Existing Service of 800 amps, adding  new panels, lighting, and receptacles. PC for energy only. SqFt = 3200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26235	10041-10001-17322	7260 N OWENSMOUTH AVE	91303	3	186B105   909	2111019903	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.10	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	07/08/2011 12:00:00 AM	ADDRESS	34.20274	-118.60137	Permitted set was revised- the two services was replaced with a 800 120/240v 3ph 4 w service ; existing panel boards and HP units were connected to the new swbd; few changes to the loads on the panelboards and increase in size of two of the HP unitsCHANGE OF USE FROM LIBRARY  TO COMMUNITY CENTER/ CLASSROOM .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26236	14041-10000-03018	1420 N SAN PABLO ST	90033	14	133-5A225   6	5202004029	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.06151	-118.20315	PC for energy only. USC Parkview NEW PARKING LOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26237	18041-10000-25112	1035 N SWARTHMORE AVE #4-102	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	FIRST TIME TENANT IN A COMMERIAL RETAIL SPACE (SEE'S CANDIES). PLAN CHECK FOR POWER AND ENERGY. BUILDING PERMIT# 18016-10000-21447	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26238	19041-10000-50874	921 W VENICE BLVD	90015	1	126A203   113	5135030038	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM			Reviewed by Supervisor	01/15/2020 12:00:00 AM	ADDRESS	34.04013	-118.27572	POWER PLAN CHECK FOR. 2000A, 120/240V SERVICE. SCOPE OF WORK INCLUDES THE ADDITION OF PANELBOARDS.  **********************************************CHANGE OF USE FROM (E) WAREHOUSE TO NURSERY & RETAIL/MANUFACTURING/RESTUARANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26239	16041-10000-43101	3215 S BROADWAY	90007	9	118-5A205  43	5122006008	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Closed	01/12/2017 12:00:00 AM	ADDRESS	34.02027	-118.27333	PC for energy only. Remove HID fixture and replace with new LED fixture. Total area: 17805	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26240	11041-10000-12535	3560 W MARTIN LUTHER KING, JR BLVD UNIT 276	90008	10	114B185   217	5024009013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.01077	-118.33473	TI TO RESTROOM AND NEW 100 AMP PANEL TO EXISTING RETAIL SPACE IN CRENSHAW MALL.  UNIT 276.  PLAN CHECK IS FOR ENERGY ONLY, OTC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26241	13041-20000-18388	1701 N MORTON AVE	90026	13	142-5A211 332	5420027020	[Q]RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.08252	-118.25257	PV2 QUADPLEX. TOTAL SYSTEM SIZE 6.6 KW. USING TRANSFORMERLESS INVERTER. TOTAL OF 27 MODULES. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26242	13041-10000-33712	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Issued	01/29/2014 12:00:00 AM	ADDRESS	34.09818	-118.32309	TEMPORARY POWER  FOR TENANT IMPROVEMENT CONSTRUCTION FOR 4 SEPERATE BUILDINGS.Note: Approval of columbia square building (board MSRH) fed from the temp board for now is approved under 13041-10000-11563.  Once temp power is removed MSRH will be fed by it is own service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26243	17041-10001-46512	1118 N MCCADDEN PL	90038	4	144B185   681	5532021029	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.09129	-118.33733	PC FOR CHANGES TO APPROVED SET UNDER DELTA 4 (FOR FIRE ALARM).  SCOPE INCLUDES ADDING MORE DEVICE INCLUDING HORN STROBES AND SMOKE DETECTORS. TOTAL 88 ADDED DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26244	17041-10000-43479	1900 S AVENUE OF THE STARS #970	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for Title 24 only in existing T.I. office high rise. Total area: 3,491 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26245	18041-20000-45751	959 N SEWARD ST	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26246	14041-20000-35629	13051 N MEADOWLARK AVE	91344	12	222B133   178	2601019031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.30623	-118.51005	Roof mounted PV system with total system size 6.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26247	19041-20000-00074	18400 W RINALDI PL	91326	12	210B125    98	2715026057	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.27487	-118.53445	PV1.  Install 13.680 kW DC roof mounted grid tied PV system.  (38) AC modules.Fees $ 87.69 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26248	18041-10000-07483	1603 W 25TH ST	90732	15	009B189   138	7563016018	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	33.72304	-118.31334	PC for T24 only for replacement of indoor-outdoor existing fixtures with LED fixtures for Chase bank. Total area Indoor  is 16597sqft.Plan checker to verify address	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26249	14041-20000-03435	5240 N MEDINA ROAD	91364	3	171B105   640	2168003025	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Expired	04/28/2016 12:00:00 AM	ADDRESS	34.16436	-118.59903	Roof mounted PV system with Optimizer.  System size 7 KW.PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26250	15041-20000-37003	5727 N ALDEA AVE	91316	5	174B133   273	2255016008	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.17504	-118.5077	PV1, roof mounted solar panel 9.2kW(49) modules: #KU2656ZPA(1) Inverter: PVI-5000-OUTD-US-Z-A(1) inverter: PVI-4.2-OUTD-S-USStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26251	18041-20000-18426	14848 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.29452	-118.45468	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.87kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26252	15041-20000-23150	6533 N BELLINGHAM AVE	91606	2	180B165   490	2322005038	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.18955	-118.39886	Installation of new roof mounted solar PV array.  Total system size = 3.3 kWac.  Central inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26253	18041-10000-00977	7426 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.2054	-118.49418	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 26300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26254	18041-20001-35448	11420 N MONTALCINO WAY	91326	12	213B109   404	2701068015	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.2789	-118.58643	11-30-2018 Changes to permitted set of plan, changes include update as build existing service panel 200A. Changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26255	18041-20000-22245	14903 W BURBANK BLVD	91411	4	174B149  1220	2243010030	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.17231	-118.45779	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from auto repair to auto repair and food mart. Total lighting area = 1,381 sq. ft. Note: Building application has been generated under 18016-20000-08296.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26256	14041-20000-10595	764 S MARIPOSA AVE	90005	10	132B197   450	5094006001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.05797	-118.29858	New coin laundry.  New 800A service, panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26257	11041-10000-14734	10889 W LINDBROOK DR	90024	5	132B153   246	4363022009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	07/18/2011 12:00:00 AM	ADDRESS	34.05996	-118.4444	T24 lighting plan check for interior remodel of restaurant..  Building plan check approval pending.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26258	15041-10000-40827	14444 W LANARK ST	91402	6	189B149   106	2212002020	[Q]C2-1VL-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.21785	-118.44817	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH NEW LEDS.  TOTAL SQUARE FOOTAGE 4862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26259	15041-20000-39035	712 W 118TH ST	90044	15	084B197   275	6088023007	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	PIN	33.92631651	-118.28750083	PV1, roof mounted solar 3.8kW AC system.  (15)modules: SW280 Mono   (1)Inverter: SE3800A-US.  Power Optimizer is being used.   Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26260	17041-10000-26076	12239 W FOOTHILL BLVD	91342	7	213B165   158	2531003014	[Q]M1-1-CUGU	North Valley	Arleta - Pacoima	Foothill Trails District		1042.04	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Issued	08/01/2017 12:00:00 AM	ADDRESS	34.28194	-118.40268	TITLE 24 PLAN CHECK FOR REMOVAL OF (7) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA = 17500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26261	10041-10000-20220	6851 N VALJEAN AVE	91406	6	183B137   386	2224022025	M1-1, P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10, 1276.01	Electrical	Electrical	Public Safety Only			10/12/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.19538	-118.48602	REPLACING FIRE WARNING SYSYTEM-NEW DEVICES AND FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26262	18041-10000-47684	3260 S CLUB DR	90064	5	123B165   698	4316030025	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	02/09/2019 12:00:00 AM	ADDRESS	34.0328	-118.40233	Plan check for modifying number of strings, changing out an inverter and  changing all existing  module with  different model and an additional new module on an existing  plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26263	17041-10000-39231	2333 W SCOUT WAY	90026	13	138A205   117	5157013013	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.07287	-118.2705	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26264	10041-10000-21642	11444 W OLYMPIC BLVD 7th-FLOOR	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	12/28/2010 12:00:00 AM	ADDRESS	34.03654	-118.44363	TI IN EXISTING OFFICE AREAS ON 7TH FLOOR TENANT SPACES. PLA N CHECK IS FOR ENERGY AND EMERGENCY LIGHTHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26265	18041-20000-14807	20642 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.294	-118.58383	Plan check for PV roof mounted system. System size: 4.02kW with 12 AC Modules connected to MSP. B#16010-20000-05623	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26266	19041-20000-43468	982 N STONE CANYON ROAD	90077	5	144B149   138	4370021044	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM			Reviewed by Supervisor	12/10/2019 12:00:00 AM	ADDRESS	34.09207	-118.44794	New 600A 240/120V 1ph-3w service, distribution, power, and lighting for (N) buildings.  * Per building permit, project is SFD with at least (1) remote accessory building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26267	15041-10000-33030	818 W 7TH ST #720	90017	14	129A209    60	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.04895	-118.25943	Energy plan check for an office (STE-720) T.I  Scope includes new lighting and receptacles; Total area is 1575-SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26268	11041-10000-08891	12400 W WILSHIRE BLVD	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			Corrections Issued	04/11/2012 12:00:00 AM	ADDRESS	34.04157	-118.47031	TI TO EXISTING RESTROOMS IN A 10-STORY OFFICE BUILDING.  OTC PLAN CHECK FOR T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26269	17041-20000-23968	15940 W SKYTOP ROAD	91436	5	162B141   197	2286016002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.14078	-118.48015	pv1install roof mounted pv system sized 20kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26270	14041-20001-24878	7014 S HOOVER ST UNIT 2	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 2.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26271	13041-20000-13187	13311 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	PIN	34.31253789	-118.42511113	PV1 TWO STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 1.728 KW. MICROINVERTER STANDARD PLAN. [MICROINVERTER: ENPHASE ENERGRY M215-60-2LL-S22] [SOLAR MODULE: AU OPTRONICS- BENQ GREEN TRIPLEX PM250M00_260]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26272	14041-20000-34915	8750 N TAMPA AVE	91324	12	195B117   134	2784003058	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.22967	-118.55337	Plan check for power and energy. TI to retail 99 cent store. New panels and loads. Greater than 400 Amps. New lighting system. SQFT 20,458	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26273	17041-10000-03633	1327 N COLE AVE	90028	4	147A187   333	5546017904	PF-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.09565	-118.32999	PC for outdoor title 24. Removing HID fixtures and replacing them with new LED ones. Area:  12,625.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26274	17041-30000-30912	2101 N MOUNT OLYMPUS DR	90046	4	151-5A175  37	5569026007	RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM			Reviewed by Supervisor	10/04/2017 12:00:00 AM	ADDRESS	34.11049	-118.36713	Plan check for power only SFD 600A Service.Plan check onlyNote: Combination permit is under building permit.#16010-10000-00880	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26275	19041-20000-41743	1130 S WESTWOOD BLVD	90024	5	132B153   225	4363022007	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.06015	-118.44484	T24 PLAN CHECK FOR REPLACEMENT OF 2 OUTDOOR LIGHTS FOR EXISTING COMMERCIAL BUILDING. TOTAL SQUARE FOOTAGE = 50 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26276	12041-20000-24338	15840 W MONTE ST 108	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.31015	-118.47604	Plan check for energy and emergency lighting. Office space. Suite 108. VERIFICATION:  EMERGENCY LIGHTING REMOVED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26277	19041-10000-06623	1775 S BELOIT AVE 1-16	90025	11	126B149   144	4261019006	R4-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM	02/17/2021 12:00:00 AM		Permit Finaled	05/16/2023 12:00:00 AM	ADDRESS	34.04477	-118.44582	Full plan check for new 7-story, 16-unit, Apartment building over 1 level subterranean parking garage: Scope includes 1200-Amp 120/208v 3phase 4 wire with 6-typical unit.(B# 18010-10000-00323)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26278	14041-20000-30945	15853 W MONTE ST #108-C	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	10/03/2015 12:00:00 AM	ADDRESS	34.31022	-118.47637	T.I. to existing core/shell space of the storage building C (orinally no lighting and power installed in the existing core/shell space).  Install new panels and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26279	13041-10000-11345	380 WORLD WAY T54-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	New tenant space in Tom Bradley Intl Terminal, level 4, space T54-R for BLVGARI shop.  1051 sq ft.  Scope of work includes power and energy/lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26280	11041-20000-25325	24106 W CALVERT ST	91367	3	177B089   340	2045005012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03, 1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	03/20/2012 12:00:00 AM	ADDRESS	34.1822	-118.65212	10.26 KW PV system on the roof of a SFD, and service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26281	18041-20000-34498	20601 W CHESTNUT CIR #288	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.29238	-118.5839	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26282	11041-10000-04593	6401 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.18624	-118.59778	CHANGE OF USE FROM RETAIL TO GYM ( LA FITNESS )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26283	18041-10000-44584	4955 N CORBIN AVE	91356	3	171B117   546	2175014046	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Tarzana	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.1609	-118.56309	Permit Fee is $0 per AB 1414PLAN CHECK FOR ROOF MOUNTED PV SYSTEM(19KVA) CONSISTING OF 2 CENTRAL INVERTERS(SE7600H-US AND 11400H-US) WITH  70 MODULES WITH POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26284	10041-10001-15451	1300 E FACTORY PL Building-K	90013	14	126A215   235	5164008031	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.03904	-118.23584	Change the approved plan. Addition of a panel, X-former, and circuits. EPC is for delta 2 changes. ((((((3 storty commercial building. Existing Service, new Panels and circuites. Plan check for power and energy.)))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26285	15041-20000-04218	6316 N TOPANGA CANYON BLVD SUITE 2180	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	TI TO AN EXISTING COMMERCIAL BUILDING ( WESTFIELD TOPANGA CANYON). FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26286	14041-20000-30138	21857 W VENTURA BLVD	91367	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	PIN	34.16926375	-118.60275102	TI TO AN EXISTING SINGLE STORY COMMERICAL BUILDING. ADDING LIGHTING FIXTURES TO EXISTING POWER EQUIPMENT. 1587 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26287	19041-10000-15667	6033 W CENTURY BLVD 3rd floor	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	33.94572	-118.38954	Energy plan check only for TI, area of scope 1278SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26288	17041-10000-09750	431 S BURNSIDE AVE Garage# 6-Lot F	90036	4	135B181   326	5509005009	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.06636	-118.35098	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 94250 SQ. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26289	12041-20000-27605	1030 N ECHO PARK AVE	90026	1	139-5A209 635	5404019007	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM			Reviewed by Supervisor	11/27/2012 12:00:00 AM	ADDRESS	34.07474	-118.25842	New rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26290	18041-20001-37164			14	129A213    19	5161024034		Central				2062.00	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM			PC Approved	02/25/2019 12:00:00 AM				02-25-2019 Changes to an approved set of plan, Changes include modified ramp design, reconfigured lighting layout and receptacle location. All Changes has been cloued as delta 1. Plan check only. Permit for this change covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26291	12041-10000-06708	18831 W TOPHAM ST	91335	3	177B121   525	2127017008	RA-1-K	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.18068	-118.54357	New fire alarm system for an existing single story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26292	14041-10000-30216	12700 W MOORPARK ST TEMP	91604	2	165B161   326	2375007046	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Apartment			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.15012	-118.40957	Instalation of new fire alarm system for a new 4 story 12 unit apartment building.  67 devices + 1 control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26293	10041-10000-03677	9651 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	06/10/2010 12:00:00 AM	ADDRESS	34.24597	-118.5363	Tenant improvement in a restaurantplan chk is for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26294	15041-10010-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 38. PC ONLY. CHANGES TO FEEDER SIZES AND OTHER NOTES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26295	13041-20000-26347	10826 W KLING ST	91602	2	168B173   742	2421024019	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			09/23/2013 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.1555	-118.36671	pc for new apartment. 12 units. nonhazardous. new 1000A service. fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26296	19041-20000-16702	22135 W ROSCOE BLVD LOT #6	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	Plan check for PV roof mounted system, System size: 2.1KW with  7 PV Modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26297	18041-20001-03679	12143 N DELANTE WAY	91344	12	219B125    73	2601073004	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2018 12:00:00 AM			PC Approved	02/03/2018 12:00:00 AM	ADDRESS	34.29421	-118.5277	PV1.  Install 3.8 kW roof mounted PV system with (14) modules and 13.5 kWh energy storage system on 300A rated 240/120V residential service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26298	14041-10001-07764	155 W WASHINGTON BLVD Suite G4	90015	14	123A207    74	5126028010	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.03191	-118.26615	Supplemental plan check for restaurant TI on the 1st floor of an (E) commercial highrise building - missing set of plans at job site.  (((permit to be pulled at EPC counter only. PC for energy only. TI TO (E) RESTAURANT on the 1st floor in a high rise (03016 20000 06323?) [MODE-O-DAY BUILDING COMPANY retrofit=yes]. 100A service existing,  emergency lighting installed (Inspector to verify if generator is present). Less than 400A, relocating meter and panel within the storage room, per applicant.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26299	15041-20002-37188	4849 N VAN NUYS BLVD	91403	4	169-5A151  98	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.15918	-118.44892	07-05-16 Changes to an approved set of plans. Changes are relocation of receptacles and lighing due to structural changes. Changes apply to clouded  area only. {{{{{{{{{05/02/2016 Changes to an approved set of plans. Changes include the relocation of receptacles and light fixtures due to structural changes. All changes have been clouded. Everything else has remained the same.*****Previous Work Description*****TI to existing commercial building. Medical office TI. Plan check for power and energy. Total sqft. 3,900.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26300	13041-10001-35641	10420 S WEIGAND AVE	90002	15	090A217   266	6066009058	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	05/09/2014 12:00:00 AM	ADDRESS	33.94076	-118.22954	Expedited RSES plan check per applicant request.{{PV1, Install 7.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Fronius IG Plus A 7.5. (30) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26301	12041-10000-12644	3625 S VERMONT AVE	90007	8	120B197   967	5040029025	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	01/03/2013 12:00:00 AM	ADDRESS	34.0224	-118.29173	T.I. to an existing Radio Shack.  Load is less than 200A per plans.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26302	16041-20000-20715	7026 N TOPANGA CANYON BLVD	91303	3	183B101   272	2138002038	P-1VL-RIO, [Q]C1.5-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.19811	-118.60562	Plan check for power and energy. Project site is a new basement and 3-story self-storage building. Total indoor lighting area = 65,966 and total outdoor lighting area = 37,300 sq. ft.Note: Building application has been generated under 16010-10000-01399	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26303	12041-20000-06813	7800 N WOODLEY AVE	91406	6	189B141   290	2206009901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00, 1275.10	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.21161	-118.48344	Install outdoor general lighting in parking lot, canopy, and outdoor main entrance.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26304	19041-20001-43293	17323 W VENTURA BLVD	91316	5	171B133   685	2257016056	(Q)C4-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.16115	-118.51065	Expedited plan check fee.PV3.  Install 82.02 kW DC / 69.60 kW AC roof mounted grid tied PV system.  (228) modules with 100 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26305	17041-20000-40909	18415 W ALGIERS ST	91326	12	213B125   595	2870012013	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Closed	10/01/2023 12:00:00 AM	ADDRESS	34.27694	-118.53543	pv1install roof mounted pov system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26306	13041-10000-27283	8201 S GRIMSBY AVE	90045	11	099B169  1153	4105029005	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	33.96439	-118.37966	PV1. ROOFMOUNTED SOLAR ARRAY. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 3.76kW.(16) SOLARWORLD SUNMODULE SW255 MONO MODULE(16) ENPHASE M215-60-2LL-S22 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26307	18041-10001-00801	854 N VERMONT AVE	90029	13	144B197  1388	5539010021	[Q]C2-1	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM			PC Approved	09/25/2018 12:00:00 AM	ADDRESS	34.08686	-118.29152	PC FOR CHANGES TO APPROVED SET PER APPLICANT REQUEST. SCOPE INCLUDES CLARIFICATION FOR EXISITING SERVICE EQUIPMENT AND EXISTING GROUNDING. THIS IS PLAN CHECK ONLY! PERMIT PAID UNDER MASTER PC for T24 only for change of use from retail to restuarant. Installing new lights, receptacles and relocating panelboard.Total area is 1263sqft.B16016-10000-28991	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26308	10041-20000-15528	18600 W OXNARD ST	91356	3	177B121   614	2156006019	M1-1, P-1	South Valley	Encino - Tarzana	Tarzana		1393.02	Electrical	Electrical	Commercial			08/10/2010 12:00:00 AM			PC Info Complete	11/22/2010 12:00:00 AM	ADDRESS	34.17981	-118.53868	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM MANUFACTURING TO COMMERCIAL  SCHOOL.  NEW BLDG ELECTRICAL SYSTEM. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26309	17041-10000-01696	7285 W MULHOLLAND DR	90068	4	156A181   621	2428018008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.12018	-118.3513	PC FOR PV SYSTEM USING CENTRAL INVERTER 8.2KW AC AND 33 MODULES ON EXISTING RESIDENTIAL ROOF-TOP.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26310	16041-10000-25858	9801 N VARIEL AVE	91311	12	201B105   120	2746004033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.24832	-118.59306	Plan check for T-24 only on (E) commercial building. remove HID fixtures and replace with new LED fixtures,. Total affected area; 5,116 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26311	12041-10000-30678	601 S FIGUEROA ST 10TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	02/06/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING FOR TI ON THE ENTIRE 10TH FLOOR. HIGH RISE (ON GENERATOR). USING AREA CATEGORY ON 15776 SQ FT (<30,000). (NEW CONNECTED LOAD <400A)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26312	17041-10002-28776	976 E 55TH ST	90011	9	108B209   893	5103019001	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	33.99242	-118.25841	PC FOR REVISION TO APPROVED SET. SCOPE INCLUDES CHANGING ESS DISCONNECT MEAN TO REFLECT CODE COMPLIANCE (CHANGED TO FUSED DISCONNECT) AND REVISION TO CONDUCTORS DISTANCES OF PV AND ESS.. THIS IS PLAN CHECK ONLY! PERMIT FEE UNDER MASTER PERMIT. PC FOR PV SYSTEM WITH BATTERY STORAGE. PV SYSTEM RATED 3KW AC AND BATTERY UNIT RATED 5.8KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26313	12041-10000-17296	10504 W WILSHIRE BLVD	90024	5	135B157   424	4326003020	[Q]R5-3	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM			PC Approved	07/24/2012 12:00:00 AM	ADDRESS	34.06391	-118.43211	Plan check for energy and emergency lighting. TI to a kindergarten and a restroom. 3195 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26314	10041-10000-17652	1208 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.05018	-118.22673	Solar voltaic system installed on the roof of the building.  Consists of  6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26315	12041-20000-24316	448 S HILL ST Basement	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.04896	-118.25139	Plan check for power and energy. Basement and basement mezzanine. 9584 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26316	13041-10000-13311	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Info Complete	06/25/2013 12:00:00 AM	ADDRESS	33.94558	-118.4039	LAX TERMINAL 2 PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT AND INSTALLATION OF AN EXPLOSIVES DETECTION SYSTEM (FOR BAGGAGE) (CTX MACHINES). 6292 SQUARE FEET OF LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26317	14041-20000-22942	7422 N MADORA AVE	91306	3	186B113   522	2115013004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Expired	09/22/2016 12:00:00 AM	ADDRESS	34.20533	-118.56602	PV1.  Install 7.395 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26318	12041-10000-19674	22323 W PLUMMER ST	91311	12	201B101   575	2727009016	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.24286	-118.61321	New 10.08kw, rooftop, PV system for an existing SFR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26319	18041-20001-40236	1700 N SILVER LAKE BLVD	90026	13	144A205   215	5423022001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			Reviewed by Supervisor	10/30/2018 12:00:00 AM	ADDRESS	34.08936	-118.26831	Expedited plan check fee. PV1.  Install 13.68 kW roof mounted grid tied PV system.  (38) modules with (2) 7.6 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26320	14041-20000-16597	7500 N OAK PARK AVE	91406	6	186B133   444	2203023005	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.20666	-118.50493	PV1Install roof-mounted solar array on SFD. System size: 4.2kW(1) PowerOne PVI-4.2-OUTD-S-US-A transformerless inverter(14) SunPower 327W pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26321	17041-10001-05568	127 S SAN VICENTE BLVD 7TH FLR	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM			PC Approved	02/24/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	Plan check for Title 24 only in existing buildiing for office (temp construction office). Total area: 4,200 sq ft. Note: Permit was pulled under application number: 17041-10000-05568	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26322	13041-10000-25993	4410 N ROCHELLE PL	91316	5	165B133   121	2292017024	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.15132	-118.50845	PV1. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 11.44 kW DC. 44 MITSHUBISHI PV-MLE260HD MODULES, 44 ENPHASE 215 MICROINVERTER. 2 STORIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26323	18041-20000-00314	11801 W MISSISSIPPI AVE	90025	11	123B149   359	4262033020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.03444	-118.45125	Plan check for power only. Project site is an existing commercial building. Project scope is the connection of car lifts to the distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26324	19041-20000-21979	8917 W HILLROSE ST pv1	91040	7	207B189   623	2547014012	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.26375	-118.32614	pv1install roof mounted pv system sized 3KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26325	12041-10000-25990	24028 W CLARINGTON DR	91304	3	186B089   209	2027039021	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2012 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.20833	-118.65087	13.08 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26326	19041-10000-23568	3804 S WISCONSIN ST	90037	8	117B197   661	5037018024	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.0164	-118.29296	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26327	11041-10006-23452	20600 W VENTURA BLVD South-1-217	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			05/13/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	DELTA 14 MINOR  REVISIONS TO PERMITTED SET OF PLANS- ALL CHANGES ARE CLOUDED(((((((((South Building of a New 217 unit Apartment building.  Building Permit is on 11010-10000-01956	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26328	09041-10001-24136	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005019	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	05/23/2012 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.15303	-118.39667	CHANGES TO PERMITTED SET OF PLANS: ADDED 80KVA UPS, AND CRAC UNITS FOR NEW ITE ROOM. DISTRIBUTION BOARD WAS UPGRADED FROMM 600A TO 800A. LIGHTING FIXTURES REMAINED THE SAME(((((((((NEW  PRIVATE SCHOOL BUILDING ; VARIANCE WAS FILED TO SEPARATE THE FA PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26329	18041-20001-03479	2735 N LA CUESTA DR	90046	4	156B177   679	5570002001	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.12104	-118.35657	Plan check for a PV1 roof-mounted PV system with battery storage. System size is 10.4 kWac and consists of (2) inverters, (35) modules, (2) load center, and (2) PowerWalls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26330	19041-20000-23228	17624 W CORINTHIAN DR	91316	5	168B129   347	2290011045	RE11-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.15819	-118.51713	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 13.86KW DC/11.781 KW AC. SCOPE OF WORK INCLUDES (42) PANASONIC PV MODULES WITH IQ7X MICROINVERTERS AND A ENPHASE COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26331	15041-10000-11393	1110 S WESTERN AVE #201	90006	10	129B193   694	5080010002	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.05041	-118.30886	TI for (E) 810 sq. ft. commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26332	15041-20000-16013	639 W 32ND ST	90007	9	120A203    49	5123010023	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.02416	-118.2801	TI to existing commerical building (Fire house studio). Plan check for power and energy. Adding new lighting including emergency. New 600A service. Total Sqft. 5108.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26333	14041-10000-35243	6929 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.19659	-118.49256	Title 24 plan check only.  Total area = 7,420 sq. ft.Remove HID light fixtures and replace with new fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26334	18041-10000-01014	14006 W RIVERSIDE DR #30	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	"Plan check for T24 only, TI on an (E) restaurant to be reuse as ""85 Degree C Bakery"". Install new lights and receptacles, add new load < 200A.B#18016-10000-00785"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26335	12041-10000-30721	12422 W BLUFF CREEK DR bldg 2	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	33.97704	-118.40702	t.i. of building 2 of school campus. constructing office spaceShell of main service was approved under seperate plan.  Loads mainly comes from mechnaical equipment,building 2 located in methane zone.  No penetartion made is thru the membrane.  Main service is provided with seal off.  When load is added to empty panels, plan check is required again.  Variance to separate fire alarm plans submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26336	14041-20000-14817	9350 N ETON AVE	91311	12	198B105    64	2746010016	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.24087	-118.59542	Plan check for energy only. Lighting (incl. emergency) for office space in existing single story building. 3,545 sqft. Applicant returned to plan check due to inspector requesting different lighting fixtures. Permit was obtained under a previous/separate application: 14041-20000-14170	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26337	17041-10000-09168	6904 S LA TIJERA BLVD	90045	11	102B173   202	4103010004	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	33.97579	-118.37323	Plan check for Title 24 only in existing space T.I. Total area: 3190 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26338	16041-30001-18529	1745 S STANLEY AVE	90019	10	126B177   389	5069014009	R1-1	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	34.04358	-118.36388	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (1) inverter and (15) panels. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26339	15041-20000-18909	5437 N NEWCASTLE AVE	91316	5	174B129   989	2162002038	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.16973	-118.5245	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 37 KW.(120) CS6X 310 MODULES(3) SMA SB11000Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26340	12041-10000-24142	610 S LEVERING AVE 1-18	90024	5	135B149   341	4363011010	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			10/10/2012 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.06654	-118.45286	NEW 4-STORIES  18 UNITS APARTMENT BUILDING. Fire Alarm Variance has Been Filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26341	16041-10000-45615	315 N WILMINGTON BLVD bldg 5	90744	15	027B205   659	7417010937	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM				PC for new Fire Alarm with 41 Devices and 2 Fire alarm panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26342	13041-10000-12867	380 WORLD WAY Space T23	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			Corrections Issued	05/16/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 700 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Short  Cake).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26343	13041-10000-04074	238 E VERNON AVE 1-9	90011	9	112-5A205  69	5109011045	R3-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Apartment			02/15/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	ADDRESS	34.00356	-118.27038	T24 ONLY FOR PERMIT THAT HAS ALREADY BEEN ISSUED. PC FOR ENERGY, TOTAL AREA 6420 SQFT. INSTALLATION OF EMERGENCY LIGHTING IN GARAGE AND COMON AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26344	15041-10000-16277	12745 W CASWELL AVE	90066	11	111B153  1027	4236018024	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Info Complete	03/04/2016 12:00:00 AM	ADDRESS	33.99823	-118.43744	PC FOR POWER AND ENERGY. NEW APARTMENT BUILDING WITH 4 STORIES AND 8 UNITS. TOTAL UNCONDITIONED AREA 9033 SQ FT + 1779 SQ FT OUTDOOR LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26345	14041-10001-08937	1447 S SIERRA BONITA AVE	90019	10	129B177  1050	5069019036	R2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.0481	-118.35953	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26346	16041-20001-04268	10635 N OAKDALE AVE	91311	12	207B113   116	2708020031	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2016 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	34.26366	-118.5674	PV1.  Install ground-mounted 40 kW PV system.  (4) Frnonius Primo 10.0-1 inverters with (130) LG315N1C-G4 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26347	11041-10000-13483	408 S MAIN ST #101 &-#103	90013	14	129A213   162	5148008001	[Q]C4-2D	Central	Central City			2073.02	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM			PC Approved	06/30/2011 12:00:00 AM	ADDRESS	34.04781	-118.24728	T.I.  Existing restaurant occupy unit #101 and #103 on the first floor of high rise building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26348	14041-20001-20238	20140 W DELITA DR	91364	3	171B113   241	2166010020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM			PC Approved	08/07/2014 12:00:00 AM	ADDRESS	34.16494	-118.57323	Expedited plan check fees.  PV1.  Install 8.16 kW roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26349	05041-20006-23388	1717 N VINE ST	90028	13	148-5A187 104	5546004400	C4-2D-SN	Central	Hollywood	Hollywood United		1902.00, 1910.00	Electrical	Electrical	Apartment			05/11/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.10222	-118.32701	Plan check power for exterior emergency lighting per LAFD requirments. Normally off emergency lighting exempt from T-24 Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26350	18041-10000-22375	555 E RAMIREZ ST	90012	14	132A217   238	5409021900	PF-1XL-RIO	Central	Central City North			2060.20	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.05425	-118.2309	PLAN CHECK FOR TITLE 24 ONLY FOR PARKING AREA - TOTAL AFFECTED AREA = 7238 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26351	15041-10000-31137	2029 S CENTURY PARK EAST 32nd-33rd floor	90067	14	132B161   697	4319016029	C2-2-O, C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24 to an exististing commercial building. Adding Newl lighting and receptacles to restrooms only in the 32nd and 33rd floor. Total sq. ft. 790.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26352	18041-20002-45468	12208 N DELANTE WAY	91344	12	219B125   107	2601074014	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	34.29569	-118.52793	Revisions to approved plans.  Reduction of subpanel AIC from 22kAIC to 10kAIC based on submitted fault current calculations attached to plans.  (((Plan check for PV roof mounted system, system size: 19.140kW DC, 17.875kW AC wtih 58 PV Modules and 2 inverters(7.6kW and 10.0KW) connected to 400A Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26353	12041-20000-01328	2029 S CENTURY PARK EAST #200N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to existing high rise building on 2nd floor.  Install general/emergency in conference and office areas (south end).    Plan check energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26354	16041-10001-09084	1383 N MURCHISON ST	90033	14	132A227    19	5202011050	(T)(Q)C1-1VL	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Info Complete	10/03/2016 12:00:00 AM	ADDRESS	34.05771	-118.197	Revision to the approved set of plan. Changing from delta connection 240V to star connection 208 V (adddition of two 75kva transformers). This is plan check for Power only noted as Delta-7.Note: Electrical core and shell has been permitted under 13041-10000-19886>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26355	16041-10000-39646	1119 W M ST	90744	15	033B201   132	7415003018	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	33.78872	-118.27706	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.92KWdc / 9.75KWac.(39)MODULES-CANADIAN SOLAR CS6K-280M(39)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26356	18041-20000-21371	21600 W HART ST	91303	3	183B105   682	2138007019	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.19726	-118.60086	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26357	19041-10000-08668	1550 W 35TH PL	90018	8	120B193  1082	5041011902	OS-1XL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.02356	-118.30447	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26358	17041-20001-06959	7324 N HYANNIS DR	91307	12	186B093   529	2027015018	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM			PC Approved	03/14/2017 12:00:00 AM	ADDRESS	34.20403	-118.64053	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.56 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26359	18041-20000-45831	3844 W 27TH ST	90018	10	123B185   933	5051015002	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Apartment			12/03/2018 12:00:00 AM	08/29/2023 12:00:00 AM		Issued	08/29/2023 12:00:00 AM	ADDRESS	34.03108	-118.32685	1000A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26360	18041-20000-32460	10754 W WALNUT DR	91040	7	201B177   119	2542029008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.24984	-118.36466	PV1.  Install roof mounted PV system sized 14.75 kW AC interconnected with main service panel.  Energy storage system.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26361	17041-10000-03427	4470 W COLISEUM ST	90008	10	117B181   290	5045001904	C2-1, PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.01777	-118.34541	PC for outdoor title 24. Removign HID fixtures and repalcing them with new LED ones. Area: 34,225 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26362	15041-10003-07426	13215 W OTTOMAN ST	91331	6	195B157   158	2627014023	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM			PC Info Complete	05/21/2015 12:00:00 AM	ADDRESS	34.23396	-118.42091	((((5/21/2015))))changes to an approved set of plans.  deration of the main ocpd to 175amp.  load calcs provided with plans set.Change to approved set. derated the main circuit breaker to 150A. The applicant provided the load calculation for derated the main circuit breaker*****Changes to approved set.  Inverter changed from Power One UNO-7.6-TL to ABB PVI-6000.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (27) modules and (1) inverter. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26363	19041-20000-40188	14606 W ISLA VISTA DR	91402	6	201B149   891	2650019064	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.2474	-118.45063	PV1. INSTALL 3.15 KW DC PV SYSTEM WITH (9) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26364	17041-20000-18331	6333 N WOODMAN AVE	91401	2	180B157  1062	2239006042	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Apartment			06/01/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.1858	-118.43144	New fire alarm system for 4-story apartment building.  (151) notification and signaling line devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26365	16041-10001-35999	10250 W SANTA MONICA BLVD # 1625	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Approved	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Changes to an approved set of plans, changes include circuit change and fixture changes.  (((Full PC for New Tenant ""Compartes Store"" Ste. 1625.  Install new Xrfmr, and  panels < 200A, total area 407 sq.ft)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26366	19041-10000-47142	7900 S LOYOLA BLVD GER	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Issued	12/02/2019 12:00:00 AM	ADDRESS	33.96604	-118.41693	"TI IN AN EXISTING OFFICE  AREAS ON THE 2ND FLOOR OF ""GERSTEN"" BUILDING (GER). INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 1,218 SFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26367	16041-10002-42684	10250 W SANTA MONICA BLVD # 2800	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM			PC Info Complete	03/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"""CPK"" changes to approved set of plan noted as Delta-9.  Changes include: Added show window receptacle (LP1-12) and adjusted the total demand load; Revised load on KP1-73,75,77; Revised lighting schedule.**This permit is also include one circuit under plan check# 16041-10003-42684"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26368	17041-20000-16913	8515 S KANSAS AVE	90044	8	097-5A197 290	6033014039	[Q]C2-1, [Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.96038	-118.2942	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR NEW 3-STORY CHARTER HIGH SCHOOL. 1 FACP AND  187 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26369	15041-20001-17661	11965 W MONTANA AVE 1-49	90049	11	129B141   303	4265007078	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			09/27/2016 12:00:00 AM			PC Approved	09/27/2016 12:00:00 AM	ADDRESS	34.05133	-118.47199	9.27.2016 - Plan check for modifications to approved set. Add double-pull section outside. Main distribution panel updated. Changes clouded delta 2.======Plan check for power and energy. Project site is a new 49-unit apartment building. Build has 6 floors of tenant spaces and 2 levels of underground parking. Work includes (1) 2500-amp service, (14) meter sections, (51) unit and house panels, and associates loads. Total common indoor lighting area = 46,717 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26370	19041-20000-42020	22704 W SYLVAN ST	91367	3	177B097   158	2039019026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	03/09/2021 12:00:00 AM	ADDRESS	34.18442	-118.62132	Plan check for Energy storage system only, existing PV system. Total energy storage system size: 54KWh, (4) Tesla Power Wall 2.0, (2) new sub panels back up Gate Way.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26371	11041-10000-14259	5138 N FIGUEROA ST	90042	1	150A227   145	5468005042	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			Corrections Issued	07/08/2011 12:00:00 AM	ADDRESS	34.10602	-118.19965	T.I.  Existing 7-11.  Replacing flourescent light fixtures with LED fixtuures in retail area.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26372	11041-10000-08338	600 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	INSTALLING NEW EQUIPMENT AT LAX TERMINAL 6.  59 NEW MOTORS FOR CONVEYOR SYSTEMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26373	19041-20000-31341	5824 S CIMARRON ST	90047	8	108B189  1515	6001002023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	33.98835	-118.31556	PV1. INSTALL 3.10 KWDC/2.83 KWAC SYSTEM WITH (10) MODULES AND OPTIMIZERS(P320) AND (1) INVERTERS(SE3800) ON EXISTING 100 SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26374	17041-20000-02053	6300 W WILSHIRE BLVD Suite 860	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for Title 24 only. Project site is suite on the 8th floor of an existing high rise building. Project scope is a tenant improvement. Total lighting area = 2,621 sq. ft.Note: Building permit has been pulled under 16016-10000-29233	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26375	18041-20000-00617	10390 W SANTA MONICA BLVD #330	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.05734	-118.42365	Plan check for power and energy. Project site is a suite within an existing commercial building (dental office). Project scope is a tenant improvement. Total lighting area = 1,247 sq. ft.Note: Building application has been generated under 18016-20000-00421	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26376	14041-20000-01479	7812 S BROADWAY 1-5	90003	9	099B201   464	6031020002	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.02	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	33.96849	-118.27809	CHANGE OF USE FROM CHILDCARE CENTER TO A COIN LAUNDRY. NEW 800A SERVICE. EVERYTHING IS NEW. BUILDING PERMIT SUBMITTED IN 2013	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26377	18041-10000-24141	2956 S CRENSHAW BLVD	90016	10	120B185   357	5051028024	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.02782	-118.33491	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26378	14041-20000-26220	9741 N NITA AVE	91311	12	201B101   285	2727007006	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Expired	10/18/2016 12:00:00 AM	ADDRESS	34.24773	-118.61394	CENTRAL STRING INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26379	17041-10000-21944	6500 W WILSHIRE BLVD 2ND FLR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.06371	-118.3703	Title 24 plan check.  Remodel of existing conference room 215 with new lighting and receptacles.  Total area = 512 sq. ft.Building permit #17016-10000-14498	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26380	16041-10000-05064	5050 N CHICOPEE AVE	91316	5	171B129   356	2257018026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.1628	-118.51222	NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222. ((((PV1, SOLAR ROOF MOUNTED SYSTEM USING CENTRAL INVERTERS. (62) MODULES AND (3 - 7.7KW) INVERTERS. TOTAL SIZE 23.1 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26381	12041-20000-30173	13301 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	PIN	34.31253789	-118.42511113	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26382	13041-10000-28865	3901 N EAGLE ROCK BLVD BLDGC	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	11/02/2013 12:00:00 AM	ADDRESS	34.11925	-118.23127	"INSTALLING FIRE ALARM SYSTEM,   APARTMENT BUILDING ""C"" (3 OF 7 buildings). plans expedited per applicant request, under submital 2"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26383	18041-10001-44970	8240 N BELLINGHAM AVE	91605	2	192B165   581	2309020024	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM			PC Approved	02/07/2019 12:00:00 AM	ADDRESS	34.22088	-118.39862	SUPPLEMENTAL CHANGES TO APPROVED SET ADDING A NEW BREAKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26384	14041-20000-21311	17954 W VENTURA BLVD	91316	5	171B129   258	2182001008	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.16407	-118.5239	Replacement of existing fluorescent ceiling fixtures with LED can lights in a commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26385	18041-10000-09217	17107 W VENTURA BLVD	91316	5	168B133    17	2258012028	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.16046	-118.50575	Alterations for at a Chase bank- replacing outdoor and indoor luminaires with LED type using existing branch circuitstotal affected area 88887 sq.ft. PLAN CHECK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26386	13041-20000-23226	9458 N RUFFNER AVE	91343	12	198B137    65	2687015018	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.24269	-118.49693	New ungrounded PV system with two inverters.  Rooftop, single family dwelling.  Plan check is for PV System only, NOT for Service upgrade or derating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26387	18041-10001-15617	4500 N WOODMAN AVE 124, 207,-301	91423	4	168B157   929	2360002030	R1-1-RIO, R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.15306	-118.43102	SUPPLEMENTAL PLAN CHECK ONLY FOR T-24 ENERGY. TENANT IMPROVEMENT. SCOPE INCLUDES NEW PANEL, LIGHTING AND RECEPTICAL. TOTAL AFFECTED AREA IS 12306 SQ.FT. ((THIS IS PLAN CHECK ONLY, PERMIT IS COVERED UNDER MASTER #18041-10000-15617)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26388	16041-20000-44959	418 N NORTH FARING ROAD	90077	5	141B157    12	4358007015	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			Reviewed by Supervisor	01/25/2017 12:00:00 AM	ADDRESS	34.08616	-118.43257	Plan check for power. (N) One story  accessory living quarter at north side of the property (Accessory Building#4).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26389	16041-20000-40952	10250 ANGEL LANE	91331	7	204B165   429	2537004039	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25692827	-118.40436292	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26390	14041-10000-14667	401 S OCEAN FRONT WALK 1-45	90291	11	109-5A141 128	4286029001	R3-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	33.99386	-118.47965	T24 ONLY FOR A 3 STORY COMMERCIAL BUILDING. NOT HIRISE, WITH EMERGENCY LIGTHING. TOTAL AREA 2600 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26391	10041-20000-12865	1611 N NAUD ST	90012	1	136-5A217  49	5409002016	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.06819	-118.22779	OUTDOOR LIGHTING. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26392	16041-10000-33131	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.07594	-118.35916	T-24, PC FOR ENERGY ONLY. INTERIOR REMODEL OF EXISITING CAFETERIA. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1245 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26393	16041-10000-40695	5805 S CAMPUS CENTER DR	90094	11	102B161  1290	4211010109	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Closed	05/24/2018 12:00:00 AM	ADDRESS	33.97873	-118.40767	PC FOR MV CABLE. ONE CABLE SWAP OUT FOR TEMP WIRING. CHECKING PULL TENSION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26394	14041-10000-06966	11024 W MAGNOLIA BLVD SUITE A&B	91601	2	171B173   669	2353006025	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.16475	-118.37147	"PLANCHECK FOR T24 ENERGY. EXISTING RESTAURANT. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. SUITE ""A"" & ""B"" 1735 SQFT, EMERGENCY LIGHTING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26395	19041-10000-29019	19718 W SHERMAN WAY	91306	3	183B117    71	2135016020	C4-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	04/30/2020 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.20087	-118.56286	FULL PLAN CHECK FOR POWER AND ENERGY FOR GROCERY STORE. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON NEW 800 A DISTRIBUTION SYSTEM. TOTAL EFFECTED AREA 21,173 SQFT NEW CONNECTED LOAD OVER 400AMPS.LD# 19016-10000-23108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26396	14041-20000-25030	11516 N BALBOA BLVD	91344	12	213B133   620	2610004007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.27988	-118.50191	INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(20) SUN POWER SPR-327 MODULES(1) AURORA PVI-6000 TRANSFORMERLESS INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26397	16041-10000-39211	1035 S CRESCENT HEIGHTS BLVD	90035	5	132B173   562	5087013022	R2-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM			Corrections Issued	11/04/2016 12:00:00 AM	ADDRESS	34.05783	-118.36993	PV, INSTALLATION OF NEW 7.50 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO FAMILY HOUSE.(22) MODULES: SUNPOWER SPR-X21-345(1) INVERTER: SB7000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26398	14041-20000-33960	18026 W RODARTE WAY	91316	5	165B125   242	2184033015	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Expired	01/02/2017 12:00:00 AM	PIN	34.14808234	-118.52586278	pv1central string inverter standard plan system size 9.0kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26399	15041-20000-10050	12460 W OSPREY LANE unit# 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	Plan check for PV roof mounted system for tri-plex unit #3 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10046	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26400	11041-10002-04479	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM			PC Approved	10/18/2011 12:00:00 AM	ADDRESS	33.95887	-118.41869	REVISED SINGLE LINE DIAGRAM TO SHOW CHANGES IN THE TYPE OF FIRE PUMP FEEDER BEING USED AND USING FUSES INSTEAD OF A CIRCUIT BREAKER  AT THE POINT OF CONNECTION. ((((((((((INSTALLATION OF EMERGENCY GENERATOR; FIRE PUMP AND FIRE PUMP CONTROLLER WITH ASSOCIATED TRANSFER SWITCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26401	18041-10000-45884	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	02/24/2021 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLAN CHECK FOR TITLE 24 INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26402	15041-20000-39933	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.23953	-118.37198	Full PC for new warehouse shell only, Scope includes New Xformer, elec.room, house panels and site lighting.2000 MSA, total area: 255,181sq.ft (uncondition+hardscape)((WHSE SHELL))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26403	17041-20000-11656	13340 W SATICOY ST	91605	2	186B157   195	2303024031	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			Reviewed by Supervisor	04/21/2017 12:00:00 AM	ADDRESS	34.20828	-118.42362	New 1600A 120/208V 3ph-4w service for (2) new single-story commercial core and shell buildings.  Separate permit to be issued for each building at time of issuance.  Plan check for power and energy.  Building permits filed under 17010-20000-01318 and 17010-20000-01317	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26404	17041-10000-04498	1002 W E ST BLDG 8	90744	15	030B201   836	7417012924	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM				Plan check for new fire alarm system for appartment building. Total fire alarm devices: 34 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26405	15041-10000-16725	1206 N LAKME AVE	90744	15	033B209   369	7422018013	R1-1XL-O-HPOZ	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	33.78711	-118.25973	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(19) KYOCERA 260 MODULESD(1) ABB PV1 4.2 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26406	13041-10000-34013	7622 W MELROSE AVE	90036	5	141B177   644	5526015026	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	PIN	34.08343259	-118.35602483	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 910 SQ FT. REPLACING TOTAL OF 3 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26407	16041-20000-30063	3329 W SUNSET BLVD	90026	13	144A203   356	5426006008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.08729	-118.27551	Plan check for energy only. Change of use/TI to/for massage parlor. New lighting (incl. emergency). 4,256sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26408	11041-10002-02958	5550 W WILSHIRE BLVD #  101C	90036	4	132B181  1299	5089005***	[Q]C2-1-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.06206	-118.34979	"MODIFICATION TO APPROVED SET OF PLANS.  WILL USE EXISTING TRANSFORMER AND PANEL ""A"" INSTEAD OF INSTALLING TWO NEW TRANSFORMERS AND PANELS.  <<<<<<RESTAURANT AS FIRST TIME TENANT IN NEW BUILDING>>>>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26409	15041-10000-01123	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check T-24 only for T.I. total area: 893 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26410	19041-20000-14219	20627 W GREEN ASH LANE	91306	3	192B109   970	2108037001		South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.21971	-118.58296	Outdoor lighting in small lot sub-division. Plan check for energy only. Total outdoor area: 147,166 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26411	13041-10000-26322	18471-18477 W VENTURA BLVD	91356	3	171B125    25	2160008001	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.16876	-118.53553	new wiring for fire damaged single story  building;plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26412	16041-10000-14513	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			PC Info Complete	04/26/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	"TENANT IMPROVEMENT TO AN (E) COMMERCIAL SPACE FOR  FOOD AND BEVERAGE CONCESSION ""TORN BASIL"".  PANELS AND CIRCUITS ARE EXISTING, PC FOR T-24 ONLY, 33S SQ. FT.B# 16016-10000-09259"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26413	13041-10000-20652	8711 S METTLER ST	90003	9	096A207    14	6041018017	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	33.95882	-118.26672	TENANT IMPROVEMENT. UPGRADE SERVICE FROM 200AMP TO 800 AMP. ADDING CIRCUITS. NO CHANGES IN LIGHTING. POWER PLAN CHECK ONLY. 1 FLOOR. SERVER ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26414	18041-10000-01502	7458 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.20653	-118.49419	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 44200 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26415	14041-20000-05271	11361 N RUGGIERO AVE	91342	7	210B173    22	2529020004	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.27629	-118.36698	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26416	18041-20000-43767	5555 W MELROSE AVE Bldg 205	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Distribution replacement for movie studio.  Medium voltage equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26417	14041-20000-01967	1424 N AVENUE 46	90041	1	156A221   206	5474027026	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			Reviewed by Supervisor	02/07/2014 12:00:00 AM	ADDRESS	34.12152	-118.21634	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26418	11041-10000-06416	573 S BOYLE AVE	90033	14	126A221     2	5174001015	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.04034	-118.21997	REPLACING AN EXISTING DEFECTIVE FIRE ALARM PANEL AND ANNOUNCIATOR PANEL.    ALL THE DEVICES ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26419	14041-20000-16469	18333 W RANCHO ST	91356	3	168B125   527	2184058003	A1-1XL	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.15442	-118.53257	PV1.  Install 12 kW roof-mounted, utility-interactive PV system.  2 inverter system.$0 permit fee is due to Senate Bill SB-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26420	11041-10000-06345	400 S HOPE ST	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	T.I.  CORRIDOR IMPROVEMENT FOR 8TH FLOOR.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26421	16041-10000-01629	707 W MAC ARTHUR AVE	90731	15	021B197   748	7448005013	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	33.75069	-118.29271	PV1, ROOF MOUNTED SOLAR SYSTEM. (10) MODULES AND (1) INVERTER-3.0KW.  TOTAL SIZE IS 3.0KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26422	14041-20000-17619	1888 S CENTURY PARK EAST 14th floor	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.06104	-118.41402	T.I. NON BEARING NEW PARTITIONS & REFLECTED CEILNG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26423	18041-10000-47223	10949 N ZELZAH AVE	91344	12	210B129   639	2715021060	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.26953	-118.52364	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26424	13041-10000-26320	8386 N SAUSALITO AVE	91304	12	192B101   437	2004009017	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.22225	-118.61567	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON STANDARD PLAN WITH POWER OPTIMIZERS(OP250-LV).; SYSTEM SIZE IS 7KW DC WITH (28) MODULES: HANWHA #HSL60P6-PB-4-250QW(1) SOLAREDGE #SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26425	13041-10002-34279			3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	PIN	34.1851785	-118.60468145	down sizing the AL service laterals to the Costco Store from 1000KCMIL TO 750 KCMIL. CHANGES WERE MADE AS OFFICIAL LOAD AMOUNT WAS SUBMITTED AFTER CALCULATIONS WERE MADE USING AN ANTICIPATED LOAD. RHO FACTOR AND TEMPERATURE DERATING FOR THE DUCT INSTALLATION HAVE BEEN RECALCULATED.PLAN REVIEW FOR THE 35KV SERVICE AND ASSOCIATED DISTRIBUTION SYSTEM TO SUPPLY A NUMBER OF BUILDINGS TO BE CONSTRUCTED AS PART OF A NEW MALL.PLAN CHK WILL BE FOR THE 35KV LANDINGS TO THE OUTSIDE PERIMETER OF EACH BUILDING FOOTPRINT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26426	17041-20000-21436	21627 W ROSCOE BLVD	91304	3	192B105   585	2779036001	C2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM			PC Approved	06/26/2017 12:00:00 AM	ADDRESS	34.21991	-118.60123	new propane tank in hazardous location.  plan check for power only.permit fees paid under appliaction number 17041-90000-17366this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26427	11041-10000-05370	11766 W WILSHIRE BLVD 5TH & 16TH-FLOORS	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.04804	-118.46227	INTERIOR FINISHES UPGRADE EXISTING LOBBY & CORRIDOR & NEW CEILING CONSTRUCTION ON 5TH & 16TH FLOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26428	11041-20000-03561	255 S GRAND AVE	90012	9	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.05332	-118.25122	subway restaurant energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26429	17041-20001-43424	4345 S CRENSHAW BLVD	90008	8	111B185    46	5024006012	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	34.00419	-118.33292	1/30/2018changes to approved set of plans.  changes to reflect field conditions.  Changes noted delta A.This is plan check only.(((Plan check for power only. Upgrading service for existing commercial building to 800A 120/240V 3ph 4w. Existing loads to remain.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26430	19041-10000-26404	5965 S ST ANDREWS PL	90047	8	105B193   333	6001013906	M2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.98626	-118.3116	Plan check for a fire alarm system located on a single story commercial building. Scope includes (1) fire alarm panel and (41) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26431	18041-10000-13954	4303 N FIGUEROA ST	90065	1	145-5A223  20	5467005026	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1994.00	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.09472	-118.20866	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26432	11041-20000-19890	2025 N RODNEY DR	90027	4	150B197   393	5590006017	R3-1XL	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Apartment			09/19/2011 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.10844	-118.28927	New 23 unit apartment building.  Fire alarm will be subitted under a separate application.  A fire alarm variance was submitted on July 9, 2012.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26433	18041-20000-01682	1669-1673 N WESTERN AVE	90027	13	148-5A193 341	5544025033	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Issued	04/12/2018 12:00:00 AM	ADDRESS	34.10116	-118.30951	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT . CHANGE OF USE FROM MARKET TO FOOD PREP KITCHEN.BUILDING PERMIT #  16016-10000-19387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26434	19041-20001-06809	9400 S LA TIJERA BLVD	90045	11	096B161   831	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	33.95618	-118.4163	Expedited plan check fee.PV2.  Install 160.2 kW DC / 143.77 kW AC roof mounted grid tied PV system.  (445) modules with (4) 33.3 kW rated string inverters. System 1 of 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26435	18041-20000-14889	6150 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	temp power for construction site.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26436	14041-10000-28430	10149 W RIVERSIDE DR	91602	4	165B181    47	2424008020	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.15237	-118.35231	T24 ENERGY. REMODELING OF THE EXISTING RESTURANT. TOTAL AREA 2281 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26437	12041-10000-06614	16320 W BRYANT ST	91343	12	195B137   906	2689027015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.22742	-118.48824	New rooftop, 5.76kw photovoltaic rooftop system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26438	11041-20000-03316	16023 W VANOWEN ST 1-10	91406	6	183B141   768	2224028029	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.01	Electrical	Electrical	Apartment			02/22/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	34.19409	-118.48217	Plan check power and energy for new apartment building with 800A service.Note: Per engineer, do not issue permit unless RTI sheet is provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26439	18041-10000-10045	2110 W SUNSET BLVD SUITE N	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.07735	-118.26408	FIRST TENANT -RESTAURANT - IN COMMERCIAL SPACEFULL PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26440	15041-20001-15400	15489 W DUOMO VIA	90077	5	156B145   177	4378036002	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM			PC Approved	07/22/2015 12:00:00 AM	ADDRESS	34.124	-118.47064	Expedited per customer request.PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service panel.(37) Sunmodule SW 280 panel(37) Solar Edge P300 power optimizers(1) Solar Edge SE 1000A inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26441	17041-10000-44249	10773 W ASHTON AVE	90024	5	132B153   319	4325004013	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			12/08/2017 12:00:00 AM			PC Info Complete	10/23/2018 12:00:00 AM	ADDRESS	34.0592	-118.43836	PC FOR METHANE MITIGATION SYSTEM FOR A 5 UNIT MULTI-FAMILY. TOTAL DEVICE COUNT 15  WITH ONE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26442	19041-20002-06630	4920 N VAN NUYS BLVD pv1	91403	4	169-5A151  47	2248007139	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	34.15995	-118.4485	SUPPLEMENTAL, PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. SCOPE OF WORK INCLUDES CHANGE TO ROOF PV LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26443	14041-10001-03182	130 E KETCH MALL	90292	11	102A147    68	4295002055	R1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/07/2014 12:00:00 AM	ADDRESS	33.97447	-118.45944	Expedited plan check per applicant request.  (((PV1.  Install 10.0 kW roof-mounted PV system, interconnect with main service panel.  40 modules: Rensola JC250M-24/Bb.  2 transformerless inverters: SolarEdge SE5000A-US and SE6000A-US.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26444	17041-10000-35600	12822 W STRATHERN ST	91605	2	189B161   421	2305037046	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.21567	-118.41369	PC FOR ROOFMOUNTED PV ON SFD. SYSTEM SIZE 10.05KW, SCOPE INCLUDES 29 AC MODULES AND LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26445	15041-20000-05337	12744 N SAN FERNANDO ROAD Bldg 3	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for Title 24 only for ware house. Total area: 150 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26446	14041-10000-19368	4272 N PERLITA AVE	90039	13	159B205   753	5594010017	(Q)RD2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.13125	-118.26821	PV1 4.59KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE5000A-US}]. [(18)modules: {kyocera # KD255GX-LFB3}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26447	17041-10000-24843	28158 S WESTERN AVE #16	90732	15	024B193   622	7442030207	P-1XL, [Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	33.76327	-118.31053	PC FOR Interior TI in existing restaurant for title -24 energy only. Scope includes new panels, lights, receptacles and equipment. Total affected area 1542sq.ft.B#17016-10000-20003	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26448	12041-10000-24070	11863 N HOYT LANE	91342	7	216B165   288	2531010***	(Q)RD6-1, A1-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.03	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.28632	-118.3932	New 5.1 kw roof mounted PV for a single family. (use enphase 215)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26449	14041-20000-11618	1125 N LE GRAY AVE	90042	14	156A229   181	5485020018	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.12262	-118.19232	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. [[[[M250]]]  SYSTEM SIZE: 7.2KW(24) LG 300 MODULES(24) ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26450	11041-10001-21210	10000 W PICO BLVD BLDG 5	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.05211	-118.40654	Plan check for Delta 4 revision. Changes consist of lighting, kitchen equipment loads, and review for methane mitigation. BLDG. NO. 5 (Snack bar section inc. outside lighting) OF POOL HOUSE AT HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDGS. NO. 1, 2, 3, & 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26451	10041-10000-03566	111 N HOPE ST	90012	9	133-5A211 168	5161003910	PF-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.05807	-118.24862	installation of  2 ea  400A camlock receptacles to supply power for the movie industry. installation includes feeders/ disconnect switches and 150 KVA transformers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26452	17041-20000-43135	6050 W CADILLAC AVE	90034	10	126B173  1006	5066001048	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM			Reviewed by Supervisor	12/04/2017 12:00:00 AM	ADDRESS	34.03776	-118.37635	PV2.  Install 43.5 kW DC roof mounted grid tied PV system.  (3) different interconnection points.  (144) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26453	11041-20000-18334	3415 S SEPULVEDA BLVD #540	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	12/01/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	"Plan check T24 Energy/emergency lighting for office TI #540.  ""COMPLY WITH DEPARTMENT ORDER effective date  11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26454	17041-20001-42643	10580 W STALLION RANCH ROAD	91040	7	204B177   253	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.25709	-118.36008	expeditepv1install roof mounted pv system sized 20kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26455	18041-10000-37421	7541 N WOODMAN PL	91405	2	186B157   216	2215003003	MR2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.03	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.20726	-118.42999	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26456	19041-20000-35468	3627 W JEFFERSON BLVD	90016	10	120B185   809	5050031057	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	05/03/2020 12:00:00 AM	ADDRESS	34.02571	-118.33607	Plan check for Title 24 Energy only in existing space Tenant improvement Total area: 3935 sq ft. B#19016-10000-11092	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26457	14041-20000-17671	226 S BERENDO ST	90004	13	135B197    58	5518029006	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.07003	-118.29399	Remodel of existing apartment building.  Replace general lighting indoor/outdoor in common areas.  No changes in lighting switches and controls.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26458	17041-10000-42425	6724 N TROOST AVE	91606	2	180B169   166	2320013008	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Apartment			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.19294	-118.38648	PC for new 3.8kW PV system for rooftop solar. Installing 9 modules with optimizers and one central inverter. System is connected to seperate existing 100A panel. Inspector to verify rating of existing 100A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26459	17041-20001-46406	10966 N BATON ROUGE AVE	91326	12	210B121   599	2718010036	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.26951	-118.55084	Revisions to approved set.  Change of OCP rating to essential back-up load panel and wiring detail change. (((PC FOR NEW ESS INSTALLATION IN SFD. SCOPE INCLUDES SINGLE TESLA POWER WALL 2 (AC TYPE) WITH ADDITIONAL SUBPANEL.RESIDENCE HAS EXISTING PV SYSTEM)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26460	13041-10000-22267	20009 W GYPSY LANE	91364	3	168B113   289	2175018010	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.15691	-118.56903	PLAN CHECK FOR ROOF MOUNTED 15.19KW SOLAR PHOTOVOLATIC SYSTEM WITH FRONIUS TYPE INVERTERS AND TRINA  PANELS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26461	14041-20000-31182	5587 E HUNTINGTON DR NORTH	90032	14	147A239   269	5309024018	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	34.09526	-118.15856	Plan check for energy only. Lighting only for a restaurant. 935sqft. Permit for power pulled at express under permit #14041-20000-30890.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26462	14041-10000-10436	12746 W JEFFERSON BLVD # 2150	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT STARBUCKS ON AN EXISTING SWITCHBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26463	19041-10000-20446	953 N SYCAMORE AVE 6th Flr	90038	4	144B181   671	5531015010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.08865	-118.34299	Full plan check for a 1st time tenant OFFICE  T.I. located on the 6TH FLOOR  of a high rise building. Scope includes new lighting, and equipment with a total lighting area of 19,610-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26464	19041-20000-05233	8614 N VAN NUYS BLVD unit b	91402	6	192B149    35	2638001039	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.2266	-118.44937	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26465	14041-20000-16457	6601 E CHURCH ST	90042	14	157-5A235  25	5716017014	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.12669	-118.17041	3.5KW roof-mounted PV1 system with (14) Renesola 250w solar  modules, Solaredge Power optimizers and (1) Solaredge SE3800A-US inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26466	14041-20000-09809	338 S RENNIE AVE 2	90291	11	111B141   921	5018023056	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	33.99791	-118.47188	PV1.  Install 2.12 kW DC roof-mounted PV system, interconnect with main service panel.  (8) modules.  Microinverter standard plan - Enphase M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26467	11041-10000-00425	1925 S CENTURY PARK EAST # 1150	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	34.06066	-118.41426	Tenant improvement in existing offices.  Plan check is for Title 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26468	16041-10000-07262	3947 S OLMSTED AVE	90008	10	117B185  1221	5033021016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.01336	-118.32821	PV1 SFD TOTAL SYSTEM SIZE 3.6KW AC USING MICROINVERTER SYSTEM. USING ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26469	14041-20002-06426	4108 S DEL REY AVE	90292	11	108B153  1200	4230005040	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	33.98836	-118.4448	(($0 plan check fee due to senate bill 1222 from 2012)))changes to approved set of plans. change in 3 inverters to 9kw type. changes in wire size to accomadate new ampacity. change in voltage class to 208.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26470	16041-10000-24910	10375 W WILSHIRE BLVD 1ST FLR	90024	5	135B157   110	4359016187	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.06759	-118.42808	Plan check for Title 24 for 12637 sqft. Plan check for new lights and 3 new HVAC branch circuits.**REMODEL  (E) ENTRY WAY INTO LOBBY AT 1ST FLOOR. REMOVE AND REPLACE DOORS AND WINDOWS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26471	11041-10000-13746	4770 E VALLEY BLVD	90032	14	135A233    91	5223001023	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Expired	01/22/2014 12:00:00 AM	ADDRESS	34.06482	-118.18059	ADDITION (TO AN EXISTING INDUSTRIAL BUILDING) OF APPROXIMATELY 2,700 SQ FT OF INTERIOR OFFICES, RESTROOMS, AND WORKSPACE /STORAGE; STRUCTURAL ADDITION OF THREE EXTERIOR WINDOWS; STRUCTURAL ADDITION OF EXTERIOR CANOPY NE CORNER OF BLDG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26472	18041-10000-06193	8813 S SEPULVEDA BLVD	90045	11	096B165   974	4122035029	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			PC Info Complete	02/20/2018 12:00:00 AM	ADDRESS	33.9568	-118.39645	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING LIGHTING FIXTURES FOR A FINANCIAL TRANSACTION SPACE. TOTAL AFFECTED AREA IS 5030 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26473	16041-20001-21399	19500 W PLUMMER ST SUITE E	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Issued	05/15/2017 12:00:00 AM	ADDRESS	34.2426	-118.55846	"Revisions to approved set of drawings - revisions made to represent (E) conditions on site regarding electrical distribution as well as associated required design changes.  (((ADDING NEW 600 AMP DISTRIBUTION BOARD ""MDPC"" TO EXISTING BOARD MDP.  PLAN CHECK FOR POWER, SHELL ONLY.  SEE NOTES:BUILDING APPLICATION # 16016-20000-11934DEMO INT. OF (E) 2-STORY RETAIL SPACE INTO (2) RETAIL SHELL SPACES AT EACH STORY.  ADD ADDITIONAL FLOOR AREA BY INFILLING (E)ESCALATOR OPENING.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26474	11041-10000-16855	19700 S VERMONT AVE Ste 215	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM			PC Approved	08/10/2011 12:00:00 AM	ADDRESS	33.85221	-118.2903	T.I.  Suite number 215 lighting remodel.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26475	15041-10001-32066	15509 W VINCENNES ST	91343	7	198B145    87	2656015015	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.24106	-118.47005	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(15) REC SOLAR MODULES(15) POWER OPTIMIZERS (1) SOLAREDGE INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26476	16041-20003-45393	10046 N SAMOA AVE	91042	7	202-5A199  24	2568006050	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			04/02/2018 12:00:00 AM			PC Approved	04/02/2018 12:00:00 AM	ADDRESS	34.25157	-118.28721	Revisions to approved set of plans.  Combiner box/RSD locations revised, inverter output circuit wire size detail changed.  Plan check only.  Delta-4 revisions only.  (((11/14/17changes to an approved set of plans.  plans noted delta 1 and 2.  changes include updated plans to reflect field conditions.  this is plan check only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26477	14041-20000-28745	7012 N OWENSMOUTH AVE	91303	3	183B105   617	2138008010	P-1VL-RIO, [Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Closed	08/01/2018 12:00:00 AM	ADDRESS	34.19776	-118.60139	PV2 COMMERCIAL ROOFTOP SOLAR. USING ENPHASE MICROINVERTER MODEL 215. TOTAL SIZE 10.75KW AC UISNG 50 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26478	19041-10000-49622	1608 E COLON ST	90744	15	036B213   349	7426032054	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	33.79172	-118.2433	ENERGY PLAN CHECK FOR TITLE 24 ONLY. SCOPE OF WORK INCLUDES NEW 120/240V, 200A, 1PH SERVICE, NEW LIGHTING AND CIRCUITS. TOTAL SQAURE FOOTAGE IS 20,212.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26479	14041-10001-17824	8826 S CENTRAL AVE	90002	9	096A209   212	6043004018	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	33.9567	-118.25617	8/30/16 Changes to approved set 16041-10000-17824. Changes are clouded with delta 2. Changes to T24, change of location of service equipment and  new led lighting.**PC FOR POWER AND ENERGY.NEW 1-story 5,000 SQ.FT. COIN LAUNDRY BUILDING.BUILDING APPLICATION #:	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26480	18041-10000-01306	17331 W TRAMONTO DR	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Issued	04/09/2018 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 8 (CAMPUS STYLE)SCOPE INCLUDES 49 DEVICES AND 1 PANEL. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE B# 15010-10000-03645BUILDING 8 (PLAN B2)  2 UNITS  AND 2 STORY TYPE IIA  APARTMENT BUILDING WITH   ATTACHED TYPE IB GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26481	17041-10000-16176	720 E 2ND ST	90012	14	129A215   211	5163007013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.04706	-118.23533	T24 ONLY, REPLACE (E) LIGHT FIXTUES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  14925 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26482	19041-10000-05755	13200 W BURBANK BLVD	91401	4	174B157   655	2345005900	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.17197	-118.42063	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26483	15041-10001-00464	707 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.78001	-118.24199	"Supplemental application for expedite feesInstallation of new roof mounted solar PV array on existing locomotive repair facility.  20 strings with 14 modules per string connected to one 100 kWac ""Power Gate Plus"" inverter (480 Vac)."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26484	11041-10000-16681	3880 N MISSION ROAD 2nd floor	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	01/30/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	T.I.  First time tenant to occupy all three floors of a 3-story building.  Application reflects the third floor occupancy only.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26485	19041-20000-44392	11900 W OLYMPIC BLVD ste 720	90064	11	123B149   541	4259024003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.03252	-118.45186	ENERGY ONLY PLAN CHECK FOR TITLE 24. REPLACING LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2217 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26486	17041-30000-05236	2601 S FIGUEROA ST 2nd Floor	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.02804	-118.2763	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 14,645 sq. ft.Note: Building application has been generated under 16016-10000-30289	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26487	14041-20000-05254	20750 W VENTURA BLVD SUITE 310	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.16638	-118.58506	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON SUITE 310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26488	15041-10000-09921	8527 N SEPULVEDA BLVD	91343	6	192B145   119	2654020015	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.22544	-118.46799	NEW FIRE ALARM SYSTEM FOR NEW MEDICAL CLINIC . 242 FA DEVICES, ONE CONTROL PANEL AND ONE ANNUNCIATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26489	16041-10001-32793	9901 N SUNLAND BLVD	91040	7	201B181    91	2543023018	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.2498	-118.34713	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.8KWac.(56)MODULES-REC275TP-REC SOLAR(1)INVERTER-(NINGBO TECH.)SOLIS-3.6K-2G-US(1)INVERTER-SOLIS-4.6K-2G-US(1)INVERTER-SOLIS-4.6K-2G-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26490	12041-10000-28837	12150 N BELLANDO CT	91344	12	219B125    93	2601074003	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.29503	-118.52543	7.92 kw roof mounted PV for a single family. (PV1)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26491	16041-20001-19112	18130 W CALVERT ST	91335	3	177B125   557	2124015031	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.18173	-118.52812	EXPEDITE PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 14KW INTERCONNECTED WITH MSP.(48) LG MODULES(2) SMA 7000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26492	19041-10000-20049	6814 S AVALON BLVD	90003	9	102B205   234	6007019019	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	07/07/2020 12:00:00 AM		Permit Finaled	09/23/2020 12:00:00 AM	ADDRESS	33.97753	-118.26497	PLAN CHECK FOR T-24 ONLY. SCOPE OF WORK INCLUDES INSTALLATION OF NEW EQUIPMENT, LIGHTING, AND CIRCUITS.TOTAL AFFECTED AREA: 11,148 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26493	18041-20000-07297	9561 W SAWYER ST	90035	5	129B165   969	4309011019	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.04582	-118.39706	PLAN CHECK FOR BATTERY BACK UP SYSTEM TO AN EXISTING ROOF MOUNTED PV SYSTEM - (2) NEW TESLA POWER WALL(14KWH) WITH EXISTING 22.8KVA PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26494	13041-10000-28638	380 WORLD WAY T24-NG	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	sign lighting. 2 signs for EconomistFIRST TIME TENANT AT TOM BRADLEY INTERNATIONAL AIRPORT. EXPRESS PERMIT WAS PULLED UNDER APPLICATION NUMBER 13041-10000-09503. TI- BRANCH CIRCUIT & LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26495	14041-10014-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	PIN	34.0586034	-118.41904766	Change to approved set by modifing the drawing on the single line diagram. All load remains the same. No load being added nor removed. All changes under delta_36 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26496	17041-20001-19739	7932 W BEVERLY BLVD	90048	5	138B177   459	5511001019	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.07588	-118.36244	08/15/2017 Plan check for Title 24 only. Project site is an existing commercial retail space. Project scope is a tenant improvement. Total lighting area = 1,340 sq. ft.*****Preivous Work Description*****20 outlets , 40 4' LED lights ,Replace some plywood in existing mezzanine	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26497	19041-20000-05049	11055 N HASKELL AVE	91344	12	210B141  1089	2667014***	(Q)RD6-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	PIN	34.27150717	-118.47668338	PV1.  Install 6.120 kW roof mounted grid tied PV system.  (17) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26498	19041-20000-12684	2417 E WHITTIER BLVD	90023	14	124-5A221 288	5185028027	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM			Reviewed by Supervisor	05/10/2019 12:00:00 AM	ADDRESS	34.03426	-118.21502	existing (2) story commercial building new 800 amp service.  converting second floor only to (6) unit residential.  plan check for power and energy.building application number 19016-10000-07116	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26499	16041-10000-14470	2029 S CENTURY PARK EAST Suite 700	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING FOR SUITE 700. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 8655 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26500	13041-20001-07409	777 S FIGUEROA ST 1500	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.04828	-118.26116	Addition to approved set of plans.Change to lighting in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26501	14041-10001-13823	607 N ARDMORE AVE	90004	13	141B193   872	5521007012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			Reviewed by Supervisor	06/13/2014 12:00:00 AM	ADDRESS	34.08196	-118.30186	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26502	19041-20000-22684	5670 W WILSHIRE BLVD ste 1790	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26503	19041-10000-33082	8551 W VENICE BLVD	90034	10	123B173   324	5065011040	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Info Complete	09/10/2019 12:00:00 AM	ADDRESS	34.03503	-118.37883	T-24 PLAN CHECK FOR A TI TO A CAR RENTAL OFFICE. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 4550 SQ.FTB#18016-20000-22129	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26504	12041-10000-04238	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	34.07417	-118.26931	Plan check remove and replace existing fire alarm devices and install new  power supplies for existing high rise building on 8th, 9th, 12th, 14th, and 15th floors	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26505	17041-20000-28529	2226 S OVERLAND AVE	90064	5	126B157    48	4320007027	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	02/10/2018 12:00:00 AM	ADDRESS	34.04529	-118.42738	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 7.6 kWac and consists of (1) inverter, (20) modules, (1) load center, and (1) DC battery unit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26506	18041-10000-31265	5026 S AVALON BLVD	90011	9	111A207   262	5108012030	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2292.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.99677	-118.26503	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26507	18041-30000-22817	340 S MAIN ST	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Info Complete	06/20/2018 12:00:00 AM	ADDRESS	33.99519	-118.47673	Plan check for T24 only, TO to (E) breakroom area in (E) office space. Total area: 628 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26508	18041-10000-03053	652 E MANCHESTER AVE	90001	9	097-5A207 311	6042001034	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	33.95998	-118.26324	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. PLAN CHECK T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26509	10041-10000-13041	533 S LOS ANGELES ST	90013	14	127-5A211  22	5148020001	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM			PC Info Complete	12/07/2010 12:00:00 AM	ADDRESS	34.04536	-118.24846	up-grade of retrofit  of seven floors over subterrean basement ; core and shell only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26510	15041-10000-39611	630 W 65TH ST	90044	8	105B201  1450	6013016010	R2-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.98046	-118.28433	PV1, ROOF MOUNTED SOLAR SYSTEM. (9) MODULES, SUN EDISON,  AND (9) ENPHASE ENERGY MICROINVERTERS. TOTAL SIZE 1.9KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26511	10041-10000-25348	2943 S CLUB DR	90064	5	126B165  1097	4316028001	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2010 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	ADDRESS	34.03731	-118.40069	NEW 10.8KW PV SYSTEM ON A ROOF OF A SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26512	11041-20000-18978	5757 W WILSHIRE BLVD #360	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.06259	-118.35341	PLAN CHECK POWER AND ENERGY FOR NEW DENTIST OFFICE #360 IN HIGH RISE BUILDING. NEW PANEL, BRANCH CKTS, AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26513	15041-10000-41291	2249 N TALMADGE ST	90027	4	150B201   206	5591005010	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.11043	-118.28177	PV1 3.0KW roof-mounted system with (13) Trina Solar TSM-255 modules and (1) ABB PVI-3.0-OUTD inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26514	18041-10000-45084	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.12626	-118.21412	PLAN CHECK FOR FIRE ALARM SYSTEM WITH 1 FIRE ALARM PANEL AND 70 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26515	12041-10000-12013	16959 W DEVONSHIRE ST	91344	12	204B133   181	2684012045	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.25768	-118.50176	NEW 1-STORY 2,158 S.F. RESTAURANT W/ 21 PARKING SPACES. Plan check for energy and emergency lighting. Less than 100 occupants, less than 400 amps installed load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26516	18041-20001-16736	7128 N VAN NUYS BLVD	91405	6	183B149   808	2217007040	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.20002	-118.44856	Revisions to approved set of plans.  Changes to lighting system - hood light additions.  (((Interior tenant improvement of (E) retail space into restaurant.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26517	15041-10000-28888	652 N LA BREA AVE	90036	5	141B181   668	5525017011	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Public Safety Only			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.08313	-118.34386	NEW FIRE ALARM PANEL AND ADDITION OF 17 DEVICES. PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-10000-20920.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26518	14041-10003-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/03/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Expired	12/11/2017 12:00:00 AM	ADDRESS	34.0504	-118.26023	"DELTA 3 CHANGES TO PERMITTED SET OF PLANS: NEWPANELS WERE ADDED; INCREASED  SIZE OF MV FEEDER TO 4/0 FROM 3/0; CHANGED SIZES FOR SEF; AHU;MAU;PCU;CRAG UNITS ALL CHANGES ARE CLOUDED AND IDENTIFIED WITH ""DELTA  3"" MARKINGS"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26519	13041-10000-27276	6222 N KESTER AVE 1-22	91411	6	178-5A149 166	2241016012	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.18315	-118.4573	FA FOR 22 UNIT APT 3 STORY OVER BASEMENT. 1 facp, 1 ann, 1 remote power supply. 95 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26520	16041-10000-30652	3201 S HOOVER ST 8-C3	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Info Complete	09/20/2016 12:00:00 AM	ADDRESS	34.02548	-118.28442	T-24, PC FOR ENERGY ONLY. TI FOR A RETAIL SPACE ON THE GROUND FLOOR FOR SUITE 8-C3. SCOPE INLCUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2038 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26521	15041-10000-34316	5630 N FIGUEROA ST	90042	1	151-5A229 295	5468032017	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.10933	-118.19295	PC FOR ENERGY. T.I. FOR  A RESTURANT. TOTAL 1395 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26522	16041-10000-12997	508 W BERNARD ST	90012	1	136-5A215 154	5414006029	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.06723	-118.23769	T-24, pc for Energy only for an existing commecial building (Nest Studios). Scope includes new lighting, receptales, two new panels for living room, lounge, bathroom, and storage areas (Phase 2). Total area is 1937 sq. ft. Note: Phase 1 of project is under PCIS#15041-10000-42782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26523	14041-10001-29653	211 S LA BREA AVE	90036	5	138B181  1307	5513022012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.07066	-118.34433	ORIGINAL SET OF PLANS FOR ENERGY CALS ONLY, LOST.  THIS APPLICATION IS PLAN CHECK FOR ENERGY ONLY.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-29653Plan check for energy only. New building, furniture retail space. Check lighting design to meet 2008 CA Energy Code standards (building permit submittal pre-July 1st, 2014). Indoor: 2,377sqft. Outdoor: 2,495sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26524	13041-20000-03843	1050 S FREDERICK ST	90291	11	111B145  1707	4243003053	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			02/13/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Issued	03/13/2013 12:00:00 AM	ADDRESS	33.99927	-118.46029	Plan check for new fire alarm system. Please reverify fees during final fee period.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26525	19041-20000-39176	15712 W DRELL ST	91342	7	222B141   268	2604014043	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.30231	-118.47296	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. 11.8 KW DC/7.8 KW AC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26526	19041-10000-53566	13230 W SATICOY ST	91605	2	186B157   209	2303028002	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	01/25/2021 12:00:00 AM	ADDRESS	34.20783	-118.42137	PC FOR T-24 ENERGY ONLY. TOTAL AFFECTED AREA 24698sqft. SCOPE OF WORK INCLUDES REMODELLING OF AN EXISTING SPACE BY INSTALLING NEW LIGHTS, USING EXISTING PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26527	12041-10004-29254	380 WORLD WAY Suite-6C4-10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	MODIFICATION TO APPROVED SET OF PLANSTHE FIRST TENANT LOUNGE TO BE BUILT IN CORE AND SHELL OF LAX. TOM BRADLEY INTERNATIONAL AIRPORT. CHANGES ARE CLOUDED.************************************************************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26528	13041-10000-36313	627 N GRAMERCY PL	90004	4	141B193   749	5522007007	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.08254	-118.31275	PV1, Install 3.25 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (15) Modules: Trina Solar TSM-250PA05.18.(15) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26529	13041-10000-02694	662 N SEPULVEDA BLVD	90049	5	138B145    76	4368016068	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.07736	-118.4688	TI OF OFFICE SPACE. RECONSTRUCTION OF OPEN SPACE TO SMALLER OFFICES. PC FOR T24 ONLY. TOTAL AREA OF 1132 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26530	12041-20000-30215	3717 S GRAND AVE	90007	9	117A203    47	5122025006	[Q]C2-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM			PC Approved	02/08/2013 12:00:00 AM	ADDRESS	34.01615	-118.27889	energy plan check USC office space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26531	16041-10000-18344	8855 N WAKEFIELD AVE	91402	6	195B149   295	2639005016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.23154	-118.4475	PV1, rooftop solar installation.  3.75KW AC system.  (15) SW275 MONO     (15) M250-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26532	15041-10000-10875	8500 S VERMONT AVE BLDG B	90044	8	097-5A199 185	6032013905	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	33.96105	-118.29134	"NEW DEVELOPMENT 1600 AMP SERVICE, CORE AND SHELL,  PC FOR POWER AND ENERGY. THIS IS BULDING 'B' OF 7 BUILDINGS. TITLE 24 ENERGY CALCS FOR COMMON AREAS TO BE SUBMITTED AT A LATER TIME. ENERGY FEES ARE ESTIMATED BY BUILDING LOAD CALCULATIONS. (((PROPOSED  3-STORY RETAIL AND RESTAURANT BUILDING.THIS BUILDING IS KNOWN AS BLDG ""A""  TYPE VA W/ SPRINKLER SUBSTITUTION FOR FIRE RESISTANCE RATING. )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26533	13041-10000-35883	200 S MAIN ST	90012	14	130-5A213 115	5161026023	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM			Verifications in Progress	04/28/2014 12:00:00 AM	ADDRESS	34.05073	-118.24453	PLAN CHECK FOR FIRE ALARM. INSTALL  AUTOMATIC MANUAL FIRE ALARM SYSTEMS FOR CITY HALL  EAST. 18 STORIES WITH MEZZANINE PLUS 4 PARKING STORIES. HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26534	17041-20000-17635	6333 W 3RD ST #416	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.07157	-118.36014	TENANT IMPROVEMENT EXISTING TAKE-OUT RESTAURANT (ICE CREAM SHOP).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26535	13041-10001-32190	68 S FREMONT PL	90005	4	132B185   344	5090020013	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	34.05886	-118.32703	Expedited RSES plan check per applicant request.(((PV1, Installing 17.004 KW DC roof mounted solar array on a  single family house, inverter:Sun Powr SPR-7501f-1 UNI. 52 module: SunPower SPR-327NE-WHT-D.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26536	15041-20000-14449	10177 N WEALTHA AVE	91352	7	204B173   186	2528016017	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.25523	-118.37697	installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26537	11041-10000-15637	1231 S WEST BLVD	90019	10	129B185   510	5083013035	R3-1	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Public Safety Only			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.05085	-118.33305	REPLACING FIRE ALARM PANEL COMPATIBLE WITH EXISTING FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26538	10041-10000-01305	12050 W VENTURA BLVD A202	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Public Safety Only			01/25/2010 12:00:00 AM	01/25/2010 12:00:00 AM		Permit Finaled	02/03/2010 12:00:00 AM	ADDRESS	34.14349	-118.39426	New FACP to monitor ANSUL for a restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26539	17041-30000-30231	10635 W WILSHIRE BLVD 1-46	90024	5	132B153    69	4360011003	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Closed	05/27/2020 12:00:00 AM	ADDRESS	34.06138	-118.43484	Plan check for new Fire alarm system in existing building 5 story 24 units appartment. Total Devices: 64 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26540	17041-20000-39616	10465 W ARMINTA ST	91352	2	189B177   368	2407016028	M1-1, MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.21419	-118.35948	ti to an existing warehouse.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26541	19041-20000-08770	6701 S CENTER DR WEST 5th flr	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26542	15041-30000-43247	800 W WILSHIRE BLVD 3RD FLR	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.0493	-118.25841	Title 24 plan check only.  Total area = 12,430 sq. ft.  Office T.I. to 3rd floor of existing commercial highrise.  New lighting, receptacles, & HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26543	15041-20000-27782	4931 N WAWONA ST	90041	14	162A219   243	5683034027	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.13772	-118.22576	Plan check for a PV1 roof-mounted PV system. System size is 0.86 kWac and consists of (4) modules and (4) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26544	13041-20001-22819	3966 S KEESHEN DR PV-1	90066	11	111B157   306	4235028016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	ADDRESS	34.00251	-118.42697	EXPEDITEPV-1. Power optimizers. 3kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26545	16041-10000-37668	505 S VIRGIL AVE UNIT # 205	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.0649	-118.28724	TENANT IMPROVEMENT OF (E) MEDICAL OFFICE (NO CHANGE OF USE) pc for power and energy	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26546	16041-20001-29954	415 E MANITOBA ST	90293	11	093B153   117	4117030017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	33.95337	-118.44194	EXPEDITED PER APPLICANTS REQUESTBATTERY STORAGE SYSTEM. SYSTEM SIZE: 500 WATTS.  PV1. ROOFMOUNTED SOLAR SYSTEM. 2 SUNSPARK SMX-250P MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26547	16041-30001-00487	14031 W VICTORY BLVD 2-3	91401	2	180B153  1077	2238025005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			01/07/2016 12:00:00 AM			PC Approved	02/12/2016 12:00:00 AM	ADDRESS	34.18683	-118.43882	Expedite fees only.     Installation of new roof mounted PV array on existing apartment building.  System consists of two 3 kWAC inverters each with different interconnection points; one at apartment 2 load center and one at apartment 3 load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26548	18041-20001-05415	11110 N RUFFNER AVE	91344	12	210B137   408	2682019001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.27225	-118.49763	3/19/19changes to an approved set of plans.  changes to consolidate (2) ESS.this is plan check only.  ((((Plan check for power only. Project scope is the addition of (2) PowerWalls to an existing roof-mounted PV system.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26549	16041-20001-28646	223 W 8TH ST	90014	14	127-5A209 314	5144015***	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.04359	-118.25421	10/27/2016 Plan check for a lost set of approved electrical plans. Scope of work has not changed.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR MOD'S HAIR DTLA. HIGH RISE. 657 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26550	18041-10000-01071	660 S FIGUEROA ST STE 1980	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM			Corrections Issued	01/10/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR OFFICE TI IN A HIGH RISE FOR TITLE 24  ENERGY ONLY. SCOPE INCLUDES NEW PANEL, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 2035 SQ.FT. B#17016-10000-38375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26551	15041-20001-05368	10014 N WEALTHA AVE	91352	7	204B173   402	2538028014	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM			PC Approved	04/20/2015 12:00:00 AM	ADDRESS	34.25219	-118.3734	Change to approve set of plan; Add 30A combiner box and 30A disconnect((((((((PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200S MSP located on a detached garage.System size: 4kW. Ungrounded system. (16) 270W pv modules across two strings (8+8).))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26552	19041-10000-26294	10341 N JOVITA AVE	91311	12	204B113   106	2707015030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.25858	-118.57662	$0 FEE DUE TO AB1414---[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 11.3KWac/13.725KWdc SYSTEM CONSISTING OF 2 INVERTERS(SE7600H-US, AND SE3800H-US) WITH  45 MODULES USING P320 OPTIMIZERS CONNECTED TO NEW 225A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26553	15041-20000-11281	3912 N LAUREL CANYON BLVD 1-36	91604	2	162B165   455	2369019032	R4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.14145	-118.39429	Plan check for a PV2 roof-mounted PV system. System size is 22 kWac and consists of (90) modules, (2) inverters, (2) combiner boxes, and (1) 100-amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26554	14041-20000-03590	11508 N JENNY LANE	91344	12	213B129   269	2601040070	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.27983	-118.52014	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 4 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26555	16041-30001-39386	133 S BARRINGTON PL	90049	11	135B145   480	4402008011	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.06636	-118.46932	Plan check for Title 24 only in existing space for nail salon. Total area: 1,780 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26556	15041-20001-27522	7817 N LANKERSHIM BLVD	91605	6	189B169   659	2310025031	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	34.21268	-118.388	Expedite per applicant request[[[[[[Plan check for PV roof mounted system in commercial building. System size: 11.4kW with 44 modules]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26557	13041-20000-26714	23019 W MARIANO ST	91367	3	171B097    14	2042007004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.16844	-118.6284	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 30 MODULES. 3 STRINGS/ INVERTER. NONSTANDARD PLAN. TRANSFORMERLESS INVERTER. PC REQUIRED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26558	16041-10000-29029	580 S ALAMEDA ST	90013	14	126A215   317	5164009041	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	01/25/2017 12:00:00 AM		Issued	01/25/2017 12:00:00 AM	ADDRESS	34.03894	-118.23818	TITLE 24 FOR EXISTING COMMERCIAL BUILDING(TI TO EXISTING BUILDING).TOTAL SQ. FT. (2187)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26559	19041-10000-18247	12746 W JEFFERSON BLVD 3150-Grnd  Flr	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	Full plan check for a MEDICAL OFFICE Tenant improvement located on the ground floor of a 3-story building. Scope  INCLUDES NEW LIGHTING and equipmnt with a total lighting area of  1260-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26560	16041-20000-22639	22031 W PROVIDENCIA ST	91364	3	168B101   356	2170010009	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.15784	-118.60699	PV1.  Install 6 kW roof mounted PV system.  Central inverter standard plan.  (28) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26561	11041-10000-06402	7800 W WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			Verifications in Progress	07/28/2011 12:00:00 AM	PIN	33.93790872	-118.42837934	AIRCRAFT PARKING AND MAINTENANCE.   PROVING POWER FOR THE EQUIPMENT USED.  INSTALLING 10 NEW <200 AMP PANELS, 2 401-600 AMP PANELS, 1 OVER 1200 AMP PANEL.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26562	13041-10000-06223	635 W DOWNEY WAY	90089	8	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Closed	07/17/2014 12:00:00 AM	ADDRESS	34.01874	-118.28387	Temporary power for a new building on USC campus.  Greater than 400 A new load on existing campus switchboard.  Methane buffer zone - new feeders originate below grade.  New switchboard and tower crane being supplied by existing switchboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26563	19041-10000-35359	2913 W EXPOSITION PL Units 1	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02048	-118.32811	Plan check for a PV2 2.56kw DC / 3.0KW AC roofmounted system. Scope includes (8) modules and (1) inverter interconnecting through the service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26564	10041-10001-19348	12148 W HART ST	91605	2	183B165   274	2321009041	R3-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			12/13/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.19731	-118.39828	REVISED PERMITTED SET OF PLANS: DOORS FOR ELECTRICAL RRELOCATED SUCH THAT EGRESS IS INTO GARAGE; APARTMENT METER SECTION RELOCATED OUTSIDE  IN THE GARAGE WITH A FUSED DISCONNECT TO MEET THE TAP RULE; New 25 units appartment building. Plan check for power and energy. (Variance for separate fire alarm system has been field.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26565	16041-10000-03282	1264 W ADAMS BLVD	90007	9	123B197   891	5055014004	R4-1L-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			01/28/2016 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	05/12/2022 12:00:00 AM	ADDRESS	34.03252	-118.28812	Full PC, New four-story apartment building with 12 units. 600amp service and 1 typical panel.  Total sq. ft. 8941 indoor and 3590 outdoor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26566	19041-10000-19967	4201 W WILSHIRE BLVD 2ND FLR	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.06189	-118.31911	Energy plan check for an office T.I  loaceted in the 2nd floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 5125-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26567	10041-10000-06223	10830 W MASSACHUSETTS AVE	90024	5	129B153   228	4325022036	[Q]RD1.5-1	West Los Angeles	Westwood			2655.20	Electrical	Electrical	Apartment			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.05196	-118.43811	NEW FIRE ALARM SYSTEM FOR 4 STORY 5 UNITS APARTMENT BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26568	13041-10001-28867	9118 N REMICK AVE	91331	6	198B161   540	2629030029	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.23547	-118.40978	][][]EXPEDITED PER APPLICANT REQUEST [][][][PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A SINGLE STORY HOME. INTERCONNECTING WITH (N) 225A MAIN SERVICE PANEL. SYSTEM SIZE IS 3.75KW DC, & IS XFORMERLESS, WITH(15) MODULES: TRINA SOLAR #TSM-250PA05.18(1)INVERTER: POWER-ONE #AURORA PVI-3.6-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26569	14041-10000-05974	11330 W SANTA MONICA BLVD	90025	11	129B149   544	4261009033	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Issued	03/05/2014 12:00:00 AM	ADDRESS	34.04593	-118.44929	TWO STORY COMMERCIAL  FIRE ALARM. ONE PANEL AND 34 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26570	13041-10000-02011	5500 S VERMONT AVE	90037	9	108B197   820	5001009013	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	33.9922	-118.2913	Plan check power and energy existing commercial building. New 800A service and equipment for future retail spaces in building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26571	17041-10000-42224	2305 S PADUA PL	90291	11	108B149   840	4237009006	R3-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	33.99194	-118.45582	PC for a new AC Power Wall(5.8KVA / 13.5KWH) and one new 125A Subpanel for single family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26572	19041-10000-46303	6600 N TOPANGA CANYON BLVD #1000-1001	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT. SCOPE OF WORK INCLUDES NEW EQUIPMENT, NEW RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 2311 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26573	14041-10000-15845	8101 S VERMONT AVE	90044	8	099B197  1081	6033022002	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	33.96531	-118.29201	PC FOR POWER AND ENERGY. COMPLETE INTERIOR REMODEL OF AN EXISTING  TO  OFFICE. TOTAL AREA 7,964 S.F. OLTG FORMS ARE MISSING.BUILDING # 14016-10000-09501.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26574	14041-10000-24360	4605 N LANKERSHIM BLVD #700	91602	2	168B173   921	2421028013	C2-2	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM			Verifications in Progress	06/05/2015 12:00:00 AM	ADDRESS	34.15405	-118.36832	Plan check for energy only. T24. No change in occupancy. Tenant improvement of offices. high rise. 2829 sq. ft. Emergency lighting. Suite #700, 7th floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26575	17041-10000-37396	3966-3976 W MELROSE AVE	90029	13	142-5A201 288	5539026025	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.08347	-118.28631	FULL PC FOR POWER AND ENERGY FOR A NEW 24 UNITS MIXED USE RESIDENTIAL BUILDING WITH TWO LEVELS OF GARAGE AND ONE RETAIL SPACE. TOTAL AFFECTED AREA IS 22039 SQ. FT. B#16010-10000-04026	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26576	17041-20001-13879	5840 S LOS ANGELES ST	90003	9	108B205  1190	6006004054	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM			PC Approved	05/10/2017 12:00:00 AM	ADDRESS	33.98863	-118.27041	expeditepv2install roof mounted pv system sized 40kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26577	19041-10000-50035	8475 S VERMONT AVE	90044	8	097-5A199 166	6033025902	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/24/2021 12:00:00 AM	ADDRESS	33.96111	-118.292	Plan check for Fire Alarm system, system consist of (1) FACP, (2) Power supply and (78) Devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26578	13041-10000-08534	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			Not Ready to Issue	04/03/2013 12:00:00 AM	ADDRESS	33.94221	-118.40701	Title 24 plan check only for sign lighting in LAX terminal 4 space 4A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26579	18041-20000-17575	15938 W NORDHOFF ST	91343	12	198B141   702	2672005034	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.23538	-118.47978	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (2) inverters, (31) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26580	17041-10000-08482	810 E PICO BLVD 138	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.03119	-118.25079	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE(RETAIL). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1368 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26581	17041-10000-14466	11150 W OLYMPIC BLVD SUITE 620	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.03956	-118.43857	PC FOR TI, T24 ENERGY ONLY. OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26582	14041-10000-12296	7226 S FIGUEROA ST	90003	8	102B201  1042	6020029006	RD2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	33.97384	-118.28247	New fire alarm for a one story building. 121 devices and  one fire alarm panel. 6 zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26583	10041-20000-21880	241 N COPA DE ORO ROAD	90077	5	141B153   249	4362013013	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.07998	-118.43999	Plan check for 13.5KW Photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26584	16041-10000-00351	733 N HUDSON AVE	90038	4	141B185   418	5533036006	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.0844	-118.33219	NEW FIRE ALARM SYSTEM TO A NEW APARTMENT BUILDING. TOTAL FIRE ALARM DEVICES 117, 1 FIRE ALARM PANEL AND 2 POWER SUPPLIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26585	16041-20000-38637	11117 W SARAH ST	91602	4	168B173   948	2353035016	R1-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.15357	-118.37288	$0 permit fee due to State Senate Bill SB 1222Plan check for PV system roof-mounted on SFD. 15kW ungrounded system. (59) enphase M250. (59) 290 W PV modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26586	19041-10001-39388	1365 N SUMMITRIDGE DR	90210	5	147B157   508	4355007010	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	34.09536	-118.41989	Expedite per applicant request PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 40 MODULES (LG365Q1C-A5) AND 40 MICROINVERTERS (IQ7PLUS-72). SYSTEM SIZE IS 11.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26587	15041-20000-00773	749 S SAN JULIAN ST	90014	14	126A211   456	5145005019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	PIN	34.04006359	-118.24900872	$0 permit fee due to senate bill 1222 from 2012PV2 COMMERCIAL ROOFTOP SYSTEM. TOTAL SIZE 170KW AC USING MULTIPLE INVERTERS. SYSTEM IS NET METER. TOTAL OF 728 MODULES. PER APPLICANT NO OTHER PV SYSTEM ON THIS POI. INSPECTOR TO VERIFY TOTAL BACKFEED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26588	14041-20000-05159	22901 W VENTURA BLVD	91367	3	171B097   459	2042017009	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	PIN	34.16573888	-118.62526362	Install general lighting (indoor and outdoor) for additional space.  Plan check for energy only.Note: Permit is under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26589	13041-20000-14751	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.05886	-118.41642	T24 FOR HIGH RISE OFFICE SPACE. SCOPE OF WORK IN UNIT 1875. TOTAL SQRFT 2460.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26590	15041-10004-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	10/05/2016 Changes to an approved set of plans. Changes include revised circuit label to include room number on panel schedule, add new circuits, relocation of receptacles on floor plan. Changes has been clouded on Delta36 for Package # 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26591	14041-10000-10774	3615 E TACOMA AVE	90065	1	147A219    12	5454011027	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.09901	-118.22542	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26592	17041-10000-33790	4159-4163 S BUCKINGHAM ROAD BLDG A	90008	10	114B181    79	5032014003	R3-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			09/20/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	PIN	34.01110726	-118.34372444	PC FOR 600A SERVICE UPGRADE AND CHECKING SERVICE AND SUBPANELS. PERMIT FOR SERVICE ONLY. SUBS ISSUED UNDER SEPARATE PERMITS. THIS IS PERMIT 2/2NOTE: PERMIT FEES TO BE PAID UNDER INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26593	11041-10000-09697	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Apartment			05/12/2011 12:00:00 AM			PC Approved	05/19/2011 12:00:00 AM	PIN	34.12750533	-118.21285206	T.I FOR THE FIRST AND SECOND FLOOR BATHROOMS AT A DORMITORY BULIDING WITHIN OCCIDENTAL COLLEGE.  PLAN CHECK IF FOR TITLE 24 AND EMERGENCY LIGHTS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26594	13041-10000-30142	2944 N GLENEDEN ST restroom-BLDG	90039	13	150A211    31	5442031901	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.10723	-118.24816	PLAN CHECK AND PERMIT FOR new restrooms bldg  FOR MARSH PARK.PLAN CHK IS FOR TITLE 24. SCOPE OF WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26595	16041-20000-13594	5415 N SEPULVEDA BLVD	91411	4	172-5A145  20	2250001021	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			04/19/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.16888	-118.4664	Plan check for a PV2 roof-mounted PV system. System size is 17 kWac and consists of (3) inverters, (70) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26596	14041-10003-23521	2645 S LA CIENEGA AVE	90034	10	123B173   670	5065007006	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.0335	-118.3785	Expedite per customer requestPV2 43.095 KW roof-mounted system including 169 hanwha solar modules and one Fronius CL 33.3KW  inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26597	13041-20000-28095	21700 W OXNARD ST SUITE 345	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.17901	-118.60179	PC FOR T24 ENERGY ONLY. TOTAL AREA 1631 SQ FT. LOW LOAD. WORK DONE IN SUITE 345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26598	17041-10000-01483	5241 W HOLLYWOOD BLVD	90027	13	148-5A195  89	5544010020	C2-1D	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.10189	-118.30478	PC FOR ENERGY. CHANGE OF USE FROM MARKET/RETAIL TO RESTAURANT, CONNECTED LOAD < 400A , OCCUPANCY = 81. TOTAL AREA 3135 SQ FT. B#14016-20000-10597	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26599	10041-20000-23987	3410 W SAN FERNANDO ROAD # 5	90065	13	153B209   115	5458003027	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	12/30/2010 12:00:00 AM	ADDRESS	34.11875	-118.25083	energy plan check unit # 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26600	19041-10000-45022	12185 W VENTURA BLVD	91604	2	162B165    57	2367016018	C2-1L-RIO, P-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	06/10/2021 12:00:00 AM	ADDRESS	34.14348	-118.39809	PLAN CHECK FOR TITLE 24 ADD NEW LIGHTS AND EQUIPMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26601	17041-10000-01426	3101 W EXPOSITION PL	90018	10	120B185  1476	5044002015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.02099	-118.33001	Full Plan check. TI to a single floor (E) warehouse building.  Service is existing, all new equipments are reflected on the single line. New lighting and power. Area: 30214 sq.ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26602	13041-20000-02240	8858 N GREENBUSH AVE PV-1	91331	6	195B157   537	2640026005	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.23113	-118.43063	PV-1. Plan check for single family dwelling. Enphase micro inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26603	18041-20000-07369	13171 W OTTOMAN ST	91331	6	195B157    18	2627016011	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.23512	-118.41978	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 5KVA CONSISTING OF 16 MODULES WITH P370 POWER OPTIMIZERS AND 1 SOLAREDGE CENTRAL INVERTER  SE5000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26604	15041-20000-19312	6511 N ORION AVE	91406	6	180B145   559	2234013012	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/18/2015 12:00:00 AM	ADDRESS	34.18901	-118.47076	Installation of new roof mounted solar PV array.  Total system size = 11 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26605	12041-20000-02587	1055 N KINGSLEY DR	90029	13	144B193   801	5537020035	R3-1XL, [T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Apartment			02/03/2012 12:00:00 AM			PC Approved	03/02/2012 12:00:00 AM	ADDRESS	34.09008	-118.30339	T24 lighting plan check for a gym room and outside site lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26606	16041-10000-38362	7029 W WILLOUGHBY AVE	90038	4	144B181   803	5532010041	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	06/26/2017 12:00:00 AM		Issued	06/26/2017 12:00:00 AM	ADDRESS	34.08719	-118.34253	Plan check for Power only, service upgrade from 200A to 800A due to change from one tenant to multiple tenant in an (E) one story commercial building.  Located on Methane Buffer zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26607	19041-10001-09209	2100 N BEACHWOOD DR ev2	90068	4	151-5A189 322	5586012019	R3-1XL, RD1.5-1XL	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Apartment			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.10865	-118.32131	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. CHANGES IN FEEDER AND BREAKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26608	19041-20001-06573	925 S SCHUMACHER DR	90048	5	132B173   124	5088001014	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Issued	06/24/2019 12:00:00 AM	ADDRESS	34.06085	-118.37372	"Revision to approved plans.  Change of module type, change of module quantity, and revised inverter rating.  Permit work description modified to: ""PV1.  Install 5.76 kW DC / 5 kW AC roof mounted grid tied PV system.  (16) modules with 5 kW rated inverter."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26609	11041-20000-08173	485 N HALVERN DR	90049	11	138B141   497	4429021045	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.07142	-118.47453	New 600 amp service.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26610	16041-10001-44765	1741 N CHEROKEE AVE	90028	13	148-5A185  32	5547009014	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.10281	-118.33488	Changes to approved set.  Changing inverter backfeed connection from main service panel to subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26611	13041-10000-26788	19701 S HAMILTON AVE SUITE 210	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	33.85221	-118.28625	TITLE 24 PLAN CHECK ONLY. NO CHANGE IN OCCUPANCY. ( OFFICE)  DEMISING WALL BUILD TO SEPERATE OPEN OFFICE. 2895 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26612	10041-10001-17309	243 S SAN PEDRO ST	90012	14	129A213   469	5161024***	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM			PC Info Complete	12/13/2010 12:00:00 AM	ADDRESS	34.04832	-118.24246	REVISED LIGHTING PLAN-PLAN CHK IS FOR TITLE 24 CHANGE OF USE FROM  (E) RETAIL TO (N) RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26613	14041-20000-24753	5589 E HUNTINGTON DR NORTH	90032	14	147A239   269	5309024018	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.0953	-118.15852	TI IN AN EXISTING COMMERCIAL SPACE. T-24 ENERGY CALCS ONLY. PERMIT FOR NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26614	19041-10000-06205	11351 N TAMPA AVE	91326	12	213B117   389	2701005900	RD2-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.27732	-118.55944	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26615	16041-20000-33324	1 W CENTURY DR #3900	90067	5	132B161   720	4319004***	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Apartment			09/20/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.0567	-118.41497	Plan check for power only. Remodel of penthouse on 39th floor - unit # 3900. > 400A of load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26616	14041-10000-34611	1943 N VINE ST	90068	4	150A187   101	5576019065	R2-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.1065	-118.32681	PV2, INSTALL 18.97 KW DC ROOF-MOUNTED SOLAR ARRAY ON RECREATION CENTER. EXISTING SERVICE. (4) STRINGS, (58) MODULES 327W , (2) INVERTERS, (1)PV LOAD CENTER 240 VAC, AND ONE AC DISCONNECT 240 VAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26617	16041-20001-41064	5845 N PENFIELD AVE	91367	3	174B113    33	2153004032	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.17705	-118.57018	RSES expedited plan check fee.PV1.  Install 12.23 kW roof-mounted grid-tied PV system.  (39) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26618	15041-10001-33517	13274 W VAUGHN ST	91331	7	213B157   292	2524024003	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	PIN	34.28155076	-118.42216255	EXPEDITE PER APPLICANT REQUEST. ((PV1. NEW ROOF-MOUNTED SOLAR SYSTEM ON AN EXISTING HOUSE. TOTAL SYSTEM SIZE IS 3.06KW. (12) MODULES-CANADIAN SOLAR CS6P-255P(1) INVERTER- PVI-3.0-OUTD-S-US-A)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26619	18041-10000-15643	14640 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.22128	-118.45128	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING. 4838 SQFT. inspector to verify if first time tenant for full plancheck. BUILDING PERMIT # 18010-10000-01625	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26620	13041-20000-17011	8905 N GLENOAKS BLVD BLDG B	91352	6	195B173   278	2408008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.23033	-118.36723	TI OF EXISTING SHELL. PROVIDE LIGHTING FOR TENTANT LEASE SPACE. NO BUILD OUT YET. PC FOR T24 ENERGY ONLY. WORK DONE IN BLDG B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26621	18041-10002-32275	6262 N VAN NUYS BLVD	91401	6	178-5A151 200	2240003907	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Issued	08/13/2019 12:00:00 AM	ADDRESS	34.18408	-118.44846	Change to an approved set of plans. All changes are clouded under delta 6. Changes include adding an additial 48 FA devices, revising riser diagram, revising voltage drop, and battery calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26622	14041-10000-13090	2027 W 79TH ST	90047	8	099B189   498	6017030019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	33.96739	-118.31431	PV1, INSTALL 2.55 KW DC ROF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE INTERCONNECT WITH MAI N SERVICE PANEL. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26623	17041-20000-31579	3736 N EUREKA DR	91604	2	162B173   859	2378015024	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.13796	-118.37348	PV1.  Install 13.5 kWh stand-alone energy storage system with (E) solar energy system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26624	19041-10000-14857	13074 W SATICOY ST	91605	2	186B161   428	2303023040	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Issued	04/23/2019 12:00:00 AM	ADDRESS	34.20721	-118.41817	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26625	14041-10000-08604	100 N LA CIENEGA BLVD SUITE C240	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.07466	-118.37629	PLAN CHECK FOR POWER AND ENERGY FOR CONVERTING 3 EXISTING UNITS INTO 2 NEW ONES.6/24/14MODIFICATION WAS FILED IN LUE OF THIRTY DAY METER READING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26626	11041-10003-19293	380 W WORLD WAY FAN ROOM-NO.8	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	on the same level, removing AHU-2 FROM DB5 AND REFEED FROM MCC5Z 800A PANELBOARD; NEW LOAD ON MCC5Z IS 318.8A ; PANEL DB5 HAS LESS THAN 30A LOAD. PLAN CHK ONLYRenovation and addition to existing Tom Bradley International Terminal building-BRADLEY WEST RENOVATIONS: TO EXISTING MCC-5EZX,ADDING 2 EA 10 HP SF UNITS AS PART OF EDN-027AND CHANGES TO LIGHTING TO CORRIDOR AND CS16-56.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26627	17041-10000-05809	10612 W NATIONAL BLVD	90034	5	123B161   849	4314026058	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.03064	-118.41583	Plan check for Title 24 only for The Coffee bean & Tea. Total area: 1441 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26628	15041-20000-20535	11906 W SARAH ST	91607	2	168B169   897	2364004014	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/18/2015 12:00:00 AM	ADDRESS	34.15388	-118.39241	Plan check for a PV1 roof-mounted PV system. Plan check is for the addition of 8.2 kWac system onto an existing 5 kWac system. Total system size is 13.2 kWac. System consists of (1) inverter, (37) modules, (1) combiner box and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26629	13041-10000-15383	201 W SOTELLO ST	90012	1	136-5A217 146	5409003029	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.06692	-118.23009	installation above ground of  propane tank for fleet truck dispensing; this installation is similar installation done by the same contractor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26630	16041-10000-21033	1036 W 51ST PL	90037	9	108B197    69	5002030024	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	33.99586	-118.29289	PV1, rooftop solar installation 6kW AC.    (28) KU2656ZPA   (1) PVI-6000-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26631	13041-10002-30126	4908 N RUPERT AVE	91316	5	168B129   274	2182005033	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	34.15875	-118.52165	Expedited RSES plan check per applicant request.(((PV1, Install 8.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Fronius IG Plus V 7.5. 33 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26632	13041-10000-27277	300 E 9TH ST	90015	14	126A211   210	5145016022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.03985	-118.2534	PC FOR ENERGY ONLY. TI TO EXSITING STARBUCKS COFFEE SHOP.  EMERGENCY LIGHTING EXISTING TO REMAIN. PERMIT TO BE OBTAINED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26633	14041-20001-05012	20522 W HAMLIN ST	91306	3	180B109   566	2148014010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.18901	-118.5806	(((EXPEDITE FEES))) PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.2KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26634	19041-10000-42849	1017 N CROFT AVE	90069	5	144B173   142	5529007042	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	04/14/2023 12:00:00 AM	ADDRESS	34.08945	-118.37446	NEW FIRE ALARM CONSIST OF 1 FA CONTROL PANEL, COMMUNICATOR AND 1 POWER SUPPLY WITH 87 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26635	19041-20003-29289	971 N ENCHANTED WAY	90272	11	132B121   521	4419003019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM			PC Approved	10/02/2019 12:00:00 AM	ADDRESS	34.05435	-118.54914	Revisions to approved plans.  Change of AIC rating of OCPDs to match to (E) installation.  (((Plan check for PV system, PV system size: 19.8KW DC, 18.21KW AC with 60 PV modules and 60 microinverters connected to Existing 600A Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26636	14041-10000-17650	4640 N LANKERSHIM BLVD SUITE 201	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.15499	-118.36841	T24 ONLY. HIGH RISE. T.I FOR OFFICE. TOTAL AREA 9480 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26637	13041-20000-11143	116 N ROBERTSON BLVD #807	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.0758	-118.38356		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26638	14041-20000-31858	11938 W RUNNYMEDE ST	91605	6	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.20563	-118.39354	Roof mounted PV system with optimizers.  PV system 1 of 3 size 4.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26639	19041-10000-06587	12182 W VENTURA BLVD	91604	2	162B165   203	2369004043	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.14316	-118.39793	PC T-24 ONLY  FOR AN EX/INTERIOR T.I OF AN (E) RETAIL SPACE.  SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 1690 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26640	19041-10000-18580	6255 W SUNSET BLVD # 640	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	Tenant improvement to the existing office tenant space #640. Installing new lights.T-24 Energy Only. Bulding Permit: 19016-40000-12533	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26641	16041-10000-13740	20616 W COVELLO ST	91306	3	186B109   378	2113004008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.2073	-118.5825	PV1, rooftop solar installation on SFD, 7.6kW AC.    (32) CS6X-270P       (1) SE7600A        P350 is used.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26642	19041-20000-52666	13021 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	05/21/2020 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.18799	-118.41661	INSTALLATION OF NEW 600 AMP DISTRIBUTION BOARD USING EXISTING 400A SERVICE. PROVIDE NEW PANELS WITH LOADS, 150 KVA TRANSFORMER, AND T24. TOTAL SQUARE FOOTAGE = 3265 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26643	17041-20000-20036	654-656 N NORTH SPRING ST	90012	1	133-5A215 260	5408013007	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Expired	02/28/2023 12:00:00 AM	ADDRESS	34.05867	-118.23831	Plan check for energy only. TI to existing office on 2nd story of commercial building. New lighting (incl. emergency) and receptacles. 2,987sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26644	18041-20000-23107	15300 W PARTHENIA ST	91343	6	195B145   529	2654021038	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.22812	-118.46567	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from restaurant to dental office/tenant improvement. Total lighting area = 1,240 sq. ft.Note: Building application has been generated under 18016-20000-18113	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26645	15041-10001-29561	6540 W HOLLYWOOD BLVD	90028	13	148-5A187 184	5547016005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM			PC Approved	01/08/2016 12:00:00 AM	ADDRESS	34.10142	-118.33231	RECHECKING FOR LOST SET OF PLANS. CHECKING T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26646	14041-20000-30638	8930 N CORBIN AVE	91324	12	195B117    34	2783025080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.23322	-118.56211	REPLACEMENT OF SERVICE EQUIPMENT. REPAIR OF VANDALIZED EQUIPMENT. REPLACE: PANEL, FEEDERS, SERVICE ONLY. NO CHANGE IN LOADS. NO CHANGE IN LIGHTING. ALL LOADS REMAIN FROM EXISTING PANEL SCHEDULES. PULL BOX INSTALLED AHEAD OF PANEL TO ALLOW NEW WIRING INTO THE NEW PANELS.3 PULL BOXES ADDED AS MISC. INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26647	11041-10000-03865	6303 N OWENSMOUTH AVE 3RD-floors	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI IN AN EXISTING OFFICE. EPC IS FOR T24 & LIGHTING. (complete plan check may required by field inspector)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26648	09041-10001-04478	18355 S FIGUEROA ST	90248	15	063B201   204	7339008010	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	01/19/2011 12:00:00 AM	ADDRESS	33.86489	-118.28185	DELTA 3, 4, AND 5 CHANGES TO APPROVED PLANS. NEW PANELS, LOADS & CHANGES TO T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26649	15041-10000-41537	317 S BROADWAY Suite A10	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.05069	-118.24861	NEW RESTAURANT SPACE. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26650	17041-10000-40003	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/26/2020 12:00:00 AM	ADDRESS	34.07196	-118.24719	Plan check for power and energy new elevators added each side of the Dodger Stadium Wings, lighting and newly connected load exceed 400A. Total area: 10,366 sq ft. Note: Single line diagram only apply to 2017 Elevator Scope of WorkB# 16041-10000-02730	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26651	18041-20001-21729	20059 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM			PC Approved	10/31/2018 12:00:00 AM	ADDRESS	34.2756	-118.57118	Revisions to approved set.  Minor changes to underlying architectural layer and lighting plan.  Other miscellenaeous changes. All changes have been clouded and identified as delta-4.  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is a first-time tenant to a movie theater. Total lighting area = 38,400 sq. ft.Note: Building application has been generated under 18016-20000-18638)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26652	13041-20000-26677	4501 N PORTICO PL	91316	5	165B133    29	2289032013	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	34.15244	-118.50698	PV1 TRANSFORMED SYSTEM. TOTAL SYSTEM SIZE 17.331 KW. 53 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26653	15041-20000-13596	15311 W PARTHENIA ST	91343	6	195B145   499	2654012018	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Expired	05/31/2017 12:00:00 AM	ADDRESS	34.22841	-118.46584	SMALL RESTAURANT TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26654	14041-10000-23696	2349 S SANTA FE AVE	90058	14	117A217    26	5167008012	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Apartment			08/29/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.0162	-118.23051	Plan check for power and energy. 1 story apartment (e) building. PLAN CHECK PER INSPECTOR REQUEST FOR adaptive reuse of artist in residence APT CONVERSION from manufacturing. Legalize electrical devices, equipment and lighting system to comply with Department order dated 5/11/11.Partial permit fees already paid under previous electrical applications.BLDG# References:Units A and C12016 10 0485712041 10 21593Units B, D, and E 13016 10 1827213041 100 3435113041 101 34351	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26655	16041-10000-14945	10220 W RIVERSIDE DR	91602	4	165B177   120	2424006005	[Q]C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.15203	-118.35355	PC FOR ENERGY.T.I. to rear office unit to include  patio cover to enlarge office AND ADD NEW RESTROOM. TOTAL AREA 1931 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26656	10041-20000-23101	545 S FIGUEROA ST 5th fl-phase 5	90071	9	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	34.0514	-118.2582	energy plan check 5th floor phase 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26657	18041-10001-46753	400 N MARINE AVE	90744	15	030B205  1269	7418014009	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Approved	02/07/2020 12:00:00 AM	ADDRESS	33.77446	-118.26314	"DELTA ""3"" changes to approved plans. changing loads and affected area.Full PC FOR A CHANGE OF USE FROM WAREHOUSE & MANUFACTURING TO INDOOR NURSERY AND OFFICE. SCOPE OF WORK INLCUDES NEW 1200AMP SERVICE, LIGHTING AND CIRCUITS. TOTAL SQ. FT. 13,120."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26658	11041-20001-08133	1800 S AVENUE OF THE STARS 3rd Floor	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.06095	-118.41786		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26659	17041-20000-01664	3272 S MOTOR AVE SUITE A	90034	5	123B161   952	4314024020	M1-1	West Los Angeles	West Los Angeles			2699.07	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.02978	-118.41091	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAUARANT. "" CITRON CAFE"" 1081 SQFT. SUITE A"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26660	11041-10000-16293	860 S LOS ANGELES ST	90014	14	126A211    98	5145013021	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	12/20/2011 12:00:00 AM	ADDRESS	34.04085	-118.25367	T.I.  Tenant is to take over the 8th floor of a high rise building.  Converting the space into additional studios/ office space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26661	12041-10001-07170	10166 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.25503	-118.57961	SUPPLEMENTAL PLAN CHECK ONLY. PREVIOUSLY APPROVED PLAN CHECK NUMBER IS 12041-10000-07170.****************PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT SUITE 10166 MASON AVE. COMBINE 10166 AND 10168 SUITE TO ONE RESTAURANT WITH TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26662	15041-20001-35839	1350 S UNION AVE	90015	1	127-5A203 225	5135022025	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/04/2015 12:00:00 AM	ADDRESS	34.04331	-118.27757	12/04/2015PLAN CHECK ONLY DUE TO LOST DRAWINGS, INSPECTION FEES PAID UNDER 15041-20000-35839. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP.  TOTAL SYSTEM SIZE IS 2.75KWac. (11) MICROINVERTERS-ENPHASE M250(11) MODULES-LG300N1C-A3)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26663	13041-10001-34514	9145 N RUBIO AVE	91343	12	198B137   838	2687025003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.23702	-118.49559	Expedited RSES plan check per applicant request.{{PV1, Install a 4.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (17) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26664	10041-10000-12423	2149 W WASHINGTON BLVD	90006	10	126B193   920	5074016001	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	PIN	34.04015169	-118.30735008	new luminaires and receptacles at existing churchplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26665	17041-10000-01744	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	PC FOR FA SYSTEM WITH 1188 DEVICES, MAIN PANEL AND 25 POWER SUPPLIES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26666	18041-10000-22307	19524 W NORDHOFF ST	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.23527	-118.55871	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26667	14041-10000-28750	3131 S HOOVER ST Building 9	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			11/07/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.02611	-118.28472	NEW 5-STORY MIXED USE STUDENT HOUSING UNITS & COMMERCIAL RETAIL BUILDING OVER 2 LEVELS OF PARKING GARAGE.  PLAN CHECK FOR POWER AND ENERGY.Note: Total circuits counted 3135 - circuits charged 565OK per Nabil to collect difference under submittal 2 while actual number of hours will be reflected in the assignment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26668	18041-20001-16991	5071 N LLANO DR	91364	3	171B101  1182	2169024013	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM			PC Approved	05/30/2018 12:00:00 AM	ADDRESS	34.16054	-118.60952	Expedite per applicant requestPlan check for PV roof mounted system connected to an existing PV system, New PV system size: 21.96 kWac with 61 AC Modules connected to existing 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26669	18041-10000-35402	444 S FLOWER ST GROUND-FLR.	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLAN CHECK FOR T24, REMODEL LOBBY AND INTALL NEW STOREFRONT SYSTEM. TOTAL AREA: 7,020SQ.FT(B# 18016-10000-18011)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26670	19041-10000-03398	321 N BIXEL ST	90026	1	135A209   190	5160020028	CW	Central	Westlake	Echo Park		2080.00	Electrical	Electrical	Apartment			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	04/16/2020 12:00:00 AM	ADDRESS	34.06418	-118.25512	NEW FIRE ALARM SYSTEM IN THE APT BULDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26671	13041-20000-18633	601 S FIGUEROA ST 19TH FLOOR-SUITE 1975	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	T24 FOR EXISTING OFFICE SPACE/CONFERENCE ROOM FOR HIGHRISE BUILDING ON THE 19TH FLOOR. SUITE 1975. TOTAL SQRFT 4510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26672	14041-20000-31654	4421 S 8TH AVE	90043	8	111B189   346	5014005015	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.00296	-118.32589	PV1. ROOFMOUNTED SOLAR SYSTEM.(12) MODULES(1) INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26673	17041-20000-06291	20018 W STRATHERN ST	91306	3	189B113   507	2106032051	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.21542	-118.56939	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.7KW.  CENTRAL INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26674	19041-20001-13120	6040 W CENTER DR 1-218	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	33.97574	-118.39042	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 71.18 kWdc/65.04 kWac-CEC and consists of (2) inverters, (195) modules, (1) transformer, and (2) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26675	17041-20000-13158	420 E 20TH ST	90011	9	121-5A207  51	5127018011	[Q]CR-1VL-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Issued	05/05/2017 12:00:00 AM	ADDRESS	34.02826	-118.2617	pv2install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26676	11041-10000-20354	11155 W SANTA MONICA BLVD	90025	5	129B153   815	4324035010	M1-1	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	09/30/2011 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	ADDRESS	34.04757	-118.44529	T-24 lighting plan check for an INTERIOR TENANT IMPROVEMENT TO EXISTING STARBUCKS COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26677	19041-20000-49974	3501 W SAN FERNANDO ROAD	90065	13	156B209   332	5458004025	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	10/07/2020 12:00:00 AM	ADDRESS	34.1204	-118.25105	Power and lighting for fire damage repair and addition, existing service and distribution to remain.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26678	16041-20000-38604	6320 N CANOGA AVE Trillium	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check for energy only. New outdoor lighting for open air plaza. 25,692sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26679	16041-10002-39304	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGES TO SINGLE LINE AND PANELS. LOAD UPDATE. NO ADDITIONAL LOADS NOTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26680	16041-20000-38054	9189 N DE GARMO AVE Phase 2	91352	6	198B173   125	2408034042	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Info Complete	12/08/2016 12:00:00 AM	ADDRESS	34.23604	-118.37603	New one story metal warehouse structure to enclose an existing material recovery facility and transfer station operation (recycling facility).  New equipment added to (2) (E) 277/480V services.  Plan check for power and energy  Phase 2 of multi-phase project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26681	17041-10000-12956	767 S ALAMEDA ST Building 2-Ground Fl	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	11/27/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	PC for energy only. T.I on ground floor of exsting 7 story highrise building. New connected load < 400Amps. 2 Retail spaces and corridor.  Total area = 8883 sq ft.     B # 17016-10000-07493	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26682	19041-10000-39909	7150 N TAMPA AVE	91335	3	183B117    99	2129001009	R1-1-RIO, RD2-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	Apartment			10/02/2019 12:00:00 AM			PC Info Complete	01/09/2020 12:00:00 AM	ADDRESS	34.20068	-118.55332	FULL PLAN CHECK FOR NEW SENIOR LIVING CONSISTING OF SENIOR INDEPENDENT HOUSING, ASSISTED LIVING CARE HOUSING AND MEMORY CARE. TWO NEW BUILDINGS WITH FOUR STORY RESIDENTIAL (R2.1 OCCUPANCY) FLOORS TYPE IA CONSTRUCTION, OVER PODIUM OVER SUBTERRANEAN PARKING TYPE IA CONSTRUCTION. SERVICE SIZE 5000A, 480/277V, 3PH, 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26683	13041-20000-09390	15315 W RAYEN ST PV	91343	7	195B145   245	2654005026	M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	05/06/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.232	-118.46599	Plan check for commercial pv system. three 10kw inverters. 31.28kW dc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26684	18041-20001-02558	1938 S BARRY AVE	90025	11	126B149  1099	4262027036	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.03822	-118.44963	pv1Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling.this is plan check only.  permit fees paid under applivcation number 18041-90000-02558	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26685	17041-20002-35357	11647 N BALBOA BLVD	91344	12	213B133   276	2607013008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Expired	04/21/2024 12:00:00 AM	ADDRESS	34.28239	-118.50232	11/16/2017 Changes to an approved set of plans. Changes include the relocation of PV modules in order to comply with LAFD Rule 96 and load calculations to justify MCB change. Derate permit issued under this application.*****Previous Work Description*****PV1. Install roof mounted PV system sized 17.2kW interconnected with MSP.$0 permit fee due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26686	14041-20001-10047	12490 W FIELDING CIR	90094	11	102B161  1250	4211034031	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	33.9788	-118.41237	"4.5.2016 - Plan check for modifications to approved set. Update AIC rating of transer switch ""ATS-E"" to 42kAIC. Available fault current at this ATS switch has been calculated to be ~39,000A. Changes clouded.====New senior living facility: 5 levels of senior living with 175 independent living units, 24 assisted living units and amenity spaces over parking at building foundation level. high rise residential. pc for power and energy. new construction. per building submittal, pc inaccordance to 2008 NEC((NOTE: NEW CONSTRUCTION IN HAZARDOUS LOCATION. PROJECT IN METHANE ZONE)))CUSTOMER HAS PRE-MADE CHECK. ABOUT 90% FEES COVERED. ENSURE DURING PLAN CHECK ADDITIONAL TIME IS ADDED FOR METHANE COMPLIANCE STANDARDS AND FOR UNIT SMOKE DETECTORS. FIRE ALARM VARIANCE WILL NEED TO BE FILED AS A CORRECTION.10/3/14 - fire alarm variance has been filed."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26687	14041-10000-00319	1055 W WILSHIRE BLVD # 1500	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.05232	-118.2629	TITLE 24 FOR A OFFICE BLDG,  SUIT # 1500, HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26688	13041-20000-31716	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.16603	-118.52861	NEWSHELL AND CORE FOR A 4 STORY MEDICAL BUILDING.  BUILDING HAS A 5000A SERVICE AND A 4000A SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26689	19041-10000-19784	411 S HAMEL ROAD	90048	5	138B169   838	4334015014	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			05/24/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	06/10/2022 12:00:00 AM	ADDRESS	34.0716	-118.38189	NEW 4 STORY 37 UNIT APARTMENT OVER 1 LEVEL BASEMENT GARAGE.(FEE ESTIMATE ONLY. CHECK FEES DURING PLAN CHECK)Builing Permit: 18010-10000-02245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26690	17041-10000-03452	5649 E ALHAMBRA AVE	91803	14	141A239    81	5220027902	PF-1	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.07862	-118.16075	PC for indoor title 24. Removing HID fixture and replacing them with new LED ones. Area: 16,525 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26691	17041-10000-14419	759 N SPRING ST	90012	1	133-5A215  38	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/05/2017 12:00:00 AM	PIN	34.06161992	-118.23745547	Title 24 plan check.  T.I. to second floor of existing commercial low rise building.  New lighting and receptacles.  Total area = 4,475 sq. ft.     Building permit #16016-10001-14673       PC only - Electrical permit #17041-90000-13941	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26692	16041-20000-41044	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.17307	-118.59314	TI to (E) commercial office and test facility.  Plan check for energy only.Building permit under 16016-10000-24945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26693	18041-10000-15169	560 S ST LOUIS ST	90033	14	126A221   109	5183019032	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Issued	04/25/2018 12:00:00 AM	ADDRESS	34.03916	-118.21715	REMOVE EXISTING HID FIXTURES AND REPLACE THEM WITH NEW LED FIXTURES. TITLE 24-ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26694	19041-10002-00183	1053 S ORLANDO AVE	90035	5	132B173   596	5087006012	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	34.05771	-118.37399	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE CHANGE OF MODULES TO PV MODULES 330W______________________________________________________PC FOR NEW 10KW AC SFD ROOFTOP SOLAR SYSTEM AND A  ENERGY STORAGE SYSTEM. SCOPE OF WORK INCLUDES (1) 200A LOAD CENTER, (36) 325W DC PV PANELS, (1) 10KW SE10000A INVERTER, AND (2) 5KW TESLA POWERWALL BATTERIES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26695	16041-10000-37039	635 S HOBART BLVD 1ST FLOOR	90010	10	135B193   998	5503028021	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	PIN	34.06232347	-118.30572252	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE GROUND FLOOR. SCOPE INCLUDES NEW LIGHT AND RECEPTACLES FOR AN OFFICE SPACE ON THE GROUND FLOOR. TOTAL AFFECTED AREA IS 968 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26696	19041-10000-47156	12241 W MOORPARK ST APT #1	91604	2	165B165  1313	2364003082	[Q]R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	34.15056	-118.4001	NEW ROOF MOUNTED 3.35KW PV SYSTEM WITH 10  @ (335W) PV PANELS WITH OPTIMIZER AND ONE 3.8KW CENTERAL INVERTER ON AN APARTMENT BUILDING - APT#1	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26697	19041-10000-26264	3435 W WILSHIRE BLVD 8TH FL	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.06194	-118.29866	ENERGY PC ONLY FOR INTERIOR TI TO (E) OFFICE BUILDING TO UPGRADE 8TH FLOOR RESTROOMS. AREA OF SCOPE IS 335SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26698	16041-10001-03787	11729 W BARRINGTON CT	90049	11	135B145   634	4401007008	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			Corrections Issued	03/02/2016 12:00:00 AM	ADDRESS	34.06429	-118.46987	PC for Energy only per inspector. Total area: 920 sq.ft. Permit under 16041-30000-03787<<ADD 4 OUTLET FOR DRYERS, (1) 220 v WATER HEATER OUTLET & 12 LIGHTS.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26699	14041-20001-07083	3020 W WILSHIRE BLVD	90010	10	132B197    30	5077013038	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.06165	-118.28725	Plan check for resizing working area and add some more  type A fixture.(((T24 FOR EXISTING SCHOOL. SCOPE OF WORK ON THE SECOND FLOOR AND IN CLOUDED AREAS ONLY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26700	18041-20000-35959	12100 W WILSHIRE BLVD SUITE 1630	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.0438	-118.46755	Plan check for Title 24 only in existing space high rise building office remodel. New lights, existing circuits. Total area: 2784 sq ft. B#18016-10000-28076	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26701	12041-10000-06322	1544 W PALOS VERDES DR NORTH BLDG H	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77929	-118.30487	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building H. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26702	14041-10000-01808	13752 W VAN NUYS BLVD	91331	7	204B157   287	2646001058	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Expired	02/16/2016 12:00:00 AM	ADDRESS	34.25818	-118.43264	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 640 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26703	16041-20000-02313	21511 W SHERMAN WAY	91303	3	183B105   128	2111018018	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.2012	-118.59942	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a change of use from retail to office. Total lighting area = 1,668 sq. ft.Note: Building permit has been pulled under 15016-20000-27591	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26704	12041-10000-13684	3424 W ADAMS BLVD 1-11	90018	10	123B189   721	5052015033	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM			PC Approved	06/13/2012 12:00:00 AM	ADDRESS	34.03238	-118.32188	Change to outdoor lighting.  Permit was previously pulled on #12041-20000-10146.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26705	18041-20000-33158	777 S FIGUEROA ST 52ND FLR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only in existing space T.I. office space high-rise building newly connected load less than 400A. Total area: 14,167 sq ftB#18016-10000-27045	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26706	13041-20000-03484	13079 W CHANDLER BLVD	91401	5	171B161    87	2345012007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.16873	-118.41784	Plan check for fire alarm system. Chabad of North Hollywood.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26707	19041-10000-42715	11150 W SANTA MONICA BLVD	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM			PC Info Complete	10/22/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	ENERGY PLAN CHECK FOR TI. SCOPE INCLUDES NEW LIGHTING AND  EQUIPMENT WITH A TOTAL LIGHTING AREA 2723 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26708	13041-20000-35107	4255 W LOCKWOOD AVE 1-8	90029	13	144A201   207	5539006024	R3-1	Central	Hollywood	East Hollywood	YES	1914.10	Electrical	Electrical	Apartment			12/17/2013 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.08882	-118.28643	PC FOR POWER AND ENERGY. T24 FOR PARKING ONLY. LOW RISE RESIDENTIAL. NO FIRE ALARM REQUIRED. 8 UNITS. 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26709	17041-10000-08080	13640 W SHERMAN WAY	91405	2	183B157    72	2328008052	C1-1VL, P-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Issued	03/14/2017 12:00:00 AM	ADDRESS	34.20091	-118.43008	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 78275 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26710	11041-10000-05324	6701 S CENTER DR WEST 12TH FLOOR	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM			PC Approved	03/17/2011 12:00:00 AM	ADDRESS	33.97907	-118.39369	T.I. FOR AN EXISTING HIGH RISE OFFICE BUILDING.  T-24, OVER THE COUNTER PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26711	13041-10000-24235	6255 W SUNSET BLVD 9th Floor	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	Remodel of corridors and restrooms on 9th floor of a highrise office building.  Title 24 plan check only for new lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26712	17041-10000-03706	12424 W WILSHIRE BLVD #650	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.04135	-118.47058	TI TO OFFICE SPACES. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26713	16041-10000-27380	877 S FRANCISCO ST	90017	14	129A207   122	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.04791	-118.26383	PLAN CHECK FOR POWER AND ENERGY FOR BLD R2, A  HIGH RISE MIX USE, RETAIL, PARKING, AND RESIDENTIAL BUILDINGS. R-2, RESIDENTIAL  NEW TENANT SPACES FROM FLOORS 5 THROUGH 42 INCLUDING 514 NEW PANELS(14 TYP UNITS) AND ONE 50 HP POWER MOTOR CONNECTED TO EXISTING. METER SWITCHGEAR UPGRADE TO 2000 AMP SERVICES.ORIGINAL CORE/SHELL APPLICATION COVERS BUILDING R2 AND R3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26714	15041-10000-02045	355 S GRAND AVE #1600	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.05191	-118.2525	Plan check for T-24 only for suite renovation for landlord. Total area: 2863SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26715	17041-20000-37074	8745 N GOTHIC AVE	91343	12	195B137   683	2688038026	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Closed	04/07/2023 12:00:00 AM	ADDRESS	34.22978	-118.48969	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter and (19) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26716	13041-10000-07461	4477 W WILSHIRE BLVD	90010	4	135B185   566	5505014***	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.06207	-118.32722	"Upgrade of fire alarm system for a 4 story building due to fire damage. 137 devices and 1 fire alarm panel.""COMPLY WITH DEPARTMENT ORDER effective date02/07/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26717	15041-10003-06920	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.06326	-118.20213	*** REVISION TO THE APPROVED SET OF PLAN, ALL CHANGES IS UNDER DELTA N2:ADD AND REMOVE BRANCH CKTS.**REVISION TO THE APPROVED SET OF PLAN, ALL CHANGES IS UNDER DELTA N1:ADD AND REMOVE BRANCH CKTS, CHANGES ON T-24.*Plan check hours charged due to initial applicant submittal of wrong set of plans. (((New 5 story Medical Building. Includes Power & Energy and OSHPD  3 PLAN REVIEW.Core & Shell was approved under 14041-10000-29044<<Fee Calcs were provided by applicant with a preprinted check. Fees to be verified during EPC>>)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26718	11041-10000-22043	1290 S LA CIENEGA BLVD	90035	5	129B173    20	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.05352	-118.37593	title 24 and emergency exit sign.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26719	17041-10000-06076	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.2426	-118.55846	TITLE 24 FOR RETAIL TI (SPORTS EQUIP) OF THE GROUND FLOOR OF A TWO STORY EXISTING STRUCTURE. TOTAL SQ. FT.(23423)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26720	12041-10000-16122	4251 S CENTRAL AVE	90011	9	114A209   159	5115018033	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Apartment			07/12/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.00652	-118.2567	Modification to lighting in an existing apartment complex.  Load is 365.2Amps.  Plan check only for Energy, with Emergency lighting,  in the Common Areas only.  Permit Fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26721	15041-20000-21001	5117 W SANTA MONICA BLVD	90029	13	144B193   693	5537017024	C2-1D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.09097	-118.30106	TI to existing commercial building (bakery). Plan check for energy only. Adding new lighting including emergency. Total sqft. 2,800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26722	10041-20000-24220	15760 W VENTURA BLVD 14th FL	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM			PC Info Complete	01/26/2011 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check T-24 Energy (general/emergency) lighting for office TI on the 14th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26723	14041-20000-22440	2124 N NORTH BROADWAY	90031	1	138A221   110	5204006007	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.07336	-118.21807	Electric service upgrade and consolidation of 2 services into one.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26724	16041-20001-23276	5955 W SATURN ST 1-29	90035	10	129B173   629	5068012039	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			06/14/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.05039	-118.3702	06-14-20018 Changes tto an permitted set of plan. Changes include of conduit seal off and re-route of conduit from Under Ground Pull Section to Transition Section Pull Section. All Changes has been clouded as delta C. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26725	14041-20000-03782	13333 W DEL SUR ST	91340	7	213B157   213	2524019010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.28208	-118.4239	pv1 single family dwelling. total system size 3kw ac using transformerless inverters nonstandard plan. using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26726	10041-10000-14095	444 S SAN VICENTE BLVD # 603	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	10/29/2010 12:00:00 AM	ADDRESS	34.07021	-118.37547	Ti in an existing office. Plan check for T24. (Mark Goodson Bldg, 6th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26727	19041-20000-20034	1530 S GREENFIELD AVE	90025	5	129B153   289	4324023005	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.05126	-118.44334	PV2.  Install 3.2 kW roof mounted grid tied PV system.  (10) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26728	16041-20000-04738	432 S VAN NESS AVE	90020	4	135B189   517	5504020017	R1-1XL-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	04/16/2016 12:00:00 AM	ADDRESS	34.06612	-118.31499	PV1.  Install 4.3 kW roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26729	16041-10000-43026	1901 S AVENUE OF THE STARS	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.41705	PC FOR OUTDOOR LIGHTING. TOTAL AREA 13800 SQ FT. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26730	14041-20001-06426	4100 S DEL REY AVE	90292	11	108B153  1216	4230005040	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM			PC Approved	05/14/2014 12:00:00 AM	ADDRESS	33.98857	-118.44494	(((EXPEDITE FEES)))PV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 64.2KW AC USING MULTIPLE INVERTERS WITH MULTIPLE STRING INPUTS. USING TOTAL OF 288 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26731	19041-20000-45023	4611 N YOSEMITE WAY	90041	14	160-5A219 152	5683036009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Issued	11/04/2019 12:00:00 AM	ADDRESS	34.13433	-118.22349	PV1. INSTALL 7.56 KW DC PV SYSTEM WITH (24) MODULES/OPTIMIZERS AND (1) INVERTER(SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26732	14041-20001-07719	5701 N BECKFORD AVE	91356	3	174B117   188	2156005014	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	34.17439	-118.55161	((Expedite fees))PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 13KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26733	14041-10000-24475	9912 N MARNICE AVE	91042	7	201B205   400	2571016063	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.24743	-118.27179	PV1, INSTALL 5.255 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(21) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): ABB PV1-4.2-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26734	17041-10000-35317	2200 W 7TH ST	90057	1	132A203    64	5141017001	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05689	-118.27811	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 2700 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26735	15041-10000-17744	1359 S HOPE ST	90015	14	126A207   246	5134012020	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.03808	-118.26683	FIRST TIME TENANT.  SERVICE UPGRADE TO 800 AMPS.  NEW PNELS AND CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26736	17041-10000-15340	19156 W MAYALL ST	91324	12	204B121   393	2729025025	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.25391	-118.55141	PC FOR PV SYSTEM ROOF MOUNTED. USING MICROINVERTERS. ENPHASE M250. USING 32 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26737	12041-20000-05935	17250 W VENTURA BLVD	91316	5	168B133    34	2289005020	C2-1VL, P-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Expired	06/25/2014 12:00:00 AM	ADDRESS	34.16056	-118.50919	T.I. to existing building (US Bank).  Replace lighting in financial transaction area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26738	18041-10000-06831	19809 W HEMMINGWAY ST	91306	3	189B113   700	2106025016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.21414	-118.56483	PC FOR ROOFMOUNTED PV SYSTEM. SCOPE INCLUDES 16 MODULES (SUNPOWER X22-360-D-AC) WITH INTEGRATED MICROINVERTERS AND A  LOAD CENTER. SYSTEM SIZE IS 5.76KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26739	16041-20000-13732	6420 W WILSHIRE BLVD Floors 3-4	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.06365	-118.36922	Upgrades to 3rd and 4th floor common area restrooms and lobbies in an (E) commercial office highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26740	18041-20001-14339	816 W BARTLETT ST	90012	1	135A213   320	5407004041	R4-1	Central	Central City North	Historic Cultural	YES	2071.01	Electrical	Electrical	Apartment			12/14/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.06279	-118.24496	12/14/2018 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is parking garage and common area lighting. Total lighting area = 21,162 sq. ft.*****Original Work Description*****REMOVE AND REPLACE LIKE TO LIKE LIGHT FIXTURES - DEVICES SMOKE DETECTORS 33 UNITS COMMON AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26741	11041-10000-04119	1862 S LA CIENEGA BLVD	90035	10	126B173   416	5066005011	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Info Complete	03/03/2011 12:00:00 AM	ADDRESS	34.04276	-118.3762	TI IN AN EXISTING STORE.   PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26742	18041-20002-45018	6214 W LA MIRADA AVE	90038	13	144B189   258	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.09334	-118.32501	3/26/2019changes to an approved set of plans.  changes to the interconnection point.  addition of 200 amp OCPD.this is plan check only.  ((((Plan check for a PV2 roof-mounted PV system. System size is 35 kWdc/34.2 kWac and consists of (3) inverters, (100) modules, and (1) load center.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26743	10041-10001-08511	15840 W MONTE ST B-102	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM			PC Approved	06/02/2010 12:00:00 AM	ADDRESS	34.31015	-118.47604	INSTALL (4) 120V  20AMP CIRCUITS, INSTALL (1) CIRCUIT FOR A/CinOFFICESplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26744	19041-20000-53525	4832 N ALMIDOR AVE	91364	3	168B093   141	2074040013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.15822	-118.63338	PV1. INSTALL 14.85 KW DC/14.175 KW AC ROOF MOUNTED PV SYSTEM WITH (45) MODULES AND MICROINVERTERS (ENPHASE IQ7X-96-2) AND A COMBINER BOX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26745	17041-20000-00044	7500 N LANKERSHIM BLVD	91605	2	186B169   461	2316013003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.20684	-118.38758	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 13294.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26746	14041-20002-00334	10451 W BELLAGIO ROAD	90077	5	141B153   180	4362020004	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2017 12:00:00 AM			PC Info Complete	08/09/2017 12:00:00 AM	ADDRESS	34.08138	-118.43908	[[[7/26/17 CHANGES TO APPROVED SET. DELTA 3 CHANGES ARE CLOUDED. CHANGES TO POWER, AND LIGHTING, NEW UNDERGROUND GARAGE WITH CAR CHARGERS AND ELEVATOR LIFT]]]]SEE COMMENTS...........BUILDING PERMIT # 13010-10002-043755/18/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES. RELOCATION OF MAIN SWITCHBOARD, CHANGES IN FEEDER SIZES, REVISED AIC CALCS AND VOLTAGE DROP(((pc for power and energy. NEW SFD, 2-STORY W/ BASEMENT GARAGE (13010 10000 04375). with 60kw optional standby generator  (Plan check per 2010 LAEC) electrical permit have been paid under the building  app #13010-10000-04375)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26747	17041-10001-44240	1848 S CRESCENT HEIGHTS BLVD	90035	10	126B173   437	5066009010	R1R3-RG	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.04277	-118.37477	void for not able to collecting the investigation fee.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26748	12041-10000-13779	1259 S UNION AVE	90015	1	127-5A203  36	5137033029	[Q]C2-1-HPOZ	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.04535	-118.27676	Plan check for energy and emergency lighting for an existing retail space. 1900 sqft. Tailored method.  Load is less than 400Amps.  Permit Fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26749	18041-10002-06186	748 N AMALFI DR	90272	11	126B133   118	4408015006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.04237	-118.51108	This is plan check only to indicate the short circuit rating on the single line diagram per available fault current.[PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL 5.8KVA) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL(200A)].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26750	13041-20000-15643	655 E WESTMINSTER AVE	90291	11	108B145   274	4239019040	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			06/13/2013 12:00:00 AM			Reviewed by Supervisor	06/25/2013 12:00:00 AM	ADDRESS	33.99486	-118.46608	UPGRADING SERVICE, SWITCH BOARD, UNIT PANELS, AND HOUSE PANEL FOR 2 STORY 8 UNIT APARTMENT BUIDLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26751	13041-10000-18006	1263 W TEMPLE ST	90026	1	136-5A209 349	5160023014	CW	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Approved	07/09/2013 12:00:00 AM	ADDRESS	34.06637	-118.25408	Renovations to existing building. New circuits and led lighting. 1 story.  1 Sub panel. 15 circuits and lighting. Title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26752	14041-10000-28059	4251 W BEVERLY BLVD	90004	13	138B193   477	5521034015	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.07643	-118.3016	"Investigation fee added.PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURAUNT. NO CHANGE IN OCCUPANCY. 3368 SQFT, EMERGENCY LIGHTING. ""COMPLY WITH DEPARTMENT ORDER effective date 01/23/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26753	17041-20000-41255	1800 CENTURY PARK EAST SUITE 400	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	PIN	34.06270629	-118.4150769	PLANCHECK FOR T24 ENERGY. Tenant improvement on 4th floor in (E) 19 story office building.  SUITE 400BUILDING PERMIT # 17016-10000-29842	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26754	18041-10000-08639	1 W WORLD WAY	90045	11	090B165    93	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			Corrections Issued	03/09/2018 12:00:00 AM	PIN	33.94415688	-118.4024579	PC FOR OUTDOOR LIGHTING IN LAX FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW OUTDDOR LIGHTS CIRCUITS AND PANELS.B# 18016-10000-03241	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26755	19041-10000-15090	355 S GRAND AVE 2200	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	06/28/2020 12:00:00 AM	ADDRESS	34.05191	-118.2525	T-24, PC for energy only. TI for an office space on the 22nd Floor. Total affected area is 7985 Sq. Ft. B#18016-10000-33826	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26756	16041-10000-41975	1800 W SLAUSON AVE	90047	8	108B193  1367	6001001026	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.98888	-118.30923	PC FOR T24 ENERGY ONLY. REPLACEMENT OF LUMINAIRES TO MORE ENERGY EFFICIENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26757	18041-20000-48686	864 S ROBERTSON BLVD 2nd floor	90035	5	132B169   100	4333015025	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			12/26/2018 12:00:00 AM			PC Info Complete	12/26/2018 12:00:00 AM	ADDRESS	34.06106	-118.38339	Plan check for Title 24 only tenant improvment  on 2nd floor office space. Total area: 2638 sq ft. B#18016-30000-40299	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26758	12041-10001-01627	22115 W ROSCOE BLVD	91304	12	192B101   520	2010023034	(T)(Q)C1.5-1, C2-1L, P-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			PC Approved	07/05/2012 12:00:00 AM	ADDRESS	34.21979	-118.60892	Title 24 previously approved,  changes made is switching changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26759	09041-20003-24427	6317 W WILSHIRE BLVD	90048	5	135B177   468	5510028004	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	03/29/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.06368	-118.36592	Plan check for Delta 17. Revision to approved plans are clouded. New circuits, equipment, panel, service load revision, and revision to panel loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26760	13041-10000-00964	8500 W BEVERLY BLVD #676	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM			PC Approved	01/14/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT OF AN (E) 611 S.F. RETAIL SPACE IN A COVERED MALL; PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26761	10041-10000-02695	14500 W ROSCOE BLVD #215	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	03/15/2010 12:00:00 AM		Permit Closed	05/17/2010 12:00:00 AM	ADDRESS	34.22136	-118.44937	Ti , title 24 energy in an existing doctors office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26762	13041-10001-07456	18025 W MEDLEY DR	91316	5	165B125   261	2184033006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.14753	-118.52562	SUPPLEMENTAL TO 13041-10000-07456. ADDITION OF FOUR MODULES. 1 ADDITIONAL MODULE PER STRING.[INVERTER: FRONIUS # IG PLUS V 10.0 |||| MODULES: TRINA # TSM-245PC05]*********************************************13041-10000-07456 DESCRIPTION: PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWLELING. TOTAL SYSTEM SIZE 12.48 KW. USING 48 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26763	16041-30001-08448	13630 W SATICOY ST	91402	6	186B157   140	2214025004	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.20928	-118.42941	Expedite per applicant request{{{{Plan check for PV system on conbination of roof mount and new carport in existing roof. Total system size: 302.2kW with 828 modules and 6 inverters(STP24000TL-US) and 2 inverters(STP2000TL-US) connect to supply side tap.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26764	17041-10000-10722	3909 S GIBRALTAR AVE	90008	10	117B177   277	5030002900	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.01637	-118.35488	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 7,475. total of 15 units	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26765	11041-10000-18031	515 S FLOWER ST 4TH FL	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26766	11041-20000-08122	200 S EARLE ST Berth-225-232	90731	15	018B205    68	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	33.746	-118.26721	Canopy mounted P.V. with 59.94 KW for Port of L.A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26767	15041-10000-00260	810 E PICO BLVD	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.03119	-118.25079	Plan check for a new fire alarm system consisting of 381 devices, and 1 FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26768	19041-10001-31986	110 E 9TH ST 9TH FLR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	Change to an approved set by removing all track lighting from the floor plan. All changes under delta-1 Only.(((Energy plan check for a partial office T.I located on the 9th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 25,852-SQ FT )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26769	19041-20001-21926	14136 W ATTILLA ROAD	90402	11	123B129   373	4410027002	R1H1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	12/08/2020 12:00:00 AM	ADDRESS	34.03393	-118.51159	09-10-2019 Changes to an approved set of plan, Changes include addition of work install 2 Tesla PowerWall 2.0(13.5KWh), addition of 3 PV Modules, relocation equipment, Update PV system size: 12.60KW DC, 11.462KW AC. Energy Storage System size: 27KWh. All Changes has been clouded. Note: fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26770	17041-10001-00937	3673 S WELLINGTON ROAD	90016	10	117B185    43	5046027005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM			PC Approved	12/15/2017 12:00:00 AM	ADDRESS	34.02073	-118.33841	12-15-2017 Changes to an approves set of plans. Changes include change manufacture from Hyundai HIS-5290RG to Canadian Solar CS6X 315. This is plan check only permit is cover under 17041-20000-00937	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26771	13041-10001-32078	1436 N VIA CRESTA	90272	11	132B125    17	4420040001	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.05685	-118.53728	Expedited RSES plan check per applicant request.(((PV1, Install 16.47 kW DC roof-mounted solar array, interconnect with service panel.Non standard plan. 61 Microinverter. Enphase M215. 61 modules solarworld SM270.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26772	15041-10001-40497	645 N TUALLITAN ROAD	90049	11	138B137   631	4494010003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.07123	-118.48491	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL A 16350 W DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(2) INVERTERS: FRONIUS USA PRIMO7.6 240V(50) MODULES: SUNPOWER SPR-E20-327 W>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26773	16041-10001-10068	2134 W SUNSET BLVD BLDG A	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Approved	05/05/2017 12:00:00 AM	ADDRESS	34.07723	-118.26485	Changes to approved set.  Change to lighting fixtures and updated Title 24.  New photometric calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26774	14041-20000-17602	6255 W SUNSET BLVD P2	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Issued	07/02/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	TI to mail room of (E) parking structure.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26775	14041-20000-22317	9251 N WOODLEY AVE	91343	12	198B141   487	2676014025	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.23899	-118.48523	Standard plan, 5.8KW PV1 roof-mouned system including: (1) Power One PVI -6.0-OUTD inverter and (23) Trina Solar TSM-255 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26776	16041-10000-39767	3600 N BARHAM BLVD Y	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Info Complete	11/10/2016 12:00:00 AM	ADDRESS	34.13829	-118.34154	PC FOR ADDITION OF LAUNDRY CIRCUIT WHICH IS COMBO UNIT WASHER AND ELECTRIC DRYER. TOTAL OF 182 UNITS BEING ALTERED. FULL PC FOR NEW CONNECTED LOADS GREATER THAN 400A this is permit for unit Y	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26777	14041-20000-13996	21600 W OXNARD ST #1100	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.179	-118.6002	T.I. to existing high rise building partial of 11th floor.  Install and relocate lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26778	17041-10000-07210	1448 N ALVARADO ST	90026	13	141A209   125	5419019022	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1956.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.0819	-118.26067	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 4550 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26779	19041-10000-46847	13945 N CLAYWOOD AVE	91342	7	231B157   314	2582018001	RS-1	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	02/15/2020 12:00:00 AM	ADDRESS	34.32659	-118.42712	ROOF MOUNTED PV1 SYSTEM. SYSTEM SIZE 4.65KW DC/ 3.80KW AC. SYSTEM INCLUDES 15 (MISSION SOLAR ) MODULES, 1 CENTRAL INVERTER (SE 3800H-US). MAIN SERVICE PANEL UPGRADE TO BE SEPERATELY PERMITTED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26780	11041-20000-01080	13912 W SATICOY ST	91402	6	186B153    32	2214023020	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	34.2102	-118.43599	PLAN CHECK FOR ROOF MOUNTED 15.8KW AND 29.9KW PHOTOVOLTAIC SYSTEM FOR 2 EXISTING SERVICES SUPPLYING ONE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26781	16041-20000-11019	5042-5044 N VINELAND AVE	91601	2	171B173  1000	2419003002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	PIN	34.16242241	-118.36995864	Plan check for energy only. TI to hookah lounge. New lighting (incl. emergency). 1,300sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26782	10041-20002-20754	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM			PC Approved	04/04/2011 12:00:00 AM	ADDRESS	34.10137	-118.34182	REVISE DIMMING CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26783	15041-20000-19278	7615 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.20906	-118.46494	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 3.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26784	17041-20001-22566	6240 W SUNSET BLVD	90028	13	147A189    64	5546025003	(T)(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.09778	-118.32504	Revisions to approved plans.  Change of lighting control details and dwelling unit feeder detail revisions.  Changes clouded and identified.  (((New 7 story mixed use building with 200 dwelling units.  3000A 480/277V 4w 3ph service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26785	11041-10000-21232	1057 N VINE ST	90038	4	144B185   814	5533017010	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.09007	-118.32679	Ground up renovation for an existing hotel.  New service, all new circuits and panels and equipment, including PV system.  Plan check for POWER and Energy.  Variance will be filed to seperate fire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26786	13041-10001-03990	8231 W 3RD ST SUITE E	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.07272	-118.36914	Modifications to lighting fixtures and updated Title 24 sheets.  Newly added emergency lighting.(((POWER+ENERGY TI 1ST TENANT SPINCYCLE STUDIO (12016-20000-25795). 3 stories. methane but no underground work.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26787	12041-10000-31139	22100 W GERMAIN ST	91311	12	207B101   172	2723015071	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11, 1132.12	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	04/02/2013 12:00:00 AM	ADDRESS	34.26228	-118.6081	PV1 SINGLE STORY HOUSE. 55 MODULES AND USING 2 DIFFERENT TYPES OF INVERTERS ONE OF EACH. [MODULE: SUN TECH {STP190S}] [INVERTER: POWER-ONE {PVI-5000-OUTD-US} AND {PVI-6000-OUTD-US}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26788	16041-10000-09208	3500 W WILSHIRE BLVD	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.06157	-118.30077	"TI to an (E) commercial build. Re-feeding panelboards under the  ""HDB"" and ""CDB"" total load over 400A. PC for Power and Energy. (2000MSA under separate permit).  Total area: 14,511 sq.ft indoor + 13,481 sq.ft outdoor."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26789	18041-10000-13519	8941 N TAMPA AVE	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.23285	-118.55413	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26790	19041-20001-27114	9710 N VANALDEN AVE pv1	91324	12	201B121   368	2762032011	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Issued	08/30/2019 12:00:00 AM	ADDRESS	34.24738	-118.54905	08-30-2019 Changes to an approved set of plan, changes include change inverters to 1 inverter(11.4KW) and reduce number of PV Modules to 36 and System size: 11.34KWFees $0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26791	12041-10000-06470	621 S WESTERN AVE # 215	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TENANT IN RETAIL STORE AT  EXISTING SHOPPING MALL (NO CHANGE OF USE).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26792	16041-20000-22208	16000 W VENTURA BLVD #1100	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.15584	-118.48164	Plan check for Title 24 only in existing office space T.I.  Total area: 5,275 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26793	16041-30000-24770	937 N HUDSON AVE	90038	13	144B185  1027	5533023005	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.08826	-118.3322	Plan check for a fire alarm system for a existing apartment building. Fire alarm system consists of (1) FACP and (45) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26794	13041-10000-01886	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.06188	-118.30486	New lighting in courtyard for temple. All exterior lighting. 3325 sqrft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26795	13041-20001-26752	7441 W KYLE ST	91042	7	207B197   397	2566013071	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	34.26545	-118.29469	(((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.3 SKW AC USING 20 MICROINVERTER ENPHASE M215. NONSTANDARD PLAN. PC REQUIRED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26796	10041-10000-12332	441 S HEWITT ST	90013	14	127-5A215 339	5163022020	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM			PC Approved	08/16/2010 12:00:00 AM	ADDRESS	34.04238	-118.2353	T-24 and emergency lighting plan check for a remodeled building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26797	17041-20001-20130	4930 N GAVIOTA AVE	91436	5	168B141   207	2261020046	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.15925	-118.4808	Revision to approved plans: (1) additional Powerwall added to the design; relocation of equipment.  (((Plan check for AC coupled battery backup system.(1) 5kW Tesla Powerwall 2.Existing solar system on roof.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26798	19041-20000-32922	10635 W STAGG ST	91352	2	189B177   577	2466030024	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM			Reviewed by Supervisor	11/19/2019 12:00:00 AM	ADDRESS	34.21216	-118.36301	POWER AND ENERGY PLAN CHECK FOR TI TO EXISTING OFFICE/WAREHOUSE. NEW DISTRIBUTION EQUIPMENT, PANELS, AND LOADS. T24 INCLUDED TOTAL SQUARE FOOTAGE = 56,420 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26799	14041-10001-11761	6033 S CENTRAL AVE	90001	9	105B209    92	6007007022	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			PC Approved	09/05/2014 12:00:00 AM	ADDRESS	33.98492	-118.25673	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26800	16041-10001-43693	1035 N SWARTHMORE AVE BLDG 01	90272	11	129B125   837	4423016022	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	Delta 59 changes - changes to outside / landscape light. Added 2 ea new cktsCHANGES ARE CLOUDED AND MARKED ON SHEET 01.EP1.2.01((((((Full Plan check for new retail and theatre building, core and shell, 1 story. New service rated at 5000 Amps 480/277V 3phase 4wire. Indoor and outodoor title 24. Total area: 7250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26801	16041-10000-39853	21201 W ITASCA ST	91311	12	201B105   212	2746006014	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.24489	-118.59453	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26802	13041-10000-24610	5341 N NATICK AVE	91411	4	172-5A149  87	2249018010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Expired	10/05/2015 12:00:00 AM	ADDRESS	34.16796	-118.45437	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION; INTERCONNECT WITH MAIN PANEL ON A CENTRAL INVERTER STANDARD PLAN. 2-STORY HOUSE.SYSTEM SIZE 7.5KW DC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26803	12041-10000-09656	8575 N 3RD ST	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	PIN	34.07409781	-118.37885799	This is a high rise bldg , remodeling all elevator lobbies, breack room  , power and energy. emergency by gen set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26804	14041-10000-00621	1023 S VICTORIA AVE	90019	10	132B189  1105	5082019002	R1-1-O	Central		Olympic Park		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Expired	09/20/2017 12:00:00 AM	ADDRESS	34.05452	-118.32462	PV1.  Installation of 7.344 kW roof-mounted PV utility-interactive system, interconnect with main service panel.  Microinverter standard plan: Enphase M215-60-2LL-522.  34 modules: E&H CO LTD EHS3-250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26805	15041-20000-21589	11709 N PINE VALLEY PL	91326	12	213B117    27	2822020030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.28441	-118.55863	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26806	19041-20000-39525	1005 E WASHINGTON BLVD # C	90021	14	121-5A211 353	5131003026	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.02589	-118.25311	Plan check for Title 24 Energy for manufacturing(non hazardous location) accessory office, storage. Total area: 3248 sq ft. B#19016-20000-00587	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26807	12041-10000-00267	10250 W SANTA MONICA BLVD #1240	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to an existing retail space at a mall.  Relocating 2 panels and a 75kva transformer, lighting changes and additional circuits.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Loads have not been plan checked.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26808	12041-20000-01999	8153 N WOODMAN AVE	91402	6	192B157   905	2213017003	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.21895	-118.43181	Photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26809	13041-10000-23778	19532 W TRIBUNE ST	91326	12	207B117   115	2708006011	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.26654	-118.55874	PV1 10.78KWdc 240V XFMR INV. 2STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 44) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26810	14041-20000-08011	12700 W VENTURA BLVD SUITE 400	91604	2	162B161    29	2384022039	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.14449	-118.40998	New light fixtures, sensors, and exit signs for tenant space in 4-story commercial office building.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26811	12041-20000-19638	20516 W DEVONSHIRE ST	91311	12	204B109   514	2741025181	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.25702	-118.58043	Plan check for energy and emergency lighting. Bank of the West.  3001 indoor sqft, 610 outdoor sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26812	17041-10000-06346	115 W 25TH ST	90007	9	121-5A205 183	5126035012	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.02624	-118.26865	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING ELECTRICAL EQUIPMENT DUE TO FIRE DAMAGE. ADDING ONE NEW PANEL, NEW LIGHTS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 3685 SQ. FT. B#17016-10000-00362	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26813	15041-20000-14308	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022	A1-1-H, A2-1, PF-1XL, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.08694	-118.47588	Plan chek for title 24 only install 2 new out door light poles mount luminaires at north Entrance. Total area: 8850 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26814	13041-10000-26014	380 WORLD WAY # T63R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of 1 led self-illuminated sign on the external walls of a the tenant space The Hollywood Reportwel  on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling thesign .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26815	13041-20000-29445	18700 W VENTURA BLVD # 220	91356	11	174B121   811	2161026002	(Q)C2-1VL, C2-1VL, R1-1	South Valley	Encino - Tarzana	Mar Vista, Tarzana		2719.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.17045	-118.54081	TI for gym	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26816	13041-10000-35857	9620 S AIRPORT BLVD	90045	11	093B169   171	4125023034	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	05/07/2014 12:00:00 AM		Issued	05/07/2014 12:00:00 AM	ADDRESS	33.94842	-118.38574	INSTALLATION OF NEW FIRE ALARM DEVICES WITH UPGRADES TO PANELS. TENANT IMPROVEMENT TO RENAISSANE HOTEL LAX. 6 PANELS AND 1998 DEVICES. HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26817	14041-20000-22174	19223 W KNAPP ST	91324	12	198B121   539	2762036022	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.23828	-118.55123	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.(1) SolarEdge SE6000A transformerless inverter(21) SolarEdge P400 power optimizers(21) SunPower SPR X21-345 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26818	10041-20000-12001	555 W 5TH ST 8th Floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check T-24 Enegy for general lighting on the 8th floor. Add fixtures and relocate fixtures in office/conference room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26819	15041-10000-42862	3755 W 60TH ST	90043	8	105B185   388	4004018013	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM			PC Info Complete	12/18/2015 12:00:00 AM	ADDRESS	33.98547	-118.33964	PV1 7.3KW roof-mounted system with (34) Sun Edison SE-F265CYC  modules and (34) Enphase Microinverter, and (1) loadcenter panel interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26820	12041-10000-08880	2607 W SUNSET BLVD	90026	13	141A205   215	5402015023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake		1956.00	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			Corrections Issued	03/07/2013 12:00:00 AM	ADDRESS	34.08024	-118.26981	Relocate and upgrade the main switchboard to 800A, new panels, new circuits.  Existing single story building.NEW APPLICATION WAS GENERATED. THIS APPLICATION HAS BEEN WITHDRAWN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26821	16041-10002-05064	5050 N CHICOPEE AVE	91316	5	171B129   356	2257018026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.1628	-118.51222	CHANGES TO APPROVED SET OF PLANS. CHANGES SHOW DISTRIBUTION EQUIPMENT SUPPLYING PV SYSTEM. NOW SHOWING BREAKER SUB FEEDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26822	19041-10000-49291	1836 N LAUREL CANYON ROAD	90046	4	150B177   423	5569034008	R1-1-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.10467	-118.36611	0$ final fees per AB1414NEW ROOFTOP SOLAR SYSTEM CONSIST OF 41 MODULES (Q-PEAK 380) WITH 41 OPTIMIZER ( SE P400) AND 2 CENTRAL INVERTERS (SE 7600H-US EACH). SYSTEM SIZE IS  15.58KWDC AND 15.2KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26823	15041-20000-35377	1101 S HARVARD BLVD 1-40	90006	10	129B193   631	5080021027	R3-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Apartment			10/22/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.05066	-118.30443	Plan check for Fire alarem System in 40 units appartment 4 stories building. Total devices:264	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26824	15041-10000-18479	1010 N GAFFEY ST	90731	15	021B197   527	7448002033	M1-1VL	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	33.75326	-118.29191	FULL PC FOR ENERGY AND POWER FOR NEW BUILDING, NEW CAR WASH BUILDING. 2008 TI-24 FORMS BUILDING SUBMITTED BEFORE JULY 2014. 800AMP SERVICE 120/240V SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26825	14041-10000-02296	10826 W KLING ST	91602	2	168B173   742	2421024019	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			01/27/2014 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.1555	-118.36671	INSTALLATION OF NEW FIRE ALARM SYSTEM IN 12 UNIT APARTMENTS, CONSISTING OF 83 DEVICES , (1) FACP, 1 ANNUNCIATOR PNL. 4 STORIES + ROOF & GARAGE. TOTAL AREA OF BUILDING IS APPROX. 30,971 SQ FT, WITH AUTOMATIC FIRE SPRINKLER SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26826	18041-10002-28134	4867 W SUNSET BLVD	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Los Feliz	Yes	1912.01	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.09832	-118.29564	PLAN CHECK FO CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE CONDUIT RE-ROUTING AND CHANGES TO MAIN METTER AND DISCONNECTS - CHANGES HAVE BEEN CLOUDED UNDER DELTA 4 AND B1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26827	18041-10000-36496	13003 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	01/30/2019 12:00:00 AM		Issued	01/30/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	ENERGY PLAN CHECK FOR A NEW TENANT IMPROVEMENT FOR COFFEE SHOP; SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTALAREA OF 1725-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26828	14041-20000-10410	444 S FLOWER ST 11th Fl.	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	T.I. to a high rise building on the entire 11th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26829	17041-10000-04989	1541 S PALOS VERDES ST	90731	15	012B201   400	7456020017	R2-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	33.72984	-118.28153	PV 2520 W DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE. (9) MODULES: HANWHA Q-CELL  Q-PLUS BFR-G4.1 280(9)OPTIMIZERS-SOLAREDGE P300 (1) INVERTER: SOLAR EDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26830	16041-10000-39506	8759 N SEPULVEDA BLVD	91343	6	195B145   399	2654013008	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.23006	-118.46788	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26831	14041-20000-17692	633 W 5TH ST 10th floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Issued	08/07/2014 12:00:00 AM	ADDRESS	34.05099	-118.25468	TENANT IMPROVEMENT OF SUITE 10000. AREA OF T.I. IS 11055 SQ. FT. NEW LIGHTING. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26832	18041-20000-00377	8841 N WILBUR AVE	91324	12	195B121   272	2784002021	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Issued	01/04/2018 12:00:00 AM	ADDRESS	34.2316	-118.54492	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 2507 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26833	17041-10000-18693	3421 W 6TH ST 1ST FLOOR	90020	10	135B197   993	5502021001	(T)(Q)RAS4-1	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM			PC Info Complete	06/05/2017 12:00:00 AM	ADDRESS	34.06373	-118.29613	Title 24 plan check.  Change of use from retail to coffee shop on 1st floor of existing commercial building.  Subpanel to remain existing with new lighting and receptacles.  Total area = 1,428 sq. ft.       Building permit #17016-10000-08495	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26834	15041-10000-28939	389 E TERMINAL WAY 3rd Flr	90731	15	015B205     7	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	33.74208	-118.2656	Energy plan check for new light, equipment and receptacle for a data center on the 3rd floor of main building; Total area is 645-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26835	18041-10000-22082	8500 W BEVERLY BLVD #719	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN EXISTING RETAIL SPACE IN A COVERED MALL. T-24 ENERGY ONLY. BUILDING PERMIT #18016-10000-18376	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26836	18041-20001-42446	11321 W COHASSET ST	91352	2	186B173   470	2315016030	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.20675	-118.3777	Plan check for design-build contractor plans.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26837	15041-10000-12088	1001 S OLIVE ST	90015	14	127-5A209 222	5139009016	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			04/22/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.04228	-118.25988	NEW FIRE ALARM SYSTEM >500 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26838	16041-10012-25972	200-300 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	REDUCTION IN SCOPE OF WORK. REDUCE AS NOTED ASI-005R1. REMOVAL OF CIRCUITS AND LIGHTING, T24 IN DELTA OPS AND LOCKER ROOM. PC ONLY - PERMIT STILL COVERED FROM MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26839	14041-20000-04746	671 S CORONADO ST	90057	1	133-5A201 157	5141008002	R4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Apartment			02/20/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.0598	-118.28202	T24 part 6 energy for 4 story apartment building in common area and main entry lobby. scope of work < 400a. all work will be interior.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26840	15041-20000-22270	20933 W HEMMINGWAY ST	91304	3	189B109   516	2109013015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.2145	-118.58989	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (48) modules, (1) combiner box, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26841	13041-10000-29830	1228 N SANBORN AVE	90029	13	145-5A203  35	5429012010	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.09492	-118.27868	PV1, ROOF-MOUNTED SOLAR INSTALLATION, TO INTERCONNECT WITH EXISTING 125A MAIN BUS SIZE. WORK DONE ON MICROINVERTER STANDARD PLAN WITH 17 MODULES (LG; LG-260S1C-G3) AND 17 MICROINVERTERS ENPHASE M215. 1 TOTAL STRING.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26842	15041-20000-20550	18947 W KILFINAN ST	91326	12	219B121    31	2820002005	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.29736	-118.54743	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac. System consists of (1) inverter, (34) modules, and (2) combiner boxes. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26843	12041-10000-27062	2340 W PICO BLVD	90006	1	129B197  1086	5056004021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			Verifications in Progress	03/12/2013 12:00:00 AM	ADDRESS	34.04707	-118.28767	PV2 - PLAN CHECK FOR NEW 5.640 KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26844	16041-20000-45041	6135 N VINELAND AVE	91606	2	177B173   584	2336036038	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.18223	-118.37055	TI and change of use from retail to massage parlor.  Building permit 16016-20000-29734.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26845	17041-20001-06991	16661 W CUMBRE VERDE CT	90272	11	138B121   197	4431033021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM			PC Approved	03/13/2017 12:00:00 AM	ADDRESS	34.07106	-118.55112	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12.6 kWac and consists of (2) inverters, (54) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26846	15041-10000-19119	12946 W HAGAR ST	91342	7	222B161   511	2525003050	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM			PC Info Complete	06/18/2015 12:00:00 AM	ADDRESS	34.30346	-118.41503	OPTIONAL GENERATOR  17KW TO A SFD.  PLAN CHECK REQUESTED BY APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26847	10041-20000-07812	8638 N WOODMAN AVE	91331	6	195B153  1235	2640019019	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00, 1199.00	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Finaled	07/11/2011 12:00:00 AM	ADDRESS	34.22748	-118.43355	installation of elecrical equipment, lighting and power for new autozone store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26848	17041-10000-42332	5971 W VENICE BLVD 2ND & 3RD-FLOORS	90034	10	126B173   912	5066003021	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	04/05/2018 12:00:00 AM		Issued	04/05/2018 12:00:00 AM	ADDRESS	34.03865	-118.37272	TENANT IMPROVEMENT: INTERIOR REMODEL ; FULL PLAN CHECK ON FLOORS 2 AND 3 OF EXISTING CLINICAL SPACE (MEDICAL OFFICE) NO HOSPITAL.NEW PANELBOARDS AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26849	13041-10002-08064	10459 W TUXFORD ST	91352	7	198B177   137	2544014003	A1-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	ADDRESS	34.23764	-118.35908	Change to approve set of plan. Remove outside light and class room building. (((((CONSTRUCTION OF NEW CLASSROOMS AND OUTDOOR LIGHTING. PC FOR T24 ENERGY ONLY. LOW ADDITIONAL LOAD. PWERMIT TO BE ISSUED BY PC STAFF ONLY.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26850	14041-10000-14633	8360 N MINUET PL	91402	6	192B153   573	2637020026	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.22324	-118.43316	PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLA ARRAY ON 1-STORY HOUSE. TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26851	19041-10000-14930	910 N HILL ST	90012	1	135A215   184	5414012013	C2-2	Central	Central City North	Historic Cultural North		2071.03	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.06495	-118.23827	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26852	19041-20000-41026	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26853	12041-10000-10665	23111 W CUMORAH CREST DR	91364	3	168B097   644	2074033012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.15419	-118.63039	Plan check for new roof mounted 5.886KW photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26854	12041-20000-09378	1947 N WESTRIDGE TER	90049	11	138B133   457	4492012020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	ADDRESS	34.07113	-118.5007	PV system for a single family dwelling. 6.75kW rooftop system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26855	19041-20000-43010	7418 N YARMOUTH AVE	91335	3	186B129   794	2120034008	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.20538	-118.51955	Plan check for PV roof mounted system install into existing PV system, addtion PV system size: 1.85KW with 5 PV Modules and 5 microinverters. Total existing and addtion PV system size: 4.17 KW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26856	17041-10002-07060	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	Supplemental for changes to approved set. Plans revisions are the addition of markings and notes pertaining to the installation of CI cables. Delta 5 changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26857	12041-10000-09902	630 S MASSELIN BLVD	90036	4	135B181   759	5508014037	R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			05/01/2012 12:00:00 AM			PC Info Complete	08/14/2012 12:00:00 AM	PIN	34.0637312	-118.35218585	UPGRADE THE EXISTING 168 UNIT PANELS AND INSTALL  A NEW WASHER/DRYER UNIT IN EACH ON THE 168 UNIT OF AN EXISTING 4 STORY APARTMENT BUILDING.  <<BLDG PERMIT # 12016-10000-07775)>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26858	17041-20001-05665	6201 N VAN NUYS BLVD	91401	6	178-5A151 361	2241013006	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Issued	09/11/2017 12:00:00 AM	ADDRESS	34.18278	-118.44897	08/31/2017 Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement to a restaurant. Total lighting area = 543 sq. ft.*****Previous Work Description*****NEW FIXTURES AND OUTLETS EXIT SIGNS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26859	18041-10000-42009	7540 WORLD WAY Delta-F/A	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	33.94052	-118.42863	"NEW FIRE ALARM SYSTEM IN THE ""DELTA MAITENANCE HANGER"" IN LAX."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26860	16041-10000-38465	11611 W SAN VICENTE BLVD #910	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	02/22/2023 12:00:00 AM	ADDRESS	34.0541	-118.46261	Plan check Title 24 only in existing space high rise Building T.I. Suite #910. Total area: 996 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26861	19041-20000-22554	9216 N TELFAIR AVE	91352	6	198B165   218	2629012010	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.23712	-118.39737	PLAN CHECK FOR ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6.04KW DC/6 KW AC. SCOPE OF WORK INCLUDES (20) CANADIAN SOLAR PV MODULES WITH P320 OPTIMIZERS AND A SE6000H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26862	17041-10000-33528	4407 S CENTRAL AVE	90011	9	112-5A209  88	5108028028	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.00366	-118.25677	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26863	19041-10000-30334	16403 W VENTURA BLVD Suite F	91436	5	168B137   331	2260009044	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	06/03/2020 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.15747	-118.49025	PC for T24 only, scope of work is a TI in an exisiting retail shop (Sees Candies), scope of work includes new lighting, controls, and new circuits. Total affected area is 986 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26864	18041-10001-42009	7540 WORLD WAY F/A-BEC	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	33.94052	-118.42863	"DELTA ""4"" CHANGES TO APPROVED PLANS FOR ADDITIONAL 8 DEVICES.<<<<NEW FIRE ALARM SYSTEM IN THE ""DELTA MAITENANCE HANGER"" IN LAX.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26865	13041-20001-02294	7855 N HAYVENHURST AVE	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	03/14/2013 12:00:00 AM	ADDRESS	34.21329	-118.49262	Changes to power. Plan check per customer's request.New lighting to an existing commercial space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26866	14041-20000-26180	19153 W COMMUNITY ST	91324	12	192B121   520	2784013015	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.22287	-118.5509	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(30) KYOCERA KD255GX MODULES(30) POWER OPTIMIZERS(1) SOLAR EDGE SE6000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26867	17041-20000-14446	1302 S LA BREA AVE	90019	10	129B181   842	5070001018	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.04983	-118.34395	Plan check for power and energy. Build out common areas (stairs, parking, etc.) for new 2-story commercial retail building over one level of subtarranean parking. 5,000A service. 107,978sqft indoor area, 30,644 outdoor area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26868	15041-20000-10698	4428 N DENSMORE AVE	91436	5	165B141   117	2283007013	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.15167	-118.47735	Plan check for PV1 roof mounted 10.92kW system with 2 inverter(ABB # PVI-6000-OUTD-UYS-Z-A, ABB #PVI-4.2-OUTD-S-US-Z-A) and 42 modules (kyocera # ku2606xpa) and 1 load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26869	17041-10001-16285	4260 N WHISPERING PINES CT	91316	5	165B125   251	2184040038	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2017 12:00:00 AM			PC Approved	05/30/2017 12:00:00 AM	ADDRESS	34.14793	-118.5286	05/30/2017 Changes to the approved set of drawings. The changes include the relocation of the inverter and AC disconnect  only on PV-2A.*** PV1 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER SOLAR EDGE 7.6KWAC AND (29) MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26870	15041-10001-08090	410 W 8TH ST	90014	14	127-5A209  75	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.04466	-118.25638	LOST original plan, new resubmit for PC only, plus changes on Delta-5.  Master Plan/Permit #15041-20000-08090  <<Plan check for power and Title-24 (energy).  Total area = 2,286 sq. ft.T.I. to new restaraunt.  Two new 225 A panels connected to existing service.  Lighting and recepticles. emergency lighting thorugh generator.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26871	13041-10001-33149	13156 W VAUGHN ST	91331	7	213B161   125	2524006027	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/08/2013 12:00:00 AM	PIN	34.28377072	-118.41914898	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26872	14041-10001-08939	734 W 124TH ST	90044	15	081B197   119	6117015002	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	33.91994	-118.2882	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26873	19041-20001-23088	1114 N WHITE KNOLL DR	90012	1	138B213   501	5406018048	RD1.5-1	Central	Central City North	Historic Cultural North	YES	1977.00	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM			PC Approved	11/04/2019 12:00:00 AM	ADDRESS	34.0706	-118.24702	Revisions to approved set of plans.  Change of conduit size on SLD. (((1200A 240/120V 1ph-3w service for small lot subdivision.  Plan check for power)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26874	13041-10001-36310	217 N AVENUE 49	90042	1	150A225   204	5467029025	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1851.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/28/2014 12:00:00 AM	ADDRESS	34.10513	-118.20443	Expedited RSES plan check per applicant request.{{PV1, Install 4 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (16) Modules: Trina Solar TSM-250PA05.18.(16) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26875	18041-10000-35107	9049 N WOODMAN AVE	91331	6	195B153   158	2639033013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.23405	-118.43978	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26876	14041-20000-10285	13033 W VENTURA BLVD A	91604	2	165B161   943	2375020016	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.14585	-118.41713	pc for t24 energy only. changes to lighting in storage room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26877	14041-20000-34601	12301 N EL ORO WAY	91344	12	219B133   604	2606005043	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.29411	-118.50481	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 17 MODULES. SYSTEM USES POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26878	16041-10004-09173	501 W EL SEGUNDO BLVD	90248	15	081B201   259	6132002024	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	33.91659	-118.28337	Changes to approved set of plans. Removing IG circuits, changes clouded under delta 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26879	19041-10000-05036	4252 S CRENSHAW BLVD	90008	10	114B185   958	5024017007	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.00668	-118.33443	PC FOR FA. SCOPE OF WORK PROPOSED 4 STORY, TYPE VA 111 UNIT APARTMENT. THIS IS A TOC PROJECT  (TIER 4 PER PLANNING) FACTORY BUILT STATE APPROVED HOUSING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26880	18041-10000-13119	3201 S LA CIENEGA BLVD Suite B	90016	10	123B173  1684	4205035014	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.02965	-118.37211	PC for T24 only for new lighting for renovations to office Mezzanine level. Intalling new lights and receptacles. Total area 658sqft. B# 18016-30000-06822.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26881	18041-10000-12554	12727 W SHERMAN WAY	91605	2	183B161    11	2324004004	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	03/03/2023 12:00:00 AM	ADDRESS	34.20137	-118.41091	New fire alarm system being installed in a multi tenant space, shopping centers. Scope of work includes new fire alarm panel and FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26882	18041-20000-25653	20716 W BEECH CIR #297	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.29274	-118.58488	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26883	14041-10000-14109	12912 W SHERMAN WAY	91605	2	183B161    47	2327018072	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.20103	-118.41414	CHANGE OF USE FROM RETAIL TO BEAUTY NAIL SALON,PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26884	15041-20000-34433	6303 N OWENSMOUTH AVE 1st Floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.18474	-118.60182	Plan check for Title 24 only. Project site is a portion of the 1st floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 3,575 sq. ft.Note: Building application has been filed under 15016-10000-19763	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26885	18041-20000-05264	7716-7724 N BURNET AVE	91405	6	189B145   656	2209037055	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.21073	-118.46279	Service upgrade to an existing commercial building 800A 240/120V 3ph-4w delta.  Plan check for power.  New panels with no circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26886	18041-20000-04239	17259 W DEVONSHIRE ST	91325	12	204B133   166	2695015001	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.25773	-118.51007	PV1.  Install roof-mounted PV system sized 15.2kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26887	13041-10000-23101	181 S ALTA VISTA BLVD	90036	5	138B181  1240	5512021001	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.07125	-118.34755	PV1. ROOF MOUNTED.  TRANSFORMER (negatively grounded). SYSTEM SIZE: 6.48 KW. 24 MODULES. SMA SB6000. PLANCHECKER CHECK THE FEES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26888	14041-20000-34044	16212 W SHADOW MOUNTAIN DR	90272	11	132B121   395	4420039009	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.05627	-118.53894	PV1 system roof mounted with the system size: 12.7kW and 53 modules with 1 inverter and 1 load center.Permit Fee is $0.00 due to senate Bill 1222 from 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26889	14041-10000-23776	12510 W FIELDING CIR	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	33.97839	-118.4121	PLAN CHECK FOR FIRE ALARM SYSTEM FOR APARTMENT COMPLEX WITH MULTIPLE BUILDING WITH MULTIPLE ADDRESSES. THIS IS BUILDING 7 OF 7. ALL BUILDING UNDER ONE SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26890	19041-10000-06947	9608 N VAN NUYS BLVD	91402	6	201B149   655	2644025033	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.24472	-118.45003	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26891	19041-10000-31550	762-764 S STANFORD AVE	90021	14	126A213   709	5146029049	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	08/18/2020 12:00:00 AM		Permit Finaled	08/18/2021 12:00:00 AM	ADDRESS	34.03741	-118.24587	POWER AND ENERGY PLAN CHECK FOR A TI OF AN EXISTING WAREHOUSE (FOR STORAGE ONLY). SCOPE INCLUDES NEW 800A SERVICE, EQUIPMENT, LIGHTING, RECEPTACLES AD CONTROLS. TOTAL AFFECTED AREA IS 9,456 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26892	17041-10000-06566	14512 W VENTURA BLVD	91403	4	166-5A151 142	2276001002	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.15083	-118.44921	NEW ICE CREAM SHOP. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26893	16041-10000-22093	6841 S VICTORIA AVE	90043	8	102B185   695	4006023011	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	33.97582	-118.3325	PV1, rooftop solar installation on SFD, 3.8 kW AC    (14)Modules HiS-S260RG     (1) Inverter-enphase SE3800A-US    and (14) Solaredge P300 Power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26894	17041-10000-21114	1149 S HILL ST STE 900	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.03926	-118.26099	"SUITE 900 - 3572 SF  INTERIOR TENANT IMPROVEMENT TO INCLUDE NEW INTERIOR NON BEARING PARTITIONS, CEILING AND FINISHES W/ FREESTANDING 8' 0"" HEIGHT INTERIOR WALL"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26895	14041-20000-02949	19547 W SAN JOSE ST	91326	12	207B117   434	2708005021	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.26082	-118.55949	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26896	12041-20001-22373	633 S LA BREA AVE	90036	4	135B181   737	5508007021	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM			PC Info Complete	07/08/2013 12:00:00 AM	ADDRESS	34.06387	-118.34429	Modification to approved set for T.I., new circuits, loads, change to lighting.      <<<<NOT CHECKED FOR OSHPD3.  2 STORY ADDITION TO EXISTING 2- STORY BUILDING,  CONVERT (E) TAKE OUT RESTAURANT AND OFFICE TO (N) MEDICAL OFFICE  AND SHELL ONLY GENERAL OFFICE SEPARATE TENANTS.  SITE IS IN A METHANE ZONE.  FULL PLAN CHECK REQUIRED.  >>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26897	13041-10000-03587	7906 S BREEN AVE	90045	11	099B173   635	4127022004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	33.96494	-118.37772	PV1 3.43kw MICRO INVERTER SINGLE STORY HOUSE. [MIRCRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26898	12041-10001-30779	"12746 W JEFFERSON BLVD ""4"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	change to approved set, changes include adding circuits, removing and adding lighting, and relocate some electrical devices.(((Plan check power and energy for Building 4. Five story parking garage building with common subterranean parking to Building 1, 2, 3, and 4. Service supply from Building 3. Site located in methane zone. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26899	12041-20000-29076	127 S SAN VICENTE BLVD Bulletin-#215-TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			Corrections Issued	12/04/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Plan check for REVISION Delta # 215-TI Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26900	16041-10000-12198	14440 W BURBANK BLVD	91401	4	174B149   910	2245007027	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1285.00	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.17189	-118.44778	Energy plan check for super market T.I . Scope include new lighting and receptacles. Total area is 570 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26901	17041-10000-18912	6110 N VARIEL AVE	91367	3	177B105    51	2149005034	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/08/2021 12:00:00 AM	ADDRESS	34.18136	-118.59257	Remove and replace FACP in existing fire alarm system.  Add one new smoke detector and pull station.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26902	16041-10000-18763	2159 E BAY ST Build. B	90021	14	123A217   424	5166001002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.03156	-118.22794	PC for Energy only, T-24.  Tenant improvement of existing office building. Install new lightings and controlled receptacles.  Total area: 1,060 sq.ft. New connected load < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26903	10041-20000-04105	7800 N WOODLEY AVE	91406	6	189B141   192	2206008020	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			03/08/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.21161	-118.48344	Plan check power and energy existing warehouse (Munchkin).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26904	16041-10000-30346	2300 W VENICE BLVD	90019	10	126B193  1425	5073012032	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.04335	-118.30936	T-24, PC FOR POWER AND ENERGY ONLY. TI TO AN EXISTING RESTUARANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1879 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26905	19041-10000-45537	602 N KENTER AVE	90049	11	138B137   616	4494020019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.07037	-118.48838	$0 fee due to AB1414 [EPLAN] NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 9.0KW DC/ 10KW AC WITH A CENTRAL INVERTER OF 10 KW (SE10000H-US),  30 MODULES (SLA-M300), 30 POWER OPTIMIZERS (P320).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26906	15041-10003-08090	410 W 8TH ST	90014	14	127-5A209  75	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			PC Info Complete	04/03/2018 12:00:00 AM	ADDRESS	34.04466	-118.25638	PC for a lost set of plans. In addition, changes are made to title 24 calculations and  revisions to floor plans. Plan check for power and Title-24 (energy).  Total area = 2,576 sq. ft. Note: Some permit fees are paid under PCIS#15041-20000-08090	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26907	16041-10000-39925	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	Installation of new fire alarm system in existing 12 story  hotel building.  Total system size = 1,557 devices + 2 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26908	16041-10000-19933	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC FOR ENERGY FOR FACILITY IMPROVEMENT FOR TERMINAL 3 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUSING OPERATION, OFFICE RENOVATION, AND IMPROVED FINISHES AND MILLWORKTHE APPLICATION 16041-10000-11825 IS RELATED TO CONNECTED LOAD OTHER THAN THE SCOPE OF THE WORK FOR THIS PROJECT.BUILDING APPLICATION IS 16016-1000-11866. TOTAL AREA 4991 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26909	16041-20000-33327	13801 W VENTURA BLVD	91423	4	165B153   543	2271017005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.14852	-118.43319	PV2.  Install roof mounted grid-tied PV system sized 22 kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26910	12041-20000-22340	15231 W LA CRUZ DR	90272	11	129B125   771	4412002018	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	34.04579	-118.52507	energy plan check retail bakery.  Load is less than 400 amps, no emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26911	15041-20000-09421	17969 W SANTA RITA ST	91316	5	171B129   278	2182001015	R1-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.16354	-118.52444	PV1. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.2 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26912	17041-10003-15998	15031 W RINALDI ST	91345	7	213B145    64	2664022028	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.27918	-118.46029	DELTA 18 CHANGES TO APPROVED SET. ADDITION OF RECEPTACLES TO LOUNGE AREA AND OFFICE SPACE. ALL PANELS AND CALCULATONS ARE UPDATED TO REFLECT THE NEW CONNECTED LOAD. (((PLAN CHECK FOR POWER AND ENERGY FOR TI (NEW ADMIN OFFICE). SCOPE INCLUDES ADDITION OF LOAD TO EXISTING DISTRIBUTION EQUIPMENT(30 DAY METER READING ARE PROVIDED ON SINGLE LINE DIAGRAM). TOTAL CONNECTED LOAD >400A. TOTAL SQ FT. 7316.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26913	19041-30000-27051	3022 N COOLIDGE AVE	90039	13	150B213   886	5442022020	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Issued	07/16/2019 12:00:00 AM				P.C FOR TITLE 24 ONLY OUTDOOR SITE LIGHTING. TOTAL AFFECTED AREA 2032 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26914	14041-20000-25765	15003 W VICTORY BLVD	91411	6	180B145   775	2235021041	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.18681	-118.45977	New fire alarm system for 17-unit, 2-story apartment building.  FACP, annunciator, and 59 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26915	13041-10000-30569	1800 N ARGYLE AVE	90028	13	150A189   301	5546033015	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.10384	-118.32506	PLAN CHECK FOR POWER AND ENERGY. 16 STORY HIGH RISE HOTEL WITH 200 ROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26916	18041-20000-05547	13062 W TERRA BELLA ST	91331	7	204B161    72	2623002013	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Issued	02/21/2018 12:00:00 AM	ADDRESS	34.25866	-118.41761	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac/5.61 kWdc and consists of (1) inverter and (17) modules. MSP is center-fed. Submitted per applicant request.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26917	14041-20000-09027	13239 W BLOOMFIELD ST	91423	4	165B157   416	2375001076	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.14943	-118.42121	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.2KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26918	17041-20001-36351	17734 W BALTAR ST	91335	12	189B129   300	2101005027	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.21675	-118.52039	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26919	13041-10000-33547	17501 S FIGUEROA ST	90248	15	063B201    64	7339007014	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	33.87169	-118.28187	TITLE 24.Remove HID light fixtures and replace with new fluorescent fixtures in a commercial building.AREA 4815	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26920	15041-20000-40757	20947 S DALTON AVE	90501	15	051B193   134	7349005011	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	33.83846	-118.30291	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER. SYSTEM SIZE: 1.96 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26921	18041-10000-44388	21240 W BURBANK BLVD B30	91367	3	174B105    40	2149016026	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.17307	-118.59314	TI FOR A WORKSHOP SPACE. SCOPE INCLUDES 2 NEW PANELS, LIGHTING AND RECEPTOICALS. TOTAL AFFECTED AREA IS 1823 SQ.FT. T-24 ONLYB# 18016-10000-34566	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26922	12041-10001-29865	8950 N WOODLEY AVE	91343	12	195B141   185	2672002002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.23343	-118.48487	(((RELOCATION OF MAIN SERVICE AND SOLAR DISCONNECT)))5.8 KW ROOF MOUNTED PV FOR A SINGLE FAMILY. (X-FORMERLESS INV)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26923	19041-10000-29128	13005 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	34.14571	-118.41627	POWER PLAN CHECK FOR COFFEE SHOP- APPROVAL FOR TITLE 24 AND PERMIT ARE ON ORIGINAL APPLICATION 18041-10000-36496; ADDRESS CHANGE IS ON APPLICATION 18941-10001-36496.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26924	11041-10000-09328	3502 S WATT WAY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.02207	-118.28645	T.I.  REMODEL OF ONE ROOM.  CREATING A TELECONFERENCE ROOM.  TITEL 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26925	19041-20000-24481	15553 N SORBONNE ST	91342	7	228B141   208	2603020009	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	09/28/2019 12:00:00 AM	ADDRESS	34.32148	-118.47498	Plan check for Batter Energy storage system installing into existing PV System. Energy Storage System: 13.5KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26926	18041-10000-04278	5239 N VAN NUYS BLVD	91401	4	172-5A151 198	2249006045	QC2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1288.02	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.16595	-118.44901	PC for T24 only for replacement of metal halide fixtures with new LED fixtures in indoor and outdoor areas. Total area indoor=4400sqft and outdoor=61050sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26927	16041-10000-03814	6314 W HOLLYWOOD BLVD	90028	13	148-5A187 367	5546009***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.1014	-118.32715	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO CAFE/ BAKERY WITH DINING. SCOPE INCLUDES NEW LIGHTING AND THREE NEW PANELS. TOTAL AFFECTED AREA IS 1095 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26928	17041-20001-28389	18801 W PASADERO DR	91356	3	165B121   330	2177020011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM			Reviewed by Supervisor	08/23/2017 12:00:00 AM	ADDRESS	34.14847	-118.54338	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (57) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26929	18041-20000-32871	22641 W OXNARD ST	91367	3	177B097   482	2039017023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Issued	09/04/2018 12:00:00 AM	ADDRESS	34.17931	-118.62026	Note: $0.00 permit fee due to CA Senate Bill 1222.pv1install roof mounted pv system sized 30.4KW AC interconnected with msp.(93) sc 320 Watts modules(3) solaredge inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26930	15041-20000-35841	14571 W GREENLEAF ST	91403	4	166-5A151 273	2276015019	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.14867	-118.45158	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 10.79KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26931	17041-10000-40321	2651 S HOBART BLVD	90018	8	123B193   848	5053011037	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Public Safety Only			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.0311	-118.30806	NEW FIRE WARNING SYSTEM FOR  9 UNITS 2-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26932	19041-10001-25350	23332 W HAMLIN ST	91307	12	180B093   596	2036014006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.18887	-118.63571	Expedite per applicant's request.(((Plan check for a PV1 roofmounted 10.1KW system.  Scope includes (1) subpanel, (4) ckts, and (28) AC modules interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26933	18041-10000-43795	10250 W SANTA MONICA BLVD #9255	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	TI IN AN EXISTING COMMERCIAL AREA  IN SUITE # 9255. REPLACING EXISTING LIGHTS. TITLE 24 ENERGY ONLY.  SCOPE OF WORK INCLUDES 300 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26934	16041-10000-16300	2414 W LAS FLORES DR	90041	14	163-5A221 119	5682017017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Expired	06/12/2018 12:00:00 AM	ADDRESS	34.14286	-118.21948	PV1 INSTALL NEW 4240 W CDC ROOF-MOUNTED SOLAR ARRAY(16) MODULES: CANADIAN SOLAR CS6P-265P(1) INVERTER: ABB PVI-3.6-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26935	17041-10000-42424	14128 W DICKENS ST	91423	4	165B153   622	2266013***	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.14808	-118.44073	PC FOR ROOF MOUNTED PV ON A CONDO WITH SHARED ROOF. SYSTEM SIZE IS 7.56KWACSCOPE INCLUDES 21 AC MODULES WITH LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26936	15041-10000-19510	3456 S MOTOR AVE SUITE F	90034	5	120B161   364	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.02698	-118.40853	Full plan check for a first time tenant, gym studio, build out. Main scope includes  (20) circuits, (1) equipment, and T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26937	19041-20000-24216	6839 N GEYSER AVE pv1	91335	3	183B121   973	2126027007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.195	-118.54272	pv1install roof mounted pv system sized 3.8KW AC interconnetced with msp.this is plan check only.  fees paid under application number 19041-90000-14357	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26938	17041-10000-08014	515 S FLOWER ST 50TH FLR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	RENOVATION OF 50TH FLOOR ELEVATOR LOBBY AND RESTROOM UPGRADES. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26939	18041-10000-24911	8985 W VENICE BLVD SPCE  C1B	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.02733	-118.39241	PC FOR ENERGY ONLY, TENANT IMPROVEMENT FOR EXISTING RESTAURANT SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1312.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26940	14041-20000-28523	13319 W BERG ST	91342	7	228B157    99	2511012028	RA-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.3249	-118.4223	install roof mounted pv system sized 3.4kw interconnected with msp.(16) sunmodule sw275 modules(16) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26941	12041-10000-08954	310 S BERENDO ST	90020	4	135B197   227	5502007002	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	34.06859	-118.29397	T.I. to an existing dollar store, Load is 190.8A and occupancy load is less than 99, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26942	19041-20000-20877	12512 N ARISTO PL	91344	12	219B129   332	2608011036	RE11-1-H, RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.29761	-118.51504	Plan check for PV roof mounted system, PV system size: 11.88KW DC, 10.94KW AC CEC with 36 PV Modules and 36 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26943	13041-10000-35810	200 N SPRING ST 23RD FL	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.05405	-118.24317	TENANT IMPROVEMENT IN OFFICES ON 23RD FLPLAN CHK IS FOR TITLE 24 AND 2EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26944	19041-20000-41544	20708 W BLUEBIRD CT	91326	12	219B109   502	2701108005	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.29724	-118.58472	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.725 KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26945	15041-10000-38088	1050 W PACIFIC COAST HWY 2ND FLR	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Info Complete	12/04/2015 12:00:00 AM	ADDRESS	33.79072	-118.29449	PC FOR T24 ENERGY ONLY. LIGHTING ALTERATIONS GREATER THAN 40 LUMINAIRES. NO OTHER WORK BEING DONE. WORK DONE ON SECOND FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26946	17041-20000-35662	114 S OXFORD AVE 1-35	90004	10	138B193  1029	5517009034	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Apartment			10/04/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.07317	-118.30776	pv2install roof mounted pv system sized 13.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26947	16041-10000-30228	1117 1/2 S HOPE ST	90015	14	127-5A207 262	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.04196	-118.26367	PC for energy only to an existing building. Change of use from retail to beauty salon. Installing new lighting only. Scope of work is being done in two small offices within the tenant space. Total sqft = 1001.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26948	11041-10000-04366	7260 N OWENSMOUTH AVE	91303	3	186B105   879	2111019903	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.10	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.20274	-118.60137	FIRE ALARM FOR SINGLE STORY CHILD DEVELOPEMENT INSTITUTE.  PC OVER THE COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26949	19041-10000-52060	906 W SANDWOOD PL	90731	15	027B197    18	7442004010	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	33.76595	-118.29791	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.76KWdc / 4.64KWac.(16)MODULES-POWERXT-360R-PD(16)MICROINVERTERS-ENPHASE IQ7PLUS-72-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26950	15041-20001-06435	10161 W VALLEY SPRING LANE	91602	4	165B181   452	2424035006	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	34.14691	-118.35223	Expedited per applicant request.****Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (48) modules, (1) inverter, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26951	19041-20001-19951	112 N JUNE ST	90004	4	138B185   211	5515003007	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.07442	-118.33415	Expedited plan check fee.PV1.  Install 12.73 kW DC / 10.82 kW AC roof mounted grid tied PV system.  (38) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26952	19041-10000-34143	8484 N FARRALONE AVE	91304	12	192B101   239	2010018004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.22446	-118.61093	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 28 MODULES WITH P400 OPTIMIZERS AND 2 ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26953	14041-20001-10481	4807 W MELROSE AVE	90029	13	141B193   515	5535029033	[Q]C1-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.08367	-118.30538	Plan check for energy only. New lighting in existing coin laundry. Inspector requested Title 24 plan check. [[[INSTALL (14) NEW LIGHTS IN (E) LOCATION. COMPLY W/ DEPT ORDER DATED 4/09/14. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. **INVESTIGATION FEE INCLUDED** 1 OF 3 W/ #14044-10000-03655.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26954	14041-20001-04616	22443 W HAYNES ST	91307	12	180B101   425	2038033017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.18981	-118.61625	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26955	18041-20001-09807	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM			PC Approved	04/27/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	04-27-2018 Changes to an approved set of plans. Changes include added scope of work, new lighting in storage area 1st floor. 463 sq ft has been added. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26956	15041-20000-06580	1018 S WESTWOOD BLVD	90024	5	132B153    28	4363020007	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.06199	-118.44516	Plan check for power and energy for T.I of the building with 800A service. Complete renovation for 3 floorss commercial buildingCOMMERCIAL T.I. TO INCLUDE SEISMIC STRUCTURAL RETROFIT OF ENTIRE STRUCURE (URM BLDG) NEW STOREFRONT.  ELEVATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26957	16041-30000-18939	17151 W NANETTE ST	91344	12	222B133   588	2602018024	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.30183	-118.50618	Plan check for a PV1 roof-mounted PV system. System size is 9.2 kWac and consists of (2) inverters, (43) modules, (1) load center, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26958	15041-10000-23170	12750 W RAYMER ST #3	91605	2	186B161   550	2324004001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.20367	-118.40986	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3260 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26959	18041-10000-23543	355 S GRAND AVE #2050	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PC FOR OFFICE TI ON THE 20TH FLOOR FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS.TOTAL CONNECTED 3845 SQ.FT.  B# 17016-20000-36398	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26960	18041-20000-44311	11110 W HARTSOOK ST	91601	2	171B173   789	2353007013	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	10/30/2020 12:00:00 AM	ADDRESS	34.16365	-118.37284	PLAN CHECK FIRE ALARM FOR 5 STORY APARTMENT BUILDING WITH 152 DEVICES, 1 FIRE ALARM PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26961	17041-10000-35895	864 S ROBERTSON BLVD	90035	5	132B169   100	4333015025	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM			PC Approved	10/05/2017 12:00:00 AM	ADDRESS	34.06106	-118.38339	Energy plan check  for an  existing commercial building. Scope includes new lighting and  new controls to existing panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26962	14041-20002-08886	4419 N BABCOCK AVE	91604	2	165B161   230	2362027038	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.15108	-118.40645	MODIFICATION OF APPROVED SET - ADDITION OF A SINGLE AC DISCONNECT ONLYFEE IS $0.00 DUE TO SENATE BILL 1222[[[PV1Install 7kW roof mounted PV system, interconnect with main service panel.(1) Transformerless inverter - SolarEdge Se6000A with power optimizers.(28) Renesola JC250M-24/BB.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26963	16041-10000-32041	948 1/2 W 81ST ST	90044	8	099B197  1055	6032005011	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	33.96534	-118.29071	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 1.505KWac.(7)MODULES-HYUNDAI HIS-M215-2LL-S2X-IG(7)MICROINVERTER-ENPHASE M215-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26964	10041-10001-00533	1037 S BROXTON AVE	90024	5	132B149    45	4363024008	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.06174	-118.44667	REVISIONS TO APPROVED/PERMITTED SET OF PLANS: AVAILABLE SHORT CIRCUIT AT POINT OF SERVICE IS 22KA NOT 42KA ; ADDED SUBPANEL D1 WITH NEW CIRCUITS ; SERIES RATED PANELBOARDS AT 22KA NOT 42 KA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26965	11041-20000-20946	5550 W WILSHIRE BLVD #101D	90036	4	132B181  1299	5089005***	[Q]C2-1-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			09/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.06206	-118.34979	Plan check power and energy first time tenant (unit #101D) Five Guys Burger Restaurant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26966	19041-10000-07987	1661 W 240TH ST	90710	15	042B193   713	7439007033	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	04/20/2020 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	33.80741	-118.3065	Power plan check for a new 1000A 480/277 3 phase 4 wire Service/distribution board. Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application #19041-10000-08009	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26967	13041-20000-13091	7832 N ALABAMA AVE 3 - 6-10 - 13	91304	3	189B105   400	2110006026	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.21279	-118.59926	Plan check for energy only. Empty tenant spaces. Fire damage repair. Units 3,4,5,6,10,11,12,13.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26968	13041-10000-29465	11636 W BARRINGTON CT	90049	11	135B145   589	4401006013	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.0649	-118.46925	879 sf tenant improvement for new juice bar tenant. Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26969	17041-10000-36387	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Public Safety Only			10/10/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	NEW FIRE WARNING SYSTEM   FOR A NEW 7 STORY MIXED USE BLDG.:  169 UNIT APARTMENT WITH RETAIL AND PARKING. (536) devices, (1) FA panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26970	17041-10000-25045	9433 N RESEDA BLVD	91324	12	198B125   125	2763035003	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.242	-118.53628	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AREA IS 18600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26971	13041-10005-35652	1455 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM			Reviewed by Supervisor	04/13/2015 12:00:00 AM	ADDRESS	34.09728	-118.31598	(((4/2/2015- CHANGES MADE TO APPROVED SET: REVISING SOME CONDUCTOR, CONDUIT, AND OCPD SIZES. ALL CHANGES HAVE BEEN CLOUDED WITH A DELTA 3. APPLICANT WILL BRING APPROVED SET. )))NEW 7  ELEVATED LEVELS AND 2 BELOW GRADE PARKING STRUCTURE PLAN CHECK. PLAN CHECK FOR POWER AND ENERGY. NEW 2000A UNDERGROUND, 480/277V,3PH,4W. PROJECTED LIGHTING AREA IN SCOPE OF WORK IS APPROX. 581,525 SQ FT(INDOOR CONDITION/UNCONDITIONED + OUTDOOR ). 600A EMERGENCY DISTRIBUTION BOARD VIA 400A ATS, FED FROM 350kW/486 KVA EMERGENCY STANDBY DIESEL GENERATOR.building permit: 13010-10000-04219	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26972	10041-10000-03160	1251 E OLYMPIC BLVD	90021	14	123A213    47	5146017010	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	02/23/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.03249	-118.24443	change of use from retail to take-out restaurantplan chkis for title24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26973	18041-30000-14366	1555 S CARMELINA AVE	90025	11	123B145    70	4267029015	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.03681	-118.46419	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26974	15041-10000-21070	9784 W DRAKE LANE	90210	5	156B157   286	4385010013	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.1233	-118.42598	PV1 10KW rooof-mounted system with (40) Kyocera KD260 modules, and (1) Solaredge SE10000A-US inverter interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26975	14041-20000-24886	7014 S HOOVER ST UNIT 4	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 4.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26976	12041-20000-14327	5311 S RUTHELEN ST	90062	8	108B193   440	5005020011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Apartment			06/20/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	33.99384	-118.31272	New roof mounted P.V. system (5.9 KWdc).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26977	11041-10000-24474	942 E LAKE ST BLDG 4-1	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.00071	-118.46121	Lincoln Place Apartment Building Project.  New 2-story apt. building with 7 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26978	19041-20000-03268	11150 W OLYMPIC BLVD STE 1170-1180	90064	5	126B153   956	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.03956	-118.43857	Plan check for Title 24 only in existing space office space Tenant Improvement suites 1170 and 1180. Total area: 3447 sq ft. B#18016-10000-36434	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26979	18041-20000-29647	11755 W WILSHIRE BLVD 1ST FLOOR	90025	11	129B145   683	4265010192	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for Title 24 only in existing high-rise building restroom remodel. Total area: 395 sq ft. B#18016-10000-13017	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26980	19041-10000-28278	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/03/2020 12:00:00 AM	ADDRESS	34.16326	-118.37388	TENANT IMPROVEMENT TO A NEW GROCERY STORE. FULL PLAN CHECK FOR POWER AND ENERGY. INSTALLING NEW LIGHTS AND LOADS > 400 AMPS. TOTAL AREA: 25,713 SQR FT.BULDING PERMIT: 18016-10000-27289	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26981	14041-20000-02178	8445 N OAKDALE AVE	91306	3	192B113   295	2782010004	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.22341	-118.56682	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26982	14041-20000-12430	6223 E OAK CREST WAY	90042	14	157-5A231 212	5483017042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.12576	-118.18366	PV1Installation of roof mounted solar array on SFD. System size: 3kW(1) SolarEdge SE3800A-US transformerless inverter(12) Renesola JC250M-24/BB pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26983	16041-10000-34391	13274 W FIJI WAY #400	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	33.97902	-118.43558	Plan check for Title 24 only in existing office space 4th FL. Total area: 8,861  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26984	19041-10000-36786	17950 W PARTHENIA ST	91325	12	195B129   429	2787001019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.22845	-118.52472	$0 fee due to AB1414 [E-PLAN] Plan check only.  Delta 3,4 and 5: Field correction were issued to show the loads in the ATS to match the plans. Item (F) has been updated to match what is out on the field. Changes also include updating the available fault current to 10KAIC on a 400A service per DWP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26985	18041-20000-18502	14842 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.29469	-118.4545	PV1.  Install 3.78 kW roof mounted grid tied PV system.  (12) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26986	14041-10000-09517	549 S MORENO AVE	90049	11	129B137   606	4264004004	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	34.04641	-118.48747	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 10.0KWAC. THESE WERE CHANGES MADE TO APPROVED SET HOWEVER CHANGES ARE >50%. ORIGINAL APPLICATION#: 13041-10000-24969.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
26987	13041-20000-10994	7955 N LAUREL CANYON BLVD	91605	2	189B165   460	2309026018	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM			Reviewed by Supervisor	06/25/2013 12:00:00 AM	ADDRESS	34.21528	-118.39671	ti. build out for tenent A and core and shell for tenant B and tenant C. new tenants for retail use. pc for power and energy. totoal area 14570 sq ft. new 600A rated equipment connected to existing 1200A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26988	19041-20000-31130	13140 W ADDISON ST	91423	4	171B157  1111	2358009025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.16112	-118.41949	INSTALL (2) NEW TESLA ENERGY STORAGE BATTERY ON EXISTING PV1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26989	16041-10000-09142	2245 W YOSEMITE DR	90041	14	160-5A221  43	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.13556	-118.21671	INSTALLATION OF A NEW FIRE ALARM SYSTEM WITH 48 FA DEVICES AND ONE FA PANEL AND ONE COMMUNICATION PANEL ON SPROUT MARKET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26990	14041-20000-08875	24849 S SEAGROVE AVE	90744	15	039B209   262	7404028029	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	33.80043	-118.25981	pv1. install 3kw roof mounted pv system, interconnect with main service panel.(1) transformer-less inverter with power optimizers; solar edge model se3800(12) modules renesola jc250m	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
26991	10041-10000-25610	11925 W KLING ST	91607	2	168B165   625	2355014044	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	12/27/2010 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.15592	-118.39292	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26992	17041-10000-31790	555 S FLOWER ST 32ND FLR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.05048	-118.25755	OFFICE TI ON 32nd FLOOR. PC FOR T24 ENERGY ONLY.  SCOPE OF WORK INCLUDES THE REPLACEMENT OF LIGHTING TO LED AND CHANGE OF A SPACE TO OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26993	15041-10000-15643	8725 S CROCKER ST	90003	9	096A205    86	6041017006	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	33.95835	-118.26823	Retrofit of existing lights to LED fixtures.  Title 24 Part 6 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26994	17041-10000-04116	310 N CARMELINA AVE	90049	11	135B141   814	4405003001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES  (STANDARD ST)	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2017 12:00:00 AM			Corrections Issued	07/14/2017 12:00:00 AM	ADDRESS	34.06215	-118.48478	NEW SFD WITH ATTACHED GARAGE. PC FOR POWER AND RESIDENTIAL ENERGY STANDARDS. PC IN ACCORDANCE WITH 2014 STANDARDS DUE TO BUILDING SUBMITTAL. THIS APPLICATION IS PLAN CHECK ONLY. COMBO PERMIT AND ELECTRICAL FEES ALREADY ISSUED UNDER BUILDING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26995	18041-10000-10607	19310 W BUSINESS CENTER DR	91324	12	195B117    82	2783025059	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.2308	-118.55445	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
26996	18041-10000-41965	6600 N TOPANGA CANYON BLVD # 1034	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI IN AN EXISTING COMMERCIALSPACE IN SUITE #1034. T-24 ENERGY ONLY.   BILDING PERMIT: 18016-10000-35514IF FIRST TIME TENANT => COMPLETE PLAN CHECK WILL BE REQUIRED, SUBJECT TO FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26997	18041-10000-15173	3301 E 14TH ST	90023	14	118-5A225 337	5190033006	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.01727	-118.20835	REMOVE EXISTING HID FIXTURES AND REPLACE THEM WITH NEW LED FIXTURES. TITLE 24-ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
26998	14041-10000-23758	2929 W LEEWARD AVE 1-125	90005	1	132B197   273	5077016020	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			08/29/2014 12:00:00 AM			Reviewed by Supervisor	11/05/2014 12:00:00 AM	ADDRESS	34.05886	-118.28755	Plan check for power and lighting.  New 80 unit 5 story condo.  5 typical units, new 3000 A service.Building application #: 14010-10000-01634	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
26999	12041-20000-29259	2923 E 11TH ST	90023	14	120A221   184	5170025011	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.02144	-118.21536	PERMIT FOR NEW SERVICE, PANEL, BRANCH CIRCUITS AND NON DWELLING POWER EQUIPMENT. INSTALLATION DOES NOT EXCEED 400AMPS. Plan check for energy and emergency lighting. Single story warehouse. 4851 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27000	19041-30000-12836	831 N CROFT AVE	90069	5	141B173   100	5529003028	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	05/27/2021 12:00:00 AM	ADDRESS	34.08622	-118.37444	Plan check for a fire alarm system for a 4-story, 16-unit apartment building. System consists of (1) FACP, (1) annunciator, and (66) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27001	12041-10000-14060	14441 W BURBANK BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM			PC Approved	06/18/2012 12:00:00 AM	ADDRESS	34.17231	-118.44804	remodeling of existing  sandwich shop-less than 100 occupantsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27002	14041-20000-02386	5444 N YOLANDA AVE	91356	3	174B121   791	2161015001	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.17002	-118.54025	BEAUTY SALON. PC FOR T24 ENERGY ONLY. PER APPLICANT EXISTING 600A SERVICE. NEW LIGHTING. LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27003	18041-20001-18713	320 S LA BREA AVE	90036	4	135B181   238	5507008023	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.06822	-118.34383	07-12-2018 Changes to an approved set of plans. Changes include replace lighting fixture T1 to R3 in the dining area. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27004	19041-20000-32311	6080 W CENTER DR 4th floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	T24 PLAN CHECK FOR EXISTING HIGH RISE 4TH FLOOR RESTROOM. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 540 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27005	16041-10000-24431	915 W WILSHIRE BLVD #2200	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Issued	07/12/2016 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI on (E) office space on the 22nd floor.  Install new lights and receptacles.  Total area affected : 9,431 sq. ft. PC for T-24 only.B# 16016-10000-07358	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27006	15041-20001-12938	11332 W DONA LOLA DR	91604	2	159B173   410	2380017025	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	34.13218	-118.37782	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27007	14041-10000-31934	14626 W RAYMER ST	91405	6	189B149   548	2210030017	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.21194	-118.45167	Sports bar and lounge tenant improvement - place of assembly.  Occupant load in excess of 100.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27008	18041-10000-02456	20800 W SHERMAN WAY	91306	3	183B109    78	2137020038	[Q]C1.5-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.20086	-118.58629	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27009	19041-20000-48994	15301 W VENTURA BLVD U-2	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	12/12/2020 12:00:00 AM	ADDRESS	34.15411	-118.46654	Distribution, power, and lighting for commercial tenant space TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27010	14041-20001-14025	15724 W LEMARSH ST	91343	12	204B141   583	2661018018	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM			PC Approved	06/01/2014 12:00:00 AM	ADDRESS	34.25539	-118.47483	Expedited plan check per applicant request. (((PV1.  Install 10.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27011	16041-10000-05440	18420 W HART ST	91335	3	183B125  1071	2125011020	M1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Issued	03/16/2016 12:00:00 AM	ADDRESS	34.19737	-118.53366	PC FOR ASSEMBLY OCCUPANCY. RENOVATION OF HEALTH CLUB. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27012	13041-20000-20885	6653 N FALLBROOK AVE	91307	3	180B097   183	2038040013	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	PIN	34.19123265	-118.62539509	T24 FOR EXISTING 24 HOUR FITNESS. SCOPE OF WORK AT THE BASKETBALL COURT. TOTAL SQRFT 4876.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27013	14041-20000-19151	5753 N TROOST AVE	91601	2	174B169   348	2339012045	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.17553	-118.38681	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.08KW AC USING 19 MODULES MICROINVERTER ENPHASE M215. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27014	18041-10000-07714	3016 S SOMERSET DR	90016	10	120B185   529	5050030040	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.02706	-118.33724	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. CONISIT OF 14 MODULES(#SC325) AND A CENTRAL INVERTER (DELTA SOLIVIA 3.8) . SYSTEM SIZE IS 3.8KWac AND 4.55KWdc.SCOPE INCLUDES ONE NEW LOAD CENTER (200A each).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27015	15041-20000-13035	413 W 101ST ST	90003	8	091-5A201 153	6054033017	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	33.94474	-118.28103	Plan check for PV roof mounted 7.14kW micro-inverter connected to existing 200A service with 28 modules and 1 load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27016	16041-10001-01886	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 35 CHANGES-REVISED PANEL SCHEDULES TO SHOW CIRCUITS REMOVED AND ADDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27017	19041-20000-06931	5350 N YOLANDA AVE	91356	3	171B121   132	2161010005	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.16796	-118.54074	Plan check for a PV1 roof-mounted PV system. System size is 9.57 kWdc/8.94 kWac-CEC and consists of (1) 7.6 kWac rated inverter, (29) modules, (1) load center, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27018	16041-20000-37426	1309 W SEPULVEDA BLVD	90501	15	045B197   144	7347018094	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			10/21/2016 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	33.81485	-118.29961	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP, 7 RPS,  AND 817 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27019	12041-20000-11270	13314 W SATICOY ST	91605	2	186B157   199	2303028007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.20813	-118.42286	Plan check for energy, outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27020	19041-10000-03120	6901 W WESTCHESTER PKWY APF	90045	11	093B161     3	4119006913	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	33.95391	-118.41344	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW 5000AMP,480V/277V SERVICE IN LAX FEEDING A TEMPORARY 2000AMP DISTRIBUTION BOARD FOR CONSTRUCTION. NO LOAD ADDED TO DISTRIBUTION BOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27021	13041-10000-31865	12050 W VENTURA BLVD	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.14349	-118.39426	TITLE 24 PART 6 ENERGY WORK FOR A 2600SQ FT COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27022	15041-20001-14089	3760 N GLENRIDGE DR	91423	4	162B157   730	2272027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM			PC Approved	05/16/2015 12:00:00 AM	ADDRESS	34.13898	-118.43214	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Building integrated PV panels are connected to two central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27023	18041-30000-46883	10866 W WILSHIRE BLVD 6 & 15 TH-FLR	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.05907	-118.442	T-24 ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING IN CORRIDORS. NO CHANGE IN USE. TOTAL SQ. FT. 1238.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27024	14041-10000-26250	14504 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.23524	-118.44834	tenant improvement at a waba grillplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27025	14041-20000-33469	4233 N SHADYGLADE AVE	91604	2	165B165   817	2367007019	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.14776	-118.40203	pv1install roof mounred pv system sized 7.6kw interconnected with msp.(31) trina solar tsm-255 modules, (1) solaredge se7600 inverter, (31) power optimizers p300Note: solar PV installation shall comply with FPB rquirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27026	13041-20000-33858	5340 S ALLA ROAD SUITE 110	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	33.9773	-118.42567	PC AND PERMIT FOR T24 ENERGY ONLY. TOTAL AREA 7831 SQ FT. EXISTING OFFICES. NEW LIGHITNG WORK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27027	19041-10001-10891	4424 N BERGAMO DR	91436	5	165B137    59	2284016027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.15206	-118.48686	Expedite per applicant request.(((Plan check for a 18.9KW AC / 18.36KW DC PV1 roof mounted system with (68) modules, (2) inverters, (1) subpanel interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27028	13041-10000-35711	1186-1188 E 43RD PL # 1188	90011	9	114A209   376	5115034014	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.00466	-118.25446	PV1, Install 2.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (10) modules Trina Solar TSM-250PA05.18.One of two systems on the same building from range 1186 to 1188 43rd pl.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27029	17041-20000-20061	865 S FIGUEROA ST 10th Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for energy only. TI to existing offices on 10th floor of high rise building. New lighting - 861sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27030	13041-10000-26344	23956 W HAMLIN ST	91307	12	180B089   672	2033006021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.1883	-118.64838	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A  NON STANDARD PLAN , XFORMERLESS SYSTEM; SYSTEM SIZE IS 3.675KW DC WITH (15) MODULES: TRINA #TSM-245PA05.18(1) POWER-ONE #AURORA PVI-3000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27031	15041-10000-20647	6558 S WEST BLVD	90043	8	102B185    51	4006020045	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			07/21/2015 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	33.97946	-118.335	NEW APT. BLD, 49 UNITS, 4 STORIES. P.C. FOR TI-24 ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27032	19041-10000-10258	8701 S ST ANDREWS PL	90047	8	096A193     3	6036009900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	33.95975	-118.31141	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27033	14041-10000-10251	2535 E 12TH ST UNT # B	90021	14	120A219    28	5168004001	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	PIN	34.02266563	-118.22644618	T24,REMOVE HID LIGHTING FIXTURES AND REPLACE WITH NEW FUORESCENT FIXTURES. TOTAL AREA 22274 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27034	16041-10000-08470	10265 W CHEVIOT DR	90064	5	123B161   138	4316003004	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.03657	-118.40744	PV1 rooftop solar installation with Battery back-up 7.6kW AC system.    (30)Sunpower X21-335-BLK   (1) SE7600A-USSNote: Fees are $0 due to senate Bill 12222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27035	19041-20001-18375	13620 W SUNSET BLVD	90272	11	129B133    86	4408001008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.05241	-118.50314	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET CLOUDED DELTA 2 CHANGES ONLY. CHANGES TO SINGLE LINE AND CONDUIT SCHEDULE. CHANGE IN CONDUCTOR SIZE,  ADDITION OF A NEW CONDUIT AND SPLITTING UP CONDUCTORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27036	15041-10000-33602	404 S FIGUEROA ST	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM			PC Info Complete	09/22/2016 12:00:00 AM	ADDRESS	34.05326	-118.25596	PC FOR POWER. INSTALLATION OF NEW CHILLERS AND BIOLERPLANT AND DDITION SECTION TO EXISTING SWICHGEAR. HIGH RISE BUILDING. E-LEVEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27037	13041-20000-02826	7365 N WESTCLIFF DR	91304	3	186B089   410	2027043012	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	PIN	34.20554652	-118.65340282	New 10.1kw PV system for an existing single-family residence.  System is UNGROUNDED/Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27038	13041-20000-23923	10351 W SANTA MONICA BLVD # 212	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	PIN	34.0585564	-118.42324002	PC FOR T24 ENERGY ONLY. EXISTING RETAIL SAPCE. NEW PARTITIONS AND NEW LIGHTING. TOTAL AREA 1890 SQFT. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27039	19041-20000-51608	12123 W OTSEGO ST	91607	2	171B165   791	2356002013	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.16317	-118.39742	PV1. INSTALL 12.87 KW DC PV SYSTEM WITH (39) MODULES/OPTIMIZERS AND (1) INVERTER (11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27040	17041-10000-27346	8655 N TAMARACK AVE	91352	6	195B169   547	2631018073	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.22749	-118.38593	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY TOTAL 46000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27041	12041-20002-17592	22700 W SHERMAN WAY	91307	12	183B097   111	2024019005	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			PC Approved	01/17/2013 12:00:00 AM	ADDRESS	34.20071	-118.62196	Modification to change wire size from the PV Switchboard to the main.          <<<<<New 20kw photovoltaic system in the carport of a church parking lot.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27042	11041-10000-10284	275 W CENTER WAY PARK-PS-2B	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM			PC Approved	05/19/2011 12:00:00 AM	ADDRESS	33.94386	-118.4047	CHANGE OF LIGHTING TO TEMPORARY WORKSHOP IN PARKING PS-2B AT LAX  (NORTH OF 275 BUILDING).  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27043	17041-10000-19788	520 S LA FAYETTE PARK PL	90057	1	135A201   136	5155019007	CR-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.06376	-118.28241	NEW 600A SUBPANEL TO REFEED BUILDING LOADS AND ALLOW INTERCONNECTION FOR PV SYSTEM (UNDER SEPARATE PERMIT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27044	13041-10000-30244	6735 W FOREST LAWN DR	90068	4	165B185   196	5581028009	C1-1D	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Info Complete	11/15/2013 12:00:00 AM	ADDRESS	34.14466	-118.33917	PLAN CHECK FOR POWER ONLY. 3 STORY BUILDING. CHANGES ARE CLOUDED. REPLACING TWO FEEDERS, 2 PUMPS AND 1 AC UNIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27045	14041-20001-10994	10911 W RIVERSIDE DR	91602	4	165B173    52	2423009048	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Mid-Town North Hollywood		1432.00	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.15243	-118.36809	EXPEDITE PER APPLICANT REQUEST(((PV2Commercial rooftop solar installation. 2-story building.(132) Canadian Solar CSGX-305M pv modules(3) SMA SB11000TL-US transformerless inverters )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27046	18041-20000-23818	22122 W GERMAIN ST	91311	12	207B101   170	2723015069	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.26232	-118.60867	Plan check for PV roof mounted system, system size: 5.0kW with 20 modules and 1 inverter(5.0) center feed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27047	15041-20000-33274	3575 E WHITTIER BLVD	90023	14	121-5A227 227	5188005015	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.02583	-118.1962	Plan check for a fire alarm system in an existing commercial building. Fire alarm system consists of (1) FACP and (60) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27048	17041-20000-46653	1654 N MICHELTORENA ST	90026	13	145-5A205 425	5425001039	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	Yes	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.09102	-118.27343	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. Existing solar pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27049	16041-10002-06388	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	PC FOR CHANGES TO APPROVED SET. ADDED LIGHT IN CLOSET AND UPDATED FLOOR PLAN BACKGROUND.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27050	13041-20002-28889	776 N VINE ST 1st floor	90038	13	141B189   142	5534034011	[Q]C2-2D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Info Complete	11/27/2013 12:00:00 AM	ADDRESS	34.08507	-118.32644	Request for Plan Check for Power only by Engineer.  Energy is approved on the main application.      <<T.I. to an existing restaurant.  Occupancy load is less than 99, load is less than 400 amps.  Plan Check Only for ENERGY.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27051	13041-20000-08078	10237 N DONNA AVE	91324	12	204B121   165	2729002020	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.25674	-118.54845	New 10kw photovoltaic system, rooftop, for an existing single family dwelling.  System uses Enphase Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27052	13041-10000-21509	11714 W SAN VICENTE BLVD	90049	11	129B145    63	4265006024	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.05331	-118.46609	TITLE 24 PLAN CHECK ONLY. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 752 SQFT. EMERGENCY LIGHTING. 1 STORY RETAIL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27053	15041-20000-10749	670 N SAN LORENZO ST	90402	11	124-5A133  19	4408035002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.03694	-118.50938	Plan check for PV1 roof mounted 8.0kW system and 16modules(SUNPOWER SPR-X21-345) with 1 inverter(SMA SB7700TL-US-22)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27054	16041-20000-21962	18433 W ROSCOE BLVD #203	91325	4	192B125   578	2786022035	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.22091	-118.53469	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR MEDICAL OFFICE. SUITE 203	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27055	13041-10000-28885	415 S LA BREA AVE	90036	4	135B181   428	5508006028	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.06635	-118.34436	FA FOR ORCHARD SUPPLY HARDWARE. 1 facp and 91 devices. Wiring in Cable tray: 1)no wall penetrations. 2) all wiring 8ft above ground (minimum).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27056	11041-10000-15483	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	ADDRESS	34.2426	-118.55846	T.I.  Existing DSW.  Single story building.  Plan check is energy only using Tailored Method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27057	19041-10000-47592	1545 W WILSHIRE BLVD SUITE 711	90017	1	132A205   202	5142027036	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.05543	-118.26977	ENERGY PLAN CHECK ONLY, AREA OF SCOPE 1380 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27058	18041-20000-03833	1651 S VIRGINIA ROAD	90019	10	126B185   203	5071008053	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.04437	-118.33274	PV1.  Install 6.65 kW DC roof mounted PV system with 7.6 kW-rated string inverter with battery back-up energy storage system.  (19) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27059	14041-10000-31924	7715 N DENSMORE AVE	91406	6	189B141   266	2206010005	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Expired	12/12/2016 12:00:00 AM	ADDRESS	34.21086	-118.47725	Energy plan check for a general commercial storage T.I. Total area cover 7199 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27060	16041-10000-20110	21600 W NORDHOFF ST	91311	3	195B105     7	2779018038	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.23525	-118.60067	PC for T-24 only, remove HID fixtures and replace with LED fixtures. Total area: 17,473 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27061	19041-10000-25109	2227 N FIGUEROA ST	90065	1	142-5A219 496	5446013058	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.08321	-118.22365	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27062	16041-10001-06296	21013 W SHERMAN WAY #3	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.20125	-118.5914	"Revision to approved plan due to change of floor plan. T-24 remain the same. This is PC only, Permit shall be issued on master E# 16041-10000-06296<<PLANCHECK FOR T24 ENERGY. CHANGE OF USE RETAIL TO RESTAURANT. ""CORN N' CRAB "" 2,087 SQ. FT.>>B# 15016-10001-09179"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27063	17041-20000-43264	7125 W DE LONGPRE AVE	90046	4	147B181   904	5548017035	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.09625	-118.3447	permit fee $0.00 by state senate bill no.1222PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 66 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27064	12041-20000-18616	23335 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.1573	-118.63409	T-24 lighting plan check for retail paint store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27065	10041-10000-23713	17836 W CATHEDRAL PL	91316	5	165B129   207	2184029008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02, 1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2010 12:00:00 AM	01/25/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.14922	-118.52188	NEW 16.38 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27066	15041-10000-26543	633 W 5TH ST LEVEL 1	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY. NEW ENTRY PORTAL TO EXISTING LEVEL 4 LOBBY. TOTAL  AREA  670 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27067	18041-20001-03386	110 W 119TH ST	90061	15	084B201  1033	6087022010	C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2414.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	33.92455	-118.2744	3/29/2018chnages to an aproved set of plans.  changes to downsize system to 3.6kw and reduce modules to 13.this is plan check only.  pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27068	10041-20000-19947	21810 W NORDHOFF ST	91311	12	195B105     4	2779020052	QMR1-1, QP-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.02, 1132.33	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	11/19/2010 12:00:00 AM	ADDRESS	34.23524	-118.60337	Install panels, branch circuits for a Manufacturing building.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27069	19041-10000-48235	6321 N GOODLAND PL	91606	2	177B161    36	2332005001	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.18543	-118.41125	NEW ROOF MOUNTED 7.04KW PV SYSTEM WITH 22 PV PANELS WITH OPTIMIZERS AND A 5KW INVERTER ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27070	16041-30000-01093	6474 N LANGDON AVE	91406	6	180B145   579	2234015006	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.18863	-118.46898	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (65) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27071	09041-10002-14219	13515 S FIGUEROA ST	90248	15	078B201   102	6132005009	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20, 2911.30	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Expired	12/24/2015 12:00:00 AM	PIN	33.90872221	-118.28341949	Changes from previously approved plans.  Changes include one service 277/480 to the building (before two services to building), new 1200A switchboard, panels, and transformer.  All changes indicate by DETLTA-3.  Plan check for power only.*****Delta 2 modifications only.  See the original plan for complete electrical installation.  to the plan26,150  SF, Tenant Improvement to an existing 38, 776 commercial bldg, (N) sanctuary, (N) classrooms,  (N) Activity room.  The site is indicated as  in a Methane Zone in ZIMAS.  Conduit seals required where exiting ground, see conduit to  monument sign j-box.  Sign is future.  Permit to be issued on original submittal.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27072	18041-20000-45567	5750 W WILSHIRE BLVD 4th flr	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.06227	-118.3542	ti to an existing commercial building corridor only.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27073	16041-10000-40724	9175 N ARLETA AVE	91331	6	198B157   843	2625010010	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.2365	-118.42046	PV INSTALL 13.4 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(40) AC MODULES: SUNPOWER SPR-X21-335-C- AC, 4 STRINGS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27074	13041-20001-33869	14225 W DICKENS ST	91423	4	165B153   468	2266003012	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.14885	-118.44292	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE CLOUDED REVIONS NOTED DELTA 2 AND 3. ADDITION OF CIRCUITS FOR PUMPS AND LIGHTS, CHANGE IN LIGHTING LAYOUT. MINOR. PERMIT TO BE ISSUED UNDER THIS APPLICATION FOR ADDITIONAL ITEMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27075	14041-10000-28217	3243 W SAN FERNANDO ROAD	90065	13	153B209   157	5458007015	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.11809	-118.24754	Title 24 plan check only.  Total area = 2,639 sq. ft.T.I. to a bakery space.  One new 200A panelboard will be installed along with lighting and recepticles.Building application submitted before title 24 part 6 deadline.B application number: 14016-10000-10624	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27076	18041-20000-29035	17710 W ROSCOE BLVD	91325	12	192B129   324	2101001028	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.22072	-118.51902	Change of use from retail to dialysis clinic.  OSHPD 3.  (E) 800A 208Y/120V service.Building permit under 18016-20000-20440.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27077	19041-10000-10018	1925 S CENTURY PARK EAST #320	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	ENERGY PLAN CHECK FOR AN INTERIOR OFFICE T.I. IN SUITE 320 LOCATED IN A HIGH RISE BUILDING .  SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 2558-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27078	18041-20000-28158	6254 N BEEMAN AVE	91606	2	177B161   177	2332015002	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.18458	-118.40724	pv1install roof mounted pv system sized 15.2 KW AC interconnected with msp.(55) LG 300W modules(55) p300 optimizers(2) solaredge 7.6KW inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27079	13041-20000-31070	13727 W FOOTHILL BLVD	91342	7	225B157   824	2509015029	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.3093	-118.43233	Plan check for energy and emergency lighting. Low-rise commercial. Building permit is 13016-20000-12876. Rok N' Sushi THIS IS NEW PLAN CHECK FOR LIGITHING AND CHANGE IN CONTRACTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27080	10041-20001-12501	215 W 5TH ST 1-88	90013		129A211    77	5149024005	[Q]C4-4D-CDO		Central City	Downtown Los Angeles			Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	05/22/2012 12:00:00 AM	ADDRESS	34.04788	-118.25017	"Changes from previously approved plans.   Changes include lighting and add outdoor lighting.  All changes indicate by DELT-1 as shown on plans.  Plan check for energy only.*****Remodel to an existing high rise building with 88 units adaptive reuse.  New services, switchboards, emergency generator, panels, and branch circuits.  Install general/emergency lighting.  File variance for separate fire alarm plans.  EPC is for power and energy.  ""COMPLY WITH DEPARTMENT ORDER effective date 08/04/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  Existing permit issued on application number 09041-10000-15831.  A new plan check was generated due to redesign.*****"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27081	16041-10000-41312	1253 N BISHOPS ROAD	90012	1	136-5A215  10	5414019007	[Q]R3-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.06976	-118.23428	Full Plan check (Power&Energy)  to a  school's auditorium and classroom ( Cathedral High School).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27082	13041-20000-17880	11854 W OLYMPIC BLVD	90064	11	123B149   529	4259024004	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Issued	01/23/2014 12:00:00 AM	ADDRESS	34.03259	-118.45147	Change to lighting and loads to an existing commercial retail space.  Full Plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27083	12041-20000-21116	609 N LA BREA AVE	90036	5	141B181   830	5525016006	C4-1VL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM			PC Approved	09/06/2012 12:00:00 AM	ADDRESS	34.0822	-118.34434	Plan check for energy only. Most lights are existing to remain. Emergency lights existing to remain. 3555 sqft restaurant. Bludso's.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27084	17041-20000-41196	4488 N VISTA SUPERBA DR	90065	14	159A215    28	5679019022	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.132	-118.23642	PV1.  Install roof mounted PV system sized 3.8 kW interconnected with essential load back up panel.  (14) modules with 3.8 kW rated string inverter.  13.5 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27085	19041-20000-53115	11863 W JEFFERSON BLVD	90230	11	105B165   323	4220005039	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	09/29/2022 12:00:00 AM		Issued	09/29/2022 12:00:00 AM	ADDRESS	33.98551	-118.40306	PC FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES:  800A (120/240V, 3PH, 4W) SERVICE THAT IS CONNECTED TO A HOUSE PANEL AND A  (800A 120/240V, 1PH, 3W) SWITCHBOARD THAT FEEDS DWELLING UNITS. NEW BRANCH CIRCUITS, MOTORS, LIGHTING AND CONTROLS.  TOTAL AFFECTED AREA: 19,124 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27086	14041-10000-30582	3321 N CHADWICK DR	90032	14	142-5A235 202	5218004030	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.0844	-118.1702	PV1 roof-mounted 5KW system, including (14) Sunpower SPR327NE modules and (1) PowerOne PVI-5000 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27087	14041-10000-06079	1458 S SAN PEDRO ST #321	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  1242 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27088	15041-10000-07596	820 S GLADYS AVE	90021	14	124-5A213 320	5146022007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.03533	-118.24623	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACE HID LIGHTING TO LEDS.  PLN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 16400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27089	14041-20001-07713	13897 N ELDRIDGE AVE	91342	7	228B153   687	2503003019	RE11-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	34.32445	-118.43353	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27090	19041-10000-04023	4001 W 6TH ST	90020	4	135B193   869	5503017002	C2-1	Central	Wilshire	Greater Wilshire		2117.04	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.06364	-118.31057	FULL PLAN CHECK FOR CHANGE OF USE FROM (E) NIGHT CLUB/ KARAOKE TO RESTAURANT . NEW 600A SERVICE, MOTOR LOADS, LIGHTS AND POWERS. TOTAL AREA: 11,305 SQ.FTB# 18016-10000-38073	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27091	17041-10000-15537	1111 S BROADWAY	90015	14	126A209   139	5139019035	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	06/03/2021 12:00:00 AM	ADDRESS	34.03943	-118.25948	PC FOR POWER AND ENERGY. CORE AND SHELL OF AN EXISTING BUILDING WITH PROVISION FOR FUTURE TENNATS. SCOPE OF THE PROJECT INCLUDES  0-5 LEVELS. SERVICE SIZE 5000 AMP, TOTAL AREA 19926 SQ FT.B # 16016-10000-19257	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27092	12041-20000-27042	15906 W SIMONDS ST	91344	12	210B141    29	2666013007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.27625	-118.47844	PV-1. Plan check for PV. Microinverters, 8kW DC. FEE FOR MONITORING SYSTEM ADDED TO PERMIT FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27093	19041-20001-42109	10520 N WHITE OAK AVE	91344	12	207B129   863	2733011027	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	34.26173	-118.51949	12/9/19 $0 fee due to AB1414CHANGES TO APPROVED SET CHANGES TO RELOCATION OF INVERTER. <<<Plan check for PV roof mounted system, PV system size: 3.285KW DC, 3.0KW AC with 9 PV Modules and 1 inverter(3.0KW) connected to center fed panel.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27094	15041-10000-07104	950 W JEFFERSON BLVD	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.02484	-118.2869	NEW DISTRIBUTION BOARD 200 AMPS BAB-H WITH NO CONNECTED LOADS, CONNECTED TO EXISTING DISTRIBUTION BOARD DBA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27095	10041-20000-02856	15331 W RAYEN ST	91343	7	195B145   243	2654005029	M1-1	North Valley	Mission Hills - Panorama City - North Hills			1175.10	Electrical	Electrical	Public Safety Only			02/18/2010 12:00:00 AM	02/18/2010 12:00:00 AM		Permit Closed	05/26/2010 12:00:00 AM	ADDRESS	34.232	-118.46643	INSTALLING FIREALARM IN OFFICE SPACES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27096	11041-10000-10073	11674 W SANTA MONICA BLVD	90025	11	126B149   285	4262008018	(T)(Q)C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM			PC Info Complete	11/20/2013 12:00:00 AM	ADDRESS	34.04379	-118.45551	new vons store , power lighting, energy indoor and out door. all electrical work new.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27097	15041-20001-08466	9423 N RESEDA BLVD UNIT B	91324	12	198B125   467	2763035025	C2-1VL, P-1VL, RA-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.24178	-118.53643	PC FOR T24 ENERGY ONLY. THIS IS BARBER SHOP. LOW LOADS. NO DIM REQUIRED. LESS THAN .5W/SFNO POWER PC NEEDEDTHIS APP IS PC ONLY. PERMIT UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27098	19041-10000-19716	5975 N SHOUP AVE	91367	3	177B101   160	2040041008	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM			Ready to Issue	10/25/2019 12:00:00 AM	ADDRESS	34.17892	-118.61491	FULL PLAN CHECK FOR SCHOOL TENANT IMPROVEMENT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1830 SQ.FTBUILDING # 95-5B#19016-10000-15469	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27099	12041-10000-12256	111 E UNIVERSAL HOLLYWOOD DR 10TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING EXISTING FLOOR HAVING OFFICES; NEW LOAD IS LESS THAN 400 AMPERES.PLAN CHK IS FOR TITLE 24 AND 1 EACH EMERGENCY LIGHT; ON 10TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27100	18041-30001-18042	1026 S BROADWAY	90015	14	126A209    92	5139014017	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.04029	-118.25788	05/02/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to reflect field installation.*****Original Work Description*****FULL PLAN CHECK IN A NEW CVS PHARMACY STORE. (POWER & ENERGY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27101	13041-10000-03362	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM			PC Approved	02/15/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	ALTERATION OF GYM SPACE. T24 ONLY. TOTAL AREA OF 6895. NOT PART OF HIGHRISE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27102	13041-20000-01175	6549 N PEACH AVE PV-1	91406	6	180B145   424	2234018010	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2013 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.19009	-118.46781	PV-1. Microinverter standard plan. 2.58kW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27103	17041-20000-34509	7749 N QUIMBY AVE	91304	12	189B097   974	2014032021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.21156	-118.63076	Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.7.6kW ungrounded pv system. (30) 325W pv modules. (2) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27104	15041-20000-29709	8748 S READING AVE	90045	11	096B169   714	4125016009	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			09/09/2015 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	33.95865	-118.38146	Fully sprinklered 45' x 94' irreg. shaped three story 10 unit, including 1 low income with 2 bonus units(10% of base density of 8 units) apartment over garagePlan check for power only. Adding new 800A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27105	13041-10000-05077	3550 W WILSHIRE BLVD SUITE 1418	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	34.06157	-118.30226	PLAN CHECK FOR T24 ENERGY AND EMERGENCY LIGHTS. TENANT IMPROVEMENT OF THREE OFFICES AND HALLWAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27106	16041-10000-38880	3991 S WESTERN AVE # 7	90062	8	114B193   185	5035008024	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.0116	-118.30912	Plan check for power and energy for Dental office Change of use from retail to Dental office. Total area: 1,226 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27107	12041-10000-01164	9413 S SPRING ST	90003	8	093A203    60	6053006922	RD1.5-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Apartment			01/18/2012 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	33.95054	-118.2769	NEW 3-STORY, 49 UNITS APARTMENT BUILDING, TYPE VA,  98% AFFORDABLE HOUSING DEVELOPMENT.   W/48 SENIOR AFFORDABLE  UNITS, AND ONE MANGERS UNIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27108	14041-10000-30208	244 S AVENUE 18	90031	1	138A219   165	5447025021	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Apartment			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.07044	-118.22153	Installation of new fire alarm system in a new 6 unit 2 story apartment building.  35 Fire alarm devices + 1 control panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27109	15041-10001-40773	1865 S LA BREA AVE	90019	10	126B181   962	5067014030	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM			PC Approved	08/10/2016 12:00:00 AM	ADDRESS	34.0408	-118.34755	Extended planc check for power. Change of of voltage rating from 120/208V 3phase 4Wire to 120/240V 3phase 4Wire. changes noted delta 1 revision(((PLAN CHECK FOR POWER AND ENERGY FOR PROPOSED NEW RESTAURANT WITH 600A SERVICE 5000SQRFT.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27110	12041-10000-02955	131 S BARRINGTON PL	90049	11	135B145   480	4402008011	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM			PC Approved	02/08/2012 12:00:00 AM	ADDRESS	34.0664	-118.46933	Tenant improvement in an art gallery-new lights and circuitsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27111	13041-10000-20912	802 S LOS ANGELES ST	90014	14	127-5A211 318	5145013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.04167	-118.25238	TITLE 24 WORK PERTAINING TO RETAIL STORE. SCOPE OF WORK INCLUDES REMOVING EXISTING LIGHTING FIXTURES & REPLACING WITH NEW LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27112	17041-20000-14082	8900 N CORBIN AVE	91324	12	195B117    43	2783025026	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.23252	-118.56211	PLANCHECK FOR POWER.  INSTALLATION OF NEW CAR WASH EQUIPMENT IN AN EXISTING CARWASH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27113	18041-20000-05833	3649 N CROWNRIDGE DR	91403	5	162B141   421	2280009020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.13703	-118.47627	Installation of 13.5 kWh energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27114	17041-10000-42707	6600 N TOPANGA CANYON BLVD #207A	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Closed	04/27/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24, PC FOR ENERGY ONLY. TI FOR EXISTING RETAIL STORE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1310 SQ. FT. B#17016-10000-35133	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27115	12041-20000-27086	6250 W HOLLYWOOD BLVD GROUND	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Approved	11/14/2012 12:00:00 AM	ADDRESS	34.10133	-118.32547	Plan check for energy and emergency lighting. Combination of Phases 1 and 2. 4114 sqft. Low-rise commercial building. Ground floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27116	18041-10000-23314	7635 N GLADE AVE	91304	3	186B101    34	2012021072	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.20932	-118.60833	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27117	17041-20000-43282	229 N BURLINGTON AVE #5	90026	13	136-5A207 286	5159006009	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM			Reviewed by Supervisor	01/12/2018 12:00:00 AM	ADDRESS	34.06717	-118.26626	plan check for power only.NEW 4 STORY SINGLE FAMILY DWELLING W/ ATTACHED GARAGE. (PART OF NEW SMALL LOT SUBDIVISION). 5 of 6 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27118	12041-10000-27556	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	12/05/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	PLAN CHECK FOR TITLE 24 IN A TUNNEL IN THE WESTFIELD MALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27119	10041-10001-23341	5771 W 96TH ST	90045	11	093B169   134	4125021010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	33.94955	-118.38342	New manufacture. New panel and circuits. EPC is for power and energy. (BLG# 5771) ((((((((((((((((((((((((((((((((((((((addition of 40  amps panel H4 withe two 20 HP and one 150 HP kettle))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27120	10041-10000-17760	6990 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles				9800.28	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	PIN	33.93847109	-118.41935625	LAWA - airfield electrical lighting- USING EXISTING CIRCUIT ( A7 )  TO POWER RELOCATED RUNWAY LUMINAIRES ; THESE LUMINAIRES WERE RELOCATED AS THE TAXIWAY WAS DIVERTED TO MAKE ROOM FOR THE EXPANSION OF THE TBIT BUILDING. DUCTBANKS WERE EXTENDING TO ACCOMODATE THE CIRCUIT CONDUCTORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27121	14041-20000-25397	23355 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Closed	05/01/2015 12:00:00 AM	ADDRESS	34.1579	-118.63422	Replacement of 1600A service equipment and tenant panels in disrepair - ER2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27122	19041-20000-00779	4864 W MELROSE AVE	90004	13	141B193   595	5521004030	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Apartment			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	06/23/2021 12:00:00 AM	ADDRESS	34.08334	-118.30645	new fire alarm system 168 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27123	10041-10000-02561	11601 W WILSHIRE BLVD #710	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM	02/16/2010 12:00:00 AM		Permit Finaled	04/08/2010 12:00:00 AM	PIN	34.0509267	-118.45996763	TI - highrise - office suites in Ste. 710.  Permit is for new emergency ckts.  P/C is for lighting and emergency.  Original permit is 10041-40000-01130.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27124	11041-10001-12385	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM			PC Info Complete	04/09/2012 12:00:00 AM	ADDRESS	34.05855	-118.23671	T.I.  Remodel in an existing building in the basement for a data center.  The building is 4 stories high.  Plan check is for power and energy. (((((((((((((((((((((((((( 2-17-2012 some of the equipment did not get installed inspector  told the contractor , due to discrepency of the plans , to bring the new  sets  with all the the changes shown to the epc to review and re- stamp.)))))))))))))))))))))))))))))))))))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27125	18041-20000-01024	17107 W VENTURA BLVD	91316	5	168B133    17	2258012028	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.16046	-118.50575	Plan check for a PV2 roof-mounted PV system. System size is 72 kWac and consists of (3) inverters, (1) load center, and (244) modules.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27126	13041-20000-36326	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.07149	-118.19797	"((( "" $0 permit fee is due to the 2012 Senate Bill No. 1222"" )))PV2 COMMERCIAL ROOFTOP PHOTOVOLTAIC SYSTEM, TOTAL SYSTEM SIZE 3.89 MEGAWATTS AC. TOTAL OF 5.07 MEGAWATTS DC. USING TOTAL OF 141 TRANSFORMERLESS INVERTERS. ROOFTOP OF FOREVER 21 COMMERCIAL BUILDING. TOTAL OF 4 SERVICE INTERCONNECTIONS. USING TOTAL OF 15512 SUN POWER 327W MODULES."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27127	11041-20000-16168	585 E NORTH VENICE BLVD	90291	11	108B145  1530	4241037014	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	PIN	33.98977332	-118.46215915	Plan check power and energy. New 600A service electrical system to existing retail building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27128	16041-10000-00898	2124 E 103RD ST	90002	15	091-5A217  23	6066012068	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Expired	02/08/2018 12:00:00 AM	ADDRESS	33.94301	-118.23399	PV1, rooftop solar installation 3.6kW AC system.(16) TRIEX U290 Black(1) PVI-3.6-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27129	13041-20000-23790	10404 S AVALON BLVD	90002	8	090A207   112	6051027011	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	PIN	33.94170257	-118.26482837	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING 20 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27130	12041-20000-03137	17941 W CHATSWORTH ST PAD J	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.26503	-118.52485	"NEW ONE STORY RETAIL BLDG  ""J"" - SHELL ONLY .  Power and T24 energy for exterior and restrooms areas only."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27131	10041-20000-11987	555 W 5TH ST 4th Floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check T-24 Enegy for general lighting on the 5th floor. Add fixtures and relocate fixtures. Emergency lighting existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27132	17041-20000-19154	700 S FLOWER ST 11th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is the 11th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 574 sq. ft.Note: Building application has been generated under 17016-30000-07662	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27133	16041-30000-22710	14055 W ARCHWOOD ST	91405	11	180B153   126	2238006031	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	PIN	34.19323012	-118.43959396	NEW FIRE ALARM SYSTEM 97 DEVICES 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27134	17041-10000-05275	5850 S FIGUEROA ST	90003	9	108B201  1499	6004036010	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	33.98825	-118.28246	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 42,700. .	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27135	17041-20002-31694	2967 N HOLLYRIDGE DR	90068	4	156A191    37	5583017001	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.12259	-118.3199	01/19/2018 Changes to an approved set of plans. Changes include the addition of a load center and an AC disconnect. All changes have been reflected onto the SLD and the site plan. *****Previous Work Description*****PV1.  Install 8.45 kW roof mounted grid tied PV system.  (26) modules with 7.6kW rated string inverter.  13.5 kWh backup energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27136	13041-10000-04556	785 N VIGNES ST Level 3	90012	14	132A217   391	5409025***	ADP, [Q]M3-1	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			02/21/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.05606	-118.23248	T24 for office building on the Third floor. 9120 sqrft. Highrise building. Permit has already been pulled therefore this is a plan check ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27137	18041-10000-02465	8966 N COMANCHE AVE	91311	12	195B113    11	2781035047	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.23418	-118.57215	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 48425 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27138	13041-10000-33036	10658 N VANORA DR	91040	7	207B185   445	2547025003	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Expired	02/08/2016 12:00:00 AM	ADDRESS	34.26192	-118.32905	PV1, Install 2.75 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE3000A-US. (11) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27139	18041-10000-37397	777 S SANTA FE AVE	90021	14	124-5A217 364	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	PLAN CHECK FOR ENERGY ONLY FOR - ADDITION -- NEW TRELLIS LOCATED BETWEEN EXISTING PARKING STRUCTURE AND OFFICE BUILDING. - TOTAL AFFECTED AREA (SCOPE OF WORK) = 990 SF. TOTAL HARDSCAPE AREA WITHIN BUILDING = 5616 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27140	16041-10000-04719	1108 S WETHERLY DR	90035	5	132B169   518	4332008036	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.05674	-118.38869	PV1 rooftop solar installation 11.5kW AC system(36) Sunpower X21-345(1) SB3800TL-US(1) SB7700TL-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27141	19041-20000-45401	4520 W DORAN ST	90039	13	168B201   160	5593005035	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	10/21/2021 12:00:00 AM		Issued	10/21/2021 12:00:00 AM	ADDRESS	34.15301	-118.27727	PLAN CHECK FOR POWER UPGRADE SERVICE TO 800 AMP. SCOPE OF WORK INCLUDES PANELS AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27142	12041-10000-29023	10125 W VALLEY SPRING LANE	91602	4	165B181   478	2424035011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.14651	-118.35118	New roof mounted PV1 for a single family. (use enphase 215, MODULES SHALL BE ISTED BY THE CITY OF LA RECOGNIZE TESTING AGENCY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27143	18041-10000-36208	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.05855	-118.23671	Full plan check for data center T.I, Scope includes (1) medium voltage gennerator,  (2) 1200 Board, (6) 1125kva transformers, (2) 4000-Amp board and all other equipment .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27144	18041-10000-43559	1150 S HOPE ST	90015	14	126A207    58	5139021001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.04097	-118.26403	PC FOR ENERGY ONLY FOR A CHANGE OF USE FROM WAREHOUSE TO OFFICE/STORAGE. SCOPE INCLUDES NEW CIRCUITS CONTROLS AND RECEPTICALS. TOTAL AFFECTED AREA IS 2450 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27145	18041-20000-21223	2222 N MARAVILLA DR	90068	4	150B181   103	5549013025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.11034	-118.34337	PV1.  Install 6.825 kW roof mounted grid tied PV system.  (21) modules with 6.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27146	18041-10001-27989	1320 E NEWTON ST	90021	14	121-5A213 102	5130011033	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			Corrections Issued	04/24/2019 12:00:00 AM	ADDRESS	34.02746	-118.24664	"VOID, PLAN CHECK AND PERMIT APPROVED UNDER 19041-10000-15060DELTA ""5"" CHANGES TO APPROVED PLANS.  Existing Service to remain, therefor ""Controlled Receptacles"" are not provided.<<<CHANGE OF USE FROM PARKING TO OFFICE & WAREHOUSE. INSTALL NEW SERVICE, 250KW GENERATOR, PANELS, & LOADS. PLAN CHECK FOR POWER & ENERGY. 16,500SQR FT.BLDG PERMIT: 18016-10000-23726>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27147	14041-10000-32844	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.07583	-118.37407	T24 and power plan check.  Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects. Area = 1849 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27148	15041-10000-06133	7117 S VERMONT AVE	90044	8	102B197  1070	6014036018	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	33.97499	-118.29199	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2729.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27149	10041-10000-15129	20801 W RINALDI ST	91311	12	210B109   548	2706007024		North Valley			YES	1131.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	34.27025	-118.58647	New gymnasium building.  New service, switchboard, panels, and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27150	17041-10002-28796	10334 N ORO VISTA AVE	91040	7	204B189   392	2560013007	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.25711	-118.31562	01/24/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta E. Module manufacturer and model has changed. *****Previous Work Description*****PC FOR ROOF MOUNTED PV ON SLD SYSTEM SIZE 3.0KWAC USING CENTRAL INVERTER WITH STORAGE BATTERY. INCLUDING 11 MODULES AND LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27151	15041-10001-35735	5301 N TOPANGA CANYON BLVD	91364	3	171B101   482	2169016008	C2-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.16611	-118.60613	CHANGE LIGHTING TYPE. NEW LAYOUT AND UPDATED TITLE 24 FORMS. PC FOR CHANGES NOTED DELTA 1 REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27152	16041-10000-18252	10326 N STAFFORD LANE	91311	12	204B113   126	2707015012	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.25823	-118.57752	PV1 SFD TOTAL SYSTEM SIZE 6.02KW AC USING 28 MODULES MICROINVERTER SYSTEM WITH ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27153	18041-20000-26952	5990 N SEPULVEDA BLVD 2nd Floor	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.17911	-118.46588	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,163 sq. ft.Note: Building application has been generated under 18016-10000-22291	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27154	10041-10000-11879	3333 S FIGUEROA ST #ugy-5	90007	8	120A203   502	5123009012	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	ADDRESS	34.02233	-118.28003	T.I. FOR RESTAURANT 1,175 SQFT.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27155	11041-10000-01723	609 W 7TH ST 2nd floor	90017	9	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM	03/16/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.04764	-118.25687	Installing 2 New 150 KVA UPS for Data center. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27156	15041-20000-13667	3033 W WILSHIRE BLVD	90010	10	135B197  1240	5077008018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Closed	09/16/2016 12:00:00 AM	ADDRESS	34.06198	-118.28733	Plan check for Temp Power 1600A service with 8 Transformers(75KVA) and 20 Panels(200A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27157	19041-10000-36258	2640 E WASHINGTON BLVD	90021	14	118-5A219 112	5168017012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.01718	-118.22433	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27158	19041-20000-39902	10871 W OLINDA ST	91352	6	195B173   590	2408010019	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.22709	-118.36726	PV1. INSTALL 4.64 KW DC / 3.8 KW AC PV SYSTEM WITH (16) MODULES/OPTIMIZERS AND (1) INVERTER(SE3800H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27159	07041-10001-01700	4374 N TROOST AVE 1-6	91604	2	165B169   357	2365021006	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Apartment			08/04/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.14953	-118.38649	6 units apartment with 3 stories.  Underground parking.  permit was obtained on original on 12/10/2008 ; refund was granted 10/23/09	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27160	12041-10000-11418	5546 S WESTLAWN AVE	90066	11	105B161  1039	4211005018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	33.97991	-118.41409	NEW VERIZON MAINTENANCE YARD FACILITY; 5,300 S.F. BUILDING & PARKING LOT, TRASH ENCLOSURE (BLDG. LOCATED IN METHANE ZONE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27161	18041-20000-41940	8554 N DELCO AVE	91306	3	192B109    73	2781009020	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Issued	11/01/2018 12:00:00 AM	ADDRESS	34.22616	-118.57822	Plan check for PV roof mounted system, system size: 8.58kW DC, 7.985kW AC with 26 PV Modules and 28 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27162	19041-20000-43539	5366-5368 W PICO BLVD	90019	10	129B177  1044	5069032002	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.04827	-118.35545	Plan check for Title 24 Energy only, new lighting. Total area: 1979 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27163	17041-30000-19307	21851 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.16859	-118.60346	Plan check for Title 24 only. Project site is an existing tenant space within a commercial building. Project scope is a change of use from beauty salon to coffee shop/tenant improvement. Total lighting area = 1,806 sq. ft.Note: Building application has been generated under 17016-40000-15378	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27164	15041-20000-18145	8508 N SHARP AVE	91352	6	192B165   230	2634040031	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.22486	-118.40184	Plan check for PV roof mounted system. System size: 6.0kW with 28 modules and 1 inverter (6.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27165	15041-10001-30939	11455 W BURBANK BLVD BLDG A&B	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	08/17/16Changes to an approved set for Church of Scientology-Areas A &B. All changes are clouded under 9. Changes include revising the single line diagram, panels schedules, and power/lighting floor plans. (((((TI to an exisiting religious assembly site (2-story building), Church of Scientology-Areas A &B. All equipment is new except the service. Full Plan Check for power and energy. Total Sq ft = 65,971.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27166	18041-10001-30073	18500 W BRYMER ST	91326	12	213B125   218	2872018027	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.2818	-118.53525	Changes to approved plans for reducing the number of PV modules from 33 to 26. 7.93 KW (DC) SystemPlan Check Only. Electrical Permit was issued under 18041-10000-30073<<<PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 7.6KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 33 MODULES AND (P320 OPTIMIZERS)>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27167	14041-20001-20691	20008 W VINTAGE ST	91311	12	204B113   715	2726003035	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.25165	-118.56961	(($0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012))CHANGE IN SYSTEM SPECIFICATIONS. NOW USING (2) 3.8KW INVERTERS MAKING SYSTEM SIZE 7.6KW AC. NUMBER OF MODULES REMAIN THE SAME. NEW STRING CONFIGURATION. USING POWER OPTIMIZERS. PERMIT ISSUED FOR POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27168	17041-10000-34806	10635 W SANTA MONICA BLVD #350	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.05353	-118.43031	Title 24 plan check  for office TI. Total area 6603sqft. Installing new panels, receptacles, new and retrofit lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27169	17041-20001-00546	7333 N FULTON AVE	91605	2	186B157   443	2328029032	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.20396	-118.42265	07/25/2018 Changes to an approved set of plans. Lighting fixtures have been revised and all changes have been reflected onto the Title 24 compliance forms. Method of load separation has changed. *****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from manufacturing to industrial multi-tenant catering kitchens. Total lighting area = 9,669 sq. ft.Note: Building application has been created under 16016-20000-18257	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27170	10041-10000-22403	2000 S COTNER AVE 1-2	90025	5	126B153   513	4323024004	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	ADDRESS	34.0421	-118.44158	installation of a 800service /swbd in an existing commercial space- tenant not yet in the building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27171	13041-10000-30016	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	33.94502	-118.40714	PERMIT FOR 13041-10002-20195.TENANT IMPROVEMNTS TO TERMINAL 3 TO ACCOMMODATE THE RELOCATION OF US AIRWAYS INTO TERMINAL 3 SPACES. TITLE 24 PLAN CHECK ONLY.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. LOCATION G.	N	N	Express Permit	06/10/2024 12:00:00 AM
27172	16041-10000-20793	206 W 77TH ST	90003	9	099B201   236	6031017015	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	33.96966	-118.27634	INSTALL NEW 2.12KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27173	16041-10000-34579	8425 N SEPULVEDA BLVD	91343	6	192B145   296	2654027007	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Issued	09/30/2016 12:00:00 AM	ADDRESS	34.22371	-118.46799	PC FOR T24 ENERGY ONLY FOR AUTO REPAIR AND SALES. REPAIR BAY NON HAZARDOUS. SUBJECT TO FIELD INSPECTION TOAL SQFT = 19000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27174	14041-10000-27358	6650 N CAMELLIA AVE	91606	2	180B169   375	2320022003	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Expired	10/24/2016 12:00:00 AM	ADDRESS	34.19181	-118.38219	Solar PV roofmounted residential standard plan. # of inverters installed: 1. System size: 6kW. # of modules: 30.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27175	17041-20000-17246	6060 W CARLTON WAY	90028	13	148-5A189 246	5545007001	C4-1	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Issued	10/04/2017 12:00:00 AM	ADDRESS	34.10036	-118.32207	TI to (E) commercial building for a restaurant.  New 400A 120/240V 3ph-4w service.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27176	18041-10000-44005	110 E 9TH ST BLD. C	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	"FULL PLAN CHECK FOR POWER AND ENERGY (CORE & SHELL) IN AN EXISTING 14 STORY HI RISE BUILDING ""C"".   3 NEW 277/480 SERVICES (4000A + 2500A + 1600A), AREA APPROX. 583,018 SQR FT.  BUILDING PERMIT:"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27177	13041-10001-25859	5510 S LINCOLN BLVD 4TH FLR	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	33.97299	-118.43051	][][]changes made to an approved set of plans; changes is for the renovation of 4th elevator lobby lighting and hallway lighting. scope of work to account for this change is < 400a. no other additional changes.E-permit to be pulled @ electrical plan check counter ][][][  TENANT IMPROVEMENT ON 4TH FLOOR. CONNECTED LOAD IS GREATER THAN 400A. PLAN CHECK IS FOR POWER AND ENERGY.  (1) 50KVA UPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27178	15041-10000-01075	12526 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	33.97833	-118.41207	Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps. Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27179	12041-20000-29335	19313 W STARLIGHT DR	91356	3	168B117    31	2175003014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM			Corrections Issued	12/10/2012 12:00:00 AM	ADDRESS	34.16033	-118.55442	Photovoltaic system on roof of single faimily dwelling, two strings and 3000 watt inverter.  Applicants requests plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27180	14041-10000-14145	9272 W ROBIN DR	90069	4	147B169   216	5561006026	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM			PC Info Complete	09/10/2014 12:00:00 AM	ADDRESS	34.10119	-118.39142	PLAN CHECK FOR POWER FOR NEW SINGLE FAMILY RESIDENCE WITH 600AMP SERVICE SIZE.1/25/2018 THIS IS AN OLD DESIGN WHICH WAS ABANDAND.NEW DESIGN WITH PERMIT UNDER 18041-10000-03018STATUS CHANGED TO PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27181	19041-20000-44908	371 S ANDERSON ST	90033	14	127-5A219 340	5172015017	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	06/11/2020 12:00:00 AM	ADDRESS	34.04262	-118.22584	Power and lighting for (E) building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27182	10041-20000-15470	1722 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   327	5021032023	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	12/02/2010 12:00:00 AM		Permit Closed	10/01/2012 12:00:00 AM	ADDRESS	34.01068	-118.30985	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM OFFICE TO MIDDLE SCHOOL. MODIFICATION TO HAVE (2) SERVICES OF SAME CHARACTERISTIC SUPPLYING BUILDING HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27183	15041-20000-27183	515 S FLOWER ST 35th floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI to existing high rise commercial building (hallway). Plan check for energy only. Adding new lighting including emergency. Total sqft. 683.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27184	14041-10000-10624	551 W 189TH ST STE E	90248	15	063B201   200	7339008030	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	33.86427	-118.28329	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27185	14041-10000-12531	1335 S SIERRA BONITA AVE	90019	10	129B177   510	5085028026	R1-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			05/12/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Expired	09/21/2016 12:00:00 AM	ADDRESS	34.05094	-118.35876	PV1 7KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(28)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]      module Grounding method: lay-in lugs	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27186	18041-30000-17395	12136 W SANTA MONICA BLVD	90025	11	126B145   771	4263037004	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			PC Approved	05/10/2018 12:00:00 AM	ADDRESS	34.04006	-118.464	Energy plan check for a market place T.I. permit fee is paid under 18041-90000-13829. This applicatioon is for plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27187	11041-10000-15027	920 S WALL ST	90015	14	126A211   383	5145017019	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	12/21/2011 12:00:00 AM	ADDRESS	34.03808	-118.25234	First time tenant.  New retail store to occupy the existing 2-story building.   Everything is new.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27188	17041-10000-03531	5017 N LAUREL CANYON BLVD	91607	2	171B165  1025	2356004017	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.16172	-118.39681	PC FOR FIRE ALARM FOR A 2-STORY APARTMENT BUILDING.  79 DEVICES AND 4 FIRE ALARM PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27189	18041-10000-06617	936 N PINE GROVE AVE	90042	14	159A231   383	5481004034	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.13206	-118.18629	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.610KWdc / 4.93KWac.(17)AC MODULES-LG NEON 2ACe	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27190	18041-20000-25169	971 N LINDA FLORA DR	90049	5	141B145    19	4368024004	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM			PC Approved	10/02/2018 12:00:00 AM	ADDRESS	34.08632	-118.46447	Plan check for power only 800A  Service and 14kW Standby Generator  in Single Family Dwelling 2 story building . New 7,626 sq ftl residence. Plan check only, Permit for electrical is under Building application 17010-10000-01925	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27191	17041-20002-25412	1396 W EAGLE VISTA DR	90041	14	162A229    35	5691012036	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	PIN	34.14008288	-118.19424559	12.13.2017 - Plan check for modifications to approved set. Update SLD to show interconnection at (E) subpanel instead of line-side tap.======PV2. APT. ROOMFOUNTED INSTALLATION . SYSTEM SIZE: 7.4 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27192	19041-10001-48400	4960 N RIGOLETTO ST	91364	3	171B097  1035	2075018014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM			PC Approved	01/07/2020 12:00:00 AM	ADDRESS	34.16116	-118.62512	EXPEDITE FEESPV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 11.4 KWac/11.78 KWdc. SCOPE OF WORK IS 38 MODULES (S-ENERGY SN310) WITH OPTIMZERS (SE P320) AND A CENTRAL INVERTER (SE11400H-US).  NOTE MAIN BREAKER HAS BEEN DERATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27193	10041-20000-12733	6112-6114 N LANKERSHIM BLVD	91606	2	177B169   473	2338005008	C2-1, P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM			PC Info Complete	07/02/2010 12:00:00 AM	ADDRESS	34.18165	-118.38453	Plan check T-24 Energy (general/emergency) lighting for retail TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27194	10041-30000-12695	17424 W VENTURA BLVD	91316	5	171B129   462	2290004001	C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Expired	10/24/2012 12:00:00 AM	ADDRESS	34.16109	-118.51254	changing light fixture for office area. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27195	18041-20000-47152	11932 N SONOMA WAY	91326	12	216B117    48	2872004006	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.28957	-118.55285	PV1.  Install 9.425 kW DC roof mounted grid tied PV system.  (29) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27196	16041-20000-31880	14853 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29555	-118.455	Plan check for roof-mounted solar array on SFD. Interconnect with 200A MSP.3kW ungrounded system. (11) 305W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27197	11041-10001-20759	400 W WORLD WAY #4A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	04/20/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Modification to a previously approved set of plans.  Change to lighting, relocation of circuits, moving fan coils from roof to ceiling space.  New Electric water heater.         <<<<1st time tennant for Terminal 4 / Space 4A at LAX.  Plan check for Power and Energy.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27198	19041-20000-17827	615 W FLORENCE AVE	90044	8	102B201   857	6013024013	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	08/24/2020 12:00:00 AM	ADDRESS	33.97482	-118.28428	T24 PLAN CHECK FOR EXISTING COMMERCIAL BUILDING LOW RISE. OUTDOOR LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 21,600SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27199	18041-10000-30244	22450 W SHERMAN WAY	91307	12	183B101    99	2024016109	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.20073	-118.61672	REPLACE EXISTING FLUORESENT TROFFERS WITH NEW LED RETROFIT KITS, AND REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27200	17041-10002-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	SUPP. PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER BULLETIN 8. SCOPE INCLUDES REVISIONS TO LIGHTING INCLUDING T-24 FORMS REVISIONS,  ADDITION AND REMOVAL OF CIRCUITRY INCLUDING REVISIONS TO PANEL SCHEDULES TO REFLECT CORRECT LOADING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27201	17041-10000-16259	21015-21025 W OXNARD ST	91367	3	177B105    72	2149005033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.17944	-118.59106	Change of use and T.I. to a golf course training facility. Scope of work inlcudes new lighting and receptacles. Total Sq. ft. 1873	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27202	11041-20000-24457	10921 W WEYBURN AVE	90024	5	135B149   587	4363018030	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.06273	-118.44617	T.I.  New retail store to occupy existing retail space.  Changing light fixtures and adding new out lets.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27203	16041-20000-37618	18250 W ROSCOE BLVD	91325	12	192B125   681	2102022034	C1-1VL, R1P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.22064	-118.53113	TI to (E) 3-story commercial medical building common area 3rd floor hallway and 2nd floor restroom.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27204	19041-20000-53918	22857 W LEONORA DR	91367	3	171B097   316	2042015010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.16663	-118.62527	PV1.  Install 4.875 kW DC / 4.510 kW AC roof mounted PV system.  (15) modules with 5 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27205	16041-20000-23950	15139 W FRED WAY	91405	6	186B145  1118	2209034007	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.20921	-118.46331	PV1.  Install 3.6 kW roof mounted PV ysstem.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27206	12041-20000-19966	11030 N SUNNY BRAE AVE	91311	12	210B109   111	2707033054	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	ADDRESS	34.27103	-118.58028	New roof mounted P.V. system with 7.8KWdc.  + Additional circuit for monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27207	12041-10002-03519	9540 N VAN NUYS BLVD	91402	6	201B149   735	2644025901	P-1VL, RD2-1, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.24411	-118.45004	CHANGES TO APPROVED SET. REMOVE OC SENSOR FROM COMMUNICATION ROOM and put it on normal switchSUPPLEMENTAL PLAN CHECK TO 12041-10000-03519. CHANGE OF LUMINAIRE TYPES. DELTA CHANGES ARE CLOUDED.  Plan check for T24 Energy/Emergency lighting for City of LA Multipurpose Center. Indoor and outdoor lighting. Building less than 100 occupants.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27208	12041-20000-27294	254 S HOPE ST	90012	14	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/14/2012 12:00:00 AM	ADDRESS	34.05377	-118.25196	Change to lighting in an existing bakery/restaurant.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27209	15041-10000-34609	4061 S BROADWAY	90037	9	115-5A203 254	5111004009	M1-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.0098	-118.27859	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27210	16041-10000-21422	2827 S VINEYARD AVE	90016	10	123B181  1428	5057009019	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Expired	07/23/2018 12:00:00 AM	ADDRESS	34.0304	-118.34519	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(8)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB# PVI-3.0-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27211	08041-10003-23153	1200 S CLUB VIEW DR 1-35	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			07/20/2010 12:00:00 AM			PC Approved	09/01/2010 12:00:00 AM	ADDRESS	34.06748	-118.42481	Changes to the approved plans.  22 Story Condo building. Delta 10 Changes. Plan Check is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27212	13041-10000-04898	2675 N BASIL LANE	90077	5	156B149    58	4379005***	RE15-1-H-RPD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.12094	-118.44882	PV1 6.54KW TWO  STORY roof-mount. transformerless system.20 MOD:SUNPOWER SPR-327NE-WHT-D. INV: SPR-6000P-TL-1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27213	17041-20001-32373	11419 N MONTALCINO WAY	91326	12	213B109   412	2701068023	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM			PC Approved	10/05/2017 12:00:00 AM	ADDRESS	34.27907	-118.58671	EXPEDITED PER APPLICANTS REQUEST.ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.5 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27214	18041-10000-37007	14701 W RINALDI ST	91340	7	213B149   125	2612015011	C2-1-CPIO	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.28099	-118.45337	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27215	19041-10000-43290	9707 N WOODLEY AVE	91343	12	201B141   358	2677014001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.24674	-118.48519	Plan check for a PV1 5kW AC / 6KW DC roofmounted system. Scope includes (1) inverter, (21) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27216	15041-20000-44041	1254 W YOSEMITE DR	90041	14	160-5A229 292	5480020009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Expired	03/05/2018 12:00:00 AM	ADDRESS	34.13323	-118.19322	Plan check for a PV1 roof-mounted PV system. System size is 1.3 kWac and consists of (6) micro-inverters and (6) modules. Project site is a duplex; each house is getting its own PV system.Note: PV system for 1252 Yosemite Drive can be found under 15041-20000-44033	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27217	13041-20000-06416	1380 N SUMMITRIDGE PL	90210	5	144B157    44	4355007040	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2013 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.09484	-118.41992	photovoltaic system on roof of new remodeled single family dwelling.  Location was approved by the fire department.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27218	15041-20000-13675	6250 N TOPANGA CANYON BLVD BldgF#1530	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for 1st time tenant at Westfield Village at Tapanga(Bldg F #1530) for Credit Union. Total area: 2,000 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27219	13041-10000-00979	380 WORLD WAY Space T55	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	12/21/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 165 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE COFFEE SHOP CONCESSION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27220	18041-10000-04694	6255 W SUNSET BLVD #  640	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	ALTERATIONS IN OFFICE-NEW CIRCUITS AND LUMINAIRESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27221	17041-10000-35545	3500 W WILSHIRE BLVD #105	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.06157	-118.30077	PC for T24 only for new lights for change of use from office to retail TI. Installing new panel panel, lights, receptacles and equipment. Total area of 236sqft. B# 17016-10000-05452.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27222	16041-10000-43633	1801 S GRAND AVE	90015	14	124-5A205 225	5126012019	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.03417	-118.2676	PC FOR T24 ENERGY ONLY. REPLACING OLD LIGHTS FOR NEW LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27223	16041-10001-00578	4201 W WILSHIRE BLVD #400	90010	4	135B189   972	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.06189	-118.31911	Supplemental PC, changes to an approved set.1. Added corridor, total area becomes 24,155sq.ft2. Added light fixtures models, revised qty of light fixtures.Permit under 16041-10000-00578<<TI OF EXISTING OFFICE SPACE 4TH FLOOR. PC FOR ENERGY ONLY, TOTAL AREA 23,775 SQ.FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27224	15041-20000-05899	1569 W 37TH PL	90018	8	117B193   172	5041026017	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.02009	-118.30523	Plan check for a PV1 roof-mounted PV system. System size is 4.3 kWac and consists of (20) modules, (20) micro-inverters and (1) 100-amp rated subpanel.Note: PV plan check over the counter becasue B contractor can not pull permit online.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27225	17041-10000-06297	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.03145	-118.41085	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  186800 SQ FT. (OUTDOOR+ INDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27226	14041-20000-31522	11231 N WHEATLAND AVE	91342	7	210B181    86	2529001030	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.27412	-118.35276	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size: 6kW (3+3). Ungrounded system.23 255W pv modules across 3 strings (7+6 on inv1, 10 on inv2).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27227	17041-10001-37895	634 S MATEO ST	90021	14	124-5A217  44	5164013037	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			Corrections Issued	03/31/2018 12:00:00 AM	ADDRESS	34.03694	-118.23237	Supplemental for significant changes made to master application. Changes inlude change in panel board distribution layout, panelboard re-circuiting and change in lighting layout.B#17016-10000-30380	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27228	13041-10000-09719	4500 W LOS FELIZ BLVD	90027	4	150B197    21	5590003039	[Q]C4-1	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM			PC Approved	04/16/2013 12:00:00 AM	ADDRESS	34.11156	-118.28786	T24 plan check for remodeled basement retail space in 2-story building.  1535 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27229	13041-10000-11302	2103 W 78TH ST	90047	8	099B189   293	6017021024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	33.96919	-118.31579	PV1 - PLAN CHECK FOR NEW 4.578KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING TRANSFORMERLESS INVERTER. PERMIT INCLUDES SERVICE PANEL UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27230	11041-20000-16531	14006 W RIVERSIDE DR 27	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	08/10/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TI RETAIL SPACE #27. PERMIT FOR NEW PANELS, CKTS, XFMR, EQUIPMENT, AND MISC. FOR LOW VOLTAGE WIRING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27231	17041-10000-16093	333 S GRAND AVE 14TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	INTERIOR OFFICE T.I. 11,480SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27232	14041-10000-02007	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Expired	07/26/2017 12:00:00 AM	ADDRESS	34.10158	-118.3062	PV2, Install 81 KW DC roof-mounted solar array on a resturant and surrounding car ports, interconnect with main service panel.(8) Inverters: Fronius IG Plus V 11.4(270 )Modules: Canadian Solar MaxPower CS6X   no fees due to senate 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27233	10041-20000-15881	8963 N BRADLEY AVE	91352	6	195B169   180	2408037017	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM			PC Approved	08/13/2010 12:00:00 AM	ADDRESS	34.23172	-118.37834	energy plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27234	15041-20001-01209	18041 W DEVONSHIRE ST	91326	12	204B125   152	2731010015	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	PIN	34.25766462	-118.52695245	Expedited per customer request.PV2. Install roof mounted PV system sized 15.2 kW. Interconnected with main service panel. (54) CS6X-310P Modules(2) 4600TL Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27235	12041-10000-01466	7351 S LA TIJERA BLVD	90045	11	102B173     1	4104005018	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM			PC Approved	01/20/2012 12:00:00 AM	ADDRESS	33.97124	-118.37899	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR AUTO REPAIR SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27236	15041-20000-42196	7307 S HOBART BLVD	90047	8	102B193  1605	6018001018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	33.9734	-118.30798	Plan check for PV roof mounted system. System size: 1.9kWac with 9 modules and 1inverter (3.8kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27237	13041-10000-00511	865 N SANBORN AVE 4-11	90029	13	144A201   301	5427004005	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	Apartment			01/08/2013 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	34.0879	-118.284	fire alarm system for 3 story appartment. new building. 1 pannel 39 devices.865 sanbom units 4-11914 n hoover units 1-3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27238	17041-20000-14940	7080 W HOLLYWOOD BLVD SUITE 100	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.10134	-118.34445	PLAN CHECK FOR ENERGY 2016. TENANT IMPROVEMENT FOR IGNITED SPACES. BUILDING CONNECTED TO HIGHRISE. SCOPE OF WORK IN THE FORST FLOOR ONLY. PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-20000-13373.THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27239	08041-10001-11235	5151 W WILSHIRE BLVD	90036	4	135B181   919	5507022016	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	34.06244	-118.34233	MODIFICATION TO AN APPROVED SET OF PLANS.  REMOVING THE TIME CLOCK AND INSTALLING OCCUPANCY SENSORS THROUGH OUT THE BASEMENT, 2ND, 3RD, AND 4TH FLOOR.  <<<<<<Methane Zone.  Plan check power and energy for new BMW car service center. 4 story with basement.>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27240	13041-20000-24868	1448 S WESTWOOD BLVD	90024	5	132B153   918	4325019023	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.0545	-118.44083	t24 for storage space. pc for energy only. total area 4.2 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27241	18041-10000-20327	7843 N LANKERSHIM BLVD Suite #102	91605	6	189B169   517	2310025034	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	First time occupance of a new office space in Suite #102 on the first floor. Full plan check for power and energy. BUILDING PERMIT # 16016-10000-30872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27242	17041-20000-23465	350 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A203 152	5111003038	[Q]M1-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Closed	06/29/2020 12:00:00 AM	ADDRESS	34.01092	-118.27958	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 5000 AMPS. ALL LOADS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27243	18041-30001-08076	16531 W GREENLEAF ST	91436	5	168B137   461	2284005022	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM			Re-Activate Permit	10/23/2018 12:00:00 AM	ADDRESS	34.15605	-118.49339	04/12/2018 Changes to an approved set of plans. System size has been reduced to 9 kWac and module count has remained the same. One of the load centers has been removed.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 10.45 kWac and consists of (2) inverters, (29) modules, (3) load centers, and (2) PowerWalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27244	10041-20000-12378	6290 W SUNSET BLVD UNIT C	90028	13	147A189   227	5546025027	(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	ADDRESS	34.09777	-118.32646	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT RESTAURANT (BURGER LA).  BUILDING ELECTRICAL CORE & SHELL UNDER #08041-10000-01158	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27245	11041-20000-13239	612 W 35TH PL	90089	9	118-5A201   5	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM			PC Approved	06/24/2011 12:00:00 AM	ADDRESS	34.0199	-118.28239	energy plan check bathroom remodel 7 floors	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27246	19041-20000-49217	6650 N VAN NUYS BLVD	91405	6	180B149   241	2237001010	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.19215	-118.44845	TI to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only. Affected area: 5676 SFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27247	15041-20000-24087	28114 S WESTERN AVE Unit #3	90732	15	024B193     4	7442030206	P-1XL, [Q]C2-1XL, [Q]C4-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	33.76399	-118.31018	TI to eixisting commercial building. Change of use from retail to veterinarian clinic. Plan check for power and energy. Adding new lighting including emergency.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27248	10041-10000-04112	6340 W HOLLYWOOD BLVD	90028	13	148-5A187 166	5546009026	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/08/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	06/15/2010 12:00:00 AM	ADDRESS	34.10145	-118.32796	Title 24 and emergency lighting for a two story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27249	19041-20000-46695	17953 W MEDLEY DR	91316	5	165B125   145	2184036027	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.14996	-118.52527	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 20.15 KW DC/15.2 KW AC. SCOPE OF WORK CONSISTS OF (62) PV MODULES WITH OPTIMIZERS AND (2) 7.6 KW INVERTERS AND A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27250	15041-20000-35596	2129 N EASTLAKE AVE	90031	1	136-5A223  32	5210028002	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.07	-118.20788	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.3 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27251	16041-20000-07539	5446 N NEWCASTLE AVE	91316	5	174B129   974	2162009191	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Expired	04/20/2018 12:00:00 AM	ADDRESS	34.16989	-118.5242	Plan check for a PV2 roof-mounted PV system. System size 11 kWac and consists of (1) inverter, (48) modules, and (1) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27252	13041-20001-23185	12168 N YOUNGDALE AVE	91342	7	216B149   102	2611020002	RS-1	North Valley	Sylmar	Sylmar	YES	1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.29158	-118.45757	New 12.25kw Roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED.  Plan check and permit are for the PV system only, NOT for main service upgrade or derating of main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27253	13041-10000-02020	500 S VIRGIL AVE SUITE 305	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.06492	-118.28687	4 STORY MEDICAL OFFICE BUILDING.  BUILDING OCCUPANCY CHANGED FROM OFFICE TO MEDICAL, FIRST TIME TENANT IN SUITE 305 UNDER NEW OCCUPANCY.  POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27254	15041-10000-33362	550 S HOPE ST 11TH	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Expired	11/09/2017 12:00:00 AM	ADDRESS	34.04989	-118.25574	T-24, TI  TO AN OFFICE SPACE IN THE 11TH FLOOR ON AN (E) HIGH RISE BUILDING. ELECTRICAL PANELS TO REMAIN, NEW LIGHTING AND RECEPTACLE CIRCUITS TO A PORTION OF THE FLOOR. TOTAL SQ. FT. 1452.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27255	14041-20000-04980	16844 W FLANDERS ST	91344	12	213B133   614	2610005018	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Closed	03/30/2016 12:00:00 AM	ADDRESS	34.27997	-118.49947	pv1 single family dwelling. total system size 6kw ac using transformerless inverter nonstandard plan. using power optiomizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27256	14041-10000-14515	1149 S HILL ST 5TH FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Expired	07/14/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	TENANT IMPROVEMENT IN OFFICES OF USC SCHOOL OF SOCIAL WORKPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27257	19041-20000-17272	11963 N RICASOLI WAY	91326	12	216B109   336	2701085017	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.29049	-118.58494	PLAN CHECK FOR NEW PV AND ESS FOR EXISTING SFD. PV SYSTEM SIZE IS 6.93KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (22) HANWHA Q CELL PV MODULES, (1) 7.6 DELTA SOLIVIAINVERTER, (1) 13.5KWH TESLA POWERWALL, AND A 200A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27258	15041-10000-06099	633 W 5TH ST	90071	14	130-5A209 152	5151017028	C5-4D, [Q]R3-1	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PNELS.  SCOPE OF WORK IN FLOOR 1 AND 2.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 12275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27259	17041-10001-09168	6904 S LA TIJERA BLVD	90045	11	102B173   202	4103010004	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	33.97579	-118.37323	PC FOR DELTA B CHANGES AS NOTED ON PLANS. NEW CEILING LAYOUT, UPDATED T24. POWER REVIONS AS WELL. THIS IS PC ONLY. PERMIT UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27260	13041-20000-21922	21717-21721 W DEVONSHIRE ST	91311	12	204B105   245	2722015002	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.25741	-118.60232	RENOVATION OF FIRE DAMAGED BUILDING. NEW LOAD LESS THATN 400A. PC FOR T24 ENERGY ONLY. TOTAL AREA OF RENOVATION 1664 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27261	18041-10000-33871	8230 N HASKELL AVE	91406	6	192B141   502	2673022045	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			Reviewed by Supervisor	09/13/2018 12:00:00 AM	ADDRESS	34.22014	-118.47475	PLAN CHECK FOR SERVICE UPGRADE FROM 800A TO 1200A 480/277V - SCOPE INCLUDES ALL NEW FEEDERS AND APPROX. 340A OF NEW CONNECTED LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27262	15041-10000-05245	19550 W NORDHOFF ST	91324	12	195B117     9	2783028062	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.23529	-118.55947	A new car wash building supplied from outdoor feeder; total area is 1304 SQ feet.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27263	19041-10000-37330	871 S TREMAINE AVE	90005	4	132B185   341	5090001012	R1V3-RG	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM			Reviewed by Supervisor	09/26/2019 12:00:00 AM	ADDRESS	34.05884	-118.33675	[EPLAN] PLAN CHECK FOR 10KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 36 MODULES USING P400 OPTIMIZERS CONNECTED TO EXISTING 200A SERVICE. DERATED MAIN BREAKER SHALL BE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27264	17041-10000-21149	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	PC for new 106 devices and 4 new RPS panels to existing fire alarm system in 3rd and 4th floor of building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27265	14041-20000-04506	14723 W ADDISON ST	91403	4	171A149   295	2263031052	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.16135	-118.45378	New roof mounted PV system with 5.6 KWdc, Microinverter (Enphase M215 model).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27266	13041-20000-02913	15821 W VENTURA BLVD	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.15584	-118.47812	New wall partitions to create new offices.  Add switches to rooms, relocate lights and receptacles.  PLAN CHECK  ONLY for Energy, Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27267	19041-10000-01178	840 W DOWNEY WAY LJS HALL-2nd flr	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.01997	-118.28717	"T-24 ONLY FOR TI ON THE SECOND FLOOR OF ""LJS Hall"" BUILDING (USC) in Rooms 253 & 264 RESEARCH LABORATORY REMODEL.  SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND EQUIPMENT. TOTAL AFFECTED AREA IS 1,118 SQ.FTB#19016-10000-00421"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27268	12041-20000-23658	10700 W SANTA MONICA BLVD	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.05167	-118.432	plan check for energy only. no emergency lighting. existing bank. 263 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27269	17041-10000-42560	860 E FLORENCE AVE 1-30	90001	9	102B209   105	6023003032	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.01	Electrical	Electrical	Public Safety Only			11/27/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	33.97451	-118.25874	NEW FIRE WARNING SYSTEM FOR 28 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27270	14041-10000-10145	11024 W STRATHMORE DR	90024	5	135B149   462	4363016001	[Q]R4-1VL-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			04/17/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.06471	-118.45062	Plan check for new fire alarm system.  178 devices and 1 fire alarm controll pannel, and 1 announciator pannel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27271	12041-20000-21902	14006 W RIVERSIDE DR #51	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for energy only. Existing emergency lighting. Space 51. 790 sqft.TENANT IMPROVEMENT OF EXISTING RETAIL STORE. NEW STOREFRONT, MILLWORK AND FLOORING. (E) WALLS AND CEILING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27272	15041-20001-15551	4269 N BECK AVE	91604	2	165B169   688	2365026022	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM			PC Approved	07/02/2015 12:00:00 AM	ADDRESS	34.14694	-118.38348	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 10.7 kWac.  Central inverter system with 2 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27273	14041-10000-05577	3560 S WATT WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.02169	-118.28671	REPLACING OF THE FIRE ALARM CONTROL PANEL ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27274	19041-10000-09180	19191 S VERMONT AVE -3rd Floor	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC for High rise, T-24 only. scope of work is in the 3rd floor includes corridors , elevator lobbies and restrooms. area of scope 2454sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27275	17041-10002-11390	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.10222	-118.32701	CHANGES TO AN APPROVED SET OF PLAN AS FOLLOWS. SERVICE UPGRADE FROM 2000A TO 2500A - SWITCHGEAR SERCTION UPGRADE AND RELACATION UPGRADE FROM SWITCHGEAR TO ELECTRICAL ROOM - NEW FAULT CURRENT REPORT PROVIDED ON PLAN FULL PLAN CHECK INTERIOR AND EXTERIOR RENOVATION FROM GROUND FLOOR (1) TO ROOF (6) FOR EXISTING  HOTEL, NO CHANGE IN USE. EXISTING 2000 AMP SERVICE 120/208V 3PHASE 4WIRE. NEW DISTRIBUTION BOARDS BEING ADDED, NEW PANELS. 5 TYPICAL UNITS. NEW INDOOR/OUTDOOR LIGHTING. PANELS. AREA: 36,440. BLDG # 17016-10000-08652.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27276	16041-10000-10101	5990 N SEPULVEDA BLVD #450	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.17911	-118.46588	T-24, TI REMODEL TO THE 4TH FLOOR, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4997.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27277	13041-10000-21043	102-116 W 5TH ST	90013	14	129A211   155	5149037010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Expired	09/25/2015 12:00:00 AM	ADDRESS	34.04673	-118.2488	"FIRE ALARM TO 13 STORY HOTEL. ""COMPLY WITH DEPARTMENT ORDER effective date07/11/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27278	18041-20002-23612	10073 W MCBROOM ST	91040	7	207B181    55	2543008012	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM			PC Approved	08/24/2018 12:00:00 AM	ADDRESS	34.26391	-118.35048	8/24/2018changes to an approved set of plans.  changes to relocate service equipment.this is plan check only.((((Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWac and consists of (42) AC PV modules and (1) load center.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27279	19041-30000-50021	22301 W NEEDLES ST	91311	12	201B101   324	2727006038	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	08/18/2020 12:00:00 AM	ADDRESS	34.2467	-118.61298	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 11.4KWac/12.2KWdc. SCOPE OF WORK IS 39 MODULES (SC STD SC315B2) WITH OPTIMIZERS (SE P400), A CENTRAL INVERTER (SE11400H-US). NOTE MPU TO BE PULLED UNDER SEPERATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27280	16041-10000-09604	1962 E CESAR E CHAVEZ AVE	90033	14	129A223    72	5183001900	PF-1XL	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.04913	-118.21344	PC FOR REPLACEMENT OF FA SYSTEM. NEW PANEL AND 66 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27281	17041-20000-04974	17265 W WESTBURY DR	91344	12	219B133   233	2608007002	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.29865	-118.50953	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (19) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27282	17041-10002-03661	9151 S FALMOUTH AVE	90293	11	093B153    73	4118013915	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	08/19/2021 12:00:00 AM	ADDRESS	33.95302	-118.43391	PLAN CHECK FOR LOST SET OF PLANS - PLAN CHECK FOR TITLE 24 ONLY ORIGINAL PERMIT PC FOR T24 ENERGY ONLY FOR BLOWER ROOM. 3 NEW LIGHTSPlan Check ONLY. Permit Issued under: 17041-10001-03661	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27283	10041-10000-14076	12223 W VENTURA BLVD	91604	2	162B165    31	2367017015	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	34.14351	-118.39919	T.I. to existing building (Bank of America).  Install general and emergy lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27284	13041-20000-24626	5903 N SHOSHONE AVE PV-1	91316	5	177B129   868	2254003013	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.17756	-118.51673	PV-1. Plan check for microinverter standard plan, 18 inverters for 3.87kW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27285	18041-10000-34714	6553 N HASKELL AVE	91406	6	180B141   432	2233003060	RD1.5-1-RIO, [Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	Apartment			09/11/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.1902	-118.47516	PV2. New solar system on existing commercial roof-top. Total system size is 16.17KWdc / 15.0KWac with (64) modules, and (1) inverters interconncting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27286	12041-10000-08139	555 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	ADDRESS	34.13776	-118.3584	PLAN CHECK T24 OUTDOOR ENERGY FOR NEW STEEL CANOPY OVER EXTERIOR ACCESSIBLE PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27287	15041-20000-16945	10250 W CONSTELLATION BLVD 10th floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	Title 24 plan check only.  Total area = 11,638 sq. ft.  T.I. to existing commercial office highrise.  New lighting and recepticles (<400 A load)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27288	19041-10002-08992	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM			Ready to Issue	08/21/2019 12:00:00 AM	ADDRESS	34.18421	-118.60617	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 11(BULLITIN 4). CHANGES INCLUDE REVISING KITCHEN FLOOR PLANS,  ADDING/REMOVING RECEPTACLES, REVISING FLOOR PLANS, AND REVISING PANEL SCHEDULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27289	12041-10000-26750	12210 W VENICE BLVD	90066	11	114B157  1487	4235023002	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.00456	-118.4314	PLAN CHECK FOR ENERGY. TI TO EXISTING MARKET/DELI. 1 STORY + MEZZANINE. 7858 SF. NEW ENGINEER. PLANS MODIFIED FROM APPROVED 10041-20000-12677	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27290	16041-20000-10790	5700 W WILSHIRE BLVD Suite 265	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.06218	-118.35303	Plan check for energy only. TI to existing office space in high rise building. New lighting (incl. emergency) and receptacles. 3,337sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27291	13041-10001-12569	3119 N DONA ELENA PL	91604	2	156B169   146	2381025009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM			PC Approved	09/06/2013 12:00:00 AM	ADDRESS	34.1268	-118.38362	"][][CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGES ARE FOR THE REPLACEMENT OF 3/4"" CONDUIT FROM JBOX TO INVERTERS 2 & 3 WITH A LARGER CONDUIT 1 1/4"", PER INSPECTOR REQUEST [][][][PV1 18.13KW NONSTD ROOFMOUNT. XFMRLESS. solaredge se6000A-us (1) and se5000A-US (2x) . also trina solar TSM-245PC05 (74 modules)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27292	19041-20000-03988	10536 W GARWOOD PL	90024	5	135B153   143	4360020014	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			Corrections Issued	02/01/2019 12:00:00 AM	ADDRESS	34.06808	-118.43489	Plan check for PV roof mounted system, system sizea: 14.0KW DC, 13.86KW AC CEC with 45 PV Modules and 1 inverter(11.4KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27293	17041-10001-22472	3527 N CAMINO DE LA CUMBRE	91423	4	159B149   181	2274021006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.13484	-118.44697	Expedite fees only       Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 14.061 kWac.  AC module system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27294	16041-10000-39505	725 S FLOWER ST	90017	14	129A209    86	5144010017	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	11/07/2020 12:00:00 AM	ADDRESS	34.04814	-118.25952	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27295	13041-20001-26892	11651 W SAN VICENTE BLVD	90049	11	132B145   503	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Issued	01/02/2014 12:00:00 AM	ADDRESS	34.05412	-118.46401	PC FOR POWER AND ENERGY. RESTAURANT REMODEL. GREATER THEN 400A LOAD. (plan check for addition of patio heaters. all changes clouded. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27296	18041-10000-03308	1801 N HILLHURST AVE	90027	4	150B197  1085	5590019024	P-1	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.10395	-118.28757	PC for T24 only for new lighting for office TI. Installing new lights and receptacles. Total area 6510 sqft. Master permit under 17041-90000-46638B# 17016-10000-27323.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27297	14041-20003-25864	7625 N VAN NUYS BLVD	91405	6	186B149   109	2210031001	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.20911	-118.44904	"Change of gas water heaters to electric.  Plan check for power.   Delta 3 revisions only.  (((ADDITION OF  30'-2"" x 99'-6"" OFFICE USE,  CHANGE PORTION OF (E) RETAIL TO MEDICAL OFFICE, (30' X 85').   NEW 1000A SERVICE AND PANELS FOR VACANT SPACES.  ))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27298	15041-10001-14248	6500 N CANOGA AVE	91303	3	180B105    74	2148031018	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	03/16/2016 12:00:00 AM	ADDRESS	34.1887	-118.59717	TI-24 TO (E) COMMERCIAL BUILDING, RETAIL. ADDING NEW LIGHTING. TOTAL SQ. FT. 24284* SUPPLEMENTAL TO REPLACE LOST DRAWING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27299	19041-20000-36622	22100 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.1863	-118.6083	PV2.  Plan check for PV roof mounted system, System size: 33.06KW DC, 29.5KW AC with 76 PV Modules and 2 inverter(14.4KW )Note: This is 12 buildings on 1 Plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27300	18041-20000-31719	6224 N WOODLAKE AVE	91367	3	177B093   260	2039010021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.1835	-118.6313	Plan check for PV roof mounted system, system size: 7.6kW with 28 modules and 1 inverter(7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27301	19041-20000-47077	3123 S LIVONIA AVE 1-29	90034	5	123B169   976	4311027012	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM			PC Info Complete	09/30/2021 12:00:00 AM	ADDRESS	34.0319	-118.39194	ADD NEW 800 AMP SERVICE, PROVIDE PANELS, EQUIPMENTS AND TITLE-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27302	18041-20000-31088	5900 W WILSHIRE BLVD #120	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for Title 24 Energy only in existing high-rise building T.I. office space. Total area: 428 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27303	16041-20000-25713	5735 W 96TH ST	90045	11	093B169   145	4125021008	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Info Complete	11/09/2016 12:00:00 AM	ADDRESS	33.94955	-118.38172	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVENET FOR NEUTROGENA MANUFACTURING. ( 2 OF 3 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27304	15041-20000-07043	7748 N GRAYSTONE DR	91304	12	189B089   287	2017027009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Expired	04/19/2017 12:00:00 AM	ADDRESS	34.21242	-118.65403	PV1 SFD TOTAL SYSTEM SIZE 12.2KW AC USING TOTAL OF 3 INVERTERS AND 64 SOLAR MODULES. TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. ROOF MOUNTED.NOTE: Fee is $0.00 due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27305	12041-20000-18499	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.06371	-118.3703	Install new emergency generator and panels and ATS to serve the 23rd floor of the building.  Plan check for power.  The location of equipment is on levels P1, P2, the 23rd floor, and on the roof.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27306	18041-30000-34703	2110 S COTNER AVE	90025	5	126B153   732	4322025035	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.04039	-118.44011	PLAN CHECK FOR T24 ONLY, TOTAL AREA UNDER THE SCOPE: 2,037SQ.FT. SCOPE INLUDES: EXPAND, REMODEL & CONVERT EXISTING MEZZANINE FLR TO 2ND FLR OFFICE/EMPLOYEE LOUNGE & FILE/STORAGE RMS WITHIN EXISTING  AUTO REPAIR SHOP W/ OFFICE. EXPAND EX 1ST FLR OFFICE TO INCLUDE CUSTOMER LOUNGE ROOM, NEW HANDICAP RESTROOMS & PARTS COUNTER. THIS PERMIT TO INCLUDE RESTRIPING OF EX PARKING LOT. SEE COMMENTS.(B# 16014-20000-00882)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27307	19041-10000-08009	1661 W 240TH ST	90710	15	042B193   713	7439007033	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	04/20/2020 12:00:00 AM		Permit Finaled	03/09/2021 12:00:00 AM	ADDRESS	33.80741	-118.3065	NOTE: PERMIT FEES ARE $0 DUE TO AB 1414.PV2, NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 714KWdc / 566.1KWac.(1785)MODULES-LG 400N2W-V5(5)INVERTERS-SOLAREDGE TECHOLOGIES LTD SE 99.9K-US(1)INVERTER- SE 66.6K-US   Note:this project is a second phase for the pv system. All service and switchgear is under 1st phase with the application #: 19041-10000-07987	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27308	15041-20000-42462	15826 W VENTURA BLVD	91436	5	168B141   641	2283009002	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.15544	-118.47848	Plan check for Title 24 only in existing restaurant T.I Dickey's Barbecue Pit. Total area: 1,292 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27309	13041-10000-10979	6600 N TOPANGA CANYON BLVD ELEC RM-TO STE 51	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	REPLACEMENT OF 400 A SERVICE TO 1200A (EQUIPMENT OVER 600A) FOR WESTFIELD MALL.  WORK FROM BASEMENT LEVEL ELECTRICAL ROOM TO A TENANT ON SUITE #51.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27310	11041-20000-23087	1239 S ABBOT KINNEY BLVD	90291	11	108B145  1148	4239022029	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00, 2735.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	33.99137	-118.46835	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENTS NEW RESTAURANT. NEW 800A SERVICE SERVING TWO BUILDINGS AND EQUIPMENT. BUILDING LOCATED IN METHANE ZONE. (NORTH BUILDING). THE SOUTH BUILDING UNDER SEPERATE PERMIT #12041-20000-06843	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27311	14041-20000-02225	6300 N CANOGA AVE SUITE 1350	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.18492	-118.59722	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON SUITE 1350W	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27312	15041-20001-35661	4421 N NOGALES DR	91356	3	168B121   569	2177009016	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	34.15263	-118.54618	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size 13.0kW and  43 modules}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27313	15041-10002-13263	15927 W VENTURA BLVD	91436	5	168B141   544	2261021007	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM			PC Approved	09/30/2016 12:00:00 AM	ADDRESS	34.15615	-118.48017	09/30/2016, Changes to the approved set of plans. Consolidating load on to the panel L and remove panel D1. removed all track ligthing and addition of LED lights instead.. changes under delta 4, Plan check only.<<<INSPECTOR TO HAVE APPLICANT SUBMIT FOR FULL PLAN CHECK FOR PLACE OF ASSEMBLYALTERATIONS IN EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24 with new lighting and receptacles. Permit is paid under original permit. # 15041-10000-02568.  note: customer did not want to have supplimental permit under original application due to alot of changes on the lighting plan.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27314	10041-10001-17533	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM			Corrections Issued	02/13/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	Replace an existing damaged 3000 Amp Service Equipment.  Feeders are changed with the values, switch gear is new, some loads are different.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27315	19041-10000-16382	19015 W PARTHENIA ST	91324	12	195B121   346	2784003056	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.22837	-118.54743	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27316	14041-20000-21974	1080 S LA CIENEGA BLVD	90035	5	132B173   684	5087001038	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.05713	-118.37597	Plan check for title 24 only on new restaurant. total working area is 617 SQ feet. Plan check is based on 2008 energy code, building permit submited before July 1st.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27317	11041-10000-17287	1699 W CARSON ST	90501	15	051B193   909	7349033044	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	33.83167	-118.30884	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK IS FOR ENERGY ONLY.  PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27318	14041-10000-33836	14111 W RIVERSIDE DR	91423	4	168B153   407	2248024015	[Q]C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	33.9787	-118.31759	Title 24 plan check only.  Total area = 179 sq. ft.T.I. to existing bank.  Converting a cubicle to office.  Installation of 5 new lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27319	13041-10000-06029	1333 N WATERLOO ST	90026	13	141A207   127	5424023005	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			03/07/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.08138	-118.26534	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. THIS APPLICATION IS PART OF A SERIES OF 3 APPLICATIONS. TOTAL SYSTEM SIZE 1.68 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27320	15041-10000-02773	5955 N LANKERSHIM BLVD	91601	2	177B169   914	2338009018	RD2-1, [T][Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.17886	-118.3833	Plan check for new 600Amp meter/disconnect section installed on outside of building to refeed existing tenant in other building. The run from UGPS to new section is not exposed and is protected per applicant subject to field inspector.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27321	19041-10001-01861	1101 S HARBOR VIEW AVE	90732	15	015B193   956	7459003014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	33.73448	-118.30888	**Expedited fe per applicant**New Rooftop solar system with ESS on (E) SFD, System size at 7.6 kW AC, battery size at 9.8 kWh. Install (5) modules are installed on the main house, and (7) modules are installed on the detached garage, total (12) modules with (12) P320; (1) 7.6 kW AC inverter; (1) ESS system at 9.8 kWh; (1) 125A load center. System interconnect to (E) 200A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27322	13041-10002-35064	1801 S FIGUEROA ST	90015	9	124-5A205 282	5126002009	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.03524	-118.27179	Change to aapproved set by relocating the heat pump units and adding (2) circuits) on the floor plan; Note. all changes are under delta-B only.((11/21/2014 - Sup. application for changes to approved set.  Change is location of some walls to accomidate larger conference room and restrooms resulting in changes to lighting and recepticle location.))PLAN CHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION AND REMODELING OF VEHICLE SERVICE FACILITY; PARTS STORAGE AND OFFICES AND THREE LEVELS OF PARKING AND A ROOFTOP PARKING DECKBUILDING PC # 13010-10000-04076	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27323	18041-10000-12866	1301 S OCEAN FRONT WALK #17	90291	11	108A143   398	4226006001	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM			PC Info Complete	04/10/2018 12:00:00 AM	ADDRESS	33.98842	-118.47485	TI IN AN EXISTING RESTUARANT. EPC FOR POWER AND ENERGY.PERMIT WAS ISSUED ON 18041-10000-08510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27324	18041-20000-16392	14852 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.29441	-118.4548	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27325	19041-10000-38883	215 E ROSE AVE	90291	11	111B141   658	4286003008	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	33.99645	-118.47757	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI IN AN EXISTING OFFICE SPACE, SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 5505 SQFT. B#: 19016-10000-26002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27326	13041-10000-26278	11601 W WILSHIRE BLVD #1920	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	REMODELING OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27327	15041-20000-03282	19959 W INGOMAR ST	91306	3	189B113   988	2106004029	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.21205	-118.5685	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN. SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27328	19041-20000-20742	19331 W OXNARD ST	91356	3	177B117   639	2153035016	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.17943	-118.55466	Plan check for PV roof mounted system, PV system size: 16.8KW DC, 11.4KW AC with 48 PV Modules and 1 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27329	19041-10000-17858	4515 N EAGLE ROCK BLVD	90041	14	157-5A221  80	5473037007	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	09/30/2020 12:00:00 AM	ADDRESS	34.12659	-118.219	PC FOR POWER AND ENERGY(LOT 1-12). SCOPE INCLUDES A NEW 1200A SERVICE FOR 12 SFD AND COMMERCIAL SPACES. TOTAL AFFECTED AREA IS 42118 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27330	14041-10000-30841	18001 S FIGUEROA ST ste E	90248	15	063B201   174	7339008001	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	33.86778	-118.28182	Engergy plan check for commercial building for replace HID light to  New Flourescent fixture	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27331	19041-20000-51873	12630 N JIMENO AVE	91344	12	219B133   130	2602021017	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	04/19/2020 12:00:00 AM	ADDRESS	34.29995	-118.50312	INSTALL (1) NEW TESLA POWERWALL ON EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27332	16041-20000-37465	7855 N LINDLEY AVE	91335	12	189B125   558	2102017058	(T)R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.2134	-118.52751	Plan check for the installation of a solar pv system, roof-mounted on a church building and school building. 36kW ungrounded system [3*12kW]. (128) pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27333	15041-20000-29548	8425 N BURNET AVE #6	91343	6	192B145   290	2654025***	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Expired	10/03/2017 12:00:00 AM	ADDRESS	34.22352	-118.46359	Plan check for PV roof mounted system. System size: 6.0kW with 30 modules and 1 inverter(5.0kW). Standard plan is being  use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27334	12041-10000-24068	2489 W WASHINGTON BLVD	90019	10	126B189   886	5073024002	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	04/24/2013 12:00:00 AM	PIN	34.04024142	-118.31746554	Change to lighting to an existing retail store on the first floor.  Load is less than 400Amps.  PLAN CHECK ONLY for Energy, no emergency lighting. Permit fees are under inspection. Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 03/06/2012. CEIS Case Number is 448849.Payment of investigation fee due at time of permit issuance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27335	17041-10000-04762	2401 W PICO BLVD	90006	1	129B197  1055	5076019902	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.04743	-118.28936	CHANGING OUT OLD FIXTURES FOR MORE ENERGY EFFICIENT. PC FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA IS 25775 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27336	19041-10000-03645	150 N SOTO ST	90033	14	127-5A223  77	5180002025	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			01/30/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.04488	-118.20883	PLAN CHECK FOR POWER ONLY. CONVERTING EXISTING 61 GUESTROOMS TO LIGHT HOUSE-KEEPING. SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS EQUIPMENT ON AN EXISTING 800A DISTRIBUTION SYSTEM. NEW CIRCUITS ARE FOR RANGES, WASHERS AND DRYERS UNITS. ONE NEW LIGHT FIXTURE FOR ONE COMMON AREA BATHROOM. TOTAL CONNECTED LOAD OVER 400AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27337	19041-10000-45091	200 BAUCHET ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	12/01/2020 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM				PC FOR ENERGY ONLY. SCOPE INCLUDES NEW INDOOR AND OUTDOOR LIGHTS FOR AN EXISTING SPACE. TOTAL AFFECTED AREA IS 833 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27338	17041-10001-08805	1109 N VIRGIL AVE	90029	13	145-5A201 479	5542026037	C2-1D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Info Complete	07/03/2017 12:00:00 AM	ADDRESS	34.09117	-118.28682	Supplemental for changes to approved set.  Service size increased from 400 amps to 600 amps. All changes are clouded under delta 2. Master application was plan checked for Title 24 only.   Plan check for power only.  Change of use from manufacture to office space.Note: Permit will be pulled under PCIS#17041-10000-08805	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27339	19041-10000-28952	2911 W EXPOSITION PL Units5	90018	10	117B185  1312	5044011026	CM-1-SP, RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02047	-118.32807	Plan check for a PV2 3.00kw AC / 2.6KW DC  roofmounted system with (1) inverter and  (8) modules interconnecting through the main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27340	15041-20002-10109	1580 W 36TH ST	90018	8	120B193  1269	5041016019	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM			PC Approved	05/06/2015 12:00:00 AM	ADDRESS	34.0227	-118.30548	Plan check change to approved set of plan. Changes to the layout of the modules{{{{{Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (21) modules. Standard plan is not being used.}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27341	17041-20000-06861	21250 W CALIFA ST 106b	91367	3	174B105    16	2149002018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM			PC Info Complete	03/02/2017 12:00:00 AM	ADDRESS	34.1769	-118.59414	ti to an existing commercial space.  adding new lighting new controls to new panels.  total connected load less than 400 amps.  plan check for energy only. total square footage 3279.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27342	13041-10000-11042	4554 N EAGLE ROCK BLVD	90041	14	157-5A221  65	5474004037	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	ADDRESS	34.12724	-118.21777	Change of use from retail to bakery.  1326 sq ft.  Single story bldg.  Title 24 plan check only.  New 400A service, < 400 A new connected load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27343	18041-10000-06409	5435 N YARMOUTH AVE	91316	5	174B129   999	2162010***	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	02/01/2024 12:00:00 AM	ADDRESS	34.16959	-118.52046	PC FOR ROOF MOUNTED PV ON APARTMENT BUILDING. TOTAL SYSTEM SIZE 14.82KWDC/13KWAC.SCOPE INCLUDES 52 MODULES (285W) WITH 52 MICROINVERTERS (250W)  AND NEW LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27344	11041-10000-17915	7234 N VARNA AVE	91605	2	186B157   619	2328028009	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	ADDRESS	34.20216	-118.42458	PLAN CHECK FOR T-24 ENERGY COMPLIANCE.  NO PERMIT TO BE ISSUED ON THIS APPLICATION NUMBER. SEE PRIVIOUS PERMIT NUMBER 11041-10003-13692.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27345	15041-10000-04621	2300 E PACIFIC COAST HWY	90744	15	033B217     3	7428008905	M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	33.79043	-118.22853	plan check for power only. PROJECT - PHASE 1A WORK PER NABIL: VAPORIZER UPGRADE. Placing following equipment in proper location and intall proper GEC for all the new equipment including Two new standby generators, three new mcc(s) , and miscellaneous electrical (relocating conduits, grounding, security camera relocation). Other types of equipment are provided only as reference for load calculations.  Scope of work is indicated by yellow highlighting on cover sheet.phase 2 to cover electrical connections and installation of the rest of the equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27346	14041-10002-13131	17401 W VENTURA BLVD B17	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM			Corrections Issued	07/16/2014 12:00:00 AM	ADDRESS	34.16136	-118.51189	Title 24 plan check only.  Total area = 2,120 sq. ft.TI to existing commercial space.  Building permit submitted before title 24 part 6 start date.  Electrical permit was already issued at express permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27347	11041-10000-27091	600 W WORLD WAY Term  6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/20/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	installation of a baggage conveyor system at Alaska Airlines Terminal at LAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27348	12041-10000-10643	2970 W OLYMPIC BLVD #301	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	Plan check power and energy for new medical office, first-time tenant. Suite #301. Not check for OSHPD 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27349	13041-10000-25123	1425 N NAUD ST	90012	1	136-5A217 155	5409004012	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM				PV2.  Install 37.8 kW DC roof-mounted solar array, interconnect with existing building distribution system.  126 Renesola JC300M-24/Abv PV modules, 3 Power-One PVI-10.0-I central inverters, and 1 60A subpanel.per SB1222, the application fee has capped the permit fee at 0$	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27350	16041-20000-13005	7248 1/2 N FULTON AVE	91605	2	186B157   583	2327002015	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.2026	-118.42239	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use to a music studio and tenant improvement. Total lighting area = 2,624 sq. ft.Note: Building permit has been pulled under 16016-10000-00042PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-20000-08375.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27351	19041-20000-38557	5711 N SEPULVEDA BLVD	91411	4	174B145   884	2260010017	CM-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.17435	-118.4665	T24 PLAN CHECK FOR LIGHTS AND OUTLET ONLY FOR A TI REMODEL OF A EXISTING TARGET. TOTAL SQUARE FOOTAGE = 1037 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27352	19041-10000-53556	14964 W RYAN ST	91342	7	222B149   384	2506021006	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.30642	-118.45675	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 22  (REC290TP2) MODULES, 22  (SE P320) POWER OPTIMIZERS, 1 CENTRAL INVERTER (SE S5000H-US),  CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE: 6.38KW DC, 5.00KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27353	10041-10000-19028	1140 S ROBERTSON BLVD UNIT  A	90035	5	132B169   725	4332015018	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM			PC Approved	09/24/2010 12:00:00 AM	ADDRESS	34.05586	-118.38353	CHANGE OF USE EXISTING OFFICE TO MEDICAL OFFICE ;PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27354	19041-20000-45036	11329 W OXNARD ST	91606	2	177B173  1096	2337009034	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Apartment			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.17956	-118.37797	Fire alarm system for (N) building.  (40) devices with FACP and annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27355	12041-10000-27931	18011 W SHERMAN WAY	91335	3	183B125    90	2121004021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.20135	-118.5258	CHURCH. REPLACING THE 800 AMP SWITCHGEAR WITH A NEW 1200 AMP. (service & panels are existing to remain. PV system approved under separate permit)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27356	11041-10000-25150	15232 W FOOTHILL BLVD	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2011 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	02/08/2012 12:00:00 AM	ADDRESS	34.32292	-118.46695	PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27357	14041-20001-16819	1513 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.09851	-118.32696	CHANGE IN LOCATION OF LIGHITING FIXTURES DUE TO CHANGE IN BATHROOM LAY OUT. NO CHANGE IN DENSITY AND LIGHTING LOAD. CHANGE OF CONTROLS. PC ONLY. ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27358	14041-20000-06512	4742 N SEPULVEDA BLVD	91403	4	168B145   532	2264004012	R3-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.15698	-118.46577	NEW FIRE ALARM SYSTEM FOR NEW APARTMENT BUILDING. PLAN CHECK IF FOR 71 DEVICES AND 1 FIRE ALARM CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27359	19041-20000-16685	22135 W ROSCOE BLVD LOT #9	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	Plan check for PV roof mounted system, system size: 2.1KW with 7 PV Modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27360	16041-20000-35132	12925 N BRADLEY AVE	91342	7	222B145   472	2506003017	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.30432	-118.45895	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,979 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27361	14041-20000-35838	8746 N BURNET AVE	91343	6	195B145   695	2654007166	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Apartment			12/30/2014 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.22979	-118.46312	Plan check for power and energy. New 3-story 20-unit apartment building w/800A service. 20 APARTMENT UNITS ARE ON 2ND & 3RD FLOORS, REC ROOM/LOBBY/PARKING GARAGE ARE ON 1ST FLOOR @ GRADE. 24,000 SF. Fire alarm variance is on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27362	18041-20000-01511	14828 W RAYEN ST	91402	6	195B149   279	2653005002	(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.23171	-118.45633	new fire alarm system 45 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27363	11041-10000-26364	2002 N ARGYLE AVE	90068	4	150A189    36	5586004019	R3-1XL	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			12/09/2011 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	09/10/2012 12:00:00 AM	ADDRESS	34.10719	-118.32506	PLAN CHECK FOR 5.7KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27364	16041-10001-14029	10561 W PICO BLVD	90064	5	126B157   249	4315005003	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Info Complete	12/20/2016 12:00:00 AM	ADDRESS	34.04431	-118.42087	PC FOR POWER AND ENERGY. THIS SUPPLEMENTAL IS TO COVER THE ADDITIONAL WORK THAT WAS ADDED TO THIS CONTRACT. FULL BUILD OUT OF TENANT. ADDED 2 PANELS AND 60 CIRCUITS TO ORIGINAL SCOPE OF WORK. THIS PLAN CHECK AND PERMIT WILL BE TO FINISH ORIGINAL APPLICATION AND ADD SCOPE OF WORK.  Permit issued under master application under inspection fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27365	10041-20000-14623	1726 N GOWER ST	90028	13	148-5A189  78	5545002901	R4-2	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Public Safety Only			07/28/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	01/27/2012 12:00:00 AM	ADDRESS	34.10253	-118.32216	Plan check for new fire alarm system for Villas At Gower.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27366	15041-20000-23805	21514 W SATICOY ST	91304	3	186B105   164	2111005005	(T)(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Apartment			07/24/2015 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.20807	-118.59943	Plan check for new building. 29 appartment units. lot area 14,340 sq ft.  PLAN CHECK FOR POWER AND ENERGY.  FA VARIANCE WAS SUBMITTED.Note: Building application filed under 15010-20000-00976	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27367	13041-10000-24761	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Info Complete	09/19/2013 12:00:00 AM	ADDRESS	34.14436	-118.27496	FIRE ALARM UPGRADE. 1 FIRE ALARM PANEL. 140 DEVICES. 2 CIRCUITS. KAISER PERMANENTE. 1 STORY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27368	13041-10000-35352	2485 S ARMACOST AVE	90064	11	120B149   165	4257002011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.02776	-118.44796	PV1, Install 4 kW DC roof-mounted solar array, interconnect with main service panel for a one story house. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27369	18041-10000-03923	11164 N BRADLEY AVE	91331	7	210B157   201	2534003020	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.27311	-118.42254	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27370	13041-10000-22769	3000 W 6TH ST	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM			Verifications in Progress	11/05/2013 12:00:00 AM	PIN	34.06351748	-118.28745252	PV2. ROOF MOUNTED PV INSTALLATION. SYSTEM SIZE: DC RATING 27.54 KW. AC RATING 23.4.  TRANSFORMER INVERTER- NEGATIVELEY GROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27371	19041-10000-44290	11401 N PORTER VALLEY DR	91326	12	213B117   356	2822037015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	34.27819	-118.55187	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 21 MODULES (LG320N1K-A5) , 21 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 5.41KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27372	14041-20000-04683	4330 W SUNSET BLVD	90029	13	145-5A201  13	5429006003	C2-1	Central	Hollywood	Los Feliz		1913.02	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	ADDRESS	34.09512	-118.28377	PLAN CHECK FOR T24 PART 6 ENERGY ONLY FOR COFFEE SHOP ('DINOSAUR COFFEE') ;  PROJECTED INDOOR AREA  APPROX. 1,238 SQ FT  AND SPECIFIC LIGHTING APPLICATION FOR PATIO DINING ON OUTDOOR LIGHTING (APPROX. 260 SQ FT ). SCOPE OF WORK < 400A. WORK ALSO INCLUDES EMERGENCY LIGHTING.BUILDING PERMIT UNDER: 13016-10000-25949	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27373	19041-10000-11388	4142 S CENTINELA AVE	90066	11	111B157  1184	4232011028	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	33.9964	-118.42749	NEW 1,200 AMP, 277/480V SERVICE FOR THE INSTALLATION OF EV CHARGING STATIONS IN BANK OF AMERICA PARKING LOT.  SCOPE INCLUDES INSTALLATION OF  (1) SWITCHBOARD ASSEMBLY (3) 150 KW BTC POWER UNITS  (3) 150 KW BTC DISPENSERS AND (1) LEVEL 2 CHARGER.BUILDING PERMIT# 19020-10000-00861UTILITY COMPANY: EDISON	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27374	16041-10001-12005	19844 W SUPERIOR ST	91311	12	201B113   700	2761021015	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Expired	05/25/2018 12:00:00 AM	ADDRESS	34.24594	-118.56602	CHANGES TO THE APPROVED SET OF PLAN. CHANGING THE LAYOUT OF THE MODULES.permit issued under this application for subpanel and main panel upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27375	12041-10000-23664	560 N WESTERN AVE	90732	15	018B193     7	7446001901	OS-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00, 2964.00	Electrical	Electrical	Public Safety Only			10/03/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	ADDRESS	33.7478	-118.30907	This is rec park, the only changes are, service, and two new distribution boards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27376	16041-20000-20744	11755 W WILSHIRE BLVD #1900	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	PIN	34.04869377	-118.46238681	Plan check for Tile 24 only in existing office building high-rise T.I. . Total area: 3,372 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27377	19041-10000-12432	1006 W 53RD ST	90037	9	108B197   448	5002026001	C2-1L	South Los Angeles	South Los Angeles	Voices		2326.00	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			Verifications in Progress	12/16/2019 12:00:00 AM	ADDRESS	33.99402	-118.29191	PC FOR POWER AND ENERGY UPGRADE SERVICE TO 600 AMP PROVIDE NEW PANELS, EQUIPMENT AND LIGHTS.  BUILDING APPLICATION FOR THE PROJECT B#19016-10000-07682	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27378	15041-20001-36741	2500 N SILVER LAKE TER	90039	4	148-5A207  26	5439019017	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM			PC Approved	11/09/2015 12:00:00 AM	ADDRESS	34.10319	-118.26202	EXPEDITED PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. PV SYSTEM CONNECTED TO A 400A MAIN PANEL.  TOTAL SYSTEM SIZE IS 3KWac. (12)ACM-SUNPOWER X20-250-BLK-B-AC(1) 60A SUBPANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27379	15041-10000-23538	350 S LA CIENEGA BLVD	90048	5	138B173   929	5511033019	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.07227	-118.37625	T24 ONLY. T.I. FOR A  T-MOBILE STORE. TOTAL AREA 3086 SQ FT. B# 15016-10000-13650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27380	12041-10000-17640	11740 W SAN VICENTE BLVD #106	90049	11	129B145    75	4265006074	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.05308	-118.4669	Change to lighting for an existing low-rise office space with classrooms.  Unit #106.   Occupancy load is less than 99 and load is less than 400A.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27381	19041-10000-50725	4206 S LINCOLN BLVD	90292	11	105B153    48	4230001019	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	33.9868	-118.4441	PLAN CHECK FOR FOR TITLE 24. SCOPE OF WORK INCLUDES NEW LIGHTING FIXTURES AND CIRCUITS. TOTAL AFFECTED AREA: 1980 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27382	15041-10000-27087	1329 E 3RD ST	90033	14	127-5A219  42	5172010003	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.04513	-118.22559	PC for enrgy and emergency lighting. TI to an existing bldg adding new lighting new controls to new panels, newly connected load less than 400 amps. Total sq ft = 4841.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27383	14041-20003-04891	14006 W RIVERSIDE DR #270	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	06/17/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	6/17/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta A3. Changes include the removal of F6 fixtures and replacement by F7 fixtures.4/28/2015 Changes to an approved set of plans. Changes include the relocation of receptacle circuits, lighting circuits, and a revised lighting floor plan. All changes have been clouded and marked as Delta A2.*****Previous Work Description*****Change to approve set of plan. Replace the light fixture in the plan to match it in the field. (((((((T.I. to existing building Space #270. Install general/emergency lighting. Plan check for energy only.Note: Permit is under a separate application))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27384	18041-20000-18709	5300 W MELROSE AVE #200	90038	4	141B189   384	5522001007	(Q)M1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.08336	-118.31616	Plan check for Title 24 only. Project site is the 2nd floor of an existing high-rise commercial building. Project scope is a tenant improvement. Total lighting area = 9,869 sq. ft.Note: Building application has been generated under 18016-10000-13790	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27385	09041-20004-22007	440 S VERMONT AVE	90020	13	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM			PC Approved	09/30/2010 12:00:00 AM	ADDRESS	34.0659	-118.29143	Delta 6 modifications to the approved set of plans. Changes to lighting and ckts in room 301.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27386	16041-20001-19559	8252 N MORSE AVE	91605	2	192B161   110	2304002015	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.22134	-118.4162	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (18) modules, and (18) power optimizers. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27387	19041-10000-48909	16650 W SCHOENBORN ST	91343	12	192B137   258	2689010001	M1-1, M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.22245	-118.49545	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS & REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR/OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27388	17041-10000-24958	19150 W MENARD PL	91356	3	165B121   368	2177007013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM			Corrections Issued	07/24/2017 12:00:00 AM	ADDRESS	34.14807	-118.5506	PV1. PC FOR PV SYSTEM USING AC MODULES. TOTAL OF 26 MODULES. TOTAL SYSTEM SIZE IS 8.96KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27389	13041-20000-20219	17309 W RAYEN ST	91325	12	195B133   185	2768018006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.23232	-118.51173	New rooftop PV system for an existing single family residence.  System is Ungrounded and uses Power Optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27390	10041-10000-25849	700 S FLOWER ST # 900	90017	9	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	12/30/2010 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.04835	-118.25882	tenant improvements of existing officesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27391	16041-20000-13980	6944 N BEVIS AVE	91405	6	183B149   460	2219016020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Expired	06/07/2018 12:00:00 AM	ADDRESS	34.19685	-118.45555	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. PV addition system size is 3.6 kWac and consists of (1) inverter, (18) module, and (1) load center. Total system size is 4.5 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27392	15041-20001-11998	20403 W VIA MEDICI	91326	12	219B109   291	2701056010	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM			PC Approved	05/04/2015 12:00:00 AM	ADDRESS	34.29512	-118.57908	Expedited per customer request.PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (28) Kyocera KU 260-6 <odules(1) PVI-6000 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27393	13041-10000-21116	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	33.94955	-118.38214	TENANT IMPROVEMENT. MCC ROOM. ADDING 14 LIGHTS. 1396 SQFT. EMERGENCY LIGHTING. 1 STORY BUILDING. TITLE 24 PLAN CHECK ONLY. EXISTING BUILDING.PERMIT TO BE PULLED AT THE EPC COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27394	12041-10000-09723	5469 W 99TH PL 1-10	90045	11	093B173   662	4128020009	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Apartment			04/27/2012 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	33.94681	-118.37701	PLAN CHECK FOR REPLACING FACP OF AN EXISTING FIRE ALARM SYSTEM. ADD A SMOKE DETECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27395	13041-20000-17567	1875 CENTURY PARK EAST #1460	90067	5	132B161    11	4319002060		West Los Angeles				2679.01	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Expired	07/28/2015 12:00:00 AM	PIN	34.06139196	-118.41527843	TI office space title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27396	15041-20000-09163	15739 W VENTURA BLVD	91436	5	168B141   552	2261009012	C4-1L, R1-1, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.15563	-118.47654	Plan check for Fire alarm panel. Replace existing fire alarm panel with new fire alarm panel and 1 device	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27397	18041-10000-30242	9373 N REMICK AVE	91331	6	198B161   262	2629027024	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.2392	-118.41356	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27398	10041-20000-19691	8383 W 3RD ST	90048	5	138B173   748	5511015015	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.07312	-118.37285	energy plan check retail space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27399	19041-20000-52451	16045 W FOOTHILL BLVD	91342	7	228B141   555	2603009043	[Q]C2-1-CPIO	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/17/2020 12:00:00 AM		Permit Finaled	02/17/2022 12:00:00 AM	ADDRESS	34.32166	-118.48062	$0 Permit fee due to SB1222 and AB1414PV3.  Install 163.53 KW DC/148.31 KW AC CEC roof mounted PV system.  (414) modules with (2) 66.6 KW inverter, (1) 200A panel, (1) 100A panel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27400	16041-10002-39315	6765 W SELMA AVE 1-38	90028	13	148-5A185 276	5547013017	C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM			PC Approved	10/30/2019 12:00:00 AM	ADDRESS	34.09981	-118.33796	Change to an approved set by revising feeders and modifyig some load on EV panel. All changes under delta-5 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27401	19041-10000-25696	1925 S CENTURY PARK EAST 12TH FLR	90067	5	132B161    30	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	INTERIOR REMODEL ON 12TH FLOOR COMMON AREA. T-24 ENERGY ONLY.AREA OF WORK IS  1560 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27402	10041-20000-02889	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	02/18/2010 12:00:00 AM		Permit Finaled	03/08/2010 12:00:00 AM	ADDRESS	34.13855	-118.36112	ENERGY PLAN CHECK 9TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27403	14041-10000-27408	12515 W VOSE ST	91605	2	183B161   345	2324032008	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	34.19856	-118.40601	Installation of roofmounted residential solar PV standard plan. # of inverters: 1. System size: 6kW. # of modules: 27.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27404	15041-20000-33667	6022 N VARIEL AVE	91367	3	177B105    71	2149005020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.18017	-118.59257	"Plan check for power and energy.  Total area = 27,216 sq. ft.TI &CHANGE OF USE FROM WAREHOUSE/OFFICE TO ADULT EDUCATIONAL CLASSES & ASSEMBLY AREA ""TRADE/MUSIC/PROFESSIONAL SCHOOL/MEDICAL CLINIC W/OPERATIONAL ROOMS"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27405	10041-10003-01492	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	01/17/2012 12:00:00 AM	ADDRESS	34.09676	-118.29487	Under this permit , we cover installation of  a 100 H.P fire pump to previously approved. TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27406	13041-10000-32342	18425 W ARMINTA ST	91335	12	189B125   436	2102015***	(Q)RD6-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.21394	-118.53464	PV1, Install 6.615 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE6000A-US. 27 modules Yingli YL245-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27407	16041-10000-31376	8039 N WEBB AVE	91605	6	189B169    98	2310008003	C2-1VL-CUGU, M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.21678	-118.38897	TITLE 24 PLAN CHECK ONLY.  T.I. - CHANGE OF USE FROM (E) RESTAURANT TO RETAIL STORE.   NEW LIGHTING AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27408	15041-10000-37992	1627 S ABBOT KINNEY BLVD	90291	11	108B145  1549	4241036021	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	33.98975	-118.46328	T-24, TI TO A RETAIL BUILDING, SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 945.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27409	11041-10000-04061	6355 N DE SOTO AVE	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Apartment			03/03/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.18639	-118.58869	NEW FIRE ALARM SYSTEM FOR A NEW 4 STORY APARTMENT BUILDING AND A 2 STORY CLUBHOUSE ON TOP OF A 1 LEVEL GARAGE.  REGULAR PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27410	18041-20000-14722	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Closed	09/20/2021 12:00:00 AM	ADDRESS	33.94571	-118.38857	Plan check for temp power for existing High-rise Building 14 stories. Install 2000A at 277/480V temp service with 6 transformers at 75KVA with spider boxes/load.B# 18016-10000-02619	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27411	13041-20000-07181	1124 S ORLANDO AVE	90035	5	132B173   808	5087009015	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.05644	-118.37374	Photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27412	16041-10000-45606	1020 N VERMONT AVE	90029	13	144B197   761	5539003024	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/16/2021 12:00:00 AM	ADDRESS	34.09057	-118.2915	Full plan check for a service upgrade with 1600-Amp 120/208V service. all electrical equipment is new scope includes 8 panels located in a theater. Total area is 10,590 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27413	13041-10001-27886	4200 W 59TH ST	90043	8	105B181   246	4019009016	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	33.98698	-118.34763	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 3.5 kW.  TRANFORMERLESS. UNGROUNDED. POWER OPTIMIZER.(14) TRINA SOLAR # TSM-250PA05.18(14) POWER OPTIMIZER(1) SOLAREDGE # SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27414	17041-30000-46215	9522 N SEPULVEDA BLVD	91343	7	201B145   630	2656010037	(Q)P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.24345	-118.46723	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,123 sq. ft.Note: Building application has been generated under 17016-20000-35139	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27415	18041-10000-47299	11085 W OLINDA ST	91352	6	192B173   267	2632027025	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.22	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	01/10/2021 12:00:00 AM	ADDRESS	34.22307	-118.37277	NOTE: Permit fees are $0 due to AB 1414PC FOR PV SOLAR SYSTEM. SYSTEM SIZE IS 378.51 KWDC - 318KWAC. 1023 PV MODULES (BOVIET SOLAR -BVM6612M-370). 9 CENTRAL INVERTERS (SOLECTRIA SOLAR - PVI 50TL &PVI28TL). 1 LOAD CENTAR + 1 NEW 800A , 3PH, 277/480V SWITCHBOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27416	13041-10002-03981	2626 E 25TH ST	90058	14	117A219   147	5168023009	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.0152	-118.22477	((((3/27/2014- CHANGES MADE TO APPROVED SET OF PLANS. RELOCATED ONE MOTOR AND REVISED SOME BREAKER SIZES AND FEEDERS FOR MOTORS. ALL CHANGES HAVE BEEN CLOUDED. PERMIT NOT REQUIRED, PERMIT FEES COVERED ON THE ORIGINAL SET)))REPLACEMENT OF 480V DISTRIBUTION SYSTEM. RATED AT 4000A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27417	16041-10000-41777	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.04443	-118.29612	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 92300 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27418	13041-20000-09482	1999 S AVENUE OF THE STARS flr 21	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM			PC Approved	04/12/2013 12:00:00 AM	ADDRESS	34.05886	-118.41642	13041-20000-09482 Plan check for energy and emergency lighting. Commercial high-rise. 21st floor. Alliance Bernstein.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27419	17041-10000-19822	17541 W LANARK ST	91325	12	189B129    82	2201006009	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.21808	-118.51567	plan check for battery back-up system with back-up panel on single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27420	14041-10000-26096	1408 S ARDMORE AVE	90006	1	129B193  1466	5075011001	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.04597	-118.30239	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 795 SQFT.  2008 T24 COMPLIANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27421	18041-10000-09804	4469 W SUNSET DR	90027	4	147B197   674	5542006002	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Issued	03/22/2018 12:00:00 AM	ADDRESS	34.0983	-118.28683	PC FOR TENANT IMPROVEMENT TO EXISTING TAKE-OUT RESTAURANT (SUPERCOOL CREAMERY) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 395 SQ.FT.B#17016-10000-30343	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27422	12041-10000-00821	401 S ROSSMORE AVE	90020	4	135B185   243	5505011012	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.0668	-118.32745	New 12.9kw rooftop photovoltaic system for an existing single family residence.  3 inverters and 60 modules.  Conductor to be run underground in a Methane Zone.  (No methane report was provided so project shall follow Methane Standard Part V, Sec. D.2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27423	11041-20000-26569	3601 S TROUSDALE PKWY	90089	9	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM	ADDRESS	34.02017	-118.28558	energy plan check hallway on 2nd floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27424	15041-20001-23492	6817 W FRANKLIN AVE	90068	4	150A185   287	5549018024	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM			PC Info Complete	06/01/2016 12:00:00 AM	PIN	34.10444099	-118.33917245	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE ADDING NEW LOAD AND PANELS.  CHANGES NOTED DELTA B AND CSERVICE UPGRADE TO 1200 AMPS.  RECONNECT EXISTING LOADS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27425	19041-20000-43999	2107 N WEST SILVER LAKE DR	90039	4	147A207    34	5439031025	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.09738	-118.26668	PV1. INSTALL 6.67 KW AC PV SYSTEM WITH (23) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27426	14041-10000-06891	9513 N JELLICO AVE	91325	12	201B129   429	2755005004	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.24382	-118.51897	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.PV1 17.28KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE5000A-US, 2x SOLAREDGE SE6000A-US}]. [(64)modules: {solarworld SunModule SW-270 mono}] with optimizers: [SOLAREDGE {POWERBOX OP300}]   Changes on plans include fault current. Over 50% design change - system changed from original : see 13041-10000-30903	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27427	15041-10000-28980	1139 E 12TH ST	90021	14	123A213   178	5132015040	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			Reviewed by Supervisor	10/06/2015 12:00:00 AM	ADDRESS	34.03078	-118.24639	Addition and remodel of (E) commercial building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27428	13041-10000-22200	1816 N SAN JACINTO ST	90026	13	145-5A205 279	5431032020	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM			PC Info Complete	08/15/2013 12:00:00 AM	ADDRESS	34.09239	-118.2695	PV1 2.1KWAC 240V MICROINV 2STORY. STD. ROOFMOUNT.[( 10) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: SOLARTECH ENERGY CORP.SEC-6P-60-240]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27429	11041-10000-03286	1555 N VINE ST #107	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/18/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	34.09923	-118.32707	T24 lighting plancheck for remodeled restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27430	18041-10000-03382	4528 W BRAZIL ST S	90039	13	165B205    89	5593011004	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.14674	-118.27336	REPLACE MH LUMINAIRES OUTDOOR WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27431	15041-10000-16671	5927 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	33.93319	-118.38745	TI-24 FOR OUTDOOR LIGHTING (E) FEDEX BUILDING. . ADDING 5 LIGHITNG POLES. TOTAL SQ. FT. 40064. COUNTER PC OK BY NABIL M.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27432	13041-20000-07017	2600 N SUMMITRIDGE DR	90210	5	156B157   371	4386013005	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.12137	-118.42066	Plan check for addition to a 10000sqft house and a new 800A service. PC fee per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27433	17041-10000-19752	3202 W ADAMS BLVD	90018	10	123B189   714	5052015032	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.03243	-118.31914	REPLACE  LIGHTING FIXTURES TO LED TYPE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27434	17041-10000-16607	21800 W OXNARD ST SUITE 1192	91367	3	177B105    81	2146006046	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.17898	-118.60253	PC FOR OFFICE TI TITLE-24 ENERGY ONLY in a high rise. TOTAL AFFECTED AREA 1129 SQ.FT. INSTALLING LIGHTS AND RECEPTACLES.BL# 17016-10000-11502	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27435	11041-20000-25696	1640 S SEPULVEDA BLVD Ste 460	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM			PC Approved	12/02/2011 12:00:00 AM	PIN	33.81653075	-118.3084035	"T.I.  Existing office space.  Remodel of the light fixtures for Ste # 460.  Plan check is for energy only.""COMPLY WITH DEPARTMENT ORDER effective date10/11/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27436	15041-10000-27843	380 WORLD WAY LV 3 T10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Info Complete	08/25/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS FOR STORAGE SPACE.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 324.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27437	14041-20000-18013	9301 N TAMPA AVE 5517	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Tittle 24 plan check only for a commercial building with 252 SQ feet, Kiosk haircut, base on building permit submital #: 14016-20000-12338.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27438	12041-10000-00286	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM	04/18/2012 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.27548	-118.56626	New 454.02KW roof mounted Photovoltaic system for Walmart.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27439	14041-20002-02606	7944 N ANDASOL AVE	91325	12	189B133   404	2201022018	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.21542	-118.5116	Changes from previously approved plans.  Change include removed the AC disconnect switch.Note: Permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN USING POWER OPTIMIZERS*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27440	13041-20000-36201	1790 N ALTA MURA ROAD	90272	11	135B133   207	4425002001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Expired	09/14/2023 12:00:00 AM	ADDRESS	34.06316	-118.5039	Remodel interior, pc for power only. new work greater than 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27441	12041-10000-27830	4219 W AVENUE 40	90065	14	157-5A217  32	5684014050	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.12779	-118.23136	PV1 ROOF MOUNTED SOLAR INSTALLATION 2.45 K. ENPHASE 215 MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27442	19041-10000-33221	8212 N VAN NUYS BLVD	91402	6	192B149   493	2212004037	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.22017	-118.44858	CHANGE OF USE FROM  RETAIL TO MEDICAL (PHYSICAL THERAPY) OFFICE. INSTALLING NEW CIRCUITS & LIGHTS. EXISTING PANELS TO REMAIN. TOTAL AREA: 1964 SQR FT.BUILDING PERMIT: 19016-20000-19970	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27443	19041-10000-15943	3015 S OCEAN FRONT WALK	90291	11	103-5A145  23	4226023005	C1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Issued	05/14/2019 12:00:00 AM	ADDRESS	33.9793	-118.46698	PC for eneregy (resturant) TI. area of scope 1,525SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27444	15041-10000-07180	1601 N SAN ONOFRE DR	90272	11	135B133   225	4425003029	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	34.06191	-118.50471	PC FOR POWER. NEW SINGLE FAMILY HOME. PER APPLCATION CALCULATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27445	13041-10000-07641	9620 S AIRPORT BLVD 1ST FLOOR	90045	11	093B169   171	4125023034	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	ADDRESS	33.94842	-118.38574	TI FOR A HOTEL LOBBY GIFT SHOP.  NEWLY CONNECTED LOAD < 400A.  419 SQ FT, T24 PLAN CHECK ONLY.PERMIT TO BE ISSUED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27446	13041-10000-26474	2029 S CENTURY PARK EAST 28TH FLR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	TITLE-24 ONLY PLAN CHECK; TI FOR CONFERENCE ROOM, ROOM UPGRADE FOR BANK OF AMERICA. ADDING (2) EMERGENCY FIXTURES ON EXISTING CKT FED EXISTING VIA GENERATOR. TOTAL AREA IS 821 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27447	12041-20000-27823	7270 W MELROSE AVE	90036	5	141B181   622	5525013004	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			Corrections Issued	11/19/2012 12:00:00 AM	PIN	34.0832604	-118.34817541	Plan check for energy and emergency lighting. 1200 or so conditioned sqft (about 206 is outdoor). Restaurant. Low-rise commercial building. CHANGE USE FROM RETAIL TO RESTUARANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27448	18041-10000-08414	1130 S FIGUEROA ST Retail Pod-ium	90015	14	127-5A207 344	5138015045	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Expired	02/02/2024 12:00:00 AM	ADDRESS	34.04261	-118.26574	PC for new FA system for Retail Podium of Oceanwide Plaza. This fire alarm system is networking with fire warning systems of Tower 1, Tower 2, and Tower 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27449	14041-10000-23594	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	33.79072	-118.29449	PLANCHECK PER APPLICANTS REQUEST FOR THE ADDITION OF 1  SERCURITY ACP CKT ON PANEL 2A3 FOR KAISER PERMANENTE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27450	16041-10000-01324	3912 S DALTON AVE	90062	8	117B193  1324	5036019004	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.01496	-118.30331	PV1, ROOF MOUNTED SOLAR SYSTEM. (14) MODULES AND (1) 3.6 KW INVERTER. TOTAL SIZE:3.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27451	17041-10000-39072	5441 N TOPANGA CANYON BLVD	91367	3	174B101   445	2169025097	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.16977	-118.60612	Plan check for office and retail TI for Tiltle 24 energy only.  Scope includes new light, recepticals and circuits. Total effected area 3744 sq-ftB# 17016-20000-24359	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27452	14041-10000-12871	540 N BRITTANIA ST	90033	14	130-5A223 400	5175030018	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.05035	-118.21245	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27453	16041-20000-17862	15250 W VENTURA BLVD SUITE 410,-403,402	91403	5	168B145  1166	2276007059	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.15351	-118.46549	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AD EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 3460.  SCOPE OF WORK IN SUITE 410, 403, 402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27454	19041-30000-20470	3672 S JASMINE AVE	90034	5	120B165   936	4313003029	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			05/30/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	05/22/2022 12:00:00 AM	ADDRESS	34.02438	-118.40378	1200A 208Y/120V 3ph-4w service for new 5-story, 17-unit apartment building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27455	14041-10001-05380	1999 W ADAMS BLVD	90018	8	123B193   477	5058015005	[T][Q]C2-2D	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM			PC Approved	07/30/2014 12:00:00 AM	ADDRESS	34.03285	-118.30872	REVISIONS TO PERMITTED SET OF PLANS- SEE SINGLE LINE DIAGRAM; CHANGES TO LIGHTING SYSTEMPLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. ELECTRICAL UPGRADES TO THE GOLDEN STATE MUTUAL LIFE INSURANCE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27456	17041-20000-26151	18574 W MARILLA ST	91324	12	201B121   437	2763033041	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	PIN	34.24674914	-118.53870804	Plan check for solar pv system, roof-mounted on SFD.7.2kW ungrounded system. (30) EnPhase M250 microinverters.(30) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27457	10041-20000-06071	9255 N SUNLAND BLVD	91352	2	198B173    88	2408002023	M1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.00	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Expired	11/01/2012 12:00:00 AM	ADDRESS	34.23755	-118.36793	New electrical installation for a new carwash. New 3ph 4w 208/120 800A service. EPC: Power and Energy(T-24).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27458	17041-20000-23580	12021 N LONGACRE AVE	91344	12	216B125   409	2601031040	(T)(Q)RE40-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Issued	08/10/2017 12:00:00 AM	ADDRESS	34.2894	-118.53041	pv1install ground mounted pv system sized 15.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27459	15041-20001-05987	4600 N COLDWATER CANYON AVE	91604	2	168B161   906	2362019013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			10/30/2017 12:00:00 AM			PC Approved	10/30/2017 12:00:00 AM	ADDRESS	34.15402	-118.4136	10/30/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to feeder sizing and the electric car chargers have been relocated.*****Previous Work Description*****Plan check for power and Title 24 (energy).  Total area = 21,011 sq. ft. (indoor) + 4,049 sq. ft. (outdoor)New 4 story 32 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27460	10041-20000-10632	11811 W OLYMPIC BLVD	90025	11	123B149   409	4259023015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	PIN	34.03353292	-118.45117088	INTERIOR TENANT IMPROVEMENT TO CREATE THREE NEW CLASSROOMS AND TWO NEW FACULTY OFFICES.  Plan check was requested by the applicant for power only.  Load was reduced from the existing panels.  Title 24 energy was check in app# 10041-20000-07483.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27461	19041-10001-38456	1515 W 240TH ST	90710	15	042B193   718	7439008032	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Approved	11/08/2019 12:00:00 AM	ADDRESS	33.8074	-118.30413	T-24, plan check for energy  only. scope of work includes new lighting and receptacles. Total sq. ft. 2579.Permit fees paid under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27462	13041-20001-23541	19030 W TRIBUNE ST	91326	12	207B121   166	2718014006	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.26654	-118.54742	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.6 KW AC. USING 40 MODULES AND ENPHASE MICROINVERTER. NONSTANDARD PLAN. 4 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27463	16041-20001-39218	16357 W PLUMMER ST	91343	12	198B137    32	2677020013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.24309	-118.48919	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with 200A MSP, derating main to 175A. Existing 6kW ungrounded system on roof. New system is 4.2kW ungrounded w/(16) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27464	18041-20000-38825	20105 W RINALDI ST #100-110	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.27543	-118.57209	Plan check for First Time Tenant nail salon  Total area: 2564 sq ft B#18016-20000-32903	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27465	19041-10000-31149	2193 E 14TH ST	90021	14	120A217    59	5167009006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	01/31/2024 12:00:00 AM	ADDRESS	34.02364	-118.23344	TI IN AN EXISTING COMMERCIAL 2 STORY BULDING. INSTALLING NEW LIGHTS. T-24 ENEGRY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27466	14041-20000-20735	11201 N CHALON ROAD	90049	5	141B145   149	4369009007	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Expired	09/06/2023 12:00:00 AM	ADDRESS	34.08239	-118.46048	Plan check for power only. New 51,371 sqft mansion (SFD).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27467	18041-10000-42452	8235 W LINCOLN TER	90069	4	147B173   294	5555024017	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM			Reviewed by Supervisor	11/13/2018 12:00:00 AM	ADDRESS	34.09777	-118.37009	PLAN CHECK FOR (3) 5 KW AC BATTERYS, (1) NEW PANEL, (1) NEW LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27468	10041-10000-02646	901 E NEW DOCK ST	90731	15	024B209     5	7440020***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2947.00, 2961.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	06/14/2010 12:00:00 AM		Permit Finaled	11/09/2011 12:00:00 AM	ADDRESS	33.7552	-118.25713	Plan check power for new installation of 600 amps sevice for Regenrative Thermal Oxidizer (RTO). Permit is for feeders to CP101, CP102, and P101 disconnect.  Site is methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27469	17041-10001-13432	5353 W PICO BLVD	90019	10	129B177   948	5085033017	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			Ready to Issue	07/19/2017 12:00:00 AM	ADDRESS	34.04858	-118.35493	PC FOR CHANGES TO APPROVED SET UNDER DELTA 1. PERMIT WAS PULLED UNDER MASTER. SCOPE INCLUDES 8 NEW DEVICES AND REPOSITIONING OF APPROVED DEVICE. **************************************************************************NEW FA SYSTEM FOR SCHOOL. PC FOR FIRE ALARM ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27470	19041-10000-07859	20929 W VENTURA BLVD UNIT 16	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTING AND EXIT SIGN TO EXISITNG RETAIL SPACE FOR FUTURE TENANTPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27471	18041-10000-28249	7920 N DEERING AVE	91304	3	189B105   273	2109017026	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.21443	-118.59488	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27472	15041-10001-09380	200 S LA BREA AVE	90036	5	138B181  1265	5513023004	C2-1LD, [Q]C2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.07067	-118.34383	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 6 ON FLOOR PLANS.  CHANGES INCLUDE LIGHTING FIXTURE REMOVAL AND REVISIONS TO ENERGY CALCS.(((Interior tenant improvement at existing retail store( PETCO)PLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27473	11041-20000-23027	4319 W JEFFERSON BLVD	90016	10	120B181   701	5057020014	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM			Corrections Issued	10/27/2011 12:00:00 AM	ADDRESS	34.02578	-118.3436	EXISTING WAREHOUSE.  ADDING NEW LIGHT FIXTURES.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27474	14041-20001-00633	12943 W AZTEC ST	91342	7	228B161   260	2511035019	RS-1	North Valley		Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.32276	-118.41532	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING ENPHASE MICROINVERTER M215. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27475	19041-10000-08217	12240 W ARCHWOOD ST	91606	2	180B165   226	2322001902	OS-1XL	South Valley	North Hollywood - Valley Village	NoHo		1233.01	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.19202	-118.40085	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27476	19041-20000-23942	3737 S WATT WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	08/21/2020 12:00:00 AM	ADDRESS	34.01921	-118.28872	Plan check for power only. replace 800A panel board and new ATS Emergency panel. Existing panel boards to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27477	09041-10001-14607	2190 E 14TH ST	90021	14	120A217    90	5167016024	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.02344	-118.23347	New 3 story 30 unit office building. Plan Check is for new sevice, panels, circuits, AC units. & energy.Building Permit # 07016-10000-17539.  NOTE: SPACES ARE NOT TO BE USED FOR RESIDENTIAL PURPOSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27478	16041-20000-05058	6201 N COLDWATER CANYON AVE	91606	2	177B161   414	2331011111	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.18306	-118.41396	"""0$ permit fees due to senate bill 1222""PLAN CHECK SUBMITTAL - ROOF MOUNTED SOLAR PV SYSTEM FOR AN EXISTING APARTMENT SYSTEM SIZE 40 KW AND 160 PV MODULES (CS6P255P) AND 5 INVERTERS (SB70000US-12)"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27479	16041-20002-20270	18981 W VENTURA BLVD	91356	3	174B121   401	2163020020	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.17265	-118.5472	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES TO REFLECT FIELD CONDITIONS.  THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27480	17041-10000-42669	843 S SPRING ST	90014	14	127-5A209 226	5144016052	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.04215	-118.25476	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27481	18041-20000-36318	20035-20043 W VANOWEN ST	91306	3	183B113   873	2135030003	P-1VL-RIO, [Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM			PC Info Complete	09/24/2018 12:00:00 AM	ADDRESS	34.19394	-118.57011	ti to an existing commercial building consolidating existing 5 meters into a new 600 AMP service.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27482	12041-20000-02192	1525 E SAN VICENTE BLVD	90272	11	126B133   140	4407015004	R1-1	West Los Angeles				2628.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2012 12:00:00 AM			Reviewed by Supervisor	02/08/2012 12:00:00 AM	ADDRESS	34.04184	-118.50346	NEW SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27483	18041-20000-38036	945 N OXFORD AVE	90029	13	144B193  1239	5535021002	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Apartment			10/04/2018 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	07/12/2021 12:00:00 AM	ADDRESS	34.08755	-118.30803	Plan check for power and energy. Project site is a new 3-story, 11-unit apartment building. 800A 240/120V 1ph-3w service.  Note: Building permit has been issued under 17010-10000-02568	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27484	15041-10000-26341	11060 W RANDALL ST	91352	6	198B173   103	2408003041	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.23647	-118.37205	PLAN CHECK FOR ENERGY ONLY. REPLACING EXISTING LIGHTS ON EXISTING CIRCUITS WITH LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27485	18041-10001-46095	511 N POINSETTIA PL	90036	5	141B181  1122	5526022014	R1V2	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.08062	-118.34877	SUPPLEMENTAL EXPEDITED PER CUSTOMER REQUEST.PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 37 MODULES (SOLARIA POWER XT 360R-PD), 37 MICROINVERTERS (ENPHASE IQ7-PLUS-72-2-US). SYSTEM SIZE IS 13.32 KWdc. SCOPE INCLUDES 80amp  AC COMBINER BOX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27486	19041-10000-15431	688 N NEW HIGH ST	90012	1	133-5A215 166	5408014018	C2-2	Central	Central City North	Historic Cultural North		2071.02	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.05981	-118.23861	Replace fluorescent troffers with new LED retrofit kits 2nd floor, indoor only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27487	17041-20000-03174	9700 N DONNA AVE	91324	12	201B121   411	2762032030	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.24716	-118.54739	PV1.  Install 14.25 kW roof mounted grid tied PV system.  (50) modules with microinverters.$0 permit fee per State Senate Bill SB1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27488	10041-10000-18830	2050 W JOHN S GIBSON BLVD CRANE #3	90731	15	024B201     7	7440016912	[Q]M3-1	Harbor	Port of Los Angeles	Northwest San Pedro, Wilmington	YES	2951.01	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Closed	11/05/2012 12:00:00 AM	ADDRESS	33.75959	-118.28627	INSTALL A NEW CRANE AT BIRTH #102 IN TERMINAL WBCT.  (CRANE #3 of 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27489	17041-10000-29905	11327 N BERTRAND AVE	91344	12	213B125   614	2715019027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South	YES	1112.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM			Verifications in Progress	10/06/2017 12:00:00 AM	ADDRESS	34.27666	-118.52531	PC FOR ROOF TILED PV SYSTEM. USING 692 MODULESS (TILES) AND 2 INVERTERS SYSTEM SIZE 15.2KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27490	17041-10000-31926	11845 W OLYMPIC BLVD # 100	90064	11	123B149   463	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Info Complete	10/05/2017 12:00:00 AM	ADDRESS	34.03291	-118.45177	PC for T24 only for health club TI. Rewiring to existing fixtures and adding new LED light fixtures. Total affected area is 4455 sqft. B: 17016-30000-05487	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27491	19041-20000-15606	2935 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.10427	-118.24362	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27492	19041-10000-47671	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	05/12/2022 12:00:00 AM	ADDRESS	33.9427	-118.40223	PLAN CHECK FOR TITLE 24 (ENERGY ONLY). TOTAL SQUARE FOOTAGE: 9568 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27493	18041-20000-28721	16253 W LOVETT PL	91436	5	165B137    71	2284015007	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Re-Activate Permit	04/17/2019 12:00:00 AM	ADDRESS	34.15165	-118.48809	Plan check for a PV1 roof-mounted PV system. System size is 21.35 kWdc/18 kWac and consists of (3) inverters, (70) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27494	19041-20000-25211	11914 N DARBY AVE	91326	12	216B121   231	2870007035	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.28941	-118.53981	PV1. 12.285 KW DC / 11.054 KW AC roofmountd system with (39) modules and micro inverter (IQ7 plus-72-x-US) interconnecting through a new load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27495	17041-20000-24347	7061 W FOOTHILL BLVD	91042	7	202-5A201 456	2568016050	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.24814	-118.28543	permit fee $0.00 by state senate bill no. 1222PV2.  Install 50.3 kW roof mounted grid tied PV system.  Feed-in-tariff project.  (168) modules with (2) SolarEdge inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27496	16041-10000-19137	978 S MARIPOSA AVE 1-7	90006	10	129B197   103	5078003016	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.10	Electrical	Electrical	Apartment			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.05337	-118.29881	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 7-UNIT,  3 STORY APARTMENT BUILDING. SCOPE INCLUDES 28 FA DEVICES, 1 FA PANEL, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27497	19041-20000-40228	3761 S WADE ST	90066	11	111B153   360	4246032036	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.00253	-118.43895	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTNG SFD. SYSTEM SIZE IS 5.36KW DC/2.61KW AC. SCOPE OF WORK CONSISTS OF (16) PV MODULES WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27498	19041-10000-20058	14401 W HAMLIN ST	91401	6	180B149   588	2237014014	[Q]C1-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.18885	-118.44671	Replace fluorescent troffers with new LED retrofit kits -  Indoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27499	19041-10000-01803	953 N SYCAMORE AVE	90038	4	144B181   641	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	TI IN THE EXISTING COMMON AREAS ( LOBBY, RESTROOMS & CORRIDORS) OF THE 1ST, 6TH & 7TH FLOORS (SHOWN AS DELTA 15) . T-24 ENERGY ONLY. Total Square Feet: 5,410.Building Permit: 18016-10000-30287	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27500	18041-10000-09662	19500 W PLUMMER ST B1	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			PC Info Complete	03/16/2018 12:00:00 AM	ADDRESS	34.2426	-118.55846	PC for T24 only for remodeling of existing restuarant dinning area. Installing new lights, receptacles and equipment.B# 18016-10000-06476. Total area 1095sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27501	19041-10001-21968	414 N EAST RUSTIC ROAD	90402	11	123B129   586	4410017010	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.03239	-118.51749	Change to an approved set by upgrading the PV1 system with (22) modules and 6KW AC. New system is 6kW AC / 6.27 KW DC.(((NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 MODULES (Q-CELL 285) , 20 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 5.7KWdc and 5KWac)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27502	18041-20001-44153	2492 N CHEREMOYA AVE	90068	4	154-5A189 484	5580005016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Apartment			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.11576	-118.3209	01/11/2019 Changes to an approved set of plans. Single line diagram has been updated to show PV interconnection configuration on the field.*****Original Work Description*****PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 8 MODULES (SW 325 XL MONO) AND 8  MICROINVERTERS..  SYSTEM SIZE IS 2.6KWdc and 2.24KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27503	10041-20000-23688	7623 W FOOTHILL BLVD	91042	2	204A197    87	2558033028	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	12/27/2010 12:00:00 AM	ADDRESS	34.25527	-118.29845	PLAN CHECK FOR T24 ENERGY OUTDOOR LIGHTING. PERMIT FOR ADDITIONAL CKTS AND LOW VOLTAGE WIRING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27504	13041-20000-21025	12414 W DEERBROOK LANE	90049	11	138B141   381	4494009001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.07309	-118.48436	PV1 TRANSFORMERLESS SYSTEM. 4 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 7.848KW. 24 MODULES AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27505	13041-10001-34397	1028 S CURSON AVE	90019	4	132B177   859	5085003006	R2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.05666	-118.35734	Expedited RSES plan check per applicant request.{{{PV1, install 3 kw DC roof-mounted solar array for a 1-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. (12) modules: Trina Solar TSM-250PA05.18.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27506	16041-10000-21429	1141 W 2ND ST	90012	1	133-5A209 224	5152009901	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	08/08/2017 12:00:00 AM		Issued	08/08/2017 12:00:00 AM	ADDRESS	34.0588	-118.25625	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012ADDITION TO EXISTING PV SYSTEM. 150KW ROOF MOUNTED. INCLUDES 632 MODULES EACH. INCLUDES (5) 27.5KW INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27507	19041-10000-41909	2801 N SAN FERNANDO ROAD	90065	1	150B213   101	5457006035	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/01/2021 12:00:00 AM	PIN	34.1110837	-118.24300111	PC FOR ENERGY ONLY, SCOPE OF WORK IS ADDING LIGHTS TO AN ADA BATHROOM. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 275 SFQT. B#18016-20000-40910	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27508	16041-20000-44088	1846 N CHEROKEE AVE	90028	13	150A185   294	5547004020	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			12/15/2016 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	09/13/2023 12:00:00 AM	ADDRESS	34.10445	-118.33463	New apartment building with 1200A 208Y/120V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27509	14041-20002-02476	6080 W CENTER DR 3RD FLOOR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	33.97713	-118.39172	Plan check only for modification to modification of an approved set. Change scope of lighting work, different fixtures. Recheck for Title-24 requirements.[Modifications to approved set.  Change of layout and scope of work to include additonal areas/remove others.]  (((T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE 3RD FLOOR)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27510	19041-10000-19998	5901 W CENTURY BLVD 1500	90045	11	090B169    15	4124030042	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE SPACE IN A HIGHRISE. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA 2737 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27511	19041-20000-52368	2729 W WAWONA PL	90065	14	160-5A219 144	5683036008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Issued	12/18/2019 12:00:00 AM	PIN	34.13455197	-118.2241612	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 7.56 KW DC/6.84 KW AC CEC. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH A 7.6 KW INVERTER AND A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27512	17041-20006-16993	9408-9410 N OWENSMOUTH AVE	91311	12	198B105    66	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	PIN	34.2410613	-118.60115579	04-24-2018 Changes to an approved set of plans. Changes include install receptacles. Changes has been clouded as delta 5. Permit shall be under original application 17041-10000-16993	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27513	13041-20000-31535	9074 N VAN NUYS BLVD	91402	6	198B149   582	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.23513	-118.45006	T24 for existing non highrise office building. scope of work 1980 sqrft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27514	14041-10000-07521	21650 W OXNARD ST suite 550	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.17901	-118.60107	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. HIGH RISE. OFFICES. NO CHANGE IN OCCUPANCY. SUITE 550. 4515 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27515	16041-10000-33580	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.03982	-118.24098	PV2. NEW SOLAR SYSTEM ON EXISTING APARTMENT BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 10.00 KWac.(1)INVERTERS-SOLAREDGE 10000A-US(36)SOLAREDGE OPTIMIZERS-P400(36)MODULES-CANADIAN SOLAR CS6X320P	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27516	16041-20002-08280	10065 N GLENOAKS BLVD	91352	6	204B169   115	2537019900	OS-1XL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			07/11/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	PIN	34.25227958	-118.39227029	"07/11/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes include the relocation of the LADWP service panel.  PERMITTED 16041-20000-08280. CHANGE OF ADDRESS FROM 10101 N GLENOAKS BL.*****Previous Work Description*****SUPPLEMENTAL PERMIT FOR PERMIT #16041-10000-08280 TO CORRECT ADDRESS FROM ""10100 N GLENOAKS BLVD"" TO ""10101 GLENOAKS BLVD."" PER INSPECTORS REQUEST.*****Previous Work Description*****PC FOR POWER. INSTALL ELECTRIC SERVICE FOR NEW MOTOR OPERATED VALVE AND ASSOCIATEDCONTROL EQUIPMENT. HAZARDOUS AREA"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27517	14041-10000-17653	11300 W OLYMPIC BLVD	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.03792	-118.44134	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICEES. SUITE 920.  1800 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27518	17041-10000-36204	10250 W SANTA MONICA BLVD STE. 1440	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for first time tenant ""Next Health"" Ste. 1440 at Westfield Century City.  Install new electrical equipments,  total affected area: 1,882 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27519	17041-10000-12235	11766 W WILSHIRE BLVD 17TH FL	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.04804	-118.46227	17TH FLOOR TI, COMMON AREA UPGRADES. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27520	16041-10000-06768	333 E 1ST ST	90012	14	130-5A215 321	5161012012	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.04991	-118.23994	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM EXISTING RETAIL TO RESTAURANT; AND COMBINE WITH (E) ADJACENT RESTAURANT BY REMOVING EXISTING NON-BEARING PARTITIONS. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND ONE 125A PANEL. TOTAL AFFECTED AREA IS 3881 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27521	12041-10000-03409	10250 W SANTA MONICA BLVD # 698	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IMPROVEMENT TO (E) RETAIL SPACE - REMOVE NON BEARING PARTITION WALLS; NEW DISPLAY FIXTURES; PATCH & RELOCAT CEILING LIGHTSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27522	18041-10000-33292	725 S FIGUEROA ST 26TH Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for T24 only, TI at level 26 with new offices, conference rooms, and a pantry, floor area under this TI is 6,971sf .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27523	14041-20000-31649	10648 N MELVIN AVE	91326	12	207B117   275	2708005009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.26383	-118.55992	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECT WITH MSP.(44) LG MONOX MODULES, (44) ENPHASE M250 MICROINVERTERS.Note: Permit is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27524	13041-10000-35540	13631 W TERRA BELLA ST	91331	6	201B157   163	2645007006	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	02/04/2014 12:00:00 AM	ADDRESS	34.2499	-118.43016	PV1, Install 3.18 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (12) modules: Suniva OPT265-60-4-1B0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27525	16041-10000-19558	22258 W JAMES ALAN CIR 1-8	91311	12	207B101   244	2723013***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Apartment			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.25979	-118.61169	PV1 6.54kw STANDARD ROOF-MOUNTED SYSTEM WITH (20) AC modules interconnecting through the load center and main service panel. Sun Power solar monitor is being installed on the load center. Note: Standard Plan, plan check.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27526	14041-10000-27662	4045 N CARTWRIGHT AVE	91604	2	162B177   202	2423033007	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.14266	-118.36397	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL STANDARD PLAN. SYSTEM SIZE: 3.8 KW.(15) TRINA SOLAR TSM 255(1) SOLAR EDGE SE3800	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27527	16041-10000-35554	7203 N VAN NUYS BLVD	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.20159	-118.44895	T-24, PC for energy only. Change of use from existing payroll check cashing office to new restaurant and tenant approvement of the proposed restaurant. Total affected area is 2054 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27528	17041-10000-23265	11461 W HART ST	91605	2	183B169   229	2320001012	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Issued	07/11/2017 12:00:00 AM	ADDRESS	34.19771	-118.38113	Title 24 plan check.  Replace HID fixtures with new LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27529	18041-10000-42411	8347 S LINCOLN BLVD	90045	11	096B157   339	4114033006	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.96151	-118.42094	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27530	14041-10001-11011	10455 N SUNLAND BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM			PC Approved	06/29/2015 12:00:00 AM	ADDRESS	34.25996	-118.3265	Plan check only. changes under delta pc1. plan check for power and energy. General sales lights (existing to remain) offices (to existing to remain), emergency lighting (existing to remain), and display track lighting added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27531	11041-20000-15032	724 N GRAMERCY PL	90038	13	141B193   480	5535015010	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.08427	-118.31231	Plan check power and energy for new 600A service electrical system for existing 20 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27532	13041-20004-35744	8700 W BEVERLY BLVD 1F	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.07666	-118.3805	05-10-16 CHANGE TO APPROED SET OF PLANS. CHANGES INCLUDE DELTA 8 ONLY, IN CONFERENCE ROOM AND LOUDGE ROOM LIGHTING AND RECEPTACLES LOCATION. ******Previous work description*************************************{{{{{{ 05-21-15 CHANGES TO APPROVED SET OF PLAN. DELTA 3 CHANGES ONLY. UPDATE LIGHT FIXTURES SCHEDULE AND UPDATED LIGHTING AND POWER PLAN, UPDATE TITLE 24 CALCULATION AND PANEL SCHEDULE}}}}}}}[[[[9/10/14  CHANGES TO APPROVED SET OF PLANS. DELTA 2 CHANGES ONLY. CREATION OF AN OFFICE ON THE GROUND FLOOR. ADDITION OF FEW RECPETACLES AND LIGHTING.]]]]]TI 1ST FLOOR. PC for POWER ENERGY GAMMA KNIFE TO MRI. adding 2 UPS as well. Plan checker to verify fees ***ARCHITECTURAL & STRUCTURAL ALTERATION AT THE FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27533	17041-20000-16298	13850 N GARRICK AVE	91342	7	228B157   230	2503016028	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM			Reviewed by Supervisor	06/01/2017 12:00:00 AM	ADDRESS	34.32383	-118.42564	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (18) micro-inverters, (18) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27534	19041-10000-14781	330 S BROADWAY	90013	14	130-5A211 147	5149019020	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/08/2021 12:00:00 AM		Permit Finaled	05/14/2022 12:00:00 AM	ADDRESS	34.05011	-118.24856	TI IN AN EXISTING RESTAURANT / BAR. INSTALING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 19016-10000-06991	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27535	11041-10003-25912	3023 S WESTERN AVE 1-60	90018	10	120B193   522	5053006903	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Apartment			09/17/2012 12:00:00 AM			PC Approved	09/17/2012 12:00:00 AM	ADDRESS	34.02667	-118.30906	Changes to approved plans. Add a branch circuits for sump pump. Delta 8 Revision	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27536	15041-10000-07995	10960 W WILSHIRE BLVD 20TH FL	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	ALTERATIONS IN OFFICE SPACESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27537	13041-20000-21354	9301 N CORBIN AVE UNIT 150	91324	12	198B117   116	2761040014	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.24034	-118.56251	RENOVATION OF EXISTING OFFICES. NEW PARTITIONS. RELOCATION OF SOME FIXTURES. TOTAL AREA 870 SQ FT. RELOCATION OF EMERGENCY FIXTURES. PERMIT ISSUED UNDER THIS APPLICATION. WORK DONE IN UNIT 150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27538	18041-10000-11291	4201-4213 S VERMONT AVE	90037	9	114B197   797	5020027001	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	34.00713	-118.29174	FULL PC FOR POWER AND ENERGY. CHANGE OF USE TO ALL RETAIL ON GROUND FLOOR OF AN EXISTING BUILDING. SCOPE INCLUDES ADDING A NEW 800A 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW HOUSE PANELS, NEW CIRCUITS, AND NEW LIGHTS. NEW SERVICE WILL BE FEEDING EXISING UNIT PANELBOARDS.  B#18014-10000-01324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27539	18041-10000-41079	770 S GRAND AVE STE A	90017	14	129A209   223	5144012061	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.04603	-118.25748	NEW RESTAURANT IN EXISTING MIXED USED BUILDING. FIRST TIME TENANT. PLAN CHECK FOR POWER & ENERGY. 3,053 SQR FT.  BUILDING PERMIT: 18016-10000-32133	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27540	10041-20000-03786	18370 W BURBANK BLVD	91356	3	174B125   449	2160011029	[Q]C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.17159	-118.53338	T.I WORK IN MEDICAL OFFICE. INSTALLING LIGHTING AND MRI MACHINE AND TWO NEW PANEL AND CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27541	19041-20001-17659	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	01/06/2022 12:00:00 AM	ADDRESS	34.02198	-118.33376	07-31-2019 Changes to an approved set of plan, Changes include addtion of fire alarm devices and update battery calculation. All changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27542	14041-20000-16563	7315 N FIGUEROA ST #105	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.13628	-118.18852	Plan check for first time tenant.  Change of use from retail to veterinian clinic.  Install new subpanels, branch circuits, and lighting.  Plan check for power and energy. Service load based on values provided on approved set of supplemental plans 12041-10001-03794	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27543	16041-20000-10447	12139 W RIVERSIDE DR	91607	2	168B165   496	2356008010	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.15782	-118.39795	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 661 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27544	13041-10000-04468	10912 W LINDBROOK DR	90024	5	132B153   323	4363023034	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			02/21/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.05939	-118.44486	13041-10000-04468permit to be issued by plan check only. PC FOR ENERGY.EXIST 1 story mall. BEFORE:JAMBAJUICE.NOW: nekter JUICE BAR. less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27545	12041-10000-15265	25820 S VERMONT AVE	90710	15	033B197     9	7412010903	OS-1XL-O	Harbor	Wilmington - Harbor City	Harbor City, Wilmington		9800.15	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Closed	06/08/2017 12:00:00 AM	ADDRESS	33.78902	-118.29358	Plan check power for new pumps for a phosphorous removal system for lake water treatment. Site located in methane zone. Ken Malloy Harbor Park	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27546	17041-10000-38819	11022 W RIVERSIDE DR	91602	4	165B173    82	2423011027	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.15217	-118.37159	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ FT 46625.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27547	14041-20000-10443	11381 N BRADLEY AVE	91331	7	210B157    25	2523004032	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.27654	-118.42664	New 1600A service for existing manufacturing building.  Install new subpanel and reconnect some existing subpanels to new service.  No new branch circuits are installed.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27548	11041-10000-24960	1810 S SELBY AVE	90025	5	129B153   419	4321004007	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.0504	-118.43313	New 22-unit residential building.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27549	19041-20001-37620	17344 W KINGSBURY ST	91344	12	207B129   665	2733026003	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM			PC Approved	10/30/2019 12:00:00 AM	ADDRESS	34.26345	-118.51253	10-30-2019 Changes to an approved set of plan, Changes include PV Modules roof layout and equipment location. All changes has been clouded. Fess $0.00 due to California Seante Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27550	16041-20000-08863	410 S HOBART BLVD 1-67	90020	10	135B193   473	5503011022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.06674	-118.30517	PV2.  Installation of 49.6 kW DC roof-mounted PV system.  (2) 9000W and (2) 10000W inverters with (160) modules.  $0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27551	19041-10001-11769	888 S HOPE ST SUITE 121	90017	14	127-5A209  28	5144020196	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Info Complete	09/05/2019 12:00:00 AM	ADDRESS	34.0452	-118.25996	CHANGES TO APPROVED SET. CHANGES TO THE LIGHTING PLAN AND T-24 TO REMOVE L1 FIXTURES. KEYNOTES REVISED. SCOPE ALSO INCLUDES ADDING RECEPTACLES FOR GREASE PUMP, SHOWING PANELS LOCATION ON THE LIGHTING PLANS AND REMOVING ROOF MOUNTED PHOTOCELL. ALL INDOOR DAYLIGHT CONTROL NO TO BE AFFECTED BY THE ROOFMOUNTED PHOTOCELL REMOVED.   ((PC FOR FIRST TIME TENANT RESTAURANT (THE HABIT) IN A HIGH RISE MIXED USED. SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 2542 SQ. FTB# 19016-10000-09282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27552	18041-10000-12911	10258 W FOOTHILL BLVD	91342	2	210B177   210	2529001035	C2-1VL, Q, K, RA-1	North Valley			Y	1033.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Issued	04/10/2018 12:00:00 AM	ADDRESS	34.27317	-118.35331	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27553	17041-20000-03278	9321 GLORY AVE	91042	7	198B201   362	2572044007	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	PIN	34.23836855	-118.27921413	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (24) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27554	19041-20000-18037	4707 N FULTON AVE	91423	4	168B157   505	2360021045	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Apartment			05/14/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.15598	-118.42268	PLAN CHECK FOR NEW 17 UNIT APARTMENT BUILDING. T24 INCLUDED TOTAL SQUARE FOOTAGE = 13,553 SF SCOPE OF WORK INCLUDES A NEW 1200A SERVICE, 1200A PANEL, (9) 100A PANELS, (8) 125A PANELS, A 225A PANEL, AND A 5KVA INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27555	14041-20000-07939	25311 S PRESIDENT AVE	90710	15	036B193   432	7410021036	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	33.79441	-118.3044	Roof mounted PV system with tranformerless.  System size 3.27KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27556	18041-10000-45900	5970 W PICO BLVD	90035	10	129B173   363	5068012021	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.05197	-118.37021	REMOVE INDOOR AND OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27557	12041-10006-30779	"12746 W JEFFERSON BLVD ""4"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	(9/2/2015) CHANGES TO AN APPROVED SET OF PLANS.  DELTA C NOTED ON THE PLANS.  REVISIONS INCLUDE LIGHTING FIXTURES AND ENERGY CALS.  THIS IS PLAN CHECK ONLY.Plan check power and energy for Building 4. Five story parking garage building with common subterranean parking to Building 1, 2, 3, and 4. Service supply from Building 3. Site located in methane zone. Modification to separate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27558	11041-10001-26656	2334 W PICO BLVD	90006	1	129B197  1085	5056004021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.04707	-118.28751	TI in existing commercial space-new luminaires and circuitsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27559	19041-10000-39163	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	11/10/2020 12:00:00 AM	ADDRESS	33.79173	-118.23549	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK INCLUDES THE INSTALLATION OF A NEW MEDIUM VOLTAGE11.5KV/4.16 KV TRANSFORMER, SWITCHBOARDS AND PUMP MOTORS IN A REFINERY INDUSTRIAL LOCATION(HAZARDOUS CLASS 1  AREAS). SCOPE OF WORK UNDER CLOUDED AREAS ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27560	14041-20000-14051	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.0346	-118.45665	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR RIOT HEADQUARTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27561	15041-10000-20826	1300 E 1ST ST	90033	14	129A219    94	5172008902	C1-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.04745	-118.22656	ALTERATIONS IN EXISTING REPROGRAPHICS STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27562	16041-10000-07103	216 W 47TH PL	90037	9	111A203    44	5110014018	R2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	33.99993	-118.27678	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.28KW DC INTERCONNECTED WITH MSP.(15) SOLARWORLD SW 285 MONO (1)SOLAR EDGE  SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27563	13041-10000-27670	867 S WELLESLEY AVE	90049	11	129B141   624	4264017001	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Expired	10/29/2015 12:00:00 AM	ADDRESS	34.04583	-118.47528	PV1 - ROOF-MOUNTED SOLAR INSTALLATION WITH 16 MODULES , USING M215 ENPHASE MICROINVERTERS, ON STANDARD PLAN IN 2-STORY HOUSE. TOTAL AC OUTPUT = 3.45KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27564	19041-10000-26359	2245 W YOSEMITE DR	90041	14	160-5A221  43	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.13556	-118.21671	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27565	18041-20000-18168	21820 W BURBANK BLVD Ste 235	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.17228	-118.6032	TI to (E) medical office space.  Plan check for power and energy.Note: Building permit has been issued under 18016-10000-16594	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27566	14041-20000-12417	5126 N MOUNT HELENA AVE	90041	14	162A227    15	5691004026	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.14035	-118.19569	Roof mounted PV system with Enphase, model M250-60-, system size 3.5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27567	15041-20001-34595	10330 N SEPULVEDA BLVD	91345	7	204B145   217	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.25825	-118.46705	"7.11.2017 - Plan check for modifications to approved set. Sheet E-101 updated - circuiting to site lighting revised, EV panels and number of EV charger circuits updated (total of 43 EV chargers required per approved Green Building plan). Changes clouded delta ""EV"".======PC FOR ENERGY. RENOVATION OF EXISTING PARKING LOT.TOTAL AREA 267,464 SQ FT(OUTDOOR LIGHTING)B3 - 15026-10000-00527"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27568	15041-10000-26036	19200 S WESTERN AVE 1ST FL	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	33.85755	-118.30917	First floor TI.  Modify existing office layout, new restroom and break room.PLAN CHK IS FOR TITLE 24. NOTE: Inspection fees were paid under express permit #:15041-40000-27096	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27569	12041-10000-09174	347-353 E 1ST ST	90012	9	129A215     8	5161012009	[Q]C4-2D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.04965	-118.23956	"New outlets and lighting for an existing single family residence.  Load is 63 amps per applicant.  Plan check only for T-24.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27570	11041-10000-01166	10565 N NORTHRIDGE HILL DR	91311	12	207B117   321	2708015012	(T)(Q)RA-1, (T)(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth, Northridge West	YES	1131.02	Electrical	Electrical	Commercial			01/20/2011 12:00:00 AM			PC Info Complete	01/20/2011 12:00:00 AM	ADDRESS	34.26213	-118.56287	INSTALL 3 LIGHTS IN A PRIVATE STREET. PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27571	18041-10000-43891	1993 W BLAKE AVE	90039	13	148-5A213 206	5442010018	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	03/10/2023 12:00:00 AM	ADDRESS	34.10097	-118.24402	Energy plan check for an office T.I, Scope includes new lighting and equipment with a total area of 1,937-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27572	18041-10000-14816	541 S SPRING ST #112 & 113	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.04657	-118.2507	PLAN CHEK FOR T24 ONLY. (TI) CHANGE OF USE TO A RESTAURANT & EXPAND TO ADJOINING SPACE.  NEW MEZZANINE. ADD SEATING OUTSIDE TENANT SPACE. INSTALL NEW LIGHTINGS AND RECEPTACLES WHERE THE CIRCUITRY IS FROM TWO EXISTING PANELS IN THE AREA. TOTAL AREA: 1940 SQ.FT((B# 17014-10000-06338))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27573	15041-20000-16833	6609 E ELDER ST	90042	14	156A235    29	5716008040	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.12319	-118.17399	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (16) micro-inverters, and (14) modules. Old standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27574	17041-20000-26540	1446 N TAMARIND AVE	90028	13	147A191   111	5545015059	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			08/03/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.09701	-118.31892	Plan check for fire alarm system. New fire alarm system for 4-story, 41-unit apartment building over 2 levels of underground parking. 1 FACP. 129 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27575	16041-20000-41695	6321 E CHURCH ST	90042	14	157-5A233 222	5483006016	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.12458	-118.17851	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (18) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27576	17041-10000-05630	8809-8819 1/2 S BELFORD AVE Bldg#12	90045	11	096B169   870	4125009001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Issued	04/18/2017 12:00:00 AM	ADDRESS	33.95658	-118.38429	Plan check for power only in existing Building appartment. Service upgrade to 600A and new panel in each units. This is one structure with the rage of address of 8809-8819 1/2 Belford Ave	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27577	16041-20000-31273	18815 W MAPLEWOOD LANE	91326	12	207B121   782	2728031066	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.26045	-118.54372	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27578	10041-10000-05704	635 N NORMANDIE AVE 1-4	90004	13	141B193   710	5520002006	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20, 1926.10	Electrical	Electrical	Public Safety Only			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	04/01/2010 12:00:00 AM	ADDRESS	34.08267	-118.30073	FIRE ALARM SYSTEM WITH CENTRAL STATION MONITORING FOR A 4-UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27579	13041-20000-17727	432 E 103RD ST	90003	8	091-5A207 315	6063013009	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	33.94274	-118.26615	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.8KW. 13 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27580	15041-10001-34620	1141 W 2ND ST	90012	1	133-5A209 224	5152009901	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.0588	-118.25625	(((EXPEDITE FEES)))PV2 110KW ROOFTOP TRANSFORMERLESS SYSTEM. 432 MODULES AND 4 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27581	15041-20001-11515	5046 N HASKELL AVE	91436	5	171B141   348	2261032022	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2015 12:00:00 AM			PC Approved	05/06/2015 12:00:00 AM	ADDRESS	34.16249	-118.47468	PV1 SFD. TOTAL SYSTEM SIZE 6.8KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27582	11041-10000-20638	1721-1733 S PENMAR AVE BLDG 32	90291	11	111B149   378	4243001045	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.00238	-118.45724	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27583	18041-20000-48106	108 N ROSELAKE AVE 2nd flr	90026	13	136-5A205 262	5157018058	C2-1	Central	Westlake	Echo Park		2085.01	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.06778	-118.27188	ti to an existing commercial building.  adding new lighting new controls to existing panel.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27584	13041-10000-26222	100 UNIVERSAL CITY PZ stage  #31	0	4	162B177	2424044015	C2-1, PB-1					1437.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM				replacing high bay luminaires -supplied from existing ckts and lighting area ctrls  for shut-off ctrl;EMERGENCY LUMINAIRES REMAINED THE SAME PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27585	11041-10000-06659	1300 N WESTERN AVE	90027	13	147A193   247	5544031023	C2-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM			Corrections Issued	04/10/2011 12:00:00 AM	ADDRESS	34.09512	-118.30901	New CNG equipment for an existing gas station. New 600 Amp service, panel, and circuits. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27586	17041-10000-11855	3250 W SLAUSON AVE	90043	8	105B185  1434	4005005032	P-1, [Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM			Reviewed by Supervisor	04/18/2017 12:00:00 AM	ADDRESS	33.98753	-118.32923	PC FOR POWER AND ENERGY. CHANGE OF USE FROM OFFICE TO DENTAL OFFICE, TI. TOTAL AREA 2206 SQ FT.16016-10000-16666	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27587	13041-10000-35704	1015 S CROCKER ST #R8	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 330 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27588	18041-20000-35481	8812 W YATES ST	91040	7	204B189   544	2546006029	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.25647	-118.32526	Plan check for PV roof mounted system and Energy Storage System, PV System size: 15.05KW DC, 13.68KW AC with 43 PV Modules and 43 Microinverters and 1 Tesla Battery PowerWall 2.0 13.5kWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27589	16041-20001-41653	8166 N WHITSETT AVE	91605	2	192B165   726	2308018007	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.21961	-118.40508	expedite per applicantpv1install roof mounted pv system (acm) sized 12.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27590	19041-10000-26789	3324 N CHAPMAN ST Units 1-7	90065	13	156B213   282	5459009017	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Apartment			07/12/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	12/14/2021 12:00:00 AM	ADDRESS	34.12141	-118.24333	New three-story, 7-unit aparment building with recreation room with a new 600 Amp Service. Building Permit: 15010-10000-02805	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27591	11041-10000-16790	6000 N LAUREL CANYON BLVD	91606	2	177B165   683	2333013020	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.17975	-118.39631	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27592	18041-10001-25300	8502 W SHERWOOD DR	90069	5	141B173   300	4337003063	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM			PC Approved	09/10/2018 12:00:00 AM	ADDRESS	34.08477	-118.37667	09/10/2018CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE REVISION TO FIXTURE TYPE AND LOCATION. PC ONLY__________________PC FOR TENANT IMPROVEMENT FOR RETAIL STORE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA 4959 SQ.FT (INDOOR AND OUTDOOR).B# 18016-10000-21609	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27593	18041-20000-28906	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Info Complete	08/01/2018 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for Title 24 Energy only in existing space office T.I. Room 113A, 113B, and 113C Total area: 630 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27594	19041-20000-18440	2723 N NORTH MAIN ST	90031	1	136-5A223 408	5210009006	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	06/19/2020 12:00:00 AM		Issued	06/19/2020 12:00:00 AM	ADDRESS	34.06619	-118.21333	FULL POWER AND ENERGY PLAN CHECK. SCOPE OF WORK INCLUDE NEW 400A SERVICE., 400A PANEL, AND (2) 200A PANELS. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 2188SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27595	19041-10000-02424	6333 W 3RD ST #322	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	T24 FOR FARMERS TACO SHOP. TOTAL SQUARE FOOTAGE = 360 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27596	13041-10001-24730	643 N MARIE AVE	90042	14	157-5A231 111	5483012024	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.12709	-118.18162	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27597	18041-10000-02097	21530 W GLEDHILL ST	91311	12	198B105    69	2746014040	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.24116	-118.59974	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27598	14041-10000-19388	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Expired	10/18/2016 12:00:00 AM	ADDRESS	33.78054	-118.23195	PLANCHECK FOR POWER. PROVIDE POWER AND CONTROL CIRCUITS TO NEW ELEVATOR IN A REFINERY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27599	13041-10001-35693	7337 N CALDUS AVE	91406	6	186B129   989	2228003025	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.20412	-118.5158	Expedited RSES plan check per applicant request. {{PV1, Install 3.18 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (12) modules: Suniva OpT265-60-4-1B0.***This building already has a solar array permit with # 13041-20000-26693 with system size 3.5 kw DC.***}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27600	13041-10000-10688	20520 W NORDHOFF ST	91306	12	195B109    72	2780001050	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	PIN	34.23141269	-118.58091638	New fire alarm system for 2-story commercial building.  78 devices, 1 new panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27601	11041-10000-20651	1006-1012 E ELKGROVE AVE BLDG 6	90291	11	111B145   749	4243002067	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.00013	-118.45947	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27602	17041-10000-35964	1104 W BROWNING BLVD	90037	8	114B197    89	5037025021	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.01191	-118.29433	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27603	16041-10000-17702	800 S GRAND AVE	90017	14	129A209   243	5144019017	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.04552	-118.25803	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A DRUG STORE ON A NEW 4 STORY PARKING STRUCTURE OVER RETAIL (CVS PHARMACY).SCOPE INCLUDES A NEW 800A 3 PHASE 4 WIRE DISTRIBUTION BOARD, 3 NEW SUBPANELS, AND LOAD EQUIPMENT. TOTAL AFFECTED AREA IS 15075 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27604	15041-10000-18726	12460 W OSPREY LANE 1-3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'A'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'A' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27605	17041-10000-10416	19849 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.23209	-118.56589	Plan check for  Title 24 only in existing space replace existing fixtures with LED fixtures. Total area: 7,000 sqf t	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27606	17041-20001-14047	1044 S TIVERTON AVE	90024	5	132B153   151	4360002006	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	34.06077	-118.443	Revisions to approved plans.  Scope of work for interior improvements to common areas and guest rooms reduced.  Only improvements to units is now additional air-conditioning loads.   (((Plan check for power only.  Service upgrade to 600A for (E) hotel.  (4) 75 kVA transformers and (5) new panels.Note: Title 24 has been plan checked and approved under application 17041-20000-32135. Title 24 permit fees have been included on this application.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27607	19041-10000-15877	4177 W WASHINGTON BLVD	90018	10	126B185   973	5072001034	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.04004	-118.33063	T-24 PLAN CHECK FOR A TI OF AN EXISTING STARBUCKS. ( NO CHANGE OF USE ). SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1516 SQ.FTB# 19016-10000-11431	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27608	15041-10000-06214	12024 W ELKWOOD ST	91605	6	189B165   776	2310018012	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21286	-118.39525	PV1.  Install 6.213 kW roof-mounted, utility-interactive PV system.  PV standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27609	16041-20000-36391	14355 W ARMINTA ST	91402	6	189B153   973	2212028900	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.21315	-118.4446	remove existing hid fixtures and replace with new led fixtures outdoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27610	13041-10000-07361	2720 W BEVERLY BLVD	90057	13	136-5A203  46	5155015014	C2-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			PC Info Complete	05/17/2013 12:00:00 AM	ADDRESS	34.06999	-118.27835	13041-10000-07361PLAN CHECK FOR ENERGY FOR EXISTING SMART & FINAL. SQRFT 16600. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27611	15041-10000-30078	12100 W OLYMPIC BLVD #150	90064	11	123B149   575	4259025019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.03215	-118.45396	TI. PC for energy only to an existing (4) story bldg. Scope: converting a gym into a shell space for future tenant. SQFT = 8795.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27612	18041-10001-11448	1934-1936 N DRACENA DR	90027	4	150B197   696	5590013007	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM			PC Approved	04/05/2018 12:00:00 AM	ADDRESS	34.10638	-118.29	PC FOR CHANGES TO APPROVED PV PLAN. SCOPE OF CHANGE TO REFLECT FIELD INSTALLATION OF 7.6 KW INVERTER (TO REPLCE 5KW INVERTER).  ADDITIONAL PERMIT FOR THE NEWLY SIZED INVERTER UNDER 10002(1)INVERTERS-SOLAREDGE SE7600H-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27613	16041-10000-34545	11454 N BALBOA BLVD	91344	12	213B133   721	2682028035	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.27892	-118.50188	PC for energy only. Remove HID fixture and replace with new LED fixture. Total sqft = 18700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27614	14041-10000-01677	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.21328	-118.45279	"INVESTIGATION FEE DUEPlan check for power and energy. Total Area for Indoor and outdoor lighting is 56695 sq ft. (31720 interior + 24975 exterior). New electrical systems throughout for fire damaged building. Not methane. GREEn building. Series rated for 65k for available 36KA.""COMPLY WITH DEPARTMENT ORDER effective date 09/05/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  CEIS Case Number is 510596."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27615	18041-10000-11801	18133 W VENTURA BLVD 4TH FLR	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.16603	-118.52861	FULL PC FOR A 4TH FLOOR TI OF (E) 4 STORY CORE AND SHELL BLDG WITH OUTPATIENT MEDICAL OFFICE W/EXAM ROOMS. TOTAL SQ. FT. 4868.Bldg Permit # 13020-10K-00933	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27616	13041-10001-30869	20332 W VIA BOTTICELLI	91326	12	219B113   257	2701059049	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.29746	-118.57668	Expedited RSES plan check per applicant request. (((PV1, Install 9.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 39 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27617	19041-10001-13422	8211 S CENTRAL AVE	90001	9	099B209   563	6029013004	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2398.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	33.96433	-118.25658	PC only to PV. the approved set was done online . Approved set permit # - 19041-9000-13422. fees are paid under original online set.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27618	14041-10001-10073	17613 W ROSCOE BLVD	91325	12	192B129   272	2787016007	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM			PC Approved	05/08/2014 12:00:00 AM	ADDRESS	34.22117	-118.51696	EXPEDIE FEESROOF-MOUNTED 17.28KW DC PV SYSTEM USING M250 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27619	14041-20000-28011	5840 W SANTA MONICA BLVD	90038	13	144B189  1082		C2-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM			PC Approved	11/03/2014 12:00:00 AM	ADDRESS	34.09057	-118.31666	T.I. CHANGE FROM RETAIL TO OFFICE. NO CHANGE IN LOADS. NEW LIGHTING. PC FOR T24 ENERGY ONLY. PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27620	15041-10000-05848	360 E 62ND ST	90003	9	105B205   761	6006021001	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Expired	03/23/2017 12:00:00 AM	ADDRESS	33.98325	-118.26744	PV1.  Install 7.776 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27621	19041-10000-10664	9837 N GLENOAKS BLVD	91352	6	201B169    63	2537022001	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Issued	03/26/2019 12:00:00 AM	ADDRESS	34.24824	-118.38619	Remove HID fixtures and replace with new LED fixtures (Indoor Only), - T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27622	17041-10000-25672	4151 W PROSPECT AVE BLDG A	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	"PC FOR POWER. RELOCATING 1200 A  SWITCHBOARD AND INSTALLING NEW 750KVA TRANSFORMER IN BUILDING  ""A"" BASMENT.SCOPE INCLUDES NEW TRANSFORMER AND CONDUTORS TO RELOCATED SWITCH BOARD."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27623	17041-30001-04323	6600 N TOPANGA CANYON BLVD SPACE 43	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Approved	05/31/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Revision to approved set, noted under Delta 1 only. Revise luminaires, lighting floor plan, and T24 calculation accordingly. This is plan check only, permit will be covered under the master plan# 17041-10000-04323 <<T-24, PC FOR ENERGY ONLY. TI TO AN EXISITING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGTHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS TI  Remodel of existing retail space inside the mall.  TOTAL AFFECTED AREA IS 3820 SQ. FT. B#17016-40000-02720 SQ. FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27624	12041-10000-26781	6148 W PICO BLVD	90035	10	129B173   180	5068001005	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.05298	-118.37549	PC FOR T24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT OF EXISTING RETAIL TO NEW DRY CLEANER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27625	18041-20000-34316	7428 N VARNA AVE	91605	2	186B157   316	2328029010	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.20563	-118.42457	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27626	19041-20000-07785	20626 W LEMARSH ST	91311	12	204B109   276	2741026007	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.25532	-118.58271	Installation of 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27627	19041-20000-17441	6065 W FOUNTAIN AVE	90028	13	144B189  1074	5545013059	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Issued	11/08/2019 12:00:00 AM	ADDRESS	34.09455	-118.32157	ti to an existing motion picture production building.  newly connecte load >400 amps.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27628	18041-20000-05415	11110 N RUFFNER AVE	91344	12	210B137   408	2682019001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Issued	02/13/2018 12:00:00 AM	ADDRESS	34.27225	-118.49763	Plan check for power only. Project scope is the addition of (2) PowerWalls to an existing roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27629	17041-20000-45309	10241 N MASON AVE	91311	12	204B109   515	2741025182	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	PIN	34.25646128	-118.58026748	Change of use from full service to self service car wash.   New 600A 480Y/277V distribution with existing service.  Plan check for power and energy.  Building permit under 16014-30000-01102	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27630	18041-10000-23453	1531 S WALKER AVE	90731	15	012B193   443	7459029023	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	33.7301	-118.30354	Plan check for a PV1 3.8KW AC / 4.67 KW DC roof mounted system. Scope includes (17) modules, and optimizer, (1) inverter. interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27631	15041-20000-15345	1840 S CENTURY PARK EAST 18 FLOOR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.06188	-118.41473	Title 24 plan check only.  Total area = 380 sq. ft.  T.I. to restroom in existing highrise building.  New general lighting and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27632	14041-20000-17342	624 S GRAND AVE suite 2950	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	Plan check for energy only. Installation of new lighting (incl. emergency) on 29th floor of high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27633	17041-20000-09519	3700 S BAGLEY AVE	90034	5	120B165   223	4313020056	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.02765	-118.39659	Plan check for the replacement of the FACP of an existing fire alarm system for an apartment building. Fire alarm devices existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27634	10041-20000-11408	2029 S CENTURY PARK EAST 36th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM			PC Approved	06/15/2010 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check T-24 Energy (general/emergency) lighting for corridor space on the 36th floor. All circuits and auto shut-off are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27635	18041-10001-27043	3800 S VERMONT AVE	90037	9	117B197   615	5037028912	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Closed	03/27/2024 12:00:00 AM	ADDRESS	34.01684	-118.29134	CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES REDESIGNING T24 FORMS AND REVISING LIGTHING PLAN FOR A NEW ADDITION FOR LUCAS GALLERY, TOTAL AFFECTED AREA IS 10,000 SQFT. ALL CHANGES ARE CLOUDED UNDER DELTA  5,6,2,10,8,9, & 4. ADDING TWO NEW PANELBOARDS, AND REVISING FLOOR PLANS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27636	18041-10000-05889	2595 S HOOVER ST A	90007	8	123A201    42	5055022036	C4-1VL-O, QC1.5-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	04/02/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.03206	-118.28429	PC for power and energy for first time tenant for Coffe shop. Installing three new panels, lights, receptacles and circuits. Total area 2274sqft. B#17016-10000-15578. Note: Partial fees paid under 17041-10000-35030.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27637	19041-20001-03910	2131 S DUXBURY CIR	90034	5	126B165   121	4309009021	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.04418	-118.39609	Expedite per applicant request Plan check for PV roof mounted system, System size: 9.9KW DC, with 30 PV Modules and 1 inverter(7.6KW) connected to 600A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27638	11041-20000-11331	801 S GRAND AVE #525	90017	9	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	08/25/2011 12:00:00 AM	ADDRESS	34.04581	-118.25842	PLAN CHECK T24 ENERGY(GENERAL/EMERGENCY) LIGHTING TI FOR SUITE #525. PERMIT TO RELOCATE LIGHT FIXTURES AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27639	16041-10000-01790	1901 S RIDGELEY DR	90019	10	126B177   938	5064007008	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Expired	02/15/2018 12:00:00 AM	PIN	34.04083961	-118.35891587	PV1, ROOF MOUNTED SOLAR SYSTEM USING MICRO INVERTERS. (28) MODULES AND (28) MICRO INVERTERS. TOTAL SIZE IS 7KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27640	19041-10000-02901	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A CUSTOMER EXPERIENCE CENTER. A-OCCUPANT LOAD > 100. TOTAL AFFECTED AREA IS 4119 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27641	18041-10000-02871	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	PIN	34.0586034	-118.41904766	"[Refer to Delta 25 under permit# 14041-10006-26004] Revision to approved set noted on delta-34: Add new circuitry and tenats' loads (WALL SHOPS) to existing Dist. board ""MB"" that's fed from existing MS- ELA33 through an existing 750KVA xfrmr. Revise single line diagram,  revise panel schedule ELA33LD1, revise MB load schedule and MS-ELA33 load schedule accordingly."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27642	17041-20001-07052	2006 S PARNELL AVE	90025	5	129B157   548	4321006042	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2017 12:00:00 AM			PC Approved	03/13/2017 12:00:00 AM	ADDRESS	34.05023	-118.42762	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 400A MSP.System size: 8.96kW ungrounded. (28) 360W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27643	18041-10000-27192	7930 N MASON AVE	91306	3	189B109   424	2107024029	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.21478	-118.57959	Install Fire alarm system, (1) panel, (38) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27644	16041-20000-26350	1056 S ALVIRA ST	90035	5	132B173   675	5087013009	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.05725	-118.37096	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system.(35) 290W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27645	11041-10000-05852	4020 W 3RD ST	90020	10	135B193   213	5502001010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM			PC Approved	04/06/2011 12:00:00 AM	ADDRESS	34.06886	-118.30114	T.I.  EXISTING CAR WASH, ADDING ADDITIONAL LIGHTING FIXTURES.  TITEL 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27646	15041-10000-34770	6121 W SUNSET BLVD	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	CHANGE OF CONTRACTOR, RESUBMITTAL PER APPLICANT.  PLAN CHECK FEES PAID UNDER APPLICATION # 15041-10000-27112.  INSTALLATION OF DISTRIBUTION AND PANELBOARDS IN VACANT BUILDING.  PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27647	19041-10000-01058	9164 W PICO BLVD	90035	5	132B169   891	4306004002	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.05507	-118.39143	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27648	11041-20000-27234	8496 S OSAGE AVE	90045	11	096B173    80	4127024018	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	33.96159	-118.37861	target dept store customer required complete plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27649	10041-10000-20720	325 S BOYLE AVE 1st floor	90033	14	127-5A221  72	5174012009	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.40	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	07/18/2011 12:00:00 AM	ADDRESS	34.04403	-118.2199	Emergency lighting plan check for lobby and office areas as shown on page E-4.0.  The applicant provided a Certificate of Occpancy to show that the building is an I2 Occupancy that is not required to comply with part 6 of the California Energy Standard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27650	15041-20000-35661	4421 N NOGALES DR	91356	3	168B121   569	2177009016	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.15263	-118.54618	Plan check for PV roof mounted system. System size 13.0kW and  43 modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27651	19041-20000-14118	781 N LINDA FLORA DR	90049	5	141B145   363	4368022010	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Issued	04/17/2019 12:00:00 AM	ADDRESS	34.07976	-118.46657	PV1.  Install 16.10 kW roof mounted grid tied PV system.  (46) modules and (2) 7.6 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27652	14041-20002-12041	12655 W SANDHILL LANE UNIT 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	33.97753	-118.41457	REVISIONS TO AN APPROVED SET OF PLANS.  REMOVAL OF THE SMS MONITORING SYSTEM.pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #2. 2/3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27653	17041-10002-25142	1101 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   147	5037025019	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Apartment			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.01106	-118.29422	CHANGES TO APPROVED SET TO REFLECT CORRECT SYMBOL ON SYMBOL LIST ONLY.THIS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27654	18041-20002-16002	4754 N AMIGO PL	91356	3	168B125   161	2176017003	RA-1	South Valley	Encino - Tarzana	Tarzana	Yes	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Issued	09/18/2018 12:00:00 AM	ADDRESS	34.15926	-118.53788	9/18/2018changes to an approved set of plans.  changes to relocate equipment and add new load center.((((Plan check for PV roof mounted system, System size: 16.6 kW with 59 modules and 3 inveters(3.8kW, 5.2kW and 7.6kW) on SFD.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27655	19041-10000-47507	1230 W ANAHEIM ST	90744	15	030B201   243	7416008001	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Issued	11/19/2019 12:00:00 AM	ADDRESS	33.77889	-118.27785	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27656	12041-20001-03476	560 S ST LOUIS ST	90033	14	126A221   109	5183019032	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			PC Approved	02/22/2012 12:00:00 AM	ADDRESS	34.03916	-118.21715	energy plan check office revision	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27657	13041-20000-17780	1977 S DURANGO AVE	90034	5	126B169   509	4302009001	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	34.04243	-118.38808	PV1 SINGLE FAMILY DWELLING. 400A SERVICE. NONSTANDARD PLAN. USING MICROINVERTER ENPHASE M215. TOTAL SYSTEM SIZE 7.3 KW. USING 34 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27658	15041-10000-11985	100 WORLD WAY TERM-7	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	AT LAX, INSTALLATION OF ILLUMINATED SIGN NUMERALS IDENTFYING THE INDIVIDUAL TERMINAL .EACH SIGN NUMERAL WILL BE SUPPLIED FROM A 20-A BRANCH CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27659	15041-10000-34601	8015 N DEERING AVE	91304	3	189B105   165	2109001015	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.21585	-118.59519	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27660	17041-10000-31281	10446 N SCOVILLE AVE	91040	7	204B189    83	2560009013	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.2592	-118.31389	PC FOR 600A SERVICE UPGRADE. THIS IS SERVICE CONSOLIDATION. REFEEDING EXISTING PANELS TO NEW SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27661	10041-20001-08221	2434 S PURDUE AVE 1-24	90064	11	123B153   431	4260038036	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM			PC Approved	08/02/2010 12:00:00 AM	ADDRESS	34.03341	-118.4398	PLAN CHECK ONLY. DELTA 1 REVISION ONLY. CHANGE 60A OCPD TO 40A OCPD IN PANEL. PV SYSTEM FOR APARTMENT BUILDING. 7KW SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27662	10041-10000-05494	12405 W SYLVAN ST	91606	2	177B165    33	2333007026	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	01/12/2011 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	34.18497	-118.4032	Plan check power for 28.12KW Photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27663	12041-10001-03286	718 S HILL ST HALL/#402-mezz lev	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	05/22/2012 12:00:00 AM	ADDRESS	34.04527	-118.25477	TITLE 24 PLAN CHECK FOR NEW LIGHTING IN THE CORIDORS ON THE 4TH FLOOR AND THE MEZZANINE LEV. PERMIT WAS OBTAINED FOR THE WORK ON THE 4TH FLOOR ON SEPARATE  APPLICATIONRELOCATE (8) RECEPTACLES AND (2) CIRCUITS FOR UNIT #402.  RELOCATE (8) LIGHTS UNDER EXISTING CIRCUITS FOR UNIT #402. ADD (4) LIGHTS IN HALLWAY UNDER EXISTING CIRCUITS.  (1 OF 2 W/ PERMIT #12044-10000-01550)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27664	18041-20000-06767	823 N FULLER AVE	90046	5	141B181   147	5526006033	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Apartment			02/23/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.08595	-118.35001	New 6 unit apartment building 600 amp service.  plan check for power and energy.(B# 16010-30000-05380)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27665	16041-20000-41010	10263 ANGEL LANE	91331	7	204B165   441	2537004051	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25715673	-118.40504247	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27666	19041-10000-34992	2712 S CAROLINA ST	90731	15	009B197  1003	7465014029	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	33.7194	-118.2905	[EPLAN] PLAN CHECK FOR NEW ESS CONNECTED TO EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27667	18041-10000-20111	3415 S SEPULVEDA BLVD	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.02055	-118.42347	NEW LIGHTING SYSTEM IN THE COURTYARD AND EXTERIOR STAIRCASES OF AN OFFICE BUILDING.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27668	15041-20000-16263	936 S OLIVE ST UNIT 256	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #2 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27669	13041-20000-00615	9542 W CHEROKEE LANE	90210	5	150B165   106	4387032027	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.10999	-118.40353	New 10kw Photovoltaic system for an existing single family dwelling.  System uses Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27670	16041-10000-32604	7401 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	33.94379	-118.42359	PC for temp generator step up to 4160 and provide power to building. special ups project asin to MZ	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27671	14041-10000-31742	819 N LA BREA AVE	90046	5	141B181   189	5525004008	C4-1VL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	PIN	34.08582658	-118.34439144	Plan check for Title 24. Total lighting area (indoor and outdoor) = 8,488 sq. ft. Project is a tenant improvement to an existing commercial space (retail).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27672	18041-20000-42717	3936 S WASATCH AVE	90066	11	111B153   686	4235016016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.00037	-118.43312	pv1install roof mounted pv system sized 3.0KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27673	18041-10000-06100	8985 W VENICE BLVD #A3	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.02733	-118.39241	PC for T24 only for new lighting in retail TI. Installing new lights, receptacles and panels. Total area is 29508sqft. Installed load under 400A. B# 18016-40000-03761	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27674	19041-20001-36740	5727 N CANOGA AVE BLDG 6	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	10/14/2020 12:00:00 AM	ADDRESS	34.17529	-118.5978	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27675	17041-20001-32161	12112 W LAUREL TERRACE DR	91604	2	162B165   938	2376015005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.13797	-118.39635	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD. Derating main to 175A.11.4kW ungrounded system. (47) 325W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27676	10041-10000-18696	21051 W WARNER CENTER LANE # 200	91367	3	174B105    23	2149017008	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	12/14/2010 12:00:00 AM	ADDRESS	34.17485	-118.59143	T.I. REMODEL IN EXISTING OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27677	17041-10000-29451	11402 N ILEX AVE	91340	7	213B153   158	2616018032	M1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.27719	-118.43544	REMOVE EXISTING (30) HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 33050 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27678	14041-20000-04602	19871 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.23203	-118.56649	Change of use from existing office/warehouse to new medical office (2 levels).  Install new subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27679	12041-10000-12068	618 N NORTH MAIN ST	90012	14	132A215    44	5408011907	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/31/2012 12:00:00 AM	ADDRESS	34.0575	-118.23832	Plan check for energy. 1178 sqft conditioned space. Occupancy less than 100 and load is less than 400A. Change of use from retail to restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27680	10041-10000-14602	5111-5125 S MAIN ST	90037	9	111A203   428	5110025002	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Apartment			07/28/2010 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	33.99626	-118.27417	News residential building with 4 story and 46 units (Affordable for senior household).  Install new service, panels, and branch circuits.  Plan check for power and energy.  Variance for separate fire alarm submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27681	12041-10000-28722	14650 W SHERMAN WAY	91405	6	183B149   112	2219007027	R5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.20013	-118.45208	FIRE ALARM SYSTEM REPLACEMENT ON WEST VALLEY TOWER. 1 PANEL AND 304 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27682	12041-20000-14313	8501 S PERSHING DR # 3	90293	11	096B153  1024	4116024033	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	33.95597	-118.44237	T-24 lighting plan check for remodeled restaurant in space 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27683	17041-10000-27784	735 S FIGUEROA ST	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.04878	-118.26079	PC FOR REPLACMENT OF 400A BREAKER ON MAIN SWITCH BOARD WITH 800A BREAKER FOR FUTURE TENANT. SCOPE INCLUDES NEW CONDUCTORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27684	18041-20000-27441	1710 N MICHELTORENA ST	90026	13	145-5A205 351	5431026013	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Issued	07/23/2018 12:00:00 AM	ADDRESS	34.09182	-118.27293	PV1.  Install 6.175 kW roof mounted grid tied PV system.  (19) modules with (2) 3.3 kW string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27685	18041-10002-27023	425 E SWINFORD ST	90731	15	021B201   197	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	33.7497	-118.27718	Re-plan check for a lost set of plans. Plan check only. (((((NEW PV SYSTEM MOUNTED ON CARPORTS WITH 3080 PV MODULES AND 34 INVERTERS WITH 480 VOLT OUTPUT. SYSTEM SIZE  1.34 MWDC/  980 KWAC<<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03433	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27686	17041-10000-24503	12804 W RAYMER ST	91605	2	186B161   548	2324005032	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.20407	-118.41179	T-24, PC FOR ENERGY ONLY. REPLACING EXISTING FIXTURES WITH LED FIXTURES FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 55500 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27687	16041-20001-45453	1470 S BEVERLY DR 1-39	90035	5	129B165   132	4306008025	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Approved	07/10/2017 12:00:00 AM	ADDRESS	34.05309	-118.39518	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27688	11041-10000-00659	3767 W SANTA ROSALIA DR	90008	8	114B185   328	5032002046	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	ADDRESS	34.0097	-118.33908	REMODEL OF EXISTING RESTAURANT; EPC IS FOR POWER AND ENERGY.  APPLICANT IS REQUESTING PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27689	10041-20000-16425	4374 N TROOST AVE	91604	2	165B169   357	2365021006	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Apartment			08/20/2010 12:00:00 AM	08/20/2010 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.14953	-118.38649	fire alarm 6 units apartments	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27690	12041-20000-02638	1220 N HIGHLAND AVE 2nd floor	90038	4	144B185   386	5532005038	C2-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Approved	02/09/2012 12:00:00 AM	ADDRESS	34.09323	-118.33841	T24 and emergency lighting plan check for remodel on the second floor.  Less than 400 amperes of added or modified load. (Plan check only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27691	19041-10000-38681	724 S LA BREA AVE Unit # R13	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Info Complete	10/03/2019 12:00:00 AM	ADDRESS	34.06145	-118.34406	Energy plan check for a change of use from retail to dance studio. Scope includes new lighting and equipment with a total lighting area of 4292-SQ FT.Plan check only.. Contractor pulled express permit under application #19041-20000-41532 and had been finaled by Inspector Robert Thomas.  Information verified by owner.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27692	18041-10000-39532	950 W 190TH ST	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Issued	01/15/2019 12:00:00 AM	ADDRESS	33.85814	-118.29219	PLANCHECK FOR POWER AND ENERGY. INDOOR + OUTDOOR LIGHTING. REPLACING HVAC UNITS. LOADS EXCEED >400AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27693	10041-10000-10792	14006 W RIVERSIDE DR 249B	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	09/22/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24 lighting plan check for food service space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27694	16041-10000-06364	1649 W 59TH PL	90047	8	105B193   192	6002009018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	33.98682	-118.30628	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac. (12)MODULES-KYOCERA #KU2606XPA(1)INVERTER- ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27695	17041-10000-06195	555 W 5TH ST STE 600-& 670	90013	14	130-5A211 161	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR SUITE 600 AND 670. TOTAL AFFECTED AREA IS 1719 SQ. FT.  b#16016-10000-15375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27696	10041-10002-22525	613 S GAYLEY AVE	90024	5	135B149   241	4363006020	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.06762	-118.44862	REVISION  TO APPROVED  PLANS.  CHANGES TO LIGHTING, ADDITIONAL LOADS, AND NEW MECHANICAL EQUIPMENT TO PANELS.  ALL DELTA D AND DELTA 2 ARE THE CHANGES.  APPROVED SET OF PLANS FOR PCIS# 10041-10000-22525 PROVIDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27697	15041-20000-09438	5805 N HILLVIEW PARK AVE	91401	2	174B157   158	2343019023	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.1759	-118.42522	PV1 SFD. TOTAL SYSTEM SIZE 10KW USING 2 CENTRAL INVERTERS. STANDARD PLAN. TOTAL OF 51 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27698	14041-10006-00855	6417 W SELMA AVE	90028	13	148-5A187 302	5546007022	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.09988	-118.33008	06/27/2017 PLAN CHECK ONLYREVISIONS TO PERMITTED SET OF PLANS:  Elevator # 4 supplied from EM  distribution board DBES Smoke control fire dampers supplied from panel EL1 Adjusted elevator fuses ampere ratings  Adjusted load summaries for DBES and generator distribution board	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27699	15041-10000-14982	443 W 1ST ST	90731	15	018B201   716	7449024006	[Q]RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	33.74317	-118.28666	PV1 Standard plan with 4.2KW ac roof mounted system, equipment mainly include:  (17) Kyocera modules and (1) ABB PVI-4.2 OUTD inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27700	19041-20000-05427	8201 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	08/20/2020 12:00:00 AM		Issued	08/20/2020 12:00:00 AM	ADDRESS	34.21793	-118.6063	PLAN CHECK FOR POWER ONLY SERVICE UPGRADE TO 2500 AMP 480/277 3PH, 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27701	15041-10000-43080	1450 S LA CIENEGA BLVD	90035	10	129B173   389	5068003055	C2-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.05187	-118.37594	T-24, TI TO AN (E) OFFICE SPACE AND OUTDOOR LIGHTING. SCOPE OF WORK INCLUDES NEW LIGHTING IN AN OFFICE ROOM, OUTDOOR LIGHTING AND NEW A/C EQUIPMENT. TOTAL SQ. FT. 520.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27702	15041-20001-36439	1030 S ROBERTSON BLVD	90035	5	132B169   296	4332016042	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM			PC Approved	11/20/2015 12:00:00 AM	ADDRESS	34.0582	-118.38345	EXPEDITE PER APPLICANT REQUEST.PV2. NEW ROOF-MOUNTED SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 15KWac.(46) MODULES-SILIKEN #KLK60P6L-240(3) INVERTERS-SUNNY BOY 5000-US(1) 100A SUBPANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27703	17041-10000-38789	865 S FIGUEROA ST 27TH FL	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	alterations in existing office-new power and lighting circutsPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27704	18041-20001-14223	8554 N NEVADA AVE	91304	12	192B101   107	2010015001	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM			PC Approved	04/21/2018 12:00:00 AM	ADDRESS	34.22558	-118.60887	Expedite fee per applicant request. PV1.  Install 15.2 kW AC roof mounted grid tied PV system.  (47) modules with (2) 7.6 kW AC rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27705	19041-10000-24178	2817 S HOPE ST	90007	9	121-5A203 220	5122017908	PF-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.02508	-118.27515	PC (PWR AND ENERGY) FOR A BRIDGE HOME EMERENCY HOMELESS SHELTER 1-STORY, SERVICE SIZE IS 400A, 480/227V,3PH, 4WIRES. AREA OF SCOPE 28,284SQFT, METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27706	17041-10000-23619	3361 N ANDRITA ST LOT 9	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 9 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05791	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27707	16041-10000-09816	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES ADDING 3 NEW MOTORS, PC AIR, NEW PORTABLE WATER CAB CIRCUITS AND REPLACING 3 PBB UNITS. AT LAX TERMINAL 2. CONNECTED AMPS IS > 400AMPS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27708	18041-30000-15559	4505 S SLAUSON AVE	90230	11	111B161   968	4218001044	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			04/26/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	33.99739	-118.41328	Plan check for a fire alarm system for a 23-unit apartment building. Fire alarm consists of (1) FACP and (46) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27709	16041-20000-02883	7900 N BALBOA BLVD BLDG 'I'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Issued	02/04/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	Plan check for power and energy Aircraft Hangar Building 'I' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' I' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27710	13041-10000-32206	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.93845	-118.42964	INSTALLATION OF 1600A 480V POWER FOR ROCK CRUSHING PORTABLE EQMT (applicant says equipment approved by Electrical Test Lab - to be verified). Methane zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27711	17041-10000-03458	830 S OLIVE ST	90014	14	127-5A209  95	5144018026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.0443	-118.25741	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 93 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27712	16041-20001-34474	4550 N VAN NUYS BLVD Suite E	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	03/03/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to the emergency lighting power system.*****Previous Work Description*****Plan check for energy only. TI to restaurant - Burger Lounge. New lighting (including emergency) - T24. 1,818sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27713	13041-20000-17775	425 S BROADWAY	90013	14	129A211    35	5149025001	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.049	-118.25009	EXISTING RETAIL SPACE CHANGE OUT LIGHTING FIXTURES FOR ENERGY EFFICIENT. NEW LIGHTING. PLAN CHECK FOR T24 ENERGY ONLY. TOTAL AREA 2808 SQFT. FIXTURES ONCTAIN BUILT IN OCCUPANCY SENSORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27714	14041-20000-09450	13753 N BRUSSELS AVE	91342	7	228B157   498	2503012025	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.322	-118.42839	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27715	19041-20000-12649	1400 S BROADWAY	90015	14	124-5A207 215	5133008007	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.03532	-118.26243	New one-story commercial building (child daycare).  200A 240/120V 1ph-3w service.  Plan check for power and energy. Building permit under 19010-10000-01347.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27716	15041-20002-27869	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.06725	-118.41704	[[[2/2/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. DELTA 4 CHANGES. REMOVING PUMPS  HTM1 - HTM8 ]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27717	19041-10000-19973	5901 W CENTURY BLVD 1560	90045	11	090B169    15	4124030042	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE SUITE #1560. TOTAL EFFECTED AREA 1266 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27718	16041-20000-16141	6171 W CENTURY BLVD Ste 100	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	TI to (E) commercial office space in lowrise commercial office building.  Plan check for energy.  2332 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27719	14041-10000-04040	401 S GRAND AVE	90071	14	130-5A211  51	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.05156	-118.2528	PLANCHECK FOR POWER AND ENERGY. NEWLY CONNECTED LOAD > 400 AMPS. change of use: TENANT IMPROVEMENTS CONVERTING FORMER BANK SPACE TO RESTUARANT USE (Pez Cantina). Not methane. Hirise. Changes on plans include: exit signs to have dual inputs, inspector to verify UL listing of fixtures and return for supplemental plan check when manufacturer/model is identified, panel PHP->A1H, and Grand Ave (not St.).BUILDING P# 14016-10000-02672	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27720	09041-20001-24367	3327 E SABINA ST Bldg B	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			07/11/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 4 Revision to approved plans. Change from CU feeders to AL feeders for New Apartment Complex w/ multiple buildings (Bldg B) 2 of 2 Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27721	18041-10000-46118	4960 E HUNTINGTON DR SOUTH	90032	14	144A235   333	5218009020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	12/29/2020 12:00:00 AM	ADDRESS	34.08745	-118.17453	PLAN CHECK FOR TITLE 24 FOR - CHANGE OF USE FROM RETAIL TO RESTAURANT; TI, BUILDING WALLS, CLG; PLUMBING AND ELECTRICAL TO ACCOMMODATE NEW DONUT SHOP - TOTAL AFFECTED AREA = 1661 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27722	14041-10001-14513	1243 S WELLESLEY AVE 1-11	90025	11	126B145   494	4267036012	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM			Reviewed by Supervisor	06/13/2014 12:00:00 AM	ADDRESS	34.0418	-118.46837	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{[PV1, INSTALL 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27723	17041-10001-22691	11327 N BERTRAND AVE	91344	12	213B125   614	2715019027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South	YES	1112.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			Reviewed by Supervisor	07/10/2017 12:00:00 AM	ADDRESS	34.27666	-118.52531	EXPEDITE PER APPLICANT REQUEST.PC FOR ROOF TILED PV SYSTEM. USING 439 MODULESS (TILES) AND 2 INVERTERS SYSTEM SIZE 10.4KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27724	15041-10000-43454	18527 W DEVONSHIRE ST	91326	12	204B125   100	2728028025	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	PIN	34.25832638	-118.53687182	T-24, TI TO AN (E) OFFICE SPACE. SCOPE OF WORK INCLUDES THE ADDITION OF CUBICLES LESS THAN 5FT 9 INCHES, NEW LIGHTING AND RECEPTACELES. Total sq ft= 2058	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27725	13041-10000-29309	2937 S BRONSON AVE	90018	10	120B185   204	5051028009	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.02835	-118.33401	PV1, installing ROOF TOP solar system for 1 or 2 dewelling family house, m215 MICRO INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27726	13041-10000-28789	16745 W TIM LANE	91406	6	180B137  1008	2231018***	RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.19363	-118.49846	PV1, ROOF-MOUNTED 4.25KW PHOTOVOLTAIC SYSTEM. TRANSFORMERLESS WITH (17) MODULES: TRINA SOLAR #TSM-250PA05.18(1) SOLAREDGE #SE3800A-US(17) SOLAREDGE OPTIMIZERS: POWERBOX, 250W, #OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27727	18041-10000-16711	1031 N SWARTHMORE AVE #1-106	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.0482	-118.52534	"PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR RESTAURANT ""BLUE RIBBON BURGER"" WITHIN PACFIIC PALISADES. NEW CONNECTED LOAD IS APPROX. 158 KVA TO EXISTING 6000A DISTRIBUTION EQUIPMENT. TOTAL AFFECTED AREA = 551 SQ. FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27728	13041-10000-35559	12412 W VENTURA BLVD UNIT #1-UNIT #2	91604	2	162B165   288	2369001021	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.14268	-118.40345	NEW 600A SERVICE, FOR A NEW DENTAL OFFICE, AND TWO OTHER FUTURE SPACES. TITLE 24 PC APPROVED UNDER: 13041-10000-25811EXPERESS PERMIT WAS ISSUED UNDER 13041-20000-08296 FOR 20 CIRCUITS, 2 @ X-RAY EQUIP AND 2 PANELS.  THIS PERMIT COVERS THE REMAINING ITEMS INCLUDING 4 CIRCUITS IN THE HOUSE PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27729	13041-10000-30921	831 E 20TH ST	90011	9	121-5A209 220	5131006017	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.0262	-118.25658	PV1. ROOFMOUNTED. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 3.67 KW.(17) SILVANTIS F265 MODULES(17) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27730	17041-20000-24803	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check for power and energy. TI to existing medical office in basement (Kaiser Permanente). 1,899sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27731	13041-10000-25067	16101 W VENTURA BLVD STE 125	91436	5	168B141   539	2260023057	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.15658	-118.48382	Commercial TI for a barber shop.  Title 24 plan check only for lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27732	15041-20000-06228	3460 W 7TH ST 1-168	90005	10	132B193   313	5093025028	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Info Complete	06/02/2015 12:00:00 AM	ADDRESS	34.05958	-118.3025	Title 24 plan check only.  Total area = 4,728 sq. ft.T.I. to existing commercial space.  Building is a highrise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27733	18041-20000-15691	8900 N ETON AVE Unit G	91304	3	195B105    99	2779017040	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.23192	-118.59494	Plan check for Title 24 only. Project site is a unit in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 672 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27734	17041-10000-22194	11869 S TEALE ST	90230	11	105B165   394	4220006065	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	33.98458	-118.4024	FULL PC FOR POWER AND ENERGY. TENANT IMPROVEMENT AND ADDITION WITHIN EXISTING 3 STORY OFFICE BUILDING. SCOPE INCLUDES NEW PANELS, NEW RECEPTACLES, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 41658 SQ. B#16014-10000-05276	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27735	11041-10001-13068	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	PIN	34.12750533	-118.21285206	REVISIONS TO PERMITTED SET OF PLANS-RE-ROUTED OUTPUT CONDUCTORS OF THE MV TRANSFORMER THROUGH AN EXISTING MANHOLE AND THEN ON TO THE AIR SWITCH AND MAIN SWITCHBOARD. INVERTERS ON ELECTRICAL PAD WERE REARRANGED TO ACCOMODATE NEW ROUTING OF CONDUCTORSNEW 1,124 KW PV SYSTEM.  PANELS ARE STAND ALONE IN THE PARKING LOT OF OCCIDENTAL COLLEGE.  PLAN CHECK IS FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27736	15041-10000-11703	1016 S TOWNE AVE #114	90021	14	124-5A211 349	5132009***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.03362	-118.24986	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27737	17041-10001-08467	1420 W 27TH ST	90007	8	123B197  1342	5054032003	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Apartment			03/16/2017 12:00:00 AM			PC Approved	06/30/2017 12:00:00 AM	ADDRESS	34.03029	-118.29223	EXPEDITE PER APPLICANT REQUEST. ((((((PV2. NEW SOLAR SYSTEM FOR AN EXISTING APARTMENT BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 16.0KWdc / 17.92KWac.(64)MODULES-LDK-280P-24 (32)MICROINVERTERS-APSYSTEM YC 500I	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27738	19041-10000-21925	1850 W SLAUSON AVE	90047	8	108B193  1513	6001001018	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	33.98887	-118.30986	Energy plan check for a (E) starbucks T.I. located in a single story building. Scope inlcudes new lighting and equipment with a total lighting area of 1472-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27739	11041-10000-05751	8316 W 3RD ST	90048	5	138B173   892	5511031036	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM			PC Approved	03/29/2011 12:00:00 AM	ADDRESS	34.0726	-118.37065	T.I.  EXISTING RESTAURANT.  MODIFYING EXTERIOR LIGHTING FOR PATIO AREA.  TITEL 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27740	15041-10000-11027	633 W 5TH ST 26TH & 28T-H FLS	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN OFFICES ON THE 28TH & 26TH FLOORPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27741	17041-10001-06393	3100 W RIVERSIDE DR	90027	4	153A205   140	5434017029	C2-1D-RIO	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM			PC Approved	05/10/2018 12:00:00 AM	ADDRESS	34.11252	-118.268	Changes to an approved set of plans. Changes include revising the single line diagram and lighting floor plans. Changes to reflect as built.Note: Permit Fees are paid under PCIS#17041-10000-06393	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27742	14041-20000-17359	300 S GRAND AVE 21st floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for energy only. New lighting (incl. emergency) on 21st floor of high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27743	12041-10000-11205	635 W DOWNEY WAY	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.01874	-118.28387	Re-route of conductors in duct bank.  4000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27744	12041-20000-06627	2121 S AVENUE OF THE STARS #140	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	T.I. to existing high rise building on the 1st floor.  Install new branch circuits and  general/emergency lighting.   Total new added connected load approximately 38A.   Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27745	18041-10000-28260	1161 N AVALON BLVD	90744	15	033B205   587	7420021024	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.7865	-118.26317	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27746	14041-20000-28098	13022 W GLAMIS ST	91331	7	204B161   210	2623010009	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.25681	-118.41652	PV1.  Install 5.75 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27747	13041-20000-33456	7100 N VAN NUYS BLVD #109	91405	6	183B149   161	2217007052	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.19938	-118.44856	Change to lighting in an existing office building.  All circuits are existing.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27748	11041-10000-22772	2111 N GRIFFIN AVE	90031	1	136-5A223  28	5204018006	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM			PC Approved	10/24/2011 12:00:00 AM	ADDRESS	34.06975	-118.21183	T.I. to an existing private school.  PLAN CHECK ONLY for Energy, no emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27749	17041-20000-09076	12700 W VAN NUYS BLVD bldg 11,12-,13	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM			Reviewed by Supervisor	04/13/2017 12:00:00 AM	ADDRESS	34.27528	-118.4092	pv2 ~~ install roof mounted pv system (ACM) sized 33kwAC,  (66) inverters, (132) modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27750	16041-20000-08449	14755 W VENTURA BLVD	91403	4	166-5A149  15	2265001006	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.15211	-118.4549	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,226 sq. ft.Note: Building permit has been pulled under 16016-10000-04236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27751	18041-10000-14731	1076 W 30TH ST	90007	9	121-5A201 140	5039019046	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			04/23/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.02731	-118.28605	PC FOR NEW FA SYSTEM IN COMM. 2 STORY BUILDING WITH BASEMENT. TOTAL DEVICE COUNT 62 WITH 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27752	16041-10000-44853	15817 W COMMUNITY ST	91343	12	192B141   322	2673015119	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.22309	-118.47709	PLAN CHECK FOR PV1 SFD ROOF MOUNTED SYSEM. TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM WITH 28 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27753	17041-20003-39882	10727 W WILSHIRE BLVD 1-109	90024	5	132B153   123	4360033***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Issued	04/15/2019 12:00:00 AM	ADDRESS	34.06081	-118.43692	04-15-2019 Revision to approved set of plans.  Change of (E) service voltage class to 480Y/277V.  Addition of 225 kVA transformer and associated disconnects.(((Plan check for power only.  Installation of new distribution board for installation of new car chargers in existing highrise residential building.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27754	12041-10000-28140	978 S GRAMERCY PL	90019	10	129B193   155	5081032008	R3-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.05327	-118.31307	ROOF MOUNTED PV1 SOLAR INSTALLATION. 36 MICROINVERTERS ON A STANDARD PLAN. PANEL UPGRADE INCLUDED IN FINAL FEE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27755	15041-10000-06912	6116 N RHODES AVE	91606	2	177B165   440	2333014031	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.18186	-118.40289	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (18) modules and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27756	16041-20000-21463	13120 W NIMROD PL	90049	11	129B137   331	4407011003	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	08/23/2021 12:00:00 AM	ADDRESS	34.05083	-118.49593	Plan check for SFD service 600A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27757	12041-10000-22790	3183 W WILSHIRE BLVD 1-449	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM			Reviewed by Supervisor	10/09/2012 12:00:00 AM	ADDRESS	34.06196	-118.29111	T.I. to existing building (Fresh and Easy).  Install new 600A panels, branch ciruits. and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27758	17041-20003-23238	9430 N TOPANGA CANYON BLVD #101,104-200,203	91311	12	198B101   335	2746013041	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	34.24159	-118.60598	Revisions to approved set of plans.  Change of lighting plan to include dimming switches and occupancy sensors.  (((ti to an existing commercial building two story.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 4415)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27759	16041-20000-37078	12203 W MOORPARK ST	91604	2	165B165   349	2364003046	[Q]R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			10/19/2016 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	34.15056	-118.39892	Plan check for power and energy. Project site is a new 3-story, 16-unit apartment building. Work includes a new 1,200-amp service and associated distribution equipment. Total lighting area is 15,410 sq. ft.Note: Building application has been generated under 16010-30000-01740	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27760	14041-10000-22081	4719 N CALHOUN AVE	91423	4	168B153   478	2248028013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.15663	-118.44231	Installation of roof mounted solar PV system.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27761	14041-20000-21658	1601-1603 W WILSHIRE BLVD	90017	1	132A205   392	5142009035	C2-2, C4-2, R4P-2, R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.05562	-118.27024	upgrade service to an existing commercial building from 800A to 1600A with three new panels.  All branch circuits are to be future.  energy plan check for hardscape area 420sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27762	18041-30000-35574	350 S FULLER AVE T36	90036	4	135B181   198	5509005006	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/20/2022 12:00:00 AM	ADDRESS	34.06835	-118.35086	Plan check for Power only on Existing High-Rise Building. Service upgrade to 4000A 120/208V, 3Ph, 4W. Existing emergency generator to connect to (E) ATS and new emergency panels. Install new distribution boards. Replace new panls inside every units. All existing load remain the same. Project is on methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27763	15041-10000-34682	10109 N PARR AVE	91040	7	204B193  1273	2560031008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM			Reviewed by Supervisor	10/26/2015 12:00:00 AM	ADDRESS	34.25283	-118.3133	PV1.  Installation of 11.925 kW DC roof-mounted, utility-interactive PV system.   (2) ABB PVI-6000-OUTD-US inverters with (45) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27764	14041-20001-12019	12650 W SANDHILL LANE Unit 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	33.9774	-118.4142	Fee for expedite only.*****Roof mounted PV system with system size 1.38KW.  Using transformerless inverters.  This part of a series set of submittal.  This PV system to interconnect to common service.  This is project 3 of 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27765	18041-20000-10395	120 N ROBERTSON BLVD SUITE L	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.07585	-118.38356	ti to an existing commercial building. adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27766	13041-10002-33879	2970 W OLYMPIC BLVD	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM			Corrections Issued	05/09/2014 12:00:00 AM	ADDRESS	34.05241	-118.29951	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.Changes to approved set of plans: module layout and manufacturer changed. number of modules remains the same.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27767	17041-10000-06301	1524 S ESSEX ST	90021	14	121-5A211 187	5132023034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.02743	-118.24916	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  38400 SQ FT. ( OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27768	14041-20000-04777	2250 E ALCAZAR ST room 270-271	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.06307	-118.2	"t24 part 6 energy for 300 sq office space. scope of work < 400A.note: permit fee precalculated under ""inspection"" fee period. The items were per engineer"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27769	15041-20000-28966	11680 W VICTORY BLVD	91606	2	180B169  1212	2335027002	C1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			Reviewed by Supervisor	10/02/2015 12:00:00 AM	ADDRESS	34.18651	-118.38718	Plan check for power only. Project site is an existing commercial space. Project scope is a service upgrade to 600 amps, (2) new panels and associated loads.Note: Title 24 was checked and approved under application number 15041-20000-15811Note: Building permit was filed under application number 14014-20000/20001-02602. Scope of work was change of use from (E) service station to (N) mini-mart.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27770	14041-10000-33382	1360 S FIGUEROA ST	90015	14	126A205    86	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM			Reviewed by Supervisor	12/11/2014 12:00:00 AM	ADDRESS	34.03896	-118.26891	Full plan check for first time tenant. (The address will be change to 1340  S Figueroa St)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27771	10041-10000-02157	4810 W SUNSET BLVD	90027	13	147B197   737	5543017018	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM	02/08/2010 12:00:00 AM		Permit Finaled	03/11/2010 12:00:00 AM	ADDRESS	34.09792	-118.29436	4 story bldg , church. 2 panels and 1 device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27772	17041-10000-22760	1925 S CENTURY PARK EAST STE 950	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.06066	-118.41426	T.I. OF OFFICE BUILDING, 9TH FLOOR, 2430 SQFT. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27773	11041-10000-10051	550 S MAPLETON DR	90024	5	138B157    56	4359013028	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2011 12:00:00 AM			PC Info Complete	10/11/2011 12:00:00 AM	ADDRESS	34.07442	-118.42882	NEW HOUSE 2 STORY OVER BASEMENT 19172 SF  *** 1 OF 2 ***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27774	11041-20000-08548	17401 W VENTURA BLVD #A-7	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			PC Info Complete	04/28/2011 12:00:00 AM	ADDRESS	34.16136	-118.51189	T.I. to existing building.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27775	12041-10000-06078	15630 W VENTURA BLVD	91436	5	168B141   685	2283006001	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Closed	09/26/2012 12:00:00 AM	ADDRESS	34.15484	-118.47446	TI in Fresh and Easy store, service was approved and permitted under seperate plan check, this plan check for new panels, circuits and T24.  FA under separate plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27776	15041-20000-28720	4346 N MATILIJA AVE 1-22	91423	4	165B153   396	2271017028	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.14985	-118.43389	PV2 COMMERCIAL ROOFTOP SOLAR. PC FOR PV SYSTEM INTERCONNECT TO HOUSE PANEL ON EXISTING APARTMENT BUILDING. PC FOR 66 MODULES, 2 CENTRAL INVERTERS. TOTAL OF 15.6KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27777	14041-20002-15486	4319 N LA BARCA DR	91356	3	165B117   247	2177005041	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	34.149	-118.55141	(($0 submittal fee due to senate bill 1222 from 2012))PV1.  Install 15.045 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27778	13041-10001-32334	5448 W HOLLYWOOD BLVD	90027	13	148-5A193 151	5544021910	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	04/12/2019 12:00:00 AM		Issued	04/12/2019 12:00:00 AM	ADDRESS	34.10157	-118.30874	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES REVISONS TO SPACE LAYOUT AND REDESIGN OF ELECTRICAL SYSTEM.  INCLUDING NEW METER AND PANEL  AND ADDITIONAL CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27779	13041-10000-32759	1500 W PACIFIC COAST HWY BLDG L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING L THIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27780	14041-20000-25782	1840 S CENTURY PARK EAST 5th floor	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Expired	11/07/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI to 5th floor corridors and elevator lobby.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27781	13041-10000-12081	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	(T)[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.09787	-118.31961	Plan check power and energy for Emerson Cafe located on the ground floor. Supply from building 3000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27782	11041-10000-11641	1545 W WILSHIRE BLVD 5th fl	90017	1	132A205   208	5142027025	CW	Central	Westlake			2091.02	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.05543	-118.26977	new panelboards and 60KVA UPS and circuits in renovating offices on the 5th flplan check is for title24 and 1 ea emergency ckt ; permit fee is in Inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27783	10041-10000-20882	1643 E 103RD ST	90002	15	091-5A213 142	6048013053	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM			PC Info Complete	10/20/2010 12:00:00 AM	ADDRESS	33.9448	-118.24489	TI IN AN EXISTING RETAIL STORE.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27784	17041-10000-23044	18016 W HARTLAND ST	91335	3	183B125   944	2122012011	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.19464	-118.5259	PC new rooftop solar for 12 new C26K-290 modules, 12 optimizers and 1 solaredge central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27785	19041-10000-07069	7540 WORLD WAY F/A-COSCO	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	33.94052	-118.42863	Fire Alarm system at LAX DELTA Maintenance Hanger.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27786	16041-10001-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	04/13/2017 Changes to the approved set of plan.  changes is under delta 6. Reloacation some of the existing lights, adding new llight fixtures and branch circuits. Change 1,600 amp service to two 800 amp services.  Removing some existing loads and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27787	13041-10000-10506	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			PC Approved	04/23/2013 12:00:00 AM	ADDRESS	34.05199	-118.25764	T24 energy plan check for TI to valet area in highrise parking A-level.  Lighting and outlet receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27788	13041-10002-35881	431 W 7TH ST 5th floor-6th floor	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM			PC Approved	04/06/2015 12:00:00 AM	ADDRESS	34.04654	-118.25516	Modifications to approved set based on architectural revisions.  Additional feeders to whirlpool panels by others.  (((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT for Los Angeles Athletic Club. 5TH AND 6TH FLOOR. HISTORIC. TENANT IMPROVEMENT ON 5TH AND 6TH FLOOR OF 7 STORY HEALTH CLUB : NEW. LOCKERS, RESTROOMS, SHOWERS, SPA. & INSTALL  2 (N) STAIRCASE CONNECTING 5TH & 6TH FLOOR &  ADD. NEW RESTAURANT & BARBER SHOP & RETAIL STORE  TO (E) 6TH FLOOR.ALL overcurrent protective devices shall be series rating for 72kaic. Specification sheets to be provided to inspector in the field.BUILDING PC # 13016-10000-26283)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27789	19041-20000-32219	20225 W LONDELIUS ST	91306	3	195B113   430	2781033009	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.22919	-118.57425	PLAN CHECK FOR INSTALLATION OF ENERGY STORAGE SYSTEM TO EXISTING SFD WITH EXISTING PV. SCOPE OF WORK CONSISTS OF (2) BATTERIES AND (3) PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27790	13041-10000-18852	505 S VIRGIL AVE	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.0649	-118.28724	TENANT IMPROVEMET ON A HEALTH CARE FACILITY ( MEDICAL OFFICE). 4 STORIES. 2 NEW PANELS, 1 NEW X RAY MACHINE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27791	11041-10000-23645	1000 N WESTERN AVE	90732	15	021B193   140	7445010041	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	33.75242	-118.30869	Lighting change in an existing Bank.  PLAN CHECK ONLY for Energy, per applicant Emergency lighting is on a seperate approved plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27792	17041-20001-43969	17550 W EMBASSY DR	91316	5	171B129   318	2257008047	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.16329	-118.51589	Expedited plan check fee. PV1.  Install 21.125 kW roof mounted grid tied PV system.  (65) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27793	11041-10000-13661	609 S WESTMORELAND AVE	90005	10	135B197  1052	5077009002	C1-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	34.06326	-118.2886	"Converting a 2 story house in to office spaces.  First time tenant / change of use.  Plan check is for energy and power.    ""COMPLY WITH DEPARTMENT ORDER effective date 07/05/2010. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27794	16041-10000-39610	2644 E ROSEVIEW AVE	90065	1	145-5A217  90	5453003054	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			11/08/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Issued	12/30/2016 12:00:00 AM	ADDRESS	34.09342	-118.22769	PV2 6kw roof mounted system with (1) inverter and (32) modules interconnecting through the load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27795	13041-10000-23253	225 S GRAND AVE	90012	14	132A211    60	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			Verifications in Progress	12/04/2013 12:00:00 AM	ADDRESS	34.05388	-118.25078	PLAN CHECK FOR FIRE ALARM IN A NEW HIGH-RISE BUILDING CONSISTING OF PULL STATIONS & SMOKE DETECTORS THROUGH OUT THE COMMON AREAS; FULLY-SPRINKLED SYSTEM FOR 20 FLOORS ( EXCLUDING 13TH FLOOR). 4 STORY PARKING UNDERNEATH THE BUILDING. NOTE: DURING PERMIT PROCESS , PLEASE VERIFY/DESIGNATE THE OWNER OF THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27796	14041-10000-17319	2708 E CESAR E CHAVEZ AVE 101-302	90033	14	127-5A225  74	5180017002	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.04477	-118.2039	"fire alarm system for 3 story VB . no automatic fire sprinklers. A2-b1 occupancy first floor and a2 occupancy second floor. b1-r3 third floor.NO: 94259  -- Building/Electrical/MechanicalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 01/18/2011 by Inspector JOHN STEPHENS atphone# (213)252-3051.  CEIS Case Number is 404180.Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.(Created: IMSV7 / 01-12-11)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 94260  -- Building/Electrical/MechanicalCode Enforcement Bureau has issued an order. This parcel iseligible for issuance of a 30 day time limit permit (includingBuilding, Electrical, HVAC and Plumbing) with a work descriptionas follows. ""COMPLY WITH DEPARTMENT ORDER effective date01/18/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27797	19041-10000-47153	1031 N LARKER AVE	90042	14	157-5A235 109	5716030042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.12524	-118.17074	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.56KWdc / 6.96KWac .(24)MODULES-Q_CELL Q.PEAK DUO-G5(24)ENPHASE I7PLUS-72-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27798	17041-20000-02967	15260 W VENTURA BLVD Ste 1730	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27799	15041-10000-29132	100 WORLD WAY SPACE 160	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR ENERGY. T.I. TERMINAL 1 OF LAX. EXISTING RETAIL STORE. TOTAL AREA 745 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27800	13041-10001-04191	6607 W 88TH ST	90045	11	096B165   907	4122019013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	33.95731	-118.40485	(((changes to approved set of plans : REC 245 PE. to REC 250 PE. using OLD fees PER APPLICANT REQUEST))) PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. TOTAL SYSTEM SIZE 2.16KW. USING MICROINVERTER ENPHASE M215-60-2LL-S22. USING 10 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27801	19041-20000-10205	13280 N DRONFIELD AVE #22	91342	7	225B153   311	2504018005	RD3-1-K	North Valley	Sylmar	Sylmar		1064.04	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.31289	-118.44322	pv1install roof mounted pv system sized 4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27802	15041-10000-08087	1635 W CARSON ST	90501	15	051B193   901	7349033025	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	33.83164	-118.30768	SERVICE UPGRADE TO 600 AMPS.  PLAN CHECK FOR POWER ONLY. ALL PANELS AND LOADS ARE EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27803	17041-20003-14335	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	"04/16/2018 Changes to an approved set of plans. All changes have been clouded. Sizing of feeders and OCPDs onto which System D is connecting to has been reduced to reflect existing field conditions.02/20/2018 Changes to an approved set of plans. Changes have been made to reflect field installation. Point of interconnection for all systems has been revised. Systems ""B"" and ""H"" have been combined. Location of inverters has changed. *****Previous Work Description*****EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar carports on roof of existing parking structure (Northridge Fashion Center). 825.9kW ungrounded system. (1992) 365W pv modules. Every two modules are connected to a 730W power optimizer."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27804	19041-10000-29024	431 N LA CIENEGA BLVD	90048	5	141B173  1259	4337009016	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Apartment			09/11/2019 12:00:00 AM			Reviewed by Supervisor	09/25/2019 12:00:00 AM	ADDRESS	34.07939	-118.37676	PLAN CHECK FOR 5-STORY 73 APARTMENT UNITS SERVICE SIZE OF 2500 A 3PH, 208/120 V. SCOPE OF WORK INCLUDES LIGHTING AND EQUIPMENTS. TOTAL AFFECTED AREA IS 107217 SQ.FTPERFORMANCE METHOD USEDPRECUT CHECK. TOTAL SQ.FT CHANGED TO 107,217 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27805	18041-10002-21259	3029 S 11TH AVE	90018	10	120B185   598	5051033022	R2-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Expired	10/19/2023 12:00:00 AM	ADDRESS	34.02673	-118.32943	Adding t1o modules to initial design, total modules now is 13, inverter size remain the same.<<Installation of roof-mounted solar 3.4 (DC) KW, PV system, with 11 PV modules on a single family dwelling.Permit was issued under 18041-90000-21259>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27806	17041-20001-09073	12700 W VAN NUYS BLVD Bldg 8	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	Revision to approved set of plans.  Delta 4 revisions only.  Addition of 100A main to (N) 200A house panel. (((Plan check for a PV2 roof-mounted PV system. System size is 6 kWac and consist of (1) inverter and (25) modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27807	18041-20000-06575	17959 W CANTARA ST	91335	12	192B129   533	2101018002	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.21941	-118.52498	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISINTING OF (18) IQ6-60 MICROINVERTERS. SYSTEM SIZE = 3.5KVA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27808	16041-20000-04206	14434 W SHERMAN WAY	91405	6	183B149    66	2217007053	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.20103	-118.44763	PLANCHECK FOR POWER AND ENERGY. CHANGE OF OCCUPANCY  FROM TRADE SCHOOL TO MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27809	15041-10001-21992	10979 W BLUFFSIDE DR	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	"CHANGES TO AN APPROVED SET OF PLANS, PC FOR POWER ONLY120/240 3p 4w, CHANGES INCLUDE THE ADDITION OF PANELS AND CIRCUITS UNDER DELTA 13. . ""ORIGINAL PERMIT CONSIST OF REMODELING OF A MIXED USED APARTMENT BUILDING. "" GENERATOR SET SHOWN ON E6.0 WILL BE SUBMITTED UNDER A SEPERATE PERMIT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27810	13041-10000-11188	111 E UNIVERSAL HOLLYWOOD DR 1ST & 2ND-FLOORS	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVEMENT IN CORRIDORS ON YHE 1ST FL AND CORRIDORS AND OFFICES  ON THE 2ND FL OF A HIGH RISE BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27811	17041-20002-39712	11335 N HERRICK AVE	91331	7	210B157    40	2534005025	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.2761	-118.42036	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27812	14041-10000-26820	9 E DUDLEY AVE	90291	11	109-5A141 122	4286030012	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	33.99418	-118.47975	Energy plan check for a store T.I  commercial building including indoor and outdoor. Total are is 1620 SQ feet. Plan check is based on 2008 standard due to building plan submited before July 1st.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27813	10041-20000-22479	10821 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	08/25/2011 12:00:00 AM	ADDRESS	34.26672	-118.52366	NEW SPROUTS FARMERS MARKET IN BUILDING D.  PLAN CHECK IS FOR POWER AND ENERGY.  POWER SUPPLYING SPROUTS APPROVED UNDER #11041-20000-03357. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27814	19041-10000-07324	8740 S SEPULVEDA BLVD	90045	11	096B165   900	4123002005	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	01/19/2022 12:00:00 AM	ADDRESS	33.95762	-118.39595	Energy plan check for a retail tenant improvement. Scope includes new lighting and equipment with a total area of 2,567 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27815	18041-30000-34621	1437 S ARMACOST AVE 1-18	90025	11	126B145   338	4263031016	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.04288	-118.46135	Install new Fire Alarm system on a New 18 unit 3-story over garage basement apartment.(1) FACP, (106) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27816	17041-20000-07855	7925 N MAESTRO AVE	91304	12	189B093   339	2020004002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.21445	-118.63983	pv1install roof mounted pv system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27817	14041-20001-08537	7021 N DE SOTO AVE	91303	3	183B109   937	2138027026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.19813	-118.58871	PV1 5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {PVI-5000-OUTD-US, SOLAREDGE SE5000A-US}]. [(20)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W}]     'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27818	15041-10000-33266	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	33.93845	-118.42964	PC FOR MED. VOLTAGE, 4160V. PROVIDING ONE 4000A AND ONE 1200A PANELS, ONE TRANSFORMER FOR NEW HANGOUT FOR QANTAS AIRLINE. METHANE LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27819	12041-10000-18546	13273 W VAN NUYS BLVD BLDG C	91331	7	207B157   342	2619017030	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.26587	-118.4227	"BUILDING ""C"".  RESTORATION OF BUILDING TO SUBDIVIDE INTO 3 SMALLER BUILDINGS SEPARATED WITH WALKWAYS; INTERIOR & EXTERIOR  REMODEL.  CHANGE OF USE FROM RETAIL TO RESTAURANT FOR PORTION OF THE BUILDING.   FULL PLAN CHECK FOR SHELL ONLY IN A METHANE ZONE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27820	14041-20000-28913	21631 W HEATHERLEE LANE	91311	12	210B105    70	2722004023	RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.27088	-118.60112	PV1 SFD. TOTAL SYSTEM SIZE 7.6KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING STANDARD PLAN. SYSTEM USES POWEFR OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27821	19041-20000-52843	10325 W TABOR ST 1-42	90034	5	120B161   651	4314014002	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	07/07/2022 12:00:00 AM	PIN	34.02519429	-118.40712707	Plan check for new Fire alarm system, new fire alarm devices: 143 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27822	19041-20000-00762	7809 W TORREYSON DR	90046	4	159B173   613	5570015012	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/02/2019 12:00:00 AM	ADDRESS	34.12877	-118.3696	PV1.  Install 17.16 kW roof mounted grid tied PV system with 13.2 kWh energy storage system.  (52) modules with microinverters.Permit fees $13.92 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27823	14041-10000-09792	350 S GRAND AVE SUITE ##-3325	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	PIN	34.05160512	-118.25169569	T24  ONLY FOR COMMERCIAL OFFICE BUILDING. TOTAL AREA 2167 SQ FT.,  tHIS IS HIGH RISE  WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27824	13041-20001-34593	3624 N GLENRIDGE DR	91423	4	162B157   979	2272028010	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.13617	-118.43264	EXPEDITE FEES ONLY<<<New rooftop PV system for an existing sfd.  System is UNGROUNDED.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27825	16041-10000-22202	1435 N CORONADO ST	90026	13	142-5A207 324	5424019014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.08372	-118.26631	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.48KWdc / 3.36KWac.(14)ENPHASE M250-60-LL-2-US(14)MODULES-LG320N1C	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27826	15041-20000-01780	17472 W GOLDEN LANE	91344	12	219B129   564	2608032022	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.29438	-118.51626	PV1. ROOFMOUNTED SOLAR SYSTEM. 9.6KW DC. MICROINVERTERS.(40)  SOLARWORLDS SW 275(40) ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27827	19041-10000-15362	250 W CENTER WAY PS-2b	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Issued	01/10/2020 12:00:00 AM	ADDRESS	33.94439	-118.40399	(LAX, ASSIGN TO FRANCIS PER APPLICANT REQUEST) PLAN CHECK FOR POWER AND ENERGY FOR TI TO P2B PARKING STRUCTURE AT LAX. SCOPE INCLUDES REPLACEMENT OF ALL LIGHTS, INSTALLATION OF ELECTRICAL VEHICLE CHARGING STATION,  NEW EM LIGHTING AND EQUIPMENT. SCOPE ALSO INCLUDES A 600A 480/277 SWITCHBOARD AND A 75KVA TRANSFORMER. TOTAL AFFECTED AREA IS 299,500 SQ.FT	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
27828	14041-20002-20207	9221 N ARLETA AVE	91331	6	198B157   732	2625010002	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.23746	-118.42148	11/02/2015 Changes to an approved set of plans. The rating of the (9) string inverters has gone from 11.4 kWac to 12.0 kWac each. System size is now 108 kWac.*****Previous Work Description*****EXPEDITE FEESPV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 102.6KW AC. USING 9 CENTRAL INVERTERS. WITH 468 DC MODULES. CONNECT TO 208 3 PHASE LOAD SIDE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27829	19041-10000-43180	1148 S STEARNS DR	90035	5	132B173  1072	5087020022	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/16/2019 12:00:00 AM	ADDRESS	34.055	-118.36967	[Eplan] New roof top installation with system size of 7.50KW DC/7.6kWAC, USING Central inverter(SE7600H-US), 25 MODULES (Silfab SLA-M 300), 25 OPTIMIZERS (P320), WITH A EXISTING SERVICE SIZE 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27830	14041-20002-35577	706-720 N CAHUENGA BLVD	90038	13	141B185   537	5533032014	C4-1XL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.08371	-118.32861	[[[2/3/16  CHANGES TO APPROVED SET. ADDITION OF INV1A AND INV2A  INVERTERS.]]]11/17/15  changes to approve set. all changes made under delta 8. Scope includes adding site lighting. (((TI TO AN EXISTING COMMERCIAL 2 STORY BUILDING.  ADDING CIRCUITS TO EXISTINF PANELS, NEW LIGHTING AND CONTROLS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 27248.FEES ARE ESTIMATED PLAN CHECKER TO VERIFY.  CORE AND SHELL RENOVATION OF EXISTING STORE W/AXILLARY OFFICE, MANUFACTURING AND STORAGE TO OFFICE USE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27831	18041-20000-44904	18155 W PARTHENIA ST	91325	12	195B125   800	2769019036	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	PIN	34.22908883	-118.52906755	PV3.  Install 10.36 kW roof mounted grid tied PV system.  (28) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27832	17041-10001-16942	1120 N CITRUS AVE	90038	4	144B185   643	5532019019	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Info Complete	07/27/2017 12:00:00 AM	ADDRESS	34.09137	-118.33969	Supplemental PC for T24 only for office TI. Load iunder 400A.PC for new lights with total sqft 8730.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27833	15041-10000-01532	3412 S KEESHEN DR	90066	11	117B153   976	4248020021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.01417	-118.43609	install roof mounted solar array, interconnect with main panel. system size: 5.1 kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27834	18041-10001-05548	420 S WESTLAKE AVE	90057	1	133-5A205 204	5154026016	R4-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.06005	-118.2727	EXPEDITE PER APPLICANT REQUEST. ROOF MOUNTED PV ON COMMERCIAL ROOF. SYSTEM SIZE 87KWAC/85.44 KWDCSCOPE INCLUDES 244 MODULES WITH 4 CENTRAL INVERTERS, TRANSFORMER AND NEW PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27835	19041-20002-40600	15564 W OTSEGO ST	91436	5	171B141   282	2261032019	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.16308	-118.47408	10/31/19CHANGES TO APPROVED SET CHANGES TO BUSBAR RATING.<<<PLAN CHECK FOR A NEW PV SYSTEM USING  AC MODULES. TOTAL SYSTEM SIZE IS  3.6KWAC / 4KWDC________________________________________________________________Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27836	18041-20000-43758	20837 W SPRUCE CIR #63	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.29535	-118.58815	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27837	13041-10000-04784	5055 W WILSHIRE BLVD #600	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.06235	-118.34036	PC POWER AND ENERGY. TI OFFICE->OFFICE. replace 1200A SWBD, 300 kva xfmr, and office TI. 6TH FLOOR HIRISE. no raised floor for server room. UPS is 100 KVA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27838	18041-10000-13325	11111 W SANTA MONICA BLVD 6th FL	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTROOMS.  (6th floor)BUILDING PERMIT # 18016-10000-10230	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27839	14041-20000-14544	18747 W WELLS DR	91356	3	171B121   411	2161012012	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			Plans on Hold	06/05/2014 12:00:00 AM	ADDRESS	34.16329	-118.54081	pv1 single family. total system size 11kw ac using 2 central invertes. nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27840	19041-10001-23931			8	088-5A203 205	6074014034	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	PIN	33.93626329	-118.27701287	"DELTA ""1"" Changes to approved plans for using the existing 100Amp Service equipment instead of ugrading to 200Amp. ((((PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 10 MODULES (CANADIAN SOLAR 305), OPTIMIZERS (SEP320) AND A CENTRAL INVERTER (SE3000H-US). SYSTEM SIZE IS 3.05KWdc AND 3KWac))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27841	16041-10001-10942	9403 S BANDERA ST	90002	15	094-5A215 284	6048033029	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM			PC Approved	04/07/2016 12:00:00 AM	ADDRESS	33.95142	-118.23976	PC FOR A NEW PV SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(10)MODULES-KYOCERA #KD255GX-LFB3(1)INVERTER-PVI-3.0-OUTD-S-US-Z-ANOTE: PERMIT PAID UNDER PCIS#16041-90000-10942((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27842	17041-20000-19624	18133 W VENTURA BLVD ste 300	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.16603	-118.52861	build out to the third floor of an existing medical building.  adding new lighting and new controls to new panels.  plan check for power and energy. building application number: 17016-20000-45725	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27843	17041-10000-35322	2511 S COMPTON AVE	90011	9	117A213   124	5118010002	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.0157	-118.24698	1-story addition to warehousePLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27844	18041-20001-46593	5316 N OVERING DR	91367	3	171B089   168	2047018014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2018 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.16686	-118.64736	Expedite per appliant requestPlan check for PV roof mounted system, system size: 17.92kW  DC, 13.6kW AC with 56 PV modules and 2 inverters(6.0kW and 7.6kW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27845	13041-20000-32114	12105 W BLUFF CREEK DR	90094	11	105B165   936	4211010103	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	33.97901	-118.40436	PLAN CHECK FOR POWER AND ENERGY FOR TI OF EXISTING OFFICE BUILDING. SCOPE OF WORK ON THE FIRST AND SECOND FLOOR. T24 SQRFT 33120	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27846	18041-30000-09174	8811 W 3RD ST	90048	5	138B169   540	4334001021	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Public Safety Only			03/13/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.07372	-118.38414	Plan check for Title 24 only in existing space retail T.I. replace lighting and receptacles.  Total area: 3680 sq ft.B#18016-30000-04276	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27847	15041-10001-31188	9840 N MELVIN AVE	91324	12	201B117   152	2761033019	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM			Verifications in Progress	11/13/2015 12:00:00 AM	ADDRESS	34.24926	-118.56002	INSTALLATION OF 12.6KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27848	16041-10000-07430	9346 N GLENOAKS BLVD	91352	6	198B173    53	2538011009	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			PC Info Complete	03/02/2016 12:00:00 AM	ADDRESS	34.23862	-118.37542	(TI to Fire damaged repair) Install new lightings. PC for T-24 only. Total area: 7,255 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27849	11041-10000-06035	333 S GRAND AVE suite#2600	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	03/29/2011 12:00:00 AM	ADDRESS	34.05271	-118.25179	Ti in an existing office. EPC is for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27850	13041-20000-24202	11500 W OLYMPIC BLVD Suite 623	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.03624	-118.44415	T24 FOR EXISTING LAB. NOT PART OF HIGHRISE. DOING LIGHTING AND RECEPTACLES ONLY. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27851	16041-20001-29380	7858 W DENIVELLE ROAD	91040	7	210B193   241	2552013012	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	34.27226	-118.30459	RSES expedited plan check fee per applicant request. PV1.  Install 15.2 kW roof mounted utility interactive PV system.  (55) modules with (2) SolarEdge 7600 W inverters with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27852	16041-20000-01157	232 E 2ND ST 1-240	90012	14	129A213    28	5161024034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Closed	11/14/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	Plan check for power and temporary service. 800A temporary power pole.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27853	19041-10000-38635	7102 N TUJUNGA AVE	91605	2	183B173   138	2319001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.19975	-118.37887	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27854	19041-10000-44487	2424 E OLYMPIC BLVD	90021	14	121-5A217 390	5168002800	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.02545	-118.22917	"REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY ""BLDG 3"" (OUTDOOR)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27855	16041-10000-02408	1274 N BENEDICT CANYON DR	90210	5	144B157   218	4356028009	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Expired	02/23/2018 12:00:00 AM	ADDRESS	34.09197	-118.42751	PV1 installation of a roof mouted system interconnected with the main panel. (1) inverter rating: 6 kw, (20) Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27856	14041-20000-04240	2022 S LOUELLA AVE	90291	11	111B149   593	4242016018	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.00085	-118.45154	pc for pv1 single family dwelling. inverter has isolation transformer. using 3 strings for single inverter. total system size 5kw ac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27857	19041-10000-22219	6033 W CENTURY BLVD 1ST FLOOR	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.94572	-118.38954	PC FOR Interior TI FOR  fist floor lobby of (E) office building. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1125 SQ.FT. B#19016-10000-09796	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27858	16041-20000-15139	10447 N GLORY AVE	91042	7	204B201   117	2565001057	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.25888	-118.28112	PV1.  Install 5.5 kW DC roof-mounted PV system.  (20) 270W modules with 6000W rated central inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27859	14041-20000-10316	4965 N MEDINA DR	91364	3	168B105   325	2171014093	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			Corrections Issued	04/18/2014 12:00:00 AM	ADDRESS	34.15839	-118.60241	PV1.  Install 6.5 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27860	19041-20000-27671	3505 N EAGLE ROCK BLVD	90065	1	154-5A215 262	5457026011	[Q]CM-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	10/28/2021 12:00:00 AM		Permit Finaled	02/10/2023 12:00:00 AM	ADDRESS	34.1161	-118.23588	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27861	13041-10000-15888	1901 1/2 S BUNDY DR	90025	11	123B149   379	4259019012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.03435	-118.45789	CONSTRUCTION OF NEW 850 SF RESTROOM FACILITY WITH SHOWERS AND CHANGING ROOMSAND SALES CANOPYplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27862	11041-20001-16139	14401 W SATICOY ST	91405	6	186B149     7	2215001910	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	10/20/2011 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.20855	-118.4479	Supplemental plan check for revision to approved plans. New roof mounted 106.59KW Photovoltaic system LADWP telecomm warehouse building. Permit for the installation under this application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27863	10041-20001-13603	6090 W PICO BLVD	90035	10	129B173   256	5068002001	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			04/13/2011 12:00:00 AM			PC Approved	04/13/2011 12:00:00 AM	ADDRESS	34.05263	-118.37368	REVISION TO 10041-20000-13603.  CHANGING INDOOR LIGHTING FIXTURES.  REDUCING THE AMOUNT OF WATTAGE USED.  TITLE 24 PLAN CHECK ONLY.  (PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE/OCCUPANCY  FROM RETAIL TO SYNAGOGUE (PLACE ASSEMBLY).  EXISTING 400A SERVICE.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27864	16041-10000-26234	4520 N VAN NUYS BLVD	91403	4	168A151   188	2265013025	C2-1VL-RIO, P-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.15371	-118.4485	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (HUMPHREY YOGART). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 317 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27865	14041-20000-03669	1211 N LAS PALMAS AVE	90038	4	144B185  1339	5532004032	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.09304	-118.33648	PV1, roof-mounted solar installation, to interconnect with (E) 200A main service. system sized @ 1.59 kW DC, with (6) modules (suniva #opt265-4-1b0) , (1) power-one #auorora pvi-3000-outd-s-us inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27866	19041-20000-53246	6300 N VARIEL AVE 1-256	91367	3	177B105   130	2149003042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	08/21/2020 12:00:00 AM	ADDRESS	34.18443	-118.59259	ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27867	13041-10000-28675	939 S HILL ST	90015	14	127-5A209 229	5139004008	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/18/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.04215	-118.25823	Temporary power and distribution equipment (600A service) for construction.  Panels are provide as part of the drawing but will not be installed till structure is up.  Pnls will be mounted on framed structures and will be moved out once permanat power in place.  Methane zone level 2, seal off is provide by contrcator as extra measure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27868	17041-10000-08416	15805 W ROSCOE BLVD	91343	12	192B141   467	2673016064	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.22154	-118.47701	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 14,400 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27869	10041-20000-19240	345 S OXFORD AVE 1-12	90020	4	135B193   371	5503003021	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.01	Electrical	Electrical	Public Safety Only			09/28/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	02/09/2011 12:00:00 AM	ADDRESS	34.06761	-118.30804	Plan check for fire alarm panel replacement. 1 smoke detector added to existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27870	10041-20000-25894	442-446 N LA BREA AVE	90036	5	141B181  1305	5525029005	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	02/07/2011 12:00:00 AM		Permit Finaled	03/15/2012 12:00:00 AM	ADDRESS	34.07956	-118.34385	energy plan check book store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27871	16041-20000-21501	16830-16924 W SAN FERNANDO MISSION BLVD	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Closed	09/02/2020 12:00:00 AM	ADDRESS	34.27181	-118.49871	PLANCHECK FOR POWER AND ENERGY. SERVICE UPGRADE AND TENANT IMPROVEMENT FIR URGENT CARE MEDICAL CLINIC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27872	18041-30000-13386	4425 N CANOGA AVE	91364	3	166-5A107 173	2190014022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Issued	04/12/2018 12:00:00 AM	ADDRESS	34.14993	-118.5957	Plan check for the addition of (3) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27873	16041-20000-10816	4544 N SAUGUS AVE	91403	4	166-5A145  37	2276008015	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.15234	-118.46602	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EL POLLO LOCO.  1452 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27874	19041-10000-15213	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	34.04337	-118.23442	PLAN CHECK FOR TITLE 24 ONLY CHANGE OF USE FROM RETAIL TO OFFICE CORE AND SHELL OFFICE BUILDING. TOTAL EFFECTED AREA 15593 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27875	17041-10000-23326	11401 N PORTER RANCH DR BLDG 7	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	03/01/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 15 unit apartment with 1,200 amp 208 volt service.       Building 7 of 10.  Type II.       Building permit #17010-10000-02384	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27876	14041-20000-17590	13076 W RELIANCE ST	91331	6	195B161   313	2627018010	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.23317	-118.4178	PV1.  Install 3.924 kW roof-moutned, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27877	15041-20000-41764	221 N FIGUEROA ST 16th Floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.05882	-118.25099	TI on (E) office space. All electrical equipment are existing. PC for Energy only. Total area: 17, 464	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27878	13041-10001-01477	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM			PC Approved	09/09/2013 12:00:00 AM	ADDRESS	34.03393	-118.22985	Revisions to permitted set of plans: change the outlay of the bar to a rectangular shape; removed freight elevator ; reduced lighting density; rearrange circuits(((((((First time tenant for a restaurant space.  Power and energy.PLACE OF ASSEMBLY. OCCUPANT LOAD: 220+	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27879	16041-20000-00882	17024 W MAYALL ST	91325	12	204B133   486	2694010021	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Expired	02/08/2018 12:00:00 AM	ADDRESS	34.25379	-118.50359	PV1.  Install 5 kW roof-mounted utility-interactive PV system.  (22) Kyocera KU2656ZPA modules with ABB PVI-5000-OUTD-US.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27880	14041-10000-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			09/15/2014 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	33.95637	-118.3838	New building construction.  61 unit 4 story apartment building with new 3kA electrical service.  63,272 sq. ft. of common area included on title 24 forms.*3/24/16: Extension filed. Last date to obtain the permit is on 9/15/16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27881	09041-20001-15121	2920 S SEPULVEDA BLVD	90064	5	120B157   137	4251003012	C2-1VL, R4P-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.02823	-118.42906	PLAN CHECK FOR REVISION TO APPROVED PLANS. REVISION CONSIST OF NEW LOADS ADDED TO PANELS, FLOOR PLANS, AND T24 ENERGY CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27882	11041-10000-09466	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.09815	-118.32564	NEW FIRE ALARM FOR EXISTING HIGH RISE BUILDING.  22 STORY HIGH.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27883	14041-10001-07463	4321 N MATILIJA AVE	91423	4	165B153   415	2271016***	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			03/20/2014 12:00:00 AM			PC Approved	08/12/2014 12:00:00 AM	ADDRESS	34.14936	-118.43417	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM ON UNIT 18 OF CONDOMINIUMS, NON STANDARD MICROINVERTER PLANS. SYSTEM SIZE: 3.71 KW.(14) SOLARWORLD 265W(14) ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27884	17041-20000-39157	8900 N DE SOTO AVE B-102	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.23162	-118.58832	Replacement of (7) existing recessed panels for facilities maintenance on second floor of building 102.  Plan check for power per applicant request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27885	14041-20001-26767	23339 W KESWICK ST	91304	12	186B093    40	2027001014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.20966	-118.63712	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECTED MSP.(52) KYOCERA KD255 MODULES(52) POWER OPTIMIZERS(2) SOLAR EDGE INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27886	10041-10000-18846	1269 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/27/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.0518	-118.2253	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27887	11041-20000-04571	127 S SAN VICENTE BLVD Bulletin-44TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	advanced health sciences pavillion  TI level 2 plaza  bulletin # 44	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27888	18041-10000-45562	380 WORLD WAY TBiT-T-34	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	FULL PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT OF 1,812SQFT  FOOD & BEVERAGE CONCESSION  - TOTAL NEW CONNECTED LOAD IS APPROX. 400A TO EXISTING 480/277V SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27889	15041-20000-13178	20321 W AETNA ST	91367	3	177B113   145	2149008010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.17902	-118.57625	$0 permit fee due to senate bill 1222 from 2012Plan check for PV roof top mounted system 12.6kWac with 65  modules(Kyocera ku2606xpa) and 3 inverters(PV13.6 outd and PVI 500 OUTD and PVI 3.6 OUTD) connected to 225 main panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27890	15041-20000-06337	9131 N INDEPENDENCE AVE	91311	12	198B109   170	2746009045	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.23623	-118.59094	Plan check for power. Project scope is the installation of (6) new panels, manufacturing equipment, and bus duct distribution (326 ft).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27891	16041-10000-44896	350 S GRAND AVE	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	TI TO VALET OFFICE AREA AND ELEVATOR LOBBIES. LOBBY TYPICAL FOR P1-P6. UPDATEED LIGHTING. PROVIDED NEW T24. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27892	16041-10001-07076	11265 N ESKO AVE	91342	7	210B181    50	2550020023	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM			PC Approved	04/22/2016 12:00:00 AM	ADDRESS	34.2746	-118.34765	"Expedited rses plan check per applicant request.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11KW INTERCONNECTED WITH MSP.(38) SUNPOWER SPR327NE-WHT MODULES(2) POWERONE PVI-6000/5000 INVERTERSThis plan was already approve under 15041-10000-32218, they""ve lost the approved set."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27893	14041-10000-16989	737-741 S BROADWAY	90014	14	127-5A209  77	5144014030	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.04443	-118.25434	"Title 24 plan check only.  Total area = 7,745 sq. ft.TI to existing retail space ""the GAP"" including lighting, panels, and outlets."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27894	16041-10000-33241	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE/DATA ROOM/STORAGE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5889 SQ. FT. b#16016-10000-22298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27895	17041-10001-43472	5175 N AVENIDA ORIENTE	91356	3	171B125   405	2161023013	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.16538	-118.5318	PV1 10.8KW AC roof mounted system with (30) AC modules interconnecting through the  subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27896	17041-10000-32653	360 E 2ND ST #150-#150A	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Info Complete	09/13/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC for T24 only for Yoga suite TI. PC for new lights. Installing new lights, circuits, and receptacles. Total area 2053sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27897	16041-10000-44344	12919 S FIGUEROA ST	90248	15	081B201   311	6132003023	M2-1VL-O, P-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	33.91455	-118.28296	PC FOR POWER AND ENERGY. T.I .  CONVERT WAREHOUSE TO OFFICE.  POWER REVISION AND T24 ENERGY. 400A SERVICE, 37305 SQ FT.B# 16014-10000-05897	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27898	16041-20001-19879	2121 S AVENUE OF THE STARS LOBBY	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check for energy per inspector's corrections notice.  LOBBY LIGHTING RETROFIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27899	19041-20001-07149	5536 N LINDLEY AVE 1-129	91316	5	174B125   454	2159005021	R3-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.17161	-118.52708	Expedited plan check fee.PV2.  Install 99.00 kW DC / 88.85 kW AC roof mounted grid tied PV system.  (275) modules with (3) 30 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27900	15041-10000-34836	5670 W WILSHIRE BLVD 25TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.06222	-118.35208	T-24, TI TO THE 25TH FLOOR OF AN (E) HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES WITH EXISTING PANELS. TOTAL SQ. FT. 12854.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27901	19041-10000-16201	6700 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.19196	-118.6056	FULL PLAN CHECK POWER AND T-24 TO AN EXISTING TARGET STORE. SCOPE INCLUDE ADDING NEW CKTS TO AN EXISING PANELS AND CHANGING LIGHT FIXTURES.  SCOPE OF WORK AREA 136,736SF. Emergency lighting is not part of the scope.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27902	16041-20000-40262	1635 N FORMOSA AVE	90046	4	147B181   282	5548009021	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.1008	-118.34688	"""0$ permit fees due to senate bill 1222""Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 30.4kW (5kW*3+7.7kW*2) ungrounded system. (118) 340W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27903	15041-10001-05842	4605 W DON MIGUEL DR	90008	8	114B177   417	5028019024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM			Reviewed by Supervisor	03/09/2015 12:00:00 AM	ADDRESS	34.00531	-118.35657	PV1.  Install 13 kW roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27904	16041-10000-43919	11133 S AVIATION BLVD	90045	11	087B173    99	4129037908	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	33.93246	-118.37734	PC FOR 3000A NEW SERVICE FOR FUTURE SPECIAL EQUIPMENT UNDER SEPARATE PERMITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27905	12041-10000-07209	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT  (STARBUCKS) TO A MIXED USED  BUILDING, PLAN CHECK #10041-20000-15146.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27906	19041-20000-21962	1901 S AVENUE OF THE STARS STE 1060	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM			PC Info Complete	06/10/2019 12:00:00 AM	ADDRESS	34.05949	-118.41705	PLAN CHECK FOR T24 TI TO EXISTING HIGH RISE OFFICE BUILDING SUITE 1060. LIGHTS AND OUTLETS ONLY, TOTAL SQUARE FOOTAGE = 2,310 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27907	11041-20001-12570	18440 W ROSCOE BLVD	91335	12	192B125   936	2102001020	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM			PC Approved	10/25/2012 12:00:00 AM	PIN	34.21978104	-118.53506889	Changes to previously approved set of plans. Plan check for energy and emergency lighting. Relocation of IDF (computer equipment) room. Single story stand alone building. Mental health clinic (mostly offices and conference rooms, no exam rooms). 2906 sqft. T.I. to existing building of outpatient therapy.  Install general/emergency lighting.  Plan check for energy only. and low voltage data permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27908	18041-20000-36326	18000 W DEVONSHIRE ST	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.25698	-118.52508	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 669,549 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27909	16041-10001-45228	10250 W SANTA MONICA BLVD # 1995	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"This is Plan check only, revision noted under delta-b on the single line diagram (1) to add information of the landlords dist board and to change the 200A fuse to a 200A MCB,  (2) add fault current values.<<Full PC for 1st time Tenant ""Papyrus"" Ste. 1995.  Install new wiring, and  panels, total area 904 sq.ft>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27910	17041-20000-22659	11114 N BORDEN AVE	91331	7	210B165   379	2532030011	RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.2719	-118.4038	PV1.  Install 6.84 kW DC roof mounted grid tied PV system.  (19) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27911	10041-10000-05913	350 S GRAND AVE 39th Floor	90013	9	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	05/21/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check T-24 Energy (general/emergency) lighting on TI work the 39th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27912	15041-20000-07849	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.12774	-118.26247	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COSTCO OPTOMETRY ROOMS. NOT A MEDICAL ( CONSULTATION ONLY) 615 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27913	15041-20001-38389	11821 W GWYNNE LANE	90077	5	153B141   106	4378037078	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM			PC Approved	03/18/2016 12:00:00 AM	ADDRESS	34.11581	-118.47468	Expedited per customer request.PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel.(44) SOLARWORLD SW285 Modules(2) SMA America SB6000 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27914	14041-20001-34474	2254 S WELLESLEY AVE	90064	11	123B149   927	4259030013	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	34.03002	-118.45362	CHANGES TO APPROVED SET OF PLANS. RELOCATION OF EQUIPMENT. MODULES AND ELECTRICAL CONNECTIONS REMAIN. RESTAMP NEW SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27915	14041-10000-12546	15760 W VENTURA BLVD 1100	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.1552	-118.47684	T.I. EXPANSION OF 2,148 S.F.  NEW WALL, NEW DOORS & BUILD (N) NON-BEARING PARTITION WALLS.(5/12/14) Permit to be pulled at electrical plan check counter only.  Plan check for energy only.  Less than 400 amps per applicant (high rise).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27916	19041-20002-31263	23341 W LOS ENCINOS WAY	91367	3	171B093   322	2044018010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.16596	-118.6357	"Delta ""B"" changes to approved plans for connecting the 80Amp, PV breaker after the main 175Amp CB. Plan Check Only. Permit was issued under 19041-20001-31263<<<PV1.  Install 16.38 kW roof mounted grid tied PV system.  (52) modules with (2) 7.6 kW rated inverters.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27917	17041-20002-28910	10964 W VENTURA BLVD	91604	2	162B173   572	2378007012	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1438.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.14	-118.3695	[[[10/26/2017 CHANGES TO APPROVED SET. DELTA 2 CHANGES ARE CLOUDED. CHANGES TO LIGHTING AND CONTROLS  ]]]09/14/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for energy only. TI - change of use from retail to restaurant. New lighting (incl. emergency) - 1,088sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27918	18041-20000-16578	13445 N GLENOAKS BLVD	91342	7	225B145    79	2501021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.31638	-118.4614	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,527 sq. ft.Note: Building permit has been issued under 18016-20000-07397	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27919	19041-20000-31289	515 N BUNDY DR	90049	11	135B141   137	4402031006	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.06895	-118.47657	Plan check for PV roof mounted system, System size: 6.5KW DC, 5.806KW AC with 20 PV Modules and 10 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27920	18041-10001-47200	1186 E MONTECITO DR	90031	1	144A227   482	5304010018	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.08765	-118.19961	0$ DUE TO AB1414 / SB122.SUPPLEMENTAL PERMIT TO APPROVED SET(PC DONE UNDER 18041-10000-47200) PV1, INSTALLING 8.165 KWDC SYSTEM WITH (23) MODULES , (2) AC INVERTER WITH 7.6 KW, (1) 3 KW,  (1) POWER OPTIMIZER P400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27921	14041-20000-32680	7317 N RESEDA BLVD	91335	3	186B125   819	2118015009	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Issued	11/24/2014 12:00:00 AM	ADDRESS	34.20355	-118.53632	pv1central inverter standard plan system size 5kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27922	13041-10000-31927	5600 W SUNSET BLVD	90028	13	147A193   109	5544029032	[Q]C2-2D	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.09792	-118.3112	PLAN CHECK FOR POWER ONLY. REPLACING 85KW BACKUP  DIESEL GENERATOR WITH NEW 350KW GENERATOR. ADDITION OF 3 ATS AND 37 CKTS. HOME DEPOT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27923	13041-20000-18118	9301 N TAMPA AVE SPACE 86	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI FOR BEAUTY SALON. NOT A FIRST TIME TENANT, THE LOAD IS NOT CHANGING. 688 SQRFT.  BEAUTY SALON LOCATION ON SPACE 86. ONLY USING 4 FIXTURE F3's	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27924	14041-10000-23569	16836 W BOSQUE DR	91436	5	165B133   247	2291003005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Expired	11/02/2016 12:00:00 AM	ADDRESS	34.14957	-118.49954	PV1, INSTALL 22.34 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(88) MODULES: KYOCERA  KD255GX-LFB3(3) SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27925	17041-10001-02219	8323 N BALBOA BLVD	91325	12	192B133   235	2690023190	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.22177	-118.50286	02/17/2017 Changes to an approved set of plan. Changes include lighting fixture to existing and add occupancy sensor in each walk in cooler. Changes has been clouded area only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27926	17041-10000-45150	5006 W FRANKLIN AVE	90027	4	150B197   896	5589034014	RD1.5-1XL	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.10525	-118.29869	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 4.93 KWACSCOPE INCLUDES 17 MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27927	16041-10000-04433	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.01318	-118.34004	PC for a new fire alarm system to a New 4-story Kaiser Permanente Medical Office Building. Scope includes 487 FA devices, 1 FA panel, and 1 Comm. panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27928	14041-10001-01618	926 N SERRANO AVE	90029	13	144B193  1313	5535024028	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			Reviewed by Supervisor	01/28/2014 12:00:00 AM	ADDRESS	34.08704	-118.30626	Expedited RSES plan check per applicant request.{{PV1, Install 2.00 kW DC roof-mounted solar array for a two-story home, interconnect with existing panel.(1) Transformerless inverter: Power-One  AURORA  PVI-3.0-OUTD-S-US.(6) Modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27929	09041-10002-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans for the north  and south concourses at TBIT -Revisions are noted in  bulletins GDN-009  On the plans, each change is clouded and noted to the reference GDN-009.CONDUCTORS FOR THE ev CHARGING STATION WILL NOT BE PUT IN PLACE.. FOR EACH CONCOURSE, POWER WILL BE FROM A NEW SUB PANEL AND FROM A RELOCATED 800A DISTRIBUITION BOARD.DRAWINGS SHOW THAT CONDUIT WILL BE STUB UP AND WIRING DONE LATER. FOOTPRINT FOR THE CHARGING STATIONS WILL REMAIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27930	17041-10000-07462	636 E VENICE BLVD	90291	11	108B145  1741	4237002007	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	33.98944	-118.46126	TITLE 24 FOR EXISTING LOW RISE BUILDING. TI FOR EXISTING RESTAURANT TO NEW RESTAURANT. CONNECTED LOAD IS LESS THAN 400A. TOTAL AREA = 2385 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27931	19041-20001-06169	4441 N LA BARCA DR	91356	3	165B117    27	2177002018	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.15177	-118.55175	SUPPLEMENTAL FOR EXPEDITEPLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. TOTAL SYSTEM SIZE IS 11.4 KW AC, SCOPE OF WORK INCLUDES (35) CANADIAN CS3U-370 WITH P400 OPTIMIZERS, (1) SE11400A-US INVERTER, NO MAIN SERVICE PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27932	14041-20003-13377	20757 W KINGSBURY ST	91311	12	207B109   389	2706011031	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.26373	-118.58634	plan check only for adding additional pv disconnect and relocating (2) inverters, (2) meters, (1) disconnect and a load center. plan check fee is 0.00 due to senate bill 1222 from 2012.((( PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.5KW INTERCONNECTED WITH MAIN PANEL.(30) MODULES RENESOLA 250W WITH POWER OPTIMIZERS(2) TRANSFORMAERLESS INVERTERS SE3800A)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27933	19041-20000-03607	5007 N AMIGO AVE	91356	3	171B121   562	2176014024	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.16118	-118.53944	Plan check for a PV1 roof-mounted PV system. System size is 17.08 kWdc/15 kWac-CEC and consists of (2) inverters, (56) modules, (3) load center, and (3) battery back-up units.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27934	19041-10000-28086	2010 S SAWTELLE BLVD	90025	11	126B153   696	4261032054	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.04074	-118.44325	P.C FOR TITLE 24 TI FOR A TEA HOUSE CHANGE OF USE FROM BEAUTY SALON. TOTAL AFFECTED AREA 944 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27935	10041-10000-10652	100 N LA CIENEGA BLVD	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.07466	-118.37629	"CHANGE OF USE TO ""CHASE BANK"". PLAN CHECK IS FOR POWER & ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27936	14041-20000-08977	20481 W CELTIC ST	91311	12	210B109    58	2707030001	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.27142	-118.57945	New roof mounted PV system with Optimizer and transformerless inverters.  System size 12.75KW.$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27937	19041-10000-05101	361 S SPRING ST	90013	14	129A211    30	5149019034	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	08/31/2021 12:00:00 AM	ADDRESS	34.0492	-118.24814	FULL PC FOR POWER AND ENERGY FOR A NEW 12-STORY HOTEL BUILDING. SCOPE INCLUDES A NEW SERVICE 3,000A, 277/480V 3 PHASE SERVICE/DISTRIBUTION. TOTAL  AFFECTED AREA IS 45,040 SQ. FT. B#18010-10000-02402	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27938	14041-10000-04682	331 E 113TH ST	90061	8	087A205   186	6073026027	R2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	33.93213	-118.26828	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27939	16041-10000-26484	11232 W BRIARCLIFF LANE	91604	2	156B169   205	2381020015	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.12622	-118.3803	PLANCHECK FOR ADDITION OF TESLA POWER WALL TO AN EXISTING RESIDENTIAL ROOFTOP SYSTEM ( FIRST POWERWALL SYSTEM:  BRING BRINGS TO TAILGATE/ CONTACT BEHZAD  )	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27940	11041-10001-27025	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM			PC Approved	11/20/2012 12:00:00 AM	ADDRESS	34.04661	-118.2324	REVISED PERMITTED SET OF PLANS : BLDG A HAS UNIT SUBSTATION REPLACED WITH INVIDUAL   UNITS; BLDGS B, C AND D HAVE BUS DUCTS REPLACED WITH 5KV CABLES AND UNIT SUBSTATIONS RELOCATED TO FOURTH FLOOR AND REPLACED WITH INDIVIDUAL UNITS. (((((((((((PROPOSED 6-STORIES MIXED USE BUILDING: RETAIL;APTS;LIVE/WORK UNITS;OFFICES;GARAGE;PORTION OF THE BUILDING IS 5-STORIES, TYPE IIIA, APTS OVER 1-STORY TYPE I GARAGE/RETAIL/OFFICE.OTHER PORTION IS 3-STORIES TYPE IIIA APTS OVER 3-STORIES TYPE I	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27941	17041-10000-24730	2601 S FIGUEROA ST BLDG 2	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.02804	-118.2763	PC FOR FA SYSTEM SYSTEM. BUILDING 2. TOTAL OF 547 DEVICES AND 10 PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27942	18041-20000-49118	18578 W MARILLA ST	91324	12	201B121   429	2763033043	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.24702	-118.53898	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27943	14041-10000-18087	2455 N CREST VIEW DR	90046	4	153B169   246	5564015019	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Expired	08/19/2016 12:00:00 AM	ADDRESS	34.11637	-118.38996	Install roof mounted solar system on existing residential building.  Total system size = 6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27944	13041-20000-09134	13316 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	PIN	34.31253789	-118.42511113	Enphase system on roof of single family dwelling..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27945	17041-10003-42783	443 S SAN PEDRO ST	90013	14	127-5A213 105	5148011018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.04477	-118.24374	Change to an approved set by updating conditional/unconditional T24 floor plan and reflecting all livework and office spaces to the final building approval set. All changes under delta-1 only.BUILDING APP#17016-10000-32478	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27946	11041-10000-09081	751 N ECHO PARK AVE	90026	13	138A209    47	5404015900	OS-1XL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM			PC Approved	05/04/2011 12:00:00 AM	ADDRESS	34.07242	-118.25998	ALTERATIONS AT THE ECHO PARK BOATHOUSEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27947	18041-10000-38757	9007 N WOODMAN AVE	91331	6	195B153   291	2639033006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.23306	-118.43913	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27948	19041-10000-51553	610 S MAIN ST	90014	14	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.04479	-118.25017	ENERGY PLAN CHECK ONLY FOR 4 FLOORS IN A 7 FLOOR STORY BUILDING. WORK SCOPE INCLUDES CHANGING LIGHTS IN AND OCCUPANCY SENSORS IN STORAGE AREAS. AREA OF SCOPE 620sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27949	18041-10000-17357	19571 S MAGELLAN DR	90502	15	057B197    29	7351034080	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.85355	-118.29307	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27950	16041-20000-26729	700 S FLOWER ST #2100	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only in existing high-rise. Total area: 15, 554  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27951	16041-10000-37047	5700 N SEPULVEDA BLVD	91411	4	174B145   295	2243004010	(T)(Q)RAS4-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.17405	-118.46591	PLAN CHECK FOR FIRE ALAM SYSTEM FOR NEW MIXED USED  6-STORY, 131-UNIT APARTMENT BUILDING. TOTQAL OF 461 DEVICESB#14010-20000-01820E#15041-10000-37324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27952	19041-10000-11867	1040 N LAS PALMAS AVE STAGE 10	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27953	19041-20000-53393	166 S ALVARADO ST	90057	13	135A205   127	5154006010	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	07/16/2021 12:00:00 AM	ADDRESS	34.06484	-118.27127	INSTALL NEW (202) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27954	10041-10000-17307	4512 W JEFFERSON BLVD	90016	10	120B181   784	5046009008	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	03/30/2011 12:00:00 AM	ADDRESS	34.02539	-118.34544	Ti in an existing commercial building. Plan check for T24 and Emergency lights..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27955	19041-30000-07333	16661 W VENTURA BLVD #600	91436	5	168B137   270	2259011034	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.15837	-118.49645	Plan check for power and energy.  Project scope is a tenant improvement to an existing medical office (dental) in Suite #600.Note: Building application has been geNote:nerated under 18016-20000-24652	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27956	19041-10000-28768	3309 S LA CIENEGA PL	90016	10	120B173    73	4205034007	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.02871	-118.37528	NEW FIRE ALARM SYSTEM WITH 99 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27957	17041-10000-18401	888 S HOPE ST	90017	14	127-5A209  28	5144020196	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			06/05/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.0452	-118.25996	PC FOR NEW FA IN HIGH RISE 35 FLOOR TOTAL  DEVICE COUNT 1803 PANEL 13	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27958	16041-10000-34955	845 S FIGUEROA ST	90017	14	129A207   195	5144022900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.04698	-118.26234	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A SMART & FINAL. TOTAL AFFECTED AREA IS 186 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27959	14041-10003-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	EXPEDITE FEE PER APPLICANT REQUEST. FEES FOR THE REST OF ENERGY PLANC CHECK IS INCLUDED UNDER THIS APPLICATION.(((((((Changes to approved set.  New lighting fixtures used.  New lighting layout in parking garage levels A and B.  New euipment layout in electrical rooms.  New IT rooms and elevator.  Addition of elevator control rooms and security room.  Relocating connections to two switchboards (MS-ELB41 & MS-ELA42).  Tenant list has been revised with load calculations and feeder schedule updated accordingly.  Lighting and power floor plan seperated into two floor plans.   All changes are clouded with delta 19.This project is phase 3 of Westfield Century City which includes all underground areas and parking garage areas plus main service, switchgear, conduits, and distribution panels for tenants.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27960	18041-10000-47864	2801 1/2 S VINEYARD AVE	90016	10	123B181  1294	5057010013	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.0311	-118.34477	PC FOR A SOLAR PV (APATMENT BUILDING,COMMERCIAL). SYSTEM CONSIST OF 8 MODULES (Q.PEAK-G4.1/SC 295-305). 1 CENTRAL IVERTER (ABB UNO-DM-3.3-TL-PLUS-US).1-125A LOAD CENTER INTERCONNECTING THROUGH THE MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27961	16041-10000-39239	10509 W WASHINGTON BLVD	90232	5	117B165   249	4208008037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Info Complete	11/07/2016 12:00:00 AM	ADDRESS	34.01804	-118.4039	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A STORAGE SPACE. TOTAL AFFECTED AREAIS 780 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27962	14041-10000-03070	835 W 40TH PL	90037	9	114B197   280	5019001010	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Expired	03/15/2016 12:00:00 AM	ADDRESS	34.01017	-118.28849	PV1, Install 2.5 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U(15) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27963	10041-20001-10887	15840 W MONTE ST #B101	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	06/14/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.31015	-118.47604	PLAN CHECK T-24 ENERGY FOR GENERAL LIGHTING IN OFFICE AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27964	19041-20000-36921	5940 N LINDLEY AVE	91316	5	177B125   799	2159009002	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.17839	-118.52711	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 8.505 KW DC/7.6KW AC. ALSO A NEW 13.5 KWH BATTERY ENERGY STORAGE SYSTEM. SCOPE OF WORK CONSISTS OF (27) PV MODULES WITH OPTIMIZERS AND A 7.6KW INVERTER , (1) 13.5 KWH BATTERy, AND (1) SUB PANELS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27965	19041-10000-31715	2035 N WESTRIDGE ROAD	90049	11	138B133   418	4492011010	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.07238	-118.50083	(ePlan) PLAN CHECK FOR ESS(TESLA POWERWALL) CONNECTED TO EXISTING PV SYSTEMMAIN BREAKER DERATING SHALL BE PULLED UNDER SEPARATE PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27966	15041-10002-16207	7280 W MELROSE AVE	90036	5	141B181   623	5525013027	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	PIN	34.08325977	-118.34845856	12/09/2015CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 3. CHANGES INCLUDE THE ADDITION OF A 75KVA TRANSFORMER. ((9/22/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2 PER INSPECTOR REQUEST.    CHANGES INCLUDE AIC RATING FOR EQUIPMENT AND RATING OF PHASE CONVERTER.  THIS IS PLAN CHECK ONLY.TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  NEW 600 AMP SWITCHGEAR, NEW PANELS AND CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 3865.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27967	14041-20000-29502	2317 S COTNER AVE	90064	5	123B153    35	4322023036	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			PC Info Complete	10/23/2014 12:00:00 AM	ADDRESS	34.03727	-118.43782	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING LIGHTING INDOOR/OUTDOOR.  5539 SQFT.  USING EXISTING POWER EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27968	17041-20000-12533	16246 W TUBA ST	91343	12	204B137   439	2678023011	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.25639	-118.48656	PV1.  Install 6 kW roof mounted grid tied PV sytsem.  Central inverter standard plan.  SMA inverter with (19) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27969	19041-20000-18741	12131 N MISSION RIDGE WAY	91344	12	216B129    70	2608033013	RE15-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.29171	-118.51683	Paln check for PV roof mounted system, system size: 6.4kW , 7.6kW AC with 20 PV Modules and 1 inverter(7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27970	15041-10000-40498	19841 W NORDHOFF PL STE 119	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.23699	-118.5659	PC FOR NEW LIGHTING IN WAREHOUSE. LESS THAN 85% DENSITY. EXISTING CONTROLS OK. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27971	19041-10000-47915	2619 N FIGUEROA ST SUITE D	90065	1	142-5A219 129	5446010023	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	34.08438	-118.22201	T-24, ENERGY PLAN CHECK. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING SPACE. TOTAL AFFECTED AREA IS 2049 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27972	17041-20001-00686	20014 W HIAWATHA ST	91311	12	207B113   263	2708018005	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.26043	-118.56921	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (58) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27973	12041-10000-10415	3601 S TROUSDALE PKWY	90089	9	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM			PC Approved	05/16/2012 12:00:00 AM	ADDRESS	34.02017	-118.28558	USC STU 106 Remodel.  Load is 70.9A.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27974	10041-10000-23683	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		1390.00	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM	01/25/2011 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.18088	-118.48309	DISCONNECT THE EXISTING 4160V, 3PHASE FEEDERS TO THE EXISTING 2MVA TRANSFORMER (US-102) AND INSTALL NEW 750MCM FEEDERS TO CONNECT THE SAME TRANSFORMER TO A NEW LOCATION (BAY 2-9)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27975	16041-10000-17507	7817 N LANKERSHIM BLVD	91605	6	189B169   659	2310025031	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.21268	-118.388	PC FOR EMERGENCY EGRESS LIGHTING FOR AN EXISTING APARTMENT BUILDING. PC PER APPLICANT REQUEST. TOTAL AFFECTED AREA IS APPROX. 20,000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27976	18041-20000-09172	11671 W ERWIN ST	91606	2	177B169   333	2335032017	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Apartment			03/13/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	34.18318	-118.3868	Plan check for power and energy. Project site is a new 3-story, 10-unit apartment building. Work includes a 800-amp service and a total lighting area of 6,330 sq. ft.Note: Building application has been generated under 17010-30000-02813.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27977	14041-10000-04112	2916 W FRANCIS AVE	90005	1	132B197   658	5077024002	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.0567	-118.28969	PV1.  Install 5.886 kW DC roof-mounted PV system on rear garage (load center in interior storage room), interconnect with main service panel at main house.  18 modules: SunPower SPR-327NE-WHT-D.  Transformed inverter: SRP-5000m	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27978	12041-10000-29962	11111 W SANTA MONICA BLVD	90025	5	129B153   651	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM			PC Info Complete	01/18/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	FULL PLAN CHECK FOR ENERGY AND POWER. CHANGE OF USE FROM OFFICE TO COFFEE SHOP. PROJECT LOCATED IN A HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27979	16041-20000-12504	15301 W VENTURA BLVD Suite 450	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for energy only. TI to existing office on 4th floor of high rise office building. New lighting (incl. emergency) and receptacles. 4,010sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27980	14041-10001-12963	2215 N VERMONT AVE	90027	4	153B197   663	5588016044	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM			PC Approved	05/24/2014 12:00:00 AM	ADDRESS	34.11184	-118.29212	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 14.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTERS AND WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27981	10041-20001-25093	1121-1141 N AVALON BLVD	90744	15	033B205   754	7420021021	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	33.78539	-118.26305	Upgrade service to 800 amp for YMCA.  Install new switchboard, subpanels, branch circuits, and lighting.  Plan check for power and energy.  A variance for Fire Alarm submitted. ((this application is for recheck and restamp for extra set of approved plans. permit has already been issued under original application))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27982	13041-20000-26392	915 W WILSHIRE BLVD Suite 1050	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.05069	-118.2599	T24 FOR HIGHRISE OFFICE SPACE. SCOPE OF WORK ON UNIT 1050. TOTAL SQRFT 9080. TOTAL NEW CONNECTED LOAD IS 140AMPS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27983	16041-10000-08486	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	ALL EQUIPMENT ARE EXISTING;  MCP s are  removed from PDP-B12 and refed from PDP-A12; FEEDERS AND FEEDER  CIRCUIT BREAKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27984	14041-20000-01737	1 W WORLD WAY WEST TERMINAL 7	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	PIN	33.94461393	-118.39808495	T24 FOR NEW SIGNS. SCOPE OF WORK ON TERMINAL 7	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27985	12041-10000-20659	1513 1/2 N WILCOX AVE	90028	13	147A187   100	5547017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	PIN	34.09834029	-118.33119678	TENANT IMPROVEMENT IN SMALL RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27986	16041-20001-11634	1213 N DOUGLAS ST	90026	1	138A211    25	5405002004	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Apartment			04/04/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.07399	-118.25251	Expedited RSES plan check per applicant request.  PV2.  Install 5.2 kW roof mounted solar system on top of lowrise 3-unit apartment building.  (16) modules with a transformerless 5kW rated central inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27987	15041-10001-23543	6318 N CALLICOTT AVE	91367	3	177B093   131	2035016005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.18468	-118.6368	EXPEDITED RSES PLAN CHECK PER APPLICANT <<<PV 1 INSTALL A NEW 12925 KW DC ROOF MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME (48) MODULES REC SOLAR REC275TP  (1) INVERTER SOLAREDGE SE 11400A-US 240V>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27988	16041-20000-36269	3330 N CAHUENGA BLVD WEST 510	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.13099	-118.35061	Plan check for title 24 energy. Tenant improvement for offices slate digital suite 510 (2185sqft).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27989	18041-20000-29753	2018 S ROXBURY DR	90035	5	129B165   880	4307014030	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.04673	-118.40126	pv1install roof mounted pv system sized 20.3 KW AC interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
27990	15041-20000-31398	2619 E CESAR E CHAVEZ AVE	90033	14	129A225   391	5177033015	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.04557	-118.20454	TI. NEW MUSIC RECORDING ROOMS. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27991	19041-10000-15794	8608 S BROADWAY	90003	8	097-5A203 374	6040013014	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Issued	04/30/2019 12:00:00 AM	ADDRESS	33.95974	-118.27799	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTRES T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27992	17041-10000-02942	5744 S BRYNHURST AVE	90043	8	108B185   821	5006003016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	33.98954	-118.33317	Installation of roof-mounted solar PV system, a total AC output of 5kW, in a 1 or 2 family dwelling. Permit was pulled under online application 16041-90000-12402. PC and permit for the one module added.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
27993	15041-20000-18188	7713 N HASKELL AVE	91406	6	189B141   262	2206011035	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.21086	-118.47511	Installation of new roof mounted solar PV array on existing commercial building.  Total system size = 96 kWac.  Total of four inverters rated at 24 kWac each.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
27994	17041-10001-34094	3043 S CAVENDISH DR	90064	5	123B161   123	4316011014	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM			Verifications in Progress	10/17/2017 12:00:00 AM	ADDRESS	34.03657	-118.406	EXPEDITE PER  APPLICANT REQUEST.PC FOR ROOF MOUNTED PV ON SFD WITH POWERWALL BATTERY.TOTAL SYSTEM SIZE IS 3.0KWac/ 4.0 KWDC(10)MODULES WITH OPTIMIZERS (1)INVERTER-(1)200A SUBPANEL(1)TESLA AC POWERWALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27995	18041-20000-19491	978 S GRAMERCY PL	90019	4	129B193   155	5081032008	R3-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.05327	-118.31307	Plan check for the addition of a Tesla PowerWall onto an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27996	15041-10001-11235	939 S BROADWAY	90015	14	127-5A209 278	5139003006	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			09/02/2015 12:00:00 AM			PC Info Complete	09/04/2015 12:00:00 AM	ADDRESS	34.04157	-118.25708	Change to approved set by replacing a 15hp compressor with a 50hp elevator.(((Pc for power. Temporary poower for modifiction an apartment building, one 600A distribution board , two motors.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27997	14041-10000-17376	12542 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	33.97819	-118.41198	PC FOR METHANE MITIGATION. NEW Type VA  6-unit  4-story  APARTMENT BUILDING with attached parking. 1 PANEL, 27 DEVICES. BUILDING APP# 14010-10000-01296.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
27998	18041-10000-09358	350 S GRAND AVE 34th flr	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan Check for energy only, Men's & Women's Restroom upgrades at 34th floor of existing commercial building. Total sq. ft. 727.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
27999	13041-10000-04341	3183 W WILSHIRE BLVD	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.06196	-118.29111	PERMIT SHALL BE OBTAINED AT PLAN CHECK COUNTER.(( submittal 2 at time of corrections review since original plan did not contain completed T24 compliance sheet information for Vermont-side lobby - only Wilshire-side lobby was plan checked ))NOT A HIGH RISE PER APPLICANT.  TI FOR A MIXED-USE BUILDING.  T24 FOR LOBBY AND OFFICE LIGHTING.  2852 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28000	16041-20000-02001	17009 W RINALDI ST	91344	12	213B133   663	2607019036	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.27947	-118.5026	TI to existing commercial building (retail convenience store for a gas station). Adding new lighting including emergency. Total sqft. 1,114.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28001	16041-10000-15170	12077 W VENTURA PL	91604	2	165B165  1214	2368002013	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.14493	-118.39507	T24 - CHANGE OF USE TO A TAKE OUT RESTAURANT. SCOPE OF WORK INCLUDES NEW INDOOR AND OUTDOOR LIGHTING AND RECEPTECALS. TOTAL SQFT 650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28002	17041-10001-25778	921 S CATALINA ST	90006	10	132B197   967	5094023009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.05507	-118.29553	CHANGES TO APPROVED SET OF PLANSINCLUDING ADDITIONAL SUBPANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28003	13041-10000-21428	1245 W WILSHIRE BLVD 1ST FLOOR	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Finaled	10/28/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	RADIATION ONCOLOGY ON FIRST FLOOR OF HIGH RISE MEDICAL OFFICE BUILDING. PLAN CHECK POWER & ENERGY INCLUDING OSHPD 3 REQUIREMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28004	12041-10000-27139	15743 W SORBONNE ST	91342	7	225B141    26	2603019014	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.3173	-118.47477	ROOF MOUNTED PV1 SOLAR INSTALLATION 7.848KW. STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28005	14041-20001-01412	1734 S BARRY AVE 1-8	90025	11	126B149   648	4262019016	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM			Reviewed by Supervisor	01/31/2014 12:00:00 AM	ADDRESS	34.04122	-118.45223	(((EXPEDITE FEES)))PV2 APARTMENT COMMON METER. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28006	13041-20000-24872	15211 W COBALT ST	91342	7	225B145   236	2501010007	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.31284	-118.46364	PV1 TRANSFORMERLESS SYSTEM. 16 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 4.1 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28007	11041-10000-20552	10306 S WILMINGTON AVE 1-4	90002	15	091-5A215 181	6066001045	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	09/14/2012 12:00:00 AM	ADDRESS	33.94295	-118.23879	New core and shell for new retail shopping center, with new 800A service and 4 sub-panels.  Plan check is for Energy and Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28008	14041-20002-14174	20287 W VIA MEDICI	91326	12	219B113   151	2701043023	RE11-1-H, RS-1	North Valley	Chatsworth - Porter Ranch, Mission Hills - Panorama City - North Hills	North Hills West, Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Expired	08/11/2016 12:00:00 AM	ADDRESS	34.2946	-118.57589	Change from previously approved plans.  Reduce the number of modules to downsize from 7.8KW to 7.4KW. Note: Plan check fee and permit fee is $0.00 due to Senate Bill 1222 from 2012. *****Previous Description*****PV1Install roof-mounted solar array, interconnect with main panel. System size: 7.8kW(1) Power-One Aurora PVI-3.6-OUTD-S-US-Z-A transformerless inverter(1) Power-One Aurora PVI-4.2-OUTD-S-US-Z-A transformerless inverter(36) Trina Solar #TSM-255PA05.18 pv modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28009	18041-20000-00523	6601 S CENTER DR WEST 7th Floor	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	33.97997	-118.39375	Plan check for Title 24 only. Project site is the restrooms on the 7th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 465 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28010	17041-10000-43095	11869 N PHILLIPPI AVE	91331	7	216B161   540	2527003016	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.28568	-118.41558	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.40KWdc / 7.60KWac.(28)MODULES-HIS-S300RG MONO(28)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SE7600A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28011	19041-30000-21642	801 S FIGUEROA ST 20th Floor-Restrooms	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Issued	07/26/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the 20th floor restrooms of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 650 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28012	18041-20001-11034	1374 W 35TH ST	90007	8	120B197   735	5040004025	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.02449	-118.29977	07-03-2018 Changes to an approved set of plan. Changes include new lighting in room 206,207,208,209. All Changes has been clouded. new Total lighing area: 5,577 sq ft. ((((((Plan check for power and energy. Project site is an existing commercial building.  Change of use from middle school to elementary/tenant improvement. Total lighting area = 2,600 sq. ft.Note: Building application has been generated under 18016-10000-08891))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28013	14041-10000-11295	1537 N NORFOLK ST 2F	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.06138	-118.20223	Remodel pathology suite - plan check for  lighting & power. Total area = 10245 sq ft. BLDG#14016-10-06134.Plan check: 14041-10-11297 covers other half of 2nd floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28014	19041-10000-15788	6348 W FOOTHILL BLVD	91042	7	198B205   113	2572009018	(Q)C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1013.00	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.2423	-118.26963	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28015	17041-10000-25303	1441 E BOYD ST	90033	14	127-5A219 118	5172018014	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.04445	-118.22484	PC FOR PARKING GARAGE. UPGRADE LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28016	16041-10001-25486	407 N ARDMORE AVE	90004	13	138B193   162	5521023013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Apartment			09/07/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.07789	-118.30254	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. INSTALLATION OF FAN COIL AND ALTERNATIVE CONDENSER SIZE.  INCREASE IN FEEDER CONDUCTOR SIZE. PC FOR DELTA 2 ONLY. PERMIT FOR ADDED WORK TO BE ISSUED UNDER THIS APPLICATION. THIS APPLICATION IS ALSO TO CORRECT ENGINEER OF RECORD. PC ONLY. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28017	16041-20000-00376	221 N FIGUEROA ST 12th Floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for Titlt 24 only for T.I. Total area: 16,734 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28018	15041-20000-44046	5232 N ELVIRA ROAD	91364	3	171B105   738	2168019050	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Expired	02/01/2018 12:00:00 AM	ADDRESS	34.16382	-118.60256	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6 KW ungrounded. Using 300W power optimizers. (29) 275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28019	16041-20001-12908	640 N FRIES AVE	90744	15	030B205   667	7416034041	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	ADDRESS	33.77814	-118.2647	[[3/7/17 CHANGES TO APPROVED SET. T24 CHANGES ONLY. CHANGING FIXTURE B TO LED IN PROCESSING, STAGING AND FREEZER STORAGE]]]Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,887 sq. ft.Note: Building application has been created under 16016-20000-05066	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28020	13041-10000-06762	441 S BARRINGTON AVE 1-45	90049	11	132B145   113	4401010057	R3-1, RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			03/15/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.06009	-118.46885	NEW CONSTRUCTION OF 45 UNIT 4 STORY APARTMENT BUILDING WITH UNDERGROUND GARAGE. PC FOR POWER AND ENERGY. SITE LOCATED IN METHANE BUFFER ZONE LEVEL I. NO METHANE MITIGATION REQUIRED BASE ON METHANE REPORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28021	13041-20001-25245	202 N AVENUE 64	90042	14	154-5A233 385	5493016013	[Q]C4-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	11/25/2013 12:00:00 AM	ADDRESS	34.11564	-118.18062	((EXPEDITE FEES)0PV2 COMMERCIAL SYSTEM. ROOF MOUNTED. TOTAL SYSTEM SIZE 4.3 KW USING 20 MODULES. USING ENPHASE MICROINVERTER M215. 2 STRINGS. 200A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28022	18041-20000-28142	16056 W AIGLON ST	90272	11	126B121    89	4414004016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.04486	-118.538	Plan check for a PV1 roof-mounted PV system. System size is 12.54 kWdc/11.53 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (38) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28023	13041-10000-21157	517 N SAN PASCUAL AVE	90042	14	154-5A235 247	5716028017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.04	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM			PC Info Complete	08/07/2013 12:00:00 AM	ADDRESS	34.11686	-118.17448	PV modification to already approved plan.  Module rating chnages from 245 W to 250 W.  Everything else is the sa,me permit is existing this plan check only	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28024	17041-10000-06700	12234 W SHERMAN WAY	91605	2	183B165    79	2321001018	[Q]M1-1VL, [Q]P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.20057	-118.39993	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR) TOTAL AREA  73850 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28025	17041-10000-26793	1111 S GRAND AVE	90015	14	127-5A207 332	5139021***	RD1.5-1XL, [Q]R5-4D-O	Central	Central City, San Pedro	Central San Pedro, Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.04144	-118.26266	Power plan check for a new panel connectiong to an existing serving for new EV load for an existing high rise building.  Scope includes new 600A panel, (4) transformer and (8) panels with no load on it.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28026	14041-20000-17028	590 S BURLINGAME AVE	90049	11	129B141     1	4264008001	A1-1XL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.04606	-118.48522	T.I. to an existing country club building on the entire 2nd floor and kitchen on 1st floor.  Install new panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28027	18041-10000-24366	5831 N NORWICH AVE	91411	4	174B145    87	2243016019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.17674	-118.46091	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 3.00KWdc / 2.80KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER AND A METER ADAPTER. (10)MODULES-SOLARWORLD  SW-300(10)OPTIMIZERS-ENPHASE S280--60-LL-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28028	13041-20000-03490	8422 N WHITE OAK AVE	91325	12	192B129   189	2787014005	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.22371	-118.51937	Enphase system on roof of single family dwellling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28029	15041-20000-18401	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	33.9427	-118.40223	Plan check for energy regulation receptacle and RTI given per applicant request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28030	14041-20000-25358	17260 W RAYEN ST	91325	12	195B133   211	2690013012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.23207	-118.5107	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.( 50) TRINA SOLAR TSM-250 MODULES(2) ABB PVI-5000 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28031	19041-20000-46102	5820 N CANOGA AVE 1st Floor	91367	3	174B105    78	2149019009	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.17555	-118.59717	Power and lighting for (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28032	13041-10000-04199	2700 S FIGUEROA ST # 105	90007	9	121-5A203  98	5123018033	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM			PC Approved	02/19/2013 12:00:00 AM	ADDRESS	34.02708	-118.27647	renovation of existing juice barplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28033	14041-10000-15252	12555 W JEFFERSON BLVD SUITE 100	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	33.97954	-118.41361	Title 24 placn check only.  Total area = 6592 sq. ftReplace lighting for existing low rise commercial space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28034	13041-20000-16707	56 E WINDWARD AVE	90291	11	106-5A143  40	4226009014	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	33.98728	-118.47263	PC FOR T24 ENERGY ONLY. TOTAL AREA 365 SQ FT. NEW LIGHTING. PERMIT TO BE ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28035	16041-10000-33462	18164 W ARMINTA ST	91335	12	189B125   549	2102017114	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.21373	-118.52954	Plan check for PV roof mounted system. System size: 9.16kW with 28 AC modules 3 source circuits connected to load center.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28036	18041-20000-05893	862 N MORAGA DR	90049	5	141B145   445	4368015003	[Q]R3-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Apartment			02/16/2018 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	08/10/2022 12:00:00 AM	ADDRESS	34.07916	-118.46803	1000A 208Y/120V 3PH-4W SERVICE, DISTRIBUTION, POWER AND LIGHTING FOR NEW BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28037	15041-20000-41237	111 S AVENUE 59	90042	1	151-5A229 148	5492015010	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.11012	-118.19059	TI and chnage of use from Office to Retail.  MS upgraded to 600A. PC for Power and Energy. Total area: 3,514 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28038	14041-10000-18331	2728 S MALCOLM AVE	90064	5	123B157   314	4255017019	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.03529	-118.42208	Install roof mounted solar pannels with a single inverter ungrounded system.  Total size = 6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28039	19041-10000-50143	11401 N PORTER RANCH DR	91326	12	213B113   481	2701100004	C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			12/05/2019 12:00:00 AM	06/24/2020 12:00:00 AM		Permit Finaled	02/03/2022 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for PV solar system. System size 178KW. (400) modules, (3) inverters,PERMIT FEE IS  $0 IN ACCORDANDANCE WITH AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28040	10041-10000-19188	770 W WILSHIRE BLVD 7TH FL	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.04914	-118.25811	TENANT IMPROVEMENTS IN THE ELEVATOR LOBBY AND REST ROOMS AND ADDING WIRED OFFICE  FURNITURE USING EXISTING BRANCH CIRCUITSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28041	18041-10000-42117	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			Reviewed by Supervisor	11/16/2018 12:00:00 AM	PIN	33.94094587	-118.40577128	"INSTALLING 3 NEW OPTIONAL BACKUP GENERATORS AT 800KW, 800KW & 350KW FOR THE NEW ""MSC"" TERMINAL AT LAX. (Per MZ)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28042	17041-30000-24631	23921 W KILLION ST	91367	3	171B089    37	2047011021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Issued	07/20/2017 12:00:00 AM	ADDRESS	34.16842	-118.64882	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (1) load center, and (32) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28043	13041-20000-17908	4643 W VANTAGE AVE	91607	2	168B165   778	2356036027	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	PIN	34.15531123	-118.3979661	pv1 single family dwelling using transformerless inverter with POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28044	17041-10000-07759	10100 W SANTA MONICA BLVD STE 975	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for Title 24 for office T.I. high-rise building lighing and receptacle. 9th floor Suite 975 Total area: 2,679 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28045	15041-20000-40272	12867 N CAPE COTTAGE LANE	91342	7	222B157   387	2525025072	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.30388	-118.41941	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (25) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28046	12041-20000-21822	4144 S GLENCOE AVE A-B	90292	11	108B153  1207	4230006008	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	33.98891	-118.44171	PLAN CHECK POWER AND ENEGY FOR TENANT IMPROVEMENT OF AN EXISTING OFFICE BUILDING.  BUILDINGS A & B	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28047	17041-10000-29873	7926 S VERMONT AVE	90044	8	099B197   617	6032001019	[Q]C2-1	South Los Angeles	South Los Angeles			2383.10	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	33.96698	-118.29132	COIN LAUNDRY PC FOR POWER AND ENERGY. ALL NEW SERVICE AND BUILD OUT.B#16014-10000-06219	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28048	10041-10000-17766	6862 N HAYVENHURST AVE	91406	6	183B137   380	2224019016	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	11/07/2011 12:00:00 AM	ADDRESS	34.19561	-118.49221	TI in an existing office area. plan check is for T-24 Energy Calcs and Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28049	15041-10000-32571	10749 W PICO BLVD	90064	5	126B157   775	4320004092	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.04133	-118.42635	CHANGE OF USE FROM THRIFT STORE TO VETERINARY CLINIC, AND TENANT IMPROVEMENT FOR VETERINARY CLINIC PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28050	19041-10000-14379	3465 W 6TH ST STE 160	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.06373	-118.29761	PC FOR T24 ENERGY ONLY FOR RESTAURANT. SCOPE INCLUDE NEW PANLES AND EQUIPMENT.  TOTAL 1638 SQ.FT .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28051	13041-10000-10594	2043 N CURSON AVE	90046	4	150B177   104	5571028008	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.10923	-118.35612	SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SIZE 8.085 KW. PV1 SYSTEM. PV STANDARD PLAN. USING 33 MODULES. AND COMBINER BOX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28052	18041-20000-03631	1457 N VAN NESS AVE	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.09731	-118.31598	Plan check for power and energy. Project site is an existing commercial building. Project scope is a first time tenant/tenant improvement. Total lighting area = 79,217 sq. ft.Note: Building application has been generated under 18016-10000-02052	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28053	14041-10000-12783	4214 S LINCOLN BLVD	90292	11	105B153    50	4230001010	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	33.98678	-118.44402	Installing a new sprinklermonitoring system with one panel and 4 devices. Core and shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28054	16041-10000-37827	1515 W 190TH ST STE. 165 &-190	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	33.85852	-118.30531	PLAN CHECK FOR ENERGY ONLY. INTERIOR T.I. WORK FOR SPEC #165 AND #190, SCOPE ONLY INCLUDE LIGHTING, NO RECEPTACLE.  TOTAL AFFECTED AREA: 5,002 SQ.FT(B# 16016-10000-22791)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28055	17041-20001-32832	304 S BROADWAY 5th Floor	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.05076	-118.248	12.18.2017 - Plan check for modifications to approved set. Redesign lighting plan - update and recheck T24 documents to reflect changes.=====Tenant improvement to (E) commercial office space.  Plan check for energy - 9,373 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28056	13041-10001-25177	1518 W 15TH ST	90732	15	012B193   258	7560024016	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	10/24/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	33.73078	-118.3106	"changes to approved plans: added 2 modules for a new total of 32 panels. rearranged module layout on roof. 200A main service panel. PV1. ROOF MOUNTED SOLAR ARRAY. ENPHASE 215 MICRO INVERTERS. 32 MODULES. SYSTEM SIZE:6.912 KW AC. 1 STORY HOUSE. ""plan check and permit fee is $0 due to the 2012 Senate Bill No. 1222"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28057	19041-10000-50697	4147 W 62ND ST	90043	8	105B181   861	4003015017	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	33.98363	-118.34768	NOTE: PERMIT FEE IS $0 DUE TO AB 1414. [EPLAN]  Changes to approve set, changes include equipment relocation to inside of garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28058	16041-20000-04861	970 W 190TH ST 1st Floor-Main Lobby	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	33.85812	-118.29302	Plan check for energy only. TI to main entry lobby on first floor of existing high rise office building. New lighting (incl. emergency) and receptacles. 1,682sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28059	12041-10000-20241	12050 W VENTURA BLVD suite#A107	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.14349	-118.39426	REMODEL EXISTING RETAIL SPACE AT THE LAUREL PROMENADE TO BE A SPRINT STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28060	19041-10000-37054	750 S OXFORD AVE	90005	10	132B193   545	5093011013	(T)(Q)C2-2D	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	10/24/2022 12:00:00 AM	ADDRESS	34.05822	-118.30765	PC for FA system to be installed in a new apartment building 7 floors and  300 apartment units. (1)FACP and (1563) Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28061	11041-20000-22348	6922 W HOLLYWOOD BLVD 4th fl.	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	10/19/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.10137	-118.34103	exiting office t.i. remodelEnergy , emergencyFire/ Life Safety system is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28062	15041-20000-07833	2728 W DELOR ROAD	90065	14	159A219   137	5684018016	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.13087	-118.22665	Plan check for PV1 roof mounted 4.2kW system  with 20 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28063	14041-10000-04104	1260 N VINE ST	90038	13	144B189   143	5534001400	C2-1-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.09406	-118.32645	This is a one story bldg, title 24. fast food.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28064	18041-20000-10378	9220 N WINNETKA AVE	91311	12	198B113   131	2761001072		North Valley				1133.03	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.23795	-118.57084	New fire alarm system 311 devices with FACP.  Industrial 4 story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28065	16041-10000-41103	20642 W MERRIDY ST	91311	12	204B109   413	2741029026	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.25272	-118.58338	ROOF MOUNTED PV. TOTAL OF 21 MODULES AND 1 CENTRAL INVERTER RATED 5KW AC. SYSTEM USES POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28066	16041-20000-27753	4151 W PROSPECT AVE Lot C	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Issued	01/05/2017 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of a 1.05 MW fuel cell system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28067	17041-20002-42736	8401 N VAN NUYS BLVD #15	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM			PC Approved	04/02/2018 12:00:00 AM	ADDRESS	34.22308	-118.44896	4/2/2018changes to an approved set of plans.  changes are noted delta B.  changes to match field conditions.  this is plan check only.(((T-24, PC for energy only. TI for an existing commercial space. Scope includes adding new lights for restrooms and corridor space within an existing tenant mall space. Total affected area is 4767 Sq. Ft. B#17016-10000-21521)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28068	14041-20001-29029	17830 W MERRIDY ST	91325	12	204B129   522	2734007003	(Q)R3-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM			PC Approved	11/04/2014 12:00:00 AM	ADDRESS	34.25201	-118.52273	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 26KW(84) CANADIAN SOLAR CSX(1) FRONIUS 11.4-3(1) FRONIUS 10.0.3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28069	15041-10001-40809	5231 N MOUNT HELENA AVE	90041	14	163-5A227 163	5691006039	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/12/2015 12:00:00 AM	ADDRESS	34.1426	-118.19593	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, Install 14.05 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (2)INVERTER: SMA SB7700TL-US-22 & SB5000TL-US-22. (43) modules SUNPOWER SPR327NE-WHT-D>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28070	15041-20000-06472	10100 W SANTA MONICA BLVD 100	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.06191	-118.41691	PLANCHECK FOR TITLE 24 ENERGY. TENANT IMPROVEMENT TO BANK; BANK OF CALIFORNIA. NO CHANGE IN OCCUPANCY. 4151 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28071	14041-20000-14212	5012 N HARTWICK ST	90041	14	162A227   265	5690004015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.1378	-118.1974	PV1 - Solar Standard Plan (Central Transformerless)Install roof-mounted solar array on SFD. System size: 5kW(1) SMA Sunny Boy 5000TL-US transformerless inverter(22) Trina Solar TSM-245 PA05.05 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28072	19041-10000-29767	18101 W SATICOY ST	91335	12	186B125   170	2119005020	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	34.20854	-118.52762	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28073	13041-20000-29306	8621 S RAMSGATE AVE	90045	11	096B169   642	4125013003	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	33.95917	-118.38282	NEW 13 UNIT APARTMENT. RESIDENTIAL ONLY. LOW RISE. PC FOR POWER AND ENERGY. ENERGY FOR GARAGE. FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28074	17041-10000-31212	12466 W MONTAGUE ST	91331	7	201B165     4	2537014052	M2-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.25255	-118.40427	PC for T24 only for removal of outdoor HID fixtures and replace with new LEDfixtures. Total of 196400sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28075	10041-10000-15139	1511 W FRANCISCO ST Bldg B	90501	15	057B193    25	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	33.85075	-118.30473	New building.  New service, panels, and branch circuits.  Plan check for energy and power.  NOTE: refer to 10041-10K-15136 for Bldg A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28076	16041-20000-42278	5750 W WILSHIRE BLVD SUITE 600	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NEWLY CONNECTED LOAD LESS THAN 400 AMPS PER APPLICANT. 15,797 SQFT . SUITE 600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28077	16041-20002-41120	870 S HILGARD AVE	90024	5	135B153   384	4360007028	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.06469	-118.4407	11.29.2016 - Plan check for modifications to approved set. Changing two PVI 14 kW  inverters to Fronius Symo 10kW and 12kW inverters respectively. Reducing system size from 70kW to 64kW. DC side of system is unchanged. Delta 1 changes. This plan check is supplemental to application #16041-20000-08868. The current application was supplemented by mistake.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28078	14041-20000-17371	5555 W MELROSE AVE 1st , 2nd-floor	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR TITLE 24 ENERGY LIGHTING.  EXISTING TWO STORY COMMERCIAL BUILDING.  ALL CIRCUITS ARE EXISTING. NO NEW LOADS. WORK TO BE PERFORMED IN FIRST AND SECOND FLOOR. BUILDING 256	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28079	17041-20000-25389	6001 N DE SOTO AVE	91367	3	177B105    72	2149005033	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Issued	12/04/2017 12:00:00 AM	ADDRESS	34.17944	-118.59076	Plan check for power and energy. Project site is an existing commercial building. Project scope is a service upgrade from 800 amps to 1,600-amps and outdoor building facade lighting. Total lighting area = 7,338 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28080	19041-20000-52350	11625 W OLYMPIC BLVD	90064	11	123B149   326	4260007028	(T)(Q)C2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	07/01/2020 12:00:00 AM		Permit Finaled	11/18/2020 12:00:00 AM	ADDRESS	34.0352	-118.4466	$0 PERMIT FEE DUE TO SB1222 AND AB1414PV3.  Install 162 KW DC/146.96 AC CEC roof mounted PV system.  (405) modules with (4) 33.3 kW inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28081	19041-20000-45897	20357 W TUBA ST	91311	12	204B113   224	2741008022	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.25639	-118.57697	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 14.025 KW DC/12.3 KW AC CEC. SCOPE OF WORK CONSISTS OF (55) PV MODULES WITH OPTIMIZERS AND A 11.4 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28082	18041-10001-46011	216 S LAKE ST	90057	13	135A205    63	5154008019	R3-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Apartment			12/04/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	ADDRESS	34.0657	-118.27208	EXPEDIATE PER APPLICANT REQUEST NEW ROOFTOP SOLAR SYSTEM CONSIST OF 50 MODULES (SUNPOWER X-SERIES X22-360) AND 1 CENTRAL INVERTAR (SUNNY BOY 7.7-US 240V/7950W). SYSTEM SIZE IS 18KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28083	10041-10000-13211	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM			PC Approved	07/13/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I. suite 159. Title 24 only retail area.   Light spec sheet is attached to plan.  Fixtures not to exceed wattage per spec sheet.  Caslculation based on max wattage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28084	13041-20000-07825	22636 W VENTURA BLVD	91364	3	171B097   307	2040032033	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Closed	07/01/2013 12:00:00 AM	ADDRESS	34.16686	-118.61984	Change of use from Retail to New Dentist/Medical.   Full Plan Check.  Licensed Medical per Applicant.  CHECK FOR OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28085	14041-20001-14544	18747 W WELLS DR	91356	3	171B121   411	2161012012	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			Plans on Hold	06/05/2014 12:00:00 AM	ADDRESS	34.16329	-118.54081	((expedite fees))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28086	13041-10000-26977	3781 S CIMARRON ST	90062	8	117B189   568	5035028032	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	PIN	34.01813325	-118.31635973	PV1. ROOFMOUNTED SOLAR ARRAY. 2 STORY HOUSE. TRANSFORMERLESS INVERTER. UNGROUNDED SYSTEM. SYSTEM SIZE: 1.715 kW.(7) YINGLI # YL245P-29b(1) POWER-ONE # AURORA PV1-3.0-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28087	13041-20000-04247	17221 W SUNBURST ST	91325	12	195B133    27	2690001004	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	05/08/2013 12:00:00 AM	ADDRESS	34.23462	-118.50944	New roof mounted PV system with 3.995 KWdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28088	14041-20000-16156	13809 N MINDORA AVE	91342	7	228B161   286	2511032022	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.32265	-118.41596	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.5KW INTERCONNETED WITH MSP.34 MODULES SMX250 / 34 MICROINVERTERS ENPHASE 215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28089	16041-30000-29126	2049 S CENTURY PARK EAST 15th FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing space High-rise building men and women restroom 15th Floor. Total lighting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28090	15041-20000-02647	12500 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28091	19041-10000-31740	1765-1767 W ADAMS BLVD	90018	8	123B193   570	5058029013	C1-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.03287	-118.30213	PC ENERGY ONLY FOR CONVERT 1-STORY RETAIL BLDG. INTO 2-STORY OFFICE/STORAGE/RETAIL/SHOWROOM. AREA SCOPE 2,802SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28092	19041-20000-28300	2961 N DONA EMILIA DR	91604	2	156B173   216	2380025014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Issued	08/02/2019 12:00:00 AM	ADDRESS	34.12541	-118.37733	PV1.  Install 6.51 kW DC roof mounted grid tied PV system.  (21) modules with 6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28093	14041-10000-18639	7419 N BECK AVE	91605	2	186B169   638	2316016015	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.20533	-118.38355	Install roof mounted solar PV system on existing residential building.  Total system size = 7.2 kW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28094	15041-10000-00589	12655 W BLUFF CREEK DR 1-125	90094	11	102B161  1281	4211037037	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/08/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	33.97565	-118.41332	Plan check for power and title 24.  New 4 story 125 unit residential condominium with 2 subterranian parking levels.  6 typical units.  Building is located in methane zone.  Fire alarm plans to be submitted by contractor at a later time.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28095	19041-30000-17369	429 N HAYWORTH AVE	90048	5	141B177  1362	5527032021	R3-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Apartment			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM	ADDRESS	34.07898	-118.3629	Plan check for a fire alarm system for a 4-story, 16-unit apartment building. Fire alarm consists of (1) FACP and (94) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28096	18041-20001-24250	20929 W VENTURA BLVD 26	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM			PC Approved	09/06/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	09-06-2018 Changes to an approved set of plan, changes include modify panel number from Panel Unit 26 to Panel Unit 26A and Unit 26B. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28097	13041-10000-14484	12811 W VICTORY BLVD	91606	2	180B161  1049	2325032004	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM			PC Info Complete	06/04/2013 12:00:00 AM	ADDRESS	34.18685	-118.41216	Change of use from retail to restaurant.  A2 occupancy, emergency lighting and exit signs required.  Newly connected load < 400A; title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28098	19041-10000-12874	6801 W HOLLYWOOD BLVD C1-134	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.10229	-118.33907	POWER AND ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT. CHANGE OF USE FROM FOREVER 21 TO CAPITAL ONE BANK OFFICE, ATM, AND CAFE SPACE. SCOPE INCLUDES NEW TRANSFORMER AT 112.5kVA, EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS IS 9887SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28099	16041-10000-21090	6510 W FOOTHILL BLVD	91042	7	201A203   184	2564012036	C2-1VL, R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM			PC Info Complete	07/18/2016 12:00:00 AM	ADDRESS	34.24495	-118.27398	"PC for T-24 only. Commercial tenant improvement to existing 1-story restaurant ""McDonald's"".. Total affected area: 6,255 sq. ft.B# 16016-10000-13935"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28100	11041-10000-14042	15222 W VENTURA BLVD	91403	5	168B145   995	2276007058	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			07/07/2011 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.15331	-118.46466	NEW 5-STORY MIXED USE RESIDENTIAL AND COMMERCIAL BUILDING.  50 RESIDENTIAL UNITS WITH COMMERCIAL SPACE BELOW.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28101	13041-10000-23209	18220 W CLARK ST	91356	3	174B125   571	2160018144	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.16965	-118.52984	PV1 - Plan check for new roof mounted photovoltaic system. 8.33KW. SolarEdge Transformerless inverters with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28102	15041-20000-41019	7339 N KELVIN AVE	91306	3	186B109   809	2113013026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.20394	-118.58641	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP.  TOTAL SYSTEM SIZE IS 3.8KWac. (10)MODULES-CANADIAN SOLAR 310(10) POWER OPTIMIZER-SOLAREDGE P405(1)INVERTER-SE-3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28103	17041-10000-39229	2111 N GRIFFIN AVE	90031	1	136-5A223  28	5204018006	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.06975	-118.21183	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28104	12041-10000-10024	504 S HARBOR BLVD	90731	15	015B201   221	7440030***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	33.74047	-118.27853	PLAN CHECK POWER AND ENERGY FOR PORT OF LOS ANGELES WATERFRONT IMPROVEMENT. NEW 2500A SERVICE AND EQUIPMENT. FLOATING DOCKS UNDER #10041-10000-25470 AND MUSEUM #11041-10000-21482.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28105	13041-20003-35418	826 N LA CIENEGA BLVD	90069	5	141B173   115	5529006057	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.08614	-118.37626	New plans for restaurant remodel.  Title 24 plan check only.  (((Interior nonstructural remodel of (E) restuarant and add outdoor dining.  Title 24 plan check only per supervisor request.  5,860 sq. ft. interior conditioned and 785 sq. ft.  illuminated hardscape area.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28106	14041-20000-21178	19378 W PATIRENE PL	91335	3	180B117   528	2131007010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.19027	-118.55615	PV1.  Install 4.734 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28107	16041-20000-33721	4151 W PROSPECT AVE Bldg V-Stage 5	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM			PC Approved	09/22/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for energy only. Remodel bathrooms and dressing rooms. New lighting (incl. emergency) and receptacles. 942sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28108	17041-10000-20034	7034 N TAMPA AVE	91335	3	183B117   395	2129007007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.19844	-118.55331	plan check for battery back-up system(5.8KVA tesla powerwall2) on single family dwelling with 125A load center panel. Existing PV under permit 16041-90000-22911.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28109	13041-20000-23528	738 N WILCOX AVE	90038	13	141B185   386	5533034018	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			08/28/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.08463	-118.33083	Plan check for fire alarm. New panel and 352 devices. New Apartment Building. Broadstone Hancock Park.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28110	19041-10000-45378	7119 N FAIR AVE	91605	2	183B173   126	2319022006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	07/14/2023 12:00:00 AM	ADDRESS	34.19995	-118.37508	$0 DUE TO AB1414NEW PV2 INSTALLATION. SCOPE OF WORK INCLUDES 324 MODULES, 162 OPTIMIZERS, AND 1 CENTRAL INVERTER. *NOTE: NEW MAIN SERVICE PANEL SHALL BE PULLED UNDER A SEPARATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28111	18041-20000-23779	619 S JUNE ST	90005	4	135B185   425	5507017011	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM			PC Approved	06/26/2018 12:00:00 AM	ADDRESS	34.06426	-118.33475	Plan check for power only for service upgrade to 600A under methane zone. Plan check only, Permit refer to Building application under Combination Permit 14014-20000-03088	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28112	15041-10000-20238	610 W FLORENCE AVE	90044	8	102B201   919	6020028005	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	33.97439	-118.28428	Full plan check for service upgrade from (2) 200-Amp single phase 120/240 to (1) 800-Amp 3-phase 4-wire 120/240V; All existing load will reconnect to new service equipment. Total T24 area is 6805-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28113	19041-30000-48980	601 S FIGUEROA ST 2750	90017	14	130-5A209 175	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCUDES NEW LIGHTING AND RECEPTACLES LOADS. TOTAL SQ. FT. FOR ENERGY PC: 5090.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28114	14041-20000-00053	17550 W LANARK ST	91325	12	189B129   142	2201005008	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.21786	-118.516	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTERS USING POWER OPTIMIERS. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28115	14041-10001-34357	14006 W RIVERSIDE DR # FC-9	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			Corrections Issued	03/11/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Changes to approved set.  Minor changes to lighting design.  (((TENANT IMPROVEMENT OF EXISTING RESTAURANT AT THE MALL FOOD COURTPLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28116	11041-10000-24689	251 N ROBINSON ST 1-18	90026	13	139-5A201 247	5156003006	RD1.5-1	Central	Westlake	Rampart Village	YES	2086.10	Electrical	Electrical	Apartment			11/17/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.07552	-118.28246	new fir alarm for a two story , 18 nunits apartment bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28117	10041-10000-07022	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***	A1-1XL-H, RE40-1	Central	Hollywood	Hollywood Hills West	YES	1882.00, 1897.01	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.1504	-118.32742	coverting overhead power line on the owner side of the system to undergound wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28118	16041-30000-04610	14431 W COHASSET ST	91405	2	186B149   289	2215026009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.20677	-118.44749	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.6 kWac.  Central inverter system with 3 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28119	17041-20002-31690	3019 E ASBURY ST	90065	1	147A217    68	5454031025	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.09865	-118.23001	07-31-2018 Changes to an approved set of plan, changes include addtion of disconnect. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28120	12041-10000-05208	444 S FLOWER ST 32ND FL	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	ALTERATIONS IN OFFICE TENANT SPACE - CORRIDORS; OFFICES AND LUNCH ROOMS AND ELEVATOR LOBBY PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28121	18041-20000-26897	339-341 N GLENDALE BLVD	90026	13	136-5A207 349	5159020024	C2-1VL	Central	Westlake	Echo Park	Yes	2083.02	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM			PC Info Complete	07/18/2018 12:00:00 AM	ADDRESS	34.06657	-118.26072	ti to an existing commercial building.  adding new lighting new controls to existing and new panel.  newly connected load <400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28122	15041-10000-06672	1934 W OLYMPIC BLVD	90006	1	130-5A203 248	5136011022	C4-1	Central	Westlake	Pico Union		2095.20	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.05087	-118.27855	T24 only of a restaurant.  No new panels.  total area = 1192 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28123	19041-20000-25591	1303 S ORANGE GROVE AVE	90019	10	129B177   144	5086004012	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			07/03/2019 12:00:00 AM	01/04/2022 12:00:00 AM		Issued	01/04/2022 12:00:00 AM	ADDRESS	34.05299	-118.36508	FULL PLAN CHECK FOR NEW. SERVICE SIZE OF 1200A. SCOPE INCLUDES A 1200A MDP, 400A MDP, (35) 100A PANELS, A 40HP ELEVATOR MOTOR, AND A 150A PANEL.  9 TYPICAL UNIT TYPES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28124	13041-20000-19920	20734 W SARDINIA WAY	91326	12	213B109   568	2701071001	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.28072	-118.58513	New rooftop mounted PV system for an existing single family dwelling.  System is UNGROUNDED.  Conduit is attached directly to the last module in each string to comply with 690.35(D)(2) per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28125	11041-10000-16114	8755 N WOODMAN AVE	91402	7	195B153   900	2637004036	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	09/12/2011 12:00:00 AM	PIN	34.22896531	-118.43609748	New 600 amp service to provide power for portable units.  Plan check is for power,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28126	16041-10000-41819	12897 W WINGO ST	91331	7	201B161   264	2624009022	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.24988	-118.41373	PV INSTALL NEW 7.42 KW DC/7.6 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(28) MODULES: AXITEC AXIPOWER AC-265P/156-60S(1) INVERTER: FRONIUS primo 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28127	13041-10000-10596	13511 W SHADY PALMS LANE	91342	7	222B157   915	2513009064	(Q)RD2-1	North Valley	Sylmar	Sylmar	YES	1061.14	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.30599	-118.42788	PV1 TWO STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.39 KW. [INVERTER: SOLAR EDGE SE5000A--US] [SOLAR MODULE: TRINA SOLAR TSM-245-PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28128	19041-20000-52883	2810 N OAK POINT DR	90068	4	156A181   459	2428008015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.12169	-118.3507	PV1.  Install 2.64 kW roof mounted PV system.  (8) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28129	16041-20000-15351	14006 W RIVERSIDE DR #41	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only for existing space for TEAVANA. Total area: 1,572 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28130	19041-20000-14290	10529 W WYTON DR	90024	5	138B153   267	4359004009	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.07312	-118.43611	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.16KW DC/8.99KW AC/10.15KW AC CEC. SCOPE OF WORK INCLUDES (31) PV MODULES WITH ENPHASE IQ7+ MICROINVERTERS AND A 100A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28131	15041-10000-16270	3700 N COLDWATER CANYON AVE	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.13809	-118.41286	NEW LUMINAIRES IN TECHNOLOGY RESEARCH CTR LOCATED IN THE MUNGER LIBRARY ON THE HARVARD WESTLAKE CAMPUSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28132	12041-20000-15461	14600 W ROSCOE BLVD	91402	6	192B149   406	2210010033	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.22136	-118.45025	Dialysis Center.  Plan check power and emergency lighting.  Exempt from T24 as I-2.1 Occupancy.  Variance to separate the fire alarm system was submitted on December 10, 2012.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28133	14041-20000-11337	15932 W NORDHOFF ST	91343	12	198B141   703	2672005051	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.23544	-118.47938	pv1 single family dwelling. total system size 860 watts. using microinverter enphase m215. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28134	13041-10000-21306	1024 W 65TH PL	90044	8	102B197    16	6014012011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	33.97974	-118.29271	PV1.  Install 1.728 kW roof-mounted solar array, interconnect into main service panel.  {8 modules: Aleo S186250} {Microinverters: M215-60-2LL-52x}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28135	15041-10000-05251	1141 S SANTEE ST	90015	14	124-5A209  38	5145021017	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.03687	-118.25701	REPLACING SERVICE 800A T AN EXISTING BUILDING; NO CHANGES IN THE LOAD; SERVICE REPORT, SITE PLAN, LOAD CALCULATION AND ELEVATION DRAWING OF SERVICE EQUIPMENT ARE ON THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28136	14041-20001-13596	4371 S GLENCOE AVE	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	33.9857	-118.43834	[[6/28/16 CHANGES TO APPROVED SET.  ARCHITECTURAL REVISIONS RESULTING IN CHANGES TO ROOM CONFIGURATIONS, HOMERUNS, PANEL LOADS.  CHANGES TO LIGHTING SYSTEM. DELTA-2 AND 3 REVISIONS ONLY]]PLAN CHECK FOR ENERGY AND POWER.Renovation of existing building to a restuarant (change of use). New 400 amp service. 2660sqft. Regular plan check required due to building occupancy load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28137	14041-20000-23472	6957 N WISH AVE	91406	6	183B133   586	2230002024	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.19716	-118.50706	PV1 SFD. TOTAL SYSTEM SIZE 9KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. DERATE MAIN BREAKER. SYSTEM USES 44 MODULES AND POWER OPTIMIZERSFIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28138	12041-20000-30618	790 S CERES AVE	90021	14	124-5A213 267	5146003040	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Closed	01/15/2015 12:00:00 AM	ADDRESS	34.0357	-118.24511	Change to lighting for an Existing Retail space.  Load is 67 amps and occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit Fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28139	13041-10000-08064	10459 W TUXFORD ST	91352	7	198B177   137	2544014003	A1-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.23764	-118.35908	CONSTRUCTION OF NEW CLASSROOMS AND OUTDOOR LIGHTING. PC FOR T24 ENERGY ONLY. LOW ADDITIONAL LOAD. PWERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28140	19041-10000-30779	1240 S WEST BLVD	90019	10	129B185   402	5082011903	OS-1XL	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.05038	-118.3329	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28141	15041-20000-09932	18241 W CHATSWORTH ST	91326	12	207B125   264	2715009014	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.26468	-118.53073	Installation of new roof mounted solar PV array.  Total system size = 5.59 kWac.  Microinverter system with 26 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28142	16041-20000-31144	7030 N JAMIESON AVE	91335	3	183B129   427	2121029016	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.19853	-118.52142	PV1. ROOFMOUNTED SOLAR SYSTEM. ADDITION TO EXISTING SYSTEM 2.43KW. TOTAL  6.5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28143	19041-20000-30690	16633 W VENTURA BLVD #1200	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for Title 24 Energy only in existing building Tenant Improvement. Total area: 3305 sq ft. B#19016-20000-16065	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28144	14041-20000-11826	8976 N LAUREL CANYON BLVD	91352	6	195B165   167	2629019021	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			Reviewed by Supervisor	05/20/2014 12:00:00 AM	ADDRESS	34.23276	-118.40423	MAJOR SYSTEM DESIGN CHANGES. NEW SUBMITTAL. THIS APPLICATION TO BE WITHDRAWNCHARLES@SOLARTECUSA.COMPC FOR PV SYSTEM COMMERCIAL ROOFTOP. PV2. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERED INVERTER. NONSTANDARD PLAN. 2 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28145	19041-10000-08153	426 W PICO BLVD #1C	90015	14	126A207   175	5134017032	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.03914	-118.26526	"FIRST TIME TENANT IN UNIT ""ONYX EAST RETAIL"" SUITE#1C. PLAN CHECK FOR POWER & ENERGY.BULDING PERMIT: 19016-10000-02754"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28146	13041-10000-08067	4827 E HUNTINGTON DR NORTH	90032	14	142-5A233  61	5213002011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	04/16/2013 12:00:00 AM	ADDRESS	34.08611	-118.17939	T24 FOR EXISTING RETAIL SPACE. 2424 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28147	13041-20000-15658	1967 N MYRA AVE	90027	4	150B201   667	5591017002	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.10745	-118.28015	PV1 PLAN CHECK FOR 3.90KW SOLAR SYSTEM. 13 MODULES AND 1 INVERTER TRANSFORMERLESS SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28148	18041-10000-39302	380 WORLD WAY TBiT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT - NO CHANGE OF USE (SAME STORE) - TOTAL AFFECTED AREA = 1395 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28149	14041-10000-21308	21037 W SUPERIOR ST	91311	12	201B105   179	2746003001	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.24647	-118.59185	Remove HID light fixtures and replace with new fluorescent fixtures. T24 plan check. Area = 3952 sq. ft. 5 units	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28150	13041-10000-10124	13834 W MAGNOLIA BLVD	91423	2	171B153   470	2269006005	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.00, 1287.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.16472	-118.43467	PV1 SYSTEM.  solar system for single story dwelling. utilizing central inverter. inverter - sma 5000. solar panel - hanwha 190.  5.1KWDC/4.4KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28151	15041-10000-14708	15400 W SHERMAN WAY SUITE 105	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Info Complete	05/14/2015 12:00:00 AM	ADDRESS	34.20099	-118.46839	TI TO AN EXISTING THREE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  SCOPE OF WORK TO BE IN SUITE 105.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28152	15041-10001-35163	9270 W SIERRA MAR DR	90069	4	144B165    84	4392009021	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	34.09471	-118.39361	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1. INSTALL 11.04 KW DC ROOF-MOUNTED SOLAR AARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: SUNPOWER X21-345(1) INVERTER: SOLAREDGE SE11400A-US 240>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28153	16041-20001-24561	2191 W 28TH ST	90018	10	123B189   978	5052029013	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.03005	-118.31469	EXPEDITE PER APPLICANTPV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.6KW INERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28154	16041-10001-39764	12300 W WILSHIRE BLVD STE-404	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.04245	-118.46922	01/17/17Changes to an approved set of plans. Changes include specifying emergency luminaires on the lighting floor plans and removing one exit sign.Note: Permit is paid under 16041-10000-39764	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28155	18041-20000-07400	13637-13649 W VANOWEN ST	91405	2	183B157   964	2328013042	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.19408	-118.43027	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28156	18041-20000-30523	5030 S 6TH AVE	90043	8	111B189  1513	5014017007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	33.99689	-118.32344	Paln check for PV roof mounted addition to existing system, new PV system size: 4.1 KW AC with 13 new modules and 13 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28157	19041-20000-53849	7415 S MAIN ST	90003	9	102B201  1293	6031007024	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Apartment			12/31/2019 12:00:00 AM	12/29/2023 12:00:00 AM		Issued	12/29/2023 12:00:00 AM	ADDRESS	33.97225	-118.27408	Install 600A 240/120V 1ph-3w service, distribution, power, and lighting for new apartment building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28158	13041-10000-22561	120 S LOS ANGELES ST	90012	14	130-5A213  98	5161016027	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.05092	-118.24262	Existing restaurant renovation on ground floor of Doubletree Hotel, exterior storefront and signage, relocation of bar, new walk-in refrigerator, new lighting, and enlargement of breakfast buffet area.  A-2 occupancy - power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28159	16041-10000-39087	1015 W FIGUEROA TER 1-22	90012	1	136-5A213  45	5406022078	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			11/03/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.0687	-118.24529	PC FOR NEW FIRE ALARAM  FOR AN APARTMENT BUILDING. SCOPE INCLUDES TOTAL OF 7 FA PANELS AND 251 FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28160	17041-10000-19235	7405 N VAN NUYS BLVD	91405	6	186B149   533	2218004014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.20517	-118.44975	PC for T24 only for outdoor lighting. PC for replacement of 13 HID units with new LED fixtures. Total area of 18850 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28161	12041-10000-21358	5736 N WOODLAKE AVE	91367	3	174B093   162	2041016021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.17475	-118.63189	225A Main service panel upgrade for PV interconnection. Existing service.	N	N	Express Permit	06/10/2024 12:00:00 AM
28162	12041-10000-29966	111 S PACIFIC AVE	90731	15	018B197  1223	7451008027	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	33.74297	-118.28804	CHANE FROM GROCERY TO FAMILY DOLLAR MARKET. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28163	18041-20000-47496	21345 W DEERING CT	91304	3	189B105   117	2109001020	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			12/14/2018 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	02/13/2024 12:00:00 AM	ADDRESS	34.21659	-118.59627	New 400A 480Y/277V 3ph-4w service.  New distribution equipment, lighting circuits, and controls.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28164	17041-20000-11816	8521 N FALLBROOK AVE STE 380	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.22368	-118.62797	"PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR OFFICES. "" FLAVOR PRODUCERS ""  (12,380sf) SUITE 380"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28165	19041-10000-41442	1166 S SOTO ST	90023	14	121-5A221  24	5170005026	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Info Complete	11/22/2019 12:00:00 AM	ADDRESS	34.02828	-118.2191	PC FOR A TI, SCOPE OF WORK INCLUDES TWO NEW PANELS CONNECTED TO AN EXISTING 800 MAIN SERVICE SWITCHBOARD (120/240), TOTAL AFFECTED AREA IS 5640 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28166	16041-10000-10164	160 W AVENUE 28	90031	1	141A221   242	5205019008	RD3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.07962	-118.21685	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (9) MODULES, SPR-E20-327, AND (1) INVERTER, SMA AMERICA, SB3000TL-US-22. TOTAL SYSTEM SIZE IS 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28167	15041-20003-28031	1638 E VERNON AVE	90011	9	112-5A213  86	5106003025	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	34.00372	-118.24454	02/17/2016 Changes to an approved set of plans. Changes have been made to the PV module layout.12/17/2015 Plan check for a lost set of PV plans. System has remained the same. Permit to be pulled under master application.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. Systems size is 5 kWac and consists of (1) inverter, (24) modules, and (24) power optimizers. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28168	15041-10000-17133	7402 S AGNEW AVE	90045	11	102B161   148	4110025035	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	33.97302	-118.40919	PV1 11KW Ac roof-mounted system with (35) Sunpower SPR-E20-327 modules, (1) SMA America SB5000TL inverter and (1) SMA America SB6000TL iverter inter connecting through the service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28169	15041-20000-03443	18528 W CHASE ST BUILDING B	91324	12	192B125   315	2785018029	R3-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Apartment			02/04/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.22434	-118.53707	PC FOR 17 UNIT APARTMENT. TOTAL UNITS ON LOT 28. THIS IS SUBMITTAL 2 OF 2. THIS PLAN CHECK IS FOR 17 UNITS LOCATED AT BUILDING B. BOTH BUILDINGS ARE SERVED BY A SINGLE UTILITY TRANSFORMER.FIRE ALARM VARIANCE HAS BEEN FILEDPC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28170	16041-10000-33840	1311 W SEPULVEDA BLVD	90501	15	045B193   791	7347018097	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			09/23/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Closed	03/28/2019 12:00:00 AM	ADDRESS	33.81492	-118.30044	Plan check for power only Temp Power for 176 units appartment 6 story building using main distribution of the building as temp power distribution equipment (2) 600 A  Delta 4 in Single Line Diagram and associated loads. Fault current  available on LADWP web site 31kA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28171	17041-20000-13259	5165 W FOUNTAIN AVE	90029	13	147A195   255	5544038018	R3-1, RD1.5-1XL	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Issued	05/02/2017 12:00:00 AM	ADDRESS	34.09528	-118.30183	"800 amp service upgrade to an existing commercial building core and shell.  adding new distribution board ""MSA"" and reconnecting existing panels, panels A1 B1 C1 are empty panels.  this is plan check for power only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28172	16041-20000-20254	803 E 76TH PL	90001	9	099B209    76	6023019031	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	33.97038	-118.26055	Plan check for PV roof mounted system. System size: 3.0kW with 12 modules and 1 inverter(3.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28173	15041-10000-03505	2170 CENTURY PARK EAST	90067	5	132B161    54	4329001241	R4-2-O	Central	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	PIN	34.05796454	-118.41041209	Energy plan check for a boiler room located in a common underground parking lot of 2-condo building structures. Partial permit fee is paid under permit #: 14041-10000-36005	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28174	19041-10000-16394	20640 W VENTURA BLVD	91364	3	171B109    75	2166013101	(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.16697	-118.58271	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28175	14041-10000-18167	416 W PICO BLVD	90015		126A207   179	5134017004							Electrical	Electrical	Apartment			07/07/2014 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.03903	-118.26506	7 Story Mix-Use Building (6 story Type III-A 162 units apartment over one story Type I-A ground level retail) over 2 level subterranean parkin garage -14010-10000-01138	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28176	15041-10000-40572	17151 W WILLARD ST	91406	6	192B133   461	2204004007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.21885	-118.50726	PC FOR 4.3KW AC PV SYSTEM. USING MICROINVETERS. ENPHASE M215. 20 MODULES TOTAL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28177	14041-20000-17861	3229 W CASITAS AVE	90039	13	153B209   518	5436002027	MR1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.11548	-118.25102	Plan check for power and energy on a TI commercial building; service and switch board A are existing.  all the load on switch board A, B and switch board B itself are added as new load. Tittle 24 will base on 2008 stadard energy code due to previous Plan submitsion. permit #: 14041-20k-17702.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28178	15041-20000-34112	12126 W VICTORY BLVD	91606	2	180B165   760	2334001063	C2-1L, P-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.1865	-118.39765	Plan check for power and energy per Article 517. Project site is an existing outpatient dialysis clinic. Project scope is a tenant improvement. Work includes the addition of approximately 4,000 sq. ft. of foor area. Project is OSHPD-3.Note: Building application has been filed under 15016-20000-22279	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28179	14041-10000-21056	11740 W SAN VICENTE BLVD #208	90049	11	129B145    75	4265006074	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.05308	-118.4669	Title 24 only, New code. Lighting/ electrical to existing commercial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28180	15041-10000-43367	606 E VENICE BLVD Bldg E	90291	11	108B145  1741	4237002007	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	33.98922	-118.46166	PC for energy only, Ti to an existing building, employee fitness facility (building E). Newly connected load less than 400 A. Total Sq ft = 5495	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28181	19041-20000-43975	659 N CRANE BLVD	90065	1	150A223    83	5466006012	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.10696	-118.21041	PV1.  Install 4.06 kW roof mounted grid tied PV system interconnected to center-fed panelboard.  (14) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28182	18041-10000-45901	15222 W KESWICK ST	91405	6	186B145    13	2209034029	CM-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.21017	-118.46479	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28183	13041-10000-20559	980 N WESTERN AVE A	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	33.7515	-118.30878	pc for energy only. permit to be pulled at EPC counter only. INTERIOR TI TO (E) CHASE BANK.NON STRUCTURAL TI TO (E) CHASE BANK; NON BEARING PARTITIONS TO CONVERT (2) CUBICLES TO (2) PRIVATE OFFICES; NEW E-MERCH DISPLAY WALL BEHIND TELLER LINE; NEW CEILING AT NEW OFFICES; APPLYING UNREASONABLE HARDSHIP UPGRADES <SEE COMMENTS>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28184	11041-20000-26570	3616 S TROUSDALE PKWY	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM	ADDRESS	34.01983	-118.28534	energy plan chek offices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28185	19041-10000-16401	10802 S COMPTON AVE	90059	15	088-5A213 106	6069001001	[Q]C1.5-1VL	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	33.93765	-118.24612	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28186	18041-30000-16940	8700 W BEVERLY BLVD Davis Bldg-G-140	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Closed	08/21/2018 12:00:00 AM	ADDRESS	34.07666	-118.3805	"Plan check for power only: add (2) new equipment inside the lab room G151. Scope of work is clouded as Delta-2. New circuits fed from existing panelboard ""GJJ"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28187	12041-10000-16666	13451 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15778	-118.42648	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28188	14041-10000-10495	5213 E MONTE VISTA ST	90042	1	151-5A227 248	5469019024	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	Apartment			04/22/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.10885	-118.2008	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28189	17041-10000-16874	3421 E 14TH ST	90023	14	118-5A225 335	5190033004	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.01734	-118.206	Power plan check.  Service upgrade to 3,000 amp 480/277 volts for industrial kitchen and warehouse building.  All loads to remain existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28190	14041-20000-10081	3366 N WRIGHTWOOD DR	91604	2	159B173   314	2380038003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.13268	-118.37316	PV1.  Install 5.5 kW roof-mounted PV system, interconnect with main service panel.  (22) modules.  Transformerless inverter: Power One PVI-5000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28191	17041-20001-21938	22144 W ALIZONDO DR	91364	5			RA-1	South Valley	Encino - Tarzana	Encino	Yes	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM			PC Approved	07/12/2017 12:00:00 AM	ADDRESS	34.15056	-118.60691	expeditepv1install roof mounted pv system sized 12.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28192	14041-20002-14670	401 S GRAND VIEW ST	90057	1	135A203   316	5154036012	R3-1	Central	Westlake			2088.02	Electrical	Electrical	Apartment			06/18/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.06322	-118.27542	Plan check only due to original plans being lost under #14041-20000-14670.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28193	12041-20000-27467	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.05554	-118.41342	Change to lighting in 31st floor elevator lobby.  No new circuits.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28194	16041-20000-40325	1408 N POINSETTIA PL Unit #D	90046	4	147B181   927	5548019036	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.09607	-118.3481	Plan check for power only. New SFD - unit D - part of 5 attached SFDs fed from (N) common 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28195	16041-20000-40299	12420 W EVERGLADE ST	90066	11	114B153    85	4247026001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.01231	-118.44122	Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with 200A MSP.4.32kW ungrounded system. (12) 360W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28196	19041-20000-07671	1554 N BEVERLY DR	90210	4	147B161   159	4355013016	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.0994	-118.4148	Installation of 27 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28197	11041-10000-02803	928 S WESTERN AVE #302	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	03/03/2011 12:00:00 AM	ADDRESS	34.05485	-118.30886	alterations in the waiting room of a shopping centerplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28198	19041-10000-41312	630 W HARRY BRIDGES BLVD BLDG 515	90744	15	027B205   429	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	33.77068	-118.26868	NEW METHANE DETECTION SYSTEM WITH 10 DEVICES IN BUILDING #515.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28199	16041-10000-42936	17425 W DEARBORN ST	91325	12	198B129   336	2766011041	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.23726	-118.51443	Plan check for PV roof mounted system size: 13.8kW with 50 modules and 3 inverters(4.6kW) NINGBO GINLONG TECHNOLOGIES : SOLIS-4.6-2G-US. Connected to existing MSP 200A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28200	12041-10000-23884	1566 W COLORADO BLVD	90041	14	162A227   108	5689018021	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.13932	-118.20035	INSTALL A NEW SPRINKLER MONITORING SYSTEM IN TRADER JOES #55.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28201	10041-20001-19148	924 S WESTWOOD BLVD # 920	90024	5	135B153   539	4363019902	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM			PC Info Complete	10/08/2010 12:00:00 AM	ADDRESS	34.06308	-118.44513	Changes from previously approved plans.  Changes include the installation of the emergency lighting control unit (ELCU-100) without using emergency unit equipment in a high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28202	17041-20000-01807	22626 W CAVALIER ST	91364	3	168B097   183	2076001037	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	Yes	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	03/04/2017 12:00:00 AM	ADDRESS	34.15931	-118.62086	Plan check for a PV1 roof-mounted PV system. System size is 9.7 kWac and consists of (28) AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28203	13041-20000-15898	10055 N MASON AVE PV-1	91311	12	204B109   366	2741024043	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.25337	-118.57999	PV-1. One 3kW inverter. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28204	14041-20000-16742	16906 W SCHOOLCRAFT ST	91406	6	183B133   727	2230007014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Expired	08/02/2016 12:00:00 AM	ADDRESS	34.19627	-118.50164	PV1 SINGEL FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER, 18 MODULES WITH POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28205	14041-20000-34870	601 S FIGUEROA ST 46th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for energy only. TI to common corridors/elevator lobby and restrooms on 46th floor of high rise office building. New lighting (incl. emergency). 2,136sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28206	19041-10000-41369	6657 N LAUREL CANYON BLVD	91606	2	180B165   234	2322004070	C2-1L, P-1, P-1L	South Valley	North Hollywood - Valley Village	NoHo		1233.01	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	04/26/2021 12:00:00 AM		Permit Finaled	02/04/2022 12:00:00 AM	ADDRESS	34.19192	-118.39674	CHANGE OF USE FROM GROCERY STORE TO FITNESS CENTER. INSTALLING NEW PANELS, TRANSFORMER & EQUIPMENT. AFFECTED AREA: 23,550 SFT.BULDING PERMIT: 19016-10000-31801	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28207	10041-10000-01565	2870 W ROWENA AVE	90039	4	151-5A207 162	5434033034	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM			PC Approved	01/28/2010 12:00:00 AM	ADDRESS	34.10775	-118.26679	New lighting in a restroom.  T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28208	16041-20000-08117	3664 N WILLOW CREST AVE	91604	2	159B173    37	2380006006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Issued	03/15/2016 12:00:00 AM	ADDRESS	34.13615	-118.36756	$0 permit fee due to State Senate Bill SB-1222. Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28209	16041-10000-22519	13274 W FIJI WAY 3rd Floor	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	33.97902	-118.43558	COMMON AREA AND ELEVATOR LOBBY UPGRADES. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28210	19041-10000-44526	17347 W SAN FERNANDO MISSION BLVD	91344	12	210B129   322	2711010015	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.27227	-118.51262	***$0 Permit Fee due to AB 1414***PV1, NEW ROOFTOP SOLAR SYSTEM, SYSTEM SIZE IS 15.75KWac/17.75KWdc.SCOPE OF WORK INCLUDES 50 MODULES (SOLARIA POWER XT-355R-AC) WITH MICROINVERTERS (IQ7PLUS-72-ACM-US), LEADING TO A COMBINER BOX, NOTE THE MAIN SERVICE PANEL UPGRADE IS COVERED UNDER SEPERATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28211	19041-20000-12582	4433 N CARTWRIGHT AVE	91602	4	165B177   224	2423004008	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			04/08/2019 12:00:00 AM	09/08/2021 12:00:00 AM		Issued	09/08/2021 12:00:00 AM	ADDRESS	34.15127	-118.3632	Plan check for power and energy. Scope of work consists of new 800A service, 800A distribution board, 40A dsitribution board, (15) panels, (212) branch ciruits, (19) equipments, (14) smoke detectors, and T24 Total area: 6843 sq ft. B#18010-20000-05317	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28212	16041-10000-45039	1425 E 54TH ST	90011	9	108B209   413	5104009022	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	33.99403	-118.24936	PC FOR ROOF MOUNTED PV FOR 2 UNIT DWELLING 3.0KW (AC)ONE CENTRAL INVERTER  ABB-PVI 3.015 MODULES REC# ERC260PEZ.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28213	11041-20000-15872	127 S SAN VICENTE BLVD Bulletin-84TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	07/28/2011 12:00:00 AM		Permit Closed	02/15/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28214	16041-20000-44973	3376 S MOTOR AVE	90034	5	120B161   169	4314023013	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.0281	-118.40963	Plan check for installation of solar pv system, roof-mounted on a commercial building.Interconnect with a 400A MSP. 10kW ungrounded system. (36) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28215	19041-10000-25593	11662 N RICASOLI WAY	91326	12	213B109   709	2701076071	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.28404	-118.58406	Permit fee is $0.00 due to AB1414.Plan check for a PV1 11.4kW AC / 10.8KW DC roof mounted system. Scope includes (1) inverter, (30) modules and optimizers interconnecting through the main serivce panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28216	15041-10000-32171	20770 W NORDHOFF ST BLDG 4	91311	3	198B109   219	2780001***	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.23522	-118.58647	NEW FIRE ALARM SYSTEM. SCOPE INCLUDES 4 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL, AND 1 COMMUNICATION PANEL. SOME FEES PAID UNDER PCIS#15041-10000-10947.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28217	18041-10000-38984	7045 N VAN NUYS BLVD	91405	6	183B149   204	2219009025	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.19877	-118.4491	PLAN CHECK FOR ENERGY ONLY,  INTERIOR AND EXTERIOR REMODEL OF EXISTING RESTAURAN. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT3250 INDOOR AND 5105 OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28218	14041-10001-22907	12839 W SYLVAN ST	91606	2	177B161    96	2332002018	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.185	-118.41303	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: KYOCERA KD255CX-LFB3(1) POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28219	19041-20000-16327	10390 W SANTA MONICA BLVD	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.05734	-118.42365	T24 ONLY PLAN CHECK FOR EXISTING COMMERCIAL BUILDING TI. LIGHTS AND OUTLETS AND EQUIPMENTS. REPLACEMENT OF LIGHTS WITH LED MODELS.TOTAL SQUARE FOOTAGE = 8010 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28220	16041-10000-42203	535 N FAIRFAX AVE	90036	5	141B177  1012	5527020004	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.08104	-118.36162	PC FOR FIRE ALARM SYS.  IN COMMERCIAL BLDG.TOTAL OF 17 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28221	19041-10000-53377	7525 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	11/18/2020 12:00:00 AM		Permit Finaled	03/17/2022 12:00:00 AM	PIN	34.20674283	-118.48816177	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A NEW 2000 AMP SERVICE,  PANELBOARDS, NEW CIRCUITS, NEW RECEPTABLES, AND FIRE PUMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28222	12041-10000-28830	421 N HENRY FORD AVE	90744	15	030B213   392	7440001***	M3, M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2971.10	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	33.77533	-118.24134	Install 2 new x-former, feeders, and 2 MCC for an oil production field. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28223	17041-10001-33441	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	34.02557	-118.3665	11/14/2017PC FOR A LOST SET OF PLANS.PERMIT TO BE PULLED UNDER MASTER PERMIT. PLANCHECKER SEE APPLICATIONS COMMENTSPC FOR METHANE MITIGATION SYSTEM. PROVIDING NEW ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28224	12041-20001-17447	18600 W DEVONSHIRE ST Service-Building	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.25704	-118.53922	Modification to previously approved set of plans.       <<<New electrical for remodeled service building.  Plan check for T-24 and emergency lighting only.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28225	13041-10000-36018	14501 W SAN JOSE ST	91345	7	207B149   727	2648019013	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.26163	-118.44877	PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (16) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28226	16041-20000-20118	13679 W FOOTHILL BLVD	91342	7	222B157    46	2509015027	(T)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.30852	-118.43138	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. ATT DEALERSHIP STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28227	14041-10001-26344	8122 N VAN NOORD AVE	91605	2	189B161    54	2304013023	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			PC Approved	10/30/2014 12:00:00 AM	ADDRESS	34.21852	-118.41535	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE 10.71KW DC.(42) KYOCERA KD255GX(1) SOLAR SE5000A(1) SOLAR SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28228	14041-20000-02167	3440 N VISTA HAVEN ROAD	91403	4	159B145   294	2279010017	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.13328	-118.46691	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 1.7KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28229	13041-10000-06122	11932 W CHARNOCK ROAD	90066	11	114B157   419	4234018012	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.01075	-118.43066	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 5.39KW. [INVERTER: FRONIUS IG PLUS V 5.1-1] [SOLAR MODULE: TRINA TSM-245 PC/PA05]. 24 MODULES 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28230	12041-10000-30770	123 E 32ND ST	90011	9	118-5A205  76	5120001021	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.01998	-118.27069	Plan check for power and energy with new new 600 A service. Modification to separate fire alarm system from plan has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28231	13041-20000-15633	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	T24 FOR EXISTING NON HIGHRISE OFFICE BUILDING. SCOPE OF WORK: 1377 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28232	14041-20002-18621	19626 W NORDHOFF ST	91324	12	198B117   223	2783028004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.23527	-118.56116	3.21.2015 - Plan check for modifications to approved set. Update single line diagram to reflect that service distribution equipment is all new. See sheet E-3.1. ---Remodel of (E) commercial restaurant space (single-story building).  Plan check for power and energy.  Proposed occupant load of 308.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28233	19041-10000-21968	414 N EAST RUSTIC ROAD	90402	11	123B129   586	4410017010	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.03239	-118.51749	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 MODULES (Q-CELL 285) , 20 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 5.7KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28234	11041-10000-01250	4025 S DEL REY AVE #A & B	90292	11	108B149  1268	4230002005	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Closed	06/03/2016 12:00:00 AM	ADDRESS	33.99001	-118.44677	NEW RESTAURANT IN UNIT #A & B (1ST TIME TENANTS) . PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28235	15041-20000-12198	3401 N GLENDALE BLVD	90039	13	156B209   343	5435006037	[Q]C4-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			Reviewed by Supervisor	05/08/2015 12:00:00 AM	ADDRESS	34.12023	-118.25882	Plan check for service upgrade from 200A 1phase and 200A 3phase to 800A 3phase delta plus new switch gear and panel boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28236	19041-20000-38363	8534 N MARKLEIN AVE	91343	6	192B145   136	2654019007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.22557	-118.47082	PV1 PLAN CHECK FOR ADDITION OF A 3.78 KW DC/3 KW AC ROOF PV SYSTEM TO EXISTING SYSTEM. NEW TOTAL SYSTEM SIZE IS 9.45KW DC/7.2 KW AC. SCOPE OF WORK CONSISTS OF (12) PV MODULES WITH OPTIMIZERS, AND A 3 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28237	18041-20000-19103	700 S FLOWER ST Suite 2300	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is a suite in an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 6,221 sq. ft.Note: Building application has been generated under 18016-30000-13665	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28238	19041-10001-47406	11951 W PINNACLE PL	90210	2	156B165   100	2382020053	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM			PC Approved	01/28/2020 12:00:00 AM	ADDRESS	34.12513	-118.39743	EXPEDITE PER APPLICANT REQUESTNEW ROOF TOP SOLAR SYSTEM PV1 CONSIST OF 78 MODULES (LG320) WITH 78 MICROINVERTERS (IQ7PLUS). SCOPE INCLUDES NEW 200A PV SUBPANEL CONNECTED TO (E) 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28239	13041-10000-19853	400 S WESTERN AVE SUITE C1	90020	10	135B193   439	5503014023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.067	-118.30888	TENANT IMPROVEMENT FOR FIRST TIME TENANT. TITLE 24 PLAN CHECK ONLY. 3945 SQFT.  BEAUTY SALON TENANT SPACE IN 2 STORY BUILDING.  EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28240	17041-20000-42010	10350 W LOUISIANA AVE	90025	5	129B157   202	4319006035	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Expired	03/04/2024 12:00:00 AM	ADDRESS	34.0527	-118.41954	INSTALLATION OF ENERGY STORAGE SYSTEM 13.5 KWH TO EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28241	12041-10000-09833	14800 S FIGUEROA ST	90248	15	075B201   141	6129001046	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	33.89809	-118.28288	T.I. to an existing office building.  New lighting and circuits.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28242	14041-10001-28577	1011 S LONG BEACH AVE	90021	14	121-5A213  19	5130024027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	34.02837	-118.24124	PV 2 System roof mounted  103.95 KW (378) modules: Solar World Sunmodule plus SW 275 AOMO, (8) combiner box, and (4) inverters Model:  Trio-20 TL-OUTD and Trio-27.6 TL-OUTD .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28243	18041-20002-32460	10754 W WALNUT DR	91040	7	201B177   119	2542029008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.24984	-118.36466	expeditepv1install roof mounted pv system sized 12.6KW AC interconnected with msp.  battery bacvk up.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28244	13041-20000-05930	4225 S CENTRAL AVE	90011	9	114A209    92	5115019030	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Apartment			03/06/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.00695	-118.25669	Plan check for PV. 14.7kW DC. (3) 5.0kW inverters.  System is Ungrounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28245	18041-10000-41211	2830 N FLETCHER DR	90039	13	153B209  1094	5436033022	[Q]C2-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.11231	-118.24875	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28246	14041-10000-24548	1420 S BONNIE BRAE ST	90006	1	127-5A201 187	5135006005	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.04374	-118.28124	PV2 INSTALL 25.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, negatively grounded  INTERCONNECT WITH MAIN SERVICE SYSTEM.(100)MODULES: CANADIAN SOLAR 255 POLY(2) INVERTER(S): FRONIUS IG PLUS ADVANCED 11.4-1Changes on plan include updating combiner box (applicant to provide specificiation sheet to inspector) to MNPV12, provide 3/0 GEC,  indicate Fault Current:10,000 AIC, and note about fuses for ungrounded conductors.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28247	17041-20000-43821	515 S FLOWER ST 45th, 46th-Floors	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for energy only. TI to office on 45th floor and elevator lobby, office, and pantry on 46th floor. New lighting (incl. emergency) - 1,641sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28248	10041-10000-22784	1224 S BEVERWIL DR Roof	90035	5	132A167   219	4330024036	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	ADDRESS	34.0554	-118.39891	Demo the existing HVAC system and replace with new. and replace mccb board.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28249	15041-10000-15326	5957 W BARTON AVE	90038	13	144B189   910	5534025024	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Apartment			05/19/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.08813	-118.32419	NEW FIRE ALARM SYSTEM 16 UNIT APARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28250	17041-10000-12643	4821 N BAKMAN AVE	91601	2	168B173  1138	2353023***	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Issued	04/19/2017 12:00:00 AM	ADDRESS	34.15821	-118.37764	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 11,500 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28251	17041-10000-07448	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM			Verifications in Progress	10/18/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR POWER ONLY. TEMPORARY POWER FOR A CONSTRUCTION SITE. SCOPE INCLUDES A NEW 1000A 277/480V 3 PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28252	11041-20000-16850	3210 S HELMS AVE	90034	10	123B169  1779		[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	08/10/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.03079	-118.38465	ELECTRICAL PERMIT FOR T.I.Electrical plan check Ti for a retail store. EPC is for T24( 11041-20000-16786 )	N	N	Express Permit	06/10/2024 12:00:00 AM
28253	15041-20000-10220	19131 W VICTORY BLVD BLDG 7	91335	3	180B121   532	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.18674	-118.55038	PV2. ROOFMOUNTED SOLAR SYSTEM. TWO MIRRORED BUILDINGS ONE ADDRESS.  (1 OF 2 BUILDING 7 ONLY )  SYSTEM SIZE: 7KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28254	17041-10000-22789	10935 W TUXFORD ST	91352	6	198B173    86	2408039008	M2-1-CUGU, [Q]M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.23637	-118.36913	TITLE 24 ONLY SCOPE INCLUDES - REMOVE HID FIXTURES(9) AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA (6610SQ. FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28255	18041-10000-03749	10250 W SANTA MONICA BLVD #2510-LV L2	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PLAN CHECL FOR RETAIL SPACE ""ADIDAS"". (3) NEW PANELS AND (1) 75KVA XFRM. TOTAL AREA: 8,077 SQ.FT"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28256	17041-20003-14446	1302 S LA BREA AVE	90019	10	129B181   842	5070001018	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.04983	-118.34395	Revisions to approved set of plans.  Revisions to outdoor lighting system.  Delta-3 clouded revisions only.  (((Plan check for power and energy. Build out common areas (stairs, parking, etc.) for new 2-story commercial retail building over one level of subtarranean parking. 5,000A service. 107,978sqft indoor area, 30,644 outdoor area.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28257	13041-10000-18436	6605 N FALLBROOK AVE	91307	3	180B097   311	2038040015	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			07/12/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.18874	-118.62363	Installation of fire alarm system in a commercial cosmetics store.  New control panel and 8 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28258	19041-10000-07980	2211 N PANORAMA TER	90039	4	148-5A205 350	5432028002	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.1002	-118.27094	NEW ROOF MOUNTED 6.72 KW PV SYSTEM WITH 24 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28259	17041-20000-04249	1697 S PACIFIC AVE ROOFTOP	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	33.98722	-118.47211	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NEW ROOFTOP KITCHEN. PHASE 1. NOT A HIGHRISE PER APPLICANT. NEWLY CONNECTED LOAD < 400 AMPS.  332 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28260	11041-20000-11618	1032 N SWARTHMORE AVE	90272	11	129B125   839	4423016023	C2-1VL, R3P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.048	-118.52475	PLAN CHECK T24 GENERAL/EMERGENCY LIGHTING FOR EXISTING RESTAURANT TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28261	10041-20000-02685	155 N OCCIDENTAL BLVD	90026	13	138A203   347	5156018011	R3-1	Central	Westlake	Rampart Village	YES	2086.10, 2086.20	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	02/16/2010 12:00:00 AM		Permit Finaled	03/24/2010 12:00:00 AM	ADDRESS	34.0717	-118.27894	1200 S.F. REMODEL TO EXISTING 3-STORY TYPE V-A BUILDING AT BUILDING'S FIRST FLOOR. RECONFIGURATION OF CLASSROOM AREA FOR EXISTING CHILD CARE USE - NO CHANGE IN USE.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28262	10041-10000-22471	12800 W CULVER BLVD 1ST FL	90066	11	105B157   410	4221031009	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	33.98489	-118.42552	INTERIOR REMODEL OF  OFFICE SPACE. AREA OF WORK IS ON THE FIRST FLOOR.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28263	12041-10000-22995	9118 N RESEDA BLVD	91324	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.23601	-118.53588	New restarant. New service, panels, and ckts. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28264	16041-10000-42098	1001 S TOWNE AVE #201	90021	14	124-5A211 269	5132010049	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.03417	-118.24984	Plan check for Title 24 in existing space T.I. office  Bank. Total area: 2,532 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28265	10041-20000-02805	1200 W 7TH ST 1ST FLOOR	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM			PC Approved	02/17/2010 12:00:00 AM	ADDRESS	34.05136	-118.26616	T.I WORK IN OFFICE BUILDING. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY ON FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28266	12041-10000-27516	11423 W VANOWEN ST	91605	2	183B169   471	2320003025	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	34.19416	-118.38009	PV2 47.56KW FRONIUS INVERTER ROOF-MOUNT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28267	14041-20000-34877	9912 N MARNICE AVE	91042	7	201B205   400	2571016063	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.24743	-118.27179	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(26) SOLAR WORLD 275W MODULES(26) SOLAR EDGE P300 POWER OPTIMIZERS(1) SOLAR EDGE SE7600A-US INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28268	18041-10000-02129	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC for power and energy for terminal 5 of LAX. Scope includes adding new panels, lights, receptacels, equipment to kiosk/ticketing, offices, common areas and outdoor.Total area is 29666sqft. B# 17016-10000-33718Tenant Improvement to LAX Terminal 5 to include (1) installation of new storefront glazing system, (2) new public restrooms, (3) new AA and OAL offices on Arrival Level, (4) linear ticket counters at Departure Level, (5) new medical offices on Mezzanine Level, and (6) alteration and addition to existing structural.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28269	11041-10001-00239	9118 W PICO BLVD	90035	5	132B169   888	4305001004	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM			PC Info Complete	01/24/2011 12:00:00 AM	ADDRESS	34.0551	-118.39059	Ti in an existing retail store. EPC is for T24 & Energy. ( Permit was pulled under# 10041-30000-21307)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28270	15041-20001-14436	22725 W DOLOROSA ST	91367	3	174B097   769	2040019022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	34.17024	-118.62199	Expedite per applicant request*********Plan check for PV roof monted  6.8kWac system with 24 modules and 2 inverter(3.0kW and 3.8kW) and a load center connected to 200A panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28271	16041-20000-29586	20837 W BURBANK BLVD	91367	3	174B109   457	2151034072	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	09/17/2016 12:00:00 AM	ADDRESS	34.1721	-118.58669	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.55 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28272	13041-10001-35575	1001 S OLIVE ST	90015	14	127-5A209 272	5139010009	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM			PC Approved	05/13/2015 12:00:00 AM	ADDRESS	34.04228	-118.25988	05/13/15 CHANGES TO AN APPROVE SET OF PLANS. CHANGES NOTED DELTA 12 ON PLANS. (((PLAN CHECK FOR POWER AND ENERGY. NEW 7 STORY APARTMENT OVER RETAIL AND PARKING MIXED USE BUILDING. (2)  4000 AMP SERVICES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28273	18041-10000-07588	1925 S CENTURY PARK EAST SUITE 2100	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.06066	-118.41426	PC for T24 only for office TI in high rise. Installing new lights and receptacles. Total area 1588sqft. B# 18016-10000-04857.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28274	14041-20000-34909	4761 N SANTA LUCIA DR	91364	3	168B101   837	2171022044	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.15431	-118.60497	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28275	10041-20000-10273	10011 S AVALON BLVD	90003	8	091-5A207 153	6063004031	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			06/01/2010 12:00:00 AM	06/07/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	33.94523	-118.26535	TENANT IMPROVEMENT TO EXISTING RESTAURANT;Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28276	10041-10000-05739	313 S 4TH AVE BLD A	90291	11	111B141   532	4286006034	[T][Q]CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	12/13/2010 12:00:00 AM	ADDRESS	33.99722	-118.47499	CHANGE OF USE OF AN (E) OFFICE SPACE  TO STORAGE UNITS.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28277	18041-10000-46082	11911 W BRANFORD ST OFFICE-BUILD.	91352	7	204B165    72	2528007014	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Issued	12/04/2018 12:00:00 AM	ADDRESS	34.2567	-118.39186	Install new Fire sprinkling monitoring system in the FedEx Office Building, (1) FACP, (17) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28278	13041-10000-27603	1111 S HOPE ST	90015	14	127-5A207 262	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.0422	-118.26337	New service and distribution equipment for 2-story commercial building.  Existing parking space converted to retail units.  Power and energy.  Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28279	19041-20000-41756	2049 S CENTURY PARK EAST STE 1700	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	T.I TO (E) OFFICE 23,879 S.F PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28280	19041-10000-37488	8141 N SUNLAND BLVD	91352	6	192B173   793	2409001015	[Q]C2-1L-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.22	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.21873	-118.36957	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28281	15041-20000-14344	8600 N VAN NUYS BLVD	91402	6	192B149    49	2638001040	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.2263	-118.44918	Plan check for Title 24 only. Addition to 2 new restroom. Total area: 106 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28282	10041-20000-16335	14760-14764 W OXNARD ST BLDG C	91411	2	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	34.17923	-118.455	"Plan check power only. Upgrading service to 800 amp service feeding existing load. ""COMPLY WITH DEPARTMENT ORDER effective date10/27/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28283	19041-20000-12033	777 S FIGUEROA ST 45th Floor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only. Project site is the 45th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,300 sq. ft.Note: Building application has been generated under 19016-10000-08465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28284	16041-10000-34604	2183 E 11TH ST	90021	14	120A217    20	5167004027	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Info Complete	07/14/2017 12:00:00 AM	ADDRESS	34.02464	-118.23404	PC FOR POWER. Consolidatating services of 4  4 commercial building, and upgrading to 2500 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28285	18041-10002-00835	11201 N WHITE OAK AVE	91344	12	210B129   185	2711019013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.27409	-118.51991	Supplemental for relocating location of main panel and AC disconnect. Inspector to field verify that combiner box is 125A main lug only panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28286	11041-20000-10730	13422 W SATICOY ST	91605	2	186B157   183	2303024011	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	05/25/2011 12:00:00 AM		Permit Finaled	06/03/2011 12:00:00 AM	ADDRESS	34.20868	-118.4256	"PLAN CHECK T24 ENERGY FOR RESCUE CENTER DORMITORY. PERMIT FOR LIGHTING ON EXISTING CKTS AND RECEPTACLES.  ""COMPLY WITH DEPARTMENT ORDER effective date09/03/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28287	13041-10000-19791	4500 W LOS FELIZ BLVD	90027	4	150B197    21	5590003039	[Q]C4-1	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.11156	-118.28786	TENANT IMPROVEMENT. TITLE 24 PLANCHECK ONLY. ISNTALLING NEW LIGHT FIXTURES AND RELOCATING EXISITNG LIGHT FIXTURES. ONLY CLOUDED AREAS.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28288	14041-10002-02542	13455 W MAXELLA AVE # 270	90292	11	105B153    22	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM			PC Approved	08/28/2014 12:00:00 AM	ADDRESS	33.9867	-118.44159	[[[8/28/14 , CHANGES TO APPROVED SET OF PLANS. DELTA 13 CHANGES ONLY. CHANGING FEEDERS  A  AND C TO 500KCMIL ALONG WITH REDUCING THE FUSE TO 350 AMPS. ]]]]]SUPPLEMENTAL TO PERMIT #14041-10000-02542 TO CHANGE ADDRESS FROM 13450 TO 13455 W MAXELLA  AVE # 270.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28289	11041-10000-09740	3124 N SAN FERNANDO ROAD	90065	13	153A213    32	5458002014	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	PIN	34.11492636	-118.24671895	EXISTING MC DONALDS RESTAURANT.  MODIFICATION TO CEILING LIGHTS EVERYWHERE BUT THE KITCHEN.  TITLE 24 PLAN CHECK ONLY.  (Per Behrooz, outdoor lighting not included in T-24 plan check.  Will leave up to inspector whether or not T-24 is needed for the outdoor security lighting)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28290	19041-10000-16711	4326 S STEWART AVE	90066	11	108B157   455	4231014005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	33.99386	-118.42741	Plan check for a PV1 7.6KW AC / 4.7KW DC roofmounted system with (1) inveter, (1) transformer, (1) subpanel, (1) battery system, (13) modules and optimizers interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28291	18041-20000-13793	11961 W DOROTHY ST	90049	11	129B145   551	4265020012	(Q)RD2-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	07/01/2020 12:00:00 AM	ADDRESS	34.04956	-118.47003	new fire alarm system 49 devices + facp	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28292	13041-10000-07626	5560 N VINELAND AVE SUITE A	91601	2	174B173   998	2416001050	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.17168	-118.37009	T24 for a single story retail space being renovated after fire damage.  1875 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28293	17041-10000-09291	7370 W MANCHESTER AVE	90045	11	096B157  1071	4119002021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	33.95956	-118.42527	PC for energy only, outdoor Title-24. Removing HID fixtures and replacing them with new LED ones. Area: 16,425	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28294	14041-10001-03738	862 S MAIN ST	90014	14	127-5A209 294	5145015002	[Q]C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.04148	-118.25466	change of use to coffee shopplan chk is for title 24(5/6/14) Change to approved set of plans (title 24 only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28295	12041-20000-09108	16830 W VENTURA BLVD suite 400	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.15886	-118.50032	energy plan check suite 400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28296	19041-10000-51300	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	07/20/2021 12:00:00 AM		Permit Finaled	04/22/2022 12:00:00 AM	ADDRESS	34.18686	-118.37207	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A TI. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER IN AN EXISTING RETAIL SPACE (TARGET). NOTE THERE IS NO NEW SERVICE NOR NEW PANELS, JUST NEW CIRCUITS, TOTAL NEW CONNECTED LOAD IS OVER 400A. TOTAL AFFECTED AREA IS 130,736 SQFT. NOTE THERE IS TRACK LIGHTING ON FLOOR PLAN AS WELL.PER BUILDING (((TENANT IMPROVEMENT TO EXISTING TARGET. EXTERIOR SCOPE INCLUDES FURNISHING AND PAINTING UPDATES. INTERIOR SCOPE INCLUDES MINOR DEMOLITION, REPAIR/REPLACEMENT OF FINISHES, UPDATES TO FIXTURES, WALL FINISHES, FLOOR AND CEILING FINISHES, LIGHTING, PARTITIONS, ACCESSORIES, STOCK SHELVING, AND ASSOCIATED MEP WORK.19016-10000-39700))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28297	17041-20000-18681	17654 W VINCENNES ST	91325	12	198B129   155	2766001031	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.2408	-118.51956	pv1install roof mounted pv system sized 10kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28298	12041-10000-08170	23910 W STAGG ST	91304	12	189B089   446	2027040032	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Expired	05/28/2014 12:00:00 AM	ADDRESS	34.21056	-118.64968	New 14.64kw rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28299	15041-10001-04172	113 S LA BREA AVE 1st Floor	90036	5	138B181   895	5513019042	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM			PC Approved	04/16/2015 12:00:00 AM	ADDRESS	34.07317	-118.34429	CHANGES TO AN APPROVED SET O FPLANS.  CHANGES NOTED DELTA 2 DELTA 3.  CHANGES INCLUDE LIGHTING AND ENERGY CALCS.Full plan check for first time tenant, (Tenant space being developed by owner)  Emergency lighting not required due to occupant load of space - emergency lighting provided for added protection - OK per Nabil Maalouf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28300	17041-20000-21182	14353 W POLK ST	91342	7	225B149   363	2504015007	RD6-1XL-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.31126	-118.44602	Plan check for solar pv system, roof-mounted on SFD.10kW ungrounded system. (33) 330W pv modules.Each module has a 370W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28301	15041-10000-22290	18938 W SAN JOSE ST	91326	12	207B121   843	2728017011	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM			Reviewed by Supervisor	08/07/2015 12:00:00 AM	ADDRESS	34.26011	-118.54603	PV1, INSTALL 13.734 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.(42) MODULES: SUNPOWET SPR327NE-WHT(3) INVERTERS: POWER ONE PVI-5000--OUTD-US-A AND PVI-3.8-OUTD-S-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28302	18041-10000-18990	22201 W VENTURA BLVD	91364	3	174B101   498	2169026099	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.16903	-118.61081	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FXITURES WITH LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 14900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28303	15041-10000-40076	400 S WESTERN AVE # 102	90020	10	135B193   439	5503014026	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.067	-118.30888	T24 ONLY. T.I. FOR  CHANGING RETAIL TO A RESTURANT. TOTAL AREA 1054 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28304	14041-10001-16768	5314 N TOPANGA CANYON BLVD	91364	3	171B101   441	2169003045	C2-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.16641	-118.60555	CHNAGE TO APPROVED SET OF PLANS. CHANGE SERVICE TO 600A. NO CHANGE IN LOADS. CHANGE TO SERVICE ORIENTATION AND RELOCARED SOME LOADS.all changes clouded delta 5 revision	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28305	19041-20000-09693	610 S VAN NESS AVE	90005	4	135B189   927	5504018011	RD3-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			03/22/2019 12:00:00 AM			PC Info Complete	10/01/2019 12:00:00 AM	ADDRESS	34.06273	-118.3152	Two 4-story 6-unit apartment buildings with common 600A 208Y/120V 3ph-4w service. Building 1 of 2. Plan check only, permit pulled under 18041-20000-04912	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28306	14041-10000-16066	923 N COLE AVE	90038	13	144B185  1087	5533021008	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	07/02/2015 12:00:00 AM		Issued	07/02/2015 12:00:00 AM	ADDRESS	34.08776	-118.33004	PC FOR POWER AND ENEGY. TENANT IMPROVEMENT FOR MANUF. OF PRESCRIPTION PHARMACEUTICALS. TOTAL AREA 6278 SQ FT.VARIANCE FOR FIRE ALARM TO BE PULLED BEFORE THE APPROVAL.#  OF DEVICES PER APPLICANT COUNT. PLAN CHEKER VEIFY THE FEES FOR SUBMITTAL. BUILDING APP # 14041-10000-11675.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28307	17041-10000-31893	2118 W 7TH ST	90057	1	132A203    94	5141018003	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.0566	-118.27759	PC FOR RETAIL TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, EQUIPMENT, LIGHTS AND RECEPTACLES. TOTAL  AFFECTED AREA 1668 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28308	13041-10000-04249	1530 N HILLHURST AVE	90027	4	147B197   561	5542006022	[Q]C2-2D	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM			Corrections Issued	02/19/2013 12:00:00 AM	ADDRESS	34.09931	-118.28724	New fire alarm system for healthcare clinic. 77 devices and 1 panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28309	15041-10000-34250	2500 S SIGNAL ST BERTH 58	90731	15	018B201   298	7440026903		Harbor	PORT OF LOS ANGELES			2961.00	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM			PC Info Complete	01/25/2017 12:00:00 AM	ADDRESS	33.72053	-118.27222	AT BERTH 58, INSTALLATION OF SERVICE EQUIPMENT TO SUPPLY FUTURE STATE CERTIFIED MODULAR BUILDINGS AND A WAREHOUSE AT THE BERTH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28310	13041-10000-23005	5670 W WILSHIRE BLVD 1500	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/23/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	34.06222	-118.35208	PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR AN OFFICE BUILDING.  SUITE 1500. EXSITING LUMINAIRES, MODIFICATION TO WALLS, UPDATED CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28311	17041-10001-14445	10250 W SANTA MONICA BLVD	90067	5	132B157   566	4319009056	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	1st revision to approved plan on  EXISTING GELSONS MARKET: SOW, adding load (circuits) for outdoor infared heaters, as well as updating load calculation per new loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28312	19041-10000-30418	10250 W SANTA MONICA BLVD FC-7	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	ENERGY PC ONLY  FOR T.I.,  EXISTING TAKE-OUT RESTAURANT (UNIT FC-7) AT EXISTING SHOPPING-MALL FOOD COURT. AREA OF SCOPE 836SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28313	16041-20000-29504	10005 N NEVADA AVE	91311	12	204B101   648	2745005038	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Expired	10/01/2018 12:00:00 AM	ADDRESS	34.25186	-118.60959	PV1.  Install 5 kW AC roof mounted PV system.  Central inverter standard plan.  (22) modules with (1) transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28314	18041-10000-39410	2417 E WHITTIER BLVD	90023	14	124-5A221 288	5185028027	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.03426	-118.21502	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28315	19041-20000-44828	3650 S MCCLINTOCK AVE LEVEL 4-LEVEL 5	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	05/26/2020 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.02081	-118.28964	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28316	13041-10000-17693	10640 N PETIT AVE	91344	12	207B137   439	2684002901	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.26437	-118.49777	FA: REPLACE EXiSTING FIRE ALARM PANEL WITH NEW (MANUFACTURER - EST). devices: 41. panel: 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28317	19041-10000-31461	550 S HOPE ST 27TH FLR	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.04989	-118.25574	T-24 PLAN CHECK FOR A TI TO AN EXISTING OFFICE SPACE IN A HIGH RISE (27TH FLOOR). SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10,643 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28318	12041-10000-29379	22742 W CRISWELL ST	91307	3	180B097   273	2038022029	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	03/05/2013 12:00:00 AM	ADDRESS	34.19052	-118.62296	PV1 PLAN CHECK ROOF MOUNTED PHOTOVOLTAIC SYSTEM INSTALLATION.  SYSTEM SIZE IS 8.14 KW. TWO STRINGS WITH 37 MODULES AND USING SOLAREDGE TRANSFORMERLESS INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28319	16041-20001-21228	10348 W DIAMOND ST LOT 15	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28320	15041-10001-08414	3655 S GRAND AVE	90007	9	118-5A203 278	5122023028	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM			PC Approved	01/24/2017 12:00:00 AM	ADDRESS	34.01726	-118.27819	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES FOR A RESTUARANT IN A FOOD COURT. TOTAL AFFECTED AREA IS 969 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28321	19041-10000-53299	5508 N WOODMAN AVE	91401	4	174B157   812	2344001029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	01/27/2020 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.17069	-118.43104	[EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 11.7KW DC/ 10KW AC (10.483KW CEC-AC), 39 POWER OPTIMIZERS (P320), 1 CENTRAL INVERTER (SE10000H-US) , AND A EXISTING 200A MAIN SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28322	15041-20001-28084	19945 W LANARK ST	91306	3	189B113    60	2106031025	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.21812	-118.5682	Plan check per inspector request based on electrical plan check requirement of an 11.4 kW rated PV system.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28323	12041-10002-09218	735 S BROADWAY	90014	14	127-5A209  71	5144014031	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			12/07/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.04448	-118.2543	Plan check power and energy for new 6 live-work units in an existing building. Site locate in methane buffer zone. New 1000A service. Modification to seperate fire alarm plans have been filed. Commercial spaces future.((((((  12-07-12  change of floor plan added receptacle , switch gear relocation. no load change.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28324	16041-20000-07540	140 S RENO ST	90057	13	138A201   373	5155004025	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.07028	-118.28178	$0 permit fee is due to State Senate Bill SB 1222PV2. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM 1 SIZE: 152.6 KW.TOTAL SYSTEM SIZE: 234 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28325	14041-20000-17712	2415 E 15TH ST BLDG A	90021	14	120A217   231	5168010919	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.02106	-118.22952	First-time tenant for 2-story office and warehouse.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28326	17041-20001-44707	10677 N EL DORADO AVE	91331	7	207B157   634	2620006008	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.26408	-118.42306	Expedited plan check fee. PV1.  Installing 2.95 kW DC roof mounted grid tied PV system.  (E) PV system previously permitted on site.  Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28327	16041-20000-17070	2929 S QUEENSBURY DR	90064	5	126B161   502	4316001005	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.03857	-118.40617	Plan check only  for PV roof mounted system. System size: 7.6kW with 27 modules and 1 inverter(7.6kW)Inspector request for plan check due to inverter is in garage closet and the conductor is running in the attic.Note: Permitted application Number: 16041-90000-11180	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28328	17041-10000-13940	655 W 106TH ST	90044	8	090A201   287	6061018006	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	33.94003	-118.28654	PV INSTALLATION OF 3.84 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOME. 12 AC MODULESNote: Permit is paid under PCIS#17041-90000-11830	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28329	16041-10000-41804	927 E 25TH ST	90011	9	118-5A209  30	5131021009	R3-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.02048	-118.25599	PV INSTALL NEW 2.65 KW DC/2.5281 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(10) MODULES: AXITEC AXIPOWER AC-265P/156-60S(1) INVERTER: FRONIUS GALVO 3.1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28330	18041-10000-34227	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-2D-CPIO	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.76597	-118.28407	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28331	13041-10000-09751	9301 N TAMPA AVE SPACE 28A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM			Corrections Issued	04/16/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	13041-10000-09751 T24 FOR EXISTING RETAIL SPACE. 834 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28332	10041-10000-11648	205 W WORLD WAY WEST	90045	11	090B165    62	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/18/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Expired	03/21/2013 12:00:00 AM	PIN	33.9448278	-118.40237129	new interim maintenace building for los angeles world airport	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28333	18041-10000-39548	3115 W 3RD ST	90020	13	136-5A201 127	5501019001	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.06882	-118.2848	NEW FIRE ALARM SYSTEM IN AN APARTMENT BUILDING. TOTAL 110 FA DEVICES AND 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28334	16041-20000-38320	1972 N RONDA DR	90032	14	135A231    53	5215025008	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	Yes	2014.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.06549	-118.18433	PV1.  Install 5.1 kW DC roof mounted grid-tied PV system.  (17) modules with Enphase M250 microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28335	15041-20000-14386	5422 N WOODMAN AVE	91401	4	174B157  1086	2344002007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.1692	-118.43104	Plan check for PV roof mounted system 3.8kWac with 13 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28336	12041-20000-04834	20342 W DELITA DR	91364	3	171B109   345	2166037021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.16226	-118.57774	15.2 kw roof mounted PV system for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28337	18041-20000-24978	15875 W MCQUEEN ST	91342	7	228B141   269	2603018019	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.32045	-118.47845	Plan check for PV roof mounted system, system size: 10.2kW AC CEC with 38 modules and 2 inveters(5.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28338	14041-10000-12728	12178 W VENTURA BLVD	91604	2	162B165   199	2369004045	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.14309	-118.3978	PERMIT ON REPLACING RECEPTACLES IS ISSUED PER APPLICANT REQUEST.T.I remodel of existing retail space and electrical work	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28339	19041-10000-31755	450 S WESTERN AVE #209	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.06562	-118.30887	Energy plan check for a retail T.I. Scope includes new lighting and equipment with a total lighting area of 762-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28340	19041-20000-40380	18445 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28341	13041-10000-21300	6624 W ROMAINE ST	90038	4	144B185   969	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.08881	-118.334	NEW BUILDING, CORE & SHELL , 8 STORIES PARKING, 199740 SF, PC IS FOR POWER AND ENERGY. 1 PLAN WILL BE SUBMITTED FOR 3 BUILDINGS; THIS IS BUILDING # 1 OF 3. SWITCHBOARD SECTIONS NEEDS TO BE CHARGED, ELEVATION DIAGRAM IS MISSING. LOCATION IS IN METHANE ZONE .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28342	11041-10000-25075	17555 W SATICOY ST	91325	12	186B129  1303	2202002038	RS-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Expired	12/17/2013 12:00:00 AM	ADDRESS	34.20857	-118.5161	PLAN CHECK 6.10KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28343	12041-20000-10846	8701 S BELLANCA AVE	90045	11	096B169   683	4125016031	MR1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	05/31/2012 12:00:00 AM	ADDRESS	33.95858	-118.38067	Ti for existing office remodel. Plan check for energy. 449 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28344	12041-10000-11614	13603 W MARINA POINTE DR	90292	11	105B153    74	4229003066	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Apartment			05/21/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	33.98559	-118.44433	Plan check T24 outdoor lighting for Building C and main entrance of Building B. Site located in methane zone. No installation in hazardous area. Permit for new fixtures on existing branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28345	19041-20000-52872	8500 N FALLBROOK AVE	91304	12	192B097     2	2004025001	(T)(Q)R1-1, (T)(Q)RD3-1, (T)(Q)RE11-1, (T)OS-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.22475	-118.6235	T24 PLAN CHECK FOR LIGHTS ONLY, TOTAL SQUARE FOOTAGE = 2730 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28346	16041-20000-05074	3243 S LA CIENEGA BLVD	90016	10	123B173  1679	4205035002	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.02892	-118.3739	Plan check for Title 24 only outdoor area stacker parking space. Total area: 9,455 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28347	13041-10000-35774	818 W 7TH ST #700	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.04895	-118.25943	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT. 7TH FLOOR. SUITE 700. 12,500 SQ FT. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28348	12041-10000-15287	9301 N TAMPA AVE #103	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I. to an existing restaurant space at the Northridge Mall in the food court Space #103.  Load is 176 A and occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28349	15041-20000-28467	17437 W MARILLA ST	91325	12	201B129   207	2755012029	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.24782	-118.51547	Plan check for PV roof mounted system. System size: 10kW with 36 modules and 1 inverter(10.0kW) connected to 400A main panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28350	16041-20000-14642	16554-16556 W ARMINTA ST	91406	6	189B137    45	2205009047	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.21471	-118.49408	Plan check for a PV2 roof-mounted PV Feed-In Tariff system. System size is 72 kWac and consists of (6) inverters, (264) modules, and (1) load center.$0 permit fee is due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28351	15041-20000-06666	17965 W MAYERLING ST	91344		216B129   169	2601029015							Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM	ADDRESS	34.28804	-118.52425	Plan check for PV roof mounted 1.1 kW with centural inverter 50 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28352	16041-10000-27167	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.03396	-118.24117	Tenant Improvement. PC for energy only to a 4 story commerical building. Scope of work is being done on 2nd floor. First floor lights are all existing to remain. Installing new lighting and power. Total sqft = 4178Building app # 16016-10000-06970.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28353	16041-20000-21100	17500 W DONMETZ ST	91344	12	210B129   171	2711013020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.27431	-118.51554	Plan check for PV roof mounted system. System size: 10.5kW with 42 modules and 42 microinverters Enphase.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28354	16041-10000-34764	701 S VERMONT AVE	90005	10	132B197   227	5094011024	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM			PC Approved	09/30/2016 12:00:00 AM	ADDRESS	34.05952	-118.2918	PC FOR T24 ENERGY ONLY. EXTENSION OF JUICE SHOP TO NEIGHBORING TENANT SPACE. NEW LIGHTING LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28355	17041-10000-14516	1318 N LYMAN PL	90027	13	147B197   960	5542012005	R4-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.09638	-118.28837	Plan check for power and Title 24.  New 5 story parking structure with two basement parking levels.  New 25 HP fire pump.  Space for future generator (under phase II).  New 2,000 amp 480/277 volt service.  Total area = 182,054 (indoor) + 21,947 sq. ft. (outdoor).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28356	10041-10014-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN REVIEW IS FOR THE ADDITION OF EXIT SIGNS -47 EA TOTAL - ON CORE  LEVEL 01 THRU LEVEL 6  AT TBIT AND FOR THE RELOCATION OF 10 EXIT SIGNS ON CONCOURSE  LEVEL 04 PER LAFD REQUEST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28357	16041-20000-11128	600 E 4TH ST	90013	14	127-5A215 151	5147010015	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Info Complete	04/12/2016 12:00:00 AM	ADDRESS	34.04421	-118.24072	Plan check for power and energy. CHANGE OF USE & MAJOR  REMODEL OF (E) MIXED-USE COMMERCIAL (WHAREHOUSE, RESTAURANT&RESIDENTIAL UNITS) TO BANQUET HALL. New 800A service. Project is located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28358	19041-10000-11862	1040 N LAS PALMAS AVE STAGE 7	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 7	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28359	13041-10000-19640	4311 S LINCOLN BLVD	90292	11	105B153    87	4229018032	C4(OX)-2D, [Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	33.98535	-118.44358	FULL PLAN CHECK. POWER AND ENERGY. NEW LOADING OF EXISTING PANELS + 1 NEW PANEL. RALPHS SUPERMARKET. 38007SQFT.  SINGLE STORY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28360	12041-10000-21349	15840 W HART ST	91406	6	183B141   460	2224029024	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.19743	-118.47861	INSTALLATION OF A ROOF-MOUNTED  7.848KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28361	13041-10000-09144	20435 W SORRENTO LANE BUILDING B	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.27842	-118.57885	INSTALLATION OF NEW FIRE ALARM SYSTEM. TOTAL NUMBER OF DEVICES 135. 3-STORIES HIGH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28362	13041-10001-35730	888 S HOPE ST	90017	14	129A209   239	5144020020	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			PC Info Complete	08/28/2014 12:00:00 AM	ADDRESS	34.0452	-118.25996	((((7/10/2014  Changes made to approved set.  Changes made to fire pump and lighting locations in stairwell))) plan was aporoved as a counter job with application was taken in as a regular plan. permit is existing as a plan check only.PLAN CHECK FOR POWER AND ENERGY FOR NEW PARKING STRUCTURE. SUBMITTAL FOR PARKING AND RETAIL. BUILDING # 13010-10001-01140	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28363	17041-20001-28602	11433 W ALBERS ST	91601	2	174B169  1079	2350007049	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.17056	-118.38016	Revisions to approved set.  Additional sump and sewage ejector pumps, revised HVAC loads.  Delta B revisions only.  (((Plan check for power and energy. (N) 59-unit, 4-story apartment building over 1-Level of subterranean garage. 1600A 120/208V 3ph 4w service. 26 typical units. T24 area: indoor-25,039sqft; outdoor-3,468sqft. Fire alarm variance on file.Building permit # 16010-20000-05094)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28364	19041-20000-33536	23416 W CANZONET ST	91367	3	171B093   306	2044019005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.16629	-118.63699	PV1. INSTALL 15.84 KW DC ROOF MOUNTED SOLAR SYSTEM WITH (44) MODULES AND MICROINVERTERS (IQ7PLUS-72-2-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28365	13041-10000-15693	1900 N SUNSET PLAZA DR	90069	5	147B169    37	5558014006	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00, 1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.10266	-118.38231	PV1 ROOF MOUNTED SOLAR INSTALLATION IN A SIGNLE FAMILY DWELLING. TWO INVERTERS ON A NONSTANDARD PV PLAN. SYSTEM SIZE IS 9.81 KW USING 46 MODULES IN 4 STRINGS. [MODULE: SUNTECH # STP245 |||| INVERTER: SUNNYBOY 60000-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28366	16041-30000-16377	22260 W CAPULIN CT	91364	3	168B101    75	2170007033	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.16002	-118.61171	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (30) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28367	11041-10002-21950	1480 W ANAHEIM ST	90744	15	030B197    12	7412022010		Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM			PC Approved	11/01/2012 12:00:00 AM	ADDRESS	33.77868	-118.28292	Plan check to verify available fault current AIC for distribution and address. Medium voltage, addition of new skid, new pumps, and other equipment , non classified area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28368	16041-20001-29513	933 N STONEHILL LANE	90049	11	138B141   155	4493022021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.07584	-118.48477	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28369	17041-20000-20273	8320 W 3RD ST	90048	5	138B173   889	5511031035	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.07252	-118.37079	PLANCHECK OF T24 ENERGY. CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28370	14041-10000-07248	4150 W PICO BLVD	90019	10	129B189   965	5072005010	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.04756	-118.32583	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT & CHANGE OF USE FROM RETAIL STORE TO AUTO REPAIR GARAGE.  NON HAZARDOUS PER APPLICANT. 1530 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28371	17041-10001-26270	1016 N ALVARADO ST	90026	13	139-5A207 154	5404003024	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	34.07681	-118.26375	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO EMERGENCY FIXURE LAYOUT AND REMOVAL OF AN O.S. NO OTHER CHANGES. PROVIDED UPDATED LIGHTING PLAN AND EGRESS PHOTOMETRIC. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28372	16041-20001-23165	210 N LADERA DR	90210	5	141B157    93	4358006046	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Expired	09/22/2023 12:00:00 AM	ADDRESS	34.08184	-118.4235	[[5/24/17 CHANGES TO APPROVED SET. SERVICE UPGRADE TO 3 PHASE 800 AMPS . ADDITIONAL LOADS WERE ADDED]]]Plan check for SFD(Single Family Residence) power only replace existing 600A main switch gear with a new switch gears(2) at 600A with associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28373	16041-10000-27896	20101 S HAMILTON AVE STE 100	90502	15	054B197   127	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	33.84769	-118.28637	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR SUITE 100. TOTAL AFFECTED AREA IS 3860 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28374	15041-20000-03725	13026 W GOLETA ST	91331	7	204B161   329	2623015004	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.25561	-118.41636	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28375	18041-10001-09229	1413 W 58TH PL	90047	8	108B193  1438	6002004014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Expired	10/18/2023 12:00:00 AM	ADDRESS	33.98846	-118.30076	PC FOR CHANGES TO EXPRESS PERMIT FOR PV ON SLD TO REFLECT FIELD CHANGES. SCOPE INCLUDES NEW DISTRIBUITION PANEL AND ADDITIONAL DICONNECTS. ADDITIONAL PERMIT FOR THE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28376	15041-20000-07989	250 N DELFERN DR	90077	5	141B157    79	4358005019	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.08284	-118.4305	Plan check for a new single family dwelling.  Service size = 800 A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28377	11041-10000-06148	139 N WESTERN AVE BLDG B	90004	4	138B193   868	5517003002	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Issued	04/26/2011 12:00:00 AM	ADDRESS	34.0741	-118.3095	"ORIGINALLY , A SERVICE EXISTED TO SUPPLY BUILDING  ""B"" ; SERVICE IS UPGRADED TO SUPPLY BUILDING B AND AN EXISTING BUILDING CONVERTED TO COMMERCIAL USE. TENANT SPACE # 106 WILL BE A RESTAURANT WITH A 2ND FL EXTENDED ABOVE TENANT SPACE # 107 THERE ARE 6 MORE TENANT SPACES IN BUILDING A- TENANT 201 ABOVE TENANT 101"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28378	14041-20000-02466	601 S FIGUEROA ST #3800	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.05076	-118.25881	PC FOR T24 ENERGY ONLY. OFFICE TI WITH NEW LIGHTING. TOTAL AREA 7100 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28379	13041-20000-07097	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	07/23/2013 12:00:00 AM	ADDRESS	34.21302	-118.45859	Plan check for energy and emergency lighting. Addition of a Starbucks kiosk inside Target.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28380	12041-10000-20453	15301 W VENTURA BLVD Ste. P-16	91403	5	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.15411	-118.46654	PLAN CHECK POWER AND ENERGY FOR NEW RESTAURANT IN EXISTING BUILDING (BUFFALO WILD WINGS - UNIT P-16)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28381	18041-20001-03184	5636 W BRIARCLIFF ROAD	90068	4	151-5A193 279	5587021013	RE11-1D	Central	Hollywood	Hollywood United	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/26/2018 12:00:00 AM	ADDRESS	34.10883	-118.31319	03/30/2018 Changes to an approved set of plans. All changes have been clouded. AC PV module count has been reduced to (24) modules and PV system interconnection has changed to reflect field conditions. *****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 9.3 kWac and consists of (29) AC PV modules and (1) load center. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28382	13041-20000-14519	1632 S SHELL AVE	90291	11	108B145  1086	4241020019	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	33.99157	-118.46119	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.24KW. 15 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28383	11041-20000-00813	2707 W BEVERLY BLVD	90026	13	136-5A203  19	5156020019	C2-1	Central	Westlake	Rampart Village	YES	2086.20	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	PIN	34.07021195	-118.27775843	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28384	11041-20000-01294	879 W 190TH ST	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	33.85951	-118.28963	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28385	18041-10000-37670	1533 N SCHRADER BLVD Hygiene-Bldg	90028	13	147A187    32	5547018901	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.09901	-118.33257	New emergency temporary shelter for the homeless consisting of two separate state certified modular buildings-Admin Bldg; Hygiene Bldg  and newly constructed building -Membrane Bldg;This application is for the the wiring from the swbd to this building. Branch circuits inside this building will be part of the state certification.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28386	17041-20001-11723	21820 W BURBANK BLVD STE 175	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM			PC Approved	04/18/2017 12:00:00 AM	ADDRESS	34.17228	-118.6032	Revisions to approved plans - approval is for clouded changes only.  Removal of controlled receptacles from floor plan designs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28387	17041-10000-06879	5212 W ADAMS BLVD	90016	10	123B177  1018	5049019026	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.03225	-118.35598	PC for outdoor title 24 only. Removing HID fixutres with new LED fixutres. Area: 45200	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28388	15041-10007-36118	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	34.24205	-118.59773	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO REFLECT AS BUILT CONDITIONS.  ALL CHANGES ARE CLOUDED DELTA 4. PLAN CHECK PER INSPECTOR'S REQUEST. NOTE: PERMIT IS PAID UNDER MASTER APPLICATION 15041-10000-36118	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28389	18041-20001-12796	12202 W VENTURA BLVD	91604	2	162B165   218	2369004038	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM			PC Approved	08/10/2018 12:00:00 AM	ADDRESS	34.14304	-118.39861	08-10-2018 changes to an approved set of plan. Changes include relocating loads from panel B to A and reduction of feeder size. Changes has been clouded as delta 6. Plan check only. Permit covered under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28390	19041-10000-35788	10340 N SEPULVEDA BLVD	91345	7	204B145   201	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Issued	11/12/2019 12:00:00 AM	ADDRESS	34.2586	-118.46705	ENERGY PC ONLY FOR RELOCATE EXISTING FIXTURES INSIDE EXISTING TARGET STORE. AREA OF SCOPE 2843SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28391	14041-20001-35605	5700 W WILSHIRE BLVD suite 120	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	3.3.2015 - Changes to approved set. Areas where work is being done have been altered, now 6,048 sqft, new lighting fixture counts. Redo title 24 plan check.[Plan check for Title 24 energy. Offices no change in occupancy. TI. Suite 120. Sqft 6504. Newly connected load less than 400 A.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28392	18041-10001-40393	4950 N LAUREL CANYON BLVD EV2	91607	2	171B165  1126	2355009061	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			12/05/2018 12:00:00 AM			PC Approved	12/05/2018 12:00:00 AM	ADDRESS	34.16075	-118.39629	PC FOR POWER ONLY. SCOPE INCLUDES FOR INSTALLING (22) EV CHARGERS, TWO 45KVA TRANSFORMERS,  AND TWO 150A PANELBOARDS. PERMIT HAS BEEN OBTAINED UNDER 18041-10000-40393	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28393	18041-20001-45410	4510 N RADFORD AVE	91607	2	165B169    21	2364006022	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.15248	-118.39193	12/10/2018 Changes to an approved set of plans. Battery back-up system has been removed. PV system has remained the same.*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 16.07 kWdc/15.05 kWac-CEC and consists of (2) inverters, (51) modules, (2) load centers, and (2) back-up batteries.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28394	13041-10000-17998	151 W 25TH ST	90007	9	121-5A205 160	5126035017	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			Verifications in Progress	10/21/2013 12:00:00 AM	ADDRESS	34.02666	-118.26953	UNAPPROVED. NO BUG RATINGSpermit to be pulled at EPC counter only. pc for energy only. less than 400A connected load. methane zone but no underground work per applicant. self powered exit signs.  changes on plan: removed all emergency lights since occupant load, as determined by engineer, does not require it.new 9500 SQ.FT.  2-STORY MASONRY WAREHOUSE (13010-20000-01580)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28395	18041-20001-43440	2415 N GREEN VIEW PL	90046	4	153B169   248	5564033020	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.11635	-118.38911	Revision to approved set of plans.  Change of location of ESS and additional 30A fused disconnect.(((Installation of 13.5 kWh energy storage system and associated distribution.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28396	19041-10000-49521	22134 W SHERMAN WAY	91303	3	183B101   110	2024012004	C1-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.20073	-118.60924	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFITS KITS (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28397	19041-20001-52891	12717 W GAULT ST	91605	2	183B161   182	2324019017	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	01/03/2020 12:00:00 AM	ADDRESS	34.19946	-118.41004	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 23.12 KW DC/20.351 KW AC CEC. SOCPE OF WORK CONSISTS OF (68) PV MODULES WITH (2) INVERTERS (11.4 KW) (10 KW) AND A 125A LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28398	15041-10000-01878	921 S CROCKER ST #C-8 & C-9	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	TI for retail store.  Plan check for T-24 only. Total area: 3115 SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28399	19041-10000-00015	12500 W MAGNOLIA BLVD	91607	2	171B165   533	2357006017	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM			PC Approved	01/02/2019 12:00:00 AM	ADDRESS	34.16472	-118.4055	ENERGY PLAN CHECK FOR A CHANGE OF USE FROM OFFICE TO RESTAURANT; SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 1900-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28400	16041-20001-07736	7858 N LANKERSHIM BLVD	91605	6	189B169   482	2311015001	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.21372	-118.38757	(12/16/2016)changes to an approved set of plans.  changes noted delta 1.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28401	18041-10000-36431	17400 W VICTORY BLVD	91406	6	177B129     8	2229033900	A2-1-RIO, OS-1XL-RIO	South Valley	Reseda - West Van Nuys	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.18631	-118.51407	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28402	14041-20000-31637	22454 W SCHOOLCRAFT ST	91307	12	183B101   576	2024028010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.19588	-118.6166	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW.(48) KYOCERA #KD255GX(2) ABB PVI-5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28403	13041-10001-28604	8055 W 3RD ST	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM			PC Approved	10/01/2014 12:00:00 AM	ADDRESS	34.07218	-118.36515	supplemental for the addition of (1) methane sensor in suite #8055.New Methane Mitigation Control System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28404	18041-10003-35822	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	DELTA CHANGES TO ORIGINAL PERMITTED SET OF PLANS: ORIGINAL PLANS SHOWED A NEW SERVICE WITH LOADS; THIS SERVICE WILL BE IDENTIFY  AS A FUTURE  INSTALLATION AND THE LOADS SUPPLIED FROM A NEW FEEDER FROM MSA.  (((((((((DESIGN BUILD. Full plan check for a office/warehouse TI. Scope include new lighting, and equipment with a total area of 312,000-SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28405	14041-20000-17788	429 N LARCHMONT BLVD	90004	4	138B189    49	5523020033	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.07833	-118.32383	PV1Microinverter standard plan.Install roof-mounted solar array on SFD. System size: 4.968kW(23) EnPhase M215s with IG micro inverters(23) Solar World SW270 Mono Black pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28406	13041-10001-32954	12951 W HARDING ST	91342	7	222B161   136	2512029081	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.30761	-118.41514	Expedited RSES plan check per applicant request.[][]PV1, Install  5 kw DC roof-mounted solar array,   interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 20 modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28407	16041-20000-24581	18123 W TOPHAM ST	91335	3	177B125  1042	2124015048	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.18074	-118.52816	PV1. ROOMFOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28408	16041-10000-18613	1530 S OCEAN FRONT WALK	90291	11	106-5A143  65	4226001903	OS-1XL-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Issued	09/08/2016 12:00:00 AM	ADDRESS	33.98684	-118.47372	EXISTING OCEAN FRONT. NEW SERVICE FOR STREET VENDORS AND LANDSCAPE LIGHITNG. NEW PANEL FOR FUTURE USE. NO TITLE T24 - EXEMPT. PC FOR POWER ONLY. 1000A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28409	19041-20000-03176	5698 1/2 E VIA MARISOL	90042	1	150A229   323	5492005020	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	NO	1837.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.1041	-118.19204	Plan check for PV roof mounted system, system size: 5.28KW DC, 5.0KW AC with 17 PV Modules and 1 inverter(5.0KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28410	14041-10000-16741	145 S FAIRFAX AVE	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	PIN	34.07292853	-118.36175524	T24. TI. NO CHANGE OF USE.OFFICE. TOTAL AREA 3650 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28411	16041-10000-23715	555 S MATEO ST Bldg 1,2,3	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.03943	-118.23302	Installation of a new fire alarm system to a commercial site. Total of 3 buildings: Building 1 is an existing single story, Building 2: New 3-story building. Building 3: New single story. All under same permit. (1) Fire alarm panel, (3) control panels, (2) communication panels, and (147) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28412	11041-10000-00262	7900 S LOYOLA BLVD	90045	11	099B161     3	4113001004		West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2764.00, 2765.00	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	04/08/2011 12:00:00 AM	ADDRESS	33.96604	-118.41693	"TI REMODEL IN ""PEREIRA HALL SOUTH"" BUILDING IN LOYOLA MARYMOUNT UNIVERSITY. (PhaseII of the project). PLAN CHECK FOR POWER AND ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28413	16041-10001-00798	232 E 2ND ST	90012	14	129A213    28	5161024034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Info Complete	08/03/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	CHANGE TO APPROVED SET. CHANGES ARE UNDER DELTA 3. CHANGES HAVE REDUCED OVERALL LOAD CALC.  NO CHANGES TO LIGHTING. PERMIT EXISTS UNDER MASTER APPLICATION.****************************//////////************************************************Plan check for 1st time tenant for Starbucks Coffee in mix use building(Multi units dwelling and commercial). Total area: 1,827 sq ft.Building Application #: 15016-10000-28333	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28414	18041-20000-42540	14620 W HIAWATHA ST	91345	7	204B149    33	2648013027	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.25985	-118.45032	Plan check for a PV1 roof-mounted PV system. System size is 2.9 kWdc/3 kWac and consists of (1) inverter and (10) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28415	14041-10000-22089	3550 W 6TH ST	90005	10	135B197  1072	5502031014	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.06341	-118.30006	PLANCHECK FOR POWER AND ENERGY.  CONVERSION OF AN EXISTING 5 STORY OFFICE/PARKING BUILDING TO ADAPTIVE RE-USE (89 UNITS W/ STUDIO, 1, 2 AND 3 BEDROOM UNITS ALONG WITH 3 LIVE/WORK UNITS). THE EXISTING PARKING ON THE 1ST FLOOR TO REMAIN, FLOORS 2-5 ARE CONVERTED TO 92 UNITS.  EXISITING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28416	17041-10000-42176	1346 W 58TH ST	90037	9	108B197  1359	5002015001	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			Corrections Issued	11/29/2017 12:00:00 AM	ADDRESS	33.98977	-118.29964	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH A TESLA POWERWALL. TOTAL SYSTEM SIZE IS 3.6KWac.(17)MODULES-TRINA SOLAR #TSM-300DD05A.18(1)5.8KVA 1.5KWH AC POWERWALL(1)INVERTER-PVI-3.6-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28417	15041-10000-37283	11309-11315 S ATHENS WAY	90061	8	087A203   242	6074024035	C2-1VL	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	33.93166	-118.27905	PC FOR ENERGY. NEW 3-STORY BUILDING WITH 3 RETAIL SPACES AND 9 APARTMENT UNITS. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES TOTAL AREA 1384 SQ FT CONDITIONED FOR RETAIL + 4321 SQ UNCONDITIONED FOR PARKING GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28418	19041-20000-27106	4451 N VANCEBORO CT	91364	3	166-5A111  43	2174013029	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Issued	07/16/2019 12:00:00 AM	ADDRESS	34.15163	-118.58296	Paln check for Energy Storage System installed in to existing PV system. Energy storage size: 13.5KWh with 1 Tesla Power Wall, 1 Gate Way and new sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28419	13041-10000-08105	1217 W TEMPLE ST	90026	1	135A211    61	5160023004	CW	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	04/12/2013 12:00:00 AM	ADDRESS	34.06535	-118.25304	T24 FOR CHANGE OF USE FROM FLOWER SHOP TO RESTUARANT. 1950 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28420	15041-20001-01212	10342 N LINDLEY AVE	91325	12	204B125   120	2731010016	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	PIN	34.25819985	-118.52695571	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20.0KW INTERCONNECTED WITH MSP.THIS IS 2ND  PV DESIGN OF TWO.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28421	19041-20001-36625	10575 W VINEDALE ST	91352	7	195B177   411	2404004015	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.22873	-118.36143	CHANGES TO ONLINE PERMITED PV SYSTEM ADD (2) NEW PV MODULES.ONLINE PC #: 19041-90000-36625<<<Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28422	16041-10000-17544	6256 N TOPANGA CANYON BLVD #1350	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Issued	07/20/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	Tenant improvement of existing retail space. FIRST TIME TENANT. FULL PLAN CHECK. POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28423	17041-20000-40462	4100 S GLENCOE AVE	90292	11	108B153  1063	4230006003	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	33.98982	-118.44256	Plan check for energy only. TI to existing office. New lighting (incl. emergency) - 7,665sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28424	18041-20001-29928	24203 S STERLING RANCH ROAD	91304	12	192B089   184	2017038016	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.21965	-118.65411	change of address	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28425	11041-10000-23846	920 W BLOOM WALK	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.01996	-118.28938	P/check for T-24 lighting compliance including egress and/or exit sign lighting.(INTERIOR NON-STRUCTURAL T.I. IN EXISTING OFFICE (~ 1481 S.F.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28426	13041-20000-35916	6900 N RANCHITO AVE	91405	2	183B153   882	2216019022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Expired	02/02/2016 12:00:00 AM	ADDRESS	34.1959	-118.43552	PV1 SINGLE FAMILY DWELING. TOTAL SYSTEM SIZE 9KW AC USING TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. WITH POWER OPTMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28427	13041-10000-35878	947 S TIVERTON AVE 12F,13F	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			12/24/2013 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.06246	-118.44303	pc for power and energy. assisted-living TI EXIST APT UNITS ON ENITRE 10TH AND 11TH FLOORS.4TH AND 5TH FLOOR PC # 13041-10000-356426TH AND 7TH FLOOR PC # 13041-10000-358628TH AND 9TH FLOOR PC # 13041-10000-3587210TH AND 11TH FLOOR PC # 13041-10000-35875ADDITION OF GENERATORS AND PANELS  PC # 13041-10000-35626	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28428	17041-20000-41920	6111 S GRAMERCY PL	90047	8	105B189   843	6001012028	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.98411	-118.31358	PLANCHECK FOR POWER AND ENERGY.  T. I. TO (E) 2ND FLR SPACEBUILDING PERMIT # 17016-20000-34392	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28429	16041-20000-12151	21600 W OXNARD ST Suite 1900	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 only. Project site is an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 7,793 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28430	14041-10000-08561	1015 S CROCKER ST # Q23	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	Title 24 only. Remove HID light fixtures and replace with new fluorescent fixtures. Total area 3225 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28431	19041-20000-26786	70 S FREMONT PL	90005	4	132B185   361	5090020014	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.05874	-118.32708	Plan check for PV roof mounted system, PV System size: 10.56KW DC, 10KW AC with 32 PV Modules and 1 inverter(10KW) connected existing 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28432	14041-20001-10925	9549 S DEFIANCE AVE	90002	15	093A213   229	6048021032	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	33.94918	-118.24539	Restamp for lost plans.  Plan check only.*****Previous Work Description*****PV1.  mounted-roof system with (16) micro inverter enphase M215-60-2LL-S22, and (16) module of Canadian solar CS6P 250P, 250 watt each. total AC: 3.44kw.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28433	16041-10000-30867	5132 N EL RIO AVE	90041	14	163-5A221 309	5671016019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	11/19/2016 12:00:00 AM	ADDRESS	34.1405	-118.21606	Fees are $0 Due to senate bill 1222.(((((PC for new rooftop PV solar system with 41 modules, 1 SB7700TL inverter rated at 7680W,1 SB5000TL inveter rated at 5000W and 1 load center. Installing modules in front of housewith main panel located in backhouse.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28434	13041-20000-00256	879 W 190TH ST # 380	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			01/04/2013 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	33.85951	-118.28963	Install receptacles and relocate in office area.  Plan check for T-24 lighting only.  TENANT IMPROVEMENT WORK ON 1,700 SQ.FT. OF 18,450 SQ.FT. TOTAL FLOOR AREA: NEW NON-LOAD BEARINGS, NEW PARTIAL CEILING GRID, TILES AND RELOCATE LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28435	19041-10000-18842	6255 W SUNSET BLVD SUITE 100	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM			PC Info Complete	06/04/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING BANK CENTER. TOTAL EFFECTED AREA 2805 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28436	17041-20001-30856	879 W 190TH ST 1020	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	33.85951	-118.28963	Commercial tenant improvement in (E) high-rise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28437	13041-10000-19659	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			08/05/2013 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.09918	-118.32644	POWER AND ENERGY PLAN CHECK 287 UNIT APARTMENT BUILDING WITH FUTURE RETAIL SPACES. 7 STORY  LOW RISE BUILDING. VARIANCE TO SEPERATE FIRE ALARM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28438	13041-10000-03500	820-836 S LA BREA AVE	90036	4	132B181   386	5084003047	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM			PC Info Complete	06/05/2013 12:00:00 AM	ADDRESS	34.06001	-118.34466	PLAN CHECK FOR METHANE MITIGATION SYSTEM FOR LEVEL V.  ADDITION TO A COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28439	14041-10000-23701	13456 W VENTURA BLVD	91423	4	165B157  1187	2373007007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.14693	-118.42684	TI to existing restaurant.  Total area = 1,180 sq. ft.  Installation of new lighting fixtures.Building permit submitted before title 24 part 6 effective date.Building permit #: 14016-10000-12074	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28440	16041-10006-39304	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS.SCOPE INCLUDES CHANGES OF AIC RATING FOR SWITCH BOARDS AND PANELS  BASED ON DWP FAULT REOPORT. CHANGES TO SINGLE LINE AND PANELS PER INSPECTION TO REFLECT CHANGES ON THE FIELD.THIS IS PLAN CHECK ONLY!	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28441	18041-10000-39398	1031 S BROADWAY	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	05/21/2024 12:00:00 AM	ADDRESS	34.04041	-118.2583	PLAN CHECK FOR FIRE ALARM SYSTEM FOR HIGH RISE BUILDING USING 1 FIRE ALARM PANEL WITH 264 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28442	19041-10000-17378	18915 W SUPERIOR ST	91324	12	201B121   449	2762039016	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.2465	-118.54541	Permit fee is $0.00 due to AB1414.PV1. NEW SINGLEFAMILY ROOFTOP SOLAR SYSTEM WITH TESLA POWERWALL. SYSTEM CONSIST OF 3000 SQ.FT OF INTEGRATED ROOFTILE SOLAR PANELS, THREE CENTRAL INVERTERS ( DELTA SOLIVIA 5.2, 5.2, 3.8), AND TWO TESLA POWERWALL BATTERIES. SYSTEM SIZE IS 16.38KWdc AND 14.2KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28443	14041-10002-12932	189 S THE GROVE DR # Q-30	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM			PC Approved	07/22/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	CHANGES TO AN APPROVED SET, NOTE CHANGES ON DELTA 14. SCOPE INCLUDES CHANGE OF CURRENT LIMITER FOR TRACK LIGHTING REVOMING FIXTURES FOR TRACK LIGHTING. (((PLAN CHECK FOR POWER AND ENERGY FOR NIKE STORE AT THE GROVE. EXISTING SERVICE, NEW LOADS AND PANELS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28444	17041-20001-34519	3333 N ALANA DR	91403	5	159B141   364	2280025024	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.13165	-118.47767	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) for SFD.11.4kW ungrounded pv system. (47) 325W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28445	14041-20000-13960	5121 N PENFIELD AVE	91364	3	171B113   310	2166008017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.16405	-118.56871	PV1.  Install 7.65 kW roof-mounted utility-interactive PV system.  Transformerless inverter w/ power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28446	10041-10000-01771	3742 S FLOWER ST	90007	9	117A201    14	5037030023	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	04/29/2010 12:00:00 AM		Permit Finaled	06/21/2011 12:00:00 AM	ADDRESS	34.01663	-118.28178	CHANGE OF USE FROM PARKING GARAGE TO RESTAURANT.  Install general and emergency light.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28447	13041-10000-04073	5319 W SUNSET BLVD	90027	13	147A195    86	5544019008	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM			PC Info Complete	02/15/2013 12:00:00 AM	ADDRESS	34.0983	-118.30627	TI IN AN EXISTING EL POLLO LOCO RESTUARANT.  PLAN CHECK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28448	18041-10001-48331	1900 W 3RD ST	90057	1	133-5A205  78	5154027029	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			05/02/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	34.06186	-118.27049	Resubmittal due to more than 50% change in single line diagram. This is plan check only, permit will be issued under master #18041-10000-48331CHANGE OF USE TO CONVERT EXISTING 136 GUESTROOM MOTEL TO INTERIM HOUSINGSERVICE UPGRADE TO 2000 AMPS. BUILDIING PERMIT: 18016-20000-31060	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28449	16041-10000-20511	2219 N PARKSIDE AVE	90031	1	138A227   240	5211013024	R3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	Yes	1991.20	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Expired	07/16/2018 12:00:00 AM	ADDRESS	34.07097	-118.20024	PV SYSTEM WITH CENTRAL INVERTER 3.8KW AC USING 10 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28450	17041-20000-09891	12601 W PIERCE ST 41, 42, 53	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 41, 42, and 53).20kW AC/ 23.56Kw DC ungrounded system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28451	15041-20002-15771	2248 N PANORAMA TER	90039	4	148-5A205 358	5432025014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM			PC Approved	04/14/2016 12:00:00 AM	ADDRESS	34.10023	-118.2696	04-14-2016 Changes to an approved set of plans. Changes have been made to the PV module layout and the meter socket has been removed, as it is no longer required.*****Previous Work Description*****Changes to an approved set of plans. Changes are only to the PV modules layout.*****Previous Work Description*****Plan check for PV roof monted system. System size: 3.6kW with 17 modules and 17 microinverters connected to 200A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28452	17041-10000-04737	427 W 5TH ST 1-347	90013	14	130-5A211 169	5149028012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Closed	10/03/2019 12:00:00 AM	ADDRESS	34.04937	-118.25245	PC FOR POWER. TEMPORARY POWER.  NEW  24 STORY 347 UNIT HIGHRISE APARTMENT BUILDING WITH GROUND FLOOR RESTAURANT (CORE &SHELL)  AND  SUBTERRANEAN PARKING GARAGE. NEW TWO 1000 A  480/277 V SERVICE. B# 15010-10000-02769	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28453	14041-10000-27549	7435 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.20582	-118.48615	variance has been filed on 2/17/2015 for two separate services per DWP letter justification. PLANCHECK FOR POWER AND ENERGY. 2 NEW HANGARS and core and shell. 2-STORY OFFICE tenant space to be pulled under separate permit.  TOTAL AREA 88852 SQ FT(UNCONDITIONED+ CONDITIONED+ OUTDOOR)B# 14010-10000-03213.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28454	19041-10000-22798	783 W GATUN ST # 275	90731	15	021B197  1087	7445002***	[T][Q]RD1.5-1	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.75748	-118.29434	pc for pv-1, system size is 5.51KWdc  and 5KWac. 19 modules (solaredge rec290tp2) with 19 optimiziers (solaredge p320). 1 solaredge inverter (se5000h-us).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28455	15041-30000-37864	5127 S TOWNE AVE	90011	9	108B205    82	5109024034	RD1.5-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	33.99573	-118.26753	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28456	17041-10000-02751	6550 W SANTA MONICA BLVD	90038	13	144B185   750	5533012027	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.09059	-118.3322	Plan check for Title 24 only outdoor lighting in existing space, remove HID fixtures and replace with new LED fixtures. Total area: 5,350 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28457	12041-10001-16485	8121 W MULHOLLAND TER	90046	2	156B173   323	2381029004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2012 12:00:00 AM			PC Info Complete	10/18/2012 12:00:00 AM	ADDRESS	34.12381	-118.37668	SUPPL. APPLICATION FOR AN ADDITIONAL CIRCUIT FOR THE SOLARGAURD METER.Plan check for new roof mounted 5.04KW photovoltaic system (SolarEdge transformerless inverter) using solar DC-DC powerbox. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28458	12041-10000-09894	20101 S HAMILTON AVE B133	90502	15	054B197   127	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	33.84769	-118.28637	remodel conference rooms and divided a room into a storage room and an office.No changes to any other areas.Plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28459	16041-10000-08009	17383 W SUNSET BLVD FL 4-BLDG A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, INTERIOR TI IN THE ELEVATOR LOBBY AND CORRIDOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACELS. TOTAL SQ. FT. 1735.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28460	15041-10000-21911	10320 N RESEDA BLVD	91326	12	204B125   114	2731016007	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.2579	-118.53585	PC FOR ENERGY. T.I FOR NAIL SHOP. TOTAL AREA 680 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28461	19041-10000-40811	3415 S SEPULVEDA BLVD SUITE 200	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.02055	-118.42347	T-24 ENERGY PC ONLY FOR PROPOSED INTERIOR TENANT IMPROVEMENT TO CONVERT MULTI-TENANT FLOOR TO SINGLE TENANT. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 6371 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28462	17041-10001-00690	5860 W JEFFERSON BLVD	90016	10	120B173  1729	4205027022	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.02504	-118.37633	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO LIGHTING LAYOUT - UPDATED TITLE 24, UPDATED FLOOR PLANS AND PANEL SCHEDULES. UPDATED SINGLE LINE TO SHOW ALUMINUM FEEDERS AND REVISED MAIN SERVICE TO PROPERTY. ALL CHAGES CLOUDED DELTA 2 ON PLANS. CIRCUITS ADDED FOR MOTOR SHADES. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28463	16041-20000-13678	9714 N BOTHWELL ROAD	91324	12	201B117   387	2761032013	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.24677	-118.56118	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD CENTRAL INVERTER PLAN. SYSTEM SIZE: 9.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28464	15041-10000-41417	9534 W SAWYER ST	90034	5	129B165   967	4309010018	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	PIN	34.04576636	-118.39648335	PV1, INSTALL 5.83 KW DC ROOF-MOUNTED SOLAR ARAY ON A SINGLE FAMILY HOUSE.(22) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28465	16041-10000-05836	610 S BROADWAY	90014	14	129A211   192	5144002018	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.04624	-118.25211	REPLACING THE FIRE ALARM PANEL AND DEVICES TO A FIRE ALARM SYSTEM IN A COMMERCIAL BUILDING. (235) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL. CORE AND SHELL ONLY; NOT IN TENANTE SPACES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28466	19041-10001-16889	7940 N FAIR AVE	91352	6	189B173   285	2314007028	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM			PC Approved	10/15/2019 12:00:00 AM	ADDRESS	34.21509	-118.37456	Relocating Electrical equipment on the roof-layout. (((PV1. SYSTEM SIZE OF 5.49 KWDC AND 4.66KWAC WITH (18) MODULES WITH OPTIMIZERS P320, (1) INVERTER 5000H.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28467	16041-20000-24387	15225 W STAGG ST UNIT #5-#6	91405	6	189B145   509	2209032031	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.21218	-118.46485	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EXISTING PREP KITCHEN. "" MASALA INC"" 449 SQFT. UNIT #5-#6"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28468	14041-10000-20765	1800 CENTURY PARK EAST 5th floor	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	PIN	34.06270629	-118.4150769	PLAN CHECK FOR ENERGY ONLY FOR RESTROOM AREA ON THE 5TH FLOOR. PART OF A HIGHRISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28469	17041-10000-45636	6925 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			Reviewed by Supervisor	12/26/2017 12:00:00 AM	ADDRESS	34.19646	-118.49256	FULL PLAN CHECK FOR CHANGE OF USE FROM WAREHOUSE TO AUTOMOBILE SALES/SHOWROOM. SCOPE INCLUDES NEW EQUIPMENT AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28470	13041-10000-33857	8018 W BEVERLY BLVD 1st Fl	90048	5	138B177   470	5511003023	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.07593	-118.3645	on the first floor of a 3-stories motel, remodeling the lobby and office areas Also, there are outside luminaires installed..plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28471	18041-20002-44520	741 S BOYLE AVE	90023	14	124-5A221  58	5183021018	R3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Apartment			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.03684	-118.21912	6/6/2019changes to an approved set of plans.  changes to reflect field conditions.  changes to the subpanel.this is plan check only.  ((((Work description correction: PV2.  Install 8.58 kW roof mounted grid tied PV system.  (26) modules with 7.6 kW rated string inverter.Plan review for apartment PV plans.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28472	14041-20000-20278	8751 N WHITE OAK AVE	91325	12	195B129   338	2768012037	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Expired	09/08/2016 12:00:00 AM	ADDRESS	34.23016	-118.52026	System redesign.  Downsized to 40 Originally plan checked under 14041-20000-19233 (zoning clearance obtained).  Decrease in number of modules and in AC power rating of (2) inverters.  Original work description: PV1.  Install roof-mounted solar array on SFD. System size: 12kW(2) SolarEdge #SE6000A-US-ZB-U transformerless inverters(66) SolarEdge P300 power optimizers(66) Trina Solar #TSM-255PA05.18 pv modules)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28473	15041-20000-33301	11917 N RICASOLI WAY LOT 9	91326	12	216B109   121	2701078***	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.28909	-118.58488	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. USING TOTAL OF 24 MODULES. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28474	10041-10000-10474	1075 N WESTERN AVE 101-109	90038	13	144B193   779	5536019024	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	PIN	34.09038224	-118.30940652	Replace 600 Amp meter with three 200 amp. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28475	14041-10000-17464	350 S GRAND AVE	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Expired	08/05/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	NEW LIGHTING FOR HIGH RISE OFFICE BUILDING. TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28476	14041-20000-16271	5161 N LANKERSHIM BLVD 1st  &-2nd Floor	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.16452	-118.37469	"T.I. to existing building on 1st and 2nd floors.  Install general/emergency lighting in corridor and elevator lobby areas.  Plan check for energy only. ""COMPLY WITH DEPARTMENT ORDER effective date10/28/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28477	10041-10000-03204	5757 W CENTURY BLVD #685	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM			PC Approved	02/23/2010 12:00:00 AM	ADDRESS	33.9457	-118.38274	TI in an existing office area in suite # 685. Plan Check is for Title 24- emergy calcs & emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28478	19041-10000-50279	8040 W MANCHESTER AVE	90293	11	096B153   618	4118002101	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	03/04/2020 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	33.95901	-118.43632	$0 FEE PER AB1414. PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 143 MODULES (SPR-E20-435), WITH 143 OPTIMIZERS (SE P730) AND 2 INVERTERS (SE 43.2K AND SE14.4K). SYSTEM SIZE IS 57.6KW AC AND 62.2KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28479	15041-10000-40351	1363 W 37TH PL	90007	8	117B197    71	5040010025	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.02008	-118.29929	PV1 SFD TOTAL SYSTEM SIZE 3.6KW AC USING TOTAL OF 16 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28480	14041-20001-31853	4926 N ENCINO AVE	91316	5	168B129   105	2290004026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.16013	-118.51402	Fee for expedite only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28481	14041-20002-11075	7900 N BALBOA BLVD BLDG M	91406	6	189B133   403	2205006902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM			PC Approved	06/15/2015 12:00:00 AM	ADDRESS	34.21347	-118.50092	06-15-15 Change to approved set of plans. Changes include replace 20A circuit breakers with 30A circuit breakers for PTAC{{{{{{Change to approved set of plan. Changes include remove EXO T, S,R, Q  for MSB-M and replace with Future panels. Remove EXO P,K,O for MSB-N and replace with Future panels. Add 13 panels on Panel M. Add 12 panels to Panel N.  [[[[[PC FOR NEW SERVICE. BUILDING N. NEW 800A. ALL LOADS FUTURE. THIS IS PLAN CHECK FOR SERVICE ONLY.]]]]]}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28482	12041-10000-28125	15231 1/2 W LA CRUZ DR	90272	11	129B125   771	4412002018	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.02	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	PIN	34.04579269	-118.5252026	T.I.  Existing restaurant in a one story building.  Modification to the interior lighting. Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28483	18041-20000-39767	13570 W FOOTHILL BLVD bldg-1	91342	7	222B157   200	2513006900	RD1.5-1XL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			10/29/2018 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	01/29/2021 12:00:00 AM	ADDRESS	34.30638	-118.42945	New 3-story 21-affordable units apartment.  Scope of this permit is building 1 out of 2 apartment buildings on site.  1600A, 208Y/120V 3ph-4w service (located on Building 1) supplying both buildings 1 and 2 (single feeder).Building permit under 18010-10000-03808.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28484	04041-10004-31759	1925 W WILSHIRE BLVD	90057	1	132A203    23	5142001022	C4-2	Central	Westlake		YES	2089.02	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM			PC Approved	10/08/2010 12:00:00 AM	ADDRESS	34.0574	-118.27431	RENOVATION FOR THE LA OPEN DOOR PRESBYTERIAN  CHURCHREVISIONS TO APPROVED SET OF PLANS-CHANGING THE MANUFACTURER OF THE CIRCUIT BREAKERS IN PANELS HA, HB, AND HP FROM SQUARE D TO CUTLER HAMMER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28485	09041-10009-24366	3327 E SABINA ST Bldg A	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			01/19/2012 12:00:00 AM			PC Approved	01/19/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 7 Revision to approved plans for New Apartment Complex w/ multiple buildings (Bldg A) 1of 2 Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28486	15041-20000-03040	14540 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.23519	-118.44926	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO DOLLAR KING. 8700 SQFT, EMERGENCY LIGTHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28487	16041-20000-45427	21200 W TULSA ST	91311	12	207B105    81	2706031022	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Issued	01/31/2017 12:00:00 AM	ADDRESS	34.2674	-118.59483	PV1.  Addition to an existing system. Install roof mounted PV system sized 7.6kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28488	19041-10000-34120	3434 W 1ST ST	90004	13	138B197   812	5501015011	C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	34.07334	-118.28811	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28489	13041-10000-08111	1973 S STEARNS DR	90034	10	126B173   798	5066010030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.04015	-118.37484	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.92 KW. USING TOTAL OF 16 MODULES. TRANSFORMERLESS SYSTEM, NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28490	12041-20000-05325	10332 N TOPANGA CANYON BLVD	91311	12	204B101   114	2722018042	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.25829	-118.60584	New places of assembly building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28491	10041-10000-18207	2070 S CENTRAL AVE	90011	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.02263	-118.25198	DEVELOPEMENT OF FIRST TENANT SPACE; SHELL PERMIT INCLUDE TENANT PANELBOARD AND SOME CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28492	11041-20000-09529	8133-8135 N CLYBOURN AVE	91352	6	189B177   955	2407025008	[Q]MR1-1-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.21828	-118.36495	INTERIOR T.I.  (FIRE REPAIR) Installing 2 New panels & adding new circuits. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28493	15041-20000-10259	3900 N STANSBURY AVE	91423	4	162B153  1094	2274027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.14084	-118.44264	Title 24 plan check only.  Total area = 10,860 sq. ft. (indoor) + 820 sq. ft. (outdoor)T.I. to existing school administration building.  400 A new connected load.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28494	17041-20000-18419	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28495	17041-10000-28445	1301 S FIGUEROA ST	90015	9	126A205     9	5134007933	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.04058	-118.26853	Permit fee is $0.00 due to Senate Bill 1222.Installing 1.68MW solar system on top of the roof of LA convention center. Installing 28 60kW inverters with 6228 modules. Note that this installation is divided into two parts each supplying 840kW (14 Inverters) and connected to its own meter. BLD plan check number 17016-10000-22889.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28496	14041-10000-14885	12671 W SANDHILL LANE # 1 - 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	33.97727	-118.41516	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28497	11041-10000-05086	729 S FLOWER ST	90017	14	129A209    93	5144010025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM			PC Approved	03/15/2011 12:00:00 AM	ADDRESS	34.0481	-118.25957	Instalation of parking lights. EPC is for T24 and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28498	14041-20000-32602	10450 W ILONA AVE	90064	5	129B157  1119	4315006040	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.04702	-118.41941	PV1Using Standard Plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.6kW. Ungrounded system.18 255W pv modules across 3 strings (6+6+6).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28499	15041-20001-32156	6630 W SUNSET BLVD	90028	13	147A185    75	5547024006	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Apartment			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.09782	-118.33424	plan check only, supplemental for changes to approved set, reduction of service size down to 2500A, change of series rated breakers on single line diagram, minor changes to floor plan, change to fault current calcs, and updated LADWP available fault current letter. clouded changes only.*original*Plan check for power and energy. Project site is a new 6-story, mixed-used apartment building. Building is 5 levels of residential (40 units) over 1 level of retail, with 2 levels of underground parking. Underground service size is 3000 Amps. Total indoor lighting area = 38,810 sq. ft. and total outdoor lighting area = 1,542 sq. ft.Note: Building application has been filed under 13010-10000-01079	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28500	16041-10000-37626	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM			PC Approved	11/07/2016 12:00:00 AM	ADDRESS	34.03365	-118.24048	T-24, NEW LIGHTING IN A PARKING STRUCTURE TOTAL SQ. FT. 1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28501	19041-10000-17260	12207 W HESBY ST	91607	2	171B165   916	2356014019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.16227	-118.39893	0$ FEES PER AB 1444 AND SB 1222Plan check for a 9.6kw AC roofmounted system with (30) AC modules, (2) battery power supplies, and (3) subpanels interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28502	13041-20000-23320	11456 N CABRIOLE AVE PV-1	91326	12	213B121   521	2871014017	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.27906	-118.5432	PV-1. Plan check for sfd. One 3.6kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28503	13041-20000-12767	414 S HIGHLAND AVE	90020	4	135B185   278	5507014003	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	PIN	34.06640911	-118.33811746	PV1 SINGLE FAMILY DWELING. USING ENPHASE MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 5.18KW. USING 24 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28504	18041-10000-42166	2643 E 25TH ST	90058	14	117A219   115	5168022006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.01546	-118.22426	PC FOR REPLACMENT OF INDUSTRIAL EQUIPMENT. TOTAL CONNECTED LOAD > 400ASCOPE INCLUDES NEW SECTIONS IN ALL MCCS WITH NEW EQUIPMENT. 3 BLDG PERMITS, 1 FOR EACH PHASEB#18016-10000-26599B#18016-10000-35703B#18020-10000-02766	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28505	17041-20000-20172	1328 S SANTA FE AVE	90021	14	121-5A217 172	5168031005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.02781	-118.22976	Plan check for power and energy. Change of use from warehouse/office to office/retail. TI to power distribution system. Existing service and main service panelboard (MSA) - all other work is new. T24 area - 18,099sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28506	11041-20000-11356	9189 N DE GARMO AVE	91352	6	198B173   125	2408034042	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.23604	-118.37603	Plan check power for new equipment building at an existing recycling facilty.  3 underground feeders supplying building and equipment. Site in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28507	13041-20000-16454	523 W 6TH ST SUITE 1003	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	RENOVATION OF EXISTING OFFICE SPACES. PC FOR T24 ENERGY ONLY. NEW LIGHTING FIXTURES. TOTAL AREA 8266 SQ FT. PERMIT WILL BE ISSUED FROM THIS APPLICATION. WORK DONE IN SUITE 1003	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28508	18041-10002-22778	3717 W 64TH ST	90043	8	105B185   986	4004034037	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	33.98188	-118.3383	Change to approved set by updating the scope description. NEW ROOF TOP SOLAR SYSTEM TO A  RESIDENTIAL BLDG, PER APPLICANT. (18) MODULES AND  (1) 5.2KW INVERTER. TOTAL SYSTEM SIZE IS 5.2KWAC/5.49KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28509	10041-20000-19254	5301 N MANTON AVE	91367	3	171B093    80	2044011007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2010 12:00:00 AM	12/02/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	34.16819	-118.64193	Plan check new roof mounted 20.16KW P.V. system for single family dwelling.  EPC for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28510	18041-10001-18152	2308 S CASTLE HEIGHTS AVE	90034	5	126B165   279	4309008003	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM			PC Approved	05/21/2018 12:00:00 AM	ADDRESS	34.04345	-118.39761	**expedited per applicant**New rooftop solar system and storage battery on SFD, (11) modules with (11) power optimizers, (1) 5.2 kW inverter, (1) 13.5 kWh ESS, (1) 125A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28511	12041-10000-05675	926 S CROCKER ST #1;2;3-SPACES	90021	9	124-5A211 165	5132002019	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.0355	-118.24971	FIRST TENANT- TENANT OCCUPYING SPACES  1;2;3 ;SHELL AND CORE ON #11041-10000-07465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28512	13041-10000-32414	1822 W 50TH ST	90062	8	111B193  1146	5015007005	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	33.99788	-118.3121	PV1, Install 1.5 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter.  Power-One Aurora PVI-3.0-0utd-s-us. 6 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28513	12041-10000-29808	17401 W VENTURA BLVD A-39	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	ADDRESS	34.16136	-118.51189	TI FROM RETAIL TO CHIROPRACTOR. STE A-39. 1ST FLOOR OF MALL. MALL DOES NOT HAVE GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28514	14041-20000-26210	16110 W LOS ALIMOS ST	91344	12	207B141   295	2667026002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Expired	10/31/2016 12:00:00 AM	ADDRESS	34.26541	-118.48303	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.  PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.(40) KYOCERA KD255GX MODULES(40) POWER OPTIMERS(2) SOLAR EDGE SE 5000 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28515	16041-10000-20108	363 S MISSION ROAD	90033	14	127-5A219 302	5172014017	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.04231	-118.22736	PC for T-24 only, remove HID fixtures and replace with LED fixtures. Total area: 14,436 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28516	16041-20000-17851	12103 N VISTA RANCH AVE	91342	7	216B145   303	2611038029	A2-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.28971	-118.46093	Plan check for PV roof mounted system. System size: 4.5kW with 14 AC modules. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28517	15041-20000-03074	12491 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	33.97895	-118.41081	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28518	10041-10000-22686	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	T.I. at LMU, removing parking lighting to 277 circuiyts and installing 10 circuits to charge electric vehical.  Circuits are single pahse 120 volt, Title 24 is submitted for outside area.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28519	17041-10000-32859	14843 W VENTURA BLVD	91403	4	168A149   189	2264017026	(T)(Q)C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	10/26/2020 12:00:00 AM	PIN	34.1530148	-118.45680392	PC for power and energy for new retail building. Installing new 200A panels (HS and LS), 45kVA transformer, new lights and circuits. Building# 17010-30000-03544.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28520	17041-10000-24842	835 W JEFFERSON BLVD 7A & 7B	90007	9	121-5A201 201	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM			PC Info Complete	08/16/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	TI TO (E) CORE SHELL RESTAURANT SPACE. PC FOR POWER AND ENERGY. 3 NEW PANELS AND CIRCUITS FOR KITCHEN EQUIPEMENT, LIGHTING AND PLUGS. TOTAL AFFECTED AREA OF 2453 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28521	15041-10001-37487	1674 W HILL DR	90041	14	163-5A225  72	5669018001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM			PC Approved	11/25/2015 12:00:00 AM	ADDRESS	34.14358	-118.20282	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<<<PV1, INSTALL  8.7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, WITH BATTERY CHARGE, AND  ONE 100A  SUB PANEL. MAIN PANEL 400A. (1) INVERTER : CONEXT XW+ SERIES XW+6848NA(24) MODULES: SUNBODULES PRO-SERIES SW 315-320 MONO>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28522	14041-10000-17121	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	01/24/2024 12:00:00 AM	ADDRESS	34.03941	-118.25893	Renovation of an existing 13 story Club building. Change of Use to Hotel with restaurant on 1st floor,  New Restaurant on Roof with spa/pool.  New bar in Basement (core and shell only).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28523	13041-10000-23158	431 S COLYTON ST	90013	14	127-5A215 327	5163025008	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.04251	-118.23648	second commercial building supplied from new 5000A  service section located at 440 S Seaton St Switchboard (MSB)  is 800A that supplies loads for the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28524	16041-10000-34760	690 S ALAMEDA ST	90021	14	124-5A215  52	5164023025	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.03528	-118.2384	Plan check for Title 24 only in existing space T.I. dining area. Total area: 1,366 sq ftchange Existing lighting interior dining/restroom lighting to LED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28525	14041-20000-29029	17830 W MERRIDY ST	91325	12	204B129   522	2734007003	(Q)R3-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.25201	-118.52273	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 26KW(84) CANADIAN SOLAR CSX(1) FRONIUS 11.4-3(1) FRONIUS 10.0.3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28526	16041-10000-34346	11550 N INDIAN HILLS ROAD	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	04/25/2017 12:00:00 AM		Issued	04/25/2017 12:00:00 AM	ADDRESS	34.27998	-118.45874	PC FOR T24 ENERGY ONLY FOR LIGHTING IN PARKING GARAGE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28527	13041-20001-22250	13501 W CHASE ST	91331	6	195B157   264	2625034029	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.2334	-118.4266	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW USING 18 MODULES. TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28528	10041-20000-07768	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			PC Approved	04/27/2010 12:00:00 AM	ADDRESS	34.17126	-118.58861	Installing 3 circuit in medical office in NORTHSIDE MOB of the building on 1st, 2nd and 3rd floor.  plan check is for the three circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28529	17041-10000-29529	5019 W MAPLEWOOD AVE 1-5	90004	4	141B193  1079	5522013011	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			08/18/2017 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.08043	-118.31178	NEW 5 UNIT APARTMENT. NEW 600A SERVICE AND HOUSE PANEL. PC FOR POWER AND ENERGY. TOTAL AFFECTED AREA IS 8225 SQ. FT. B#16010-10000-00592	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28530	16041-20000-34959	3825 N MISSION ROAD	90031	1	136-5A227  10	5211011031	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.07009	-118.19958	"New 2000 amp service for a three story classroom building B occupancy.  Reconnect existing distribution ""MS"" to new board ""MSN."" Plan check for power and energy.  Total square footage - 7256 sq ft."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28531	17041-10000-43426	13407 W BRANFORD ST	91331	6	195B157   353	2625039022	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.23261	-118.42483	Plan check for PV roof mounted system. System size: 5.0kW with 24 modules and 1 inverter(5.0)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28532	16041-20002-11387	8301 N CANOGA AVE	91304	3	192B105   594	2779036013	C2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.22025	-118.59775	1.11.2018 - Plan check and permit for modifications to approved set.  Equipment AIC rating changes, (2) additional subpanels, relocation of (2) AC load connections from distribution board to subpanel AC.  =======7.12.2017 - Plan check for modifications to approved set. Indoor floor layout rearranged - update lighting plan power plan, and indoor T24 documents - changes clouded. Changing service from 400A 480/277V to 800A 208/120V - Recheck entire SLD. =======Plan check for power and energy. Project site is a new gas retail/market building and gas station. DWP service is existing (gas station is replacing car wash). Total lighting area = 24,086 sq. ft.Note: Building permit has been created under 16010-20000-00069	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28533	11041-10000-15375	1408 W WASHINGTON BLVD	90007	1	126A201   178	5056026040	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2217.10	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.0398	-118.28697	FIRE ALARM SYSTEM FOR NEW 41-UNIT CONDOMINIUM BUILDING.  PLAN CHECK IS FOR FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28534	11041-20000-27560	3819 N SHERVIEW DR	91403	5	162A147   113	2278026033	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.1387	-118.46354	New pv system roof mounted.  Inspector to verify that each page of the plan shall the printed and  signed name of  Mr. Peter Smith, the electrical contractor license holder for Verengo solar.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28535	19041-20000-46051	334 E SUNSET AVE	90291	11	109-5A143  67	4286007021	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	33.99545	-118.47421	T24 PLAN CHECK, LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 6540 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28536	15041-10000-31539	19191 S VERMONT AVE 1st floor	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	33.85656	-118.29099	T-24 for interior lobby and exterior walkway plaza. Total area: 8952 q.ft Scope of work on 1st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28537	19041-10000-07450	12309 W MILBANK ST	91604	2	168B165   986	2364014031	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	06/29/2019 12:00:00 AM	ADDRESS	34.15326	-118.40116	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(DELTA SILIVIA 5.2TL) WITH 2 ENERGY STORAGE SYSTEM(POWER WALL) USING SOLAR TILES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28538	13041-10000-26186	10948 N OSO AVE	91311	12	210B113   138	2707031008	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.26913	-118.57623	""" $0 permit fee is due to the 2012 Senate Bill No. 1222""PV1. ROOF MOUNTED 14.5kW PHOTOVOLTAIC SYSTEM WITH TWO TRANSFORMERLESS INVERTER AURORA PVI-6000"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28539	19041-20000-16940	5121 N BAKMAN AVE	91601	2	171B173   806	2353002020	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.16358	-118.37751	Plan check for replacing 600A  meter equipment for apartmet building; 600A service pull section existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28540	12041-20000-20475	17461 W VENTURA BLVD	91316	5	171B129   410	2257016054	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			PC Approved	08/29/2012 12:00:00 AM	ADDRESS	34.16157	-118.51326	energy plan check market revision to approved plans	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28541	19041-10000-37740	9946 N SHOSHONE AVE	91325	12	204B129   546	2734019002	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.25188	-118.51701	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 12.3 KVA PV1 SYSTEM CONSISTING OF 39 MODULES(SUNPOWER 320- #SPR-320E-WHT-D) WITH MICRO INVERTERS(ENPHASE IQ7X-96-2-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28542	16041-20000-25397	8807 N BALBOA BLVD	91325	12	195B133   315	2690009006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM			Reviewed by Supervisor	08/05/2016 12:00:00 AM	ADDRESS	34.23051	-118.50278	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 14.2KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28543	12041-10000-01223	203 N HOBART BLVD	90004	4	138B193   633	5517011008	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10, 2114.20	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2012 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Expired	03/12/2014 12:00:00 AM	ADDRESS	34.07542	-118.30564	New 2.4kw photovoltaic, rooftop, system for an existing single family dwelling usinf Enphase M215 microinverters.  Solar clearance and Permit are on previously pulled application# 12041-10000-00487. All conduits to remain outside of building. Additional permit for microinveters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28544	18041-10000-36999	5609 S BROADWAY	90037	9	108B201  1007	5101038012	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2328.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	33.99114	-118.27849	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28545	13041-20000-33098	2232 N VISTA DEL MAR PL	90068	4	151-5A189  37	5585028006	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.11119	-118.32399	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 2.8KW. 13 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28546	15041-10000-04902	21200 W LASSEN ST	91311	12	201B105    86	2746004046	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.24983	-118.59403	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL  AREA 39710 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28547	12041-10000-19604	12804 W RAYMER ST	91605	2	186B161   548	2324005032	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.20407	-118.41179	Plan check roof mounted 69.62KW photovoltaic system for existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28548	14041-10000-01585	3941 S MARCASEL AVE	90066	11	111B157    77	4214021014	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.00415	-118.42563	PV1, Install 6 kW DC roof-mounted solar array for a one story house, interconnect with exsisting service panel. (1) Inverter(s): POWER-ONE AURORA PVI-6000-OUTD-US.(24) Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28549	15041-10001-23436	1068 S POINT VIEW ST	90035	5	132B173   772	5087024023	R1-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2015 12:00:00 AM			PC Approved	09/10/2015 12:00:00 AM	ADDRESS	34.05667	-118.36777	((EXPEDITE FEES))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. 28 MODULES AND MICROINVERTERS. TOTAL SYSTEM SIZE 8.4KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28550	16041-20001-37739	5207 N ZELZAH AVE	91316	5	171B129   174	2162007069	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.16559	-118.52221	expedite per applicant.pv2install roof mounted pv system sized 9.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28551	17041-20000-36809	7347 N ATOLL AVE	91605	2	186B157   409	2327001057	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	34.20424	-118.42119	TI to (E) commercial storage areas.  Plan check for energy - 900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28552	12041-10000-03604	21550 W OXNARD ST #125	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM			PC Approved	02/16/2012 12:00:00 AM	ADDRESS	34.179	-118.60001	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT OF EXISTING RESTAURANT SUITE #125 IN HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28553	16041-10000-21851	11634 W MORRISON ST	91601	2	168B169   100	2354009005	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.16027	-118.38667	NEW PV SYSTEM 10KW AC ROOF MOUNTED. INCLUDES (36) MODULES: CANADIAN SOLAR:CS6P-265P  AND ONE INVERTER: SOLAREDGE SE 10000A-US(240V).	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28554	17041-10000-30205	1401 E ANAHEIM ST	90744	15	030B213    25	7425039005	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	33.78104	-118.24583	PC FOR TITLE 24 ENERGY ONLY FOR PARKING LOT WITH A GUARD BOOTH. SCOPE INCLUDES NEW CIRCUITS, LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA  62,680 SQ.FT. Guard booth app# 17010-10000-01346Yard app# 16026-10000-00105	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28555	12041-20000-30756	12001 W VICTORY BLVD	91606	2	180B165   700	2322007056	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.18684	-118.39464	Plan check for power and energy.  Bakery and kitchen. Less than 100 occupants. Electrical work was within the scope of work for the Civil Engineer. 8419sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28556	16041-20000-05012	6918 N CEDROS AVE	91405	6	183B149   518	2219013019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.19633	-118.45296	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28557	16041-10000-34737	434 N POINSETTIA PL	90036	5	141B181  1363	5525025029	R2-1	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.0792	-118.34852	PV NEW 3.465 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.(11) MODULES: LG LG315NIC(1)INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28558	17041-20000-18330	9238 N KENNY CT	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.23864	-118.45912	Plan check for solar pv system, roof-mounted on SFD.3.84kW ungrounded sysetm. (12) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28559	13041-10000-27134	11613 W HAYNES ST	91606	2	180B169   686	2335005021	RD3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.18952	-118.38496	PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 2.5 kW. TRANSFORMERLESS INVERTER. SOLAR EDGE POWER OPTOMIZERS.SOLAREDGE POWER OPTOMIZERS(10) TRINA SOLAR # TSM-250PA05.18(1) SOLAREDGE # SE3000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28560	19041-10000-38018	9035 N WOODMAN AVE	91331	6	195B153   194	2639033004	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	11/09/2019 12:00:00 AM	ADDRESS	34.23371	-118.43952	Energy plan check for a retail T.I. Scope includes new lighting and equipment with a total lighting area of 10,930-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28561	15041-10001-12406	16304 S VERMONT AVE	90247	15	069B197   333	6120018084	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	33.88328	-118.29117	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 36KW INTERCONNECTED WITH MSP.  (6) SMA 6000 WATTS INVERTERS(156) CANADIAN SOLAR MODULES CS6P-255P MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28562	14041-20000-14722	7100 N FAIR AVE	91605	2	183B173   136	2319022010	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.19988	-118.37482	NEW 800A SERVICE UPGRADE. RELOCATED AC UNIT. NEW SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28563	17041-20001-45330	10412 N FULLBRIGHT AVE	91311	12	207B113   288	2707017025	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.25985	-118.57695	expeditepv1install roof mounted pv system sized 11.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28564	10041-20000-00872	15301 W VENTURA BLVD Suite 450	91403	5	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	01/19/2010 12:00:00 AM		Permit Finaled	02/25/2010 12:00:00 AM	ADDRESS	34.15411	-118.46654	Tenant improvement - relocating lights in office areas. Title 24 Mandatory Measures only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28565	19041-20002-51175	4312 N HAYVENHURST AVE	91436	5	165B137   217	2291005020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	01/13/2020 12:00:00 AM	ADDRESS	34.14943	-118.49465	EXPEDITED PV1. INSTALL 20.13 KWDC PV SYSTEM WITH (61) MODULES/OPTIMIZERS AND (2) INVERTER(SE7600).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28566	14041-20000-24768	5650 W MANCHESTER AVE	90045	11	096B169   549	4125018014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	33.95972	-118.37999	NEW PIZZA RESTAURANT. EXISTING SERVICE & PANELS. PLAN CHECK FOR NEW CIRCUITS & T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28567	18041-10000-41202	4700 S INGLEWOOD BLVD	90230	11	108B161   213	4218008012	(Q)C2-1, C2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.99346	-118.41537	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28568	16041-10000-18424	1351 S ELWOOD ST	90021	14	121-5A215 274	5167004041	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.02533	-118.23607	PC for T-24 only.  Remove HID fixtures and replace with new LED fixtures. Total atea: 2190 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28569	19041-10000-43648	6010-6020 W AVION DR UA-Hangar	90045	11	090B169    31	4129028900		West Los Angeles				2780.00	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	12/01/2021 12:00:00 AM	ADDRESS	33.94244	-118.38762	(2) Medium Voltage Step Down Transformers 4160volt to 480Y277volt, UA Hanger and GSE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28570	10041-10000-22340	11827 W VENICE BLVD	90066	11	114B157   942	4234016001	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.00775	-118.42664	New servcie of 600 amp, church building two new sub panels are added, title 24 was approved before but now modififed.  New approval for title 24 is requested.  Fault current from DWP submitted with 22000 Amp	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28571	16041-10001-00299	1608 S SAWTELLE BLVD	90025	11	129B149   347	4261007022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			Ready to Issue	01/22/2016 12:00:00 AM	ADDRESS	34.04692	-118.44861	PC for Energy only, install new lights, total area: 2,130 sq.ft.  Permit issued under 16041-10000-00299 (express) ***NEW FIXTURES OFF EXISTING CIRCUITS - (24) PENDANT LIGHTS, (10) RECESS LIGHTS, (5) SURFACE MOUNT LIGHTS, (11) LIGHT SWITCHES, (11) OUTLETS. (TRADE  OF 3, REFER TO #16044-10000-00097).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28572	14041-10000-16757	9000 W 3RD ST	90048	5	138B169   551	4335014001	(T)(Q)R4-2-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	02/14/2022 12:00:00 AM	ADDRESS	34.07338	-118.38815	New High-Rise Residential Building : Type 1-A , 13 story 58 apartments + 1 core & shell apartment on 12th &13th floor ( penthouse)  over three level of subterranean parking. Ground floor Core and shell for 1) Gymnasium 2) Private Threatre 3) Lounge-Kitchen. And Basement level 1 Kitchen Core and shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28573	16041-10000-24380	9601 N MASON AVE STE B	91311	12	201B109   284	2748003080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.24457	-118.57997	PC FOR ENERGY ONLY. REPLAEMENT OF HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 9432 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28574	18041-20000-16203	3620 S VERMONT AVE 120 & 317	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.02213	-118.29133	Plan check for Title 24 only in existing space USC Kaprielian Hall T.I. replace light fixture adding sensors, dimmers, some outlet in 1st and 3rd Floor. Total area: 1,831 sq ft.B#18016-10000-12072	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28575	19041-10001-10280	2267 W 31ST ST	90018	10	120B189   490	5052022015	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM			PC Approved	08/16/2019 12:00:00 AM	ADDRESS	34.02658	-118.31713	Plan check for a lost set of plan. (((Plan check for a 3.8KW AC / 4.13KW DC roof mounted system adding on to an existing PV system. Scope includes (1) inverter, (1) subpanel, and (14) modules and optimizer interconnecting to the main service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28576	15041-10001-01050	12550 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.97815	-118.41197	(3/3/2015) CHANGES TO AN APPROVED SET OF PLANS.  CHANGE FROM UNDERGROUND SERVICE TO OVERHEAD SERVICE.  DELTA ONE REFLECT THE CHANGES DONE ON THE PLANS. Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28577	19041-10000-49983	11111 W SANTA MONICA BLVD STE 1150	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.04771	-118.44481	TENANT IMPROVEMENT IN AN EXISTING OFFICE IN SUITE #1150. INSTALLING NEW LIGHTS. TITLE-24 ENERGY ONLY. AFFECTED AREA 2,490 SFT. BULDING PERMIT: 19016-40000-38062	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28578	19041-10000-15871	1500 S WESTWOOD BLVD	90024	5	132B153   972	4325020001	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.05401	-118.4404	Full PC for Tenant Improvement to existing Restaurant. existing service. scope of work area 1015SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28579	10041-20000-17293	8229 W FOOTHILL BLVD	91040	2	204B193   135	2555022004	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.25984	-118.31235	Firt time tenant for a new bookstore.  Install new branch circuits in an existing panel.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28580	17041-10001-32803	6363 W SANTA MONICA BLVD	90038	13	144B185   688	5533008011	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Issued	12/13/2017 12:00:00 AM	ADDRESS	34.09087	-118.32823	12-13-2017 Changes to an approved set of plan. Changes include add 13 Fire alarm devices and 1 communicaiton panel. Changes has been clouded as delta 2 ******************************Previous Wrok Description*****************************Plan check for new Fire Alarm System for new building - System consist of new fire alarm panel and 200 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28581	19041-20000-24816	435 S OCCIDENTAL BLVD	90057	1	135A201    48	5155010007	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Issued	09/03/2019 12:00:00 AM	ADDRESS	34.06531	-118.28392	RENOVATION OF CHURCH. PLACE OF ASSEMBLY. SCOPE OF WORK INCLUDES CHANGE IN LIGHTING, EXTERIOR AND INTERIOR, AND CHANGE IN DISTRIBUTION PANEL AND CIRCUITS. PLAN CHECK FOR POWER AND ENERGY. 800A SERVICE TOTAL AREA 22022 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28582	14041-10000-05805	1302 W 177TH ST BLDG C	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	INSTALLATION OF A FIREALARM FOR A  NEW 14-UNIT APARTMENT BUILDING (BUILDING C). 1 PANEL AND 66 DEVICES.3 OF 6ELECTRICAL P# 13041-10000-06847.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28583	19041-30000-08295	2049 S CENTURY PARK EAST 40th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM			PC Info Complete	03/07/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is the 40th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,216 sq. ft.Note: Building application has been generated under 19016-10000-04331	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28584	13041-10000-12292	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI OFFICE TO OFFICE. HIRISE. 3RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28585	13041-10000-17581	735 S FIGUEROA ST SPACES 111-& 112	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	permit to be pulled at EPC counter only. PC for energy only. generator supplying emergency lighting.TENANT IMPROVEMENT ON EXISTING RESTAURANT SPACE 112 (AREA 914 SQ FT) INSIDE THE FOOD COURT OF EXISTNG RETAIL BUILDING. NO ALCOHOLIC SALE OR CONSUMPTION ON SITE. MAXIMUM IF4 EMPLOYEE ON SITE.***RESTAURANT PROGRAM***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28586	11041-10000-17306	19660 W VANOWEN ST	91335	3	180B117    63	2132002007	C1-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.19364	-118.56187	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28587	14041-20000-09846	17928 W TIARA ST	91316	5	177B129   621	2159012006	R1-1	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.1789	-118.524	PV1. ROOF MOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. NON STANDARD PLAN. SYSTEM SIZE: 7.5KW.(30) CANADIAN SOLAR CS6P 250(1) SOLAR EDGE SE6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28588	19041-10000-50134	3682 N HARRIMAN AVE	90032	14	144A231   197	5213006005	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	01/02/2020 12:00:00 AM		Issued	01/02/2020 12:00:00 AM	ADDRESS	34.08845	-118.18211	EXTERIOR  LIGHTING FOR NEW 4 UNITS APARTMENT BUILDINGPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28589	10041-10000-00533	1037 S BROXTON AVE	90024	5	132B149    45	4363024008	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	01/13/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.06174	-118.44667	PLANS THAT WERE APPROVED ON 09041-10000-20931 WERE PUT ASIDE BY THE OWNERS AND RE SUBMITTED UNDER A NEW ELECTRICAL ENGINEER. ADDING NEW PANELBOARDS AND CKTS AND TITLE 24 REVIEW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28590	12041-10001-27463	500 W WORLD WAY T5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	New fire alarm system for terminal 5 of LAX.( landside redevelopment)((((((((((((((((((((((((((((  mz   7-5-13   Adding 47 additional devices to previously approved set of fire alarm system. ))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28591	10041-10000-01722	2101 E PACIFIC COAST HWY HPD	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALLATION OF A STATE OF CALIFORNIA PERMITTED PRE-MANUFACTURED BUILDING TO FUNCTION AS AN EMPLOYEE OFFICE FOR THE TESORO REFINERY, AND NEW CANOPY AND A STORAGE SHED.   <<<<>>>>  HPD AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28592	18041-20000-09133	6000 S CRENSHAW BLVD	90043	8	105B185   413	4006003001	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	33.98518	-118.33056	T-24, PC FOR ENERGY ONLY. INTERIOR ALTERATIONS INSIDE A RESTAURANT-TACO BELLIN THE KITCHEN AND DINING AREAS LUMINAIRES ARE CHANGED TO LED TYPES AND USING EXISTING BRANCH CIRCUIT TOTAL AFFECTED AREA IS 1560 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28593	16041-20001-42778	7412 N BALBOA BLVD	91406	6	186B133   704	2226029004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.20514	-118.50093	expedite per applicantpv1install roof mounted pv system sized 11kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28594	19041-10000-02527	19441 W BUSINESS CENTER DR 141	91324	12	195B117    39	2783025099	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.23152	-118.5573	T24 ONLY FOR EXISTING COMMERCIAL KITCHEN, TOTAL SQFT = 691	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28595	16041-20001-21589	10427 W LA TUNA CANYON ROAD	91352	7	195B177    68	2544023011	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM			PC Approved	06/26/2016 12:00:00 AM	ADDRESS	34.23402	-118.35835	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. AC MODULES. SYSTEM SIZE:13.11 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28596	17041-10001-19202	801 S GRAND AVE 101, 102	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM			PC Approved	04/05/2018 12:00:00 AM	ADDRESS	34.04581	-118.25842	PC FOR CHANGES UNDER DELTA 4. SCOPE INCLUDES CHANGES IN LAYOUT TO ELECTRICAL ROOM AND ADDITIONAL NOTES REGARDING THE RATING OF ELECTRICAL ROOM. THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28597	19041-20001-34534	10006 N MELVIN AVE	91324	12	204B117   551	2726011022	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM			PC Approved	10/18/2019 12:00:00 AM	ADDRESS	34.25211	-118.56081	10-18-2019 Changes to an approved set of plan, Changes include addition of PV meter. Plan check only. Fees $0.00 due to california Senat Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28598	16041-20001-23924	1441 S VETERAN AVE 1-111	90024	5	129B153   139	4324013032	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM			PC Approved	08/10/2016 12:00:00 AM	ADDRESS	34.05268	-118.44373	RSES expedited plan check feePV2.  Install 155 kW DC roof-mounted PV system.  (456) modules with (4) 24kW and (1) 20kW transformerless central inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28599	14041-20002-31034	5048 N SHIRLEY AVE	91356	3	171B117   452	2175033007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM			PC Approved	04/16/2015 12:00:00 AM	ADDRESS	34.16233	-118.55683	Changes to approved set.  Relocation of electrical equipment on side of house.*****Previous work description*****PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 19.6 DC.(60) SUNPOWER 327W(1) SMA SB8000TL(1) SMA SB10000TL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28600	14041-10001-30151	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	11/13/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	Modifications to approved set.  Removal of time clock control from conveyor catwalk maintenance lights (area constantly in use/active).   (((New lighting for temporary airport security baggage screening area on level 3 of Tom Bradely Int'l Terminal.   Replacement of less than 10% of existing luminaires in baggage pick-up area on level 1.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28601	12041-10000-17875	4722 N FORMAN AVE	91602	4	168B181   141	2420018014	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.15645	-118.35171	New Enphase, 8.93kw, rooftop PV system for an existing SFR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28602	14041-10001-01561	2736 N ARMSTRONG AVE	90039	4	150A207   143	5439023008	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.10596	-118.2662	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with exsisting service panel. (1) Transformerless inverter(s):n Solaredge SE3800A-US-ZB-U. (18) Modules TRINA SOLAR TSM-250PA05.18.(18) Optimizer:SOLAREDGE P300-2NA4AZS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28603	10041-10000-01498	1240 N VINE ST	90038	13	144B189   181	5534001400	(Q)C2-1-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	03/01/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.09383	-118.32643	Plan check for T-24 energy (general/emergency lighting) TI Office Depot.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28604	18041-20000-11895	3500 S CHESAPEAKE AVE	90016	10	120B181  1018	5046015030	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Apartment			04/03/2018 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.02354	-118.34506	Plan check for power and energy. Project site is a 3-story, 22-unit apartment building with a basement parking garage. Work includes a 1,200-amp service and a total lighting area of 16,750 sq. ft.Note: Building application has been generated under 18010-20000-00374	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28605	17041-10001-09030	505 N SILVER LAKE BLVD	90026	13	139-5A203 706	5401013010	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	Apartment			01/29/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	07/15/2022 12:00:00 AM	ADDRESS	34.078	-118.28001	Change to approved set of plans. All changes are clouded under delta 1. Changes include adding an additonal floor on top of a 4-story apartment building with (12) additional dwelling units. Revising Service load calculations, single line diagram, emergency photometrics, and revising Title 24 calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28606	10041-20000-03255	11150 W SANTA MONICA BLVD s.1550	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM	02/24/2010 12:00:00 AM		Permit Finaled	03/25/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	s.1550 office t.i.Energyexit signs are existingFire Alarm is by others 10041-10000-03064	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28607	15041-10000-28325	1000 E CESAR E CHAVEZ AVE	90033	14	130-5A219   6	5410007022	M1-2D-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.0541	-118.22573	PLAN CHECK FOR ENERGY ONLY FOR EXISTING OFFICE SPACE TI. TOTAL SQUARE FT 4256.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28608	18041-10000-25871	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.04797	-118.25815	"TI FOR NEW RESTAURANT ""JOEY"".  Full Plan Check for power and energy. 7440 sqr Ft."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28609	10041-10000-06453	2402 E ANAHEIM ST	90744	15	030B213   113	7440002***	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	33.78054	-118.23195	refeeding a300HP, a 250HP , and a 700HP pump motors in Class I  dIV 2 LOCATION. Originally, the pump motors were supplied from a 1000A 4160V 3ph switchgear; they will now be supplied from an existing  2000A 4160V 3ph switchgear	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28610	18041-20001-27024	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS RVISING SINGLE LINE DIAGRAM FOR THE RELOCATION FEED OF PANEL IDF-4A, FROM PANEL KA TO AN EXIDTING PANEL RL, AND REMOVAL OF FIRE CONTROL ROOM PANEL. ALL CHANGES ARE CLOUDED UNDER DELTA 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28611	15041-20000-34003	2490 N FLETCHER DR	90039	13	151-5A209 278	5437033033	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM			PC Approved	10/26/2015 12:00:00 AM	ADDRESS	34.10745	-118.25455	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (RESTAURANT/OUTDOOR CANOPY). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 659 SQ. FT. PERMIT FEES PAID UNDER PCIS# 15041-20000-32533	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28612	17041-30000-01872	2134 W SUNSET BLVD unit D	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM			PC Info Complete	04/25/2017 12:00:00 AM	ADDRESS	34.07723	-118.26485	Title 24 plan check.  Change of use from restaurant to take-out restaurant.  New lighting and kitchen equipment fed from existing subpanels.  Total area = 532 sq. ft.Building permit number 17016-30000-01081	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28613	12041-10000-19719	4236 S CHASE AVE	90066	11	108B157   535	4231010022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	33.99343	-118.42947	Plan check for new roof mounted 3.43KW photovoltaic system (Enphase M215 microinverter). Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28614	19041-20000-04270	758 N CAHUENGA BLVD	90038	13	141B185   271	5533032001	CM-1VL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.0851	-118.3286	new commercial building serice < 400 amps plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28615	15041-30003-01167	6944 S KNOWLTON PL	90045	11	102B173   375	4103013008	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			09/07/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	33.97371	-118.37115	09/07/2017 Changes to permitted set of plans. Changes include revised lighting and power plan for typical unit 211. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28616	13041-10001-35796	2595 S HOOVER ST	90007	8	123A201    42	5055022034	C4-1VL-O, QC1.5-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM			PC Approved	08/29/2016 12:00:00 AM	ADDRESS	34.03206	-118.28429	Plan check for power only.  Changes to approved set.  Changing 47 conductors from copper to aluminum.  Voltage drop calculations updated. Changes apply to delta 1 only BUILDING P # 1301010000-04326	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28617	10041-10003-24242	11055 W CUMPSTON ST	91601	4	174B173  1242	2350003009	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			03/18/2015 12:00:00 AM			PC Approved	04/02/2015 12:00:00 AM	ADDRESS	34.17012	-118.37213	"Change to approved set by  upsizing the feeder for apartment units, Title-24 also being revised and  fixture  being replaced; all changes will be clouded, and under delta-6 & 7 only.(((Plan check extension variance has been filed. Original approval is on 10041-20000-24242; permit is on this application. /////////////////Permit is under ""inspection"" fee period.///////////////////////////////////////////////////////////////////////////////////////////////Expiration of Plan check. Resubmittal. PLAN CHECK FOR NEW 25 UNIT APARTMENT BUILDING WITH 1600A SERVICE. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.)))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28618	15041-20001-39918	16130 W ROYAL OAK ROAD	91436	5	162B141    89	2286016015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.14212	-118.48322	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 17.92 KW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28619	18041-20002-25855	19519 W ROSCOE BLVD	91324	12	192B117   729	2783009009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.22064	-118.5584	Revisions to approved set of plans. Revised panelboard detail - split bus panel for disaggregation compliance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28620	15041-10000-23870	5835 N FIGUEROA ST	90042	1	151-5A229  80	5492012025	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	ADDRESS	34.11069	-118.19106	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1660PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-10000-07495.THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28621	11041-20000-05080	215 W 5TH ST 1st Floor	90013		129A211    77	5149024005	[Q]C4-4D-CDO		Central City	Downtown Los Angeles			Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.04788	-118.25017	"Plan check for Walgreen for new panels, branch circuits, and lighting.  Plan check for power and energy.  Note: Core and Shell approved plans submitted for reference only.*****Remodel to an existing high rise building with 88 units adaptive reuse.  New services, switchboards, emergency generator, panels, and branch circuits.  Install general/emergency lighting.  File variance for separate fire alarm plans.  EPC is for power and energy.  ""COMPLY WITH DEPARTMENT ORDER effective date 08/04/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  Existing permit issued on application number 09041-10000-15831.  A new plan check was generated due to redesign. *****"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28622	17041-20000-17309	17540 W PARTHENIA ST	91325	12	195B129   455	2787027007	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.22845	-118.51706	Plan check for roof-mounted solar pv system on a SFD.10.4kW ungrounded system. (33) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28623	14041-10000-18992	1920 W SANTA CRUZ ST	90732	15	018B189   222	7559009017	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	33.74418	-118.31657	INSTALL 4.968 KW AC ROOF-MOUNTED MICRO INVERTER SOLAR ARRAY ON A SINGLE FAMILY HOUSE .23 MODULES23 MICRO INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28624	16041-20000-14400	12613 W VENICE BLVD	90066	11	111B153   373	4246028001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Expired	05/25/2018 12:00:00 AM	ADDRESS	34.00231	-118.4369	Fire alarm plan check only. New fire alarm system for art gallery. New FACP and 8 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28625	17041-10000-16762	20751 W MARILLA ST	91311	12	201B109   151	2748004043	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Issued	01/17/2018 12:00:00 AM	ADDRESS	34.24825	-118.58596	PC FOR POWER. SERVICE UPGRADE TO 2000AMP 120/208V 3 PHASE, 4 WIRE, ADDITION OF 2 NEW 200AMP PANELS AND 4 TRANSFORMERS. (E)COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28626	15041-10007-06920	1516 N SAN PABLO ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	34.06268	-118.20282	PC FOR ADDITIONAL LIGHTING IN SHELL SPACE. PROVIDED UPDATED T24 AND NEW CIRCUIT. CHANGES NOTED DELTA T.1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28627	19041-10001-04448	15015 W CORONA DEL MAR	90272	11	123B129   637	4411024007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM			Reviewed by Supervisor	02/12/2019 12:00:00 AM	ADDRESS	34.03183	-118.52283	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28628	10041-10000-09640	6933 W HOLLYWOOD BLVD STE  D	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	ADDRESS	34.10171	-118.34135	FIRST  TENANT IMPROVEMENTS: PARTITIONS, CEILINGS, FINISHES, NEW MEZZANINE FLOOR AND STAIRS; ADD FLOOR WITHIN (E) TWO STORY PORTION OF BUILDING TO CREATE A THREE STORY BUILDING. PARTIAL PERMIT WAS OBTAINED AS ELECTRICAL CONTRACTOR  WAS GIVEN PART OF THE WORK TO BE DONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28629	14041-10000-04675	15053 W WYANDOTTE ST	91405	6	186B145   705	2221015028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.20312	-118.4613	PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2)TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(42) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28630	14041-10000-06866	1150 S OLIVE ST 22ND FLOOR-SOUTH SIDE	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	ADDRESS	34.03962	-118.26181	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY, NEWLY CONNECTED LOAD <400 A. 22ND FLOOR. SOUTH SIDE.5070 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28631	17041-10000-42231	6703 W MELROSE AVE	90038	5	141B181   558	5524013031	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.08359	-118.33985	ADDITION TO EXISTING RESTAURANT WITH OUTSIDE DINING. NEW SERVICE, PANELBOARDS, AND CIRCUITS.FULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28632	12041-10000-01654	16221 W MULHOLLAND DR LEVEL  1	90049	5	159B137   413	2293017001	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Approved	01/24/2012 12:00:00 AM	ADDRESS	34.13027	-118.48588	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT ON LEVEL 1. NURSERY AREA AND RESTROOM. EXISTING EMERGENCY GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28633	14041-10000-02164	1800 CENTURY PARK EAST 10TH FLR-RESTROOM	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	PIN	34.06270629	-118.4150769	T24 PART 6 ENERGY PLAN CHECK ONLY FOR 364 SQ FT RESTROOM IN HIGH-RISE BUILDING. WORK WILL BE PERFORMED ON 10TH FLOOR, WITH EMERGENCY LIGHTING FED VIA (E) EMERGENCY CKT. SCOPE OF WORK < 400A. PERMIT IS EXISTING PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28634	16041-20000-27247	6527 N FRANRIVERS AVE	91307	12	180B089   591	2034018011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.18893	-118.65438	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.72 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28635	13041-10000-21756	23119 W BURBANK BLVD	91367	3	174B097   479	2041012016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.17208	-118.63054	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. SYSTEM SIZE IS 8.33 KW DC AND 7.6 KW AC. USING 34 MODULES AND 2 INVERTERS. TRANSFORMERLESS/UNGRONDED. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: SOLAREDGE # SE38000A-US[	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28636	13041-10001-32803	630 W HARRY BRIDGES BLVD Main Bldg	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	33.77068	-118.26868	[][][ CHARGES FOR RESTAMPING (DUE TO DIFFERENT LICENSING # FOR SAME DESIGNER; RON MAYLE), VERIFYING NO CHANGES WERE DEVIATED FROM ORIGINAL SET ; LICENSE # CHANGED FROM 802591 TO 986047 . PL, 12/18/13 [][][NEW FIRE ALARM SYSTEM FOR PORT OF LA - TRA-PAC-ADMIN BUILDING. TOTAL AREA IN SCOPE OF WORK PROJECTED TO BE 25,480 SQ FT, WITH 169 DEVICES, (1) FIRE ALARM CONTROL PANEL. 4-STORY ( + ROOF ), SPRINKLERED BUILDING.EXISTING PC# UNDER: 12041-10001-18057	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28637	16041-10000-19323	1700 E BAY ST	90021	14	123A215    24	5166030011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.0314	-118.23641	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 14577 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28638	15041-10000-40252	13274 W FIJI WAY ste 250	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	33.97902	-118.43558	PC for energy only, Title 24. Adding New lighting and receptacles to a commercial building (offices). Scope of work is being done at suite 250. Sq ft = 2055	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28639	18041-20000-00136	12015 N MIRABEL WAY	91326	12	216B109   170	2701081019	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Issued	01/02/2018 12:00:00 AM	ADDRESS	34.29099	-118.58237	pv1install roof mounted pv system sized sized 4.8kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28640	16041-20000-08610	8120 N WOODMAN AVE MOB5	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.21871	-118.43098	Plan check for power and energy. Project site is an existing medical office building. Project scope is a tenant improvement. Work includes the creation of (2) new exam rooms and (1) audio booth room. Total lighting area = 311 sq. ft.Note: Building application has been generated under 16016-20000-05372	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28641	15041-20001-33911	16890 W ENCINO HILLS DR	91436	5	162B133   271	2287016067	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	34.13759	-118.50105	PV1, roof mounted solar panel 14.31 kW DC, (54) modules: Q.PRO BFR-G3 265, (2) Inverters: SB6000TL-US, (2) combiner boxes	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28642	10041-10002-04198	11150 W SANTA MONICA BLVD # 100	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM			PC Approved	05/20/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	Delat 3 modification only to previously approved set of plans.  The change is to show a normal and an emergency circuit for the exit signs, and that the emergency lights are supplied from the emergency panel in the building. See circuit EP3A-1 of the emergency panel.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28643	19041-10000-10823	11401 N PORTER RANCH DR BLDG 1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.2779	-118.57107	This is supplemental plan check only, permit is covered under master #17041-10000-23328.  Add 13 new branch circuits for the pavilion area, this branch circuit count has been included with permit fee; add Jbox for wireless remote water heater in each dwelling units.The plan covers 10 Building:Build #1 through 10: 17041-10000-23328/ 23338/ 23340/ 23334/ 23336/ 23341/ 23326/ 23337/ 23342/ 21873  <<Plan check for power.  New 3 floor 33 unit apartment with 1600 amp 208 volt service.       Building 1 of 10.  Type III.       Building permit #17010-10000-02377>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28644	15041-20001-19728	22963 W CASS AVE	91364	3	168B097   552	2074010036	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.15551	-118.62106	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (49) modules, (49) power optimizers, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28645	18041-10000-37147	20929 W VENTURA BLVD UNIT 35	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	new panel and ckts in exisiting retail spacePLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28646	13041-20001-06211	1016 N COLE AVE	90038	13	144B185   888	5533015018	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.08942	-118.32972	Changes from previously approved plans.  Changes include relocate heat pumps and some lighting.  Plan check for power and energy.*****Previous Description****REMODEL AND 2,593 SF EXPANSION OF A HEALTH CLUB.  NEW 800 AMP SERVICE, LIGHTING, LOADS.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28647	18041-10000-12402	7720 N AIRPORT BUSINESS PARK WAY	91406	6	189B137   124	2205009093	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.21104	-118.49518	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURE AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28648	17041-20000-39356	700 WORLD WAY space 3158	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. RESTAURANT. 950 SQFT.Note: Building application has been generated under 17016-10000-32706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28649	14041-20002-14146	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.0352	-118.45736	[[1/29/15  CHANGES TO APPROVED SET PER INSPECTORS REQUEST TO UPDATE PLANS. REMOVING DISCONNECT SWITCH FOR THE OPTIONAL STANDBY EMERGENCY GENERATOR ONLY . DELTA 6 CHANGE ONLY]]]]]CHANGES MADE TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 5. LITTLE CHANGE TO POWER PLANS. THIS APPLICATION IS FOR RECHECK FOR CHANGES TO T24. PLAN CHECCK ONLY APPLICATION FOR DELTA 5 REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28650	18041-10000-45987	1513 W 216TH ST	90501	15	051B193   762	7349027020	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	33.83263	-118.3043	PV2. NEW ROOFTOP SOLAR WITH SYSTEM SIZE OF 5.490 KWpDC CONSIST OF 18 MODULES USING P300 OPTIMIZERS, 1 INVERTER 5KW(SOLAREDGE SE5000H-USRGM).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28651	13041-10000-19472	4840 W GLENCAIRN ROAD	90027	4	153B197   336	5588013019	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	09/03/2013 12:00:00 AM	ADDRESS	34.11416	-118.29591	PV1 7.7 KW 240V MICROINV 1 STORY. STD. ROOFMOUNT.[( 36 ) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: LG 260SICG3 ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28652	18041-10000-38763	12928 W SHERMAN WAY	91605	2	183B161    47	2327018072	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.20093	-118.41462	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28653	10041-10000-12657	263 W WORLD WAY	90045	11	087B165    13	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	08/26/2011 12:00:00 AM		Permit Finaled	12/26/2014 12:00:00 AM	PIN	33.9331766	-118.39750919	NEW UNMANED ELECTRICAL METER BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28654	16041-20000-20975	3415 S SEPULVEDA BLVD 4th floor-Restroom	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.02055	-118.42347	Plan check Title 24 only in existing rest room space T.I. in 4th floor.  Total area: 290 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28655	13041-20001-32466	22839 W DOLOROSA ST	91367	3	174B097   712	2042002010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM			PC Approved	11/27/2013 12:00:00 AM	ADDRESS	34.17023	-118.62473	PV1 MICROINVERTER. MAIN BUS IS 400A. 6.8KWAC. 26 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28656	15041-20001-10131	11054 W CASHMERE ST	90049	5	138B149   250	4366025005	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.07115	-118.45613	EXPEDITE PER APPLICANT REQUEST********Plan check for PV1 roof mounted 13kW system with 44 modules(SUNPOWER SPR0327-NE-WHT-D) and 2 inverter(SAM AMERICA-SB8000US, -SB5000TL0US-22)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28657	12041-20000-29744	1233 N MCCADDEN PL	90038	4	144B185   208	5532005040	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Approved	12/10/2012 12:00:00 AM	ADDRESS	34.09379	-118.33758	Plan check for energy only. No emergency lighting. Classrooms in a private school. 2504 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28658	19041-10000-43824	9055 N FORBES AVE	91343	12	198B133   643	2688025054	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.23545	-118.50011	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 11.34KWac USING 36 PANASONIC VBHN335SA17 MODULES AND 36 ENPHASE IQ7X MICROINVERTERS. CONNECTED TO A 225 AMP NEW SERVICE. NEW SERVICE UPGRADE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28659	16041-10000-12681	2633 S LA BREA AVE	90016	10	123B181  1192	5049013021	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.03152	-118.35178	PV1, rooftop solar 3.8 kW AC    (12) SPR327NE-WHT-D      (1) SMA SB3800TL-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28660	18041-10000-38933	1999 S AVENUE OF THE STARS 24TH	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Issued	11/13/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PC FOR T-24 ENERGY ONLY FOR OFFICE TI FOR MORGAN STANELY ON THE 24RD FLOOR. TOTAL AFFECTED AREA 8760 SQ.FT SCOPE INCLUDES EQUIPMENT, CIRCUITS AND LIGHTS. B#18016-10000-25346	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28661	15041-20000-01804	2531 S AMHERST AVE	90064	11	120B149   373	4257023049	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.0258	-118.44872	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.Note: Solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28662	19041-10001-23799	10330 W ROSSBURY PL	90064	5	123B161    31	4318026009	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM			PC Approved	08/07/2019 12:00:00 AM	ADDRESS	34.03722	-118.40964	Plan check only. Changes to an approved set of plans, changes include the re location of inverter and AC disconnect. See clouded areas on plans. _________________________________________(ePlan) PV1  Roof mounted solar 7.6 kW system. Install (20) modules with (20) P400 optimizers, (1) 7.6 kW Inverter. PV connects to (E) 200A MSP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28663	13041-10000-35682	14738 W BLACKHAWK ST	91345	7	204B149   186	2648010007	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.25803	-118.45366	PV1, Install 4.5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (18) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28664	13041-20000-20509	17341 W TENNYSON PL	91344	12	222B133   404	2602012007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.30364	-118.51183	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.9 KW. 15 MODULES AND 1 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28665	15041-10000-31644	719 E 25TH ST	90011	9	120A209   250	5131023022	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			Plans on Hold	09/30/2015 12:00:00 AM	ADDRESS	34.02228	-118.26008	PV1, INSTALL NEW 3.18 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD--US-Z-AOn hold per applicant request , refund to be filed.  NM	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28666	17041-20001-16345	6801 W HOLLYWOOD BLVD suite 147	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.10229	-118.33907	08/18/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to the lighting and power floor plans. All changes have been reflected onto the Title 24 Compliance Forms and the panel schedules.(((*****Previous Work Description*****PC for power and energy for new footlocker TI. Scope includes adding new circuits, lights, one 45KVA , equipment, transformer, and four new panelboards.Total area 15277 sqft.Building # 17016-40000-11360)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28667	11041-10001-20284	9225 S AVIATION BLVD	90045	11	093B173    59	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM			PC Approved	06/28/2012 12:00:00 AM	ADDRESS	33.95196	-118.37721	Revision to approved plans. Changes to AC side interconnection to utility service. Service to building plan check under 11041-10000-00980.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28668	15041-10001-26235	4800 S CENTRAL AVE	90011	9	111A209    93	5107019001	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM			PC Info Complete	04/29/2016 12:00:00 AM	ADDRESS	33.99967	-118.25626	UPDATE SCOPE OF WORK. NEW LIGHTING PC FOR T24. RELOCATED PANEL BOARD. PERMIT TO BE ISSUED FOR PANEL. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28669	10041-10001-22790	1467 W SUNSET BLVD	90026										Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.07552	-118.25402	REVISIONS TO PERMITTED SET OF PLANS:RESTROOMS MOVED OVER TO EXISTING STORAGE AREAWALK-IN COOLER EXPANDED INTO AREA ONCE OCCUPIED BY THE RESTROOMSSECOND COOLER DELETED AND PANELBOARDS RELOCATED TO THIS AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28670	14041-20000-31034	5048 N SHIRLEY AVE	91356	3	171B117   452	2175033007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.16233	-118.55683	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 19.6 DC.(60) SUNPOWER 327W(1) SMA SB8000TL(1) SMA SB10000TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28671	11041-10000-11970	3415 S SEPULVEDA BLVD SUITE-460	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM			PC Approved	06/10/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	TI TO SUITE 460 ON THE 4TH FLOOR OF A HIGH RISE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.  Over the Counter PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28672	13041-20000-33360	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016021	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Apartment			11/27/2013 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.08758	-118.34425	New 179-unit apartment building in Methane Buffer Zone.  Install two new services, 2500A and  2000A, panels and lighting.   Plan check for power and energy.Note: Variance to separate fire alarm submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28673	16041-20000-28118	21650 W OXNARD ST SUITE 350	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. SUTIE 350. 7863 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28674	18041-10000-33935	2120 S ESTRELLA AVE	90007	1	123A203    82	5124032020	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Expired	06/10/2021 12:00:00 AM	ADDRESS	34.03256	-118.2761	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28675	14041-10000-32387	1537 N NORFOLK ST 6th Floor	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.06138	-118.20223	14,767 sq. ft. opthalmology clinic remodel on 6th floor of existing medical office highrise building - lighting and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28676	17041-10002-35453	10957 S CENTRAL AVE	90059	15	088-5A209 260	6071020001	MR1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM			PC Approved	11/07/2018 12:00:00 AM	ADDRESS	33.93558	-118.2544	Delta4 change. adding a receptacal circuit and updating existing panels (no work done to existing panels).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28677	13041-20000-06056	643 S SPRING ST	90014	14	127-5A211 343	5144002152	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM			PC Approved	03/07/2013 12:00:00 AM	ADDRESS	34.0451	-118.25199	energy plan check restaurant renovation	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28678	19041-20001-41438	8167 S ZITOLA TER	90293	11	096B153   544	4115006012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	33.95972	-118.44369	10/31/19CHANGES TO APPROVED SET RELOCATION OF SOLAR LOAD CENTER.<<<Plan check for PV roof mounted system, PV system size: 14.0KW DC, 12.73KW AC CEC with 35AC Modules, sub-panel connected to MSP>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28679	16041-20000-21210	10345 W DIAMOND ST LOT 9	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28680	12041-10000-28734	1801 S FIGUEROA ST	90015	9	124-5A205 281	5126002008	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2242.00	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Expired	12/24/2014 12:00:00 AM	ADDRESS	34.03524	-118.27179	FIRE ALARM SYSTE FOR DOWNTOWN LA MOTORS. ADDING 1FIRE SUPRESSION PANEL AND 19 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28681	11041-20000-11895	8736 N CANBY AVE	91325	12	195B125   748	2769025016	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	ADDRESS	34.22975	-118.53467	Phase II - Intall general/emergency lighting in server room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28682	19041-10000-47417	720 E INDIANA AVE	90291	11	111B145  1209	4239007022	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	33.99772	-118.4662	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.78KWdc / 3.80KWac. ALSO, ADDING TWO TESLA POWERWALL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28683	16041-10000-29397	5051 W RODEO ROAD	90016	10	120B177  1408	5046013006	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.02173	-118.35358	PC FOR CHANGE OF USE FROM OFFICE TO STORAGE BUILDING. ALL SERVICES TO REMAIN. RENOVATING INTERIOR. PROVIDING NEW POWER, LIGHTS AND SOME NEW PANELS AND TRANSFORMERS. PC FOR POWER AND ENERGY. LOADS GREATER THAN 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28684	14041-10000-31114	3335 S FIGUEROA ST	90007	9	120A203   503	5123009042	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.02224	-118.28008	Title 24 plan check only.  Total area = 1,602 sq. ft.T.I. to existing commercial space.  Installation of new lighting, recepticles, and a 400A panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28685	14041-20001-10281	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	Plan check for modifications to approved set. Circuits/Areas changed are clouded. Add loads to panels, change area of some circuits.[PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR NONHIGHRISE BUILDING.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28686	15041-20000-39931	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.23911	-118.3725	PLANCHECK FOR POWER AND ENERGY.  BUILDING 1. WAREHOUSE DISTRIBUITION FOR XEBEC REALITY.  NEW 600 A 480Y/277V SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28687	11041-10002-27253	10460 W PICO BLVD	90064	5	126B161   413	4318001900	OS-1XL-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM			PC Info Complete	12/12/2012 12:00:00 AM	ADDRESS	34.04535	-118.41824	INSTALL A NEW 250KW, 480V, 3PH, 337AMP INDUCTION GENERATOR IN A HAZARDOUS METHANE LOCATION.   <LOCATION OF INSTALLATION:  HILLCREST BEVERLY OIL>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28688	14041-20001-02595	20911 W ARCANA ROAD	91364	3	166-5A109 201	2172022070	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.14939	-118.58885	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28689	19041-20000-00014	16133 W VENTURA BLVD 210	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.15675	-118.4847	Plan check for Title 24 only in existing restaurant space Tenant Improvement. Total area: 1213 sq ft. B#18016-10000-09740	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28690	18041-10000-01500	777 W COLORADO BLVD	90041	14	163-5A231 101	5709002018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.14074	-118.1832	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 23925 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28691	10041-20001-10055	14444 W TITUS ST	91402	6	192B149   534	2212003011	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	34.21966	-118.44792	Revision to approved plans. Upgrade 600 A service to 800A, new 800A switchboard, and new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28692	15041-10001-40938	3951 W INGRAHAM ST 1-13	90005	10	132B193   120	5092030023	R4P-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	34.06079	-118.31303	PLAN CHECK FOR LOST SET OF PLAN - NEW FIRE ALARM SYSTEM 120 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28693	11041-10000-22138	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	03/19/2012 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	33.79173	-118.23549	TESORO, new underground 2.4 KV line.  Partially in the cities of Carson, Alhambra, and LA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28694	18041-10000-01203	2009 S WESTERN AVE	90018	10	126B193  1136	5073030900	PF-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.03831	-118.30923	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28695	11041-20000-01775	10823 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.2668	-118.52366	Install site lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28696	14041-20001-12943	7621 N ASHTON CT	91304	12	186B089    90	2027040007	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.20946	-118.65	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 9.47kW(1) Power-One PVI-4.2-OUTD-S-US-A transformerless inverter(1) Power-One PVI-6000-OUTD-US-A transformerless inverter(44) ET Solar ET-P660250BB pv modules - arr. in 5 strings]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28697	16041-20001-19165	7700 W SUNSET BLVD	90046	4	147B177  1007	5551023023	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	34.09788	-118.35739	PV2.  Installation of 82.8 kW AC rooftop mounted PV system.  (363) modules with (6) 10.0 kW and (3) 7.6 kW transformerless central inverters and power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28698	14041-10001-16954	2716 W SAN FERNANDO ROAD	90065	1	150B213   144	5457003019	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM			PC Approved	02/27/2015 12:00:00 AM	ADDRESS	34.1097	-118.24272	Changes to approved set.  Change of fixture models.  Updated Title 24 Part 6 forms.  (((REMODELING OF A BAKERY IN A GROCERY STORE AND PRODUCE SECTION. THE SCOPE OF WORK INCLUDES LIGHTING, TITLE 24 ENERGY, AND EMERGENCY LIGHTING.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28699	13041-10000-02969	13764 W ALDERGROVE ST	91342	7	231B153    86	2582007003	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.32638	-118.43389	PV1 for two story house. Total system size 11.03 KW DC. {Inverter used: Power one. Model#: PVI-3.6-OUTD-S-US} {Inverter used: Power one. Model#: PVI-6000-OUTD-S-US} {Solar Module used: Yingli Energy. Model#: YL245P-29B 245W}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28700	16041-20001-45686	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	04/07/2017 12:00:00 AM	ADDRESS	34.01303	-118.24279	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28701	13041-10001-31002	21900 W PLUMMER ST	91311	12	198B105    36	2746013017	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.24254	-118.60423	Expedited RSES plan check per applicant request.(((PV2.Installing of solar array roof-mounted system for commercial building .Size 63 kW DC.1 inverter AE 50TX 600v PV DC INPUT. 252 modules HYUNDAI HIS_M250MG POLY.18 strings.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28702	16041-10002-41785	1882 S COCHRAN AVE	90019	10	126B177   720	5067020018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2017 12:00:00 AM			Reviewed by Supervisor	09/13/2017 12:00:00 AM	ADDRESS	34.04209	-118.35452	Supplemental PC for revisions to rooftop solar system. Decreasing by 20 ac modules, changing module type and reducing system to 5 strings. New system size is 18.72 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28703	11041-20000-24324	1807 S BEVERLY GLEN BLVD 1-12	90025	5	132B157   730	4317001042	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			11/14/2011 12:00:00 AM	11/15/2011 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.05666	-118.42393	New fire alarm for apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28704	18041-20000-03613	1135 N MANSFIELD AVE FLR 4	90038	4	144B181   376	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Info Complete	02/01/2018 12:00:00 AM	ADDRESS	34.0918	-118.34057	PLAN CHECK FOR TITLE 24 ONLY FOR (OFFICE TI ON 4TH FLOOR) - TOTAL AFFECTED AREA = 7684 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28705	14041-20000-24413	22720 W INGOMAR ST	91304	12	189B097   952	2013032005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.2117	-118.6223	PV1INSTALL ROOF MOUNTED PV SYSTEM.  STANDARD PLAN CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28706	11041-10000-12736	701 W WORLD WAY PKG STRUC-# 701	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/26/2011 12:00:00 AM	PIN	33.94386803	-118.39979044	REPLACEMENT OF 4 ELEVATORS IN PARKING STRUCTURE 701 AT LAXPLAN CHK IS REQUESTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28707	17041-10000-15632	815 E 95TH ST	90002	9	093A209    42	6050011019	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	33.95034	-118.26025	PC FOR PV ROOF MOUNTED PV ON SFD. TOTAL SYSTEM SIZE  7.6 kWACSYSTEM INCLUDES SOLAR EDGE  SE-7600-US22 CANADIAN SOLAR CS6U-340M22 SOLAR EDGE OPTIMZERS P-400	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28708	17041-20002-43978	18237 W LOS ALIMOS ST	91326	12	207B125   200	2715010021	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Issued	06/19/2018 12:00:00 AM	ADDRESS	34.26557	-118.53125	"06/19/2018 Changes to an approved set of plans. All changes have been clouded. Electrical equipment has been relocated and recircuited. There was an addition of (1) new load center. *****Previous Work Description*****""20.55$ permit fees due to senate bill 1222""PV1.  Install 11.05 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (34) modules."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28709	14041-20000-20118	823-829 W EXPOSITION BLVD harris-hall	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM			Corrections Issued	07/25/2014 12:00:00 AM	ADDRESS	34.01842	-118.28748	Plan check for energy only. USC Harris Hall first floor, demo old track lighting, install new track lighting in place. New track also installed above stairs. 5,911 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28710	12041-10001-15345	3023 S BAGLEY AVE	90034	5	123B165   503	4311019005	R1-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.0341	-118.39498	Plan check for new 3.6KW roof mounted photovoltaic system using Solaredge transformerless inverter and DC-DC Power box. Existing permit #12041-20000-15345 for modules and inverter,  Misc Permit on this application is for the DC/DC Inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28711	17041-10000-18464	9110 N VAN NUYS BLVD	91402	6	198B149   535	2639008025	[Q]C2-1VL, [T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.23602	-118.45005	Title 24 plan check.  Remove HID fixtures and replace with LED. TOTAL OF 20 FIXTURES. TOTAL AFFECTED AREA 81140SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28712	15041-20002-43998	16654 W WYANDOTTE ST	91406	6	186B137   344	2226016009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.20282	-118.49652	[[2/9/16 CHANGES TO APPROVED SET. REDUCING MODULES FROM 20 TO 16 AND CHANGES IN SINGLE LINE DIAGRAM]]]]PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.7 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28713	11041-10000-11482	11900 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM			Reviewed by Supervisor	06/21/2011 12:00:00 AM	ADDRESS	34.28642	-118.50125	NEW SERVICE AND COMPLETELY NEW ELECTRICAL SYSTEM FOR AN EXISTING GROCERY STORE BUILDING.  CUSTOMER WILL BRING IN MISSING T-24 SHEETS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28714	14041-10000-03388	970 W 190TH ST UNIT #425	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	33.85812	-118.29302	T24 PART 6 ENERGY FOR HIGH RISE OFFICE BUILDING. SCOPE OF WORK < 400A, PLAN CHECK FOR ENERGY ONLY. AREA IS APPROX. 3196 SF.  PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28715	17041-10000-22139	10671 W LORNE ST	91352	2	189B177   205	2407012019	MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.2166	-118.36373	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28716	12041-20000-08163	808 S SPRING ST	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			04/10/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.04272	-118.25371	Fire alarm system for a high-rise apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28717	14041-20000-17453	13330 W RIVERSIDE DR	91423	4	168B157   334	2359023003	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.15738	-118.42406	Plan check for energy only. Install new lighting (incl. emergency) in 2-story classroom building. 6334sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28718	16041-20002-02147	14545 W VENTURA BLVD	91403	4	166-5A151  95	2265010004	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.15135	-118.45029	03/01/2016 Changes to an approved set of plans. Changes include revisions to the lighting floor plan and the power plan.*****Previous Work Description*****02-09-2016 Change to approved set of plans, Changes include removed 4 lighting fixtures(1x4 LED)and replace with  Recess LT LEDs and Pendent LT. Changes apply to delta 1 only(((((((TI to existing commercial building. Plan check for energy only. Adding new lighting (incl. emergency). Total sqft. 682.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28719	15041-10000-37695	6180 S ST ANDREWS PL	90047	8	105B193   733	6001017010	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	33.98359	-118.31134	T24 only. remove HID light fixtures and replace with new LED fixtures. Total area 18524 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28720	13041-10000-32173	12883 W RUNWAY ROAD UNITS 1-3-BLDG 6	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/26/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	33.97519	-118.42049	INSTALLATION OF A NEW FIRE ALARM SYSTEM for a 4 story residential building (Building 6). THIS IS BUILDING 6 OF 6.  THE FACP IS ON BUILDING # 2. There are two building types for the site. Building 6 plan is type 3 ( SIGNIFYING 3 PLEX ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28721	11041-20000-20748	13640-13648 W FOOTHILL BLVD	91342	7	222B157    94	2509014014	(T)(Q)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.3076	-118.43089	office/fitness centerBldg. permit 10010-20000-01691	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28722	12041-20000-24233	23407 W SCHOOLCRAFT ST	91307	3	183B093   516	2028013027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2012 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.19531	-118.63868	PV solar installation in single family dwelling. N-phase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28723	19041-10002-09100	14987 W ORO GRANDE ST	91342	7	219B149   512	2604033009	RE9-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	34.29647	-118.45801	Plan check only. DELTA 1 CHANGES TO AN APPROVED PV SET. ADDITION OF A PERFORMANCE METER AND UPDATE PLACARD VALUES FOR DC DISCONNECT. Original scope of work: (( NEW ROOF MOUNTED 12.2KW PV SYSTEM WITH 40 PV PANEL(Q.Peak-G4.1 300-305) ON  A SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28724	16041-10004-04795	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.0631	-118.36086	{This is plan check only, no supplemental permit is needed} Revision to approved set of plan noted as FRI-M1345. Revision to Single Line Diagram to show the physical separation of the Generator from Dist. Board EMSB as installed on the field.PC FOR POWER AND ENERGY.  ADD THEATER STRUCTURE TO (E) MUSEUM/RESTAURANT/RETAIL/OFFICE BLDG. 2 NEW SERVICE WITH 3000A, 5000A , ADDITION OF NEW PANELS AND DEVICES. B# 13014-10000-03762	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28725	14041-20000-26966	19958 W VANOWEN ST	91306	3	180B113    35	2134012024	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Expired	10/25/2016 12:00:00 AM	ADDRESS	34.19365	-118.56863	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING STANDARD PLAN. TOTAL OF 2 STRINGS COMBINED. USING TRANSFORMERLESS INVERTER. SYSTEM USES POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28726	14041-10001-24245	1601 N VINE ST	90028	13	148-5A187 301	5546009906	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.09996	-118.32693	((((4/28/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2.  CHANGES INCLUDE SIZE IN FEEDERS AND TOWER CRANE.  Temporary Power for construction.  2 Elevators 800 Amp Bus switch board 3 Transformers 75 KVA. High Rise 5 below grade 8 levels above grade core  and shell. None Mathane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28727	10041-10000-01346	10780 W SANTA MONICA BLVD floor-2nd	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Finaled	02/22/2010 12:00:00 AM	ADDRESS	34.0504	-118.43387	Tenant improvement for high rise commercial building.  Install new general and emergency lights in waiting room (201) and corridor (208).  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28728	13041-20000-28425	6330 W SAN VICENTE BLVD SUITE 270	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.06116	-118.36804	PC FOR T24 ENERGY ONLY. TOTAL AREA 2100 SQ FT. NEW LIGHTING. OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28729	12041-20000-24425	555 E RAMIREZ ST	90012	14	132A217   238	5409021900	PF-1XL	Central	Central City North			2060.20	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	34.05425	-118.2309	Plan check for fire pre-action system. 1 panel and 12 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28730	19041-20001-11929	13160 W MINDANAO WAY Ste 170	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	33.98501	-118.43726	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, REMOVAL OF PHOTOSENSORS ON LIGHTING FLOOR PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28731	18041-20000-37395	10345 W OLYMPIC BLVD 1st Floor	90064	5	129B161   114	4319006052	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.05186	-118.41853	Plan check for Title 24 only. Project site is the 1st floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,900 sq. ft. This is labeled as Package 1.Note: Building application has been generated under 18016-10000-31069	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28732	18041-20000-32899	15254 W CAREY RANCH LANE	91342	7	216B145   276	2611038002	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.28935	-118.4632	Plan check for a PV1 roof-mounted PV system. System size is 7.54 kWdc/7.6 kWac and consists of (1) inverter and (26) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28733	12041-10000-12281	11861 W LAURELWOOD DR	91604	2	162B169   365	2369027019	[Q]RD1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.14137	-118.39133	Plan check for new roof mounted 6.615KW photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28734	16041-20000-27251	6708 N BIANCA AVE	91406	6	180B129   183	2229010035	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM			PC Info Complete	08/16/2016 12:00:00 AM	ADDRESS	34.19237	-118.51298	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8 KW INTERCONNETED WITH MSP.  THIS IS TIED INTO AN EXISTING PV SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28735	17041-10000-22173	1723 S LIVONIA AVE	90035	5	129B169   976	4305023020	R1V2	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.04828	-118.38688	plan check for pv roof mounted system. Scope includes (1) central inverter-(SE6000A) with (21) modules - (SOLARWORLD SW295). TOTAL SYSTEM SIZE = 6KVA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28736	17041-10000-29493	801 W 23RD ST	90007	1	123A203    68	5124031012	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Apartment			08/18/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.03251	-118.27764	PERMIT FEE = $0.00 PER SENATE BILL 12222PC FOR ROOF MOUNTED PV ON APT BUILDING (COMM)MICRO INVERTER SYSTEM SIZE 30.3KW AC / 34.5 KW DCSCOPE INLCLUDES 106 MODULES WITH MICRO INVERTERS (IQ6PLUS-72-US)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28737	19041-20000-21757	366 S LOMA DR	90017	1	133-5A207 268	5153019010	R4-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Apartment			06/07/2019 12:00:00 AM			PC Info Complete	03/01/2021 12:00:00 AM	ADDRESS	34.05902	-118.26623	Plan check for power and energy. Project site is a 6-story, 39-unit apartment building. Work includes a 1,200 Amp service and a total lighting area of 21,513 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28738	12041-10002-26781	6148 W PICO BLVD	90035	10	129B173   180	5068001005	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			Corrections Issued	07/01/2013 12:00:00 AM	ADDRESS	34.05298	-118.37549	changes to approved set of plans: re-submittal to EPC with accurate loads, requested by inspector. Revised 1) lighting load 2) show window load 3) load in panel B 4) no 120V single phase loads allowed on panel B 5) equipment loads not accurate. system is 120/240V delta NOT 120/208Y.PC FOR power only , title 24 was approved under 12041-10000-26781.  Inspector sent applicant back for load calculation and PC power approval to make sure service is okay for the load.  Change of use from retaail to dry cleaning. changed panel B2 from single to three phase during plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28739	18041-10000-11520	6645 N TOPANGA CANYON BLVD	91303	3	180B101   256	2139006021	(WC)TOPANGA-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.19141	-118.60616	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28740	14041-10000-31666	1228 W 25TH ST	90007	8	123B197   753	5055015023	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.03344	-118.28737	PV1.  Installation of 3.597 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28741	12041-10000-31126	9340 N RUBIO AVE	91343	14	156B213   227	5459017020	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.24044	-118.49489	PV1 1 STORY HOUSE 22 MODULES [MODULES: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28742	19041-10000-38715	1506 W 61ST ST	90047	8	105B193   680	6002024900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Expired	02/01/2023 12:00:00 AM	ADDRESS	33.98447	-118.30269	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28743	15041-20000-35280	8221 W SUNSET BLVD	90069	4	147B173   195	5555030010	R4-1D	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			Corrections Issued	10/21/2015 12:00:00 AM	PIN	34.0982535	-118.3684526	Plan check for Title 24 only in kitchen area at CHATEAU MARMONT HOTEL. Total area 1,219 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28744	18041-20000-02146	17116 W LABRADOR ST	91325	12	201B133   206	2692012023	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.24967	-118.50574	permit fee $0.00 by state senate bill no. 1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.025 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28745	16041-20000-44223	8700 N TAMPA AVE	91324	12	195B117   135	2784003061	MR2-1VL, P-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.22844	-118.55337	remove existing hid fixtures and replace with new led fixtures outdoors. plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28746	11041-10000-14254	3450 S OVERLAND AVE	90034	5	120B161   657	4314019010	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.02513	-118.41168	T.I.  Existing 7-11.  Replacing existing fluorescent lights with LED lights on the retail floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28747	14041-20001-12026	12642 W SANDHILL LANE Unit #1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.97765	-118.41437	Fee for expedite only*****Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 1 of 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28748	13041-20001-10958	5700 N CANOGA AVE 2ND FLR	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.17365	-118.59715	Changes to approved set of plans.2ND FLOOR REMODEL FOR OFFICE AREA, TOTAL AREA 18,000 SQ FT. PC FOR POWER AND ENERGY. NEW CONNECTED LOAD TO EXCEED 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28749	14041-10000-06389	6051 N CARTWRIGHT AVE	91606	2	177B177   476	2414014002	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.1809	-118.36389	PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U (10)MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28750	11041-10000-10237	1643 E 103RD ST	90002	15	091-5A213 142	6048013053	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	ADDRESS	33.9448	-118.24489	TI TO AN EXISTING RETAIL SPACE.  T-24 WITH EMERGENCY, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28751	16041-10000-27157	1875 S CENTURY PARK EAST #950	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.06115	-118.41457	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING FOR SUITE 950. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 7920 SQ. FT. B#16016-10000-17307	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28752	16041-10003-36637	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019007	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Info Complete	10/26/2017 12:00:00 AM	ADDRESS	34.25776	-118.46707	PC FOR CHANGES TO APPROVED SET UNDER DELTA 31. SCOPE INCLUDES REVISIONS TO LIGHTING FIXTURE COUNT AND CALCULATIONS INCLUDING TITLE 24 REVISIONS. ALSO, REVISIONS TO LOAD CALCS. (THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28753	16041-20000-21267	10447 N GLORY AVE	91042	7	204B201   117	2565001057	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.25888	-118.28112	CHANGES TO AN APPROVED SET OF PLANS.  CHANGE MODULE TYPE FROM SILFAB SLA 275M TO SUNEDISON SE-F270KZD-3Y.  THIS IS PLAN CHECK ONLY.REFERENCE MASTER APPLICATION FOR FEES 16041-20000-15139PV1.  Install 5.4 kW DC roof-mounted PV system.  (20) 270W modules with 6000W rated central inverter with power optimizers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28754	19041-20000-16236	22526 W FRIAR ST	91367	3	177B097    23	2039025006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.1854	-118.61789	Plan check for PV roof mounted system, PV system size: 12.21KW DC, 10.378KW AC with 37 PV modules and 1 inverter(11.4KW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28755	18041-10000-41027	8954 N MASON AVE	91311	12	195B109    41	2781001039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Issued	10/26/2018 12:00:00 AM	ADDRESS	34.23371	-118.57961	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28756	18041-10000-32764	16500 W MULHOLLAND DR	90049	11	159B137   431	4490007900	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.13075	-118.49219	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28757	16041-10000-26945	7115 N SHOUP AVE	91307	12	183B101   185	2024016104	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.19951	-118.61487	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (OUTDOOR)  26460 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28758	05041-10005-27030	3434 S GRAND AVE	90007	9	118-5A203 116	5122030020	MR1-2	South Los Angeles	Southeast Los Angeles	Southeast/Central Avenue		2311.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	03/30/2010 12:00:00 AM	ADDRESS	34.01912	-118.27658	INTERIOR IMPROVEMENT AT THE USC DATA CENTER-ADDING A 750KVA UPS SYSTEM TO SWBD DC1; NOTE THAT SINGLE LINE SHOWS PROPOSED FUTURE LOADS OF 2 EA SIMILAR UPS SYSTEMS TO BE ADDED .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28759	18041-10000-02694	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Issued	07/10/2018 12:00:00 AM	ADDRESS	34.02174	-118.39786	FIRST TIME OCCUPANCY IN UNIT #103.CHANGE OF USE FROM RETAIL TO DANCE STUDIO, EPC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28760	16041-20000-14636	16637-16641 W ARMINTA ST	91406	6	189B137    30	2205009032	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.21497	-118.49579	PERMIT FEE $0.00 STATE SENATE BILL NO.1222Plan check for a PV2 roof-mounted PV Feed-In Tariff system. System size is 60 kWac and consists of (3) inverters, (246) modules, (1) load center, and (1) transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28761	18041-20000-35636	16520 W JERSEY ST	91344	12	207B137   126	2680016016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.26729	-118.49205	Plan check for a PV1 roof-mounted PV system. System size is 12.76 kWdc/10.56 kWac and consists of (44) micro-inverters, (44) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28762	16041-20001-10795	5001 W MELROSE AVE	90038	13	141B193   569	5535017007	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM			PC Approved	04/29/2016 12:00:00 AM	ADDRESS	34.08365	-118.30951	Plan check only for changes to lighting design.  Change of pendant fixture to screw-shell fixture at 60W maximum.  Current-limiters on track lighting.  (((CHANGE OF USE FROM RETAIL FURNITURE TO RESTAURANT - 1533 SQ FT.  PLAN CHECK FOR ENERGY ONLY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28763	12041-20000-02257	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.30237	-118.46212	New 3000A service for industrial building (Plant 1).  Install new switchgear, panels, equipment and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28764	17041-10000-06543	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR INSTALLATION OF 2 SUB DISTRIBUTION UNITS. PACKAGE UNITS CONTAIN TRANSFORMER AND DISTRIBUTION FOR NEW PANELS. NO LOADS AT THIS TIME.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28765	14041-20000-19861	7224 W HILLSIDE AVE 1-39	90046	4	150B181   604	5572031016	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	Apartment			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Expired	08/25/2016 12:00:00 AM	ADDRESS	34.10443	-118.34725	Installation of new fire alarm panel and one new device in (E) 4-story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28766	15041-10000-12702	19827 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	33.85047	-118.28661	T24 ONLY.  REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXUTRES. TOTAL AREA 5408 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28767	17041-10000-44215	621 S GRAMERCY PL	90005	10	135B193   949	5504027005	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Issued	12/08/2017 12:00:00 AM	ADDRESS	34.06267	-118.31298	Plan check for T24 only, replace outdoor metal halide fixtures with new LED fixtures, area: 2200 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28768	13041-10000-15727	1925 S CENTURY PARK EAST #200	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM			PC Approved	06/14/2013 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TI SUITE #200.  PERMIT SHALL BE OBTAINED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28769	15041-10001-39310	7257 W MELROSE AVE	90046	5	141B181   543	5525012011	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.08364	-118.34773	CHANGES TO APPROVED SET. NEW OCCUPANCY SENSOR IN DINNING AREA. REVISED TIME CLOCK CONNECTION. REVISED LIGHTING LAYOUT. PROVIDED UPDATED TI24 FORMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28770	19041-20001-11160	6437 N COLUMBUS AVE	91411	6	180B145   701	2235001018	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.18772	-118.46416	PLAN CHECK FOR NEW 12.24KW DC/10.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES 34 SUNPOWER 360W PV MODULES WITH INTEGRATED 320W MICROINVERTERS, (2) 125A SUB PANELS, AND AN 200A SUB PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28771	15041-10001-15506	1144 S BROADWAY	90015	14	126A209   221	5139017010	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.03859	-118.25963	Plan check for lost set of plan. for a vacant 3-stories building, new wiring and switchboard  for overhead  800A service and additional 100A service .; conduits from switchboard are stubbed-out.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28772	19041-10000-42477	12412 N NEDRA DR	91344	12	219B133   487	2609021019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.29588	-118.49876	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 9.6KWDC/9.45KVAAC PV1 SYSTEM CONSISTING OF 30 MODULES USING 30 MICROINVERTERS(IQ7X) AND ESS(TESLA POWERWALL) MAIN BREAKER DERATE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28773	15041-10001-41022	10925 N WILLOWBRAE AVE	91311	12	210B105   202	2722037009	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.26877	-118.59868	expeditePV1 SFD TOTAL SYSTEM SIZE 12 KW AC USING 2 CENTRAL INVERTERS. TOTAL OF 41 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28774	17041-20001-45360	9745 N SALOMA AVE	91343	7	201B149   384	2650006011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.24771	-118.45774	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.System size: 3.6kW ungrounded. (13) 330W pv modules.Existing 4kW pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28775	19041-20000-49494	7035 W MACAPA DR	90068	4	153B181   107	5549008012	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.11759	-118.34389	PV1 PLAN CHECK FOR NEW P SYSTEMV. PV SYSTEM SIZE IS 3.72 KW DC/3.8 KW AC. SCOPE OF WORK CONSISTS OF (12) PV MODULES WITH OPTIMIZERS AND A 3.8 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28776	15041-20000-15683	6371 W 80TH ST	90045	11	099B165   346	4109007003	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.96888	-118.39879	PV1Using standard plan.Install a roof-mounted solar array on SFD and detached garage. Interconnect with 200A MSP.System size: 6kW. Ungrounded system. (20) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28777	13041-10000-31287	6051 W HOLLYWOOD BLVD #111	90028	13	148-5A189  98	5545002033	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.10182	-118.32202	PLAN CHECK ONLY FOR T24 ENERGY ONLY. 2602 SQFT, EMERGENCY LIGHTING. 2 STORY BUILDING. WORK ON FIRST FLOOR. EXISTING PERMIT UNDER PC # 13041-10000-29952	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28778	18041-20000-37513	20718 W BEECH CIR #298	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	08/17/2019 12:00:00 AM	ADDRESS	34.29279	-118.58495	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28779	14041-20000-14134	12631 W ADDISON ST	91607	2	171B161   925	2357008004	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.16137	-118.4084	PV1 with 7.51kw roof-mounted system including (33) Hyundai HIS -S260MG module and  (2) transformerless SMA America SB4000TL-US-22 inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28780	19041-10000-47869	19246 W LUDLOW ST	91326	12	210B117   184	2718024006	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.27056	-118.55264	NEW PV1 ROOFTOP SOLAR SYSTEM CONSIST OF 33 MODULES (QPEAK DUO 320), 33 OPTIMIZERS (P320) AND 1 CENTRAL INVERTER (SE7600H-US). SYSTEM SIZE IS 10.56KWdc AND 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28781	18041-20000-31068	1421 S BARRY AVE 1-9	90025	11	129B149   527	4263020022	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.03	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	02/18/2022 12:00:00 AM	ADDRESS	34.04607	-118.4569	Plan check for power only Service upgrade 800A  to existing 9 units apartment building.B18016-10000-26284	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28782	16041-10000-37608	10250 W SANTA MONICA BLVD # 1720	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM			Permit Closed	04/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Aritzia"" Ste. 1720.  Install new 75KVA xrfm, panels and its circuits, lights and receptacles. Total effected area: 11,139 sq.ft. using performance method"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28783	18041-10000-33118	3831 W BEVERLY BLVD	90004	13	138B197   294	5520019018	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.0765	-118.29271	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28784	10041-20001-19833	8719 N BRADLEY AVE	91352	6	195B173   541	2408023017	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM			PC Approved	12/06/2010 12:00:00 AM	ADDRESS	34.22785	-118.37426	Plan check only. Plan check revision to approved plans. Revision Delta 1 from load side interconnection to line side interconnection only. Existing permit includes replacing 400A with new 400A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28785	19041-20000-08095	4965 S CENTINELA AVE	90066	11	105B161   126	4221023033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	Apartment			03/06/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	10/20/2020 12:00:00 AM	ADDRESS	33.98734	-118.41678	Plan check for power and energy. Project site is a new 3-story, 25-unit apartment building with basement parking garage. Work includes a 1,200-amp service and a total lighting area of 17,198 sq. ft.Note: Building permit has been issued under 18010-20000-02162	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28786	19041-30000-44633	11150 W OLYMPIC BLVD STE 1160	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.03956	-118.43857	Energy pc only Interior, Area of scope (3,296 SF).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28787	19041-20000-17925	23521 W TIARA ST pv1	91367	3	177B093   748	2041001005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.17837	-118.63938	pv1install roof mounted pov system sized 10KW AC interconnetced with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28788	16041-10001-15028	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	PIN	33.94094587	-118.40577128	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DCN - 002 ON PLAN. CLOUDED. CHANGES LNCLUDE USE OF BUSWAY 3200A AND REVISED FLOOR PLANS. PROVIDED UPDATED SHEETS AND T24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28789	17041-10000-01791	5343 W IMPERIAL HWY	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Closed	07/31/2017 12:00:00 AM	ADDRESS	33.93128	-118.37337	PC AND PERMIT FOR GENERATOR CONNECTION TO FEED BUILDING LOADS DURING CONSTRUCTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28790	14041-20000-00905	434 N LA BREA AVE	90036	5	141B181  1360	5525029025	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.07923	-118.34385	Change to lighting in an existing retail space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28791	12041-10000-24908	1111 W SUNSET BLVD	90012	1	136-5A211 440	5406020003	C2-2D	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			10/18/2012 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.06583	-118.24918	Renovation of an existing 103 units appartment Bldg. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28792	15041-20000-23268	13959 W WYANDOTTE ST	91405	2	186B153   652	2216001019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.20312	-118.43778	PV1. Install roof mounted PV system sized 5.0 kW. Interconnected with main service panel. (21) Kyocera KU 2656 Modules(1) Fronius PVI 5.0 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28793	16041-10000-22300	5999 W CENTER DR 3RD FL	90045	11	102B169   959	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	33.9761	-118.38876	RENOVATE THE LOBBY AND TENANT IMPROVMENT IN THE (E) OFFICE. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28794	14041-10000-16309	4508 W WAWONA ST	90065	14	160-5A219 217	5683019020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.13351	-118.22579	PV1. ROOF MOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. SYSTEM SIZE 5.23 KW. Note: Fire dept plan check not required per SA 8/19/2014. (19) SOLARWOLRD SW275 MODULES(19) M250 MICROINVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28795	14041-10000-04560	1216 E ROSE AVE	90291	11	114B145   123	4244001900	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.00586	-118.45896	(N) chemical treatment building with pumps for stormwater treatment.  New restroom building under separate building permit being subfed by feeder from treatment building.  Additional plan check hour for loads in new subfed restroom bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28796	13041-10000-23043	14615 W OXNARD ST	91411	6	177A151    96	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/23/2013 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.17955	-118.45137	EXPEDITED  THROUGH CITY BOND PROGRAM. TO BE AHEAD OF ALL NORMAL PLAN CHECKS.NEW 30 FOOT TALL HOSE-TOWER. NEW BUILDING. PLAN CHECK FOR POWER AND ENERGY.  2 STORIES. PLAN CHECKER VERIFY FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28797	19041-20000-49016	4246 N FARMDALE AVE	91604	2	165B169   755	2368018006	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.14626	-118.38103	PV1. INSTALL 8.58 KW DC PV SYSTEM WITH (26) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28798	14041-20001-35577	706-720 N CAHUENGA BLVD	90038	13	141B185   537	5533032014	C4-1XL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	34.08371	-118.32861	11/17/15changes to approve set. all changes made under delta 8. Scope includes adding site lighting. (((TI TO AN EXISTING COMMERCIAL 2 STORY BUILDING.  ADDING CIRCUITS TO EXISTINF PANELS, NEW LIGHTING AND CONTROLS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 27248.FEES ARE ESTIMATED PLAN CHECKER TO VERIFY.  CORE AND SHELL RENOVATION OF EXISTING STORE W/AXILLARY OFFICE, MANUFACTURING AND STORAGE TO OFFICE USE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28799	16041-10000-04759	2011 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.06159	-118.20463	PC FOR ENERGY. TI FOR USC BUILDING FROM THE GROUND LEVEL TO THE 9TH FLOOR. DEMOLISHING AND ADDING NEW LIGHTS AND CONTROLS AND ADDITIN OF RESTROOMS./LABS. TOTAL AREA 3963 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28800	17041-20002-18055	5123 N WILBUR AVE	91356	3	171B121   405	2161004047	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.1637	-118.54556	[[[7/11/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES CLOUDED. CHANGING ROOF LAYOUT, REMOVING TWO MODULES, CHANGING MODULE TYPE, AND DERATING MAIN BREAKER]]]]]PLAN CHECK FOR ROOF TOP SOLAR SYSTEM - SYSTEM SIZE  = 15.2KW AC CONSISTING OF TWO INVERTERS (SOLAREDGE-SE7600A-US), AND 48 PANELS (LG320N1C-G4)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28801	17041-20000-36674	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES AND BATHROOM. 2336 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28802	15041-20003-25787	8100 N WOODLEY AVE	91406	6	189B141    22	2206005012	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.21787	-118.48348	05/04/2016 Changes made to approved set of plans.  Standardized fuse ratings, elaboration of motor assemblies on SLD drawings.  (((02/11/2016 Changes to an approved set of plans. Changes have been made to address corrections made by the inspector. Changes have been clouded and marked as Delta 3, 6, and 13.*****Previous Work Description*****NEW MOTORS FOR PROCESS EQUIPMENT AT INDUSTRIAL FACILITY.  PLAN CHECK FOR POWER.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28803	17041-10001-01744	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION.  ALL CHANGES UNDER DELTA 3 THROUGH 10.SCOPE INCLUDES ADDITION, RELOCATION AND REMOVAL OF DEVICES PER ARCHITECTURAL CHANGES. TOTAL OF 15  DEVICES ADDED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28804	18041-10000-15180	200 S OLIVE ST	90012	14	130-5A211  11	5149010023	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.05352	-118.24883	REMOVE EXISTING HID FIXTURES AND REPLACE THEM WITH NEW LED FIXTURES. TITLE 24-ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28805	19041-20000-38810	11835 W OLYMPIC BLVD 825E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.03301	-118.45119	T24 PLAN CHECK FOR TI REMODEL OF A EXISTING OFFICE SPACE IN A HIGH RISE COMMERCIAL. LIGHTS NAD OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1339 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28806	18041-10000-08199	10277 W OLYMPIC BLVD	90067	5	129B161    44	4319005070	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.05329	-118.41657	FULL PC, TENEANT IMPORVEMENT TO 2ND AND 3RD FLOOR OFFICE SPACE. SCOPE OF WORK INCLUDES ADDITIOIN OF A NEW ATS  TO AN EXISITING DISTRIBUTION BOARD AND NEW CIRCUITS. TOTAL CONNECTED AMPS > 400AMPS AND SQ FT 10400.B# 17016-10000-36016	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28807	12041-10002-22197	617 W 7TH ST #604	90017	9	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.04779	-118.2571	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT FOR #604. ADDITIONAL PERMIT FOR NEW LIGHTING ON EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28808	13041-20000-00670	3616 S TROUSDALE PKWY M226	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/10/2013 12:00:00 AM			PC Approved	01/10/2013 12:00:00 AM	ADDRESS	34.01983	-118.28534	Plan check for energy and emergency lighting. 1126sqft. Allan Hancock Foundation Building Lab for Dr. Naomi Levine Room M226.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28809	15041-20002-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.25734	-118.50614	(2/2/2017)changes to an approved set of plans delta 4.  changes to reflect existing field conditions.  this is plan check only.CHANGE OF USE TO MEDICAL OFFICES. FULL TI. PC FOR POWER AND ENERGY. PER BUILDING PERMIT, PC IN ACCORDANCE TO 2008 NEC AND ENERGY CODE STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28810	12041-10000-01627	22115 W ROSCOE BLVD	91304	12	192B101   520	2010023034	(T)(Q)C1.5-1, C2-1L, P-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM			PC Approved	01/26/2012 12:00:00 AM	ADDRESS	34.21979	-118.60892	T.I. to an existing Senior Care Center.  No suite number per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28811	14041-10001-10386	11220 N TELFAIR AVE	91331	7	210B153   314	2616021062	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.27382	-118.43617	changes to approved: upgrading panel from the approved set's 125A to 200A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28812	10041-10000-25467	540 S NORMANDIE AVE	90020	4	135B197   947	5502018002	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.06411	-118.30015	NEW 66 UNITS AFFORDABLE FAMILY HOUSING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28813	15041-10000-42773	10310-10440 N SEPULVEDA BLVD	91345	7	204B145   259	2649019007	C2-1, CR-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.25776	-118.46707	T-24, ADDITION TO COMMERCIAL BUILDING AND MAINTENANCE ROOMS AND REMODEL OF EXTERIOR FACADE. SCOPE OF WORK INCLUDES NEW LIGHITNG. TOTAL SQ. FT. 3680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28814	19041-10000-17861	4910 E LA CALANDRIA DR	90032	14	138A233   192	5216014011	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/31/2020 12:00:00 AM	ADDRESS	34.07229	-118.17788	(ePlan) New Residentail rooftop 7.6 kW ACPV system with 9.3 kWh ESS. Install (1) 7.6 kW inverter, (15) LG solar modules with (15) optimizers P505, (1) 9.3 kW LG battery back up, (1) 60A panelboard. System connect to 200A MSP.Note: 200A MSP upgrade shall be under separate permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28815	17041-10000-05828	1225 S RIO VISTA AVE	90023	14	121-5A219  58	5170012003	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.02823	-118.22185	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 38750 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28816	13041-20001-18734	12451 W ALBERS ST	91607	2	174B165   875	2347002019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.17044	-118.40474	PV1 MICROINVERTER STANDARD PLAN. 32 PANELS TOTAL SYSTEM 6.9 KW.(( CHANGES TO APPROVED SET OF PLANS. ONLY CHANGE IS MODULES. SYSTEM SPECS ON AC SIDE REMAINS. ONLY CHANGE IN DC SIDE. CHANGES CLOUDED. ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28817	13041-10000-29526	2734 S NORMANDIE AVE	90007	8	123B197  1486	5054006008	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Apartment			10/23/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.02987	-118.30006	PV1 4KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(16)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28818	15041-10000-25541	811 W 7TH ST	90017	14	129A209    39	5144008008		Central				2077.10	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	34.04908	-118.25911	PC FOR FIRE ALARM SYSTEM AT A high rise FINE ARTS BLDG 12 STORIES HIGH. THE SCOPE OF WORK INCLUDES A NEW FIRE ALARM CONTROL PANEL AND UPGRADE WITH VOICE EVACUATION. (107) F A DEVICES(1) COMMUNICATION PANEL (8) CONTROL PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28819	19041-10000-30107	12101 W OLYMPIC BLVD	90064	11	123B149   452	4259019008	(T)(Q)C2-2D	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	05/13/2020 12:00:00 AM		Permit Finaled	10/05/2023 12:00:00 AM	ADDRESS	34.0325	-118.45463	FULL PC FOR POWER AND ENERGY. SCOPE OF WORK IS A  NEW 7 RESDENTIAL TOWER. SCOPE OF WORK INCLUDES A 4000A SERVICE AND A 6000A SERVICE AS WELL, AND TWO FIRE PUMPS. SCOPE OF WORK ALSO INCLUDES VARIOUS EQUIPMENT, DISTRUBTION BOARDS AND SUBPANELS.B# 19010-10000-02627	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28820	13041-20003-32813	13345 N CONSTABLE AVE	91344	12	225B133    70	2601014025	RS-1, RS-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.31272	-118.50599	Modification to approved set.  Change of combiner box model/manufacturer.  $0 submittal fee is due to Senate Bill SB-1222. (((PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 15KW. 60 MODULES AND 2 INVERTERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28821	12041-10000-10371	4160 W WILSHIRE BLVD #201	90010	10	132B189    60	5092001046	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2126.10, 2127.00	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	09/12/2012 12:00:00 AM	ADDRESS	34.06152	-118.31825	TENANT IMPROVEMENT OF AN EXISTING OFFICE INTO A MEDICAL OFFIC WHERE OUTPATIENT SURGERY IS PERFORMED. IN SUITE 201COMPLETE PLAN CHK.  Office is not state licensed and will not be in the future.  Not checked for OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28822	18041-20000-10107	3711 S WESTERN AVE 1-4	90018	8	117B193   108	5041024027	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.0206	-118.30904	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.04 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28823	15041-20000-12630	1440 S VETERAN AVE	90024	5	129B153    17	4324038***	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			04/28/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.05284	-118.44327	Plan check for T-24 only. Remodel the common area in The Colony. Total area: 3,327 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28824	17041-10000-33513	633 W 5TH ST 12TH FLOOR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	OFFICE TI. PC FOR POWER AND ENERGY. LOAD GREATER THAN 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28825	18041-10000-34052	6500 W WILSHIRE BLVD FLR 6, 7	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.06371	-118.3703	Full plan check for a office T.I located in a high rise building. Scope includes 6TH and  7TH FLOORS with new equipment and lighting that cover 24,000-SQ FT. Note. T-24 is under performance method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28826	16041-10000-39074	5630 N FAIR AVE	91601	2	174B173   803	2337031009	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Apartment			11/03/2016 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.17311	-118.37446	PC FOR POWER AND ENERGY. NEW IRREGULAR THREE STORY (TOTAL 15 UNITS) APARTMENT BUILDING OVER ONE LEVEL OF OPEN PARKING GARAGE. 1200A SERVICE, TOTAL AREA 21941 SQ FT. B# 16010-20000-02633 FIRE ALARM TO BE FILED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28827	19041-20001-08777	12142 W STAGG ST	91605	2	189B165   894	2307011015	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.21199	-118.39795	NEW 10.8KW AC ROOFTOP PV SYSTEM ON (E) SFD. SCOPE OF WORK INCLUDES (30) 360W SUNPOWER MODULES WITH INTEGRATED MICROINVERTERS,  AND (1) 125A PV DISTRIBUTION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28828	19041-10000-33014	5850 N CANOGA AVE # 100	91367	3	174B105     9	2149002016	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.17678	-118.59723	NEW DEMONSTRATION ROOM IN OFFICE SPACEPLAN CHK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28829	09041-10001-07719	457 S MARIPOSA AVE	90020	10	135B197   757	5502015014	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM			PC Info Complete	04/12/2010 12:00:00 AM	ADDRESS	34.06558	-118.29937	Tenant improvement - lighting remodel . Title 24 only. AND EMERGENCY LIGHTING.   This project is Plan check only.  Permit is existing under 09041-20000-07719	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28830	13041-20000-14507	7534 W WOODROW WILSON DR	90046	4	156B177   309	5570008007	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.12396	-118.36001	PV1 FOR ONE STORY SINGLE FAMILY DWELLING STANDARD PLAN. TOTAL SYSTEM SIZE 8.085KW. 33 MODULES AND 1 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28831	18041-10000-38109	19701 S HAMILTON AVE 1ST & 2ND-FLR.	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	33.85221	-118.28625	PLAN CHECK FOR POWER AND ENERGY FOR - INTERIOR TENANT IMPROVEMENT TO INCLUDE NEW NON-BEARING PARTITION WALLS, CEILING, MILLWORK AND FININSHES ON FIRST FLOOR (17,413 SF) AND SECOND FLOOR (6,564 SF) - TOTAL CONNECTED LOAD >400A ON EXISTING 4000A SERVICESEE COMMENTS FOR ADDITIONAL INFOMATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28832	18041-10000-19346	8578 W PICO BLVD	90035	5	129B173    82	4303035026	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.05348	-118.37795	T-24, PC FOR ENERGY ONLY. TI FOR A BAKERY STORE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 565 SQ. FT. B#17016-30000-22199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28833	16041-10000-00600	8810 N TAMPA AVE WHE. #437	91324	12	195B121   511	2784003069	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.23097	-118.55317	T.I. OF THE (E) RESTROOM . INSTALL NEW LIGHTING, PC FOR ENERGY ONLY, TOTAL AREA 766 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28834	14041-20001-02606	7944 N ANDASOL AVE	91325	12	189B133   404	2201022018	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.21542	-118.5116	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28835	14041-10000-04507	655 W JEFFERSON BLVD	90007	9	120A201    58	5123009017	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.02292	-118.28182	INSTALLATION OF A NEW FIREALARM PANEL AND 8 DEVICES. 2 STORY BUILDING ( ELECVATOR RECALL SYSTEM), ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28836	10041-20000-19984	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM			PC Approved	10/07/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	energy plan check # 980	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28837	14041-10000-17345	21926 W COSTANSO ST	91364	3	171B101   313	2169003042	C2-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.16743	-118.605	TI  and  remodel existing STORE, ADD NEW ACCESSIBLE RESTROOMS.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28838	17041-10000-10927	1320 E 7TH ST #126	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Closed	12/04/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	PC FOR ENERGY. CHANGE OF USE FROM RETAIL TO NEW SIT DOWN RESTAURANT. TOTAL AREA 765 SQ FT.  COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28839	15041-10000-23692	2470 S WESTERN AVE Unit #C	90732	15	009B193   126	7460004007	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2973.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	33.72319	-118.31224	Energy plan check for single story restaurant ( Rock n Juice) T.I. Scope includes new lighting, receptacles and equipment. Total area is 1179-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28840	12041-10000-15082	615 E 61ST ST	90001	9	105B205   522	6007006024	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			Reviewed by Supervisor	08/29/2012 12:00:00 AM	ADDRESS	33.98449	-118.26437	Plan check for new 12.54KW roof mounted photovoltaic system for an existing commercial building with multiple services. Photovoltaic system will be installed for each services under seperate application. (1 of 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28841	12041-20001-22178	6605 N FALLBROOK AVE	91307	12	180B097   311	2038040015	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			PC Approved	03/30/2013 12:00:00 AM	ADDRESS	34.18874	-118.62363	Delta  I modifications to previously approved set of plans for Sprouts.  TENANT IMPROVEMENT FOR A RETAIL GROCERY STORE IN AN EXISTING BUILDING. NEW DISTRIBUTION BOARDS, PANELS, AND CKTs. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28842	19041-10000-41271	1246 W COURT ST	90026	1	135A209   290	5160019016	CW	Central	Westlake	Echo Park	YES	2080.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	04/29/2021 12:00:00 AM	ADDRESS	34.06337	-118.25549	NEW FIRE ALARM SYSTEM FOR A LOW RISE 6 STORY 54 UNIT APARTMENT BUILDING. TOTAL FA DEVICES 166 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28843	18041-10000-47029	2320 S LOUELLA AVE	90291	11	111B149  1221	4242033013	R1V2	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.99722	-118.44877	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 16 MODULES, 16 MICROINVERTERS (ENPHASE IQ7-60-B-US). SYSTEM SIZE IS 4.96KWdc and 4 kwAC. SCOPE INCLUDES 100A LOAD CENTER WITH 240VA AC DISCONNECT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28844	10041-10000-19057	835 W SOLANO AVE	90012	1	141B213    25	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Historic Cultural	YES	1971.10	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.07927	-118.23558	TI IN AN EXISTING PUBLIC RESTROOM.  PLAN CHECK IS FOR TITLE 24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28845	19041-20000-05285	15503 W VENTURA BLVD #220	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.15504	-118.4723	Plan check for power and energy. Project site is an existing suite in a commercial building. Project scope is a change of use from office to medical office. Total lighting area = 1,446 sq. ft.Note: Building application has been generated under 18016-10001-07617. See application comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28846	13041-20000-33450	5339 N CRANER AVE	91601	2	171B173   132	2416003014	MR1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.16811	-118.36925	Existing manufacturing building.  Change to service, new panels, circuits.  No change to lighting.  Plan Check for Power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28847	16041-20000-00520	14559 W HESBY ST	91403	4	171A151   152	2263033012	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.16226	-118.45078	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28848	11041-10000-13402	1515 S REXFORD DR	90035	5	129B165   302	4306015003	R1-1	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.05194	-118.39439	New 8.64 KW Solar system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28849	12041-10000-20591	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			Ready to Issue	09/18/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVEMENT IN A RETAIL STORE AT THE NORTHRIDGE FASHION CENTER, SPACE 70APLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28850	13041-10001-30915	14651 W COHASSET ST	91405	6	186B149   324	2218007003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.20675	-118.45264	Expedited RSES plan check per applicant request. (((PV1, Install 3 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 12 modules: HANWHA # HSL60P6-PB-4-250TW.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28851	14041-20002-18517	23601 W LADRILLO ST	91367	3	171B093   314	2047006009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM			PC Approved	08/26/2014 12:00:00 AM	ADDRESS	34.1659	-118.641	$0 plan check FEE DUE TO SENATE BILL 1222 FROM 2012((change in inverters and load center location. no change in design. ))))PV1Install roof-mounted solar array on SFD. System size: 12kW.(2) SolarEdge SE6000A-US-ZB-U transformerless inverters(53) SolarEdge P300 power optimizers(53) Trina Solar #TSM-255PA05.18 pv modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28852	18041-10000-19825	19845 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.23209	-118.56586	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28853	17041-10001-02858	1149 S BOYLE AVE #203	90023	14	123A219   117	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	34.03001	-118.22065	Changes to an approved set of plans. Changes include reducing lighting for existing office space, replacing lighting fixtures, and revising floor plans.Note: Permit is paid under PCIS#17041-10000-02858	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28854	13041-10000-15043	1999 S AVENUE OF THE STARS FLOOR 27	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			Corrections Issued	06/10/2013 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI on 27th floor of a commercial highrise building.  Conversion of server room to office space and upgrading lighting on rest of floor to comply with energy efficiency standards.  18,500 sq ft, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28855	17041-10000-42993	1801 E 41ST PL UNIT B	90058	9	114A213   137	5116029059	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	34.00713	-118.24109	PC FOR POWER AND ENERGY FOR CHANGE OF USE FROM WAREHOUSE TO INDOOR NURSERY. TOTAL CONNECTED LOAD >400A. TOTAL AFFECTED AREA  APROX. 3000 SQ.FT. SCOPE INCLUDES NEW PANELS LIGHTS AND RECETPACLES.B#17016-10000-35368	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28856	17041-10000-18108	7740 N LEMONA AVE	91405	6	189B145   554	2209043024	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.21145	-118.4593	Title 24 plan check.  New lighting in existing warehouse space.  Subpanel to remain existing.  Total area = 17,824 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28857	15041-10000-14567	550 S HILL ST LOBBY	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.04753	-118.25268	TI TO AN EXISITNG COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK IN LOBBY FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28858	13041-10000-24417	21836 W DE LA LUZ AVE	91364	3	168B105   886	2171024050	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.1532	-118.60194	PV1. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE : 10KW CENTRAL INVERTER. 40 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28859	19041-10000-28130	4001 W 6TH ST	90020	4	135B193   869	5503017002	C2-1	Central	Wilshire	Greater Wilshire		2117.04	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.06364	-118.31057	NEW SPRINKLER MONITORING SYSTEM IN A RESTAURANT. SYSTEM INCLUDES A FIRE ALAREM PANEL, ANNUNCIATOR, COMMUNICATOR AND 8 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28860	13041-10000-27159	1207 S MALGREN AVE	90732	15	015B189   399	7560016012	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	33.73296	-118.31386	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200 MAIN; WORK DONE ON A non-STANDARD PLAN.2 TOTAL STRINGS WITH OPTIMIZERS; DC UNGROUNDED, COMBINER BOX WILL BE USED; SYSTEM SIZE IS 7.75KW DC WITH (31) MODULES: TRINA #TSM-250PA05.18(1)SOLAREDGE #SE6000A-US(31)SOLAREDGE# OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28861	15041-10000-25847	523 W 6TH ST #701;710;-712	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EM CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28862	14041-20000-28429	10460 W REVUELTA WAY	90077	5	141B153   268	4362021029	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.0796	-118.43862	Plan check for power only. New 2-story single family dwelling. ~15,100sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28863	17041-20000-09540	5831 N NATICK AVE	91411	4	174B149   158	2244010019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.17671	-118.45437	Plan check for a PV1 roof-mounted PV system. System size is 9.6 kWac and consists of (30) AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28864	15041-20000-41897	11944 W RIVERSIDE DR	91607	2	168B165   551	2355014033	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Approved	12/11/2015 12:00:00 AM	ADDRESS	34.15745	-118.39376	PLANCHECK FOR T24 ENERGY. INDOOR LIGHTING FOR PARKING GARAGE. 5000 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28865	14041-20000-21339	3253 S MALCOLM AVE	90034	5	120B161   210	4254014028	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.02798	-118.41748	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(21) REC SOLAR REC260PE(21) SOLAR EDGE POWER OPTIMIZERS P300(1) SOLAR EDGE SE5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28866	13041-10000-27007	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.0484	-118.26248	pc for power and energy. 1200A SERVICE. New 6-tier parking structure with offices on the 6th floor.  NOT methane. fire sprinkler throughout? B occupancy as seen on 13010-10000-02439	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28867	12041-10000-26535	4260 N EAGLE ROCK BLVD	90041	1	156A219   115	5474022011	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.12246	-118.22336	New 56 unit  4story with subterranean garage multi-family affordable housing. New service, panels, and ckt. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28868	19041-10000-38712	1000 W TEMPLE ST	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Issued	10/15/2019 12:00:00 AM	ADDRESS	34.06171	-118.25046	TEMPORARY POWER FOR A NEW SEVEN STORY MIXED USE BUILDING WITH TWO LEVELS OF SUBTERANEAN GARAGE. SERVICE SIZE IS 3000A 277/480, 3PH 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28869	18041-10000-48397	5721 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	33.93303	-118.38277	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28870	19041-20001-01481	19530 W TUBA ST	91324	12	204B117   254	2726009006	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.25621	-118.55865	4/18/2019changes to an approved set of plans.  changes noted delta 1 only.  changes to add load center and relocate loads.((((PV1.  Install 10 kW AC / 9.28 kW AC-CEC roof mounted grid tied PV system.  (29) modules with 10 kW rated string inverter.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28871	14041-20001-05722	15724 W COVELLO ST	91406	6	186B141   179	2206014023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.20742	-118.47589	Fee for expedite only.*****Roof mounted PV system 4KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28872	15041-10000-10183	5450 W PICO BLVD SUITE 202	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.04862	-118.35714	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1335.  SCOPE OF WORK TO BE PERFORMED IN SUITE 202	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28873	11041-10002-14243	800 S FIGUEROA ST #1040	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	34.04771	-118.26116	TI TO AN COMMERCIAL OFFICE BUILDING.  PERMIT IS ON SEPERATE APPLICATION. PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28874	13041-20000-10602	16534 W LAS CASAS PL	90272	11	129B121   419	4419013066	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Closed	07/31/2013 12:00:00 AM	ADDRESS	34.04995	-118.54192	single family solar 7.5 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28875	13041-20000-15377	314 N BARRINGTON AVE PV-1	90049	11	135B141   121	4429023025	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2013 12:00:00 AM			Reviewed by Supervisor	06/25/2013 12:00:00 AM	ADDRESS	34.06895	-118.47258	PV-1. Two 7.5kW Inverters. (((due to complete change in system, new plan check submittal has been filed, this application has been closed.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28876	15041-20000-03902	6925 W HOLLYWOOD BLVD	90028	13	147B181   112	5548004022	C4-2D-SN, R4-2D	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Approved	02/09/2015 12:00:00 AM	ADDRESS	34.10171	-118.34113	ADDITION OF PANELS, TRANSFORMERS, AND CIRCUITS ONTO EXISTING MSB. PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28877	19041-10000-16950	1016 S TOWNE AVE #106	90021	14	124-5A211 349	5132009***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.03362	-118.24986	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28878	16041-10001-05784	3909 S NORTON AVE	90008	10	117B185  1063	5033006051	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.01428	-118.33276	02/23/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE MADE UNDER DELTA 1. CHANGES INCLUDE RELOCATING INVERTER, AC DISCONNECT, AND 125a MAIN SERVICE PANEL.NOTE: PERMIT PAID UNDER PCIS#16041-10000-05784(((((PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING CENTRAL INVERTER SYSTEM USING SOLAR EDGE SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 18 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28879	18041-10000-33942	15739 W VENTURA BLVD	91436	5	168B141   552	2261009012	C4-1L, R1-1, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.15563	-118.47654	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28880	16041-20000-16888	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.30363	-118.45814	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement/addition of a mezzanine. Total lighting area = 3,930 sq. ft.Note: Building application has been created under 16014-20000-02211	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28881	19041-20000-47568	6040 N PASEO LA VISTA	91367	3	177B085   196	2032030015	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.18239	-118.66716	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 11.34 KW DC/10 KW AC. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS, A LOAD CENTER, AND A 10 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28882	19041-10000-23526	2200 E CESAR E CHAVEZ AVE	90033	14	129A223   224	5183003026	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM			PC Info Complete	08/20/2019 12:00:00 AM	ADDRESS	34.04768	-118.2102	T-24 PLAN CHECK FOR TI TO AN EXISTING STORE. ( CHANGE OF USE FROM RETAIL TO RESTAURANT). SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 2551 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28883	10041-10000-10013	3255 W WILSHIRE BLVD	90010	10	135B197  1185	5502026020	C2-2, C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00, 2123.03	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	08/25/2010 12:00:00 AM	ADDRESS	34.06195	-118.29324	Change of use from office to Banquet Hall. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28884	17041-10000-29734	1630 W 186TH ST	90248	15	060B193   248	6108002022	P-1VL, [Q]MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	12/11/2020 12:00:00 AM	ADDRESS	33.86187	-118.30705	PC for power and energy for new outdoor Hydrogen gas dispensing facility for Toyota(No public access). PC includes installation of vehicle fuel dispensing, fuel storage, air compressors and device control panel with control diagram on pg E6.1. Total area of 5723 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28885	16041-10001-31245	1210 W 68TH ST	90044	8	102B197   532	6014023013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2016 12:00:00 AM			PC Info Complete	11/02/2016 12:00:00 AM	ADDRESS	33.97772	-118.29625	CHANGES TO APPROVED SET OF PLAN. CHANGES TO POINT OF INTERCONNECTION, SERVICE PANEL RATINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28886	19041-10000-34959	1660 W ANAHEIM ST	90731	15	030B197    11	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	05/28/2020 12:00:00 AM		Permit Finaled	01/28/2021 12:00:00 AM	ADDRESS	33.77884	-118.29327	T-24 PLAN CHECK FOR A TI TO A CHANGE OF USE FROM LOCKER ROOM TO FITNESS ROOM. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 3622 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28887	14041-10001-12622	8234 N VANSCOY AVE	91605	2	192B161   196	2308005008	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.22082	-118.40616	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER. TRANSFORMERLESS INVERTERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28888	19041-10000-06287	950 W 190TH ST	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	33.85814	-118.29219	Energy plan check for office T.I located in a commercial building with multiple floor. Scope includes new lighting and equipment with a total area of 2,355-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28889	13041-10001-22580	8000 W SUNSET BLVD 3RD FLOOR	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.09783	-118.36466	CHANGES TO APPROVED SET OF PLAN # 13041-10000-22580. CHANGES ARE CLOUDED. CHANGE OF LUMINAIRES IN DESIGN AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28890	10041-10000-14679	3831 S HUGHES AVE #610	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM			PC Approved	08/05/2010 12:00:00 AM	ADDRESS	34.02242	-118.39823	TI IN A DENTAL OFFICE. PLAN CHECK FOR T24. ( COMPLETE PLAN CHECK MAY BE REQUIRED BASE ON THE FIELD INSPECTION. PERMITE IS ALREDY EXIST FOR NEW SUB PANEL, LIGHTING, SWITCHING AND RECEPTACLES. # 10041-40000-12869)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28891	18041-20001-09820	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Closed	02/12/2020 12:00:00 AM	ADDRESS	34.23911	-118.3725	10/12/2018changes to an approved set of plans.  changes to upsize system size to 662.05 KW AC CEC, 730.345 KW DC and interconnection point FIT, total 9 inverters(66kW).  changes noted delta 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28892	17041-20001-44889	11210 N LASAINE AVE	91344	12	210B129   163	2711009006	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.27426	-118.51208	02/27/2018 Plan check for a PV1 roof-mounted PV system. PV system power has increased to 11.4 kWac/13 kWdc. Module count has remained the same.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28893	18041-20001-45117	3144 N CORDA DR	90049	11	159B137   486	4490004049	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM			PC Approved	12/07/2018 12:00:00 AM	ADDRESS	34.1296	-118.48812	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 21.78 kWdc/19.6 kWac-CEC and consists of (66) modules, (66) micro-inverters, (2) load centers, and (2) back-up batteries.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28894	19041-20000-52987	3710 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	04/23/2020 12:00:00 AM		Permit Finaled	11/02/2020 12:00:00 AM	ADDRESS	34.02027	-118.28994	T-24, PC FOR ENERGY  ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE LOAD TO AN EXISTING SPACE. TOTAL SQ. FT. 867.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28895	11041-10000-15788	533 W VERNON AVE	90037	9	112-5A201  25	5019010034	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.00388	-118.2839	New 3 story church with parking lot.  Main church is single story but attached section, office section, is three story.  PLan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28896	15041-20000-00661	1338 E M ST	90744	15	033B213    69	7425018015	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	33.78926	-118.24656	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Grounded system.18  327W pv modules across three strings (6+6+6).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28897	19041-20000-37901	4634 N LIBBIT AVE	91436	5	168B137   663	2284016035	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.15419	-118.48898	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 14.25 KW DC/ 11.4 KW AC. SCOPE OF WORK CONSISTS OF (38) PV MODULES WITH OPTIMIZERS AND A 11.4 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28898	14041-10000-30074	10889 W WILSHIRE BLVD	90024	5	132B153   290	4363022019	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.05908	-118.44352	Title 24 plan check only.  Total area = 550 sq. ft.Installation of new lighting on an elevated bridge between two buildings.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28899	14041-10000-07430	860 S BROADWAY	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.04235	-118.2558	T24, FOR A RETAIL STORE  BUILDING. TOTAL AREA 978 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28900	15041-20000-05255	19011 W PARTHENIA ST	91324	12	195B121   326	2784003028	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM			Corrections Issued	02/23/2015 12:00:00 AM	ADDRESS	34.22837	-118.54734	PC FOR RE-ENERGIZING EXISTING SERVICE BOARD. REMOVE 208V SERVICE. RE-ENERGIZE 480V. DUE TO CONDITION OF EXISTING SERVICE EQUIPMENT, PER ENGINEERING, FUSE LET THRU HAS BEEN PROVIDED. INSTALLATION OF TRANSFORMER. RELOCATE EXISTING LOADS TO 480V SERVICE. LOAD CALC PROVIDED. E15VN00433	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28901	18041-10000-20397	1900 S AVENUE OF THE STARS 19TH FLR.	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Info Complete	06/04/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	Energy plan check for janitor closet and existing restroom T.I. Scope includes new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28902	10041-10000-19157	20929 W VENTURA BLVD	91367	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM			PC Approved	09/27/2010 12:00:00 AM	PIN	34.16716286	-118.58942399	REMODEL IN A SUBWAY SANDWICHESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28903	14041-20001-00176	3249 N CAHUENGA BLVD WEST	90068	4	159B181   733	2429010004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.12921	-118.34863	(((EXPEDITE FEES)))PV2 COMMERCIAL ROOFTOP SYSTEM. USING 3 INVERTERS. TOTAL OF 30KW AC. PV INTERCONNECTION IS 240V 3PHASE 4 WIRE. WITH DELTA CONNECTION 3 PHASE INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28904	16041-20000-34578	8029 N LINDLEY AVE	91335	12	189B125   265	2102013007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2016 12:00:00 AM			Reviewed by Supervisor	10/28/2016 12:00:00 AM	ADDRESS	34.21649	-118.52751	PV1.  Installation of new ground mounted PV system.  5kW rated central inverter with (18) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28905	15041-10004-00589	12655 W BLUFF CREEK DR	90094	11	102B161  1281	4211037037	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/29/2017 12:00:00 AM			PC Approved	10/20/2017 12:00:00 AM	ADDRESS	33.97565	-118.41332	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 8 ON PLANS. SCOPE INCLUDES ADDITION OF ELECTRIC DRYERS TO ALL THE DWELLING UNITS (125 IN TOTAL). CHANGING EXISITNG CIRCUITS FROM 120 TO 208. REVISION TO PANEL SCHEDULES AND LOAD CALCS ON ALL DISTRIBUION LEVELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28906	12041-10000-11596	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Tenant improvement, T-moblie store. Space 202. Plan check for energy and emergency lighting. Commercial 1419 conditioned sqft. Low-rise commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28907	14041-20000-04094	3121 S LA CIENEGA BLVD	90016	10	123B173  1581	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.02996	-118.37306	Additional of office space for retail, suite A.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28908	14041-20000-24799	7000 S HOOVER ST Unit #4	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #4.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28909	17041-10000-00360	300 W WORLD WAY #335, 336,-337  T3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	PIN	33.94094587	-118.40577128	PC for Power and Energy for food court project in Terminal 3 of LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28910	15041-10000-18751	700 S FLOWER ST STE. 2400	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	Energy plan check for the 24th floor office T.I located at a righ rise building; Scope includes new receptacle, lighting and a new panel. Total corered 19,900 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28911	14041-20001-13139	13656 N FENTON AVE	91342	7	228B153   381	2503009007	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.32035	-118.43392	Fee for expedite only.****Roof mounted PV system.  System size 14.5KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28912	19041-20000-15078	3312 W ATWATER AVE	90039	13	153B209   581	5436022012	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.11518	-118.25577	Plan check for battery back up system installed into existing PV system, Energy storage system: 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28913	15041-20000-42177	11100 W SANTA MONICA BLVD 9TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	09/24/2016 12:00:00 AM	ADDRESS	34.04726	-118.44465	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 9TH FLOOR (OFFICE SPACE). SCOPE INCLUDES A NEW 225A PANEL AND NEW LIGHTING. TOTAL AREA IS 12,310 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28914	20041-10000-05573	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Issued	02/06/2020 12:00:00 AM	ADDRESS	33.98076	-118.40716	(13) NEW DUCT DETECTORS	N	N	Express Permit	06/10/2024 12:00:00 AM
28915	15041-20000-19693	16425 W TULSA ST	91344	12	210B137   852	2680022017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.26844	-118.49001	Plan check for a PV1 roof-mounted PV system. System size is 4.3 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28916	19041-10000-43259	7946 N STATEN DR	91335	12	189B125  1013	2103021084	(Q)RD6-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.21514	-118.53765	NEW PV1 INSTALLATION WITH AN EXISTING SERVICE OF 225 AMPS. INSTALLATION INCLUDES 1 INVERTER (SE6000H-US), 24 MODULES (SN310M-10/15 BOB), AND 24 OPTIMIZERS (P320).SYSTEM SIZE: 7.44 KW DC; 6.0 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28917	17041-20000-25467	1135 N HIGHLAND AVE	90038	4	144B185   625	5532019019	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.09157	-118.33885	New fire alarm system with (98) signaling line and notification devices.COMPLY WITH DEPARTMENT ORDER effective date05/19/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28918	16041-10000-33559	700 W WORLD WAY Terminal 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	PIN	33.94153561	-118.3984113	PC for energy only to LAX airport terminal 7, break room only. Adding new lighting and power. New lighting and power is clouded as noted in plans. Total sqft = 440.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28919	15041-20000-15051	11415 N ILEX AVE	91340	7	213B153   192	2616018019	M1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Issued	05/28/2015 12:00:00 AM	ADDRESS	34.27705	-118.43569	Plan check for a PV2 roof-mounted PV system. Ssytem size is 30 kWac and consists of (3) inverters, (140) modules, (140) power optimizers, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28920	17041-10001-37739	1360 N SOTO ST	90033	14	133-5A227 198	5202011038	RD2-2	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2018 12:00:00 AM			PC Approved	04/11/2018 12:00:00 AM	ADDRESS	34.05862	-118.20016	PV1. Plan check only for new solar system on a residential roof-top. PV system is feeding back into grid through a performance meter. Total System size is 2.1KWdc / 1.96KWac. (7)MODULES-SOLARWORLD SW-300(7)MICROINVERS-ENPHASE S280-60-LL-2-USNOTE: Permit is paid under under PCIS#17041-90000-37739	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28921	17041-20002-23699	5021 N MONTEZUMA ST	90042	1	151-5A225  85	5469009039	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.11089	-118.20564	11/30/2017Supplemental for master permit 17041-20000-23699This permit is for removal of tesla powerwall(battery back up) from original scope of work covered under master permit .Tesla powerwall shall be pulled under seperate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28922	15041-20000-18159	20358 W ARMINTA ST	91306	3	189B113   868	2107013040	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.21305	-118.57737	Plan check for PV roof mounted system. System size: 9.0kW with 30 modules and 2 inverters(3.0kW and 6.0kW) Transformerless	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28923	15041-10000-37403	555 W 5TH ST 34TH FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.05016	-118.25369	FULL PC, TI TO THE 34TH, OFFICE, FLOOR IN A (E) HIGH RISE BUILDING. TOTAL LOAD IS >400AMP. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 25,172	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28924	13041-10000-03047	1925 S CENTURY PARK EAST SUITE 1140	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM			PC Approved	02/06/2013 12:00:00 AM	ADDRESS	34.06066	-118.41426	T24 ENERGY ONLY AND EMERGENCY FOR EXISTING OFFICE SPACE. TOTAL AREA OF 850 SQ FT. PART OF HIGH RISE. SUITE 1140.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28925	18041-10000-37017	2920 W LOS FELIZ BLVD	90039	13	157-5A207  95	5435004042	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.12595	-118.26343	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28926	16041-20001-05968	9723 W BEVERLYWOOD ST	90034	5	126B165   777	4309006001	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM	ADDRESS	34.03991	-118.39849	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 13.16kW with 47 modules and  47 microinverter Enphase.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28927	14041-20000-23920	12801 W DESMOND ST	91331	7	216B161   157	2527011028	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.2884	-118.41142	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 10kW.(2) Aurora PVI-5000-OUTD-S-US-A transformerless inverters(30) Sunpower 327W pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28928	17041-10000-11864	4551 S GLENCOE AVE	90292	11	105B153   615	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	33.9844	-118.43407	ALTERATION TO (E)  EXTERIOR OUTDOOR SEATING AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28929	17041-20001-43644	12701 W HORTENSE ST	91604	2	168B161   712	2362022016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.15501	-118.40964	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.8.4kW ungrounded system.(30) 360W pv modules.(30) EnPhase IQ6-Plus-72 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28930	15041-20000-05175	1050 W CHILDS WAY	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.02262	-118.29103	Demo existing run of MV cable, install new run to replace. Cable to be of same gauge and configuration. Total length of MV cable approximately 400ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28931	11041-10000-00694	11050 W PENDLETON ST	91352	6	198B173    49	2408001904	[T][Q]M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM			PC Info Complete	01/12/2011 12:00:00 AM	ADDRESS	34.2392	-118.37196	Ti in an existing office building. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28932	14041-10000-35462	2118 E 7TH PL	90021	14	124-5A217 344	5166003012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.0334	-118.22922	New fire alarm system for existing building core and shell rehab project.  Total system size = 26 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28933	16041-10000-09938	2114 W KENT ST	90026	13	139-5A207 381	5402038007	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Apartment			03/22/2016 12:00:00 AM			PC Info Complete	05/09/2016 12:00:00 AM	ADDRESS	34.07452	-118.26604	FULL PC TO A NEW FOUR STORY 8 UNIT APARTMENT BUILDING WITH A ROOF DECK OVER A BASEMENT PARKING GARAGE. NEW 800 AMP OVER HEAD SERVICE DIVIDED INTO A SINGLE PHASE AND 3 PHASE SECTION.  NOTE: VARIANCE HAS BEEN FILLED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28934	16041-20000-45279	6801 N COLDWATER CANYON AVE 1st flr	91605	2	183B161   842	2327025028	C1-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.19443	-118.41396	"ti to an existing medical two story office.  scope of work in first floor only.  plan check for power and energy.""OSHPD 3 PROJECT"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28935	16041-10000-31392	611 S BROADWAY	90014	14	129A211   151	5144003015	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.04644	-118.25245	PC FOR ENERGY ONLY. ADDITION OF THE LOAD< 400A. TENANT IMPROVEMENT TO (E) KITCHEN AT BASEMENT .491 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28936	19041-20000-21767	3036 N NICHOLS CANYON ROAD	90046	4	156B177   179	5570034015	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.12594	-118.36227	PLAN CHECK FOR NEW 27KWH BATTERY SYSTEM OF (2) 13.5 KWH POWERWALL BATTERIES AND A  NEW 200A PANEL. EXISTING PV SYSTEM ON SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28937	17041-10000-19455	16930 W MULHOLLAND DR	90049	11	159B133   242	4490010003	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/24/2022 12:00:00 AM		Issued	06/24/2022 12:00:00 AM	ADDRESS	34.12878	-118.50176	PC FOR POWER FOR NEW SFD W/BASEMENT AND ATT. GARAGENEW SERVICE RATED AT 800A 120/208VNote: Portion of electrical permit fees paid under Combination Building Permit Number 15010-20000-02195	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28938	13041-20000-35484	11308 W PENROSE ST	91352	6	192B173   238	2632006012	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/29/2013 12:00:00 AM	ADDRESS	34.22442	-118.37769	Change to lighting in an existing commercial building.  Load is less than 400 amps per Engineer.   PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28939	18041-10000-19819	4030 S WESTERN AVE	90062	8	114B193   331	5021008030	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Issued	05/30/2018 12:00:00 AM	ADDRESS	34.01061	-118.30872	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28940	10041-10000-23253	3900 W MIDDLEBURY ST	90004	13	141B197  1219	5539032039	(Q)R3-1XL	Central	Wilshire	East Hollywood	YES	1927.00	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.07966	-118.28962	New fire Alarm system. Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28941	16041-20000-19559	8252 N MORSE AVE	91605	2	192B161   110	2304002015	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	34.22134	-118.4162	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (18) modules, and (18) power optimizers. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28942	15041-20001-02760	6530 N SEPULVEDA BLVD	91411	6	180B145   491	2235002005	R1-1, R4-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			06/14/2017 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	34.18936	-118.46595	6.14.2017 - Plan check for modifications to approved set. Split MSA into MSA1 and MSA2. Update a couple of unit floor plans. Rearrange a couple of units. Expand Gym. Changes clouded delta C.=====NEW 68 UNIT APARTMENT. PARKING GARAGE. PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28943	14041-10000-00495	1458 S SAN PEDRO ST #L-54	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES TO REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS.780 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28944	14041-10000-12644	2251 N ROSCOMARE ROAD	90077	5	153B145   139	4377011020	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.11408	-118.46383	PV1, INSTALL  9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER AND WITH OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28945	16041-10000-12701	5244 N VINELAND AVE	91601	2	171B173   423	2416004011	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			Verifications in Progress	07/21/2016 12:00:00 AM	ADDRESS	34.16618	-118.37015	PC FOR POWER AND ENERGY. NEW BUILD 1 STORY WAREHOUSE WITH 2ND FLOOR  FOR STORAGE. 600 A SERVICE AND 3 NEW 200A PANELS. TOTAL AREA 6806 SQ FT( INDOOR) PLUS 2509 SQ FT(OUTDOOR)B# 15010-10000-03991	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28946	11041-20000-24183	15030 W VENTURA BLVD #9	91403	5	168B145  1143	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/10/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	01/24/2012 12:00:00 AM	ADDRESS	34.15272	-118.46063	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT TO DENTAL CLINIC IN SUITE #9	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28947	13041-10000-34019	4824 N TUJUNGA AVE 1-31	91601	2	168B173   368	2353023007	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			12/06/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.15833	-118.37877	NEW FIRE ALARM SYSTEM FOR 31 UNIT APARTMENT COMPLEX. FULLY SPRINKLERED. 2 PANELS, 95 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28948	13041-10000-10494	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			PC Info Complete	06/14/2013 12:00:00 AM	PIN	34.12750533	-118.21285206	TI OF EXISTING OFFICES. ENERGY ONLY. TOTAL AREA 4000 SQFT. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28949	14041-20000-28335	5447 N SATSUMA AVE	91601	2	174B173  1282	2416012004	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.16999	-118.36764	600 AMP SERVICE UPGRADE.  CORE AND SHELL.  EMPTY PANELS FOR FUTURE TENENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28950	19041-20001-22736	5431 N WILLIS AVE	91411	4	174B149  1170	2249026006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	34.16944	-118.45546	PV1. INSTALL 6 KW AC PV SYSTEM WITH (20) MODULES/OPTIMIZERS AND (1) INVERTER (SE6000H). PLAN CHECK ONLY. PLAN REVIEW PER INSPECTOR'S REQUEST. NOTE: PERMIT INSPECTION FEE PAID ONLINE UNDER 19041-90000-22736	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28951	15041-10000-07369	13689 W FOOTHILL BLVD	91342	7	222B157    46	2509015027	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.30872	-118.43163	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS AND NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2245.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28952	19041-20000-53105	5353 N NOBLE AVE	91411	4	172-5A147 105	2250004020	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.16823	-118.46196	PV1. INSTALL 9.24 KW DC ROOFMOUNTED PV SYSTEM WITH (28) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28953	18041-20000-16008	4653 W BEVERLY BLVD	90004	4	138B193   400	5522032023	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.07641	-118.31094	TI to (E) commercial restaurant space.  Plan check for energy.  Building permit under 18016-10000-08138.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28954	17041-20000-36747	10144 W HOLLOW GLEN CIR	90077	5	156B153   152	4382025***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Expired	09/05/2023 12:00:00 AM	ADDRESS	34.12253	-118.44232	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for solar pv system (roof-mounted array) with AC coupled battery backup system for SFD.PV system size: 13.2kW ungrounded [(2) 6.6kW]. (48) 325W pv modules. (2) 5kW Powerwall 2s.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28955	11041-20002-01080	13912 W SATICOY ST	91402	6	186B153    32	2214023020	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.2102	-118.43599	Changes from previously approved plans.  Changes include some modules that are canopy mounted, reduce PV modules, and change from two meter to one meter.  Note: Previously approved plans submitted for reference only.*****Changes from previously approved plans.  Changes include adding a 30KVA transformer for 480 volt P.V. system and 125A circuit breaker for 120 Volt P.V. system.*****PERMIT WAS PREVIOUSLY ISSUED UNDER: 11041-20000-01080*****PLAN CHECK FOR ROOF MOUNTED 15.8KW AND 29.9KW PHOTOVOLTAIC SYSTEM FOR 2 EXISTING SERVICES SUPPLYING ONE BUILDING.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28956	19041-10000-36325	3200 W JEFFERSON BLVD	90018	10	120B185   855	5044007008	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM			PC Info Complete	09/12/2019 12:00:00 AM	ADDRESS	34.02547	-118.33065	ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT COMBINING THREE RETAIL STORES  INTO ONE. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 1727-SQ FT.BLD #: 19016-10K-19152	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28957	11041-10000-20676	1046-1054 E ELKGROVE AVE BLDG 18	90291	11	111B145   391	4243001036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.002	-118.45901	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28958	15041-20001-02033	13126 W BASSETT ST	91605	2	183B161   756	2327007146	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM			PC Approved	02/03/2015 12:00:00 AM	ADDRESS	34.1957	-118.41907	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.0KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28959	19041-20000-30746	6320 N CANOGA AVE 14th fl	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.18499	-118.59722	T24 PLAN CHECK ONLY FOR 14TH FLOOR CORRIDOR, CHANGE OF LIGHTS FROM FLOURESCENT TO LED. TOTAL SQUARE FOOTAGE = 1097 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28960	17041-10000-37585	15050 W ALTATA DR	90272	11	123B129   573	4411024012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.03267	-118.52326	PC for new house addition. Installing new 800A 120/240V service, new service equipment, four panels, circuits, lights, receptacles and equipment. Reconnecting existing panels to new service equipment. This is plan check only under combo permit 16014-30000-00663.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28961	17041-20000-11723	21820 W BURBANK BLVD STE 175	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.17228	-118.6032	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE #175.  7685 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28962	10041-10000-18829	2050 W JOHN S GIBSON BLVD CRANE #2	90731	15	024B201     7	7440016912	[Q]M3-1	Harbor	Port of Los Angeles	Northwest San Pedro, Wilmington	YES	2951.01	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Closed	11/05/2012 12:00:00 AM	ADDRESS	33.75959	-118.28627	INSTALL A NEW CRANE AT BIRTH #102 IN TERMINAL WBCT.  (CRANE #2 of 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28963	15041-10000-28435	12153 W MONTAGUE ST	91331	7	204B165    66	2537002011	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.25759	-118.39787	T24 ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE THEM WITH NEW LED LIGHT FIXTURES. TOTAL AREA 15860 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28964	15041-20000-15792	12674 W LULL ST	91605	2	186B161   316	2305024001	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.20855	-118.40974	Installation of new roof mounted solar PV array.  Total system size =  4.3 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28965	16041-10000-28542	10400 N SEPULVEDA BLVD	91345	7	204B145   113	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	05/04/2017 12:00:00 AM		Issued	05/04/2017 12:00:00 AM	ADDRESS	34.25939	-118.46706	Electrical work for construction of new 24 hour fitness TI full plan check for power and energy.((B# 16016-10000-18853))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28966	19041-10002-27893	19546 W ELKWOOD ST	91335	3	189B117   765	2105009012	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	34.21265	-118.55971	CHANGE OF AN APPROVED SET OF PV1. CHANGE INCLUDE CHANGING THE LAYOUT OF THE SOLAR MODULES LOCATIONS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28967	13041-10000-10813	801 E 7TH ST	90021	14	126A213   287	5147028039	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/26/2013 12:00:00 AM			PC Approved	04/26/2013 12:00:00 AM	ADDRESS	34.03955	-118.24481	TI OF EXISTING RETAIL SPACE. CHANGING LIGHTING FIXTURES; PLAN CHECK FOR TITLE 24 ,ENERGY ONLY. TOTAL AREA OF 3,977. PROJECT COVERS UNITS 1,2,3. PERMIT TO BE ISSUED BY PLAN CHECK STAFF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28968	19041-10000-53459	8515 N TELFAIR AVE	91352	6	192B169   350	2632023065	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	34.22411	-118.38403	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28969	18041-20000-33591	309 E 8TH ST	90014	14	126A211    30	5145003009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.04121	-118.25128	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total outdoor lighting area = 300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28970	14041-10001-33097	8876 W VENICE BLVD	90034	10	123B169  1385	4312015005	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.02984	-118.38677	CHANGES TO AN APPROVED SET, NOTE CHANGES ON DELTA 4. CHANGES INCLUDE THE ADDITION OF A NEW TENANT TO AN (E) SWITCH GEAR. 6 NEW PANELS AND 2 NEW TRANSFORMER. (((Full plan check for a commercial/ industrial building T.I and service upgrade to 2500-Amp with existing load reconnected to the new service.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28971	14041-20000-34783	5550 N TOPANGA CANYON BLVD SUITE 310	91367	3	174B101   285	2146007119	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.17162	-118.60554	TI TO AN EXISTING LOW RISE COMMERICAL OFFICE BUILDING. LIGHTNING CONTROL REPLACEMENTS. REPLACING LIGHTING CONTROLS IN 6 OFFICES. OFFICE 306, 307, AND 315-318. NO CIRCUITS TO BE ADDED. PLAN CHECK FOR TITLE 24 ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28972	19041-10000-51287	839 N HIGHLAND AVE	90038	5	141B185    91	5524003019	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Issued	12/12/2019 12:00:00 AM	ADDRESS	34.08633	-118.33878	Replacing Existing outdoor HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28973	18041-20000-13486	7801 N MARQUAND AVE	91304	12	189B089   337	2020027046	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	04/28/2018 12:00:00 AM	ADDRESS	34.21218	-118.64939	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28974	16041-20001-06276	1360 W 71ST ST	90044	8	102B197  1062	6014033001	R3-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	33.97524	-118.30007	04/18/2016 Supplemental plan check for a PV1 roof-mounted PV system. Plan check per inspector request.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28975	14041-20000-25458	21301 W BURBANK BLVD 5TH FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.17351	-118.59524	TI FOR FULL 5TH FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28976	18041-20000-04296	8200 N VAN NUYS BLVD	91402	6	192B149   510	2212004037	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Issued	12/20/2018 12:00:00 AM	ADDRESS	34.21993	-118.44858	PV2.  Install roof mounted feed-in tariff PV system sized 332.64 kW DC / 286.87 kW AC-CEC.  (1008) modules with (4) 36 kW and (6) 28 kW rated string inverters.$0 permit fee due to State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28977	12041-10002-26642	7080 W HOLLYWOOD BLVD	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM			PC Approved	12/13/2012 12:00:00 AM	ADDRESS	34.10134	-118.34445	Addition of emergency lights. Plan Check Only.******************************************RENOVATION OF (E) NIGHTCLUB, NO CHANGE OF USE.  Electrical plan check for assymbly area with more than 100 occupants.  T-24 and emergency lighting and power for the building.  Only change is to the lighting system.  The power system has no change. note : plan chk fee paid 11-15-12 on LA 03 17 350837  amt $266.66	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28978	12041-10000-17868	4790 N GLENALBYN DR	90065	14	148-5A223  32	5466031005	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.10305	-118.21094	New 3.9kw Transformerless PV System for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28979	14041-20000-30499	11819 W KAGEL CANYON ST	91342	7	210B169   121	2530006004	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1041.08	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			Reviewed by Supervisor	11/26/2014 12:00:00 AM	ADDRESS	34.27339	-118.39058	Plancheck for Ground mounted PV system with point of connection to DWP vault. Feed in Tariff.    Total system size: 816 KW. ( 312 KW Lakeview and 504KW Brookview)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28980	17041-10000-07961	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Apartment			03/13/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Issued	05/17/2017 12:00:00 AM	ADDRESS	34.04403	-118.2199	PC T24 TI energy only for a home of the aging with special care. Total area is 1659 sqft. This is classified as an R2.1 occupancy with no nursing.  Buiding permit 16016-10000-23722.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28981	13041-10000-33099	23229 W CALIFA ST	91367	3	177B093   855	2041006005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.17725	-118.63332	PV1, Install 6.25 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter(s):Solaredge SE6000A-US. 25 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28982	19041-10000-17162	11150 W SANTA MONICA BLVD #850	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	Energy plan check for an office T.I located on the 8th floor of a high rise building. Scope includes new lighting and equipment with a total area of 3579-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28983	19041-20000-05582	1866 E 1ST ST	90033	14	129A221   260	5174018036	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM			PC Info Complete	09/06/2019 12:00:00 AM	ADDRESS	34.04645	-118.21774	Plan check for power and energy. Project site is an existing 3-story mixed use building. Building consists of (1) floor of commercial and (2) floors of residential. Project scope is an adaptive re-use. Work includes an 800 amp service and a total lighting area of 5,581 sq. ft.Note: Building permit has been issued under 15014-10000-01229	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28984	11041-10000-14362	633 W 5TH ST 36TH FL	90071	9	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN EXISTING OFFICEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28985	14041-20000-19325	18233 W SUNBURST ST	91325	12	195B125    36	2769008032	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.23465	-118.53058	Standard Plan: 4.3KW PV1 roof-mounted system with one SolarEdge SE3800A transformerless inverter, (17) Trina Solar TSM-255 watts modules and SolarEdge Power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28986	11041-20000-14795	127 S SAN VICENTE BLVD Bulletin-87TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION Delta # 87 TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28987	15041-10000-28951	6255 W SUNSET BLVD ste 1060	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	PC for power energy, t-24 for a commercial bldg. (offices). Scope of work: new lighting fixtures and power reeptacles. Sq Ft = 2653	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28988	17041-10000-32174	13011 W VICTORY BLVD	91606	2	180B161   790	2326017013	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.18799	-118.41651	PC FOR RESTAURANT TI  (CHANGE OF USE(E) RETAIL -TO- (N) TAKE-OUT RESTAURANT) IN 1-STORY COMMERCIAL BLDG FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, EQUIPMENT, LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA 705 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28989	17041-10001-12711	1060 S BROADWAY	90015	14	126A209   131	5139014011	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			PC Approved	06/05/2019 12:00:00 AM	ADDRESS	34.0397	-118.25861	Plan check only. DELTA 1 CHANGES TO AN APPROVED SET. CHANGES TO WIRE TYPE ONLY AS SHOWN ON THE FIRE ALARM FIRE LEGEND. Original Plan check:((Plan check for a fire alarm system for a 10-story hotel. Fire alarm consists of (1) FACP, (1) annunciator, and (520) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28990	15041-20000-43500	3416 N FLOYD TER	90068	4	159B181   124	5579005025	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM			Reviewed by Supervisor	01/15/2016 12:00:00 AM	ADDRESS	34.13404	-118.34365	Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (1) inverter and (60) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
28991	17041-20000-12515	8850 N CORBIN AVE	91324	12	195B117    62	2783025091	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.23146	-118.56211	ti to an existing commercial building single story.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 2349.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28992	18041-10003-16557	4121 W SANTA MONICA BLVD	90029	13	145-5A201 370	5429002035	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	02/21/2020 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.09205	-118.28241	"DELTA ""2"" CHANGES TO APPROVED PLANS. INSTALLING A NEW 1,600 AMP SERVICE (PS2) AND A MAIN 1600 AMP OUTDOOR BREAKER AND CHANGING THE METHOD OF POWER FEED FROM DWP's TRANSFORMER TO 1,600AMP  (PS2) AND UPDATING THE FAULT CURRENT CALCS AND SHORT CIRCUIT RATINGS."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
28993	16041-10001-17669	19328 W NASHVILLE ST	91326	12	210B117   280	2718023015	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	34.26912	-118.55482	FEE EXPDITED PER APPLICANT REQUEST.PV 2 SYSTEM  RATED 12.7 KW(AC)  INCLUDING 40 PANELS    SUNPOWER SPR327NE-WHT-D 2 INVERTERS SMA SB7700TL-US-22   SMA SB5000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28994	14041-10000-17370	3245 S LA CIENEGA BLVD	90016	10	123B173  1679	4205035002	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.02879	-118.37386	Plan check for power and lighting.  Total area = 15,351 sq. ft. conditioned; 9,860 sq. ft. outdoor.Core and shell.  Installatino of new pannels, transformers, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
28995	10041-10000-16493	6020 N CANOGA AVE #100	91367	3	177B105   119	2149005051	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM			Corrections Issued	08/23/2010 12:00:00 AM	ADDRESS	34.1801	-118.59721	TI IN AN EXISTING RESTAURANT IN UNIT # 100 (ASAKA SUSHI). PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28996	15041-10000-08755	5275 W WASHINGTON BLVD	90019	10	126B177   881	5064004025	[T][Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	PIN	34.04112222	-118.35695617	TI-24  REMOVE HID FIXTURES AND REPLACE WITH LED FIXTURES. ENERGY SQ. FT. 5720	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28997	14041-10000-21396	14402 W CALIFA ST #5	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
28998	14041-20000-04891	14006 W RIVERSIDE DR #270	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM			PC Approved	01/20/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I. to existing building Space #270. Install general/emergency lighting. Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
28999	14041-20000-02600	22853 W ENADIA WAY	91307	12	183B097   149	2026002028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.2002	-118.62518	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29000	15041-10000-39563	12411 W FIELDING CIR	90094	11	105B161  1220	4211034062	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	33.97968	-118.40871	"PROPOSED 3'-6"" X 20' S/F  LEDs ILLUM. MONUMENT SIGN ""A"" (""VILLAS AT PLAYA VISTA, APARTMENT HOMES"")PLAN CHKIS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29001	10041-10000-12157	3785 W WILSHIRE BLVD APT 2306	90010	10	135B193  1023	5503030903	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			06/25/2010 12:00:00 AM	07/19/2010 12:00:00 AM		Permit Finaled	12/09/2010 12:00:00 AM	ADDRESS	34.06187	-118.30858	NEW RESIDENTIAL APARTMENT.  SUITE # 2306. CORE & SHELL APPROVED UNDER A DIFFERENT PCIS#.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29002	16041-10001-20470	1025 E ADAMS BLVD	90011	9	118-5A209 348	5131026029	C2-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	34.01916	-118.25542	Change to approved set by modifying 2-type fixtures (A/A1 and T) on the floor plan . All changes are under clouded area only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29003	11041-20000-06709	12215 W VICTORY BLVD	91606	2	180B165   716	2322006024	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1238.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.18684	-118.39918	CHG OF USE / T. I. FROM STORAGE(previously JC PEnny call center before the storage) TO TRADE TECHNICAL SCHOOL & STORAGE.  PLAN CHECK FOR POWER AND ENERGY.  No new load is added .  Panels on PUDA and PUDB used existing circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29004	19041-20000-49145	22342 W WYANDOTTE ST	91303	3	186B101   894	2023028031	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.20265	-118.61374	NEW ROOF MOUNTED 9.71KW PV SYSTEM WITH 29 @ 335W AND ENPHASE MICRO INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29005	16041-20000-33390	2148 E BAY ST	90021	14	123A217   191	5166005010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.0314	-118.22816	Plan check for power and energy. T.I. to (e) warehouse/manufacturing building/lab. New lighting and power. 4160V system/equipment in lab. 1,308sqft. Service feeding this equipment was upgraded, under application number #16041-20000-33395.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29006	17041-20001-01689	6656 N LANGDON AVE	91406	6	180B145   192	2234018029	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.19188	-118.469	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29007	19041-10000-44912	6233 N VARIEL AVE	91367	3	177B105    18	2149001027	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM			Reviewed by Supervisor	11/15/2019 12:00:00 AM	ADDRESS	34.18397	-118.59309	Power plan check for a temp' power work site. Scope includes (1) 1000-Amp service, (3) transformers and other associated equipment.Per building application: 5 story mixed used	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29008	13041-10000-34618	2044 S COTNER AVE	90025	5	126B153   644	4323024014	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.04111	-118.44073	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 1500 SQ FT. REPLACING TOTAL OF 8 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29009	14041-20000-01075	17840 W VENTURA BLVD	91316	5	171B129   478	2182002014	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.16305	-118.52135	T24 FOR EXISTING RALPHS. TOTAL NEW LOAD DOES NOT EXCEED 400Anote to plan checker: submittal-2 fee needs to be paid to account for difference in square footage ( $238.68 )permit fee already calculated under inspection period (Delete this comment after)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29010	10041-20002-15411	14731 W RAYEN ST	91402	6	195B149   247	2651012028	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Apartment			09/21/2011 12:00:00 AM			PC Approved	09/21/2011 12:00:00 AM	ADDRESS	34.23197	-118.45487	Plan check for revision Delta 5 to approved plans. Revision consists of service load calculation, residential unit loads, residential panel size ratings, residential feeder sizes, residential overcurrent protection sizes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29011	18041-20000-38946	962 N SOMERA ROAD	90077	5	144B149   333	4369034012	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	11/07/2020 12:00:00 AM	ADDRESS	34.08764	-118.45671	Plan check for PV roof mounted system, syste size: 13.86KW DC, 11.4KW AC with 24 PV modules and 1 inverter(11.4KW) connected to existing 600A  Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29012	12041-10000-27943	1901 1/2 S BUNDY DR 1/2	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.03435	-118.45789	CUSTOMER BROUGHT CHECK. PLEASE RECALCULATE FEES BEFORE FINAL APPROVAL. NEW SERVICE? separate fire alarm variance filed 6/17/2013 mtNEW PARKING GARAGE. FULL POWER AND ENERGY PLAN CHECK. new parking facility. 833 car. 5 and half tier.  68621 sf below and 187934 sf above grade. 981 sf of attached restrooms and lockers. total SF = 257536 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29013	18041-10000-25475	2700 S FIGUEROA ST	90007	9	121-5A203  98	5123018033	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.02708	-118.27647	Full PC for a First time tenant to space, New Restaurant. Scope of work includes new panel, new lighting and receptacles. Total sq. ft. 4063.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29014	10041-20000-08381	19871 W NORDHOFF ST #2A	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM			PC Info Complete	05/05/2010 12:00:00 AM	ADDRESS	34.23203	-118.56649	Plan check T-24 energy (general/emergency) lighting for existing office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29015	13041-10000-25042	3150 W SAN FERNANDO ROAD	90065	13	153B209   408	5458002013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.11582	-118.24713	PLAN CHECK POWER AND ENERGY FOR NEW CAFE AREA FOR EXISTING BUILDING. EXISTING 1600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29016	17041-10000-04836	6329 S DENVER AVE	90044	8	105B201  1234	6004020014	R2-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Issued	02/14/2017 12:00:00 AM	ADDRESS	33.98157	-118.2839	NEW ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE 4.5KW USING M250 MICRO INVERTERS, AND 18 MODULES(SOLARWORLD SW290 MONO)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29017	13041-10001-23946	8831 W VENICE BLVD	90034	10	123B169  1196	4312008041	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.03083	-118.38619	[[[6/10/14]]]] CHANGES TO APPROVED SET. PLANCHECK FOR T24 ENERGY. 4871 SQFT, EMERGENCY LIGHTING.Tenant improvement of (E) 2-story rehabilitation center office.  Title 24 plan check only for lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29018	19041-20000-52305	10526 N SAMOA AVE	91042	7	207B201   328	2566003045	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	PIN	34.26026439	-118.28662572	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 8..03 KW DC/6.38 KW AC. SCOPE OF WORK CONSISTS OF (22) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29019	12041-10001-03089	25820 S NORMANDIE AVE	90710	15	033B197   107	7411020039	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	33.7888	-118.29726	Plan check for 2 temp 800A services, equipment, and panels to supply temporary trailer yard at Kaiser for construction. Site on Methane Zone all the construction is above the M. zone. Branch circuits and equipment in trailers are prefabricated. Variance was submitted for 30 Days demand reading on each 800 Amp service. Mike Packard will verify the exact conditions in the field and also the results of the demand readings. permit was issued under 12041-10000-03089	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29020	14041-10000-17636	11926 W ALLEGHENY ST	91352	6	198B169   140	2631003030	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.23707	-118.39293	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 14420 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29021	19041-10000-41333	6919 N HAYVENHURST AVE	91406	6	183B137   341	2225002096	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.19629	-118.49258	NEW CIRCUITS FOR  ELECTRIC VEHICLE CHARGERS.	Y	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29022	16041-20000-12840	145 S SERRANO AVE	90004	10	138B193  1153	5517009012	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.07235	-118.30686	PV1.  Install 5.70 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.  (20) modules with 6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29023	16041-30000-04618	8938 N CHIMINEAS AVE	91325	12	195B125   301	2769015023	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.23286	-118.52835	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 7.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29024	10041-20000-02479	6760 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	04/08/2010 12:00:00 AM	ADDRESS	34.11852	-118.34082	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29025	10041-10001-11280	21300 W ERWIN ST	91367	3	177B105    36	2149005042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM			PC Approved	09/08/2010 12:00:00 AM	ADDRESS	34.18266	-118.59548	Construction changes to permitted set of plans- changes are identified on the plans by  bubbles and  delta 5 markings nearby	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29026	16041-10002-14565	1616 W 209TH ST	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	01/10/2017 Changes to an approved set of plans. Changes include from 100A main breaker to 60A main breaker. Changes has been clouded. {{{{{CHECKING FOR CHANGE IN POI. UPGRADING MAIN SERVICE TO 400 WITH MULTI METER BANK. PLAN SHOWS PV INTERCONNECT TO UNIT SUBPANEL.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29027	16041-10000-15945	8500 N BALBOA BLVD #100	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTING COMMERCIAL BUILDING (SHOW ROOM). SCOPE INCLUDES 9 NEW SUBPANELS, 1 NEW 600A DISTRIBUTION BOARD, TWO NEW TRANSFORMERS, AND NEW LOAD EQUIPMENT.  NEW CONNECTED LOAD IS > 400A. TOTAL AFFECTED AREA IS 18078 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29028	16041-10000-30664	3201 S HOOVER ST 8C1	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	34.02548	-118.28442	Title 24 plan check only.  Total area = 1,236 sq. ft.    New lighting and receptacles in existing office suite.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29029	15041-10001-03561	730 W 109TH PL	90044	8	088-5A199 169	6075004009	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	ADDRESS	33.93635	-118.28817	Expedite per applicant request((((Plan check for PV roof mounted with 5.23kW with 21 modules and 1 inverter)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29030	12041-10000-11436	4254 N PERLITA AVE	90039	13	159B205   450	5594010013	(T)(Q)RD2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.13075	-118.26814	Plan check for new roof mounted Enphase M215 Microinverter photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29031	13041-10000-09658	11845 W CHAPARAL ST	90049	11	135B141   538	4402006006	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM			PC Approved	05/01/2013 12:00:00 AM	ADDRESS	34.06484	-118.47369	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A TWO STORY FAMILY DWELLING. SYSTEM SIZE IS 9.39 KW. [MODULES: PHONOS SOLAR # PS260M-20/U INVERTER: SMA # SB10000TL]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29032	13041-10000-33544	1015 S WALL ST	90015	14	126A211   424	5145019027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.03739	-118.25362	Remove HID light fixtures and replace with new fluorescent fixtures in retail unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29033	18041-20000-07678	7640 N AIRPORT BUSINESS PKWY	91406	6	186B137   544	2205009084	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Closed	02/07/2024 12:00:00 AM	PIN	34.20926268	-118.49463253	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the replacement of existing fixtures with LED fixtures. Total lighting area = 49,900 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29034	17041-10000-07750	19603 S VERMONT AVE	90502	15	057B197    32	7351034024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	33.85256	-118.29073	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 70925 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29035	16041-10001-17522	1840 S CENTURY PARK EAST 2nd Flr	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	Changes to approved set. 2nd floor in a high rise.  scope of work includes reduction of luminaire throughout the floor plan, new fixtures were added to the fixture schedule. Changes under delta 6. ***********************************************************************************TI: TENANT IMPROVEMENT ON (E) OFFICE  2ND FLOOR.  NEW CONNECTED LOAD LESS THAN 400A. PC FOR T-24 ONLY. TOTAL AREA: 14,764 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29036	12041-20000-17556	8960 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM			PC Approved	07/26/2012 12:00:00 AM	ADDRESS	34.23323	-118.55337	T.I. for Big Lots retail store.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29037	16041-10003-13870	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA  9 AND 10. SOME FLOOR PLAN REVISION. UPDATED PANEL SCHEDULE AND T24. pc only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29038	16041-20001-39553	20524 W LANTANA CT	91326	12	216B109   235	2701082049	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.2914	-118.58067	RSES expedited plan check fee per applicant request.  PV1.  Install 10.89 kW AC PV system, grid-tied.  (44) modules with Enphase M250 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29039	15041-10000-01655	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM			PC Approved	01/20/2015 12:00:00 AM	ADDRESS	34.05494	-118.23752	"PC FOR TITLE 24 ENERGY ONLY.{install (n) 28'3.5"" x 13'8"" coffee shop kiosk on the ground floor concourse of union station with non-bearing partitions and suspended ceilings.} TOTAL AREA 373 SQ FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29040	14041-20000-11870	14622 W VENTURA BLVD	91403	4	166-5A151 118	2276002066	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM			Corrections Issued	05/05/2014 12:00:00 AM	ADDRESS	34.15125	-118.45177	TI FOR EXISTING GYM. PLAN CHECK IS FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29041	14041-10000-10509	1930 S LA CIENEGA BLVD 1-23	90034	10	126B173   605	5066004020	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM			Corrections Issued	04/22/2014 12:00:00 AM	ADDRESS	34.04164	-118.37641	T.I. of existing office1300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29042	18041-10000-38740	6600 N TOPANGA CANYON BLVD SPACE #62	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Energy plan check for a retail TI. Scope includes new lighting and equipment with a total area of 816-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29043	19041-20000-16131	20752 W BEECH CIR #314-pv1	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.29397	-118.58543	pv1install roof mouinted pv systen sized 3.02KW AC interconnected with msp.(9) acm with 335 W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29044	18041-10000-32279	9224 N RESEDA BLVD	91324	12	198B125   230	2764012004	QC4-1VL, QP-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.23796	-118.53589	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29045	18041-10001-08941	11541 W COOLIDGE PL	90066	11	117B153   175	4250017026	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Expired	09/15/2023 12:00:00 AM	ADDRESS	34.0198	-118.43296	FEES FOR TESLA BATTERIES. PV 1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND TESLA BATTERIES. (46) MODULES, (2)  6.6, 3.8 INVERTERS, AND NEW LOAD CENTERS. TOTAL PV SYSTEM SIZE IS 11.895 KWDC/10.4KWAC AND BATTERY SYSTEM SIZE IS 11.6KW/ 27KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29046	18041-20001-34889	12936 W ADDISON ST	91423	4	168B161  1197	2358023023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.16107	-118.41511	SUPPLEMENTAL PLAN CHECK ONLY CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. CHANGE TO SINGLE LINE, CHANGE TO PV MODULE MODEL, FEEDER SIZES, OCPD SIZES, OPTIMIZER MODEL, INVERTER MODEL, AND THE COVER PAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29047	14041-10000-02064	1640 S SEPULVEDA BLVD 310	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.04838	-118.44468	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT WORK ON 1,681 SQ.FT. OF THE TOTAL FLOOR AREA, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29048	18041-20000-06686	9007 N LANKERSHIM BLVD	91352	6	195B169   120	2631028003	C2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Issued	02/23/2018 12:00:00 AM	ADDRESS	34.23322	-118.38803	replace existing fixtures with new led fixtures.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29049	18041-10001-39532	950 W 190TH ST	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	33.85814	-118.29219	"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 6. CHANGES INCLUDE REMOVING FUSED DISCONNECT AND VFD FOR ""SF-1"" & ""SF-2, AND REVISING LOAD SUMMARY. NOTE: PERMIT IS PAID UNDER MASTER APPLICATION PCIS#18041-10000-39532"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29050	13041-20000-21990	1673 W 251ST ST	90710	15	036B193   142	7410019013	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	33.79689	-118.30671	PV1 TRANSFORMERLESS SYSTEM WITH DC COMBINER. TOTAL SYSTEM SIZE 8KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29051	15041-20002-11736	6256 N TOPANGA CANYON BLVD C-1200	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	08/20/2015 Changes to an approved set of plans. Changes include the replacement of light fixtures above the service area from track to downlights. Exterior emergency lights have also been removed. Changes have been clouded and marked as Delta 3.08/10/2015 Changes to an approved set of plans to reflect field changes. Changes include the addition of lighting to a mezzanine. All lighting changes have been reflected onto the Title 24 Compliance Forms. All changes have been clouded and marked as Delta 2.*****Previous Work Description*****TI to new commercial building (restaurant). Plan check for power and energy.  Total Sqft. 2235.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29052	16041-20000-12278	6801 W HOLLYWOOD BLVD B2-239	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	Plan check for Title 24 only. Project site is a suite within an existing building. Project scope is a tenant improvement. Total lighting area = 1,207 sq. ft.Note: Building permit has been pulled under 16016-10000-01936	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29053	11041-20000-12102	6100 W WILSHIRE BLVD 520	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM			PC Approved	06/13/2011 12:00:00 AM	ADDRESS	34.06282	-118.36187	Plan check T24 Energy general/emergency lighting for Tenant improvement #520. Existing permit#11041-90000-10684	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29054	18041-10000-38663	6421 N GLORIA AVE	91406	6	180B141   881	2233014003	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM			PC Info Complete	10/10/2018 12:00:00 AM	ADDRESS	34.18728	-118.47945	NEW ROOF MOUNTED 9.8KW PV SYSTEM WITH 28 PV PANELS ON A SINGLE FAMILY HOME.PLAN CHECK ONLY. PERMIT: 18041-10000-18831 & 18041-10000-18819	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29055	15041-10000-03516	16644 W CALLE HALEIGH	90272	11	138B121   219	4431041029	(Q)RD3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.07364	-118.54888	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (27) modules, (1) inverter and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29056	11041-10000-25228	945 W 190TH ST	90248	15	060B197   559	7351029019	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.85849	-118.29245	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TI DOG KENNEL. PERMIT FOR NEW CKTS AND PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29057	19041-20000-25241	295 W DOCKSIDE LANE 295-273	90731	15	015B201   304	7455023027	RD1.5-1LD	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	33.73652	-118.28339	MULTIPLE SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE. NEW 800 AMP, 120/240 1PH. LOT 12-24.Building BB# 17010-20000-03213	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29058	11041-20000-18765	1655 N GILCREST DR	90210	5	147B165    41	4352004014	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.10154	-118.40215	New single family residence.  Full Plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29059	17041-10000-02436	5200 N LANKERSHIM BLVD	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	T-24, PC FOR ENERGY ONLY. TI AT GROUND FLOOR LOBBY FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2003 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29060	16041-20003-30985	18957 W CARMEL CREST DR	91356	3	162B121   162	2177048014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	34.14115	-118.5437	4.27.2017 - Plan check for modifications to approved set. Revise roof layout, and reduce total number of pv modules to (31). Change model/manufacturer of pv modules, new modules have a rating of 325W. Changes clouded.========02/03/2017 Changes to an approved set of plans. System size has increased from 7.6 kWac to 10.6 kWac with the addition of (1) inverter, (2) modules, and (1) load center, for a total of (2) inverters, (34) modules, and (2) load centers. System is a battery back-up PV system.*****Previous Work Description*****PV1INSTALL ROOF MOUNTED PV SYSTEM WITH BATTERY BACK UP SIZED 7.6KW INTERCONNECTED WITH MSP.$10.37 permit fee is due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29061	13041-10000-36178	1100 S SAN PEDRO ST I04	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.03515	-118.25194	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29062	18041-20000-10510	10828 W VIA VERONA	90077	5	147B145   114	4377037017	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.09911	-118.4588	Plan check for the installation of (2) Tesla PowerWalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29063	18041-30000-33326	9966 W BEVERLY GROVE DR	90210	5	144B157    94	4356014025	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	05/22/2023 12:00:00 AM	ADDRESS	34.09416	-118.42663	Plan check for power only. Project site is an existing single-family dwelling. Project scope is a remodel and addition. Work includes a new 800 amp service.Note: Building permit has been issued under 16014-30000-00681. Electrical permit fees have been included in the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29064	15041-10000-20165	1616 S GAFFEY ST	90731	15	012B197   471	7454034031	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.01	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	33.72944	-118.29222	Medical office TI.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29065	15041-20000-36315	9950 N CABANAS AVE	91042	7	201B205   327	2571009057	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	ADDRESS	34.24863	-118.2687	PV1, roof mounted solar panel, 6.84kW.(24)modules: SW285 Mono(1)inverter: SE6000A-USDC-DC Converter is used: OP300-MVStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29066	14041-10001-15560	12303 W MONTAGUE ST	91331	7	204B165   175	2537005016	M2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.2551	-118.40128	(((   changes made to previosly approved set as indicated by clouds and new circuits and panel  M.Z   12-22-14  ))))    T.I. for existing 1 story office building w/ mezzanine floor.  Power and lighting plan check.  Total area = 57,800 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29067	19041-10000-42182	6856 N TUJUNGA AVE	91605	2	183B173   205	2319006001	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.19554	-118.37887	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLYOUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29068	17041-20000-43978	18237 W LOS ALIMOS ST	91326	12	207B125   200	2715010021	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.26557	-118.53125	"""20.55$ permit fees due to senate bill 1222""PV1.  Install 11.05 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (34) modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29069	13041-10001-32970	22774 W MACFARLANE DR	91364	3	171B097   948	2075017030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	34.16176	-118.62296	Expedited RSES plan check per applicant request.[][]PV1, Install  12.5 kw DC roof-mounted solar array for a  house interconnect with service panel.(2)Transformerless inverters: SOLAREDGE SE6000-US and SOLAREDGE SE5000-US . 50 modules: Trina Solar TSM-250PA05.18.[][[]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29070	17041-10000-40964	12908 W DISCOVERY CK	90094	11	102B157   349	4211027***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Expired	09/11/2023 12:00:00 AM	ADDRESS	33.97306	-118.42032	PC for 3.8kW roofmounted PV system. Installing 13 modules with optimizers and one central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29071	14041-20000-24264	10464 W PENROSE ST	91352	7	195B177   241	2404003006	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.2321	-118.35954	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.8kW.(1) Power-One PVI-4.2-OUTD-S-US-A transformerless inverter(1) Power-One PVI-3.6-OUTD-S-US-A transformerless inverter(39) REC Solar REC260PE(BLK) pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29072	17041-10000-18795	6300 W WILSHIRE BLVD 640	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Title 24 plan check.  T.I. to office space #640 in existing commercial highrise building.  Existing subpanels to remain with new lighting and receptacles.  Total area = 5,376 sq. ft.       Building permit #17016-10000-12179	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29073	13041-10000-03065	350 S BIXEL ST # 120	90017	1	132A209    99	5152014038	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.05673	-118.26007	PLAN CHECK T24 ENERGY AND EMERGENCY FOR INTERIOR TENANT IMPROVEMENT GROUND FLOOR OFFICE. #120. PERMIT TO RELOCATE EXISTING LIGHTING,  EXIT SIGNS, AND ADD RECEPTACLES ON EXISTING CKTS .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29074	14041-20001-03135	202 N GRAMERCY PL	90004	4	138B193   763	5516020011	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.07484	-118.31233	(((Expedite fees)))PV1  SYSTEM WITH MICROINVERTERS AND CENTRAL INVERTER. 1.1KWAC OF MICROINVERTER WITH 3.5KWAC CENTRAL INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29075	13041-10002-16723	3553 E BESWICK ST	90023	14	120A227   144	5191012031	(T)(Q)RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.02223	-118.19931	[[[6/30/14]]]] CHANGES TO APPROVED SET PER INSPECTORS REQUEST. DELTA 2 CHANGES ONLY. ADDITION OF 14 TAMPER SWITHCES, 10 WATERFLOWS, 9 SMOKE DTECTORS AND 2 RELAYS.CHANGES TO APPROVED SET. CHANGES IN LOCATION OF 4 FIRE ALARM DEVICES. DELTA 1 CHANGES ONLY.installation of fire warning system with central station monitoring	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29076	15041-20000-18129	12780 N CHALON ROAD	90049	11	141B137    49	4493005011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	34.08327	-118.49819	Plan check for power addition to the existing house including GYM, SPA,Pool,Dance studio and etc. for 2,000A service and new 100KW Standby Generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29077	11041-20000-15970	22651 W CALVERT ST	91367	3	177B097   362	2039018003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.18115	-118.62064	single family Roof top solar 8.82 kwop ( Max 2 lb/sf  or  8 lb/sf  if the collector is of the type which inhibits superimposed concentrated loadings).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29078	19041-10000-48293	8036 S DUNFIELD AVE	90045	11	099B165   484	4109008025	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	33.96787	-118.39932	[EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 14.6KW DC/ 11.6KW AC, 40 LG SOLAR MODULES (365), 40 MICROINVERTERS (ENPHASE IQ7+),  AND 1 ENPHASE COMBINER BOX WITH EXISTING MAIN SERVICE PANEL OF 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29079	18041-10001-22642	3437 N TROY DR	90068	4	159B181    43	5579002016	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Issued	01/23/2019 12:00:00 AM	ADDRESS	34.13532	-118.34417	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.52KWac.(37)MODULES-LONGI LR6-60 285M(37)MICROINVERTERS- ENPHASE IQ6-60-2-US MICROINVERTERSNOTE: SOME PERMIT FEES ARE PAID UNDER PCIS#18041-90000-22642	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29080	18041-20000-38523	1532 S HI POINT ST	90035	10	129B173   868	5068018008	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			10/09/2018 12:00:00 AM			PC Info Complete	05/02/2019 12:00:00 AM	ADDRESS	34.04902	-118.36928	3 story 9-unit apartment building.  800A 240/120V 1ph-3w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29081	18041-20000-48206	15611 W KALISHER ST	91344	12	213B145   219	2662008004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	03/16/2019 12:00:00 AM	ADDRESS	34.27677	-118.47214	PV1.  Install 3.04 kW roof mounted grid tied PV system.  (E) 3 kW rated PV system also on site.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29082	16041-10000-01194	4560 W ROSEWOOD AVE	90004	13	141B193  1441	5521024014	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Expired	02/12/2018 12:00:00 AM	ADDRESS	34.07889	-118.30381	PV1, Install 3.18 kW DC roof-mounted solar array, interconnect with service panel. Transformerless. (1) Inverter. : ABB PVI-3.0-OUTD-S-US-Z-A. (12) Modules KYOCERA  KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29083	13041-20000-05441	19314 W OLIVOS DR	91356	3	168B117   195	2175007001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2013 12:00:00 AM	04/19/2013 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.15832	-118.55369	Photovoltaic system on roof of single family dwellling with modules, inverters and PV subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29084	15041-20001-25314	345 S BROADWAY	90013	14	130-5A211 134	5149015020	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.05008	-118.2492	12/08/15 Changes to title 24. adding 4 new led lighting fixtures. permit under pcis#15041-20000-25314(((Title-24 plan check only.  Total area = 1,206 sq. ft.  T.I. to existing commercial space.  New lighting, recepticles, and kitchen equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29085	10041-10000-19183	2105 S FIGUEROA ST	90007	9	123A203   117	5126003026	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM			PC Approved	11/01/2010 12:00:00 AM	ADDRESS	34.03205	-118.2738	New car sales lot. Plan check is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29086	18041-10000-15189	20360 W PLUMMER ST	91311	12	198B113    76	2748022077	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.24252	-118.57752	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29087	14041-20000-17519	2016 N RODNEY DR	90027	4	150B197   445	5590007012	R3-1XL	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.10822	-118.28902	Plan check for energy only. New apartment building - outdoor/corridor lighting, and lighting in parking garage. 4,709 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29088	15041-10001-23491	11985 W BLUFF CREEK DR CAFE	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			Re-Activate Application	11/03/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	(11/2/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE REVISIONS TO THE LIGHTING AND ENERGY CALS.   FULL PC, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER IN THE CAFETERIA. PANELS FOR CAFETERIA ARE COVERED UNDER APP#: 15041-10000-23464,WORKSPACE.    TOTAL SQ. FT. 9971. PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29089	19041-10000-22880	2839 W SAN MARINO ST	90006	1	132B197   903	5077029006	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			06/14/2019 12:00:00 AM			Reviewed by Supervisor	07/15/2019 12:00:00 AM	ADDRESS	34.05511	-118.29019	Full plan check for a new apartment buildings consist of  4-story and 25 unit over a podium structure and basement parking. Scope includes (1) 1000-Amp service, 120/208v 3phase service with a total of (5) typical unit. total lighting area is 15,996-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29090	17041-10000-17074	523 W 6TH ST 4TH FLR-CORRIDOR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24, PC FOR ENERGY ONLY. TI TO 4TH FLOOR CORRIDOR.  SCOPE OF WORK INCLUDES INSTALL NEW LIGHTS ON EAST AND WEST SIDE OF THE CORRIDOR OF AN (E)  COMMERCIAL BUILDING . TOTAL AFFECTED AREA IS 1484 SQ. FT. B#16016-10000-29940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29091	12041-20000-22291	800 W WILSHIRE BLVD #1080	90017	9	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.0493	-118.25841	Change to lighting and receptacles for an existing office space in a high rise building.  Suite #1080 on the 10th floor.  Load is less than 400amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees for new lights and receptacles on existing circuits are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29092	13041-10000-00219	3785 W WILSHIRE BLVD # 2401-#2406	90010		132B193    30	5503030903							Electrical	Electrical	Apartment			01/04/2013 12:00:00 AM			PC Info Complete	02/12/2013 12:00:00 AM	ADDRESS	34.06187	-118.30858	T.I. WORK ON UNIT NO. 2401-2406 Solair Penthouses on the 24th floor.  No work done in the common area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29093	16041-10000-45168	9321 W CHEROKEE LANE	90210	4	153B165   543	4388019027	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2016 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	34.11167	-118.39732	PC FOR POWER. NEW SINGLE FAMILY HOME WITH ATTACHED GARAGE. 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29094	19041-20000-12871	2921 S HADDINGTON DR	90064	5	126B161   710	4318021003	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/01/2019 12:00:00 AM	ADDRESS	34.03735	-118.41183	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 16.08 KW DC/13.44KW AC/14.48KW AC CEC. SCOPE OF WORK INCLUDES (48) LG335N1C-A5 335W PV MODULES WITH (48) IQPLUS-72-2-US MICROINVERTERS, AND A NEW 100A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29095	18041-20001-31209	16743 W SCHOENBORN ST C	91343	12	192B137   231	2689012013	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Issued	05/24/2019 12:00:00 AM	ADDRESS	34.22285	-118.49793	5/1/2019changes to an approved set of plans.  changes noted delta 3.  changes to reflect field conditions.  plan check for power only. ((((Tenant improvement to (E) 2-story commercial building tenant space.  Plan check for power and energy.  Generator supplying additional loads not connected to service.Building permit issued under 18016-10000-13623.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29096	17041-10000-24553	2925 W SUNSET BLVD	90026	13	142-5A205 415	5426004014	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.08345	-118.27357	PC for T24 only for new lights in ice cream shop TI. Installing two 100A panels, new cirucits and new equipment. #17016-10000-18568. Total affected are is 905 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29097	17041-10000-14659	3096 S MCCLINTOCK AVE	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.02647	-118.28575	PC FOR ENERGY. T.I FOR A RETAIL STORE. CONNECTED LOAD < 400AMP. TOTAL AREA 3203 SQ FT. B # 17016-10000-11442	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29098	18041-20000-18499	19520 W STRATHERN ST	91335	3	189B117   370	2105005020	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.2155	-118.55892	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (52) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29099	09041-10001-11844	155 S MAIN ST	90012	14	130-5A213  24	5149001902	PF-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM			PC Info Complete	10/27/2010 12:00:00 AM	ADDRESS	34.05125	-118.24458	TI - first time tenant in core/shell - Parker Center Cafe - Permit is for the addition of new panels, new xfmrs, new ckts, new equipment on the first floor.  P/C is for Power and Energy. Relocating locker room and reducing two lights 10-27-2010.  G.C.  See existing permit application # 09041-30000-11844.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29100	13041-10000-27144	18815 W STARE ST	91324	12	204B121   497	2729016001	RE11-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.25269	-118.54316	PV1.  Install 9 kW DC roof-mounted solar array, interconnect with main service panel.  2 transformed inverters: Fronius IG 5100 NEG and IG 2000 NEG. 36 modules Trina {TSM-250PA05.08}	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29101	18041-10000-23894	360 E 2ND ST 7TH FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC FOR  OFFICE TI ON THE 7TH FLOOR IN A HIGH RISE BUILGING. SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 11841 SQ.FT. B#18016-10000-18669	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29102	14041-20000-27330	8420 N FULLBRIGHT AVE	91306	3	192B113   326	2781023011	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.22317	-118.57715	install roof mounted pv system sized 3.4kw interconnected with msp.(16) hyundai heavy m250 modules(16) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29103	15041-20001-16267	936 S OLIVE ST UNIT 355	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #3 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259.PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29104	13041-20000-13673	13928 N BALBOA BLVD	91342	7	228B137   219	2603025027	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Info Complete	05/24/2013 12:00:00 AM	ADDRESS	34.32344	-118.49127	Plan check for feeder from 100A, 3P breaker on SWBD1 and associated equipment per inspector's request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29105	10041-20000-10428	7317 N RESEDA BLVD	91335	3	186B125   819	2118015009	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Closed	10/22/2010 12:00:00 AM	ADDRESS	34.20355	-118.53632	Plan check power and energy for change of use from office to dental office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29106	11041-10000-24875	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM			PC Approved	11/21/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	Plan submittal to replace lost originals (ONLY), (2) sets.PLAN CHK APPLICATION IS TO REVIEW NEW SET OF PLANS AS AS-BUILT PLANS. ALL CHANGES ARE CLOUDED. ITEMS ARE MOVED AROUND ON THE PANEL SCHEDULES AND ARE RELOCATED  ((((((NEW SERVICES AND FEEDERS TO SUPPLY POWER TO  EXISTING AND NEW STRUCTURES  AT HOTEL BEL-AIR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29107	16041-10001-07789	375 N LA CIENEGA BLVD #135	90048	5	138B173    80	4337012068	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			PC Info Complete	05/19/2016 12:00:00 AM	ADDRESS	34.07806	-118.37692	PLAN CHECK FOR POWER AND ENERGY. FIRST TIME TENANT. BEAUTY SALON. SUITE 135NOTE: PERMIT WAS PAID UNDER MASTER APPLICATION PCIS#16041-30000-07789.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29108	19041-10000-10786	2401 W BRIARCREST ROAD	90210	4	153B169   884	4388016023	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2019 12:00:00 AM			PC Approved	08/05/2019 12:00:00 AM	PIN	34.11265286	-118.39243463	Pc for a new 2-story single family daweling. (Existing 800A service) Scope include 600A, 208/120V,3ph, 4W. 8746 Sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29109	16041-30000-30860	11209 W RICHLAND AVE 1-13	90064	5	123B153   510	4256012001	R3-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Apartment			08/30/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.03288	-118.43303	Plan check for new Fire alarm system in 13 units appartment 4 story building. Total fire alarm devices: 65 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29110	12041-10000-19177	8401 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM			PC Info Complete	09/20/2012 12:00:00 AM	ADDRESS	34.22253	-118.62558	TI IN AN EXISTING LABORATORY. INSTALL NEW PANEL & LOAD. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29111	11041-10000-02930	1717 N GARFIELD PL 1-90	90028	4	148-5A193 110	5544003002	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			02/15/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.10227	-118.31103	NEW CONSTRUCTION APARTMENT COMPLEX WITH SPACE ON FIRST FLOOR FOR FUTURE RETAIL AREA.  120 UNITS, 5 STORY WITH ROOF AREA.  FULL PLAN CHECK.  A variance to separate the fire alarm system plan check and permit from the electrical plan check and permit was submitted on June 17, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29112	16041-20000-21211	10343 W DIAMOND ST LOT 10	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29113	19041-10000-10280	2267 W 31ST ST	90018	10	120B189   490	5052022015	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.02658	-118.31713	Plan check for a 3.8KW AC / 4.13KW DC roof mounted system adding on to an existing PV system. Scope includes (1) inverter, (1) subpanel, and (14) modules interconnecting to the line side of the service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29114	13041-10000-15233	2298 N GLOAMING WAY	90210	5	153B165   324	4388006009	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.11415	-118.40142	PV1 9.88KW MICROINV 2 STORY. NONSTD. ROOFMOUNT.[ 38 MICRO INVERTER  M215-60-2LL-S22] [MODULE: 33 AUO Green triplex PM250M00 260WP]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29115	19041-10000-20609	21215 W BURBANK BLVD	91367	3	174B105    88	2149019019	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.17353	-118.59268	Full plan check for office T.I located at level 1-4 of a (6) story building. Scope includes new lighting and equipment with a total lighting area of 151,107-SQ FT.Note to plan checker. there are (2) ENGINEER ON THE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29116	17041-10000-43752	1344 N SERRANO AVE	90027	13	147A195   265	5544033064	[Q]R4-2	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Issued	12/06/2017 12:00:00 AM	ADDRESS	34.09571	-118.30689	REMOVE OUTDOOR METAL HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29117	15041-10000-24971	1990 S BUNDY DR UNIT 340	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.03419	-118.45559	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN SUITE 340. TOTAL SQUARE FOOTAGE 5975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29118	18041-10000-38220	750 S LAMAR ST WASTEWATER-TREATEMENT	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (J) WASTEWATER TREATMENT10 OF 10BUILDING PERMIT 13010-10000-0284?	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29119	17041-20000-11996	1031 S WOOSTER ST PV-1	90035	5	132B169   288	4332016035	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.05827	-118.3827	PV2.  Install roof mounted PV system sized 41.24 kW.  (135) modules with (3) 10 kW and (1) 7.6 kW SolarEdge inverters.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29120	14041-10000-25070	5520 N KESTER AVE	91411	4	174B149  1026	2249028003	[Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.1708	-118.45723	New roof mounted PV system with 2.75KW.  System consists of 9 moduls (Kyocera KD250), Optimizers (300W), and 1 inverter (Solares SE3000A-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29121	17041-30000-26551	726 N HUDSON AVE #1-17	90038	4	141B185   469	5533035020	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			08/03/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.08412	-118.33193	Plan check for new Fire alarm system for 17 units appartment building. Total fire alarm devices: 143 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29122	14041-20000-05762	10877 W WILSHIRE BLVD Suite1401-Suite1403	90024	5	132B153   297	4360003029	[Q]C4-3-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.05934	-118.44254	T24 FOR EXISTING OFFICE BUILDING. TOTAL SQRFT 2500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29123	14041-20000-22656	222 W 6TH ST SUITE R-09	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM			PC Info Complete	08/20/2014 12:00:00 AM	ADDRESS	33.73887	-118.28305	TENANT IMPROVEMENT TO AN EXISTING COMMERCIAL BUILDING.  TITLE 24 ENERGY ONLY. ADDING EMPTY PANELS FOR FUTURE LOADS FED FROM A 45KVA TRANSFORMER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29124	14041-20000-34450	1999 S AVENUE OF THE STARS #2550	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 25TH FLOOR. OFFICES, NO CHANGE IN OCCUPANCY. 7226 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29125	12041-20000-27607	3531 N MULTIVIEW DR	90068	4	159B177   573	2425012004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.12998	-118.3629	New rooftop photovoltaic system for an existing single family residence.  System uses Enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29126	15041-20000-26248	15057 W PLUMMER ST	91343	7	198B145    19	2650002001	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Closed	11/22/2022 12:00:00 AM	ADDRESS	34.24288	-118.46067	Plan check for Title 24 only based on 2008 energy code per building submmittal. Total indoor area: 4,545 sqft. Total outdoor area: 14,465 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29127	17041-20000-03010	12701 W VAN NUYS BLVD	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.27621	-118.41056	TI to (E) commercial office space in office/warehouse space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29128	19041-30001-18841	11812 W SAN VICENTE BLVD Ste 505	90049	11	129B145   113	4265018016	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.0528	-118.4684	06/11/2019 Plan check for Title 24 only. Project site is a tenant suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 2,838 sq. ft.Note: Building permit has been issued under 19016-10000-13174*****Previous Work Description*****EXISTING TENANT REMODEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29129	15041-20000-15316	6776 W HOLLYWOOD BLVD	90028	13	148-5A185 156	5547012002	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.10131	-118.33828	Title 24 plan check only.  Total area = 4,029 sq. ft. (indoor) + 216 sq. ft. (indoor)  T.I. to existing McDonald's.  New lighting for dining area and exterior.  2008 energy standards used (building application #14016-10000-05143)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29130	11041-10000-18112	800 S HOPE ST	90017	14	129A209   202	5144020900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM			PC Approved	08/25/2011 12:00:00 AM	ADDRESS	34.0463	-118.25904	TI TO AN EXISTING OFFICE BUILDING ON THE 1ST FLOOR OF A HIGH RISE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29131	19041-20000-08178	202 S MAIN ST	90291	11	111B141   444	4286003001	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Issued	06/13/2019 12:00:00 AM	ADDRESS	33.99763	-118.47899	Plan check for power and energy for mixed use existing building and 1 dwelling unit,  new service 800ATotal area: 3989 sq ft B#18016-30000-13039	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29132	18041-30000-29048	14464 W VENTURA BLVD	91423	4	166-5A151 155	2266001031	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	09/02/2021 12:00:00 AM	ADDRESS	34.15065	-118.44811	Power plan check for a plan located in a hazardous site. SCOPE INCLUDES  A REPLACEMENT OF ONE (1) DOUBLE-SIDED GASOLINE DISPENSER WITH ONE (1) DOUBLE-SIDED HYDROGEN FUEL DISPENSER AND ADDING  HYDROGEN EQUIPMENT TO THE EXISTING GAS STATION.NOTE. fee is provided by applicant. Plan checker need to verify final fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29133	18041-20001-34710	14078 W HOYT ST	91331	6	201B153    49	2645021040	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.2515	-118.43998	10-22-2018 Changes to an approved set of plans, changes include PV modules layout on roof. Changes has been clouded. Plan check only.Fees $0 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29134	17041-20000-45520	9639 W GREEN VERDUGO DR	91040	7	204B181   249	2545002002	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Issued	12/19/2017 12:00:00 AM	ADDRESS	34.25427	-118.34123	Plan check for solar pv system w/roof-mounted array on SFD. standard plan.2.88kW ungrounded system.(12) EnPhase M250 microinverters.(12) 260W pv modules.Owner-Builder.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29135	10041-10000-15329	3780 S FIGUEROA ST	90007	9	117A201     4	5037029001	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM	08/06/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.01629	-118.28251	T.I. to existing building.  Install new general/emergency lighting in recreation room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29136	14041-10000-14345	7126 N FIRMAMENT AVE	91406	6	183B145   124	2222035032	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.20009	-118.47227	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 8.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29137	18041-10000-44344	1208 S ABBOT KINNEY BLVD	90291	11	108B145  1220	4238003043	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	33.99125	-118.46882	PLAN CHECK FOR LIGHTING ONLY, T-24. INTERIOR & EXTERIOR T.I. OF (E) RETAIL SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 808	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29138	19041-20000-34137	7114 N RESEDA BLVD	91335	3	183B125   318	2125001016	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.19984	-118.53581	CHANGE OF USE TO RETAIL PLAN CHECK FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29139	18041-10000-00031	4228 E VERDANT ST	90039	13	159B205   743	5594006030	[T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Issued	01/02/2018 12:00:00 AM	ADDRESS	34.1314	-118.26446	PC FOR A FIRE ALARM SYSTEM FOR A TWO STORY CHURCH. SCOPE INCLUDES 85 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29140	17041-20000-38496	11927 N ANCONA WAY	91326	12	216B109   343	2701086007	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.28934	-118.58584	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29141	17041-10001-46351	850 S GRAMERCY PL	90005	4	132B193   776	5092025030	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Issued	07/22/2019 12:00:00 AM	ADDRESS	34.05648	-118.31308	DELTA 1 CHANGES TO APPROVED SET DUE TO CHANGES TO THE DAYCARE LAYOUT. SCOPE INCLUDES ADDITION OF 24 DEVICES. PANEL SCHEDULE AND BATTERY CALCULATIONS ARE UPDATED ACCORDINGLY. Original scope:  PC for FA system for 4 story 18 unit apartment building. Installing 120 devices with one fire alarm panel, three rps panels and one annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29142	11041-20000-05638	9836 N SHOUP AVE	91311	12	201B101   184	2727005032	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	34.24901	-118.61463	ROOF MOUNTED PHOTO VOLTAIC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29143	13041-10000-23469	1813 N WINMAR DR	90065	1	150A219   322	5464026006	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.10318	-118.22603	PV1 2.45KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: SOLAREDGE SE3000A-US] [( 10) MOD: TRINA {TSM-245PC05.18}]. Equipment to be field verified to see if physical protection is required.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29144	17041-20000-46465	18637 W NAU AVE	91326	12	213B121   367	2871011040	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	34.28089	-118.53975	Plan check for solar pv system w/roof-mounted array on SFD.10.4kW ungrounded system. (1) 6.6kW inverter. (1) 3.8kW inverter.(40) 300W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29145	11041-20000-13931	14726 W LULL ST	91405	6	186B149   141	2210027034	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	09/20/2011 12:00:00 AM	ADDRESS	34.2092	-118.45407	Plan check T24 Energy (general/emergency) lighting for existing commercial building. Permit for (14) branch ckts. Plan check for 600A service power only under #11041-20000-11608	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29146	11041-10002-20630	1118-1120 E LAKE ST BLDG 25	90291	11	111B145   161	4243001039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.00361	-118.45925	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29147	14041-10000-18943	2716 W OLYMPIC BLVD	90006	10	129B197   223	5078010028	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM			PC Approved	08/25/2014 12:00:00 AM	ADDRESS	34.05243	-118.29218	plancheck for t24 energy.  Adding exterier led sales frontage accent lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29148	12041-10002-07193	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			01/10/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	PLAN CHECK FOR DELTA 2, 3, AND 4 REVISIONS TO APPROVED PLANS. TI FOR PRIVATE PHARMACY SCHOOL. PLAN CHECK FOR POWER & ENERGY. NEW PANELS, LOAD & CIRCUITS. 38,000 FT OF ENERGY.  ORIGINAL PHARMACY TI PERMIT NUMBER 12041-10000-18381 AND CORE & SHELL UNDER 12041-10000-07193	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29149	15041-10000-06190	4526 W CUTTER ST	90039	13	165B201   127	5593009017	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.14949	-118.2747	IN STORAGE AREA, RETROFIT EXISTING LUMINAIRES TO LED USING RETROFIT KITSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29150	11041-20002-26413	17947 W CHATSWORTH ST Bldg. L	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.265	-118.52509	Delta 1Changes from previously approved plans.  1)  provide#3/0 grounding electrode conductor and #6 bonding conductor2)  provide signage automatic control3)  provide 30A 1P 120v switch for water heater4)  relocate automatic time switch bypass timer to front entrance5)  relocate lighting switch bank6)  delete items for PV system7)  revise notes for panic hardware at electrical room door8)  reduce size of circuit breakers for RTU units9)  delete photocell bypass for signage controlPermit was previously issued under PCIS 11041-20000-26413.(****Provide 1600 A new service with 5 service disconnecting means, for a remodel of an existing commercial building.  The remodel is for exterior building lighting, and interior spaces L1 and L4.  Spaces L2 and L3 will be part of future work to be done by the tenants.****)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29151	14041-10002-00855	6417 W SELMA AVE	90028	13	148-5A187 302	5546007022	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Closed	01/04/2017 12:00:00 AM	ADDRESS	34.09988	-118.33008	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED. REVISED SINGLE LINE DIAGRAM. EVERY FLOOR HAS PANEL FOR UNIT CIRCUITS. REVISED DISTRIBUTION BOARD RATINGS ALL 1000A. REVISED GENERATOR SIZE. REVISED FIRST FLOOR AND 10TH FLOOR LAYOUTS. NEW EQUIPMENT HAS BEEN ADDED. PERMIT FOR INCREASED IN CIRCUITS AND LIGHTING CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29152	16041-10000-28989	2005 W PICO BLVD	90006	1	129A201   230	5136023031	(Q)CM-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.04702	-118.28177	Zero permit fee per California Senate Bill 1222.PV-2 Plan check for commercial 80KW solar system with 289 PVmodules and 1 inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29153	18041-10000-05183	1177 S WEST BLVD	90019	10	129B185   241	5083012010	R3-1	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Issued	02/12/2018 12:00:00 AM	ADDRESS	34.05248	-118.33238	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.5KWdc / 5.0KWac. (20)MODULES-SOLARCITY STANDARD SC325(20)OPTIMIZIERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE5000H-US000SNU2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29154	11041-20000-19378	7900 N WOODMAN AVE	91402	6	189B157  1033	2214026***	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Expired	10/07/2013 12:00:00 AM	ADDRESS	34.21407	-118.43069	Replacement of an existing fire alarm panel.  Contractor states he is replacing like for like.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29155	14041-10000-24456	10955 W PEORIA ST	91352	7	201B173   311	2538014015	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.24668	-118.36936	PV1, INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29156	17041-30000-20157	5645 N FARMDALE AVE	91601	2	174B169   670	2338028004	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.17328	-118.38117	Plan check for a fire alarm system for a 44-unit apartment building. Fire alarm system consists of (1) FACP, (3) RPSs, (1) annunciator, and (149) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29157	16041-10000-35011	1100 E 14TH ST	90021	14	123A211   434	5132022001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.02925	-118.24904	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW SERVICE UPGRADE OF 800 AMPS AND (1) PANEL 800A  AND (1) LIGHT FIXTURE. TOTAL AFFECTED AREA IS 84 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29158	18041-20000-07420	649 N RADCLIFFE AVE	90272	11	126B125   441	4412014035	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.04238	-118.5309	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consists of (15) AC PV modules, (3) load centers, and (2) Tesla PowerWalls.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29159	12041-10000-15748	1 W WORLD WAY	90045	11	090B165    93	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	06/17/2013 12:00:00 AM	PIN	33.94415688	-118.4024579	"TWO TEMPORARY INSTALLATIONS EACH OF (2) 3"" SCH 80 CONDUIT RISERS WITH FEEDERS SUPPLIED FROM  DISCONNECTS ON MCCST (NORTH) AND MCCSU(SOUTH) .THESE INSTALLATIONS ARE IN THE CORE OF THE TBIT BUILDING AND ARE TO BE USED TO SUPPLY POWER TO POWER SKID FOR THE TERRAZIO PROJECT ON THE 5TH,4TH 3RD OF THE NORTH SECTION AND 5TH, 4TH, 3RD, AND 1ST FLOORSOF THE SOUTH SECTION OF THE TBIT CORE.   New TBIT core install (2) 3"" PVC conduits only"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29160	19041-10000-15772	10250 W SANTA MONICA BLVD 2900	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK  FOR A TI OF A BAKERY AT WESTFIELD CENTURY CITY. ( FIRST TIME TENANT)SCOPE INCLUDES NEW TRANSFORMER (75KVA), EQUIPMENT, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 712 SQ.FTB# 19016-10000-12591	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29161	14041-10000-16937	21402 W WYANDOTTE ST	91303	3	186B105   885	2111017037	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.2027	-118.59799	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 3348 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29162	13041-20001-27236	11038 N CHIMINEAS AVE	91326	12	210B125   466	2715013016	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.271	-118.52847	((EXPEDITE FEES))PV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. NON STANDARD PLAN. MICROINVERTERS. SYSTEM SIZE: 7.0 kW.(28) CANADIAN SOLAR 250 MODULES(28) ENPHASE 215 MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29163	17041-10000-35480	5715 N FIGUEROA ST SUITE 102	90042	1	151-5A229 170	5492001015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.10994	-118.19246	Full plan check for a first time tenant  (new market) T.I. Total energy plan check area is 1135 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29164	15041-20001-23696	15760 W STRATHERN ST Bldg. 1	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			PC Approved	06/03/2016 12:00:00 AM	ADDRESS	34.21559	-118.47701	[[5/23/16 CHANGES TO APPROVED SET. CHANGES TO T24 INDOOR LIGHTING]]Plan check for power and energy.  Total area = 21,532 sq. ft. (indoor) + 6,632 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29165	17041-10002-19121	802 E E ST	90810	15	030B209  1214	7424015061	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	PIN	33.77558988	-118.25229481	Changes to an approved set of plans, scope of work includes the addition of restrooms and electrical room to the scope of work. Total sq. ft. 1786.*****PC for power and energy for addition of recycling building to existing manufacturing plant. PC for new 1600 A  480/277V service in methane zone. Total area of 42000 sqft. Building #16010-40000-04106.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29166	15041-10000-11424	11500 W OLYMPIC BLVD 300	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.03624	-118.44415	Energy plan check for  ,CONTROL RECEPTACLES only, office T.I  located in the 3rd floor of a high rise building. Total area is 13,183-SQ feet. Note: lighting plan is on a seperated permit (# 15041-10000-06267)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29167	12041-20000-18786	7325 N MEDICAL CENTER DR SUITE 103	91307	3	186B097   830	2021014040	(Q)CR-1VL, CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.20328	-118.62963	Plan check for power and energy and emergency lighting.  INTERIOR NON STRUCTURAL TENANT IMPROVEMENT TO REMODEL RESTROOM, PRE-OP, LINEN ROOM , RECOVERY, STORAGE & HAZARDOUS WASTE ROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29168	13041-10004-16949	7528 N KRAFT AVE	91605	6	186B169   384	2316010026	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.20742	-118.38001	REVISIONS TO AN APPROVED SET OF PLANS.  ADDITION OF AN EGC TO THE POWER ONE PV15000 UNGROUNDED INVERTER.PV-1 Plan check for 11.5KW roof mounted photovoltaic system. Ungrounded system using Power-One inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29169	14041-20000-23459	7509 N WISCASSET DR	91307	12	186B085    33	2017033011	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	PIN	34.20924095	-118.66003114	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER, USING STANDARD PLAN. USING POWER OPTIMIZERS. TOTAL OF 28 MODULESFIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29170	12041-10000-10461	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	Change to Indoor lighting, new transformer and 100A panel with circuits for a medical clinic.  Full plan check.  Not a state licensed building, per engineer.  NOT CHECKED FOR OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29171	14041-10000-24367	3507 N SCADLOCK LANE	91403	4	159B145   207	2279030006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.13449	-118.4707	PV1 Standard plan. 7.9KW roof-mounted system including (31)Kyocera KD255 modules and one Solaredge SE6kw inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29172	19041-10000-02305	2011 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.06159	-118.20463	FULL PLAN CHECK FOR POWER AND ENERGY. PARTIAL TENANT IMPROVEMENT TO  (E) RESEARCH LABORATORY/LECTURE HALLBUILDING BASEMENT LEVEL THROUGH 9TH FLOOR . SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. CONNECTED LOAD > 400AMPS. TOTAL SQ. FT. 7554B# 19016-10000-01438	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29173	16041-20001-23452	11159 W LA MAIDA ST	91601	2	168B173   267	2353020022	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	07/18/2016 12:00:00 AM	ADDRESS	34.15886	-118.37417	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29174	16041-30000-29096	1431 S ARMACOST AVE 1-13	90025	11	126B145   300	4263031012	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.04303	-118.46148	Plan check for Fire alarm system in 13 units appartment. Total fire alarm devices: 71 and FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29175	13041-10001-08681	11546 W CANTON DR	91604	2	159B169   358	2377016020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.13288	-118.38537	][][] CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGE IS FOR THE RELOCATION OF THE PANELS][][][][PV1 ROOF MOUNTED SOLAR INSTALLATION ON 2 STORY FAMILY DWELLING. 48 MODULES. SYSTEM SIZE IS 11.76 KW.. USING TWO INVETERS WITH TWO STRINGS PER INVETER. [INVETER: SMA AMERICA # SUNNY BOY SB6000US AND SMA AMERICA # SUNNY BOY SB5000US  |||| MODULES: REC SOLAR # REC245PE(BLK)]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29176	10041-20000-02720	15853 W MONTE ST 107C	91342	7	225B141  1523	2604003043	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM	04/07/2010 12:00:00 AM		Permit Finaled	07/13/2010 12:00:00 AM	ADDRESS	34.31022	-118.47637	s.107C tenant developmentexist.permit 10041-90000-01581	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29177	16041-10000-23174	10046 N SAMOA AVE	91042	7	202-5A199  24	2568006036	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			07/01/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.25157	-118.28721	install new fire alarm system for a new 2-story building, 222 fire alarm devices and one fa panel and 2 communicators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29178	17041-20000-28132	333 S BERENDO ST	90020	10	135B197   339	5502006022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.06807	-118.29431	PV2.  Install 20 kW roof mounted grid tied PV system.  (65) modules with (2) Fronius Primo 10 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29179	12041-10000-17631	154 S ORANGE DR	90036	5	138B181  1109	5513016011	R2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.072	-118.34173	New, 6kw rooftop, photovoltaic system for an existing single family residence.  System uses Enphase M215 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29180	18041-10000-18206	7054 N TUNNEY AVE	91335	3	183B117   306	2130023007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.19899	-118.55687	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 5.52KWAC SCOPE INCLUDES 23 MODULES WITH MICROINVERTS AND COMBINER BOX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29181	13041-10002-34186	100 S SANTA FE AVE ste #1000	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.04798	-118.23239	Plan check for power and energy. 1st time tenant. TI for  Metrolink office. 6 story mixed use - not high rise. Located in methane zone.(((((( changes made to previously approved set.  8-15-2014 m.z ))))))))panel A1 sub fed from  panel A, 1 ckt added. 9-04-14 mz	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29182	12041-10000-26458	815 N LA CIENEGA BLVD	90069	5	141B173   154	4337002039	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.08582	-118.37662	Plan check indoor lighting T24 Energy/emergency for existing retail store. Outdoor lighting on seperate permit. New electrical system with 400A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29183	18041-20000-46684	15301 W VENTURA BLVD u2	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.15411	-118.46654	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connecte load < 400 amps.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29184	19041-10000-46127	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	04/29/2020 12:00:00 AM		Issued	04/29/2020 12:00:00 AM	ADDRESS	34.02201	-118.28947	FULL PC FOR A TI (FIRST TIME) IN ANEXISTING CORE AND SHELL SPACE. SCOPE OF WORK INCLUDES (3) NEW PANELS CONNECTED TO AN EXISITNG ELECTRICAL SYSTEM. TOTAL AFFECTED AREA IS 19,161 SQFT. PER BUILDING ((B#19016-10000-36258))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29185	11041-10000-15972	10711 N GLENOAKS BLVD	91331	7	207B165   161	2536015035	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.26405	-118.40156	T.I.  Exisitng 7-11.  Renovating the light fixtures in the retail area only.  Replacing the light fixtures with LED's.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29186	14041-10000-15623	515 S FLOWER ST 41ST FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM			PC Info Complete	07/09/2014 12:00:00 AM	ADDRESS	34.05134	-118.25661	permit to be pulled at EPC counter only. PC FOR  ENERGY only. T.I. FOR A OFFICE BUILDING. NEW PARTITION WALLS TO CREATE 5 NEW OFFICES. TOTAL  AREA 1099 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29187	19041-20000-04481	20061 W SATICOY ST	91306	3	186B113   176	2106006041	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.20848	-118.57071	Plan check for Title 24 Energy only Tenant Improvement on existing space. Total area: 419 sq ft. B#18016-20000-30355	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29188	17041-20000-35925	7223 N TYRONE AVE	91405	2	183B153   105	2217003040	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Apartment			10/06/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	03/15/2019 12:00:00 AM	ADDRESS	34.20174	-118.44468	Plan check for power and energy. New 4-story, 38-unit apartment building with parking garage. 1,200A 120/208V 3ph 4w service. 13 typical units. T24 area - 37,773sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29189	17041-10000-20348	8210 N ORION AVE	91406	6	192B145   532	2654038046	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.22	-118.47197	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29190	19041-10000-49010	1300 N VERMONT AVE 501 & 502	90027	13	147B197   892	5542017032	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	05/12/2020 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.09579	-118.29152	TI IN AN EXISTING COMMERCIAL (MEDICAL OFFICE) AREA IN SUITE #501 & 502. AFFECTED AREA: 2160 SFT.BLDG PERMIT: 19016-10000-37189	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29191	11041-20000-22091	11415 N ILEX AVE	91340	7	213B153   192	2616018019	M1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.27705	-118.43569	UPGRADE SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29192	17041-10000-46098	1950 S AVENUE OF THE STARS	90067	5	132B161    33	4319002055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM			PC Info Complete	02/20/2018 12:00:00 AM	ADDRESS	34.05947	-118.4164	PC FOR METHANE MITIGATION AND DETECTION SYSTEM FOR NEW  41 STORY APARTMENT BUILDING. SCOPE INCLUDES NEW SYSTEM  INSTALLED  IN LEVELS B1 THROUGH B3. TOTAL DEVICE COUNT 38 DEVICES AND PANEL (COUNT ON SHEET 4.0). B#17010-10000-03447	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29193	17041-10001-08165	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	33.97954	-118.42015	Changes to approved set due to field changes. This is plan check only. Scope of work is changes in device routing and type. No additional devices added. Permit under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29194	15041-20000-40226	10979 W PENROSE ST	91352	6	195B173   271	2408028016	[T][Q]CM-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM			Reviewed by Supervisor	12/08/2015 12:00:00 AM	ADDRESS	34.23014	-118.37033	Plan check for power and energy.. 800A 277/480Y Service upgrade for (E) one-story commercial facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29195	16041-10000-30979	5214 E BORLAND ROAD	90032	14	138A235   217	5221024008	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.07216	-118.17057	ROOF MOUNTEDPC FOR PV SYSTEM. USING MICROINVERTERS. TOTAL OF 26 MODULES WITH ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29196	13041-20000-28668	21929 W VENTURA BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	PIN	34.16940578	-118.60503747	Change of use from retail to beauty salon & T.I.  Load is less than 400 amps.  PLA N CHECK ONLY for Energy.  NO EMERGENCY LIGHTS PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29197	18041-20000-18025	20749 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.29513	-118.58626	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29198	12041-10000-27118	12959 W CORAL TREE PL	90066	11	102B157    34	4211008024	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	33.97747	-118.42395	applicant paid with check. recalculate fees . MTanEXISTING TI. NEW SWITCHBOARD 2500A. PLAN CHECK FOR POWER AND ENERGY. METHANE. 59810 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29199	19041-20000-44215	8953 W MULBERRY DR	91040	7	207B185   265	2547028053	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.26408	-118.32724	PV1. INSTALL 10.89 KW DC PV SYSTEM WITH (33) MODULES/MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29200	18041-10000-40725	17535 W DONMETZ ST	91344	12	210B129   112	2711007008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.27464	-118.51661	EXPEDITE FEES FOR : NEW 23.465 KW ROOF MOUNTED PV SYSTEM WITH 988 SOLAR PV MODULES ON A SINGLE FAMILY HOME AND 40.5KWH ENERGY STORAGE SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29201	10041-10000-21361	14540 W BLYTHE ST	91402	6	189B149   397	2210022055	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Public Safety Only			10/26/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.21511	-118.45028	1 for 1 replacement of a fire alarm panel for a fire warning system in an apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29202	13041-10001-30817	20231 W VIA SANSOVINO	91326	12	219B113   314	2701062029	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	34.29769	-118.57367	Expedited RSES plan check per applicant request. PV1, Install 10.75 kW DC roof-mounted solar array, interconnect with service panel. Multiple inverters: Solaredge SE 6000A-US and Solaredge SE 3800A-US. 43 modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29203	16041-10002-22239	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	"Changes to an approved set of plans. All changes are clouded under delta 3. All changes to reflect what is on the field. Changes include removing loads for ""DP5"" for future use.  No loads will be connected to distribution board ""DP5"" at this time. Existing services ""MS1"" and ""MS2"" will remain in place. Note: PC only. Permit has been paid under PCIS#16041-20000-22239"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29204	19041-20000-09478	10961 N GOTHIC AVE	91344	12	210B137   704	2680022028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.26988	-118.48923	PLAN CHECK FOR ADDITION OF A 5KW AC POWERWALL SYSTEM ADDITION TO EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29205	17041-20000-06303	20704 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	06/17/2021 12:00:00 AM	ADDRESS	34.29448	-118.58483	pv1install roof mounted pv system sized 5.7kw (ACM) interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29206	14041-10000-06143	1173 S HAYWORTH AVE	90035	5	132B173  1225	5087026015	R2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.05404	-118.36705	PV1,INSTALL 5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.6-OUTD-S-US-Z-A(21) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29207	17041-10000-06071	4212 N COLDWATER CANYON AVE	91604	2	165B161   999	2375021020	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	10/18/2018 12:00:00 AM		Issued	10/18/2018 12:00:00 AM	ADDRESS	34.14561	-118.41355	PC for energy only. Change of use from auto repair to retail store as part of existing gas station. Adding New switchboard rated at 400 amps. New lighting and power. Total area: 2878 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29208	11041-10000-00987	4550 W PICO BLVD bldgs  C&D	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	ADDRESS	34.04842	-118.33486	NEW METHANE DETECTION SYSTEM. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29209	13041-20001-31345	10811 W FOOTHILL BLVD	91342	7	210B173    62	2529021006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.27469	-118.36665	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29210	19041-10000-22126	10701 W WILSHIRE BLVD 1-119	90024	5	132B153   104	4360011***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Issued	06/11/2019 12:00:00 AM	ADDRESS	34.06104	-118.43628	PC for  new FA system. system includes 1 FACP and 57 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29211	12041-20000-25578	19837 W RINALDI ST	91326	12	210B113   191	2701040010	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM			PC Approved	12/05/2012 12:00:00 AM	ADDRESS	34.27535	-118.56687	Plan check for energy only. Emergency lighting is existing and subject to field inspection. 5024 sqft orignally 463, same price for plan check so no additional charge.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29212	16041-10000-09057	5156 E ALHAMBRA AVE	90032	14	138A235   175	5216022006	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.07259	-118.17332	Service Upgrade to 800A. Core & Shell, all loads are for future. PC for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29213	13041-20000-19056	1210 W CHANDLER ST	90744	15	036B201   252	7414018012	R1-1XL	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	33.79578	-118.27782	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW. USING 16 MODULES. CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29214	12041-20000-01439	1990 S BUNDY DR s.430	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.03419	-118.45559	office t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29215	16041-10000-17649	1830 S FIGUEROA ST	90015	9	124-5A205 176	5126009003	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.03489	-118.27149	TITLE 24 LIGHTING. TOTAL= 6320 SQ. FT. ON EXISTING AUTO REPAIR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29216	13041-10000-21371	705 W 34TH ST	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			Corrections Issued	08/08/2013 12:00:00 AM	PIN	34.02214675	-118.28186522	INSTALL A 10' X 5.75' PRE-FAB STEEL PARKING LOT GUARD BOOTH ON NEW CONCRETE SLAB WITH BOLLARDS AROUND.  TITLE 24 PLAN CHECK FOR BOOTH LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29217	10041-10000-25043	10201 W PICO BLVD BLDG#101	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Expired	03/05/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	Ti in the FOX technical operation center. This is the Phase 2b of the project (total of 5). EPC is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29218	18041-10000-25757	7165 W BEVERLY BLVD	90036	5	138B181   368	5525034015	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Issued	08/14/2018 12:00:00 AM	ADDRESS	34.07632	-118.34577	PC FOR PC FOR NEW LIGHTS IN THEATER FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 3154 SQ.FT. SCOPE INCCLUDES NEW LIGHTS WITH CIRCUITS. B#18016-10000-01893	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29219	16041-10000-25308	319 E 2ND ST #115A	90012	14	129A213    10	5161017034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Info Complete	07/19/2016 12:00:00 AM	ADDRESS	34.04929	-118.24098	Plan Check for Energy only. TI to an (E) coffee shop. Install new lights, receptacles, and 100A split bus panel. Newly connected load < 400 A. Total affected area: 460 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29220	18041-20000-04492	20510 W WELLS DR	91364	3	169-5A111 136	2174014026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.1573	-118.57964	Plan check for a PV1 roof-mounted PV system. System size is 9.2 kWac and consists of (40) modules, (40) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29221	19041-10000-15251	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Issued	05/03/2019 12:00:00 AM	ADDRESS	33.96577	-118.42406	Energy plan check for a gymnasium lighting replacement with a total area of 31,636 SQ FT located in a single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29222	16041-10000-17475	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	33.95667	-118.4165	*NOTE FEES ARE $0 DUE TO SENATE BILL 1222.NEW PV SYSTEM WITH 480KW AC WITH 1679 PV MODULES, 20 CENTRAL INVERTERS. SYSTEM IS NET METER TAPPING AHEAD OF MAIN. NEW PV ONLY DISTRIBUTION PANELS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29223	17041-20000-05762	11101 W VENTURA BLVD	91604	2	162B173   321	2366024004	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM			Reviewed by Supervisor	03/17/2017 12:00:00 AM	ADDRESS	34.14131	-118.37198	PLANCHECK FOR POWER ONLY . SERVICE UPGRADE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29224	13041-10001-34890	1300 S SAN PEDRO ST ste #121	90021	14	123A211    69	5132019001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	PIN	34.03251075	-118.25377188	][][plan-check only application supplemented application due to account for submittal/plan-check fee that was not initially charged during counter plan check.charges will be for illuminated energy area of 448 sq ft.  pl, 12/17/2013 ][][T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 448 SQ FT. TOTAL OF (3) UNITS WILL BE REPLACED.ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29225	17041-10001-05468	1900 N OLD RANCH ROAD	90049	11	135B133    40	4432010009	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			PC Approved	10/24/2018 12:00:00 AM	ADDRESS	34.06911	-118.50434	Expedite per applicant request. P{{{{Plan check for roof mounted PV System on SFD. System size: 24.3kW with 76 AC Modules connected to Existing 800A switch gear.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29226	14041-20000-32542	7807 N IRVINE AVE	91605	6	189B169   724	2311014026	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.2123	-118.38573	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.87kW. Ungrounded system.18 EnPhase M215-IG microinverters with 18 250W pv modules across 2 strings (10+8).Note: the solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29227	12041-10001-30459	3075 W WILSHIRE BLVD	90010	10	135B197  1198	5077009005	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Apartment			02/12/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.06197	-118.28885	THIS IS SUPPLAMENTAL TO PC# 12041-20000-30459. THIS APPLICATION IS FOR PC ONLY. APPLICANT SUBMIT A SECOND SET FOR APPROVAL. TO BE CONFIRMED WITH ORIGINAL SET AND STAMPED.New fire alarm system for 9 story highrise residential building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29228	17041-20000-37265	3641 S MOTOR AVE	90034	5	120B161   903	4314008012	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			10/26/2017 12:00:00 AM			PC Info Complete	02/13/2018 12:00:00 AM	ADDRESS	34.02382	-118.40673	New 4-story apartment building 800 240/120V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29229	18041-20001-03165	6033 W CENTURY BLVD 300	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	33.94572	-118.38954	02/15/2018 Plan check for Title 24 only. Project site is a suite on the 3rd floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 6,293 sq. ft.Note: Building application has been generated under 17016-10000-10031*****Previous Work Description*****New outlets and furniture feed locations	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29230	14041-10000-31578	6851 W IMPERIAL HWY 1440 SQ ft	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			Corrections Issued	11/13/2014 12:00:00 AM	ADDRESS	33.93207	-118.40981	TI inside warehouse offices. Total 1440 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29231	16041-20000-23194	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005021	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Expired	08/08/2018 12:00:00 AM	ADDRESS	34.15303	-118.39667	PLANCHECK FOR T24 ENERGY. CLASSROOMS FOR CAMPBELL HALL HIGH SCHOOL. 2610 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29232	14041-20002-11209	5367 N WINNETKA AVE	91364	3	171B113    69	2166006007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.16778	-118.5711	Changes from previously approved plans.  Additional of AC and DC disconnect means.Note: Permit is under the original application.  Plan check is $00.00 due to Senate Bill 1222 from 2012.*****Previous Description*****PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.25KW INTERCONNECT WITH MAIN PANEL.(1) TRANSFORMERLESS INVERTERS;  SOLAR EDGE SE6000 WITH OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29233	15041-20000-33475	20122 W VANOWEN ST 1st&2nd FL	91306	3	180B113    25	2134014024	(T)(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.19364	-118.57195	Plan check for Title 24 only for existing hotel lobby hotel by elevator. Total area: 414 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29234	16041-20000-02642	10823 W PENROSE ST	91352	7	195B177   162	2544026030	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Apartment			01/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Issued	03/25/2016 12:00:00 AM	ADDRESS	34.23246	-118.36587	Plan check for a PV2 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (56) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29235	14041-20000-17720	2465 E 16TH ST BLDG B	90021	14	118-5A219   1	5168010006	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.01994	-118.22759	TI to (E) single-story warehouse and office.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29236	15041-20000-25772	5158 W LOS GRANDES WAY	90027	4	153B193   361	5588021040	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	PIN	34.11234397	-118.30319381	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (26) modules, and (26) power optimizers. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29237	17041-10002-26143	5602 W MANCHESTER AVE	90045	11	096B173   123	4125018020	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	33.95967	-118.3791	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE REVISING LIGHTING FIXTURE SCHEDULE FOR FIXTURE B, REVISING PANEL SCHEDULE, AND REVISING LIGHTING FLOOR PLANS. NOTE: PERMIT IS PAID UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29238	17041-20001-44161	8011 N SEPULVEDA BLVD	91402	6	189B145   332	2654037024	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Apartment			05/03/2019 12:00:00 AM			PC Approved	05/03/2019 12:00:00 AM	ADDRESS	34.21607	-118.4664	5/3/19changes to an approved set of plans.  changes to service size and and distribution equipment.this is plan check only.  ((((Plan check for power and energy. Project site is a new 5-story, 32-unit apartment building over 1 level of basement parking garage. Total lighting area = 31,455 sq. ft.Note: Building application has been generated under 17010-20000-03717)))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29239	14041-20000-06440	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	pc for new service equipment for existing mall. new service only. no loads at this time. future tenants subject for plan review.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29240	18041-10000-22057	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			Reviewed by Supervisor	07/03/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full PC for power and energy for a TI in an existing restaurant inside a mall. Scope of work includes new lighting and receptacles, load>400amps. Total Sq. ft. 10530.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29241	18041-10000-21819	2601 S FIGUEROA ST Bld #5	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.02804	-118.2763	Fire plan check for an eixising fire alarm system located at the buildig #5 of the same lot of a  multi building structure. All fire alarm system located  in the lot shall interconnced through a same fire alarm system.Total 4 applications under 1 plan including building 1, 4,5 and 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29242	16041-20000-20073	990 W 190TH ST STE 200	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	33.85813	-118.29505	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PPLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 8500 IN SUITE 200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29243	17041-30000-07268	10101 N LARAMIE AVE	91311	12	204B113   475	2741010018	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.25396	-118.57342	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (23) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29244	18041-20000-21812	3057 W PICO BLVD	90006	10	129B193  1247	5080012033	(T)(Q)RAS4-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Apartment			06/12/2018 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	04/28/2023 12:00:00 AM	ADDRESS	34.04734	-118.30781	Plan check for power and energy new 6 story mixed use building 51 units appartment.  Total area: 61,588 sq ft    B#15010-10000-03721Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29245	17041-10000-19746	3376 S MOTOR AVE	90034	5	120B161   169	4314023013	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Issued	06/13/2017 12:00:00 AM	ADDRESS	34.0281	-118.40963	REPLACE  LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29246	18041-10000-05322	287 S 26TH ST	90402	11	129B137   580	4264001012	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.04691	-118.48999	PC for T24 only for removal of oudoor HID fixtures and replace with new LED fixtures. Total are 11926sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29247	11041-20000-04611	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.23541	-118.47521	Plan check power and energy for new temple.  Plans checked under NEC 2005. Original plans approved and expired #08041-20000-08250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29248	11041-10000-14612	10006 S BROADWAY	90003	8	091-5A203 121	6053022008	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Public Safety Only			07/14/2011 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	33.9453	-118.27796	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION SYSTEM FOR 16-UNITS APARTMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29249	10041-10000-25502	303 S LA BREA AVE	90036	4	135B181   192	5508001032	C2-1	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.06866	-118.34435	New CVS Store building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29250	13041-10000-25834	1615 S HAYWORTH AVE	90035	10	129B173  1191	5068019019	R2-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.04731	-118.36882	PV1 5KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: PVI-4.2-OUTD-US] [( 20) MOD: TRINA {TSM-250PA05.08}] METHANE zone with trench dams and conduit seals	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29251	19041-20000-17356	13390 N JAMIE AVE pv1	91342	7	225B149   142	2502018043	RS-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.31539	-118.45714	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM WITH ENERGY STORAGE SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 7.8KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (24) HANWHA Q CELL PV MODULES WITH POWER OPTIMIZERS, A SE7600A-US INVERTER, A LG CHEM RESU10H BATTERY, A NEW 125A PANEL, AND A SE 5000 AUTOTRANSFORMER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29252	15041-10002-08090	410 W 8TH ST	90014	14	127-5A209  75	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			Plans on Hold	10/05/2017 12:00:00 AM	ADDRESS	34.04466	-118.25638	Plan check for power and Title-24 (energy only) for lost set of plans.  Total area = 2,576 sq. ft.T.I. for new restaraunt.  Two new 225 A panels connected to existing service.  Lighting and recepticles. emergency lighting thorugh generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29253	12041-20001-08620	11425 N ALBERNI AVE	91342	7	213B177   203	2529007029	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2012 12:00:00 AM			PC Approved	07/27/2012 12:00:00 AM	ADDRESS	34.27697	-118.35572	Change from previously approved plans.  Change in Non-Fuse AC disconnect to Fuse AC disconnect and reuse existing 200A main panel.Note: Permit issued under the original application (12041-20000-08620).*****New roof mounted P.V system with microinverter.  Replace main panel and install new subpanel.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29254	18041-10000-25168	10940 W WILSHIRE BLVD #1950-#1960	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.05822	-118.4452	TENANT IMPROVEMENT IN AN EXISTING OFFICE AREA IN SUITE #'s 1950 & # 1960 ON THE 19TH FLOOR. T-24 ENERGY ONLY. BUILDING PERMIT # 18016-10000-18832	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29255	18041-10000-38218	750 S LAMAR ST OUTBOUND T-RUCK CANOP	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (I) OUTBOUND TRUCK CANOPY9 OF 10BUILDING PERMIT 13010-10000-01028	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29256	10041-20000-06425	4570 W COLORADO BLVD	90039	4	162B205   118	5593018015	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.14078	-118.27277	INSTALLING LIGHT FIXTURES IN SHIPPING AND RECEIVING AREA. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29257	12041-10000-03830	440 S SEATON ST	90013	9	127-5A215 363	5163025008	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.0421	-118.23734	PLAN CHECK NEW 600A SERVICE FOR EXISTING WAREHOUSE BUILDING. SITE IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29258	15041-20000-39720	16138 W OTSEGO ST	91436	5	171B141   310	2260020003	RA-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.16287	-118.48501	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.52KWac. (40) AC modules-SUNPOWER SPR-X20-205-BLK	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29259	14041-20000-16406	6515 W SUNSET BLVD	90028	13	147A187   104	5547017037	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.09815	-118.33161	Plan check for tittle 24 only on a 2nd floor of a 4 stories commercial building .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29260	17041-10001-02287	20256 W VIA CELLINI	91326	12	219B113    91	2701046022	RE11-1-H, RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.29285	-118.57488	EXPEDITE FEE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29261	12041-10000-27727	5865 S CAMPUS CENTER DR	90094	7	102B161  1149	4211010059		West Los Angeles				2756.01	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	33.97808	-118.40726	88 devices and one panel new fire alarm for a two story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29262	13041-10001-18169	350 S GRAND AVE B-5	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	PIN	34.05160512	-118.25169569	Change T24 lighting of approved plan. EPC is for delta 1 changes.  (((((((((TENANT IMRPOVEMENT , TITLE 24 LIGHTING, EMERGENCY LIGHTING INCLUDED. SCOPE OF WORK IS 1036 SQ FOOT.)))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29263	14041-10000-13514	7411 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	33.94176	-118.42594	PLAN CHECK FOR NEW OUTDOOR DISTRIBUTION PANEL FOR STATE APPROVED TRAILOR IN METHANE ZONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29264	14041-10000-07711	360 S ALVARADO ST #1	90057	1	133-5A205  85	5154028029	C2-1	Central	Westlake	Westlake North		2089.03	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM			PC Approved	03/21/2014 12:00:00 AM	ADDRESS	34.0613	-118.27349	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR JUICE BAR. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS. 645 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29265	10041-10001-25237	600 W 7TH ST	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			Corrections Issued	05/06/2011 12:00:00 AM	ADDRESS	34.04728	-118.25685	two new panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29266	15041-10000-24396	6718 N SYLMAR AVE	91405	2	180B149   171	2237003010	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.19273	-118.44638	NEW TWO STORY 11 UNIT APARTMENT BLDG WITH 800 AMP 120/240V SINGLE PHASE SERVICE.  PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29267	12041-20000-18457	13310 W SHERMAN WAY	91605	2	183B157    92	2328025027	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Expired	12/31/2015 12:00:00 AM	ADDRESS	34.20097	-118.42324	16' X 108' VACUUM STATION CANOPY. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29268	15041-10004-06920	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.06326	-118.20213	02/28/17Changes to an approved set of plans. All changes are clouded under delta T. Changes include removing the food kitchen area, replacing lighting fixtures, revising panels schedules, title 24, and revising floor plans.Note: Permit is paid under PCIS#15041-10000-10000-06920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29269	15041-10000-10885	8500 S VERMONT AVE BLDG G	90044	8	097-5A199 185	6032013905	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			Corrections Issued	04/18/2015 12:00:00 AM	ADDRESS	33.96105	-118.29134	"NEW DEVELOPMENT 2500 AMP SERVICE, CORE AND SHELL,  PC FOR POWER AND ENERGY. THIS IS BULDING 'G' OF 7 BUILDINGS. TITLE 24 ENERGY CALCS FOR COMMON AREAS TO BE SUBMITTED AT A LATER TIME. ENERGY FEES ARE ESTIMATED BY BUILDING LOAD CALCULATIONS. (((PROPOSED  3-STORY RETAIL AND RESTAURANT BUILDING.THIS BUILDING IS KNOWN AS BLDG ""A""  TYPE VA W/ SPRINKLER SUBSTITUTION FOR FIRE RESISTANCE RATING. )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29270	18041-20000-37892	620 W 2ND ST	90012	14	132A211    91	5151004***	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.0545	-118.25027	new distribution equipment for stage power.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29271	12041-10000-24148	700 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	TI in a retail space in terminal 7 of LAX. EPC is for T24(space# 7K)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29272	13041-10000-13940	2121 S AVENUE OF THE STARS Suite 2100	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.05554	-118.41342	PERMIT TO BE PULLED AT EPC COUNTER ONLY. PC FOR ENERGY ONLY. less than 400A connected load. hirise 21st floor.Non-structural alteration (9,431 sq. ft.) to existing office space and replace elevator lobby doors, including:  non-bearing partitions, new ceiling, millwork, and finish work.  No change of use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29273	17041-20000-40023	2945 S MOTOR AVE	90064	5	126B161   531	4318030018	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/19/2019 12:00:00 AM	ADDRESS	34.03838	-118.40791	PV1.  Install 12.6 kW roof mounted grid tied PV system.  (35) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29274	12041-10000-06041	121 W FLORENCE AVE	90003	9	102B201   794	6012013060	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	33.97486	-118.27476	New service 600 amps to replace service was under fire which is located in cover parking area.  according to applicant , sub panels are existing along with the circuits, title 24 for portion of the fire area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29275	19041-20000-49556	20790 W NORDHOFF ST Unit # 1	91311	3	198B109   218	2780001059	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	07/16/2020 12:00:00 AM		Permit Finaled	07/28/2020 12:00:00 AM	ADDRESS	34.23523	-118.58748	Plan check for power and energy, new lighting and power into the space. Total area: 2933 sq ft. New panel connected to existing 2500A Distribution. 19016-20000-38597	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29276	11041-10000-13633	5115 W WILSHIRE BLVD Ste B&C	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM			PC Approved	06/30/2011 12:00:00 AM	ADDRESS	34.06233	-118.34134	T.I.  Exisitng restaraunt on the first floor of a six story (Low Rise) building.  Remodeling of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29277	15041-10000-14255	13513 W CORNELIUS ST	91331	7	213B157   672	2523022024	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.2775	-118.42696	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.7KW, (31) Enphase Microinverter M-215 modules INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29278	16041-10001-29792	1115-1129 S BOYLE AVE PV	90023	14	123A221   272	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	34.0308	-118.22044	Expedite per applicant request{{{{{{Plan check for Feed In Tariff PV roof mounted system on commercial Building with multi address 1115, 1121,1123, and 1129 Boyle Ave. System size: 240kW with 680 modules and 3 inverters(80kW)}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29279	17041-10000-18129	959 N SEWARD ST SUITE 109-#A	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	34.08878	-118.33338	"Plan check for power and Title 24.  Change of use from commisary space to ""Spoon Fed"" Restaurant in SuiteA.  5 new subpanels and 1 new 150 kVA transformer to feed new lighting, receptacles, and HVAC equipment.  New load > 400 amps.  Total area = 4,141 sq. ft.       Building permit #17016-10000-14161"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29280	10041-10000-01621	6933 W HOLLYWOOD BLVD	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM	01/29/2010 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	ADDRESS	34.10171	-118.34135	TENANT IMPROVEMENT ON FIRST AND SECOND FLOORS OF EXISTING BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29281	14041-10000-17344	407 W 7TH ST	90731	15	015B201   797	7455006***	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Reviewed by Supervisor	07/11/2014 12:00:00 AM	ADDRESS	33.73766	-118.28583	PC FOR POWER AND ENERGY.  FIRST TIME TENANT OFFICE. TOTAL AREA 2825 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29282	13041-20002-20337	610 S ST LOUIS ST	90023	14	126A221   122	5183023003	[Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Apartment			06/11/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.03862	-118.21749	Changes to approved set.  All changes clouded and labeled with Delta 12.  Two rooms previously assigned for future use are being included in scope of work.  Lighting, recepticles, and HVAC.  Load schedules updated.*****Original scope of work*****     CHANGE OF USE FROM HISTORIC HOSPITAL TO SENIOR AFFORDABLE RESIDENTIAL UNITS, WITH 96 SENIOR AFFORDABLE UNITS, AND ONE MARKET RATE TWO BEDROOM UNIT, TOTAL OF 97 UNITS.  NEW 4000A SERVICE AND DISTRIBUTION SYSTEM.  POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29283	17041-20000-28907	23106 W BALTAR ST	91304	12	189B097   311	2014036005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/16/2017 12:00:00 AM	ADDRESS	34.21626	-118.63079	Plan check for a PV1 roof-mounted PV system. System size is 6.5 kWac and consists of (26) modules, (26) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29284	16041-10000-20428	244 E LANZIT AVE	90061	15	084B205    13	6083003009	RD2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.93024	-118.27059	PV1, rooftop solar installation on SFD, 3.8 kW AC,    (20) CS6P-265      (1) Primo 3.8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29285	15041-20000-11250	444 S FLOWER ST Suite 2550	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	Title-24 plan check only.  Total area = 1,570 sq. ft.T.I. to existing office space in commercial highrise.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29286	16041-10000-29672	1010 E JEFFERSON BLVD	90011	9	115-5A209  94	5114015045	(T)(Q)CM-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Apartment			08/22/2016 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.01202	-118.258	"FULL PC FOR POWER AND ENERGY FOR TWO NEW MULTI FAMILY AFFORDABLE HOUSING BUILDINGS. SCOPE INCLUDES A NEW 3000A 120/208V 3PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD FOR NEW AND EXISTING MULTI-BUILDING APARTMENT UNITS. NEW SERVICE IS FEEDING THREE APARTMENT BUILDINGS (TWO BUILDING ARE NEW AND ONE IS AN EXISTING BUILDING THAT IS BEING CONVERTED). TOTAL NUMBER OF UNITS INCLUDING ALL BUILDINGS IS 41 UNITS (19 DIFFERENT TYPES OF HOUSING UNITS). TOTAL AFFECTED AREA IS 38740 SQ. FT. B#16010-10000-03503""COMPLY WITH DEPARTMENT ORDER DATED 7/7/97.  PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"" refer to case #: 294805"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29287	18041-10000-01235	333 S GRAND AVE 1450	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR OFFICE TI IN A HIGH-RISE ON THE 14TH FLOOR FOR T-24 ENERGY ONLY.SCOPE INCLUDES NEW LIGHTS, RECEPTACLES AND EQUIPMENT. TOTAL AFFECTED AREA 5632 SQ.FT B# 17016-10000-33975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29288	13041-20000-22117	5124 N ALLENTOWN PL PV-1	91364	3	171B113   336	2166010012	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.16357	-118.57245	PV-1. Rooftop 6kW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29289	12041-10000-14418	2390 S WESTWOOD BLVD	90064	5	126B157   875	4320002062	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.04062	-118.42871	Plan check for energy and emergency lighting. 1651 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29290	15041-10000-38760	530 W 149TH ST	90248	15	072B201    27	6119017021	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	33.89702	-118.28433	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 15 MODULES. NONSTANDARD PLAN. PERMIT TO INCLUDE SOLAR MONITORING CIRCUIT FOR PV SYSTEM. INCLUDING RECEPTACLE ADAPTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29291	13041-20000-35346	15434 W STARE ST	91345	7	204B145   914	2660008011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.25261	-118.46875	PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.6 KW AC USING 42 MODULES 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29292	16041-10000-08616	1315 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Expired	04/25/2018 12:00:00 AM	ADDRESS	33.78944	-118.24745	PV1 INSTALL 2.04 KW DC ROOF-MOUNTED SOLAR ARRAY FOR A UNIT WITH IN A 3 UNIT APARTMENT PER SINGLE LINE. (8) MODULES: HYUNDAI HIS-M255RG(1) INVERTER: ABB PVI-2.0-OUTD-S-US -A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29293	16041-10000-24492	617 N DILLON ST 1-49	90026	13	141A203   375	5401014013	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.07899	-118.27903	LEVEL V METHANE MITIGATION SYSTEM. (1) Panel, (14) Devices to a 49 unit apartment building, with 1 subterrenean parking level and 4 floor residential.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29294	15041-10000-26135	2401 W BEVERLY BLVD	90026	13	136-5A203 160	5157010019	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.01	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	PIN	34.06858015	-118.27392721	Permit fee is $0.00 due to Senate bill 1222PV2 22.8KW 3-phase roof-mounted system with (96) Hanwha Q-cells-265 modules, (3) Solaredge SE7600-US inverters, and (96) P300 power optimizers interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29295	19041-20000-20985	4418 N VINELAND AVE	91602	4	165B173   268	2423008001	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.15103	-118.37009	Plan check for Existing Medical office. Total area: 735 sq ft. B#19016-20000-11891	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29296	17041-20000-07649	20150 W JUBILEE WAY	91326	12	213B113   403	2701087039	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.28235	-118.57339	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW .  AC STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29297	16041-10000-10878	21627 W DEVONSHIRE ST	91311	12	204B105   216	2722009005	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Expired	04/30/2018 12:00:00 AM	ADDRESS	34.2574	-118.60127	PC FOR ENERGY ONLY. T.I FOR A COMMERCIAL RETAIL STORE. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND ONE NEW PANEL. TOTAL AFFECTED AREA IS 974 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29298	16041-10000-00863	12700 W MILLENNIUM # 49	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1. SOLAR ROOF MOUNTED SYSTEM USING AC MODULES TO A TRACT HOME. 6 AC MODULES AND  AN EXTRA CIRCUIT FOR AN AC MODULE SUPERVISOR MONITOR. TOTAL SIZE: 1.5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29299	18041-10001-29423	1063 E 42ND ST	90011	9	114A209    90	5115022001	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2283.20	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.00767	-118.25697	EXPEDITE, PV2, NEW PV SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS IN A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW (72) MODULES AND OPTIMIZERS AND (2)10KW INVERTERS. TOTAL SYSTEM SIZE IS 20KWAC AND 23.4 KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29300	17041-20000-17313	11807 W LAUREL HILLS ROAD	91604	2	159B169    70	2377004020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Issued	06/01/2017 12:00:00 AM	ADDRESS	34.13566	-118.38965	$3.11 permit fees due to senate bill 1222Plan check for roof-mounted solar pv system on a SFD.13.2kW ungrounded system. (44) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29301	18041-30001-29659	16133 W VENTURA BLVD GROUND FLO	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.15675	-118.4847	02/21/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the power and lighting floor plans and have been reflected onto the Title 24 compliance forms.*****Original Scope of Work*****Plan check for T24 only on TI of (E) Bank at the ground floor. Total area: 5,215 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29302	12041-10000-30375	400 WORLD WAY TERML 4-SP 4D	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Closed	06/26/2013 12:00:00 AM	ADDRESS	33.94221	-118.40701	INSTALLATION OF ILLUMINATED SIGN AT LAX. TERMINAL 4 SPACE 4D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29303	16041-10000-43270	5375 N SAN FERNANDO ROAD WEST	90039	13	165B201    99	5593008007	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.15034	-118.27471	PC FOR TITLE 24 ONLY REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURESTOTAL AFFECTED AREA 233300 SQ.FT (OUTDOORS)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29304	12041-10000-07387	14542 W OTSEGO ST	91403	2	171A151   135	2263033030	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2012 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	06/06/2012 12:00:00 AM	ADDRESS	34.16288	-118.45034	Plan check new installation for 7.425KW roof mounted photvoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29305	16041-20001-37424	10435 N GAVIOTA AVE	91344	12	207B141   840	2668020030	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.26031	-118.48278	expedite per applicant.pv1install roof mounted pv system sized 8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29306	19041-20000-35965	20250 W SHERMAN WAY	91306	3	183B113    60	2135001046	[Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	08/18/2020 12:00:00 AM	ADDRESS	34.20085	-118.57478	PV3 PLAN CHECK FOR NEW ROOFTOP SOLAR ON EXISTING GAS STATION. SYSTEM SIZE IS 42 KW DC/40 KW AC. SCOPE OF WORK CONSISTS OF (105) PV MODULES WITH (4) 10KW INVERTERS, AND A 125A SUB PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29307	13041-20001-23530	1305 N CASIANO ROAD	90049	5	141B141    23	4368027016	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.08607	-118.47188	((EXPEDITE FEES)) PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 10KW. 31 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29308	16041-10000-26288	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.01366	-118.28294	PC FOR T24 ENERGY ONLY. NEW TRASH COMPACTORS AND LIGHITNG FOR THE AREA. LOW ADDITIONAL LOADS. CHECKING FOR LIGHTING ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29309	10041-10000-23911	11690 W SAN VICENTE BLVD	90049	11	129B145    43	4265006072	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.05353	-118.46494	Ti for a restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29310	13041-20000-23780	12200 W OLYMPIC BLVD SUITE 150	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.03195	-118.45506	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. RELOCATE AND NEW FIXTURES. TOTAL AREA 1395 SQ FT. WORK DONE IN SUITE 150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29311	14041-20000-07371	5114 S CHESLEY AVE	90043	8	111B185   579	5013006023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2014 12:00:00 AM			Not Ready to Issue	03/20/2014 12:00:00 AM	ADDRESS	33.99617	-118.33426	PV1,  TOTAL SYSTEM SIZE 3.0KWAC. NOT A TRANSFORMERLESS SYSTEM, DOES NOT REQUIRE PLAN CHECK	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29312	19041-10000-01324	3651 S TROUSDALE PKWY ZHS-Rm #319	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM			PC Info Complete	01/14/2019 12:00:00 AM	ADDRESS	34.01922	-118.28617	PLAN CHECK FOR TITLE 24 ONLY FOR - TI OF (E) LABORATORY at USC campus Zumberg Hall of Science #319 - TOTAL AFFECTED AREA = 686 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29313	18041-10000-13109	10815 W HESBY ST	91601	2	171B173  1034	2419006030	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1255.01	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.16184	-118.36649	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON APARTMENT BUILDING - SYSTEM SIZE = 11KVA AC CONSISTING OF (2) CENTRAL INVERTERS(SE5000H-US), SE6000H-US)and  WITH 47 PANELS USING POWER OPTIMIZERS(P370).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29314	12041-20000-15825	12755 W VAN NUYS BLVD	91331	7	210B161    41	2533019032	[Q]C2-1VL-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.27575	-118.41171	T-24 lighting plan check for mezanine floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29315	19041-20000-47402	13148 W VICTORY BLVD 1-12	91401	2	180B157  1157	2331005003	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM			Reviewed by Supervisor	01/23/2020 12:00:00 AM	ADDRESS	34.18643	-118.41983	FULL PC FOR A NEW 800A SERVICE THAT FEEDS AN 800 SWITCHBOARD WHICH SUBFEEDS TWELVE SUBPANELS. THE 800A SWITCHBOARD ALSO FEEDS A 200A HOUSE PANEL THAT FEEDS ALL ASSOCIATED HOUSE LOADS AND A 30HP ELEVATOR. TOTAL AFFECTED AREA IS 15,756 SQFT. PER BUILDING((NEW  TYPE III-B 5-STORY APT WITH BASEMENT GARAGE. FULLY SPRINKLERER, NFPA-13.B#18010-20000-01770))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29316	19041-10000-34001	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	07/21/2020 12:00:00 AM		Permit Finaled	07/08/2021 12:00:00 AM	ADDRESS	33.96577	-118.42406	24,300 SF 4-STORY NEW CONSTRUCTION HIGHER EDUCATION WITH PRIMARLY CLASSROOM PROGRAM STRUCTURAL + CALS CIVIL METHAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29317	12041-20001-09896	5080 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM			PC Info Complete	02/19/2013 12:00:00 AM	ADDRESS	34.02028	-118.35491	"Changes to approved set of plans. Changes to electrical room, addition of ""temporary power"" on 1-line (see E6.2). List of changes has been included and all changes have been clouded on plans. Relocation of ""Hand dryer"" from LN-28,30 to LNA-9,11. 4 new circuits (HA-32, LN-28,30,32).Remodel. Ralph's store. Plan check for power and energy. 59333 SF condtioned and 20575 exterior SF. Single story commercial grocery store building."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29318	17041-10000-12225	3630 W WATT WAY # 106	90089	9	118-5A201  14	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.02062	-118.28738	PC for T24 only in classrom. Changing from flourecent strip ligths to new led downlights. Total affected area is 1288 sqft. buidling# 17016-10000-09345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29319	16041-10000-37054	12985 W FOOTHILL BLVD	91342	7	219B161   236	2514003049	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.29579	-118.41734	PC for title 24. Energy only. Scope includes replacment of new LED fixturesTotal affected area of 44,050 sq.ft. (33550 outdoors 10500 indoors)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29320	19041-10000-51406	1701 N AVENUE 56	90042	14	157-5A227 208	5485002007	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.12582	-118.19659	Plan check for a PV1 3.19KW roof mounted system. Scope includes (1) inverter, (11) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29321	15041-20001-39066	15924 W ACRE ST	91343	12	195B141   589	2672031017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	34.23005	-118.47946	This is PC only, rooftom silar installation 7.6kW AC system.(28) SW-285 Mono(1) SE10000-USPermit under 15041-90000-39066Standard plan is used.((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29322	14041-10000-03282	1950 E WASHINGTON BLVD	90058	14	118-5A215  29	5167005015	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	PIN	34.01879134	-118.23748008	plan check for power and energy. INSTALLING CNG GAS FUELING FACILITY WITH VENDOR FABRICATED EQUIPMENT COMPRESSOR, DRYER, STORAGE VESSELS, AND ASSOCIATED INTERCONNECTING PIPING ALONG WITH FAST FILL DISPENDING EQUIPMENT. (2) 5HP FANS INSIDE EACH COMPRESSOR (3 TOTAL COMPRESSORS; COMPRESS 'A', 'B', 'C' EACH @ 250HP  ). OUTDOOR LIGHTING FOR SPECIFIC APPLICATION ALSO IN SCOPE OF WORK. CLASS 1, DIV 1 AND CLASS 1, DIV 2 SPACE.NOTE: AREA CLASSIFICATION ON SHEET E-2.0	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29323	15041-10000-00676	610 S MAIN ST	90014	14	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			01/09/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Closed	06/28/2017 12:00:00 AM	ADDRESS	34.04479	-118.25017	HIGH RISE BUILDING; replace with 2 new fire alarm control panels and adding/replace total of  581 devices to the fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29324	16041-20000-45107	11961 W DOROTHY ST	90049	11	129B145   551	4265020012	(Q)RD2-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			12/23/2016 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.04956	-118.47003	NEW 4 UNITS MULTI FAMILY APARTMENT BUILDING, FOUR STORIES OVER SUBTERRANEAN PARKING.  NEW 120/240V 3PH-4W 600A SERVICE.  PLAN CHECK FOR POWER AND ENERGY.  Building permit filed under 16010-10000-05386	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29325	12041-20000-05273	21271 W BURBANK BLVD	91367	3	174B105    74	2149019002	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Approved	03/08/2012 12:00:00 AM	ADDRESS	34.17497	-118.59473	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29326	15041-10001-20223	17700 W ROSCOE BLVD	91325	12	192B129   324	2101001001	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	34.22071	-118.51893	Changes made to approved set.  Plans modified to indicate circuit supplying unit equipment are connected ahead of local lighting controls in accordance with Article 700.  Delta-C changes only.  (((Full plan check for a new McDonalds restaurant with drive through  service.  Scope includes a new service of 1000-Amp ,120/208V, 3-phase 4-wire.  T-24 covers in/outdoor with a toatal area of 24,129-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29327	17041-10000-15358	637 S MAPLE AVE A	90014	14	127-5A211 167	5148022011	C2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.04322	-118.24879	PC FOR TI TO OFFICE SPACE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29328	17041-10000-22607	10250 W SANTA MONICA BLVD # 2890	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan check for First tenant- Francesca's Ste. 2890	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29329	19041-10000-19480	17641 W VENTURA BLVD	91316	5	171B129   334	2257008026	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.1624	-118.51764	T-24 PLANCHECK FOR A TI OF AN EXISTING RESTAURANT. REMODEL INTERIOR LIGHTING AND RECEPTACLES IN RESTROOM AND DINING AREA ONLY. TOTAL AFFECTED AREA IS 2082 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29330	12041-10000-22321	5620 N MURIETTA AVE	91401	2	174B153   717	2246031014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2012 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.17286	-118.43874	SFD ROOF-MOUNTED  2.16KW PHOTOVOLTAIC SYSTEM USING MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29331	18041-10000-35859	9801 S ALAMEDA ST	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	05/04/2020 12:00:00 AM	ADDRESS	33.94794	-118.22929	FULL PLAN CHECK FOR POWER AND ENERGY - FIRST TENANT IMPROVEMENT FOR RETAIL APPAREL STORE. ALL NEW WORK SHALL CONSIST OF INTERIOR PARTITIONS, MILLWORK, ELECTRICAL WORK, MECHANICAL AND PLUMBING, AND FLOORING MODIFICATIONS. - TOTAL AFFECTED AREA = 13000 (TAYLOR METHOD) WITH APPROX 450A OF CONNECTED LOAD TO EXISTING 800A 120/208V DISTRIBUTION BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29332	10041-10001-22348	8378 W MELROSE AVE	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.08341	-118.37285	"TI in a retail. New service and panels. EPC for power and energy. CORE & SHELL ONLY.COMPLETE PLAN CHECK WILL BE REQUIRED FOR EACH TENANT.  <<<<<<Methaen Buffer Zone Level 1 with less than 2"">>>>>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29333	14041-10000-27196	1000 S SAN PEDRO ST A	90021	14	124-5A211 149	5132011022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.03569	-118.25164	"Energy plan check for a retail T.I  unit""A"" in a commercial building. total remodeling area covers 2351 SQ feet."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29334	11041-10000-20259	131 S CENTRAL AVE	90012	14	129A215   378	5161017***	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	09/22/2011 12:00:00 AM	ADDRESS	34.04846	-118.2395	title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29335	14041-20000-27359	320 S HAMPTON DR	90291	11	111B141   717	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	33.99612	-118.47637	TI TO AN EXISTING COMMERCIAL ONE STORY BUILDING.  ADDING PANELS, MOTORS, CIRCUITS TO THE EXISTING SERVICE.PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29336	17041-10003-20044	10011 W CHEVIOT DR	90064	5	123B165   225	4316015006	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	02/09/2019 12:00:00 AM	ADDRESS	34.03578	-118.40305	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES RELOCATION OF POWER WALL TO THE GARAGE (INDOOR) AND MOVING THE PV CIRCUIT TO THE HOUSE PANEL.  Installation of new energy storage system.  New 200 amp load center and Tesla AC Powerwall 5.8 kVA 13 kWH battery.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29337	16041-10001-22112	535 W EL SEGUNDO BLVD	90248	15	081B201   252	6132002022	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Apartment			07/24/2017 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	33.91658	-118.284	Supplemental PC for addition of 100A breaker for future PV 28KW system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29338	16041-10000-18148	10960 W WILSHIRE BLVD 8TH FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	PC FOR ENERGY,  new non-rated corridor with new finishes, ceiling, lighting and doors. All work within 8th floor. HIGHRISE.  TOTAL AREA 1044 SQ FT.B # 16016-30000-10652	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29339	16041-10001-37951	6929 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Approved	05/24/2018 12:00:00 AM	ADDRESS	34.19659	-118.49256	"PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES CHANGES TO BREAKER SIZE ON ""MSA"" FROM 200A TO 400ATHIS IS PLAN CHECK ONLY. PERMIT UNDER MASTER APPLICATION."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29340	16041-10001-18613	1530 S OCEAN FRONT WALK	90291	11	106-5A143  65	4226001903	OS-1XL-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	09/12/2016 12:00:00 AM	ADDRESS	33.98684	-118.47372	Amandment to an approved set of plan, upgrading service and distribution equipment from 1000A to 1200A. Plan check only. Permit should be pulled under the original application.cam lock outlet changed to 1000A. PC only no permit under this application{{{AEXISTING OCEAN FRONT. NEW SERVICE FOR STREET VENDORS AND LANDSCAPE LIGHITNG. NEW PANEL FOR FUTURE USE. NO TITLE T24 - EXEMPT. PC FOR POWER ONLY. 1000A SERVICE}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29341	15041-20000-30913	21700 W OXNARD ST STE 500	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.17901	-118.60179	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HIGH RISE OFFICE. 3730 SQFT, EMERGENCY LIGHTING. SUITE 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29342	17041-10000-16616	8700 W BEVERLY BLVD Davis Bldg-G-140	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Closed	04/27/2018 12:00:00 AM	ADDRESS	34.07666	-118.3805	Plan check for power and energy  Medical Facility Cedars Sinai installation of MRI Machine new lighting and receptacles. Total area: 843 sq ft. B#17016-30000-13125	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29343	14041-10000-24971	7331 N HINDS AVE	91605	2	186B169   801	2317018042	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.20384	-118.39119	Title 24 plan check only. Remove HID light fixtures and replace with new LED fixtures. 3430 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29344	16041-10001-27954	19681 S PACIFIC GATEWAY DR	90502	15	057B197    35	7351034056	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.85319	-118.29547	10/18/16Changes to an approved set of plans. All changes are made under delta 2. Installed combiner panel for service C interconnection. Change of point of interconnection to circuit breaker with ground fault relay.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29345	15041-10000-43453	18569 W DEVONSHIRE ST	91326	12	204B121    71	2728028023	C2-1VL, QC2-1VL, QP-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	PIN	34.25808925	-118.53932955	T-24, TI TO AN OFFICE SPACE, SCOPE OF WORK INCLUDES THE ADDITION OF CUBICLES LESS THAN 5FT 9INCHES. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACELS. TOTAL SQ. FT. 1671	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29346	16041-10000-44567	2525 W FLORENCE AVE	90043	8	102B189  1250	4008022001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	33.97474	-118.32143	PC FOR ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 10890 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29347	15041-10000-09288	12105 W WATERFRONT DR	90094	11	105B161  1199	4211010048	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	33.98095	-118.40764	Plan check for a methane detecting system ; Scope includes (38) sensors, (6) fire alarm devices, and (1) control panel located at  a 5-story new commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29348	18041-20000-07365	7211 W MULHOLLAND DR	90068	4	156A181   637	5549006019	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	PIN	34.12024814	-118.34716955	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (17) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29349	18041-10001-19771	1302 S LA BREA AVE	90019	10	129B181   842	5070001018	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM			No Progress	07/25/2019 12:00:00 AM	ADDRESS	34.04983	-118.34395	SUPPLEMENT TO AN APPROVED PLANS, CHANGE UNDER DELTA-8,9, and ESK. MAJOR CHANGE INCLUDE REMOVING 400A FEEDER FOR THE GENERATOR. NARRATIVE IS INCLUDED WITH THE PLANS **********ORIGINAL SCOPE: NEW TWO  STORY RETAIL (SPROUTS) STORE********************BUILDING EXISTING SERVICE APPROVED UNDER CORE AND SHELL.********************PLAN CHECK FOR POWER AND ENERGY.********************ORIGINAL PLAN CHECKER MEHDI ZANDI**********	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29350	11041-10001-24713	818 W 7TH ST Ste 510	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM			PC Approved	12/19/2011 12:00:00 AM	ADDRESS	34.04895	-118.25943	Changes from previously approved plans.  Partial of open office area change to conference room.  All changes are clouded on the plans.  Plan check for energy only.  *****T.I. to an existing office building on the 5th floor.  PLAN CHECK ONLY for Energy, with Emergency lighting.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29351	14041-20000-09785	15800 W ROSCOE BLVD	91406	6	192B141   492	2673021041	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	34.2212	-118.47638	pc for t24 energy only. new lighting in storage space. permit already issued under permit# 14041-20000-08240	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29352	18041-10000-15476	2465 E 23RD ST	90058	14	118-5A217 218	5168013017	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.01744	-118.22817	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29353	17041-20000-04158	15000 N ANAYA DR PED	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.23827	-118.45904	100A 120/240V 1ph-3w service for residential tract site lighting/irrigation controller.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29354	15041-20000-08518	6220 N TOPANGA CANYON BLVD 1460	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	Plan check for power and Title-24 (energy).  Total area = 2,863 sq. ft.T.I. to retail space.  First time tenant.  One new 150 kVA transformer connected to a 400 A panel and a 225 A panel.  New lighting and recepticles. Katsuya Restaurant. Building E. Meter/Feeder #4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29355	15041-20000-14502	12746 W JEFFERSON BLVD Bldg 2-Ste 2110	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check for power and energy. Project scope is a first time tenant. Work included the installation of (1) 250-amp panel, (1) 125-amp panel, associated loads, and (1) 75-kVA transformer. Total lighting area = 1,427 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29356	17041-10000-27835	414 E COMMERCIAL ST	90012	14	130-5A215  34	5173001017	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Issued	08/08/2017 12:00:00 AM	ADDRESS	34.0533	-118.23724	REMOVE METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY. TOTAL SQUARE FT 3550.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29357	10041-20000-02484	6704 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	34.11738	-118.33854	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29358	18041-20001-08278	4150 N HAYVENHURST AVE	91436	5	165B137   429	2291013014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM			PC in Progress	03/10/2018 12:00:00 AM	ADDRESS	34.14634	-118.49729	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 13.8 kWac and consists of (43) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29359	11041-20000-15734	6530 N LANKERSHIM BLVD #C, D, E	91606	2	180B169   731	2335009022	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.18952	-118.38758	3 TENANT SPACES (C, D, E) CONVERETD TO ONE TENANT SPACEPLAN CHK IS FOR TITLE 24 ENERGY AND EMERGENCY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29360	18041-10002-09270	3836 N HAYVENHURST DR	91436	5	162B141   231	2286021041	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.14043	-118.48528	expedite per applicant request. PC for 40kW(ac) PV ground mounted system for SFD. Installing 140 modules [44.8kW(DC)], 140 optimizers, 225 load center and four 10kW central inverters connecting system to line side of main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29361	19041-10001-31918	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	34.18421	-118.60617	PC for additional devices for the main fire alarm system (corn and sheell)  pulled under 19041-10000-31918, total new amount of devices 51.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29362	16041-10000-44949	3549 1/2 W CASITAS AVE LOT 11	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Issued	06/14/2018 12:00:00 AM	ADDRESS	34.1209	-118.25689	Plan check for Power 11 buildings SFD live work  3 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 11 of 11Note: Master Application Lot 11 type A1,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29363	17041-10000-21248	755 S COCHRAN AVE	90036	4	132B181   197	5089003032	R3-1-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.06081	-118.34781	T24 ONLY - REPLACEMENT OF EXISTING LIGHT FIXTURES WITH (11) LED FIXTURES.  TOTAL AFFECTED AREA =  5200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29364	16041-20000-02630	10705 W PENROSE ST Unit A	91352	7	195B177   108	2544027007	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Issued	04/04/2016 12:00:00 AM	ADDRESS	34.23241	-118.36447	Plan check for a PV2 roof-mounted PV system. System size is 2.2 kWac and consists of (10) modules, (10) micro-inverters, and (1) load center. Multi-tenant building (3 tenants) will have a total of (3) PV systems interconnecting to it.Note: Solar clearance shall apply to all (3) tenants.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29365	19041-10000-07840	725 S FIGUEROA ST #3275	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	TENANT IMPROVEMENT TO THE (E) OFFICE SPACE. CONVERT OPEN SPACES TO ENCLOSED OFFICESPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29366	17041-10000-15645	929 W JEFFERSON BLVD Suite 1620	90007	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	Plan check for power and Title 24.  First time tenant improvement for ice cream shop.  One new 225 amp subpanel connected to existing distribution system.  Total area = 908 sq. ft.       Building permit #17016-10000-12243	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29367	19041-20000-41387	11825 W TERRA VISTA WAY #135	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29368	12041-10001-04548	719 S BROADWAY	90014	14	127-5A209  53	5144014037	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM			PC Approved	02/19/2013 12:00:00 AM	ADDRESS	34.04483	-118.25393	Modifications to approved set of plans. Basement lights for unisex fitting room, processing office, stairways and escalators. *************************************************12041-10000-04548 Description: T.I. on the existing Woolworth Building.  Interior upgrade of Basement and Ground levels for New retail space with loading dock and storefront modification.  New panels, circuits, loads, xfrmr, and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29369	14041-10000-00531	900 S CRENSHAW BLVD	90019	4	132B189   914	5092003022	CR-1VL	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			02/06/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.05612	-118.32202	FULL PLAN CHECK FOR POWER AND ENERGY. NEW 1600A UNDERGROUND, 120/208V,3PH,4WIRE SERVICE. NONE METHANE ZONE PER ZIMAS. SCOPE OF WORK IS FOR CONSTRUCTION OF NEW APARTMENT WITH 32- 1- BEDROOM AND STUDIO UNIT APARTMENT WITH A  RECREATIONAL ROOM, AND OFFICES ON THE FIRST FLOOR.BUILDING PERMIT SUBMITTED IN 2013 UNDER: 13010-10000-02177. THIS PLAN WILL BE SUBJECTED TO THE 2008 NEC , 2010 CEC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29370	13041-20000-13318	13601 W VENTURA BLVD	91423	4	165B157   643	2360006032	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	PIN	34.14808189	-118.42975517	Plan check for energy and emergency lighting. Floyd's 99 Barbershop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29371	18041-20000-40895	13937 N TUCKER AVE	91342	7	228B161    63	2582026035	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.32489	-118.40904	Plan check for PV roof mounted system, system size:3.96KW DC, 3.78KW AC,   with 12 PV Modules and 12 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29372	14041-20000-21348	6201 W HOLLYWOOD BLVD 114	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	Energy plan check for TI from retail to an exercise Gym, suit number 114 from a commercial building. total area is 3714 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29373	17041-10000-33519	6101 S AVALON BLVD	90003	9	105B205   610	6006023031	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	33.98412	-118.26544	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29374	19041-20001-03933	2450 N SUMMITRIDGE DR	90210	4	153B157    36	4386014046	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.11852	-118.42251	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 448.88 kWdc/41.1 kWac-CEC and consists of (1) 43.2 kWac rated inverter and (136) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29375	16041-10000-25170	776 E 46TH ST	90011	9	112-5A207 262	5108006012	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.00145	-118.26208	PV1 SYSTEM WITH 5KW AC CENTRAL INVERTER. USING 14 MODULES IN TOTAL. SYSTEM IS ROOF TOP MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29376	14041-10000-03691	1015 S CROCKER ST #505	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	replacing HID LUMINAIRE WITH FLUORESCENT LUMINAIREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29377	12041-10000-11793	12381 N NUGENT DR	91344	12	219B129   508	2608017001	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.29565	-118.51252	Plan check for 9.24KW roof mounted photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29378	13041-20001-27892	1500 E ANAHEIM ST	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	33.78074	-118.24357	EXPEDITE FEES ONLY.           <<<30kw rooftoop PV system for a new commercial building.  System is Ungrounded.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29379	11041-10000-27164	21816 W LANARK ST	91304	3	189B105    74	2110002900	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.21744	-118.60384	T-24 ENERGY CALCS FOR OUTDOOR LIGHTING IN A SOCCER FIELD.  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29380	10041-20000-03979	5400 N BALBOA BLVD s.311	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM			PC Approved	03/05/2010 12:00:00 AM	PIN	34.16914714	-118.50029545	s.311  medical office t.i.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29381	11041-10000-15197	622 W 30TH ST	90007	8	121-5A203 215	5123010002	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			07/20/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	08/05/2011 12:00:00 AM	ADDRESS	34.02533	-118.27891	152 NEW CIRCUITS AND 19 NEW SUB-PANELS FOR AN EXISTING USC DORMITORY APARTMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29382	14041-10000-34493	6930 N HAYVENHURST AVE	91406	6	183B137   327	2224019011	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.1964	-118.49221	T24, REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 12764 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29383	14041-10000-11711	14837 W SATICOY ST	91405	6	186B149   179	2210033008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.20859	-118.45667	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29384	19041-10000-07593	22304 W MOBILE ST	91303	3	180B101   636	2139025017	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.1882	-118.61203	PV1.PLAN CHECK FOR A NEW ROOFTOP SOLAR SYSTEM WITH 2 LG CHEM RESU10H 9.8KWH BATTRIES. PV SYSTEM CONSIST OF 27 MODULES (PANASONIC VBHN330SA16), 27 OPTIMIZERS (SE P400) AND 1 CENTRAL INVERTER (SE7600A-US). SYSTEM SIZE IS 8.91KWdc AND 7.6KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29385	09041-20004-24366	3327 E SABINA ST Bldg A	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			08/09/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 3 & Delta 4. Revision to approved plans for New Apartment Complex w/ multiple buildings (Bldg A) 1of 2 Building. Includes additional ckts added for sign lighting and handicap lift.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29386	19041-20000-09127	10575 W SELKIRK LANE	90077	5	153A151   813	4380002014	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	05/05/2022 12:00:00 AM	ADDRESS	34.11162	-118.44953	addition to an existing sfd with a service upgrade to 600 amp.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29387	16041-10000-03668	10100 W SANTA MONICA BLVD 9TH FLOOR	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24, TI IN A (E) OFFICE SPACE IN A HIGHRISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES WITH IN THE OFFICE. TOTAL SQ. FT. 5130.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29388	14041-10000-04153	12953 W MAGNOLIA BLVD	91423	4	171B161   511	2345017008	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			Reviewed by Supervisor	03/06/2014 12:00:00 AM	ADDRESS	34.16502	-118.4155	PV1, Install 8.25 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 6000A-US-ZB-U. (33) Modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29389	13041-10000-33066	4901 S MARIONWOOD DR	90230	11	108B161   250	4218002907	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	33.99325	-118.41076	TITLE 24 PART 6 ENERGY PLAN CHECK; SCOPE OF WORK IS < 400A ; TENANT IMPROVEMENT IS FOR NEW LIGHTING IN A 5,243 SQ FT. e-permit TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29390	15041-10000-03576	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.07196	-118.24719	Title 24 plan check only.  Total area = 328 sq. ft.Renovation of existing dodger stadium level 7 concessions.  Installation of 4 new lights (outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29391	10041-10000-01026	1 W WORLD WAY WEST TBIT BSMT	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	PIN	33.94461393	-118.39808495	REPLACING 3 EA 100HP CHILLERS AND 2 EA HOT WATER PUMPS. UNDER NORMAL OPERATION, ONLY 2 EA OF THE CHILLERS WILL BE ON LINE. THE THIRD CHILLER IS A REPLACEMNT ( INTERLOCK PROVIDED) FOR THE LOST OF ANY ONE OF THE 2 EA CHILLERS ON LINE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29392	18041-20000-22051	501 W 190TH ST	90248	15	060B201   140	7339008035	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	33.86259	-118.28248	Plan check for power only EV Chargers installed in parking lot in existing facility. Total newly connected load exceed 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29393	13041-10001-30923	282 S THORNE ST	90042	14	153A233   370	5492039021	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.03	Electrical	Electrical	Apartment			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/19/2013 12:00:00 AM	ADDRESS	34.11225	-118.18085	Expedited RSES plan check per applicant request. (((PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 10 modules: HANWHA # HSL60P6-PB-4-250TW.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29394	14041-20000-04888	15960 W BLYTHE ST	91406	6	189B141   107	2206007020	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Issued	06/25/2014 12:00:00 AM	ADDRESS	34.21468	-118.48117	commercial new service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29395	18041-10000-10641	6922 W HOLLYWOOD BLVD 4TH FLR	90028	13	147B181   198	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	PC FOR OFFICE TI FOR TITLE 24 ENERGY ONLY IN A HIGH RISE. INSTALLING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1337 SQ.FT. PERMIT FEES PARTLY PAID UNDER 18041-90000-09577 (FOR 4 CIRCUITS).B# 17016-10000-37782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29396	14041-10000-11744	1616 N LA BREA AVE	90028	13	147B181   377	5548012046	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			05/02/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.1002	-118.34456	[[5/2/2014- PLANS EXPIRED IN 2010, USE 2008 CODE CYCLE FOR PLAN CHECK. EXPIRED PLAN CHECK ON APPL#:09041-10000-17341]] New 56-unit, 4 sotry mixed-use building.  Power and energy.  A variance has been filed to separate the fire alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29397	17041-10000-28236	369 N SUMAC LANE	90402	11	123B129   446	4410024028	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.03339	-118.51374	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PV1,  NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.25KWdc / 3.0KWac. ALSO ADDING ONE  5.8KW, 13.5 KWH ENERGY STORAGE SYSTEM.(TESLA POWER WALL).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29398	18041-10000-09398	1318 W MARYLAND ST	90017	1	132A207   186	5152002009	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.05595	-118.26163	PC FOR NEW FA  IN 3 STORY APT BUILDING. TOTAL DEVICE COUNT 85 DEVICES AND 2 PANEL (1 POWER SUPPLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29399	10041-10000-22233	6801 W HOLLYWOOD BLVD #Bb2-228	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	03/04/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	Tenant improvement in THE SALES AREA OF an existing jewelry storeplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29400	18041-10000-48427	14761 W BESSEMER ST	91411	6	177A149    50	2241024003	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Issued	12/21/2018 12:00:00 AM	ADDRESS	34.18091	-118.45519	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29401	16041-30000-03167	11975 W TEXAS AVE 1-9	90025	11	126B145   186	4263005050	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.04413	-118.46449	Maintenance replacement of fire alarm system in existing 9 unit apartment building.  Replace FACP + 48 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29402	16041-10001-08550	200 N SPRING ST 19TH FL &-21ST FL	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.05405	-118.24317	06/16/16Changes to an approved set of plans. Adding/replacing new lighting fixtures, new controls and. adding new receptacles for the office space. Application is for the 19th and 21 floors.Note: The master application is under PCIS#16041-10000-08550  (((((TENANT IMPROVEMENT ON 19TH AND 21ST FLOORS OF LA CITY HALLTITLE 24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29403	12041-10001-30354	8366 W 3RD ST	90048	5	138B173   844	5511031023	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/02/2013 12:00:00 AM	ADDRESS	34.07268	-118.37231	"PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT FOR ""JUICE SERVED HERE'. ***SUPPLEMENTAL TO 12041-10000-30354.* NEW APPLICATION CHANGES TO APPROVE SET OF PLANS. ONLY CHANGES ARE TO SINGLE LINE DIAGRAM AND INSTALLED EQUIPMENT. NO TITLE 24 CHANGES. PLAN CHECK FOR TITLE 24 IS SAME AS APPROVED PLANS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29404	17041-30000-46492	9301 N TAMPA AVE Space 27	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,835 sq. ft.Note: Building application has been generated under 17016-40000-37914	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29405	13041-20000-14071	19602 W CITRUS RIDGE DR	91356	3	171B117   572	2175040004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.16219	-118.56065	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 13.230 KWDC. 54 MODULES 2 INVERTERS WITH 1 SUB PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29406	17041-10000-24505	4801 W EXPOSITION BLVD	90016	10	120B181   914	5046011041	CM-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.02444	-118.34857	T-24, PC FOR ENERGY ONLY. REPLACING EXISTING FIXTURES WITH LED FIXTURES FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 42150 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29407	13041-10000-35723	1186-1188 E 43RD PL # 1186	90011	9	114A209   376	5115034014	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.00466	-118.25446	PV1, Install 2.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (10) modules Trina Solar TSM-250PA05.18.One of two systems on the same building from range 1186 to 1188 43rd pl.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29408	14041-10000-22813	115 N AVENUE 53	90042	1	150A227    15	5468020015	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.10734	-118.19831	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Emergency lighting existing to remain.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29409	11041-20000-12339	13164 W BURBANK BLVD GUARD-HOUSE	91401	5	174B157   656	2345005022	C2-1, R1-1, R3-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.17196	-118.4201	PLAN CHECK T24 ENERGY FOR NEW GUARD HOUSE AND STORAGE FOR GUARD HOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29410	11041-10000-16965	520 S VIRGIL AVE #303	90020	4	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	09/12/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.06457	-118.28687	TI FOR MEDICAL.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29411	18041-20001-14343	625 N BUNKER HILL AVE	90012	1	135A213   405	5407004042	R4-1	Central	Central City North	Historic Cultural	YES	2071.01	Electrical	Electrical	Apartment			12/14/2018 12:00:00 AM			Not Ready to Issue	02/20/2019 12:00:00 AM	ADDRESS	34.06202	-118.24445	12/14/2018 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is parking garage and common area lighting. Total lighting area = 20,821 sq. ft.*****Original Work Description*****REMOVE AND REPLACE LIGHT FIXTURES-DEVICES, SMOKE DETECTORS (32) UNITS COMMON AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29412	15041-20000-25803	13720 N BRADLEY AVE	91342	7	228B141   413	2603017002	RE11-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.31747	-118.47858	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consist of (1) inverter, (28) modules, and (2) combiner boxes. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29413	17041-10001-37840	6157 N RHODES AVE	91606	2	177B165   338	2333011020	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.18272	-118.40315	EXPEDITE APPLICANT REQUEST, PLAN CHECK ONLYPLAN CHECK FOR ROOF MOUNTED PV ON SINGLE FAMILY. SYSTEM SIZE 9.6KWAC/12.0KWDCSCOPE INCLUDES 40 MODULES WITH MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29414	17041-10000-44316	7680 W MULHOLLAND DR	90046	4	156B177    30	5570011007	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.12805	-118.363	Plan check for a battery back up system 5.0kW in Single Family Dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29415	16041-20000-39088	1840 S CENTURY PARK EAST Suite 450	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	Plan check for Title 24 only. Project site is a suite within an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 2,737 sq. ft.Note: Building application has been created under 16016-10000-23171	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29416	19041-30000-14217	1031 S BROADWAY 1st Floor	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM			PC Info Complete	04/18/2019 12:00:00 AM	ADDRESS	34.04041	-118.2583	Plan check for Title 24 only. Project site is a tenant space on the 1st floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,868 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29417	13041-10001-33035	6208 N DENNY AVE	91606	2	177B177   287	2414011013	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.18324	-118.36471	Expedited RSES plan chck per applicant request.[][][][PV1, Install 6.5 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (26) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29418	17041-10000-26317	6904 N TUJUNGA AVE	91605	2	183B173   176	2319005035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.19577	-118.37887	PC for T24 only for new lighting and recetpacles for storage/office room TI. Installing new lights and circuits. Total of 15516 sqft. Building #16016-10000-23433.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29419	16041-10000-03839	1861 N TALMADGE ST	90027	4	150B201  1156	5591023013	R2-1XL	Central	Hollywood	Los Feliz		1952.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	04/16/2016 12:00:00 AM	ADDRESS	34.1049	-118.28324	PV1, ROOF MOUNTED SOLAR SYSTEM USING MICRO INVERTERS. (14) MODLUES AND (14) MICROINVERTERS. TOTAL SIZE 3.5 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29420	17041-10000-17548	20500 W PRAIRIE ST	91311	12	198B109   111	2748041013	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.23904	-118.58074	T24 ONLY. REPALCE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING: 60300 SQ FT. (OUTDOOR/INDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29421	18041-10000-27989	1320 E NEWTON ST	90021	14	121-5A213 102	5130011033	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.02746	-118.24664	CHANGE OF USE FROM PARKING TO OFFICE & WAREHOUSE. INSTALL NEW SERVICE, 250KW GENERATOR, PANELS, & LOADS. PLAN CHECK FOR POWER & ENERGY. 16,500SQR FT.BLDG PERMIT: 18016-10000-23726	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29422	18041-10000-49145	2117 N AMELIA AVE	90731	15	024B193    82	7442009004	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	33.76397	-118.30269	PLAN CHECK FOR 5.67 KW ROOFMOUNTED PV SYSTEM CONSISTE OF (18) MODULES  AND (1) TESLA  ENERGY STORAGE SYSTEM. SCOPE INCLUDES (1) DELTA (SOLIVIA 5.2) SOLAR INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29423	14041-10000-11700	658 E VENICE BLVD	90291	11	108B145  1545	4237002006	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM			Verifications in Progress	10/10/2014 12:00:00 AM	ADDRESS	33.98963	-118.46093	PV2 3PHASE SYSTEM. TOTAL SYSTEM SIZE 144KWAC. 686 MODULES AND 3 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29424	17041-20000-08891	2942 S BEVERWIL DR	90034	5	123B165   148	4311001034	R1-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.03657	-118.39806	Plan check for a PV1 roof-mounted PV system. System size is 7.2 kWac and consists of (21) AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29425	19041-10000-10781	1414 N CATALINA ST	90027	13	147B197   848	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			Reviewed by Supervisor	04/29/2019 12:00:00 AM	ADDRESS	34.09716	-118.29486	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 4 FA PANELS, 115 FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29426	19041-20000-06898	959 N SEWARD ST 311	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	T24 PLAN CHECK TO STE311 OF EXISTING COMMERCIAL BUILDING. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1,513SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29427	13041-10005-04211	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			10/18/2016 12:00:00 AM			PC Approved	10/18/2016 12:00:00 AM	ADDRESS	34.06209	-118.34912	CHECKING FOR CHNGES TO APPROVED SET OF PLANS. CHECKING DELTA 8 REVISIONS. CHANGED NUMBER OF NUNITS PER METERING SECTIONS. CHANGES 3 IN TOTAL. THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29428	19041-20000-50578	8510 N ADIR DR	91304	12	192B097   626	2004026027	(Q)RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.22486	-118.6232	PV1. INSTALL 9.28 KW DC PV SYSTEM WITH (32) MODULES-OPTIMIZERS, (1) INVERTER (SE7600), AND (1) LG ENERGY STORAGE BATTERY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29429	15041-10000-29311	1801 W OLYMPIC BLVD	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.05046	-118.27663	PC FOR POWER. ADDING ONE 1200A DISTRIBUTION BOARD, TWO AT'S , CHANGE OF USE OF A 175 KVA GENERATOR TO EMERGENCY LIFE SAFTY GENERATOR AND ADDING SOME PANELS FOR FUTURE LOADS IN CITY NATIONAL BANK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29430	11041-10000-02357	3782 S FIGUEROA ST	90007	9	117A201     4	5037029001	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.01625	-118.28257	TI in an existing restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29431	10041-10000-17466	5018 E YORK BLVD	90042	14	156A225   317	5477001005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1834.00	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	09/03/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.12122	-118.20628	TI in an existing commercial space.  Plan check is for T-24 Energy Calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29432	15041-20000-19234	12001 W CHALON ROAD A 202	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.08469	-118.4849	Plan check for Title 24 only in existing space class room; Total area: 572 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29433	19041-10000-13802	9543 S COMPTON AVE	90002	15	093A213   172	6048004046	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			04/16/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	33.94954	-118.24646	NEW 17 UNITS APARTMENTS BUILDING WITH TWO LOW INCOME HOUSING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29434	12041-20000-26635	3601 S CRENSHAW BLVD	90016	10	120B185  1155	5046001040	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.02383	-118.33529	New Coin Laundry in existing building.  Install new 800A service, panels, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29435	18041-20000-01180	8440 N BALBOA BLVD Suite 103	91406	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.22397	-118.50243	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first time tenant. Total lighting area = 1,315 sq. ft.Note: Building application has been generated under 18016-20000-00997	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29436	13041-10000-36278	1001 S CROCKER ST 4	90021	14	124-5A211 211	5132011044	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.03489	-118.25066	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 429 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29437	15041-20000-40180	237 E SHERMAN CL	90291	11	105A145    74	4227011017	RW1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	33.98327	-118.46591	Plan check for the addition of a 3 kWac system onto an existing 3 kWac system, for a system total of 6 kWac. New system consists of (1) inverter, (1) load center, and (14) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29438	19041-10000-31875	6330 W SAN VICENTE BLVD STE 510	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.06116	-118.36804	energy pc for Interior tenant improvement to (E) office suite 510.  area of scope 910sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29439	19041-20000-10867	12244 W OXNARD ST PV3	91606	2	177B165   746	2340003017	RD3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.17921	-118.4005	Plan check for PV roof mounted system, system size: 1.52KW with 5 PV modules and 5 microinverters. Unit number 3.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29440	12041-10000-23043	111 S THE GROVE DR	90036	4	138B177  1129	5512003036	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.0734	-118.35657	Plan check 228KW roof mounted photovoltaic system for Farmers storage facility. Site in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29441	16041-20000-31803	9127 W THRASHER AVE	90069	4	147B169   696	5560011019	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.09751	-118.38975	PLANCHECK FOR POWER ONLY. NEW SINGLE FAMILY RESIDENCE. 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29442	12041-20000-25669	5240 N LANKERSHIM BLVD	91601	4	171B173  1422	2350018091	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.16613	-118.3751	Plan check for addition of one fire alarm panel (booster) and 12 devices to an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29443	18041-10000-43146	801 S GRAND AVE #550	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.04581	-118.25842	TENANT IMPROVEMENT AT PORTION OF 5TH FLOOR IN SUITE #550 (APPROX. 5,936 SF).INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT:  18016-10000-32877	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29444	11041-10000-09703	1800 CENTURY PARK EAST 12TH FLR	90067										Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Approved	07/07/2011 12:00:00 AM				T.I.  EXISTING OFFICE SPACE ON THE 12TH FLOOR.  RELOCATING, REPLACING, AND ADDING LIGHT FIXTURES.  PLAN CHECK IS FOR TITLE 24 AND EMERGENCY LIGHTS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29445	19041-20000-36745	5727 N CANOGA AVE BLDG 8	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	ADDRESS	34.17529	-118.5978	PV2 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING APARTMENT BUILDING #8. SYSTEM SIZE IS 7.56 KW DC/6.952 KW CEC AC. SCOPE OF WORK CONSISTS OF (21) PV MODULES, A 100A PANEL, AND (2) 3 KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29446	14041-10000-04944	17077 W BOLLINGER DR	90272	11	126B121   348	4419016027	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.04244	-118.55105	PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(17) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29447	18041-10000-14552	3831 S HUGHES AVE #501	90232	5	120B165  1276	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.02242	-118.39823	PLANCHECK FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT TO DENTAL OFFICE. acceptance testing required.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29448	15041-10001-22828	5422 W CARLIN ST #3	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/30/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON COMMERCIAL BUILDING.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29449	10041-20000-18003	440 S VERMONT AVE #112	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.0659	-118.29143	Plan check power and energy for first time tenant, suite #112. New bakery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29450	17041-10000-32781	300 WORLD WAY T330-T331	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC for T24 only for retail TI in LAX. Total of 252 sqft. B 17016-10000-26650.Installing new ligths, circuits and panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29451	16041-20000-08169	9310 N ELBEN AVE	91352	7	198B185    48	2545025012	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.23795	-118.33546	Install a roof mounted solar array on a SFD. System size: 10kW. (38) 255W pv modules.Solar clearance done under building permit #16016-20000-03426.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29452	14041-10002-17249	1550 N EL CENTRO AVE	90028	13	148-5A189 303	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.09961	-118.32359	"08/17/16Changes to an approved set of plans. Changes include adding two new panels (panels ""LR-K"", & ""HR-K""), new lights, and receptacles for the Rooftop Bar/Kitchen space. New scope of work is under new engineer.  ((((  fire alarm variance has not been filed.PC FOR POWER AND ENERGY. New High Rise Apartment Building with Future Restaurant and Retail at the Ground Floor. 200  UNITS IN 14 TYPES.see additional comments."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29453	17041-20002-18634	5060 N AMESTOY AVE	91316	5	171B133   648	2258014006	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.16199	-118.50531	9.13.2017 - Plan check for changes to approved set. Upgrade inverter from ABB 4.2kW to Delta 5.2kW (ungrounded). Revise pv module stringing (total number is the same). Change modules from LG 315W to Solarcity Standard 325W. Changes clouded.======Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 4.2 kWac and consists of (1) inverter, (16) modules, (1) load center, and (1) Tesla Powerwall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29454	16041-10002-36743	447 S HEWITT ST	90013	14	127-5A215 356	5163022017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.04216	-118.23526	(THIS IS PLAN CHECK ONLY, NO SUPPLEMENTAL PERMIT NEEDED) PC for power changes to approved set. Changes include reduction and relocation of equipment, revise load schedule due to reduction and relocation of load, revision on single line diagram to show New pnel B1 (this panel is not part of this submittal, will be submitted under separate application for oFfice submittal)  to existing switchboard MSA.  Changes are noted under Delta-7&8	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29455	12041-10000-10359	9301 N TAMPA AVE #58	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	09/07/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT FOR NEW STARBUCKS COFFEE UNIT #58	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29456	11041-10000-12953	525 E ANAHEIM ST	90744	15	030B209     7	7423023004	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM	09/07/2011 12:00:00 AM		Issued	09/07/2011 12:00:00 AM	ADDRESS	33.78047	-118.25663	OIL PRODUCTION SITE:  INSTALLATION OF CIRCUIT BREAKERS, TRANSFORMERS, CABLE TRAYS & OTHER ANCILLIARY, AND RE-ROUTING AND REWIRING OF CABLES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29457	16041-20000-24249	11136 W CANTLAY ST	91352	2	183B173    59	2315028005	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Apartment			07/11/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Issued	07/19/2016 12:00:00 AM	ADDRESS	34.20199	-118.37378	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29458	16041-20000-45614	6001 N DE SOTO AVE	91367	3	177B105    72	2149005033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.17944	-118.59076	Plan check for energy only. New lighting in proposed restrooms located within proposed storage units. 140sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29459	19041-10001-46416	1405 N CABRILLO AVE	90731	15	021B197    77	7445002033	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	33.75648	-118.29602	PLAN CHECK ONLY. RELOCATING LOAD CENTER AND AC DISCONNECT TO THE SOUTH SIDE OF THE BUILDING. ***PV1. NEW ROOFTOP SOLAR SYSTEM CONSISTS OF 22 AC MODULES (SUNPOWER SPR-A400-G-AC)TOTAL SYSTEM SIZE IS 8.80KWdc / 7.68KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29460	17041-20000-33503	14631 W MINNEHAHA ST	91345	7	207B149   811	2648013037	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.26055	-118.45142	Plan check for solar pv system, roof-mounted array on SFD.5.2kW ungrounded system. (24) 300W pv modules.Using a standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29461	18041-20000-32160	62 N BEVERLY PARK	90210	4	156B161    79	4386013014	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2018 12:00:00 AM			PC Approved	10/25/2018 12:00:00 AM	ADDRESS	34.12129	-118.41683	Plan check for power only. Project site is a 2-story single-family dwelling. Work includes a 1,200-amp service.Note: Building application has been generated under 16010-20000-05799. Electrical permit fees shall be paid under the combination building permit. This application is for plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29462	13041-10000-32966	9509 N RUBIO AVE	91343	12	201B137   985	2686010***	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.24339	-118.49617	PV1, Install  4.24 kw DC roof-mounted solar array for a 2 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 16 modules: Suniva OPT265-60-4-1B0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29463	17041-20002-28602	11433 W ALBERS ST	91601	2	174B169  1079	2350007049	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.17056	-118.38016	10-23-2018 Changes to an permitted set of plan, Changes include addition of 2 circuits(Dryer/Laundry and Oven) in each unit for 59 units. All Changes has been clouded as delta C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29464	16041-20000-24555	2802-2806 S ELLENDALE PL	90007	9	123B197  1598	5055012003	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			07/14/2016 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.02947	-118.28859	PLANCHECK FOR POWER AND ENERGY. (n) 3-story type V-A  7 unit Apartment bldg w/ parking garage New 600 Service to feed new apartment and 2 existing SFDs on lot. Total area: 3870 sq ft. Fire alarm variance on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29465	10041-10000-02690	3015 S FIGUEROA ST	90007	9	121-5A203 221	5123010027	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM			PC Info Complete	02/18/2010 12:00:00 AM	ADDRESS	34.0248	-118.27838	PLAN CHECK T-24 ENERGY FOR EXISTING TAKE-OUT RESTAURANT (YOGURT SHOP).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29466	18041-20000-05410	12812 W FRIAR ST	91606	2	177B161    53	2332002011	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Re-Activate Permit	11/05/2019 12:00:00 AM	ADDRESS	34.18549	-118.4124	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (19) modules, (1) load center, and (1) Tesla PowerWall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29467	10041-10000-08111	2029 S CENTURY PARK EAST 29th floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/01/2010 12:00:00 AM		Permit Finaled	08/20/2010 12:00:00 AM	ADDRESS	34.05956	-118.41375	Ti in an existing office building, on 29th floor. Plan check for T24 and Energy. (Variance was submitted to separate the fire alarm system.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29468	16041-10001-07425	1380 W CAPITOL DR	90732	15	021B193    53	7445004***	R3-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	33.75409	-118.30814	PERMIT IS $0 DUE TO DEPARTMENT ERROR. ADDRESS CHANGE. REMOVING UNIT 303 FROM ADDRESS.(((PC FOR A FIRE ALARM PANEL REPLACEMENT. ALL OTHER FIRE ALARM EQUIPMENT ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29469	13041-10000-09626	843 N DETROIT ST	90046	5	141B181    64	5525003018	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Expired	06/29/2015 12:00:00 AM	ADDRESS	34.08646	-118.34528	PV1 5.61KWDC 2STORY DUPLEX UNGROUNDED NONSTNRD 22KAIC upgraded panel 200A 120/240VAC. inverter power-one-pvi-3-outd-s-us (2x). pv modules suntech power STP255s-20/WDB (22x). permit 12041-10000-28073 covers 2 inverters, 1 service0-200, and 22 pv modules. difference covered under inspection fees	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29470	17041-10001-29207	700 W 7TH ST G620	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	JUICE BAR. NEW LIGHTING. PERMIT UNDER MASTER. THIS IS PLAN CHECK ONLY FOR T24 REVIEW. PERMIT TO CORRECT ADDRESS ON PERMIT CARD TO REFRLECT UNIT G620	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29471	19041-10000-30785	9248 N ETON AVE	91311	12	198B105    97	2746010011	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.23926	-118.59458	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29472	12041-10000-14446	845 W 12TH ST	90731	15	015B197  1426	7454022900	OS-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	33.73321	-118.29553	Plan check for energy only. Outdoor recreation center. 14597 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29473	17041-10001-19821	11134 W WICKS ST	91352	7	201B173   249	2538017002	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			Reviewed by Supervisor	06/19/2017 12:00:00 AM	ADDRESS	34.24867	-118.37346	Expedite fees only.       Installation of new roof mounted solar PV system on existing single family dwelling.  Two Delta Soliva 5.2 TL inverters with 22 Solarcity Standard SC325 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29474	18041-10000-45895	7251 N VARNA AVE	91605	2	186B157   577	2328026053	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.20287	-118.42485	REMOVE OUTDOOR EXISTING HID FIXTURES  AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29475	12041-10000-28393	2436 N CLAREMONT AVE	90027	4	150B201  1315	5433018006	R2-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.10396	-118.27427	New 2.4 kw roof mounted PV for a single family. X-formerless INV with optimizer. (PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29476	17041-10000-29846	8850 N GLENOAKS BLVD	91352	7	195B177   361	2404008033	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.2298	-118.36611	REPLACE LIGHTING FOR LED TYPE. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29477	18041-10001-44584	4955 N CORBIN AVE	91356	3	171B117   546	2175014046	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Tarzana	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.1609	-118.56309	FEE EXPEDITEPLAN CHECK FOR ROOF MOUNTED PV SYSTEM(19KVA) CONSISTING OF 2 CENTRAL INVERTERS(SE7600H-US AND 11400H-US) WITH  70 MODULES WITH POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29478	13041-10000-25223	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	TITLE 24 PLAN CHECK ONLY.  2 STORY BUILDING. WORK ON SECOND FLOOR. RETAIL STORE (MALL). 2150 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29479	10041-20000-22755	10331 N SEPULVEDA BLVD	91345	7	204B145   114	2649018001	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1097.00	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	03/16/2011 12:00:00 AM	ADDRESS	34.25861	-118.46769	PLAN CHECK POWER AND ENERGY FOR CHG OF USE FROM RETAIL TO DENTAL OFFICE. EXISTING SERVICE AND PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29480	14041-10000-06041	1106 1/2 S EUCLID AVE	90023	14	121-5A223 195	5190006023	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.02643	-118.20987	PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PVI-3.6-OUTD-S-US-Z-A(17) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29481	15041-20001-31204	21440 W VILLENA AVE	91364	3	168B105   623	2171002022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM			PC Approved	10/08/2015 12:00:00 AM	ADDRESS	34.15611	-118.59793	Expedited per customer request.PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(23) Hanwha G3-270W Modules(1) Solar Edge SE6000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29482	16041-10000-19281	1441 W BRETT PL	90732	15	021B193    32	7445004***	R3-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	33.75648	-118.30862	PC FOR AN EXISTING FIRE ALARM SYSTEM TO AN EXISTING APARTMENT BUILDING. SCOPE INCLUDES 1 NEW FA PANEL, AND 2 FA DEVICES ON THE UPPER LEVEL PARKING GARAGE. ALL OTHER FA DEVICES ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29483	15041-20001-31621	846 N SIERRA BONITA AVE	90046	5	141B177    39	5526003016	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.08667	-118.35415	7/16/2018changes to an approved set of plans.  changes noted delta 1 only.  changes to reflect field conditions and revisions to energy calculations and lighting fixtures. (((Plan check for power and Title-24 (energy).  Total area = 5,250 sq. ft. (conditioned) + 3,470 sq. ft. (unconditioned) + 1,860 sq. ft. (hardscape).New electrical distribution system for new elderly care facility with 8 guest rooms (10 beds) and underground parking area.  Low-rise building with 600 A service and backup generator.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29484	10041-10001-21673	7857 W MANCHESTER AVE	90293	11	096B153   463	4115024014	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Apartment			08/10/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	33.95994	-118.43455	Modification to an approved set of plans.  Changes include new power equipment (clothes dryers for all 32 units) and changing feeders from copper to aluminum.  <<<<<<New 32 unit condominium building>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29485	19041-20000-13870	3022 1/4 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29486	13041-20000-04837	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM	08/12/2013 12:00:00 AM		Permit Closed	08/26/2015 12:00:00 AM	ADDRESS	34.30363	-118.45814	Plan check power and energy for existing supermarket warehouse with two existing services. New 1200 amp service, circuits, panels, and equipment added.  <<<<<Three panel schedules are missing, Additional fees may need to be collected>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29487	13041-10000-15017	3965 N CARPENTER AVE	91604	2	162B169   278	2369016018	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Apartment			06/07/2013 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.1422	-118.39129	PLAN CHECK POWER AND ENERGY FOR NEW 4 STORY 6 UNIT APARTMENT BUILDING OVER SUBTERRANEAN GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29488	17041-10000-27828	10250 W SANTA MONICA BLVD #1380	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK new space build out-Tenant Moleskine	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29489	16041-10000-40111	20910 W VANOWEN ST	91303	3	180B109    35	2148027046	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.19356	-118.58888	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR PARKING SPACE. TOTAL AFFECTED AREA IS 27025.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29490	16041-20001-44723	4441 W SUNSET BLVD	90027	4	147A201   110	5542009016	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM			PC Info Complete	08/24/2018 12:00:00 AM	ADDRESS	34.09777	-118.28615	08-24-2018 Changes to an approved set of plans, Changes include addition of fan coil in Elevator Mech room, and remove scope of work remove HVAC branch circuit conductors for space A, B, C,  and D. All Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29491	10041-20000-18260	6250 W HOLLYWOOD BLVD #500	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/15/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.10133	-118.32547	"PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT. NEW BEAUTY SALON (SUITE #500) AT THE ""W"" HOTEL.  HIGH RISE BUILDING."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29492	14041-10001-16148	2644 E ROSEVIEW AVE PV2-APT2	90065	1	145-5A217  90	5453003054	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			08/15/2014 12:00:00 AM			PC Info Complete	08/18/2014 12:00:00 AM	ADDRESS	34.09342	-118.22769	(((8/15/2014 - Supp. app. for plan check for roof mounted solar PV array at request of inspector.  Plan was originally submitted to express permit.  Main service panel is 600A. Type changed to apartment. PLAN CHECK ONLY)))Master permit work description:  INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 2.04KW. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.***APT. # 2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29493	11041-10000-15321	308 S LORING AVE	90024	5	138B153   101	4359007002	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	11/02/2011 12:00:00 AM	ADDRESS	34.07642	-118.43495	3.8 KW photovoltaic system on roof of single family house.  Enphase system, using inverter type 215.  16 modules and 16 inverters.  A variance to install Enphase Model No. 215 micro inverters was submitted on July 21, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29494	18041-30001-40581	1665 E I ST	90744	15	033B213   899	7428033906	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	33.78247	-118.24127	PC FOR NEW  OUTDOORS LIGHTING IN PARKING LOT. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER. TOTAL AFFECTED AREA 18700 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29495	18041-10000-27464	2801 W SUNSET PL	90005	10	133-5A201  35	5077013034	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2122.04	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	08/24/2021 12:00:00 AM	ADDRESS	34.0609	-118.2845	Install new Methane Mitigation/Detection system, (1) control panel, (87) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29496	15041-10000-06134	811 W WILSHIRE BLVD 800	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Issued	03/03/2015 12:00:00 AM	ADDRESS	34.04973	-118.2584	Energy plan check for an existing office (#800)  T.I inside a high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29497	19041-20000-39973	2408 S BROADWAY	90007	9	121-5A205 156	5126035003	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.02694	-118.26851	T.I to an existing comercial building title-24 P.C only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29498	19041-20000-16541	555 S ALEXANDRIA AVE	90020	10	135B197   992	5502019019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	06/09/2020 12:00:00 AM		Permit Finaled	10/26/2020 12:00:00 AM	ADDRESS	34.06383	-118.29817	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a change of use from retail to coffee shop/first time tenant. Total lighting area = 1,447 sq. ft.Note: Building application has been generated under 19016-10000-09985	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29499	17041-10000-36352	3256 N DOS PALOS DR	90068	4	159B181   827	2429010023	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.12848	-118.34859	PC for SFD new rooftop 11.4kW PV system. Installing new SE11400A-US central inverter with 38 modules with optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29500	10041-30000-06364	11350 W OLYMPIC BLVD	90064	11	126B153  1163	4260018001	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Issued	04/08/2010 12:00:00 AM	ADDRESS	34.0373	-118.44237	Plan check power for installation of new 100A service for existing off-site billboard sign. Demo and reinstall existing 800A service to existing board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29501	19041-20000-51714	3724 N LITCHFIELD LANE	91356	3	162B117   392	2177043010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.1367	-118.55187	INSTALL (2) TESLA ENERGY STORAGE SYSTEM ON EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29502	15041-20000-26160	2000 S AVENUE OF THE STARS	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for Title 24 only replace light fixtures with LED. Total area: 16,722 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29503	13041-20000-35213	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	T24 for existing office space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29504	17041-10000-35326	1038 E VERNON AVE	90011	9	112-5A209  62	5108028008	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.00369	-118.25748	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 10800 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29505	18041-20000-42538	18242 W BERMUDA ST	91326	12	207B125   180	2715010018	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.2661	-118.53119	PV1.  Install 5.2 kW roof mounted grid tied PV system and 27 kWh energy storage system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29506	19041-10000-36432	9189 N DE GARMO AVE	91352	6	198B173   125	2408034042	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/23/2022 12:00:00 AM	ADDRESS	34.23604	-118.37603	CLOSED-COUPLED SUBSTATION RELOCATED  AND ITS 4160KV/480V  3000KVA  TRANSFORMERAGAIN SUPPLIES 4000A  DB WHICH SUPPLIES DBB AND 2000A  DBH (WAS DBD); DBH NOW SUPPLIES 1200A  DBD AND A FUTURE LOAD, CHANGES ARE CLOUDED AS DELTA 1(((((((FOR A RECYCLING FACILITY, NEW 4160V SERVICE WITH SERVICE EQUIPMENT TO SUPPLY EXISTING LOADS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29507	18041-10000-00231	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Issued	10/09/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC for T24 only for new lights and receptacles in restroom. corridor and stairs. Installing new lights, receptacles and routing conduit.17014-10000-05320.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29508	14041-20001-04714	8316 N GAYNOR AVE pv1	91343	12	192B141   449	2673018054	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.22184	-118.48181	][] expedited per applicant request ][][pv1, roof mounted solar installation, interconnecting with (E) 200a main service PNL. downsizing main breaker for tie-in. ungrounded system, sized @ 5.75 kW DC, with (23) canadian solar #cs6p-250px, (23) OP300 power optimizers, (1) solaredge #SE5000a-us-zb-u	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29509	15041-20000-41180	7902 N WOODLEY AVE	91406	6	189B141   151	2206007008	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.21417	-118.48347	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERICIAL BUILDING (OFFICE/STORAGE/RESTROOM SPACE). SCOPE INCLUDES ADDING NEW LIGHTING. TOTAL AREA IS 2032 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29510	18041-20002-07606	5839 N CRANER AVE	91601	2	174B173   157	2415002016	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.17695	-118.36938	Revisions to approved set of plans.  Removal of performance meter from plan design.  $0 plan check fee per State Senate Bill SB 1222. (((3/8/2018 Changes to an approved set of plans. Changes to downsize system to 10.03 kWdc/7.8 kWac interconnected with msp.(34) modules(34) micro inverters)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29511	19041-20000-35408	19901 W NORDHOFF ST BLDG 11	91324	12	195B113    15	2782037034	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.23201	-118.56708	Plan check for Title 24 energy only Building 11 for portion of manufacturing/wearhouse/office building, scope of work apply to clouded area only, everything else outside clouded area is existing to remain. Total area: 6560 sq ft. B#19016-20000-25578	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29512	11041-10000-24455	1452 N VIA CRESTA	90272	11	132B125    19	4420040002	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.05653	-118.53709	Ground mounted Photovoltaic System for a single family residence with 80 Enphase M215 Micro-inverters.  Variance to install Enphase M215 inverters. Existing permit under #11041-30000-09481. Additional permit for subpanel and 80 micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29513	11041-20002-08633	189 S THE GROVE DR Ste# H80	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Info Complete	10/04/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	PLAN CHECK FOR REVISION TO APPROVED PLANS. REVISION ARE CLOUDED DELTA 5. ADDITIONAL CKTS ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29514	14041-10000-14698	6521 W DAY ST	91042	7	204B201   957	2570001014	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Expired	07/15/2016 12:00:00 AM	ADDRESS	34.25278	-118.27433	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. NON STANDARD PLAN.(1) SOLAR EDGE SE3000(12) TRINA SOLAR TSM 255(12) POWER OPTOMIZERS P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29515	12041-10001-00738	17056 W GRESHAM ST	91325	12	195B133   401	2690010012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	03/08/2012 12:00:00 AM	ADDRESS	34.2296	-118.50465	Supplement permit for service panel upgrade to 225A.(New rooftop photovoltaic systems, for a single family residence.  8.5kw with two inverters.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29516	13041-10000-24163	9157 N DE SOTO AVE UNIT # A	91311	12	198B109   148	2746009047	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.23726	-118.5888	TITLE-24 PLAN CHECK FOR AN EXISTING SANDWICH RESTAURANT TO YOSHINOYA RESTAURANT.DESIGN-BUILD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29517	18041-20001-06188	6376 W 80TH PL	90045	11	099B165   705	4108026031	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	33.96609	-118.39883	SUPPLEMENTAL FOR EXPEDITED AND BATTERY BACK UP SYSTEM WITH 2 NEW PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29518	17041-20000-21886	14828 W RAYEN ST #1-14	91402	6	195B149   279	2653005002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Apartment			06/28/2017 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.23171	-118.45633	New 3-story, 14-unit apartment building.  800 A 120/240V 1ph-3w service.  Building permit filed under 16010-20000-03664	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29519	19041-20000-40255	19139 W STRATHERN ST	91335	3	189B121   167	2104003027	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.21574	-118.55074	Plan check for PV roof mounted system, PV System size: 11.55KW DC, 10.64KW AC CEC with 35 PV Modules and 35 microinverters connected to existing 400A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29520	15041-20001-00884	5329 N MECCA AVE	91356	3	171B125   108	2161016031	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM			PC Approved	03/02/2015 12:00:00 AM	ADDRESS	34.1681	-118.53769	Expedited per customer request.PV1. Install roof mounted PV system sized 7.92 kW. Interconnected with main service pannel. (33) SolarWorld plus SW-280 Mono Modules(33) Enphase Energy M250 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29521	15041-10000-24508	523 W 6TH ST 7TH FLOOR-STE# 728	90013	14, 8	129A209    44	5149030002	C2-1VL, C2-4D	Central, South Los Angeles	Central City, South Los Angeles	Downtown Los Angeles		2077.10, 2377.10	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	PC FOR ENERGY ONLY. T-24. FOR A COMMERCIAL HIGH RISE BLDG ON 7TH FLOOR SUITE #728.   TOTAL SQ FT = 2520.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29522	16041-10000-22167	11990 W SAN VICENTE BLVD 300	90049	11	129B141   244	4265007050	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.05206	-118.47239	PC for energy only to a commercial building (offices) lowrise. Suite 300 on 3rd floor. Adding new lighting and receptacles. Total sqft = 1992	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29523	14041-20000-19865	14117 W HUBBARD ST Unit #5	91342	7	219B153   199	2508027029	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.29849	-118.44081	Plan check for energy only. Applicant chose to comply with 2013 Energy code standards. New lighting in existing single story office space/waiting area. 1,316sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29524	11041-20001-11098	7901 N WOODLEY AVE	91406	6	189B141   129	2205004039	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM			PC Approved	06/13/2011 12:00:00 AM	ADDRESS	34.21426	-118.48387	Plan check T24 Energy (general/emergency) lighting for office/warehouse showroom remodel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29525	19041-10000-16998	18310 W OXNARD ST	91356	3	177B125   690	2157002131	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	05/13/2019 12:00:00 AM	ADDRESS	34.18003	-118.53125	PLAN CHECK FOR POWER FOR SERVICE EQUIPMENT FOR FEED-IN TARIFF PV2 SYSTEM UNDER PERMIT LISTED BELOW RATED AT 1200A 120/208VPERMIT 19041-10000-17000PLAN CHECK FOR A ROOF MOUNTED 333KVA PV2 SYSTEM CONSISTING OF 4 INVERTERS(3-SE99.9K-US & 1-SE33.3K-US) WITH 1092 MODULES USING 546 OPTIMIZERS(P850)PLANS TO BE ASSIGNED TO EDWIN OR JOHN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29526	19041-20001-28363	3845 W TRACY ST	90027	4	150B201   742	5433021005	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	Apartment			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Issued	10/01/2019 12:00:00 AM	ADDRESS	34.10678	-118.27631	PV2. INSTALL 7.04 KW DC PV SYSTEM WITH (22) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H).NOTE: INSPECTION FEE PAID ONLINE UNDER 19041-90000-28363	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29527	14041-10000-09237	2740 E 5TH ST	90033	14	124-5A225  55	5185010002	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.03686	-118.2077	PV1 5KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(20)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29528	14041-20000-00288	1447 W AVON TER	90026	13	144B213   732	5415008005	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Expired	02/17/2016 12:00:00 AM	ADDRESS	34.0894	-118.24564	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29529	18041-10000-41854	341 N VAN NESS AVE	90004	4	138B189   219	5522027018	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.07738	-118.31586	NEW SFD ROOFTOP PV SYSTEM 12.285 DC KW ARRAY, (1) 11.4 AC KW INVERTER, (39) 315W MODULES WITH P400 POWER OPTIMIZER, CONNECTED TO A 225A MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29530	13041-10000-30847	6404 W WILSHIRE BLVD	90048	5	135B173   870	5088013022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.06351	-118.36852	REPLACING FIRE ALARM PANEL FROM EST IRC-3 TO NEW EST-3 PANEL FOR A HIGH RISE BUILDING. ALL EXISTING FIRE ALARM DEVICES TO BE REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29531	16041-10000-25220	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.20615	-118.41279	Plan Check for Power and Energy. TI to an (E) Manufacturing/Office spaces. New Electrical equipments with new loads > 400A. Total affected area: 49,480 sq.ftB# 16014-10000-03394	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29532	18041-10000-03638	1540 S BEDFORD ST	90035	5	129B169   663	4303012019	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			01/31/2018 12:00:00 AM			Reviewed by Supervisor	02/28/2018 12:00:00 AM	ADDRESS	34.05033	-118.38095	PC FOR NEW 3-story apartments (6 units) type V-A  over 1- story basement FOR POWER AND ENERGY.NEW SERVICE AT 600A 120/240 3PH. TOTAL AFFECTED 7679 SQ. FT (INDOOR & OUTDOOR).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29533	19041-10001-42091	10416 S WILMINGTON AVE	90002	15	090A215   281	6066001019	C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM			Corrections Issued	12/17/2019 12:00:00 AM	ADDRESS	33.94099	-118.23889	CHANGES ON APPROVED SET ON PV PLANS.CHANGES INCLUDE RELOCATION INVERTER, MAIN SERVICE PANEL, AND AC DISCONNECT.  ADDRESS DELTA 1 CHANGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29534	17041-20000-33351	3704 N CAHUENGA BLVD	91604	4	159B177    62	2425001053	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.13554	-118.36147	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is an addition. Total lighting area = 1,197 sq. ft.Note: Building application has been generated under 16014-20000-05083	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29535	17041-20000-41997	1501 N SUMMITRIDGE DR	90210	5	147B157   193	4355005039	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	34.09868	-118.41997	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 38.9 KW.APPLICATION ERRONEOUSLY ASSIGNED AS ROOF MOUNTED PV SYSTEM - SEPARATE EXPRESS PERMIT FOR GROUND MOUNT SYSTEM ISSUED UNDER 17041-20000-42967.  PLAN APPROVAL UNDER THIS APPLICATION.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29536	17041-20000-00675	1577 W FAIR PARK AVE	90041	14	160-5A227 212	5689025019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Expired	09/13/2023 12:00:00 AM	ADDRESS	34.13394	-118.20059	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29537	13041-10001-30617	265 S GRAMERCY PL	90004	4	135B193   187	5516016015	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.06924	-118.313	][][]expedited per applicant request ][][]PV1, ROOF-MOUNTED SOLAR ARRAY ,INTERCONNECTING WITH NEW 200A SERVICE(SERVICE UPGRADED FROM 100A) IN SINGLE-STORY HOUSE. MICROINVERTER SYSTEM ; SIZE IS 7.5kW DC AND 6.48 kW AC, WITH (30) MODULES ( HANWHA HSL60P6-250) , (30) ENPHASE M215 MICROINVERTERS.IMPORTANT: existing permit is under 13041-20000-22302 which was initially a central inverter plan; charges for 30 modules, (2) inverters were already accounted for and shall not be charged again upon final fee period.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29538	11041-10000-00376	426 S HILL ST	90013	14	129A211    18	5149025008	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Expired	02/26/2013 12:00:00 AM	ADDRESS	34.04946	-118.25094	CHANGES MADE TO PREVIOUSLY APPROVED SET OF PLANS, NEW PANELS, FEEDERS AND TRANSFORMER INDICATED IN RED. COPY OF APPROVED SET SIGNED BY M.ZANDI IS PROVIDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29539	13041-10000-25161	1501 W FRANCISCO ST	90501	15	057B193    26	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	33.8498	-118.30433	INSTALLATION OF (4) 250 KW FUEL CELLS TO EXISTING ELECTRICAL SYSTEM. BUILDING APPLICATION REFERENCE NUMBER 13020-10000-02201.  EXPEDITED PLAN CHECK PER APPLICANT REQUEST.  09/24/2013	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29540	16041-20002-14403	17150 W NANETTE ST	91344	12	222B133   635	2602019057	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.30167	-118.50599	06-27-2016 Changes of an approved set of plans. Changes include solar module layout changes. ((((((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(41) LG NEON MODULES(41) POWER OPTIMIZERS(1) SOLAREDGE INVERTER 11400W)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29541	18041-10000-05579	3018 S MCCONNELL DR	90064	5	123B165    85	4316028020	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.03681	-118.40134	PV1, ROOF MOUNTED SOLAR SYSTEM USING AC MODULES. (42) AC MODULES TOTAL, SYSTEM SIZE IS 15.2KWDC AND 13.4 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29542	11041-20000-06944	15260 W VENTURA BLVD 1840	91403	5	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.15356	-118.4658	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TI OFFICE #1840	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29543	18041-20001-44271	20319 W HEMMINGWAY ST	91306	3	189B113   685	2107025054	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.21399	-118.57602	05-20-2019 Changes to an approved set of plans, changes include addtion of 1 PV Module(Total of 41 PV module) and change to 1 inverter(11.45KW) to existing PV system, update PV system size: 13.53KWFees $ 0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29544	13041-10000-27820	432 N FAIRFAX AVE	90036	5	141B177  1334	5527030021	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.07914	-118.36128	[][][]TITLE-24 PLAN CHECK ONLY; CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGES INCLUDES REDUCING NUMBER OF FIXTURES AND LIGHTING LAYOUT. TOTAL AREA IS APPROXIMATELY 3000 SF. ORIGINAL APP UNDER 09041-10000-18276 ][][]-AS-BUILT SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29545	16041-10000-01595	5735 W ADAMS BLVD	90016	10	123B173   824	5048005039	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.03262	-118.36814	PV2INSTALL ROO FMOUNTED PV SYSTEM SIZED 17KW INTERCONNECTED WITH MSP.(68) SOLARWORLD 285 MODULES(68) ENPHASE 250 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29546	19041-10000-26645	1501 W SUNSET BLVD	90026	13	139-5A209 235	5419027007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1973.00	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	03/10/2020 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.07605	-118.2552	energy pc for Tenant improvement of restaurant. area of scope 815sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29547	13041-10000-30655	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	Building 4 of 5:  TACTIAL RANGE. INSTALL NEW ELECTRICAL PANELS, NEW CONVENIENCE RECEPTACLES. FEES TO BE VERIFIED BY PLAN CHECKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29548	16041-20001-21189	10353 W DIAMOND ST LOT 5	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29549	14041-20000-14966	17509 W RUSHING DR	91344	12	219B129   493	2608014032	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.29549	-118.51619	PV1INSTALLATION OF ROOF MOUNTED PV SYSTEM SIZED 3.45KW WITH (16) ENPHASE 215 MIROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29550	19041-20001-22477	8360 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM				SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY. RELOCATION OF AC DISCONNECT AND J-BOX.<<PV1.  Install 2.8 kW roof mounted grid tied PV system for new home construction.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29551	16041-10000-35118	10928 N BATON ROUGE AVE	91326	12	210B121   694	2718016001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.26882	-118.55104	PV1. NEW SOLAR SYSTEM FOR EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.42KWdc / 11.52KWac.(36)AC MODULES-SPR-X21-345-C-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29552	19041-20000-36740	5727 N CANOGA AVE BLDG 6	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	ADDRESS	34.17529	-118.5978	PV2 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING APARTMENT BUILDING #6. SYSTEM SIZE IS 10.8 KW DC/9.831 KW CEC AC. SCOPE OF WORK CONSISTS OF (30) PV MODULES, A 100A PANEL, AND (2) 5 KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29553	16041-10000-28479	8723 W ALDEN DR 2ND FLR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.0754	-118.38272	Plan check for power and Title-24.  Total area = 2,947 sq. ft.     T.I. to second floor of existing medical office building.  New office spaces and exam rooms.((B# 16016-10000-18537))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29554	16041-10000-29792	1115-1129 S BOYLE AVE PV	90023	14	123A221   272	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.0308	-118.22044	Fees are $0 due to senate bill 1222.((((((Plan check for Feed In Tariff PV roof mounted system on commercial Building with multi address 1115, 1121,1123, and 1129 Boyle Ave. System size: 240kW with 680 modules and 3 inverters(80kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29555	18041-10000-18981	1018 E OLYMPIC BLVD	90021	14	124-5A213 463	5132005027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Issued	05/22/2018 12:00:00 AM	ADDRESS	34.03383	-118.24667	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 4200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29556	14041-10000-07242	3580 N PASADENA AVE	90031	1	144A223   333	5446026006	M1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1994.00	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Expired	04/12/2016 12:00:00 AM	ADDRESS	34.08781	-118.21197	PLANCHECK FOR NEW FIRE ALARM SYSTEM.  1 PANEL AND 51 DEVICES. 1 STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29557	19041-10000-08268	10174 N RESEDA BLVD	91324	12	204B125   232	2731018018	P-1VL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.25585	-118.53588	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29558	15041-10000-26855	200 WORLD WAY TERM 2-ARRI LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 ARRIVAL LEV 1  SPACE 283Main scope is adding L2 fixture on the floor plan in addition to the newly approved permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29559	18041-10000-07404	5455 W HOLLYWOOD BLVD	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.10193	-118.30881	PLAN CHECK FOR T24 ONLY, PC FOR TENANT IMPROVEMENT TO (E) RETAIL STORE.TOTAL AFFECTED AREA 6054 SQ.FTB#18016-10000-06120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29560	19041-10000-27495	8330 N LANKERSHIM BLVD	91605	6	192B169   450	2632023020	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.22203	-118.38758	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29561	16041-10002-43717	1750 N GLENDALE BLVD	90026	13	144A209   317	5423005004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			12/12/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.08713	-118.25942	This is plan check only, permit is covered under master #16041-10000-43717. Changes to approved set, noted as Delta-6. Scope includes: reducing the breaker & fuse size of distribution boards MG1 & MG2. Updated load calcalulation is included.<<PC for new five story apartment with 70 units with two levels of subtarrenean basement.  PC for new 3000 A, 120/208 service.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29562	17041-10000-23901	1014 N WESTERN AVE	90029	13	144B193   933	5536022012	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.08893	-118.30893	INSTALL NEW FIRE ALARM SYSTEM (1) FA PANEL, (32) DEVICES TO A DAYCARE FACILITY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29563	17041-10000-04446	12715 W SEABEACH PL	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	33.97531	-118.41512	PC FOR A NEW FIRE ALARM SYSTEM FOR A  4 STORY, 6 UNITS CONDO  APARTMENT BUILDING. SCOPE INCLUDES 63 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29564	15041-10001-00791	19021 W MIRANDA ST	91356	3	174B121   144	2156012023	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.1753	-118.54832	Plan check expedited per applicant's request.(((Plan check for a PV1 roof-mounted PV system. System size is 13.2 kWac and consists of (2) inverter and (64) modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29565	16041-20000-15173	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	33.79072	-118.29449	PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORT. 58022 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29566	10041-10000-06289	945 N HILL ST	90012	1	135A215   101	5414005017	C2-2	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM			PC Approved	04/14/2010 12:00:00 AM	ADDRESS	34.06574	-118.23823	T. I. for a medical office (Basement, 1st, 2nd floor).  Install general and emergency lightings.  Plan check for energy only.  Existing permit # 10041-10000-05005.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29567	15041-20002-37727	18209 W PARTHENIA ST	91325	12	195B125   794	2769019041	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.2289	-118.52978	Revisions to approved set of plans.  Reduction in system size to (240) modules, change to # of inverters to (1) Growatt 20000TL3-US and (1) Growatt 36000TL3-US inverters, and multiple changes to conductor routing details and equipment layout.  Project is now properly identified as Feed-in-Tariff project per LADWP service letter.  Inverter voltage class output changed to 480V 3ph, connected to 240V 3ph service meter through isolating transformer. THIS IS PLAN CHECK ONLY. (((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERICAL ROOF-TOP. TOTAL SYSTEM SIZE IS 79.12KWdc/80.0KWac. (344) MODULES-SCHUCO MPE-230W (4) INVERTERS-GROWATT 20,000-UE (240V)(1) 200A SUBPANELNOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29568	10041-10000-15396	221 N OCCIDENTAL BLVD	90026	13	138A203   239	5156017023	R3-1	Central	Westlake	Rampart Village	YES	2086.10, 2086.20	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Closed	06/28/2011 12:00:00 AM	ADDRESS	34.07278	-118.27831	New building for film studio production.  New service, panels, and branch ciruits.  Plan check for power and energy.  NOTE: Service load and T-24 calculations will submit about a week from now (Contact Michael 714-813-9400).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29569	18041-20000-45080	5550 N BONNER AVE	91601	2	174B173  1076	2350005052	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	10/19/2020 12:00:00 AM	ADDRESS	34.17145	-118.37398	Plan check for new fire alarm system, total fire alarm devices: 146 and 1 FACPB#16010-10000-00385	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29570	17041-10000-27827	10631 N LINDLEY AVE	91326	12	207B125   312	2731008020	R3-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Issued	08/08/2017 12:00:00 AM	ADDRESS	34.2634	-118.52752	REMOVE METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES. TOTAL SQUARE FT 34450.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29571	19041-20000-42109	10520 N WHITE OAK AVE	91344	12	207B129   863	2733011027	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.26173	-118.51949	Plan check for PV roof mounted system, PV system size: 3.285KW DC, 3.0KW AC with 9 PV Modules and 1 inverter(3.0KW) connected to center fed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29572	17041-20001-34764	10155 N CASABA AVE	91311	12	204B113   343	2741006003	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.25542	-118.5762	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29573	14041-10000-26373	4947 W MELROSE HILL	90029	13	141B193   267	5535028003	R1-1-HPOZ	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.08528	-118.30683	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL STANDARD INVERTER PLAN. SYSTEM SIZE: 5.1 KW. (20) KYOCERA #KD255GX(1) ABB PV1 4.2 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29574	19041-10000-53298	1125 S HAUSER BLVD	90019	4	132B177  1144	5085006037	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.05503	-118.35445	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 12 MODULES (Q.PEAK DUO BLK- G5/SC315), 1 CENTRAL INVERTER (SOLIVIA 3.8TL), 2 ENERGY STORAGE SYSTEMS, AND 1 PANEL OF 200 AMPS SYSTEM SIZE: 3.78 KW DC; 3.8 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29575	17041-10000-17179	810 W 8TH ST	90731	15	015B197   536	7454001001	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	33.73709	-118.29488	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 8,100 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29576	10041-10000-22267	221 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04947	-118.22718	Solar voltaic system installed on the roof of the building.  Consists of 9 modules, 9 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29577	19041-10000-33580	2358 W COLORADO BLVD	90041	14	162A221    75	5686001007	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.13958	-118.21781	Plan check for a PV1 6kW roofmounted system with (21) modules, (1) inverter and (1) existing PV system interconnecting through the load center. Total system size with new and  existing system size is 11.00KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29578	13041-10000-32757	1500 W PACIFIC COAST HWY BLDG J	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING JTHIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29579	18041-10000-37524	26640 S WESTERN AVE STE N	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			Corrections Issued	10/02/2018 12:00:00 AM	ADDRESS	33.78015	-118.30862	PLAN CHECK FOR TITLE 24 ONLY FOR - CHANGE OF USE FROM OPTOMETRIST TO RESTAURANT (CAFE). TOTAL AFFECTED AREA = 1407 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29580	13041-20000-14762	13269 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW USING 15 MODULES MICROINVERTER STANDARD PLAN ENPHASE M215	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29581	13041-20000-17339	5900 W WILSHIRE BLVD #2800	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Change to lighting in an existing high-rise office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29582	17041-20000-31699	350 S GRAND AVE Flrs 2,4,5-,6,7	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Issued	11/06/2017 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for power and energy. Project involves multiple floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 107,774 sq. ft.Note: Building application has been generated under 17016-10000-25501	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29583	16041-20002-37052	7500 N DE SOTO AVE	91303	3	186B109   380	2113012006	RA-1, RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Issued	09/14/2017 12:00:00 AM	ADDRESS	34.20666	-118.58826	Supplemental permit for restroom lighting in existing church.  Plan check for energy.  ((((11/17/2016 Plan check for Title 24 only. Project site is an existing chruch. Project scope is a tenant improvement. Total lighting area = 4,370 sq. ft.*****Previous Work Description*****CHANGE OUT LIGHTS, EXIT LIGHTS AND BUG EYES.  PROJECT IS CONSIDERED A MODIFICATION IN PLACE AND DOES NOT REQUIRE TITLE 24 PLAN CHECK PER 141.0(b)(I)(iii))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29584	14041-20000-34908	8857 N PENFIELD AVE	91324	12	195B113   102	2782033010	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Expired	01/10/2017 12:00:00 AM	ADDRESS	34.23154	-118.5691	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29585	11041-10000-11402	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	34.04538	-118.26389	OUTDOOR SIGN LIGHTING ON THE NORTH AND SOUTH SIDES OF EXISTING HIGH-RISE BUILDING.  (HOTEL FIGUEROA) SIGNS ARE EXTERNALLY ILLUMINATED WITH 1500W METAL HALIDE  LAMPSPLAN CHK IS FOR TITLE 24;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29586	15041-20000-30200	201 N FIGUEROA ST 14th floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI to existing high rise commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 5,870.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29587	15041-10000-20233	4975 W SUNSET BLVD	90027	13	147B197   708	5543006024	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.09829	-118.29805	PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE CHURCH TO OFFICE. NEW 1000AMP SERVICE. ALL ELECTRICAL EQUIPMENT ARE NEW.**3/8/16: Fire Alarm Variance is filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29588	16041-20000-26546	8156 N SYLMAR AVE	91402	6	192B149   556	2212006010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.21935	-118.44649	Plan check for PV roof mounted battery backup system. System size: 2.5kW with 12 modules and 12 microinverters and 180Ah battery backup.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29589	18041-10000-28461	740 S BROADWAY	90014	14	127-5A209 107	5144015023	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	05/14/2024 12:00:00 AM	ADDRESS	34.04414	-118.25412	PC FOR POWER AND ENERGY FOR  HIGH-RISE RETROFIT ORDINANCE  (12 STORY) WITH GENERATOR.   SCOPE INCLUDES TWO NEW 1000A  277/480V 3 PH. SERVICES, ONE OF THE SERVICE IS SUPPLYING FIRE PUMP. NEW LIGHTING EQUIPMENT AND CIRUCITS, NEW 100HP FIRE PUMP, ETC. TOTAL AFFECTED AREA  66000 SQ.F.  CINEMA SWITCHGEAR EXISTING TO REMAIN RE-FED FROM THE NEW 1000 AMP SERVICE.  ((B#18016-10000-06163))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29590	12041-10000-27226	362 E 1ST ST	90012	9	129A215    54	5161017033	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	ADDRESS	34.04913	-118.23932	CHANGE OF USE FROM HEALTH SPA TO RESTAURANT (2172 S.F) ON THE FIRST FLOOR OF  EXISTING 2-STORY BUILDING  , ADD OPEN OUTDOOR DINING AREA. NO ALCOHOL BEVERAGES, MAX. 49 OCCUPANT LOAD, MAX. 4 EMPLOYEES PER SHIFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29591	11041-10000-17989	8375 N LAUREL CANYON BLVD	91352	6	192B165   307	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			PC Info Complete	02/01/2012 12:00:00 AM	ADDRESS	34.22391	-118.39926	TI TO AN EXISTING RESTAURANT WITH 900A OF ADDITIONAL LOAD, 3 NEW PANELS AND NEW CIRCUITS.  PLAN CHECK IS FOR ENERGY AND POWER.NOTE THAT DWP MAY CHANGE TO A LARGER TRANSFORMER; THIS PALN REVIEW DID NOT INCLUDE A NEW SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29592	16041-20001-13123	20324 W AETNA ST	91367	3	177B113   187	2149009003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM			PC Approved	04/25/2016 12:00:00 AM	ADDRESS	34.17868	-118.57628	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.2 kWac and consists of (2) inverters, (38) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29593	15041-30000-44032	5550 W MANCHESTER AVE	90045	11	096B173   121	4126001010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	33.95972	-118.37813	Plan check for power only.  Service upgrade to 800 A.  Combining seperate services for each tenant into one service for the whole building.  All six existing subpanels to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29594	16041-10001-16027	5656 N BELLINGHAM AVE	91607	2	174B165   511	2340025006	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Closed	06/19/2018 12:00:00 AM	ADDRESS	34.17384	-118.39856	Changes to approved set.  Addition of two new modules and changes to layout of rooftop array.         PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP.   TOTAL SYSTEM SIZE IS  7.50KWdc / 7.125KWac. (25) AC MODULES- LG MONOX LG300A1C-B3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29595	15041-10000-34862	400 N KINGSLEY DR	90004	13	138B193   153	5521023015	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Expired	11/15/2017 12:00:00 AM	ADDRESS	34.07795	-118.30336	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29596	17041-10000-20190	6820 N RESEDA BLVD	91335	3	183B125   874	2125010019	[Q]C2-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.19451	-118.53584	Title 24 plan check.  Remove HID fixtures and replace with new LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29597	17041-20000-42961	921 N HIGHLAND AVE	90038	4	144B185  1094	5532012042	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.08774	-118.33877	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 547 sq. ft.Note: Building permit has been issued under 17016-10000-15869	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29598	11041-20000-11842	2354 S COTNER AVE	90064	5	123B153    99	4322023019	M2-1	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Expired	07/05/2013 12:00:00 AM	ADDRESS	34.03653	-118.43678	Plan check for new 800A service and swithboard to an existing building. Existing 400A service to be removed. No new load added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29599	16041-20000-37501	1244 W 39TH ST	90037	8	117B197   814	5037007001	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			10/21/2016 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Closed	01/24/2020 12:00:00 AM	ADDRESS	34.01515	-118.29876	PLANCHECK FOR POWER AND ENERGY. 13 UNIT APARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29600	16041-10000-01584	2029 CENTURY PARK EAST 450	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	PIN	34.05957272	-118.4137405	T-24, TENANT IMPROMENT TO (E) OFFICE. CONSTRUCT NEW NONBEARING PARTITION, CEILING, MILLWORK, FINISHES. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ FT 1440	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29601	11041-10000-18341	1777 E OLYMPIC BLVD	90021	14	121-5A215  31	5146010014	M3-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	05/22/2012 12:00:00 AM	ADDRESS	34.02808	-118.23934	REMODELING OF A YOSHINOYA RESTAURANTFIRST TENANT IN THE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29602	11041-20000-10675	555 S FLOWER ST 45TH FLR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM			PC Approved	05/24/2011 12:00:00 AM	ADDRESS	34.05048	-118.25755	PLAN CHECK T24 ENERGY LIGHTING AND EMERGENCY TI ON 45TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29603	19041-20000-15686	4379 N WINNETKA AVE	91364	3	165B113   106	2174027013	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.15022	-118.57185	PV1.  Install 15.87 kW DC / 11.4 kW AC roof mounted grid tied PV system.  (46) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29604	17041-10000-33180	6540 W SUNSET BLVD	90028	13	147A187   165	5547026024	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.09782	-118.33292	PC FOR OFFICE TI IN (E) A TWO STORY BLDG. TOTAL CONNECTED LOAD <400A  TOTAL AFFECTED AREA 6696 SQ.FTSCOPE INCLUDES NEW PANELS, CIRCUITS, LIGHTS AND EQUIPMEMNT. B#17016-20000-09488	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29605	14041-20000-15311	16762 W LONDELIUS ST	91343	12	195B137   737	2688029073	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Expired	07/26/2016 12:00:00 AM	ADDRESS	34.22927	-118.49805	PV1.  Install 8.925 kW roof-mounted, utility-interactive PV system.  (2) transformerless inverters with DC converters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29606	12041-10002-16683	333 S ALAMEDA ST	90013	9	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.04448	-118.23824	MODIFICATIONS TO APPROVED SET OF PLANS (12041-10000-16683)PANEL BAL-3 WILL SUPPLY  PANEL LCP5 AND SUB PANEL MASTER CTRL PNL.; ANEW PANEL BEFORE LCP3 WITH A MASTER CTRL PNL AND A PANEL BEFORE PANEL LCP1.NOTE THAT SCOPE OF WORK HAS CHANGED SUCH THAT PLAN CHK CAN BE DONE AT THE COUNTER(((((((((((((full plan check per owners request, title 24 and emergency lighting, 5 new panel , arcade, restaurant, bowling. must use area catagory. plann check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29607	14041-20000-09026	3183 W WILSHIRE BLVD 1ST FLOOR	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.06196	-118.29111	TI for fitness room, laundry room, break room, and yoga room on first floor of existing highrise apartment building.  Plan check for Title 24 for changes to lighting system.  Yoga and break rooms to have only like-for-like replacement or relocation of existing fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29608	16041-10000-18180	515 S FLOWER ST Floors 3-4	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC FOR ENERGY ONLY. T.I. to 3rd and 4th floors of (e) office building at North Tower; SCOPE OF ENERGY work consisting of 42892 SQ FT. B# 16041-10000-18168.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29609	19041-10000-50770	2581 E CHAUCER ST BUILDING 4	90065	1	145-5A217 517	5445031***	[Q]CM-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	09/03/2020 12:00:00 AM		Permit Finaled	07/28/2021 12:00:00 AM	PIN	34.0949861	-118.23281575	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A SERVICE OF 400 AMPS, 120/208 V, 3-PHASE 4W FOR BUILDING 4. TOTAL AFFECTED AREA: 5662 SQ FTALL 5 BUILDINGS ARE CONNECTED TO 1 SERVICE SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29610	18041-10000-17380	20524 W LASSEN ST	91311	12	201B109   128	2748005048	(T)(Q)CM-1L, (T)(Q)CM-1LD, (T)(Q)M1-1, (T)(Q)M1-1D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	06/25/2020 12:00:00 AM		Permit Finaled	12/21/2023 12:00:00 AM	ADDRESS	34.24972	-118.58132	PC FOR POWER AND ENERGY FOR A NEW4-STORY HOTEL, 124 GUEST ROOM, MARRIOTT RESIDENCE INN HOTEL. SCOPE INCLUDE NEW SERVIVE (2500A, 120/208), PANELS, EQUIPMENT AND LIGHTING. TOTAL AFFECTED AREA FOR INDOOR IS  87109  SQ.FT. AND OUTDOOR: 38,930.B# 18010-10000-02097	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29611	11041-20000-23899	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/08/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Closed	02/28/2012 12:00:00 AM	ADDRESS	34.05715	-118.41482	energy plan check ballroom emergency lighting existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29612	15041-30001-39695	10574 N DES MOINES AVE	91326	12	207B117   336	2728005005	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.26266	-118.55575	Expedite fees only.    Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect new inverter and modules with existing PV system.  Total system size = 6.7 kWac (3 kWac new).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29613	18041-10000-41071	2335 S WALL ST	90011	9	120A207    44	5127013027	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.02455	-118.26354	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29614	16041-10000-20564	17825 W BAHAMA ST	91325	12	195B129   179	2768030003	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.23285	-118.52233	PV1, ROOF MOUNTED SOLAR SYSTEM USING AC MODULES. (18) SUNPOWER SPR-E20-327AND (18) SPR-E20-327. TOTAL SYSTEM SIZE IS  5.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29615	18041-10000-32781	4751 W FOUNTAIN AVE	90029	13	147B197  1061	5543016019	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.09563	-118.29308	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29616	10041-30000-00689	104 S ROBERTSON BLVD	90048	5	138B169   373	4334005002	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	01/27/2010 12:00:00 AM		Permit Finaled	02/19/2010 12:00:00 AM	ADDRESS	34.07505	-118.3836	TI - retail / clothing store - Permit is for new ckts on existing ckt.  P/C is for Energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29617	17041-20000-45345	941 W 35TH ST	90089	9	120A201    44	5039012030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Closed	05/22/2018 12:00:00 AM	PIN	34.02328797	-118.28705198	Replacement of receptacles and associated wiring in North Complex Residence Halls at USC.  Associated electrical infrastructure upgrade approved under 17041-20000-00778.Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29618	15041-10000-41418	165 W 57TH ST	90037	9	108B201  1026	5101028001	R2-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	01/16/2016 12:00:00 AM	ADDRESS	33.99069	-118.27625	PV1, INSTALL 2.12 KW DC ROOF-MOUNTED SOLAR ARAY ON A SINGLE FAMILY HOUSE.(8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29619	14041-20000-11114	1610 W 7TH ST	90017	1	132A205   366	5142016001	C2-2	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.05397	-118.27168	T.I. to existing building on the first floor and second floors.  Install general/emergency lighting.  New load less than 400A.  Plan for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29620	16041-10000-24624	2664 N GRIFFITH PARK BLVD	90039	4	150A205    63	5434037020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	PIN	34.10676975	-118.27192339	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1202 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29621	10041-10000-19173	2700 W COLORADO BLVD # 103	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	ADDRESS	34.14248	-118.22438	CHANGE OF USE FROM RETAIL TO SKIN CARE IN (E) COVER MALLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29622	12041-10000-19456	3056 N DURAND DR	90068	4	157-5A189 220	5582011015	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2012 12:00:00 AM			PC Approved	09/25/2012 12:00:00 AM	ADDRESS	34.12478	-118.32365	PLAN CHECK ONLY. 14.5KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM. PERMIT OBTAINED UNDER #10041-10000-10773.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29623	16041-10000-33717	2032 E MARENGO ST	90033	14	132A225   155	5201014023	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM			Corrections Issued	09/22/2016 12:00:00 AM	ADDRESS	34.05638	-118.20741	PC for power and energy.  TI to an existing medical office. Scope of work is being done for a medical dispenser, no surgical operation or patient care invloved. Installig new lighting and power. Total sqft = 363.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29624	14041-20000-17595	1902 E MARENGO ST	90033	14	132A223    33	5201016003	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.05756	-118.21009	TENANT IMPROVEMENT AND CHANGE OF USE FROM MEDICAL OFFICES TO PHARMACY @ 2ND FLOOR OF (E) COMMERCIAL BLDG. new lighting. PC for T24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29625	19041-10000-44229	916 N WESTERN AVE Suite 928	90029	15	021B193   193	7445011015	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	08/16/2021 12:00:00 AM		Issued	08/16/2021 12:00:00 AM	ADDRESS	34.08674	-118.30896	FULL PC FOR A CHANGE OF USE, SCOPE INCLUDES AN EXSTING 600A SERVICE, NOTE TOTAL CONNECTED NEW LOAD IS OVER 400A. SCOPE INCLUDES 3 NEW PANELS AND SQUARE FOOTAGE IS 3739 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29626	16041-10000-25791	21263 W ERWIN ST	91367	3	177B105    20	2149001029	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.18302	-118.59459	PC FOR ENERGY ONLY. T.I  IN  LOBBY, OFFICE RMS,  RECEPTION , AND WAITINGAREA OF KAISER PERMANENTE BUILDING. NOT MEDICAL AREA.  (TOTAL AREA 1314.5 SQ FT.B# 16016-10000-16469	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29627	15041-20000-38338	400 S HOPE ST 10th Floor	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	TI to existing high rise commerical building (10th floor). Plan check for energy only. Adding new lighting including emergency. Total sqft. 16,987.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29628	17041-20000-34457	14323 W JOY DR	91331	6	198B153  1031	2644027243	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.2416	-118.44535	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29629	15041-20000-28775	11210 W SARDIS AVE 1-25	90064	5	123B157  1225	4251002023	R3-1	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.02959	-118.43029	Plan check for power and energy for 25 units appartment 5 story. Total common area: 24,404 sqft.2008 Title 24 standard is being use. Note: --Fire alarm Variance has been filed 09-01-2015--Fees for 2 switch board sections(1000A and 600A) shall be added, applicant has a pre-cut check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29630	16041-20000-36454	5963 N VAN NUYS BLVD	91401	4	177A151    99	2244001007	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.17916	-118.449	Plan check for Title 24 only. Project site is the parking lot of an existing commercial building. Project scope is parking lot lighting. Total lighting area = 12,800 sq. ft.Note: Building application has been generated under 16020-20000-03066	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29631	19041-10000-46069	870 N WESTERN AVE	90732	15	021B193   193	7445011015	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	02/04/2020 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	33.75055	-118.30889	TI IN A NEW MEDICAL OFFICE. INSTALLING NEW PANELS, X-RAY EQUIPMENT, GENERAL LOADS, LIGHTS ETC. PLAN CHECK FOR POWER & ENERGY. AFFECTED AREA: 7377SFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29632	17041-10000-20749	1575 N GOWER ST 150	90028	13	148-5A189 330	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	PC FOR TI FOR AN OFFICE (HIGH RISE) TITLE- 24 ENERGY ONLY.  NEW LIGHTS RECEPTACLES CIRCUITS AND ONE PANEL. TOTAL AFFECTED AREA 4426 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29633	11041-10000-00379	125 E ANAHEIM ST # L	90744	15	030B205   279	7423003036	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			Corrections Issued	01/07/2011 12:00:00 AM	ADDRESS	33.78019	-118.26143	INTERIOR TI TO EXISTING TAKE-OUT RESTAURANT (DONUT SHOP CHANGE TO FROZEN YOGURT SHOP).  NO COOKING EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29634	17041-10000-07994	437 S HILL ST	90013	14	130-5A211 148	5149027013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Closed	09/03/2019 12:00:00 AM	ADDRESS	34.0495	-118.2514	PC for temporaty power with 800A 480/277 V Service, crane motor, man lift, 6 panels, four 75 KVA transformers. The site is located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29635	17041-10000-39749	260 S MAIN ST 1ST FL	90012	14	129A213    26	5161026908	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.04961	-118.24558	NEW RESTROOMS AND LUMINAIRES IN EXISTING RETAIL/ OFFICE  SPACE USING EXISTING BRANCH CIRCUITSPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29636	19041-20000-30224	12021 W VALLEYHEART DR	91604	2	165B165   873	2368016036	[Q]R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Apartment			08/05/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Issued	08/05/2019 12:00:00 AM	ADDRESS	34.1474	-118.39266	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW 4 STORY 21- UNIT APARTMENT BUILDING. SCOPE OF WORK CONSISTS OF 111 FA DEVICES AND A FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29637	18041-10000-48399	6725 N KESTER AVE	91405	6	180B149  1059	2235007037	[Q]CR-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.19255	-118.45774	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29638	13041-10000-26257	18241 W SYLVAN ST	91335	3	177B125    28	2124018050	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.18545	-118.53093	$0 PERMIT FEE DUE TO 2012 SENATE BILL 1222. PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200A MAIN IN A 2-STORY HOUSE. WORK IS DONE ON A CENTRAL INVERTER SYSTEM, STANDARD PLAN. SYSTEM SIZE IS 10.5 KWDC WITH (42) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29639	19041-20000-17834	11150 W OLYMPIC BLVD ste 810	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM			PC Approved	05/13/2019 12:00:00 AM	ADDRESS	34.03956	-118.43857	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29640	11041-20000-18762	9150 W ORIOLE WAY	90069	5	147B169   846	5560006013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.0964	-118.38915	New single family residence.  Full plan checkNOTE TO PLAN CHECKER:  THE NEW 600AMP SERVICE WAS NOT ADDED TO FEES.  PLEASE ADD DURING THE PLAN CHECK PROCESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29641	16041-10000-11214	514 S SPRING ST	90013	14	129A211   153	5149036907	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.04695	-118.24984	PC FOR INSTALLATION OF EMERGENCY LIGHTING FIXTURES. FOOT CANDLE CALC PROVIDED FOR THEATER. ALL FIXTURES BATTERY BACKUP CONNECTED TO LOCAL LIGHTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29642	14041-20001-25754	7809 W ELLENBOGEN ST	91040	7	210B193   273	2552013032	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.27186	-118.30326	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29643	15041-20000-02384	13608 N SIMSHAW AVE	91342	7	228B161   692	2580012029	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.31925	-118.41259	Roof mounted PV system with microinverter (enphase M250-60-2LL).  Total system size 3.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29644	11041-10000-17926	900 N ALAMEDA ST LOWER LEV	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Public Safety Only			08/23/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.05855	-118.23671	PRE-ACTION SYSTEM WITH FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29645	14041-20000-08744	5361 E HUNTINGTON DR NORTH 1-8	90032	14	145-5A237 198	5309017026	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Apartment			04/02/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.09178	-118.16389	Installation of new fire alarm control panel in apartment structure. Replacement of all existing devices. Non-central station monitoring.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29646	18041-20000-43383	10866 W WILSHIRE BLVD Suite 370	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	34.05907	-118.442	Plan check for Title 24 only. Project site is an existing commercial tenant space is a high rise building. Project scope is a tenant improvement. Total lighting area = 1,070 sq. ft.Note: Building permit has been issued under 18016-10000-29005	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29647	15041-10003-10402	304 W ORD ST	90012	1	133-5A215 144	5408015003	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.06005	-118.23881	"Revision on approved set under Delta-3. Show ""Time clock, Override switch, and control diagram"". This is PC only, permit under 15041-10000-10402 <<ALTERATIONS TO AN EXISTING RESTAURANT SPACE. PC FOR TITLE 24 ONLY. SQ. FT. 930>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29648	19041-10000-22309	6201 W HOLLYWOOD BLVD	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC for T24 for a ti. Scope of work includes new lighting , recepatcles, and controls. Total affected area is 1250 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29649	11041-10001-16708	4556 W COUNCIL ST	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.07451	-118.30959	NEW 800A SERVICE AND CIRCUITS FOR A GROUP OF 6 COMMERCIAL BUILDINGS.  MAIN SERVICE IS IN BUILDING 4558 W. COUNCIL ST.  OTHER BUILDINGS (143 N. WESTERN AVE,    147 N. WESTERN AVE,      149 N. WESTERN AVE,    151 N. WESTERN AVE.) WILL BE ON SUPPLEMENTAL PERMITS TO THIS.     THIS APPLICATION IS FOR 4556 W. COUNCIL AVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29650	10041-10000-24950	2301 W BELLEVUE AVE 10TH FL	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.07417	-118.26931	CHANGE OF USE/OCCUPANCY ON 10TH FLOOR FROM OFFICE  (4,137 SQ FT) TO DORMITORY WITH ADDITIONAL OF 4 GUEST ROOMS FOR A TOTAL OF 20 FOR THE CHURCH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29651	13041-20000-33135	530 N PALISADES DR	90272	11	129B117   107	4419015025	(Q)C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.04525	-118.55178	Change to lighting to an existing bank.  Load is less 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29652	16041-10008-38001	4061-4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	33.99055	-118.44379	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 7 ONLY. CHANGE OF HOUSE METER NAMES.<<<PC FOR POWER AND ENERGY FOR A MIXED USED BUILDING (49 UNITS)SCOPE INCLUDES NEW SERVICE (4000A /480V)B#16010-10000-04167>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29653	17041-10000-30367	1325 S WYCLIFF AVE	90732	15	012B193   133	7560015007	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	33.73181	-118.31297	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 2.24KW AC  2.56KW DCSCOPE INCLUDES 8 MODULES WITH 8 MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29654	17041-10000-11974	3530 W OLYMPIC BLVD	90019	10	129B189   269	5081018025	C2-1-O	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.0523	-118.31598	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 7150 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29655	12041-10000-07872	840 W 149TH ST	90247	15	072B197    30	6119025900	OS-1XL	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	33.89677	-118.29128	PLAN CHECK POWER FOR NEW LA CITY ROSECRANS SPORTS FIELD LIGHTING. NEW 400A SERVICE AND EQUIPMENT. SITE LOCATED IN METHANE BUFFER ZONE. LIGHT STRUCTURES APPROVED UNDER BUILDING APPLICATION #12020-10000-00587	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29656	13041-10000-32951	11714 W REMINGTON ST	91342	7	213B169   451	2531023026	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.28146	-118.38798	PV1, Install  7.75 kw DC roof-mounted solar array, interconnect with service panel.(2)Transformerless inverters: SOLAREDGE SE3800-US. (31) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29657	14041-20000-08982	4111 N MONET AVE	91364	3	165A105   225	2173006019	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.14463	-118.59951	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.7KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29658	15041-20000-34959	15910 W VENTURA BLVD Suite 1801	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.15561	-118.47969	Plan check for Title 24 only. Project site is an existing commercial, high-rise building (18th Floor). Project scope is a tenant improvement. Total lighting area =6,990 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29659	18041-20000-22250	13741 W MULHOLLAND DR	90210	4	159B157   172	2272030003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM			Reviewed by Supervisor	07/03/2018 12:00:00 AM	ADDRESS	34.13224	-118.43242	Plan check for Power only in Single Family Dwelling for 600A ServicePlan check only. Electrical Permit pulled under Building application number: 16010-20000-04614	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29660	15041-10001-28779	7036 N RANCHITO AVE	91405	2	183B153   460	2216031022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM			Reviewed by Supervisor	09/16/2015 12:00:00 AM	ADDRESS	34.19867	-118.43552	PV 1, roof mouted solar system for a residential site. (36) modules, (2) inverters: 11kw. (1) load center: 125 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29661	13041-10000-22341	12000 W IDAHO AVE 1-8	90025	11	126B145   893	4259003006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			08/16/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.03918	-118.46049	PLAN CHECK  FIRE ALARM SYSTEM FOR  APARTMENT 34 UNIT 4 STORY FULLY SPRINKLERED BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29662	12041-20000-11719	15222 W VENTURA BLVD	91403	5	168B145   995	2276007058	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.15331	-118.46466	New Fire Alarm System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29663	16041-10001-04045	7330 S WESTLAWN AVE	90045	11	102B161    91	4110028024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM			PC Approved	02/29/2016 12:00:00 AM	ADDRESS	33.9741	-118.41104	2/29/16: Changes to approved set on rooftop modules orientation, module count, and module type to be (23) Triex U280. Permit under 16041-10000-04045. Zero fees ($0) per California Bill 1222**PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (22) MODULES (1) 3.6 (1) 3.0 INVERTER. TOTAL SYSTEM SIZE IS 6.6KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29664	19041-10000-06212	12000 W FOOTHILL BLVD	91342	7	210B165   539	2532012043	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Arleta - Pacoima, Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Pacoima		1041.08	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.27667	-118.39775	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29665	14041-10000-09258	1226 S SAN PEDRO ST	90015	14	123A211    39	5132012058	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.03293	-118.25365	Remove HID light fixtures and replace with new fluorescent fixtures. Total area 308 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29666	11041-10000-01447	111 E UNIVERSAL HOLLYWOOD DR # 1700-10UCP	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVEMENTS IN OFFICE SPACESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29667	15041-20000-02171	13220 N WHISTLER AVE	91344	12	225B133   237	2602003006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	PIN	34.30956484	-118.50662169	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING MICROINVERTER SYSTEM. ENPHASE M215. USING TOTAL OF 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29668	14041-10000-05692	3821 N MONTEREY ROAD	90032	14	145-5A229 288	5302028034	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			Reviewed by Supervisor	03/12/2014 12:00:00 AM	ADDRESS	34.09125	-118.18834	PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(10) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER:  POWER-ONE AURORA PVI-3.0-OTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29669	17041-10000-02271	16840 W VANOWEN ST	91406	6	180B133    13	2231019022	C2-1VL-RIO, R1-1-RIO, R1P-1VL-RIO, RD2-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Issued	01/24/2017 12:00:00 AM	ADDRESS	34.19373	-118.50043	PC for Tile 24 only. Remove exterior HID fixtures and replace with new LED fixtures. Area: 26,800..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29670	14041-10001-12462	700 WORLD WAY TERMINAL 7-TempPower	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	33.94286	-118.39982	CHANGES TO PERMITTED SET OF PLANS; DIST PANELS  T-DPC AND  P3 LODS WERE REDUCED delta 5 changes (((((((Temporary power for 4 MCPs (1-4) and corresponding temporary dist. panels PDP-A3 and PDP-B8 by contractor Dynalectric. Feeders to the PDP panels were under application 14041-10000-12456. See 13041-10001-10268 for plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29671	14041-10000-32920	2629 N MAIN ST	90031	1	136-5A221 388	5210004025	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	PIN	34.06625898	-118.21439418	Plan check for a roof-mounted PV system. System size is 3.6 kWac and consists of (16) modules and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29672	19041-10000-27695	1400 S BROADWAY	90015	14	124-5A207 215	5133008007	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.03532	-118.26243	PC FOR NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 24 FA DEVICES AND 1 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29673	12041-20000-15056	3425 S MOTOR AVE	90034	5	120B161   346	4314017004	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			06/28/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.02711	-118.40945	115 units apartments with reatail variance for fire alarm on hand	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29674	18041-10000-42449	4950 W SUNSET BLVD	90027	13	147B197   813	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	ADDRESS	34.09786	-118.29745	PLAN CHECK FOR BLOOM ENERGY (300KVA) FUEL CELL SYSTEM CONNECTING TO EXISTING DISTRIBUTION EQUIPMENT - CONNECTION CONSIST OF UPGRADING 600A PANEL TO 1200A, ALL BREAKERS ARE 100% RATED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29675	16041-20001-19703	3711 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.01909	-118.35577	5.2.2017 - Plan check for modifications to approved set. Building out mezzanine floor with offices. Additional branch circuit loads. Adding elevator. Floor plan layout and lighting design on first floor were changed. Update T24 documents. Adding 7 new lighting fixture types. New area: 1,528sqft.=======PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29676	18041-20001-05802	20141 W WELLS DR	91364	3	171B113   458	2166009006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	06/28/2018 12:00:00 AM	ADDRESS	34.16189	-118.57156	Revisions to approved set.  Reduction in system size by (10) modules.  Total system size is now 11.8 kW.  Slight associated changes to equipment ratings/conductor sizing.  (((PV1.  Install 14.7 kW roof mounted grid tied PV system.  (50) modules with microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29677	19041-10000-16105	240 W VENICE BLVD	90015	14	124-5A207 216	5134022903	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	ADDRESS	34.03533	-118.26598	PC for TI T24 only,  new lounge area to an exisiting rooftop. Affected area is 1528 SQFT both indoor and outdoor. Highrise building((ATTN:  GARO  TELMISUPPLEMENTAL TO PERMIT APPLICATION# 19016-10000-04008  FOR RECHECK DUE TO CHANGE IN WORK SCOPE))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29678	17041-10001-02345	6656 W HOLLYWOOD BLVD	90028	13	148-5A185 137	5547014010	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.10134	-118.33536	"Changes to an approved set of plans. All changes are clouded under Delta 3. Changees include removing/replacing lighting fixtures, revising title 24 calculations, adding a 75KVA transformer, adding new receptacles, a new 400A subpanel, and revising single line diagram. ""COMPLY WITH DEPARTMENT ORDER effective date 01/28/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29679	14041-10002-03293	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	(((7/11/2014  Addition of lighting to outdoor porte-cochere. Total area = 41,080 sq. ft. of illuminated hardscape)))This a high rise 12 story office building, converte to a hotel , 231 guest rooms. power, lighting , indoor and out door title 24, fire alarm deffered, deisel fire pump.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29680	18041-20004-19238	6160 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM			PC Approved	10/25/2019 12:00:00 AM	ADDRESS	34.18234	-118.39628	Revisions to approved plans.  Changes to medium voltage loop distribution overcurrent protection ratings to address coordination, updates to SLD and site plans to reflect architectural changes on buildings A, B, and BA, fixture schedule revisions, etc.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29681	18041-20001-14395	2189 E WHITTIER BLVD	90023	14	124-5A221 121	5183021023	R3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.03614	-118.21937	8/8/2018changes to an approved set of plans.  changes to include 75KVA transformer and downsize main breaker from distribution board to 400 amps. plan check for power only.(((Plan check for power and energy in existing space T.I. coin laundry.  Install 600A equipment.  Total area: 3,223 sq ft.COMPLY WITH DEPARTMENT ORDER effective date 09/15/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.B# 18016-20000-11498)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29682	13041-10000-01148	860 N WESTERN AVE	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM			PC Approved	01/16/2013 12:00:00 AM	ADDRESS	33.75045	-118.30891	CHANGE OF USE FROM RETAIL TO CREDIT UNIONPLAN CHK IS FOR TITLE 24 ; PERMIT WAS OBTAINED ON 12041-40000-26710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29683	19041-10001-22463	10243 N BOTHWELL ROAD	91324	12	204B117   215	2726009041	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.25667	-118.56182	Changes to approved set for relocation of modules. Original Scope((Plan check for a PV1 5KW AC / 6.7KW DC roofmounted system with (1) inverter, (22) modules, and optimizer interconnecting through the service panel.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29684	12041-10000-14640	7644 N FARRALONE AVE	91304	3	186B101    34	2012021072	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.20945	-118.61016	Plan check for power and energy. 91 occupants. 2720 sqft.New 600A panelBUILDING PERMIT FOR A LIBRARY ADDITION TO AN EXISTING CLASSROOM BUILDING ON THE FAITH BAPTIST CHURCH CAMPUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29685	16041-10000-45025	10819 W PENROSE ST	91352	7	195B177   178	2544026029	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.23246	-118.36555	Plan check for PV roof mounted system. System size: 8.6kW with 40 modules and 40 microinverters.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29686	14041-20000-05191	12695 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97727	-118.41529	((EXPEDITE FEES)))Roof mounted PV system with 3KW AC USING TRANFORMERLESS INVERTER. THIS IS PART OF A SERIES SET OF SUBMITTALS. THIS PV SYSTEM TO INTERCONNECT TO COMMON SERVICE. THIS IS PROJECT 3 OF 3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29687	17041-10000-31288	355 S GRAND AVE LEVEL 4	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR T24 ONLY, TI ON EXISTING  OFFICE,  AS WELL AS ADD CIRCUITRY WITH TOTAL LOAD < 270 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29688	17041-20000-43976	4834 N ARCOLA AVE	91601	4	168B177   382	2420014020	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.15868	-118.35484	pv1install roof mounted pv system sized 6.6kw with battery back up inteconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29689	12041-20000-26705	6709 N INDEPENDENCE AVE	91303	3	180B105    31	2148029018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.19249	-118.59082	Electrical system upgrade to install new generator and new panels to supply existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29690	11041-20000-18374	555 W 5TH ST 21st floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I.  Remodel of the light fixtures on the 21st floor of a high rise ofice building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29691	14041-10001-31310	12224 W TRUESDALE ST	91352	6	198B165    37	2629008005	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM			PC Approved	02/06/2015 12:00:00 AM	ADDRESS	34.24038	-118.39922	Changes to approved set to reflect as-built field conditions.  New main service panel with derated breaker.  Zero fees charged due to senate bill.*****Previous Work Description*****Installation of new roof mounted solar PV array.  Total system size = 7.2 kWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29692	19041-10000-47174	12812 N JOLETTE AVE	91344	12	222B129   194	2602012019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.303	-118.51258	PV1, New solar system using microinverters. (21) modules and microinverters. Total system size 6.09 kwac/ 7.56 kwdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29693	12041-10000-12806	10153 N CREBS AVE	91324	12	204B121   318	2729009005	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.2546	-118.54366	Plan check 8.16KW roof mounted Enphase M215 mircoinverters photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29694	13041-10000-27153	11125 N DULCET AVE	91326	12	210B121   236	2717007020	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.27269	-118.54054	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH  MAIN; WORK DONE ON A non-STANDARD PLAN. 4 TOTAL STRINGS; LOAD CENTER WILL BE USED; DC UNGROUNDED; SYSTEM SIZE IS 8.5KW DC WITH (34) MODULES: TRINA #TSM-250PA05.18(2)POWER-ONE #PVI-3600-OUTD-S-US, PVI-5000-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29695	11041-10000-12582	9414 W VENICE BLVD 1-6	90232	5	120B165   817	4206028019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM			PC Approved	06/17/2011 12:00:00 AM	ADDRESS	34.02508	-118.39513	title 24 for on site no super graphic sign.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29696	19041-20000-06584	1038 N LARKER AVE	90042	14	157-5A235 101	5716030044	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.12541	-118.1705	NEW 13.5 KWH ESS FOR EXISTING SFD, INCLUDES 5KW POWERWALL AND NEW 200A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29697	18041-10000-09769	636 E 41ST PL	90011	9	114A207    87	5115003002	R2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.00809	-118.26455	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 3.0KVA CONSISTING OF 1 CENTRAL INVERTER (SOLAREDGE SE3000H-US) WITH 13 MODULES WITH POWER OPTIMIZERS (P370).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29698	16041-20000-44580	14926 W ALTATA DR	90272	11	123B129   722	4411024041	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM			PC Info Complete	03/20/2017 12:00:00 AM	ADDRESS	34.03127	-118.52097	New two-story single family dwelling with attached garage over basement.  1000A 120/240V 1-ph service.  Plan check for power.This is Plan check only, Permit for electrical was paid for under Combination Permit 14010-30000-00665	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29699	14041-10000-02023	22727 W MICHALE ST	91304	12	195B097     4	2004015020	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			Corrections Issued	01/23/2014 12:00:00 AM	ADDRESS	34.22692	-118.62233	New rooftop PV system for an existing single family dwelling.  System uses Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29700	17041-20000-15657	19163 W OXNARD ST	91356	3	177B121   607	2156001023	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.17943	-118.55121	pv1install roof mounted pv system sized 6.6kw interconnected with msp.  standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29701	17041-10000-36500	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.12626	-118.21412	FROM THREE EXISTING SWBDS, PROVIDE ELECTRICAL POWER TO ATHLETIC LIGHTING, IDF  ROOM, AND POOL EQUIPMENT BUILDING. OTHER BUILDINGS INCLUDE CULLEY GYM, DEMANDEL POOL DECK, AND MCKINNON TENNIS FACILITIES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29702	17041-20000-12971	9513 N ENCINO AVE	91325	12	201B129   435	2755009049	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.24378	-118.51576	pv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29703	19041-20000-42234	9100 N TELFAIR AVE	91352	6	195B165    15	2631004010	(T)(Q)RD1.5-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM			PC Approved	11/25/2020 12:00:00 AM	ADDRESS	34.23467	-118.39477	Plan check only, for power and energy, 200 Amp Service for each service(typeical for 4 service and 1 commom service). outdoor lighting. Total outdoor commom area: 11,368 sq ft. Plan check onlyNote: Plan submitted per applicant requestPermit shall be pulled under building applications as Combination permitWork Description per Building Permit: Single family dwelling small lot sub-division	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29704	15041-20000-41527	16633 W VENTURA BLVD #1320	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for Title 24 only for existing office space T.I. Total area: 3,228 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29705	12041-20000-03026	2910 W BEVERLY BLVD	90057	13	138A201   357	5155004023	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.07099	-118.28068	fire alarm replacement low rise building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29706	18041-10003-14610	3260 S CLUB DR	90064	5	123B165   698	4316030025	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.0328	-118.40233	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES REVISION TO AIC (10KAIC) RATING TO REFLECT FIELD INSTALLATION ( WITH FUSE LET-THROUGH). THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29707	18041-20000-12550	12955 W BLYTHE ST	91605	2	189B161   617	2303018028	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.21383	-118.41618	Plan check for PV roof mounted system on SFD, System size: 18kW with 50 AC modules connected to MSP 225A Panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29708	19041-10001-09100	14987 W ORO GRANDE ST	91342	7	219B149   512	2604033009	RE9-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM			PC Approved	03/22/2019 12:00:00 AM	ADDRESS	34.29647	-118.45801	expedite supp for PV.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29709	13041-20000-32049	6407 N VANALDEN AVE	91335	3	180B121   571	2128031013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.18699	-118.54925	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 28 MODULES. USING ENPHASE M215. MICROINVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29710	16041-10000-24753	8886 W VENICE BLVD	90034	10	123B169  1455	4312015005	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	02/25/2017 12:00:00 AM	ADDRESS	34.02965	-118.38717	PC for energy only to an existing commercial bulding. Change of use from werehouse to retail furniture and tenant improvement. Adding new lighting, new panels, and power. Newly connected load is less than 400 amps. Total sqft = 10425 - energy calc using tailored method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29711	14041-20000-08402	555 S IRVING BLVD	90020	4	135B189   837	5504007012	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.06383	-118.31874	SFD, Roof mounted PV system 6.21KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29712	14041-20000-35208	6016 N FALLBROOK AVE Suite 102	91367	3	177B097   489	2039017037	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.17974	-118.62314	Plan check for Title 24 energy only. TI to an existing office. New lighting and receptacles. 1625 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29713	16041-20000-06708	4151 W PROSPECT AVE BLDG T	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Refurbishing of busing and adding new circuit breakers to (E) switchgear.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29714	14041-20000-27560	8240 N VANTAGE AVE	91605	2	192B165   583	2309029014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.22088	-118.39756	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.(1) ABB PVI-6000-OUTD-US-Z-A transformerless inverter(26) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29715	15041-10001-11011	444 S SAN VICENTE BLVD 6th Floor	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.07021	-118.37547	09/20/16Changes to an approved set of plans. All changes are made under delta 3. Changes include relocating/adding lighting fixtures and receptacles for office and corridor spaces. PC is for non-invasive procedures(General care areas only). (((((TI TO AN (E) MEDICAL BUILDING, IN THE 6TH FLOOR. PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29716	19041-20000-41376	11869 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	09/26/2021 12:00:00 AM	ADDRESS	34.28585	-118.38981	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29717	19041-10000-07891	11117 W VICTORY BLVD	91606	2	180B173   616	2336001900	OS-1XL	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.18686	-118.3729	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29718	17041-10000-03677	5713 N FIGUEROA ST	90042	1	151-5A229 174	5492001014	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.1099	-118.19254	PC FOR NEW LIGHTING IN NEW ICE CREAM SHOP. PC FOR T24 ENERGY ONLY. PERMIT ISSUED TO COMPLY DEPARTMENT ORDER UNDER CASE #:692465. PERMIT TO EXPIRE WITHIN 30DAYS OF ISSUANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29719	16041-10000-21086	7511 N PONCE AVE	91307	12	186B097   393	2022008018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.2069	-118.62227	NOTE: Permit is $0 due Senate Bill 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.099KWdc / 11.0KWac.(37)MODULES-SUNPOWER SPR-327NE-WHJT-D(1)INVERTER-SMA 5000TL-US-22 & SMA 3800TL-US-22(1)INVERTER-SMA SB6000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29720	18041-20003-00858	7320 N HILLSVIEW CT	91307	12	186B089   513	2027047004	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM			PC Approved	08/28/2018 12:00:00 AM	ADDRESS	34.20479	-118.65146	08/28/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Feeder sizing has been revised as indicated.03/20/2018 Revision to approved set of plans.  Change of locations of equipment, additional subpanel for energy storage systems.  $0.00 plan check fee due to CA Senate Bill 1222(((PV1.  Install roof mounted pv system sized 10kw interconnected with msp with three tesla battery back up.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29721	18041-10000-16910	11460 N HASKELL AVE	91344	12	213B141   159	2662004001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.27884	-118.47571	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.24KWdc / 9.0KWac.(33)MODULES-HANWHA Q. CELLS Q. PEAK G3(1)INVERTER- SMA SUNNYBOY 3.8-US(1)INVERTER-SMA SUNNYBOY 5.0-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29722	10041-10000-12879	12403 W WASHINGTON PL	90066	11	111B157   696	4235018026	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.00	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	09/02/2010 12:00:00 AM	ADDRESS	33.99957	-118.43071	Ti in an existing restaurant. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29723	16041-10000-42850	19780 S PACIFIC GATEWAY DR	90502	15	057B197    48	7351034069	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	33.85141	-118.29512	Plan check Title 24 only in existing space T.I. Office. Total area: 5,505 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29724	17041-20000-19002	23344 W CALIFA ST	91367	3	174B093    57	2041007007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.17656	-118.63578	Plan check for a PV1 roof-mounted PV system. System size is 14.8 kWac and consists of (43) AC modules and (1) load center.$2.23 fee is due to fee cap per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29725	13041-20000-23471	14006 W RIVERSIDE DR SPACE 9082	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	NEW KIOSK IN SMALL TENANT SPACE UNDER ESCALATOR. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29726	11041-10000-22916	6715 S LA TIJERA BLVD	90056	11	102B173   831	4102001028	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	PIN	33.97875212	-118.37120128	T.I. to an existing retail store.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29727	12041-10000-13987	3138 W PICO BLVD	90019	10	129B193  1332	5073008001	C2-1VL	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM			PC Info Complete	07/05/2012 12:00:00 AM	ADDRESS	34.04701	-118.31048	SERVICE UPGRADE TO 800 AMP.  RECONNECT EXISTING LOAD. PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29728	10041-20000-02536	5652 N VINELAND AVE	91601	4	174B173   697	2415005033	C4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM	02/12/2010 12:00:00 AM		Permit Finaled	07/29/2010 12:00:00 AM	ADDRESS	34.17366	-118.36994	Fire Alarm system ( elderly daycare ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29729	16041-20000-17352	6320 N CANOGA AVE 15 Floor	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check Title 24 only in existing space T.I. Total area: 3,032 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29730	12041-20000-05356	8416 N LANKERSHIM BLVD	91352	6	192B169   410	2632022003	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.22326	-118.38758	T.I. to existing building.  Upgrade service to 1200A, install switchboard, panels, branch circuit, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29731	14041-20000-06254	12745 W MATTESON AVE	90066	11	111B153   878	4236017024	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	33.99908	-118.43801	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 1.08KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29732	13041-10000-10063	2756 N WESTSHIRE DR	90068	4	156A191    75	5583015009	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.12066	-118.31974	PV1 STD PLAN CENTRAL INV. 2 STORY. ROOF-MOUNT. 33 hanwha solar hsl60p6-pa-0-240t 240w solar modules, 1 sma sb7000us 240v inverter orion mounting hardware, 2 roof-mount jbox, 1 60a/240vac disconnect, and performance meter. system is negative grounded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29733	17041-10000-03437	13382 W SAYRE ST	91342	7	228B157   948	2511029029	C1-1XL-CPIO	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Issued	02/02/2017 12:00:00 AM	ADDRESS	34.31822	-118.42451	PC for outdoor title 24. Removing HID fixtures and raplaing them with LED ones. Area: 7305 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29734	18041-10000-16450	8856 N WOODMAN AVE	91331	6	195B153   507	2640016011	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.23136	-118.43723	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29735	10041-20000-03663	12001 W VENTURA PL # 404	91604	2	162B165    80	2368002001	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	03/31/2010 12:00:00 AM	ADDRESS	34.14403	-118.39307	TENANT IMPROVEMENT WORK ON  1,240  SQ.FT.  OF THE TOTAL FLOOR AREA.  NEW  WALLS,  POWER,  LIGHTING AND FINISHES. This plan check is only for title 24 energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29736	14041-20000-29254	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHITNG FIXTURES TO EXISTING PANELS.  751 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29737	13041-10001-04656	1250 N NORTH MAIN ST LAX-C	90012	1	135A217   138	5409010032	[Q]M2-1	Central	Central City North			2060.10	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.0641	-118.23218	CHANGES TO APPROVED SET. PLAN CHECK ONLY. DELTA 1 CHANGES ONLY.  ADD 2 WATER HEATER AND 2 LIGHTS IN RESTROOM. PERMIT WILL BE UNDER 13041-10000-04656.New warehouse building. Suite # LAX-C.  Plan check for Power & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29738	16041-20000-25521	10910 W PEACH GROVE ST	91601	2	168B173   314	2421014031	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			07/20/2016 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	03/21/2022 12:00:00 AM	ADDRESS	34.15889	-118.36851	Plan check for New apartment building 15 units 3 story. Total area: 19871 sq ft. fire alarm variance has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29739	16041-20001-45056	6611-6639 N RESEDA BLVD	91335	3	180B125   833	2126038026	(T)(Q)RAS4-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.19075	-118.53639	Revisions to approved set.  Various changes under delta-1: - switchgear manufacturer changed- main feeder to apartment meter sections modified- - single main service disconnects eliminated in favor of not more than 6 grouped main service disconnects- addition of 2 new subpanels for garage fans- pool panel changed to 3-phase- fire pump meter/disconnect relocated(((Plan check for power and energy. Mixed Use - 5-Story 250-unit  Apartment over 1 story  parking / Retail. (2) 208Y/120V 3ph-4w services at 4000 and 5000A.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29740	16041-20000-41284	4635 N EAGLE ROCK BLVD	90041	14	159A221   348	5473039006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.12854	-118.21768	PLANCHECK FOR T24 ENERGY ONLY. TI AND CHANGE USE OF AUTO REPAIR GARAGE INTO AN DESIGN STUDIO . 2789SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29741	15041-10000-03993	10010 N REMMET AVE	91311	12	204B105   820	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.25239	-118.60035	Title 24 plan check only.  Total area = 8,000 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29742	17041-10002-32602	15920 W ALCIMA AVE	90272	11	129B125   235	4420003007	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.05137	-118.53285	PC FOR LOST SET OF PLANS. THIS IS PLQN CHECK ONLY! PC for five new energy storage units (Powerwall 2's) and 200A load center in SFD. Installing new 200A main  panel. Total of 67.5kWh system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29743	15041-10000-43201	739 S BERENDO ST	90005	10	132B197   333	5094009016	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			12/22/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.05869	-118.29429	PV2, ROOF MOUNTED SOLAR SYSTEM TO UNIT 1 OF 4. (8) MODULES AND (1) CENTRAL INVERTER-3KW-AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29744	12041-10000-30164	11315 S FIGUEROA ST Ste 109	90044	8	087A201   235	6075026029	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	PIN	33.93143118	-118.28297189	application is for plan check and permit. Existing retail space.  Space has been divided in half to create a new space.  Addition of a ADA compliant bathroom and remodel of the light fixtures.  New load is not exceeding 400 amps.  Plan check will be for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29745	12041-20002-12387	215 W 9TH ST 215	90014	14	127-5A209 313	5144017***	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM			Corrections Issued	10/04/2012 12:00:00 AM	PIN	34.04277246	-118.25624184	Supplemental plan check only for Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29746	18041-20000-44843	1206 N CYPRESS AVE	90065	1	147A217   339	5453001016	[Q]C4-1XL-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.09524	-118.22827	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,656 sq. ft.Note: Building permit has been issued under 18016-10000-17165	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29747	19041-10000-32289	621 E 7TH ST	90021	14	126A213   186	5147026002	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM			PC Info Complete	08/19/2019 12:00:00 AM	ADDRESS	34.0403	-118.2459	pc power only new 800A, 120/240V, 3ph,4w for existing warehouse.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29748	11041-10000-07746	635 W WASHINGTON BLVD	90015	9	124-5A205 158	5126002002	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM			PC Approved	04/26/2011 12:00:00 AM	ADDRESS	34.03508	-118.27316	T.1.  EXISTING NISSAN DEALERSHIP.  REPLACING AND RELOCATING LIGHTING FIXTURES.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29749	17041-10000-25600	2264 N HIGHBURY AVE	90032	14	138A237   358	5221014913	PF-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.07101	-118.16235	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING PUMP STATION - SCOPE INCLUDES REPLACING PUMP SYSTEM AND INSTALLATION OF DISTRIBUTION SECTION - PUMPS LOCATED IN HAZARDOUS LOCATION. TOTAL AFFECTED AREA IS 1500 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29750	13041-10000-07906	7747 N DE SOTO AVE	91304	3	189B109   965	2109022012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.21117	-118.58868	INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 5.04 kW. TRANSFORMERLESS INVERTER NON STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29751	12041-10000-14560	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	TI for an existing building. Plan check for power, energy, and emergency lighting. TMZ. Commercial Low rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29752	18041-20000-20150	5219 N CRANER AVE Room 32	91601	2	171B173   519	2416004023	CM-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.1655	-118.36924	Plan check for Title 24 Energy only in existing screen room T.I. new lighting and receptacle. Total area: 475 sq ft. B#17016-10000-18639	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29753	12041-20000-20299	11625 W TUXFORD ST	91352	6	192B169   302	2632020040	[Q]MR1-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	PIN	34.22458891	-118.38547746	New commercial office and manufacturing building.  New 600Amp service.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29754	17041-10000-16186	2060 N VERMONT AVE	90027	4	150B197   260	5590005038	R3-1XL	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	06/05/2020 12:00:00 AM		Issued	06/05/2020 12:00:00 AM	ADDRESS	34.10951	-118.29163	PC FOR POWER AND ENERGY FOR LIGHITNG UPGRADES TO WORSHIP HALL. NEW DIMMER PANEL AND NEW CIRCUITS. PROVIDE T24, AND EMERGENCY PHOTOMETRICS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29755	14041-10006-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			01/28/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	DELTA 16, CHANGES TO THE APPROVED PLANS. SERVICE LOAD CALCULATION BEING UPDTED DUE TO  ONE WHOLE BRANCH OF TRANSFORMERS BEING REMOVED FROM THE PLAN. <<<<<PLANCHECK FOR POWER AND ENERGY FOR  A  NEW 472 Unit Type III  Apt. Building Over Type I Commerciasl Use & Garage Structure. TITLE 24 ENERGY SQFT NOT INCLUDED IN FEES. FEES ARE BASED APPLICANT.>>>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29756	11041-20000-19336	1880 CENTURY PARK EAST 2, 4, 6, 7-Floors	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM	09/12/2011 12:00:00 AM		Permit Finaled	10/21/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	Plan check T24 Energy/Emergency for corridors on floors 2, 4, 6, and 7. Existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29757	17041-10000-18157	16105 W VICTORY BLVD	91406	6	180B141   913	2233025011	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.18686	-118.48412	T-24, REPLACE EXISTING FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 34,600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29758	16041-20000-20001	110 E 9TH ST 12TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR OFFICES (IGNIGHTED SPACES) ON 12TH FLOOR EXISTING HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29759	17041-10000-23703	18529 W CALVERT ST	91335	3	177B125   491	2127015026	(Q) R3-1-K-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.18195	-118.53686	NEW FA SYSTEM FOR 24 UNIT APARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29760	17041-10002-22008	730 S WESTERN AVE #106	90005	10	132B193   477	5093007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.05862	-118.30891	PC for T24 only for relocated lighting fixtures. Permit pulled under master application 17041-10000-22008.Relocating lights and adding new fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29761	15041-20000-20004	8516 W HEDGES PL	90069	4	147B173   546	5559022015	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.09635	-118.37746	Power plan check only.  New SFD with 600 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29762	18041-10000-33064	245 S MAIN ST	90291	11	111B141   545	4286017***	(Q)C4-2D	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	08/17/2020 12:00:00 AM	ADDRESS	33.99681	-118.47872	REPLACE THE EXISTING OBSOLETE FACP WITH A NEW ONE, LIKE TO LIKE.RECONNECT ALL EXISTING DEVICES. NO NEW DEVICES ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29763	19041-20002-17198	3536 N LOWRY ROAD	90027	4	153A203    29	5592008001	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.1156	-118.27781	08-23-2019 Changes to an approved set of plan delta 1 only, Changes include providing fusible disconnect and EATON load center. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29764	12041-10000-05171	1711 W 253RD ST	90717	15	036B193   310	7410015058	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	33.7949	-118.30815	INSTALLATION OF 3.60KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A CONDOMINIUM BUILDING (STAND-ALONE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29765	18041-20000-30773	16660 W LABRADOR ST	91343	12	201B137   302	2686004010	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	PIN	34.2490813	-118.49588086	Plan check for a PV1 roof-mounted PV system. System size is 4.29 kWdc/4 kWac-CECand consists of (1) inverter and (13) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29766	12041-10000-22415	8500 W BEVERLY BLVD 605	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI  OF AN (E) 801 SF RETAIL SPACEplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29767	14041-20001-24308	13854 W MAGNOLIA BLVD	91423	4	171B153   466	2269006002	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.16466	-118.43527	Expedited plan check per applicant request.  PV1.  Install 14.0 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29768	11041-20000-07558	5477 N NESTLE AVE	91356	3	174B125   498	2160018***	R3-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	12/27/2011 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.1703	-118.5299	Upgrade to 1200 Amp service due to fire damage equipment.  Install new main panels.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29769	16041-10000-18374	12030 W RYNGLER ROAD	91604	2	162B165   675	2369019031	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.13985	-118.39295	Note: Permit is $0 due to senate bill 1222New 12 kW AC PV installation. 44 Canadian Solar PV modules. Installing 2 SMA SB6000TL-US Inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29770	19041-10001-28145	10601 N COZYCROFT AVE	91311	12	207B109   488	2707010009	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.26281	-118.58229	PV1. New solar system on existing residential roof-top. Total system size is 11.34KWdc/10.16KWac with (1) load center,  (36) modules and micro inverters inter connecting through the main service panel.Note:  Portion of Permit fees are paid under master application 19041-90000-28145	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29771	19041-20000-02515	400 S HOPE ST 3RD FL	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.05199	-118.25366	PLAN CHECK FOR TITLE 24 ONLY TENANT IMPROVEMENT TO AN EXISTING OFFICE BUILDING FLOOR. SCOPE OF WORK INCLUDES 22940 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29772	13041-20000-15979	13429 W VANOWEN ST	91405	2	183B157   950	2328031012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			06/17/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.19412	-118.42557	New Fire alarm system for a new building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29773	12041-10000-14094	20948 W TULSA ST	91311	12	210B109   367	2706005004	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.26797	-118.59022	INSTALLATION OF A  15.696KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD.SYSTEM CONSISTES OF INVERTERS, 48 SOLAR MODULES, WIRING AND PANELBOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29774	16041-30000-01088	19737 W BRYANT ST	91306	3	195B117   313	2782021011	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.22739	-118.56376	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (24) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29775	17041-20000-33838	10773 W ASHTON AVE	90024	5	132B153   319	4325004013	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			09/21/2017 12:00:00 AM			Reviewed by Supervisor	11/01/2017 12:00:00 AM	ADDRESS	34.0592	-118.43836	Plan check for power and energy. New 5-unit, 4-story apartment building over one level of underground parking. 800A 120/240V 3ph 4w service. Total T24 area - 8,878sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29776	16041-10002-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	"PC FOR CHANGES TO APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA ""DCN-017"". CHANGES INCLUDE RELOCATING MOTOR CONTROL PANELS FROM PANELS PDP-A&B TO DISTRIBUTION BOARD ""DSB-A"",  ADDING ONE NEW MCP TO DISTRIBUTION BOARD ""DSB-A"", AND ADDING OUTDOOR LIGHTS/TITLE 24."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29777	10041-10000-06234	300 S DOHENY DR 2nd Floor	90048	5	138B169   549	4335015050	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	07/01/2010 12:00:00 AM	ADDRESS	34.07343	-118.38954	Plan check for T-24 Energy outdoor fitness area on 2nd floor (Pool Deck).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29778	15041-20000-15018	14000 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.15735	-118.43783	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the installation of lighting and power. Total lighting area = 5,074 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29779	11041-20000-18920	9301 N TAMPA AVE 29A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM			PC Approved	09/07/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	T-24 onlyexist. permit 11041-20000-13865	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29780	14041-10000-12720	1626 N BENTON WAY	90026	13	144A207   287	5423014022	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.0871	-118.26609	Install roof mounted solar arraySystem size = 4 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29781	11041-20000-10206	16133 W VENTURA BLVD # PH.A	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM	05/18/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.15675	-118.4847	Plan check T24 Energy general/emergency lighting for TI: Extend Suite # PH.A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29782	14041-10000-03663	28200 S WESTERN AVE	90732	15	024B193   622	7442030207	P-1XL, [Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	33.76345	-118.31125	Plan check per inspector request. Carrow's restaurant. PC for energy only. Changes on plan: emergency lights (bugeyes) to be on same circuit as general lighting.TI--REBUILD (E) RESTROOMS FOR ACCESSIBILTY, RESTRIPE A PORTION OF THE  PARKING LOT , AND CREATE ACCESSIBLE PATH OF TRAVEL. NO CHANGE IN PARKING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29783	17041-10000-45092	300 W AVENUE 33	90031	1	142-5A221 290	5205006053	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.08346	-118.21585	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29784	17041-20001-05743	60 N BEVERLY PARK	90210	4	156B161    81	4386013013	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.12101	-118.4164	10/13/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the series-rating breaker combinations. *****Previous Work Description*****Plan check for power only. Project site is an existing SFD. Project scope is a service upgrade and refeeding certain distribution equipment.Note: Building permit has been issued under 15016-20000-10640	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29785	15041-20001-24129	6256 N TOPANGA CANYON BLVD Ste C1210	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	0-11-2015 Change to approved set of plans. Changes include remove disconnect from secondary of the transformer side. Changes apply to delta 3 only.{{{{{TI to retail space (clothing store). First time tenant. Plan check for power and energy. Total sqft. 1,380.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29786	14041-20001-02280	6153 N FENWOOD AVE	91367	3	177B093   379	2035014003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.18242	-118.63354	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING SOLAREDGE TOTAL SYSTEM SIZE 6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29787	18041-10000-42800	6075 W HARGIS ST Lot A	90034	10	123B173   898	5065005019	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Issued	11/07/2018 12:00:00 AM	ADDRESS	34.0326	-118.37653	"NEW ROOFMOUNTED 2.2KW PV SYSTEM WITH 7 MODULES ON SINGLE FAMILY HOUSE. Lot ""A""BLD#16010-10000-05438"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29788	19041-20002-06872	8700 S PERSHING DR PV4	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Revisions to approved set of plans and change of scope of work.  Approval for clouded changes delta-1 only.  Work description change: PV2.  Install 24.82 kW DC / 22.68 kW AC roof mounted grid tied PV system.  (68) modules with (1) 20 kW rated inverters.  Interconnecting with MSA-4.  (((PV2.  Install 25.55 kW DC / 23.34 kW AC roof mounted grid tied PV system.  (70) modules with (1) 20 kW rated string inverter.  Interconnecting with MSA-4.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29789	15041-10000-40925	331 1/2 E 1ST ST	90012	14	130-5A215 321	5161012012	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.04992	-118.23998	NEW FIRE ALARM SYSTEM TO A COMMERCIAL BUILDING, HOTEL. 102 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL AND 1 REMOTE POWER SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29790	10041-10000-25422	10968 W WILKINS AVE	90024	5	132B153   980	4324038004	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			12/22/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.05403	-118.44371	New fire alarm for 5 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29791	11041-10000-17946	1050 N ALAMEDA ST	90744	15	033B213   369	7425041001	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	33.78517	-118.24296	NEW OUTDOOR LIGHTING FOR AN EXISTING MOTEL.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29792	14041-20000-31639	7743 N GENESTA AVE	91406	6	189B133   822	2203009009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Expired	12/07/2016 12:00:00 AM	ADDRESS	34.21161	-118.50346	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.5 KW.( 36) KYOCERA # KD255GX (1) FRONIUS IG PLUS 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29793	16041-20000-21937	7933 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.21486	-118.53492	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29794	11041-20000-25282	9338 N DEBRA AVE	91343	12	198B137   360	2676006020	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2011 12:00:00 AM	04/02/2012 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	ADDRESS	34.2404	-118.49033	6.27 KW PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29795	11041-10001-03163	303 S GAFFEY ST	90731	15	018B197  1550	7451020033	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro	YES	2966.00	Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	33.74122	-118.29251	INTERIOR UPGRAGE TO DINING AREA.PLAN CHK IS FOR TITLE 24.change of lights from flourecent to LED(S).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29796	13041-20000-10395	2001 W JOHN S GIBSON BLVD	90731	15	024B201    45	7440016911	[Q]M3-1VL	Harbor	Port of Los Angeles	Northwest San Pedro	YES	9800.31	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			PC Approved	05/08/2013 12:00:00 AM	ADDRESS	33.75887	-118.28777	Plan check for energy and emergency lighting. Low-rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29797	15041-10000-19680	6221 W 96TH ST	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	33.94902	-118.39331	T24. PERMIT ISSUED FOR REPLACEMENT OF LIGHITNG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29798	13041-10000-01903	712 W 1ST ST	90012	14	132A211    38	5151002***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM			Ready to Issue	01/24/2013 12:00:00 AM	ADDRESS	34.05659	-118.25057	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING IN  A BEAUTY SALON (1,150 SQ FT).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29799	10041-10000-12404	6675 W HOLLYWOOD BLVD	90028	13	148-5A185  90	5547009006	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Public Safety Only			06/29/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.10173	-118.33567	fire warning system with central station monitoring for full evac system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29800	13041-10000-14403	8631 W 3RD ST 4TH FLOOR	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			Verifications in Progress	07/10/2013 12:00:00 AM	ADDRESS	34.07373	-118.38036	TENANT IMPROVEMENT. EXISTING OFFICE INA MEDICAL BUILDING. OFFICE HAS NO MEDICAL USE OR MEDICAL EQUIPMENT. TENANT WILL BE NON MEDICAL. PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING. PROJECT LOCATED IN A HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29801	19041-10000-44478	600 W PACIFIC COAST HWY	90744	15	036B205  1178	7420001028	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	33.79063	-118.26984	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFITS KITS OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29802	19041-20000-02668	1355 S HOPE ST	90015	14	126A207   228	5134011023	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			01/23/2019 12:00:00 AM			PC Info Complete	03/29/2019 12:00:00 AM	ADDRESS	34.0382	-118.26675	Plan check for power only. Project site is an existing 4-story, 55-unit apartment building. Project scope is a service upgrade to 800 amps, new distribution equipment, and new circuits for unit loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29803	15041-10001-14231	600 WORLD WAY Terminal 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	8/25/15: Supplemental, changes on light fixtures(T-24 FOR TWO KITCHEN SPACES IN LAX, TOTAL SQ. FT. 1190)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29804	16041-10001-01167	188 S JUNE ST	90004	4	138B185   422	5515002009	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.07145	-118.33464	EXPEDITE PER APPLICANT REQUEST.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 22.05kWdc / 22.4kWac.(70)MODULES-LG ELECTRONIC LG315N1C-G4(2)INVERTERS-SMA AMERICA SB-7700TL-US-22 AND (1)INVERTER-SMA AMERICA SB-7000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29805	18041-30000-43450	1265 S STEARNS DR	90035	5	129B173   236	5087016013	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Apartment			11/13/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	02/07/2022 12:00:00 AM	ADDRESS	34.05271	-118.37112	PROPOSED MIXED USE APARTMENT WITH RETAIL AND PARKING GARAGE. 1600A 120/208V service. 6-story, (48) units with (11) typical units.  Total area: 35,669 sq.ft((B# 15010-10000-04512))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29806	13041-20001-21003	2466 E 16TH ST	90021	14	118-5A217 283	5168010007	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.01949	-118.2277	New 2000 amp commercial building.  Plan check for Energy is on the Main application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29807	15041-20000-22285	14807 W ARARAT ST	91342	7	228B149   216	2502015054	R1-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Expired	08/08/2017 12:00:00 AM	ADDRESS	34.32145	-118.4558	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (26) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29808	14041-10002-34971	416 S WESTLAKE AVE	90057	1	133-5A205 196	5154026015	R4-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			05/03/2016 12:00:00 AM			PC Info Complete	05/19/2016 12:00:00 AM	ADDRESS	34.06015	-118.27263	THIS IS PLAN CHECK FOR 600A SERVICE. ORIGINAL PERMIT ALREADY PAID FOR. CONTRACTOR MUST BE CHANGED TO C10 LICENSE FOR THIS SERVICE UPGRADE. INSTALLING NEW 600A 1PHASE SERVICE FOR APARTMENT. ALL UNIT PANELS ARE TO REMAIN. REPLACING HOUSE PANEL AND RECONNECT EXISTING CIRCUITS. NO NEW LOADS AND NO NEW CIRCUITS. THIS IS PLAN CHECK ONLY. PLAN CHECKER TO VERIFY NEW FAULT CURRENT RATINGS AND INTEGREDY OF EXISTING PANEL BOARDS. NEW SUBMITTAL PER MZ	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29809	18041-20000-33843	20613 W CHESTNUT CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.29279	-118.58367	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29810	11041-10000-03592	163 N GROVERTON PL	90077	5	138B149   116	4362008007	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2011 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.07515	-118.44924	NEW PV PANEL FOR EXISTING RESIDENTIAL.  74X185W ROOF MOUNTED PV ARRAY WITH 2 INVERTERS, 2 COMBINERS, AND SUB-PANEL.  EXISTING 400 AMP SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29811	19041-20000-20476	10140 N HILLHAVEN AVE 1-34	91042	7	204B197   997	2565013041	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1012.10	Electrical	Electrical	Apartment			05/30/2019 12:00:00 AM	04/24/2020 12:00:00 AM		Permit Finaled	10/26/2022 12:00:00 AM	ADDRESS	34.2535	-118.28968	1200A 208Y/120V 3ph-4w service.  Plan check for power and energy.  Building permit under 18010-20000-06009.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29812	19041-20000-22568	15136 W GILMORE ST	91411	6	180B145   725	2235020004	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.18737	-118.46308	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6.71KW DC/7KW AC. SCOPE OF WORK INCLUDES (22) S-ENERGY PV MODULES AND A SMA7.0-US INVERETER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29813	19041-10000-09173	2950 S OVERLAND AVE	90064	5	123B161   488	4255009901	OS-1XL	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	03/25/2021 12:00:00 AM	ADDRESS	34.03295	-118.41773	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29814	19041-10000-34453	4345 S CRENSHAW BLVD	90008	8	111B185    46	5024006012	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Issued	09/03/2019 12:00:00 AM	ADDRESS	34.00419	-118.33292	RE-ENERGIZE VANDALIZED EXISTING 800A 120/240, 3PH 4W SERVICE. ALL LOADS ON PANELS A, B, C AND D ARE FUTURE LOADS TO BE PERMITTED SEPERATELY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29815	15041-20000-40163	701 E 3RD ST	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	PIN	34.04581508	-118.23784015	Fire alarm plan check only. Install a new fire alarm system in a four story commercial building. 203 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29816	17041-10000-05827	3264 E MINES AVE	90023	14	118-5A223 112	5190029033	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.01857	-118.20823	PC for indoor/ outdoor  title 24. Removing HID fixtures and replacing them with new LED ones. Area: 12,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29817	15041-10001-12501	7920 W SUNSET BLVD	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	34.09787	-118.36238	Plan check for power only. Adding non-life-safety circuit to emergency generator. New ATS, transformer, and panel. Check new distribution equipment and load on generator. Branch circuits on panels not checked under this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29818	14041-10000-14384	1035 S TOWNE AVE	90021	14	124-5A211 317	5132010039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.03351	-118.25036	PLAN CEHCK FOR ENERGY ONLY FOR EXISTING RETAIL STORE. LIGHT RETROFIT ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29819	17041-20001-18649	12500 N MIDDLECOFF PL	91344	12	219B137    31	2605004020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			Verifications in Progress	07/05/2017 12:00:00 AM	ADDRESS	34.29917	-118.49517	expeditepv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29820	10041-10000-14682	22649 W VENTURA BLVD	91367	3	171B097   166	2040028010	C1.5-1VLD, C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	08/02/2010 12:00:00 AM		Permit Finaled	09/28/2010 12:00:00 AM	PIN	34.16770476	-118.62042219	T.I. to existing building.  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29821	10041-20000-10952	970 W 190TH ST #900 & 920	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM			PC Info Complete	06/09/2010 12:00:00 AM	ADDRESS	33.85812	-118.29302	Plan check T-24 energy (general/emergency) lighting for office area in suite #900 & #920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29822	15041-10000-04630	8559 W EDWIN DR	90046	4	156B169   341	5565044010	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.12115	-118.38741	pv1. plan check only.  FEES FOR LOST PLANS RECHECK . refer to 14041-10002-32975 for the last revision.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29823	18041-20001-26119	145 S DOHENY DR	90048	5	138B169   497	4335007036	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.07395	-118.39001	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 43.89 kWdc/37.86 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (114) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29824	10041-30000-02931	1870 S VETERAN AVE	90025	5	129B153   821	4323007***	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM			PC Approved	02/18/2010 12:00:00 AM	ADDRESS	34.04744	-118.43865	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY LIGHTING) FOR LOBBY AREA.  24 HOUR OPERATION NO AUTO SHUT-OFF.  PERMIT IS FOR INSTALLING NEW LIGHT FIXTURES ON EXISTING BRANCH CKT.  MR-16 FIXTURES SHALL NOT EXCEED 50W.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29825	14041-10000-20392	20700 W SESNON BLVD	91326	12	219B109     5	2701001040	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			Verifications in Progress	12/16/2014 12:00:00 AM	ADDRESS	34.29545	-118.58467	PLAN CHECK FOR T24 ENERGY. OUTDOOR SITE LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29826	18041-20000-38383	19615 W ROSCOE BLVD	91324	12	192B117   699	2783012012	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	PIN	34.22105589	-118.56075713	Plan check for a PV1 roof-mounted PV system. System size is 16.2 kWdc/14.66 kWac-CEC and consists of (45) micro-inverters, (45) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29827	19041-30000-22563	8425 N LAUREL CANYON BLVD	91352	6	192B165   289	2633006018	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1210.10	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.22407	-118.39842	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to a pharmacy area. Total lighting area = 1,185 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29828	19041-20001-32252	401 S LORING AVE	90024	5	138B153   168	4359005001	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.07517	-118.4348	Plan check approval for system permitted under 19041-90000-32252 per applicant request.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29829	19041-10000-37573	817 N LELAND ST	90732	15	021B193   238	7446014016	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	33.75054	-118.30117	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 18 MODULES (CANADIAN SOLAR 320), OPTIMIZERS (SE P400) AND 1 CENTRAL INVERTER (SE5000H-US). SYSTEM SIZE IS 5.76KWdc AND 5KWacSTANDARD PLANS SUBMITEED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29830	14041-10001-19201	1062 S STEARNS DR	90035	5	132B173   727	5087019025	R1-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	34.05692	-118.36878	"""Fee is  $0 due to the 2012 Senate Bill No. 1222"" Change of work description to reflect number of modules installed: PV1 10KWAC. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {SMA 10000TL-US}]. [(39)modules: {solarworld SunModule SW-270 mono }]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29831	14041-10000-05675	3414 W 76TH ST	90043	8	099B185    92	4012021023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	33.97072	-118.33158	PV1, INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(13) MODULES: TRINA SOLAR TSM-250PA05.18(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29832	19041-10000-11446	333 S HOPE ST 55TH FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	04/07/2020 12:00:00 AM	ADDRESS	34.05326	-118.25292	FULL PLAN CHECK FOR - INTERIOR TI OF AN EXISTING OFFICE TI INCLUDE NEW PARTITIONS, CEILINGS, LIGHT FIXTURES, FINISHES, ADD RAISED FLOOR AND BEAMS  AREA 16,538 USF - TOTAL NEW CONNECTED LOAD IS APPRX 400A TO EXISTING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29833	17041-10000-34988	421 S CHICAGO ST	90033	14	126A221    21	5183018035	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.04113	-118.21479	PC for T24 only for removal of HID fixtures and replace with new LED fixtures. Total of 11950sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29834	16041-20000-43077	21800 W OXNARD ST Suite 770	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for energy only. Relocate 2 lights in office suite 770 room, add new receptacle. 849sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29835	16041-10000-44809	450 S WESTERN AVE #222	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			Corrections Issued	12/21/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	Plan check for power and energy for 1st time tenant in retail and coffee shop space. Total area: 4180 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29836	18041-10001-09369	9030 N OWENSMOUTH AVE	91304	3	195B105    34	2779018012	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM			PC Approved	10/16/2018 12:00:00 AM	ADDRESS	34.23452	-118.60151	10/16/2018Changes to an approved set of plans not changes under delta 2 and delta 3 only. plan check only. ______________________Change of use from warehouse to commercial kitchens.  Building permit under 18016-20000-07799.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29837	16041-20000-27489	800 S FIGUEROA ST #1200	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 12TH FLOOR.  3,795 SF SUITE #1200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29838	17041-10000-24756	915 W WILSHIRE BLVD 2125	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.05069	-118.2599	Energy plan check for an office T.I, Total area is 2100 SQ FT. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29839	16041-20003-06615	2888 W ROWENA AVE	90039	4	151-5A205 221	5434035027	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM			PC Approved	05/31/2016 12:00:00 AM	ADDRESS	34.10798	-118.26744	Revisions to approved plans.  Approval for Sheet E2.1 only - sheet missing from original RTI package.  Plan check only for 1st floor lighting plan.  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is power and lighting to a new additional building and a service upgrade. Total lighting area = 3,944 sq. ft.Note: Building permit has been issued under 15010-10000-02284)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29840	18041-10001-03110	400 S BROADWAY	90013	14	129A211   293	5149024***	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Closed	07/21/2020 12:00:00 AM	ADDRESS	34.04925	-118.24934	Changes to an approved set of plans. All changes are clouded under delta 4. Changes include adding new panel boards, new circuits, revising single line diagram, and revising power/lighting floor plans. Original plan checker is Francis Ysaguirre.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29841	17041-10000-18479	19735 W DEARBORN ST	91311	12	198B117   165	2761001056	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.23741	-118.56336	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29842	19041-10000-32960	9501 N EL DORADO AVE	91352	6	198B165    14	2629006008	MR2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.24121	-118.39925	Remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor) -T24 only. Replace fluorescent troffers with new LED retrofit kits.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29843	14041-10001-35352	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	06/28/2016CHANGES TO AN APPROVED SET OF PLANS.  22 BOOSTER PANELS WERE RELOCATED ONE FLOOR ABOVE AND 6 DEVICES WERE ADDED.  PC FOR ALL CHANGES.  PERMIT FOR NEW DEVICES ONLY UNDER INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29844	15041-20000-12022	3900 N STANSBURY AVE	91423	4	162B153  1094	2274027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.14084	-118.44264	TI to existing building being remodeled (school). Plan check for energy only. Adding new lighting including emergency.  Total sqft. 2,540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29845	15041-10000-01503	13843 W OSBORNE ST	91331	6	198B153   900	2642029007	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.23567	-118.43526	Plan check for PV1 roof mounted, system size: 3.6 kWac with 16 modules. Using standard plan.Reason for Submit over the counter: Unable to submit online due to load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29846	18041-20000-04874	1111 S HOPE ST	90015	14	127-5A207 240	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Issued	02/09/2018 12:00:00 AM	ADDRESS	34.0422	-118.26337	replace existing metal halide fixture with new led fixtures.  plan chweck for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29847	17041-20000-34669	13360 W JAVA DR	90210	5	159B157   271	4385004005	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.12906	-118.4244	Plan check for the addition of a battery back-up system to an existing PV system for a single-family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29848	14041-20000-14857	20203 W SATICOY ST	91306	3	186B113   168	2114004043	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.20847	-118.57321	T.I. to existing Veterinary building.  Install new lighting in dog cage, lounge, x-ray, and groomming areas. Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29849	14041-20000-10769	11256 N GLENOAKS BLVD	91331	7	210B161   139	2533019032	[Q]C2-1VL-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	PIN	34.27454105	-118.41169131	Change of use from restuarant to dental clinic.  Install new panel, branch circuits, and lighting.  Plan check for power and energy.Note: PARTIAL of permit issued under X14VN06253 (14041-20000-09131)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29850	14041-20000-05135	15005 W VENTURA BLVD	91403	4	168B145  1025	2264016001	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.15295	-118.45985	T24 FOR EXISTING RETAURANT. OCCUPANT LOAD DOES NOT EXCEED 99 OCCUPANTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29851	13041-20000-08656	3620 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.0213	-118.28935	Change to lighting/loads to an existing Laboratory Classroom, with an occupancy load of 49.  New panels and load is 413 amps.  Full Plan Check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29852	17041-10001-07959	3785 W WILSHIRE BLVD 104D/E	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			PC Approved	03/17/2017 12:00:00 AM	ADDRESS	34.06187	-118.30858	Changes to approved set. Changes include additional track lights and rearangement of  luminres.plan check only permit ot be pulled under master. T-24, PC FOR ENERGY ONLY.CHANGE OF USE FROM RETAIL TO OFFICE (1670 SF) ON GROUND FLOOR OF EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1515 SQ. FT.  b#17016-10000-02836	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29853	19041-20001-24481	15553 N SORBONNE ST	91342	7	228B141   208	2603020009	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.32148	-118.47498	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGE TO APPROVED SET, CHANGE TO SINGLE LINE DIAGRAM AND LOAD CALC. CHANGE TO THE MAIN DISTRIBUTION CHANNEL. CLOUDED DELTA A CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29854	18041-10000-41058	2802 N FIGUEROA ST	90065	1	142-5A221 183	5446017036	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Issued	10/26/2018 12:00:00 AM	ADDRESS	34.08479	-118.2209	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29855	13041-10000-24701	6132 S HARCOURT AVE	90043	8	105B181   918	4004027016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	33.98362	-118.34056	PV1 4.42KWdc.240V.xmfrLESS/Ungnd.NONstd.1story.Roofmount.[(1) inverters:{PVI-3.6-OUTD-US }]. [(17)modules:{BenQ PM250M01_260W}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29856	14041-20000-31351	6011 N WOODLAKE AVE	91367	3	177B093   669	2035024057	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.17949	-118.63228	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.0KW INTERCONNECTED WITH MSP.(20) LG305N1C-B3 MODULES(20) ENPHASE M250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29857	19041-20000-15782	5205 N HARMONY AVE	91601	2	171B173   562	2416009027	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			04/29/2019 12:00:00 AM			PC Info Complete	08/26/2021 12:00:00 AM	PIN	34.16516585	-118.36657837	Install new 1600 amp 120/208v 3p 4w service. Install new panels, equipments and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29858	12041-10001-07249	14018 W ADDISON ST	91423	4	171B153   804	2269013031	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2012 12:00:00 AM			PC Approved	05/04/2012 12:00:00 AM	ADDRESS	34.16116	-118.43843	PLAN CHECK FOR ROOF MOUNTED 6.84KW PHOTOVOLTAIC SYSTEM. EXISTING PERMIT ON #12041-20000-07249	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29859	14041-10001-21463	3335 S FIGUEROA ST O	90007	9	120A203   503	5123009042	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	34.02224	-118.28008	Modifications to approved set.   Relocation of rooftop equipment and changes to lighting system resulting from increased walk-in cooler size on architecturals.  (((Plan check at counter. New power/lighting system upgrade. electrical service for sub-lease space. T24. Area = 3450 sq. ft. 8 story building High rise)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29860	10041-20000-03333	1875 S CENTURY PARK EAST 23rd fl.	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles - Century City - Rancho Park			2671.00	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	04/21/2010 12:00:00 AM		Permit Finaled	07/13/2010 12:00:00 AM	ADDRESS	34.06115	-118.41457	Tenant improvement - remodel for 23rd floor in high-rise building. Title 24 and emergency egress only. variance to separate FA submitted	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29861	18041-20000-15996	8338 W 3RD ST	90048	5	138B173   876	5511031030	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.07268	-118.37138	TI to (E) commercial restaurant space.  New 800A 240/120V 3ph-4w service.  Building permit under 17016-10000-38540.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29862	16041-10000-44466	10628 S MANHATTAN PL	90047	8	090A193   232	6058024015	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	33.93922	-118.31004	PC FOR ROOFTOP MOUNTED SOLAR. PV SYSTEM USING 3KW AC CENTRAL INVERTER WITH 12 MODULES IN TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29863	13041-10000-17604	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	33.97451	-118.42531	plan check requested by applicant. PC FOR POWER-. 2 NEW PANELS (L3PA & H3P). (1) 30KVA XFMR. 3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29864	19041-20000-36009	3434 S GRAND AVE 2ND FL MEZ	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/17/2020 12:00:00 AM	ADDRESS	34.01912	-118.27658	TENANT IMPROVEMENT OF LAB P.C FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29865	15041-20000-23709	1110 S WESTERN AVE #203	90006	10	129B193   694	5080010002	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.05041	-118.30886	Title-24 plan check only.  Total area = 1,450 sq. ft.  T.I. to existing office and storage space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29866	10041-10000-10905	200 N VERMONT AVE	90004	13	138B197   493	5501010032	C2-1	Central	Wilshire	Rampart Village	YES	2111.10	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	09/02/2010 12:00:00 AM	ADDRESS	34.07496	-118.29147	Ti in an existing commercial building. Plan check for Energy and T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29867	10041-10000-18847	1297 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/27/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.05172	-118.22501	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29868	19041-20001-52095	7539 W SUNNYWOOD LANE	90046	4	156B177   176	5570034013	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM			PC Approved	03/12/2020 12:00:00 AM	ADDRESS	34.12618	-118.36184	PV1 PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 10.8 KW DC/9.778 KW AC CEC. ESS SIZE IS 20 KWH. SCOPE OF WORK CONSISTS OF (30) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, A LOAD CENTER,  AND A 8 KVA BATTERY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29869	14041-10002-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM			PC Approved	03/02/2015 12:00:00 AM	ADDRESS	34.0504	-118.26023	"DELTA REVISIONS TO PERMITTED SET OF PLANS. ATTACHED TO THE SUBMITTAL ARE THE LISTS OF CHANGES WITH CORRESPONDTNG SHEET PLANCHECK FOR POWER AND ENERGY. HIGH RISE CORE AND SHELL BUILDING INCLUDING 5 LEVEL PARKING GARAGE. "" WILSHIRE GRAND "" PROJECT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29870	13041-20000-34593	3624 N GLENRIDGE DR	91423	4	162B157   979	2272028010	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.13617	-118.43264	New rooftop PV system for an existing sfd.  System is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29871	17041-20000-38792	1800 CENTURY PARK EAST 2nd Floor-Restroom	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	PIN	34.06270629	-118.4150769	Plan check for energy only. TI to bathroom on second floor of high rise building. New lighting (incl. emergency) - 308sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29872	16041-20001-10190	21407 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.2574	-118.59765	05/16/2016 Plan check for Title 24 for a lost set of plans. Scope of work has remained the same.*****Previous Work Description*****Plan check for energy only. Change use of tenant space from retail to restaurant. Add new lighting in new bathrooms. Add emergency buglights in dining area. 1,004sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29873	17041-20001-34074	16642 W SUPERIOR ST	91343	12	201B137   598	2686007013	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM			PC Approved	10/09/2017 12:00:00 AM	ADDRESS	34.24687	-118.49515	9.28.2017 - Plan check for AC coupled battery backup system. (1) 8kW Sonnen battery system. Existing solar system on site.Permit pulled under master application #17041-90000-34074.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29874	17041-10000-24283	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC for power and energy per applicants request. TI for new beverage and bar area in LAX terminal 3. Total area is 900sqft. Building PC 17016-10000-19676.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29875	12041-20001-02694	7518 N DEERING AVE	91303	3	186B105   305	2112007013	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Info Complete	06/17/2013 12:00:00 AM	ADDRESS	34.20699	-118.59654	Modification to previously approved drawings.  Change to Panels, UPS System, lighting.  Full Plan Check.       Install new 800 amp service, optional standby generator, switchboad, subpanels, branch circuits, and lighting for unmanned cable headend facility.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29876	19041-20001-33076	3918 N SCADLOCK LANE	91403	4	163-5A145 102	2281015011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.14194	-118.46874	CHANGES TO APPROVED SET DELTA 1 ONLY. RELOCATION OF STORAGE BATTERY AND REMOVE AC DISCONNECT.<<<INSTALL 2 NEW TESLA ENERGY STORAGE BATTERIES.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29877	12041-10000-29589	5612 W 79TH ST	90045	11	099B173   489	4105028013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	33.96627	-118.37921	New roof mounted 3.43 kw PV1 for a single family. (X-formerless INV with optimizer)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29878	18041-20001-48292	637 W 77TH ST	90044	8	099B201   199	6020019015	[Q]R3-1	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	33.96989	-118.28532	CHANGES TO APPROVED SET OF PLANS -CHANGES INCLUDE LOCATION OF NEW AND EXISTING EQUIPMENT LOCATION - ALL PV SYSTEM STAYS THE SAME ORIGINAL PERMITPC FOR NEW ROOFTOP 7.6KW AC PV SYSTEM, (18) DC MODULES, (18) P320 OPTIMIZERS, 1 7.6 KW AC SE7600A-USS2 INVERTER, (1) 5 KW ENERGY STORAGE SYSTEM, (1) NEW 5KW AUTOTRANSFORMER, (1) NEW 200A PANEL, AND (1) NEW 100A PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29879	15041-10000-04468	5443 W FOUNTAIN AVE	90027	13	147A193   238	5544031002	C2-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	PIN	34.0952534	-118.30846255	Title 24 plan check only.  Total area = 5,483 sq. ft.T.I. to existing (non-highrise) office space including new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29880	17041-20000-16274	8088 N MCDERMOTT AVE	91335	12	189B129    58	2101012016	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.21821	-118.52391	pv1install roof mounted pv system sized 6.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29881	11041-20000-21346	700 S FLOWER ST Ste 1215	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.04835	-118.25882	T.I.  Office remodel of suite # 1215.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29882	12041-10000-30851	2136 W COLORADO BLVD	90041	14	162A223   131	5686003011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM			PC Approved	12/24/2012 12:00:00 AM	ADDRESS	34.13893	-118.21327	retail space being converted to restaurant space. application for t24. T.I. also for emergency lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29883	11041-10000-15349	21925 W DEVONSHIRE ST	91311	12	204B101   147	2722018025	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/21/2011 12:00:00 AM	ADDRESS	34.25741	-118.60575	TI TO AN EXISTING 7-ELEVEN.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29884	11041-10000-20322	18461 W ROSCOE BLVD	91325	12	192B125   655	2786022017	C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.2209	-118.53566	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29885	15041-10000-30135	1691 E 111TH ST	90059	15	088-5A213 410	6069011031	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	33.93493	-118.24289	PV1, INSTALL NEW 3.445 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(13) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29886	18041-30000-00459	13209 W MOORPARK ST	91423	4	165B157   317	2360030039	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.15049	-118.42075	Plan check for 6 units appartment 600 A Service 3 story. Total area: 5,649 sq ft. B#17010-20000-03441	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29887	18041-10001-43372	25420 S MCCOY AVE	90710	15	036B197  1146	7413024162	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2019 12:00:00 AM			PC Info Complete	03/21/2019 12:00:00 AM	ADDRESS	33.79301	-118.28975	NEW ROOF MOUNTED 2.24KW PV SYSTEM WITH 8 PV PANELS ON A SINGLE FAMILY HOME.BUILDING PERMIT: 15010-10000-04018 & 15010-20001-04018	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29888	18041-20000-18455	14836 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.29484	-118.45432	Plan check for a PV1 roof-mounted PV system. Plan check size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29889	12041-20000-11592	8922 N RESEDA BLVD	91324	12	195B125   339	2769002005	C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	05/25/2012 12:00:00 AM	ADDRESS	34.23265	-118.53588	Tebobo rest.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29890	13041-20000-03945	1491 S OAKHURST DR	90035	5	129B169   275	4306005006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Expired	11/12/2015 12:00:00 AM	ADDRESS	34.05264	-118.39112	New 9.16kw DC PV system.  Rooftop mounted, sfr.  System uses battery backup.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29891	19041-20001-01504	12830 W RAYMER ST	91605	2	186B161   542	2324005024	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.20426	-118.4128	Revisions to approved plans.  Plans modified to remove controlled receptacles from alteration work.(((Plan check for Title 24 only in existing space remodel interior Tenant Improvement. Total area: 5884 sq ft. B#18016-20000-39604)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29892	17041-10000-42899	2112 W SUNSET BLVD UNIT H	90026	13	139-5A207 108	5402035003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.07733	-118.26419	PC FOR T-24, ENERGY ONLY FOR CHANGE OF USE FROM RESTAURANT TO RETAIL . SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1296 SQ. FTb# 17016-10000-34220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29893	16041-10000-05067	14031 W VICTORY BLVD Apt 2	91401	2	180B153  1077	2238025005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.18683	-118.43882	Installation of new roof mounted PV array on existing apartment building for Apt. 2.  System consists of a 3 kWAC inverter and 9 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29894	15041-10000-23076	3650 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.02081	-118.28964	ALTERATIONS FOR LIGHTING AND POWER IN EXISTING CLASS ROOMS100B and 100CIN THE USC OLIN HALL OF ENGINEERINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29895	14041-10000-11266	10865 N PLAINVIEW AVE	91042	7	207B197   226	2557007014	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.26667	-118.29815	PV 1 - Install roof-mounted solar array, interconnect with main panel.System size = 9.75 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29896	17041-20000-36046	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.24912	-118.34256	Plan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.5.2kW unground pv system. (21) 315W pv modules. (1) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29897	15041-20002-02760	6530 N SEPULVEDA BLVD	91411	6	180B145   491	2235002005	R1-1, R4-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.18936	-118.46595	"[[[3/22/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA ""D"" CHANGES ONLY. CHANGING EMERGENCY LIGHTING FROM INVERTER CIRCTUITS TO BATTERY BACKUP IN CORRIDORS AND OUTDOOR LIGHTING.]]]]6.14.2017 - Plan check for modifications to approved set. Split MSA into MSA1 and MSA2. Update a couple of unit floor plans. Rearrange a couple of units. Expand Gym. Changes clouded delta C.=====NEW 68 UNIT APARTMENT. PARKING GARAGE. PC FOR POWER AND ENERGY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29898	19041-10000-08515	1801 S CENTURY PARK EAST ste. 2000	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.06201	-118.41537	T-24 PC FOR A PARTIAL TI OF 20TH FLOOR OF AN OFFICE BUILDING. SUITE #2000. SCOPE INCLUDE NEW RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 7072 SQ.FT. TOTAL CONNECTED LOAD IS LESS THAN 400AB# 19016-40000-05151	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29899	16041-20001-15354	9132 N SEPULVEDA BLVD	91343	7	198B145   337	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.2368	-118.46732	CJANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 6.  CHANGES INCLUDE LIGHITNG TYPE FIXTURES AND ENERGY CALCS.  PLAN CHECK FOR ENERGY ONLY.  T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (SKECHERS SHOE STORE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 11247 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29900	19041-10000-35240	1707 S WESTERN AVE	90006	10	126B193  1422	5073012033	C2-2D-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			Not Ready to Issue	10/16/2019 12:00:00 AM	ADDRESS	34.04255	-118.30925	"CHANGE OF USE FROM RETAIL TO ""WING STOP"" RESTAURANT. Installing lights, 2 new panels and new circuits. T-24 Energy only. Building Permit: 19016-20000-22455"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29901	18041-20000-42866	5755 N TUJUNGA AVE 1-34	91601	2	174B173   403	2338024019	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			11/08/2018 12:00:00 AM	08/20/2020 12:00:00 AM		Permit Finaled	07/06/2022 12:00:00 AM	ADDRESS	34.17554	-118.3792	1600A 240/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29902	15041-10000-21917	751 E 90TH ST	90002	9	094-5A207  12	6042010014	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	33.95482	-118.26125	PV1.  Install 7.0 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29903	18041-20000-13371	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	33.74512	-118.26099	Plan check for Medium voltage adding temporary standby generators for Water Recolamation Plant with 2 alternatives approch of install genarators(2 alternatives are shown on plan). Add resistive load bank to medium voltage switch gear. All new work has been clouded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29904	12041-10000-27877	6125 N ALCOVE AVE	91606	2	177B161   580	2332032003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Expired	12/15/2014 12:00:00 AM	ADDRESS	34.18177	-118.41277	PV1 4.16KW ROOF-MOUNT ENPHASE MICROINVERTER STANDARD PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29905	19041-10001-34949	19812 W KITTRIDGE ST	91306	3	180B113   382	2134007014	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM			PC Approved	11/20/2019 12:00:00 AM	ADDRESS	34.19095	-118.56483	RELOCATION OF AC DISCONNECT AND COMBINER BOX TO EAST OF PROPERTY. ALL CHANGES HAVE BEEN CLOUDED ONTO DELTA 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29906	10041-10000-09310	1600 N VINE ST	90028	13	148-5A189 346	4307013027	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.1	-118.32647	Existing high rise bldg, two story restaurant. power, lighting and title 24. (( 5 new panels and one 75 kva xfmr    , 65 branch ckts, 2  6k nde , 30k ,75k, 5    100 amps panel and a 200 amps service.  4600 sqft of title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29907	15041-20002-18839	19143 W VICTORY BLVD Bldg 5	91335	3	180B121   534	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	34.18674	-118.55078	VOID. PERMIT FINALED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29908	14041-10000-17249	1550 N EL CENTRO AVE	90028	13	148-5A189 303	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Closed	08/02/2018 12:00:00 AM	ADDRESS	34.09961	-118.32359	fire alarm variance has not been filed.PC FOR POWER AND ENERGY. New High Rise Apartment Building with Future Restaurant and Retail at the Ground Floor. 200  UNITS IN 14 TYPES.see additional comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29909	12041-10000-18048	1250 W HARRY BRIDGES BLVD MAIN EXIT-CANOPY	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	PIN	33.77046453	-118.27163726	PLAN CHECK POWER FOR NEW MAIN EXIT CANOPY WITH LIGHTING FOR MAIN GATE CANOPY.  REAR BERTHS 136-139, MAIN EXIT. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29910	13041-10001-36138	9544 N WYSTONE AVE	91324	12	201B121   709	2762037039	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.24424	-118.54634	Expedited RSES plan check per applicant request.{{PV1, Install 12 kw DC roof-mounted solar array for a two story house, interconnect with main service panel. (2)Transformerless inverter(s): Power- One Aurora PVI-4.2-outd-S-US, (48)Modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29911	16041-20003-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.09822	-118.31812	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET.  ALL CHANGES ARE CLOUDED UNDER DELTA 6, 8, 8.1, & 10. CHANGES INCLUDE REVISING LIGHTING FLOOR PLANS, REVISING TITLE 24 CALCULATIONS, REVISING LOAD CALCULATIONS, PROVIDE TWO CIRCUITS FOR STAIRWAYS, AND REVISING EMERGENCY PHOTOMETRICS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29912	11041-20001-19780	936 S WESTWOOD BLVD #GR936&290	90024	5	135B153   567	4363019902	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			PC Approved	02/22/2012 12:00:00 AM	ADDRESS	34.06291	-118.44513	changes to 11041-200000-19780Plan check T24 Energy/Emergency lighting for UCLA - Care Connect (Suite #GR936 & #290)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29913	11041-10000-12369	6303 N OWENSMOUTH AVE 7TH FLOOR	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	Ti in an office BLDG. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29914	10041-20000-21445	1109 E VERNON AVE	90011	9	112-5A209  57	5115034003	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	10/28/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	ADDRESS	34.00405	-118.25595	PARKING AREA LIGHTING ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29915	18041-20000-38501	5139 N DENSMORE AVE	91436	5	171B141   258	2261015036	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.16317	-118.47782	PV1.  Install 14.3 kW roof mounted grid tied PV system.  (44) modules with 10 and 5 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29916	15041-10000-07110	335 N MARIPOSA AVE APT #2	90004	13	138B197   132	5520025012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Apartment			03/11/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.07733	-118.29968	PV2, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  DWELLING. INTERCONNECT WITH MAIN SERVICE PANEL. (18) MODULES: YINGLI YL250P-29B(1) INVERTER: ABB PV1-3.6-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29917	19041-20000-14859	301 N CAROLWOOD DR	90077	5	141B157    34	4358005017	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Issued	04/25/2019 12:00:00 AM	ADDRESS	34.08337	-118.42821	Plan check for service upgrade for single family dwelling, upgrade service to 1600A 120/208Volt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29918	10041-10000-15089	21301 W VENTURA BLVD	91367	3	171B105    15	2167001019	(T)(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	09/28/2010 12:00:00 AM	PIN	34.16827238	-118.59592564	Install a central station monitoring system in a new building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29919	17041-10001-22261	3525 W 8TH ST	90005	10	132B193   573	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.05782	-118.30714	PLAN CHECK ONLY FOR UNAPPROVED SET. PLAN CHECK FEES ARE PAID UNDER MASTER APPLICATION. MASTER PC EXPIRATION DATE IS 08/28/2019 AFTER THE APPLICANT FILED FOR THE FIRST EXTENTION. ORIGINAL SCOPE :(((((PC FOR POWER AND ENERGY. SERVICE 480/277V 5000A. NEW CONSTRUCTION-SEVEN  STORY TYPE III-A 367??? UNIT APARTMENT BUILDING OVER TWO LEVELS TYPE IA RETAIL/COMMERCIAL/PARKING OVER THREE LEVELS SUBTERRANEAN PARKING.  1 OF 3))))NOTE: PERMIT WILL BE PULLED UNDER MASTER APPLICATION UNDER 17041-10000-22261	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29920	12041-10000-26584	8469 W MELROSE PL	90069	5	141B173   424	5528001055	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.08374	-118.37563	COMMERCIAL TITLE 24 SHELL ONLY.  NEW SERVICE. EQUIPMENT OVER 600A LOAD OVER 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29921	18041-10000-48567	9621 N IRONDALE AVE	91311	12	201B109   260	2748023057	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.24509	-118.58609	NOTE: FEES ARE $0 DUE TO ASSEMBLY BILL 1414PV2. NEW 336.96KWdc / 240KWac ROOF MOUNTED PV SYSTEM WITH 936 PV PANELS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29922	13041-10000-12846	4710 W JANET PL	90041	14	160-5A219 121	5685002023	RE20-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.1348	-118.22224	PV1, roof-mounted system on 2-story house (6.0 kW DC)  {24 modules: Canadian Solar: CS6P-250P}  {Central Inverter: KACO BluePlanet 5002xi}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29923	07041-10004-27323	2321 W 10TH ST 1-27	90006	1	130-5A201  37	5136004014	R4-1	Central	Westlake	MacArthur		2095.10	Electrical	Electrical	Apartment			04/06/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.05327	-118.28254	CHANGES TO THE APPROVED PLANS.  REVISED PANEL SCHEDULE IN THE UNITS AND CHANGES TO THE HOUSE SERVICE.New 27 unit apartment with 2 subterranian parking and 4 levels above grade (6 typical).  New service 1200amp, 120/240v, 1ph, 3w.  Plan check for power and energy.  Note: Filed for conduit variance only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29924	14041-10001-05912	13603 W MARINA POINTE DR	90292	11	105B153    74	4229003066	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Expired	07/12/2016 12:00:00 AM	ADDRESS	33.98559	-118.44433	REPLACING 1 FIREALARM PANEL TYPE EST2 WITH EST3X IN GARAGE LEVEL. SAME MANUFACTURER AND 1  GRAPHIC ANNUNCIATOR PANEL.  ALL DEVICES ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29925	14041-10000-17723	730-736 S LOS ANGELES ST	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.04254	-118.25109	plan check for power and energy. high rise. Existing building. not methane. REMODELED 6-STORIES  72 UNITS APARTMENT BUILDING. BLDG#14016-10-11297:ADAPTIVE REUSE. Changes on plan include updates to load calcs and T24 and address.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29926	15041-10000-12870	1500 W PACIFIC COAST HWY	90744	15	033B201     2	7412009011	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			04/29/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	PC FOR METHANE MITIGATION SYSTEM FOR A RESIDENTIAL APARTMENT COMPLEX, 13 BUILDING. 705 FA DEVICES, 15 CONTROL DEVICES. 2 notes added clarifying vent riser detectors to be accessible from garage and extraction fans are to be located on roof (not the attic).Other buildings will be covered under the following permit #s:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29927	16041-10013-35308	19535 W NORDHOFF ST BLDG  B	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM			PC Approved	08/01/2019 12:00:00 AM	PIN	34.2363795	-118.55851216	CHANGES TO PERMITTED SET OF PLANS-BULLETIN 38ATTACHED TO THE PLANS ARE THE LIST OF CHANGES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
29928	18041-10000-09564	2025 S AVENUE OF THE STARS S. TOWER	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	09/19/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	SEE APP. COMMENTS.PC FOR NEW FA IN HIGH RISE SOUTH TOWERSCOPE INCLUDES 3130   DEVICES AND 50 PANELS. B#15010-10000-02800	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29929	17041-10000-18133	801 S FIGUEROA ST 10TH FLR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Info Complete	05/31/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	REMODEL OF CORRIDOR. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29930	10041-10000-07460	800 E 12TH ST 1-119	90021	9	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	05/03/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	xPRESS PERMIT FOR UNIT  # 412	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29931	16041-20003-44615	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	08-28-2019 Changes to an approved set of plan, Changes include remove lighting fixtures, receptacles and change some lighting all Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29932	16041-30000-23031	1540 S CALZONA ST	90023	5	117A227    46	5192002012	OS-1XL	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.01455	-118.19633	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 33600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29933	13041-10001-35606	11995 W BLUFF CREEK DR BLDG #4	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	33.98218	-118.40255	Changes to approved set; Instead of overhead severice, applicant changes it to underground. There are also minor changes to title 24. Note per F.Y.(((CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  36760 SF WITH NEW SURFACE PARKING LOT. TITLE 24 ENERGY FEE CHARGED UNDER BUILDING 3.  3 TOTAL BUILDINGS.  THIS IS BUILDING 4/5 IN THE SAME PARCELBLDG PERMIT: 13010-10000-04244)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29934	17041-20001-21599	6919 N BIRCHTON AVE	91307	12	183B093   601	2028012025	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.1948	-118.64148	7/17/2018changes to an approved set of plans.  changes to relocate existing equipment and addition of 1 subpanel. (((plan check for power.  addition of back up battery (5.8kw powerwall) to an existing pv syetm.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29935	10041-20000-00423	10635 W SANTA MONICA BLVD s.125	90024	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood			2656.00	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Finaled	03/25/2010 12:00:00 AM	PIN	34.05365874	-118.43036269	s. 125 office t.i.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29936	13041-10000-28362	10901 N KEY WEST AVE	91326	12	210B117   347	2718022030	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.26829	-118.55392	PV1, SOLAR INSTALLATION TO BE INTERCONNECTED WITH 200A MAIN PANEL IN 2-STORY HOUSE. POWER OPTIMIZERS (solaredge #op300-mv) ARE USED. SYSTEM SIZE IS 4 KW DC. 16 MODULES, (1) SOLAREDGE # SE3800A-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29937	19041-30000-26499	5750 W WILSHIRE BLVD STE 655	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Info Complete	07/11/2019 12:00:00 AM	ADDRESS	34.06227	-118.3542	P.C TENANT IMPROVEMENT TO (E) OFFICE IN A HIGH-RISE BUILDING. TOTAL AFFECTED AREA 6,595 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29938	16041-20000-21959	9725 N TUNNEY AVE	91324	12	201B117   333	2761034004	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.24722	-118.55755	PV1(ACM) INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.8KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29939	16041-20001-02682	525 S FLOWER ST 1st Level	90071	14	130-5A209 135	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.05109	-118.25696	Plan check for Title 24 only for existing high-rise building in plaza level and mezzanine. Total area indoor + outdoor: 13,551.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29940	14041-20000-01337	21312 W MULHOLLAND DR	91364	3	162B105    46	2173018002	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Expired	03/23/2016 12:00:00 AM	ADDRESS	34.14373	-118.59754	PV1 TRANSFORMERLESS USING OPTIMIZERS 12.0KWAC. *0$ FEES DUE TO 2012 SENATE BILL 1222*	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29941	15041-10000-10768	1522 S ARMACOST AVE TEMP	90025	11	126B145   548	4263033022	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.04124	-118.45949	NEW FIRE ALARM SYSTEM FOR NEW APARTMENT BUILDING. 108 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29942	16041-20000-41476	1447 N MARTEL AVE SLS#5	90046		147B181  1153	5550021013							Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Plans on Hold	12/02/2016 12:00:00 AM	ADDRESS	34.09728	-118.35102	New 4-story single family dwelling with subterranean attached garage.  Small lot subdivision.  Collective service for (6) new SFDs on same lot.  Plan check for power and energy.  Service equipment, house panel, and energy fees charged on unit #1.  Building permit filed under 16010-10000-02540 et al	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29943	16041-20000-18185	500 S FIGUEROA ST 3rd floor	90071	14	130-5A209 117	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Expired	06/26/2018 12:00:00 AM	ADDRESS	34.05146	-118.25758	Plan check Title 24 only in existing space T.I. Total area: 760 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29944	16041-20000-26844	6400 N LAUREL CANYON BLVD 5th Floor	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.18693	-118.3963	Plan check for Title 24 only. Project site is a tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29945	10041-20000-16400	3494 E PICO BLVD 1 ST FLOOR	90023	14	118-5A225 320	5190036804	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM	08/20/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.0179	-118.20314	revise load on ups removing the panic shut off swich for computer room subject to fire department approval	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29946	18041-20000-39636	4166 N MURIETTA AVE	91423	4	165B153   871	2266024036	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Closed	01/13/2023 12:00:00 AM	ADDRESS	34.14579	-118.43742	Plan check for a PV1 roof-mounted PV system. System size is 11.2 kWdc/10.83 kWac-CEC and consists of (2) inverters, (35) modules, (2) load centers, and (2) PowerWalls.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29947	14041-10000-24996	3475 S CLARINGTON AVE 1-37	90034	5	120B165    64	4313001034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Apartment			09/11/2014 12:00:00 AM			Reviewed by Supervisor	11/05/2014 12:00:00 AM	ADDRESS	34.02859	-118.40528	PV2, INSTALL 23205 W DC ROOF-MOUNTED SOLAR ARRAY ON A APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL.(91) MODULES: CANADIAN SOLAR CS6P-255P(91) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S2X-IG	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29948	15041-10000-35163	9270 W SIERRA MAR DR	90069	4	144B165    84	4392009021	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.09471	-118.39361	PV1. INSTALL 11.04 KW DC ROOF-MOUNTED SOLAR AARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: SUNPOWER X21-345(1) INVERTER: SOLAREDGE SE11400A-US 240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29949	18041-20000-03150	4939 N LOUISE AVE	91316	5	168B133   106	2290001012	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.15959	-118.51001	Plan check for the addition of (2) Tesla PowerWalls onto an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29950	15041-20002-21566	1422 W 223RD ST PV1	90501	15	048B193   688	7347003007	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	33.82438	-118.30231	**PC only***Permit Under 15041-10000-21566((This is PC only for PV1. Applicant has pulled Express permit in downtown under 15041-10000-21566, and then came back to downtown for express permit to upgrade the panel under 15041-10001-21566.Then the inspector told him to come for plan check only))Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.  The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.   (6.72 KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29951	19041-20000-11226	10650 N DE SOTO AVE	91311	12	207B109   345	2706011001	(T)(Q)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.26388	-118.58835	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN EXISTING CHURCH BUILDING. SCOPE OF WORK INCLUDES 1 FA PANEL, AND 49 FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29952	17041-10000-44211	20220 W PLUMMER ST	91311	12	198B113    80	2748038029	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.2426	-118.5736	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29953	11041-20000-18145	12500 W RAYMER ST	91605	2	186B165   579	2324003035	M2-1VL	South Valley	North Hollywood - Valley Village			1233.04	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.20227	-118.40542	PLAN CHECK T24 ENERGY AND EMERGENCY FOR FIRE DAMAGED EXISTING MFG/WHS. PERMIT FOR NEW 400A SERVICE AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29954	15041-20000-10598	6250 W HOLLYWOOD BLVD SUITE 100	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.10133	-118.32547	PC FOR T24 ENERGY ONLY. TI TO A BAR. SOME NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29955	14041-10000-32762	231 W C ST	90744	15	027B205   128	7418022009	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.77272	-118.26419	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 12785 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29956	19041-10000-24596	8520 W VENICE BLVD	90034	10	123B173   453	5065007021	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	08/16/2022 12:00:00 AM		Permit Finaled	03/23/2023 12:00:00 AM	ADDRESS	34.03435	-118.37888	T-24 PLAN CHECK FOR A NEW 2-STORY COMMERCIAL OFFICE & RETAIL BUILDING. SCOPE INCLUDES NEW 400A SERVICE & EQUIPMENT. TOTAL AFECTED AREA IS 7,902 SQ.FTALL ELECTRICAL EQUIPMENT (INCLUDING CAR LIFTS SHALL BE LISTED BY AN AUTHORIZED AGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29957	15041-10000-01167	6944 S KNOWLTON PL	90045	11	102B173   375	4103013008	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	33.97371	-118.37115	Regular plan check for power and energy. Project is a new 4-story, 36-unit multi-dwelling building with a grade level parking garage. There are 3 typical units. Total lighting area = 21,000 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29958	13041-20001-31668	8917 N RESEDA BLVD	91324	12	195B125   372	2770005015	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.23242	-118.53628	((CHANGES MADE TO APPROVED SET OF PLANS. CHANGED A COUPLE OF CRKTS TO GFCI AND EM LIGHTS DAMP LOCATION))T24 FOR EXISTING SWIMMING SCHOOL. TOTAL NEW LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29959	18041-20001-05921	315 S JUNE ST	90020	4	135B185   127	5507001013	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.06832	-118.33435	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 16.6 kWac and consists of (52) AC PV modules and (2) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29960	18041-10000-21861	16951 W ESQUIRA PL	91436	5	168B133   505	2289031008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.15345	-118.50265	Permit fee is $0.00 due to Senate Bill 1222.16.3 (DC) KW PV SYSTEM, WITH 50PV MODULES & 2 INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29961	17041-10001-20749	1575 N GOWER ST 150	90028	13	148-5A189 330	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	PER INSPECTIONPC FOR POWER SYSTEM FOR FIRST TIME TENANT. ADDED TI-24 POWER DIST. SYSTEM COPLIANCE SEC.130.5PERMIT PULLED UNDER TI-24 PLAN (MASTER). ****************************************************PC FOR TI FOR AN OFFICE (HIGH RISE) TITLE- 24 ENERGY ONLY.  NEW LIGHTS RECEPTACLES CIRCUITS AND ONE PANEL. TOTAL AFFECTED AREA 4426 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29962	14041-10003-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/29/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	33.95637	-118.3838	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS. CHANGE TO SERVICE POINT. SERVICE FOR ALL BUILDINGS NOW FROM SINGLE 5000A SERIVCE POINT. PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29963	17041-10000-35990	20830 W SHERMAN WAY	91306	3	183B109    77	2137020039	CR-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.20086	-118.58705	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29964	15041-10000-04273	159 E MANCHESTER AVE	90003	9	097-5A205 319	6030017016	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	33.96026	-118.27184	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL  AREA 2816 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29965	15041-10000-22304	11900 W OLYMPIC BLVD #410	90064	11	123B149   541	4259024003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.03252	-118.45186	Tenant improvement to (E) 4,060 sq. ft. commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29966	11041-10000-08433	3939 S FIGUEROA ST	90037	8	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.01173	-118.28296	POWER FOR NEW SCORE BOARD INSIDE/ FACING OUTSIDE OF THE USC COLLESEUM   FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29967	11041-20007-03572	350 S MAIN ST BLDG C	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM			PC Approved	11/15/2011 12:00:00 AM	ADDRESS	33.99499	-118.47656	DELTA 11 REVISION TO APPROVED PLANS. CHANGES TO T24 CALCULATION AND BRANCH CKTS.  BUILDING WERE PLAN CHECKED UNDER APPLICATION 11041-10000- 03572.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29968	19041-10001-33940	3905 S KEESHEN DR	90066	11	111B157   132	4235025023	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM			PC Approved	09/09/2019 12:00:00 AM	ADDRESS	34.00382	-118.42828	PLAN CHECK ONLY. CHANGES TO APPROVED SET. CHANGING MICROINVERTERS TYPE FROM IQ-6PLUS TO IQ-7PLUS. SYSTEM SIZE IS UPDATED TO 5.8KWac(((Plan check for a PV1 7.1KW DC / 4.8KW AC roofmounted system with (1) load center,  (20) Enphase Microinverters and modules interconnecting through the main service panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29969	17041-10000-05999	526 S ALAMEDA ST	90013	14	126A215    90	5163027017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM			PC Approved	02/24/2017 12:00:00 AM	ADDRESS	34.04057	-118.23803	Plan check for Title 24 only in existing space, Office T.I. Total area: 1,762 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29970	13041-10000-13765	219 E WINSTON ST	90013	9	129A213   299	5148007006	C2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.04626	-118.24644	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING IN AN EXISTING WAREHOUSE AND RETAI SPACE.  SCOPE OF WORK < 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29971	17041-10001-46473	1851 S WOOSTER ST	90035	10	126B169   162	4303007028	R1R3-RG	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.04471	-118.3846	PC FOR CHANGES TO APPROVED TO REFLECT FIELD INSTALLATION. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER. SET PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (200A), 2 BATTERIES RATED AT 11.6KWac WITH EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29972	10041-10000-25736	325 W ADAMS BLVD	90007	9	123A205   197	5126018035	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Closed	11/16/2012 12:00:00 AM	ADDRESS	34.02712	-118.27319	3 LEVEL OF UNDERGROUND PARKING STRUCTURE TO PROVIDE PARKING SPACE FOR AN EXISTING DETACHED MEDICAL OFFICE BLDG AT 2400 S. FLOWER ST AND 5 LEVELS OF RESIDENTIAL BUILDING ABOVE. THIS STRUCTURE WILL PROVIDE 483 STALLS WITH 216,878 SF.  INCLUDE A 4160 V, 1000 AMP SERVICE FOR THE PARKING STRUCTURE AND FUTURE RETAIL STORES. Plan Check is for Power & Energy.   (EPC # 10041-10000-25737 & Bldg PC# 10010-10000-01203)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29973	13041-10000-18939	1122 S GAYLEY AVE	90024	5	132B149   112	4363023030	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			07/17/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.05976	-118.44586	pc for power and energy. Methane Buffer Zone. fire alarm variance to be filed. MIXED USE PROJECT- 34 UNIT APARTMENT, RETAIL AND PARKING GARAGE. THE 2 BASEMENT LEVELS ARE OF TYPE I CONSTRUCTION W/ PARKING, THE 1ST STORY IS OF TYPE I CONSTRUCTION RETAIL/ENTRY TO RESIDENTIAL UNITS AND OFFICE ACCESSORY TO  RESIDENTIAL, STORIES 2-4 ARE RESIDENTIAL UNITS OF TYPE IIIA CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29974	18041-20000-19607	11239 W VENTURA BLVD #105	91604	2	162B173   294	2366035036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.14181	-118.37523	Plan check for Title 24 Energy only in existing retail space T.I. new lighting Total area: 4,832 sq ft.B#18016-20000-16693	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29975	16041-10001-37452	1107 W 185TH ST	90248	15	060B197   122	6109021012	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	33.86282	-118.29303	Expedited RSES plan check per applicant request.<<<<PV1 roof mounted solar system installation to a singe family home. Installing 40 modules: sunpower SPR327NE-WHT-D and 2 inverters: solaredge SE7600 and 3000A-US>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29976	13041-10000-18840	523 W 6TH ST SUITE 610	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	OFFICE TI, TENANT LIGHTING SYSTEM, ADDITION OF RECEPTACLES IN HIGH-RISE BUILDING. TITLE 24 PLAN CHECK ONLY, PERMIT TO BE ISSUED AT THE ELECTRICAL PLAN CHECK COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29977	11041-20000-21927	1250 N CAPRI DR	90049	11	129B133    73	4407014005	A1-1XL, R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	PIN	34.04999474	-118.49995246	Per Inspector's request, Title 24 plan check only.  Remodel of light fixtures in the lounge/banquet room.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29978	13041-10003-05747	380 WORLD WAY Space T64	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES IN THE T24 ONLY, REPLACING TYPE 100A AND LF-05 LUMINAIRE TO BE ETL APPROVED LUMINARIES PER INSPECTORS REQUEST.supplemental 2: changes to approved plans: adding ckt 4T-64:26 for 4 receptacles. floor plan E2.1 and SLD updated under delta 15supplemental 1: shows more detail about the location of  partial fourth floor storage room electrical plan. also shows that kitchen table/counter actually includes a load center. PROPOSED 803 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Scoreboard LA).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29979	12041-10000-09661	9575 N REVERIE ROAD	91042	2	201A199   296	2562019003	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	34.24347	-118.29113	Plan check for installation of 7.92KW roof mounted photovoltaic system. single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29980	12041-20001-29542	9200 N OAKDALE AVE	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM			PC Approved	12/14/2012 12:00:00 AM	ADDRESS	34.23811	-118.56674	energy plan check office emergency lighting existing to remain and not a part of this plan check.  (Change of lighting from previously approved set of plans)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29981	11041-20000-26967	550 S MAPLETON DR	90024	5	138B157    56	4359013028	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2011 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.07442	-118.42882	New 11.04 KW roof mounted PV system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29982	14041-10000-08426	1735 N LA BREA AVE 1-18	90046	4	147B181  1211		R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.10267	-118.34589	T24 FOR LOBBY AREA OF APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29983	14041-20001-24073	23723 W SANDALWOOD ST	91307	12	186B093   315	2027017018	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM			PC Approved	09/08/2014 12:00:00 AM	ADDRESS	34.20561	-118.64344	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 8.8kW.(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(36) Trina solar TSM-255PA05.18 pv modules(36) SolarEdge P300 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29984	17041-10000-09758	6240 N LANKERSHIM BLVD	91606	2	177B169   177	2335029901	R3-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.18433	-118.38614	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 21288 SQ. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29985	10041-20000-15183	20907 W SHERMAN WAY	91303	3	183B109    57	2112017001	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	01/24/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.20126	-118.58882	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT -  CHANGE OF USE FROM (E) RESTAURANT TO (N) TAKE-OUT RESTAURANT - LITTLE CAESAR. ***PERMIT SHALL NOT BE ISSUED BEFORE BUILDING (LANDLORD) SERVICE UPGRADE HAS BEEN APPROVED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
29986	09041-10001-06448	7630 N VAN NUYS BLVD	91405	6	186B149   111	2215028021	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	03/12/2010 12:00:00 AM		Permit Closed	11/05/2010 12:00:00 AM	ADDRESS	34.20936	-118.44853	Revision to the electrical and lighting system for a new Bakery and Restaurant building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29987	12041-10000-07760	3121 N GLENDALE BLVD	90039	13	154-5A207 352	5435027014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM			PC Approved	04/04/2012 12:00:00 AM	ADDRESS	34.11664	-118.26268	retail space changed to Boba Drink/soda storeplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29988	15041-20000-14806	1100 W WILSHIRE BLVD #104	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.05228	-118.26384	Title 24 plan check only.  Total area =  2,898 sq. ft. T.I. to existing commercial highrise office space.  3 new panels supplying lighting, HVAC, and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29989	13041-10000-08108	19807 W GILMORE ST	91367	3	180B113   729	2134027002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.1876	-118.56473	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.29KW. USING 42 MODULES AND CENTRAL INVERTER. STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29990	18041-20000-48372	2000 S AVENUE OF THE STARS	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	Lighting and power for new interconnecting stairs between 8th and 9th floors.  Plan check for Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29991	15041-20001-08141	7200 W FOOTHILL BLVD #102	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.24842	-118.28878	Changes to approved set.  Changes to type of lighting and layout.  Plan check for T-24 only for yogurt shop. Total area: 963 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29992	15041-10001-26544	633 W 5TH ST	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	04/07/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	changes to approved set	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29993	15041-10000-06155	10149 N BARTEE AVE	91331	6	204B153   610	2645012006	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.25467	-118.43675	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 804KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29994	14041-10000-02362	2806 N GLENDOWER AVE	90027	4	153B197   127	5588011007	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	34.11598	-118.2964	PV1, Install 3.98 KW DC roof-mounted solar array on a three story house, interconnect with existing service panel. (1)Transformerless inverter: POWER-ONE AURORA PVI-3.0-OUTD-S-US(15) Modules: SUNIVA OPT265-60-4-1B0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
29995	18041-10000-46731	11525 W CHANDLER BLVD	91601	2	171B169    59	2350010019	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.16877	-118.38311	Install  new Fire Alarm system for new 60 unit four story apartment with one level of subterrenean parking. (1) FACP, (2) RPS, (101) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29996	19041-10000-41712	5058 N WILLOW CREST AVE	91601	2	171B177   998	2419015001	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.1629	-118.36253	[EPLAN] PLAN CHECK FO ROOF MOUNTED 11.655 PV1 SYSTEM CONSISTING OF 37 modules with 37 microinverters(IQ7X-96-2-US) MAIN BREAKER DERATE UNDER SEPARATE PERMIT$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29997	18041-10001-37551	8552 N GLENCREST DR	91352	2	192B177    79	2404011022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	11/21/2018 12:00:00 AM	ADDRESS	34.22608	-118.36096	CHANGES TO AN APPROVED SET. PC ONLY FOR COMPLIANCE AFTER A PANEL UPGRADE FROM 125A TO 200A. ALL CHANGES ARE CLOUDED UNDER DELTA 1. ***PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.60KWdc / 6.00KWac. (24)MODULES- CANADIAN SOLAR CS6K-275P (24)OPTIMIZERS-SOLARDGE P320 OPTIMIZERS(1)INVERTERS-SOLAREDGE SE6000H-US***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
29998	15041-20000-04451	5835 N OAKDALE AVE	91367	3	174B113    59	2153016028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.17678	-118.56582	PV1MICROINVERTER STANDARD PLAN SYSTEM SIZE 6.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
29999	19041-20001-05375	4947 W LOS FELIZ BLVD	90027	4	150B197   119	5588009004	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.11031	-118.29732	Expedite per applicant request Plan check for PV roof mounted and Battery system, PV system size: 10.7KW DC, 10.6KW AC with 37 PV Modules and 2 inverters(7.6KW and 3.0KW) and 1 LG Battery RESU 9.8KWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30000	17041-10000-34261	1120 W WASHINGTON BLVD	90015	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	PIN	34.03794253	-118.28208997	PC FOR A  FIRE ALARM SYSTEM, TI PORTION OF  NEW 4 STORY MEDICAL OFFICE BUILDING. PROJECT CONSIST OF 303 DEVICES. SOME PANELS AND FEW DEVICES ALREADY APPROVED UNDER CORE AND SHELL PCIS#17041-10000-27248Building application number: 16010-10000-03992	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30001	17041-10000-06760	1101 S VERMONT AVE #102	90006	1	129B197   480	5078027037	C2-1, R4-1VL	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.05073	-118.29194	T-24, PC FOR ENEGY ONLY. T.I. FOR EXISTING RESTAURANT TO REMODEL DINING AREA, SUSHI BAR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2745 SQ. FT.   ALL WORK PER ENGINEERING PLANS.  A-OCCUPANT LOAD < 100. b#17016-10000-04693	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30002	11041-20000-13095	1115 S ALVARADO ST	90006	1	129A201    14	5136018902	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.04969	-118.28139	Plan check power and energy relocated 2 historic building with common basement and connecting tunnel. New 600A service, panels, ckts, and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30003	15041-20000-29568	15541 W LEMAY ST	91406	6	180B141   206	2234004023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.1913	-118.47323	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30004	19041-20000-29990	13003 W VENTURA BLVD UNIT D & E	91604	2	165B161   966	2375022103	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	NEW FIRE ALARM SYSTEM IN EXISTING RETAIL STRIP MALL FOR UNITS D AND E. SCOPE OF WORK CONSISTS OF (15) FIRE ALARM DEVICES AND A FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30005	15041-10000-01076	12518 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	33.97836	-118.41209	Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30006	18041-10000-47228	5910 W PICO BLVD	90035	10	129B173   438	5068017005	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.05157	-118.36791	REMOVE HID INDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30007	11041-20000-14654	11766 W WILSHIRE BLVD #1600	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			PC Approved	07/14/2011 12:00:00 AM	ADDRESS	34.04804	-118.46227	PLAN CHECK T24 GENERAL/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT ON THE 16TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30008	14041-20000-19948	6201 W HOLLYWOOD BLVD SUITE 128	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	TI, new lighting. Juicery. PC for T24 energy only. per building submittal, PC for 2013 building efficiency standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30009	13041-20000-12162	515 S FLOWER ST flr 26	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.05134	-118.25661	T24 FOR CONFERENCE ROOM ON THE 26TH FLOOR ROOM 2609. 489 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30010	19041-20000-52363	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	04/12/2024 12:00:00 AM		Issued	04/12/2024 12:00:00 AM	ADDRESS	34.10191	-118.28217	Replacement of 4.16 kV-208Y/120V 3ph-4w unit substation and other distribution equipment.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30011	16041-10001-15692	12602 W VENTURA BLVD	91604	2	162B161   146	2384022024	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	34.14333	-118.40789	Revision to approved set, this is PC only, permit will be issued under master E#.Changes on floor plan and light fixtures, adding controlled receptacles in the private office and conference room. Total area remain the same.<<CHANGE OF USE  OF A PORTION OF AN EXISTING RETAIL BUILDING TO A PHARMACY AND AN INTERIOR TI. USE (E) CIRCUITS, PC FOR T-24 (lighting only, no new receptacles). TOTAL AREA: 2,280 SQ.FT>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30012	13041-10001-21428	1245 W WILSHIRE BLVD 1ST FLOOR	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.05373	-118.26606	Plan check Delta 5 revision. Minor changes to circuitry. No permit to be issues. Plan check only. RADIATION ONCOLOGY ON FIRST FLOOR OF HIGH RISE MEDICAL OFFICE BUILDING. PLAN CHECK POWER & ENERGY INCLUDING OSHPD 3 REQUIREMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30013	15041-10001-21823	1808 S CARMONA AVE UNIT 2	90019	10	126B177   903	5064010010	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.04106	-118.36071	EXPEDITED FEES FOR SOLAR ROOF MOUNTED SYSTEM. (((PV2, ROOF MOUNTED SOLAR, 2.6 KW PV ARRAY.(1)INVERTER: PVI-3.0-OUTD-S-US-Z-A(10)MODULES: KU2606XPA)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30014	17041-10001-46263	10561 N HORSE CREEK AVE	91040	7	207B177   243	2528035015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.26185	-118.36175	**Zero plan check fee per Senate Bill 1222**[This is plan check only, permit is covered under master] Revision to approved plan, scope includes:(1) To indicate AC system to be 9.6 kW AC STC on the Project Information (PV-1)(2) To remove the LADWP performance meter on the site plan and single line due to system being under 10kW AC.(3) Relocate AC disconnect to the other side of wall on site plan.All other remain the same.<<Install New PV1 rooftop on an (E) SFD. (30) AC modules SPR-X21-345-S-ACW, system 10.35kW AC.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30015	18041-20000-44219	1105 S SHERBOURNE DR 1-6	90035	5	132B169   467	4332022020	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			11/19/2018 12:00:00 AM			Plans on Hold	12/18/2018 12:00:00 AM	ADDRESS	34.05692	-118.3796	NEW 8 UNIT APARTMENT COMPLEX. SCOPE INCLUDES NEW SERVICE (600A  240/120 3PHASE 4W). TOTAL AFFETED AREA IS 8400 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30016	14041-20001-01896	6057 N CARTWRIGHT AVE	91606	2	177B177   457	2414014001	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.18104	-118.36389	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30017	19041-10000-43953	12105 W WATERFRONT DR	90094	11	105B161  1195	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	08/09/2020 12:00:00 AM	ADDRESS	33.98095	-118.40764	Power plan check for adding a new section  containing a 600A  and a 200A  OCPDs  to an existing 5000A, 480/277,3Ph, 4 wire service switchboard. 600A is connected to a load provided by others. 200A for future tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30018	12041-10000-27842	6234 N GOODLAND PL	91606	2	177B161   256	2332007017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.18403	-118.41101	PV1 ROOF MOUNTED SOLAR INSTALLATION 3.43 KW. ENPHASE 215 MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30019	16041-10000-22043	8825 S SEPULVEDA BLVD	90045	11	096B165   990	4122035027	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM			Corrections Issued	06/22/2016 12:00:00 AM	ADDRESS	33.9565	-118.39648	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING GROCERY STORE TO CREATE A NEW ONLINE ORDERING FOOD STORAGE ARE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 855 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30020	15041-20000-35578	8100 N LIMERICK AVE	91306	3	189B109   195	2108004007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.21698	-118.58258	PV1 SFD TOTAL SYSTEM SIZE 7.6 KW AC USING CENTRAL INVERTER SYSTEM. USING TOTAL OF 31 MODULES. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30021	11041-10000-23844	872 N VIA DE LA PAZ	90272	11	129B125   634	4412003003	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.02	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.04679	-118.52701	change of use to restaurant/yogurt shopplan chk is for title 24 onlyNOTE MAY REQUIRE COMPLETE PLAN CHK AS NEW LOAD IS NEAR 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30022	08041-10002-22171	448 S HILL ST 6th floor	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			Corrections Issued	09/08/2011 12:00:00 AM	ADDRESS	34.04896	-118.25139	This is an AS BUILT aplication.  Work was done under a permit under 08041-10000-22171 that has since expired.  Applicant has included the original approved set of plans. <<<<<New work on the 6th floor.  A variance to separate the electrical and fire life safety system was submitted.  Electrical plan check is for Power, emergency lighting and T24 lighting.>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30023	13041-10000-25103	12105 W BLUFF CREEK DR	90094	11	105B165   936	4211010103	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	33.97901	-118.40436	INSTALLING NEW FIRE ALARM SYSTEM FOR A 2-STORY(+BASEMENT) CORE AND SHELL COMMERCIAL BUILDING. FULLY SPRINKLERED SYSTEM. DURING PLAN CHECKING PROCESS,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30024	18041-20000-32503	8420 N BALBOA BLVD ste 114	91406	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.22384	-118.50243	first time tenant.  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30025	13041-30001-35067	6960 S CENTINELA AVE	90230	11	105B165   480	4220014057	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	33.9837	-118.39937	10-09-2018 Changes to an permitted set of plans. Changes include addition of daylight control in small restaurant, 2nd floor, 3rd floor, mezzanine. All changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30026	19041-20000-44354	21240 W BURBANK BLVD BLDG 30	91367	3	174B105    91	2149016028	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.17307	-118.59314	TENANT IMPROVEMENT ADD NEW LIGHTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30027	16041-10000-19293	3013 E ASBURY ST	90065	1	147A217    79	5454031026	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.09855	-118.23019	PV1, INSTALL 4.578 KW DC / 5.00KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER SPR-327-NE-WHT-D(1) INVERTR: SMA AMERICA SB5000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30028	11041-10000-08186	6144 W 98TH ST	90045	11	090B169     3	4124030900	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	33.94715	-118.39295	Title 24 for a car wax.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30029	12041-10001-07193	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM			PC Info Complete	01/03/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	DELTA 4 CHANGES TO THE APPROVED PLANS.  (REDUCED LOAD) PLAN CHECK ONLY. PERMIT WAS ISSUED 12041-10000-07193. <<<Existing commercial building.  New 3000A service, new panels, equipment, circuits, in a 5-story 90,778 sq ft building.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30030	17041-10000-34304	7808 N FAUST AVE	91304	12	189B097   889	2013029018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.21222	-118.62026	PV1 3.48KW roof mounted system with (12) panels and microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30031	14041-10000-03534	1000 W ELYSIAN PARK AVE outdoor-pavilion	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	plan check for title 24 part 6 energy for outdoor lighting installition in dodger stadiums left and right field landscape, pavilion areas. scope of work is < 400 amp, shown by notes 1 and notes 2 of the panel schedules. other loads were already charged  and plan checked under the reference numbers listed below. Projected area in lighting scope of work is approx, 133,307 sq of outdoor lighting.Reference Plans: 13041-10000-33114 13041-10000-33117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30032	16041-20000-32294	21600 W OXNARD ST 7TH FLR	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.179	-118.6002	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNV NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR POWER AND EM LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 1273.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30033	14041-20000-34630	21600 W OXNARD ST 5TH FLR	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.179	-118.6002	PC FOR T24 ENERGY ONLY. TI TO SUITE 500. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30034	10041-20000-03864	15760 W VENTURA BLVD 9th fl.	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	04/22/2010 12:00:00 AM	ADDRESS	34.1552	-118.47684	Hallway lightingEnergy, exit signsFire Alarm system is by other 10041-10000-03540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30035	12041-10000-30092	2914 W 8TH ST	90005	1	132B197   497	5077023015	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			12/13/2012 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.05751	-118.28966	PV2:  New 47.683 KW AC roof mounted PV system for a multy family dwelling.  224 modules, 2 combiner boxes, 1 inverte (intergtrated transformer). Plans have not been stamped applicant to clear zoning and CRA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30036	10041-20000-03515	7957 N LINDLEY AVE	91335	12	189B125   395	2102014054	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM			Corrections Issued	04/02/2010 12:00:00 AM	ADDRESS	34.21538	-118.52753	T. I WORK IN COMMERCIAL PLACE PLACE ( IN SCHOOL FOR BLINDS) DOING LIGHTING AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30037	14041-10001-23116	138-140 N SAN FERNANDO ROAD	90031	1	139-5A219 122	5447014024	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.07531	-118.22164	Change to approved set by rerouting feeder for panel P2 with new location. All changes are under delta-3 and 4 only.(((PC for power. Upgrading  existing  service  to 800 amp 120/240v 3 phase.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30038	12041-10001-10648	2970 W OLYMPIC BLVD #304	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM			PC Approved	09/07/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	REVISED SHEET E-3 TO SHOW THAT PANEL SERVING THAT FLOOR LIGHTING SYSTEM IS PANEL 305A AND UPDATED THE LOADS SUPPLIED FROM THAT PANELPlan check power and energy for new medical office, first-time tenant. Suite #304. Not check for OSHPD 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30039	16041-20000-03447	9871 N SAN FERNANDO ROAD	91331	7	201B165    79	2624020028	M1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.24947	-118.40499	Plan check for power and energy.  1 story masonry block building 23279 sf  (8) units S-1 occupancy, (4) units F-1 occupancy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30040	17041-10000-41823	9665 N VENA AVE	91331	6	201B157   613	2621031015	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.24581	-118.42585	PC FOR  ROOFMOUNTED PV ON SFD. SYSTEM SIZE 10.08KWACSCOPE INCLUDES 28 AC MODULES AND NEW LOAD CENTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30041	14041-10000-08301	21021 W ERWIN ST 1-395	91367	3	177B109   230		WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			04/01/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Issued	06/02/2014 12:00:00 AM	ADDRESS	34.18304	-118.59175	NEW FIRE ALARM SYSTEM. apt complex with 5 bldgs? 7 stories?	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30042	18041-10000-48270	2140 E 7TH PL	90021	14	124-5A217 350	5166003006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	09/17/2020 12:00:00 AM		Issued	09/17/2020 12:00:00 AM	ADDRESS	34.03337	-118.22846	Service upgrade to 800 Amps. There are no connected loads at this time.Future TI's require Plan Check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30043	16041-30000-23032	2525 E 25TH ST	90058	5	117A219   131	5168021004	OS-1XL	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.0154	-118.22714	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 19800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30044	13041-20001-27740	4650 N BELLAIRE AVE	91604	2	168B161   667	2362024002	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.15545	-118.40928	(((EXPEDITE FEES)))PV1 7.5KW SYSTEM. 3 STRINGS FOR 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30045	15041-20001-21810	8379 N SALE AVE	91304	12	192B097   240	2004004011	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.22217	-118.61948	Expedite fees.Installation of new roof mounted solar PV array.  Total system size = 11 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30046	12041-10000-12326	189 S THE GROVE DR 349	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	Plan check for energy only. 6924 conditioned sqft. 2 story Nordstroms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30047	13041-20000-31169	10421 N AMBERWOOD LANE	91326	12	207B121   815	2728031006	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.26024	-118.54429	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 7.344KW. 34 MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30048	14041-10000-01058	1458 S SAN PEDRO ST #116	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in a retail space.   Plan check only for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30049	16041-10001-14571	1616 W 209TH ST #1	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	33.84074	-118.3073	06/14/16Changes to an approved set of plans. Changes include reducing the number of modules on the roof from 10 to 7 modules, and replacing the inverter from a solaredge #SE3000a-us to an ABB# pvi-3.0-outd-sz-a.  All changes are clouded. address is actually for unit 1, not unit 3. NOTE: permit is pulled under PCIS#16041-10000-14571(((((PV1 INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A MULTI-FAMILY HOUSE.(10) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER:SOLAREDGE SE3000A-US-ZB-U	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30050	16041-10001-09092	900 W WILSHIRE BLVD 72nd floor	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM			PC Approved	09/28/2016 12:00:00 AM	ADDRESS	34.05001	-118.25963	09/28/2016 Changes to an approved set of plans. Changes include different lighting fixture type and layout in Elevator lobby and connect junction box to the disconnect on delta 3. Changes apply to delta 3. only  (((((First time tenant. Full PC to a multi used high rise building hotel/restaurant (73 floors total). Scope of work is being done in the 72nd floor. Total sq ft =7000 )))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30051	16041-20001-01245	5310 N DAHLIA DR	90041	14	163-5A227  48	5669011023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	34.14391	-118.19967	Expedite per applicant request.{{{{{{{Plan check for PV roof mounted system. System size: 6.0kW with 22 modules connected to 200A panel.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30052	18041-10000-40347	2908 S VERMONT AVE	90007	9	120B197   215	5055010041	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.02812	-118.29134	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30053	17041-10000-30879	1215 E WHOLESALE ST	90021	14	124-5A215  10	5164010005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.03668	-118.23791	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURE T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30054	18041-20000-30279	1812 N MELHILL WAY	90049	11	135B133    58	4432011006	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.06764	-118.50063	Plan check for battery back up system Tesla PowerWall 2.0 13.5kWh to existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30055	15041-20000-18154	7647 N ETON AVE	91304	3	186B105    68	2109031004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.20959	-118.59573	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (23) LG280 Modules(1) PVI-6000 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30056	17041-20000-42740	5812 E TIPTON WAY	90042	14	159A229   259	5480011010	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.12947	-118.19178	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 3 kWac and consists of (14) modules, (1) inverter, (1) load center, and (1) battery unit. MSP is center-fed.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30057	14041-10000-32435	100 W 5TH ST	90731	15	018B201   822	7455027933	PF-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	33.74066	-118.28033	New fire alarm and mass notification system for single story boys and girls club building.  (N) FACP with 189 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30058	18041-20000-37018	10920 N GOTHIC AVE	91344	12	210B137   813	2680019022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Issued	09/27/2018 12:00:00 AM	PIN	34.26895864	-118.48887673	Plan check for PV roof mounted system, system size: 9.21KW AC CEC with 21 PV modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30059	17041-10000-17981	5670 W WILSHIRE BLVD 9TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	PC for T24 only for TI in office space with total of 11924 sqft. PC for lights and receptacles. Total load under 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30060	19041-10000-15398	4700 S CENTRAL AVE	90011	9	112-5A209 316	5107016025	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.00099	-118.25628	Remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30061	19041-10000-52887	3410 W 3RD ST EV1	90020	13	135B197   183	5501024028	(Q)P-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	02/18/2021 12:00:00 AM		Permit Finaled	05/19/2021 12:00:00 AM	ADDRESS	34.06884	-118.29027	INSTALLING A NEW 1600 AMP SERVICE, 4 @ 150KW EV CHARGERS, PANELS AND OTHER LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30062	15041-20000-40185	20801 W VENTURA BLVD	91364	3	171B109    62	2166033045	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.16663	-118.58589	TI to existing commercial building (Target) Retail/restaurant. Plan check for energy only. Adding new lighting. Total sqft. 5,363.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30063	15041-20001-02797	12473 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.97916	-118.41034	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30064	14041-10000-17693	5767 W CENTURY BLVD # 4050	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	33.94572	-118.38294	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR A LOW RISE COMMERCIAL BUILDING. Low rise (4 story building) with exit signs on generator and unit equipment. BUILDING P# 14016-10000-12829   T.I. FOR NEW OFFICES, PARTITIONS & RESTROOM UPGRADES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30065	19041-10000-44284	8042 N SHADYGLADE AVE	91605	2	189B165   291	2309007018	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.21709	-118.40184	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 19 MODULES (Q-CELL 285W) , 19 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 5.41KWdc and 3.8KWacCOMPLY WITH DEPARTMENT ORDER effective date05/29/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30066	18041-20000-01705	1539 W 214TH ST	90501	15	051B193   538	7349018028	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	33.8346	-118.30519	INSTALLATION OF AN ENERGY STORAGE SYTEM. 13.5KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30067	15041-30001-33057	350 S GRAND AVE Suite 3950	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM			PC Approved	11/10/2015 12:00:00 AM	PIN	34.05160512	-118.25169569	Changes to approved set.  Remove some track lighting and change a private office to open office.  Addition of small huddle room.Plan check for Title 24 only. Project site is a suite on the 39th floor of an existing, commercial high-rise building. Total lighting area = 4,370 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30068	14041-10000-07059	1616 N LA BREA AVE	90028	13	147B181   377	5548012046	(Q)RAS4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			03/17/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.1002	-118.34456	FA FOR 56 UNIT APT 4 STORIES. 1 facp and 1 annunciator with 141 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30069	11041-10000-12775	400 W WORLD WAY WEST TERMINAL-# 5	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/06/2011 12:00:00 AM	PIN	33.94386803	-118.39979044	REPLACEMENT OF 5 ELEVATORS IN TERMINAL 5 AT LAXPLAN CHK IS REQUESTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30070	14041-10000-11008	10861 W WEYBURN AVE Ralphs	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.06247	-118.44344	PLAN CHECK FOR POWER AND ENERGY FOR EXPANSION OF EXISTING RALPHS STORE. STARBUCKS IS INCLUDED WITHIN THE SCOPE OF THIS WORK. FEES CALCULATED PER APPLICANT. TO BE VERIFIED DURING PLAN CHECK. STARBUCKS TO BE PART OF SCOPE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30071	11041-10000-24199	9601 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/10/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	34.24501	-118.59876	Install food packaging equipment. P/check per applicant's request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30072	18041-10000-30549	6555 W BARTON AVE	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.08785	-118.33475	FULL PLAN CHECK FOR A FIRST TIME TENANT, NEWLY CONNECTED LOAD > 400AMPS. SCOPE OF WORK INCLUDES NEW CIRCUITS AND LIGHITNG IN THE 3RD AND 4TH FLOOR OF A LOW RISE BUILDING. TOTAL SQ. FT. 41316.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30073	15041-20000-42190	3743 S LA SALLE AVE	90018	8	117B193   388	5041033020	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.01931	-118.30521	Plan check for PV roof mounted system. System size: 2.15 kWac  with 10 modules and 10 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30074	12041-10000-05854	515 S FIGUEROA ST # 750	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM			PC Approved	03/14/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR SUITE #750 TENANT IMPROVEMENT. IN HIGH RISE BUILDING.Note: Permit issued under 12041-20000-05996	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30075	13041-10000-35257	1119 E 8TH ST	90021	14	124-5A213 330	5146003054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.03514	-118.24489	SERVICE UPGRADE TO NEW OVERHEAD 800A SERVICE IN (E) COMMERCIAL SINGLE-STORY BUILDING. (5) NEW PANELS TO BE REPLACED. LIGHTING NOT IN SCOPE OF WORK.NOTE: EXISTING PERMIT PER APPLICANT; APPLICANT WILL RETURN WITH PERMIT # UPON RETURN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30076	14041-10000-24407	10630 W SANTA MONICA BLVD 2nd	90025	5	129B157   188	4321003017	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.05279	-118.4303	Medical office required power and energy plan check.  customer reconfiguring offices in the building including lighting and receptical outlets for home dialysis training in partial area of the medical building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30077	14041-20000-22905	10100 W SANTA MONICA BLVD 6th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM			PC Approved	08/22/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI to (E) commercial office space in highrise commercial office building.  Plan check for Title 24 for changes to lighting system in corridor and  conference room only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30078	19041-10000-32991	6432 W SANTA MONICA BLVD	90038	13	144B185   742	5533014001	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Issued	08/22/2019 12:00:00 AM	ADDRESS	34.09059	-118.33004	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30079	18041-10000-22471	9843-9853 N MASON AVE Bldg 5	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.24903	-118.58076	SEE APPLICATION NOTEFULL PC FOR A CORE AND SHELL FOR NEW 1-STORY BUILDING WITH RETAIL AND RESTAURANT SPACES.. SCOPE OF WORK INCLUDES NEW 3000A SERVICE, WITH TENANT PANELS AND COMMON AREA CIRUITS. BUILDING 5 TOTAL SQ. FT. FOR OUTDOOR 5878 INDOOR 10435.B#18010-10000-01050	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30080	12041-20000-14823	4963 N BALBOA BLVD	91316	5	171B133   722	2258019010	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.16118	-118.50128	new service 600 A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30081	12041-10000-25690	10250 W SANTA MONICA BLVD 410	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	PLAN CHECK FOR T24. TI TO RETAIL FOR NEW (NOT FIRST TIME) TENANT. RELOCATE PANEL. 1034 SF. WESTWOOD MALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30082	19041-20000-37078	614 S MATEO ST	90021	14	126A217   204	5164013015	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.03738	-118.23248	Plan check for Title 24 energy only in existing space Tenant Improvement to retail. Total area: 3094 sq ft. B#19016-10000-16982	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30083	18041-20000-47481	1155 W 36TH PL	90007	8	120B197   989	5040029017	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			12/14/2018 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.02221	-118.29327	Plan check for power and energy for multi-family building  5 units 3 story. Total area: 6270 sq ft.B#17010-10000-04522	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30084	14041-20000-02787	4403 S LINDBLADE DR	90066	11	108B157   222	4232020002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Expired	02/25/2016 12:00:00 AM	ADDRESS	33.99508	-118.42117	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.4KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30085	12041-10000-29100	777 S FIGUEROA ST # 2500	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.04828	-118.26116	Tenant improvement in existing offices. Plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30086	15041-20001-01340	21040 W CALIFA ST SUITE A	91367	3	174B105     8	2149002021	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	ADDRESS	34.17715	-118.59163	"10/20/2015 Changes to an approved set of plans. Plan check for Delta 5 changes only. Changes includes the addition of a lockable, fused disconnect switch to the secondary of transformer ""T-2"", and the removal of the main of panel ""DL"". Other Deltas (2 and 4) are not included in this plan check.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE OF FROM OFFICE TO DIALYSIS CLINIC. PC FOR MEDICAL PER ARTICLE 517. NO CRITICAL CARE AREAS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30087	14041-10000-06663	12050 W VENTURA BLVD #201	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.14349	-118.39426	Ti in a restaurant. No new panel. EPC is for T24 and emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30088	13041-20000-24040	1068 W VIA CORDOVA	90732	15	021B193    83	7445019084	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	33.75466	-118.3014	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING 25 MODULES. 3 STRINGS. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30089	18041-10001-03604	1705 S 3RD AVE	90019	10	126B189   635	5072029009	RD2-1-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.20	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.04159	-118.32026	PV1 for a new solar system on existing residential roof-top. Total system size is 4.2KWdc / 3.45KWac.(15)MODULES-RECOM RCM-280-6MB(15)MICROINVERTERS-ENPHASE IG6-60-2-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30090	17041-10000-27275	1318 E 7TH ST STE #150	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.03608	-118.24052	PC for T24. Installing new lights, panels, receptacles and HVAC equipment. Total affected area is 500 sqft. Building# 17016-10000-13807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30091	13041-10000-33631	17417 W PARTHENIA ST	91325	12	195B129   420	2768015035	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	12/24/2013 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.22873	-118.51399	PV1.  Install 6.00 kW DC roof-mounted PV system, interconnect with main service panel.  20 modules: PHONO SOLAR 300W.  Transformerless inverter: SMA 5000-TL [[[[[NOTE FOR PLAN CHECKER TO BE REMOVED, PLEASE VERIFY INFO12/9 - APPLICANT NOTED ITS OWNER BUILDER, WHICH IS NOT ACCEPTED -KUMAR ]]]]]]conduit running above ground per applicant (inspector to verify corrosion and trip hazard is not an issue). Change to THWN-2 instead of THHN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30092	18041-10000-09079	617 W 7TH ST	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.04779	-118.2571	PC for T24 only for new lighting in kitchen for an existing comissary. Installing new lights, receptacles, equipment and new panel. Total area 849sqft. Total area 17016-10000-27606.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30093	19041-10000-46804	1968 W ADAMS BLVD	90018	8	123B193   640	5053011036	C2-2D-O-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.03251	-118.30813	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30094	10041-20001-02966	440 S VERMONT AVE Market	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Delta 3 revision to approved plans. Changes to lighting and additional ckts added to panels in the market area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30095	16041-20001-02288	6225 W CENTURY BLVD 1st Floor	90045	11	090B165     5	4124026005	C2-2, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM			PC Info Complete	11/17/2016 12:00:00 AM	ADDRESS	33.9457	-118.39456	11/17/2016 Changes to an approved set of plans. All changes have been clouded. Revisions have been made to the lighting and power floor plans. *****Previous Work Description*****TI to existing high rise commercial building (hotel). Plan check for energy only. Adding new lighting including emergency lights. Total sqft. 40,872Note: Building applications have created under 15016-10000-09745 and 15016-10000-09747	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30096	12041-10000-25417	645 N EUBANK AVE	90744	15	030B209   367	7424008026	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	33.77816	-118.25463	INDUSTRIAL LOCATION. INSTALL NEW 400 AMP LOAD CENTER 480V (3) AND ELECTRICAL FEED TO NEW BOILERS AND FEEDWATER SUPPORT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30097	14041-10000-00742	5857 S CENTRAL AVE STE # 110	90001	9	108B209  1588	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	Plan check for power and energy for First time tenant, just take out little ceasar fast food. Total area 1190 sq ft.****Permit number for core and shell related to  this building is 12041-10000-30230.****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30098	14041-20001-12032	12642 W SANDHILL LANE Unit #3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.97765	-118.41437	Fee for expedite only.*****Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 3 of 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30099	18041-20000-42390	2429 1/2 E CESAR E CHAVEZ AVE	90033	14	129A225   296	5177034019	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.04649	-118.20672	Plan check for PV roof mounted system, system size: 6.93kW DC  with 21 PV Modules and 1 inverter(6.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30100	11041-20000-15271	355 S GRAND AVE 15TH FLR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/21/2011 12:00:00 AM	ADDRESS	34.05191	-118.2525	Plan check T24 Energy general/emergency lighting for office TI on the 15th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30101	12041-20000-17253	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Closed	02/11/2014 12:00:00 AM	ADDRESS	34.17126	-118.58861	Install new UPS and HVAC equipment for medical building (Kaiser Permanente).  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30102	19041-10000-50708	700 S FLOWER ST 31ST FLOOR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.04835	-118.25882	T.I. PLAN CHECK FOR T-24 ENERGY ONLY. TOTAL AFFECTED AREA 22596sqft. SCOPE OF WORK INCLUEDES INSTALLATION OF NEW PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30103	13041-20000-26786	11800 W PICO BLVD	90064	11	123B149   887	4259039001	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	09/26/2013 12:00:00 AM	ADDRESS	34.03034	-118.44738	T24 FOR RETAIL SPACE. NEW CONNECTED LOAD DOES NOT EXCEED 400A. TOTAL SQRFT 1062	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30104	19041-20000-20079	8420 N LANKERSHIM BLVD	91352	6	192B169   383	2632022002	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Closed	10/20/2022 12:00:00 AM	ADDRESS	34.22367	-118.38757	service upgrade 800 amps to an existing commercial building.  reconnecting existing panel A.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30105	17041-20001-43118	257 S MARIPOSA AVE	90004	10	135B197   154	5518007026	C2-1, R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.06962	-118.29936	06/19/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. (2) subpanels and (58) new circuits have been added, as indicated on the SLD. There have been lighting changes throughout the common area lighting floor plans and have been reflected onto the Title 24 Compliance forms. The fire pump has been removed from the SLD. Fire pump section and switchboard have been removed. Emergency egress lighting has changed from inverter to unit equipment. Changes have been made to the apartment units: architectual, lighting, and power changes.*****Previous Work Description*****Plan check for power and energy. New 7 story, mixed use building with 6 residential levels (121 units) over retail and retail parking at ground floor level . 2 levels of sub-terranean residential parking. 3,000A 208/120V 3ph 4w service. 3 typical units. Title 24 area: indoor-76,937sqft; outdoor-19,434sqft. Project is located in methane buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30106	17041-10001-04817	5307 N SEPULVEDA BLVD	91411	4	172-5A145  58	2250001002	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			02/14/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.16692	-118.46643	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 144kW with 4 inverters(36kW) Yaskawa PVI 36TL and 468 Modules SUNPOWER X21-345-COM connected to 1000A switch borad}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30107	16041-10000-06344	235 S HOPE ST	90012	14	132A211    47	5151014034	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Issued	03/09/2016 12:00:00 AM	ADDRESS	34.05452	-118.25185	PC FOR POWER ONLY FOR TWO TEMPORARY POWER SERVICES AND DISTRIBUTION EQUIPMENT FOR A CONSTRUCTION SITE. SCOPE INCLUDES TWO SERVICES, AND TWO MAIN SWITCHBOARDS. TWO SERVICES ARE APPROVED BY DWP.  LOADS ON MAIN PANELS DX-01 AND DX-02 ARE FOR FUTURE AND REFERENCE ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30108	14041-20000-06116	10115 W RIVERSIDE DR	91602	4	165B181    35	2424008013	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.15237	-118.35118	plan check for T24 energy only. juice bar. load less than 400A. permit already issued	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30109	17041-10000-37855	1132 N GLENDALE BLVD	90026	13	139-5A207 131	5404016022	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	03/18/2022 12:00:00 AM	ADDRESS	34.07702	-118.26071	PARKING MOUNTED PV SYSTEM, SYSTEM SIZE IS 400KWac CONSISTING OF 8 CENTRAL INVERTERS SUNNY TRIPOWER CORE1/US AND 1447 MODULES SUNPOWER X22360. B#17016-10000-37519	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30110	18041-30000-39080	17400 W VICTORY BLVD	91406	6	177B129     8	2229033900	A2-1-RIO, OS-1XL-RIO	South Valley	Reseda - West Van Nuys	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	03/20/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.18631	-118.51407	Plan check for PV roof mounted system Feed in Tariff(FIT), system size: 427.74 KW AC CEC, 471.63 KW STC, 333.33 KW AC with 1194 PV Modules, Optimizers and 10 inverters(33.3KW) connected to 600A distribution(FIT). $0 due for inspection due to senate bill 1222.B#18010-30000-04940,18010-30000-04941,18010-30000-04942	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30111	13041-10000-15224	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK FOR POWER AND ENERGY, FIRST TIME TENANT AT LAX TOM BRADLEY INTERNATIONAL TERMINAL. SPACE T29 AND HMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30112	17041-10001-26199	232 E 2ND ST Unit B	90012	14	129A213    28	5161024034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.0495	-118.24258	PC FOR POWER AND ENERGY FOR A FIRST TIME TENANT RESTAURANT IN A HIGH RISE BUILDING. ENERGY FEES COLLECTED UNDER MASTER APPLICATION. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTING. MASTER APPLICATION MADE ASSUMING (E) SPACE HOWEVER, THIS IS FIRST TIME TENANT. Total affected area of 1980 sqft. Building #17016-10000-10743	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30113	10041-10000-09528	1200 W 7TH ST 1th Floor	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.05136	-118.26616	TI IN AN EXISTING COMMERCIAL SPACE ON THE 1st FLOOR. PLAN CHECK IS FOR ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30114	15041-10001-09643	19600 W PLUMMER ST # 700	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.2426	-118.5602	Supplemental PC only. Em. light (CE) being fed from the inverter with its circuit independent from the normal lighting ckt.. ((T.I FOR NEW RESTAURANT, PC FOR ENERGY AND POWER.  PROOSED OCCUPANT LOAD EXCEEDS 100 OCCUPANTS PER APPLICANTS.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30115	18041-20000-37685	7945 N BALBOA BLVD	91406	6	189B133   476	2204024014	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.21512	-118.50149	permit fees $0.00 by state senate bill no. 1222Plan check for PV roof mounted system, system size: 23.76KW DC, 22.19KW AC with 72 PV Modules and 2 inverters(10.0KW) connected to 400A panel supply side connection	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30116	13041-10001-27895	1857 N PHILLIPS WAY	90042	14	157-5A227 146	5479018017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.12644	-118.20082	][][]EXPEDITED PER APPLICANT REQUEST ][][]PV1, 8.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(2) inverters: {SOLAREDGE SE5000A-US, SE3000A-US}]. [(34)modules: {HANWHA {#HSL60P6-PB-4-250TW}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-AH4SM-2NA-Z}. (E) 125A MAIN. THE 250W OPTIMIZERS WILL BE CHARGED UNDER NON-DWELLING POWER EQUIPMENT. LOAD CENTER WILL BE USED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30117	19041-20000-40222	14604 W ISLA VISTA DR	91402	6	201B149   892	2650019065	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.2474	-118.45054	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 3.15 KW DC/2.835 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH INTEGRATED MICRO INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30118	19041-10000-06996	7525 N TOPANGA CANYON BLVD	91303	3	186B101   309	2023002001	[Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.20725	-118.60619	PC T-24 ONLY, CHANGE OF USE FROM DENTAL OFFICE/PHARMACY TO OFFICE. SCOPE AREA 3260SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30119	14041-20001-01096	7654 N BALASIANO AVE	91304	12	186B093   717	2014033044	(Q)RD5-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.20932	-118.63121	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER USING POWER OPTIMIZERS.(((EXPEDITE FEES)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30120	14041-20000-17379	12154 W MONTAGUE ST	91331	7	204B165    89	2537018027	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.25712	-118.39806	Plan check for power and energy. Tenant improvement in warehouse/manufacturing building. Building equipment, lighting, and wiring is all new, including a new 4000A service. 127,200 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30121	10041-10000-22852	225 S 26TH ST 7	90049	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	12/04/2010 12:00:00 AM	PIN	34.04786183	-118.49061927	TI IN A RETAIL STORE. EPC IS FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30122	11041-10002-11319	6022 W AVION DR	90045	11	090B165    36	4129028900	M2-1	West Los Angeles				9800.28	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	33.94182	-118.39269	Additional branch circuits amd update configuation. Modification to Delta 5 to previously approved set of plans.  Plans were submitted and approved under 11041-10000-11319.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30123	10041-10000-22559	4501 W COLORADO BLVD BLDG  8	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.14246	-118.2705	NEW 2-STORY MANUFACTURING FACILITY WITH PARTIAL BASEMENT AND TWO EQUIPMENT PLATFORMS.  (Parallel Design-Permitting Program 30% submittal complete zoning, partial disabled access, partial life safety)  REF.#10042-10000-19492.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30124	12041-10000-29326	1067 N SANBORN AVE	90029	13	145-5A201 385	5427006005	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	ADDRESS	34.09197	-118.28086	PV1 SINGLE STORY ROOF MOUNTED SOLAR INSTALLATION. INTERCONNECTED WITH MAIN SERVICE PANEL. SYSTEM SIZE IS 3.36 KW. ONE SINGLE STRING WITH 14 MODULES AND USING TRANSFORMERLESS INVERTERS [INVERTER: SOLAREDGE # SE3000A-US ||||| PV MODULES: TRINA SOLAR # TSM-240PA05]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30125	15041-10005-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	11/03/2016 CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REVISED CIRCUITS TO INCLUDED ROOMS ON PANEL SCHEDULE, ADDITION OF NEW BRANCH CIRCUITS, REMOVAL OF LIGHT FIXTURE AND RELACATION AND REMOVAL OF RECEPTACLES ON FLOOR PLAN. CHANGES HAVE BEEN CLOUDED AS (DELTA 37) ON PLAN.NOTE : PACKAGE #6.INCLUDED ARE DELTA # 35 CHANGES(APPROVED SET).DELTA # 36 CHANGES ARE STILL IN PLAN CHECK UNDER APPLICATION 15041-10004-14585	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30126	15041-10000-23797	4700 W PICO BLVD # S	90019	10	129B185  1011	5083033015	[Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.04846	-118.33732	Full plan check for a medical office ( Chiropractic) TI; Scope includes new lighting, equipment and receptacles. Total area is 1831-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30127	15041-10000-35281	10635 W SANTA MONICA BLVD Suite 145-150	90024	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Info Complete	10/21/2015 12:00:00 AM	PIN	34.05365874	-118.43036269	Energy plan check for an office T.I ; Scope includes new lighting and receptacles. Total area is 141-sq feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30128	11041-10000-24510	1664 W 222ND ST	90501	15	048B193   604	7346019001	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2011 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	33.82552	-118.30864	New rooftop photovoltaic system for a single family residence using Enphase M215 micro-inverters.  Variance will be filed to use unapproved Enphase equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30129	17041-10000-20460	8365 W SUNSET VIEW DR	90069	4	147B173     2	5556034004	RE9-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.09938	-118.37232	New two story single family dwelling with attached garage over basement with roof deck.Permit pulled under Building application number. B#15010-30000-04172	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30130	14041-10000-35421	5514 N BONNER AVE 1-32	91601	2	174B173  1216	2350005045	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			12/22/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.17048	-118.37401	Plan check for power and title 24.  Total area = 21,497 sq. ft. indoor and 6,199 sq. ft. outdoorNew 4 story 32 unit apartment building with 10 typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30131	16041-30000-44161	4364 S MCLAUGHLIN AVE	90066	11	111B161   643	4217009018	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			12/15/2016 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	33.9991	-118.41557	Plan check for power and energy. Project site is a new 7-unit, 4-story aparment building. Work includes a new 800-amp service, distribution equipment and loads.Fire varience was filed.Note: Building application has been generated under 15010-30000-03174	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30132	19041-10000-41497	10430 N MONTGOMERY AVE	91344	12	207B141   853	2668018016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.26019	-118.48146	Permit fee is $0.00 due to Assembly Bill 1414.PLAN CHECK FOR ROOF MOUNTED 12KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE6000H-US) and 48 MODULES USING P320 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30133	11041-10000-27590	738 S ALAMEDA ST Room 15,-16, 17	90021	14	123A215   227	5166032037	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.03271	-118.23638	T.I. to existing building.  Install genral lighting in room 15, 16, 17.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30134	12041-10000-00506	441 W 3RD ST 1-92	90731	15	018B201   816	7455002027	R4-2	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Public Safety Only			01/09/2012 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	ADDRESS	33.74132	-118.28683	REPLACING FA PANEL WITH AN ADDRESSABLE TYPE  OF THE SAME MANUFACTURER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30135	17041-10000-42096	11210 W SARDIS AVE PV-1	90064	5	123B157  1225	4251002023	R3-1	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	Apartment			11/20/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.02959	-118.43029	PC for PV rooftop for new 22.8kW systen on apartment building. Installing 70 new modules with optimizers, 100 A load center and three central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30136	11041-10000-02951	6351 W WILSHIRE BLVD	90048	5	135B173   825	5510028008	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM			PC Approved	02/18/2011 12:00:00 AM	ADDRESS	34.06381	-118.36703	TI IN AN EXISTING OFFICE BLDG. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30137	18041-10000-12773	2251 W VENICE BLVD	90006	10	126B193   263	5074013013	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.04372	-118.30789	PC for rooftop solar for 7.28kW(ac)/9.1kW(dc) for commercial building. Installing 26 PV modules with microinverters.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30138	10041-10001-23100	6561 W HOMEWOOD AVE	90028	4	147A187   329	5547027018	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.09534	-118.33248	PLAN CHECK 4.6KW ROOF MOUNTED ENPHASE M215 PHOTOVOLTAIC SYSTEM FOR COMMERCIAL CARE HOME. SUPPLEMENTAL APPLICATION/PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30139	10041-10000-25437	10636 W WILSHIRE BLVD	90024	5	132B153   154	4326001218	[Q]R5-3-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Info Complete	12/22/2010 12:00:00 AM	ADDRESS	34.06063	-118.4346	T.I. to existing building.  Install general lighting in Gym room.  Plan check for energy only.Note: Permit is under 10041-30000-20421.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30140	16041-10000-22896	1999 S BUNDY DR	90025	11	123B149   406	4259019007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM			PC Info Complete	07/11/2016 12:00:00 AM	ADDRESS	34.03406	-118.45593	NEW FIRE ALARM SYSTEM TO A COMMERCIAL BUILDING. 193 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL AND 1 BATTERY SUPPLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30141	18041-10000-16284	11435 W BIONA DR	90066	11	114B157   377	4234008039	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.01082	-118.42311	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM(3.8KVA) CONSISTING OF 1 CENTRAL INVERTER SE3800H-US WITH 15 PANELS USING P320 POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30142	17041-20000-19181	15260 W VENTURA BLVD Suite 700	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,400 sq. ft.Note: Building application has been generated under 17016-10000-09373	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30143	11041-20000-21779	11766 W WILSHIRE BLVD Ste 1160	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM			PC Approved	10/12/2011 12:00:00 AM	ADDRESS	34.04804	-118.46227	T.I.  Remodel of light fixtures in Suite # 1160.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30144	11041-20000-11099	11766 W WILSHIRE BLVD #1470	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM			PC Approved	05/31/2011 12:00:00 AM	ADDRESS	34.04804	-118.46227	energy plan check suite # 1470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30145	14041-20000-24013	10100 W SANTA MONICA BLVD 25th flr-suite 2500	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Info Complete	09/03/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	ti to an existing commercial building.  work to be performed on the 25th floor.  Addition of lights in office spaces and new circuits to power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30146	19041-10000-48024	12950 N BRADLEY AVE	91342	7	222B149   430	2506011002	M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.30531	-118.45936	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T-/24 ONLYOUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30147	12041-20000-05709	13955 N BALBOA BLVD	91342	7	228B137   226	2603025028	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.323	-118.49033	work shop energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30148	16041-10000-15069	3550 S OVERLAND AVE	90034	5	120B161   895	4314011050	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			04/29/2016 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	10/11/2023 12:00:00 AM	ADDRESS	34.02383	-118.41069	New 5-story 60-unit affordable housing apartment over 2-levels of subterranean parking. 1600A service. 24 Typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30149	18041-20000-38452	1000 S HOPE ST pv2	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.04346	-118.2617	Plan check for a PV2 roof-mounted PV system. System size is 46.08 kWdc/40 kWac and consists of (2) inverters, (128) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30150	17041-20001-11821	4501 N CEZANNE AVE	91364	3	165A105    16	2173002011	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM			PC Approved	04/17/2017 12:00:00 AM	ADDRESS	34.14819	-118.60381	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp. center fed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30151	11041-10000-06301	125 E PASEO DE LA PLAZA	90012	14	132A215    62	5408011908	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Expired	01/23/2015 12:00:00 AM	ADDRESS	34.05631	-118.23891	NEW FIRE ALARM PANEL, WITH REPLACEMENT, ONE-FOR-ONE, OF 17 DEVICES WITH NEW DEVICES.  EL PUEBLO AREA.  5 STORY BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30152	17041-20000-38957	3627 N CODY ROAD	91403	4	159B145    65	2278024004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.1361	-118.46394	Installation of 27 kWh energy storage system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30153	17041-10002-41690	5028 N CARTWRIGHT AVE	91601	2	171B177  1128	2419014007	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.16207	-118.36357	Supplemental for 5kW battery backup and new 100A panel and new autotransformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30154	17041-10000-08953	5800 W SUNSET BLVD 1ST FLR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM			PC Info Complete	05/19/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	FULL PC FOR POWER AND ENERGY. CHANGE OF USE OF A PORTION AT 1ST FLOOR FROM OFFICE TO RESTAURANT. SCOPE INCLUDES ONE NEW 5KV FEEDER, NEW 400A DISTRIBUTION BOARDS, NEW TRANSFORMERS, NEW PANELS, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 3368 SQ. FT. B#17016-10000-04839	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30155	18041-10000-18849	317 W PACIFIC COAST HWY	90744	15	036B205   998	7421024014	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM			PC Info Complete	05/21/2018 12:00:00 AM	ADDRESS	33.79117	-118.26668	Plan check for energy only, lighting alteration (T24) for Commercial retail TI, Chase Bank. New lights will reuse existig circuits and lighting controls in the area.Total area: 6,311 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30156	17041-10000-07821	10251 N FLORALITA AVE	91040	7	204B189   711	2560020028	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.25576	-118.31854	Plan check for PV roof mounted system. System size: 11.6kWdc with 44 module and 1 inverter(10kW), in a 1 or 2 family dwelling	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30157	13041-20001-23760	4652 N WILLENS AVE	91364	3	168B097   540	2074042010	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.15539	-118.62691	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.6 KW USING 23 MODULES. NONSTANDARD PLAN TRANSFORMERLESS INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30158	18041-10001-09476	1360 S FIGUEROA ST SPACE #1	90015	14	126A205    86	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.03896	-118.26891	SUPPL PC FOR LOST PLANS. <<<<PC FOR ENERGY ONLY FOR T-24 CHANGE OF USE FROM RETAIL TO NAIL SALON TENANT IMPROVEMENT. SCOPE INCLUDES NEW CIRCUITS LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 2126 SQ.FT FOR LOW RISE BUILDING>>>>B#18016-10000-06993	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30159	13041-10001-19393	6801 W HOLLYWOOD BLVD A2-203-A3-303,305	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.10229	-118.33907	][][applicant changed site address & requested new sets to be stamped that reflected the new address; no other changes were done other than the corrected change of address. additional hour charged for the stamps.][][ Tenant improvement to units in shopping complex on corner of Hollywood and Highland belonging to Starline Tours.  New 75 kVA transformer and 3 new panels.  Modify outlets and lights per new layout.  Newly connected load < 400 A, title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30160	13041-20000-19769	4550 W PICO BLVD C322	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	((changes to approved set of plans. new enginner on record. application taken as new. t24 energy only. )))Retail TI for new clothing store in shopping center.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30161	16041-10003-29518	1825 N LAS PALMAS AVE 1-118	90028	13	150A185   301	5547001022	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			09/10/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.10476	-118.33652	"DELTA ""7"" CHANGES TO APPROVED PLANS - CHANGES INCLUDE ADDITION OF A NEW EMERGENCY TRANSFER SWITCH AND RELOCATION OF EMERGENCY LOADS, TITLE 24 REVISIONS (REG & EMERGENCY) LIGHTS AND OTHER REVISIONS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30162	13041-10000-12701	333 S HOPE ST 16TH FL	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	13041-10000-12701REMODELING EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30163	12041-10000-27902	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	NO: 11111 - electricalDO NOT ISSUE ANY PERMIT (BUILDING, MECHANICAL, OR ELECTRICAL) TO ADD, ALTER, DEMOLISH, OR CHANGE OF USE WITHOUT AN APPROVAL FROM CRA. THIS IS A HISTORICAL SIGNIFICANT BUILDING. THE EXCEPTION NOT REQUIRING SIGN OFF FROM CRA FOR TI ABOVE THE 2ND STORY DOES NOT APPLY TO THIS BUILDING/STRUCTURE.�Note: if the permit is subject to CRA clearance and this building is also a City monument, instruct customer to obtain clearance from City Planning Office of Historic Resources prior to obtaining a CRA approval.(created: KGILL / 11-23-11)---------------------------gnerator?TI FOR EXISTING LOBBY. HIRISE. 1ST/2ND FLOOR. 19380 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30164	18041-10000-19821	606 W EL SEGUNDO BLVD	90061	15	081B201   278	6132003029	[Q]CM-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	33.9162	-118.28488	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30165	15041-10000-33915	801 S FIGUEROA ST STE 400-425	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.04789	-118.26153	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 4473 SCOPE OF WORK IN SUITE 400 AND 425.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30166	16041-30000-43759	801 S FIGUEROA ST 1st Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the 1st floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,560 sq. ft.Note: Building application has been generated under 16016-30000-29871	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30167	19041-20000-15320	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.17126	-118.58861	T24 ONLY PLAN CHECK FOR EXISTING COMMERCIAL BUILDING. CHANGING OF OUTDOOR FLOURESCENT LIGHTS TO LED LIGHTS TOTAL SQUARE FOOTAGE = 10,500SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30168	18041-10000-38754	648 E 21ST ST	90011	9	121-5A209 283	5127005006	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.02595	-118.259	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30169	13041-10001-33012	2402 N EDGEWATER TER	90039	4	148-5A209 307	5439014017	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.10091	-118.26022	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 4.5KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(18) TRINA SOLAR # TSM-250(18) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE5000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30170	14041-10000-06608	3650 W MARTIN LUTHER KING, JR BLVD # 112	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	Interior tenant improvement and expansion of retail space w/in existing lease area, including:.  No change of use.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30171	16041-20000-12910	1225 W JAMES M. WOOD BLVD	90017	1	129A205    78	5143002019	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.04886	-118.26841	Plan check for energy only. Change of use from retail to adult day care on first floor. New interior lighting (incl. emergency). 8,400sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30172	17041-10000-10802	1639 N VINE ST	90028	13	148-5A187 206	5546009038	C4-2D, C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.10094	-118.32687	PC for energy only, change of use retail to massage. New Lighting and power. Area: 5499	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30173	16041-10000-24383	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.08901	-118.34188	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW SIX STORY TYPE I-B MEDIA PRODUCTION BUILDING. SCOPE INCLUDES 135 FA DEVICES, 1 FIRE ALARM PANEL, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30174	16041-20000-44118	7843 N MELITA AVE	91605	12	189B157   678	2303011043	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.21291	-118.42022	PV1.  Install 7.6 kW roof mounted grid tied PV system with battery backup.  (25) modules with (1) 7.6 kW rated central inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30175	17041-10000-00400	7353 N HILLSVIEW CT	91307	12	186B089   413	2027047015	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.20547	-118.65133	PV, INSTALLATION OF 11 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(32) AC MODULES: SUNPOWER SPR-X21-345-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30176	19041-10000-41229	860 S NORMANDIE AVE	90005	10	132B197   782	5094018001	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			10/10/2019 12:00:00 AM			PC Info Complete	12/24/2020 12:00:00 AM	ADDRESS	34.05607	-118.29966	New 6 Story (Low Rise), 57 Unit apartment w/ Roof Deck and 2 level of basement parking with a 1,200 Amp Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30177	12041-10000-03851	10118 N CREBS AVE	91324	12	204B121   408	2729007001	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2012 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	ADDRESS	34.2537	-118.54381	New roof mounted 9.4 KW solar system for a single family. (Service panel upgraded to 225 Amp)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30178	18041-20000-43348	6803 N YARMOUTH AVE	91335	3	183B129  1084	2122014001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	PIN	34.19415056	-118.51988171	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30179	17041-20003-45582	16633 W OAK VIEW DR	91436	5	168B137   395	2289020013	R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.15694	-118.49746	Revisions to approved set. Relocation of equipment.  $0 plan check fee per State Senate Bill SB 1222.(((02/28/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the configuration of system interconnection.*****Previous Work Description*****Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(36) 300W pv modules. (2) 5kW Tesla Powerwall 2s.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30180	14041-20001-29874	12860 W RIVERSIDE DR	91604	4	168B161   422	2357033021	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	PIN	34.15733931	-118.41348969	"07/14/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 2. Changes include the relocation of Distribution Panel ""DP"".*****Previous Work Description*****Plan check for power only. Adding new car wash to existing gas station -> Upgrading service to 800A, installing new distribution equipment, and reconnecting existing equipment. Applicant had a precalculated check, verify/change/adjust fees on final."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30181	12041-10000-01205	8500 W BEVERLY BLVD #607	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM			PC Approved	01/18/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) RETAIL SPACE;   (N) LIGHTING FIXTURES; FITTING ROOMS TO REMAIN; NO CHANGE IN USE; 4,148 SQ. FT.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30182	17041-20000-08095	423 W 16TH ST	90731	15	012B201   412	7456023010	R2-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	04/20/2018 12:00:00 AM		Issued	04/20/2018 12:00:00 AM	ADDRESS	33.72956	-118.28628	"service upgrade 800 amps.  plan check for power only. methane zone. panels ""A"" and ""B"" new with no loads."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30183	16041-20000-16357	13137 W BRYSON ST	91331	6	195B161   570	2627035018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.23003	-118.41855	PV1INSTALL ROOF MOUNTED PV SYSTEM STANDARD PLAN.  SYSTEM SIZE 5KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30184	19041-10000-33058	660 S FIGUEROA ST 1600	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR T24 ONLY, SCOPE OF WORK IS A TI 16TH FLOOR OF A  EXISITING HIGHRISE (SUITE 1600). SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 4014 SQFT. B#19016-10000-26145NON-STRUCTURAL T.I.; INTERIOR PARTITON DEMO. NEW PARTITIONS. LIGHTING. 3,434 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30185	11041-20001-18010	10960 W WILSHIRE BLVD 1550	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	T.I.  Remodel of light fixtures in suite 1550.  Plan check is for energy only.   <<<<<<<Tenant Improvement- Install motion sensors and switches, install duplex outlets and 4-plex outlets, install power for (2) partition feeds, relocate power for (1) card reader.>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30186	19041-20000-51498	861 N ALMA REAL DR	90272	11	126B125   140	4411002901	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM			PC Info Complete	12/13/2019 12:00:00 AM	ADDRESS	34.04437	-118.52499	T24 ENERGY ONLY PLAN CHECK, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 1078 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30187	16041-20001-43611	10250 W CONSTELLATION BLVD 8th & 9th-Floors	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	6/7/17changes to an approved set of plans.  changes noted delta 5.  changes include lighting fixtures and quanties.  revised energy calculations.(((((Plan check for power and energy. TI to office on 8th and 9th floors of high rise building. New lighting (incl. emergency) and receptacles. ~>400A of new load. 29,301sqft.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30188	13041-20000-16541	17123 W ADLON ROAD PV-1	91436	5	165B133   478	2292011006	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.14554	-118.50642	PV-1. two 3.6kW Transformerless and one 7kW transformer equipped inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30189	10041-10000-19768	1261 N ANGELO DR	90077	5	144B153   454	4357012002	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	34.09187	-118.43619	INSTALLATION OF 68KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30190	13041-10000-23187	1028 S SEASIDE AVE Berth 259	90731	15	015B205    18	7440032904		Harbor	PORT OF LOS ANGELES			2961.00	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	33.73466	-118.26899	Plan check for new service and power for above ground (3) 12,000 gallon tanks (diesel) for refueling boats. Berth 259	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30191	19041-10000-51868	1237 S ALVARADO ST	90006	1	129A201   163	5136024008	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	08/01/2020 12:00:00 AM	ADDRESS	34.04783	-118.28252	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30192	15041-20000-29259	10201 W PICO BLVD Galaxy-parking	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Issued	03/02/2016 12:00:00 AM	PIN	34.05182951	-118.41257696	PV2 Installation of (1) commercial carport canopy solar PV Power system,(2128) modules: sunpower SPR-E20-327-COM(19 inverters: CPS SCA 28KTL-DO/US1 out of 3 sites on the same address.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30193	17041-10000-24980	720 W 108TH ST	90044	8	088-5A199  43	6061008011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	33.93808	-118.28784	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 3.9KWACSCOPE INCLUDES 12 AC MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30194	19041-10000-07809	16730 W CHATSWORTH ST	91344	12	207B137   440	2684002901	OS-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.26459	-118.49686	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30195	18041-20000-35315	10639 N IRMA AVE	91042	7	207A195   176	2557024022	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.26255	-118.30087	Plan check for a PV1 roof-mounted PV system. System size is 7.06 kWdc/7.6 kWac and consists of (1) inverter, (24) modules, (1) transformer, (1) load center, and (1) back-up battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30196	18041-20002-23643	7215 W WARING AVE	90046	5	141B181   259	5525002038	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM			PC Approved	09/06/2018 12:00:00 AM	ADDRESS	34.08537	-118.34667	Revisions to approved set of plans.  Change of module type from JA Solar 360W to S-Energy 355W.  (((Plan check for a PV2 roof-mounted PV system. System size is 34.56 kWdc/31.47 kWac-CEC and consists of (2) 14.4 kWac rated inverters, (96) modules, and (1) load center.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30197	11041-10000-16465	8384 W 3RD ST	90048	5	138B173   836	5511031049	C2-1LD-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.07283	-118.37279	T.I.  Existing restaurant on the bottom floor of a 5 story building. Redmodeling of the lighting.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30198	16041-10000-08379	7744 N LANKERSHIM BLVD	91605	6	189B169   744	2316001800	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21165	-118.38761	NEW 200KW FUEL CELL SYSTEM TO SUPPLY A COMMERCIAL BUILDING(TELE-COMMUNICATION). NEW 400AMP FEEDER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30199	11041-10000-19004	10250 W SANTA MONICA BLVD # 680	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IMPROVEMENT IN A RETAIL STORE AT THE CENTURY CITY MALLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30200	14041-20000-28253	13215 W RIVIERA RANCH ROAD	90049	11	132B137   110	4425024003	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM			PC Info Complete	10/30/2014 12:00:00 AM	ADDRESS	34.06069	-118.49726	"Plan check for power only. Brand new 2-story single family dwelling, 12,000sqft.Panel ""1A"" branch circuits not included in submittal fee, add fees to final."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30201	17041-10000-22941	9010 N BALBOA BLVD	91325	12	195B133     9	2688025012	(Q)C2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Info Complete	07/26/2017 12:00:00 AM	ADDRESS	34.23417	-118.50235	PC FOR T24 ENERGY ONLY. LIGHTING UPGRADES FOR RETAIL STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30202	11041-20000-17657	11118 W MAGNOLIA BLVD	91601	4	171B173   621	2353005009	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.1647	-118.37313	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT TO NEW BUILDING 600A SERVICE. EXISTING SPACE /BUILDING. CORE AND SHELL ELECTRICAL PLAN CHECK UNDER #09041-10000-22565	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30203	19041-20000-33696	20341 W FULLBRIGHT PL	91311	12	207B113    64	2707004010	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.26563	-118.57627	Plan checkf or PV roof mounted system, PV System size: 10.88KW DC, 9.8KW AC with 32 PV Modules and 32 Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30204	18041-20000-26287	19161 S HARBORGATE WAY	90501	15	060B193   442	7351021044	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM			PC Approved	07/13/2018 12:00:00 AM	ADDRESS	33.85627	-118.30374	Plan check for Title 24 only for addition of Mezznine for office space use to existing manufacturing Building. Total area: 700 sq ft. B#8014-20000-02583	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30205	16041-10000-45674	307 N WILMINGTON BLVD BLDG 6	90744	15	027B205   659	7417010937	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	33.77243	-118.27378	PC for new fire alarm system with 42 devices and 2 panels for apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30206	10041-20000-02104	10960 W WILSHIRE BLVD 22 nd fl.	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM	03/24/2010 12:00:00 AM		Permit Expired	12/11/2015 12:00:00 AM	ADDRESS	34.058	-118.44597	22 nd  floor office t.i.Energy, emergencyRequest for Modification to separate Fire Alarm  systen filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30207	16041-10000-23722	1262 E PALMETTO ST BLDG 4	90013	14	126A217    44	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.04005	-118.23347	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW COMMERCIAL BUILDING/PARKING STRUCTURE (BLDG 4). SCOPE INCLUDES 146 FA DEVICES, 1 FA PANEL, AND 1 COMMUNICATION PANEL. SUBMIT PLANS PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30208	14041-20001-07630	6900 N WINNETKA AVE	91306	3	183B113   690	2135030006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.19574	-118.57078	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30209	16041-10000-32638	715 S GAYLEY AVE	90024	5	135B149   468	4363007901	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.06512	-118.44812	Removing HID fixtures and replacing with new 23 LED fixtures PC T-24 only .includes 10450 sqft of outdoor area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30210	17041-20000-15959	12765 W BLUFF CREEK DR	90094	11	102B161  1270	4211037208	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	33.97458	-118.41639	INSTALLATION OF A NEW FIRE ALARM SYSTEM FOR  NEW 4 STORY CONDO APARTMENT BUILDING . 1 FACP AND 79 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30211	15041-10000-05292	8155 N LANKERSHIM BLVD	91605	6	192B169   634	2310007024	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.21897	-118.38801	Energy plan check for a commercial warehouse building, replacing HID fixture with new LED fixture; total area is 10220 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30212	15041-10000-12243	300 WORLD WAY Terminal-3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	33.94502	-118.40714	Energy plan check for ticket counters area located in terminal 3 of LAX airport. scope include installing new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30213	11041-10000-23439	20600 W VENTURA BLVD North-1-123	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			11/03/2011 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	North Building of a New 123 unit Apartment building with Commercial space.  1200A service for Commercial space and 2000A service for apartment space.  Building Permit is 11010-10000-01958	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30214	11041-10000-25994	4445 N COLBATH AVE 1-33	91423	4	165B153   148	2271012038	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.15163	-118.4367	Maintenance upgrade/replacement of existing FACP and Annunciator for a fire alarm system with the addition of 12 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30215	18041-20000-06317	11759 W SAN VICENTE BLVD	90049	11	129B145    16	4401017007	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.05337	-118.46794	TI to first floor office and change of use on 2nd floor from residential to office.  New 200A service.  Plan check for energy.Building permit under 18016-10000-03529.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30216	14041-20000-30117	12346 W DORAN PL	91605	2	186B165   262	2307023***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	PIN	34.20823455	-118.40128125	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZED 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30217	15041-10001-24189	8731 S LINCOLN BLVD	90045	11	096B161   737	4119026038	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	33.95818	-118.41793	02/03/2016Changes to an approved set of plans, note changes on delta 5,6 and 7. Changes include the addition of circuits, panels and changes to T-24. ((Full plan check for interior remodeling; Scope include new lighting, eqpuipment and receptacle. Total (10) panels, (100) circuits, and 27,284-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30218	17041-10000-35032	3217 S CENTRAL AVE	90011	9	117A209   244	5114019013	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	34.0143	-118.25668	CHANGE OF USE TO RESTAURANT- BASKET ROOMFULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30219	17041-10000-07216	1218 S FAIRFAX AVE	90019	10	129B177   217	5086004015	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.05274	-118.36618	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 32525 SQ FT.  OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30220	16041-20001-04737	9537 N TEXHOMA AVE	91325	12	201B129   394	2755009026	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM			PC Approved	02/22/2016 12:00:00 AM	ADDRESS	34.24447	-118.51678	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (3) inverters, (50) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30221	16041-20000-20973	800 S FIGUEROA ST #950	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	Plan check Title 24 for existing high-rise. T.I. office space. Total area: 1,816 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30222	12041-20000-03417	1633 W RIVERSIDE DR	90031	13	144B213    88	5445001036	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	ADDRESS	34.09418	-118.24124	office t.i.Energy , emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30223	14041-10001-13241	1928 N MANDEVILLE CANYON ROAD	90049	11	135B137     5	4426010022	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			PC Approved	11/04/2014 12:00:00 AM	ADDRESS	34.06969	-118.49514	Plan check only. Plan check for power and energy. Changes to approved plans: change light from luminaire schedule and switching,  Added receptacles for more equipment, Heating loads removed; revised panel M1 for av equipment, water treatment, and microwave; revised panel M2 for revised lighting loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30224	19041-20000-15322	6320 N CANOGA AVE Ste 1300	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.18499	-118.59722	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30225	16041-20000-40742	15232 W FOOTHILL BLVD	91342	7	228B145   794	2502001171	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.32292	-118.46695	PV1.  Install 3.0 kW AC roof mounted grid-tied PV system.  (10) modules with (1) 3.0 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30226	11041-20000-20265	16521 W SATICOY ST South Bldg	91406	6	186B137    22	2205009009	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	10/04/2011 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.20858	-118.49305	Plan check power and energy for T.I.:  new office, conference room, bathrooms, & break room in (E) workshop (South Building) will supplying new North Building. Part 1 of 2. Original approved plans were lost #09041-20000-24396. Check under 2005 NEC & 2005 T24 ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30227	17041-20000-25591	8372 N TOPANGA CANYON BLVD SUITE 'B'	91304	3	192B101   469	2779043035	(Q)C1.5-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.22187	-118.60576	Plan check for energy only. Change of use from retail to massage parlor. New lighting - 1,380sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30228	12041-10000-06520	6333 W 3RD ST STALL#112	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM			PC Approved	04/06/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	NEW INDOOR  LIGHTING FOR EXISTING STARBUCKS. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30229	13041-10000-30041	380 WORLD WAY level05	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			Re-Activate Application	10/28/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR ENERGY ONLY. LEVEL 5 of tom bradley terminal. TI TO (E) STORAGE. 2 spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30230	17041-20000-23799	9137 N COLLETT AVE	91343	12	198B141   626	2671023005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.23692	-118.48412	pv1install roof mounted pv system sized 5.1kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30231	11041-10000-13261	33 N HALDEMAN ST	90402	11	126B129   842	4409029013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	PIN	34.03791832	-118.51332785	NEW SINGLE FAMILY RESIDENTIAL BUILDING WITH 600A SERVICE.  PLAN CHECK FOR POWER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30232	10041-10000-25396	1219 W 27TH ST	90007	9	123B197  1288	5055026031	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			12/22/2010 12:00:00 AM			PC Info Complete	04/12/2011 12:00:00 AM	ADDRESS	34.03041	-118.28714	Bath and Kitchen remodeling (USC).  Install subpanels, branch circuits, and lighting.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30233	17041-20000-24972	9841 N AIRPORT BLVD GROUND-FLOOR	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	PLANCHECK FOR T24 ENERGY ONLY.  UPGRADES TO GROUND FLOOR LOBBY. BUILDING PERMIT # 17016-10000-12771COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 02/03/17. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30234	12041-10000-24950	1648 W CARSON ST	90501	15	051B193   971	7346003043	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	33.83131	-118.30823	TI for a restaurant. EPC is for T24. (unit B)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30235	16041-10001-26853	9200 S FALMOUTH AVE	90293	11	093B157     3	4119006912	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM			PC Approved	09/23/2016 12:00:00 AM	ADDRESS	33.95226	-118.43281	09/23/2016 Changes to an approved set of plans. Changes include re-classify area from Class 1 Division 2 to Class 1 Dvision 1. Changes has been clouded Delta 1(((((FULL PC FOR POWER AND ENERGY. INSTALLATION OF PUMP BUILDING FOR STORM WATER PROJECT. METHANE ZONE. 400A SERVICE 600A SWITHCHGEAR.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30236	11041-10000-15686	633 W 5TH ST CONCOURSE	90071	9	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	12/30/2011 12:00:00 AM	ADDRESS	34.05099	-118.25468	REMODEL OFFICE SPACE AT THE CONCOURSE AND PARKING LEVELPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30237	19041-10001-24427	9736 N MARCUS LANE	91042	7	201A201   332	2564016051	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.24532	-118.28231	CHANGES TO APPROVED SET. UPDATING PLANS TO SHOW UPGRADED (225A) AND RELOCATED MAIN SERVICE PANEL. PANEL UPGRADE TO BE PERMITTED SEPARATELY(((PV1 Roofmounted system system size is 5KWac/6.55KWdc. Scope of work is 23 modules (Hanwha Q-Cell Q Plus 285) with optimzers (SE P320) and a central inverter (SE5000H-US) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30238	13041-20000-22744	1946 S WESTHOLME AVE PV-1	90025	5	129B157   385	4317005012	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.05146	-118.42717	PV-1. Plan check due to 50A branch circuit. ONe 6.5kW inverter and one 2.5kW inverter for 9kW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30239	11041-20000-14010	400 S HOPE ST 5th floor	90071	9	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for T24 Energy (general/emergency) lighting for office TI 5th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30240	14041-20000-21422	9121 N OAKDALE AVE #101	91311	12	198B113   153	2761001068	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.23622	-118.56725	4, 832 SQ. FT. 1st floor TENANT IMPROVMENT ON SUITE 101. PC FOR T24 ENERGY ONLY. PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS. RELOCATION OF LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30241	19041-20000-27824	528 N ERSKINE DR	90272	11	126B125   537	4413019007	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.04175	-118.53369	PV1.  Install 16.575 kW DC / 15.077 kW AC roof mounted grid tied PV system.  (51) modules with 11.4 kW rated inverter.$33.63 permit fee per State Senate Bill SB 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30242	14041-10000-19803	8946 S SEPULVEDA BLVD	90045	11	093B165    20	4123001028	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	33.95482	-118.39596	plan check for energy only (2013 standards). emergency lighting installed. BLDG#14016-10-14484: BANK OF AMERICA ATA INSTALLATION.  NEW 24-HOUR ATA/ATM VESTIBULE.  NEW ATA EQUIPMENT AT EXISTING TELLER LINE.  REDUCE TELLER LINE/MODIFY BANDIT BARRIER.  NEW ADA COMPLIANT COUPON BOOTH.  REWORK EXISTING RAMP FOR ADA COMPLIANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30243	14041-10000-05497	6001 N TOPANGA CANYON BLVD 2ND FLOOR	91367	3	177B101   144	2146025***	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.17941	-118.60612	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOMS FOR WELLS FARGO. 2ND FLOOR. 389 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30244	14041-20000-19561	26323 S PRESIDENT AVE	90710	15	033B193   711	7411024056	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	33.78287	-118.30413	PV1Microinverter standard plan. Install roof-mounted solar array on SFD. System size: 3.36kW(14) EnPhase M250 microinverters(14) Sun Edison SE-F275KyC-2x pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30245	16041-10000-03586	11016 N CARDAMINE DR	91042	7	210B197   344	2552035021	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.26898	-118.29717	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.7KWdc/2.15KWac. (10)MODULES-SUNEDISON R-270-CZC(10)MICROINVERTERS-ENPHASE M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30246	18041-10000-20080	13160 W MINDANAO WAY Suite #184	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Issued	06/01/2018 12:00:00 AM	ADDRESS	33.98501	-118.43726	TI IN AN EXTING OFFICE BUILDING IN SUITE #184. TITLE 24 - ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30247	19041-10000-09025	1055 S LA CIENEGA BLVD	90035	5	132B173   572	4332030021	C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.05785	-118.37637	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30248	13041-20000-28010	1800 S AVENUE OF THE STARS #500	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.06095	-118.41786	Change to lighting and receptacles  in an existing high-rise building on the 5th floor.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30249	12041-10000-06559	760 S HILL ST 760-A	90014	14	127-5A209 315	5144014139	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.04446	-118.25547	PLAN CHECK T24 ENERGY FOR NEW LEASING OFFICE, RESTROOM,  AND STORAGE. TI  ON  SUITE   760-A. PERMIT FOR NEW PANEL, BRANCH CIRCUITS, AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30250	17041-10000-04258	3125 N AYLESWORTH PL	90031	1	139-5A223 246	5208007020	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.0761	-118.20829	PC for a PV1 installation at a rooftop of a single family home. New 8 Microinverters rated at 327Watts each. Total size is 2.616 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30251	19041-10000-48858	384 WORLD WAY SPACE M57	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	33.94339	-118.40887	"FIRST TIME TENANT IN SPACE #M57 - COMMERCIAL / RETAIL SPACE IN TERMINAL ""MSC"" IN LAX. INSTALLING PANELS, CIRCUITS & LIGHTS.  PLAN CHECK FOR POWER & ENERGY. AFFECTED AREA: 1,000 SFT ***M57 - SHARPER IMAGE @ MIDFIELD SATELLITE CONCOURSE (MSC)***BLDG PERMIT: 19016-10000-35469"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30252	12041-10000-20461	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.07594	-118.35916	INSTALLATION OF 3 FUEL CELLS TO GENERATE SUPPLEMENTAL POWER FOR FACILITY AND SUPPORTING EQUIPMENT. NEW PANEL, CKTS, AND EQUIPMENTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30253	17041-10000-08978	1840 W COLORADO BLVD	90041	14	162A225   128	5686008003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.13906	-118.20777	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 14150 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30254	19041-10000-49371	110 E 9TH ST 11TH FL-13TH FL	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM	02/25/2020 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TENANT IMPROVEMENT. FULL POWER & ENERGY PC FOR AN OFFICE SPACE. SERVICE SIZE 4000Amp 480Y/277V 3P 4W EXISTING. SCOPE OF WORK INCLUDES 2 NEW 112.5KVA TRANSFORMERS & 3 75KVA TRANSFORMERS WITH NEW EQUIPMENT. TOTAL AFFECTED AREA 95258. (FIRST TIME TENANT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30255	17041-20000-06964	7311 N MURIETTA AVE	91405	2	186B153   632	2216001022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.20349	-118.43907	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.6 KW STANDARD CENTRAL INVERTER PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30256	12041-10001-16434	11726 W PICO BLVD	90064	11	123B149   752	4260030016	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Approved	08/10/2012 12:00:00 AM	ADDRESS	34.03117	-118.44618	Modification to previously approved set of drawings to change fixture type only.  PLAN CHECK ONLY.              <<<<<<<<<REMODELING EXISTING HEALTH SPA-2 EA NEW CIRCUITS FOR LIGHTING AND RECEPTACLE LOADSPLAN CHK IS FOR TITLE 24>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30257	19041-10000-34007	1771 W BLAKE AVE BLDG 9	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/30/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	9 OF 11. BLDG 9POWER PLAN CHECK FOR 1200A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDING AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30258	16041-10000-20662	114 W 60TH ST	90003	9	105B201   553	6005016007	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	33.98503	-118.27462	PV1 SFD TOTAL SYSTEM SIZE 3.01KW AC USING MICROINVERTER SYSTEM WITH 14 MODULES. USING ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30259	12041-10000-15592	5890 W JEFFERSON BLVD SPACE B	90016	10	120B173   380	4205027011	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Expired	10/01/2014 12:00:00 AM	ADDRESS	34.02226	-118.3768	CHANGE OF USE FROM OFFICE (770 SQ FT) TO TAKE-OUT RESTAURANT, NO SEATING.  Load is less than 200A and occupancy load is 8, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30260	14041-20000-04735	1136 W 6TH ST	90017	1	132A207   615	5143024015	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Apartment			02/20/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.05447	-118.26366	plan check for power and energy for an 42 unit adaptive reuse high-rise apartment building. new 800A underground service, not located in methane zone per zimas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30261	15041-20000-14675	8020 S LOYOLA BLVD	90045	11	099B161   729	4113007011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.9651	-118.41653	Plan chek for PV 1 roof mounted 6.0kWac system with 18 modules (Sunpower SPR-327NE) with 1 inverter (6.0kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30262	17041-20001-26751	11807 W LAUREL HILLS ROAD	91604	2	159B169    70	2377004020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM			Reviewed by Supervisor	08/15/2017 12:00:00 AM	ADDRESS	34.13566	-118.38965	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.11.4kW ungrounded system. (40) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30263	13041-10000-21707	725 S FIGUEROA ST SUITE 450	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.04886	-118.26071	TITLE-24 TENANT IMPROVEMENTIN A HIGH-RISE BUILDING. WORK IS DONE ON THE 4TH FLOOR. EMERGENCY LIGHTING WILL BE ON EXISTING EMERGENCY CKT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30264	13041-10000-07527	2254 S SEPULVEDA BLVD	90064	5	126B153   953	4322020025	M2-1VL	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM			PC Approved	03/22/2013 12:00:00 AM	ADDRESS	34.03893	-118.43657	PLAN CHECK FOR ENERGY ONLY T24 FOR 2 STORY OFFICE SPACE. 1451 SQRFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30265	19041-10001-34200	11035 N LEOLANG AVE	91040	7	210B193   576	2552014008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.2698	-118.3064	EXPEDITE FEESPV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE 7.6KWac/6.5KWdc. SCOPE WORK INCLUDES 20 MODULES (CANDIAN SOLAR CS1H-325MS) WITH OPTIMZERS (SEP320) LEADING TO A CENTRAL INVERTER (SE7600A-US), WITH A BATTERY (LG CHEM RESU 10H), AND A CRITICAL LOADS PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30266	14041-20001-23156	19625 W ROSCOE BLVD	91324	12	192B117   721	2783012025	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM			PC Approved	09/04/2014 12:00:00 AM	ADDRESS	34.22054	-118.56091	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 10.8KW AC USING 3 TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. TOTAL OF 55 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30267	12041-20000-28873	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM			PC Approved	11/30/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	Change to lighting to an existing commercial office space on the 42nd floor.  Load is 361 amps, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30268	15041-20000-01143	6245 W FOOTHILL BLVD	91214	7	198B205   184	2571006024	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	PIN	34.24147771	-118.26708506	SERVICE UPGRADE 600 AMPS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30269	12041-10000-05628	112 E 22ND ST bldg 10	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	33.72783	-118.27968	PLAN CHECK POWER AND ENERGY. NEW 600A SERVICE FOR BUILDING 10. FUTURE RETAIL SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30270	17041-30000-36419	1307 N BRONSON AVE	90028	13	144B189    63	5545015023	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			10/10/2017 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.09466	-118.31811	Plan check for power and energy for 6 story 31 units appartment. Total area: 22,189 sq ft. fire alarm variance has NOT been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30271	19041-10000-22220	500 W ANAHEIM ST	90744	15	030B205   451	7416026026	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM			PC Info Complete	07/08/2019 12:00:00 AM	ADDRESS	33.77949	-118.26788	PC FOR T24 PER INSPECTORS REQUEST FOR CHANGE OF USE FROM A MARKET TO A ICE CREAM PALOR. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND EQUIPMENT. TOTAL AFFECTED AREA IS 1600 SQFT. NOTE: PERMIT FEES WERE PAID UNDER 19041-10000-14884	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30272	11041-10000-11559	515 S FIGUEROA ST 12th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM			PC Approved	06/06/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	Ti in a corridoor area of an office Bldg. EPC is for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30273	16041-20000-10433	18722 N LEMAY ST	91335	3	180B121   312	2126035021	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.19074	-118.54138	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30274	15041-10001-26193	1355-1357 S ABBOT KINNEY BLVD	90291	11	108B145  1290	4239027014	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM			PC Approved	01/12/2016 12:00:00 AM	ADDRESS	33.99081	-118.46608	(1/11/2016)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 6.  CHANGES INCLUDE REVISIONS TO THE LIGHTIGN FLOOR PLAN AND ENERGY CALS.  THIS IS PLAN CHECK ONLY.TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 1612.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30275	12041-10000-16266	7122 N AMIGO AVE	91335	3	183B121   252	2126006017	(T)(Q)RAS3-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			07/13/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.20004	-118.53846	14 unit apartment bldg, 3 story , type V.  variance  to be filed in order to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30276	16041-10000-21080	14710 W VINCENNES ST	91402	6	198B149   219	2650029002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.24015	-118.45417	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.0KWac.(34)MODULES-SUNPOWER SPR-E20-327(1) INVERTER-SMA SB5000TL-US-22(2)INVERTER-SMA SB3000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30277	17041-20000-42949	840 N OGDEN DR	90046	5	141B177    49	5527004004	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Re-Activate Permit	10/09/2018 12:00:00 AM	ADDRESS	34.08657	-118.35935	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6.6 kWac and consists of (1) inverter, (25) modules, (1) load center, and (1) battery unit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30278	13041-10000-30735	9700 N LAUREL CANYON BLVD RESIDENCE-CENTER	91331	7	201B161   612	2626005032	[Q]C1.5-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	Apartment			11/04/2013 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.24593	-118.41825	"ADDITION OF A NEW RESIDENCE CENTER TO AN EXISTING 80-UNIT APARTMENT BUILDING. A NEW 200A UNDERGROUND SERVICE WILL BE FEEDING THIS RESIDENCE CENTER, PER APPLICANT. SITE IS LOCATED IN METHANE BUFFER ZONE. TOTAL ILLUMINATED AREA IS APPROXIMATELY 2189 (INDOOR+OUTDOOR). 1 LIGHTING CONTROL PANEL + (1) 225A PANEL ""RC"" NOTE: SEPARATE SERVICE VARIANCE MUST BE FILED AND LETTER FROM DWP FOR THE SECOND SERVICE MUST BE PROVIDED;"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30279	10041-10000-16723	2029 S CENTURY PARK EAST 12TH FLR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN AN EXISTING OFFICE AREA ON THE 12TH FLOOR.  PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30280	18041-10000-49161	9124 N WOODMAN AVE	91331	6	198B153  1022	2642030021	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.23604	-118.4407	PC FOR RETAIL , T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30281	18041-10000-08971	521 N KENTER AVE	90049	11	135B137   197	4426037015	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.0682	-118.48656	PC for 5.76kW(ac) PV solar system for SFD. Installing 16 AC modules with load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30282	18041-10000-06268	888 S FIGUEROA ST #600	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.0465	-118.26225	NON-STRUCTURAL T.I. TO (E) OFFICE SPACE; PARTITION DEMO, NEW INTERIOR PARTITIONS, LIGHTING FIXTURE RELOCATIONS, FINISHES (8,797 SQ FT TOTAL)PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30283	13041-10000-04233	12223 W SANTA MONICA BLVD	90025	11	126B145   755	4263027017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.04001	-118.46529	New electrical system and lighting for existing convenience store. 1992 sqrft. Service upgrade with new branch circuits and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30284	15041-20000-33586	10250 W CONSTELLATION BLVD #1270	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 only on existing high-rise for Affordable Housing. Total area: 3,630 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30285	17041-10000-27626	3201 N LACY ST	90031	1	142-5A221 279	5205002902	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.08349	-118.21854	TEMPORARY POWER FOR PORTABLE BUILDINGS ONLY. NEW SUGGESTED TEMP POWER RATED AT 800A 120/208 V.  APPLICANT NOTED THAT THE BUILDINGS ARE PRE FABRICATED AND  STATE APPROVED.( THE APPLICATION 13041-10000-34763 HAS BEEN EXPIRED WITH THE SAME SCOPE FOR THIS BUILDING)BUILDING PERMIT # 13014-10000-04943.  RENOVATION/REMODEL OF (E) ANIMAL CARE FACILITY  ABOUT 5000 SQ ADDITION; NEW PARKING DESIGN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30286	18041-10000-32204	927 N SYCAMORE AVE 1ST FLR	90038	4	144B181   718	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.08796	-118.34291	FIRST TIME TENANT ON THE GROUND FLOOR.PLAN CHECK FOR POWER AND ENERGY.BLDG PERMIT: 18016-20000-27150	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30287	17041-20000-31791	11611 W HART ST	91605	2	183B169   191	2320001023	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM			Corrections Issued	09/06/2017 12:00:00 AM	ADDRESS	34.19768	-118.38506	TI to (E) commercial warehouse space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30288	12041-10003-19659	8407 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Info Complete	11/07/2012 12:00:00 AM	ADDRESS	34.22266	-118.62737	"DELTA 1 CHANGES TO THE APPROVED PLANS.  REMOVE THE ""STAND-BY / OPTIONAL GENERATOR"" ON PAGE E-7.  THE 4 POLE TRANSFER SWITCH WILL BE LOCKED IN ""INHIBIT"" MODE.  ALL EMERGENCY LIGHTS AND EXIT SIGNS IN THE BUILDING ARE ""UNIT EQUIPMENT"" WITH INTERNAL 90MINUTES BATTERY PACKS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30289	19041-20000-05288	15503 W VENTURA BLVD #240	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.15504	-118.4723	Plan check for power and energy. Project site is an existing suite in a commercial building. Project scope is a change of use from office to medical office. Total lighting area = 7,002 sq. ft.Note: Building application has been generated under 18016-10001-07620. See application comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30290	12041-20000-03065	7900 N SEPULVEDA BLVD	91405	6	189B145   465	2209032042	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.21386	-118.46596	Install outdoor lighting on lighting poles (3 poles) in parking area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30291	13041-10000-20930	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	PIN	33.92817449	-118.43220714	PC FOR POWER ONLY AT HYPERION TREATMENT PLANT (truck loading odor control modernization). More than 400A connected load. REPLACE MOTORS, INSTALL LIGHTING OUTDOOR, AND 2 RECEPTACLES. INSTALL COntrol panels. No work being done in hazardous locations per applicant. Industrial facility per applicant and exempt from outdoor T24 wattage; to be verified during plan check. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30292	14041-10001-21369	2630 N HARLESDEN CT	90046	4	153B173    14	5569002003	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	34.11959	-118.36882	Plan Check only. SIGNIFICANT CHANGES TO PLANS SINCE INITIAL SUBMITTAL WAS INCOMPLETE. Changes include homeruns and circuits and floor plans for house and guest house. permit to be pulled on original permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30293	12041-20000-11017	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM			PC Approved	05/14/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI for an existing office. Plan check for energy only. 512 sqft. High rise office building. 26TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30294	16041-10000-36385	5022 N MECCA AVE	91356	3	171B125   846	2184001009	RA-1	South Valley	Encino - Tarzana	Tarzana		1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.16155	-118.53733	PC FOR PV SYSTEM TOTAL SYSTEM SIZE 4.3KW AC USING 18 MODULES AND USING ENPHASE MICROINVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30295	15041-10000-03003	930 E PICO BLVD	90021	14	123A211   249	5132018011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.03068	-118.24953	PC FOR POWER AND ENERGY. EXISTING BUILDING NEW ELECTRICAL SERVICE. MANUFACTURING BUILDING , 4 TENANT. TOTAL AREA7025 INDDOR+ 7200 OUTDOOR SQ. PER APPLICANT CALCULATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30296	15041-10000-08407	12723 W WENTWORTH ST	91331	6	198B161   319	2629027017	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Expired	04/17/2017 12:00:00 AM	ADDRESS	34.23711	-118.41145	T. I. TO (E) OFFICE/WAREHOUSE/MANUFACTUREING BUILDING.  Separating one tenant space into two spaces. WITH THE SERVICE EXISTING, CHANGING SWBD TO HAVE 2 EA 1200A SECTIONS AND 2EA 800A SECTIONS; RECONNECT FEEDERS TO NEW SWBD;NOCHANGES TO EQUIPMENT DOWN STREAM FROM THE SWBD. ALL TO ACCOMODATE NEW TENANTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30297	19041-10000-11365	800 S SAN PEDRO ST	90014	14	126A211   366	5146025047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Issued	03/29/2019 12:00:00 AM	ADDRESS	34.03822	-118.24912	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30298	13041-20001-16279	9160 N DEERING AVE	91311	12	198B105   148	2746010032	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.23739	-118.59594	Skylight was found in field. Plan check for energy for warehouse space only. Addition of daylight controls for skylit area. 13554sqft.RENOVATION OF OFFICE SPACE. OFFICE AND WAREHOUSE SPACE. PC FOR T24 ENERGY ONLY. TOTAL AREA 19121 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30299	15041-20000-16804	9301 N TAMPA AVE #25	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only for Vanity District Salon(Chnage of use from Retail to hair salon). Total area: 942 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30300	17041-30000-41188	590 N VERMONT AVE 1st Floor	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Info Complete	11/21/2017 12:00:00 AM	ADDRESS	34.08157	-118.2915	Plan check for Title 24 only in existing space T.I. class room Total area: 4,755 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30301	14041-20000-24878	7014 S HOOVER ST UNIT 2	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 2.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30302	12041-10000-29331	8126 S NAYLOR AVE	90045	11	099B165  1045	4107003018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	33.96437	-118.39527	PV1 SINGLE STORY ROOF MOUNTED SOLAR INSTALLATION. INTERCONNECTED WITH MAIN SERVICE PANEL. SYSTEM SIZE IS 5.50 KW. TWO STRINGS WITH 25 MODULES AND USING TRANSFORMERLESS INVERTERS [INVERTER: SOLAREDGE # SE5000A-US ||||| PV MODULES: KYOCERA # KD220GX-LFBS]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30303	14041-20000-00395	7745 N RHEA AVE	91335	3	189B121   589	2103018008	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.21161	-118.5416	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 6.48KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30304	15041-20000-33057	350 S GRAND AVE Suite 3950	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for Title 24 only. Project site is a suite on the 39th floor of an existing, commercial high-rise building. Total lighting area = 4,370 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30305	16041-10000-16538	3410 W SAN FERNANDO ROAD #1	90065	13	153B209   115	5458003027	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.11875	-118.25083	PC for energy only. Remove HID fixtures and replace with new LED fixtures. Total sq ft = 29529	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30306	18041-10000-31239	505 E 3RD ST	90013	14	129A215   217	5161020015	R5-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.04638	-118.23985	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30307	13041-10003-12486	7203 N RUBIO AVE	91406	6	183B137    51	2226016015	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			06/10/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	ADDRESS	34.20163	-118.49594	PC FOR POWER/ENERGY. NEW 29 UNIT APT.4STORY.1ST FLOOR grade level  AND 3 STORies above. 8 typical units. not methane . fully sprinklered. engr = robert tomasianCONSTRUCT NEW 29 UNIT APT AND SALE OFFICE AS AN ACCESSORY USE TO THE BUILDINGNO PROGRESS - PC APPROVE IS FOR GRADING PERMIT R&R ONLYchanges made to previously approved set , changes to outdoor lighting, outdoor title 24, bath room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30308	10041-20000-19709	357 N SUMAC LANE	90402	11	123B129   460	4410024006	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.03325	-118.51403	Roof mounted P.V.  system single family over 10kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30309	19041-10001-30028	1003 E 4TH PL 8th flr	90013	14	127-5A217  55	5163018002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Issued	01/08/2020 12:00:00 AM	ADDRESS	34.04219	-118.23383	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATION TO LIGHTING SYSTEM AND UPDATE TO SINGLE LINE DIAGRAM - NO NEW LOAD WAS ADDED FROM ORIGINAL PERMIT - CHANGES UNDER DELTA D ONLY(BULLETIN #1)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30310	15041-10000-42588	10408 N NEWHOME AVE	91040	7	204B189   176	2560002001	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM			Not Ready to Issue	12/17/2015 12:00:00 AM	ADDRESS	34.25812	-118.32149	PV1, ROOF MOUNTED SYSTEM USING MICROINVERTERS. (24) MICRO-INVERTERS ENPHASE M215-60-2LL-S22-I6 (24) CANADIAN SOLAR CS6P-250P. PERMIT IS BEING PULLED UNDER AN OWNER'S BUILDER ON PERMIT #15041-10000-42609.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30311	19041-20001-29584	2055 N WEST SILVER LAKE DR	90039	4	147A207    55	5431019001	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM			PC Approved	08/16/2019 12:00:00 AM	ADDRESS	34.09629	-118.26673	Plan check for installation not conforming to online permit single line design.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30312	16041-10000-05637	9107 W SAWYER ST	90035	5	126B169    28	4305028035	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.04537	-118.38831	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.0KWac. (42)MODULES-LG LG300N1K-G4(2)INVERTERS-ABB PVI-6000-OUTD-US-A(1) 100A SUBPANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30313	12041-10000-21920	224 W 1ST ST	90012	14	130-5A213   7	5149001007	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Info Complete	09/14/2012 12:00:00 AM	ADDRESS	34.05321	-118.2452	TI IN AN EXISTING COMMERCIAL BUILDING, ON THE THIRD FLOOR OF THE LA TIMES WEST BUILDING. CIRCUITS AND LOADS HAVE BEEN REVISED. THE TOTAL CONNECTED LOAD TO THE SERVICE HAS BEEN REDUCED.  PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30314	11041-10000-02762	8905 N GLENOAKS BLVD BLDG A	91352	6	195B173   278	2408008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.23033	-118.36723	CHANGE OF USE FROM A LAUNDROMAT TO A RETAIL  BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30315	11041-20000-17852	9454 N GIERSON AVE	91311	12	198B101    50	2727020020	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Expired	10/15/2013 12:00:00 AM	ADDRESS	34.24241	-118.61131	New roof mounted 12.88KW Photovoltaic system and includes upgrading main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30316	15041-10002-18693	1055 S SERRANO AVE	90006	10	129B193   587	5080014003	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			03/13/2017 12:00:00 AM			PC Approved	04/24/2017 12:00:00 AM	ADDRESS	34.05106	-118.3065	Supplemental for recheck of lost set. Original set under 15041-20000-18693. Permit is pulled under original application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30317	13041-10000-32405	16653 W HAMLIN ST	91406	6	180B137   483	2231013023	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.18859	-118.49646	PV1, Install 4 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter: Solaredge SE3800A-US. 16 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30318	16041-10007-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	Changes to an approved set of plans. All changes are clouded under Delta 20. Changes include adding an additional lighting circuit, revising lightin floor plans due to bike storage area, revising title 24 calculations, and revising emergency photometrics.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30319	16041-10000-39193	638 N SIENA WAY	90077	5	141B153   156	4362001022	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM			PC Info Complete	07/05/2017 12:00:00 AM	ADDRESS	34.08263	-118.44568	New single family home. Installing new electrical equipment. New Service rated at 1200 Amps 208/120V 3phase 4Wire. **Note:  Electrical permit fees have been charged under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30320	11041-20000-01591	4551 S GLENCOE AVE Ste# 140	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	33.9844	-118.43407	Plan check T24 Energy (general/emergency) lighting for Interior tenant improvements in (E) office suite 140.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30321	11041-20000-04825	21300 W VICTORY BLVD #1200	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM			PC Approved	03/25/2011 12:00:00 AM	ADDRESS	34.18813	-118.59618	T.I. to a high rise building of 12th floor.  Relocate and install new lightings.  Plan check for energy only.Note: Permit issued under 11041-90000-03055	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30322	14041-20000-35920	5363 N BALBOA BLVD #121	91316	5	171B133    38	2258027016	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	34.16893	-118.50129	TI TO AN EXISTING MEDICAL CARE COMMERCIAL BUILDING.  NO CRITICAL CARE NOR LIFE SUPPORT EQUIPMENT WITHIN SCOPE OF WORK.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN THE FIRST FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30323	16041-30000-38995	1439 N TAMARIND AVE	90028	13	147A191   121	5545014011	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.09675	-118.3192	Plan check for Fire Alarm System in 21 Units 4 story building. Total Fire alarm devices: 110 and 1 fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30324	19041-20000-52397	22222 W VENTURA BLVD	91364	3	171B101   111	2075001033	(Q)C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	10/19/2020 12:00:00 AM		Permit Finaled	11/18/2020 12:00:00 AM	ADDRESS	34.16855	-118.61119	PV3.  Install 107.6 KW DC/97.117 KW AC CEC roof mounted PV system.  (269) modules with (4) 20 KW inverters and a 200 panel.$0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30325	19041-10000-20513	2814 W MARTIN LUTHER KING, JR BLVD	90008	10	114B189   342	5023003016	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.01071	-118.32385	Energy plan check for outdoor, removing HID fixtures and replace with new LED fixtures T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30326	14041-10000-09932	2511 W 3RD ST	90057	13	135A203    96	5155033018	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.02	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.06525	-118.27685	"Replacing two existing (600 Amp & 200 Amp) feeders from the Pull Section to Meter Section due to fire damage Like to Like.  The total length of each feeder is about 20 feet.  Unprotected conductors shall not be installed on the roof of this building.  The feeder to 600 Amp panel is 2 sets of 3 # 400MCM in 3"" conduits, and the 200 Amp feeder has 3 #4/0 in a 2 1/2 conduit."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30327	19041-20000-51522	11578 W DONA EVITA DR	91604	2	159B169   579	2381013011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.13026	-118.38552	PV1. INSTALL 12.6 KW DC PV SYSTEM WITH (36) MODULES, OPTIMIZERS AND (1) INVERTER (SE11400)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30328	17041-10000-10202	424 N WESTERN AVE	90004	10	138B193    45	5521015031	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.07851	-118.30892	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 62350 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30329	14041-10000-30127	17630 W CHATSWORTH ST	91344	12	207B129   467	2733009005	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.26464	-118.51864	Medical: full plan check for  dental office T.I with new panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30330	18041-10001-41569	11055 W BURBANK BLVD	91601	2	174B173  1381	2337029028	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1242.04	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	12/27/2019 12:00:00 AM	ADDRESS	34.17235	-118.37235	Plan check for changes to approved set, all changes are clouded under delta C. Tenant Improvement to existing restaurant. Scope includes new light and receptacles. Total affected area is 2143 B#18016-10000-35160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30331	08041-10002-17061	975 N VENDOME ST 1-36	90026	13	142-5A203 305	5426016003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.01	Electrical	Electrical	Apartment			01/31/2011 12:00:00 AM	04/28/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.08417	-118.27465	"Change the priviously approved plan. Addition of HVAC system on the roof. EPC is for power.  ((((((((((((((((((((EPCTi in 36 units appartment building. Electrical plan check is for power and Energy. ( Fee is not included T24 for outdoor and ""House panel"" branch circuits.)))))))))))))))))))))))))) To comply w/ department order dated 4/16/07.  Permit will expire 30 days from issuance date."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30332	18041-10000-03944	2801 W SUNSET PL	90005	10	133-5A201  78	5077013036	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	02/25/2022 12:00:00 AM	ADDRESS	34.0609	-118.2845	PC FOR A NEW 23 STORY HIGH RISE RESIDENTIAL TOWER AND PARKING STRUCTURE. SCOPE INCLUDES 455 UNITS. TOTAL AFFECTED AREA IS 196267 Sq.Ft. (2) SERVICE AT 5000A, 277/480V, 3PH, 4W EACH PER ARTICLE 230.2(C), (2) FIRE PUMPS, (4) ATS, (2) 4000A BUSWAYS, PROJECT IS LOCATED ON METHANE ZONE.FA MODIFICATION HAS BEEN SUBMITTED WITH THE DEPARTMENT. 02/02/2018NOTE: SCOPE DOES NOT INCLUDE THE 189 PHASE B UNITS.B# 16010-10000-04209	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30333	14041-10000-08243	10800 W PICO BLVD 322	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.04054	-118.4272	T24 FOR EXISTING SUSHI RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30334	16041-10001-06713	11200 N CORBIN AVE Suite 200	91326	12	210B117   384	2701040027	(Q)C1.5-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.27517	-118.5618	03/31/16Changes to an approved set of plans. All changes are made under delta 2. Changes include removing/adding lighting fixtures for office space 224 and 225. Also adding new receptacles. NOTE: Permit pulled under PCIS#16041-30000-06713((((Title 24 plan check only.  Total area = 4,294 sq. ft.     T.I. to existing two story office building.  Two new subpanels + new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30335	15041-20001-11903	12446 W OSPREY LANE Unit 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	33.97949	-118.41001	Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (8) modules, and (1) inverter. This is Unit 3 of 3.Note: PV solar clearance shall apply to the three units under this PCAM number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30336	17041-10000-16182	4126 S ARLINGTON AVE	90008	8	114B189   539	5022017049	[Q]R4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress Central Area		2340.00	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.00987	-118.31807	T24 ONLY, REPLACE (E) LIGHT FIXTUES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  27900 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30337	19041-20001-52786	8405 S PERSHING DR	90293	11	096B153   927	4116023022	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM			PC Approved	02/07/2020 12:00:00 AM	ADDRESS	33.95705	-118.4431	Expedited plan check fee. PV3.  Install 22.62 kW DC roof mounted grid tied PV system.  (58) modules with (2) 7.6 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30338	14041-10000-01557	4661 W WILSHIRE BLVD	90010	4	135B185   569	5505007017	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			01/17/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.06213	-118.33079	Installation of new addressable fire alarm system in (N) 12-unit 3-story condominium building.  72 devices with Edwards VS2 FACP and remote annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30339	19041-20000-30740	555 S FLOWER ST 13TH FL	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	T24 ENERGY PLAN CHECK ONLY FOR 13TH FLOOR OF EXISTING COMMERCIAL BUILDING. TI TO ELEVATOR LOBBY, LA ROOM, AND A BOARD ROOM. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2460 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30340	17041-10000-19424	1355 S HILL ST	90015	14	124-5A207  89	5134025020	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	34.03646	-118.26342	PLAN CHECK FOR T-24 ONLY - REPLACE EXISTING FIXTURES WITH NEW (12)LED FIXUTES - TOTAL AFFECTED AREA (5730)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30341	12041-10000-10973	5811 S SAN PEDRO ST	90011	9	108B205  1113	5101021001	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	33.98946	-118.2703	REMODELING OF EXISTING OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30342	18041-10000-47349	2218 W LOVELAND DR	90065	1	151-5A219  70	5462018012	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.11091	-118.22371	Plan check for a PV1 8kW AC roof  mounted system with (25) AC modules interconnecting through a subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30343	18041-20000-30152	3446 N CLAIRTON PL	91436	5	159B137   298	2293016002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.13293	-118.49386	Plan check for the addition of (1) Tesla PowerWall onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30344	11041-20000-00711	10250 W SANTA MONICA BLVD #616	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	Plan check for new 600A feeder to future tenant (space#616). Panel and loads will be provided others.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30345	18041-20000-33075	3432 W SUNSET BLVD	90026	13	144A203   273	5427026007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Issued	09/05/2018 12:00:00 AM	ADDRESS	34.08822	-118.27643	Plan check for Title 24 only in existing space retail T.I. total area:1338 sq ft. B#18016-20000-27861	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30346	14041-20000-12313	627 N MCCADDEN PL	90004	4	141B185   703	5524018014	R1-1-HPOZ	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.08268	-118.33754	Roof mounted PV sysem with enphase microinver, model M215-60-.  System size 2.55KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30347	19041-10000-08373	1415 S REEVES ST 1-4	90035	5	132A167   269	4306002008	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			03/08/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.0547	-118.39672	NEW FIRE ALARM SYSTEM IN A NEW APT BUILDING. (1) FACP, (171) devices, (5) RPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30348	15041-10001-03690	619 N BRITTANIA ST 1-3	90033	14	130-5A223 309	5175032022	R3-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			02/06/2015 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.05116	-118.21231	Supplemental application for expedite fees.Installation of roof mounted solar PV array.  Total system size = 3.3 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30349	17041-20001-01693	7672 N COLDWATER CANYON CT	91605	2	186B161   647	2303020078	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.2102	-118.41475	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30350	17041-20000-30159	703 N BRIDEWELL ST	90042	14	154-5A235 275	5493034012	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Issued	11/16/2017 12:00:00 AM	ADDRESS	34.1165	-118.17134	Plan check for power only. New 800A 120/240V 1ph 3w service to serve 9 new SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30351	15041-10000-19615	2968 W 6TH ST	90005	10	135A201   140	5077007001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Closed	08/09/2017 12:00:00 AM	PIN	34.06352386	-118.28606577	FULL PC REQ., NEW APARTEMENT BLD. 6 LEVELS, 396 UNITS, OVER 3 LVL OF TYPE 1 PARKING STRUCTURE.52,748 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30352	17041-30000-45639	1278 S WESTWOOD BLVD	90024	5	132B153   555	4325005025	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.05737	-118.44279	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a change of use from retail to veterinary clinic/tenant improvement. Total lighting area = 2,855 sq. ft.Note: Building permit has been issued under 17016-20000-08485. Partial permit fees have been paid for under 17041-20000-19380.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30353	19041-10000-53666	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	04/01/2021 12:00:00 AM	ADDRESS	34.08469	-118.4849	PER AB1414 & SB 1222 FESS ARE $0.00(E-PLAN)NEW PV2 ROOF-MOUNTED INSTALLATION FOR AN EXISTING 2500 AMP SERVICE. SCOPE OF WORK INCLUDES INSTALLTION OF:- 433 MODULES (Q.PEAK DUO L-G5.3 400)\- 217 (P850) OPTIMIZERS- 3 se 14.4KUS, 2 SE 43.2KUS & 1 SE9KUS CENTRAL INVERTERSSYSTEM SIZE: 170.1 KW DC; 129.2 KW AC; 161.2KW CEC AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30354	19041-20000-31203	521 W 42ND PL	90037	9	114A201   180	5019015011	RD2-1	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.00635	-118.28354	Plan  check for PV system installed into existing PV, Addition system: 3.0KW DC, Total new system size: 6.0KW. 1 addtion inverter(3.0KW) and 10 PV Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30355	14041-10000-05796	6922 W HOLLYWOOD BLVD	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.10137	-118.34103	REPLACEMENT OF 4000A MAIN AND 1600A MAIN SWITCHES. NO CHANGE IN THE EXISTING LOADS; AIC RATINGS SIMILAR TO THAT OF ORIGINAL MAIN SWITCHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30356	15041-20001-14837	13400 N GLENOAKS BLVD	91342	7	225B145   115	2502028020	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM			Reviewed by Supervisor	06/03/2015 12:00:00 AM	ADDRESS	34.31591	-118.46014	Expedite per applicant request********Plan check for PV roof mounted 13.8kW system with 53 modules (Kyocera) and 2 inverters(5.0kW and 6.0kW) connected to load center 125A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30357	17041-20001-40465	16241 W SCHOENBORN ST	91343	12	192B137   243	2689005010	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.22245	-118.48698	PV1.  Install 11.895 kW DC roof mounted grid tied PV system.  (39) modules with 11 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30358	16041-20000-45620	13335 W VENTURA BLVD	91423	4	165B157   781	2360011018	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.14694	-118.42371	New fire alarm system for single-story daycare center.  (N) FACP with (27) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30359	10041-20000-09308	725-727 W 32ND ST	90007	8	120A201    24	5123011011	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.02476	-118.28144	FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30360	16041-10001-08434	11115 N LAUREL CANYON BLVD	91340	7	210B149   706	2613025053	[Q]C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM			Reviewed by Supervisor	03/22/2016 12:00:00 AM	ADDRESS	34.2721	-118.44668	EXPEDITE PER APPLICANT REQUEST. (((PV2. Plan check for a PV2 system. System size is 406KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30361	17041-20002-41502	737 S LONGWOOD AVE	90005	4	132B185    95	5507029007	RS-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM			PC Approved	07/05/2019 12:00:00 AM	ADDRESS	34.06091	-118.33708	PLAN CHECK ONLY, SUPPLEMENTAL CHANGES TO APPROVED SET. REMOVAL OF A METER AND RELABELING OF MDP SIZE AND ADDITION OF AC CEC VALUE TO FRONT PAGE. MINOR CHANGES MADE TO SINGLE LINE, SIGNAGE PAGE, ROOF LAYOUT PAGE, AND CALCS. CLOUDED DELTA C CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30362	15041-10000-07422	7426 W 82ND ST	90045	11	096B157   232	4114016003	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	33.96209	-118.42748	PERMIT FEE $5.71 BY STATE SENATE BILL NO. 1222PV1, ROOFTOP MOUNTED PV SYSTEM, 5.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30363	12041-20000-20919	4700 N LOUISE AVE	91316	5	168B133   426	2289009015	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM			PC Approved	09/05/2012 12:00:00 AM	ADDRESS	34.15474	-118.50947	Plan check for change from Cu to Al for feeders only. NO OTHER CHANGES AUTHORIZED BY THIS PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30364	13041-10001-13915	685 S NEW HAMPSHIRE AVE	90005	10	132B197   143	5094008004	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			06/03/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.06041	-118.29315	REVISIONS TO PERMITTED SET OF PLANSPlan check power and for new 7-story 177 unit apartment over 2 level of subterranean parking. Low rise building. 4000A service supplying building. Site located in methane buffer zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30365	11041-10000-05313	5100 E YORK BLVD	90042	14	156A225   348	5478006014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1833.00	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.12084	-118.20463	T.I.  CAFE BAKERY BEING TURNED INTO RESTAURANT.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30366	16041-20001-39328	13548 W CANTARA ST	91402	6	192B157   817	2301003002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.21974	-118.42828	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with 100A MSP.3.8kW ungrounded system. (14) 290W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30367	10041-10000-07796	717 S SAN PEDRO ST	90021	14	126A211   141	5145007016	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	PIN	34.04044534	-118.24747286	CHANGE OF USE FROM BEAUTY SUPPLY MANUFACTURING TO WHOLESALE  FLOWER MARKET WITH 23 SIMILAR OPEN TENANT SPACES ALL UNDER A SINGLE MANAGEMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30368	14041-20000-31416	700 S FLOWER ST 29TH FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR T24 ENERGY ONLY. TI TO 29TH FLOOR. OFFICES. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30369	16041-20000-35692	20026 W OXNARD ST	91367	3	177B113   106	2153005008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.18	-118.56984	Plan check for installation of pv system on SFD, roof-mounted. Interconnect with a 200A MSP.7.6kW ungrounded system. (33) 255W pv modules. Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30370	12041-10000-09821	624 S GRAND AVE #1130	90731	15	015B197   491	7451037001	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Expired	08/21/2014 12:00:00 AM	ADDRESS	33.7382	-118.28999	New 800 S.B., new a/c units, new DC Plants (DC Rectifiers).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30371	18041-10000-12886	6200 W 98TH ST	90045	11	093B165   192	4124026010	[T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.94713	-118.3941	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30372	17041-10000-16260	1740 S CRENSHAW BLVD	90019	10	126B185   575	5072002016	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.04243	-118.32944	PC for a PV1 Sytem on a single family residential rooftop. Total size of (21) Microinverter system is 7.035KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30373	10041-20000-21937	15260 W VENTURA BLVD	91403	5	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	12/06/2010 12:00:00 AM	ADDRESS	34.15356	-118.4658	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30374	10041-20000-24484	7500 N CHAMINADE AVE performing-art	91304	3	186B093    52	2027005009	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.20673	-118.63673	fire alarm school performing art building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30375	17041-20001-08276	7412 N BALBOA BLVD	91406	6	186B133   704	2226029004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM			Reviewed by Supervisor	03/31/2017 12:00:00 AM	ADDRESS	34.20514	-118.50093	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30376	16041-20000-11362	12751 W MILLENNIUM #130	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 1,290 sq. ft.Note: Building application has been created under 16016-20000-07153	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30377	14041-20000-27685	6600 N TOPANGA CANYON BLVD UNIT 532-536	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI TO AN EXISTING COMMERCIAL STORGE SPACE UNIT 12.  CONVERTING UNIT 12 TO UNIT 532,533,534,535,536.  ADDING PARTITIONS, LIGHTING AND PLUGS.  PLAN CHECK FOR ENERGY/POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30378	17041-20001-06586	14631 W LIMEDALE ST	91402	6	201B149   679	2650023001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM			PC Approved	03/08/2017 12:00:00 AM	ADDRESS	34.24462	-118.45151	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (32) micro-inverters and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30379	18041-20000-11333	10960 W WILSHIRE BLVD 2nd & 3rd-Floors	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Issued	04/09/2018 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check for Title 24 only. Project site is two floors of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,387 sq. ft.Note: Building application has been generated under 18016-10000-03661	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30380	16041-10000-00887	1020 W 52ND ST	90037	9	108B197   242	5002027020	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Expired	02/08/2018 12:00:00 AM	ADDRESS	33.99496	-118.2923	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(9)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-PVI-3.0-OUTD-S-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30381	13041-20000-24852	14402 W HAMLIN ST	91401	6	180B149   633	2237023020	(T)(Q)RAS4-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.18841	-118.44675	NEW FIRE ALARM SYSTEM FOR APARTMENTS. 87 DEVICES AND 1 PANEL WITH 1 ANNUNCIATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30382	18041-10000-38029	4445 N NOBLE AVE	91403	4	166-5A147  24	2276006021	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.15214	-118.46198	REMOVE OUTDOOR HID FIXTRES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30383	16041-10000-29120	3669 S CRENSHAW BLVD	90016	10	117B185    33	5046023005	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.02082	-118.33529	TI TO CHIROPRACTOR MEDICAL OFFICE. PC FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30384	18041-20000-08306	4721 W ST CHARLES PL	90019	10	129B181  1252	5071018007	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.04579	-118.34011	INSTALLATION OF A 600 AMP SERVICE AND SWITCHBOARD FOR A SMALL LOT SUBDIVISION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30385	17041-10000-03414	20900 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Apartment			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.21969	-118.58889	PC for outdoor title 24. Removing HID fixtures and raplaing them with LED ones. Area: 14,690 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30386	13041-20000-00958	18167 W CHATSWORTH ST	91344	12	207B125   224	2715012040	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02, 1112.03	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	34.26468	-118.52781	Plan check for energy only (retail area only, all other areas are existing). Hope of the Valley. 7166sqft. Emergency lights are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30387	19041-10000-05763	401 N STATE ST	90033	14	129A221     5	5174008037	C2-1-RIO-CUGU, [Q]R5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	34.04923	-118.21593	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30388	11041-20000-24802	6960 N VESPER AVE Bldg.A	91405	6	183B149   391	2219026001	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Apartment			11/18/2011 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.19734	-118.45077	New 3 unit apartment building.  Everything is new.  Full plan check.Request for Modification to separate Fire Alarm system filed 02.03.12	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30389	19041-10001-19565	23651 W BLYTHE ST	91304	12	189B093   331	2020007043	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM			PC Approved	06/25/2019 12:00:00 AM	ADDRESS	34.2143	-118.64271	PLANS APPROVAL AND RE-STAMP TO REPLACE A LOST APPROVED SET. Permit fees are paid under the master application. Original Scope: NEW ROOFTOP SOLAR SYSTEM CONSIST OF 26 MODULES (LONGI SOLAR 305) , 26 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE7600H-US).  SYSTEM SIZE IS 7.93KWdc and 7.6KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30390	13041-20000-10307	23355 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.1579	-118.63422	replace 800 ampswitchboard, 3 new panels.  Existing commercial building, single-story. per applicant, all circuits are existing. plan check for main switch gear and panels only. exchnge of 3 panels, like for like. permit for the panels only. no circuits or other utilization equipment to be issued under this application #.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30391	19041-10000-05888	1031 S BROADWAY	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.04041	-118.2583	FULL PLAN CHECK FOR TENANT IMPROVEMENT ON FLOORS 7 & 8 OF AN EXISTING 12 STORY OFFICE BLDG. WITH NO SITE IMPROVEMENTS. WORK INCLUDES NEW CONNECTRED LOAD OF APPROX. 550A TO EXISTING 5000A SERVICE RATED AT 480/277V, 100KAIC. TOTAL AFFECTED AREA = 34618 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30392	19041-20000-38117	20216 W WYANDOTTE ST	91306	3	186B113   808	2114018230	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.20261	-118.57382	PV1.  Install 3.48 kW DC / 3 kW AC roof mounted grid tied PV system. (12) modules with 3 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30393	16041-20002-02256	8433 N WILBUR AVE	91324	12	192B121   411	2784009013	RA-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.22365	-118.54506	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (51) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30394	16041-20000-15742	22074 W BAHAMA ST	91304	12	195B101   121	2010006023	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.23183	-118.60858	Plan check for a PV1 roof-mounted PV system. System size is 6.0 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30395	13041-20000-32427	9859 N SAN FERNANDO ROAD	91331	7	201B165    89	2624019013	M2-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			Reviewed by Supervisor	12/19/2013 12:00:00 AM	ADDRESS	34.24923	-118.40471	New service for a commercial building, new lighting, loads.  Full plan check requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30396	15041-20000-15400	15489 W DUOMO VIA	90077	5	156B145   177	4378036002	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.124	-118.47064	PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service panel.(37) Sunmodule SW 280 panel(37) Solar Edge P300 power optimizers(1) Solar Edge SE 1000A inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30397	17041-20000-02305	8615 N DELCO AVE	91306	3	195B109   449	2781007007	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/25/2017 12:00:00 AM	ADDRESS	34.22674	-118.57864	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30398	15041-20000-38560	7015 N SHADE TREE LANE	91307	12	183B085    86	2031007***	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.1992	-118.65881	PV system.Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. (35) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30399	10041-10000-19265	500 W WORLD WAY TERM 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	12/13/2010 12:00:00 AM	PIN	33.94094587	-118.40577128	REPLACEMENT OF 4 ESCALATORS AT TERMINAL 5 AT LAWASUBMITTOR INSISTS ON PLAN CHK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30400	15041-20000-43773	20819 W HART ST	91306	3	183B109   471	2137019043	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.19752	-118.58688	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (22) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30401	18041-10000-13516	15520 W SHERMAN WAY	91406	6	183B145    99	2222035041	R1-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.20096	-118.47129	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30402	16041-20000-28230	9125 N NOBLE AVE #108	91343	7	198B145   466	2656022248	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.23622	-118.46135	PV1.  Install 3.8 kW AC rooftop mounted utility interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30403	17041-10000-17116	3549 1/2 E SISKIYOU ST	90023	14	121-5A227 300	5188016023	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Expired	03/06/2024 12:00:00 AM	ADDRESS	34.0251	-118.19765	Installation of new roof mounted solar PV array on existing duplex.  Central inverter system.  Total system size = 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30404	11041-10000-21221	10753 N SUTTER AVE	91331	7	207B157  1310	2535030001	M2-1-O	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.26508	-118.41994	NEW SERVICE  FOR AN EMPTY COMMERCIAL BUILDING; LOADS WILL BE INSTALLED UNDER TI  LATER ONLY; NOTE THAT LADWP REQUIRES A SEPARATE UNDERGROUND PULL SECTION WITH GAS SEALS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30405	17041-10000-23608	3361 N ANDRITA ST LOT 4	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 4 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05786	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30406	19041-20000-27143	1122 S WESTWOOD BLVD	90024	5	132B153   211	4363022006	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.06024	-118.4449	Existing restroom remodel.  (2) new lights - Title 24 plan check not required per 141.0(b)(2)(I) exception.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30407	15041-10000-18713	380 WORLD WAY LV 3 T10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Info Complete	06/16/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 249.  SCOPE OF WORK IN LEVEL 3 SPACE T-10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30408	14041-10000-09029	301 N BRISTOL AVE	90049	11	132B137   155	4406007023	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.06059	-118.48921	PV1 ROOF MOUNTED NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 14.9KWAC.**0$ FEES DUE TO 2012 SENATE BILL NO. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30409	16041-20000-45024	4745 N ALONZO AVE	91316	5	168B129   456	2182016004	RA-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	02/11/2017 12:00:00 AM	ADDRESS	34.15681	-118.52153	PV1.  Install 16.90 kW roof mounted grid-tied PV system.  (52) modules with (2) 7.6 kW rated central inverters with power optimizers.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30410	12041-10001-18385	6701 S CENTER DR 850	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	08/16/2012 12:00:00 AM	PIN	33.97892163	-118.39376065	7700 sq ft tenant improvment for an existing office space in a high-rise building.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30411	18041-20000-25796	22624 W CALVERT ST	91367	3	177B097   424	2039017017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.18087	-118.61983	Plan check for a PV1 roof-mounted PV system. System size is 21.6 kWdc/19.2 kWac and consists of (60) AC PV modules and (3) load centers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30412	10041-20000-04215	2513 E 24TH ST	90058	14	118-5A219 143	5168018900	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	06/23/2010 12:00:00 AM	ADDRESS	34.01641	-118.22766	OUT DOOR LIGHTING FOR PARKING SPACE. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30413	17041-20000-02410	12860 W FILMORE ST	91331	7	213B161   865	2533029075	(T)(Q)R2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Issued	02/22/2017 12:00:00 AM	ADDRESS	34.27778	-118.41301	pv1install roof mounted pv system sized 3kw interconnectedw ith msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30414	14041-10000-06624	11135 W VANOWEN ST	91605	2	183B173   182	2319005017	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.19409	-118.37372	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 5658 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30415	17041-20001-10940	13075 W VICTORY BLVD 101	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.18684	-118.41708	06/07/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4. Lighting controls and light fixtures have been revised. All changes have been reflected onto the Title 24 forms.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EXISTING RESTAURANT. 2077 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30416	19041-20000-53697	18809 W FAIRFIELD ROAD	91326	12	207B121   620	2728029051	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Issued	12/30/2019 12:00:00 AM	ADDRESS	34.26206	-118.54333	PV1. INSTALL 11.34 KW DC AND 10.34 KW AC CEC ROOFMOUNTED PV SYSTEM WITH (36) MODULES, OPTIMIZERS AND (1) INVERTER (SE10000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30417	18041-20000-17839	5400 W HOLLYWOOD BLVD Unit B	90027	13	148-5A193 139	5544021029	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.10152	-118.3074	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to office/first time tenant. Total lighting area = 1,240 sq. ft.Note: Building application has been generated under 18016-20000-13411	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30418	19041-20000-06480	11460 W GATEWAY BLVD	90064	11	123B153   550	4260036043	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Apartment			02/22/2019 12:00:00 AM			Verifications in Progress	12/23/2021 12:00:00 AM	ADDRESS	34.03348	-118.44154	PLAN CHECK FOR NEW 5-STORY 129-UNIT AFFORDABLE HOUSING APARTMENT OVER 2-LEVELS OF TYPE IA SUBTERRANEAN PARKING. SCOPE OF WORK INCLUDES(2) 2000A SERVICES, (1) 1000A SERVICE, SEE COMMENTS. MIXED USE APARTMENTBLDG PERMIT #18010-10000-02960	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30419	17041-20001-11887	1021 S WELLESLEY AVE	90049	11	126B145   149	4264021008	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM			PC Approved	04/28/2017 12:00:00 AM	ADDRESS	34.0445	-118.4712	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SYSTEM. SYSTEM SIZE: 11.83 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30420	17041-10000-27359	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.10191	-118.28217	Pc for generator replacement. like for like	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30421	13041-10000-23259	366 E 2ND ST GRND LEVEL	90012	14	129A215   135	5161020028	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	ADDRESS	34.04794	-118.23998	TI FOR EXISTING RESTAURANT. PC FOR ENERGY ONLY. Emergency lighting with generator source.  Unit is connected to a highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30422	19041-10000-17826	1 S LMU DR XAVIER HAL	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	33.96577	-118.42406	PC for T24 only, for a TI/remodel. Scope of work includes new lighting, receptacles, no new panels and renovation to a [partial space in the dining servery.  Note emergency lighting to remain in place.  Total affected area is 733 sqft. BLD# 19016-10000-12857From Bld:((TENANT IMPROVEMENT TO DINING SERVERY (XAVIER HALL) (INTERIOR WORK ONLY, NO CHANGE OF USE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30423	18041-10000-48699	7560 WORLD WAY WEST Delta-GSE	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			12/26/2018 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	PIN	33.93790872	-118.42837934	PLAN CHECK FOR POWER AND ENERGY FOR BRAND NEW STORAGE BLDG @ LAX/DELTA HANGAR. NEW 1600A DISTRIBUTION CENTER WITH ASSOCIATED EQIPMENT CONNECTRED TO EXISTING 3000A 480/277V SERVICE. TOTAL AFFECTED AREA = 20692 SF.MISSING PANELS LPC2 AND LMPC2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30424	14041-20001-04861	2917 E 1ST ST	90033	14	126A225    32	5180020031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.04084	-118.20294	(((EXPEDITE FEES))))PC FOR PV2 COMMERCIAL ROOFTOP SYSTEM. PLANS HAVE BEEN CHANGED FROM ORIGINAL DRAWINGS. DUE TO NEW SOLAR FEE INCENTIVES AND A REDESIGN IN THE SYSTEM, NEW PLAN CHECK HAS BEEN IMPLIMENTED. TOTAL SYSTEM SIZE 40KW AC USING 4 TRANSFORMED INVERTERS INTERCONNECTED TO EXISTING SERVICE SECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30425	16041-30000-38097	305 E 9TH ST	90015	14	126A211   158	5145012026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.03988	-118.25288	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30426	12041-10000-29397	4029 W WILSHIRE BLVD	90010	4	132B189    29	5504017901	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01, 2126.10	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.06188	-118.3155	FIRE ALARM:PANEL REPLACEMENT OF AN EXISTING OBSOLETE EDWARDS 5721B THAT IS NON FUNCTIONAL TO A COMPATIBLE ID64.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30427	19041-10000-36264	17479 W VENTURA BLVD	91316	5	171B129   403	2257016054	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.16159	-118.51341	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30428	17041-10000-17410	11428 W SHERMAN WAY	91605	2	183B169   683	2320001022	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.20103	-118.37983	PC for new fire alarm system with 195 devices, 1 FACP and 4 RPS panels. All clouded  portions where for fire approval purposes and do not represent electrical scope of work; all devices are to be plan checked.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30429	15041-10000-31514	1915 E VIOLET ST	90021	14	123A217    21	5166017010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.03272	-118.23342	T-24. PC FOR ENERGY ONLY. TI ON EXISTINC COMMERCIAL BUILDING (WAREHOUSE). SCOPE INCLUDES  REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA IS 4048 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30430	15041-20000-34024	18521 W ASUNCION ST	91326	12	213B125   477	2872017007	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.27842	-118.5365	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6KWac. (25)MODULES-TRINA SOLAR TSM-250 PA05.05(1) INVERTER -ABB PVI-6000-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30431	14041-20000-00049	18318 W BLYTHE ST	91335	12	189B125   468	2102015050	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.21463	-118.5323	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8 KW AC USING 30 MODULES. 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30432	16041-10000-03828	515 S FLOWER ST FLR 51, 52-& 52M	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	FULL PC FOR AN EXISTING 52-STORY OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS, NEW RECEPTACLES, AND THREE NEW PANELS FOR THE 51,52, AND 52M FLOOR LEVELS. TOTAL AFFECTED AREA IS 36180 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30433	11041-10000-22061	5760 W 96TH ST Admin Bldg	90045	11	093B169   165	4125024026	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	33.94928	-118.38339	NEW FIRE ALARM SYSTEM IN THE NEUTROGNA BUILDINGS.  (THIS PERMIT, 11041-10000-22061 IS FOR THE ADMINISTRATION BUILDING, PERMIT # 11041-10001-22061 WAS ISSUED FOR THE R&D BUILDING AND PERMIT # 11041-10002-22061 WAS ISSUED FOR THE CHEMICAL BUILDING).  THE MAIN FACP IS IN THE ADMINISTRATION BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30434	17041-10002-02866	13705 W VENTURA BLVD	91423	4	165B157   603	2271018008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.14823	-118.43147	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLDE EXPANSION OF TENANT SPACE TO TAKE OVER ADJACENT AREA. INCREASED IN PROPOSED LOAD NOW GREATER THAN 400A. PC FOR FULL POWER AND ENERGY. THIS IS PLAN CHECK FOR FULL POWER AND ENERGY AND PERMIT FOR DIFFERENCE IN WORK. SUBMITTAL/INSPECTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30435	15041-10000-16886	6555 W BARTON AVE 2nd Floor	90038	4	144B185   969	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.08785	-118.33475	PC FOR POWER AQND ENERGY. TI NO CHANGE OF USE,OFFICE. TOTAL AREA 1000 SAQ FT. (PHASE 2 KITCHEN)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30436	19041-10000-48983	111 E UNIVERSAL HOLLYWOOD DR 6 and 8th	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.13855	-118.36112	new lighting in the restroom/corridor on th6 & 8  th floos of office buildingPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30437	16041-20000-27487	10337 N LARAMIE AVE	91311	12	204B113   107	2707023008	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.25841	-118.57297	"""0$ permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 12.0kW with 55 modules and 2 inverters(60.kW) connected to MSP."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30438	18041-20000-07149	1724 N ORANGE GROVE AVE	90046	4	147B177   224	5551008016	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Expired	10/01/2023 12:00:00 AM	ADDRESS	34.10231	-118.36034	Installation of 13.5 kWh energy storage system on SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30439	16041-20000-22565	7655 W SUNSET BLVD	90046	4	147B177   919	5550005022	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.09821	-118.35657	Plan check Title 24 only in existing space theater. New 8 lighting fixtures for the Theatrical performances. Total area: 5,404  sq ft.  Lighting for wattage excluded from Title 24 for lighting for theatrical and other live performances(140.6(a)(3)(C)).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30440	17041-20000-02629	415 N ORANGE GROVE AVE	90036	5	141B177  1434	5527030012	RD1.5-1-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Apartment			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.07869	-118.36051	Plan check for power only. Project site is an existing 16-unit apartment building. Project scope is a 600-amp service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30441	14041-20000-32117	2635 N PARADISE DR	90032	1	139-5A227 108	5209022019	[Q]RE20-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	01/31/2015 12:00:00 AM	ADDRESS	34.0771	-118.19845	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4 KW INTERCONNECTED WITH MAIN SERVICE PANNEL(16)  SUNMODULE SW250 MODULES(16) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30442	19041-10000-10684	1370 N ST ANDREWS PL	90028	13	147A193   187	5544030056	(Q)C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.09641	-118.31076	PC FOR NEW FA SYSTEM FOR A REMODEL OF AN EXISTING TWO STORY BUILDING AND BASEMENT.  WORK INCLUDES ALARM IN PARKING LEVEL AND 60 PODS ON GROUND FLOOR.  TOTAL DEVICE COUNT 334 WITH 5 PANELS (1 FACP AND 4 RPS'S)B #18016-10000-04168	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30443	18041-10000-33072	19916 W ARMINTA ST	91306	3	189B113   907	2106004057	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.21307	-118.56718	4.7 KW AC PV1 roofmounted system with (15) AC modules in addition to an existing PV solar system interconnecting the load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30444	15041-20001-16312	936 S OLIVE ST UNIT 349	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #15 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30445	14041-10001-06727	1712 W 1ST ST	90732	15	018B189   233	7559013013	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	33.74383	-118.31411	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 8 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U(32) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30446	17041-20001-35098	9526 N HUNT CLUB LANE	91311	12	201B097   164	2724011037	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.24356	-118.62166	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.4 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30447	15041-20000-18235	9851 N TOPANGA CANYON BLVD	91311	12	201B101   164	2727012054	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.24962	-118.60626	TI to existing commerical building (fire damage). Plan check for energy only. Adding new lighting including emergency. Total sqft. 1,156.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30448	18041-10000-02206	11401 N SKYLAND ROAD	91040	7	213B189    39	2551004006	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Issued	01/19/2018 12:00:00 AM	ADDRESS	34.27706	-118.31534	NEW GROUND MOUNTED SOLAR SYSTEM, CONSIST OF 30 MODULES(SUNPOWER SPR-E20-327) WITH OPTIMIZERS ( SOLAREDGE P400) AND A CENTRAL INVERTER (SE7600H-US). SYSTEM SIZE IS 9.81KWdc AND 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30449	16041-10000-31792	1541 W WILSHIRE BLVD	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.05529	-118.26949	New fire alarm system for a (5) story apartment building. Scope includes (1) fire alarm panel, (3) power supplies, (1) communication panel and (77) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30450	12041-10000-22042	189 S THE GROVE DR # F-90	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			09/17/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.07125	-118.35662	REMODEL  AN EXISTING RETAIL SPACE TO BE A SEE'S CANDY STORE  AT SPACE  F-90 AT THE GROVEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30451	13041-10000-23041	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	FULL PLAN CHECK FOR POWER AND ENERGY FOR FARMER'S MARKET.Terminal five space T5B.  Unit equipment on the inside of the tenanat space.  Space was used before as Duty free shop withunit equipment on the inside,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30452	18041-10000-03900	6755 N FALLBROOK AVE	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.19268	-118.62408	TENANT IMPROVEMENTS AT A RETAIL STORE IN THE Fallbrook Shopping CenterPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30453	19041-10002-28563	9300 N BALCOM AVE	91325	12	198B129   251	2766006002	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.23917	-118.52141	PLAN CHECK ONLY. CHANGES TO APPROVED SET. RELOCATING 2 INVERTERS, SUBPANEL, MSP, PV METER AND ACD TO MATCH EXISTING CONDITIONS ON THE NORTH-EAST SIDE OF THE RESIDENCE. NO OTHER CHANGES APPROVED UNDER THIS SUPPLIMENTAL.   (((NEW ROOFTOP SOLAR SYSTEM CONSIST OF 63 MODULES (Q-CELL 305) , 63 OPTIMIZER (SE P320) AND 2 CENTRAL INVERTER (SE7600H-US EACH). SYSTEM SIZE IS 19.215KWdc and 15.2KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30454	18041-10001-07466	1824 N HILLHURST AVE	90027	4	150B201  1276	5590018001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.10439	-118.28725	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATION OF LIGTHTING SCHEDULE ONLY - NO ADDITION OF FIXTURES - CHANGES NOTED UNDER DELTA 10 ONLY. PC for T24 only for new lighting in change of use from medical to restuarnat. Installing two new panels, new lights, receptacles and equipment. Total area is 1714 sqft. B# 18016-10000-04257.Note: PC only. Permit under the master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30455	19041-10000-11969	2570 S LINCOLN BLVD	90291	11	108B149  1026	4236031001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	33.99082	-118.44789	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30456	13041-20001-22282	9072 W SHOREHAM DR PV-1	90069	4	144B169   527	5560034008	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.09125	-118.3906	PV-1. Microinverter. 3.225kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30457	10041-20000-03463	1910 N NORTH MAIN ST	90031	14	135A221    24	5410015008	M3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.06588	-118.21938	CHANGE OF USE FROM EXISTING OFFICE (13, 480 SF) TO 10 ARTISTS AND ARTISANS JOINT WORK/LIVE UNITS;   The building is now a low rise residential building.  T24 lighting luminaires need be high efficacy in compliance with Section 150(k) of the 2008 Energy Standard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30458	16041-10002-14945	10220 W RIVERSIDE DR	91602	4	165B177   120	2424006005	[Q]C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM			PC Approved	06/20/2016 12:00:00 AM	ADDRESS	34.15203	-118.35355	[[[6/15/16 CHANGES TO APPROVED T24. CHANGES TO THE LIGHTING FIXTURE, EMERGENCY LIGHTING CONNECT TO INVERTER AND ADDITION OF PANELBOARD]]]PC FOR ENERGY.T.I. to rear office unit to include  patio cover to enlarge office AND ADD NEW RESTROOM. TOTAL AREA 1931 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30459	16041-30000-07602	11729 W BARRINGTON CT	90049	11	135B145   634	4401007008	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.06429	-118.46987	PC for Energy only per inspector. Total area: 920 sq.ft. Permit under 16041-30000-03787<<ADD 4 OUTLET FOR DRYERS, (1) 220 v WATER HEATER OUTLET & 12 LIGHTS.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30460	14041-20000-20204	8956 W WONDERLAND PARK AVE	90046	4	153B169   501	5564019053	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.11469	-118.39031	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 5.2 KW AC USING TRANSFORMERLESS INVERTER. STANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30461	14041-20001-28698	9899 N AMBOY AVE	91331	7	201B157   167	2622018012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	34.25005	-118.42022	EXPEDITEPV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 3 STRINGS. TOTAL OF 18 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30462	16041-10001-09353	2433 E HUNTER ST	90021	14	121-5A217 142	5168031015	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM			PC Info Complete	08/15/2016 12:00:00 AM	ADDRESS	34.02772	-118.22874	8/15/16: Changes to approved set.(1) Panel A&B change from 3-phase to 1-phase.(2) Remove 15HP Vacuum and replace with (N) Panel D, 1-phase<SERVICE UPGRADE TO 800A TO AN EXISITNG WHOUSE BUILDING. ALL PANELS ARE EXISTING. PC FOR POWER ONLY.>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30463	17041-10000-18127	1523 N GOLDEN GATE AVE	90026	13	144A203   142	5429024022	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.08955	-118.27597	PC for T24 only for removal of outdoor metal halide fixture and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30464	17041-10001-18987	2222 N MARAVILLA DR	90068	4	150B181   103	5549013025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	ADDRESS	34.11034	-118.34337	ROOF MOUNTEDPV SYSTEM WITH BATTERY STORAGE. NEW PV SYSTEM RATED 6.6KW AC USING 21 MODULES. BATTERY SYSTEM 5.8KW WITH 13KWH STORAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30465	14041-10000-17504	1027 W WILSHIRE BLVD	90017	1	130-5A207 127	5143025010	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	12/12/2017 12:00:00 AM		Issued	12/12/2017 12:00:00 AM	ADDRESS	34.05196	-118.26214	Plan check power and energy for 9-story live work containing 376-units (approximately 11 typical units) including 3-level garage with retail (shell).  Building supplied with three services from utility. [[[fees based on applicant due to precut check, planchecker to reverify]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30466	15041-10000-04653	7880 W SUNSET BLVD	90046	4	147B177  1004	5551026027	C4-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.09789	-118.36124	Energy plan check for a men & women restroom. Total work area is 271 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30467	14041-20000-22153	10700 W SANTA MONICA BLVD #211	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	TI FOR AN EXISTING COMMERCIAL BUILDING SUITE 211.  NEW LIGHTING, ALL ELECTRICAL EQUIPMENT IS EXISING.  3200SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30468	13041-10000-23178	11845 W OLYMPIC BLVD SUITE 985W	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	PIN	34.03325831	-118.45191172	TITLE-24 FOR TENANT IMPROVEMENT IN A SMALL SPEC SUITE.ADDING NEW LIGHT FIXTURES. HIGH-RISE BUILDING, EMERGENCY CIRCUIT TO BE FED BY EXISTING EMERGENCY CIRCUIT VIA GENERATOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30469	16041-10000-43100	9160 N RESEDA BLVD	91324	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.23686	-118.53588	Plan check for Title 24 only in exising space remove outdoor HID fixtures and replance with LED fixtures. Total area:20,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30470	15041-10000-35607	420 N CENTRE ST	90731	15	018B201   331	7449008023	R2-1XL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Expired	10/26/2017 12:00:00 AM	ADDRESS	33.74634	-118.28337	PV1, INSTALL 1.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(6) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30471	18041-10000-04766	3303 S BROADWAY	90007	9	118-5A205 115	5122007023	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.01979	-118.27355	PC for new FA system in thre story building with subteranean garage. Installing 125 devices, one FACP, two RPS and annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30472	15041-10000-12858	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.06338	-118.20434	PC FOR ENERGY ONLY. USC LECTURE HALL T.I.  OCCUPANT LOAD > 100 ;TOTAL AREA 2210 SQ FT. PER F.Y	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30473	14041-10000-31620	917 N EL CENTRO AVE	90038	13	144B189   957	5534028001	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.08765	-118.32456	Service upgrade from 200A to 600 A. New house panels, and switchgear. Five single family dwellings are being serviced from the same service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30474	19041-20000-50243	586 W CYPRESS AVE	90065	1	144A219   322	5446007027	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	34.08778	-118.22175	PV2 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 2.22 KW DC/1.74 KW AC. SCOPE OF WORK CONSISTS OF (6) PV MODULES WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30475	16041-10000-40275	2032 E MARENGO ST	90033	14	132A225   155	5201014023	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.05638	-118.20741	Plan check for Title 24 only in existing space T.I. Medical office pharmacy. Total area: 758 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30476	10041-20000-00562	7122 W BEVERLY BLVD	90036	5	138B181   432	5513002032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM			PC Approved	01/12/2010 12:00:00 AM	ADDRESS	34.07599	-118.34481	revision delta 1 change three phase delta connection to open delta single ohase 2 wires	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30477	14041-10001-03293	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/02/2014 12:00:00 AM			PC Approved	07/30/2014 12:00:00 AM	ADDRESS	33.94571	-118.38747	Plan check for power and energy. CHANGES TO APPROVED PLANS: delta 3-8 changes are new from the original. Reconfigured layout of equipment, lighting, and circuits. No new additions to single line diagram per applicant. residence inn marriott.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30478	16041-20000-42428	12385 N SAN FERNANDO ROAD #35	91342	7	219B149   648	2611007050	(T)(Q)RAS3-1-CPIO, C2-2D-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.29518	-118.45448	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30479	18041-10002-10568	700 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	PIN	33.94153561	-118.3984113	CHANGES TO AN APPROVED SET UNDER DELTA RFi 4716. SCOPE INCLUDES ADDING TWO FIXTURES FOR AN EXISTING OFFICE SPACE, REVISING EMERGENCY PHOTOMETRICS, AND REVISING TITLE 24 CALCULATIONS. B#18016-10000-03226NOTE: PC ONLY. PERMIT TO BE PULLED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30480	12041-10000-14761	1472 N LAUREL WAY	90210	5	147B161   164	4355015046	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	08/28/2012 12:00:00 AM	ADDRESS	34.09909	-118.41765	INSTALLATION OF A 7.848 KW PHOTOVOLTAIC SYATEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30481	12041-20000-03381	15434 W HART ST	91406	6	183B145   388	2234026025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	ADDRESS	34.19738	-118.46949	Roof mounted 4.93KW PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30482	14041-10000-34509	1165 1/4 S CROCKER ST	90021	14	123A211    15	5132011240	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.03336	-118.25175	T24, REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 462 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30483	16041-10000-38680	3002 W 75TH ST	90043	8	102B189  1928	4009013009	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	33.97174	-118.32552	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING MICROINVERTER SYSTEM WITH ENPHASE M250. USING TOTAL OF 20 MODULES	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30484	14041-10000-04753	21700 W OXNARD ST 18TH FLR	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.17901	-118.60179	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY.  < 400 AMPS. 18TH FLOOR. 6549 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30485	18041-20000-40121	15330 W RAYNETA DR	91403	4	163-5A145  40	2281010004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.14386	-118.46715	Plan check for PV roof mounted system, system size: 18 kW with 50 PV Modules and 2 inverters(7.6kW) connected to 200A Panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30486	14041-20000-29656	6333 W 3RD ST SUITE 134	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	34.07157	-118.36014	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. GREENHOUSE. 1030 SQFT. SUITE 134	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30487	13041-20000-03410	11601 W WILSHIRE BLVD 1830	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM			PC Approved	02/11/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	Plan check for energy and emergency lighting. 1710sqft. Unit 1830.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30488	17041-10000-27815	655 E FLORENCE AVE	90001	9	102B205   533	6007019007	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	33.9749	-118.2637	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY. TOTAL SQUARE FT 48500.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30489	13041-20000-11921	3501 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			PC Approved	05/21/2013 12:00:00 AM	ADDRESS	34.02194	-118.28455	T24 FOR RENOVATION OF THH OFFICE 2ND AND 3RD FLOOR. 5692 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30490	13041-10003-12614	9040 W PICO BLVD	90035	5	132B169   879	4305007029	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	ADDRESS	34.05505	-118.38885	10/20/15Changes to an approved set, note changes on delta 6 and 7. changes include new fixtures, revised T-24 forms and the reversion to 2008 Forms. Building Permit #13016-10000-09593. All permit fees covered under 10001. 10-15-15Changes to an approved set, note changes on delta 6. scope includes new lighting fixtures. T-24 still qualifies under 2008 standards but applicant decided to use 2011 T-24 forms. (((pc for power and energy. CHANGE OF USE FROM EXISTING ONE STORY FURNITURE BUILDING TO AN ORTHODOX SYNAGOGUE INCLUDING PARTIAL DEMO  15215 SF)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30491	19041-20000-27146	2113 W SILVER LAKE AVE	90039	13	148-5A211  66	5438002002	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.10232	-118.25313	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 5.355KW DC/5KW AC. SCOPE OF WORK INCLUDES (17) HANWHA Q CELLS WITH P320 OPTIMIZERS AND A SE5000H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30492	16041-20000-17664	19559 W LOS ALIMOS ST	91326	12	210B117   353	2708007033	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.26784	-118.5596	Plan check for PV roof mounted system. system size: 8.3kW with 26 ACM modules. Standard plan is being use.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30493	19041-10000-30703	5601 W 78TH ST	90045	11	099B173   377	4104021001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	33.96731	-118.37918	PV1. INSTALL (38) ENPHASE IQ7PLUS MICROINVERTER WITH SYSTEM SIZE OF 12.73 KWDC / 11.54 KWAC ON EXISTING 200AMP SERVICE .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30494	12041-10000-26644	6350 W SANTA MONICA BLVD	90038	4	144B185   733	5533016002	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Public Safety Only			11/06/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.0906	-118.32785	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30495	16041-10000-17090	1010 W KNOX ST	90502	15	057B197    26	7351034072	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	33.8541	-118.29433	TI TO OFFICE WAREHOUSE SPACE. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30496	18041-20000-45028	24221 S ROSCOE BLVD	91304	12	192B089   181	2017038013	RE11-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.21965	-118.6548	Plan check for a PV1 roof-mounted PV system. System size is 5.04 kWdc/5.2 kWac and consists of (1) inverter and (16) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30497	16041-20000-42760	3441 N CARIBETH DR	91436	5	159B137   204	2293010012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.13391	-118.49303	PV1.  Install 12.7 kW roof mounted grid tied PV system.  (41) modules with AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30498	18041-10000-12154	1660 W ANAHEIM ST	90744	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	PIN	33.77837751	-118.28848326	INSTALL 10 NEW WELL PUMPS IN CLASS I DIV II LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30499	16041-10001-02204	8463 N AURA AVE	91324	12	192B117   331	2783003014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Expired	03/19/2018 12:00:00 AM	ADDRESS	34.22434	-118.55478	Supplemental changes to approved set: added (2) modules to total of (34), revised rooftop orientation of the modules, revised arrangement of the strings.Fee is zero dollar per CA Senate Bill 1222***PV1INSTALL ROOF MOUNTED PV SYSTEM ( ADDITION TO AN EXISTING SYSTEM) SIZED 7.6KW INTERCONNECTED WITH MSP.(32) HANWHA QCELLS 260 MODULES(32) OPTIMIZERS(1) SOLAREDGE 7600 INVERTER***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30500	10041-10001-04721	5200 W CENTURY BLVD 9TH & 10TH-FLOORS	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM			PC Approved	05/26/2010 12:00:00 AM	ADDRESS	33.94516	-118.37049	INSTALLING NEW CIRCUITS AND ADDING NEW LUMINAIRES FOR NEW STAIRWELL BETWEEN 9TH AND 10TH FLOORS.  EXISTING EM LUMINAIRES AND LIGHTING CONTROL PANEL  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30501	17041-10000-30515	8475 W MELROSE PL	90069	5	141B173   426	5528001057	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.08373	-118.37591	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RESTAURANT TO SMALL CAFE AND RETAIL. SCOPE INCLUDES NEW PANELS, NEW LIGHTS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 2365 SQ. FT. B#17016-10000-14475	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30502	17041-20001-35802	4219 N SHADYGLADE AVE	91604	2	165B165   887	2367007016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM			PC Approved	02/13/2018 12:00:00 AM	ADDRESS	34.14734	-118.40202	02/13/2018 Changes to an approved set of plans. All changes have been clouded. Distribution equipment has been relocated.*****Previous Work Description*****install (2) tesla powerwalls 5kw each.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30503	16041-20001-00451	7500 N ASMAN AVE	91307	12	186B101   396	2022021011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.20648	-118.61671	03/04/2016 Plan check for service load calculations for the MCB derate of the MSP.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30504	16041-10001-31397	1041 W 68TH ST	90044	8	102B197   428	6014020018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2016 12:00:00 AM			PC Approved	09/27/2016 12:00:00 AM	ADDRESS	33.97795	-118.29325	09/27/16Changes to an approved set of plans. Change include adding 2 modules on the single line diagram and on the roof. note: Permit is paid under PCIS#16041-10000-31397(((((((ROOF MOUNTED PVPC FOR PV SYSTEM WITH 3KW INVERTER AC USING 8 PV MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30505	18041-10000-11509	4115 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   250	5045001008	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.01636	-118.3436	New 3-story,  Charter Middle School with classrooms, gym and lunch area. Scope of work includes 2 new 600Amp Services, 480/277V.  letter from LADWP for two services submittedfire alarm variance has been submittedBUILDING PERMIT #  18010-10000-00050	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30506	13041-10000-35396	888 S FIGUEROA ST 11TH FLOOR	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Issued	04/15/2014 12:00:00 AM	ADDRESS	34.0465	-118.26225	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT. HIGH RISE OFFICE. 9TH FLOOR. 9914 SQFT. EMERGENCY LIGHTING.  (Field inspector - see application comments)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30507	16041-10000-39495	1147 E 11TH ST	90021	14	123A213   120	5132007042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.03146	-118.24565	Title 24 plan check.  Remove HID fixtures and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30508	16041-20000-26333	18529 W CALVERT ST	91335	3	177B125   491	2127015026	RA-1-K-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Apartment			07/26/2016 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.18195	-118.53686	NEW 24 UNIT 3-STORY APARTMENT BUILDING WITH BASEMENT GARAGE.  PLANCHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30509	19041-20000-33390	3317 W EXPOSITION PL	90018	10	120B185  1413	5044002012	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.02152	-118.33233	Plan check for Title 24 Energy only in existing Office building Tenant Improvement. Total area: 1553 sq ftNote: one plan for two application number(19041-20000-33386 and 19041-20000-33390)#B19016-10000-22053	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30510	14041-10000-21474	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.0352	-118.45736	Installation of a new fire alarm system with 24-hour system monotoring.  56 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30511	19041-20000-14507	5449 N COSTELLO AVE	91401	2	174B153  1347	2247010028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	PIN	34.17001544	-118.4381109	Plan check for PV and battery back up system installed into existing PV system, PV system size: 4.2KW DC with 7.6KW AC from 1 SE7600 inverter(7.6KW) and 1 battery LG Chem 9.8KWH and (14) mission solar energy  PV Modules with P320 optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30512	19041-10000-51260	11222 N ALTA AVE Lot 9	91345	7	210B145   522	2664027009		North Valley				1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.27419	-118.46887	[E-PLAN] PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) USING 13 MODULES (Q-PEAK 315) AND 13 OPTIMIZERS (P320)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30513	16041-10000-24008	11436 W HATTERAS ST	91601	2	174B169   362	2338024029	(T)(Q)RAS4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Closed	02/16/2021 12:00:00 AM	ADDRESS	34.17559	-118.38041	PC FOR POWER AND ENERGY. NEW 5  STORY 28 UNIT APARTMENT & RETAIL  @ FIRST FLOOR OVER  ONE LEVEL  TYPE I-A SUBTERRA  PARKING GARAGE. TOTAL AREA 21000 SQ FT.B# 15010-10000-01555	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30514	19041-10000-46448	9560 N SUNLAND BLVD	91040	7	201B177   390	2544009***	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM			Reviewed by Supervisor	11/21/2019 12:00:00 AM	ADDRESS	34.24523	-118.36321	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 92  (SOLARCITY STANDARD SC325) MODULES, 92  (SOLAREDGE P400) OPTIMIZERS, 1 (SE7600H-US)  INVERTER, 2 (SE10000H-US) INVERTERS,  CONNECTED TO AN EXISTING 400A MAIN SERVICE PANEL. SYSTEM SIZE IS 29.90KW DC & 36.80KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30515	17041-10000-30888	727 E PICO BLVD UNT 9	90021	14	123A211    55	5132012059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.03248	-118.25306	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURE T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30516	18041-20000-17846	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.15713	-118.43792	Tenant improvement for mall management office at mezzanine.  Plan check for energy - Building permit under 18016-10000-14096.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30517	17041-10000-10430	15520 W PARTHENIA ST	91343	6	195B145   516	2654018900	(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.22815	-118.47088	PC FOR REPLACEMENT OF LIGHTING FIXTURES FROM HID TO LED TYPE FOR ENERGY SAVING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30518	15041-10000-40141	13647 W VICTORY BLVD	91401	2	180B157   906	2329004021	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM			PC Info Complete	11/30/2015 12:00:00 AM	ADDRESS	34.18683	-118.43059	PC FOR NEW LIGHTING. NEW PARKING LOT. PC FOR T24 ENERGY ONLY.**6/13/16 This Plan is lost, new plan check under 15041-10001-40141	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30519	13041-10001-24709	153 S IRVING BLVD	90004	4	138B189  1185	5516004029	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.0716	-118.31855	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30520	13041-10000-24776	4691 E HUNTINGTON DR NORTH	90032	14	142-5A231  12	5213012042	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.08641	-118.18445	TITLE 24 PLAN CHECK ONLY. REMOVING HID LIGHT FIXTURES AND INSTALLING NEW FLUORESCENT FIXTURES.  EMERGENCY LIGHTING EXISTING TO REMAIN.1685 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30521	16041-10001-28197	1933 E 113TH ST	90059	15	087A215   181	6067004010	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	33.93257	-118.23781	this is plan check for change of interconnection to main service. permits for upgrades will be pulled separately.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30522	19041-10000-37457	13050 W SATICOY ST F	91605	2	186B161   435	2303023042	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.20703	-118.41729	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30523	13041-10000-04077	19046 W ARMINTA ST	91335	3	189B121   373	2104008018	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.2137	-118.54844	PV1 ROOF MOUNTED SOLAR INSTALLATION ON SINGLE FAMILY DWELLING SINGLE STORY. USING 49 MODULES IN 4 STRINGS. DC SYSTEM SIZE IS 12.25 KW. [INVERTERS: FRONIUS # IG PLUS 10.0-1 AND FRONIUS # IG PLUS 3.0-1 |||| MODULES: TRINA SOLAR # TSM-250 PA05.08]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30524	16041-20000-01845	15715 W MARILLA ST	91343	12	201B141   320	2671005002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.24749	-118.47439	PV1.  Install 6.84 kW roof-mounted, utility-interactive PV system.  (24) SolarWorld 285 Mono modules with SolarEdge SE6000A-US transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30525	19041-20000-13000	611 N WESTERN AVE	90004	4	141B193   838	5522010019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1924.20	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Issued	04/10/2019 12:00:00 AM	ADDRESS	34.08203	-118.30929	UPGRADE 3-PHASE 4-WIRE 120/240V DELTA SYSTEM TO A BALANCED 3-PHASE 4-WIRE 120/208V SYSTEM THRU A NEW 225 KVA TRANSFORMER AND (4) 225A DISTRIBUTION PANELS. INSTALL NEW 100A TENANT SUB PANELS IN (30) KITCHENS. TENANT UPGRADES FOR (14) KITCHENS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30526	19041-10000-34084	350 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-2D-CPIO	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.76597	-118.28432	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30527	14041-20007-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/09/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	33.95713	-118.3847	3/9/2019changes to an approved set of plans.  changes noted delta 11.  changes include rerouting service entrance conductors through the building. this is plan check only. ((((CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS. SERVICE IS NOW 5000A CENTRALIZED PULL BOX AND CUSTOMER PIPE AND WIRE TO EACH SERVICE PULL UP. THIS IS RECHECKING FOR THE MODIFICATION.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30528	18041-10000-14359	10647 N ILEX AVE	91331	7	207B157   739	2620004005	R1-1, O	North Valley				1046.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Issued	04/25/2018 12:00:00 AM	ADDRESS	34.26338	-118.42104	Install New rooftop solar system, 4.81 kW DC / 3kW AC. Scope includes (1) 3kW central inverter, (13) modules with (13) P370.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30529	19041-20001-26475	1717 E 7TH ST	90021	14	124-5A215  56	5164022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Approved	08/07/2019 12:00:00 AM	ADDRESS	34.03495	-118.23573	Expedited plan check fee.(((PV3.  Install 80.3 kW DC / 66.6 kW AC roof mounted grid tied PV system.  (220) modules with 66.6 kW rated inverter and step-down transformer.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30530	13041-10000-05176	116 S AVENUE 60	90042	1	151-5A229  94	5492015021	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Expired	04/17/2015 12:00:00 AM	ADDRESS	34.11075	-118.1888	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE: 2.45KW. TOTAL MODULES: 10. [INVERTER: SOLAR EDGE. MODEL#: SOLAR EDGE SE3000A-US] [SOLAR PANEL MODULE: TRINA SOLAR. MODEL#: TSM-245 PC/PA05].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30531	15041-20000-08468	16310 W RAYMER ST	91406	6	189B137    16	2205029035	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.21777	-118.48799	Plan check for T-24 only for Cardinal Health. Total area: 783 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30532	19041-20001-18481	12561 W MILTON ST	90066	11	105B157   475	4221026021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	33.98438	-118.42027	Revisions to approved set.  Addition of fused disconnect in garage.  $0 plan check fee per State Senate Bill SB 1222 and AB 1414.  (((PV1. New 7.6 kW AC Roof Mounted Solar w/ (1) 13.5 kWh ESS. Install (1) 7.6 kW inverter, (20)  Modules with (20) P400 optimizers, (1) Energy Storage System @ 13.5KWH & (2) New 200A Load Centers. System connect t (E) 100 MSP)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30533	11041-10000-22350	540 S NORMANDIE AVE 1-66	90020	4	135B197   947	5502018025	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.06411	-118.30015	Fire alarm for a New building with over 200 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30534	11041-10000-09402	355 S GRAND AVE 24TH FL	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.05191	-118.2525	ALTERATIONS ON THE 24TH FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30535	19041-20000-30073	1535 N CURSON AVE	90046	4	147B177   795	5550006005	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.09912	-118.35514	Plan check for PV roof mounted system, PV system size: 9.57KW with 29 PV Modules and 2 inverters(5.2KW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30536	12041-20000-28160	888 S FIGUEROA ST suite 120	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Expired	12/22/2014 12:00:00 AM	ADDRESS	34.0465	-118.26225	Change to lighting in an existing restaurant.  Load is less than 400 amps and occupancy load is less than 99.  PLAN CHECK ONLY for Energy, with Emergency lighting.  suite 120.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30537	18041-20000-04009	4415 N WESTCHESTER DR	91364	3	166-5A109 121	2174013014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Issued	05/03/2018 12:00:00 AM	ADDRESS	34.15069	-118.58505	INSTALL  A NEW 19.3 KW PV SYSTEM WITH 56 AC MODULES.Fees $3.99 Due to Senate Bill 1222 for Solar Roof top	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30538	17041-10000-46124	12448 W SAYRE ST	91342	7	219B149   534	2507005009	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Issued	12/22/2017 12:00:00 AM	PIN	34.29653571	-118.4505314	New rooftop solar system, 3.64 kW AC. (13) modules with (13) microinverters, system is center-fed and plan included the engineering fault current and load calculation.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30539	12041-20000-18243	15655 W ROSCOE BLVD Bldg F	91343	12	192B141   429	2673013032	[Q]CM-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.22155	-118.47417	New roof (Building-F) mounted P.V. system with 25.92 KWdc.Note: Some modules are mounted on Buildings G (12041-20000-18246) and H (12041-20000-18249).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30540	18041-20003-08482	15000 W CORONA DEL MAR	90272	11	123B129   711	4411030007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM			PC Approved	09/04/2019 12:00:00 AM	ADDRESS	34.03145	-118.52276	supplemental plan check only for changes to approved set. decrease in circuit breaker size from 200A to 175A, reducing conduit sizes, and reducing conductor sizes. clouded changes only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30541	16041-10000-00148	816 N FAIRFAX AVE	90046	5	141B177   176	5527002034	C2-1VL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.08591	-118.36121	T-23, CHANGE OF USE FROM FROM AN (E) EDUCATIONAL/OFFICE BUILDING TO OFFICE/MUSIC RECORDING STUDIO AND ONE PARKING SPACE, SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTRACLES. TOTAL SQ. FT. 6319. *** CIRCUITS WERE PAID UNDER EXPRESS PERMIT 16041-90000-33984	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30542	14041-20001-33208	3368 S ROBERTSON BLVD	90034	5	123B169  1495	4312012018	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.02916	-118.39127	Fee for expedite only.*****Previous Description*****Commercial roof mounted PV system with Enphase Microinveter, model M215-60-2LL. total size 27 KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30543	17041-10001-32951	11844 W FOOTHILL BLVD	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Approved	06/06/2018 12:00:00 AM	ADDRESS	34.27365	-118.39446	[[6/6/18 PLANCHECK ONLY. CHANGES TO APPROVED SET. DELTA 2 CHANGES ARE CLOUDED.]]PC FOR FIRST TIME TENANT FOR RETAIL SPACE FOR SEVEN ELEVEN STORESCOPE INCLUDES NEW PANELS CIRCUITS EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 2881 SQ.FT.   B#17016-10000-26369	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30544	19041-10000-22518	3718 E YORK BLVD	90065	13	156B213   166	5459018006	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.1253	-118.23816	PV1 ROOF MOUNTED SYSTEM, SCOPE OF WORK IS 20 MODULES (Q- CELL Q PLUS 285 W) WITH OPTIMIZERS ( SEP320) AND A CENTRAL INVERTER (SE5000H-US). SYSTEM SIZE IS 5KWac/5.7KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30545	15041-10000-36763	13330 W RIVERSIDE DR	91423	4	168B157  1216	2359023022	C1-1VL, R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.15738	-118.42406	INSTALL NEW FIRE ALARM FOR A NEW 2-STORY BUILDING, AND EXISTING 2 ASTORY BUILDING WITH  81 FA DEVICES, ONE BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30546	19041-10000-25710	1875 S CENTURY PARK EAST 2nd floor	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.06115	-118.41457	T-24 PLAN CHECK FOR PARTIAL COMMONG AREA OF THE 2ND FLOOR. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1599 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30547	17041-20000-25956	920-922 S OLIVE ST	90015	14	127-5A209 175	5139004016	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Issued	07/31/2017 12:00:00 AM	ADDRESS	34.04308	-118.25854	new fire alarm panel with 5 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30548	18041-20000-14373	2123 N VESTAL AVE	90026	13	144A211    20	5420018011	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.09075	-118.25134	addition of (2) battery systems to an existing battery system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30549	14041-10001-06210	3221 N LOWRY ROAD	90027	4	153A201   246	5591001026	R1-1	Central	Hollywood	Los Feliz		1882.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	03/16/2014 12:00:00 AM	ADDRESS	34.11211	-118.28063	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800-US-ZB-U(15) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30550	15041-20000-30500	950 S FAIRFAX AVE	90036	4	132B177   461	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.05875	-118.3633	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP, 18 POWER SUPPLIES AND 441 DEVICES. DEVICES IN BLUE ARE FUTURE AND NOT PART OF THIS PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30551	12041-20000-05040	15503 W VENTURA BLVD	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.15504	-118.4723	Change of used to a restuarant.  Install 600A panel.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30552	15041-20000-34640	1096 N WESTERN AVE 1-4	90029	13	144B193   795	5536023022	C2-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.09041	-118.30895	Plan check(fire damage) in existing building(2 stories) core and shell power and energy. New 1600A Service, equipments, panels and circuits. Total area: 12,662sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30553	19041-20000-39524	16424 W DEARBORN ST	91343	12	198B137   813	2676020013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	PIN	34.23725848	-118.49044728	PV1.  Install 6.60 kW DC roof mounted grid tied PV system.  (20) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30554	19041-10000-36262	1111-1115 E 10TH ST	90021	14	123A213    33	5132005028	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	34.03263	-118.24624	SCOPE INCLUDES NEW 800A SERVICE, EQUPMENT, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 6847 SQ.FTB#19016-10000-04864 COMPLY WITH DEPARTMENT ORDER effective date 10/02/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30555	15041-10001-30112	899 S FRANCISCO ST	90017	14	129A207   155	5144023054	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.04731	-118.2643	Changes under Delta C and Delta D. Original plan checker M.Z. (((Full plan check for an 18-story hotel T.I build out. Scope includes (17) typical unit; total area is 258,716-SQ feet for T-24.Reference Application :  # 14041-10000- 35273  for core and shell with follwoing description (((Plan check for New 18 story Hotel: 350 guest rooms on 14 floors, and a 4 story podium with pool deck, meeting and ballrooms, Restaurant/retail space. 2 level of parking. Core and Shell. Service size: 1200A at 4160V. PERMIT FEES UNDER INSPECTION DUE TO PARTIAL PLAN CHECK DONE UNDER 14041-10002-35273)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30556	19041-10000-22862	355 S KINGSLEY DR	90020	10	135B193   413	5503007001	R1-1	Central	Wilshire	Wilshire Center-Koreatown		2118.03	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM			PC Info Complete	12/05/2019 12:00:00 AM	ADDRESS	34.0674	-118.30303	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES NEW 5 STORY (19 UNIT) APARTMENT W/ONE LEVEL BASEMENT PARKING AND ROOF DECK. 120/208v, 3PH, 1200 AMP SERVICE, NEW LIGHTING AND PANELTS. 7 TYPICAL UNITS. TOTAL SQ. FT. 9293 INDOOR AND 6676 OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30557	15041-20000-04853	7900 N BALBOA BLVD BLDG M	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Expired	03/22/2017 12:00:00 AM	ADDRESS	34.21347	-118.50092	PC FOR T24 ENERGY ONLY. INSTALL OF LIGHTING IN AIRCRAFT HANGERS. PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30558	18041-10000-48707	5815 W 96TH ST MSF   MSA-MSB	90045	11	093B169   162	4125023931	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/26/2018 12:00:00 AM	10/11/2019 12:00:00 AM		Issued	10/11/2019 12:00:00 AM	ADDRESS	33.94956	-118.38359	Full plan check for a new 131,493 sq/ft Maintenance and Storage Facility (MSF) for trains. This is part of the Automated People Mover (APM) project	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30559	14041-10001-07978	3150 W WILSHIRE BLVD #118	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM			PC Info Complete	07/18/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	"TENANT IMPROVEMENT FOR ""NEW"" ""JIMMY JOHN'S"" RESTAURANT INTO NEW HIGH RISE WITH RESTAURANT USES;((((((((((((((   7-5-14  changes made to approved set , title 24,  M,Z  )))))))))))))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30560	16041-10000-16336	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	FULL PC FOR POWER AND ENERGY. NEW 4000A 277/480 3 PHASE 4 WIRE SERVICE FOR A NEW 8-Story Media Production Office Building (core and shell). TOTAL AFFECTED AREA IS 154499 SQ. FT.         Fire alarm variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30561	18041-10000-07635	108-110 S ROBERTSON BLVD #108 & 110	90048	5	138B169   393	4334005003	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.07492	-118.3836	TI OF (E) RETAIL SUITE 108 AND 110 ;  NO CHANGE OF USE; REMOVE DIMISING WALL TO COMBINE RETAIL SPACESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30562	18041-20003-06702	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	33.98722	-118.47211	12-18-2018 Changes to an permitted set of plan, Changes include addtion of linear lighting fixtures and remove some lighting fixtures. Plan check only.  All Changes has been clouded as delta 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30563	15041-20001-00759	13016 W GLAMIS ST	91331	7	204B161   202	2623010010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.2569	-118.41639	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.3KW INTERCONNECTED WITH MSP.(34) ENPHASE M-215 MICROINVERTERS(34) HYUNDAI HEAVY HIS-M250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30564	19041-10000-06991	6351 W CENTURY BLVD	90045	11	093B165   163	4117034901	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	33.94563	-118.39786	LAX - AUXILIARY CURB UPGRADE PROJECT. PASSENGERS PICKUP AND DROP OFF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30565	17041-20000-38983	15716 W SATICOY ST BLDGS A-E	91406	6	186B141    96	2206014041	(T)(Q)R3-1, (T)[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			10/27/2017 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.20829	-118.47549	Addition of washer and dryer units to (42) dwelling units on a 5-building apartment complex.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30566	17041-20001-17783	8641 N TAMPA AVE	91324	12	195B117   309	2783023007	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			Reviewed by Supervisor	06/07/2017 12:00:00 AM	ADDRESS	34.22758	-118.55375	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv array with AC-coupled battery backup system.(1) 7.6kW ungrounded inverter. (26) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30567	13041-10001-26817	5900 W CENTER DR	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			11/06/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97559	-118.38853	DELTA 3 CHANGES TO PERMITTED SET OF PLANS((((((New 327-unit apartment building at Howard Hughes Center.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30568	13041-20000-32527	691 S MILL ST	90021	14	124-5A215  58	5164022001	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Expired	09/28/2016 12:00:00 AM	ADDRESS	34.03499	-118.23474	EXISTING COMMERCIAL BUILDING.  SERVICE UPGRADE OF  NEW 4000A SERVICE. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30569	19041-10000-00987	6801 S LA CIENEGA BLVD	90045	11	102B173   100	4103002019	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	05/19/2020 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	33.97696	-118.37043	FULL PLAN CHECK FOR A NEW 1-STORY RESTAURANT WITH A 1200 AMP, 120/208V, 3PH, 4W. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. TOTAL SQ. FT. 4429 INDOOR AND 31215 OUTDOOR. SERIES RATING AT 65KAIC - SEE SINGLE LINE DIAGRAM FOR COMBINATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30570	19041-20000-52450	1459 W 190TH ST	90248	15	060B193   376	7351001027	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	10/14/2020 12:00:00 AM		Permit Finaled	05/25/2021 12:00:00 AM	ADDRESS	33.85852	-118.30447	PV3.  Install 223.2 kW DC roof mounted PV system.  (558) modules with (5) 33.3 kW rated inverters.Fees $ 0.00 due to California Senate bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30571	15041-20000-32666	9001 N ZELZAH AVE	91325	12	195B129   129	2768003017	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.23392	-118.52323	"""0$ permit fees due to senate bill 1222""PV1. Instal roof mounted PV system sized 12 kW. Interconnected with main service panel.(48) Canadian Solar 255 Modules](2) Fronius Primo 6.0-1 Inverters"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30572	18041-10001-04185	1755 W CLINTON ST	90026	13	138A207   120	5404009015	RD2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2018 12:00:00 AM			PC Approved	05/09/2018 12:00:00 AM	ADDRESS	34.07293	-118.26361	SUPPLEMENTAL - CHANGES TO APPROVED SET OF PLANS - SCOPE INCLUDES ADDITION OF DISCONNECT AT INVERTER LOCATION. New PV1, rooftop solar system on SFD. System size 4kW AC/ 3.6 kW DC. (12) modules, (1) central inverter, (1) Rapid shutdown box	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30573	14041-20000-26840	13050 W SAN VICENTE BLVD 208	90049	11	129B137   501	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Issued	09/29/2014 12:00:00 AM	ADDRESS	34.0483	-118.49125	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHTING TO EXISTING POWER EQUIPMENT.  NO NEW LOADS.  788 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30574	16041-10000-08802	239 E 73RD ST	90003	9	102B205   952	6022009026	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	33.97394	-118.27043	PV1, rooftop solar installation 1.72kWac.  (8) MODULES-SE-F270      (8) MICROINVERTERS-M215-60-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30575	19041-10000-32787	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.97811	-118.39245	Full plan check for a Temp' museum located on the 2nd floor of a 2-story building. Scope includes a new 1200-Amp distribution with (1) 500kVA transformer. Service load calculation also need to be provided for justifying the main service load calculation. Total lighting area is 15,583-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30576	15041-10001-33436	4929-4931 N LANKERSHIM BLVD	91601	2	168B173    66	2353017001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM			PC Approved	10/09/2015 12:00:00 AM	ADDRESS	34.1605	-118.3723	((10-9-2015 PLAN CHECK FOR POWER. THIS IS A PLAN CHECK ONLY APPLICATION))PLAN CHECK FOR ENERGY ONLY FOR NEW RESTAURANT. PERMIT HAS BEEN PULLED UNDER APPLICATION: 15041-30000-30876. PLAN CHECK ONLY APPLCIATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30577	13041-10000-02043	3070 N SAN FERNANDO ROAD	90065	13	153A213    85	5458001905	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			PC Info Complete	01/25/2013 12:00:00 AM	PIN	34.11417491	-118.24572489	TI IN AN EXISTING COMMERCIAL BUILDING (EL POLLO LOCO) . PLAN CHECK FOR T-24 ENEGRY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30578	14041-10000-35384	3011 E PICO BLVD	90023	14	118-5A223 104	5169004001	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.01862	-118.21515	Energy plan check for removing HID and installing LED light fixture in a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30579	13041-10000-35320	2029 S CENTURY PARK EAST SUITE 1900	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI for an office suite in a highrise building.  Emergency lighting and Title 24 plan check for changes to lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30580	14041-20001-00509	9449 N BIANCA AVE	91325	12	198B129    34	2766019003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.24276	-118.5143	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30581	13041-20000-27808	4520 N VAN NUYS BLVD	91403	4	168A151   188	2265013025	C2-1VL, P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.15371	-118.4485	New outdoor lighting for an existing Grocery store.  Load is less than 400 amps.  PLAN CHECK ONLY for ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30582	13041-10000-00314	1000 N ONEONTA DR	90065	14	153A221    91	5475012030	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.11484	-118.21481	photovoltaic system for single story single family dwelling. microinverter using enphase m215-60-2ll-s22.             solar panel -  canadian solar cs6p-245m17 modules. 4.165kwpv.1 roof mounted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30583	13041-10001-29521	4929 N HASKELL AVE	91436	5	168B141    95	2261006061	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.16029	-118.47511	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30584	17041-10000-43167			11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	PIN	33.94678571	-118.40391619	PC FOR OFFICE TI converting (E) office suite to a confrence room FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 970 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES WITH ONE NEW CIRCUIT.B# 17016-10000-34135	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30585	19041-10000-07504	355 S GRAND AVE #3130	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			PC Info Complete	03/05/2019 12:00:00 AM	ADDRESS	34.05191	-118.2525	T-24 PLAN CHECK FOR A TI TO AN EXISTING OFFICE SPACE. SUITE 3130. SCOPE INCLUDES NEW 100A PANEL, LIGHTING, EQUIPMENT AND RECEPTACLES. TOTAL AFFECTED AREA IS 2925 SQ.FTB# 18016-20000-29181	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30586	11041-20000-24070	915 W WILSHIRE BLVD 960	90017	9	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	09/12/2012 12:00:00 AM	ADDRESS	34.05069	-118.2599	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING  FOR TENANT IMPROVEMENT IN SUITE #960. PERMIT FOR NEW BRANCH CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30587	19041-20000-28684	24629 W STONEGATE DR	91304	12	186B089   117	2017028049	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.20924	-118.65717	PV1.  Install 4.86 kW grid tied roof mounted PV system.  (18) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30588	13041-20000-09518	9232 N KEWEN AVE	91352	6	198B165   206	2629013057	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.23744	-118.40058	PV1 ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE IS 5KW. [INVERTER: ENPHASE # M215 |||| MODULES: TRINA SOLAR # TRINA 240 W]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30589	17041-20000-34037	201 N FIGUEROA ST 1070	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for energy only. TI to office suite 1070 in high rise building. New lighting (incl. emergency) - 3,000sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30590	13041-10000-11685	701 S VERMONT AVE	90005	10	132B197   227	5094011024	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			PC Approved	05/06/2013 12:00:00 AM	ADDRESS	34.05952	-118.2918	remodel 2 ea existing tenant space to a Boba shop-701 & 703Bplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30591	18041-20000-47042	16551 W VICTORY BLVD	91406	6	180B137   725	2231010062	[Q]R4-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Apartment			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.18684	-118.49422	Plan check for the replacement of the FACP for an existing fire alarm system and the addition of (2) devices. Project site is an apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30592	15041-10000-08204	21431 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Issued	10/06/2015 12:00:00 AM	ADDRESS	34.25739	-118.59841	SERVICE UPGRADE 2000 AMPS.  RECONNECTING TO EXISTING FEEDERS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30593	18041-20000-01196	15230 W VANOWEN ST	91405	6	180B145    39	2235004009	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.19371	-118.46506	Install central station monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30594	15041-10000-42284	6861 N LANKERSHIM BLVD	91605	2	183B169   697	2321018003	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	PIN	34.19540086	-118.38817117	NEW RETAIL. PC FOR POWER AND ENERGY. DUE TO BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30595	18041-10000-32784	10341 N WOODLEY AVE	91344	12	204B137   113	2679007039	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.25922	-118.48504	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30596	19041-20000-02024	14006 W RIVERSIDE DR #243	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Issued	05/14/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only in existing space Tenate Improvement Total area: 6070 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30597	19041-10000-24603	18408 W OXNARD ST BUILDING-2	91356	3	177B125   698	2157001147	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/02/2020 12:00:00 AM		Permit Closed	02/22/2023 12:00:00 AM	ADDRESS	34.17983	-118.53357	PC (ENERGY ONLY) FOR CORE & SHELL-CHANGE OF USE FROM WAREHOUSE/OFFICE TO OFFICE. AREA OF SCOPE 9,324SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30598	17041-10000-41775	13501 W OSBORNE ST	91331	6	198B157   204	2621022014	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.24148	-118.42719	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30599	16041-10001-39040	601 W 5TH ST STE R102	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	Changes to an approved set of plans. All changes are made under delta 6. Changes include removing unit equipment from plans and utilizing existing generator to feed exit signs and emergency lights, revising floor plans and title 24. Note: Permit is paid under orginal application 16041-10000-39040	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30600	19041-20002-06866	8700 S PERSHING DR PV1	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Revisions to approved set of plans and change of scope of work.  Approval for clouded changes delta-1 only.  Work description change: PV2.  Install 23.725 kW DC / 22.68 kW AC roof mounted grid tied PV system.  (65) modules with (1) 20 kW rated inverter.  Interconnecting with MSA-1.  (((PV2.  Install 23.36 kW DC / 21.34 kW AC roof mounted grid tied PV system.  (64) modules with (1) 20 kW rated string inverter.  Interconnecting with MSA-1.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30601	17041-10000-19188	7061 W FOOTHILL BLVD PV	91042	7	202-5A201 456	2568016050	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			Re-activate Application	07/18/2017 12:00:00 AM	ADDRESS	34.24814	-118.28543	PC FOR PV SYSTEM ROOF MOUNTED COMMERCIAL BUILDING. SYSTEM IS FEED IN TARRIF, PV COMPLETELY FEED INTO UTILITY DIRECTLY. PERMIT FEES TO BE UPDATED DUE TO CHANGES IN DESIGN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30602	18041-10000-45871	5370 E ALHAMBRA AVE	90032	14	139-5A235 261	5220031009	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.07649	-118.16861	FULL PC FIRST TIME TENANT. CHANGE OF USE FROM  EXISTING MANUFACTURING BUILDING TO RESEARCH (MEDICAL RESEARCH FACILITY) AND DEVELOPMENT.  SCOPE OF WORK INCLUDE 2718 SQ-FT. 2 NEW PANELS + ONE SUB-FED PANEL. EXISTING SERVICE IS 1600A ,208/120V, 3PH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30603	17041-10000-38686	1054 N VINE ST	90038	13	144B189   743	5534022032	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.09001	-118.32643	PLAN CHECK FOR POWER AND ENERGY FOR FOR TI - CHANGE OF USE FROM LAUNDROMAT TO DENTAL CLINICNEW CONNECTED LOAD IS APPROX = 300A ON EXISTING 600A SERVICE TOTAL AFFECTED AREA = 4080 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30604	11041-20000-21813	5700 N CANOGA AVE	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM			PC Approved	10/12/2011 12:00:00 AM	ADDRESS	34.17365	-118.59715	T.I.  Expanding into existing office space to create one tenant occupied 2nd floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30605	17041-10000-14943	9620 N TOPANGA CANYON PL	91311	12	201B105   216	2746016050	(Q)MR1-1, MR1-1, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24499	-118.60521	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new LED ones. Area: 29,750 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30606	15041-10003-15836	20943 W SATICOY ST	91304	3	186B109   218	2109023003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.20845	-118.58994	CHANGES TO THE APPROVE SET OF PLAN. CHANGE OF RACK FROM KINETIC ATTACHMENT TO PRO SOLAR FASTJACK. PLAN CHECK ONLY.PV1 INSTALL 5.232 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES:SUNPOWER SPR327NE-WHT-D(1) INVERTER ABB PVI-5000-TL-OUTD-US-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30607	17041-10001-25558	438 S MAIN ST	90013	14	129A211   137	5148009013	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM			PC Approved	12/15/2017 12:00:00 AM	ADDRESS	34.04716	-118.24785	suplemental for lost set of plans.Energy plan check for a bar T.I. Scope includes new lighting and equipment. Total area is 1776 SQ ft. Note. building permit is under 2014. B# 14016-10000-23625	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30608	11041-10001-04954	525 S FLOWER ST B Level	90071	9	130-5A209 146	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.05109	-118.25696	Modification to previously approved set of plans.  Change of emergency lighting fixtures and circuiting and receptacles.  <<<<<<T.I.  NEW OFFICE SPACES FOR THE BASEMENT LEVEL OF BUILDING.  USED TO BE A RETAIL SPACE.  FULL PLAN CHECK.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30609	16041-10001-10073	5971 S MAIN ST	90003	9	105B201   542	6005015031	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.01	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	33.98545	-118.27419	PC for changes to approved set. Changes are for relocating two lights in parking, relocating two EV chargers in parking area and reducing the number of wall switches from six to two for commercial tenant units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30610	14041-20000-06413	10450 N DE SOTO AVE	91311	12	207B109   628	2706015033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Expired	04/13/2016 12:00:00 AM	ADDRESS	34.26047	-118.58835	pv1 single family dwelling. total system size 9.8kw ac using 46 microinverters. nonstandard plan. interconnection to 400A service. ensure 20ft distance from main service to subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30611	13041-10000-23014	5657 E FALLSTON ST	90042	14	157-5A227 374	5485013018	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.12386	-118.19512	PV1.  Install 2.45 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30612	11041-10000-16563	4411 W SLAUSON AVE	90043	8	108B181   695	5008015044	[Q]C1.5-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Expired	01/21/2014 12:00:00 AM	ADDRESS	33.98904	-118.35222	Verizon Wireless is installing 4 new cabinets and installing the equipment needed to power those cabinets.  All work conducted is on the first floor of the building.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30613	19041-30000-20523	857 N HAYWORTH AVE	90046	5	144B177   485	5529021047	R3-1	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			05/30/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	01/15/2022 12:00:00 AM	ADDRESS	34.08709	-118.36295	Plan check for a fire alarm system. Project site is a 4-story, 10-unit apartment building. Fire alarm system consists of (1) FACP and (73) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30614	13041-10004-32778												Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM				DELTA   AB REVISIONS TO PERMITTED SET OF PLANS:INSTALLATION OF LED SIGNS ON SIDES OF PARKING  FACILITY; TITLE 24 COMPLIANCE FORMS ADDEDFOR A UNIT SUBSTATION , CHANGE A FEEDERS TO CU ;POWER CABINETS FOR UPS NOW HAS THEIR OWN PANEBOARDSALL CHANGES ARE CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30615	11041-10001-11319	6022 W AVION DR	90045	11	090B165    36	4129028900	M2-1	West Los Angeles				9800.28	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	33.94182	-118.39269	Modification Delta 4 and Delta 5 to previously approved set of plans.  Plans were submitted and approved under 11041-10000-11319.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30616	18041-10000-05055	9850 S LAUREL ST Major-1 of 2	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Closed	11/25/2019 12:00:00 AM	ADDRESS	33.94793	-118.23082	PC FOR POWER ONLY. NEW CORE AND SHELL 1-STORY RETAIL BLDG, SCOPE OF WORK INCLUDES NEW SERVICE 208/120V, 3000AMP. T-24 SHALL BE IN A SEPARATE APPLICATION. (JORDAN DOWNS PHASE 1C, MAJOR 1&2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30617	13041-10005-26817	5900 W CENTER DR	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			10/26/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	33.97559	-118.38853	Change to approved set by changing all main feeders from Copper to Aluminum, service load calculation being   revised and some units load calculation also being updated. All changes are under delta-8 only. per M.Z(((8/10/2015CHANGE OF ENGINEER.  PLAN CHECKER TO VERIFY LETTER FOR CHANGE OF ENGINEER BEFORE FINAL APPROVAL OF PLANS.  CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 7.  CHANGES INCLUDE REVISIONS TO THE LIGHTING AND REVISIONS TO THE ENERGY CALCS.   (((New 327-unit apartment building at Howard Hughes Center.  Power and energy.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30618	13041-10000-25484	11755 W WILSHIRE BLVD	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	PIN	34.04869377	-118.46238681	permit to be pulled at EPC counter only. PC for energy. emergency on hiriseTENANT IMPROVEMENT WORK ON +/- 16,520 SQ FT OF THE TOTAL FLOOR AREA; NEW WALLS, LIGHTING, FINISHES. THE ENTIRE 11TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30619	16041-20000-36915	201 N FIGUEROA ST 15th Floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for Title 24 only. Project site is the 15th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 17,001 sq. ft.Note: Building permit has been pulled under 16016-10000-21079	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30620	13041-10000-30618	9500 N EL DORADO AVE	91352	6	198B165     4	2629006005	MR2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.24142	-118.39897	Food storage/warehouse space TI.  Installing roll-door motor, AC, and lighting fixtures.  Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30621	18041-20000-43438	6536 N GAVIOTA AVE	91406	6	180B141   506	2233017029	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.1897	-118.48128	PV1.  Install 11.52 kW DC roof mounted grid tied PV system.  (32) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30622	10041-20000-15965	11444 W OLYMPIC BLVD 5th & 11th-Floors	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	ADDRESS	34.03654	-118.44363	TI IN THE ELVATOR, LOBBY & RESTROOMS OF THE 5TH AND 11TH FLOOR.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30623	15041-20000-11875	23023 W SHERMAN WAY	91307	12	183B097     4	2021014050	QC2-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.20116	-118.62854	Plan check for power and Title-24 (energy).  Total area = 2,780 sq. ft.  T.I. to existing hospital building.  Space is currently vacant.  Building has two services.OSHPD 3 project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30624	14041-20000-02603	5548 N IRONDALE AVE	91367	3	174B109   509	2151033084	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.17153	-118.58527	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30625	10041-10000-01877	6541 W HOLLYWOOD BLVD	90028	13	148-5A187  99	5547008002	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	02/12/2010 12:00:00 AM		Permit Finaled	04/27/2010 12:00:00 AM	ADDRESS	34.10175	-118.33239	T.I. for existing restuarant.  Install general and emergency lights in indoor and outdoor areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30626	12041-10001-00821	401 S ROSSMORE AVE	90020	4	135B185   243	5505011012	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.0668	-118.32745	Modification to previously approved set of drawings.  Change to run conduit on the exterior of the house, to under the crawl space, then trench from crawl space to the garage.        <<<<<<New 12.9kw rooftop photovoltaic system for an existing single family residence.  3 inverters and 60 modules.  Conductor to be run underground in a Methane Zone.  (No methane report was provided so project shall follow Methane Standard Part V, Sec. D.2)>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30627	15041-20000-10109	1580 W 36TH ST	90018	8	120B193  1269	5041016019	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.0227	-118.30548	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (21) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30628	19041-10000-09116	5707 S 7TH AVE	90043	8	108B189  1077	5006021015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.99064	-118.32486	PC for a new PV system for a single family dwelling. system include 12 modules(canadian solar CS6U-335M), W/Optimizier (solaredge P370), central inverter (solaredge 3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30629	16041-30000-35005	5757 W CENTURY BLVD # 808-# 820	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	33.9457	-118.38274	Title 24 plan check.  T.I. to existing commecial office highrise building.  New lighting, receptacles, and one new subpanel.  Total area = 7,980 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30630	13041-20000-16033	18515 W OLDENBURG LANE	91344	12	219B125   141	2601075026	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.29447	-118.53571	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 8.5 KWDC. 34 MODULES, 1 SUBPANEL, AND MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30631	17041-10001-28218	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	changes to an approved set of plans, Note changes under clouded areas. Scope of work includes change of fixtures and circuits. Plan Check only_________________________________________FULL PC FOR POWER AND ENERGY FOR EXTERIOR PLAZA AREAS. SCOPE INCLUDES TWO NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 15399 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30632	15041-20000-02379	13790 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.30953	-118.43339	REPLACEMENT OF LAUNDRY EQUIPMENT WITH NEW. NO CHANGE IN DISTRIBUTION. THIS IS A CHANGE IN FINAL CONNECTION ONLY. PLAN CHECK FOR ALL EXISTING RACEWAYS AND EQUIPMENT. PLAN CHECK FOR NEW CONNECTED LOAD TO MAIN SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30633	14041-10000-02119	12381 W FOOTHILL BLVD	91342	7	216B165   134	2527023025	MR2-1	North Valley	Arleta - Pacoima	Foothill Trails District		1042.04	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.28446	-118.40536	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 6244 SQ FT. REPLACING TOTAL OF 8 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30634	17041-10001-39474	701 S HILL ST	90014	14	129A209   229	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	01/14/2022 12:00:00 AM	ADDRESS	34.04582	-118.25475	CHANGE TO AN APPROVED SET, CHANGE INCLUDE MODIFING SINGLE LINE DIAGRAM, CONVERTING ONE 4000-AMP SERVCIE INTO (1) 2000-AMP AND (3) 1000-AMP SERVICES. POWER AND  LIGHTING PLANS ALSO BEING MODIFIED; ALL CHANGES MARKED UNDER DELTA -9 ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30635	16041-10000-45554	10250 W SANTA MONICA BLVD # 2660	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			Corrections Issued	12/29/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""SHUHARI"" Ste. 2660.  Install new panels and its circuits, lights and receptacles. Total effected area: 723 sq.ft. ."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30636	10041-10000-18823	709 S OLIVE ST #A	90014	14	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM			PC Info Complete	11/15/2010 12:00:00 AM	ADDRESS	34.04642	-118.25602	TENANT IMPROVEMENTS IN OFFICE/STORAGE AREASPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30637	16041-10000-13870	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	FULL PC FOR A CORE AND SHELL RESTAURANT AND VALET AREA IN THE BEVERLY CENTER  WITH A NEW 5000 AMP SERVICE. REPLACEMENT OF RESTAURANT AND VALET AREA LIGHTING. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES AND SWITCHGEAR.BUILDING PERMIT # 16016-10000-01909	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30638	14041-20001-32113	12001 W IREDELL ST	91604	2	159B165    93	2376021006	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.13093	-118.39411	PV1 INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN ELECTRIC PANEL. 9.5 KW DC/8KW ACFEE EXPEDITE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30639	15041-20000-06166	18606 W CANTARA ST	91335	12	192B121   938	2103006008	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.21916	-118.53877	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (33) 170W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30640	14041-20001-14506	4300 N BECK AVE	91604	2	165B169   594	2365027014	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.14741	-118.38321	Fee for Expedite****Roof mounted PV system size 6.75KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30641	17041-10000-28918	9950 N BALBOA BLVD	91325	12	204B133   695	2685007015	A2-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.25194	-118.50219	PC FOR PV SYSTEM ROOF MOUNTED USING 3 CENTRAL INVERTERS. TOTAL OF 70 MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30642	19041-10000-43544	5825 W SANTA MONICA BLVD Bldg B	90038	13	144B189   595	5534017022	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	06/22/2022 12:00:00 AM	ADDRESS	34.09089	-118.31662	"0$ final fees per AB1414BLDG ""B"" ** ROOF TOP SOLAR PLAN CHECK FOR 22.8KWac (26.478 KW CEC AC) (29.7 KWdc) USING 90 AXITEC-AC-330P/156-72S MODULES, 90 SOLAREDGE P400 OPTIMIZERS, AND 2 SOLAREDGE SE11400H-US INVERTERS."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30643	13041-10000-04824	590 N VERMONT AVE 2nd Floor	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	UNIVERSITY CLASSROOMS & OFFICE ON 2ND FLOOR IN EXISTING 6 STORY building with additional work on 3rd floor and basement. work on electrical rooms and restrooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30644	13041-20000-26157	18320 W BLACKHAWK ST	91326	12	204B125   142	2731017014	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.25805	-118.53263	Roof mounted photovoltaic system.  3.27kw UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30645	11041-20000-04932	10250 W SANTA MONICA BLVD #H-57	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	TI - REMODEL EXISTING RETAIL. PLAN CHK IS FOR TITLE 24 ENERGY. LIGHTING ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30646	19041-20000-44373	18857 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	05/04/2022 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30647	18041-20000-19500	4119 W SANO ST	90065	1	150A221    58	5464005049	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.10682	-118.21913	Plan check for the addition of a Tesla PowerWall onto an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30648	15041-20000-19423	13622 W FOOTHILL BLVD	91342	7	222B157   155	2513006022	C2-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Issued	09/30/2015 12:00:00 AM	ADDRESS	34.30717	-118.43031	PLANCHECK FOR T24 ENERGY ONLY. OUTDOOR LIGHTING FOR JACK IN THE BOX. 23430 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30649	12041-20001-30858	5949 N VAN NUYS BLVD	91411	4	177A151   185	2244001020	C2-1VL, M1-1, P-1VL, R4P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	PIN	34.17831798	-118.44921314	"Changes from previously approved plans.  Changes include outdoor LED lighting and series rated for a panel ""HD"".  No change to indoor lighting.   All changes indicate by DETLA-8 as shown on plans.  Plan check for power and energy.*****Previous Description*****New Keys Chevrolet Dealership with Display Room - Power and energy."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30650	12041-10000-03930	1642 N LAS PALMAS AVE	90028	13	148-5A185 170	5547014018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.10104	-118.33601	Plan check power and energy for new 800A service upgrade and equipment to existing restaurant/bar.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30651	17041-20001-26375	12415 N RALSTON AVE	91342	7	219B149   618	2507006020	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.29588	-118.45099	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (60) modules, (60) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30652	15041-10000-27014	12700 W MILLENNIUM #46	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	Installation of roof-mounted solar PV, AC, system. (6) modules, (1) subpanel, total size 1.5Kw. Application is for plan check only, permit fee is paid under 15041-90000-26267.(6) sunpower modules SPR-X20-250-BLK-B-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30653	16041-20000-12347	990 W 190TH ST 1st & 6th-Floor	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	33.85813	-118.29505	Plan check for energy only. TI to 1st and 6th floors of existing high rise office building. New lighting (incl. emergency) and receptacles. 23,338sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30654	19041-20000-26775	1512 S SUNNYSIDE TER	90732	15	012B193   444	7459011002	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	33.72986	-118.30812	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM AND A BATTERY SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6.615KW DC/7.6KW AC., SCOPE OF WORK INCLUDES (21) PV MODULES WITH P320 OPTIMIZERS, A SE7600A-USS2 INVERTER, A 5KW AUTO TRANSFORMER, A 9.8KWH LG CHEM RESU 10H BATTERY, AND A 100A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30655	15041-10000-28952	1900 S AVENUE OF THE STARS STE 950	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.05979	-118.41671	Energy plan check for an office T.I located in the 9th floor of a high rise building; Scope includes new lighting and receptacles. Total area is 1645-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30656	19041-20000-27972	820 S SHERBOURNE DR	90035	5	135B173  1011	4333024030	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/17/2021 12:00:00 AM	ADDRESS	34.06237	-118.37917	Plan check for a fire alarm system for a 4-story, 6-unit apartment building. Fire alarm consists of (1) FACP and (44) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30657	16041-10000-29788	1103-1109 S BOYLE AVE	90023	14	123A219   118	5170008022		East Los Angeles				2060.50	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.03162	-118.2203	FEES ARE $0 DUE TO SENATE BILL 1222.((((PV2. NEW SOLAR SYSTEM ON AN EXISTING COMMERCIAL BUILDING'S ROOF-TOP. TOTAL SYSTEM SIZE IS 534.65KWdc / 400KWac. (1445)MODULES-SUNPRME MAXIMA-GXB-370(5)INVERTERS-DELTA ELECTRONICS M80U-122(1)800A SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30658	14041-10000-08994	5311 N MOUNT HELENA AVE	90041	14	163-5A227 107	5691006015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.14329	-118.19595	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON O 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)  TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(14) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30659	17041-20000-08521	1026 S SANTA FE AVE 1ST FLOOR	90021	14	123A217   238	5166005004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.03072	-118.2298	Plan check for energy only. Change of use from manufacturing to office - first floor of existing 3-story building. TI to entire floor. New lighting (incl. emergency). 6,090sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30660	17041-20000-01901	16907 W BIRCHER ST	91344	12	213B133   328	2610008008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.28186	-118.50022	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (30) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30661	17041-10000-45715	430 W ANAHEIM ST	90744	15	030B205   443	7416028022	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.77957	-118.2674	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30662	19041-30000-31492	9410 W SIERRA MAR PL	90069	4	147B165   488	4392003003	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Issued	10/16/2019 12:00:00 AM	ADDRESS	34.09639	-118.39493	600 AMP 120/240 1PH SERVICE SIZE. SCOPE OF WORK INCLUDES PANELS AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30663	13041-20001-32919	141 N MARTEL AVE	90036	5	138B181   645	5512011010	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.07486	-118.35123	((Expedite fees))PV1 HIGH FREQUENCY TRANSFORMER. TOTAL SYSTEM SIZE 18KW. 54 MODULES AND 3 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30664	10041-20000-08108	21300 W SHERMAN WAY #15-16	91303	3	183B105   211	2112027008	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	ADDRESS	34.20077	-118.59568	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT OF NEW DENTAL OFFICE (SUITE #15-16) . ELECTRICAL CORE & SHELL UNDER #09041-20000-15720	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30665	15041-20000-42258	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	PC FOR POWER AND ENERGY. SCOPE INCLUDES 6 NEW CHARGE STATIONS AND ONE NEW PANEL IN A PARING GARGAGE. TOTAL AREA IS 1440 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30666	12041-10000-27037	6430 W SUNSET BLVD	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.09782	-118.32979	Plan check for title 24 and emergency lights in a high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30667	12041-20000-26917	812 W 165TH PL	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	33.88061	-118.28977	Fire alarm system for two story school building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30668	10041-10000-00059	440 S VERMONT AVE	90020	13	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			01/04/2010 12:00:00 AM			PC Info Complete	01/19/2010 12:00:00 AM	ADDRESS	34.0659	-118.29143	New methane mititgation system for existing and new commercial buildings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30669	16041-10000-14755	13079 W EUSTACE ST	91331	7	213B161   227	2524009021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.2827	-118.41771	PV1 roof mounted solar system installation. (1) central inverter: 3.8 kw, (14) solar modueles.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30670	10041-20000-00329	2619 W WILSHIRE BLVD	90057	1	133-5A201  70	5141009015	C4-2	Central	Westlake	MacArthur Park	YES	2087.20	Electrical	Electrical	Commercial			01/08/2010 12:00:00 AM	06/09/2010 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.06097	-118.28196	REPLACE 2 ELEVATORS AND UPGRADE EXISTING FIRE PUMP GENERATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30671	18041-10000-20325	6505 S ESPLANADE #1	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			Reviewed by Supervisor	06/13/2018 12:00:00 AM	ADDRESS	33.96159	-118.45071	1 OF 5******PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT BUILDING. CONISIT OF 8 MODULES(#SC325) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 2.6KWdc.SCOPE INCLUDES NEW LOAD CENTER (125A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30672	19041-20000-11124	5031 N FAIR AVE	91601	2	171B173  1095	2353011037	R4-1	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	10/17/2020 12:00:00 AM	ADDRESS	34.1617	-118.37478	Install roof mounted pv system sized 166.5KW AC CEC, 182KW DC interconnected with MSP 1200A.(500) astrohalo modules 365Watts(5) solaredge 33.3KW invertersFees $0.00 due to Caifornia Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30673	19041-20001-02755	2733 N AQUA VERDE CIR	90077	5	156B141    91	4378031022	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	34.12201	-118.47257	Expedite per applicant request Plan check for PV roof mounted system, system size: 16.95KW DC, 15.2KW AC,  with 42 PV Modules and 2 inverter(7.6KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30674	19041-10000-02958	150 W CENTER WAY APM East-Station	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Issued	01/09/2020 12:00:00 AM	ADDRESS	33.94448	-118.40007	FULL PLAN CHECK FOR POWER AND ENERGY FOR LAX SCOPE OF WORK INCLUDES NEW 1200AMPS SERVICE,480/277 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 73790 SQFT NEW LD# 18010-10001-04778	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30675	11041-20000-20810	5711 N SEPULVEDA BLVD	91411	4	174B145   168	2243002021	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.17435	-118.4665	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT ON EXISTING RETAIL (TARGET) FITTING ROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30676	14041-20001-06898	16427 W SAN JOSE ST	91344	12	207B137   772	2679005034	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	PIN	34.26127747	-118.49014442	(((expedite fees)))pv1 single family dwelling. total system size 3.8kw ac using transformerless inverter. using power optimizers. nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30677	17041-20001-35804	11142 N CHRISTY AVE	91342	7	210B177   256	2528029027	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	34.27206	-118.35904	expeditepv1install roof mounted pv system sized 3.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30678	16041-10000-38462	7525 N QUIMBY AVE	91307	12	186B093   246	2021001010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Issued	10/31/2016 12:00:00 AM	ADDRESS	34.20675	-118.63129	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.16KWdc / 5.280KWac.(22)MODULES-CANADIAN SOLAR CS6K-280M(22)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30679	18041-10000-23287	12537 W SHERMAN WAY	91605	2	183B161    19	2324003038	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Issued	06/22/2018 12:00:00 AM	ADDRESS	34.20136	-118.40638	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30680	19041-10000-39109	520 E MANCHESTER AVE UNIT 2	90003	9	097-5A207 324	6041019003	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	04/07/2020 12:00:00 AM	ADDRESS	33.95996	-118.26583	T-24 PLAN CHECK FOR TI TO A REATIL STORE. LOAD UNDER 400A. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1229 SQ.FT. ELECTRICAL SERVICE AND PANELS ARE APPROVED UNDER 19041-10000-25012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30681	16041-10000-43328	7101 N VANSCOY AVE	91605	2	183B161   246	2324033017	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.19937	-118.40648	PV1 roof mounted solar system installation to a single family home. Installing central inverter rated at 7.6 KW, 30 modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30682	19041-20000-47470	701 S COURTLAND ST	90291	11	111B145   120	4243027007	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.00371	-118.46181	PV1 NEW ROOFTOP SOLAR SYSTEM, SYSTEM SIZE IS 6.5KWdc/ 6.3KWac. SCOPE OF WORK IS 20 MODULES (VBHN325) WITH MICROINVERTERS (IQ7X-96-2), LEADING TO A COMBINER BOX, TERMINATING IN AN EXISTING 200A MAIN SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30683	12041-10000-27844	10782 W WEYBURN AVE	90024	5	132B153    41	4360004022	R1-1-O	West Los Angeles	Westwood	Westwood		2652.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	ADDRESS	34.06183	-118.43954	PV1 ROOF MOUNTED SOLAR INSTALLATION 3.43 KW. ENPHASE 215 MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30684	19041-10000-38388	1745 E 7TH ST	90021	14	124-5A215  58	5164022012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Issued	11/05/2019 12:00:00 AM	ADDRESS	34.0349	-118.23475	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 5305 SQFT. NOTE THE 600A DISTRIBUTION BOARD HAS BEEN PULLED UNDER 19041-20000-29520. ALL OTHER EQUIPMENT IS EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30685	19041-10000-17876	5231 W IMPERIAL HWY	90045	11	087B173   728	4129038010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	33.93109	-118.37105	"FULL PLAN CHECK FOR A TENANT IMPROVEMENT TO EXISTING AUTO PAINTING BUIDLING IN PREPARATION FOR NEW TENANT ""LYFT""CAR GARAGE WITH FUTURE PAINTBOOTH AND PREPDECK TO BE PERMITED UNDER A SEPERATE PERMIT. (HAZARDOUS LOCATION)SCOPE INCLUDES NEW 600A 208/120V SERVICE, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 6972 SQ.FT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30686	18041-20000-43698	1000 W WILSHIRE BLVD ste 1860	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.05085	-118.26078	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30687	14041-10000-22022	3951 W AVENUE 43	90041	14	157-5A219 241	5473022016	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.12538	-118.22376	Installation of roof mounted solar PV array.  Total system size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30688	14041-20000-15210	100-120 N SANTA FE AVE	90012	14	129A217    74	5173013016	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.04867	-118.23239	NEW 1200 AMP 120/208 VOLTS 3PHASE 4-WIRE SERVICE PLUS FOUR 200AMP PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30689	19041-10000-32989	8219 S VERMONT AVE	90044	8	099B197  1441	6033022005	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	33.96391	-118.29204	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30690	18041-10000-31866	229 S VERMONT AVE	90004	10	135B197   126	5518030022	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2113.20	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.06955	-118.29188	TI IN AN EXISTING COMMERCIAL AREA.T-24 ENERGY ONLY. BLDG PERMIT: 18016-70000-24058REPAIR OF FIRE DAMAGED COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30691	19041-20000-16115	20748 W BEECH CIR #312-pv1	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	11/23/2019 12:00:00 AM	ADDRESS	34.29383	-118.5855	TWO STORY SFD-CONDO WITH ATTACH 2 CAR GARAGE (STANDARD PLAN # 646 _ PLAN 1C)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30692	18041-10000-00491	19133 W PARTHENIA ST	91324	12	195B121   337	2784003054	MR2-1VL, P-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.22837	-118.55015	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30693	19041-10001-40757	13361 N GLENOAKS BLVD	91342	7	225B145   449	2501022078	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.3146	-118.45921	Expedite per applicant request.(((Plan check for a PV2 53.3KW AC / 54.7KW DC roofmounted system with (1) load center, (2) inverters, (152) modules and (76) optimizer interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30694	10041-20000-18362	458 S ROBERTSON BLVD	90048	5	138B169   861	4334003042	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	10/12/2010 12:00:00 AM	ADDRESS	34.0705	-118.38361	T.I. to existing building for a tea retail area.  Install branch circuits, general/emergency lighting.  EPC for power and energy.Note: Some circuits under a separate permit 10041-90000-17522.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30695	14041-10000-14569	6865 N VINELAND AVE	91605	2	183B173   191	2319005028	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.19587	-118.37056	T24, remove hid light fiztures and replace with new fluorescent. Total area 9333 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30696	16041-20000-37480	19230 W HATTERAS ST	91356	3	174B117   125	2156005002	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	07/01/2017 12:00:00 AM	ADDRESS	34.17566	-118.55285	"""0$ permit fees due to senate bill 1222 ""pv1install roof mounted pv system sized 13.8kw interconnected with msp."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30697	19041-20000-47589	2100 S NARCISUS CT	90291	11	108B145  1802	4237003030	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	33.98894	-118.46001	INSTALL (5) NEW FIRE SPRINKLER MONITORING DEVICES AND (1) CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30698	16041-10001-11803	5918 N FIGUEROA ST	90042	1	151-5A229 114	5492015028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.11065	-118.19026	Supplemental PC for T24 only for changes in lighting. Addition of electric oven.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30699	11041-10003-15257	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	PIN	33.94363002	-118.42513364	Delta 7 Changes to a previously approved set of plans.  T.I.  Federal Express Hangar in an unclassified area.  Relocating panels, transformer, and lighting.  New circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30700	19041-10000-45807	1901 S IMPERIAL ST	90021	14	120A217    80	5167011039	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.02321	-118.23137	REMOVE HID FIXTURES AND REPLACE WITH LED FIXTURES- T/24 ONLY. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30701	19041-20000-51317	18800 W WILLOWTREE LANE	91326	12	207B121   581	2728029057	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.26272	-118.5431	PV1.  Install 16.1 kW roof mounted PV system.  (46) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30702	10041-20000-21179	1320 N WILTON PL	90028	13	147A193   224	5545020022	[T][Q]CM-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	12/13/2010 12:00:00 AM	ADDRESS	34.09553	-118.31341	Plan check T24 Energy general/emergency lighting for office TI 2-story	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30703	13041-10000-34793	1656 N ORANGE DR	90028	13	147B181   268	5548006010	PB-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.10076	-118.34127	T24 PART 6 ENERGY FOR PARKING STRUCTURE; SCOPE OF WORK IS FOR REMOVING EXISTING LIGHTINGS WITH NEW FIXTURES FOR GROUND,SECOND,AND 3RD FLOOR. PROJECTED AREA IN SCOPE OF WORK IS APPROX. 70, 203 SQ FT AREA. EXISTING PANELS 'A' & 'B' . DESIGN-BUILD PLAN.BUILDING PERMIT # : 13016-10000-18921	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30704	14041-10000-35502	426 W 4TH ST	90013	14	130-5A211 100	5149027901	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.05069	-118.25137	Remove HID fixtures and replace with LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30705	18041-10000-18629	1118 N MCCADDEN PL	90038	4	144B185  1372	5532021030	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM			Reviewed by Supervisor	06/27/2018 12:00:00 AM	ADDRESS	34.09129	-118.33733	PC FOR NEW FA IN NEW LOW RISE MIXED USED RES. TOTAL 4 FLOORS WITH 1 PARKING FLOOR. SCOPE INCLUDES 10 PANELS AND 565 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30706	12041-10000-31131	6716 W 87TH ST	90045	11	096B161   788	4122020006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	12/31/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	33.95845	-118.40743	PV1 2 STORY HOUSE 17 MODULES [MODULE: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY {M215-60-2LL-S22}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30707	15041-10000-29675	6438 E YORK BLVD	90042	14	153A233   227	5492036008	[Q]C4-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.1138	-118.18036	NEW FIRE ALARM SYSTEM TO AN (E) COMMERCIAL BUILDING. 24 FIRE DEVICES, 1 FIRE ALARM PANEL AND 2 COMMUNICATION PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30708	12041-10002-22751	1100 S GLENDON AVE #900	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM			PC Approved	10/11/2012 12:00:00 AM	ADDRESS	34.06074	-118.44418	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR SUITE # 900. EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30709	12041-10001-13607	9144 N DEERING AVE	91311	12	198B105   160	2746010031	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	ADDRESS	34.237	-118.59594	Modification to previously approved set of drawings.            Plan check for new installation of new sprinkler monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30710	15041-20000-06792	300 S SANTA FE AVE #X	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	Plan check for T-24 only. Total area: 1097 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30711	16041-10001-30983	20248 W WYANDOTTE ST	91306	3	186B113   827	2114018215	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM			PC Approved	07/10/2017 12:00:00 AM	ADDRESS	34.20258	-118.57475	Supplemental PC for new meter socket between inverter disconnect and main panel.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30712	15041-20000-31988	555 S FLOWER ST 18TH FLR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE AND CONFERENCE ROOM. 18TH FLOOR.  778 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30713	19041-10000-43415	3210 W ADAMS BLVD	90018	10	123B189   715	5052015011	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.0324	-118.31924	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30714	19041-20000-25907	22817 W VENTURA BLVD	91364	3	171B097   401	2042017035	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.166	-118.62402	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30715	12041-20000-29743	8900 N DE SOTO AVE	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			Corrections Issued	12/10/2012 12:00:00 AM	ADDRESS	34.23162	-118.58832	New industrial manufacturing building (Foam Booth).  NOT A HAZARDOUS/CLASSIFIED AREA PER APPLICANT.  Load is less than 225 amps per applicant.  PLAN CHECK ONLY for Energy, NO Emergency lighting is part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30716	18041-10000-16900	13750 W ROSCOE BLVD	91402	6	192B153   772	2213016003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.22148	-118.43301	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING RESTAURANT - SCOPE INCLUDES REPLACING EXISTING FIXTURES TO NEW LED FIXTURES - TOTAL AFFECTED AREA = 1055 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30717	18041-10002-02129	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	33.94248	-118.40461	DELTA 3 CHANGES TO AN APPROVED SET. CIRCUIT MODIFICATION AND LOAD UPDATES ON PANEL 1LB22. 2 NEW CIRCUITS ADDEDPLAN CHECK PER APPLICANT REQUEST. Original Scope: (PC for power and energy for terminal 5 of LAX. Scope includes adding new panels, lights, receptacels, equipment to kiosk/ticketing, offices, common areas and outdoor.Total area is 29666sqft. B# 17016-10000-33718Tenant Improvement to LAX Terminal 5 to include (1) installation of new storefront glazing system, (2) new public restrooms, (3) new AA and OAL offices on Arrival Level, (4) linear ticket counters at Departure Level, (5) new medical offices on Mezzanine Level, and (6) alteration and addition to existing structural.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30718	11041-10006-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	33.94386	-118.4047	REVISION MADE TO PREVIOUSLY APPROVED SETS OF PLANS. THESE PLANS REFLECT CHANGES  OUTLINED  IN BULLETIN 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30719	14041-10001-05925	23441 S BATEY AVE	90710	15	042B197    85	7438013034	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	33.8112	-118.29942	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON-STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 5.39 KW DC.(22) TRINA SOLAR TSM-245(22)  ENPHASE M215 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30720	17041-20000-36487	1200 W 7TH ST ste 460	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.05136	-118.26616	ti to an existing commercial building.  adding new lights new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30721	13041-20000-27817	10605 N BALBOA BLVD #240	91344	12	207B133   738	2695008026	(Q)CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.26259	-118.50249	TI for an medical office.  Change to lighting and loads.  Full Plan check.    NOT STATE LICENSED, NOT CHECKED FOR OSHPD3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30722	14041-10001-02689	12695 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.97727	-118.41529	Energy plan check for outdoor lighting at partical # 5B per inspector request. total area is 5743 -SQ feet ; permit fee is paid under permit # 14041-10000-02689.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30723	19041-10000-41716	8002 N HOLLYWOOD WAY	91352	2	189B181   193	2403024005	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.21628	-118.34486	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 11.52KVA PV1 SYSTEM CONSISTING OF 36 AC MODULES(SUNPOWER X22-360-D-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30724	17041-20002-09226	12601 W PIERCE ST 1, 2, 12	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	12-19-2018 Changes to an approved set of plan, Changes include addtion of performance meter. All changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30725	15041-10000-07326	5900 W CENTER DR 1-327	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Public Safety Only			03/16/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	33.97559	-118.38853	NEW FIRE WARNING SYSTEM FOR 6-STORY APARTMENT BUILDING WITH 2 FLOORS SUBTERRANEAN PARKING.  1027 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30726	16041-10000-41138	12400 W WILSHIRE BLVD 13th floor	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.04157	-118.47031	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING OFFICE SPACE ON THE 13TH FLOOR OF A HIGH RISE BUILDING. SCOPE INCLUDES A NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 13452 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30727	13041-20000-06267	2100 W WASHINGTON BLVD	90018	10	126B193   938	5074033016	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2215.00	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.03975	-118.30604	Plan check for power and energy. Golden State Laundry Systems. Commercial Low-rise. New service and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30728	18041-10001-01272	2015 S GREENFIELD AVE	90025	5	126B153   250	4323015022	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.0441	-118.43749	expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30729	10041-30000-04871	617 W 7TH ST #204	90017	9	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	04/07/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.04779	-118.2571	Plan check T-24 energy TI in Suite #204.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30730	10041-10000-21916	310 S ROBERTSON BLVD	90048	5	138B169   610	4334011034	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM			PC Approved	11/02/2010 12:00:00 AM	ADDRESS	34.07318	-118.38361	TENANT IMPROVEMENT TO EXISTING RESTURANT; NEW FINISHES, EQUIPMENT AND FURNITURE FOR DINING ROOM & KITCHEN; NEW UNCOVERED OUTDOOR DINNING AREA; INCLUDES NEW PARTITIONING AND IMPROVEMENTS TO RESTROOMS. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30731	16041-10001-20320			12	195B117   109	2783025049	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM	PIN	34.23022606	-118.5551012	Supplemetal plan check for TI24 for approved set under 16041-10000-20320. Changing lighting fixtures from LED lights to LED down lights. Alterations are greater than 10%. All changes under Delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30732	16041-10000-06501	727 N WILCOX AVE	90038	4	141B185   493	5533035009	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			02/24/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.08421	-118.33129	NEW FOUR STORY TYPE VA TWENTY UNIT APARTMENT BUILDING OVER ONE LEVEL OF TYPE IA SUBTERRANEAN PARKING GARAGE. NEW 800 AMP SERVICE WITH 2 CAR CHARGERS. LOCATED IN A METHANE ZONE. TOTAL SQ. FT. 20355.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30733	16041-10000-44571	8846 N SEPULVEDA BLVD	91343	6	195B145   266	2654011023	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.23126	-118.46726	PC FOR ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 38,000 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30734	10041-20000-11448	17717 W VENTURA BLVD	91316	5	171B129   313	2162013011	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM			PC Approved	06/16/2010 12:00:00 AM	ADDRESS	34.16283	-118.51916	Installing exhuast fan for restroom. Inspector requested plan check. This plan check was revision to part of existing approved set under appl # 09041-20000-22630.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30735	17041-10000-45094	5999 W CENTER DR	90045	11	102B169   959	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM			PC Approved	12/15/2017 12:00:00 AM	ADDRESS	33.9761	-118.38876	Plan check for Title 24 only in existing space office T.I. Total area: 1,167 sq ft. B#17016-10000-36435	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30736	17041-10000-32560	3825 S MCLAUGHLIN AVE	90066	11	114B157   989	4214016035	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.00775	-118.42421	PC for T24 only for replacement of existing fixtures with LED fixtures. Total of 4750sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30737	10041-10000-05690	3601 S TROUSDALE PKWY	90089	8	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	07/29/2011 12:00:00 AM	ADDRESS	34.02017	-118.28558	T-24 and emergency lighting in corridors and rooms on various floors of athe building.  Less than 400 amperes of load added.  Called phase 1 on the plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30738	07041-10002-27323	2321 W 10TH ST 1-27	90006		130-5A201  37	5136004014	R4-1		Westlake	MacArthur			Electrical	Electrical	Apartment			08/03/2010 12:00:00 AM			PC Approved	10/15/2010 12:00:00 AM	ADDRESS	34.05327	-118.28254	New 27 unit apartment with 2 subterranian parking and 4 levels above grade (6 typical).  New service 1200amp, 120/240v, 1ph, 3w.  Plan check for power and energy.   Lost Approved Plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30739	12041-20000-11545	9870 N SAN FERNANDO ROAD	91331	7	201B165    77	2537015042	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.25001	-118.40419	New industrial building with new 3000A serivce.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30740	14041-10001-08051	412 N FAIRFAX AVE	90036	5	141B177  1435	5527030018	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.07866	-118.36128	Plan check only. Fees for loads on panels B and D will be on original application under inspection fees. 1ST TIME TENANT  pizza store (Mr. Pizza). CHANGES TO APPROVED TO REFLECT CHANGES IN CORE/SHELL (panels installed under core/shell plans 14041-10-07618) . EPC is for power only. Energy was checked in original application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30741	14041-10000-16357	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Apartment			06/18/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	PLANCHECK FOR POWER AND ENERGY.   New 4-story, 338 unit apartment building.  10 TYPICAL UNITS. [[[FEES ARE BASED OFF APPLICANT, PLANCHECKER TO VERIFY FEES. FEES  FOR T24 (56,000SQFT), SMOKE DETECTORS (338), PANELBOARDS(SECTIONS) , AND OTHERS NOT INCLUDED DUE TO PRE CUT CHECK ]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30742	17041-10000-19450	1441 E WASHINGTON BLVD	90021	14	120A213   241	5129007026	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	34.02256	-118.24669	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30743	12041-10000-18733	3500 E MANITOU AVE	90031	1	138A225   158	5211007020	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.0719	-118.20374	PLAN CHECK ONLY FOR T24 ENERGY OUTDOOR LIGHTING, PARKING LOT FOR EXISTING NURSING HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30744	10041-10002-21556	5764 N CHICOPEE AVE	91316	5	174B129   227	2254020020	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.17592	-118.51212	INSTALL 11.6KW ROOF MOUNTED PHOTOVOLTAIC ARRAY FOR A SINGLE FAMILY RESIDENCE.  58 MODULES, 2 INVERTERS  <<<<<<<<PROJECT IS INSTALLED AND PERMITTED, PLAN CHECK ONLY, FOR POWER>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30745	16041-10000-12629	1788 S LA CIENEGA BLVD	90035	10	126B173   133	5066006011	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.04498	-118.37655	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO AUTO GLASS REPAIR SHOP. TI TO AN EXISTING COMMERCIAL BUILDING (SAFELITE AUTO GLASS). SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 4309 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30746	11041-20001-08184	2029 S CENTURY PARK EAST #4100	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			Corrections Issued	08/14/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to existing high rise building of 41st floor.  Plan check for power and energy.revision only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30747	19041-10000-00846	2535 W TEMPLE ST	90026	13	138A203   222	5157003007	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1958.02	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.07262	-118.27462	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE SCOPE INCLUDES 3700 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30748	16041-20000-24632	2415 N GREEN VIEW PL	90046	4	153B169   248	5564033020	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Expired	09/02/2023 12:00:00 AM	ADDRESS	34.11635	-118.38911	Plan check for PV battery back up system in Single Family Dwelling 4kW battery connected to existing PV system. Note: Existing PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30749	17041-10000-36916	3500 S OVERLAND AVE	90034	5	120B161   718	4314011048	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			No Progress	10/19/2017 12:00:00 AM	ADDRESS	34.02469	-118.41134	Plan check for Title 24 only in existing restaurant T.I. existing panel with new lighting. Total area: 1197 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30750	18041-20000-29170	10768 N WHEATLAND AVE	91040	7	207B177    52	2528032013	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.26513	-118.35642	Plan check for a PV1 roof-mounted PV system. System size is 12.25 kWdc and consists of (1) 11.4 kWac rated inverter and (35) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30751	15041-20000-34311	8863 N NORRIS AVE	91352	6	195B173   310	2408025018	[Q]M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.23026	-118.37403	TI, adding new light fixtures to an existing single story catering build. All electrical equipments are existing.PC for Energy only, total area: 10,380 sq. ft (indoor and outdoor parking area).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30752	11041-20000-09715	8850 N TAMPA AVE 102-103	91324	12	195B117   410	2784003072	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.23108	-118.55333	T.I. to a restuarant.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30753	10041-10000-06292	6541 W HOLLYWOOD BLVD 107,108	90028	13	148-5A187  99	5547008002	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM	04/15/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.10175	-118.33239	T-24 and emergency lighting plan check for remodeled bar are of restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30754	13041-10000-22674	4301 W 3RD ST	90004	10	135B193   200	5517007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	PIN	34.06916769	-118.30825671	FA FOR ANDERSON MUNBER YMCA:MAIN AND SUB BUILDING. (129 devices , 1 panel, 3 power supplies and 1 annunciator).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30755	17041-20000-23678	6535 N TONY AVE	91307	12	180B089   530	2033007010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.18938	-118.64503	INSTALLATION OF BATTERY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30756	10041-20000-00261	1555 N CAHUENGA BLVD	90028	13	148-5A187 323	5546013028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM			PC Approved	01/07/2010 12:00:00 AM	ADDRESS	34.09962	-118.32969	Revision to PCIS #09041-20000-22124 (Tenant improvement and change remaining portion of building from Retail Use to Barber Shop. Title 24 and emergency lighting only.) Changed lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30757	14041-20000-10122	14605 W HIAWATHA ST	91345	7	207B149   874	2648013003	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.26015	-118.45065	PV1.Roof mounted PV system with Optimizer and transformerless inverters.  System size 6.75KW.  Interconnect with main panel, (1) SolarEdge #SE6000A-US-ZB-U    transformerless inverter(27) Canadian Solar #CS6P-250PX   pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30758	12041-20000-29679	8549 N REMICK AVE	91352	6	192B165   148	2634040005	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.22591	-118.4004	PV-1. MIcroinverter standard plan. 6.28kW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30759	14041-10000-04338	3633 S LENAWEE AVE SUITE 100	90016	10	117B173   620	4204008060	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.0205	-118.37599	TI for a 4,891 s.f. space in a commercial office space in a 2-story building.  Plan check for Title 24 for new lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30760	17041-10000-19331	6733 S SEPULVEDA BLVD	90045	11	102B165   108	4110001034	C4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Apartment			04/10/2018 12:00:00 AM	10/14/2020 12:00:00 AM		Issued	10/14/2020 12:00:00 AM	ADDRESS	33.9788	-118.39444	FULL PC FOR POWER AND ENERGY. NEW 176 ((((180 per plan))))UNIT APARTMENT BUILDING 5 STORY OVER 2 STORY PARKING GARAGE AND BASEMENT. SCOPE INCLUDES A NEW 4000A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. B#17010-10000-00045	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30761	17041-20000-29941	8862 W PICO BLVD	90035	5	132B169   921	4305014900	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Apartment			08/22/2017 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.05475	-118.38522	New 6 story apartment building with 2000 A 208Y/120V service.  Plan check for power and energy.Building application submitted under 17010-10000-01302	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30762	13041-10000-05251	5750 W WILSHIRE BLVD 6TH FL	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			PC Approved	02/28/2013 12:00:00 AM	ADDRESS	34.06227	-118.3542	revisions to offices on the 6th fl-new - new panels;circuits and lightingPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTPERMIT TO BE OBTAINED AT ELECTRICAL COUNTER13041-10000-05251	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30763	14041-10001-22825	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Closed	08/02/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	(((4/15/2015- Changes made to approved set. adding 12 devices.)))NEW FIRE ALARM INSTALLATION. 1116 FIRE ALARM DEVICES AND 1 CONTROL  PANEL.  Located at the (E) TBIT core of LAX. Limited to upgrades of the new TBIT renovation area and is to include: New digital audio amplifier (EST3) to be tied into the fire alarm system network to support the new initiating and audio devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30764	12041-10000-17490	5510 S LINCOLN BLVD 2ND FLR	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	33.97299	-118.43051	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR 2ND FLOOR OFFICE TI OF EXISTING 4-STORY OFFICE BUILDING. PERMIT FOR EQUIPMENT, NEW AND RELOCATE BRANCH CIRCUITS. LESS THAN 400A LOAD INSTALLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30765	14041-10001-12209	2700 S FIGUEROA ST #103	90007	9	121-5A203  98	5123018033	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.02708	-118.27647	((8/19/2014 - Changes to approved set.  Removal of LED from lighting plan.))Master permit work description:  permit to be pulled at EPC counter only.plan check for energy only.  5 stories. emergency lights installed. lightsBLDG#14016-10-08784: INTERIOR TENANT IMPROVEMENT FOR RESTAURANT; NEW NON BEARING PARTITIONS, COUNTER, SEATING, FIXTURES, AND FREEZER/COOLERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30766	19041-10000-05802	11766 W WILSHIRE BLVD 845	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.04804	-118.46227	TI 24 PC ONLY FOR NEW LIGHTING AND RECEPTACLES FOR A SPEC SUITE IN EXISTING HIGH RISE COMMERCIAL BUILDING. TOTAL SQUARE FOOTAGE = 2344 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30767	13041-10001-06157	3000 S HOOVER ST	90007	9	121-5A201 144	5123005031	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM			PC Approved	04/08/2015 12:00:00 AM	ADDRESS	34.02712	-118.28376	revisions to approved set of plansMinor changes to approved set of plansPLAN CHECK FOR POWER AND ENERGY FOR A NEW FIRE STATION #15. NEW 1000A SERVICE. INDOOR SQRFT: 15944 OUTDOOR SQRFT: 26617.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30768	15041-10000-07068	8124 W 3RD ST	90048	5	138B173   960	5511029032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.0721	-118.36676	600 AMP SERVICE UPGRADE TO AN EXISTING 2 STORY COMMERCIAL BUILDING. EQUIPMENT LOCATED OUTDOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30769	18041-20000-05771	1415 S REEVES ST	90035	5	132A167   299	4306002010	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			02/15/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.0547	-118.39672	New 25-unit 4-story apartment building.  2000 208Y/120V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30770	17041-10000-03093	601 W 5TH ST	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	T-24, PC FOR ENERGY ONLY. CONVERSION OF THIRD FLOOR ROOF TO EXTERIOR TERRACE. SCOPE INCLUDES ADDING NEW EXTERIOR LIGHTING FOR THIRD FLOOR. TOTAL AFFECTED AREA IS 1346 SQ. FT. B#16016-10000-30659	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30771	12041-10001-15307	4700 S INGLEWOOD BLVD	90230	11	108B161   213	4218008012	(Q)C2-1, C2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	33.99346	-118.41537	EXPAND MARKET INTO ADJACENT TENANT SPACE;ADD CU UNITS ON ROOF AND INSTALL WALK-IN COOLERPLAN CHK IS FOR TITLE 24((((((((((INSTALLING NEW PANELS, TRANSFORMER, AND NEW CIRCUITS FOR EMERGENCY LIGHTS AND RECEPTACLES.  TO INCLUDE ELECTRICAL FOR HVAC UNITS. (FIELD INSPECTOR TO VERIFY THAT TITLE 24 IS REQUIRED)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30772	16041-20000-17472	7408 N OAKDALE AVE	91306	3	186B113   558	2115012002	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Expired	06/20/2018 12:00:00 AM	ADDRESS	34.20499	-118.56694	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (19) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30773	14041-20001-24914	7014 S HOOVER ST UNIT 6	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 6.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30774	13041-10000-06650	2030 S WESTGATE AVE	90025	11	123B149   349	4262033021	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Info Complete	05/29/2013 12:00:00 AM	ADDRESS	34.03465	-118.45236	(((PREVIOUSLY APPROVED PLANS (BY FRANCIS), HOWEVER PLAN CHECK HAS EXPIRED. APPLICATION COPIED FROM: 09041-10000-16359.)))) Plan check for new service and new switchboard to feed existing distribution panels in commercial/industrial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30775	17041-10001-29217	10900 N YOLANDA AVE	91326	12	210B121   710	2717013023	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM			PC Info Complete	10/19/2017 12:00:00 AM	ADDRESS	34.26861	-118.54081	CHANGES TO APPROVED SET PER INSPECTION. SCOPE INCLUDES RELOCATION OF INVERTER AND AC DICSONNECT TO REFLECT FIELD INSTALLATION. THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER MASTER.PLAN CHECK FOR ROOF MOUNTED SOLAR SYSTEM ON SLD. CENTRAL INVERTER SYSTEM RATED AT 5.0 KW ACSCOPE INCLUDES 26 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30776	10041-10001-16395	8732 S READING AVE #1-11	90045	11	096B169   627	4125016012	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	33.95901	-118.3814	Plan check for revision to approved plans. Revision to include new water heater branch ckts, BBQ plug, unit layout (additional bathroom), T24 Energy calculation, and 30HP elevator..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30777	19041-10000-40886	925 N NORMAN PL	90049	11	138B141    19	4429011032	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	02/15/2020 12:00:00 AM	ADDRESS	34.07812	-118.47946	[E-PLAN]. inspection zero fee due to AB1414 PV1 NEW ROOFTOP SOLAR SYSTEM WITH BATTERY BACKUP. SYSTEM CONSIST OF 60 MODULES ( PANASONIC 330), WITH 60 MICROINVERTERS (ENPHASE IQ7X-96) AND 4 TESLA POWERWALLS . SYSTEM SIZE IS 19.8KW DC AND 19.2 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30778	14041-20001-06847	5809 N MELVIN AVE	91356	3	174B117    77	2153024035	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.17627	-118.56022	(((expedite fees)))PV1 TRANSFORMERLESS SYSTEM. 38 MODULES AND 2 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30779	18041-10000-01315	17331 W TRAMONTO DR Bldg # 7	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 7 (CAMPUS STYLE)SCOPE INCLUDES 53  DEVICES AND 1 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE. B# 15010-10000-03647BUILDING 7 (PLAN B1)  4 UNITS TYPE IIA 4 STORY  APARTMENT BUILDING  WITH ATTACHED  TYPE IB GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30780	15041-20000-27763	7529 N JOLENE CT	91605	2	186B165   306	2307023***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.20724	-118.40134	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel. (18) Kyocera KU265 Modules (1) ABB PVI-5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30781	16041-20000-42225	444 S FLOWER ST #2320	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is a suite within an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,067 sq. ft.Note: Building application has been generated under 16016-10000-27389	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30782	19041-20000-24900	979 N BEL-AIR ROAD	90077	5	144B153   942	4370023040	RE20-1-H-HCR		Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	34.09167	-118.44254	Plan check for power only Interior Remodeling Single Family Dwelling 800A Service 120/208 Volts 3 Phase 4 W with back up generator.  Plan check only, Electrical Fees paid under combination permit #19016-30000-15674	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30783	11041-20000-01046	12100 W WILSHIRE BLVD #480	90025	11	126B145   273	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	34.0438	-118.46755	PLAN CHECK T24 GENERAL/EMERGENCY LIGHTING REMODEL TO EXISTING SUITE #480.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30784	10041-20000-08069	5851 W CLINTON ST	90004	4	141B185   645	5523005003	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM	05/05/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.08176	-118.32967	Plan check T-24 energy for outdoor lighting loading dock . Lighting for sports and landscape are exempt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30785	16041-20000-32055	4530 N BAKMAN AVE	91602	2	168B173  1009	2366001023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Issued	09/09/2016 12:00:00 AM	ADDRESS	34.15307	-118.37776	Plan check for installation of roof-mounted solar array on SFD. Interconnect with 200A MSP. Derating main to 175A MSP. 10kW ungrounded system. One 300W optimizer per module. (36) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30786	12041-20000-16687	21700 W OXNARD ST 19th fl-coordr	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.17901	-118.60179	energy plan check 19th fl cooridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30787	10041-20000-08478	6402 N PLATT AVE	91307	3	180B093   746	2036024053	(Q)C1-1VL, (Q)C4-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	34.18692	-118.64252	Plan check T-24 Energy (general/emergency) lighting for fire damaged animal clinic. Replacing existing panel, installing new ckts, replacing existing AC, and installing LV devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30788	14041-10000-20694	441 W LEI MIN WAY	90012	1	135A215   183	5414011005	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM			Corrections Issued	07/31/2014 12:00:00 AM	ADDRESS	34.06493	-118.2377	Interior improvement. T24. Adding outlets, lighting, and power for A/C on the roof.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30789	16041-20000-13557	10100 N OWENSMOUTH AVE	91311	12	204B105   624	2747012010	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Expired	05/18/2018 12:00:00 AM	ADDRESS	34.2538	-118.60154	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (25) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30790	16041-20001-45576	475 N BEL-AIR ROAD	90077	5	141B153    56	4362014019	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.08476	-118.44163	04/05/2018 Plan check for power only. Project site is a 3-story SFD with an attached 7-car garage and a 2-story accessory living quarters. Work includes a 2,000-amp service and an optional standby generator and UPS system.permit fees paid under building combo permit.  see note below.Note: The building permit for the SFD has been issued under 16010-20000-03835 and for the accessory living quarters under 16010-20000-03836. Electrical plan set has been resubmitted due to a complete redesign of the electrical system for the SFD and the accessory living quarters.*****Previous Work Description*****Plan check for power only. New 2-story sfd  w/att. basement/7-car garage/liv. area and New 2-story accessory liv. quarter. 2,000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30791	19041-10000-16786	1708 N LINCOLN BLVD	90291	11	111B149  1323	4242010032	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM			PC Info Complete	05/29/2019 12:00:00 AM	ADDRESS	33.99666	-118.45772	T-24 PLAN CHECK FOR A TI OF A RETAIL STORE IN A MIXED USE COMEERCIAL-SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. NEW UPGRADED SERVICE TO 400A. TOTAL CONNECTED LOAD IS LESS THAN 400A. TOTAL AFFECTED AREA IS 1300 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30792	16041-10001-17687	8274 N SUNLAND BLVD	91352	2	192B173   562	2407024039	[Q]C2-1VL-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.22101	-118.3672	PLAN CHECK ONLY - SCOPE INCLUDES CLOUDED CHANGES - RELOCATION AND ADDITION OF LIGHTING AND NEW ADDED LOAD. ORIGINAL PLAN CHECK 16041-10000-17687PLAN CHECK FOR POWER AND  ENERGY .NEW SINGLE-STORY RESTAURANT BUILDING WITH A NEW 600 A SERVICE. TOTAL AREA FOR THE SCOPE IS 32,795 SQ FEET (IN/OUTDOOR).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30793	14041-20001-11621	16201 W SAN FERNANDO MISSION BLVD	91344	12	210B141   409	2681011039	C2-1VL, P-1VL, QC2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.27207	-118.48535	changes to approved set of plans. furiniture equipment change to 20A circuits. Also change in 1200A distribution. Tapping bus to supply 1200A distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30794	18041-20000-13780	4640 W HOLLYWOOD BLVD	90027	13	147B197   457	5542014007	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.10006	-118.29052	Tenant improvement for (E) office/playroom building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30795	14041-20000-01429	4814 N HASEKIAN DR	91356	3	168B121   249	2176031005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.15704	-118.55074	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30796	14041-20000-19185	11127 N SHARP AVE	91345	7	210B149   615	2664019014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Expired	08/31/2016 12:00:00 AM	ADDRESS	34.27277	-118.45385	PV1Central/String Inverter standard plan.Install roof mounted solar array on SFD. System size: 6kW.(1) PowerOne Aurora PVI-6000-OUTD-US-Z-A transformerless inverter(26) Trina Solar TSM-255 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30797	16041-10000-45042	701 S VERMONT AVE	90005	10	132B197   227	5094011024	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	04/22/2017 12:00:00 AM	ADDRESS	34.05952	-118.2918	Plan check for Title 24 only in existing space extension of juice shop to neighboring tenant space. Total area: 1064 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30798	15041-20000-38307	1340 E 6TH ST 4th Floor	90021	14	126A217   152	5164011001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	04/14/2016 12:00:00 AM		Issued	04/14/2016 12:00:00 AM	ADDRESS	34.03813	-118.23423	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from warehouse to manufacturing/tenant improvement to the 4th floor. Total lighting area = 40,400 sq. ft.Note: Building application has been filed under 15016-20000-10680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30799	19041-10000-52972	12580 W SATICOY ST BLDG C	91605	2	186B161   405	2305025022	M1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.2075	-118.40783	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30800	16041-10000-28837	14915 W ROSCOE BLVD	91402	6	192B149   371	2653023013	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.06	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.22163	-118.4582	PC FOR 10KW AC USING 32 MODULES. CENTRAL INVERTER SYSTEM CONNECTED TO 3 PHASE SERVICE.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30801	12041-10000-13594	2305 W COLORADO BLVD	90041	14	162A221    52	5671017014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM			PC Approved	06/12/2012 12:00:00 AM	ADDRESS	34.13975	-118.21652	Plan check for energy and emergency lighting. low-rise commercial. 902 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30802	13041-20000-13786	4624 W HOLLYWOOD BLVD	90027	13	147B197   481	5542014009	[Q]C2-2D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.0998	-118.29013	600 amp service upgrade to an existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30803	10041-20000-18098	14349 W FRIAR ST 1-18	91401	6	180B149  1015	2240012021	[Q]R3-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Public Safety Only			09/13/2010 12:00:00 AM	09/13/2010 12:00:00 AM		Permit Finaled	08/25/2011 12:00:00 AM	ADDRESS	34.1858	-118.44606	Plan check for new installation of fire alarm system for new 18 unit apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30804	19041-10000-31464	15489 W DUOMO VIA	90077	5	156B145   177	4378036002	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.124	-118.47064	[EPLAN] PLAN CHECK FOR NEW ESS(2 x TESLA POWERWALL) CONNECTED TO EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30805	19041-20000-14395	827 S CRENSHAW BLVD	90005	4	132B189   511	5090033005	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Issued	08/13/2019 12:00:00 AM	ADDRESS	34.05837	-118.32109	T24 PLAN CHECK FOR EXISTING HOMELESS HOUSING BUILDING. TOTAL SQUARE FOOTAGE = 953 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30806	16041-10000-34033	20908 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.21969	-118.58915	CONVERT RETAIL STORE TO A 7-ELEVEN MART;BNLDG # 16016-10000-22893	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30807	18041-10000-31301	1202 N AVENUE 54	90042	14	154-5A227  57	5478023031	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.11935	-118.19905	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 10KVA USING CENTRAL INVERTER(SE 10000A-US) WITH 34 PANELS WITH (P400) OPTIMIZRS.APPLICATION TIED IN WITH 18041-10000-31315 SAME PROPERTY	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30808	13041-10000-06866	4709 N LOWELL AVE	91042	2	201B205   734	2571005030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	PIN	34.24406234	-118.26662577	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. 14 PANELS AND 1 INVERTER. TRANSFORMERLESS WITH OPTIMIZER. SOLAR MODULES LOCATED ON SEPERATE STRUCTURE. NOT A METHANE ZONE. [INVERTER: SOLAR EDGE SE3000A-US] [SOLAR MODULE: TRINASOLAR TSM-240 PC/PA05].	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30809	15041-10000-19354	4151 W PROSPECT AVE BLDG A	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	T-24 ONLY TO AN (E)  2 STORY OFFICE BUILDING. SCOPE OF WORK INCLUDES ALL NEW LIGHTING IN BASEMENT, PC FOR ENERGY ONLT. TOTAL SQ. FT. 2153.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30810	15041-10000-39605	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	Energy plan check for a Kiosk T.I  (T4C-3301)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30811	11041-10000-11782	6801 W HOLLYWOOD BLVD SUITE 347-#D3-335	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM			PC Approved	07/07/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	TI TO AN EXISTING RETAIL SPACE IN A 5-STORY BUILDING.  PLAN CHECK FOR ENERGY ONLY, TAILORED METHOD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30812	19041-20000-03869	13921 W JUDD ST	91331	7	204B153    47	2618013026	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	ADDRESS	34.25976	-118.43649	Plan check for PV roof mounted system, system size: 7.5KW with 25 PV Modules and 1 inverter(6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30813	19041-10001-06682	818 E 3RD ST UNIT BA	90013	14	129A215   311	5163015016	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM	ADDRESS	34.04571	-118.23563	PLAN CHECK ONLY TO UPDATE THE PANEL SCHEDULE TO MATCH INSTALLED CONDITIONS PER APPLICANT REQUEST. PLAN CHECK IS FOR T-24 ENERGY ONLY AND DOES NOT COVER POWER. ORIGINAL WORK DISCRIPTION:PC T-24 only for Tenant improvement to existing restaurant. area 2960 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30814	16041-20000-05391	4444 N LANKERSHIM BLVD #108	91602	4	165B173   162	2423005011	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.15169	-118.36642	TI to (E) commercial retail space.  2116 sq. ft. plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30815	13041-10002-36244	7702 N SALE AVE	91304	12	189B097  1156	2013017009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	34.21031	-118.6184	"""Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.""Plan check only. PV1 CHANGES TO APPROVED: DOWNSIZE SYSTEM: PV1 10KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(2) inverters: {SOLAREDGE SE3800A-US & SE6000A-US}]. [(40)modules: {Trina {TSM-250PA05.18}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP300}]     old description:Roof mounted PV system with 12.75 KWdc for a one story house.  Install new125A PV subpanel.(2)Transformerless inverter(s): Solaredge SE 6000A-US. (51) Modules: Trina Solar TSM-250PA05.18.(51) Optimizers: Solaredge OP250-LVMC4SM-2NA-Z"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30816	17041-20000-00713	18518 W PARTHENIA ST	91324	12	195B125   900	2785004031	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Issued	01/12/2017 12:00:00 AM	ADDRESS	34.22805	-118.53686	ti to an existing commercial building.   adding new lighting and controls to existing panels.  newly connected load  ~400 amp.  plan check for power and energy.  total square footage 7446.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30817	14041-10000-27373	12887 W HAMMOCK LANE	90094	11	102B157   397	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	33.97471	-118.42039	Installation of new roof mounted solar PV system.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30818	15041-20000-34169	23314 W FRIAR ST	91367	3	177B093    36	2035020033	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Expired	01/17/2018 12:00:00 AM	ADDRESS	34.18526	-118.63467	PV1 SFD TOTAL SYSTEM SIZE 10.2KW AC USING TOTAL OF 2 CENTRAL INVERTERS AND 49 MODULES. SOLAR LOAD CENTER INCLUDED.Permit Fees $0 per California Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30819	15041-10000-21379	15232 W FOOTHILL BLVD	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2015 12:00:00 AM			Reviewed by Supervisor	08/14/2015 12:00:00 AM	ADDRESS	34.32292	-118.46695	PV1, INSTALL 3.27 KW DC ROOF-MOUNTD SOLAR ARRAY ON A SINGLE FAMILY HOME.(10) MODULES: SUNPOWER SPR327NE-WHT(1) INVERTER: POWER ONE PVI-3.0-OUTD-S-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30820	12041-10000-10822	6308 S 10TH AVE 1-12	90043	8	105B185   880	4006012008	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.00	Electrical	Electrical	Apartment			05/10/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	33.98255	-118.32777	New 3.2kw rooftop photovoltaic system for an existing apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30821	19041-20001-23523	22552 W NAPA ST	91304	12	192B097    49	2004016004	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.22564	-118.61836	07-01-2019 Changes to  an approved set of plan. Changes include re-route of conduit on roof. All Changes has been clouded.Plan check onlyFees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30822	18041-10002-46787	7101 S MENLO AVE	90044	8	102B197   992	6013001015	RD1.5-1	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			Reviewed by Supervisor	03/06/2019 12:00:00 AM	ADDRESS	33.97534	-118.28937	PLAN CHECK FOR LOST SET OF PLANS - ORIGINAL PERMITPV2 21.2 KW AC / 26.6 KW DC roofmounted system with (71) modules using p400 optimizers and (3) inverters solaredge (2)7.6kva and (1)6.0kva interconnecting through a main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30823	16041-20000-06677	9262 W NIGHTINGALE DR	90069	4	150B169  1376	5561007024	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	34.10344	-118.39091	Plan check for power only. New SFD - 2 STORY + BASEMENT APPROX 18,500 SQ. 1200A service.Note: Building permit has been issued under 15010-10000-03203	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30824	14041-10000-22509	6405 N INDEPENDENCE AVE SUITE  A	91367	3	180B109   597	2149003032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.18684	-118.59072	replace HID luminaires with fluorescent PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30825	17041-10000-19562	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.06488	-118.47066	PC FOR POWER AND ENERGY FOR TEMPORARY CLASSROOMS. TOTAL CONNECTED LOAD <400A  WITH NEW EQUPIMENT RATED AT 800ANEW FEEDERS AND SWITCH BOARDSTOATAL AFFECTED AREA 308,953 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30826	18041-10001-34846	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	Change to approved set by modifyig the single line diagram and adding ckt. All changes under delta-6 only.(((FULL PLAN CHECK  FOR INSTALLATION OF A NEW CHILLER PLANT FOR THE HVAC SYSTEM OF AN EXISTING 39 STORY OFFICE BUILDING; SCOPE INLCUDES: (1) NEW 400A DIST. BOARD, (1) 1000A DIST. BOARD, (1) 1200A DIST.BOARD (1) 100A SUBPANEL, NEW NORMAL/EMERGENCY LIGHTING AND RECEPTACLE IN THE AREA COVERS WITHIN THIS SOW. TOTAL AREA: 9,623 SQ.FT, (B# 18016-10000-29401))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30827	19041-10000-23520	7921 W 81ST ST	90293	11	096B153   206	4115027018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.9612	-118.43431	(ePlan) CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE UPDATING LOAD CENTER FROM 125A TO 200A AND MAKING ALL SINGLE POLE BREAKERS (AFCI)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30828	17041-10003-04627	20101 W RINALDI ST BLDG S2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.27545	-118.57197	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REVISING SITE PLANS FOR EV CHARGERS. CHANGES INCLUDE REVISING LOAD CALCULATIONS, FEEDERS, AND PANEL SCHEDULES FOR EV CHARGERS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30829	16041-20001-23053	21818 W YBARRA ROAD	91364	3	168B105   798	2171020038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM			PC Approved	07/20/2016 12:00:00 AM	ADDRESS	34.15408	-118.6016	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30830	19041-10000-08166	5643 N LANKERSHIM BLVD	91601	2	174B169   669	2338027012	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	34.17342	-118.38	FULL PLAN CHECK FOR CONVERSION OF EXISTING 1 STORY COMMERCIAL SPACE TO FOOD PROCESSING AND CATERING UNITS. SCOPE INCLUDES (1) 800-AMP SERVICE AND (8) PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30831	14041-20000-07763	4270 S LINDBLADE DR	90066	11	111B157  1171	4232017030	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			03/24/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	33.99629	-118.42232	New 2-story with mezzanine, 20 unit apt/subterranian garage.  New overhead 800A service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30832	18041-10000-39808	6300 N CANOGA AVE 12th fl.	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	34.18492	-118.59722	Plan check for T24 only, Tenant Improvement to (E) office building. Total area: 2,773 sq.ft  (B# 18016-30000-32818)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30833	17041-10000-38255	960 S SOTO ST	90023	14	123A221    12	5189009049	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Issued	10/24/2017 12:00:00 AM	ADDRESS	34.03262	-118.21655	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30834	14041-10000-23338	11803 W VOSE ST	91605	2	183B169   173	2321004018	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.19855	-118.38991	remove HID luminaires and replace with LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30835	12041-20000-30530	11999 W SAN VICENTE BLVD 260	90049	11	129B141   174	4404025029	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM			PC Approved	12/19/2012 12:00:00 AM	ADDRESS	34.05246	-118.47261	Plan check for energy. Permit under 12041-30000-27399. Customer states that all wiring is existing.2322 sqft. re-wire power switch plugs for new tenant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30836	18041-10000-26978	1374 W 35TH ST	90007	8	120B197   735	5040004025	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.02449	-118.29977	PLAN CHECH FOR FIRE ALARM SYSTEM ONSISTING OF 1 FIREALARM PANEL AND 57 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30837	15041-20000-20872	21042 W HEMMINGWAY ST	91304	3	189B105   287	2109014003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.21429	-118.59233	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30838	19041-20000-10066	545 W AVENUE 26 UNITS F-G	90065	1	142-5A219 112	5446011020	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Issued	04/30/2019 12:00:00 AM	ADDRESS	34.08494	-118.22345	PV3.  Install 18.84 kW roof mounted grid tied PV system.  (56) modules with (2) 7.6 and (1) 3.8 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30839	15041-20000-12554	910 S BROADWAY	90015	14	127-5A209 260	5139002017	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM			PC Info Complete	10/25/2016 12:00:00 AM	ADDRESS	34.04197	-118.25618	10/25/2016: Permit fees and original plan check were paid under 12041-20000-03714 (permit still active and ready for final by inspection).  This permit application has been changed to plan check only for the revisions to SLD design and distribution equipment layout in basement relative to approved set.  - Eric Goss(((Plan check for power and Title-24 (energy).  Total area = 22,740 sq. ft.  Complete remodel of existing commercial low-rise building.  Change from single meter to 9 meter, relocation of transformers.  New 1,000 amp service.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30840	13041-10000-33325	1470 S CANFIELD AVE 1-6	90035	5	129B169   162	4305006005	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Apartment			11/27/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.05312	-118.38933	NEW FIREALARM SYSTEM FOR APARTMENT/TOWNHOUSE. FULLY SPRINKLERED. 4 STORY BUILDING WITH PARKING. 2 PANELS AND 61 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30841	17041-10001-01663	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			Corrections Issued	02/17/2017 12:00:00 AM	ADDRESS	34.25052	-118.51258	EXPEDITE FEESPC FOR PV SYSTEM 10KW AC USING CENTRA INVERTER. USING POWER OPTIMIZERS. TOTAL OF 43 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30842	14041-10000-16170	11600 W WILSHIRE BLVD	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Expired	08/04/2016 12:00:00 AM	ADDRESS	34.05034	-118.45947	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CORRIDORS AND WAITING AREA ON THE 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30843	16041-10000-11512	16830 W VENTURA BLVD #100	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM			PC Info Complete	04/04/2016 12:00:00 AM	ADDRESS	34.15886	-118.50032	TENANT IMPROVENMENT TO (E) OFFICE SPACE ON FIRST FLOOR. INSTALL NEW LIGHTS AND CONTROL RECEPTACLES. PC FOR T-24 ONLY, TOTAL AREA: 1,484 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30844	17041-10000-24572	2212 E CENTURY BLVD 101-205	90002	15	091-5A217 111	6046019929	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/11/2020 12:00:00 AM	ADDRESS	33.94632	-118.23278	POWER PLAN CHECK FOR  3-STORY, 8-UNIT APARTMENT BUILDING; SCOPE INCLDUING A 400A SERVICE AND (9) PANELS. NOTE, THIS BUILDING IS ONE OF THE (16) BUILDING ON THE SAME SITE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30845	12041-10000-10794	17433 W TRAMONTO DR	90272	11	126B117   195	4416004034	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2012 12:00:00 AM			Reviewed by Supervisor	08/22/2012 12:00:00 AM	ADDRESS	34.04246	-118.55696	Plan check for new accessory building (approx 3,099 sq ft) supplied from main house plan check under #12041-10000-10793. (Submittal 2 of 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30846	19041-10000-04531	13100 N ELDRIDGE AVE	91342	7	225B161    47	2580015904	OS-1XL	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Closed	02/07/2024 12:00:00 AM	ADDRESS	34.30942	-118.41434	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30847	17041-10001-04741	2580 W OLYMPIC BLVD	90006	1	129B197   330	5076008018	C2-2D	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.05219	-118.28726	"1ST REVISION TO APPROVED PLAN NOTED AS DELTA-2, SOW INCLUDES:  ADD (1) 100A PANEL 'C"" WITH 26 NEW CIRCUITS TO (E) DP DIST. BOARD.; REVISE LIGHTING FLOOR PLAN AND T24 ACCORDINGLY.                 <<NEW SANDWICH SHOP AND OFFICE. INCLUDES NEW 600A 120/240 MAIN SERVICE FEEDING THREE STRUCTURES SHARING THE SAME METER, ROOF AND PATIO. PC FOR POWER AND ENERGY. TOTAL AREA IS 23812SQFT. ALL THREE BUILDINGS UNDER THE SAME BUILDING PLAN. BUILDING PERMIT 16010-10000-04748.>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30848	16041-20000-12943	10967 N GOTHIC AVE	91344	12	210B137   679	2680022029	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.27005	-118.48923	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (20) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30849	13041-10000-07171	6100 S GRAMERCY PL	90047	8	105B193   685	6001018010	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	33.98415	-118.3133	PHOTOVOLTAIC SYSTEM FOR COMMERCIAL BUILDING. PV2. USING TOTAL OF 416 PANELS. CENTRAL INVERTER RATED 85KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30850	18041-10000-23847	1030 N SWARTHMORE AVE 3-105	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	"Tenant imrpovement to retail space ""ALC"" (Suite# 3-105) within Pacific Palisades Village shopping Center.Full plan check for power and energy. First Time Tenant."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30851	13041-10000-22253	2138 W BAXTER ST	90039	13	145-5A209 323	5422021012	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.09184	-118.25624	PV1. 2 STORY HOUSE. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 12.25KW. TRANSFORMELESS INVERTER. 50 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30852	14041-20000-19214	16844 W FLANDERS ST	91344	12	213B133   614	2610005018	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.27997	-118.49947	PV1.  Install 5.98 kW roof-mounted, utility-interactive PV system.  Central/string inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30853	13041-10003-03297	303 S PACIFIC AVE	90731	15	018B197  1575	7451018900	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Apartment			06/13/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	33.7413	-118.28819	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS. CHANGES INCLUDE NEW PANEL SIZE FOR GH2 AND REDESIGNATE HOME RUN CIRCUITS ON PANELS GH1 AND 2. NEW FLOOR PLAN AND UPDATED PANEL SCHEDULES PROVIDED. NO OTHER NOTED CHANGES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30854	19041-10000-15206	3501 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.02194	-118.28455	REPLACING AN EXISTING 30 kw EMERGENCY GENERATOR WITH A NEW 80kw.  ADDING NEW LOAD AND LIGHTS. PLAN CHECK FOR POWER & ENERGY. BUILDING PERMIT: 19020-10000-01113	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30855	18041-10001-15639	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	Change to approved set by updating lighting plan, and new circuits. All changes under delta-2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30856	19041-10000-27518	15500 W ERWIN ST	91411	6	177B145   347	2242001007	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.1828	-118.47086	REPLACE INDOOR AND OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30857	16041-10000-03316	1663 W 204TH ST # D	90501	15	054B193   121	7351005002	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	33.84588	-118.3088	PV1,  ROOF-MOUNTED SOLAR ARRAY SIZED 3.0KW  ON A SINGLE FAMILY HOUSE.(8) MODULES: KYOCERA KU255-6XPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30858	17041-20001-20414	19536 W WELLS DR	91356	3	171B117   397	2175011010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2017 12:00:00 AM			PC Approved	06/25/2017 12:00:00 AM	ADDRESS	34.1635	-118.55916	expeditepv1install roof mounted pv system sized 12kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30859	12041-10000-16075	13033 W VENTURA BLVD #B	91604	2	165B161   947	2375020017	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.14585	-118.41713	Nonstructural interior T.I.  NO CHANGE IN USE.  Load is less than 400A and occupancy load is less than 99, per applicant.  PLAN CHECK ONLY for Energy, NO Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30860	14041-10000-03481	3322 W SUNSET BLVD	90026	13	142-5A203  16	5426007018	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.08694	-118.27577	PLANCHECK FOR T24ENERGY. DUE TO LOST PLANS. TENANT IMPROVEMENT FOR EXISTING RESTAURANT. 1 STORY. 1357 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30861	15041-10001-39592	1601 N VINE ST	90028	13	148-5A187 301	5546009906	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Approved	03/20/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	RECHECK AND RESTAMP PLANS FOR CHANGES NOTED DELTA 3. REMOVE PULL STATIONS. LEAVING 1. PC ONLY. PERMIT STILL COVERED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30862	15041-10000-36915	175 E 48TH ST	90011	9	111A205    86	5109003022	R2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	33.99936	-118.27254	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.5KW INTERCCONNECTED WITH MSP.(36) MODULES(1) 7.5KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30863	13041-10000-23601	1229 S WESTMORELAND AVE	90006	13	129B197   910	5076019029	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Apartment			08/29/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.04818	-118.2893	PV2.  Install 15 kW solar array on existing apartment building's Class A roof, interconnect into existing 400A main service panel. 690.64B2. fault description is 42k	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30864	18041-10000-15219	7300 WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	33.93972	-118.42295	PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT TO BUILD-OUT NEW OFFICES, TRAINING ROOM, CONFERENCE AND STORAGE ROOMS. RENOVATE EXISTING OFFICE AREAS FOR REUSE. BUILD NEW EQUIPMENT ROOMS AND STORAGE/SHOP AREA.  39,187 SF PROJECT AREABUILDING PERMIT # 18016 10000 11663	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30865	19041-10000-50998	1101 N MAIN ST	90012	1	135A217   504	5409006042	UC(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Apartment			12/11/2019 12:00:00 AM	02/03/2020 12:00:00 AM		Permit Finaled	12/20/2021 12:00:00 AM				PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OG WORK IS 2 NEW FIRE ALARM PANELS, 26 REMOTE POWER SUPPLIES AND 1057 FIRE ALRM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30866	16041-10001-04741	3165 W 6TH ST	90020	13	135B197   953	5077003013	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.06383	-118.29074	Revision to approved plan to add 4 sensors. Riser diagram, floor plan, and battery calculation are revised accordingly.<<Install new METHANE mitigation/Detection for an Ihop Restaurant. (1) Panel  (14) devices.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30867	15041-10001-02656	149 S BRISTOL AVE	90049	11	132B137   550	4406011009	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	34.05547	-118.48834	Expedite per applicant request. ((((((Plan check for PV roof top. System size: 11.4kw with 3 strings and 46 modules.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30868	17041-10000-19426	7430 N HAYVENHURST PL	91406	6	186B137   198	2205010905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.20557	-118.49179	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30869	18041-20000-29486	11601 W WILSHIRE BLVD 600	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30870	19041-10000-52482	2360 W VENICE BLVD	90019	10	126B193  1424	5073012030	C2-2D-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM			PC Info Complete	11/03/2021 12:00:00 AM	ADDRESS	34.04335	-118.31062	FIRE VARIENCE IS NOT SUBMITTEDFULL PLAN CHECK FOR TWO SERVICES AT 1600A  AND 4000A, SERVICE SIZE IS 120/208V. 4 RESIDENTIAL SWITCHBOARDS AT 1000A EACH WITH 180 RESIDENTIAL SUBPANELS. SCOPE OF WORK INCLUDES (3) 40HP ELEVATORS AND 3 7.5HP BOOSTER PUMPS. TOTAL  AFFECTED AREA IS 166,677 SQUARE FEET.BUILDING APPLICATION NUMBER: 19010-10000-05631	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30871	14041-10000-07872	13730 W ROSCOE BLVD admin bldg	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.22149	-118.43179	Ti, title 24, 2 story bldg, emergency lighting  unit equipment.  admin area no pataint care	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30872	17041-10000-30521	3201 S HOOVER ST 1830	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.0255	-118.28448	Plan check for 1st time tenant power and energy. Toal area: 1,300 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30873	16041-10000-17393	6230 W YUCCA ST	90028	13	148-5A189   5	5546030029	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.10353	-118.32572	PC FOR POWER AND ENERGY .NEW 18-STORY 114 UNIT APARTMENT WITH GARAGE WITH 1200A TEMP POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30874	19041-10000-25062	1609 W LOCKNESS PL	90501	15	045B193   408	7347017043	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM			PC Info Complete	06/28/2019 12:00:00 AM	ADDRESS	33.81827	-118.30584	Energy plan check for a change of use from warehous/office to nursery/retail/office. Scope includes new lighting and equipment with a total area of 1,840-SQ FT.Bld #: 17016-10000-36603.(((CHANGE OF USE FROM STORAGE WAREHOUSE/OFFICE TO INDOOR NURSERY/RETAIL/OFFICE. TENANT IMPROVEMENT TO INLUCDE NON LOAD BEARING PARTITIONS & FINISHES. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30875	12041-10000-07193	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	Existing commercial building.  New 3000A service, new panels, equipment, circuits, in a 5-story 90,778 sq ft building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30876	12041-20000-03245	1990 S BUNDY DR s.420	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.03419	-118.45559	office t.i.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30877	18041-20001-06809	6350 N LAUREL CANYON BLVD #410	91606	2	180B165   762	2334003027	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.18619	-118.39631	Plan check for Title 24 only in existing space office T.I. lighting and receptacle. Total area: 5809 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30878	12041-20001-10698	5340 S ALLA ROAD	90066	11	102B157    39	4211008023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	33.9773	-118.42567	Changes from previously approved plans.  Changes in general lights fixtures.  Plan check for energy only.*****S.103 OFFICE T.I. ENERGY, EMERGENCY*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30879	16041-20000-37108	22950 W VANOWEN ST Suite C	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Issued	10/20/2016 12:00:00 AM	ADDRESS	34.19343	-118.62746	Plan check for Title 24 only. Project site is an existing commercial suite. Project scope is bathroom lighting. Total lighting area = 117 sq. ft.Note: Building application has been generated under 16016-20000-25107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30880	16041-10000-41389	13859 W RUNNYMEDE ST	91405	2	186B153   246	2215007001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Reviewed by Supervisor	12/06/2016 12:00:00 AM	ADDRESS	34.20585	-118.43538	PV, NEW 11.2 KW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE WITH DETACHED GARAGE. (40) MODULES: SUNIVA OPT280-60-4-1B0(40) MICROINVERTERS: ENPHASE M250-60-2LL-S22PLAN CHECK ONLY. PERMIT WAS PULLED UNDER # 16041-10000-32076	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30881	17041-10003-04642	20111 W RINALDI ST BLDG S6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			PC Approved	08/16/2019 12:00:00 AM	ADDRESS	34.27542	-118.57218	Sppl Plan check per inspector's request, to verify the AIC at the Skid Pump located about 325 feet from panel LS6 with 32.6KAIC fed from a 60 Amp circuit with #2AWG wires to be about 4.4 KAIC.**Plan Check Only**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30882	15041-10000-35960	262 S VAN NESS AVE	90004	4	135B189   154	5516010012	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.06926	-118.31542	PV1, ROOF MOUNTED SOLAR SYSTEM, TOTAL SIZW IS 6KW. (22) MODULES AND (1) INVERTER. (22)SUNPOWER 327W MODULES TOTAL. (1)POWER ONE-6000-OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30883	18041-20000-46072	13766 W SATICOY ST	91402	6	186B153    49	2214023007	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.20967	-118.43332	Plan check for Title 25 Energy only for lighting in the2 bath rooms. Total area: 128 sq ft.B#18016-20000-33491	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30884	16041-20001-32525	7052 N MATILIJA AVE	91405	2	183B153   391	2216029007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.19913	-118.43331	Revisions to approved standard plan.  (E) panelboard changed to indicate center-fed, derating of main breaker to accommodate PV load.  (((Plan check for a PV1 roof-mounted PV system. System size  is 5 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30885	14041-10000-16859	12555 W JEFFERSON BLVD 150	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	33.97954	-118.41361	PLANCHECK FOR T24 ENERGY. OFFICES. TENANT IMPROVEMENT. NO CHANGE IN OCCUPANCY. 4 STORIES. SUITE 150. 3600 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30886	15041-10000-35449	9857 N RATHBURN AVE	91325	12	201B125    95	2764002001	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM			Reviewed by Supervisor	11/03/2015 12:00:00 AM	ADDRESS	34.24968	-118.53319	PV1, INSTALL 12.426 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (38) MODULES: SUNPOWER SPR-327-NE-WHT-D(2) INVERTER: POWER-ONE PVI-6000-OUTD-US-A 240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30887	18041-10000-31952	689 S CATALINA ST	90005	10	132B197   192	5094007002	C4-2, R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			08/22/2018 12:00:00 AM	07/27/2021 12:00:00 AM		Permit Finaled	09/27/2023 12:00:00 AM	ADDRESS	34.0603	-118.29559	FULL PLAN CHECK FOR NEW 1200A SERVICE FOR NEW APARTMENT BUILDING WITH RETAIL AND PARKING. NEW SERVICE EQUIPMENT, PANELS, LIGHTING, AND POWER LOADS. TOTAL SQUARE FOOTAGE = 55105  SFBLDG PERMIT: 18010-10000-02473	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30888	16041-20001-44611	12500 N GLADSTONE AVE	91342	7	219B161   168	2525019062	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.29734	-118.41327	Revisions to approved set of plans.  Change of service conductors from (3) sets of 600 MCM to (3) sets of 500 MCM.  (((Plan check for power only. New 1200A service (replacing 1600A service of same voltage class and phase). Reconnect existing feeders and equipment to new distribution board.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30889	15041-20000-25571	8422 N MCNULTY AVE	91306	3	192B109   454	2780004071	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.2228	-118.58704	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30890	13041-20000-11380	7657 N PASO ROBLES AVE	91406	6	186B133    53	2203011002	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.21	-118.50246	photovoltaic system for single family dwelling. total system size 5.6 kw. 2 strings. transformerless inverter. nonstandard plan. pv1 system. using 23 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30891	19041-10001-49291	1836 N LAUREL CANYON ROAD	90046	4	150B177   423	5569034008	R1-1-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.10467	-118.36611	EXPEDITE PER APPLICANT REQUESTNEW ROOFTOP SOLAR SYSTEM CONSIST OF 41 MODULES (Q-PEAK 380) WITH 41 OPTIMIZER ( SE P400) AND 2 CENTRAL INVERTERS (SE 7600H-US EACH). SYSTEM SIZE IS  15.58KWDC AND 15.2KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30892	19041-10000-45912	970 S FEDORA ST	90006	10	132B197  1191	5078004021	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Apartment			11/13/2019 12:00:00 AM	07/02/2020 12:00:00 AM		Permit Finaled	11/12/2021 12:00:00 AM	ADDRESS	34.05355	-118.29776	FULL PLAN CHECK FOR A NEW 2,000A 120/208 3PH 4W SERVICE. SCOPE INCLUDES 50 x 125A PANELS, 2 x 800A SWITCHBOARDS, 25HP ELEVATOR, EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 28,397 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30893	15041-20001-37382	7900 N BALBOA BLVD BLD. LIMA	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM			PC Approved	11/10/2015 12:00:00 AM	ADDRESS	34.21347	-118.50092	**11/10/15: Plan check only, applicant request per inspector**Permit fees paid under PCIS#15041-20000-37382200AMP (N) SERVICE. INSTALL (N) SUB-PANELS AND CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30894	18041-10000-26682	5818 W PICO BLVD	90019	10	129B177   498	5068022001	C4-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	03/07/2019 12:00:00 AM		Issued	03/07/2019 12:00:00 AM	ADDRESS	34.05106	-118.36522	PC FOR TENANT IMPROVEMENT TO (E) RETAIL FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHT AND RECEPTACLES. TOTAL AFFECTED AREA 4532 SQ.FT B#18016-10000-00336	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30895	19041-20000-48676	18450 W VENTURA BLVD	91356	3	171B125   100	2161021046	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	03/09/2020 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.16825	-118.53517	Replacement of existing 600A 208Y/120V 3ph-4w service, distribution, new power and lighting. Plan check for power and energy.  T24 included total square footage = 1323 sf	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30896	19041-10000-21619	14947 W MALDEN ST	91402	6	192B145   101	2653012024	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.22567	-118.45924	$0.00 fee per AB1414. PV1. PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 11.4KWac/ 12.68KWdcSCOPE INCLUDES 43 MODULES (SW 295), OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTERS (SE 11400A-USR GM).	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30897	13041-20000-17255	16886 W CHARMEL LANE	90272	11	135B117   119	4420035020	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.06401	-118.55148	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.3 KW USING 28 MODULES. USING ENPHASE MICROINVERTER ENPHASE M215.  PLAN CHECK IS FOR THE PV SYSTEM ONLY, NOT FOR THE SERVICE UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30898	11041-10000-21215	21013 W SHERMAN WAY	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM			PC Approved	10/04/2011 12:00:00 AM	ADDRESS	34.20125	-118.5914	T.I. to an existing retail store.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30899	12041-10000-19473	3515 W WILSHIRE BLVD Floors1 &2	90010	10	132B193    16	5502032017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.0619	-118.30094	MAJOR TI IN AN EXISTING HIGH RISE HOTE;  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30900	14041-20002-13967	11130 N BALBOA BLVD A	91344	12	210B133   327	2682021032	C2-1VL, C4-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	34.273	-118.50196	10-28-2014: Changes to approved set. Delta 2 changes only. Remove fixture A. Changes to Title-24 only.[[[10/27/14 changes to approved set. delta 1 changes only. removing chandeliers. changes to t24 only]]]]Change of use from retail to banquet hall.    Install new branch circuits and lighting.  Plan check for power and energy.Expedite fee paid 06/03/14occupancy 984 occupant by building code permit # 14016-30000-07644	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30901	16041-10001-38084	10250 W SANTA MONICA BLVD # 1813	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"REVISIONS 1 & 2 TO PERMITTED SET OF PLANS: NEW CIRCUITS; NEW TYPES OF LUMINAIRES; RECALCULATED VOLTAGE DROPS AND SHORT CIRCUIT VALUES.(CHANGES ARE INCLUDED UNDER DELTA 5) ((((((((Full PC for New Tenant ""Kendra Scott"" Ste. 1813.  Install new panels and its circuits, lights and receptacles. Total effected area: 897 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30902	16041-20000-10159	3015 S WEST VIEW ST	90016	10	120B177   677	5049034015	R2-1, [Q]C1.5-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			03/23/2016 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.02647	-118.35328	PLANCHECK FOR POWER AND ENERGY.  4-story apartment building with 1-level subterranean garage64 unit apt (31 for Seniors/32 for Veterans/1mgr). VARIANCE HAS BEEN SUBMITTED FOR FIREALARM. PRE CUT CHECK PLANCHECKER TO VERIFY FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30903	17041-10001-43737	7242 N VALJEAN AVE	91406	6	186B137   367	2205027029	MR1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM			Reviewed by Supervisor	12/11/2017 12:00:00 AM	ADDRESS	34.2024	-118.48575	Fees for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30904	15041-10000-25498	1425 N WATERLOO ST	90026	13	142-5A207   5	5424022029	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Approved	08/06/2015 12:00:00 AM	ADDRESS	34.08271	-118.26452	Energy plan check for outdoor lighting located in the common area of a multi-dwelling units site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30905	19041-20001-13387	5900 W WILSHIRE BLVD Suite 750	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	04/26/2019 Plan check for a lost set of plans. Scope of work has remained the same. Electrical permit has been issued under the master application.*****Original Scope of Work*****TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30906	10041-20000-05897	1494 N MORAGA DR	90049	5	147B145   212	4377039007	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2010 12:00:00 AM	04/01/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	ADDRESS	34.09492	-118.46897	addition to existing single family new 600 A service plan check single line diagram	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30907	18041-20000-06713	3317-3325 W EXPOSITION PL	90018	10	120B185  1411	5044002012	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2342.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.02152	-118.33233	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30908	14041-10000-09240	1458 S SAN PEDRO ST # 101	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures. Total area 1531 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30909	17041-20001-12879	1520 W JAMES M. WOOD BLVD system a	90015										Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			Verifications in Progress	05/18/2017 12:00:00 AM	ADDRESS	34.05009	-118.27201	expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30910	16041-10000-06252	1828 S WESTERN AVE	90006	10	126B193   744	5074015051	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.04091	-118.30873	"02/23/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES MADE UNDER DELTA 4. CHANGES INCLUDE FEEDER LENGTHS, OCPD SIZES, LOAD CALCULATIONS,  AND ADDING TWO 4"" CONDUIT FOR FEEDERS.NOTE: PERMIT PAID UNDER PCIS#15041-10000-09305((((((ADDING NEW SECTION TO AN EXISTING DISTRIBUTION BOARD IN LIVE/WORK UNITS.  ADDING NEW PANELS AND CIRCUITS.  PLAN CHECK FOR POWER ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30911	10041-20000-02515	12000 N BALBOA BLVD #108, 109,-110	91344	12	216B133   344	2610001006	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM	02/16/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.28784	-118.5018	"ADD FULL HEIGHT PARTITION WALL(20' lengh) BETWEEN OFFICE AREA & AUTO REPAIR AREA.""Comply with Department order effective date 02/09/2010"".Energy"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30912	18041-20002-38172	10965 W ELINDA PL	91352	7	201B173   373	2538013011	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.24456	-118.36981	10/30/2018changes to an approved set of plans.  changes to redesign module strings and terminations.  no change in system size. this is plan check only.  (((Plan check for PV roof mounted system, system size: 17.49KW DC, 16.086KW AC with 53 PV Modules and 53 Microinverters connected to 225A Panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30913	14041-20000-18021	12921 W MINEOLA ST	91331	7	201B161   846	2626011002	RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.24487	-118.41372	4.4KW PV1 roof-mounted system with (16) Enphase M215 microinverters and Hyundai 250W modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30914	15041-20000-06685	11083 N EL DORADO AVE	91331	7	210B157   443	2616029036	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.2712	-118.43171	Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  16 modules with miroinverters on 1 branch circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30915	11041-10000-26105	10250 W CONSTELLATION BLVD 27nd fl	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM			PC Approved	12/07/2011 12:00:00 AM	ADDRESS	34.05735	-118.41746	alterations in existing offices; plan chk is for lighting compliance with energy code and for emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30916	19041-10000-11416	777 S FIGUEROA ST 45TH FLR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Energy plan check for an office T.I. Scope includes new lighting and equipment with a total area of 650-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30917	16041-10000-39444	350 S FIGUEROA ST 580	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.05438	-118.2549	T-24, PC FOR ENERGY ONLY. TI TO AN ( E ) OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2974 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30918	12041-10001-26723	16450 W VENTURA BLVD	91436	5	168B137   385	2284002044	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.15731	-118.49192	unable to reuse three existing 600A distribution boards as the AIC ratings were not available; two of the distribution boards were replaced ( 22KAIC) AND THE THIRD WAS REPLACED WITH FUSED DISCONNECT SWITCH  (22KAIC)((((((((((Plan check for service upgrade from 240V to 480V. Gelson's Market. New 2000A service, 2000A panel, seven 150kVA transformers, and one 75kVA transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30919	13041-10000-35807	1530 S HAYWORTH AVE	90035	10	129B173   893	5068021019	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			12/23/2013 12:00:00 AM			PC Info Complete	04/24/2014 12:00:00 AM	ADDRESS	34.04898	-118.36808	PLAN CHECK FOR POWER AND ENERGY FOR A NEW 8 UNIT APARTMENT BUILDING, 3 LEVELS OVER 1 LEVEL SUBTERRANEAN PARKING. METHANE ZONE. VARIANCE HAS BEEN SUBMITTED TO SEPERATE FIRE ALARM.BUILDING P # 13010-10000-04295	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30920	15041-20000-30785	18119 W MIRANDA ST	91356	3	174B125   230	2157010032	R1-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Closed	10/31/2018 12:00:00 AM	ADDRESS	34.1746	-118.52807	PV 1,  7.6 kWAC KW Pv array, (1) inverter: #Primo 7.6, label A, (33) modules: KYOCERA #KU2656ZPA.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30921	10041-20000-21506	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM			PC Info Complete	10/28/2010 12:00:00 AM	ADDRESS	33.78734	-118.29768	Plan check request by customer for Kaiser LAN upgrade consist of new UPS, panels, xfrmr, and ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30922	13041-20000-14164	8944 N FULLBRIGHT AVE	91311	12	195B113    38	2781001023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.23337	-118.57739	BUILD OUT OF WARE HOUSE UNITS IN OPEN SPACE. EXISTING EQUIPMENT. PC FOR T24 ENERGY ONLY. NEW CONNECTED LOAD < 400A. BUILD OUT FOR TENANTS A1 AND B1. TOTAL AREA 16898 SQ FT. T24 ENERGY ONLY. PERMIT ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30923	17041-10000-02858	1149 S BOYLE AVE #203	90023	14	123A219   117	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.03001	-118.22065	Plan chekc for Title 24 only in existing space T.I. Total area:  2,585 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30924	14041-10000-12763	631 W 28TH ST	90007	9	121-5A203 112	5123015406	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Expired	06/07/2016 12:00:00 AM	ADDRESS	34.02663	-118.27827	Plan check for fire alarm, with one new panel for a two story house.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30925	18041-20000-21208	9958 W SHADOW HILLS DR	91040	7	204B181   161	2543013032	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.25804	-118.34884	Plan check for PV ground mounted system. System size: 6.0kW with 25 modules and 1 inverter(6.0kW)Building Application number: 18020-20000-01647	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30926	14041-10000-31657	11517 N LEXICON AVE	91342	7	213B169   635	2530019027	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.27922	-118.37995	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.905 KW(15) MODULES (1) INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30927	10041-20000-00214			13	135A207    44	5159008024	RD1.5-1	Central	Westlake	Greater Echo Park Elysian	YES	2084.02	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM			PC Approved	01/06/2010 12:00:00 AM	PIN	34.06580852	-118.26560346	CHANGE ELEVATOR SIZE AND SERVICE SIZE AND ELIMINATE WATER HEATERPLANS INCORPORATED WITH ORIGINAL SET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30928	15041-20001-07078	17302 W OSBORNE ST	91325	12	195B133   132	2768018013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.23324	-118.51172	Expedite per applicant request(((((Plan check for PV system roof mounted system with 36 enphase microinverter 250. Total system size: 9kW)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30929	11041-10000-11487	603 S GAFFEY ST	90731	15	015B197   364	7451035025	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	33.73862	-118.29255	ALL NEW ELECTRICAL SYSTEM FOR A TI TO AN EXISTING GROCERY STORE.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30930	13041-20000-35348	4912 N PLACIDIA AVE	91601	4	168B177   221	2420011014	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.15989	-118.35593	PV1 TRANFORMERLESS SYSTEM. USING COMBINER BOX. 36 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30931	12041-10000-10393	1420 W 27TH ST	90007	8	123B197  1342	5054032003	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM			Verifications in Progress	10/03/2012 12:00:00 AM	ADDRESS	34.03029	-118.29223	PLAN CHECK NEW INSTALLATION OFA 16.6 KW DC PHOTOVOLTAIC SYSTEM ON THE ROOF OF AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30932	15041-20003-39703	13650 W BURBANK BLVD	91401	4	174B157   611	2344001014	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.17196	-118.43072	06/27/2016 Plan check for a lost set of plans. Project scope has not changes. Plan check for Title 24. Project scope is a tenant improvement. Total lighting area = 866 sq. ft.*****Previous Work Description*****02-03-16 Change to approved set of plans. Changese include addition lighting fixtures. Changes apply to delta 1 only.  {{{{{{{Revisions made to approved set.  Inclusion of (E) lighting into lighting plan and change of panel location.  (((PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM (E) RETAIL TO (N) BEAUTY SALON.  866 SQFT.)))}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30933	13041-10000-04379	464 N FAIRFAX AVE	90036	5	141B177  1186	5527030026	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			PC Approved	05/06/2013 12:00:00 AM	ADDRESS	34.07996	-118.36125	PC FOR TITLE 24 AND EMERGENCY LIGHTING . ADDING NEW LOAD TO EXITING PANEL (<400A) OCCUPANCY LOAD LESS THAN 100 (~88 OCCUPANTS).CONVERT 1ST FLOOR BANK TO RETAIL.  INCLUDES INTERIOR REMODEL AND DOOR RENOVATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30934	18041-10000-07050	541 N SANFORD AVE	90744	15	030B209   530	7424014095	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.7773	-118.2506	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 11400 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30935	18041-20000-23094	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.08901	-118.34188	Plan check for power and energy change of use from part of office building to Medical Clinic 4th, 5th, and 6th Floor. T.I. to existing service equipment. Total area: 47,413 sq ft. B#18016-20000-15553	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30936	14041-20001-17848	675 N FRONT ST	90731	9	021B201   203	7448035907	R4-1VL	Central			Y	2074.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	33.75	-118.28209	[[1/27/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. DELTA 1 CHANGES]]]]]PC FOR POWER. REMOVE AND REPLACE ATS, GENERATOR, VFDs, PUMPs, MOTORs FOR CITY OF LA, SANITATION DEPARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30937	18041-10000-28148	1030 N SWARTHMORE AVE #2-106	90272	11	129B125   468	4423016025	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Full plan check for first time to existing retail space within Pacific Palisades Village. New step down transformer and 100A panelboard for the tenant for lightings and power. Total area: 563 sq.ftB# 18016-10000-23722	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30938	18041-20002-37378	7701 N WOODLEY AVE	91406	6	186B137   423	2205010905	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.20948	-118.48389	4/18/2019changes to an approved set of plans.  changes noted delta 3 only.  changes to remove MTS and add additional circuits.plan check for power.   ((((Plan check for power only. Project site is an existing commercial building (existing hangar at Van Nuys airport). Project scope is a new 800 amp serive at 4.8KV feeding a 2,000-amp switchgear which will re-feed existing distribution equipment and loads.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30939	14041-20003-28799	11430 W BURBANK BLVD	91601	2	174B169   839	2350004033	C4-1, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.17184	-118.38	Changes made to approved set.  Addition of panels and loads to commercial tenant spaces.  -------------------------------------------NEW MIX USE APARTMENT BUILDING (2) SERVICES (1) 2000 AMP SERVICE (1) 1200 AMP SERVICE FIVE FLOORS WITH ONE UNDERGROUND PAKING LEVEL.  125 UNITS.  PLAN CHECK FOR POWEER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30940	16041-10000-41745	4561 E LINCOLN AVE	90041	1	156A221   101	5474019022	M1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.12254	-118.21652	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 37960 SQ FT. (INDOOR+ OUTDOOR LIGHTING)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30941	14041-10000-10191	4161 N FARMDALE AVE	91604	2	162B169    52	2368022016	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.14418	-118.38128	PV1 2.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(10)modules: {Trina {TSM-250PA05.08}}]SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30942	15041-10001-32873	22141 W LONDELIUS ST	91304	12	195B101   248	2010007032	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.22943	-118.60978	EXPEDITED RSES PER APPLICANT REQUEST.<<<PV1, INSTALL NEW 14.04 KW DC ROOF-MOUNTED SOLAR ARRAY FOR  RESIDENTIAL BULDING. (52) MODULES: LG 270 W (2) INVERTER: SMA SUNNY BOY SB-7000TL-US AND SMA SUNNY BOY SB-6000TL-US>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30943	10041-10002-24663	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Info Complete	04/08/2014 12:00:00 AM	ADDRESS	34.05373	-118.26606	plans lost. this application is plan check only. [][][][] CHANGES MADE TO AN APPROVED SET OF PLANS FOR A 7 STORY MEDICAL OFFICE BUILDING; CHANGES IS FOR RELOCATING FIRE PUMP SECTION AT THE SWITCHGEAR, ADDING (2) 75KVA XFORMERS, (6) PANELBOARDS, AND ADDING LIGHTING FIXTURES (IN STAIRS, EVS ROOM, ROOF AREA)  PHONE CONTACT EXTENSION 208 [][][][ NEW 7 STORY MEDICAL OFFICE BUILDING. CORE & SHELL ONLY. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30944	16041-10001-16078	820 S SPRING ST	90014	14	127-5A211 243	5144016047	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.04255	-118.25395	Additional 2 duct detectors.<APPLICATION IS FOR PLAN CHECK ONLY; INSTALL A FIRE ALARM SYSTEM FOR THE FACILITY. 3 stories, 7 units appartment. permit already issued under12041-10000-12123. Original plan check number: 12041-10000-15655.>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30945	17041-10000-46673	10601 W WASHINGTON BLVD	90232	5	117B165   262	4208009049	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	04/25/2018 12:00:00 AM		Issued	04/25/2018 12:00:00 AM	ADDRESS	34.0175	-118.40491	Plan check for first time tenant new mixed use building Starbucks Coffee. Total area: 1820 sq ft. #17016-10000-38469	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30946	14041-20000-23163	7261 N CIRRUS WAY	91307	12	186B093   687	2027010022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.20206	-118.63672	PV1 SFD. TOTAL SYSTEM SIZE 6.6KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. DERRATING MAIN BREAKER. USING TOTAL OF 32 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30947	12041-10000-23021	4301 W 3RD ST	90004	10	135B193   200	5517007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	05/03/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	PIN	34.06916769	-118.30825671	NEW CONSTRUCTION FOR A MULTI LEVEL PARKING GARAGE. EPC IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30948	19041-10000-27496	7249 N LANKERSHIM BLVD	91605	2	186B169   914	2317019033	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.20256	-118.38798	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30949	15041-10000-31422	303 S LOMA DR	90017	1	133-5A207 207	5153007022	C2-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.05979	-118.26586	PC FOR POWER AND ENERGY. CHANGE OF USE FROM AN EXISTING OFFICE BUILDING TO CLASSROOMS (SCHOOL). TOTAL AREA IS 3713 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30950	18041-20000-25033	515 S FIGUEROA ST STE 380	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI TO AN EXSTING COMMERCIAL BUILDING (HIGH RISE).  ADDING NEW LIGHTING NEW CONTROLS  TO EXISTING CIRCUITS.  EXISTING ON SITE GENERATOR TO BE USED FOR EM LIGHTING AND EXIT SIGNS.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30951	10041-20000-25594	10100 W SANTA MONICA BLVD 24TH FL	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	04/14/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	Installing additional lighting in office area. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30952	15041-10000-17418	9007 N WOODMAN AVE	91402	6	195B153   291	2639033006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM			PC Info Complete	07/28/2015 12:00:00 AM	PIN	34.23281976	-118.43942219	PC FOR POWER AND ENERGY. FIRST TIME TENANT. MENCHIE'S. TOTAL AREA 1906 SQ FT.B# 15016-10000-09915	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30953	15041-20000-18921	451 S MAIN ST 2nd Floor	90013	14	129A211   281	5149022***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.04711	-118.24844	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 6,491 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30954	19041-20001-22803	425 W 14TH ST	90731	15	012B201   144	7456016011	R2-1XL-CPIO	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.73135	-118.28632	08-16-2019 Changes to an approved set of plan, changes include increase inverter size to 3.8KW, PV system size: 4.62KW 14 PV modulesFees  $82.02 due to California senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30955	13041-20000-17983	14059 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.14947	-118.43889	PLAN CHECK FOR POWER AND ENERGY FOR NEW WELLS FARGO. 3990 SQRFT.This approved set to be referenced for most up to date calculated load on MSB.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30956	15041-10001-39805	30 N LATIMER ROAD	90402	11	126B133     2	4409013013	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.04484	-118.51179	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2. PROVIDED ADDITIONAL PANEL SQ1 TO POWER SERVANT'S QUATERS. LOADS HAVE BEEN RELOCATED. PLAN CHECKING FOR NEW PANEL. PERMIT ALREADY ISSUED UNDER BUILDING COMBO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30957	13041-10000-00113	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM			PC Approved	01/03/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	T.I.  Title 24 plan check for the first floor lobby and the fourth floor cafeteria.  Project is part of the the the projects that were plan checked under 12041-10000-07193 and 12041-10000-18381.  This is the 3rd phase of the entire project.  Plan check is for energy only and emergency lights.  This application was generated for fee purposes,  Double check fees and scope of work once applicant is ready to submitt for plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30958	17041-10000-45829	6520 S CRENSHAW BLVD	90043	8	105B185  1311	4006015017	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	33.9801	-118.33066	T-24 PC FOR ENERGY ONLY. CHANGE USE OF TENANT SPACE FROM RETAIL TO TAKE-OUT PIZZA RESTAURANT.TOTAL AREA AFFECTED IS 1080 SQ FTSCOPE INCLUDES NEW LIGHTS AND RECEPTICALS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30959	18041-20000-34197	21000 W PLUMMER ST BLDGS-A&B	91311	12	198B109    41	2746008014	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.24253	-118.59179	ti to existing sleeping quarters in a commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30960	15041-10000-43403	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.03365	-118.24048	Full plan check for retail spaces at first level of a parking structure, owner build out. Newly connected load is less than 400 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30961	18041-20000-47039	4513 N TOBIAS AVE	91403	4	168A149   195	2265004015	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Issued	12/28/2018 12:00:00 AM	ADDRESS	34.15355	-118.45214	Plan check for PV roof mounted system, system size: 14.45kW, 13.127kW AC CECwith 49 PV modules and 1 inverter(11.4kW)Note: Permit Fess $44.09 due to CA Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30962	18041-10000-40633	13363 W JAVA DR	90210	5	159B157   240	4385004017	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Expired	09/05/2023 12:00:00 AM	ADDRESS	34.12923	-118.42434	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 24 MODULES (LG LG320N1K-A5) AND 24 MICROINVERTERS (ENPHASE IQ6-60-2-US).  SYSTEM SIZE IS 7.92KWdc and 5.76KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30963	17041-10000-09908	200 S SAN PEDRO ST 310	90012	14	129A213    85	5161022023	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.04904	-118.24164	RESTAURANT TI. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30964	10041-20000-25536	5445 N LANKERSHIM BLVD 1st Floor	91601	4	174B173  1290	2350012034	C2-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	01/25/2011 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.16968	-118.37785	Install new 1200 amp switchboard, panels, and branch circuits.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30965	16041-10000-41225	14024 W COMMUNITY ST	91402	6	192B153   690	2638037018	R1-1, RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.22248	-118.43862	PC for title 24, outdoor lighting. Remove HID fixtures and replace with new LED fixutures. Totalsqft = 34525	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30966	17041-20000-24626	17319 W ROSCOE BLVD	91325	12	192B133   237	2787020030	P-1VL, QC2-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Closed	02/23/2018 12:00:00 AM	ADDRESS	34.22126	-118.51063	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL. 1370 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30967	18041-10000-17361	7655 N HASKELL AVE	91406	6	186B141    26	2206011011	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.2098	-118.47518	REPLACE INDOOR / OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30968	13041-10000-28973	11881 W BRAY ST	90230	11	108B161   872	4218018043	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	33.98938	-118.40769	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A 2-STORY HOUSE. INTERCONNECTING WITH NEW 200A MAIN SERVICE. (12) SOLAREDGE POWER OPTIMIZERS #OP250-LV-MC4SM-2NA-Z, WITH (12) TRINA SOLAR #TSM-250PA05.18 MODULES, (1) SOLAREDGE #SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
30969	16041-20001-05911	758 E 21ST ST	90011	9	121-5A209 338	5131012006	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	34.02529	-118.25773	Expedite per applicant request. {{{{{{Plan check for PV roof mounted system. System size: 6.24kW with  24 modules and 24 microinverters Enphase M-215-6002LL-S2X-IG.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30970	13041-10001-26257	18241 W SYLVAN ST	91335	3	177B125    28	2124018050	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.18545	-118.53093	)))) CHANGES MADE TO AN APPROVED PLAN TO ADD AN 125A LOAD CENTER TO ACCOUNT FOR THE RELOCATED LOAD. $0 PERMIT FEE DUE TO 2012 SENATE BILL 1222 (((((((((((((((((  $0 PERMIT FEE DUE TO 2012 SENATE BILL 1222. PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200A MAIN IN A 2-STORY HOUSE. WORK IS DONE ON A CENTRAL INVERTER SYSTEM, STANDARD PLAN. SYSTEM SIZE IS 10.5 KWDC WITH (42) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG PLUS V 7.5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30971	16041-20000-28736	500 W WORLD WAY NORT TRML 5	90045	11	087B165    13	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	PIN	33.9331766	-118.39750919	TI TO AN EXISTING COMMERCIAL SPACE (KIOSK).  NEW LIGHITNG NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 63.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30972	13041-20000-17544	6600 N VAN NUYS BLVD	91405	6	180B149   420	2237001017	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			Reviewed by Supervisor	07/22/2013 12:00:00 AM	ADDRESS	34.19081	-118.44843	Plan check for power and energy. TI to laundromat. New 1200A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30973	18041-30000-02561	200 WORLD WAY T2Northern-Gates	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for power only. Install new 1200 A distribution board for new gates LAX (Passanger Boarding Bridge PBB 400Hz) Ternal 2 Northern Gates. Delat Sky Way	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30974	18041-20000-03864	20272 W JUBILEE WAY	91326	12	213B113   390	2701087026	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.28331	-118.57576	Plan check for the installation of (6) Tesla PowerWalls onto a 400-amp service for a single-family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30975	17041-20000-04761	13439 W OSBORNE ST #6	91331	6	198B157   125	2621028022	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.24251	-118.42586	ti to an existing commercial space.  adding new lighitng new controls to existing panels.  plan check for enegy only.  total square footage 1432.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30976	19041-20000-42257	6200 N VARIEL AVE	91367	3	177B109     7	2149004007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			10/17/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.18341	-118.59258	"10-17-2019 Changes to an approved set of plans, lighting plan revisions and single line diagram reconfiguration.  All changes clouded under delta ""F"".  Original permit issued under 16041-20000-21721."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30977	16041-10000-08238	4506 S INGLEWOOD BLVD	90230	11	108B161   172	4218007024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM			PC Approved	03/09/2016 12:00:00 AM	ADDRESS	33.9948	-118.4174	T-24, CHANGE OF USE FROM A BAKERY TO A TAK E OUT RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 780. refer to permit 16041-30000-19167 for installation of equipment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30978	15041-20001-41528	11553 N BABBITT AVE	91344	12	213B133   470	2607007035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM			PC Approved	02/08/2016 12:00:00 AM	ADDRESS	34.28092	-118.50834	Change of inverter model to 3.8 kW rated model and change of module-string configuration.  (((PV1.  Install 3.99 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.  (14) SolarWorld SW285 Mono panels w/ SB-5000TL transformerless inverter.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30979	17041-10000-39219	8353 N SEPULVEDA BLVD	91343	6	192B145   327	2654027009	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.22295	-118.46791	PC for T24 only for replacement of HID fixtures with LED fixtures. Total 43100sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30980	17041-10000-38907	9375 N SAN FERNANDO ROAD	91352	6	198B165    81	2629009031	C2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.23936	-118.39413	T-24, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES THE LIGHTING REMODEL OF BATHROOMS IN A CVS RETAIL. TOTAL SQ. FT. 73.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30981	16041-10005-16012	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	PIN	34.04222127	-118.45848597	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES ARE CLOUDED UNDER DELTA #7 ONLY - CHANGES INCLUDE ADDITION OF NEW CIRCUITS, AND RELOCATION OF EXISTING CIRCUITSNEW MIXED USED APARTMENT BUILDING 147 UNIT 5 STORIE .PLAN CHECK FOR POWER AND ENERGY. 12 TYPICAL UNITS, 6 LOFTS AND 3 LIVEWORK UNITS. WITH TOTAL AREA OF 1927884 SQFT. NOTE FIRE ALARM VARIANCE IS FILLED TOGETHER. BUILDING APPLICATION NUMBER 14041-10000-03747.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30982	18041-10000-32574	1360 S FIGUEROA ST # D	90015	14	126A205    86	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.03896	-118.26891	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. RETAIL . UPS STORE. 998 SQFT. SUITE B. building permit #18016-10000-14056	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30983	16041-20001-18550	19333 W SANTA RITA ST	91356	3	171B117    96	2163004011	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM			Reviewed by Supervisor	06/02/2016 12:00:00 AM	ADDRESS	34.16778	-118.5546	Expedited per applicant request.PV1Install photovoltaic roofing shingles on a SFD. Interconnect with a 200A MSP.System size: 4kW. Ungrounded system. (208) 23W sunslate roofing shingles.Resubmittal of plans - original submittal under 15041-20000-14421.  Zoning clearance previously obtained under building permit application 15016-20000-12346	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30984	11041-10000-08623	2530 E CINCINNATI ST	90033	14	129A225   348	5177033030	R3-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.04626	-118.20433	BRAND NEW FIRE ALARM SYSTEM IN THE BOYS AND GIRLS CLUB.  RED-LINES ON DRAWING ARE FROM ARCHITECT-DESIGNER.  PLANS WERE APPROVED AND STAMPED BY LAFD WITH RED-LINES AS SHOWN, PER CUSTOMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30985	17041-10000-43487	1813 N AVENUE 53	90042	14	157-5A227 286	5479016020	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.12502	-118.19932	Plan check for PV roof mounted system with battery back up system. Total system size: 6.5kW with 20 modules and 1 inverter(6.0kW) and 5.0KW Tesla battery. $0 fees due to Sennete Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30986	16041-10000-32653	3410 W 3RD ST	90020	13	135B197   183	5501024028	(Q)P-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.06884	-118.29027	Plan check for Title 24 only new Starbucks kiosk inside market. Total area: 280  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30987	14041-20000-13786	20630 W NORDHOFF ST	91311	3	195B109    49	2780001039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.23282	-118.58205	New distribution equipment and machinery in (E) manufacturing building.  Install some subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30988	10041-10000-05693	3601 S TROUSDALE PKWY	90089	8	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Issued	05/07/2010 12:00:00 AM	ADDRESS	34.02017	-118.28558	T-24 and emergency lighting in corridors and stairwells on various floors of the building.  Less than 400 amperes of load added.  Called Phase 2 on the plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30989	16041-10000-42752	17326 W TRAMONTO DR 1-8-Bldg 4	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	01/06/2022 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building 4 story 8 units (Type A) with 1 service 2500A  feeding all 9 Buildings. Performance method is being use for Title 24. Total area: 14,623 sq ft. (400A distribution board for building)Note: This is 9 buildings submit  in 1 plan. 4 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30990	16041-10001-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA ADD_08. CHANGES INCLUDE MODIFY CIRCUITRY TO AS BUILT. REMOVE SCOPE OF WORK. REDUCTION OF CIRCUITS AND REDUCTION OF PANELS. PROVIDED NEW FLOOR PLANS AND UPDATED T24. NO ADDITIONAL PERMIT ITEMS TO BE CHARGED, THIS IS PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30991	17041-20000-30854	521 N ROCKINGHAM AVE	90049	11	135B137   472	4406004001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			Verifications in Progress	10/24/2017 12:00:00 AM	ADDRESS	34.06464	-118.49068	Plan check for solar pv system with AC coupled battery backup system.Derating main breaker from 600A to 500A.(55) EnPhase M250 microinverters [13.2kW].(55) 320W pv modules.(4) 5kW Tesla Powerwall 2s.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
30992	11041-10000-18952	710 N FRONT ST	90731	15	021B201    13	7440025904	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro, Wilmington		2962.10	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	33.7518	-118.28623	NEW SERVICE, PANELS, FOR POWERING DOCKED SHIPS, OUTDOOR LIGHTING, AND POWER FOR A FUTURE BUILDING AT THE HARBOR.  (BERTH 100 WARF)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
30993	16041-40000-41774	5139 N ALLENTOWN PL	91364	3	171B113   353	2166002011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.1636	-118.57304	PV1, AN ADDITON OF A NEW PV SYSTEM TO AN EXISTING SYSTEM.  ADDING 5.886 KW AC TO AN EXISTING 6.00 KW AC SOLAR SYSTEM ON A SINGLE FAMILY HOME. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS 11.886KWac.(18 ) AC MODULES: SPR-E20-327-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
30994	18041-10003-18140	7919 S CROYDON AVE	90045	11	099B165   707	4107005032	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM	ADDRESS	33.96609	-118.39262	[[11/2/18 CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA 1 CHANGES. UPGRADING MAIN SERVICE PANEL AND REDUCING SUBPANEL]]]]New rooftop solar system on SFD, (32) modules with (32) power optimizers, (1) 7.6 kW inverter, (1) 13.5 kWh ESS, (1) 200A load center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30995	14041-20002-01488	10410 N JELLICO AVE	91344	12	207B129  1035	2733012035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.25996	-118.51853	Modification to approved set.  Relocation of service panel and corresponding removal of AC disconnect, rerouting of conduit.  Relocation of panel under separate permit.  Note: Plan check fee is $0.00 due to Senate Bill 1222 from 2012.  (((PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30996	15041-20000-03581	21650 W OXNARD ST 7TH FLR	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING, NEW CONTROLS.  USING EXISTING CIRCUITS AND EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1373.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30997	11041-10001-14809	6222 W MANCHESTER AVE	90045	11	096B165   561	4123003019	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM			PC Info Complete	02/29/2012 12:00:00 AM	ADDRESS	33.95969	-118.39442	TENANT IMPROVEMENT OF MEDICAL FACILITY FOR AN INTERNAL MEDICAL PRACTICE.  PLAN CHECK IS FOR POWER AND ENERGY. ((((( 2/29/2012      INSPECTOR REQUESTED TO REMOVE FIRE ALARM NOTES FROM FIRST PAGE OF PLANS.  PLANS WERE CROSS-REFERENCED WITH ORIGINAL APPROVED SET AND ARE RESTAMPED. )))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30998	13041-10002-33183	250 S ROSSMORE AVE	90004	4	135B185    14	5515013001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.06991	-118.32716	"Change to approved set by adding (1) transformer, (1) panel and circuits to the floor plan; All changes are under delta-5 only.(((plan check for power and energy. NEW BUILDING ON CAMPUS OF A PRIVATE GIRLS HS (NEW 129'-4"" x 157'-8""1 story AQUATICS PAVILION BUILDING WITH BASEMENT STORAGE AND ATHLETICS FITNESS ROOMS). methane zone. Also LARGER SURFACE PARKING LOT, A NEW GARDEN AREA, A FULL-SIZE SYNTHETIC TURF SOCCER FIELD, AND 3 NEW TENNIS COURTS. Changes on plan include battery on exit sign to also be fed by inverter and panel FP bus is 125A. Pool panel ACPL installed but loads to be added under separate permit.Fire alarm variance  filed on 8/20/2014)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
30999	17041-10000-24149	704 W 51ST ST	90037	9	111A201   387	5001031005	RD2-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	33.9963	-118.28571	PC FOR ENERGY STORAGE SYSTEM. EXISTING SOLAR ON SITE. INSTALLING POWERWALL WITH BACKUP GATEWAY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31000	11041-10000-01283	21490 W VICTORY BLVD	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.18794	-118.59879	"TI IN AN EXISTING ""NORDSTORM"" RETAIL STORE.  <<<<<<<Fire Life Safety System Under a Different Permit>>>>>>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31001	13041-10000-13259	140 W ANAHEIM ST	90744	15	030B205   411	7423002042	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM			PC Approved	07/29/2013 12:00:00 AM	ADDRESS	33.77972	-118.26333	60' X 35' PORTION OF (E) 56' X 60' TENANT SPACE; CHANGE OF USE FROM RETAIL TO CHASE BANK. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31002	15041-10001-42427	101 N ROBERTSON BLVD	90048	5	138B169   353	4334001012	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	34.07543	-118.3839	03/11/16Changes to an approved set of plans. All changes are clouded under delta 1. Scope includes relocating/adding recessed LED fixtures. (((T-24, TI TO AN (E) COMMERCIAL BUILDING, SCOPE OF WORK INCLUDES NEW LIGHTING TO INDOOR AND OUTDOOR SPACES. TOTAL SQ. FT. 3968.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31003	18041-20000-32153	6300 N CANOGA AVE 1310,1320-1330	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.18492	-118.59722	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31004	17041-10002-33868	3214 W 75TH ST	90043	8	102B185  1182	4012013010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	33.97169	-118.32924	Changes to an approved set of plans. Changes include adding an AC disconnect adjacent to the AC power wall on the single line diagram and on the roof-layout. All changes are under delta F. Note: Permit is paid under PCIS#17041-10000-33868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31005	18041-10000-13743	11111 W SANTA MONICA BLVD 18TH FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC FOR INTERIOR RESTROOM REMODEL AND UPGRADE FOR T-24 ENERGY ONLY IN A HIGH RISE.TOTAL AFFECTED AREA 1530 SQ.FT SCOPE INCLUDES NEW LIGHTS, CIRCUITS AND RECPTACLES.b#18016-10000-11128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31006	17041-20000-30883	10520 N COMMERCE AVE	91042	7	207B197  1399	2566007007	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.26	-118.28839	PV1.  Install 12.42 kW DC/11.52 kW AC roof mounted grid tied PV system.  (36) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31007	19041-20000-44043	5743 N RHODES AVE	91607	2	174B165   332	2340017036	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.17507	-118.40322	PV1. INSTALL 8.03 KW DC SYSTEM WITH (22) MODULES/MICROINVERTERS (ENPHASE IQ6 PLUS)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31008	10041-20000-04515	1901 S AVENUE OF THE STARS # 700	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM	03/17/2010 12:00:00 AM		Permit Finaled	07/08/2010 12:00:00 AM	ADDRESS	34.05949	-118.41705	TENANT IMPROVEMENT.  NEW INTERIOR NON-BEARING PARTITIONS, CEILING, MILWORK AND FINISHES.  Rearranging lighting in some of the office spaces. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31009	13041-10000-29544	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.03497	-118.45709	Installation of a new fire alarm system and to provide 24-hour system monitoring to sprinkler system.  Single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31010	19041-10000-13327	5820 N CANOGA AVE # 300	91367	3	174B105    78	2149019009	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.17555	-118.59717	TENANT IMPROVEMENT FOR OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CIRCUIT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31011	17041-10000-09290	10750 W OHIO AVE	90024	5	132B153   758	4325029018	[Q]RD1.5-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.05597	-118.43737	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 18190 SQ FT. INDOOR/OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31012	12041-10000-24184	10149 N DONNA AVE	91324	12	204B121   277	2729002015	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.2552	-118.54821	Install 10.56 kw roof mounted PV for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31013	12041-20000-17418	9716 N WOODMAN AVE	91331	6	201B149   422	2644024027	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			No Progress	08/06/2012 12:00:00 AM	ADDRESS	34.24675	-118.44773	Install new general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-18319	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31014	16041-10000-00395	600 WORLD WAY Term. 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (LAX ELEVATOR). SCOPE INCLUDES ADDING A NEW LIGHT FIXTURE TO THE ELEVATOR CONTROL ROOM. TOTAL AFFECTED AREA IS 60SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31015	13041-20001-23803	22017 W BUENAVENTURA ST	91364	3	168B101   667	2170014006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/07/2013 12:00:00 AM	ADDRESS	34.15533	-118.60652	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. 22 MODULES AND 1 INVERTER. 5.0 KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31016	13041-10001-31881	545 W 130TH ST	90061	15	081B201   292	6132003019	M2-1VL-O, P-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	33.91464	-118.28459	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31017	19041-20000-16690	22135 W ROSCOE BLVD LOT #2	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	Plan check for PV roof mounted system, system size: 2.1KW with 7 PV Modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31018	18041-20000-49189	13153 W TONOPAH ST	91331	6	195B161   665	2627022005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.22755	-118.41922	Plan check for PV roof mounted system, system size: 4.93kW DC, 5.0kW AC with 17 PV Modules and 1 inverter(5.0kW) center fed.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31019	13041-20000-29135	416 N CITRUS AVE	90036	5	141B185  1154	5524031010	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM	10/24/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.07882	-118.33956	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 26 MODULES. STRING COMBINER. PC REQUIRED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31020	13041-20000-00997	333 S HOPE ST 26th floor-27th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM			PC Approved	01/15/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for energy and emergency lighting. 26th and 27th floor (7276sqft and 6315 sqft).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31021	19041-20000-25634	915 W WILSHIRE BLVD 7TH FL-8TH FL	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	04/10/2020 12:00:00 AM	ADDRESS	34.05069	-118.2599	Tenant improvement on 7th and 8th floor of existing office high-rise building, newly connected load in excess of 400A. Total area: 35,420 sq ft. B#19016-100000-17777	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31022	19041-10000-22403	701 W CESAR E CHAVEZ AVE #101	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural North		2071.01	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	07/09/2020 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.06107	-118.24412	PC (power and Energy) , change of use of retail space . Scope of work to include (N) 600A feeder @ 208/120V, 3ph,4W. area scope of work is 2,210SF (building permit#18014-10000-03279)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31023	18041-30000-19762	180 N ALEXANDRIA AVE	90004	13	138B197   551	5518012038	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2112.01	Electrical	Electrical	Apartment			05/29/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Issued	05/29/2018 12:00:00 AM	ADDRESS	34.07507	-118.29828	New Fire alarm system for 4-story apartment building. (1) FACP, (47) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31024	16041-10000-38579	125 W 5TH ST	90013	14	129A211   281	5149022***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.0471	-118.24893	Title 24 plan check.  Change of use from retail to coffee shop.  New 75 kVA transformer and 200 amp panel with associated lighting and receptacle loads.  Total area = 994 sq. ft.Building permit #16016-10000-12077	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31025	13041-20000-11225	970 N MONUMENT ST #103	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/06/2013 12:00:00 AM	ADDRESS	34.04646	-118.52393	Change to lighting only in suite 103, in an existing low-rise retail space.  Load is less than 400 amps per applicant. PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31026	18041-20000-16982	10707 W BURBANK BLVD	91601	2	174B177   554	2415019020	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.17232	-118.36408	Plan check for fire alarm system for office building Total fire alarm: 31 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31027	18041-20001-44056	16801 W LASSEN ST	91343	12	201B137   146	2685012022	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM	01/11/2019 12:00:00 AM		Issued	01/11/2019 12:00:00 AM	ADDRESS	34.25037	-118.49805	01-11-2019 Changes to an approved set of plan, Changes include change PV System to central inverter, 2 inverters(7.6KW and 10.0KW) and 45 PV Modules, System size: 17.78KW DC, 17.6KW AC Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31028	14041-10001-24754	380 WORLD WAY Space 88	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to approved set.  PC at request of inspector.  Change of location of timeclock override switch and removal of dimming from title 24 sheet.*****Previous Work Description*****Title 24 plan check only.  Total area = 46 sq. ft.T.I. to airport terminal kiosk.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31029	13041-20000-20392	13010 W HAGAR ST	91342	7	222B161   411	2525026018	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.30266	-118.41626	New Ungrounded PV System for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31030	14041-20001-14002	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM			PC Approved	10/07/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	SUPPLEMENTAL TO REMOVE AND REPLACE LIGHTING FIXTURES ON BUILDING NO. 4PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. RIOT HEADQUARTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31031	16041-10000-16503	225 N VERMONT AVE	90004	13	138B197   568	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			05/11/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.07529	-118.29188	Install NEW FIRE ALARM system on (N)  4-story mixed-use apartment, 1 underground parking (METHANE ZONE).  (1) FA panel   (1) Comm. Panel    (256) Devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31032	18041-20000-25031	1670 W BEVERLY BLVD 1nd Floor-STE 4	90026	13	135A207   236	5153012023	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.06416	-118.26523	First-time tenant to 1ST-floor commercial office space.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31033	18041-10000-14335	2626 W COLORADO BLVD	90041	14	163-5A219 162	5682002024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	06/23/2022 12:00:00 AM	ADDRESS	34.14192	-118.22342	NOTE: FEES ARE $0 DUE TO AB 1414(((PC FOR NEW COMMERCIAL ROOF MOUNTED (ON A TARGET STORE) 3PHASE PV SYSTEM. SCOPE INCLUDES 840 MODULES AND 6 INVERTERS. TOTAL SYSTEM SIZE 323KW.AC AND A 365.4 KW.DC B#18016-10000-12055	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31034	18041-10000-48184	16009 W ACRE ST	91343	12	195B141   524	2672021002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.23029	-118.48107	PLAN CHECK FOR ROOF MOUNTED 5.0KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) WITH 18 MODULES USING P320 OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31035	11041-10000-21943	777 S FIGUEROA ST 825	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.04828	-118.26116	Tenant remodel of suite 825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31036	16041-30000-37885	986 S VERMONT AVE	90006	10	129B197   207	5076001034	C2-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.05277	-118.29141	Title 24 plan check.  T.I. to existing El Pollo Loco restaraunt.  Changes to lighting including upgrade to LED fixtures.  Emergency bugeyes and exit signs to remain in place.  Total area = 1,380 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31037	14041-10000-06883	108 E 5TH ST 1-69	90013	14	129A211   194	5148019011	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Public Safety Only			03/14/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Closed	03/18/2015 12:00:00 AM	ADDRESS	34.04636	-118.2484	New fire alarm system for 5 story Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31038	15041-10000-12246	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	PIN	33.93847109	-118.41935625	TI FOR TITLE 24 TO AN (E) OFFICE SPACE FOR 3 FLOORS. PC FOR ENERGY. TOTAL SQ. FT. 11386.ALL LIGHTING CIRCUITS ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31039	17041-10000-10100	20123 W SATICOY ST	91306	3	186B113   173	2114004045	(Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.20849	-118.57191	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT SPACE. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 1170 SQ. FT.  b#17016-10000-07553	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31040	18041-10000-09791	10940 W WILSHIRE BLVD 1525	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.05822	-118.4452	PLAN CHECK FOR TITLE 24 ONLY FOR - NON-STRUCTURAL TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. TOTAL AFFECTED AREA = 1315 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31041	16041-10005-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS. ADDITION OF 1 luminaire and 25 sq.ft to total affected area  PC FOR CHANGES NOTED DELTA DCN-027 (same delta as 10004)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31042	17041-10000-40009	801 S BROADWAY	90014	14	127-5A209 109	5144017030	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Issued	12/04/2017 12:00:00 AM	ADDRESS	34.04375	-118.25498	DESIGN BUILD, PC for T24 only for facade lighting in a 9 story building with upper level penthouse. Total illuminated area is 175285 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31043	14041-10000-15560	12303 W MONTAGUE ST	91331	7	204B165   175	2537005016	M2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.2551	-118.40128	T.I. for existing 1 story office building w/ mezzanine floor.  Power and lighting plan check.  Total area = 57,800 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31044	19041-20000-48135	7847 W WENTWORTH ST	91040	7	208-5A195  70	2552018018	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.26711	-118.30433	PLAN CHECK FOR 2 ENERGY  STORAGE SYSTEM(ESS). SCOPE OF WORK CONSISTS OF NEW PANEL AND BATTERY POWER WALL 2.0. ESS SIZE: 13.5KWH. PV(7.56KW) PERMIT PAID AND PULLED UNDER 19041-90000-48135	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31045	14041-10000-28938	10979 W BLUFFSIDE DR BLDG 1	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	Note to plan check engineer: applicant returns and swaps new plan with additional circuits added on after orignial fee was paid. Plan check engineer need to verify the fee per F.Y(((Installing new washer/dryers and booster fans in apartment units.  Bldg 1 of 6.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31046	15041-10000-09838	12770 W CASWELL AVE 1-11	90066	11	111B153  1140	4236019015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			04/02/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	33.99766	-118.43804	INSTALL NEW FIRE A;ARM SYSTEM FOR 4 LEVEL 3 STORY, 11 UNITS APARTMENT BUILDING. 74 FA DEVICES AND 1 CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31047	15041-20000-25405	10428 W NATIONAL BLVD 1/2	90034	5	120B161    86	4314022037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.02872	-118.41132	Plan check for Title 24 only in two bathrooms. Total area: 100 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31048	18041-10001-41844	333 S HOPE ST 23rd	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM			PC Info Complete	02/20/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	SUPPLEMENTAL PC FOR DELTA 3 CHANGES TO AN APPROVED SET. CHANGES RECEPTACLES, CONTROLS AND LIGHTING. CHANGES TO T-24 FIXTURE COUNTS FOR F3-W, F6 AND F8<<<<<Original Scope of Work>>>>>>>>FULL PLAN CHECK FOR POWER AND ENERGY FOR OFFICE T.I. 23rd floor ONLY. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING . TOTAL EFFECTED AREA 21282 SQFT. NEW CONNECTED LOAD OVER 400AMPS.BLD# 18016-10000-35366	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31049	17041-20000-08013	5215 N LUBAO AVE	91364	3	171B113   191	2164005013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.16548	-118.56708	Plan check for a PV1 roof-mounted PV system. System size is 14.5 kWac and consists of (42) AC modules and (1) load center.$7.47 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31050	15041-10002-29680	205 E ADAMS BLVD	90011	9	120A207    46	5127037011	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.02435	-118.26718	[PC only] Revision on approved set: Remove meter from single-line per field installation. Permit under 15041-10000-29680 <<PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31051	15041-10000-21006	332 W FLORENCE AVE	90003	9	102B201   898	6031003028	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	33.97451	-118.27948	T-24, PC FOR ENERGY ONLY. REMOVING HID LIGHT FIXTURES AND REPLACING WITH LED LIGHT FIXTURES. TOTAL SQ. FT. 5346	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31052	12041-20000-20340	19960 W VENTURA BLVD	91364	3	174B113   434	2164001041	(Q)C4-1VL, (Q)C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	34.17182	-118.56787	Remodel of an existing restaurant, changeing lighting, receptacles, and equipment.  Load is 221 Amps.  Occupancy load is 80, per architect.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31053	16041-20001-45146	3201 S COLBY AVE	90066	11	120B153  1197	4250018018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2016 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.02153	-118.43273	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (37) modules. Standard plan is being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31054	17041-10000-08368	14006 W RIVERSIDE DR #122	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	Nekter juice bar TI. New lighting. PC for T24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31055	11041-20000-14768	3740 S MCCLINTOCK AVE EEB #219	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Closed	07/08/2014 12:00:00 AM	ADDRESS	34.01972	-118.29033	Ti in Hughes Aircraft EE Center. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31056	14041-10000-33116	6381 W HOLLYWOOD BLVD	90028	13	148-5A187 157	5546005010	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.10177	-118.32913	Change of use from bank to night club. Total area 7125 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31057	10041-10000-10871	2165 W VENICE BLVD	90006	1	126B193   285	5074009022	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Expired	11/19/2012 12:00:00 AM	ADDRESS	34.04372	-118.30475	New PV system for a church	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31058	19041-20000-34585	520 E MANCHESTER AVE #4	90003	9	097-5A207 324	6041019003	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	33.95996	-118.26583	Power and lighting for dental office TI.  Plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31059	15041-10000-43025	964 S BERENDO ST PHASE 1	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.05378	-118.29358	12/21/15FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY BAPTIST CHURCH AND PRIVATE SCHOOL OVER ONE LEVEL OF SUBTER. PARKING GARAGE. NEW UNDERGRND SERVICE 2500A,480/277, 3-PHASE. TOTAL AREA (UNCONDITION + CONDITIONED) FOR ENERGY IS 229958 SQ FT. NONE METHANE ZONE ON ZIMAS*PROJECT WILL BE SPLIT INTO TWO PHASES. PHASE 1 OF 2. CHANGES INCLUDES THE PARKING STRUCTURE AND 1ST FLOOR OF THE CHURCH AND SCHOOL. *Note 1/25/16: The building under this project covers addresses as follow (APN to all is 5078008034):964 S. Berendo St., 979 S. New Hampsire Ave., 979 1/2 S. New Hampsire Ave., 981 S. New Hampsire Ave.***PER APPLICANTS REQUEST NO CHANGES DONE FROM ORIGINAL TO NEW APPLICATION. BLDG PERMIT UNDER 12010-10002-02799)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31060	15041-10000-18741	12415 N SAN FERNANDO ROAD	91342	7	219B149   666	2611007035	(T)(Q)C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.29585	-118.45528	PC FOR POWER AND ENERGY.  FOUR STORY ,101-UNIT APARTMENT 3000A SERVICE. TOTAL AREA 66,779 SQ FT(INDOOR) PLUS 11672 SQ(OUTDOOR).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31061	19041-20000-30333	13642 N GLADSTONE AVE	91342	7	228B153   396	2503006005	A1-1-K, RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.31994	-118.43984	PV1. SYSTEM SIZE OF 11.88 KWDC AND 9KWAC. INSTALL (36) LG330N1C PANELS WITH (1) INVERTER (SOLIS-1P9K-4G-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31062	18041-10000-30249	1411 E WALNUT ST	90011	9	120A211   264	5129006030	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.02226	-118.24813	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31063	14041-10000-31277	10206 N MOUNTAIR AVE	91042	7	204B197   948	2558021012	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.25442	-118.29306	New fire alarm system with (58) devices and (1) Panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31064	15041-20001-20050	16852 W BAHAMA ST	91343	12	195B133   156	2688027013	RA-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.23298	-118.49991	Supplemental application for expedite fees only.  Addition of inverter and solar panels to existing roof mounted solar PV array.  Total system size = 11.6 kWac.  Three inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31065	19041-10000-14062	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	PIN	33.92817449	-118.43220714	AT THE HYPERION TREATMENT PLANT,  DISCONECT AND REMOVE MOTORS # 6, # 11, #12 AND THEIR FEEDERS ; REPLACING 9 EACH 480V 50HP MOTORS WITH 9 EACH 480V 40HP  AND 9EA 4160V 300HP MOTORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31066	16041-20000-08166	9714 W LA TUNA CANYON ROAD	91352	7	195B181    40	2401038011	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.2351	-118.34252	Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter and (34) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31067	14041-20000-03400	1150 W JEFFERSON BLVD	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Issued	03/04/2014 12:00:00 AM	ADDRESS	34.02281	-118.29042	PC FOR POWER AND ENERGY. PC FOR NEW LIGHTING, OUTDOOR. TRENCHING INVOLVES METHANE LOCATION. FULL PLAN CHECK REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31068	10041-20000-25658	2701 W WILSHIRE BLVD	90057	1	133-5A201  58	5141010007	C4-2	Central	Westlake	MacArthur Park	YES	2087.20	Electrical	Electrical	Apartment			12/28/2010 12:00:00 AM			Corrections Issued	02/15/2011 12:00:00 AM	ADDRESS	34.06114	-118.28235	New roof mounted 16.17 KW P.V. system (Bryson Apartment).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31069	18041-10000-17367	206 E 9TH ST	90015	14	126A209    89	5145016001	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Closed	01/11/2023 12:00:00 AM	ADDRESS	34.04049	-118.25412	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31070	16041-10001-22911	7034 N TAMPA AVE	91335	3	183B117   395	2129007007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.19844	-118.55331	PLAN CHECK ONLY FOR PV1 SYSTEM WITH 16 MODULES AND M250 ENPHASE MICRO-INVERTERS. TOTL SYSTEM SIZE = 4KVA Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31071	18041-10000-28637	10425 S LA CIENEGA BLVD	90045	11	090B173   320	4129035019	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.94086	-118.37028	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31072	14041-10000-28282	11800 W FOOTHILL BLVD	91040	7	210B165   540	2528002901	C2-1VL, OS	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails, Pacoima	YES	1041.06	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	PIN	34.27302957	-118.39323555	PC FOR T24 ENERGY.FOR KITCHEN AND STORAGE, BEAN SPROUTS, INSIDE THE (E) MUSEUM. TOTAL 573 SQ FT. EMERGENCY LIGHTING. INCLUDING INDOOOR SIGN LIGHTING.B# 14016-10000-18126	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31073	13041-10000-32288	3718 N CROWNRIDGE DR	91403	5	162B141   370	2280008018	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.13786	-118.47439	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.PV1, Install 15 kW DC roof-mounted solar array, interconnect with service panel. Transformered inverter. Fronius IG Plus A 11.4. 60 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31074	18041-20000-28708	17036 W CALAHAN ST	91325	12	198B133   598	2692019004	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.2363	-118.5038	Plan check for a PV1 roof-mounted PV system. System size is 8.775 kWdc/8.1 kWac-CEC and consists of (2) inverters, (29) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31075	15041-10000-16706	10201 W PICO BLVD B663	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	PIN	34.05182951	-118.41257696	(N) 14-device fire alarm system with FACP in (E) commercial office bungalow building.  Permit issued as owner-builder to LADBS-issued Electrical Maintenance Supervisor license #P027264 (exp. 02/26/2016).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31076	15041-20000-35190	16674 W DEMARET PL	91344	12	216B137   103	2609010004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.29085	-118.49622	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (56) modules, (56) power optimizers, and (1) load center.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31077	11041-20000-22274	20940 W BURBANK BLVD north side	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM			Ready to Issue	10/20/2011 12:00:00 AM	ADDRESS	34.17302	-118.58923	INSTALL FIRE ALARM DEVISES TO EXISITNG SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31078	17041-10000-24160	8247 N RESEDA BLVD	91335	12	192B125   689	2103005066	C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.22044	-118.53629	Remove HID fixtures and replace with new LED fixtures - T 24 only.outdoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31079	14041-10000-12301	800 E 4TH PL	90013	14	127-5A215 140	5163011002	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.04433	-118.23669	TI FOR EXISTING WAREHOUSE. ADDING STORAGE ROOM AND BATHROOM. RENOVATION OF ENTIRE SPACE AND OUTDOOR LIGHTING. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31080	16041-10000-09875	6002 S ALVISO AVE	90043	8	105B181   575	4004021001	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM			PC Info Complete	04/05/2016 12:00:00 AM	ADDRESS	33.98516	-118.34376	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (RETAIL STORE) SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1899 SQ. FT.NOTE: PERMIT FOR PANEL, SERVICE, OUTLETS, AND LIGHTS ARE PAID UNDER: PCIS#16041-70000-02231PCIS#16041-70001-02231	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31081	13041-10000-22952	12525 W HATTERAS ST	91607	2	174B161   154	2341013026	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.17587	-118.40632	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A NON STANDARD PLAN. SYSTEM SIZE IS 7.35 KW DC AND 6 KW AC. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: POWER-ONE # AURORA PVI-6000-OUTD-US]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31082	19041-20000-24156	120 N BENTLEY AVE pv1	90049	5	138B149   115	4366002017	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.07529	-118.45813	permit fee $0.00 by state senate bill no. 1222pv1install roof mounted pv systen sized 15.2KW AC interconnecte dwith msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31083	14041-20000-02615	8109 N CLEMENS AVE	91304	12	189B093    45	2020002006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.21778	-118.63809	pv1 single family dwelling. total system size 4.3kw ac using microinveter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31084	18041-10000-17932	2310 S LA CIENEGA BLVD UNIT #1	90034	10	126B173  1015	5066001005	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.0378	-118.37711	Full plan check for a restaurant T.I. Scope includes new lighting and equipment with a 1200-Amp service. BLD application #: 18016-10000-15307	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31085	17041-20001-09885	12601 W PIERCE ST 45, 46	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 45 and 46).12kW ungrounded system. (24) AP Systems YC500i microinverters. (48) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31086	15041-20001-13858	7919 W MCGROARTY ST	91040	7	204B193  1335	2559025006	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.25229	-118.30548	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 5.25 kWac.  Microinverter system with two branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31087	16041-10000-38591	6759 N SEPULVEDA BLVD	91411	6	180B145   903	2234022013	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/03/2016 12:00:00 AM	ADDRESS	34.19355	-118.46643	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR LIGHTING). TOTAL AREA 6375 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31088	12041-20000-11992	701 N PALISADES DR	90272	11	129B117    26	4416006013	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	9800.19	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.04842	-118.55296	T.I. to existing classrooms (meeting, science, and computer rooms).  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-1193	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31089	19041-20000-33149	4180 N VERDUGO VIEW DR	90065	1	154-5A219 213	5472010028	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.11787	-118.22289	13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31090	16041-10000-06482	4645 N TUJUNGA AVE	91602	2	168B173   791	2354008027	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	04/16/2016 12:00:00 AM	ADDRESS	34.15533	-118.3793	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.400 KW DC..(21)MODULES-HYUNDAI HIS-S260RG(21)MICROINVERTERS-ENPHASE M215-602LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31091	19041-30000-38291	12100 W WILSHIRE BLVD Ste. 1950	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.0438	-118.46755	T-24, Tenant improvement to install new lighting and receptacles, (Suite 1950 and Suite 1955). Total sq. ft. 3155.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31092	16041-10000-10200	9013 N PETIT AVE	91343	12	195B137   100	2688025020	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.23437	-118.49831	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.67KWdc / 5.0KWac. (18)MODULES-LG315N1-G4(1)INVERTER-ABB PVI-5000-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31093	15041-10000-29487	500 WORLD WAY TERMINAL 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	NEW 1200 AMP SWITCHGEAR (BMS-5A) TO BACK FEED TWO EXISTING FEEDERS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31094	18041-20000-19172	3705 N MARFIELD AVE	91356	3	162B121   113	2177043028	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.13698	-118.55053	PV1.  Install 18.2 kW roof mounted grid tied PV system.  (56) modules with (2) 7.6 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31095	18041-10001-04506	5850 S VERMONT AVE	90044	9	105B197    72	6004001024	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Public Safety Only			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Closed	06/26/2018 12:00:00 AM	ADDRESS	33.98773	-118.29129	CHANGE MANUFACTURER OF PANEL AND FA DEVICES FROM KIDDE TO BOSCH((((((((((NEW (BACK BONE)  FIRE ALARM SYSTEM IN A COMMERCIAL BUILDING . IT INCLUDES TWO NOTIFICATION CIRCUITS AND MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31096	14041-10002-02690	12515 W OSPREY LANE	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.97893	-118.41131	Energy plan check for outdoor lighting, 7G per inspector request  ;  the scope of work is 12,100-SQ feet. Permit fee is paied  under permit #: 14041-10000-02690.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31097	11041-10000-14763	9157 N DE SOTO AVE No. B-Starbucks	91311	12	198B109   215	2746009047	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	10/21/2011 12:00:00 AM		Permit Finaled	03/15/2012 12:00:00 AM	ADDRESS	34.23726	-118.5888	RESTAURANT TI FROM SHELL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31098	13041-20000-16455	5815 W SUNSET BLVD BLDG C-STE 210	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM			PC Approved	06/21/2013 12:00:00 AM	ADDRESS	34.09822	-118.31613	Plan check for energy and emergency lighting. Not a first time tenant per applicant. Photoshop. Building C, Suite 210. Kensington	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31099	14041-10001-27773	2645 S LA CIENEGA AVE	90034	10	123B173   670	5065007006	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			PC Approved	01/14/2015 12:00:00 AM	ADDRESS	34.0335	-118.3785	EXPEDITED PER APPLICANTS REQUESTPV 2 system. Roof mounted. Negatively-grounded central-inverter system. 403 modules, 1 inverter, and 1 AC disconnect for a 102,765 kW system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31100	18041-10001-39300	1825 N LAS PALMAS AVE	90028	13	150A185   276	5547001025	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			06/12/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.10476	-118.33652	"Delta ""2""  CHANGES TO APPROVED PLANS TO USE ""SILENT KNIGHT"" ifp-2000"" FIRE ALARM PANEL INSTEAD OF ""MIRCOM"". <<<<Plan check for a fire alarm system for a 6-story, 118 unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (472) devices.>>>>NOTE: PERMIT FEES ARE PAID UNDER PCIS#18041-10000-39300"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31101	18041-10000-47741	5334 N LINDLEY AVE	91316	5	171B125   106	2162003***	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Apartment			12/17/2018 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM	ADDRESS	34.16795	-118.52709	Plan Check for energy only. scope of work includes renovation common areas in an apartment building, new lighting and power. Total sq. ft. 2832.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31102	18041-30000-29164	1131 S BEACON ST	90731	15	015B201   667	7456004006	R3-1XL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Apartment			08/02/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	33.73365	-118.28059	PV2 10kw AC / 12.7KW DC roofmounted solar system with (1) 10kw inverter, (43) modules and optimizer interconnecting through the main service panel.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31103	18041-20000-45261	11701 N ODESSA AVE	91344	12	213B137   144	2610021006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.28325	-118.49133	PV1.  Install 3.05 kW DC roof mounted grid tied PV system.  (10) new modules alongside (6) existing modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31104	19041-20000-39021	17623 W SUNBURST ST	91325	12	195B129    23	2768024025	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.23468	-118.51868	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 9.75 KW DC/8.85 KW AC. SCOPE OF WORK CONSISTS OF (30) PV MODULES WITH MICROINVERTERS, AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31105	19041-20000-34129	10725 N SUTTER AVE	91331	7	207B157  1310	2535030001	M2-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.26491	-118.41977	PLAN CHECK FOR ADDITION OF A SUB PANEL AND 6 MOTORS TO AN EXISTING COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31106	16041-20000-31904	12350 N VILLAR WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29514	-118.45501	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31107	15041-20000-29951	5961 N LAUREL CANYON BLVD	91607	2	177B165   793	2340004029	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	PIN	34.17892385	-118.39694996	Plan check power and energy for retail building (two retail spaces)Note: 2 separate building on the same plan and take in as 1 PCAMNote: Building permit has been issued under 14010-20000-01601	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31108	15041-10001-16779	3006 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	34.02698	-118.4281	CHANGES TO APPROVED SET. LIGHTING TO REMAIN, TITLE 24 ONLY. CHANGE OF SERVICE SET-UP. (((TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2085.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31109	17041-20001-43979	16738 W CALAHAN ST	91343	12	198B137   941	2687019006	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.23652	-118.49713	expeditepv1install roof mounted pv system sized 10.4kw intercomnnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31110	19041-10001-19706	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey, Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Issued	10/24/2019 12:00:00 AM	ADDRESS	33.98095	-118.40764	PC FOR CHAGNGES TO APPROVED SET, SCOPE OF WORK INCLUDES ADDING DEVICES TO AN APPROVED FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31111	13041-20000-12251	19240 W DEARBORN ST	91324	12	198B117   187	2762017034	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.23717	-118.5519	pv1 single family dwelling. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 6.2 KW. USING ENPHASE MICROINVERTER. M215. NONSTANDARD PLAN BACK ROOM PLAN CHECK. TOTAL OF 28 MODULES, NEW SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31112	12041-10000-27048	801 S FIGUEROA ST	90017	9	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	03/04/2013 12:00:00 AM		Issued	03/04/2013 12:00:00 AM	ADDRESS	34.04789	-118.26153	TI ON 22ND AND 23RD FLOOR. HIRISE. BANK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31113	12041-10000-18892	11824 W SOUTH PARK AVE	90066	11	111B157   670	4233012002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2012 12:00:00 AM			Reviewed by Supervisor	08/22/2012 12:00:00 AM	ADDRESS	33.99978	-118.42027	New rooftop photovoltaic rooftop system for an existing single family residence.  6.63kw  System is Un-Grounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31114	16041-10000-45782	380 WORLD WAY conduit-only	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Counduit only,  for new MSC concourse building at LAX.  ((Building permit #16014-10000-02498))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31115	13041-20000-12485	6550 N NEVADA AVE	91303	3	180B101   451	2139018015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.18977	-118.60913	PV1 PHOTOVOLTAIC SYSTEM. TOTAL SYSTEM SIZE 5.5KW. USING TRANSFORMED CENTRAL INVERTER. 3 STRINGS. NO COMBINER, 3 INPUT INVERTER. ROOF MOUNTED, SINGLE FAMILY DWELLING. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31116	13041-10000-25460	380 WORLD WAY 3S4-13	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	TITLE 24 FOR A STORAGE IN TOM BRADLY TERMINAL,  3S4-13,   PERMIT  PULLED ON INTERNET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31117	15041-20000-39559	3796 N WINFORD DR	91356	3	162B117   320	2177042009	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.1383	-118.55281	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13,407KWdc/10,000KWac.(41) SUNPOWER SPR-327NE-WHT-D (41)SOLAR EDGE P400 POWER OPTIMIZERS(1) SOLAR EDGE SE10,000A-US 240V INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31118	17041-10000-13062	4634 N DENNY AVE	91602	4	168B177   821	2421021013	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1255.02	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.15495	-118.36466	PC for a PV1 roof mounted solar system, single family home. Installing a central inverter rated at 3.8 KW and a string with 16 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31119	16041-20001-44264	5406 N CALVIN AVE	91356	3	174B117   648	2163003052	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.16904	-118.55617	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (39) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31120	15041-20000-39688	400 S HOPE ST 10TH FLR	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Expired	12/27/2017 12:00:00 AM	ADDRESS	34.05199	-118.25366	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (CORRIDOR, LOBBY, RESTROOM SPACE). SCOPE INCLUDES ADDING NEW LIGHTING TO CORRIDORS, ELEVATOR LOBBY, AND RESTROOMS ON THE 10TH FLOOR. TOTAL AREA IS 3151 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31121	17041-10001-04622	20059 W RINALDI ST BLDG C1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	07/21/2020 12:00:00 AM	ADDRESS	34.2756	-118.57118	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 3. CHANGES INCLUDE ADDING SITE LIGHTING, REPLACING EXTERIOR LIGHTS, AND ADDING TRASH COMPACTOR TO PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31122	19041-10000-35125	420 N LECOUVREUR AVE	90744	15	030B209   898	7424005032	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.77523	-118.25536	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY- (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31123	15041-10001-07110	335 N MARIPOSA AVE	90004	13	138B197   132	5520025012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.07733	-118.29968	EXPEDITED EXPRESS PERMIT PER APPLLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31124	16041-10000-32679	825 N MAHAR AVE	90744	15	030B213    32	7425038034	[Q]MR2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM			PC Approved	09/14/2016 12:00:00 AM	ADDRESS	33.78138	-118.24622	PC FOR T24 ENERGY ONLY FOR TRUCK LOADING AND UNLOADING AREA. NEW LIGHTING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31125	19041-10000-31990	12716 N JIMENO AVE	91344	12	222B133   633	2602021011	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	34.30162	-118.50266	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 35 MODULES (Q-CELL 285W) , 35 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE7600H-US).  SYSTEM SIZE IS 9.98KWdc and 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31126	18041-20000-40742	20108 W MAYALL ST	91311	12	204B113   506	2741012015	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.25351	-118.5716	PV1.  Install 8.4 kW roof mounted grid tied PV system.  (24) modules and 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31127	16041-20000-14708	13131 N MESA VERDE WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.31142	-118.40683	Plan check for a PV1 roof-mounted PV addition onto an existing system. PV system addition size is 3 kWac and consists of (1) inverter, (12) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31128	14041-10000-07912	1829 N LEMOYNE ST	90026	13	142-5A209  87	5420012003	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.08554	-118.25483	PV1,INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(16) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31129	19041-10000-25580	6010-6020 W AVION DR UA Hangar-and GSE	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	12/01/2021 12:00:00 AM	ADDRESS	33.94244	-118.38762	FULL PLAN CHECK FOR POWER AND ENERGY, [UNITED AIRLINES HANGER] WITH [GROUND SERVICE EQUIPMENT] (2) NEW 4000amp 4160volt SERVICES WITH DISTRIBUTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31130	16041-20000-43178	22950 W VANOWEN ST B	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.19343	-118.62746	Conversion of portion of an (E) retail space into restaurant of a lowrise commercial building.   Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31131	11041-20003-14042	15222 W VENTURA BLVD	91403	5	168B145   995	2276007058	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.15331	-118.46466	(((CHANGES MADE TO APPROVED SET OF PLANS.  CHANGED FIXTURES IN REC, GYM, AND INTERNET ROOMS. ADDED COMPRESSORS. CHANGE FEEDER AT MSA TO ALUMINUM WIRE. CHANGED FEEDERS TO HPA, HP, AND HPR TO ALUMINUM WIRE. REVISED LOAD CALCS)))))NEW 5-STORY MIXED USE RESIDENTIAL AND COMMERCIAL BUILDING.  50 RESIDENTIAL UNITS WITH COMMERCIAL SPACE BELOW.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31132	17041-20001-32569	2408 E RIVERDALE AVE	90031	13	145-5A217 197	5445016015	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.09189	-118.23357	Expedited plan check fee. PV1.  Install 5.7 kW roof mounted grid tied PV system.  (19) modules with (1) 5 kW rated string inverter.  13.5 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31133	19041-20000-42224	12517 N CASCADE CANYON DR	91344	12	219B129   441	2601060003	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.2966	-118.52155	PV1.  Install 16.7 kW roof mounted grid tied PV system.  (50) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31134	19041-10000-34083	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-2D-CPIO	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.76597	-118.28407	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31135	14041-10000-18795	2716 W OLYMPIC BLVD	90006	10	129B197   223	5078010028	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.05243	-118.29218	Plan check for power and energy.  Total area = 7,015 sq. ft.  New connected load = 485.9 ATI for existing commercial mall space + installation of 9 new panels.Building application was submitted 6/4/2014 (before title 24 part 6 effective date).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31136	15041-10000-16492	24500 W PAT PL	91367	3	177B085   536	2032014002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.17822	-118.65852	PV1, INSTALL 14.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(43) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-3.8 AND PVI-3.8 AND PVI 5000-OUTD -US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31137	13041-10000-30858	1205 S SANTEE ST UNIT B	90015	14	124-5A209  94	5145028017	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.03618	-118.25774	Remove HID light fixtures and replace with new fluorescent fixtures in retail space.  Title 24 only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31138	11041-10000-06356	189 S THE GROVE DR #O30	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	T.I.  EXISTING RETAIL SPACE.  TITEL 24 PLAN CHECK ONLY.  USING TAILORED METHOD.  SPACE NUMBER O30	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31139	15041-20001-16263	936 S OLIVE ST UNIT 256	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #2 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31140	13041-10001-27110	5519 N VOLETTA PL	91607	2	174B161   561	2346001006	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.17083	-118.41123	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. CENTRAL INVERTER STANDARD PLAN. SYSTE  SIZE: 9kW.(36) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31141	17041-20000-15994	3221 S LA CIENEGA BLVD	90016	10	120B173    38	4205035007	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	34.02888	-118.37221	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 4,950 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31142	14041-10000-25669	801 S GRAND AVE	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM			PC Info Complete	10/14/2014 12:00:00 AM	ADDRESS	34.04581	-118.25842	Outdoor lighting plan check for a high rise building; remodel area includes first floor lobby and new outdoor overhang .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31143	14041-10000-16583	11620 W WILSHIRE BLVD 800	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	06/09/2022 12:00:00 AM	ADDRESS	34.05021	-118.45963	Plan check for energy only. Suite 800. High rise with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31144	16041-20001-29237	21030 W BLYTHE ST	91304	3	189B105   233	2109013005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.21507	-118.59186	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (35) modules, (35) micro-inverters, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31145	14041-10002-08182	7007 W IMPERIAL HWY	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM			PC Approved	08/07/2014 12:00:00 AM	ADDRESS	33.93185	-118.41447	(8/7/14) Changes to approved set of plans: addition of 1 relay device. delta 2 changes only.CHANGES TO APPROVED: relocation of devices. no addition of devices. plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31146	14041-10001-30532	639 N BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	PIN	34.05985996	-118.23998637	ORIGINAL APPLICATION WAS FOR TITLE 24 PLAN CHK; SUPPLEMENT APPLICATION IS FOR POWER PLAN CK((((((((TENANT IMPROVEMENT IN EXPRESSBANK IN CHINATOWNPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31147	12041-10001-25454	888 S OLIVE ST	90014	14	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			11/06/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Expired	04/26/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	Revisions to to permitted set of plans: added feeder for retail space; changed main for residential switch board to 4500A;added 18 presedential apt units; added 9 feeders to replace 3000A busduct to supply residential distribution boards; show separtion of sections for the generator distribution board and show fire pump emergency sections separate from the other sectionsNOTE TO PLAN CHECK: PROJECT MANAGER, MATTHEW GLEESON, TOOK PLANS BACK TO UPDATE ADDITIONAL CHANGES ON 11/13/2013; IF THOSE ADDITIONAL CHANGES EXCEED THE ORIGINAL SUBMITAL FEES THE PLANS WILL BE SUBJECTED TO ADDITIONAL FEES TO REFLECT THE OVERALL CHANGES.  ((((((((((NEW 33 STORIES HIGH-RISE MIXED USE BUILDING ( COMMERCIAL AND 283 UNITS ) OVER PRIVATE PARKING GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31148	16041-10000-43757	1604 E 27TH ST	90011	9	117A213   389	5117004035	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.01262	-118.2453	Plan check for PV roof mounted system. System size: 3.0kW with 7 modules and 1 inverter(3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31149	17041-10004-24720	1350 N IVAR AVE	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM				DELTA C REVISIONS TO PERMITTED SET OF PLANS; ATTACHED ARE  LISTS OF CHANGES MADE DURING CONSTRUCTION;  CHANGES ARE  CLOUDED ON THE PLANS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31150	13041-10001-20412	12746 W JEFFERSON BLVD #1160	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	REVISIONS TO PERMITTED SET OF PLANS: RTU'S ARE SUPPLIED FROM NEW 120/208V PANEL; 3 EA NEW CKTS; AND XFMR 150KVA REPLACES 75KVA XFMR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31151	12041-20000-19064	6707 W SUNSET BLVD	90028	13	147A185    51	5547020003	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.09815	-118.33661	Plan check for energy and emergency lighting. Commercial. Javista Organic Coffee Bar. 555sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31152	13041-10000-33108	11021 N GLORIA AVE	91344	12	210B141   712	2667009017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.27057	-118.47931	PV1, Install 6 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE6000A-US. (24)modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31153	11041-20000-00383	15055 W OXNARD ST	91411	6	177B145   426	2242027024	M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Public Safety Only			01/07/2011 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.17956	-118.46092	Plan check for new installation of fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31154	16041-20001-35699	5166 N AVENIDA HACIENDA	91356	3	171B125   434	2161023004	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.16517	-118.5335	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 24.85 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31155	18041-10000-07442	6400 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	34.18688	-118.64253	PC for T24 only for replacement of indoor-outdoor existing fixtures with LED fixtures for Chase bank. Total area Indoor  is 11600sqft.Plan checker to verify address	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31156	18041-10000-37954	526 S OCCIDENTAL BLVD	90057	1	135A201   113	5155011016	C2-2	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.06411	-118.28406	Tenant improvement to existing (736 sq ft) restaurant space. T-24 Energy.Plan Check Only. Electrical Permit was issued: 18041-10000-30555Bldg Permit: 18016-10000-17068	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31157	15041-10000-05798	12121 W BLUFF CREEK DR	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	33.97874	-118.40463	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2929.  SCOPE OF WORK ELEVATOR LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31158	12041-10000-05375	16416 W PARTHENIA ST	91343	12	195B137   849	2689028008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	07/02/2012 12:00:00 AM	ADDRESS	34.22828	-118.49017	Plan check new roof mounted 5.64KW photovoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31159	18041-10000-09063	3865 S BUDLONG AVE	90037	8	117B197   758	5037010003	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Expired	10/17/2023 12:00:00 AM	ADDRESS	34.01586	-118.29599	NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 3.0KWdc / 2.8KWac. PV SYSTEM IS  CONNECTING TO THE POINT OF INTERCONNECTION OF A SINGLE FAMILY HOME.(10)MODULES-SOLARWORLD SW 300(10)MICROINVERTERS-ENPHASE S280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31160	14041-10000-15570	423 E WASHINGTON BLVD	90015	14	123A209   365	5127021019	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.02931	-118.26043	Title 24 plan check only.  Total area = 11700 sq. ft.Remove HID light fixture and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31161	16041-20001-17674	380 N CAROLWOOD DR	90077	5	141B157    10	4358006033	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	06/03/2016 12:00:00 AM	ADDRESS	34.08562	-118.4289	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31162	15041-10001-40513	11440 W VENTURA BLVD SUITE 101	91604	2	162B169   680	2378022023	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.13941	-118.38026	Supplemental change to approved set, revised multi level lighting control on 4 rooms. Permit under 15041-10000-40513****MASSAGE PARLOR TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31163	19041-20000-23545	11847 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.28595	-118.38982	Plan check for Title 24 only outdoor site lighting in 39 Single Family. Total outdoor area: 58,967 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31164	17041-30000-07642	16417 W BAHAMA ST	91343	12	195B137   245	2688008009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.23303	-118.49023	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31165	17041-10001-32559	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.06371	-118.2982	Change to approved set by adding new panels and ckts on the floor plan. All changes under delta-1 only.(((Plan check for power only. Core and shell/Change of use from residential studio to office. Building is historical. New 1,000A 277/480V 3ph 4w service.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31166	17041-10000-31015	13919 W FOOTHILL BLVD	91342	7	225B153   325	2509002041	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.31242	-118.43638	CAR WASH. NEW BUILDING. PC FOR POWER AND ENERGY. B# 17010-20000-02103	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31167	17041-10000-38823	16301 W RAYMER ST	91406	6	189B137     8	2205029042	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.21806	-118.48757	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 11000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31168	11041-20000-20815	2700 W COLORADO BLVD	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.14248	-118.22438	T24 ENERGY FOR TENANT IMPROVEMENT ON EXISTING RETAIL (TARGET)  FITTING ROOM AND SALES AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31169	12041-10000-30108	23132 W LEONORA DR	91367	3	171B097   704	2042011059	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.16393	-118.63023	New roof mounted PV system with 6.38 KWdc for SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31170	18041-10003-09270	3836 N HAYVENHURST DR	91436	5	162B141   231	2286021041	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM			Reviewed by Supervisor	07/02/2019 12:00:00 AM	ADDRESS	34.14043	-118.48528	Plan check to restamp an approved lost set. PLAN CHECK ONLY. Permit fees paid under 18041-10000-09270 Original Scope of work: ((PC for 40kW(ac) PV ground mounted system for SFD. Installing 140 modules [44.8kW(DC)], 140 optimizers, 225 load center and four 10kW central inverters connecting system to line side of main panel.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31171	19041-20000-28718	8777 N SAN FERNANDO ROAD	91352	6	195B169   446	2631034025	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.22869	-118.3828	T24 PLAN CHECK FOR LIGHTS AND OUTLETS FOR EXISTING COMMERCIAL BUILDING. CHANGE OF USE 2ND FLOOR STORAGE TO OFFICE AND STORAGE. TOTAL SQUARE FOOTAGE = 1300 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31172	15041-10000-37160	1015 N MANZANITA ST	90029	13	145-5A201 477	5427002006	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Refund in Progress	06/27/2016 12:00:00 AM	ADDRESS	34.09112	-118.28252	VOID......PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) KYOCERA MODULES 265WATTS(1) PVI 3.0KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31173	14041-20000-05279	22210 W TIARA ST	91367	3	177B101   261	2146021003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.17795	-118.61061	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31174	19041-20001-17272	11963 N RICASOLI WAY	91326	12	216B109   336	2701085017	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM	ADDRESS	34.29049	-118.58494	08-09-2019 Changes to an approved set of plan, Changes include addition of disconnect on the exterior structure for Tesla Battery. Changes has been clouded.Plan check only. Fees $0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31175	12041-10000-01882	8505 W FOOTHILL BLVD	91040	7	207B189  1077	2555033031	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM			Corrections Issued	01/25/2012 12:00:00 AM	ADDRESS	34.25989	-118.31823	PLAN CHECK T24 ENERGY FOR NEW CARWASH BUILDING TO EXISTING GAS STATION. WORK NOT IN CLASSIFIED AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31176	12041-10000-07261	5955 N LANKERSHIM BLVD	91601	4	177B169   914	2338009004	RD2-1, [T][Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	08/28/2012 12:00:00 AM	ADDRESS	34.17886	-118.3833	Plan check for new fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31177	15041-20000-09944	19349 W KITTRIDGE ST	91335	3	180B117   444	2131006029	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.19084	-118.55529	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system with 16 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31178	19041-10000-49817	4836 N STROHM AVE	91601	4	168B177   370	2420005004	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.15874	-118.35917	New PV1 rooftop installation with a system size of 5.8 KW DC/ 5.0KW AC with 20 modules (REC290TP2), 20 power optimizers (P320), a central inverter (SE5000H-US) connected to new service panel of 125A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31179	16041-20001-33294	23936 W SCHOENBORN ST	91304	12	192B089   143	2017037011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.22084	-118.64838	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a roof-mounted pv system for a SFD.  Interconnect with a 400A MSP. 3kW ungrounded system. (12) 265W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31180	12041-20000-17345	2010 S CENTURY PARK EAST 3rd floor	90067	5	132B161    28	4319001803	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.05986	-118.413	T-24 energy plan check only for a partial 3rd floor plan remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31181	16041-10000-00248	1829 W 79TH ST	90047	8	099B193   777	6017032021	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Expired	02/02/2018 12:00:00 AM	ADDRESS	33.9674	-118.31006	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.72KWdc/4.73KWac(22)MODULES-HANWHA Q CELLS Q.PRO BFR-G4 260(22)MICROINVERTERS-ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31182	13041-20002-03721	1901 S BUNDY DR BLDG 1	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.03497	-118.45709	changes to approved set of plans. changes to site lighting. plan check only t24 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31183	14041-10000-17288	21255 W BURBANK BLVD	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR THE CORRIDORS ON THE 4TH FLOOR. 2697 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31184	14041-20000-22482	18325 W KINGSBURY ST	91326	12	207B125   378	2731003011	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.26283	-118.53266	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(18) SUNPOWER SPR-327NE MODULE(1) POWER ONE PVI-6000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31185	19041-10000-14096	1180 S LA BREA AVE	90019	10	129B181    68	5084021018	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Apartment			04/17/2019 12:00:00 AM	04/23/2020 12:00:00 AM		Permit Finaled	02/22/2024 12:00:00 AM	ADDRESS	34.05384	-118.34332	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 7 STORY MIXED USED 67 UNITS APARTMENT WITH RESTAURANT. SCOPE OF WORK INCLUDES NEW 2500AMPS SERVICE,208/120 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 50027 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31186	11041-10000-12764	301 WORLD WAY parking	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/03/2011 12:00:00 AM	ADDRESS	33.94423	-118.40709	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31187	12041-10000-00253	13300 S ESTRELLA AVE	90248	15	078B201    65	6132004029	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Expired	02/11/2014 12:00:00 AM	ADDRESS	33.91139	-118.28597	37 New fire alarm devices added to an existing fire alarm system for an existing air plane part manufacturing building.  Fire alarm control panel is existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31188	11041-20001-17230	3041 W 7TH ST	90005	10	132B197   169	5077011018	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Apartment			11/02/2012 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	34.05992	-118.29006	Changes to approved set of plans. Removal of fire pump from emergency source. Changes to single line diagram, minor changes to branch circuits. Packet is included showing all changes. NO CHANGES TO LIGHTING.  Site is in a Methane Buffer Zone Level I, with a pressure less than 1 per report. New 133 unit residential building.  Building is 4 story plus subterenean garage.  Plan check is for energy and power.  Fire alarm will be submitted separately.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31189	14041-10000-22747	812 S NORTON AVE	90005	4	132B189   642	5092015022	R2-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM			Corrections Issued	08/21/2014 12:00:00 AM	ADDRESS	34.05783	-118.31852	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.5 KW AC. grounded system.(24) RENESOLA  300W MODULES(1) FRONIUS IG PLUS 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31190	17041-10000-15683	5150 W PICO BLVD	90019	10	129B181   982	5070014006	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Issued	05/11/2017 12:00:00 AM	ADDRESS	34.04792	-118.3507	T24 ONLY. REPLACE EXISTING HID LIGHT FIXTLURES WITH NEW LED LIGHT FIXTURES. TOTAL ARE  A  4925 SQ FT. OUTDOOR  LLIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31191	18041-10000-18753	14915 S FIGUEROA ST	90248	15	072B201    37	6120029002	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM			Corrections Issued	05/23/2018 12:00:00 AM	ADDRESS	33.89667	-118.28339	PC FOR REMODEL AND ADDITION OF (E) WAREHOUSEFOR TITLE 24 ENERGY ONLY.  TOTAL AFFECTED AREA 2476 SQ.FT SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT AND LIGHTS. B#18014-10000-02305	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31192	12041-20000-29265	1850 E 15TH ST	90021	14	120A215   164	5167019021	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.0229	-118.2374	Plan check for power and energy. New warehouse addition to an existing 800A service. Single story 7461 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31193	14041-10000-30773	21431 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM			PC Approved	12/04/2014 12:00:00 AM	ADDRESS	34.25739	-118.59841	Title 24 only.  Installation of two new lights in a ralphs store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31194	13041-10001-29486	5334 N OVERING DR	91367	3	171B089   136	2047018016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.16722	-118.64765	Expedited RSES plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31195	11041-10000-10415			6	183B149   647	2217009011	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM			PC Approved	05/20/2011 12:00:00 AM	PIN	34.195128	-118.4475259	T-24 and emergency lighting plan check for the first floor of a building where there was a change of occupancy from office to private school.    CHANGE OF USE FROM OFFICE (B-OCC)  TO PRIVATE SCHOOL (E-OCC, CHARTER SCHOOL FOR GRADE 9~12) AND INTERIOR NON-STRUCTURAL TENANT IMPROVEMENT ON 1ST , 3RD  AND  4TH  FLOOR OF EXISTING   8 STORY,TYPE I-B, BUILDING. NFPA-13 SPRINKLERED BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31196	16041-20000-14138	3515 W HYDE PARK BLVD	90043	8	105B185  1231	4006007028	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			04/29/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	33.98072	-118.33417	Plan check for power and energy. NEW 5-STORY 51 UNIT APARTMENT BUILDING. 1200A service.Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31197	17041-20000-45167	17627 W VENTURA BLVD	91316	5	171B129   337	2257008040	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Issued	01/03/2018 12:00:00 AM	ADDRESS	34.16227	-118.51713	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM (E) BARBER SHOP (14VN129031) TO NAIL SALON. 1377 SQFT.BUILDING P# 17016-20000-30691	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31198	18041-20000-00609	11755 W WILSHIRE BLVD Ste 1200	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	02/24/2018 12:00:00 AM	ADDRESS	34.04856	-118.46231	Tenant improvement to (E) high-rise commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31199	12041-10000-23469	11831 W VOSE ST	91605	2	183B169   185	2321004004	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			10/02/2012 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.19855	-118.39129	NEW WAREHOUSE / OFFICE BLDG -	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31200	19041-20000-19121	3700-3710 W LOS FELIZ BLVD ev2	90027	4	153A205     2	5434015001	RD1.5-1XL	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	Apartment			05/21/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Issued	12/04/2019 12:00:00 AM	ADDRESS	34.11539	-118.2734	ev2install 16 EV charging stations to an existing apartment building.  plan check for power.energy management system installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31201	15041-20000-07170	18000 W DEVONSHIRE ST	91330	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.25313	-118.52557	Plan check for T-24 only for office space. Total area: 937 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31202	15041-20000-25325	6344 N TOPANGA CANYON BLVD A-1080	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	Plan check for power and Title-24 (energy).  Total area = 4,197 sq. ft.  T.I. to commercial first time tenant.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31203	13041-10000-33548	15825 W STAGG ST	91406	6	189B141   164	2206002032	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Closed	04/30/2014 12:00:00 AM	ADDRESS	34.21218	-118.47807	Remove HID light fixtures and replace with new fluorescent fixtures in warehouse space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31204	16041-10000-36309	10250 W SANTA MONICA BLVD STE. 1660	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""L'Occitane"" Ste. 1660.  Install new electrical equipments: 30kVA transformer and 2  panels,  total effected area: 550 sq.ft T-24 using Tailored method"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31205	15041-20002-39931	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Closed	03/08/2018 12:00:00 AM	ADDRESS	34.23911	-118.3725	TI TO RESTROOMS AND ADDITION OF RECEPTACLES IN NORTH/SOUTH SIDE RESTROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31206	16041-20000-04859	21650 W OXNARD ST Suite 1750	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 4,683 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31207	14041-20000-14259	10455 W MAGNOLIA BLVD	91601	4	171B177   637	2417017001	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	Apartment			05/29/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/26/2016 12:00:00 AM	ADDRESS	34.16508	-118.35903	New three story and 26 unit apartment building with 1 level sub. parking.  Install new 1200A service, panels, branch circuits, and ligting.  Plan check for power and energy.Note: Variance to separate fire alarm system submit on 5/29/14.  Fee shall be recalculated due to presigned check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31208	10041-10000-15497	12181 W BLUFF CREEK DR 3RD Floor	90094	11	102B161  1150	4211010061	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	09/22/2010 12:00:00 AM	ADDRESS	33.97788	-118.40638	TI IN AN EXISTING OFFICE AREA ON THE 3RD FLOOR.           PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.    PERMIT IS FOR NEW CIRCUITS & LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31209	12041-10000-26924	3800 W MT LEE DR	90068	4	159B189    10	5581010900	OS-1XL	Central	Hollywood	Hollywood United	YES	9800.09	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Info Complete	04/22/2014 12:00:00 AM	ADDRESS	34.13546	-118.3184	"New un-maned radio communication building for the police, fire and ""911"" center.  Install two 600A services, two emergency generators, panels, and lighting.  Plan check for power and energy.  Note: The installation of the rectifier systems is not in the scope of work in this application as indicated on the plans."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31210	18041-10000-40671	355 S GRAND AVE 9TH FL-RM#9122	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM			PC Info Complete	10/24/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR T24 ONLY, TI  TO AN EXISTING TENANT CONFERENCE ROOM #9122. NO CHANGE OF USE. TOTAL AREA 312 SQ.FT(B# 18016-10000-32966)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31211	13041-20001-22955	3221 W TEMPLE ST	90026	13	139-5A201 237	5156007015	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village		1958.02	Electrical	Electrical	Apartment			11/10/2015 12:00:00 AM			PC Approved	11/10/2015 12:00:00 AM	ADDRESS	34.07565	-118.28154	CHANGE OUT CONDUCTORS TO ALUMINUM. ADDED SERIES RATING NOTES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31212	13041-20000-23949	8900 N DE SOTO AVE	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.23162	-118.58832	T24 FOR OUTDOOR LIGHITING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31213	11041-20000-08431	7648 N CLYBOURN AVE	91352	2	186B177   576	2466029049	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.20933	-118.36317	PLAN CHECK POWER AND ENERGY FOR EXISTING WAREHOUSE.  NEW EQUIPMENT, CKTS, AND PANELS ADDED TO EXISTING 1600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31214	16041-10000-45431	5725 E YORK BLVD	90042	14	154-5A229  74	5484010016	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.11887	-118.19277	FULL PC FOR A NEW MCDONALDS RESTUARANT. SCOPE INCLUDES A NEW 1000A 1230/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 27988 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31215	18041-20000-45839	12928 W SHERMAN WAY	91605	2	183B161    47	2327018072	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM			PC Approved	12/03/2018 12:00:00 AM	ADDRESS	34.20093	-118.41462	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31216	15041-10002-18741	12415 N SAN FERNANDO ROAD	91342	7	219B149   666	2611007035	(T)(Q)C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Apartment			08/03/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.29585	-118.45528	"08/03/16Changes to an approved set of plans. All changes are clouded under delta 5. Changes include removing the 2"" concrete encasement and using a 24"" burial depth.Note: permit is pulled under PCIS#15041-10000-18741 (((((PC FOR POWER AND ENERGY.  FOUR STORY ,101-UNIT APARTMENT 3000A SERVICE. TOTAL AREA 66,779 SQ FT(INDOOR) PLUS 11672 SQ(OUTDOOR)."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31217	14041-10000-04576	1015 S CROCKER ST #R-10	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	"PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 320 SQFT. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31218	19041-10000-35906	12833 N EL DORADO AVE	91342	7	222B145   297	2604016019	R1-1-K	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.3032	-118.46807	PV1. NEW ROOFTOP SOLARSYSTEM CONSIST OF 15 MODULES (Q-PEAK 305), 15 OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTER (SE 5000H-US) CONNECTED TO A 200A UPGRADED SERVICE. SYSTEM SIZE IS 4.8KWdc AND 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31219	13041-10000-23730	1901 W MONTIFLORA AVE	90041	14	162A223   327	5686011019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.13654	-118.20907	ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE 3.185 KW DC FOR A 2-STORY HOME.TRANSFORMERLESS INVERTERS WITH POWER OPTIMIZERS, UNGROUNDED SYSTEM.(13) MODULES: TRINA SOLAR #TSM-245PC05/PA05.18(1) INVERTER: SOLAREDGE #SE3000A-US(13) OPTIMIZERS: OP250-LV	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31220	13041-20000-35516	7349 N PONCE AVE	91307	12	186B097   745	2022006004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Expired	01/14/2016 12:00:00 AM	ADDRESS	34.20423	-118.62118	PV1 TRANSFORMERLESS SYSTEM. USING POWER OPTIMIZER. TOTAL SYSTEM SIZE 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31221	13041-20000-27923	3725 N ROSEMEAD AVE	90032	14	144A233   286	5306015055	RD3-1	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Expired	11/24/2015 12:00:00 AM	ADDRESS	34.08796	-118.17656	PV2 MULTI FAMILY DWELLING. PC FOR 6KW AC USING 22 MODULES WITH CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. PERMIT ALREADY ISSUED UNDER APPLICATION #13041-20000-17660	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31222	14041-20001-32178	17520 W MAYALL ST	91325	12	204B129   413	2734017003	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM			PC Approved	12/15/2014 12:00:00 AM	ADDRESS	34.25382	-118.51651	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(30) CANADIAN SOLAR CS6P-250P MODULES(1) SE6000 SOLAR EDGE TRANSFORMERLESS INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31223	12041-20000-08326	5555 W MELROSE AVE Edith Head-Building	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Finaled	05/03/2014 12:00:00 AM	ADDRESS	34.08363	-118.32191	Paramount pictures, Edith Head Building.  Up grade entire electrical system, and reconnect existing branch circuits and non dwelling power equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31224	16041-10002-27954	19681 S PACIFIC GATEWAY DR	90502	15	057B197    35	7351034056	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.85319	-118.29547	CHANGE TO APPROVED SET OF PLANS - CHANGES INCLUDE UPGRADE OF 400A PANEL TO 600A, AND UPGRADE INVERTERS AND STORAGE SYSTEM FROM (2)100KW TO (2)132KW OUTPUT POWER FOR STORAGE SYSTEM (3.1). FOR BATTERY SYSTEM 1 (POWER STORE 1.4), THESYSTEM SIZE STAYS THE SAME BUT RELOCATION OF EQUIPMENT AND ADDITION OF MONITORING SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31225	19041-10000-11628	5115 W WILSHIRE BLVD STE E	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.06233	-118.34134	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES A SALON. TOTAL AFFECTED AREA IS 924 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31226	13041-10000-01989	1431 E 110TH ST	90059	15	088-5A211 283	6070004900	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	33.93592	-118.24921	Plan check power and energy for new LA Rec & Park building. Swimming pool, Filtration lighting, and filtration equipment in building on separate permit. EV charging station on separate permit. Main building supplying separate changing room building under #13041-10000-09774	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31227	14041-20000-17279	2022 W SUNSET BLVD	90026	13	139-5A207  91	5404003035	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Apartment			06/26/2014 12:00:00 AM			PC Info Complete	03/03/2015 12:00:00 AM	ADDRESS	34.07751	-118.2627	4 STORY 36 UNIT APT WITH SUBTERRAINIAN PKG. PC FOR POWER AND ENERGY. NON METHANE.FIRE ALARM VARIANCE HAS BEEN FILEDDUE TO BUILDING SUBMITTAL, PLAN CHECK FOR ENERGY ACCORDING TO 2008 EFFICIENCY STANDARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31228	14041-20000-13081	947 N RIVAS CANYON ROAD	90272	11	129B129   688	4409005017	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.04757	-118.51497	(($0 permit fee due to senate bill 1222 from 2012)))PV1 roof-mounted system with 13.3kw, (48) Sun Power SPR-327NE-WHT-D modules, and (2) Sun Power SPR-6000m string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31229	09041-10001-17580	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM			PC Approved	01/06/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	REVISIONS TO APPROVED SET OF PLANS - SHOW ON THE PLANS THE GROUNDING ELECTRODE FOR THE UPS SYSTEM AND THE BONDING OF THE BATTERY CABINETS ALSO CHANGE A RECEPTACLE TO ONE OF 30A,115V	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31230	11041-10000-14809	6222 W MANCHESTER AVE	90045	11	096B165   561	4123003019	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00, 2780.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	11/10/2011 12:00:00 AM		Permit Finaled	03/05/2012 12:00:00 AM	ADDRESS	33.95969	-118.39442	TENANT IMPROVEMENT OF MEDICAL FACILITY FOR AN INTERNAL MEDICAL PRACTICE.  PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31231	16041-10000-33586	19851 W NORDHOFF PL #105	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.23624	-118.56649	Title 24 to existing 2 story building. Change of use from wherehouse into offices. Adding new lighting and power. Total sqft = 2683.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31232	17041-40000-25393	3831 N DIAMANTE PL	91436	5	162B137   386	2293002014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.13961	-118.49548	roof mounted PV. 10kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31233	19041-10000-24674	5500 E VALLEY BLVD	90032	14	138A237    76	5221012219	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.07377	-118.16304	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31234	19041-10001-03191	13438 W OXNARD ST	91401	2	177B157   881	2343021014	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM			PC Approved	08/06/2019 12:00:00 AM	ADDRESS	34.17926	-118.42606	Changes to approved set, scope of work is reloaction of solar equipment from the inside to the exterior of the house. All changes are under delta one, plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31235	12041-10000-15645	5755 N ALLOTT AVE	91401	2	174B157   190	2343010012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.17554	-118.42812	Plan check for PV system. Single Family Dwelling. Roof mounted. Transformer-less inverter. 5.886 kW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31236	12041-10000-15443	6600 N TOPANGA CANYON BLVD # 77	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	Install new circuits for power and lighting IN EXISTING RETAIL STORE, space # 77.  Plan checked for T-24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31237	18041-10000-48521	1724 N HIGHLAND AVE	90028	13	148-5A185  63	5547011035	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	34.10238	-118.3385	REPLACE 12 EXISTING LIGHT FIXTURES W/12 NEW, ADD 4 RECEPTICLES TO AN EXISTING CURCUIT AND ADD 2 LIGHTS TO AN EXISTING LIGHTING CIRCUIT.  T-24 ENRGY ONLY. (TOTAL OF 495 SQR FT.) PLAN CHECK ONLY. ELECTRICAL PERMIT WAS ISSUED UNDER: 18041-40000-35254	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31238	15041-20000-01101	14276 W AZTEC ST	91342	7	219B153   319	2507026005	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.29649	-118.44427	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.8KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31239	18041-20000-27077	15030 W VENTURA BLVD #22	91403	4	168B145  1143	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.15272	-118.46063	Plan check for Title 24 only in existing space change of use from retail to restaurant T.I. Total area: 840 sq ft. B#18016-10000-18448	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31240	19041-10000-22832	2905 W EXPOSITION PL unit 4	90018	10	117B185    13	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.02038	-118.3277	Plan check for a 3KW AC/ 2.6KW DC PV2 roof mounted system with (1) inverter and (8) modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31241	15041-20004-02895	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	"Changes to approved set.   Relocation of 75 kVA transformer ""T6"" to open warehouse space.  New transformer secondary length is 40'."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31242	15041-20000-05819	7337 W PACIFIC VIEW DR	90068	4	156B177   611	2428016005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM			Reviewed by Supervisor	03/10/2015 12:00:00 AM	ADDRESS	34.12144	-118.35321	Plan check for PV1 roof mounted 9.8kW system using micro-interters with 46 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31243	10041-10000-01494	6645 N WOODMAN AVE	91405	2	180B157   335	2238011080	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10, 1281.00	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	PIN	34.19151504	-118.43164512	New 25.83 KW PV system for a commercial building. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31244	14041-10000-07882	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.22149	-118.43179	PLAN CHECK FOR POWER IN KAISER PERMANENTE BLDG. UPGRADING TO NEW SYSTEM, NEW PANELS, SWITH GEARS AND TRANSFORMERS. NUMBER OF DEVICES PER APPLICANT AND MEHDI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31245	19041-30000-46409	3640 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Info Complete	11/12/2019 12:00:00 AM	ADDRESS	34.01993	-118.37802	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 3666 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31246	16041-10002-27194	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	33.97954	-118.41361	08/11/17Changes to an approved set of plans. All changes are clouded under delta RFI-063 . Changes include adding a new X -Ray machine on the single line diagram, and revising floor plan.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31247	19041-20000-23201	20444 W VIA CELLINI	91326	12	219B109   258	2701055008	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.29443	-118.58072	addition of (2) tesla ESS rated 5KW each to an exisitng pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31248	10041-20000-06404	7651 N DENSMORE AVE	91406	6	186B141    24	2206010008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	34.21003	-118.47725	OFFICE TIEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31249	15041-10000-06395	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	T24 FOR EXISTING RESTAURANT SPACE 2528 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31250	19041-10000-32687	414 N ORLANDO AVE	90048	5	141B173  1356	5514003010	R1V3-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.07889	-118.37302	PC FOR PV-1, SYSTEM SIZE IS 5.440KWDC, 16 MODULES WITH MICROINVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31251	15041-10000-01826	3413 N ADINA DR	90068	4	159B177   750	2427001015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.12827	-118.35313	Plan check for a PV1 roof-mounted PV system. System consists of (35) modules and (2) inverters. System size is 7.2 kWac. Using standard plan.Reason for in-person PV plan check: address was not found in PCIS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31252	19041-20000-07624	4525 W WILSHIRE BLVD Ste 220	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.06211	-118.32869	TI to (E) commercial office space.  Plan check for energy - 6109 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31253	18041-10000-43714	1317-1319 S WESTERN AVE	90006	10	129B193  1402	5073010002	C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	34.04666	-118.30926	"TITLE 24 ONLY FOR ONE ONSITE ILLUMINATED WALL SIGN WITH LOGO (2' X 6.5') ""MICHELIN.""; 13'-6"" ABOVE GRADE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31254	14041-20000-06950	10180 N STONEHURST AVE	91040	7	204B173   165	2528018008	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	PIN	34.25541267	-118.37332746	PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31255	13041-20000-29091	333 S GRAND AVE 12TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR T24 ENERGY ONLY. TOTAL AREA 1670 SQ FT. BATHROOM AND OFFICES. WORK ON 12TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31256	10041-20003-25118	1200 S SANTA FE AVE	90021	14	123A217   315	5166007011	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Info Complete	07/29/2013 12:00:00 AM	ADDRESS	34.02944	-118.22979	"changes to approved set of plans. plan check only for ""DELTA 1"". split buss. reduce loads. existing elevator noted to be 7.6 hp. corrected notation. original application #10041-10001-25118  ""COMPLY WITH DEPARTMENT ORDER effective date 11/18/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31257	16041-10000-28683	8532 W CASHIO ST	90035	5	129B173   569	4303032005	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.05076	-118.37735	Plan check for New Fire alarem system on 4 story building. Total fire alarm devices: 56 and New FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31258	19041-20001-34472	10985 W BLUFFSIDE DR PV1	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.14183	-118.36949	PV2 BUILDING #5 (N) 17.5 KW AC/19.44 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (54) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31259	10041-10000-22249	666 N KILKEA DR	90048	5	141B173   460	5528010001	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.0834	-118.36681	Change of use from delling unit to jewelry storeplan chk is for title 24 ( indoor and out door )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31260	13041-20000-18598	3319 N WRIGHTWOOD DR PV-1	91604	2	159B173   428	2380014040	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00, 1438.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2013 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	34.13176	-118.37512	PV-1. Microinverter plan. 31 microinverters for 6.665kW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31261	18041-20000-09404	515 W 117TH ST	90044	15	084B201   512	6088013024	R4-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Apartment			03/14/2018 12:00:00 AM			Reviewed by Supervisor	04/25/2018 12:00:00 AM	ADDRESS	33.92749	-118.28317	Plan check for power and energy. Project site is a new 2-story, 12-unit apartment building with a semi-subterranean garage. Work includes a new 800-amp service and a total lighting area of  10,694 sq. ft.Note: Building application has been generated under 18010-10000-01087	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31262	10041-20001-01816	4302 N EAGLE ROCK BLVD	90041	1	156A219   100	5474022009	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1862.01	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM			PC Info Complete	11/01/2010 12:00:00 AM	ADDRESS	34.12254	-118.22318	revision 1 relocate equipment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31263	18041-30000-14411	13394 W DYER ST	91342	7	228B157   635	2511006007	R1-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Re-Activate Permit	11/07/2019 12:00:00 AM	ADDRESS	34.32083	-118.42428	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac. System consists of (1) inverter, (18) modules, (1) load center, and (1) Tesla PowerWall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31264	17041-20000-12424	6600 N TOPANGA CANYON BLVD #2074	91303	3	180B101   822	2139004044	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Issued	07/13/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for energy only. TI to existing space - mall retail (Nespresso), space 2074. New lighting (incl. emergency). 1,798sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31265	14041-20000-07527	1754 E 92ND ST	90002	15	094-5A213 137	6048032020	C2-1VL	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	33.95313	-118.2417	Expand building for a new coin laundry.    New 800A service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31266	18041-20000-49156	21622 W PLUMMER ST	91311	12	198B105    40	2746014042	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM			PC Approved	12/31/2018 12:00:00 AM	ADDRESS	34.24254	-118.60152	Plan check for Title 24 only in corridor  new lighting. Total area: 406 sq ft. B#18016-10000-28261	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31267	10041-10000-01551	3101 N ARTESIAN ST	90031	1	142-5A221 658	5205010900	PF-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	05/10/2012 12:00:00 AM	ADDRESS	34.08214	-118.21723	New 200KW Photovoltaic System for LADWP Artesian Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31268	13041-20000-15949	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	change to lighting and receptacles for an existing on-story car rental office.  Load less than 400 amps per Engineer.  PLAN CHECK ONLY for Energy, NO Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31269	10041-10000-20320	801 S FIGUEROA ST	90017	9	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Public Safety Only			10/14/2010 12:00:00 AM	10/18/2010 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for new installation of fire alarm system in existing highrise building (27 story - 801 Figueroa Tower) .  1 FACP, 1 Ann, and, 1326 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31270	17041-10000-31124	444 S FLOWER ST 14TH FLR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	ADA RESTROOM, PUBLIC CORRIDOR AND ELEVATOR LOBBY FINISH RENOVATION. TI. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31271	19041-10000-36250	750 N GREENTREE ROAD	90272	11	126B129   366	4409022012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Issued	09/11/2019 12:00:00 AM	ADDRESS	34.04261	-118.51585	Plan check for a PV1 7.6KW AC / 9.36KW DC roof mounted system. Scope icludes (1) inverter, (26) modules and optimizers interconnecting through the service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31272	13041-10000-26973	3425 E ALICE ST	90065	1	147A219   247	5454027004	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.09646	-118.22612	PV1. ROOF MOUNTED 3KW PHOTOVOLTAIC SYSTEM. TRANSFORMERLESS INVERTER WITH POWER-ONE # AURORA PV1-3.0-OUTD-S-US AND TRINA SOLAR # TSM-250PA05.18 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31273	13041-10000-13638	4729 N EAGLE ROCK BLVD	90041	14	159A221    95	5685027016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.13117	-118.21666	TI TO EXISTING BLDG. RETAIL TO RESTAURANT. max city bbq	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31274	11041-10001-15489	4225 S CENTRAL AVE	90011	9	114A209   153	5115019***	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Apartment			12/19/2012 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	34.00695	-118.25669	Delta 5 changes. EPC is for T24. Relocate luminaires & emergency lighting.PER INSPECTOR (VIOLATION 12BQF01204: ADD LTG AND REVISED T24/FIXTURE SCHEDULE. LOBBY/main entrance FOR DUNBAR HOTEL. INDOOR AND OUTDOOR.======>>>> REVISE FEES TO INCLUDE OUTDOOR LIGHTING FEES.T.I.  Historical Building.   On the first floor a new community room and four future tenant spaces..  On floors 3-5, rooms are to be converted to new apartments for seniors.Fire alarm plans  submitted on 11041-10000-15497	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31275	14041-20000-05733	11850 W SHELDON ST	91352	6	198B169    65	2538002040	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	34.24066	-118.39159	Resubmit for energy plan check.  The orginal approval application is expired (11041-20000-00305).  Install general/emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31276	19041-10000-04014	11923 ANCONA WAY	91326	12	216B109   342	2701086006	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	PIN	34.28923125	-118.58593472	Plan check for PV1 7.6KW AC / 8.58 KW DC roofmounted system with (1) iverter,  (26) modules and optimizer interconnecting through the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31277	18041-10000-09969	8635 N 3RD ST 790 WEST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Issued	03/22/2018 12:00:00 AM	PIN	34.07407929	-118.38065982	PC FOR TITLE 24 ENERGY ONLY FOR LOBBY AND CORRIDOR TI IN A HIGH RISE. SCOPE INCLUDES NEW LIGHTS IN LOBBY AND CORRIDOR. B#18016-10000-07415REPLACE PORTION OF T-BAR CEILING IN SUITE 790 WEST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31278	17041-10000-27363	1314 S OXFORD AVE	90006	10	129B193  1377	5074002010	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.04665	-118.30679	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 3.2KVA CONSIST OF 10 AC MODULES(SPR-X21-345-C-AC) WITH 320W OUTPUT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31279	18041-10000-33473	2029 S CENTURY PARK EAST # N420	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN AN EXISTING OFFICE AREA IN SUITE # N420. T-24 ENERGY ONLY.  604 SQ FT.BLDG PERMIT 18016-10000-21254	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31280	18041-20000-39530	1923 N GRAMERCY PL	90068	4	150A193   111	5587019007	R1-1D-HPOZ	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.10606	-118.31272	Plan check for PV roof mounted system with energy storage system, PV Syste size: 9.425 KW with 29 PV Modules and 1 inverter(7.6kW) and 1 Tesla Battery 2.0 13.5kWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31281	10041-10000-15158	1610 S BARRACUDA ST BERTH 301	90731		015B205    30	7440032905	M3, [Q]M3-1						Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM			PC Approved	09/10/2010 12:00:00 AM	ADDRESS	33.73169	-118.26381	INSTALLATION OF A 4160V SWITCHGEAR ;PERMIT OBTAINED ON 10041-10000-18057	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31282	19041-10000-32984	1804 N HYPERION AVE	90039	4	147A203   409	5431001014	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.09608	-118.2762	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31283	15041-10000-26324	13652 W CANTARA ST 1st & 2nd-Flr	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.21973	-118.43084	PC FOR POWER FOR DERMATOLOGIST FACILITY. THE SCOPE OF WORK IS BASED ON THE MODIFICATION OF A FEW RECEPTACLES AND LIGHTING FIXTURES. PLANS DO NOT REQUIRE COMPLIANCE SHEETS FOR T-24 SINCE IS LESS THAN 10% ALTERATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31284	18041-10000-46400	9501 N VAN NUYS BLVD	91402	6	198B149    42	2650025037	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.24294	-118.45044	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31285	16041-20000-35936	5200 N LANKERSHIM BLVD 2ND FLOOR	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 2ND FLOOR.  417 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31286	13041-10000-26059	2238 W LOMA VISTA PL	90039	13	147A209   462	5422010006	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Refund in Progress	12/11/2013 12:00:00 AM	ADDRESS	34.0951	-118.25603	PV1. Install 1.5 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: Power-One Aurora PVI-3.0-OUTD-S-US.  6 modules: Trina Solar TSM-250PA05.18	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31287	15041-20000-10550	6344 N TOPANGA CANYON BLVD A-1030	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Closed	04/06/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	MALL RESTAURANT TI - SPACE A-1030 PC FOR POWER AND ENERGY. TAKE OUT RESTAURANT. PART OF WESTFIELD VILLAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31288	16041-20001-36998	2616 N HYPERION AVE	90027	4	150A205   138	5432001012	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Approved	04/11/2017 12:00:00 AM	ADDRESS	34.10594	-118.27246	[[4/11/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES. CHANGING TO OVERHEAD SERVICE ROUTED ON ROOF IN 2 INCH CONCRETE.]]]PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. MAD HATTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31289	17041-10000-08024	7920 S YORKTOWN AVE	90045	11	099B169   949	4107011021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	33.96569	-118.38936	PC for roof mounted PV system with a Tesla storage battery. Solar system size is 5kW with 16 LG PV module.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31290	13041-10000-26400	8500 W BEVERLY BLVD STE 703	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI for (E) 777 SF retail space.  Title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31291	15041-20000-32297	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for power and energy for T.I. clen room renovation Phase 1 of 3. Total area for phase 1 of 3: 3,708 sqft. Newly connected load: 404A. Note: refer to Building permit # 15016-20000-20381	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31292	15041-20001-28266	22701 W DOLOROSA ST	91367	3	174B097   773	2040019010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2015 12:00:00 AM			PC Approved	09/06/2015 12:00:00 AM	ADDRESS	34.17024	-118.62132	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (35) modules, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31293	19041-20000-51810	9600 N CALVIN AVE	91324	12	201B117   559	2761004016	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Issued	12/16/2019 12:00:00 AM	ADDRESS	34.24477	-118.55481	Plan check for Energy Storage System, Energy Storage system size: 13.5KWH. new Energy Storage Power wall 2.0 13.5KW, 1 new sub-panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31294	13041-20000-18066	1288 N ANGELO DR	90077	5	144B153   281	4357014006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.09339	-118.43608	SINGLE FAMILY DWELLING. NEW 600A RATED EQUIPMENT. PC FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31295	18041-20001-27353	5140 N LANKERSHIM BLVD	91601	2	171B173   743	2353005017	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.16412	-118.37398	09-13-2018 Changs to an approved set of plans, Changes include revised lighting fixture on floor plan, lighting i kitchen, employee area, and restroom under mezzanine are new, all other lights are existing. Changes has been clouded as delta 2. Plan check only, permit covered under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31296	18041-10000-45898	17231 W SHERMAN WAY	91406	6	183B133     8	2227016044	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.20136	-118.50861	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31297	15041-10000-06333	642 E 52ND PL	90011	9	108B205   245	5103005006	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.9949	-118.26422	PV1, INSTALL 3.9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(12) MODULES: SNPOWER 327 W ;(1) inverter: ABB PVI-3.8-OUTD-US--A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31298	10041-10000-22911	200 S SAN PEDRO ST	90012	9	129A213    85	5161022023	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	34.04904	-118.24164	Ti in an existing commercial building. Plan check is for T24 and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31299	15041-20000-02676	19134 W LEMAY ST	91335	3	180B121   260	2129020007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.19128	-118.55047	PV1 SFD. Using standard plan. TOTAL SYSTEM SIZE 6.2KW AC USING STANDARD PLAN. PC FOR MICROINVERTER SYSTEM. USING ENPHASE M215. 29 MODULES IN TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31300	19041-20001-34431	10945 W BLUFFSIDE DR	91604	2	162B173   267	2366021045	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	12/03/2019 12:00:00 AM	ADDRESS	34.14133	-118.36823	Expedite per appliant request Plan check for PV roof mounted system, PV system size: 247.32KW DC, 211.3KW AC with 687 PV Modules and 18 inverters(9 of 14.4KW and 9 of 9.9KW) connected to 1600A Service.One plan has 2 applications. 19041-20000-34431 and 19041-20000-34447	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31301	19041-10000-44733	4821 N LANKERSHIM BLVD	91601	2	168B173   395	2353025048	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	02/03/2020 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.15818	-118.37082	Energy PC only , Area of scope 1632sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31302	15041-20000-35230	23338 W SCHOENBORN ST	91304	12	192B093   387	2005017004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.2201	-118.636	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS IS 7.6KWac. (40) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-FRONIUS PRIMO# 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31303	10041-20002-05319	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM			PC Info Complete	08/23/2012 12:00:00 AM	ADDRESS	34.10137	-118.34182	Changes from previously approved plans.  Replace existing switchboards with new switchboards.  Plan check for power only.Note: approved plans submitted for reference only.*****new 5000A sevice; reconnect all existing switchboards*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31304	15041-10000-20096	12073-12075 W VENTURA PL	91604	2	165B165  1214	2368002013	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.14489	-118.39502	Title 24, plan check for energy. TI existing coffee shop to ice cream shop. total square footage is 1010.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31305	16041-10000-01451	800 S FIGUEROA ST 9TH FLR	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 9TH FLOOR. SCOPE INCLUDES NEW LIGHTING FOR CORRIDORS, AND RESTROOMS ON THE 9TH FLOOR. TOTAL AFFECTED AREA IS 1348 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31306	13041-20000-23538	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.10137	-118.34182	PC FOR T24 ENERGY ONLY. TOTAL AREA 18534 SQFT. COMMON AREAS OF HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31307	16041-20001-09233	13604 W SHERMAN WAY	91405	2	183B157    75	2328008074	(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.20102	-118.4293	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a 5-story 65 unit apartment building.System size: 14kW. Ungrounded system. (70) 275W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31308	18041-10000-16454	12330 W MONTAGUE ST	91331	7	204B165   245	2537014033	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.25466	-118.40144	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31309	13041-10001-34677	1200 S GRAND AVE	90015	14	126A207   138	5139023907	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			11/23/2015 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.03989	-118.26331	Change to approved set by modify the whole plan with new equipment ( including fire pump) added, Main scope involved with voltage drop and and AIC rating being revised on most of the panels.; Lighting plan also be moidfied. .FULL PLAN CHECK FOR  New 7 Story (5 Story over 2 Story Podium) Mixed Use Building w/ 287 Unit Apartment & Retail Building over two level parking basement. PROJECTED AREA FOR LIGHTING WORK IS APPOXIMATELY 344,451 SQ FT AREA. SERVICEbuilding permit under: 13010-10001-02721, DESCRIPTION LISTED AS 347 UNITS; ELECTRICAL PLANS WERE BASED ON CALCULATIONS FOR 300 UNITS (REFER TO SHEET 1E0.03 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31310	14041-10000-02542	13450 W MAXELLA AVE STE #270	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Closed	07/14/2014 12:00:00 AM	ADDRESS	33.98645	-118.44148	TENANT IMPROVEMENT FOR NEW 'RA SUSHI' RESTAURANT. PLAN CHECK FOR POWER AND ENERGY. NEW 225KVA XFORMER, NEW 800A MAIN DISTRIBUTION PANEL. 208Y/120V, 3PH,4WIRE, 800A. PROJECTED AREA IN LIGHTING WORK IS APPROX. 5343 SQ FT (4463 SQ FT INDOOR + 880 SF OUTDOOR). METHANE BUFFER ZONE. FIRE ALARM VARIANCE WAS FILED.NOTE: THIS PLAN WILL BE SUBJECTED TO 2011 NEC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31311	19041-10000-37744	601 N PERUGIA WAY	90077	5	141B149   226	4362003013	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/28/2020 12:00:00 AM	ADDRESS	34.08032	-118.44886	[EPLAN]PLAN CHECK FOR ROOF MOUTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 21 MODULES USING P400 OPTIMIZERS AND ESS(TESLA POWERWALL) CONNECTED TO EXISTING 800A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31312	12041-10000-18921	3429 W OLYMPIC BLVD	90019	10	129B193   235	5081032010	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.05282	-118.31276	Plan check new fire alarm system for 6 story condominium building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31313	11041-10000-25935	630 W HARRY BRIDGES BLVD Main Bldg	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	33.77068	-118.26868	LEVEL V METHANE MITIGATION SYSTEM FOR NEW ADMINISTRATION BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31314	10041-10000-14232	20750 W VENTURA BLVD	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM			PC Approved	09/02/2010 12:00:00 AM	ADDRESS	34.16638	-118.58506	New Fire Alarm system for the office building. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31315	11041-10000-09106	2403 E 1ST ST	90033	14	127-5A223 160	5180002017	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM			PC Approved	07/12/2011 12:00:00 AM	ADDRESS	34.0437	-118.2094	TI TO AN EXISTING RESTAURANT.  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK ONLY FOR EXPIRED PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31316	14041-20000-07634	17703 W CANDIA CT	91344	12	219B129   271	2601050042	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	34.29804	-118.51999	Roof mounted PV system with system size 10.25 KW, transformerless	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31317	17041-20000-10121	400 N MARINE AVE	90744	15	030B205  1269	7418014009	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	33.77446	-118.26314	PLANCHECK FOR POWER AND ENERGY. SERVICE UPGRADE TO 1200 AMPS. TENANT IMPROVEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31318	18041-20001-36968	20600 W BERGAMO WAY	91326	12	213B109   122	2701052008	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.27627	-118.58195	Revision to approved set of plans.  Miscellaneous SLD changes: autotransformer circuit wiring detail modified and MSP upgrade omitted.  Installation of 19.6 kWh energy storage system connected to (E) 7.6 kW rated inverter with energy storage capabilities.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31319	14041-20000-02124	3346 N LINDA VISTA TER	90032	14	142-5A235 189	5219011007	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Expired	03/02/2016 12:00:00 AM	ADDRESS	34.08469	-118.17185	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31320	13041-20000-18368	12930 W VENTURA BLVD	91604	2	165B161  1027	2385026024	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	34.14513	-118.41481	TI FOR CHANGE OF USE FROM RESTAURANT TO BEAUTY SALON. NO MAJOR CHANGE IN LOADS. TOTAL SQRFT 1246	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31321	14041-10000-23429	1538 W SUNSET BLVD	90026	1	139-5A209 237	5404020003	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Expired	09/27/2016 12:00:00 AM	ADDRESS	34.07619	-118.25656	Title 24 Plan check for indoor lighting on a TI  restaurant, first floor and  second floor; plan check based on 2008 standard code due to building permit submited before July 1st.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31322	17041-20000-32692	12318 W VENTURA BLVD	91604	2	162B165   251	2369002026	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.14284	-118.40154	Plan check for a fire alarm system for a commercial building. Fire alarm consists of (1) FACP and (33) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31323	19041-20000-04970	1849 S DUNSMUIR AVE	90019	10	126B177   749	5064004018	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.04186	-118.35658	pv1install roof mounted pv system sized 5KW AC interconnetced with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31324	15041-10000-38397	3650 W MARTIN LUTHER KING, JR BLVD 268 B-C	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	TI TO RETAIL TENANT. T-MOBILE. NEW LIGHITNG. PLAN CHECK FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31325	12041-10000-10845	3620 S MCCLINTOCK AVE	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.0213	-118.28935	PLAN CHECK POWER AND ENERGY FOR USC SGM LECTURE HALL #123. PLACE OF ASSEMBLY MORE THAN 100 OCCUPANTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31326	12041-20000-28950	5454 S CENTINELA AVE	90230	11	105B161   826	4220012021	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	PIN	33.98308742	-118.41076608	Install new 600 ampere service to supply new and existing panels.  Plan check for power only.  Scope of work is to install new panels and new circuits and some existing circuits.  T-24 lighting  was approved on application numbers : 12041-20000-12142, 12041-20000-23816.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31327	14041-10000-32416	6801 W HOLLYWOOD BLVD # D2-251	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Info Complete	03/16/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I. REMODEL OF (E) RETAILL SPACE    PLAN CHK IS FOR TITLE 24; inspection fee is paid under application #15041-10000-07177.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31328	19041-10000-53296	20608 W OAKSBORO CIR	91364	3	168A111    85	2174012026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.15462	-118.58215	(E-PLAN)NEW INSTALLATION OF 1 ENERGY STORAGE SYSTEM AND A PANEL OF 200 AMPS TO AN EXISTING SOLAR SYSTEM AND  SERVICE OF 200 AMPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31329	19041-10000-39749	1045 S BROXTON AVE	90024	5	132B149    52	4363024007	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.06163	-118.44658	Plan check for Fire alarm system in a theater. (1) Facp, (1) Communicator and (23) devices.BTRC office of finance clearance was cleared	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31330	18041-10000-28926	12807 W MATTESON AVE	90066	11	111B153   987	4236015022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.99858	-118.4393	NEW FIRE ALARM SYSTEM IN THE BUILDING WITH 51 FA DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31331	12041-20000-19647	8301 W BEVERLY BLVD	90048	5	138B173   395	5514009027	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.07623	-118.37013	Plan check for power and energy. TI to existing building. 3287 conditioned, 761 unconditioned, 7715 outdoor.  Inspector to verify proper phase connection of panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31332	14041-10000-13407	210 N AVENUE 21	90031	1	139-5A221   8	5447012018	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.07715	-118.22138	T24, Remove HID light fixtures and replace with new fluorescent fixtures. Total area15528 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31333	19041-10000-15254	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.06664	-118.46903	FULL PLAN CHECK FOR POWER AND ENERGY FOR REMODEL OF EXISTING CLASSROOM/GYMNASIUM . SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENT AND LIGHTING ON AN EXISTING DISTRIBUTION SYSTEM. TOTAL EFFECTED AREA 6610 SQFT NEW CONNECTED LOAD OVER 400 AMPS.BLD: 19016-10000-09358	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31334	18041-20001-22464	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.20696	-118.3417	08-01-2018 Changes to an approved set of  plans, changes include relocate fire alarm devices, number of fire alarm devices to remain the same. Changes apply to delta 1 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31335	14041-20000-03407	16820 W VENTURA BLVD 2ND FLOOR	91436	5	168B133   181	2289001031	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.15873	-118.49973	T24 FOR EXISTING NONHIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE 2ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31336	19041-20000-34175	20612 W WOOD ROSE CT	91326	12	219B109   549	2701102039	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.29537	-118.58286	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31337	17041-20000-15114	8500 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	Switchgear upgrade - replacement of main breaker and removal of distribution breakers for future tenant.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31338	19041-20000-50222	18125 W ABBEY ROAD	91335	3	177B125   108	2124017089	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.18489	-118.52823	Plan check for PV roof mounted system and Energy Storage System(ESS) installed in to existing PV system, adding PV System size: 7.59KW DC, 6.451KW AC with 23 PV Modules and 23 microinverters, 2 Energy Storage Tesla PowerWall 2.0.  ESS System size: 27KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31339	18041-20000-44029	1474 E 92ND ST	90002	15	094-5A211  45	6048001017	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	PIN	33.95297022	-118.24797128	PV1.  Install roof mounted grid tied PV system sized 5 kW AC interconnected with (N) subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31340	16041-20001-31783	11431 N CLYBOURN AVE	91342	7	213B173   312	2530023004	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.278	-118.374	PV1.  Install 13.08 kW roof mounted PV system on SFD's detached garage.  (40) modules with (2) 6kW rated central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31341	19041-20000-24855	20511 W DUMONT ST	91364	3	169-5A111  15	2166020001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.16063	-118.58076	Plan check for a PV1 roof-mounted PV system. System size is 10.08 kWdc/7.6 kWac and consists of (1) inverter, (32) modules, (2) load centers, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31342	19041-10000-28607	12825 W VENICE BLVD	90066	11	111B153   716	4245017001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Issued	07/25/2019 12:00:00 AM	ADDRESS	34.00009	-118.44128	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31343	15041-10001-01072	12534 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.97822	-118.412	(3/3/2015) CHANGES TO AN APPROVED SET OF PLANS.  CHANGE FROM UNDERGROUND SERVICE TO OVERHEAD SERVICE.  DELTA ONE REFLECT THE CHANGES DONE ON THE PLANS.Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant).Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31344	17041-10001-20480	835 W JEFFERSON BLVD UNIT#H	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. REVISED SERVICE FROM 480 TO 208. ALL LOADS NOW ON 208 PANEL. PC ONLY. PERMIT ALREADY COVERED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31345	12041-20000-25781	814 N TOULON DR	90272	11	126B133    72	4408014022	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2012 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.04408	-118.50973	Photovoltaic system with battery charger system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31346	17041-10001-04030	1441 W KNOX ST #500	90501	15	057B197   111	7351002029	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM			PC Info Complete	04/13/2017 12:00:00 AM	ADDRESS	33.85442	-118.29986	PC FOR T24 FOR NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31347	11041-10000-09002	600 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	NEW CONVEYOR BELT SYSTEM FOR ALASKA AIRLINES, TERMINAL 6, LAX.  SEE APPLICATION 11041-10000-04160 (E11LA00431) FOR REFERENCE.  FULL PLAN CHECK PER CUSTOMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31348	12041-10000-27905	16605 W SUNSET BLVD Ste 103	90272	11	129B121   673	4415006026	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Approved	11/20/2012 12:00:00 AM	ADDRESS	34.04774	-118.54391	T.I.  Existing restaurant occupying space # 103.  Remodel of the light fixtures.  Permit was already pulled for the work under 12041-10000-27610.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31349	11041-10000-08949	4915 S VERMONT AVE 1-49	90037	9	111B197  1017	5017027031	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	05/10/2012 12:00:00 AM	ADDRESS	33.99832	-118.29191	FIRE ALARM WITH  1 FIRE ALARM PANEL, 4 CONTROL PANELS, AND 182 DEVICES,  REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31350	16041-20001-38364	19360 W REDBRIDGE LANE	91356	3	159B117    43	2177045007	RA-1	South Valley	Encino - Tarzana	Tarzana	Yes	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM			PC Approved	11/08/2016 12:00:00 AM	ADDRESS	34.13538	-118.55418	Expedited per applicant request.Plan check for a PV1 roof-mounted system. System size is 12.7 kWac and consists of (2) inverters, (45) modules, (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31351	18041-20000-06725	16133 W VENTURA BLVD Suite 400	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.15675	-118.4847	Plan check for Title 24 only. Project site is a suite on the 4th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 3,077 sq. ft.Note: Building application has been generated under 18016-20000-04644	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31352	17041-10000-30071	9717 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	PIN	34.24624257	-118.53668453	PC FOR TI FOR A RESTAURANT FOR TITLE 24 ENERGY ONLYTOTAL AFFECTED AREA 1200 SQ. FT. SCOPE INCLUDES NEW CIRCUITS, LIGHTS AND RECEPTACLES.B# 17016-20000-12281	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31353	19041-10000-30218	8230 N TOPANGA CANYON BLVD	91304	3	192B101   625	2110001056	(Q)C1.5-1, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.05	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	02/20/2020 12:00:00 AM		Permit Finaled	10/01/2020 12:00:00 AM	ADDRESS	34.21937	-118.60575	PLAN CHECK FOR - INTERIOR TENANT IMPROVEMENT CHANGE OF USE FROM DRUG STORE TO GROCERY STORE (M OCCUPANCY) - TOTAL NEW CONNECTED LOAD IS APPROX 750A TO EXISTING 1000A SERVICE AT 120/208 3PHASE 4 WIRE. TOTAL AFFECTED AREA = 15812 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31354	14041-20000-27521	7170 W SENALDA ROAD	90068	4	153B181   145	5572035012	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.11669	-118.34607	PV1.  Install 9.6 kW roof-mounted, utility-interactive PV system.  Microinverters.  400A-rated service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31355	13041-20000-01992	8000 W OCEANUS DR	90046	4	153B173   924	5569030005	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2013 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.1121	-118.36951	Roof mounted P.V. system (12.5 Kdc) for single family dwelling using microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31356	17041-20000-16704	23856 W STAGG ST	91304	12	189B089   448	2027040034	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.21056	-118.64918	Plan check for a PV1 roof-mounted PV system. System size is 13.5 kWac and consists of (39) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31357	14041-10001-12638	823 S MARIPOSA AVE	90005	10	132B197   604	5094018013	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.05705	-118.2989	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL  2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER AND WITH OPTIMIZERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31358	10041-10000-03936	13069 S KIYOT WAY	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/22/2010 12:00:00 AM	PIN	33.97159161	-118.42340103	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31359	13041-10000-18249	2819 W FLORENCE AVE	90043	8	102B189  1274	4008025027	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	33.97473	-118.3243	Auto body shop TI.  Replacement of fire-damaged lighting fixtures as per applicant.  Title 24 plan check only.  Full plan check subject to inspection based on hazardous classification.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31360	16041-10000-21251	10012 N COZYCROFT AVE	91311	12	204B109   464	2741024009	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.25206	-118.58183	PV1 INSTALL NEW 3120 W DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FMILY HOUSE.(12) MODULES: HYUNDAI HIS-S260RG 260W(12) MICROINVERTERS: ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31361	17041-20000-14137	5747 N RHODES AVE	91607	2	174B165   283	2340014009	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.17522	-118.40321	PV1.  Install 15.2 kW roof mounted grid tied PV system.  (57) modules with (2) inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31362	18041-30000-20877	1741 N NAUD ST	90012	1	136-5A219  62	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	10/22/2019 12:00:00 AM		Issued	10/22/2019 12:00:00 AM	ADDRESS	34.06939	-118.22538	FULL PLAN CHECK FOR ADDITION AND CHANGE OF USE FROM WAREHOUSE TO NIGHTCLUB (A-2). NEW 1600A DIST. BOARD, (6) NEW PANELBOARDS, (4) TEATHRICAL LIGHTING CABINETS, AND POWER/LIGHTING LOADS(B# 18014-20000-01810)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31363	19041-10000-19982	1335 S ABBOT KINNEY BLVD	90291	11	108B145  1240	4239027009	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	33.99097	-118.46678	Energy plan check for an INTERIOR T.I. FOR (E) RETAIL STORE. Scope includes new lighting and equipment with a total lighting area of 1681-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31364	18041-20000-34000	555 S FLOWER ST 13th flr	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	ti to an existing commercial building (high rise).  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31365	18041-20000-25384	17019 W DEARBORN ST	91325	12	198B133   461	2692021025	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Re-Activate Permit	08/01/2019 12:00:00 AM	ADDRESS	34.23749	-118.50319	Plan check for a PV1 roof-mounted PV system. System size is 12.2 kWdc/10.8 kWac-CEC and consists of (2) inverters, (40) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31366	12041-20000-03927	4601 N ARRIBA DR	91356	3	168B121   428	2176024014	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.15466	-118.54221	pv system single family 8kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31367	17041-30000-37789	864 S ROBERTSON BLVD	90035	5	132B169   100	4333015025	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			10/19/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.06106	-118.38339	Plan check for new fire alarm system 3 story existing office building. Toal fire alarm devices: 79 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31368	13041-20000-19114	13511 W RAND DR	91423	5	162B157   355	2373023004	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.14187	-118.42701	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 1.7 KW. USING 8 MICROINVERTER, ENPHASE M215. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31369	15041-10000-41798	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.08901	-118.34188	NEW 6 STORY MEDIA PRODUCTION BUILDING. THIS IS CORE AND SHELL. PC FOR POWER AND ENERGY. NEW 2500A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31370	15041-20000-18165	12905 W VENTURA BLVD	91604	2	165B161   996	2375022050	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.14536	-118.41396	TI to existing commercial building (restaurant). Plan check for power and energy. Adding new 600A service. Adding new lighting including emergency. Total sqft. 2,087.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31371	18041-20001-14334	6822 W PARSONS TR	91042	7	207B201    23	2553014002	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	9800.26	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.26631	-118.28268	Expedite for solar.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31372	14041-20001-28146	16501 W VENTURA BLVD Ste 615	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.1578	-118.49275	THIS IS CHANGES TO APPROVED SET OF PLANS. RECHECK ALL ENERGY. INCLUDING CONTROLLED RECEPTACLES. TI to (E)  commercial office space in existing commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31373	13041-10000-33595	1415 S LINCOLN BLVD	90291	11	111B145  1262	4241008016	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	33.99749	-118.46027	Minor tenant improvements for Chase Bank for office and workstation areas.  Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31374	12041-20000-27265	1820 N WESTRIDGE ROAD	90049	11	135B137   241	4426009024	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.06722	-118.49748	Photovoltaic sytem on roof of single family dwelling with service upgrade to 400 amperes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31375	13041-10000-24717	14722 W MAGNOLIA BLVD UNIT 4	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	PV2.  Install 1.92 kW DC roof-mounted photovoltaic system, interconnect with multifamily building panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31376	18041-30000-08100	1180 S BEVERLY DR Suite 200	90035	5	132A167   177	4330031026	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.05581	-118.39554	Plan check for Title 24 only in existing space. T.I. office space. Total area:  3320SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31377	13041-10000-15826	11111 W SANTA MONICA BLVD SUITE 2170	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	Office TI to highrise building in suite 2170, replacement of devices to building standards.  New interior lighting and demo'd partitions.  5,753 sq ft.  Newly connected load less than 400A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31378	18041-20000-46845	5324 N GENESTA AVE	91316	5	171B133   778	2258007166	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.16802	-118.50313	Plan check for PV roof mounted system, System size: 17.38kW DC STC, 12.76kW AC with 44 PV modules and 44 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31379	19041-20000-06891	959 N SEWARD ST 3rd Floor	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	T24 PLAN CHECK TO 3RD FLOOR CORRIDOR OF EXISTING COMMERCIAL BUILDING. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1,884SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31380	12041-10000-13253	865 N SANBORN AVE	90029	13	144A201   301	5427004005	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	Apartment			06/07/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.0879	-118.284	PLAN CHECK FOR NEW 3- STORY 11-UNIT APARTMENT WITH GARAGE WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31381	19041-10000-12796	12220 W FOOTHILL BLVD	91342	7	213B165   318	2532001011	[T][Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.04	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.28131	-118.40272	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31382	18041-30000-04679	137 N DOHENY DR 1-5	90048	5	138B169   227	4335006027	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	05/25/2023 12:00:00 AM	ADDRESS	34.07637	-118.39	Plan check for fire alarm system in 5 units  5 story appartment. Total fire alarm devices: 63 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31383	19041-10001-14647	4203 W JEFFERSON BLVD	90016	10	120B181   692	5050025058	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.0257	-118.34196	(PC Only) Change to an approved set by removing the transformer from the plan. All changes under delta-2 and 3 only.(((PC for power and energy for new Brewery and testing room. New 450A,120/240v,3ph, 4w Feeder to feed new place. total lighting area of  the scope is 2,000SF.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31384	13041-10000-18741	701 N GRAND AVE	90012	1	135A213   335	5407012017	R4-1	Central	Central City North	Historic Cultural		2071.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.06269	-118.24347	PV1.  Install 4.16 kW AC roof-mounted solar array, interconnect into main service panel.  {16 modules: Renesola JC260M-24/Bb} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31385	10041-10000-05033	4810 W SUNSET BLVD	90027	13	147B197   737	5543017018	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/19/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.09792	-118.29436	PLAN REVIEW FOR  AS-BUILT-PLANS   SHOWING NEW FEEDER  TO EXISTING SIGN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31386	18041-10000-34770	424 S LOS ANGELES ST #4	90013	14	129A213   285	5148007005	C2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Issued	09/12/2018 12:00:00 AM	ADDRESS	34.04664	-118.24676	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31387	12041-10000-08438	12930 W VENTURA BLVD	91604	5	165B161  1027	2385026024	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.14513	-118.41481	T.I. to restaurant, change from Baja Fresh to Five Guys Burgers.  Less than 400A of load and the occupancy load is 71, per applicant.  Full Plan check for Power and Energy, requested by the applicant.   Applicant has a pre-cut check, additional fees for 2,300 of T-24 will need to be collected.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31388	16041-10000-23440	20040 1/2 W VENTURA BLVD	91364	3	174B113   598	2166043006	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.171	-118.56999	PC FOR RESTAURANT TI. NEW LIGHITNG WILL BE PC FOR T24 ENERGY ONLY. PERMIT WILL BE ISSUED FOR PANELS AND RECEPTACLES AS REQUIRED BY CONTRACTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31389	16041-10008-01886	700-800 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 40 ON PLANS. ADDITION OF CIRCUITS AND PANEL(S). UPDATED FLOOR PLANS TO MATCH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31390	13041-10000-32947	17819 W SIDWELL ST	91344	12	219B129   652	2601071004	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.3004	-118.52266	PV1, Install  9.75 kw DC roof-mounted solar array for a 2 story house, interconnect with main service panel.Transformered inverter: Sunny Boy SB8000US-12. 39 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31391	14041-10000-35805	610 W CHILDS WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.01886	-118.28247	NEW FIRE ALARM SYSTEM FOR A new 5-story multi-use building for USC school.  9 FA CONTOL PANELS, 745 FIRE ALARM DEVICES AND FA PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31392	12041-10002-23021	4301 W 3RD ST	90004	4	135B193   200	5517007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Closed	04/07/2014 12:00:00 AM	PIN	34.06916769	-118.30825671	"][][changes made to approved set of plans; changes is for added 125A/3P CB in main ""MSB"", upsized inverter from 30kva to 75 kva, revised load calcs to account for the upsized T1 xformer. Added panel ""LP"" for reference only ""[][][]CHANGES MADE TO A SET OF APROVED PLANS; THE ADDITION OF EF-7 AND POWER FOR DOOR STRIKES, REMOVED AC UNIT AND REMOVED ONE EV CHARGER; NOT INCLUDING LOW VOLTAGE AND CAMERAS ADDITIONS IN THE SCOPE OF PLAN CHECK , ALL CHANGES ARE CLOUDED ON PLANS, PL, 7-26-13[][][][]NEW CONSTRUCTION FOR A MULTI LEVEL PARKING GARAGE. EPC IS FOR POWER AND ENERGY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31393	19041-20000-34180	20619 W BLUEBIRD CT	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.29712	-118.58294	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31394	17041-10000-44209	957 W 88TH ST	90044	8	096A199   108	6038010902	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			12/08/2017 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	33.95803	-118.29064	NEW 4 STORY, 41 UNIT APARTMENT BUILDING. SCOPE INCLUDES ADDING A NEW 1600A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD. TOTAL AFFECTED AREA IS 32271 SQ. FT. B#17010-10000-02542	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31395	16041-10000-39881	1945 S FIGUEROA ST	90007	9	124-5A205 271	5126003024	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.03334	-118.2731	METHEANE (LEVEL3) MITIGATION AND METHEANE DETECTION SYSTEM. COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31396	18041-10000-22583	333 S HOPE ST 33rd FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Power and Energy on (E) office. TI with new loads > 400A, total area: 22,907 sq.ft. 33rd floor.(B# 18016-10000-18297)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31397	16041-20000-22141	11950 W LOPEZ CANYON ROAD	91342	7	216B165    24	2526003909	OS-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.28787	-118.40055	PLANCHECK FOR POWER ONLY. INSTALLATION OF NEW EQUIPMENT) ( CHILLER AND SKID ) IN LANDFILL GAS PROCESSING AREA. HAZARDOUS CLASS 1 DIV 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31398	19041-20001-22385	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	08-09-2019 Changes to an approved set of plan, changes include reduce scope of work. All changes has been clouded as delta 2. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31399	16041-20000-28190	11734 W HAMLIN ST	91606	2	180B169   892	2322017033	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.18865	-118.38909	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (19) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31400	16041-10005-16336	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	Change to approved set by removing portion of the scope of work from the plan mainly ground, sixth and seventh floor for different application (19041-10000-01803). Minor changes also being adjusted on the floor plan. All changes under delta-16 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31401	14041-10001-24588	301 N ALMA REAL DR	90272	11	123B129   327	4411020022	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.03397	-118.5242	"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 4.5KW DC. "" THE SOLAR PV INSTALLATION SHALL COMPLY WITH LOS ANGELES FIRE DEPARTMENSTS FIRE PREVENTION BUREAY (FPB) REQUIREMENT NO. 96 OR APPROVED PLANS BY THE LAFD""MAIN SERVICE 400 AMPS.(16) ENPHASE M215 MICROINVERTER(16) SOLARWORLD SW 250"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31402	17041-20000-17737	304 S BROADWAY	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.05076	-118.248	New fire alarm system for (E) commercial historic building - (195) new devices with (N) FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31403	13041-10000-03492	2130 E 1ST ST	90033	14	127-5A223 122	5183008901	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.04433	-118.21291	PLAN CHECK FOR TITLE 24 IN EXISTING BUILDING (NOT A FIRST TIME TENANT). 6164 SQUARE FEET. SCOPE OF WORK < 400A. NOTE: ALL TITLE 24 PART 6 ENERGY PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31404	14041-20000-27682	5334 N OVERING DR	91367	3	171B089   136	2047018016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Expired	12/14/2016 12:00:00 AM	ADDRESS	34.16722	-118.64765	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 12kW.(2) Aurora PVI-6000TL-OUTD-S-US-A transformerless inverters(40) Sun Power SPR-E20-327 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31405	12041-20000-28880	17461 W VENTURA BLVD	91316	5	171B129   410	2257016054	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.16157	-118.51326	Service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31406	19041-10000-03150	355 S GRAND AVE #2800	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.05191	-118.2525	ENERGY PLAN CHECK FOR AN OFFICE (SUITE #2800) TENANT IMPROVEMENT TO AN EXISTING HIGH RISE BUILDING;  SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 7,117-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31407	19041-10000-41085	5721 S WESTERN AVE	90062	8	108B193  1120	5005032038	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.99046	-118.30913	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITSINDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31408	13041-10000-30653	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	Building 2 of 5:  BONUS RANGE. UPGRADED NEW ELECTRICAL SERVICE, NEW PANELS, NEW TRANSFORMERS, NEW CONVENIENCE  RECEPTACLES. FEES TO BE VERIFIED BY PLANCHECKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31409	12041-20000-30656	16701 W LOS ALIMOS ST	91344	12	207B137   311	2683019009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	02/04/2013 12:00:00 AM	ADDRESS	34.2657	-118.49564	Enphase system on roof of single family dwelling with PV subpanel, and service main circuit breaker reduction from 200 to 175 amperes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31410	13041-20000-25872	810 E PICO BLVD 4th Floor	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Expired	09/19/2016 12:00:00 AM	ADDRESS	34.03119	-118.25079	T24 FOR EXISTING MALL 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31411	16041-20000-43289	4376 N BECK AVE	91604	2	165B169   365	2365018016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/31/2016 12:00:00 AM	ADDRESS	34.14948	-118.38322	pv1install roof mounted pv system sized 5kw interconnected wtih msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31412	17041-10001-30180	5880 W JEFFERSON BLVD	90016	10	120B173   380	4205027011	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.02238	-118.37681	PC FOR CHANGES TO APPROVED SET, NOTE CHANGE ON CLOUDED AREAS. SCOPE INCLUDES REVISIONS TO LIGHTING IN BREAKROOM AND T-24 FORMS. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31413	19041-10000-08486	8953 N LINDLEY AVE	91325	12	195B125   239	2769015035	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.23331	-118.52753	*ePlan* Permit fee zero dollar per AB 1414 / SB 1222.PV1. 49 roof mounted PV solar panels (Hanwha QCell Q.Peak-G4.1 305) with 14.945 kW DC/12.6 kW AC system and 225A main service panel upgrade. Panel upgrade to be permitted seperately.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31414	13041-10000-24724	13224 W FERNMONT ST	91342	7	222B157   295	2512006042	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.30504	-118.42122	PV1.  Instal 5.88 kW DC roof-mounted solar array of 24 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31415	11041-10000-05847	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM			PC Approved	07/15/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	Existing starbucks , part of high rise , existing exit sign, title 24 , existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31416	18041-10000-27605	1664 S WESTERN AVE	90006	10	126B193   438	5074014025	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.04269	-118.30885	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31417	19041-20001-44418	15430 W GREENLEAF ST	91403	5	166-5A145  35	2283018026	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.15244	-118.4705	$0 PLAN CHECK AND PERMIT FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. PV SYSTEM SIZE CHANGED TO 17.01 KW DC/15.62 KW AC. ADDITION OF (6) PV MODULES AND OPTIMIZERS, UPGRADING A 5KW INVERTER TO 7.6 KW, AND UPGRADING A 225A LOAD CENTER TO 400A. CHANGES MADE TO SINGLE LINE DIAGRAM AND ROOF LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31418	19041-10000-28013	3317 S SHELBY DR	90034	5	123B165  1467	4316030011	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Issued	07/29/2019 12:00:00 AM	ADDRESS	34.0319	-118.40159	[EPLAN] PLAN CHECK FOR INSTALLATION OF 2 NEW TESLA POWERWALLS CONNECTED TO EXISTING PV SYSTEM. SCOPE INCLUDES NEW 200A LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31419	19041-30000-45387	5005 N FIGUEROA ST	90042	1	150A225   181	5468004009	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.10525	-118.20211	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI. SCOPE OF WORK INCLUDES NEW LIGHTING, NO NEW CIRCUITS, TOTAL AFFECTED AREA  IS 669 SQFT. ((B#19016-10K-23135)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31420	13041-10001-24710	3320 S KERCKHOFF AVE	90731	15	006B197   302	7467004044	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	33.71382	-118.28961	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31421	17041-20000-44099	1320 N VINE ST	90028	13	147A189   220	5546020012	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.0951	-118.32645	Plan check for energy only. TI to restaurant. Replacing existing lighting with new fixtures in place - 1,207sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31422	15041-20001-20901	16545 W LASSEN ST	91343	12	201B137   139	2678026001	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM			PC Approved	07/22/2015 12:00:00 AM	ADDRESS	34.25035	-118.49297	Expedite per applicant request[[[[Plan check PV tri-plex unit system. System size: 3.0kW. Each unit is rated to 200A]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31423	19041-10000-38449	13601 W HARTLAND ST	91405	2	183B157   838	2328012021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.195	-118.42899	[eplan] plan check for Roof mounted 12.418 kW DC/12.3kva pv1 consisting of 39 Sunpower modules with 39 Enphase IQ7X microinvertersmain breaker derating under separate permitFees $76.35 is due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31424	14041-20001-29629	9100 W ORIOLE WAY	90069	4	147B169   812	5560006024	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM			PC Approved	11/04/2014 12:00:00 AM	ADDRESS	34.09672	-118.38821	Fee for Expedite only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31425	17041-30000-44124	11800 W WILSHIRE BLVD	90025	11	129B145   804	4263007123	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	11/04/2021 12:00:00 AM	ADDRESS	34.04771	-118.46271	Plan check for the addition of fire alarm devices, RPSs, and annunciator to an existing fire alarm system. Addition includes (246) devices, (1) annunciator, and (4) RPSs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31426	11041-10000-25243	410-412 1/2 N LA CIENEGA BLVD	90048	5	138B173    27	5514001011	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM			Corrections Issued	12/17/2011 12:00:00 AM	ADDRESS	34.07843	-118.37638	REMODEL (E) 2 STORY COMMERCIAL BLDG, NEW FACADE, NEW ROOF STRUCTURE, NEW PLUMBING, ELEC & HVAC, NEW WINDOWS, NEW ROOF ACCESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31427	17041-20000-11993	341 S BERENDO ST	90020	10	135B197   396	5502006024	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.06786	-118.29431	permit fees $0.00 by state senate bill no.1222pv2install roof mounted pv system sized 32kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31428	19041-10000-02569	5901 W CENTURY BLVD 400	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Issued	01/22/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	Istalling additional devices to an existing Fire Alarm System on the 4th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31429	13041-10000-34389	7515 N ZOMBAR AVE	91406	6	186B145   300	2222014031	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.20706	-118.46741	PV1, install 6 kw DC roof-mounted solar array for a 2-story house with power optimizers, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE6000A-US. (24) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31430	11041-20000-11843	17107 W VENTURA BLVD	91316	5	168B133    17	2258012028	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.16046	-118.50575	T.I.  for Chase Bank.  Renovating light fixtures.  Plan heck is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31431	14041-10000-08251	1019 E 4TH PL	90013	14	127-5A217  60	5163018003	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Expired	04/14/2020 12:00:00 AM	ADDRESS	34.04195	-118.23327	UPGRADING EXISTING SERVICE TO 600A FOR WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31432	14041-20000-07837	17139 W VENTURA BLVD # A	91316	5	171B133   703	2258012025	(Q)P-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.16059	-118.50671	Change of use from retail to medical office.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31433	12041-20000-05645	14860 W ROSCOE BLVD 200	91402	6	192B149   420	2210003075	R1-1, R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20, 1201.02	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.22131	-118.4572	Provide 100 A disconnect for X Ray contol panel, modification of lighting in the room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31434	17041-10000-15738	10250 W SANTA MONICA BLVD STE. 2440	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan check for UCLA medical office located in Westfield Century City Ste#2440. Total area: 3,134 sq.ft, fed from MS-ELA11	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31435	12041-20000-17876	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.24205	-118.59773	T.I. to existing building of the office area.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31436	18041-10000-33099	701 W CESAR E CHAVEZ AVE 102	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Los Angeles Historic Cultural		2071.01	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.06107	-118.24412	FULL PLAN CHECK (POWER+ENERGY) FOR TI AND CHANGE OF USE FOR EXISTING SPACE FROM RETAIL TO GYM. EXISTING DISTRIBUTION BOARD AND EXISTING PANELS, AND ADD (2) NEW PANELS, NEW LIGHTING AND POWER. TOTAL AREA: 29,607 SQ.FT(B# 18016-10000-27807)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31437	12041-20000-20928	20455 W SORRENTO LANE	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/05/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM				New 3 level 43 unit apartment building.  Identified as building type A on the plan.  A variance to separate the electrical and fire alarm plan check is required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31438	18041-10000-27161	317 N EUBANK AVE #2	90744	15	030B209  1063	7424003036	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.77379	-118.25433	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31439	17041-10001-44607	15223 W LASSEN ST	91345	7	201B145   183	2660011011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.25016	-118.46394	Supplemental for changes to approved set. PC FOR ROOF MOUNTED PV ON SFD.SYSTEM SIZE 5.51KWDC/ 5.0KWACSCOPE INCLUDES 19 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.  %% ZERO PV FEES DUE TO SENATE BILL 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31440	19041-10001-43252	1804 S COCHRAN AVE	90019	10	126B177   336	5067020003	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.04403	-118.35378	"DELTA ""1"" Changes to approved plans for relocating PV Panels on the roof. The total number of panels did not change, but the central inverter size went from a SE3000H-US to a SE3800H-USPV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3KWac/4.060KWdc. SCOPE OF WORK INCLUDES 14 MODULES (HYUNDAI HIS-S290RG) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE3000H-US)."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31441	14041-20000-24549	21555 W OXNARD ST Floors 1,2-, 4, and 5	91367	3	177B105    33	2146005177	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.17943	-118.59939	Plan check for energy only. Add lunch/break rooms to existing high rise office building on floors 1,2,4 and 5. New lighting, including emergency. 2,568sqft. PERMIT UNER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31442	13041-10002-15767	430 S BROADWAY	90013	14	129A211    57	5149024008	[Q]C4-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM			PC Approved	12/29/2014 12:00:00 AM	ADDRESS	34.04864	-118.24991	"REVISIONS TO LIGHTING SYSTEM FOR THE GARAGE, CORRIDORS, AND SUPPORT AREASPLAN CHK IS FOR TITLE 24conversion of retrofit building to 58 UNIT MIXED USED BUILDINGATTACHED TO THE PLANS ARE MODIFICATIONS OF BUILDING ORDINANCES FOR THE BUILDING TO KEEP ITS ""NON-HIGH RISE STATUS"" MODIFICATIONS WERE DATED May 9th 2013 and signed by Jameson Lee"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31443	12041-10000-10646	2970 W OLYMPIC BLVD #303	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	Plan check power and energy for new medical office, first-time tenant. Suite #303. Not checked for OSHPD 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31444	17041-10001-42365	7150 W MELROSE AVE	90046	5	141B181   640	5525015001	C2-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.08327	-118.34527	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD CONDITIONS. SCOPE INCLUDES NEW CIRCUITS FOR ADDITIONAL EQUIPMENT. ADDITIONAL PERMIT FEE TO BE COLLECTED FOR EQUIPMENT AND CIRCUITS. B# 17016-10000-34819	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31445	16041-20000-17390	4225 N ETHEL AVE	91604	10	165B161   836	2375016030	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.14679	-118.41845	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 48KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31446	13041-10000-03393	200 WORLD WAY Terminal 2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	33.94558	-118.4039	Upgrade to existing fire alarm system for LAX at Terminal #2. Counted ALL devices as NEW devices per CUSTOMER request. NO REFUND WILL BE GIVEN. Existing fire alarm panel with 1561 devices.PLAN CHK AND PERMIT WAS OBTAINED ON 11041-10000-27300; ORIGINAL CONTRACTOR HAS TRANSFERED PERMIT TO NEW CONTRACTOR. REVIEW IS FOR PLAN CHK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31447	18041-20000-46595	12137 W MONTAGUE ST	91331	7	204B165    64	2537002017	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM			Reviewed by Supervisor	01/10/2019 12:00:00 AM	ADDRESS	34.25779	-118.39756	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade. Work includes a 3,000 amp service and downstream distribution equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31448	14041-10000-30851	16122 W RUNNYMEDE ST	91406	6	186B141   427	2205024020	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.2056	-118.48444	Energy plan check for a commercial building by replacing HID fixture to new LED lighting fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31449	19041-10000-43392	2237 S HARVARD BLVD	90018	8	123B193   293	5058018028	[Q]RD2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	07/18/2020 12:00:00 AM	ADDRESS	34.03502	-118.3068	Remove HID fixtures and replace with new LED fixtures -T/24 only. Outdoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31450	14041-10000-09280	1605 N GLENDALE BLVD	90026	13	142-5A209 200	5423009026	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.08393	-118.26031	Raze and rebuild Arco convenience store, canopy, UST'S and adjacent pavement. (Job was approved before and expired. The approve set submitted for reference only.) PERMIT TO BE PULLED UNDER INSPECTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31451	17041-20001-23699	5021 N MONTEZUMA ST	90042	1	151-5A225  85	5469009039	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.11089	-118.20564	EXPEDITED PER APPLICANTS REQUEST.INSTALLATION OF ENERGY STORAGE SYSTEM + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.3 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31452	18041-20001-20197	5939 N CANOGA AVE	91367	3	177B105    87	2146006052	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.17815	-118.59772	08-08-2019 Changes to an approved set of plan, Changes incloude addtion of area PD Training room. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31453	15041-10001-38121	11704 N PRAGER AVE	91342	7	213B165   196	2531026047	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Expired	03/02/2018 12:00:00 AM	ADDRESS	34.28268	-118.3963	Supplemental PC and changes to an approved plan . Revised rooftop module layout, added 125A load center, changed the orientation of the electrical equipments <<PV1, INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (16) MODULES:HANWHA Q CELLS Q-PRO BFR-G4 260(16) MICROINVERTER: ENPHASE ENERGYM215-60-2LL-S22>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31454	10041-10000-03276	333 S ALAMEDA ST #101	90013	9	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM	03/15/2010 12:00:00 AM		Permit Finaled	06/30/2010 12:00:00 AM	ADDRESS	34.04448	-118.23824	"Plan check T-24 Energy for TI ""Boong Uh Town"" Suite #101."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31455	14041-20000-10172	4700 W SUNSET BLVD FLR 3, 4	90027	13	147B197   729	5543013002	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.09788	-118.29194	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT - REMODEL EXISTING EXAM ROOMS/OFFICES TO WAITING ROOM, OFFICES AND CONFERENCE ROOM ON 3RD AND 4TH FLOORS OF EXISTING MEDICAL OFFICE BUILDING. NO PATIENT OR CRITICAL CARE ACCORDING TO APPLICANT.(1,369 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31456	11041-20000-25688	7901 N VENTURA CANYON AVE	91402	6	189B157   570	2214026025	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Apartment			12/02/2011 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	07/15/2013 12:00:00 AM	ADDRESS	34.21406	-118.42891	New 30 unit apartment building.  A variance to separate the fire alarm has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31457	12041-10003-13375	505 S VIRGIL AVE	90020	13	135B197   873	5077004028	R4P-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.0649	-118.28724	"((DELTA 4 CHANGES MADE TO PREVIOUSLY APPROVED PLANS). CHANGES MADE TO pages e-10,11,12 to emergency lighting to put circuits on the same as general lighting or lock-on device((DELTA 3 CHANGES MADE TO PREVIOUSLY APPROVED PLANS (BY P.U.). CHANGES MADE TO FLOOR PLAN. ADDITIONAL 3 PANELS W/ NEW CIRCUITS. METHANE ZONE))PLAN CHECK POWER AND ENERGY FOR EXISTING THREE STORY BUILDING.  CHANGE OF USE TO MEDICAL BUILDING. TWO  2000A SERVICES SUPPLYING BUILDING IN METHANE ZONE. ""COMPLY WITH DEPARTMENT ORDER effective date11/30/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31458	15041-20000-40279	9926 N NITA AVE	91311	12	201B101    64	2745006017	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.25082	-118.61352	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (27) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31459	15041-10000-41282	6122 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.09782	-118.32333	Change of use from retail to restaurantplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31460	18041-10000-34660	6150 N LAUREL CANYON BLVD BLDG J	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	PLAN CHECK FOR FIRE ALARM SYSTEM FOR BUILDING J CONSISTING OF 255 DEVICES AND TYING TO FIRE ALARM PANEL LOCATED AT BUILDING H PER FIRE DEPARTMENT AND CONNECTING BRIDGE. BUILDING H INSPECTION FEES HAVE BEEN PAID FOR IN APPLICATION # 18041-10000-32127 / E18LA03750	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31461	15041-10000-18760	7215 W MANCHESTER AVE	90045	11	096B157   554	4114034031	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	33.95998	-118.41998	ALTERATIONS IN A BANK OF AMERICA  BRANCH OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31462	16041-10000-09267	11300 W OLYMPIC BLVD	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.03792	-118.44134	PC FOR ENERGY ONLY. T.I FOR A 5-STORY COMMERCIAL BUILDING (ELEVATOR LOBBY). TOTAL AREA 635 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31463	13041-10001-05365	3937 S 6TH AVE	90008	8	117B189  1537	5034007010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Expired	09/10/2015 12:00:00 AM	ADDRESS	34.01325	-118.32424	(((changes to approved set of plans: added 4 modules and changed PV module type to ET-P660255 255W. Charged fees per applicant request)))2.45 KW SOLAR INSTALLATION {10 MODULES: REC 245 PE BLK} {MICROINVERTERS: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31464	18041-10000-43090	1001 E 14TH ST	90021	14	123A211   301	5132018014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.03002	-118.24983	Energy plan check for a change of use from a warehouse to manufacture with new light and equipment that cover a total area of 4000-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31465	17041-20000-04837	6431 N INDEPENDENCE AVE	91367	3	180B109   592	2149003039	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.18737	-118.59079	Resubmittal of design plans due to lost set of plans/partial redesign of system.  Original permit issued under 16041-20000-23265.  Reduction of number of 15kW rated central inverters from (5) to (4).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31466	14041-20000-16602	3411 E ESTRADA ST	90023	14	120A225   371	5190017037	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.02081	-118.20481	PV1Install a roof mounted solar array on a SFD. System size: 6kW(1) PowerOne PVI-6000-OUTD-US transformerless inverter(20) SunPower 327W pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31467	18041-10000-34201	9350 N RESEDA BLVD	91324	12	198B125   168	2764011029	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.24046	-118.53589	REPLACE INDOOR FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS- T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31468	10041-10001-13974	2051 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	09/28/2010 12:00:00 AM	ADDRESS	34.03969	-118.44283	TI IN RETAIL STORE.  ; PLAN CHECK  FOR T-24 ENERGY  was obtained on 10041-10000-12984; this supplement application is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31469	13041-20000-28266	5961 N LUBAO AVE	91367	3	177B113   131	2153003022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.17929	-118.56748	PV1 SINGLE FAMILY DWELLING. roof mount SYSTEM. NO SOLAR CAP APPLICABLE. TOTAL SYSTEM SIZE 10KW AC USING 2 TRANSFORMERLESS INVERTERS AND 30 MODULES. 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31470	12041-10000-24931	20200 S WESTERN AVE	90501	15	054B193   700	7351021038	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	33.84769	-118.30905	TI IN AN EXISTING COMMERCIAL TESTING / OFFICE AREA. INSTALL NEW LIGHTS AND LESS THAN 400 AMPS OF LOAD. PLAN CHECK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31471	15041-20000-04700	1649 W 58TH ST	90062	8	108B193  1171	5003030027	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	33.98982	-118.30623	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel. (22) Sunpower 327W Modules(2) PVI 3.8 TL Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31472	15041-10000-37169	542 N HARKER ST	90731	15	018B201   139	7449002006	R2-1XL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	33.74774	-118.2866	PV1 INSTALL 1.855 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (7) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31473	17041-20000-12984	910 W BLOOM WALK 3RD FLOOR	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Issued	06/13/2017 12:00:00 AM	ADDRESS	34.01974	-118.28885	3578 SF  TENANT IMPROVEMENT IN EXISTING LIBRARY BUILDING - 3RD FLR.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31474	13041-20000-36040	19300 W RINALDI ST #M	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Expired	10/27/2014 12:00:00 AM	ADDRESS	34.27414	-118.55457	Change to lighting in an Existing Retail Space.  Load is less than 400 amps per the applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31475	18041-20000-39228	642 N WESTERN AVE	90004	13	141B193   686	5521001004	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM			PC Info Complete	10/12/2018 12:00:00 AM	ADDRESS	34.08285	-118.30895	Plan check for Power only in existing building 800A Service, 1 transformer and distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31476	14041-20000-30337	22710 W ECCLES ST	91304	12	192B097   202	2004003003	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.22276	-118.62163	PV1 SFD. TOTAL SYSTEM SIZE 5.5KW AC USING 22 MODULES. USING MICROINVERTER SYSTEM USING ENPHASE M250. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31477	13041-10001-34527	219 W 92ND ST	90003	8	094-5A203 227	6040036006	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	33.95292	-118.27661	Expedited RSES plan check per applicant request.{{PV1, Install  2.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (11) modules[TRINA SOLAR # TSM-250PA05.18] on a 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31478	19041-10000-34250	17864 W VENTURA BLVD	91316	5	171B129   288	2182002012	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	12/15/2020 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.16335	-118.52213	POWER AND ENERGY PLANCHECK FOR A TI TO A RETAIL STORE. (ROSS). TOTAL  NEW CONNECTED LOAD IS GREATER THAN 400A, PERFORMANCE METHOD USED.SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 18620 SQ.FTB#19016-10000-27299	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31479	19041-30000-23822	11911 W SAN VICENTE BLVD #355	90049	11	129B145    78	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.05295	-118.47002	pc (t24 only) Tenant improvement to (E) office on 1604 SF of total floor area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31480	10041-20000-00959	8530 W VENICE BLVD	90034	10	123B173   500	5065007034	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.03424	-118.37908	12KW(DC) Photovoltaic system on commercial bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31481	15041-20000-28965	11400 W VENTURA BLVD	91604	2	162B173   617	2378021022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.13972	-118.37894	TI to existing commercial building (coffee shop). Plan check for energy only. Adding new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31482	17041-10000-35372	1053 S FEDORA ST 1-40	90006	1	129B197   452	5078016010	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			10/03/2017 12:00:00 AM			PC Info Complete	01/12/2018 12:00:00 AM	ADDRESS	34.05119	-118.2981	PC FOR NEW 40 UNITS APARTMENT BUILDING. SCOPE INCLUDES NEW SERVICE 120/240 1600ATOTAL AFFECTED AREA 26,161 SQ FTB# 16010-10000-05342	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31483	18041-20000-32659	14061 W VANOWEN ST	91405	2	183B153  1112	2216014003	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.19407	-118.43966	Change of use from retail to dental office.  Plan check for power and energy.Building application number: 18016-20000-16768.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31484	12041-10000-23791	735 S FIGUEROA ST SPACE-120	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	TENANT IMPROVEMENT TO EXISTING TAKE OUT RESTAURANT SPACE  AT EXSTING FOOD COURTPLAN CHK IS FOR TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31485	11041-10000-14915	19389 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	07/18/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.18744	-118.55559	"""COMPLY WITH DEPARTMENT ORDER effective date02/13/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""     NEW FIRE ALARM FOR RETAIL SPACE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31486	12041-20000-09555	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.30155	-118.46112	Install electrical equipment for Building 3.  New load exceed 400 amp.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31487	15041-10000-41641	978 S MARIPOSA AVE	90006	10	129B197   103	5078003016	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.10	Electrical	Electrical	Apartment			12/10/2015 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.05337	-118.29881	PLAN CHECK FOR ENERGY ONLY OUTDOOR/INDOOR. FOR NEW 3-STORY 7-UNIT  APARTMENT BUILDING.  TOTAL SQUARE FOOTAGE 8126.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31488	19041-10000-48861	1522 S ST ANDREWS PL	90019	10	126B193   139	5073009014	R2-1-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Closed	01/30/2024 12:00:00 AM	ADDRESS	34.04465	-118.31142	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31489	17041-10001-30183	19600 W PLUMMER ST Suite 600	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.2426	-118.5602	Supplemental for updating wattages for lights L2 and L3. All changes clouded under delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31490	15041-20001-10046	12460 W OSPREY LANE unit #1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	Expedite per applicant request(((((Plan check for PV roof mounted system for tri-plex unit #1 with system size: 1.84kW. PV clearance shall apply to unit #2 and #3 for address 12460 Osprey Lane, Los Angeles CA 90094))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31491	18041-10001-40295	7843 N LANKERSHIM BLVD	91605	6	189B169   517	2310025***	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	ADDRESS	34.21329	-118.38805	expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31492	15041-20000-19290	15705 W NORDHOFF ST	91343	12	198B141   667	2671012026	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.23574	-118.47462	Plan check for Title 24 only. Project site is an existing commercial building (gas station). Project scope is a tenant improvement to yard and canopy lighting. Total outdoor lighting area = 17,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31493	18041-20000-15782	6300 W WILSHIRE BLVD #1870	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	05/26/2018 12:00:00 AM	ADDRESS	34.06319	-118.36591	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31494	17041-20000-00349	1925 S LELAND ST	90731	15	012B193   989	7460027026	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2972.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM			PC Info Complete	01/20/2017 12:00:00 AM	ADDRESS	33.72653	-118.30135	PV1.  Install roof mounted grid tied 5 kW PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31495	15041-10000-16262	700 N FARING RD	90077	5	144b153   738	4358007018		West Los Angeles				2621.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM				NEW LUMINAIRES IN EXISTING CLASSROOM THAT HAS A VARIABLE PARTITION at the hazy academic center  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31496	16041-10004-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS. ADDITION OF SOME CIRCUITS AND UPDATED T24 AND LIGHTING. FLOOR PLANS HAVE BEEN UPDATED. PC FOR CHANGES NOTED DELTA DCN-027.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31497	12041-10000-19230	2011 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	PIN	34.06587468	-118.19737837	PLAN POWER AND ENERGY EXISTING COMMERCIAL BUILDING. NEW 2000A SERVICE AND EQUIPMENT (CORE & SHELL) POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31498	17041-10000-01294	8810 N DELCO AVE	91306	3	195B109   152	2781003015	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM			Corrections Issued	01/13/2017 12:00:00 AM	ADDRESS	34.23024	-118.57837	Installing new pv 1 system for single family dwelling on roof top. Central inverter is rated at 6.0 KW being fed by 22 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31499	17041-10000-19689	12121 W BLUFF CREEK DR #200	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	33.97874	-118.40463	TI SO SUITE 200. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31500	11041-10000-05305	17380 W SUNSET BLVD	90272	11	126B117   650	4415019012	C2-1VL, C2-1XL, P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.01	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM	03/17/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.03924	-118.55462	New fire alarm system in Vons Store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31501	14041-20000-04340	801 E 7TH ST	90021	14	126A213   287	5147028039	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Expired	04/11/2016 12:00:00 AM	ADDRESS	34.03955	-118.24481	"Lost Plans.  Resubmit for plan check.  Subdivide first floor into 13 retail spaces.  Plan check for power and energy.""COMPLY WITH DEPARTMENT ORDER effective date02/14/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31502	12041-10000-24705	1601 W JAMES M WOOD BLVD	90017	1	130-5A205 241	5142017010	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Info Complete	11/19/2012 12:00:00 AM	PIN	34.05112662	-118.27339536	New 800 Amp service & panel. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31503	14041-20007-29874	12860 W RIVERSIDE DR	91423	4	168B161   422	2357033021	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	PIN	34.15733931	-118.41348969	01-31-2019 Changes to an approved set of plan, Changes include remove disconnect at the motor, MCC has lockable disconnect in open position 430.102(B) Exception. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31504	17041-20001-13042	13027 W STRATHERN ST	91605	2	189B161  1196	2304015029	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.21599	-118.41713	expeditepv1install roof mounted pv system sized 8.9kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31505	18041-10000-27604	21120 W DEVONSHIRE ST	91311	12	204B105   344	2747005010	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Issued	07/24/2018 12:00:00 AM	ADDRESS	34.25707	-118.59372	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31506	14041-20000-02991	6767 W FOREST LAWN DR	90068	4	162B181   617	5581028005	C1-1D	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.14432	-118.33993	T24 ENERGY ONLY. EXISTING OFFICES. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31507	17041-10000-37189	6927 N SIMPSON AVE	91605	2	183B169   350	2321016026	RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.19659	-118.38907	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31508	14041-20001-31028	12039 N HAVANA AVE	91342	7	216B149   379	2611017004	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM			PC Approved	01/02/2015 12:00:00 AM	ADDRESS	34.28898	-118.45435	WXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 10.4 DC.(32) SUNPOWER 327 MODULES(1) SMA SB3000(1) SMA SB6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31509	18041-10000-02035	2025 S AVENUE OF THE STARS	90067	5	132B161   724		C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	09/28/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	Plan check for a new fire alarm system for a commercial building. Scope includes (965) devices, (28) power supply and (1) fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31510	13041-10000-22306	12127 N VISTA RANCH AVE	91342	7	216B145   288	2611038014	A2-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.29031	-118.46164	PV1.  INSTALL 4.25 KW AC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT INTO MAIN SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31511	15041-10000-43433	17383 W SUNSET BLVD A345	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.03917	-118.55529	PC for energy only to an existing commercial building (offices). Adding new lighting and power. Sqft = 940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31512	18041-10000-11967	1438 E 6TH ST	90021	14	126A217   148	5164014025	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.03814	-118.23125	PLAN CHECK FOR TITLE 24 ONLY FOR TI OF EXISTING WAREHOUSE AND NEW OFFICES. TOTAL AFFECTED AREA = 3903 SQ. FT.BUILDING PERMIT # 18016-10000-09400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31513	17041-10000-08952	380 WORLD WAY 3S3-05A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Title 24 only in existing space LAX new remote storage and office space. Total area:1,218 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31514	17041-30000-20763	5001 W WILSHIRE BLVD 208-209	90036	4	135B185   544	5507019029	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.06229	-118.33908	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a change of use/tenant improvement from retail to dental office. Total lighting area = 2,387 sq. ft. This facility will only be used as basic care facility   - no invasive(anesthetic) procedures shall be performed.Note: Building application has been generated under 17016-30000-11891	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31515	16041-20000-02874	8662 N LINDLEY AVE	91325	12	195B125   862	2787001021	(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM			Corrections Issued	01/26/2016 12:00:00 AM	PIN	34.2283261	-118.5269823	Plan check for energy only. T. I. TO (E) RESTAURANT - Domino's Pizza. New lighting (incl. emergency). Area of work = 462sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31516	17041-10000-21928	400 S WESTERN AVE #204	90020	10	135B193   439	5503014026	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM			PC Info Complete	06/30/2017 12:00:00 AM	ADDRESS	34.067	-118.30888	PC FOR T24 ENERGY ONLY FOR SHELL OUT OF TENANT SPACE 204. PROVIDING LIGHTING AND PLUGS FOR VANILLA SHELL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31517	19041-10000-05404	12041 W WICKS ST	91352	6	195B165   119	2631005051	RA-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.23303	-118.39535	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31518	16041-20002-07883	7922 N HASKELL AVE	91406	6	189B141   117	2206001009	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.21463	-118.47476	Revisions to approved set.  Change of service voltage class to reflect site conditions and additional transformer proposed to accommodate service ratings.  Change of THWN-2 to PV wire.  Change of roof layout.  Change of inverter model and rating.  (((Install a roof mounted solar array on a Commercial building. Interconnect with a 600A MSP.System size: 20kW. (64) 315W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31519	15041-20001-31590	6525 W SUNSET BLVD 2nd Floor	90028	13	147A187   106	5547017038	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	34.09815	-118.33187	12/07/15CHANGES TO AN APPROVE SET. SCOPE INCLUDES REDUCING THE AMOUNT OF LIGHTING FIXTURES ON FLOOR PLAN AND REPLACING RECESSED WITH PENDANT/LED LIGHTS. PERMIT FEES PAID UNDER PCIS# 15041-20000-31590(((PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 2ND FLOOR ONLY. HIGHRISE. 7086 SQFT. 2008 ENERGY CODE PER ELIE MAALOUF. SUBMITTAL PER APPLICANTS REQUESTBUILDING PERMIT UNDER 06016-10000-11178	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31520	12041-10000-22033	1355 S HILL ST	90015	9	124-5A207  89	5134025020	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Public Safety Only			09/17/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.03646	-118.26342	NEW FIRE WARNING SYSTEM FOR AN EXISTING R-2 BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31521	13041-20000-22472	2219 E 15TH ST	90021	14	120A217   162	5167011041	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	PIN	34.02225397	-118.23278559	New 1600 A service and equipment for an existing industrial area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31522	16041-20000-37871	10028 W BENARES PL	91352	2	189B181    21	2403020046	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	Yes	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.21881	-118.34885	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31523	12041-10000-24736	8454 W MELROSE PL	90069	5	141B173   511	5528017029	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM	11/02/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.0834	-118.37515	TI in a retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31524	12041-10000-05114	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			PC Approved	03/06/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	New landscape lighting.  Plan Check Only for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31525	16041-20001-00485	7320 N WOODLAKE AVE	91307	12	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.20263	-118.63189	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 84 kWac and consists of (3) inverters, (36) modules, and (1) load center. Project site is an existing medical building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31526	16041-10000-27039	12100 W WILSHIRE BLVD STE 1520-1530, 1550	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	TItle 24 plan check only.  Total area = 3,067 sq. ft.  T.I. to existing commercial highrise.  Seperating tenant space into three suites.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31527	19041-10000-38343	1632 N BELLEVUE AVE	90026	13	136-5A209  71	5404014900	OS-1XL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.07013	-118.26075	INSTALLING NEW LED POLE MOUNTED LIGHTING FOR A SKATE PARK. SCPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA 6757 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31528	12041-20000-28170	10014 N CLYBOURN AVE	91040	2	204B173   399	2542009030	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.25247	-118.36981	Enphase system on roof of single family dwelling with new pv subpanel and replacement of the main service circuit breaker with a new 175 ampere circuit breaker.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31529	19041-10000-17273	2410 N WEST SILVER LAKE DR	90039	4	150A207   294	5439024032	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.10435	-118.26642	Plan check for a 6.8kw DC / 6KW AC roofmounted system with 22-modules, (1) inverter interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31530	15041-10000-14577	1321 E PALMETTO ST	90013	14	126A217    38	5164003012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.04034	-118.23199	TI-24 TO AN (E) COMMERCIAL BUILDING. NEWLY CONNECTED LOAD LESS THAN 400 AMP, PC FOR ENERGY ONLY. TOTAL SQ. FT. 6817	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31531	18041-10000-04670	10250 W SANTA MONICA BLVD #1250	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			PC Info Complete	02/22/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for T24 only, TI for an (E) retail space in Westfield Century City.  New lightings and power using an Existing 100A tenant's panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31532	19041-20000-19448	757 N COLE AVE	90038	13	141B185   274	5533034001	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			05/22/2019 12:00:00 AM			PC Info Complete	12/31/2019 12:00:00 AM	ADDRESS	34.08509	-118.33004	800A 240/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.  Methane buffer zone project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31533	13041-10000-17030	600 S SPRING ST SUITE 1	90014	14	129A211   252	5144001020	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.04568	-118.25098	permit to be pulled at EPC counter only. PC for energly only . less than 400A per applicant. all emergency is existing except for 1 exit sign installed in the dining area. TI FROM COFFEE BAR TO PUB. see inspection fees from applicant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31534	11041-20000-13203	12115 W SAN VICENTE BLVD 1-51	90049	11	129B141   208	4404007***	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	34.05199	-118.47535	PLAN CHECK T24 PLAN CHECK FOR GENERAL LIGHTING IN CORRIDORS FLOOR 1 THRU 4 AND LOBBY. EMERGENCY LIGHTING EXISTING TO REMAIN. NO NEW CKTS.  (Locations of the EXIT signs will be verified by LA Fire Department).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31535	10041-10000-04334	333 S GRAND AVE 14th FL	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM			PC Info Complete	03/10/2010 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check T-24 Energy (general/emergency) lighting for a TI on 14th FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31536	12041-10000-10262	14255 W DELANO ST	91401	6	177B153   452	2240020026	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			05/04/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.18278	-118.44413	New fire alarm system for a new 6-unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31537	16041-20001-40989	1077 W 38TH ST	90037	8	117B197   508	5037015030	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Info Complete	12/13/2017 12:00:00 AM	ADDRESS	34.0174	-118.29395	12.13.2017 - Plan check for modifications to approved set. Add common area laundry circuits - update load schedules, demand load/voltage drop, and floor plans. Add electric range circuit in all dwelling units. Add IDF room circuits. Add elevator pit and machine room circuits. Revise courtyard lighting - update floor plan and T24 documents. Changes clouded delta blank (no number).======Plan check for power and energy. New 5 story building - 4-story 140 unit apartment (10 typ. units) over ground level parking garage and office space. (2) 2500A services and (1) 1000A service. T24 - indoor: 80,830sqft ; outdoor: 39,286sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31538	14041-20001-18152	3617 S ROSEWOOD AVE	90066	11	111B149   264	4245011015	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM			PC Approved	07/24/2014 12:00:00 AM	ADDRESS	34.00305	-118.4463	Fee is 0.00 base on Senate bill 1222 from 2012.Plan check only for relocating modules from roof-top.(((4.5KW AC PV1 roof-mounted systen with (21) Enphase M215 microinverters and Trina Solar TSM-250P modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31539	16041-20000-41490	617 W 7TH ST 11th Floor	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.04779	-118.2571	Common area corridor TI to (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31540	19041-20000-13547	7331 N HINDS AVE	91605	2	186B169   801	2317018042	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.20384	-118.39119	SERVICE UPGRADE FOR EXISTING COMMERCIAL FROM 200A TO 600A, INSTALLING 600A PANEL, AND (3) 200A SUB PANEL, AND (2) 100A SUB PANEL. SUB PANELS FOR FUTURE LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31541	17041-10000-41140	333 S GRAND AVE 41st FL	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31542	14041-20000-25868	2420 N BOWMONT DR	90210	4	153B165   141	4388012058	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.11667	-118.3973	PV1CENTRAL TRANSFORMERLESS INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31543	18041-10003-10626	2727 S KRIM DR	90064	5	126B165   597	4308015016	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.04119	-118.40004	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDITION OF ENERGY STORAGE SYSTEM, MODIFICATION OF SINGLE LINE DIAGRAM, AND RELOCATION OF LOADS. ALL CHANGES HAVE BEEN CLOUDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31544	18041-10001-12440	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM			PC Info Complete	08/30/2018 12:00:00 AM	ADDRESS	34.02557	-118.3665	"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 4 AND 8. CHANGES INCLUDE REVISING ELECTRICAL ROOM LAYOUTS, RELOCATING TRANSFORMERS, UPGRADING TRANFORMERS, UPSIZING DISTRIBUTION BOARD ""EQPBE"" FROM 400A TO 800A, UPSIZING DISTRIBUTION BOARD ""DBEA"" FROM 800A TO 1000A, ADDING ONE NEW MAKE UP AIR UNIT, AND REVISING PANEL SCHEDULES AND LOAD CALCULATIONS."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31545	16041-10000-29411	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	Full PC for core and shell alteration. Change of use from airplance hangar to office, 4-level building. Methane zone. All equipment on single line is new, shaded areas on single line to be done under a different scope. Installing (2) new main services medium voltage switchgears. MVSG1 is 3phase 3Wire 2000 Amps. MVG2 is 3phase, 3Wire 2000Amps. New lighting. Total sqft = 375,622 (Applicant assumption). ** Note Title 24 form have not yet been provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31546	18041-10000-38348	123 S FIGUEROA ST	90012	14	132A211     6	5151001026	C2-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.05725	-118.25278	PC FOR NEW  ( REPLACMENT) FIRE ALARM IN HIGH RISES ( 5 TOWERS) ON SINGLE PODIUM.SCOPE INCLUDES 31 PANELS AND 1213 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31547	18041-20000-15062	11301 N RIVERWOOD TER	91040	7	210B189    35	2551007004	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District, Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.27426	-118.31856	PV1.  Install 13 kW roof mounted grid tied PV system.  (40) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31548	14041-20000-20567	11351 N DRONFIELD AVE	91331	7	210B165     6	2532009009	A2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.27673	-118.4036	permit fee is $0.00 by state senate bill no. 1222New carport roof mounted PV system with system 68.75KW for new school.Note: The other PV system (57.25KW) is building roof mounted system is under 14041-20000-20563  Both PV systems are on the same plans.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31549	15041-10011-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	CHANGES TO THE APPROVED SET OF PLAN. PC FOR PLAN CHECK. CHANGES UNDER DELTA 42. SCOPE INCLUDES NEW PANEL, CIRCUITS AND REVISION TO T-24.TOTAL ADDED AREA 11134 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31550	11041-10000-03035	2000 S CENTRAL AVE	90011	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			02/16/2011 12:00:00 AM			PC Info Complete	02/25/2011 12:00:00 AM	ADDRESS	34.02249	-118.25156	NEW RESTAURANT.   CHANGED FROM RETAIL.   PLAN CHECK IS FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31551	18041-20000-37193	20216 W MOBILE ST	91306	3	180B113   446	2134020022	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.19023	-118.57311	Plan check for a PV1 roof-mounted PV system. System size is 14.7 kWdc/17.6 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31552	16041-20000-03871	1515 W 190TH ST SUITE 300	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	33.85852	-118.30531	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES FOR MAXIM HEALTHCARE SERVICES INC. 3RD FLOOR SUITE 300. SQFT 15630	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31553	16041-20000-26079	13661 W CHASE ST	91331	6	195B157   565	2640026002	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.23096	-118.42994	Plan check for PV roof mounted system. System size: 3.0kW with 12 modules and 1 inverter(3.0)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31554	12041-10000-14851	700 S FLOWER ST Garden Lvl	90017	9	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI in an exiosting LA Fitness on the garden level. Commercial High-rise. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31555	10041-10000-05508	12411 W SYLVAN ST	91606	2	177B165    32	2333007027	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	12/13/2010 12:00:00 AM	ADDRESS	34.18497	-118.40338	Plan check for a new 29.9 KW Photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31556	16041-20001-45041	6135 N VINELAND AVE	91606	2	177B173   584	2336036038	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	02/03/2017 12:00:00 AM	ADDRESS	34.18223	-118.37055	Revisions to approved set of plans.  Changes made to lighting plan, inclusion of outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31557	12041-20000-08558	8363 N RESEDA BLVD 8-9	91324	12	192B125   489	2785018004	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.02	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	08/01/2012 12:00:00 AM	ADDRESS	34.22256	-118.53629	TI for an existing medical office.   Install branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31558	10041-20000-08496	11631 W VICTORY BLVD	91606	2	180B169  1019	2335012019	C1-1VL, RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.01	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	06/30/2010 12:00:00 AM	ADDRESS	34.18685	-118.38564	Energy plan check office space. Existing ckts. Permit for replacing existing fixtures, relocate switches, relocate and add receptacles. Permit 2 of 3 (electrical/framing/plumbing)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31559	16041-10000-37864	6124 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.09782	-118.32339	PC for T24 for new lights and receptacles in Retail space with 920 sqft.**CONSTRUCT NEW TBAR CEILING TO EXISTING RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31560	12041-20002-05078	12629 W RIVERSIDE DR	91607	5	168B161   362	2357028021	(T)(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Apartment			10/24/2013 12:00:00 AM			PC Info Complete	11/26/2013 12:00:00 AM	ADDRESS	34.1578	-118.40799	"Supplemental application for changes to approved set of plans FOR ""DELTA  A"" clouded changes only. lighting changes, T24 forms, and reflected loads.    <<<<<217 units apartment building variance for fire alarm on file>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31561	12041-10001-12908	3525-3535 E WHITTIER BLVD 1--78	90023	14	121-5A227 188	5188005021	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Apartment			08/06/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	34.02645	-118.19754	Plan check for Delta 1 revision to approved plans. Changes to dwelling unit OCPD, residential distribution board feeders.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31562	11041-10000-17678	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	01/18/2012 12:00:00 AM	ADDRESS	34.10137	-118.34182	(2) 400A swithches supplied from (2) temporary generators to serve (1) each feeder for temporary stage power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31563	17041-10000-36002	326 W 58TH ST	90037	9	108B201  1296	5101040009	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Issued	03/19/2018 12:00:00 AM	ADDRESS	33.98958	-118.27935	Roof mounted PV system.System size 56KVA consisting of two inverters rated at 28KVA each, using 151 modules (Q.Peak G4.1-300),$0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31564	18041-30000-12873	3917 S TIVOLI AVE	90066	11	108B153   118	4236026009	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	33.99519	-118.44254	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (15) modules, (15) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31565	18041-20001-43392	10855 W PORTOFINO PL	90077	5	147B149   524	4369039024	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.09666	-118.45812	Expedited plan check fee. (((PV1.  Install 19.5 kW roof mounted grid tied PV system.  (60) modules with (2) 10 kW rated string inverters.  40.5 kWh energy storage system.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31566	11041-10000-25128	5231 W VERONICA ST	90008	8	117B177   505	5029024011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.01399	-118.36	PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31567	15041-20000-11271	10800 W ROSE AVE	90034	5	120B161   624	4254022035	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.02542	-118.41571	PV2. Apartment Building. Install roof mounted PV system sized 14 kW. Interconnected with main service panel. (66) Canadian Solar 255P Modules(2) SMA America SB 7000 Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31568	10041-10000-21401	8500 W BEVERLY BLVD 736B	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	12/15/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	remodel existing space to office and storage areasplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31569	19041-20002-13120	6040 W CENTER DR 1-218	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	33.97574	-118.39042	10/10/19CHANGES TO APPROVED SET DELTA 2 ONLY CHANGES TO LOAD SIDE CONNECTION. <<<Plan check for a PV2 roof-mounted PV system. System size is 71.18 kWdc/65.04 kWac-CEC and consists of (2) inverters, (195) modules, (1) transformer, and (2) load centers.Fees $0.00 due to California Senate Bill 1222 and AB 1414>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31570	15041-10000-19822	101 W 5TH ST	90013	14	129A211   281	5149022***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Closed	10/21/2016 12:00:00 AM	ADDRESS	34.0469	-118.24862	TI TO AN (E) BUILDING. CHANGE OF USE TO A RESTAURANT LOCATED ON THE GROUND LEVEL 400AMP SERVICE. FULL PC FOR ENERGY AND POWER. TOTAL SQ. FT. 1800.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31571	15041-10001-15677	11821 N MCLENNAN AVE	91344	12	216B133   635	2610002028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.28467	-118.50113	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 10.46 KW DC ROOF-MOUNTED SOLAR ARRAY  ON A SINGLE FAMILY HOME. (32) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTERS: POWER ONE PV1-3.8-OUTD-US AND 6000-OUTD-US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31572	13041-20000-30143	707 W WILSHIRE BLVD SUITE 3750	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.04893	-118.2572	T24 FOR EXISTING OFFICE SPACE. 1154 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31573	10041-20003-18676	818-838 E 29TH ST	90011	9	118-5A207 325	5128015052	(T)(Q)R3-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Info Complete	06/26/2012 12:00:00 AM	ADDRESS	34.01762	-118.26081	Changes from previously approved plans.  Changes include P.V. modules.Note: Previously approved submitted for reference only.*****Installation of two photovoltaic arrays of micro inverters, Enphase model 215, on the roofs of two carports.  the arrays supply existing distribution panels as shown on the plans.  System grounding and equipment grounding subject to inspectors's approval.  Existing permit 10041-10002-18676. *****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31574	12041-10000-07702	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	Existing Refinery, with new 200A  power distribution panel  with 24V power supply and circuits.  Class 1, Div 2, Group D area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31575	18041-10000-42279	11100 W SANTA MONICA BLVD 5TH FL	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM			Corrections Issued	11/05/2018 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI FOR CORRIDOR AND RESTR00M SPACE IN A COMMERCIAL OFFICE BUILDING, 5TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTICALS. TOTAL AFFECTED AREA  IS  1983 SQ. FT. T-24 ONLYB#: 18016-10000-35483	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31576	12041-10000-14722	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR T.I. FOR OFFICE #2200 OF HIGH-RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31577	14041-20002-29874	12860 W RIVERSIDE DR	91604	4	168B161   422	2357033021	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	PIN	34.15733931	-118.41348969	"10/01/2015 Changes to an approved set of plans. Load on Panel ""CW"" is no longer future and is now part of the scope of work for this project. Service loads calculations have been updated to reflect the updated Panel ""CW"" load.07/14/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 2. Changes include the relocation of Distribution Panel ""DP"".*****Previous Work Description*****Plan check for power only. Adding new car wash to existing gas station -> Upgrading service to 800A, installing new distribution equipment, and reconnecting existing equipment. Applicant had a precalculated check, verify/change/adjust fees on final."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31578	14041-20000-02126	11746 W HAMLIN ST	91606	2	180B169   890	2322017031	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.18857	-118.38942	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31579	13041-10000-10546	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	PHARMACEUTICAL MANUFACTURING. EXPANSION OF 800A BUS. TI OF 720 SQ FT.PLAN CHECK FOR POWER AND ENERGY FOR IMPROVEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31580	11041-20000-20784	350 S FIGUEROA ST # 550	90071	9	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	09/29/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.05438	-118.2549	T24 ENERGY/EMERGENCY TENANT IMPROVEMENT ON 5TH FLOOR OF EXISTING OFFICE BUILDING.   PERMIT FOR NEW CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31581	19041-30000-07920	633 W 5TH ST 72nd Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Info Complete	03/05/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project site is the 72nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,310 sq. ft.Note: Building application has been generated under 19016-40000-04957	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31582	19041-20001-03948	6161 W SANTA MONICA BLVD	90038	13	144B189   639	5534007020	C2-1D	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.09088	-118.32387	Title 24 plan check per inspector correction notice.  Emergency egress lighting existing to remain per applicant. (((Electrical for new editing rooms with plugs, switches, and light fixtures. Installation of new 100A sub panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31583	12041-20000-18042	6550 N VAN NUYS BLVD	91401	6	180B149   515	2237013906	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.18983	-118.44839	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31584	11041-20000-22268	5601 N DE SOTO AVE MOB 11	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	10/21/2011 12:00:00 AM		Permit Expired	11/13/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	addition to fire alarm	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31585	12041-20000-05078	12629 W RIVERSIDE DR	91607	5	168B161   362	2357028021	(T)(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Apartment			03/06/2012 12:00:00 AM	08/08/2012 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.1578	-118.40799	217 units apartment building variance for fire alarm on file	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31586	12041-10000-02573	10133 N SAN FERNANDO ROAD Building A	91331	6	204B161   502	2623032027	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.25424	-118.40986	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE TO RETAIL (FUTURE 7-ELEVEN). SCOPE OF WORK ARE RESTROOMS, BUILDING A EXTERIOR LIGHTING, AND HVAC UNITS ON ROOF. ALL OTHER FOR FUTURE TI. BUILDING POWER SUPPLY FROM BUILDING B UNDER #11041-20000-15246.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31587	15041-10000-33613	7615 N SAN FERNANDO ROAD	91505	2	186B177   561	2466036***	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.20898	-118.35615	PC FOR ENERGY. REMOVING EXISTING LIGHT FIXTURES AND REPLACE IT WITH NEW LED LIGHT FIXTURES. TOTAL AREA 14630 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31588	13041-10000-36219	416 N FAIRFAX AVE	90036	5	141B177  1410	5527030019	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.07873	-118.36128	TI IN RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31589	18041-30000-15431	2029 S CENTURY PARK EAST 25th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site are the corridors on the 25th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 3,110 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31590	14041-10000-21029	5857 N SYLMAR AVE	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.17731	-118.44671	PV1, INSTALL 5.00 KW DC ROOF-MOUNTED MICRO INVERTER SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCOMNNECT WITH MAIN SERVICE PANEL.(20) ENPHASE M215-60-211-S22-S23-S24,, 20 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31591	13041-20000-20336	7054 N TUNNEY AVE	91335	3	183B117   306	2130023007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Expired	08/25/2015 12:00:00 AM	ADDRESS	34.19899	-118.55687	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 5KW USING 25 MODULES. CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. MAIN SERVICE AND PANEL PERMIT HAS BEEN ISSUED UNDER APPLICATION # 13041-20000-20306.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31592	15041-10000-33568	1150 S OLIVE ST STE 2350	90015	14	126A207   101	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Info Complete	10/08/2015 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2212  IN SUITE 2350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31593	15041-10000-41797	4800 W WILSHIRE BLVD	90010	4	132B185    22	5507030001	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Info Complete	07/22/2016 12:00:00 AM	ADDRESS	34.06182	-118.33508	FULL PC, TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING; CHANGE OF USE FROM COMMERCIAL OFFICE TO CULTURAL CENTER. NEW 800 A SERVICE. SQ FT = 10,220. additional time has been added to check reconnection of existing equipment. misc permit to be issued. elevator and pump units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31594	17041-20000-06119	8369 W BEVERLY BLVD	90048	5	138B173   408	5514010027	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.07622	-118.3724	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR UNCLE PAULIE'S RESTAURANT. 982 +534 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31595	16041-20000-32178	1411 W 190TH ST 5th floor	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	33.85852	-118.30317	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR OFFICES.  5TH FLOOR  19,200 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31596	19041-30001-14870	11753 W IOWA AVE	90025	11	126B149  1332	4262013075		West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Apartment			11/12/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	09/12/2023 12:00:00 AM	ADDRESS	34.0409	-118.45527	PC FOR CHANGES TO APPROVED SET, CHANGE IS ADDITION OF A SEWAGE PUMP WHICH IS CLOUDED UNDER DELTA 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31597	12041-10005-30779	"12746 W JEFFERSON BLVD ""4"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	33.97756	-118.41709	Changes to an approved set of plans, changes consist of revisions to ligthing fixtures, and revisions to the energy calculations. Changes noted delta C. This application is PC only. (((Plan check power and energy for Building 4. Five story parking garage building with common subterranean parking to Building 1, 2, 3, and 4. Service supply from Building 3. Site located in methane zone. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31598	18041-30000-22140	1947 S SAWTELLE BLVD	90025	11	126B153  1455	4261030053	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Apartment			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.04122	-118.44415	Plan check for a fire alarm system in a (4) story (72) unit apartment with (1) fire alarm panel, (4) power supplies, and (215) fire alarm devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31599	14041-20000-33232	400 S WESTGATE AVE	90049	11	132B145   347	4401005035	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.05579	-118.47142	Based on the senate bill 2222 the permit fee is zero.PV1 SFD. TOTAL SYSTEM SIZE 13KWDC /16KW AC USING 2 CENTRAL TRANSFORMED INVERTERS RATED 8KW EACH. LEAVING ROOM FOR FUTURE SOLAR ADDITION.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31600	18041-10000-16746	14006 W RIVERSIDE DR STE 219	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Issued	06/07/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	Energy plan check for an existing retail space, Scope includes new lighting and equipment. Total area is 754-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31601	11041-20000-16036	8900 N DE SOTO AVE #B 102	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.23162	-118.58832	PLAN CHECK T24 ENERGY/EMERGENCY OFFICE SPACE TENANT IMPROVEMENT BUILDING #102. PERMIT FOR ELECTRICAL WORK ON EXISTING CKT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31602	16041-20000-39218	16357 W PLUMMER ST	91343	12	198B137    32	2677020013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.24309	-118.48919	Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with 200A MSP, derating main to 175A. Existing 6kW ungrounded system on roof. New system is 4.2kW ungrounded w/(16) 315W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31603	18041-10000-31339	879 W 190TH ST 10TH FLOOR	90248	15	060B197   499	6121021012	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	33.85951	-118.28963	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR OFFICES. HIGH RISE. 10TH FLOOR.BUILDING PERMIT # 18016-10000-26364	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31604	15041-20000-27922	1888 S CENTURY PARK EAST PRK STRT	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.06104	-118.41402	Remodel valet parking counter on level P1; And remodel elevator lobby for levels P1- P3, P5-P8. pc for energy only. new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31605	18041-20000-12832	625 S BARRINGTON AVE	90049	11	132B145   263	4401012012	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.05687	-118.46824	PC for new FA system for five level apartment with subtarrenean parking. Installing new FACP panel, one annunciator and 197 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31606	12041-10001-07487	10141 N LARWIN AVE PV 1	91311	12	204B101   228	2724003***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			06/21/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.25471	-118.61641	PLAN CHECK ONLY. NEW ROOF MOUNTED 5.28KW PHOTOVOLTAIC SYSTEM FOR CONDO (SINGLE FAMILY). EXISTING PERMIT #12041-10000-07487	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31607	13041-10000-35598	11985 W BLUFF CREEK DR BLDG #3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  35,665 SF WITH NEW SURFACE PARKING LOT. 3 TOTAL BUILDINGS.  THIS IS BUILDING 3/5 IN THE SAME PARCEL. TITLE 24 ENERGY FEE CHARGED UNDER THIS BUILDING. METHANE ZONE. BDLG PERMIT: 13110-10000-04243	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31608	15041-20001-41543	23745 S PRESIDENT AVE	90710	15	042B193   542	7439004010	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	33.81018	-118.30419	PV system. Install a roof mounted solar array on a SFD. Interconnect with a 100A MSP.System size: 3.8kW. Ungrounded system. Using 300W power optimizers (one per module).(10) 255/235W pv modules on one string.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31609	14041-20000-02150	4934 N LOUISE AVE	91316	5	168B133   119	2289008015	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.15952	-118.50964	Roof mounted PV system with Optimizer and transformerless inverters, system size 9.75KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31610	18041-10000-33111	3668 W BEVERLY BLVD	90004	13	138B197   328	5501009005	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.07618	-118.28851	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31611	15041-20000-31972	809 S BUNDY DR 1-50	90049	11	129B141   411	4264010***	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			09/28/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.05	-118.47214	Title 24 plan check only.  Total area = 6,884 sq. ft.Installation of new lighting in hallway areas of three story low rise apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31612	10041-20000-12283	7325 N MEDICAL CENTER DR suite 203	91307	12	186B097   830	2021014040	(Q)CR-1VL, CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM			PC Approved	06/28/2010 12:00:00 AM	ADDRESS	34.20328	-118.62963	delta 2 revisions to 10041-20000-06175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31613	19041-10000-15557	1629 W 223RD ST	90501	15	048B193   658	7346019025	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	33.82463	-118.30744	(ePlan)  New 4.29W DC, 3600W AC rooftop PV solar system of (13) modules with (1) 3.6 kW AC inverter to be installed.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31614	13041-10000-07435	8729 N COSTELLO AVE	91402	7	195B153   868	2638011009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.2292	-118.44127	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. CENTRAL INVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 7KW. USING 36 MODULES. PV1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31615	16041-10001-35218	606 N ARDMORE AVE	90004	13	141B193   871	5520002021	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Apartment			10/05/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.08187	-118.30153	Expediate per applicant request(((((Plan check for PV roof mounted system on multiple untis building. Service size: 400A splite bus(Exising).  System size: 3.0kW with 12 modules and 1 inverter(3.0kW)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31616	15041-10000-30906	9317 W PICO BLVD bldg B	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05542	-118.3934	PC FOR T24 ONLY. BUILDING B. TOTAL ADDING LOAD LESS THAN 400A. YOUNG ISRAEAL OF CENTURY CITY. TOTAL AREA 3942 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31617	17041-10000-34487	1825 S VERMONT AVE	90006	1	126B197   588	5075017020	(Q)CM-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			Reviewed by Supervisor	10/03/2017 12:00:00 AM	ADDRESS	34.04086	-118.29181	PC FOR POWER AND ENERGY FOR DENTAL CLINIC TI.B#17016-10000-27286	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31618	12041-20000-15350	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to a high rise building on the 41st 42nd floor. 41st floor - rooms 4101 & 4102, 42nd floor - rooms 4228B, C, 4226, 4225A, 4225 as shown on the plans.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31619	14041-10000-33835	12301 W BRANFORD ST	91331	7	201B165    30	2537015017	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	PIN	34.25073021	-118.40161042	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31620	16041-10000-06498	2700 W COLORADO BLVD #146	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.14248	-118.22438	T-24, TI TO A BAKERY WITHIN A SUPER MARKET. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. F.T 1302	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31621	15041-20000-34579	6250 N TOPANGA CANYON BLVD Ste.1380	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Issued	01/12/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	PLANCHECK FOR POWER AND  ENERGY.  TI IN RETAIL MALL . NEW TOTAL WINE AND MORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31622	18041-10000-08552	2054 N ROSCOMARE ROAD	90077	5	150B145   144	4377026015	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.10751	-118.46342	PC for 1.84kW(AC) rooftop PV system. Installing 8 new modules with enphase microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31623	14041-10003-13075	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM			PC Approved	02/10/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	02/08/16Changes to an approved set of plans. All changes are made under delta 5. Scope includes adding a cut-sheet from illsco manufacturer, changing feeder tie-in using muti-tap connectors, and changing the inverter layout in the electrical room. Note: permit paid under PCIS#14041-10002-13075(((Revisions to permitted plans for new 5-stories parking structure under construction.New circcuits, panelboards, and some feeders changed from CU to AL. (((((Full Plan check for new 5 stories parking structure,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31624	10041-20000-05358	19950 W RINALDI ST	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM	06/21/2010 12:00:00 AM		Permit Finaled	08/27/2010 12:00:00 AM	ADDRESS	34.27535	-118.56939	Dental office TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31625	12041-10000-18261	8601 S LINCOLN BLVD STE 190	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	33.95939	-118.41943	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING ONLY TENANT IMPROVEMENT FOR A FUTURE TENANT IN SUITE #190 (SHELL ONLY). FIRST TIME TENANT SHALL REQUIRE COMPLETE PLAN CHECK.  Permit Fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31626	14041-20000-06214	2807 S BAGLEY AVE	90034	5	126B165  1100	4309021017	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.03739	-118.39312	pv1 single family dwelling. total system szi e5.37kw ac using microinverter enphase m215. using standard plan. 25 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31627	17041-20000-18834	333 S GRAND AVE 3rd Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for power and energy. Full floor TI/Change of use on 3rd floor from office to commercial kitchen in existing high rise building. 21,390sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31628	19041-10000-26825	21050 W KITTRIDGE ST	91303	3	180B109   377	2148029022	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Apartment			07/17/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Closed	03/22/2021 12:00:00 AM	ADDRESS	34.19099	-118.5916	Temp power plan check for a New 7-story, 395-unit, Apartment building. Scope includes (1) 600-Amp 277/480v service, (42) panels, and (126) ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31629	10041-10000-00279	100 S LA CIENEGA BLVD C-122	90048	5	138B173   620	5511013069	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM	06/10/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	ADDRESS	34.07403	-118.37626	Tenant modification to space C-122 which is the first time tenant in the space.  A previous permit for the tenant space  was submitted on application  09041-10000-24426 which is yet to be assigned.  This permit can not be issued until the 09041-10000-24426 permit is finaled.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31630	14041-20000-14159	11600 W WILSHIRE BLVD Unit 199	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	02/14/2015 12:00:00 AM	ADDRESS	34.05034	-118.45947	Renovation of existing commercial tenant space for coffee shop.  Title 24 plan check for changes to lighting system.  Newly connected load under 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31631	15041-10000-05050	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	Titl2 24 plan check only.  Total area = 614 sq. ft.T.I. to existing restroom area including new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31632	13041-20000-32268	12710 N AZORES AVE PV1	91342	7	219B161    30	2525024023	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.30108	-118.41314	New 9.3kw rooftop PV system for an existing single family dwelling.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31633	18041-20003-10667	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM			PC Approved	06/28/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	"06-28-2019 Changes to an approved set of plan, changes include relocate load from Panel ""LP1"" to ""1LA"". No new load is being added, relocated load only, Service load calculation shall remain same.  All Changes has been clouded as delta 7 only. Plan check only.Note: panel ""LP1"" and ""EV""was removed in the previous supplemental plan check."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31634	17041-20000-43030	814 S HOBART BLVD	90005	10	132B193   674	5093017003	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	02/02/2021 12:00:00 AM	ADDRESS	34.05723	-118.30517	Plan check for power only. Project site is an existing 4-story apartment building. Project scope is a service upgrade to 1,000-amp, the addition of unit panels, and additional circuits in the kitchen and living rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31635	17041-20000-02668	13987 W REX ST	91342	7	228B153   267	2503022032	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.3222	-118.43855	PV1.  Install 5.0 kW AC roof mounted grid tied PV system.  (21) modules with (1) 5kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31636	11041-10000-11687	122 N LARCHMONT BLVD	90004	4	138B189   882	5515024003	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM			PC Approved	06/07/2011 12:00:00 AM	ADDRESS	34.07368	-118.32343	CHANGE OF USE FROM RETAIL TO TAKE-OUT BAKERIES. NO SITING ON PREMISES.PLAN CHK IS FOR TITLE 24  PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31637	15041-20001-06580	1018 S WESTWOOD BLVD	90024	5	132B153    28	4363020007	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.06199	-118.44516	Lost original approved set of plans per applicant.  Verification of plan check details on photocopy of approved set.  Approved restamp made under '15041-20000-06580'(((Plan check for power and energy for T.I of the building with 800A service. Complete renovation for 3 floorss commercial buildingCOMMERCIAL T.I. TO INCLUDE SEISMIC STRUCTURAL RETROFIT OF ENTIRE STRUCURE (URM BLDG) NEW STOREFRONT.  ELEVATOR.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31638	14041-20000-25425	23933 W KITTRIDGE ST	91307	12	180B089   324	2034012024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.19121	-118.64801	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(23) SolarEdge P300 power optimizers(23) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31639	12041-10000-22627	5800 S VERMONT AVE TMP 1	90037	9	108B197  1417	5001015024	[Q]C2-1VL, [Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	PIN	33.98945019	-118.29090886	TI IN AN EXISTING RESTAURANT. EPC IS FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31640	19041-10001-02018	1925 S CENTURY PARK EAST STE 1300-&1380	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	pc revision to an aprroved set. changes marked delta 1 . removal of a transformer	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31641	17041-10000-05143	970 W 190TH ST # 270	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	33.85812	-118.29302	PC for T24 energy only for office TI with 5583 sqft. Office space are in a high rise building.%%TI OF OFFICE SPACE # 270 : NEW NON BEARING PARTITION WALLS ; NEW CEILING PANELS ; MILLWORK ; FINISHES . ( 5400 SF ) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31642	14041-20000-32410	11200 N CORBIN AVE	91326	12	210B117   384	2701040027	(Q)C1.5-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.27517	-118.5618	PC FOR T24 ENERGY ONLY. NEW LIGHITNG AND RELOCATED PARTITIONS. WORK DONE IN NON MEDICAL AREAS OF DR OFFICE. NO 517. T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31643	13041-10000-25043	707 W WILSHIRE BLVD 19TH FLOOR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.04893	-118.2572	TITLE-24 ,TENANT IMPROVEMENT IN A HIGH-RISE BUILDING. EMERGENCY LIGHTING ON EMERGENCY CKTS FED VIA EXISTING GENERATOR. TOTAL SF = 15000 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31644	19041-20000-43175	1330 W PACIFIC COAST HWY	90710	15	033B197    21	7411007021	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Issued	01/09/2020 12:00:00 AM	ADDRESS	33.78921	-118.30005	New subpanels, power, and lighting for (E) building.  Plan check for energy.  Comply w/dept. order with an effective date 2-6-19.  Permit to expire 30-days from issuance date	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31645	10041-20000-11765	16000 W VENTURA BLVD 102	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM			PC Approved	06/21/2010 12:00:00 AM	ADDRESS	34.15584	-118.48164	T.I.ENERGY, EMERGENCYFIRE LIFE SAFETY IS BY OTHERS 10041-10000-10017exist. permit 10041-90000-09623	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31646	11041-20000-26185	12050 W VENTURA BLVD	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.14349	-118.39426	TENANT IMPROVEMENT AT EXISTING RESTAURANT (3026SF) .***separate permit is being obtained for outdoor dining	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31647	17041-10000-43643	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	PC for methane detection system in two story building. Installing new gas detection panel, sensors, and three horn strobes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31648	15041-10000-02047	2121 S AVENUE OF THE STARS 9th Floor	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.05554	-118.41342	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31649	14041-10000-31661	13118 W RANGOON ST	91331	6	195B161   245	2627018022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.23374	-118.4184	PV1.  Installation of 6.867 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31650	19041-10000-25568	8500 W BEVERLY BLVD 153	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR T24 ONLY FOR A CHANGE OF USE FROM A RESTAURANT TO A NAIL SALON. SCOPE OF WORK INCLUDES NEW LIGHTING AND CONTROLS BOTH INDOOR AND OUTDOOR. TOTAL AFFECTED AREA IS 921 SQFT.B#: 19016-10000-20072	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31651	19041-10000-03647	4640 W HOLLYWOOD BLVD	90027	13	147B197   457	5542014007	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.10006	-118.29052	Install new FA system, (1) FACP, (1) Voice Evac panel, (29) devices on (E) synagouge with day school.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31652	15041-20000-27376	10835 N BARTEE AVE	91345	7	207B149   194	2615027024	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.26667	-118.4492	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31653	12041-10002-13171	16952 W BLANCHE PL	91344	12	219B133   513	2609026025	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.2955	-118.50128	Revision to approved plans. Changes to add additional inverter amd load center.            <<<New 11.04kw rooftop mounted PV system for an existing single family residence.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31654	17041-10000-11632	7223 S VERMONT AVE	90044	8	102B197  1251	6019021012	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.97408	-118.29198	PC for power and energy for new 400A service in an Auto Shop.Check for hazardous location. Total area is 3200 sqft. Building #16041-20000-02043	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31655	13041-10000-33415	777 S FIGUEROA ST # 4650	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.04828	-118.26116	TENANT IMPROVEMENT IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA ENERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31656	11041-10000-27329	12930 N WINTHROP AVE	91344	12	222B133   232	2602016023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2011 12:00:00 AM	12/23/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.30546	-118.50743	Plan check 8.97KW Roof mounted photovoltaic system single family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31657	16041-30000-33755	2049 S CENTURY PARK EAST 30th Fl-Corridor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Issued	09/27/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing high-rise corridor 30th floor based on 2008 Title 24 code modification in place. Total area: 1,415  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31658	16041-30000-28592	2049 S CENTURY PARK EAST 30th Floor-Lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Issued	08/11/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check Title 24 only in existing high-rise elevator lobby 30th Floor. Total area: 330 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31659	17041-20000-12849	9036 N RESEDA BLVD	91324	12	198B125   273	2769001024	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.23507	-118.53587	TI to (E) teller space and break room in commercial bank.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31660	10041-20000-20798	11541 N BLUCHER ST bldg7	91344	12	213B145    79	2605002012	QC1-1VL, QP-1VL	North Valley	Granada Hills - Knollwood		YES	1092.00	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	PIN	34.27943684	-118.47043731	Permit expired (BLDG. 7).  EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31661	13041-10000-16679	5020 W WILSHIRE BLVD	90036	4	132B185    14	5507028029	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			PC Approved	05/13/2013 12:00:00 AM	ADDRESS	34.06191	-118.33886	RENOVATION OF EXISTING STARBUCKS.  NEW LIGHTING PLAN AND SOME NEW EQUIPMENT.  PC FOR ENERGY ONLY. T24, with Emergency lighting.  Load is less than 400 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31662	14041-20001-30023	2514 N COMMONWEALTH AVE	90027	4	154-5A201 164	5592018012	RE11-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2014 12:00:00 AM			PC Approved	11/19/2014 12:00:00 AM	ADDRESS	34.11631	-118.28574	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.04 DC.(31) CANADIAN SOLAR CS6P-250P(14) CANADIAN CS6P-235PX(1) SOLAREDGE SE10000US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31663	17041-30000-23241	6569 S VERMONT AVE	90044	8	102B197   168	6014012032	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.97934	-118.29198	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from office to restaurant on the 1st floor and a tenant improvement to the 2nd floor. Work includes a new service, new distribution system, and new lighting. Total lighting area = 10,090 sq. ft.Note: Building application has been generated under 17016-30000-18469	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31664	17041-10000-27490	12121 W WILSHIRE BLVD ste 100	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.04386	-118.46816	TI FOR MEDICAL OFFICE. PHYSICAL REHAB. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31665	17041-10000-20732	6600 N TOPANGA CANYON BLVD 2096 C	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	CHANGE OF USE FROM (E) RETAIL TO TAKE OUT RESTAURANT FOR A NEW PRETZEL SHOP  598 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31666	17041-10000-39126	16749 W BOLLINGER DR	90272	11	129B121   938	4415008006	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Expired	06/02/2024 12:00:00 AM	ADDRESS	34.04608	-118.54474	Install New PV1 rooftop solar system on a SFD. 5kW AC/ 5.2 kW DC, (16) modules, (1) inverter, and (1) ESS Tesla Powerwall 13.5 kWh , and 1 load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31667	19041-20000-15218	421 N HELIOTROPE DR ev2	90004	13	141B197  1173	5520016022	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Apartment			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Issued	04/25/2019 12:00:00 AM	ADDRESS	34.07839	-118.29606	addition of 13 EV chargers on EMS to an existing 200 amp service.  plan check for power	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31668	18041-10000-34954	624 N EVERGREEN AVE	90033	14	129A227   349	5178011029	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2038.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Info Complete	09/21/2018 12:00:00 AM	ADDRESS	34.04623	-118.19854	Install new rooftop solar system on one of 4 units apartment building. System size is 10.08 kW AC, scope inlcudes (42) CS6K-295MS modules, (42) Enphase IQ7-60-2-US, (1) Enphase combiner box	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31669	19041-30000-08731	106 S KINGS ROAD	90048	5	138B173   645	5511016002	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	10/07/2020 12:00:00 AM	ADDRESS	34.0742	-118.37198	Plan check for a fire alarm system for a 4-story, 9-unit apartment building. System consists of (1) FACP, (1) annunciator, and (53) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31670	17041-10001-21121	6338 N LAUREL CANYON BLVD	91606	2	180B165   785	2334003029	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM			PC Approved	09/11/2017 12:00:00 AM	ADDRESS	34.18599	-118.39631	PC FOR T-24, SCOPE OF WORK INCLUDES NEW LED LIGHTING AND 2 NEW RECEPTACLES. EXISTING SERVICE,  EXISTING PANELS AND EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31671	19041-20000-35784	16030 W SHERMAN WAY	91406	6	183B141   129	2224004006	C2-1VL, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Apartment			09/10/2019 12:00:00 AM	07/16/2020 12:00:00 AM		Permit Finaled	02/24/2022 12:00:00 AM	ADDRESS	34.20091	-118.48248	Plan check for power and energy for new service 1200A 120/208 Volts. Scope of work includes panels, equipments, and lights.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31672	11041-10000-20814	600 W WORLD WAY Terminal 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	05/15/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	New conveyor motors for LAX Terminal 6.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31673	11041-10001-27511	333 S HOPE ST 23rd fl	90007	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	PIN	34.05338925	-118.25347338	Revision to the approved plan. Change the lighting in office area and addition of 2 luminaires. Plan check is for Title 24 for delta 2 changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31674	13041-10000-19351	5707-5709 N CAHUENGA BLVD	91601	2	174B177   301	2415024013	CR-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.17429	-118.36174	CHANGE OF USE FROM OFFICE/WHSE TO OFFICEplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31675	14041-10000-04445	6141 N KESTER AVE	91411	6	178-5A149 317	2242024048	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.18203	-118.45769	T24 only.Removing HID light fixtures and replacing with new fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31676	17041-10000-10194	285 W WHALERS WALK BER 28,29,-30,31	90731	15	006B201     3	7440041906	A1-1, M2, R1, R4, [Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	33.71788	-118.28152	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 198750 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31677	18041-10000-26940	945 W PACIFIC COAST HWY	90744	15	036B201   757	7414035034	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	33.79071	-118.27453	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31678	18041-20002-08482	15000 W CORONA DEL MAR	90272	11	123B129   711	4411030007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	34.03145	-118.52276	Revisions to approved plans.  Wiring and overcurrent protection detail changes. *original*Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (3) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31679	10041-20000-02313	8235 W FOOTHILL BLVD	91040	7	204B193    44	2555022006	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM			PC Approved	02/10/2010 12:00:00 AM	ADDRESS	34.25987	-118.31258	new tenant panel exist.permir 09041-20000-23302	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31680	18041-10000-29160	7011 N SHOUP AVE	91307	12	183B101   868	2024025026	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.19759	-118.61495	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31681	17041-20000-10129	11555 W CANTARA ST	91605	6	192B169   514	2311001012	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	08/11/2020 12:00:00 AM	ADDRESS	34.21938	-118.38398	New exhaust hood system for (3) commercial gas ovens.  Plan check for power per applicant request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31682	14041-20000-05189	12695 W SANDHILL LANE UNIT 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97727	-118.41529	Roof mounted PV system with 3KW AC USING TRANFORMERLESS INVERTER. THIS IS PART OF A SERIES SET OF SUBMITTALS. THIS PV SYSTEM TO INTERCONNECT TO COMMON SERVICE. THIS IS PROJECT 2 OF 3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31683	19041-10000-34194	28118 S WESTERN AVE	90732	15	024B193   622	7442030207	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	09/29/2020 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	33.76393	-118.31021	Full Plan check for power and energy. Scope of work  includes new (2) 200A, 120/208V, 3PH, 4W feeders from a 1000A switch board and installation of outdoor lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31684	13041-10000-34514	9145 N RUBIO AVE	91343	12	198B137   838	2687025003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Closed	12/22/2014 12:00:00 AM	ADDRESS	34.23702	-118.49559	PV1, Install a 4.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (17) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31685	10041-20000-16539	225 S 26TH ST #25	90049	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	PIN	34.04786183	-118.49061927	Plan check for T-24 energy (general/emergency) lighting for restaurant/market TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31686	13041-10000-11574	5849 S CENTRAL AVE	90001	9	108B209  1461	6007003903	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	33.98854	-118.25818	NEW ELECTRICAL SYSTEM ON A NEW BUILDING. MARKET, 1-STORY. PLAN CHECK FOR POWER AND ENERGY. FIRE ALARM UNDER SEPARATE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31687	14041-10000-03081	4917 N FORMAN AVE	91601	4	168B177   265	2420015007	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.15966	-118.35305	PV1, Install 5.75 KW DC roof-mounted solar array on a 1-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(23) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31688	16041-10000-07885	1739 N ALBION ST	90031	1	136-5A219  59	5447027***	GW(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.06833	-118.22338	T-24, USE OF LAND FOR NEW PARK EXTENSION WITH TWO PARKING AREAS, NEW PLAYGROUND AND SOCCER FIELDS. SCOPE OF WORK INCLUDES NEW LIGHTING TO THE PATHWAY. TOTAL SQ. FT. 76,875.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31689	17041-10000-07691	833 N LA CIENEGA BLVD	90069	5	141B173    95	4337002076	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.08629	-118.37665	PC FOR T24 ENERGY ONLY. NEW LIGHTING AND SOME RECEPTACLES FOR OFFICE SPACE. TOTAL AFFECTED AREA IS 1780 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31690	14041-10000-33859	57 E MARKET ST	90291	11	108A143   429	4226007009	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Expired	02/06/2017 12:00:00 AM	ADDRESS	33.98811	-118.47335	PV2.  Install 8.5 kW DC roof-mounted, utility-interactive PV system.  355 sq. ft. array.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31691	17041-20000-36042	6301 W ARROWHEAD PL	90068	4	156B185    52	5577036047	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.12585	-118.32797	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31692	11041-10000-20757	13171 W MINDANAO WAY	90292	11	105B153    95	4212004005	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM			PC Approved	09/28/2011 12:00:00 AM	ADDRESS	33.98487	-118.43775	INTERIOR TI  AT A CVS PHARMACY STOREPLAN CHK IS FOR TITLE 24 FOR INSTALLATION OF A LUMINAIRE IN A HALLWAY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31693	15041-10000-15029	21355 W SHERMAN WAY Space-7246	91303	3	186B105   631	2111029001	(T)(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	34.20118	-118.5973	Energy plan check for an retail office T.I  with new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31694	18041-20002-07346	4108 N KRAFT AVE	91604	2	162B169   204	2368020023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.14276	-118.37992	pv1install roof mounted pv system sized 13.6kw interconnected with msp.  (3) tesla power walls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31695	17041-10001-01244	7080 W HOLLYWOOD BLVD #600	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM			PC Approved	02/24/2017 12:00:00 AM	ADDRESS	34.10134	-118.34445	02/24/2017 Changes to an approved set of plan. clarify scope of work, remove scope of work,  the scope of work has been clouded .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31696	15041-10000-03973	1656 S ARDMORE AVE	90006	10	126B193   297	5074025015	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.04345	-118.30263	PV1, INSTALL2.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERECONNECT WITH MAIN SERVICE PANEL.(9) MODULES: YINGLI #YL250P-29B(1) INVERTER: ABB # PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31697	17041-20000-23662	5537 W LA MIRADA AVE	90038	13	144B193   222	5536003018	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.09388	-118.31051	INSTALLATION OF NEW FIRE ALARM SYSTEM. 1 FACP AND 52 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31698	19041-20000-11120	23100 W AVENUE SAN LUIS	91364	3	171B097   954	2074020035	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	10/31/2020 12:00:00 AM	ADDRESS	34.16191	-118.62958	PV2.  Install 141.99 kW DC / 129.74 kW AC roof mounted grid tied PV system.  (389) modules with (4) 33.3 kW rated inverters.  Supply side connection.  $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31699	16041-10000-33892	13075 W VICTORY BLVD #102	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.18684	-118.41708	Plan check Title 24 only in existing space in shell building chipotle. Total area: 2,100 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31700	16041-20000-04069	9301 N TAMPA AVE #93	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 T.I. in existing space. Total area: 1,766 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31701	19041-10000-10259	1900 S MAIN ST	90007	9	123A207   167	5127025026	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.0308	-118.2646	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31702	14041-10001-22597	1200 N LA COLLINA DR	90069	4	144B165   183	4392016027	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.09238	-118.3956	PLAN CHK FOR FIELD CHANGES- REPLACE 3 EA 10KW STEAM GENERATORS WITH 2EA PHASE INVERTER/3PH STEM GENERATORS; ADDED RECEPTACLES. ALL CHANGES ARE CLOUDED (((((((((Renovation of (E) 17,023 square feet single family dwelling.  Rewiring of house and new 1200A  service and service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31703	13041-20000-03827	7501 W ALPINE WAY	91042	7	213B197    83	2552043021	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.27746	-118.2954	Photovoltaic system on roof of a single family dwelling using DC strings and one inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31704	17041-20002-09891	12601 W PIERCE ST 41, 42, 53	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	12-19-2018 Changes to an approved set of plan, changes include addtion of performance meter. all changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31705	12041-10000-15820	444 S FLOWER ST	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.05189	-118.25546	REMODEL EXISTING OFFICE SPACES ON THE 34TH FLPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31706	17041-10001-29508	777 S SANTA FE AVE	90021	14	124-5A217 323	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			PC Approved	02/08/2018 12:00:00 AM	ADDRESS	34.03354	-118.23024	"REVISIONS ( 02/08/18 ) TO PERMITTED SET OF PLANS: REPLACE DIST BOARD ""MSC"" WITH CB RATED 1600AF/1000AS SET AT 1000A  TO SUPPLY PNL ADB2q ; CHP1 IS REFED FROM ADB2a; PNLS/XFMRS  CDB2/CT2  AND CDB1/CT1 ARE REMOVE; LOAD CALCULATIOND ARE REVISED TO REFLECT CHANGES((((((((((PC FOR POWER ONLY FOR CORE AND SHELL UPGRADES. REUSING EXISTING BUILDING WITH SOME UPGRADES. SOME DISTRIBUTION EQUIPMENT TO REMAIN AND REBUILDING SOME NEW AS SHOWN ON PLANS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31707	17041-20000-46609	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Lighting improvements to Westfield Topanga Canyon Mall.  Adding new lighting to existing panels.  Plan check for indoor energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31708	14041-10000-19299	13455 W CUMPSTON ST	91401	4	174B157   939	2344010006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.16969	-118.42642	Installation of roof mounted solar PV system.  Total size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31709	12041-20000-24318	448 S HILL ST 1301-1318	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM			PC Approved	10/11/2012 12:00:00 AM	ADDRESS	34.04896	-118.25139	Plan check for energy and emergency lighting. Office space. 13th floor, 1301 and 1318. 2764 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31710	17041-10000-45095	19401 W BUSINESS CENTER DR	91324	12	195B117    41	2783025072	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.23152	-118.55592	REPLACE EXISTING INDSOOR & OUTDOOR FIXTURES WITH LED FIXTURES. T-24 ONLY. Total area: 86,750 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31711	17041-20000-05773	10404 N SEPULVEDA BLVD	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/19/2017 12:00:00 AM	PIN	34.25931857	-118.46630746	TENANT IMPROVMENT TO RETAIL SPACE (T-MOBILE).  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31712	14041-20000-16374	19331 W BUSINESS CENTER DR	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.23118	-118.55466	New 1000A service, switchboard, panel, and branch circuits for Tampa Medical Plaza.  New indoor/outdoor lightings.  Plan check for power and energy. core and shell onlyplan check time extension filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31713	11041-10001-11041	145 S SPRING ST	90012	14	130-5A213  30	5149001003	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM			PC Approved	02/24/2012 12:00:00 AM	ADDRESS	34.05196	-118.24563	REPLACING EXISTING & OLD MCCD WITH NEW DISTRIBUTION PANEL.  ALL NEW MOTOR CONTROL PANELS TO BE USED WITH EXISTING EQUIPMENT LOADS.  PLAN CHECK FOR POWER.(((((((((((((((2-24-12  change og feeder and breaker, changes made to previously approved set))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31714	16041-10001-21831	3921 N LAUREL CANYON BLVD	91604	2	162B165   437	2369013019	R1-1-RFA-RIO, R1-1VL-RFA-RIO, [Q]RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.14179	-118.39477	CHANGE TO APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF DEVICES TO MEET THE FIRE DEPT APPROVAL. ADDED SD FOR HALLWAYS. PC AND PERMIT FOR NEW DEVICE COUNTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31715	19041-10000-00294	7503 N BALCOM AVE	91335	3	186B129   529	2120029031	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.20678	-118.52092	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 14 MODULES (Q-PEAK 315W) , 14 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 4.41KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31716	14041-10000-35352	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Issued	03/06/2015 12:00:00 AM	ADDRESS	34.22847	-118.55614	NEW FIRE ALARM SYSTEM FOR  A NEW MIXED USED APARTMENT BUILDING. 953 DEVICES AND ONE FIRE ALARM APNEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31717	16041-10001-12302	1703 N WILMINGTON BLVD	90744	15	036B201   145	7414006015	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM			PC Approved	06/17/2016 12:00:00 AM	ADDRESS	33.79709	-118.27541	Recheck for lost set of plans.     PV1 NEW ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTER. (16) MODULES AND (16) MICRO INVERTERS. TOTAL SYSTEM SIZE  IS 4KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31718	18041-10000-40164	624 S GRAND AVE 1610	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	PLANCHECK FOR POWER AND ENERGY. INSTALLING MEDIUM VOLTAGE SWITGEAR AND LIGHTING IN ELECTRICAL ROOM. SUITE 1610	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31719	19041-20000-39547	6983 S TROLLEYWAY	90293	11	096B149   655	4116033035	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	33.95631	-118.44948	Install 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31720	14041-10001-12755	13604 W LEMAY ST	91401	2	180B157   213	2329001040	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.19255	-118.42933	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.[[PV1, INSTALL 5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL,  WITH OTIMIZEERS AND TRANSFORMERLESS INVERTER.]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31721	10041-10000-10586	300 E WATER ST	90744	15	027B209   227	7440010***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2947.00	Electrical	Electrical	Public Safety Only			06/04/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	33.76636	-118.25616	FIRE WARNING SYSTEM TO BE INSTALLED AT THE PORT OF LA NEW POLICE STATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31722	19041-20000-42979	12600 W CARL ST Unit # 34	91331	7	210B161   814	2536011***	(Q)RD2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Issued	10/22/2019 12:00:00 AM	ADDRESS	34.27403	-118.40742	Plan check for PV roof mounted system, PV system size: 5.18KW DC, 4.667KW AC with 14 PV Modules and 14 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31723	19041-10000-10869	2445 E 12TH ST A	90021	14	120A217    96	5168003013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.02277	-118.22852	Design build: Energy plan check for an office T.I located in the 1st and 2nd floor of a commerial building. Scope inlcudes new lighting and equipment with a total area of 6967-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31724	11041-20000-05739	6255 W SUNSET BLVD #909	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	05/26/2011 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check T24 Energy/emergency lighting for office TI suite #909	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31725	16041-10000-42013	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.04443	-118.29612	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 54000 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31726	14041-10000-21963	200 WORLD WAY Terminal 2	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for power and lighting.  Total area = 3,921 sq. ft.T.I. to LAX terminal 2.  Installation of emergency lighting, recepticles, fire alarm system (11 notification devices), and panelboards (total connected load = 450 A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31727	19041-20000-02236	21914 W VENTURA BLVD	91364	3	171B101   179	2169003015	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.16819	-118.60439	New 400A 240/120V 1ph-3w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31728	17041-10000-18026	10993 W WELLWORTH AVE 1-8	90024	5	132B149   175	4324003010	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	05/31/2022 12:00:00 AM	ADDRESS	34.05634	-118.44604	PC FOR FA SYSTEM FOR 8 UNIT APARTMENT. USING MAIN PANEL AND 86 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31729	17041-10001-35433	9143 N DE SOTO AVE	91311	12	198B109   160	2746009023	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM			Verifications in Progress	09/25/2019 12:00:00 AM	ADDRESS	34.23672	-118.58873	PLAN CHECK FOR RECHECK OF FITNESS CENTER - CHANGES INCLUDED ON SINGLE LINE DIAGRAM, PANEL SCHEDULES, RELOCATION AND ADDITIONS OF LOADS, LIGHTING LAYOUT AND SERVICE LOAD CALCULATIONS. CHANGES ARE >50% OF SUBMITTAL   ORIGINAL PERMIT CHANGE OF USE FROM RETAIL TO FITNESS CENTER (8227 SF) TI, SCOPE OF WORK INCLUDES NEW SERVICE, LIGHTING AND RECEPTACLES. 120/208V, 3PH, 4W, 1600A. TOTAL SQ. FT. 34003	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31730	18041-10000-37551	8552 N GLENCREST DR	91352	2	192B177    79	2404011022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.22608	-118.36096	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.60KWdc / 6.00KWac. (24)MODULES- CANADIAN SOLAR CS6K-275P (24)OPTIMIZERS-SOLARDGE P320 OPTIMIZERS(1)INVERTERS-SOLAREDGE SE6000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31731	16041-20000-44059	8400 N BELLINGHAM AVE	91352	6	192B165   361	2633004009	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.22304	-118.39911	PV1.  Install 12.78 kW roof mounted grid tied PV system.  (44) modules with (2) 6 kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31732	10041-10000-16354	2101 E PACIFIC COAST HWY HCU	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	03/29/2011 12:00:00 AM		Permit Finaled	06/01/2012 12:00:00 AM	ADDRESS	33.79173	-118.23549	Install a new 60 Amp Circuit for a Pre-Fabricated Gas Analyzimg equipment in a Class I Div 2 of the HCU of Tesoro refinary.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31733	12041-10000-28688	2101-2133 S SAWTELLE BLVD	90025	11	126B153   909	4260002029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.03929	-118.44248	PLAN CHECK FOR TITLE 24. INSTALLING 8 OUTDOOR SCONCES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31734	15041-10001-43443	9510 S VERMONT AVE	90044	8	093A199    65	6039017075	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM			Reviewed by Supervisor	04/23/2018 12:00:00 AM	ADDRESS	33.94986	-118.29139	Full plan check for an expired approved lost plan. Other than service change from 1200A to 800A , all new equiptment remain the same. B#15014-10000-05927((( ADDITION TO EXISTING COMMERCIAL BLDG. ; new 1200A service and swbdNEW ADDITION DOES NOT HAVE BUILD-OUT YET)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31735	18041-10000-33087	7106 W FOOTHILL BLVD	91042	7	202-5A201 552	2564002002	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM			PC Info Complete	08/29/2018 12:00:00 AM	ADDRESS	34.24785	-118.28617	Plan check for T24 only, TI on existing commercial space. Total area: 1,050 sq.ft(18016-20000-24925)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31736	18041-10001-12178	4650 S LINCOLN BLVD	90292	11	105B153   132	4224014024	[Q]C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM			PC Approved	07/05/2018 12:00:00 AM	ADDRESS	33.98174	-118.44003	T-24, PC FOR EXTERIOR SIGN LIGHTING FOR CEDAR SINAI. SCOPE INCLUDES INSTALLING THREE ILLUMINATED WALL SIGNS AND 2 ILLUMINATED MONUMENT SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31737	14041-20000-20817	16531 W ARMSTEAD ST	91344	12	213B137   222	2610022001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.28239	-118.49233	PV1Central/string inverter standard plan.Install roof-mounted solar array on SFD. System size: 4.2kW(1) Power-One #Aurora PVI-4.2-OUTD-S-US-Z-A transformerless inverter(19) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31738	17041-10000-45099	3333 W SAN FERNANDO ROAD	90065	13	153B209   120	5458007012	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.11836	-118.2491	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31739	11041-20000-14771	1441 N EASTLAKE AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	07/15/2011 12:00:00 AM	ADDRESS	34.06118	-118.20631	Ti in Room 5517. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31740	14041-20000-32572	9750 S AIRPORT BLVD	90045	11	093B169   274	4125024020	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	33.94789	-118.38556	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT  IN LOBBY,  REGISTRATION DESK,  PUBLIC RESTROOMS.  4439 SQFT, EMERGENCY EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31741	14041-10001-00531	900 S CRENSHAW BLVD	90019	4	132B189   914	5092003022	CR-1VL	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			07/28/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.05612	-118.32202	PLANS WERE REVISED TO SHOW THE USE OF ALUMINUM TYPE SE CONDUCTORS AS FEEDERS TO APARTMENTS PANELBOARDS AND ALUMINUM TPE THHWN AS FEEDERS  FOR HOUSE PANELS AND LOADS.; USE 15A BRANCH CIRCUITS FOR LIGHTING IN THE UNITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31742	17041-10000-18477	15521 W CABRITO ROAD	91406	6	189B145   116	2654040019	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.21723	-118.47077	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31743	15041-10000-36623	3630 S WELLINGTON ROAD	90016	10	120B185  1353	5046021013	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.02218	-118.33817	PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE IS 4.2 KW. (14) MODULES AND (1) INVERTER. (14) HANWHA QPRO-G4 260(1) SMA AMERICA SB 3800TL-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31744	14041-20001-13141	8828 W KEY ST	90035	5	129B169   742	4305020009	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	34.04981	-118.38579	Expedite fee for rooftop solar	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31745	17041-10000-33819	22103 W VANOWEN ST	91303	3	183B101   641	2024007019	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Issued	09/21/2017 12:00:00 AM	ADDRESS	34.19392	-118.60857	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31746	18041-20001-42897	6407 W MARYLAND DR	90048	5	135B173   453	5510013002	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.06741	-118.36794	Expedite per applicant requestPlan check for PV roof mounted system with Energy Storage System. PV system size: 8.25kW DC, 7.01kW AC with 25 PV Modules and 1 inverter(7.6kW) with 9.8kW LG battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31747	15041-30001-37860	5919 S VAN NESS AVE	90043	8	105B189   261	4005027019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM			PC Approved	12/01/2015 12:00:00 AM	PIN	33.98672606	-118.31795894	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 4.2 kWac.  Single inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31748	15041-10000-39354	453 N WESTMORELAND AVE	90004	13	141B197  1087	5539034020	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.0793	-118.28813	FA, Adding 1 new control panel and 12 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31749	11041-20000-18054	5219 N CRANER AVE	91601	4	171B173   519	2416004023	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Public Safety Only			08/24/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.1655	-118.36924	New fire alarm system for existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31750	14041-10000-07031	12950 N BRADLEY AVE	91342	7	222B149   430	2506011002	M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.30531	-118.45936	T24 ONLY REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW  FLORESCENT FIXTURES, TOTAL AREA 22104 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31751	14041-20001-17367	7036 N VAN NUYS BLVD	91405	6	183B149   254	2217007018	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.1987	-118.44853	[[[8/9/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ARE CLOUDED AND LIMITED TO RELOCATING EMERGENCY GENERATOR FROM ROOF TO OUDOOR ON 1ST FLOOR, USING MC CABLES FOR FLOOR BRANCH CIRCUITS, CHANGING UNIT FEEDER CABLES TO #6 ON SECOND FLOOR UNITS, REDUCING LIGHTING INSIDE UNITS]]]]]]]Power and energy plan check for 5 stories new built with 132 units assisted  living apartment without kitchens, central kitchen included.  2008 TITLE 24  CODE CYCLE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31752	16041-10000-32155	400 WORLD WAY T4 POC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM			PC Approved	09/09/2016 12:00:00 AM	ADDRESS	33.94221	-118.40701	Plan check Title 24 only LAX Terminal 4 POC. Total area: 1081 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31753	18041-10000-10881	3235 N CRAIG DR	90068	4	159B181    11	5579004020	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Closed	04/03/2018 12:00:00 AM	ADDRESS	34.13602	-118.3428	PLAN CHECK FOR FOR FIRE ALARM SYSTEM WITH FIRE ALARM COMMUNICATION PANEL WITH 4 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31754	16041-20000-17139	16150 W SHERMAN WAY	91406	6	183B141   121	2224009035	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.20093	-118.48511	Plan check for a fire alarm system for a 2-story B-occupancy building. System consists of (1) FACP, (1) RPS, (2) annunciators, and (94) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31755	15041-20000-32716	811 E JEFFERSON BLVD	90011	9	117A207   194	5120028027	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.0145	-118.26291	PV1 SFD TOTAL SYSTEM SIZE 3KW AC USING CENTRAL INVERTER SYSTEM. USING A TOTAL OF 9 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31756	16041-10000-14761	4161 W 60TH ST	90043	8	105B181   534	4003004023	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	33.98541	-118.34857	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.5KWac.(30)MODULES-SOLARWORLD SW275 MONO BLACK(30)MICROINVERTERS-M250-602LL-S2X	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31757	16041-10002-06846	2300 N ALTO OAK DR	90068	4	153B193   438	5587008042	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	34.11179	-118.31337	CHANGE IN SYSTEM FROM 2 CENTRAL INVERTERS TO 1 CENTRAL INVERTER. TOTAL RATING NOW 11.4KW AC this is plan check only for change in system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31758	13041-10000-04389	20200 W SATICOY ST	91306	3	186B113   243	2114005032	C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04, 1347.20	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.20818	-118.57321	"Convert 36'9"" X 135'0"" irr-shaped portion (4319 sqft) of existing restuarant to retail, including T.I. to install demising walls to create 4 retail tenant spaces, and install rooftop mechanical equipment platforms.Service of 400A is existing; added load is less than 400A;dental office is existing"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31759	10041-20000-25890	9434 W CHEROKEE LANE	90210	5	150B165    67	4387032016	RE15-1-H, RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2010 12:00:00 AM	12/13/2011 12:00:00 AM		Issued	12/13/2011 12:00:00 AM	ADDRESS	34.11079	-118.40008	Plan check for new 1600A service and addition to existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31760	15041-10000-19860	1950 E 103RD ST	90002	15	091-5A215 138	6066005001	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM			PC Approved	06/24/2015 12:00:00 AM	ADDRESS	33.94298	-118.23783	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW ANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.****10/1: Applicant came with other sets of plan since this plan was lost. New application created***DM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31761	15041-20000-13769	2186 N MANDEVILLE CANYON ROAD	90049	11	138B133   496	4493003012	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.07624	-118.49874	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (19) modules, and (19) power optimizers. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31762	18041-10000-27165	403 W AVENUE 33	90031	1	142-5A221 168	5205003008	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.08398	-118.21683	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31763	16041-20001-08449	14755 W VENTURA BLVD	91403	4	166-5A149  15	2265001006	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	05/04/2016 12:00:00 AM	ADDRESS	34.15211	-118.4549	05/04/2016 Changes to an approved set of plans. Changes have been made to the light fixtures. All changes have been clouded and marked as Delta 1. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,226 sq. ft.Note: Building permit has been pulled under 16016-10000-04236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31764	16041-10000-41749	12450 W FOOTHILL BLVD	91342	7	216B161   530	2527022031	[Q]M1-1-CUGU, [T][Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.04	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.28562	-118.40722	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 55125 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31765	12041-10002-29023	10125 W VALLEY SPRING LANE	91602	4	165B181   478	2424035011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM			Corrections Issued	02/14/2013 12:00:00 AM	ADDRESS	34.14651	-118.35118	"(((((( Plans were approved for 1"" conduit size however the contractor is using a .75"" conduit.)))))New roof mounted PV1 for a single family. (use enphase 215, MODULES SHALL BE ISTED BY THE CITY OF LA RECOGNIZE TESTING AGENCY)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31766	12041-20000-25504	14747 N SAN FERNANDO ROAD	91344	12	228B133    49	2601011015	A1-1-O, [T][Q]M3-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Issued	10/24/2012 12:00:00 AM	ADDRESS	34.32306	-118.5027	Plan check for fire alarm system. 1 new panel and 71 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31767	16041-20001-29562	2020 N CUMMINGS LANE	90027	4	151-5A195 197	5589009032	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	34.10784	-118.30112	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (36) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31768	16041-20000-31420	18137 W MARILLA ST	91325	12	201B125   252	2764018021	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.24741	-118.52893	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222PV1.  Install 13.68 kW roof mounted PV system.  (48) modules with microinverters and AC combiner panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31769	12041-20000-17842	1510 N STANLEY AVE	90046	4	147B177   938	5550006023	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			Reviewed by Supervisor	08/14/2012 12:00:00 AM	ADDRESS	34.09848	-118.35597	TENANT IMPROVEMENT (E) RESTAURANT.  Assembly area, occupant load over 100. Plan check for electrical, emergency lighting and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31770	16041-20000-12009	8432 W MELROSE PL	90069	5	141B173   506	5528017033	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	34.08342	-118.37439	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR RETAIL. 2505 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31771	14041-10001-24938	13415 W BLYTHE ST	91402	6	189B157   437	2301020014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.21501	-118.42545	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31772	14041-20000-22688	17543 W CHATSWORTH ST	91344	12	207B129   401	2712027029	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.26507	-118.51683	TI for (E) commercial retail space.  Plan check for energy conservation standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31773	19041-20000-03884	14941 W DEVONSHIRE ST pv3	91345	7	204B149   210	2648001013	A2-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.25739	-118.45803	permit fee $0.00 by state senate bill NO. 1222pc for pv system. 34.3 kw DC and 30.9 AC. 98- REC350TP2S72 modules. 3 inverters (solaredge -se10000H). system is installed for a  church.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31774	14041-20000-16197	21021 W VENTURA BLVD 300-310	91367	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	PIN	34.16705846	-118.59120236	plan check for title 24 energy and emergency only for an existing commercial building 8700 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31775	18041-20000-17421	15632 W KINZIE ST	91343	12	201B141   297	2671007013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.24813	-118.4732	Plan check for PV roof mounted system, system size: 10.6kWac with 35 modules and 2 inverters(7.6kW and 3.0kW) connected to battery backup 9.8kWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31776	18041-20000-23636	11931 N ANCONA WAY	91326	12	216B109   344	2701086008	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.28947	-118.58587	PV1.  Install 11.7 kW DC roof mounted grid tied PV system.  (39) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31777	18041-10000-44613	5524 N WILBUR AVE	91356	3	174B121   527	2161003002	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM			Corrections Issued	12/20/2018 12:00:00 AM	ADDRESS	34.17155	-118.54459	NEW PV-2 (SOLAR SYSTEM ON COMMERCIAL BUILDING). SYSTEM SIZE 190.575 kW (DC-STC) / 150 kW AC ON  3 STEEL SOLAR CARPORTS, SYSTEM CONSIST OF (495) MODULES, (3) 50 kW INVERTERS, (1) 225 kVA STEPDOWN TRANSFORMERB# 18010-10000-05616	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31778	12041-20000-02014	12153 N NUGENT DR	91344	12	216B129    61	2608033020	RE15-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.29194	-118.51515	Photovoltaic system on the  roof of a single family dwelling, using solar roofing tiles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31779	10041-10000-16304	5230 N LANKERSHIM BLVD	91601	4	171B173  1387	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.16571	-118.37485	TI IN AN EXISTING RESTAURANT. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS. PERMIT IS FOR NEW SERVICE, PANELS & CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31780	13041-20000-33436	11526 W BURBANK BLVD	91601	2	174B169   866	2350004039	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.17199	-118.3832	REMODEL EXIST 2-STORY OFFICE BUILDING. NEW ELECTRICAL BUILD OUT. RELOCATION OF EXISTING 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31781	14041-20001-19844	455 S LORRAINE BLVD	90020	4	135B189   602	5504003011	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM			PC Approved	08/12/2014 12:00:00 AM	ADDRESS	34.06565	-118.32015	Expedite fee for residential rooftop solar	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31782	19041-20000-26475	1717 E 7TH ST	90021	14	124-5A215  56	5164022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.03495	-118.23573	PV3.  Install 80.3 kW DC / 66.6 kW AC roof mounted grid tied PV system.  Scope of work includes (220) modules with 6 inverters and a 200A sub panel.$0 permit fee due to SB1222 and AB1414COMPLY WITH DEPARTMENT ORDER effective date10/25/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31783	15041-20000-10040	1200 S GRAND AVE TEMP	90015	14	126A207   131	5139023039	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Issued	05/14/2015 12:00:00 AM	ADDRESS	34.03989	-118.26331	PC FOR NEW TEMP SERVICE FOR CONTRUCTION SITE. NEW 800A UNDERGROUND IN METHANE ZONE. PC FOR POWER ONLY. NO ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31784	16041-10000-41817	227 N TIGERTAIL ROAD	90049	11	135B141   841	4403011026	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.06229	-118.47957	FULL PC FOR SINGLE FAMILY.NEW SERVICE OF 800A 120/240VNEW PANELS AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31785	11041-10000-20854	542 S BROADWAY	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	01/11/2012 12:00:00 AM	ADDRESS	34.047	-118.25144	T.I. to an existing retail space, with new signage.  PLAN CHECK ONLY for energy, with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31786	11041-20000-21531	6351 W LONGVIEW AVE	90068	4	151-5A187 332	5576018041	R1-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.10838	-118.32825	5.4KW PV SYSTEM SINGLE FAMILY DWELLING. PERMIT INCLUDES UPGRADING EXISTING 100A TO NEW 200A SERVICE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31787	13041-10001-09992	353 S BROADWAY	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM			PC Approved	09/08/2015 12:00:00 AM	ADDRESS	34.04991	-118.24934	Changes to approved set. Scope includes: change of fixutre type, in corridor and exit ways. No changes in delta 1.  (((PLAN CHECK FOR POWER AND ENERGY. EXISTING BUILDING WITH NEW 800A SERVICE AND ELECTRICAL SYSTEM (CORE AND SHELL). MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED. ALL TENANTS LOADS WILL BE FUTURE PLAN CHECK SUBMITTAL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31788	10041-20000-20867	2941 W 70TH ST	90043	8	102B189   584	4008011058	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01, 2352.02	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.97648	-118.3254	Plan check power, energy, and fire alarm system for new charter school.  NOTE: Filed for variance to have two services to a building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31789	14041-20000-31645	1351 N SPAULDING AVE	90046	4	147B177  1301	5551030010	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.09578	-118.35721	PV1MICROINVERTER STANDARD PLAN SYSTEM SIZED 7.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31790	18041-20000-46188	1640 E MARENGO ST 1st Floor	90033	14	133-5A223  37	5201001001	C4-1-CUGU, P-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2033.00	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM			PC Info Complete	12/05/2018 12:00:00 AM	ADDRESS	34.05983	-118.21397	Plan check for Title 24 only in existing space T.I. common area. Total area: 1266 sq ft.B#18016-10000-35700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31791	19041-20000-51828	3300 S SEPULVEDA BLVD J 26	90034	5	120B157   630	4251016***	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Apartment			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Issued	12/16/2019 12:00:00 AM	ADDRESS	34.02268	-118.42469	Plan check for PV roof mounted, PV system size: 3.35KW DC, 2.847KW AC with 10 PV Modules and 10 micorinverters Conected to existing sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31792	19041-20000-15613	3036 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31793	17041-20000-18634	5060 N AMESTOY AVE	91316	5	171B133   648	2258014006	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.16199	-118.50531	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 4.2 kWac and consists of (1) inverter, (16) modules, (1) load center, and (1) Tesla Powerwall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31794	13041-10001-25507	5500 W RIDGE OAK DR	90068	4	153B193   161	5580027018	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.1143	-118.30983	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. SYSTEM SIZE: 12.54 KW SYSTEM. 44 MODUELES. 44 SOLAR EDGE OPTOMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31795	16041-30000-37834	10625 W TABOR ST	90034	5	120B161   930	4314011014	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.02357	-118.41014	Installation of fire alarm system in new 5 story 32 unit apartment building.  Total system size = 115 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31796	11041-10000-18340	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMOPROVEMENT IN RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31797	10041-20000-09302	13910 W FOOTHILL BLVD	91342	7	225B153   354	2509003022	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.04	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	12/07/2010 12:00:00 AM	ADDRESS	34.31187	-118.43649	dental office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31798	11041-10000-09557	2311 W 10TH ST 1-27	90006	1	130-5A201 366	1305A201		Central				2095.10	Electrical	Electrical	Apartment			05/11/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.05314	-118.28223	NEW FIRE ALARM SYSTEM FOR A NEW 4-STORY CONDOMINIUM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31799	15041-20000-30286	6301 N OWENSMOUTH AVE 9th Floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.18467	-118.60176	Title 24 plan check only.  Total area = 19,559 sq. ft.  T.I. to existing commercial highrise office space.  New lighting and recepticles.  Total connected load for this floor is less than 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31800	17041-10000-20945	11600 N ELDRIDGE AVE	91342	7	213B169  1018	2530001019	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.28073	-118.38369	PC for new fire alarm system with 351 devices, 1 FACP and 7 RPS panels in a two story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31801	13041-20001-26878	16208 W ADDISON ST	91436	5	171B137   400	2260014010	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2013 12:00:00 AM			Reviewed by Supervisor	10/16/2013 12:00:00 AM	ADDRESS	34.16179	-118.48619	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 8.3 KW AC USING ENPHASE MICROINVERTER NONSTANDARD PLAN. 3 STRINGS. 39 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31802	16041-10000-04795	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	PC FOR POWER AND ENERGY.  ADD THEATER STRUCTURE TO (E) MUSEUM/RESTAURANT/RETAIL/OFFICE BLDG. 2 NEW SERVICE WITH 3000A, 5000A , ADDITION OF NEW PANELS AND DEVICES. B# 13014-10000-03762	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31803	17041-10000-32169	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR FA SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 207 FA DEVICES, AND TWO FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31804	18041-10000-13043	18607 W HILLSBORO ROAD	91326	12	207B121   803	2728030001	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.26038	-118.54053	58$ permit fees due to seante bill 1222PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 10.85 KW.  35 PANELS TOTAL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31805	15041-20000-10046	12460 W OSPREY LANE unit #1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	Plan check for PV roof mounted system for tri-plex unit #1 with system size: 1.84kW. PV clearance shall apply to unit #2 and #3 for address 12460 Osprey Lane, Los Angeles CA 90094	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31806	15041-20000-14892	6606 W 5TH ST	90048	5	135B173   367	5510014035	R1-1-O-RFA	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.06838	-118.37099	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Central inverter system (standard plan used)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31807	12041-10000-27828	12734 N JIMENO AVE	91344	12	222B133   579	2602021008	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Expired	12/22/2014 12:00:00 AM	ADDRESS	34.30218	-118.5024	PV1 2.45 KW ROOF MOUNTED SOLAR SYSTEM. ENPHASE 215 MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31808	17041-20000-21487	6470 N VAN NUYS BLVD ste A	91401	6	180B149   643	2237023018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.18825	-118.44846	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31809	14041-20000-02818	15935 W GRESHAM ST	91343	12	195B141   407	2672024014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.23116	-118.47966	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE1 11KWAC. ZERO FEES DUE TO 2012 SENATE BILL NO 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31810	17041-10001-35442	261 N ROSEMONT AVE	90026	13	138A205   266	5157012038	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.07088	-118.27102	Fee expedited per applicantInstall new rooftop solar on a commercial building. (114) modules with P600 optimizers, (2) 14.4 kW inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31811	14041-20000-25135	6600 N TOPANGA CANYON BLVD #8	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Closed	03/02/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI for (E) commercial retail space in shopping mall.  4,158 sq. ft.  Plan check for energy (2013 Building Energy Efficiency Standards).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31812	15041-10001-00392	6201 W HOLLYWOOD BLVD 110	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	ADDITION OF DIMMER PANELS;NEW CIRCUITSCHANGES ARE CLOUDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31813	17041-10001-15276	10250 W SANTA MONICA BLVD #1970	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	This is Plan check only. Changes to approved set noted as Delta-4 : (1) add receptacles, (2) revise light fix. wattage, (3) revise load calc., (4) revise T24 calc.       Permit is covered under master 17041-10000-15276	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31814	15041-10000-27012	12700 W MILLENNIUM #47	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1 1.5KW roof-mounted system with (6) (SPR-X20-250 Sunpower AC - modules interconnecting through a sub-panel. Application is for plan check only, permit fee is paid under 15041-90000-26265.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31815	18041-20000-15237	10848 W KESWICK ST	91352	2	186B173    50	2409015011	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.21015	-118.36763	PV1.  Install 10.44 kW DC/9.31 kW AC-CEC grid tied roof mounted PV system.  (29) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31816	15041-20000-33953	7320 N WOODLAKE AVE SUITE 320	91307	12	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM			PC Info Complete	11/19/2015 12:00:00 AM	ADDRESS	34.20263	-118.63189	FULL PC. TI ON EXISTING COMMERCIAL BUILDING (MEDICAL OFFICE, NON-OHSPD 3, B OCCUPANCY) AT SUITE 320. SCOPE INCLUDES SPLITTING UPS INTO THREE PANELS WITH AN ADDITION OF ONE NEW SUBPANEL. TOTAL AREA IS 2,859 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31817	15041-10000-16396	12515 W OSPREY LANE #2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	33.97893	-118.41131	((((5/28/2015))))PV1 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 3 SIZED 1.84KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19527.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31818	16041-10001-27270	4225 S CENTRAL AVE	90011	9	114A209   153	5115019033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	05/26/2017 12:00:00 AM	ADDRESS	34.00695	-118.25669	05-26-2017 Changes to an approved set of plan. Changes include remove the bar area. Changes apply to delta 3 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31819	13041-10000-25702	1144 S ABBOT KINNEY BLVD	90291	11	108B145  1194	4238003020	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	33.99133	-118.46923	TITLE 24 PLAN CHECK ONLY. MERCANTILE. EXIT SIGNS EXISTING TO REMAIN. 1038 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 1 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31820	14041-10001-01591	2226 S RAYMOND AVE	90007	8	123B197   302	5054018020	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.03547	-118.29741	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 1.5 kW DC roof-mounted solar array on a two stories multi units home, interconnect with exsisting service panel. (1) Transformerless inverter(s): POWER-ONE AURORA PVI-3--OUTD-S-US. (6) Modules TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31821	16041-10000-45696	976 N WESTERN AVE	90029	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Info Complete	01/13/2017 12:00:00 AM	ADDRESS	34.08812	-118.30897	PC FOR ENERGY ONLY, TI TO (E) RESTAURANT. INCLUDING BATHROOMS, DINING AREA. CONNECTED LOAD< 400A. OCUPANT LOAD IS LESS THAN 100. TOTAL AREA 2710 SQ FTB# 16016-100000-18440	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31822	17041-10000-29549	718 E 40TH PL	90011	9	115-5A207 318	5114007011	RD2-1	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.01001	-118.26302	PC FOR PV SYSTEM USING 5KW INVERTER WITH 16 MODULES AND POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31823	17041-10000-25201	10250 W SANTA MONICA BLVD # 1025	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Issued	11/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	New restaurant- Saint Marc-FULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31824	14041-20000-05057	6439 N BONNER AVE	91606	2	180B173   765	2336005004	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.18779	-118.37383	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31825	15041-10000-22719	800 W WILSHIRE BLVD 4TH FLR-RSTRM	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Issued	07/27/2015 12:00:00 AM	ADDRESS	34.0493	-118.25841	TITLE 24 TO AN EXISTING OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS IN RESTROOMS. PC FOR ENERGY ONLY. TOTAL SQ. FT. = 370.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31826	18041-10000-22804	6926 W MELROSE AVE	90038	5	141B181   662	5525018026	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.08331	-118.3424	PLAN CHECK FOR TITLE 24 ONLY FOR - RENOVATION AND IMPROVEMENTS AT 1ST AND 2ND FLOOR TO AN EXISTING COMMERCIAL OFFICE/ASSEMBLY BUILDING - TOTAL AFFECTED AREA = 6073 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31827	19041-10000-11990	4451 N BEN AVE	91607	2	165B165   112	2364013028	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	06/15/2019 12:00:00 AM	ADDRESS	34.15198	-118.39444	(ePlan) Revision to online permitted rooftop solar system, permit# 18041-90000-44607. Scope includes adding one more inverter to existing design to total now 2 Central Inverters (SE7600A-USS StoreEdge and SE3000H-US). System size is 10.6kWac and 11.52kW DC.  Covered on the existing permit is 36 modules (Panasonic Group VBHN320KA03 320W) and 36 Optimizers (SOLAREDGE P400)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31828	16041-20000-28309	950 W 190TH ST 3rd Floor	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	33.85814	-118.29219	Plan check for energy only. TI to offices in existing commercial building. New lighting and receptacles. 1,148sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31829	15041-20000-09152	10042 N ARLETA AVE	91331	6	204B153   804	2645013017	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Expired	04/21/2017 12:00:00 AM	ADDRESS	34.25298	-118.43731	Plan check for PV1 roof monted system with central inverter 3.8kW and 14 modules (327W)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31830	13041-20000-20741	12045 W KESWICK ST	91605	6	189B165  1087	2317001010	(T)(Q)R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	Apartment			08/05/2013 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.21041	-118.3962	NEW 32 UNIT APARTMENT BUILDING. 3 HABITIBLE STORIES WITH 1 SUBTERRANIAN GARAGE. WILL PULL FIRE ALARM VARIANCE AT FINAL STAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31831	09041-10002-03947	8487 W 3RD ST BLDG  D	90048	5	138B173   683	5511013021	(T)(Q)C2-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM			PC Approved	02/11/2010 12:00:00 AM	ADDRESS	34.07344	-118.37533	Revisions to approved set of plans- on sheet E-5 ( panel schedules ) ,  there are changes to the branch circuit ratings of some loads, new ac unit, deletion of some loads and changing loads using the existing branch circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31832	16041-10001-19570	12011 N BRADFORD PL	91344	12	216B133   250	2606022012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.28934	-118.50407	FEES ARE $0 DUE TO SENATE BILL 1222. 07/26/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE RELOCATING 2 TWO MODULES ON THE ROOF LAYOUT.NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-19570(((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(39)MODULES-CANADIAN SOLAR CSP6P-265P(39)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE TECH 10000A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31833	19041-10000-06998	407 S COLYTON ST	90013	14	127-5A215 258	5163025004	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM			PC Info Complete	06/13/2019 12:00:00 AM	ADDRESS	34.04317	-118.23659	FULL PLAN CHECK FOR A CHANGE OF USE TO ART GALLERY LOCATED IN A SINGLE STORY BUILDING (1 OUT OF 4 BUILDING IN THE SAME PARTIAL WITH DIFFERENT ADDRESS). SCOPE INCLUDES AN EXISTING SERVICE SUPPLYING A NEW 800-AMP SWITCHBOARD,  LIGHTING (IN/OUTDOOR) AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 39,712-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31834	16041-20000-13558	22657 W FRIAR ST	91367	3	180B097   676	2039021013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Expired	05/21/2018 12:00:00 AM	ADDRESS	34.18558	-118.62087	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.28 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31835	16041-10000-00597	1057 S OLIVE ST	90015	14	126A207    32	5139010001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.04109	-118.26098	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE/SALES/BATHROOM AREA). SCOPE INCLUDES NEW LIGHTING TO A 'TEN SALES CENTER.'TOTAL AFFECTED AREA IS 3797 SQ. FT.NOTE: FEES PAID UNDER 15041-10000-39105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31836	13041-10000-01885	380 WORLD WAY Space T50	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	LAX  Thomas Bradley International  Terminal level 4. space T50-RPROPOSED 1470 SQFT.  TENANT IMPROVEMENT  FOR RETAIL CONCESSION  SPACE (kitson).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31837	18041-10000-47576	8437 W FOOTHILL BLVD	91040	7	207B189  1098	2555025009	C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	Commercial			12/14/2018 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	05/22/2024 12:00:00 AM	ADDRESS	34.25987	-118.31695	PC FOR NEW 2-STORY OFFICE BLDG TITLE 24, TOTAL SQFT = 5176	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31838	10041-10000-11141	8723 W ALDEN DR 1ST FLOOR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/11/2010 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.0754	-118.38272	"TI IN THE MICROBIOLOGY LAB ON THE 1ST FLOOR OF ""CEDARS SINAI MEDICAL CENTER"".  PLAN CHECK IS FOR POWER AND ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31839	13041-20001-27430	13031 W JEFFERSON BLVD Suite 600	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	Changes from previously approved.  Changes include location of equipment and load calculation.  Plan check for power only. no permit to be issued from this application*****Previous Description*****TI to an existing office building.  New panels, loads, lighting.  Load is greater thank 400 amps.  FULL PLAN CHECK.  Permit fees are $30,428.13	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31840	18041-10001-47011	4252 S CRENSHAW BLVD	90008	10	114B185   958	5024017007	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.00668	-118.33443	"PLAN CHECK ONLY,. Changes to an approved set of plans noted under delta 3 only. Scope of work includes the change of AIC rating and feeder size for ""MDB-1, 2, 3"" from 100kaic to 65kaic. ______________________________________________________Full plan check for a 4-story, 111-unit FACTORY BUILT STATE APPROVED HOUSING apartment building.Scope includes 2000-Amp 120/208v 3phase 4-wire service. Bld application: 18010-10000-02786FA system under #19041-10000-05036"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31841	14041-10000-11515	1900 S FIGUEROA ST	90007	9	124-5A205 238	5126008018	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.03412	-118.27196	TI FOR EXISTING DTLA PORSCHE DEALER. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31842	17041-10000-23278	8500 W BEVERLY BLVD UNIT 112	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR RESTAURANT TI. PC FOR POWER AND ENERGY. NEW 600A DISTRIBUTION PANEL, POWER AND LIGHTING PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31843	18041-10000-00482	1601 E OLYMPIC BLVD BLDG. 300	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.02923	-118.24056	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLYVALLEY PRODUCE #307	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31844	16041-10000-34571	3335 S FIGUEROA ST	90007	9	120A203   503	5123009042	[Q]C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.02224	-118.28008	T-24, PC FOR ENERGY ONLY. INTERIOR T.I. TO EXISTING RESIDENT AMENITIES AREA. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 7132 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31845	17041-20000-32831	21201 W OXNARD ST #B	91367	3	177B105    67	2149005043	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.17943	-118.59394	Plan check for energy only. Project site is an existing commercial tenant space. Project scope is change of use from industrial to sound studios/offices and a tenant improvement. Total lighting area = 8,045 sq. ft.Note: Building application has been generated under 17016-10000-24861	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31846	15041-20000-35457	8001 N VENTURA CANYON AVE	91402	6	189B157   306	2213019040	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.21649	-118.42885	Replacement of electrical system in Kaiser Permanente office Building 6.Re-feeding electrical services, replacement of switchgear, panelboards and refurbishing (E) Electrical equipments. Derating Main service from 1200A to 1000A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31847	14041-10000-04886	7036 N KEOKUK AVE	91306	3	183B113   294	2135003014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Issued	02/21/2014 12:00:00 AM	ADDRESS	34.19864	-118.57421	PV1, INSTALL 4.33 KW DC ROOF-MOUNTED MICRO INVERTER SOLAR ARRAY ON A 1-STORY HOME.( 17) SUNMODULE SW 255 (17) ENPHASE M215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31848	12041-20000-10867	6901 W PARSONS TR	91042	7	207B201   104	2553013004	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM			Reviewed by Supervisor	07/06/2012 12:00:00 AM	ADDRESS	34.2642	-118.28262	Changes from previously approved plans 12041-20000-02059(((owners do not want to commit with changes. all installtion will be in accordance to original applicaton and plan check number. disregard this application))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31849	17041-10000-36220	944 E PICO BLVD # 5	90021	14	123A211   265	5132018034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.03051	-118.24925	INTERIOR ALTERATIONREPLACE HID LUMINAIRES WITH LED      TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31850	18041-10002-14610	3260 S CLUB DR	90064	5	123B165   698	4316030025	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.0328	-118.40233	SUPPLIMENTAL FOR THE THREE ENERGY STORAGE SYSTEMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31851	11041-10000-08833	555 S FLOWER ST 8th floor	90071	9	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM	06/10/2011 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	34.05048	-118.25755	Ti in an existing office on the 8th floor. EPC is for power & Energy.  <<<<VARIANCE SUBMITTED TO SEPERATE THE FIRE LIFE SAFETY SYSTEM.>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31852	16041-30000-20783	444 S FLOWER ST Restrooms	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is the restrooms on the 16th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 598 sq. ft.Note: Building permit has been issued under 16016-10000-04709	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31853	10041-20000-02444	1985 E ZONAL AVE #503, 503a	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	05/20/2010 12:00:00 AM	ADDRESS	34.06159	-118.20463	conference room remodelEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31854	13041-10000-22120	5950 S ST ANDREWS PL	90047	8	105B193   169	6001014008	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	33.9866	-118.31122	PLAN CHECK POWER FOR ONE 18000 GALLON PROPANE TANK AND DISPENSERS IN A BUS LOCATION. CLASSIFIED HAZARDOUS LOCATION. SITE LOCATED IN METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31855	17041-20000-01860	6200 N CANOGA AVE #201	91367	3	177B105   127	2149001035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.1833	-118.59719	Plan check for Title 24 only. Project site is the partial 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,792 sq. ft.Note: Building permit has been pulled under 16016-10000-29996	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31856	18041-30000-06307	1338 N FORMOSA AVE 1-25	90046	4	147B181  1056	5548021072	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.09551	-118.34613	NEW FIRE ALARM SYSTEM FOR A 3 STORY BUILDING,(1) FIRE ALARM PANEL AND (120) FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31857	11041-20000-02107	10960 W WILSHIRE BLVD 11th fl	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/02/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	energy plan check 11th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31858	18041-20000-29650	4400 N CAHUENGA BLVD	91602	4	165B177   345	2424002005	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.15059	-118.36128	Plan check for a fire alarm system for a 3-story, 10-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (52) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31859	14041-10000-35145	158 N CARMELINA AVE	90049	11	132B141   270	4405005013	RS-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Expired	03/30/2017 12:00:00 AM	ADDRESS	34.05937	-118.4824	PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: YINGLI YL255P-29b(2) INVERTERS: ABB PV1-3.6-OUTD-S-US-Z-A & PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31860	19041-10000-46963	4561 W PICO BLVD	90019	10	129B185   925	5083031034	C4-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			Corrections Issued	01/06/2020 12:00:00 AM	ADDRESS	34.04881	-118.33505	FULL PLAN CHECK FOR A TI TO AN EXISTING BUILDING. SCOPE INCLUDES NEW 600A 120/240 3PH 4W SERVICE AND NEW EQUIPMENT.TOTAL AFFECTED AREA IS 33796 SQ.FTPer Building permit #: 18016-10001-13073ATTN: JOE VO  SUPPLEMENTAL FOR CHANGE OF USE FROM DANCE STUDIO TO CHURCH  7204 SF  DEMO OF (E) URM BUILDING  6957 SF  AND ADD NEW 8874 SF, 1 STORY OF TYPE V-A  CHURCH REBUILDING. EXISTING PARKING REMAINS. ** PLAN CHECK ONLY **	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31861	17041-20000-28034	14920 W NAVARRE WAY	91342	7	219B149   982	2611046068		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29446	-118.45571	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31862	19041-20001-04245	771-777 N VIRGIL AVE	90029	13	141B197   209	5539017001	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.08536	-118.28701	9/12/19CHANGES TO APPROVED SET DELTA 1 ONLY CHANGES TO TYPE OF LIGHTING FIXTURES.<<<Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement and repartitioning of an existing space to create (3) separate core and shell tenant spaces. Total lighting area = 4,270 sq. ft.Note: Building application has been generated under 18016-10000-33068>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31863	16041-10000-40673	1133 S OLIVE ST	90015	14	126A207    99	5139020021	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.04017	-118.26175	PC FOR T24 ENERGY ONLY. REPLACEMENT OF LIGHTING FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31864	17041-10000-41909	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 175	5161024039	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.05007	-118.2433	PC FOR FIRST TIME TANENT to A gymnasium for new sweat shoppe studio. SCOPE INCLUDES NEW PANELS, CIRCUITS AND LIGHTING.TOTAL EFFECTED AREA  2769 SQ.FTB#17016-10000-31097	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31865	16041-20000-45844	880 N STONE CANYON ROAD	90077	5	144B149   255	4370022025	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM			Plans on Hold	01/10/2017 12:00:00 AM	ADDRESS	34.08988	-118.44679	Plan check for power only. New 2-story SFD w/basement and garage. 800A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31866	18041-10000-40821	1232 N BLINN AVE	90744	15	036B213   601	7425026002	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.78871	-118.24507	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31867	14041-10000-21358	2215 E ALCAZAR ST	90033	14	135A225     6	5202003019	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Apartment			08/14/2014 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.06357	-118.20153	Plan check for power for construction of new 5 story 178 unit dorm at USC. Two 4000 amp services, 3 elevators, 8 sections.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31868	17041-10000-00175	970 W 190TH ST #650	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	33.85812	-118.29302	PC FOR  T.I  IN HIGH RISE BUILDING (6TH FLOOR) SUITE 650.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 5545 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31869	10041-10001-24305	6355 N DE SOTO AVE Bldg  3	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	02/29/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.18639	-118.58869	PERMITTED PLANS WERE REVISED AS FOLLOWING- FEEDERS TO RESIDENTIAL PANELBOARDS WERE CHANGED TO AL FROM CU AND 2EA 10HP TRASH COMPACTORS AND 1 EA 50HP ELEVATOR ADDED TO HOUSE SWBDA new 4 story 128 unit apartment building and area site lighting.  The original plan check submittal fee included some fees for building 2.   A new application was created for building 2, and the building 2 submittal fee was adjusted lower to account for building 2 fees paid on this application number.  The fire alarm plans and permit for building 3 were issued on application # 11041-10000-04061.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31870	19041-20000-53752	6806 S LA TIJERA BLVD	90045	11	102B173   108	4103002025	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	03/18/2020 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	33.97705	-118.37181	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31871	19041-10000-24755	3845 S WISCONSIN ST	90037	8	117B197   756	5037017034	R3-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Issued	06/27/2019 12:00:00 AM	ADDRESS	34.01595	-118.29323	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31872	19041-10000-53209	12800 W WENTWORTH ST	91331	6	198B161   395	2629027068	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			Reviewed by Supervisor	02/19/2020 12:00:00 AM	ADDRESS	34.23659	-118.41161	NEW HYDROPONIC AGRICULTURAL ENTERPRISE. ADDING MORE THAN 400 AMPS OF LOAD TO AN EXISTING 2,000 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31873	14041-10000-34733	8556 S EMERSON AVE UNIT 9	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	01/30/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 9 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31874	19041-30000-42225	6315 W ARIZONA PL	90045	11	105B165   687	4110014015	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM			Corrections Issued	10/17/2019 12:00:00 AM	ADDRESS	33.97977	-118.39661	Energy PC only, Area of scope 3850Sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31875	16041-10000-16572	1150 S OLIVE ST 11TH FLR-LOBBY	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR AN EXISTING OFFICE ON THE 11TH FLOOR OF AN EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS ON THE ELEVATOR LOBBY AND BRIDGE. TOTAL AREA: 2,396 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31876	15041-10000-23964	420 S SAN PEDRO ST 106	90013	14	127-5A213 633	5147005202	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	ADDRESS	34.04498	-118.24321	"PC FOR ENERGY ONLY PER APPLICANT. RESIDENTIAL UNIT. ***PERMIT FEES WERE PAID UNDER EXPRESS #X15LA11730. (((ADD ELECTRICAL CIRCUITS FOR KITCHEN, LAUNDRY AREA, & TWO BATHROOMS. RELOCATE EXISTING LIGHTING FIXTURE BOXES.  ""COMPLY WITH DEPARTMENT ORDER effective date 02/13/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31877	10041-20001-12835	7060 W HOLLYWOOD BLVD Roof	90028	13	147B181   205	5548007016	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			PC Approved	11/30/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	Plan check only. T-24 outdoor energy (general/emergency) lighting on roof deck. Adding Existing permit under #10041-90000-12835	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31878	19041-20000-13869	3028 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	12/21/2021 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31879	14041-10000-09921	2459 E 8TH ST	90021	14	123A217   299	5166006014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.02971	-118.22802	upgrade service to 6ooA; NEW PANEL BOARD AND CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31880	14041-20001-24952	2953 S CLUB DR	90064	5	123B165    37	4316028002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.03713	-118.40054	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 16kW.(1) SunPower SPR-10002f-1 UNI(1) SunPower SPR-6001p-1(56) Sun Power SPR-E20-327 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31881	19041-20001-50978	22955 W MARIANO ST	91367	3	171B097   105	2042008070	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.16843	-118.62733	Expedited plan check fee.PV1.  Install 23.76 kW DC / 21.40 kW AC roof mounted PV system.  (72) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31882	12041-20000-23222	6733 N LANKERSHIM BLVD	91606	2	180B169    52	2322015019	C2-1VL, R1-1, RD1.5-1, [Q]C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.03	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	09/28/2012 12:00:00 AM	ADDRESS	34.19304	-118.38798	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31883	19041-20002-21615	5005 N EDENHURST AVE	90039	13	162B201    20	5593012032	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.142	-118.2736	10-11-2019 Changes to an approved set of plan, changes include relocate PV Modules(540) from PV Carports to roof top of the building, change to (2) 66KW inveter and (1) 100KW inverter. PV system size remins the same.  PERMIT 2 OF 2 - OTHER PERMIT IS ROOFTOP SOLAR UNDER 19041-20000-21601.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31884	17041-10000-01665	10645 N HILLROSE CIR	91040	7	207B189   778	2547010043	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.2627	-118.3253	PC FOR PV SYSTEM USING 11.4KW AC INVERTER AND TOTAL OF 40 MODULES. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31885	14041-20000-04584	12871 N SAN FERNANDO ROAD	91342	7	222B145   268	2604019004	C2-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.30366	-118.46542	4 STORY 18 UNIT APT. Plan check for power and energy. energy for garage. new 1000A 240v 3phase service. building submittal in 2013. plan check in accordance to 2008 NECfire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31886	18041-10000-04372	4201 W WILSHIRE BLVD SUITE 500	90010	4	135B189   972	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.06189	-118.31911	Energy plan check for an office T.I  located in a high rise building. Scope includes new lighting and equipment . Total area is 34245 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31887	17041-10000-12075	9301 N TAMPA AVE 46	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC FOR TI. TITLE 24 ENERGY ONLY. TOTAL  AFFECTED AREA 2473SCOPE INCLUDES NEW LIGHTS AND RECEPTACLESBUUILDING APP # 17016-40000-04679Change of use from Retail to Health Club,TI  and combine two tenant spaces into one.  New restroom and new storefront.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31888	19041-20000-18721	22732 W BERDON ST pv1	91367	3	174B097   722	2040019017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.17087	-118.62233	pv1install roof mounted pv system sized 5.4KW AC interconnetced with msp.(15) ACM rated at 360W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31889	16041-20001-45006	4757 E YORK BLVD	90065	14	156A223   143	5476020024	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	PIN	34.12257919	-118.2116827	Revisions to approved set.  Delta-2 and 3 revisions only.  Changes to architectural details, miscellaneous changes to loads.  (((Plan check for power and energy. Change of use from retail to restaurants + art gallery. Restoring tentant spaces to shell condition. New 800A service. T24: indoor - 435sqft; outdoor - 3,011sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31890	15041-20000-26376	22621 W VENTURA BLVD	91367	3	171B097   167	2040028011	(Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	PIN	34.16779098	-118.6196637	$0 permit fee due to senate bill 1222 from 2012PV2. Install roof mounted PV system sized 100 kW. Interconnected with main service panel.(360) Canadian Solar CS6X-310(1) Solectria PVI 100 kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31891	13041-20002-35618	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.98173	-118.4029	CHANGES TO APPROVED SET. ADDITION OF ELEVATOR, CONDENSING UNIT AND REVISED T24 FORMS. ALL CHANGES CLOUDED DELTA 50 AND 51. PC FOR REVISIONS ONLY. PERMIT TO BE ISSUED FROM THIS APPLICATION FOR ADDITION OF CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31892	14041-10000-29506	1 W WORLD WAY WEST	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	PIN	33.94461393	-118.39808495	Energy plan check for a CBP office T.I. . Total area covers 5735 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31893	13041-10000-28639	1307 S MATEO ST	90021	14	121-5A217  80	5166022034	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.0285	-118.23235	Remove HID light fixtures and replace w/ fluorescent fixtures.  Title 24 plan check only, permit to be issued at EPC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31894	19041-20000-10632	3415 S SEPULVEDA BLVD ste 730	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.02055	-118.42347	ti to an existing commercial building.  plan check for energy indoor energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31895	18041-20000-41185	16253 W LOVETT PL	91436	5	165B137    71	2284015007	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM			Reviewed by Supervisor	11/07/2018 12:00:00 AM	ADDRESS	34.15165	-118.48809	Plan check for a PV1 roof-mounted PV system. System size is 21.05 kWdc/18.78 kWac-CEC and consists of (3) inverters, (69) modules, (3) load centers, and (3) tesla PowerWalls.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31896	14041-10001-10319	814 N CORONADO ST	90026	13	139-5A205 181	5402021011	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1957.10	Electrical	Electrical	Apartment			04/18/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.07699	-118.27037	(((EXPEDITE FEES)))PV2 ROOF MOUNTED TRANSFORMERLESS SYSTEM USING SOLAR EDGE OPTIMIZERS FOR TRIPLEX. TOTAL SYSTEM SIZE 3.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31897	13041-10000-24245	2307 N ECHO PARK AVE	90026	13	145-5A211 218	5443011002	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.09296	-118.24853	INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE AT 4.00KW DC WITH (16) MODULES (250W) IN A 2-STORY HOUSE. TRANSFORMERLESS WITH POWER OPTIMIZERS(OP-250-LV).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31898	18041-10000-10166	18145 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.26469	-118.52687	Plan check for T24 only, Tenant Improvement to existing restaurant.  Install (2) new panels for lightings and power. Total area: 1,881sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31899	17041-20001-37893	9537 N ENCINO AVE	91325	12	201B129   396	2755009047	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.24444	-118.5157	void.........pv1install roof mounted pv system sized 11.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31900	16041-20000-40993	12466 W OSBORNE ST	91331	7	204B165   118	2537004015	R1-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.25706	-118.40524	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31901	16041-20001-24000	19815 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			PC Approved	07/28/2016 12:00:00 AM	ADDRESS	33.85108	-118.28825	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 30 kWac and consists of (1) inverter and (76) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31902	17041-10000-08641	10825 W MOORPARK ST	91602	4	165B173   332	2423007058	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.15053	-118.36664	PC for energy only, outdoor. Removing HID fixutres and replacing them with New LED ones. Area: 30500	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31903	11041-20000-04617	21700 W OXNARD ST 15th Floor	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.17901	-118.60179	T.I. to existing high rise building.  Install general/emergency on 15th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31904	16041-20000-32337	7032 S RAMSGATE PL	90045	11	102B173   397	4103011016	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			09/12/2016 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	33.97338	-118.37312	NEW APARTMENT BUILDING 3 STORY 9 UNIT WITH 800 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31905	15041-20000-25997	4835 N VAN NUYS BLVD Suite 109	91403	4	169-5A151 141	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.1588	-118.44891	Plan check for remodel existing Medical office 3 exam rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31906	19041-30000-14814	718 S HILL ST	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.04527	-118.25477	Fire alarm system for a 7-story commercial building with a basement. Fire alarm consists of (1) FACP and (213) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31907	19041-20000-09452	17617 W TROSA ST	91344	12	219B129    59	2608029002	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.30048	-118.51763	PLAN CHECK FOR PV ROOF MOUNTED SYsTEM FOR EXISTING SFD, SYSTEM SIZE: 8.64KW DC, 7.68 KW AC. SCOPE OF WORK INCLUDES (24) SUNPOWER AC MODULES WITH FACTORY INTEGRATED 320W MICROINVERTERS, AND (2) 100A SOLAR LOAD CENTER PANELS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31908	15041-10000-23073	9815 W NATIONAL BLVD	90034	5	123B165   902	4311003022	C2-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.03155	-118.40025	TI TO AN EXISITING  COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4799.SUBMITTAL PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31909	16041-20000-17304	13784 N DE GARMO AVE	91342	7	228B145   110	2603021027	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Expired	06/19/2018 12:00:00 AM	ADDRESS	34.32241	-118.47141	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW  STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31910	10041-10000-02615	7215 W MANCHESTER AVE	90045	11	096B157   554	4114034027	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Public Safety Only			02/16/2010 12:00:00 AM	02/16/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	33.95998	-118.41998	new fire alarm system in a commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31911	13041-10004-10721	24015 W NORDHOFF ST	91311	12	195B113    79	2781001052	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Expired	12/21/2015 12:00:00 AM	ADDRESS	34.23202	-118.57795	][][CHANGES TO APPROVED SET OF PLANS; ADDING 30 NEW DEVICES TO FIRE ALARM SYSTEM. APPLICATION WILL BE FOR BOTH PLAN CHECK AND PERMIT ][][]Application address of 24015 W Nordhoff was the result of a clerical error that the applicant has taken care of with Addressing Counter but system not updated at time of applicant submittal.  True address is 20415 W Nordhoff.  New fire alarm system for 2-story commercial bldg.  49 devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31912	18041-10000-18490	200 S ALVARADO ST	90057	13	135A205   190	5154020013	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.06373	-118.272	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31913	14041-20000-27136	20519 W CHASE ST	91306	3	192B109   210	2780020003	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.22469	-118.58051	pv standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31914	13041-20001-29844	16167 W ROYAL OAK ROAD	91436	5	162B141   175	2286013008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM			Reviewed by Supervisor	11/05/2013 12:00:00 AM	ADDRESS	34.14143	-118.48363	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 27KW AC. ROOF MOUNTED. TOTAL OF 90 MODULES. USING TRANSFORMERLESS INVrETER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31915	12041-20000-26019	11922 S VERMONT AVE	90044	15	084B197   351	6088020013	C2-1L	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM			PC Approved	11/14/2012 12:00:00 AM	ADDRESS	33.92425	-118.29139	T-24 and emergency lighting plan check for remodeled Ralph's store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31916	19041-20000-28993	555 W 5TH ST 5TH FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	09/17/2020 12:00:00 AM		Permit Finaled	03/08/2021 12:00:00 AM	ADDRESS	34.05016	-118.25369	Power and lighting for TI to (E) commercial highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31917	11041-20000-09883	127 S SAN VICENTE BLVD Delta 45	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			No Progress	06/02/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	Changes from previously approved plans.  All changes indicate by Delta-45 as shown on plans.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31918	13041-10000-08110	17077 W PARTHENIA ST	91325	12	195B133   428	2690010008	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.22866	-118.50523	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 8.82 KW. [INVERTER: SUNNY BOY 7000-US] [SOLAR MODULE: TRINA SOLAR TSM-245 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31919	18041-10000-04006	4619 N CARITINA DR	91356	3	168B117   516	2178020013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM			PC Approved	03/07/2018 12:00:00 AM	ADDRESS	34.15408	-118.5566	INSTALL A NEW 13.8KW PV SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31920	14041-20000-22814	16055 W NAPA ST	91343	12	192B141    29	2673004068	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.22667	-118.48292	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. USING 16 MODULES. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31921	18041-10000-43630	3501 W SUNSET BLVD	90026	13	144A203   188	5429024001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.08906	-118.27633	T-24 ONLY FOR RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31922	14041-20000-32805	11300 W OLYMPIC BLVD suite 900	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM			Ready to Issue	02/02/2015 12:00:00 AM	ADDRESS	34.03792	-118.44134	Plan check for power only. TI to existing office on 9th floor of high rise office building. New receptacles and lighting (incl. emergency). 5,246sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31923	17041-10000-40243	266 S HARVARD BLVD 1ST FL	90004	10	135B193   181	5517019030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.06926	-118.30396	Installing luminires in common corridor and new luminaires outside for the parking lotPLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31924	19041-10000-02167	1100 W MANCHESTER AVE	90044	8	097-5A197 331	6047003008	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	33.95985	-118.29408	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31925	16041-10000-45231	12179 N STEWARTON DR	91326	12	219B121   355	2820017027	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.29349	-118.54471	Install new 10.80 kWdc / 9.60kWac roof-mounted solar array on a single family house.(30) Microinverters modules: SPR-X22-360-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31926	12041-20000-16057	5522 N SEPULVEDA BLVD	91411	2	174B145   598	2250009025	C1.5-1VL, C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.17102	-118.4659	T.I. for medical clinic.  Install new panel, branch circuits, and lighting.  Plan check for power and energy. Urology Specialists of Southern California	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31927	15041-10000-00130	7118 N AMIGO AVE	91335	3	183B121   265	2126006016	(T)(Q)RAS3-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			01/05/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.1999	-118.53846	Pc for power and energy. 3 story, 20 units apartment building.  Total area 14,500 sq. ft. (unconditioned).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31928	15041-10002-06485	722 N VAN NESS AVE	90038	13	141B189   230	5535002004	R3-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.08418	-118.31559	Changes to approved set.  Reduce module count from 60 to 54 and reduce number of inverters from 3 to 2.  New system size = 15.2 kWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31929	17041-10001-36003	5811 S BROADWAY	90003	9	108B201  1346	5101040006	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			Reviewed by Supervisor	10/18/2017 12:00:00 AM	ADDRESS	33.9895	-118.27848	EXPEDITE PER APPLICANT REQUEST.((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP(FEED IN TARIFF). TOTAL SYSTEM SIZE IS 128KWac. (424)MODULES-Q.CELLS Q.PEAK-G4.1 300(2)INVERTERS-YASKAWA PV1 28TL(2)INVERTERS-YASKAWA PVI 36TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31930	14041-10000-20868	409 E LEROY ST	90012	1	135A219   147	5409013913	UI(CA)	Central	Central City North			2060.10	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.06301	-118.22752	"Installation of new rooftop solar PV system on DWP's ""house of the future"" .  6 DC modules plus connected to an inverter and as well as another identical inverter (both are sunverge 4500w solar inverter sis-4548-x).   Total system size = 9 kWac . Contractor is only responsible for design of plans (C-46 981865). DWP is to provide the installation."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31931	10041-10000-23445	6033 W CENTURY BLVD # 400	90045	11	090B169    17	4124030037	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	12/21/2010 12:00:00 AM	ADDRESS	33.94572	-118.38954	TENANT IMPROVEMENTS IN OFFICE SPACESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31932	17041-10001-45037	18318 W SHERMAN WAY	91335	3	183B125   203	2125003017	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.20096	-118.53236	SUPPLEMENTAL PC FOR LOST SET:PC for T24 only for retail space with office spaces. Installing new lights, receptacles and equipment. Total area is 5089sqft. B# 17016-10000-27695.MASTER PERMIT WAS ISSUED UNDER 17041-10000-45037.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31933	13041-10000-21481	2549 N MALLORY ST	90032	14	139-5A233 135	5216009034	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.07638	-118.17766	PV1.  Install 6.540 kW DC roof-mounted solar array, interconnect into upgraded main service panel.  {Transformerless inverter: PVI-6000-OUTD} {20 modules: Sunpower SPR-327NE}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31934	19041-20000-16613	21345 W GERMAIN ST	91311	12	207B105   305	2706029014	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.26319	-118.59673	PLAN CHECK FOR NEW ROOFMOUNTED PV SYSTEM WITH ENERGY STORAGE SYSTEM. SYSTEM SIZE IS 9.6KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (30) SILFAB PV MODULES WITH SE P320 OPTIMIZERS , A SE7600 INVERTER, AND A 9.8KWH LG CHEM BATTERY	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31935	17041-10000-30106	11710 N BALBOA BLVD	91344	12	213B133   166	2610002017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Expired	04/07/2024 12:00:00 AM	ADDRESS	34.28325	-118.50187	PC FOR PV SYSTEM USING 20 MODULES AND CENTRAL INVERTER RATED 5KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31936	10041-20000-24890	1312 E 7TH ST Bldg B1-#37,41,47	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.03615	-118.24064	"Plan check T24 Energy for tenant improvement to interior of storage room (Unit #37, 41, 47) in Building B1. Title 24 only. Existing branch circuits.""COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31937	17041-10000-21809	518 W 111TH PL	90044	8	087A201    49	6075024025	C2-1VL, R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.93369	-118.28327	TItle 24 plan check.  Replace existing fixtures with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31938	16041-10006-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.23567	-118.5584	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER BULLETIN 26. SUMMARY OF REVISIONS HAS BEEN PROVIDED.PLAN CHECK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31939	16041-10000-41383	8900 S EMERSON AVE	90045	11	096B165   960	4122022929	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	33.95564	-118.40413	REMOVE HID FIXUTURE AND REPLACE WITH NEW LED FIXTURE. T24 ONLY. SQFT=54800.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31940	17041-10000-25846	1135 N HIGHLAND AVE	90038	4	144B185   666	5532019019	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.09157	-118.33885	PC for power and energy for office TI. Load is >400A. Building permit 17014-10000-02300. Total area is 27367 sqft. COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 05/19/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.CEIS:769964	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31941	19041-10000-43387	12306 W NAVY ST	90066	11	117B153   613	4248005016	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.01702	-118.44284	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 23 MODULES (POWERXT-360R-PD), 1 CENTRAL INVERTER (SOLAREDGE SE 7600H-US) USING 23 (P370 POWER OPTIMIZERS) TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 8.280KW DC, 7.60KW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31942	14041-10000-06739	1354 S HAUSER BLVD	90019	10	129B177   766	5085032016	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	34.04969	-118.35621	PV1, INSTALL 5.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(22) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31943	13041-10000-04701	810 S SPRING ST #B2	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM			PC Approved	03/15/2013 12:00:00 AM	ADDRESS	34.04268	-118.25375	PLAN CHECK FOR POWER AND ENERGY ON #13041-10000-04706.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31944	14041-10001-18277	6624 S STANFORD AVE BldgC	90001	9	102B205   105	6007017021	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	33.97903	-118.26285	PC FOR CHANGES TO APPROVED SET OF PLANS. REVISE SINGLE LINE DIAGRAM. CHANGE IN AIC RATING AND TRANSFORMER SECONDARY TAP. PLAN CHECKER TO REVIEW NEW LOAD DISTRIBUTION AND CHANGE IN AIC. ALL CHANGES NOTED ON PLANS DELTA 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31945	12041-20000-05058	23391 W MULHOLLAND DR #B	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			PC Approved	03/06/2012 12:00:00 AM	ADDRESS	34.15972	-118.63416	T.I. to existing Nail & Salon space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31946	17041-20001-23727	8250 N LAUREL CANYON BLVD	91605	6	192B165   565	2310001032	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Closed	04/06/2018 12:00:00 AM	ADDRESS	34.22107	-118.39632	3/23/2018changes to an approved set of plans.  changes noted delta 4.  changes to match existing fild conditions.(((Plan check for energy only. TI to restaurant (Taco Bell). New lighting - indoor=1,401sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31947	15041-20000-21541	14006 W RIVERSIDE DR #18	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Tilte 24 only for hair salon. Total indoor area: 1,639 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31948	17041-20001-43971	11569 N BONHAM AVE	91342	7	213B173   184	2530036025	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.28044	-118.37788	expeditepv1install roof mounted pv system sized 8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31949	19041-20000-03136	16830 W VENTURA BLVD #150	91436	5	168B133   253	2289019016	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check for Title 24 only in existing space T.I. Total area: 1,916 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31950	16041-20000-18340	6600 N TOPANGA CANYON BLVD System A	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for PV carport ground mounted system in Topanga Mall Parking Lot. System size:1.2MW with 5,829 modules and 36 inverters(33.3kW) and 3 inverters(20.0kW)This is system A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31951	19041-10000-05759	657 W IMPERIAL HWY	90044	8	087A201   268	6075013029	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	33.93112	-118.28671	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31952	19041-10000-09851	18333 W GAULT ST	91335	3	183B125   364	2125003800	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM			PC Info Complete	01/02/2020 12:00:00 AM	ADDRESS	34.19941	-118.53265	FULL PC FOR POWER AND ENERGY.  SCOPE INCLUDES INSTALLING TWO 1200A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARDS,  AND INSTALLING FOUR NEW DISTRIBUTION BOARDS FEEDING STATE APPROVED MODULUR STRUCTURES. PLAN CHECK ONLY FOR SERVICE, FEEDER,  AND T24 ENERGY. TOTAL AREA IS 18,530 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31953	12041-20000-09683	1609 S WESTWOOD BLVD #A	90024	5	129B153   154	4324026024	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			Reviewed by Supervisor	05/10/2012 12:00:00 AM	ADDRESS	34.05258	-118.43966	CHG OF USE FROM (E) RETAIL TO (N) DENTAL OFFICE. Plan check for power and energy. 1327 conditioned sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31954	14041-20000-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			07/25/2014 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	33.95713	-118.3847	NEW 3000A SERVICE FOR 65 UNIT 4 STORY APARTMENT BUILDING WITH 2 LEVEL UNDERGROUND PARKING.  PLAN CHECK FOR POWER AND ENERGY.*3/24/16: Extension filed. Last date to obtain the permit is on 7/25/16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31955	15041-10000-17862	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2615.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31956	16041-10004-32128	14566 W VENTURA BLVD	91403	4	166-5A151 122	2276001015	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM			PC Approved	10/28/2016 12:00:00 AM	ADDRESS	34.15112	-118.45096	changes to approved set. change to emergency fixtures. checking new photometric detail. pc only. permit already under master app.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31957	10041-10000-00102	1137 S COCHRAN AVE	90019	10	132B181  1090	5085011013	R3-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM	01/07/2010 12:00:00 AM		Permit Finaled	05/25/2010 12:00:00 AM	ADDRESS	34.05472	-118.35024	Plan check 2008 T-24 energy for new Recreation room  addition.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31958	18041-30000-43274	3780 N CAHUENGA BLVD	91604	4	162B177   407	2425001060	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	06/24/2020 12:00:00 AM		Permit Finaled	01/20/2021 12:00:00 AM	ADDRESS	34.13712	-118.36296	Full plan check for power and energy. Scope includes swapping one gasoline dispenser for one hydrogen dispenser and adding one hydrogen fuel dispenser with supporting hydrogen equipment to an existing gas station,. Total area: 355 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31959	16041-10000-22632	1536 N BLUE JAY WAY	90069	4	147B169   285	5561011015	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.10043	-118.38698	PC FOR POWEER. New single-family dwelling with private garage. 600A SERVICE.B# 14010-10000-02001PLANS SHOULD BE SIGNED BY THE ENGINEER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31960	17041-20001-17094	1812 S ROXBURY DR	90035	5	129B165   711	4307013027	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.04821	-118.40115	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 19 kWac and consists of (55) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31961	19041-10000-52831	4200 W PICO BLVD	90019	10	129B185  1101	5082023002	C4-2D-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	11/20/2020 12:00:00 AM		Permit Finaled	10/11/2022 12:00:00 AM	ADDRESS	34.0476	-118.32711	SCOPE OF WORK INCLUDES NEW SERVICE, 120/208V, 1200 AMP, 3PH, MAIN SWITCH BOARD SUB FEEDS TENANT PANELS, MBA AND MBB. NEW LIGHTING AND CIRCUITS, TOTAL INDOOR SQ. FT. 16423 AND OUTDOOR SQ. FT. 696. ******************************************5 story new construction of 54-units of permanent supportive housing for seniors that will have common areas, and 2500 SF of at grade commercial space.  The common area services includes on site property management office, community room, community laundry facilities, and outdoor hardscaped and landscaped courtyards.   The building is a five (5) stories Type IIIA construction (4-stories wood construction over 1-story concrete podium).  There will be a total of (53) studios and (1) two-bedroom manger's unit.  3 required parking provided for commercial offices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31962	16041-20000-21492	8720 S MENLO AVE	90044	8	096A199    85	6038022021	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	33.95825	-118.29029	Plan check for PV roof monted system. System size: 2.3kW with 9 modules and 9 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31963	13041-10000-14061	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	07/02/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	13041-10000-14061T.I. to existing building (Hyperion).  Install general/emergency lighting.  Plan check for energy only.Note: Per applicant, the building is low rise with optional standby generator.  To be verified by field inspector.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31964	13041-10000-27247	9900 N GLENOAKS BLVD	91352	6	201B169    37	2528010022	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.24994	-118.38739	Remove HID light fixtures and install new fluorescent fixtures.  Title 24 ENERGY plan check only. 3150 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31965	13041-20000-26861	2200 N SICHEL ST	90031	1	138A223   415	5204019023	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07035	-118.21288	PC FOR POWER AND ENERGY FOR EXISTING CHURCH. NEW ELECTRICAL AND NEW 600A SERVICE. PLACE OF ASSEMBLY. FUTURE AC PANEL. AND FUTURE TOWER LIGHTING CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31966	13041-20001-12549	14006 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	((CHANGES MADE TO APPROVED SET OF PLANS. CHANGED OUT MOST OF THE LIGHTS, RECHECKING T24))Change of use from retail to beauty salon.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31967	13041-10001-17839	23015 W RUNNYMEDE ST	91307	12	186B097   624	2021006003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	34.2051	-118.62839	Change of approved set from Power One Aurora PVI-4.2-OUTD-US to PVI-5.0-OUTD-US.  (((PV1.  Install 5.75 kW DC roof-mounted PV array, interconnect into main service panel.  {23 modules: Trina Solar TSM-250PA05.08} {Transformerless inveter: Power One Aurora PVI-4.2 OUTD-US})))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31968	13041-10001-29814	11233 N SAN FERNANDO ROAD	91331	7	210B157   166	2616030063	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.2739	-118.43067	Install (2) new 1999 GAL PROPANE TANK above ground in LAUSD bus parking lot. located in methane zone. area is class I div II classification for entire space within dispenser enclosure. (2) 50A-3Pole fuel pumps on an existing 200A service with a new 60 Amp panel. All Electrical Equipment shall be Listed by UL for Class I Div II.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31969	13041-20001-23758	7800 N CAPISTRANO AVE	91304	12	189B101   673	2013012020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.21208	-118.61652	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 24 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 3 STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31970	19041-10000-39380	9800 S LAUREL ST	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	33.94799	-118.23082	pc for new fire alarm system in a commercial building. (1) facp and (93) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31971	17041-20002-25745	15206 W PARTHENIA ST	91343	6	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.2281	-118.46381	11/8/17  CHANGES TO APPROVED PLANS. PLANCHECK ONLY. ADDING (2) ADDITIONAL RAPID SHUTDOWNS TO MEET FUSE REQUIREMENT FOR 3 OR MORE STRINGS ON DC SIDE OF INVERTERS]]]]]pv2install roof mounted pv system sized 55kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31972	18041-30000-11399	350 S GRAND AVE #3000	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only in existing high-rise building office T.I.. Total area: 11,940 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31973	18041-10000-39941	5849 S CROCKER ST Bldg K	90003	9	108B205  1217	6006029001	[Q]MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.98846	-118.26863	"REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY IN BUILDING ""K""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31974	19041-10000-00460	505 N MARINE AVE 1-17	90744	15	030B205  1040	7418004009	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	08/27/2021 12:00:00 AM	ADDRESS	33.7759	-118.2636	FULL PLAN CHECK FOR A NEW 2 STORY 17 UNIT LOW INCOME APARTMENT BUILDING, 100% AFFORDABLE HOUSING PROJECT. SCOPE INCLUDE 800-AMP 120/240V 3-PHASE 4-WIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31975	19041-20000-50258	5300 W MELROSE AVE	90038	4	141B189   384	5522001007	(Q)M1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM			Reviewed by Supervisor	01/09/2020 12:00:00 AM	ADDRESS	34.08336	-118.31616	PV3. Install 638.04 kW DC roof mounted PV system.  (1636) modules with (5) 100 kW and (1) 66 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
31976	17041-20000-36298	9841 N AIRPORT BLVD 11th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  11th floor corridor and bathrooms only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31977	13041-10000-22058	6066 W OLYMPIC BLVD	90019	10	132B177   667	5086001066	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	PIN	34.05785658	-118.363636	pc for energy only. permit to be pulled at EPC counter only.Non-structural interior tenant improvement to existing retail/restaurant space.  No change of use, no change to emergency lighting. starbucks.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31978	13041-10000-10857	432 E TEMPLE ST	90012	9	130-5A215 298	5173008906	M3-1	Central	Central City North	Historic Cultural		2060.30	Electrical	Electrical	Commercial			04/26/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.05043	-118.23692	INSTALLATION OF NEW FIRE MONITORING SYSTEM . IN METRO CONNECT SERVICE BUILDING. PC FOR NEW FACP AND A COUPLE NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31979	18041-10000-46406	12050 W VENTURA BLVD STE B105	91604	2	162B165   141	2369015019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	Yes	1438.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.14349	-118.39426	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31980	15041-10000-07184	15350 W SHERMAN WAY Suite  250	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.20099	-118.46808	Energy plan check for office T.I , Scope includes new lighting,  new circuit and new control ;total area is 7377-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31981	12041-20000-20720	707 W WILSHIRE BLVD 35th floor	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM			PC Approved	08/31/2012 12:00:00 AM	ADDRESS	34.04893	-118.2572	T-24 and emergency lighting plan check for a portion of the 35th floor.  (#3500)  REMODEL OF EXISTING TENANT SPACE, DEMOLITION OF EXISTING CONSTRUCTION & FINISHES, CONSTRUCTION OF NEW ONE HOUR FIRE RATED EXIT CORRIDOR;  NON -BEARING PARTTIONS, NEW ACOUSTICAL CEILING SYSTEM  **** SEE APPLICATION COMMENTS FOR REST OF JOB DESCRIPTION***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31982	13041-10000-24425	5007 N COLLEGE VIEW AVE	90041	14	162A221   176	5682023002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.13811	-118.21964	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 4.655KW DC IN A TWO-STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS,UNGROUNDED SYSTEM WITH POWER OPTIMIZERS.(19) MODULES: TRINA SOLAR #TSM-245PC05/PA05.18(1) INVERTERS:SOLAREDGE #SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31983	15041-20000-18380	7741 N BECK AVE	91605	6	189B169   817	2316003004	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.21155	-118.38361	PV1 SFD. TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER SYSTEM. USING TOTAL OF 16 MODULES. NONSTANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31984	10041-10000-22563	732 E 10TH ST # 106	90021	9	124-5A211 195	5132011030	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.03504	-118.25099	First tenant in retail space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31985	19041-10000-18532	106 E OLYMPIC BLVD	90015	14	126A209   111	5139015040	[Q]C5-2D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.04004	-118.25667	NEW FIRE ALARM SYSTEN IN A 8 STORY PARKING STRUCTURE (6 ABOVE & 2 BELOW GRADE) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31986	19041-10000-01720	6760 W HOLLYWOOD BLVD	90028	13	148-5A185 151	5547012005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.10139	-118.33787	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR TENANT IMPROVEMENT FOR A 1,938SF RESTAURANT WITHIN AN (E) BUILDING. LOAD UNDER 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31987	14041-10000-09978	622 N RAMPART BLVD	90026	13	139-5A205 286	5402010017	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.07609	-118.27221	PV1 Roof mounted transformerless standard plan.  Total system size = 3 kW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31988	16041-10000-07571	21221 W OXNARD ST	91367	3	177B105    59	2149005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Apartment			03/03/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.17943	-118.59525	NEW FIRE ALARM SYSTEM FOR A 6 STORY 379 UNIT APARTMENT WITH GARAGE (INCLUDES 101 JOINT LIVE/WORK UNITS. SCOPE INCLUDES 1 FA PANEL, 1857 FA DEVICES, AND 1 COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31989	18041-10000-40351	8734 S BELLANCA AVE	90045	11	096B169   844	4125018007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	33.95765	-118.38038	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31990	15041-10004-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED AS DELTA 13-15 ON PLANS. CHANGES TO  MINOR PANEL SCHEDULE REVISIONS MINOR LIGHTING CHANGES. CHECKING FOR UPDATED PANEL SCHEDULES.Total 9 added circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31991	15041-20000-29972	3470 S TROUSDALE PKWY	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.02202	-118.28393	PLANCHECK FOR POWER. REPLACING 1 CHILLER AND 4 PUMPS AT USC WATER PHILLIPS HALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31992	16041-20000-28313	21800 W OXNARD ST 5TH FLOOR-BATHROOM	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.17898	-118.60253	PLAN CHECK FOR ENERGY ONLY. FIFTH FLOOR BATHROOM REMODEL. NEW LIGHTING (INCLUDING EMERGENCY). 514 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31993	18041-10000-09343	4236 N WHISPERING PINES CT	91316	5	165B125   260	2184040007	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.1478	-118.52961	PC for 9.6kW(ac) PV solar system for SFD. Installing 30 AC modules (10.35kW(dc)) , 125A load center and downsizing main breaker to 175A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31994	19041-10000-30326	4618 N DEGOVIA AVE	91364	3	168B097   585	2074034021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.1551	-118.62899	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.52KWdc / 11.4KWac. (32)MODULES- SOLARIA POWERXT 360R-PD(32)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE 11400H-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
31995	18041-20000-21502	11135 W HORTENSE ST	91602	4	168B173   850	2353033039	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Re-Activate Permit	11/07/2019 12:00:00 AM	ADDRESS	34.15462	-118.37366	Plan check for PV roof mounted system. System size: 11.4kW with 44 modules and 1 inverter(11.4kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
31996	15041-10000-43276	17383 W SUNSET BLVD A360	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, TI TO AN OFFICE SPACE ON THE 3RD FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING ON THE OPEN OFFICES. WORK INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL SQ. FT. 1630.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31997	17041-10002-13666	3643 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.02019	-118.3559	Changes to approved set.  All changes clouded with delta 1.  Addition of daylight sensors and relocation of subpanel.            Building permit #16016-30000-24375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
31998	18041-20001-02199	22160 W VENTURA BLVD	91364	3	171B101   122	2169001044	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.16836	-118.61018	Revisions to approved set.  SLD revisions, recircuiting of branch circuit homeruns, lighting and power plan layout changes throughout. Changes apply to delta 1 only.  Plan check only. (((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. BUILDING PERMIT # 17016-10000-29864)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
31999	13041-10000-33897	777 E 12TH ST STE 1-22	90021	14	123A211    59	5132010036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.03264	-118.25093	TITLE 24 PART 6 ENERGY LIGHTING WORK FOR 621 SQ FT AREA. REMOVING (E) HID LIGHT FIXTURE AND REPLACING WITH NEW FLOURESCENT FIXTURES.  REPLACING TOTAL (3) UNITS ON EXISTING CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32000	16041-10001-05078	11300 W NATIONAL BLVD	90066		120B157  1125	4250026022							Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM			PC Approved	03/22/2016 12:00:00 AM	ADDRESS	34.02602	-118.43153	Changes to approved set to a mcDonalds restaurant. Note changes under delta 2. Adding new indoor lighting and modifying outdoor lighting. Total Sq ft = 1787	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32001	19041-20000-08220	9175 N DEERING AVE	91311	12	198B105   137	2746010028	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM			Reviewed by Supervisor	04/09/2019 12:00:00 AM	ADDRESS	34.23756	-118.59629	Plan check for power for change of use from industrial/office to Hydroponic Agricultural Enterprise/Manufacturing with 1600A Service.B#18016-20000-28250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32002	16041-20000-13688	350 S HILL ST	90013	14	130-5A211 149	5149015024	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			PC Info Complete	06/09/2016 12:00:00 AM	ADDRESS	34.05047	-118.24998	PLANCHECK FOR POWER AND ENERGY FOR NEW MIXED USE HIGH RISE BUILDING.  BUILDING PERMIT #  14010-10000-04182 :PERMIT FOR A  31-STORY, TYPE IA MIXED USE BUILDING (428 UNIT APARTMENT, GARAGE AND RETAIL).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32003	17041-10000-30475	11129 W VANOWEN ST	91605	2	183B173   182	2319005017	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.19409	-118.37341	TITLE 24 PLAN CHECK TO REMOVE EXISTING (7) HID FIXTURES AND REPLACE WITH LED FIXTURES. 13125 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32004	16041-10002-23137	9235 N SOPHIA AVE	91343	12	198B137   629	2676024020	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.23849	-118.48849	08/04/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REUSING EXISTING SPLIT 100A/100A MAIN SERVICE PANEL, AND REMOVING COMBINER BOX FROM SINGLE LINE DIAGRAM.NOTE: PERMIT IS PULLED UNDER PCIS# 16041-10000-23137(((((PV1. INSTALLING  6.5KW DC ROOFTOP MOUNTED SOLAR ARRAY ON A SINGLE FAMILY. 25 MODULES  HUUNDAI HIS-S260RG (260W) INCLUDINGMICROINVERTES ENPHASE M215-60-2LL-S22 and COMBINER BOX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32005	18041-20000-46973	13403 N ANDALUSIA LANE	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.31486	-118.42247	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) micro-inverters and (7) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32006	11041-20000-25870	100 S THE GROVE DR IT Room in-Garage	90036	4	138B177  1156	5512004907	OS-1XL-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM			PC Approved	12/05/2011 12:00:00 AM	ADDRESS	34.0746	-118.35615	T-24 lighting plan check for new IT equipment room created in the garage area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32007	14041-20000-09502	20956 W VENTURA BLVD # 3	91364	3	171B109    87	2167024046	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.16638	-118.59024	CHANGE OF USE FROM CIGAR SHOP TO BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32008	13041-10000-11408	1520 N WILCOX AVE	90028	13	147A187    68	5546013030	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	05/02/2013 12:00:00 AM	ADDRESS	34.09871	-118.33087	PC FOR ENERGY ONLY. LESS THAN 400A PER APPLICANT. TI TO EXISTING JAGUAR service center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32009	15041-10000-32680	711 S HOPE ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Expired	10/30/2017 12:00:00 AM	ADDRESS	34.04757	-118.25858	New fire alarm system for a existing hotel tower at the bloc core and shell for renovations on street level through third, and additional devices on 25th and roof levels.  Existing devices with 52 new FA devices.Original plan check submittal fees paid under 14041-10000-34657.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32010	19041-20001-36895	23251 W MULHOLLAND DR	91364	3	168B093   229	2074039031	(Q)CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.15499	-118.63293	EXPEDITED PER CUSTOMER REQUEST.PV2. INSTALL 203.19 KW DC ROOFMOUNTED SOLAR SYSTEM WITH (521) HANWHA Q-CELL MODULES AND OPTIMIZERS. SCOPE OF WORK INCLUDES (2) SOLAR EDGE SE100KUS INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32011	17041-10002-01258	8151 N VENTURA CANYON AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.21934	-118.42889	PC FOR CHANGE OF M.V. FEEDER SIZE PER RFI. UNDER DELTA 8.SCOPE INCLUDE SIZE CHANGED TO 250 KCMILTHIS IS PLAN CHECK ONLY. CHNGING Plan check for power only, new Fuel Cell system rated at 1.6 MW. Fuel cell system is rated at 480 V conncected to 4.16KV (Medium Voltage) distribuition system OSHPD.  Installation on Keiser building connected exterior to OSHPD  4160 V medium voltage service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32012	13041-10000-02446	3921 N EAGLE ROCK BLVD 1-9	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Apartment			02/20/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.11962	-118.23051	New building C with 9 units.  Install new 600A service, new switchboard, subpanels, and branch circuits.  Plan check for power only.  Note: Electrical Permit shall be issued after the Building Plans are approved.  A variance shall be file to separate fire alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32013	15041-20000-09948	12048 W RYNGLER ROAD	91604	2	162B165   694	2369019028	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.13966	-118.39349	pv1. addition to an existing system. system total size; 9kw	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32014	17041-10000-35867	6500 W WILSHIRE BLVD 20 floor	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.06371	-118.3703	FULL PC FOR TENANT IMPROVEMENT FOR 20TH FLOOR, NEW LIGHTING AND POWER DISTRIBUTION, NOT INCLUDING REPLACEMENT OF POWER DISTRIBUTION EQUIPMENT.  EXCEEDS 200A NEW LOADS, ~19,000 SQ FT T24 USING PERFORMANCE METHODB# 17016-10000-28710	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32015	10041-10000-04292	7919 W SUNSET BLVD	90046	5	147B177   994	5551018008	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM	03/15/2010 12:00:00 AM		Permit Closed	04/06/2010 12:00:00 AM	ADDRESS	34.09821	-118.36239	INSTALLING LED LUMINAIRES FOR PATIO OUTSIDE DINING AT A RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32016	14041-10000-17190	540 S KINGSLEY DR	90020	10	135B193   794	5503024004	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			06/26/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.06422	-118.30266	Plan check for power and lighting. New 35 unit apartment building. New electrical service, new diesel generator,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32017	16041-10005-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	34.0365	-118.3687	Supplemental for lighting changes in Area A . Check T24 forms and altered lighting. All changes clouded under delta 18.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32018	12041-20000-12058	431 W 7TH ST	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.04654	-118.25516	T.I. to existing building.  Install general/emergency lighting in restroom and corridor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32019	17041-20000-01328	3715 S MCCLINTOCK AVE 2&3 flr	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.02041	-118.29027	ti to an existing commercial buillding(bathrooms in the 2nd and 3rd flr).  adding new lighting new controls to existing panels.  total square footage 947.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32020	19041-10001-49596	10403 W VALLEY SPRING LANE	91602	4	165B177   796	2424015018	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM			PC Approved	01/16/2020 12:00:00 AM	ADDRESS	34.14687	-118.35734	EXPEDITE PER APPLICANT REQUEST. PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.0696KWdc / 14.106KWac.(48)MODULES-327 W MODULES(48)MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32021	14041-20000-15798	17329 W RAYEN ST	91325	12	195B129   212	2768018004	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/20/2014 12:00:00 AM	ADDRESS	34.2323	-118.51236	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11KW AC USING 2 CENTRAL INVERTERS. NONSTANDARD PLAN. TRANSFORMERLESS INVERTERS.FEE IS $0.00 DUE TO STATE SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32022	17041-20000-07893	13718 W VENTURA BLVD	91423	4	165B157   669	2266020005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.14796	-118.43185	ti to an existing restaurant.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 1540.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32023	19041-10000-12417	1168 S LA BREA AVE	90019	10	132B181  1202	5084021015	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	08/17/2020 12:00:00 AM		Permit Finaled	08/18/2020 12:00:00 AM	ADDRESS	34.05413	-118.34323	PC FOR POWER AND ENERGY FOR NEW STRUCTURE (STORAGE / WAREHOUSE FOR ART GALLERY)SCOPE INCLUDES NEW PANEL, LIGHTS, CIRCUITS AND EQUIPMENT. POWER SERVED FROM OTHER BUILDING. TOTAL AFFECTED AREA 2080 SQ. FT. B#19010-20000-00532	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32024	15041-10001-01526	6875 S HOOVER ST	90044	8	102B197   586	6013008029	C2-1VL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	33.97745	-118.28727	Expedited per applicant request.installation of roof-mounted solar array, interconnect with main panel. System size: 3.315kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32025	10041-20000-20792	11541 N BLUCHER ST bldg3	91344	12	213B145    79	2605002012	QC1-1VL, QP-1VL	North Valley	Granada Hills - Knollwood		YES	1092.00	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	PIN	34.27943684	-118.47043731	Permit expired (BLDG. 3).  EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32026	17041-10000-40933	17751 W SABBIADORO WAY	90272	11	126B117    52	4416014044	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.04465	-118.56155	PC FOR INSTALLING ESS. SCOPE INCLUDES SINGLE POWERWALL WITH AN ADDITIONAL NEW LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32027	14041-10000-01509	5128 N BLUEBELL AVE	91607	2	171B161   692	2357002010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			Verifications in Progress	05/21/2014 12:00:00 AM	ADDRESS	34.16372	-118.41036	PV1, Install 12.5 kW DC roof-mounted solar array for a  two story house, interconnect with main service panel. Negatively grounded system. (1) Transformered inverters: Fronius IG PLUS V 10.0 (50) Modules: SOLAR TSM-250P A05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32028	17041-10001-19188	7061 W FOOTHILL BLVD PV	91042	7	202-5A201 456	2568016050	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			Reviewed by Supervisor	06/23/2017 12:00:00 AM	ADDRESS	34.24814	-118.28543	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32029	10041-10000-23825	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	34.02224	-118.28008	alterations in hallway and storage area on the first floorplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32030	17041-20000-16746	829 N CROFT AVE	90069	5	141B173   100	5529003127	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			05/18/2017 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	06/15/2021 12:00:00 AM	ADDRESS	34.08612	-118.37445	Plan check for power and energy. Project site is a 4-story, 15-unit apartment building with 1 level of subterranean parking garage. Total lighting area = 20,315 sq. ft.Note: Building permit has been issued under 14010-30000-03159	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32031	13041-10000-12313	788 S CENTRAL AVE	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/13/2013 12:00:00 AM			PC Approved	05/13/2013 12:00:00 AM	ADDRESS	34.03414	-118.24273	ALTERATION OF COMMERCIAL COOLERS FOR A PRODUCE MARKET.PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32032	19041-10000-23244	116 S AVENUE 56	90042	1	151-5A229 388	5468025900	PF-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.10847	-118.19372	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32033	15041-20002-28632	11062 N WINNETKA AVE	91311	12	210B113    69	2708021009	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM			PC Approved	11/03/2015 12:00:00 AM	ADDRESS	34.27121	-118.56932	11/03/2015 Changes to an approved set of plans. Changes include the removal of DC disconnects from the combiner boxes, some wire sizes, and the change of the location of (1) of the inverters. All changes have been clouded.*****Previous Work Description*****Installation of new roof mounted solar PV array.  Total system size = 34.2 kWac.  System consists of 160 Solar World 250 W modules divided into 8 strings connected to 3 Solar Edge SE 11400A inverters.  Existing 600 A MSP to have main breaker derated to 500 A.Note: $0.00 permit fees due to Senate Bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32034	11041-20000-14452	19216 SINGING HILLS DR	91326	12	213B117   339	2822012028	A1-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Finaled	08/29/2011 12:00:00 AM	PIN	34.27645714	-118.55500118	PLAN CHECK 24 ENERGY FOR NEW BAR/FOOD PREP AREA TI TO (E) DINNING RM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32035	16041-10000-10100	755 S SPRING ST	90014	14	127-5A211 157	5144015018	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Closed	08/30/2018 12:00:00 AM	ADDRESS	34.04336	-118.25369	PC FOR POWER ONLY, TEMPORARY POWER FOR A CONSTRUCTION SITE. SCOPE INCLUDES TWO 800A, 480Y/277, 3PH 4WIRE SERVICES, TWO 800A MAIN DISTRIBUTION BOARDS, FOUR NEW TEMPORARY PANELS, AND NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32036	11041-10000-06317	7040 N SEPULVEDA BLVD	91405	6	183B145  1121	2220022010	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			Corrections Issued	04/11/2011 12:00:00 AM	ADDRESS	34.19889	-118.46596	T.I.  SINGLE STORY REMODEL FOR BANK.  PLAN CHECK FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32037	14041-20000-24960	11240 N TAMPA AVE	91326	12	210B117    29	2822019004	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.27425	-118.55621	New gas station with conveniance store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32038	18041-20000-37736	5200 W WILSHIRE BLVD unit r2	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.06194	-118.3435	first time tenant.  plan check for power and energy.building application number 18016-20000-32059	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32039	16041-10000-09488	10309 W OLYMPIC BLVD	90064	5	129B161    58	4319005072	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM			PC Info Complete	03/17/2016 12:00:00 AM	ADDRESS	34.05271	-118.41729	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (RALPH'S MARKET #156). SCOPE INCLUDES NEW DECOR LIGHTING AND REPLACE EXISTING DECOR LIGHTING. TOTAL AFFECTED AREA IS 1747 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32040	14041-20000-09925	17500 W BURBANK BLVD	91316	5	174B129   855	2254037019	RA-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.17213	-118.51506	PV2.  Install 92.2 kW roof-mounted PV system on commercial property (church).  Both transformer-ed and transformer-less inverters.  (318) modules.($0 permit feee due to senaste bill 1222 from 2012)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32041	12041-10000-09019	1311 N SAN FERNANDO ROAD BLDG C	90065	1	150B213  3619	5442002908	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.09591	-118.23223	Plan check for a new 165-unit apartment bldg.Application for deferred approval of fire alarm system NOT submitted.(Taylor Yard Apartment (Building C) - construct new 16 low restricted affordable-unit apartment with parking option II - 100% PDPP)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32042	11041-10000-24522	800 E 6TH ST	90021	14	126A213   161	5147029035	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM			Reviewed by Supervisor	12/01/2011 12:00:00 AM	ADDRESS	34.04054	-118.24279	New restaurant in existing building.  Change of use from bank to restaurant per applicant.  Relocate 3 panels, and add new circuits.  Full plan check. New plan check #12041-10000-03659	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32043	15041-20000-19368	635 W DOWNEY WAY 4TH FL.	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.01874	-118.28387	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. 4TH FLOOR  OF THE USC - VPD BUILDING. approved core and shell included- elie approved	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32044	16041-10000-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	34.23567	-118.5584	PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE  APARTMENT WITH 215UNITS.   AND RESTAURANT/ RETAIL CORE & SHELL.  FOUR FLOORS OF RESIDENTIAL OVER TWO FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL. THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMP, 4000 AMP, AND 1600 AMP.  TOTAL AREA = 408,828 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32045	17041-30000-10751	4505 S GLENCOE AVE 1st-2nd floor	90292	11	105B153    96	4212007009	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.98462	-118.43495	PC FOR TI- 24 FOR EXISTING OFFICE BUILDING. TOTAL AFFECTED AREA OF 1076 SQ.FT SCOPE INCLUDES NEW LIGHTS AND NEW RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32046	16041-20000-09619	1715 S ORCHARD AVE	90006	1	126B197   336	5056019036	R3-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	04/09/2016 12:00:00 AM	ADDRESS	34.04282	-118.28878	Plan check for a PV1 roof-mounted PV system. System size is 2.3 kWac and consists of (9) micro-inverters and (9) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32047	12041-10001-15931	3941 E GOODWIN AVE	90039	4	162B205   173	5593020012	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.13718	-118.27187	Revision to the approve plan. EPC is for delta 17 only. Change the size of 4 breakers and feeders. ((((((((((((((((((((((((((CONSTRUCTION OF A NEW 5452 SQ FT TIME WARNER CABLE UNMANNED CABLE HEADEND FACILITY TO CONSIST OF THE FOLLOWING: HEADEND ROOM, DC POWER ROOM, ELECTRICAL ROOM, LOBBY/QUIET ROOM, STORAGE ROOM AND ACCESSIBLE UNISEX TOILET <SEE COMMENT)))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32048	13041-10000-32358	6600 N TOPANGA CANYON BLVD SPACE 93	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	RE- PLAN CHECK DUE TO LOST PLANS. TITLE 24 ENERGY PLAN CHECK ONLY. MALL . 2 FLOORS. WORK ON SPACE #93. EMERGENCY LIGHTING. 2187 SQFT. PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32049	18041-10000-27036	8520 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	07/15/2021 12:00:00 AM	ADDRESS	34.22539	-118.50158	PV2. CARPORT. FEED IN TARRIF. GROUND MOUNTED SYSTEM FOR 8520 BALBOA ONLY. 765.2 KW AC, (23) SOLAREDGE SE33.3KUS, (2484) LG395 MODULESPERMIT FEE IS 0 $ DUE TO ASSEMBLY BILL 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32050	15041-10000-23464	11985 W BLUFF CREEK DR WORKSPCE	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.98221	-118.40251	FULL PC, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER IN THE WORKSPACE. LOADS FOR THE CAFETERIA IS NOT PART OF THIS SUBMITTAL AND IS COVERED UNDER APP#: 15041-10000-23464   TOTAL SQ. FT. 25417. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32051	19041-20000-25719	3801 S BROADWAY	90037	9	117A203   215	5122038022	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Issued	07/05/2019 12:00:00 AM	ADDRESS	34.01402	-118.27726	T24 PLAN CHECK FOR LIGHTS AND OUTLETS FOR A EXISTING SCHOOL BUILDING. TOTAL SQUARE FOOTAGE = 1,939 SFPARTIALLY PAID FOR UNDER PERMIT# 19041-90000-20786	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32052	16041-20000-09970	2733 W AVENUE 31	90065	1	153A213   205	5457012005	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.11145	-118.2408	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (10) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32053	10041-20001-18168	7250 W FRANKLIN AVE 1st floor	90046	4	147B181    21	5548025***	R3-1	Central	Hollywood	Hollywood Hills West	YES	1899.03	Electrical	Electrical	Apartment			08/18/2011 12:00:00 AM			PC Approved	08/18/2011 12:00:00 AM	ADDRESS	34.10329	-118.34724	Plan check for revision to approved plans. Revision to T24 calculations and fixture layout are clouded on plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32054	18041-20000-42228	9438 N BIANCA AVE	91325	12	198B129    51	2766016003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.24249	-118.514	Plan check for PV roof mounted system, system size: 14.3kW with 44 modules and 1 inverter(11.4kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32055	15041-10000-01606	5933 W CENTURY BLVD ste A	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Issued	01/23/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	Energy plan check for a coffe shop ( Starbucks ) T.I with new  transformer and panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32056	11041-10000-17338	11666 W BURBANK BLVD	91601						NORTH HOLLYWOOD-VALLEY VILLAGE				Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	34.17194	-118.38684	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32057	10041-10000-14837	12115 W OHIO AVE	90025	11	126B145   759	4263037020	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.04005	-118.46335	"CHANGE OF USE FROM THEATRE [C OF O, 89WL84925] TO RESTAURANTS.  (2) TENANT, CREATE A DEMISING WALL].  TI ON 1ST TENANT ""IHOP"".  TI AT 2ND TENANT UNDER SEPARATE PERMIT.  CONVERT ENTIRE 2ND FLOOR TO MECHANICAL ROOM.  NO CHANGE IN PARKING.(((((((((((((((((( ELECTRICAL PLANCH FOR POWER, LIGHTING AND ENERGY TITLE 24.)))))))))))))))))))))))))))))))))))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32058	12041-10000-03429	175 S FAIRFAX AVE	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			Corrections Issued	03/04/2013 12:00:00 AM	PIN	34.07185666	-118.36174302	"New fire alarm system for a new retail building (shell only) with one control panel and 27 devices.  Permit under ""Inspection"" for 18 fire alarm devices.  Permit for other devices is under 11041-10000-25812"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32059	14041-10000-19539	5539 W MANCHESTER AVE	90045	11	096B173   109	4127024029	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	33.96007	-118.37778	INTERIOR TENANT IMPROVEMENT/REMODEL OF AN EXISTING YOSHINOYA REST. INTO A WABA GRILL FAST FOOD.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32060	13041-20000-33400	200 N AVENUE 64	90042	14	154-5A233 385	5493016013	[Q]C4-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM			Corrections Issued	12/02/2013 12:00:00 AM	ADDRESS	34.11564	-118.18062	PV2 COMMERCIAL PV. USING MICROINVERTER ENPHASE M215. NONSTANDARD PLAN. 2 PANELS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32061	14041-20000-12013	12747 1/2 W VENTURA BLVD	91604	2	165B161   936	2375021022	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	PIN	34.14554654	-118.41128785	TI to (E) retail space for ice cream parlor.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32062	18041-10000-23444	9855 N MASON AVE	91311	12	201B109   130	2748005044	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.2493	-118.58012	Full plan check for a new restaurant (Jack in the Box). Scope includes a new service of 600Amp, 4-subpanels, new circuits and lighting with a total Title-24 area cover 1,860-SQ FT + 61,343 sq.ft outdoorB# 18010-10000-03208	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32063	14041-20000-25792	12324 W VENTURA BLVD	91604	2	162B165   254	2369002025	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.14284	-118.40161	Plan check for energy only. TI to existing beauty salon. New lights, incl. emergency. 1872sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32064	13041-20001-19313	1136 S PLYMOUTH BLVD PV-1	90019	10	129B185   407	5082017008	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.05169	-118.32866	Changes to approved set of plans. Reduction of service size to 125A and 100A main OCPD.New 6.0kw Roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED and uses Enphase Microinverters. 200A service upgrade has been included in permit fee.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32065	18041-10000-34312	1043 S ABBOT KINNEY BLVD	90291	11	108B145   979	4239021019	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	05/09/2022 12:00:00 AM		Permit Finaled	10/24/2022 12:00:00 AM	ADDRESS	33.99203	-118.47099	TENANT IMPROVEMENT OF EXISTING COMMERCIAL AREA. T-24 ENERGY ONLY.BLDG PERMIT 18016-10000-22375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32066	15041-20000-15454	6320 N TOPANGA CANYON BLVD Suite 1650	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Issued	07/21/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title-24 (energy).  Total area = 2,794 sq. ft.  T.I. to commercial retauk first time tenant (Dejaun Jewelers).  Two new panels connected via transformer.  New lighting, recepticles, and HVAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32067	17041-20000-26346	2000 N BEACHWOOD DR	90068	4	150A189    14	5586013004	R3-1XL	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			08/02/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	10/07/2020 12:00:00 AM	ADDRESS	34.10735	-118.32151	Plan check for power and energy. Project site is a new 6-unit apartment building. Work includes a new 600-amp service and a total lighting area of 6,523 sq. ft.Note: Building permit has been issued under 15010-20000-02814	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32068	14041-10000-18118	2949 S MILITARY AVE	90064	5	120B157    34	4251005069	R1-1	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.02918	-118.42618	Install roof mounted solar system on existing residential building.  Total system size = 3.6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32069	12041-10000-16905	11920 W WILSHIRE BLVD	90025	11	129B145  1027	4263005035	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			PC Approved	07/19/2012 12:00:00 AM	ADDRESS	34.046	-118.46483	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR MCDONALD'S RESTAURANT TI. LESS THAN 100A OCCUPANTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32070	19041-10000-07351	5999 W CENTER DR SUITE 100	90045	11	102B169   961	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	33.9761	-118.38876	INTERIOR OFFICE TI. ON THE 1ST & 2ND FLOORS, INSTALLING NEW CIRCUITS, LIGHTING AND EQUIPMENT. THE LOAD GREATER THAN 400A. TOTAL AFFECTED AREA IS 55,006 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32071	12041-10000-09478	5531 N GOODLAND AVE	91607	5	174B161   477	2346001019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	06/06/2012 12:00:00 AM	ADDRESS	34.17125	-118.41213	INSTALLATION OF 8.175 KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32072	16041-20002-28164	22951 W ROSCOE BLVD	91304	12	192B097   589	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	PIN	34.22262962	-118.62405906	Changes to approved set of plans - changes include addition to lighting system/photometrics, electrical equipment, relocation of panel, load redistribution and addition of new inverter to replace some areas with unit equipment. changes noted under delta 4, 5, 6, and 7.16041-20001-28164changes to an approved set of plans. plancheck only. changes noted delta 3.  changes include new UPS and relocation of panels and redistribution of loads. plan check for power only.   (((Plan check for power and energy. Project site is a new warehouse. Work includes a new 3000-amp service, associated distribution boards and load, and a total lighting area of 42,645 sq. ft.)))Note: Building application has been filed under 16010-10000-00122	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32073	19041-10000-42097	6315 W HOLLYWOOD BLVD	90028	13	148-5A187 148	5546004014	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.10178	-118.32731	Adding lighting & outlets due to expansion of floor of club: Dejavu	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32074	18041-10000-46787	7101 S MENLO AVE	90044	8	102B197   992	6013001015	RD1.5-1	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM			Reviewed by Supervisor	12/18/2018 12:00:00 AM	ADDRESS	33.97534	-118.28937	PV2 21.2 KW AC / 26.6 KW DC roofmounted system with (71) modules, (3) inverters interconnecting through a main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32075	17041-20000-16167	12746 W JEFFERSON BLVD BLDG 3	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Info Complete	05/15/2017 12:00:00 AM	ADDRESS	33.97756	-118.41709	"PC FOR BUS EXTENSION. ADDING 600A SECTION ""MS3"" TO EXISTING 4000A SWITCHGEAR. PROVIDING TAP TO ADDED SECTION. NO OTHER CHANGES OR LOADS AT THIS TIME.  PLAN CHECK FOR POWER ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32076	17041-10000-30535	2450 N SUMMITRIDGE DR	90210	4	153B157    35	4386014012	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.11852	-118.42251	PC FOR SFD. NEW 1600A SERVICE AND ASSOCIATED LOADS. PC ONLY. PERMIT ISSUED UNDER BUILDING COMBO	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32077	19041-10000-03454	4525 W WILSHIRE BLVD STE 240	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.06211	-118.32869	Plan check for T24 only, Interior alteration to (E) office suite (6,711 SF).  Install new lights and power from existing panelboards.  No change in use or parking.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32078	15041-20001-40188	6256 N TOPANGA CANYON BLVD Building B	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	*****VOID*****Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size 56 kWac and consists of (2) inverters, (1) load center, and (228) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32079	18041-10000-23197	6400 N OWENSMOUTH AVE A-C	91367	3	180B105    64	2146005027	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.18653	-118.6013	T-24, PC for energy only. This is a play room for kids  T.I  consists of lighting and title 24. Total affected area is 9740 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32080	17041-20001-27769	16238 W RAYMER ST	91406	6	189B137    19	2205029037	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.21771	-118.48681	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 86.6 kWac and consists of (3) inverters, (310) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32081	19041-10001-40066	5702 N MELVIN AVE	91356	3	174B117   708	2153026034	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	34.17456	-118.55988	EXPEDITED PLAN CHECKPLAN CHECK FOR ROOF MOUNTED 13.6KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE6000H-US & SE7600H-US) WITH 39 MODULES USING P400 OPTIMIZERS CONNECTED TO EXISTING 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32082	12041-10000-13858	21730 W SHERMAN WAY	91303	3	183B105   151	2111025002	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Info Complete	08/28/2012 12:00:00 AM	ADDRESS	34.20086	-118.60267	Plan check for power. Changes to original approved plan (changes are to power only, not lighting) under 11041-1000-11755:[CHANGE OF USE FROM RETAIL TO RESTAURANT IN EXISTING SINGLE STORY BUILDING.  PLAN CHECK FOR ENERGY AND POWER.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32083	19041-20000-07658	4507 W WAWONA ST pv1	90065	14	160-5A219 191	5683038015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	04/27/2019 12:00:00 AM	ADDRESS	34.13372	-118.22602	pv1install roof mounted pv system sized 5.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32084	13041-10000-01278	1234 W 254TH ST	90710	15	036B197  1120	7413005036	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.20	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	33.79367	-118.29868	"PLAN CHECK T24 ENERGY FOR T. I. TO STORAGE  AND MANUFACTURING AREA. PERMIT FOR NEW LIGHT FIXTURES, EXISTING BRANCH CIRCUITS. ""COMPLY WITH DEPARTMENT ORDER effective date 02/13/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32085	14041-10000-16818	11351 W SANTA MONICA BLVD	90025	11	129B149   499	4261004014	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Info Complete	10/16/2015 12:00:00 AM	ADDRESS	34.04611	-118.45039	"1200A SERVICE UPGRADE FOR EXISTING COMMERCIAL BUILDING.""COMPLY WITH DEPARTMENT ORDER effective date01/16/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""INVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 01/16/2009 by Inspector DALE SCHWARTZ atphone# (310)417-8665.  CEIS Case Number is 245553.Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.(Created: IMSV7 / 01-12-09)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32086	15041-10000-28288	929 N CYPRESS AVE	90065	1	145-5A219 184	5453022900	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.09307	-118.22495	PC for energy only, T-24. to an existing bldg. (family center). Scope of work: instal one light fixture. Total sq ft = 171	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32087	15041-20000-20022	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	Title 24 plan check only.  Total area = 444,065 sq. ft.  Lighting retrofit to existing parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32088	12041-20000-09474	6600 N TOPANGA CANYON BLVD #2000	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM			PC Approved	04/26/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	ENERGY ONLYNEW LIGHTING AND POWER, RELOCATE PANELS.( EXIST. PEMIT 12041-30000-09383 ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32089	19041-10000-52463	6416 N TAMPA AVE	91335	3	180B117   788	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	02/22/2021 12:00:00 AM	ADDRESS	34.18712	-118.55327	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY.OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32090	19041-10000-42333	6160 N LAUREL CANYON BLVD BLDG B130	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	PLAN CHECK FOR POWER AND ENERGY.  ( FIRST TIME TENANT/MEDICAL FACILITY)SCOPE INCLUDES NEW EQUIPMENT CONNECTED TO EXISTING DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32091	15041-20000-40554	6742 N SUNNY BRAE AVE	91306	3	180B109    83	2148001007	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.19314	-118.58067	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel. Using standard plan. (14) Sunmodule SW 280 Modules(1) Solaredge SE3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32092	17041-20001-14776	1713 S WESTERN AVE	90006	10	126B193  1421	5073012034	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.04227	-118.30925	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE TO LIGHTING CONTROLS ONLY. NOW USING WIRELESS CONTROL SYSTEM. PERFORMANCE OF CONTROLS REMAIN. NO CHANGE IN T24. RESTAMP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32093	11041-20001-10923	12925 W RIVERSIDE DR 400	91423	4	168B161   392	2358021015	C1.5-1VL, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	34.15778	-118.41435	DELTA 1 REVISION TO APPROVED PLAN CHECK T24 ENERGY. REVISE CALCULATION AND LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32094	19041-20000-47585	7301 N TOPANGA CANYON BLVD	91303	3	186B101   880	2023006031	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	06/24/2020 12:00:00 AM		Issued	06/24/2020 12:00:00 AM	ADDRESS	34.20301	-118.60617	PV3.  Installation of 107.8 kW DC roof mounted PV system.  (280) modules with microinverters.$0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32095	14041-10000-28882	12751 W MILLENNIUM Suite A115	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Plan check for power and lighting for a single suite in a new retail space building. First time tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32096	17041-30000-08987	11110 N RUFFNER AVE	91344	12	210B137   408	2682019001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.27225	-118.49763	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32097	19041-10000-02190	1030 E VERNON AVE	90291	11	111B145   189	4243027010	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Issued	01/29/2019 12:00:00 AM	ADDRESS	34.00343	-118.46226	pc for 2 energy storage system 14kw. Tesla power wall model.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32098	18041-10000-18632	1333 S BEVERLY GREEN DR 1-4	90035	5	129B165   130	4330004010	[Q]RD2-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			05/18/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.05319	-118.40537	NEW FIRE ALARM SYSTEM IN A NEW 4 UNIT APARTMENT BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32099	13041-10000-28957	2911 S ORANGE DR	90016	10	120B177   440	5049021049	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.02726	-118.35544	PV1.  Install 3.672 kW AC roof-mounted solar array, interconnect with main service panel.  Enphase M215 microinverters.  17 modules: LG 260NIC-G3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32100	16041-10001-06075	2828 N NEWELL ST	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM			PC Info Complete	01/30/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	01/30/2017 Changes to an approved set of plans. Changes include add 3 new feeders with disconnect to supply another building. Changs apply to delta 2 only. Modification of Builidng Ordinances has been filed for  install 5 feeders to feed a building(Approved by Medhi)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32101	10041-10000-19052	10000 W REGENT ST 1-28	90034	10	120B165   830	4313006001	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2699.01	Electrical	Electrical	Public Safety Only			09/24/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.02498	-118.40155	NEW FIRE WARNING SYSTEM FOR A 28 UNITS APT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32102	14041-10000-04298	5826 W OLYMPIC BLVD	90019	4	132B177   757	5085003031	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			02/14/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.05724	-118.35691	NEW FIRE ALARM SYSTEM FOR 4 STORY APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32103	18041-20000-30161	24209 S ROSCOE BLVD	91304	12	192B089   183	2017038015	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.21965	-118.65434	PV1.  Install 2.835 kW roof mounted grid tied PV system.  (9) modules at 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32104	14041-10000-00865	11100 W SANTA MONICA BLVD #1950	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	permit to be pulled at epc counter only. pc for energy only. less than 400A per applicant. hirise. TI to (e) office #1950 (remodel).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32105	10041-20000-25093	1121-1141 N AVALON BLVD	90744	15	033B205   754	7420021021	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	33.78539	-118.26305	Upgrade service to 800 amp for YMCA.  Install new switchboard, subpanels, branch circuits, and lighting.  Plan check for power and energy.  A variance for Fire Alarm submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32106	13041-20001-33865	19541 W BLACKHAWK ST	91326	12	204B117   137	2708004014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			PC Approved	12/14/2013 12:00:00 AM	ADDRESS	34.2579	-118.55952	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.0KWAC. 22 MODULES AND 1 INVERTER. SUBMITTED PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32107	15041-10001-32457	6033 S CENTRAL AVE	90001	9	105B209    92	6007007022	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			Reviewed by Supervisor	10/06/2015 12:00:00 AM	ADDRESS	33.98492	-118.25673	PV2, roof mounted solar system 159.250kW DC  on (E) 3 story storage build.  (612) Modules: SW 260 Poly(5) inverters: (4) CPS SC28KTL-DO/US-480, and (1) CPS SC23KTL-DO/US-480(1) solar subpanel(1) AC Disconnect***Expedite per applicant***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32108	16041-10000-05405	22222 W VICTORY BLVD BLDG G	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUDRY ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32109	17041-20001-39331	8303 W KYLE ST	91040	7	207B189   449	2555012009	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM			Reviewed by Supervisor	11/08/2017 12:00:00 AM	ADDRESS	34.26486	-118.31376	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.10kW ungrounded system. (35) 300W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32110	13041-10000-12856	10960 W WILSHIRE BLVD FLOOR 21-FLOOR 22	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			PC Approved	05/20/2013 12:00:00 AM	ADDRESS	34.058	-118.44597	TI to highrise tenant space (21st and 22nd floors).  Lighting redesign for 21st floor meeting rooms and lounge, and 22nd floor lounge.  2885 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32111	14041-20000-23499	2805 S ABBOT KINNEY BLVD E	90291	11	108B149  1669	4229013004	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Closed	02/01/2017 12:00:00 AM	ADDRESS	33.98826	-118.45306	Plan check for energy only. New lighting system (incl. emergency) for new nail salon (previously an office) located in business plaza. 1008sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32112	16041-20000-13229	13241 N FELLOWS AVE	91342	7	225B149   387	2505024041	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.31108	-118.45127	$0 permit fees due to senate bill 1222Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (54) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32113	11041-10000-16499	3571 W WILSHIRE BLVD	90010	10	132B193    19	5503025013	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.06192	-118.3025	T.I.  Existing retaurant in a single story building.  Remodel of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32114	14041-20000-16450	16000 W VENTURA BLVD suite 405	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.15584	-118.48164	Plan check for energy only. New lighting (incl. emergency) on 4th floor of high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32115	14041-20000-21073	15716 W HART ST	91406	6	183B141   472	2224030021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.19743	-118.47566	New roof mounted PV system with total system size 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32116	18041-10000-43597	11100 W SANTA MONICA BLVD 11Th Flr	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI IN EXISTING CORRIDOR AND PUBLIC RESTROOMS OF 11TH FLOOR. T-24 ENERGY ONLY. BULDING PERMIT: 18016-10000-35478	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32117	12041-10000-12406	11869 W LAURELWOOD DR	91604	2	162B169   361	2369027022	[Q]RD1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2012 12:00:00 AM	05/30/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.1414	-118.39138	PV system for a single family dwelling. 7.35kW. Roof mounted and transformerless.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32118	17041-20000-19912	2605 S SEVERANCE ST	90007	9	123A201   196	5123002022	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM			PC Approved	06/13/2017 12:00:00 AM	ADDRESS	34.03007	-118.28128	"plan check for power.  additional load added to existing distribution board ""MH"" providing peak demand readings.  this is plan check only.  permit fees paid under application number 17041-90000-18448"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32119	11041-10000-17819	6112 N LINDLEY AVE BLDG 2	91335	5	177B125   657	2123024025	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	34.18096	-118.52711	change of use from SFD to classroomsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32120	14041-20000-13536	15424 W SUNSET BLVD	90272	11	129B125   501	4412001017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM			Corrections Issued	05/28/2014 12:00:00 AM	ADDRESS	34.04806	-118.52795	Plan check for Energy only. Gelson's supermarket, modification of existing lighting and addition of new track lighting. Tailored method - 24,564sqft. Emergency light locations/wiring are existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32121	17041-10000-08342	19867 W PRAIRIE ST	91311	12	198B113   114	2761040022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.23927	-118.56657	PC FOR A NEW FIRE ALARM SYSTEM ON EXISTING COMMERCIAL SPACE. SCOPE INCLUDES 1 FA DEVICE AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32122	13041-20001-02321	11757 W CHENAULT ST	90049	11	132B145   386	4401013003	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.05511	-118.46941	PC FOR CHANGE IN DESIGN. 2 OPTIONAL GENERATORS INSTEAD OF A SINGLE ONE. PC FOR CHANGES CLOUDED. PLANS UPDATED 1/30. ENSURE GEN-1 HAS A 1500A TRIP SETTING FOR WIRE SIZE PROTECTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32123	12041-10000-30785	"12746 W JEFFERSON BLVD ""3"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check power and energy for Building 3. Retail/Theater shell on top of common subterranean parking with Building 1, 2, and 4. Service supplying Building 3 and Building 4. Site located in methane zone. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32124	18041-10000-46342	3113 W BEVERLY BLVD	90057	13	138A201   201	5156010010	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.07215	-118.28257	TI TO (E) FITNESS CENTER, T24 ONLY, TOTAL SQFT 1270	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32125	18041-10000-30257	260 S KINGSLEY DR	90004	10	135B193   154	5517020016	R1-1	Central	Wilshire	Wilshire Center-Koreatown		2114.20	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.06942	-118.30273	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 3.8KVA SYSTEM WITH 11 MODULES USING (P370 OPTIMIZERS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32126	11041-10000-25553	2200 W OLYMPIC BLVD	90006	1	130-5A201 159	5136014025	C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.05198	-118.28133	New 600A service and, panel, and circuits for a hotel T.I.  Previous service was 400A.  Full plan check.   (There are two existing permits 10041-10001-08054 & 10041-10002-08054)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32127	15041-20002-08331	17823 W CHATSWORTH ST	91344	12	207B129   365	2712030017	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	05/17/2016 12:00:00 AM	ADDRESS	34.26513	-118.52237	"05-17-2016 Changes to an approved set of palns. Changes include add new lighting fixture type  ""J"" and ""K"". Changes apply to delta 3 only. {{{{{{{{02/17/2016 Changes to an approved set of plans. Changes have been made to the lighting and power floor plans. All changes have been clouded and marked as Delta 2.*****Previous Work Description*****Plan check for power and  energy T.I. for restauruant and new service 400A. Total area: 3252 sq ft.}}}}}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32128	09041-20001-20042	137 N SOTO ST	90031	14	127-5A223  76	5183005019	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.20	Electrical	Electrical	Apartment			11/02/2010 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	PIN	34.04483599	-118.20951047	revision add fire pump and 3 ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32129	16041-30000-28597	2049 S CENTURY PARK EAST 24th Floor-Lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Issued	11/03/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check Title 24 only in existing high-rise elevator lobby 24th Floor. Total area: 300 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32130	19041-10000-07272	22363 W DEVONSHIRE ST	91311	12	204B101    96	2723008***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.25817	-118.61452	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.40KWdc / 6.0KWac. (20)MODULES- CANADIAN SOALR CS3U-370MS(20)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE6000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32131	15041-20000-11928	5698 S GOLDENEYE CT UNIT 3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	33.9792	-118.41068	Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL BE RELAVENT TO UNIT # 1 OF ADDRESS 5698 GOLDENEYE CORT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32132	12041-10001-13807	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	33.97704	-118.40702	changes made to original approved set.  one panel and 35 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32133	15041-10001-10183	5450 W PICO BLVD SUITE 202	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.04862	-118.35714	CHANGES TO AN APROVED SET OF PLANS NOTE CHANGES IN DELTA 1. APPLICATION VALID WHEN MASTER PERMIT GETS PULLED. 6/16/15(((TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1335.  SCOPE OF WORK TO BE PERFORMED IN SUITE 102)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32134	14041-10000-17825	647 S FRIES AVE	90744	15	027B205   619	7440009911	PF-1D	Harbor	Port of Los Angeles, Wilmington - Harbor City	Wilmington		9800.31	Electrical	Electrical	Special Equipment			07/01/2014 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.76433	-118.26419	Plan check for power system.  Remove and replace ATS, generator, VFSs, pumps, and motors in existing industrial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32135	13041-10001-30631	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	[[[[6/30/14]]]] CHANGES TO APPROVED SET OF PLANS. DELTA 5 CHANGES ONLY.  REVIESDED LOCATIONS OF ELECTRICAL LINES, LIGHTING, SIGNAL AND COMMUNICATIONS. PERMIT TO BE PULLED UNDER MASTER APPLICATION.Building 1 of 5: Administration Bldg and Clubhouse renovation (rock garden electrical room included under club house).  Install new electrical panels, new convenience receptacles and new indoor and outdoor lighting.  Fire alarm plans included.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32136	19041-10000-46993	19525 W NORDHOFF ST	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			Corrections Issued	11/14/2019 12:00:00 AM	ADDRESS	34.23567	-118.5584	void - approved under 19041-10000-43998Energy plan check for outdoor lighting; scope includes new lighting and equipment with a total lighting area of 698-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32137	14041-20001-18679	17165 W LORILLARD ST	91344	12	213B133    39	2607004036	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM			PC Approved	02/09/2015 12:00:00 AM	ADDRESS	34.2844	-118.5071	Fee is 0.00 base on senate bill 1222 from 2012.Plan check only for changing the brand of module from Canadian solar module CS6P-250 to Trina Solar TSM-255, relocating module on roof top and changing module-number of strings from 18 and 15 to 17 and 16.(((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(33) TRINA SOLAR MODULES TSM-255(2) SOLAR EDGE INVERTERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32138	14041-20000-24070	10921 W WRIGHTWOOD LANE	91604	2	159B173   427	2380044030	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.13176	-118.36791	PERMIT FEE $0.00 DOLLARS BY STATE SENATE BILL NO. 1222Roof mounted PV system with, system size 8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32139	16041-20001-30066	23223 W LIAHONA PL	91364	3	168B093   252	2074033034	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.15459	-118.63155	EXPEDITE PER APPLICANT.PV1INSTALL ROOF MOUNTED PV SYSTEM (ACM) SIZED 10.2KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32140	16041-20000-34958	1447 N MARTEL AVE	90046	4	147B181   734	5550021013	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM			Reviewed by Supervisor	10/28/2016 12:00:00 AM	ADDRESS	34.09728	-118.35102	PLANCHECK FOR POWER AND ENERGY.  ( FOUR STORY SINGLE FAMILY DWELLING WITH ATTACHED TWO CAR GARAGE WITHIN A SUBTERRANEAN BASEMENT AND ROOF TOP DECK AT FOURTH FLOOR.  SMALL LOT SUBDIVISION.  EACH INDIVIDUAL TOWN HOME TO HAVE SEPARATE METER WITH COMMON 600A SINGLE PHASE 120/240V SERVICE.  A SEPARATE PERMIT SHALL BE ISSUED FOR EACH TOWN HOME.  CHECK BUILDING PERMITS FOR INFORMATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32141	14041-20000-30139	523 W 6TH ST suite 435	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	Plan check for energy only. TI to 4th floor office in existing high rise office building. Suite 435. New lighting only. 2,487sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32142	11041-10000-01461	820 W LOMITA BLVD 1ST FL	90710	15	036B197    70	7413021049	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM			PC Approved	01/25/2011 12:00:00 AM	ADDRESS	33.79754	-118.28973	CHANGE OF USE FROM OFFICE/ GARAGE TO OFFICE/FOOD BANKPLAN CHK IS FOR INTERIOR LIGHTING SYSTEM FOR CONFORMANCE TO TITLE 24 REQUIREMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32143	12041-10000-24960	12222 W WILSHIRE BLVD Suite #105	90025	11	126B145   356	4263001***	[T][Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM			PC Info Complete	10/18/2012 12:00:00 AM	ADDRESS	34.04288	-118.46867	TI IN AN EXISTING COMMERCIAL AREA IN SUITE #105. PLAN CHECK FOR T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32144	15041-20000-23089	12130 W MILLENNIUM 4th Floor-6th Floor	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Issued	11/04/2015 12:00:00 AM	ADDRESS	33.98008	-118.40646	Plan check for power and Title-24 (energy).  Total area = 70,000 sq. ft.  T.I. to 4th, 5th, and 6th floors of existing commercial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32145	17041-20000-15727	1026 W 34TH ST	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	PIN	34.02220977	-118.29038404	TENANT IMPROVEMENT AT 2ND FLOOR  OF (E) RECREATION FACILITY.  PLAN CHECK FOR ENERGY.  22,000 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32146	10041-10000-18475	10100 W SANTA MONICA BLVD 16th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	11/24/2010 12:00:00 AM	ADDRESS	34.06191	-118.41691	Remodel of the elevator lobby and corridor of the 16th floor.  Plan check is for lighting with emergency lighting varification.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32147	14041-10002-03471	5187 N CHIMINEAS AVE	91356	3	171B125   398	2181006021	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.16533	-118.52821	CHANGES TO APPROVED SET OF PLANS PER INSPECTORS REQUEST. PLAN CHECK ONLY.  MAKING CHANGES TO THE LOCATION OF EQUIPMENT ACCORDING TO WHERE THEY ARE INSTALLED.New roof mounted PV system with 15.39 KWdc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32148	16041-10000-42763	14624 W HART ST	91405	6	183B149   415	2219024021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.19744	-118.45175	PV1. AN ADDITION TO AN EXISTING PV ROOF-MOUNTED SYSTEM. ADDING 4.0KWac TO THE EXISTING SYSTEM.(16)MODULES-SOLARWORLD SW290(16)MICROINVERTERS-M250-60-2LL-S25	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32149	12041-10000-03014	8300 W MELROSE AVE	90069	5	141B173   486	5528015074	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM			Corrections Issued	02/09/2012 12:00:00 AM	PIN	34.08339565	-118.37047926	T.I. for an existing retail space.  New circuits and panels and lighting.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit is on application 12041-90000-02975.  (No suite number, per applicant)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32150	11041-20000-11786	15211 W VANOWEN ST 1st floor	91405	6	183B145   702	2220020020	(Q)C2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	34.19412	-118.46446	T.I.  Remodeling of exsiting Doctor's Office.  Renovating the existing exam offices and regular offices.  Buildig is 3 stories.  Renovation to take place on the first floor.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32151	10041-20001-12919	8379 W 3RD ST	90048	5	138B173   748	5511015015	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM			PC Approved	07/14/2010 12:00:00 AM	ADDRESS	34.0731	-118.37273	REVISION TO APPROVED PLAN. CHANGE WAS DONE ON THE PLAN TO MATCH INSTALLATION. Upgrading existing 400amp service to 800 amp switch board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32152	13041-20001-14720	21217 W SHERMAN WAY	91303	3	183B105    66	2112023010	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.20119	-118.59494	permit already issued under original application. this application is for pc only for t24 energy. pc for t24 energy only. ADD 15 LIGHTS.  9 NEW OUTLETS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32153	17041-20002-22165	11926 W OXNARD ST	91606		177B165   766	2339003020							Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	34.17926	-118.39314	10/12/2017changes to an approved set of plans.  changes include to add disconnect to ESS.(((((Plan check for roof-mounted solar pv system with AC coupled battery backup system for SFD.3.8kW ungrounded system. (14) 325W pv modules. (1) 5kW Tesla Powerwall 2.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32154	19041-20000-08065	7451 N FAUST AVE	91307	12	186B097   504	2022011015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.20602	-118.62099	PV1.  Install 5.04 kW roof mounted grid tied PV system.  (16) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32155	13041-10000-34384	6200 N PEACH AVE	91411	6	177B145   337	2242009011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Expired	01/27/2016 12:00:00 AM	ADDRESS	34.18323	-118.4673	PV1, Install 2.5 kw DC roof-mounted photovoltaic system interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. , power optimizer, (10) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32156	16041-10000-02575	700 W WILSHIRE BLVD 1ST FLOOR	90017	14	129A209    65	5144006020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.04863	-118.25733	T-24, TI TO A BAKERY IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. F.T 1543.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32157	19041-10000-37388	3400 N CAHUENGA BLVD WEST	90068	4	159B181   260	2425001059	C2-1LD	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.1318	-118.35189	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32158	15041-20000-11247	444 S FLOWER ST 25th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	Title-24 plan check only.  Total area = 2,080 sq. ft.T.I. to lobby, corridor, and restroom of existing commercial office highrise.  Installation of new lighting and two new recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32159	19041-10000-46796	1455 E 18TH ST	90021	14	120A213   222	5129008027	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.02298	-118.24575	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32160	14041-10000-29830	11111 W SANTA MONICA BLVD 8th Floor	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Issued	12/17/2014 12:00:00 AM	ADDRESS	34.04771	-118.44481	Energy plan check for a T.I  corridor and restrooms on 8th floor of a  high rise building. all connection are reconnected to existing circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32161	15041-10000-00196	1317 N NOLDEN ST	90042	14	157-5A227 352	5485004025	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Expired	09/02/2023 12:00:00 AM	ADDRESS	34.12423	-118.19574	Installation of roof mounted solar PV array.  Total system size = 3.6 kWacNot done online since HPOZ clearance was required.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32162	17041-30000-09011	20955 W DE MINA ST	91364	3	171B109   418	2167016017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/29/2017 12:00:00 AM	ADDRESS	34.16121	-118.59026	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (23) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32163	12041-10001-06843	1239 S ABBOT KINNEY BLVD	90291	11	108B145  1148	4239022029	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			PC Approved	08/29/2012 12:00:00 AM	ADDRESS	33.99137	-118.46835	SUPPLEMENTAL PLAN CHECK FOR REVISION TO POWER AND ENERGY FOR TENANT IMPROVEMENTS NEW RESTAURANT. NEW EQUIPMENT AND LIGHT FIXTURES NDER #11041-20000-23087. BUILDING LOCATED IN METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32164	15041-20000-06476	6016 N FALLBROOK AVE	91367	3	177B097   489	2039017037	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.17974	-118.62314	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS.  1625 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32165	13041-10000-15915	170 N GLENDALE BLVD	90026	1	135A209   230	5160013013	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.0639	-118.25974	PLAN CHECK FOR METHANE MITIGATION SYSTEM DESIGN LEVEL V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32166	19041-20000-11263	4758 N LANKERSHIM BLVD	91602	2	168B173   512	2421015001	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.1572	-118.36972	T24 PLAN CHECK FOR CHANGE OF USE FROM LAUNDROMAT TO BANK. TOTAL SQUARE FOOTAGE = 3000SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32167	17041-10000-05483	3191 W CASITAS AVE	90039	13	153B209   607	5436001021	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.11488	-118.25027	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR) 31625 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32168	10041-20001-09602	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur	YES	2088.02	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.06086	-118.27891	revise fire pump disconnect to 600 amps and add 2500A  section	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32169	17041-10000-00105	101 S JAPANESE VILLAGE PLAZA MALL	90012	14	129A215   347	5161017022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.04935	-118.23977	01/03/17 Changes to an approved set of plans, changes are under delta 3, Changes include the addition of a fuse and circuit relocation. PC ONLY***12/09/2016 Changes to an approved set of plans. Changes include remove H1 Panel and relocate panel T1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32170	15041-10000-19850	7260 WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM			PC Info Complete	07/01/2015 12:00:00 AM	ADDRESS	33.94118	-118.41971	TI TO AN EXISTING BUILDING.  RELOCATING CAFETERIA AND RESTROOMS.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 3267.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32171	18041-10000-05953	15247 W LEMARSH ST	91345	7	204B145   511	2660015017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.25554	-118.46457	Plan check for PV roof mounted system. System size: 3.0kW with 9 modules and 1 inverter(3.0kW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32172	14041-20000-11887	4732 N ARCOLA AVE	91602	4	168B177   610	2420023002	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.15678	-118.3548	PV1 ROOF MOUNTED MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 7.5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32173	14041-10001-15903	5213 E MONTE VISTA ST STE# A	90042	1	151-5A227 248	5469019024	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.10885	-118.2008	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32174	15041-20000-13724	8075 W 3RD ST #400	90048	5	138B177   725	5511022032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.07225	-118.36564	TI TO EXISTING OFFICE SPACE. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32175	18041-20000-31142	10170 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Issued	09/25/2018 12:00:00 AM	ADDRESS	34.25528	-118.57964	800A 240/120V 3ph-4w service upgrade to (E) multi-tenant commercial building.  New tenant panels. No new load in scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32176	14041-20001-05150	12698 W SANDHILL LANE UNIT2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/25/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	33.97714	-118.41552	(((EXPEDITE FEES)))((EXPEDITE FEES)))PC FOR SERIES OF PHOTOVOLTAIC SYSTEMS FOR NEW CONDOS. THIS SYSTEM IS SPECIFIC FOR UNIT 2. SYSTEM SIZE 3KW AC. SYSTEM IS TIED TO MAIN SERVICE SERVING OTHER UNITS. THIS IS PLAN CHECK AND PERMIT SUBMITTAL 2 OF 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32177	18041-20001-31362	818 W 7TH ST #1200	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM			PC Approved	10/05/2018 12:00:00 AM	ADDRESS	34.04895	-118.25943	10/05/2018 Changes to an approved set. All changes have been clouded and marked as Delta 2. Scope of work has expanded to included (2) restrooms and common corridors. All changes have been reflected onto the Title 24 compliance forms. *****Previous Work Description*****Tenant improvement of a suite on the 12th floor of an existing commercial highrise building. Note: Building application has been generated under 18016-10000-14036	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32178	15041-10000-24122	1730 W MANCHESTER AVE	90047	8	097-5A193 336	6037014024	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	33.9598	-118.3078	TI FOR EXISTING COMMERCIAL SITE (RALPHS) NEWLY CONNECTED LOAD GREATER THAN 400 APC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32179	13041-20000-06197	13219 W CUMPSTON ST	91401	5	174B157   908	2345002013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.16992	-118.42021	New Ephase (Microinverter)  Photovoltaic System for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32180	19041-10000-01096	11750 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Closed	01/31/2022 12:00:00 AM	ADDRESS	34.04843	-118.4618	Photometic PC only for High rise. temporary Ltg	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32181	14041-10000-07832	1150 S OLIVE ST 23RD FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.03962	-118.26181	TENANT IMPROVEMNT IN OFFICES ON THE 23RD FLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32182	13041-10000-32771	900 W WILSHIRE BLVD P2-P5	90017	14	130-5A209 197	5144008020	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.05001	-118.25963	Providing ground rod and ground ring all around the property line and middle in p5 level.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32183	10041-10000-09004	601 W 7TH ST	90017	9	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.0475	-118.25665	CHANGE OF USE FROM RETAIL TO RESTAURANT ( CHIPOTLE )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32184	16041-30000-04100	14801 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.17768	-118.45513	Title 24 plan check only.  Total area = 8,045 sq. ft.T.I. to existing commercial office space.  1 new panel + new lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32185	15041-10000-16717	10146 W BAYWOOD CT	90210	5	153B153    54	4382029***	RE15-1-H-RPD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Expired	09/05/2023 12:00:00 AM	PIN	34.11750094	-118.44146965	PV1.  Install 7.28 kW rooftop-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32186	17041-10000-10075	3721 S LA BREA AVE 1ST FLR	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.01899	-118.35583	FULL PC FOR POWER AND ENERGY. TI AT EXISTING MEDICAL OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A DENTAL/EXAM ROOMS. TOTAL AFFECTED AREA IS 608 SQ. FT.  B#17016-10000-07521	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32187	17041-10000-01226	5021 S CIMARRON ST	90062	8	111B189  1413	5015022026	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	33.99732	-118.31617	PV, INSTALATION OF NEW 4.24 KW DC/4.028 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(16) MODULES: AXITEC AXIPOWER AC-265P/156-605(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32188	17041-10000-44780	19191 S VERMONT AVE 7th floor	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR OFFICE TI (7TH FLOOR) . SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 20256 SQ FTB# 17016-10000-36996	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32189	17041-10000-22424	1001 S BROADWAY unit F	90015	14	126A209    61	5139013022	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM			PC Info Complete	07/20/2017 12:00:00 AM	ADDRESS	34.04086	-118.25782	Plan check for power and Title 24.  T.I. and change of use from retail to optometrist including exam rooms.   Total area = 914 sq. ft.       Building permit #17016-10000-17730	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32190	13041-10001-17983	14059 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.14947	-118.43889	7/17/14   CHANGES TO APPROVED SET. DELTA 7 CHANGES ONLY. CHANGES ARE CLOUDED. ADDING  OF 3 AIR CONDITIONING AND CHANGING ENERGERGY MANAGEMENT SYSTEM.PLAN CHECK FOR POWER AND ENERGY FOR NEW WELLS FARGO. 3990 SQRFT.This approved set to be referenced for most up to date calculated load on MSB.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32191	10041-10000-19730	621 S BROADWAY	90014	14	129A211   199	5144003014	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			10/05/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	01/06/2011 12:00:00 AM	ADDRESS	34.04621	-118.25267	title 24 , and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32192	17041-10000-44332	1034 S GRETNA GREEN WAY	90049	11	129B145  1030	4264025024	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.04577	-118.46924	Plan check for battery backup system. Battery backup system size: 13.5 kWh , and (1) 125A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32193	19041-20000-16090	5610 N CAMELLIA AVE	91601	2	174B169   787	2338028034	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	12/12/2020 12:00:00 AM	ADDRESS	34.17257	-118.38211	Plan check for a fire alarm system for a 4-story, 62-unit apartment building. Fire alarm consists of (1) FACP and (118) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32194	13041-10001-27321	202 N GRAMERCY PL	90004	4	138B193   763	5516020011	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM			Reviewed by Supervisor	10/18/2013 12:00:00 AM	ADDRESS	34.07484	-118.31233	][][]EXPEDITED PER APPLICANT REQUEST ][][][]PV1 , ROOF-MOUNTED SOLAR ARRAY OF A 4.9 KW DC PV SYSTEM IN A 2-STORY HOME. ENPHASE 215-60-2LL-S22-NA MICRO-INVERTERS ON A NON-STANDARD PLAN WITH 20 MODULES (HANWHA HSL 60, 245W MODULE )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32195	18041-10000-40167	2626 W COLORADO BLVD	90041	14	163-5A219 162	5682002024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM			PC Info Complete	12/04/2018 12:00:00 AM	ADDRESS	34.14192	-118.22342	PC FOR POWER AND ENERGY ROR TI TO (E) RETAIL (TARGET) INCLUDING RELOCATION OF PHARMACY AND STARBUCKS. TOTAL CONNECTED LOAD >400A. TOTAL AFFECTED AREA 120,870SQ.FT  B#18016-10000-16452	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32196	18041-10001-00702	18400 W BURBANK BLVD	91356	3	174B125   488	2160010037	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM			PC Approved	08/07/2019 12:00:00 AM	PIN	34.17045874	-118.53384937	change to an approved set. change include changing the feeder to panel EV-1 from (3 sets of #350) to (2 sets of  250) on the primary and from ( 3 sets of #300)to (2 sets of #600) on the secondary size . change also includes upsizing elevator feeders and conduits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32197	11041-20000-27672	127 S SAN VICENTE BLVD Bulletin-105TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM			PC Approved	12/30/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin # 105 T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32198	16041-10000-14334	1801 CENTURY PARK EAST FLOOR #8	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	PIN	34.0621869	-118.41581732	COMMON AREA REMODEL OF 8TH FLOOR. RESTROOM AND HALLWAY. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32199	12041-20000-06807	5662 W HOLLYWOOD BLVD	90028	13	148-5A193 171	5544026001	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.10155	-118.31339	"REPLACE 14 LIGHT FIXTURES OFF EXISTING BRANCH CIRCUITS""COMPLY WITH DEPARTMENT ORDER effective date06/05/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32200	15041-20002-40911	4919 N BLUEBELL AVE	91607	4	168B161   169	2357020004	R1-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM			PC Approved	01/04/2016 12:00:00 AM	ADDRESS	34.15993	-118.41174	1.4.2016 - Plan check for modifications to approved plan. Combine strings not on roof, but inside attic near inverter. Update string/conduit details and conductor counts to reflect this change. Combine strings using polaris connectors inside a junction box instead of using a fused combiner box.[[[PV1, roof mounted solar panel 11.4kW AC system interconnect with (N)225A service.(35) modules: LG315N1C-G4(1) inverter: SE11400a-usPower optimizer is used.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32201	10041-10001-09245	1301 S SOTO ST	90023	14	121-5A221 184	5170016029	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM			PC Approved	07/13/2010 12:00:00 AM	ADDRESS	34.02612	-118.21991	Revision to the approved plan . ((((((((((((((T.I. to existing restuarant building.  Install general and emergency light.  Plan check for Title 24 only.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32202	16041-30000-42238	11755 W WILSHIRE BLVD #10	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	PIN	34.04869377	-118.46238681	Plan check for Title 24 only. Project site is a suite on the first floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,304 sq. ft.Note: Building application has been generated under 16016-30000-28749	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32203	13041-10001-24655	1258 N HIGHLAND AVE	90038	4	144B185   132	5532005028	C2-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.09419	-118.33842	REVISIONS TO PERMITTED SET OF PLANS-FEW NEW CKTS AND CHANGE TO LIGHTING(((((((((INTERIOR ALTERATION OF 3-STORIES COMMERCIAL BUILDING; SERVBICE IS EXISTING;NEW PANEL BOARDSAND CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32204	12041-10000-04221	4015 1/2 W BRUNSWICK AVE	90039	13	157-5A207 117	5594027028	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM			Ready to Issue	03/27/2012 12:00:00 AM	ADDRESS	34.12556	-118.26593	(10) SOLAR PANELS ON SFD ROOF. Solar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.(*NOTE* Express permit was previously issued under PCIS 11041-10000-27076; supplement fees for 9 INV & one panel)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32205	19041-10000-52426	8527 N KELVIN AVE	91306	3	192B109   141	2780003050	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.22522	-118.58646	[EPLAN] 0$ FINAL FEES PER AB1414NEW PV1 ROOF MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 16.8KW DC/ 11.2KW AC, 48 MODULES (LG-350), 48 ENPHASE MICROINVERTERS (IQ7-60-2-US), 1 COMBINER BOX, 2 ESS (TESLA POWERWALL), 3 SUBPANEL RATED 125A AND TWO FOR 200A, AND EXISTING 200A MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32206	15041-10000-05482	3770 N CAHUENGA BLVD	91604	4	162B177   423	2425001069	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.13641	-118.3623	TI FOR RESTAURANT. NEW 600A SERVICE AND NEW LOADS AND TITLE 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32207	14041-20000-01153	117 E MAST MALL	90292	11	102A147   131	4295003007	R1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	33.97332	-118.45914	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32208	15041-10001-35947	345 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			Corrections Issued	12/28/2016 12:00:00 AM	ADDRESS	34.05424	-118.25562	TITLE 24 FOR TI (EXISTING KITCHEN REMODE. SF TOTAL = 1135)UNDER ORIGINAL PERMIT 16041-10000-35947ELECTRICAL FOR KITCHEN REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32209	16041-30000-14597	445 S FIGUEROA ST #2350	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			PC Approved	04/26/2016 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for energy Title 24 only in existing space T.I. Total area: 3365 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32210	12041-10000-10253	3635 E UNION PACIFIC AVE	90023	14	118-5A227 306	5191024010	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.01665	-118.19899	REPLACING A DAMAGED VANDELIZED 800AMP SERVICE EQUIPMENT. ALL LOADS EXISTING TO REMAIN.  NO NEW LOADS ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32211	17041-10001-40989	10500 S AVALON BLVD	90003	8	090A207   178	6051028031	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	33.94087	-118.265	PC FOR NEW FA WITH VOICE EVAC. INCULDES  31  DEVICES  WITH  2  PANELS. PERMIT PAID UNDER MASTR THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32212	13041-20000-18784	2130 S SAWTELLE BLVD 1-2	90025	11	126B153   959	4260001031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.03882	-118.4416	T24 FOR COMBINING 3 UNITS INTO 1. PLAN CHECK FOR ENERGY ONLY. TOTAL SQRFT 3552	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32213	18041-20000-43433	12400 N MCLENNAN AVE	91344	12	219B133   546	2609026045	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.29504	-118.50083	PV1.  Install 11.4 kW roof mounted grid tied PV system.  (34) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32214	13041-10000-31929	1431 S LOS ANGELES ST A-B	90015	14	124-5A207 319	5133012011	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.03407	-118.26104	"TITLE 24 PART 6 ENERGY WORK FOR A 1380 SQ  COMMERCIAL BUILDING . SCOPE OF WORK IS FOR REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. ""COMPLY WITH DEPARTMENT ORDER effective date02/17/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32215	17041-20000-19501	19820 W SPLIT OAK RD	91311	12	210B113   269	2708030032	(T)(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.27022	-118.56506	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32216	13041-20000-05016	1126 S WESTWOOD BLVD	90024	5	132B153   211	4363022006	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.06019	-118.44486	Plan check for energy and emergency lighting. TI. Salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32217	18041-10000-38399	200 N NORTH MAIN ST	90012	14	130-5A213   3	5161014901	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	09/28/2021 12:00:00 AM	ADDRESS	34.05326	-118.24219	INSTALLATION OF NEW PREACTION PANEL TO EXISTING FIRE ALARM SYSTEM.WORK DONE ON LEVEL P4. 210 NEW DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32218	14041-20000-05871	23824 W TIARA ST	91367	3	177B089   733	2045016010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.17853	-118.64555	Roof mounted PV system with 5.9KWdc.Note: Permit include 225A panel upgrade.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32219	15041-20001-14421	19333 W SANTA RITA ST	91356	3	171B117    96	2163004011	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM			Reviewed by Supervisor	05/28/2015 12:00:00 AM	ADDRESS	34.16778	-118.5546	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32220	19041-10000-37413	800 E 12TH ST 401-402	90021	14	123A211   489	5132012***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	09/01/2020 12:00:00 AM	ADDRESS	34.0321	-118.25055	ENERGY PC FOR TENANT IMPROVEMENT OF (E) OFFICE SPACE. AREA OF SCOPE 4,095 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32221	10041-10000-23139	1166 S SOTO ST	90023	14	121-5A221  24	5170005026	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2047.00	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.02828	-118.2191	UPGRADE AN EXISTING CAR WASH IN AN EXISTING GAS STATION. INSTALL A NEW 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32222	14041-20000-06961	1150 S OLIVE ST #2250	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.03962	-118.26181	T.I. to existing building on 22nd floor.  Install and relocate lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32223	15041-20000-06197	13460 W ALMETZ ST	91342	7	231B157   217	2582016015	RS-1	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Expired	03/28/2017 12:00:00 AM	ADDRESS	34.32737	-118.42633	Installation of new roof mounted solar PV array.  Single inverter system.  Total size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32224	16041-10000-25646	2049 S CENTURY PARK EAST 2750	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Electrical Plan check for Title 24 only. Plan check for 1040 sqft.**INTERIOR OFFICE TI FOR EXISTING TENANT SPACE ON THE 27TH FLOOR. WORK ALSO INCLUDES DEMOLISHING EXISTING DEMISING WALL AND CONVERT 2 SUITES INTO ONE. SCOPE OF WORK +/- 993 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32225	12041-20000-27653	12752 W WEDDINGTON ST	91607	5	171B161   341	2346024002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.16653	-118.41126	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32226	13041-20000-12711	1000 S CARMELINA AVE	90049	11	126B141   123	4264021031	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.0441	-118.47284	New Ungrounded Photovoltaic System for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32227	11041-20000-00886	10866 W WILSHIRE BLVD #740	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.05907	-118.442	T.I. to a high rise building of 7th floor.  Install general/emergency lighting.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32228	19041-10000-26473	1117 W 190TH ST	90248	15	060B197   543	7351028010	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Info Complete	01/16/2020 12:00:00 AM	ADDRESS	33.85849	-118.29538	Full plan check for a  CHANGE OF USE FROM SHOP OFFICE TO BAKERY that includes extraction (hazadous location, class 1 div1) with new 800-Amp service and all new equipment. Total lighting area is 10,017-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32229	12041-10001-21774	801 E COMMERCIAL ST	90012	14	130-5A217 174	5173019006	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			PC Approved	03/20/2013 12:00:00 AM	ADDRESS	34.05272	-118.231	T24 supplemental plan check for outdoor lighting on roof and for hardscape areas.  Additional outdoor lighting added to plan in form of 23 metal halide luminaire J to roof for facade lighting.((((RENOVATIONS IN THE OFFICES OF A STORAGE BUILDING-1ST FLOORPLAN CHK IS FOR TITLE 24 FOR INTERIOR LIGHTING SYSTEMONLY))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32230	14041-10000-33505	1147 S BRONSON AVE	90019	10	129B189   409	5081003015	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.05128	-118.32369	Installation of a roof-mounted PV system. System consists of (2) inverters and (66) modules in (6) strings. System size is 15.2 kWac. Zoning cleared on building permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32231	18041-10000-04270	16514 W NORDHOFF ST	91343	12	195B137     8	2688001013	A2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.23553	-118.49263	PC for T24 only for replacement of outdoor metal halide fixture with new LED fixtures. Total area 54250sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32232	15041-20001-30833	6301 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	34.18467	-118.60176	01/10/2017 Changes to an approved set of plans (Application 15041-20000-30825). Changes have been made to the lighting floor plan. Changes have been reflected onto the Title 24 Compliance Forms. Note: Supplemental application for 15041-20000-30825 has been created under 15041-20000-30833 because 15041-20000-30825 has been finaled by the inspector. Inspector Martinek was notified of this issue. *****Previous Work Description*****TENANT IMPROVEMENT FOR A (N) KITCHEN & SERVERY.  pc for power and energy. part of total ti package.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32233	13041-10001-07298	415 S LA BREA AVE	90036	4	135B181   428	5508006028	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	06/04/2013 12:00:00 AM	ADDRESS	34.06635	-118.34436	Plans are revised and indication is the service of 2000 Amps been approved under 12041-10001-27648.  however it should be treated as new. all other panels and work is new under this submittal 2, submittal 1 did not show the whole picture.  Need to verify DWP report, marked up set is a part of submittal 2.  Please tyalk to Nabil at time of checking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32234	12041-20000-24234	6060 W OLYMPIC BLVD A101	90019	10	132B177   670	5086001066	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	PIN	34.05782845	-118.36339619	relocate lighting & power, add some receptacles and switch.  Load is less than 400 Amps, PLAN CHECK ONLY for T-24, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32235	19041-20000-36623	7315 N RUTHERFORD HILL DR	91307	12	186B089   598	2027043020	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Issued	09/13/2019 12:00:00 AM	ADDRESS	34.20372	-118.65172	PV1.  Install 16.1 kW roof mounted grid tied PV system.  (46) modules with(2) 7.6 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32236	19041-10000-06933	5868 S CROCKER ST	90003	9	108B205  1260	6006030030	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	33.98815	-118.2684	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32237	18041-10000-42780	19420 W VALERIO ST	91335	3	186B117   633	2116017035	RD5-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.20462	-118.55621	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32238	17041-10000-11629	910 S GRAND VIEW ST	90006	1	132A201   360	5136005014	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Apartment			04/11/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.05394	-118.28101	PC FOR POWER AND ENERGY FOR EXISTING 4 STORY 40 UNIT APPARTMENT(TI-REMODEL). SCOPE CONSIST OF USING EXISTING SERVICE RATED AT 800A, AND REPLACING ALL UNIT PANELS WITH NEW SERVICE LOAD CALCULATIONS. ALL UNITS ON THE 4TH FLOOR(10 UNITS TOTAL) SHALL NOT HAVE AC UNITS TO ACCOMODATE FOR EXISTING SERVICE SIZE. TOTAL AREA  8145 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32239	19041-10000-34529	942 N NORTH BROADWAY	90012	1	135A215   166	5414013014	C2-2	Central	Central City North	Historic Cultural North		2060.10	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			PC Info Complete	04/06/2021 12:00:00 AM	ADDRESS	34.06503	-118.23675	FULL PLAN CHECK FOR A NEW 25 STORY MIXED USE BUILDING, RESEDNTIAL AND COMMERCIAL. SCOPE OF WORKS INCLUDES A NEW 5000A SERVICE FEEDING VARIOUS DISTRIBUTION BOARDS, VARIOUS EQUIPMENT, AND TWO FIRE PUMPS. TOTAL AFFECTED AREA IS 200,282 SQFT. B#19010-10000-01983	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32240	19041-20000-37358	222 S MAIN ST	90012	14	130-5A213 144	5161026040	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM			Reviewed by Supervisor	10/03/2019 12:00:00 AM	ADDRESS	34.05047	-118.2448	Power and lighting for first time tenant for new commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32241	19041-10000-19751	10560 W MAGNOLIA BLVD	91601	4	171B177   735	2419017001	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/09/2021 12:00:00 AM	ADDRESS	34.16472	-118.36133	POWER AND ENERGY PLAN CHECK FOR A TI OF AN EXISTING OFFICE & AUTOMOBILE REPAIR GARAGE.  SCOPE INCLUDES NEW 400A SERVICE 120/240, EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 5066 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32242	13041-10000-13703	7955 N LARAMIE AVE	91306	3	189B113   523	2107019086	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03, 1341.04	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.21537	-118.5731	PV1.  Install roof-mounted solar array, 9.555 kW DC system size, interconnect with existing main service panel.  {39 modules: TSM-245 PC/PA05} {Central inverter: SunnyBoy 7000-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32243	12041-10000-06309	1524 W PALOS VERDES DR NORTH BLDG V	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77934	-118.30435	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building V. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32244	15041-10000-39946	12751 W MILLENNIUM # 4115	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	TI TO BIKE SHOP. FIRST TIME OCCUPANCY. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32245	16041-20000-01430	18500 W VENTURA BLVD	91356	3	171B125    74	2161018045	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM			PC Info Complete	01/14/2016 12:00:00 AM	ADDRESS	34.16847	-118.53571	Plan check for hazardous location only. Install a new 20A breaker to feed a 1.5HP motor w/motor rated switch for 499 gallon propane tank.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32246	15041-20000-21033	19411 W MARILLA ST	91324	12	201B117   282	2761008020	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	10/31/2015 12:00:00 AM	ADDRESS	34.24755	-118.55617	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32247	19041-10000-49011	11526 W KILLION ST	91601	2	174B169  1014	2350007016	[Q]RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.17117	-118.38314	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 5KWac/6.17KWdc. SCOPE OF WORK INCLUDES 19 MODULES (HANWHA Q-CELL 325 W) WITH OPTIMZERS (SE P320), A CENTRAL INVERTER (SE5000H-US) AND A NEW 125A SUBPANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32248	11041-20000-08187	2029 S CENTURY PARK EAST 38th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	08/23/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to existing high rise building of entire 38th floor.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32249	14041-20000-09362	8454 N SUNLAND BLVD	91352	6	192B177   217	2404023014	(Q)C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.22392	-118.36537	dental office	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32250	14041-10000-17883	410 N BUNDY DR	90049	11	135B141   474	4402013010	R1-1, RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.06571	-118.47613	Install roof mounted solar pannels on existing two story residential building.  Total system size = 3.8 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32251	13041-20000-01326	9101 N SEPULVEDA BLVD	91343	7	198B145   385	2656026012	C2-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.23576	-118.4679	Plan check for energy and power. Existing service. Affected load is greater than 400A. Laundromat. 6724sqft. Smoke shop, PANEL SA, is on a seperate permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32252	16041-20000-19797	14440 W DICKENS ST	91423	4	166-5A151 231	2266006050	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.14956	-118.44755	PV2.  Install 56.94 kW roof mounted PV system.Note: Fee $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32253	15041-10000-14936	10423 W TUXFORD ST	91352	7	198B177   196	2544022016	RE40-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.23561	-118.35812	PV1 INSTALL 12.22 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (47) MODULES: KYOCERA  KU2606XPA(2) INVERTER: PVI-5000-PUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32254	14041-10000-14921	1624 W 7TH ST	90732	15	015B193   172	7559033015	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			Reviewed by Supervisor	06/20/2014 12:00:00 AM	ADDRESS	33.73837	-118.31278	PV1, INSTALL 7.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON ONE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32255	19041-20000-20709	5030 N CANOGA AVE	91364	3	168B105    45	2167009001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.16045	-118.59601	Plan check for a PV1 roof-mounted PV system. System size is 9.36 kWdc/8.19 kWac and consists of (26) AC PV modules and (2) load centers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32256	19041-10001-02901	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	CHANGES TO AN APPROVED SET OF PLANS.ALL CHANGES ARE CLOUDED UNDER DELTA . NOTE: PC ONLY. PERMIT PULLED UNDER PCIS#19041-10000-02901	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32257	16041-20000-14717	3411 E 15TH ST	90023	14	117A225   110	5192013032	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Expired	05/29/2018 12:00:00 AM	ADDRESS	34.01586	-118.20638	Plan check for energy only. TI to existing industrial warehouse. New lighting (incl. emergency) and receptacles. 9,255sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32258	17041-10000-21499	2201 E WASHINGTON BLVD	90021	14	118-5A215   6	5167019900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			Reviewed by Supervisor	07/26/2017 12:00:00 AM	ADDRESS	34.01911	-118.23383	PC for commercial rooftop solar. PC for new 170 kW system with 616 modules and six load centers. Plan checker to remove all electrical sheets related to interior TI work on plan (Under different permit).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32259	16041-20000-44306	1250 N BEL-AIR ROAD	90077	5	147A153   463	4370029011	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	02/08/2020 12:00:00 AM	ADDRESS	34.09618	-118.44375	"""0$ permit fees due to senate bill 1222""Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 600A MSP.18.72kW ungrounded system. (78) EnPhase M250 microinverters. (78) 280W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32260	11041-10000-27321	1801 E 50TH ST	90058	9	111A213   156	5106027004	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	33.99812	-118.24177	This is anew factory for clothing, two story , title 24 and emergency lighting, power, lighting, new panel, lighting ckts, 50 new cktsand non dewling power equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32261	13041-10001-24705	2436 N GRIFFITH PARK BLVD	90039	4	150A205   371	5432006020	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.10382	-118.27199	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32262	12041-20000-07086	5901 W OLYMPIC BLVD	90036	4	132B177   666	5086024025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.05771	-118.35996	TI for a pharmacy, retail. T-24 Plan Check for Energy and emergency lighting. 2541 sqft conditioned area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32263	17041-10000-19248	10250 W SANTA MONICA BLVD FC-21	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC for power and energy for first time tenant ice cream shop. Total area is 391 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32264	17041-10001-36625	2024 W 62ND ST	90047	8	105B189  1020	6001020015	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	33.98325	-118.31436	PC FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL BUILDING. SYSTEM SIZE 19.8KWDC / 23KWAC. SCOPE INCULDES 66 PANELS WITH SINGLE INVERTER. ADDITIONAL SYSTEMS ARE INSTALLED ON SAME ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32265	16041-10000-05128	1647 N MANDEVILLE CANYON ROAD	90049	11	135B137   621	4426001016	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.06264	-118.49378	PV1, INSTALL NEW 12.9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(43) MODULES: SILEVO TRIEX U300 BLACK(2) INVERTERS: ABB PVI 5000&6000-OUTD--US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32266	17041-20000-08969	13760 W FOOTHILL BLVD stall 1&2	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.30934	-118.43312	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy and em lighitng only.  total square footage 696.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32267	13041-10000-01935	9845 N WORNOM AVE	91040	2	201B181   164	2543032003	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.24863	-118.35209	photovoltaic system for single family dwelling. USING TOTAL OF 74 SOLAR MODULES. USING ENPHASE M215. SOLAR PANEL SUNMODULE SW240. TOTAL SYSTEM SIZE OF 15.98 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32268	17041-10000-30140	18370 W BURBANK BLVD STE 100	91356	3	174B125   449	2160011029	[Q]C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Closed	06/01/2018 12:00:00 AM	ADDRESS	34.17159	-118.53338	MEDICAL TI. PC FOR POWER AND ENERGY PER ART. 517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32269	16041-10000-15606	5225 N GOODLAND AVE	91607	2	171B161   466	2346023032	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.16555	-118.41213	PV1, rooftop solar installation 11.4 kW.   (1) SE11400A-US    (50) CS6P-265P        SEP300 is used.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32270	17041-10000-44883	1256 W 7TH ST	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.05216	-118.26774	INSTALLING 4 EA NEW LUMINAIRES IN THE FIRE PUMP ROOMPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32271	14041-10000-31854	7590 N GLENOAKS BLVD	91504	2	186B181    61	2401042012	(Q)C1.5-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Info Complete	12/16/2014 12:00:00 AM	ADDRESS	34.20894	-118.34376	plan check only. plan check for power only. Install New750kva/600kw   optional standby generator with 3000A ATS supply in a 2-stories office building. Permit fee under  14041-10000-26625.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32272	17041-20001-30507	21042 W VINTAGE ST	91311	12	201B105    28	2747003020	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2017 12:00:00 AM			PC Approved	09/06/2017 12:00:00 AM	ADDRESS	34.25121	-118.59225	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (36) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32273	13041-10000-24929	6017 E TIPTON WAY	90042	14	159A229   156	5480012011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	ADDRESS	34.13008	-118.18927	PV1. ROOFMOUNTED SOLAR ARRAY INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 3.675 kW. TRANSFORMERLESS WITH POWER OPTIMIZER. 15 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32274	19041-10000-06924	1036 S BROXTON AVE	90024	5	132B149    22	4363018904	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.06189	-118.44639	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32275	19041-10000-31006	5638 N SEPULVEDA BLVD	91411	4	174B145   394	2243003026	C2-1VL-RIO, R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	05/07/2020 12:00:00 AM		Issued	05/07/2020 12:00:00 AM	ADDRESS	34.17325	-118.46595	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN INTERIOR AND EXTERIOR ALTERATIONS OF EXISTING HOTEL. TOTAL SQ. FT. 6633	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32276	17041-10000-04126	5419 S MCCONNELL AVE	90066	11	102B157    40	4211009012	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	33.97821	-118.42002	Plan check for power and energy in existing building 1st and 2nd floor(mezanine)  office space T.I. Total area: 21,302 sq ft Load exceed 400ANote: Phase 1 of the project B#16016-10000-30830	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32277	17041-20001-02865	1520 W JAMES M. WOOD BLVD system A	90015	1	130-5A205 328	5137004029	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	03/24/2017 12:00:00 AM	ADDRESS	34.05009	-118.27201	expedite per applicant.pv2install roof mounted pv system sized 15.2kw interconnected with msp.This is system A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32278	13041-20001-34985	7525 N NITA AVE	91303	3	186B101   275	2023018020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.20729	-118.6138	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32279	19041-10002-39126	17431 W RAYEN ST	91325	12	195B129   204	2768019001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.23231	-118.51485	Plan check only. PLAN CHECK FOR LOST SET OF PLANS - NO CHANGES TO ORIGNAL SCOPE OF WORK SEE NOTES FOR INFORMATION ON ORIGINAL SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32280	09041-20001-23909	8830 W VENICE BLVD	90034		123B169  1226	4312015012	[Q]CM-1VL		West Adams - Baldwin Hills - Leimert	South Robertson			Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			PC Approved	11/15/2010 12:00:00 AM	ADDRESS	34.03044	-118.38578	Plan check only. Revision to approved plans. All changes are clouded to reflect field changes. Tenant improvement to (E) retail space with new 800A panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32281	15041-20001-27088	12629 N AMBOY AVE	91342	7	219B145    51	2604040012	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	08/22/2015 12:00:00 AM	ADDRESS	34.30064	-118.47216	Expedited per customer request.PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel.(10) Canadian CS6P-255P Modules(5) Canadian CS6P-235PX Modules(1) Solard edge SE3800A Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32282	18041-30000-42948	1423 S ABBOT KINNEY BLVD	90291	11	108B145  1348	4241036006	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM			Corrections Issued	11/08/2018 12:00:00 AM	ADDRESS	33.99059	-118.46514	PC FOR OFFICE TI ON THE FIRST FLOOR. SCOPE INCLUDESNEW CIRCUITS, LIGHTS AND RECEPTACLESTOTAL AFFECTED AREA 906 SQ.FT B#18016-30000-36113	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32283	15041-20000-21833	6316 N TOPANGA CANYON BLVD Kiosk 9010	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Closed	08/21/2018 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and Title-24 (energy).  Total area = 280 sq. ft.  T.I. for retail first time tenant.  Lighting and recepticles for kiosk space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32284	13041-10001-04663	14006 W RIVERSIDE DR 260	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	supp. to permit and plan check for t24 energy compliance. this application is for the installation and plan check for 7 neon signs. per inspector request, pc and approved set of plans for neon signs. Permit for branch circuits was already pulled under application # 13041-20000-03937.  This application was for T24 plan check only for new LED lighting fixture D.  Applicant submitted revised set of approved T24 plans(12041-10000-FILL IN) (changed lighting fixture schedule) without original approved set, so started a new OTC plan check.  (Original application description: T24.TI TO EXISTING RETAIL FOR NEW KIEHLS STORE. 1126SF space 260)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32285	12041-20000-22609	6439 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.18759	-118.59772	T.I. RESTAURANT BUILDOUT. PLAN CHECK FOR ENERGY WITH EMERGENCY LIGHTS. 1704 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32286	11041-10000-16213	815 W COLORADO BLVD # 200	90041	14	163-5A231 107	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.14051	-118.18382	TENANT IMPROVEMENT OF EXISTING 2ND FLOOR OFFICE SPACE (8908 SQ.FT.) OF EXISTING 6 STORY MIXED USE BUILDING. PLAN CHK IS FOR TITLE 24PERMIT FEE IS IN INSPECTION FEE SCHEDULE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32287	11041-10000-12453	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	07/05/2011 12:00:00 AM	ADDRESS	34.07666	-118.3805	TI TO AN EXISTING RESEARCH TEST LAB AT CEDARS SINAI.  PLAN CHECK IS FOR ENERGY ONLY, OTC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32288	15041-20000-10572	4554 N SHERMAN OAKS AVE	91403	5	168B145   983	2283023002	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM			Corrections Issued	04/09/2015 12:00:00 AM	ADDRESS	34.15345	-118.46892	600A SERVICE UPGRADE. THIS IS FOR CORE AND SHELL. TI UNDER SEPARATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32289	19041-10000-29936	550 S HOPE ST 4th fl	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	new luminaires and lighting circuits for elevator lobby, corridor, and restroomsplan check is for title 24 and 1 ea emergency ckt	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
32290	15041-10000-37216	7118 W GREELEY ST	91042	7	202-5A201 372	2568014016	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.24888	-118.28667	PV1, 5.00KW AC roof mounted system with (21) Q Pro BFR-G4 modules, and (1) Solaredge SE5000A inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32291	14041-20000-18268	18789 W MAPLEWOOD LANE	91326	12	207B121   776	2728031057	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.26046	-118.54271	PV1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32292	12041-20000-06923	639 N LARCHMONT BLVD STE 102-103	90004	4	141B189   437	5523012027	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.08288	-118.32397	Title 24 Energy Only for outdoor lighting. Outdoor patio for a restaurant. 310 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32293	15041-10001-08087	1635 W CARSON ST	90501	15	051B193   901	7349033025	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	33.83164	-118.30768	Changes to approved set.  Additional service and service equipment.  Delta-6 changes only.  (((SERVICE UPGRADE TO 600 AMPS.  PLAN CHECK FOR POWER ONLY. ALL PANELS AND LOADS ARE EXISTING.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32294	10041-10000-11723	1307 N VERMONT AVE	90027	13	147B197  1019	5543014013	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/18/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	ADDRESS	34.09594	-118.29206	"T. I. - DENTAL OFFICE. (CEC ART. 517) (CONVERT PORTION  21'  11""  X  25'  11""   OF RETAIL SPACE TO MEDINCAL (DENTAL) OFFICE  (572 SQ FT)) LTG Forms not submitted.   Ref.#10042-10000-13007."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32295	13041-10000-25859	5510 S LINCOLN BLVD 4TH FLR	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	12/26/2013 12:00:00 AM	ADDRESS	33.97299	-118.43051	TENANT IMPROVEMENT ON 4TH FLOOR. CONNECTED LOAD IS GREATER THAN 400A. PLAN CHECK IS FOR POWER AND ENERGY.  (1) 50KVA UPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32296	16041-10000-10865	12771 W JUDD ST	91331	7	213B161  1019	2533029080	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.2781	-118.41128	PV1, INSTALL 5.035 KW DC ROOF-MOUNTED SOLAR ARRAY ON ASINGLE FAMILY HOUSE.(19) MODULES: SOLAR CITY STANDARD 265W; 238.2W (1) INVERTER: SOLAREDGE SE3800A-US-ZB-USE P-300 IS USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32297	19041-20000-22175	22135 W ROSCOE BLVD LOT #15	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 15.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32298	16041-10000-05089	14508 W TYLER ST	91342	7	225B149   236	2504014025	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.31398	-118.44883	PV 1 roof mounted solar installtion with a central inverter rated at 5 kw, 22 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32299	10041-10000-16869	1333 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05086	-118.22436	Solar voltaic system installed on the roof of the building.  Consists of  12  modules, 12  A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32300	10041-10000-23511	601 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Closed	05/17/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY  ( 2-DAYS ) STANDBY GENERATOR  TO SUPPLY POWER TO EACH OF TWO MCC WHICH POWERS EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32301	18041-20000-21256	11850 N BALBOA BLVD	91344	12	216B133   474	2610002048	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.2854	-118.50127	TI to (E) coffee shop.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32302	10041-10000-00096	1512-1540 S CALZONA ST	90023	14	117A227    73	5192002012	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM	01/05/2010 12:00:00 AM		Permit Finaled	03/18/2010 12:00:00 AM	ADDRESS	34.01537	-118.19633	New sprinkler monitoring system for an existing building.  The FACP is in 1520 Calzona and the Annunciator is in 1540 Calzona.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32303	15041-20000-01988	17510 W MAYALL ST	91325	12	204B129   405	2734017002	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.25382	-118.51619	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZED 6.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32304	15041-10000-30657	800 E 4TH ST	90013	14	127-5A215 253	5163025001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Expired	06/19/2018 12:00:00 AM	ADDRESS	34.04322	-118.23729	CHANGE OF USE FROM WHAREHOUSE TO RETAIL ; plan check for new service, swbd, house panel and alterations in the common area; tenants will develope their individual space	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32305	16041-20000-10970	11560 N CRANSTON AVE	91342	7	213B169   512	2530026005	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.2806	-118.38524	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32306	16041-10000-20627	4929 N VAN NUYS BLVD	91403	4	169-5A151  49	2263026034	C1.5-1VL-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.16026	-118.4489	INSTALL (2) NEW NATURAL GAS FUEL CELLS IN A HOSPITAL BUILD. (OSHPD 3). FUEL CELLS LOCATED OUTSIDE OF BUILD. AND INTERCONNECTS WITH ELECTRICAL EQUIPMENTS LOCATED INSIDE THE BUILD. PC TO INQUIRE MANUFACTURE DATASHEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32307	18041-10000-08403	3670 S TROUSDALE PKWY BRI BLDG	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			PC Info Complete	09/06/2018 12:00:00 AM	ADDRESS	34.01868	-118.28606	INSTALLATION OF UNIT SUBSTATION 4.8KV/ 480/277 1290KVA  TO SUPPLY BRI BUILDING AND FUTURE LOADS ACC BUILDING AND COFFEE SHOP ; BRI BUILDING HAS NEW SWITCHBOARD DBHSB 1200A, 480/277V, 3PH,4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32308	19041-10000-22676	5711 W CENTURY BLVD	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	33.94573	-118.38128	ENERGY PLAN CHECK FOR A REMODELED PUBLIC RESTROOMS (4 SETS), REMODEL BAR & LOUNGE, REMODELED GRAND STAIRS & LOWER LOBBY STAIR CASE LOCATED IN A HIGH RISE BUILDING, WITH NEW LIGHTING; TOTAL LIGHTING AREA IS 7,112-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32309	16041-30001-44120	6101 N SHIRLEY AVE	91356	3	177B117   512	2153028032	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.18105	-118.55804	Expedited per applicant request.Plan check for a Pv1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverter, (35) modules, (1) load center, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32310	17041-10000-33149	6128 W WILSHIRE BLVD	90048	5	135B177   516	5088002035	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.06291	-118.36257	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 15650 SQ.FT (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32311	09041-10001-24398	5500 W SUNSET BLVD	90028	13	147A193   108	5544029011	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.09793	-118.30958	CHANGES TO APPROVED SET OF PLANS. T24 HAS BEEN CHANGED. DWP HAS UPGRADED TRANSFORMER. SOME CHANGES TO BRANCH CIRCUITS. LIST OF CHANGES AND APPROVED SET ATTACHEDCONSTRUCTION OF NEW 3 STORY RETAIL BUILDING AND PARKING AREAS ( TARGET STORE )VARIANCE HAS BEEN SUBMITTED TO SEPARATE THE FA PLANSCOMPLY WITHDEPARTMENT ORDER effective date 04/19/2011. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE. All permits shall be for the same timeperiod limitation. If additional assistance is needed, pleasecall Inspector BEN MATHIAS at (213)252-3959.  CEIS Case Number is413764.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32312	14041-10002-28440	533 W 5TH ST LEVEL 54	90731	15	015B197   205	7451028039	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Expired	05/30/2017 12:00:00 AM	ADDRESS	33.73956	-118.28867	Changes to approved set.  Change of lighting fixtures and updated Title 24 Part 6 calculations.  (((PLANCHECK FOR  ENERGY ONLY. TENANT IMPROVEMENT FOR US BANK BUILDING. PLANCHECK PER APPLICANTS REQUEST. LEVEL  54.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32313	16041-10003-35625	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	PIN	33.94094587	-118.40577128	03-29-2018 Changes to an approved set of plan. Changes include additional of 2 panels and associated circuits and equipment. Changes apply to clouded area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32314	13041-10000-12269	1900 S AVENUE OF THE STARS FLOOR 28	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/13/2013 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI for 28th story of a highrise office bldg.  Power and energy.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32315	19041-10001-01689	6340 W DREXEL AVE	90048	5	135B177   148	5510009026	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.06863	-118.36588	SUPPLEMENTAL FOR EXPEDITE FEEPC FOR ROOF MOUNTED 11.4 KVA PV SYSTEM. SYSTEM CONSITS OF 2 CENTRAL INVERTERS(SE3000H-US & SE7600H-US) WITH 35 MODULES USING P400 OPTIMIZERS  INCLUDING  2 ENERGY STORAGE SYSTEMS LG 9G CHEM 9.8KWH. 1 LOAD CENTER, AND AUTO TRANSFORMER, WITH RELOCATION OF LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32316	12041-10000-01456	11811 W DARLINGTON AVE	90049	11	129B145   313	4265017032	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			01/20/2012 12:00:00 AM	02/25/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.05105	-118.46642	PLAN CHECK POWER AND ENERGY FOR NEW 26 UNITS APARTMENT BULDING. 4 STORY + 1 LEVEL OF GARAGE.  1600A SERVICE. VARIANCE FOR THE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32317	16041-20000-12444	13803 W FOOTHILL BLVD 201-207	91342	7	225B153   381	2509002037	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.31046	-118.43385	Plan check for power and energy. Project site is the 2nd floor of an existing commercial building. Project scope is a change of use from medical office to office/tenant improvement. Total lighting area = 11,000 sq. ft. Note: Building application has been generated under 16016-20000-08201	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32318	19041-10000-00183	1053 S ORLANDO AVE	90035	5	132B173   596	5087006012	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	04/27/2019 12:00:00 AM	ADDRESS	34.05771	-118.37399	PC FOR NEW 10KW AC SFD ROOFTOP SOLAR SYSTEM AND A  ENERGY STORAGE SYSTEM. SCOPE OF WORK INCLUDES (1) 200A LOAD CENTER, (36) 325W DC PV PANELS, (1) 10KW SE10000A INVERTER, AND (2) 5KW TESLA POWERWALL BATTERIES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32319	19041-20000-18246	14922 W LA VALLE ST	91342	7	225B149   407	2505029015	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.31073	-118.4573	PV1.  Install 3.25 kW grid tied roof mounted PV system.  (10) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32320	15041-20000-27086	3233 W VERNON AVE	90008	10	111B185    80	5023010800	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.00377	-118.32907	PLANCHECK FOR POWER. INSTALLATION OF A 2000AMP TAP BOX BOARD FOR PORTABLE STANDBY GENERATOR AND OTHER FILTER CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32321	18041-20000-42038	5808 W SUNSET BLVD 6TH FLOOR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check for Title 24 only in existing high-rise space office T.I. partial 6th Floor. Total area: 7,191 sq ft. B#18016-10000-34590	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32322	16041-20000-14338	3250 W SAN FERNANDO ROAD BLDG 1	90065	13	153B209   283	5458002017	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.1172	-118.24859	TI TO AN EXISTING COMMECIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 31912.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32323	19041-20000-10314	20736 W BEECH CIR #306	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.29335	-118.58554	INSTALLATION OF A 3.02KW DC/2.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (9) SUNPOWER 335 BLK PV MODULES WITH INTEGRATED MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32324	18041-20000-02804	4800 S ALLA ROAD	90066	11	105B157   536	4223008005	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	33.98292	-118.42948	Permit 2 of 3 for (3) new 2-story core and shell commercial office buildings.  Building 2 distribution equipment/loads.  Plan check for power and energy.  Bldg permits for the (3) separate buildings are under the following permits:16010-10000-0393516010-10000-0393616010-10000-03937	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32325	16041-10000-25358	649 W ADAMS BLVD	90007	1	123A203   204	5124026013	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.02895	-118.27743	PC for energy only to offices in a school building. Adding new lighting and power. Total sqft = 3799.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32326	18041-10000-31731	100 WORLD WAY T1-64	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	Energy plan check for sign lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32327	16041-20000-34264	11708 W BARRINGTON CT	90049	11	135B145   646	4401007018	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.06422	-118.46948	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MILK RETAIL STORE. 1156 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32328	18041-10000-29083	125 W 4TH ST UNIT #101	90013	14	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.0488	-118.24807	TITLE 24 - ENERGY ONLY IN UNIT # 101 ON THE 1ST FLOOR UNDER CORE & SHELL.ORIGINAL PERMIT UNDER 15041-10000-10619THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32329	19041-10000-19743	1481 E 4TH ST	90033	14	127-5A219 301	5172020008	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.04276	-118.22443	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32330	16041-20002-41855	7277 N GLENHAVEN CT	91307	12	186B089   579	2027049025	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2017 12:00:00 AM			PC Approved	02/08/2017 12:00:00 AM	ADDRESS	34.20386	-118.64865	Revisions to approved plans.  Change from (E) main panel with derated main breaker rating to main panel upgrade.$0 plan check fee due to State Senate Bill SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32331	14041-10000-17727	6201 W HOLLYWOOD BLVD # 120	90028	13	148-5A189 350		[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	plan check for power and energy. BLDG#14014-10-02631:CHANGE OF USE FROM RETAIL TO RESTAURANT.  NEW 4050 SQ.FT. FULL SERVICE RESTAURANT IN EXISTING VACANT TENANT SPACE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32332	18041-20001-32856	4331 W ADAMS BLVD	90018	10	123B185   680	5059005031	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	34.03275	-118.33307	09-20-2018 Changes to an approved set of plans, Changes include update single line diagram. Changes has been clouded. plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32333	12041-20000-27544	3577 W BEVERLY GLEN TER	90077	5	159B149   192	2275024006	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00, 1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	PIN	34.13385033	-118.4533375	PV-1. Plan check for PV single family dwelling. 15.7kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32334	17041-10001-14624	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Issued	09/05/2017 12:00:00 AM	ADDRESS	34.23342	-118.3809	PC FOR T24 ENERGY ONLY. INSTALLING NEW 200A SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32335	16041-10001-10843	8338 W 3RD ST	90048	5	138B173   876	5511031030	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.07268	-118.37138	FULL PLAN CHECK FOR RESTAURANT TI. PLACE OF ASSEMBLY, GREATER THAN 100 OCCUPANT LOAD. PLAN CHECK FOR POWER AND ENERGY. ORIGINAL PERMIT WAS EXPRESS. THIS APPLICATION IS FOR PLAN CHECK ONLY. REUSING EXISTING 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32336	17041-20000-40728	5511 W THORNBURN ST	90045	11	102B173   437	4103009013	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			11/09/2017 12:00:00 AM	04/02/2018 12:00:00 AM		Issued	04/02/2018 12:00:00 AM	ADDRESS	33.97271	-118.3762	Plan check for power and energy. Project site is a new 34-unit apartment building. Work includes a new 1,600-amp service and a total lighting area of 41,549 sq. ft.Building permit # 17010-30000-01705.  Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32337	19041-20000-31074	181 S VERMONT AVE	90004	13	138B197  1240	5518030003	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2113.20	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.07061	-118.29189	INSTALL (5) NEW FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL AT COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32338	14041-20000-30594	13243 W TERRA BELLA ST	91331	7	204B157   570	2620019010	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.25626	-118.42147	Roof mounted PV system with tranformerless inverter.  Total system size 3.9KWNote: the solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32339	11041-20000-03948	11755 W WILSHIRE BLVD 1200	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	03/17/2011 12:00:00 AM	PIN	34.04869377	-118.46238681	Plan check T24 Energy for showroom in Suite #1200. Permit for new lighting on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32340	16041-10000-38122	1645-1717 S WESTERN AVE	90006	10	126B193   319	5073012031	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	34.0429	-118.30925	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW EXTERIOR LIGHTS FOR EXISTING PARK LOT FOR AN EXISTING BUILDING. TOTAL AFFECTED AREA IS 205032 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32341	18041-20001-30156	4658 N LONGRIDGE AVE	91423	4	168B157   544	2360025021	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.15559	-118.42124	Expedited plan check fee.PV1.  Install 15.435 kW roof mounted grid tied PV system.  (49) modules with 7.6 and 5.0 kW rated string inverters.  System split between main house and detached structure.  Derating of main disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32342	18041-20000-36714	7035 N RESEDA BLVD	91335	3	183B125   454	2126008009	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.19872	-118.53624	pv2install roof mounted pv system sized 12KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32343	19041-20000-47636	18200 W BATHURST ST	91326	12	213B125   485	2870013050	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.27844	-118.53109	PV1.  Install 11.52 kW roof mounted grid tied PV system.  (32) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32344	17041-20000-31694	2967 N HOLLYRIDGE DR	90068	4	156A191    37	5583017001	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.12259	-118.3199	PV1.  Install 8.45 kW roof mounted grid tied PV system.  (26) modules with 7.6kW rated string inverter.  13.5 kWh backup energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32345	18041-30000-09228	2049 S CENTURY PARK EAST suite 200	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing high-rise building office T.I. Total area: 4,620 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32346	19041-20000-36647	6301 N GLADE AVE	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	06/03/2022 12:00:00 AM	ADDRESS	34.18461	-118.60788	PV2.  Plan check for Pv roof mounted system, PV system size: 23.925KW DC, 21.3KW AC CEC with 55 PV Modules and 2 inverters(14.4KW and 9.0KW)Note: This is 12 Buildings on 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32347	11041-10000-11319	6022 W AVION DR	90045	11	090B165    36	4129028900	M2-1	West Los Angeles				9800.28	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	33.94182	-118.39269	"TI IN AN EXISTING COMMERCIAL AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS IN THE ""AMERICAN EAGLE ROMOTE HOLD ROOM"". power and lighthing."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32348	17041-10001-02735	5750 S MESMER AVE	90230	11	105B165   299	4220015038	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	33.98373	-118.39868	SUPPLEMENTAL PERMIT TO 17041-10000-02735 TO ADD (14) LED CAN LIGHTS TO EXISTING CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32349	19041-10000-43248	19810 W VANOWEN ST	91306	3	180B113    55	2134003010	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Issued	10/23/2019 12:00:00 AM	ADDRESS	34.19365	-118.56469	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.55KWdc / 7.267KWac.(30)MODULES-HANWHA 285 WATT Q.PLUS BFR-G4.1-285(30)MICROINVERTERS- ENPHASE IQ7-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32350	15041-20000-02869	6633 N COLUMBUS AVE	91405	6	180B145   276	2235003018	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.19132	-118.46421	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (19) 275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32351	13041-10000-05937	123 S ROBERTSON BLVD	90048	5	138B169   433	4334001900	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.07462	-118.3839	T24 FOR EXISTING RETAIL SPACE. DOING CHANGES TO THE LIGHTING PLANS. 1034 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32352	19041-10000-28601	1632 N BELLEVUE AVE	90026	13	136-5A207  28	5404014900	OS-1XL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1975.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.07013	-118.26075	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32353	16041-10000-16348	1307 W 78TH ST	90044	8	099B197   328	6019005014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	33.9695	-118.29847	PV1 SFD TOTAL SYSTEM SIZE 3KW AC (PV1-3.0-OUTD) USING 11 MODULES (KU2606XPA, WITH NONSTANDARD PLAN. ADD TO (E) SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32354	14041-10001-02662	3666 S 6TH AVE	90018	10	120B189  1598	5044028015	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	ADDRESS	34.02094	-118.32345	Expedited RSES plan check per applicant request.{{PV1, Install 3.75 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel. Ungrounded system with power optimizers.(1) Transformerless inverter: SOLAREDGE SE3800-US-ZB-U.(15) Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32355	19041-10000-34002	1771 W BLAKE AVE BLDG 5	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Corrections Issued	10/02/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	5 OF 11. BLDG 5POWER PLAN CHECK FOR 800A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDINGS AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32356	15041-10000-35393	333 S HOPE ST 24th floor	90071	14	130-5A211   2	5151014031	C4-4D, R4(PV)	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	Energy plan check for an office (Bank of America) TI located in an existing 24th floor of a high rise  building . Adding new offices to existing space. Scope includes new lighting and receptacles only. PC for energy only. Sq ft = 3017.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32357	13041-10000-04645	22786 W CASS AVE	91364	3	168B097   199	2076002028	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	34.15911	-118.62216	photovoltaic system for single family dwelling. total system size 4.56kw. 19 MODULES. CENTRAL TRANSOFRMERLESS INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32358	19041-10000-46155	1625 N SCHRADER BLVD	90028	13	148-5A187 241	5547015029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Info Complete	03/02/2020 12:00:00 AM	ADDRESS	34.10046	-118.33259	FULL POWER & ENERGY PC.  EXISTING SERVICE 600Amp 208/120 3phase 4wire. AFFECTED AREA 5465sqft. CHANGE OF USE FROM OFFICES TO PRIMARY CARE CLINIC. THE PROJECT IS OSHPOD 3 REMODEL WITH NEW EXAM AND LAB ROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32359	18041-10001-00835	11201 N WHITE OAK AVE	91344	12	210B129   185	2711019013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.27409	-118.51991	expedite per applicant request.NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 50 MODULES (HANWHA Q-CELL. Q PEAK-G4.1 305), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS P320) WITH TWO CENTRAL INVERTERS (SOLAR EDGE SE6000H-USRGM) AND  (SOLAR EDGE SE7600H-USRGM) .  SYSTEM SIZE IS 15.25 KWdc AND 13.6 KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32360	12041-10001-18930	2710 W TEMPLE ST	90026	13	138A203   229	5156023911	PF-1XL	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.07287	-118.27623	03/04/2016 Changes to an approved set of plans. A performance meter has been added to the single line diagram. All changes have been clouded.*****Previous Work Description*****PV2. Plan check for new ground mounted 109.8 KW photovoltaic system for existing LAPD building. Inverter located on lower level.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32361	17041-20001-39719	2587 N HUTTON DR	90210	5	153B157    60	4382010005	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.11884	-118.43191	06-07-2018 Changes to an approved set of plan. Changes include additional AC disconnecting mean to Energy Storage System. all changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32362	14041-10001-12529	14629 W HAMLIN ST	91411	6	180B149   566	2236014018	R1-1-HPOZ	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM			PC Approved	07/15/2014 12:00:00 AM	ADDRESS	34.18884	-118.4519	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 8.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER WITH OPTIMIZERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32363	19041-10000-41932	621 W 152ND ST	90247	15	072B201    75	6120001017	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	33.89472	-118.28668	POWER PLAN CHECK PER ENGINEER REQUEST TO INSTALL A NEW MATERIAL HANDLER CONNECTED TO AN EXISTING 2000A SERVICE. TOTAL NEW CONNECTED LOAD IS LESS THAN 400A. CONDUIT RUN IS IN A TRAFFIC RATED CHANNEL ABOVE GROUND. THE SITE IS A METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32364	13041-10000-05741	380 WORLD WAY space T71	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 6,092 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (III FORKS).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32365	19041-20000-02259	13323 W VENTURA BLVD	91423	4	165B157   792	2360011015	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.14688	-118.42332	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 591 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32366	16041-20000-24373	7359 N KESTER AVE	91405	6	186B149   544	2221013005	RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.20449	-118.45765	Plan check for fire alarm system. 1 FACP with 1 fire alarm device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32367	11041-20000-04687	2000 S AVENUE OF THE STARS P1	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM	05/02/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	Install new equipment, panels, and branch circuits for EV chargers. Parking includes 2029/2049 Century Park.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32368	17041-20000-25138	6907 N BALCOM AVE	91335	3	183B129   804	2122004007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.19582	-118.52074	PV1.  Install roof mounted PV system sized 3 kW interconnected with MSP.    This is an addition to an existing system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32369	13041-10000-21149	12652 W VILLAGE LANE bldg #4	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32370	11041-20000-21450	1888 S CENTURY PARK EAST 15th floor	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.06104	-118.41402	T.I.  Installing wall sconces to the corridor on the 15th floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32371	18041-20000-48955	2090 S WESTWOOD BLVD	90025	5	129B153  1124	4321014035	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.04549	-118.43291	PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO MEDICAL CLINIC. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING 600A DISTRIBUTION SYSTEM ADDING NEW 100AMP PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32372	10041-10002-23683	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		1390.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.18088	-118.48309	NEW MV DUCITBANKS, RELOCATED MANHOLES AND NEW CIRCUITS IN ORDER TO COMPLETE PROJECT TO PROVIDE NEW OVERFLOW TANKS)))))DISCONNECT THE EXISTING 4160V, 3PHASE FEEDERS TO THE EXISTING 2MVA TRANSFORMER (US-102) AND INSTALL NEW 750MCM FEEDERS TO CONNECT THE SAME TRANSFORMER TO A NEW LOCATION (BAY 2-9)((((((( 7-19-12   feeder cable changed , pull calculation , medium voltage)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32373	15041-20000-21213	10400 W WILSHIRE BLVD	90024	5	135B157   182	4327001012	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.0666	-118.42904	Title 24 plan check only.  Total area = 1,756 sq. ft.  T.I. to existing classroom space.  New lighting and recepticles in science lab.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32374	18041-10002-09351	532-536 S BROADWAY	90013	14	129A211   132	5149035004	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Issued	10/29/2019 12:00:00 AM	ADDRESS	34.04722	-118.25124	"DELTA ""1"" CHANGES TO APPROVED PLANS. SERVICE UPGRADE FROM 600AMP TO 800AMP. RECONNECTING TO EXISTING LOADS. NO NEW LOAD WERE ADDED. <<<FULL PLAN CHECK FOR A EXISTING HIGH RISE BUILDING UPGRADE.  SCOPE INCLUDES A NEW 600 AMP SERVICE, NEW BACK UP GENERATOR, PANELS AND CIRCUITS WITH NEW LOAD CALCULATION. TOTAL AREA IS 23,778 SQ FT.>>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32375	13041-20000-28615	8480 W HILLSIDE AVE	90069	4	148-5A173 303	5558028006	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.10114	-118.37318	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.5 KW AC USING 21 MODULES. USING ENPHASE MICROINVERTERS. NONSTANDARD PLNA. 2 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32376	13041-10001-09939	1439 N POINSETTIA PL 1-39	90046	4	147B181   777	5548019023	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			02/21/2014 12:00:00 AM			PC Info Complete	02/21/2014 12:00:00 AM	ADDRESS	34.09717	-118.34858	FULL PLAN CHECK FOR POWER AND ENERGY ON A 39 UNIT APARTMENT. 1600 AMP SERVICE.  1 TYPICAL UNIT PANEL. NOTE TO PLAN CHECKER: FIRE ALARM VARIANCE WILL BE FILED AT A LATER DATE, PHOTOMETRICS AND TITLE 24 CALCULATIONS WILL BE PROVIDED AT A LATER DATE CONTACT EMAIL .(((((((((((((((((((   changing bedroom ckts  in the bedroom unit 3 ckts  wires changed from # 12 awg to # 14 awg and ckts brkers from 20 to 15 amps not in the bath rooms.  2-21-2014 medi zandi)))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32377	15041-10000-24201	2303 S FIGUEROA WAY	90007	1	123A203   162	5124028010	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.03049	-118.27509	NEW FIRE ALARM SYSTEM FOR A  PRIVATE SCHOOL WITH (69) FA DEVCSE, 2 COMMUNICATION PANLES, ONE CONTROL PANEL  AND ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32378	14041-20001-30218	5801-5835 N FIGUEROA ST	90042	1	151-5A229 122	5492012025	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.11031	-118.19186	EXPEDITE PER CUSTOMER REQUESTPV2 INSTALL ROOF MOUNTED PV SYSTEM SIZED 125KW INTERCONNECTED WITH MAIN SERVICE PANEL. (576) SOLAR WORLD SW280 MODULES(2) SOLECTRIA RENEWABLES INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32379	14041-20000-33339	6850 N SEPULVEDA BLVD	91405	6	183B145   632	2220020012	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.19538	-118.46594	TI TO AN EXISTING TWO STORY MEDICAL FACILITY. RELOCATE EXISTING LIGHTING CONTROLS. ADDING CIRCUITS TO EXISTING PANELBOARD. EXISTING SERVICE. LIGHTING FIXTURES NOT TOUCHED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32380	15041-20000-22578	7602 COURAGE WAY	91405	6	186B145  1159			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20871518	-118.46419288	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32381	17041-20000-45252	14024 W FILMORE ST	91331	6	204B153   175	2617004044	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Issued	01/04/2018 12:00:00 AM	ADDRESS	34.25881	-118.43911	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.05KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32382	16041-10000-42759	829 N MARTEL AVE	90046	5	141B181   120	5526005006	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	05/30/2017 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.0861	-118.35131	Full plan check to a new 3 story 5 unit apt plus suptarranean parking level. New service 600 Amps 120/240 1phase 3wire. 3 typical units. Total sqft = 4882. Contractor to verify that all panelboard terminals are rated at 75 deg celcius.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32383	19041-20000-41462	2449 E HUNTER ST	90021	14	121-5A217 148	5168031025	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.02772	-118.22821	T24 PLAN CHECK FOR TI REMODEL OF (3) EXISTING COMMERCIAL WAREHOUSE UNITS. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 16303 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32384	13041-20000-34040	18293 W KAREN DR	91356	3	165B125    63	2184012005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.15229	-118.53096	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.45KWAC. 16 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32385	16041-20001-06278	20324 W VIA MEDICI	91326	12	219B113   127	2701045008	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.29431	-118.57691	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a SFD. Interconnect with a 300A MSP.System size: 12kW (6+6). Ungrounded system. (52) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32386	15041-20000-24423	738 S CROCKER ST	90021	14	126A213   437	5146032037	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.03906	-118.24679	THIS PERMIT IS PART OF 3 UNITS. THIS IS FOR PERMIT 738 CROCKER PLAN CHECKED AND APPROVED UNDER 15041-20000-01570.   OTHER UNITS UNDER SEPARATE PERMITS.	N	N	Express Permit	06/10/2024 12:00:00 AM
32387	12041-10000-28720	1555 N GORDON ST	90028	13	148-5A191 299	5545007019	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			11/29/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.09966	-118.31978	SUPPLEMENTAL PERMIT FOR A FIRE ALARM PANEL.ORIGINAL PERMIT IS UNDER PERMIT NUMBER 12041-10000-16869New Fire Alarm system for a new apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32388	17041-10000-04733	1025 S BERENDO ST	90006	1	129B197   336	5078012005	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			02/13/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.05197	-118.29388	NEW 5 STORY, 44 UNIT APARTMENT. PC FOR POWER AND ENERGY.  ((B# 16010-10000-04698))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32389	14041-10000-35068	1311 W SEPULVEDA BLVD	90501	15	045B193   791	7347018097	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			12/18/2014 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	33.81492	-118.30044	PC FOR POWER AND ENERGY FOR A NEW 6 STORY 176 UNITS APARTMENT BUILDING. TOTAL AREA 106800 SQ FT. B# 140410-10000-02205	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32390	15041-10000-26874	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.27455	-118.56289	NEW FIRE ALARM SYSTEM 130 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32391	16041-20000-03328	7400 N JORDAN AVE	91303	3	186B105   559	2111009018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.2051	-118.60274	Plan check for Title 24 only for bathrooms in existing space. Total area: 479 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32392	19041-10000-39528	15500 W ROSCOE BLVD	91406	6	192B145   438	2654038047	[T][Q]CM-1VL	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.22124	-118.4705	ENERGY PC ONLY FOR TEMPORARY SHOWROOM TENT STRUCTURE AND RESTROOM TRAILER. AREA OF SCOPE 7273SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32393	19041-10000-12807	4110 S LINCOLN BLVD	90292	11	108B153  1269	4230001002	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	33.98811	-118.44533	Remove HID fixtures and replace with new LED fixtures (Indoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32394	18041-10000-35866	4660 N LANKERSHIM BLVD	91602	2	168B173   751	2421025005	C2-1VL, R3-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.15542	-118.36867	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32395	15041-10000-36496	5231 W THORNBURN ST	90045	11	099B173   192	4103016011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	33.96917	-118.37115	PV1, INSTALL 6.625 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(25) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32396	15041-10000-18750	12491 W OSPREY LANE	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	33.97895	-118.41081	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'B'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'B' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32397	19041-10000-42372	1730 N WESTERN AVE	90027	13	148-5A193  68	5544007026	C4-1D, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	34.10267	-118.3091	Plan check for a new fire alarm system located in a commercial building. Scope includes (1) fire alarm panel, (1) power supply and (80) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32398	15041-20001-18516	19155 W VICTORY BLVD Bldg 4	91335	3	180B121   526	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	34.18675	-118.55116	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 4 kWac and consists of (1) inverter, and (20) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32399	18041-10000-48770	18953 W HARNETT ST	91326	12	207B121   705	2728016009	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.26129	-118.54666	PLAN CHECK FOR ROOFTOP MOUNTED 11.66 kw DC and 7.60KW AC PV SYSTEM WITH (37) MODULES , (1) AC INVERTER WITH 7.6 KW(SE7600H-US),  (1) POWER OPTIMIZER P320.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32400	18041-10000-15666	21301-21311 W VICTORY BLVD	91303	3	180B105    25	2148031016	WC	South Valley				1349.02	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.18858	-118.59682	NEW FIRE ALARM SYSTEM. 42 DEVICES, 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32401	18041-20001-43657	20308 W BALTAR ST	91306	3	189B113   352	2107009002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.21645	-118.57575	Revision to approved plans.  Addition of 9.8 kWh energy storage system to PV system.  (((PV1.  Install 7.6 kW roof mounted grid tied PV system.  (20) modules with 7.6 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32402	19041-20002-02412	8537 N LOUISE AVE	91325	12	192B133    58	2787025003	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.22589	-118.51	Changes to an approved set of plan, changes include point of PV connection to 400A, change from central inverter to microinverters System, addtion of 2 more PV Modules total new PV modules 51, update PV system size: 16.32KW DC, 13.87KW AC. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32403	17041-10000-04287	20310 W PLUMMER ST	91311	12	198B113    79	2748022075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.2426	-118.5759	PC for outdoor Title 24 only. Removing HID fixures and replacing them with new LED ones. Area: 49,060.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32404	16041-10000-42169	19400 S WESTERN AVE	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			PC Info Complete	12/01/2016 12:00:00 AM	ADDRESS	33.8552	-118.30917	PC FOR ENERGY. T.I. OFFICE, ONE STORY BUILDING, CONNECTED LOAD <400 A. TOTAL AREA 3260 SQ FT. B# 16016-10000-26226	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32405	16041-10000-28398	1522 N HIGHLAND AVE	90028	13	147A185    37	5547020040	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.0987	-118.33847	FULL PC FOR POWER AND ENERGY FOR  NEW 1 STORY EDUCATIONAL/DANCE STUDIO BUILDING. SCOPE INCLUDES 2000A 120/208 3 PHASE, 4 WIRE SERVICE, 3 NEW SUBPANELS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 8855 SQ. FT.  B#16010-10000-03518	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32406	14041-20002-13338	6919 N CASTLE PEAK DR	91307	12	183B085   115	2031010025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	34.19794	-118.66002	Modification to approved set.  Change of location of AC disconnect, both inverters, and load center to new location adjacent to main service panel.  $0 plan check fee is due to Senate Bill SB-1222(((PV1  INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.94KW INTERCONNECTED WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS SOLAREDGE SE 3800A(39) TRINA SOLAR MODULES TSM-PA05.18)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32407	16041-20000-09179	17541 W STRATHERN ST	91325	12	189B129   428	2201003025	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.21579	-118.51576	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (27) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32408	16041-10001-42204	834 W 30TH ST	90731	15	009B197  1349	7469010009	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			PC Approved	01/13/2017 12:00:00 AM	ADDRESS	33.71751	-118.29644	Expedited Fees. PV2 roof mounted solar system installation. Intalling a 3.0 KW central inverter with 8 solar modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32409	15041-10001-23206	19851 W NORDHOFF PL ste 104	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.23624	-118.56649	CORRECTION OF ADDRESS TO 19851 W. NORDHOFF PL STE 104.DEPARTMENT ERROR $0.00 FEE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32410	16041-20000-16893	13050 W CHANDLER BLVD	91401	4	171B161    98	2345020019	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	PIN	34.16806595	-118.41772298	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.2 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32411	15041-10001-30521	12700 W MILLENNIUM #15	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	33.97639	-118.41499	Expedite per applicant request(((PV1 4kW AC (AC MODULE) roof-mounted system with (16) modules and one load center interconnecting through the main service.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32412	15041-20000-03102	9825 N BALBOA BLVD	91325	12	201B133   204	2692012033	C2-1VL	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.24953	-118.50261	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR TACO BELL RESTAURANT.  13450 SQFT, INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32413	10041-10000-05907	5555 E VALLEY BLVD Bldg 325	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.07489	-118.16218	Addition of new panelboards, circuits, chillers  to a pharmaceutical manufacturing facility (Grifols Building 325).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32414	19041-10001-29545	12641 N BRADFORD PL	91344	12	219B129   442	2601061010	RE11-1-H, RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.29662	-118.52053	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.375KWdc / 14.186KWac CEC. (41)MODULES- 375W TSM-DE14A(11) PERC(41)OPTIMIZERS SOLAREDGE P400(1)INVERTER SOLAREDGE SE11400H-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32415	12041-10000-20718	4501 W COLORADO BLVD	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM			Plans on Hold	10/31/2012 12:00:00 AM	ADDRESS	34.14246	-118.2705	NEW FIVE STORY COMMERCIAL BUILDING.  BUILDING #B6 OF BAXTER CORP.  COMPLETE PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32416	10041-10000-17955	14130 W RIVERSIDE DR 1st Floor	91423	2	168B153   446	2248029009	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/10/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	10/06/2010 12:00:00 AM	ADDRESS	34.15674	-118.44089	"TI IN AN EXISTING OFFICE AREA ON THE 1ST FLOOR ""PRIORITY MAILING SYSTEM"". PLAN CHECK IS FOR T-24 ENERGY CALCS & EMERGENCY LIGHTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32417	15041-20000-14676	11825 W BURBANK BLVD	91607	2	174B169   815	2340036001	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.17231	-118.39076	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (21) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32418	16041-10001-40264	380 WORLD WAY SPACE T85	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			PC Approved	03/16/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to approved set of plans. Changes reflected under delta 1. Change in light fixtures manufactureer. Changes reflected on T-24. (7-Eleven).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32419	15041-20002-26271	22200 W SHERMAN WAY	91303	3	183B101   106	2024013189	C1-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			07/11/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.20073	-118.61062	"07-11-2016 Changes to an approved set of plans. Changes include additional dimmers control location on the floor plan and update the conduit type. Changes apply to delta ""C"" only. {{{{{{NEW RESTAURANT 800 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.}}}}}}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32420	11041-20000-07578	7608 N SEPULVEDA BLVD	91405	6	186B145   139	2209034030	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.20879	-118.466	Title 24 for outside parking.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32421	13041-10000-05745	380 WORLD WAY Space T22	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			Reviewed by Supervisor	04/02/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 1,052 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (James Beach).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32422	13041-20000-01253	11164 W COHASSET ST	91352	6	186B173   549	2315018035	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.2065	-118.37444	Photovoltaic system using enphase inverters on roof of carport and dwelling with PV subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32423	17041-10000-18105	7528 N RESEDA BLVD C	91335	3	186B125   294	2119017023	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.20741	-118.53586	REMOVE EXISTING HID FIXTURES AMD REPLACE WITH NEW HID FIXTURES - TOTAL OF 5 FIXTURES. SQ. FT. 6825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32424	16041-10001-10771	2611-2619 W EXPOSITION BLVD	90018	10	117B189    81	5044024046	[Q]CM-1VL-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM			PC Approved	09/07/2016 12:00:00 AM	ADDRESS	34.02044	-118.32406	PC FOR CHANGES TO APPROVED SET OF PLANS. REDUCTION OF SCOPE OF WORK. REMOVE DUCT DETECTORS FROM PLANS AND REMOVE AC UNITS NOTED ON ROOF PLAN. CHANGES TO FIXTURES UPDATED T24 DOCUMENTS.  ALL CHANGES CLOUDED DELTA 3 ON PLANS. NO OTHER CHANGES. PC ONLY. NO PERMIT NEEDED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32425	18041-10000-25420	326 S RENO ST	90057	1	136-5A201 238	5155009014	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Public Safety Only			07/09/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	01/15/2021 12:00:00 AM	ADDRESS	34.06744	-118.28363	PC FOR A NEW FIRE ALARM SYSTEM FOR A 5-STORY MULTI-RESIDENTIAL BUILDING. SCOPE INCLUDES INSALLATION OF 167 FA DEVICES, AND 8 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32426	18041-10002-04518	12918 W RUBENS AVE	90066	11	105B157   485	4223007023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM			PC Approved	07/10/2019 12:00:00 AM	ADDRESS	33.98447	-118.42877	Changes to approved set, all changes are under delta 2. Scope of work includes removing two AC disconnects and relocation of equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32427	15041-20000-31879	6303 N OWENSMOUTH AVE Level 1	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.18474	-118.60182	Plan check Title 24 only T.I. Farmer Insurance. Total area: 940 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32428	14041-10001-33747	12515 W OSPREY LANE 1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	33.97893	-118.41131	Modifications to approved set.  Minor revisions related to relocation of few devices, some omissions, etc. made per inspection comments.  (((Installation of (N) fire alarm system consisting of (50) initiating and notification devices in multifamily dwelling.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32429	16041-30000-35029	9649 N OWENSMOUTH AVE	91311	12	201B105   204	2746016018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.24558	-118.60253	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.  Total area = 8,316 sq. ft. (indoor) + 18,794 sq. ft. (outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32430	19041-10000-52790	5550 S INGLEWOOD BLVD	90230	11	105B165   410	4220016900	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	04/20/2022 12:00:00 AM		Permit Finaled	12/20/2023 12:00:00 AM	ADDRESS	33.98441	-118.40559	PLAN CHECK FOR POWER ONLY. SCOPE OF WORK INCLUDES A 480V POWER PANEL AND (2) 20HP CARBON SCRUBBERS CONNECTED TO AN EXISTING 600A (480/277) SWITCHBOARD. HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32431	13041-10001-16072	735 S FIGUEROA ST # 115	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	(((Addition of one oven and one fixed monopoint light 08/05/2013)))))First time tenant -The pizza studio	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32432	19041-10000-47341	5790 W JEFFERSON BLVD	90016	10	120B173   842	4205031012	[Q]M1-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	02/10/2020 12:00:00 AM		Permit Finaled	12/05/2023 12:00:00 AM	ADDRESS	34.02643	-118.37606	PLAN CHECK FIRE ALARM SYSTEM. SYSTEM INCLUDES 15 PANELS AND 720 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32433	11041-10000-23781												Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM			PC Approved	11/07/2011 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32434	16041-10000-43818	12134 W STAGG ST	91605	2	189B165   895	2307011012	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.21199	-118.39762	PC FOR PV SYSTEM WITH AC MODULES. TOTAL SYSTEM SIZE 11.7KW AC USING 34 MODULES. ROOF MOUNTED	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32435	16041-10000-10491	11800 W VENTURA BLVD	91604	2	162B169   323	2369027025	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.14185	-118.38938	FULL PC TO A TI IN A VETERINARY HOSPITAL. WORK BEING DONE IS ON THE  TO 2ND FLOOR AND A SMALL ADDITION TO 1ST FLOOR. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES, TOTAL CONNECTED LOAD IS > 400AMPS. NOTE: ENERGY PLAN CHECK FOR THE SECOND FLOOR; AND 1ST WAS APPROVED UNDER PERMIT NUMBER:   10041-20000-16153, PERMIT WAS FINALED WITHOUT FIRST FLOOR BEING COMPLETED. INSPECTION REQUESTED NEW STAMPED DRAWINGS. FINAL INSPECTION FEES SHALL INCLUDE UNFINISHED WORK IN THE FIRST FLOOR ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32436	19041-10000-09514	672 E BROOKS AVE 1/2	90291	11	111B145  1721	4239012051	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.99642	-118.46663	[ePlan] New rooftop  Roof Mounted PV System 5.2 kW AC with 1 Tesla Powerwall (13.5kWH Energy Storage System). (1) 5.2 kW inverter, (17) modules,  (1) 200A load center. System tie to (E) 200A service.(Parcel ID #111B145 1722)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32437	15041-20000-06531	4728 N LOUISE AVE	91316	5	168B133   371	2289010012	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			PC Info Complete	05/07/2015 12:00:00 AM	ADDRESS	34.15596	-118.50963	Plan check for the installation of a new service 800-amp service, (8) panels, (1) A/C unit, and (1) 180 kW generator.pc nly. sfd. permit issued from building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32438	10041-10000-25222	1033 N COLE AVE	90038	13	144B185   841	5533014901	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM			PC Info Complete	10/05/2011 12:00:00 AM	ADDRESS	34.08983	-118.33006	New one story customer payment center. EPC is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32439	14041-10000-17587	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Reviewed by Supervisor	08/22/2014 12:00:00 AM	ADDRESS	34.09818	-118.32309	IN A REFURBISHED BUILDING, TENANT IMPROVEMENT  ON ALL FLOORS. CORE AND SHELL ON SEPARATE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32440	14041-20002-02366	735 S FIGUEROA ST UNIT 139	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	change to lighting plan. no change in wattage calcs. recircuit emergency fixtures to allow normally on emergency fixtures to be connected to emergency panel. per design, inspector field verify use of 2 ballaste emergency fixtures. emergency ballaste shall be listed for emergency use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32441	14041-10000-08505	10433 W WILSHIRE BLVD 1-117	90024	5	135B157   180	4360029***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Apartment			04/01/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.06639	-118.43053	REPLACE EXISTING FIRE ALARM SYSTEM FOR HIGHRISE APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32442	16041-20000-04648	4542 N SYLMAR AVE	91423	4	168A151   189	2265016014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.15423	-118.44637	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (24) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32443	17041-10000-16627	1100 S GLENDON AVE 18th FL.-CORRIDOR	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.06074	-118.44418	PC FOR ENERGY. T.I. 18TH FLOOR CORRIDORE.  CONNECTED LOAD < 400AMP. TOTAL AREA 2086 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32444	19041-20000-21357	20700 W SESNON BLVD #177	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	Plan check for a PV1 roof-mounted PV system. System size is 5.25 kWdc/4.725 kWac and consists of (15) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32445	18041-20000-00648	18000 W DEVONSHIRE ST	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.25698	-118.52508	Plan check for Title 24 only. Project site is a suite on the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 368 sq. ft.Note: Building application has been generated under 18016-20000-00153	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32446	16041-10001-41752	752 E WASHINGTON BLVD	90021	9	121-5A209 195	5131006011	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM			PC Approved	03/08/2017 12:00:00 AM	ADDRESS	34.02678	-118.25595	Plan check for Title 24 only in existing space wearhouse T.I. lighting Total area: 4476 sq ft. Plan check only. Permit was pulled under 16041-20000-41752	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32447	18041-10000-31018	5927 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	33.93319	-118.38745	PLAN CHECK FOR TITLE 24 INLY FOR - TI TO EXISTING SECURITY SCREENING ROOM: DEMO/NEW PARTITION WALLS, NEW SUSPENDED CEILING, NEW FINISHES - TOTAL AFFECTED AREA = 1396 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32448	11041-20000-20733	12400 W BRANFORD ST	91352	6	201B165   117	2629001004	(T)(Q)M2-EZ1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1048.10, 1212.10	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.24795	-118.40337	PLAN CHECK POWER AND ENERGY FOR NEW FEDEX DISTRIBUTION WAREHOUSE AND GATEWAY BUILDING (12500 W BRANFORD ST.) WITH 4000A SERVICE. PERMIT FOR GATEWAY BUILDING UNDER #12041-10000-01804	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32449	10041-10001-24663	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Closed	11/08/2013 12:00:00 AM	ADDRESS	34.05373	-118.26606	TEMPORARY POWER FOR THE CONSTRUCTION OF A NEW 7 STORY MEDICAL OFFICE BUILDING. CORE & SHELL PLANS ARE PERMITTED ON APPLICATION # 10041-10000-24663	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32450	11041-20000-15575	11671 W VICTORY BLVD	91606	2	180B169  1107	2335010020	(T)(Q)RAS4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.01	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.18685	-118.38686	PLAN CHECK POWER AND ENERGY FOR NEW COIN OPERATED CAR WASH WITH 800A SERVICES. NEW SERVICE ALSO SUPPLIES EXISTING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32451	14041-10002-00531	900 S CRENSHAW BLVD	90019	4	132B189   914	5092003022	CR-1VL	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			02/18/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.05612	-118.32202	02/18/2016CHANGES TO AN APPROVED SET OF PLANS, SCOPE OF WORK INCLUDES THE CHANEGE FROM FULLY RATED TO SERIES RATED AND LAY OUT OF SINGLE LINE DIAGRAM TO MATCH THE FIELD. (((PLANS WERE REVISED TO SHOW THE USE OF ALUMINUM TYPE SE CONDUCTORS AS FEEDERS TO APARTMENTS PANELBOARDS AND ALUMINUM TPE THHWN AS FEEDERS  FOR HOUSE PANELS AND LOADS.; USE 15A BRANCH CIRCUITS FOR LIGHTING IN THE UNITS))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32452	14041-20000-23816	24016 W KITTRIDGE ST	91307	12	180B089   365	2034015006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.19113	-118.64956	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.87kW(18) EnPhase M215-IG micro inverters(18) SolarWorld Poly SW250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32453	16041-20000-05655	18630 W RUNNYMEDE ST	91335	3	186B121   586	2118009020	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	PIN	34.20539516	-118.53951123	Plan check for PV roof mounted system. System size: 5.0kW with 15 modules and 1 inverter(5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32454	17041-20000-43087	3430-3440 W SUNSET BLVD	90026	13	144A203   273	5427026007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	05/15/2018 12:00:00 AM		Issued	05/15/2018 12:00:00 AM	ADDRESS	34.08821	-118.27637	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE (E) 1 STORY OFFICE INTO 5 SPACES (4 retail & 1 restaurant).  BUILDING PERMIT: 17014-30000-02810	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32455	16041-10000-10412	1275 W 30TH ST	90007	9	120B197   297	5055010019	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.02754	-118.29099	3 STORY , 24 UNIT TYPE V-A  APT BUILDING  OVER ONE LEVEL  TYPE I-A PARKING GARAGE. PC FOR POWER AND ENERGY LOCATION IN METHANE ZONE.  TOTAL AREA 16832 SQ FT,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32456	14041-10002-19665	7751 W BEVERLY BLVD	90036	5	138B177   431	5527039001	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.07628	-118.3586	01/22/16Changes to an approved set of plans. All changes are made under delta 6.  Changes include feeder schedule revision, and AIC ratings for equipment.  PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE NEW 600A SERVICE AND ORIENTATION OF SERVICE EQUIPMENT. ALL CHANGES CLOUDED DELTA 5 REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32457	13041-20000-29270	3620 S VERMONT AVE 300-352	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.02213	-118.29133	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN OFFICES. LOCATED IN SUITE 300 AND 352	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32458	16041-10000-31885	13075 W VICTORY BLVD	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			Reviewed by Supervisor	09/22/2016 12:00:00 AM	ADDRESS	34.18684	-118.41708	REMODEL OF EXISTING BUILDING SPACE. CREATING SHELL OUT SPACE FOR FUTURE RESTAURANT. PROVIDING NEW SERVICE 800A AND FEW CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32459	15041-20001-10749	670 N SAN LORENZO ST	90402	11	124-5A133  19	4408035002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			PC Approved	04/16/2015 12:00:00 AM	ADDRESS	34.03694	-118.50938	Expedite per appliant request*******Plan check for PV1 roof mounted 8.0kW system and 16modules(SUNPOWER SPR-X21-345) with 1 inverter(SMA SB7700TL-US-22)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32460	19041-20001-25211	11914 N DARBY AVE	91326	12	216B121   231	2870007035	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.28941	-118.53981	expedited per customer request. PV1. 12.285 KW DC / 11.054 KW AC roofmountd system with (39) modules and micro inverter (IQ7 plus-72-x-US) interconnecting through a new load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32461	12041-10000-17511	15135 W GERMAIN ST	91345	7	207B145   475	2649005022	RA-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	09/14/2012 12:00:00 AM	ADDRESS	34.26226	-118.46209	Plan check for rooftop PV. 12.24kW. Single family dwelling.  Plan check is only for PV portion of job, not main panel and service upgrade.  Permit fees, including service upgrade, are under inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32462	19041-20000-50548	4450 W YOSEMITE WAY	90065	14	159A219    62	5684027003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.13156	-118.22471	PV1.  Install 7.56 kW roof mounted PV system and 27 kWh energy storage system.  (24) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32463	12041-10000-00858	500 S VIRGIL AVE #201	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM			PC Approved	01/13/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	T.I. to an existing Medical Office.  Changing lights, adding receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Suite #201 for a 4-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32464	18041-20000-08360	888 W 6TH ST Suite 700	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.05062	-118.25846	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 975 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32465	11041-10000-03846	8340 S LINCOLN BLVD	90045	11	096B157   267	4113016018	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	33.96181	-118.42071	TI.   TITLE 24 ONLY ON AN EXISTING GROCERY STORE.  PERMITS HAVE ALREADY BEEN PULLED, PER CONTRACTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32466	14041-10000-12717	12004 W VOSE ST	91605	2	183B165   203	2321008015	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.19833	-118.39453	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL  2541 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32467	16041-10000-16540	505 E 47TH ST	90011	9	112-5A207 332	5109016021	R2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.00082	-118.26622	PV1 roof-mounted 2.6KW AC system with (12 ) Canadian Solar modules and (12) Enphase M215 Microinverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32468	12041-20000-18182	10100 W SANTA MONICA BLVD VTC-2507	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Approved	08/16/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24 lighting plan check for conference room, VTC 2507.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32469	17041-10000-31456	10459 W TUXFORD ST #B	91352	7	198B177   137	2544014016	A1-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.23764	-118.35908	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL PROPERTY. SYSTEM SIZE 6KVA INVERTER(SUNNYBOY SNA 6.0-US) WITH 17 MODULES(LG 395N2W-A5)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32470	18041-20001-40089	16810 W MAGNOLIA BLVD	91436	5	171B133   367	2259002008	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM	ADDRESS	34.16481	-118.49948	11-02-2018 Changes to an apporved set of plan, Changes include update sub breaker size to 70A and 200 A load center. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32471	16041-10000-15717	10048 N ORION AVE	91345	7	204B145   820	2660005016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.25328	-118.47166	PV1 NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOFTOP. INCLUDES 5760W LOAD. INCLUDES 24 NEW MODULES AND 24 MICRO INVERTERS. STANDARD PLAN IS BEING USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32472	11041-20000-04278	6633 N FALLBROOK AVE Temp.-Generator	91307	3	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.19044	-118.62372	Plan check for 2000KW temporary generator and feeders power existing tenant spaces during repair.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32473	19041-20001-01569	10325 N GLENOAKS BLVD	91331	7	204B165    65	2537018034	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.25782	-118.39588	Expedited plan check fee.PV3.  Install 31.85 kW roof mounted grid tied PV system.  (98) modules with (3) 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32474	14041-10000-10270	3030 W OLYMPIC BLVD	90006	10	129B193   316	5080033029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.0524	-118.3013	TENANT IMPROVEMENT IN EXISTING BANKPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32475	17041-10001-02387	7965 1/2 W MELROSE AVE	90046	5	141B177   536	5527013004	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM			PC Approved	06/16/2017 12:00:00 AM	ADDRESS	34.08392	-118.36331	SUPP. Plan check ONLY for energy only change of use from retail to restaurant. New lighting and power. Area: 642DUE TO LOST SET PERMIT PULLED UNDER ORIGINAL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32476	17041-10000-13869	601 S LOS ANGELES ST 101-102	90014	14	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.04467	-118.24937	PC FOR ENERGY. T.I. CHANGE OF USE FROM RETAIL TO RESTAURANT.  NEW CONNECTED LOAD < 400 AMP. TOTAL AREA OF LIGHTING 1444 SQ FT.B # 17016-10000-10511	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32477	15041-10000-04474	11400 W OLYMPIC BLVD 830	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.03666	-118.44346	Tenant improvement of office space. T24 only. Total area = 1426 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32478	16041-20000-22662	9722 N CASABA AVE	91311	12	201B113   541	2748016035	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.24702	-118.57616	PV1.  Additon of (2) modules to (E) 6 kW PV roof mounted system, and relocation of (4) modules from (E) system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32479	10041-10000-16980	3616 S TROUSDALE PKWY Suite 127-& 230	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	07/05/2011 12:00:00 AM	ADDRESS	34.01983	-118.28534	T-24 lighting plan check only for remodeled office and labs in the allen hancock foundation building, suite 127 and 230.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32480	18041-20001-34141	15950 W SKYTOP ROAD	91436	5	162B141   209	2286016001	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	34.14066	-118.48088	Expedited plan check fee. PV1.  Install 20.46 kW roof mounted grid tied PV system.  (62) modules with (2) 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32481	17041-10000-25117	5412 W MONROE ST	90038	13	141B193   250	5535013011	R2-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.08565	-118.31181	Plan check for roof mounted PV system - scope includes 3.6KVA system consisting of 1 inverter (ABB 3.6-S-US), and 15 modules (trinamount)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32482	19041-10000-31816	5995 N TOPANGA CANYON BLVD	91367	3	177B101   178	2146006013	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.17881	-118.60557	Replace fluorescent troffers with new LED retrofit kits -  Indoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32483	10041-30000-10544	1901 S AVENUE OF THE STARS SUITE 935	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM			PC Approved	06/03/2010 12:00:00 AM	ADDRESS	34.05949	-118.41705	LIGHTING IN OFFICE AREA SUITE 935. EXISTING PERMIT # 10041- 90000-10438.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32484	13041-20001-12990	424 N CRESCENT HEIGHTS BLVD	90048	5	141B177  1393	5514006035	R1-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2013 12:00:00 AM			PC Approved	07/29/2013 12:00:00 AM	ADDRESS	34.07893	-118.36571	Mod to approved plans to change roof layout.  Plan Check Only.      <<<<New Ungrounded Rooftop PV system for an existing single family residence.  Site is in a methane zone.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32485	18041-20000-28706	10019 GLORY AVE	91042	7	202-5A201 182	2568002045	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	PIN	34.25043288	-118.28149087	Plan check for PV roof mounted system, system size: 3.8kW with 16 pv modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32486	17041-20001-46515	20041 W NORTHRIDGE ROAD	91311	12	207B113   146	2708020017	RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	01/02/2018 12:00:00 AM	ADDRESS	34.26228	-118.56963	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.173 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32487	17041-20000-35820	10828 W PEACH GROVE ST	91601	2	168B173   302	2421013007	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.1589	-118.36682	ENERGY STORAGE SYSTEM + PV1 ROOFMOUNTED PV SYSTEM. SYSTEM SIZE: 3.8 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32488	11041-20000-15012	26640 S WESTERN AVE UNIT E	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	33.78015	-118.30862	T24 ENERGY FOR NEW BAKERY SPACE IN EXISTING FRESH & EASY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32489	13041-10000-28411	108 E 5TH ST 1-69	90013	14	129A211   194	5148019011	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Closed	07/03/2014 12:00:00 AM	ADDRESS	34.04636	-118.2484	TEMPORARY POWER: 600A EQUIPMENT. NOT METHANE. 6STORIES -POSSIBLE HIRISe. manlift and 4 power for spider boxes	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32490	16041-10000-37844	14804 W RAYMER ST	91405	6	189B149   535	2210025033	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.2127	-118.45556	PC FOR NEW 7.5 HP MOTOR TO PRESUURIZE 2 FUEL DISPENSERS. INSTALLING 2 STORAGE TANKS. PC FOR HAZARDOUS AREAS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32491	13041-10000-14238	3550 S TROUSDALE PKWY	90089	9	118-5A201   9	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	34.02094	-118.28463	Outdoor lighting for walkway and landscape lighting at USC.  New fountain pump.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32492	17041-10000-36852	4322 S CENTRAL AVE	90011	9	114A209   338	5115033039	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.00518	-118.25582	REPLACE OUTDOOR HID EXISTING FIXURE WITH NEW LED FIXURE - TITLE 24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32493	17041-10000-23338	11401 N PORTER RANCH DR BLDG 2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	03/05/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 2 of 10.  Type I.       Building permit #17010-10000-02378	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32494	14041-20000-10064	17928 W STRATHERN ST	91335	12	189B129   461	2101028010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.21555	-118.52389	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.6KW AC USING MICROINVERTERS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32495	16041-20000-37420	6840 N DE CELIS PL #28	91406	6	183B137   536	2225001***	[T][Q]RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.19497	-118.4944	pv1install pv system sized 3kw interconnected with msp.This is an additional system to an existing 3kw.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32496	15041-10000-05297	2905 E 11TH ST	90023	14	120A221   174	5170025014	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Expired	03/21/2017 12:00:00 AM	ADDRESS	34.02163	-118.2158	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACEMENT OF EXISTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2912.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32497	11041-20000-25180	8014 W MELROSE AVE	90048	5	141B177   616	5527015004	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM			Corrections Issued	11/23/2011 12:00:00 AM	PIN	34.0835083	-118.3643449	T-24 lighting plan check for remodeled tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32498	19041-10000-49178	1128 S SHENANDOAH ST 1-6	90035	5	132B169   615	4332019006	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	04/25/2024 12:00:00 AM	ADDRESS	34.05632	-118.38136	PLAN CHECK FOR FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES 1 FA PANEL AND 53 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32499	17041-10003-02863	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM			PC Approved	06/26/2018 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGED ON LEVEL 2 APRON, ZONE M19 STORAGE AREA SPACE 285 AND 290.SCOPE INCLUDES CHANGE TO LIGHT FIXTURE TYPE AND REVISIONS TO TITLE 24 FORMS TO REFLECT THE CHANGE. THIS IS PLAN CHECK ONLY!!!PRMIT PAID UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32500	17041-30000-21180	14822 W MAGNOLIA BLVD	91403	4	171A149    18	2263038085	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.1647	-118.45604	Plan check for a fire alarm system for a condo building. Fire alarm system consists of (1) FACP and (21) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32501	19041-10000-47439	106 N KINGSLEY DR	90004	10	138B193   900	5517022028	R1-1	Central	Wilshire	Wilshire Center-Koreatown		2114.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.07402	-118.30279	(E-PLAN)NEW PV1  ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 18 MODULES (PANASONIC 330), 18 MICROINVERTERS (ENPHASE IQ7X), 1 SUBPANEL OF 125 AMPS, AND 1 ENERGY STORAGE SYSTEM. SYSTEM SIZE: 5.94 KW DC; 5.67 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32502	14041-20000-25522	17635 W TULSA ST	91344	12	210B129   740	2712013002	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.26867	-118.5188	PV1CENTRAL TRANSFORMERLESS INVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32503	14041-20001-17297	6430 W SUNSET BLVD 7TH FLR	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	Modifications to approved set.  Addition of 530 sq. ft.  PC FOR T24 ENERGY ONLY. NEW LIGHTING. EXISTING OFFICES. PERMIT ISSUED UNDER THIS APPLICATION. WORK DONE IN 7TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32504	11041-20000-09851	7248 N FULTON AVE	91605	2	186B157   583	2327002015	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.2026	-118.42239	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR CHG OF USE FROM MANUFACTURING  TO MUSIC STUDIO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32505	17041-20000-40182	12190 W VENTURA BLVD	91604	2	162B165   207	2369004042	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.14304	-118.3982	Tenant improvement to (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32506	16041-20000-19799	12950 W PIERCE ST	91331	7	207B161   165	2536016014	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.26561	-118.41533	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR VIDEO EQUIPMENT RENTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32507	18041-20002-28313	20751 W MARILLA ST	91311	12	201B109   151	2748004043	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM			PC Approved	04/25/2019 12:00:00 AM	ADDRESS	34.24825	-118.58596	4/25/2019plan check for power.  addition of (2) transformers and (1) panel, changing feeder fron CU to AL. all changes noted delta A.this is plan check only.Permit fees paid under application number 18041-20000-28313((((ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  Plan check for indoor energy only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32508	19041-10000-44399	14153 W GREENLEAF ST	91423	4	165B153   671	2266004003	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM			Ready to Issue	03/31/2020 12:00:00 AM	ADDRESS	34.14726	-118.44174	POWER PLAN CHECK FOR SINGLE FAMILY DWELLING. INCLUDES 1200A SERVICE, 120/208V, WITH 1 BACKUP GENERATOR, 9 PANELS AND OTHER ASSOCIATED EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32509	15041-10000-07406	5627-5635 N FIGUEROA ST	90042	1	151-5A229 230	5468033021	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.10951	-118.19345	SERVICE UPGRADE TO 800 AMP,  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32510	17041-10000-42243	3115 W 3RD ST	90020	13	136-5A201 127	5501019001	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			11/21/2017 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	34.06882	-118.2848	NEW 4-STORIES , 9 UNITS APARTMENT BUILDING WITH NO TYPICAL UNIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32511	13041-10000-11565	18200 W VENTURA BLVD	91356	3	171B125   365	2181008021	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Closed	03/17/2015 12:00:00 AM	ADDRESS	34.16589	-118.52928	New one story 3257 sq ft medical office bldg.  New 400A servie, 120/240, 1phase3wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32512	15041-10000-42534	7666 W LE BERTHON ST	91042	7	207B197    54	2552025027	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.26787	-118.29952	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(12) MODULES(1) ABB PVI3000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32513	18041-20000-09894	340 N OXFORD AVE	90004	13	138B193   242	5521028022	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			03/19/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.07736	-118.30783	Plan check for a fire alarm system for a 4-story apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (60) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32514	16041-20000-10343	10132 N WISH AVE	91325	12	204B133   367	2694003007	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.25508	-118.50771	Plan check for a PV1 roof-mounted PV system. System size is 11.5 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32515	18041-20000-30375	18965 W CARMEL CREST DR	91356	3	162B121   163	2177048015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.14133	-118.54359	Plan check for a PV1 roof-mounted PV system. System size is 13.34 kWdc/11.4 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (46) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32516	19041-10001-53408	616 S STANFORD AVE	90021	14	126A213   213	5147029041	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Approved	07/09/2020 12:00:00 AM	ADDRESS	34.04026	-118.24307	EXPEDITE PER APPLICANT REQUEST. PV2. NEW 139KVA ROOFTOP COMMERCIAL SOLAR SYSTEM WHICH CONSIST OF 557 MODULES (SW FREEVOLT 300W) AND 7 CENTRAL INVERTERS ( 5xFRONIUS 20.0, 1xFRONIUS 24.0, 1xFRONIUS 15.0).SCOPE INCLUDES NEW 150 KVA TRANSFORMER. tHE SYSTEM IS CONNECTED TO AN EXISTING 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32517	13041-10001-18856	5450 W PICO BLVD SUITE 105	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.04862	-118.35714	Field changes to approved set - delta 2 only.  Title 24 plan check only per inspector request.  (((First-time tenant for a small restaurant/cafe tenant space in a 2-story shopping center.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32518	17041-10001-03918	10250 W SANTA MONICA BLVD # 1865	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set under Delta-5&6: add (1) panel at 480V	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32519	18041-10000-25380	6150 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	NEW FIRE ALARM SYSTEM TO A CORE AND SHELL RETAIL BULDING, (7) FA DEVICES AND (1) FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32520	18041-10000-12203	16954 W STRAWBERRY DR	91436	5	162B133    18	2291012015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.14444	-118.50104	INSTALL 14 ADDITIONAL PV MODULES TO AN EXISTING PV SYSTEM PLUS 29.4 KWH BATTERY STORAGE SYSTEM, PLUS 2 NEW SUB PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32521	18041-10000-36954	514 N SWEETZER AVE LOT 7	90048	5	141B173  1035	5528004064	RD1.5-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			09/27/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.08059	-118.37016	NEW 1,200 AMP SERVICE FOR 8 INDIVIDUAL HOMES. PLAN CHECK & PERMIT FOR SERVICE ONLY. THE PERMIT FOR EACH HOME WAS COVERED UNDER BUILDING COMBO PERMIT. BLDG PERMIT 16010-20000-01299	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32522	15041-20000-12895	3640 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.01993	-118.37802	Plan check for power and energy. Project scope is change of use from warehouse to office space. Building is 1-story and existing. Project is core and shell (no tenants are moving in). Work includes a service upgrade to 1200 amps, installation of (4) new panels and associated loads, and lighting. Total lighting area = 24,745 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32523	17041-10000-07531	523 W 6TH ST 8TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24, PC FOR ENERGY ONLY. TI TO 8TH FLOOR RESTROOMS.  SCOPE OF WORK INCLUDES ADDING NEW LIGHTS TO MEN'S AND WOMENS RESTROOMS OF A COMMERCIAL BUILDING ON THE 8TH FLOOR. TOTAL AFFECTED AREA IS 404 SQ. FT. B#16016-10000-23832	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32524	19041-10000-10898	8484 N RINCON AVE	91352	6	192B165   315	2633035022	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.22367	-118.39311	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 22 MODULES (QCELL 285) , 22 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 6.2KWdc and 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32525	14041-10000-18094	4815 E CONVERSE ST	90032	14	142-5A233 418	5213037030	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM			Not Ready to Issue	07/03/2014 12:00:00 AM	ADDRESS	34.08287	-118.18015	Install roof mounted solar system on existing residential building.  Total system size = 5 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32526	07041-10004-24502	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Apartment			09/07/2011 12:00:00 AM			PC Approved	09/09/2011 12:00:00 AM	ADDRESS	34.05562	-118.27458	Change  relocate the RDB2U to room G3-103, change all residential feeders, and remove a circuit from each residential panel.  So load calculations are revised.  See Delta 5 modifications.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32527	19041-20002-42473	16833 W NORDHOFF ST	91343	12	198B133   613	2687005006	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM			PC Approved	01/23/2020 12:00:00 AM	ADDRESS	34.2359	-118.49929	12-10-2019 Changes to an approved set of plan, changes include revised interconnetion point to the Main Service Panel.  Plan check only. All changes has been clouded. $0 FEE PER STATE SENATE BILL SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32528	12041-20000-21612	601 S FIGUEROA ST #375	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM			PC Approved	09/12/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for energy and emergency lighting. Suite 375. 2090sqft. Commercial high-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32529	16041-10000-00198	12401 N NEDRA DR	91344	12	219B137   105	2609022017	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Closed	04/30/2016 12:00:00 AM	ADDRESS	34.29543	-118.49855	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.57KWdc/7.2KWac(33)MODULES-SLEVO #TRIEX U290 BLACK(2)INVERTERS-ABB #-3.6-OUTD-S-US-Z-A(1) 125A load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32530	18041-10000-20698	20170 S WESTERN AVE	90501	15	057B193    33	7351021038	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	33.84807	-118.30903	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32531	18041-30000-35111	1135 N MANSFIELD AVE	90038	4	144B181   376	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.0918	-118.34057	Plan check for a fire alarm system for a 4-story commercial building. Fire alarm consists of (1) FACP and (83) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32532	13041-10001-33052	17046 W COTTER PL	91436	5	162B133    91	2292010029	A2-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/09/2013 12:00:00 AM	ADDRESS	34.14293	-118.50458	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32533	18041-20000-02689	9451 N CORBIN AVE	91324	12	198B117    68	2761040016	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Issued	01/24/2018 12:00:00 AM	ADDRESS	34.24147	-118.56249	PLAN CHECK FOR TITLE 24 ONLY FOR T. I. TO (E) OFFICE. TOTAL AFFECTED AREA = 7358 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32534	13041-20000-14706	13278 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24. 15 PANELS IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32535	11041-10000-23266	175 S FAIRFAX AVE #B	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM	03/15/2012 12:00:00 AM		Permit Finaled	05/10/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	TENANT IMPROVEMENT OF AN EXISTING SHELL SPACE TO A RESTAURANT WITH OUTDOOR DINING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32536	13041-10000-32644	940 S PACIFIC AVE	90731	15	015B197  1022	7455008015	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	33.73536	-118.28777	T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 2585 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32537	18041-30000-04691	3400 W SUNSET BLVD	90026	13	144A203   344	5427026021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Apartment			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	01/20/2021 12:00:00 AM	ADDRESS	34.08744	-118.27608	Plan check for new fire alarm system for 35 units 5 story. Total Fire Alarm devices: 149 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32538	14041-10000-34305	1615 E 15TH ST	90021	14	120A213     6	5130019032	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.02453	-118.24242	Energy plan check only. Remove HID light fuxtures and replace with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32539	19041-10000-36573	1540 S ST ANDREWS PL	90019	10	126B193   256	5073009011	[Q]R3-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	Apartment			12/11/2019 12:00:00 AM	06/15/2020 12:00:00 AM		Permit Finaled	08/29/2023 12:00:00 AM	ADDRESS	34.04409	-118.31142	FULL PC FOR A NEW 1600A MAIN SWITCHBOARD (120/208 3P, 4W), WHICH FEEDS (1) ELEVATOR, (2) HOUSE PANELS, AND (1) EV PANEL. IT IS CONNECTED TO A  1200A DISTRIBUTION BOARD THAT FEEDS THE 38 DWELLING UNIT PANELS. TOTAL AFFECTED AREA IS 30,720 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32540	19041-20000-00595	17400 W TIARA ST	91316	5	177B129   634	2254030020	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.17886	-118.51186	install (1) tesla battery unit 5Kwh to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32541	17041-10001-29696	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM			PC Info Complete	04/11/2019 12:00:00 AM	ADDRESS	34.18684	-118.3977	Change to approved set by updating lighting fixture schedule, lighting floor plan, and new ckts added. All changes under delta-6 only.(((PLAN CHECK FOR POWER AND ENERGY FOR (T.I. TO EXISTING (37,000 SF) RETAIL SPACE, INTERIOR ONLY). PLAN CHECK INCLUDES RELOCATION OF EXISTING 800A DISTRUBUTION EQUIPMEMT & NEW CONNECTED LOAD ~400A. TOTAL AFFECTED AREA 43,185 SQ. FT.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32542	18041-20002-43438	6536 N GAVIOTA AVE	91406	6	180B141   506	2233017029	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.1897	-118.48128	SUPPLEMENTAL CHANGES TO APPROVED SET PV1 DELTA 1 ONLY. CHANGES INCLUDE CHANGES IN AIC RATING AND CONDUIT SIZE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32543	17041-20001-22170	3231 N STEVEN DR	91436	5	159B141   212	2293014019	RE15-1-H	South Valley	Encino - Tarzana	Encino	Yes	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			Reviewed by Supervisor	07/12/2017 12:00:00 AM	ADDRESS	34.13339	-118.48222	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32544	18041-10000-01643	931 S GAFFEY ST	90731	15	015B197   955	7454009908	PF-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	33.73549	-118.29249	FIRE ALARM SYSTEM, (1) FA PANEL, (100) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32545	14041-10000-00015	1029 S TOWNE AVE	90021	14	124-5A211 310	5132010039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.03357	-118.25029	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 481 SQ FT. REPLACING TOTAL OF 2 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32546	12041-10000-20696	600 N HANLEY WAY	90049	11	135B137    45	4494019028	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.06986	-118.48705	Plan check for new 15.696KW roof mounted photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32547	18041-20000-43811	4510 N RADFORD AVE	91607	2	165B169    21	2364006022	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Re-Activate Permit	05/01/2019 12:00:00 AM	ADDRESS	34.15248	-118.39193	pv1install roof mounted pv system sized 15.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32548	18041-10000-23711	900 W WILSHIRE BLVD 18TH FLR	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR AN OFFICE SPACE ON THE 18TH FLOOR OF AN EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 21,000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32549	17041-20003-31073	5738 N OAKDALE AVE	91367	3	174B113   152	2153018019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.17554	-118.56553	04-10-2018 Changes to an permitted set of plan. Changes include increase inverter size to 11.04kW and remove existing inverter. Plan check only. Permit is under 17041-20003-31073	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32550	19041-20001-25262	6225 N CORBIN AVE	91356	3	177B117   332	2153022004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM			PC Approved	07/19/2019 12:00:00 AM	ADDRESS	34.18332	-118.56246	07-19-2019 Changes to an approved set of plan, changes include re-location equipment: Tesla PowerWall, generatio panel, Tesla disconnect, and Energy Gateway. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32551	17041-10000-37671	10914 N SHADOW HILLS AVE	91040	7	207B173   497	2528037005	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	9800.21	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	11/27/2017 12:00:00 AM	ADDRESS	34.26534	-118.36737	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 10.58KWAC 12.42 KWDCSCOPE INCLUDES 46 MODULES WITH MICROINVERTERS. PANEL IS CENTERFED VARIANCE IS ATTACHED TO APPROVED PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32552	16041-20000-40170	24559 W INDIAN HILL LANE	91307	12	186B085    84	2031013046	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.20511	-118.65794	Plan check for a PV1 roof-mounted PV system. System size is 14.2 kWac and consists of (2) inverters, (51) modules, (2) combiner boxes, and (1) load center.$0 permit fee per State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32553	16041-10000-45252	10250 W SANTA MONICA BLVD # 1785	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""SAJE"" Ste. 1785.  Install new panels and its circuits, lights and receptacles. Total effected area: 915 sq.ft.Note: Building permit has been pulled under 16016-10000-31036"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32554	12041-20000-28838	8150 W SUNSET BLVD	90046	5	147B173   327	5554007014	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.09781	-118.36653	T-24 lighting plan check for remodeled office spaces and conference room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32555	13041-20000-09008	11740 W EL CERRO LANE Pv-1	91604	2	159B169   500	2381015009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.13114	-118.3893	PV-1. two 6kW inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32556	18041-10000-10618	5410 W HOLLYWOOD BLVD	90027	13	148-5A193 140	5544021022	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.10154	-118.30765	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32557	16041-20000-28110	11276 N HERRICK AVE	91331	7	210B161   101	2533008018	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.27522	-118.41895	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MAP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32558	19041-20000-01327	7643 N SHADYGLADE AVE	91605	2	186B165    86	2307005020	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.20994	-118.40267	Plan check for a PV1 roof-mounted PV system. System size is 9.57 kWdc/8.79 kWac-CEC and consists of (1) 7.6 kWac rated inverter and (29) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32559	19041-20001-20055	4916 N ENCINO AVE pv1	91316	5	168B129   151	2290004027	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM			PC Approved	06/25/2019 12:00:00 AM	ADDRESS	34.15981	-118.51402	expeditepv1install roof mounted pv system sized 12.285KW AC interconnecte dwith msp.(2) tesla powerwalls ESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32560	17041-10000-13828	528 S PARK VIEW ST	90057	1	133-5A203  30	5154037902	R4-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.06194	-118.2771	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  8400 SQ FT. OUTDOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32561	13041-20001-33386	13029 W VENTURA BLVD	91604	2	165B161   952	2375020018	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM			PC Approved	03/05/2014 12:00:00 AM	ADDRESS	33.9787	-118.31759	change in single line diagram. change in series rating specifications. all changes clouded delta 2. plan check for delta 2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32562	18041-10001-41438	545 S FIGUEROA ST 13TH FLOOR	90071	14	130-5A209 126	5151022001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Info Complete	01/30/2019 12:00:00 AM	ADDRESS	34.0514	-118.2582	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE EXPANDING SCOPE OF WORK AND MODIFICATION OF PROPOSED LIGHTING SYSTEM. Inspector to verify fixture listing. ORIGINAL SCOPE<<<<<TITLE 24 ONLY FOR 544 SQFT ON THE 13TH FLOOR. SCOPE OF WORK INCLUDES LIGHTING FIXTURES AND EMERGENCY LIGHTING WITH 14 NUMBER OF LUMINAIRES IN TOTAL.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32563	19041-10000-24209	1541 W WILSHIRE BLVD SUITE 405	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Issued	07/31/2019 12:00:00 AM	ADDRESS	34.05529	-118.26949	PC (ENERGY ONLY) FOR NON-STRUCTURAL TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. AREA OF SCOPE 706SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32564	14041-20000-31188	8540 S SEPULVEDA BLVD SUITE 111A	90045	11	096B165   472	4107035017	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	33.96016	-118.39599	"T.I. to existing build on the 1st floor in MRI rooms.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy. ""COMPLY WITH DEPARTMENT ORDER effective date12/20/2013. PERMIT TO BE PULLED 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32565	11041-20000-24095	1111 W WILSHIRE BLVD	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Apartment			11/09/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.05259	-118.26348	New fire alarm for a mixed use building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32566	14041-20000-14049	10921 N RESEDA BLVD	91326	12	210B125   622	2717014007	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.2694	-118.53631	PV1.  Install 1.0 kW roof-mounted utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32567	16041-20000-20723	7900 N BALBOA BLVD BLDG D	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	"Plan check for power and energy for Van Nuys Airport Building ""D"" (Delta) aircraft hangar. Service size: 800A. Total area: 32,845 sq ftBuilding Applicant #: 16010-30000-01587"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32568	14041-10011-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	"Revision to approved set noted on delta-31: Revise tenant's suite number on Dist. board ""MS ELA-11"" and ""TSSC"" on the single line diagram. Thsi is plan check only, no permit is needed."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32569	14041-20000-14886	10118 N LURLINE AVE	91311	12	204B109   320	2741026040	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.25408	-118.58406	PV1Install roof mounted solar array on SFD. System size 6kW(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(30) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32570	16041-10000-19113	4203 N VAN HORNE AVE	90032	14	145-5A235  82	5307019040	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.10	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.0942	-118.16981	PV1 solar system installation to a single family home. Installing 23 microinverter modules. Total rated system 4.95	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32571	14041-20000-13710	18341 W LAKE ENCINO DR	91316	5	165B125   397	2184041032	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.14564	-118.53082	PC FOR PV SYSTEM. USING MICROINVERTER ENPHASE M250. USING STANDARD PLAN. TOTAL OF 42 MODULES. SYSTEM SIZE 10.5 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32572	13041-10000-00980	380 WORLD WAY Space T48	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 494 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE  CONCESSION (INK.SACK)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32573	19041-10000-29923	4835 S SEPULVEDA BLVD	90230	11	111B165   200	4215031037	C2-1, R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	34.00052	-118.40294	PLAN CHECK FOR MONITORING SPRINKLER SYSTEM. NEW (1) FA PANEL, (10) FA DEVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32574	19041-20000-06532	20929 W VENTURA BLVD ste 37,38	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ti to an existing commercial space.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for power and energy.SEE COMMENTS........	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32575	18041-10000-13518	7631 N CANOGA AVE	91304	3	186B105    80	2110017059	(Q)MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.20929	-118.59773	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32576	11041-10000-20833	2915 W LOS FELIZ BLVD	90039	13	157-5A207 373	5594006021	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.12679	-118.26282	T-24 lighting plan check for new Chase Bank.  Interior and exterior lighting.  Total load is 348.68 and occupancy load is less than 99	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32577	13041-10000-08852	10030 N WYSTONE AVE	91324	12	204B121   485	2729004018	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	06/17/2013 12:00:00 AM	ADDRESS	34.25295	-118.5469	PV1 SINGLE FAMILY DWELLING. INSTALL ROOF-MOUNTED SOLAR ARRAY; INTERCONNECT MAIN PANEL. TRANSFORMERLESS INVERTERS. SYSTEM SIZE: 14.7 kW. 60 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32578	12041-10006-29913	12760 W MILLENNIUM BLDG A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	CHANGES TO THE UNITS FLOOR PLANS- LUMINAIRES ABOVE ISLAND IN THE KITCHENS HAVE BEEN REMOVED AND REPLACED WITH J-BOXES FOR FUTURE HIGH EFFICACY PENDANT LUMINAIRES (((((((((PLAN CHECK POWER AND ENERGY FOR NEW 4-STORY 100 UNIT APARTMENT COMPLEX. BUILDING 'A'.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32579	19041-20000-52771	1825 S PANDORA AVE	90025	5	132B157   846	4317002025	RD1.5-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	03/03/2021 12:00:00 AM		Permit Finaled	06/29/2023 12:00:00 AM	ADDRESS	34.05594	-118.42439	Plan check for a new 1000A 208Y/120V 3ph-4w service, distribution, power, and lighting for new construction.  Bldg permit under 19010-30000-02934.  14-unit apartment bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32580	12041-10000-03801	189 S THE GROVE DR #H-3	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	T.I.  FOR  'J. CREW MEN'S' INTERIOR TENANT  IMPROVEMENT, NON-STRUCTURAL  LOCATED AT  H-3   TENANT SPACE.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERG3ENCY CKT; PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32581	15041-10000-28883	1818 S THAYER AVE	90025	5	132B157   922	4317003***	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	PIN	34.05534727	-118.42567363	REPLACEMENT OF ONE FOR ONE FIRE ALARM PANEL AND THE ADDITION OF ONE DEVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32582	13041-10001-34447	6015 E FAYETTE ST	90042	14	154-5A229  26	5484004017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.11938	-118.18832	Expedited RSES plan check per applicant request.{{PV1, Install a 2.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32583	12041-20000-29797	12800 W CULVER BLVD 1st level-S.E. QUAD	90066	11	105B157   410	4221031009	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Issued	12/11/2012 12:00:00 AM	ADDRESS	33.98489	-118.42552	Remodeled space of building.  Install lights and plugs. T-24 lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32584	13041-10000-10032	350 S FIGUEROA ST	90071	9	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.05438	-118.2549	Energy plan check and permit for an office highrise bldg TI. Suite 125.  4620 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32585	18041-10000-39200	5200 W WILSHIRE BLVD R1	90036	4	132B181    30	5507024010	[T][Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			10/12/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.06194	-118.3435	Plan check for T24 only, TI on a restroom in R1 retail space. Total area: 71 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32586	11041-10000-16055	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	FIRE ALARM FOR NEW COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32587	16041-10007-34516	6677 W SANTA MONICA BLVD	90038	4	144B185   674	5532022010	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	34.09085	-118.33573	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 3 ONLY. CHANGES INCLUDE TO FEEDERS AND VOLTAGE DROP.<<<Plan check for Power and Energey for (new) 695 units apartment with 24,900 SF of retail, 5 stories. There are (5) services in compliance with article 230.2(C).>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32588	13041-20000-03061	7718 N GRAYSTONE DR PV-1	91304	3	189B089   376	2017027004	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.21155	-118.65415	Plan check for PV. two inverters and over 12kW. Please add SERVICE UPGRADE TO INSPECTION FEE PERIOD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32589	16041-20000-20123	20224 W STRATHERN ST	91306	3	189B113   520	2107019083	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.21547	-118.57377	PV1. ROOFMOUNTED SOLAR SYSTEM. 6.72 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32590	14041-20001-21908	15046 W GAULT ST	91405	6	183B145   209	2220006057	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.19925	-118.46143	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 12kW.(2) SolarEdge SE6000A-US transformerless inverters(52) Solar World SundModule SW280 Poly pv modules(52) SolarEdge P300 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32591	10041-10000-10538	2140 E 7TH PL Loft # A1N	90021	14	124-5A217 350	5166003006	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM			PC Approved	06/03/2010 12:00:00 AM	ADDRESS	34.03337	-118.22846	TI in an existing commercial area in Loft # A1N. Plan Check is for T-24 Energy Calcs and Emergency lights. Permit is for 7 new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32592	19041-10000-09970	12312 N KENNY DR	91344	12	219B137   146	2609020019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	07/27/2019 12:00:00 AM	ADDRESS	34.29365	-118.49873	PV1. NEW ROOFTOP  RESIDENTIAL SOLAR SYSTEM, SIZE AT 11.16 KW DC, 10.10 AC-CEC / 9.920 kW AC.(31) AC MODULES, (1) 100A LOAD CENTER, SYSTEM INTERCONECT TO 225A UPGRADED SERVICE.*NOTE: PERMIT FOR PANEL UPGRADE SHALL BE PULLED UNDER SEPARATE EXPRESS PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32593	16041-20001-08074	13200 N GLADSTONE AVE	91342	7	225B157   709	2510020008	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.31078	-118.42793	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.6 kWac and consists of (3) inverters, (1) load center, (50) modules, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32594	15041-20000-29407	7710 N ETON AVE	91304	3	186B105    19	2109029009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.21008	-118.5955	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (33) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32595	19041-10000-05456	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Install 21 new 76W LED lights between Terminal 2 & Terminal 3. T-24 Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32596	16041-20000-31370	300 N VIA NICOLAS	90272	11	126B117   124	4416002015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Closed	09/21/2018 12:00:00 AM	ADDRESS	34.044	-118.55426	FEE PERMIT $0.00 BY STATE SENATE BILL NO. 1222PV1.  Install 19.32 kW DC roof mounted PV system.  (E) 600 A service.  (56) modules with (2) 7.7kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32597	19041-20000-29446	625 E COLEMAN AVE System-2	90042	14	148-5A231   3	5301011029	[Q]RS-1D	East Los Angeles	Northeast Los Angeles	Hermon	YES	2013.02	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Issued	01/23/2020 12:00:00 AM	ADDRESS	34.10231	-118.18265	pv3install roof mounted pv system sized 21.4KW AC interconnecte with msp.this is system 2 of 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32598	18041-10000-12186	6120 N WOODMAN AVE	91401	2	177B157   573	2330014028	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			Corrections Issued	04/25/2018 12:00:00 AM	ADDRESS	34.18181	-118.43105	PLAN CHECK FOR POWER AND ENERGY FOR NEW TWO STORY (TOTAL 12 UNITS) APARTMENT BUILDING - TYPE VB - OVER ENCLOSED PARKING GARAGE. DISTRIBUTION SIZE = 800A AT 120/240V 3 PHASE. 2 TYPICAL UNITS (TYPE A, AND TYPE B). TOTAL AFFECTED T24 AREA 12500 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32599	13041-20000-11315	22035 W MULHOLLAND WAY	91364	3	165B101    59	2170009033	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.15214	-118.60604	PV1 ONE STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS SYSTEM. 4.6KW SYSTEM WITH 19 MODULES AND 1 INVERTER. [INVERTER: POWERONE PVI-4.2-OUTD-S-US] [SOLAR MODULE: ET SOLAR ET-P660245BB]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32600	13041-10000-32323	4225 N SUNNYSLOPE AVE	91423	4	165B157   645	2360008020	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.14815	-118.42712	PV1, Install 2.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32601	15041-20000-32672	18852 W KILLOCH WAY	91326	12	216B121   169	2820015024	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.2912	-118.54413	PV1. Install roof mounted PV system sized 7.5 kW. Interconnected with main service panel.(30) SolarWorld 280 Modules(30) Enphase Energy M250 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32602	11041-10000-20660	1431-1437 S ELKGROVE CIR BLDG 11	90291	11	111B149   594	4243002071	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.00086	-118.4579	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32603	12041-20000-20430	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.04804	-118.46227	Plan check for energy and emergency lighting. Elevator lobby. 14th floor. 360 sqft. Douglas Emmett Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32604	19041-10001-03998	642 S SYCAMORE AVE	90036	4	135B181   767	5507022022	R1R3-RG	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.06368	-118.34279	changes to approved set - changes include modules - (solar city standard #sc330)original permitInstallation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32605	12041-10000-27961	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/21/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	create electrical rooms and idfrooms and remodel (e) scoreboard control room and levels 1,3,5,6,8, and score board rooms. NOTE THAT FEE WAS DETERMINED BY SUBMITTORSEPARATE APPLICATION FOR NEW SERVICES AND ASSOCIATED EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32606	12041-10003-18224	6655 N NEDDY AVE	91307	12	180B089   185	2034006009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2012 12:00:00 AM			PC Approved	09/27/2012 12:00:00 AM	ADDRESS	34.19236	-118.65508	Revision to the approved plan. Change the grounding to provide bonding. ((((((((((((NEW 10.56 KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32607	13041-20000-08077	15853 W MONTE ST	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.31022	-118.47637	commercial TI c-109	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32608	17041-10001-44322	17909 W PALORA ST	91316	5	168B129   137	2182006018	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			Reviewed by Supervisor	12/19/2017 12:00:00 AM	ADDRESS	34.15972	-118.52223	experdite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32609	15041-20000-39405	1115 S HOPE ST	90015	14	127-5A207 258	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Expired	12/25/2017 12:00:00 AM	ADDRESS	34.04207	-118.26356	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 1024 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32610	15041-20000-11906	5695 S GOLDENEYE CT UNIT 1	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.97898	-118.41086	Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL APPLY TO UNIT # 2 AND #3 OF ADDRESS 5695 GOLDENEYE CORT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32611	16041-10000-38409	2029 S CENTURY PARK EAST 39th FL	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing high-rise building T.I. 39th Floor Total area: 12,180 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32612	19041-10001-45458	7400 N COLDWATER CANYON AVE PV2	91605	2	186B161   521	2324001011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM			PC Approved	12/24/2019 12:00:00 AM	ADDRESS	34.20498	-118.41362	NEW UTILITY INTERACTIVE ROOF MOUNTED SOLAR SYSTEM WITH 22 PV MODULES AND 1 INVERTER ON A COMMERCIAL BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32613	15041-20000-28045	3138 W PICO BLVD	90019	10	129B193  1332	5073008001	C2-1VL	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Info Complete	08/26/2015 12:00:00 AM	ADDRESS	34.04701	-118.31048	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of (1) 800-amp distribution board. No loads under this scope of work. Tenant improvement will be under separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32614	11041-20000-07112	3551 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM			PC Approved	04/11/2011 12:00:00 AM	ADDRESS	34.02066	-118.28531	T-24 TO EXISTING OFFICE BUILDING AT USC WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32615	19041-10000-09175	13334 N RALSTON AVE	91342	7	225B141   146	2501002057	[Q]MR1-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.31423	-118.4745	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32616	16041-10000-44039	1096 N WESTERN AVE 1D , 1E	90029	13	144B193   795	5536023022	C2-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.09041	-118.30895	PC FOR NEW BAKERY. PC FOR T24 ENERGY ONLY. REVISED LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32617	13041-10000-32559	2700 N NORTH BROADWAY	90031	9	120A205    86	5122002015	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.0735	-118.2141	PC for power and energy. Dollar tree tenant improvement.  New connected load is over 400 amp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32618	19041-10000-20559	1717 S WESTERN AVE	90006	10	126B193  1421	5073012034	C2-2D-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	07/10/2020 12:00:00 AM		Permit Finaled	07/06/2021 12:00:00 AM	ADDRESS	34.04214	-118.30925	pc (power and energy) for new store addition. scope of work includes adding new panel and equipment on existing 400 amp and 600 amp main switchboard. scope area 5,876sf. building permit #19041-10000-02878	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32619	16041-10000-35957	10721 W STRADELLA CT	90077	5	144B149    78	4370006031	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.09326	-118.45398	NEW 2-STORY SFD OVER BASEMENT WITH ATTACHED GARAGE, BUILDING 1 OF 3 . 1200 AMP SERVICE WITH 2 ACCESSORY BUILDINGS UNDER DIFFERENT PERMIT NUMBERS PER BUILDING DEPARTMENT.Note: Electrical Permit fees is cover under builidng permit 16010-30000-01645	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32620	17041-10000-08456	6600 N TOPANGA CANYON BLVD #FC-3	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only in existing space food service area, Total area: 325 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32621	19041-10000-50829	2721 N HOLLYVIEW CT	90068	4	153B181   590	5549031***	(T)(Q)RD3-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.11836	-118.34234	NEW PV ROOF MOUNTED SOLAR INSTALLATION WITH SYSTEM SIZE OF 5.7KW DC/ 5.27KW AC, 17 MODULES (HANWHA Q. PEAK 335), 17 POWER OPTIMIZERS (P370), 1 CENTRAL INVERTER (SE5000H-US), AND A MAIN SERVICE PANEL RATED AT 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32622	14041-20000-08028	12121 N ADELPHIA AVE	91340	7	216B161    61	2514006042	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Expired	04/19/2016 12:00:00 AM	ADDRESS	34.29039	-118.41362	PV1.  Install 2.5 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter w/ optimizers: SolarEdge 3000A-US-ZB-U.  10 modules: Canadian Solar CS6P-250PX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32623	14041-10001-04663	4246 N RIVERTON AVE	91602	2	165B177   826	2423022027	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.14715	-118.36614	EXPEDTED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(16) MODULES:  CNADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32624	10041-10000-00728	6451 W WEIDLAKE DR	90068	4	154-5A187  18	5577033025	R1-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2010 12:00:00 AM	02/19/2010 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.11605	-118.32964	Plan check power and energy for single dwelling.  3 Stories over basement.  Building Permit # 05010-30000-03940.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32625	11041-10000-18675	5315 W 102ND ST	90045	11	090B173   164	4129030015	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	09/30/2011 12:00:00 AM	ADDRESS	33.94375	-118.373	INSTALL A NEW SPRINKLER MONITORING SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32626	19041-20001-32886	758 S ALVARADO ST	90057	1	132A203   235	5141019008	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	34.05497	-118.27758	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. CHANGES MADE TO SINGLE LINE. REDUCTION IN MAIN PANEL BOARD SIZE, AND REMOVAL/CHANGE OF PANEL SCHEDULE LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32627	18041-20000-05406	1906 S WESTWOOD BLVD	90025	5	129B153   740	4321011027	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM			PC Approved	02/13/2018 12:00:00 AM	ADDRESS	34.0481	-118.43516	TI for a take-out bakery.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32628	19041-10000-29877	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	02/05/2021 12:00:00 AM	ADDRESS	34.09822	-118.31812	FULL PLAN CHECK FOR POWER AND ENERGY UNDER PHASE 1, SCOPE OF WORK IS A TI (FIRST TIME). PHASE 1 INCLUDES A NEW PANEL AND A 800A DISTRIBUTION PANEL THAT FEEDS VARIOUS SUBPANELS, AND ELECTRICAL EQUIPMENT THAT ARE ALL CONNECTED TO AN ELECTRICAL SYSTEM THAT WAS APPROVED UNDER 16041-10K-43434. ****SERVICE WAS PERMITED UNDER 16041-20000-43434****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32629	14041-20000-05012	20522 W HAMLIN ST	91306	3	180B109   566	2148014010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.18901	-118.5806	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.2KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32630	19041-20000-52169	2000 S AVENUE OF THE STARS Unit 800S	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	10/12/2021 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for Title 24 Energy only, new indoor lighting. Total area: 450 sq ft. B#19016-10000-39483	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32631	19041-20000-46997	2531 N SILVER LAKE TER	90039	4	150A207   323	5439020014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.10391	-118.26161	Install 40.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32632	19041-10000-23251	1530 S BUTLER AVE	90025	11	129B149   526	4261003900	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	04/17/2020 12:00:00 AM	ADDRESS	34.04596	-118.45213	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32633	17041-30001-01664	3272 S MOTOR AVE SUITE A	90034	5	123B161   952	4314024020	M1-1	West Los Angeles	West Los Angeles			2699.07	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.02978	-118.41091	"03/23/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. The tenant space panelboard has been relocated.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAUARANT. "" CITRON CAFE"" 1081 SQFT. SUITE A"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32634	15041-20000-02157	20656 W BERMUDA ST	91311	12	207B109   257	2707024010	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.26524	-118.58392	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.0KW INTERCONNETED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32635	17041-10000-26080	10250 W SANTA MONICA BLVD #1383	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for power and energy on a firts time tenant ""Sunlife Organics"" Ste. 1383. Install (2) 200A panels and (1)75KVA xfmr feeding from DB-ELA44, 1050 sq.ft area."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32636	15041-10000-05063	8368 W 3RD ST	90048	5	138B173   844	5511031023	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Expired	04/17/2017 12:00:00 AM	ADDRESS	34.07279	-118.37236	Plan check for T-24 only. interior T.I. for a retail store. Total area: 809 sq ft. Isnpection Fees per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32637	12041-10000-16493	5443 N KATHERINE AVE	91401	2	174B153  1145	2245024007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.16981	-118.44339	Plan check for new roof mounted 6.24KW Photovoltaic system (SolarEdge transformerless inverter) using DC-DC powerbox.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32638	16041-10000-18386	5111 N MAYWOOD AVE	90041	14	162A223    70	5671010029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	PIN	34.13967044	-118.21202125	PC for T-24 only.  Remove HID fixtures and replace with new LED fixtures.  Total area: 3,328 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32639	19041-20000-19053	3020 N DONA EMILIA DR	91604	2	156B173   151	2380028007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.12612	-118.37675	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM. SYSTEM SIZE IS 21.9KW DC/15.2KW AC. SCOPE OF WORK INCLUDES (60) LG ELECTRONICS PV MODULES WITH SOLAR EDGE P320 OPTIMIZERS, A 100A LOAD CENTER, AND (2) SE7600H-US INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32640	12041-10000-03089	25822 S NORMANDIE AVE	90710	15	033B197   107	7411020039	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Expired	04/30/2014 12:00:00 AM	ADDRESS	33.78873	-118.29726	Plan check for 2 temp 800A services, equipment, and panels to supply temporary trailer yard at Kaiser for construction. Site on Methane Zone all the construction is above the M. zone. Branch circuits and equipment in trailers are prefabricated. Variance was submitted for 30 Days demand reading on each 800 Amp service. Mr. Mike Packard will verify the exact conditions in the field and also the results of the demand readings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32641	13041-10000-35697	3501 W JEFFERSON BLVD	90018	10	120B185  1545			South Los Angeles	WEST ADAMS			2193.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.02572	-118.33394	First tenant in commercial space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32642	12041-20000-28088	521 E VENEZIA AVE	90291	11	108B145  1757	4237003011	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			11/21/2012 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	33.9891	-118.45995	Install indoor and outdoor general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32643	13041-10000-35859	11573 W SANTA MONICA BLVD	90025	11	126B149  1303	4261001029	C2-1VL, R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.045	-118.45378	First time tenant of a restaurant (Honey Boba) to a commercial building.  Install subpanel, branch circuits, and lighting.  Plan check for power and energy.Note: Core and Shell plans approved under 09041-10000-23338.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32644	13041-20000-15068	10817 W SHERMAN WAY	91352	2	183B173    89	2410019044	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.20136	-118.36644	Plan check for industrial/office use building. Existing service, new panels and loads. Recalculate fees at final.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32645	18041-10000-04221	1925 S CENTURY PARK EAST 1900	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLAN CHECK FOR T24 ONLY, INTERIOR OFFICE T.I. TO PARTIAL 19TH FLOOR OF AN (E) OFFICE SPACE IN A HIGHRISE BUILDING. TOTAL AREA UNDER THE SCOPE: 2,016 SQ.FT(B#18016-10000-03667)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32646	12041-10000-27573	725 S FIGUEROA ST 2NDFLOOR	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR T24. TI TO EXISTING HIRISE CORRIDOR 494 SF. 2nd FLOOR.OWNER BROOKFIELD PROP - 725 S. FIG~ LA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32647	17041-10000-32550	7232 N BALBOA BLVD	91406	6	186B133  1044	2226031001	C2-1VL, R1-1, R1P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.20249	-118.50092	Remove HID fixtures and replace with new LED fixture  - Title 24 only. Total affected area 76525sq.ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32648	18041-30000-47987	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Info Complete	12/18/2018 12:00:00 AM	ADDRESS	34.20696	-118.3417	Plan check for Title 24 only. Project site is an existing commercial building (dormitory). Project scope is a tenant improvement. Total lighting area = 3,578 sq. ft.Note: Building permit has been issued under 18016-20000-11016	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32649	18041-20000-06908	8533 W FORSYTHE ST	91040	7	207B189   233	2555003030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.26641	-118.31904	pv1install roof mounted pv system sized 8.2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32650	08041-10001-17061	975 N VENDOME ST 1-36	90026	13	142-5A203 305	5426016003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.01	Electrical	Electrical	Apartment			12/13/2010 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	12/09/2011 12:00:00 AM	ADDRESS	34.08417	-118.27465	ADD PV ON THE ROOF OF AN APPARTMENT BLDG. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32651	18041-20000-36874	235 E 12TH ST	90015	14	124-5A209  66	5145021028	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.03652	-118.25747	Plan check for Title 24 Energy only in existing space T.I. coffee shop. Total area: 280 sq ft. B#18016-10000-24719	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32652	15041-10000-15988	5513 W RIDGE OAK DR	90068	4	153B193   144	5580027020	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.11482	-118.31	PV1, INSTALL 7.19 KW DC ROOF-MOUNTED SOLAR ARRAY ON A RESIDENTIAL HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: SUNPOWER SPR 327ne-wht-d(1) INVERTER: ABB PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32653	19041-20000-50356	19035 W MIRANDA ST	91356	3	174B121   142	2156012024	RS-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.17531	-118.54874	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 10.89 KW DC/10.02 KW AC CEC. SCOPE OF WORK CONSISTS OF (33) PV MODULES WITH MICROINVERTERS, AND A PV LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32654	15041-20000-08652	230 W 90TH ST	90003	8	094-5A203  91	6040033023	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	33.95452	-118.27701	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system with 1 branch circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32655	10041-10001-15139	1511 W FRANCISCO ST Bldg B	90501	15	057B193    25	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM			PC Approved	10/14/2011 12:00:00 AM	ADDRESS	33.85075	-118.30473	New building.  New service, panels, and branch circuits.  Plan check for energy and power.  NOTE: refer to 10041-10K-15136 for Bldg A  ((((((((((((((title 24 addition of one light)))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32656	19041-10000-51928	6268 N OAKDALE AVE	91367	3	177B117   183	2153011026	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.18442	-118.56462	[EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH SYSTEM SIZE OF  11.88KW DC/ 11.34KW AC, WITH 36 PANASONIC MODULES (330W), 36 ENPHASE MICROINVERTERS (IQ7X-96-2-US), 1 ENPHASE COMBINER BOX AND EXISTING MAIN SERVICE PANEL RATED FOR 200A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32657	13041-10000-17687	4519 W COCKERHAM DR	90027	4	153B197   173	5588023037	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.11466	-118.29075	Power only for single family dwelling. PV installation is not part of scope. Panel A, B, C, C1, D and ACP are new.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32658	17041-30001-07167	411 S NORMANDIE AVE	90020	10	135B193   636	5502016007	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.06672	-118.30068	Changes to approved set, noted as Delta-3.  Scope includes:(1) revise electric dryer loads on all 224 units , revise unit load calculation, dist. board calculation, and resize Main Circuit Breakers accordingly.(2) add 50HP Fire pump ahead of the main(3) increase service size and the Swithcboard size accordingly(4) Revise lighting floor plan to add mandatory lighting controls.<<PC FOR POWER AND ENERGY. CONSTRUCTION OF A NEW 7 STORY 224 UNIT APARTMENT BUILDING WITH PARKING AT GROUND LEVEL AND 3 SUBTERRANEAN LEVELS. SERVICE 3000A. TOTAL AREA 201245 SQ FT.ACCORDING TO THE BUILDING DEPARTMENT VARIANCE HAS BEEN FILED AS A LOW RISE BUILDING, FIRE ALARM HAS TO BE FILE SEPERATELY.B# 16010-10000-01635.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32659	19041-10000-46950	100 E SUNSET AVE	90291	11	109-5A143 198	4286015900	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.99395	-118.477	PLAN CHECK FOR A NEW FIRE ALARM SYSTEM WITH 1 FIRE ALARM CONTROL PANELS AND 101 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32660	15041-20000-41228	1558 N GORDON ST	90028	13	148-5A191 269	5545009012	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			12/08/2015 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.09976	-118.31949	NEW 47 unit apartement building , 15 typical units (including 1 gym).  2 level subterannian parking garage. PC for Power and Energy.  Fire alarm plan variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32661	15041-10000-43636	7870 N VAN NUYS BLVD	91402	6	189B149   645	2212028013	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.21426	-118.44738	PC FOR FUEL CELL SYSTEM INTERCONNECTED TO EXISTING MAIN SERVICE PANEL. FUEL CELL UTILITY INTERACTIVE. NET METERED SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32662	18041-20000-47387	20748 W SATICOY ST pv1	91306	15	186B109   255	2113011008	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.20817	-118.58566	pv1install roof mounted pv system sized 3.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32663	11041-10000-25953	11853 N LAUGHTON WAY	91326	12	216B125   131	2870023021	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2011 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	02/22/2012 12:00:00 AM	ADDRESS	34.28922	-118.53398	New 7.6kw rooftop photovoltaic system for a single family residence with 40 modules and one inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32664	14041-10000-18065	2460 E 12TH ST #D	90021	14	120A217   143	5168005021	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.02255	-118.22799	Title 24 plan check only.  Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32665	18041-20000-11681	4257 N NOELINE AVE	91436	5	165B137   273	2284019009	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.14852	-118.48753	pv1install roof ounted pv system sized 11.8kw AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32666	17041-20000-20807	8560 N TUJUNGA AVE	91352	6	192B169   252	2632008009	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Closed	04/04/2018 12:00:00 AM	ADDRESS	34.22512	-118.38032	Plan check for power and energy. Redoing electrical for fire damaged commercial warehouse. New 800A 120/240 3ph 4w. New lighting (incl. emergency) - 8,600sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32667	14041-20000-18202	4451 N CALLADA PL	91356	3	168B121   575	2177012019	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.15267	-118.54287	New roof mounted PV system with total system size 15KW.Note: Permit fee is $0.00 due to Senate Bill from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32668	15041-10001-28503	10802 W AMBAZAC WAY	90077	5	138B149    45	4362007005	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.0779	-118.45114	PC for alterations to approved set. Alterations include upgrading generator to 80 KW and installing new kitchen equipment to emergency panel.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32669	16041-30000-40005	6200 N KESTER AVE	91411	6	178-5A149 198	2241016013	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.1828	-118.4573	Plan check for new Fire alarm system in appartment building. Total fire alarm devices: 68 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32670	19041-10000-23238	1351 S TREMAINE AVE	90019	10	129B181   636	5083021002	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Issued	07/03/2019 12:00:00 AM	ADDRESS	34.04988	-118.34044	(ePlan) PV1 Roodtop slar system 6.12 KWdc/5.514KWac P.V. system with ESS: Install  (17) modules with (17) power optimizers, (1) 6.0 kW Inverter,  (1) 13.5 kWh tesla Power wall, (1) 125A load center. System connect to new 225A Main service panel.*Note: 225A New Main Service Panel shal be under separate express permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32671	16041-20000-04964	627 N MARTEL AVE	90036	5	141B181   741	5526019008	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.08262	-118.35123	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. System size: 6.88kW(32) 215W Enphase microinverters(32) 255W pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32672	19041-10000-07033	8763 N LANKERSHIM BLVD	91352	6	195B169   425	2631012049	CM-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	08/06/2021 12:00:00 AM	ADDRESS	34.22901	-118.38796	EENRGY PLAN CHECK FOR STUDIO TI. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 4,000 SQ. FTBulding Permit: 19016-10000-05599	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32673	13041-10000-35964	1361 W 190TH ST STE 120	90248	15	060B193   382	7351001020	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	33.85852	-118.3026	T.I. to existing Autozone store.  New 800A service, panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32674	17041-10002-06248	25835 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			PC Approved	01/05/2018 12:00:00 AM	ADDRESS	33.78945	-118.29472	Change to approved set by changing the equipment grounding conductor size. all changes under delta-4 only.(((PC FOR FUEL CELL SYSTEM. INTERCONNECTING TO 2 DIFFERENT SERVICE MEETERS. THIS IS PROJECT 1/2. SPECIFIC FOR ADDRESS 25835 VERMONT. CONTROL SYSTEM AND LOCATION IS SHARED WITH OTHER PROJECT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32675	16041-10000-31260	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	ADDITION 745 FA DEVICES AND 58 (FATC&BPS)  TO EXISTING FIRE ALARM SYSTEM IN HIGH-RISE BUILDING 'SUNSET BRONSON STUDIOS NETFLIX'.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32676	18041-10000-22651	2020 W OLYMPIC BLVD	90006	1	130-5A203 225	5136012031	QC2-1	Central	Westlake	Pico Union		2095.20	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.05112	-118.27903	Plan check for T24 only, TI on existing McDonald, install (2) new panels, new load < 200A, total area: 3,200 sq.ft(B# 18014-10000-03157)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32677	19041-20000-35723	5938 N CORBIN AVE	91356	3	177B117   703	2153024015	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Closed	10/24/2022 12:00:00 AM	ADDRESS	34.17862	-118.56196	Plan check for PV roof mounted system, PV system size: 11.34KW with 36 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32678	14041-20000-20967	8772 N SNOWDEN AVE	91331	6	195B153   808	2640022008	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Expired	09/06/2016 12:00:00 AM	ADDRESS	34.2295	-118.43401	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32679	19041-10001-33709	12025 N WOOD RANCH ROAD	91344	12	216B129   130	2601068017	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.29008	-118.52373	EXPEDITE FEESPV1 NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 12.95 KWdc/11.4 KWac. SCOPE OF WORK IS 35 MODULES (LG370Q1C-V5) WITH OPTIMZERS (SE P370) LEADING TO TWO CENTRAL INVERTERS (SE3800H-US AND SE7600A-US) WITH A BATTERY BACKUP (LG CHEM RESU 10H).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32680	15041-10000-06816	10715 W MAGNOLIA BLVD	91601	2	171B177   639	2416025027	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.16507	-118.3641	REPLACING HID LUMINAIRES IN A WAREHOUSE WITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32681	16041-20000-32997	22129 W MARTINEZ ST	91364	3	171B101   869	2169022010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.1629	-118.60985	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.6 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32682	12041-20001-12405	337 N FAIRFAX AVE	90048	5	138B177   222	5527036017	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	PIN	34.0772296	-118.3617713	ENERGY PLAN CHECK RETAIL revision	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32683	10041-10000-24677	10518 N JOHANNA AVE	91040	7	207B181   253	2549024018	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2010 12:00:00 AM			PC Approved	01/03/2011 12:00:00 AM	ADDRESS	34.26058	-118.34652	Photovoltaic system on roof.PLAN REVIEW IS FOR PLAN CHK ONLY PERMIT WAS OBTAINED ON 09041-10000-23628	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32684	13041-10001-11962	1126 N HOOVER ST	90029	13	145-5A201 419	5429001011	R2-1XL	Central	Hollywood	Greater Griffith Park		1913.01	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.09172	-118.28441	MINOR CHANGES TO APPROVED SET OF PLANS. SYSTEM SIZE CHANGED FROM 5.39kW DC TO 4.08kW DC. PV PANEL PLACEMENT HAS BEEN MODIFIED. FEES CHARGED PER APPLICANT.Install roof mounted Microinverter P.V. system with 4.752 Kw.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32685	14041-10001-19401	5856 1/2 S FIGUEROA ST	90003	9	108B201  1521	6004036011	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM			PC Approved	08/06/2014 12:00:00 AM	ADDRESS	33.98811	-118.28246	EXPEDITE FEE ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32686	14041-10002-02446	20000 S WESTERN AVE	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM			PC Approved	07/31/2014 12:00:00 AM	ADDRESS	33.85008	-118.30908	[[[[[[7/31/14 CHANGES TO APPROVED SET OF PLANS. DELTA 1 CHANGES ONLY. REMOVAL OF PREVIOUSLY DWP REQUIRED ISOLATION TRANSFORMER.  BONDING OF INVERTER GEC WITH THE SERVICE GEC. ]]]]]]MASTER APP: PV2 PHOTOVOLTAIC SYSTEM. TOTAL SYSTEM SIZE 930KWAC WITH ISOLATION TRANSFORMER. ***ZERO FEES DUE TO 2012 SENATE BILL 1222.***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32687	14041-10000-28892	111 N HOPE ST	90012	14	133-5A211 168	5161003910	PF-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.05807	-118.24862	INSTALLATION OF NEW 3000 AMP LOAD CENTER AND AN 800-HP CHILLER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32688	17041-10000-00292	"5927 W IMPERIAL HWY Area ""C"""	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	33.93319	-118.38745	"Plan check for Title 24 only in existing FedEx Facility outdoor lighing. Area ""C"". Total lighing area: 223,392 sq ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32689	13041-10000-22485	11040 W PICO BLVD	90064	5	126B153  1136	4256008014	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			Reviewed by Supervisor	08/26/2013 12:00:00 AM	ADDRESS	34.03753	-118.43352	PC FOR POWER AND ENERGY. TI TO (E) RETAIL.  99c STORE FULL TENANT IMPROVEMENT. 1000A service. previously a furniture store. not a methane zone. WITH PARKING LOT RE-STRIPING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32690	17041-10000-09069	5440 W CENTURY BLVD	90045	11	090B173   124	4129029011	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	33.94511	-118.37573	PC FOR ENERGY ONLY. REPLACEMENT OF EXISTING LIGHTING WITH MORE ENERGY EFFICIENT TYPE. TOTAL WORK INCLUDES OFFICE TI AND GARAGE LIGHTING REPLACEMENT. NEW LOADS TO EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32691	13041-20000-34228	4520 E HUNTINGTON DR NORTH	90032	14	142-5A229 296	5305035006	RD2-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM			Reviewed by Supervisor	12/19/2013 12:00:00 AM	ADDRESS	34.08413	-118.19022	New 17.28kw rooftop PV system for an existing single family residence with 600 amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32692	17041-20000-35758	6303 N OWENSMOUTH AVE 1st Floor	91367	3	177B105   123	2146029016	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Issued	11/17/2017 12:00:00 AM	ADDRESS	34.18474	-118.60182	Tenant improvement to (E) office space in a highrise commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32693	18041-20001-48297	13160 W MINDANAO WAY Suite 202	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	03/04/2022 12:00:00 AM	ADDRESS	33.98501	-118.43726	7/15/2019changes to an approved set of plans.  addition of 2 transformers and panels, changers to lighting design and revised energy calculations.  ((((Plan check for power and energy. Project site is an tenant suite in an existing commercial building. Project scope is a change of use from office to medical office. Total lighting area = 1,838 sq. ft.Note: Building application has been generated under 18016-30000-40639.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32694	11041-10000-15039	1416 N AMALFI DR	90272	11	132B133   297	4425018002	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2011 12:00:00 AM	10/19/2011 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.05511	-118.50389	NEW SFD ; NOTE THAT BUILDING PERMIT WAS OBTAINED IN 2010	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32695	18041-20000-28658	12586 N COMETA AVE	91340	7	219B157   219	2513022017	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Issued	07/31/2018 12:00:00 AM	ADDRESS	34.29865	-118.42484	Plan check for PV roof mounted system, system size: 3.5kW with 11 pv modules and 11 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32696	16041-10000-44572	19424 W WYANDOTTE ST	91335	3	186B117   889	2116018901	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.20281	-118.55653	PC FOR ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 17,600 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32697	16041-10000-37785	300 S FERRY ST PV	90731	15	018B205    66	7440023***	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	03/30/2021 12:00:00 AM	ADDRESS	33.74748	-118.26198	PERMIT FEE IS $0.00 DUE TO SENATE BILL 1222PC FOR PV FEED IN TARRIF (FIT), Roof mounted PV system. SYSTEM SIZE 645KW.DC  581KW.AC SCOPE INCLUDES TOTAL OF 1199 MOUDULES AND 7 INVERTERS (83KVA).WITH NEW DEDICATED SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32698	17041-10000-26084	721 E BROOKS AVE	90291	11	111B145  1266	4239007006	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	33.9972	-118.46561	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE (3.6KVA) WITH BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF 1 INVERTER (ABB PVI 3.6) WITH 15 MODULES (SOLARCITY).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32699	19041-10000-34006	1771 W BLAKE AVE BLDG 8	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/30/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	8 OF 11. BLDG 8POWER PLAN CHECK FOR 1200A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDING AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32700	16041-10000-27438	12740 W ARROYO ST BUILD. E	91342	7	219B161   249	2525027014	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.29585	-118.41002	Plan check for T-24 only.  Remove indoor and outdoor HID fixtures and replace with new LED fixtures. Affected area: 53,444 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32701	14041-20000-01021	8134 W FOOTHILL BLVD	91040	7	204B193   156	2559001010	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.2595	-118.31045	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN NON MEDICAL FACILITIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32702	13041-10000-00954	18606 W VINTAGE ST	91324	12	201B121    75	2729020022	RS-1	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2013 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	34.25072	-118.53863	New 5.39 roof mounted PV1 using micro inv. enphase 215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32703	13041-20000-25437	23234 W ARMINTA ST	91304	12	189B093   543	2020022022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.21256	-118.63329	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5 KW AC USING 24 MODULES. 3 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32704	18041-20000-29001	4827 N FULTON AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.15858	-118.42347	new fire alarm system 94 devices plus FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32705	18041-20000-43362	5644 N BUFFALO AVE	91401	2	174B157   448	2343007028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.17339	-118.43001	pv1install roof mounted pv system sized 12KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32706	19041-10001-25603	8545 N HATILLO AVE	91306	3	192B113    95	2782016011	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.22574	-118.56523	EXPEDITE FEES FOR PV-1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32707	19041-10000-12636	15206 W ROXFORD ST	91342	7	228B145   470	2501020036	C1-1VL-K-CPIO	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.31803	-118.46363	Plan check for a sprinkler monitoring system with (1) fire alarm panel, (1) communication panel, and (10) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32708	10041-20000-11492	7040 N SEPULVEDA BLVD	91405	6	183B145  1121	2220022010	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	01/07/2013 12:00:00 AM	ADDRESS	34.19889	-118.46596	Plan check T-24 Energy (general/emergency) lighting for Bank TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32709	16041-10000-09976	11026 N SWEETWATER CT	91311	12	210B117    97	2708009015	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	EXEMPT	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.27042	-118.5633	PV1 ROOF MOUNTED SOLAR SYSTEM 3.8KW AC   (16) SPR-X20-250-BLK.    (1) SB3800TL-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32710	18041-30000-15574	350 S GRAND AVE Suite 3000	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only. Project site is the 30th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 11,940 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32711	12041-10000-22318	945 S HIGHLAND AVE	90036	4	132B181   651	5084006029	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.05749	-118.34002	SFD ROOF-MOUNTED 4.2 KW PHOTOVOLTAIC SYSTEM USING MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32712	10041-10000-08464	13020 W PACIFIC PROMENADE 1-72	90094	11	102B157   226	4211029***	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM			PC Approved	05/06/2010 12:00:00 AM	ADDRESS	33.97287	-118.42296	TI. CHANGE FROM BEAUTY SUPPLY STORE TO YOGA STUDIO ON THE FIRST FLOOR. PLAN CHECK FOR T24. (THERE IS A PAKING STRUCTURE UNDER THE BUILDING AND THE METHANE MITIGATION SYSTEM DOES NOT APPLY TO THIS LEVEL. PLAN CHECK ONLY. PERMITE IS ALREDY ISSUED)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32713	10041-10000-15840	5905 W WILSHIRE BLVD	90036	4	135B177   424	5508016901	PF-1D	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	34.06282	-118.35793	revisions to lighting system for ticket kiosk/storage area  at the LA County  Museum of Art. Original permit obtaine don 10041-10000-08990PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32714	16041-20000-03776	1999 S AVENUE OF THE STARS 6TH	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 6TH LEVEL OFFICES. HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32715	16041-10000-30443	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	33.97615	-118.42138	NEW FIRE ALARM SYSTEM FOR 2-STORY COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32716	15041-10000-11682	3617 S 4TH AVE	90018	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.02229	-118.32141	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32717	15041-10000-35195	8635 W 3RD ST STE 800-885	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.07373	-118.38073	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK IN THE 8TH FLOOR ONLY.BUILDING APPL# 15016-10000-03698FIRE ALARM VARIANCE ON FILE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32718	18041-10001-19752	20701 W SESNON BLVD	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM			PC Approved	08/28/2018 12:00:00 AM	ADDRESS	34.29478	-118.58219	08/28/2018CHANGES TO AN APPROVED SET OF PLANS, CHANGES NOTED UNDER CLOUDED AREAS. SCOPE OF WORK INCLUDES THE CHANGE OF FIXTURES NOTED ON DELTA 1. PLAN CHECK ONLY, PERMIT FEES UNDER MASTER APP. ________________INSTALL LIGHTS IN PRIVATE ROADS FOR TRACK HOMES. EFFECTED AREA 120,000 SQR FT.PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32719	19041-20000-00485	10205 N VANALDEN AVE	91324	12	204B121   215	2729027047	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.25585	-118.54941	Plan check for PV roof mounted system, system size: 12.54kW DC, 12.0KW AC with 38 PV Modules and 2 inverters(9.0kW and 3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32720	14041-10000-00025	317 S BROADWAY F9-F10	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.05069	-118.24861	T24 PART 6 ENERGY FOR (E) 472 SQ FT DELI/RESTAURANT IN NON-HIGH-RISE BUILDING. SCOPE OF WORK < 400A. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER. NOTE: PERMIT FEE ALREADY CALCULATED; PLEASE SEE INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32721	10041-20000-13464	19401 W BUSINESS CENTER DR	91324	12	195B117    41	2783025072	MR2-1	North Valley	Chatsworth - Porter Ranch			1133.01, 1134.01	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.23152	-118.55592	ENERGY PLAN CHECK OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32722	13041-10000-05577	1306 N L. RON HUBBARD WAY	90027	13	147B197  1062	5543016019	C2-1	Central	Hollywood	East Hollywood		1912.01, 1912.03	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.09574	-118.29377	RENOVATION OF CHURCH. PC FOR POWER AND ENERGY. MOSTLY ENERGY CHANGES. MINOR ELECTRICAL CHANGES. TOTAL AREA 43239 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32723	15041-10000-28553	11955 W BLUFF CREEK DR	90045	11	105B165   919	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM			PC Approved	08/31/2015 12:00:00 AM	ADDRESS	33.9836	-118.40144	PC for SPRINKLER MONITORING SYSTEM. This application is for pc only. Permit fees paid under app # 15041-10000-22760	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32724	13041-10000-29609	1 WORLD WAY terminal 4-T33	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	33.94469	-118.39817	"TITLE,24 PART 6 LIGHTING TO INSTALL ILLUMINATED BLADE SIGN 4'10""W' X 5/8""H FOR LAX TERMINAL 4, FOODCOURT. SIGN READS ""panda express"" total sign area = 8.33 sq ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32725	17041-20000-41326	3740 S MCCLINTOCK AVE 3rd & 5th	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.01972	-118.29033	Plan check for Title 24 only. Project site is multiple rooms on the 3rd and 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 957 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32726	16041-10000-44035	10250 W SANTA MONICA BLVD # 1997	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Uno de 50"" Ste. 1997.  Install new Xrfmr, and  panels, total area 1180 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32727	18041-10000-37672	1533 N SCHRADER BLVD Membrane-Bldg	90028	13	147A187    32	5547018901	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.09901	-118.33257	New emergency temporary shelter for the homeless consisting of two state certified modular buildings-Admin Bldg; Hygiene Bldg  and newly constructed Membrane Bldg-This application is for the Membrane building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32728	12041-20000-08828	9225 N RESEDA BLVD	91324	12	198B125   229	2763009035	C1-1L, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	05/31/2012 12:00:00 AM	ADDRESS	34.23795	-118.53628	TI for retail space. Plan check for energy and emergency lighting. 1191 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32729	13041-10000-00910	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.11883	-118.2495	PLAN CHECK FOR POWER AND ENERGY. NEW 2-STORY NORTHEAST LAPD POLICE STATION AND NEW 2000A SERVICE SUPPLYING FUTURE PAKING STRUCTURE, FUTURE MAINT. BLDG, AND FUTURE CAR WASH BLDG. FACILITY NOT A CRITICAL OPERATIONS POWER SYSTEM (COPS) PER LAPD LETTER. MODIFICATION TO SEPARATE FIRE ALAM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32730	14041-20000-27233	1020 S FEDORA ST 1st Floor	90006	1	129B197   286	5078015023	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Expired	11/01/2016 12:00:00 AM	ADDRESS	34.0522	-118.29776	TI to (E) commercial hotel first floor lobby and 2nd floor gym area.  Plan check for Title 24 Part 6 under 2008 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32731	19041-20000-16102	4618 N NOBLE AVE	91403	4	168B145   816	2264013008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.15461	-118.46163	Plan check for a PV1 roof-mounted PV system. System size is 7.725 kWdc/7.6 kWac and consists of (1) inverter and (27) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32732	15041-20000-41498	11336 N HAYVENHURST AVE	91344	12	213B137   880	2681014001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.27664	-118.49324	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.45KW.(30)MODULES-KYOCERA 265 POLY BLACK FRAME (30) MICROINVERTERS-ENPHASE M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32733	17041-10000-32900	10250 W SANTA MONICA BLVD # 1260	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Plan check for T24 only, TI on existing tenant space ""Yogurtland"" Ste. 1260,  reusing existing panelboards."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32734	16041-10000-27194	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.97954	-118.41361	PC FOR POWER AND ENERGY. T.I FOR MEDICAL OFFICE. ADDITION OF 2 NEW PANELS(225A) TO EXISTING SINGLE LINE DIAGRAM, AND LOADS TO 2 EXISTING PANELS, SCOPE OF LIGHTING AREA 18857 SQ FT. PC IN ACCORDANCE TO ART 517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32735	19041-20001-50568	6014 N FAIR AVE	91606	2	177B173  1112	2337005024	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.17989	-118.37457	12/23/19$0 FEE PER AB1414. CHANGES TO APPROVED SET DELTA 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32736	11041-10002-13633	5115 W WILSHIRE BLVD Suite B&C	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/10/2011 12:00:00 AM	11/10/2011 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.06233	-118.34134	T.I.  Exisitng restaraunt in suite # B & C on the first floor of a six story, Low Rise building. (Changes to Approved Plans).  Remodeling of light fixtures.  Plan check is for T-24 Energy only. Complete Plan Check may be required, subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32737	11041-10001-24386	956 E LAKE ST BLDG 4-3	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/23/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.0012	-118.46086	Lincoln Place Apartment Building Project.  New 2-story apt. building with 4 units.((((((((((((((((((((((   7-23-14  Addition of two E.V chargers.   M.Z.)))))))))))))))))))))))))	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32738	17041-20000-32564	9721 N WORNOM AVE	91040	7	201B181   213	2544001027	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM			Reviewed by Supervisor	09/19/2017 12:00:00 AM	ADDRESS	34.24632	-118.35212	PV1.,  Install 6.5 kW roof mounted grid tied PV system.  (20) modules with (1) 6 kW rated string inverter with power optimizers.  13.5 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32739	18041-10000-35565	1255 S ELDEN AVE	90006	1	129B197  1063	5076018023	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			09/18/2018 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	01/06/2021 12:00:00 AM	ADDRESS	34.04755	-118.28789	Full plan check for a 7-story, 90-unit apartment building (AFFORDABLE HOUSING)  with a 2500-Amp 120/208v  3-phase service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32740	18041-10000-06373	1888 S CENTURY PARK EAST	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.06104	-118.41402	REMOVE ROOF EMERGENCY GENERATOR AND RECONNECT EMERGENCY LOADS THROUGH TRANSFER SWITCH AND EXISTING EMERGENCY GENERATOR LOCATED AT BASEMENT LEVEL.NOTE: MIKE PACKARD IS AWARE OF THIS ALTERATIONS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32741	15041-10000-14524	10285 S POST WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM			PC Info Complete	05/12/2015 12:00:00 AM	ADDRESS	33.94231	-118.39697	TI TO AN EXISTING COMMERCIAL BUILDING. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32742	17041-10001-15753	10576 W TROON AVE	90064	5	126B161   681	4318019007	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.03763	-118.41615	PC FOR CHANGES TO APPROVED SET OF PLANS. THIS APPLICATION IS FOR PV SYSTEM ADDITION TO AN EXISTING PV SYSTEM. APPLICATION WILL COVER RECHECKING PLANS AND PERMIT FOR LOAD CENTER PV ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32743	14041-10000-01572	1724 W 254TH ST	90717	15	036B193   928	7410013059	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	33.79339	-118.30869	PV1, Install 5.25 kW DC roof-mounted solar array for a two story house, interconnect with existing service panel. (1) Transformerless inverter(s):n Solaredge SE5000A-US. (21) Modules: TRINA SOLAR TSM-250PA05.18.(21) Optimizer:SOLAREDGE  OP250-LV-AH4SM-2NA-Z.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32744	13041-10000-27126	8900 N MOORCROFT AVE	91304	12	195B101    92	2004023008	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.23252	-118.60978	PV1. ROOFMOUNTED SOLAR ARRAY. STANDARD PLAN.  SYSTEM SIZE: 10 kW.(40) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32745	15041-10000-17063	12508 W OSPREY LANE #1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			PC Approved	06/03/2015 12:00:00 AM	ADDRESS	33.97856	-118.41138	PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 1 SIZED 1.38KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19571.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32746	13041-10000-36089	128 N ELLITA PL	90042	1	150A227    23	5468017008	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/24/2014 12:00:00 AM	ADDRESS	34.10733	-118.19953	PV1, Install 1.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Power-One AuroraPVI-3.0-outd-s-us. (6) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32747	16041-10000-14732	8840 S READING AVE	90045	11	096B169   967	4125017009	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	33.95666	-118.38145	PC FOR POWER AND ENERGY TO AN 8- UNIT 2 STORY APARTMENT. 600 AMP O.H.P.S  SERVICE AND 2 TYPICAL UNITS. TOTAL SQ. FT. 4113.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32748	19041-20001-38669	5450 W WASHINGTON BLVD	90016	10	126B177  1515	5063013016	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Info Complete	12/19/2019 12:00:00 AM	ADDRESS	34.03799	-118.3621	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGES MADE TO ALL PAGES, ADDITION OF (3) 6 KW EQUIPMENTS . CHANGE TO LIGHTING FIXTURES USED, FIXTURE SCHEDULE, LIGHT QUANTITY, POWER PAGE LAYOUT, T24 VALUES, PANEL SCHEDULE VALUES, AND PHOTOMETRICS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32749	17041-10001-32353	8500 W BEVERLY BLVD STE 784	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGES TO AN APPROVES SET OF PLANS, CHANGES INCLUDE REVISION OF LOAD AND LIGHTING UNDER CLOUDED DELTA 3. _________________________PC for power and energy for  retail TI. Total load over 400A.  Installing new panels, circuits and equipment. Building# 17016-10000-24524. Total area of 8089sft. Low voltage is not subject to this plan check	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32750	13041-10000-00251	3364 W GARDEN AVE	90039	13	153B209   623	5437005002	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2013 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.11491	-118.25851	pv system for single story, single family dwelling. utilizes 14 microinverters. Inverter - enphase m215-60-2ll-s22. solar panel - rec 245 pe.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32751	18041-20000-37872	18370 W BURBANK BLVD ste 707	91356	3	174B125   449	2160011029	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Issued	10/09/2018 12:00:00 AM	ADDRESS	34.17159	-118.53338	ti to an existing commercial building (medical office).  adding new panel and plugs only.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32752	16041-30000-23815	3200 W ADAMS BLVD	90018	10	123B189   714	5052015032	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.03243	-118.31875	Plan check for a fire alarm system for an existing commercial building. Fire alarm system consists of (1) FACP, (1) communication panel, and (30) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32753	18041-10000-37006	14400 W ROSCOE BLVD	91402	6	192B149   397	2212004011	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.22142	-118.44716	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32754	13041-10000-36033	414 N AVENUE 61	90042	1	154-5A229 369	5484018020	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Expired	05/05/2016 12:00:00 AM	ADDRESS	34.11605	-118.19165	PV1, Install 2.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (9) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32755	19041-30000-18568	1601 N VINE ST Suite 101	90028	13	148-5A187 367	5546009***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.09996	-118.32693	Plan check for Title 24 only. Project site is a suite on the 1st floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,800 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32756	14041-10000-24370	11801 W VENTURA BLVD	91604	2	162B169   272	2368006016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.14212	-118.38916	Tenant improvement in an existing restaurantplan chk is for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32757	10041-20000-23821	13421 W VAUGHN ST	91340	7	213B157   435	2523013902	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			Corrections Issued	02/17/2011 12:00:00 AM	ADDRESS	34.27983	-118.4252	Plan check for new installation 39.16KW photovoltaic system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32758	14041-20000-06540	6902 N MAYNARD AVE	91307	12	183B097   682	2024027038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.19564	-118.62203	PV1 ROOFTOP TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. 7.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32759	16041-20000-22303	3401 E 15TH ST	90023	14	117A225   113	5192013033	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			Corrections Issued	06/24/2016 12:00:00 AM	ADDRESS	34.01585	-118.20663	Plan check Title 24 only for addtion space. Total area: 1,104 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32760	16041-20000-31423	11107 W KLING ST	91602	4	168B173   694	2353031017	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	PIN	34.15585064	-118.37261494	Plan check for a PV1 roof-mounted PV system. System size 5.9 kWac and consists of (17) AC PV modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32761	12041-10000-23279	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM			Reviewed by Supervisor	11/09/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	TI in an existing apple store, suite 54 in the century city mall. New panels, and ckts. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32762	13041-10000-35930	721 E 12TH ST STE #4	90021	14	124-5A211 307	5132012106	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.03348	-118.25258	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 384 SQ FT. TOTAL OF (2) UNITS WILL BE REPLACED. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32763	13041-10001-20786	1530 N HILLHURST AVE 1st & 2nd	90027	4	147B197   561	5542006022	[Q]C2-2D	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.09931	-118.28724	[[[[[[[[[CHANGES TO APPROVED SET OF PLANS, REPLACING LUMINAIRES IN 1480 SQFT AREA]]]]]]]]]TI for clinic (healthcare faciilty) on 1st and 2nd floors. Lobbies, check-in, nursing, exam rooms, and relocate rest rooms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32764	16041-30000-15829	6904 N VANTAGE AVE 122	91605	2	183B165   722	2321010***	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.19578	-118.39751	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (21) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32765	18041-10000-41072	1410 S SPENCE ST	90023	14	118-5A225 442	5191022026	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Issued	10/26/2018 12:00:00 AM	ADDRESS	34.01691	-118.20264	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32766	19041-20000-47716	13263 N WHEELER AVE UNIT 6	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32767	12041-10000-14357	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for energy and emergency lighting. TI for suite 2500 in XEROX building. 3775 sqft. Commercial high-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32768	16041-10000-11165	3560 S MAPLEWOOD AVE	90066	11	111B149   189	4245004015	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.00336	-118.44736	ADD TO (E) SOLAR SYSTEM: 2.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(9) MODULES: YINGLI YL250P-29B(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32769	19041-10000-39945	5380 E ALHAMBRA AVE	90032	14	139-5A235 222	5220031007	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	06/18/2021 12:00:00 AM		Permit Finaled	07/20/2022 12:00:00 AM	ADDRESS	34.07668	-118.16837	FULL PLAN CHECK FOR A CHANGE OF USE FROM A WAREHOUSE SPACE TO A OFFICE AND RESEARCH AND DEVLOPMENT SPACE (NON MEDICAL). SCOPE OF WORK INCLUDES A NEW 800A (120/240 3P 4W) SERVICE FEEDING VARIOUS SUBPANELS, AND ONE TRANSFORMER. TOTAL AFFECTED AREA IS 9840 SFQT. B#: 19016-10000-30619	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32770	16041-20000-04581	22005 W TULSA ST	91311	12	210B101    73	2723005052	(T)(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.26641	-118.60672	Plan check for a PV1 roof-mounted PV system. System size is 6.3 kWac and consists of (25) modules, (25) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32771	17041-10000-02827	23356 W VANOWEN ST	91307	12	180B093    66	2036021010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.19325	-118.63647	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.9KVA(10)MODULES-SOLARWORLD SW 290 MONO(1)INVERTER-SOLAREDGE SE3800A-US(1)OPTIMIZERS-SOLAREDGE P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32772	13041-20000-27892	1500 E ANAHEIM ST	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	33.78074	-118.24357	"30kw rooftoop PV system for a new commercial building.  System is Ungrounded. "" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32773	14041-10001-29424	110 W 11TH ST	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			PC Approved	01/08/2016 12:00:00 AM	ADDRESS	34.0392	-118.25858	Full plan check for a change of use due to a LOST PLAN. Plan is for plan check only(((CHANGE OF USE FROM LIGHT MANUFACTURING TO OFFICE (2ND FLOOR TO 7TH FLOOR). CORE AND SHELL ONLY FOR FUTURE TENANTS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32774	14041-10000-10021	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.03396	-118.24117	TI , title 24 only reatil store, building permit has been issued and CRA clearnace was obtained,new panels and circuits,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32775	14041-20000-23717	15845 W LASSEN ST	91343	12	201B141   190	2669025005	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.25025	-118.47775	PV1.  Install 4.59 kW roof-mounted, utility-interactive PV system with 18 (N) modules.  Existing 4.8 kW roof-mounted system with 20 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32776	15041-10000-07276	10731 1/2 W ARMINTA ST	91352	2	189B177   392	2409007016	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Expired	04/05/2017 12:00:00 AM	ADDRESS	34.21389	-118.36494	PV1 INSTALL 5.559 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(17)MODULES, (1)INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32777	15041-10006-24962	8533 N WOODLEY AVE	91343	12	192B137   107	2689025027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM			PC Approved	11/08/2016 12:00:00 AM	ADDRESS	34.22563	-118.48545	11/08/16Changes to approved set of plans. All changes are made under delta 6. Revising conduit sizes on the single line diagram.Note: Permit is paid under PCIS#15041-10000-24962	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32778	13041-10007-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta 14 revisions:revsed loads on LBHS by adding a sub panel L4BM1 and new circuits;add loads to panel  UPS . BOTH LBHS and  PANEL UPS AREE SUPPLIED FROM  HBHS.     Replacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32779	16041-10000-26764	6643 N BOBBYBOYAR AVE	91307	12	180B093   321	2036003007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.191	-118.63271	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(14)MODULES-SOLARWORLD SW290 MONO(14)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32780	19041-10000-45771	8927 W 25TH ST	90034	10	126B169  1215	4302015025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.03873	-118.38628	[EPLAN] NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 6.27KW DC/ 5.68KW AC, WITH 19 MODULES (VBHN330SA), 10 DUAL MICROINVERTERS (CP-720),  AND A NEW SUBPANEL RATED AT 125A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32781	19041-20000-16371	10746 W FRANCIS PL	90034	5	117B161    11	4252032013	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			05/02/2019 12:00:00 AM			PC Info Complete	05/02/2019 12:00:00 AM	ADDRESS	34.02107	-118.41065	T24 ONLY PLAN CHECK FOR EXISTING APARTMENT BUILDING FOR LIGHTS AND OUTLETS ONLY, FOR OUTDOOR POOL AREA. TOTAL SQUARE FOOTAGE = 8677SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32782	11041-20000-15004	600-606 S LA BREA AVE	90036	4	135B181   585	5507023026	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.06474	-118.34381	Plan check power and energy for new 4-story mixed-used building with 2 residential dwelling units. New 800A overhead service supplying building. Retail spaces TI on seperate permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32783	19041-20000-21181	14006 W RIVERSIDE DR UNIT 25	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	08/28/2020 12:00:00 AM	ADDRESS	34.15713	-118.43792	Power, lighting, and distribution for change of use from retail to fitness center.  Plan check for power and energy.  BLDG #19016-20000-16753	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32784	19041-20000-28824	10700 W SANTA MONICA BLVD ste 309	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.05167	-118.432	change of use fron retail to medical office.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32785	11041-10000-25021	6873 N TROOST AVE	91605	6	183B169   436	2320011015	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Expired	12/16/2013 12:00:00 AM	ADDRESS	34.19599	-118.38665	"NEW WAREHOUSE <ADDITION & ADD MASONY WALLS AROUND EXISTING ""40'X42' WASH BLDG. PER C of  O UNDER #71LA23102>>;SERVICE  AND PANEL  B ARE EXISTING.PLAN CHK IS FOR TITLE 24 ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32786	17041-10000-43759	2719 W MARTIN LUTHER KING, JR BLVD	90008	10	114B189   292	5034009077	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	34.01095	-118.32279	REMOVE OUTDOOR METAL HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32787	16041-20000-29048	225 N CAROLWOOD DR	90077	5	141B157   408	4358005027	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.08188	-118.42612	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32788	17041-10001-13976	15739 W VENTURA BLVD	91436	5	168B141   612	2261009012	C4-1L, R1-1, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.15563	-118.47654	REVISIONS TO PERMITTED SET OF PLANS TO INCLUDE CHANGES DURING CONSTRUCTION:ADDED SUMP PUMP AND PUMPSTATION TO  MSA ; NEW A/V PANEL AND CIRCUITS TO DB1;REVISIONS TO LIGHTING SYSTEM.ALL CHANGES ON THE PLANS ARE CLOUDED.((((((((PC FOR ENERGY AND POWER.  NEW MULTIPURPOSE 3-STORY COMMERCIAL BUILDING. SERVICE 2500 AMP, 120/208 3 PHASE. TOTAL AREA  16720 FQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32789	14041-10000-01829	4549 W BRAZIL ST	90039	13	165B201   209	5593010018	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.14693	-118.27414	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 1100 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32790	16041-10000-18144	14645 W GAULT ST	91405	6	183B149   138	2219007035	(T)(Q)RAS3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			05/24/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.19948	-118.45246	Installation of fire alarm system in new 5 story 70 unit apartment building.  250 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32791	12041-20000-14947	3183 W WILSHIRE BLVD 1-449	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM			PC Approved	07/27/2012 12:00:00 AM	ADDRESS	34.06196	-118.29111	Remodel to Yogurtland in the existing building space (suite 181).  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-17641	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32792	09041-30003-08041	241 S DETROIT ST	90036	5	135B181    68	5513021028	RD6-1	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM			PC Approved	01/08/2010 12:00:00 AM	ADDRESS	34.06971	-118.34525	Supplemental is for changes to previously approved plans.  Feeder schedule was changed to match as-built and inspector field requests.  All changes were clouded and compared to original approved set.  P/C is for Power only.  ::  TI in an existing 3 story School.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32793	13041-20000-23736	6041 N ROD AVE	91367	3	177B085   325	2032020013	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.18065	-118.66218	pv1 single family dwelling using 6kw ac using 32 modules. transformerless inverter nonstandard plan. 4 strings/inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32794	10041-10000-21829	1129 S BOYLE AVE	90023		123A221   271	5170008014	MR2-1		Boyle Heights	Boyle Heights			Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM			PC Approved	11/02/2010 12:00:00 AM	ADDRESS	34.03059	-118.2205	CHANGE OF USE FOR 145' X 68' [IRREGULAR], GROUND-FLOOR PORTION, OF EXISTING 2-STORY, 274' X 148' [IRREGULAR], TYPE III-B, WAREHOUSE AND OFFICE BUILDING INTO CELLPHONE/ELECTRONIC PARTS ASSEMBLY/MANUFACTURING WITH ACCESSORY WHOLESALE DISPLAY AREA AND OFFICE. PLAN CHK IS FOR TITLE 24:PERMIT OBTAINED ON 10041-10000-11509	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32795	19041-10001-05722	10141 N LARWIN AVE UNIT   4	91311	12	204B101   228	2724003***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM			PC Approved	05/17/2019 12:00:00 AM	ADDRESS	34.25471	-118.61641	PLAN CHECK FOR ROOF MOUNTED 5KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 20 PANELS USING P400 OPTIMIZERS ALL FEES PAID UNDER ORIGINAL PERMIT 19041-90000-05722  Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32796	15041-10000-37894	11626 N HERRICK AVE	91340	7	213B157   282	2524019020	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM			Corrections Issued	11/10/2015 12:00:00 AM	ADDRESS	34.28158	-118.42569	PV1, SOLAR ROOF MOUNTED SYSTEM WITH MICRO INVERTERS, TOTAL SIZE 4.3KW. (10) PHONE SOLAR PS240P-20/U(10) ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32797	18041-10000-42833	4270 W 6TH ST	90020	4	135B189   887	5504009025	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.06335	-118.31751	REMOVE OUTDOOR HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32798	18041-20000-41919	11648 N PALA MESA DR	91326	12	213B121   162	2822030019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.28286	-118.55107	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32799	13041-20001-35492	13242 W BOMBAY ST	91342	7	225B157   515	2512022027	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	12/30/2013 12:00:00 AM	ADDRESS	34.31321	-118.42094	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NNONSTANDARD PLAN 3 STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32800	13041-10000-13785	9466 W REMBERT LANE	90210	5	150B165    44	4388009022	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.11125	-118.4014	PV1 13.25KWDC MICROINV 2STORY HOUSE. NONSTD. ROOFMOUNT.[ 53 MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE:  TRINA TSM-250PA05]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32801	19041-10000-04466	1130 W C ST	90744	15	027B201    90	7417008038	M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM			PC Info Complete	04/15/2019 12:00:00 AM	ADDRESS	33.77182	-118.27581	FULL PLAN CHECK FOR POWER AND ENERGY FOR WAREHOUSE ADDITION. SCOPE OF WORK INCLUDES NEW 5000AMPS SERVICE, 277/480 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 20637 SQFT NEW LD# 18014-10000-04977	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32802	12041-20002-15236	1751 S WESTWOOD BLVD	90024	5	129B153   370	4324028047	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM			PC Approved	02/02/2013 12:00:00 AM	ADDRESS	34.05089	-118.43821	Modification to previously approved set of plans located in a METHANE ZONE.   Change to lighting, relocating equipment, revised emergency lighting, new 80HM equipment.  PLAN CHECK ONLY.<<<<T.I. change use from retail to grocery store (Sprouts) in an existing building.  Relocate panel, add new branch circuits, and lighting.  Plan check for power and energy.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32803	19041-20000-11800	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.25052	-118.51258	PV1.  Installation of 9.6 kW roof mounted grid tied PV system.  (32) modules with 7.6 kW rated string inverter.  (E) 7 kW rated PV system also on site and using same interconnection.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32804	14041-10000-23469	735 S GAFFEY ST	90731	15	015B197   599	7454001006	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	33.73739	-118.29253	Power and energy plan check for  a TI  car wash comercial building with all new electrical service and equipment. cra cleared through building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32805	18041-10000-32384	9344 W NIGHTINGALE DR	90069	4	150B169  1271	5561009037	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Issued	11/05/2018 12:00:00 AM	ADDRESS	34.10472	-118.39132	PLAN CHECK FOR 11.4KVA ROOF MOUNTED PV SYSTEM - SYSTEM CONSIST OF 1 CENTRAL INVERTER(SE 1140A-US) WITH 40 MODULES USING (P505) OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32806	19041-20000-26147	23757 W HARTLAND ST	91307	12	183B089   655	2034031040	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.19437	-118.64447	PV1 PLAN CHECK FOR ROOFTOP MOUNTED PV SYSTEM. SYSTEM SIZE IS 10.395KW DC/10KW AC. SCOPE OF WORK INCLUDES (33) HANWHA Q CELL PV MODULES WITH P320 OPTIMIZERS AND A SE10000H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32807	11041-10000-08690	600 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM	05/06/2011 12:00:00 AM		Permit Closed	10/17/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	FIRST TIME TENANT, IN AIRPORT TERMINAL 6 FOR ALASKA AIRLINES.  NEW RESTAURANT WITH FULL PLAN CHECK.  APPLICATION  09041-10000-24074 HAS THE PREVIOUSLY APPROVED LOAD CALCS FOR REFERENCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32808	13041-10003-32351	1026 S BROADWAY BLDG A	90015	14	126A209   140	5139014006	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/14/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	ADDRESS	34.04029	-118.25788	FIELD CHANGES DURING CONSTRUCTION: ADDED FEEDER AND ATS  TO SUPPLY 5 HP EXHAUST FAN  IN THE GENERATOR ROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32809	15041-20000-42894	618 E 27TH ST	90011	9	120A207   385	5128012009	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	02/06/2016 12:00:00 AM	ADDRESS	34.0212	-118.26335	PV1.  Install 3.24 kW roof-mounted, utility-interactive PV system.  (12) SunEdison 270 modules with Enphase M215 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32810	13041-20000-28148	8041 N BOBBYBOYAR AVE	91304	12	189B093   162	2020020010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.21644	-118.63354	PV1 SINGLE FAMILY DWELLING. THIS IS ADDITION TO EXISTING INSTALLATION. NEW ADDITION INCLUDES NEW 20 MODULES, POWER ONE PVI-4.2 KW AC TRANSFORMERLESS INVERTER. NEW PV SUBPANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32811	14041-10000-14874	12690 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	33.97692	-118.41538	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32812	16041-10000-21358	8461 W MELROSE PL	90069	5	141B173   423	5528001054	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Issued	07/12/2016 12:00:00 AM	ADDRESS	34.08374	-118.37539	Plan check for Title 24 only.T.I. to (e) retail store (1,623 sf) to include interior remodel and exterior fa�ade remodel.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32813	14041-20000-23361	21725 W VICTORY BLVD	91303	3	180B105    77	2139004045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.18791	-118.60217	TENANT IMPROVEMENT FOR A NEW CONSTRUCTION.  OPEN BAR INSIDE A NORDSTROM RETAIL STORE.  ADDING AND MOVING LIGHTING FIXTURES.  USING EXISTING EQUIPMENT.  4275SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32814	16041-20003-24899	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	33.93576	-118.3779	changes to an approved set of plans.  changes noted delta 8.  changes include movement of branch circuits and removal and recalculation of light fixtures. this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32815	11041-10001-16279	2130 E 1ST ST	90033	14	127-5A223 122	5183008901	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM			PC Approved	01/23/2012 12:00:00 AM	ADDRESS	34.04433	-118.21291	changes to approved set of plans: inverter rating decreased from 12kva to 10 kva; added drawing for 1st floor showing how an exit sign was to be mounted TENANT IMPROVEMENT; CORE AND SHELL ON SEPARATE APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32816	12041-10000-03981	18647 W DEVONSHIRE ST	91326	12	204B121    71	2728028023	(Q)C2-1VL, C2-1VL, QC2-1VL	North Valley	Northridge			1112.03	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	PIN	34.25808925	-118.53932955	ALTERATIONS IN A WEIGHT WATCHERS STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32817	16041-10001-37492	200 WORLD WAY T2 LEVEL 4	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA DCN-014 ON PLANS. UPDATED LIGHTING SCHEDULE, T24 AND PANEL SCHEDULE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32818	19041-20000-20882	2249 S OVERLAND AVE pv1	90064	5	126B157   200	4320006090	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.04471	-118.42727	pv1instalkl roof moiunted pv system sized 9.5KW AC interconnected with msp.(1) tesla powerwall ESS rated 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32819	16041-10000-26325	1603 E 53RD ST	90011	9	108B213   128	5105001019	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	33.995	-118.2453	PV1 roof mounted solar system installation to a single family home. Installing (12) microinverters M250-60-2LL rated at 250 watts each for a total system size of 3.0 kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32820	14041-20000-24843	7006 S HOOVER ST UNIT 4	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #4.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32821	15041-10000-18597	125 S SAN PEDRO ST	90012	14	130-5A213 177	5161016014	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.04999	-118.24152	TENANT IMPORVEMENT AT THE OU BEAUTY SALON.PLAN CHK IS FOR TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32822	13041-10000-02652	12000 W HUSTON ST	91607	2	168B165   251	2355010047	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.15929	-118.39478	PV1 OTC PLAN CHECK FOR SINGLE STORY HOUSE.  17 MODULES {REC: REC 245 PE}  17 MICROINVERTERS: {ENPHASE M215-60-2LL-S22/S23}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32823	13041-20000-29678	333 S GRAND AVE 9TH FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	T24 PLAN CHECK AND PERMIT FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON THE 9TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32824	16041-10000-35230	3025 N NORTH BROADWAY	90031	1	138A223    33	5208003025	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.07389	-118.20937	NEW LIGHTING FOR FINANCIAL INSTITUTION. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32825	12041-20000-20569	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.24317	-118.50383	Service upgrade at existing building, provide feeder services to two other existing buildings, and install photovoltaic systems to the new service equipment.  plan was approved earlier, but modification were required due to DWP renovation requiements.  Fees for modules were covered under previous submittals (12041-20000-10456).  Fees for other structures shall be calculated when full plan check information is provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32826	13041-10008-07125	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			02/04/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.04594	-118.25757	Change to approved set by modifying the floor plan. Minor receptable and lighting load also being adjusted with NO NEW CIRCUITS added. All changes are under delta_23 and 24 only.(((7-STORY MIXED USED BUILDING 700 UNIT APARMENT, OVER 2-LEVEL SUBTERRANEAN GARAGE :  upper 6 levels residential and retail/gym on the 1st floor. None highrise.. 5000A SERVICE;__this note : by Nabil, this methane zone.  was indicated the level changed from 5 to 2.  see plan number 12041-10000-29828)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32827	13041-20000-03498	12412 W BLUFF CREEK DR BLDG 18	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	04/19/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	33.97709	-118.40692	PLAYA VISTA.  Methane zone.  First time tenant full plan check.  Low-rise office building.  Building #18.  All conduit for this project is above the membrane.  For methane details see Building #17 on 12041-10000-02932.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32828	16041-20000-02112	11461 W SUNSET BLVD 3rd Floor	90049	11	138B145   318	4429031007	QR4-1VL, RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.07213	-118.4684	Plan check for Title 24 only. Project site is an existing commercial building (hotel). Project scope is a tenant improvement. Total lighting area = 964 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32829	13041-10000-34169	547 S WESTERN AVE	90020	4	135B193   818	5503018019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.06397	-118.30938	PLAN CHECK FOR T24 ENERGY ONLY. BEAUTY SALON. 1132 SQFT. EMERGENCY LIGHTING. > 400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32830	18041-20000-38171	4803 N GLENALBYN DR	90065	1	148-5A223  45	5466030003	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM			Reviewed by Supervisor	10/24/2018 12:00:00 AM	ADDRESS	34.10313	-118.21134	install battery 36KWh to an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32831	15041-10004-37324	5700 N SEPULVEDA BLVD	91411	4	174B145   295	2243004010	(T)(Q)RAS4-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.17405	-118.46591	Supplemental PC for 20 new circuits and changes in T24. All changes clouded under delta 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32832	10041-20000-08801	21031 W VENTURA BLVD 6th fl	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	07/14/2010 12:00:00 AM	PIN	34.16717222	-118.59179488	energy for bath room lights 6th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32833	17041-10000-38370	6171 N SEPULVEDA BLVD A-4	91411	6	177B145   355	2242001015	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.18246	-118.46651	FULL PC FOR POWER AND ENERGY FOR A NEW RESTAURANT. FIRST TIME TENANT FOR A ONO HAWAIIAN BBG RESTAURANT.SCOPE INCLUDES NEW LIGHTS, NEW RECEPTACLES. TOTAL AFFECTED AREA IS 1900 SQ. FT.  B#17016-10000-31533	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32834	11041-20000-20016	21021 W VENTURA BLVD	91367	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	09/20/2011 12:00:00 AM		Permit Finaled	09/28/2011 12:00:00 AM	PIN	34.16705846	-118.59120236	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING 1ST FLOOR LOBBY AND CORRIDOR AREA.  PERMIT FOR EXISTING CKTS NEW FIXTURES AND DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32835	11041-10001-10090	10327 W SANTA MONICA BLVD	90024	5	132B157   401	4327017014	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Public Safety Only			06/08/2011 12:00:00 AM			PC Approved	06/08/2011 12:00:00 AM	PIN	34.05913764	-118.42238861	Revision to the approved fire alarm plan.  (((((((((((((INSTALLATION OF A FIRE WARNING SYSTEM INSIDE THE PARAMOUNT RECORDING STUDIO)))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32836	13041-20000-18534	1180 E 58TH ST	90011	9	108B209  1379	5104031013	MR1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	33.99007	-118.25445	Plan check for energy only. Fire damage of welding shop. Non-hazardous.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32837	19041-20000-04431	11538 W VICTORY BLVD	91606	2	180B169  1177	2335026015	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	04/08/2021 12:00:00 AM	ADDRESS	34.18644	-118.38367	Plan check for the installation of exit signs/unit equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32838	13041-20000-09822	9727 S LAUREL PL	90002	15	093A217   176	6046019903	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2421.00, 2422.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Expired	05/12/2015 12:00:00 AM	ADDRESS	33.94753	-118.2311	Install a new 600 amp feeder to new disconnect switch in  Retail (ROSS) Electrical Room.  No load is to be connected to the feeder.  Full plan check will be required for the tenant loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32839	18041-10001-33131	4806 N SYLMAR AVE	91423	4	169-5A151 209	2248004018	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			04/17/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	PIN	34.15792067	-118.44633889	PC only delta B, change to an approved set. service switchboard has been moved to 1st Flr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32840	15041-10000-22299	4845-4859 W FOUNTAIN AVE	90029	13	147B197  1088	5543019009	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.09551	-118.29518	PC FOR POWER.   REPLACING SERVICE WITH NEW 120/240 3PHASE 4 WIRE. 18 NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32841	13041-10000-25771	10990 W WILSHIRE BLVD #200	90024	5	132B149   138	4324002***	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.0577	-118.44711	PC FOR ENERGY ONLY. TI TO (E) OFFICE.  HIRISE. HAS GEN.# 200 (MOTION Recruitment - One Westwood)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32842	14041-10000-34916	12746 W JEFFERSON BLVD bld-2-Ste-2200	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM			PC Approved	12/19/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	Energy plan check for an office T.I  (indoor and outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32843	12041-10000-28786	11111 W SANTA MONICA BLVD ste 150	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM			PC Info Complete	12/24/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	T.I. On the ground floor for a high rise building.  Project is converting office space into a gym.  Change of use is triggered.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32844	15041-10000-11852	330 S SANTA FE AVE 0FL	90013	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	34.04513	-118.23241	PC FOR POWER AND ENERGY. FOUR STORY BUILDING. FIRSTTIME TENANT RETAIL STORE(VOYAGER). TOTAL AREA 1286 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32845	13041-20000-35919	7044 N BABCOCK AVE	91605	2	183B161   316	2324032020	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.19893	-118.4072	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING 12 MODULES. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32846	13041-10001-33004	1954 S FEDERAL AVE	90025	11	126B149  1051	4261026019	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.0386	-118.44855	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 4.25KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(17) TRINA SOLAR # TSM-250(17) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32847	15041-20000-24276	2149 E SACRAMENTO ST	90021	14	123A217   222	5166005008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.0307	-118.22825	Plan check Title 24 only for existing office space and industrial. Total indoor area:  5,679sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32848	19041-20000-47856	13817 W CUMPSTON ST	91401	4	174B153  1154	2247013070	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.16957	-118.43405	PV1. INSTALL 15.180 KW DC PV SYSTEM WITH (46) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32849	10041-20000-17041	6061 N TOPANGA CANYON BLVD	91367	3	177B101   111	2146025005	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.18066	-118.60615	Revision to approved plan  and existing permit # 10041 20000-13590. Change was to show power plan as installed per inspector request. Plan check T-24 Energy (general/emergency) lighting for existing Chevron  gas station. Supplimenting also 10041 20000 15655 for adding  page E-1 to complete plan as built running a conduit for low voltage camera and for sensor at the pump. UPGRADING SEVICE TO 400AMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32850	13041-10000-06860	20832 W VALERIO ST #22	91306	3	186B109  1048	2113013***	(Q)RD2-1, (Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.20456	-118.58754	photovoltaic system for single family dwelling. zoned as a condo. total system size 4.4 kw. using 18 panels. non standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32851	17041-10000-12049	1263 S WESTCHESTER PL	90019	10	129B189   916	5081020022	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	04/22/2017 12:00:00 AM	ADDRESS	34.04776	-118.31885	PV INSTALLATION OF NEW 10.35 KW AC SOLAR SYSTEM ON A SINGLE FAMILY HOUSE. (30) AC modules SUNPOWER SPR-X2-345-C-ACSYSTEM IS ROOFTOP SOLAR	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32852	18041-20000-04056	1318 W MARYLAND ST	90017	1	132A207   186	5152002009	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Apartment			02/02/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.05595	-118.26163	Plan check for power only. Project site is an existing 3-story, 30-unit apartment building. Project scope is a complete remodel. Work includes a new 800-amp service and a complete rewire of all units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32853	14041-20000-16764	15760 W VENTURA BLVD suite 110	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check for energy only. High rise office building, office remodel on the 1st floor. All lights and circuits are existing, just relocated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32854	14041-20000-32641	169 N LA BREA AVE UNIT A	90036	5	138B181   487	5513002015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.07563	-118.34423	PER APPLICANT. TENANT LOCATED AT END OF MAIN SERVICE BUS. INSPECTOR TO FIELD VERIFY TOTAL BACKFEED ON MAIN SERVICE. PER APPLICANT, NO OTHER PV SYSTEM ON SERVICE. PV2. ROOFMOUNTED SOLAR SYSTEM. (3) 1-PHASE TRANSFORMERED INVERTER. SYSTEM SIZE: 7500 W DC/ 9KW AC(33)SLK60PL  MODULES (3)  SMA 3000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32855	13041-10000-03859	3154 N CARLYLE ST	90065	13	150B213   508	5456008005	R2-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.10741	-118.23435	photovoltaic system for single family dwelling. SYSTEM SIZE 5.52KW. USING 24 TRINA SOLAR TSM 240PA05 SOLAR PANELS. USING SOLAREDGE SE6000A-US CENTRAL INVERTER. USING TRANSFORMERLESS INVERTER. USING POWER OPTIMIZER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32856	19041-10000-24944	11175 W SANTA MONICA BLVD 7TH FLR	90025	5	129B149   297	4324035029	M1-2	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	02/06/2021 12:00:00 AM	ADDRESS	34.04739	-118.44609	ENERGY PC FOR OFFICE TENANT IMPROVEMENT OF FULL 7TH FLOOR (10,931 SF).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32857	17041-10000-21966	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Issued	06/29/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	SERVICE RECONNECT FOR 5000A BUS DUCT REPLACEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32858	11041-10000-02184	10861 W LINDBROOK DR	90024	5	132B153   205	4360002032	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	05/24/2011 12:00:00 AM	ADDRESS	34.06023	-118.44294	T.I. for existing restaraunt.  1900 sgft Restaraunt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32859	12041-10002-05590	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	(T)[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.09787	-118.31961	Revision to the approved plan. Change the size of the Lift#1. EPC is for the change. ((((((((((((1200 A temp.construction service)))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32860	16041-20002-34801	9310 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.23949	-118.53589	[[[7/19/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO LIGHTING. CHANGES ARE CLOUDED. ]]]]changes to an approved set of plans. changes noted delta 1.  changes include different light fixtures and energy calculations.  this is plan check only.PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR RESTAURANT. 2584 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32861	16041-20000-04750	118 N DILLON ST	90026	13	138A201   177	5156010012	RD2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	02/14/2022 12:00:00 AM	ADDRESS	34.0727	-118.28265	Plan check for energy for (N) 200A service for exterior parking lot.  6600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32862	14041-20001-06036	4912 N PLACIDIA AVE	91601	4	168B177   221	2420011014	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM			PC Approved	03/16/2014 12:00:00 AM	ADDRESS	34.15989	-118.35593	(((Expedite fees)))PV1 ROOFTOP TRANFORMERLESS SYSTEM. USING COMBINER BOX. TOTAL SYSTEM SIZE 5.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32863	14041-20000-11616	20004 W PARTHENIA ST	91306	3	195B113   592	2782012010	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Expired	06/07/2016 12:00:00 AM	PIN	34.22770499	-118.56903649	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS INVERTER. SYSTEM SIZE: 6 KW DC.(24) HYUNDAI M250(1) POWER-ONE PVI-6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32864	18041-20000-42114	4747 N DON PIO DR	91364	3	168B105   801	2171021045	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.15401	-118.60393	Plan check for PV roof mounted system, System size: 10.0KW AC, 9.76KW DC with 32 PV Modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32865	19041-20000-15366	555 S FLOWER ST 35th flr	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	ti to an existing high rise building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32866	15041-20000-41465	8734 N GLENOAKS BLVD	91352	2	195B177   523	2404009021	C2-1VL, R1-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.03	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM			PC Approved	12/14/2015 12:00:00 AM	ADDRESS	34.22834	-118.36472	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (NAIL SALON). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 1577 SQ. FT.PERMIT FEES PAID UNDER PCIS#15041-20000-35673	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32867	13041-10000-26021	12665 W VILLAGE LANE	90094	11	105B161  1220	4211034054	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/03/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	33.97786	-118.41484	PLAN CHECK FOR POWER AND ENERGY. THIS IS BLOCK 5 OF PLAYA VISTA PROJECT. ELECTRICAL INSTALLATION FOR MULTI-FAMILY 4-STORY OVER PODIUM; 4 SERVICES (SERVICE 1,2,3,4), LOCATED IN METHAN ZONE,LEVEL 2.  (2) GENERATORS INSTALLED. TOTAL 491 UNITS. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM FROM PLAN HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32868	16041-10001-37864	6124 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Approved	03/20/2017 12:00:00 AM	ADDRESS	34.09782	-118.32339	03/20/17Changes to reflect what is on the field per inspector's request. Revising single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32869	19041-10000-23940	18362 W OXNARD ST BLD. 2	91356	3	177B125   753	2157002134	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Issued	11/08/2019 12:00:00 AM	ADDRESS	34.17985	-118.53311	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 1200A SERVICE 120/208V AND ASSOCIATED EQUIPMENT - TOTAL NEW CONNECTED LOAD OF APPROX. 400A. TOTAL AFFECTED AREA 307 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32870	19041-10000-28609	708 S BROADWAY	90014	14	127-5A211  64	5144015053	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.0448	-118.2535	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32871	14041-20000-22208	5420 S MCCONNELL AVE	90066	11	102B157    32	4211009018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	33.97813	-118.41955	TITLE 24 FOR  TENANT IMPROVEMENT OFFICE .  INSTALLATION OF NEW WIRING,  OUTLETS & LIGHTS.  PLAN CHECK BASED ON 2008 ENERGY CODE DUE TO BUILDING PERMIT SUBMITED BEFORE JULY 1ST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32872	13041-10000-25927	6529 N AGNES AVE	91606	2	180B165   503	2322008033	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.18942	-118.39552	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL IN A 2-STORY HOME. SYSTEM SIZE IS 4KW DC.TRANSFORMERLES SYSTEM. (16)MODULES: TRINA-SOLAR-TSM-250PA05.18(1)INVERTER: AURORA-PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32873	17041-20001-05571	17270 W DEVONSHIRE ST	91325	12	204B133   195	2694015006	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			Reviewed by Supervisor	03/03/2017 12:00:00 AM	ADDRESS	34.2574	-118.51061	PV1.  Install 13.86 kW roof mounted grid tied PV system.  (44) modules with (2) 6.6 kW rated central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32874	15041-10000-11256	11640 W SAN VICENTE BLVD 108	90049	11	129B145    21	4265005022	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.05369	-118.46307	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1685.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32875	16041-10000-18564	3812 W OAKWOOD AVE	90004	13	138B197    84	5501001023	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM			Reviewed by Supervisor	06/08/2016 12:00:00 AM	ADDRESS	34.07761	-118.28979	PV1, NSTALL NEW 11.28 KW DC ROOF-MOUNTED SOALR ARRAY ON A SINGLE FAMILY HOUSE.(41) MODULES:SOLARWORLD SW 275 MONO BLK(41)MICROINVERTERS: ENPHASE ENERGY M250-60-2LL-S256/22/16: Status changed to PC only, permit will be pulled under different PCIS#, rthat's PC by John Hua (DM)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32876	18041-10000-08762	9760 W PICO BLVD	90035	5	129B165  1239	4307004***	C4-1VL-O, R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.05401	-118.40151	PC FOR A FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES ADDING/REPLACING 95 FA DEVICES AND 5 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32877	16041-10003-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	01/04/2017 Changes to aa approved set of plans Changes include relocation of panels and addition of lighting and equipment in EDS machine room 9 new circuits for CTX PLC and 3 equipment for CTX machine. Changes has been clouded as DCN- 17 only. 1/4/2017CHANGES TO THE APPROVED SET OF PLAN. CHANGES UNDER ADD-006 INCLUDING RELOCATING SOME CIRCUITS AND FIXTURES AND ADDITION OF 2 MORE FIXTURES AND 8 NEW CIRCUITS.----PLAN CHECK FOR POWER AND TITLE-24BUILDING PERMIT #16016-10000-11862SCOPE OF WORK DENOTED BY DASHED AND SOLID LINES.  FACILITY IMPROVEMENT FOR TERMINAL 2 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUS OPERATION, AND OFFICE RENOVATION.  17 NEW PANELS TIED IN TO EXISTING POWER DISTRIBUTION SYSTEM WITH ASSOCIATED LIGHTING AND EQUIPMENT.-----	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32878	14041-20000-09238	706 N CITRUS AVE	90038	5	141B185   553	5524012022	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.08374	-118.33955	PLANCHECK FOR T24 ENERGY ONLY PER INSPECTORS REQUEST. 2 STORY COMMERCIAL OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32879	14041-20000-21545	11374 N FERRARA LANE	91326	12	213B109    70	2701049030	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.27819	-118.58063	pv1 sfd. total system size 7.8kw AC using 2 transformerless inverters. nonstandard plan. derrating main breaker. total of 37 modules. connect to center fed bus	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32880	12041-10000-22655	2825 W 8TH ST	90005	1	132B197   413	5077019007	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			09/24/2012 12:00:00 AM			PC Approved	09/24/2012 12:00:00 AM	ADDRESS	34.05786	-118.28756	TENANT IMPROVEMENT IN A BOARDING HOME ON THE 2ND FLPLAN CHK IS FOR TITLE 24 FOR LIGHTING FIXTURES IN THE HALLWAY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32881	17041-20000-22825	23634 W DRACO WAY	91307	12	186B093   629	2027014013	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.20285	-118.64154	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32882	17041-10000-31111	8128 S NORMANDIE AVE	90044	8	099B197  1245	6033005020	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	33.96467	-118.30008	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 5KVA CONSISTING OF 18 MODULES/POWER OPTIMIZERS(SOLARWORLD/SOLAREDGE P320) WITH 1 CENTRAL INVERTER(SOLAREDGE SE5000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32883	15041-10000-07936	7055 N SOPHIA AVE	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.20003	-118.4871	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 11616 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32884	12041-20003-23469	11831 W VOSE ST	91605	2	183B169   185	2321004004	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.19855	-118.39129	"((Changes made to approved set. Changed feeder type from CU to AL. NO CHANGES TO LOADS HAVE BEEN MADE))Changes to previously approved set of plans. 3000A 480 3-phase service changed to a 800A 3-phase delta service. Changes to voltage drops and fault current, all equipment inside building is the same as previously approved.  Plan Check Only for ""DELTA B"" Changes on page E2.0 & E2.1.NEW WAREHOUSE / OFFICE BLDG -"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32885	17041-10000-05661	1135 N ALAMEDA ST	90012	1	135A215   338	5408029001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.06282	-118.23628	Plan check Title 24 only for T.I. for existing space, Total area: 1,433 sq ftB#16016-10000-13080	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32886	15041-20000-40620	6201 W HOLLYWOOD BLVD	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC FOR POWER. REMOVAL AND RELOCATING A 1000A BREAKER ON THE MAIN SWITCHBOARD. SCOPE INCLUDES A NEW 1000A METER BOARD WITH 6 NEW METERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32887	13041-10001-12515	819 S SANTEE ST	90014	14	126A211    46	5145013005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			11/18/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.04107	-118.25233	Change to approved set by replacing and adding new downlight to Ground Floor light plan only. All changes are under delta-2. Title 24 is resubmited.(((CHANGE OF USE OF AN EXISTING 93,379 SQFT, 13-STORY BUILDING W/ BASEMENT INTO JOINT LIVING AND WORK QUARTERS PER THE ADAPTIVE REUSE ORDINANCE.  (TOTAL 96 UNITS). fire alarm variance NEEDS TO BE FILED)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32888	18041-20000-26295	16033 W DICKENS ST	91436	5	168B141   651	2283011021	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.15504	-118.48249	Plan check for PV roof mounted system, with 8.19KW AC with 26 modules and 26 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32889	15041-20000-25836	1146 S WOOSTER ST	90035	5	132B169  1123	4332018012	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.05579	-118.38243	PV1 SFD TOTAL SYSTEM SIZE 4KW AC USING 16 MICROINVERTERS. ENPHASE M250.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32890	19041-10000-20512	1133 S BUNDY DR	90049	11	126B145    38	4264025023	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.04533	-118.46822	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32891	17041-20000-13622	22688 W FLAMINGO ST	91364	3	165B097   434	2078005018	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.14777	-118.62098	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 12.099 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32892	15041-20000-15477	4955 N VAN NUYS BLVD Ste 308	91403	4	169-5A151  13	2263026046	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.16078	-118.4489	Plan check for power and Title-24 (energy).  Total area = 1,838 sq. ft.  T.I. to medical office located in existing highrise building.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32893	10041-20000-19521	5060 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM			Reviewed by Supervisor	11/30/2010 12:00:00 AM	ADDRESS	34.02015	-118.35387	PLAN CHECK POWER AND ENERGY FOR RETAIL (ROSS) TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32894	14041-20000-17314	5700 W WILSHIRE BLVD 5TH FLOOR	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING. EXISTING HIGH RISE BUILDING RELOCATION OF LIGHT FIXTURES ON THE FIFTH FLOOR ONLY. PANELS ARE EXISTING WITH NEW BRANCH CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32895	17041-20000-07722	20725 W SESNON BLVD #247	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Expired	05/05/2024 12:00:00 AM				pv1install roof mounted pv system sized 3.2kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32896	12041-10000-07640	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check power for LAX Terminal 5 Primary switchgear and distribution (infracture upgrade). New equipment, switchboards, and panels. Existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32897	17041-20000-34189	15500 W VALLEY VISTA BLVD	91436	5	165B141   252	2285002037	R1-1	South Valley	Encino - Tarzana	Encino		1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.14955	-118.47273	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.162 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32898	11041-10000-15314	20914 W VENTURA BLVD	91364	3	171B109    95	2167024028	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Expired	08/14/2013 12:00:00 AM	ADDRESS	34.16626	-118.58903	T.I.  Existing 7-11.   Replacing 28 light fixtures using the existing branch circuits in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32899	15041-20001-16513	5901 W CENTER DR PHASE 1	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			10/27/2017 12:00:00 AM			PC Approved	11/03/2017 12:00:00 AM	ADDRESS	33.97509	-118.38703	10/27/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 7. Scope of changes is rearrangement and resizing of feeders for apartment units. *****Previous Work Description*****pc for power and energy. new apartment building, 5 story, 95 units. total area 60280 sq ft(unconditioned ) + 4365 sq (conditioned). PHASE 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32900	16041-20000-23215	920 W DOWNEY WAY BHE 310	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.02063	-118.28879	Plan check Title 24 only in existing space in USC BHE Lab 310 T.I. Total area: 466 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32901	19041-10001-00575	905 S VERMONT AVE	90006	10	132B197   834	5094026002	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM			PC Info Complete	02/26/2020 12:00:00 AM	ADDRESS	34.05569	-118.29192	Revision to an approved set , adding 100kw generator, adding panels and ckts and change to T24.Francis is the original plan checker************Original Scope***********FULL PLAN CHECK FOR POWER AND ENERGY FOR - NEW 7 STORY MIXED USE BUIDLING WITH 67 UNITS.  NEW 2000A SERVICE 120/208V 3 PHASE - TOTAL AFFECTED AREA = 42069 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32902	16041-10003-45243	8654 N MASON AVE	91306	3	195B109   357	2781007024	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Issued	01/24/2017 12:00:00 AM	ADDRESS	34.22794	-118.57961	01/24/16CHANGES TO AN APPROVED SET OF PLANS. PC AND PERMIT FOR AN ADDITION OF 2 MODULES. TOTAL SYSTEM NOW USES 22 MODULES. REPLACING CENTRAL INVERTER FROM A SOLAREDGE SE3800H-US TO A SOLAREDGE SE5000A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32903	15041-10000-24113	425 S PALOS VERDES ST	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	33.74102	-118.28156	PC FOR ENERGY. TI IN CORRIDOR FIRST FLOORAND SOME OFFICES IN SECOND FLOOR. TOTAL AREA 6368 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32904	18041-10000-07380	12051 W VENTURA BLVD	91604	2	162B165   105	2368002038	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Info Complete	03/12/2018 12:00:00 AM	ADDRESS	34.14376	-118.39488	PC for T24 only for replacement of indoor&outdoor existing fixtures with LED fixtures for Chase bank. Egress lighting is not part of the scope.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32905	16041-20000-29297	2250 E ALCAZAR ST ROOM 134B	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM			PC Approved	08/17/2016 12:00:00 AM	ADDRESS	34.06307	-118.2	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR USC CLINICAL SCIENCE CENTER. ROOM 134B. 968 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32906	15041-10000-27510	7199 W FORMOSA FUSION CT	90046	5	141B181  1707	5525003032	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08567	-118.34608	PV1 INSTALL NEW 2.KW DC SOLAR ARRAY ON A SINGLE FAMILY HOME.(8) MICRO INVERTER: ENPHASE M215-60-2LL-S22(8) MODULES: S-ENERGY S-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32907	14041-20001-04850	17151 W SIMONDS ST	91344	12	213B133   833	2697015015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.27655	-118.50672	Fee for expedite only*****Roof mounted PV system with 6.5KW dc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32908	14041-20000-02006	19553 W VALERIO ST	91335	3	186B117   622	2116003053	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Expired	04/18/2016 12:00:00 AM	ADDRESS	34.20443	-118.55976	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 9.8KWAC. 4 STRINGS FOR 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32909	14041-20000-07562	3005 W PEAK PL	90065	13	154-5A215 617		RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.1189	-118.2381	PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 1.3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32910	19041-10000-23254	8620 W MELVIL ST	90034	10	123B169   856	4312021005	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Issued	06/18/2019 12:00:00 AM	ADDRESS	34.03267	-118.38069	PV1 Rooftop solar system 6kW AC. Install (27) modules with (27) P320, (1) 6 kW inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32911	14041-10000-19385	10456 S VERMONT AVE	90044	8	090A199   143	6061003003	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.01	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM			PC Approved	07/18/2014 12:00:00 AM	ADDRESS	33.94126	-118.2914	Title 24 plan check only per inspector request.  Total area = 1,623 sq. ft. Lights are existing per applicant. Building application sumbitted before title 24 part 6 effective date. Permit obtained under 14041-70000-18564.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32912	19041-10000-07616	1055 W WILSHIRE BLVD	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.05232	-118.2629	NEW FIRE ALARM SYSTEM INSTALLED IN A CHURCH. SCOPE OF WORK INCLUDES NEW FA PANEL AND (53) FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32913	10041-10000-10002	705 W 9TH ST 1ST FLOOR	90017	9	129A207   265	5144021040		Central				2077.10	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM	05/26/2010 12:00:00 AM		Permit Expired	06/01/2022 12:00:00 AM	ADDRESS	34.04607	-118.2616	TENANT IMPROVEMENT OF COMMERCIAL SPACE IN A HIGH RISE RESIDENTIAL BUILDING ON THE FIRST FLOOR WHICH IS DESIGNATED FOR RETAIL TENANTSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32914	13041-10000-08388	2445 N METZLER DR	90031	1	139-5A227 238	5209012013	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	34.0748	-118.1981	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 5.76KW. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING TOTAL 24 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32915	18041-10001-16164	345 S GRAMERCY PL	90020	4	135B193   386	5504024082	R4-1	Central	Wilshire	Greater Wilshire		2117.03	Electrical	Electrical	Apartment			09/28/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	34.06755	-118.31312	INSTALLATION OF 42 STACK WASHER/DRYER UNITS-ONE IN EACH OF 42 UNITSPERMIT WAS OBTAINED BUT ADDED LOAD WAS GREATER THAN 400A.PLAN CHECK ONLY(((((((INSTALL WASH MACHINE RECEPTICLES EACH UNIT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32916	10041-20000-05435	8335 W MELROSE AVE	90069	5	141B173   436	5528003198	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM			PC Approved	03/25/2010 12:00:00 AM	ADDRESS	34.0838	-118.37143	"Lighting changes/ ""AS BUILD "" TO 10041-20000-00933Energy"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32917	17041-10000-27375	16106 W SHERMAN WAY	91406	6	183B141   126	2224009032	C2-1VL, [Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.20098	-118.48416	REPLACE EXISTING FIXTURES WITH LED - T24 ONLY. TOTAL SQUARE FT 10300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32918	16041-20000-21214	10341 W DIAMOND ST LOT 11	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32919	19041-10000-49987	3626 S 11TH AVE	90018	10	120B185  1364	5044010016	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Permit Finaled	02/05/2024 12:00:00 AM	ADDRESS	34.02211	-118.3294	FULL PLAN CHECK FOR A CHANGE OF USE. SCOPE INCLUDES NEW 600A, 120/240 3PH 4W AND HOUSE PANEL. TOTAL AFFECTED AREA IS 14237 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32920	14041-10000-01566	1515 N ECHO PARK AVE	90026	13	141A209   281	5419015002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.08039	-118.25525	T24 PART 6 ENERGY; LIGHTING UPGRADE TO (E) SINGLE STORY COMMERCIAL OFFICE SPACE. PROJECTED AREA IN LIGHTING WORK IS APPROX. 443 SQ FT AND INCLUDES EMERGENCY LIGHTING. SCOPE OF WORK < 400A. OUTLETS WILL BE RELOCATED ON (N) CKTS;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32921	12041-10000-12937	1257 N TIGERTAIL ROAD	90049	11	141B137   122	4493023020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.08037	-118.4885	New 14kw GROUND mounted photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32922	12041-10001-09412	19514 W ROMAR ST PV1	91324	12	204B117   406	2726015015	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.25435	-118.55841	PLAN CHECK FOR NEW ROOF MOUNTED 10.32KW PHOTOVOLTAIC SYSTEM.  ADDITIONAL MODULES ADDED TO SYSTEM. ORIGINAL APPLICATION WAS EXPRESS PERMIT, THIS PERMIT IS FOR THE DIFFERENT BETWEEN QUANTITTY OF MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32923	19041-20000-38663	3580 W WILSHIRE BLVD #400	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Info Complete	09/25/2019 12:00:00 AM	ADDRESS	34.06156	-118.3028	Plan check forTitle 24 energy only in existing space convert classrooms in to laboratories. Total area: 3512 sq ft. B#19016-30000-23111	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32924	13041-20002-33005	12100 N SALEM DR	91344	12	216B133   184	2606011028	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.29019	-118.50819	Changes from previously approved plans.  Changes include relocate panels on roof and relocate inverters.  Note: Permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.Previous Description:PV1, Install 8 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(2)Transformerless inverter(s): SolarEdge SE3800A-US. (32) modules: Trina Solar TSM-250PA05.18.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32925	18041-20000-14176	4870 N DON PIO DR	91364	3	168B105  1405	2171018093	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.15621	-118.60413	Plan check for PV roof mounted system, system size: 5.2kW with 17 modules and 1 inverter (5.2). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32926	19041-10001-42067	1742 W 84TH PL	90047	8	097-5A193 143	6034025020	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	05/06/2020 12:00:00 AM	ADDRESS	33.96169	-118.30836	EXPEDITE FEESPV2, NEW ROOFTOP MOUNTED PV SYSTEM, SYSTEM SIZE IS 25.2KWac/36.3KWdc. SCOPE OF WORK IS 99 MODULES (HIS-S370RI) ALL WITH OPTIMZERS (SE P400), LEADING TO THREE CEMTRAL INVERTERS (TWO SE7600H-US AND ONE SE10000H-US), LEADING TO A PV SUBPANEL, INTERCONNECTING TO AN EXISTING SERVICE (PLAN CHECKER TO VERIFY SERVICE SIZE AND FAULT CURRENT).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32927	15041-20000-29919	16744 W VENTURA BLVD	91436	5	168B137   323	2289020009	C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.15842	-118.49829	Title 24 plan check only.  Total area = 550 sq. ft.  T.I. to existing commercial space.  New lighting in 4 rooms of massage parlor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32928	16041-10001-16572	1150 S OLIVE ST 11TH FLR-LOBBY	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM			PC Approved	05/20/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	05/20/16CHANGES TO AN APPROVED SET OF PLANS. REMOVING/REPLACING LIGHTING FIXTURES. NOTE: ORIGINAL APPLICATION UNDER PCIS#16041-10000-16572(((((T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR AN EXISTING OFFICE ON THE 11TH FLOOR OF AN EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS ON THE ELEVATOR LOBBY AND BRIDGE. TOTAL AREA: 2,396 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32929	14041-20000-26985	14431 W CHATSWORTH DR	91340	7	210B149   254	2613022039	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	34.27453	-118.44799	PV1 SFD. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. TOTAL OF 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32930	18041-20000-17245	900 N NORTH BROADWAY # 1080	90012	1	135A215   238	5414013901	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.06408	-118.23726	Plan check for Title 24 only in existing spce T.I. retail space number: 1080. Total area: 1815 sq ft. B#18016-10000-09503	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32931	18041-20000-36155	14019 W VANOWEN ST	91405	2	183B153  1108	2216014012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Apartment			09/21/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.19407	-118.43864	New 3-story 5-unit apartment building with 600A 240/120V 1ph-3w service.  Plan check for power.  Building permit issued under 17010-20000-03262.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32932	19041-20001-18284	4915 W LOS FELIZ BLVD	90027	4	150B197   103	5588009007	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM			PC Approved	05/31/2019 12:00:00 AM	ADDRESS	34.11049	-118.2963	Expedite per applicant requestPlan check for PV roof mounted system, PV system size: 15.1kW AC, 15.9KW DC with 49 PV Modules and 2 inverters(7.6kW) connected to existing 400A Service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32933	19041-20000-34636	3030 N SURRY ST	90027	4	153A203   332	5434019010	R1-1	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.11201	-118.27395	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM AND ENERGY STORAGE SYSTEM TO EXISTING SFD. PV SYSTEM SIZE IS 4.32KW DC/ 7.6KW AC. ENERGY STORAGE SYSTEM SIZE IS 13.5 KWH. SCOPE OF WORK CONSISTS OF (12) PV MODULES WITH POWER OPTIMIZERS, A 5KW AUTO TRANSFORMER, A 13.5 KWH BATTERY, A 125A PANEL, AND A 7.6KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32934	11041-10000-01275	6100 W MELROSE AVE	90004	4	141B185   595	5523001017	C2-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	08/24/2011 12:00:00 AM	PIN	34.08320613	-118.33343965	INSTALL A NEW 14KW PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32935	13041-10000-28260	11261 W BLIX ST	91602	4	168B173   585	2353028021	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	34.15669	-118.37653	PV1 5.184KWAC. 240V. microinverter. STD. 1story. Roofmount. [(24) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(24)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32936	16041-20000-20217	1001 E 27TH ST	90011	9	118-5A209 206	5128024026	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Info Complete	08/11/2016 12:00:00 AM	ADDRESS	34.0184	-118.25652	Plan check for power and energy for fire damage church replace new service 800A new panels and associated  circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32937	14041-20000-02097	14145 W LOUVRE ST	91331	6	204B153   227	2617017021	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Expired	03/02/2016 12:00:00 AM	ADDRESS	34.25811	-118.44201	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan. ensure AFCI protection on DC circuits	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32938	13041-20000-25340	4832 N TUJUNGA AVE	91601	2	168B173   228	2353023019	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.1586	-118.37883	RENOVATION OF 2 CLASS ROOMS. RELOCATION OF LIGHTING DUE TO NEW WALL PARTITIONS. TOTAL AREA 1200 SQ FT. PERMI TO BE ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32939	18041-10001-18993	124 S CROFT AVE 1-4	90048	5	138B173   687	5511014007	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	11/30/2022 12:00:00 AM	ADDRESS	34.07387	-118.37406	Plan check for a lost set of plan. Permit is pulled and the permit is also being transfered to different contractor per owner request under this application.(((NEW FIRE WARNING SYSTEM FOR 5-STORIES APARTMENT BUILDING)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32940	17041-20002-19654	17909 W PALORA ST	91316	5	168B129   137	2182006018	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Issued	02/28/2018 12:00:00 AM	ADDRESS	34.15972	-118.52223	Revisions to approved set of plans.  Change of feeder rating to backup gateway and (1) additional Powerwall.  Total ESS size of 27 kWh.  (((Plan check for roof-mounted solar pv system with AC coupled battery backup system.6kW ungrounded system. (23) 325W pv modules. (1) 5kW Tesla Powerwall.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32941	11041-20000-21617	11601 W WILSHIRE BLVD 1900	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	PIN	34.0509267	-118.45996763	PLAN CHECK T24 ENERGY/EMERGENCY TENANT IMPROVEMENT TO 19TH FLOOR OFFICE. PERMIT FOR ON ELECTRICAL WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32942	18041-20000-15869	18417 W BRYANT ST	91325	12	195B125   940	2786004007	P-1VL, [Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.22749	-118.53447	New service and interior improvements for commercial laboratory space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32943	17041-10000-38268	1234 S DANIELS DR	90035	5	132A165   217	4330018005	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM			Reviewed by Supervisor	10/31/2017 12:00:00 AM	ADDRESS	34.05535	-118.40122	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH TESLA POWERWALL BATTERY.  TOTAL PV SYSTEM SIZE IS 5.2KWac WITH 5.8KVA 13.5 KWH STORAGE BATTERY.(10)MODULES-SOLARCITY STANDARD SC325(1)INVERTER-SOLIVIA 5.2 TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32944	15041-20000-29247	10903 N WHITE OAK AVE	91344	12	210B129   820	2712012014	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.26873	-118.52	PV1 roof mounted solar panel, transformerless, 7.41 kw system(26) microinverters: Enphase M250-60-230-522	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32945	14041-20000-07428	515 S OLIVE ST	90013	14	130-5A211 167	5149030001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.0491	-118.25342	Change of use from retail to barber shop.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32946	14041-10000-21169	11105 N MCVINE AVE	91040	7	210B193   439	2551045001	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			Verifications in Progress	09/19/2014 12:00:00 AM	ADDRESS	34.27066	-118.31163	PV1, INSTALL 4.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: TRINA SOLAR TSM-255PA05.18(1) INVERTER: SOLAREDGE SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32947	15041-10001-06855	10250 W SANTA MONICA BLVD #1045	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	PIN	34.0586034	-118.41904766	(((6/9/2015- CHANGES MADE TO APPROVED SET. CHANGED LIGHTING CONFIGURATION AND SOME OF THE LIGHT FIXTURES. T24 TO BE RE-VERIFIED)))new microsoft store at the century city mallPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32948	14041-20000-20004	16409 W GLEDHILL ST	91343	12	198B137   141	2676010019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.24214	-118.48964	New roof mounted PV system with total system size 3.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32949	18041-10000-17554	10601 W WASHINGTON BLVD 102.1	90232	5	117B165   262	4208009049	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.0175	-118.40491	PLAN CHECK FOR POWER AND ENERGY IN A NEW RESTAURANT. FIRST TIME TENANT. SCOPE INCLUDES ONE NEW 200A PANELBOARD, NEW CIRCUITS, AND NEW LIGHTS.  BUILDING PERMIT # 18016-10000-13069	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32950	15041-20000-22255	22436 W LASSEN ST	91311	12	201B101   227	2727004009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.24829	-118.61625	PV1. Install roof mounted PV system sized 8.0 kW. Interconnected with main service panel. (34) Kyocera KD265 Modules(1) SMA SB8000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32951	18041-10003-02660			12	201B097    78	2724009012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM			PC Approved	02/21/2018 12:00:00 AM	PIN	34.2477874	-118.62233832	PC FOR CHNAGES TO APPROVED SET UNDER DELTA 2. SCOPE INCLUDES REVISIONS TO ROOF LAYOUT TO REFLECT RELOCATION OF MODULES. THIS IS PLAN CHECK ONLY PEMIT PULLED UNDER MASTER. PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 11.4KVA CONSISTING OF 1 CENTRAL INVERTER(SOLAREDGE SE11400A-US), AND 35 MODULES WITH P400 POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32952	18041-30000-28747	10880 W WILSHIRE BLVD 7/8/9TH FL	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check for T24 only, TI on (E) Restroom on 7th, 8th, and 9th floor of the commercial building. Total area: 579 sq.ft. New lights are fed from existing circuits.B# 18016-10000-14959	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32953	15041-20003-17244	14861 W BESSEMER ST	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.18089	-118.45728	08-27-2015 Plan check for change to approved set of plans. Changes include addtion of receptacles and light fixture manufacturer. Changes apply to delta 1 only{{{{{{07-27-2015 Plan check for lost original set of plans, Title 24 only.[[[Plan check for retail T.I. Title 24 only. Total area: 2,042 sqft]]]]}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32954	19041-10000-07289	21050 W KITTRIDGE ST	91303	3	180B109   377	2148029022	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	34.19099	-118.5916	FULL PLAN CHECK FOR POWER AND ENERGY FOR New 7-story, 395-unit, Apartment building. 5 stories of TYPE IIIA over 2-story TYPE IA podium WITH 7 STORY TYPE IA PARKING STRUCTURE WITH ROOF TOP PARKING. SERVICE SIZE = (3) 4000A RATED AT 120/208V B# 18010-10000-04971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32955	10041-10000-04446	6310 W SAN VICENTE BLVD #285	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	06/08/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.06084	-118.36757	Plan check T-24 energy (general/emergency) lighting for suite 285. Not health care facility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32956	16041-10000-41796	10250 W SANTA MONICA BLVD # 1790	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time tenant ""Bacio di LAtte"" Ste. 1790.  Install 75KVA Xrfmr, new panels and its circuits, total effected area: 634 sq.ft.*New demand load 118 A ~~ MS ELA33"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32957	18041-20000-43809	1434 N POINSETTIA PL	90046	4	147B181   815	5548019032	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			11/15/2018 12:00:00 AM	08/04/2020 12:00:00 AM		Issued	08/04/2020 12:00:00 AM	ADDRESS	34.09685	-118.34819	800A 240/120V 3ph-4w service, distribution, power and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32958	17041-10000-45989	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Closed	02/09/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR TITLE 24 ENERGY ONLY FOR STARIWELL LIGHTS IN T-2 LEVEL 2 PUBLIC AND SUPPORT SPACE. SCOPE INCLUDES INSTALLING 7 NEW FIXTUES ON NEW EM. CIRCUITS. TOTAL  AFFECTED AREA 782 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32959	18041-20000-07220	2208 N STRADELLA ROAD	90077	5	153B145   195	4377030002	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.11283	-118.46263	PV1.  INSTALL ROOF MOUNTED PV SYSTEM AND 13.5 KWH ENERGY STORAGE SYSTEM - PV SYSTEM SIZE 6.6KVA CONSISTING OF 1 CENTRAL INVERTER(SOLIVA 6.6) WITH 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32960	13041-10001-27131	10921 N OSO AVE	91311	12	210B113   147	2707032010	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.26868	-118.57695	][][]EXPEDITED PER APPLICANT REQUEST [][][PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 225A MAIN; WORK DONE ON A NON-STANDARD PLAN. 5 TOTAL STRINGS; COMBINER BOX WILL BE USED, ALONG WITH A 125 LOAD CENTER; DC NEGATIVELY GRNDED, SYSTEM SIZE IS 16.75KW DC WITH (67) MODULES: TRINA #TSM-250PA05.18(2)FRONIUS #IG PLUS V 7.5(1)SHOALS# STG-CBRH-3-A COMBINER BOX; 3 STRING, 90A, 600V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32961	11041-10000-12760	299 WORLD WAY parking	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/05/2011 12:00:00 AM	ADDRESS	33.94454	-118.40534	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32962	13041-10000-29608	4831 W ST ELMO DR	90019	10	126B181   386	5067009034	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.0435	-118.34286	PV1.  Install 2.75 kW DC roof-mounted photovoltaic system, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3000A-US, power optimizer, and  11 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32963	16041-20000-20116	14909 W MAYALL ST	91345	7	204B149   396	2647003016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Expired	07/13/2018 12:00:00 AM	ADDRESS	34.25371	-118.45698	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.38 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32964	14041-10000-24377	5820 N MURIETTA AVE	91401	2	174B153   207	2246015003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.17636	-118.43871	Installation of roof mounted solar PV array.  Total system size = 6.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32965	16041-20001-44993	5400 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.06201	-118.34659	6.27.2017 - Plan check only for modifications to approved set. Mezzanine floor plan revised, relocate equipment, and update lighting plans/T24 forms. Rearrange roof equipment. Panel MA changed from (NEW) to (EXISTING). All changes clouded delta 2 and 3.======Plan check for power and energy. First time tenant - new restaurant. 5,459sqft.Note: Building application has been generated under 16016-10000-31045	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32966	16041-10000-15193	3036 S CRENSHAW BLVD	90018	10	120B185   733	5051029031	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Expired	06/18/2018 12:00:00 AM	PIN	34.02620528	-118.33468916	PC FOR T24 ENERGY ONLY. REPLACEING EXTERIOR FACADE. NEW CANOPIES AND CANOPY LIGHTING.*(2) unrelated trades: 15016-10000-04161, 16042-70000-06308	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32967	14041-20000-04649	10960 W WILSHIRE BLVD 19TH FLR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.058	-118.44597	T24 PART 6 ENERGY FOR (E) HIGH-RISE OFFICE BUILDING; NEW/EXISTING/RELOCATE LIGHTS; ADDING POWER, REUSE EXISTING CIRCUITS. SCOPE OF WORK < 400A. TI WORK PERFORMED ON 19TH FLOOR. PROJECTED AREA OF LIGHTING WORK IS APPROX. 2311 SQ FT. PLAN CHECK AND PERMIT UNDER SAME APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32968	16041-20001-28083	601 W 5TH ST Suite 600	90071	9	130-5A211  96	5151017029	C2-4, D	Central			YES	2075.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	02/24/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 forms.*****Previous Work Description*****TITLE 24 FOR EXISTING COMMERCIAL BUILDING T I AT 6TH FLOOR(SUITE 600).TOTAL AREA = 2949 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32969	19041-20000-06929	4808 N LEMONA AVE pv1	91403	4	168B145   440	2264022002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.15791	-118.45945	pv1install roof mounted pv system sized 9.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32970	17041-10001-39264	10250 W SANTA MONICA BLVD #1550 &-#S2455	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Approved	05/03/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"[This is plan check only, permit is covered under master permit# 17041-10000-39264]  Revision to approved plan, chnages noted as Delta-4 only: Add EMS and lighting Relay panels; revise single line diagram; revise panel schedule, revise power floor plan, revise lighting plan and T24 information accordingly.<<<Full plan check (Power+Energy), first time tenant ""COS"" ste#1550 and its storage space ste. #S2455, total of  (7) panelboards, transfomers (2)15KVA, (1)30kVA, (1)45kVA and other motor loads. Total area under the scope:  #1550= 6670 sq.ft,  #S2455= 972 sq.ft>>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
32971	14041-20000-05638	12810 N MEADOWLARK AVE	91344	12	222B133   451	2602009003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			Reviewed by Supervisor	03/18/2014 12:00:00 AM	ADDRESS	34.30331	-118.50857	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.0KWAC. 3 STRINGS 1 INVERTER WITH STRING COMBINER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32972	15041-20001-20078	10407 N JELLICO AVE	91344	12	204B129    27	2733012055	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.25969	-118.51894	Supplemental application for expedite fees only.  Addition of inverter and modules to existing solar PV array.  Total system size = 6.8 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32973	13041-10000-29391	1208 N GAFFEY ST	90731	15	021B197   197	7412023029	M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	33.75532	-118.29204	Remove HID light fixtures and replace with new fluorescent fixtures in auto shop.  Title 24 plan check only. 2856 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32974	15041-10000-28739	7335 N VAN NUYS BLVD # 208-209	91405	6	186B149   645	2218017026	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.20401	-118.44899	T24, PC FOR ENERGY ONLY, TO AN (E) COMMERCIAL BUILDING. CHANGE OF USE FROM AN OFFICE TO A MASSAGE PARLOR. B OCCUPANCY NON MEDICAL. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32975	16041-20002-42851	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM			PC Approved	06/28/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	"06-28-2019 Changes to an approved set of plan, changes include remove loads on panel ""HP"" and ""LP"". Remove panel ""LP1"". Change scope of work for Transformer ""T-EV"" and panel ""EV"" to Future scope. All changes has been clouded as delta 7. Plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32976	16041-10000-33842	11698 W SAN VICENTE BLVD	90049	11	129B145    43	4265006072	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/23/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.05347	-118.46509	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COFFE SHOP. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1100 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32977	10041-20000-25509	1999 S AVENUE OF THE STARS SUITE 2850	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	02/18/2011 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	ADDRESS	34.05886	-118.41642	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32978	19041-10000-45885	19700 S VERMONT AVE 104	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	33.85221	-118.2903	PLAN CHECK FOR TITLE 24. TOTAL AFFECTIVE AREA IS 4102 SQ/FT.permit fees done under 19041-10000-45909. only one ckt is charged under the current permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32979	14041-10001-33759	12508 W OSPREY LANE 1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	33.97856	-118.41138	Modifications to approved set.  Minor revisions related to relocation of few devices, some omissions, etc. made per inspection comments.  (((Install (N) fire alarm system with (50) notification and initiating devices for multifamily dwelling.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32980	14041-20000-26750	21300 W VICTORY BLVD floors 10-12	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.18813	-118.59618	"Plan check for power and energy. TI to existing 12-story high rise office building, floors 10, 11, and 12. 22,000sqft per floor for a total of 66,000sqft. Demoing entire floors, all circuits are new except for circuits prefaced with ""Z"" or ""VAV"". Wrong Title-24 allowance forms are on plan, applicant hand wrote and stapled correct forms to plan while on counter."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32981	12041-10001-22998	620 N STONE CANYON ROAD	90077	5	141B153   127	4362014017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2013 12:00:00 AM			Reviewed by Supervisor	01/30/2013 12:00:00 AM	ADDRESS	34.08362	-118.44384	SUPPL. APPLICATION FOR CHANGE OF DESIGN OF A NEW HYBRID 34.5KW PV SYSTEM ON A SFD. (ORIGINAL PLANS CHECKED BY BEHROOZ)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32982	18041-10000-44457	1951 S VERMONT AVE	90007	1	126B197   865	5075038001	M1-2	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.03887	-118.2918	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32983	18041-10000-40951	1510 N BENTON WAY	90026	13	142-5A207 171	5424006049	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.08531	-118.26715	4.32 KW ROOFTOP SOLAR SYSTEM, (12) AC MODULES, (1) 30A AC DISCONNECT (1) SUNPOWER MONITORING	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32984	17041-10001-00822	8020 S DUNFIELD AVE	90045	11	099B165   424	4109008028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2017 12:00:00 AM			PC Approved	02/15/2017 12:00:00 AM	ADDRESS	33.96837	-118.39966	Changes to an approved set of plans(PV1 2.4KWdc / 3.0KWac). Changes include relocating inverter, AC disconnect, and sub-panel on the roof-layout. Note: permit is paid under PCIS#17041-10000-00822	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32985	12041-20000-21879	9340 N OWENSMOUTH AVE	91311	12	198B105    77	2746014043	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Approved	09/26/2012 12:00:00 AM	ADDRESS	34.24067	-118.60169	Plan check for energy and emergency lighting. Clean room. Building is equipped with inverter battery backup.4395 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32986	16041-20000-02121	3770 S BUCKINGHAM ROAD	90008	10	117B181   283	5045007028	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Expired	02/19/2018 12:00:00 AM	PIN	34.01780054	-118.33996057	PV1. Install roof mounted PV system sized 850W. Interconnected with main service panel. (4) Solarworld SW-250 Modules(4) Enphase M215 Microinverters	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32987	11041-10000-13666	351 E SUNSET AVE 1-6	90291	11	109-5A143 577	4286006036	[T][Q]CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	33.9959	-118.474	NEW 3-STORY APARTMENT CONSTRUCTION, WITH NEW SERVICE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32988	15041-10000-21797	3900 N STANSBURY AVE	91423	4	162B153  1094	2274027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.14084	-118.44264	(N) 88-device fire alarm system for (N) 1-story school building over one basement level.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32989	11041-10001-07318	310 S ROBERTSON BLVD	90048	5	138B169   610	4334011034	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.07318	-118.38361	MODIFICATION OF APPROVED LIGHTING TO PCIS # 11041-10000-07318.  TITLE 24 PLAN CHECK ONLY. <<<<<<<RESTAURANT REMODEL.  (REF. W/ PLAN CHECK #10041-10000-21916)>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32990	14041-10000-00299	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	THIS IS A TWO STORY BLDG, RETAIL,  TITLE 24 AND EMERGENCY LIGHTING. TAILORED METHOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32991	10041-10001-03267	6906 W HOLLYWOOD BLVD 2nd Floor	90028	13	147B181   194	5548006008	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM			Reviewed by Supervisor	04/16/2010 12:00:00 AM	ADDRESS	34.10137	-118.34052	Plan check for power only. First time tenant. T-24 Energy was approved under application #10041-10000-0326.  Permit under #10041-10000-03280	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32992	15041-20000-36622	23706 W VICTORY BLVD	91367	3	180B093   851	2033018019	C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.18645	-118.64336	Proposed  984 SF retail & 2,516 SF  convenience store.  Full PC Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32993	15041-10000-02468	1712 W SUNSET BLVD	90026	13	139-5A209 143	5404017020	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.07724	-118.25897	ALTERATIONS IN RETAIL STORE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32994	15041-20000-29070	17349 W HARTLAND ST	91406	6	183B133   830	2229007043	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.19518	-118.51153	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel.(23) Kyocera KU 265 Moudles(1) PVI-5000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
32995	13041-20001-32360	2622 S LA CIENEGA BLVD PV2	90034	10	123B173  1992	5065012046	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	ADDRESS	34.03458	-118.37741	EXPEDITE FEES ONLY<<<New 12.09kw rooftop commercial PV System for an existing commercial building.  System is negatively grounded.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32996	17041-20000-14962	110 E 9TH ST 12TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Closed	02/09/2024 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLAN CHECK FOR POWER AND ENERGY 2016. TENANT IMPROVEMENT FOR OFFICES (IGNIGHTED SPACES) ON 12TH FLOOR EXISTING HIGH RISE. RELOCATE EXISTING TRANSFORMERS AND PANELS.  PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-20000-20001.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
32997	14041-20000-21157	20311 W HOWARD CT	91364	3	165B113   167	2174008022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.14734	-118.57619	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 12kW(1) SolarEdge SE11400A-US transformerless inverter(40) SunPower X21-345 pv modules(40) SolarEdge P400 power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
32998	12041-10000-21410	10900 W WILSHIRE BLVD #100	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.05848	-118.44419	TENANT IMPROVEMENT: change an existing bank to a new citi bank; customer requested full plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
32999	15041-20000-14299	1505 N EDGECLIFFE DR	90026	13	144A203    12	5429021027	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.09089	-118.27763	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,010 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33000	14041-10002-10508	624 W ISABEL ST	90065	1	144A221    75	5453018014	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1853.10	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	34.09042	-118.22052	PV1 CHANGES TO APPROVED: MODULE WATTAGE UP FROM 250 TO 265. PV1 3.71KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(14)modules: {Suniva Optimus OPT265-60-4-1B0}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33001	17041-10000-46578	11601 W WILSHIRE BLVD 19TH FL.	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR TENANT IMPROMENT TO THE (E)COMMON AREAS ON HIGH RISE BUILDING (19TH) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES IN CORRIDOR RESTROOM AND ELEVERTOR LOBBY.  TOTAL AFFECTED AREA 1654 SQ.FT.B# 17016-20000-34042	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33002	19041-20000-40762	15012 W MARTHA ST	91411	4	174B145   413	2243009014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.1729	-118.45996	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM AND 13.5 KWH ENERGY STORAGE SYSTEM. PV SYSTEM SIZE IS 8.19 KW DC/7.6 KW AC. SCOPE OF WORK CONSISTS OF (26) PV MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER, A 200A LOAD CENTER,  AND A 13.5 KWH BATTERY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33003	10041-10000-18722	2049 S CENTURY PARK EAST # 23RD FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	TENANT  IMPROVEMENT IN OFFICE AND STORAGE AREAS IN SUITE # 2300PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33004	15041-10000-31034	2028 E 7TH ST	90021	14	124-5A217 262	5166015002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.03441	-118.23125	Install new emergency lighting, panels and service are all existing. Low rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33005	13041-10000-08265	1330 E FACTORY PL B-J	90013	14	126A215   231	5164008032	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			04/01/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Issued	04/01/2013 12:00:00 AM	ADDRESS	34.03898	-118.23515	ADDITION OF DISTRIBUTION SECTION FOR PREVIUOSLY APPROVED PLAN. NEW 800A SECTION TO SUBFEED 4 NEW PANEL BOARDS FOR FUTURE TENANT SPACE. PC FOR POWER AND ENERGY. ENERGY FOR TEMPORARY LIGHTING IN FUTURE TENANT LEASE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33006	18041-10000-14668	13750 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.30953	-118.43339	PC FOR BANK TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA  7400  SQ.FT REPLACING EXISTING LIGHTS WITH UL LISTED RETROFIT LED KIT. EXISTING EMERGENCY LIGHTS AND SWITCHING TO REMAIN.INDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33007	19041-10000-04390	3790 W WILSHIRE BLVD	90010	10	132B193    69	5093006030	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.06153	-118.30861	PLAN CHECK FOR TITLE 24, ENERGY ONLY. LIGHTING AND POWER RENOVATION FOR (3) BAR AREAS OF EXISTING HISTORICAL BUILDING. TOTAL SQUARE FOOTAGE = 7362 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33008	19041-10000-52576	3860 S VICTORIA AVE	90008	10	117B185   855	5045019024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Issued	12/19/2019 12:00:00 AM	ADDRESS	34.0156	-118.3366	NEW PV1 ROOF-MOUNTED INSTALLATION TO A SERVICE OF 200 AMPS. INSTALLATION INCLUDES 2 ENERGY STORAGE SYSTEM, 26 MODULES (Q.PEAK DUO BLK-G5 315), 26 OPTIMIZERS (P400), 1 CENTRAL INVERTER (SE7600H), 1 PANEL OF 125 AMPS, AND 1 PANEL OF 200 AMPS.   SYSTEM SIZE: 8.19 KW DC; 7.6 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33009	15041-10000-38106	630 W 6TH ST #110B	90017	14	129A209   260	5144005***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.04916	-118.25624	T-24, TI IN AN (E) RESTAURANT, SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTACLES IN IN THE KITCHEN SPACE. PC FOR ENERGY ONLY, TOTAL SQ. FT. 225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33010	14041-10000-28828	1157 N GALLOWAY ST	90272	11	129B129   270	4423004022	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.05075	-118.522	PV1, INSTALL 3.85 KW DC ROOF-MOUNTED SOLAR ARRAY ON HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH BATTERY BACK UP.(14) MODULES: SOLARWORLD SW275(1) INVERTER: SCHNIDER E;ECTRICAL MPPT 80 600	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33011	17041-20000-04897	307 S BROADWAY	90013	14	130-5A211  77	5149015026	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.05086	-118.24845	Plan check for energy only. Install new facade lighting on exterior of existing building. 7,278sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33012	16041-20000-03744	16900 W CHATSWORTH ST	91344	12	207B133   523	2684001036	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.2646	-118.50007	Plan check for Out door lighting in front yard. Total area: 3300 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33013	16041-10000-44613	10250 W SANTA MONICA BLVD # 1910	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Kate Spade"" Ste. 1910.  Install new Xrfmr, and  panels, total area 1200 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33014	19041-10000-48921	2670 N GRIFFIN AVE	90031	1	139-5A223 398	5206010040	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.07841	-118.21167	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33015	19041-10000-51171	11840 N GLENCREST DR	91340	7	216B157    46	2524001052	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	04/23/2021 12:00:00 AM		Permit Finaled	04/01/2022 12:00:00 AM	ADDRESS	34.28557	-118.4227	FULL PLAN CHECK FOR A CHANGE OF USE TO VOCATIONAL SCHOOL, TOTAL NEW LOAD EXCEED 400A. AREA OF SCOPE (32,833)SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33016	13041-10000-32329	4443 N AUCKLAND AVE	91602	4	165B177   174	2424002032	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.15158	-118.36062	PV1, Install 2.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33017	12041-10000-06996	3550 S TROUSDALE PKWY	90089	8	118-5A201   9	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.02094	-118.28463	PLAN CHECK FOR USC LIBRARY INFRACTURE UPGRADE. EXISTING SERVICE AND MOTOR EQUIPMENT. NEW SWITCHBOARDS, PANELS, ATS, AND GENERATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33018	14041-20001-35051	3433 E ALICE ST	90065	1	147A219   237	5454027002	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	01/20/2015 12:00:00 AM	ADDRESS	34.09659	-118.2259	EXPEDITED PER CUSTOMER REQUEST.PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZE 7.6 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(22) SUNPOWER E20/327MODULES(2) POWER ONE PVI3.8 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33019	13041-10001-30425	5801 N COSTELLO AVE	91401	2	174B153   279	2246015013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.17597	-118.43788	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33020	15041-10000-02970	1204 W G ST	90744	15	030B201   410	7416009002	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	33.7776	-118.27691	PV1 STANDARD PLAN RESIDENTIAL. 10 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33021	19041-20000-09133	12571 W TIBBETTS ST pv1	91342	7	228B161   742	2580005010	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.31882	-118.40728	pv1install roof mounted pv system sized 5KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33022	15041-10000-29911	9767 N GLENOAKS BLVD # B	91352	12	201B169    89	2537022012	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.24699	-118.38486	PC for energy only.  Remove HID light fixtures and replace with new LED fixtures.Total area: 1796  sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33023	15041-10000-33966	5337 E RAPHAEL ST	90042	1	153A227   115	5469026016	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.11445	-118.20068	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.STANDARD PLAN CENTRAL STRING INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33024	16041-20000-21441	12234 N WINDMERE DR	91342	7	219B149   890	2507009***	(Q)RD3-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.29419	-118.4496	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.  STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33025	16041-20000-01219	5471 N BOTHWELL ROAD	91356	3	174B117   512	2164009006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.1704	-118.5613	PV1. Install roof mounted PV system sized 3.6 kW. Interconnected with main service panel. (18) Kyocera KU2656 Modules(1) ABB PVI 3.6 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33026	17041-30000-41657	8511 N FALLBROOK AVE 2nd Floor	91304	12	192B097   585	2005022004	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.22466	-118.62773	Plan check for Title 24 only in existing 3 story building office T.I.. Total area: 21,415 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33027	15041-10001-16209	555 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM			PC Info Complete	06/23/2015 12:00:00 AM	ADDRESS	34.13776	-118.3584	CHANGES TO AN APPROVED SET, NOTE CHANGES IN DELTA 1. ADDED CORRIDOR TO SCOPE OF WORK. T-24((TI-24 TO AN (E) COMMERCIAL BUILIDNG. EXISTING PANELS NEW LED LIGHTING. TOTAL SQ. FT. 1095))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33028	12041-10000-03300	724 N GRAMERCY PL	90038	13	141B193   480	5535015010	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			02/13/2012 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.08427	-118.31231	Plan check new fire alarm system existing 20 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33029	17041-20000-37285	5406 N CREBS AVE	91356	3	174B121   721	2161006021	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.16921	-118.54355	addition of (2) tesla powerwall.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33030	13041-10001-17733	14682 W TYLER ST	91342	7	225B149   429	2505024032	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.31038	-118.45288	CHANGES MADE TO AN APPROVED SET; MODULES CHANGED FROM 250W TO 255W, DC SYSTEM SIZED AT 6.63KW DC. FEES CHARGED PER APPLICANT REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33031	17041-10000-02438	4241 W NEWDALE DR	90027	4	150B201   834	5591013040	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.10611	-118.28226	PC FOR ROOF MOUNTED  PV SYSTEM USING 12 MODULES TYPE AC - TOTAL SIZE 4.32KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33032	17041-10000-10204	433 S CURSON AVE EAST GARAGE # 3	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.06735	-118.35387	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 22000 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33033	13041-10001-03946	1201 S LA BREA AVE	90019	10	129B181    91	5084028060	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	ADDRESS	34.05316	-118.34389	REVISION TO APPROVED PLANS. ADDITIONAL LIGHT FIXTURES ADDED TO INDOOR AND OUTDOOR LIGHTING. PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING RETAIL TENANT INPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33034	12041-10001-19239	652 S HILGARD AVE	90024	5	135B153   142	4360015029	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	34.06799	-118.43898	PLAN CHECK FOR NEW FIRE SYSTEM UP-GRADE AT THREE UCLA SORORITY HOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33035	19041-20002-19948	9121 W LA TUNA CANYON ROAD	91352	7	198B185    42	2545024022	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.23661	-118.3316	Revisions to approved set of plans.  Distribution detail and interconnection changes.  Approval for entire plan - no identified revisions.(((PV1.  Install 21.00 kW DC / 18.85 kW AC roof mounted grid tied PV system.  (56) modules with microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33036	12041-10000-24581	12886 W KAMLOOPS ST	91331	7	204B161   559	2623026021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM			Reviewed by Supervisor	10/25/2012 12:00:00 AM	ADDRESS	34.25395	-118.4132	PV1 - PLAN CHECK 1.92KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING AURORA TRANSFORMERLESS INVERTER - ONE STRING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33037	13041-20000-06235	6200 N CANOGA AVE STE 400-STE 425	91367	3	177B105   127	2149001035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.1833	-118.59719	Plan check for energy and emergency lighting. Input 1. Suites 400 & 425. Commercial low-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33038	10041-10000-10581	1109 E VERNON AVE	90011	9	112-5A209  57	5115034003	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM	09/03/2010 12:00:00 AM		Permit Finaled	10/27/2010 12:00:00 AM	ADDRESS	34.00405	-118.25595	New office building for Family health center. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33039	19041-10000-06780	6263 N TOPANGA CANYON BLVD	91367	3	177B101    20	2146001025	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	10/18/2021 12:00:00 AM	ADDRESS	34.18482	-118.60621	PLAN CHECK FOR A NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. SCOPE INCLUDES 1 PANEL AND 1354 DEVICES. 7 STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33040	17041-20002-42400	4357 E SAN RAFAEL AVE	90065	1	153A223   350	5471009008	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.11212	-118.21293	01/24/2018 Changes to an approved set of plans. All changes have been clouded. Electrical equipment has been relocated into the garage.*****Previous Work Description*****PV1.  Install 11.05 kW roof mounted grid tied PV system.  (34) modules with (2) 5.2 kW rated string inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33041	15041-20000-28592	8445 N JAMIESON AVE	91325	12	192B129   170	2787011020	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.22393	-118.52177	PV1. Install roof mounted PV system sized 8.8 kW. Interconnected with main service panel.(27) SPR 327NE Modules(1) SMA SUNNYBOY SB3800 TL(1) SMA SUNNYBOY SB5000 TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33042	15041-10000-41324	13400 W CORNELIUS ST	91331	7	213B157   536	2523014014	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.27907	-118.42444	PV1 SFD TOTAL SYSTEM SIZE 3.8KW AC USING CENTRAL INVERTER SYSTEM WITH 20 MODULES TOTAL. SYSTEM USES POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33043	16041-10000-41307	2205 S STONER AVE	90064	11	123B149   476	4260011002	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.03331	-118.44863	TI TO OFFICE SPACE. NEW LIGHTING, POWER AND SERVICE UPGRADE. NEW 600A 120/240 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD. NEW TRANSFORMER AND 3 PANELS.  PC FOR POWER AND ENERGY. TOTAL AFFECTED AREA IS 8000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33044	13041-10001-16324	11929 W COURTLEIGH DR	90066	11	111B157  1103	4233018006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			06/03/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	33.99687	-118.41943	revisions to permitted set of plans:residential distribution board is rated 1phase 3W INSTEAD OF 3PH 4W;SUMP PUMPS AND BOILER EQUIPMENT ARE REMOVED AND EV CHARGERS UPSIZED; ALL CHANGES ARE CLOUDED; SERVICE LOAD CALCULATIONS WERE REVISED ACCORDINGLY(((((((((New 4-story 22-unit apartment building.  Power and energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33045	14041-10000-30829	12111 W BRANFORD ST	91331	7	204B165   205	2537017***	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	PIN	34.25399397	-118.39802265	Energy plan check for a warehouse by replacing HID fixture to LED lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33046	14041-20000-30135	142 S HAYWORTH AVE	90048	5	138B177  1164	5511026010	R3-1	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.07287	-118.36241	PLANCHECK FOR POWER AND ENERGY . New 6-unit small lot subdivisions. Each subdivided lot has a new 4-story SFD W/ ATT GARAGE. All SFDs served from a single 800A service. Project located in Methane Zone. Variance filed to use multi-family dwelling demand calculation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33047	12041-20002-23783	20332 W VIA SANSOVINO PV-1	91326	12	219B113   280	2701061020	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.29651	-118.57665	Changes to approved set of plans due to DWP requirements. Changes to 1-line diagram (only one AC disconnect per DWP). 12041-20001-23783 was created in error.Single famil dwelling PV solar installation. 2 tranformerless inverters (Power-One). System size is 11.025 kW DC, 9.41 kW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33048	11041-20000-09222	12940 W RAYMER ST	91605	2	186B161   523	2327016028	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Info Complete	05/06/2011 12:00:00 AM	ADDRESS	34.20474	-118.41506	T.I. to existing building.  Install general/emergency lighting for outdoor and indoor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33049	17041-20003-01429	8915 N WOODLEY AVE	91343	12	195B141   264	2688004017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.2325	-118.48529	[[[3/20/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES. ADDING PERFORMANCE METER TO THE SINGLE LINE]]]][[[3/9/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES HAVE BEEN CLOUDED WITH DELTA 1. CHANGES TO THE MODULE LAY OUT. DERATING MAIN BREAKER TO 175 AMPS ]]]]]pv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33050	15041-10000-19742	11022 W CAMARILLO ST	91602	4	168B173  1169	2353026078	R3-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	Apartment			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.15745	-118.37141	NEW FIRE ALARM SYSTEMS FOR 15 UNIT APARTMENT BUILDING. 71 DEVICES AND 1 FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33051	16041-10000-39671	14500 W OLIVE VIEW DR 1-100	91342	7	228B149    20	2502024024	QRD1.5-1, RD1.5-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	Apartment			11/08/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.32399	-118.44867	PV, INSTALLATION OF 13.26 KW DC/12 KW AC ROOF-MOUNTED ON A PARTMENT BUILDING.(52) MODULES: CS6P255P-1-SMA(2) INVERTERS: SB7000US-12& 5000US-12	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33052	18041-10000-19251	12105 N ARROYO VISTA WAY	91326	12	219B109    13	2701001047	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.29288	-118.58648	FULL PLAN CHECK FOR A NEW RECREATIONAL BUILDING/POOL EQUIPMENT ROOM(BUILDING 1 OF 2) WITH ATTACHED TRELLIS. SCOPE INCLUDES A NEW 400 A, 120/240V SERVICE, (5) NEW SUBPANELS, AND CIRCUITS. TOTAL AFFECTED AREA IS 21,338 SQ. FT. B# 16010-20000-05708NOTE: OTHER STRUCTURE IS SUBMITTED UNDER APPLICATION PCIS#18041-10000-34040	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33053	10041-10000-08331	10707 W MISSOURI AVE	90025	5	129B157   484	4321004029		West Los Angeles				2671.00	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	05/05/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.05074	-118.43148	NEW FIRE LIFE SAFETY SYSTEM IN THE APT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33054	19041-20000-15898	2347 S SELBY AVE	90064	5	126B157   547	4320004103	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.04274	-118.42685	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SINGLE FAMILY DWELLING. SYSTEM SIZE IS 11.52KW DC/10.43KW AC CEC/10.08KW AC. SCOPE OF WORK INCLUDES (32) SUNPOWER PV MODULES WITH ENPHASE IQ 7 MICROINVERTERS, AND A 100A PV LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33055	15041-10000-26869	200 WORLD WAY TERM 2-DEPT LEV 3	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	"TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 DEPT  LEV 3  SPACE 223PLAN CHK IS FOR TITLE 24 by adding fixture  "" E "" in addition to the newly approved permit."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33056	18041-10000-30292	10960 W WILSHIRE BLVD 22ND FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.058	-118.44597	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE "" PLAYBOY ENTERPRISE"" (3,900 SQ.FT.). 22ND FLOOR.BUILDING PERMIT # 18016-10000-24889"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33057	17041-10000-42401	4501 N BERENICE AVE	90031	1	145-5A225 214	5303005018	[Q]R1-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Expired	09/14/2023 12:00:00 AM	ADDRESS	34.09332	-118.20198	PC for Tesla powerwall (5kW) with new 125A load center in SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33058	13041-20000-34773	9301 N TAMPA AVE #142	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	New restaurant in an existing space.  Place of Assembly, FULL Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33059	12041-20000-10624	4274 S MAIN ST	90011	9	114A205   310	5113031031	C2-1VL	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	PIN	34.00583482	-118.27362194	Lighting changes to existing Coing laundry ( 11041-10000-14790 )Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33060	18041-10000-46064	333 S GRAND AVE STE 1711	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLAN CHECK FOR T24 ONLY, INTERIOR OFFICE TI TO CREATE EMPLOYEE BREAKROOM/CATERING AREA  (PORTION OF 17TH FLOOR), NEW CONNECTED POWER < 200A , AND ARE FED FROM EXISTING PANEL BOARDS. TOTAL AREA: 4402 SQ.FT   (B# 18016-10000-36130)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33061	17041-10001-29089	345 N WESTMORELAND AVE	90004	13	138B197    81	5501002033	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Apartment			09/05/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.07753	-118.28811	Change to approved set by updating the fault current calculation. All changes under delta-3 only.(((PLAN CHECK FOR ROOFTOP SOLAR SYSTEM - SYSTEM SIZE(18KWac) CONSISTING OF 2 CENTRAL INVERTERS(SOLAREDGE SE9KUS) AND 61 MODULES(HYUNDAI-S350TI) WITH 32 POWER OPTIMIZERS(P700) )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33062	19041-20000-16553	23224 S LOCKNESS AVE	90710	15	042B193    36	7438003024	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	33.81466	-118.30471	Plan check for PV roof mounted system, system size: 10.56KW DC, 9.725KW AC with 32 PV Modules and 32 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33063	18041-10000-17999	811 W WILSHIRE BLVD 4TH FLR.	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.04973	-118.2584	PC FOR OFFICE INTERIOR TI IN A HIGH RISE BUILDING. SCOPE INCLUDES NEW PANELS, EQUIPMENT,  LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 12512 SQ.FT. B#18016-10000-13805	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33064	17041-10000-09503	9525 N COZYCROFT AVE	91311	12	201B109   346	2748040005	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.24347	-118.58211	PC for energy only, outdoor only. Removing HID fixtures and replacing them with new LED ones. Area: 15,600..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33065	13041-10001-30838	3609 S ROXBURY ST	90731	15	006B197   419	7469019025	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	33.71302	-118.29753	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 3.75 KW.(15) TRINA SOLAR # TSM-250PA05.18(15) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33066	17041-20000-25480	9201 N OAKDALE AVE Ste 200	91311	12	198B113   214	2761001084	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.2381	-118.56706	Three new offices in (E) commercial office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33067	14041-20000-25055	5469 N OAKDALE AVE	91364	3	174B113   509	2164003001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Expired	10/20/2016 12:00:00 AM	ADDRESS	34.17012	-118.56599	FEE CHARGE IS $0.00 BY STATE SENATE BILL NO. 1222PV1.  Install 15.04 kW roof-mounted, utility-interactive PV system.  SolarEdge inverters SE5000 and SE6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33068	17041-10000-39807	11820 W OLYMPIC BLVD	90064	11	123B149   524	4259024005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.03285	-118.4503	Remove indoor/outdoor HID Fixtures and replace it with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33069	16041-10000-29831	1925 S CENTURY PARK EAST # 2100	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE AT SUITE 2100.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3729 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33070	13041-20000-10359	18800 W TRIBUNE ST	91326	12	207B121   148	2717023027	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2013 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.26668	-118.54319	New 9.36kw rooftop mounted PV System for an existing single family residence. SUBMITTAL 2 FEE PERIOD TO EXPEDITE ASSIGNMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33071	14041-10001-26862	412 N FAIRFAX AVE	90036	5	141B177  1435	5527030018	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	34.07866	-118.36128	Change to approved set by changing lighting ficture 'A'. All changes  are under delta-5 only.(((PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT, NO CHANGE IN OCCUPANCY. MR. PIZZA. 1240 SQFT, EMERGENCY LIGHTING.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33072	11041-10000-26925	10201 W PICO BLVD bldg 99-4th flr	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM			PC Approved	12/16/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	T.I. to a low-rise office building.  Bldg 99, 4th floor.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33073	12041-10000-11757	190 S GRANVILLE AVE	90049	11	132B145    50	4401002001	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.06119	-118.47046	New 11kW, rooftop, PV system for single family dwelling.   Plan check is only for the PV System.    Contractor is reducing main breaker on 1st bus of split bus panel - Inspector to verify that new 175A  breaker is not Undersized.  Permit Fees are under Inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33074	13041-10000-05763	1055 W 7TH ST SUITE-3100	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.0507	-118.26334	PLAN CHECK FOR TITLE 24 FOR TENANT IMPROVEMENT ON A HIGH RISE BUILDING PHASE II. 4665 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33075	10041-20000-12061	10919 N SEPULVEDA BLVD	91345	7	210B145   411	2664012024	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1093.00	Electrical	Electrical	Public Safety Only			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Expired	10/19/2012 12:00:00 AM	ADDRESS	34.26825	-118.46736	Plan check for installation of new sprinkler monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33076	16041-20000-41339	5410 W WILSHIRE BLVD Ste 200	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.06204	-118.34668	Partial 2nd floor TI in (E) commercial highrise building.  Plan check for energy.  No generator on site - unit equipment is allowed per filed modification contingent on no change of use or occupancy per Dave Maclean.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33077	11041-10002-16499	3571 W WILSHIRE BLVD	90010	10	132B193    19	5503025013	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM			PC Approved	04/13/2012 12:00:00 AM	ADDRESS	34.06192	-118.3025	Revisions as of 04/13/2012, plan check for luminaire changes on types A, G1, and K.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33078	10041-10000-04759	8706 W 3RD ST	90048	5	138B169   562	4334011008	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	03/17/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.0734	-118.38211	TI IN AN EXISTING RESTAURANT. PLAN CHECK IS FOR TITLE-24 ENERGY CALCS AND EMERGENCT LIGHTS. PERMIT IS FOR REPLACING EXISTING LIGHTS & SWITCHES. EXISTING PANELS & CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33079	12041-10002-29875	10500 W KLING ST	91602	4	168B177   734	2420032006	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	04/24/2013 12:00:00 AM	ADDRESS	34.15572	-118.35931	PV1.  New 14.388 KW roof mounted PV system for a single family residence.  Installing 44 modules, 2 ombiner boxes, 2 inverters, and 1 sub panel.((((((  one j box changed , the dim 4*4*4 and the other one is 4*36*6 , addition of new ground rod to the inverter. 5/8 * 10 . and 1'' conduit from bldg to garage , run on wooden fence, OK by Mr. ferguson.))))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33080	13041-10000-07043	6001 W FOREST LAWN DR	90068	4	168B189   276	5581001906	OS-1XL-H	Central	Hollywood	Greater Griffith Park, Hollywood Hills West	YES	1882.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Closed	04/24/2013 12:00:00 AM	ADDRESS	34.15285	-118.32012	RENOVATION OF ELECTRICAL SYSTEM FOR RESERVOIR IN FOREST LAWN. NEW PANELS AND TRANSFORMER USED FOR TEMPORARY POWER. CIRCUITS WILL BE LEFT TO ANOTHER CONTRACTOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33081	16041-10000-43931	888 S FIGUEROA ST STE 630	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI TO OFFICE SPACE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33082	18041-20000-00879	15013 W SUNBURST ST	91343	6	195B145    43	2651018002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.23459	-118.45923	pv1install roof mounted pv sysetm sized 6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33083	18041-10000-11527	1501 N MAIN ST	90012	1	136-5A217 147	5409003042	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	PIN	34.06690042	-118.22937525	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33084	17041-10000-25633	360 E 2ND ST 2ND FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM			PC Info Complete	07/27/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	TITLE 24 PLAN CHECK FOR TI (COMPLETING SPEC SUITE 275 AND LOUNGE SPACE ON A MULTI TENANT FLOOR.) TOTAL AFFECTED AREA = 3419 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33085	10041-10000-08973	6600 N TOPANGA CANYON BLVD # 2069	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM	06/18/2010 12:00:00 AM		Permit Finaled	07/20/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI-REMODEL RETAIL SPACE (849 SF).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33086	18041-20000-44745	2759 N CASIANO ROAD	90077	5	156B145   224	4378031030	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.12321	-118.47144	PV1.  Install 13.53 kW DC roof mounted grid tied PV system.  (41) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33087	16041-10001-35357	11916 W PICO BLVD	90064	11	123B149   970	4259039009	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.02999	-118.44856	"DELTA ""9"" CHANGES TO APPROVED PLANS FOR CHANGING FEEDERS ON PAGE E-14. <<<Plan check for power and energy. Project site is a new 5-story, 100-unit mixed use apartment and retail building over 2 levels of basement parking garage. Total lighting area = 78,288 sq. ft.Note: Building application has been created under 16010-10000-01632>>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33088	15041-20000-10131	11054 W CASHMERE ST	90049	5	138B149   250	4366025005	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.07115	-118.45613	Plan check for PV1 roof mounted 13kW system with 44 modules(SUNPOWER SPR0327-NE-WHT-D) and 2 inverter(SAM AMERICA-SB8000US, -SB5000TL0US-22)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33089	17041-20000-01429	8915 N WOODLEY AVE	91343	12	195B141   264	2688004017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.2325	-118.48529	pv1install roof mounted pv system sized 10kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33090	14041-10001-01572	1724 W 254TH ST	90717	15	036B193   928	7410013059	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	33.79339	-118.30869	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 5.25 kW DC roof-mounted solar array for a two story house, interconnect with exsisting service panel. (1) Transformerless inverter(s):n Solaredge SE5000A-US. (21) Modules: TRINA SOLAR TSM-250PA05.18.(21) Optimizer:SOLAREDGE  OP250-LV-AH4SM-2NA-Z.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33091	14041-20000-23783	8437 N WHEATLAND AVE	91352	6	192B177   311	2404022006	R1-1	North Valley	Sun Valley	Sun Valley Area		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	PIN	34.22411901	-118.36205706	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNECTED WITH MSP.(16) SUNEDISON F270KYC MODULES(16) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33092	11041-20000-20483	14800 W VENTURA BLVD Phase-3B	91403	5	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			09/26/2011 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.15186	-118.45547	PHASE 3Bcomplete plan checkRequest for Modification to separate Fire Alarm system filed .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33093	15041-20000-02106	13003 W GARBER ST	91331	7	204B161    45	2623001024	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.25895	-118.41587	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.(32) SUNPOWER 327W MODULES(2) POWER ONE PVI-5000 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33094	17041-20000-31993	19549 W TULSA ST	91326	12	210B117   270	2708007020	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.26892	-118.55928	Plan check for a PV1 roof-mounted PV system. System size is 7.8 kWac and consists of (34) micro-inverters, (34) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33095	13041-10004-05741	380 WORLD WAY space T71	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	CHANGES MADE TO APPROVED SET.  ADDING BRANCH CIRCUITS, RELABELING EXISTING BRANCH CIRCUITS, UPSIZING BREAKERS FOR PCU1, AND ADDING 2 EXAUST FANS IN THE KITCHEN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33096	14041-20000-18216	5347 N HINTON AVE	91367	3	171B093   123	2044012005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.16786	-118.63771	FEE CHARGE $0.00 BY STATE SANATE BILL NO. 122212KW PV1 roof-mounted system with (48) Enphase M215 microinverters and Trina Solar TSM250P modules .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33097	18041-10000-10289	404 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.04451	-118.25625	FIRST TENANT -PARIS BAGUETTE- IN RETAIL SPACE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33098	15041-10000-07676	1326 S CENTINELA AVE 1-10	90025	11	126B145  1242	4267034127	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			03/16/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.03942	-118.46844	Full plan check for a new 10-unit 4-story apartment building. Scope including (1) 1000-Amps service, (2) switchboard, 12-panel and a total T24 area is 13177-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33099	18041-10000-17405	21404 W SHERMAN WAY	91303	3	183B105   205	2111028008	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.20085	-118.59794	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33100	15041-20000-28076	10100 W SANTA MONICA BLVD 7th Floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Approved	08/26/2015 12:00:00 AM	ADDRESS	34.06191	-118.41691	Title 24 plan check only.  Total area = 1,392 sq. ft.  T.I. to individual office spaces in existing commercial highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33101	18041-20000-34296	729 S MAIN ST	90014	14	127-5A211 333	5144015054	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.04351	-118.25239	Plan check for power and energy for service upgrade  to 1600 A  back feed to existing 800A distribution and add new circuits in each unit for 98 units Hotel 4 story building. Total area: 10737 sq ft. B#18016-10000-09826	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33102	15041-10000-11939	9708 W APPALOOSA WAY	91040	7	204B181    87	2549025051	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Expired	05/16/2017 12:00:00 AM	ADDRESS	34.25862	-118.34248	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33103	15041-20001-27751	700 W 9TH ST	90015	14	129A207   333	5138017***	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.04579	-118.2618	08/29/2016 - Changes to an approved set of plans. All changes have been clouded and marked as Delta C.*****Previous Work Description*****Plan check power and energy for new High-rise 31-story with 281 units. Total inddor area: 31,520 sqft.  Note: Applicant has pre-cut check; plan check engineer shall verify the number of circuits and panels one more timeFire alarm Variance has been filed 08-24-2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33104	19041-10000-50156	11082 N OSO AVE	91311	12	210B113    52	2707030018	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	03/04/2020 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.27177	-118.57483	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 26  (PANASONIC 325W) MODULES, 26  (SOLAREDGE P400) OPTIMIZERS, 1 (SE7600H-US) CENTRAL INVERTER, CONNECTED TO AN UPGRADED 125A MAIN SERVICE PANELL. SYSTEM SIZE IS 8.45KW DC & 7.60KW AC. MAIN PANEL UPGRADE UNDER SEPERATE PERMIT (EXPRESS).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33105	10041-20000-02467	5900 W WILSHIRE BLVD 3RD FLR	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM			Not Ready to Issue	02/16/2010 12:00:00 AM	ADDRESS	34.06237	-118.35809	Tenant improvement of existing office areas. Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33106	14041-10001-13137	1243 S WELLESLEY AVE # 6	90025	11	126B145   494	4267036012	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			Reviewed by Supervisor	05/29/2014 12:00:00 AM	ADDRESS	34.0418	-118.46837	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 12.50 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER AND TRANSFORMERLESS INVERTERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33107	17041-20000-04270	21034 W VENTURA BLVD	91364	3	171B105   274	2167024006	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.16654	-118.59193	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL SPACE. 3449 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33108	14041-20000-24842	7010 S HOOVER ST Unit #8	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #8. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33109	13041-20000-10076	6900 N LAUREL CANYON BLVD	91605	6	183B165   329	2321011019	RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.04	Electrical	Electrical	Apartment			04/23/2013 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.19603	-118.39625	New 9 unit 3 level apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33110	17041-20000-37564	407 E 120TH ST	90061	15	084B205  1139	6083029027	R3-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			10/18/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	33.92385	-118.26736	Plan check for solar pv system mounted on carport in apartment complex. System is serving apartment building 1. Total system size: 22.8kW ungrounded.(3) SolarEdge 7.6kW inverters. (108) 280W pv modules.Each module has a 300W power optimizer.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33111	11041-10000-21651	7060 W HOLLYWOOD BLVD	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	12/15/2011 12:00:00 AM	ADDRESS	34.10137	-118.34379	installation of facade lighting-LED STRIP LIGHTING-on the building housing the Buffalo Wild Wings restaurantplan chk is for Title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33112	12041-10000-14758	1055 W 7TH ST 32nd floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	34.0507	-118.26334	Plan check for energy and emergency lighting. 32nd Floor. 500 sqft. Commercial high-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33113	14041-10000-30871	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Expired	04/06/2020 12:00:00 AM	ADDRESS	34.07196	-118.24719	770' 4160 V feeder cable installation in existing conduits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33114	12041-10000-13331	4424 S WESTERN AVE	90062	8	111B193   274	5016004004	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM			PC Approved	06/08/2012 12:00:00 AM	ADDRESS	34.00302	-118.30872	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR EXISTING COIN LAUNDRY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33115	19041-10002-09386	8240 N BABCOCK AVE	91605	2	192B161   169	2308004014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.22111	-118.40698	"DELTA ""1"" CHANGES TO APPROVED PLANS. RELOCATING ELECTRICAL AND PV EQUIPMENT. <<<NEW ROOFTOP SOLAR SYSTEM CONSIST OF 23 MODULES (Q-CELL 305) , 23 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 7.015KWdc and 6KWac>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33116	14041-20001-00623	9678 N NATICK AVE	91343	7	201B149   541	2650018030	RS-1	North Valley		North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.24593	-118.45386	note: void application; expedited fee under 14041-20002-00623	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33117	14041-20000-04620	6253 N COLFAX AVE	91606	2	177B169   192	2334007027	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.18447	-118.38794	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33118	17041-10001-09736	4851 S ALAMEDA ST	90058	9	111A215    13	5106027002	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Info Complete	06/23/2017 12:00:00 AM	ADDRESS	33.99921	-118.23904	CHANGES TO APPRVOED SET OF PLANS. ADDED EXIT SIGNS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33119	11041-20001-06066	1059 S GAYLEY AVE	90024	5	132B149    84	4363025005	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.06086	-118.44724	Plan check power and energy for optopmetrist office. Permit for 200 amp service and panel was issued on previous application number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33120	17041-10000-40702	5944 N FIGUEROA ST	90042	1	151-5A229  68	5492015027	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.11107	-118.1894	ALTERATIONS IN THE PHARMACY SECTION OF A  CVS STORE-NEW LUMINAIRES AND CIRCUITSPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33121	10041-10000-10217	8180 W MELROSE AVE	90048	5	141B173   468	5528011036	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	PIN	34.0834491	-118.36781879	T-24 lighting plan check for remodeled tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33122	14041-20000-07232	6430 W SUNSET BLVD	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED FROM THIS PERMIT. EXISTING OFFICES NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33123	13041-10000-34795	1888 S CENTURY PARK EAST 550	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.06104	-118.41402	T24 PART 6 ENERGY LIGHTING WORK FOR (E) HIGH-RISE BUILDING. WORK WILL BE DONE ON 5TH FLOOR. PROJECTED LIGHTIN AREA IN SCOPE OF WORK IS APPROX. 5840 SQ FT. EMERGENCY FIXTURES WILL BE FED VIA (E) EMERGENCY CKT(S). SCOPE OF WORK < 400A. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33124	18041-10000-05943	19500 W PLUMMER ST # 8	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Issued	04/19/2018 12:00:00 AM	ADDRESS	34.2426	-118.55846	IN A VACANT EXISTING RETAIL SPACE, NEW PANELS AND AN EMERGENCY LIGHTING CIRCUIT IS INSTALLED. FUTURE TENANT WILL DEVELOPE THE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33125	17041-30000-30251	145 S LA BREA AVE	90036	5	138B181  1064	5513019040	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.07229	-118.34423	Plan check for Title 24 only in existing space T.I. in retail space new lighting fixtures. Total area: 2951 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33126	11041-10002-16708	143 N WESTERN AVE	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.07428	-118.3095	NEW 800A SERVICE AND CIRCUITS FOR A GROUP OF 6 COMMERCIAL BUILDINGS.  MAIN SERVICE IS IN BUILDING 4558 W. COUNCIL ST.  OTHER BUILDINGS (4556 W. COUNCIL AVE.,     147 N. WESTERN AVE,      149 N. WESTERN AVE,    151 N. WESTERN AVE.) WILL BE ON SUPPLEMENTAL PERMITS TO THIS.     THIS APPLICATION IS FOR 143 N. WESTERN AVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33127	19041-10000-33951	7725 N BOTHWELL ROAD	91335	3	189B117   953	2116008031	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.21095	-118.56137	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15 MODULES (Q-CELL 285) WITH 15 IQ7 MICROINVERTERS.  SYSTEM SIZE IS 3.75KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33128	14041-20001-03590	11508 N JENNY LANE	91344	12	213B129   269	2601040070	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	02/15/2014 12:00:00 AM	ADDRESS	34.27983	-118.52014	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 4 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33129	13041-10002-21459	1825 N BRONSON AVE 1-33	90028	13	150A191   280	5586027006	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			PC Approved	09/26/2014 12:00:00 AM	ADDRESS	34.10425	-118.31823	power and energy. APARTMENT BUILDING. REPLACING 40 PANELS, 33 of 40 ARE UNIT PANELS.  EXISTING BRANCH CIRCUITS TO REMAIN, RECEPTACLES TO BE REPLACED IN THE SAME LOCATION. Changes on plans include AFCI breakers, fully rated for 32kaic, and delta load calcs9-8-14     m.z.  CHANGES MADE TO PREVIOUSLY APPROVED SET. ALL FLOOR PLANS , CONDUITS  ETC.----	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33130	15041-10000-38438	500 S MATEO ST	90013	14	127-5A217  67	5163018005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM			Reviewed by Supervisor	12/02/2015 12:00:00 AM	ADDRESS	34.04146	-118.23294	Full PC for an existing Multi use commercial building. New 2000 A service. All equipment is new. Total sq ft = 15509	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33131	14041-20000-28051	17051 W PARTHENIA ST	91325	12	195B133   431	2690010005	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Closed	05/20/2016 12:00:00 AM	ADDRESS	34.22865	-118.50434	PV1.  Install 5.61 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33132	12041-10000-28623	5507 W HOLLYWOOD BLVD	90028	13	148-5A193 129	5544005024	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM			Reviewed by Supervisor	01/10/2013 12:00:00 AM	ADDRESS	34.10192	-118.30983	CHECK IF THEY FILED FIRE ALARM VARIANCE BEFORE APPROVAL?New single story retail Bldg. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33133	17041-10000-13367	5455 N VAN NUYS BLVD	91401	4	174B149  1115	2249003019	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.17003	-118.44902	T24 ONLY, REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 33400 SQ FT, OUTDOOR AREA.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33134	16041-20001-22983	9620 N WHEATLAND AVE	91040	7	201B177   448	2544006052	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM			PC Approved	07/21/2016 12:00:00 AM	ADDRESS	34.2435	-118.35835	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 15.2kW with 56 modules and 2 inverters(7.6kW)}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33135	17041-20000-20854	10550 W FONTENELLE WAY	90077	5	147B149   401	4370018030	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Info Complete	05/18/2018 12:00:00 AM	ADDRESS	34.09836	-118.44826	New 1200 A 120/240V service and distribution for major remodel of SFD - the permit application for this phase includes service and guard/security house.  Building permits under 16014-10000-01649 for the main house addition/remodel and 15010-10000-02451 for guard house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33136	11041-20001-04235	2614 W 7TH ST	90057	1	133-5A201 297		C2-2, R4-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	Plan check for revision to approved plans. Delta 3 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33137	19041-10000-29457	1143 N ILIFF ST	90272	11	129B129   282	4423006017	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.05065	-118.51989	NEW ROOF MOUNTED 9.9 KW  PV SYSTEM WITH 30 PV MODULES, 30 ENPHASE MICROINVERTERS  AND A TESLA POWER WALL ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33138	15041-20002-05476	225 S LINCOLN BLVD	90291	11	111B145   529	4240019061	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.00183	-118.46926	02/23/2016 Plan check for a lost set of plans. Plan check for Title 24. Project scope has remained the same. *****Previous Work Description*****Plan check for Title 24 only. Project site is existing commercial space (Whole Foods). Total lighting area = 2,594 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33139	19041-20000-43576	5800 W SUNSET BLVD BLDG 11	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.09728	-118.31693	Power and lighting for new equipment room enclosure.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33140	14041-20001-17906	12000 W IDAHO AVE 1-8	90025	11	126B145   893	4259003006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM	ADDRESS	34.03918	-118.46049	Changes to approved set.  Relocation of inverters to elecrical room.*****Previous Work Description*****pv2 commercial roof top. 37kw	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33141	12041-20000-26720	6633 N TOPANGA CANYON BLVD	91303	3	180B101   368	2139023027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	02/19/2013 12:00:00 AM	ADDRESS	34.19037	-118.60613	Change to lighting to an existing Chase Bank.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33142	12041-20000-08128	1905 S ARMACOST AVE	90025	11	123B149   235	4259020005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	06/11/2012 12:00:00 AM		Permit Finaled	09/18/2012 12:00:00 AM	ADDRESS	34.03603	-118.45531	Remodel building to become a school.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33143	13041-10001-22279	17440 W WEDDINGTON ST	91316	5	171B129   128	2257001015	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.1666	-118.51372	EXPEDITED PLAN CHECK PER APPLICANT REQUEST.(((PV1.  INSTALL 10.29 KW DC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN SERVICE PANEL.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33144	17041-20000-06094	10924 N TOPEKA DR	91326	12	210B121   796	2718012035	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.2682	-118.54529	Plan check for a PV1 roof-mounted PV system. System size is 4.6 kWac and consists of (14) AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33145	19041-20000-18706	20500 W BIRMINGHAM WAY	91326	12	213B109   807	2701097001	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	11/23/2019 12:00:00 AM	ADDRESS	34.28293	-118.581	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6.3KW DC/5.56KW AC. SCOPE OF WORK INCLUDES (18) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS, AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33146	13041-20000-00622	1724 N HIGHLAND AVE 1-270	90028	13	148-5A185  63	5547011031	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.10238	-118.3385	New lights and receptacles in an existing commercial space.  NOT a 1st-Time Tenant, load is less than 400 amps, and occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for T-24.  NO Emergency lighting for this Plan Check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33147	14041-20000-16592	20307 W VIA SANSOVINO	91326	12	219B113   269	2701061009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.29685	-118.57578	PV1.  Install 6.86 kW roof-mounted, utility-interactive PV system.  Transformerless inverter: SunnyBoy 6000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33148	16041-10001-10062	2112 W SUNSET BLVD Build. B	90026	13	139-5A207 108	5402035003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM			PC Approved	05/08/2017 12:00:00 AM	ADDRESS	34.07733	-118.26419	Changes to an approved set of plans. All changes are cloued. Changes include and changing lighting fixture from LED to flourescent.  Updated Title 24 calculations and revised emergency photometrics.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33149	16041-20001-42400	14596 W DEERVALE PL	91403	4	162B149   432	2275031013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.13889	-118.4527	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.9 kWac and consists of (33) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33150	16041-10000-41205	15210 W SHERMAN WAY	91405	6	183B145   102	2220001022	R3-1L, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.20097	-118.46451	PC for title 24, outdoor. Remove HID fixtures and replace with new LED fixtures. Total sqft = 14250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33151	12041-10000-03782	7800 N VINELAND AVE	91352	6	189B173   634	2409010025	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.10	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.21231	-118.37013	Outdoor lighting for 43530 s.f. of  parking lot. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33152	13041-10001-05854	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.11883	-118.2495	Revision to approved set noted under Delta 10 and Delta 13.consist of: relocate branch circuits, add new loads& receptacles, Update panels schedule, revise lighting plan and T-24.<<PLAN CHECK FOR POWER AND ENERGY LAPD MAINTENANCE BUILDING. PARTIAL DEMO OF EXISTING BUILDING. POWER SUPPLIED FROM 2000A SERVICE LOCATED OUTSIDE, PLAN CHECK UNDER #13041-10000-05854. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33153	17041-20000-40625	730 S LA BREA AVE	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.06136	-118.3441	Plan check for power and energy. Project site is an existing commercial building. Project scope is a first-time tenant. Total lighting area = 4,292 sq. ft.Note: Building application has been generated under 17016-20000-30241	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33154	17041-10000-42427	12105 W WATERFRONT DR C1-107	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	33.98095	-118.40764	Full plan check for a first time tenant (gym) T.I located in a (5) story building. Scope includes new equipment and lighting. Total area is (3105) SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33155	17041-10000-37367	5833 S BROADWAY	90003	9	108B201  1430	6005007007	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Un		2392.01	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	09/10/2021 12:00:00 AM	ADDRESS	33.9887	-118.27849	"PC for power and energy for new resturant building ""Tacos El Gavilan"". PC for new 120/208 800A service with new service equipment,  five new panels, lights, receptacles and equipment. Total indoor area is 4098sqft and outdoor is 12780sqft. B# 17010-10000-03909."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33156	14041-20000-34560	424 W 11TH ST	90731	15	015B201   555	7456001013	R2-1XL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	33.73433	-118.28631	PV2. ROOFMOUNTED SOLAR SYSTEM. COMMERCIAL. SYSTEM SIZE: 3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33157	12041-10000-30570	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.0446	-118.21143	PLAN CHECK FOR POWER AND ENERGY FOR MEDICAL BUILDING TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33158	18041-10000-27043	3800 S VERMONT AVE	90037	9	117B197   615	5037028912	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Issued	10/30/2018 12:00:00 AM	ADDRESS	34.01684	-118.29134	FULL PC FOR POWER AND ENERGY FOR LUCAS MUSEUM (PHASE 2). SCOPE INCLUDES INSTALLING 4160V MEDIUM VOLTAGE EQUIPMENT, SWITCHBOARDS, PANEL BOARDS, CIRCUITS, AND LIGHTING.  THIS PLAN REVIEW IS FOR EQUIPMENT OUTLINED ON THE SINGLE LINE LOCATED IN FIRST FLOOR TO THE 5TH FLOOR. TOTAL AFFECTED AREA IS 1335766 SQ. FT. NOTE: PHASE 1 IS UNDER PCIS#18041-10000-21031	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33159	15041-20000-17390	6436 W HAYES DR	90048	5	132B173   162	5088008006	R2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.06079	-118.37014	Plan check for PV roof mounted system. System size: 5kW with 22 modules and 1 inverter(5kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33160	13041-10000-11805	19300 W RINALDI ST SUITE H	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.27414	-118.55457	TI to a chiropractor's office (healthcare facility).  Addition of receptacles.  New switches and lighting.  Single story building, tenant's space is 932 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33161	14041-10000-29139	12011 W SAN VICENTE BLVD 700	90049	11	129B141   153	4404023019	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.05243	-118.4735	OFFICE TENANT IMPROVEMENT (1250 SQ. FT. :PLAN CHK IS FOR TITLE 24NON-HIGH RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33162	13041-10000-24713	14722 W MAGNOLIA BLVD UNIT 3	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	PV2.  Instal 2.4 kW DC roof-mounted solar array of 10 modules, interconnect with apartment unit panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33163	11041-10000-27507	505 S SAN PEDRO ST	90013	9	127-5A213 232	5148012019	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			12/28/2011 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.04392	-118.24444	NEW  6  STORY  108 UNIT AFFORDABLE APARTMENT BUILDING PER DIR 2011-1209-DD.  THE BUILDING HAS TYPE I CONSTRUCTION FOR THE SUBTERANEAN PARKING BASEMENT AND ON-GRADE FLOOR AND TYPE IIIA FOR THE 5-STORY APARTMENT ABOVE.(Variance for deferred approval of fire alarm system filed. Total  P/check fees need review.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33164	19041-20002-19099	13262 W GALEWOOD ST	91423	4	162B157   331	2385006034	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	06/19/2020 12:00:00 AM	ADDRESS	34.14224	-118.42152	$0 PLAN CHECK AND PERMIT FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET, CHANGES MADE TO ALL PAGES. CHANGE MADE TO PV ROOF TILE MODEL, REMOVING/REPLACING ALL PREVIOUS INVERTERS WITH 5.2 KW SOLIVIA INVERTERS, ADDING A 5.2 KW INVERTER, AND CHANGE OF SYSTEM SIZE FROM 30.02 KW DC/26.6 KW AC TO 27.8435 KW DC/26 KW AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33165	15041-10000-12982	1925 S CENTURY PARK EAST # 1975	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 2527.  SCOPE OF WORK TO BE PERFORMED IN SUITE 1975.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33166	19041-10000-04480	1060 W EXPOSITION BLVD	90007	8	117B197  1265	5037015***	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.018	-118.29332	Plan check for a central station sprincler monitoring system located inside a commercial building with full notification. Scope includes (1) fire alarm panel, (1) control panel, and (63) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33167	12041-10000-10693	3640 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	06/12/2012 12:00:00 AM	ADDRESS	34.01993	-118.37802	New lighting for a modular rooms.  Load is less than 400A per applicant.  PLAN CHECK ONLY for Energy lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33168	14041-20000-28743	14723 W COVELLO ST	91405	6	186B149   244	2218002015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.20766	-118.45399	PV1 SFD. TOTAL SYSTEM SIZE 6.04KW AC USING MICROINVERTER SYSTEM. USING STANDARD PLAN. TOTAL OF 28 MODULES. ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33169	06041-10014-09913	1633 N LA BREA AVE	90046		147B181   287	5548008010	C4-1VL-SN		Hollywood	Hollywood Hills West			Electrical	Electrical	Apartment			11/10/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	34.10058	-118.34527	Delta 20 on Dwgs. E5.1 and E5.2, revised load balance for phases AB, BC, and CA at meter banks.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33170	19041-30000-22147	5569 W ADAMS BLVD	90016	10	123B177   971	5048001059	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.03262	-118.36433	Plan check for Title 24 only. Project site is the 2nd floor corridor of an existing commercial building. Indoor lighting for the retail spaces on the 1st floor is not part of this scope of work. Project scope is a tenant improvement. Total lighting area = 456 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33171	10041-20000-23850	6600 N TOPANGA CANYON BLVD #2067	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	01/31/2011 12:00:00 AM		Permit Finaled	03/03/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check power and energy (includes sign lighting) for first time tenant for suite #2067 (Yankee Candles)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33172	16041-20000-45449	500 S GRAMERCY PL	90020	4	135B193   671	5504029017	R4-2	Central	Wilshire	Greater Wilshire		2117.04	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.0651	-118.31263	PV2.  Install 18 kW AC roof mounted grid tied PV system.  (66) modules with (3) 6 kW transformerless central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33173	19041-30000-00193	22601 W CASS AVE	91364	3	171B097   858	2075022004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.16252	-118.6186	Plan check for a PV1 roof-mounted PV system. System size is 9.15 kWdc/7.6 kWac and consists of (1) inverter, (30) modules, (1) load center, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33174	19041-30000-37098	5569 W ADAMS BLVD	90016	10	123B177   971	5048001059	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.03262	-118.36433	T-24, PLAN CHECK ONLY. TENANT IMPROVEMENT TO (E) RETAIL. REMODEL OF EXISTING TWO STORY MIXED USE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33175	18041-10000-42813	1888 S CENTURY PARK EAST #1125	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.06104	-118.41402	Tenant improvement to existing office in Suite #1125. Installing Lights. T-24 Energy Only.Building Permit: 18016-10000-30262	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33176	10041-20000-05696	6711 N VAN NUYS BLVD	91405	6	180B149   185	2236010002	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02, 1281.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/10/2010 12:00:00 AM	ADDRESS	34.19252	-118.44905	INTERIOR T.I. this plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33177	18041-10000-46488	2214 S VIRGINIA ROAD	90016	10	123B185   233	5061003026	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Closed	12/18/2018 12:00:00 AM	ADDRESS	34.03604	-118.33692	Changes to an online permitted pv plan. The scope of work includes changing the central inverter from Delta Solivia 5.2KWac to a Solar Edge 10KWac. **Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling**Permit was pulled online #18041-90000-30355	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33178	19041-10000-35848	10657-10659 W MOORPARK ST	91602	4	165B177   315	2423004012	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			09/10/2019 12:00:00 AM	10/03/2022 12:00:00 AM		Issued	10/03/2022 12:00:00 AM	ADDRESS	34.15049	-118.36341	FULL POWER PLAN CHECK FOR A 1200 A, 120/240 V, 3-PHASE 4-WIRE SYSTEM. SCOPE OF WORK INCLUDES PANELS, MOTORS, CIRCUITS, AND LIGHTING. (LOW RISE) TOTAL AFFECTED AREA: 11,123 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33179	19041-20000-36130	4546 N ALLOTT AVE	91423	4	168B157   857	2360015038	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Issued	09/11/2019 12:00:00 AM	ADDRESS	34.15355	-118.42776	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.34 KW DC/11.4 KW AC. SCOPE OF WORK CONSISTS OF (36) PV MODULES, A 11.4 KW INVERTER, AND A 125A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33180	16041-10000-28002	10730 W PICO BLVD	90064	5	126B157   760	4255028008	C2-1VL, PB-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.04128	-118.42564	T-24, PC for eenrgy only. Interior T.I. at 3rd level to an exsiting retail space. Scope includes new lights and receptacles. Total affected area is 778 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33181	15041-10000-06010	237 W 30TH ST	90007	9	120A205   152	5122011009	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.02323	-118.27363	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33182	18041-10000-26142	2010 S CENTURY PARK EAST Parking	90067	5	132B161    28	4319001803	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.05986	-118.413	TI IN AN EXISTING PARKING STRUCTURE ON THE GROUND LEVEL. INSTALLING NEW LIGHTS.  T-24 ENERGY ONLY.Building Permit Number _______________________	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33183	13041-20000-29381	3641 S WATT WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.02033	-118.28801	PC FOR T24 ENERGY ONLY. NEW LIGHTING. NON HEALTH CARE FACILITY. WORK DONE ON 2ND AND 3RD FLOOR. ALL WORK ON THE INSIDE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33184	12041-10000-19753	555 W 5TH ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Expired	09/16/2014 12:00:00 AM	ADDRESS	34.05016	-118.25369	Ti for confrence room on the 40th and 41st floors,  replacing power table with new ones office furnitures shall be listed  by city of la.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33185	17041-10000-04363	3839 W WILSHIRE BLVD	90010	10	132B193    36	5503031018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Issued	02/27/2017 12:00:00 AM	ADDRESS	34.06186	-118.31007	PC for power only for a temparary power service for Metropolitan Transportation Authority. Equipment is located in adjacent leasing lot falling under LA city jursidiction. Temporary service is rated at 600A 3ph 4w.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33186	11041-20000-08129	425 S PALOS VERDES ST	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	33.74102	-118.28156	Roof mounted P.V with 155.52 KW for Port of L.A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33187	14041-20000-15999	10921 W ART ST	91040	7	201B173   206	2542011008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.24865	-118.36837	PLAN CHECK ONLY FOR AS BUILT DESGIN. NOTE: STANDARD PLAN MAY NOT BE USED. THIS SYSTEM IS CONNECTED TO A 400A SERVICE POINT. INSPECTOR TO VERIFY PROPER AIC OF AC DISCONNECT AT SERVICE PANEL. PLAN CHECK OF CUSTOM PLANS TO REPLACE APPROVED STANDARD PLAN.ORIGINAL PERMIT APPLIATION ((14041-20000-10828))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33188	18041-20000-17807	3144 N CORDA DR	90049	11	159B137   486	4490004049	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	03/23/2019 12:00:00 AM	ADDRESS	34.1296	-118.48812	$0.00 FEES DUE TO SENATE BILL 1222, AND BL1414Plan check for PV roof mounted system, system size: 19.6kWac with 66 modules and 66 microinverters connected to 400A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33189	19041-10000-09603	445 S FIGUEROA ST STE 2970	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLAN CHECK FOR TITLE 24 FOR AN OFFICE TOTAL EFFECTED AREA 1242 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33190	13041-10000-32625	10325 N LUBAO AVE	91311	12	204B113   128	2708017035	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.2582	-118.56881	PV1. ROOFMOUNTED PHOTOVOLTAIC SYSTEM TRANSFORMERLESS UNGROUNDED. SYSTEM SIZE: 6.50KW DC. USING (26) RENESOLA SOLAR MODULES JC250M, (26) POWER OPTOMIZERS, (1) SOLAREDGE INVERTER SE6000, AND PV WIRE USING LA TEST LAB APPROVED INDUSTRIAL WIRE PVX1019	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33191	16041-10000-31820	2010 E 7TH ST	90021	14	124-5A217 259	5166015004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.03441	-118.23187	PC for energy only to existing building. Change of use from manufacturing to gallery. new lighitng. pc for entire tenant t24 compliance	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33192	14041-20000-00579	22910 W VANOWEN ST	91307	12	180B097    24	2038040027	QC2-1VL	South Valley		West Hills		1352.01	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.19354	-118.62637	pc and permit for reinspection of 1000A service section. temp connections to be reconnected to main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33193	18041-20001-06749	7308 N COLDWATER CANYON AVE	91605	2	186B161   562	2324005032	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.20344	-118.41361	04-136-2018 Changes to permitted set of plans. Changes include  reduce scope of work from full T.I. to restaruant to rest room area and emergnecy lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33194	17041-10000-37203	11160 W VICTORY BLVD	91606	2	180B173   898	2336019021	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.18651	-118.37436	REPLACING OUTDOOR HID WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33195	13041-10000-08048	8816 W SATURN ST	90035	5	129B169   203	4305014057	R1-1-O	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.05299	-118.38462	PV1 for single-family dwelling.  Microinverter standard plan application.  {Microinverter: Enphase M215-60-2LL-522-NA} {24 modules: Conergy PH 230P-255P}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33196	16041-10000-30458	2200 W COLORADO BLVD	90041	14	162A221   402	5686002006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.13894	-118.2145	PC FOR TITLE 24, ENERGY ONLY. TOTAL AREA OF 20025 SQ.FTINDOOR 1400S SQ.FT  OUTDOOR 18625 SQ.FTA COMMERCIAL BUILDING (AUTO REPAIR).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33197	18041-10000-35102	117 N SARATOGA ST	90033	14	127-5A225 343	5180016038	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.04204	-118.20465	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33198	12041-10000-25588	6060 W CENTER DR	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	33.97602	-118.39073	Title 24 for a corridor and emergency lights. 1225 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33199	15041-10001-22906	3425 W MONT CLAIR ST	90018	10	123B189  1033	5052013016	RD5-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.02976	-118.32212	EXPEDITED FEES FOR ROOF MOUNTED SYSTEM.  (((PV 2, MULTI UNIT APARTMENT. ROOF MOUNTED SYSTEM WITH (8) MODULES AND 1 -3.0KW INVERTER. TOTAL SIZE 2.12 KW. (8) KYOCERA #KU2656ZPA(1) PV1-3.0-OUTD-S-US-Z-A)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33200	16041-20000-44862	1710 S ROBERTSON BLVD	90035	5	129B169   970	4303005032	C2-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial	17	Restaurant	12/21/2016 12:00:00 AM			PC Approved	12/21/2016 12:00:00 AM	ADDRESS	34.04844	-118.38544	Plan check for energy only. New restuarant tenant space. New lighting (incl. emergency). 1,090sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33201	11041-20000-06176	7000 W HOLLYWOOD BLVD #125, 213,-113,108	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.10137	-118.34182	Per applicant request, plan check for power only.  New added load less than 400 amp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33202	16041-10000-30140	10250 W SANTA MONICA BLVD 2865	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	TI, new tenant , power and T 24 for Westfiled century city - Sketchers space no. 2865Total area: 3,222 sq.ft. (2) panels, total load < 200A.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33203	14041-10000-19080	13031 W JEFFERSON BLVD 900	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	33.97451	-118.42531	PC FOR POWER AND ENERGY. TI. VERIZON OFFICE. TOTAL AREA 44506 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33204	10041-10000-24629	1213 E PLAZA DEL SOL	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			12/13/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04894	-118.22611	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33205	19041-10000-06210	11099 S LA CIENEGA BLVD #195	90045	11	087B173    10	4129036910	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	07/06/2022 12:00:00 AM	ADDRESS	33.93534	-118.37106	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33206	15041-10001-00343	550 S HOPE ST 8TH FLOOR	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	Changes made to approved plans due to architectural revisions of the tenant space.  PC FOR ENERGY ONLY. PARTIAL FLOOR OFFICE BUILD OUT. TOTAL AREA 7216 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33207	16041-10001-43558	10250 W SANTA MONICA BLVD UNIT 1780	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	This is Plan check only: Changes to approved set noted under Delta-4 and 6:    (1)Revise lighting switchbank detail.  T24 form is not affected.   (2)Revise AHU load and reduce breaker size	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33208	17041-20002-23935	21051 W SUPERIOR ST	91311	12	201B105   175	2746003003	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.24647	-118.59228	09/28/2017 Changes to an approved set of plans. PV system size has increased to 22.8 kWac and consits of (3) inverters. Module count has not changed.Note: No change was made to the PV module layout and as such, LAFD layout approval is not required once again. *****Previous Work Description*****EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on commercial building.22.8kW ungrounded system. (66) 345W pv modules.Each module has a 400W power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33209	19041-10000-21793	152 N RAMPART BLVD	90026	13	138A203   446	5157001009	R3-1	Central	Westlake	Echo Park		2086.20	Electrical	Electrical	Apartment			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	34.07074	-118.27579	PLAN CHECK FOR A NEW FIRE ALRAM SYSTEM IN AN APARTMENT COMPLEX. SCOPE INCLUDES NEW FA CONTROL PANEL, ANNUNCIATOR, COMMUNICATOR AND 26 DEVICES. 2 x 12V 7AH batteries used	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33210	17041-10000-38267	920 S SOTO ST	90023	14	124-5A221 406	5189009034	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Issued	10/24/2017 12:00:00 AM	ADDRESS	34.03368	-118.21586	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33211	14041-20001-15222	20406 W LORNE ST	91306	3	189B113   226	2107003010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.21727	-118.57768	Fee for expedite only.*****New roof mounted system with size 3.06	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33212	14041-10000-15331	3045 S MOTOR AVE	90064	5	123B161   260	4318025004	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.03573	-118.40942	PV1 3.3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(12) inverters: {MICROINVERTER: ENPHASE ENERGY M250-60-2LL-S22]}]. [(12)modules: {solarworld SunModule SW-275 mono}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33213	11041-10000-27270	470 E SWINFORD ST	90731	15	021B201   196	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	33.74945	-118.2748	"Cruise terminal bldg. for ""Catalina Express""(Change of Use from banquet hall to banquet hall/cruise terminal building with offices, cafe, and cocktail bar. Work includes interior tenant improvement, storefront remodel and door/window replacement and re-stripe the parking lot for H/C and green auto parking spaces.)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33214	19041-10000-16203	1522 N FAIRFAX AVE	90046	4	147B177   871	5551019003	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.09873	-118.36135	(ePlan) Install (1) 13.5 kWh Tesla Powerwall for Battery Backup on a single family home. There's an (E) 3.3 kW AC PV system. Also (2) New 125Amp Generation Panel and Critical Load panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33215	13041-10000-01464	18251 W ROSCOE BLVD	91325	12	192B125   630	2786015018	(Q)CR-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM			PC Approved	01/18/2013 12:00:00 AM	ADDRESS	34.22097	-118.53126	T24 FOR OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33216	15041-20000-17244	14861 W BESSEMER ST #4	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	34.18089	-118.45728	Plan check for retail T.I. Title 24 only. Total area: 2,042 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33217	19041-20000-00604	13567 W GILMORE ST pv1	91401	2	180B157   795	2329006014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.18782	-118.42916	pv1install roof mounted pv system sized 3.9KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33218	15041-10000-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	REPLACING DISTRIBUTION BOARDS AND PANEL BOARDS AS PART OF SWITCHGEAR UPGRADE AT TERMINAL 7; SERVICE REMAINED THE SAME	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33219	13041-10000-17101	150 N LARCHMONT BLVD	90004	4	138B189   715	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM			PC Approved	08/14/2013 12:00:00 AM	ADDRESS	34.07452	-118.32343	PLAN CHECK FOR TITLE 24 PART 6 AND EMERGENCY LIGHTING. A PERMIT HAS ALREADY BEEN OBTAINED UNDER APPLICATION NUMBER 12041-20000-27437.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33220	13041-10001-30807	718 N HIGHLAND AVE	90038	4	141B185   470	5524011026	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.08414	-118.33839	plan check for energy only. changes to approved: changed lighting (added a luminaire type and removed some lights)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33221	12041-10000-01691	6601 S CENTER DR WEST #200	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Approved	01/24/2012 12:00:00 AM	ADDRESS	33.97997	-118.39375	T.I. to an existing office space on a high-rise building.  Relocating lights.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Entire 2nd floor, suite 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33222	18041-10000-10557	17383 W SUNSET BLVD A400	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Info Complete	05/09/2018 12:00:00 AM	ADDRESS	34.03917	-118.55529	PC FOR TITLE 24 ENERGY ONLY FOR INTERIOR OFFICE REMODEL.SCOPE INCLUDES NEW PANEL CIRCUITS EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 3310 SQ.FTB# 18016-10000-07153	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33223	18041-20000-30201	1402 N CAMPUS ROAD	90042	14	156A223   169	5476019016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Closed	02/24/2023 12:00:00 AM	ADDRESS	34.12247	-118.21072	Power and lighting for addition and change of use from (E) duplex to hydroponic agricultural enterprise.  New 600A 240/120V 1ph-3w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33224	18041-20000-25359	710 S SANTA FE AVE	90021	14	124-5A217 282	5166002018	(Q)C2-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.03414	-118.22981	Plan check for a fire alarm system for a 2-story commercial building. Fire alarm system consists of (1) FACP and (36) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33225	16041-20001-21757	7920 N CHASTAIN AVE	91335	7	213B173   399	2529020007	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	34.21425	-118.52365	EXPEDITEPV1ADDITION TO AN EXISTING SYSTEM.  ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33226	18041-30000-02992	11859 W WILSHIRE BLVD #100	90025	11	129B145   838	4265013041	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.04724	-118.46388	Plan check for power and energy change of use from office to Medical office, with no surgical procedures. Total area:3500 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33227	14041-10000-11563	441 S HEWITT ST	90013	14	127-5A215 339	5163022020	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.04238	-118.2353	Title 24 for commercial warehouseArea = 8469 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33228	16041-10000-05875	15350 W SHERMAN WAY STE 140	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.20099	-118.46808	T-24, TI TO AN OFFICE SPACE IN A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ.FT. 3742.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33229	16041-10000-15489	11150 S MAIN ST	90061	8	087A205    88	6073024013	C2-1VL	South Los Angeles	Southeast Los Angeles			2411.10	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Expired	08/15/2018 12:00:00 AM	ADDRESS	33.93376	-118.27371	PC FOR POWER AND ENERGY. T.I FOR WHAREHOUSE. UPGARDING SERVICE TO 800A ND SWITCH GEAR, AND ADDITION OF 6 200A PANELS. TOTAL AREA 2641 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33230	15041-10000-31385	3044 S DANALDA DR	90064	5	123B165   126	4316015011	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Expired	10/18/2017 12:00:00 AM	ADDRESS	34.03655	-118.40348	PV1 6.0KW roof-mounted system with (26) Kyocer KU265 moudules, and (1) PVI-6000-OUTD  inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33231	16041-10002-45776	380 WORLD WAY NBHS	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	4/5/19 SUPPLEMENTAL CHANGES TO APPROVED SET OF LAX PROJECT DELTA DCN-103.***************************PREVIOUSE WORK DESCRIPTION**************************02-06-2018 Changes to an approved set of plan LAX Project 5 Midfiled Satallite Concourse North(MSCN) NBHS. Changes include circuit revision and lighting layout. Changeshas been clouded and apply to delta 1 only. ***************************Proviouse Work Description**********************************Plan check for power and Title 24.  Provide normal and emergency power to North Baggage Building in LAX.Building permit #16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33232	10041-10001-15049	6080 W CENTER DR 11th&12th-Floors	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM			PC Info Complete	09/07/2010 12:00:00 AM	ADDRESS	33.97713	-118.39172	"TI in an existing office area on the 11th & 12 Floors.  Fire Alarm Permit was issued to ""Detection Logic"".  Plan Check is for T-24 Energy Calcs & Emergency lights.  Permit was issued under 10041-90000-15049"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33233	17041-10000-39293	1229 S KINGSLEY DR	90006	10	129B193  1137	5080027007	R3-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Apartment			10/31/2017 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.04817	-118.30334	PC FOR NEW 3-STORY 6 UNIT APARTMENT & ROOR DECK OVER PARKING GARAGE.NEW SERVICE RATED AT 800A 120/240V.TOTAL AFFECTED AREA 6920 SQ.FT. B#17010-10000-04216	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33234	12041-10000-15220	4700 W SUNSET BLVD	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01, 1913.00	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.09788	-118.29194	Power for new DDC controllers for an existing Medical Office.  Full plan check for Power and Energy.  Building is not licensed by the state per applicant.  NOT CHECKED FOR OSHPD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33235	14041-20000-35149	7033 N MIDDLESBURY RIDGE CIR	91307	12	183B089   161	2028046014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.19997	-118.64599	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main breaker to 150A.System size: 10kW (5+5). Ungrounded system.40  250W pv modules across 6 strings (inv1 has 7+6+6; inv2 has 7+7+7).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33236	19041-10000-05219	2121 S AVENUE OF THE STARS #2980	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.05554	-118.41342	INTERIOR OFFICE TI. OF 2,292 SQ FT IN SUITE #2890. INSTALL NEW LIGHT FIXTURES. T-25 ENERGY ONLY. BUILDING PERMIT: 19016-10000-02845	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33237	16041-30000-25326	3831 S HUGHES AVE 5th floor	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.02242	-118.39823	Plan check for Title 24 only. Project site is the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,540 sq. ft.Note: Building application has been created under 16016-10000-12414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33238	15041-20000-18659	380 WORLD WAY Terminal 1-Space T93	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Title 24 only. Project site is an existing commercial space (Space T93) within the Arrivals Terminal (Terminal 1) at LAX. Project scope is two illuminated sign for a Pinkberry. Total sign lighting area = 15 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33239	18041-30000-14071	21514 W SATICOY ST	91304	3	186B105   164	2111005038	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Apartment			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.20807	-118.59943	Plan check for a fire alarm system for a 3-story apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (109) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33240	15041-10000-39756	14859 W BESSEMER ST	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.18089	-118.45722	PC FOR POWER, SCOPE OF WORK INCLUDES CHANGING OF SWITCHGEAR, 600AMP, TO EXISTING LOAD IN A COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33241	18041-20000-27463	11451 N GLADSTONE AVE	91342	7	213B165   586	2531015010	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Re-Activate Permit	11/07/2019 12:00:00 AM	ADDRESS	34.27833	-118.39358	Plan check for a PV1 roof-mounted PV system. System size is 13.02 kWdc and consists of (1) 11.4 kWac rated inverter and (42) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33242	14041-20000-20289	834 N KENMORE AVE	90029	13	144B197  1385	5538014008	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.08678	-118.29687	New roof mounted PV system with Optimizers.  Total system size 7.6KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33243	11041-10000-26855	3327 E SABINA ST Bldgs A, B-& C	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			12/16/2011 12:00:00 AM	12/16/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Changes to approved plans. ((((( additional 72 devices and control panel is located in building c))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33244	12041-10000-06948	2300 W BEVERLY BLVD	90057	13	136-5A205 272	5154010034	C2-1	Central	Westlake	Westlake North		2085.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	ADDRESS	34.06761	-118.27314	remodeling inside existing restauranr ccupying single story building;plan chk s for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33245	14041-20000-12189	8736 N OAKDALE AVE	91324	12	195B113   441	2782027008	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.22946	-118.56654	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33246	18041-10000-35655	14148 W MAGNOLIA BLVD #105	91423	4	171B153   452	2248022005	C1-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.16471	-118.44179	PC FOR ENERGY ONLY, T.I. TO OFFICE SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TOTAL SQ. FT. 2301.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33247	11041-10000-10899	8708 W PICO BLVD	90035	5	132B169  1038	4303010003	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM			PC Approved	05/31/2011 12:00:00 AM	ADDRESS	34.05424	-118.38192	REMOVING AND REPLACING TWO OUTDOOR PARKING LOT LIGHTS IN AN EXISTING SUPERMARKET PARKING LOT.  T-24 FOR OUTDOOR LIGHTING, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33248	17041-10000-39824	6601 S CENTER DR WEST 7TH FLOOR	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	33.97997	-118.39375	PC FOR TI FOR 7TH FLOOR OFFICE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES INSTALLING NEW LIGHTS AND RECEPTACLES.TOTAL AFFECTED 2933 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33249	12041-10000-05435	960-968 E ELKLAND PL	90291	11	111B145   999	4243004036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			03/09/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99855	-118.45949	Two  story aparment , new fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33250	17041-20000-39323	510 S OXFORD AVE	90020	10	135B193   741	5503020026	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			10/31/2017 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Closed	12/18/2023 12:00:00 AM	PIN	34.06466373	-118.30747215	New 7-story, 89-unit apartment building with 2 levels of subterranean garage.  2500 A 208Y/120V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33251	13041-10000-20671	7164 W MACAPA DR	90068	4	153B181    13	5549007001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.1193	-118.34676	PV1 8.82KWdc 240V XFMR INV. 1STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 36) MOD: TRINA {TSM-245PC05.18}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33252	18041-10000-20281	10900 W WILSHIRE BLVD LEVEL 3	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	PC FOR INTERIOR TI OF ELEVATOR LOBBY, TENANT CORRIDOR AND RESTROOMS ON LEVEL 3 IN A HIGH RISE BUILDING FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 1367 SQ.FT. B#18016-10000-05056	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33253	19041-20000-50915	1442 N FORMOSA AVE	90046	4	147B181   721	5548018029	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			12/10/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Issued	03/03/2020 12:00:00 AM	ADDRESS	34.0974	-118.34615	T24 PLAN CHECK, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 835 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33254	13041-10002-13066	8900 N DE SOTO AVE BLDG 101S	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. DELTA 1 CHANGES ONLY. REMOVING HIP FURNACE ALONG WITH THE SUBSTATION 7. OTHER MINOR CHANGES ALSO.Plan check for new industrial facility. Pratt Whitney Rocketdyne. Building 101 South. PC fees per applicant. NOT methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33255	10041-10000-07664	11611 W SAN VICENTE BLVD 9TH FL	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.0541	-118.46261	REPLACING LUMINAIRES IN THE CORRIDOR AND RESTROOMS ON THE 9TH FLOOR;PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33256	14041-20000-34084	2435 N CREST VIEW DR	90046	4	153B169   273	5564015022	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM			Corrections Issued	12/10/2014 12:00:00 AM	ADDRESS	34.11606	-118.3896	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (2) inverters and (31) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33257	19041-10000-40970	2582 N LAKE VIEW AVE	90039	13	150A209   287	5438011014	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.10382	-118.25538	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 12 MODULES (SILFAB SLG 360), WITH 12 OPTIMIZERS (SE P370) AND 1 CENTRAL INVERTER   (SE 3800H-US). SYSTEM SIZE IS 4.32KWdc AND 3.8 KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33258	11041-10000-07144	1526 N EDGEMONT ST	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	ADDRESS	34.09898	-118.29599	NEW SERVICE TO SUPPLY EXISTING FIRE PUMP INSTALLATION AND  EXTERIOR LIGHTING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33259	14041-10000-18822	300 S SANTA FE AVE	90013	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	PLAN CHECK FOR POWER AND ENERGY.   FIRST TIME TENANT PER APPLICANT.BUILDING P# 14016-10000-09782. Tenant improvement for grocery store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33260	15041-20003-22144	7514 N HASKELL AVE	91406	6	186B141   235	2206013012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			03/15/2018 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.20712	-118.47477	3/15/2018changes to an approved set of plans.  changes noted delta 2.  changes include changing fully rated breakers to 42KAIC.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33261	16041-20001-42396	12149 N BELLANDO CT	91344	12	219B125    96	2601074006	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.29499	-118.52583	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (45) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33262	17041-10001-45474	5825 W SUNSET BLVD 2ND FLR	90028	13	147A191    51	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM			PC Approved	01/10/2018 12:00:00 AM	ADDRESS	34.09824	-118.3165	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 5181 SQ. FT. B#17016-10000-21312	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33263	14041-20001-01107	7301 N QUARTZ AVE	91306	3	186B117   864	2115010018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.20309	-118.56466	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.((expedite fees)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33264	16041-10000-19356	1755 N HIGHLAND AVE	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.10323	-118.33897	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO DELICATESSEN IN EXISTING HOTEL LOBBY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 965 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33265	14041-20000-33633	1304 N RONAN AVE	90744	15	033B205   217	7415007016	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	33.78884	-118.27263	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system.18  250W pv modules across two strings (9+9).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33266	12041-10000-19172	11668 W SHERMAN WAY	91605	6	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.20103	-118.38683	INSTALL A 500KVA TRANSFORMER AND A 500KVA UPS SYSTEM FOR THE LABORATORY EQUIPMENT IN A TWO STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33267	17041-20000-12911	6311 W ROMAINE ST	90038	13	144B185   737	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.08902	-118.32929	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33268	15041-10000-36530	1325 N SILVER LAKE BLVD	90026	13	142-5A205 365	5426002034	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM			PC Info Complete	10/30/2015 12:00:00 AM	ADDRESS	34.08398	-118.27206	Installation of new roof mounted solar PV array on new single family dwelling.  Total system size = 5 kWac.  Central inverter system.(20) MODULES-SUNMODULE PLUS SW 285(1) CENTERAL INVERTER-SUNNY BOY 5000 SMA AMERICANOTE: READY TO ISSUE AFTER BUILDING PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33269	18041-10001-41733	1901 S CREST DR	90034	5	126B169    95	4302007001	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	34.045	-118.38825	expedite per applicant request.(((Plan check for a PV1 8.4KW AC/ 10.4KW DC roof-mounted solar PV system with (32) modules, (2) inverters, (2) subpanels, and (2) energy storage system interconnecting through the main service.Note. Portion of the permit fee is paid under 18041-90000-33282. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33270	17041-20000-20091	20332 W KESWICK ST	91306	3	186B113    98	2114002010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.20957	-118.57649	Plan check for a PV1 roof-mounted PV system. System size is 12.1 kWac and consists of (35) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33271	18041-10007-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.26056	-118.35206	"DELTA ""2"" CHANGES TO APPROVED PLANS TO SHOW ACTUAL FIELD CONDITIONS FOR AN ADDITIONAL 200AMP AC DISCONNECT SWITCH @ 22KAIC, OUTSIDE OF THE BULDING WTH 200 AMP FUSES.<<<SYSTEM SIZE 11.0KWAC/ 16.8KWDC (OPTIMIZERS)SCOPE INCLUDES 42 MODULES WITH OPTIMIZERS AND 2 CENTRAL INVERTERS. EXSITING SERVICE AT 600A  120/240 >>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33272	07041-10002-27321	2311 W 10TH ST 1-27	90006		130-5A201  49	5136004016	R4-1		Westlake	MacArthur			Electrical	Electrical	Apartment			08/03/2010 12:00:00 AM			PC Approved	10/15/2010 12:00:00 AM	ADDRESS	34.05314	-118.28223	New 27 unit apartment with 2 subterranian parking and 4 level above grade (6 typical).  New service 1200amp, 120/240v, 1ph, 3w.  Plan check for power and energy.    Lost Appoved Plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33273	15041-10000-10458	2511 W 3RD ST	90057	13	135A203    96	5155033018	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.02	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.06525	-118.27685	TI TO AN EXISTING BUILDING, DIALYSIS CLINIC OSHPD-3. PC FOR POWER. I2.1 OCCUPANCY EXEMPT FROM ENERGY. PERMIT 2 OF 2 OF THE SAME PROJECT.  2ND CONTRACTOR WILL MAKE INSTALLATION FOR DIALYSIS EQUIPMENT.NOTE: PERMIT 1 OF 2 FOR PANEL UPGRADE IS UNDER PERMIT PCIS#15041-20000-42198/E15VN03502	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33274	16041-10000-40016	4500 N VAN NUYS BLVD H	91403	4	168A151   242	2265013026	C2-1VL-RIO, P-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.15325	-118.4485	PC FOR ENERGY ONLY. T.I FOR  OFFICE/RETAIL; LOAD<400A. TOTAL AREA 3436 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33275	16041-10002-04795	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	12/16/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	Changes to an approved set of plans, Changes include the revision of wiring to two (150HP) fire pump motors. Per Inspection request.(((PC FOR POWER AND ENERGY.  ADD THEATER STRUCTURE TO (E) MUSEUM/RESTAURANT/RETAIL/OFFICE BLDG. 2 NEW SERVICE WITH 3000A, 5000A , ADDITION OF NEW PANELS AND DEVICES. B# 13014-10000-03762	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33276	16041-20000-12065	11419 N PORTER RANCH DR	91326	12	213B113   325	2701072004	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.27861	-118.57253	Plan check for a PV2 carport PV system. System size is 108.0 kWdc and consists of (5) inverters, (360) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33277	18041-10000-28489	6259 W 87TH ST	90045	11	096B165   718	4123003027	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	11/20/2023 12:00:00 AM	ADDRESS	33.95867	-118.39463	PC FOR POWER AND ENRGY FOR CORE AND SHELL WORK TO  EXISTING SPACE, CHANGE OF USE FROM PRODUCE MARKET/RETAIL TO RESTAURANT AND BOOK STORE. SCOPE INCLUDES NEW SERVICE RATED AT 800A 3 PHASE 4 WIRE, NEW PANELS, EQUIPMENT CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 7000 SQ.FT  INDOOR AND OUTDOOR. B#17016-10000-34177	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33278	18041-10000-44605	5120 E YORK BLVD	90042	14	156A225   362	5478006010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.12079	-118.20403	TITLE 24 ONLY FOR COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33279	13041-20000-24578	6851 N LAUREL CANYON BLVD	91605	2	183B165   490	2321026040	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			09/09/2013 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.19528	-118.39677	new construction of 11 unit apartment. pc for power and energy. new house meter. 800a service. low rise residential.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33280	14041-20001-35054	12726 W FILMORE ST	91331	7	213B161   571	2532004002	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	01/26/2015 12:00:00 AM	ADDRESS	34.27997	-118.40996	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(18) SUNPOWER 327W MODULES(1) AURORA PVI-6000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33281	18041-30000-13373	9940 N COMANCHE AVE	91311	12	201B113    19	2741012011	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.25133	-118.57218	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (27) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33282	16041-10000-35963	10721 W STRADELLA CT	90077	5	144B149    78	4370006031	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.09326	-118.45398	New 1-story detached Accessory Living Quarter, building 2 of 3. Main building under 16041-10000-35957Plan check onlyNote: Electrical permit is cover under: 16010-30000-01647	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33283	10041-10000-11506	5250 N LANKERSHIM BLVD 4TH FLOOR	91601	4	171B173   367	2350018086		Central				1253.20	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.16668	-118.37545	TI IN AN EXISTING OFFICE AREA ON THE 4TH FLOOR. PLAN CHECK IS FOR POWER AND ENERGY. Permit is for additional panels, devices & circuits.  Variance filed to separate the Fire Life Safety System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33284	14041-10000-05702	1412 N CAMPUS ROAD	90042	14	156A223   137	5476019017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1834.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Expired	07/18/2016 12:00:00 AM	ADDRESS	34.12274	-118.21064	PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(10) MODULES: TRINA SOLAR TSM-250PA05.18(1)TRANSFORMERLESS INVERTER:  SOLAREDGE SE3000A-US-ZB-U.Inspector to verify if battens adequate physical protection.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33285	12041-20000-16149	9045 N LINCOLN BLVD 2nd floor	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	PIN	33.95655448	-118.41672503	T-24 lighting plan check for a portion of the second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33286	14041-20001-04980	16844 W FLANDERS ST	91344	12	213B133   614	2610005018	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.27997	-118.49947	(((expedite fees)))pv1 single family dwelling. total system size 6kw ac using transformerless inverter nonstandard plan. using power optiomizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33287	13041-10001-03377	555 S FLOWER ST FLR 51	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	permit to be pulled at EPC counter only. PC FOR ENERGY ONLYCHANGES TO APPROVED SET OF PLANS. ADDITION OF LIGHTS L12/13/14/15, and D11A/11b/12/23, M01, and T01. (lighting changed: LED south of elevators and track north of flexible meeting room and lights to ballroom perimeter.)CRA cleared on original application. TI  ON  51ST FLOOR AND ADDITION OF MEZZ AND KITCHEN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33288	12041-10000-27463	500 W WORLD WAY T5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	New fire alarm system for terminal 5 of LAX.( landside redevelopment)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33289	16041-10000-28704	950 W 81ST ST	90044	8	099B197  1056	6032005014	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	33.96534	-118.29076	PV1. New solar PV system for an existing residential roof-top. Total system size: 1.72kWac  and 8 microinverters and  8 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33290	18041-20001-00924	2440 S STONER AVE	90064	11	123B149   906	4260031016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.03026	-118.44578	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (1) inverter and (16) module. System is interconnecting with a 400 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33291	18041-10000-42011	6245 W WILSHIRE BLVD 103	90048	5	135B177   481	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.06356	-118.36478	Full plan check for first time restaurant tenant T.I located on the ground floor of a high rise building. Scope include new lighting and equipment with a total area of 1340-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33292	10041-10000-14652	2121 S AVENUE OF THE STARS 4th fl	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	12/13/2010 12:00:00 AM	ADDRESS	34.05554	-118.41342	remodeling offices in a highrise buildingplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33293	11041-10000-02957	1132 N VERMONT AVE	90029	13	144B197   506	5542029039	C2-1D, C2-2, P-1	Central	Hollywood	East Hollywood	YES	1913.01	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Issued	08/04/2011 12:00:00 AM	ADDRESS	34.09184	-118.29154	SERVICE UPGRADE TO 1200AMP & ADD NEW LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33294	12041-20000-23764	1601 N CAHUENGA BLVD	90028	13	148-5A187 317	5546007014	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.09987	-118.32967	Replace fire alarm system in club.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33295	14041-10001-06730	123 S HOBART BLVD	90004	10	138B193  1043	5517012030	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.07303	-118.30563	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(15) MODULES: CANADIAN SOLAR CS6P-250PX}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33296	10041-20000-02884	3800 W WILSHIRE BLVD 1st fl.	90010	10	132B193  1202	5093005***	C2-2, R4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	04/27/2010 12:00:00 AM	ADDRESS	34.06139	-118.30931	bank remodelEnergyEmergency lighting is existing.Request for Modification to separate Fire Alarm system filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33297	16041-20001-05440	18420 W HART ST	91335	3	183B125  1071	2125011020	M1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM			PC Approved	04/22/2016 12:00:00 AM	ADDRESS	34.19737	-118.53366	04/22/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. Changes have been made to the lighting floor plan.*****Previous Work Description*****PC FOR ASSEMBLY OCCUPANCY. RENOVATION OF HEALTH CLUB. PC FOR POWER AND ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33298	14041-20000-10159	5417 N ENCINO AVE	91316	5	174B129  1000	2257003010	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.16951	-118.51631	PV1.  Install 9 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33299	16041-10000-01972	700 S FLOWER ST suite 640	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	Tenant improvement:  3,741 SQ. FT. install new lightings and controlled receptacles. PC for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33300	19041-10000-07205	6350 W 3RD ST	90036	4	138B177   796	5509018009	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.07119	-118.36054	"INTERIOR REMODEL IN THE NORTH WEST CORNER OF AN EXISTING ""WHOLE-FOOD"" STORE, CREATING A BOOTH FOR ""AMAZON"" STORE. INSTALLING LIGHTS. T-24 ONLY. Emergency Lights and most of the Lights for the common areas are existing to remain.Building Permit: 19016-10000-04965"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33301	16041-20001-02256	8433 N WILBUR AVE	91324	12	192B121   411	2784009013	RA-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.22365	-118.54506	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33302	16041-10000-34214	2000 S AVENUE OF THE STARS 7TH FLR	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.05868	-118.41546	T-24, PC FOR ENERGY ONLY. INTERIOR TENANT IMPROVEMENT TO (E) OFFICE SPACE, INCLUDING. SCOPE INCLUDES NEW CONTROLS FOR EXISTING LIGHTS IN AN OFFICE SPACE ON THE 7TH FLOOR. TOTAL AFFECTED AREA IS 2838 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33303	17041-10001-28131	12250 W VENTURA BLVD	91604	2	162B165   241	2369004025	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	34.14289	-118.4003	Supplemental pan check per inspector's request (handwritten corrections on sheet E4) to show new receptacles and its homerun. SOW is noted as Delta-1.  Supplemental permit shall be issued for (4) new circuits<<PC FOR Fire damage repair of portion of mezzanine and roof framing AND Upgrade (e) bathroom for TITLE-24 ENERGY ONLY. TOTAL AFFECTED AREA 4815 SQ.FT. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS.B# 17016-30000-19689>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33304	18041-20000-06012	4141 W SANTA MONICA BLVD	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes a new service, new distribution equipment, lighting, and new loads throughout.Note: Building application has been generated under 17016-10000-17688	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33305	12041-20000-01963	260 S LA BREA AVE	90036	5	135B181   125	5513023006	C2-1LD, [Q]C2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	34.06965	-118.34383	ralph grocery store remodel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33306	15041-10001-22479	140 E 53RD ST	90011	9	108B205   365	5101012004	R2-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	33.99412	-118.27245	PV1.  Install 3.27 kW DC roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33307	12041-10000-05297	662 N SEPULVEDA BLVD	90049	5	138B145    76	4368016068	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.07736	-118.4688	New fire alarm system for an existing commercial space with 105 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33308	12041-10000-22165	2900 S SEPULVEDA BLVD	90064	5	120B157    63	4251003036	(T)(Q)RAS4-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Public Safety Only			09/18/2012 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.02876	-118.42927	NEW FIRE WARNING SYSTEM FOR A 48 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33309	16041-20001-03285	5400 N BALBOA BLVD #126	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Approved	06/09/2016 12:00:00 AM	PIN	34.16914714	-118.50029545	06-09-16 Changes to approved set of plans. Changes include increase square footage to 1519 sq ft,  replace existing lighting fixture to new LED lighting fixtures. Changes apply to delta 4 only. {{{{{Plan check for power and energy. Project site is an existing commercial building; tenant is a medical office.  Project scope is a tenant improvement. Work is being done within exam rooms. Total lighting area = 542 sq. ft.Note: Building application has been created under}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33310	16041-10000-28286	1232 W 186TH ST	90248	15	060B197   266	6109011019	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	33.86188	-118.2955	PV1. Plan check for PV roof mounted system. System size: 5.0kWac with 18 modules kyocera and 1 inverter ABB PVI-5000-OUTD-US-A-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33311	14041-20000-01483	14714 W ORACLE PL	90272	11	132B129    53	4422032008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.05537	-118.51911	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.8KW AC USING 2 TRANSFORMERLESS INVERTTERS NONSTANDARD PLAN. TOTAL OF 40 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33312	19041-10000-33005	7025 S MAIN ST 1-11	90003	9	102B201   656	6012010034	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.10	Electrical	Electrical	Apartment			08/22/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	04/28/2022 12:00:00 AM	ADDRESS	33.97582	-118.27416	FULL PLAN CHECK FOR A NEW 3 STORY 11 UNIT APARTMENT BUILDING WITH  GARAGE AT THE 1ST LEVEL. SERVICE SIZE IS 600A. TOTAL AFFECTED AREA  IS 7,882 SQ.FT  FIRE ALARM VARIENCE SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33313	16041-30000-23036	3327 S SEPULVEDA BLVD	90034	5	120B157   867	4251015903	OS-1XL	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.02154	-118.42446	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 3202.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33314	14041-20000-17420	10110 N WEALTHA AVE	91352	7	204B173   252	2528017009	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.25401	-118.37528	6KW Standard PV1 roof-mounted system with (24) Enphase M215 microinverters and Solarworld Sunmodule SW250 Poly modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33315	16041-20000-22609	8100 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	33.95164	-118.43579	Plan check for energy.  TI to currency exchange store.  263 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33316	17041-20000-45995	1753 S VIRGINIA ROAD	90019	10	126B185   644	5071007062	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.04192	-118.33418	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 18.72KWNote: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33317	17041-20000-29152	7243 N CEDAR ROAD	91405	2	186B153   937	2217032106	(T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.20259	-118.44077	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 3 kWac and consists of (1) inverter, (6) modules, (1) 5 kWac Powerwall, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33318	16041-20002-30704	445 S ARDMORE AVE 1-129	90020	10	135B193   591	5503009016	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			06/05/2017 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.06592	-118.30178	[[[[6/5/17 CHANGES TO APPORVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ONLY. CHANGING TO LINE SIDE TAP ]]]]Plan check for a PV2 roof-mounted PV system. System size is 40 kWac and consists of (4) inverters, (176) modules, and (1) load center.Note: $0.00 permit fee due to Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33319	11041-10000-15208	15 E HORIZON AVE 1-20	90291	11	108A143   410	4226006006	RD1.5-1	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Apartment			07/20/2011 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Closed	07/25/2011 12:00:00 AM	ADDRESS	33.98837	-118.47425	REMOVE AND REPLACE THE EXISTING FIRE ALARM WITH COMPATIBLE PANEL WITH ADDED DIALER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33320	18041-20000-21379	375 S COLUMBIA AVE	90017	1	132A207    44	5153019020	R4-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.05754	-118.26579	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33321	15041-10000-25582	333 S GRAND AVE 12th floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM			PC Approved	08/07/2015 12:00:00 AM	ADDRESS	34.05271	-118.25179	TI to (E) 18,079 sq ft. commercial office space in an (E) highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33322	15041-10000-18179	10201 W PICO BLVD BLD-95	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Issued	06/11/2015 12:00:00 AM	PIN	34.05182951	-118.41257696	INSTALATION OF NEW FA SYSTEM FOR A UTILITY BUILDING. 35 FA DEVICE  AND ONE PANEL. PERMIT ISSUED AS OWNER -BUILDER  TO LADBS-ISSUED ELECTRICAL MAINTANANCE SUPERVISOR LIC3ENCE # 966291(EXPIRATION DATE 10/31/15).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33323	15041-10002-25634	731 S BROADWAY	90014	14	127-5A209  68	5144014032	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.04456	-118.25423	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE ADDITION OF A ROOF DECK AND NEW PANEL. ((((((((((((PC for power and energy. Scope includes new 800A 120/240V 3ph-4w service and distribution system for (E) 4-story commercial building. Total affected area is 19295 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33324	17041-10000-08622	13500 W HUBBARD ST	91342	7	225B157   825	2512001078	C4-1-K-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.30982	-118.42736	PC for energy only, outdoor. Removing HID fixtures and replacing them with new LED ones. Area: 17,725.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33325	13041-10000-02087	1122 E 12TH ST	90021	14	123A213   205	5132016045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.0308	-118.24708	600A NEW SERVICE FOR SINGLE STORY BUILDING REMODEL.  6 TENANTS FOR RETAIL SPACE.  POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33326	19041-20000-32434	12437 W RYE ST	91604	2	165B165   176	2364016020	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.1514	-118.40445	Install 13.5 kWh energy storage system and associated distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33327	11041-10000-15142	8500 W BEVERLY BLVD # 736C	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT IN REMOTE STORAGE SPACEPLAN CHK IS FOR TITLE 24; PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33328	10041-10000-12250	6280 W HOLLYWOOD BLVD	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.10146	-118.32615	Ti for a new restaurant. Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33329	13041-10000-07988	4464 N VAN NUYS BLVD	91403	4	168A151   276	2265014001	C4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.15276	-118.44848	Permit to be pulled at electrical plan check counter.T24 for outdoor lighting outside of a Citibank.   1,458 sq ft hardscape area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33330	13041-10000-09263	5228 N CAMPO ROAD	91364	3	171B105   695	2168004040	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.164	-118.59807	PV1 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 13.08 KW. 40 MODULES AND 1 INVERTER. [INVERTER: SUNPOWER SPR-11401F-1 UNI] [MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33331	13041-10000-02536	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	TI OF DODGER STADIUM LEVEL 4 RETAIL SPACE. NEW CONNECTED LOAD > 400A. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33332	13041-10001-27554	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			Reviewed by Supervisor	07/20/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLANS ARE AS-BUILT SET; FIELD CHANGES INCLUDE THE OUTLAY OF THE SWITCHBOARDS;CHANGES ARE CLOUDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33333	11041-20000-03768	5461 N LOUISE AVE BLDG B	91316	5	174B133   709	2257011006	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	07/18/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.17055	-118.50999	"PLAN CHECK POWER FOR NEW TWO STORY SCHOOL BUILDING (BLDG.""B"") PRIVATE SCHOOL CAMPUS. EXISTING SERVICE SUPPLYING NEW BUILDING."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33334	17041-10000-11327	5419 S MCCONNELL AVE	90066	11	102B157    40	4211009012	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	33.97821	-118.42002	PC for a new(A-1 OCCUPANCY LOWRISE BUILDING) fire alarm installation. New fire alarm panel, and 68 Fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33335	17041-20000-13476	3833 S DUNN DR 1-40	90232	5	120B165  1292	4207005036	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			04/25/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.02201	-118.39919	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP, 2 RPS AND 128 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33336	14041-20000-32458	5627 N ALLOTT AVE	91401	2	174B157   489	2343011013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.17292	-118.42811	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2 KW INTERCONNECTED WITH MAIN SERVICE PANNEL. (38) SUNPOWER 327W MODULE(2) POWERONE PVI INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33337	19041-10000-23551	3800 S WESTERN AVE	90062	8	117B193   782	5036008006	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.01723	-118.30873	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33338	17041-10000-25473	842 E JEFFERSON BLVD	90011	9	117A207   294	5121003011	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.01391	-118.26221	PLAN CHECK FOR T24 ONLY - SCOPE INCLUDES REPLACING EXISTING (12) HID FIXTURES WITH NEW LED FIXTURES - TOTAL AFFECTED AREA = 6860 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33339	16041-10000-08769	220 S HOOVER ST	90004	13	136-5A201  49	5155007010	RD1.5-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.06993	-118.28419	PV2 rooftop solar on a triplex unit.   (30) SW 260   (1) FRONIUS 7.6 PRIMO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33340	10041-20000-11525	11150 W SANTA MONICA BLVD SUITE-1020	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	lighting and receptacles in unit 1020. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33341	18041-10000-30346	19701 S HAMILTON AVE	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	33.85221	-118.28625	TENANT IMPROVEMENT WORK ON +/- 3,465 SQ. FT. OF THE TOTAL FLOOR AREA. THIS IS PLAN CHECK FOR T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33342	12041-20000-29372	8987 N LAUREL CANYON BLVD	91352	6	195B165   219	2629019012	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.2326	-118.40475	Tenant improvement to an existing Medical Clinic.  Full Plan Check.  VERIFY IF NEEDED TO CHECK OSHPD III.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33343	10041-20000-24396	6100 N SEPULVEDA BLVD	91411	6	177B145   597	2242025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	07/19/2011 12:00:00 AM	ADDRESS	34.18076	-118.46437	EMPLOYEE BREAK ROOM AT COSTCO ENERGY PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33344	13041-20000-11124	4922 N ANDASOL AVE	91316	5	168B133   113	2290001004	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.15967	-118.51136	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. 49 PANELS AND 2 INVERTERS. TOTAL SYSTEM SIZE: 12KW. [INVERTER: FRONIUS 5.0-1 UNI AND 6.0-1 UNI] [SOLAR MODULE: REC245PEBLK]. USING 125A PV PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33345	17041-10000-23768	14900 W SHERMAN WAY	91405	6	183B149    80	2220005027	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.20096	-118.45772	Plan check for T24 only to change (20) existing fixtures with new LED fixtures. Total affected area 10750 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33346	15041-20001-41345	600 WORLD WAY TERM. 6-655	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	04/28/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4. Changes have been made to the lighting floor plan, the power floor plan, and the transformer has been relocated.*****Previous Work Description*****T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (TERMINAL RESTUARANT/CAFE ON TERMINAL 6 UNIT 655 FB). SCOPE INCLUDES NEW LIGHTING AND PANELS. TOTAL AREA IS 2547 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33347	12041-20004-01606	1413 E 20TH ST	90011	9	120A211   351	5129005011	[Q]CM-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.02162	-118.24853	T24 and emergency lighting plan check only for new one story warehouse building. Service is only 400 amperes.  Original submittal to building plan check is  100' X 160' 1 STORY TYPE III-B SPRINKLERED WAREHOUSE W/ 35' X 75' MEZZANINE AND ROOF TOP PARKING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33348	15041-10000-40553	1515 S WESTGATE AVE (1-19)	90025	11	126B145   506	4263033067	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.04163	-118.45883	New fire alarm system for a 4-story 19-units apartment building; Scope includes (1) fire alarm system, (1) control panel, (2) communication panels and (71) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33349	11041-10000-00464	2222 S FIGUEROA ST	90007	9	123A205   107	5126006018	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.031	-118.27396	CONVERT RETAIL SPACES TO LIVE/WORK UNDER ADAPTIVE REUSE  - 11 UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33350	19041-20000-07545	7968 S MCCONNELL AVE	90045	11	099B161   560	4112009001	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	33.9662	-118.41265	PLAN CHECK FOR NEW PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 5.94 KW DC/6 KW AC. SCOPE OF WORK INCLUDES (18) PANASONIC VBHN330SA16 PV MODULES, (1) NEW 125A PV LOAD CENTER, AND (1) SE6000H-US INVERTER. MAIN BREAKER DERATED TO 175A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33351	16041-10000-37286	709 E 53RD ST	90011	9	108B205   308	5103006011	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.99426	-118.2627	roof mountedPC FOR PV SYSTEM. TOTAL OF 3KW AC USING CENTRAL INVERTER SYSTEM WITH 8 SOLAR MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33352	19041-10000-41832	12403 W ADDISON ST	91607	2	171B165  1035	2356024044	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Issued	10/15/2019 12:00:00 AM	ADDRESS	34.16108	-118.40326	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 31 MODULES (Q-CELL 285) , 31 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE7600H-US).  SYSTEM SIZE IS 8.84KWdc and 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33353	18041-10000-13170	520 E TEMPLE ST	90012	9	130-5A215 309	5173009902	[T][Q]C2-2D	Central	Central City North	Historic Cultural		2060.30	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.05021	-118.23478	REPLACEMENT OF EXISTING FIRE ALARM PANELS AND INSTALLING NEW DEVICES IN AN EXISTING BUILDING.1 FACP, 3 RPS AND 112 NEW DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33354	17041-10003-32818	7348 N ETHEL AVE Units A&B	91605	2	186B161   541	2327015007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/18/2019 12:00:00 AM	PIN	34.20432132	-118.41768776	FULL PLAN CHECK FOR A LOST, PREVIOUSY APPROVED PLANS. Last supplimental plans are attached for reference. Master application number:  17041-20000-28729Note: Building application has been generated under 16014-20000-04290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33355	19041-20000-02187	11427 W DONA PEGITA DR	91604	2	159B169   467	2380017010	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.13135	-118.37948	Plan check for a PV1 roof-mounted PV system. System size is 3.35 kWdc/2.847 kWac-CEC and consists of (10) modules and (10) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33356	13041-10000-16367	2215 S BUDLONG AVE	90007	8	123B197   260	5054018004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.03583	-118.29663	PV1.  Install 10.78 kW DC roof-mounted solar array, interconnect with main service panel.  negative grounded {44 modules: Trina Solar TSM245} {1 FRONIUS IG PLUS V 7.5-1UNI}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33357	19041-20001-34222	2446 N WILD OAK DR	90068	4	153B193   136	5580027026	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			Reviewed by Supervisor	09/18/2019 12:00:00 AM	ADDRESS	34.11509	-118.31032	Expedited plan check fee.PV1.  Install 12.285 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (39) modules with 11.4 kW rated inverter; (2) 13.5 kWh energy storage units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33358	16041-20001-23116	11711 W PICO BLVD	90064	11	123B149   653	4260029033	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM			PC Approved	01/13/2017 12:00:00 AM	ADDRESS	34.03159	-118.44613	01/06/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from dry cleaning to office/tenant improvement. Total lighting area = 882 sq. ft.Note: Building permit has been pulled under 15016-10001-22029*****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF ART STUDIO. 958 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33359	13041-20000-34707	3021 N VERDUGO ROAD	90065	1	150B213   640	5457009021	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	PIN	34.10599072	-118.23799242	PC FOR ELECTRICAL SYSTEM ONLY. NEW 600A SERVICE FOR EXISTING FIRE DAMAGED. REPLACE LIKE FOR LIKE. NEW SUBPANELS FOR RELICATION. NO CHANGE IN LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33360	15041-10000-04316	11862 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.28593	-118.50158	Plan check for Title 24 only. Project site is an existing building (gym). Total lighting area = 595 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33361	13041-20000-29217	11052 N BAIRD AVE	91326	12	210B125   433	2717014023	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.27129	-118.53704	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.9 KW AC USING 32 MODULES. USING ENPHASE MICROINVERTER. USING STANDARD PLAN. ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33362	16041-10001-06474	300 S SANTA FE AVE SPACE B	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	06/30/2016Changes to an approved set of plans, Changes include a change of fixstures and revisions to the T-24 calculations. Permit was pulled under the master application. (((PC FOR POWER AND ENERGY. 6 STORY BUILDING. 1ST TIME TENANT BOOKSTORE RETAIL IN SPACE B, GROUND LEVEL. TOTAL AREA 2289 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33363	15041-10000-02218	2716 1/2 W COUNCIL ST	90026	13	138A203   378	5156021005	RD1.5-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.07149	-118.27738	PV1.  Install 4.08 kW roof-mounted, utility-interactive ungrounded PV system.  Unable to submit application online due to connection to (E) distribution panel (not service panel).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33364	16041-20001-35623	12537 N KENNY DR	91344	12	219B137    46	2609021011	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	34.29808	-118.49847	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.3 kWac and consists of (57) modules, (57) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33365	13041-10000-36167	1015 S SAN JULIAN ST	90015	14	124-5A211  51	5145019014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.0366	-118.25276	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33366	18041-20000-22039	8087 W WILLOW GLEN ROAD	90046	4	153B173   162	5565025005	RE11-1-HCR	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.1176	-118.37248	PV1.  Install 11.55 kW DC roof mounted grid tied PV system and 27 kWh energy storage system.  (33) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33367	12041-20000-13642	4440 N VANTAGE AVE 1-30	91604	2	165B165   200	2364002051	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			06/12/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.15143	-118.39737	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33368	10041-10000-11554	1 S LMU DR chapel-building	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	09/02/2010 12:00:00 AM	ADDRESS	33.96577	-118.42406	T-24 and emergency lighting in remodel of office area in basement of  chapel building.  Inspector, please verify that all occupancy sensors are multilevel type as required for the power adjustment factor in table 146-C, and as claimed on form LTG-2C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33369	13041-10001-30820	3430 S VETERAN AVE	90034	5	120B161  1003	4254021021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.02302	-118.41839	Expedited RSES plan check per applicant request.PV1, Install 5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 20 modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33370	16041-20000-10797	840 W 41ST ST	90037	9	114B197   480	5019003027	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.00905	-118.28869	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33371	13041-10000-33765	6220 S VERMONT AVE	90044	9	105B197   993	6004014029	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	33.98299	-118.29128	TITLE 24 PART 6 ENERGY FOR EXISTING SINGLE STORY BUILDING. SCOPE OF WORK < 400A. LIGHTING RENOVATION IS FOR INDOOR TO AN 1664 SQ FT AREA. ADDING 3 NEW FIXTURES. NOTE: CIVIL ENGINEER WILL PERFORM ALL TRAITS, INCLUDING BUILDING, MECHANICAL, AND ELECTRICAL, PER APPLICANT & BUILDING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33372	15041-10000-19133	5909 S WALL ST	90003	9	105B205   148	6006002040	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	33.98708	-118.27191	PV1, ROOFTOP MTD., 16 MODULES, 1 INVERTER, 3.0 KW AC. XFORMERLESS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33373	11041-10000-17126	5791 W RODEO ROAD	90016	10	120B173   510	5047002057	[Q]C4-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/12/2011 12:00:00 AM	ADDRESS	34.02186	-118.37175	TI FOR AN EXISTING 7-ELEVEN. PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33374	15041-20000-31731	17915 W BURTON ST	91335	12	192B129   415	2101019017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.22015	-118.52343	Plan check for a PV1 roof-mounted PV system. A new system is being added to an existing system. New system size is 3 kWac. Total system size is 6.8 kWac. New system consists of (1) inverter, (15) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33375	18041-10000-44976	533 W VERNON AVE	90037	9	112-5A201  27	5019010006	[Q]C2-1VL	South Los Angeles	South Los Angeles			2317.20	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.00388	-118.2839	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33376	16041-10000-37768	500 E WATER ST PV	90744	15	027B209   227	7440010910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Issued	01/10/2017 12:00:00 AM	ADDRESS	33.76653	-118.25893	Permit fee is $0.00 due to Senate Bill 1222.PC FOR PV SYSTEM FEED IN TARRIF (FIT), Roof mounted PV system. SYSTEM SIZE IS 1085KW.DC APPROX. 860KW.ACSYSTEM INCLUDE 3192 MODULES AND 11 INVERTERS (50KVA)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33377	18041-20004-34502	10419 W DUNLEER DR	90064	5	123B161    22	4318021023	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.03702	-118.41235	11-30-2018 Changes to an approved set of plan, Changes include PV modules roof layout. Changes has been clouded.Plan check only.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33378	14041-20001-30983	11835 W BLYTHE ST	91605	6	189B169   284	2310022019	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	34.21492	-118.39111	Revision to an approved set of plans. Relocation of inverter. From north wall to east wall.Roof mounted PV system with transformerless inverter. Total system size is 3.9KW.Note: The solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33379	14041-10000-16815	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.06371	-118.3703	TITLE-24 PLAN CHECK ONLY.  TOTAL AREA = 4,335 SQ. FT.TI FOR EXISTING COMMERCIAL SPACE IN A HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33380	19041-20001-30978	14842 W LEMAY ST	91405	6	180B149   280	2236005013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	34.19186	-118.45667	Revision to approved set.  Removal of separate AC disconnects from energy storage system.(((Plan check for energy storage system, Energy storage size: 27KWh. 2 Tesla Power Wall2.0)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33381	12041-20000-25859	12776 W FOOTHILL BLVD	91340	7	216B161    44	2514007043	[Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	PIN	34.29079383	-118.41362215	New compressed natural gas fueling station.  New 1600 amp service, panels, equipment, and outdoor lighting.  Area is classified hazardous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33382	13041-10000-36257	8640 W WENTWORTH ST	91040	7	207B189   184	2555002055	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	34.26681	-118.3214	PV1, Install 4 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (16) Modules: Trina Solar TSM-250PA05.18.(16) Optimizers: Solaredge OP250-LV-AH4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33383	13041-10000-27934	600 W 7TH ST	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.04728	-118.25685	TITLE 24 ENERGY PLAN CHECK ONLY. 776 SQFT, EMERGENCY LIGHTING. HIGH RISE. REPLACING FIXTURES AT THE AREA BETWEEN ELEVATORS. PERMIT PREVIOUSLY PULLED UNDER EXPRESS PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33384	19041-10000-11707	121 E 6TH ST 1-103	90014	14	127-5A211 352	5148020012	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM			PC Approved	04/19/2019 12:00:00 AM	ADDRESS	34.04493	-118.24918	Full PC for a parking area being converted to a lounge area, place of assembly. Total square footage is 5475. Scope of work includes installing a new 225 A panelboard and associated equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33385	14041-10000-20007	756 S SPRING ST 759 Main	90014	14	127-5A211 345	5144015228	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.04308	-118.25343	Additional fees must be paid at time of re-submittal for first-time tennant full plan check.Title 24 plan check only.  Total area = 1,446 sq. ft.TI to existing retail space including lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33386	15041-20001-02048	7251 N BALBOA BLVD	91406	6	186B133  1083	2227003***	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.20273	-118.50132	EXPEDITE PER APPLICANT REQUEST[PV2Install a roof-mounted solar array on a 4-unit condo. Interconnect with individual unit panel, backfeed to 225A shared service.System size: 6kW. Ungrounded system.25 255kW pv modules across 3 strings (7 and 9+9 combined).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33387	11041-20000-19808	16869 W ENCINO HILLS DR	91436	5	162B133   234	2287002012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2011 12:00:00 AM			Corrections Issued	09/24/2011 12:00:00 AM	ADDRESS	34.13855	-118.50153	Plan check for new roof mounted 11.18KW photovoltaic system for single family. Including upgrading service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33388	13041-20001-30942	811 W WILSHIRE BLVD Suite 1460	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM			Corrections Issued	11/25/2013 12:00:00 AM	ADDRESS	34.04973	-118.2584	((11/25/2013- REMOVED LUMINAIRE TYPE '5' AND REPLACED IT WITH RECESSED LED LUMINAIRES))T24 FOR EXISTING HIGHRISE OFFICE. SCOPE OF WORK ON 1460 [14TH FLOOR]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33389	17041-20000-28082	14923 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29453	-118.45606	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33390	15041-10001-37113	22635 W CANTARA ST	91304	12	189B097    79	2013006018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM			PC Approved	11/25/2015 12:00:00 AM	ADDRESS	34.21784	-118.62027	Expedite per applicant request.Install a roof mounted solar array on a SFD. Interconnect with 200A MSP w/ a 175A main.System size: 10.2kW (6+4.2). Ungrounded system. (35) 327W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33391	19041-20000-44154	1262 E PALMETTO ST	90013	14	126A217    44	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	09/04/2020 12:00:00 AM		Permit Finaled	10/06/2020 12:00:00 AM	ADDRESS	34.04005	-118.23347	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33392	14041-20000-29158	6320 N NEWCASTLE AVE	91316	5	177B125  1030	2123022069	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	PIN	34.18458062	-118.52508192	PV1CENTRAL STRING INVERTER STANDARD PLAN SIZED 6.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33393	19041-20000-29608	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to create a new corridor on the 1st floor. Total lighting area = 1,328 sq. ft.Note: Building application has been generated under 18016-20000-08107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33394	19041-10000-06985	1475 S ROBERTSON BLVD	90035	5	129B169   274	4305014078	C2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.05254	-118.3842	"POWER AND ENERGY PC FOR A TI FOR A CHANGE OF USE FROM ""M"" RETAIL OCCUPANCYTO ""E"" PRIVATE PRE-SCHOOL. SCOPE INCLUDES NEW 600 SERVICE, RECEPTACLES, LIGHTING AND EQUIPMENT. TOTAL AFFECTED AREA IS 10,586 SQ.FTB# 19016-10000-054355/16/19: Modification for 30Day meter reading is filed"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33395	19041-10000-11850	1040 N LAS PALMAS AVE STAGE 6	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33396	14041-10000-34907	105 S MARIPOSA AVE	90004	13	138B197   935	5518006004	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Apartment			12/17/2014 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.07254	-118.2996	NEW 40-UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33397	15041-10001-07190	1070 N SOMERA ROAD	90077	5	144B149   166	4369032017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM	ADDRESS	34.09151	-118.45886	EXPARDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33398	10041-20000-14353	1680 N VINE ST	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	10/08/2010 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check power for service upgrade to 4000A 120/208V service (Taft Building). Connected loads are future. Disconnect existing 120/240V service and refeed existing panels and circuits to new 1200A 120/208V section. Building has existing 1 service for fire pump. Future tenants shall require full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33399	15041-30000-38141	517 W WASHINGTON BLVD	90291	11	105A147    72	4228015045	(Q)C4-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	PIN	33.98308219	-118.46082997	Title 24 plan check only.  Total area = 928 sq. ft.     Remodel of existing restaraunt.  New lighting and cooking equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33400	12041-10000-24914	1356 E PALMETTO ST	90013	14	126A217    47	5164006011	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.04017	-118.23089	TI IN AN EXISTING RESTUARANT.  T-24 ENERGY CALCS FOR THE LIGHTS IN THE RESTROOMS AND THE EMPLOYEES DRESSING ROOMS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33401	16041-20001-09619	1715 S ORCHARD AVE	90006	1	126B197   336	5056019036	R3-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.04282	-118.28878	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 2.3 kWac and consists of (9) micro-inverters and (9) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33402	15041-10000-00895	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"Plan check for T-24 only. Replace existing fluorescent light sign to LED. Retrofit existing fluorescent light sign to LED. sing with with new face Panel. Added new LED sign connect to existing power circuit. Refference Building permit: 14048-10000-02681PROPOSED 4'-6"" X 5'-6"" X 6'-5"" HIGH D/F ILLUM. INFO. SIGN (4-4)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33403	15041-20000-18282	16450 W FOOTHILL BLVD	91342	7	228B137   183	2603007036	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.31882	-118.48831	Service upgrade to 2000A in existing commercial building.  Consolidating 3 meters into 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33404	18041-10001-45927	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	EXPEDITED PER APPLICANT REQUEST. ((((PV3. DC BUILDING INTEGRATED PV SYSTEM ON A NEW COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 30.0KWac.(313)MODULES-WW-100 PV MODULES(3)INVERTERS-SOLAREDGE SE10KUS(123)OPTIMIZERS-SOLAREDGE P400PC ONLY, PERMIT UNDER PCIS#18041-10000-45927	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33405	14041-20000-02621	10923 W RANDALL ST	91352	6	198B173    51	2408001022	(Q)M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/29/2014 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.23908	-118.36897	pc for new 800A service upgrade. new pull section and distribution board. all loads existing. no new loads at this time.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33406	10041-20000-12682	805 W MANCHESTER AVE	90044	8	097-5A199 203	6032014023	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	11/17/2010 12:00:00 AM	ADDRESS	33.96022	-118.28728	new 600a service to replace existing 400 A at Jack in the Box	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33407	16041-20001-38503	17548 W SAN FERNANDO MISSION BLVD	91344	12	210B129   360	2712004021	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.27194	-118.51701	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of pv system, roof-mounted on SFD. Interconnect with a 200A MSP.13.44kW ungrounded system. (56) EnPhase M250 microinverters. (56) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33408	13041-10000-32978	2080 N HILLHURST AVE	90027	4	150B201   302	5590008036	[Q]C4-1	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Issued	11/25/2013 12:00:00 AM	ADDRESS	34.10975	-118.28727	PLAN CHECK FOR POWER. NEW 600A OVERHEAD SERVICE TO REPLACE INDIVIDUAL TENANT SERVICES AS ONE TENANT(MARKET) WILL TAKE ALL TENANT SPACES.THERE ARE NO CHANGES TO THE CONNECTED LOADS FOR THE MARKET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33409	13041-10008-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	"DELTA ""1"" CHANGES ON PAGES ""E1 & E001"" INSTALL A NEW 15KVA XFMR,  AND A NEW 50AMP PANEL (OUTDOOR NEMA 3R),  AND 10 NEW CIRCUITS. <<<<COMPLETE RENOVATION OF CLASSROOM BUILDING CONSISTING OF BASEMENT AND TWO STORIES ABOVE. INCLUDES NEW LIGHTING, RECEPTACLES, HVAC, PANELS, AND A NEW SERVICE. EXISTING AND NEW WORK IS DIVIDED BY A DASHED LINE ON SINGLE LINE DIAGRAM. APPLICANT BROUGHT PRE-CUT CHECK, FEES TO BE RECALCULATED.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33410	14041-10000-35242	21727 W NORDHOFF ST #A	91311	12	198B105   230	2746012041	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.23562	-118.60323	Plan check for Title 24 only. Project scope is to remoce HID fixtures and replace with new LED fixtures. Total lighting area = 9332 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33411	14041-10000-26651	16542 W VENTURA BLVD	91436	5	168B137   369	2284005025	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Closed	06/19/2015 12:00:00 AM	ADDRESS	34.1576	-118.49393	Full plan check. Medical office. Building application number 14016-10000-19503. TI  to convert commercial office to medical space in existing 5 story building. Installing new lighting, power, and communication systems. Fire alarm to be submitted separately.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33412	15041-20000-21215	3754 N WHITESPEAK DR	91403	4	162A147   179	2278028006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.13766	-118.46287	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33413	15041-10000-12520	5802 W WILLOUGHBY AVE	90038	13	144B189  1034	5534029003	[Q]C2-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.08696	-118.32253	TI TO AN (E) BUILDING, OFFICE SPACE TO REMAIN.  TI-24, PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33414	16041-10000-41837	6238 N FULTON AVE	91401	2	177B157   256	2331002052	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.18419	-118.42235	Pc for power and energy. New 3-story 18-unit  apt building,. 1200A service . Total area 14292 sq ft. Non-Mehane zone with on grade parking. B# 14010-10000-00351Fire alarm has been filed seperately.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33415	18041-10000-32766	7856 W FOOTHILL BLVD	91040	7	204B193   177	2559010032	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.25946	-118.30465	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33416	17041-10000-04952	5715 S MESMER AVE	90230	11	105B165   407	4220014058	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	33.98459	-118.39992	T-24, PC FOR ENERGY ONLY. FULL FLOOR INTERIOR TI AT 1ST STORY, 2ND STORY, AND MEZZANINE LEVEL OF EXISTING OFFICE BUILDING. SCOPE INLCUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10347 SQ. FT. B#16016-10000-31030	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33417	15041-10000-36116	7326 N VANALDEN AVE	91335	3	186B121   819	2104026001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.20382	-118.54902	PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE: 9KW. (29) MODLUES AND (3) INVERTERS. (29) SUNPOWER SPR-327-NE-WHT-D(3) SMA AMERICA SB3000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33418	14041-20001-24673	19716 W TRAMMELL LANE	91311	12	210B117   402	2701054020	RE20-1-H-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2014 12:00:00 AM			PC Approved	10/02/2014 12:00:00 AM	ADDRESS	34.27191	-118.56333	Expedited plan check fee.  PV1.  Install 13.2 kW roof-mounted, utility-interactive PV system.  (2) 6 kW SolarEdge transformerless inverters with DC-DC converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33419	18041-20000-10175	13171 N DOSS CT	91344	12	225B133   212	2602001023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.30995	-118.5027	pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33420	15041-20001-18165	12905 W VENTURA BLVD	91604	2	165B161   996	2375022050	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM			PC Approved	03/22/2016 12:00:00 AM	ADDRESS	34.14536	-118.41396	03/22/2016 Changes to an approved set of plans. Changes have been made to the lighting and power floor plans. All changes have been reflected onto the Title 24 Compliance Forms. All changes have been clouded and marked as Delta 2 and 3.*****Previous Work Description*****TI to existing commercial building (restaurant). Plan check for power and energy. Adding new 600A service. Adding new lighting including emergency. Total sqft. 2,087.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33421	13041-10000-25423	3051 S DANALDA DR	90064	5	123B165   139	4316015015	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM			Reviewed by Supervisor	09/24/2013 12:00:00 AM	ADDRESS	34.03642	-118.40378	PV1.  Install 12.5 kW DC roof-mounted solar array, interconnect with main service panel.  Fronius IG PLUS V 10.0 transformered inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33422	17041-20000-42743	8815 N QUAKERTOWN AVE	91324	12	195B113   263	2782032013	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Issued	12/05/2017 12:00:00 AM	ADDRESS	34.23055	-118.56991	pv1install roof mounted pv system sized 6kw interconnected  with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33423	13041-20000-07662	4743 N TOPEKA DR PV-1	91356	3	168B121   333	2176031029	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.15577	-118.54763	PV-1. Plan check for one 2.5kW inverter, one 5kW inverter, one 7.5kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33424	15041-20000-42596	21218 W ROSCOE BLVD	91304	3	192B105   663	2109002031	M2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.21968	-118.5943	Plan check for power only. Project site is an existing commercial building (Home Depot). Project scope is the installation of (2) 400-amp panels and (16) HVAC units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33425	16041-10000-01189	4562 W ROSEWOOD AVE	90004	13	141B193  1442	5521024013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Expired	02/12/2018 12:00:00 AM	ADDRESS	34.07889	-118.30398	PV1, Install 2.385 kW DC roof-mounted solar array, interconnect with service panel. Transformerless. (1) Inverter. : ABB PVI-3.0-OUTD-S-US-Z-A. (9) Modules KYOCERA KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33426	12041-20000-30820	12030 W SHERMAN WAY	91605	2	183B165    91	2321003037	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM			PC Approved	02/08/2013 12:00:00 AM	ADDRESS	34.20028	-118.39552	energy plan check warehouse	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33427	14041-20000-15447	1661 W 240TH ST	90710	15	042B193   713	7439007***	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.80741	-118.3065	Tittle 24 plan check only for commercial building with 6442 square footage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33428	14041-10000-18671	670 N PERUGIA WAY	90077	5	141B149   162	4362003017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.08163	-118.45004	Install roof mounted solar PV system on existing residential building.  Total system size = 17.7 kW DC.  61 modules w/ central inverter. INVERTER: SOLECTRIA PVI 14TL -240V. MODULES: LG290N1C-A3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33429	19041-10000-04654	12645 W TIARA ST	91607	2	177B161   968	2341004016	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.17859	-118.4087	(Fee is $0 per AB1414). PLAN CHECK FOR 12.6KVA ROOF MOUNTED PV SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(SE7600H-US AND SE5000H-US) WITH 56 MODULES WITH P320 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33430	13041-10000-20961	1522 E 102ND ST	90002	15	091-5A213 174	6048012928	PF-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	33.94413	-118.24744	13041-10000-20961TITLE 24 PLAN CHECK ONLY. 1 STORY BUILDING. 6352 SQFT. EMERGENCY LIGHTING.  OFFICES. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33431	15041-10000-24624	725 S FIGUEROA ST 41st floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	Energy plan check for (2) restrooms located in an office of a high rise building. Total 518-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33432	17041-20000-22165	11926 W OXNARD ST	91606	2	177B165   766	2339003020	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.17926	-118.39314	Plan check for roof-mounted solar pv system with AC coupled battery backup system for SFD.3.8kW ungrounded system. (14) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33433	16041-20000-29562	2020 N CUMMINGS LANE	90027	4	151-5A195 197	5589009032	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	34.10784	-118.30112	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (36) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33434	14041-10000-12709	8515 N TELFAIR AVE	91352	6	192B169   350	2632023065	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Expired	06/07/2016 12:00:00 AM	ADDRESS	34.22411	-118.38403	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL  7525 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33435	17041-20001-22306	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	10/6/2017changes to an approved set of plans. changes include revisions to lighintg floor plan and energy calculations.  This is plan check only.  (((((ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for energy only.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33436	17041-20000-04192	9812 W VIDOR DR 1-8	90035	5	132A165   318	4330005***	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.05439	-118.40326	new fire alarm control panel reconnect existing devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33437	17041-10000-38817	13790 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.30953	-118.43339	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 42575 SQ. FT. TOTAL AFFECTED AREA IS 42575 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33438	17041-20000-35695	2275 N HIDALGO AVE	90039	13	147A209   201	5440006024	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Expired	09/17/2023 12:00:00 AM	PIN	34.09715131	-118.25719039	permit fee $0.00 by state senate bill no. 1222pv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33439	16041-20000-05631	865 S FIGUEROA ST SUITE 2309	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plancheck for T24 ENERGY ONLY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. 23RD FLOOR. SUITE 2309.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33440	18041-10000-44604	5343 W IMPERIAL HWY #800-850	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Issued	11/21/2018 12:00:00 AM	ADDRESS	33.93128	-118.37337	INSTALL LIGHTS IN A WALK-IN FREEZER IN SUTE# 800-850. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33441	12041-10000-28185	10100-10102 W EMPYREAN WAY Bldg # 7 &-# 8	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Apartment			11/26/2012 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.05388	-118.40887	REPLACING EXISTING SWITCHGEARS WITH NEW EQUIPMENT LIKE TO LIKE (SAME RATINGS) DUE TO WATER DAMAGE.  REPLACE A 2,000AMP PULL SECTION, ONE 1,000 AMP AND ONE 800 AMP SECTIONS. NO NEW LOAD ADDED. ALL THE UNIT FEEDERS AND UNIT PANELS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33442	16041-10000-44630	12115 W BLUFF CREEK DR	90094	11	105B165   936	4211010103	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Issued	01/12/2017 12:00:00 AM	ADDRESS	33.97884	-118.4045	PC for energy only to existing office building. Interior TI adding new lighting and power. Total area: 901 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33443	18041-20000-14183	5451 N SADRING AVE	91367	3	174B093   493	2044007007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.16984	-118.6366	PC for PV rooftop solar 10.4kW(ac)/11.025kW(dc) for SFD. Installing 35 modules and two central inverter. See comments.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33444	19041-20000-53692	1126 S SANTEE ST	90015	14	124-5A209  41	5145022004	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Info Complete	09/14/2021 12:00:00 AM	ADDRESS	34.03702	-118.25659	Installation of new panels, new equipments, and lighting. Plan check for power and energy.B#19016-10000-41261	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33445	14041-20000-10805	6330 W SAN VICENTE BLVD #240	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.06116	-118.36804	T.I. to existing building partially on the 2nd floor.  Install general lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33446	18041-10000-33044	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	"Install sign lighting that reads: ""live beaming"", total area 5.11sq.ft in LAX terminal 1."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33447	14041-20000-01633	6728 S MCKINLEY AVE	90001	9	102B205   180	6007015012	M3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	33.97824	-118.26126	T24 FOR WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33448	16041-20000-24755	6615 N VALJEAN AVE	91406	6	180B137   263	2233031044	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.19077	-118.48601	PLAN CHECK PER APPLICANT.  REPLACE STAND UP SECTION TO 200 AMPS FUSE AND INSTALL NEW 200 AMP PANEL.JUNCTION BOX WITH POLARIS CONNECTORS SUBJECT TO FIELD VERIFICATION BY INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33449	15041-10000-25736	2855 S BARRINGTON AVE	90064	11	120B153  1011	4257011025	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.02282	-118.43914	PC FOR ENERGY ONLY , T-24 THE SCOPE OF WORK INCLUDES NEW LIGHTING IN AN EXISTING OFFICE BLDG. SQ FT = 1980.  6 CIRCUITS IN TOTAL: 3 CIRCUITS WERE PAID UNDER APP# 15041-10000-22146.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33450	13041-20000-35118	17508 W STRATHERN ST	91325	12	189B129   496	2201033002	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.21556	-118.51454	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33451	18041-10000-12901	15135 W SUNSET BLVD	90272	11	129B129   908	4423017023	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.04585	-118.52368	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33452	11041-20000-26590	13317 W VENTURA BLVD # E	91423	4	165B157   800	2360011028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	01/12/2012 12:00:00 AM	ADDRESS	34.14685	-118.42315	T24 plan check for remodeled space.  Change of use to bakery.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33453	15041-20000-42577	16704 W BAHAMA ST	91343	12	195B137   279	2688043008	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.23304	-118.4968	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.69KWac/6.0KWac.(29)MODULES-KYOCERA #KU2656ZPA(1)INVERTER- ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33454	11041-10000-26680	145 N HIGHLAND AVE	90036	5	138B185   181	5513007025	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.075	-118.33875	6.21KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33455	14041-20000-30427	13507 W RANGOON ST	91331	6	195B157  1022	2627003015	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.22801	-118.4267	PV1Install a roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 4.3kW.2 strings of 20 M215 microinverters connected to 20 250W pv modules (10+10).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33456	16041-20001-28139	4470-4474 W ADAMS BLVD 1ST FLR	90016	10	123B185   741	5050002018	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.03236	-118.33755	ENERGY CALCULATIONS TO INCLUDE FIRST FLOOR ONLY.  PERMIT FEES PAID UNDER MASTER APPLICATION.  THIS IS PLAN CHECK ONLY.  TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 6147.PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-30000-08136	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33457	12041-20000-10462	9501 N BALBOA BLVD	91325	12	201B133   598	2692002029	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			Corrections Issued	06/18/2012 12:00:00 AM	ADDRESS	34.24343	-118.50461	PV system for greek church. 90.72 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33458	18041-20000-45119	19241 W WELLS DR	91356	3	171B117   348	2163008006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Issued	12/20/2018 12:00:00 AM	ADDRESS	34.16382	-118.55276	Plan check for PV roof mounted system, system size: 24.48kW AC, 22.27kW AC CEC with 68 PV Modules and 68 microinverters connected to 400 Service.$40.27 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33459	11041-10000-05626	100 S WESTERN AVE	90004	4	138B193   964	5517006001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.07344	-118.30897	INTERIOR REMODELING OF EXISTING RESTAURANT-  SHIK DO RAK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33460	18041-10000-22588	333 S HOPE ST 34th FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Power and Energy on (E) office. TI with new loads > 400A, total area: 22,907 sq.ft. 34th floor.(B# 18016-10000-18050)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33461	19041-20000-16562	7513 N VASSAR AVE pv1	91303	3	186B101   347	2111001010	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Re-Activate Permit	05/19/2020 12:00:00 AM	ADDRESS	34.20694	-118.60468	pv1install roof mounted pv system sized 4.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33462	15041-20000-07072	10100 W SANTA MONICA BLVD Suite 300	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.06191	-118.41691	Title 24 plan check only.  Total area = 15,932 sq. ft.T.I. to 3rd floor of existing commercial highrise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33463	17041-10001-16675	1404 N CATALINA ST	90027	13	147B197  1085	5543017018	C2-1, [Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			Verifications in Progress	03/08/2019 12:00:00 AM	ADDRESS	34.09676	-118.29487	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATION OF EXISTING LIGHTING SYSTEM, LOAD CALCULATIONS, EQUIPMENT LOCATON AND SPECIFICATION. ALL CHANGES NOTED UNDER DELTA 1, 2 & 3.  ENGINEER CHANGE VERIFICATION REQUIRED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33464	10041-20000-03934	8723 W ALDEN DR 3RD FL	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM			PC Approved	03/04/2010 12:00:00 AM	ADDRESS	34.0754	-118.38272	Revisions to approved P/check under PCIS 09041-20000-10485 indicated as DELTA 4 on dwgs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33465	10041-10000-15783	6904 N TUJUNGA AVE	91605	2	183B173   176	2319005035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	ADDRESS	34.19577	-118.37887	PARTIAL TENANT IMPROVEMENT OF AN EXISTING WAREHOUSE TO PROVIDE SPACE FOR FURNITURE STORAGE RACKS AND BUILD OUT OF RELATED ADMIN  &  LOUNGE SPACES.STUDIO TENANCY #1  /  GLENDALE ANIMATION  PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33466	13041-20000-16479	8900 N DE SOTO AVE	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.23162	-118.58832	RENOVATION OF ROOM. NEW LIGHTS. ROOM FOR TEST EQUIPMENT. LAB. 128 SQ FT. NEW EMERGENCY FIXTURE IN SECOND ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33467	18041-20000-37528	4654 N LAUREL CANYON BLVD	91607	2	168B165   764	2355015001	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.15554	-118.39626	Plan check for power only. Project site is an existing commercial lot which has a gas station on it. Project scope is a new 800-amp service which will only serve (8) EV charging stations. New service does not provide power to gas station.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33468	12041-10003-30782	12751 W MILLENNIUM A	90094		102B161  1175	4211033020							Electrical	Electrical	Apartment			04/21/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	REVISION TO APPROVED PLANS. DELTA 38  CHANGED FIXTURES TYPE FROM FLUORECENT TO LEDS, REVISION OF ENERGY CALCS. ((PLAN CHECK POWER AND ENERGY FOR BUILDING A. FIRST LEVEL RETAIL WITH 3 STORY OF 96 UNITS RESIDENTIAL BUILDING ON TOP OF COMMON SUBTERRANEAN PARKING GARAGE. SITE LOCATED IN METHANE ZONE. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33469	18041-10000-09599	12801 W FOOTHILL BLVD	91342	7	216B161    26	2514004030	M1-1-CUGU	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.29216	-118.41349	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33470	13041-20000-27362	47 E WAVE CREST AVE 1-2	90291	11	108A143   215	4226003028	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	33.99046	-118.47481	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING 28 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 4 STRINGS WITH COMBINER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33471	13041-20000-33483	8407 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	34.22266	-118.62737	PC FOR T24 ENERGY ONLY. RELOCATION OF LIGHTING. NEW OFFICES. EXISTING SPACE LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33472	15041-20000-18174	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.21499	-118.4422	TI to existing commerical building (office). Plan check for energy only. Adding new lighting including emergency. Total sqft. 1,036.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33473	15041-20000-18994	5400 N BURNET AVE	91411	4	172-5A147  79	2250005019	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.16864	-118.46271	PV1.ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33474	17041-10000-33124	2146 W ADAMS BLVD	90018	10	123B189   692	5052031024	R3-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.03249	-118.31335	Install a new 150KW optional generator in a commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33475	19041-10000-20671	2460 E 12TH ST A	90021	14	120A217   143	5168005021	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.02255	-118.22799	PC (ENERGY ONLY) FOR TENANT IMPROVEMENT OF 6,595SF OF EXISTING OFFICE. b#19016-10000-11979	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33476	19041-20000-53833	3870 S CRENSHAW BLVD	90008	10	117B185   878	5033003002	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	03/25/2021 12:00:00 AM		Issued	03/25/2021 12:00:00 AM	ADDRESS	34.01525	-118.33474	New distribution equipment for future tenant improvements.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33477	19041-10000-21504	6255 W SUNSET BLVD Suite 716	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	Tenant improvement in an existing office area in Suite# 716 on the 7th Floor.Instaling new lights. T-24 Energy Only.Bulding Permit: 19016-10000-14442	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33478	17041-20000-12779	11623 W WASHINGTON PL	90066	11	114B157  1453	4214014005	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.00471	-118.42121	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM (E)  RETAIL TO (N) TO TAKE OUT RESTAURANT (1,293.6 SQ FT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33479	13041-20001-33436	11526 W BURBANK BLVD	91601	2	174B169   866	2350004039	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM			PC Approved	06/05/2015 12:00:00 AM	ADDRESS	34.17199	-118.3832	[6/5/15 CHANGES TO APPROVED SET OF PLANS. PLANCHECK ONLY. REDUCING ALL THE FEEDERS ON THE EXISTING DISTRIBUTION BOARD]]]REMODEL EXIST 2-STORY OFFICE BUILDING. NEW ELECTRICAL BUILD OUT. RELOCATION OF EXISTING 600A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33480	13041-20000-12381	7043 N TOPANGA CANYON BLVD	91303	3	183B101   257	2024002042	P-1VL, [Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			05/13/2013 12:00:00 AM			PC Approved	05/13/2013 12:00:00 AM	ADDRESS	34.19864	-118.60617	TI FOR EXISTING RETAIL SPACE. 1800 SQRFT. PART OF A NON HIGHRISE STRIP. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33481	12041-20000-07964	1898 N STANLEY AVE	90046	4	150B177   395	5551010018	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2012 12:00:00 AM			Reviewed by Supervisor	04/17/2012 12:00:00 AM	ADDRESS	34.1046	-118.35771	Roof mounted PV System using Enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33482	17041-10000-08165	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.97954	-118.42015	Plan check for fire alarm system for commercial building. Total devices 118 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33483	14041-10000-24489	621 W 117TH ST	90044	15	084B201   472	6088012016	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	01/16/2015 12:00:00 AM		Refund in Progress	05/24/2016 12:00:00 AM	ADDRESS	33.92747	-118.28568	PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): POWER-ONE AURORA PV1-5000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33484	14041-20001-17234	11332 W CHENAULT ST	90049	11	135B149   595	4365010031	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.06259	-118.45851	PV1.  Install 5.8 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.Zoning clearance obtained before starting of this application under 14041-20000-17206	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33485	16041-20000-03731	5161 N LANKERSHIM BLVD 350	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.16452	-118.37469	Plan check for power and energy. General office TI and new EPS system for Server room. 19,235sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33486	16041-20000-08586	6330 W SAN VICENTE BLVD Suite 500	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.06116	-118.36804	Plan check for Title 24 only. Project site is an existing commerical building. Project scope is a tenant improvement. Total lighting area = 8,383 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33487	19041-20002-13132	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.02198	-118.33376	Revisions to approved set - approval for delta 6 change only.  SLD reconfiguration and change of source for bathroom exhaust fans.  <<<Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from warehouse to office and parking garage and the addition of a 2nd floor. Work includes a new 1,200-amp service and a total lighting area of 42,690 sq. ft.Note: Building permit has been issued under 18014-10000-04633>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33488	15041-20000-40294	7423 N LOMA VERDE AVE	91303	3	186B109   630	2112013008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.20532	-118.58973	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (20) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33489	18041-10000-39834	10150 N LOUISE AVE	91325	12	204B133   323	2694015029	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.2556	-118.51091	NEW 5.7KW ROOF MOUNTED PV SYSTEM WITH 16 AC MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33490	19041-20000-32169	11821 N WOOD RANCH ROAD	91344	12	216B129   342	2601065016	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.28586	-118.51981	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 13.42KW DC/10.56KW AC. SCOPE OF WORK CONSISTS OF (44) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33491	17041-10000-35060	1500 E BRIDGE ST	90033	14	130-5A221  54	5174010049	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.05323	-118.2201	PC for T24 only for outdoor lighting. Replacing HID fixtures and replacing with new LEDfixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33492	15041-20001-36704	11505 N VIMY ROAD	91344	12	213B129   228	2601037045	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM			PC Approved	11/30/2015 12:00:00 AM	ADDRESS	34.28018	-118.52193	EXPEDITE PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.4KWac. (36) MODULES-SUNPOWER SPR-E20-327(36) OPTIMIZERS-SOLAREDGE P400(1) CENTRAL INVERTER-SOLAREDGE SE11400A-US))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33493	16041-20000-41324	706 E MANCHESTER AVE A-E	90001	9	097-5A207 307	6042002031	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	33.95987	-118.26271	INSTALLATION OF NEW FIREALARM SYSTEM. 1 FACP AND 51 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33494	15041-10001-31717	266 S HARVARD BLVD STE 200 &-205	90004	10	135B193   181	5517019030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM			PC in Progress	02/26/2017 12:00:00 AM	ADDRESS	34.06926	-118.30396	02/22/16PC FOR A LOST SET OF PLANS FOR A 4-STORY AMBULATORY SURGERY CENTER (OSHPD 3 LICENSED)Note: Permit is paid under PCIS#15041-10000-31717	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33495	10041-10000-12783	500 W WORLD WAY MCP-03	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-03. This applicaation separates MCP-03 from the entire project on PCIS 09041-10001-24166( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33496	11041-10001-01464	939 N WESTERN AVE	90038	13	144B193  1184	5535006027	C4-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Approved	02/25/2011 12:00:00 AM	PIN	34.08785347	-118.30939619	Addition of an exterior lighting. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33497	14041-20001-01948	7047 N FIRMAMENT AVE	91406	6	183B141   300	2222036009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.19884	-118.47263	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33498	17041-20000-32561	3623 W LANDA ST	90039	4	147A203   473	5431012004	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Issued	10/12/2017 12:00:00 AM	ADDRESS	34.09541	-118.2741	Installation of 13.5 kWh energy storage system.  (E) solar reconnected to new subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33499	16041-10000-22433	10844 W LINDBROOK DR	90024	5	132B153   242	4360003028	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.06013	-118.44228	provide temporary  (12 months) emergency power from Center West Building (14041-10000-31457) to the Lindbook Dr building.Attached to the plans are the variance and covenant of ownership	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33500	16041-10000-15437	1400 W 190TH ST	90501	15	060B193   446	7351002020	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Info Complete	05/05/2016 12:00:00 AM	ADDRESS	33.85811	-118.30226	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL BUILDING (AT&T).  SCOPE INLCUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1010 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33501	19041-20001-23187	5670 W WILSHIRE BLVD 6TH FLOOR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			Corrections Issued	08/12/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	7/18/19changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.  ((((TI IN COMMON AREAS & CORRIDORS OF THE 6TH FLOOR. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.  1,099 SQR FT.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33502	15041-20005-08533	6344 N TOPANGA CANYON BLVD #1050	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM			PC Approved	10/07/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	"10/07/2015 Changes to an approved set of plans. Changs include the resizing of the HPs and some of the feeders. All changes have been clouded.09/09/2015 Changes to an approved set of plans. Changes include the addition of a fused disconnect on the secondary side of the transformer and changing the feeder. All changes have been clouded and marked as Delta 5.*****Previous Work Description*****Changes to an approved set of plans. Delta 3 changes. Changing 65W light fixture with 50W.(((Plan check for power and energy for first time tenant (new restaurant = Tender Greens). Total area: 3177 sq ft. Part of Building A of ""Westfield Topanga"" mall.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33503	12041-20000-21616	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for energy and emergency lighting. 1761 sqft. Ruby Thai Kitchen. Inside a mall food court.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33504	11041-10000-26091	500 S VIRGIL AVE #205	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	07/11/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Plan check power and energy for medical office #205 TI.  Existing building with new service under #11041-20000-20785	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33505	10041-20000-13107	8013 W MELROSE AVE	90046	5	141B177   550	5527014003	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM			PC Approved	07/09/2010 12:00:00 AM	ADDRESS	34.08391	-118.36425	Changes from previously approved plans 10041-20000-12717.  Type A fixture change as shown on plan.   Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33506	18041-10000-34504	4425 S 7TH AVE	90043	8	111B189   371	5014012015	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.00291	-118.32481	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 12 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.TOTAL SYSTEM SIZE 4.32 KW DC / 3.0 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33507	19041-10000-07749	700 S FLOWER ST 4th Floor-Ste. A	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	T-24, TENANT IMPROVEMENT FOR MINIMAL LIGHTING IN AN OFFICE SPACE. SUITE A. SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 2736 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33508	15041-10007-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM			PC Info Complete	02/12/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	DELTA 20, 21 & 22 CHANGES TO APPROVED PLANS PER ATTACHED NARRATIVES. <<<Pc for power and energy for replacement/upgrade of the mall distribution system, common area lighting, and receptacles. New HVAC, additional generator, replacement of outdate panels and meter centers. upgrade a couple of services and refeed existing tenants.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33509	18041-10000-01870	264 S UNION AVE	90026	13	133-5A207  23	5153010011	R3-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Apartment			01/17/2018 12:00:00 AM	07/16/2019 12:00:00 AM		Issued	07/16/2019 12:00:00 AM	ADDRESS	34.06175	-118.26723	3 STORY 12 UNIT APARTMENT BLDG, OVER 1 LEVEL SUBTERRANEAN GARAGE. SERVICE RATED 120/240 Volts, 1 Phase, 3 Wire; Meter Switch Amps: 400;  Fault Current: 32,000 Amps AIC; Switchboard Info: 1000A PS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33510	11041-20000-23398	16830 W SAN FERNANDO MISSION BLVD	91344	12	210B133   998	2683028038	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	12/15/2011 12:00:00 AM	ADDRESS	34.27181	-118.49871	T24 ENERGY TI TO PHARMACY. EXISTING VONS MARKET. PERMIT FOR NEW BRANCH CKTS AND NEW LIGHTING ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33511	15041-20001-36497	20953 W HEMMINGWAY ST	91304	3	189B109   513	2109013018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM			PC Approved	11/09/2015 12:00:00 AM	ADDRESS	34.2145	-118.59038	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (25) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33512	17041-20000-10883	1813-1817 N NEW HAMPSHIRE AVE	90027	4	150B197  1110	5589029025	R3-1	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Apartment			04/04/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Issued	12/28/2017 12:00:00 AM	ADDRESS	34.1039	-118.29345	Plan check for power only.  Project site is an existing 8 unit apartment building.  Project scope is a service upgrade to 600 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33513	12041-20000-25577	5850 N CANOGA AVE 4th & 5th-floor	91367	3	174B105     9	2149002016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.17678	-118.59723	New and relocated lighting and receptacle outlets in various room of the 4th and 5th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33514	16041-10000-04254	9204 S AIRPORT BLVD	90045	11	093B169    88	4125022017	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	33.95224	-118.38566	CHANGES USE AND MODIFY EXISTING BUILDING FOR NEW CAR WASH. NEW 600A SERVICE. REFEED EXISTING PANEL C. NEW LOADS ASSOCIATED WITH CAR WASH EQUIPMENT. NEW LIGHTING. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33515	14041-10000-00040	701 E NEW DOCK ST CHECK-IN-TRAILER	90731	15	024B209   298	7440021914	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.75567	-118.25325	NEW FIRE ALARM SYSTEM FOR CHECK-IN TRAILERS OF 48 DEVICES, 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33516	14041-10000-14665	101 S MISSION ROAD	90033	14	129A217   111	5172013013	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.04758	-118.22819	TI, TITLE 24, NO EMERGENCY LIGTHING, ONE STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33517	15041-20001-37216	7118 W GREELEY ST	91042	7	202-5A201 372	2568014016	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM			PC Approved	05/25/2016 12:00:00 AM	ADDRESS	34.24888	-118.28667	[ 5/25/16 CHANGES TO APPROVED SET. MODULES REDUCED TO 17, INVERTER SIZE AND MODEL CHANGED TO 3.8KW AND PV BREAKER SIZE REDUCED TO 20 AMPS.]]]PV1, 5.00KW AC roof mounted system with (21) Q Pro BFR-G4 modules, and (1) Solaredge SE5000A inverter interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33518	14041-20000-31736	14373 W BEAVER ST	91342	7	219B149   575	2507023019	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.29608	-118.44666	PV1 SFD. TOTAL SYSTEM SIZE 8KW AC USING 2 CENTRAL INVERTER SYSTEMS. TRANSFORMERLESS TYPE. TOTAL OF 22 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33519	13041-10000-25768	505 S VIRGIL AVE ste 104	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.0649	-118.28724	TITLE-24 ONLY; WORK IS FOR INTERIOR TENANT IMPROVEMENT FOR DOCTOR'S OFFICE, IN STE 104. NO SURGICAL OPERATION WILL BE DONE IN THE DOCTOR'S OFFICE PER APPLICANT. TOTAL AREA IS 1970 SF. PERMIT TO BE PULLED @ THE ELECTRICAL PLAN CHECK COUNTER 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33520	12041-10001-24201	4225 S CENTRAL AVE	90011	9	114A209   153	5115019033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.00695	-118.25669	((( CHANGES MADE TO APPROVE SET OF PLANS. SOME CHANGES MADE TO DEVICES, OVERALL NO DEVICES HAVE BEEN ADDED. EXISTING FIRE ALARM PANEL)))NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING FOR A BUILDING CHANGED FROM A HOTEL TO  APARTMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33521	18041-20000-13383	6180 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	ADDRESS	34.18261	-118.39631	New four story parking structure with four single-story tenant buildings at grade.  Buildings supplied through 34.5 kV loop distribution (under separate permit).  Plan check for power and energy.  Associated building permits under 16010-10000-05907/05917/05918/05919/05920.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33522	17041-10001-23278	8500 W BEVERLY BLVD UNIT 112	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM			PC Approved	03/30/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	Supplemental PC for T24 only for revised lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33523	16041-20000-05745	21834 W RODAX ST	91304	3	192B105   337	2779039003	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.22341	-118.60413	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 5 kWac for a total system size of 11 kWac. Addition consists of (1) inverter, (22) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33524	18041-10000-17508	6919 S KNOWLTON PL #1	90045	11	102B173   303	4103012005	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	06/09/2021 12:00:00 AM	ADDRESS	33.97436	-118.37145	CORE & SHELL FOR THE INSTALLATION OF A 600 AMP SERVICE AND 5 PANELS FOR 5 SINGLE FAMILY HOMES. UTILITY EASMENTS WERE FILED FOR THE SUBDIVISION TO BE VERIFIED DURING PLAN CHECK.BUILDING PERMIT # 16010-30000-01380	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33525	15041-10001-19418	4357 W WILSHIRE BLVD	90010	4	132B189    16	5505022013	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.06198	-118.32315	( 12/15/2016) REVISION TO THE APPROVED SET OF PLAN. CHANGES REFLECTED AS DELTA 5 ON THE PLAN INCLUDING CHANGE OF CIRCUITRy AND SERVICE  AND ADDITION OF SOME PANELS.permit is issued for additional items only. see inspection fee. also checking for lighting revision. updated t24 provided	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33526	19041-10000-46834	384 WORLD WAY SPACE M23	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Info Complete	11/20/2019 12:00:00 AM	ADDRESS	33.94339	-118.40887	"FIRST TIME TENANT IN UNIT #M23 - COMMERCIAL / RETAIL SPACE IN TERMINAL ""MSC"" IN LAX. INSTALLING PANELS, CIRCUITS & LIGHTS.  PLAN CHECK FOR POWER & ENERGY. AFFECTED AREA: 1,105 SFT ***M23 - MIXOLOGY 101***"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33527	16041-30000-16344	9225 N ALABAMA AVE #C	91311	12	198B105   108	2746011***	[Q]MR2-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Closed	05/29/2018 12:00:00 AM	ADDRESS	34.23805	-118.59986	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement/change of use from warehouse to food processing and commercial kitchen. Total lighting area = 1,542 sq. ft.Note: Building application has been created under 16016-30000-10193	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33528	13041-10001-24134	5760 W ARBOR VITAE ST	90045	11	093B169    79	4125020014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	33.9525	-118.38238	EXPEDITED PER APPLICANTS REQUEST.PV3. NEUTROGENA MANUFCATORING PLANT. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 233.240 KW DC. 225KW INVERTER. 952 MODULES.  1 OF 2 BUILDINGS ( DIFFERENT ADDRESSES)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33529	16041-20000-28678	7257 N PONDERA CIR	91307	12	183B093    44	2027012005	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.20155	-118.64219	Install a roof-mounted solar array on a SFD. Interconnect with a 150A MSP. Derating main breaker to 100A. 7.6kW ungrounded system. (29) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33530	14041-10000-32249	14100 W MULHOLLAND DR	90210	5	159B153   200	4382024005	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Expired	09/05/2023 12:00:00 AM	ADDRESS	34.13091	-118.43937	Full plan check for power and lighting. Project site is a two-floor, single family dwelling. New 1,200 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33531	10041-10000-08602	189 S THE GROVE DR #  O-20	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	10/15/2010 12:00:00 AM	ADDRESS	34.07125	-118.35662	T.I. for existing building.  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33532	16041-10001-23184	5030 W PICO BLVD	90019	10	129B181  1009	5070017006	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM			PC Info Complete	10/28/2016 12:00:00 AM	ADDRESS	34.04766	-118.34728	10/28/2016 Changes to an approved set of plans. Changes include lighting fixture manufacturer and lighting layout. Changes apply to delta 2 only. ((((((PC FOR ENERGY ONLY. T.I. FOR AN ISRAEL GALLERY. TOTAL AFFECTED AREA IS 5200 SQ FT.SCOPE INCUDES NEW LIGHTS AND RECEPTACLES. B# 16016-10000-15166)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33533	17041-20001-45635	8335 N SPARTON AVE	91402	6	192B157   605	2637034020	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			Reviewed by Supervisor	12/28/2017 12:00:00 AM	ADDRESS	34.22247	-118.42589	Expedited plan check fee.PV1.  Install 14.26 kW AC roof mounted grid tied PV system.  (58) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33534	17041-30002-20927	11731 W RUNNYMEDE ST Units 1-4	91605	2	186B169   544	2317010006	(T)(Q)RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			09/13/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.20585	-118.38887	09/13/2018 Plan check for Title 24 only. Project site is a 3-story, 4-unit apartment building. Project scope is outdoor lighting. Total lighting area = 1,526 sq. ft.Note: Building permit has been issued under 14010-20000-01814*****Previous Work Description*****SUPPLEMENTAL TO PERMIT #17041-10000-20927 TO ADD CIRCUITS (60), LIGHTS/OUTLETS (280),SMOKE DETECTORS (20), (1) MAIN PANEL  AND (5) SUBPANELS*****Original Work Description*****5 GANG METER INCLUDING HOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33535	15041-20000-15735	12045 W GUERIN ST	91604	2	165B165   989	2368004012	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Apartment			05/21/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.14635	-118.39389	Plan check for new fire alarm system for a new 4 story apartment building. 110 devices. 1 FACP. 1 ANN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33536	14041-10000-04048	942 N YALE ST	90012	1	135A215    46	5414004006	C2-2D	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.0661	-118.23918	This is a two story church , new fire alarm 105 devices , 1 panel and 2 control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33537	15041-10000-24065	1500 W PACIFIC COAST HWY Bldg F2	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 2-story, 2 unit apartment with garage, . 9 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33538	16041-10000-28863	9188 N GLENOAKS BLVD	91352	6	198B173   103	2408003041	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.23589	-118.37251	REPLACEMENT OF OUTDOOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33539	17041-20000-19464	2872 N LAS ALTURAS ST	90068	4	156A181   511	2428012008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	Yes	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.12121	-118.34915	Plan check for a PV1 roof-mounted PV system. System size is 8 kWac and consist of (32) modules, (32) micro-inverters, and (1) load center. System interconnects with a 400-amp rated MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33540	18041-20000-19629	8201 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.21793	-118.6063	PLAN CECK FOR POWER AND ENERGY FOR - New supermarket in an existing commercial shell space.  (E) distribution with new subpanels. SCOPE INCLUDES CONNECTING TO EXISTING SERVICE RATED AT 1600A 277/480. TOTAL NEW CONNECTED LOAD = 1400A, TOTAL AFFECTED AREA = 61607 SF Building permit under 18016-10000-16484.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33541	13041-20000-30715	6320 N CANOGA AVE #800E	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Issued	11/04/2013 12:00:00 AM	ADDRESS	34.18499	-118.59722	Exiting high rise office building, all circuits are existing.  Change to lighting. PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33542	19041-10000-12017	5535 E YORK BLVD	90042	14	154-5A227  10	5478025002	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.11962	-118.19698	T-24 energy only plan check for a TI to a change of use from retail space to cafe/lounge with seatings. Scope includes new panel, circuits, lighting and receptacles. total affected area is 1342 sq.ftPartial permit fees are paid under express permit # 19041-10000-07101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33543	11041-10000-15962	5815 W SUNSET BLVD 1-90	90028	13	147A191    49	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	05/23/2012 12:00:00 AM	ADDRESS	34.09822	-118.31613	Core and shell of a 3-story building.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33544	12041-20000-23191	13833 W VENTURA BLVD 101	91423	4	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	09/28/2012 12:00:00 AM	ADDRESS	34.1487	-118.43426	Plan check for energy and emergency lighting. Changes to approved plans for 08041-20000-05790. Unit 101. 544sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33545	16041-20000-27971	841 W 55TH ST	90037	9	108B197   685	5001007021	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	33.99244	-118.28851	Install a roof-mounted solar array on a SFD. Interconnect with a 125A MSP.4.9kW ungrounded system. (15) 327W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33546	13041-20000-12775	231 S PLYMOUTH BLVD	90004	4	138B189  1294	5515022018	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00, 2115.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	34.07037	-118.3226	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 3.47 KW. [INVERTER: SUN POWER SPR4000M] [PV MODULE: SUN POWER SPR-327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33547	15041-20000-22755	15157 W ROSCOE BLVD	91402	6	192B145   371	2654024013	(T)(Q)RAS4-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Apartment			07/17/2015 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.22161	-118.46296	Plan check for New 39 unit appartment. 1600A service. Total area 39817 sqft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33548	18041-10000-32786	16200 W MULHOLLAND DR	90049	11	159B137   491	4490003005	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.12965	-118.48562	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33549	13041-20000-35550	5639 E RABER ST	90042	14	157-5A227 105	5480033005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.12671	-118.19518	PV1 GROUND MOUNTED SYSTEM. TOTAL SYSTEM SIZE 5KWAC 3 STRINGS FOR 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33550	19041-20000-49741	1630 N SILVERWOOD TER	90026	13	144A205   394	5423017023	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/18/2020 12:00:00 AM	ADDRESS	34.08792	-118.2677	PV1.  Install 6.5 kW DC / 5.891 kW CEC-AC PV system with 13.5 kWh energy storage system.  (20) modules with (10) microinverters and (2) sub panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33551	10041-10000-10098	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	08/11/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	FIRST TENANT (CHASE BANK )  ON THE GROUND FLOOR OF A MIXED USE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33552	17041-20000-30167	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.21445	-118.48429	Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size is 400 kWac. Ground-mounted portion of the system is 124 kWac and consists of (3) inverters, (404) modules, and (1) load centers.Note: Building permits for the ground-mounted carport system have been issued under building permits 17010-30000-03239/03464/03465. Roof-mounted portion of the system has application number 17041-20000-30164.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33553	19041-10000-19417	6160 N LAUREL CANYON BLVD ste 180	91606	2	177B165  1100	2334011029		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	PC FOR POWER AND ENERGY FOR A FIRST TIME BUILD-OUT INTERIOR SPACE TO A FAST CASUAL DINING PIZZA RESTAURANT. SCOPE OF WORK INCLUDES NEW PANELS, TRANSFORMER AND CIRCUITS. TOTAL SQ. FT. 2610.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33554	18041-10001-02657	700 N ALAMEDA ST	90012	14	132A215   180	5409023930	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	34.05488	-118.23748	Plan check only. Delta 6 changes to an approved set. Relocating 3 office spaces. Addition of 3 circuit to 3 existing panels.Scope of work: ((PC for power and energy for renovations project for Metropolitan water district building. Scope includes new lighting, new panels, receptalces and equipment including UPS in electrical rooms. Total area is 312870sqft. B# 15016-10000-22112. Note that previous parking lighting was approved under expired plan 15041-10000-32385.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33555	11041-10000-19737	11100 W SANTA MONICA BLVD 12th floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/28/2011 12:00:00 AM	ADDRESS	34.04726	-118.44465	T24 and emergency lighting plan check for floor 12	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33556	16041-10000-45671	327 N WILMINGTON BLVD BLDG 4	90744	15	027B205   659	7417010937	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM				PC for new fire alarm panel with 42 devices and 2 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33557	14041-10000-34511	222 E 11TH ST	90015	14	126A209   271	5145021010	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Closed	02/03/2015 12:00:00 AM	ADDRESS	34.03789	-118.25659	T24, REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 1476 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33558	15041-10000-40883	18620 S WESTERN AVE	90248	15	060B193   249	6108002019	C2-1, P-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	33.86143	-118.30895	PC FOR POWER AND ENERGY  , DENNIS RESTURANT. T.I. REPLACING 600A SWEACHGEER WITH THE EXACT ONE AND ADDING 3 200A PANEL. TOTAL AREA 1691 SQ FT, INCLUDING OUTDOOR AND INDOOR. PLAN CHECK ONLY. PERMIT FOR SWEACHGEAR IS UNDER 15041-10004-0576	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33559	16041-30001-32232	5529-5531 W WASHINGTON BLVD	90016	10	126B177  1593	5064017001	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			Corrections Issued	05/23/2017 12:00:00 AM	ADDRESS	34.03732	-118.36418	Plan check for Title 24 only in existing space T.I. retail. Total area: 1967 sq ft. Plan check only. Permit refer to 16041-30000-32232	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33560	19041-20000-53208	2405 S HAUSER BLVD	90016	10	123B177   528	5063007090	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM	04/13/2021 12:00:00 AM		Permit Finaled	04/24/2023 12:00:00 AM	ADDRESS	34.03491	-118.36208	INSTALL NEW 2000 AMP 208 SERVICE, PANELS, EQUIPMENTS AND LIGHTING.B#19010-10000-04872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33561	17041-20000-14652	1335 S ABBOT KINNEY BLVD	90291	11	108B145  1240	4239027009	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	33.99097	-118.46678	TI to (E) retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33562	17041-10001-00492	776 W 1ST ST	90731	15	018B197  1078	7451004017	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	33.74341	-118.29398	Expedited Fees.********************************************************PV2 roof mounted solar sytem installation. Triplex residence. Central inverter rated at 6.6 KW and 25 solar modules, load center included rated at 125 Amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33563	11041-20002-27230	8105 W BEVERLY BLVD	90048	5	138B177   405	5514007051	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Approved	04/20/2012 12:00:00 AM	ADDRESS	34.07625	-118.36615	Modification to previously approved set of plan.  Plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33564	14041-20002-18509	13159 N BRADLEY AVE	91342	7	222B145    22	2501006029	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2014 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.30904	-118.46482	FEE CHARGE IS $0.00 DOLLARS BY STATE SENATE BILL NO. 1222SUPPLEMTAL PERMIT TO RELOCATE INVERTER AND SECONDARY DC DISCONNECT SWITCH INTO THE INSIDE WALL OF THE GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33565	16041-30000-03760	952 S HILGARD AVE	90024	5	135B153   623	4360006017	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Expired	03/02/2018 12:00:00 AM	ADDRESS	34.06233	-118.44133	Replace existing FACP to accomidate elevator.  New modules and control relays.  7 new smoke detectors + 2 new heat detectors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33566	15041-10000-07289	320 S HAMPTON DR	90291	11	111B141   717	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Public Safety Only			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	33.99612	-118.47637	NEW FIRE WARNING SYSTEM FOR 2-STORIES COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33567	12041-10000-24273	11949 W FOXBORO DR	90049	11	132B141   146	4404017004	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.06058	-118.47367	NEW PV SYSYETM ON THE ROOF OF A SINGLE FAMILY HOUSE.  <<PV1>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33568	17041-10001-40428	3787 S REDWOOD AVE	90066	11	111B149  1077	4245023019	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	33.99806	-118.44615	EXPEDITE PER APPLICANT REQUESTPC FOR 3.8KW ROOFTOP PV SYSTEM. INSTALING 14 MODULES, CENTRAL INVERTER AND 200AMP LOAD CENTER.SYSTEM IS CONNECTED WITH POWERWALL BATTERY THAT IS COVERED UNDER #17041-10002-40428	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33569	11041-10001-07334	1839 E 42ND ST	90058	9	114A215    77	5116027029	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.0061	-118.24032	MODIFICATION TO T-24 FOR PREVIOUSLY APPROVED SET OF PLANS.  PLAN CHECK IS FOR ENERGY ONLY.  <<<<<T.I. OF BUILDING FROM A COLD STORAGE TO POULTRY PROCESSING BUILDING.  SERVICE UPGRADE, BRANCH CIRCUITS, AND EQUIPMENT LOADS.>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33570	17041-10000-38466	10409 N CANBY AVE	91326	12	204B125    39	2731013015	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.2596	-118.53515	install new Rooftop solar system on a SFD. system is 5KW ac (20 modules) (1 inverter)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33571	15041-10001-15254	6150 W 96TH ST	90045	11	093B165   121	4124027906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM			PC Approved	03/10/2016 12:00:00 AM	ADDRESS	33.94871	-118.39284	03/10/16CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 6 ONLY, CHANGES INCLUDE THE CHANGE OF VOLTAGE CLASS, PANEL LOCATIONS, SINGLE LINE DIAGRAM  AND LOAD TO MODULAR TRAILORS. PC ONLY. (((CONNECT NEW FEEDERS TO EXISTING 600 AMP DISTRIBUTION BOARD TO ENERGIZE MODULAR TRAILERS ((UNDER SEPARATE PERMIT)) AND SITE LIGHTING FOR OPEN PARKING LOT.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 107,600)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33572	15041-10000-32905	642 E 51ST ST	90011	9	111A207   285	5103001008	R2-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	33.99641	-118.26407	pv1, insatall 5.83 kw dc roof-mounted solar array on a single family house. (22) modules: KYOCERA KU2656ZPA(I) INVERTER:ABB PVI- 5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33573	12041-20000-07087	13007 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.18799	-118.41633	energy plan  check pizza place	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33574	16041-10001-02671	1229 W 38TH ST	90037	8	117B197   448	5037013030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.01743	-118.29841	02/08/16Changes to an approved set of plans. Changes include adding a new 125A Subpanel, and new sized conductors tying into existing 100A main service panel. Note: permit paid under PCIS#16041-10000-02671 ((((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac. (12)MODULES-KYOCERA # KU2656ZPA(1)INVERTER- ABB# PVI-3.0-OUTD-S-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33575	11041-20000-08714	800 S FIGUEROA ST #810	90017	9	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	34.04771	-118.26116	T.I. to existing high rise building of 8th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33576	10041-10001-03491	10880 W WILSHIRE BLVD 10th floor	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM			PC Approved	06/15/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	Change the priviously approved plan. Add 10 new Fluorescent Lights. Plan checheck for delta 1. ((((((((((((((( Tenant improvement in existing office spaces. plan chk is for title 24 and 11 ea emergency ckt )))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33577	15041-10000-05308	200 WORLD WAY 231	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Energy plan check for internal signage in the airport (starbuck).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33578	12041-10000-27587	17921 W CHATSWORTH ST	91344	12	207B129   356	2715025048	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.26509	-118.52406	TI in an existing retail store. EPC is for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33579	13041-10000-33856	1513 S GRAND AVE	90015	14	124-5A207 123	5134015027	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.03622	-118.26632	PLAN CHECK FOR T24 ENERGY ONLY. SCOPE IS CHANGE OF DRESSING ROOMS INTO RECPETION / NURSE STATION AND PARTIONING ONE ROOM INTO 2 ROOMS. 4 TH FLOOR. 895 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33580	17041-20000-10648	10431 N WOODLEY AVE	91344	12	207B141   845	2679009005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Closed	02/08/2024 12:00:00 AM	ADDRESS	34.26022	-118.48503	pv1install roof mounted pv system sized 3kw interconnected with msp.this system is an addition to an existing system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33581	11041-10000-15072	8224 S BROADWAY	90003	9	099B201  1199	6031032900	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.00	Electrical	Electrical	Public Safety Only			07/19/2011 12:00:00 AM	07/19/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	33.96436	-118.27809	INSTALLATION OF FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING OF THE SPRINKLER SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33582	16041-20000-29445	12160 W HART ST	91605	2	183B165   272	2321009043	R3-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.1974	-118.39855	NEW FIRE ALARM SYSTEM 95 DEVICES 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33583	18041-30000-06288	100 W WORLD WAY DEPART-LVL	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	PIN	33.94684048	-118.40128468	FULL PC FOR POWER AND ENERGY FOR  FIVE (5) FAST FOOD FACILITIES@TERMINAL ONE, AND (3) STORAGE ROOMS. SCOPE OF WORK INLCUDES NEW LIGHTING AND RECEPTACLES, TOTAL CONNECTED AMPS > 400A. TOTAL SQ. FT. IS 4300. B#18041-30000-06288	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33584	15041-20001-42177	11100 W SANTA MONICA BLVD 9TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	09/24/2016 12:00:00 AM	ADDRESS	34.04726	-118.44465	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES REFLECT DELTA C ONLY.T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 9TH FLOOR (OFFICE SPACE). SCOPE INCLUDES A NEW 225A PANEL AND NEW LIGHTING. TOTAL AREA IS 12,310 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33585	16041-10000-00819	11318 W SANTA MONICA BLVD	90025	11	129B149   524	4261009032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM			PC Approved	01/11/2016 12:00:00 AM	ADDRESS	34.04615	-118.44897	T-24, TI TO AN EXISTING FILM COMMERCIAL BUILDING SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. TOTAL SQ. FT. 7395.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33586	14041-10000-18962	221 W 2ND ST	90012	14	130-5A213  20	5149001004	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.05214	-118.24607	PC FOR POWER. ELECTRICAL DEVICES FOR INSTALLATION OF THE EMERGENCY GENERATOR FUEL STORAGE ROOM AND UPGRADE TO HVAC. HAZAREOUS LOCATION.BUILDING APP #: 14016-10000-07801	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33587	19041-10000-20057	9001 N CANOGA AVE	91304	3	195B105    52	2779018031	[Q]MR2-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.23389	-118.59777	Replace fluorescent troffers with new LED retrofit kits - Indoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33588	15041-10000-31814	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.09786	-118.29745	PC FOR POWER AND ENERGY. 6-STORY KAISER PERMANENT MEDICAL OFFICE BULDING. ADDITION OF ONE ACCELARATOR, (LINEAR ACCELARATOR)  LENAC,  CT SIMULATOR  AND SOME LIGHTING. WORK TO BE DONE ON FIRST FLOOR AND BASEMENT. TOTAL AREA 1916 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33589	18041-10000-05843	21345 W DEERING CT	91304	3	189B105   117	2109001020	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Closed	02/13/2024 12:00:00 AM	ADDRESS	34.21659	-118.59627	PC FOR FOR POWER AND ENERGY TO A change of use from auto repair into hydroponic agricultural enterprise add 2nd story inside 1 story volume. TOTAL CONNECTED LOAD >400A.SCOPE INCLUDES NEW PANELS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 2350 SQ.FT INDOOR AND OUTDOOR.B#18014-30000-00854	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33590	15041-10000-09437	8315 N LAUREL CANYON BLVD	91352	6	192B165   439	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.22208	-118.39764	TI PROJECT IN A PREVIOUS RESTAURANT SPACE FOR A NEW PANDA EXPRESS RESTAURANT;plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33591	18041-10000-46436	6420 W WILSHIRE BLVD # 1800	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.06365	-118.36922	TENANT IMPROVEMENTS IN EXISTING OFFICESPLAN CHKE IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33592	14041-10001-01570	15200 W MORRISON ST	91403	4	168B145   116	2263017035	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.16019	-118.46417	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 6.25 kW DC roof-mounted solar array, interconnect with exsisting service panel. (1) Transformerless inverter(s):n Solaredge SE6000A-US. (25) Modules TRINA SOLAR TSM-250PA05.18.(25) Optimizer:SOLAREDGE OP250-LV-MC4SM-2NA-Z.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33593	19041-10000-29442	8406 N ZEILER AVE	91402	6	192B157   490	2637014048	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	09/21/2019 12:00:00 AM	ADDRESS	34.22349	-118.42505	NEW ROOF MOUNTED 4.8 KW (DC) PV SYSTEM WITH 17 PV MODULES AND 1  INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33594	16041-30001-29379	3831 S HUGHES AVE Parking P1-P4	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.02242	-118.39823	07/25/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4. Details were removed per inspector's request.*****Previous Work Description*****Plan check for Title 24 only T.I. in existing parking structre 4 levels P1, P2, P3&P4. Total lighting area: 93,470 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33595	13041-10000-31671	550 S HOPE ST	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/27/2013 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLAN CHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR HOPE CAFE. HIGH RISE, RIGHT NEXT TO THE LOBBY. CONNECTED LOAD UNDER 400< AMPS. 771 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33596	19041-30000-04245	771-777 N VIRGIL AVE	90029	13	141B197   209	5539017001	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.08536	-118.28701	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement and repartitioning of an existing space to create (3) separate core and shell tenant spaces. Total lighting area = 4,270 sq. ft.Note: Building application has been generated under 18016-10000-33068	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33597	16041-10001-36476	440 N VIRGIL AVE	90004	13	141A201   352	5539035028	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM			Reviewed by Supervisor	10/27/2016 12:00:00 AM	ADDRESS	34.07898	-118.28659	Expdited RSES PC per applicant request.************************************************************************************PV, INSTALLATION OF 5.520 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MICROINVERTERS: SUNPOWER SPR-X1-345-C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33598	10041-10001-17578	1357 N HIGHLAND AVE	90028	4	147A185   253	5548024044	C2-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Public Safety Only			09/10/2010 12:00:00 AM			PC Approved	09/10/2010 12:00:00 AM	ADDRESS	34.09598	-118.33883	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING; PERMIT WAS FIRST OBTAINED ON 10041-20000-17578	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33599	18041-20001-39640	12024 RICASOLI WAY	91326	12	216B109   373	2701084023	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	PIN	34.29188411	-118.58500462	12/26/2018 Changes to an approved set of plans. All changes have been clouded. Disconnect configuration has been revised for the battery back-up units.*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 14.95 kWdc/13.74 kWac-CEC and consists of (1) inverter, (46) modules, (1) load center, and (3) PowerWalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33600	14041-20000-25434	12611 N HENZIE PL	91344	12	219B133   123	2608026016	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.29989	-118.5115	PV1Central/String Inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 8kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(1) SolarEdge SE3000A-US-ZB-U transformerless inverter(41) SolarEdge P300 power optimizers(41) Trina Solar TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33601	17041-10001-07142	7301 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	33.94207	-118.423	"Change to approved set by adding new lighting fixture ""C"" and ""CE"". All changes under delta_1 only.(((T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM CAFETERIA TO OFFICE (TRAINING ROOMS). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2185 SQ. FT. B#17016-10000-04738)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33602	18041-20000-43744	20821 W SPRUCE CIR #59	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.29529	-118.58748	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33603	13041-10000-25944	920 W BLOOM WALK	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.01996	-118.28938	This is the replacement of old two 300kw and 300 kw , with 570kw, replacement of the MCC. 7 stories.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33604	15041-10002-01361	200 WORLD WAY TERM 2-ARRV  LEV1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM			PC Approved	03/31/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	changes to approved set by down sizing the main breaker from 200-Amp to 100-Amp. changes under delta 5 only, Univision, space 282.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33605	14041-10000-09799	2718 S ELLENDALE PL 1-6	90007	9	123B197  1480	5055013025	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.02977	-118.28859	nEW FIRE ALARM CENTRAL STATION, 3 STORY. 21 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33606	13041-10001-32250	3485 S ROSEWOOD AVE	90066	11	114B149   949	4244010018	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.00552	-118.44814	Expedited RSES plan check per applicant request.PV1, Install 4 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 16 modules Yingli YL250p-29b.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33607	19041-20000-12253	6935 N MURIETTA AVE	91405	2	183B153   764	2216013005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.19671	-118.43901	addition of (2) tesla ESS 5KW each to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33608	18041-10001-03229	11150 W SANTA MONICA BLVD 600	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	02-23-2018 Changes to an approved set of plan. Scope changed to reflect removal of lobby area from scope and revision to space from private to open office . T-24 forms revised. Changes has been clouded delta 2.THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33609	19041-10000-43177	15448 W SUTTON ST	91403	5	166-5A145 121	2283020008	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.15056	-118.47165	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION OF 34 MODULES (SOLARIA  POWERXT-360R-PD),  34 MICRO-INVERTERS (ENPHASE IQ7PLUS-72-2-US), AND 1 COMBINER BOX (ENPHASE)SYSTEM SIZE:  12.24 KW DC; 9.86 KW AC *MAIN SERVICE PANEL UPGRADE TO 200 AMPS UNDER SEPERATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33610	10041-20000-25349	8126 N VAN NUYS BLVD	91402	6	192B149   638	2212003015	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.21881	-118.44857	laundrymat 800 amps swichboard	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33611	18041-10000-32591	1438 W 254TH ST	90710	15	036B193   526	7410006044	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	33.79368	-118.30248	PV2. 2.1 KW ROOFMOUNTED SOLAR SYSTEM. + 13.5 KWH ENERGY STORAGE DEVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33612	19041-20000-23246	5130 E ALMADEN DR	90042	14	157-5A225 350	5479026006	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.1242	-118.20281	Plan check for PV and Energy Storage System, PV system size: 5.795KW, Energy storage system size: 27KWh, with 19 PV modules and 1 inverter(5.2KW) and 2 Tesla Power Wall 2.0.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33613	15041-10000-13233	1726 N NORTH SPRING ST	90012	1	136-5A219  47	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.06983	-118.2261	PC FOR POWER AND ENERGY. CHANGE OF USE FROM EXISTING WAREHOUSE TO OFFICE; CORE AND SHELL ONLY; TENANT IMPROVEMENT UNDER FUTURE PERMIT. TOTAL AREA 9961 SQ FT INCLUDES JUST TWO TENANT SPACES.B# 15016-10000-09082.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33614	18041-20000-40243	20703 W CHASE ST	91306	3	192B109   162	2780008034	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.22469	-118.58455	PV3.  Install 6.10 kW DC roof mounted grid tied PV system.  (20) modules with 5.0 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33615	17041-10002-24210	9301 N TAMPA AVE #212	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Supplemental PC for power and energy for changes to approved set to Dave and Busters restuarant. Scope includes removing and relocating equipment on the panel schedules, revising lighting circuit designations for terminations, and a 50A  2pole receptacle.  All changes are under delta 9.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33616	10041-10000-01725	777 E 10TH ST # 118	90021	9	124-5A211 244	5132002028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM	02/03/2010 12:00:00 AM		Permit Finaled	02/09/2010 12:00:00 AM	ADDRESS	34.03437	-118.24974	adding luminaires to retail space to be occupied by first time tenant ; total load supplied from tenant panelboard is less than was designed for	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33617	15041-20000-02769	12484 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33618	13041-10000-33094	1847 W 43RD ST	90062	8	114B193  1239	5022006011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.00561	-118.31298	PV1, ROOF-MOUNTED PHOTOVOLTAIC SYSTEM. 3.75 kW DC. Transformerless inveter with power (15) optimizers (Solaredge #OP250-LV-MC4SM-2NA-Z). (15) Trina solar #TSM-250PA05.18(1) Solaredge #SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33619	15041-20000-14204	1355 N GARDNER ST	90046	4	147B177  1280	5550024015	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			05/11/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.09593	-118.35301	Installation of new roof mounted solar PV array.  Total system size = 15.2 kWac. system uses 2 inverters. system is single phase 240v. total of 60 pv modules. solar clearance has been provided from building permit. this is net meter project. commercial rooftop of 18 unit apartment.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33620	11041-10000-27688	8158 W BEVERLY BLVD	90048	5	138B173   448	5511006031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.07591	-118.36736	New Fire alarm sytem	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33621	17041-20001-02930	6372 W SUNSET BLVD	90028	13	147A187   590	5546015043	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.09768	-118.32836	8/30/2017changes to an approved set of plans.  changes include new optional inverter for egress lighting only.  ((((Plan check for power and energy Change of use from Restaurant to Salon to existing Building Total load newly connected exceed 400A. Total indoor and outdoor area:21,861 sq ft. B#17016-10000-02002))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33622	16041-10001-01270	328 W 1ST ST	90731	15	018B201   661	7449023032	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.74343	-118.28412	2/19/2016CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE CHANGE FROM MAIN BREAKER TO FUSES AND LOAD ADDITION TO THE PV SUB PANEL. (((PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.6KW INTERCONNECTED WITH MSP.(19) KYOCERA 2656 MODULES(1) ABB 3.6KW INVERTER)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33623	18041-20001-04338	6857 W CAMROSE DR	90068	4	151-5A185 335	5549028031	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM			PC Approved	04/09/2018 12:00:00 AM	ADDRESS	34.10895	-118.33886	04-09-2018 Changes to an permitted set of plan. Changes include remove battery back up PowerWall. . Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33624	14041-20002-23765	17350 W LOS ALIMOS ST	91344	12	207B129   317	2696006002	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.26589	-118.51275	Modifications to approved set.  Upgrade of main service panel and main breaker.  PERMIT FEE IS $0.00 BY STATE SENATE BILL NO. 122(((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(56) KYOCERA KD 255 MODULES(1) FRONIUS INVERTER)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33625	14041-20000-33977	6206 N YARMOUTH AVE	91335	5	177B129   175	2123030013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	PIN	34.18264735	-118.51930343	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system.30  255W pv modules across 4 strings (6+6 combined and 9+9 combined).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33626	16041-10000-21250	20301 W CANTARA ST	91306	3	192B113   633	2107006026	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.21926	-118.57572	PV1 INSTALL NEW 7.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FMILY HOUSE.(30) MODULES: HYUNDAI HIS-S260RG 260W(30) MICROINVERTERS: ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33627	15041-20000-16280	936 S OLIVE ST UNIT 257	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #6 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33628	13041-20000-31244	7527 W WOODROW WILSON DR	90046	4	156B177   259	5570010008	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Expired	12/15/2015 12:00:00 AM	ADDRESS	34.12425	-118.3599	New rooftop UNGROUNDED PV Sytem for an existing single family dwelling.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33629	19041-10000-49986	4114 W SUNSET BLVD	90029	13	145-5A201 253	5429002005	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.09324	-118.28152	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 FOR 1ST AND 2ND FLOOR (INDOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33630	11041-20000-13380	10960 W WILSHIRE BLVD 1260	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM			PC Approved	06/28/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check T24 Energy (general/emergency) lighting for Tenant Improvement #1260. Permit under 11041-90000-12729	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33631	13041-20000-25513	5900 W WILSHIRE BLVD UNIT 720	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK UNIT 720	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33632	18041-10000-40648	2029 S CENTURY PARK EAST 22ND FLOOR-STE.2200	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT OF EXISTING OFFICE SPACE. TOTAL AREA: 5,814 SQ.FT(B# 18016-10000-30801)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33633	10041-10000-03840	20101 S HAMILTON AVE Bldg II-Suite 100	90502	15	054B197   127	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	09/10/2010 12:00:00 AM	ADDRESS	33.84769	-118.28637	REMODEL OFFICE SPACES -NEW OFFICES AND PARTITIONSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33634	16041-30000-18947	6060 W CENTER DR 5th Floor	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM			PC Approved	05/31/2016 12:00:00 AM	ADDRESS	33.97602	-118.39073	Plan check for Title 24 only. Project site is the 5th floor an existing commercial building. Project scope is a tenant improvement. Total lighting area = 21,070 sq. ft.Note: Building application has been created under 16016-10000-12328	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33635	18041-20000-08551	12301 W ROCHEDALE LANE	90049	11	138B141   252	4494008005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.07431	-118.48364	PV1.  Install 7.59 kW roof mounted grid tied PV system.  (23) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33636	18041-20000-06689	16625 W SATICOY ST	91406	6	186B137    12	2205009055	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.20857	-118.49579	replace existing lighting fixtures with new led.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33637	17041-20000-42001	2401-2413 W MARTIN LUTHER KING, JR BLVD	90008	10	114B189   315	5034018001	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.01095	-118.31959	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 600 AMPS DUE TO FIRE DAMAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33638	16041-20001-21765	17725 W LEMARSH ST	91325	12	204B129   232	2734001015	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.25599	-118.52076	EXPEDITEPV1ADDITION TO EXISTING SYSTEM.  ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33639	12041-10000-05197	100 E 47TH ST	90011	9	112-5A205 366	5109002049	C2-1VL	South Los Angeles	Southeast Los Angeles			2293.00, 2319.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.00091	-118.27364	TITLE 24 PLAN CHK FOR AN OPEN PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33640	12041-20000-14489	20112 W LANARK ST	91306	3	189B113   105	2107016113	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.21789	-118.57162	Roof mounted P.V. system (16.9 KWdc) with microinverter with service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33641	16041-20000-37424	10435 N GAVIOTA AVE	91344	12	207B141   840	2668020030	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.26031	-118.48278	pv1install roof mounted pv system sized 8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33642	16041-20001-11402	18334 W MALDEN ST	91325	12	192B125   203	2786007004	(T)(Q)R3-1, R1-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Apartment			08/22/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	PIN	34.22512205	-118.53292311	"Revisions to approved set.  Review and approval for delta E2 and E3 revisions only.  Service location change, additional house panel R, and insertion of gym and recreation rooms.  (((PROPOSED 22-UNIT  4-STORY APT.  BLDG.,  WITH 1-LEVEL SUBTER. PRIVATE PKG.  GARAGE.""2-VERY LOW INCOM UNITS.""                                                                                                                                PC FOR POWER AND ENERGY. DUE TO BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 ENERGY STANDARDS.F.A variance is submitted on 4/1/16)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33643	16041-10001-05064	5050 N CHICOPEE AVE	91316	5	171B129   356	2257018026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM			PC Approved	06/17/2016 12:00:00 AM	ADDRESS	34.1628	-118.51222	EXPEDITED FEES(((PV1, SOLAR ROOF MOUNTED SYSTEM USING CENTRAL INVERTERS. (62) MODULES AND (3 - 7.7KW) INVERTERS. TOTAL SIZE 23.1 KW.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33644	13041-10000-04748	13700 W CHANDLER BLVD	91401	2	171B157   133	2247016001	RA-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00, 1286.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	34.16822	-118.43179	PV1 22.08KW ROOFMOUNT. 2STORY. MOD:92 TRINA TSM-240PA05. FRONIUS IG PLUS V 10 & 7.5. 2 COMBINERS AND 7 STRINGS. EXISTING 800A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33645	19041-20000-29703	7900 N BALBOA BLVD BLDG E	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	06/07/2022 12:00:00 AM	ADDRESS	34.21347	-118.50092	"New 2-story commercial office addition connected to aircraft hangar building ""E"".  Service equipment permitted under 18041-20000-31255.  Plan check for power and energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33646	13041-20000-11254	101 S LA BREA AVE	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.07338	-118.34425	FULL PLAN CHECK FOR RENOVATION OF EXISTING 2 STORY OFFICE BUILDING. TOTAL NEW CONNECTED LOAD EXCEEDS 400A. Changes to plans during verification.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33647	13041-20000-12668	641 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	33.8928	-118.28657	New restaurant. 600 amp new service, new panels, and ckts. EPC is for power & energy.  Site is in a Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33648	19041-20001-20173	2049 S CENTURY PARK EAST 38th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. REMOVAL OF OFFICE AREA AND EXPANSION OF LUNCH ROOM. CHANGES MADE TO FLOOR PLAN, PHOTOMETRICS, AND T24 SHEETS. CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33649	19041-20000-49765	2520 N LAKE VIEW AVE	90039	13	148-5A209  90	5438008027	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			Reviewed by Supervisor	12/12/2019 12:00:00 AM	ADDRESS	34.10277	-118.25457	Plan check for Solar Voltaic Roof  Tiles (Solar Glass) and Energy Storage System, Solar Voltaic system size: 5.96KW with 102 Solar Voltaic Roof Tiles and 1 inverter(5.2KW) and 2 Battery(Tesla Power Wall 2.0)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33650	15041-10002-24845	2407-2419 E 1ST ST	90033	14	127-5A223 164	5180002016	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.04369	-118.20936	Changes to approved set of plans. updated dwelling unit numbers and updated size of elevator motor. changes noted delta 3 on plans. PC only. permit issued under master	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33651	19041-10000-06132	5250 N LOLETA AVE	90041	14	163-5A227 154	5691001018	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.14275	-118.198	NEW ROOF MOUNTED 9.75 KW PV SYSTEM WITH 30 PV PANELS ON A SINGLE FAMILY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33652	19041-20000-34850	21240 W BURBANK BLVD	91367	3	174B105    91	2149016028	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.17307	-118.59314	POWER PLAN CHECK FOR INSTALLATION OF A NEW 1600A SWITCHBOARD AND AUTOMATIC TRANSFER SWITCHES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33653	17041-20000-15660	16852 W KNOLLWOOD DR	91344	12	216B137   534	2610016020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Issued	05/10/2017 12:00:00 AM	ADDRESS	34.28469	-118.49856	pv1install roof mounted pv system sized 6.6kw interconnected with msp.  standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33654	17041-20001-01475	13039 W ADDISON ST	91423	4	171B161   976	2358026022	RE15-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.16136	-118.41718	expedite per applicantpv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33655	18041-20000-19211	10101 W ROSSBURY PL	90064	5	123B165   380	4316016017	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.03477	-118.40412	Plan check for PV roof mounted system, System size: 11.055 kWac with 33 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33656	15041-20001-07098	20407 W ROMAR ST	91311	12	204B113   386	2741006021	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			Reviewed by Supervisor	03/20/2015 12:00:00 AM	ADDRESS	34.25471	-118.57755	Expedite per applicant request. ((Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (20) modules and (1) inverter. Standard plan is not being used and was submitted per applicant request.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33657	11041-20000-04384	1901 S AVENUE OF THE STARS SUITE 1900	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	06/15/2011 12:00:00 AM	ADDRESS	34.05949	-118.41705	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT IN (E) OFFICE SPACE (SUITE 1900)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33658	19041-20000-28980	8360 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Issued	08/19/2019 12:00:00 AM				new sfd 800 amp service.  plan check for power only.permit fees paid under building combo permit 18010-20000-05049.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33659	12041-10000-04219	1719 S HOBART BLVD	90006	10	126B193   528	5074018016	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.04207	-118.30545	(22) PV SOLAR PANELS ON SFD ROOF. Solar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.(*NOTE* Express permit was previously issued under PCIS 11041-10000-26809;Supplement fees for the difference)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33660	16041-10000-14377	2814 S HAUSER BLVD	90016	10	120B177   256	5043020014	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.02815	-118.3642	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(12)MODULES-SUNPOWER 327W SPR-327NE-WHT-D (1)INVERTER-SMA 3.8 SB3800TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33661	14041-20000-25899	11101 S LA CIENEGA BLVD	90045	11	087B173    55	4129038025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	33.93379	-118.37023	TI TO AN EXISTING ONE STORY COMMERCIAL BUILDING.  ADDING LIGHTING AND CIRCUITS. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33662	17041-10000-10458	555 S MATEO ST Bldg 2-Ste 300	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.03943	-118.23302	PC FOR POWER AND ENERGY FOR FIRST TIME TENANT.OFFICE SPACE IN COMMERCIAL BLDG. TOTAL AFFECTED AREA 67260 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33663	11041-10000-14598	6434 W INNSDALE DR	90068	4	159B185   137	5577038020	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.12986	-118.33045	NEW PV SYSTEM FOR SINGLE FAMILY DWELLING WITH TWO INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33664	18041-10000-19312	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	33.97811	-118.39245	Tenant improvement to existing (StarBucks) Restaurant and outside dining area.Plan Check for T-24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33665	11041-20000-02797	600 W WILSHIRE BLVD #1000,1050	90017	9	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	34.04796	-118.25622	energy plan check suite 1000 & 1050	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33666	18041-20000-48290	3809 S GRAND VIEW BLVD	90066	11	114B157  1475	4235023001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Info Complete	12/20/2018 12:00:00 AM	ADDRESS	34.00441	-118.43106	Plan check for Title 24 only. Project site is an existing restaurant. Project scope is an expansion and tenant improvement. Total lighting area = 1,509 sq. ft.Note: Building application has been generated under 18016-10000-26894	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33667	18041-20000-32856	4331 W ADAMS BLVD	90018	10	123B185   680	5059005031	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.02	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.03275	-118.33307	Renovation of (E) commercial kitchen and eatery.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33668	13041-10000-05585	15718 W MILBANK ST	91436	5	168B141   529	2261009002	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2013 12:00:00 AM			Plans on Hold	03/05/2013 12:00:00 AM	ADDRESS	34.15695	-118.47574	ON HOLD - APPLICANT WILL APPLY FOR REFUND.   ------    PV1 ROOF MOUNTED SOLAR INSTALLATION IN SINGLE FAMILY RESIDENCE. SYSTEM SIZE IS 7.2 KW DC. USING 31 MODULES WITH TWO INVERTERS AND 3 STRINGS. [MODULES: SOLARWORLD # SW240 POLY |||| INVERTERS: POWERONE # PVI-3.8-1-OUTD-S-US 240 AND FRONIUS # IG-PLUS 3.0]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33669	16041-20002-08861	15303 W VENTURA BLVD SPACE P10	91403	4	168B145   821	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM			PC Approved	01/12/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	Original approved plans lost at job site - recheck of electrical drawings - T-24 Part 6 plan check only.  (((T-24, PC for energy only. TI on (E) Restaurant inside the Sherman Oaks Galleria - SPACE P-10. Total area: 2,691 sq. ft)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33670	17041-20000-45351	2026 W OLYMPIC BLVD #A	90006	1	130-5A203 211	5136012026	C2-1	Central	Westlake	Pico Union		2095.20	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.05132	-118.27946	Plan check for energy only. TI/Convert portion of (E) office to (N) retail store. New lighting (incl. emergency) - 300sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33671	18041-20000-17731	5210 N LA RODA AVE	90041	14	163-5A225 210	5669019011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Expired	10/01/2023 12:00:00 AM	ADDRESS	34.14182	-118.20472	Plan check for PV roof mounted system. System size: 9.0kWac with 36 modules and 2 inverters(3.0 and 6.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33672	12041-10000-27930	5960 N SEPULVEDA BLVD	91411	4	177B145   497	2243019026	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Info Complete	01/23/2013 12:00:00 AM	ADDRESS	34.17803	-118.46469	PLAN CHECK FOR TITLE 24 ENERGY OVER 30000 SQ FT. 44086 SQ FT TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33673	17041-30000-15488	2134 W SUNSET BLVD A	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.07723	-118.26485	Plan check for power and energy. Project site is a suite within an existing commercial building. Project scope is a first time tenant. Total lighting area = 1,845 sq. ft.Note: Building application has been generated under 17016-30000-07986	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33674	13041-10001-24715	14722 W MAGNOLIA BLVD UNIT 1	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33675	16041-10000-36154	933 S HOOVER ST	90006	1	132A201   312	5076006001	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.05447	-118.28438	TITLE 24 ONLY FOR EXISTING OUTDOOR COMMERCIAL BUILDING. REMOVAL OF EXISTING HID FIXTURES WITH NEW LED FIXTURES. TOTAL SQ. FT. 5890	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33676	11041-20000-20156	12181 W BLUFF CREEK DR 1ST FLR	90094	11	102B161  1150	4211010096	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	33.97788	-118.40638	T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE SUITE TI. PERMIT FOR ELECTRICAL WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33677	14041-20000-05984	13553 W PIERCE ST	91331	7	204B157   498	2646010014	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.25662	-118.42803	Roof mounted PV system with tranformerless, system size is 5.8KWdc.Note: Permit includes upgrade service panel to 200A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33678	14041-20000-25167	461 W 9TH ST	90731	15	015B201   382	7455008002	C2-1VL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			PC Approved	09/12/2014 12:00:00 AM	ADDRESS	33.73592	-118.28701	Plan check for energy only. New lights added to supplement existing lighting system in existing auditorium of a charter school. No new emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33679	18041-10000-10653	1019 W ROBIDOUX ST	90744	15	033B201   207	7415015030	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	33.78796	-118.27542	Plan check for PV roof mouned battery back  system. System size: 7.6kW with 9.8kWh LG battery and 29 modules and 1 inverter(7.6kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33680	15041-20002-39933	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			PC Approved	10/25/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	"10/23/17changes to an approved set of plans.  changes noted delta 6.  changes include the addition of 16 EV chargers to house meter ""MMH"" and relocating panels HP and LP with no change in connected load.  This is plan check only.    (((((Full PC for new warehouse shell only, Scope includes New Xformer, elec.room, house panels and site lighting.2000 MSA, total area: 255,181sq.ft (uncondition+hardscape))))))((WHSE SHELL))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33681	19041-10000-12581	1120 S GRAND AVE #1123	90015	14	126A207    60	5139020094	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.04095	-118.26231	FULL PLAN CHECK  FOR A FIRST TIME TENANT (FITNESS CENTER) IN A HIGHRISE. SCOPE INCLUDES NEW TRANSFORMER (112.5KVA),  2 NEW PANELS( 400A AND 100A), LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3092 SQ.FTB#19041-10000-09044	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33682	14041-20001-00048	2377 N WEST SILVER LAKE DR	90039	4	148-5A207  32	5439028006	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.1031	-118.26668	(((Plans lost. Verifying nothing changed for a restamp)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33683	18041-10000-45085	3408 E EMERY ST	90023	14	117A225   161	5192014007	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	01/20/2021 12:00:00 AM	ADDRESS	34.0153	-118.20646	SERVICE UPGRADE TO 800 AMPS. CORE AND SHELL ONLY. POWER & ENERGY FOR CORRIDOR.FUTURE TI'S WILL REQUIRE COMPLETE PLAN CHECK.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33684	09041-10002-24074	600 W WORLD WAY TERMINAL 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Info Complete	04/05/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	TERMINAL 6  RENOVATIONS-  RELOCATING ALASKA AIRLINES OFFICES TO  NEW AREAS  ; REMODEL BAGGAGE HANDLING AREA  WHICH IS AWAY FROM THE PASSAGENER AREA(((    Changes made to prviously approved set.((((((((((((((((((((((((((((((((((((((   changes made to previously approved set, complete titl24, 120 new revised and or added circuit, and one panel , ))))))))))))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33685	12041-20000-13066	3900 N STANSBURY AVE	91423	4	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1417.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	ADDRESS	34.14084	-118.44264	Convert classroom to food service area.   New additional electrical load approx. 133A.   Install general/emergency lightings.  Plan check for energy only.Note: Permit issued under 12041-20000-13071	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33686	19041-10000-23236	962 N MALTMAN AVE	90026	13	142-5A203 120	5427022003	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.08598	-118.27953	(ePlan) PV1. REVISION TO 19041-10000-18786; Delta B changes to reduce the inverter size from a 7600W to 6000W.  Delta A changes for relocating service panel and inverter was approved under 19041-10000-22116	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33687	13041-20003-25070	19332-19334 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.23457	-118.55484	Modification to previously approved set of plans to change one feeder size.        <<<INSTALLING TWO 400A SECTIONS TO NEW 800A SERVICE. RUNNING CONDUITS WITH CONDUCTORS TO SHELL BUILDING. NO LOAD IS TO BE ADDED AT THIS TIME. THE FUTURE TENANT REQUIRES FULL PLAN CHECK.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33688	17041-10001-21811	659 S BROADWAY 10TH FLOOR	90014	14	129A211   258	5144003040	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Approved	07/13/2017 12:00:00 AM	ADDRESS	34.04551	-118.2533	Plan check for Title 24 only in existing space highrise building on 10th floor bath room. Total area: 1280 sq ft.Note: plan check only, permit was pulled under orginal application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33689	14041-20000-06174	5522 N BLANCO AVE	91367	3	174B089   525	2046013013	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.17102	-118.65229	pv1 single family dwelling. total system size 4.3kw AC using microinverter enphase m215. using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33690	18041-20000-41355	5400 W ADAMS BLVD	90016	10	123B177  1043	5043008022	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.03231	-118.36065	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant. Total lighting area = 1,538 sq. ft.Note: Building application has been generated under 18016-30000-25864	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33691	16041-10000-40190	419 S SPRING ST	90013	14	129A211    54	5149024027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Closed	09/19/2019 12:00:00 AM	ADDRESS	34.04843	-118.24885	PLAN CHECK FOR FIRE ALARM SYSTEM - CORE AND SHELL ONLY FOR 13 STORY COMMERCIAL BULDING.SYSTEM SIZE: 98 FIRE ALAM DEVICES, AND 2 FIRE ALAM PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33692	15041-20001-18919	10933 W ROCHESTER AVE SYSTEM 2	90024	5	132B153   743	4324005087	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.05602	-118.4436	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 24  KW. (80) 310W MODULES(3) SMA SB77000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33693	10041-10000-15991	13075 W BLAIRWOOD DR	91604	5	162B161   482	2385016027	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	34.14043	-118.41745	ROOF INSTALLATION OF 17.8KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33694	14041-20000-03086	18425 W BURBANK BLVD Suite 520	91356	3	174B125   370	2160001023	C2-1L, C4-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.17242	-118.53474	T24 FOR EXISTING OFFICE. ALL LIGHTS AND RECEPTACLES ARE EXISTING ONLY DOING CHANGES TO THE CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33695	12041-20001-03026	2910 W BEVERLY BLVD ROOF Level	90057	13	138A201   357	5155004023	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.07099	-118.28068	added 14 devices to roof of previously approved plan. fire alarm replacement low rise building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33696	17041-20000-12156	12820 W DELANO ST	91606	2	177B161   535	2332031009	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	PIN	34.1820465	-118.41243338	PV1. ROOFMOUNTED SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 5.9 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33697	18041-10000-07882	5254 N DENNY AVE	91601	2	171B177   406	2416025001	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			03/05/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Closed	02/24/2021 12:00:00 AM	ADDRESS	34.16646	-118.36414	FULL PLAN CHECK FOR (N) 3-STORY W/ MEZZANINE   8-UNIT APARTMENT BUILDING OVER ONE BASEMENT GARAGE . SCOPE INCLUDES A  600A, 120/240V, 3P SERVICE. TOTAL COMMON AREA 6,490 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33698	13041-10000-13104	928 N WESTERN AVE 1-49	90029	13	144B193  1289	5535020018	(Q)RAS3-1VL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Public Safety Only			05/20/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.08731	-118.30896	NEW FIRE WARNING  SYSTEM FOR A 5-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33699	16041-20001-00115	5187 E BORLAND ROAD	90032	14	138A235   256	5221003018	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	34.07181	-118.17133	Revisions to approved plans.  Rooftop module layout change and reduction of (1) module from project scope.  (((PV1, rooftop solar installation 3kW AC(12) KU2656ZPA(1) PVI-3.0-OUTD-S-US)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33700	15041-10000-34615	5800 S SAN PEDRO ST	90011	9	108B205  1081	5101007002	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	33.98962	-118.26998	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33701	17041-10002-24569	18620 W VENTURA BLVD	91356	3	174B121   644	2161015013	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM			PC Approved	08/20/2018 12:00:00 AM	ADDRESS	34.16987	-118.53933	"08/14/2018CHANGES TO AN APPROVED SET OF PLANS, CHANGES NOTED UNDER DELTA 3A. CHANGES INCLUDE THE ADDITION OF A 1200AMP MCB ON THE SECONDARY OF THE TRANSFORMER IN PLACE OF THE SECONDARY DISCONNECT. [[6/29/18 CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA ""3"" CHANGES. ISTALLATION OF A 500KVA TRANSFORMER BETWEEN MAIN SWITCHGEAR AND DP1 ]]] PC power and energy for LA fitness TI. PC includes new 1600A service, three new panels, new circuits and equipment. Total affected area is 24536 sqft. Building # 17016-10000-16949."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33702	14041-10000-28275	6245 W FOOTHILL BLVD	91214	7	198B205   184	2571006024	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Closed	02/16/2017 12:00:00 AM	PIN	34.24147771	-118.26708506	PC FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR BIG 5 SPORTING GOODS; TOTAL AREA  10600 SQ FT.B# 14016-10000-20782	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33703	11041-20000-17001	8401 N VAN NUYS BLVD #26	91402	7	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	01/09/2012 12:00:00 AM	ADDRESS	34.22308	-118.44896	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO DENTAL OFFICE. NEW LIGHT FIXTURES ON EXISTING LIGHTING CKTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33704	14041-10000-10771	4144 1/2 S SOMERS AVE	90065	14	157-5A217 170	5459025023	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	Apartment			04/24/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.12617	-118.23298	Install roof mounted solar array interconnect with main panelSystem size = 2.253 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33705	14041-10000-03754	1227 N HIGHLAND AVE	90038	4	144B185   343	5532006007	C2-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.09331	-118.33882	new sprinkler monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33706	14041-10000-12031	1149 S HILL ST # 425 &-# 450	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.03926	-118.26099	permit to be pulled at EPC counter only. Plan check for energy only. Emergency lighting in a highrise building. Less than 400A per applicant but other work is being done in the building under separate projects. BLDG#14016-10-07126: NON-STRUCTURAL T.I.; TWO SUITES.  NEW PARTITIONS.  SUSPENDED CEILING.  SUITE 425:  2,278 SQ.FT.; SUITE 450: 3,534 SQ.FT.; TOTAL 5,812 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33707	13041-10000-04571	10476 W KINNARD AVE	90024	5	132B157   472	4326030008	R1-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Closed	06/06/2013 12:00:00 AM	ADDRESS	34.05863	-118.42746	PV1 FOR 2 STORY HOUSE.  5.18 KW {ENPHASE MICROINVERTER M215-60-2LL-S22} {24 MODULES: MONO X LG255S1C-G3}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33708	14041-20001-05728	9719 W MUSTANG WAY	91040	7	204B181   124	2549025033	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.25851	-118.34341	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. USING SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33709	13041-10001-26295	15451 W SUPERIOR ST	91343	7	201B145   461	2656004029	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.24654	-118.46932	][][][EXPEDITED PER APPLICANT REQUEST][][][PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 225A MAIN; WORK DONE ON A STANDARD PLAN. 4 TOTAL STRINGS; COMBINER BOX WILL BE USED; SYSTEM SIZE IS 12KW DC WITH (48) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG PLUS V 11.4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33710	10041-10000-08141	1900 S AVENUE OF THE STARS 9TH FLOOR	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	05/21/2010 12:00:00 AM		Permit Finaled	08/09/2010 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI IN AN EXISTING OFFICE AREA ON THE 9TH FLOOR. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33711	17041-10001-20922	5748 N IRVINE AVE	91601	2	174B169   373	2338019015	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.1753	-118.38541	expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33712	12041-10000-23428	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			10/02/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.03396	-118.24117	PLAN CHECK POWER AND ENERGY FOR NEW BUSINESS OCCUPANCY/TENANT IMPROVEMENT ON FLOORS 3 AND 4. NEW SERVICE PLAN CHECK UNDER #12041-10000-10792. EXISTING BUILDING 4-STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33713	19041-20000-21366	9763 N ABREGO CT LOT 11	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.24774	-118.45068	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33714	15041-10000-38603	5760 W ARBOR VITAE ST	90045	11	093B169    79	4125020014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Issued	11/24/2015 12:00:00 AM	ADDRESS	33.9525	-118.38238	FA SYSTEM. REPLACEMENT AND UPGRADE OF EXISTING. TOTAL OF 140 DEVICES AND NEW CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33715	19041-10000-49006	2029 S CENTURY PARK EAST 1ST FLR	90067	5	132B161   697	4319016029		West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	05/04/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INLUCDES NEW LIGHTING AND RECEPTACLES LOADS. TOTAL SQ. FT. 10825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33716	15041-20002-12115	11507 W OXNARD ST #5	91606	2	177B169   797	2338004012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.1796	-118.38271	10/19/2015 Changes to an approved set of plans. Changes reflect the additional equipement installed on the field (water heaters). *****Previous Work Description*****CHG OF USE FROM OFFICE TO MEDICAL OFFICE AT 2ND FLOOR; pc for power and energy. per art 517 health care. new lights, power and patient rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33717	12041-10000-12957	5600 N VAN NUYS BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM	ADDRESS	34.17244	-118.44837	TENANT IMPROVEMENT IN EXISTING RETAIL SPACE-RETAIL VERIZON STORE-UNIT 5604 PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33718	11041-10000-05904	145 S SPRING ST 6TH Floor	90012	14	130-5A213  30	5149001003	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Info Complete	03/25/2011 12:00:00 AM	ADDRESS	34.05196	-118.24563	"TI IN AN EXISTING COMMERCIAL AREA ON THE 6TH FLOOR OF LA TIMES BUILDING.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS ONLY.  COMPLETE ""EPC"" MAY BE REQUIRED SUBJECT TO FIELD INSPECTION.  SEPERATE FIRE ALARM PERMIT ISSUED BY OTHERS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33719	13041-20000-07275	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			Corrections Issued	09/24/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Change of use, Retail to  Beauty Parlor.  Interior Remodel.  Full Plan Check requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33720	17041-10000-36303	7827 N CANTALOUPE AVE	91402	6	189B157   688	2214014002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.2129	-118.43156	PV ROOF MOUNTED SYSTEM USING CENTRAL INVERTER. (1) 3.0KW INVERTER AND 8 MODULES. TOTAL SYSTEM SIZE IS 3KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33721	19041-10001-20165	17048 W GRESHAM ST	91325	12	195B133   402	2690010013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	34.22959	-118.50432	DELTA 1 Changes to an approved set to show on the plans the PV performance meter required by DWP and the existing 400A service panel with split bus.Original Scope: PV1, PC FOR NEW ROOFTOP 10.4 KW SYSTEM. SYSTEM CONSISTS OF 32 MODULES(PANASONIC VBHN325KA03) WITH 32 OPTIMIZERS (SOLAREDGE P400). 1 CENTRAL INVERTER(SOLAREDGE SE1000H-US).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33722	19041-10000-44106	2500 S NAVY WAY P 400	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	05/11/2022 12:00:00 AM		Issued	05/11/2022 12:00:00 AM	ADDRESS	33.73363	-118.2408	POWER PLAN CHECK FOR RELOCATION OF TWO EXISTING DWP SERVICES OF 600Amp EACH, EXISTING LIGHT POLES AND ADDITION OF NEW LIGHT POLES AND PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33723	16041-10000-18186	10100 W SANTA MONICA BLVD 4th,9-10th-& 25th flr	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	34.06191	-118.41691	PC FOR ENERGY. HIGHRISE BUILDING . SCOPE OF WORK ON 4TH, 9TH, 10TH AND 25TH FLOORS CORRIDORS AND LOBBIES. TOTAL AREA 5960 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33724	17041-10000-00230	846 E 6TH ST	90021	14	126A213   286	5147030020	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.0398	-118.24168	Plan check for power only  service upgrade 600 A.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33725	18041-10000-46476	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.14436	-118.27496	PLAN CHECK FOR POWER ONLY FOR - BLOOM ENERGY FUEL CELL EQUIPMENT AND WIRING FOR CONNECTION TO EXISTING DISTRIBUTION SYSTEM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33726	17041-10000-21334	5700 W WILSHIRE BLVD 4TH FLR	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM			PC Info Complete	07/20/2017 12:00:00 AM	ADDRESS	34.06218	-118.35303	PC FOR OFFICE TI. TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 607 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33727	14041-20000-12254	444 S FLOWER ST 10TH FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLANCHECK FOR T24 ENERGY. CORRIDORS AND RESTROOMS ON 10TH FLOOR. HIGH RISE. 2055 SQFT, EMERGENCY LIGHTING. ALL WORK TO BE INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33728	19041-20000-12457	20928 W ITASCA ST	91311	12	201B109   297	2746007011	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			PC Info Complete	09/30/2019 12:00:00 AM	ADDRESS	34.24467	-118.58965	Power, lighting, and distribution for commercial auto repair garage.  Hazardous location plan review per Article 511.  Plan check for power and energy.  B#18014-20000-03176	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33729	14041-20000-27556	7318 N MASON AVE	91306	3	186B109   864	2114016004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Expired	10/31/2016 12:00:00 AM	ADDRESS	34.20361	-118.57956	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(24) SolarEdge P300 power optimizers(24) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33730	17041-30000-40706	11601 W WILSHIRE BLVD 17th Floor	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 only in exist space office T.I. small portion of the floor is being alter corridor and small offices. Total area: 440 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33731	14041-20001-08100	10221 N VALJEAN AVE	91343	12	204B137   454	2678004029	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.25621	-118.48725	Modification to approved set.  Relocation of inverter to wall by main service panel and corresponding removal of disconnect switch.  PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33732	13041-20000-18630	601 S FIGUEROA ST 19TH FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	T24 FOR EXISTING LOBBY/CORRIDOOR FOR HIGHRISE BUILDING ON THE 19TH FLOOR. TOTAL SQRFT 1850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33733	19041-10000-04651	10250 W SANTA MONICA BLVD # 1610	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Issued	03/01/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	first tenant in commercial space at a mall-Bibigo RESTAURANTFULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33734	15041-10000-26353	335 W 31ST ST STE A	90007	9	120A203   127	5122018021	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.0231	-118.27594	PC FOR T-24. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33735	18041-10000-26187	9265 N BORDEN AVE	91352	6	198B173    92	2408039014	M2-1-CUGU, [Q]M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.23721	-118.36884	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33736	18041-10000-06888	1637 E 103RD ST SUITE  A	90002	15	091-5A213 142	6048013053	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	33.94431	-118.24513	CHANGE OF USE OF PORTION OF RETAIL TO DENTAL OFFICEFULL PLAN CHECKREF.: 18016-10000-01986	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33737	17041-10000-41902	617 W 7TH ST 1104	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.04779	-118.2571	TITLE 24 PLAN CHEK FOR - OFFICE TI TO EXISTING VACANT SUITE - NO NEW EQUPTMENT WAS ADDED TO DISTRIBUTION EQUIPMENT. TOTAL AFFECTED AREA = 2829 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33738	17041-10000-35242	5670 W WILSHIRE BLVD 9TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	PC for T24 only for Ti for screening room in film studio. Installing new lights, receptacles and equipment. Building# 17016-10002-12011. Total area 711sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33739	13041-10000-28350	10473 W SANTA MONICA BLVD	90024	5	132B157   811	4326032015	(Q)RAS4-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			10/11/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	PIN	34.05618193	-118.42669161	NEW 24 UNIT 5 STORY APARTMENT WITH GARAGE PKG. NEW 1200 AMP SERVICE 120/240 V.[][][conduit-only variance filed on 1/7/2014 under pc#14041-10000-00416 ][][][	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33740	13041-10001-35744	8700 W BEVERLY BLVD 1F	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	09/10/2014 12:00:00 AM	ADDRESS	34.07666	-118.3805	[[[[9/10/14  CHANGES TO APPROVED SET OF PLANS. DELTA 2 CHANGES ONLY. CREATION OF AN OFFICE ON THE GROUND FLOOR. ADDITION OF FEW RECPETACLES AND LIGHTING.]]]]]TI 1ST FLOOR. PC for POWER ENERGY GAMMA KNIFE TO MRI. adding 2 UPS as well. Plan checker to verify fees ***ARCHITECTURAL & STRUCTURAL ALTERATION AT THE FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33741	17041-20000-03361	12922 W VICTORY BLVD	91606	2	180B161  1114	2331012001	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.18651	-118.41485	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR MEDICAL OFFICE. 1728 SQFT.Building permit filed under 17016-20000-00429	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33742	16041-30000-10005	1641 S CRESCENT PL	90291	11	108B145  1270	4241013013	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	33.99104	-118.4615	Installation of new roof mounted solar PV array on existing duplex.  Total system size = 3 kWac.  Microinverter system.  Address was not available for online permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33743	15041-20000-04722	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	(T)(Q)M2-1, MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for power. New large furnace infrastructure. Emergency lighting conversion to 24 hour nightlight operation. Installation of new substation. Medium Voltage 4160/480 1000 kVA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33744	18041-10000-34717	601 S FIGUEROA ST 26TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT TO 26TH FLOOR INCLUDING ADDITIONAL PARTITIONS, NEW LIGHTS AND RECEPTCALE, TOTAL AREA: 4,700 SQ.FT( B# 18016-10000-28956)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33745	16041-20002-08117	3664 N WILLOW CREST AVE	91604	2	159B173    37	2380006006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.13615	-118.36756	[[6/14/16 CHANGES TO APPROVED SET.  ADDITION OF 5 MODULES AND UPGRADING INVERTER TO SE7600]]]$0 permit fee due to State Senate Bill SB-1222. Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33746	13041-20002-23194	9301 N TAMPA AVE # 67	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	(((2/25/2014- CHANGES MADE TO APPROVED SET OF PLANS. PLAN CHECK FOR ENERGY ONLY.)))) TI retail space in mall.  Power and energyNote: this should be Title 24 only plan check-remodeling existing retail store ;added power load is less than 100A; CONDUCTORS, PANELBOARDS AND MAIN SWITCH ARE EXISTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33747	16041-30000-23417	19242 W DUNURE PL	91326	12	219A119   226	2820009011	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.29277	-118.55298	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33748	19041-10000-46996	111 E UNIVERSAL HOLLYWOOD DR 16TH;20TH-25TH FLRS	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00, 3200.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.13855	-118.36112	ALTERATIONS IN RESTROOMS ON THE 16TH; 20TH; 25TH FLOORS OF OFFICE BUILDINGPLAN CHECKIS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33749	16041-10000-16664	11766 W WILSHIRE BLVD 7th floor-CORRIDOR	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.04804	-118.46227	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 7TH FLOOR CORRIDOR SPACE. SCOPE I1492 UDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1492 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33750	14041-20000-35186	879 W 190TH ST 4TH FLR	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	33.85951	-118.28963	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS AND CIRCUITS.  SCOPE OF WORK TO BE PERFORMED IN THE 4TH FLOOR.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 7950.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33751	15041-20000-07016	11255 N ILEX AVE	91331	7	210B153   277	2616020012	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.27436	-118.43318	CHANGE SERVICE. NEW 600A SERVICE TO SUBFEED 3 TENANTS. NO LOADS AT THIS TIME. CALCULATE GENERAL LIGHTING LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33752	13041-10000-14142	8400 W 3RD ST	90048	5	138B173   825	5511032046	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.0729	-118.37336	Retail TI, single-story building, 1151 sq ft.  Newly connected load < 400 A.  Title 24 plan check only. The application is associated with both plan check and for permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33753	13041-20000-19359	6623 N CRANER AVE	91606	2	180B173   407	2414027030	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.19098	-118.36936	PV1 MICROINVERTER 2.16 KW. 10 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33754	16041-10000-12066	5015 N EAGLE ROCK BLVD	90041	14	162A221   218	5686021030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.13746	-118.21479	FUL PC FOR POWER AND ENERGY. INTERIOR TI FOR EXISTING  3 STORY OFFICE BUILDING; WORK INCLUDE change of use of one of the office tenant space at ground floor to restaurant with new mezzanine inside (Core and shell only with tenant 301). SCOPE INCLUDES 4 NEW 75KVA TRANSFORMERS,  AND 15 NEW SUBPANELS FOR TENANT SPACES. TOTAL AFFECTED AREA IS 7057 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33755	18041-10000-42727	6420 W WILSHIRE BLVD #1520	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I. TO EXISTING OFFICE AREA IN SUITE # 1520. T-24 ENERGY ONLY. 1565 SQR FT.BULDING PERMIT: 18016-10000-35414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33756	15041-10001-27110	12452 W OSPREY LANE Unit #3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	PV2 installed roof mounted pv system  for UNIT #3. Size 3KW, interconnected with the main service panel.(8)modules: SPR-230NE-BLK-D(1)PVI 3.0-OUTD-S-US inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33757	17041-20001-37881	23412 W MAESTRO PL	91304	12	186B093    53	2027001032	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			PC Approved	11/16/2017 12:00:00 AM	ADDRESS	34.20975	-118.63895	expeditepv1install roof mounted pv system sized 6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33758	19041-20000-48424	10703 W COLEBROOK ST	91040	7	204B177   270	2542012013	(Q)RE20-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.25247	-118.36276	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 11.34 KW DC/11.4 KW AC. SCOPE OF WORK CONSISTS OF (36) PV MODULES, NEW LOAD CENTER, 3.8 KW INVERTER, AND A 7.6 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33759	13041-10000-36323	449 S BROADWAY 1ST FLR	90013	14	129A211    56	5149026001	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Info Complete	07/25/2014 12:00:00 AM	ADDRESS	34.04848	-118.25056	CHANGE OF USE FROM CAFE TO BANK (2895 SQ. FT.).  INTERIOR NEW TI IN HIGH-RISE BUILDING; EMERGENCY LIGHTING TO BE INCLUDED IN SCOPE OF WORK. PLAN CHECK FOR POWER AND ENERGY PER APPLICANT REQUEST. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 2,667 SQ FT USING TAILOR METHOD COMPLIANCE. BUILDING PERMIT: 13016-10000-25603	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33760	17041-10000-29401	6301 W 3RD ST G3 & G4	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.07243	-118.35963	TI TO RETAIL SPACE WITH JUICE BAR. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33761	13041-20000-22849	21011 S LA SALLE AVE	90501	15	051B193   106	7349003021	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	33.83873	-118.30535	pv1 single family dwelling. total system size 3.6 kw using 16 modules. transformerless inverter. pc required. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33762	19041-10000-09017	18025 W VENTURA BLVD	91316	5	171B125   350	2162005131	(Q)C2-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.16497	-118.52509	NEW FIRE ALARM SYSTEM IN A NEW STARBUCKS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33763	12041-20000-10007	10969 W WILSHIRE BLVD #1700	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	PIN	34.05780553	-118.4459426	Alteration to lighting in various rooms of suite 1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33764	11041-20001-04685	18700 W VENTURA BLVD #170	91356	3	174B121   811	2161026002	C2-1VL	South Valley	Encino - Tarzana	Tarzana	YES	1394.01	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.17045	-118.54081	Changes from previously approved plans.  Changes include relocate electrical equipment inside the electrical room.  Plan check for power and energy.  Note: Permit issued under 11041-20000-04685*****PLAN CHECK POWER AND ENERGY FIRST TIME TENANT TO SHELL BUILDING T.J. MAXX RETAIL*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33765	19041-30000-09833	2029 S CENTURY PARK EAST 26th-27th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site are parts of the 26th and 27th floors. Project scope is a tenant improvement. Total lighting area = 1,260 sq. ft.Note: Building permit has been issued under 19016-10000-04862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33766	19041-10000-20489	3475 E WHITTIER BLVD	90023	14	121-5A227 158	5188004036	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.02687	-118.19853	T-24 plan check for a TI to Bank of America outdoor lighting. Total affected area is 40,764 sq.ft. The scope of work is conversions Electrical and other work as required to bring Branch Lighting into compliance with Bank Standards for Illumination around Financial Centers. Adding 1 new fixtures, add 3 new poles and its fixtures, add 1 new fixture- MATCH EXISTING CANOPY, remove and patch 2 fixtures, and replace 5 fixtures.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33767	15041-20000-27331	14318 W VENTURA BLVD	91423	4	165B153   374	2266002054	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.15013	-118.44497	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,326 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33768	14041-20000-31377	22832 W STRATHERN ST	91304	12	189B097   441	2014011005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.21533	-118.62476	Roof mounted PV system with Enphase model M215-60-2LL-S22.  Total system size 4.6 KW.Note: the solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33769	09041-10002-18410	410 N HAWAIIAN AVE	90744		027B201    26	7417010900			HARBOR CITY	WILMINGTON			Electrical	Electrical	Apartment			03/31/2011 12:00:00 AM			PC Approved	05/02/2011 12:00:00 AM	ADDRESS	33.7736	-118.27616	DELTA 3 CHANGES TO THE APPROVED PLANS.  (Using Aluminum Feeders) <<<<<<<New 100 unit three story apt bldg. new service, panels. Two typical units. Fire alarm submital with variance. Indoor and out door title 24.  The apartment building is in a Methane Zone.>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33770	14041-10001-14924	4534 N VAN NOORD AVE	91604	2	168B161  1071	2362006005	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/31/2014 12:00:00 AM	ADDRESS	34.15323	-118.41483	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.335 ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFPORMERLESS INVERTER. WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33771	16041-10000-00616	4839 N LOWELL AVE	91214	7	201B205   435	2571003025	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Expired	02/06/2018 12:00:00 AM	ADDRESS	34.24719	-118.26621	PV1, rooftop solar installation, 4.2 kW AC(20) KU2656ZPA(1) PVI-4.2-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33772	18041-20001-34197	21000 W PLUMMER ST BLDGS-A&B	91311	12	198B109    41	2746008014	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM			PC Approved	09/16/2019 12:00:00 AM	ADDRESS	34.24253	-118.59179	9/16/19CHANGES TO APPROVED SET DELTA 1 CHANGES TO WIRING IN FLOOR PLAN.<<<ti to existing sleeping quarters in a commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy indoor only>>>.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33773	14041-20001-00980	16738 W SUNBURST ST	91343	12	195B137    70	2688024045	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.23467	-118.49765	pv1 single family dwelling. total system size 6kw ac using 4 strings transformerless inverter using 20 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33774	14041-20000-28142	10100 W SANTA MONICA BLVD #1070	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI to (E) commercial office space on 10th floor of commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33775	12041-10000-18043	682 W HARRY BRIDGES BLVD	90744	15	027B201   336	7440015***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.77	-118.26886	NEW 1-STORY YARD OPERATIONS BUILDING FOR THE PORT OF LA. EPC IS FOR POWER & ENERGY. (PART OF TRAPAC TERMINAL PROJECT).  Fire alarm is on the supplemental permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33776	11041-10000-03252	21200 W OXNARD ST	91367	3	177B105    75	2149002008	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02, 1371.02	Electrical	Electrical	Commercial			02/18/2011 12:00:00 AM	02/18/2011 12:00:00 AM		Permit Finaled	03/25/2011 12:00:00 AM	ADDRESS	34.17905	-118.59389	addition 6 devices and a panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33777	15041-10001-15988	5513 W RIDGE OAK DR	90068	4	153B193   144	5580027020	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.11482	-118.31	EXPEDITED RSES PLAN CHECKPER APPLICANT REQUEST.<<PV1, INSTALL 7.19 KW DC ROOF-MOUNTED SOLAR ARRAY ON A RESIDENTIAL HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: SUNPOWER SPR 327ne-wht-d(1) INVERTER: ABB PVI-6000-OUTD-US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33778	18041-10000-15333	355 S GRAND AVE 21ST FLR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR TITLE 24 ONLY . CORRIDORS AND ELEVATORS LOBBY - TOTAL AFFECTED AREA = 735 SQ. FT.   building permit # 17016-10000-35284	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33779	17041-10000-21488	6801 W HOLLYWOOD BLVD D4-413	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM			PC Info Complete	10/02/2017 12:00:00 AM	ADDRESS	34.10229	-118.33907	TI TO EXISTING RESTAURANT. WORKD DONE IN ASSEMBLY OCCUPANCY > 100. PC FOR POWER AND ENERGY. EXISTING EQUIPEMNT WITH NEW CIRCUITRY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33780	18041-10001-04670	10250 W SANTA MONICA BLVD #1250	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Delta 3 revisions to lighting and power plans. Relocate restroom; new enclosed office; uses OCP panel with track lighting system.(((((Plan check for T24 only, TI for an (E) retail space in Westfield Century City.  New lightings and power using an Existing 100A tenant's panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33781	14041-20000-11452	9322 1/2 N BURNET AVE	91343	7	198B145   168	2656021***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Expired	05/24/2016 12:00:00 AM	ADDRESS	34.23965	-118.46304	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. 2 STRINGS COMBINE, 3RD STRING SINGLE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33782	17041-20000-37249	10303 N NORRIS AVE	91331	7	204B165   123	2537005014	M1-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.25696	-118.40297	new fire pump to an existing storage building.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33783	18041-10001-07526	10144 N FARRALONE AVE	91311	12	204B101   370	2745002006	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.25484	-118.61027	PC FOR ROOF MOUNTED PV PER INSPECTION. THIS IS PLAN CHECK ONLY, PERMIT FEES PAID UNDER MASTER APPLICATION. Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33784	15041-10000-16359	19843 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.23209	-118.56583	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 8156 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33785	16041-10000-33174	855 W 125TH ST	90044	15	081B197   178	6117016026	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	33.91869	-118.291	Install PV1 rooftop solar on (E) SFD. (1) SE3800A-US,  (14) CS6X-320P,  power optimizer is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33786	15041-10000-28783	514 W 62ND ST	90044	9	105B201   904	6004022004	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	33.98317	-118.28322	PV1, ROOF MOUNTED SYSTEM, (15) MODULES AND (1)  INVERTER. (15) KYOCERA #KU2656ZPA(1) PVI-3.3-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33787	13041-20000-34242	3811 N ROYAL MEADOW ROAD	91403	5	162B141   283	2280011028	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.13927	-118.47699	PV1 TRANFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.8KWAC. 28 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33788	15041-10004-27170	426 E 58TH ST	90011	9	108B205  1058	5101006006	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	33.98972	-118.26645	CHANGES TO APPROVED SET OF PLANS. RECONNECTING 2 EXISTING PANELS TO NEW DISTRIBUTION SYSTEM. CHANGES NOTED DELTA 7 ON PLANS. permit issued for the reconnections	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33789	17041-20000-03799	19210 W CALAHAN ST	91324	12	198B121   728	2762017015	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.23636	-118.55078	"""0$ permit fees due to senate bill 1222""PV1.  Install 17.955 kW roof mounted grid tied PV system.  (57) modules with (2) 7.6 kW rated central inverters."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33790	19041-10000-10260	13100 N TELFAIR AVE	91342	7	222B141    52	2604002048	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.30763	-118.47752	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33791	12041-10000-03428	5005-5025 S MAIN ST	90037	9	111A203   297	5110024005	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Apartment			02/14/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	33.99714	-118.27431	New 89-unit 5 story apartment building with one level of underground parking.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33792	15041-20000-21851	20001 W GRESHAM ST	91324	12	195B113   195	2782033007	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	PIN	34.23104994	-118.56914872	PV1 SFD. TOTAL SYSTEM SIZE 7.5KW AC USING SINGLE INVERTER. 3 STRINGS. 21 MODULES TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33793	19041-20000-52806	4820 N GENTRY AVE	91607	2	168B165   448	2355012022	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Issued	12/20/2019 12:00:00 AM	ADDRESS	34.15827	-118.39302	PV1.  Install 7.56 kW roof mounted PV system with 27 kWh energy storage system.  (24) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33794	14041-20000-27051	865 S FIGUEROA ST Suite 3150	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.04653	-118.26275	PC FOR ENERGY. TI. SUITE 3150. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33795	17041-10000-18262	12408 W VAN NUYS BLVD	91331	7	213B165   699	2532010104	A2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.27905	-118.40401	PC FOR FA.  CHANGE OUT OF FACP PANEL WITH ONE NEW SMOKE DEDTCTOR. TOTAL DEVICE COUNT IS 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33796	18041-10000-11941	11680 W BURBANK BLVD	91601	2	174B169   887	2350001017	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.17198	-118.38715	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33797	15041-20000-27468	1027 S WESTWOOD BLVD	90024	5	132B149    25	4363018028	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Issued	08/21/2015 12:00:00 AM	ADDRESS	34.06201	-118.44565	Plan check Title 24 only for existing space T.I. Total indoor area: 1,210 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33798	11041-10000-25510	14309 W BURBANK BLVD	91401	2	174B153   754	2245010051	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Apartment			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.1723	-118.44467	New fire alarm system for apartment bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33799	14041-10000-30663	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	33.79072	-118.29449	Energy plan for a medical administrative office ( not a  patient care area) T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33800	15041-20000-19304	15140 W WYANDOTTE ST	91405	6	186B145   798	2221019035	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Expired	07/18/2017 12:00:00 AM	ADDRESS	34.2029	-118.46315	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 7.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33801	12041-10000-01282	400 W WORLD WAY Term. 4-Spc#4C	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. to an existing retail space at LAX, terminal 4, space 4C.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33802	14041-20000-08365	685 S NEW HAMPSHIRE AVE	90005	10	132B197   143	5094008004	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM			Reviewed by Supervisor	04/07/2014 12:00:00 AM	ADDRESS	34.06041	-118.29315	800A temporary power for construction and related distribution equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33803	14041-20000-35000	2607 W SUNSET BLVD	90026	13	141A205   215	5402015023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1956.00	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM			PC Info Complete	01/22/2015 12:00:00 AM	ADDRESS	34.08024	-118.26981	ADDITION OF ELECTRIC ROOM. RELOATE ELECTRICAL SERVICE EQUIPMENT TO OTHER SIDE OF BUILDING. 800A 240V 3PHASE 4W. RECONNECT EXISTING LOADS AND COUPLE NEW PANELS. NEW FEEDERS CHARGED AS PANEL BOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33804	12041-10000-14322	14353 W FOX ST	91340	7	210B149   770	2613025900	(T)(Q)C2-1VL	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.27179	-118.44627	PLAN CHECK POWER AND ENERGY FOR NEW PUBLIC PARK. NEW 100A SERVICE, PANEL, AND CKTS.  NO METHANE MITIGATION REQUIRED FOR INSTALLATION ABOVE 5 FEET DEPTH IN OUTDOOR METHANE BUFFER ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33805	15041-10002-30970	11455 W BURBANK BLVD BLDG C	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	CHANGES TO APPROVED SET OF PLAN. CHANGES UNDER DELTA 11 AND 12. CHANGES  INCLUDE:  T24 FLOOR PLANS /CALCULATIONS,  LIGHT CONTROLS AND LIGHT FIXTURES, ADDITION OF 600A PULL SECTION AND CHANGE OF FAULT CURRENT AND AIC RATINGS, AND ADDITION OF FIRE SMOKE DAMPERS . CHANGES TO REFLECT ON THE FIELD.THE DRAWING  PLAN INCLUDES ALL BUILDING A, B AND C IN ONE SET.<<<<<TI to an exisiting religious assembly site (2-story building), Church of Scientology-Area C. New 600 Amp service, all equipment is new. Full Plan Check. Total Sq ft = 29,141.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33806	19041-10000-45167	445 S FIGUEROA ST 13TH FL	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	T-24 ENERGY PLAN CHECK. SCOPE INCLUDES INSTALLATION OF NEW LUMAINAIRES AND RECEPTACLES. AFFECTED AREA OF WORK 360sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33807	18041-20000-45776	15833 W VOSE ST pv1	91406	6	183B141   284	2224005004	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.19855	-118.47829	pv1install roof mounted pv system sized 3KW AC interconnected with msp.  this is an addition to an existing pv system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33808	19041-10000-45811	13884 N GRABER AVE	91342	7	228B161    85	2582026009	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.32423	-118.40912	PV1. LADWP Community Solar Program: 5.00KWdc / 4.76KWac - 17 solar modules and 17 enphase IQ7-60-2-US micro-inverters. PV system interconnected to a service via a meter adapter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33809	15041-10000-38826	3701 W WILSHIRE BLVD 9TH FL	90010	10	132B193    27	5503029024	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.06188	-118.30708	11-17-2015Changes to an approved set of plans, note changes on delta 2. scope of work includes new fixture type, new panels and new controlled receptacle system. Approved plans under application number: 15041-40000-11700. ((REMODELING OF OFFFICESPLAN CHK IS FOR TITLE 24permit number was generated under San Pedro office.  However, it was generated in Metro)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33810	17041-10000-40640	8500 W BEVERLY BLVD #117	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	Full plan check for a first time tenant T.I restaurant. Scope include new electrical equipment and lighting. Total area is 7,538 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33811	19041-20000-33327	1170 S LA BREA AVE	90019	10	132B181  1202	5084021015	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.0541	-118.34323	Plan check for fire alarm system 3 separate building has 1 fire alarm system. Total fire alarm device: 35 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33812	17041-20000-18309	515 S FIGUEROA ST #600	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for energy only. TI to office suite 600 in high rise office building. New lighting (incl. emergency) - 11,896sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33813	08041-10002-19402	639 N BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Apartment			08/06/2013 12:00:00 AM			PC Info Complete	08/19/2013 12:00:00 AM	PIN	34.05985996	-118.23998637	[[[[[[[SUPPLEMENTAL APP FOR 08041-10000-19402,07/25/13]]]]]]New Mixed-Use apartment retail complex.  Permit is for new service, new panels, new dist. boards, new ckts, new equipment, new lighting fixutres.  P/C is for Power and Energy.   A variance to separate the electrical and fire alarm plan check and permitting was submitted on November 25, 2008.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33814	19041-10000-27898	3330 W WILSHIRE BLVD	90010	10	132B197    59	5094007021	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.03	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	12/31/2020 12:00:00 AM	ADDRESS	34.06156	-118.29499	PLAN CHECK FOR TENANT IMPROVEMENT. NEW PANELS WITH LOADS AND NEW EQUIPMENTS. TOTAL NEW CONNECTED LOAD OF APPROX 400A TO EXISTING SERVICE. TOTAL AFFECTED AREA =10304SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33815	14041-20002-21491	18321 W VENTURA BLVD SUITE #100	91356	3	171B125    82	2160009005	C2-1L, PB-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	34.16715	-118.5315	Change from the previously approved plans for existing high rise building.  Replace emergency unit equipment with emergency generator connected fixtures.Note: Permit is under a separate application.*****Previous Description*****11/18/2014 - Modification to approved set. Plan check for changes - add photocells in daylit zones, update all controls to a Watt Stopper control system (including dimmers, occupancy sensors, and relays).[CHG OF USE TO BANK FROM OFFICE & TI. pc for t24 energy only. new lighting.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33816	18041-20001-19166	30 N LATIMER ROAD	90402	11	126B133     2	4409013013	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.04484	-118.51179	Expedite per applicant request PV1.  Install 21.6 kW DC roof mounted grid tied PV system.  (72) modules with (3) 7.7 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33817	19041-20001-32379	12236 W GORHAM AVE	90049	11	129B141   475	4264012007	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM			PC Approved	09/09/2019 12:00:00 AM	ADDRESS	34.04776	-118.47351	CHANGES TO APPROVED SET CHANGES INCLUDE CIRCUIT BREAKER SIZE TO 40 AMP.<<<PV1.  Install 8.68 kW roof mounted grid tied PV system.  (28) modules with 10 kW rated string inverter.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33818	18041-10000-42043	9711 N MASON AVE	91311	12	201B109   211	2748005031	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.24676	-118.57997	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33819	16041-10000-39954	700 W 7TH ST G80, G230,-G420, G630	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR TITLE-24. ENERGY ONLYSOCPE INCLUDES  4 TENENAT SPACESTOTAL AFFECTED AREA OF 6303 SQ.FT. BLDG APP# 16016-10000-26529Suites G80, G230, G420, & G630.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33820	15041-10003-37113	22635 W CANTARA ST	91304	12	189B097    79	2013006018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.21784	-118.62027	04/04/2016CHANGES TO AN APPROVED SET OF PLANS NOTE CHANGES ON THE CLOUDED AREA. CHANGES INCLUDE THE MODULE LAYOUT. (((Install a roof mounted solar array on a SFD. Interconnect with 200A MSP w/ a 175A main.System size: 10.2kW (6+4.2). Ungrounded system. (35) 327W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33821	15041-10000-04753	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.01925	-118.37654	INSTALLATION OF NEW 150KVA  UPS ,PDUS AND CIRCUITS, ATS, AND DISTRIBUTION BOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33822	17041-10002-42276	13448 W BEACH AVE	90292	11	108B149  1378	4230004022	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			03/01/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	01/13/2021 12:00:00 AM	ADDRESS	33.99058	-118.44547	Change to approved set by adding a fire pump and modify the feeder and fault current on single line diagram. All changes under delta-3 only.(((Plan check for power and energy 7-Story 228 Unit Mixed Use Apartment Building with 43 typical units. Total area: 161,386 sq ft. 4000A Service at 480VB#16041-10000-02510Fire alarm variance has NOT been File)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33823	19041-10000-03946	1375 E LAKE ST	90291	11	114B149   795	4244003034	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.0069	-118.45478	PLAN CHECK FOR A NEW ROOFTOP SOLAR SYSTEM  AND ENRGY STORAGE SYSTEM IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES 12 MODULES ( Q-PEAK 315W). ONE CENTRAL INVERTER (DELTA SOLIVIA 3.8) AND ONE 13.5KWH  BATTERY(TESLA POWERWALL). SYSTEM SIZE IS 3.8KWac AND 3.78KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33824	16041-30000-18514	17188 W SAN JOSE ST	91344	12	207B133   893	2695014020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.26107	-118.50851	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33825	10041-20001-02204	6314 W SANTA MONICA BLVD	90038	13	144B185   728	5533017003	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM			PC Approved	08/16/2010 12:00:00 AM	ADDRESS	34.09058	-118.32723	PLAN CHECK ONLY.  REVISION TO T-24 ENERGY CALCULATION AND LIGHTING PLAN FOR 2 STORY RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33826	16041-20000-29237	21030 W BLYTHE ST	91304	3	189B105   233	2109013005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.21507	-118.59186	Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (35) modules, (35) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33827	19041-10000-10254	13100 N TELFAIR AVE 1st floor	91342	7	222B141    52	2604002048	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.30763	-118.47752	REPLACE INDOOR FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITSLOCATION IN SHOW ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33828	18041-10000-45463	6100 N WOODLEY AVE	91436	6	177B141     3	2251002906	OS-1XL-RIO, [Q]PF-1XL-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	07/27/2023 12:00:00 AM		Issued	07/27/2023 12:00:00 AM	ADDRESS	34.18088	-118.48309	PC FOR POWER ONLY FOR TWO OPTIONAL STANDBY DIESEL GENERATORS IN A COMMERCIAL FACILITY (WASTEWATER FACILITY). SCOPE INCLUDES NEW MEDIUM VOLTAGE FEEDERS(4160V) FOR NEW GENERATOR. NOTE: ELECTRICAL EQUIPMENT INSIDE OR PART OF THE PREFRABRICATED OUTDOOR ENCLOSURE IS NOT PART SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33829	18041-20000-12135	743 S LUCERNE BLVD	90005	4	132B189    48	5090019001	CR(PKM)-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.06071	-118.32483	Plan check for power only. Project site is an existing commercial building. Project scope is the replace of HVAC equipment and new distribution boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33830	16041-30000-17313	4100 S WEST BLVD	90008	8	114B181   149	5031003001	[Q]RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01049	-118.34662	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33831	11041-20000-07886	127 S SAN VICENTE BLVD Bulletin-19	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM			PC Approved	04/20/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 19 plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33832	17041-20000-11981	4334 N COLBATH AVE	91423	4	165B153   389	2271015***	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.14985	-118.43644	new fire alarm panel reconnect existing 52 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33833	17041-10000-08453	1320 W 47TH ST	90037	9	111B197   574	5017004030	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.00052	-118.29889	Installation of a PV1 roof mounted soalr system. Central inverter 3.8 KW, 21 solar modules w/ optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33834	13041-20000-00937	1776 S GARTH AVE	90035	5	126B173    98	4303027021	R1-1	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.0452	-118.37778	New 3.185kw rooftop photovoltaic system with an Ungrounded Inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33835	18041-20000-09526	1026 W 34TH ST 120 - 122	90731	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.02414	-118.28985	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,902 sq. ft.Note: Building application has been generated under 17016-10000-37520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33836	15041-10000-31983	9245 N RESEDA BLVD	91324	12	198B125   219	2763009002	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM			PC Info Complete	09/28/2015 12:00:00 AM	ADDRESS	34.2385	-118.53628	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33837	15041-20000-35688	523 W 6TH ST 29TH FLR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM			PC Approved	10/26/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI;  NEW SUSPENDED CEILING AND LIGHTING AT 29th FLOOR CORRIDOR AND ELEVATOR LOBBY.  1983 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33838	15041-10001-12519	600 WORLD WAY TERM 6-T-649	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	(((6-18-2015: Changes made to approved set. Removed some lights and changed jbox to receptacle. Clouded changes only.)))PC FOR POWER AND ENERGY. TERMINAL 6 OF LAX. FIRST TIME TENANT . TOTAL  AREA  IS 610 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33839	15041-20000-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.25734	-118.50614	CHANGE OF USE TO MEDICAL OFFICES. FULL TI. PC FOR POWER AND ENERGY. PER BUILDING PERMIT, PC IN ACCORDANCE TO 2008 NEC AND ENERGY CODE STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33840	18041-20000-37380	7935 N ETHEL AVE	91605	2	189B161   475	2303026003	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.21511	-118.41639	PV1.  Install 4.06 kW roof mounted grid tied PV system.  (14) modules with 3.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33841	12041-10000-00179	3601 S TROUSDALE PKWY B7	90089	9	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	34.02017	-118.28558	T.I. to the basement of the USC Student Union.  Addition of walls and relocation of lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33842	14041-20000-16264	21600 W OXNARD ST 18th flr	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Expired	07/28/2016 12:00:00 AM	ADDRESS	34.179	-118.6002	Tittle 24 plan check only on remodel 2 private offices on 18th flr existing lights and circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33843	18041-10000-25290	300 S GRAND AVE	90071	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	02/26/2021 12:00:00 AM	ADDRESS	34.05283	-118.25116	PC FOR INSTALLATION OF NEW OUTDOOR RATED GENERATOR WITH FUEL TANK,  FOR EXISTING LOADS. TOTAL 200 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33844	17041-20001-02958	11900 N EL ORO WAY	91344	12	216B133   407	2606024006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.28762	-118.50311	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 150A. 12kW ungrounded system (6kW*2). (44) 327W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33845	19041-10000-53288	15640 W ROSCOE BLVD	91406	6	192B141   489	2673022036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/20/2021 12:00:00 AM		Permit Finaled	07/26/2022 12:00:00 AM	ADDRESS	34.2211	-118.47407	FULL POWER PLAN CHECK FOR A 600 AMP, 480/277V, 3-PHASE 4-WIRE SYSTEM. SCOPE OF WORK INCLUDES PANELS, TRANSFORMERS, MOTORS, GENERATOR, CIRXUITS, AND LIGHTING. TOTAL AFFECTED AREA: 150,361 SQ FT****NOTE: GENERATOR HAS BEEN APPROVED BY THE FIRE DEPARTMENT WITH A FIRE APPROVAL STAMP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33846	12041-10000-01904	500 W WORLD WAY 5K	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Approved	03/28/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. to an existing retail space.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33847	18041-20001-09402	14612 W CALVERT ST	91411	6	177A151    14	2241022004	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.18153	-118.45136	Revisions to approved plans to address mechanical revisions.  Mechanical room conditioning and ventilation equipment, and addition of smoke guards/smoke fire dampers.(((Plan check for power and energy. Project site is a new 4-story, 19-unit apartment building. Work includes an 800-amp service and a total lighting area of 14,411 sq. ft.Note: Building permit has been issued under 17010-20000-02238)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33848	19041-20000-23195	11019 N CANBY AVE	91326	12	210B125   537	2715002046	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.27027	-118.53504	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 17.16KW DC/14.586 KW AC CEC/16.38 KW AC. SCOPE OF WORK INCLUDES (52) PANASONIC PV MODULES WITH IQ7X MICROINVERTERS, AND A NEW 125A DISTRIBUTION PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33849	16041-10000-27795	6901 N LENNOX AVE	91405	6	183B149   473	2217010045	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.19586	-118.44562	Plan check for T-24 only. Remove outdoor HID fixtures and replace with new LED fixtures. Total affected area: 55438 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33850	17041-10000-38723	6775 W SELMA AVE A1	90028	13	148-5A185 276	5547013017	C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.0998	-118.33817	PC FOR A NEW FIRE ALARM SYSTEM FOR BUILDING A1(BLDG 2 OF 2). NOTE: TWO FIRE ALARM SYSTEMS ARE UNDER ONE SET OF PLANS, ONE FIRE ALARM FOR EACH BUILDING. SCOPE INCLUDES 391 FA DEVICES, AND 5 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33851	13041-10000-29814	11233 N SAN FERNANDO ROAD	91331	7	210B157   166	2616030063	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.2739	-118.43067	proposing to install (2) new 1999 GAL PROPANE TANK above ground in LAUSD bus parking lot. located in methane zone. area is class I div I classification for entire space within dispenser enclosure. (2) 50A-3Pole  16599 KW fuel pumps on existing 200A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33852	11041-10000-21039	366 W 8TH ST	90731	15	015B201   249	7455011023	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Apartment			10/03/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	33.73704	-118.28519	Fire alarm system for 5 story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33853	17041-10000-44895	360 E 2ND ST GND FL	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	NEW LED DOWN LIGHT LUMINAIRES IN CORRODOR/STORAGR/RESTROOM IN AN OFFICEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33854	17041-10000-41093	223 N CHEESBROUGH'S LANE	90063	14	126A229   109	5179020015	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.0382	-118.19286	REPLACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33855	17041-20000-21779	6420 W WILSHIRE BLVD Suite 1900	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for energy only. TI to existing office suite 1900 in high rise building. New lighting (incl. emergency) - 2,728sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33856	15041-10000-34208	200 WORLD WAY TERM 2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	TEMPORARARY POWER TO KEEP  LAX TERM 2 OPERATING; AN 800A SECTION FROM A EXISTING 3000A SWBD SUPPLIES POWER TO LISTED POWER SKIDS WHICH IN TURN SUPPLIES PANELBOARDS;	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33857	18041-10000-25567	7900 N SAN FERNANDO ROAD	91352	2	189B177   281	2407013020	MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Issued	07/10/2018 12:00:00 AM	ADDRESS	34.21523	-118.36234	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33858	17041-10000-39764	801 S FIGUEROA ST 10TH FL	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	ALTERATIONS IN CONFERENCE ROOM AND RECEPTION AREA AND PANTRY OF OFFICE AREASPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33859	14041-20000-34607	328 E 12TH ST	90015	14	124-5A209 134	5145027033	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.03563	-118.25679	PC FOR T24 ENERGY ONLY. FIRE DAMAGE. NEW LIGHITNG AND RESTORATION OF SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33860	12041-20000-10911	4940 N PASO ROBLES AVE	91316	5	168B133    24	2258019001	(T)(Q)R3-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Apartment			05/11/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.16074	-118.50202	New 52 unit apartment. HIgh-rise residential building. Plan check for power and energy. 68835 conditioned sqft. Fire alarm variance on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33861	12041-10000-04116	700 W WORLD WAY TERMINAL 7-SPACE  7F	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	INTERIOR BUILD-OUT (640 SQ) FOR HUGO BOSS SPACE 7F, TERMINAL 7. EPC IS FOR ENERGY & EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33862	18041-20000-45403	12380 N LONGACRE AVE	91344	12	219B125   130	2601075082	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.29477	-118.53441	installation of (2) tesla powerwalls to an existing pv sysem.  plan check for power only.(2) 200 amp subpanels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33863	16041-10000-00243	12027 W VOSE ST #10	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.39523	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33864	14041-20000-27126	4413 N PETIT AVE	91436	5	165B137    98	2289028014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Expired	11/01/2016 12:00:00 AM	ADDRESS	34.15145	-118.4965	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222install roof mounted pv system sized 13.6kw interconnected with msp.(62) kyocera kd255 modules(62) power optimizers p300(3) solar edge inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33865	16041-10001-11362	12751 W MILLENNIUM #130	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	CHANGE TO APPROVED SET OF PLANS. ADDITION OF 2 PANELS FOR RELOCATION OF CIRCUITS TO COMPLY WITH DISSAGGREGATION REQUIREMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33866	16041-10000-43681	1626 S LONG BEACH AVE	90021	14	120A213   271	5167002038	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			Reviewed by Supervisor	12/20/2016 12:00:00 AM	ADDRESS	34.02242	-118.24254	PV2 roof mounted solar system on commercial site. Installing a central inverter rated at 14.4 KW being fed by 68 solar modules and optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33867	19041-20000-02317	24230 W STONE BEND LANE	91304	12	192B089   224	2017038025	RE9-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.21967	-118.6556	PV1.  Install 5.04 kW roof mounted grid tied PV system.  (16) modules with 5.2 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33868	15041-10000-24845	2407-2419 E 1ST ST	90033	14	127-5A223 164	5180002016	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.04369	-118.20936	NEW 5 STORY MIX USED MULTI  FAMILY BLDG WITH 50 APARTMENTS UNITS AND BASEMENT PARKING. 30 TYPICAL-1 BEDROOM UNITS, 2 BEDROOMS - 4 TYPICAL , 16 TYPICAL- 3BEDROOMS APARTMENT UNITS. 2 COMMERCIAL UNITS IN THE FIRST FLOOR. FEES PER APPLICANT. METHANE ZONE AREA *** VARIANCE FOR FIRE ALARM ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33869	10041-10002-05901	8100 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2766.02, 2780.00	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	33.95164	-118.43579	Install 20 new construction trailers in LAWA-LAX (Phase 2 & 3). Each trailer has 1 panel, 6 circuits & 1 AC unit.  The trailers are prefabricated and are approved by the state. (((((((((Phase 1 for 8 Trailers was approved under 10041-10000-05901))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33870	15041-20001-10039	12465 W OSPREY LANE Unit 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	33.97923	-118.41018	Expedite per applicant request(((((Plan check for PV roof mounted system for tri-plex unit #3 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10020))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33871	15041-20000-05256	12174 N WOODLEY AVE	91344	12	216B137    70	2605007043	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2015 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.29115	-118.48887	PV1. Install roof mounted PV system sized 7.0 kW. Interconnected with main service panel. (28) Sunmodule SW285 Modules(28) Enphase M250 Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33872	13041-20000-16393	333 S GRAND AVE 46th Floor	90071	15	018B197  1671	7451019029	C2-4D, R2-1XL	Harbor	Central City, San Pedro	Central San Pedro, Downtown Los Angeles	YES	2966.00	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	Change to lighting/receptacles in an existing high rise building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33873	10041-10001-08861	121 N LA CIENEGA BLVD #835	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM			PC Approved	12/20/2010 12:00:00 AM	ADDRESS	34.07484	-118.37674	ON THE 8TH FL, CHANGES TO THE FLOOR LAYOUT AND LIGHTING SYSTEM; SAME ON THE 9TH FLT.I. to existing high rise building in 8th floor (EAST and WEST) and in 9th floor.  Install new panels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33874	12041-10000-23563	649 S ANDERSON ST	90023	14	124-5A219  35	5171017002	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.03708	-118.22337	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR EXISTING 1 STORY WAREHOUSE. PERMIT FOR NEW SERVICE, SERVICE PANEL,  AND BRANCH CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33875	18041-20000-47967	16556 W BIRCHER ST	91344	12	213B137   401	2610027031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.2811	-118.49302	PV1.  Install 10.5 kW DC roof mounted grid tied PV system.  (30) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33876	19041-20000-11515	22440 W CALIFA ST	91367	3	174B101    45	2040040008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.17673	-118.61629	INSTALLATION OF NEW ROOFTOP PV SYSTEM FOR A EXISTING SFD. SYSTEM SIZE IS 12.0KW DC/11.4KW AC/11KW AC CEC. SCOPE OF WORK INCLUDES (37) HANWHA Q CELL PV MODULES WITH P370 OPTIMIZERS, AND A SE11400H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33877	18041-20000-43411	4625 N SANTA LUCIA DR	91364	3	166-5A105  67	2171009065	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.1517	-118.60416	PV1.  Install 15.84 kW roof mounted grid tied PV system.  (44) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33878	16041-30000-18617	12132 W HART ST	91605	2	183B165   276	2321009039	R3-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.19732	-118.39782	Plan check for a fire alarm system in an existing apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (9) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33879	12041-20000-03666	127 S SAN VICENTE BLVD Bulletin-124 CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM			PC Approved	02/17/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin-124 CS REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33880	10041-20000-08799	1801 S AVENUE OF THE STARS #1248	90067	5	132B161    24	4319003061	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	07/13/2010 12:00:00 AM	ADDRESS	34.06072	-118.41826	energy plan check # 1248	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33881	16041-10000-27930	2423 E MALABAR ST	90033	14	130-5A225 327	5177021019	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Issued	08/15/2016 12:00:00 AM	ADDRESS	34.0501	-118.20475	PV, INSTALL 2.6 KW DC ROOF-MOUNTED SOLAR ARRAY on a single family house.(10) modules: canadian solar csp6p-260(1) inverter: solaredge SE3000A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33882	13041-10000-16816	5300 N SEPULVEDA BLVD 1-36	91411	4	172-5A145  61	2250003023	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			06/25/2013 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.16677	-118.46575	New 36-unit apartment building.  3 stories with grade-level parking.  Plan check for power and energy required.  No Title 24 forms included at time of submission.  Branch circuit counts were adjusted to meet applicant's check amount.PERMIT SHALL GE ISSUED AT ADDRESS 5308 N SEPULVEDA BLVD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33883	15041-20001-21013	14717 W CHATSWORTH DR	91345	7	210B149   863	2615015018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.2707	-118.45334	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (41) micro-inverters, (41) modules, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33884	14041-20001-15815	9268 W ROBIN DR	90069	4	147B169   191	5561006015	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2017 12:00:00 AM			PC Approved	08/07/2017 12:00:00 AM	ADDRESS	34.10121	-118.39137	Revisions to approved plans.  Change of power and lighting floor plans due to architectural changes.  (((Plan check for power only. New 2-story 17,542 sqft SFD. this is plan check only. permit fees collected by building)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33885	16041-20000-03876	601 S FIGUEROA ST 42ND FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HIGH RISE OFFICE. 42ND FLOOR .6660 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33886	13041-10000-08667	120 S LOS ANGELES ST	90012	14	130-5A213  98	5161016027	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.05092	-118.24262	T24 FOR NON HIGH RISE HOTEL. REPLACING EXISTING LIGHTS USING EXISTING CIRCUITS. 1000 SQ. FT. ELECTRICAL PERMIT WILL BE PULLED AT ELECTRICAL COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33887	10041-10000-10155	2301 W BELLEVUE AVE 11th Floor	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM			PC Approved	05/28/2010 12:00:00 AM	ADDRESS	34.07417	-118.26931	First time tennant, Dream Center, on the 11th floor of an exsiting building.  Power and energy.  Existing permit.  No net increse in panel load.  T-24 plan checked based on the 2005 Standard per instruction from Behzad.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33888	19041-20000-47247	1857 S PREUSS ROAD	90035	10	126B169   136	4303006018	R1V2	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.04488	-118.3855	PV1. INSTALL 8.58 KW DC PV SYSTEM WITH (26) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33889	17041-20000-17299	9515 N ROSLYNDALE AVE	91331	6	198B153   146	2642012004	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.24247	-118.43702	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33890	12041-10000-22972	4700 S INGLEWOOD BLVD	90230	11	108B161   213	4218008012	(Q)C2-1, C2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	07/09/2013 12:00:00 AM		Issued	07/09/2013 12:00:00 AM	ADDRESS	33.99346	-118.41537	New 600 Amp service to replace with an existing one. New panel & circuits. EPC for power. (T24 was ckecked under separate app.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33891	15041-10000-26958	2049 S CENTURY PARK EAST 2ND FLR-UST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING AND CONTROLS TO EXISTING PANELS. PC FOR ENERGY AND EMERGENCY LIGHTING ONLY. SCOPE OF WORK TO BE PERFORMED ON SECOND FLOOR. TOTAL AREA = 2615 SQ. FT.B# 15016-10000-16320.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33892	17041-20000-10834	23349 1/2 W MULHOLLAND DR	91364	3	168B093   181	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.1577	-118.63419	Plan check for energy only. Change of use from beauty salon to small sit down restaurant. New lighting. 848sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33893	12041-20000-25607	1611 S ELECTRIC AVE	90291	11	108B145  1414	4241037016	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	33.99035	-118.4631	T-24 lighting plan check for remodeled 2 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33894	13041-10000-12956	550 S HILL ST	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.04753	-118.25268	PLAN CHECK FOR TITLE 24. TENANT IMPROVEMENT REMOVING AND REPLACING OVER 50% OF THE LIGHTS IN AN EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33895	14041-10000-25567	1055 W WILSHIRE BLVD Suite 1000	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.05232	-118.2629	Title 24 plan check. Office, no changes in occupancy. Newly connected load <400amps. 1000 sq ft, emergency lighting. Suite 1000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33896	17041-10001-40640	8500 W BEVERLY BLVD #117	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	Changes to an approved set of plans. All changes are clouded under delta 5, 7,  8,  & 9. Changes include revising lighting floor plans, revising single line diagram, and revising panel schedules, and load calculations. Adding one 30KVA transformer, two new panelboards, new circuits, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33897	19041-10000-18913	200 W MESNAGER ST	90012	1	136-5A217 144	5409003040	UV(CA)	Central	Central City North	Historic Cultural, Historic Cultural North		2060.10	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	09/08/2022 12:00:00 AM		Issued	09/08/2022 12:00:00 AM	ADDRESS	34.06793	-118.22864	plan check for Metigation system, system consists of 1 FACP and 26 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33898	14041-20003-16816	6600 N TOPANGA CANYON BLVD #98A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM			PC Approved	07/24/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	plan check for T24 energy only. permit already issued under original application. due to building submittal, plan check in accordance to 2008 energy efficiency standards. new lighting inside tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33899	13041-20000-10942	826 E 3RD ST	90013	14	129A215   305	5163015025	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM			PC Approved	04/29/2013 12:00:00 AM	ADDRESS	34.04573	-118.23532	RENOVATION OF SPACE FOR KITCHEN, FOOD PREP AND INDUSTRIAL WORK. TOTAL AREA 2717 PLUS OUTDOOR LIGHTING. PLAN CHECK FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33900	15041-10000-04969	941 E 2ND ST #104	90012	14	129A217   108	5163005001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	ADDRESS	34.04727	-118.23375	Plan check for Title 24 only. Project is TI to a restroom and a break room within a tenant space. Total lighting area = 152 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33901	17041-20000-32629	13018 W BURTON ST	91605	2	192B161   245	2304003018	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.22053	-118.41724	Plan check for solar pv system, roof-mounted on SFD. Interconnecting with a 400A MSP.10kW ungrounded system. (36) 330W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33902	17041-10000-20351	8248 N LANKERSHIM BLVD	91605	6	192B169   505	2311001013	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.22059	-118.38757	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33903	14041-10000-13538	12766 W SHERMAN WAY 4	91605	2	183B161    54	2324006062	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.20103	-118.41158	Lighting for 12766 W. Sherman Way Unit #4REMOVE HID LIGHT FIXTURE AND REPLACE WITH NEW FLOURESCENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33904	11041-20000-13079	14800 W VENTURA BLVD	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	34.15186	-118.45547	A T & T ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33905	19041-20000-17922	14352 W CALVERT ST	91401	6	177A151    36	2240009002	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	10/29/2020 12:00:00 AM	ADDRESS	34.18154	-118.44621	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 690 sq. ft.Note: Building permit has been issued under 19016-20000-08922	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33906	16041-10004-42999	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Info Complete	06/21/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	Changes to approved by set of plans. plancheck check only.  All changes are clouded under delta 3. Changes include adding a new 3000A 4.16KV Medium voltage switchgear, new 100A panelboard, new outdoor lights, and adding cam-locks. Revising lighting floor plans for outdoor lights.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33907	14041-10000-05311	1119 W PACIFIC COAST HWY	90744	15	036B201   750	7414024034	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	33.79059	-118.27706	TI, T-24 only in dollar three, added load is less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33908	14041-10000-10566	14329 W CALIFA ST	91401	4	177B153  1061	2245016018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.17767	-118.44539	PV , micro inverters 4 modules , one string. one story.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33909	14041-10000-33364	11099 S LA CIENEGA BLVD Suite 210	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM			PC Approved	12/02/2014 12:00:00 AM	ADDRESS	33.93534	-118.37106	TI to (E) 3,560 sq. ft. commercial office space in 2-story commercial building.  Plan check for energy.  Permit obtained under 14041-10000-25965.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33910	19041-20000-21176	12316 N FINCH ST	90039	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	PIN	34.3012906	-118.58563914	Plan check for PV roof mounted system, PV system size: 5.03KW with 15 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33911	14041-20004-00054	18725 W SHERMAN WAY	91335	3	183B121    99	2118026018	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.20128	-118.54148	Plan check for a lost set of plans.no permit issued under this application. plan check only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33912	15041-20000-10722	7927 N TALL PINE CT	91352	2	189B177   966	2409007033	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			Corrections Issued	04/10/2015 12:00:00 AM	ADDRESS	34.2145	-118.36549	Installation of new roof mounted solar PV array.  Total system size = 4.2 kWac.  Single inverter system with two strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33913	19041-20000-01299	8867 W ALCOTT ST	90035	5	132B169  1018	4305014014	R3-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Apartment			01/11/2019 12:00:00 AM	11/15/2023 12:00:00 AM		Issued	11/15/2023 12:00:00 AM	ADDRESS	34.05422	-118.38609	New 17 unit apartment building 1200 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33914	14041-20000-14573	8118 N JUMILLA AVE	91306	3	189B117   130	2106014018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.21736	-118.56324	((PV system redesign. total size 6kw ac using transformerless inverter. using power optimizers.  Original plan check application under 13041-10000-33150)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33915	19041-20000-44967	4640 W HOLLYWOOD BLVD	90027	13	147B197   457	5542014007	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	05/03/2021 12:00:00 AM		Issued	05/03/2021 12:00:00 AM	ADDRESS	34.10006	-118.29052	New 800A 240/120V 3ph-4w service, distribution, power, and lighting for (E) building.  * Associated building permit to be clarified - not clear from permit record.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33916	17041-10000-41130	5607 N FIGUEROA ST	90042	1	151-5A229 281	5468033017	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.10923	-118.19396	change of use from retail to bar/restaurantFULL PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33917	19041-10000-08669	1010 W 25TH ST	90007	1	123A201    44	5124009902	OS-1XL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.03259	-118.28301	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33918	14041-20002-10472	4507 N ATOLL AVE	91423	4	165B157    64	2360027021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.15241	-118.42053	Modifications to approved set.  Change of module layout on rooftop.  $0 submittal fee is due to Senate Bill SB-1222. (((pv1 single family dwelling. total system size 6.4kw ac using microinverter enphase m215. nonstandard plan.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33919	18041-10002-34502	10419 W DUNLEER DR	90064	5	123B161    22	4318021023	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Issued	10/23/2018 12:00:00 AM	ADDRESS	34.03702	-118.41235	Changes to an approved set of plans. All changes are clouded. Changes include replacing enphase combiner box with a 125A panelboard, and revising conductor sizes from panelboard to service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33920	19041-20000-42103	7301 N MEDICAL CENTER DR #300	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.20262	-118.62963	TENANT IMPROVEMENT PLAN CHECK FOR POWER AND ENERGY ADD NEW (5) BRANCH CIRCUITS TOTAL AFFECTED AREA 2,124 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33921	15041-10000-38870	515 S FLOWER ST # 2800	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	NEW LIGHITNG IN STORAGE CLOSET. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33922	11041-10000-20224	625 E ANAHEIM ST	90744	15	030B209     8	7423024016	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	33.78052	-118.25524	PREVIOUSLY APPROVED SET WAS PERMITTED AND EXPIRED.  RECHECK.   ATTACHED APPROVED PLAN FOR REFERENCE ONLY.  <<<<<Installing gas injection skid. Plan check is for power.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33923	13041-10002-16249	1352 S RIDGELEY DR PV1	90019	10	129B177   775	5085033011	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM			Verifications in Progress	08/23/2013 12:00:00 AM	ADDRESS	34.04955	-118.35525	PV1.  Original express permit for 13041-10000-16249 for a roof-mounted system with transformered inverter modified to transformerless inverter.  Plan check only.  (((INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 1.47KW Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33924	15041-20001-28308	2422 W AVENUE 32	90065	1	150B213   381	5456009008	R2-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.04	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	34.10877	-118.23468	Change to approved set of plan. Changes include down size main breaker(Center feed) from 200A to 150A breaker. {{{{{{{Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33925	18041-20000-47386	823 W 132ND ST pv1	90247	15	078B197    80	6117027021	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	33.91241	-118.29024	pv1install roof mounted pv system sized 6.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33926	12041-10000-14499	2407 N LYRIC AVE	90027	4	150B201  1223	5433009001	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.10459	-118.27578	Plan check for PV system. 2.45kW DC for sfr, using transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33927	19041-10000-03875	817 N YALE ST	90012	1	135A215   252	5407021902	OS-1XL	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.06375	-118.24074	NEW FIRE ALARM SYSTEM WITH 70 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33928	16041-10001-20627	4929 N VAN NUYS BLVD	91403	4	169-5A151  49	2263026034	C1.5-1VL-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.16026	-118.4489	REVISED PLANS SHOWS THAT ONLY THE 250KVA FUEL CELL IS TO BE INSTALLED; PERMIT WAS OBTAINED BUT INSPECTION HAS NOT BEGAN AS OF TODAYTHIS IS PLAN CHECK ONLY!NO NEW PEMITTED ELEMENTS ON THIS SET. ALL PERMIT FEES PAID UNDER MASTER PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33929	16041-10000-33532	15400 W SHERMAN WAY SUITE 170	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.20099	-118.46839	Plan check for T-24 only. Interior TI on (E) office space. New 100A panel, install new lights and receptacles. (B# 16016-10000-15662)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33930	15041-20003-26370	1550 N GOWER ST	90028	13	147A189    19	5545008020	C4-1	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.09906	-118.32216	05/11/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to reflect field installation, changes have been made to the installed fixtures and the fixture schedule, and to address corrections made by inspection. All changes have been reflected onto the Title 24 Compliance Forms.04/28/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to reflect field installation and to address corrections made by inspection.*****Previous Work Description*****P.C for T-24 Energy only. Total area: 4364 sq.ft. TI to a studio on a low rise bld.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33931	15041-20000-23656	10539 N DE SOTO AVE	91311	12	207B109   538	2706017012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.26207	-118.5889	PV1. Install roof mounted PV system sized 6 kW. Interconneted with main service panel.(28) Kyocera KU2656(1) Fronius PVI 6.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33932	17041-20000-40438	4116 N ALONZO AVE	91316	5	165B129   301	2184039001	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM			Reviewed by Supervisor	11/14/2017 12:00:00 AM	ADDRESS	34.14533	-118.52439	addition of (1) tesla power wall to an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33933	10041-10000-15694	1817 S PROSSER AVE	90025	5	129B157   161	4321003133	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Public Safety Only			08/11/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	08/19/2011 12:00:00 AM	ADDRESS	34.05298	-118.4291	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33934	19041-10000-44047	24321 W WELBY WAY	91307	12	183B089   712	2034004011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.19394	-118.65452	PLAN CHECK FOR A PV1 SOLAR SYSTEM. SYSTEM SIZE 9.12KWdc(6000Wac) using 32 Q.ANTUM  BFR-G4.1 285 MODULEWS, 32 SOLAREDGE P320 POWER OPTIMIZERS, AND 1 SOLAR EDGE SE6000H-US INVERTER. CONNECTED TO AN EXISTING 125AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33935	12041-10000-06599	10250 W SANTA MONICA BLVD # 137	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	alterations in existing retail stor-new lighting and circuitsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33936	15041-10000-04618	8431 N TELFAIR AVE	91352	6	192B169   407	2632023038	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.22319	-118.38308	Energy plan check for replacing exising units to LED retrofit kits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33937	13041-10000-15843	13801 N BRADLEY AVE	91342	7	225B141    41	2603015033	RE11-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Expired	07/24/2015 12:00:00 AM	ADDRESS	34.31726	-118.479	PV1 6.125KW XFRMLESS. 2STORY. NONSTD. ROOFMOUNT. (1) powerone PVI-4.2-OUT-S-US-Z(25)TRINA TSM-245PC05.18}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33938	12041-10000-26070	5826 W OLYMPIC BLVD	90019	4	132B177   757	5085003031	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			10/30/2012 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.05724	-118.35691	Full plan check for new apartment building, four story, 12 unit. Project is located in Methane Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33939	16041-10003-15547	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	01/09/2017 Changes to an approved set of plans(331 pages of changes Century City Mall Package #5). Changes include , recircuiting distributive dimmer control panel on floor plan, changes lighing fixture types on lighing fixture schedule and floor plan exterior and interior, remove some lighting scope of work on floor plan. Changes has been clouded as delta 8. No new circuits or panels added.  {{{{{{{{{{{Supplemental to application nos. 13016-10000-16108 and 13010-1000002346 to incorporate all exterior facade, cladding and envelope systmes, exterior finish systems and common area interior finish systems (Package #5).}}}}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33940	16041-10000-11296	13025 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.18799	-118.41664	PC FOR POWER ONLY. SCOPE INCLUDES ONE NEW MAIN 1200A 120/208V 3 PHASE 4 WIRE MAIN DISTRIBUTION BOARD FOR A NEW 1-STORY SHELL AND CORE RETAIL BUILDING. ALSO ADDING TWO NEW SUBPANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33941	12041-10000-14509	1429 N GOWER ST	90028	13	147A189    94	5546024804	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.09699	-118.32249	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT ON THE THIRD FLOOR TELE EQUIPMENT ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33942	18041-20000-08084	22349 W ALGUNAS ROAD	91364	3	168B101  1032	2076018020	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.15257	-118.61527	INSTALLATION OF ENERGY STORAGE SYSTEM TO EXISTING PV SYSTEM. SYSTEM SIZE: 27KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33943	17041-20000-37846	21650 W OXNARD ST ste 700	91367	3	177B105    83	2146006042	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Closed	05/29/2024 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33944	18041-20000-00586	2044 S LINNINGTON AVE	90025	5	129B157   291	4317012048	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.05199	-118.42256	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.6 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33945	19041-10000-45866	12306 W VAN NUYS BLVD	91342	7	213B165   351	2531004004	[Q]MR1-1-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.05	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.28116	-118.4011	PC FOR ENERGY ONLY FOR OUTDOOR LIGHTING. TOTAL AFFECTED AREA IS 118250 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33946	18041-20000-31362	818 W 7TH ST #1200	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.04895	-118.25943	Tenant improvement of a suite on the 12th floor of an existing commercial highrise building. Note: Building application has been generated under 18016-10000-14036	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33947	12041-20000-19266	900 S FIGUEROA ST 4th Floor	90015	9	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			08/16/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.04604	-118.26272	Plan check for energy and emergency lighting. 1890 sqft. 4th floor fitness center. Outdoor lighitng was 200 sqft.  PERMIT FOR A NEW TRANSFORMER, PANEL, CIRCUITS & LOW VOLTAGE WIRING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33948	13041-20001-29243	21860 W BURBANK BLVD BLDG B	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.17198	-118.60379	Changes from previously approved plans.  Change include the use of let thru fuse to protect meter cabinet.  All changes indicate by DELTA-3.  Due to 2012 Senate Bill 1222, plan check is $0.00.Note: Permit is under the original application.****Previous Description:*****photo voltaic roof top for a 3 story bldg,768 modules, 3 combiner boxes, 2 inverters, Roof mounted , flat roof. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33949	16041-20000-04268	10635 N OAKDALE AVE	91311	12	207B113   116	2708020031	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	08/20/2016 12:00:00 AM	ADDRESS	34.26366	-118.5674	PV1.  Install ground-mounted 40 kW PV system.  (4) Frnonius Primo 10.0-1 inverters with (130) LG315N1C-G4 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33950	13041-10000-20661	12845 W SHERMAN WAY	91605	2	183B161     9	2324005033	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	34.20136	-118.41304	TITLE 24 PLAN CHECK ONLY. 1076 SQFT. EMERGENCY LIGHTING. RETAIL STORE. TMOBILE.  1 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33951	08041-10001-27421	3333 S MANNING AVE	90064	5	123B161   812	4316032011	R3-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.03112	-118.40638	Supplemental from previously approved plans.  Install outdoor lightings.  Plan check for energy only.  *****Plan check power/energy for remodel of existing units with new circuits (100 thru 109 and 200 thru 219) and addition of units in existing 2 story assisted living building.  New addition includes unit 110 thru 114 and units 220 thru 224.  New 1600A serivce, board, panels, and ckts.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33952	12041-20000-04602	1031 S HAYWORTH AVE	90035	5	132B177   724	5087025008	R2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2012 12:00:00 AM			PC Approved	03/07/2012 12:00:00 AM	ADDRESS	34.05738	-118.36546	Photovoltaic system on the roof of a single story single family dwelling. (EXPRESS PERMIT AND ZONING CLEARANCE WERE PREVIOUSLY ISSUED UNDER PCIS 11041-20000-25866)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33953	16041-20000-30908	1902 E MARENGO ST STE109-110	90033	14	132A223    33	5201016003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.05756	-118.21009	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY SUITE 109 AND 110.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33954	19041-10000-24239	776 S CERES AVE	90021	14	124-5A213 221	5146003037	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	08/12/2021 12:00:00 AM		Issued	08/12/2021 12:00:00 AM	ADDRESS	34.03609	-118.24478	POWER AND ENERGY PLAN CHECK FOR A NEW CONRETE BLOCK PARKING STRUCTURES. SCOPE INCLUDES NEW 800A SERVICE AND EQUIPMENT. TOTAL AFFECTED AREA IS 9221 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33955	19041-10000-19733	20360 W PLUMMER ST	91311	12	198B113    76	2748022077	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.24252	-118.57752	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33956	11041-10002-11314	1000 S HOPE ST C-2	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			No Progress	06/17/2011 12:00:00 AM	ADDRESS	34.04346	-118.2617	Electrical and energy for new medical office.  Existing permits 11041-10000-11314 and 11041-10001-11314.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33957	13041-10000-10577	19215 W VENTURA BLVD	91356	3	174B117   686	2163019013	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.17277	-118.55159	TI TO GOODWILL INDUSTRIES. EXISTING BLDG. <400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33958	15041-10001-01076	12518 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.97836	-118.41209	(3/3/2015) CHANGES TO AN APPROVED SET OF PLANS.  CHANGE FROM UNDERGROUND SERVICE TO OVERHEAD SERVICE. DELTA ONE REFLECT THE CHANGES DONE ON THE PLANS.Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33959	14041-20000-35464	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.21585	-118.47965	TI TO AN EXISTIING QUALITY COTROL TESTING CENTER (BAXTER).  ADDING NEW LIGHTING AND CONTROLS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1502.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33960	17041-10000-32514	345 N WESTMORELAND AVE 1-65	90004	13	138B197   140	5501002002	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Apartment			09/12/2017 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.07753	-118.28811	PC FOR FA IN 5 STORY APARTMENT BUILDING WITH UNDERGROUND GARAGE. TOTAL DEVICE COUNT 177 WITH 4 PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33961	12041-10000-01065	18607 W VENTURA BLVD #100	91356	3	174B121   559	2160006037	C2-1L, R3-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Approved	01/17/2012 12:00:00 AM	ADDRESS	34.17006	-118.53874	T.I. for an existing restaurant in suite #100.  New lighting and circuits.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33962	18041-20000-21524	7516 N MOORCROFT AVE	91303	3	186B101   326	2023017017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.207	-118.6111	PLAN CHECK FOR ROOF MOUNTED PV 6.0KVA SYSTEM CONSISTING OF CENTRAL INVERTER (SE6000H-US) WITH 17 MODULES AND POWER OPTIMIZERS (320)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33963	17041-10000-08999	901 S NORTON AVE	90019	4	132B189   970	5092004003	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.05541	-118.32008	Plan check for Title 24 only in existing space remove HID fixtures and replace with new LED fixture. Total area: 33400 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33964	11041-10000-10299	624 S GRAND AVE 1100	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	07/08/2011 12:00:00 AM	PIN	34.04778206	-118.25563275	DEMOLITION AND REPLACING 2 DC PLANTS.  NO NEW LOAD TO BE ADDED.  REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33965	11041-20000-18413	8212 N VAN NUYS BLVD	91402	6	192B149   510	2212004008	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills			1203.00	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.22017	-118.44858	Plan check power and energy first time tenant. New panel and ckts. Tenant power being supplied from service ( MSB2). Building electrical approved under #07041-20000-00851.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33966	17041-10000-22185	607 S PARK VIEW ST GROUND FL	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Issued	07/12/2017 12:00:00 AM	ADDRESS	34.06086	-118.27891	Title 24 plan check.  T.I. to women's and men's restrooms on ground floor.  Lighting area = 1,265 sq. ft.       Building permit #17016-10000-01006	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33967	10041-20000-00563	17380 W SUNSET BLVD	90272	11	126B117   650	4415019012	C2-1VL, C2-1XL, P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.01	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.03924	-118.55462	VONS MARKET REMODEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33968	14041-20000-03700	1021 N OXFORD AVE	90029	13	144B193   966	5536022006	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Expired	03/07/2016 12:00:00 AM	ADDRESS	34.08914	-118.30792	pv1 single fmaily dwelling. total system size 3 kw ac using transformerless inverter nonstandard plan. using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33969	17041-10000-38616	10250 W SANTA MONICA BLVD #2530	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space ""FINISH LINE""  suite 2530 in westfield Century City"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33970	19041-10000-47676	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	33.94248	-118.40461	ADDING NEW LIGHTING OUTDOOR FIXTURES ONTO A CANOPY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33971	13041-10001-18221	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			Reviewed by Supervisor	07/20/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	REVIEW OF PLANS IN WHICH REVISIONS TO PERMITTED SET OF PLANS ARE CLOUDE. NEW PLANS REPRESENT AS-BUILT SET ((((((((DISTRIBUTION BOARD REPLACEMENT ON 4TH FLOOR OF THE BEVERLY CENTER. One-for-one replacement of Distribution board associated with MSAA, MSBA, MSCA , MSDA, DSAA,  DSBA, DSBB, DSDB, EDUA, EDRB, EDRC, EDRD. See 13041-10000-27554 for Generator related issues.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33972	14041-20000-35472	6320 N CANOGA AVE 10TH FLOOR	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.18499	-118.59722	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES IN 10TH FLOOR. 1957 SQFT. EMERGENCY EXITING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33973	13041-10000-01395	1804 E 8TH ST	90021	14	123A215   132	5166027001	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.02989	-118.23863	TITLE 24 FOR COFFEE SHOP. RETAIL SPACE. TOTAL AREA OF 594 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33974	19041-10000-38999	3035 E ISABEL DR	90065	1	148-5A217  96	5455002025	R2-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.10258	-118.2336	$0 Fee Due to AB 1414. [EPLAN] PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES ARE CLOUDED UNDER DELTA A&B CHANGES INCLUDE ADDITION OF NEW METER/DISCONNECT AND RELOCATION OF MODULES Revision to 19041-10000-31137	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33975	17041-10001-20752	6036 W COMEY AVE	90034	10	123B173   457	5065012037	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2017 12:00:00 AM			PC Approved	07/13/2017 12:00:00 AM	ADDRESS	34.03441	-118.37569	Supplemental for expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33976	16041-10000-41622	707 W WILSHIRE BLVD #1500	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.04893	-118.2572	T-24, PC FOR ENERG ONLY. INTERIOR OFFICE TI FOR SUITE 1500. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL FFECTED AREA IS 7686 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33977	15041-10000-34595	10330 N SEPULVEDA BLVD	91345	7	204B145   217	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.25825	-118.46705	PC FOR ENERGY. RENOVATION OF EXISTING PARKING LOT.TOTAL AREA 267,464 SQ FT(OUTDOOR LIGHTING)B315026-10000-00527	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33978	16041-20000-35358	222 W 6TH ST 6th flr	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Issued	12/14/2016 12:00:00 AM	ADDRESS	33.73887	-118.28305	plan check for energy and em lighitng only. Ti to the 5th floort in a commercial building.  adding new lighting new controls to existing panels.   total square footage 18146.Building appl# 16016-10000-23430	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33979	15041-20000-18238	10870 N ZELZAH AVE	91344	12	210B129   826	2712020001	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.26834	-118.5233	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (27) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33980	17041-10000-21247	8939 N WOODMAN AVE	91331	6	195B153   446	2639039015	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.23206	-118.43824	T24 ONLY - REPLACEMENT OF EXISTING LIGHT FIXTURES WITH LED FIXTURES. TOTAL AFFECTED AREA =  6750 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33981	17041-30000-29945	6908 S KNOWLTON PL	90045	11	102B173   275	4103013104	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	33.97461	-118.37115	Plan check for new Fire alarm system on 3 story 18 unit appartment. Total Fire alarm devices: 138 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33982	14041-20000-28543	15936 W LONDELIUS ST	91343	12	195B141   659	2672031008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.22924	-118.47968	Original approved plan set and permit under permit #14041-20000-27121 eaten by dog. Re-plan check PV system to produce new set of approved plans and permit.PV1Install roof-mounted solar array on SFD. System size: 3.87kW.(18) EnPhase M215-IG microinverters(18) SolarWorld Poly SW 250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33983	15041-20000-25961	10247 N PLAINVIEW AVE	91042	7	204A197    83	2558033016	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	34.25548	-118.29803	Plan check for Title 24 only in exiting office space. Total indoor area: 589 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33984	13041-10000-17730	9427 N HANNA AVE	91311	12	198B101   139	2727019044	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.24156	-118.60832	PV1.  Installation of roof-mounted 4.32 kW AC solar array, interconnect with main service panel. {Microinverters: Enphase M215-60-2LL-S22} {20 modules: REC 250 PE}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33985	09041-10002-05908	1460 N VINE ST	90028	13	147A189    91	5546025015	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM			PC Approved	05/11/2010 12:00:00 AM	ADDRESS	34.09734	-118.32646	Changes of T-24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33986	11041-20000-07510	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM			PC Approved	05/20/2011 12:00:00 AM	ADDRESS	34.08363	-118.32191	TI work As built drawings, plan check only.  Permit is existing.  Plan check requested per inspector.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33987	15041-20001-39997	6858 N MAMMOTH AVE	91405	2	183B157   787	2216025051	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	34.19551	-118.43221	Expedited plan check fee per customer request.  PV2. Install roof mounted PV system sized 13 kW. Interconnectd with main service panel.(40) SunPower 327W Modules(2) SMA inverters: SMA 7.7 and SMA 3.8	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33988	11041-10000-10258	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	title 24 for an existing restaurant. and e- lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33989	16041-10000-32490	10129 W ELKWOOD ST	91352	2	189B181   565	2405014009	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.05	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM			Corrections Issued	09/13/2016 12:00:00 AM	ADDRESS	34.21139	-118.35107	PV INSTALLATION OF 6.82 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(22) MODULES: LG 310 MONOCRYSTALLINE (22) MICROINVERTERS: ENPHASE M250	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33990	14041-10000-09420	223 E 111TH PL	90061	8	087A205    30	6073018020	R2-1	South Los Angeles	Southeast Los Angeles			2411.10	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	33.93404	-118.27082	P V1 ROOF MOUNTED TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
33991	16041-30000-00525	127 S SAN VICENTE BLVD Street-level	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	Plan check for power and energy.  Total area = 2,657 sq. ft.   T.I. to existing commercial highrise space.  410 A new load.  Equipment and feeders to remain existing.  New lighting,  receptacles, appliances, and HVAC.  Interior alteration at ground level including relocation of the mail room and lactation room, convert storage room to office and lounge area, no change in use.       Building is part of a medical campus but no health care area is included in scope of work.Building permit #15016-30000-25376	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33992	13041-20000-19493	3283 N HUTTON DR	90210	5	159B153   324	4382033007	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.12814	-118.4327	PV1 MICROINVERTER. TOTAL SYSTEM SIZE: 9.288 KW. 43 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33993	14041-10001-33120	6381 W HOLLYWOOD BLVD	90028	13	148-5A187 157	5546005010	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM			PC Approved	03/31/2015 12:00:00 AM	ADDRESS	34.10177	-118.32913	REVISION TO AN APPROVED SET OF PLANS. REVISIONS TO THE EGRESS LIGHTING ON BASEMENT AND FIRST FLOOR. REVISION NOTED DELTA-2.Full plan check for an assembly  to a change of use from bank to night club. Total area 7125 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33994	14041-20001-05233	5825 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97372	-118.41985	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33995	15041-20000-17845	20528 W HACKNEY ST	91306	3	192B109   526	2780022020	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.22237	-118.58079	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. (30) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
33996	16041-10000-35094	21224 W PROVIDENCIA ST	91364	3	168B105   290	2167011036	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.15875	-118.59425	ROOFTOP MOUNTED PVPV1 SFD TOTAL SYSTEM SIZE 11.2KWdc / 10.0KWac USING 40 MODULES IN TOTAL. USING MICROINVERTER SYSTEM ENPHSE M250.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
33997	16041-10000-14061	16101 W VENTURA BLVD STE 130	91436	5	168B141   539	2260023057	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM			PC Approved	04/21/2016 12:00:00 AM	ADDRESS	34.15658	-118.48382	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM BEAUTY SALON TO OFFICE SPACE. SCOPE INCLUDES NEW RECEPTACLES FOR OFFICE SPACE. NO LIGHTS BEING INSTALLED FOR OFFICE. NOTE: PERMIT PAID UNDER PCIS#16041-90000-13207	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
33998	14041-10000-16876	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			06/25/2014 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.04166	-118.26677	Plan check for power and lighting.  Total area = 1,190,061 sq. ft.New high rise multi-use project with 9 floors of parking, retail on the ground floor, and two 36 story towers accomidating 652 residential units. Major design changes have been made, created supplemental. ALL PERMIT FEES ARE CHARGED ON MASTER APPLICATION UNDER INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
33999	11041-20000-26229	8930 N VILLAGE AVE	91352	2	195B177   265	2404001006	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley	YES	1021.01, 1021.02	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.23076	-118.35614	New fire alarm for Village Christian School.   Fire alarm includes one panel and 8 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34000	18041-20000-00041	10880 W WILSHIRE BLVD ste 1100	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.05885	-118.44283	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34001	19041-20000-39665	7200 N DENNIS LANE	91307	12	183B093    87	2027012028	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.20095	-118.64008	PV1. INSTALL 12.80 KW DC PV SYSTEM WITH (40) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34002	16041-10000-12214	6570 S WEST BLVD 1-49	90043	8	102B185    90	4006020022	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			04/07/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	33.97915	-118.33503	NEW FIRE ALARM SYSTEM  FOR AN APARTMENT BUILDING. ONE FA PANEL 1 COMMUNICATION PANEL, 3 CONTROL PANEL AND 95 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34003	11041-10000-15034	541 S GLADYS AVE	90013	14	126A213    49	5147019018	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	34.04114	-118.24148	Existing seafood warehouse,  Per Inspector, Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34004	19041-20001-42031	17312 W SUPERIOR ST	91325	12	201B133   435	2755008005	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM			PC Approved	12/27/2019 12:00:00 AM	ADDRESS	34.24655	-118.51197	12-2-2019 Changes to an approved set of plan, changes include addition of sub-panel and revised load calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34005	13041-10001-32361	19041 W CELTIC ST	91326	12	210B121   615	2718011001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.2693	-118.54777	Expedited RSES plan check per applicant request.(((PV1, Install 9.25 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverters Solaredge SE5000A-US and Solaredge SE3800A-US . 37 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34006	13041-10001-17638	12875 W RUNWAY ROAD Units 1-6	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/20/2015 12:00:00 AM			PC Approved	02/23/2015 12:00:00 AM	ADDRESS	33.97528	-118.42029	2/23/2015 Changes to an approved set of plans. Changes include changes to a luminaire type and the addition of lighting controls to certain fixtures. All changes clouded and marked as Delta 9.*****Previous Work Description*****PLAN CHECK POWER AND ENERGY FOR NEW 6-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #4  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34007	17041-20000-11070	3560 S WATT WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.02169	-118.28671	ti to an existing pool house.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 8192.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34008	18041-10000-12451	718 S HILL ST	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.04527	-118.25477	PLANCHECK FOR POWER AND ENERGY. CORE AND SHELL RENOVATION FOR THE EXISTING 7-STORY BUILDING .BUILDING PERMIT: 18016-10000-03643	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34009	14041-20000-16376	4944 N HOOD DR	91364	3	171B113   537	2175020007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.16112	-118.56838	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.5 KW DC USING MICROINVERTERS ENPHASE M215. USING 39 MODULES. 8.3KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34010	18041-20000-04866	20701 W PLUMMER ST	91311	12	201B109   305	2748003071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.24287	-118.58449	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34011	10041-10000-09196	8941 N TAMPA AVE SUITE  #A	91324	12	195B117    25	2783028013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	12/16/2010 12:00:00 AM	ADDRESS	34.23285	-118.55413	Ti for a Sonoma Cafe. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34012	13041-20000-12175	16130 W ANOKA DR	90272	11	129B125   129	4420005019	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM			PC Info Complete	05/10/2013 12:00:00 AM	ADDRESS	34.05264	-118.53412	PV1 2-STORY SINGLE FAMILY DWELLING. STANDARD PLAN, TOTAL SYSTEM SIZE: 2.64 KW. [INVERTER: SUNNY BOY 3000-US] [SOLAR MODULE: TRINA SOLAR TSM-240 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34013	17041-10003-10065	12035 W WILSHIRE BLVD	90025	11	126B145    25	4265016043	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.04541	-118.46622	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include relocating EV chargers locations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34014	11041-10000-25949	10250 W SANTA MONICA BLVD Loading-Dock	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Expired	12/31/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	Plan check T24 Energy for new loading dock and path on Level B. Lighting connected to existing lighting control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34015	18041-20000-38176	3308 S MENTONE AVE	90034	5	120B161   102	4314022036	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			10/05/2018 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/07/2023 12:00:00 AM	ADDRESS	34.02849	-118.4115	Plan check for 15 units multi residential building 5 story, Total area: 6888  sq ft. B#17010-30000-04108Fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34016	14041-20002-23017	537 E VENEZIA AVE	90291	11	108B145  1638	4237003009	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Expired	04/11/2017 12:00:00 AM	ADDRESS	33.98952	-118.45973	CHANGES TO APPROVED SET OF PLANS. ADDITION OF A TRANSFORMER TO CONVERT THE VOLTAGE TO MATCH THE UTILITY.  NO OTHER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34017	18041-10000-00812	5950-5970 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	33.94286	-118.38591	Energy plan check for a storage building. Scope includes new lighting for an area of 3,800 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34018	15041-10001-43403	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	ADDRESS	34.03365	-118.24048	This is PC only, permit under master E#, changes to approved set undet Delta-1, changes on T-24 only.<<Full plan check for retail spaces at first level of a parking structure, owner build out. Newly connected load is less than 400 A.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34019	16041-20000-00846	13117 W CORCORAN ST	91340	7	216B161   331	2514017008	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.28716	-118.4188	Plan check for a PV1 roof-mounted PV system. System size is 6.5 kWac and consists of (26) modules, (26) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34020	19041-10000-51269	11223 N CARRILO DR	91345	7	210B145   529		P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.27423	-118.46861	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF CENTRAL INVERTER(SE3800H-US) WITH 9 MODULES USING P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34021	19041-10000-32017	110 W 9TH ST 8TH FLR	90015	14	127-5A209 274	5139002021	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04175	-118.25551	Energy plan check for a partial office T.I located on the 8th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 21,469-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34022	18041-20000-42220	8545 N HATILLO AVE	91306	3	192B113    95	2782016011	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Re-Activate Permit	10/21/2019 12:00:00 AM	ADDRESS	34.22574	-118.56523	install roof mounted pv system sized 16.258KW with Energy storage system size: 27kWh with 50 PV Modules and 2 inverters(10.0kW and 3.8kW), 2 Tesla PowerWall 2.0 13.5kW$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34023	10041-20001-25883	22142 W SHERMAN WAY	91303	3	183B101   109	2024012003	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Approved	05/12/2011 12:00:00 AM	ADDRESS	34.20073	-118.60949	Revision to approved plans. T24 Energy and lighting layout change.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34024	17041-10000-30356	12414 W EXPOSITION BLVD	90064	11	123B149   857	4259026002	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.03061	-118.45624	PC FOR FA SYSTEM IN OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34025	18041-20001-10395	120 N ROBERTSON BLVD	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.07585	-118.38356	08-16-18 Changes to an approved set of plan, changes include revised lighting fixture schedule on floor plan, Title 24 calculation, all changes has been clouded as delta 2. Plan check only. Permit covered under Master Application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34026	16041-20000-10374	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.0754	-118.38272	New roof top maintenance lighting on top of (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34027	11041-10004-06422	8500 W BURTON WAY	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	DELTA 4 CHANGES TO THE APPROVED PLANS.     New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34028	19041-20000-45182	2423 N BRIARCREST ROAD	90210	4	153B165   254	4388015005	RE20-1	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM	09/29/2020 12:00:00 AM		Issued	09/29/2020 12:00:00 AM	ADDRESS	34.11518	-118.39283	Plan check for a new 600A Service, relocating existing 22KW Generator on a Single Family Dwelling with all new panels and ckts on the floor plan.Note. all ckts fee are under building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34029	19041-10000-13493	9771 W GLENSIDE PL	90210	5	150B157    85	4384028011	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.10953	-118.4236	$0 permit fee per assembly bill 1414.pc for pv system. 11.4KW system. system includes (34) VBHN330SA17 modules W/P400 solaredge optimizer. (1) SE3800H-US inverter, (1) SE7600H-US inverter,  (1) LG Chem Battery. (2)125A load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34030	12041-20000-20936	2706 W WILSHIRE BLVD	90057	1	133-5A201  94	5141011016	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.06093	-118.28296	Plan check for power only. Replacement of 1600A and 800A services and other equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34031	15041-10001-17133	7402 S AGNEW AVE	90045	11	102B161   148	4110025035	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM			PC Approved	06/15/2015 12:00:00 AM	ADDRESS	33.97302	-118.40919	Expedite per applicant request.(((PV1 11KW Ac roof-mounted system with (35) Sunpower SPR-E20-327 modules, (1) SMA America SB5000TL inverter and (1) SMA America SB6000TL iverter inter connecting through the service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34032	15041-10000-06484	19401 W PARTHENIA ST	91324	12	195B117   188	2783027047	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Closed	08/02/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	PC FOR POWER. TEMPORARY POWER FOR ANEW COMMERCIAL BUILDING. 800 A DISTRIBUTION BOARD AND 6 SPIDER BOXES 100 AMPS.  ONE 100 AMPS FEED TO THE TEMP TRIALER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34033	17041-10002-05914	1830 N BRONSON AVE 1-81	90028	13	150A191   264	5586028026	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.10433	-118.31784	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 10. CHANGES INCLUDE REPLACING/RELOCATING LIGHTING FIXTURES, REVISING TITLE 24 CALCULATIONS, AND REVISING FLOOR PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34034	15041-20000-11107	12741 W VENTURA BLVD	91604	2	165B161  1006	2375021017	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.14491	-118.41084	Title 24 plan check only.  Total area = 3,084 sq. ft.T.I. to existing retail space.  Relocating existing main panel (225 A bus) and connecting two new subpanels to it.  Changes to lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34035	14041-10000-35676	12021 N LOUISE AVE	91344	12	216B129   115	2606027053	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.29018	-118.51296	PV1 9.75KW ground mounted system with (39) Rnesola JC25M modules and Enphase M215 microinverters interconnect through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34036	14041-10002-21294	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016023	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Public Safety Only			06/12/2015 12:00:00 AM			PC Approved	06/12/2015 12:00:00 AM	ADDRESS	34.08758	-118.34425	REVISIONS TO PERMITTED SET OF PLANS : RELOCATE MINIHORNS FROM LIVING ROOM TO BEDROOM IN ALL UNITS AND ADDED J-BOXESPLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34037	13041-10001-18601	8201 W BEVERLY BLVD STE300	90048	5	138B173   380	5514008046	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.07624	-118.36815	supplemental pc. original plans were lost.permit to be pulled at EPC counter only. PC for energy only with emergency lighting. less than 400A and not a hirise per applicant. suite 300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34038	17041-10000-14525	3426 S COCHRAN AVE	90016	10	120B177   859	5047010007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.02434	-118.3613	PC FOR PV SYSTEM RATED 3.8KW AC USING CENTRAL INVERTER SYSTEM AND POWER OPTIMIZERS. ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34039	10041-10000-24692	1201 E 8TH ST	90021	14	124-5A213 359	5146006014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM			PC Approved	12/13/2010 12:00:00 AM	ADDRESS	34.03493	-118.24462	T-24 lighting plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34040	10041-10000-13950	11021 W MCCORMICK ST	91601	4	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			07/20/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	01/05/2011 12:00:00 AM	ADDRESS	34.16608	-118.37101	Title 24 energy and emergency lighting for common area . previously approved , change of fixture and reduction of wattage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34041	11041-20000-05514	17934 W VENTURA BLVD	91316	5	171B129   269	2182001003	C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1395.02	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	08/26/2011 12:00:00 AM	ADDRESS	34.16386	-118.52332	PLAN CHECK T24 ENERGY/EMERGENGY LIGHTING FOR CHANGE OF USE FROM RETAIL TO RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34042	18041-20000-15071	19515 W NORDHOFF ST	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.23567	-118.55825	temp power for construction site, 600 amp service.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34043	14041-20001-09444	5955 N VANALDEN AVE	91356	3	177B121   670	2156008022	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.17878	-118.54992	(((EXPEDITE FEES)))PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34044	14041-10001-33784	16650 W SHERMAN WAY BLDG C	91406	6	183B137    70	2225005014	[Q]CR-1, [Q]CR-1VL, [Q]P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM			PC Approved	07/23/2015 12:00:00 AM	ADDRESS	34.2008	-118.49594	Change to approved set by upsizing the feeder for HL-1C to 600Kcmil and updating the manual transfer swith diagram. Note all changes are under delta-1 only.(((Renovation of (E) 2-story commercial office building.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34045	13041-10001-31962	359 S LA BREA AVE	90036	4	135B181   359	5508001031	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.06719	-118.34433	CHANGES TO APPROVED: REVISING SCOPE TO SHOW panel DP UNDER LANDLORD and loads decreased. Plan check for power and energy. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34046	12041-20000-10901	1445 N GARDNER ST PV1	90046	4	147B177  1071	5550025012	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Expired	06/26/2014 12:00:00 AM	ADDRESS	34.09743	-118.35302	6.27 KW SOLAR ROOF MOUNT 33 PANELS 1 INVERTERSolar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.Permit is express on 12041-10000-06184	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34047	16041-20001-29600	13931 W POLK ST	91342	7	228B153   451	2503006018	RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.31909	-118.43699	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.25 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34048	13041-20001-23841	7309 N HILLSVIEW CT	91304	12	186B089   540	2027047008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	PIN	34.20426695	-118.65176836	PV1 TRANSFORMERLESS SYSTEM. 25 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34049	16041-10001-16707	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Issued	05/31/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC FOR CHANGES TO APPROVED SET. REPLACING CONDUCTORS (REFEED) FOR MEDIUM VOLTAGE FEEDERS  34.5 KV PER INSPECTION.DELTA CHANGES UNDER 1A  AND 2F  new engineer and contractor assigned to finish work	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34050	18041-10000-12980	3411 N MANDEVILLE CANYON ROAD	90049	11	150B133    65	4491006006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM			Corrections Issued	04/10/2018 12:00:00 AM	ADDRESS	34.10623	-118.50288	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(29)MODULES-SOLARCITY SC325(29)OPTIMIZERS-SOLAREDGE SE7600A(1)INVERTER-SE7600A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34051	14041-20000-23112	24120 W HARTLAND ST	91307	12	183B089   617	2034027049	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.19481	-118.65072	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING MICROINVERTER SYSTEM. USING ENPHASE M250. TOTAL OF 32 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34052	13041-10000-05815	12451 N MCLENNAN AVE	91344	12	219B133   465	2609025045	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM			Reviewed by Supervisor	03/19/2013 12:00:00 AM	ADDRESS	34.29626	-118.5015	PV1 FOR SINGLE STORY HOUSE AS PER APPLICANT.  7.140 KW DC SYSTEM SIZE.  {28 MODULES: BOSCH SOLAR MODULE c-Si M 60 NA42117} {TRANSFORMERLESS CENTRAL INVERTER: AURORA POWER-ONE PVI-6000-OUTD}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34053	11041-10000-16667	10237 N TUJUNGA CANYON BLVD	91042	2	204B197  1029	2558022058	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	08/08/2011 12:00:00 AM		Permit Expired	08/30/2013 12:00:00 AM	ADDRESS	34.2528	-118.29122	REPLACE AN EXISTING OLD FIRE ALARM PANEL WITH A NEW ONE CONNECTEDTO EXISTING DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34054	12041-20000-09705	25 N OAKMONT DR guest hse	90049	11	135B137    64	4426022023	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2012 12:00:00 AM			PC Info Complete	03/25/2014 12:00:00 AM	ADDRESS	34.06938	-118.49075	guest house...... main house on application # 12041-20000-09527	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34055	19041-10000-12875	1320 E NEWTON ST	90021	14	121-5A213 102	5130011033	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.02746	-118.24664	NEW FIRE ALARM SYSTEM IN THE RED CROSS BUILDING WITH 86 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34056	16041-20001-20538	1778 W 36TH PL	90018	8	120B193  1463	5041023005	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Apartment			06/10/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.02178	-118.31126	Expedite per applicant request((((Plan check for PV roof mounted system. system size: 3.8kW with 15 modules and 1 inverter (3.8kW)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34057	12041-10002-23829	236 S LOS ANGELES ST	90012	9	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Closed	03/18/2015 12:00:00 AM	ADDRESS	34.04922	-118.24386	Construct 176-unit apartment with retail and basement garage. Variance is required to separate the FIRE ALARM plans...  ((((((((((((( VALUE ENGINEERING,    4000 AMPS FEEDER, TO AL.  ALL  METER SECTION TO 80 AMPS , ELEVATION. ETC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34058	15041-10000-42821	1401 N LONDONDERRY PL	90069	4	147B169   915	5559010012	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM			PC Approved	12/18/2015 12:00:00 AM	ADDRESS	34.09556	-118.38046	CHANGES TO AN APPROVED SET OF PLANS.  CHANGING 25 MODULES FROM SOLARWORLD SW275MONO TO SUNMODULE SW 280 MONO.  THIS IS PLAN CHECK ONLY.  FEES PAID UNDER APPLICATION NUMBER 15041-10000-03116PV1, 6.875KW DC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE(25)  MODULES (25)MICRO INVERTER ENPHASE M250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34059	18041-20000-26702	10250 W CONSTELLATION BLVD ste 850	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	ti to an existing high rise building.  adding new lighting new controls to existing panels.  plan check for energy only. suite 850.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34060	17041-20000-03617	6727 W FRANKLIN PL	90028	13	150A185   303	5547001018	[Q]R4-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.1042	-118.33719	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING. 11,936 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34061	15041-20000-10538	16450 W FOOTHILL BLVD	91342	7	228B137   183	2603007036	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.31882	-118.48831	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 244KW DC(6) SOLECTRICAL PVI 28TL(1) SOLECTRICAL PVI 23TL(799) CANADIAN SOLAR CS6X-305PZoning clearance approved from building permit.Note: Permit fees are $0.00 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34062	11041-10001-05073	7238-7248 N CANBY AVE	91335	3	186B125   921	2119021032	(T)[Q]R4-1-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM			PC Approved	02/22/2013 12:00:00 AM	ADDRESS	34.20236	-118.5346	CONSTRUCT A NEW 3 STORY, WOOD FRAMED 98 UNITS APARTMENT BUILDING OVER AN ON-GRADE CONCRETE PARKING STRUCTURE.  EPC IS FOR POWER & ENERGY.((((((((((( CHANGES MADE TO PREVIOUSLY APPROVED SET , SER CALES ROUTED AND GROUPED TOGETHER. 2-15-13))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34063	17041-10000-28381	20037 W VENTURA BLVD	91364	3	174B113   423	2166001032	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.17166	-118.56958	REMOVE HID  FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY.Total affected area 19775 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34064	19041-20000-53704	8951 W ST IVES DR	90069	4	144B169   227	5560017017	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.09334	-118.38754	PV1. INSTALL 11.34 KWDC AND 10 KWAC ROOFMOUNTED PV SYSTEM WITH (36) MODULES, OPTIMIZERS AND (1) INVERTER (SE11400)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34065	16041-10000-15364	18350 W HATTERAS ST 101-184	91356	3	174B125    27	2157015***	(Q)RD1.5-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.17721	-118.53258	PV2, ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS, TO AN APARTMENT UNIT. TOTAL SYSTEM SIZE: 64.5 KW. PV MONITOR SYSTEM INCLUDED. (300) TRINA SOLAR MODULES, (300)  ENPHASE M215 MICROINVERTERS WITH 3 SUBPANELS.NOTE: FEES ARE $0 DUE TO SENATE BILL 12222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34066	15041-20000-14395	6252 N TOPANGA CANYON BLVD F-1695	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.18504	-118.60554	Plan check for power and Title-24.  Total area = 919  T.I. for restaraunt first time tenant.  New lighting and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34067	18041-10001-22556	333 S HOPE ST 31ST FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Info Complete	10/10/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	DELTA CHANGES TO APPROVED PLANS FOR REMOVING FURNITURE LIGHTS FROM INDIVIDUAL OFFICES ON 31ST FLOOR.PLAN CHECK ONLY. ELECTRICAL PERMIT WAS ISSUED UNDER: 18041-10000-22556<<<Plan check for Power and Energy on (E) office. TI with new loads >400A, total area: 22,907 sq.ft(B# 18016-10000-17788)>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34068	12041-10000-16141	14537 W ARCHWOOD ST	91405	6	180B149   115	2236009008	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.19306	-118.45004	central station , one panel, 2 devices, two story mixed use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34069	13041-10000-35928	777 E 10TH ST STE #112	90021	14	124-5A211 244	5132002041	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.03437	-118.24974	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 1140 SQ FT. TOTAL OF (4) UNITS WILL BE REPLACED. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34070	16041-10000-15972	5271 W JEFFERSON BLVD	90016	10	120B177   699	5043024003	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.02564	-118.36055	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR RESTROOM AND GENERAL COMMERCIAL SPACE. TOTAL AFFECTED AREA IS 5958 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34071	14041-20000-34078	3573 N DIVISION ST	90065	1	151-5A219 284	5462028007	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.10771	-118.22368	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (22) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34072	16041-30000-11802	129 S KINGS ROAD	90048	5	138B173   707	5511015022	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.07355	-118.37236	Installation of fire alarm system in new 36 unit 4 story apartment building.  Total system size = 141 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34073	13041-10000-23169	2649 S TILDEN AVE	90064	5	123B157   811	4256018026	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.03257	-118.42998	PV1 9.55KWdc 240V XFMR(-)INV. 1STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V7.5][( 39) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34074	18041-10000-28701	15350 W NORDHOFF ST B	91343	7	195B145   652	2654004050	[Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			Corrections Issued	07/31/2018 12:00:00 AM	ADDRESS	34.23519	-118.46701	PC APPROVED WITH PERMIT UNDER 18041-10000-19009THIS APPLICATION IS VOIDPC FOR T-24 ENERGY ONLY FOR INTERIOR RENOVATION FOR RETAIL STORE (T-MOBILE). SCOPE INCLUDES NEW PANEL LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA 1910 SQ.FT. B#18016-10000-16172	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34075	10041-20000-16375	2640 N ROSCOMARE ROAD	90077	5	156B145    34	4378014010	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2010 12:00:00 AM			PC Approved	11/10/2010 12:00:00 AM	ADDRESS	34.12652	-118.46233	PLAN CHECK FORE NEW SINGLE FAMILY DWELLING WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34076	15041-10000-17696	18711 W SHERMAN WAY	91335	3	183B121   100	2118026019	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.20128	-118.54074	FULL PLAN CHECK TO A NEW 30 UNIT( 5 TYPICAL) 4-STORY MULTI-RESIDENTIAL BUILDING. PC FOR ENERGY AND POWER. 1200 AMP SERVICE, TOTAL SQ. FT. 22629.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34077	17041-10000-09761	10050 N SEPULVEDA BLVD	91345	7	204B145   796	2660010901	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.25294	-118.46711	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 22850 SQ. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34078	18041-10002-04570	800 S LA BREA AVE	90036	4	132B181   271	5084003001	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.06027	-118.34454	Change to an approved set by relocating kitchen equipment and panels in the mezz' area. All changes under delta-25 only.(((Full plan check for change of use on (E) Historic Building. Change of use from autoshop to microbrewery.  New service at 800A, new panelboards, total area under the scope: 9,845 sq.ft B#18016-10000-05359.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34079	17041-10000-05702	8730-8740 1/2 S BELFORD AVE BLDG. #4	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Closed	05/29/2020 12:00:00 AM	ADDRESS	33.95736	-118.3838	PC FOR POWER ONLY FOR A NEW 600A 120/208 1 PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD, AND NEW SUBPANELS. SERVICE IS FOR AN EXISTING 12 UNIT TENANT SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34080	15041-10001-24619	6000 W PICO BLVD	90035	10	129B173   338	5068011006	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.05223	-118.3713	Changes to approved set. PC remains for energy only.Change of engineer on record ( to design/built)Changes include new equipment and new receptacles Also changing luminaire type.Total new proposed load is still <400A.T-24 TO AN (E) BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING INDOOR/OUTDOOR AND POWER. CONNECTED LOAD <400AMPS. TOTAL SQ. FT. 4887.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34081	15041-20003-08533	6344 N TOPANGA CANYON BLVD #1050	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	"Changes to an approved set of plans. Delta 3 changes. Changing 65W light fixture with 50W.(((Plan check for power and energy for first time tenant (new restaurant = Tender Greens). Total area: 3177 sq ft. Part of Building A of ""Westfield Topanga"" mall.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34082	15041-20000-09442	6238 N COLDWATER CANYON AVE	91606	2	177B161   242	2332003004	RD2-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.18416	-118.41357	Installation of new solar PV array.  Total system size = 4 kWac.  Microinverter system with 1 branch circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34083	12041-20000-14553	902 E 59TH ST	90001	9	105B209    37	6007004004	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM			Reviewed by Supervisor	08/09/2012 12:00:00 AM	ADDRESS	33.98705	-118.25942	New commercial building with 1200A service for Core and Shell.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34084	15041-10000-28215	815 N LAS LOMAS AVE	90272	11	129B121   508	4420010003	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.04915	-118.53839	PV 1 Installation of  a new roof mounted solar system to a residential home. 20 microinverters Emphase enrgy M215-60-2ll-ig. (20) modules: lg electronics lg-270-sic-g4.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34085	15041-20001-12893	8412 N MELBA AVE	91304	12	192B093   140	2005013007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM			PC Approved	05/09/2015 12:00:00 AM	ADDRESS	34.22247	-118.63521	PV1Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.7kW. Ungrounded system. (30) 275W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34086	15041-10000-36937	610 W 41ST ST	90008	9	115-5A201 349	5019019015	RD1.5-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	PIN	34.00846638	-118.28452145	PV1INSTALL ROOF MOUNTD PV SYSTEM SIZED 8.2KW INTERCONNECTED WITH MSP.(40) MODULES(1) PVI 8200 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34087	13041-10002-19659	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			01/23/2015 12:00:00 AM			PC Approved	03/13/2015 12:00:00 AM	ADDRESS	34.09918	-118.32644	(((((    m.zandi,  1-22-15 Following changes have been made: Reduced unit panel OCPD to 100A, changed unit panel feeders to Aluminum, reduced three unit panel panel distribution boards' OCPD to 1200A. )))))   POWER AND ENERGY PLAN CHECK 287 UNIT APARTMENT BUILDING WITH FUTURE RETAIL SPACES. 7 STORY  LOW RISE BUILDING. VARIANCE TO SEPERATE FIRE ALARM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34088	19041-30000-33759	8525 W PICO BLVD	90035	5	132B173  1243	4332028039	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.0537	-118.377	Installation of 20 EV chargers. (12) 32amp and (8) 16 amp ev chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34089	12041-10000-10454	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	Install outdoor bollard lights for new walkway.  Plan check only for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34090	10041-10000-11356	3115 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035010	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.02984	-118.37443	tenant improvement in a commercial building-plan review was approved and permit was obtained  on09041-30000-022246.  new set of plans has changes in the power and lighting plans,plan chk is for title 24 and 1 ea emergency ckt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34091	10041-10000-04538	1630 N MAIN ST Bldg 15	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	05/14/2010 12:00:00 AM		Permit Finaled	05/16/2012 12:00:00 AM	PIN	34.06623967	-118.22749482	Installation of an exterior  50 KW Photovoltaic sytem.   The moudules are installed on the roof  of  buidling 15 as shown on the area plan.  The system includes a 50 KW -  3 phase Inverter, 13 strings of  13 modules each, one combiner box suitable for the connection of 24 strings, an AC disconnect switch, and one service disconnect switch.  The system is grid tied, but supplies no other load except the DWP pole mounted transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34092	14041-20000-21618	2392 N PANORAMA TER	90039	4	148-5A205  87	5432010010	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.10264	-118.27079	New roof mounted PV system with Optimizers.  Total system size 4.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34093	15041-10000-03327	1581 E INDUSTRIAL ST	90021	14	124-5A215  35	5164010002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM			PC Info Complete	04/21/2015 12:00:00 AM	ADDRESS	34.03608	-118.23629	Plan check for power and energy. Project site is an existing building (no change of use). Project includes a service upgrade to 800 amps, the installation of the main switchboard, (4) panel boards, and associated loads. Total lighting area = 9,630 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34094	13041-20000-34554	6358 W NANCY ST	90045	11	102B165   226	4110011016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	33.97673	-118.39828	PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 4.16KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34095	18041-10000-37588	19191 S VERMONT AVE 10TH FLR	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLAN CHECK FOR TITLE 24 ONLY FOR - 10TH FLOOR CORRIDOR, ELEVATOR LOBBY AND RESTROOM RENOVATION ON APPROX 984 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34096	19041-20000-15998	12575 W VENICE BLVD	90066	11	111B153   336	4246027001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Apartment			05/09/2019 12:00:00 AM	04/23/2020 12:00:00 AM		Permit Finaled	05/25/2022 12:00:00 AM	ADDRESS	34.00268	-118.43627	Plan check for power and energy for multi-family building,  1600A service 120/208volt, Total area: 175,192 sq ft. 8 typical units. B#19010-10000-00835	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34097	17041-20000-10580	11371 W RIVERSIDE DR	91602	4	168B173   525	2353028071	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.15729	-118.37833	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to massage parlor/tenant improvement. Total lighting area = 1,382 sq. ft.Note: Building permit has been pulled under 16016-20000-28128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34098	12041-20000-28235	5160 N VINELAND AVE 101A-101B	91601	4	171B173  1378	2419001042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.16418	-118.37009	Change to lighting in an existing retail space.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.  No emergency lighting is part of this plan check.  Permit fee for 2 new circuits are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34099	17041-10001-13159	606 N BONNIE BRAE ST	90026	13	138A207   192	5404010017	RD1.5-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	ADDRESS	34.07222	-118.2642	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling with 5.8 kVA battery backup.  Central inverter system.  Total system size = 3 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34100	12041-10000-03844	145 S SPRING ST	90012	9	130-5A213  30	5149001003	C2-4D	Central	Central City	Downtown Los Angeles		2073.00, 2074.00	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.05196	-118.24563	Plan check for new 2000A switchboard, 400A switchboard , ATS, and equipment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34101	13041-20000-11860	777 S FIGUEROA ST 3RD FLOOR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.04828	-118.26116	T24 FOR EXSITING OFFICE SPACE IN HIGHRISE BUILDING. SCOPE OF WORK LOCATED ON THE 3RD FLOOR. 15450 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34102	18041-20000-12883	16501 W VENTURA BLVD Suite 504	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.1578	-118.49275	Plan check for Title 24 only in existing high-rise building T.I. office Building. New lights, existing circuits. Total area: 7,039 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34103	17041-10000-33557	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007927	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Info Complete	03/19/2018 12:00:00 AM	ADDRESS	34.1504	-118.32742	PC for power for new 4800V to 480/277V outdoor unit substation and 480/208V indoor unit substation. Connecting new 400A distribution board and reconnecting exisiting equipment to new system. Replacing two medium voltage 100A fuses with two 200A fuses.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34104	14041-20000-11298	6255 W SUNSET BLVD SUITE 2200	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	TI for high-rise commercial office building on 22nd floor.  Plan check for Title 24 for changes to lighting system only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34105	12041-10000-18574	900 S FIGUEROA ST Ground	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			08/08/2012 12:00:00 AM			PC Approved	08/08/2012 12:00:00 AM	ADDRESS	34.04604	-118.26272	Plan check for energy and emergency lighting. 4222 sqft. High rise apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34106	12041-10000-18101	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010		Harbor	Wilmington - Harbor City		YES	2951.01	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	33.77884	-118.29327	Install a new 10HP Motor, lighting, at an existing refinery in a classified area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34107	13041-10000-29719	1660 W ANAHEIM ST	90731	15	030B201   315	7412022010	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	New fire alarm system in newly constructed 2-story office building.  1 FACP and 2 graphic annunciators.  173 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34108	19041-10000-06474	9443 N HASKELL AVE	91343	12	198B141   137	2671027001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.2421	-118.47644	PC FOR PV SYSTEM. (24) MODULES (TRINA SOLAR TSM-280DD05A.05). (24) OPTIMIZERS (SOLAREDGE 320). (1) SOLAREDGE INVERTER (SE6000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34109	14041-20001-30427	13507 W RANGOON ST	91331	6	195B157  1022	2627003015	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	34.22801	-118.4267	Supplemental application for restamp of lost plans.PV1Install a roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 4.3kW.2 strings of 20 M215 microinverters connected to 20 250W pv modules (10+10).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34110	19041-10000-10887	1515 W 190TH ST STE 550	90248	15	060B193   385	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	Energy plan check for an office T.I located on the 5fh floor of a 5-story commercial building, Scope includes new lighting and equipment with a total area of  2826-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34111	17041-10000-09505	357 S CURSON AVE WEST GARAGE #2	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.06858	-118.35526	PC for energy only, outdoor only. Removing HID fixtures and replacing them with new LED ones. Area: 24,775.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34112	14041-10000-21294	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016023	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.08758	-118.34425	Installation of a complete, non high rise, code minimum, addressable fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34113	13041-10001-33047	9154 N HADDON AVE	91352	6	198B165   337	2629014113	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.23576	-118.40172	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34114	14041-20000-21610	8033 N DARBY AVE	91335	12	189B125   242	2102003015	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.21663	-118.53355	Roof mounted PV system with system size 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34115	11041-20000-25489	7800 W SUNSET BLVD	90046	4	147B177  1001	5551025025	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	12/28/2011 12:00:00 AM	ADDRESS	34.09789	-118.35952	T-24 lighting compliance for new pole mounted luminaire in bank parking lot, adjacent to ATM.  The installed power requirement for exterior lighting was not required to comply with Section 147.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34116	16041-10000-15457	10749 N SEVENHILLS DR PV1	91042	7	207B197   639	2553001001	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.26413	-118.28812	Add (2) modules to (E) PV1 system under E# 15041-10000-14078. System size remains the same.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34117	14041-20000-02596	12811 N FENTON AVE	91342	7	222B161   436	2525024032	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.30217	-118.413	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34118	14041-10000-26664	4401 W SUNSET BLVD	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.09708	-118.28526	Plan check for power and energy. Tenant improvement of existing church. 1 story. Area = 22344 sq. ft. note to engineer, all fee provided by applicant, plan checker needs to verify the fee for plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34119	17041-10000-04263	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Issued	02/09/2017 12:00:00 AM	ADDRESS	34.05048	-118.25755	T-24, PC FOR ENERGY ONLY. T.I. INTERIOR SPACE(CNP NORTH LOBBY). REPLACE EXIT DOORS AND NEW FOLDING DOORS. TOTAL AFFECTED AREA IS 6080 SQ. FT. B#16016-10000-30720	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34120	13041-10000-03516	7300 N EASTHAVEN LANE	91307	3	186B089   606	2027022033	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.20373	-118.64676	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. 2 STORY DWELLING. TOTAL SYSTEM SIZE 7.35KW. TOAL OF 30 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34121	18041-10001-16403	10250 W SANTA MONICA BLVD # 2060	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM			PC Approved	11/07/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC for DELTA 4 ONLY - Scope includes  Adding 1 sump pump only in janitor area and modify restroom receptecles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34122	15041-10000-21565	356 W 7TH ST	90731	15	015B201   162	7455012023	CM-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	33.73797	-118.28478	T-24 TO AN (E) CAFE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL SQ. FT. 2873. FEES WERE PAID UNDER APP# 14041-40000-33674.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34123	19041-20000-16620	7700 N JUSTIN CT	91304	12	189B093   763	2014032033	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.21033	-118.63136	Plan check for PV roof mounted system, System size: 12.47KW AC,  13.20KW DC with 40 PV Modules and 1 inverter(11.4KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34124	16041-20000-13904	3470 S TROUSDALE PKWY #1100	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM			PC Approved	04/21/2016 12:00:00 AM	ADDRESS	34.02202	-118.28393	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to Suite 1100. Total lighting area = 764 sq. ft.Note: Building application has been generated under 16016-10000-06646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34125	15041-10000-16119	3343 W 43RD PL	90008	10	114B185  1207	5024019006	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM			Corrections Issued	05/27/2015 12:00:00 AM	ADDRESS	34.00442	-118.33116	TI to convert six (E) retail spaces into three retail spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34126	17041-30000-28178	1800 S AVENUE OF THE STARS STE675&685	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Issued	08/10/2017 12:00:00 AM	ADDRESS	34.06095	-118.41786	Plan check for Title 24 only in existing high-rise office High rise. Total area: 4435 sq ft. Building application number: 17016-10000-18930	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34127	14041-10000-05353	614 TERMINAL WAY	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	PIN	33.74709654	-118.26797053	PLANCHECK FOR POWER. ADDITION OF REEFER OUTLETS FOR REFRIGERATED CONTAINERS IN PORT OF LA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34128	13041-10000-04830	20746 W HORACE ST	91311	12	207B109    93	2706009010	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.26701	-118.58594	PV1 single story home. Total system size 7.92 KW. [Inverter: Sunny Boy. Model#: Sunny Boy 7000-US] [Solar Module: TrinaSolar. Model#: TSM-240 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34129	15041-20001-21918	8527 W FOOTHILL BLVD	91040	7	207B189  1072	2555033013	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			PC Approved	04/26/2016 12:00:00 AM	ADDRESS	34.2599	-118.31882	4.26.2016 - Plan check for modifications to approved set. Add symbols for photocells and show them on the floor plan. Remove panel DP and feed Panels A, B, and C directly from switchboard MS. Panel A is now 2 sections/enclosures (with feed through lugs). Home-runs updated to reflect adjusted circuit positions (circuit positions maintain disaggregation per original approved set of plans).====Plan check for power and energy for existing restaurant T.I. Service upgrade from 1phase 600A to 3 Phase 600A with new service equipment and panels. Total indoor and outdoor area: 1,770sqft and 1,575sqftCOMPLY WITHDEPARTMENT ORDER effective date 08/27/2015. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE. All permits shall be for the same timeperiod limitation. If additional assistance is needed, pleasecall Inspector DUANE JOHNSON at (213)252-3947.  CEIS Case Numberis 693507	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34130	17041-10000-42874	5251 W IMPERIAL HWY	90045	11	087B173   142	4129038001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	33.93108	-118.37125	PC FOR T-24 ONLY FOR SIGNAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34131	18041-20001-00086	14071 W TYLER ST	91342	7	228B153   274	2503019002	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Issued	02/08/2018 12:00:00 AM	ADDRESS	34.32211	-118.44022	02/08/2018 No fee. Department error. Change of work description: PV1.  Installation of a 9.976 kWac roof mounted grid tied PV system.  String inverter standard plan.*****Previous Work Description*****PV1.  Installation of 11.2 kW DC roof mounted grid tied PV system.  String inverter standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34132	11041-10000-27547	885 S PIER A ST	90744	15	021B205   167	7440018905	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	33.75438	-118.27117	Plan check power in hazardous area.  New 15KVA transformer, panel board, and two 100A rated receptacles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34133	16041-10000-19721	4151 W PROSPECT AVE BLDG #A-LWR LEVEL	90027	4	148-5A201 583	5591021014	[Q]M1-1, D	Central			YES	1952.00	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON BUILDING A LOWER LEVEL. SCOPE INCLUDES NEW LIGHTING FOR AN EXISTIN OFFICE SPACE. TOTAL AFFECTED AREA IS 2280 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34134	15041-10000-19138	2101 S LOUELLA AVE	90291	11	111B149   713	4242022014	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	33.99996	-118.45127	PV 1, ROOFTOP MTD. (26) MODULES, (1) 5KW AC INVERTER,  AND (1) , COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34135	17041-20000-30154	4095 S REDWOOD AVE	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	33.99101	-118.44065	TI to (E) commercial office space.  3,166 sq ft - plan check for energy only. Building permit issued under 17016-10000-22857	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34136	15041-10000-10304	1038 S MARIPOSA AVE	90006	1	129B197   387	5078016047	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			04/07/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.05151	-118.2988	New fire alarm for a new 5-story apartment building; scope includes (1) fire alarm panel, (1) annunciator, (2) power supplies, and (100) fire alarm devices..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34137	10041-10000-16373	515 S FIGUEROA ST 7TH FL	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	TENANT IMPROVEMENT IN OFFCESPLAN CHK IS FORT ITLE 24 PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34138	13041-20000-34722	6260 E TIPTON WAY	90042	14	159A231   120	5482001018	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.13098	-118.18413	New rooftop PV System for an existing SFD.  System is UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34139	18041-20000-17728	3010 N SIERRA ST	90031	1	141A225   184	5209002016	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.08078	-118.20146	Plan check for PV roof mounted system, system size: 3.3kW with 10 modules and 1 inverter(3.3kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34140	14041-10000-04567	1458 S SAN PEDRO ST #L-07	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	"PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 435 SQFT. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34141	19041-20000-33503	3490 N LA SOMBRA DR	90068	4	159B181   232	5579021032	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.13293	-118.34124	PV1.  Install 14.4 kW AC roof mounted grid tied PV system.  (40) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34142	15041-10000-37105	18957 W VENTURA BLVD	91356	3	174B121   406	2163020019	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.17263	-118.54646	PC FOR ENERGY. TI FOR T-MOBILE STORE. TOTAL AREA 1430 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34143	15041-10003-34860	7843 N LANKERSHIM BLVD	91605	6	189B169   517	2310025034	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.21329	-118.38805	DELTA 3 CHANGES TOTHE APPROVED PLANS. CHANGES INCLUDE MODIFYING LIGHTING PLAN AND NEW CIRCUITS ADDED. BUILDING PERMIT #15010-10000-03727COMMERCIAL APPLICTION # : 15041-10000-35250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34144	18041-20000-31884	16421 W CHATSWORTH ST	91344	12	207B137   390	2680013044	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	PIN	34.26504252	-118.4900825	Plan check for a PV1 roof-mounted PV system. System size is 3.9 kWdc and consists of (1) 3.8 kWac rated inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34145	19041-20000-25372	7721 N HASKELL AVE	91406	6	189B141   262	2206011035	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM			Reviewed by Supervisor	07/31/2019 12:00:00 AM	ADDRESS	34.211	-118.47511	Plan check for power and energy for change of use from Warehouse to Maufacturing Facility(hazardous Location). Existing 800A Service.  Total area: 23,390 sq ft. B#19016-20000-14600	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34146	15041-10000-29607	800 W WILSHIRE BLVD STE. 630	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.0493	-118.25841	Tenant improvement, canging light fixture to LED, new receptacles. PC for Energy only, total area: 1476 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34147	15041-10000-10014	14600 W SHERMAN WAY	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.20095	-118.45113	REPLACE EXISTING FIRE  ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34148	14041-20000-08321	2827 N ROSANNA ST	90039	13	150A211   193	5442031037	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.10543	-118.24894	PV1.  Install 1.35 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverter: Enphase M215.  5 modules: Plus SW 270	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34149	15041-20000-32156	6630 W SUNSET BLVD	90028	13	147A185    75	5547024006	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Apartment			10/23/2015 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/02/2020 12:00:00 AM	ADDRESS	34.09782	-118.33424	Plan check for power and energy. Project site is a new 6-story, mixed-used apartment building. Building is 5 levels of residential (40 units) over 1 level of retail, with 2 levels of underground parking. Underground service size is 3000 Amps. Total indoor lighting area = 38,810 sq. ft. and total outdoor lighting area = 1,542 sq. ft.Note: Building application has been filed under 13010-10000-01079	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34150	15041-10000-05695	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011065	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.98179	-118.40283	New fire alarm system for a commercial building(bld-1); work includes (1) fire alarm panel, and (14) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34151	17041-20000-23281	9958 N ETON AVE	91311	12	204B105   794	2747007056	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.25177	-118.59498	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.21 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34152	18041-20001-23094	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.08901	-118.34188	09/13/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta F. Entire lighting system has been changed from an AC lighting system to a DC lighting system, including EM lighting. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Plan check for power and energy change of use from part of office building to Medical Clinic 4th, 5th, and 6th Floor. T.I. to existing service equipment. Total area: 47,413 sq ft. B#18016-20000-15553	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34153	16041-10000-11833	10211 N TUJUNGA CANYON BLVD	91042	7	204B197  1137	2568009021	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.25165	-118.29114	PC  for POWER AND ENERGY. NEW 2-STORY 12 UNIT APT BLDG W/ON GRADE PARKING, BUILDING B.  THIS PLAN INCLUDES T24 FOR THE PARKING AREA FOR BUILDING A (16041-10000-11849), 8 UNITS APARTMENT BUILDING. TOTAL AREA 17542 SQ FTB# 13010-20000-02107	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34154	14041-10000-05147	3113 W SAN FERNANDO ROAD	90065	13	153A213    22	5458008014	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.1152	-118.24593	REMODEL EXISTING RESTAURANT-WABA GRILLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34155	17041-20000-42813	6221 N FALLBROOK AVE	91367	3	177B097   248	2039013060	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Apartment			11/28/2017 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.18316	-118.62362	new apartment building 1600amp service.  plan check for power and energy.building application number 17010-20000-04685	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34156	19041-10000-47052	384 WORLD WAY SPACE M51	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			Verifications in Progress	03/10/2020 12:00:00 AM	ADDRESS	33.94339	-118.40887	FULL PLAN CHECK FOR A FIRST TIME TENANT IN LAX. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE LOADS. TOTAL SQ FT 634. PROJECT #5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34157	13041-10000-20372	21933 W VENTURA BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Info Complete	07/31/2013 12:00:00 AM	PIN	34.16940578	-118.60503747	pc for energy only. with emergency lights. 2 storiesDIVIDE EXISTING SPACE AND ADD SWITCHES. plan check per inspector's request. permit already pulled under 13041-90000-18485	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34158	16041-20000-05960	5201 W 20TH ST	90016	10	126B177   953	5063001014	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			02/19/2016 12:00:00 AM			Reviewed by Supervisor	03/03/2016 12:00:00 AM	ADDRESS	34.04046	-118.35441	Plan check for PV roof mounted system on Appartment Building. System size: 3.8kW with 10 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34159	14041-20000-04370	7531 N ENFIELD AVE	91335	3	186B129   405	2120023007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.20744	-118.52418	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.6KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN. TOTAL OF 31 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34160	17041-20002-01429	8915 N WOODLEY AVE	91343	12	195B141   264	2688004017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM			PC Approved	03/09/2017 12:00:00 AM	ADDRESS	34.2325	-118.48529	[[[3/9/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES HAVE BEEN CLOUDED WITH DELTA 1. CHANGES TO THE MODULE LAY OUT. DERATING MAIN BREAKER TO 175 AMPS ]]]]]pv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34161	17041-10000-38362	1601 N GENESEE AVE	90046	4	147B177   623	5551014009	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.10007	-118.35842	FEE = $0.00 DUE TO SENATE BILL 12222PV1, INSTALL 53 NEW PV AC MODULES ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34162	14041-20000-34448	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM			PC Info Complete	12/12/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  CHANGING LIGHTING FIXTURES IN CORRIDORS IN 2 ND AND 6 TH FLOORS.  USE EXISTING CIRCUITS AND PANELS. TOTAL SQUARE FOOTAGE 2917.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34163	18041-10000-19451	15031 W ROMERO PL	91343	7	198B145   252	2651001***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.23838	-118.46002	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZER. (15) MODULES, (15) OPTIMIZERS AND (1) INVERTER. TOTAL SYSTEM SIZE IS 3.8KWAC AND 4.575KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34164	16041-10002-17596	423 W E ST	90744	15	030B205  1071	7418002013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	33.77548	-118.26697	pc for roof mounted pv plan check only for a lost approved setSystem size 5kwAC with 18 modules and optimizers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34165	12041-10000-20894	729 N AVENUE 66 1-4	90042	14	154-5A233   9	5493024008	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.02	Electrical	Electrical	Apartment			09/04/2012 12:00:00 AM	09/04/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.11962	-118.17506	tHIS IS A CENTRAL STATION FOR A TWO STORY RESIDENTIAL, FIRE ALARM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34166	15041-10000-27242	2236 S BARRINGTON AVE	90064	11	123B149   456	4260013027	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.03342	-118.44693	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD > 400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34167	15041-20000-12429	20500 W NATOMA ESTATE DR	91364	3	165A111    11	2174010031	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.14813	-118.58067	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.Plan check for a PV1 roof-mounted PV system. System size is 13.8 kWac and consists of (3) inverters, (73) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34168	17041-10000-45701	10200 N RESEDA BLVD	91324	12	204B125   175	2731018018	(Q)C2-1VL, C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.25613	-118.53584	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34169	16041-20000-45157	13730 W VENTURA BLVD	91423	4	165B157   667	2266020004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.148	-118.43213	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,044 sq. ft. No exterior electrical work is included as part of this scope of work. Scope of work only emcompasses interior work.Note: Building permit has been pulled under 16016-10000-19737. Electrical permit fees partially paid for under 17041-30000-01260.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34170	19041-20000-39946	1438 N GOWER ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM			PC Info Complete	10/31/2019 12:00:00 AM	ADDRESS	34.09714	-118.32212	POWER ONLY PLAN CHECK FOR (2) NEW 1200A SERVICES, (2) 1200A MDPS, AND A 2400V 1200A SUBSTATION WITH A 4160V/2400V XFMR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34171	17041-10001-12268	515 S FIGUEROA ST STE 1400	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	PC for changes to approved set under delta 3.  Changing controlled receptacles to regular receptacles due to code cycle. Building #17016-10000-07550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34172	17041-20000-17711	3601 S WATT WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	05/26/2017 12:00:00 AM	ADDRESS	34.02113	-118.28752	Plan check for energy only. New lighting for lecture hall/classroom 106. 1,792sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34173	19041-20000-23088	1114 N WHITE KNOLL DR	90012	1	138B213   501	5406018048	RD1.5-1	Central	Central City North	Historic Cultural North	YES	1977.00	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	09/18/2020 12:00:00 AM	ADDRESS	34.0706	-118.24702	1200A 240/120V 1ph-3w service.  Plan check for power	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34174	12041-20000-17445	18600 W DEVONSHIRE ST Sale-Office	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.25704	-118.53922	New panels and circuits for the sales office building.  Plan checked for T-24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34175	14041-10000-30602	5261 N LA RODA AVE	90041	14	163-5A225 109	5669022026	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.1431	-118.20513	PV1 standard plan , roof-mounted 5KW system including (1) Solaredge SE5000A inverter, (23) Kyocera KD255GX modules and P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34176	11041-20000-24753	12100 W OLYMPIC BLVD	90064	11	123B149   575	4259025010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	ADDRESS	34.03215	-118.45396	T.I.  Remodel of light fixtures and addition of one new panel and branch circuits.  Total new added load is less than 400 amps.  Work to be taking place is for the 2nd floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34177	14041-10000-34725	8556 S EMERSON AVE UNIT 10	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	02/10/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 10 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34178	12041-10000-21331	1750 N HILLHURST AVE	90027	4	147B197    42	5590023004	[Q]C4-2D	Central	Hollywood	Greater Griffith Park		1891.01	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM			PC Approved	09/10/2012 12:00:00 AM	ADDRESS	34.10291	-118.28726	TI in an existing restaurant. EPC is for T24. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34179	13041-10000-04735	970 W 190TH ST 3RD FLOOR	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Approved	02/25/2013 12:00:00 AM	ADDRESS	33.85812	-118.29302	PLAN CHECK ONLY FOR T24 AND EMERGENCY LIGHTING. OFFICE TENANT IMPROVEMENT. SCOPE OF WORK IN SUITE 310 AND 304.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34180	17041-20000-11827	9338 N VALJEAN AVE	91343	12	198B137   392	2676013028	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.24042	-118.4871	pv1install roof mounted pv system sized 6.6kw interconnected wth msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34181	12041-10000-13130	929 S BROADWAY	90015	14	127-5A209 256	5139003005	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.04174	-118.25687	Change of use from an office to a hotel, 13-story building.  1000A service.  Full plan check.  Variance will be filed to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34182	10041-20000-17665	609 S ST PAUL AVE 1-350	90017	1	130-5A207  24	5143025030	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.05337	-118.26134	Plan check for new installation of fire alarm system in a 350 units apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34183	18041-10000-15276	534 N BARNABY ROAD	90077	5	141B149   251	4362006002	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.07896	-118.45398	Plan check for house addition remodel with new 120/208, 3ph, 1200A Service feeding a 1200A distribution board and re-feed existing 800 A distribution borad.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34184	18041-10000-03182	2010 E WASHINGTON BLVD	90021	14	118-5A215  44	5167005805	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM			PC Info Complete	03/16/2018 12:00:00 AM	PIN	34.01855522	-118.23487686	PC FOR POWER FOR A NEW 400AMP SERVICE AT A LOADING DOCK IN A METHANE ZONE. SCOPE INCLUDES NEW LIGHTING, PANELS AND TRANSFORMERS. B# 18019-10000-00338	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34185	18041-10000-00134	4584 S CENTINELA AVE	90066	11	108B157   926	4232026052	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Issued	01/03/2018 12:00:00 AM	ADDRESS	33.99147	-118.42119	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34186	18041-30000-03558	1522 S ORANGE GROVE AVE	90019	10	129B177   953	5068026020	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.04874	-118.36605	Full PC for power and energy. Plan check for a 17 unit apartment building. Scope includes a new 1000A 120/240V 3 Phase 4 Wire Service/Distribution board, new panels, and new circuits. Total affected area is 19045 SQ. FT. B#16010-30000-06367	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34187	19041-10000-34153	380 WORLD WAY SPACE T56	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Approved	08/29/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for a food concession T.I  (Playa vista) located in the kitchen area. Scope includes new lighting and equipment with a total lighting area of 200-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34188	16041-20000-19690	13107 W AZTEC ST	91342	7	228B161   592	2511018008	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.32004	-118.41862	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.5KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34189	19041-20000-12740	5670 W WILSHIRE BLVD STE 1950	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	T24 PLAN CHECK FOR TI REMODEL OF SUITE ON 19TH FLOOR OF EXISTING COMMERCIAL HIGH RISE. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 2,495 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34190	17041-10001-38632	2111 N GRIFFIN AVE	90031	1	136-5A223  28	5204018006	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.06975	-118.21183	"DELTA ""A"" CHANGES TO APPROVED PLANS. RE-DESIGN OF 1-LINE DWG, SWITCHING TO 3 PHASE FROM 1 PHASE.  REFEEDING 9 EXISTING PANELS. <<<<FULL PC FOR A NEW GYMNASIUM TO AN EXISTING HIGH SCHOOL, WITH FULL KITCHEN AND STAGE PLATFORM. OCC. LOAD > 100. NEW 1600 AMP SERVICE FOR THE SCHOOL, PANELS FEEDING THE CLASSROOMS WILL BE EXISTING.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34191	18041-10000-40400	5299 W 111TH ST	90045	11	087B173    10	4129036910	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	33.93528	-118.37235	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34192	11041-20000-17856	9830 N LASAINE AVE	91325	12	201B129   122	2755013035	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2011 12:00:00 AM	10/20/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.24956	-118.51265	New 8.385KW roof mounted Photovoltaic System single family dwelling includes upgrading service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34193	19041-10000-50357	9956 W TOLUCA LAKE AVE	91602	4	165B181   479	2424030018	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM			PC Approved	12/01/2023 12:00:00 AM	ADDRESS	34.14702	-118.34831	Plan Check ONLY, Remodel of an existing 2 STORY SFD,  NEW 800A SERVICE (1P,3W), THAT FEEDS EIGHT HOUSE PANELS AND ONE ELEVATOR. PER BUILDING PERMIT: 18014-10000-02413, REMODEL AND ADDITION TO (E) 2-STORY SFD). ELECTRICAL PERMIT WAS ISSUED UNDER BUILDING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34194	16041-10000-13420	5800 W SUNSET BLVD TEMP	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	05/04/2016 12:00:00 AM	ADDRESS	34.09728	-118.31693	VOID - WRONG DATA TYPECONDUIT ONLY FOR TEMP SERVICE. MODIFICATION FILED - 16041-10000-13416	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34195	11041-10000-27200	3100 W BERKELEY CIR	90026	13	144A205   402	5425005032	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2011 12:00:00 AM			Ready to Issue	01/20/2012 12:00:00 AM	ADDRESS	34.08787	-118.27271	PLAN CHECK INSTALLATION ENPHASE MICROINVERTER M215 9.8 KW PV SYSTEM. ROOF MOUNTED ON SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34196	11041-20000-15522	11009 W BURBANK BLVD #126	91601	2	174B173   864	2337025017	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM			PC Approved	07/25/2011 12:00:00 AM	ADDRESS	34.17232	-118.37072	PLAN CHECK T24 ENERGY & EMERGENCY FOR TAKE OUT RESTAURANT (FAT BURGER) SUITE #126	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34197	19041-10000-16517	5731 S MCKINLEY AVE	90011	9	108B205  1048	5103014007	MR1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.20	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	33.98998	-118.26094	ENERGY PLAN ONLY FOR TI (OFFICES), AREA 547 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34198	13041-20000-06498	15616 W CASTLEWOODS DR PV-1	91403	5	159B141   243	2280014016	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Expired	08/19/2015 12:00:00 AM	ADDRESS	34.13323	-118.47394	PV-1. Plan check for single family dwelling. Micro-inverters. 7.31kW total AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34199	12041-10000-16211	1717 E BENTON WAY	90026	13	144A207   166	5423027019	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	08/22/2012 12:00:00 AM	ADDRESS	34.08862	-118.26554	New rooftop 7.92kw photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34200	14041-10000-06730	123 S HOBART BLVD	90004	10	138B193  1043	5517012030	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Expired	04/21/2016 12:00:00 AM	ADDRESS	34.07303	-118.30563	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(15) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34201	14041-20000-05303	12963 W KELOWNA ST	91331	7	204B161   514	2623018020	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Expired	03/22/2016 12:00:00 AM	ADDRESS	34.25407	-118.41516	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34202	12041-10001-11453	12181 W BLUFF CREEK DR Suite 101-5th Floor	90094	11	102B161  1150	4211010061	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Info Complete	07/09/2012 12:00:00 AM	ADDRESS	33.97788	-118.40638	Plan check for power only. First time tenant on 5th floor (California Pizza Kitchen Corp  Office). Change to lighting, new transformer, panels, circuits, and equipment. T24 Energy/emergency lighting approved on previous application #12041-10001-11453	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34203	13041-20000-13735	309 S BUNDY DR PV1	90049	11	132B141   521	4404011011	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM			PC Approved	06/14/2013 12:00:00 AM	ADDRESS	34.05753	-118.47648	PV1 FOR TRANSFORMERLESS SYSTEM. EXPRESS PERMIT HAS ALREADY BEEN PULLED (13041-20000-11794), THIS IS A PLAN CHECK ONLY. TOTAL SYSTEM SIZE 3.3 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34204	15041-10000-43927	8715 S RAMSGATE AVE	90045	11	096B169   727	4125013020	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Issued	12/30/2015 12:00:00 AM	ADDRESS	33.95853	-118.38281	Installing new fire alarm panel on existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34205	19041-10000-32408	11566 W KELSEY ST	91604	2	162B169   345	2368007020	RE11-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.14179	-118.38468	PV1, new rooftop mounted system, system size is 15.2 KWdc/ 10KWac. Scope of work is 50 modules (Seraphim SEG -305-6MB-BB) with optimzers (SE P320) , and a central inverter (SE 10000H-US). No panel upgrade	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34206	14041-10000-34665	444 S FLOWER ST 2ND FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	Renovation of (E) commercial space to furniture showroom.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34207	10041-20000-12105	11154-11170 W AQUA VISTA ST BLDG  A	91602	2	162B173   143	2366027011	OS-1XL, R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.01	Electrical	Electrical	Apartment			06/24/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.14476	-118.37362	NEW 3 STORY 60 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34208	15041-20001-22607	2409 N NOTTINGHAM AVE	90027	4	153B193   376	5588003013	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.11234	-118.30184	Expedited per customer request.PV1. Install roof mounted PV system sized 6.5 kW. Interconnected with main service panel. (26) SW285 Modules(26) Enphase M250 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34209	19041-20000-34177	20600 W BLUEBIRD CT	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.29693	-118.58234	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34210	19041-10000-05798	11766 W WILSHIRE BLVD 310	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.04804	-118.46227	TI 24 PC ONLY FOR NEW LIGHTING AND RECEPTACLES FOR A SPEC SUITE IN EXISTING HIGH RISE COMMERCIAL BUILDING. TOTAL SQUARE FOOTAGE = 1,955 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34211	17041-10000-19320	1410 E 110TH ST	90059	15	088-5A211 349	6070007015	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	ADDRESS	33.93569	-118.24987	PC for rooftop 3.8KW  solar.PC for 10 AXITEC AC -265P modules with one Fronius Primo 3.8 central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34212	18041-20000-00964	615 W CHILDS WAY Suite 101	90089	9	118-5A201  27	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.0191	-118.28214	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 372 sq. ft.Note: Building application has been generated under 17016-10000-32992	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34213	15041-10001-42273	820 E 119TH ST	90059	15	084B209   687	6084019008	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	33.92451	-118.26011	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE REDUCTION OF 3 MODULES, FROM 27 TO 24 MODLUES. PC ONLY. (((PV1 SFD TOTAL SYSTEM SIZE 7.6KW AC USING STANDARD PLAN. TOTAL OF 27 MODULES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34214	14041-20001-25457	21301 W BURBANK BLVD 4TH FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.17351	-118.59524	[[[[11/12/14  CHANGES TO APPROVED SET OF PLANS. CHANGES HAVE BEEN CLOUDED. NO DELTA DESIGNATION PROVIDED.]]]]]TI FOR FULL 4TH FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34215	11041-10000-06331	2049 S CENTURY PARK EAST 32ND FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	04/15/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	T.I.  TITLE 24 PLAN CHECK ONLY.  32ND FLOOR OF HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34216	15041-10000-04941	1019 S CATALINA ST	90006	10	129B197   235	5078013028	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			03/06/2015 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.05214	-118.29493	Plan check for power and energy for new mixed-use apartment building with 4 stories apartment dwelling units. 69 unit apartment with 2500A-rated 208Y/120 service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34217	19041-20000-18622	11601 W WILSHIRE BLVD STE 1820	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	T24 ONLY PLAN CHECK, TI REMODEL OF LIGHTS AND OUTLETS ONLY IN EXISTING HIGH RISE COMMERCIAL. TOTAL SQUARE FOOTAGE = 1,442SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34218	14041-20000-26400	9800 N VENA AVE	91331	6	201B157   301	2621001007	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			Corrections Issued	10/29/2014 12:00:00 AM	ADDRESS	34.24844	-118.42824	PV1.  Install 5.886 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34219	13041-10000-30815	7752 N FARRALONE AVE	91304	3	189B101   709	2012030020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.21148	-118.61016	PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with service center-fed panel. Transformerless inverter: Solaredge SE 3000A-US. 10 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34220	18041-10000-07823	1485 W SUNSET BLVD # J	90026	13	139-5A209 265	5406001017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	04/29/2021 12:00:00 AM	ADDRESS	34.07579	-118.25461	REMOVE 2ND FLOOR AND CHANGE OF USE TO A RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34221	14041-20000-02492	7640 N TAMPA AVE	91335	3	186B117    83	2104012066	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Expired	06/06/2016 12:00:00 AM	ADDRESS	34.20967	-118.55333	NEW 1200 AMPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34222	15041-20000-19280	7611 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.20894	-118.46494	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34223	16041-10001-20178	809 S HILL ST 807,809,-813,815	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.04431	-118.2562	PC ONLY!SCOPE INCLUDES REVISION TO APPROVED SET PER INSPECTION. ADDING A FUSE TO RESOLVE AIC RATING ON MSB.  CORE AND SHELL UPGRADE OF EXISTING BUILDING.  INSTALLING NEW 1600A SERVICE MS-B  AND HOUSE PANEL WITH 3 CONDUIT STUBS FOR FUTURE TENANTS.Building located on Methane (Buffer) zone per Zimas.B#15016-10000-26929	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34224	11041-20000-16324	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM			PC Info Complete	08/03/2011 12:00:00 AM	ADDRESS	34.05979	-118.41671	energy plan check # 6,7,8, 10 floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34225	15041-10004-03435	200 WORLD WAY #233	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	CHANGES TO DELTA 6. CHANGE FROM FIXTURE FROM AN F10 TO F13 TO AN OPPOSITE WALL. PC FOR TITLE 24 ONLY.  TOTAL AREA = 550 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34226	11041-20000-04392	1015 W FIGUEROA TER BLDG 1	90012	1	136-5A213  45	5406022078	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			03/07/2011 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.0687	-118.24529	PLAN CHECK POWER AND ENERGY FOR NEW 22 UNIT APARTMENT BUILDING.  IN METHANE ZONE.  A varinace to separate out the fire alarm appproval was submitted on December 27, 2011.  The methane component of the project was reviewed, and the plan shows substantial compliance with the methane requirements.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34227	19041-20000-01134	3566 W BEVERLY BLVD STE 204	90004	13	138A201    65	5501007029	M1-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.07391	-118.28653	FULL PC FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES NEW POWER AND LIGHTING LAYOUT FOR NEW MEDICAL OFFICE IN EXISTING BUILDING, TOTAL SQUARE FOOTAGE = 1644	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34228	14041-20000-14536	11909 N COMETA AVE	91331	7	216B161   477	2527008017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.28633	-118.41261	pv1 single family dwelling. total system size 3.6 kw ac using microinverters enphase m215. nonstnadard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34229	15041-20000-11885	2880 N BENEDICT CANYON DR	90210	5	156B153   183	4382007013	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.12294	-118.43412	Plan check for ground-mounted photovoltaic system. System size: 22kWac with 56 modules(Sun power spr-x21-345) and (2) SMA 11kW ungrounded inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34230	19041-20000-42043	3662 S MCLAUGHLIN AVE	90066	11	114B157   335	4234013013	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.01097	-118.42624	Plan check for PV roof mounted system and energy storage system, PV system size: 4.93KW DC, 3.8KW AC with 17 PV Modules, 1 inverter(3.8KW) and 1 LG Chem battery back up, new sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34231	13041-10001-06290	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM			PC Approved	09/30/2014 12:00:00 AM	ADDRESS	33.96577	-118.42406	Plan check for power only. Changes to approved plans under delta 3 and 4 (not marked on plans but highlighted - to be clouded by engineer before approval).  Sheets 6.01/2/3/4/5 and E5.10 modified. Feeders for 100A ampacity and higher to be changed to aluminum instead of copper. A lockable non-fused disconnect added to normal side for fire pump per project inspector (location of disconnect on sheet E5.10 in electrical medium power station.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34232	17041-20000-10836	4452 W MELBOURNE AVE	90027	4	150B201  1441	5590023002	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.10343	-118.28699	Plan check for energy only. TI to retail building. New lighting. 378sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34233	18041-10000-48219	12321 W ROCHEDALE LANE	90049	11	138B141   354	4494008009	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	01/16/2019 12:00:00 AM		Issued	01/16/2019 12:00:00 AM	ADDRESS	34.07343	-118.48385	$0 Permit Fee due to AB 1414PLAN CHECK FOR ROOF MOUNTED 7.46KWA SYSTEM CONNECTED WITH AN EXISTNG 4.0KVA SYSTEM TO AN EXISTING 400A 120/240 PANEL. SYSTEM CONSIST OF 1 CENTRAL INVERTER(SE7600H-US) WITH 27 MODULES USING P320 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34234	18041-20001-06104	3420 S VIRGINIA ROAD	90016	10	120B185   949	5046004007	RD3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM			PC Approved	07/05/2018 12:00:00 AM	ADDRESS	34.02485	-118.33933	7/5/2018relocate existing battery equipment.  this is plan check only.(((plan check for battery back up system with an existing solar system - battery size = 14kwh with backup gateway.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34235	17041-10000-14954	7725 N RESEDA BLVD	91335	3	189B125   833	2103025901	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Apartment			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.21096	-118.53626	PC for energy only, Removing HID fixtures and replacing them with new LED. Area: 16,050 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34236	19041-10000-48859	14637 W AETNA ST	91411	6	177A151    87	2241026003	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.18023	-118.45224	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34237	19041-20000-05410	8248 N WEBB AVE	91605	6	192B169   497	2310005013	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.22069	-118.39193	Plan check for PV roof mounted system, system size: 7.5KW DC, 6.53KW AC with 25 PV Modules and 1 inverter(6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34238	18041-20000-31693	8837 N BURNET AVE 1-12	91343	6	195B145   333	2654008024	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Apartment			08/21/2018 12:00:00 AM	10/07/2019 12:00:00 AM		Issued	10/07/2019 12:00:00 AM	ADDRESS	34.23113	-118.46351	Plan check for power and energy for new apartment building 3 story 12 units with parking garage 800A. Total area: 10173 sq ft. B#15010-10000-01885Fire alarm Variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34239	17041-10000-46374	2600 S CATALINA ST	90007	8	123B197   906	5054028018	[Q]C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Apartment			12/27/2017 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	07/01/2022 12:00:00 AM	ADDRESS	34.03245	-118.29412	PC FOR POWER AND ENERGY A NEW SERVICE 1200A 120/208 3PH IN A METHANE BUFFER ZONE. TOTAL AFFECTED AREA OF 11520 SQ.FTELECTRIC CAR CHARGER NOT PROVIDED AT SUBMITTAL.B#17010-10000-05120	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34240	14041-10003-14918	2239 W QUEENSBOROUGH LANE	90049	5	150B141    86	4377046004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	08/09/2014 12:00:00 AM	ADDRESS	34.10938	-118.47778	(((8/6/2014 Expedite fees for previous supl. app. for addition of 3 solar PV modules)))(((8/6/2014 Zero fee because of senate bill 2221.  Supl. app. for addition of 3 solar PV modules to previously approved existing system.  Total inverter output power = 6.8 kWac)))PV1, INSTALL 7.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34241	10041-10000-03828	2081 N HILLHURST AVE	90027	4	150B197   206	5590007036	C4-1D	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM			PC Info Complete	03/17/2010 12:00:00 AM	ADDRESS	34.10968	-118.28759	Plan check T-24 Energy general/emergency lighting for remodel of existing Coffee Bean & Tea Leaf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34242	17041-20000-01891	18523 W OLDENBURG LANE	91344	12	219B125   140	2601075025	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.29414	-118.53581	Plan check for installation of solar pv system, roof-mounted on SFD.15.2kW ungrounded system (2*7.6kW). (54) 315W pv modules.$0 permit fee per SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34243	17041-20000-04243	850 W BLOOM WALK	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Info Complete	02/09/2017 12:00:00 AM	ADDRESS	34.0194	-118.28808	replace existing outdoor light fixtures to new led fixures.  plan check for energy only.total square footage 4876	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34244	13041-10000-24735	2508 1/2 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.0334	-118.2974	PV2.  Instal 2.94 kW DC roof-mounted solar array of 12 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34245	18041-10000-46793	15057 W BURBANK BLVD	91411	4	174B145   444	2243009021	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.17231	-118.4615	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34246	15041-20000-19193	1127 S RIDGELEY DR	90019	4	132B177  1138	5085007034	R1-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.05505	-118.35349	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34247	11041-20000-20228	1400 S WESTWOOD BLVD	90024	5	132B153   846	4325019017	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.05515	-118.44139	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34248	14041-10000-03331	9003 N WHITAKER AVE	91343	12	195B133    80	2688025037	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.23417	-118.49919	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 10KW DC.(40) SOLAR WORLD SW 250(40) ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34249	17041-20000-26122	1251 S EDRIS DR	90035	5	132A167   372	4330024041	RD1.5-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			08/01/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.05575	-118.39818	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.65 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34250	14041-10000-34347	8520 N REMICK AVE	91352	6	192B165   176	2634022013	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.22545	-118.39956	PV1, INSTALL 4.08 KW DC SOLAR RRAY ON A SINGLE DWELLING HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: REC SOLAR REC256PE BLK (1) INVERTER: POWERONE PVI-3.6-OUTD-S-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34251	14041-10002-24763	380 WORLD WAY T 03	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to an approved set of plans (Delta 4 only). The track lighting current limiter has been changed (current limiter now has an increased amperage). There are also additional loads on Panel L3A.(((Modification to approved set, delta 2 and 3 revisions only.  Revised fixture schedule and Title 24 forms.  Additonal revisions not related to scope of Title 24 plan check - revised load schedule and panel schedule.  Affected sheets: T-24-1, E-2.0, E-2.1)))(((Title 24 plan check only.  Total area = 773 sq. ft.TI to airport terminal kiosk.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34252	15041-10000-21069	350 S FIGUEROA ST SUITE #750	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.05438	-118.2549	PLAN CHECK FOR ENERGY ONLY FOR EXISTING OFFICE IN HIGHRISE BUILDING. SCOPE OF WORK IS ON THE 7TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34253	10041-10000-23003	1214 E 18TH ST	90021	9	121-5A211 382	5131003002	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	06/06/2011 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	34.02538	-118.25035	TENANT IMPROVEMENT OF ADMINISTRATIVE OFFICES  ON SECOND FLOOR W/ NEW LOBBY AREA AND EMPLOYEE ENTRANCE ON GROUND FLOOR NEW STAIR OPENING & ELEVATOR & SOME STRUCTURAL WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34254	16041-20000-38704	13359 N MISSION TIERRA WAY	91344	12	225B133    97	2601013040	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.31264	-118.50167	Plan check for installation of solar pv system, roof-mounted on SFD. 12kW (6+6) ungrounded system. (50) 320W pv modules. Each module has a 400W power optimizer.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34255	14041-10001-08895	7080 W HOLLYWOOD BLVD # 102	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM			Corrections Issued	04/25/2014 12:00:00 AM	ADDRESS	34.10134	-118.34445	CHANGES TO APPROVED: EMG LTG IS NL.TI FOR CHANGE OF USE FROM OFFICE TO CLASSROOM. TOTAL NEW LOAD DOES NOT EXCEED 400AMPS. PLAN CHECK FOR ENERGY ONLY. BUILDING APPLICATION#: 14016-10000-04989	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34256	14041-10000-23953	16600 W ADLON ROAD	91436	5	165B137   518	2291013046	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.14506	-118.49537	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.INSTALL 16.83 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(66) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGED SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34257	15041-20001-42250	3764 S DUBLIN AVE	90008	10	117B189   546	5034013049	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	PIN	34.01823208	-118.32207663	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.12KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34258	16041-20000-07449	248 S MAIN ST	90291	11	111B141   614	4286003020	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	33.99669	-118.47804	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,055 sq. ft.Note: Building permit has been pulled 15016-10000-28288	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34259	18041-10000-08990	1875 CENTURY PARK EAST 18TH FLR.	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	PIN	34.06084104	-118.41471001	TENANT IMPROVEMENT OF 17,912 SF. OFFICE SPACE. WORK TO INCLUDE NEW NON-STRUCTURAL PARTITIONS, FIXTURES, AND FINISHES.  NO CHANGE IN USE OR PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34260	15041-30000-39705	15156 W COBALT ST	91342	7	225B145   203	2501022017	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.3137	-118.46222	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 9.6 kWac.  Two inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34261	14041-10009-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			07/01/2019 12:00:00 AM			PC Info Complete	07/16/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	Delta 18 changes to an approved set. Changes to electrical panel schedule due to the addition of receptacle and pedestals for outdoor farmers market. Changes also include an addition of mechanical equipment for ventelation and relocation of electrical room. No changes to lighting or T-24.  A brief narrative is provided. All changes are clouded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34262	14041-10000-10186	4346 W KINGSWELL AVE	90027	4	148-5A201  31	5591026003	R2-1XL	Central	Hollywood	Los Feliz		1952.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.1026	-118.28467	Install 4 kW DC roof-mounted solar array on a single-story house, interconnect with  main service panel. (1)Transformerless inverter: SOLAREDGE SE 3800A-US-ZB-U. (16) Modules: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34263	14041-20000-26172	8246 N JUMILLA AVE	91306	3	192B117   877	2106021018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.21926	-118.56324	PV1Install roof-mounted solar array on SFD. System size: 6kW.(2) SMA Sunny Boy 3000TL-US-22 transformerless inverters(25) Trina Solar TSM250PA05.05 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34264	17041-20000-38501	20951 W BURTON ST	91304	3	192B109   822	2109004013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.2189	-118.59038	Plan check for a PV1 roof-mounted PV system. System size is 14.5 kWac and consists of (42) AC PV modules and (1) load center.$7.47 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34265	14041-20000-14833	4705 N LAUREL CANYON BLVD 4th floor	91607	2	168B165   697	2356037030	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.15593	-118.39668	Commercial office TI in a lowrise commercial building.   Plan check for Title 24 Part 6 compliance for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34266	11041-20000-20243	22020 W CALVERT ST	91367	3	177B101   110	2146025002	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	11/18/2011 12:00:00 AM	ADDRESS	34.18094	-118.60662	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34267	19041-10000-00129	6600 N TOPANGA CANYON BLVD 1100	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Energy plan check for a convenience store located inside Westfield Mall. Scope includes new lighting and equipment with a total area of 1,919-SQ FT.Bld: 19016-10000-00085	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34268	11041-20000-09250	19350 W NORDHOFF WAY	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.23523	-118.55518	T.I. to existing building.  Install general lighting in bakery area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34269	19041-10000-11868	1040 N LAS PALMAS AVE STAGE 11	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION OF A NEW FACP WITH 5 DEVICES IN STAGE 11	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34270	12041-20000-03142	21142 W VENTURA BLVD	91364	3	171B105   194	2167002011	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM			PC Approved	03/12/2012 12:00:00 AM	ADDRESS	34.16702	-118.59423	Upgrade main service to 1200 amperes and have additional meters.Electrical Permit 12041-20000-05808	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34271	17041-20002-20414	19536 W WELLS DR	91356	3	171B117   397	2175011010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			PC Approved	07/13/2017 12:00:00 AM	ADDRESS	34.1635	-118.55916	[[[7/13/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING THE SYSTEM TO (1) SOLAR EDGE 11400A INVETER]]]]pv1install roof mounted pv system sized 12kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34272	13041-10000-18838	523 W 6TH ST suite 606	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			Corrections Issued	07/18/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	OFFICE TI, TENANT LIGHTING SYSTEM, ADDITION OF RECEPTACLES IN HIGH-RISE BUILDING. TITLE 24 PLAN CHECK ONLY, PERMIT TO BE ISSUED AT THE ELECTRICAL PLAN CHECK COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34273	19041-20000-44896	11529 N SPROULE AVE	91331	7	213B161   676	2532006012	A2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Closed	02/25/2020 12:00:00 AM	ADDRESS	34.27924	-118.40771	PV1 PLAN CHECK FOR NEW 15.12 KW DC/15.2 KW AC PV SYSTEM. SCOPE OF WORK CONSISTS OF (48) PV MODULES WITH OPTIMIZERS AND (2) 7.6 KW INVERTERS AND A NEW LOAD CENTERFEES $ 0.00 DUE TO CALIFORNIA SENATE BILL 1222 AND AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34274	14041-10000-13136	1545 S WESTERN AVE	90019	10	126B193   252	5073011028	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	PIN	34.04401325	-118.30937336	Ti for an elpollo loco fast food. tile 24 and emergency lighting. one story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34275	10041-20000-12356	5670 W WILSHIRE BLVD 22nd Floor	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	07/22/2010 12:00:00 AM		Permit Finaled	10/06/2010 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check T-24 Energy (general/emergency) lighting on the 22nd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34276	12041-20000-11010	660 W 28TH ST	90007	8	121-5A203 131	5123013410	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			05/14/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Issued	06/27/2012 12:00:00 AM	ADDRESS	34.0268	-118.27924	TI to apartment. Currently a fraternity house. Plan check for power. Energy is under residential.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34277	19041-10000-32346	2417 W BEVERLY BLVD	90057	13	136-5A203 141	5157010004	C2-1	Central	Westlake	Echo Park	YES	2085.01	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	02/27/2020 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.06864	-118.27441	FULL PC FOR INTERIOR TENANT IMPROVEMENT OF OFFICE SPACE ON BOTH FLOORS OF TWO STORY BUILDING. IMPROVEMENTS INCLUDE OFFICE SPACE, FURNITURE, FINISHES, STAIRS AND PARKING LOT MODIFICATION, STRIPE AND RESTRIPE. NEW LOAD IS OVER 400A. AREA OF SCOPE 9587SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34278	14041-10000-06725	1407 S CABRILLO AVE	90291	11	108B145  1424	4238004018	RD1.5-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	33.99025	-118.46688	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  2-STORY HOME. INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(14) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34279	18041-20000-45644	16838 W ADDISON ST	91436	5	171B133   670	2259005012	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.16172	-118.50006	Plan check for a PV1 roof-mounted PV system. System size is 18.1 kWdc/15.4 kWac-CEC and consists of (55) micro-inverters, (55) modules, and (1) load center.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34280	14041-10000-12557	503 N KINGSLEY DR	90004	13	141B193  1239	5521010026	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.0801	-118.30363	PV system for residential - system size = 3.57 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34281	16041-20001-24557	2251 W HILL DR	90041	14	163-5A221  85	5671002004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.14301	-118.21503	EXPEDITE PER APLLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM TO TIE WITH EXISTING PV SYSTEM AND MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34282	15041-20002-11745	6250 N TOPANGA CANYON BLVD F-1505	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	7/29/15. CHANGES TO APPROVED SET. DELTA 5 CHANGES ONLY.   ADDITION OF SHOW WINDOW RECEPTACLES AND CIRCUIT. CHANGING OF SOME FEEDERS TO COPPER FROM ALUMINUM.07-22-2015 Change to approved set of plans, changes include change from 1 transformer to 2 transformers and 1 addition panel, changes apply to delta 5 only [[[[[T. I to new commercial building (restaurant and bar). Plan check for power and energy. Total sqft. 3200]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34283	16041-20007-12885	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Closed	10/15/2020 12:00:00 AM	ADDRESS	34.21922	-118.44896	"4/4/2019changes to an approved set of plans.  changes noted delta 2A to add new equipment and relocate existing equipment.  plan check for power.((((Supplemental application for changes to layout of single line including fire pump connection in existing 13 story commercial highrise adaptive resuse project.  Downsize service ""MS1"" and emergency generator.  Increase size of service ""MS2"".  Relocate loads from ""MS1A"" to ""MS2"".  Add new loads to service ""MS1"" including EV chargers.   Changes to retail areas.  Master application has not been approved - SH original plan checker.))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34284	15041-10000-23206	19851 W NORDHOFF PL	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Closed	09/29/2015 12:00:00 AM	ADDRESS	34.23624	-118.56649	TI 24 REMOVE HID LIGH FIXTURES AND REPLACE WITH NEW LED FIXTURESTOTAL AREA = 4926 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34285	12041-20000-20373	1828 E CESAR E CHAVEZ AVE	90033	14	130-5A221 325	5174008022	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.05014	-118.21571	New fire alarm system for core & shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34286	14041-10000-01484	1404 N LUCILE AVE	90026	13	144A203   154	5427015012	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.08949	-118.27954	PV1, INSTALL 14.49 KW DC ROOF-MOUNTED SOLAR ARRAY FOR A  TWO STORY HOUSE. INTERCONNECT WITH MAIN SERVICE PANEL.(7 )STRINGS(2) INVERTERS: SUN POWER SPR-6000M AND  SUNPOWER SPR-7501F-1 UNI (42) MODULES: SUNPOWER SPR-X21-345***Since the application was copied from the one of the original ones, contractor information was been copied and then removed.***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34287	19041-30000-38448	11601 W WILSHIRE BLVD STE 1100	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	T-24 PLAN CHECK ONLY, Interior tenant improvement to combine (E) office suites to create Suite 1100.  Scope of work to includeS new lighting and recetacles. Total sq. ft. 6693	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34288	13041-10000-27652	5651 W MANCHESTER AVE	90045	11	096B169   254	4125001901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.96006	-118.37965	New fire alarm system. 2 panels and 701 devices. fully sprinked and not a high rise according to applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34289	14041-20001-14411	18564 S WESTERN AVE	90248	15	060B193   210	6108001055	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Approved	03/29/2017 12:00:00 AM	ADDRESS	33.86223	-118.30895	Revisions to approved plans.  Additional sump pump controller, ADA lift, and changes to lighting system.  Delta revisions 3 thru 6 only.  (((Addition to existing car dealership.  Connection of 2 existing buildings and new service/distribution equipment.  Power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34290	14041-20000-17728	6767 N IRONDALE AVE	91306	3	180B109    16	2148005002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM			Corrections Issued	07/01/2014 12:00:00 AM	ADDRESS	34.19356	-118.58503	PV1.  Install 4.59 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34291	12041-10000-19375	5516 N FIGUEROA ST	90042	1	151-5A227 314	5468026013	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	34.10809	-118.19548	T.I. to an existing Retail Space.  New 600 Amp Service, sub panels and circuits.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34292	15041-20000-41485	14592 W PADDOCK ST	91342	7	222B149   754	2505014010	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.3037	-118.45058	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.8KW. (26)MODULES-TRINA SOLAR TSM-PD05.08-265W(26)MICROINVERTERS-ENPHASE M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34293	19041-10000-17665	8730 W FOOTHILL BLVD	91040	7	207B189  1064	2547027002	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1032.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM			Corrections Issued	05/10/2019 12:00:00 AM	ADDRESS	34.26024	-118.32388	PLAN CHECK FOR T24 ONLY, CONVERSION OF RETAIL SALES SPACE TO RESTAURANT DICKIE'S BARBECUE PIT. INSTALL NEW 125A PANEL FED FROM (E) DIST. BOARD. AREA APPROX. 1,973 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34294	19041-10000-36717	2171 N CEDARHURST DR	90027	4	150B201   106	5591006004	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.11101	-118.28338	Plan check for a Standard Plan PV1 5kw AC /6.2KW DC roof mounted system. Scope includes (1) inverter, (17) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34295	12041-10000-04470	3641 S WATT WAY #309	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM			PC Approved	02/28/2012 12:00:00 AM	ADDRESS	34.02033	-118.28801	T.I. to an existing Labratory at USC in the HEDCO Neuroscience Building on the 3rd Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34296	12041-20000-19959	6882 S ARIZONA AVE	90045	11	102B165   127	4110001028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2012 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.97776	-118.39577	single family. new electrical work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34297	16041-20000-08630	700 S FLOWER ST 22ND FLOOR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 22ND FLOOR RESTROOMS AND LOBBY. HIGHR RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34298	12041-10000-25580	7200 W FOOTHILL BLVD #102	91042	7	202-5A199 484	2563016018	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu, Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM			Reviewed by Supervisor	11/05/2012 12:00:00 AM	ADDRESS	34.24842	-118.28878	First time tenant, commercial Full Plan check, T24 and emergency lights. 967 sq ft.Permit was obtained on 12041-10000-25675	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34299	19041-10000-13415	1218 S MAIN ST	90015	14	124-5A209  49	5139027016	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.03691	-118.25963	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34300	18041-10001-42270	11100 W SANTA MONICA BLVD 525	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY REDUCTION IN LIGHTING FIXTURES. <<<TI FOR AN INTERIOR OFFICE SPACE, SUITE 525. SCOPE INCLUDES NEW LIGHTS AND RECEPTICALS. TOTAL AFFECTED AREA IS  1261 SQ. FT. T-24 ONLYB#: 18016-10000-35217>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34301	16041-20000-01073	6534 N MURIETTA AVE	91401	2	180B153   695	2238020016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.18954	-118.43876	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34302	13041-10000-26701	8500 W BEVERLY BLVD UNIT 695	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	TITLE 24 PLAN CHECK ONLY. TENANT IMPROVEMENT FOR AN EXISTING RETAIL SPACE IN BEVERLY CENTER MALL. 1154 SQFT. EMERGECNY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. additional fee has been charged under submittal 2 for multiple verifications.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34303	15041-20000-01264	215 W 7TH ST	90014	14	127-5A211 340	5144026***	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.04496	-118.25266	TI to an existing commercial building. Adding new lights and controls to existing pannels. Plan check for energy and emergency lighting only. Total sqft 1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34304	18041-10001-04389	5137 N FIGUEROA ST	90042	1	150A227   112	5468003020	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.10635	-118.19984	Full PC.Installation of new 800A service, panel, and lighting for an automated self service car wash. Permit is pulled under master 18041-10000-04389.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34305	17041-10000-09304	2001 S WESTERN AVE	90018	10	126B193  1083	5073030065	[Q]C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.03857	-118.30924	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 5600 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34306	17041-10000-00820	11205 S LA CIENEGA BLVD	90045	11	087B173    85	4129038024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	33.93322	-118.37022	Plan check for Title 24 only in walk-in cooler. Total area: 2,935  sq ft. Building Permit #:16041-20001-09881	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34307	17041-10000-00480	1540 S ROBERTSON BLVD	90035	5	129B169   550	4303002011	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.05108	-118.38408	FULL PLAN CHECK. CHANGE OF USE FROM  OFFICE/STORAGE TO PRIVATE HIGH SCHOOL, (9th-12th GRADE). OCCUPANCY LOAD IS GREATER THAN 100. INCLUDES PLACE OF ASSEMBLY. ADDING NEW EQUIPMENT ON SINGLE LINE UNDER EXISTING SERVICE. TOTAL AREA: 6,647. BUILDING APP. 16016-10000-09124.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34308	18041-20001-31739	1211 E PRESTON WAY	90291	11	111B149   355	4244026004	R1-1VLD	West Los Angeles	Venice	Grass Roots Venice	YES	2731.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/29/2018 12:00:00 AM	ADDRESS	34.00225	-118.45613	CHANGES TO PERMITED SET, CHANGES INCLUDE UYPGRADING THE PANEL TO 225 AMP. CHANGES APPLY TO DELTA B ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34309	10041-10000-25771	2866 W 7TH ST	90005	1	133-5A201 181	5077015008	C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM			PC Approved	12/20/2011 12:00:00 AM	ADDRESS	34.05967	-118.28596	New and altered lighting in an existing subdivied building.  Check for T24 in both portions of the existing structure.  There are two sets of plans, one identified as Market, and the other as Tenant Improvement, they are used together as one set of plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34310	12041-20000-11820	12148 W HART ST 1-25	91605	2	183B165   274	2321009041	R3-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			05/22/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.19731	-118.39828	New fire alarm for new apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34311	17041-10000-33162	11402 W TUXFORD ST	91352	6	195B173   454	2408024002	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.22866	-118.37906	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 112,200 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34312	15041-10000-35406	3002 1/2 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	ADDRESS	34.02706	-118.42817	PC FOR ENERGY. T.I. FOR EXISTING AT&T RETAIL OFFICE BUILDING . TOTAL AREA 2209 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34313	18041-10000-19790	20039 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	ADDRESS	34.27566	-118.57078	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A NEW RETAIL BUILDING. SCOPE INCLUDES A NEW 800A 277/480V 3 PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS, NEW 112.5KVA TRANSFORMER, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 25003 SQ. FT. . B#18016-10000-16954	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34314	13041-10000-15767	430 S BROADWAY	90013	14	129A211    57	5149024008	[Q]C4-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			06/18/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.04864	-118.24991	"conversion of retrofit building to 58 UNIT MIXED USED BUILDINGATTACHED TO THE PLANS ARE MODIFICATIONS OF BUILDING ORDINANCES FOR THE BUILDING TO KEEP ITS ""NON-HIGH RISE STATUS"" MODIFICATIONS WERE DATED May 9th 2013 and signed by Jameson Lee"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34315	19041-20000-10839	7337 N NITA AVE	91303	3	186B101   754	2023027007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.20394	-118.61376	Plan check for PV roof mounted system, system size: 10.15KW DC, 9.0KW AC with 35 PV Modules and 1 inverter(9.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34316	12041-10000-22518	11908 N ANDASOL AVE	91344	12	216B129   289	2606026046	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.28721	-118.51453	NEW11.28KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34317	12041-20000-18186	10100 W SANTA MONICA BLVD VTC-1553	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Approved	08/16/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24 lighting plan check for conference room, VTC-1553.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34318	19041-10000-03067	2710 E MEDIA CENTER DR	90065	1	150B213  3658	5442032006	[Q]M2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.1066	-118.24114	Energy plan check for constructing a new storage room located in an office building. Scope includes new lighting and equipment with a total area of 438-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34319	16041-20000-18091	5971 W VENICE BLVD	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Expired	06/26/2018 12:00:00 AM	ADDRESS	34.03865	-118.37272	Plan check for carport lighting.  50,116 sq ft of hardscape lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34320	12041-10000-21716	6290 W SUNSET BLVD UNIT #-B	90028	13	147A189   227	5546025029	(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	ADDRESS	34.09777	-118.32646	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT FOR EXISTING RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34321	18041-20000-48496	3305 W WOOD TER	90027	4	153A203   300	5434002007	R1-1	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Expired	05/20/2024 12:00:00 AM	ADDRESS	34.11227	-118.27781	Plan check for PV roof  mounted and Energy Storage System, PV system size: 5.2kW DC and 4.85kW AC CEC with 16 PV Modules and 1 inverter(5.0kW) and Tesla Energy Storage 13.5kW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34322	16041-10000-22397	3273 W CASITAS AVE 106-107,207	90039	13	153B209   393	5436002023	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.11638	-118.25202	First time T.I. to (e) core and shell office building (Building C) Approx 1,135 sf.  Main electrical system under separate permit. This is PC for T-24 only.B# 16016-10000-14612	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34323	17041-10000-29921	19881 W RINALDI ST	91326	12	213B113   304	2701040034	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.27607	-118.56788	PLAN CHECK FOR T24 ONLY FOR - interior and exterior alteration of existing retail area - TOTAL AFFECTED AREA = 9876 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34324	18041-20000-39634	5808 W SUNSET BLVD 8TH FLR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM			PC Info Complete	10/16/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check for Title 24 only in existing high-rise building, office T.I. on 8th floor L8 NEQUARD. Total area: 1624 sq ft. B#18016-10000-07243	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34325	13041-10000-35881	431 W 7TH ST 5TH AND 6T-H	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Closed	01/06/2016 12:00:00 AM	ADDRESS	34.04654	-118.25516	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT for Los Angeles Athletic Club. 5TH AND 6TH FLOOR. HISTORIC. TENANT IMPROVEMENT ON 5TH AND 6TH FLOOR OF 7 STORY HEALTH CLUB : NEW. LOCKERS, RESTROOMS, SHOWERS, SPA. & INSTALL  2 (N) STAIRCASE CONNECTING 5TH & 6TH FLOOR &  ADD. NEW RESTAURANT & BARBER SHOP & RETAIL STORE  TO (E) 6TH FLOOR.ALL overcurrent protective devices shall be series rating for 72kaic. Specification sheets to be provided to inspector in the field.BUILDING PC # 13016-10000-26283	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34326	13041-20000-33261	9175 N DE SOTO AVE	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.23782	-118.58874	SERVICE UPGRADE TO 600A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34327	12041-20000-19661	2917 E 1ST ST	90033	14	126A225    32	5180020031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			08/21/2012 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.04084	-118.20294	53 units apartment bbuilding variance for fire alarm on hand	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34328	15041-40000-11700	3701 W WILSHIRE BLVD 9TH FL	90010	10	132B193    27	5503029024	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.06188	-118.30708	REMODELING OF OFFFICESPLAN CHK IS FOR TITLE 24permit number was generated under San Pedro office.  However, it was generated in Metro	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34329	18041-20001-27441	1710 N MICHELTORENA ST	90026	13	145-5A205 351	5431026013	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.09182	-118.27293	09-07-2018 Changes to permitted set of plans, changes include remove 2 PV Module from Solar system. Upadate, PV module: 17, and  PV System size: 5.525kW.  Plan check only, permit covered under Master application.Fees $0.00 due to California Senate Bill 1222 and Assembly Bill 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34330	15041-20000-38551	6627 N NAGLE AVE	91401	2	180B157   385	2329021033	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.19099	-118.42374	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34331	16041-20000-03489	1030 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	33.79073	-118.29408	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR 1ST AND 2ND FLOOR. 14620 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34332	17041-20000-34316	11930 N CAPISTRANO LANE	91326	12	216B117    51	2872004015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.28949	-118.55189	PV1.  Install 4.6 kW roof mounted PV system.  Center-fed connection.  (14) modules with (1) 4kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34333	13041-10000-32223	5939 N COLBATH AVE	91401	2	177B153   961	2246003021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.17863	-118.43674	PV1, Install 5.5 kW DC roof-mounted solar array for a single family dwelling, interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US. 22 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34334	11041-20000-20220	1910 W COLORADO BLVD	90041	14	162A223   105	5686007005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			Corrections Issued	10/01/2011 12:00:00 AM	ADDRESS	34.13906	-118.20899	T.I.  Existing 7-11.  Replacing the existing light fixtures in the retail area, with LED light fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34335	15041-10000-20811	1875 CENTURY PARK EAST 17 FLR	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	PIN	34.06139196	-118.41527843	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMS.  PLANCHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1958. SCOPE OF WORK TO BE PERFORMED IN 17TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34336	12041-10000-18882	7348 N BELLAIRE AVE	91605	2	186B161   507	2324002030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.20515	-118.40928	New Fire alarm for an existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34337	15041-20001-35974	18857 W BRAEMORE ROAD	91326	12	216B121   190	2820015010	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM			Plans on Hold	11/03/2015 12:00:00 AM	ADDRESS	34.29062	-118.54451	Expedite per applicant request{{{{{{{Plan check for PV roof mounted system. System size: 3.8kW and 11 modules and 1 inverter(3.8kW). Standard plan is not being use.}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34338	12041-20000-05577	21001 W KITTRIDGE ST	91303	3	180B109   222	2148029035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	08/13/2012 12:00:00 AM	ADDRESS	34.19128	-118.5908	office and lab. t.i.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34339	19041-10000-24871	1302 S LA BREA AVE 201	90019	10	129B181   660	5070001036	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM			PC Info Complete	08/21/2019 12:00:00 AM	ADDRESS	34.04983	-118.34395	ENERGY PC FOR NEW RETAIL TI, SUITE 201. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 1911-SQ-FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34340	18041-20000-08274	9733 W MUSTANG WAY	91040	7	204B181   156	2549025031	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.25809	-118.34351	Plan check for a PV1 roof-mounted PV system. System size is 11.5 kWac and consists of (36) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34341	16041-30000-37175	11050 W RANDALL ST	91352	6	198B173   103	2408003041	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.23663	-118.37183	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34342	15041-30000-39808	14006 W RIVERSIDE DR Space FC9	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Title 24 plan check only.  Total area = 180 sq. ft.  T.I. to storage area for Burger King restaraunt.  New lighting, HVAC, and cooking equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34343	17041-10001-36352	3256 N DOS PALOS DR	90068	4	159B181   827	2429010023	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.12848	-118.34859	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34344	19041-10000-27666	6316 N TOPANGA CANYON BLVD #1390	91367	3	180B105    60	2146029022	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.18578	-118.60514	Energy plan check for a change of use from radio station to retail. Scope includes new lighting and equipment for the project.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34345	17041-20000-34750	15910 W VENTURA BLVD 8th Floor-Restroom	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.15561	-118.47969	Plan check for energy only. TI to existing commercial restroom on 8th floor of high rise building. New lighting (incl. emergency) - 161sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34346	16041-10000-25729	6600 N TOPANGA CANYON BLVD #1028	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Closed	09/14/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for title 24 only. TI for an existing retail space with 929 sqft. Scope includes new 100 A panel, new lights and new receptacles.**INTERIOR RENOVATION OF EXISTING RETAIL TENANT SPACE; NEW STOREFRONT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34347	12041-10000-02491	1700 E STADIUM WAY	90012	1	136-5A213  52	5415014900	PF-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.06815	-118.24238	Plan check for replacing FACP and new smoke detector. All devices are existing to remain. New FACP shall be compatible with existing devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34348	17041-20000-15185	8211 N REMMET AVE	91304	3	189B105    35	2110019022	[Q]CM-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.21802	-118.60044	New fire alarm system for commercial space (change of use from office to charter school).  (63) devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34349	13041-20000-16097	10435 W SANTA MONICA BLVD	90024	5	132B157   686	4326032031	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	PIN	34.05697834	-118.42553713	T24 FOR EXISTING 2 STORY OFFICE SPACE. SCOPE OF WORK ON THE SECOND FLOOR. 5006 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34350	17041-20000-38433	14555 W OSBORNE ST	91402	6	195B149    97	2639007021	R4-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Apartment			10/25/2017 12:00:00 AM	08/20/2018 12:00:00 AM		Issued	08/20/2018 12:00:00 AM	ADDRESS	34.23325	-118.44944	Plan check for energy only. Interior renovations to apartment building. New interior and exterior lighting. Total T24 area - 65,737sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34351	19041-10000-44063	5500 W 98TH ST Temp Power	90045	11	093B173   581	4128022906	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	12/07/2023 12:00:00 AM	ADDRESS	33.94764	-118.37749	Temp' power plan check for a new construction with a medium voltage 5kv 350MVA service supplying (3) 3000-Amp distribution panels. Scope including (3) 2MVA transformers, (35) 75kva transformer sypplying (35) 225-amp  panels and other associated equipment.Note. New parking structure with 3-story for LAX airport.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34352	15041-20001-28715	6011 S WEST BLVD	90043	8	105B185   477	4004031019	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	09/25/2015 12:00:00 AM	ADDRESS	33.98493	-118.33539	EXPEDITE FEESPV2 COMMERCIAL ROOFTOP SOLAR. PC FOR NEW SOLAR SYSTEM TOTAL OF 147 MODULES AND 3 CENTRAL INVERTERS. NEW SOLAR LOAD CENTER. INTERCONNECTED TO NEW SERVICVE PANEL (UNDER SEPARATE PERMIT) TOTAL SYSTEM SIZE 33KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34353	15041-20001-07895	6250 N TOPANGA CANYON BLVD BLDG F-SUITE 1510	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	08/26/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	08-25-2015 Change to approved set of plans. Changes include wattage of lighting fixture AE, add disconnect to  primary of the transformer, changes apply to delta 2 only. [[[[[TI to a new commercial building (juice bar). First time tenant. Plan check for power and energy. Total Sqft. 844]]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34354	16041-10001-23562	18000 W DEVONSHIRE ST	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM	ADDRESS	34.25698	-118.52508	CHANGE TO APPROVED SET OF PLANS. CHANGING POINT OF INTERCONNECTION FROM LOAD SIDE TO LINE SIDE CONNECTION. ALL CHANGES NOTED DELTA 3 ON PLANS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34355	17041-20000-13916	10902 N CARTWRIGHT DR	91311	12	210B113   259	2708030022	(T)(Q)RA-1-H, (T)(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Refund in Progress	06/19/2017 12:00:00 AM	ADDRESS	34.26876	-118.56617	PV1. ROOFMOUNTED SOLAR SYSTEM. AC STANDARD PLAN. SYSTEM SIZE: 8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34356	13041-20000-20350	7641 N QUAKERTOWN AVE	91306	3	186B113    90	2106005035	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.20959	-118.56986	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW USING 15 MODULES. CENTRAL TRANSFORMERLESS INVERTER, NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34357	16041-10000-02646	9254 N WINNETKA AVE BLDG C	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM			Permit Closed	08/30/2021 12:00:00 AM	ADDRESS	34.23884	-118.57087	NEW FIRE ALARM SYSTEM TO A NEW 5 STORY 188 UNIT MIXED USED COMMERICAL BUILDING (BUILDING C). SCOPE INCLUDES 502 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34358	17041-20000-06128	3737 S WATT WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.01921	-118.28872	Plan check for power only. Project site is an existing building on the USC campus. Project scope is medium voltage cabling to feed a new manhole which will refeed (2) building and new distribution equipment in building PHE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34359	18041-20000-42232	5757 W WILSHIRE BLVD 7th flr-north	90036	4	135B177   594	5508015009		Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.06259	-118.35341	ti to an existing commercial building.  adding new lighting new control to exisitng panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34360	10041-20000-09238	7266 W FRANKLIN AVE	90046	4	147B181    31	5548001195	R3-1	Central	Hollywood	Hollywood Hills West	YES	1899.03	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM			Corrections Issued	05/17/2010 12:00:00 AM	ADDRESS	34.10327	-118.3478	Plan check for T-24 general lighting for existing building. Plan check/permit under #10041-20000-09924	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34361	11041-10000-21370	23 E WINDWARD AVE	90291	11	106-5A143  30	4226008014	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			PC Approved	10/06/2011 12:00:00 AM	ADDRESS	33.98732	-118.47327	Installation of 4 strings of light above street from one building to another.  Applicant  has received revocable permit for encroachment.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34362	17041-20000-03311	4115 S REDWOOD AVE	90066	11	108B153   995	4230006017	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.99062	-118.44021	"Plan check for power only. New panel ""D"" and feeder only for existing commercial building (4). Change of use from auto repair garage to office. Building permit application #16016-20000-21225."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34363	14041-20001-29376	975 S FOSTER DR	90048	5	132B173   346	5088007033	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2014 12:00:00 AM			PC Approved	11/03/2014 12:00:00 AM	ADDRESS	34.05914	-118.36999	EXPEDITE PER APPLICANT REQUEST[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 10.32kW.48 EnPhase M215 microinverters and 48 260W pv modules across 3 strings (16+16+16).Derating the main breaker from 200A to 175A.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34364	11041-20000-22707	8759 N PARTHENIA PL Unit B	91343	6	195B145   478	2654012012	C2-1	North Valley	Mission Hills - Panorama City - North Hills			1175.20	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM			PC Approved	10/24/2011 12:00:00 AM	ADDRESS	34.22911	-118.46624	Plan check T24 Energy/emergency for TI of existing space Unit B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34365	14041-10000-31004	17401 W VENTURA BLVD	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.16136	-118.51189	Energy plan check for a gallery area located in a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34366	17041-10000-05714	13443 W REEDLEY ST	91402	6	192B157   455	2637013045	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.22362	-118.42623	Plan check for PV roof mounted system. System size 8.6kW with 27 AC modules connected to MSP.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34367	13041-10000-28935	6701 S CENTER DR WEST 2ND FLOOR	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	33.97907	-118.39369	PLAN CHECK FOR TITLE 24 ENERGY ONLY AND EMERGENCY LIGHTS FOR A TENANT IMPROVEMENT. HIGH RISE. SCOPE ON SECOND FLOOR. PERMIT TO BE PULLLED AT ELECTRICAL PLAN CHCECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34368	16041-10001-16918	3651 N MIMOSA DR	90065	1	154-5A217 252	5460004004	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.11615	-118.23065	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE NEW LOCATION OF SERVICE EQUIPEMENT AND INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34369	13041-10000-29160	1422 N CAPRI DR	90272	11	132B133   291	4425019003	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM			Reviewed by Supervisor	12/26/2013 12:00:00 AM	ADDRESS	34.0553	-118.50243	"NEW SERVICE FOR NEW 3-STORY ACCESSORY BUILDING. NEW MAIN SWITCHBOARD ""MSA"" IS 800A, 120/208, 3PHASE UNDERGROUND SERVICE. WILL BE BACKFEEDING EXISTING SERVICE. NEW GENERATOR/ATS TO BE INSTALLED SIZED AT 100KVA. EMERGENCY PANEL TO BE CHARGED ON FINAL FEE PERIOD, UPON DETERMINING THE SIZE OF THE NEW EM PANEL."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34370	18041-20000-24842	1234 S SPAULDING AVE	90019	10	129B177    92	5085025007	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.05346	-118.36096	Plan check for PV roof mounted system, system size: 11.02kW with 38 modules and 38 microinverters connected to 225 Main panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34371	15041-10000-05466	1410 S BARRACUDA ST	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.73195	-118.26357	Energy plan check for a warehouse by replacing existing lighting fixture with new LED fixture. Total area is 16500-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34372	18041-10000-23877	20929 W VENTURA BLVD	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	"TI IN AN EXISTING RESTROOM AT ""VALLEY COUNTRY MART"". T-24 ENERGY ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34373	11041-10001-12403	936 S BARRACUDA ST BERTH 302-305	90731										Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	ADDRESS	33.73774	-118.2636	INSTALL AND TERMINATE NEW 5KV RATED CABLES FROM EXISTING SUBSTATIONS TO EXISTING  CRANE POWER VAULTS (CPV) ALL NEW WORK IS BOLD-PRINTED ON THE PLANSNEW CONSTRUCTION FOR SHIP TO SHORE POWER AT BERTHS 302-305.  UNIT SUBSTATIONS ARE OVER 3 MVA AND ARE CHARGED UNDER PANEL BOARDS OVER 1200A, PLUGS TO SHIP (TOTAL OF 30) CHARGED AS NON-DWELLING POWER EQUIPMENT OVER 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34374	17041-20000-17034	1050 W CHILDS WAY B17G	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM			PC Approved	05/22/2017 12:00:00 AM	ADDRESS	34.02262	-118.29103	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 385 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34375	16041-20001-45103	1745 N WESTERN AVE	90027	13	148-5A193  44	5544005028	C4-1D	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			09/03/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.10305	-118.3096	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. RELOCATION OF HOUSE PANEL AND ADDING NEW DISCONNECT. <<<Plan check for power and energy. Project site is a 24-unit mixed use building: 3 levels of residential over 1 level of retail with 1 level of existing basement parking garage. Total lighting area = 32,574 sq. ft.Note: Building application has been generated under 16016-20000-21115>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34376	15041-10000-13186	633 W 5TH ST 71ST FLOOR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR POWER AND ENERGY. TI FOR RESTURANT. (71 RESTAURANT) . HIGH RISE BUILDING. TOTAL AREA 7573 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34377	16041-10000-05581	617 W 99TH ST	90044	8	093A201   399	6054023019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	33.94655	-118.28531	PV1, INSTALL 3.9 kW DC / 3.6 kW AC  ROOF-MOUNTED  SOLAR ARRAY ON A SINGLE FAMILY HOME(13) MODULES: SILEVO TRIEX U300 BLACK(1) INVERTER: ABB PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34378	19041-20000-48294	7348 N OWENSMOUTH AVE	91303	3	186B105   673	2111014003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.20418	-118.60141	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 6.84 KW DC/5.814 KW AC. SCOPE OF WORK CONSISTS OF (18) PV MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34379	13041-10001-30863	108 S KINGSLEY DR	90004	10	138B193   976	5517021033	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.07346	-118.30278	Expedited RSES plan check per applicant request. PV1, Install 7 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 28 modules: HANWHA # HSL60P6-PB-4-250TW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34380	19041-20000-36838	13730 W FOOTHILL BLVD	91342	7	222B153    42	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.30887	-118.43253	TENANT IMPROVEMENT TO (E) GROCERY STORE P.C FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34381	17041-10000-18471	5066 W ROMAINE ST	90029	13	144B193  1082	5537024005	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Apartment			06/02/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	07/10/2020 12:00:00 AM	ADDRESS	34.08831	-118.30255	Plan check for power and Title 24.  New 15 unit 2 story apartment building with 800 amp120/240 volt service.  Fire alarm variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34382	13041-10000-20814	499 N SAN FERNANDO ROAD	90031	1	141A219   137	5415003906	PF-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park, Greater Echo Park Elysian		1990.00	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Info Complete	10/24/2013 12:00:00 AM	ADDRESS	34.08114	-118.22579	NEW PRE FAB BUILDING FOR DEPARTMENT OF PUBLIC WORKS. 1 FLOOR. PLAN CHECK FOR POWER AND ENERGY. OUTDOOR LIGHTING. NEW SERVICE. 5 ESTATE COACH., 1 HOUSE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34383	19041-20000-34461	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	09/09/2022 12:00:00 AM	ADDRESS	34.13829	-118.34154	PV2.  Install 142.2 kW AC / 173.565 kW DC roof mounted grid tied PV system.  (399) modules with (3) 9 kW and (8) 14.4 kW rated inverters.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34384	18041-20000-30364	19222 W ROMAR ST	91324	12	204B117   324	2729027005	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.25533	-118.55209	Plan check for a PV1 roof-mounted PV system. System size is 16.83 kWdc/15.71 kWac-CEC and consists of (2) inverters, (51) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34385	16041-20000-27071	11510 N MANCHESTER WAY	91326	12	213B113   415	2701087040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.28295	-118.57401	PV1.  Install 5 kW AC rated PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34386	19041-10001-44526	17347 W SAN FERNANDO MISSION BLVD	91344	12	210B129   322	2711010015	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.27227	-118.51262	EXPEDITE FEESPV1, NEW ROOFTOP SOLAR SYSTEM, SYSTEM SIZE IS 15.75KWac/17.75KWdc.SCOPE OF WORK INCLUDES 50 MODULES (SOLARIA POWER XT-355R-AC) WITH MICROINVERTERS (IQ7PLUS-72-ACM-US), LEADING TO A COMBINER BOX, NOTE THE MAIN SERVICE PANEL UPGRADE IS COVERED UNDER SEPERATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34387	15041-10006-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Changes to approved set, Changes include revised and new circuits. All changes are made under delta 40.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34388	18041-20000-00583	16080 W COLUMBUS LANE	91343	12	192B141   566	2673023033	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.22309	-118.48368	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.4 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34389	14041-20000-17061	1600 N AVENUE 54	90042	14	156A227   111	5479010012	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.1228	-118.19864	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS SYSTEM. USING POWER OPTIMIZERS. USING 16 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34390	16041-20000-39631	8411 N CAPISTRANO AVE	91304	12	192B101   339	2004011002	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.22314	-118.61697	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.6.24kW ungrounded system. (26) EnPhase M250 microinverters. (26) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34391	18041-10000-21090	324 W AMAR ST	90731	15	018B201   110	7449003051	R2-1XL	Harbor	San Pedro	Central San Pedro	YES	2962.10	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	33.74793	-118.28415	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW  AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34392	19041-20000-09118	425 N PARKWOOD DR	90077	5	141B153    67	4358002011	RE20-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM			Not Ready to Issue	11/05/2019 12:00:00 AM	ADDRESS	34.0855	-118.43429	new sfd 800 amp service.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34393	17041-10000-24513	2014 E 15TH ST	90021	14	120A215   209	5167019051	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.02161	-118.23548	Plan check for title 24 only  in existing space, remove metal halide outdoor fixtures and replace with new LED fixtrues. Total area: 8,850 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34394	18041-20000-16245	1110 W 48TH ST	90037	9	111B197   823	5017021010	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	33.99949	-118.2943	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (18) modules, (1) load center, and (1) auto-transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34395	18041-10000-14181	400 S ROSSMORE AVE	90020	4	135B185   242	5505016001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM			Corrections Issued	04/18/2018 12:00:00 AM	ADDRESS	34.0668	-118.32714	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.8 KW.(48)  MICRO-INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34396	19041-20000-00236	17566 W TUSCAN DR pv1	91344	12	222B129   246	2601044012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.30255	-118.51621	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34397	15041-10000-15681	4455 N LANKERSHIM BLVD	91602	4	165B173   141	2423009050	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.15185	-118.36703	Commercial TI of (E) bank for (2) interior eATM machines.  Relocate (E) power/data per plan and install new light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34398	14041-10000-17237	12300 W WILSHIRE BLVD 210	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.04245	-118.46922	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 210. [[[NOT A HIGHRISE PER APPLICANT. ]]]]]   3024 SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PUILLED UNDER 14041-90000-16857Remodel of an existing suite	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34399	19041-10001-41870	626 S LANDFAIR AVE	90024	5	135B149   325	4363006007	[Q]R4-1VL	West Los Angeles	Westwood	North Westwood		2653.05	Electrical	Electrical	Apartment			10/15/2019 12:00:00 AM			PC Approved	02/28/2020 12:00:00 AM	ADDRESS	34.06671	-118.44879	EXPEDITE FEES PER APPLICANT REQUESTPV2. NEW COMMERICIAL SOLAR SYSTEM. 15.3 KW dc. (51) HYUNDAI SOLAR MODULE HiS-S300RG (300 W)(51) SOLAREDGE POWER OPTIMIZER P320 (320 W)(1) SOLAREDGE INVERTER SE11400H-US[240V\[S|1]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34400	16041-30000-20849	2029 S SAWTELLE BLVD	90025	11	126B153   804	4261033014	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.04015	-118.44316	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant. Total lighting area = 13,403 sq. ft.Note: Building application has been generated under 16014-30000-00898	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34401	13041-20000-22961	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.09676	-118.29487	NEW FIRE ALARM SYSTEM. 20 DEVICES. NEW PANEL. NEW SMOKE DETECTORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34402	14041-10000-25691	12526 W FIELDING CIR	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	33.97833	-118.41207	PLAN CHECK FOR FIRE ALARM SYSTEM FOR APARTMENT COMPLEX WITH MULTIPLE BUILDING WITH MULTIPLE ADDRESSES. THIS IS BUILDING 5 OF 7. ALL BUILDING UNDER ONE SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34403	13041-10000-16236	37 E WASHINGTON BLVD	90291	11	105A145   428	4226023015	C4-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	PIN	33.97981798	-118.4659699	TENANT IMPROVEMENT OF AN EXISTING SPACE. INSTALLATION OF A NEW 600 A SWITCHGEAR. RESTAURANT WORK.  methane zone. pc for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34404	18041-20001-04492	20510 W WELLS DR	91364	3	169-5A111 136	2174014026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.1573	-118.57964	04/20/2018 Changes to an approved set of plans. System size has been reduced to 8.5 kWac and module and micro-inverter count is now (37). Standard plan is being used.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 9.2 kWac and consists of (40) modules, (40) micro-inverters, and (1) load center. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34405	16041-10000-03607	21176 S WESTERN AVE	90501	15	051B193   222	7349014012	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	33.83759	-118.30899	PC FOR POWER AND ENERGY. NEW STURBUCKS STORE.  NEW 600A SERVICE. TOTAL AREA INCLUDING INDOOR, FACADE, CANOPY AND SITE LIGHTING : 12375 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34406	19041-10001-23243	1547 S CORINTH AVE	90025	11	129B149   434	4261004903	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM			PC Approved	10/30/2019 12:00:00 AM	ADDRESS	34.04653	-118.45014	change to an approved set, relocating of 4 EV chargers and updating voltage drop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34407	11041-20000-09255	127 S SAN VICENTE BLVD Bulletin-58TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Closed	02/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin # 67-cs	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34408	12041-10000-12029	1600 S BROADWAY	90015	9	124-5A207 335	5133006006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.03396	-118.26352	800A service upgrade to an existing commercial building with an AT&T cell tower.  New panels, lighting, and circuits for equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34409	14041-20000-00932	5732 N CHICOPEE AVE	91316	5	174B129   348	2254020014	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Expired	03/23/2016 12:00:00 AM	ADDRESS	34.17506	-118.51214	NEW ROOF MOUNTED PV SYSTEM FOR SFR.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34410	12041-10000-20308	901 W WASHINGTON BLVD	90015	1	124-5A203  18	5124017001	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2242.00	Electrical	Electrical	Public Safety Only			08/28/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Closed	09/19/2012 12:00:00 AM	ADDRESS	34.03718	-118.27781	New fire alarm system for a church.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34411	17041-20000-07882	17031 W GUNTHER ST	91344	12	213B133   130	2607002033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Issued	04/14/2017 12:00:00 AM	ADDRESS	34.28343	-118.50347	pv1install roof mounted pv system with battery backup connect to msp.This system is an addition to an exisitng system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34412	17041-10000-22683	900 W WILSHIRE BLVD	90017	14	130-5A209 239	5144006901	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.05001	-118.25963	FULL FLOOR TI FOR 16TH AND 17TH FLOORS. OFFICES AND SOME ASSEMBLY UPGRADES. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34413	15041-10000-35086	111 E UNIVERSAL HOLLYWOOD DR 14th fl	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	alterations in office space-plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34414	16041-10000-02674	6312 S 7TH AVE	90043	8	105B189  1205	4007012025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	33.98255	-118.32439	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.6KWac. (15)MODULES-SILEVO # TRIEX U290 BLACK(1)INVERTER-ABB #PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34415	12041-20000-26802	2844 W ROWENA AVE Lot 5	90039	4	151-5A207 173	5434033010		East Los Angeles			YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.10762	-118.26616	Enphase system on roof of single family dwelling. Address is also 2839 Buzz Ct.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34416	13041-10000-15088	2001 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	PIN	34.06587468	-118.19737837	PLAN CHECK FOR POWER AND ENERGY, CONVERTING AN EXISTING OFFICE TO A SERVER ROOM. PER APPLICANT: CURRENTLY 7 DAYS INTO A 30 DAY METER READING ON THE 2000 A BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34417	18041-20000-37834	13444 W TREGO ST	91342	7	231B157    57	2582019025	RE15-1-H	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.32905	-118.42537	Plan check for battery(LG Chem Resu10) installed into existing PV system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34418	14041-10000-15903	5213 E MONTE VISTA ST STE# A	90042	1	151-5A227 248	5469019024	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	Apartment			06/13/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.10885	-118.2008	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34419	19041-10000-44391	900 S KENMORE AVE	90006	10	132B197   797	5094023040	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Apartment			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	07/14/2021 12:00:00 AM	ADDRESS	34.05574	-118.29639	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS A NEW FIRE ALARM PANEL WITH FOUR POWER SUPPLIES, AND IN TOTAL 111 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34420	16041-20000-45562	1335 S ABBOT KINNEY BLVD	90291	11	108B145  1240	4239027009	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	33.99097	-118.46678	Plan check for energy only. Tenant improvement to (e) retail space. New lighting (incl. emergency) and receptacles. 1,730sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34421	13041-20000-15830	9337 GLORY AVE PV-1	91042	2	198B201   345	2572044009	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	PIN	34.23851513	-118.27985693	PV-1. 4 strings per inverter. 200A service upgrade, one 8kW Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34422	13041-10000-21088	255 S GRAND AVE	90012	14	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.05332	-118.25122	TITLE 24 PART 6 ENERGY EXPRESS PERMIT FOR  516 units to be installed on existing branch circuits (for inspection fees). Removal and replacement of wall mounted light fixtures (fluorescent to LED) of common area corridors of highrise building (3rd floor to 27th floor - no 13th floor).  Combined corridor area revised to ~34,000 sq ft. All exit signs are existing to remain. Title 24 plan check only.Generator load calculations: LED ~20W Fixtures in corridor are lower wattage than lights being replaced. no added load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34423	10041-10000-18167	18448 W OXNARD ST	91356	3	177B125   702	2157001151	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	34.17976	-118.53503	INSTALL A NEW SPRINKLER MONITOING SYSTEM IN A TWO STORY OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34424	14041-10000-35495	11912 W LAURELWOOD DR	91604	2	162B169  2230	2369017042	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Apartment			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.14191	-118.39187	Installation of new fire alarm system in new 9 unit apartment building.  (62 devices, 1 panel)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34425	14041-20000-29101	4810 E SONATA LANE	90042	1	151-5A223 138	5471017040	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.10934	-118.2095	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTECONNECTED WITH MAIN SERVICE PANNEL(35) CANADIAN SOLAR MODULES MODEL NO. CS6P-250(1) SOLAR EDGE TRANSFORMERLESS INVERTER MODEL NO. SE5000A-US(35) POWER OPTIMIZERS SOLAR EDGE P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34426	18041-20000-10493	9907 N DE SOTO AVE	91311	12	201B109    88	2747002031	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Issued	04/19/2018 12:00:00 AM	ADDRESS	34.25043	-118.58875	PLANCHECK FOR POWER AND ENERGY. NEW LAUNDRY LOADS TO EXISTING SERVICE. NEWLY CONNECTED LOAD > 400AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34427	15041-20000-31336	16704 W BAHAMA ST	91343	12	195B137   279	2688043008	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Expired	10/18/2017 12:00:00 AM	ADDRESS	34.23304	-118.4968	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34428	18041-20000-21108	23052 W HATTERAS ST	91367	3	174B097   190	2041016028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Re-Activate Permit	04/24/2019 12:00:00 AM	ADDRESS	34.17538	-118.62942	PV1.  Installation of a roof mounted grid tied PV system.  PV system is partially installed on open trellis cover.  (35) modules with (2) 5 kW rated string inverters.Note: Building permit has been issued under 17014-20000-04755	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34429	15041-20000-33093	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for PV 2 roof mounted system on commercial building (Net metering). System size:140kW  and 528  modules.NOTE: FEES $0 DUE TO SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34430	11041-20000-20189	853 W MIRAFLORES AVE	90731	15	021B197   553	7447020035	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2963.00, 2965.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	12/06/2011 12:00:00 AM	ADDRESS	33.75267	-118.29605	New 11.28 KW roof mounted PV system on a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34431	16041-10000-41409	1716 S SEPULVEDA BLVD 104	90025	5	129B153   901	4323020003	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.0471	-118.44357	PC FOR TITLE 24 FOR A NEW RESTAURANT.NON HIGH RISE BLDGTOTAL AFFECTED AREA 1098 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34432	13041-10000-17676	890 N TOYOPA DR 5-21-5-24	90272	11	126B129    71	4411001013	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.04436	-118.52418	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING FOR A TENANT IMPROVEMENT. CLASSROOMS AND OFFICES AND STORAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34433	19041-20002-00074	18400 W RINALDI PL	91326	12	210B125    98	2715026057	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	34.27487	-118.53445	Revised equipment locations.  $0.00 plan check fee due to California Senate Bill 1222 and AB 1414(((PV1.  Install 13.680 kW DC roof mounted grid tied PV system.  (38) AC modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34434	13041-20000-31670	1232 S LA CIENEGA BLVD	90035	5	132B173  1104	5087003006	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.05473	-118.37596	T24 FOR EXISTING OFFICE/RETAIL. 7098 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34435	15041-10000-22720	1344 W 37TH PL	90007	8	117B197   128	5040011008	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.01982	-118.2988	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.9KW INTERCONNECTED WITH MSP.(18) TRINA SOLAR TSM-250 MODULES(18) ENPHASE M215 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34436	12041-10000-02396	5900 W WILSHIRE BLVD 610	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.06237	-118.35809	T.I. to an existing office space on the 6th floor.  Change to lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34437	17041-20000-34575	14025 W MOORPARK ST	91423	4	165B153   270	2271013010	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Apartment			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.15056	-118.43852	Plan check for energy only. Replacing existing lighting in apartment corridors. New wattage is reduced more than 35% per 141.0(b)2I.ii.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34438	16041-10000-07061	520 N TOYOPA DR	90272	11	123B129    49	4411015003	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM			PC Info Complete	03/23/2016 12:00:00 AM	ADDRESS	34.03693	-118.51952	SINGLE FAMILY DWELLING WITH ATTACHED GARAGE  & HABITABLE BASEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34439	19041-10001-02914	2727 N ROSCOMARE ROAD	90077	5	156B145    98	4378013004	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM			PC Approved	04/03/2019 12:00:00 AM	ADDRESS	34.12572	-118.46383	Expedite per applicant request.(((Plan check for a 14.0 KW AC roofmounted system. Scope includes (49) module and IQ-7Plus microinverters interconnecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34440	19041-20000-24165	24344 W CLEAR CREEK PL	91304	12	192B089   211	2017040008	RE9-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.21903	-118.65625	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.88KW DC/5.2KW AC. SCOPE OF WORK INCLUDES (9) SC-B2 PV MODULES AND A DELTA SOLIVIA 5.2 TL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34441	13041-10000-01640	4445 N ROMERO DR	91356	3	165B117    74	2178026003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.15133	-118.55621	PV1 ROOF MOUNTED SOLAR INSTALLATION ON SINGLE STORY FAMILY DWELLING. USING 51 MODULES IN FOUR STRINGS, AND TWO TRANSFORMERLESS (UNGROUNDED) INVETERS. SYSTEM SIZE IS 12.24 KW [MODULES: TRINA SOLAR # TSM-240PA05 |||| SOLAREDGE # SE5000A-US AND SOLAREDGE # SE6000A-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34442	15041-10000-16729	5356 S VICTORIA AVE	90043	9	099B205   912	6030032021	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	33.99338	-118.33202	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.  (21) KYOCERA 260 MODULES(1) ABB PV1 5.0 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34443	10041-10000-24518	710 N KELLER ST	90012	14	130-5A217  37	5409021902	PF-1XL	Central	Central City North			2060.20	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Expired	09/11/2013 12:00:00 AM	ADDRESS	34.05361	-118.22952	NEW SERVICE /SWBD \PNL BOARDS FOR  THE New Maintenance Yard.  Plan Check is Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34444	14041-20000-24825	7010 S HOOVER ST	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 8 modules in total. System connects to unit subpanel. This application is for House panel. total system size 2kw AC. zoning clearance shall be applicable for all solar installations on this building.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34445	16041-10000-28670	5955 W SATURN ST	90035	10	129B173   629	5068012039	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.05039	-118.3702	Plan check for Fire alarm system in 29 units appartment 4 story building. Total Fire alamr devices: 117 and 1 new FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34446	16041-10000-01887	6353 W YUCCA ST	90028	13	150A187   334	5546002001	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Expired	02/15/2018 12:00:00 AM	ADDRESS	34.10412	-118.32845	Power plan check for a service upgrade from 400A to a 800A. (2) new panels also added for future tenants.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34447	16041-20000-15401	15727 W VANOWEN ST	91406	6	183B141   729	2224034012	C2-1VL, R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.19405	-118.47598	Plan check Title 24 only for addition of recreation room in existing space. Indoor area: 346 sqft  and outdoor area: 410 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34448	13041-20000-20519	17100 W VENTURA BLVD	91316	5	168B133    80	2289005012	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.16003	-118.50552	energy plan check remodel. plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34449	12041-10000-28191	1900 S AVENUE OF THE STARS 970	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI TO EXISTING OFFICE. 9TH FLOOR HIRISE METHANE ZONE. PC FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34450	14041-10000-25512	3071 W SAN FERNANDO ROAD	90065	13	153A213    76	5458009018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.11454	-118.24533	Title 24 plan check only.  TI to existing commercial space including lighting and new subpanels (Total connected load = 400 A)  Total area = 6,795 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34451	17041-10001-10949	500-502 N LA BREA AVE	90036	5	141B181  1181	5525020010	(T)(Q)RAS4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Info Complete	08/30/2017 12:00:00 AM	ADDRESS	34.0804	-118.34385	Plan check for T24 only and additional permit to master permit# 17041-10000-10949	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34452	12041-20000-26021	134 S ROBERTSON BLVD	90048	5	138B169   438	4334005006	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM			PC Approved	11/09/2012 12:00:00 AM	ADDRESS	34.07445	-118.38361	Plan check for energy only. Added track lighting. 1212 sqft. Emergency lighting and exit signs are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34453	15041-20000-23655	16600 W SHERMAN WAY Ste 170	91406	6	183B137    71	2225005010	(Q)CR-1VL, (Q)P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.20096	-118.495	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,470 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34454	10041-20000-05608	5900 W WILSHIRE BLVD 22nd  flr.	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/05/2010 12:00:00 AM	ADDRESS	34.06237	-118.35809	s.2210 office t.i.Energy, emergencyReqquest for Modification to sepsrate Fire Alarm system filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34455	17041-20000-19161	700 S FLOWER ST Suite 700	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for energy only. TI to existing office on 7th floor of high rise building (Suite 700). New lighting (incl. emergency) - 5,785sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34456	16041-10001-30063	3329 W SUNSET BLVD	90026	13	144A203   356	5426006008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM			PC Approved	01/23/2017 12:00:00 AM	ADDRESS	34.08729	-118.27551	Plan check only. Changes to approved set per inspection request.Changes include addition of shut off controls and removing fixtures form corridorPermit was pulled under original permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34457	17041-10001-44988	6423 N HESPERIA AVE	91335	3	180B125   614	2123015002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM			PC Approved	12/29/2017 12:00:00 AM	ADDRESS	34.18746	-118.52631	Supplemental application for PV expedite.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34458	19041-10000-25404	21340 W DEVONSHIRE ST	91311	12	204B105   323	2747011061	QC4-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.25707	-118.59648	T-24 PLAN CHECK FOR RAMADA HOTEL COMMON AREAS TI. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 3752 SQ.FTSCOPE ALSO INCLUDE RELOCATING 4 SUB-PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34459	15041-10000-32635	811 W 7TH ST 11TH FLR	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.04908	-118.25911	T-24. PC FOR ENERGY ONLY.  FULL FLOOR TENANT IMPROVEMENT AT THE 11TH FLOOR OF AN EXISTING OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTING AND TWO NEW PANELS. TOTAL AREA IS 7738 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34460	14041-10000-09249	650 S WESTERN AVE	90010	10	132B193    69	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.06143	-118.30892	TENANT IMPROVEMENT.   CHANGE OF USE FROM RETAIL TO RESTAURANT.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34461	15041-10000-10954	540 S COMMONWEALTH AVE	90020	13	135A201   133	5077005028	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Public Safety Only			04/13/2015 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.06395	-118.28551	METHANE MITIGATION SYSTEM FOR 2-STORIES PARKING STRUCTURE; UPPER FLOOR IS A SOCCER FIELD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34462	19041-20000-06977	15303 W VENTURA BLVD STE 300	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	Replacement of 800A ATS used for optional standby system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34463	19041-10000-11364	17000 S VERMONT AVE	90247	15	066B197   223	6121015031	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Issued	03/29/2019 12:00:00 AM	ADDRESS	33.87666	-118.29088	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34464	13041-10001-12075	6151 W PICO BLVD	90035	5	129B173    23	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.05337	-118.37542	THIS IS A ONE STORY RETAIL, TITLE 24 ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34465	18041-20000-20271	5722 S BANDERA ST	90058	9	108B213   579	5105024024	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	33.99051	-118.23993	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34466	13041-10002-04928	1375 N WESTERN AVE	90028	13	147A193   196	5544030055	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM			PC Approved	08/06/2014 12:00:00 AM	PIN	34.09622604	-118.30960264	(((8/6/2014 Supl. app. for title 24 plan check only.  Previous application was for power only.  Inspector requested title 24 approvial prior to final.  Minor changes to lighting since last approved set - wattage of LED strip lighting reduced)))SERVICE UPGRADED TO 800A OVERHEAD;NO CHANGES TO THE LOAD(((((((((PC IS FOR T24 ENERGY. BUILDING ADDITION AND RENOVATION FOR AN EXISTING RESTAURANT; EXPAND RESTAURANT INTO (E) POST OFFICE (CHANGE OF USE FROM POST OFFICE TO RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34467	18041-20000-07816	8612 N DARBY AVE	91325	12	195B125  1024	2786003007	P-1VL, [Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.2269	-118.53373	Replacement of 8 LED lights and 100A subpanel in (E) body shop.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34468	12041-20000-25405	12161 W SATICOY ST	91605	6	186B165   215	2307015006	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.20863	-118.39866	PANEL UPGRADE AND BRANCH CIRCUIT FOR MONITORING SYSTEM HAVE BEEN ADDED TO THE PERMIT FEE (AND PAID FOR). New rooftop pv system for an existing single family residence.   System is ungrounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34469	15041-10007-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	11/03/2016 CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REVISED CIRCUITS TO INCLUDED ROOMS ON PANEL SCHEDULE, ADDITION OF NEW BRANCH CIRCUITS, ADDING, REMOVAL OR RELOCATION OF RECEPTACLES ON FLOOR PLAN. CHANGES HAVE BEEN CLOUDED AS (DELTA 38 - ASI-200/200R1) ON PLAN.NOTE : PACKAGE #6.INCLUDED ARE DELTA # 35 CHANGES(APPROVED SET).DELTA # 37 CHANGES SUBMITTED 11/03/2016DELTA # 36 CHANGES ARE STILL IN PLAN CHECK UNDER APPLICATION 15041-10004-14585	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34470	13041-20000-22843	11527 N VENEZIA WAY	91326	12	213B109   531	2701070038	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.28087	-118.58452	pv1 single family dwelling. total system size 3.6 kw using 18 modules. using transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34471	16041-10001-17393	6230 W YUCCA ST	90028	13	148-5A189   5	5546030029	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.10353	-118.32572	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 REVISION. CHANGE TO WAY MAN LIFT DISTRIBUTION IS MADE. CHANGE ONE FEEDER TO NOTE ELEVATOR. PC ONLY. PERMIT FEES UNDER MASTER PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34472	14041-20002-11429	6615 N ALLOTT AVE	91401	2	180B157   403	2329009038	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.19075	-118.42822	"Changes from previously approved plans.  Relocate 4 modules on the roof.  No changes in module and inverter model number.  Note: All permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****"" 0 permit fee due to solar ordniance ""PV1.  Install 11.00 kW roof-mounted PV system, interconnect with main service panel.  (44) modules.  (2) transformerless inverters: SolarEdge SE5000A-US"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34473	17041-10000-06595	13207 N GLADSTONE AVE A-B	91342	7	225B157   700	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.31086	-118.4288	PC FOR POWER AND ENERGY. TI  IN A RETAIL STORE. EXISTING SERVICE WITH NEW MAIN SWITCHGEAR 1200A, ADDITION OF 5 NEW PANELS. TOTAL AREA 21688 SQ FT. PERFORMANCE METHOD.B # 17016-40000-04594	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34474	13041-10000-32755	1500 W PACIFIC COAST HWY BLDG H	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING HTHIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34475	18041-10000-34190	1301 W 228TH ST	90501	15	045B197    30	7347013033	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	33.81911	-118.29931	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34476	19041-20000-27885	9601 N KENTLAND AVE	91311	12	201B097   146	2727002004	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.24478	-118.61809	Plan check for PV roof mounted system, system size: 11.84KW with 37 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34477	16041-10000-45549	4270 N LANKERSHIM BLVD	91602	4	165B177   746	2423023032	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.14767	-118.36399	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34478	15041-20000-38647	333 S HOPE ST 57th fl	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 only for existing space in high-rise storage office. Total area: 2,850 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34479	15041-20000-15904	11620 W WILSHIRE BLVD 718	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Issued	09/01/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	Plan check for power and Title-24.  Total area = 2,723 sq. ft.T.I. to medical office.  Two new panels connected to step down transformer.  Lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34480	14041-10000-32941	1113 S HOPE ST	90015	14	127-5A207 262	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.04215	-118.26348	plan check for energy only . 2013 T24 standards. CHANGE OF USE FROM RETAIL TO RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34481	15041-10000-04696	801 S OLIVE ST	90014	14	127-5A209  31	5144019018	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			02/26/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.04514	-118.25715	PLAN CHECK FOR POWER AND ENERGY FOR NEW 33-STORY TYPE 1A MIXED USE BUILDING WITH 363 RESIDENTIAL UNITS AND 10,000 SF COMMERCIAL USES OVER 2-LEVEL  SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34482	12041-10001-18807	240 E 6TH ST	90014	9	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.0435	-118.24761	Install a new fire alarm system in an existing apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34483	10041-10000-21744	1311 W 37TH ST	90007	8	120B197  1150	5040009028	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Public Safety Only			11/01/2010 12:00:00 AM	11/01/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	34.02109	-118.29795	NEW FIRE WARNING SYSTEM FOR A 2-STORIES BUILDING HOUSING THE SENSHIN TEMPLE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34484	12041-10000-29343	1301 W 58TH ST	90037	9	108B197  1272	5002013002	RD1.5-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM			Reviewed by Supervisor	05/23/2014 12:00:00 AM	ADDRESS	33.98998	-118.29818	New 7.8 kw roof mounted PV for a duplex.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34485	18041-10001-24348	11244 W BRIARCLIFF LANE	91604	2	156B169   197	2381020019	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM			PC Approved	08/10/2018 12:00:00 AM	ADDRESS	34.12627	-118.38058	FEE EXPEDITEPLAN CHECH FOR ROOF MOUNTED PV SYSTEM FOR 65 MODULES WITH MICROINVERTERS(IQ7-60-US). SYSTEM SIZE = 15.6KVA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34486	14041-10000-15647	1709 W 8TH ST	90017	1	130-5A205  64	5142014044	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Apartment			06/11/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.0531	-118.27354	UPGRADING EXISTING FIRE ALARM SYSTEM. 402 DEVICES AND 1 PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34487	19041-20000-09956	11150 W VENTURA BLVD	91604	2	162B173   333	2378009004	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	11/10/2022 12:00:00 AM	ADDRESS	34.14151	-118.37371	new assembly hall, article 518, plan check for power and energy.building application number 11010-20000-00581	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34488	17041-10000-18498	1514 W 213TH ST	90501	15	051B193   474	7349018015	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Expired	10/10/2023 12:00:00 AM	ADDRESS	33.83536	-118.30441	ROOF MOUNTED SOLAR SYSTEM FOR A SINGLE FAMILY DWELLING. (8) MODULES AND A SMA 3.8KW INVERTER. TOTAL SIZE 3.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34489	19041-10000-36143	23555 W WINDOM ST	91304	12	186B093   351	2027036011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.20561	-118.64049	[EPLAN] PLAN CHCK FOR ROOF MOUNTED 9KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(NINGBO SOLIS-1P9K-4G-US) WITH 34 MODULES USING RAPID SHUTDOWN DEVICE. MAIN BREAKER DERATING UNDER DEPARATE PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34490	12041-10000-22230	5217 N WINDERMERE AVE	90041	14	163-5A221 175	5671019005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.14221	-118.21718	PV1 INSTALLATION OF A ROOF-MOUNTED  3.43KW PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34491	15041-10000-25386	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	ARAEA C3 LEV 05 : FOOD AND BEVERAGE AREAS T72-FB AND T73-FB ADDING LUMINAIRES PLAN CHK IS FOR TITE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34492	13041-20000-28560	10348 N STAFFORD LANE	91311	12	204B113    84	2707015015	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.25886	-118.57759	New 10.2 kw UNGROUNDED rooftop PV system for an existing single family dwelling.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34493	17041-10000-18314	2002 W SLAUSON AVE	90047	8	105B189    20	6001001900	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	33.98891	-118.31398	Installation of new solar PV system on two new carports and one new office building roof.  260 modules connected to 5 new inverters which feed 200 amp 208/120 volt solar only load center.  Supply side tap connection.  Total system size = 56 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34494	18041-20001-40868	13568 W SAYRE ST	91342	7	225B157   360	2510016009	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.31484	-118.42827	Revisions to approved plans.  Approval for contractor design-build plan set.  Wire detail changes relative to original online permit set.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34495	17041-10002-44422	5027 N MONTEZUMA ST	90042	1	151-5A225  52	5469009037	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.11101	-118.20559	CHANGES TO APPROVED SET TO REFLECT CHANGE IN SIZE TO PV MODULES FROM 305W TO 295W.THIS IS PLAN CHECK ONLY. PERMIT FEES PAID UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34496	15041-30000-39670	6060 W CENTER DR 2nd Floor	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			PC Approved	11/24/2015 12:00:00 AM	ADDRESS	33.97602	-118.39073	Title 24 plan check only.  Total area = 21,070 sq. ft.   T.I. to existing commercial office highrise.  Subpanels to remain existing (new load < 400 A).  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34497	15041-10000-01796	139 1/2 N LARCHMONT BLVD	90004	4	138B189   807	5515019019	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.07418	-118.32383	TI to (E) restaurant space for proposed incoming coffee shop.  Plan check for energy.  Approval for clearance imposed by ordinance no. 168334 obtained under 14016-10000-26274	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34498	19041-20000-07073	6417 W SAN VICENTE BLVD	90048	5	132B173    20	5088012015	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.062	-118.36823	Addition of 13.5 kWh energy storage system to (E) 7.6 kW rated PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34499	16041-30000-18943	8523 N FAUST AVE	91304	12	192B097    71	2004013007	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.22517	-118.62051	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34500	11041-10001-08983	1143 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM			PC Approved	05/20/2011 12:00:00 AM	ADDRESS	34.03005	-118.22064	TI, CREATE NEW 2-STORY OFFICE SPACE IN EXISTING WAREHOUSE.  OTC PLAN CHECK FOR T-24 WITH EMERGENCY LIGHTING ONLY.  SUBJECT TO INSPECTOR, FULL PLAN CHECK MAY BE REQUIRED. change of wattage and addition of lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34501	18041-10000-39877	1750 S MALCOLM AVE	90024	5	129B153   314	4325024009	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	06/03/2021 12:00:00 AM	ADDRESS	34.05111	-118.43516	New fire alarm system in the bulding.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34502	14041-10001-18002	8018 N CANTALOUPE AVE	91402	6	189B153   366	2213013022	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM			PC Approved	07/14/2014 12:00:00 AM	ADDRESS	34.21672	-118.43362	Expedited	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34503	19041-10000-39591	200 WORLD WAY T.I.	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	10/01/2020 12:00:00 AM	ADDRESS	33.94558	-118.4039	T2 DELTA SKY ZONE & PET RELIEF RELOCATION IN TERMINAL OF 2 OF LAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34504	10041-20000-19165	7301 N MEDICAL CENTER DR #550	91307	3	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	34.20262	-118.62963	T.I. to existing building of a Physical Therapy.  No surgery equipment install.  Install new branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34505	18041-10002-37130	7516 S OGELSBY AVE	90045	11	102B165   587	4110009024	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM			Reviewed by Supervisor	10/11/2018 12:00:00 AM	ADDRESS	33.97409	-118.39997	NEW ROOF MOUNTED 10.075 KW PV SYSTEM WITH 13.5KW ENERGY STORAGE ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34506	17041-20000-04342	2134 W SUNSET BLVD ste e	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.07723	-118.26485	ti to an existig single story restaurant.  adding new lighitng new controls to new panel.  newly connected load < 400 amps.  plan check for energy only.  total square footage 686	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34507	15041-10000-31188	9840 N MELVIN AVE	91324	12	201B117   152	2761033019	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM			Verifications in Progress	11/13/2015 12:00:00 AM	ADDRESS	34.24926	-118.56002	INSTALLATION OF 12.6KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF SFD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34508	19041-10000-22522	550 S HOPE ST # 410	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34509	16041-10000-42318	6115 N VAN NUYS BLVD	91401	6	177A151    41	2241021017	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.18132	-118.44899	Plan check for Title 24 only in existing space remove HID fixtures and replace with new LED lighting fixtures. Total area: 25,275 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34510	15041-10000-33404	1100 N FIGUEROA ST	90744	15	033B201   634	7415020040	R1-1XL	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Issued	12/02/2015 12:00:00 AM	ADDRESS	33.7844	-118.28029	PC for power only, 1200 amp temporary power pole for a new construction. No load added. Scope includes new switch gear and transformer only based on designed load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34511	19041-10000-14896	6711 S SEPULVEDA BLVD	90045	11	102B165    39	4110001004	C4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	33.97915	-118.39453	full PC Pwr and Energy for New 8-story, 180-unit, Apartment building. 8-stories(not a highrise) 1-level of subterranean parking. service size is 1600A, 208/120V, 3PH, 4Wire. scope area 27,365SF.***(Customer has a pre written check, plan checker to recount Equipment)***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34512	17041-20000-41309	19331 W BUSINESS CENTER DR Ste # 100	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Closed	02/15/2018 12:00:00 AM	ADDRESS	34.23118	-118.55466	First time tenant/change of use of portion of medical building to pharmacy.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34513	18041-20000-11462	3431 E LOOSMORE ST	90065	1	147A219   374	5454023030	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.09543	-118.22358	Plan check for the installation of a battery back-up system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34514	12041-10000-10922	659 S FLOWER ST	90017	14	129A209    49	5144008009	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM			PC Approved	05/11/2012 12:00:00 AM	ADDRESS	34.04907	-118.2587	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT  T. I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34515	11041-20000-11981	5570 W WASHINGTON BLVD	90016	10	123B177   238	5063022048	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			06/10/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Expired	08/02/2013 12:00:00 AM	ADDRESS	34.03632	-118.36534	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.  Emergency lights are subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34516	10041-20000-18373	1059 N SOMERA ROAD	90077	5	144B145   149	4369030007	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.09091	-118.45873	New 11.96KW Photovoltaic system for single family dwelling.  EPC for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34517	16041-20001-07539	5446 N NEWCASTLE AVE	91316	5	174B129   974	2162009191	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	34.16989	-118.5242	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size 11 kWac and consists of (1) inverter, (48) modules, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34518	13041-10001-21024	2415 E 15TH ST	90021	14	120A217   173	5168010006	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.02106	-118.22952	(((8/29/2014- Changes made to approved set. Relocated Vapor Extraction pump from Building B to Building A)))New Commercial Shell Building 226,955 sq ft.  Full Plan CHeck.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34519	11041-20000-01105	15120 W SUNSET BLVD	90272	11	126B129    21	4411001***		West Los Angeles			YES	2627.02	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	ADDRESS	34.04515	-118.52342	Plan check power and energy for Ralphs markert interior TI. New equipment, panels, and circuits installation to existing muiltiple services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34520	19041-10000-16551	668 S CORONADO ST	90057	1	133-5A201 162	5141007016	PB-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	07/18/2023 12:00:00 AM		Issued	07/18/2023 12:00:00 AM	ADDRESS	34.05985	-118.28169	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES INSTALLING TWO NEW SERVICES 2500A & 1600A 120/208V 3PHASE 4 WIRE.  ALSO, ADDING NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 54203 SQ.FT.B#19010-10000-00654	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34521	18041-10000-42012	611 S LORENA ST	90023	14	123A227   232	5186015032	C2-1-CUGU, RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.03065	-118.19945	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34522	16041-20002-19810	540 S CATALINA ST	90020	10	135B197   936	5502022019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.06411	-118.29524	[[ CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. DELTA 1 CHANGES. REDUCING SYSTEM SIZE TO 47 KW. REDUCTION 3 INVERTERS FROM SB10000 TO SB9000. BACK FEED MAX CONTINUOUS CURRENT REDUCED TO BELOW 200AMPS]]]]]$0 permit fee is due to State Senate Bill SB 1222PV2.  Install 58.48 kW roof mounted PV system.  (2) separate PV systems on building occupying same rooftop.  System 2 of 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34523	15041-10000-29010	1355 N MCCADDEN PL	90028	4	147A185   260	5547033027	RD1.5-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Expired	09/28/2017 12:00:00 AM	ADDRESS	34.09594	-118.33759	PV 1 roof mounted system for a single family home. Scope of work: (1) inverter: 3kw, ( 12) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34524	14041-20000-15744	7235 W HOLLYWOOD BLVD 1-74	90046	4	147B181    95	5548001017	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Apartment			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.10174	-118.34783	PC FOR T-24 ENERGY ONLY.  LOBBY FLOOR LIGHTS WITH SQUARE FOOTAGE 1054.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34525	16041-20000-40337	13025 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.18799	-118.41664	Plan check for power and energy. First time tenant (Petco).  >400A of new load. 14,980sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34526	11041-20000-09484	225 S 26TH ST #25	90049	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	PIN	34.04786183	-118.49061927	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY LIGHTING ) FOR TI OF EXISTING MARKET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34527	16041-20001-15064	5933 N FULTON AVE	91401	2	177B157   937	2343025013	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.17863	-118.42268	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.41 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34528	12041-10000-24923	5520 N BLUEBELL AVE	91607	5	174B161   551	2346028014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.17097	-118.41014	9.36 kw roof mounted PV system for a single family. PV1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34529	18041-20000-35961	15260 W VENTURA BLVD #730	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Issued	09/20/2018 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check for Title 24 Energy only in T.I. remodel office space, new lights, existing circuits. Total area: 1949 sq ft. B#18016-10000-14963	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34530	13041-20000-18135	20521 W VOSE ST	91306	3	183B109   358	2137003011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.1984	-118.5805	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.4KW USING 18 MODULES. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34531	16041-10000-06952	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM			Reviewed by Supervisor	03/17/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	PC FOR A NEW FIRE ALARM SYSTEM TO A 4 STORY BLOOMINGDALES RETAIL STORE. SCOPE INCLUDES 1 FA PANEL, 370 FA DEVICES, AND 2 COMMUNICATION PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34532	11041-10002-20866	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.94386	-118.4047	CHANGES TO PERMITTED SET OF PLANS- RELOCATE,TRMOVE AND ADDED FA DEVICESnew fire alarm system for LAX. 266 devices and 5 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34533	18041-10000-07686	2142 S PALM GROVE AVE	90016	10	123B181   345	5061025008	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2186.00	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.03584	-118.3431	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 10 MODULES (HANWHA Q-CELL Q PEAK-G4.1 305), OPTIMIZERS(SOLAREDGE P320) AND CENTRAL INVERTER(SOLAREDGE SE3000H-US).SYSTEM SIZE IS 3Kac AND 3.05Kdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34534	14041-10000-10281	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	33.97451	-118.42531	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR NONHIGHRISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34535	17041-10000-15168	2322 W 3RD ST	90057	1	135A203   200	5154035016	C2-1	Central	Westlake	MacArthur Park	YES	2088.02	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.06432	-118.27547	Installation of new fire alarm system in existing two story commercial building.  Total system size = 51 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34536	12041-10000-07831	11804 W JOUETT ST	91342	7	216B169    82	2531034029	(T)R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	07/12/2012 12:00:00 AM	ADDRESS	34.28502	-118.3901	New 10.08kw rooftop mounted photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34537	14041-10001-17333	1969 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM			PC Approved	07/31/2014 12:00:00 AM	ADDRESS	34.06159	-118.20463	Changes to approved. Plan check for energy only. Plan check only. Changes include: remove fire alarm notes, removal of bathroom from scope, and removal of fixture D and modification of fixture G to hal borrego pendant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34538	18041-20000-47886	741 S ALVARADO ST	90057	1	132A203   180	5141018014	C2-1	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.05545	-118.27764	Healthcare facility and office TI.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34539	18041-20001-03421	11937 N RICASOLI WAY	91326	12	216B109   332	2701085013	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM			Reviewed by Supervisor	02/06/2018 12:00:00 AM	ADDRESS	34.28986	-118.58501	expeditepv1install roof mounted pv system sized 14.2kw  with (2) tesla powerwalls rated at 5kw each.  plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34540	15041-20000-39313	4530 W BRAZIL ST 1-5	90039	13	165B205    88	5593011034	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.14653	-118.27344	"""0$ permit fees due to senate bill 1222""Install a roof-mounted solar array on a commercial building. Interconnect with a 1600A MSP.System size: 140kW (7 - 20kW inverters). Ungrounded system. Using 700W power optimizers. Each optimizer has 2 pv modules connected to it. (484) 310W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34541	18041-10000-22732	19200 S WESTERN AVE	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	33.85755	-118.30917	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34542	14041-10000-26649	13520 W VAN NUYS BLVD	91331	7	207B157   950	2620014902	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.26189	-118.42756	Energy plan check  for a TI  commercial building including relocation of 400Amp panel, total remodel area is 2225 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34543	12041-10000-30157	234 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/26/2016 12:00:00 AM	ADDRESS	34.05578	-118.25359	Plan check for new 2000 Amp service, new feeders, transforemers, and bus duct to feed distribution panels on each floor. Building E.  Location in methane buffer zone. No installation in hazardous area.  Each dwelling unit future connection under separate permit and shall require plan check. Fire pump on separate application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34544	16041-10000-23175	11260 W MISSISSIPPI AVE 1-17	90025	11	126B153   852	4260001004	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.03984	-118.44175	PC FOR A NEW FIRE ALARM SYSTEM TO FOR A 3-STORY 17-unit apartment with roof deck over 1-level type I-A parking structure. SCOPE INCLUDES 63 FA DEVICES, 1 FA PANEL, AND COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34545	15041-10000-00705	1630 N MAIN ST Bldg 15	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	PIN	34.06623967	-118.22749482	Addition of 12 strings with 14 modules each to an existing PV system belonging to DWP (on top of Building 15). All strings are being combined before connecting to the existing 50 kWac inverter. Permit for original PV system issued under application [10041-10000-04538]. ZERO FEES DUE TO 2012 SENATE BELL NO. 1222(((Installation of an exterior  50 KW Photovoltaic sytem.   The moudules are installed on the roof  of  buidling 15 as shown on the area plan.  The system includes a 50 KW -  3 phase Inverter, 13 strings of  13 modules each, one combiner box suitable for the connection of 24 strings, an AC disconnect switch, and one service disconnect switch.  The system is grid tied, but supplies no other load except the DWP pole mounted transformer.)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34546	14041-10000-32823	16135 W ROSCOE BLVD	91343	12	192B141   406	2673020039	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.22149	-118.48415	New fire alarm system with (1) fire alarm panel and 69 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34547	11041-20000-23316	1549 S POINT VIEW ST	90035	10	129B173   871	5068013011	R1-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2011 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.04892	-118.37095	New 7.92 KW roof mounted PV system for a single family residence.  Applicant is using the standard plan for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34548	15041-10000-01496	9301 N TAMPA AVE #210	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for power and energy. Tenant improvement of existing restaurant to a Red Robin.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34549	18041-20000-39621	5800 W SUNSET BLVD STUDIO 8	90028	13	147A191   143	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.09728	-118.31693	Plan check for Title 24 only in existing building T.I. Total area: 9264 sq ft. B#18016-10000-30749	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34550	15041-10000-10024	303 S HEWITT ST	90013	14	127-5A215  46	5163012007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	11/14/2023 12:00:00 AM	ADDRESS	34.04523	-118.23624	SERVICE UPGRADE TO AN EXISTING MIX USE BUILDING 800AMPS.  REPLAING EXISTING PANELS, RECONNECTING ALL EXISTING BRANCH CIRCUITS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34551	11041-20000-25093	12005 W ALBERS ST	91607	2	174B165   830	2348002041	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			11/23/2011 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.17044	-118.39439	121 unit apartment buildingRequest for Modification to separate Fire Alarm system filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34552	13041-10002-16473	750 S LAMAR ST gate bldg	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Issued	01/27/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	Change to approved set by modifying the lighting floor plan on most of the buildings in the master set, new panels also being added. All changes in this application shall be approved along with application number 13041-10001-16473. NOTE, ALL CHANGES UNDER CLOUDED AREA ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34553	11041-20000-19544	11766 W WILSHIRE BLVD 8th fl.	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.04804	-118.46227	8th floor office t.i.Energy onlyFire/ Life safety by others  11041-10000-16868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34554	16041-10001-04334	12951 W EUSTACE ST	91331	7	213B161    62	2527006003	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.28427	-118.41488	[PC only] PV1 rooftop solar installation(17) KU2656ZPA (1) PVI-3.6 OUTDPermit under 16041-90000-04334	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34555	18041-20002-43657	20308 W BALTAR ST	91306	3	189B113   352	2107009002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2019 12:00:00 AM			Corrections Issued	08/12/2019 12:00:00 AM	ADDRESS	34.21645	-118.57575	Revision to approved plans.  Approval for clouded and initialed revisions only.  (((PV1.  Install 7.6 kW roof mounted grid tied PV system.  (20) modules with 7.6 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34556	14041-20000-17284	12312 W OLYMPIC BLVD	90064	11	123B149   659	4259025008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.03166	-118.45665	TENANT IMPROVEMENT FOR AN EXISTING COMMERCIAL TWO STORY BUILDING. ADDING NEW LOADS PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34557	12041-10000-01872	435 S CURSON AVE WEST	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Apartment			01/25/2012 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.06738	-118.35657	Tower #48. New 4000A service, switchboards, panels, and circuits for an existing 153 unit apartment building in a methane zone - no existing membrane.  The dwelling unit  new panels and new circuits shall be installed under separate permits. Park La Brea	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34558	15041-20000-20598	17370 W CHASE ST	91325	12	192B129   226	2787019005	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.22314	-118.51243	Plan check for a PV1 roof-mounted PV system. System size is 4.3 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34559	16041-20000-10546	1420 N COIL AVE	90744	15	036B213    16	7426029007	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	33.79347	-118.24241	PLANCHECK FOR T24 ENERGY. TENANT IMROVEMENT. REPLACE METAL HALIDES WITH LEDS INSIDE WAREHOUSE COOLER. 117, 476 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34560	17041-20000-02352	11365 W VENTURA BLVD	91604	2	162B173   448	2366036025	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.14027	-118.37796	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of a new generator, installation of a UPS and other loads, and refeeding existing equipment after reconfiguring the single line diagram.Note: Building permit has been issued under 16016-10000-06448/11574	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34561	12041-20000-12358	15900 W OLDEN ST	91342	7	225B141  1506	2604002064	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.3118	-118.47749	New 2 story office building.  Supplied by existing 1200 ampere service on the site.   Plan check for energy, power, and emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34562	17041-10000-09227	661 W REDONDO BEACH BLVD STE 739	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Issued	04/12/2017 12:00:00 AM	ADDRESS	33.89279	-118.28725	Plan check for Title 24 only in existing space T.I. Total area: 4,842 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34563	15041-10000-14933	9701 W MUSTANG WAY	91040	7	204B181    64	2549025036	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Expired	08/04/2016 12:00:00 AM	ADDRESS	34.25899	-118.34319	PV1 INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (31) MODULES: KYOCERA  KU2606XPA(2) INVERTER: PVI-3.0-PUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34564	18041-10000-08398	10900 W WILSHIRE BLVD 7TH FLR	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	TENANT IMPROVEMENT FOR (E) OFFICE (13,292 SF) plan check is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34565	15041-10000-02509	1011 S PARK VIEW ST	90006	1	130-5A201  70	5136003003	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Apartment			01/27/2015 12:00:00 AM			PC Info Complete	04/11/2016 12:00:00 AM	ADDRESS	34.05306	-118.28326	Plan check for power and title 24.  Total area = 55,889 sq. ft.New 108 unit apartment building with 3 kA service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34566	19041-10000-14042	2423 E 1ST ST	90033	14	127-5A223 177	5180002013	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.04348	-118.20886	NEW FIRE ALARM SYSTEM FOR 61 UNITS APARTMENT BUILDING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34567	19041-20000-33562	7930 W DAY ST	91040	7	204B193   970	2559022007	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.25455	-118.30592	PV1. INSTALL 13.84 KW DC SOLAR SYSTEM WITH (38) MODULES AND OPTIMIZERS (P400) AND (1) INVERTER (SE11400H-US) SOLAR EDGE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34568	18041-10000-36610	10116 S MAIN ST	90003	8	091-5A205 297	6063008014	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Issued	11/13/2018 12:00:00 AM	ADDRESS	33.94411	-118.2737	Energy plan check for a CHANGE OF USE FROM (E) METAL SHOP TO RETAIL/OFFICE. Scope includes new 400-Amp service, equipment, and lighting with a total area of 4269-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34569	11041-20000-13711	1740 W COLORADO BLVD	90041	14	162A225   117	5689003003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.13918	-118.2051	CHANGE OF USE OF (E) 24' X 30' RETAIL STORE TO PIZZA & HOTDOG PARLOR; EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34570	19041-30000-01221	10240 N COMMERCE AVE	91042	7	204B197   886	2565015132	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Apartment			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	07/17/2020 12:00:00 AM	ADDRESS	34.25531	-118.28848	Plan check for a fire alarm system for a 36-unit apartment building. Fire alarm system consists of (1) FACP and (106) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34571	13041-20001-26150	11455 N LAUREL CANYON BLVD	91340	7	213B149   511	2613027020	(T)(Q)C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Approved	02/09/2015 12:00:00 AM	ADDRESS	34.27805	-118.4529	PC FOR T24 ENERGY ONLY. THIS IS RECHECK FOR SITE LIGHTING. CHANGES TO APPROVED SET NOW SHOWS LED FIXTURES. BUDGET REMAINS THE SAME. CALCS HAVE BEEN UPDATED AND SITE PLAN HAS BEEN UPDATED AS SHOWN. THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34572	12041-20000-14172	7932 N MAESTRO AVE	91304	12	189B093   319	2020017065	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2012 12:00:00 AM			Reviewed by Supervisor	08/09/2012 12:00:00 AM	ADDRESS	34.21467	-118.6394	New roof mounted PV system (17KW).  Upgrade main panel to 400A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34573	13041-10000-09463	3321 S KEYSTONE AVE	90034	5	120B161   278	4314020004	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Expired	05/07/2015 12:00:00 AM	ADDRESS	34.02758	-118.4126	PV1 3 STORY APARTMENT DWELLING. TOTAL SYSTEM SIZE: 1.96 KW. STANDARD PLAN 12 MODULES AND 1 INVERTER. [INVERTER: POWERONE AURORA PV1-3.8-1] [PV MODULE: TRINA SOLAR TSM-245PC05/PA05.18].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34574	18041-10000-04965	3434 E WHITTIER BLVD	90023	14	121-5A227 163	5188017006	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Issued	10/11/2018 12:00:00 AM	ADDRESS	34.02719	-118.19999	PC FOR A NEW 400A 120/240v 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD FOR AN EXISTING MEDICAL FACILITY. REFEEDING EXISTING PANELS TO NEW SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34575	19041-20000-49140	9324 N ELBEN AVE	91352	7	198B185    41	2545025010	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.2382	-118.33548	PV1. INSTALL 11.55 KW DC / 10.653 KW AC CEC PV SYSTEM WITH (30) MODULES AND 7.6 KW RATED INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34576	17041-10000-23288	1539 N RANDALL CT	90065	1	148-5A219  88	5464030032	R1-1, R1-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.1013	-118.22734	PC FOR BATTERY STORAGE SYSTEM AND LOAD CENTER TO EXISTING SOLAR.BATTERY SYSTEM SIZE 5.8KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34577	13041-10001-34143	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM			PC Info Complete	02/27/2015 12:00:00 AM	ADDRESS	34.06188	-118.30486	Changes to an approved set of plans. Changes include the change of copper feeders to aluminum feeders. A copy of the original set of plans will be brought at a later date, as approved for submittal by M.Z. 1/30/2015(((Partial renovation of the 1929 Historic School Building and complete renovation of the 1962 School Building.  2 story school and 1 story admin office.  Plan check for power and energy.  45,400 sq ft..  Work under this permit shall not alter or demolish historic features.CRA:)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34578	16041-10000-13960	1000 W 8TH ST	90017	14	129A207    90	5144023038	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.04866	-118.26309	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR A MIXED USE BLD (APPARTMENT / RETAIL/ PARKING GARAGE ) CORE AND SHELL ONLY (R3). SCOPE INCLUDES 3014 FA DEVICES, ONE  MAIN FA PANEL, (11) SUB FA PANELS ,  (1) COMMUNICATON PANE AND (64) CONTROL PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34579	16041-10000-40425	12610 W RAYMER ST	91605	2	186B161   571	2324003021	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.2033	-118.4078	Full plan check for a  new 3 story commercial self storage building with 600 amp service.  Total area = 25,946 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34580	17041-20001-32901	18163 W SHERMAN WAY	91335	3	186B125   894	2119028015	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	34.20135	-118.5295	Revisions to approved set.  Change from 3 phase panels to single phase.  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to laundry mat/tenant improvement. Work includes a new 600-amp service and a total lighting area of 4,194 sq. ft.Note: Building application has been generated under 17016-20000-24644)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34581	17041-20000-00600	464-468 S ROBERTSON BLVD	90048	5	135B169    12	4334003041	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.07035	-118.38361	Plan check for Title 24 only. Project site is an existing commercial retail space. Project scope is a tenant improvement. Total lighting area = 2,200 sq. ft.Note: Building permit has been pulled under 16016-30000-28710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34582	13041-10002-30063	1203 N LAS PALMAS AVE	90038	4	144B185  1343	5532004036	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.09278	-118.33649	Expedited RSES plan check per applicant request.((((PV1, Install 1.59 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US. 6 modules Suniva OPT265-60-4-1B0.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34583	13041-20000-34425	7331 N FIGUEROA ST	90041	14	162A229   274	5690023045	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.13715	-118.18819	replace damaged 800 amps swichgear with same size	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34584	18041-10000-16842	11791 W SHERMAN WAY	91605	2	186B169   912	2317019030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.20138	-118.39022	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34585	12041-10000-28959	11017 W VENTURA BLVD	91604	2	162B173   458	2366023013	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.01	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Closed	05/03/2013 12:00:00 AM	ADDRESS	34.14084	-118.37075	Installing circuits to supply new beauty saloon.T.I.  Existing hair salon occupying space # 216.  Modification is being done to the interior lighting.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34586	19041-20000-09559	8479 N MOORCROFT AVE	91304	12	192B101   251	2004019009	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.2243	-118.6123	INSTALLATION OF A 5KW TESLA POWERWALL TO A EXISTING SFD WITH A EXISTING PV SYSTEM AND A 125A SUBPANEL.  175A MAIN BREAKER DERATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34587	16041-20001-31279	10231 W MCBROOM ST	91040	7	207B181   309	2543007022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	34.26483	-118.35253	EXPEDITED PER APPLICANTS REQUEST.BATTERY STORAGE SYSTEM  + PV1 ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.16 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34588	12041-10000-04976	6300 W HOLLYWOOD BLVD	90028	13	148-5A187 367	5546009***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.1014	-118.32687	TI in the corridoor & storage areas of a restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34589	10041-20000-02849	15821 W VENTURA BLVD 110	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	02/19/2010 12:00:00 AM		Permit Finaled	04/19/2010 12:00:00 AM	ADDRESS	34.15584	-118.47812	T.I IN OFFICE SUITE 110. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34590	17041-10000-03433	9200 N OWENSMOUTH AVE	91311	12	198B105   124	2746011007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.23764	-118.60177	PC for outdoor title 24. Removign HID fixtures and repalcing them with new LED ones. Area: 71,100 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34591	18041-20001-48449	20634 W YORKSBORO LANE	91364	3	168A111    58	2174005027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.15543	-118.58305	Expedite per applicant request Plan check for PV roof mounted system, system size: 18.82 kW DC, 19.99kW AC with 53 PV Moduels and 53 microinverters connected to 400A existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34592	13041-10001-36140	13271 N HERRICK AVE	91342	7	225B145   280	2501009006	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.31209	-118.46223	Expedited RSES plan check per applicant request.{{PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 200A MAIN IN A 1-STORY HOME. non-standard plan. SYSTEM SIZE IS 3.75 kW DC, & transformerless, with power  optimizers  (15) Trina solar #TSM-250PA05.18(1) Solaredge #SE3800A-US.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34593	12041-10003-24908	1111 W SUNSET BLVD	90012	1	136-5A211 440	5406020003	C2-2D	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			11/06/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.06583	-118.24918	Addition of a feeder,75KVA XFMR, 225A PANELBOARD  TO SUPPLY 7 EA EV CHARGING CIRCUITSRenovation of an existing 103 units appartment Bldg. EPC is for power & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34594	19041-10000-16614	1 S LMU DR BUILDING A	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	11/17/2020 12:00:00 AM	ADDRESS	33.96577	-118.42406	Full plan check Power and energy for New construction of 4-story Type V-A  dormitory with partial basement.   It is comprised of communal amenity spaces, one- and two-bed dorm rooms, gang bathrooms, faculty apartments, and housing offices.  (Building A). Feeder to this building is 4.6KV,600A. 4wire,3PH. Service derived from building B. scope of work area 109,018SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34595	14041-20000-08165	20051 W VENTURA BLVD UNIT E	91367	3	174B113   447	2166001031	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	PIN	34.17141843	-118.57066189	Install general/emergency lighting in the Access Veterinary Services.  Plan change energy only.Note:  Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34596	16041-20001-23177	7900 N BALBOA BLVD Bldg Alpha	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.21347	-118.50092	8.28.2017 - Plan check for modifications to approved set. Upgrade service from 200A to 600A. Panels A2-A7 are no longer being fed from their own meters, they are being fed from a tap off of a 125A feeder. Changes clouded.======Plan check for power, hazardous location requirements, and energy. Project site is a row of (9) new portable hangers referred to as the Alpha Building. Total lighting area = 17,480 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34597	10041-10000-00095	7320 N WOODLAKE AVE 210	91307	3	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM	01/07/2010 12:00:00 AM		Permit Finaled	02/10/2010 12:00:00 AM	ADDRESS	34.20263	-118.63189	TI work in doctors office. Moving two light fixtures and putting back after doing t bar or lowering the ceiling. this plan check is only Title 24 energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34598	12041-10000-29274	21540-21544 W NORDHOFF ST	91311	3	195B105     8	2779018033	[Q]MR2-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.23525	-118.60037	FULL POWER AND ENERGY PC. NEW LOADING DOCK FOR REFRIGERATION TRUCKS. NEW SERVICE + 1600A MAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34599	10041-20000-25029	445 S FIGUEROA ST 1st. floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM			PC Info Complete	12/16/2010 12:00:00 AM	ADDRESS	34.05295	-118.25675	T.I. to partial of an existing high rise building of 1st floor (Union Bank).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34600	14041-10000-12451	12921 W EVANSTON ST	90049	11	129B137   297	4406023007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.05093	-118.48958	PV1 7.28KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(26)modules: {SUNPREME GxB 280W modules}] [optimizer????????????????]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34601	12041-20000-27698	22401 W COLLINS ST	91367	3	174B101   144	2040038001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.17467	-118.61499	New rooftop mounted photovoltaic system for an existing single family residence.  11.1kw.  System is UNGROUNDED.  The main service disconnect is reduced from 200 ampere to 175 amperes,  to comply with 690.64.(B)(2).  A monitoring system is installed at the murray subpanel, and a ground rod is driven for the murray subpanel as required by DWP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34602	17041-20000-07260	14117 W HUBBARD ST unit 1	91342	7	219B153   199	2508027029	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.29849	-118.44081	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square fotage 742.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34603	16041-30001-18527	4521 S CIMARRON ST	90062	8	111B189   531	5015025032	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.00208	-118.31617	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) panels. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34604	16041-10001-42962	433 W LACONIA BLVD	90061	15	081B201   129	6132020047	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	ADDRESS	33.91987	-118.28228	expedite per applicant request.(((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.6KWdc / 10.0KWac.(40)MODULES-JKM265P(2)INVERTTERS-SOLIS-5K-2G-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34605	17041-10000-28669	19322 W ROSCOE BLVD	91324	3	192B117   784	2105019018	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.22024	-118.55422	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY. TOTAL SQ FT 16321.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34606	14041-10000-25726	3255 W WILSHIRE BLVD # 120	90010	10	135B197  1185	5502026020	C2-2, C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.06195	-118.29324	CHANGE OF USE TO MEDICAL OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34607	13041-10000-18731	18349 W CHATSWORTH ST	91326	12	207B125   273	2715008019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.26468	-118.53371	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A NON STANDARD PLAN. SYSTEM SIZE IS 5.1465 KW. USING 21 MODULES AND 1 TRANSFORMERLESS INVERTER. [INVERTER: AURORA PVI-4.2-OUTD-S-US-Z |||| MODULES: TRINA SOLAR # TSM-245PC05/PA05.18]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34608	17041-10000-20283	1361 E NEWTON ST	90021	14	121-5A213 125	5130010024	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.027	-118.24547	"Title 24 plan chek.  Repair office and manufacturing building from fire damage.  New 400 amp service with two subpanels feeding lighting, receptacles, and HVAC.  Total area = 4,393 sq. ft.       Building permit #17016-10000-04784CEIS138787""COMPLY WITH DEPARTMENT ORDER effective date02/19/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34609	12041-10000-05708	628 S HILL ST	90014	14	129A211   170	5144003024	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.0467	-118.25345	UPGRADE SERVICE TO 600A AND RECONNECT FEEDERS TO EXISTING PANEL (  628 1/2 S. HILL ) AND TO PANEL ( 630 S. HILL ) AND ADD NEW FEEDERS  FOR 628 S. HILL. NEW PANELS AND CKTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34610	19041-10000-20508	20300 W VENTURA BLVD	91364	3	174B113   554	2166035029	(Q)CR-1VLD, (Q)P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.16912	-118.57531	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34611	16041-20001-34773	9811 N FULLBRIGHT AVE	91311	12	201B113   360	2748009019	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM	ADDRESS	34.24842	-118.57813	RSES expedited plan check fee per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34612	10041-10000-17653	1209 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.05138	-118.22643	Solar voltaic system installed on the roof of the building.  Consists of  8 modules,  8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34613	19041-20000-41797	10817 W PICARDY ST MS1	91602	2	168B177   842	2421030001	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	10/03/2020 12:00:00 AM	ADDRESS	34.15424	-118.36641	New 600A 240/120V 1ph-3w service supplying (6) SFDs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34614	16041-10000-42767	17316 W TRAMONTO DR 1-4-Bldg 7	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	11/25/2020 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building 4 story 4 units (Type B) .  With 1 service 2,500A feeding all 9 buildings. Performance method is being use for Title 24. Total area: 16,235 sq ft. (building 7 distribution board = 400A) Note: This is 9 buildings submit  in 1 plan. 7 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34615	17041-20001-10682	1018 S DODSON AVE	90732	15	015B193   927	7560022004	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM			PC Approved	04/08/2017 12:00:00 AM	ADDRESS	33.73443	-118.31173	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (36) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34616	14041-10000-35712	14823 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.17768	-118.45525	Power plan check for service upgrade from 1200 Amp 240v 3Phase 3 wires to 1200-Amp 277/480V 3phase 4 wires. with new panel and no connected load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34617	14041-20000-12262	5044 N BAKMAN AVE	91601	2	171B173  1066	2353013019	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			05/08/2014 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.16205	-118.37722	PLANCHECK FOR POWER AND ENERGY . 5 STORY 46 UNIT APT WITH SUBTERRANIAN PKG2 PLAN CHECK TIME ESXTENSIONS FILED. 5/12/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34618	16041-20001-14712	20127 W VIA CELLINI	91326	12	219B113    27	2701039016	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.29409	-118.5716	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 300A MSP.System size: 7.6kW. Ungrounded system. (34) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34619	16041-10000-32741	557 S SPRING ST	90013	14	129A211   274	5149035014	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Issued	11/18/2016 12:00:00 AM	ADDRESS	34.0463	-118.25087	Plan check for Title 24 only in existing space high-rise building on 1st floor. Total area: 703  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34620	10041-20000-07743	7651 N DENSMORE AVE	91406	6	186B141    24	2206010008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			PC Approved	04/27/2010 12:00:00 AM	ADDRESS	34.21003	-118.47725	OFFICE TIEnergy. This plan check is Revision to approved plan of 10041-20000-06404 chaning lighting fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34621	10041-20000-09912	13050 W SAN VICENTE BLVD	90049	11	129B137   501	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM			PC Approved	05/25/2010 12:00:00 AM	ADDRESS	34.0483	-118.49125	Installing light in rehabilitation center. Energy only.  There is existing permit in application # 10041-30000-08610.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34622	15041-10000-39033	1221 W 3RD ST	90026	1	132A209    74	5152013019	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Apartment			11/18/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	PIN	34.05725872	-118.25842757	$0 permit fee due to senate bill 1222 from 2012PV2 ROOF MOUNTED 284.7 KWAC TRANSFORMERLESS 1000VDC 3P 480V INVERTER OUTPUT. 1050 MODULES AND 13 INVERTERS. interconnect to existing service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34623	18041-30000-48297	13160 W MINDANAO WAY Suite 202	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	03/04/2022 12:00:00 AM	ADDRESS	33.98501	-118.43726	Plan check for power and energy. Project site is an tenant suite in an existing commercial building. Project scope is a change of use from office to medical office. Total lighting area = 1,838 sq. ft.Note: Building application has been generated under 18016-30000-40639.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34624	16041-10000-11221	214 E 69TH ST	90003	9	102B205   424	6011005019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Expired	05/02/2018 12:00:00 AM	ADDRESS	33.97686	-118.27121	PV1, INSTALL 3710W DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: HANWIA Q-CELLS Q.PRO-G4 265(1) INVERTER: SOLAREDGE SE3000 240V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34625	13041-10000-04076	1210 S CORNING ST	90035	5	132B173  1021	4332028003	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			02/15/2013 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.05535	-118.37723	A PROPOSED IRR 40' X 107'  2-STORY 7 UNIT APT BUILDING WITH MEZZNINE LEVEL AT 2ND FLOOR OVER ONE LEVEL BASEMENT GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34626	14041-20000-16530	9176 N ONEIDA AVE	91352	6	198B165   288	2629014098	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.23639	-118.40088	4.9KW PV1 roof-mounted system with (22) Tinasolar modules and Enphase M215 microinverters interconnecting through a sub panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34627	15041-10000-24441	5000 S MAIN ST	90011	9	111A205   300	5109004053	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Apartment			07/30/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	PIN	33.99720157	-118.27357014	PC FOR FIRE ALARM SYSTEM. (4) FLOOR AND ROOF RESIDENTIAL BLDG. (1) FIRE ALARM CONTROL PANEL (1) ANUNCIATOR, COMMUNICATION PANEL (10) SIGNAL PANEL EXPANDER, CONTROL PANE.(188) FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34628	15041-10000-14025	7836 W JAYSEEL ST	91040	7	208-5A195 249	2556011039	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.26533	-118.30399	PV1, Install 4.480 kW DC roof-mounted grid-tied solar array, interconnect with service panel. (16)modules: solarworld Plus SW 280 mono black(1) Inverter: Power-one PVI-3.6-OUTD-S-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34629	11041-10000-14338	442 S LAKE ST 1-15	90057	1	133-5A203  43	5154031023	R4-2	Central	Westlake			2088.00	Electrical	Electrical	Public Safety Only			07/11/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.06177	-118.27473	NEW FIRE WARNING SYSTEM FOR 15 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34630	19041-10001-32003	9201 N OWENSMOUTH AVE	91311	12	198B105   144	2746012037	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.23757	-118.60203	EXPEDITE PER APPLICANT REQUESTPV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 443 MODULES (SPR P17 330W), 222 OPTIMIZERS (P850 ), 2 INVERTERS ( SE 66.6K) SYSTEM SIZE IS 133.2KWac AND 146.2KWdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34631	15041-20000-25950	16113 W RAYEN ST	91343	12	195B141   307	2672003028	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Expired	09/05/2017 12:00:00 AM	ADDRESS	34.23212	-118.48329	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34632	15041-10003-18741	12415 N SAN FERNANDO ROAD	91342	7	219B149   666	2611007035	(T)(Q)C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Apartment			08/16/2016 12:00:00 AM			PC Info Complete	10/13/2016 12:00:00 AM	ADDRESS	34.29585	-118.45528	Changes to approved set.  All changes clouded and marked with delta 3.  Change to rating, feeder, and protection for both elevators.  Changes to available fault current values.  Updated load calculations.  Changes to AIC ratings.  Changes to all 101 feeders supplying unit panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34633	18041-10000-12498	2361 W 31ST ST	90018	10	120B189   456	5052005003	R1-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.0266	-118.31977	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE IS 6KVA CONSISTING OF 1 CENTRAL INVERTER (SE6000A-US) WITH 24 PANELS WITH (P320 POWER OPTIMIZERS)SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34634	13041-10000-35109	3650 W MARTIN LUTHER KING, JR BLVD # 162	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	PLANCHECK FOR T24 ENERGY ONLY.  INTERIOR T.I. TENANT SPACE # 162 IN BALDWIN HILLS CRENSHAW PLAZA. LOCATED AT 1ST FLOOR. 2883 SQFT. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34635	19041-10000-09658	417 E 15TH ST	90015	14	123A209    68	5133022008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.03232	-118.25826	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34636	18041-20000-38991	6058 N SAUSALITO AVE	91367	3	177B101   117	2039027040	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.18074	-118.61602	Plan check for a PV1 roof-mounted PV system. System size is 14.625 kWdc/13.45 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (45) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34637	14041-10000-16990	13031 W JEFFERSON BLVD #100	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR "" BUILDING 9"". CHANGE OF OCCUPANCY TO KITCHEN. NOT A FIRST TIME TENANT AND NEWLY CONNECTED LOAD <400 AMPS PER APPLICANT. 3047 SQFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34638	19041-10000-34122	5835 S BRENTWOOD ST	90003	9	108B201  1422	6005008030	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	33.98865	-118.2773	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34639	19041-20000-04276	3364 S MOORE ST	90066	11	114B149   386	4247013015	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.0095	-118.44763	pv1install roof mounted pv system sized 11.4KW interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34640	15041-10002-14231	600 WORLD WAY Terminal 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			No Progress	08/28/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	Plan check for SLD details per inspection request.  First tenant move-in on 1000A 120/208 distribution board serving commercial retail/restaurant spaces.  (((8/25/15: Supplemental, changes on light fixtures(T-24 FOR TWO KITCHEN SPACES IN LAX, TOTAL SQ. FT. 1190))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34641	19041-20000-23617	1338-1344 N SYCAMORE AVE	90028	4	147B181  1226	5548023114	RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Issued	07/03/2019 12:00:00 AM	ADDRESS	34.09542	-118.34231	800A 240/120V 1ph-3w service for small lot subdivision with (10) SFDs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34642	19041-10000-40141	118 N ORLANDO AVE Unit #1-6	90048	5	138B173   552	5511011006	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			10/03/2019 12:00:00 AM	06/10/2021 12:00:00 AM		Issued	06/10/2021 12:00:00 AM	ADDRESS	34.07512	-118.37301	Plan Check completed under supplemental EPLAN  permit # 19041-10001-40141.FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW 4 STORY 6 UNIT APARTMENT, SERVICE SIZE IS 600 A(1P 3W) THAT FEEDS  A 600A METERBANK THAT SUBFEEDS THE DWELLING UNIT PANELS AND HOUSE PANELS. TOTAL AFFECTED AREA IS 4209 SQFT.B#19010-20000-01046	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34643	16041-20000-03765	1999 S AVENUE OF THE STARS 2ND LEVEL	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 2ND LEVEL OFFICES.HIGH RISE. 3629 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34644	12041-20001-24451	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.30237	-118.46212	"Modification to previously approved plans, changing equipment ratings and adding additional load.  PLAN CHECK ONLY FOR ""DELTA 4"" CHANGES         <<<< electrical and lighting, for a new 3000A service for industrial building (Plant 1).  Install new switchgear, panels, equipment and lighting.  Plan check for power and energy.  Plan check to charge fees for any new equipment installed.  Review original set of plans for prior approval.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34645	15041-20000-32503	888 S OLIVE ST 1st Floor	90014	14	127-5A209 127	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	11/06/2023 12:00:00 AM	ADDRESS	34.04383	-118.25785	Plan check for power and eneregy 1st time tenant for fitness center in high rise residential building on 1st floor. Total area: 4,176 sqft.Note: Building application filed under 15016-40000-21187	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34646	14041-20004-24308	13854 W MAGNOLIA BLVD	91423	4	171B153   466	2269006002	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.16466	-118.43527	Modification to approved modified set. No longer derating main breaker to 175A with a 200A MSP. Instead upgrading MSP from 200A to 225A and keeping a 200A main breaker. Also changing/raising solar OCPD in MSP to 70A.$0 plan check fee is due to Senate Bill SB-1222.[[[Modification to approved set.  Change of feeder details from load center to MSP.   (((PV1.  Install 14.0 kW roof-mounted, utility-interactive PV system.  Microinverters.)))]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34647	18041-10000-31312	11111 W SANTA MONICA BLVD 2ND FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK FOR T24 ONLY, RESTROOM & CORRIDOR REMODEL ON THE 2ND FLOOR OF AN OFFICE BUILDING. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-22286	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34648	14041-10001-14332	1307 S OCEAN FRONT WALK	90291	11	108A143   412	4226006003	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM			PC Info Complete	11/20/2014 12:00:00 AM	ADDRESS	33.98828	-118.47474	((11/5/2014 - Sup. application for changes to approved set at request of inspector.  Plan check for power and title 24.  Changes reflect as built field conditions.  Major changes to single line diagram including new 600A service and 4 new panelboards.  Total area = 1,713 sq. ft.))Change of use to take out tenant imporovement of existing two story building.Total area = 1713 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34649	19041-10000-15825	1933 S BROADWAY	90007	9	123A207     2	5126031010	[T][Q]C2-2-O-SN	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.03006	-118.26696	Full Plan check for power and energy for New Digital signs. Scope of work includes a new 600A , 4.16KV, 3ph, 4W Switchboard, 3 unit substation, and panelboards. Total affected area is 13,185 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34650	12041-10001-30627	8156 W MELROSE AVE	90048	5	141B173   461	5528011004	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM			PC Approved	04/29/2013 12:00:00 AM	PIN	34.08346465	-118.36725718	"Changes to approved lighting plan.  Removal of incandescent chandelier fixtures, replaced with 2"" flourescent fixtures.  Additional luminaires of other fixture types as well.Original Work Description: TENANT IMPROVEMENT  AT AN IMPROV/RESTAURANTPLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34651	17041-20000-00749	1700 W SUNSET BLVD MEZZ	90026	13	139-5A209 152	5404017020	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.0771	-118.25863	Plan check for energy only. TI to 4,465sqft office space. New lighting (incl. emergency).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34652	12041-20000-11922	2970 W OLYMPIC BLVD #304	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			Plans on Hold	05/25/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	nedical office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34653	14041-20000-35059	1215 W 58TH PL	90044	9	108B197  1531	6003002016	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	33.98846	-118.29644	PV1 Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). Ungrounded system., 24  327W pv modules across 4 strings (6+6+6+6).Note: solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34654	17041-20000-05563	7236 N EASTHAVEN LANE	91307	12	186B089   712	2027022026	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Refund in Progress	10/20/2017 12:00:00 AM	ADDRESS	34.20264	-118.64782	PV1.  Install 11.76 kW roof mounted grid tied PV system.  (42) modules with 3.8 kW and 5.2 kW rated string inverters.  Derate of main service disconnect.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34655	18041-20000-04655	339 N FAIRFAX AVE	90036	5	138B177   197	5527036016	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.07732	-118.3616	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,947 sq. ft.Note: Building application has been generated under 17016-10000-35484	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34656	14041-10000-15405	10800 W PICO BLVD #358	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.04054	-118.4272	PC FOR ENERGY ONLY.Commercial T.I. project of an existing lease space. TOTAL AREA 4492 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34657	18041-20000-19050	5263 W ADAMS BLVD	90016	10	123B177   910	5043003050	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.03266	-118.35751	Fire alarm system for 3-story mixed use 14 unit apartment building.  (42) signaling and notification devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34658	13041-10001-36230	11966 W BURTON ST	91605	6	192B165   615	2310003009	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	03/05/2014 12:00:00 AM	ADDRESS	34.2206	-118.394	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY , INTERCONNECT TO (E) 200A MAIN IN A 1-STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE IS 3.25 kW DC. (13)POWER OPTIMIZER:Solaredge Op250-LV-MC4SM-2NA-Z   (13)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3000A-US}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34659	14041-20001-10130	23433 W ARMINTA ST	91304	12	189B093   446	2020004036	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.21338	-118.63771	EXPEDITE PER CUSTOMER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34660	17041-10000-32906	10250 W SANTA MONICA BLVD #2310	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for power and energy for fisrt time tenant ""Vans"" Ste # 2310 in Westfield Century City."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34661	18041-10000-41575	380 WORLD WAY TBiT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for a retail TI. Scope includes new lighting and equiqment with a total area of 1,876-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34662	16041-20000-31723	3860 S CRENSHAW BLVD	90008	10	117B185   775	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	34.01577	-118.33473	TI TO AN EXISTING BUILDING.  BATHROOM REMODEL, ADDING NEW LIGHITING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34663	16041-10001-16503	225 N VERMONT AVE	90004	13	138B197   568	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.07529	-118.29188	PC for revision for approved set to reflect changes on the field per inspection. Scope includes addtion of 2 strobes and 5 duct detectors.**************+update contractor info	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34664	12041-20000-02323	11239 W VENTURA BLVD	91604	2	162B173   294	2366035036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.01	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.14181	-118.37523	renovation of existing dressing room in MarshallsEnergy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34665	18041-20000-11635	9430 N BRANDON CT	91325	12	198B129    59	2766021028	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Expired	05/05/2024 12:00:00 AM	ADDRESS	34.24235	-118.51889	pv1install roof mounted pv system sized 12.9kw AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34666	13041-10000-28400	13116 N KISMET AVE	91342	7	222B161    67	2512028051	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.30854	-118.418	PV1 4.32KWAC. 240V. positive GND. STD. 2story. Roofmount. [(20) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(20)modules: {Suniva Optimus OPT265-60-4-100}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34667	11041-10001-13525	1000-1012 E LAKE ST Bldg 5-1	90291	11	111B145   574	4243003040	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			10/03/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.00142	-118.46071	New 2 story 11 unit apartment building.  Full plan check.(((((  10-3-14  mz  installation of 5  20 amps E.V)))))))))))))))Note to plan checker:  At the time application was generated plans were not provided.  Fees were generated based on what the engineer indicated in the plan check application form.  Verify fees and quantity of units during the plan check process.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34668	15041-20000-09416	4314 N ALCOVE AVE	91604	2	165B161   609	2375008017	RD1.5-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.1487	-118.4123	PV1. ROOFMOUNTED SOLAR SYSTEM. 4KW SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34669	14041-20001-03174	3414 N THE PASEO	90065	1	153A217   436	5460009007	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.11169	-118.23281	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 5.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34670	13041-20000-15806	800 W WORLD WAY Term 8-Spc #8e	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	PIN	33.94153561	-118.3984113	Install new wall sign inside LAX Airport Terminal 8 at Carls Jr.  Plan check only for T-24 PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34671	16041-20000-23924	1441 S VETERAN AVE 1-111	90024	5	129B153   139	4324013032	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.05268	-118.44373	PV2.  Install 155 kW DC roof-mounted PV system.  (456) modules with (4) 24kW and (1) 20kW transformerless central invertersNote: Fee $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34672	18041-20000-38841	16945 W CHATSWORTH ST pv1	91344	12	207B133   458	2683023003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.26493	-118.50156	pv1install roof mounted pv system sized 5KW AC interconnected with msp.  this is plan check only. permit fees paid under application number 18041-90000-34737.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34673	18041-10000-46202	1020 N SWARTHMORE AVE	90272	11	129B125   863	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.04769	-118.52531	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A CORE AND SHELL RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1062 SQ. FT. B#18016-10000-38245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34674	15041-10000-10551	11922 S VERMONT AVE	90044	15	084B197   351	6088020013	C2-1L	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	33.92425	-118.29139	Replacement of two incandolecent lights with florescent fixtures  in storage or prep room of Ralphs store, total area 290 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34675	18041-30000-15580	350 S GRAND AVE Suite 3410	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only. Project site is the 34th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 3,255 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34676	14041-20000-20814	7401 N OAKDALE AVE	91306	3	186B113   597	2115006030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.20494	-118.56722	PV1Central/string inverter standard plan.Install roof-mounted solar array on SFD. System size: 6kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(24) SolarEdge P300 power optimizers(24) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34677	10041-10000-05276	13741-13745 W VICTORY BLVD	91401	2	180B153  1020	2238013043	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.00	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	07/23/2010 12:00:00 AM	ADDRESS	34.18683	-118.43274	Plan check for power.  Replace existing 400A 1-phase/100A 3-phase overhead to 600A 120/240 1-phase with (3) 200A meters. In addition,  new feeders, and new panel PB with new breakers for existing loads. No new load  added to system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34678	17041-20000-32230	1800 CENTURY PARK EAST 11 th flr	90067										Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM			PC Approved	09/08/2017 12:00:00 AM				ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34679	19041-20000-38496	7607 S MAIN ST	90003	9	099B201   134	6031013012	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	06/18/2021 12:00:00 AM	ADDRESS	33.97057	-118.27418	PV2. INSTALL 1.525 KW DC/1.2 KW AC SYSTEM PV WITH (5) PV MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34680	11041-20000-08193	6100 W WILSHIRE BLVD 16th,17th-fl	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.06282	-118.36187	energy plan check 16th and 17th fl	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34681	16041-20001-44175	8460 N PENFIELD AVE	91306	3	192B113   270	2782010033	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.2237	-118.56872	expedite per applicant.pv1install roof mounted pv system sized 12.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34682	16041-10000-38600	13000 W PIERCE ST	91331	7	207B161   231	2536016013	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.26505	-118.41608	Remove HID fixtures and replace with new LED fixtures. Outdoor Title 24 only. Total sqft = 31984	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34683	18041-10000-11417	4551 S GLENCOE AVE 320	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC for T24 only for office renovation TI. Installing new lights, panel and receptacles. Total area 3559sqft.#18016-10000-90459.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34684	16041-10000-05574	5080 N AVENIDA ORIENTE	91356	3	171B125   726	2181014004	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	34.16282	-118.53152	Installation of roof-mounted solar PV system, not exceeding a total AC output of 8.6 kW, in a 1 or 2 family dwelling(2) INVERTER: ABB 4.2 KW (30) MODULES: SUNPOWER 327 WTHIS IS PC ONLY PER INSPECTOR REQUEST. EXPRESS PERMIT WAS ISSUED ONLINE. 16041-90000-02020	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34685	15041-10000-43188	4219 S DALTON AVE	90062	8	114B193  1061	5021013012	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.00671	-118.30365	PV1 for a residential home. Intalling 4.2 kw inverter, 18 modules, distrubution panel 125 Amps.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34686	17041-10002-30687	1139 W 80TH ST	90044	8	099B197   658	6033020023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	33.96658	-118.29544	Changes to an approved set of plans. Changes include adding two AC disconnects on the single line diagram for the AC powerwalls.Note: Permit is pulled under PCIS#17041-10000-30687	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34687	15041-10001-42678	11538 N JEFF AVE	91342	7	213B177    25	2529018021	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	ADDRESS	34.27992	-118.36454	04/15/2016PC for a new roof solar system using micro inverters. (25) Yingli Energy modules (25)  Enphase215 micro-inverters. Total System size 5.3 KW. With a pv monitor circuit. Fees are low due to Senate Bill 12222.Note: inspection fees were paid under express permit 15041-70000-42678(((Install a roof mounted photovoltaic system to existing single family dwelling (6.375       KW)Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34688	13041-10000-03397	650 S HILL ST Suite #414	90014	14	129A211   215	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.04623	-118.25392	TI IN AN EXISTING COMMERCIAL AREA IN SUITE # 414. PLAN CHECK FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34689	19041-10002-06363	2439 N RIVERSIDE PL	90039	13	148-5A211 150	5440026008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			PC Approved	02/26/2019 12:00:00 AM	ADDRESS	34.10129	-118.25338	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY ADDING 2 NEW AC DISCONNECTS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34690	19041-20001-23942	3737 S WATT WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			PC Approved	11/15/2019 12:00:00 AM	ADDRESS	34.01921	-118.28872	11/15/19CHANGES TO APPROVED SET DELTA 2 AND 3 CLOUDED AREAS.<<<Plan check for power only. replace 800A panel board and new ATS Emergency panel. Existing panel boards to remain.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34691	11041-20000-15469	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM			PC Approved	07/25/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	Ti in an existing office. EPC is for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34692	18041-20000-03395	7751 W VERAGUA DR	90293	11	099B153    56	4114002018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Expired	03/18/2024 12:00:00 AM	ADDRESS	33.96509	-118.43308	install (2) tesla powerwalls to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34693	14041-10000-23287	5248 N SHEARIN AVE	90041	14	163-5A223 114	5669028024	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/26/2016 12:00:00 AM	ADDRESS	34.14235	-118.21022	Installation of roof mounted solar system.  System size = 8.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34694	10041-10000-07441	3831 S HUGHES AVE	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Issued	04/28/2010 12:00:00 AM	ADDRESS	34.02242	-118.39823	Fire alarm system for 7 story combination medical and parking building.  The medical office portion of the building shall be done separately from the common areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34695	19041-10001-46632	6025 N FAIR AVE	91606	2	177B173   998	2337006005	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.18032	-118.3748	PC FOR CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REVISING BACK-FEED CIRCUIT BREAKER TO 60A AND CONDUCTOR SIZE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34696	16041-10000-10364	725 S FIGUEROA ST Suite 4150	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	T-24, Interior office TI with a showroom, Scope of work includes new lighting and receptacles. Total sq. ft. 1654.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34697	19041-20000-06372	6410-6512 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.1873	-118.64251	Plan check for power only. Project site is an existing commercial shopping center. Project scope is changing existing electrical services from overhead to underground.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34698	11041-20000-23607	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I.  Renovation of the Northridge Mall's  open area and the restrooms light fixtures and adding a new panels with new circuits.Request for Modification to separate Fire Alarm system filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34699	19041-10000-18786	962 N MALTMAN AVE	90026	13	142-5A203 120	5427022003	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.08598	-118.27953	(ePlan) New 7.6 kW AC/ 6.27 kW DC and 5.767 kW AC CAC rooftop solar system on (E) SFD. Install (19) roof mounted PV solar panels with (19) P400 optimizers, (1) 7.6 kW inverter, system connect to 200A main service panel .*Note: Panel upgrade shall be under separate permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34700	18041-20000-47182	4341 N CHERRY HILLS LANE	91356	3	165B117   257	2178025029	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.1488	-118.56236	Plan check for a PV1 roof-mounted PV system. System size is 15.87 kWdc/14.1 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (46) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34701	11041-10000-20641	1037 S DOREEN PL BLDG 34	90291	11	111B145   879	4243003031	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	33.9997	-118.45939	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34702	19041-10000-28297	14000 W TERRA BELLA ST	91331	6	201B153  1049	2642001002	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.24363	-118.43814	PV 1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER. (19) MODULES AND (1) 7.8 KW INVERTER. TOTAL SYSTEM SIZE IS 7.0 KWAC/5.89 KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34703	18041-20001-09941	7600 N BALBOA BLVD 202	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Revisions to approved set.  Minor panel schedule changes and change of lighting fixture.  Approval for signed clouded revisions only. (((PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. RETAIL . UNIT 202)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34704	19041-20000-23168	12426 N SAN FERNANDO ROAD	91342	7	219B149   516	2507007023	P-1-CPIO, [Q]M1-1-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	02/08/2021 12:00:00 AM		Issued	02/08/2021 12:00:00 AM	ADDRESS	34.29621	-118.45435	2000A 480Y/277V 3ph-4w service, distribution, power, and lighting for indoor nursery.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34705	19041-30000-13335	1515 S HOLT AVE	90035	5	129B173   567	4303012102	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.05074	-118.37913	Plan check for a fire alarm system for a 5-story, 21-unit apartment building. Fire alarm consists of (1) FACP and (106) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34706	16041-10000-35137	454-518 E COMMERCIAL ST	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.05313	-118.23621	NEW FA SYSTEM FOR LADOT BUS MAITENANCE & CNG FUELING FACILITY. FA DEVICES 70 AND 11 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34707	11041-10000-25470	1333 S BEVERLY GLEN BLVD 1-61	90024	5	135B157   450	4327003***	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Issued	01/23/2012 12:00:00 AM	ADDRESS	34.06319	-118.42688	Installing a new feeder from generator to two elevators, to be tapped off existing feeder.  System will recall both elevators to first floor, and keep only one elevator operational.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34708	15041-10001-29675	6438 E YORK BLVD	90042	14	153A233   227	5492036008	[Q]C4-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	ADDRESS	34.1138	-118.18036	(9/16/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 1.  RELOCATING DEVICES FROM WALL MOUNT TO CEILING MOUNT USING EXISTING CIRCUITS.  THIS IS PLAN CHECK ONLY.NEW FIRE ALARM SYSTEM TO AN (E) COMMERCIAL BUILDING. 24 FIRE DEVICES, 1 FIRE ALARM PANEL AND 2 COMMUNICATION PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34709	16041-20000-01356	6171 W CENTURY BLVD #300	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	Plan check for energy only. TI to existing office on 3rd floor (suite 300). New lighting (incl. emergency) and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34710	16041-10000-42770	10352 N LAS LUNITAS AVE	91042	7	204B197  1151	2565010065	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.25732	-118.2912	PV1 roof mounted solar system installtion to a single family home. Installing a central inverter rated at 5.0 Kw being fed by 21 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34711	09041-10002-18276	432 N FAIRFAX AVE	90036	5	141B177  1334	5527030021	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM			PC Approved	02/23/2010 12:00:00 AM	ADDRESS	34.07914	-118.36128	ORIGINAL PERMIT/PLAN CHK APPROVAL INCLUDED  A SINGLE OVERHEAD DROP TO SERVICE DISTRIBUTION BOARD. MS1. PER DWP, A TAP FROM THE DROP WAS MADE TO EXISTING SERVICE DISTTRIBUTION BOARD MS2 TO SUPPLY PANEL C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34712	18041-10000-34547	4551 S GLENCOE AVE 230	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	33.9844	-118.43407	T-24, PC FOR ENERGY ONLY. TI FOR AN EIXSTING OFFICE SPACE FOR SUITE 230. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2922 SQ. FT. B#18016-10000-29211	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34713	17041-20000-15635	700 S NEW HAMPSHIRE AVE	90005	10	132B197   232	5094011018	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Issued	06/14/2017 12:00:00 AM	ADDRESS	34.05951	-118.29274	Plan check for solar pv system, roof mounted on commercial building.9.6kW ungrounded system. (40) EnPhase M250 microinverters.(40) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34714	15041-20000-01601	523 W 6TH ST SUITE 410	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS.  USING EXISTING PANELS.  TOTAL SQUARE FOOTAGE 3727. SCOPE OF WORK TO BE PERFOMED IN SUITE 410.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34715	16041-10000-02947	4333 N FORMAN AVE	91602	4	165B177   569	2424022007	RE11-1-H-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.14909	-118.35284	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.340KWdc / 15.2KWac.(59)MODULES-YINGLI ENERGY YL260P-29B(2)INVERTER-FRONIUS 7.6-1PERMIT FEE OF $0 IS DUE TO Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34716	19041-20001-12595	19458 W OXNARD ST	91356	3	177B117   728	2153031015	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	34.17817	-118.55704	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. MINOR SERVICE EQUIPMENT RELOCATION. CLOUDED CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34717	14041-20000-01972	11450 W OXNARD ST	91601	2	177B169   816	2338011024	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	PIN	34.17916804	-118.38083573	pv1 single family dwelling. total system size 3.8 kw ac using transformerless inverter nonstandard plan with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34718	10041-10000-13116	6380 W WILSHIRE BLVD	90048	5	135B173   874	5088014021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	ADDRESS	34.06348	-118.36826	title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34719	12041-10000-24804	431 S FAIRFAX AVE	90048	5	135B177   121	5510001030	C2-1VL-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM			PC Approved	10/17/2012 12:00:00 AM	PIN	34.06895703	-118.36171214	TITLE 24 ENERGY, FOR SMALL PORTION OF FLOOR, IN A FOUR STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34720	14041-10001-30027	8471 W BEVERLY BLVD Ste 105	90048	5	138B173   428	5514012025	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	34.07621	-118.37572	Title 24 Part 6 plan check review for express permit issued under 14041-10000-30027.(((ADDING 6 RECEPTACLES AND 1 CANLIGHT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34721	19041-10000-23558	6080 W CENTER DR 1st Floor	90045	11	102B169   954	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	CHANGE OF USE FROM OFFICE TO RESTAURANT ON THE GROUND FLOOR IN ROOMS 116, 121 & 150 N A HI-RISE BULDING. CHANGE ANOTHER SUITE TO BE THE KITCHEN AREA FOR THE RESTAURANT. INSTALL NEW PANELS, TRANSFORMER & LOADS. AREA: 3,612 SQR FT. BULDING PERMIT: 18016-10000-39548	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34722	11041-20000-04564	735 S FIGUEROA ST suite 310	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.04878	-118.26079	energy plsn check suite 310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34723	14041-20001-05297	7300 N SYLVIA AVE	91335	3	186B117   869	2104029022	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.20311	-118.5523	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34724	15041-20000-03180	10900 W WILSHIRE BLVD FLR 15-18	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.05848	-118.44419	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANELS.  NEWLY CONNECTED LOAD > 400 AMPS PLAN CHECK FOR POWER AND ENERGY.  SCOPE OF WORK IN FLOORS 15-18.  TOTAL SQUARE FOOTAGE 43000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34725	14041-20002-02818	15935 W GRESHAM ST	91343	12	195B141   407	2672024014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM			PC Approved	05/22/2014 12:00:00 AM	ADDRESS	34.23116	-118.47966	changes to approved set of plans. changes clouded delta 1this is a plan check only application. ZERO FEES DUE TO 2012 SENATE BILL NO 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34726	17041-10000-46470	5112 S BABETTE AVE	90066	11	105B161   471	4221011066	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	33.98506	-118.41654	PC FOR ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (200A), SINGLE BATTERY RATED AT 5.8KWac WITH EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34727	14041-20000-02014	6310 W SAN VICENTE BLVD SUITE 340	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.06084	-118.36757	TI HIGHRISE OFFICE. SCOPE OF WORK ON SUITE 340	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34728	10041-20000-06793	2019 E 7TH ST	90021	14	124-5A217 224	5164020015	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.03473	-118.23158	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34729	13041-10001-36257	8640 W WENTWORTH ST	91040	7	207B189   184	2555002055	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	34.26681	-118.3214	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 4 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (16) Modules: Trina Solar TSM-250PA05.18.(16) Optimizers: Solaredge OP250-LV-AH4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34730	17041-10000-41755	247 S NORMANDIE AVE	90004	10	135B193    81	5518001030	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.06983	-118.30072	Remove Outdoor HID fixtures and replace with new LED fixtures. T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34731	19041-10000-08085	10250 W SANTA MONICA BLVD UNIT 1610	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Issued	06/14/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	CONVERTING ADJACENT SPACE FOR A RESTAURANT INTO  AREA  FOR FOOD PREPARATION  AND STORAGEPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34732	13041-10000-04191	6607 W 88TH ST	90045	11	096B165   907	4122019013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	33.95731	-118.40485	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. TOTAL SYSTEM SIZE 2.16KW. USING MICROINVERTER ENPHASE M215-60-2LL-S22. USING 10 PANELS. REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34733	18041-10000-15976	18300 S VERMONT AVE	90248	15	063B197   168	6121020011	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	33.86507	-118.29032	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34734	18041-10000-31206	10100 W SANTA MONICA BLVD 2525	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Issued	08/29/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	PC FOR OFFICE TI FOR T-24 ENERGY ONLY IN HIGH RISE. SCOPE INCLUDES NEW CIRUCITS AND LIGHTS. TOTAL AFFECTED AREA 6555 SQ.FT B# 18016-10000-21130	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34735	19041-20000-22157	1245 N VINE ST	90038	13	144B185   204	5533005001	C2-1D, RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			06/11/2019 12:00:00 AM			PC Info Complete	09/13/2019 12:00:00 AM	ADDRESS	34.09382	-118.32681	Plan check for power only service upgrade to 1200A to existing multi-family building 97 units 5 story building, new distribution sections and panel inside the units, existing branch circuit inside the unit to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34736	13041-20000-35511	1440 S SEPULVEDA BLVD	90025	5	129B149    38	4324016094	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.05107	-118.44699	PC FOR NEW SERVICE ONLY. REPLACEMENT LIKE FOR LIKE, 2500A SWITCHGEAR. CHANGED FROM FUSED D/C TO CIRCUIT BREAKERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34737	19041-20000-47147	5757 W WILSHIRE BLVD	90036	4	135B177   594	5508015009	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 Energy only  total area: 1183 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34738	14041-10000-14405	11223 S HINDRY AVE	90045	11	087B173   102	4129037007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.93221	-118.37248	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL  AREA 5969 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34739	19041-20000-25976	350 S GRAND AVE 33rd Floor	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only. Project site is the 33rd floor of an existing commercial building. Project scope is a common area improvement. Total lighting area = 2,354 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34740	15041-10000-01054	9301 N TAMPA AVE #134	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVMENT, INTERIOR NON BEARING PARTITIONS IN (E) RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34741	13041-10000-08849	5031 N FAIR AVE	91601	2	171B173  1095	2353012016	R4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			04/05/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.1617	-118.37478	ADDITION OF NEW FIRE PUMP TO AN EXISTING SYSTEM. 5 FEEDERS REDUCED IN SIZE CHANGED FROM COPPER TO ALUMINUM. 6 MORE FEEDERS ALSO CHANGED FROM COPPER TO ALUMINUM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34742	13041-10000-08113	4966 N HOOD DR	91364	3	171B113   498	2175020003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	34.16176	-118.56867	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS. TOTAL SYSTEM SIZE: 5.39 KW. [INVERTER: SOLAR EDGE SE5000A-US] [SOLAR MODULE: TRINA SOLAR TSM-245 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34743	18041-20000-40552	20280 W VIA CELLINI	91326	12	219B113    88	2701046019	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.29295	-118.57557	Plan check for a PV1 roof-mounted PV system. System size is 16.92 kWdc/15 kWac and consists of (47) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34744	12041-10000-01624	8378 W MELROSE AVE 2nd flr-3rd flr	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	03/07/2012 12:00:00 AM	ADDRESS	34.08341	-118.37285	T.I. to an existing 3-story office building.  No emergency lighting.  PLAN CHECK ONLY for Energy on the 2nd and 3rd floor, (No suite number per applicant)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34745	19041-10000-05573	736 N FULLER AVE	90046	5	141B181   369	5526008005	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.0847	-118.3497	NEW ROOF MOUNTED 9.45 KW PV SYSTEM WITH 31 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34746	19041-20000-41384	11825 W TERRA VISTA WAY 132	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/11/2023 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34747	11041-10000-15448	1122 N COLE AVE	90038	13	144B185   487	5533009901	OS-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.09133	-118.32971	RENOVATION OF POOL BUILDING.  NEW SERVICE, PANELS, LIGHTING AND CIRCUITS AND RELOCATING PANELS AND EQUIPMENT.    PLAN CHECK IS FOR POWER AND ENERGY.  PLAN CHECKER TO VERIFY WITH APPLICANT TO PAY FEES FOR OUTDOOR LIGHTING IF APPLICABLE FOR OUTDOOR LIGHTING AROUND BUILDING AND POOL AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34748	14041-10000-15802	8111 N REDBUSH LANE	91402	6	192B153  1194	2213003036	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.21891	-118.43747	PV1, Install 6.63 KW DC roof-mounted solar array on a 0ne-story house, interconnect with main service panel. Transformerless inverter. With optimizer.(26) Modules: Trina Solar # TSM-255pa05.18(1) Inverter: SOLAREDGE #SE6000A-US-ZB-.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34749	11041-20000-01289	11611 W SAN VICENTE BLVD 9th Floor	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Closed	08/19/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	Plan check T24 Energy (general/emergency) lighting for office TI on the 9th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34750	12041-20000-27408	6917 N WOODMAN AVE	91405	2	183B157   678	2216025015	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Apartment			11/14/2012 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.19617	-118.43151	New 2-story, 10-unit apartment building with 600 amp service.  Full Plan Check Required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34751	18041-20001-40332	837 S THAYER AVE	90024	5	135B153   267	4360017037	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	34.06607	-118.43483	11/13/2018 Changes to an approved set of plans. All changes have been clouded. MSP and PV meter have been relocated. Module layout has changed but count has remained the same. Note: $0.00 fee due to CA Senate Bill 1222*****Previous Work Description*****PV1.  Install 10.552 kW AC-CEC roof mounted grid tied PV system.  (34) AC modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34752	10041-20000-19007	1261 N ANGELO DR	90077	5	144B153   454	4357012002	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	01/27/2012 12:00:00 AM	ADDRESS	34.09187	-118.43619	New fire alarm and central smoke detector system for new custom SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34753	19041-10000-10420	1040 N LAS PALMAS AVE STG 3/8	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	INSTALLATION ON NEW FACP WITH 5 DEVICES IN STAGE 3/8	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34754	12041-10000-07382	19128 W CASTLEBAY LANE	91326	12	219B121   261	2820010015	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.29436	-118.54999	Plan check for new 7.848KW roof mounted photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34755	15041-20000-39732	2018 N HIGHLAND AVE	90068	4	150A185    63	5575023004	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.10715	-118.33728	Install new 70 devices fire alarm system in an (E) 4-story hotel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34756	19041-20000-47724	13263 N WHEELER AVE 9	91342	7	225B157  1056	2512010026	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34757	18041-20000-07904	2040 N MCPHERSON AVE	90032	14	136-5A233 297	5215034024	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	PIN	34.06685306	-118.18102604	pv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34758	15041-20002-05934	6855 N TUJUNGA AVE	91605	2	183B173   210	2320003002	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.19546	-118.37923	**supplemental2: adding xformer  150KVA and panel PCHANGES TO APPROVED SET OF PLANS. UPGRADING SERVICE TO 1200 AMPS.Power plan check for 800 A service upgrade in existing commercial building. Plan approve per Elie.M	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34759	12041-10000-17372	638 E GAGE AVE	90001	9	105B205  1046	6007018004	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	33.98174	-118.26376	PLAN CHECK POWER FOR INSTALLATION OF (3)  30,000 GALLON LPG STORAGE TANKS. NEW DEVICES TO EXISTING EMERGENCY SHUT DOWN SYSTEM BRANCH CIRCUIT. WIRING IN HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34760	11041-10001-09166	7060 W HOLLYWOOD BLVD 1st  floor	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Closed	12/15/2011 12:00:00 AM	ADDRESS	34.10137	-118.34379	"LIGHTING  AND ELECTRICAL PLANS WERE REVISED TO SHOW THAT THERE ARE 2 EA EMERGENCY GENERATORS FOR THIS HIGH RISE BUILDING. EMERGENCY LUMINAIRES ARE TO BE SUPPLIED FROM EMERGENCY CKT LEA-23; EXIT SIGNS WILL ALSO BE CONNECTED TO CIRCUIT LEA-23. LUMINAIRES ON THE EMRGENCY CKT WILL NO LONGER BE DESIGNATED ""NL"". ALL BATTERY PACKS WILL BE REMOVED. (((((((((NEW RESTAURANT IN EXISTING RETAIL SPACE.  FULL PLAN CHECK."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34761	16041-10005-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.23567	-118.5584	"11/07/18Plan Check only. CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 11. CHANGES INCLUDE NOTES FOR FUTURE TENANTS AND REMOVAL OF LIGHTING IN TENANT SPACES.  ((((THIS IS PLAN CHECK ONLY!DELTA ""3R1"" CHANGES TO APPROVED PLANS DATED 6/14/2018. SCOPE OF WORK INCLUDES THE CHANGE OF LIGHTING LAYOUT IN THE CORRIDOR SPACES, REVISIONS TO PHOTOMETRIC IN ALL AFFECTED AREAS, CHANGES TO AIC RATING IN THE RESIDENTIAL SECTION FROM FULLY RATED TI SERIES RATED AND CHANGES TO BREAKER SIZES IN THE UNITS PANEL FROM 20A TO 15A. <<<PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE  APARTMENT WITH 215UNITS.   AND RESTAURANT/ RETAIL CORE & SHELL.  FOUR FLOORS OF RESIDENTIAL OVER TWO FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL. THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMP, 4000 AMP, AND 1600 AMP.  TOTAL AREA = 408,828 SQ. FT.>>> )))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34762	16041-10000-34557	742 S MAIN ST	90014	14	127-5A211 192	5145001011	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.04304	-118.25239	PC for energy only. Remove HID fixture and replace with new LED fixture. Total sqft = 11564	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34763	10041-10000-11892	7604 N LOUISE AVE	91406	6	186B133   222	2203005025	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.20882	-118.50965	New gas station no food, title 24 lighting and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34764	18041-30000-35561	350 S GRAND AVE 18TH FL.	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	PLAN CHECK FOR T24 ONLY,  TENANT IMPROVEMENT WORK ON +/- 12,295 SQFT. OF THE EXISTING 18TH FLOOR SUITE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34765	18041-10000-08038	7930 N ALABAMA AVE	91304	3	189B105   252	2110005019	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.21474	-118.59928	REPLACE INDOOR-OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 11900 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34766	12041-10001-03435	6801 W HOLLYWOOD BLVD #257	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM			PC Approved	09/24/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	REVISED LIGHTING SYSTEM -DECREASE IN INSTALLED LIGHTYNG WATTAGE-PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34767	19041-10000-03024	3500 W WILSHIRE BLVD SUITE #104	90010	10	132B193   108	5094001020	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.04	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.06157	-118.30077	FULL PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENTS(7ELEVEN ). CHANGE OF USE FROM RESTAURANT TO RETAIL. SCOPE INCLUDES NEW PANELS AND CIRCUITS TO AN EXISTING MULTI TENANT SWITCHBOARD, 2000A SERVICE RATED AT 120/208V.  TOTAL AFFECTED AREA = 3766 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34768	19041-30001-02682	2000 S AVENUE OF THE STARS 900 N	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	05/07/2019 Changes to an approved set of plans. Changes include the expansion of the scope of work to include a portion of the 10th floor. Total lighting area on the 10th floor is 832 sq. ft.*****Original Work Description*****TI OF 9th FLOOR, EXISTING OFFICE AREA IN SUITE # 900N. T-24 ENERGY ONLY. 23,645 Sqr Ft. Building Permit: 18016-10000-39126	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34769	17041-10000-10281	651 E 53RD ST	90011	9	108B205   320	5103005024	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Refund in Progress	10/13/2017 12:00:00 AM	ADDRESS	33.99426	-118.26397	PC FOR PV SYSTEM USING 6 MODULES AND CENTRAL INVERTER 3KW AC. pv is rooftop solar	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34770	12041-10000-13528	2512 W HILL DR	90041	14	163-5A221  46	5682015001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	08/13/2012 12:00:00 AM	ADDRESS	34.1442	-118.21973	Plan check for new 14.388KW roof mounted photovoltaic system for single family dwelling. Additional permit to upgrade service panel and branch circuit for monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34771	15041-10000-19220	4101 S REDWOOD AVE BLDG B	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			Reviewed by Supervisor	06/30/2015 12:00:00 AM	ADDRESS	33.99086	-118.44043	SERVICE RECONNECT FOR BUILDING B FROM BUILDING A UNDER APPLICATION NUMBER 15041-10000-19214.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34772	13041-20000-18246	9123 W MONTE MAR DR	90035	5	129B169  1125	4305022009	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Expired	08/05/2015 12:00:00 AM	ADDRESS	34.04739	-118.38858	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW USING 15 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34773	18041-20000-41315	6854 S LA TIJERA BLVD	90045	11	102B173   149	4103002028	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	ADDRESS	33.97614	-118.37283	ti with an 800 amp service upgrade.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34774	18041-10000-14325	2121 S AVENUE OF THE STARS #2500	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	Energy plan check for an office T.I. Scope includes new lighting and equipment located on the 25th floor of a highrise building. Total area is 9258-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34775	17041-20001-09897	12601 W PIERCE ST Bldg 14	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 14).3.5kW ungrounded system. (7) AP Systems YC500i microinverters. (14) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34776	17041-10000-41160	1241 W 73RD ST	90044	8	102B197  1291	6019010024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	33.97377	-118.29763	PC for 4.750kW rooftop solar. Installng 19 modules with microinverters and AC combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34777	13041-10001-34969	11991 N NUGENT DR	91344	12	216B129   178	2601051018	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.28926	-118.5161	][][PLANS NOT EXPEDITED; VOID THIS SUPPLEMENTAL PC #. THIS 10001-SERIES WAS GENERATED FOR EXPEDITING FEE-ESTIMATE ONLY. EXPEDITED NOT PAID FOR ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL IN 2-STORY BUILDING; NON-STANDARD PLAN. SYSTEM IS TRANSFORMERLESS, & SIZED @ 9kW DC, WITH THE FOLLOWING ITEMS:(36) MODULES: ET-P660250(2) INVERTERS: POWER-ONE-PVI-3.6-OUTD-US (1) 60A LOADCENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34778	17041-10000-11950	10990 W WILSHIRE BLVD suit 400	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM			PC Approved	04/12/2017 12:00:00 AM	ADDRESS	34.0577	-118.44711	Energy plan check for an office T.I; Total area is 6300 SQ ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34779	13041-10001-23800	11205 S BROADWAY	90061	8	087A203   167	6074024002	R3-1	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Apartment			08/30/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	33.93272	-118.27879	EXPEDITED PER APPLICANTS REQUESTPV 2 ( APARTMENT).  ROOF MOUNTED SOLAR SYSTEM. NEGATIVELY GROUNDED CENTRAL INVERTER SYSTEM. SYSTEM SIZE:36.6 KW DC , 33.1 KW AC. 112 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34780	13041-10001-23913	12468 N LONGACRE AVE	91344	12	219B125   123	2601075059	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM			Reviewed by Supervisor	10/08/2013 12:00:00 AM	ADDRESS	34.29631	-118.53624	EXPEDITED PER APPLICANTS REQUESTPV1. PLAN CHECK FOR ROOF MOUNTED SOLAR ARRAY. POSITIVELY GROUNDED.  SYSTEM SIZE 13.8 KW.  40 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34781	18041-20001-11054	7510 N HAZELTINE AVE	91405	2	186B153    97	2215015012	M1-1, MR1-1, P-1VL, R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.20701	-118.43985	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 99.9 kWac/117.95 kWdc and consists of (3) inverters, (337) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34782	15041-10000-38784	600 WORLD WAY SPACE 680	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, NEW  KIOSK  FOR CURRENCY EXCHANGE ON ARRIVAL LEVEL. PC FOR ENERGY ONLY TOTAL SQ. FT. 65.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34783	15041-10000-16217	11100 W SANTA MONICA BLVD SUITE 200	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.04726	-118.44465	ALTERATIONS IN OFFICES/OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34784	16041-20001-30483	21830 W NORDHOFF ST	91311	3	198B105   190	2779020056	QMR1-1, QP-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM			PC Approved	03/14/2017 12:00:00 AM	ADDRESS	34.23521	-118.60422	[[[[3/14/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. T24 CHANGES ONLY. REPLACING ALL L1 FIXTURES TO L2 FIXTURES ]]]]Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from a restaurant to a dental office. Total lighting area = 4,334 sq. ft. Note: Building permit has been pulled under 16014-20000-02868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34785	14041-20000-18770	106 N POINSETTIA PL	90036	5	138B181   812	5512020021	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.07391	-118.34849	PV1Install roof mounted solar array on SFD. Three strings to combiner. System Size: 6kW.(1) SMA SB6000TL-US-22 transformerless inverter(18) SunPower SPR-X21-345 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34786	14041-20000-03658	7008 N STANSBURY AVE	91405	6	183B153   579	2217015020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.19795	-118.44095	Roof mounted PV system with 6.5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34787	10041-20000-05874	8151 W MELROSE AVE	90046	5	141B173   392	5528006050	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM			PC Approved	03/31/2010 12:00:00 AM	ADDRESS	34.08389	-118.36712	Changes to 09041-20000-09222 Title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34788	12041-10000-13904	9255 N SUNLAND BLVD OFF. BLDG	91352	6	198B173    88	2408002023	M1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.23755	-118.36793	NEW OFFICE BUILDING.  PLAN CHECK FOR POWER & ENERGY.  permit fees are Splited between the two bldgs see #   12041-10001-13904.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34789	19041-20000-32514	3488 W 8TH ST	90005	10	132B193   623	5093015019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			PC Info Complete	08/20/2019 12:00:00 AM	ADDRESS	34.05752	-118.30617	Plan check for Title 24 only in existing space Tenant Improvement Restaurant in kitchen and bathroom area. Total area: 593 sq ft. B#17016-10000-28168	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34790	15041-10000-33455	8821 S PERSHING DR # 2	90293	11	093B153   150	4117028029	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	33.9532	-118.44046	PV1, INSTALL NEW 4.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON #2 UNIT APRTMENT OF AN APARTMENT BUILDING.(16) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-ANote. Application should be under residential instead of commercial	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34791	19041-20000-53384	16633 W VENTURA BLVD #602	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	04/05/2020 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for Ttle 24 Energy only for new indoor lighting. Total area: 2065 sq ft. B#19016-20000-38917	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34792	14041-20001-07215	20300 W TAU PL	91311	12	207B113   245	2707017015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	34.2609	-118.57574	Fee for expedite only.*****Roof mounted PV system with size 10KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34793	17041-20003-22680	3660 W WILSHIRE BLVD	90010	10	132B193    63	5093019020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM			PC Approved	06/14/2019 12:00:00 AM	ADDRESS	34.06155	-118.30505	6/14/2019changes to an approved set of plans.  changes to remove AC disconnect from system wiring.this is plan check only.  3/7/2019CHANGE TO APPROVED SET, CHANGE FROM 790 PHONO SOLAR 325W PV MODULES TO 765 LONGI SOLAR 345W PV MODULES.THIS IS PLAN CHECK ONLY.((((Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,052) modules, and (1) load center.Note: Permit Fees $0 due to SB 1222Note: Building application has been generated under 17014-30000-03171))))((((7/31/2018changes to an approved set of plans.  changes to decrease system size to 180KW AC.  Line side tap.this is plan check only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34794	14041-10005-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			04/12/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	33.95605	-118.38499	Supplemental PC for approved set. Changes included adding new circuits and equipment. All changes clouded under detla 7.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34795	14041-10000-12638	823 S MARIPOSA AVE	90005	10	132B197   604	5094018013	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.05705	-118.2989	PV1, INSTALL  2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER AND WITH OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34796	14041-10000-01304	2714 S PORTLAND ST	90007	9	123A201   277	5123002409	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.0293	-118.28289	REMODELING 2-STORIES FRATERNITY BUILDING;1ST FLOOR ARE COMMOMAREAS AND 2ND FL INSTALLING EM LIGHTING IN THE CORRIDORS INSTALLING LIGHTING IN THE COURTYARDPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34797	19041-20000-34983	201 W WASHINGTON BLVD	90015	14	123A207    51	5126027007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.03222	-118.26683	Plan check for Title 24 only in existing space Total area: 1584 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34798	16041-20000-37251	1755 W 52ND ST	90062	8	108B193   122	5003005028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	33.99518	-118.30865	Plan check for a fire alarm system for a single-story charter school. System consists of (1) FACP, (1) annunciator, and (35) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34799	12041-10001-17970	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	THE APPROVED SET OF PLANS WERE REVISED PER LAWA'S REQUEST: LOADS WERE SHIFTED FROM THE ORIGINAL PANELBOARDS; UPGRADE KITCHEN AND OTHER CHANGES AS OUTLINED IN LIST PROVIDEDTI FO RTHE FIRST CLASS LOUNGE AND JOINT LOUNGE AT THE EXISTING AND NEW 5TH FLOOR OF THE TOM BRABLY TERMINAL  AT  LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34800	12041-10001-24275	800 W WORLD WAY 8A	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	PIN	33.94153561	-118.3984113	PLAN CHECK FOR REVISION TO APPROVE PLANS. CHANGES TO FLOOR LAYOUT, T24 ENERGY, AND THREE CIRCUITS ADDED. .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34801	14041-20000-16633	22144 W VALERIO ST	91303	3	186B101   653	2023012004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.20451	-118.60963	New roof mounted PV system with Optimizers and transformerless inverter.  Total system size 4.08KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34802	13041-20005-35614	12005 W BLUFF CREEK DR BLDG 1	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	33.98179	-118.40283	PC FOR CHANGE TO AIC RATING AND FAULT VALUES. CHECKING NEW RATINGS AT VFD AND RELOCATED SITE LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34803	18041-20001-43435	320 S AVONDALE AVE	90049	11	129B137   277	4406024011	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.05103	-118.49108	Expedited plan check fee.PV1.  Install 11.52 kW DC roof mounted grid tied PV system.  (32) modules with 11.4 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34804	18041-10000-36574	957 W 88TH ST	90044	8	096A199   108	6038010902	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			09/25/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	33.95803	-118.29064	NEW FIRE ALARM SYSTEM IN A 40 UNIT APARTMENT BUILDNG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34805	19041-30000-02524	14612 W CALVERT ST	91411	6	177A151    14	2241022029	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.18153	-118.45136	Plan check for a fire alarm system for a 4-story, 19-unit apartment building. Fire alarm system consists of (1) FACP and (78) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34806	17041-10000-12151	24105 S FRAMPTON AVE	90710	15	039B197    42	7439011038	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	33.805	-118.29924	PC for power only for new 600 A switchboard, 225KVA transformer, panelboard and circuits in a warehouse. Electrical work only, no structural work so no building permit was filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34807	15041-10001-25408	20255 W HARTLAND ST	91306	3	183B113   781	2135036015	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.19481	-118.57503	EXPEDITE PER CUSTOMER REQUEST. (((PV1 PC FOR ROOF MOUNTED SOLAR SYSTEM AT RESIDENTIAL SITE. (2)INVERTERS: POWERONE PV1-5000-OUTD-US-A & POWER ONE PV1-6000-OUTD-US-A. (32) MODULES : SPR327NE-WHT)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34808	18041-20002-24987	7219 W WARING AVE	90046	5	141B181   258	5525002038	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM			PC Approved	09/06/2018 12:00:00 AM	ADDRESS	34.08537	-118.34686	Revisions to approved set of plans.  Change of module type from JA Solar 360W to S-Energy 355W.  $0 plan check fee per State Senate Bill SB 1222 and AB 1414. (((Plan check for a PV2 roof-mounted PV system. System size is 69.12 kWdc/62.95 kWac-CEC and consists of (3) inverters, (192) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34809	14041-20000-08387	10637 N SYLVIA AVE	91326	12	207B117   282	2728003022	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.26375	-118.5523	PV1.  Roofmounted PV system,  9.5kw with optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34810	19041-10000-52201	15400 W SHERMAN WAY	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	01/02/2020 12:00:00 AM		Issued	01/02/2020 12:00:00 AM	ADDRESS	34.20099	-118.46839	T-24 ENERGY ONLY PLAN CHECK FOR A TENANT IMPROVEMENT TO AN EXISTING OFFICE/CLASSROOMS. SCOPE OF WORK INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTICAL AND CONTROLS. TOTAL AFFECTED AREA IS 7,088 SQ.FT*POWER PLAN CHECK MAY BE REQUIRED SUBJECT TO FIELD INSPACTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34811	14041-10000-09154	635 W USC MC CARTHY WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.02103	-118.28214	FIRE ALARM PANEL UPGRADE TO AN EXISTING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34812	18041-10000-41207	10880 W WILSHIRE BLVD Basement-Lobby	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Closed	10/08/2020 12:00:00 AM	ADDRESS	34.05885	-118.44283	TI IN THE BASEMENT LOBBY AREA OF AN EXISTING HIRISE. INSTALLING TEMPORARY LIGHTS. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34813	18041-20001-18778	268 S VAN NESS AVE	90004	4	135B189   173	5516010011	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.06921	-118.31543	Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (33) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34814	12041-20000-03533	1740 N BEL AIR ROAD	90077	5	147B149    85	4371003009	RE40-1, RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Expired	12/16/2014 12:00:00 AM	PIN	34.10218103	-118.44769563	single family residence	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34815	14041-10000-11672	5418 S ASCOT AVE	90011	9	108B209   592	5104010025	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	33.99351	-118.24978	Install roof-mounted solar array interconnect with main pannel.System size = 2.5 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34816	12041-10000-01790	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM			PC Approved	01/30/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans for the north  and south concourses at TBIT -GDN 062	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34817	15041-10000-43207	735 S BERENDO ST	90005	10	132B197   333	5094009016	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			12/22/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.05876	-118.29429	PV2, ROOF MOUNTED SOLAR SYSTEM TO A TENANT IN AN APARTMENT BUILDING.  (8) MODULES AND (1) CENTRAL INVERTER-3KW-AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34818	12041-10000-24288	5160 N VINELAND AVE # 107	91601	4	171B173  1378	2419001042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.16418	-118.37009	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT (LESS THAN 50 OCCUPANCY) UNIT #107. PERMIT FOR NEW BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34819	17041-20000-10064	9171 N DE SOTO AVE BLDG A	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.23778	-118.5888	(N) 1 STORY RETAIL BLDG SHELL ONLY.  Plan check for power and energy.  Building A.  Building B permit is being submitted concurrently on same set of plans.  Building permit filed under 17010-20000-00221.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34820	18041-10000-26579	7270 WORLD WAY WEST SAP-21	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	06/21/2022 12:00:00 AM	ADDRESS	33.94145	-118.42037	"PLAN CHECK FOR POWER AND ENERGY FOR SECURED ACCESS POST ""SAP#21"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34821	10041-10000-24353	2025 S FIGUEROA ST	90007	9	123A205    30	5126003025	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	ADDRESS	34.03246	-118.27359	Fire Pump Installation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34822	12041-20000-26278	18616 W INGOMAR ST	91335	3	189B121   575	2103025047	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2012 12:00:00 AM	12/24/2012 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.21184	-118.53892	New 11.0kw rooftop mounted photovoltaic system for an existing single family residence.  Plan check is Only for the PV system and NOT for de-rating the main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34823	14041-10000-01728	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT IN WESTFIELD TOPANAGA MALL. 750 SQFT, EMERGENCY LIGTHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34824	19041-10000-10827	1599 W JOHN S GIBSON BLVD	90731	15	024B201     6	7440016907	[Q]M3-1VL	Harbor	Port of Los Angeles	Northwest San Pedro	YES	9800.31	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	12/02/2020 12:00:00 AM	ADDRESS	33.7654	-118.28199	T24 FOR A TRUCK PARKING LOT. SCOPE OF WORK INCLUDES: NEW LIGHTING AND SERVICE. TOTAL SQUARE FOOTAGE 496,160	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34825	14041-10000-33236	6121 W SUNSET BLVD	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	FIRST TIME TENANT(RESTURANT) TO (E) CORE AND SHELL BUILDING. TOTAL AREA 3041 SQ FT.B# 14016-10000-24395.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34826	17041-10000-11653	10250 W SANTA MONICA BLVD UNIT 1230	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PLAN CHECK FOR ""TUMI"" - SUITE 1230, 1,405 SQ.FT. ALL ELECTRICLA EQUIPMENT ARE EXISTING BUT FEW NEW BRANCH CIRCUITS."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34827	18041-10000-38044	900 W LOMITA BLVD	90710	15	036B197    60	7413019001	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	33.79756	-118.29102	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34828	16041-10000-45639	1016 W D ST BLDG 2	90744	15	027B201   420	7417010946	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM				PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING(LOT 5, BLDG 2). SCOPE INCLUDES 43 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34829	19041-10001-17260	12207 W HESBY ST	91607	2	171B165   916	2356014019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM			PC Approved	06/14/2019 12:00:00 AM	ADDRESS	34.16227	-118.39893	Expedite per applicant request.(((Plan check for a 9.6kw AC roofmounted system with (30) AC modules, (2) battery power supplies, and (3) subpanels interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34830	17041-10001-15949	331 N GRENOLA ST	90272	11	126B121   464	4414024020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.04163	-118.54243	Service upgrade with (N) 150A main circuit breaker, installation of (N) 125A load center, and (N) 5.8 kVA optional standby system(tesla-power wall)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34831	16041-30000-15026	3242 E 6TH ST	90023	14	123A227   201	5186015023	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM			Reviewed by Supervisor	05/10/2016 12:00:00 AM	ADDRESS	34.03166	-118.20093	Plan check for PV roof mounted system. System size: 2.3kW ac with 9 panels and 9 microinverters. Submit per applicant.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34832	14041-10001-07882	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.22149	-118.43179	((11/24/2014- CHANGES MADE TO APPROVED SET, RELOCATED TRANSFER SWITCH FOR TRANSFER OF POWER FOR THE TEMPORARY GENERATOR)) PLAN CHECK FOR POWER IN KAISER PERMANENTE BLDG. UPGRADING TO NEW SYSTEM, NEW PANELS, SWITH GEARS AND TRANSFORMERS. NUMBER OF DEVICES PER APPLICANT AND MEHDI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34833	19041-10000-24385	1050 S FALCON ST	90744	15	021B205    13	7440019908	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	ADDRESS	33.75638	-118.26559	PC FOR WORK IN HAZARDOUS LOCATION IN POLA. SCOPE INCLUDES RELAMPING IN BERTH 167-169 OF 25 LAMPS CHANGING FROM HID TO LED - REPLACEMENT OF 2 HORNS ABOUT 3 NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34834	13041-20000-23572	8379 W 3RD ST	90048	5	138B173   748	5511015015	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.0731	-118.37273	T24 FOR HAIR SALON. NOT A FIRST TIME TENANT AND TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. 1899 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34835	15041-10002-30939	11455 W BURBANK BLVD BLDG A&B	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	CHANGES TO THE APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 11 AND 12. CHANGES INCLUDE: ADDING LIGHTING CONTROLS, LIGHTING SCHEDULES, AND CHANGES TO T24 FLOOR PLANS /CALCULATIONS. ADDITION OF ONE 1600A PULL SECTION FOR FUTURE USE, CHANGES OF  FAULT CURRENT AND AIC RATINGS,  AND ADDITION OF SMOKE FIRE DAMPERS. THE DRAWING PLAN INCLUDES BULIDINGS A, B AND C IN ONE SET CHANGES TO BE REFLECT ON THE FIELD. (((((TI to an exisiting religious assembly site (2-story building), Church of Scientology-Areas A &B. All equipment is new except the service. Full Plan Check for power and energy. Total Sq ft = 65,971.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34836	14041-10000-16585	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	TI in terminal 6 in LAX.  Plan check for power and lighting.  Total area = 250 sq. ft.Provide lighting, electrical distribution, 20 kVA UPS system, and power for 1 renovated space used as an IT room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34837	15041-20000-38549	9714 N MASON AVE	91311	12	201B109   213	2748012054	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.2468	-118.57963	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34838	16041-10001-31546	755 W CAPITOL DR	90731	15	024B197   409	7445001800	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	33.75875	-118.29459	CORRECT WORK DESCRIPTION. PC FOR POWER SYSTEM ONLY. THIS APPLICATION WILL COVER DELTA 8 REVISIONS. REVISED MAIN SERVICE ENTRY TO INCLUDE METHANE PULL SECTION AND CUSTOMER SERVICE CABLES. THIS APPLICATION IS PLAN CHECK ONLY. PERMIT ALREADY COVERED UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34839	18041-20000-17979	19327 W VENTURA BLVD F	91356	3	174B117   299	2163001006	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.17286	-118.55453	Renovation of (E) commercial space.  Install new lighting and controls for Title 24 Part 6 compliance.  New show window receptacles.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34840	14041-10000-24973	1940 S CREST DR	90034	5	126B169   345	4302008035	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Expired	11/14/2016 12:00:00 AM	ADDRESS	34.04353	-118.38841	PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34841	14041-10000-05700	15003 W VICTORY BLVD	91411	6	180B145   783	2235021048	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			03/03/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.18681	-118.45977	PLANCHECK FOR POWER AND ENERGY FOR A NEW 17 UNIT 3 STORY APARTMENT BUILDING.Fire Alarm Variance has been filed.BUILDING P #14010-20000-00067	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34842	15041-10000-16779	3006 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.02698	-118.4281	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2085.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34843	16041-20000-26771	421 N HELIOTROPE DR 1-60	90004	13	141B197  1173	5520016022	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.07839	-118.29606	permit fee $0.00 by state senate bill no.1222Install a roof-mounted solar array on an Apartment building. Interconnect with a 400A MSP. Derating main breaker from 400A to 250A. 40kW ungrounded system [4*10kW]. (176) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34844	11041-20000-15246	10135-10141 N SAN FERNANDO ROAD Building B	91331	6	204B161   502	2623032027	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.25434	-118.40996	"PLAN CHECK POWER AND ENERGY FOR RETAIL ON 10135 -10141SAN FERNANDO (BUILDING B) AND NEW 3000A SERVICE IN BUILDING B. BUILDING B SUPPLYING  600A TO FUTURE 10133 SAN FERNANDO (BUILDING A) AND 1200A TO EXISTING OFFICE BUILDING. SITE ON METHANE BUFFER ZONE. METHANE TEST REPORT LEVEL I, <=2"" WATER COLUMN. NO METHANE MITIGATION REQUIRED FOR METHANE BUFFER ZONE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34845	16041-10000-40888	6437 N KESSLER AVE	91367	3	180B113   742	2134040026	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.18759	-118.56732	Installation of a roof mounted solar system. (25) new microinverters rated at 280W each. Total system size is 7.0 KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34846	13041-20000-00782	11724 N PORTER VALLEY DR	91326	12	216B117   352	2822030004	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.28449	-118.55372	Enphase system on roof of single family dwelling with PV subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34847	10041-10000-23809	1149 S HILL ST #650	90015	9	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	04/21/2011 12:00:00 AM	ADDRESS	34.03926	-118.26099	TI IN AN EXISTING CLASSROOMS ON THE 6TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34848	13041-10000-15123	1166 W 36TH PL 1-5	90007	8	120B197  1044	5040030009	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			06/10/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.02185	-118.29359	New three story apartment with first level parking garage.  Install new 400 A service, panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34849	16041-20001-00652	8666 W FOOTHILL BLVD	91040	7	204B189    15	2560003029	C2-1VL, P-1VL, QC2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.25956	-118.3221	Original approved plans lost; plan check only for Title 24 Part 6 requirements.  (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/fire rebuild. Total lighting area = 1,550 sq. ft.Note: Building permit has been pulled under 15016-20000-00727)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34850	18041-20000-07667	1495 S MATEO ST	90021	14	121-5A217 256	5167001043	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.02706	-118.23238	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34851	15041-20000-27349	15120 W SEPTO ST	91345	7	201B145   143	2660022009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.25075	-118.4618	Installation of new roof mounted solar PV array.  Total system size = 3.25 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34852	19041-10000-20639	14943 W LEMAY ST	91405	6	180B145   142	2235007026	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.19226	-118.45899	PV1. New LADWP Community Solar Program: 3.00KWdc / 2.40 kW AC - 10 solar modules and 10 enphase IQ7-60-2 micro-inverters. 1 circuit. 1 service. interconnected through meter adapter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34853	14041-10000-16627	4070 N BAKMAN AVE	91602	2	162B173   299	2366033032	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.14196	-118.37785	PV1 ROOF MOUNTED MICROINVERTER SYSTEM. ENPHASE 250. TOTAL SYSTEM SIZE 3.1KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34854	17041-10000-31938	20221 S HAMILTON AVE	90502	15	054B197    33	7351033022	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	33.84695	-118.28626	New Fire alarm system to an (E) 2 story commercial build.  (4) panels,  (83) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34855	15041-10001-35171	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	33.76094	-118.29308	Supplemental Plan check. Revision noted under Delta-1, consists of revision on racking system, modules, and inverters. (per M.Z)<<PV2, SOLAR ROOF MOUNTED SYSTEM TO AN (E) COMMERCIAL BUILDING, TARGET. TOTAL SIZE 364 KW, AC. (1547) MODULES AND (13) INVERTERS. (1547) JINKO JKM310P-72(13) SOLELECTRIA PV1-28TL-480>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34856	13041-10000-34430	1510 S CLOVERDALE AVE 1-5	90019	10	129B181  1223	5070014019	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.04617	-118.35222	APARTMENT. HAVE SUPERVISOR CHANGE DESCRIPTION. NOT A SFDPV1, Install a 3.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) inverter(s)[SOLAREDGE # SE3800A-US] and (14) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34857	11041-20000-07415	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/13/2011 12:00:00 AM			PC Approved	04/13/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I.  TITLE 24 PLAN CHECK ONLY.  EXISTING RETAIL SPACE .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34858	12041-20000-11834	1999 S AVENUE OF THE STARS 21st floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.05886	-118.41642	Remodel of a portion of the 21st floor, energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34859	14041-20000-26395	8101 N BOBBYBOYAR AVE	91304	12	189B093    72	2020019017	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Expired	11/02/2016 12:00:00 AM	ADDRESS	34.2174	-118.63349	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.0KW INTERCONNECTED TO MSP.(56) KYOCERA KD255 MODULES(2) SOLAREDGE 6000 INVERTERS(56) POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34860	13041-10000-08144	4600 W COLORADO BLVD	90039	4	162B205   273	5593018903	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.14094	-118.27314	Replace unit substations construct new 5kv switch gear.original plan check by francis. due to delay of time to issue permit, applicant is resubmitting plans for plan check. original approved set of plans have been included. 09041-10000-24259	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34861	15041-10000-10058	3651 S WATT WAY #719	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.02013	-118.28812	New power outlets and lighting in (E) laboratory space on USC campus.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34862	15041-20000-27650	380 N CAROLWOOD DR	90077	5	141B157    10	4358006033	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.08562	-118.4289	New 20,000 sqft. single family residance. Adding new 1000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34863	16041-10002-30643	835 W JEFFERSON BLVD 7-D	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	PC FOR POWER AND ENERGY FOR A FIRST TIME TENANT FOR A PERVIOUSLY APPROVED TITLE 24  SET. SCOPE INCLUDES CHANGES IN LIGHTING AND ADDING NEW LOAD. NEW CONNECTD LOAD FOR EQUIPMNET AND RECEPTACLES. *******************************************************(TI FOR OFFICE SPACE IN EXISTING ROOM. NEW LIGHTING. WORK DONE IN BUILDING 7 SUITE 7-D PC FOR T24 ENERGY ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34864	16041-20000-13562	7337 N WOODVALE CT	91307	12	186B093   694	2027006***	(Q)RD6-1, RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.20369	-118.63343	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.36 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34865	13041-10001-35881	431 W 7TH ST 5TH AND 6T-H	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM			PC Approved	12/02/2014 12:00:00 AM	ADDRESS	34.04654	-118.25516	plan check only. Supplemental  to the original plan because of changing plan more than %40. Permit has to be pulled under the original application. Original plan checker was Mathew Tan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34866	12041-10000-15154	8141 S GULANA AVE	90293	11	096B153     1	4115021800	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	33.96169	-118.43753	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. EXISTING GAS COMPANY WEST AND EAST COMMERCIAL BUILDING. PERMIT FOR WEST BUILDING. EAST BUILDING PERMIT UNDER #12041-10000-15160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34867	15041-20001-38571	20754 W LUGANO WAY	91326	12	213B109   283	2701065001	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.27826	-118.58526	EXPEDITE PER APPLICANT REQUEST{{{{{Plan check for PV roof mounted system. System size: 10.0kW with 46 modules and 1 inverter(10.0kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34868	15041-20002-36207	700 WORLD WAY SPACE 7C	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	[1/13/16  changes to approved plans. delta 2 t24 changes only. changes to lighting design.]]] Changes made to approved plans.  Changes to lighting design, minor changes in location of some equipment.    (((PROPOSED TENANT IMPROVEMENT FOR  CHANGE OF USE FROM  FOOD & BEVERAGE CONSSECION TO RETAIL PREPACKAGE FOOD.PC for Power and Energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34869	16041-10000-44384	1011 N WESTERN AVE	90029	13	144B193   925	5536021024	C4-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.08906	-118.30941	"Plan check for Power and Energy of New Restaurant ""Chick Fill A"". 1200 MSA, total area indoor+outdoor 10,163 sq.ft"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34870	12041-20000-24578	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.15886	-118.50032	"Modification to previously approved set of plans.  Change to lighting, receptacles, loads.Previously approved set of plans  under 12041-10000-14874.((((Permit fee is under ""Inspection Fee Period""))))    Major electrical change is the addition of two 6000W water heaters (instantaneous type).<<<<Plan check for power and energy. Dental Office. 2200 sqft. Low rise commercial building (6 floors).>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34871	13041-20000-25818	11555 W NATIONAL BLVD	90064	11	120B153   745	4258015033	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	34.02401	-118.43641	PV2 (Church) NEGATIVELY GROUNDED SYSTEM. 8.1KW SYSTEM. 4 STRINGS AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34872	19041-10000-25963	3115 W ADAMS BLVD	90018	10	123B189   653	5059028007	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	11/19/2021 12:00:00 AM		Permit Closed	12/03/2021 12:00:00 AM	ADDRESS	34.03279	-118.31817	CHANGE OF USE & OCCPANCY OF (E) 1ST FLOOR OF SFD  TO A TEMPLE USE ONLY & 2ND FLOOR TO REMAIN AS EXISTING  INCIDENTAL RESIDENTIAL USE WITHOUT KITCHEN-BEDROOMS AND BATHROOMS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34873	12041-20000-30350	601 S FIGUEROA ST 39th floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			Reviewed by Supervisor	12/28/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	Change to lighting in an existing office space on the 39th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34874	13041-10000-17719	4501 W COLORADO BLVD street	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.14246	-118.2705	permit to be pulled at EPC counter only. nonhazardous according to applicant. TI TO EXISTING AREA. OUTDOOR LIGHTING FOR BAXTER HEALTHCARE BIOSCIENCE. installation of  277V 10 pole lights, 3 building lights, and 10 landscape lights. sump pump and panel BADA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34875	19041-10000-23479	9165 N WINNETKA AVE Bldg 3	91311	12	198B113   212	2748039030	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			Corrections Issued	02/04/2020 12:00:00 AM	PIN	34.2368297	-118.57294016	Full plan check for a new Industrial Warehouse Building core and shell (Building 3).Scope includes new 2000A service. Total affected area 5247 sq.ft 3 of 3B#19010-10000-01406	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34876	13041-10000-03321	5414 N WOODLAKE AVE	91367	3	171B093    27	2042007019	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.16876	-118.63186	PV1 for 2 story house. Total system size: 7.2 KW. 30 Modules used. [Invertor: Fronuis Model#: IG PLUS 75-1 @ 7.5KW] [Solar Module:Trina Solar Model#: TSM-240 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34877	19041-10000-33131	189 S THE GROVE DR SUITE K20	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	T-24 PLAN CHECK FOR A TI TO AN EXISTING RETAIL STORE IN SUITE# K20. SCOPE INCLUDES REVISED LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1944 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34878	17041-10000-08044	1128 S SHENANDOAH ST 1-6	90035	5	132B169   615	4332019006	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			03/13/2017 12:00:00 AM	11/15/2018 12:00:00 AM		Issued	11/15/2018 12:00:00 AM	ADDRESS	34.05632	-118.38136	PC for new 6 unit 4 story apartment with 1 level of subtarranean parking. PC includes 600A 120/240 service. Building located in a methane zone. Building permit under 14010-30000-01834.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34879	11041-20001-05168	8937 N SAN FERNANDO ROAD	91352	6	195B169   259	2631017051	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.23104	-118.3853	CHANGE THE APPROVED PLAN  FOR 800 AMP SERVICE. EPC IS FOR POWER. TI PLAN WAS SUBMITTED UNDER SEPARATE APPLICATION.  ((((((((((((((PLAN CHECK POWER FOR NEW SERVICE UPGRADE TO 800A.)))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34880	14041-10000-19201	1062 S STEARNS DR	90035	5	132B173   727	5087019025	R1-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.05692	-118.36878	PV1 10KWAC. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {SMA 10000TL-US}]. [(42)modules: {solarworld SunModule SW-270 mono }]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34881	16041-10000-19200	1840 S CENTURY PARK EAST 14TH FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE ON THE 14TH FLOOR. TOTAL AFFECTED AREA IS 14291 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34882	13041-20001-28534	6060 W WILSHIRE BLVD BASEMENT	90036	4	135B177   526	5086009014	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM			PC Approved	05/02/2014 12:00:00 AM	ADDRESS	34.06273	-118.36103	Modifications to approved set.  Changes to number of fixtures (overall reduction in installed lighting power).  Customer submittal of modified sheets E-0.01, E-2.01, and E-3.01.    (((TI for basement level of a 3-story museum, conversion of storage space to office.  Title 24 plan check only for lighting.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34883	16041-20000-27834	20168 W JUBILEE WAY	91326	12	213B113   400	2701087036	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.28241	-118.57399	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34884	17041-10000-05272	1217 S WOOSTER ST	90035	5	132B169   853	4332015027	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.05517	-118.38277	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 9,775.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34885	15041-10000-04897	9731 N VARIEL AVE	91311	12	201B105   148	2746004030	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.24737	-118.59306	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL  AREA 6160 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34886	15041-10000-10397	11473 W PENROSE ST	91352	6	192B169   428	2632023061	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.22187	-118.38165	T24 ONLY. REMOVE HID LLIGHT FIXTURES AND REPLACE  WITH NEW LED LIGHT FIXTURES, TOTAL AREA 14354 SQ FT (8834 SQ FT INDOOR + 5520 SQ FT OUTDOOR).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34887	11041-10000-21971	726 E WASHINGTON BLVD	90011	9	121-5A209 161	5131006006	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.02711	-118.25667	T.I. to an existing warehouse.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34888	17041-20000-14697	12370 N TELFAIR AVE	91342	7	219B145   492	2604032026	RE9-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.29518	-118.46073	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.97 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34889	17041-10000-06037	4211 N EAGLE ROCK BLVD	90065	14	156A219   107	5473024024	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.12229	-118.22486	PC FOR POWER AND ENERGY FOR A COMMERCIAL TI (NEW TARGET)TOTAL CONNCTED LOAD MORE THAN 400ATOTAL AFFECTED AREA 33070 SQ.FT BUILDING APP #$ 17016-30000-04010APPLICANT PROVIDED PRE CUT CHECK. PLAN CHECKER TO VERIFY ALL FEESCOUNT HAS NOT BEEN VERIFIED PER MHADIPLANCHECKER TO UPDATE ENGINEER ON RECORD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34890	14041-20000-24756	10739 W STALLION RANCH ROAD	91040	7	204B177   260	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM			Verifications in Progress	02/03/2015 12:00:00 AM	ADDRESS	34.25715	-118.36484	New Ground Mounted PV system with Enphase Microinverter, model M215-60-2LL.  Total system size 26KW (Plans shows 30KW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34891	19041-30000-12918	322 S ROBERTSON BLVD	90048	5	138B169   646	4334011032	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.07284	-118.38362	"Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to beauty parlor/tenant improvement. Total lighting area = 941 sq. ft.""COMPLY WITH DEPARTMENT ORDER effective date03/04/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""Note: Building permit has been issued under 19016-20000-06149"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34892	13041-10001-34534	12510 S VERMONT AVE	90044	15	081B197   234	6117017044	R2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	33.91811	-118.2914	Expedited RSES plan check per applicant request.{{PV1, Install  4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] on a 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34893	14041-10000-34351	11333 N DE FOE AVE	91331	7	210B161    45	2533008011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	34.27605	-118.41897	PV1, INSTALL 5.98 KW DC SOLAR RRAY ON A SINGLE DWELLING HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR327NE-WHT-D(1) INVERTER: POWERONE PVI-6000-OUTD-S-US-A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34894	17041-30001-16377	469 W 6TH ST	90731	15	015B197   390	7455005008	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	33.73863	-118.28724	Plan check for Title 24 only for lost set of plan in existing space T.I. retail due to fire damage. Total area: 598 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34895	16041-10000-28551	6245 W WILSHIRE BLVD	90048	5	135B177   481	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Closed	03/15/2018 12:00:00 AM	ADDRESS	34.06356	-118.36478	PC FOR TEMP POWER. USING GENERATOR CONNECTION FOR CONSTRUCTION EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34896	17041-10000-17108	11641 N CORBIN AVE	91326	12	213B113   277	2701057900	PF-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.28132	-118.5698	PC FOR BATTERY STORAGE SYSTEM. SYSTEM IS BOTH UTILITY INTERACTIVE AND STANDBY LOAD TRANSFER CAPABILITY. TOTAL SYSTEM STORAGE IS 40KWH WITH MAX 12KW (TWO 6KW INVERTERS) BACKFEED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34897	17041-10000-36256	10250 W SANTA MONICA BLVD # 2740	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Info Complete	12/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for first time tenant "" STITCH + TRACE"" ste. 2740 on Westfield Century City"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34898	15041-20001-40916	17046 W COTTER PL	91436	5	162B133    91	2292010029	A2-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/14/2015 12:00:00 AM	ADDRESS	34.14293	-118.50458	Expedited plan check fee per applicant request. PV1.  Install 24.4 kW DC roof-mounted, utility-interactive PV system.  (75) SunEdison F325BzC modules with (2) DC combiner boxes and SolarEdge SE10000A-US transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34899	19041-10000-34088	5215 N FIGUEROA ST	90042	1	150A227    70	5468017025	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.10664	-118.19915	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34900	18041-30000-07170	2029 S CENTURY PARK EAST 25st Floor-lobby	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing space elevator lobby on 25st floor. Total area: 295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34901	19041-10000-43820	4121 W SANTA MONICA BLVD SUITES 103-104	90029	13	145-5A201 370	5429002035	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM	04/22/2020 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	34.09205	-118.28241	Plan Check for Power & Energy. Installing New Panels, Circuits & Lights.((((First Time Tenant. Bldg Permit: 19016-10000-34456 - PROPOSED 1-STORY GROCERY MARKET, TENANT IMPROVEMENT WITHIN (E) COLD SHELL RETAIL SPACE OF FULLY SPRINKLERED BLDG.  (N) SALES AREA WITH REFRIDGERATED CASES, GOURMET KITCHEN/FOOD PREP AREAS.  JUICE BAR, WALK IN REFRIDGERATORS AND FREEZER, STOCK ROOM, OFFICES AND SEATING AREA.  NEW ELEVATOR AND REFRIDGERATION SERVING TYPICAL MARKET AMENITIES.  (NO CHANGE OF USE))))) 2 services , 1600A each under 18041-10003-16557	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34902	12041-10000-17468	12400 W BRANFORD ST	91352	6	201B165   117	2629001004	(T)(Q)M2-EZ1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1048.10, 1212.10	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.24795	-118.40337	PLAN CHECK FOR NEW INSTALLATION OF MATERIAL HANDLING SYSTEM FOR NEW FEDEX DISTRIBUTION WAREHOUSE. (MAIN SERVICE APPROVED UNDER EPC #11041-20000-20733)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34903	16041-20001-12064	11411 N PORTER RANCH DR	91326	12	213B113   325	2701072004	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.27855	-118.57253	[[[1/11/18  CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING TO LOAD SIDE CONNECTION AND DERATING MAIN]]]Plan check for a PV2 carport PV system. System size is 120 kWac and consists of (8) inverters, (480) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34904	14041-10000-23699	905 E 2ND ST 1-320	90012	14	129A215   386	5163003***		Central				2060.31	Electrical	Electrical	Apartment			08/29/2014 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.04729	-118.23499	New fire alarm system for a 5-story mixed occupancy building with 2-lower level parking .  Total # of devices = 1263, (1) fire alarm panel, (2) communication panels, and (13) control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34905	15041-20001-06541	8431 N AQUEDUCT AVE	91343	12	192B141   301	2673014037	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	34.22385	-118.47438	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (21) modules, and (1) inverter.Note: Standard Plan is NOT being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34906	17041-10000-34940	4308 W SUNSET BLVD	90029	13	145-5A201  87	5429006011	C2-1D	Central	Hollywood	Silver Lake		1913.02	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.09467	-118.28331	PC FOR RETAIL TI. FOR A YOGA STUDIO (796 SF) AND RETAIL (804 SF) TITILE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, CIRCUITS, EQUIPMENT AND LIGHTING. TOTAL AFFECETED AREA 1600 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34907	17041-10000-02262	10001 S FIGUEROA ST	90003	8	091-5A201 114	6054020005	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	33.94534	-118.28289	PC for outdoor Tile 24 only. Remove HID fixtures and replace with new LED fixtures. Area: 19,500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34908	16041-10000-20644	612 E 11TH ST	90015	14	124-5A211 178	5145025001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.03561	-118.25307	FULL PC. CHANGE OF USE FROM WAREHOUSE TO BAR, LOUNGE AREA AND RESTROOM, TOTAL OCC. IS 142 PER BUILD. APP. TOTAL AREA: 5,240 SQ. FT. (INDOOR+OUTDOOR)B# 15016-10000-27912	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34909	18041-20004-15077	7600 N BALBOA BLVD STE 109	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM			PC Approved	08/05/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	Clouded delta 9 changes only. Change to an approved set of plan, Changes include revised panel schedule loads, change to light models and wattages, change to floor plan symbols, and change to T24 installed wattages.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34910	10041-20001-15103	3131 S FIGUEROA ST Room #118	90007	9	120A203    61	5123010012	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM			PC Approved	09/14/2010 12:00:00 AM	ADDRESS	34.02389	-118.27894	PLAN CHECK ONLY. REVISION TO APPPROVED PLANS. DELTA 2 REVISION ONLY. CHANGING FIXTURE TYPES. LIGHTING FOR FILMING ARE EXEMPT FROM T-24 AND ARE SWITCHED SEPERATELY. TI IN AN EXISTING COMMERCIAL AREA Room #118.    PLAN CHECK IS FOR T-24 ENERGY CALCS.REF.#10044-10000-08248.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34911	13041-10000-04262	601 S FIGUEROA ST 8-9	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	TI OF 2 FLOORS OF HIGH RISE. WORK TO BE DONE ON LEVEL 8 AND 9. POWER PLAN CHECK AND ENERGY PER SUPERVISOR. PERMIT FOR BRANCH CIRCUITS HAS ALREADY BEEN ISSUED PER PERMIT #13041-90000-04240 AND 13041-90000-04241	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34912	16041-20000-17569	333 S GRAND AVE 20th Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check Title 24 only in high-rise existing space office.  Lighting in open space is less than 10% in that area. Total area: 1,525 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34913	16041-20000-44200	5170 N SEPULVEDA BLVD 140-170	91403	4	171A145    43	2263002041	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Issued	01/30/2017 12:00:00 AM	ADDRESS	34.16461	-118.46592	Plan check for power and energy. Project site is an existing OSHPD-3 medical office. Project scope is the addition of a new operating room and recovery room as well as (E) tenant space improvement. Total lighting area = 3,196 sq. ft.Note: Building permit has been issued under 16016-30000-18110/16016-30001-18110	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34914	11041-10000-27504	18801 W VENTURA BLVD #105	91356	3	174B121   472	2160002030	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM			PC Approved	12/28/2011 12:00:00 AM	ADDRESS	34.17184	-118.54317	Plan check T24 Energy/Emergency lighting for Army Recruiting Station TI (Suite #105)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34915	16041-20000-17028	1108 S LOS ANGELES ST unit 100	90015	14	126A209   262	5145021022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.03808	-118.25716	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAKL SQUARE FOOTAGE 2045.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34916	13041-20000-20523	19242 W BERNETTA PL	91356	3	171B117   319	2163008018	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.16471	-118.55266	solar plan check service upgrade  9.31 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34917	15041-20002-43876	543 W 121ST ST	90044	15	084B201  1267	6117003014	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2016 12:00:00 AM			PC Approved	02/10/2016 12:00:00 AM	ADDRESS	33.92262	-118.28453	01/27/2015 Changes to an approved set of plans. Changes have been made to reflect field installation. All changes have been clouded and marked as Delta 1 and 2.*****Previous Work Description*****PV1, rooftop solar installation interconnect with 400A MSP. System size: 11.4 kw(44) Q.PRO BFR-G4(44) M215-60-2LL(1) 125A load center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34918	15041-20000-38196	20230 W WELLS DR	91364	3	168B113    80	2175029009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.15986	-118.57324	PV1, roof mounted solar panel, 6.625kW DC system (25)modules #KU2656ZPA, (1)inverter:PVI-6000-OUTD-US-Z-A   Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34919	11041-10000-21436	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	09/12/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	First time tennant at LAX terminal 5 / space 5A.  Plan check for POWER and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34920	15041-10000-40105	21040 W CALIFA ST	91367	3	174B105     8	2149002021	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.17715	-118.59163	NEW FIRE ALARM SYSTEM TO A DIALYSIS CENTER. 75 FIRE ALARM DEVICES AND 1 NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34921	15041-20000-35974	18857 W BRAEMORE ROAD	91326	12	216B121   190	2820015010	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM			Plans on Hold	11/03/2015 12:00:00 AM	ADDRESS	34.29062	-118.54451	Plan check for PV roof mounted system. System size: 3.8kW and 11 modules and 1 inverter(3.8kW). Standard plan is not being use.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34922	17041-20000-21863	7600 N BALBOA BLVD	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.2087	-118.50093	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34923	15041-10001-15981	2712 S HALLDALE AVE	90018	8	123B193   947	5053029003	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.03041	-118.30261	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 6.867 KW DC ROOF-MOUNTED SOLAR ARRAY ON A RESIDENTIAL HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: SUNPOWER SPR 327ne-wht-d(1) INVERTER: ABB PVI-6000-OUTD-US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34924	11041-20000-21310	1900 S AVENUE OF THE STARS #1100	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	ADDRESS	34.05979	-118.41671	PLAN CHECK T24 ENERGY/EMERGENCY TENANT IMPROVEMENT TO EXISTING OFFICE ON 11TH FLR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34925	18041-20001-46235	550 S WITMER ST	90017	1	132A207   193	5153022009	CW	Central	Westlake	Westlake North		2091.03	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM			Verifications in Progress	01/18/2019 12:00:00 AM	ADDRESS	34.0558	-118.26528	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 19.44 kWdc/16.52 kWac-CEC and consists of (2) inverters, (54) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34926	17041-20000-41529	23317 W SCHOENBORN ST	91304	12	192B093   321	2005011011	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.22052	-118.63547	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (26) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34927	14041-10000-30022	11400 W OLYMPIC BLVD	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	11/07/2014 12:00:00 AM	ADDRESS	34.03666	-118.44346	Title 24 plan check only.  Total area = 5,300 sq. ft.T.I. to existing commercial highrise space.  Lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34928	10041-20001-07804	3410 W 3RD ST	90020	13	135B197   307	5501024028	(Q)P-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM			PC Info Complete	01/25/2011 12:00:00 AM	ADDRESS	34.06884	-118.29027	Changes from previously approved plans.  Changes include relocate switchboard panels, branch circuits, and lighting.  All changes indicate by DELTA R1.  Plan check for energy and power.******NEW LIGHTING THROUGHOUT SALES AREA, NEW POWER FOR NEW FIXTURES.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34929	13041-10000-05198	17140 W NORDHOFF ST	91325	12	198B133   633	2690001012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.23562	-118.50737	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 7.35KW. TOTAL# OF MODULES: 30. [INVERTER: SUNNY BOY. MODEL#: SUNNY BOY 7000-US] [SOLAR MODULE: TRINA SOLAR. MODEL#: TSM-245 PC/PA05.08]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34930	18041-10000-00862	7851 W HILLROSE ST	91040	7	207A195    72	2556012046	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.26345	-118.30443	NEW ROOFTOP  SOLAR SYSTEM . CONSIST OF 19 MODULES ( TRINA TSM-300DD05A.08) WITH MICRO-INVERTERS (ENPHASE IQ6-60-X-US)). SYSTEM SIZE  IS 4.37 KWac AND 5.7KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34931	11041-20000-26562	15252 W SEPTO ST	91345	7	201B145   136	2660011018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.25081	-118.46498	New 1.38 KW roof mounted PV system for a single family residence.  Applicant is using M215 inverters.  A variance has been filed to use the microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34932	13041-10002-32778	6100 N TOPANGA CANYON BLVD	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.18131	-118.60555	Delta  4 changes: replacing garage luminares to a Listed  LED Parking Garage Luminaires PLAN CHECK FOR POWER AND ENERGY FOR A 4 STORY OPEN PARKING STRUCTURE. WESTFIELD MALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34933	12041-10000-06545	11135 W MAGNOLIA AVE #110	91601	4	171B173  1385	2350018082	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	05/21/2012 12:00:00 AM	ADDRESS	34.16512	-118.37384	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TRADE SCHOOL SUITE #110. PERMIT FOR NEW BRANCH CIRCUITS. CONNECTED LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34934	12041-20000-20353	4741 N LAUREL CANYON BLVD	91607	2	168B165   593	2356037036	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.15689	-118.39668	Plan check for PV. Commercial. 24.5kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34935	14041-10000-12380	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	LAX TERMINAL 1 2 NEW SWITCHBOARDS SERVED VIA NEW 5000A BUSWAY. ALL DISTRIBUTION EQUIPMENT IS NEW. **NOTE, FUTURE LOADS ON EACH SERVICE SHALL NOT EXCEED 2500 AMPS AFTER LOAD SHEDDING**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34936	19041-10000-20065	19712 W HART ST	91306	11	183B117   563	2135018024	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.19733	-118.56275	Plan check for a 3.8KW AC / 2.6KW DC roof mounted system with (1) inverter, (9) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34937	16041-10000-44618	10250 W SANTA MONICA BLVD # 1770	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM			PC Info Complete	01/24/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Allen Edmonds"" Ste. 1770.  Install new Xrfmr, and  panels, total area 946 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34938	12041-10001-01028	8601 S LINCOLN BLVD	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Expired	09/04/2014 12:00:00 AM	ADDRESS	33.95939	-118.41943	INTERIOR TENANT IMPROVEMENTS OF A VACANT SUITE AT PLAYA DEL ORO FOR LA FITNESS SPORTS CLUB WITH STATE OF THE ART HEALTH CLUB TO INCLUDE NEW FREE WEIGHTS, CIRCUIT, TRAINING EQUIPMENT, AEROBICS ROOM, SPINNING ROOM, <SEE COMMENTS>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34939	15041-20000-11209	10807 W BELLAGIO ROAD	90077	5	138B149    26	4362006006	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.07832	-118.45299	"""0$ permit fees due to senate bill 1222""Installation of new roof mounted solar PV array.  Total system size = 18 kWac.  Two inverter system with 5 strings."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34940	11041-20000-00848	5526 E YORK BLVD	90042	14	154-5A227  67	5478023039	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1833.00	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	PIN	34.11910464	-118.1969412	energy plan check subway restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34941	15041-20000-22980	11548 W VENTURA BLVD	91604	2	162B169   608	2369036002	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.13958	-118.38349	TI TO EXISTING RESTAURANT. ADDITION. NEW LIGHITNG. PC FOR T24 ENERGY ONLY. DUE TO BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDSPERMIT WILL EXPIRE WITHIN 30 DAYS FROM DATE OF ISSUANCE. SHALL COMPLY WITH DEPARTMENT ORDER. INVESTIGATION FEE FOR 2ND STORY ADDITION HAS BEEN COLLECTED UNDER THIS PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34942	15041-10000-06391	11766 W WILSHIRE BLVD Suite 800	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.04804	-118.46227	TI FOR EXISTING OFFICE SPACE ON THE 8TH FLOOR 5400 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34943	12041-20000-17092	512 E ROSE AVE Unit B	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	T-24 lighting plan check for sales floor area.  All lighting is provided by line voltage lighting track with integral current limiters rated 120 watts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34944	10041-10003-24535	13488 W MAXELLA AVE	90292		105B153    78	4212004012	[T][Q]RAS4-1-CDO		Palms - Mar Vista - Del Rey	Del Rey			Electrical	Electrical	Public Safety Only			03/22/2012 12:00:00 AM			PC Info Complete	03/22/2012 12:00:00 AM	ADDRESS	33.98592	-118.44252	Supplemental EPC for changes to the approved plan.   LAFD reduced the number of devices in the system.  All wiring and panels remain the same.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34945	15041-20000-03031	12481 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	33.9791	-118.41047	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34946	17041-20002-42366	13057 N GLADSTONE AVE	91342	7	222B157   135	2512002030	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.3074	-118.4246	Revisions to approved plans. Change of module layout on roof.  Approval of roof plans only.  $0 plan check fee per State Senate Bill SB 1222.(((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.32 KW.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34947	18041-10000-31245	350 W 5TH ST	90731	15	015B201    39	7455014035	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.73981	-118.28471	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34948	14041-20001-10263	6636 N HESPERIA AVE	91335	3	180B125   315	2122029018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.19143	-118.52611	EXPEDITE PER CUSTOMER REQUESTPV1 INSTALL ROOF  MOUNTED PV SYSTEM INTERCONNECTED WITH MAIN PANEL SIZED 6.1KW WITH TRANSFORMERLESS INVERTER (1) SOLAREDGE SE6000A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34949	13041-10000-20742	2110 W 7TH ST	90057	1	132A203   100	5141018002	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			Corrections Issued	08/05/2013 12:00:00 AM	ADDRESS	34.0565	-118.27737	Tenant improvement to existing restaurant building for new Carl's Jr. restaurant.  Newly connected load less than 400 A, title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34950	11041-20000-08485	5670 W WILSHIRE BLVD 19TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.06222	-118.35208	T.I.  EXISTING HIGHT RISE OFFICE BUILDING.  REPLACING AND INSTALLING LIGHTING FIXTURES.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34951	18041-10000-46789	2000 E CESAR E CHAVEZ AVE	90033	14	129A223   101	5183001029	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.04874	-118.21265	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34952	13041-10000-24959	400 S HOPE ST STE 700	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.05199	-118.25366	Tenant improvement in 12,548 sq. ft. office suite of a highrise building.  Title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34953	18041-10000-22237	885 S PIER A ST	90744	15	021B205   167	7440018905	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Issued	09/24/2018 12:00:00 AM	ADDRESS	33.75438	-118.27117	POWER PLAN CHECK FOR THE INSTALLATION OF 4 NEW MOTORS, OPERATING VALVES, AND CIRCUITS IN A OIL REFINERY.  HAZARDOUS LOCATION CLASS 1 DIVISION 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34954	18041-20000-22255	8568 W WALNUT DR	90046	4	150A173   601	5556013028	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.10447	-118.37831	Plan check for a PV1 roof-mounted PV system. System size is 13.65 kWdc and consists of (2) 5.2 kWac inverters, (1) load center, and (42) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34955	17041-10000-19712	633 S WARNER AVE	90024	5	135B153    47	4360021044	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			Reviewed by Supervisor	06/19/2017 12:00:00 AM	ADDRESS	34.06969	-118.43532	PC FOR POWER IN A SFD. NEW 600A  SINGLE PHASE  120/240V SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34956	16041-10000-00432	3351 S GAFFEY ST	90731	15	006B197     4	7469018904	OS-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.71374	-118.29306	NEW FIRE ALARM SYSTEM TO A POOL AND BATH HOUSE BUILDING. 39 FIRE ALARM DEVICES AND ONE FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34957	17041-20000-30992	4504 N BRUNSWICK AVE	90039	13	159B205   258	5593026010	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.13362	-118.26912	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  center fed panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34958	17041-10000-14477	5330 W LOMA LINDA AVE 1-8	90027	13	148-5A195  35	5544009021	R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Apartment			05/04/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	06/17/2022 12:00:00 AM	ADDRESS	34.10274	-118.30604	NEW 4 STORY, 8 UNIT,  APARTMENT OVER BASEMENT PARKING GARAGE. pc for power and energy B#14041-10000-03765	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34959	18041-20000-17521	6300 N CANOGA AVE Ste 1720-1740	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.18492	-118.59722	(E) commercial office remodel in highrise building.  New lights using existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34960	12041-10001-13219	7624 N VARNA AVE	91605	2	186B157   106	2303006014	CM-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.20931	-118.4246	T24 plan check for changes to lighting system per inspector's request.  (((Service upgrade to 400A for place of assembly building.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34961	18041-10000-18042	1026 S BROADWAY	90015	14	126A209    92	5139014017	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.04029	-118.25788	FULL PLAN CHECK IN A NEW CVS PHARMACY STORE. (POWER & ENERGY)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34962	14041-20000-17599	5900 W WILSHIRE BLVD # 550	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.06237	-118.35809	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT WORK ON 4,980 SQ.FT. OF THE TOTAL FLOOR AREA.  NEW WALL, FULL FLOOR SUSPENDED CEILING, POWER, LIGHTING AND FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34963	14041-20000-14613	6500 N WHITAKER AVE	91406	6	180B137   481	2231002017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.18881	-118.498	6.1KW roof-mounted system with (24) Trina Solar modules (TSM-255PA05.18), (24)  Solaredge Powerbox optimizers (#P300), and (1) Solaredge transformerles inverter (SE6000A-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34964	10041-20000-03988	637 W WILSHIRE BLVD # 100	90017	9	129A209    71	5144005031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	03/05/2010 12:00:00 AM		Permit Finaled	06/07/2010 12:00:00 AM	ADDRESS	34.04869	-118.25681	title 24 unit # 100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34965	10041-10000-18466	920 E PACIFIC COAST HWY	90744	15	036B209   665	7425003002	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	33.79072	-118.2518	addition of equipment to an existing service. hay sracker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34966	14041-20000-29517	2179 W 20TH ST	90018	10	126B193  1013	5073030060	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.03896	-118.31167	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(22) TRINA SOLAR TSM-250(1) ABB PVI-5000 TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34967	13041-10000-29549	18678 W KIRKCOLM LANE	91326	12	216B121    40	2870007002	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.29265	-118.54062	PV1.  Install 9 kW DC roof-mounted solar array, interconnect with main service panel.  Iinverter: Fronius IG Plus V 7.5.  36 modules: Hanwha Hsl60p6-Pb-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34968	16041-30000-37173	6500 S AVALON BLVD	90003	9	105B205  1196	6007018007	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	33.98013	-118.26497	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34969	17041-10000-02275	614-616 N HOOVER ST	90004	13	141A201    55	5401001017	C1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1959.03	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.08207	-118.28432	Plan Check for Power only in existing builidng Service upgrade to 600A 120/240V 3 phase 4W with distribution to multiple tenants of 614, 616, and 614-1/2 Hoover Street.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34970	15041-20003-17225	14857 W BESSEMER ST	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.18089	-118.45716	08-27-2015 Change to approved set of plan. Changes include addition of receptacles and lighting fixture manufacturer. Changes apply to delta 1 only. {{{{{{07-27-2015 Plan check for lost original set of plans, Title 24 only[[[[Plan check for Title 24 only for retail T.I. Total area: 2,400 SF.]]]]}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34971	18041-10000-05932	6120 W 3RD ST	90036	4	135B177    14	5509003003	C2-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.07028	-118.35377	FOR OFFICES IN A FINANCIAL INSTITUTION, LUMINIRE COMPONENT MODIFICATIONS ARE MADE-REPLACING LIGHT SOURCE TYPE TO LEDPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34972	18041-10000-21495	10643 N COMMERCE AVE	91042	7	207B197   955	2566008036	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.26238	-118.28861	Install PV1 rooftop solar system, 3.45 kW AC, (10) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34973	18041-10000-44463	6921 S LA TIJERA BLVD	90045	11	102B173   156	4103003015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.97563	-118.37395	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34974	15041-10000-14503	12484 W OSPREY LANE 1-3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	NEW FIRE ALARM SYSTEM FOR NEW 4 STORY BUILDING. SCOPE INCLUDES 37 FIRE ALARM DEVICES, 1 CONTROL PANEL AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34975	19041-20000-30677	21550 W OXNARD ST 3rd floor	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 Energy only in existing space Tenant Improveemnt to the Third Floor. Total area: 7862 sq ft. B#16016-40000-24302	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34976	13041-20000-18885	7445 N VARIEL AVE PV-1	91303	3	186B105   456	2112010008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.20587	-118.59301	PV-1. Plan check for microinverters. 12 inverters for 2580W total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34977	16041-10000-17977	430 W 71ST ST	90003	8	102B201   725	6013028022	R2-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.97546	-118.28163	PV 1 roof mounted solar system installation to a single family home. (1) Inverter rated at 3.0 kw. (13) solar modules. (1) load center 125 A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34978	11041-10000-14454	3701 W WILSHIRE BLVD	90010	10	132B193    27	5503029024	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	08/12/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.06188	-118.30708	FIRE ALARM REPLACEMENT SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34979	19041-10000-41150	13075 W VICTORY BLVD	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Closed	01/24/2020 12:00:00 AM	ADDRESS	34.18684	-118.41708	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34980	14041-20000-04861	2917 E 1ST ST	90033	14	126A225    32	5180020031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	34.04084	-118.20294	$0 permit fee is due to the 2012 Senate Bill No. 1222PC FOR PV2 COMMERCIAL ROOFTOP SYSTEM. PLANS HAVE BEEN CHANGED FROM ORIGINAL DRAWINGS. DUE TO NEW SOLAR FEE INCENTIVES AND A REDESIGN IN THE SYSTEM, NEW PLAN CHECK HAS BEEN IMPLIMENTED. TOTAL SYSTEM SIZE 40KW AC USING 4 TRANSFORMED INVERTERS INTERCONNECTED TO EXISTING SERVICE SECTION.((PER BUILDING SUBMITTAL, CODE SHALL BE ENFORCED IN ACCORDANCE TO 2008NEC)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34981	19041-10000-05881	10828 N BALBOA BLVD	91344	12	207B133   174	2683027005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.26686	-118.50205	PV1, ROOF MOUNTED SOLAR SYSTEM USING PV MICRO INVERTERS. (23) MODULES AND (23) ENPHASE IQ7. TOTAL SYSTEM SIZE IS 7.13KWDC /  5.52 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34982	15041-20000-22811	20642-20644 W VENTURA BLVD	91364	3	171B109    75	2166013101	(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.16696	-118.58275	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,924 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34983	14041-20000-28393	14565 W SAYRE ST	91342	7	219B149   564	2507005004	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.29615	-118.45013	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34984	16041-20000-35329	4334 N STERN AVE	91423	2	165B153   402	2271016058	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Issued	10/11/2016 12:00:00 AM	ADDRESS	34.1495	-118.43535	addition of 30 units to accommodate for ac units.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34985	15041-20000-42200	2811 S POTOMAC AVE	90016	10	123B181  1403	5057008008	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.03066	-118.34405	Plan check for PV roof monted system. System size: 3.8kWac with 10 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34986	16041-10000-18894	300 S BROADWAY	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.0508	-118.24797	"FULL PC: CHANGE OF USE FROM (E) RETAIL TO (N) COFFEE SHOP/HOUSE ""BLUE BOTTLE COFFEE""; INTERIOR TI (3,189 SQ) . NEW CONNECTED LOAD > 400A.B# 16016-10000-10917"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34987	16041-30000-44173	4091 S REDWOOD AVE SUITE 101	90066	11	108B153   893	4230006032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	33.99105	-118.44076	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is first time tenant/tenant improvement. Total lighting area = 814 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34988	19041-20000-11993	827 N VINE ST flr 1-3	90038	13	141B185   150	5533030031	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.08598	-118.32689	First-time tenant to (E) 3-story commercial office core and shell.  New distribution, power, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34989	15041-20000-16018	651 W USC MC CARTHY WAY UNIT 3C	90089	9	120A201    78	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	05/26/2015 12:00:00 AM	ADDRESS	34.02135	-118.28288	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CLASSROOMS IN USC THOMAS & DOROTHY LEAVEY LIBRARY. ROOMS 3C. 1093 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34990	17041-20000-07771	700 S NEW HAMPSHIRE AVE	90005	10	132B197   232	5094011018	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Issued	04/05/2017 12:00:00 AM	ADDRESS	34.05951	-118.29274	PV2Install roof-mounted PV system sized 11.4 kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
34991	16041-10000-21846	24105 S FRAMPTON AVE	90710	15	039B197    42	7439011038	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	33.805	-118.29924	PC FOR T24 ENERGY ONLY. LOAD LESS THAN 400A. TOTAL AREA 38000 SQFT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
34992	19041-10000-41130	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.04994	-118.41129	PLAN CHECK TO RELOCATE EXISTING 75KW BACKUP GENERATOR TO SERVE NON CRITICAL LOADS. SCOPE INCLUDES NEW ATS AND 400A PANEL FOR REOCATED BACKUP LOAD IN A PLACE OF ASSEMBLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34993	12041-10000-24174	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.15886	-118.50032	NEW LUMINAIRES IN THE PARKING  ELEVATOR LOBBYS- GRND LEV; B-1 LEV;B-2 LEV; ROOF LEVPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34994	18041-10000-05459	3863 S COOLIDGE AVE	90066	11	114B157  1033	4214013025	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.00755	-118.42279	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.80KWdc / 4.72KWac.(16)MODULES-HANWHA Q CELLS 295W(16)OPTMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
34995	13041-20001-26628	320 E SUNSET AVE	90291	11	109-5A143  83	4286007022	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	33.99526	-118.47456	(((5/6/2014- CHANGES MADE TO APPROVED SET. REVISED SOME CIRCUITS, THIS IS A PLAN CHECK ONLY APPLICATION)))CHANGE OF USE FROM OFFICE TO BAKERY AND RETAIL.   New 800 amp service, new loads, and lighting.  Full Plan Check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34996	10041-10000-01614	11121 W PENDLETON ST	91352	6	198B173    45	2538011010	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM			Corrections Issued	03/12/2010 12:00:00 AM	ADDRESS	34.23852	-118.37336	New 3000 A service for an existing and new shell buildings.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
34997	17041-10000-42002	2421 E 16TH ST	90021	14	118-5A217  86	5168008003	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	34.01978	-118.2294	INSTALLATION OF EXTERIOR LUMINAIRES-5 EA WALL-MOUNTED AND 5 EA POLE-MOUNTED- F0R PARKING LOTPLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34998	15041-20001-41359	800 N HIGHLAND AVE	90038	4	141B185   265	5524004028	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.08547	-118.33839	02/24/2016 Plan check for Title 24 only. Plan check is for a lost set of previously approved plans. Scope of work has remained the same. Total lighting area = 4,595 sq. ft.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO JUST TIRES AUTOSHOP DUE TO FIRE DAMAGE, NO HAZARDOUS LOCATION PER APPLICANT. 4595 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
34999	15041-20001-10030	12465 W OSPREY LANE UNIT 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	33.97923	-118.41018	Expedite per applicat request(((Plan check for PV roof mounted system for tri-plex unit #2 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10020))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35000	15041-10000-26147	8250 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	33.95164	-118.43839	NEW 2000 AMP SERVICE TO POWER MODULAR BLDG WITH 18 PANELS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35001	17041-10000-23953	11979 W WALNUT LANE unit #1	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.03749	-118.4591	Install new rooftop solar system, 2kW AC. (8) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35002	19041-20000-53577	7455 W PALO VISTA DR	90046	4	156B177   379	2427013030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.12314	-118.35732	Plan check for PV roof mounted system, PV system size: 13.69KW with 37 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35003	18041-20001-25796	22624 W CALVERT ST	91367	3	177B097   424	2039017017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.18087	-118.61983	Expedite per applicant request Plan check for PV roof mounted system, system size: 22.08KW with 64 AC Modules connected to theload center 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35004	18041-10000-34750	10201 W PICO BLVD STAGE 17	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Issued	09/18/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	PLAN CHECK FOR TITLE 24 ONLY FOR (E)SOUND STAGE WITH (E)PUBLIC VIEWING AREA - TOTAL AFFECTED AREA = 12800 SF. NO CHANGE OF USE OR RECONFIGURATION OF SOUND STAGEONLY LIGHTING AND EGRESS ILLUMINATION IS INCLUDED AS SCOPE OF WORK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35005	12041-20000-17315	5999 W CENTER DR 4th floor	90045	11	102B169   959	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	33.9761	-118.38876	Remodel of the 4th floor.  Power, energy, and emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35006	13041-20000-28952	1660 E 23RD ST	90011	9	117A213   113	5118021009	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			Reviewed by Supervisor	10/22/2013 12:00:00 AM	ADDRESS	34.01588	-118.24434	PC FOR POWER. NEW 1200A SERVICE. NEW XFORMER AND HOUSE PANELS. NEW SHELL BUILDING FOR FUTURE TENANTS. NON HAZARDOUS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35007	13041-20000-30441	9631 N IRONDALE AVE	91311	12	201B109   260	2748023057	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Info Complete	11/13/2013 12:00:00 AM	ADDRESS	34.24553	-118.58608	Upgrade electrical service to an existing Industrial Building.  Building has two services and two addresses,  9631 & 9621.  Plan check for Power.  ((Variance has been approved for two services to one structure))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35008	12041-20000-27003	9600 N SYLVIA AVE PV 1	91324	12	201B117   546	2762009017	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM			Reviewed by Supervisor	11/19/2012 12:00:00 AM	ADDRESS	34.24478	-118.55174	ROOF MOUNTED PHOTOVOLTAIC SYSTEM  7.5 KW. 3 strings. Zoning done on 12041-2000-26993.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35009	13041-20001-21584	23741 W KILLION ST	91367	3	174B089   597	2047010002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.16999	-118.64505	((EXPEDITE FEES))PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 11.13 KW. 42 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35010	11041-10000-03474	12144 W MAGNOLIA BLVD	91607	5	171B165   567	2356001020	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	34.16471	-118.3981	SINGLE STORY, COMMERCIAL RETAIL BUILDING.  T.I.   FULL PLAN-CHECK.  ADDING 3 PANELS AND NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35011	17041-10000-25202	920 W BLOOM WALK FLRS 1 &4	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.01996	-118.28938	TI TO OFFICE SPACE ON 4TH AND 1ST FLOORS. PC FOR LIGHTING UPGRADES. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35012	13041-20000-33908	10700 W SANTA MONICA BLVD SUITE 207	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.05167	-118.432	T24 FOR EXISTING OFFICE SPACE. SUITE 207	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35013	15041-20000-16880	1156 N AMALFI DR	90272	11	129B133   167	4425012006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.05052	-118.50683	PV1. INSTALLING ROOF MOUNTED. 7.6 AC KW SYSTEM SIZE. (20) SUNPOWER SPR-X21-345(2) SMA SB3800TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35014	15041-20000-38206	5135 N BLUEBELL AVE	91607	2	171B161   655	2357001003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM			Reviewed by Supervisor	11/25/2015 12:00:00 AM	ADDRESS	34.164	-118.41064	PV1, roof mounted solar panel, 11.13kW DC system (42)modules #KU2656ZPA, (1)inverter:#SE10000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35015	16041-30000-06645	2847 1/2 N SIERRA ST	90031	1	141A225   254	5208020004	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Apartment			02/25/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	PIN	34.08007886	-118.20203123	Installation of new roof mounted solar PV system on existing 3 unit apartment (3 meters serving two adjacent buildings).  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35016	19041-20000-03228	8537 N RUBIO AVE	91343	12	192B137    96	2689016005	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.22605	-118.49683	Plan check for  PV roof mounted system, system size: 8.4KW DC with 7.526KW AC with 28 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35017	17041-10000-17627	624 S GRAND AVE 29th flr	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.04802	-118.25572	Tenant improvement at 29th floor of high rise office building. pc for power and energy. data racks and power distribution.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35018	15041-10000-40749	11700 N CORBIN AVE #98	91326	12	216B113     1	2701002068	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.28162	-118.57177	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(TRACT 50509-01_ LOT 99) TWO STORY SFD WITH ATTACH 3 CAR GARAGE_ MODEL DWELLING*STANDARD PLAN # 643 _ PLAN 1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35019	15041-20000-06515	10939 W VENTURA BLVD	91604	2	162B173   393	2366022022	(Q)C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.14033	-118.36859	Title 24 plan check only.  Total area = 1,560 sq. ft.T.I. to existing commercial space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35020	10041-20000-25109	7915 N LINDLEY AVE	91335	3	189B125   476	2102014017	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.21435	-118.5275	Install new subpanels, branch circuits and lighting.  Plan check for power and energy.  A variance for separate fire alarm submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35021	11041-10000-27494	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM	09/05/2012 12:00:00 AM		Permit Finaled	12/11/2012 12:00:00 AM	ADDRESS	34.07594	-118.35916	Plan check for 1.38MW Photovoltaic system. Portion of the modules are on roof and ground mounted canopy installation for parking lot at CBS Studio. Site in Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35022	13041-20000-24822	10712 W VALLEY SPRING LANE	91602	2	165B177   886	2423026001	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.14663	-118.36404	T24 FOR EXISTING THRIFT STORE. SCOPE OF WORK COVERS LIGHTING AND RECEPTACLES. REWIRING TO EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35023	16041-10000-18428	734 S ALAMEDA ST STE #A	90021	14	123A215   225	5166032037	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.03279	-118.2373	PC for T-24 only.  Remove HID fixtures and replace with new LED fixtures. Total atea: 8398 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35024	17041-20000-10242	9130 N FOSTER LANE	91311	12	198B101   336	2727024001		North Valley				1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.23654	-118.60686	PV1.  Install 4.0 kW roof mounted grid tied PV system.  AC module standard plan.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35025	13041-20000-25301	2850 N SIERRA ST	90031	1	141A225   247	5209004003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.08019	-118.20156	PV1 TRANSFORMERLESS INVERTER. TOTAL SYSTEM SIZE 3 KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35026	15041-20001-38656	9107 W SAWYER ST	90035	5	126B169    28	4305028035	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.04537	-118.38831	EXPEDITE PER APPLICANT REQUEST. ((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.0KWac. (42)MODULES-LG LG300N1K-G4(2)INVERTERS-ABB PVI-6000-OUTD-US-A(1) 100A SUBPANEL)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35027	16041-10001-31230	10102 W ANGELO VIEW DR	90210	5	144B153   250	4357014021	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.09356	-118.43392	"Suppl Permit for DELTA ""1"" changes to approved plans for type of service equipment. Siemens 600Amp, 30KAIC , NEMA 3R, series rated with the sub panels.<<<<Plan check for new SFD two story with basement. Service size: 600A>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35028	10041-10000-19063	401 S VERMONT AVE	90020	4	135B197   497	5502009020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	01/05/2011 12:00:00 AM	ADDRESS	34.06699	-118.29189	TI IN AN EXISTING MEAT MARKET. PLAN CHECK IS FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35029	19041-10001-00212	14150 S FIGUEROA ST	90061	15	075B201    42	6132044014	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Issued	06/27/2019 12:00:00 AM	ADDRESS	33.90273	-118.28255	PC FOR POWER ONLY FOR REPLACING AN SERVICE FOR A 600A SERVICE. RECONNECTING EXISTING EQUIPMENT TO NEW SERVICE.note: PC ONLY. PERMIT UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35030	14041-10000-30160	380 WORLD WAY Space T87	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for a T.I  of airport concession space #T87 (Malibu Shades)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35031	16041-10000-34463	6171 W CENTURY BLVD	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM			Corrections Issued	09/28/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	T-24, PC FOR ENERGY ONLY. TI & CHANGE OF USE FROM OFFICE TO RESTAURANT WITH OPEN OUTDOOR DINING AREA. TOTAL AFFECTED AREA IS 1341 SQ. FT. B#16016-10000-20031	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35032	12041-20000-01772	10953 W PENDLETON ST Mez.	91352	2	198B173    20	2538012014	[T][Q]MR1-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.00	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.24078	-118.37027	office t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35033	16041-20000-20190	639 W 32ND ST fire house-studio	90007	9	120A203    49	5123010023	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM			PC Info Complete	06/08/2016 12:00:00 AM	ADDRESS	34.02416	-118.2801	TI to existing commerical building (Fire house studio). Plan check for energy and emergency lighitng only. Adding new lighting new controls to existing panels. total square footage 5108.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35034	12041-20001-25722	15941 W DICKENS ST PV1	91436	5	168B141   674	2283010021	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.15477	-118.48066	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE STORY BUILDING. USING 30 MODULES IN 4 STRINGS AND A TRANSORMERLESS INVERTER. SYSTEM SIZE IS 7.2 KW. [INVERTER: POWER-ONE # AURORA PV1-6000-OUTD-US |||| MODULE: TRINA SOLAR # TSM-240PA05] PERMIT UNDER APP NUMBER 12041-20000-25722	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35035	16041-30000-16355	14708 W VENTURA BLVD 2nd Floor	91403	4	166-5A149  67	2276002020	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.15154	-118.45347	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement/change of use from office to hair salon. Total lighting area = 6,950 sq. ft.Note: Building application has been created under 16016-30000-10197	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35036	15041-20000-09718	7326 N RESEDA BLVD	91335	3	186B125   788	2119019032	[Q]C2-2D-CDO, [Q]P-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.20379	-118.53585	Plan check for pwer and Title-24 (energy).  Total area = 2,474 sq. ft. (indoor) + 22,590 sq. ft. (outdoor)New 1000 A service and electrical distribution system for carwash.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35037	18041-20000-29310	23810 W ALBERS ST	91367	3	171B089    39	2047008018	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.16857	-118.64522	PV1.  Install 10.56 kW roof mounted grid tied PV system.  (32) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35038	17041-10004-31743	6569 W DE LONGPRE AVE	90028	13	147A187   258	5547026041	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM			Corrections Issued	09/18/2018 12:00:00 AM	ADDRESS	34.09624	-118.33278	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE INCLUDES ADDING AC DISCO FOR PV CONDUCTOS PER DWP REQUEST. THIS IS PLANCHECK ONLY![[[6/8/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 3 CHANGES TO RELOCATE INVERTER AND LOAD CENTERS.]]]permitted set of plans are revised to include fused disconnects for energy storage systems and non fused disconnect for inverter output circuit.(((((((((((((** NO FINAL FEES DUE TO SENATE BILL 1222PC FOR NEW PV SYSTEM WITH BATTERY STORAGE. SYSTEM INCLUDES 28 MODULES, CENTRAL INVERTER AND 2 BATTERY UNITS RATED 5.8KW EACH. TOTAL OF 27KWH OF STORAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35039	18041-10000-26484	10277 W OLYMPIC BLVD	90067	5	129B161    44	4319005070	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.05329	-118.41657	Plan check for a fire alarm system replacement. New device also added. Whole system include (1) fire alarm panel, (2) power supply and (29) new fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35040	15041-20000-00764	20004 W PARTHENIA ST	91306	3	195B113   592	2782012010	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	PIN	34.22770499	-118.56903649	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING TOTAL OF 24 MODULES. USES STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35041	13041-10000-35778	475 S 26TH ST	90049	11	126B137    37	4264004013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	PIN	34.04462271	-118.48702462	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STD PLAN. MICROINVERTER. SYSTEM SIZE: 9KW DC.( 36) SOLARWORLD SW 250 MODULES(36) ENHPHASE M215 MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35042	17041-10000-39044	6149 N FULCHER AVE	91606	2	177B173   512	2336033003	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.1826	-118.37331	new rooftop solar system, consist of 16 modules (solarworld Sunmodule Sw 290) and one inverter (SolarEdge technology Se5000H). System Size 5000KWac/4640Kwdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35043	17041-20001-42791	17547 W VENTURA BLVD #105 & 106	91316	5	171B129   351	2257008048	(Q)C4-1VL, (Q)P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.16196	-118.51589	12.13.2017 - Plan check for energy only. TI to beauty salon. New lighting (incl. emergency) - 1,818sqft. Permit fees collected under parent application #17041-20000-42791.=====INSTALL NEW OUTLETS AND CIRCUITS (NOT FOR LIGHTS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35044	14041-10000-09934	408 E WASHINGTON BLVD	90011	9	123A207   252	5127019015	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	PIN	34.02906921	-118.261308	"Permit to be pulled at electrical plan check only.  Plan check is for energy only. Emergency lights installed. <400 amps.Remodel (E)interior at dining room, front counter & beverage bar.  Remodel (E)portion of facade of building. Install parapet at (E)portion of roof.  Install 2'-10"" x 25 & 2'-10"" x 23'-6"" decorative metal trellis canapy.Restripe (E)portion of parking."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35045	14041-20001-13522	13135 MIRA MAR DR	91342		225B165    19	2580018***							Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	PIN	34.31120672	-118.40409465	Modification to approved set's roof plan.  Change in number of junction boxes for wiring transition from modules to conduit.  $0 plan check fee is due to Senate Bill SB-1222. (((PV1.  Install 7 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35046	10041-10000-23340	5755 W 96TH ST	90045	11	093B169   128	4125021024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	12/27/2010 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	33.94955	-118.38214	New manufacture. New panel and circuits. EPC is for power and energy. (Bldg#5755)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35047	11041-10000-00321	6633 N TOPANGA CANYON BLVD	91303	3	180B101   368	2139023027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			PC Info Complete	03/30/2011 12:00:00 AM	ADDRESS	34.19037	-118.60613	Installation of new RTU and split systems for Chase bank	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35048	18041-10000-46792	9835 S WESTERN AVE	90047	8	091-5A193   7	6057010903	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Closed	05/10/2019 12:00:00 AM	ADDRESS	33.94583	-118.30938	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35049	19041-10000-44904	3736 S CRENSHAW BLVD	90016	10	117B185   240	5033001039	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.01875	-118.33468	Plan check for a medical office T.I. Scope includes new lighting and equipment with a total lighting area of 3124-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35050	15041-20001-20074	11672 N MARIPOSA BAY LANE	91326	12	213B117   123	2701028010	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM			PC Approved	07/20/2015 12:00:00 AM	ADDRESS	34.28245	-118.56504	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (3) inverters, (36) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35051	19041-10000-00362	700 S FLOWER ST 10th Floor-Ste 1000	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLAN CHECK FOR TITLE 24 ONLY FOR - Tenant Improvement of (e) office building to add non bearing partitions and suspended ceiling to create office spaces and build out floor. TOTAL AFFECTED AREA = 21100 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35052	12041-10000-00203	633 W 5TH ST 50th fl	90071	9	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM	03/19/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.05099	-118.25468	alterations in officesplan chk is for title 24 and 1 ea	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35053	18041-20000-15263	15260 W VENTURA BLVD Suite 980	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Issued	04/25/2018 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check for energy only in existing commercial office remodel, new lighting existing circuits. Total area: 2,932 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35054	18041-10000-26234	2388 N GLENDALE BLVD A-B	90039	13	148-5A209 434	5440004023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM			PC Info Complete	07/16/2018 12:00:00 AM	ADDRESS	34.09982	-118.25903	PC FOR T-24, ENERGY ONLY FOR A TI TO EXISTING RESTAURANT. SCOPE INCLUDES NEW LIGHTING, CIRCUITS AND RECEPTICALS. TOTAL AFFECTED AREA 340 SQ.FTB# 18016-10000-14404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35055	11041-10000-21204	10000 W PICO BLVD BLDG 3	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00, 2691.00, 2695.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.05211	-118.40654	BLDG. NO. 3 (Men's room section inc. outside lighting) OF POOL HOUSE AT THE HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDGS. NO. 1, 2, 3, & 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35056	13041-20000-20508	5990 N SEPULVEDA BLVD #100	91411	4	177B145   487	2243019023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.17911	-118.46588	Changeto lighting only in an existing 6-story office building.  Load is 60 amps per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35057	13041-20001-31896	12841 N SEAGLASS	90094										Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM				((Expedite))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35058	10041-10000-15615	5630 W MANCHESTER AVE	90045	11	096B169  1118	4125018015	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/10/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	33.95972	-118.37962	TI FOR A RESTAURANT. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35059	17041-10000-00335	248 S MAIN ST	90291	11	111B141   614	4286003020	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Issued	02/01/2017 12:00:00 AM	ADDRESS	33.99669	-118.47804	PC for power only. Upgrading main service of Google Office space from 400 Amps 240/120V 3ph 4W to 800 Amps 240/120V 3ph 4W. New Equipment added. Note: B#15016-10000-28288	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35060	13041-10000-11306	8090 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	33.95166	-118.43325	TEMPORARY CONSTRUCTION SITE. INSTALLATION OF TEMPORARY TRAILERS. SCOPE OF WORK INCLUDES (1) 1200 AMP SERVICE, (3) 300 KVA TRANSFORMERS, AND (3)  1000 AMP SWITCHBOARD. PROJECT LOCATED IN A METHANE ZONE. APLLICANT HAS OBTAINED ADDRESS FROM ADRESSING COUNTER (APN: 4117-036-900)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35061	16041-20000-21867	340 S MAIN ST	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	33.99519	-118.47673	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CAFE AREA IN GOOGLE VENICE. 425 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35062	19041-10002-03775	1623 S CREST DR	90035	5	129B169   687	4305010014	R1V2	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.05011	-118.38764	Expeited Per Customer RequestPC FOR NEW 5.2 KW ROOFTOP PV SYSTEM AND 13.5KW ENERGY STORAGE SYSTEM, SCOPE INCLUDES (1) TESLA POWER WALL BATTERIES, (16) PV MODULES, AND (1) SE5000A INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35063	16041-20000-34361	6420 W WILSHIRE BLVD STE 1100	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for energy only. TI to office #1100 in high rise office building, 4,249sqft. New lighting (incl. emergency) and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35064	12041-10000-06313	1528 W PALOS VERDES DR NORTH BLDG R	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77933	-118.30447	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building R. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35065	17041-10000-35977	7943 N HASKELL AVE	91406	6	189B141    92	2206003020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Issued	10/06/2017 12:00:00 AM	ADDRESS	34.215	-118.47511	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35066	19041-20000-46161	4337 N WOODMAN AVE	91423	4	165B157   483	2271018013	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.14918	-118.43139	T24 PLAN CHECK, REPLACING 3 FLOURESCENT LIGHTS WITH LEDS. TOTAL SQUARE FOOTAGE = 245 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35067	16041-10000-35862	200 N FALCON ST	90744	15	021B205    25	7440019908	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	33.75579	-118.2664	PC for power only. Scope of work includes new equipment  (VCU X01) and 4 new circuits in panel DP-644. Equipment is located in hazardaus location Class 1 Div 2. Note delta 8.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35068	15041-10000-43172	3221 W TEMPLE ST	90026	13	139-5A201 222	5156007015	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village		1958.02	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.07565	-118.28154	PC for energy only, T-24. Tenant improvement to a commercial site (drink houz). Adding new lighting and power. Total sq ft = 710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35069	17041-10000-26054	21415 W PLUMMER ST 2ND FLR	91311	12	201B105   244	2746015022	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.24287	-118.59861	TITLE 24 PLAN CHECK FOR TENANT IMPROVEMENT (COMMERCIAL OFFICE) FOR LOW RISE BUILDING. TOTAL AFFECTED AREA 1425 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35070	17041-20000-31645	9665 N DALE AVE	91040	7	201B177   387	2544004011	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.24506	-118.357	PV1.  Install 9.625 DC kW roof mounted grid tied system.  (35) modules with (2) string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35071	16041-20000-24909	8806 N CANBY AVE	91325	12	195B125   563	2769026002	R2-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.23101	-118.53467	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.27 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35072	16041-10000-02089	17219 W MIDWOOD DR	91344	12	216B133   463	2606014018	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.28662	-118.50865	PV1, Install 12.455 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (2) INVERTER:  ABB PVI-4.2 & 6000-OUTD-S-US-Z-A.  (47) Modules: KYOCERA  KU2656ZPA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35073	17041-20000-34274	21133 W COSTANSO ST	91364	3	171B105   284	2167002024	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.16639	-118.59434	Plan check for power and energy. TI/Change of use from dance studio to medical office. New lighting (incl. emergency) - 1,930sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35074	13041-10001-36002	523 W 7TH ST	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.04717	-118.25611	CHANGES TO APPROVED (plan check only): TO INSTALL LISTED PANEL P400  (FACP-2). Potter P400 to serve the SAVOR tenant Restaurant. Shall be connected to building's main FACP-1 located in the basement. This new FACP-2 shall be interfaced with the building's main FACP-1 as an alarm zone via relay and module. New notofication appliances to be connected to  P400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35075	18041-10000-40811	12444 W VICTORY BLVD	91606	2	180B165   731	2333007042	[Q]C2-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.18645	-118.40454	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35076	13041-10001-29580	1563 W 218TH ST	90501	15	048B193    57	7346002038	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	33.83038	-118.30596	Expedited RSES plan check per applicant request. PV1.  Install 10.78 kW DC roof-mounted solar array, interconnect with main service panel.   Inverter: Fronius IG Plus V 7.5.  44 modules: Yingli Yl245P-29b.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35077	13041-20000-29864	630 W 28TH ST 1-9	90007	9	121-5A203 146	5123014401	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.02634	-118.27859	FIRE ALARM FOR 9 UNIT APARTMENT. TOTAL OF 70 DEVICES AND 2 PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35078	12041-10000-04865	1025 W 34TH ST KOH	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	08/03/2012 12:00:00 AM	PIN	34.02400284	-118.2895744	PLAN CHECK POWER AND ENERGY FOR REMODEL OF EXISTING DINING HALL, FOODCOURT AND KITCHEN, SERVING ADJACENT RESIDENCE HALL/DORMITORY BLDGS AT USC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35079	12041-20000-02639	12719 W SAN VICENTE BLVD	90049	11	129B141   373	4405024006	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2012 12:00:00 AM			PC Info Complete	09/06/2012 12:00:00 AM	ADDRESS	34.05023	-118.4837	Accsessory buildiing for poor area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35080	19041-10001-20240	1273 N TOWER GROVE DR	90210	5	144B157   135	4356026019	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM			PC Approved	06/14/2019 12:00:00 AM	ADDRESS	34.09358	-118.42434	Expedite per applicant request.PV Tile-System: Plan check for a 10.9KW DC / 9.0KW AC PV1 roofmounted system with with (5) strings, and (2) energy storage system interconnecting through the load center covering a total roof of  763-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35081	14041-10000-10259	11224 W MORRISON ST	91601	2	168B173    18	2353016005	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			04/18/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.16065	-118.37532	NEW 4 STORY 8 UNIT APARTMENT BUILDING. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35082	14041-10002-07234	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	33.98173	-118.4029	03/18/2016CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE ADDITION OF 33 SENSORS AND 1 STROBE. (((CHANGES TO PERMITTED SET OF PLANS- ADDITION OF 2 METHANE SENSORS  AS USE OF BUILDIN 1 CHANGED (METHANE MITIGATION PLANS. BUILDING 2 OF 2. ELECTRICAL PLANCHECK  APPLICATION # 13041-10000-35618	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35083	18041-20000-36926	1829 S MESA ST LOT 6	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.72731	-118.28593	Plan check for PV roof mounted system, system size: 3.02KW with 9AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35084	14041-20001-09011	18325 W LINNET ST	91356	3	171B125   326	2161022027	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.16583	-118.53247	Expedited plan check per applicant request.  (((PV1.  Install 4.25 kW roof-moutned PV system, interconnect with main service panel.  Transformerless inverter w/ power optimizers: SolarEdge SE3800A-US-ZB-U.  17 modules: Canadian Solar CS6P-250PX.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35085	18041-10002-35431	12710 W ADMIRAL AVE	90066	11	105B157   140	4223021020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			PC Info Complete	02/26/2019 12:00:00 AM	ADDRESS	33.98721	-118.42623	"DELTA ""B.1"" CHANGES TO THE APPROVED PLANS FOR RELOCATING THE PV EQUIPMENT TO THE OTHER SIDE OF THE BULDING.<<<PV1.  Install 7.250 kW DC roof mounted grid tied PV system with energy storage system.  (25) modules with 7.6 kW rated string inverter.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35086	17041-20000-39367	20968 W AVENUE SAN LUIS	91364	3	171B109   154	2167020024	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.16494	-118.59047	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (42) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35087	16041-20000-25288	15150 W ROXFORD ST	91342	7	228B145   441	2502004038	C1-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.31841	-118.46333	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 15.2 KW, INTERCONNECT WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35088	16041-10000-28393	3211 S LA CIENEGA BLVD	90016	10	123B173  1686	4205035008	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.02942	-118.37217	Full plan check for existing office 2 story building. Scope is divided into two different phases. Phase 1 as noted in plans include indoor title 24, installing lighting and power for a total sqft of 18,705. In phase 2 the service is being upgraded to 1600 amps plus installing outdoor lighting for a total outdoor area of 28173 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35089	18041-10000-03783	22846 W VENTURA BLVD	91364	3	171B097   554	2042005062	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.16531	-118.62473	PC FOR TITLE 24 ENERGY ONLY FOR A NEW AUTOMOBILE RENTAL AND SALES (WITH CARWASH).SCOPE INCLUDES NEW SERVICE 400A 120/240 3PH  TOTAL CONNECTED LOAD <400AALSO INCLUDES NEW PANELS,  CIRCUITS,  EQUIPMNET AND  LIGHTING FOR INDOOR AND OUTDOOR.   TOTAL AFFECTED AREA 19285 SQ. FT (INDOOR AND OUTDOOR)B#16010-20000-05013	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35090	18041-10000-02520	2624 S KERCKHOFF AVE	90731	15	009B197   853	7465013028	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Expired	03/20/2020 12:00:00 AM	ADDRESS	33.72009	-118.28961	PC FRO ROOF MOUNTED PV ON SFD. SCOPE INCULDES 12 MODULES WITH OPTIMIZERS AND SINGLE INVERTER. SYSTEM SIZE  3.8KWDC 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35091	14041-20000-04725	1680 N VINE ST STE #E706	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	T24 PART 6 ENERGY FOR HIGH RISE BUILDING. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING SCOPE OF WORK 1468 SQ FT. REQUEST FOR MODIFICATION OF BUILDING ORDINANCES FILED ON AUGUST 1, 2013 TO UTILIZE 90 MINS BATTERY SECONDARY POWER SOURCE FOR LIGHT FIXTURES TO EXIT TENANT SPACES INTO MAIN EGRESS PATH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35092	13041-10000-22475	6921 S LA TIJERA		11	102B173   156	4103003015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			Reviewed by Supervisor	08/26/2013 12:00:00 AM	PIN	33.97596126	-118.37406019	PC FOR POWER AND ENERGY. TI TO (E) RETAIL.  99c STORE FULL TENANT IMPROVEMENT. all eqmpt is new per applicant. not a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35093	11041-20000-26231	6320 N CANOGA AVE Ste # 650	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	ADDRESS	34.18499	-118.59722	T.I in suite # 650.  Relocating and adding new light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35094	13041-10001-35723	1186-1188 E 43RD PL # 1186	90011	9	114A209   376	5115034014	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.00466	-118.25446	Expedited RSES plan check per applicant request.{{PV1, Install 2.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (10) modules Trina Solar TSM-250PA05.18.One of two systems on the same building from range 1186 to 1188 43rd pl.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35095	11041-20000-10553	14724 W VENTURA BLVD 300	91403	5	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	06/28/2011 12:00:00 AM	ADDRESS	34.15162	-118.45395	PLAN CHECK T24 ENERGY LIGHTING AND EMERGENCY FOR REMODEL TO OFFICE ON THE THIRD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35096	14041-10000-24554	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM			PC Info Complete	09/16/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	ON LEVEL 2 AND 3 , REPLACING BAGGAGE CONVEYORS AND RELOCATING PANELBORDS THAT ONCE SUPPLID THE OLD CONVEYORS; CHANGES TO LIGHTING SYSTEM IN THE ROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35097	15041-10001-36118	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	ADDRESS	34.24205	-118.59773	EXPPEDITED FEES (((PV2, ROOF MOUNTED SYSTEM TOTAL SIZE 705.87 KW-DC, 624KW-AC. (2139) MODULES, (26) INVERTERS AND (3) LOAD CENTERS. (2139) SUNIVA OPT 330-72-4-100(26) SMA AMERICA STP-24000TL-US-10)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35098	16041-30000-31130	1416 S LA BREA AVE	90019	10	129B181  1038	5070019051	C2-1-O	Central	Wilshire			2172.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.04726	-118.34465	Plan check Title 24 only in existing space T.I.,  remove outdoor HID lighting fixtures and replace with new LED lighting fixtures. Total area: 8,600 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35099	18041-20000-18096	820 S LA BREA AVE	90036	4	132B181   315	5084003047	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Issued	05/15/2018 12:00:00 AM	ADDRESS	34.06001	-118.34466	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 792 sq. ft.Note: Building permit has been issued under 18016-10000-13919	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35100	08041-10001-10705	3580 W 3RD ST	90020	4	135B197   227	5502007002	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	ADDRESS	34.06889	-118.29371	immense changes to approved set of plans- revised the single line diagram to show that the service swbd having a feeder to a panel in the building at 3580 w 3rd st and a feeder to another panel (will be installed by the tenant) in the building at 3566 w 3rd stCHANGE OF USE FROM AUTO REPAIR TO STANDARD RETAIL, INCLUDING A NEW SERVICE AND DISTRIBUTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35101	17041-10000-15288	9560 N TOPANGA CANYON BLVD	91311	12	201B101   490	2746018009	(Q)MR1-1, QMR1-1, [T][Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24402	-118.60657	PC for energy only, Outdoor Title 24. Removing HID fixtures and replacing them with new LED fixtures. Total area: 41,375 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35102	13041-10000-36086	10201 W PICO BLVD BLDG 101	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Issued	04/28/2014 12:00:00 AM	PIN	34.05182951	-118.41257696	TI TO TECHNICAL OPERATIONS CENTER; PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 10,077 SQ FT AREA(INDOOR). NEW CKTS + PANELBOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35103	10041-10000-25320	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM			PC Info Complete	04/08/2011 12:00:00 AM	ADDRESS	33.9451	-118.37436	New retail store inside the hotel. EPC is for T24 & emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35104	11041-10000-22802	22120 W CLARENDON ST	91367	3	174B101   480	2169026106	(Q)CR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.16947	-118.6089	T.I. to an existing office building.  Plan check for POWER and ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35105	15041-20000-40198	6260 N TOPANGA CANYON BLVD Parking	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.18497	-118.60418	0$ permit fees due to senate bill 1222Plan check for a PV2 roof-mounted PV system. System size 532 kWac and consists of (19) inverters, (5) load center, and (2166) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.Note: Building plans have been submitted under 15016-20000-26338	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35106	17041-10000-19475	6130 S AVALON BLVD	90003	9	105B205   683	6007009025	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	33.98365	-118.26499	"PC FOR TI, POWER AND ENERGY FOR ""LA FOOD PREP""SCOPE INCLUDES NEW SERVICE 2500A 480/277VINSTALLING NEW EQUIPMENT CIRCUITS AND LIGHTING TOATL AFFECTED AREA 58558 SQ.FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35107	15041-10001-36185	4830 N STROHM AVE	91601	4	168B177   392	2420005005	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	ADDRESS	34.15858	-118.3592	"12/03/15CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1. CHANGES INCLUDE THE RELOCATION OF THE INVERTER AND REDUCTION OF EMT CONDUITTO 3/4"" FROM INVERTER TO THE MAIN PANEL. FEES ARE $0 DUE TO SENATE BILL 1222. (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.(33) SOLAR WORLD SW280 MODULES(33) P300 OPTIMIZERS(1) SOLAREDGE SE10000 INVERTER)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35108	15041-20000-36484	2225 W SUNSET BLVD	90026	13	139-5A207  19	5402031004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1956.00	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			Reviewed by Supervisor	02/12/2016 12:00:00 AM	ADDRESS	34.0781	-118.26596	Plan check for power and energy. Project site is a new 5-story mixed use building: 3 levels of residential over 2 levels of retail, with 2 levels of underground parking garage. Total indoor lighting area = 10,185 sq. ft. and total outdoor lighting area = 818 sq. ft. Note: Plan check is for (2) building, both of which have been included in (1) set of plans. Both building area being fed from (1) LADWP service. Other building can be found under application 15041-20000-43192.FIRE ALARM VARIANCE NOT YET FILEDNote: Building application has been generated under 15010-30000-03157	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35109	18041-30000-12307	1633 W 11TH ST	90015	1	129A203   162	5137016012	C1-1-HPOZ	Central	Westlake	Pico Union		2095.20	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.04818	-118.27573	Plan check for a fire alarm system for a charter school. Fire alarm system consists of (1) FACP, (1) RPS, and (128) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35110	16041-10001-14573	12919 W VICTORY BLVD	91606	2	180B161  1034	2326016018	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.18684	-118.41451	08/03/16Changes to an approved set of plans. Changes include adding outdoor title 24 and replacing/adding indoor lighting fixtures. New total affected area is 5938  SQ. ft. ((((T-24, PC FOR ENERGY ONLY. TI TO AN (E) RESTAURANT (MCDONALDS RESTAURANT). SCOPE INCLUDES REPLACING FLOURESCENT FIXTURES WITH LEDs. TOTAL AFFECTED AREA IS 2023 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35111	11041-10001-25245	3124 N NICADA DR	90077	5	159B149   369	4379035192	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2011 12:00:00 AM			PC Approved	12/21/2011 12:00:00 AM	ADDRESS	34.13054	-118.44877	Delta 1 revision to approved plans. Remove new subpanel from scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35112	17041-10000-44898	360 E 2ND ST 358	90012	14	130-5A213  21	5149009067	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC for T24 only. Installing new two new panels, lights, receptacles and equipment. Total area is 2457sqft. 17016-30000-34239	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35113	18041-20000-45638	17044 W JERSEY ST	91344	12	207B133   105	2696021018	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.26751	-118.50382	Plan check for a PV1 roof-mounted PV system. System size is 8.12 kWdc/7.6 kWac and consists of (1) inverter and (28) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35114	14041-10001-24475	9912 N MARNICE AVE	91042	7	201B205   400	2571016063	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.24743	-118.27179	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 5.255 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(21) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): ABB PV1-4.2-OUTD-S-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35115	17041-20000-46480	10936 N SHARP AVE	91345	7	210B149  1139	2615028020	RA-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.26862	-118.44755	Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.7.6kW ungrounded pv system. (29) 325W pv modules. (29) 400W power optimizers.(2) 5kW Tesla Powerwall 2s.$17.93 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35116	16041-10000-30456	7900 N CLYBOURN AVE #B	91352	2	189B177   369	2466031026	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.21401	-118.36386	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.TOTAL AREA (INDOOR) 8150 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35117	18041-20000-02482	601 W 5TH ST 5th Floor	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Title 24 only. Project site are the common areas on the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,002 sq. ft.Note: Building application has been generated under 17016-10000-31370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35118	15041-20000-07260	19540 W LORNE ST	91335	3	189B117   228	2105004009	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.21667	-118.55957	Plan check for PV 1 roof mounted system 5kW inverter and 19 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35119	18041-10002-15377	17950 W PARTHENIA ST	91325	12	195B129   429	2787001019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.22845	-118.52472	INSTALL A NEW 17KW PV SYSTEM WITH 54 MODULES AND BACKUP BATTERIES ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35120	17041-10000-43846	555 S FLOWER ST C LEVEL	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/30/2022 12:00:00 AM	ADDRESS	34.05048	-118.25755	PLAN CHECK FOR INSTALLATION OF NEW EMERGENCY GENERATOR IN EXISTING HIGH RISE BUILDING - ALL DISTRIBUTION EQUIPMENT REMAINS THE SAME. GENERATOR SIZE = 1000KWENGINEER STAMP MISSING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35121	13041-20000-18321	18425 W KITTRIDGE ST 1-77	91335	3	180B125   375	2125015003	(T)(Q)R3-1LD	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.19033	-118.53458	FIRE ALARM SYSTEM FOR MULTI FAMILY DWELLING. TOTAL OF 419 DEVICES AND 7 PANELS. PER APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35122	14041-20000-22021	13834 N LEXICON AVE	91342	7	228B157   265	2503014008	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.32371	-118.42834	PV1Central/String inverter standard plan.Install roof-mounted solar arrayon on SFD, interconnect w/MSP. System size: 6kW.(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(28) Trina Solar #TSM-255PA05.18 pv modules(28) Solar Edge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35123	19041-10000-50727	15106 W OXNARD ST	91411	4	177B145   479	2243020025	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.17914	-118.46205	T-24, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES REPLACEMENT OF OUTDOOR FIXTURES TO LED. TOTAL S. FT. 49600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35124	18041-20000-37926	11677 W SAN VICENTE BLVD 109	90049	11	132B145   497	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.05404	-118.46492	Change of use from retail/office to personal service studio.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35125	13041-20000-12695	444 E 92ND ST	90003	9	094-5A207 254	6052025004	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	33.95275	-118.26577	pv2 apartment((plan check for permit already issued. original permit # 13041-20000-11256INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 2.89 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35126	18041-10001-45079	11954 W WASHINGTON PL	90066	11	111B157   367	4233016017	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.00202	-118.42492	Changes to an approved set of plans, changes include addition of controlled receptacles, day light sensors and fixture layout. T-24 PLAN CHECK ONLY TO A TI OF AN OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUITS. TOTAL SQ. FT. 2808	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35127	16041-20001-29454	8115 N LANKERSHIM BLVD	91605	6	189B169    47	2310007012	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM			PC Approved	10/18/2016 12:00:00 AM	ADDRESS	34.218	-118.38798	"10/18/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes include change of services for the distribution equipment being installed.*****Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. Change of use from warehouse to manufacturing and interior ti for ""Granda hills discount pharmacy """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35128	19041-10000-23462	9145 N WINNETKA AVE Bldg 1	91311	12	198B113   212	2748039030	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			Corrections Issued	02/04/2020 12:00:00 AM	PIN	34.2368297	-118.57294016	Full plan check for a new Industrial Warehouse Building core and shell (Building 1).Scope includes new 1000a service. Total affected area 250,743 sq.ft including the outdoor lighting for the full lot. 1 of 3B#19010-10000-01394	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35129	19041-10000-34087	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.23541	-118.47521	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35130	12041-20000-24944	1408 S WESTWOOD BLVD	90024	5	132B153   863	4325019018	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM			PC Info Complete	05/21/2013 12:00:00 AM	ADDRESS	34.05512	-118.44136	800A SERVICE UPGRADE. MIXED USE (COMMERCIAL AND APT). CIRCUITS AND SUBPANELS TO REMAIN EXISTING.  Location is in Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35131	19041-20000-46113	13346 W SATICOY ST	91605	2	186B157   202	2303028013	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	02/14/2020 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.20798	-118.42412	Plan check for power and energy for 600A Equipment, lighting and assocated load. Total area: 5822 sq ft. ******************************************Building work description: 19016-20000-36232CHANGE OF USE FROM MANUFACTURING TO NEW LEASABLE KITCHENS***********************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35132	13041-10000-21973	518 N PALISADES DR #518	90272	11	129B117   107	4419015025	(Q)C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/14/2013 12:00:00 AM	ADDRESS	34.04489	-118.55177	TENANT IMPROVEMENT FOR EXISTING RETAIL STORE, TO BE REMODEL (EXPANSION). TITLE-24 PLAN CHECK-ONLY IN A SINGLE STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35133	19041-20000-04037	1455 N DONHILL DR	90210	5	147B161   197	4355015058	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.09802	-118.4167	PV1.  Install 15.180 kW DC / 11.4 kW AC roof mounted grid tied PV system.  (46) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35134	13041-20001-28897	16454 W KNOLLWOOD DR	91344	12	219B137    75	2609016004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/19/2013 12:00:00 AM	ADDRESS	34.29655	-118.49563	(((Expedite fees only)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 11.73. 46 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35135	17041-20000-16758	700 S FLOWER ST SUITE 860	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 4901 SQFT. SUITE 860	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35136	17041-10000-40935	530 W 6TH ST	90014	14	129A209    78	5144004012	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.04853	-118.25518	Installing a vertical 340 ft 1600A  busduct on an existing switchboard ; busduct terminates on a new 1600A distribution board which will refeed  600AT and  800AT panelboards with existing loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35137	18041-20002-39536	8550 W WENTWORTH ST	91040	7	207B189   169	2555003002	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.26677	-118.31971	$0 PERMIT FEES DUE TO SB1222, AB1414PLAN CHECK ONLY SUPPLEMENTAL, FOR APPROVED SET OF PLANS*original*Plan check for PV roof mounted with Energy storage system, PV system size: 4.575kW with 15 PV Modules and 1 inverter(3.8kw) and 1 Tesla Battery 2.0 13.5kWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35138	13041-20000-18247	1440 W 19TH ST	90732	15	012B193   820	7460009013	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2970.00, 2973.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	33.72715	-118.30886	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.56 KW USING 6 MODULES. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35139	13041-10000-36019	18770 W HILLSBORO ROAD	91326	12	207B121   482	2728029028	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.2637	-118.54196	$0 Permit fee is due to the 2012 senate bill # 1222.PV1, Install 13.5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 5000A-US and Solaredge SE 6000A-US. (54) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35140	19041-20000-44919	17317 W SATICOY ST	91325	12	186B133   178	2202009008	C2-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.20855	-118.51049	Plan check for title 24 energy only, new lighting. Total area: 2799 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35141	15041-20000-28733	3003 W LEEWARD AVE 1-67	90005	1	132B197   281	5077017021	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Issued	10/22/2015 12:00:00 AM	ADDRESS	34.05885	-118.28935	$0.00 Fee due to CA Senate Bill 1222.    PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 90KW(291) CANADIAN SOLAR CS6XMODULES(3) SMA 24000TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35142	16041-10000-01550	3705 W SUNSET BLVD	90026	13	144A203    12	5429021027	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.09079	-118.27782	NEW FIRE ALARM SYSTEM 25 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35143	14041-20000-27614	5264 N TUJUNGA AVE	91601	2	171B173   356	2350017010	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.16663	-118.37881	TI to (E) 323 sq. ft. commercial retail space.  Plan check for changes to lighting system under Title 24 Part 6.  New lights in pick-up area, all others existing per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35144	14041-10000-06619	8323 N DE CELIS PL	91343	12	192B137   289	2689011027	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.22175	-118.49608	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 28090 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35145	16041-20001-41689	5242 E NEWTONIA DR	90032	14	147A237   298	5309006015	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Expired	09/15/2023 12:00:00 AM	ADDRESS	34.09625	-118.16582	Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35146	17041-20000-12353	3000 S ROBERTSON BLVD ste 245	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	ti to an existing commercial office suite 245.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 4232.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35147	17041-10000-09753	115 W 25TH ST	90007	9	121-5A205 183	5126035012	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.02624	-118.26865	PC for Energy only, T-24. Interior TI for Fire Damage (Wein Products) New Lighting and power. New panels, and equipment. New added load is less than 400 amps.  Area: 3685.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35148	17041-10000-01663	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			Corrections Issued	02/17/2017 12:00:00 AM	ADDRESS	34.25052	-118.51258	PC FOR PV SYSTEM 10KW AC USING CENTRA INVERTER. USING POWER OPTIMIZERS. TOTAL OF 43 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35149	17041-10000-01334	1331 N CAHUENGA BLVD	90028	13	147A187   323	5546017014	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM			PC Info Complete	08/11/2017 12:00:00 AM	ADDRESS	34.09556	-118.32924	Plan check for new fire alarm system 7 storymixed use apartment building with 3 levels of basement:  5 story apartment building over  2 stories , 369 appartment units,building # 16010-10000-03279	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35150	17041-20000-46290	6150 N LAUREL CANYON BLVD BLDG J	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	Remodel of (E) commercial retail building.  New 34.5 kV service feeding medium voltage loop power distribution system for surroundibg open air mall.  Building permit under 16016-10000-30409.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35151	13041-10001-22281	20306 W CORALINE CIR	91311	12	207B113   142	2707018012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.2629	-118.57598	EXPEDITED PLAN CHECK PER APPLICANT REQUEST.(((PV1.  INSTALL 12.25 KW DC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN SERVICE PANEL.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35152	18041-30000-33747	9016 W THRASHER AVE	90069	4	147B169   737	5560004011	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM			PC Info Complete	11/16/2018 12:00:00 AM	ADDRESS	34.09755	-118.38672	Plan check for Power only on a new one story single family dwelling with basement and attached garage. New 800A, 120/240V, 1ph service, (10) new panelboards, (1) 30 kW Generator, (1) 10 kVA steam generator, (2) elevators, and (2) EVCS  **This is plan check only, permit is covered under Building Combo Permit # 16010-30000-00165**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35153	12041-20000-22974	22816 W VANOWEN ST	91307	3	180B097    43	2038040028	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.19345	-118.6243	T-24 lighting plan check for remodeled restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35154	11041-10000-06441	445 S FIGUEROA ST FLRS 2-39	90071	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00, 2077.10	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	08/26/2011 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.05295	-118.25675	INSTALL A CENTRAL UPS SYSTEM FOR EXISTING TELEPHONE EQUIPMENT.  HIGH RISE BUILDING.  FLOORS 2-39	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35155	14041-20000-06275	12609 W JUDD ST	91331	7	213B161   460	2532018019	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.28078	-118.40804	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35156	13041-10000-03772	4747 N COLLIS AVE	90032	14	148-5A233  65	5301025022	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	2011.10, 2013.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	34.10103	-118.17854	Microinverter Standard Plan. PV1 FOR 2-story SINGLE FAMILY DWELLING.  5.46 KW DC. 21 MODULES {MODULE: AUO GREENTRIPLEX PM260M00}  MICROINVERTERS {ENPHASE M215-60-2LL-S22/S23 MICROINVERTER 215W} Zoning Clearance Through Application number 13041-10000-03772.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35157	16041-10000-10842	1308 W 65TH ST	90044	8	105B197  1498	6014008013	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	33.98052	-118.29843	PV1, INSTALL 2.6 KWdc / 2.4 KWac ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. STANDARD PLAN IS BEING USED.  (10) MODULES: CANADIAN SOLAR CS6P-260P(10) MICRO INVETERS: ENPHASE M250-60-2LL-S22-240	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35158	18041-10000-38342	6050 S WESTERN AVE	90047	8	105B193   572	6002023019	[Q]CM-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	33.98482	-118.30878	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35159	15041-20000-06617	16129 W LEADWELL ST	91406	6	186B141   606	2205025007	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.20401	-118.48463	PC FOR POWER ONLY. 600A SERVICE. NEW PANELS FOR CORE AND SHELL ONLY. NO LOADS UNDER THIS APPLICATION. ALL LOADS SHALL BE INSTALLED PER NEW T24 REQUIREMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35160	17041-20000-19286	4645 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.04717	-118.3388	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR WORLD OF WHEELS ROLLER RINK. 20,399 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35161	19041-10000-21732	831 W 37TH ST SHS BLD-2ND FLR	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Closed	10/29/2019 12:00:00 AM	ADDRESS	34.01971	-118.28749	ENERGY PLAN CHECK FOR AN OFFICE TENANT IMPROVEMENTS LOCATED ON THE 2ND FLOOR OF SHS BUILDING. SCOPE INLCUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 940-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35162	14041-20001-21099	19801 W LINNET ST	91364	3	171B117   112	2164002019	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM			PC Approved	08/12/2014 12:00:00 AM	ADDRESS	34.16756	-118.56366	Expedited plan check for rooftop solar.PV1.  Install 9.36 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35163	11041-10000-08729	614 S ST ANDREWS PL	90005	10	135B193   930	5503032008	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Apartment			11/01/2011 12:00:00 AM			PC Info Complete	04/18/2012 12:00:00 AM	ADDRESS	34.06286	-118.3114	APRTMENT BUILDING FIRE DAMAGE REPAIR.  FULL PLAN CHECK. 59 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35164	12041-20000-19943	12151 N SAN FERNANDO ROAD	91342	7	216B149   236	2611010005	C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.29057	-118.44992	NEW 800A SERVICE AND NEW SWITCHBOARD FOR NEW MEDICAL BUILDING. PLAN CHECK FOR POWER AND ENERGY.  AMBULATORY HEMODIALYSIS CLINIC, SUBJECT TO OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35165	17041-10000-12293	730 E 9TH ST	90021	14	124-5A211  73	5132001048	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Public Safety Only			04/14/2017 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.03646	-118.24965	PC for power only on existing 2 story wherehouse building. Service upgrade. New service rated at 800 Amps 120/240V 3ph 4W. Existing loads to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35166	14041-10000-28536	6801 W HOLLYWOOD BLVD SUITE 127	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	"Title 24 plan check only. Area = 461 sq. ft. Installating of two new panelboards and luminaires.Building permit: 14016-10000-20704.INVESTIGATION FEE Paid.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater. ""COMPLY WITH DEPARTMENT ORDER effective date08/20/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation. Ifadditional assistance is needed, please call Inspector GARY LYNCHat (213)252-3089 of ON-SITE SIGN ENFORCEMENT.  CEIS Case Numberis 579382.(Created: IMSV7 / 08-14-14)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~***END PRINT: 331285 (12/15/14 12:36)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35167	17041-10000-25077	5600 W CENTURY BLVD	90045	11	090B169    36	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	33.94469	-118.37969	PLAN CHECK FOR T24 ONLY FOR (OFFICE PARTITION,  RENOVATION OF HIGH BAY DOCKS). PLAN CHECK ONLY INCLUDES CONDITIONED SPACE. TOTAL AFFECTED AREA 393 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35168	13041-20000-27854	6723 W FOOTHILL BLVD	91042	7	202-5A203 416	2570017019	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.24751	-118.2787	Change to outdoor lighting in an existing restaurant.  Load is less than 400 amps, per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35169	14041-10000-19915	707 W WILSHIRE BLVD 1st floor	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	plan check for energy only. emergency lighting installed in a high rise building. Installing new panel 1D. TI TO (E) WELLS FARGO with 2013 T24 standards. BLDG#14016-10-13892 (see additional comments)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35170	18041-30001-01541	10007 S CENTRAL AVE	90002	8	090B209   216	6049028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Approved	04/12/2018 12:00:00 AM	ADDRESS	33.94544	-118.25433	04/12/2018 Changes to an approved set of plan. Changes have been made to the single-line diagram and the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms. *****Previous Work Description*****Plan check for Title 24 only in existing space. Total area: 1,867 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35171	19041-20001-06378	17138 W SESNON BLVD	91344	12	225B133   214	2602003025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM			PC Approved	03/08/2019 12:00:00 AM	ADDRESS	34.30995	-118.50644	Expedited plan check submittal.  PV1.  Install 8.64 kW roof mounted grid tied PV system with 9.8 kWh energy storage system.  (27) modules with 7.6 and 3.8 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35172	13041-20000-24136	5835 W COMPASS DR	90045	11	099B169   428	4105010007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	33.96871	-118.3843	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.75 KW. 15 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35173	11041-10000-25202	2459 E 8TH ST	90021	14	123A217   299	5166006014	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	03/19/2012 12:00:00 AM	ADDRESS	34.02971	-118.22802	PLAN CHECK T24 ENERGY FOR WAREHOUSE/OFFICE & MANUFACTURING BUILDING. PERMIT FOR NEW BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35174	13041-20000-35678	21900 W STANWELL ST	91311	12	207B101   186	2722033032	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.2619	-118.60458	PV1 MICROINVERTER STANDARD PLAN 5KWAC. 24 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35175	16041-10000-02664	1473 W 47TH ST	90062	8	111B193   542	5016012023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Expired	02/22/2018 12:00:00 AM	ADDRESS	34.00113	-118.30267	PV1, rooftop solar system 3.6 kW AC (17) KU2656ZPA (1) PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35176	12041-20000-16718	12840 W RIVERSIDE DR # 312	91604	2	168B161   459	2357033012	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	PIN	34.15731555	-118.4128018	T.I. to existing medical office on the 3rd floor, suite 312.  Install branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35177	11041-10000-00424	1875 CENTURY PARK EAST # 1025	90067										Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM			PC Approved	01/10/2011 12:00:00 AM				ALTERATIONS IN EXISTING OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35178	10041-10004-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	02/04/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	single line diagrams with existing switchboards and distribution boards supplying tenant panel boards at the North and South Concourses Concessions. Review was requested such that approved plans will be on site as tenants are now moving into and modifyiny their tenant spaces. These show the tenant design loads and any modification from the design loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35179	14041-20000-21783	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.21328	-118.45279	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.PV2 COMMERCIAL ROOFTOP. PLAN CHECK FOR FOR ROOF MOUNTED PV IN 2 LOCATIONS. ONE ON EXISTING BUILDING AND ANOTHER ON NEW PARKING CANOPY. ALL FALLS UNDER SAME PV SYSTEM. TOTAL SYSTEM SIZE 600KW AC USING 6 CENTRAL INVERTERS. TOTAL 664KW DC. CONNECTION TO 480V 1000A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35180	14041-20000-05854	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM			PC Info Complete	03/04/2014 12:00:00 AM	ADDRESS	33.97902	-118.43558	T24 FOR EXISTING OFFICE BUILDING. SCOPE OF WORK ON STAIRS LEADING TO THE ROOF, OUTDOORS, AND MAIN LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35181	18041-10000-39635	5401 S VERMONT AVE	90037	9	108B197   643	5002023032	C2-1L	South Los Angeles	South Los Angeles	Voices		2326.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.99305	-118.2918	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35182	16041-20000-34173	11119 W VENTURA BLVD	91604	2	162B173   307	2366024006	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM			PC Info Complete	09/27/2016 12:00:00 AM	ADDRESS	34.14155	-118.37259	ti to an existing commercial building adding new lighitng new controls outdoors to existing panels.  plan check for energy only.  total square footage 1500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35183	19041-20001-36632	6330 N RANDI AVE	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18503	-118.61009	Expedite per applicant request Plan check for PV roof mounted system, System size: 30.015KW DC, 26.7KW AC with 69 PV Modules and 2 inverter(14.4KW )Applicant request: %%%%%%    Plan stay Van Nuys  %%%%%%%%Note: This is 12 buildings on 1 Plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35184	17041-20001-43820	17158 W KILLION ST	91316	5	174B133   718	2258002007	RE11-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.17076	-118.50761	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35185	15041-20000-03673	21021 W VENTURA BLVD 320	91367	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM			PC Approved	02/06/2015 12:00:00 AM	PIN	34.16705846	-118.59120236	PLANCHECK FOR T24 ENERGY. Office Tenant Improvement in Suite 320. 2477 SQFT, EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35186	12041-10000-13216	206 N LARCHMONT BLVD	90004	4	138B189   661	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.07488	-118.32343	Plan check for energy only.  1285sq ft WITH 16 SEATS (STARBUCK'S); occupancy load is less than 100.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35187	16041-10000-26578	19819 W VENTURA BLVD	91364	3	174B117   322	2164012018	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.17259	-118.56423	Plan check for T-24 only. Remove exterior HID fixtures and replace with new LED fixtures. Total affected area: 1,696 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35188	15041-10000-22000	616 S NORMANDIE AVE	90005	10	135B197  1114	5502031011	R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.06287	-118.30017	INSTALL NEW FIRE ALARM FOR 16 STOR BUILDING. WITH793 FA DEVICES AND 6 CONTROL PANELS AND ONE FA PANEL. PER APPLICANT FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35189	19041-10000-52669	12833 W VENTURA BLVD #101	91604	2	165B161   920	2375021022	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	05/10/2022 12:00:00 AM		Permit Finaled	08/29/2023 12:00:00 AM	ADDRESS	34.14508	-118.41248	FULL PLAN CHECK FOR A FIRST TIME TENANT - HEALTH CLUB (EQUINOX). INSTALLING NEW PANELS, CIRCUITS, LIGHTS,AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 28,821 SFT.BULDING PERMIT: 19016-10000-40615	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35190	12041-10000-01029	6320 N CANOGA AVE #700	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Approved	01/17/2012 12:00:00 AM	ADDRESS	34.18499	-118.59722	Ti in an existing office. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35191	11041-10000-02388	7801 S CENTRAL AVE	90001	9	099B209   251	6023029001	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	10/18/2011 12:00:00 AM	ADDRESS	33.96826	-118.25659	remodeling of laundromat	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35192	16041-10000-19757	6920-6930 N VAN NUYS BLVD	91405	6	183B149   499	2217009801	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Issued	03/22/2017 12:00:00 AM	ADDRESS	34.19604	-118.44846	PLAN CHECK FOR POWER ONLY.INSTALLATION OF FOUR NATURAL GAS FUEL CELLS RATED AT 480/277 V AND 250 KW EACH AT EXISTING AT&T DATA CENTER.  NEW STEP UP TRANSFORMER TO INTERCONNECT FUEL CELLS TO 4,160/2,400 V SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35193	16041-10000-38473	600 E MILDRED AVE	90291	11	106-5A147 105	4228004001	C1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			PC Approved	10/31/2016 12:00:00 AM	ADDRESS	33.98697	-118.46474	Plan check for Title 24 only in existing space T.I. Total area:	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35194	14041-20003-17303	5808 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	6/11/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 2 and Delta 3. Changes include downsizing the EM generator to 800 kW from 1000 kW, the EM distribution board has been separated to have sections, 10 new lighting control panels, the addition of 2 new civil sump pumps, addition of fire smoke damper circuits, relocation of additional circuits and upsizing of water heater circuit breakers. *****Previous Work Description*****A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35195	19041-10000-52213	2240 N BEACHWOOD DR	90068	4	151-5A189  50	5586010002	RD1.5-1XL	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Apartment			12/18/2019 12:00:00 AM			Permit Closed	01/11/2023 12:00:00 AM	ADDRESS	34.11129	-118.32128	FULL PC FOR A NEW APARTMENT, SCOPE OF WORK INCLUDES A NEW 600A SERVICE (120/240 3P,4W) THAT FEEDS A 600A  MAIN SERVICE SWITCHBOARD THAT SUBFEEDS A 225A HOUSE BOARD WITH AN ELEVATOR (20HP) AND 2 HOUSE PANELS. THE 600A SERVICE ALSO FEEDS 6 SUBPANELS (DWELLING UNITS). TOTAL AFFECTED AREA IS 12,554 SQFT. PER BUILDING ((3-STORY, 6 UNIT APARTMENT TYPE VA  WITH PARKING GARAGE AT 1ST FLOOR TYPE_. FIRE SPRINKLERS REQUIRED THROUGHOUT19010-20K-03482))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35196	16041-20000-38385	12700 W VENTURA BLVD Ste 300	91604	2	162B161    29	2384022049	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	Yes	1439.01	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.14449	-118.40998	TI to (E) commercial office suite on the 3rd floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35197	17041-20002-15066	2949 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.03799	-118.20329	8.10.2017 - Plan check for modifications to approved set. Equipment on AC side of system must be rated for 22kAIC. Breakers are series rated. SLD updated to show connection to MSP and AIC ratings.=====pv2install roof mounted pv system sized 1.7kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35198	11041-20000-17891	12541 W BEATRICE ST	90066	11	105B161   953	4211006026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	33.98116	-118.41478	PLAN CHECK T24 ENERGY/EMERGENCY FOR TENANT IMPROVEMENT ON 2ND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35199	19041-20000-45496	4024 N RADFORD AVE HR	91604	2	165B169   716	2368005011	[Q]M2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.14441	-118.39252	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS TITLE 24 PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35200	19041-20000-49783	11315 W VICTORIA AVE	90066	11	117B157   945	4234004021	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Issued	12/04/2019 12:00:00 AM	ADDRESS	34.0129	-118.42166	Plan check for PV roof mounted system, PV system size: 6.09KW DC, 7.6KW AC wtih 21 PV Modules and 1 inverter(7.6KW) and 1 LG Battery 9.8KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35201	16041-20004-04930	11511 W TENNESSEE AVE	90064	11	123B153   233	4260016005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.03484	-118.44331	08-03-16 Changes to an approved set of plan. Changes include replace different manufacturer of lighting fixtures  and add unit equipment for emergency lighting{{{{{{{{03/02/2016 Plan check for Title 24 only. Project site is an existing commercial building. Plan check scope is lighting work being done within a hazardous location. Total lighting area = 12,370 sq. ft.*****Previous Work Description*****PLANCHECK FOR POWER  FOR CAR SERVICE EQUIPMENT AND GARAGE. HAZARDOUS LOCATION.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35202	12041-10000-09943	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Public Safety Only			05/01/2012 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	NEW FIRE WARNING SYSTEM FOR COMMERCIAL BUILDINGS A & B	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35203	19041-20000-14366	11848 N JELLICO AVE	91344	12	216B129   380	2601042033	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.28477	-118.51719	Plan check for Battery back up system in to existing PV system, install 2 Power Wall 2.0(13.5KWh).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35204	15041-20000-29408	5656 N CRANER AVE	91601	2	174B173   678	2415006018	R2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.17378	-118.36907	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35205	15041-10000-14398	19550 W NORDHOFF ST	91324	12	195B117     9	2783028062	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.23529	-118.55947	NEW FIRE ALARM MONITORING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35206	17041-10000-30529	1318 N LYMAN PL	90027	13	147B197   960	5542012005	R4-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.09638	-118.28837	PC FOR A FIRE ALARM SYSTEM FOR A COMMERCIAL SPACE. SCOPE INCLUDES ADDING 91 FA DEVICES,  AND 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35207	14041-20002-16368	19331 W BUSINESS CENTER DR 102	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.23118	-118.55466	5/2/2017changes to an approved set of plans.  adding generator and associated em loads.  plan check for power and energy.  (((((Change of use from storage to vascular access medical clinic with critical care patient areas including lights, power and sub panels.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35208	10041-10001-10910	2666 W OLYMPIC BLVD	90006	1	129B197   273	5076009005	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM			PC Info Complete	08/25/2010 12:00:00 AM	ADDRESS	34.0522	-118.28994	Ti in an existing Skin Care Clinic. Plan check for T-24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35209	14041-10001-06144	5015 N BALBOA BLVD #101-#410	91316	5	171B133   627	2258016004	(T)(Q)R3-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.16219	-118.50134	04/05/16PC for power only. Changes to an approved set of plans. All changes are clouded under delta 2. Changes include adding three new 225A panels and 25 electric vehicle charge stations.((((New fully sprinkler 4-story, 42 unit apartment with two level basement garage.  New 2000A service.  Plan check for power and energy.Note: Due to pre-printed check, additional plan check fee is required for Title 24 for addition 54240 s.f.	Y	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35210	18041-10000-38059	4201 W WILSHIRE BLVD #220	90010	4	135B189   972	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.06189	-118.31911	PLAN CHECK FOR ENERGY ONLY FOR - TENANT IMPROVEMENT INCLUDING NON-BEARING WALL MODIFICATION, FINISHES, AND CEILING. - TOTAL AFFECTED AREA = 3665 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35211	18041-20002-09709	931 W OXFORD AVE	90292	11	105B149   457	4229002013	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	33.98604	-118.44881	Revision to approved set of plans.  Change of location of energy storage systems to garage interior.  Approval for delta-D revision only.  (((PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL (200A). PV IS EXISTING. TOTAL BATTERY SIZE INSTALLED : 10KWAC / 27KWH)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35212	15041-20000-08975	21926 W COSTANSO ST	91364	3	171B101   313	2169003042	C2-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.16743	-118.605	Plan check for Title 24 only based on 2008 energy code per Building Permit 14016-10000-12142. Project scope is a tenant improvement to an existing commercial space. Total lighting area = 1,093 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35213	12041-10000-04580	910 S WALL ST	90015	14	126A211   372	5145017034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Expired	02/02/2016 12:00:00 AM	ADDRESS	34.03829	-118.25211	Plan check for new 800A Delta system service for existing building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35214	18041-10000-15512	10880 W WILSHIRE BLVD #1020	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	34.05885	-118.44283	TENANT IMPROVMENT IN AN EXISTING OFFICE AREA ON THE 10TH FLOOR IN SUITE#1020.TITLE 24 - ENERGY ONLY.BULDING PERMIT # 18016-20000-11480	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35215	19041-10000-26376	22935 W VENTURA BLVD	91364	3	171B097   505	2042018020	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.16528	-118.62634	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35216	12041-20003-02012	5802 W WILLOUGHBY AVE	90038	13	144B189  1034	5534029003	[Q]C2-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.08696	-118.32253	"Modifications to previously approved set of plans.  New transformer to Elevator.  Plan check only for ""DELTA 3"" transormer changes.<<<<<  Warehouse and office building>>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35217	14041-20000-19954	18504 W CALLE VISTA CIR	91326	12	216B125   301	2872021036	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.285	-118.53471	PV1.  Install 5.4 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35218	17041-20001-44127	18741 W VENTURA BLVD	91356	3	174B121   517	2160002050	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.17139	-118.54204	Title 24 Part 6 plan review for lighting and controls per inspector correction notice.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35219	16041-20006-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	05/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 14. Changes have been made to indicated feeder sizes, lengths, and voltage drops.*****Previous Work Description*****SUPPLEMENTAL PLAN CHECK ONLYCHANGES TO AN APPROVED PLAN SET. CHANGES TO APARTMENT UNIT FEEDER SCHEDULE SIZES AND CALCS. CLOUDED DELTA 11 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35220	14041-10000-03541	1000 W ELYSIAN PARK AVE outdoor-pavilion	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	Plan check for power only in Dodger Stadium. the scope of work for this project is the removal of two (2) 500 kva substations, one each in the left and right field pavilion areas. the substation consist of 5kv load interrupter switch, transformer, and 208v switchboard. existing loads to remain in service are reconnected to existing substations.reference 13041-10000-33114 13041-10000-33117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35221	11041-10000-09982	754 S WALL ST	90014	14	126A211   123	5145005008	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.04061	-118.24966	REPLACING 600A SERVICE / SWBD WITH  A 800A SERVICE / SWBD ;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35222	18041-10000-14959	879 W 190TH ST #300	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	33.85951	-118.28963	PC FOR INTERIOR REMODEL OF EXISTING OFFICE SPACE IN A HIGH RISE BLDGFOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW CIRCUITS LIGHTS AND RECEPTACLES.  TOTAL AFFECTED AFREA  3204 SFB#17016-10000-14481	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35223	16041-10000-35581	1660 W 25TH ST	90732	15	009B193     3	7562017017	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	33.72387	-118.31415	T-24, PC FOR ENERGY ONLY. TI TO AN EXISING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 7000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35224	10041-10000-08893	2154 W SUNSET BLVD	90026	13	139-5A207 104	5402030016	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	12/28/2011 12:00:00 AM	ADDRESS	34.07735	-118.26555	Ti for two story existing building. EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35225	18041-20000-38859	156 W SLAUSON AVE unit 4	90003	9	108B201  1365	6005010027	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	33.98902	-118.27528	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35226	12041-10000-16262	6848 W SUNSET BLVD	90028	4	147B181   686	5548015003	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM			PC Info Complete	07/25/2012 12:00:00 AM	ADDRESS	34.0978	-118.34025	T.I. - Non-structural interior remodel to existing take-out restaurant (48'x22') including cabinet work and equipment installation.  No change of use. For electrical only title 24 . no H.R	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35227	18041-10000-17070	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM			PC Approved	07/09/2018 12:00:00 AM	ADDRESS	33.95466	-118.38556	"PLAN CHECK FOR TITLE 24 ONLY FOR - SIGNAGE FOR EXISTING HERTZ CAR RENTAL FACILITY 4 INFORMATION SIGNS (SIGN PMB) 2' 4"" X 2' 8""  MAX 6' 6"" HIGH."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35228	14041-10000-11152	777 S FIGUEROA ST 50thFloor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.04828	-118.26116	plan check for power and energy. 50th floor TI of hirise. Greater than 400A of connected load. BLDG#14016-10-06365: NON STRUCTURAL T.I. FOR OFFICE SPACE ON 50TH FLOOR :  NON-BEARING PARTITION WALLS , MILLWORK ; SUSPENDED CEILING PANELS . ( 14,714 sf. ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35229	19041-20001-38087	15301 W VENTURA BLVD Unit # P38-Unit #P39	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Issued	09/30/2019 12:00:00 AM	ADDRESS	34.15411	-118.46654	SUPPLEMENTAL PLAN CHECK FOR ADDITION OF OUTLETS TO SCOPE OF WORK. RELOCATING EXISTING OUTLETS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35230	16041-20000-33006	16530 W VENTURA BLVD	91436	5	168B137   374	2284005026	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	11/21/2017 12:00:00 AM		Issued	11/21/2017 12:00:00 AM	ADDRESS	34.15753	-118.49341	permit fee $0.00 by state senate bill no.1222PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:  75 KWDC  FEED IN TARRIF	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35231	17041-20001-08196	11258 W NEBRASKA AVE 1-5	90025	11	126B153   247	4261020004	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			03/14/2017 12:00:00 AM			PC Approved	03/29/2017 12:00:00 AM	ADDRESS	34.04413	-118.44561	EXPEDITE.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.25 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35232	19041-10000-03757	108 W 2ND ST 102-103	90012	14	130-5A213 201	5149006901	C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			PC Info Complete	01/31/2019 12:00:00 AM	ADDRESS	34.05097	-118.24511	PLAN CHECK FOR TITLE 24 ONLY FOR RESTAURANT. TOTAL EFFECTED AREA 2132 SQFT. BLD# 18016-10001-29868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35233	10041-10006-03624	6724 W HOLLYWOOD BLVD	90028	13	148-5A185 146	5547012018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.10139	-118.33715	Modifications to previously approved plnas for a T.I. for 8-story high rise building Church of Scientology.  Plan check for power and energy. New electrical system with 1600A service. Modification to seperate fire alarm system has been filed.(((((((((((((((((((((((((((   3-4-2014  change of fire pump from 150 to 250 kva.  everything to remain as it is  M.Zandi))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35234	15041-20000-26299	8751 N BRADLEY AVE	91352	6	195B173   469	2408023019	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.22856	-118.37494	Removing 2 existing services. Installing new 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35235	15041-20001-15525	8042 N RHODES AVE	91605	2	189B165   289	2309003018	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Expired	07/31/2017 12:00:00 AM	ADDRESS	34.2171	-118.40294	PC FOR DERATE THE MAIN BREAKER AND PERMIT FEE FOR MONITORING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35236	18041-10000-13769	15230 W PARTHENIA ST #1 -#41	91343	6	195B145   561	2654022017	(T)(Q)RAS4-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Apartment			04/16/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.22811	-118.46439	PC for power and energy for 41 unit 4 story apartment with subetarenean basement. Installing new 1200A 120/208V pullbox feeding 800A dwelling unit distribution board and 400A house distribution board. Total area indoor=36737sqft and outdoor=22085sqft. B# 17010-20000-03173. Fire Alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35237	14041-20001-12848	14333 W ADDISON ST 1-46	91423	4	171B153   727	2248008039	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			05/14/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.16135	-118.44556	((EXPEDITE FEES)))PV2 MULTIFAMILY DWELLING. USING COMBINATION OF MICROINVERTER AND 3 CENTRAL TRANSFORMERLESS INVERTERS. TOTAL SYSTEM RATING 16.7KW AC. USING TOTAL OF 70 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35238	14041-20001-05279	22210 W TIARA ST	91367	3	177B101   261	2146021003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.17795	-118.61061	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35239	12041-20000-08789	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Info Complete	04/17/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	High rise commercial. Plan check for energy only and emergency lighting. 590 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35240	16041-10000-17335	2939 W LEEWARD AVE 1-80	90005	1	132B197   276	5077016017	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.05886	-118.28782	METEANE MITIGATION & DETECTION SYSTEM WITH 30 FA DEVICES AND 10 CONTROLLERS FOR A NEW 80 UNITS APARTMENT BUILDING, 5 STORY HIGH (TYPE III-A) OVER 3 LEVELS OF UNDERGROUND PARKING GARAGE.B# 14010-10000-01634	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35241	19041-10000-31926	954 S CATALINA ST 1-19	90006	10	132B197  1160	5078007024	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Apartment			08/15/2019 12:00:00 AM			PC Info Complete	06/22/2021 12:00:00 AM	ADDRESS	34.05403	-118.29462	FULL PC FOR POWER AND ENERGY FOR A NEW APARTMENT, SCOPE OF WORK INCLUDES A NEW 1000A SERVICE (120/240 3P,4W) THAT FEEDS 400A HOUSE DISTRIBUTION BOARD THAT CONTAINS ALL ASSOCIATED HOUSE LOADS. THE SERVICE ALSO FEEDS A 800 MULTI-METERING SWITCHBOARD. TOTAL AFFECTED AREA IS 13,313 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35242	14041-20001-35568	13457 W MONTAGUE ST	91331	6	198B157   763	2625020018	RS-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.23692	-118.42618	Expedited per customer request.PV1. Install roof mounted PV system sized 10kW. Interconnected with main service pannel. (38) SW 250 modules(1) 10,000A inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35243	18041-10000-39171	3620 S VERMONT AVE	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.02213	-118.29133	PLANCHECK FOR T24 ENERGY. INTERIORT TEANAT IMPROVEMENT FOR OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35244	16041-10000-44401	7445 W SUNSET BLVD	90046	4	147B181   632	5550013015	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM			PC Info Complete	06/07/2017 12:00:00 AM	ADDRESS	34.09826	-118.35261	Plan check for power and energy, core and shell only.  2-story retail center (market-restaurant-shops).  2500MSA, total area indoor+outdoor 99,243 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35245	16041-10000-09096	900 W WILSHIRE BLVD 71st FLR	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT ON THE 71ST FLOOR OF A NEW  73 STORY, MIXED USED HIGH RISE BUILDING. SCOPE INCLUDES TWO NEW PANELS AND LIGHTING FOR A KITCHEN/DINING/RESTUARANT SPACE. TOTAL AFFECTED AREA IS 14,018 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35246	16041-10000-44008	12655 W SHERMAN WAY	91605	2	183B161    12	2324003046	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.20136	-118.40844	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 16115.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35247	19041-10000-48467	2500 S NAVY WAY	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	09/02/2020 12:00:00 AM		Issued	09/02/2020 12:00:00 AM	ADDRESS	33.73363	-118.2408	INSTALLING A NEW 277/4780, 3 PH, 475KVA WIRELESS INDUCTIVE CHARGER AT THE PORT OF LA. THE CHRGER SYSTEM ALSO INCLUDES A REMOTE POWER SUPPLY, POWER CABINET AND A CHILLER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35248	16041-10000-38237	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2623.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			Reviewed by Supervisor	11/23/2016 12:00:00 AM	ADDRESS	34.08469	-118.4849	Expired plan check. New plan check submitted under a different permit number 2019. Full Plan check for a new construction of a 2 story recreation center. Installing new service rated at 1000A 480/277V 3phase 4wire. New lighitng and power. Total sqft = 73217.PLAN CHECK 1 0F 2. PARKING STRUCTURE IS BEING SUBMITTED UNDER A SEPERATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35249	13041-10000-05917	2000 S AVENUE OF THE STARS 810N	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.05868	-118.41546	TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER ONLY.  PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ON A HIGH RISE OFFICE BUILDING TENANT IMPROVEMENT. SUITE 810N (NORTH)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35250	14041-20000-29412	16260 W VENTURA BLVD	91436	5	168B137   426	2284003033	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Issued	02/09/2015 12:00:00 AM	ADDRESS	34.15673	-118.48763	Plan check for power and energy. TI to existing outpatient health care facility.  Install new generator and new 225A distribution equipment (new panels, transformers, etc.). New lighting system. Rewiring some existing circuits. 4,180sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35251	18041-20001-45225	10506 W BLOOMFIELD ST	91602	4	165B177   496	2424012011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM			PC Approved	03/15/2019 12:00:00 AM	ADDRESS	34.1495	-118.35958	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, RELOCATION OF SERVICE PANELS AND CHANGES TO CONDUIT RUN, CLOUDED DELTA B CHANGES ONLY*ORIGINAL*Plan check for PV roof mounted system, system size: 10.08kW DC, 8.99 kW AC CEC with 28 AC Modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35252	16041-20003-44981	7183 WORLD WAY WEST	90045	11	090B157   100	4117032900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	33.94557	-118.41975	PLAN CHECH FOR DELTA #2 CHANGES ONLY - CHANGES INCLUDE ADDITION OF NEW DISTRIBUTION EQUIPMENT, NEW LOAD, AND RELOCATION OF EQUIPMENT ON PANELSchanges to an approved set of plans.  changes noted delta 1.  Portable crusher plant at LAX for temporary construction.  (1) power trailer, (1) 800amp mcc and (1) 600amp mcc.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35253	18041-20000-23175	10201 W PICO BLVD BLDG 5,6	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Approved	06/21/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	Plan check for Title 24 Engergy only  in existing two storied office building T.I. office Total area: 3161 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35254	18041-20000-21735	6174 N PETERSON AVE	91367	3	177B089   248	2033026021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.18319	-118.64601	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (19) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35255	18041-10000-25115	301 N WESTLAKE AVE	90026	13	136-5A205 403	5157025038	R4-1	Central	Westlake	Echo Park		2084.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.06887	-118.26727	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 470W CONSISTING OF 2 MODULES WITH MICROINVERTERS (IQPLUS-72-2-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35256	17041-20000-34905	644 N NORMANDIE AVE 1-12	90004	13	141B197   648	5520003037	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.08253	-118.30031	Plan check for power and energy. New 2-story, 12-unit apartment building over subterranean garage.800A 120/240V 3ph 4w service. 1 typical unit. T24 area - 8,438sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35257	17041-20000-32511	812 E 59TH ST	90001	9	105B205   153	6007005020	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	33.98709	-118.26081	Plan check for energy only. TI/Creating new offices within (E) factory. New lighting - 1,237sqft.COMPLY WITH DEPARTMENT ORDER effective date05/31/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35258	15041-10000-34390	312 S GRAND AVE	90731	15	018B197  1580	7451018002	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	33.74127	-118.28996	PV1, INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.CENTRAL STRING INVERTER.(7) kyocera #KU2656ZPA(1) ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35259	14041-20001-00680	3500 N MANDEVILLE CANYON ROAD	90049	11	153B133    66	4490021002	RE15-1-H	West Los Angeles			YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	34.11142	-118.49981	EXPEDITE FEES ONLY       <<<New 10.7kw Ground mounted PV system at a single family dwelling.  System is UNGROUNDED.  SERVICE PANEL SHALL BE ON A SEPARATE PERMIT.  Building Permit must be approved before electrical permit can be issued.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35260	13041-10000-24249	1118 S VALENCIA ST	90015	1	129A205   312	5137024213	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.04659	-118.27332	changes to approved set of plans 13041-10000-22617: shifted location of lobby, everything else the same. 1 story building.TI IN THE MAIN ENTRY LOBBY OF AN OFFICE BLDG. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35261	19041-10000-05332	19515 S VERMONT AVE	90502	15	057B197    23	7351034023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	33.85325	-118.29073	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35262	18041-20002-03184	5636 W BRIARCLIFF ROAD	90068	4	151-5A193 279	5587021013	RE11-1D	Central	Hollywood	Hollywood United	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.10883	-118.31319	04/13/2018 Changes to approved set of plans.  All changes clouded and marked delta-4. Relocation of utility meter and adding 200A main service disconnect.  *****Previous Work Description*****03/30/2018 Changes to an approved set of plans. All changes have been clouded. AC PV module count has been reduced to (24) modules and PV system interconnection has changed to reflect field conditions. Plan check for a PV1 roof-mounted PV system. System size is 9.3 kWac and consists of (29) AC PV modules and (1) load center. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35263	19041-10000-50694	548 N MUSKINGUM AVE	90272	11	126B121   190	4414004010	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	ADDRESS	34.04402	-118.53898	[EPLAN] NEW 1 ESS (TESLA POWERWALL), 1 200A SUBPANEL, WITH EXISTING MAIN SERVICE PANEL RATED FOR 225A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35264	16041-20002-40276	850 N MARIPOSA AVE	90029	13	141B197   109	5538006038	RD1.5-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Apartment			10/20/2017 12:00:00 AM			PC Approved	10/20/2017 12:00:00 AM	ADDRESS	34.08618	-118.29884	10.20.2017 - Plan check for changes to approved set. Update available fault current value at the house service panel based on LADWP commitment letter (21,000AIC) - recalculate available fault current at downstream equipment. Add new 400A subpanel. Show interconnection details for (E) panels. Changes clouded.======permit fee $0.00 by state senate bill no. 1222Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 37.7kW (6kW*5+7.7kW) ungrounded system. (136) 340W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35265	14041-20000-13012	19923 W LORNE ST	91306	3	189B113   175	2106026008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.21733	-118.56747	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.75KW INTERCONNECTED WITH MAIN PANEL.(1) TRANSFORMERLESS INVERTER SOLAREDGE SE5000-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35266	19041-10000-29344	227 N TIGERTAIL ROAD	90049	11	135B141   841	4403011026	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.06229	-118.47957	[E-Plan] PLAN CHECK FOR ROOF MOUNTED  3.68PV1 SYSTEM CONSISTING OF 16 MODULES(LG320N1K-A5) WITH 16 MICRO INVERTERS(IQ6-60-2-US) ON EXISTING 800A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35267	15041-10002-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM			PC Approved	03/24/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Change to an approved set by adding panels and circuits on the original plan. All changes under delta_13 only.permit fee is paid under application number 15041-10002-22097.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35268	18041-20000-33049	527 S WILTON PL	90020	4	135B189   738	5504019023	R3-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM	01/06/2020 12:00:00 AM		Permit Finaled	03/09/2021 12:00:00 AM	ADDRESS	34.06442	-118.31432	New 2-story 14-unit apartment building.  800A 240/120V 1ph-3w service.  COMPLY WITH DEPARTMENT ORDER effective date 08/01/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.Building permit filed under 16010-20000-01660.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35269	19041-10000-14060	220 S AVENUE 19	90031	1	138A221   247	5447024012	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.07153	-118.22075	PV1, ROOF MOUNTED SOLAR SYSTEM USING AC MODULES. (16) AC MODULES, (1) LOAD CENTER, (1) PV MONITORING EQUIPMPENT. TOTAL SYSTEM SIZE IS 5.76KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35270	14041-10000-25423	1406 W MANCHESTER AVE	90047	8	097-5A195 289	6037015028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	33.95984	-118.30079	Hazardous location for new installation of soil vapor, ground pump and  treatment system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35271	15041-20000-11667	600 WORLD WAY Space 621	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	Plan check for Title 24 only. Project scope is the installation of (2) illuminated signs within Terminal 6 of LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35272	16041-20001-11659	20513 W QUEDO DR	91364	3	169-5A111  64	2166023008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	34.15891	-118.5797	Expedited per applicant request.Plan check for the addition of a 3 kWac PV1 PV system onto an existing PV system PV addition consists of (1) inverter, (17) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35273	14041-10000-35463	15400 W SHERMAN WAY	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	34.20099	-118.46839	Energy plan check for an office T.I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35274	14041-20000-19665	7751 W BEVERLY BLVD	90036	5	138B177   431	5527039001	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.07628	-118.3586	New electrical equipment for an existing gas station for the addition of a hydrogen fuel dispenser.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35275	19041-10000-38424	825 S HILL ST	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM			PC Info Complete	02/11/2020 12:00:00 AM	ADDRESS	34.04392	-118.25657	ENERGY PLAN CHECK FOR A CHANGE OF USE TO A (N) RESTAURANT. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 1,694-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35276	16041-10000-38803	6904 S LA TIJERA BLVD	90045	11	102B173   175	4103010002	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	33.97579	-118.37323	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALD'S RESTUARANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS SQ. FT.B#16014-10000-05197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35277	18041-20000-32580	11826 W SAN VICENTE BLVD	90049	11	129B145   122	4265018009	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	34.05276	-118.46886	Power/lighting for retail shell space.  Total area: 3308  sq ft. B#18016-10000-16837	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35278	19041-10000-03392	4377 N VINELAND AVE	91602	4	165B173   381	2423013022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	12/04/2020 12:00:00 AM		Permit Finaled	07/08/2022 12:00:00 AM	ADDRESS	34.15002	-118.3706	FULL PLAN CHECK FOR PROPOSED RETAIL STORE / MARKET ; OTHER STRUCTURES AND BUILDING ARE NOT INCLUDE IN THIS PLAN REVIEW.B# 18010-10000-05488 FOR CANOPY       18010-10000-05489 FOR STORE      18010-10000-05490 FOR CAR WASH      18010-10000-05491   FOR TRASH ENCLOSURE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35279	16041-10000-27704	1249 W 58TH ST	90037	9	108B197  1276	5002014016	RD1.5-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Refund in Progress	11/10/2016 12:00:00 AM	ADDRESS	33.98998	-118.29762	PV1 NEW 5.07 KW DC ROOF-MOUNTEFD SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16)MODULES:SUN POWER SPR-E20-327(2 ) INVERTER: SMA SB-30000US-22*2 STRUCTURES UNDER THE SAME ADDRESS PER B.O.E.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35280	19041-20000-52306	1709 W 6TH ST	90017	1	132A205    26	5153004024	C2-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			Reviewed by Supervisor	02/06/2020 12:00:00 AM	ADDRESS	34.0576	-118.2701	FULL PLAN CHECK, NEW 2000A AND 4000A SERVICE, (124) PANELS, (3) EQUIPMENTS, A GENERATOR, AND T24. TOTAL SQUARE FOOTAGE = 109,990 SFB#19010-10000-05743	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35281	16041-20000-21945	7937 N KEER DR	91335	12	189B125  1020	2102015093	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.21504	-118.53492	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35282	14041-10000-15982	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM			Verifications in Progress	09/17/2014 12:00:00 AM	ADDRESS	33.78054	-118.23195	PLANCHECK FOR POWER. INSTALLATION OF A 2000KVA TRANSFORMER AT SUBSTATION 2  IN VALERO WILMINGTON REFINERY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35283	17041-10000-33261	8758-8762 W PICO BLVD	90035	5	132B169  1007	4303001002	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.05445	-118.38292	PC FOR fire damage repair FOR TITLE 24 ENERGY ONLY TOTAL AFFECTED AREA 8930 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.Plan Check is done on supplemental 17041-10001-33261	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35284	16041-10000-41222	9028 N LANGDON AVE	91343	7	195B145     6	2654003045	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.05	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.23456	-118.46965	PC for title 24, outdoor lighting. Remove HID fixtures and replace with new LED fixutures. Totalsqft = 132,050.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35285	10041-20000-02853	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL, [Q]R3-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00, 1204.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	03/17/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.2215	-118.42999	T.I work in existin medical office of Kaiser Permanente in NORTH III MOB. This plan check is for power and energy. Not plan-reviewed for OSHPD III	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35286	14041-10001-14926	5324 S 9TH AVE	90043	8	108B185   216	5006018020	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	33.99417	-118.32677	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.315 KW DC ROOF-MOUNTED SOLAR ARRAY ON ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35287	11041-10000-26802	6430 W HOLLYWOOD BLVD	90028	13	148-5A187 177	5546007002	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.10143	-118.33063	Title 24 Energy and emergency lighting. Hookah lounge.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35288	11041-20000-20241	904 N VINE ST	90038	13	144B189  1006	5534028030	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.0873	-118.32642	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35289	16041-10000-42334	18756 W SHERMAN WAY	91335	3	183B121   144	2126003024	[Q]C2-1VL-CDO-RIO, [Q]P-1VL-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.20094	-118.54227	PC FOR ENERGY. REPLACE OUTDOOR   FIXTURES WITH NEW LED FIXTURES  TOTAL AREA 17100 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35290	19041-10000-15367	725 S FIGUEROA ST 21st floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	pc for energy only. TI (restroom and lobby) in highrise building. scope area 512SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35291	10041-20000-11514	5802 W WILLOUGHBY AVE	90038	13	144B189  1034	5534029003	[Q]C2-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM			PC Info Complete	11/07/2011 12:00:00 AM	ADDRESS	34.08696	-118.32253	plans expired resubmit same plans original missing	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35292	18041-10000-27374	2410 N HYPERION AVE	90027	4	148-5A205  62	5432003025	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM			PC Approved	07/23/2018 12:00:00 AM	ADDRESS	34.10298	-118.27293	PC FOR ENERGY TO AN OFFICE TI. SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS, NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 6697Plan is resubmitted under application number : 18041-10000-38196	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35293	15041-10000-06128	505 N FIGUEROA ST 1-296	90012	1	135A213   358	5407002023	C2-2D	Central	Central City	Historic Cultural		2071.01	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.06228	-118.2469	$0 submittal fee is due to State Senate Bill SB-1222. PV2 325KW roof-mounted system including (1) Solectria SGI 225PE and (1)Soelectria PVI 100KW inverter, (18) combiner box,  and (1932) Innotech Solar 260W modules interconncting to the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35294	19041-20000-15611	3032 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	06/15/2021 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35295	14041-10000-03885	7565 W SHORE CLIFF DR	90045	11	099B157   570	4114004048	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	12/09/2022 12:00:00 AM	ADDRESS	33.96509	-118.4304	PV1, Install 4 kW DC roof-mounted solar array on a two-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) Modules: CANADIAN SOLAR CS6P-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35296	19041-20001-36681	22101 W ERWIN ST	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.183	-118.60884	Expedite per applicant request Plan check for Pv roof mounted system, PV system size: 24.7KW DC, 21.36KW AC CEC with 56 PV Modules and 2 inverters(14.4KW and 9.0KW)Applicant reques: %%%%%%%%%%      Plan stay Van Nuys    %%%%%%%Note: This is 12 Buildings on 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35297	15041-20001-11167	8551 W WONDERLAND AVE	90046	4	153B169   549	5564005003	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM			PC Approved	05/05/2015 12:00:00 AM	ADDRESS	34.11417	-118.38082	Change to approve set of plan. {{{{{Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35298	16041-10000-13219	633 W 5TH ST LEVEL 1	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Expired	06/07/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW OUTDOOR LIGHTING AND PROVISIONS FOR RECEPTACLE LIGHTING. TOTAL SQ. FT. 1400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35299	17041-20000-16541	20801 W VENTURA BLVD	91364	3	171B109    62	2166033052	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Issued	07/18/2017 12:00:00 AM	ADDRESS	34.16663	-118.58589	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 98,019 sq. ft.Note: Building application has been generated under 17016-20000-12917	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35300	17041-20000-32649	4921 N MEDINA DR	91364	3	168B105   450	2171013050	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.15764	-118.60134	Plan check for solar pv system, roof-mounted on SFD.6.67kW ungrounded system.(29) EnPhase IQ6 microinverters.(29) 295W pv modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35301	11041-10000-27251	11755 W WILSHIRE BLVD 22nd Fl	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM			PC Approved	12/22/2011 12:00:00 AM	PIN	34.04869377	-118.46238681	T.I. REMODEL, Plan check for T-24 lighting compliance and emergency egress ltg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35302	15041-10000-34618	700 E SLAUSON AVE	90001	9	108B205  1503	6007001009	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	PIN	33.98868086	-118.26338603	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35303	19041-20000-18301	2826 S GRAND AVE	90007	9	120A205   103	5122011015	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	02/10/2022 12:00:00 AM	ADDRESS	34.02398	-118.27367	Change of use from manufacturing to adult art academy.  New 600A 240/120V 3ph-4w delta service, lighting, and power.  Building permit under 19016-10000-08790.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35304	15041-10001-29935	10944 W VENTURA BLVD	91604	2	162B173   609	2378007006	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1438.00	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM			PC Approved	05/31/2016 12:00:00 AM	ADDRESS	34.13979	-118.36893	Revision to approved set per field installation under Delta-1. Revised qty. of the light fixtures. This is PC only, permit under master E# 15041-10000-29935<<ALTERATIONS IN EXISTING COMMERCIAL BUILDINGNEW LIGHTING, CIRCUITS AND RECEPTACLESPLAN CHK IS FOR TITLE 24>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35305	11041-20000-23895	1115 S BOYLE AVE #201	90023	14	123A221   272	5170008029	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			11/08/2011 12:00:00 AM			PC Approved	11/08/2011 12:00:00 AM	ADDRESS	34.0308	-118.22044	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE TI #201. EXISTING PERMIT UNDER #11041-90000-23140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35306	10041-10000-25131	8500 W BEVERLY BLVD # 774	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	05/26/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	REMODELING AND INCREASING THE SIZE OF RETAIL STORE LOUIS VUITTON	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35307	18041-20000-18375	8219 N QUIET HILLS CT	91304	12	192B089    92	2020032027	RE40-1-H-K	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.21851	-118.64834	Plan check for the addition of a battery storage system onto an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35308	15041-10000-34824	11103 W TUXFORD ST	91352	6	195B173    98	2408033004	M3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.23336	-118.3733	T-24, TO AN (E) INDUSTRIAL BUILDING. SCOPE INCLUDES REPLACING OLD LIGHTS WITH NEW LED LIGHTS. TOTAL SQ. FT. 6092	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35309	15041-20000-23074	7144 W HILLROSE ST	91042	7	207B197   897	2566005001	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.26272	-118.28724	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.2 KW. STANDARD CENTRAL INVERTER PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35310	17041-10000-30267	1243 N HIGHLAND AVE	90038	4	144B185   215	5532006024	C2-1D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.09377	-118.33883	Energy plan check for removing HID fixtures and replacing with new LED fixture. Total area is 7425 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35311	19041-20000-31153	3626 W MONON ST	90027	4	151-5A205 193	5433026024	RD1.5-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Apartment			08/09/2019 12:00:00 AM			Reviewed by Supervisor	08/30/2019 12:00:00 AM	ADDRESS	34.10841	-118.27262	Plan check for power only 600A Service upgrade to multi-family building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35312	11041-20000-04258	10800 W PICO BLVD #369	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM			PC Info Complete	03/17/2011 12:00:00 AM	ADDRESS	34.04054	-118.4272	T.I. to a retail space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35313	17041-10001-01665	10645 N HILLROSE CIR	91040	7	207B189   778	2547010043	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	03/31/2017 12:00:00 AM	ADDRESS	34.2627	-118.3253	EXPEDITE FEESPC FOR PV SYSTEM USING 11.4KW AC INVERTER AND TOTAL OF 40 MODULES. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35314	18041-10000-01587	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	FULL PC FOR POWER AND ENERGY ONLY. SCOPE INCLUDES NEW 400A 3PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 30863 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35315	16041-20000-33395	2159 E BAY ST	90021	14	123A217   424	5166001002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.03156	-118.22794	Plan check for power only. Replacing 1200A service equipment. New 1200A service panel. New distribution is included under application #16041-20000-33390.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35316	15041-20002-20622	19566 W VENTURA BLVD	91356	3	174B117   324	2164016027	C2-1VLD, P-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Issued	08/20/2015 12:00:00 AM	PIN	34.17217845	-118.55930747	"Changes to approved set.  Addition of 10 new branch circuits.  Changes to lighting layout.  Changing switch type from ""Wattstopper"" to ""Lutron""*****Previous Work Description*****   07/27/2015 Changes to an approved set of plans. Changes have been made to the lighting floor plan to reflect field changes. Changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check Title 24 only for Beauty Salon. Existing branch circuits. Total indoor lighting area: 1,066 SF"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35317	10041-10000-10517	700 W WORLD WAY Terminal 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	PIN	33.94153561	-118.3984113	PLAN CHECK TO INSTALL NEW VEHICLE BATTERY CHARGING STATIONS FOR UNITED AIRLINES TERMINAL 7& 8, HANGAR 1, HANGAR 2, AND CARGO BLDG AT LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35318	16041-30000-11840	18555 W VENTURA BLVD A	91356	3	174B125   543	2160007037	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.1697	-118.53779	Plan check for power and Title-24.  Total area = 1,930 sq. ft.     T.I. to commercial first time tenant.  Pharmacy space with retail section and office section.  One new subpanel and lighting + receptacle loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35319	10041-20000-23125	800 N ALAMEDA ST K2	90012	14	132A215    65	5409023054	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.05494	-118.23752	Plan check T24 energy for Subway kisok (K2) in Union Station.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35320	16041-20001-37052	7500 N DE SOTO AVE	91303	3	186B109   380	2113012006	RA-1, RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.20666	-118.58826	11/17/2016 Plan check for Title 24 only. Project site is an existing chruch. Project scope is a tenant improvement. Total lighting area = 4,370 sq. ft.*****Previous Work Description*****CHANGE OUT LIGHTS, EXIT LIGHTS AND BUG EYES.  PROJECT IS CONSIDERED A MODIFICATION IN PLACE AND DOES NOT REQUIRE TITLE 24 PLAN CHECK PER 141.0(b)(I)(iii)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35321	19041-20000-19788	9131 N DARBY AVE 1-146	91325	12	198B125   257	2764013012	(T)(Q)R3-1	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Closed	01/11/2021 12:00:00 AM	PIN	34.2360127	-118.53407302	FIRE ALARM PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN NEW 5-STORY 146 UNIT MIXED USE APARTMENT RETAIL BUILDING. 1 FACP AND 445 FA DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35322	19041-20000-11280	20909 W GERMAIN ST	91311	12	207B109   418	2706017029	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.26326	-118.58923	PV1.  Install 6 kW DC / 5.376 kW AC roof mounted grid tied PV system with (E) 4 kW PV system on site.  (20) modules with 7.6 kW rated EV charging inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35323	17041-10000-27795	2600 W WILSHIRE BLVD	90057	1	133-5A201 122	5141008900	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.06041	-118.28167	REMOVE HID FIXTURES AND REPLACE WITH NEW LID FIXTURES - T/24 ONLY. TOTAL SQUARE FT 9350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35324	11041-10000-11189	13535 W VENTURA BLVD	91423	4	165B157   672	2360007038	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	06/01/2011 12:00:00 AM	ADDRESS	34.14768	-118.42818	TENANT IMPROVEMENTS TO EXISTING STARBUCKS COFFEE. Title 24 energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35325	17041-10000-23667	1814 W SUNSET BLVD	90026	13	139-5A209 101	5404016007	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.07764	-118.25988	PC FOR T.I. TO A RESTAURANT FOR TITLE -24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 729 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35326	17041-10000-06587	564 W 2ND ST	90731	15	018B197  1304	7451008019	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Expired	10/15/2018 12:00:00 AM	ADDRESS	33.7425	-118.28921	PC FOR SOLAR SYSTEM ON SFD. ROOF TOP INSTALLATION. TOTAL SYSTEM SIZE 6.8KW AC. SYSTEM USES AC MODULES. 21 IN TOTAL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35327	16041-10000-03575	5939 N TOPEKA DR	91356	3	177B121   726	2156014007	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.17832	-118.54628	PV1. INSTALL 14.72 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(45) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTERS: SMA SB7700TL & SB5000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35328	11041-20000-11680	8810 N TAMPA AVE	91324	12	195B121   511	2784003069	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM			PC Approved	06/07/2011 12:00:00 AM	ADDRESS	34.23097	-118.55317	T.I. to existing building.  Install general lighting in Optical Kiosk area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35329	11041-10001-22369	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.05436	-118.25543	ADDING FA DEVICES TO NEW FA SYSTEMNew and replacement fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35330	15041-10000-17191	200 WORLD WAY TER-2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	FIRST TIME TENANT, RESTAURANT IN LAX. PC FOR POWER AND ENERGY. TOTAL SQ FT. 3756	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35331	13041-10000-25757	12121 W WILSHIRE BLVD #1240	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	PIN	34.04391963	-118.46825257	PC FOR ENERGY ONLY. TI TO (E) OFFICE.  HIRISE. HAS GEN.# 1240 (defense tax group - wilshire bundy plaza)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35332	12041-10000-08023	8500 S OSAGE AVE	90045	11	096B173    80	4127024018	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM	04/09/2012 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	ADDRESS	33.96139	-118.37862	using part of a warehouse area to create offices and a storage area with chain-link gate within the warehouse areaplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35333	14041-10001-28438	633 W 5TH ST Level 2	90071	14	130-5A209 144	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	Change to approved set by adding a new 400-Amp distribution board on the plan. existing distribution board ,TMSA,  also being updated . All change are under delta-11 only.PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR US BANK BUILDING. LEVEL 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35334	17041-10000-06248	25835 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	33.78945	-118.29472	PC FOR FUEL CELL SYSTEM. INTERCONNECTING TO 2 DIFFERENT SERVICE MEETERS. THIS IS PROJECT 1/2. SPECIFIC FOR ADDRESS 25835 VERMONT. CONTROL SYSTEM AND LOCATION IS SHARED WITH OTHER PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35335	15041-10000-26730	11111 W SANTA MONICA BLVD STE 1440	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC FOR ENERGY ONLY, T-24 TO AN (E) HIGH RISE BUILDING. EXTENDED OFFICE SPACE.  TOTAL SQ. FT. 1496	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35336	19041-10000-44800	5425 N ALDEA AVE	91316	5	174B133   788	2258001023	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.16985	-118.50821	$0 FEE DUE TO AB1414[EPLAN] PLAN CHECK FOR ROOF MOUNTED 13KWDC/12.6KWAC PV1 SYSTEM CONSISTING OF 40 MODULES(PANASONIC 325) WITH 40 MICROINVERTERS (EMPHASE IQ7X-96 315) WITH 3 ESS(TESLA POWERWALL) CONNECTED TO EXISTING 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35337	19041-20000-29155	20900 W VENTURA BLVD	91364	3	171B109    98	2167024047	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.1662	-118.58863	Renovation of (E) commercial space to repair/replace damaged electrical equipment.  Like-for-like replacement.COMPLY WITH DEPARTMENT ORDER effective date07/22/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35338	15041-10000-25952	2002 W SLAUSON AVE	90047	8	105B189    20	6001001900	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	33.98891	-118.31398	NEW F A SYSTEM. (50) FA DEVICES. REFERENCE APP# 15041-10000-25943 (((PC FOR POWER AND  ENERGY TO A NEW (2) STORY COMMERCIAL BLDG. 600 AMP SERVICE, SET OF PLANS INCLUDE FIRE, AND PV SYSTEM. FIRE AND PV SYSTEM TO BE DEFERRED  BY APPLICANT  BEFORE ISSUING PERMIT OF PLANS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35339	17041-10001-30232	927 N ORANGE DR	90038	4	144B181   716	5532010051	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.08796	-118.34173	REVISED PLANS TO SHOW CHANGES TO THYE LIGHTING SYSTEM AND THE ADDITION OF 2 EA INVERTERS FOR EM LIGHTING.ALL CHANGES ARE CLOUDED ON THE PLANS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35340	16041-10000-15036	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Info Complete	04/28/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	TITLE 24 FOR CAS OFFICE RENOVATION. EXISTING BRANCH CIRCUITS WITH TOTAL AREA OF 757 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35341	10041-20000-07982	2457 N HYPERION AVE	90027	4	150A205   348	5433018026	C1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.10404	-118.27356	Plan check T-24 Energy (general/emergency) lighting for TI of existing take-out restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35342	17041-20000-41376	849-857 N BUNKER HILL AVE	90012	1	135A213   128	5407007007	R4-1	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Apartment			11/15/2017 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	09/14/2022 12:00:00 AM	ADDRESS	34.0644	-118.24259	New 6-story 37-unit apartment building.  1600A 240/120V 3ph-4w service.   BUILDING PERMIT: 16010-10000-03531	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35343	14041-20001-21491	18321 W VENTURA BLVD SUITE #100	91356	3	171B125    82	2160009005	C2-1L, PB-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.16715	-118.5315	11/18/2014 - Modification to approved set. Plan check for changes - add photocells in daylit zones, update all controls to a Watt Stopper control system (including dimmers, occupancy sensors, and relays).[CHG OF USE TO BANK FROM OFFICE & TI. pc for t24 energy only. new lighting.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35344	14041-10000-04149	13180 W TONOPAH ST	91331	6	192B157    34	2627020005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.22685	-118.41971	PV1, Install 4.5 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 5000A-US-ZB-U. (18) Modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35345	15041-20000-07309	23254 W FRIAR ST	91367	3	177B093    44	2035020041	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.18529	-118.63355	Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  40 modules (6 strings) connected to 2 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35346	17041-20001-38052	660 S VETERAN AVE	90024	5	135B149   467	4363013038	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			10/23/2017 12:00:00 AM			PC Approved	11/08/2017 12:00:00 AM	ADDRESS	34.06501	-118.45379	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on apartment building.Total system size: 32.4kW ungrounded.(2) 9kW SolarEdge inverters.(1) 14.4kW SolarEdge inverter.(125) 275W pv modules.(125) 300W power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35347	17041-10001-30693	1677 N AMALFI DR	90272	11	132B133    27	4425022027	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM			PC Approved	10/16/2018 12:00:00 AM	ADDRESS	34.06143	-118.50025	DELTA 1 CHANGES TO APPROVED PLANS.Install (2) new AC powerwall system at 5.8 KVA each	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35348	15041-10004-13990	6121 W SUNSET BLVD	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	3/29/2016REVISION TO AN APPROVED SET OF PLANS. CHANGES WERE MADE TO THE LIGHTING FLOOR PLAN AND T24 PAGES WITH ADDITONAL  LOADS. NOTE CHANGES ON DELTA 3 AND 4.  {{{FULL TI TO ALL 6 FLOORS. CORE AND SHELL UNDER SEPARATE PERMIT. THIS TI IS FOR THE NEUEHOUSE.THIS IS A NEW SUBMITTAL WITH NEW PERMIT. ALL PREVIOUS APPLICATIONS VOID. THIS PLAN CHECK AND PERMIT TO COMPLY WITH 2008 VERSION OF THE CALIFORNIA ENERGY CODE.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35349	13041-10000-07225	2106 N ECHO PARK AVE	90026	13	144A211   143	5420035030	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			PC Approved	03/22/2013 12:00:00 AM	ADDRESS	34.08966	-118.2498	"2 STORY 16'-6"" x 26'-0"" ADDITION AND 559 SQUARE FEET COVERED OUTDOOR DINNING AREA ADDITION TO EXISTING ONE STORY COFFEE SHOP. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35350	13041-10000-16405	750 S LAMAR ST RD CREW-CHANGE	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (5.)  ROAD CREW CHANGE BUILDING. 7 PANELS, THREE TRANSFORMER AND OTHER LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35351	19041-10000-27685	353 S BROADWAY 400	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	34.04991	-118.24934	T-24 PLAN CHECK FOR A TI TO AN OFFICE SPACE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA 3,738 SQ.FTB# 17016-10000-33290	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35352	19041-20000-41057	11881 W TERRA VISTA WAY #111	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/12/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35353	15041-20000-42882	12954 W MAGNOLIA BLVD	91423	4	171B161   579	2358031016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.16472	-118.41547	PV1.  Install 20.8 kW DC roof-mounted utility-interactive PV system.  (64) SunEdison SE-F325BzC-4y modules w/ (2) SolarEdge SE7600A-US and (1) SolarEdge SE3800A-USNote: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35354	12041-20000-11822	3107 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.02997	-118.37367	Service upgrade to 600A.  New switchboard, subpanels, and branch circuits.  Plan check for energy and power.Note: Verified with Inspector Armond Gregoryona to issue electrical permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35355	16041-20001-28722	5716 N WILBUR AVE	91356	3	174B121   201	2156022003	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	ADDRESS	34.17509	-118.54441	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35356	18041-20000-24553	4141 W SANTA MONICA BLVD	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	Plan check for a fire alarm system for a 3-story hotel. Fire alarm consists of (1) FACP and (172) devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35357	10041-20000-16083	18401 W SHERMAN WAY	91335	3	183B125   149	2119022015	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	03/17/2011 12:00:00 AM	ADDRESS	34.20129	-118.53385	"CHANGE OF USE FROM (E) 21'8"" X 128'4""GYMNASIUM TO RESTAURANT. Lighting are existing to remain exept for Changing room and storage. EPC is for power and energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35358	16041-20001-29027	18825 W SATICOY ST	91335	3	186B121    91	2103016040	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.20853	-118.54321	5/15/17changes to an approved set of plans.  changes include recalculation of energy compliance indoor/outdoors.  this is plan check only.(((((Plan check for power and energy. ADDITION OF [BANQUET HALL WITH KITCHEN SCHOOL  CLASSROOMS AND  WITH ROOF TOP PLAY AREA FOR THE SCHOOL] TO THE EXISTING CHURCH BUILDING. New 800A distribution fed off existing 1600A service. 10,097sqft indoors. 4,061sqft outdoors.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35359	18041-10001-22315	6855 S LA CIENEGA BLVD	90045	11	102B173   135	4103001009	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	02/03/2020 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	33.97564	-118.37051	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDITION OF LOADS, RELOCATION OF EXISTING LOADS, REDO-LOAD CALCULATION, LIGHTING AND PHOTOMETRICS. ALL CHANGES HAVE BEEN CLOUDED UINDER DELTA #2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35360	18041-10000-46065	11625 W PICO BLVD	90064	11	123B153   598	4260027041	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Issued	12/04/2018 12:00:00 AM	ADDRESS	34.03235	-118.44458	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL WITH 84 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35361	18041-20000-20553	919 S HARVARD BLVD	90006	10	132B193   961	5093016024	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2125.01	Electrical	Electrical	Apartment			06/04/2018 12:00:00 AM	07/29/2020 12:00:00 AM		Permit Finaled	03/10/2022 12:00:00 AM	ADDRESS	34.05521	-118.30434	Plan check for power and energy. Project site is a new 5-story, 24-unit apartment building. Work includes a 1,000-amp service and a total lighting area of 12,420 sq. ft.Note: Building application has been generated under 17010-10000-04601	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35362	18041-20002-42525	644 S RAPALLO AVE	90732	7	015B189   207	7559031008	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	33.73717	-118.31692	Revisions to approved set.  Change of string conductor size.  (((Plan check for PV roof mounted system, system size: 9.9kW DC, 8.415kW AC with 33 PV Modules and 1 inverter(10.0KW))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35363	18041-20000-41017	500 S WESTMORELAND AVE	90020	13	135B197   803	5077004015	R4P-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			10/25/2018 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.06494	-118.28826	service upgrade 600 amps to an existing apartment building.  reconnecting to existing loads.   plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35364	16041-10001-20127	9301 N TAMPA AVE #17	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/20/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Changes to approved set noted under Delta-1: Changes on qty of light fixtures due to Architectural design change (add toilet room)<<PC for T-24 only, TI on (E) commercial build., combine 3 spaces into 1. New connected load < 400. Total area: 4,360 sq. ft.  B# 16016-10000-13245>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35365	15041-10000-26193	1355-1357 S ABBOT KINNEY BLVD	90291	11	108B145  1290	4239027014	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	33.99081	-118.46608	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 1612.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35366	14041-20000-19894	18231 W HERBOLD ST	91325	12	201B125   352	2764017057	RE9-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.24523	-118.53057	Standard plan: 7.1KW PV1 roof-mounted system with a 125Amp load center, (33) Hyundai 255w module and Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35367	11041-10001-18460	8500 W BURTON WAY 1-88	90048	5	138B173  1128	4334016087	(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			10/11/2011 12:00:00 AM			PC Approved	10/14/2011 12:00:00 AM	ADDRESS	34.07095	-118.37677	Modification to previously approved set of plans.  Switch board changed from 1000A to 800A <<<<TEMPORARY POWER FOR THE CONSTRUCTION SITE OF A NEW 88-UNIT APARTMENT BUILDING.  PLAN CHECK IS FOR POWER.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35368	15041-20000-01764	6220 N TOPANGA CANYON BLVD SUITE 1480	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	Plan check for power and energy. First time tenant, new restaurant  Luicilles BBQ suite 1480. Total Sqft. 9,970.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35369	19041-10000-50687	6467 N BERTRAND AVE	91335	3	180B129   705	2123012001	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.18861	-118.52447	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 6.83KWdc (6KWac & 6.29KWcec) USING 21 VBHN325KA03 MODULES, 21 SE P400 POWER OTIMIZERS & 1 SE-6000H-US CENTRAL INVERTER. CONNECTED TO A 100 AMP EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35370	18041-20000-22586	19634 W VENTURA BLVD Suite 110	91356	3	174B117   342	2164014020	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.17247	-118.56127	Plan check for power and energy change of use from office to Medical office new lighting and power. Total area: 1972 sq ft. B# 17016-20000-22904	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35371	19041-10000-20047	1173 W 19TH ST	90731	15	012B193   937	7460027004	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2972.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	33.7269	-118.30287	PV1 - PC FOR PV SYSTEM. SYSTEM SIZE IS 3.420 KW. SYSTEM CONSISTS OF (12) HANWHA Q-CELL MODULES W/(12) P320 OPTIMIZERS, (1) SE3800 SOLAREDGE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35372	19041-10000-14085	6521 N RESEDA BLVD	91335	3	180B125   488	2127011028	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.18907	-118.53628	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35373	17041-20000-00386	1880 S CENTURY PARK EAST 6th Floor	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only. Project site is the common restrooms on the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 460 sq. ft.Note: Building application has been generated under 16016-10000-25291	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35374	19041-30000-22602	12820 W PANAMA ST	90066	11	105B157   395	4223008012	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	33.98477	-118.42659	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 12,300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35375	17041-20000-37886	18237 W LOS ALIMOS ST	91326	12	207B125   200	2715010021	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			Reviewed by Supervisor	11/01/2017 12:00:00 AM	ADDRESS	34.26557	-118.53125	addition of (2) tesla power walls.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35376	13041-20000-06821	1520 N SAN PABLO ST	90033	14	135A225    64	5202004041	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.0627	-118.20276	Plan check for power and energy. Addition of an CT machine to a medical office. Not licensed by the State of California. USC HCT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35377	19041-20000-48987	15828 W SUTTON ST	91436	5	165B141   132	2283014018	RE15-1-H	South Valley	Encino - Tarzana	Encino		1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.1514	-118.47854	PV1. INSTALL 11.16 KW DC PV SYSTEM WITH (36) MODULES AND SUNNY BOY (3.8-US) RAPID SHUTDOWN SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35378	15041-10000-06516	6220 N TOPANGA CANYON BLVD BLDG E	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.1841	-118.60553	NEW FIRE ALARM SYSTEM IN BUILDING E AS MAIN FIRE ALARM SYSTEM FOR BUILDINGS A,B,C,D ON WESTFIELD PLAZA. 127 DEVICES AND ONE FA PANEL.B# 13010-10000-02908.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35379	11041-10000-10706	15821 W VENTURA BLVD # 370	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM			PC Approved	05/25/2011 12:00:00 AM	ADDRESS	34.15584	-118.47812	REMODELING OF OFFICE SPACES-ENCLOSING AREAS TO FORM OFFICES AND LUNCH ROOMS PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35380	12041-20001-22598	3575 N CAHUENGA BLVD W #222	90068	4	159B177   196	2425008023	C2-1VL, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			Verifications in Progress	05/14/2013 12:00:00 AM	PIN	34.13362778	-118.35843173	restamp of approved set. contractor lost approved set. notice emergency lighting was not sufficient. correction issued to fix emergency lighting. pending approval. T.I. change OF USE FROM OFFICE TO YOGA STUDIO.  Plan check for energy with emergency lighting. B Occupancy. load is less than 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35381	17041-10000-12120	7320 WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	33.94135	-118.42357	PC FOR ENERGY. INSTALATION OF 2 LIGHT POLES AND 6 NEW FIXTURES. AFFECTED AREA 20500 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35382	15041-10001-27587	22524 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	33.8214	-118.30137	rooftop solar installation 1.72kW AC. Permit under 15041-90000-27587	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35383	18041-20000-19623	3501 S TROUSDALE PKWY 3rd Floor	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.02194	-118.28455	Plan check for Title 24 only in existing space corridor lighting. Total area: 320 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35384	07041-20001-11304	10155 N CANOGA AVE	91311	12	204B105   476	2747010022	[T][Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM	02/29/2012 12:00:00 AM		Permit Finaled	05/08/2012 12:00:00 AM	ADDRESS	34.25509	-118.59748	replace stolen wires from service and feeders drop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35385	19041-20000-46920	13263 N WHEELER AVE UNIT 1	91342	7	225B157   750	2512010005	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35386	17041-20000-36035	17801 W VENTURA BLVD	91316	5	171B129   290	2162012008	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.16317	-118.52051	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan hceck for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35387	10041-10002-14655	5757 W WILSHIRE BLVD #106	90036	4	135B177   470	5508015004	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM			PC Approved	12/08/2010 12:00:00 AM	ADDRESS	34.06259	-118.35341	REVISION TO THE APPROVED PLAN. ADD EMERGENCY LIGHTS TO AN EXISTING EMERGENCY CIRCUIT. (((((((((((T.I. to existing building for new Starbucks.  Install general/emergency lighting.  Plan check for energy only. ))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35388	19041-30000-25473	2049 S CENTURY PARK EAST 39TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	ENERGY PC FOR T. I. RENOVATION TO PUBLIC Restroom.  AREA 410SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35389	13041-10000-33139	1951 S LOS ANGELES ST	90011	9	123A207   242	5127025016	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.02933	-118.26462	TITLE 24 PART 6 ENERGY; SCOPE OF WORK IS FOR REMOVING (E) HID FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. ALL WORK WILL BE INTERIOR. 13 TOTAL UNITS. PROJECTED AREA IS AROUND 7718 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35390	17041-20002-26310	2429 N LYRIC AVE	90027	4	150B201  1115	5433009005	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.10515	-118.27605	11/28/17changes to an approved set of plans.  changes include new modules sc325 and addition of (2) AC disconnects for battery back up.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35391	18041-20000-08560	20444 W VIA CELLINI	91326	12	219B109   258	2701055008	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.29443	-118.58072	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.05 KW + ENERGY STORAGE SYSTEM 27KWH.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35392	18041-10002-21550	1047 S WINDSOR BLVD	90019	10	132B189  1130	5082019021	R1-1-HPOZ	Central	Wilshire	Olympic Park		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.05437	-118.32621	Install (1) ESS system, 13.5 kWh<<Install new PV1 rooftop solar system 7.6 kW AC (25) modules, (1) inverter under separate application#>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35393	13041-10000-27349	2021 W PICO BLVD	90006	1	129A201   201	5136023030	C2-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Public Safety Only			10/02/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Issued	10/08/2013 12:00:00 AM	ADDRESS	34.04709	-118.28194	new fire warning system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35394	11041-20000-16586	17500 W BURBANK BLVD	91316	12	174B129   855	2254037019	RA-1	South Valley	Encino - Tarzana	Encino		1390.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	08/08/2011 12:00:00 AM		Permit Finaled	10/18/2011 12:00:00 AM	ADDRESS	34.17213	-118.51506	Plan check replace existing 1200A service and new switchboard. All loads are existing to remain. Existing panels suitable for new fault current.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35395	14041-10000-31730	734 N HENRY FORD AVE	90744	15	030B213   112	7440002034	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	33.78073	-118.24147	Installation of new equipment on an open air compression skid which power 2 hydrogen compressors and a hydrogen purification unit.  Conduit only variance has been filed as a misc. permit for inspection on supp application 14041-10001-31730.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35396	18041-20000-14492	9810 N ZELZAH AVE	91325	12	201B129   126	2755001019	(Q)R3-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.24898	-118.52309	PV2THIS IS A (2) PART SYSTEM, ROOF MOUNTED AND GROUND MOUNTED SYSTEM.INSTALL GROUND MOUNTED PV SYSTEM SIZED 410KW WITH (7) 50KW INVERTERS (1) 60KW INVERTER AND (1554) MODULES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35397	12041-20000-10692	5525 N ETIWANDA AVE	91356	3	174B125   518	2160011026	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Closed	03/24/2014 12:00:00 AM	ADDRESS	34.17048	-118.53094	Medical office TI. 5 new branch circuits. Plan check for power. Plan check for energy on supplemental, 12041-20001-10692.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35398	19041-10000-20740	444 W UNIVERSAL HOLLYWOOD DR 11 story-Hi-Rise	91608	4	162B177   616	2424044037	[Q]C2-1-SN	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM	06/25/2021 12:00:00 AM		Issued	06/25/2021 12:00:00 AM	PIN	34.1391226	-118.35899994	Plan check for power and energy for New 11 story high-rise office building with parking garage. Service size is 4160V, 1200A ,3ph ,4w. Total affected area is 820,812sf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35399	15041-10000-29916	9350 N GLENOAKS BLVD	91352	6	198B173    53	2538011009	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Expired	10/05/2017 12:00:00 AM	ADDRESS	34.23869	-118.37549	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (STORAGE WAREHOUSE). SCOPE INCLUDES REPLACING  HID LIGHTING FIXTURES WITH NEW LED FIXTURES. TOTAL AREA IS 3664 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35400	14041-10000-33851	12876 W HAMMOCK LANE	90094	11	102B157   397	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	33.97463	-118.41997	Standard plan PV1 3.8KW roof-mounted system including (1) Solaredge SE3800A-US inverter, (17) Trina solarTSM-250 and Solaredge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35401	15041-20001-09716	6320 N TOPANGA CANYON BLVD #1605	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM			PC Approved	09/15/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	(9/15/2015) - Changes to approved set.  Clarification of home runs in break room, inclusion of split bus details on panel schedule, and includion of short-circuit current on single line diagram.  All changes clouded with delta 2.         Plan check for power and energy for WellsFargo Bank first time tenant. Total area: 2544 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35402	19041-10000-26378	16603 W SAN FERNANDO MISSION BLVD	91344	12	210B137   363	2682015001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.27222	-118.49368	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35403	15041-10000-28872	1462 E 47TH ST	90011	9	112-5A211 324	5107013005	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.20	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.00095	-118.24841	PV1, ROOF MOUNTED. (13) MODULES (1) INVERTER. TOTAL SIZE 3KW. (13) KYOCERA #KU2656ZPA(1) ABB # PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35404	14041-20000-20509	1601 N CASALE ROAD	90272	11	132B133    47	4425001009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.06106	-118.50371	Plan check for power on a new single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35405	19041-10001-44812	1261 S STONER AVE 1-8	90025	11	129B145   887	4263008009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Apartment			11/01/2019 12:00:00 AM			Reviewed by Supervisor	11/20/2019 12:00:00 AM	ADDRESS	34.04711	-118.46065	***Expedite Fee*** NEW ROOF MOUNTED 8.96 KW (DC) PV SYSTEM WITH 32 PV MODULES WITH ENPHASE MICROINVERTERS ON AN APARTMENT BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35406	14041-10000-00784	6426 W LA PUNTA DR	90068	4	153A187   186	5576009112	R1-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.11387	-118.32917	PV1.  Install 9.43 kW AC roof-mounted PV system, interconnect with main service panel.  Microinverter: Enphase M215-60-2LL-S22.  45 modules: Trina Solar TSM-240 PA05.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35407	16041-20000-07985	300 E 42ND ST	90011	9	114A205   145	5113021004	C2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.00737	-118.27006	PV1.  Install 3.8 kW AC roof-mounted PV system.  (16) modules with (1) 3.8 kW inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35408	13041-10001-33150	8118 N JUMILLA AVE	91306	3	189B117   130	2106014018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.21736	-118.56324	Expedite RSES plan check per applicant request.[][]PV1, Install 9 kw DC roof-mounted solar array, interconnect with the service panel.(2)Transformerless inverter(s):Solaredge SE3000A-US and solaredge SE6000A-US. (36)modules Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35409	12041-10000-08864	17029 W LASSEN ST	91325	12	201B133   134	2694008030	(T)RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	34.25042	-118.50332	roof mounted photovoltaic sytem on the roof of a building, with enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35410	19041-10000-52371	5750 W WILSHIRE BLVD 2nd Flr	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Approved	06/24/2020 12:00:00 AM	ADDRESS	34.06227	-118.3542	Interior T.I. to Office area on the 2nd Floor. Plan Check for Power & Energy. Added Load > 400Amp. Affected area: 83,468 SFT. Building Permit: 19016-100000-40166	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35411	17041-30000-22032	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	33.98095	-118.40764	Plan check for Title 24 only. Project site is (2) ground-level elevator lobbies in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,236 sq. ft.Note: Building permit has been issued under 17016-10000-09161	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35412	10041-10000-08915	6675 W HOLLYWOOD BLVD	90028	13	148-5A185  90	5547009006	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	06/23/2011 12:00:00 AM	ADDRESS	34.10173	-118.33567	T.I. to existing building.  New electrical installation.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35413	16041-20000-28731	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM			Reviewed by Supervisor	08/26/2016 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for power only. Project site is an existing commercial building (commercial printing services). Project scope is new electrical distribution equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35414	14041-20000-20786	9301 N TAMPA AVE Ste 135	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM			Corrections Issued	08/01/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI to (E) commercial restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35415	16041-10001-30335	9415 S CENTRAL AVE	90002	9	094-5A209 446	6049030004	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM			PC Approved	04/28/2017 12:00:00 AM	ADDRESS	33.95094	-118.25488	CHANGE TO APPROVED SET. PER BUILDING SCOPE, BUILDING IS ONLY 1 STORY. UPDATED PLANS AND T24 TO REFLECT SINGLE STORY. PC ONLY, PERMIT ALREADY ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35416	18041-10000-26385	12204 W VENTURA BLVD	91604	2	162B165   220	2369004038	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM			PC Info Complete	09/05/2018 12:00:00 AM	ADDRESS	34.14303	-118.39869	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE : EXISTING BEAUTY SALON TO RETAIL/MEDICAL OFFICE.BUILDING PERMIT # 18016-10000-22427	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35417	16041-30000-23029	1350 S SEPULVEDA BLVD	90025	5	129B149     8	4324017904	OS-1XL	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.05226	-118.44802	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 15860.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35418	16041-10000-20514	1555 E 53RD ST	90011	9	108B213   132	5105002029	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	33.99493	-118.24589	PV SYSTEM WITH CENTRAL INVERTER 3.8KW AC USING 10 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35419	14041-20001-05230	5800 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	ADDRESS	33.97397	-118.41979	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35420	15041-20000-00962	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM			PC Info Complete	01/13/2015 12:00:00 AM	ADDRESS	33.98722	-118.47211	TI TO AN EXISTING RESTROOM TO A COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  TOTAL SQUARE FOOTAGE 418.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35421	19041-20000-12830	6310 W SAN VICENTE BLVD #200	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM			PC Info Complete	04/09/2019 12:00:00 AM	ADDRESS	34.06084	-118.36757	Plan check for Title 24 energy only in existing space Tenant Improvement. Total area: 3853 sq ft B#19016-40000-03028	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35422	16041-10000-43247	11715 N SHOSHONE AVE	91344	12	213B129   415	2601069008	RE40-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.28237	-118.51671	PC FOR PV SIZE 10440 AC  ROOF MOUNTED SINGLE FAMILY DWELING.INCLUDES: 29  INTIGRATED AC MODULES SPR-X22-360-C-AC1 NEW LOAD CENTER 125A AND A PV MONITOR SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35423	18041-10000-12372	6667 W HOLLYWOOD BLVD	90028	13	148-5A185 115	5547009003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	07/13/2021 12:00:00 AM	ADDRESS	34.10173	-118.33536	PC FOR ENERGY AND POWER FOR CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES NEW PANELS, LIGHTING, RECPTICALS AND NEW SERVICE (800A). TOTAL AFFECTED AREA IS 1510 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35424	12041-10000-13891	2860 E OLYMPIC BLVD	90023	14	120A221   139	5170026008	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM			Corrections Issued	06/15/2012 12:00:00 AM	ADDRESS	34.0224	-118.21593	Change to outdoor lighting.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35425	17041-10000-06286	19850 W NORDHOFF PL	91311	12	198B113   155	2761001812	MR2-1, R1-1	North Valley	Chatsworth - Porter Ranch, Reseda - West Van Nuys	Chatsworth, Reseda		1133.03	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.23573	-118.56604	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  8100 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35426	16041-20000-42050	272 E WAYLAND ST	90042	1	153A229    17	5484030004	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	Yes	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.11556	-118.18833	PV1.  Install 3.5 kW AC roof mounted, grid tied PV system.  Microinverters with (14) modules.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35427	09041-10001-18204	3025 S FIGUEROA ST	90007	9	120A203    13	5123010004	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			01/13/2010 12:00:00 AM			PC Approved	01/13/2010 12:00:00 AM	ADDRESS	34.0245	-118.27873	Supplemental is for changes to previously approved plans.  Changes were made to unit configurations, T-24, and wiring layout.  P/C is for Power and Energy. :: NEW 3-STORIES   34 UNITS 9-TYPES APARTMENT BUILDING WITH ABOVE GRADE PARKINGSPACES  VARIANCE HAS BEEN FILED TO SEPARATE THE FA PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35428	13041-20000-27383	12264 W GAGER ST	91331	7	210B165    80	2532025017	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.27553	-118.40035	PV1 MICROINVERTER PLAN. TOTAL SYSTEM SIZE 1.29KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35429	18041-10000-15093	1667 N NORTH MAIN ST	90012	1	136-5A219 173	5409003018	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.06769	-118.2262	Install a new Fire Alarm System in a new Gallery.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35430	18041-10000-04272	11336 N CORBIN AVE	91326	12	213B117   422	2701004025	(T)RE11-1-H, [T]RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.27795	-118.56396	PC for T24 only for replacement of outdoor metal halide fixture with new LED fixtures. Total area 101050qft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35431	16041-10000-44543	22536 W SOUTH SUMMIT RIDGE CIR	91311	12	198B097    60	2727022081	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Issued	12/20/2016 12:00:00 AM	ADDRESS	34.23937	-118.61823	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.6KW AC USING 2 CENTRAL INVERTERS WITH POWER OPTIMIZERS. TOTAL OF 54 MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35432	16041-20001-37242	10644 W TUXFORD ST	91352	7	195B177     7	2544028009	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	34.23575	-118.36315	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 9.8 kWac and consists of (30) AC modules and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35433	15041-20000-23747	4475 N LIBBIT AVE	91436	5	168B137   716	2284009008	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.15337	-118.49346	$0 permit fee due to senate bill 1222 from 2012Plan check for a PV1 roof-mounted PV system. System size is 12.6 kWac and consists of (2) inverter, (59) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35434	12041-20000-28815	20453 W MALDEN ST	91306	12	192B109   123	2781008013	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.22545	-118.57921	New Enphase, rooftop photovoltaic system for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35435	11041-10000-15485	10811 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	09/28/2011 12:00:00 AM	ADDRESS	34.26635	-118.52366	NEW FIRE ALARM SYSTEM FOR AN EXISTING RITE-AID.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35436	13041-20000-12703	12231 W HUSTON ST	91607	5	168B165   202	2356011014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.15951	-118.39972	New Ungrounded Photovoltaic System for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35437	10041-10000-08174	2726 N GRIFFITH PARK BLVD	90027	4	151-5A205 236	5433026037	C4-1D, P-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	12/02/2010 12:00:00 AM	ADDRESS	34.10748	-118.27292	Change from retail to beauty salon.  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35438	12041-20000-28894	3640 S STONER AVE	90066	11	114B157   578	4234019007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.00987	-118.4298	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35439	14041-20000-27735	5821 N SALOMA AVE	91411	4	174B149   197	2243015017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.17644	-118.45868	PV1 SFD. TOTAL SYSTEM SIZE 5.16KW AC USING ENPHASE MICROINVERTER. USING STANDARD PLAN. ENPHASE M215. TOTAL OF 24 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35440	18041-10000-45102	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	T-24 ENERGY ONLY TI FOR AN EXISTING RETAIL STORE. (NO CHANGE OF USE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL EFFECTED AREA IS 1385 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35441	14041-20000-27171	5900 W WILSHIRE BLVD 17th Floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.06237	-118.35809	TI to (E) commercial office space.  Additional distribution equipment for new server room and other IT equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35442	18041-20001-35639	2917 W TEMPLE ST	90026	13	139-5A203 445	5156014010	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village	YES	1958.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.07449	-118.27896	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 21.08 kWdc/20 kWac and consists of (2) inverters, (62) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35443	18041-10000-26023	601 S FIGUEROA ST 49TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 14730 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35444	13041-20000-19780	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Expired	09/22/2015 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for power for fuel cell installation. Fees to be verified during plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35445	18041-20000-02848	962 N SOMERA ROAD	90077	5	144B149   333	4369034012	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.08764	-118.45671	PLAN CHECK FOR POWER FOR (N) 1-STORY SFD W/ BASEMENT & ATTACHED GARAGE. SERVICE SIZE = 600A WITH ASSOCIATED LOADS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35446	15041-10000-41322	9944 N O'MELVENY AVE	91331	7	201B161   142	2622020002	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.25075	-118.41916	PV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC USING CENTRAL INVERTER SYSTEM AND 17 MODULES TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35447	18041-20001-29916	474 W VISTA GLORIOSA DR	90065	1	144A221    52	5452013009	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM			PC Approved	08/20/2018 12:00:00 AM	ADDRESS	34.09056	-118.21881	expeditepv1install roof mounted pv system sized 10 KW AC interconnected with msp.(40) silfab sla 300 modules(40) enphase energy IQ7 microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35448	16041-10000-41973	12615 W BEATRICE ST	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	33.98049	-118.41636	Plan check for fire alarm system in commercial building. Total fire alarm devices: 114 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35449	19041-20000-44193	9545 N RESEDA BLVD	91324	12	201B125   431	2763036008	(T)(Q)C2-1VL, C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	34.2439	-118.53634	Plan check for service upgrade to 600A, 800 distribution board .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35450	19041-20000-05906	4725 N EL CABALLERO DR	91356	3	168B121   335	2176030032	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.15585	-118.54571	PV1.  Install 13 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (40) modules with 10 kW rated string inverter and (2) 13.5 kWh battery storage units.$7.47 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35451	15041-20000-31343	444 S FLOWER ST Suite 180	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is an existing commercial space in a high-rise building. Project scope is a tenant improvement. Total lighting area = 470 sq. ft. Note: Building permit has been filed under application 15016-10000-03397	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35452	19041-10000-15344	8501 N FALLBROOK AVE SUITE 270	91304	12	192B097   587	2005022006	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.22478	-118.62651	Tenant improvement in (E) commercial office building.  Plan check for energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35453	13041-20000-18966	150 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Expired	01/09/2018 12:00:00 AM	ADDRESS	34.07452	-118.32343	800 amp service upgrade and tenant improvement to an existing commercial retail and office space.  Overhead service drop, site is in a Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35454	14041-10000-32402	1537 N NORFOLK ST 6th Floor	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.06138	-118.20223	9,330 sq. ft. outpatient clinic remodel.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35455	11041-10000-13839	555 S FLOWER ST 6th floor	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM			PC Approved	07/05/2011 12:00:00 AM	ADDRESS	34.05048	-118.25755	T.I.  Remodel of office space on the 6th floor of high rise building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35456	16041-20001-23163	1424 E NEWTON ST	90021	14	121-5A213 322	5130012020	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.0258	-118.24404	Title 24 Part 6 plan check per inspection corrections.  1,168 SQ FT.  Interior TI and change of use from warehouse into a sound studio and office.(((REWIRE AND ADD CIRCUITS TO EXISTING SERVICE PANEL)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35457	19041-10001-04268	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM			PC Approved	10/17/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED. CHANGES INCLUDE ADDING REPLACING PANEL FOR SPLIT BUS AND REVISING LIGHTING FLOOR PLANS. NOTE: PLAN CHECK ONLY. PERMIT PAID UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35458	18041-20000-20276	16143 W HART ST	91406	6	183B141   324	2224010042	QMR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.19768	-118.48502	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35459	14041-10000-27435	3615 S SAN PEDRO ST	90011	9	117A207   312	5121012004	C2-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.01341	-118.26682	Installation of roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35460	13041-10001-36298	6539 N LEDERER AVE	91307	12	180B093   523	2036023018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.18939	-118.63922	Expedited RSES plan check per applicant request.{{PV1, Install 9 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US and Solaredge SE 5000A-US. (36) Modules: Trina Solar TSM-250PA05.18.(36) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35461	11041-10000-19900	9301 N TAMPA AVE #90	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/30/2011 12:00:00 AM			PC Approved	01/05/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for T-24 lighting compliance and emerg. and exit lights.(INTERIOR TENANTIMPROVEMENT OF AN EXISTING RETAIL STORE INVOLVING NEW STORE FRONT, NEW LIGHTING, NEW FINISHES & MILLWORK)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35462	16041-30000-36335	1731 N SUMMITRIDGE DR	90210	5	147B157    52	4355002021	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM			PC Approved	12/21/2016 12:00:00 AM	ADDRESS	34.10227	-118.42034	Power plan check.  New single family dwelling with 600 amp service and three subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35463	18041-10000-30093	1999 S AVENUE OF THE STARS #2300	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Issued	10/19/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PC FOR T-24 ENERGY ONLY FOR OFFICE TI FOR MORGAN STANELY ON THE 23RD FLOOR. TOTAL AFFECTED AREA 12282 SQ.FT SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. B#18016-10000-25297	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35464	13041-20000-31896	12841 W NORTH SEAGLASS CIR	90094	11	102B161  1223	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	33.97468	-118.41882	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35465	15041-20000-03177	10739 W STALLION RANCH ROAD	91040	7	204B177   260	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	34.25715	-118.36484	New GROUND MOUNTED PV system, interconnect with DWP transformer (Feed-in Tariff) IN RESIDENTIAL PROPERTY.System size: 30.88kW. Ungrounded system.(128) EnPhase M215-IG microinverters with (128) 250W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35466	19041-20000-29801	21300 W VICTORY BLVD 4th 5th-flr	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.18813	-118.59618	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35467	16041-20000-00697	5200 W WILSHIRE BLVD	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.06194	-118.3435	Plan check for Title 24 only for T.I. in corridor area:460 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35468	15041-20000-06435	10161 W VALLEY SPRING LANE	91602	4	165B181   452	2424035006	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.14691	-118.35223	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (48) modules, (1) inverter, and (1) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35469	19041-20000-36609	22655 W MARLIN PL	91307	12	183B097   489	2024024012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.19699	-118.62085	PV1.  Install 4.875 kW DC / 4.124 kW AC PV system with (15) modules and (1) inverter (SE3800A) addition to (E) PV system and 19.6 kWh energy storage system with associated distribution.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35470	18041-10000-19576	19191 S VERMONT AVE 5TH FLR.	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR TI IN AN OFFICE BUILDING (HIGH RISE)5TH FLOOR EXISTING CORRIDOR, ELEVATOR LOBBY AND RESTROOM RENOVATION.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 2200 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35471	14041-10000-04855	843 N EDGEMONT ST	90029	13	144B197  1366	5538014021	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Expired	05/03/2016 12:00:00 AM	ADDRESS	34.08699	-118.29621	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0 KWAC. ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35472	10041-20001-00959	8530 W VENICE BLVD	90034	10	123B173   500	5065007034	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/21/2011 12:00:00 AM	ADDRESS	34.03424	-118.37908	Plan check to approved plans. Changes to modules and inverter types 9.68KW Photovoltaic system on commercial bldg. Checked under 2008 NEC. Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35473	19041-10000-20862	6820 W ROMAINE ST	90038	4	144B185   975	5532012026	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Issued	07/01/2019 12:00:00 AM	ADDRESS	34.08879	-118.33925	Power plan check for wood shop (updating panels from nema R to 3R). no new load . existing 1600A, 120/208V, 3ph, 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35474	14041-10000-12539	4044 S REDWOOD AVE	90066	11	108B153   647	4230009054	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	33.99221	-118.44123	Install new fire alarm system for 22 unit apartment building56 new devices and one fire alarm controll pannel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35475	16041-10000-15025	2300 W OLYMPIC BLVD	90006	1	130-5A201 147	5136015030	C2-1, C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.05211	-118.28259	PV1 5KW DC ROOF MOUNTED SOLAR ARRAY, SINGLE FAMILY. 20 MODULES ( RENOGY 250) WITH 20 MICRO INVERTERS ( ENPHASE M250-60-2LL-S22).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35476	12041-20000-23641	3658 W 3RD ST	90020	4	135B197   188	5502005053	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	12/17/2012 12:00:00 AM		Permit Finaled	07/15/2013 12:00:00 AM	ADDRESS	34.06889	-118.2959	New electrical system to supply  a new coinj op laundry mat, and to supply existing panels at a restaurant.  T-24 lighting plan check for laundry only.  The site is located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35477	18041-10000-23292	5112 W HOLLYWOOD BLVD	90027	13	148-5A195 108	5544013069	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.10159	-118.30108	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35478	15041-20001-37188	4849 N VAN NUYS BLVD	91403	4	169-5A151  98	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM			PC Approved	05/02/2016 12:00:00 AM	ADDRESS	34.15918	-118.44892	05/02/2016 Changes to an approved set of plans. Changes include the relocation of receptacles and light fixtures due to structural changes. All changes have been clouded. Everything else has remained the same.*****Previous Work Description*****TI to existing commercial building. Medical office TI. Plan check for power and energy. Total sqft. 3,900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35479	11041-10000-11784	428 E WASHINGTON BLVD	90011	9	121-5A207  18	5127019015	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	06/08/2011 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	PIN	34.02883464	-118.26080424	TI, TO AN EXISTING SINGLE STORY BUILDING IN A SHOPPING CENTER.  SINGLE RETAIL SPACE IS BEING SPLIT INTO TWO SEPERATE UNITS.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35480	18041-10000-30616	314 N WILMINGTON BLVD	90744	15	027B205   169	7417017032	[Q]C1.5-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.77252	-118.27342	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35481	14041-20000-06213	5725 E BUENA VISTA TER	90042	14	159A229   199	5480015010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.12982	-118.1931	pv1 single family dwelling. total system size 4.3kw AC using microinverter enphase m215. using standard plan. using 20 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35482	15041-20000-14731	6250 N TOPANGA CANYON BLVD F Ste 1580	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for 1st time tenant. Interior T.I. of retail store[VARGAS] within an existing shopping center to include new accessible employee restroom, new changing rooms and new storage room. Total area:1880 sq ft. SUITE 1580	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35483	16041-10000-36036	13854 N CRANSTON AVE	91342	7	228B153   111	2503020020	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.324	-118.4345	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(16)MODULES-CANADIAN CS6X-320P(1)INVERTER-GROWATT-5000MTL-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35484	18041-10000-06113	3945 S CRENSHAW BLVD	90008	10	117B185  1159	5032002059	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.01348	-118.3355	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35485	18041-20000-31138	310 N CARMELINA AVE	90049	11	135B141   814	4405003001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.06215	-118.48478	Plan check for installation of 600A  Automatic Transfer Switch(ATS) for new generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35486	18041-10000-43886	15019 W ROSCOE BLVD	91402	6	192B145   390	2653024016	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.22163	-118.46002	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35487	13041-10000-15288	3620 S MCCLINTOCK AVE 2ND FL-SGM  BLDG	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.0213	-118.28935	remodel offices (Suite 223) and data room ( suite 283)including  non required stand by generator,feeders and other loads	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35488	16041-20000-00480	3601 S WATT WAY STE.315	90089	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.02113	-118.28752	Plan check for Titlt 24 only in existing space USC office Grace Ford Salvatori Hall(GFS) 3rd Floor. Total area: 1,622 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35489	18041-10000-41051	427 W FLORENCE AVE	90003	8	102B201   802	6013028035	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	33.97483	-118.2815	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35490	13041-10001-26496	8959 N NEVADA AVE	91304	12	195B101    37	2010021009	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.23373	-118.60746	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. 1STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE: 13 KW.(52) RENESOLA SOLAR MODULES(2) SOLAR EDGE SE6000A INVERTERUPGRADE TO 225 AMP PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35491	16041-20000-05212	307 N WILMINGTON BLVD 4A	90744	15	027B205   209	7417010905	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	33.77243	-118.27378	Plan CHECK ONLY, Plan check for New 13 residential buildings with total of 88 units, include new services, site lights, Community Bldg. Total area: 2000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35492	17041-10000-35210	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	02/24/2018 12:00:00 AM	ADDRESS	34.21445	-118.48429	TITLE 24 PLAN CHECK FOR OFFICE TI ((2800 SF); TI CONSISTS OF OFFICES SPLITTING INTO TWO FOR EACH EXISTING SPACE; ONE OFFICE WAS CONVERTED INTO A SMALL RESTROOM AND A BREAK ROOM). TOTAL AFFECTED AREA = 1902 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35493	16041-10000-42993	21494 W VICTORY BLVD	91367	3	180B105    57	2146005186	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.18794	-118.59887	PC FOR FA SYSTEM - USING 58 DEVICES AND 5 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35494	17041-10000-37834	10275 N GLENOAKS BLVD	91331	7	204B165   106	2537018032	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.25681	-118.39527	TITLE 24 ONLY, RELACE OUTDOOR EXISTNG FIXURES WITH LED FIXURES, TOTAL SQUARE FOOTAGE 13200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35495	18041-10001-36496	13005 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.14571	-118.41627	"Suppl for an approved set, change includes delta ""D"", ""F"",""H"",""G"",""I"",""J"",""K"". Also, a change of address permit revising from 13003 W Ventura Blvd to 13005 W Ventura Blvd. B#18016-10001-30914"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35496	13041-10000-05723	8425 N LAUREL CANYON BLVD	91352	6	192B165   289	2633006018	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.22407	-118.39842	PLAN CHECK FOR POWER AND ENERGY. CONVERTING 3 TENANT RETAIL SPACES INTO 1 LARGE TENANT SPACE (99 CENT STORE). TOTAL SQRFT:15319. USING EXISTING SERVICE BUT UPGRADING PANELS. ALL NEW PANELS HAVE ALL NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35497	15041-20000-14376	11731 W BARRINGTON CT	90049	11	135B145   634	4401007008	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM			PC Approved	05/13/2015 12:00:00 AM	ADDRESS	34.06427	-118.46988	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement (not first time tenant). Total lighting area = 625 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35498	12041-20000-00168	16721 W VENTURA BLVD	91436	5	168B137   259	2259011036	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	01/11/2012 12:00:00 AM	ADDRESS	34.15868	-118.49763	TI: CREATE 20' X 34' OFFICE WITH IN (E) AUTO DEALERSHIPEnergy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35499	11041-10000-15698	637 S LORNA LANE	90049	11	132B145   331	4401013009	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Expired	09/06/2023 12:00:00 AM	ADDRESS	34.05602	-118.46912	New two story single family residence.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35500	16041-30001-24355	20743 W CLARK ST	91367	3	174B109   683	2151031052	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM			PC Approved	07/18/2016 12:00:00 AM	ADDRESS	34.1689	-118.58423	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition size is 3 kWac for a total system size of 6 kWac. Addition consists of (1) inverter, (15) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35501	14041-20000-31655	8215 N VAN NUYS BLVD 104 &108	91402	6	192B149   484	2210010023	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.22037	-118.44896	T.I. on ground floor CONSULTATION office of 3 story building. pc for power and energy. NO  PATIENT CARE AREAS PER APPLICANT, ONLY CONSULTATION. DISAGGREGATION OF LOAD NOT REQUIRED PER APPLICANT DUE TO TENANT (PANEL NP) MAX  LOAD ONLY 48KVA. VARIANCE HAS BEEN SUBMITTED TO ADD LOADS TO EXISTING INSTALLATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35502	17041-10000-14667	2931 N GILROY ST	90039	13	150A211    51	5437029008	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.10695	-118.25119	Title 24 plan check.  Change of use with new lighting from retail to brewery.  Total area = 4,000 sq. ft.      Building permit #16016-10000-25694	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35503	12041-10000-09456	2250 E ALCAZAR ST bsmnt	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM			PC Approved	04/25/2012 12:00:00 AM	ADDRESS	34.06307	-118.2	remodeling existing room to be a training roomplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35504	15041-10000-04437	6255 W SUNSET BLVD Suite 840	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for T-24 only. T.I. Total area: 2361 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35505	11041-10000-27553	1534 N MCCADDEN PL	90028	13	147A185    20	5547020031	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.09903	-118.33746	Plan check power and energy for restuarant TI. New 600A service electrical system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35506	13041-10000-35840	714 W 27TH ST USC-ECTC	90007	9	121-5A203  36	5123016021	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.02818	-118.27938	"NEW FIRE ALARM SYSTEM FOR ""USC EARLY CHILDHOOD TRAINING CENTER"" IN 2-STORY BUILDING. BUILDING IS NOT SPRINKLERED; BUILDING AREA APPROX. 12,817 SQ FT. (1) FIRE ALARM CONTROL PANEL, (1) ANNUNCIATOR PANEL."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35507	17041-20000-11995	400 N OAKHURST DR	90210	5	138B169   939	4335006035	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.07549	-118.39071	PV2.  Install roof mounted grid tied PV system sized 46kW.  $0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35508	15041-10000-33517	13274 W VAUGHN ST	91331	7	213B157   292	2524024003	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	PIN	34.28155076	-118.42216255	PV1. NEW ROOF-MOUNTED SOLAR SYSTEM ON AN EXISTING HOUSE. TOTAL SYSTEM SIZE IS 3.06KW. (12) MODULES-CANADIAN SOLAR CS6P-255P(1) INVERTER- PVI-3.0-OUTD-S-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35509	13041-10000-25179	925 E PALMS BLVD	90291	11	111B145  1506	4241009021	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	33.99611	-118.45981	PV1 3.49KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: PVI-3.6-OUTD-US] [( 16) MOD: ALEO SOLAR S18U250]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35510	19041-20000-10992	3165 S CURTS AVE	90034	10	123B169  1341	4312010012	RD2-1-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Re-Activate Permit	05/27/2020 12:00:00 AM	ADDRESS	34.03022	-118.38806	Plan check for a PV1 roof-mounted PV system. System size is 5.28 kWdc/5 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35511	13041-10005-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	2/11/16CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 31 TO REFLECT THE FIELD. CHANGES INCLUDE THE ADDITION OF SHOW RECEPTACLES AND EXIT SIGNS. (((REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  ((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35512	15041-20000-05697	8707 N SHIRLEY AVE	91324	12	195B117   178	2783025802	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.22881	-118.55807	Plan check for power and title 24 (energy).  Total area = 445 sq. ft.New 800 A distribution board, addition of 800 A ATS secion to existing switchgear, and other loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35513	14041-10000-12648	5844 N MURIETTA AVE	91401	2	174B153   120	2246015007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.17699	-118.4387	PV1, INSTALL  5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER AND WITH OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35514	14041-10001-24763	380 WORLD WAY T 03	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Modification to approved set, delta 2 and 3 revisions only.  Revised fixture schedule and Title 24 forms.  Additonal revisions not related to scope of Title 24 plan check - revised load schedule and panel schedule.  Affected sheets: T-24-1, E-2.0, E-2.1(((Title 24 plan check only.  Total area = 773 sq. ft.TI to airport terminal kiosk.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35515	14041-10001-03180	904 W DICKSON ST	90292	11	105B149   314	4229009040	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	33.9869	-118.45048	Expedited plan check per applicant request.  (((PV1.  Install 3.50 kW roof-mounted PV system, interconnect with main service panel.  14 modules: Rensola JC250M-24/Bb.  Transformerless inverter: SolarEdge SE3800A-US.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35516	14041-20002-34421	1445 N LA BREA AVE	90046	4	147B181   696	5548017400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM			PC Approved	10/23/2015 12:00:00 AM	PIN	34.09762485	-118.34442446	[[[10/23/15 CHANGES TO APPROVED SET OF PLANS AND CHANGE OF ADDRESS PERMIT FROM  7100 SUNSET BLVD TO 1445 N LA BREA  AVE. DELTA 1 CHANGES ONLY ADDITION OF ONE BATHROOM. REDUCTION OF OUTDOORLIGHTS AND MODIFICATION OF SERIES RATED BREAKERS TO SQUARE D.  ]]]]Changes to an approved set of plans. Changes include the addition of a 400-amp meter section in order to backfeed an existing 400-amp panel. *****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. NEW RETAIL BUILDING. 1 STORY. [ TAP ON UGPS DWP JURISDICTION PER APPLICANT, {CONDITIONAL APPROVAL  PER DWP UTILITY SERVICE REPORT FOR ISC LESS THAN 42,000}).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35517	11041-10000-01307	5757 W WILSHIRE BLVD # 348	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	03/04/2011 12:00:00 AM	ADDRESS	34.06259	-118.35341	T.I. Title 24 Energy, Emergency Lighting, high rise	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35518	14041-20000-04190	3733 S CIMARRON ST	90018	8	117B189   185	5042012015	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.02007	-118.31569	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35519	14041-20001-34421	7100 W SUNSET BLVD	90046	4	147B181   696	5548017400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.09774	-118.34439	Changes to an approved set of plans. Changes include the addition of a 400-amp meter section in order to backfeed an existing 400-amp panel. *****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. NEW RETAIL BUILDING. 1 STORY. [ TAP ON UGPS DWP JURISDICTION PER APPLICANT, {CONDITIONAL APPROVAL  PER DWP UTILITY SERVICE REPORT FOR ISC LESS THAN 42,000}).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35520	18041-20000-03152	11710 N BALBOA BLVD	91344	12	213B133   166	2610002017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.28325	-118.50187	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (38) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35521	18041-10000-08919	1415 S LINCOLN BLVD	90291	11	111B145  1262	4241008016	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	33.99749	-118.46027	Plan check for T24 only, replace indoor and outdoor lighting fixtures to LED luminaires with driver. Egress lighting is not part of this scope. Total area: 17,575 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35522	13041-10000-33225	445 S FIGUEROA ST #105	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	"TITLE 24 PART 6 ENERGY WORK; TI IS FOR NEW ""JIMMY JOHN'S"" RESTAURANT IN EXISTING RESTAURANT SPACE. NO CHANGE OF USE. SCOPE OF WORK < 400A. THE STRUCTURE IS PART OF AN HIGH-RISE BUILDING. EMERGENCY LIGHTING FED VIA (E) EMERGENCY CKT. ALL WORK TO BE INDOORS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35523	14041-10000-28846	1606 N ARGYLE AVE	90028	13	148-5A189 269	5546028013	C4-2D	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.10005	-118.32503	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. AREA = 628 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35524	11041-20000-08185	2029 S CENTURY PARK EAST 37th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	08/23/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to existing high rise building of entire 37th floor.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35525	15041-10000-33052	15720 W VENTURA BLVD	91436	5	168B141   670	2283025017	C4-1L, R3-1, R3P-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.15504	-118.47562	"TENANT IMPROVEMENT TO EXISTING RESTAURANT ON FIRST FLOOR COMMERCIAL SPACE OF (E) 7 STORY BUILDING; NEW MEZZANINE 23' 7"" X 59' 6"" NEW OUTDOOR DINING AREA 927 SFPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35526	16041-20000-06642	5740 N OSTROM AVE	91316	5	174B133   232	2255018015	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.17536	-118.5066	PV1.ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35527	16041-10000-16751	8712 N NORRIS AVE	91352	6	195B173   571	2408011022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.22738	-118.36986	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(40)MODULES-SOLARWORLD SW260(40)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE10000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35528	18041-10000-13370	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. 1-STORY OFFICE WITH MEZZANINE. (15,109 SF).BUILDING PERMIT # 18016-10000-10373	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35529	16041-20000-41136	13965 W SYLVAN ST	91401	2	177B153   173	2239009008	RS-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.18451	-118.43776	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP. Derating main to 150A. 10.2kW (4.2+6) ungrounded system. (37) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35530	17041-10000-25475	8332 S OSAGE AVE	90045	11	096B173    52	4127024002	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	33.96253	-118.3786	PLAN CHECK FOR T24 ONLY - SCOPE INCLUDES REPLACING EXISTING (16) HID FIXTURES WITH NEW LED FIXTURES - TOTAL AFFECTED AREA = 17060 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35531	15041-10000-43482	5900 W WILSHIRE BLVD #2150	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.06237	-118.35809	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK IS ON THE 21ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35532	18041-10000-34579	777 S FIGUEROA ST 49TH FLOOR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Energy plan check for an office TI located on the 49th floor of a commercial building . Scope include new lighting and equipment with a total area of 14157-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35533	19041-30000-34294	333 S GRAND AVE 52nd Flr	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.05271	-118.25179	Energy pc only  for Tenant improvement to an (E) 4068 sf office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35534	14041-10000-12416	525 S HEWITT ST	90013	14	126A215    76	5163023900	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.04076	-118.2351	PLAN CEHCK FOR POWER AND ENERGY FOR EXISTING SCHOOL/OFFICE/LAB. SCOPE OF WORK IS CLOUDED DELTA4 AND HIGHLIGHTED. LTG FORMS NOT PROVIDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35535	10041-10000-15981	1100 S SAN PEDRO ST #B7 &-#015	90015	9	124-5A211 343	5132011***	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	11/01/2010 12:00:00 AM	ADDRESS	34.03515	-118.25194	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35536	14041-10000-07919	16743 W MARQUEZ TER	90272	11	129B121   711	4419014026	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.04746	-118.54603	PV1,INSTALL 10.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U & SE3800A-US-ZB-U(41) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35537	19041-10000-12805	4419 N EAGLE ROCK BLVD	90041	14	157-5A221 214	5473029018	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.12469	-118.22059	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35538	16041-20000-31901	14837 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29504	-118.45451	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35539	13041-20000-35447	17402 W CITRONIA ST	91325	12	201B129   341	2755008029	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.24553	-118.51381	Roof mounted PV system with 28KWdc.Note: Permit is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35540	16041-10000-03387	5990 N SEPULVEDA BLVD #400	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.17911	-118.46588	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR SUIITE 400. TOTAL AFFECTED AREA IS 12,728 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35541	12041-10000-14241	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	33.79173	-118.23549	Expansion of a petrochemical plant. Addition  of transformers, switchgear, switchracks, pump motors, and lighting Work will be in unclassified areas and Class  I  , Div  2 , Groups C & D	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35542	15041-20000-43477	541 S SPRING ST #130	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.04657	-118.2507	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (DONUT SHOP). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 493 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35543	16041-10000-29090	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM  STORAGE (8,289 SQFT) TO  OFFICE  IN  EXISTING TERMINAL 6 TICKETING /APRON LEVEL  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SPACE. TOTAL AFFECTED AREA IS 9430 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35544	13041-10000-33002	23445 W STYLES ST	91367	3	177B093   192	2035010028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.18405	-118.63868	PV1, Install 7.5 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(2)Transformerless inverter(s): SolarEdge SE3800A-US and SolarEdge SE3000A-US. (30) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35545	15041-10000-12012	100 WORLD WAY TERM 3	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	at lax, installation of illuminated  numeral signs to identify the terminalsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35546	15041-10000-41493	200 N NORTH MAIN ST	90012	14	130-5A213 115	5161026023	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/14/2015 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	07/07/2021 12:00:00 AM	ADDRESS	34.05326	-118.24219	FULL PC, TI TO ITA SERVER ROOM AND A NEW MECHANICAL CHILLER SYSTEM. SCOPE OF WORK INCLUDES NEW LIGHITNG, RECEPTACLES AND PANELS. TOTAL SQ. FT. 11200.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35547	13041-20000-25350	9221 N ARLETA AVE	91331	6	198B157   732	2625010002	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.23746	-118.42148	PC FOR T24 ENERGY ONLY. SENIOR REHAB CENTER. NON MEDICAL. TOTAL AREA 1353 SQ FT. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35548	16041-10002-44228	22255 W CHATSWORTH ST	91311	12	207B101    61	2723006026	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.26453	-118.61234	Changes to an approved set of plans. Changes are clouded under delta 1. Changes unclude orientation of panels for roof edge clearence - # of modules and inverter stay the sameOriginal plan check #16041-10000-44228	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35549	15041-10000-03361	6423 N ALDEA AVE	91406	6	180B133   482	2230021011	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.18754	-118.50804	PV1 8.4KW roof-mounted system including (2) Power One PVI-4.2 inverters & (30) SunPower SPS-327NE modules interconnecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35550	11041-10000-21956	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to an existing retail space in Topanga Mall.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35551	13041-20001-32479	17309 W RAYEN ST	91325	12	195B133   185	2768018006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2013 12:00:00 AM			Plans on Hold	11/25/2013 12:00:00 AM	ADDRESS	34.23232	-118.51173	((Expedite fees)) PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC. 48 MODULES AND 2 INVERTERSAPPLICATION WITHDRAWN DUE TO DUPLICATE APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35552	11041-10000-20627	1048-1058 S DOREEN PL BLDG 3	90291	11	111B149   684	4243002068	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99968	-118.45883	REPAIRS & HISTORICAL REHABILITATION  / TI OF 22 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35553	15041-10000-12422	11975 W BLUFF CREEK DR BLDG 5	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	33.98224	-118.40247	TI FOR 2-STORY YAHOO OFFICE BUILDING - BUILDING 4.  TOTAL  AREA 18548 SQ.  PLAN CHECK FOR POWER AND ENERGY.  750 KW GENERATOR TO SERVE EMERGENCY AND OPTIONAL STANDBY POWER FOR BUILDINGS 4 AND 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35554	17041-10001-38362	1601 N GENESEE AVE	90046	4	147B177   623	5551014009	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.10007	-118.35842	EXPEDITE PER APPLICANT REQUEST.INSTALL 53 NEW PV MODULES AND BATTERY BACKUP ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35555	10041-10000-14233	111 E UNIVERSAL HOLLYWOOD DR 23RD FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	12/16/2010 12:00:00 AM	ADDRESS	34.13855	-118.36112	T24 and emergency lighting plan check for a portion of the 23rd floor.  Fire life safety variance was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35556	14041-20000-24833	7010 S HOOVER ST Unit #2	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #2. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35557	18041-10000-04654	1123 W 56TH ST	90037	9	108B197   524	5002025010	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Issued	02/08/2018 12:00:00 AM	ADDRESS	33.99151	-118.29459	PC for 3kW rooftop PV solar. Installing 12 PV modules with optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35558	14041-10000-08827	515 S FLOWER ST PARTIAL-12TH FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.05134	-118.25661	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK IS ON THE 12TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35559	13041-20001-11726	12000 W IDAHO AVE	90025	11	126B145   893	4259003006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.03918	-118.46049	Modifications to approved set.  Moving of loads from one panel to another.  Separation of electric vehicle charger loads from other loads.  (((NEW FOUR STORY 34-UNIT APARTMENT BUILDING. 1600 A SERIVCE. FEES CALCULATED BY APPLICANT, FEES TO BE RECALCULATED BY PLAN CHECKER. FIRE ALARM WILL BE PULLED BY CONTRACTOR AND FIRE ALARM VARIANCE WAS FILED.)))	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35560	16041-20002-41887	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.23342	-118.3809	Revisions to approved set of plans.  Vehicle exhaust fans added.  Change of transformer conductor wiring details and welding receptacle wiring detail.  (((Plan check for power only. Upgrade existing commercial garage for maintenance of CNG fueled vehicles. Classified hazardous area.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35561	08041-30002-26291	10741 W SANTA MONICA BLVD	90024	5	129B153    23	4325030001	[Q]RD1.5-1-O, [Q]RD1.5-1VL-O	West Los Angeles	Westwood			2656.01	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM			PC Approved	03/10/2010 12:00:00 AM	PIN	34.05246051	-118.43369709	Delta P4, P5, and P6 modification to existing building.  A copy of the approved set of plans will be submitted for comparison.  All new T24 shall be submitted. Electrical Plan Check includesnew panels, lights, other loads and Title 24 energy calcs.  Variance to separate the electrical and fire alarm approvals and permits was submitted on March 26, 2009.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35562	19041-20000-44834	3291 W ROMULUS DR	90065	14	160-5A215  39	5679006023	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Issued	11/01/2019 12:00:00 AM	ADDRESS	34.1344	-118.23562	PV1 PLAN CHECK FOR 5.67 KW DC/5.2 KW AC CEC PV SYSTEM AND A 13.5 KWH ESS. SCOPE OF WORK CONSISTS OF (18) PV MODULES WITH OPTIMIZERS, A 5 KW INVERTER,A 5 KW BATTERY, AND A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35563	19041-10000-52700	4410 W JEFFERSON BLVD	90016	10	120B181   779	5046009003	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM			Reviewed by Supervisor	02/05/2020 12:00:00 AM	ADDRESS	34.02541	-118.34439	[EPLAN] PLAN CHECK FOR POWER AND ENERGY FOR NEW NON-HIGHRISE BUILDING(CORE AND SHELL). NEW SERVICE 1600A 120/2008V WITH ASSOCIATED PANELS AND EQUIPMENT WITH A TOTAL AFFECTED AREA = 27969 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35564	16041-10000-41497	1149 S HILL ST #925	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.03926	-118.26099	Plan check Title 24 only in existing space office T.I. Total area: 3,130 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35565	17041-10000-37303	12552 W SHERMAN WAY BLD C	91605	2	183B161    65	2324034019	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	07/10/2020 12:00:00 AM		Permit Finaled	11/23/2022 12:00:00 AM	ADDRESS	34.20092	-118.40719	FULL PC FOR POWER AND ENERGY FOR A NEW 3-STORY SELF-STORAGE BUILDING(BLDG 3 OF 3). NOTE: THERE ARE THREE BUILDINGS UNDER ONE SET OF PLANS. THIS APPLICATION FOR BUILDING C. SCOPE INCLUDES NEW PANELS, NEW LIGHTS AND RECEPTACLES. NEW CONNECTED LOAD > 400A. B#16010-10000-03231	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35566	16041-20000-26130	7452 N ROYER AVE	91307	12	186B097   547	2021010009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.20571	-118.62733	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35567	17041-20001-17778	4213 N PRASA ROAD	91364	3	165A109    53	2172024018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			PC Approved	07/05/2017 12:00:00 AM	ADDRESS	34.14768	-118.58858	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD. Existing 5kW pv system on home.New system is 6.6kW ungrounded. (24) 325W pv modules.Derating main breaker to 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35568	10041-10000-18070	21535 W ROSCOE BLVD	91304	12	192B105   726	2779036023	C2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Public Safety Only			09/13/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	34.21992	-118.60016	NEW FIRE WARNING SYSTEM FOR 3-STORIES APARTMENT BUILDING-81 UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35569	14041-20000-11819	924 W ELYRIA DR	90065	1	148-5A221  68	5464013022	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.10208	-118.22079	PV1.  Install 4 kW roof-mounted PV system, interconnect with main service panel.  (16) modules w/ (16) Enphase M215 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35570	16041-20000-23301	6555 W BARTON AVE 5th Floor	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.08785	-118.33475	Plan check Title 24 only in existing space office T.I. Total area: 3,570 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35571	19041-20000-47637	9515 S COMPTON AVE	90002	15	093A213    70	6048004025	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM	02/04/2020 12:00:00 AM		Permit Finaled	02/02/2022 12:00:00 AM	ADDRESS	33.95026	-118.24646	FULL PLAN CHECK, NEW 800A SERVICE, 23 SUB PANELS, 2 MAIN SWITCHBOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35572	17041-20001-17215	13113 W VAN NUYS BLVD	91331	7	210B161   744	2535018018	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.26875	-118.41881	9/26/17changes to an approved set of plans.  changes include light fixture types and energy calculations.plan check for indoor only.((((PLANCHECK FOR POWER AND ENERGY.  NEW 2 STORY COMMERCIAL BLDG. methane zone. 1076 sqft indoor common areas + 5182 sqft outdoorbuilding permit # 07010-20000-00829))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35573	16041-20001-18893	4612 N VAN NOORD AVE	91604	2	168B161   866	2362005008	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	PIN	34.15439689	-118.41461249	RSES expedited fee plan check per applicant request.  PV1.  Install 15.3 kW roof-mounted PV system.  (48) 320W PV modules with (1) 11.4 kW central inverter with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35574	15041-20000-12546	139 N COMMONWEALTH AVE	90004	13	139-5A201 319	5501006014	R4-1	Central	Wilshire	Rampart Village	YES	2111.21	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.07465	-118.28575	PV1 SFD TOTAL SYSTEM SIZE 4.7KW AC USING 22 MODULES IN TOTAL. MICROINVERTER SYSTEM. NONSTANDARD PLAN. ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35575	17041-20000-20801	281 N BENTLEY CIR	90049	5	138B149    66	4366004018	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	ADDRESS	34.07702	-118.45744	Plan check for power only. New 2-story SFD w/basement. 800A 120/240 1ph 3w service. Electrical permit fees collected under building combo permit application #14010-20000-00277.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35576	14041-10000-30031	695 S VERMONT AVE	90005	10	132B197   178	5094008026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Issued	10/29/2014 12:00:00 AM	ADDRESS	34.06016	-118.29183	Titl2 24 plan check only.  Total area = 495 sq. ft.Corridor lighting instalation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35577	11041-20000-25299	3101 S OVERLAND AVE A & B	90034	5	123B161   857	4254011039	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	ADDRESS	34.03044	-118.41627	TENANT IMPROVEMENT ON EXISTING RETAIL/MARKET GROCERY STORE. NEW INTERIOR NON-BEARING PARTITIONS, FINISHES AND MILLWORK. EXISTING CEILING TO REMAIN.energy , emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35578	14041-10000-26086	1999 W ADAMS BLVD	90018	8	123B193   477	5058015005	[T][Q]C2-2D	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.03285	-118.30872	FA NONSPRINKLERED NONHIGHRISE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35579	17041-10000-17928	14700 W GERMAIN ST	91345	7	207B149   733	2648014034	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2017 12:00:00 AM			Corrections Issued	05/30/2017 12:00:00 AM	ADDRESS	34.26176	-118.45191	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 7 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35580	17041-20000-00880	9200 N OAKDALE AVE 2nd Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is restroom remodel on the 2nd floor. Total lighting area = 268 sq. ft.Note: Building permit has been pulled under 16016-10000-28413	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35581	10041-10000-14715	1444 S BUTLER AVE Bldg10	90025	11	129B149   200	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.04735	-118.45333	NEW SERVICE , PANELBOARDS AND CIRCUITS FOR 21 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35582	14041-10000-35678	1665 E MARTIN LUTHER KING, JR BLVD	90011	9	115-5A213 205	5117010015	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.01017	-118.24449	PV1 3.8kw standard plan with (11) modules and (1) inverter. plan check over counter per customer request.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35583	19041-10000-11049	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT TO TERMINAL-(6) AT  LEVEL 2 (MOTE AREA) - TOTAL AFFECTED AREA = 388 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35584	14041-10000-16174	333 S GRAND AVE	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 6 TH FLOOR.  (2300 sqft) , EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35585	12041-20001-30541	13455 W MAXELLA AVE 140	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	03/14/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	Delta 2 modifications on previously approved wet of plans.  Plan check for power and energy. First time tenant. Le Pain Quotidien. Unit #140. 3217 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35586	15041-20000-19302	13708 W HUBBARD ST	91342	7	222B157   209	2513005025	RS-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.30638	-118.43123	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35587	17041-10001-35356	9668 N QUARTZ AVE	91311	12	201B117   501	2761021023	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.24557	-118.56421	PC FOR CHANGES TO APPROVED SET. ALL CHAGNES ARE LOUDED ON THE PLAN. SCOPE INCLUDES RELOCATION OF INVERTER AND AC DISCONNECT. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER. PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(12)MODULES-CANADIAN SOLAR CS6K-275M(12)OPTIMIZERS-P320(1)INVERTER-SOLAREDGE SE3000H-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35588	13041-20001-33190	8020 W MELROSE AVE	90048	5	141B177   617	5527015005	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	PIN	34.08350631	-118.36447698	Changes to approved set.  2008 energy code is being used.  Relocation of lighting and recepticles.  All changes clouded with delta 1.  T24 FOR EXISTING SPACE. USE OF BUILDING HAS NOT CHANGED. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. 3500 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35589	12041-20002-19647	8301 W BEVERLY BLVD	90048	5	138B173   395	5514009027	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.07623	-118.37013	(((((DELTA 3 MODIFICATIONS TO APPROVED SET OF PLANS. CHANGES TO T24 ONLY))))))Delta 2 modification to previously approved set of plans to account for conduits penetrating into the methane zone under the building.  All conduits penetrating the methane zone shall be sealed at both ends, and the seals shall be specifically approved for 40% fill.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35590	16041-10000-37807	1589 S CARDIFF AVE	90035	5	129B169  1560	4306017044	R1-1	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.05029	-118.39224	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.80KWac. USING STANDARD PLAN.(10)MODULES-SOLARWORLD SW345(10)OPTIMIZERS- SOLAREDGE P400(1)INVERTER-SOLAREDGE SE3800-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35591	13041-10000-10834	18053 W ERWIN ST	91335	12	177B125   149	2123022005	(T)R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	PIN	34.1843787	-118.52667571	PV1 SINGLE FAMILY DWELLING PHOTOVOLTAIC SYSTEM TOTAL SIZE 7KW. USING 33 MODULES. CENTRAL INVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35592	13041-10000-11873	512 N CASCADA WAY	90049	5	141B145   350	4369015006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.08031	-118.46142	PV1 MICRO INVERTER SINGLE STORY HOUSE. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE:EH53-250} 20 modules]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35593	17041-10000-23810	950 S BROADWAY	90015	14	126A209    41	5139002022	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			Reviewed by Supervisor	08/10/2017 12:00:00 AM	ADDRESS	34.04113	-118.25698	NEW FIRE ALARM SYSTEM TO A HIGH RISE 7 STORY APARTMENT . 295 DEVICES AND A FIRE ALARM PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35594	13041-10000-20195	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	TENANT IMPROVEMNTS TO TERMINAL 3 TO ACCOMMODATE THE RELOCATION OF US AIRWAYS INTO TERMINAL 3 SPACES. TITLE 24 PLAN CHECK ONLY.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. LOCATION A , B, C & E.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35595	15041-20000-37147	7335 N SATSUMA AVE	91352	2	186B173   889	2410016012	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.20395	-118.3672	PV1, roof mounted solar panel, 9.405 kW DC(33) modules: SW 285 Mono(33) microinverters: Enphase M250Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35596	15041-20002-19693	16425 W TULSA ST	91344	12	210B137   852	2680022017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.26844	-118.49001	0$ PERMIT FEES DUE TO SENATE BILL 1222.[[[[ 7/6/15 CHANGES TO APPROVED SET. CHANGES TO ROOF LAYOUT ONLY. ]]]]Plan check for a PV1 roof-mounted PV system. System size is 4.3 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35597	14041-20001-00744	5333 N VENTURA CANYON AVE	91401	4	171B157   217	2344028017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/19/2014 12:00:00 AM	ADDRESS	34.16754	-118.42925	((((EXPEDITE FEES)))New rooftop PV system with DC/DC converters.  System is UNGROUNDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35598	17041-10000-08793	1900 S AVENUE OF THE STARS STE 625	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.05979	-118.41671	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR SUITE 625. TOTAL AFFECTED AREA IS 1660 SQ. FT. B#17016-70000-02453	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35599	15041-10000-05579	1121 S BOYLE AVE	90023	14	123A221   272	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.03075	-118.22046	T24 ONLY.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 5445 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35600	19041-10000-19741	7347 N ETHEL AVE	91605	2	186B161   532	2327001036	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.2045	-118.41828	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35601	14041-20000-07390	5 N OAKMONT DR	90049	11	135B137   302	4426019006	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.06668	-118.4906	NEW SINGLE FAMILY DWELLING 1000A SERVICE, PC FOR POWER ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35602	16041-20001-09616	16739 W LUDLOW ST	91344	12	210B137   511	2683003016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM			PC Approved	04/01/2016 12:00:00 AM	ADDRESS	34.27121	-118.49691	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (19) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35603	10041-20000-12945	4342-4350 N TUJUNGA AVE	91602	2	165B173   466	2366005005	[Q]C2-1XL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM	07/07/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	PIN	34.14918638	-118.37865849	Replacing existing main  800 amp service with new one.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35604	15041-10000-08766	360 E 2ND ST	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM			Reviewed by Supervisor	04/01/2015 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC FOR POWER. PROVIDE POWER TO NEW REPLACEMENT ROOFTOP BOILERS, COOLING TOWERS WITH VFD'S' CONDENSOR WATER PUMPS, AIR CONDITIONING UNITS, SUPPLY FANS, EXHAUST FANS AND AN EMERGENCY EYE WASH WATER HEATER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35605	16041-20000-17031	1108 S LOS ANGELES ST unit 101	90015	14	126A209   262	5145021022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.03808	-118.25716	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAKL SQUARE FOOTAGE 1960.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35606	16041-20000-41001	929 W JEFFERSON BLVD SUITE 1665	90007	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	Plan check for power and energy. Project site is an existing commercial building. Project scope is first time tenant/tenant improvement. Total lighting area = 28,204 sq. ft.Note: Building application has been generated under 16016-10000-27480	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35607	14041-10000-05558	523 W 6TH ST SUITE 534	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	Renovation to office tenant space in existing commercial highrise office building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35608	15041-20000-44010	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.2215	-118.42999	Plan check Power and Energy for Kaiser Permanente Department of Blood Draw. Total area: 3,652 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35609	12041-10001-14436	15431 W KESWICK ST	91406	6	189B145   666	2222009005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Expired	09/11/2014 12:00:00 AM	ADDRESS	34.21043	-118.4695	PLAN CHECK FOR NEW ROOF MOUNTED 4.16KW PHOTOVOLTAIC SOLAR SYSTEM USING SOLAREDGE TRANSFORMERLESS INVERTER AND DC-DC POWER BOX. EXISTING PERMIT #12041-20000-14436 FOR SOLAR-MODULES AND INVERTER.  Misc. Permit under this applicaiton is for the DC/DC Converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35610	10041-10000-11568	8310 W 3RD ST	90048	5	138B173   896	5511031037	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.07257	-118.37044	RENOVATION OF EXISTING TAKE-OUT RESTAURANT WITH INTERIOR NON BEARING PARTITIONS, COUNTERS, AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35611	11041-20000-00567	1901 S AVENUE OF THE STARS 15th Floor	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.05949	-118.41705	T.I. for a existing high rise building of 15th floor.  Install general/emergency lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35612	19041-20000-14840	9172 N ETON AVE	91311	12	198B105   136	2746010007	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.23772	-118.59399	Office/warehouse TI for (E) commercial space.  Plan check for energy - 18,100 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35613	18041-10000-47410	234 S RIMPAU BLVD	90004	4	135B185    40	5515008035	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Issued	01/04/2019 12:00:00 AM	ADDRESS	34.06983	-118.3302	$0.00 fee due to senate bill 12222 PC FOR NEW 18.9 KWDC AND 15.2 KWAC ROOFTOP PV SYSTEM AND 54KW ENERGY STORAGE SYSTEM, SCOPE INCLUDES (2) TESLA POWER WALL BATTERIES, (60) PV MODULES, AND (2) CENTRAL INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35614	10041-30000-00531	10765 W WILKINS AVE	90024	5	132B153   681	4325014013	[Q]RD1.5-1	West Los Angeles	Westwood			2656.00	Electrical	Electrical	Public Safety Only			01/12/2010 12:00:00 AM	01/12/2010 12:00:00 AM		Permit Finaled	11/10/2010 12:00:00 AM	ADDRESS	34.05657	-118.43799	New Fire Alarm Control Panel.  P/C is for Power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35615	17041-20001-03511	5015 N VELOZ AVE	91356	3	171B121   542	2176013027	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM			PC Approved	02/08/2017 12:00:00 AM	ADDRESS	34.16147	-118.54071	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD. Interconnect with a 200 MSP.Derating main breaker to 175A. 11.4kW ungrounded pv system. (44) 340W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35616	19041-10000-35069	5855 N WHITE OAK AVE	91316	5	177B129   882	2159027005	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.17741	-118.51886	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SE 7600H-US) WITH 22 MODULES USING P320 OPTIMIZERS AND ESS(TESLA POWER WALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35617	19041-10000-26218	7083 W HOLLYWOOD BLVD 1ST FLOOR	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.10173	-118.34439	TENANT IMPROVEMENT IN AN EXISTING COMMERCIAL OFFICE ON THE 1ST FLOOR OF A LOW RISE BUILING. INSTALLING LIGHTS. T-24 ENERGY ONLY. AREA OF WORK: 6,073 SQR FT. BUILDING PERMIT: 19016-10000-20648	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35618	13041-10000-12031	380 WORLD WAY SPACE T-49	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	12/21/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	First-time tenant in retail space at Tom Bradley Int'l Terminal at LAX (Vino Volo store).  Power and energy.  2 new panels and associated wiring coming off distribution board 4CN2BC.  1600 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35619	18041-10000-22252	3501 E VALLEY BLVD	90031	1	136-5A227  63	5211021901	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.06562	-118.20179	INSTALLING A NEW FIRE ALARM SYSTEM IN THE BUILDING WITH 29 DEVICES AND ONE FA CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35620	17041-10000-19107	11805 W TERRA BELLA ST	91342	7	213B169   672	2531017015	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.27861	-118.39072	PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 4.0KWAC14 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35621	16041-10001-07831	15365 W MAGNOLIA BLVD	91403	4	172-5A145  94	2250002023	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.16501	-118.46841	"08/11/16Changes to an approved set of plans. All changes are made under delta 1. Changes include adding/replacing lighting fixtures, and relocating branch circuits for exterior lights from panel ""1LA"" to panel ""1A"".Note: Permit is pulled under PCIS#16041-10000-07831(((((T-24, REPLACING AND ADDING NEW OUTDOOR LIGHTING TO A SCHOOL. TOTAL SQ. FT. 11427."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35622	14041-10002-10981	6007 S ST ANDREWS PL	90047	8	105B193   569	6001018009	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	33.98484	-118.3116	TI. for a commercial building 2-story. all changes apply to delta-2 only (((plan check for power. CORE/SHELL FOR (E) 2 STORY BLDG. THIS PERMIT COVERS THE COSTS OF BOTH 14041-10000-10981 AND 14041-10001-10981.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35623	13041-10001-30861	19913 W MARTHA ST	91367	3	174B113   291	2153017019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/27/2013 12:00:00 AM	ADDRESS	34.17348	-118.56639	Expedited RSES plan check per applicant request.PV1, Install 4.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 17 modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35624	15041-10000-14329	1110 S WESTERN AVE # 206	90006	10	129B193   694	5080010002	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.05041	-118.30886	ALTERATIONS IN BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35625	15041-20000-37428	100 WORLD WAY SPACE 136-F&B	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLANCHECK FOR T24 ENERGY FOR SMALL AREA WITH REFRIGERATED CASES. 179 SQFT. SPACE 136 F&B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35626	14041-10000-12869	9191 N MERCEDES AVE	91331	6	198B157   822	2625014001	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.23664	-118.42517	PV1 ROOF MOUNTED TRANSFORMERLES SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 4.2KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35627	16041-10000-32962	534 N BARNABY ROAD	90077	5	141B149   251	4362006002	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2016 12:00:00 AM			Reviewed by Supervisor	10/13/2016 12:00:00 AM	ADDRESS	34.07896	-118.45398	Plan check for house addition remodel with new 1,200A Service and 600A distribution board and re-feed existing 800 A distribution borad.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35628	12041-10000-23661	342 N SAN FERNANDO ROAD	90031	1	139-5A219   6	5447009017	MR2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	ADDRESS	34.07793	-118.22327	PLAN CHECK POWER AND ENERGY FOR INTERIOR TENANT IMPROVEMENT OF AN EXISTING MULTI PURPOSE HALL. MORE THAN 100 OCCUPANTS.  FIRE ALARM VARIANCE IS SUBMITTED TO SEPERATE THE ELECTRICLA PLAN FROM FIRE ALARM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35629	15041-10000-37762	5715-5717 N FIGUEROA ST	90042	1	151-5A229 170	5492001015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.10994	-118.19246	RENOVATION TO EXISTING BUILDING. NEW CORE AND SHELL WORK. NEW SERVICE AND HOUSE LOADS. NO TI AT THIS TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35630	14041-10000-12010	1639 W 81ST ST	90047	8	099B193  1079	6034007021	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Expired	05/31/2016 12:00:00 AM	ADDRESS	33.96559	-118.30603	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35631	13041-20000-05163	6060 W CENTER DR 4th flr	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	33.97602	-118.39073	Plan check for energy and emergency lighting. 4th floor of commercial high-rise. ALL3Media	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35632	17041-20000-25677	9301 N WINNETKA AVE	91311	12	198B113   122	2748038032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.23934	-118.57134	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 24,666 sq. ft.Note: Building application has been generated under 17016-20000-19290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35633	18041-10000-34880	888 S FIGUEROA ST #850	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.0465	-118.26225	new luminaires in new private officesplan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35634	14041-20001-04287	9550 N YOLANDA AVE	91324	12	201B121   707	2763003020	RA-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.24428	-118.54031	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING DC COMBINER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35635	10041-10001-13977	11307 W MISSISSIPPI AVE GLAM DOLL	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM			PC Approved	08/04/2010 12:00:00 AM	ADDRESS	34.03947	-118.44296	TI IN A RETAIL STORE. FIRST TIME TENANTS. PLAN CHECK IS FOR THE PANEL & CIRCUITS. EXISTING 1200 AMP SERVICE.   TITLE 24 ENERGY APPROVED AND PERMIT ISSUED UNDER 10041-10000-13977.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35636	13041-10001-30707	1810 S BROADWAY	90015	14	123A207    63	5126029009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.03232	-118.26486	"Removing two old panels with two new panel with the same size and rating(Panels RPA & RPB).5/5/2014{{FULL PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO (E) RETAIL FROM ""BROADWAY RETAIL STORE"" TO ""ASHLEY FURNITURE STORE"". CHANGE OF USE FOR 2 LEVELS. TOTAL INDOOR ILLUMINATED AREA IS APPROXIMATELY 48640 SQ FT. EXISTING 800A METER/MAIN 277/480V, 3-PHASE 4-WIRE. ADDITIONS OF 1 NEW 150A PANEL ""21B"", NEW CKTS. DESIGN BUILD C10 CONTRACTOR.}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35637	13041-10000-21146	12652 W VILLAGE LANE bldg #5	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35638	17041-10000-11650	1800 N HIGHLAND AVE	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.10436	-118.33763	PC FOR TI, TITLE 24 ENERGY ONLYIN A HIGH RISE BUILDIGN TOTAL AFFECTED AREA  OF 2877 SF INSTALLING NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35639	14041-20000-14970	3924 S DEGNAN BLVD PV1	90008	10	117B185  1133	5033015006	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.01391	-118.33028	PV1. Install 3 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with power optimizers (DC-DC converters)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35640	16041-10000-14005	12518 N HERRICK AVE	91342	7	219B153   236	2508025015	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.29787	-118.44334	PV1,NEW 3.7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(1) INVERTER: POWER ONE 3.6KW(15) MPS250P-20/U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35641	16041-10002-35209	718 E JACKSON ST	90012	14	130-5A217 325	5173015006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.0509	-118.23282	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGED NOTED DELTA 5. CHANGE TO MAIN FITNESS ROOM LIGHTING LAYOUT. UPDATED T24 PROVIDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35642	13041-10000-35701	1015 S CROCKER ST #R20	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 558 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35643	17041-10000-04261	10036 N ANDASOL AVE	91325	12	204B129   446	2734030035	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.25328	-118.51318	PC for a PV1 roof mounted installation in a single family home. New sysem consists of 40 MicroInverters rated at 327 Watts each. Total size of the system is 13.08KW. Also adding a 125A Load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35644	19041-20000-21329	8918 N LINDLEY AVE	91325	12	195B125   361	2768006002	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.23236	-118.52716	PV1.  Install 10.4 kW DC / 7.6 kW AC roof mounted grid tied PV system.  (32) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35645	18041-10001-32582	5858 W ABERNATHY DR	90045	11	099B169   101	4105006013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM			PC Approved	09/26/2018 12:00:00 AM	ADDRESS	33.97081	-118.38396	EXPEDITED PER APPLICANTS REQUEST.PV1. 11.7KW ROOFMOUNTED SOLAR SYSTEM + ENERGY STORAGE DEVICES 40.5KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35646	19041-10000-53744	15001 S FIGUEROA ST	90248	15	072B201    76	6120029009	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			Reviewed by Supervisor	01/08/2020 12:00:00 AM	ADDRESS	33.89604	-118.28344	Scope work includes a underground service rated for 3000A  277/480V that supplies power equipment. Electrical equipment include panel boards, transformers, and circuits. Total affective area: 13,250 sqft..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35647	19041-10000-45830	6142 W 75TH ST	90045	11	102B165   745	4106005020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Expired	03/01/2024 12:00:00 AM	ADDRESS	33.97305	-118.39345	NEW ROOF MOUNTED 4.8KW PV SYSTEM WITH 12 @ (400W) AC PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35648	17041-10000-30060	350 W 5TH ST 105	90731	15	015B201    39	7455014035	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	33.73981	-118.28471	PC FOR POWER AND ENERGY FOR MEDICAL OFFICES (CHANGE OF USE)SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 4508 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35649	14041-10001-10186	4346 W KINGSWELL AVE	90027	4	148-5A201  31	5591026003	R2-1XL	Central	Hollywood	Los Feliz		1952.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.1026	-118.28467	Expedited RSES plan check per applicant request. {{Install 4 kW DC roof-mounted solar array on a single-story house, interconnect with  main service panel. (1)Transformerless inverter: SOLAREDGE SE 3800A-US-ZB-U. (16) Modules: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35650	19041-30000-18563	6222 W WILSHIRE BLVD 4th Floor	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM			PC Info Complete	05/16/2019 12:00:00 AM	ADDRESS	34.06309	-118.36418	Plan check for Title 24 only. Project site is common area corridors and restrooms on the 4th floor. Project scope is a tenant improvement. Total lighting area = 1,255 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35651	13041-10002-35682	14738 W BLACKHAWK ST	91345	7	204B149   186	2648010007	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.25803	-118.45366	Modifications to approved set.  Removal of separate GEC from inverter to system ground.  (((PV1, Install 4.5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (18) modules Trina Solar TSM-250PA05.18.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35652	19041-20000-12814	15303 W VENTURA BLVD STE 1260	91403	4	168B145   682	2264001040	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM			PC Info Complete	04/09/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	Plan check for Title 24 energy only in existing space Tenant Improvement. Totala area: 3048 sq ft. B#19016-40000-07162	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35653	18041-10000-47740	181 W 42ND ST	90037	9	114A203   100	5111019023	RD2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.00745	-118.27588	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.49KWdc / 4.32KWac.(18)MODULES-HANWHA Q.PEAK.G4.1 305(18)MICROINVERTERS-ENPHASE IQ7-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35654	17041-20001-43129	7842 N MELBA AVE	91304	12	189B093   505	2020023007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.21298	-118.63443	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.22.8kW ungrounded system. (2) 11.4kW SolarEdge inverters.(87) 330W pv modules. (87) 400W power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35655	17041-10000-02880	13643 W MUSCATINE ST	91331	6	195B157  1199	2637007028	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.22682	-118.42955	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(1)INVERTER-SE3800A-US(12)MODULES-VBHN325SA16(12)OPTIIMIZERS-SOLAREDGE P400	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35656	11041-20000-12014	5230 N VAN NUYS BLVD	91401	2	172-5A151 205	2248013009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Closed	04/29/2014 12:00:00 AM	ADDRESS	34.16582	-118.44847	T.I. to existing building.  Install general/emergency lighting in office, outdoor door drop-off, and outdoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35657	16041-10000-22528	6661 N YARMOUTH AVE	91335	3	180B129   224	2122018006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.19206	-118.51982	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.14KWdc / 3.0KWac.(12)MODULES-SPR-X21 345(1)INVERTER-SB3000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35658	11041-20000-19175	14104 W FOOTHILL BLVD	91342	7	225B153   185	2504011155	C2-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.31556	-118.44118	7-Eleven t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35659	19041-10000-13330	216 S LAKE ST	90057	13	135A205    63	5154008019	R3-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.0657	-118.27208	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 48 AC MODULES (SPR-X22-360-D-AC). SYSTEM SIZE IS 17.28KWdc AND 15.95KWac. SCOPE INCLUDES NEW 125A SUBPANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35660	14041-20000-01096	7654 N BALASIANO AVE	91304	12	186B093   717	2014033044	(Q)RD5-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.20932	-118.63121	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35661	18041-10001-45255	13340 W SATICOY ST Unit H	91605	2	186B157   195	2303024031	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			PC Info Complete	05/29/2019 12:00:00 AM	ADDRESS	34.20828	-118.42362	"Changes to an approved set of plans. All changes are clouded under delta 3. Changes include revision on scope of  work to read: ""TI on (E) Warehouse units No. H"",  adding one 100A panel, new circuits for AC, revising lighting floor plans, revising load calculations.  B#18016-20000-37278"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35662	13041-20000-29945	6217 N MAMMOTH AVE	91401	2	177B153   325	2239007030	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.18355	-118.43247	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.46 KWAC. 16 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35663	17041-10000-15035	900 W WILSHIRE BLVD	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR POWER AND ENERGY FOR DC SYSTEM (6000 AMP BUS, 52V )UPPLYING POWER TO SIGNAGE. SIGN LIGHTING FORMS PROVIDED AND DC RISER PROVIDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35664	19041-20001-52173	1150 N DOHENY DR	90069	4	144B169   407	5560031016	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.09188	-118.39029	Expedited plan check fee.PV1.  Install 24 kW DC roof mounted grid tied PV system and 19.8 kWh energy storage system with associated distribution.  (80) modules with (4) 3.8 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35665	07041-10002-13283	3542-3544 E 3RD PL	90063	14	123A229    16	5179014030	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM			PC Approved	03/22/2010 12:00:00 AM	ADDRESS	34.03301	-118.19329	Plan check is for T-24 and emergency egress lighting.  Previously approved set of plans were lost. There is an existing permit. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35666	18041-20000-24226	5610 W PARK OAK PL	90068	4	153B193    64	5580029008	RE15-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.11682	-118.31162	Installation of 54 kWh energy storage system.  Associated replacement of service equipment/distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35667	15041-20000-13495	1001 S BROADWAY	90015	14	126A209    61	5139013022	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.04086	-118.25782	Title 24 plan check only.  Total area = 1,084 sq. ft.  T.I. to existing low rise commercial space.  Change of use from retail to restaraunt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35668	16041-20000-05916	5161 N DUMONT PL	91364	3	171B109   238	2166016008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.16302	-118.58002	Plan check for PV roof mounted system. System size: 10.3kW with 48 modules and 48 microinverters connected to load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35669	15041-10000-17578	1521-1523 W FLORENCE AVE	90047	8	102B193  1243	6015034020	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM			PC Info Complete	06/08/2015 12:00:00 AM	ADDRESS	33.97474	-118.30318	SERVICE UPGRADE 800 AMPS FOR COMMERCIAL BUILDING.  PLAN CHECK FOR POWER ONLY.  ALL PANELS AND LOADS TO BE FUTURE ON SEPERATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35670	15041-20000-17088	2917 E 1ST ST	90033	14	126A225    32	5180020036	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.04084	-118.20294	Plan check for power and Title-24.  Total area = 5,023 sq. ft.  T.I. to commercial office first time tenant.  New lighting and recepticles.  Fire alarm variance has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35671	13041-10000-13069	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.03396	-118.24117	"PC FOR ENERGY FOR ROOF DECK LIGHTING. REF to express permit 13016-10-08311CRA approved with conditions------------------------NO: 93939  -- Building/Electrical/MechanicalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 12/22/2010 by Inspector JOHN STEPHENS atphone# (213)252-3051.  CEIS Case Number is 401856.Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.(Created: IMSV7 / 12-20-10)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~""COMPLY WITH DEPARTMENT ORDER effective date 12/22/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35672	15041-10001-32209	5514 W CARLIN ST APT #1	90016	10	123B177  1332	5048027004	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM			Reviewed by Supervisor	10/15/2015 12:00:00 AM	ADDRESS	34.03098	-118.36376	EXPEDITE PER APPLICANT. (((PV2. NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING 2-STORY BUILDING. TOTAL SYSTEM SIZE 2.65KW. SYSTEM TO BE INTERCONNECTED WITH MAIN PANEL. (1) INVERTER-ABB#PVI-3.0-OUTD-S-US-Z-A(10) KYOCERA #KU2656ZPA))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35673	12041-10000-09245	515 S FIGUEROA ST # 1235	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	remodeling of officesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35674	10041-20000-22836	7651 N LAUREL CANYON BLVD	91605	6	186B165    52	2307013001	(T)(Q)R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	Apartment			11/15/2010 12:00:00 AM	10/04/2011 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.20996	-118.39692	PLAN CHECK FOR NEW 34-UNIT APARTMENT BUILDING.  MODIFICATION FOR SEPERATE FIRE ALARM SYSTEM FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35675	14041-10001-14470	2670 N GRIFFIN AVE	90031	1	139-5A223  15	5206010039	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM			PC Approved	07/21/2014 12:00:00 AM	ADDRESS	34.07841	-118.21167	((EXPEDITE FEES))PV2 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 75KWAC. 275 MODULES AND 5 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35676	16041-10000-17314	21325 W CANDICE PL	91311	12	210B105    21	2706034009	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.27301	-118.59544	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(21)MODULES-HYUNDAI HiS-S280RG(1)INVERTER-FRONIUS PRIMO 5.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35677	17041-10000-27782	10250 W SANTA MONICA BLVD # 2700	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan check for first time tenant space-ALOHA  Poke suite 2700	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35678	19041-20000-28733	6433 E CRESCENT ST	90042	14	154-5A233 230	5493018021	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.11693	-118.1788	Plan check for PV roof mounted system, system size: 8.91KW DC, 8.084KW AC with 27 PV Modules and 27 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35679	13041-20000-32997	1546 E 22ND ST	90011	9	118-5A213 218	5118005009	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.01806	-118.24686	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC. 14 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35680	14041-20001-08979	14318 W AZTEC ST	91342	7	219B153   344	2507027009	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.2959	-118.44494	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35681	10041-20000-25413	5205 S OCEAN FRONT WALK	90292	11	100-5A149 231	4294007***	R3-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Approved	12/22/2010 12:00:00 AM	ADDRESS	33.96758	-118.45757	energy plan check lobby and stairways	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35682	15041-10000-34042	1800 S AVENUE OF THE STARS PK Level-Restroom	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Issued	10/27/2015 12:00:00 AM	ADDRESS	34.06095	-118.41786	Title 24 plan check only.  Total area = 355 sq. ft.    T.I. to restroom in existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35683	07041-10002-29090	18825 W SATICOY ST	91335	3	186B121    91	2103016040	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM			PC Approved	05/13/2010 12:00:00 AM	ADDRESS	34.20853	-118.54321	REVISIONS TO PERMITTED SET OF PLANS- ADDED EXTERIOR LIGHTING FOR NON-SALES CANOPY AND WALKWAY  AND REVISED THE LIGHTING  FIXTURES NEAR THE ALTAR/CLERESTORY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35684	13041-20000-35731	10429 N WHEATLAND AVE	91040	7	204B177    38	2542006002	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Expired	01/26/2016 12:00:00 AM	ADDRESS	34.2591	-118.358	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.25KW. 17 MODULES AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35685	16041-10000-04298	6751 W HOLLYWOOD BLVD 1ST FLR-MEZZ	90028	13	148-5A185  98	5547011015	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.10172	-118.33753	T-24, INTERIOR TI TO [E] RETAIL SPACE IN A HIGH RISE BUILDING. SCOPE OF WORK IS IN THE GROUND FLOOR LEVEL. NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 5365.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35686	08041-10003-18294	10366 W WILSHIRE BLVD 1-9	90024	5	135B157   139	4327013***	[Q]R5-3	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			12/13/2011 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	ADDRESS	34.06722	-118.42766	new panel boards and circuits and UGPS for existing apartment buildiong	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35687	10041-20000-09876	5850 N CANOGA AVE #120	91367	3	174B105     9	2149002016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	08/20/2010 12:00:00 AM	ADDRESS	34.17678	-118.59723	INTERIOR OFFICE TENANT IMPROVEMENT AT FIRST FLOOR OF EXISTING OFFICE BLDG ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35688	18041-20000-36875	18546 W ROSCOE BLVD ste 308--310	91324	12	192B125   923	2103005052	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM			PC Approved	09/26/2018 12:00:00 AM	ADDRESS	34.22047	-118.53793	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35689	19041-10000-16528	2645 S WESTERN AVE	90018	10	123B193   873	5053001026	C2-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.01	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM			PC Info Complete	07/16/2021 12:00:00 AM	ADDRESS	34.03134	-118.30922	Full plan check for a new 3-story Hotel with 1 level of abv grade parking and 1 levels of subterranean parking garage. scope includes new 16000A service. total affected area is 49874 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35690	18041-10000-35180	19536-19544 W CARDIN PL	91324	12	198B117   258	2761035101	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			09/14/2018 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.23752	-118.55933	PLAN CHECK FOR POWER ONLY. NEW 5 UNIT TOWNHOUSE BUILDING WITH ATTACHED GARAGESnew 600A 120/240V 1P/3W Servicebuilding permit # 18010-30000-01137	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35691	17041-20002-00382	15760 W STRATHERN ST	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM			PC Approved	05/22/2017 12:00:00 AM	ADDRESS	34.21559	-118.47701	Revisions to approved plans.  Changes made to load shedding scheme details to comply with emergency egress lighting requirements.  (((Plan check for power only. Project site is an existing commercial building. Project scope is the installation of an optional standby generator system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35692	15041-20001-39373	10250 N DEERFIELD LANE	91324	12	204B117   212	2729027054	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	34.25693	-118.55235	EXPEDITE PER APPLICANT REQUESTInstall a roof mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 15.4kW (2 - 7.7kW inverters). Ungrounded system. (52) 327W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35693	15041-20001-16517	16515 W BALLINGER ST	91343	12	201B137   947	2677005004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.24394	-118.49185	Changes to an approved set of plans. Changes are only to the PV module layout.*****Previous Work Description*****pv1 sfd. total system size 3.2kw ac using microinverter system. using enphase m215. nonstandard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35694	18041-10000-06396	10201 W PICO BLVD BLDG 12	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Public Safety Only			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	VOLUNTARY NEW FIRE WARNING SYSTEM WITH 24HR SUPERVISORY MONITORING STATION IN COMMERCIAL BUILDING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35695	18041-20000-16365	11254 W MISSISSIPPI AVE # 1-4	90025	11	126B153   833	4260001002	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.03992	-118.44161	Fire alarm system for 3-story 4-unit apartment building.    (31) devices, FACP, and annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35696	17041-20001-36729	20313 W VALERIO ST	91306	3	186B113   570	2114010008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM			PC Approved	10/25/2017 12:00:00 AM	ADDRESS	34.20478	-118.57583	expeditepv1install roof mounted pv system sized 13.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35697	15041-20000-33446	16030 W VENTURA BLVD Suite 260	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.15598	-118.48247	Plan check for energy only. TI to office on 2nd floor of high rise building. New lighting (incl. emergency) and receptacles. 6,801sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35698	18041-10000-27961	12001 W SAN VICENTE BLVD	90049	11	129B141   153	4404023019	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.05229	-118.47338	Energy plan check for an office T.I. Scope includes new light and equipment for a teller line located in an existing bank with a (305) SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35699	12041-10000-19694	17060 W WESTBURY DR	91344	12	219B133   256	2608023022	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.29856	-118.50475	New 6.5kw rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35700	13041-10001-34450	6216 N MAMMOTH AVE	91401	2	177B157   341	2239007067	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.18355	-118.43217	Expedited RSES plan check per applicant request.{{PV1, Install a 4.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (18) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35701	19041-20000-50587	7150 N HELMSDALE CIR	91307	12	183B093    93	2028024004	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.20049	-118.64279	PV1. INSTALL 9.3 KW DC PV SYSTEM WITH (30) MODULES-OPTIMIZERS, (1) INVERTER(SE7600) AND (1) LG STORAGE SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35702	12041-20000-18292	10901 W VENTURA BLVD	91604	2	162B173   525	2366022022	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM			PC Approved	08/06/2012 12:00:00 AM	ADDRESS	34.14011	-118.368	T.I. to existing building for a bank.  Install indoor general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35703	18041-10000-27601	5315 W 102ND ST	90045	11	090B173   164	4129030015	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.94375	-118.373	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35704	16041-10000-34126	2049 S CENTURY PARK EAST 2550	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK FOR T-24 ONLY.  TENANT IMPROVEMENT TO (E) TENANT SPACE ON 25TH FLOOR. INSTALL NEW LIGHTS, RECEPTACLE, 45KVA, 225 A PANELS WITH ITS CIRCUITS. NEW LOAD < 400A, TOTAL AFFECTED AREA  4,075 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35705	11041-10000-19648	8300 N TAMPA AVE	91324	12	192B117   733	2784019004	C2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM	09/15/2011 12:00:00 AM		Permit Closed	06/13/2013 12:00:00 AM	ADDRESS	34.2208	-118.55334	T-24 and emergecncy lighting plan check only for CHG OF USE FROM RETAIL TO BAR/POOL HALL/NIGHT CLUB. 4062 S.F.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35706	17041-20000-11857	21622 W PLUMMER ST Suite 100	91311	12	198B105    40	2746014042	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.24254	-118.60152	Plan check for Title 24 only. Project site is the 1st floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,708 sq. ft.Note: Building permit has been issued under 17016-10000-07119	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35707	11041-20000-10419	5126-5130 N LANKERSHIM BLVD	91601	4	171B173   797	2353007015	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Expired	06/12/2013 12:00:00 AM	PIN	34.16376566	-118.37360108	upgrade service 200 A to 600 A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35708	18041-10000-13867												Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Approved	04/18/2018 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35709	18041-20000-43997	11862 N KILLIMORE AVE	91326	12	213B121    31	2872013001	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.28443	-118.53933	pv1install roof mounted pv system sized 10.6KW AC interconnected with msp.rated AC-CEC 9.621KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35710	18041-10000-32787	8550 N BALBOA BLVD STE 234	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.22649	-118.5024	REPLACE INDOOR FLOURESENT TROFFERS WITH NEW LED RETROFIT KITS & REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35711	19041-20001-22442	1437 N KINGS ROAD	90069	4	147B173   542	5555013028	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	34.09628	-118.37285	Expedite per applicant request Plan check for PV roof mounted system, PV system size: 14.62KW DC, 12.43KW AC with 45 PV Modules and 45 microinverters connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35712	17041-10002-08297	9171 N GAZETTE AVE	91311	12	198B109   142	2748036024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.23761	-118.58729	Changes to approved set of plan - Changes include main panel fault current change from 22KAIC to 10KAIC(Field clarification). and removal of combiner box only.  Inspector to verify # of inputs per tracker. Original permit #17041-10000-08297Plan check for a PV2 roof-mounted PV system. System size is 36 kWac and consists of (3) inverters, (126) modules, and (1) solar load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35713	15041-10000-28995	13652 W CANTARA ST 2nd Flr	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.21973	-118.43084	Plan check for power only; Scope includes (1) new circuit for exam rooms located in the medical building (Kaiser Permanente).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35714	14041-10001-13483	8570 W COLE CREST DR	90046	4	150A173   757	5556014049	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.10346	-118.37773	Install roof mounted solar array. For residentail with 600amp service connected to battery back up systemSystem size = 8 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35715	13041-10000-28968	1037 N HELIOTROPE DR	90029	13	144B197   792	5538019002	[Q]C2-2D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.0905	-118.29515	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 2880 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35716	14041-20000-22623	19801 W NORDHOFF PL Unit 111	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Issued	08/22/2014 12:00:00 AM	ADDRESS	34.23568	-118.56464	Plan check for commercial warehouse/office tenant space.  Connected load under 400A, plan check for Title 24 under 2008 standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35717	15041-20000-14403	19630 W ROMAR ST	91324	12	204B117   396	2726010011	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.25446	-118.56142	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (21) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35718	11041-20000-19757	9656 N WHITE OAK AVE	91325	12	201B129   269	2755007014	RA-1	North Valley	Northridge	Northridge East		1151.01, 1151.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	10/13/2011 12:00:00 AM	ADDRESS	34.24651	-118.51986	9.87 kw solar system roof mounted single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35719	18041-10000-46804	9777 N TOPANGA CANYON BLVD	91311	12	201B101   201	2727012064	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.24852	-118.60657	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35720	18041-10000-00126	7735 N WINNETKA AVE	91306	3	189B113  1111	2107022078	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.21153	-118.57129	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 44 MODULES (REC SOLAR REC285TP2, 285W), OPTIMIZERS (SOLAR EDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE11400A-US). SYSTEM SIZE IS 11.4KWac AND 12.32KWdc.Zero PV fees due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35721	16041-10000-01554	15229 W DE PAUW ST	90272	11	126B125   940	4412028031	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.03725	-118.52489	INSTALL 10.230 KW DC ROOF-MOUNTD SOLAR ARRAY ON A SINGLE FAMILY 2-STORY HOUSE.(33) MODULES: LG ELECTRONICS LG310N1C-G4(1) INVERTER: SOLAREDGE SE 10000A-US 240	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35722	13041-10000-31872	1143 S MAPLE AVE	90015	14	124-5A209  87	5145022033	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.03621	-118.25611	PLANCHECK AND PERMIT FOR T24 ENERGY ONLY . REMOVE HID LIGHT FIXTURES AND REPLACE IWTH NEW FLUORESCENT FIXTURES. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 720 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35723	19041-10000-15392	1001 S CROCKER ST #8	90021	14	124-5A211 211	5132011044	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.03489	-118.25066	remove HID fixtures and replace with new LED fixtures (indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35724	16041-20000-23942	23334 W HARTLAND ST	91307	12	183B093   662	2028017006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Expired	08/15/2018 12:00:00 AM	ADDRESS	34.19436	-118.63581	PV1.  Install 10.0 kW AC PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35725	13041-10000-29230	21820 W BURBANK BLVD BLDG A	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.17228	-118.6032	"PV-2.  "" $0 permit fee is due to the 2012 Senate Bill No. 1222"" Plan check power for 135KW DC roof mounted photovoltaic system for Warner Gateway Building A. Building permit and clearances under #13016-10000-21826"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35726	16041-10000-31943	11712 W SAN VICENTE BLVD	90049	11	129B145    62	4265006025	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.05333	-118.46601	PC FOR T24 ENERGY ONLY. NEW LIGHTING FOR PIZZAERIA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35727	16041-10000-38694	3023 E FUTURE PL	90065	1	148-5A217 268	5455012023	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.10112	-118.23114	PV1 roof mounted solar system installation. Installing a 6.0 kWac inverter along with 21 solar panels.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35728	17041-10000-20208	14040 W FOOTHILL BLVD	91342	7	225B153   250	2504019049	R3-1-CPIO	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	09/13/2020 12:00:00 AM	ADDRESS	34.31435	-118.43968	PC FOR PV SYSTEM CONNTECTED TO EXISTING MAIN PANEL. THIS IS COMMERCIAL PV. THIS SYSTEM USES 5 INVERTER, TOTAL RATED 55.6KW AC. THIS SYSTEM NET METERS METER # M19-13751. THIS IS SYSTEM 2/3 ON SAME ROOF. SYSTEM USES POWER OPTIMIZERS. NOTE: Permit fees due are $0 due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35729	14041-20000-13368	740 S OLIVE ST #105	90014	14	127-5A209  18	5144013034	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.04537	-118.25644	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO A DENTAL OFFICE. SUITE 105	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35730	12041-10000-04989	10515-10525 W WASHINGTON BLVD	90232	5	117B165   253	4208008039	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Expired	03/31/2014 12:00:00 AM	ADDRESS	34.01796	-118.40403	Upgrade of an fire alarm panel, all devices are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35731	12041-10000-01921	10643 W SUNSET BLVD Bldg #1	90077	5	138B153   103	4362009012	A1-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00, 2653.01	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.07571	-118.44485	Plan check for new 2000A service and distribution boards. Existing charter school buildings. Consolidating multiple services into one service. No new loads added.  (1 of 3 - This Permit 12041-10000-01921 is for building #1, Permit #12041-10001-01921 is for Building #2 and Permit #12041-10002-01921 is for Building #3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35732	11041-10000-08149	1048 N NAPOLI DR	90272	11	129B133   331	4408008007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2011 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.04672	-118.50527	New SFD. New 800 Amp service, board, and circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35733	14041-10000-00795	707 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	33.78001	-118.24199	Plan check for fire alarm system per inspector request.  Original permit issued under 13041-10000-32264.  Additional permit items (FACP and FATC serving modular and maintenance buildings).  (((INSTALL NEW FIRE ALARM DEVICES IN BERTH 200 RAIL YARD MAINTENANCE & MODULAR BUILDINGS T.I. TO MEET PROPER AREA COVERAGE PER NFPA 72.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35734	15041-10000-16727	434 E 80TH ST	90003	9	099B205   912	6030032021	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	33.96637	-118.2661	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.  (6) KYOCERA 260 MODULES(1) ABB PV1 3.0 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35735	19041-10000-16163	7734 N CRANER AVE	91352	2	189B173   798	2409011028	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.21118	-118.36907	Plan check for a PV1 5.3KW AC / 6.27KW DC roof mounted system with (22) modules, (22) mircroinverter, and (1) combiner box interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35736	12041-10000-03681	953 N COLE AVE	90038	4	144B185   981	5533021002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Public Safety Only			02/17/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Expired	11/20/2015 12:00:00 AM	ADDRESS	34.08858	-118.33005	Plan check original approved under #09041-10000-00641. Install a fire alarm system for an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35737	18041-20000-13827	1422 N DEVLIN DR	90069	4	144B169    44	5560001023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	ADDRESS	34.09493	-118.3872	PC for power for new SFD with 600A service.  Installing new service, panelboards, lights, receptacles and equipment. Electrical permit issued under combination permit 15010-10000-00932.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35738	15041-20001-10020	12465 W OSPREY LANE unit 1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	33.97923	-118.41018	Expedite per applicant request(((((Plan check for PV roof mounted system for tri-plex unit #1 with system size: 1.84kW. PV clearance shall apply to Unit #2 and # 3 for address 12456 osprey Lane, Los Angeles CA 90094))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35739	10041-10002-23433	11811 W KIOWA AVE 1-9	90049		129B145   548	4265015035	R3-1		Brentwood - Pacific Palisades				Electrical	Electrical	Apartment			09/20/2011 12:00:00 AM			PC Info Complete	09/20/2011 12:00:00 AM	ADDRESS	34.04961	-118.46467	NEW 9-UNITS APARTMENT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35740	18041-10000-14640	227 S WOODBURN DR	90049	11	135B145   328	4365004013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.0679	-118.46703	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 29 MODULES (LG 355Q1C-A5), OPTIMIZERS (SOLAR EDGE P400) AND A CENTRAL INVERTER (SOLAREDGE SE7.6A-US). SYSTEM SIZE IS 7.6KWac AND 10.295KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35741	12041-10000-14812	3350 S CLUB DR	90064	5	123B165   941	4316031008	R1-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	08/01/2012 12:00:00 AM	ADDRESS	34.03136	-118.40292	PV system for a single family dwelling. 5.52kW DC. Enphase micro inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35742	16041-10000-04730	660 S FIGUEROA ST 14TH FLR	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.04953	-118.25947	T.I FOR A COMMERCIAL OFFICE  ON THE 14TH FLOOR. TOTAL AREA 4393 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35743	19041-20001-24210	13236 W CANTARA ST pv1	91605	2	192B157  1030	2304008052	(T)RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.21969	-118.42129	expeditepv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35744	19041-20000-10977	9514 N RESEDA BLVD #11	91324	12	198B125    31	2764008020	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.24339	-118.53587	T24 PLAN CHECK FOR ENERGY ONLY FOR EXISTING RESTAURANT. TOTAL SQUARE FOOTAGE = 744SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35745	19041-20000-13400	7230 S DUNFIELD AVE	90045	11	102B165   340	4110006009	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	33.97585	-118.39786	Plan check for a PV1 roof-mounted PV system. System size is 5.04 kWdc/7.6 kWac and consists of (1) inverter, (14) modules, (1) transformer, (1) load center, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35746	14041-10000-22768	123 W 9TH ST	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	PIN	34.04230399	-118.25556747	Title 24 plan check only.  Total area = 1,847 sq. ft.  TI to existing retail space.  Removal of one wall and installation of new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35747	13041-20000-21457	6253 W HOLLYWOOD BLVD 1-53	90028	13	148-5A189 343	5546030035	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.10179	-118.32624	RENOVATION OF EXISTING OFFICES. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 329 SQ FT. PERMIT WILL BE ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35748	14041-20000-06001	5333 N ROYER AVE	91367	3	171B097   200	2042010042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.16762	-118.62785	pv1 single family dwellding. ttoal system size 6kw ac using transformerless inverter nonstandard plan. using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35749	19041-10000-47406	11951 W PINNACLE PL	90210	2	156B165   100	2382020053	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.12513	-118.39743	***$0 Permit fee due to AB1414***NEW ROOF TOP SOLAR SYSTEM PV1 CONSIST OF 78 MODULES (LG320) WITH 78 MICROINVERTERS (IQ7PLUS). SCOPE INCLUDES NEW 200A PV SUBPANEL CONNECTED TO (E) 800A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35750	19041-10000-31986	110 E 9TH ST 9TH FLR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Energy plan check for a partial office T.I located on the 9th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 25,852-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35751	12041-10000-13003	1925 S CENTURY PARK EAST 1ST FLOOR	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Issued	10/11/2012 12:00:00 AM	ADDRESS	34.06066	-118.41426	EXISTING CHASE BANK INTERIOR RENOVATION.  SCOPE OF WORK INCLUDING:  DEMOLISHING EXISTING NON-BEARING PARTITIONS, TELLER LINE & FINISHES.  CONSTRUCT NEW NON-BEARING PARTITIONS/CEILINGS WITH STRUCTURAL FRAMING &...(see additional comments)FULL PLAN CHK REQUESTED BY APPLICANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35752	17041-10000-33804	8210 N HASKELL AVE	91406	6	192B141   505	2673022046	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.21968	-118.47475	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35753	14041-20000-26366	4250 N COSTELLO AVE PV 1	91423	4	165B153   602	2266016009	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.14821	-118.43711	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.  6.98KW SYSTEM, 3.0 KW AND 4.0 KW INVERTERS.this application is for plan check for pv system. permit already issued. pc for 7kw 2 central transformerless inverters. meter socket and AC disconnect. this application is plan check only. no permit to be issued. permit finalled under application number 14041-20000-15606	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35754	13041-10000-35879	947 S TIVERTON AVE 14F	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			12/24/2013 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.06246	-118.44303	pc for power and energy. assisted-living TI EXIST APT UNITS ON ENITRE 14TH FLOORS.4TH AND 5TH FLOOR PC # 13041-10000-356426TH AND 7TH FLOOR PC # 13041-10000-358628TH AND 9TH FLOOR PC # 13041-10000-35872ADDITION OF GENERATORS AND PANELS  PC # 13041-10000-35626	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35755	17041-20000-29082	12510 S MENLO AVE	90044	15	081B197   161	6117015014	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Expired	10/12/2023 12:00:00 AM	PIN	33.9192271	-118.28876727	Plan check for solar pv system, roof-mounted on SFD.5kW ungrounded system. (22) 275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35756	18041-20000-44434	9712 W HEATHER ROAD	90210	4	147B161    16	4352002039	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.10286	-118.40782	PV1.  Install 24.705 kW roof mounted grid tied PV system.  (81) modules with (2) 7.6 and (1) 5.2 kW rated string inverters.Fees $0.00 due to California Senate Bill 1222 and AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35757	13041-10000-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	Replacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35758	14041-10000-22916	2160 N LAKE SHORE AVE	90039	13	145-5A211 287	5420008002	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Apartment			08/22/2014 12:00:00 AM			Reviewed by Supervisor	09/10/2014 12:00:00 AM	ADDRESS	34.0924	-118.25255	PV1, INSTALL 2.5 ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: CANADIAN SOLAR CS6-250PX(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35759	19041-10000-10150	17322 W KESWICK ST	91325	12	186B133   117	2202009016	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.20953	-118.51066	PC FOR ROOFMOUNTED PV ON SFD. SCOPE INCLUDES ADDITION OF MODULES AND INVERTER TO EXISTING SYSTEM. TOTAL ADDED SIZE OF 18 MODULES AND 5.0 KW INVERTER. TOTAL NEW ADDED SIZE 5.6KWDC 5.0KWACTOTAL NEW SYSTEM SIZE 13.43 KWDC 12KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35760	19041-20000-38669	5450 W WASHINGTON BLVD	90016	10	126B177  1515	5063013016	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.03799	-118.3621	TENANT IMPROVEMENT FOR AN OFFICE P.C FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35761	15041-10000-14201	7706 N CLYBOURN AVE	91352	2	189B177   851	2466030016	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.21073	-118.36336	Energy plan check for an auto repair garage by removing HID lighting and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35762	16041-20001-19187	7054 N VAN NOORD AVE	91605	2	183B161   292	2327018012	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.19917	-118.4148	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing system. Addition system size is 3 kWac for a total system size of 6.6 kWac. Addition consists of (1) inverter, (1) load center, and (10) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35763	18041-10000-01009	601 N QUAY AVE	90744	15	030B209   517	7423014041	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	33.77764	-118.25852	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 171275 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35764	17041-20000-36600	4537 N CEDROS AVE	91403	4	168A149   154	2265001239	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.15412	-118.45319	INSTALLATION OF BATTERY STORAGE AND ROOFMOUNTED 0.5 KW PV SYSTEM.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35765	13041-10000-36250	801 S FIGUEROA ST 20TH FLOOR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.04789	-118.26153	PLANCHECK FOR T24 ENERGY ONLY. NO CHANGE IN OCCUPANCY. OFFICES. HIGH RISE. 20TH FLOOR. 4928 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35766	17041-10000-21564	10 N UNIVERSAL CITY PLAZA	91608	4	162B177   352	2424044020		South Valley				1437.00	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM				Title 24 plan check.  Installation of two new subpanels and one 30 kVA transformer to feed new boiler units on 36th floor of existing commercial high rise.  New connected load < 400 amps.  Electrical permit was pulled under application number #15041-10000-27875 but scope of work was reduced.  This application is for new permit for the reduce scope due to the significant redesign of the project. New lighting in boiler room and substation room.  Lighting area = 739 sq. ft.       Building permit #15016-10000-22181	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35767	13041-20000-03152	13616 W VICTORY BLVD	91401	2	180B157   959	2330012022	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Info Complete	03/27/2013 12:00:00 AM	ADDRESS	34.1865	-118.42995	CHANGE USE & TI OF TENANT SPACE.  Change medical office & ____ to office. Add and remove partitions and finishes. Combine two tenant spaces.  New tenant spce __ x ___.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35768	17041-10000-45955	7755 N SEPULVEDA BLVD	91405	6	189B145   578	2222013031	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Issued	12/22/2017 12:00:00 AM	ADDRESS	34.2117	-118.4664	REPLACE METAL OUTDOOR HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35769	18041-20001-07102	7605 N ROYER AVE	91304	12	186B097   216	2014033010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.20862	-118.62794	03/29/2018 Supplemental plan check for the addition of a performance meter to the SLD, per inspector's request. PV system was previously permitted using the online permitting system.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35770	13041-20000-03416	1100 S GLENDON AVE #905	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.06074	-118.44418	Change to lighting and receptacles in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35771	14041-10001-25329	624 S GRAND AVE 29TH FL	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	T24 plan check over the counter of men's/women's restroom.building permit #: 14016-10000-11929 (((pulled june 23, 2014)))(REMODEL MEN'S/WOMEN'S RESTROOMS ON THE 29TH FLOOR.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35772	14041-10000-16720	11111 W SANTA MONICA BLVD Suite 910	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.04771	-118.44481	Title-24 plan check only.  Total area = 2,306.4 sq. ft.TI to existing commercial highrise.  Replace lighting using existing circuits and move wall partitions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35773	14041-10000-35268	889 S FRANCISCO ST	90017	14	129A207   100	5144023042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			12/19/2014 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.04769	-118.26404	Plan check for power and lighting. Core-and-shell for a new 38-story residential building.  Service size is (2) 1,200 amp services.308 residencies on 32 floors with 6-story podium, pool deck, and 7 levels of parking. Total lighting area = 331,642 sq. ft. Building application submitted prior to July 1st, 2014. Title 24 forms reflect this and are the 2008 Nonresidential Compliance Forms. Building application is filed under 13010-10000-03024.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35774	10041-10001-23340	5755 W 96TH ST	90045	11	093B169   128	4125021024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			Corrections Issued	03/03/2011 12:00:00 AM	ADDRESS	33.94955	-118.38214	New manufacture. New panel and circuits. EPC is for power and energy. (Bldg#5755)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35775	17041-20000-45014	1400 N IVAR AVE	90028	13	147A187   585	5546015048	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Issued	12/14/2017 12:00:00 AM	ADDRESS	34.09633	-118.32867	Installation of new 400 kW standby generator.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35776	13041-10000-36159	2840 W SAN FERNANDO ROAD	90065	1	150B213    59	5457003018	[Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.11065	-118.24419	PV2, Install roof mounted solar array system for an office with two building under one address. Interconnect with existing service 400 amp.(15)Transformered Inverters :Power One PVI-10.01-208V. (660) modules: REC PEAK ENERGY REC 250PE.ROOF #1: 28 strings with 308 modules, ROOF #2: 32 strings with 352 modulcheck if the owners are the same.   no fees due to senate bill1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35777	11041-10001-06952	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	Delta 1 modification on page E-01, single line of MSB,  modified to show correct bus ampacity ratings, and to show that the new section supplying CH-1 and CH-2 is to be rated 2500 amperes with a 2500 ampere bus extention to the 5000 ampere MSB incoming bus.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35778	19041-10000-50096	9606 W GREEN VERDUGO DR	91040	7	204B185   102	2545004008	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	06/28/2021 12:00:00 AM	ADDRESS	34.25435	-118.33993	PER AB# 1414 & SB# 1222 $0.00 FEES.NEW SOLAR SYSTEM ON A GROUND MOUNTED STRUCTURE USING CENTRAL INVERTER AND 6.7 KW DC COUPLED BATTERY SYSTEM. (24) MODULES (1) 7.6 KWAC (PIKA ENERGY )INVERTER. TOTAL 7.6KWAC/8.64 KWDC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35779	19041-10000-42197	800 E 62ND ST	90001	9	105B205   804	6007010007	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Closed	12/29/2022 12:00:00 AM	ADDRESS	33.98311	-118.26135	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR/OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35780	14041-20000-25120	12658 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97735	-118.41444	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.38 KW INTERCONNECTED WITH MSP FOR UNIT 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35781	17041-10000-00917	11017 1/2 S MAIN ST	90061	8	088-5A203 360	6074017004	C2-1	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	33.9351	-118.27403	T-24 TO AN EXISTING COMMERCIAL SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES ONLY. TOTAL SQ. FT. 790.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35782	14041-20003-03328	7722 N RESEDA BLVD	91335	12	189B125   819	2102021039	R3-1, RD5-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.21126	-118.53586	((expedite fees)))change in system design. changes include: 1 less inverter, point of interconnection to 1 phase service, deduction in number of modules, new roof layout. new system size is now 42.8kw ac. total number of modules is now 160.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35783	14041-10001-23585	3157 N HUTTON DR	90210	5	156B157   162	4385024015	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	34.12577	-118.42954	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1 , INSTALL 13080 W DC SOLAR ARRAY ON A HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. UPGRADING SERVICE PANEL.(40) MODULES: SUNPOWEWR SPR-E20-327(2) INVERTERS:SMA SMERICA SB6000TL-US-22-240>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35784	13041-10000-29577	9110 N CREBS AVE	91324	12	198B121   771	2763021052	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.23597	-118.54401	PV1.  Install 9.75 kW DC roof-mounted solar array, interconnect with main service panel.   Inverter: Fronius IG Plus V 7.5.  39 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35785	14041-10000-31644	14601 W VENTURA BLVD	91403	4	166-5A151  87	2265005011	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.15149	-118.45104	Energy plan check for a Wells Fargo bank T.I based on 2008 standard. Total area  covers 6097 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35786	14041-10000-15687	828 N KENMORE AVE	90029	13	141B197    22	5538014009	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.08673	-118.29688	PV1 4.59KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(18)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35787	18041-10000-41476	10250 W SANTA MONICA BLVD 2610	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK, COMBINING 3 TENANTS SPACES TO 1 TENATS SPACE FOR USE AS A RESTAURANT/HAIDILAO HOT POT. SCOPE OF WORK INCLUDES NEW PANELS, CIRCUITS AND LIGHTING. TOTAL SQ. FT. 8108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35788	14041-10000-33663	5633 N RIVERTON AVE	91601	2	174B177   438	2415008016	R2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Issued	12/04/2014 12:00:00 AM	ADDRESS	34.1731	-118.36606	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35789	14041-10001-08657	3148 N FOND DR	91436	5	159B141   339	2293014012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM			PC Approved	07/01/2014 12:00:00 AM	ADDRESS	34.13179	-118.48338	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U & SE3800A-US-ZB(42) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35790	19041-10000-36293	710 E D ST	90744	15	030B209   968	7424016043	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	33.77449	-118.25375	RMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR/OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35791	10041-10000-06329	8919 S SEPULVEDA BLVD UNIT 109	90045	11	096B165  1057	4122036029	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	33.9554	-118.39645	"TI IN AN EXISTING COMMERCIAL SPACE IN UNIT # 109 IN ""WACKY WOK"".  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS. PERMIT IS FOR A NEW PANEL AND NEW CIRCUITS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35792	13041-10000-19473	3165 W 11TH ST	90006	10	129B193   562	5080009020	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			07/23/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.05094	-118.30825	NEW BUILDING. 2 STORY APARTMENT 4 UNITS. SERVICE SIZE 400A. TITLE 24 PLAN CHECK ONLY 4505 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35793	11041-10000-13154	2457 S LINCOLN BLVD	90291	11	108B149  1001	4237029016	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	33.99301	-118.45107	MCDONALDS TI EXTERIOR and interior title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35794	16041-10000-23257	1224 W 81ST PL	90044	8	099B197  1121	6033010029	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	33.96499	-118.2969	NEW PV1 SOLAR SYSTEM. INCLUDES 12 MODULES AND WITH 3.8 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35795	14041-10000-34294	12021 W VOSE ST	91605	2	183B165   111	2321003034	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.19855	-118.39511	T24 ONLY. REMOVE HID LIGHT FIXTURESE  AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3764 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35796	17041-10000-05660	20580 W NATOMA ESTATE DR	91364	3	165A111     8	2174010029	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.14732	-118.58233	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.44KWdc / 9.0KWac.(36)MODULES-SOLARWORLD SW 290(36) ENPHASE M250-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35797	18041-20000-43283	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.04166	-118.26677	ti to a first time tenant.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35798	11041-10000-06839	555 W 5TH ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM			PC Approved	04/06/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	ALTERATIONS IN A BANKPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35799	15041-10002-43830	24105 S FRAMPTON AVE	90710	15	039B197    42	7439011038	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	33.805	-118.29924	"06/11/16Changes to an approved set of plans. All changes are clouded under delta 2. Scope includes relocating electrical equipment between panels, changes on home runs, and on single line diagram. (((((TI IN AN EXISTING COMMERICIAL BLDG. Existing1000 A Service, New panels, 2 @ new 75KVA transformers. Total sq ft = 13180  -  ""COMPLY WITH DEPARTMENT ORDER effective date05/14/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35800	13041-20001-29383	19300 W RINALDI ST SUITE O	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	34.27414	-118.55457	PLAN CHECK FOR FIRST TIME TENANT ON 800A SERVICE. 2400SQRFT. PLAN CHECK FOR POWER AND ENERGY(((pc for changes to T24 ltg forms and Demand reading on 800A switchgear))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35801	16041-10000-40792	350 S GRAND AVE 31ST FLOOR	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	TENANT IMPROVEMENT WORK ON 2,115 SQ. FT. OF EXISTING CORRIDOR.  NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35802	16041-20000-13248	350 S GRAND AVE Floors 46-50	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Expired	08/28/2018 12:00:00 AM	PIN	34.05160512	-118.25169569	TI to (E) commercial office highrise building tenant spaces.  Floors 46 thru 50.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35803	17041-10000-19811	522 N HOOVER ST	90004	13	141A201   220	5401009050	C1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1959.03	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.08026	-118.28428	PC FOR PV SYSTEM ROOF MOUNTED. SYSTEM USES 11 MODULES AND 3KW AC RATED INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35804	13041-20001-26116	225 N CAROLWOOD DR	90077	5	141B157   408	4358005027	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.08188	-118.42612	((EXPEDITED FEES))PV1 CENTRAL INVERTER. TOTAL 11.42KWAC SYSTEM. 36 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35805	14041-10000-32855	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.07583	-118.37407	Plan check for power and energy. T24. Total area = 1694 sq. ft.   Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35806	18041-10001-27436	7634 W WYNGATE ST	91042	7	204B197   583	2558007029	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1011.10	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM			Reviewed by Supervisor	07/30/2018 12:00:00 AM	ADDRESS	34.25735	-118.29909	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35807	13041-10000-24322	6600 N TOPANGA CANYON BLVD #185	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING. TENANT IMPROVEMENT. REFERENCE BUILDING APPLICATION 13016-10000-17912.CUT SHEET FOR ALL LIGHTS AND CURRENT LIMITING DEVICES ARE  SUBMITTED .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35808	16041-10000-02499	6333 W 3RD ST STALL 110	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.07157	-118.36014	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTUARANT/BAR.  SCOPE INCLUDES ADDING NEW LIGHTING TO AN OUTDOOR STEEL COVERED DINING AREA ON GROUND FLOOR.TOTAL AFFECTED AREA IS 760 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35809	11041-20000-06650	1888 CENTURY PARK EAST 7TH FLR	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	08/02/2011 12:00:00 AM	PIN	34.06139499	-118.41373129	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT ON 7TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35810	19041-20000-47899	9300 N BIANCA AVE	91325	12	198B129   219	2766017007	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.23974	-118.51402	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 4.34 KW DC/3.36 KW AC. SCOPE OF WORK CONSISTS OF (14) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35811	17041-20000-06006	8106 W 3RD ST	90048	5	138B177   751	5511029035	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.07197	-118.36625	ti to an existing commercial space.  adding new lighting new controls to existig panels.  plan check for energy only.  total square feet 1332	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35812	13041-10000-34666	2137 S WESTWOOD BLVD	90025	5	126B153   239	4322001019	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.0442	-118.43229	Remove HID light fixtures and replace with new fluorescent fixtures in existing retail space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35813	16041-10000-24390	1001 E 60TH ST	90001	9	105B209    58	6007004010	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	33.98579	-118.2586	PC FOR ENERGY ONLY. REPLAEMENT OF HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 27280 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35814	18041-20000-14836	20622 W WALNUT CIR	91326	12	219B109   358	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.29371	-118.58322	PC for rooftop solar for 3.84kW(ac)/4.02kW(dc) for SFD tract home. Installing 12 AC modules with AC disconnect.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35815	16041-20002-08448	13630 W SATICOY ST	91402	6	186B157   140	2214025004	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM			PC Approved	02/01/2017 12:00:00 AM	ADDRESS	34.20928	-118.42941	[[2/1/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. CHANGES ARE CLOUDED. REMOVING A DISCONNET, INSTALLATION OF A 400AMP PANEL, ADJUSTING FEEDER SIZES AND DERATE CALCULATIONS]]]]Plan check for PV system on conbination of roof mount and new carport in existing roof. Total system size: 302.2kW with 828 modules and 6 inverters(STP24000TL-US) and 2 inverters(STP2000TL-US) connect to supply side tap.     low fees due to senate bill1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35816	16041-20000-23084	13213 N MIRA MAR DR	91342	7	225B165    19	2580018***	RD6-1XL	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Expired	08/31/2018 12:00:00 AM	ADDRESS	34.31289	-118.40476	Plan check for PV roof mounted system. System size: 6.0kW with 18 modules and 1 inverter(6.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35817	13041-10003-07125	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			11/06/2014 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.04594	-118.25757	((((((((((((((((    m.z  NEW TITLE 24  11-6-14 , ALL LIGHTS CHANGED.)))))))))))))))      7-STORY MIXED USED BUILDING 700 UNIT APARMENT, OVER 2-LEVEL SUBTERRANEAN GARAGE :  upper 6 levels residential and retail/gym on the 1st floor. None highrise.. 5000A SERVICE;__this note : by Nabil, this methane zone.  was indicated the level changed from 5 to 2.  see plan number 12041-10000-29828	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35818	13041-10000-34552	1204 S PALOMA ST	90021	14	123A211   221	5132016047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.03097	-118.24778	title 24 and emergency lighting for retail stores , two story , emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35819	10041-10001-08905	12811 S FIGUEROA ST	90061	15	081B201   272	6132003030		Harbor				2911.20	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM			PC Approved	06/30/2010 12:00:00 AM	PIN	33.91597635	-118.28400452	PC only. Change the priviously approved plan. Change the type of lights. Plan check for change.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35820	15041-20000-22587	7607 COURAGE WAY	91405	6	186B145  1154		(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20886341	-118.46444926	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35821	19041-10000-53498	7378 W PERIGORD CT	91042	7	210B197   517	2552048004	R1-1, RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Issued	01/22/2020 12:00:00 AM	ADDRESS	34.27163	-118.29428	0$ Final Fees per AB1414PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 60  (REC290TP2) MODULES, 60 (SE320) OPTIMIZERS, 2 SOLAREDGE INVERTERS (SE11400H-US & SE3800-H-US),  CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. DERATED MAIN BREAKER.  SYSTEM SIZE: 17.40KW DC, 15.20KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35822	14041-10001-08935	9463 N BEACHY AVE	91331	6	198B157   224	2642017028	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/12/2014 12:00:00 AM	ADDRESS	34.24176	-118.43178	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35823	13041-20000-10558	1888 CENTURY PARK EAST FLR 10	90067										Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM			PC Approved	04/24/2013 12:00:00 AM				Plan check for energy and emergency lighting. 10th floor of commerical highrise. Gursey Schneider LLP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35824	13041-10000-35067	6960 S CENTINELA AVE	90230	11	105B165   480	4220014057	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	33.9837	-118.39937	New 11850 Sq. Ft. 3-story commercial building located in Methane Zone (Core and Shell).  New 800A, 120/208V, 3Ph, 4W service. Install lighting in garage, common, and outdoor areas.  Other temporary lighting install in unoccupied spaces are not in the scope of core and shell plan check.  Plan check for power and energy. Note: Variance is filed to separate fire alarm and methane mitigation systems filed 05/15/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35825	19041-20000-04564	602 W PARK ROW Unit B	90012	1	139-5A217  71	5415030015	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural	Yes	2060.10	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Issued	02/07/2019 12:00:00 AM	ADDRESS	34.07672	-118.2314	Plan check for PV roof mounted system, PV system size: 2.1KW with 6 AC Modules. connected to 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35826	11041-10000-19892	900 S BROADWAY	90015	14	127-5A209 247	5139002018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM			PC Approved	11/02/2011 12:00:00 AM	ADDRESS	34.04213	-118.25602	INTERIOR REMODEL OF EXISTING RETAIL SPACE FOR 7-ELEVEN.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35827	14041-10000-22464	333 S GRAND AVE 4070	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT -  FOR NEW OFFICE SPACE AND  REMODEL (E) RESTROOMS.1695 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35828	14041-10000-07341	12450 W MONTAGUE ST	91331	7	204B165   350	2537014049	M2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.25285	-118.40386	TI. NEW LIGHTING FOR A STORAGE EPC IS FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35829	17041-10000-36418	2243 N PRINCETON AVE	90026	13	145-5A211 308	5443018019	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.09212	-118.24769	Install new rooftop solar on an SFD, 1.16 kW DC, (4) microinverters with (4) modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35830	19041-20000-11645	1934 S BARRY AVE	90025	11	126B149  1079	4262027034	R2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.03836	-118.44976	INSTALLATION OF A NEW ROOFTOP PV SYSTEM ON EXISTING RESIDENTIAL BUILDING. TOTAL SYSTEM SIZE IS 9.9KW DC/9.45KW AC/9.11KW AC CEC. SCOPE OF WORK INCLUDES (30) PANASONIC PV MODULES WITH ENPHASE ENERGY IQ7X-96 MICRO INVERTERS,  A 100A COMBINER BOX, AND A 5KW TESLA POWER WALL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35831	12041-10000-17687	5250 N LANKERSHIM BLVD	91601	4	171B173   367	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.16668	-118.37545	Change to lighting and receptacles to an existing office space in a high rise building.  Load is less than 400A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35832	17041-10002-16616	8700 W BEVERLY BLVD Davis Bldg-G-140	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Closed	04/27/2018 12:00:00 AM	ADDRESS	34.07666	-118.3805	Supplemental for changes to approved set. Adding new receptacles in MRI room for cedars cinai medical center. Changes clouded delta 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35833	16041-10000-06097	118 S AVENUE 50 BUILD. 3	90042	1	150A225   277	5467014008	R3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.20	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.1042	-118.20184	PLAN CHECK FOR NEW CONDOMINIUM PROJECT BLDG 3, 8 UNITS, 600MSA. T-24 for LTO only. TOTAL TITLE 24 LIGHTING AREA: 2,098 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35834	19041-10000-48059	7691 N SAN FERNANDO ROAD	91505	2	186B177   564	2466036***	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.20829	-118.3558	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35835	19041-20000-14893	4758 W BONVUE AVE	90027	4	153B197   302	5588017008	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.11445	-118.29464	PLAN CHECK FOR INSTALLATION OF A (3) 13.5 KWH TESLA POWERWALL BATTERY BACK UP ENERGY STORAGE SYSTEM FOR A EXISTING SFD WITH EXISTING PV SYSTEM. ALSO INCLUDE 1 200A SUB PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35836	19041-10000-20741	100 S BARRINGTON PL PH 2	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.06664	-118.46903	PLAN CHECK FOR ENERGY ONLY. TI: REMODEL OF EXISTING CLASSROOMS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. PHASE 2 TI. TOTAL SQ. FT. 3584.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35837	15041-10000-18208	1776 S ROBERTSON BLVD	90035	5	129B169  1180	4303005037	C2-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.0473	-118.38576	Plan check for new fire alarm system located at a 2-story commercial building with (1) fire alarm panel, (1) annunciator panel, (1) power supply, and (35) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35838	13041-20000-21714	9671 N VANALDEN AVE	91324	12	201B121   444	2762006002	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.24683	-118.54935	PV1 TRANSFORMERLESS SYSTEM. 30 PANELS AND 2 INVERTERS. TOTAL SYSTEM SIZE 12.0 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35839	09041-10003-07273	5557 E VALLEY BLVD	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Public Safety Only			12/15/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.07723	-118.16241	Suppl. Plan Check and Permit for the changes to approved plans and additional devices to the Fire Life Safety System in the building #330  per Delta 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35840	14041-20000-17347	18911 W NORDHOFF ST #38	91324	12	198B121   737	2762015004	(Q)P-1VL, QCR-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.23566	-118.54519	TI to (E) commercial office space for dental office.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35841	19041-10000-18376	1422 N DEVLIN DR	90069	4	144B169    44	5560001023	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM			PC Info Complete	08/05/2019 12:00:00 AM	ADDRESS	34.09493	-118.3872	NOTE: PERMIT FEES ARE $0 DUE AB 1414.(ePlan) PLAN CHECK FOR ROOF MOUNTED 24KVA BALLASTED PV USING 3 INVERTERS(RADIAN-GS8048A), 65 MODULES (LG330N1C-A5-330W), WITH 3 ENERGY STORAGE SYSTEM (BLUEPLANET ENERGY BLUE ION 2.0 B12-16-18U)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35842	19041-20001-06872	8700 S PERSHING DR	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Expedited plan check fee.PV2.  Install 24.84 kW DC / 22.62 kW AC roof mounted grid tied PV system.  (70) modules with (1) 20 kW rated string inverter.System 6 of 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35843	15041-20000-02383	8019 N DE SOTO AVE	91304	3	189B109   325	2109005010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Expired	02/20/2017 12:00:00 AM	ADDRESS	34.21616	-118.5887	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system.25  255W pv modules across three strings (9 and 8+8 combined).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35844	10041-10001-09480	2102 E 1ST ST	90033	14	127-5A223  98	5183008027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.20	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			PC Info Complete	07/27/2011 12:00:00 AM	ADDRESS	34.04467	-118.21366	CHANGE OF USE FROM A GYMNASIUM TO A THEATER (CASA 101 THEATER )changes made to previously approved set only transformers to tracks are changed , may need to recalculate title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35845	10041-10000-25500	2001 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	10/07/2011 12:00:00 AM	PIN	34.06587468	-118.19737837	FIRST TIME TENENTS IN A NEW 3 STORY BUILDING.  CORE & SHELL WERE APPROVED UNDER A DIFFERENT APPLICATION.  PLAN CHECK IS FOR POWER & ENERGY. VARIANCE FORM WAS SUBMITTED FOR THE FIRE LIFE SAFETY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35846	15041-10000-19672	1515 N LYNTON AVE	90744	15	036B201   547	7414022028	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	33.79278	-118.28163	pv1, install 3.8 kw ac roof-mounted solar array on a one single family home. (14) modules: et solar et-p672295(1) inverter: abb pvi-3.8-outd-us*****The applicant has changed the plan with 16 modules.(6/29/15)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35847	16041-20000-10972	11332 W OSBORNE ST	91342	7	213B173   404	2530022005	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.27704	-118.37784	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17.11 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35848	18041-20002-48715	8600 W LA TUNA CANYON ROAD	91352	7	198B189   116	2401028***	A1-1XL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM			PC Approved	04/11/2019 12:00:00 AM	ADDRESS	34.23699	-118.3204	Revision to approved set.  Equipment location changes and main disconnect rating downsize/change to quantity of main disconnects at MSP.  (((Plan check for PV roof mounted system, system size: 21.6kW DC, 18.3kW AC with 60 PV Modules and 2 inverters(11.4kW and 7.6kW) connected to 400A Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35849	16041-10000-37966	17332 W SIGNATURE DR	91344	12	216B133   427	2606014036	RA-1-H, RE15-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	11/19/2016 12:00:00 AM	ADDRESS	34.28727	-118.51222	Plan check for PV roof mounted system on single family. System size: 8.4kW with 30  modules and 30 mircoinverters Enphase 280 connected to 400A panel.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35850	15041-10000-06129	550 N FIGUEROA ST	90012	1	133-5A213  51	5407003036	C2-2D	Central	Central City	Historic Cultural		2071.01	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.06175	-118.24658	PV2, 225KW roof-mounted system including (1) Solectria SGI 225PE inverter, (15) combiner box, and (1296) INnotech Solar 260W modules interconnecting to the main service panel. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35851	18041-20000-41729	9901 N LURLINE AVE BLDG 3	91311	12	201B109    59	2741002006	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Apartment			10/31/2018 12:00:00 AM	12/16/2019 12:00:00 AM		Issued	12/16/2019 12:00:00 AM	ADDRESS	34.25058	-118.58431	New meters, power, and lighting for converted dwelling units.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35852	14041-20001-10891	18714 W VINTAGE ST	91324	12	201B121    63	2729019019	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.25086	-118.54117	Fee for expedite.*****Roof mounted PV sysem with Optimizer, system size 3.25KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35853	18041-10000-47161	20440 W VIA CELLINI	91326	12	219B109   257	2701055007	RE11-1-H, RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.29433	-118.58051	New rooftop solar system on a SFD,  system size 10kW AC, (1) 10kW SE inverter, (32) modules, (32) power optimizer P400. Main panel is split bus, and downsized main breaker from 200A to 175A (load calculation is included)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35854	19041-10000-48365	110 S BOYLE AVE	90033	14	129A221   228	5174018900	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			11/22/2019 12:00:00 AM	08/29/2022 12:00:00 AM		Issued	08/29/2022 12:00:00 AM	ADDRESS	34.04693	-118.21965	(100% AFFORABLE HOUSING)FULL PC FOR A NEW 2000A SERVICE (120/208 3P, 4W) THAT FEEDS A FIRE PUMP, ONE ELEVATOR, AND  AN 800 METER SWITCHBOARD WHICH SUBFEEDS 44 SUBPANELS. THE 2000A SERVICE ALSO FEEDS ALL RELATED DISTRUBUTION EQUIPMENT. PER BUILDING ((19010-10000-05226))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35855	16041-10001-05459	3132 E FOLSOM ST	90063	14	127-5A227 226	5178021029	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.04378	-118.19666	Supplemental to approved set: revised single line diagram to reflects the installation of the Load Center.<<PV1 roof mounted solar system interconnnected with the main service. Inverter: 3kw, (9) solar modueles. kiocera-ku2656 power optimizers.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35856	18041-20000-05905	3229 W CASITAS AVE	90039	13	153B209   540	5436002027	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM			Verifications in Progress	03/05/2018 12:00:00 AM	ADDRESS	34.11548	-118.25102	PLAN CHECK FOR TITLE 24 ONLY FOR TI - NON BEARING WALLS ON EXISTING MEZZANINE FOR NEW OFFICES AND ACCESSORY TEST LAB - TOTAL AFFECTED AREA = 1359 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35857	14041-10001-29655	525 W 7TH ST	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.04722	-118.25617	Title 24 plan check only.  Changes to approved set including changes to lighting layout and title 24 calculations.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY ONLY. CHAGE OF USE FROM RETAIL/TAKE-OUT JUICE BAR TO RESTAURANT ON GROUND FLOOR. 2720 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35858	14041-10000-03182	130 E KETCH MALL	90292	11	102A147    68	4295002055	R1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	33.97447	-118.45944	PV1.  Install 10.0 kW roof-mounted PV system, interconnect with main service panel.  40 modules: Rensola JC250M-24/Bb.  2 transformerless inverters: SolarEdge SE5000A-US and SE6000A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35859	19041-10000-47989	21150 W DUMETZ ROAD	91364	3	168B105   340	2172002002	A1-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM			Reviewed by Supervisor	12/27/2019 12:00:00 AM	ADDRESS	34.15831	-118.59156	"FULL PC FOR A NEW STRUCTURE (POOL HOUSE), SCOPE OF WORK INCLUDES TWO NEW PANELS CONNECTED TO AN EXISTING 2000A SWITHBOARD  (120/208  3P 4W). TOTAL AFFECTED AREA IS 18522 SQFT. PER BUILDING (((N) 37'3""x36'2"" L-shaped pool house with concession stand, equipment room, changing room, and restrooms for existing goft course. )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35860	17041-10001-03874	13050 W SAN VICENTE BLVD	90049	11	129B137   501	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Info Complete	03/20/2017 12:00:00 AM	ADDRESS	34.0483	-118.49125	PC FOR WALKWAY LIGHTING AND FACADE LIGHTING, PERMIT TO BE ISSUED FOR CHANGE OF ADDRESS. THIS IS FOR COMMON AREA LIGHTING SALES FRONT. NO UNIT ATTACHED. PC OFR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35861	19041-20000-28989	8414 N FUSION WAY	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Issued	08/19/2019 12:00:00 AM				new sfd 800 amp service.  plan check for power only. permit fees paid under application number 18010-20000-05038.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35862	14041-20001-23957	10230 N COZYCROFT AVE	91311	12	204B109   225	2741025026	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.25619	-118.58171	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 12.7KW AC USING 53 MODULES. USING ENPHASE M250. MICROINVERTER SYSYTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35863	19041-10000-13731	1001 N SEWARD ST	90038	4	144B185   940	5532024007	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.08914	-118.33334	PC FOR FA PROPOSED 5-STORY OFFICE BUILDING WITH ONE LEVEL OF BASEMENT PARKING. SCOPE INCLUDES (1)  FACP , (2) CONTROL PANEL,  AND (128) FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35864	11041-20000-07501	11333 N SEPULVEDA BLVD	91345	7	213B145   166	2664001801	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1092.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Closed	05/18/2011 12:00:00 AM	ADDRESS	34.27646	-118.46863	underground conduit only permit	N	N	Express Permit	06/10/2024 12:00:00 AM
35865	13041-10001-34475	6256 N TOPANGA CANYON BLVD BLD # C&D	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	Changes to an approved set of plans. Changes include relocating load circuits. No new circuits or panels added. All changes are clouded. Approved for submittal per F.Y.***** Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING C AND D.BUILDING PERMIT # 13010-10000-02906.New 2 STORY retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35866	19041-20000-15328	15253 W GOLDEN CT	91342	7	219B145   688	2611041026	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Issued	04/25/2019 12:00:00 AM	ADDRESS	34.29481	-118.46533	PLAN CHECK FOR THE ADDITION OF (2) 200A LOAD CENTERS AND A 13.5 KWH TESLA POWERWALL BATTERY BACK UP TO EXISTING SFD WITH A EXISTING PV SYSTEM AND EXISTING ENERGY STORAGE SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35867	14041-20000-10263	6636 N HESPERIA AVE	91335	3	180B125   315	2122029018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.19143	-118.52611	PV1 INSTALL ROOF  MOUNTED PV SYSTEM INTERCONNECTED WITH MAIN PANEL SIZED 6.1KW WITH TRANSFORMERLESS INVERTER (1) SOLAREDGE SE6000A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35868	16041-10000-42276	1035 S WESTWOOD BLVD	90024	5	132B149    41	4363018029	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.06181	-118.44575	T-24, TENANT IMPROVEMENT IN EXISTING RETAIL SPACE SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL SQ FT 1503.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35869	18041-10000-12758	4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	33.99045	-118.44372	NEW FIRE PROTECTION SYSTEM FOR 5-STORY MIXED USED BUILDING. (1) FA PANEL,  (5) POWER SUPPLY,  (222) DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35870	18041-10000-03457	11601 W WILSHIRE BLVD #360	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC for T24 only for office remodel. Installing new lights, receptacles and lights. Total area is 1930sqft. B# 17016-20000-35205	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35871	17041-10000-42181	1217 S OCEAN FRONT WALK 1-35	90291	11	108A143   383	4226005004	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Public Safety Only			11/21/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	07/27/2021 12:00:00 AM	ADDRESS	33.98864	-118.47504	NEW FIRE WARNING SYSTEM FOR A  36 UNITS  APARTMENY-HOTEL BUILDING. Scope includes (1) fire alarm panel, (2) power supplies and (206) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35872	18041-10000-00099	20720 W SUPERIOR ST	91311	12	201B109   233	2748003089	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.24625	-118.585	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35873	18041-10000-09375	2110 W SUNSET BLVD #M	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.07735	-118.26408	PC FOR T.I. FOR (E) MEDICAL OFFICE. SCOPE INCLUDES NEW EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 2753 SQ.FT. B# 18016-10000-0378ORIGINAL CORE & SHILL UNDER PERMIT 17016-10000-35656.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35874	18041-10001-09282	8304 S RAYFORD DR	90045	11	096B157   318	4114032013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	33.96163	-118.42301	04/16/2018 PC ONLY FOR CHANGES TO AN APPROVED SET. CHANGES INCLUDE PANEL UPGRADE TO 200A UNDER DELTA 1. CHANGES ARE ON PV-1, PV-2B, AND PV-3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35875	16041-20000-37385	21650 W OXNARD ST ste 700	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti to an existing commercial building high rise office building.  adding new lighting new controls to existing panels.  plan check for energy and em lighing.  scope in suite 700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35876	14041-10000-04773	1056 S FREDERICK ST	90291	11	111B145  1707	4243003053	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			02/20/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	33.99912	-118.46	Lincoln place apartment building project. new 2-story apt. building with 8 units. addition of three E.V system and one sub panel and meter is added to existing section.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35877	13041-10000-03198	380 W WORLD WAY T63	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	FIRST TIME TENANT IN SPACE T63 FOR TOM BRADLEY TERMINAL OF LAX. USE OF SPACE FOR RETAIL PURPOSE. PC FOR ENERGY AND POWER. TOTAL SQ FT 1341	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35878	19041-10000-52804	5340 S ALLA ROAD STE 120	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	08/17/2020 12:00:00 AM		Issued	08/17/2020 12:00:00 AM	ADDRESS	33.9773	-118.42567	PLAN CHECK FOR TITLE 24 ONLY. SCOPE OF WORK INCLUDES NEW LIGHTHING FIXTURES TO AN EXISTING SPACE. TOTAL AFFECTED AREA IS 16662.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35879	17041-30002-06410	445 S FIGUEROA ST Suite 3600	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.05295	-118.25675	05-02-2017 Changes to approved set. Changes include change of fixture type and size. Permit to be pulled under master application.Plan check for Title 24 only. Project site is a portion of the 36th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,325 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35880	14041-20001-05229	5809 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	33.97382	-118.41992	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35881	18041-20000-01337	4917 N TOPANGA CANYON BLVD	91364	3	168B101   442	2170011004	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.15734	-118.60613	ti to an existing commercial building. adding new lighting new controls to existing panels.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35882	19041-10000-46482	11696 W VENTURA BLVD	91604	2	162B169   403	2369028028	C2-1VL-RIO, R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.14106	-118.38761	Plan check for Fire Alarm System, system consists of 42 Devices and 1 FACP. ***permit under 19041-10000-23529***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35883	15041-20001-15051	11415 N ILEX AVE	91340	7	213B153   192	2616018019	M1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.27705	-118.43569	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. Ssytem size is 30 kWac and consists of (3) inverters, (140) modules, (140) power optimizers, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35884	17041-10003-38362	1601 N GENESEE AVE	90046	4	147B177   623	5551014009	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.10007	-118.35842	Supplemental PC for changes to approved. Upsizing home backup panel MCB to 200A and connecting to 400A split bus Main panel. All changes clouded under delta 1. ZERO FEES DUE TO PV SENATE BILL 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35885	19041-10000-35366	2913 W EXPOSITION PL Units 2	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02048	-118.32811	Plan check for a PV2 2.56kw DC / 3.0KW AC roofmounted system. Scope includes (8) modules and (1) inverter interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35886	17041-20001-35662	114 S OXFORD AVE 1-35	90004	10	138B193  1029	5517009034	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Apartment			10/04/2017 12:00:00 AM			PC Approved	11/17/2017 12:00:00 AM	ADDRESS	34.07317	-118.30776	expeditepv2install roof mounted pv system sized 13.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35887	15041-20000-02805	12468 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	33.97899	-118.41015	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35888	16041-30001-12160												Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM			Reviewed by Supervisor	04/19/2016 12:00:00 AM				void application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35889	17041-20000-37230	13920 W VAN NUYS BLVD 104-105	91331	6	204B153   484	2645001027	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.25584	-118.43585	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35890	19041-10000-13716	7530 N SAN FERNANDO ROAD	91352	2	186B181   181	2405008035	[Q]CM-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1021.05	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM			PC Info Complete	08/08/2019 12:00:00 AM	ADDRESS	34.20869	-118.35273	T-24 PLAN CHECK FOR A TI OF AN EXISTING LIGHT INDUSTRY. CHANGE OF USE TO AN AGRICULURE BUISNESS FOR QUALITY TESTING ONLY. NO CHEMICAL PROCESSES PER APPLICANT CLARIFICATION. SCOPE INCLUDES 1 NEW 75KVA TRANSFORMER AND 3 NEW PANELS. CONNECTED LOAD LESS THAN 400A. TOTAL AFFECTED AREA IS 2792 SQ.FTB# 19016-10000-10655APPROVAL IS SUBJECT TO BUILDING APPROVAL.All pages are signed to be stamped when and approved when provided with an issued building Permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35891	18041-10000-25318	700 W 7TH ST 310-320	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.04797	-118.25815	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR (2) TENANT SPACES. PERMFORMANCE METHOD OF COMPLIANCE FOR T24. 2846 SQFTBUILDING PERMIT # 18016-10000-09729 (N) PARTITIONS AND STOREFRONTS FOR RETAIL SUITES S310 AND S320	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35892	19041-20000-08201	10306 N SEPULVEDA BLVD	91345	7	204B145   287	2649019008	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.25772	-118.46706	Plan check for power and energy. Project site is an existing commercial bulding. Project scope is a change of use from medical to dental office. Total lighting area = 2,998 sq. ft.Note: Partial electrical fees have been paid for under 19041-90000-07560. The building permit has been issued under 18016-20000-33487	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35893	13041-10000-31962	359 S LA BREA AVE	90036	4	135B181   359	5508001031	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.06719	-118.34433	first tenant in commercial space-la boulange-bakery/coffee shopNOTE THAT CORE / SHELL PLANS  13041-10000-26174 PENDING CORRECTIONS 10/04/13	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35894	17041-20000-00682	550 E SAN JUAN AVE	90291	11	108B145   842	4239026037	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	33.99275	-118.46766	Plan check for a PV1 roof-mounted PV system. System size is 24.1 kWac and consists of (67) AC PV modules and (1) load center.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35895	19041-10000-05752	12055 W WICKS ST	91352	6	195B165    81	2631005037	RA-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.23273	-118.39575	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35896	15041-20000-41337	1316 N WESTERN AVE	90027	13	147A193   240	5544031018	C2-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Closed	04/01/2016 12:00:00 AM	ADDRESS	34.09543	-118.30905	TI to an (E) office. PC for Energy only. Total area: 3,373 sq.ft((Tenant Improvement: construction of non bearing partitions in (e) office space.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35897	11041-10000-15313	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	2951.01	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.77884	-118.29327	NEW MV MOTOR CONTROLLER AT CONOCO OIL REFINERY, IN A NON-CLASSIFIED AREA PER APPLICANT.  PLAN CHECK IS FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35898	19041-10000-27727	304 S BROADWAY 2ND FLR	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.05076	-118.248	FULL PC FOR POWER AND ENERGY. TI NEW OFFICES ON THE 2ND FLOOR OF AN EXISTING BUILDING. SCOPE INCLUDES NEW CIRCUITS, AND RECEPTACLES. CONNECTED NEW LOAD > 400A.TOTAL AFFECTED AREA IS 12650 SQ. FT. B19016-10000-16174	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35899	15041-20000-39000	7700 W SUNSET BLVD	90046	4	147B177  1007	5551023023	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			Reviewed by Supervisor	12/01/2015 12:00:00 AM	ADDRESS	34.09788	-118.35739	PV2.  Install 143.64 kW roof-mounted, utility-interactive PV system for 2-story commercial office building.  (504) Solarworld 285W modules w/ (12) SunnyBoy 11000TL-US-12.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35900	11041-10000-18483	7111 W MELROSE AVE A-C	90046	5	141B181   555	5525009022	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			Corrections Issued	10/19/2011 12:00:00 AM	ADDRESS	34.08361	-118.34463	TI TO AN EXISTING RESTAURANT.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35901	16041-10001-11127	1824 N HILLHURST AVE	90027	4	150B201  1276	5590018001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.10439	-118.28725	PC FOR CHNGES TO APPROVED SET. SCOPE INCLUDES CHANGE TO SERIES RATED EQUIPMENT AND BREAKERS. PC FOR POWER ONLY. SCOPE INCLUDES UPGRADING SERVICE AND SWITCHBOARD TO A 600A 120/240V 1PH 3WIRE FOR AN EXISTING COMMERCIAL BUILDING (CORE & SHELL ONLY). NO CONNECTED LOAD AT THE MOMENT, EACH TENANNT WILL SUBMIT TI INDEPENDENTLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35902	14041-10000-27416	1833 W HILL DR	90041	14	163-5A225  66	5669002004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Expired	10/27/2016 12:00:00 AM	ADDRESS	34.14359	-118.20757	Installation of roofmounted residential solar PV standard plan. # of inverters: 1. System size: 3.8kW. # of modules: 21.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35903	14041-10000-14855	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.18088	-118.48309	PLANCHECK FOR POWER FOR TILLMAN WATER RECLAMATION PLANT. REPLACING MEDIUM VOLTAGE MSB1 AND MSB 2 ALONG WITH FEEDERS.plan check ezxtensions have been filed. last date to pull permit is 12/4/2016	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35904	19041-20000-47154	1349 N HOBART BLVD	90027	13			R3-1XL	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM			Reviewed by Supervisor	12/20/2019 12:00:00 AM	ADDRESS	34.09635	-118.30578	Plan check for power and energy 1200A service. Total area: 18,742 sq ft B#18010-10000-06260**************************************Building work description: PROPOSED 4 STORY, TYPEVA, 29 UNIT APARTMENT ***********************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35905	18041-10000-48351	1100 S GLENDON AVE 2000	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Issued	12/20/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	T24 FOR (E) HIGH RISE OFFICE SPACE, TOTAL SQUARE FOOTAGE = 1752	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35906	11041-10000-02976	6022 W AVION DR	90045	6	090B165    36	4129028900	M2-1	West Los Angeles				2780.00	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	06/23/2011 12:00:00 AM	ADDRESS	33.94182	-118.39269	"TI IN AN EXISTING COMMERCIAL AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS IN THE ""AMERICAN EAGLE ROMOTE HOLD ROOM""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35907	19041-10000-05769	18143 W PARTHENIA ST	91325	12	195B125   792	2769019903	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.2288	-118.52887	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35908	18041-10001-13577	634 N KINGMAN AVE	90402	11	124-5A133 150	4408036007	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.03522	-118.50854	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35909	10041-20000-08221	2434 S PURDUE AVE 1-24	90064	11	123B153   431	4260038036	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.03341	-118.4398	PV SYSTEM FOR APARTMENT BUILDING. 7KW SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35910	10041-10000-24309	5670 W WILSHIRE BLVD 1970	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM			PC Approved	12/07/2010 12:00:00 AM	ADDRESS	34.06222	-118.35208	Demo old lighting fixtures and install new lighting fixtures in existing spaces.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35911	17041-20000-00971	10925 W BLUFFSIDE DR	91604	2	162B173   304	2366021008	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			01/11/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.14115	-118.36774	Plan check for power only. Project site is an existing 101-unit apartment building. Project scope is the addition of laundry circuits to 86 units.Note: Building application has been generated under 16016-20000-29604	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35912	14041-10000-34554	4091 S REDWOOD AVE 1-67	90292	11	108B153   893	4230006032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	12/17/2016 12:00:00 AM	PIN	33.99096225	-118.44116852	Power plan check for new 5 story 67 unit apartment building. Two new 2000 A services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35913	13041-10000-13082	19965 W INGOMAR ST	91306	3	189B113   989	2106004030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.21205	-118.56867	PV1 7.35KW XFMR INV. 1STORY HOUSE. STD. ROOFMOUNT.  [ (1) INV: fronius ig plus v 7.5 ][ (30x) MOD: TSM-245 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35914	15041-20000-14089	3760 N GLENRIDGE DR	91423	4	162B157   730	2272027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.13898	-118.43214	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Building integrated PV panels are connected to two central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35915	18041-10000-42242	12414 W EXPOSITION BLVD	90064	11	123B149   857	4259026002	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	10/01/2020 12:00:00 AM	ADDRESS	34.03061	-118.45624	FULL PC FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT - OFFICE & MEDICAL OFFICE (3 FLOORS) FOR NEW CORE & SHELL BUILDING. SCOPE INCLUDES NEW 800A DISTRIBUTION BOARD,  NEW PANELS, NEW CIRCUITS, AND LIGHTING. TOTAL AFFECTED AREA IS 66,208 SQ. FT. B#18016-10000-28814	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35916	16041-10000-01233	6108 W AFTON PL	90028	13	147A189   198	5546021023	R3-1XL	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Expired	02/12/2018 12:00:00 AM	ADDRESS	34.09519	-118.32267	PV1, INSTALL 3.6 KW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MODULES: KYOCERQA KU2656ZPA(1) INVERTER: ABB PVI -3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35917	19041-20000-37056	10232 W CRESTA DR	90064	5	126B165   648	4308011019	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.04106	-118.40465	Plan check for PV roof mounted system, PV system size: 7.2KW DC, 6.27KW AC CEC with 20 P V modules and 1 inverter(6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35918	19041-10000-51351	384 WORLD WAY SPACE SM58	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	12/24/2019 12:00:00 AM	ADDRESS	33.94339	-118.40887	TI IN AN EXISTING COMMERCIAL AREA. INSTALLING NEW LIGHTS IN A STORAGE ROOM IN SUITE# SM58. T-24 ENERGY ONLY. COMPLETE PLAN CHECK MAY BE REQUIRED, SUBJECT TO FIELD INSPECTION. BULDING PERMIT: 19016-10000-38765	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35919	16041-10001-37601	4715 N HEAVEN AVE	91364	3	168B093   198	2074040002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM			Corrections Issued 2	10/29/2016 12:00:00 AM	ADDRESS	34.15661	-118.63216	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.099KWac / 11.00KWac.(37)MODULES-SUNPOWER SPR327NE-WHT-D(1)INVERTER-SUNNYBOY SMA SB6000TL-US-22(1)INVERTER-SUNNYBOY SMA SB5000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35920	19041-10000-27867	20231 W HAMLIN ST	91306	3	180B113   338	2134018005	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.19113	-118.57443	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 24 MODULES (Q-CELL 285) , 24 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 6.84KWdc and 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35921	15041-20000-43820	843 N VIA DE LA PAZ	90272	11	129B125   735	4412004022	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM			PC Info Complete	12/29/2015 12:00:00 AM	ADDRESS	34.04604	-118.52755	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (RETAIL SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 1244 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35922	19041-10000-31919	808 S WESTERN AVE	90005	10	132B193   736	5093008010	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Info Complete	12/09/2019 12:00:00 AM	ADDRESS	34.05732	-118.30889	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES INSTALLING A NEW 1600A DISTRIBUTION BOARD FED FROM AN EXISTING 5000A SERVICE. ADDING NEW PANELS, NEW LIGHTS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 63556 SQ. FT. ****Lost set, permit is issued under supplemental.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35923	18041-30001-17988	1800 N VINE ST 2ND FLR	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM			PC Approved	07/24/2018 12:00:00 AM	ADDRESS	34.10393	-118.3265	This is plan check only, permit is covered under master# 18041-30000-17988: Revisison to approved set of plan, noted as Delta-1. Replace corridors light fixture from 2x2 to 1x4 fixtures, floor plan, T24, and photometric are revised accordingly. <<PLAN CHECK FOR T24 ONLY, TI ON 2ND FLOOR EXECUTIVE OFFICE SUITES, CORRIDORS, OFFICES AND BREAK AREA. TOTAL AREA: 17,010 SQ.FT, NEW CONNECTED LOAD < 200A>>(B# 18016-10000-14443)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35924	10041-10000-21245	301 S ALVARADO ST	90057	1	135A205   243	5154030033	C2-1	Central	Westlake		YES	2088.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	11/28/2011 12:00:00 AM	ADDRESS	34.06264	-118.27319	24 KW PV SYSTEM. PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35925	12041-10000-18595	11038 W ARMINTA ST	91352	6	189B173   478	2314008040	QRD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.10, 1221.20	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	08/08/2012 12:00:00 AM		Permit Finaled	09/18/2012 12:00:00 AM	ADDRESS	34.21377	-118.37183	Remove and replace old Fire Alarm Control Panel with a new compatible one.  No new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35926	17041-10000-05940	1432 N TANAGER WAY	90069	4	147B169   722	5561024005	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.09747	-118.3856	PC FOR POWER ONLY FOR A SINGLE FAMILY DWELLING. SCOPE INCLUDES A NEW 800A 120V/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. B#16010-30000-01756	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35927	12041-10000-27581	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Tenant Improvement for new Retail withing existing space. 800 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35928	18041-30002-03552	355 S MUIRFIELD ROAD	90020	4	135B185   215	5505009007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.06741	-118.32894	03-29-2018 Changes to an approved set of plan. Changes include change AC4 MST/FLEX to 1 inch. All changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35929	15041-20000-34002	5514 N BONNER AVE 1-32	91601	2	174B173  1216	2350005045	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.17048	-118.37401	Fire alarm installation (109) devices on 32-unit apartement build.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35930	18041-20000-41727	9901 N LURLINE AVE BLDG 2	91311	12	201B109    59	2741002006	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Apartment			10/31/2018 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.25058	-118.58431	New meters, power, and lighting for converted dwelling units.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35931	13041-10001-31563	10414 N WHITEGATE AVE	91040	7	204B193   301	2559010029	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.25822	-118.30476	Expedited RSES plan check per applicant request.(((PV1, Install 3.75 kW DC roof-mounted solar array for 1 story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35932	12041-20000-00570	15303 W VENTURA BLVD #400	91403	5	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	34.15413	-118.46661	T.I. to existing high rise building on partial of 4th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35933	19041-20000-29907	2154 N WILLETTA AVE	90068	4	151-5A187 161	5576016029	RD2-1XL	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.11028	-118.3287	PV1 PLAN CHECK FOR INSTALLATION OF ADDITIONAL PV AND A NEW ESS TO EXISTING SFD. SYSTEM SIZE IS  7.667KW DC/7.04 KW AC. SCOPE OF WORK CONSISTS OF (11) PV MODULES AND (2) TESLA POWERWALLS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35934	16041-20000-22339	6435 W FIREBRAND ST	90045	11	102B165   417	4110022014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	33.97496	-118.40261	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.76 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35935	18041-20001-14626	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.08469	-118.4849	8/23/2018changes to an approved set of plans.  changes to add EM lighitng and update plans to reflect field conditions.This is plan check only.(((PLANCHECK FOR T24 ENERGY. TENANT IMPROVENT. REPLACING FLUORESCENT FIXTURES WITH LED. 1572 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35936	17041-20000-21259	500 W ALONDRA BLVD	90248	15	069B201   229	6120023033	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Apartment			06/23/2017 12:00:00 AM	10/11/2022 12:00:00 AM		Issued	10/11/2022 12:00:00 AM	PIN	33.88511079	-118.28309417	New 1200A 208Y/120V 3ph-4w service, distribution, power, and lighting for new construction.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35937	11041-10000-18988	8345 N GLENOAKS BLVD	91352	6	192B177   502	2404019046	C4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	09/07/2011 12:00:00 AM		Permit Finaled	10/12/2011 12:00:00 AM	ADDRESS	34.2226	-118.35968	replacement of propane dispensing system-includes 3hp pump motor and controls-all wiring are shown in classified and non-classified areas	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35938	13041-10000-05854	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.11883	-118.2495	PLAN CHECK FOR POWER AND ENERGY LAPD MAINTENANCE BUILDING. PARTIAL DEMO OF EXISTING BUILDING. POWER SUPPLIED FROM 2000A SERVICE LOCATED OUTSIDE, PLAN CHECK UNDER #13041-10000-05854. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35939	16041-10000-24224	8212 S BELFORD AVE	90045	11	099B169  1235	4105022036	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Expired	09/04/2018 12:00:00 AM	ADDRESS	33.96407	-118.38367	PV1. AN ADDITION TO AN EXISTING SOLAR SYSTEM. ADDING 3.0KWac TO AN EXISTING 3.8KWac PV SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS 6.8KWac.  (8)MODULES -KYCOCERA# KD255GX-FB3(8)OPTIMIZER-SOLAREDGE P300(1)INVERTER-SOLAREDGE #SE3000A-US-ZB-UROOFTOP SOLAR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35940	19041-20000-22197	22135 W ROSCOE BLVD LOT #21	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 21.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35941	14041-10000-01618	926 N SERRANO AVE	90029	13	144B193  1313	5535024028	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			Reviewed by Supervisor	01/28/2014 12:00:00 AM	ADDRESS	34.08704	-118.30626	PV1, Install 2.00 kW DC roof-mounted solar array for a two-story home, interconnect with existing panel.(1) Transformerless inverter: Power-One  AURORA  PVI-3.0-OUTD-S-US.(6) Modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35942	13041-10000-01014	9826 N COLUMBUS AVE	91343	7	201B145   289	2656006031	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.24905	-118.46503	PV1 9.36KW STD PLAN 1 STORY. 39 MOD ROOFMOUNT. sunnyboy 70000US. TSM-240 PC/PA05. has existing pv system as well.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35943	11041-20000-21973	1266 S LAKE ST	90006	1	129A201   183	5136024019	C2-1	Central	Westlake	Pico Union		2098.10, 2243.10	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.04752	-118.28378	PLAN CHECK T24 ENERGY FOR OFFICE TI. PERMIT FOR ELECTRICAL WORK, NEW LIGHTING, RECEPTACLES, AND SWITCHES ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35944	19041-30000-14800	1522 W LOMITA BLVD	90710	15	036B193    60	7410002085	[Q]R3-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Apartment			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	33.79764	-118.30346	Plan check for a fire alarm system for a 2-story, 14-unit apartment building. Fire alarm consists of (1) FACP and (57) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35945	15041-10000-08261	2993 N ALLESANDRO ST	90039	2	189B177   393	2466031026	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.10604	-118.24444	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACE EXISTING FIXTURES WITH LED LIGHTING.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35946	18041-20000-28705	4550 N VAN NUYS BLVD	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.15445	-118.4485	Change of use from retail to retail laundry mat.  Plan check for energy only.  Building permit under 18016-20000-24345.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35947	12041-10000-16701	4733 W SUNSET BLVD	90027	13	147B197   604	5543012018	C2-CSA1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM			PC Approved	07/18/2012 12:00:00 AM	ADDRESS	34.09833	-118.29305	PLAN CHECK T24 ENERGY FOR WORK STATION AREA IN KAISER MEDICAL OFFICE ROOM #B1146 ON FIRST FLOOR. SCOPE OF WORK NOT IN PATIENT CARE AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35948	15041-30001-37426	5880 W CENTINELA AVE	90045	11	102B169    61	4103005002	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	33.9764	-118.38423	06/23/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4. Changes have been made to the floor layout and new loads have been added.*****Previous Work Description*****FULL PC FOR HAZARDOUS LOCATION, TI IN AN AUTO DEALERSHIP GARAGE, SCOPE OF WORK INCLUDES  LIGHITNG AND RECEPTACLES ON THE AUTO GARAGE PORTION.  TOTAL SQ. FT. 9680.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35949	14041-10000-25897	403 S HIGHLAND AVE	90036	4	135B185   254	5507013001	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	34.06668	-118.33875	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL STANDARD PLAN. SYSTEM SIZE 6KW AC.(25) KYOCERA KD255(1) SOLAREDGE SE6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35950	16041-20000-45445	5015 N EAGLE ROCK BLVD	90041	14	162A221   218	5686021030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Closed	11/28/2023 12:00:00 AM	ADDRESS	34.13746	-118.21479	permit fee $0.00 state senate bill no. 1222pv2install roof mounted pv system sized 49kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35951	12041-20000-18665	20051 W VENTURA BLVD # H	91364	3	174B113   439	2166001031	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.17147	-118.57008	Veterinary clinic,. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35952	13041-20000-33167	4560 W FOUNTAIN AVE	90029	13	147B197  1103	5542020030	[Q]C4-2D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.09544	-118.28821	pc for t24 energy only. new lighting for new office partitions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35953	17041-30000-31235	501 W EL SEGUNDO BLVD	90248	15	081B201   259	6132002024	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	33.91659	-118.28337	Plan check for Title 24 only in existing space. replace new lighting. Total area: 1872 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35954	18041-10000-08356	8555 W COLGATE AVE 1-10	90048	5	138B173  1136	4334016030	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	11/27/2020 12:00:00 AM	ADDRESS	34.07093	-118.37799	PC for power and energy for 5 story 10 apartment unit building. Installing new 800A 120/240V service, panelboards, lighting, receptacles and equipment.Total area is 10415sqft. B#15010-10000-02873.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35955	17041-20000-17776	16852 W KNOLLWOOD DR	91344	12	216B137   534	2610016020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.28469	-118.49856	PV1.  Install 10 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35956	17041-10000-09194	9301 N TAMPA AVE 126A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A STORAGE SPACE FOR SUITE 126A. TOTAL AFFECTED AREA IS 728 SQ. FT. B#17016-40000-04411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35957	17041-20000-30482	19840 W NORDHOFF PL	91311	12	198B113   221	2761001067	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.23566	-118.56581	Plan check for a PV2 roof-mounted feed-in tariff PV project. System size is 200 kWac and consists of (3) inverters, (657) modules, and (1) load center.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35958	11041-20000-09960	3401 S GRAND AVE	90007	9	118-5A203  49	5122021011	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	05/23/2012 12:00:00 AM	ADDRESS	34.01998	-118.27645	PARKING STRUCTURE ENERGY PLAN CHECK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35959	14041-10000-08416	16550 W VENTURA BLVD 1F	91436	5	168B137   369	2284005025	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.15764	-118.4942	"permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A. 1st floor of 4 story building. emergency lighting. Restaurant: ""Whichwich"". fees under inspection.BLDG#14016 10 05945: REMODEL OF EXISTING 1200 SF BUILDING; NO SITE WORK; BUILDING EXTERIOR ENTRANCE DOOR RELOCATION; BUILDING INTERIOR NEW DINING AND KITCHEN EQUIPMENT; (N) EXTERIOR RAMP, CLOSE OFF ONE DOOR, REPLACE ONE DOOR WITH GLAZING; 2(N) AIR HANDLING SUPPORTS"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35960	13041-10000-22572	19800 W VINTAGE ST	91311	12	204B117   590	2726005008	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.25165	-118.56435	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN (GROUNDED). SYSTEM SIZE IS 8.085 KW DC AND 7.5 KW AC. [MODULES: TRINA SOLAR # TSM245PC/PA05 |||| INVERTER: FRONIUS # IG PLUS V 7.5]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35961	15041-20000-41427	16045 W FOOTHILL BLVD	91342	7	228B141   193	2603009041		North Valley				1065.10	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.32166	-118.48062	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,120 sq. ft.Note: Building permit has been pulled under application 14014-20000-04494	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35962	18041-10000-37768	10390 W SANTA MONICA BLVD	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Issued	10/18/2018 12:00:00 AM	ADDRESS	34.05734	-118.42365	NEW FIRE ALARM SYSTEM INSTALLED IN AN OFFICE COMMERICAL BUILDING. (1) FA PANEL, (217) FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35963	13041-10000-14606	217 E 8TH ST	90014	14	127-5A211 327	5145003005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.04155	-118.25168	Plan check power and energy for existing 12 story building with basment and roof deck. 77 units of joint living and work quarters.  New two 2000A service supplying building.  Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35964	19041-20000-48004	14611 W DRUMMOND ST	90272	11	126B129   247	4423025001	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.04373	-118.51777	PV1.  Install 12.40 kW roof mounted grid tied PV system.  (31) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35965	13041-20000-06291	2001 W JOHN S GIBSON BLVD	90731	15	024B201    45	7440016911	[Q]M3-1VL	Harbor	Port of Los Angeles	Northwest San Pedro	YES	9800.31	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Approved	03/11/2013 12:00:00 AM	ADDRESS	33.75887	-118.28777	Change to lighting, receptacles, circuits to an existing office space on the 2nd floor.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35966	15041-20000-10276	14828 W MORRISON ST	91403	4	169-5A149  58	2263029031	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.16021	-118.45617	Plan check for PV1 roof mounted  11.0kW system with 34 modules(SUNPOWER X21-335-BLK) and 2 inverters(SAM SB6000TL0UA-22 AND SAM SB5000TL-US-22)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35967	14041-20000-24800	7000 S HOOVER ST Unit #5	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #5.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35968	18041-20000-11579	6300 N CANOGA AVE Suite 1700	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.18492	-118.59722	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,632 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35969	17041-10001-16883	730 S SERRANO AVE 1-28	90005	10	132B193   438	5093014020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			02/12/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	06/06/2020 12:00:00 AM	ADDRESS	34.05884	-118.30642	PC for changes to approved set for addition of two new units, and change one new unit to two existing units,  and relocation of switchboard. All changes clouded. B#17016-20002-02430	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35970	16041-10000-05995	1751 E BAY ST	90021	14	123A215   239	5166035***	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Issued	04/25/2016 12:00:00 AM	ADDRESS	34.03159	-118.23577	$0 permit fee due to senate bill 1222 from 2012PV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 1060KW DC / 900KW AC. TOTAL OF 3366 MODULES IN TOTAL. 15 INVERTERS. CONNECTED TO EXISTING SERVICE. NET METER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35971	14041-10000-17715	225 1/2 N LARCHMONT BLVD	90004	4	138B189   581	5515018016	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.07538	-118.32384	PC for power and energy. Addition to an existing resturant. Total area 1542sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35972	16041-20001-28115	3611 N VERDUGO ROAD	90065	7			R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.11679	-118.23358	EXPEDITE PER APPLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MAP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35973	12041-20000-17209	15303 W VENTURA BLVD # 1080	91403	5	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	ADDRESS	34.15413	-118.46661	T-24 lighting plan check for suite 1080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35974	14041-10000-33458	12757 N DEON PL	91344	12	222B129   227	2608001012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.30265	-118.51387	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac. System consists of (2) inverters and (27) modules, distributed among 4 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35975	10041-10000-12832	2235 S MINER ST	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Public Safety Only			07/06/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	ADDRESS	33.72532	-118.27756	NEW CENTRAL MONITORING SYSTEM FOR TWO STATE APPROVED TRAILERS AT THE CABRILLO WAY MARINA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35976	14041-10000-31458	840 S ALVARADO ST	90057	1	130-5A203  42	5141020007	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Expired	12/07/2016 12:00:00 AM	ADDRESS	34.05355	-118.27845	Installation of new fire alarm system.  48 devices and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35977	12041-10000-19927	9948 N NATICK AVE	91345	7	201B149    42	2647011017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	01/03/2013 12:00:00 AM	ADDRESS	34.25141	-118.45297	This is one story, SFD, PV system , Transformerless INV.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35978	14041-10000-25052	3515 W SUNSET BLVD	90026	13	144A203   174	5429024002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.08926	-118.27643	Title 24 plan check only.  Total area = 1,433 sq. ft.T.I. to existing commercial space including  lighting and recepticles.Plan check only. Plan check and permit are pulled under 18041-10000-16921 & 18041-90000-37023Updated 07/22/2019	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35979	19041-20000-10791	1500 W 228TH ST	90501	15	045B193   414	7347017011	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.81885	-118.30384	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor and outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35980	16041-20001-29066	19850 W LINNET ST	91364	3	171B113    96	2164002013	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	PIN	34.1672967	-118.56561045	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system.Each module has a 300W power optimizer. (29) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35981	17041-20000-38656	3438 W GLENHURST AVE	90039	13	153A207    95	5437016017	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.11479	-118.2612	Plan check for solar pv system w/roof-mounted array on SFD.Total system size: 9.28kW ungrounded.(29) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35982	17041-10001-23954	759 N NORTH SPRING ST 1st Floor	90012	1	133-5A215  41	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM			PC Approved	07/21/2017 12:00:00 AM	ADDRESS	34.06146	-118.23727	This is plan check only for T24, permit was pulled online for the circuits under 17041-90000-23954.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35983	12041-10002-12908	3525-3535 E WHITTIER BLVD 1--78	90023	14	121-5A227 188	5188005021	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Apartment			05/27/2014 12:00:00 AM			PC Approved	05/27/2014 12:00:00 AM	ADDRESS	34.02645	-118.19754	Revisions to permitted set of plans; Types N1, N2,n3 AND n4 LUMINAIRES CHANGED TO led TYPES;NEW CKT ADDE TO PANEL GH1;revises Title 24 indoor sheets; added door to main electridcfal room ; panels GH21 and GH2 relocated further along the wall;lobby luminaires revised;corridors luminaires relocated-EM luminaires remained the same location. All changes are clouded on the plans.New 78-unit apartment complex with 2500A service.  Full plan check.  Variance will be filed to separate fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35984	18041-10000-23439	2735 S FIGUEROA ST	90007	9	121-5A203 142	5123015016	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.02634	-118.27738	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT TO AN EXISTING STARBUCKS (OCC LOAD = 61). TO INCLUDE REMODEL: DINING LAYOUT, PARTITION WALLS, LIGHTING FIXTURES, PLUMBING, MECHANICAL, ELECTRICAL, AND REPLACING PATIO FURNITURE. - TOTAL AFFECTED AREA = 2053 SF, CONNECTED LOAD <400A TO RE-USE EXISTING DISTRIBUTION SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35985	19041-20000-52779	1824 S 4TH AVE	90019	10	126B189   896	5072029016	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.20	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Closed	06/24/2022 12:00:00 AM	ADDRESS	34.04035	-118.32108	PV2.  Install 12.210 kW DC / 10.903 kW AC CEC roof mounted PV system.  (33) modules with microinverters.  3 separate interconnection points.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35986	19041-10000-10213	802 S FRIES AVE	90744	15	024B205    34	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	03/01/2024 12:00:00 AM	ADDRESS	33.76172	-118.26356	PC for power only. Replacement of a 4160V switchgear/service and replacing two unit substations with other associated ckts connecting to existing load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35987	14041-20000-29106	9526 N LAUREL CANYON BLVD	91331	7	198B161    63	2626013006	RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.24229	-118.41437	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(16) SUNPOWER E-20 327 MODULES(1) SUNNY BOY 5KW TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35988	15041-10000-29698	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	PC for power only to a commercial site (Westfield). Scope of work: remove 1600a switchbosrd and install 2 services wach to new 1600A switcgboard; SERVICE UPGRADE IS FOR FUTURE NEW LOADS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35989	16041-20000-27976	1835 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1-1, C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	34.04335	-118.37674	TI to (E) retail floor in (E) single story commercial building.  Plan check for energy.Note: permit is paid under PCIS#16041-30000-40782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35990	19041-10000-43335	5230 E ALHAMBRA AVE	90032	14	138A235    38	5217019020	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Issued	12/04/2019 12:00:00 AM	ADDRESS	34.07411	-118.17145	NEW ROOFTOP SOLAR SYSTEM CONSIT OF 58 MODULES (18 x SOLARBINE SB-S410SA1 and 40 x SHELLSOLAR SQ 150 PC), WITH TWO INVERTERS (1 x SUNNY BOY 5.0US AND 1 x FRONIUS PRIMO 5.0). SYSTEM SIZE 13.38KWdc AND 10KWac CONNECTED TO A NEW 225A SERVICE SERVICE UPGRADE TO BE PERMITTED SEPARATLEY	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
35991	15041-20000-06647	391 W CANYON VISTA DR	90065	1	147A223   104	5465010006	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.09786	-118.21196	Plan check for PV roof top mounted 4.5kW system with micro-inverter with 18 modules. Standard plan is NOT being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
35992	19041-20000-21497	13518 W KITTRIDGE ST	91401	2	180B157   493	2329008029	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/22/2019 12:00:00 AM	ADDRESS	34.1902	-118.42741	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM FOR EXISTING SFD WITH EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35993	16041-20001-22214	11328 W MAGNOLIA BLVD	91601	2	171B173   632	2353002041	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.16476	-118.37838	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 12. 4 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35994	15041-10004-36118	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	06/21/2017 12:00:00 AM	ADDRESS	34.24205	-118.59773	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED ON SINGLE LINE THE WAY THE WIRING WAS CONNECTED FROM COMBINER BOX TO INVERTER. NO OTHER CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35995	14041-10001-33003	2525 W WILSHIRE BLVD	90057	1	133-5A201  95	5141006017	C4-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM			PC Approved	12/13/2019 12:00:00 AM	ADDRESS	34.06059	-118.28114	"DELTA ""15"" Changes to approved plans for changing the size of ""Fire Pump"" from 75HP to 30HP installed at the same location using the same (Encased ) feeders. The new 30HP FP shall have the same performance as the 75HP FP and approved by the MPC subject to field inspection.  (((New 7-story  construction  for mixed-use development including 2 levels of subterrean parking garage , total 153 units and retails.  (2) new 3000A 120/208V services, power and lighting to residential and commercial areas.)))"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
35996	08041-10002-25990	505 S BONNIE BRAE ST	90057	1	133-5A205 270	5154026002	[T][Q]R4-1	Central	Westlake		YES	2089.03	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			No Progress	09/10/2010 12:00:00 AM	ADDRESS	34.05924	-118.27229	Modifications to previously approved set of plans for a new 53-unit apartment building, 6-story with one basement level.  The modifications are to the single line diagram and equipment as shown on the single line diagram.  See also elevation drawings and electrical room layout.  I.E. pages E1.0 and E4.1.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
35997	13041-10000-01203	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	AT THE DODGER'S STADIUM, REMODELING THE EXECUTIVE SUITES;PRESS BOX;AND GM SUITE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35998	11041-10000-04764	11666 W SHERMAN WAY	91605	6	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Public Safety Only			03/10/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Expired	05/16/2013 12:00:00 AM	ADDRESS	34.20103	-118.38536	NEW FIRE WARNING SYSTEM FOR THE KAISER MOB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
35999	18041-10001-18610	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			07/09/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	02/28/2021 12:00:00 AM	ADDRESS	34.06259	-118.35341	Changes to an approved set of plans, Changes include the addition of a fire pump and Jockey pump motor on the temporary installation, All changes noted on delta 2. ____________________PC FOR TEMP POWER FOR NEW PROPOSED 225 UNITS HIGH RISE RESIDNTIAL BUILDING. SCOPE INCLUDES NEW SERVICE 1600A 480/277V (IN METHANE ZONE) WITH HOIST CRANES AND PANELS.B#17010-10000-04785	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36000	15041-10000-26888	11518 W PICO BLVD	90064	11	123B153   492	4260034038	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.03314	-118.44243	PC FOR T-24 ON A EXISTING COMMERICAL BUILDING. PLAN CHECK FOR ENERGY ONLY. TOTAL AREA = 1842 SQ. FT. PLAN CHECK ONLY, FEES ARE PAID UNDER EXPRESS PERMIT #15041-30000-25831	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36001	15041-20000-32733	15535 W EL CAJON ST	91342	7	222B145   235	2604013020	RA-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.30365	-118.47042	PV1. Install roof mounted PV system sized 8.6 kW. Interconnected with main service panel.(38) Kyocera KU 265(1) ABB PVI 3.6 Inverter(1) ABB PVI-5000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36002	19041-20000-25142	8631 W ALLENWOOD ROAD pv1	90046	4	153B169    58	5565040017	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.11895	-118.38417	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36003	18041-20000-33652	1918 N HOBART BLVD	90027	4	150A195   121	5589004003	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.10597	-118.3059	pv1install roof mounted pv system sized 9.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36004	14041-20000-25936	15030 W VENTURA BLVD #10 B	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.15272	-118.46063	TI for (E) hair salon tenant space.  Plan check for 2013 Title 24 Part 6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36005	18041-10000-21712	13456 N GLENOAKS BLVD	91342	7	225B145    19	2502028001	RA-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.317	-118.4616	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36006	19041-10000-35065	7629 N DENSMORE AVE	91406	6	186B141    34	2206010010	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.20925	-118.47725	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36007	13041-10000-09362	400 S HOPE ST 26TH FL	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.05199	-118.25366	REMODELING EXISTING TENANT OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGECY CKTSPERMIT TO BE OBTAINED AT ELEC COUNTER AND PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36008	17041-20000-31204	801 S GRAND AVE Suite 200	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Issued	09/05/2017 12:00:00 AM	ADDRESS	34.04581	-118.25842	Plan check for Title 24 only. Project site is a suite in an existing high-rise commercial building. Project scope is a tenant improvement. Total lighting area = 408 sq. ft.Note: Building permit has been issued under 17016-10000-19308	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36009	18041-10001-07714	3016 S SOMERSET DR	90016	10	120B185   529	5050030040	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.02706	-118.33724	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36010	18041-10001-43634	10912 N PLAINVIEW AVE	91042	7	207B197   154	2552026003	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.26719	-118.29779	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36011	16041-20000-23165	210 N LADERA DR	90210	5	141B157    93	4358006046	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	04/10/2017 12:00:00 AM		Issued	04/10/2017 12:00:00 AM	ADDRESS	34.08184	-118.4235	Plan check for SFD(Single Family Residence) power only replace existing 600A main switch gear with a new switch gears(2) at 600A with associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36012	17041-20000-22677	9841 N AIRPORT BLVD 4TH	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTROOMS AND CORRIDORS ON 4TH FLOOR. HIGHRISE. 2251 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36013	10041-10000-17797	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	10/29/2010 12:00:00 AM	ADDRESS	34.05979	-118.41671	Ti in an existing restroom. Plan cheeck for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36014	14041-20000-17726	7320 N SHOSHONE AVE	91406	6	186B129  1070	2228003006	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.20366	-118.51654	PV1.  Install 6.75 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36015	13041-10001-27869	17527 W SEPTO ST	91325	12	201B129    11	2734019004	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.25138	-118.51671	EXPEDITED PER APPLICANTS REQUESTPV1. INSTALL ROOFMOUNTED SOLAR ARRAY. INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE:  16 kW. TRANSFORMERED  NEGATIVELY GROUNDED  SYSTEM.(64) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5(1) FRONIUS # IG PLUS V 5.0	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36016	19041-20000-03823	14200 W MULHOLLAND DR	90077	5	159B153   229	4379032011	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	06/29/2019 12:00:00 AM	ADDRESS	34.13029	-118.44235	addition of (2) tesla powerwalls(battery) 5KW each to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36017	17041-10000-46512	1118 N MCCADDEN PL	90038	4	144B185   681	5532021029	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.09129	-118.33733	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 585 FA DEVICES, AND 9 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36018	15041-20000-38234	560 W 1ST ST	90731	15	018B197  1095	7451007010	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	33.7434	-118.28915	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6 KW DC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36019	19041-20000-44146	1557 S ORANGE GROVE AVE	90019	10	129B173  1058	5068023008	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM	03/14/2022 12:00:00 AM		Issued	03/14/2022 12:00:00 AM	ADDRESS	34.04799	-118.36671	FULL PLAN CHECK FOR NEW SERVICE, DISTRIBUTION EQUIPMENT AND LOADS. NEW 1200A SERVICE. TOTAL SQUARE FOOTAGE = 29831 SF*******************************************Building work description under 19010-10000-04303	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36020	18041-10000-42753	4616 W DE LONGPRE AVE	90027	13	147B197   891	5542017033	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.0968	-118.29007	"FULL PLAN CHECK FOR MEDICAL FACILITY (CHILDREN'S HOSPITAL LOS ANGELES) - THIS PROJECT WILL CONSIST OF 6552 SF OF TENANT IMPROVEMENT WORK, INCLUDING EXAM ROOMS OF AN EXISTING 6-STORY, NON- OSHPD MEDICAL OFFICE BUILDING WITH TYPE ""B"" OCCUPANCY - TOTAL NEW CONNECTED LOAD APPROX = 100A ON EXISTING DISTRIBUTION SYSTEM."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36021	17041-10002-04608	20201 W RINALDI ST BLDG A2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Closed	02/12/2020 12:00:00 AM	ADDRESS	34.27512	-118.57373	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 25, 28, &10. CHANGES INCLUDE RELOCATING/ADDING SITE LIGHTING, REPLACING EXTERIOR LIGHTS, AND REVISING PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36022	11041-20000-13153	6500 W WILSHIRE BLVD 24th Floor	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM			PC Approved	06/24/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	Plan check T24 Energy (general/emergency) lighting on the 24th floor office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36023	15041-20000-19239	1989 W BLAKE AVE	90039	13	148-5A213 219	5442010017	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.1008	-118.24399	"Plan check for Title 24 only in existing office space. Total area: 8,876 SF""COMPLY WITH DEPARTMENT ORDER effective date 05/27/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36024	11041-10002-18978	5757 W WILSHIRE BLVD #360	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	01/19/2012 12:00:00 AM	ADDRESS	34.06259	-118.35341	PLAN CHECK POWER. REFEED PANEL A TO EXISTING 1600A SWITCHGEAR. TOTAL LOAD FOR 1600A SWITCHGEAR IS 900A. REMOVE TRANSFORMER AND FEED FROM HDP3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36025	19041-10001-47389	6425 N TYRONE AVE	91401	6	180B153   949	2237022023	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.1872	-118.44448	(expedite fees)PC for PV-2 system, 28KW system, 70 Modules with 400p optimizers and 3 7600H solaredge inverters. and 400 Amp service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36026	15041-10000-02463	8121 W MELROSE AVE	90046	5	141B173   388	5528007037	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.08387	-118.36666	Title 24 plan check only.  Total area = 958 sq. ft.T.I. to existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36027	15041-10000-32322	830 E WASHINGTON BLVD STE 7-8	90011	9	121-5A209 282	5131007027	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	01/26/2016 12:00:00 AM	PIN	34.02579758	-118.25410932	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING(OFFICE/FINANCIAL TRANSACTION AREA). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 1298 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36028	12041-10001-12412	10511 W TUXFORD ST PV1	91352	7	198B177   189	2544022021	RE40-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2012 12:00:00 AM			PC Approved	10/02/2012 12:00:00 AM	ADDRESS	34.23564	-118.35979	INSTALL ROOF MOUNTED SOLAR, INTERCONNECT W/ MAIN SERVICE PANEL. .  (6.45KW).  This submittal is plan check only.  Permit is existing under 12041-10000-12412	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36029	14041-20000-20585	7637 W MCGROARTY ST	91042	2	202-5A197  10	2558038019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.25139	-118.29932	PV1.  Install 7.596 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36030	19041-20000-17831	11727 W KIOWA AVE	90049	11	129B145   388	4265008042	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			05/13/2019 12:00:00 AM	12/09/2021 12:00:00 AM		Issued	12/09/2021 12:00:00 AM	ADDRESS	34.05061	-118.46342	Plan check for power and energy. Project site is a 5-story, 13-unit apartment building  over 2 levels of basement parking garage. Work includes an 800-amp service and a total lighting area of 21,557 sq. ft.Note: Building application has been generated under 19010-30000-01154	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36031	12041-20000-30323	12316 W COLLINS ST	91607	2	174B165   615	2340020012	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.17331	-118.40139	New 3.06kw enphase microinverter system for an existing single family residence.  Rooftop mounted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36032	14041-10001-13157	12125 W VENICE BLVD	90066	11	114B157  1334	4248030035	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM			PC Approved	11/19/2014 12:00:00 AM	ADDRESS	34.0054	-118.43084	LUMINAIRES HAVE BEEN CHANGED;PLAN CHK ONLY FOR REVISED TITLE 24Plan check for power and energy. place of assembly. Engineer lic#20701 not showing up. Fire alarm variance to be filed. *IEG submittal to be assigned to mehdi. BLDG#14016-30-05628: Interior remodel of existing bowling alley	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36033	13041-10000-33052	17046 W COTTER PL	91436	5	162B133    91	2292010029	A2-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/09/2013 12:00:00 AM	ADDRESS	34.14293	-118.50458	PV1 19.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. ?story. Roofmount. [(3) inverters: {SOLAREDGE SE6000A-US}]. [(78)modules: {Yingli {YL250-29b}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36034	15041-20001-11916	5695 S GOLDENEYE CT UNIT 2	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	33.97898	-118.41086	Expedite per applicant request********Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALLBE RELAVENT TO UNIT # 1 OF ADDRESS 5695 GOLDENEYE CORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36035	19041-10001-27422	8534 N HATILLO AVE	91306	3	192B113   122	2782018006	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.22551	-118.56499	NEW ROOF MOUNTED 12.24KW PV SYSTEM WITH 36 PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36036	19041-10002-12874	6801 W HOLLYWOOD BLVD C1-134	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.10229	-118.33907	Delta 3 changes to permitted set of plans: update MOCP and starters for FCU-3 and FCU-4; expand  electrical room into BOH corridor; update branch circuit ratings for FCU-3 and FCU-4 and revised spare capacity for panel HPLAN CHECK ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36037	10041-10000-25860	820 S OLIVE ST	90014	14	127-5A209  83	5144018028	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			Corrections Issued	02/24/2011 12:00:00 AM	ADDRESS	34.04452	-118.25719	NEW FIRE LIFE SAFETY STSTEM FOR A NEW 20 STORIES MIXED USE BUILDING. (EPC # 10041-10000-25858)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36038	14041-20001-03496	3928 N ENCINO HILLS PL	91436	5	162B133   125	2287015051	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.14163	-118.49982	(((changes to approved set of plans. reduced number of modules. permit now for 32 modules total. making new system size 6.9kw AC))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.2KW AC USING ENPHASE M215 MICROINVERTER. USING STANDARD PLAN.$0 fee due to senate bill 1222 from 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36039	14041-20000-07045	603 E VERNON AVE	90291	11	111B145  1694	4240013***	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			03/17/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	33.99705	-118.46989	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC. MAIN SERVICE PANEL IS RATED AT 400AMP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36040	14041-10001-33820	1150 N ORLON AVE	90272	11	132B125    51	4420007005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.05465	-118.53238	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 6.63 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(26) MODULES: YINGLY YL255P-29B(1) INVERTER: ABB PVI-6000-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36041	16041-10000-19086	1254 S WESTWOOD BLVD	90024	5	132B153   497	4325005022	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM			PC Info Complete	09/23/2016 12:00:00 AM	ADDRESS	34.05776	-118.44302	T-24, PC for energy only. Change of use from Retail to Massage Parlor. TI to an existing commercial building. Scope includes new lights and receptacles. Total affected area is 1045 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36042	14041-10000-25391	136 S VIRGIL AVE	90004	13	138A201   203	5501017045	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			09/16/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.0724	-118.28659	INSTALLATION OF A NEW FIRE ALARM SYSTEM. NEW FACP WITH 156 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36043	19041-10000-51925	13457 N NORRIS AVE	91342	7	225B145    97	2501024015	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.31634	-118.47206	[EPLAN] NEW PV1 INSTALLATION WITH A SYSTEM SIZE OF 9.24KW DC/ 8.96KW AC, WITH 28 MODULES (VBHN330SA16), 28 ENPHASE MICROINVERTERS (IQ7X-96-2-US), 1 COMBINER BOX AND NEW SERVICE PANEL RATED AT 225A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36044	15041-20001-41077	10457 N VARIEL AVE	91311	12	207B105   630	2706020021	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.26061	-118.59314	EXPEDITE PER APPLICANTPV1 roof mounted solar installation. 12kW AC (Panel derate)(40) SPR-327NE-WHT-D(2) PVI-6000-OUTD-S	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36045	17041-10001-44495	515 S FIGUEROA ST 1825	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	PC for T24 only for office TI. Installing new lights, receptacles and equipment. Total areais 4082sqft. Electrical permit fees where paid under 17041-90000-44495.B#17016-10000-29081.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36046	19041-10000-04527	326 N VIRGIL AVE	90004	13	139-5A201 101	5501003902	M1-1VL	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.07745	-118.28658	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36047	17041-10000-15233	22907 W OXNARD ST	91367	3	177B097   652	2039016025	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.17934	-118.62561	Rooftop solar isntallation PV1, 11.4 kW AC, 46 modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36048	13041-20000-00568	4726 N SAN SEBASTIAN DR PV-1	91364	3	168B097   661	2076009033	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.15411	-118.61935	PV-1. 8.16kW. Takac Residence. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36049	17041-20003-45762	14101 W PIERCE ST	91331	6	201B153   465	2644005032	RS-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.24748	-118.44057	10/4/2018department error in description of work.  no fee.(((Revisions to approved set. Removal of ESS from project scope.)))pv1roof mounted pv system sized 6.6KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36050	15041-20000-14247	11601 W WILSHIRE BLVD 1100	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	PIN	34.0509267	-118.45996763	Title 24 plan check only.  Total area = 7,250 sq. ft.  T.I. to existing commercial highrise office space.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36051	16041-20000-03260	7437 N RUFFNER AVE	91406	6	186B137   178	2226014015	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.20583	-118.49689	Plan check for PV roof mounted system. System size: 3.0kW with 11 modules and 1 inverter(3.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36052	18041-10000-25391	750 S LAMAR ST IWTP-SLUDGE CP	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	PLAN CHECH FOR POWER ONLY FOR UNION PACIFIC RAIL ROAD, SWITCHGEAR RATED AT 600A,  34.5KV, 3PH, 3W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36053	12041-10000-17717	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.14441	-118.39252	INSTALLATION OF 3 EA 400KW FUEL CELL SYSTEMS AND ASSOCIATED EQUIPMENT AT THE CBS STUDIOS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36054	15041-10000-40569	518 E COMMERCIAL ST Pump House	90012	14	130-5A215  71	5173002901	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.05288	-118.23427	One-story Pump House	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36055	18041-10000-26688	9870 N SAN FERNANDO ROAD #114	91331	7	201B165    56	2537015042	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.25001	-118.40419	PLAN CHECH FOR T24 ONLY FOR TI - CHANGE OF USE TO NURSERY. - TOTAL AFFECTED AREA = 2180 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36056	18041-10000-27713	2222 N FIGUEROA ST LOBBY	90065	1	142-5A219 493	5446016011	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.08296	-118.22327	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO THE LOBBY AREA . 332 SQFT.BUILDING PERMIT # 17014-10000-04212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36057	17041-20001-34932	213 1/2 S FRESNO ST	90063	14	124-5A227  58	5179005037	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.03691	-118.20021	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on 3-unit apartment building.3kW ungrounded system. (7) 300W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36058	12041-20000-14290	11614 W PICO BLVD	90064	11	123B153   669	4260033021	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.03217	-118.44413	T.I. to existing building (Lucca Salon).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36059	16041-10000-23013	1000 W ELYSIAN PARK AVE LV 7	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.07196	-118.24719	T-24, PLAN CHECK FOR ENERGY ONLY INDOOR AND OUTDOOR, SCOPE OF WORK INCLUDES NEW LIGHTING ON LV 7 IN THE DODGERS STADIUM.  INDOOR + OUTDOOR SQ. FT. 67,558	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36060	12041-20000-20015	910 W JEFFERSON BLVD	90089	9	120A201    20	5039003027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM			Corrections Issued	10/16/2012 12:00:00 AM	ADDRESS	34.024	-118.28511	Move 4.8KV loads between substation circuits to balance power distribution for USC campus.  Install new a manhole and expand some existing manholes.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36061	15041-20001-29377	21030 W GRESHAM ST	91304	3	195B105   139	2779003050	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Apartment			09/04/2015 12:00:00 AM			PC Approved	11/05/2015 12:00:00 AM	ADDRESS	34.23048	-118.59195	EXPEDITE FEESPLAN CHECKING FOR NEW DESIGN. PV2 COMMERCIAL ROOFTOP SOALR. PC 108 MODULES, 3 CENTRAL INVERTERS AND LOAD CENTERS. PV TO INTERCONNECT TO EXISTING SERVICE. NET METERED. TOTAL SYSTEM SIZE 27KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36062	15041-10000-23634	250 S ROSSMORE AVE	90004	4	135B185    14	5515013001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.06991	-118.32716	NEW FIRE ALARM SYSTEM 69 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36063	13041-20000-06139	20442 W RUSTON ROAD	91364	3	168A111   134	2174022014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.15298	-118.57903	New 8.82kw rooftop PV system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36064	15041-10000-41750	4810 S SAWTELLE BLVD	90230	11	111B165   303	4215029029	RD2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	33.99886	-118.40584	Power plan check for a 2-STORY 4-UNIT TOWNHOMES on top of a  garage above ground level.Scope include (1) 600-Amp service and six new Panels.BLD permit: 14010-10000-0030FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36065	13041-10001-05741	380 WORLD WAY space T71	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Delta 9 revisions to permitted set of plans-Changes are made in the kitchen to accomodate for kitchen design and relocate equipment((((((((((((PROPOSED 6,092 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (III FORKS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36066	18041-10000-02369	5890 W HOLLYWOOD BLVD	90028	13	148-5A191 186	5545004022	C2-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Issued	11/01/2018 12:00:00 AM	ADDRESS	34.10151	-118.31777	PC for power and energy for new car wash facilty. Installing new 600A 480/277V service, two new panels, new equipment and transformers, receptacles and lights.B#16010-10000-03882.:NEW EXPRESS CARWASH BUILDING PER  ZA-2015-3874	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36067	16041-20000-41648	4901 N AZUCENA DR	91364	3	168B101   388	2076006069	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Refund in Progress	08/22/2017 12:00:00 AM	ADDRESS	34.15715	-118.61473	PV1.  Install a 7.8 kW PV ground-mounted, grid-tied PV system.  (1) 7.6 kW inverter with power optimizers and (26) modules.Note: Building application has been generated under 16020-20000-04103.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36068	15041-20000-24859	10612 N ARLETA AVE	91345	7	207B149   532	2617009008	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.26322	-118.44819	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36069	19041-10001-38944	21255 W BURBANK BLVD SUITE 300	91367	3	174B105    87	2149019018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM			PC Approved	12/02/2019 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLAN CHECK FOR  ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS REVISIONS TO AN APPROVED FIRE ALARM SYSTEM, SCOPE OF WORK INCUDES ADDTIONAL DEVICES, CALCULATIONS HAVE BEEN UPDATED. NOTE ALL PERMIT FEES WILL BE UNDER 19041-10001-31975. NOTE THIS JOB WAS PREVISOULY SPLIT INTO THREE FLOORS. FIRST FLOOR IS UNDER 19041-10001-31975THE SECOND FLOOR IS UNDER  19041-10001-38943THE THIRD FLOOR IS UNDER 19041-10001-38944NOTE ALL CHANGES ARE CLOUDED UNDER DELTA 2. ---------ORGINAL WORK DESCRIPTION-----------THIS IS A PLAN CHECK ONLY FOR A TI TO AN EXISTING FIRE ALARM SYSTEM. SCOPE OF WORK IS ADDING DEVICES AND BATTERIES TO EXISITNG FIRE ALARM SYSTEM SPANNING THREE FLOORS. THIS IS THE THIRD FLOOR PORTION CONSISTING OF 134 DEVICES, AND TWO BATTERY. NOTE ALL FLOORS HAVE BEEN SEPARATED INTO THREE APPLICATIONS, ALL HAVE BEEN APPROVED BY FIRE. NOTE THE PERMIT FOR THE THIRD FLOOR HAS BEEN PULLED UNDER 19041-10000-38176	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36070	16041-10000-44935	3557 W CASITAS AVE LOT 4	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12088	-118.2571	Plan check for Power 11 buildings SFD live work  2 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 4 of 11Note: Master Application Lot 4 type B,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36071	19041-10000-28168	19340 W RINALDI ST	91326	12	210B117    25	2822019012	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Closed	12/02/2020 12:00:00 AM	ADDRESS	34.27348	-118.55489	POWER AND ENERGY PLAN CHECK FOR A TI-CHANGE OF USE FROM GROCERY STORE TO GROCERY STORE WITH TAKE OUT RESTAURANT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING RECEPTACLES AND CONTROLS. TOTAL CONNECTED LOAD IS MORE THAT 400A FED FROM AN EXISTING 2500A 120/208 3PH 4W SERVICE AND SWEITCHBOARD. TOTAL AFFECTED AREA 26734 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36072	19041-10001-39331	3868 N GLENALBYN DR	90065	1	145-5A223 340	5451012015	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.09166	-118.21338	Expedite per applicant requestPV1. NEW ROOFTOP SOLAR SYSTEM WITH BATTERY BACKUP. SYSTEM CONSIST OF 16 MODULES (FREEVOLT SW 300), OPTIMIZERS (PIKA ENERGY S2500), 1 CENTRAL INVERTER (PIKA X7602) WITH PIKA ENERGY HARBOR PLUS BATTERY. SYSTEM SIZE IS 4.8KWDC AND 8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36073	10041-20000-02908	11633 W SAN VICENTE BLVD #107	90049	11	132B145   475	4401019013	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	02/25/2010 12:00:00 AM		Permit Finaled	05/25/2010 12:00:00 AM	ADDRESS	34.05413	-118.46325	Medical office T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36074	14041-20000-20583	5116 N VARNA AVE	91423	4	171B157   763	2359002018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.16348	-118.42455	PVINSTALL ROOF MOUNTED PV SYSTEM SIZED 6.48KW IN TERCONNECTED WITH MSP.(27) SOLARWORLD SW275 MODULES(27) ENPHASE M250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36075	13041-20001-17020	6217 N CALVIN AVE	91335	3	177B117   357	2131018006	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	34.18306	-118.55574	((CHANGES TO APPROVESD SET OF PLANS. DIFFERENT WIRE SIZE. CHANGES CLOUDED)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.55 KW. USING 2 INVERTERS TRANSFORMERLESS. USING 30 MODULES. ROOF MOUNTED. USING POWER OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36076	17041-20000-39766	5307 N ALHAMA DR	91364	3	171B105   415	2167003028	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.16559	-118.59403	PV1.  Install roof mounted PV system sized 3.8kW interconnected with MSP.This is system (1) of a two part system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36077	19041-10000-41412	823 W 117TH ST	90044	15	084B197   196	6088010023	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	07/19/2023 12:00:00 AM	ADDRESS	33.92745	-118.2902	[E-PLAN] PV1. NEW ROOFTOP SOLAR SYSTEM WITH LG CHEM BATTERY BACKUP. SYTEM CONSIST OF 16 MODULES (SILFAB SLA Monocrystalline 320) WITH 16 OPTIMIZERS (SE P320 WITH 1 CENTRAL INVERTER (SE76000A-US). SYSTEM SIZE IS 5.12 KWdc AND 7.16KWacFees $91.17 Due to California Senate Bill 1222 and AB 1414PANEL UPGRADE TO BE PERMITTED SEPARATELY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36078	19041-10000-31560	7161 N SEPULVEDA BLVD	91405	6	183B145    82	2222029017	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.20086	-118.46648	TI IN AN EXISTING MCDONALD's RESTAURANT. REPLACING EXISTING LIGHTS IN THE MAIN DINNING AREA WITH LED LIGHTS AT THE SAME LOCATIONS CONNECTED TO EXISTING CIRCUITS. EMERGENCY LIGHTS ARE EXISTING TO REMAIN.  T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-35199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36079	14041-10001-02387	1417 S BURNSIDE AVE	90019	10	129B177  1116	5069032008	RD2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			Verifications in Progress	02/27/2014 12:00:00 AM	ADDRESS	34.04785	-118.35509	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 5.83 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel. (1)Transformerless inverter: POWER-ONE AURORA PVI-5000-OUTD-US(22) Modules: SUNIVA OPT265-60-4-1B0}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36080	18041-10000-32288	7057 N SHOUP AVE	91307	12	183B101   213	2024016105	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.19869	-118.61497	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36081	15041-10000-16313	12516 W OSPREY LANE #2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	33.97884	-118.41153	((((5/28/2015))))PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 2 SIZED 1.38KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19514	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36082	18041-20000-18506	977 N NORTH BROADWAY #210-213	90012	1	136-5A215 263	5414007022	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.06611	-118.23652	Plan check for Title 24 only. Project site is the the 2nd floor of an exising commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 9,718 sq. ft.Note: Building application has been generated under 18016-10000-15044	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36083	16041-10000-06318	11405 W CHANDLER BLVD 1-82	91601	2	171B173   101	2350011016	C4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.1682	-118.37935	New fire alarm system on a (N) 7-sory mixed use build. 2-story parking, and 82 residential units. (1) FA Panel, (1) Comm. (287) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36084	15041-20000-25801	6514 N LINDLEY AVE	91335	3	180B125   521	2123014027	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.18898	-118.52713	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (24) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36085	18041-10000-22687	248 S MAIN ST	90291	11	111B141   614	4286003020	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	33.99669	-118.47804	RENOVATE EXISTING SHOWER ROOM IN (E) OFFICE TO NEW SHOWER AND ALL GENDER RESTROOM. T-24 ENERGY ONLY. BLDG PERMIT # 18016-10000-19336	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36086	13041-10000-33044	12450 W TERRA BELLA ST	91331	7	210B165   528	2536021013	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.26843	-118.40378	PV1, Install 7.5 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (30) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36087	17041-10000-37916	545 S FRIES AVE	90744	15	027B205   619	7440009911	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM			PC Info Complete	10/25/2017 12:00:00 AM	ADDRESS	33.76483	-118.26423	T-24  ENERGY CALCS FOR NEW LIGHTS IN ROOMS #'S 110 - 114 ON THE FIRST AND SECOND  FLOORS. TOTAL AFFECTED AREA IS 2322 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36088	11041-20000-02420	6253 W HOLLYWOOD BLVD STE  205	90028	13	148-5A189 343	5546030035	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	09/09/2011 12:00:00 AM	ADDRESS	34.10179	-118.32624	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT TO (E) 2ND FLOOR OFFICE #205 IN EXISTING HIGH-RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36089	15041-20000-02623	4931 N LANKERSHIM BLVD #D	91601	2	168B173    66	2353017001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.16057	-118.37233	TI TO DANCE STUDIO. PC FOR T24 ENERGY ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36090	08041-10002-08721	5333 W ZOO DR Reptile-Center	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	1882.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.14867	-118.28623	Modification to previously appproved plans.  To be determined.  Wait for a list of changes made prior to plan review.  Center in the Los Angeles Zoo.Bond project: Prop. CC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36091	11041-10002-08519	8734 S BELLANCA AVE	90045	11	096B169   844	4125018007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	04/24/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	33.95765	-118.38038	"Changes to approved set under 11041-10002-08519. Changes are indicated by ""Delta 2"", ""Delta 3"" and are clouded. Addition of two motors and two branch circuits.  Motors are 30hp and 2hp. 2 new branch circuits for diverter valves."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36092	19041-10000-16796	8406 N NOBLE AVE	91343	6	192B145   317	2653025009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.22306	-118.46099	PV1, roof mounted system size is 11.4KWac. Scope of work includes three strings with 30 modules with optimizers (SUN2000-375W-USP0) , and a central inverter (SUN2000-11.4KTL-USL0). Note partial fees are charged under 19041-90000-13859	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36093	15041-20001-14385	11301 N YARMOUTH AVE	91344	12	210B129    43	2711017017	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	34.27582	-118.52112	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 8.815 kWac.  Microinverter system with 3 branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36094	15041-10002-37762	5715-5717 N FIGUEROA ST	90042	1	151-5A229 170	5492001015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.10994	-118.19246	REVISIONS TO PERMITTED SET OF PLANS-2 EA NEW PANELS AND CIRCUITS IN FUTURE TENANT SPACE; NEW LUINAIRES  ON EXISTING BRANCH CIRCUITS((((((((RENOVATION TO EXISTING BUILDING. NEW CORE AND SHELL WORK. NEW SERVICE AND HOUSE LOADS. NO TI AT THIS TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36095	12041-10001-23795	6047 N CARTWRIGHT AVE	91606	2	177B177   487	2414014003	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2013 12:00:00 AM			PC Info Complete	02/08/2013 12:00:00 AM	ADDRESS	34.18076	-118.36389	Changes to approved set 12041-10000-23795.  Changes limited to delta 2 only calling the correct breaker name and size in the load center.  Permit is existing .  this plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36096	13041-10000-14034	1840 S CENTURY PARK EAST STE105	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.06188	-118.41473	pc for energy only. TI TO EXISTING RESTAURANT. ADDING LIGHTS TO DINING AREA.suite 105 part of a hirise	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36097	17041-10000-14866	10635 W SANTA MONICA BLVD	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.05353	-118.43031	PC FOR ENERGY ONLY. T.I. EXCERCISE RMS FOR BLDG. TENANTS USE ONLY. CHANGE OF USE. TOTAL AREA 3426 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36098	13041-20000-15960	9300 N CORBIN AVE	91324	12	198B117   135	2761036029	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.23937	-118.56213	"Existing Dog ""Spa"".  Change to lighting and receptacles.  Load is less than 400 amps per applicant.   PLAN CHECK ONLY for Energy, with Emergency lighting."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36099	14041-20000-23464	10010 N CASABA AVE	91311	12	204B113   665	2741018022	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Expired	09/27/2016 12:00:00 AM	ADDRESS	34.25222	-118.57594	PV1 SFD. TOTAL SYSTEM SIZE 6 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING 29 MODULES.FIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36100	17041-10000-15556	5704 S 9TH AVE	90043	8	108B185   675	5006016026	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	33.99062	-118.32681	Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36101	10041-20001-22479	10821 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.26672	-118.52366	2 NEW PANELS TO REPLACE 2 SECTIONS PANEL LOAD IS THE SAME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36102	15041-10000-28813	4377 N TUJUNGA AVE	91604	2	165B173   430	2365015004	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.14959	-118.37914	PC for Energy only 423 sq.ft. **Permit issued and fees paid under 15041-10000-25402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36103	18041-10002-18540	21110 W OXNARD ST	91367	3	177B105    76	2149002023	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM			PC Info Complete	01/28/2020 12:00:00 AM	ADDRESS	34.17903	-118.59355	PC ONLY, CHANGES TO APPROVED SET. CHANGE INCLUDE COPPER TO ALUMINUM FEEDERS, ADDING/REMOVING EQUIPMENT AND REMOVING PANELBOARDS, ALL CHANGES HAVE BEEN CLOUDED UNDER DELTA #3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36104	14041-10001-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM			PC Approved	12/28/2015 12:00:00 AM	ADDRESS	34.0504	-118.26023	"This submittal is for expediting the the job, plan check only.  Permit is under master application 14041-10000-15237.Note:  nuumber of circuits used to calculate the expedite fee, circuits are covered under master application for permit purposes.>>>>>>PLANCHECK FOR POWER AND ENERGY. HIGH RISE CORE AND SHELL BUILDING INCLUDING 5 LEVEL PARKING GARAGE. "" WILSHIRE GRAND "" PROJECT. [[ FEES BASED ON APPLICANT; PLANCHECKER TO VERIFY]]<<<<<"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36105	12041-10000-20350	5755 W 96TH ST	90045	11	093B169   128	4125021024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	33.94955	-118.38214	ELECTRICALSERVICE  UPGRADES FOR  THE 1ST FLOOR PRODUCTION AREANOTE THAT # 12041-10000-20345 IS FOR THE TI WORK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36106	16041-20001-37318	5044 N BAKMAN AVE	91601	2	171B173  1066	2353013019	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			12/08/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.16205	-118.37722	[[ changes to approved fire alarm set. plancheck only.  removing  8 devices ]]]Installation of fire alarm system in new 5 story 46 unit apartment building.  Total system size = 160 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36107	16041-20000-02420	2145 E SACRAMENTO ST	90021	14	123A217   222	5166005008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.0307	-118.22836	TI to existing commercial building. Upgrade to 800A service. Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36108	11041-20000-06964	11400 W OLYMPIC BLVD #800	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.03666	-118.44346	T.I. to a high rise building.  Install general/emergency on 8th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36109	10041-20002-03362	20922 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM			PC Approved	05/27/2010 12:00:00 AM	ADDRESS	34.21974	-118.58937	PLAN CHECK ONLY T-24 ENERGY FOR NEW LIGHTING IN THE KITCHEN/FOOD PREP AREA OF EXISTING BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36110	15041-10000-09957	2530 S BROADWAY	90007	9	121-5A205 243	5126036008	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.02545	-118.26947	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHTING FIXTURES AND REPLACE WITH LEDS.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 14160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36111	17041-10000-11050	813 S FLOWER ST	90017	14	129A207   189	5144021031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	06/25/2021 12:00:00 AM	ADDRESS	34.04705	-118.26051	FULL PLAN CHECK FOR POWER AND ENERGY FOR (E) 12 STORY HOTEL.SCOPE OF WORK INCLUDES NEW 1200A SERVICE, AND ALL NEW DISTRIBUTION BOARD WITH ASSOCIATED EQIPMENT, INCLUDING BUT NOT LIMITED TO TRANSFORMERS, HVAC, POWER AND LIGHTING. TOTAL SQ. FT. = 22567(INDOOR = 18767, OUTDOOR = 3800:ESTIMATED)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36112	19041-20000-50310	6633 W EMMET TER	90068	4	150A185   151	5575009014	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.10631	-118.33445	PV1.  Install 7.03 kW DC / 6.53 kW AC roof mounted PV system.  (19) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36113	19041-20000-50362	21305 W LOPEZ ST	91364	3	171B105   956	2167006019	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.16227	-118.59499	Plan check for PV roof mounted system and Energy Storage System (ESS), PV system size: 12.395KW with 37 PV Modules and 2 inverters(7.6KW and 3.8KW), 1 LG Battery, 2 sub-panels	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36114	10041-10000-23781	12777 W JEFFERSON BLVD	90066	11	102B161  1158	4211009033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	06/20/2011 12:00:00 AM	ADDRESS	33.9778	-118.41768	ALTERATIONS IN OFFICE SPACES ON THE 1ST AND 2ND FLOORSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36115	17041-10000-12535	9301 N TAMPA AVE #135	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	11/24/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only in existing space T.I. restaurant Total area: 1526 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36116	12041-20000-02726	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM			PC Approved	02/28/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	Delta 3, 4 revisions to approved set of plan 11041-100000-18682, the contractor shall obtain a supplemental permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36117	15041-10000-27514	7198 W FORMOSA FUSION CT	90046	5	141B181  1708	5525003033	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08554	-118.34608	PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36118	17041-20000-35196	17319 W ROSCOE BLVD	91325	12	192B133   237	2787020030	P-1VL, QC2-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Closed	02/23/2018 12:00:00 AM	ADDRESS	34.22126	-118.51063	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM (E) 1400 SQFT RETAIL TO (N) KARATE STUDIO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36119	19041-10000-35077	843 N GALLOWAY ST	90272	11	126B129   160	4423028039	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM			Verifications in Progress	09/17/2019 12:00:00 AM	ADDRESS	34.04439	-118.52063	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10.2KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SOLIVIA 5.2 TL) WITH 36 MODULES HANWHA Q-CELLS SC315 USING RAPID SHUTDOWN DEVICE CONNETED TO EXISTING 200A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36120	19041-20000-41048	11881 W TERRA VISTA WAY #102	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36121	15041-10000-20015	5052 E YORK BLVD	90042	1	156A225   338	5477001011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Expired	07/20/2017 12:00:00 AM	ADDRESS	34.12101	-118.20516	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1139.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36122	19041-20000-25787	876 N ILIFF ST	90272	11	129B129   938	4423025016	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.04568	-118.51856	Plan check for a PV1 roof-mounted PV system. System size is 8.45 kWdc/7.584 kWac and consists of (26) modules, (26) micro-inverters, (2) load centers, and (2) battery back-up units.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36123	18041-20000-13458	11837 W MAYFIELD AVE	90049	11	129B145   510	4265015010	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			04/12/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.0499	-118.46609	New 26-unit 5-story apartment building with 1600A 120/240V 3ph-4w service.  Total area: 24370 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36124	16041-10000-22007	3215 W 76TH ST	90043	8	099B185    38	4012013023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	33.97101	-118.32924	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.945KWac.(23)MODULES-HYUNDAI HiS-S260RG(23)MICROINVERTERS-ENPHASE M215-60-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36125	12041-10001-27220	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	PIN	33.93847109	-118.41935625	RFI #99: CHANGES TO PERMITTED SET OF PLANSSEE ATTACHED SHEETS REGARDING THE CHANGESconstruction of Taxiway T and RON apron- power distribution system for aircraft power supply and airfield lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36126	18041-10000-24348	11244 W BRIARCLIFF LANE	91604	2	156B169   197	2381020019	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Expired	05/19/2024 12:00:00 AM	ADDRESS	34.12627	-118.38058	"""0$ permit fees due to senate bill 1222 ab1414""PLAN CHECH FOR ROOF MOUNTED PV SYSTEM FOR 65 MODULES WITH MICROINVERTERS(IQ7-60-US). SYSTEM SIZE = 15.6KVA"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36127	14041-20000-02724	6156 N SEPULVEDA BLVD	91411	6	177B145   387	2242025025	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.18225	-118.46593	PC FOR POWER SYSTEM LOCATED IN HAZARDOUS AREA. NEW FUEL ADDITIVE TANK FOR EXISTING GASOLINE STATION. PLAN CHECK FOR HAZARDOUS CLASSIFICATION AND POWER. ADDITIONAL PLAN CHECK TIME HAS BEEN ADDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36128	16041-10000-38366	3801 N BARHAM BLVD	90068	4	162B181    19	5581003***	[Q]C2-1-SN	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	Yes	1897.01	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Issued	11/29/2016 12:00:00 AM	ADDRESS	34.14381	-118.34135	Installatio of a new  fire alarm system for a 3-story commercial  building type B, with 586 devices and 10 fa panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36129	15041-20000-28603	613 E ROSE AVE	90291	11	111B141   200	4240003003	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	07/06/2017 12:00:00 AM		Issued	07/06/2017 12:00:00 AM	ADDRESS	33.99946	-118.47184	Plan check for power and energy. Adding 2 new services. Adding new panels. Adding new lighting including emergency. Total lighting area = 7,406 sq. ft. indoor and 1,124 sq. ft. outdoor.Building application description:PROPOSED 2-STORY MIXED USE W/BASE. GAR.,  CONSISTING  A DUPLEX @ 2ND FLR. W/3566 SF,   RESTAURANT 2392, & RETAIL  677 SF @ 1ST FLR.  (SHELL ONLY).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36130	13041-10000-05301	189 S THE GROVE DR Suite P	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.07125	-118.35662	T24 for cafe/kitchen addition in a Nordstrom department store.   4469 sq ft.  Total new connected load below 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36131	14041-20000-17276	5616 N FARRALONE AVE	91367	3	174B101   227	2146008255	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.17259	-118.61007	PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. CONNECTED TO 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36132	18041-20000-44684	714 N SWEETZER AVE	90069	5	141B173   374	5528003040	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	01/05/2021 12:00:00 AM	ADDRESS	34.08415	-118.37017	New fire alarm system for 5-story 26-unit apartment building.  FACP with 120 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36133	17041-10000-30987	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			Corrections Issued	09/02/2017 12:00:00 AM	ADDRESS	34.03396	-118.24117	TI FOR NEW BOXING GYM. PC FOR POWER AND ENERGY. OCCUPANT LOAD GREATER THAN 100.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36134	19041-20000-03754	19139 W STRATHERN ST pv1	91335	3	189B121   167	2104003027	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Issued	02/15/2019 12:00:00 AM	ADDRESS	34.21574	-118.55074	Plan check for a PV1 roof-mounted PV system. System size is 11.55 kWdc/9.82 kWac-CEC and consists of (1) 11.4 kWac-rated inverter and (35) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36135	15041-20001-43225	5716 N SUNNYSLOPE AVE	91401	2	174B157   327	2343014029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			PC Approved	01/02/2016 12:00:00 AM	ADDRESS	34.17446	-118.42674	Expedite FeePV1 rooftop solar installation(38) KU2656ZPA(1) SE10000A-US-ZB-U	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36136	13041-20001-33868	8445 N OAKDALE AVE	91306	3	192B113   295	2782010004	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.22341	-118.56682	((Expedite fees))PV1 TRANSFOMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. 24 MODULES AND 2 INVERTERS. SUBMITTED PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36137	17041-20001-08558	1965 N HILLHURST AVE Suite B	90027	4	150B197   560	5590012045	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.10719	-118.28759	Revisions to approved set of plans.  Change of lighting control system.  Approval is for delta-4 revisions on sheets E-200, 300, 400 only.  (((PLANCHECK FOR T24 ENERGY ONLY.  TENANT IMPROVEMENT  FOR CHANGE OF USE FROM OFFICE TO MASSAGE ESTABLISHMENT. 3557 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36138	15041-10000-33974	3308 E 3RD ST	90063	14	124-5A227 228	5179012031	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.03521	-118.19788	new roof mounted 7.6 KW solar PV array on existing single family dwelling.  Total systems ize = 7.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36139	13041-10000-21356	10585 W SANTA MONICA BLVD	90024	5	132B157  1074	4326033042	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Approved	08/12/2013 12:00:00 AM	PIN	34.05439965	-118.42928472	PLAN CHECK FOR TITLE 24 PART 6 ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36140	13041-10000-12348	3601 S TROUSDALE PKWY	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/13/2013 12:00:00 AM			PC Approved	05/13/2013 12:00:00 AM	ADDRESS	34.02017	-118.28558	permit to be pulled at EPC counter only. PC FOR ENERGY. SUBDIVID EXISTING SPACE. suite b1 in basement remodel. <400A per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36141	15041-10008-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	33.94286	-118.39982	11/03/2016 CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE 150KVA TRANSFORMER, 600A SWITCHBOARD, (2) 225A PANEL BOARDS. CHANGFES HAVE BEEN CLOUDED UNDER (DELTA 38 / ASI-200-200R1).NOTE : PACKAGE 6ADELTA 35 PLANS HAVE BEEN INCLUDED DELTA # 36 & 37 ARE STILL IN PLAN REVIEW.BRANCH CIRCUITS FOR NEW PANELS(2LL4 & 2LL5) SUMITTED UNDER APPLICATION (15041-10006-14585)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36142	13041-10000-01513	250 E 1ST ST	90012	14	130-5A213 150	5161016014	[Q]C2-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM			PC Approved	01/18/2013 12:00:00 AM	ADDRESS	34.05038	-118.24114	T24 OF OFFICE SPACE. EXISTING BUILDING. RELOACATION OF LIGHTING FIXTURES. TOTAL AREA 2996 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36143	13041-20000-22819	3966 S KEESHEN DR PV-1	90066	11	111B157   306	4235028016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.00251	-118.42697	PV-1. Power optimizers. 3kW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36144	11041-10002-08556	707 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM			PC Info Complete	03/18/2014 12:00:00 AM	ADDRESS	33.78001	-118.24199	2-14-14   Changes made to previously approved set, per mr. mike packerd pc needed.   ))                                                                                                                                                         8,997 SQ. FT. PRE-ENGINEERED METAL BUILDING.  1 STORY LOCOMOTIVE SERVICE AREA OVER 2 TRACKS, STORAGE ROOM, RESTROOMS, BREAK ROOM, OFFICE, SHOP, ELECTRICAL ROOM AND PARTS AND STORAGE ROOM.  FULL PLAN CHECK TO INCLUDE NEW PHOTO VOLTAIC SYSTEM AND  FIRE ALARM.  EVERYTHING IS NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36145	13041-20007-35598	11985 W BLUFF CREEK DR BLDG #3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	CHANGES TO APPROVED SET OF PLANS. RELOCATION OF LIGHTING CIRCUIT. PC FOR NEW AIC RATING OF VFD UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36146	13041-10000-13100	7227 N CIRRUS WAY	91307	3	183B093    76	2027010018	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	34.2011	-118.63688	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN. SYSTEM SIZE IS 10.78 KW. 44 MODULES IN FOUR STRINGS [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: FRONIUS # IG PLUS V 10.0]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36147	18041-10000-09087	901 N NICHOLSON AVE	90744	15	033B217   351	7429008025	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.78385	-118.22249	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36148	16041-10000-45275	201 N FIGUEROA ST 6TH FL-Suite 610	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	T.I. INTERIOR OFFICE REMODELING INCLUDING NEW FIXTURES AND RECEPTACLES. TOTAL SQ. FT. 6134	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36149	17041-20001-16715	10604 N LOUISE AVE	91344	12	207B133   736	2695005007	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			PC Approved	05/22/2017 12:00:00 AM	ADDRESS	34.26264	-118.51085	pv1expediteinstall roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36150	19041-10000-03649	6242 N SEPULVEDA BLVD	91411	6	177B145   204	2242010009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.18416	-118.46593	PV2, rooftop solar system on (E) motel. System size 17.6 kW AC / 16.59 kW DC STC / 14.79 kW AC CEC. Install (2) central inverters, (42) modules with (42) P400 optimizers, (1) 100A load center. System interconnect with 400A service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36151	15041-20001-41839	8830 N FARRALONE AVE	91304	12	195B101   158	2010006033	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM			PC Approved	01/08/2016 12:00:00 AM	ADDRESS	34.23112	-118.60953	01/08/2016 Changes to an approved set of plans. Changes have been made to the roof layout and the string configuration.*****Previous Work Description*****PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (25)MODULES-SW 285(25)OPTIMIZERS-P300(1) inverter SE 7600US-240VStandard plan is used	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36152	13041-10001-35235	3500 S SAN PEDRO ST PV2	90011	9	117A207   235	5121010008	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Expired	08/26/2016 12:00:00 AM	ADDRESS	34.01445	-118.26565	[[[[7/25/14 CHANGES TO APPROVED SET OF PLANS, DELTA 2 AND 3 CHANGES ONLY. CHANGING THE MODULES AND ADDING A 200 AMP SUBPANEL]]]]]]PV2, ROOF-MOUNTED SOLAR PV INSTALLATION IN (E) WAREHOUSE, INTERCONNECTING TO (E) 240/120, 400A 1PH 3W MAIN SWITCH GEAR. SYSTEM SIZE IS 23.7W kW DC. 20.39kW AC WITH 8 TOTAL STRINGS. SYSTEM IS TRANSFORMERED, WITH THE FOLLOWING EQUIPMENT TO BE USED:(3) INVERTERS: SMA SB 8000US, SB 6000US, SB 7000US(1) 200A SOLAR SUBPANEL(93) MODULES: EAT PHONO SOLAR, SW255MONONOTE: PLANS NON-EXPEDITED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36153	16041-10000-17431	1925 S CENTURY PARK EAST ste. 600	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI  TO AN EXISTING OFFICE BUILDING  SUITE 600 (6TH FLOOR). USING EXSITING CIRCUITS TOTAL  AREA 7819 SQFT. ENERGY ONLY.INSTALL LOW VOLTAGE FOR DATA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36154	14041-20001-10779	13361 N GLADSTONE AVE	91342	7	225B153   251	2509001007	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.31435	-118.43309	Roof mounted PV system with Optimizer, system size 6.25KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36155	17041-20000-12363	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.18686	-118.37207	ti to an existing commercial building.  Adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 21433	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36156	18041-10001-41854	341 N VAN NESS AVE	90004	4	138B189   219	5522027018	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			PC Approved	11/16/2018 12:00:00 AM	ADDRESS	34.07738	-118.31586	SUPPLEMENTAL FOR EXPEDITE FEENEW SFD ROOFTOP PV SYSTEM 12.285 DC KW ARRAY, (1) 11.4 AC KW INVERTER, (39) 315W MODULES WITH P400 POWER OPTIMIZER, CONNECTED TO A 225A MAIN SERVICE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36157	15041-10000-07364	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	PIN	34.0586034	-118.41904766	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1422.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36158	14041-10001-15013	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM			PC Approved	07/24/2015 12:00:00 AM	ADDRESS	34.01118	-118.33649	Revisions to approved set.  Additional lighting fixtures to accommodate revised show window layout. (((TITLE 24 PLAN CHECK ONLY TOTAL AREA = 5079 SQ FT.REMODELING A RETAIL TO NEW RETAIL IN MALL)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36159	10041-20000-14222	3647 N CARIBETH DR	91436	5	162B137   544	2286002036	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.13756	-118.48902	Plan check for installation 10.33KW Photovoltaic System for residential single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36160	14041-10000-23709	6532 N RADFORD AVE	91606	2	180B169   724	2322020050	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Expired	10/03/2016 12:00:00 AM	ADDRESS	34.18957	-118.39201	Standard PV1 Plan, 4.25KW roof-mounted system including one Solaredge SE3800A inverter,( 17) Kyocera KD250 modules and Solaredge P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36161	19041-10001-14665	8843 N DORRINGTON AVE	91331	6	195B157   668	2640024028	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	34.23037	-118.43139	SUPPLEMENTAL CHANGES TO APPROVED SET INSTALLING COMMERCIAL SAFETY SOCKET SERVICE METER. <<<PV1, ROOF MOUNTED SOLAR SYSTEM USING AC MODULES INTERCONNECTED TO A LOAD CENTER. (20) AC MODULES TOTAL SYSTEM SIZE IS 7.2KWDC AND 6.4 KWAC.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36162	15041-10000-06482	1648 N KINGSLEY DR	90027	13	148-5A195 129	5544015010	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			Verifications in Progress	07/01/2015 12:00:00 AM	ADDRESS	34.10129	-118.30303	PV2, INSTALL NEW 17.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING. (70) MODULES; (3) INVERTERS: DELTA -SOLIVIA 5.2TL(2)AND 7.6TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36163	14041-20001-14167	13976 W POLK ST	91342	7	228B153   636	2504021037	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.31794	-118.43788	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 9kW(1) Power-One  # Aurora PVI-6000-OUTD-US-Z-A transformerless inverter(1) Power-One  # Aurora PVI-3.0-OUTD-S-US-Z-A transformerless inverter(41) Canadian Solar #CS6P-250PX pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36164	13041-10000-26542	8055 W 3RD ST	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.07218	-118.36515	(applicant brought in revised sheets 10/16/2013 - fees to be added for new changes.)PC FOR POWER ONLY. (E) BLDG CHANGE 1P3W TO NEW 3P4W SERVICE + house panel (200A) and 5 tenant panels (1x 400A and 4x 200A).  No current tenants - modification of a currently shell building for future TI. METHANE ZONE.SUBDIVIDE EXISTING BUILDING FROM THREE TENANT SPACES INTO 5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36165	17041-20000-34465	507 3/4 E BOCCACCIO AVE	90291	11	108B149  1622	4237007013	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	33.98841	-118.45857	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,644 sq. ft.Note: Building permit has been issued under 17016-30000-09405	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36166	19041-20000-53335	19540 W LANARK ST	91335	3	189B117    91	2105003009	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Issued	12/26/2019 12:00:00 AM	ADDRESS	34.21779	-118.55955	Plan check for PV roof mounted system, PV system size: 11.34KW DC, 10.34KW AC CEC with 36 PV Modules and 1 inverter(10KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36167	10041-10003-03624	6724 W HOLLYWOOD BLVD B-1	90028	13	148-5A185 146	5547012018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.10139	-118.33715	(((DELTA 8 CHANGES))) (Peter) Modifications to previously approved plnas for a T.I. for 8-story high rise building Church of Scientology.  Plan check for power and energy. New electrical system with 1600A service. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36168	19041-20000-08619	12325 N FINCH ST	90039	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	PIN	34.3012906	-118.58563914	(N) 2-STORY SFD W/ ATTACHED GARAGE LA CITY STD PLAN #649, UNIT PLAN #3CR (NFPA-13D FIRE SPRINKLERS THROUGHOUT)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36169	16041-10001-08351	524 E WASHINGTON BLVD	90011	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	PIN	34.02811119	-118.25991573	EXPEDITE PER APPLICANT REQUEST. ((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS(1294) MODULES-ECOSOLARGY ECO310H156P-72 (11)INVERTERS-SOLAREDGE SE33.3K(647)OPTIMIZERS-SOLAREDGE P700	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36170	15041-10000-02304	3456 S MOTOR AVE # 102	90034	5	120B161   364	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.02698	-118.40853	TENANT IMPROVEMENT FOR EXISTING RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36171	18041-10001-45235	2003 N EDGEMONT ST	90027	4	150B197   493	5589015006	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.10792	-118.29643	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36172	13041-20000-25341	11055 W CUMPSTON ST	91601	2	174B173  1242	2350003009	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			09/13/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.17012	-118.37213	NEW FIRE ALARM SYSTEM FOR APARTMENT BUILDING. 116 DEVICE AND 1 FIRE ALARM CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36173	15041-20000-40865	822 S LA BREA AVE SPACE 9	90036	4	132B181   315	5084003047	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.05991	-118.34469	TI for (E) retail space.  666 sq. ft  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36174	18041-10000-43634	10912 N PLAINVIEW AVE	91042	7	207B197   154	2552026003	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.26719	-118.29779	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 35 MODULES (PANASONIC N330) , 35 OPTIMIZER (SE P400) AND A CENTRAL INVERTER (SE10000H-US).  SYSTEM SIZE IS 11.55KWdc and 10KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36175	14041-10000-27758	479 S HOLT AVE	90048	5	135B173    94	4334020014	R1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.06996	-118.3786	PV1 ROOF MOUNTED SYSTEM INCLUDING  (20) Enphase M250 microinverters, and (20) LG 300 mono modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36176	18041-20000-47334	13036 W CHANDLER BLVD	91401	4	171B161    99	2345020018	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.1682	-118.41709	PV1.  Install 11.47 kW roof mounted grid tied PV system.  (37) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36177	18041-10000-46749	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	33.97615	-118.42138	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES INSTALLATION OF A NEW 250KW GENERATOR  AND 1200 AMP ATS PANEL. NO NEW LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36178	13041-10000-22483	19500 W PLUMMER ST UNIT B2	91324	12	198B117    88	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			PC Info Complete	09/19/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING. T.I. OF EXISTING RESTAURANT SPACE. SCOPE OF WORK IS LESS THAN 400 A. SINGLE STORY BUILDING SPACE B2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36179	17041-30000-15318	1317 N DELRESTO DR	90210	5	144B157   116	4356014021	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM			PC Info Complete	06/09/2017 12:00:00 AM	ADDRESS	34.09365	-118.42585	Plan check for power only. Project site is an existing single-family dwelling. Project scope is a major addition and remodel with a new electrical distribution system.Note: Building permit has been pulled under 14014-30000-03699	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36180	19041-10000-02898	555 S FLOWER ST SUITE 4400	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI IN EXISTING OFFICE SPACE IN SUITE# 4400. TOTAL AREA: 4378 SF. INSTALLING NEW LIGHTS. T-24 ENERGY. BUILDING PERMIT: 19016-10000-01794	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36181	16041-20000-15643	6171 N VALLEY CIRCLE BLVD	91367	3	177B089   850	2032011073	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Expired	06/06/2018 12:00:00 AM	ADDRESS	34.18354	-118.65627	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36182	12041-20000-19219	5610 W PARK OAK PL	90068	4	153B193    64	5580029008	RE15-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.11682	-118.31162	pv system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36183	15041-20000-11157	16901 W NAPA ST	91343	12	195B133   508	2689018032	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Apartment			04/14/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.22679	-118.50046	Plan check for PV 22.8 kWac system roof mouned with 2 inverter (CANADIAN SOLAR CS6X-305SSP), 88 modules (canadian solar cs6x-305sp) and 2 combiner boxes.Note: Permit fee is $0.00 due to Senate Bill 1222.Note: Zoning clearance shall also apply to the PV2 system under application 15041-20000-11505	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36184	13041-10000-06536	3930 N VALLEY MEADOW ROAD	91436	5	162B141    94	2286017019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Issued	06/17/2013 12:00:00 AM	ADDRESS	34.14213	-118.47889	Upgrade service from 400A to 800A  and installing 100 KW stand by generator for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36185	17041-20000-16840	11710 W BARRINGTON CT	90049	11	135B145   646	4401007018	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.06417	-118.46952	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36186	17041-10001-07541	20929 W VENTURA BLVD Building A	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	"[[7/31/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. ADDITION OF 800AMP  AND 200AMP BREAKER AND FEEDER FOR FUTURE PANELS TO THE ""MSA"" MAIN SWITCHBOARD ]]]]Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 1200-amps.Note: Building application has been generated under 16016-20000-22112"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36187	17041-20001-10398	14757 W KESWICK ST	91405	6	189B149   596	2210025019	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.21046	-118.45497	12.12.2017 - Plan check for modifications to approved set. Reduce the feeder breaker sizes for panel E and F to 150A, and panel B to 80A. Only changes - clouded delta 1.======PC FOR 800A SERVICE UPGRADE TO COMMERCIAL SPACES. PROVIDING NEW SERVICE AND PANELS. REFEED EXISTING CIRCUITRY. THIS IS PC FOR POWER UPGRADES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36188	18041-20000-45333	143 S WETHERLY DR	90048	5	138B169   486	4335008015	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			11/29/2018 12:00:00 AM	07/15/2021 12:00:00 AM		Permit Finaled	06/28/2023 12:00:00 AM	ADDRESS	34.07407	-118.38904	New 40-unit 5-story apartment building.  1600A 208Y/120V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36189	12041-10000-00038	1800 S CENTURY PARK EAST 14th Floor	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.06244	-118.41523	Plan check T24 Energy/Emergency lighting for tenant improvements on the 14th floor. Permit for lighting, exit signs, and receptacles on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36190	15041-20000-08838	10710 W CHALON ROAD	90077	5	141B149   147	4362003036	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2015 12:00:00 AM			PC Info Complete	04/03/2015 12:00:00 AM	ADDRESS	34.08283	-118.44927	Plan check for power for a new single family home. Project scope includes the installation of a new 600 amp service, (2) 600-amp rated main switchboard, (9) subpanels and associated loads, (1) 50 kWac generator, and (1) 5HP elevator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36191	14041-20001-06016	510 S NORMANDIE AVE 1-40	90020	10	135B197   812	5502018022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			03/05/2014 12:00:00 AM			Reviewed by Supervisor	03/18/2014 12:00:00 AM	ADDRESS	34.06494	-118.30016	(((EXPEDITE FEES)))PV2 ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMED INVERTERS. TOTAL SYSTEM SIZE 23KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36192	19041-10001-25857	10250 W SANTA MONICA BLVD 2720	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Approved	11/13/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Delta ""1"" & Delta ""2"" changes to aproved plans.  Replacing 4 @ 1Amp Current Limiter CB's with 1 @ 4Amp CL.(((Energy pc only for T.I. to existing virtual reality entertaininment space in POD #4. area of scope is 827sf.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36193	15041-10000-19452	2029 S CENTURY PARK EAST ste 2550	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24 TO AN (E) HIGH RISE OFFICE BUILDING. SCOPE OF WORK IS ON THE 25TH FLOOR. ADDING NEW LED LIGHTING. PC FOR ENERGY ONLY. TOTAL SQ. FT. 7655.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36194	18041-20001-47177	4536 E BEND DR	90065	1	153A221   386	5475018026	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.11216	-118.22032	Plan revision to update meter spot location of (N) MSP.  $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414. (((Plan check for a PV1 roof-mounted PV system. System size is 5.76 kWdc/5.12 kWac and consists of (16) AC PV modules and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36195	16041-30000-09097	6445 N WOODLEY AVE 1-4	91406	6	180B141   771	2233026020	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	Apartment			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.18806	-118.48397	Installation of fire alarm system in new 2 story 5 unit apartment building.  Total system size = 3 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36196	12041-10000-16503	1652 W 204TH ST #10 & 11	90501	15	054B193   719	7351006033	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Apartment			07/25/2012 12:00:00 AM			Reviewed by Supervisor	08/24/2012 12:00:00 AM	ADDRESS	33.8455	-118.3085	CONVERTING STORAGE & COMMUNITY ROOMS TO RENTALS, NEW 600A SERVICE AND NEW MAIN SERVICE PANEL.  NO NEW SUBPANELS AND NO NEW CIRCUITS AND NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36197	11041-10000-14251	2200 W SUNSET BLVD	90026	13	139-5A207  76	5402029022	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.07784	-118.26623	T.I.  Existing 7-11.  Replacing the florescent lights with LED lights on the retail floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36198	18041-20000-42069	1999 S AVENUE OF THE STARS 3rd flr	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	ti to an existing commwercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36199	11041-10001-13875	639 W 28TH ST	90007	9	121-5A203 102	5123015403	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM			PC Approved	07/07/2011 12:00:00 AM	ADDRESS	34.02677	-118.27859	Kitchen Remodel FOR A SORORITY HOUSE.  PLAN CHECK IS FOR T-24, ENERGY ONLY.  PLAN CHECK ONLY, PERMIT WAS PREVIOUSLY PULLED ON A SEPERATE APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36200	16041-30001-17653	5325 E BALTIMORE ST	90042	1	154-5A227 220	5478009041	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.11754	-118.20032	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (13) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36201	14041-20001-05226	5824 S WEST SEAGLASS CIR	90094	11	102B157   400	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97371	-118.41951	((EXPEDITE FEES)PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36202	17041-10000-11253	660 S FIGUEROA ST #2250	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR ENERGY. T.I. CONNECTED LOAD< 400A, TOTAL AREA 3882 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36203	17041-20000-33990	11601 W WILSHIRE BLVD 1660	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for energy only. TI to office suite 1660 in high rise building. New lighting (incl. emergency) - 1,277sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36204	19041-20000-25551	136 S LA BREA AVE	90036	5	138B181  1015	5513018009	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.07244	-118.34383	Plan check for Title 24 only in existing space Tenant Improvement retail. Total area: 2648 sq ft. B#19016-20000-20255	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36205	19041-20000-42417	6400 N LAUREL CANYON BLVD 230	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.18693	-118.3963	Tenant improvement add new lights P.C for title-24. Total area: 1525 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36206	16041-10000-17677	12027 W CLARKSON ROAD	90064	11	120B153  1133	4257016058	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.02187	-118.44262	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.095KWdc / 3.12KWac.(13)MODULES-LG315N1C-G40(13)MICROINVERTERS-ENPHASE M250-60-LL-2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36207	14041-20000-28670	8976 N LAUREL CANYON BLVD	91352	6	195B165   167	2629019021	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM			PC Approved	10/29/2014 12:00:00 AM	ADDRESS	34.23276	-118.40423	PV2 COMMERCIAL ROOFTOP SOLAR. NEW SYSTEM DESIGN. THIS IS NOW AN 8KW SYSTEM. USING 32 MODULES. SINGLE INVERTER TRANSFORMER TYPE. 2 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36208	15041-20001-00893	5155 N BASCULE AVE	91364	3	171B109   186	2166028023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.16436	-118.58664	Expedite per customer request.PV1. Install roof mounted PV system sized 11.76 kW. Interconnected with main service pannel.(49) MonoX LG300N1C Modules(49) Enphase M250 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36209	16041-10001-06720	251 WORLD WAY CELL SITE	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			Corrections Issued	06/16/2016 12:00:00 AM	ADDRESS	33.94463	-118.40431	06/16/16PC FOR POWER ONLY FOR A T-MOBILE PARKing STRUCTURE ON THE 3RD FLOOR EQUIPMENT ROOM. SCOPE INCLUDES A NEW 200A PANEL. PC PER APPLICANT REQUEST. NOTE: PERMIT  IS PULLED UNDER PCIS#16041-10000-06720(((((NEW 2 POLE 100 AMP BREAKERS/ 4 X 60AMPS 1 X 20AMPS 1 X 15 AMPS NEW 200 AMPS PANEL NEW SUBMETER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36210	14041-20000-10655	12676 N NORRIS AVE	91342	7	219B149    62	2507002024	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	34.30068	-118.45016	PV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL TRANSFORMERLESS INVERTER STANDARD PLAN. SYSTEM SIZE: 2.25 KW DC.(9) CANADIAN SOLAR CSP 250(1) POWER ONE  PVI 3.0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36211	19041-20000-37301	14738 W OXNARD ST	91411	4	177A149   179	2244009034	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.17918	-118.45434	T24 PLAN CHECK FOR TI REMODEL OF EXISTING COMMERCIAL BUILDING RESTROOMSAND OUTDOOR LIGHTING. INDOOR AND OUTDOOR LIGHTS. NEW LIGHTS, OUTLETS, PANELS, AND EQUIPMENT. TOTAL SQUARE FOOTAGE = 2089 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36212	12041-20000-09034	8401 N VAN NUYS BLVD	91402	7	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	01/02/2013 12:00:00 AM	ADDRESS	34.22308	-118.44896	energy plan check cove lighting only mall arena emergency lighting existing to remain.  ((PERMIT FEES ARE UNDER INSPECTION).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36213	19041-20000-07510	13733 W WYANDOTTE ST	91405	2	186B153   638	2216036010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.20318	-118.43255	Plan check for a PV1 roof-mounted PV system for existing sfd. System size is 4.8 KW DC/7.6 KW AC and consists of (1) 7.6 kWac-rated inverter, (15) silfab solar pv modules with SE P320 optimizers, (1) 5 kw auto transformer, (1) 5kw battery back-up unit LG Chem, and (1) 125A load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36214	15041-20000-42735	615 W CHILDS WAY	90089	9	118-5A201  27	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.0191	-118.28214	Plan check for power (medium-voltage) and energy. Project site is an existing commercial building (residence halls for USC). Project scope is the replacement of electrical service equipment and lighting within the electrical rooms. Work includes the installation of a new medium-voltage substation, (5) switchboards, (3) trasformers, (2) panels, and associated loads. Total lighting area = 409 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36215	16041-10000-21622	13681 W FOOTHILL BLVD	91342	7	222B157    46	2509015027	(T)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.30865	-118.4315	PC for energy only. First time tenant to fast food restaurant (Panda Express). Existing service, (2) new panels. Newly connected load is less than 400 amps. Total Sqft = 1956	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36216	17041-20001-06071	4212 N COLDWATER CANYON AVE	91604	2	165B161   999	2375021020	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM	ADDRESS	34.14561	-118.41355	"10-11-2019 Changes to an approved set of plan changes include lighting layout changes. All changes apply to delta ""A "" only. Plan check only, permit covered under master application."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36217	15041-20002-16517	16515 W BALLINGER ST	91343	12	201B137   947	2677005004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.24394	-118.49185	03/03/2016 Plan check for a lost set of PV plans.*****Previous Work Description*****Changes to an approved set of plans. Changes are only to the PV module layout.*****Previous Work Description*****pv1 sfd. total system size 3.2kw ac using microinverter system. using enphase m215. nonstandard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36218	19041-10000-06631	17428 W KESWICK ST	91325	12	186B129    57	2202007006	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.21008	-118.5129	Plan check for a 5kW AC / 4.88kW DC roofmounted system with (1) inverter, (16) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36219	16041-30000-00272	15150 W ROXFORD ST 1-45	91342	7	228B145   441	2502004038	C2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Apartment			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.31841	-118.46333	Installation of fire alarm system in new 33 unit 4 story apartment building.  Total system size = 109 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36220	13041-20000-30564	920 W DOWNEY WAY LAB B-2	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.02063	-118.28879	T24 FOR EXISTING LAB ROOM FOR USC. Basement B-2. USC BHE Lab B2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36221	17041-20000-12719	2700 W COLORADO BLVD unit 144	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.14248	-118.22438	ti to an existing commercial single story building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 154.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36222	18041-20000-24335	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Replacement of temporary distribution equipment with permanently installed equipment (medium and low voltage).  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36223	10041-10000-19258	380 W WORLD WAY TBT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	12/07/2010 12:00:00 AM	PIN	33.94094587	-118.40577128	REPLACEMENT OF 4 ESCALATORSAT TBT TERMINAL AT LAWA. SUBMITTORS INSISTS FOR PLAN CHK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36224	15041-20000-41003	10700 W SANTA MONICA BLVD 212-214	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.05167	-118.432	NON-STRUCTURAL TI FOR (E) OFFICE BUILDING. PC FOR ENERGY ONLY. TOTAL AREA: 3,088 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36225	19041-10000-43425	7535 N VALJEAN AVE A	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.20747	-118.48616	REMOVED HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36226	16041-40001-26298	12950 W HAMLIN ST	91606	2	180B161   916	2326016016	R1-1, R3-1, [Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.18833	-118.4156	SUPPLEMENTAL PERMIT TO 16041-10000-26298 TO CORRECT ADDRESS FR:  12950 W. VICTORY BL. TO 12950 W. HAMLIN ST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36227	14041-10001-35068	1311 W SEPULVEDA BLVD	90501	15	045B193   791	7347018097	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			09/09/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	33.81492	-118.30044	09/09/16Changes to an approved set. All changes are made under delta 4. Upgrading elevator loads from 20HP to 50HP. Reorganizing distribution equipment due new sections, and revising motor contribution.(((((PC FOR POWER AND ENERGY FOR A NEW 6 STORY 176 UNITS APARTMENT BUILDING. TOTAL AREA 106800 SQ FT. B# 14010-10000-02205	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36228	14041-10000-19100	4510 W FRANKLIN AVE	90027	4	150B197   904	5590016028	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.10521	-118.28798	PC FOR ENERGY. TI FOR BANK OF AMERICA. TOTAL  AREA 1348 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36229	18041-10000-13334	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.32381	-118.49103	TI ON THE 1ST FLOOR OF AN EXISTNG COMMERCIAL BUILDING. PLAN CHECK FOR POWER ONLY.INSTALL A NEW 75 KVA TRANSFORMER, 2 PANELS AND CIRCUITS. REPLACE AN EXISTING 75 KVA TRANSFORMER (LIKE TO LIKE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36230	13041-10000-34470	6316 N TOPANGA CANYON BLVD BLD # B	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	07/24/2014 12:00:00 AM		Issued	07/24/2014 12:00:00 AM	ADDRESS	34.18578	-118.60514	PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING BBUILDING PERMIT # 13010-10000-02905.New 2 STORY retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36231	17041-10000-43763	850 N BROADWAY	90012	1	135A215   254	5408031013	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	PIN	34.06380239	-118.23717188	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36232	19041-20000-20214	6226 N COLFAX AVE	91606	2	177B169   283	2335032012	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Apartment			05/29/2019 12:00:00 AM	07/02/2020 12:00:00 AM		Permit Finaled	07/18/2022 12:00:00 AM	ADDRESS	34.18362	-118.3876	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36233	11041-10000-19373	4019 W SUNSET BLVD	90029	13	145-5A201 272	5429010027	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM			PC Approved	09/14/2011 12:00:00 AM	ADDRESS	34.09295	-118.28062	T-24 lighting plan check for restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36234	16041-10000-27260	260 S CARONDELET ST 11	90057	13	135A203    47	5154015008	R3-1	Central	Westlake	Westlake North	YES	2085.02	Electrical	Electrical	Apartment			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.0658	-118.27618	NEW FIRE ALARM FOR 11 UNITS APARTMENT BUILDING. INCLUDING 2 PANELS AND 22 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36235	19041-10000-14254	19236 W STARE ST	91324	12	204B117   518	2729026006	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.2527	-118.55249	$0 for finals fees due AB1414Plan check for a 16.775KW DC / 15.08 W AC PV1 roofmounted system with (1) load center, (55) IQ6 Plus microinverters and modules interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36236	19041-10000-25475	11117 W VICTORY BLVD	91606	2	180B173   616	2336001900	OS-1XL	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.18686	-118.3729	NEW FIRE ALARM SYSTEM IN THE BULDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36237	10041-10000-12355	1130 W C ST	90744	15	027B201    90	7417008038	M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	33.77182	-118.27581	Installing a new HPP (High Presure Pasturation) machine for State Fish Company,  New Service and panelboards. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36238	14041-20000-21302	924 N BEL-AIR ROAD	90077	5	144B153   763	4370026014	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.09003	-118.44094	NEW 3-STORY SINGLE FAMILY DWELING W/ BASEMENT, W/ ATTACHED 3-CAR GARAGE. PLAN CHECK FOR POWER ONLY. NEW 2000A SERVICE. 3 PHASE 208. NON HAZARDOUS.INVESTION FEE HAS BEEN ADDED FOR PERMIT ISSUANCE.DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36239	15041-20000-02762	12484 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36240	16041-10000-26506	1901 S AVENUE OF THE STARS 1400	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM			PC Info Complete	08/24/2016 12:00:00 AM	ADDRESS	34.05949	-118.41705	TITLE 24 FOR TI IN A EXISTING HIGHRISE BUILDING. LOCATION(14TH FLOOR SUITE #1400). (TOTAL 666 SQ. FT.). NEW LIGHTING ON AN EXISTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36241	14041-20000-19186	18050 W PARTHENIA ST	91325	12	195B125   856	2787001024	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/17/2014 12:00:00 AM	ADDRESS	34.22851	-118.52649	5KW PV1 roof-mounted system with (1) SolarEdge SE5000A-US inverter, (18) Trina Solar TSM 255P and SolarEdge P300 Power Optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36242	17041-30000-43981	6923 S KITTYHAWK AVE 1-25	90045	11	102B173   225	4103010030	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Issued	12/07/2017 12:00:00 AM	ADDRESS	33.97495	-118.37278	Plan check for a fire alarm system for an apartment building. Fire alarm system consists of (1) FACP and (76) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36243	12041-20000-11786	725 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	05/22/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	T.I. to existing high rise building on the 4th floor of suite #400.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36244	19041-20000-30818	10400 N NEVADA AVE	91311	12	204B101    58	2723017106	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.25925	-118.60927	Plan check for PV roof mounted system and Energy Battery back up system, PV system size: 7.04KW with 22 PV Modules and 1 inverter(7.0KW) and 1 LG Battery 9.8KWh, Auto transformer, back up load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36245	12041-10000-30159	2221 S LINCOLN BLVD	90291	11	108B149   343	4241034024	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	33.99467	-118.45449	PLAN CHECK POWER AND ENERGY FOR ADDITION AND CHANGE OF USE FROM HOTEL TO OFFICE. EXISTING TWO STORY BUILDING. NEW 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36246	16041-20000-32954	1940-1950 S PONTIUS AVE	90025	5	126B153   339	4323025005	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.04323	-118.44116	TI to (E) warehouse space.  New 400 A 240V 3 phase service.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36247	18041-10000-16459	2240 S COLBY AVE	90064	11	123B153   251	4260016003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM			Corrections Issued	05/03/2018 12:00:00 AM	ADDRESS	34.03498	-118.44398	PC  for TI in existing  AUTO REPAIR shop.  New office space and restroom for title 24 energy only. Design build projectTotal affected 1547 sq.ft Scope includes installing new lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36248	16041-20000-19908	669 W 34TH ST ROOM 340	90731	15	006B197   394	7467010022	RD2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2976.02	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	33.71324	-118.29139	PLANCHECK FOR POWER AND ENERGY.  ASSEMBLY OCCUPANCY AT USC. MRF AV UPGRADE ROOM 340.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36249	19041-20000-50637	8510 N BALBOA BLVD #220	91325	12	192B133    87	2689019016	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.2251	-118.50158	TENANT IMPROVEMENT ADD NEW LIGHTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36250	13041-20000-31884	12837 W NORTH SEAGLASS CIR	90094	11	102B161  1223	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	33.97473	-118.41872	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36251	14041-20000-11583	2300 W VALLEY ST 1-11	90057	13	135A205    71	5154012001	R3-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Apartment			05/01/2014 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.06553	-118.27365	New 18-unit 3-story apartment building. Plan check for power and energy.Fire alarm variance on file.Fees calculated for # of panels are slightly incorrect, fix during final.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36252	18041-30000-44486	933 E VERNON AVE	90011	9	112-5A209  33	5115013025	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2286.00	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	01/20/2021 12:00:00 AM	ADDRESS	34.00407	-118.25923	NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. 60 FA DEVICES AND 1 NEW FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36253	11041-10000-16982	16623 W SHERMAN WAY	91406	6	183B137    41	2226006016	QC2-1VL, QP-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.20138	-118.49523	T.I.  Remodeling of light fictures within an existing restaurant.  Restaurant is housed in a single story building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36254	14041-10000-00605	1297 S MAPLE AVE	90015	14	124-5A209 172	5145027044	M2-2D	Central		Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.03518	-118.25748	T24 for a commercial building, changing fixtures with existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36255	17041-10000-41006	901 E 12TH ST	90021	14	123A211    87	5132014001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Issued	01/03/2018 12:00:00 AM	ADDRESS	34.03208	-118.24959	PC for FA system for four story building with subtarreanean basement. Installing one FACP, four power suppply panel, one annunciator and 226 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36256	17041-10000-12190	810 S FEDORA ST	90005	10	132B197   538	5094016021	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.05734	-118.29749	PC for energy only, Outdoor Title 24. Remove HID fixutres and replace them with LED. Area:  6,280 SQft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36257	19041-20000-36929	13349 W FRIAR ST	91401	2	180B157  1032	2330002019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.18583	-118.42421	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 4.8KW DC/3.8KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH OPTIMIZERS AND A 3.8KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36258	17041-20000-22752	8620 N BLAUVELT PL	91325	12	195B129   477	2787035005	R1-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.22784	-118.52396	PLANCHECK ONLY FOR 2 STORY ADDITION TO A SINGLE FAMILY RESIDENCE. UPGRADE OF SERVICE TO 600 AMPS.building permit #12014-20000-00935	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36259	12041-20000-13017	1357 E 22ND ST	90011	9	120A211   404	5119004900	OS-1XL	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.0209	-118.25159	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36260	18041-10001-03969	6360 W 80TH PL	90045	11	099B165   714	4108026034	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	33.96605	-118.39833	Expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36261	16041-10000-02067	6248 N TEESDALE AVE	91606	2	177B161   199	2332013003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.18442	-118.40828	PV1, Install 4.505 kW DC / 3.6kWac roof-mounted solar array, interconnect with service panel. Transformerless inverter. (1) INVERTER:  ABB PVI-3.6-OUTD-S-US-Z-A.  (17) Modules: KYOCERA  KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36262	15041-10000-25608	621 W 54TH ST	90037	9	108B201   539	5001026013	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	33.99338	-118.28497	PV1, INSTALL 3.92 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(12) MODULES: SUNPOWER SPR327NE(1) INVERTER: POWERONE PVI-3.0-OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36263	19041-10000-23438	3580 W WILSHIRE BLVD #600	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.06156	-118.3028	ENERGY PLAN CHECK FOR  AN EXISTING OFFICE TENANT IMPROVEMENT LOCATED ON 6TH FLR   OF A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 20,950-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36264	16041-10000-39718	6517 N PEACH AVE	91406	6	180B145   536	2234018014	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.18921	-118.46781	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.52KWdc / 8.50KWac. USING STANDARD PLAN.(34)MODULES-HYUNDAI HIS-S280RG(34)MICROINVERTERS-ENPHASE M250-60-2LL-S2X	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36265	19041-10000-12811	1677 E 41ST ST	90011	9	114A213    14	5117015015	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.00827	-118.24365	Remove HID fixtures and replace with new LED fixtures (Outdoor only)  - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36266	16041-10005-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET.  ALL CHANGES ARE CLOUDED UNDER DELTA 12. CHANGES INCLUDE REVISING CONDUCTORS SIZES FOR FIRE PUMP TO REFLECT AS BUILT CONDITIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36267	17041-20000-24915	4940 N VAN NUYS BLVD 105	91403	4	169-5A151  37	2248007255	C1.5-1VL-RIO, R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Public Safety Only			07/24/2017 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	34.16043	-118.44849	additional 60 fire alarm devices to an existing facp.this is plan check only permit fees paid under 17041-90000-20335	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36268	19041-10000-49334	1138 S HOBART BLVD	90006	10	129B193   849	5080021005	R3-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.04972	-118.30509	[EPLAN] INSTALATION OF (2) NEW ESS (TESLA POWERWALL) TO AN EXISTING PV1 SYSTEM. CONNECTED TO A 100 AMP EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36269	13041-10000-28604	8055 W 3RD ST	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.07218	-118.36515	New Methane Mitigation Control System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36270	12041-10001-03206	2039 E CESAR E CHAVEZ AVE	90033	14	129A223    73	5175029005	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			04/06/2012 12:00:00 AM			PC Approved	04/06/2012 12:00:00 AM	ADDRESS	34.04886	-118.21202	TI in a retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36271	19041-10000-46797	3330 W OLYMPIC BLVD	90019	10	129B193   413	5080002025	R1-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	07/25/2020 12:00:00 AM	ADDRESS	34.05196	-118.31024	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36272	18041-20000-42465	2211 W SUNSET BLVD	90026	13	139-5A207  80	5402031021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1956.00	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.07778	-118.26564	Plan check for Title 24 only in existing space Yogurt Shop T.I. Total area: 650 sq ft. B#18016-20000-34387	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36273	18041-10002-34912	4470 N WINNETKA AVE	91364	3	165B113    20	2174026008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM			PC Approved	11/05/2018 12:00:00 AM	ADDRESS	34.15251	-118.57107	Change to approved set by updating the quantity of the module and replace all modules with different brand and rating.(((PLAN CHECK FOR ROOF MOUNTED 11.4KVA/13.75WDC PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE 11400A-US) WITH 50 MODULES USING P320 OPTIMIZERS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36274	18041-10006-02129	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	33.94248	-118.40461	Change to an approved set by combining some of the approved delta notation to the application. Scope inlcudes adding new ckts and modify some lighitng on the floor plan. All changes under delta-6 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36275	16041-10000-42325	701 N LAKME AVE	90744	15	030B209   335	7423012035	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	33.77887	-118.25992	PC FOR ENERGY. REPLACE OUTDOOR AND INDOOR  FIXTURES WITH NEW LED FIXTURES  TOTAL AREA 31700 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36276	14041-10000-08648	2000 S AVENUE OF THE STARS 3rd	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.05868	-118.41546	Title 24 and energy , high rise, no emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36277	10041-10000-20917	4733 W SUNSET BLVD Room#B2107	90027	13	147B197   604	5543012018	C2-CSA1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.09833	-118.29305	TI IN AN EXISTING OFFICE BUILDING IN ROOM # B2107 ON THE 2ND FLOOR.  PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36278	10041-30000-02900	8830 S SEPULVEDA BLVD	90045	11	096B165  1007	4123001005	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	02/18/2010 12:00:00 AM		Permit Finaled	04/08/2010 12:00:00 AM	ADDRESS	33.95623	-118.39595	PLAN CHECK T-24 ENERGY FOR INTERIOR TENANT IMPROVEMENT FOR 5,199 SF OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36279	15041-20000-12842	11952-11954 W VENTURA BLVD	91604	2	162B169   153	2369016032	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.14327	-118.39243	Plan check for T.I.  Dental office(Medical Office). Total area: 2082 sq ft. New 400A service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36280	12041-20004-30756	12001 W VICTORY BLVD	91606	2	180B165   700	2322007056	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.18684	-118.39464	Modification to approved set for LIGHTING CHANGE ONLY.<<<<Plan check for power and energy.  Bakery and kitchen. Less than 100 occupants. Electrical work was within the scope of work for the Civil Engineer. 8419sqft.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36281	14041-20000-22805	15844 W PARTHENIA ST	91343	12	195B141   763	2673005021	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.22819	-118.4778	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. DERATING MAIN TO 150A. USING 19 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36282	19041-10000-09174	12831 W MACLAY ST	91342	7	222B161   220	2525011007	A1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.3045	-118.41258	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36283	14041-10000-21006	14006 W RIVERSIDE DR SPACE 34	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC FOR ENERGY ONLY. TENANT IMPROVEMENT OF EXISTING RETAIL STORE. TOTAL AREA 1700 SQ FT. PLAN WAS SUBMITTED BECAUSE OF TAILORED METHOD AND NEW TITLE 24 FORMS HAS TO BE SUBMITTED. PLAN CHECKER TO NEGOCIATE TO NABIL. B. APP # 14016-10000-14735.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36284	12041-10000-19494	16437 W VENTURA BLVD	91436	5	168B137   804	2260009043	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Finaled	09/18/2012 12:00:00 AM	ADDRESS	34.15766	-118.49151	PLAN CHECK POWER AND ENERGY. ADDING NEW BRANCH CIRCUITS AND NEW LIGHTING ON EXISTING CIRCUITS FOR CHASE BANK TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36285	16041-30000-07656	6801 S PARK TER	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.97698	-118.39328	Plan check for Title 24 only for T.I. in common area in elevator lobby, 1st to 5th floor. Total area: 1,966 sq ft. Luminaire Modification in place < 40 Luminaires; existing lighting controls are permitted	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36286	18041-20000-14646	21837 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.16859	-118.6032	Plan check for power and energy change of use from retail to Medical office Motion Stretch Studio 2,052 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36287	13041-10001-30369	1810 N STANLEY AVE	90046	4	150B177   536	5551011017	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.10384	-118.35605	Expedited RSES plan check per aplicant request.(((PV1, Instal 6.75 kW DC roof-mounted solar array for a house, interconnected  with the main service panel. NO batteries. Microinverter.25 modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36288	10041-10002-16673	6515 S NORMANDIE AVE 1-20	90047	8	105B193  1578	6015008017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Apartment			12/23/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	33.98012	-118.30055	Delta A revision to approved plans. Indicating service entrance conductors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36289	15041-20000-21835	13631 W OSBORNE ST	91331	6	198B157   471	2642022015	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.23917	-118.43039	Plan check for a PV1 roof-mounted PV system. System size is 3.9 kWac and consists of (18) micro-inverters, (18) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36290	16041-30000-30232	800 W WILSHIRE BLVD Ground FL	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.0493	-118.25841	Plan check for Title 24 only in existing space in high-rise building T.I. in Bar area. Total: 2,310 sq ft.Building permit#16041-10000-17948	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36291	15041-10000-24331	2210 S MAIN ST	90011	9	121-5A207  69	5127028024	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	PIN	34.02772977	-118.26635824	PC FOR ENERGY ONLY, T-24. SCOPE INCLUDES NEW LED FIXTURES. TOTAL SQ. FT. 4784	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36292	18041-20001-43802	6130 N NEVADA AVE	91367	3	177B101   329	2146003035	R3-1, R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.13	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	ADDRESS	34.18174	-118.60982	2/19/19changes to an approved set of plans.  changes to indoor light fixtures and energy calculations.  this is plan check only.  ((((ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  new load connected to an existing service plan check for power and indoor energy only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36293	13041-20000-27330	4711 N SAN FELICIANO DR	91364	3	165B101    53	2076020045	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.15223	-118.61072	PV1 MICROINVERTER STANDARD PLAN. 4.9KWAC SYSTEN. 23 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36294	15041-20000-06916	1432-1436 N CURSON AVE	90046	4	147B177  1112	5550026006	R3-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Apartment			03/10/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.09714	-118.35488	Plan check for power and Title 24 (energy).  Total area = 7,118 sq. ft.New 3-story 9 unit apartment building with 800 A service.  Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36295	15041-20000-10943	3107 W BEVERLY BLVD 3107-3115	90026	13	138A201   209	5156010010	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	PIN	34.07222667	-118.28234888	Title 24 plan check only.  Total area = 21,290 sq. ft.T.I. to existing two story commercial retail space.  Switchgear and panels to remain existing.  New branch circuit connected load is approximately 230 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36296	16041-20000-35306	4136 N DIXIE CANYON AVE	91423	4	165B157  1099	2373004003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.14476	-118.42471	Plan check for 8kW battery back up system for SFD. (1) Sonnen Eco16 8kW integrated storage w/ (8) 48V batteries. Back up system is being installed between an existing solar system/inverter and a distribution panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36297	16041-20001-33052	3601 S TROUSDALE PKWY 3rd-4th Floors	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.02017	-118.28558	Revisions to approved plan set.  Includes additional scope to TI work - (2) new office and work room.   Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36298	16041-20000-44699	627 S MORENO AVE	90049	11	126B137    53	4264005018	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.04428	-118.48553	Plan check for power only. New 2 story SFD with basement and attached garage. 1000A service.Note: Electrical permit fees paid under Building Combo permit. Building permit pulled under application number 16010-30000-01744.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36299	18041-10000-41214	2313 W JEFFERSON BLVD	90018	10	120B189   629	5052006008	C2-1VL-O-HPOZ-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.02571	-118.32056	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36300	19041-20000-11929	13160 W MINDANAO WAY Ste 170	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	05/01/2024 12:00:00 AM	ADDRESS	33.98501	-118.43726	Plan check for power and energy. Project site is an existing dental office. Project scope is a tenant improvement. Total lighting area = 2,067 sq. ft.Note: Building application has been generated under 19016-20000-08738	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36301	13041-10001-34359	2717 N LAUREL CANYON BLVD	90046	4	156B173   638	5565038004	RE15-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.12005	-118.37539	Expedited RSES plan check per applicant request.{{{PV1, install 2.5 kw DC roof-mounted solar array for a 2-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. (10) modules: Trina Solar TSM-250PA05.18.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36302	17041-10000-33541	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Info Complete	09/19/2017 12:00:00 AM	ADDRESS	33.94572	-118.40095	NEW 422 SQFT COFFEE SHOP  AND FOOD STORAGE ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36303	12041-10000-20690	333 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   594	2424044021	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.13838	-118.35964	Plan check for T24 Energy/emergency lighting for studio area (hotel function) and performer area on the 1st floor .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36304	16041-10001-07496	1575 N GOWER ST	90028	13	148-5A189 330	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	Changes to approved set of plans to reflect changes on field. Changes to title 24, changes under delta 9. Addition and revision of luminaires in exisitng and new space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36305	17041-10000-06949	10880 W WILSHIRE BLVD 122	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.05885	-118.44283	PC for energy, lighting only. on first floor of a high rise building. Change of use from office to office/adult education. Area: 7,356.Permit has already been paid under applicaton #17041-40000-04007.Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36306	12041-10000-29254	380 WORLD WAY Suite-6C4-10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	6TH FLOOR FULL TENANT IMPROVEMENT FOR AIRLINE LOUNGE. BUILD-OUT WITHIN LAX CORE AND SHELL. EQUIPMENT INCLUDES TWO MOTORS AND TWO TRANSFORMERS. TITLE 24 AND EMERGENCY LIGHTING ( LTG FORMS WERE NOT SUBMITTED AS PART OF THE PLANS,  AND NO PHOTOMETRICS WERE PROVIDED). THE SERVICE IS EXISTING. ADDRESS LOCATED IN METHANE ZONE. BUILDING APPLICATION NUMBER IS: 12041-10000-23893	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36307	10041-10000-15203	6842 N VAN NUYS BLVD 4th Flr.	91405	6	183B149   647	2217009011	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	08/31/2010 12:00:00 AM	ADDRESS	34.19499	-118.44846	T.I. to existing high rise building (4th Floor).  Install general/emergency lighting.  Additonal P/C may be required subject to inspection.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36308	17041-10002-35423	330 W 58TH ST	90037	9	108B201  1300	5101040009	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	33.98958	-118.27974	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36309	13041-10000-06914	23318 W CALVERT ST	91367	3	177B093   557	2035001009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Expired	04/02/2015 12:00:00 AM	ADDRESS	34.18068	-118.63497	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. MICROINVERTER USING ENPHASE M215 STANDARD PLAN. TOTAL SYSTEM SIZE 3.024KW USING 14 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36310	11041-10000-18481	6150 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Public Safety Only			08/30/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	33.94474	-118.39224	NEW FIRE WARNING SYSTEM FOR RMT LAX HANGER ; TO BE USED IN CONJUCTION WITH EXISTING SYSTEM THAT MONITORS THE SPRINKLER SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36311	19041-10000-52041	107 S HEWITT ST	90012	14	129A215    97	5163002006	CM-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM	01/27/2021 12:00:00 AM		Permit Finaled	03/10/2023 12:00:00 AM	PIN	34.04847596	-118.23625509	NEW MIXED USED BUILDING WITH A NEW 3,000 AMP SERVICE, PANELS AND CIRCUITS. PLAN CHECK FOR POWER & ENERGY. (((((BUILDING PERMIT: 19010-10000-00001 -- ***60% PDPP submittal for Zoning, life and safety and Disabled Access only. *** New 6-story 69-unit  apartment building III-A over subterranean basement garage, commercial uses I-A. TOC Tier 4  project. ))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36312	17041-20000-45534	13571 W VAUGHN ST	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.27758	-118.42846	PV2. ROOFMOUNTED FEED-IN TARIFF PHOTOVOLTAIC SYSTEM. SYSTEM SIZE: 2217.53 KW.  RESUBMITTAL TO PERMIT 15041-20000-08646(5614)  LG395 395 WATT MODULES(30) SMA 24(23) SMA 23(18) SMA 1857BUILDING PERMIT # 15016-20000-20234	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36313	19041-10000-36390	10901 W RIVERSIDE DR	91602	4	165B173    48	2423009049	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	NoHo		1432.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	05/28/2021 12:00:00 AM		Permit Finaled	04/14/2022 12:00:00 AM	ADDRESS	34.15243	-118.36779	FULL PC FOR A NEW 2-STORY (4,687SF) DRIVE-THROUGH RESTAURANT, SCOPE OF WORK INCLUDES NEW 1,000A SERVICE (208/120 3P 4W) FEEDING A 1,000A SWITCHBOARD THAT FEEDS SEVEN SUBPANELS AND VARIOUS HVAC EQUIMENT. TOTAL AFFECTED AREA IS 24,294 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36314	15041-10000-05935	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM			PC Approved	03/02/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING CONTROLS AND PANEL.  TOTAL SQUARE FOOTAGE 619.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36315	13041-10001-31541	1417 W SILVIUS AVE	90731	15	009B193  1016	7470024015	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	33.71614	-118.30867	Expedited RSES plan check per applicant request.(((PV1, Install 3.75 kW DC roof-mounted solar array for 2-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36316	12041-10000-31054	10911 N SUNNY BRAE AVE	91311	12	210B109   293	2707025016	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.26849	-118.5807	pv for single dwelling unit. 1 story unit. enphase m215 microinverter. sunodule sw 240 poly.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36317	14041-20000-21499	4311 S AVALON BLVD	90011	9	114A207   347	5113013025	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.00534	-118.26544	Plan check for power and energy. Tenant improvement, convert existing church into a new coin laundry and a future retail space. All loads and equipment is new. 5,440sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36318	19041-20001-41667	8618 N SHIRLEY AVE	91324	12	195B117   370	2783019014	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Issued	12/30/2019 12:00:00 AM	ADDRESS	34.22693	-118.5578	PV1. INSTALL 8.40 KW DC PV SYSTEM WITH (21) MODULES AND MICROINVERTERS. PARTIAL INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-41667	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36319	15041-20000-02079	9541 N AMESTOY AVE	91325	12	201B133   575	2692018025	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.24452	-118.50695	PV1 SFD. TOTAL SYSTEM SIZE 10.3KW AC USING 43 MICROINVERTERS. MODEL ENPHASE M250. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36320	18041-10000-11164	3100 W SUNSET BLVD	90026	13	142-5A203 287	5426016008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.08441	-118.27456	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM AN EXIST SERVICE STATION TO AN ICE CREAM RESTAURANT. TOTAL AFFECTED AREA IS 12059 SQ. FT. B#16016-30000-01549	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36321	14041-20000-04714	8316 N GAYNOR AVE pv1	91343	12	192B141   449	2673018054	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Expired	05/05/2016 12:00:00 AM	ADDRESS	34.22184	-118.48181	pv1, roof mounted solar installation, interconnecting with (E) 200a main service PNL. downsizing main breaker for tie-in. ungrounded system, sized @ 5.75 kW DC, with (23) canadian solar #cs6p-250px, (23) OP300 power optimizers, (1) solaredge #SE5000a-us-zb-u	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36322	19041-10000-14921	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.11883	-118.2495	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36323	16041-10000-03359	13023 W CORCORAN ST	91340	7	216B161   169	2514018011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.2885	-118.41698	PV1, ROOF MOUNTED SOLAR SYSTEM USING OPTIMIZERS. (20) MODLUES, (20) SOLAR EDGE OPTIMIZERS AND 1 INVERTER. TOTAL SIZE 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36324	11041-10000-16740	505 S FLOWER ST STE B430	90071	9	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	09/27/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.0515	-118.25654	PLAN CHECK ONLY FOR POWER PER APPLICANTS REQUEST FOR TI TO AN EXISTING RESTAURANT.  (PLAN CHECK FOR ENERGY WAS ALREADY APPROVED).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36325	15041-10000-09116	4082 DEL REY AVE	90292	11	108B153  1186	4230005001	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM			PC Info Complete	04/14/2015 12:00:00 AM	PIN	33.98905782	-118.44497988	PC FOR POWER. A PANEL INSSTALLED AT BLDG 4082 FED FROM 4086 MAIN DB. PLAN CHECK 4086 SUBMITTED UNDER 15041-10000-09111.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36326	18041-20000-29347	1135 N MANSFIELD AVE 3rd Floor	90038	4	144B181   376	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Issued	08/07/2018 12:00:00 AM	ADDRESS	34.0918	-118.34057	Plan check for Title 24 only. Project site is the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,359 sq. ft.Note: Building application has been generated under 17016-10000-27741	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36327	18041-10000-01272	2015 S GREENFIELD AVE	90025	5	126B153   250	4323015022	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	06/09/2018 12:00:00 AM	ADDRESS	34.0441	-118.43749	NOTE: PERMIT FEES ARE $0 DUE SENATE BILL 1222.NEW ROOFTOP SOLAR SYSTEM CONSIST OF 26 MODULES (SOLAR CITY STANDARD #SC325), OPTEMIZERS (SOLAREDGE P400) AND A CENTRAL INVERTER (SOLAR EDGE SE7600A @ 7.6KW).  SYSTEM SIZE IS 8.45KWdc and 7.6KWac.SCOPE INCLUDES 3 ENERGY STORAGE SYSTEMS (TESLA POWERWALL 5.8KVA/13.5KWH) UNDER PERMIT 18041-10002-01272), NEW 200A  LOAD CENTER AND 200A DISTRIBUTION PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36328	16041-10000-14238	5452 W ADAMS BLVD	90016	10	123B177  1064	5043008006	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.0323	-118.36176	Full PC, TI and change of use from existing warehouse to food processing/warehouse. Scope of work includes a new 600 amp overhead service, new lighting and receptacles. Total Sq. Ft. 7142.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36329	15041-20000-36018	18226 W VENTURA BLVD #103	91356	3	171B125   309	2181010028	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.16616	-118.52995	Plan check for Title 24 only for T.I. in existing space. Total area: 2,392 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36330	18041-20000-20730	20949 W SATICOY ST	91304	3	186B109   217	2109023002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.20845	-118.59029	Plan check for PV roof mounted system, system size: 7.6kW with 25 modules and 1 inverter(7.6kW) connected to center feed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36331	15041-10000-44080	1925 S CENTURY PARK EAST 14th floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24, TI TO THE 14TH FLOOR OF A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES, NO NEW PANELS. TOTAL SQ. FT. 9425.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36332	19041-20002-29065	22620 W AVENUE SAN LUIS	91364	3	171B097   517	2075010011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM			PC Approved	10/08/2019 12:00:00 AM	ADDRESS	34.16541	-118.61868	09-27-2019 Changes to an approved set of plan, Changes include relocate PV Modules on roof. All changes has been clouded. Plan check only.Fees $0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36333	13041-20000-15780	12718 W TIARA ST	91607	2	177B161  1012	2341009011	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.17835	-118.4101	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.4 KW. USING 16 MICROINVERTERS ENPHASE M215. USING STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36334	17041-20000-18062	7510 W HOLLYWOOD BLVD	90046	4	147B177   381	5550011022	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.10151	-118.35323	SERVICE UPGRADE TO 600 AMPS AND NEW DISTRIBUTION EQUIPMENT FOR (E) 16-UNIT APARTMENT BUILDING.  PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36335	11041-20000-10621	941 E 2ND ST	90012	9	129A217   108	5163005001	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.04727	-118.23375	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36336	16041-20000-21788	20278 W JUBILEE WAY	91326	12	216B113     1	2701002076		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.28336	-118.57597	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36337	12041-10000-27407	17137 W INDEX ST	91344	12	210B133    88	2697013013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Expired	02/20/2015 12:00:00 AM	ADDRESS	34.27571	-118.50627	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 11.76KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36338	12041-10000-03307	800 W WORLD WAY Terminal 8-#8B	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM			PC Approved	02/28/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	T.I. to an existing retail space at LAX airports,  Terminal 8, Space 8B.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36339	18041-10000-26036	1119 N MCCADDEN PL 1-26	90038	4	144B185   650	5532020013	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			07/25/2018 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	03/31/2021 12:00:00 AM	ADDRESS	34.09138	-118.33766	"** SEE APPLICATION COMMENTS*****[100% AFFORDABLE HOUSING - RUSH TAG, ASSIGN 25% FASTER] PC FOR POWER AND ENERGY FOR A NEW 4 STORY "" LOW INCOME"" APARTMENT BUILDING (26 UNITS). NEW SERVICE RATED AT 1600A 3PH 120/208SCOPE INCLUDES NEW SERVICE, PANELS, EQUIPEMNT AND LIGHTS. TOTAL AFFECTED AREA 15300 SQ.FT (INDOOR) B#17010-10000-04057"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36340	14041-10000-19430	5733 W ARBOR VITAE ST	90045	11	093B169    65	4125010005	MR1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM			Verifications in Progress	08/05/2016 12:00:00 AM	ADDRESS	33.95278	-118.38209	Plan check for power and lighting.  Total area = 25,317 sq. ft. indoor 63,875 sq. ft. outdoorRemodel of existing industrial building - large scale auto repair shop.  New switchboard, pannelboards, motors, and lighting.  Building application submitted before title 24 part 6 effective date.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36341	18041-10001-01681	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Public Safety Only			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.06047	-118.29555	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE ADDING 6 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36342	11041-20000-03792	116 N ROBERTSON BLVD 8th Floor	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM			PC Approved	03/21/2011 12:00:00 AM	ADDRESS	34.0758	-118.38356	Plan check only. Plan check for T24 Energy (general/emergency) lighting on the 8th floor. Permit under #11041-90000-04331	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36343	15041-10000-05900	3029 W 8TH ST	90005	10	132B197   455	5094011009	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.0579	-118.29239	RENOVATION OF EXISTING FACILITY WITH 600A SERVICE.  NO CHANGE OF USE.  ALL EQUIPMENT NEW.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36344	12041-20002-24451	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.30237	-118.46212	"Plan check for chagnes to approved set of plans. Small changes to lighting and addition of two air-handler units (each fused at 15A).Modification to previously approved plans, changing equipment ratings and adding additional load.  PLAN CHECK ONLY FOR ""DELTA 4"" CHANGES         <<<< electrical and lighting, for a new 3000A service for industrial building (Plant 1).  Install new switchgear, panels, equipment and lighting.  Plan check for power and energy.  Plan check to charge fees for any new equipment installed.  Review original set of plans for prior approval.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36345	18041-10002-08117	20000 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Issued	04/08/2019 12:00:00 AM	ADDRESS	34.27519	-118.57042	Changes to an approved set of plans. All changes are clouded under delta 8. Changes include revising homeruns, adding/removing lighting fixtures, and revising panel schedules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36346	13041-20000-16257	6255 W SUNSET BLVD #1806	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM			PC Approved	06/19/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	Change to lighting and receptacles to an existing office space in a high-rise building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36347	14041-10000-10510	1630 W 1ST ST	90732	15	018B193   703	7559014029	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	33.74414	-118.31293	PV1, INSTALL 6.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(27) TRANSFORMERLESS INVERTER: SOLAREDGE # SE6000A-US-ZB-U(1) MODULES: CANADIAN SOLAR # SC6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36348	12041-10000-11417	21255 W BURBANK BLVD 3RD FLR-SUITE	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	08/29/2012 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT ON THE THIRD FLOOR OF A 6-STORY HIGH RISE BUILDING, 3RD FLOOR SUITE ONLY. CORRIDOR AREA ON SEPERATE APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36349	13041-20000-11135	1655 N HILLHURST AVE	90027	4	147B197   348	5542003022	RD1.5-1XL	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.10105	-118.28763	13041-20000-11135T24 FOR EXISTING RETAIL SPACE PART OF A 2 STORY MIXED USE BUILDING. SCOPE OF WORK ON SUITE 102. 1010 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36350	18041-10000-01954	5850 S VERMONT AVE Tenant B	90044	9	105B197    72	6004001024	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	33.98773	-118.29129	PC for power and energy for first time tenant build out of Ross store. Installing four new panels, new lights, receptacles and equipment. Total area is 28971sqft. B# 18016-10000-01658.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36351	17041-20000-34415	1110 S MAGNOLIA AVE	90006	1	130-5A201 291	5076013002	R3-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			09/26/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.05047	-118.28638	Plan check for power and energy. (N) 9-unit, 3-story apartment building with ground level parking. 2 typical units. 600A 1ph 3w service. T24 area - 6,650sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36352	13041-20000-24867	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.07157	-118.36014	Outdoor Farmers Market. Change to lighting.  PLAN CHECK ONLY for Energy.  Permit fees are for 23 lights on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36353	14041-20000-25276	11647 W HUSTON ST	91601	2	168B169   166	2354009013	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.15961	-118.38707	PV1Central/String inverter simplified standard planInstall roof-mounted solar array on SFD, interconnect with SFD. System size: 5kW.(1) ABB PVI-5000-OUTD-US transformerless inverter(16) Canadian Solar CS6X-310P pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36354	18041-10000-10014	7900 N HASKELL AVE	91406	6	189B141   153	2206001021	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Issued	03/20/2018 12:00:00 AM	ADDRESS	34.21408	-118.47476	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36355	18041-20001-00136	12015 N MIRABEL WAY	91326	12	216B109   170	2701081019	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.29099	-118.58237	Plan check for lost set of plan. pv1install roof mounted pv system sized sized 4.8kw interconnected with msp.fees $53.68 due California Senate Bill 1222 and Assembly Bill 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36356	15041-20000-00778	9280 W NIGHTINGALE DR	90069	4	150B169  1384	5561007023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Expired	08/25/2017 12:00:00 AM	ADDRESS	34.10343	-118.39095	NEW SINGLE FAMILY DWELLING 1600 AMP SERVICE.  PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36357	12041-10000-10348	624 S GRAND AVE	90014	15	015B197   491	7451037001	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	PIN	33.73811021	-118.28994388	Plan check for new four 800A switchboards and two 225KVA xfrmrs to support future installation of new DC Plant on the 28th Floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36358	19041-10000-42729	21110 W OXNARD ST	91367	3	177B105    76	2149002023	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/01/2022 12:00:00 AM	ADDRESS	34.17903	-118.59355	NEW FIRE ALARM SYSTEM PC SUBMITTAL. INCLUDES 1 FIRE ALARM PANEL, 8 POWER SUPPLIES AND 466 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36359	18041-10001-03991	603 E 115TH ST	90059	15	087A207   339	6072004027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Approved	04/12/2018 12:00:00 AM	ADDRESS	33.93021	-118.26482	[[4/12/18 CHANGES TO APPROVED T24 ENERGY. PLANCHECK ONLY. CHANGES ARE CLOUDED. CHANGING TO LIGHTING AND THE FIXTURE TYPE. ]]Plan check for Title 24 for existing lighting. add new lighting control to existing lighting. Total area: 9744 sq  ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36360	15041-10000-22107	11315 S FIGUEROA ST Ste 109	90044	8	087A201   235	6075026029	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	PIN	33.93143118	-118.28297189	TI to (E) commercial space for 1,100 sq. ft. lending institution.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36361	16041-30000-31143	1151 S BOYLE AVE	90033	14	123A219   119	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	PIN	34.0318367	-118.22119376	Plan check Title 24 only in existing space, remove outdoor lighting fixtures and replace wiht new LED lighting fixtures. Total area: 78,175 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36362	18041-20000-20128	15148 W BLEDSOE ST Suite A&B	91342	7	222B145   121	2506002030	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.30689	-118.46319	Plan check for Title 24 Energy only in existing space T.I. new lighting. Total area: 5964 sq ft.B#18016-10000-01385	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36363	10041-10000-08745	4216 W FOUNTAIN AVE	90029	13	147A201   248	5429008029	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Griffith Park	YES	1954.00	Electrical	Electrical	Public Safety Only			05/11/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	34.09566	-118.28135	NEW FIRE WARNING SYSTEM  IN A MEDICAL OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36364	14041-10001-12857	16258 W SHADOW MOUNTAIN DR	90272	11	132B121   298	4420039018	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.05743	-118.53911	(((EXPEDITE FEES)))PV1 MICROINVERTER PLAN. SERVICE SIZE 600AMPS. TOTAL SYSTEM SIZE 19.7KW. 73 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36365	17041-10000-01742	333 S GRAND AVE #1500	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Info Complete	01/18/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Title 24 only in existing high rise  building T.I. office space. Total area: 1,162 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36366	16041-10001-21830	7051 W ESTEPA DR	91042	7	198B201    25	2564013006	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.24232	-118.2847	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE DIFFERENT PANEL SIZE AND INVERTER SIZE. NEW SIZES NOTED. PANEL UPGRADE TO 225APC FOR A SOLAR GROUND MOUNTED SYSTEM. TOTAL SYSTEM SIZE IS 11.16KWdc / 10.08KWac(36)MODULES- LG320(36)MICROINVERTER-M280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36367	15041-20000-33874	2151 S AVENUE OF THE STARS 2ND FLR	90067	5	132B161   193	4315019006	R4-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.05439	-118.41225	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING ON 2ND FLOOR (HOTEL/MENS LOCKER ROOM/BATHROOM/SPA). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 660 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36368	16041-20000-45831	11111 W OLYMPIC BLVD 1,2,4 FLRS	90064	5	126B153   787	4322025046	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	08/30/2017 12:00:00 AM		Issued	08/30/2017 12:00:00 AM	ADDRESS	34.0401	-118.43851	Plan check for energy only. TI to existing building. Floor 1 retail, floor 2 offices, floor 4 offices/restrooms/corridor. New lighting (incl. emergency) and receptacles. 15,882sqft. See comments.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36369	15041-20001-37643	1301 N MONACO DR	90272	11	129B133    47	4425014013	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2015 12:00:00 AM			PC Approved	11/30/2015 12:00:00 AM	ADDRESS	34.05346	-118.50125	**Fee expedite***PV1, roof mounted solar panel, 13.8kW DC(46) modules: LG ELECTRONICS LG300N1K-G4, 300W(46) micronverters: ENPHASE M250-60-2LL-S2X	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36370	16041-10000-22108	358 E 118TH PL	90061	15	084B205   895	6083023001	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Expired	07/30/2018 12:00:00 AM	ADDRESS	33.92538	-118.2674	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.6KWac.(19)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB# PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36371	16041-10000-14617	300 S SANTA FE AVE Suite # D	90013	14	127-5A217  54	5163017900	(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	1ST TIME TENANT, a restaurant on a New construction mixed-use building. Full plan check, total area: 1,735 sq. ft.**Early permit is filed on 4/28/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36372	19041-20000-36500	10856 N CARTWRIGHT DR	91311	12	210B113   257	2708030020	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.26832	-118.56615	PLAN CHECK FOR PV ADDITION TO SFD WITH ENERGY STORAGE. SYSTEM SIZE IS 16.38KW DC/15.6KW AC. SCOPE OF WORK CONSISTS OF (52) PV MODULES, (3) 5.2 KW INVERTERS, AND (2) LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36373	17041-20000-39363	12764 W NEWTON ST	91342	7	222B161   481	2525024047	RS-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.30145	-118.41125	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter and (18) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36374	16041-10000-05576	3434 S 6TH AVE	90018	10	120B189   886	5044026013	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.02453	-118.32345	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(6)MODULES-KU2606XPA(1)INVERTER-PVI-3.0-OUD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36375	18041-20000-27353	5140 N LANKERSHIM BLVD	91601	2	171B173   743	2353005017	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.16412	-118.37398	Change of use from retail to restaurant - assembly occupancy with over 100 occupants.  Plan check for power and energy.  (E) distribution equipment throughout.  Building permit under 17016-20000-36499.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36376	16041-10000-05838	10880 W WILSHIRE BLVD SUITE 1850	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM			PC Info Complete	03/08/2016 12:00:00 AM	ADDRESS	34.05885	-118.44283	INTERIOR TENANT IMPROVEMENT TO EXISTING OFFICE SPACE (SUITE 1850), TOTAL AREA 2,295 SQ.FT. PC FOR T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36377	10041-10000-17648	1200 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.05052	-118.22672	Solar voltaic system installed on the roof of the building.  Consists of  6 modules,  6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36378	14041-20000-07201	10954 N WHITEGATE AVE	91040	7	210B193   765	2552016026	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.26861	-118.30517	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36379	17041-10000-36567	5522 W 79TH ST	90045	11	099B173   672	4127022015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	33.96465	-118.37611	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 3.8KVA CONSISTING OF CENTRAL INVERTER(SE3800H-US) AND 15 MODULES USING POWER OPTIMIZERS(P-320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36380	10041-10000-18714	8500 W BEVERLY BLVD # 859	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	11/05/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E)  SANDWICH SHOP-STONE OVENPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36381	14041-10002-31990	333 N BELMONT AVE	90026	13	136-5A207 221	5159003006	R4-1	Central	Westlake	Greater Echo Park Elysian		2083.02	Electrical	Electrical	Apartment			02/09/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.06787	-118.26342	02/09/2017 Changes to an approved set of plan. Changes include remove control in the common area, revised Title 24 calculation and revised lighting in commom area, distribution changed from (1)1600A to (2) 800 distribution. Changes apply to delta 10 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36382	11041-10000-02345	1645 N WILCOX AVE	90028	13	148-5A187 179	5547016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.10102	-118.33116	Electrical plan check for a RENOVATION OF EXISTING RESTAURANT AND BAR. KITCHEN, TOILET, BAR AND ENTRY. REMOVE THE 2ND FLOOR/ MEZZANINE.  ADD NEW MOMENT FRAME AND STRUCTURAL SUPPORTS.Approved per ZA 2007-2542 (CUB)(CUX) for 201 patrons	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36383	14041-10000-30190	5816 N WHITSETT AVE 1-23	91607	2	174B165   155	2340015016	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.17612	-118.40506	Fire Alarm system with total 115 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36384	16041-10000-08677	7945 N TOPANGA CANYON BLVD	91304	3	189B101   290	2012012016	(T)(Q)R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.21507	-118.60621	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 11521.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36385	16041-30000-12125	21935 S HARVARD BLVD	90501	15	048B193   276	7346010036	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM			PC Info Complete	04/18/2016 12:00:00 AM	ADDRESS	33.8284	-118.30671	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size =  5.59 kWac.  Microinverter system with two branch circuits and 125 A solar only load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36386	17041-10000-21930	4851 S ALAMEDA ST F-G	90058	9	111A215    13	5106027002	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	33.99921	-118.23904	PC FOR TITLE-24, ENERGY ONLY. IN COMM. BUILDING (INDUSTRIAL).INSTALLING NEW LIGHTS ON EXISTING CIRCUITS. TOTAL AFFECTED AREA 79,482 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36387	19041-10000-24757	401 N STATE ST	90033	14	129A221     5	5174008037	C2-1-RIO-CUGU, [Q]R5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.04923	-118.21593	Plan check for removing HID fixtures and replace with new LED Fixture for outdoor area with a total lighting fixture of 10975-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36388	17041-10000-38167	10250 W SANTA MONICA BLVD # 1070	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check (Power+Energy), tenant improvement of Existing tenant ""H&M"", New 800A distr. board, (8) panelboards, (3) transfomers 30kVA, 75kVA, 112.5kVA, and other motor loads. Total area under the scope:  30,000 sq.ft"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36389	13041-10000-30387	8940 W THRASHER AVE	90069	4	147B169   695	5561024012	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.09791	-118.38604	PLAN CHECK FOR POWER ONLY. UPGRADE OF SERVICE FROM 400 AMPS TO 600AMPS FOR A HOUSE.  Loads are existing to be reconnected to new panels M1, P1, P2, L1, and L2. New EV charger.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36390	14041-10000-00743	1458 S SAN PEDRO ST #107	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in Fashion District retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36391	15041-10000-19321	5158 N LAUREL CANYON BLVD	91607	2	165B161   384	2375009015	[Q]C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Expired	07/14/2017 12:00:00 AM	ADDRESS	34.16464	-118.39628	REPLACE EXISTING LIGHTING UNDER ARCO CANOPY WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY. TOTAL HARDSCAPE AREA 17459.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36392	17041-20000-21278	9133 BALLARD DR	91311	12	198B101   298	2727021024	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM				pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36393	09041-10001-04397	1327 E 21ST ST	90011	9	120A211   274	5119001021	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Southeast / Central Avenue		2270.10	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM			PC Approved	04/28/2010 12:00:00 AM	ADDRESS	34.02205	-118.25153	Delta 2 revisions to permitted set of plans- revised lighting plans and tile 24 compliance forms; reduced loads supplied from panel 1la and show it on the schedule and on the single line diagram; added and deleted a few receptacle. All changes are bubbled on the plans and identified with a delta 2 marking	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36394	16041-10000-32609	3641 S WELLINGTON ROAD	90016	10	120B185  1396	5046021023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	10/22/2016 12:00:00 AM	ADDRESS	34.02189	-118.33841	Plan check for PV roof mounted system. System size: 4.8kW with 15 modules and 15 microinverter S280.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36395	19041-10000-11966	5950 S BROADWAY	90003	9	105B201   399	6005014013	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	33.98583	-118.27809	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36396	10041-20000-22902	651 N SEPULVEDA BLVD #A1	90049	5	138B145    95	4368016042	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest		YES	2622.00	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	01/29/2011 12:00:00 AM	ADDRESS	34.07701	-118.46914	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36397	16041-20001-43726	801 S HOPE ST 1st Floor	90017	14	129A209   268	5144030***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Issued	03/30/2017 12:00:00 AM	ADDRESS	34.04656	-118.25938	changes to an approved set of plans.  changes include connecting the em lighitng to the existing building generator.  plan check for em and egress lighitng.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36398	18041-10000-02732	746 W 17TH ST	90731	15	012B197   526	7454035022	R2-1XL	Harbor	San Pedro	Central San Pedro		2969.01	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	33.72891	-118.29351	New PV1 rooftop on a single family dwelling, using center-fed per 93.0705.12(0)(2)(3)(e ) TIA. System size 6.6 kW AC/ 7.2kW DC. (24) modules with rapid shutdown boxes, and (1) inverter	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36399	19041-20000-45716	751 W 129TH ST	90247	15	081B197   355	6117021025	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	33.9155	-118.28879	PV1. INSTALL 2.925 KW DC ROOF MOUNTED PV SYSTEM WITH (9) MODULES/OPTIMIZERS AND (1) 3.0 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36400	18041-10000-27023	425 E SWINFORD ST	90731	15	021B201   197	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	07/17/2020 12:00:00 AM	ADDRESS	33.7497	-118.27718	NEW PV SYSTEM MOUNTED ON CARPORTS WITH 3080 PV MODULES AND 34 INVERTERS WITH 480 VOLT OUTPUT. SYSTEM SIZE  1.34 MWDC/  980 KWAC$0 due to Senate Bill 1222.BUILDING PERMIT: 18010-40000-03433	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36401	14041-10000-20983	1660 W ANAHEIM ST unit 120	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	33.77884	-118.29327	Installing a new 5500 motor along with a captive transformers and starter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36402	15041-10000-42870	749 S BROADWAY basement-1 floor	90014	14	127-5A209  96	5144014028	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	05/03/2017 12:00:00 AM		Issued	05/03/2017 12:00:00 AM	ADDRESS	34.04418	-118.25458	Full plan check for a commecial site (4 story building). Scope of work being done on first and second floor. Newly connected load is greater than 400 A. Total Sq ft = 22985	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36403	14041-10000-16541	1229 N MCCADDEN PL	90038	4	144B185   208	5532005040	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.09365	-118.33758	permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A load. ADDITION OF 2ND FLOOR CLASSROOMS TO SOUTH BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36404	10041-10000-00084	969 W COLORADO BLVD	90041	14	162A231    82	5709001001	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Closed	01/11/2011 12:00:00 AM	ADDRESS	34.13862	-118.18682	Two story new fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36405	16041-20001-13694	5144 N LANKERSHIM BLVD	91601	2	171B173   725	2353005016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.16426	-118.37406	01/18/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to theater. Total lighting area = 3,045 sq. ft.Note: Building permit has been pulled under 16016-20000-00252*****Previous Work Description*****New power receptacles, new branch circuits, and restrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36406	14041-20000-28119	201 N FIGUEROA ST 4TH FLOOR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING LIGHTING FIXTURES TO RECEPTION SPACE ON THE FOURTH FLOOR.  730SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36407	19041-10000-20692	3740 N CAHUENGA BLVD	91604	4	159B177    26	2425001042	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.13607	-118.36198	FULL PLAN CHECK FOR POWER AND ENERGY FOR INTERIOR TI. (2 FLOORS)NEW NON-BEARING PARTITON WALLS WITH NEW FINISHES. TOTAL NEW CONNECTED LOAD>400A WITH A TOTAL AFFECTED AREA = 10,121 SFBUILDING PERMIT: 19016-10000-15942	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36408	12041-10001-10024	504 S HARBOR BLVD	90731	15	015B201   221	7440030***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	33.74047	-118.27853	PLAN CHECK FOR REVISION DELTA A TO APPROVED PLANS. CHANGES CONSIST OF PROVIDING NEW 25KVA TRANSFORMER, PANELS, AND UPDATING NOTES ON PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36409	10041-10000-22259	1233 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.05214	-118.22647	Solar voltaic system installed on the roof of the building.  Consists of  8 modules,  8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36410	16041-10000-09376	2626 N ZORADA DR	90046	4	153B177    25	5569020014	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.11904	-118.36226	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (58) SUNPOWER MODULES AND (2) SMA SUNNYBOY INVERTERS AT 7KW. TOTAL SYSTEM SIZE 14KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36411	14041-10000-12579	828 S WALL ST STE B	90014	14	126A211   249	5145010030	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.03938	-118.25088	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 4621 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36412	15041-20000-03495	7619 W 85TH ST	90293	11	096B157   458	4114023012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	33.9607	-118.43094	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 10.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36413	17041-10000-03508	10430 N SEPULVEDA BLVD	91345	7	207B145   770	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.26014	-118.46701	PC FOR FA SYSTEM FOR CORE AND SHELL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36414	16041-10000-13008	10352 N GOTHIC AVE	91344	12	204B137   137	2679024026	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.25905	-118.48874	PV1, rooftop solar installation 11kW AC.   (35) SPR327NE-WHT-D     (1) SB6000TL      (1) SB5000TL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36415	19041-20001-08884	5178 N MECCA AVE	91356	3	171B125   412	2161019003	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.16516	-118.53735	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 19KW AC. SCOPE OF WORK INCLUDES (78) PANASONICE PV MODULES WITH P400 OPTIMIZERS, (1) 125A AC LOAD CENTER, (1) 5KW TRANSFORMER, (1) 5KW RESU10H LG CHEM BATTERY, (1) SE7600H INVERTER, (1) SE7600A INVERTER,  AND (1) SE3800H INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36416	18041-10000-38069	7257 W MELROSE AVE	90046	5	141B181   543	5525012011	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM			PC Approved	10/05/2018 12:00:00 AM	ADDRESS	34.08364	-118.34773	Energy plan check  for an  existing restaurant TI. Scope includes new lighting and equipment with a total area of 1014-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36417	11041-10000-16267	825 S BLOOM WALK 3rd floor	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	PIN	34.02192429	-118.28551249	TI IN AN EXISTING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36418	14041-10002-18516	8311 W BEVERLY BLVD	90048	5	138B173   397	5514009026	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.07623	-118.37043	Title 24 plan check only.  Total area = 1,440 sq. ft.Changes made to approved set.  Lighting fixtures removed and location of switches changed.  Use permit on master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36419	19041-10000-06714	3785 W WILSHIRE BLVD SUITE 104	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	10/06/2020 12:00:00 AM	ADDRESS	34.06187	-118.30858	FULL PC PWR AND T-24 TO A CHANGE OF USE FROM RESTAURANT TO RETAIL/MARKET, PROPOSED OF TENANT IMPROVEMENT FOR 7-ELEVEN  CONVENIENCE RETAIL 208/120V, 400A. AREA SCOPE IS 2689 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36420	16041-10000-39157	6200 W WILSHIRE BLVD #1010	90048	5	135B177   512	5088015021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.06295	-118.36347	Plan check for Title 24 only in exising highrise Suite # 1010 T.I. Total area: 1,162 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36421	18041-20000-26677	16534 W GREENLEAF ST	91436	5	168B137   511	2284005012	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.15575	-118.49345	Plan check for PV roof mounted system addition to existing system. System addtion size: 5.2KW with 6 modules. Total KW new plus existing is 11.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36422	12041-10000-24584	22544 W MACFARLANE DR	91364	3	171B097   900	2075023024	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.16244	-118.61805	PV1 - PLAN CHECK 4.8KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING SOLAREDGE TRANSFORMERLESS INVERTER AND POWER OPTIMIZER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36423	18041-10000-34692	2305 S SANTA FE AVE	90058	14	117A217    15	5167008033	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.01676	-118.23059	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36424	14041-20001-05411	7422 N DEMPSEY AVE	91406	6	186B141   437	2206027008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.20546	-118.47596	CHNAGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA - A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36425	17041-20000-04645	14216 W GILMORE ST unit 5	91401	6	180B153   960	2237020009	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.18753	-118.4429	pv2install roof mounted pv system sized 2kw interconnected with msp.  This is system 5 of 5.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36426	12041-10000-22522	8813 S SEPULVEDA BLVD	90045	11	096B165   974	4122035029	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	33.9568	-118.39645	CHANGE OF USE FROM RETAIL TO A NEW CHASE BANK IN AN EXISTING TI SPACE; NEW INTERIOR WALL OPENINGS FOR NEW EXTERIOR WALK UP  ATMS; REPLACE EXISTING ROOFTOP AC UNITS WITH NEW ; NEW PRECAST CONCRETE VAULT AND CONCRETE SLAB; TI AREA 5030 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36427	13041-10001-24817	8739 N AZUL DR	91304	12	195A091    91	2017004019	RE40-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.22884	-118.64898	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY. TRANSFORMERLESS. SYSTEM SIZE: 11.5 KW. 46 MODULES. 1 STORY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36428	18041-10000-02067	20101 W VENTURA BLVD	91364	3	174B113   462	2166033010	C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.171	-118.57145	PC FOR POWER AND ENERGY FOR A NEW REASTAURANT (1-STORY). SCOPE INCLUDES NEW 1200AMP SEERVICE, 5 NEW SUBPANELS, LIGHTING, RECEPTICALS AND EQUIPMENT.TOTAL AFFECTED AREA IS 39515 SQ.FTB# 18010-10000-00165	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36429	10041-10000-22828	2233 E CESAR E CHAVEZ AVE	90033	14	129A223   232	5175011027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2036.00, 2044.20	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	05/22/2012 12:00:00 AM	ADDRESS	34.04752	-118.20903	New Walgreens Store.  Plan Check is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36430	18041-10000-09392	17383 W SUNSET BLVD B280	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Approved	03/30/2018 12:00:00 AM	ADDRESS	34.03917	-118.55529	PC for power and energy for change of use from office to Medical office. Installing new panel, lights, receptacles and equipment. Total area 2100sqft. B# 18016-10000-06099.B: TENANT IMPROVEMENT TO MEDICAL OFFICE BUILDING (~2127 SF).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36431	14041-20000-09841	19114 W FRANKFORT ST	91324	12	192B121   777	2784019011	R1-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.22102	-118.54964	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL TRANSFORMERLESS INVERTER SYSTEM FOR SINGLE FAMILY DWELLINGS. STANDARD PLAN. SYSTEM SIZE: 3KW.(12) CANADIAN SOLAR CS6P(1) POWER ONE AURORA PVI 3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36432	18041-10000-36386	20326 W DEVONSHIRE ST	91311	12	204B113   186	2741008002	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM			Corrections Issued	09/26/2018 12:00:00 AM	ADDRESS	34.25709	-118.5762	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 26 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER. TOTAL SYSTEM SIZE 7.8KW DC /7.6KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36433	10041-10001-11236	10201 W PICO BLVD BLDG 99	90035	5	129B161  1442	4315019012	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Approved	12/22/2010 12:00:00 AM	PIN	34.05182951	-118.41257696	REVISED SINGLE LINE DIAGRAM TO SHOW AC/DC GROUNDING ELECTRODE SYSTEM AND TO SHOW REVISED DRAWING OF THE POINT OF CONNECTIONINSTALLATION OF A ROOF-MOUNTED 161 KW PHOTOVOLTAIC SYSTEM;  SYSTEM CONSISTS OF 4 ARRAYS MOUNTED ON THE ROOF OF THE CRAFTS BUILDING ON THE FOX STUDIO LOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36434	16041-10000-17389	1755 N ARGYLE AVE	90028	13	148-5A189   5	5546030029	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.1035	-118.32546	PC FOR POWER AND ENERGY .NEW 18-STORY 114 UNIT APARTMENT WITH GARAGE WITH NEW 480-277 V 3PH 4 WIRE 2500A  SERVICE. ALSO, ADDING NEW LOAD EQUIPMENT FOR EACH UNIT, INCLUDING 16 TYP UNITS AND TOTAL AREA 134070 SQFT. BUILDING PERMIT #15010-10000-04187	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36435	19041-10000-48001	1210 N PIEDRA MORADA DR	90272	11	135B117    87	4431032015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	05/26/2020 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.06838	-118.55159	FEES ARE 0$ DUE TO AB1414 & SB1222[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 35  (LG ELECTRONICS LG360QC1-A5) MODULES, 35  (SOLAREDGE P370) OPTIMIZERS, 1 (SE7600A-USS) CENTRAL INVERTER, 1 (LG CHEM RESU) BATTERY, CONNECTED TO AN UPGRADED 225A PANEL. SYSTEM SIZE IS 12.60KW DC & 7.60KW AC. *MAIN PANEL UPGRADE UNDER SEPERATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36436	17041-20000-46142	18951 W KINBRACE ST	91326	12	219B121    69	2820003032	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.29652	-118.54708	PV1.  Install 5.1 kW roof mounted grid tied PV system.  (18) modules with 5 kW rated string inverter.  Center-fed panel connection.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36437	15041-20000-30478	1025 W 190TH ST	90248	15	060B197   535	7351029020	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	33.85848	-118.29375	Title 24 plan check only.  Total area = 2,237 sq. ft.    T.I to existing office space.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36438	14041-20000-30006	17100 W LABRADOR ST	91325	12	201B133   154	2692012020	A2-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.24973	-118.50513	PERMIT $0.00 BY STATE SENATE BILL N0. 1222PV1Install roof-mounted solar array on SFD, interconnect with a 200A bus of a 400A split main panel.Derating main breaker.System size: 12.5kW (5+7.5). Grounded system.53 275W pv modules across 5 strings (3 strings of 11 on 7.5kW inv, 2 strings of 10 on 5kW inv).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36439	17041-20000-29363	22828 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.18625	-118.62435	Plan check for energy only. TI to existing bank. New lighting (incl. emergency). 4,030sqft. ( REPLAN CHECK DUE TO LOST PLANS.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36440	15041-20000-16951	9859 N SAN FERNANDO ROAD BLDG A	91331	7	201B165    89	2624019013	M2-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.24923	-118.40471	PLANCHECK FOR POWER AND ENERGY FOR   2 SEPERATE MACHINE SHOP BUILDINGS AND INSTALLATION OF A PANEL ON 3RD BUILDING .  [BUILDING A : 6977 SQFT]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36441	18041-10000-18532	15350 W OXNARD ST BLDG C	91411	4	177B145   462	2243001031	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	09/13/2020 12:00:00 AM		Permit Finaled	07/08/2021 12:00:00 AM	ADDRESS	34.17919	-118.46783	"** 2 of 2:  one set of plan for both Build. B & C **FULL PLAN CHECK FOR NEW THREE STORY BUILDING WITH ASSOCIATED SITE WORK (PARKING, LANDSCAPING, LIGHITING) SELF-STORAGE BUILDING ""C"". TOTAL AREA 149,046 SQ.FT (INDOOR + OUTDOOR SITE)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36442	15041-10000-16210	3905 W 6TH ST	90020	10	135B193   861	5503019010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.06364	-118.30812	REMODELING THE SUSHI ONE  RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36443	15041-20000-08091	8931 N MCLENNAN AVE	91343	12	195B133   158	2688026036	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.23301	-118.50092	PV1. ROOFMOUNTED. SYSTEM SIZE: 11KW AC. CENTRAL INVERTERS. NON STANDARD PLAN.(34) SUNPOWER E20-327(1) POWER ONE PV-6000(1) POWER ONE PV-5000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36444	15041-10000-24618	6201 W HOLLYWOOD BLVD	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC FOR POWER AND ENERGY. FIRST TIME TENANT, DUNKIN DOUNUT. 832 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36445	16041-20000-03725	9301 N TAMPA AVE #22	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is a tenant space with an existing mall. Project scope is a tenant improvement. Total lighting area = 4,309 sq. ft.Note: Building application has been created under 15016-20000-27568	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36446	13041-10001-26298	10006 N MONTGOMERY AVE	91343	12	204B141  1036	2669019019	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.25228	-118.48155	][][]EXPEDITED PER APPLICANT REQUEST [][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON-STANDARD PLAN WITH POWER OPTIMIZERS. SYSTEM SIZE IS 2.94KW DC WITH (12) MODULES: TRINA #TSM-245PA05.18(1)SOLAREDGE #SE3000-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36447	18041-30000-03552	355 S MUIRFIELD ROAD	90020	4	135B185   215	5505009007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.06741	-118.32894	Planc check for PV roof mounted system. Total system size: 19kW with 60 AC modules connected to 600A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36448	10041-20000-00503	8340 N VAN NUYS BLVD unit L	91402	6	192B149   292	2638022061	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	02/02/2010 12:00:00 AM		Permit Finaled	04/12/2010 12:00:00 AM	ADDRESS	34.22301	-118.44856	medical office  (contractor was told to have plan check, he pulled a permit from metro)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36449	18041-10001-22778	3717 W 64TH ST	90043	8	105B185   986	4004034037	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Approved	08/03/2018 12:00:00 AM	ADDRESS	33.98188	-118.3383	EXPEDITED FEESNEW ROOF TOP SOLAR SYSTEM TO A MULTI UNIT RESIDENTIAL BLDG, PER APPLICANT. (18) MODULES AND  (1) 5.2KW INVERTER. TOTAL SYSTEM SIZE IS 5.2KWAC/5.49KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36450	11041-10000-15221	10325 N ZELZAH AVE	91326	12	204B129   148	2731010027	(Q)C2-1VL, C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	ADDRESS	34.25805	-118.52352	T.I.  Existing 7-11.  Replacing existing light fixtures for retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36451	12041-10001-18269	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	34.0446	-118.21143	Modifications to approved set.  Changes to floor layout necessitating receptacle and lighting fixture relocations.  Original Work Description: PLAN CHECK FOR POWER AND ENERGY. NO SINGLE LINE NOR TITLE 24 CALCS NOR PANEL SCHEDULES INCLUDED. MEDICAL CLINIC. LOW RISE COMMERCIAL. CIRCUIT COUNTS PER APPLICANT. SUBJECT TO CHANGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36452	18041-10001-06931	13346 W BEAVER ST	91342	7	225B157   197	2510012029	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.31629	-118.42339	PC FOR REVISIONS TO APPROVED SET. SCOPE INCLUDES RELOCATION OF ELECTRICAL EQUIPMNET INCLUDING MSP, INVERTER AND DISCONNECT. THIS IS PLAN CHECK ONLY. PERMIT FEES PAID UNDER MASTER. Plan check for  PV roof mounted system. Total system size: 6.0kWac (1) 6.0 kW inverter and 28 modules connected to MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36453	19041-10000-33832	10856 N CARTWRIGHT DR	91311	12	210B113   257	2708030020	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/06/2019 12:00:00 AM	ADDRESS	34.26832	-118.56615	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 15.6KVA PV1 SYSTEM CONSISTING OF 3 INVERTERS(SOLIVIA 5.2 NA G4 TL) WITH 52 MODULES(315W,SC-B2 SERIES MODULES) CONNECTED TO EXISTING ENERGY STORAGE SYSTEM WITH 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36454	18041-10000-43492	2203 W VENICE BLVD #101A	90006	10	126B193   231	5074012034	[T][Q]C2-2-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.04372	-118.30623	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36455	16041-20000-38753	350 S GRAND AVE 45th Floor	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for energy only. TI to office on 45th floor of high rise office building. New lighting (incl. emergency) and receptacles. 7,119sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36456	10041-10000-15780	3500 W 6TH ST # 220	90005	10	135B197  1016	5502030016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	03/16/2011 12:00:00 AM	PIN	34.06344338	-118.29831795	TENANT IMPROVEMENT IN A CAFE SHOPPLAN CHK IS FO RTITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36457	18041-10000-44126	700 S FLOWER ST Suite 855	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Issued	11/19/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Design build: Energy plan check for an office T.I located on the 8th floor of a high rise building. Scope includes new lighting and equipment with a total area of 2,450-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36458	18041-10000-29494	5540 N OSTIN AVE	91367	3	174B089   473	2046013018	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.17165	-118.65129	PV1, NEW ROOF TOP SOLAR SYSTEM USING MICROINVERTERS. EQUIPMENT INCLUDES (15) MODULES AND (15) ENPHASE MICROINVERTERS. TOTAL SYSTEM SIZE IS 3.6KWAC / 4.5 KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36459	16041-10000-35578	22756 W VANOWEN ST	91307	12	180B097    38	2038020064	P-1VL, [Q]C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.19346	-118.62302	T-24, PC FOR ENERGY ONLY. TI TO AN EXISING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 22125 SQ. FT. (outdoors)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36460	18041-10000-00830	8334 W FOOTHILL BLVD	91040	7	204B189    47	2560008030	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.25954	-118.31465	Energy plan check for an office T.I. Scope includes new lighting and equipment. Total area is 18,285 SQ feet. Permit fees paid under 18041-10000-00047 - plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36461	19041-20000-53925	214 S RAMPART BLVD	90057	13	136-5A203 230	5155025012	R4-1	Central	Westlake	Echo Park	YES	2086.20	Electrical	Electrical	Apartment			12/31/2019 12:00:00 AM	02/08/2024 12:00:00 AM		Issued	02/08/2024 12:00:00 AM	ADDRESS	34.06785	-118.27757	INSTALL NEW 1200 AMP SINGLE PHASE SERVICE WITH PANEL, EQUIPMENTS, AND LIGHTS.NOTE PER BUILDING:(N) 5 STORY  24 UNIT APARTMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36462	15041-10000-42460	6007 S ST ANDREWS PL # 10	90047	8	105B193   569	6001018009	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	33.98484	-118.3116	Energy plan check for change of use T.I  from (E) warehouse to (N) food production of a space within an existing warehouse bldg. Total area is 3,318-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36463	11041-10001-16763	1456 S CLUB VIEW DR	90024	5	135B157   396	4327026008	R1-1	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.06405	-118.42193	Modification to approved set of drawings to add additional panels and use a different solar panel model.       <<<NEW 13.16 KW PV SYSTEM USING ENPHASE M215 MICRO-INVERTERS.  Variance is paid for.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36464	15041-20000-01994	8954 N MCLENNAN AVE	91343	12	195B133   112	2688026034	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.23353	-118.50079	PV1CENTRAL STRING INVERTER STANDARD PLAN STSEM SIZED 6.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36465	18041-10000-21015	641 W 40TH PL bldg 2 COM-CNTR	90037	9	115-5A201  92	5019025055	C2-1, R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.01065	-118.28546	Energy plan check for a community center T.I located in an apartment building. Scope includes new lighting and equipmnt with a total Title-24 area cover 8100-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36466	19041-30000-50002	20357 W TUBA ST	91311	12	204B113   224	2741008022	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.25639	-118.57697	PV1, NEW ROOFTOP MPUNTED SYSTEM, SYSTEM SIZE IS 11.4KWac/ 14.8KWdc. SCOPE OF WORK IS 57 MODULES (REC260PEZ) WITH OPTIMZERS (SEP400) LEADING TO A CNETRAL INVERTER (SE11.W), NO MPU.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36467	15041-10000-25634	731 S BROADWAY	90014	14	127-5A209  68	5144014032	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.04456	-118.25423	PC for power and energy. Scope includes new 800A 120/240V 3ph-4w service and distribution system for (E) 4-story commercial building. Total affected area is 19295 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36468	17041-20000-42975	308 S GLENROY AVE	90049	5	135B145    43	4366020007	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.07017	-118.46029	Note: $0.00 permit fee due to CA Senate Bill 1222pv1install roof mounted pv system sized 11kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36469	16041-10001-06364	1649 W 59TH PL	90047	8	105B193   192	6002009018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM			PC Approved	03/09/2016 12:00:00 AM	ADDRESS	33.98682	-118.30628	03/09/16CHANGES TO APPROVED SET OF PLANS. DOWNSIZE TO 9 MODULES. CHANGE IN MODULE TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36470	13041-20000-26170	20640 W CANTLAY ST	91306	3	186B109  1025	2113017009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.20213	-118.58339	PV1 TRANSFORMERLESS 8.25KW SYSTEM. 33 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36471	15041-10000-09975	2939 W LEEWARD AVE 1-80	90005	1	132B197   275	5077016030	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.05886	-118.28782	PC FOR METHEANE MITIGATION SYSTEM FOR 80 CONDOMINIUM BUILDING. 35 DEVICES AND 4 CONTROL PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36472	16041-10000-45475	964 N FARNAM ST	90042	1	154-5A223 335	5477022008	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.11655	-118.2096	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS  3.92KWdc / 3.0kWac.(14)MODULES-HANWHA Q-CELL Q.PLUS(14)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36473	13041-20000-34085	6856 N NEWCASTLE AVE	91335	3	183B129   850	2122008005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.1955	-118.52516	PV1 MICROINVERTER STANDARD PLAN. 16 PANELS AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36474	15041-10000-27504	1865 W BLAKE AVE	90039	13	147A213    82	5442008038	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.09832	-118.24348	NEW FA SYSTEM FOR A COMMERCIAL BUILDING WITH 20 FA DEVICES AND ONE FA PANEL AND ONE COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36475	10041-10000-06177	5333 W ZOO DR TAPIR	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	9800.09	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.14867	-118.28623	PLAN CHECK POWER AND ENERGY FOR TAPIR HOLDING AND EXHIBIT. BUILDING #0810-10000-02153.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36476	11041-20000-08295	1001 N VERMONT AVE	90029	13	144B197   961	5538022021	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.08964	-118.29193	TI TO AN EXISTING RESTAURANT.  T-24 OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36477	15041-10000-33338	1150 S OLIVE ST STE 2275	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE IN SUITE 2275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36478	17041-20000-24311	1180 S BEVERLY DR	90035	5	132A167   184	4330031026		West Los Angeles				2691.00	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.05581	-118.39554	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT . CHANGE OF USE FROM (E) OFFICE TO BANK AT FIRST FLOOR OF (E) OFFICE BUILDING. SEE COMMENTS.....BUILDING PERMIT # 17016-20000-18391	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36479	18041-30000-23892	1261 S STONER AVE 1-8	90025	11	129B145   887	4263008009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Apartment			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	01/30/2023 12:00:00 AM	ADDRESS	34.04711	-118.46065	Full PC for power and energy for a new 4 story 8 unit apartment, 4 story building with garage. Scope includes a new 800A 120/240 3 phase 4 wire service/distribution board, new panels, and new circuits. There are three typical panels for all 8 units. Total affected area is 11,485 Sq. ft. B#16010-30000-01721	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36480	17041-10000-20104	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.07666	-118.3805	****LOST SET***** SEE SUPP.  APPLICATION FOR PERMIT. Plan check for power only.  Installation of new distribution board, UPS, and two subpanels in existing Cedars Sinai building.  New HVAC and data rack loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36481	17041-10000-07285	4553 S GLENCOE AVE	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	33.98415	-118.43328	PC FOR T24 ONLY TO LOBBY AREA. TOTAL AREA  IS 1278 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36482	14041-20000-23239	7509 N WOODLEY AVE	91406	6	186B141   265	2205022002	[T][Q]MR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/26/2016 12:00:00 AM	ADDRESS	34.20687	-118.48387	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING 15 MODULES. SYSTEM IS USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36483	13041-20000-02432	819 S FLOWER ST	90017	9	129A207   199	5144021032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.04688	-118.26067	New Bar in an existing low-rise Hotel.  New panels, circuits, equipment.  Place of Assembly, Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36484	17041-10004-44422	5027 N MONTEZUMA ST	90042	1	151-5A225  52	5469009037	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.11101	-118.20559	CHANGES TO AN APPROVED SET TO REFLECT FIELD INSTALLATION. ALL CHANGES ARE CLOUDED UNDER DELTA 5. CHANGES INCLUDE RELOCATING THE INVERTER ON THE FLOOR PLANS AND ADDING AN AC DISCONNECT. *This is Plan check only, no additional permit is needed.NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-44422	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36485	14041-20000-17506	222 W 6TH ST suite 400	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	33.73887	-118.28305	Plan check for energy only. Tenant improvement on 4th floor of an existing high rise office building. New lighting (incl. emergency). 12,784 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36486	19041-10000-22715	6360 W FOOTHILL BLVD	91042	7	198B205    90	2572009020	(Q)C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1013.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.24265	-118.27006	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36487	18041-20001-14381	14200 W MULHOLLAND DR	90077	5	159B153   229	4379032011	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.13029	-118.44235	06-07-2018 Changes to an approved set of plan. Changes include remove Gateway relay. All changes has been clouded.Fees$0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36488	16041-20000-21228	10348 W DIAMOND ST LOT 15	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36489	18041-10000-25263	907 E 3RD ST	90013	14	129A215   276	5163006089	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.04611	-118.23458	TI IN AN EXISTING OUTDOOR PATIO OF MANUELA RESTAURANT,TITLE 24-ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36490	17041-10000-36523	11525 W CHANDLER BLVD	91601	2	171B169    59	2350010019	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.16877	-118.38311	PC for power and energy for new 60 unit four story apartment with one level of subterrenean parking. Installing new 2000A 120/208 service with switchboard, three distribution boards, 60 new panels.  Total area is 34344sqft indoor and 1622sqft outdoor. The site is on a methane buffer zone. B# 16010-20000-06398. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36491	12041-10000-18689	205 N SERRANO AVE	90004	4	138B193   614	5517010025	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	34.07554	-118.30686	Plan check for new roof mounted 3.8KW photovoltaic system (Aurora transformerless inverter).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36492	18041-20000-03479	2735 N LA CUESTA DR	90046	4	156B177   679	5570002001	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	10/20/2018 12:00:00 AM	ADDRESS	34.12104	-118.35657	Plan check for a PV1 roof-mounted PV system with battery storage. System size is 10.4 kWac and consists of (2) inverters, (35) modules, (2) load center, and (2) PowerWalls.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36493	14041-10000-15148	1421 S MAIN ST	90015	14	124-5A207 268	5133008004	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Closed	06/26/2014 12:00:00 AM	ADDRESS	34.03457	-118.26207	T24, REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 3022  SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36494	17041-10000-10398	14757 W KESWICK ST	91405	6	189B149   596	2210025019	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.21046	-118.45497	PC FOR 800A SERVICE UPGRADE TO COMMERCIAL SPACES. PROVIDING NEW SERVICE AND PANELS. REFEED EXISTING CIRCUITRY. THIS IS PC FOR POWER UPGRADES ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36495	18041-20000-34468	20702 W BEECH CIR #289	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	05/18/2019 12:00:00 AM	ADDRESS	34.29245	-118.58436	PV1.  Install 3.02 kW DC roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36496	13041-10000-29285	5620 N WILBUR AVE	91356	3	174B121   416	2160002042	(Q)CR-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM			PC Approved	10/21/2013 12:00:00 AM	ADDRESS	34.17273	-118.54456	Title 24 energy for a 4 story bldg, for canopy outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36497	12041-10001-30783	"12746 W JEFFERSON BLVD ""1"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	Change to approved set, changes include adding circuits, removing and adding lighting, and relocate some electrical devices.(((Plan check power and energy for Building 1. One story retail shell on top of common subterranean parking with Building 2, 3, and 4. Service supplying Building 1 and Building 2. Site located in methane zone. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36498	18041-10000-11864	1030 N SWARTHMORE AVE 4-105	90272	11	129B125   591	4423016007	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT(RESTAURANT) - SCOPE INCLUDES CONNECTING TO EXISTING DISTRIBUTION EQUPMENT RATED AT 800A 480/277V DISTRIBUTION BOARD WITH APPROX. 400A OF NEW CONNECTED LOAD. TOTAL AFFECTED AREA 2384 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36499	17041-10000-15564	1320 E 7TH ST 2ND FL	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	2ND FLOOR LIGHTING UPGRADES IN COMMON AREA. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36500	17041-10000-04696	6673 W FOOTHILL BLVD	91042	7	201A203    23	2570018002	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.24726	-118.27795	(E) MEDICAL OFFICE TI	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36501	16041-20001-39158	3230 S MAPLEWOOD AVE	90066	11	114B149   269	4247007007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.01052	-118.45201	expedite per applicantpv1install roof mounted pv system (ACM) sized 18.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36502	16041-10002-01027	801 S BROADWAY	90014	14	127-5A209 159	5144017028	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Closed	11/28/2023 12:00:00 AM	ADDRESS	34.04375	-118.25498	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED ON PLANS. UPDATED TITLE 24, SOME PORTIONS LIGHTING. UPDATED CIRCUITS FOR TELECOM ROOMS. PROVIDED UPDATED PANELS SCHEDULES AND SINGLE LINE LOADS. DISTRIBUTION REMAINS THE SAME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36503	16041-20000-11719	11500 W SAN VICENTE BLVD	90049	11	129B145   180	4265004***	C1.5-1VL, R4-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.05275	-118.46114	Plan check for a PV2 roof-mounted PV system. System size is 60 kWac and consists of (6) inverters, (190) modules, and (1) load center.Fee $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36504	18041-20001-17446	3333 E MISSION ROAD	90031	1	136-5A225 304	5211004019	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	PIN	34.06677133	-118.20531249	PLAN CHECK ONLY. CHANGES TO APPROVED SET. FROM FUSED TO NON FUSED AC DISCONNECT, ADDING 200A MAIN BREAKER TO LOAD CENTER, REVEALING ALL BUNDLED PV STRINGS 1-10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36505	18041-10000-24391	18021 W VENTURA BLVD	91316	5	171B125   350	2162005131	(Q)C2-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.16487	-118.52499	PLAN CHECH FOR POWER AND ENERGY FOR - TI OF EXISTING SHELL AND INTERIOR FOR A CAFE WITH DRIVE THRU. NEW CONNECTED LOAD >400A CONNECTING TO AN EXISTING 600A SERVICE USING 3 NEW 200A PANELS, TOTAL AFFECTED AREA = 2420 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36506	17041-30000-26718	14721 W CALIFA ST	91411	4	177A149   147	2244009026	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.1777	-118.45431	Plan check for Title 24 only T.I. office space. Total load less than 400A. Total area: 19,450 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36507	13041-20001-27583	17309 W RAYEN ST	91325	12	195B133   185	2768018006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2013 12:00:00 AM			Reviewed by Supervisor	10/16/2013 12:00:00 AM	ADDRESS	34.23232	-118.51173	EXPEDITE FEES ONLY.         <<<CONNECTION AHEAD OF MAIN TO BE APPROVED BY DWP.  New rooftop PV system for an existing single family residence.  System is Ungrounded and uses Power Optimizers.  PLAN CHECK ONLY.  (This is a change from a previously approved plan)>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36508	10041-20000-05614	10313 N SAN FERNANDO ROAD	91331	7	204B161   171	2623016001	C2-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Finaled	04/14/2011 12:00:00 AM	ADDRESS	34.2573	-118.41318	installing lighting and receptacle office area. this plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36509	17041-20000-36888	13037 W VICTORY BLVD	91606	2	180B161   790	2326017013	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	PIN	34.18809758	-118.4169914	CHANGE OF USE FROM (E) RETAIL TO BARBER SHOP (1,327 SQFT.).  PLANCHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36510	10041-10000-02341	12200 W OLYMPIC BLVD 3rd floor	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	06/14/2010 12:00:00 AM	ADDRESS	34.03195	-118.45506	TI - 3rd floor remodel for shopzilla.  NEW CIRCUITS AND OFFICES/ BREAK ROOM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36511	14041-20000-06010	731 E 9TH PL	90021	14	124-5A211 106	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.03593	-118.25008	NEW 800AMP SERVICE FOR CHANGES OF USE FROM WAREHOUSE TO MINISHOPPING CENTER FOR 6 RETAIL SPACES. BUILDING PERMIT#: 14014-10000-00248	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36512	19041-10000-02082	728 N SWEETZER AVE	90069	5	141B173   317	5528003203	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	12/14/2021 12:00:00 AM	ADDRESS	34.08452	-118.37016	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM CONTROL PANEL AND 258 DEVICES IN A NEW 5-STORY W/2 STORY OF UNDERGROUND PARKING, 49 UNITS LOW RISE APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36513	14041-20000-15285	6355 E CHURCH ST	90042	14	157-5A233 202	5483006007	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.12494	-118.17735	PV1.  Install 4 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with DC converters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36514	10041-10001-06245	610 E 7TH ST	90021	14	126A213   206	5146033036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM			PC Approved	06/10/2010 12:00:00 AM	ADDRESS	34.04022	-118.24654	REVISIONS TO APPROVED SET OF PLANS-REVISED SITE PLAN SHOWING SERVICE EQUIPMENT IS RELOCATED TO THE OPPOSITE  SIDE OF THE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36515	19041-10000-28998	6443 N TOPANGA CANYON BLVD	91303	3	180B101   691	2139002031	(WC)TOPANGA-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.18771	-118.60623	NEW FIRE ALARM SYSTEM WITH 28 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36516	12041-20001-28838	8150 W SUNSET BLVD	90046	4	147B173   327	5554007014	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.09781	-118.36653	(((5/30/2013: CHANGES MADE TO APPROVED SET OF PLANS. LIGHT FIXTURE L-13 IS NOT AN EMERGENCY FIXTURE. ADDED OCCUPANCY SENSOR IN THE CONFERENCE ROOM.)))T-24 lighting plan check for remodeled office spaces and conference room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36517	18041-10000-35612	865 S FIGUEROA ST 19TH FLR	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLAN CHECK FOR TITLE 24 ONLY FOR - T.I. NON-STRUCTURAL, DEMO, NEW PARTITIONS, CEILING PATCH. - TOTAL AFFECTED AREA = 494 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36518	12041-20000-09527	25 N OAKMONT DR Main-House	90049	11	135B137    64	4426022023	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2012 12:00:00 AM			PC Info Complete	03/20/2014 12:00:00 AM	ADDRESS	34.06938	-118.49075	New main house. guest house on a separate application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36519	18041-20001-34027	3430 W SUNSET BLVD	90026	13	144A203   261	5427026007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM			PC Approved	09/10/2018 12:00:00 AM	ADDRESS	34.08821	-118.27637	Plan check for Title 24 only in existing space T.I. Total area: 1099 sq ft. Plan check only. Permit pulled under Master application Number: 18041-90000-34027B#18016-10000-11758	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36520	19041-20000-06550	2439 N RIVERSIDE PL	90039	13	148-5A211 150	5440026008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM			Reviewed by Supervisor	03/06/2019 12:00:00 AM	ADDRESS	34.10129	-118.25338	NEW 7.315 KW DC/7.6 KW AC ROOFTOP PV SYSTEM AND ESS FOR EXISTING SFD, SCOPE OF WORK INCLUDES (1) 7.6KW AC SOLIVIA INVERTER, (308) TESLA PV MODULES, (1) NEW 125A LOAD CENTER, (1) NEW 200A LOAD CENTER, AND (1) 13.5 KW TESLA POWERWALL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36521	15041-20000-36514	519 S SPRING ST	90013	14	129A211   133	5149034005	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.04699	-118.2503	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36522	11041-20000-04338	6301 N OWENSMOUTH AVE 6TH FL	91367	3	177B105   123	2146029016	WC	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/09/2011 12:00:00 AM	ADDRESS	34.18467	-118.60176	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT 6TH FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36523	12041-10001-28787	9640 N SAGEBRUSH AVE	91311	12	201B101   880	2727002027	(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.24553	-118.61615	PV1:  Revision to the approved plan. Change the quantity of modules and size of the system to 13.20 KW . Roof mounted PV system for a single family residence.  Applicant is using the standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36524	15041-20001-31033	11942 W NEENACH ST	91352	6	195B169   508	2633017004	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	ADDRESS	34.22799	-118.39274	Expedite per applicant request[[[[[[[Plan check for PV roof mounted system. System size: 11.0kW with 37 modules and 2 inverters(5.0kW and 6.0kW)]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36525	13041-10000-11910	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	NEW TRAILERS (4,990 SQ. FT.) PROVIDE FIRE ALARM PANEL, SMOKE DETECTORS, AND AUDIBLE VISUALS AND DIALER FOR OFFSITE MONITORING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36526	14041-10000-12912	3871 S CIMARRON ST	90062	8	117B189  1156	5035021021	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Expired	06/08/2016 12:00:00 AM	ADDRESS	34.01536	-118.31619	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM WITH SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36527	17041-10000-00282	19053 W INGOMAR ST	91335	3	189B121   450	2104008023	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.21211	-118.54872	PC for energy only. Remove HID outdoor fixutres and replace with new LED fixtures. Total area: 22,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36528	10041-20000-12420	300 S GRAND AVE #320-350	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM			PC Info Complete	06/29/2010 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check T-24 Energy office general/emergency lighting spaces on the 3rd Floor (suite #320 & 350).  All lighting fixtures are existing. Work consist of relocating fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36529	13041-10007-26820	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			03/29/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	33.97574	-118.39042	03/26/16Changes to an approved set of plans, note changes on delta 13. Changes include switchgear names and panel names per DWP phasing. No new load or equipment. (((New 218-unit apartment building at Howard Hughes Center.  Power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36530	18041-20000-30696	17891 W RIDGEWAY ROAD	91344	12	216B129   336	2601032037	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.2851	-118.52415	PV1.  Install 7.50 kW DC/6.53 kW AC-CEC ground mounted grid tied PV system.  (25) modules with 6 kW rated string inverter.Note: Building permit has been issued under 18016-20000-28319	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36531	17041-20000-24067	6822 W HOLLYWOOD BLVD	90028	13	148-5A185 158	5548006017	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.10133	-118.33951	Plan check for energy only. TI to existing commercial retail. New lighting - 802sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36532	10041-10000-02737	12920 W RUNWAY ROAD	90094	11	102B157   315	4211021030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			02/25/2010 12:00:00 AM	07/02/2010 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	33.97447	-118.42112	PROPOSED 4-STORIES, 52-UNITS CONDOMINIUM W ONE LEVEL BASEMENT PARKING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36533	13041-10000-20678	10425 N COLUMBUS AVE	91345	7	204B145    26	2649019026	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.25989	-118.46519	PV1 4.32KW 240V MICROINV 2STORY. STD. ROOFMOUNT.[( 20) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36534	19041-10000-27804	962 N MALTMAN AVE	90026	13	142-5A203 120	5427022003	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.08598	-118.27953	[EPLAN] PLAN CHECK ONLY. DELTA D CHANGES TO APPROVED SET.  RELOCATING INVERTER'S LOCATION.  Original Plan check: 19041-10000-18786Delta A changes: relocating service panel and inverter was approved under 19041-10000-22116Delta B changes: reduce the inverter size from a 7600W to 6000W under 19041-10000-23236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36535	10041-10002-25778	333 E CULVER BLVD	90293	11	096B149   245	4116009013	[Q]C4-1D	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM			PC Approved	03/07/2011 12:00:00 AM	ADDRESS	33.96034	-118.44686	TITLE 24 ONLY PLAN CHECK AT COUNTER (SUP. TO PERMIT 10041-40000-25778)COMMERCIAL SINGLE STORY RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36536	17041-10002-16874	3421 E 14TH ST	90023	14	118-5A225 335	5190033004	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.01734	-118.206	Supplemental plan check only, permit is covered under maaster permit.  Revise the length of the primary and secondary tap of transformers, transformer still within sight of the Overcurrent protection. Revise short circuit study accordingly.  Changes are clouded on the plan.<<Power plan check.  Service upgrade to 3,000 amp 480/277 volts for industrial kitchen and warehouse building.  All loads to remain existing.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36537	16041-10000-45119	5001 W RODEO ROAD Gym & Pool	90018	10	120B181   948	5046013900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	05/06/2020 12:00:00 AM		Permit Finaled	05/27/2022 12:00:00 AM	PIN	34.02302534	-118.35149882	PC FOR POWER AND ENERGY. CONSTRUCTION OF INDOOR POOL WITH MEZZANIE. GYMANISUM BUILDING, CONNECTED BY A BRIDGE.INCLUDING TENNIS BLEACHERS. TOTAL AREA 45353 SQ FT.3 (E) SERVICES 1200 A, 800 AND 600 A.B # 16010-10000-03059	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36538	13041-10000-23415	5636 N TUJUNGA AVE	91601	2	174B173   775	2337039019	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			Corrections Issued	08/27/2013 12:00:00 AM	ADDRESS	34.1733	-118.37885	application to be terminated. refer to supplemtanl for new set of plans. TITLE 24 PLAN CHECK ONLY. SQFT 15630. EMERGERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 1 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36539	16041-10000-08120	11507 W ORUM ROAD	90049	5	144B145   192	4369002015	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.08943	-118.46356	NEW 600A MS, and 4 (N) panels with total connected load > 400A for a residential unit T.I;  PC for Electrical System only. Plan is under design-build.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36540	16041-10000-44974	10250 W SANTA MONICA BLVD # 1800	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1ST TENANT ""BOSE"" IN RETAIL SPACE #1800FULL PLAN REVIEW"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36541	14041-10000-06362	1317 S SANTEE ST	90015	14	124-5A209 200	5133017011	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.03474	-118.25874	T24, REMOVING HID LIGHT FIXTURES WITH NEW FLORESCENT FIXTURS. TOTAL AREA 624 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36542	11041-20001-27628	101 S THE GROVE DR Space K-10	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM			PC Approved	04/29/2012 12:00:00 AM	ADDRESS	34.07256	-118.35874	Changes from previously approved plans.  Majority of the changes are lighting with Tailor Method.  All changes are clouded and indicated by DELTA-2 as shown on plans.   Plan check for energy only.Note: Approved plan submitted for reference only.*****Tenant Improvement.  Existing retail space # K-10.  Banana Republic to occupy space.  Plan check is for power and energy.  NOTE TO PLAN CHECKER:  APPLICANT BROUGHT A PRE-CUT CHECK.  VERIFY FEES DURING PLAN CHECK PROCESS.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36543	14041-20001-24037	4929 N VAN NUYS BLVD	91403	4	169-5A151  49	2263026034	C1.5-1VL, P-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Expired	01/30/2017 12:00:00 AM	ADDRESS	34.16026	-118.4489	[[[1/6/14   SUPPLEMENTAL PLANCHECK FOR THE TRANSFORMER AND FEEDER TO THE MODULAR HYPERBARIC  BUILDING ]]]]200 AMP FOR MODULAR BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36544	12041-20000-11239	1745 N CAMINO PALMERO	90046	4	147B181    20	5550001***	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West		1899.01, 1941.00	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.10267	-118.35017	TI for common area of a 5 story condominium. Plan check for energy only. Existing emergency lightnig. 1455 sqft. Building is equipped with a generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36545	12041-20000-23344	7246 N HATILLO AVE	91306	3	186B113   806	2115010025	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	34.20259	-118.56522	Plan check for PV system for a SFD. 3 strings, 5.88 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36546	17041-10000-23757	12830 W RAYMER ST	91605	2	186B161   542	2324005024	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.20426	-118.4128	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 16500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36547	11041-20000-03962	2424 E OLYMPIC BLVD	90021	14	121-5A217 390	5168002800	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.02545	-118.22917	New additional 2000 A service.  Filed a variance to have 2 services to a building.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36548	16041-30000-10007	13430 W CHALON ROAD	90049	11	138B133   369	4492003001	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.07323	-118.50032	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 13.750 kWac.  Microinverter system. no fees due to senate 1222. mz	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36549	19041-20000-41375	11873 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	02/03/2023 12:00:00 AM	ADDRESS	34.28587	-118.38988	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36550	11041-10000-08139	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	09/29/2011 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	Installing new 480V feeders, panelboards & circuits for an oil recovery unit (Acid plant, unit# 141).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36551	16041-10000-17504	1840 S CENTURY PARK EAST 16TH	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI -ON EXISTING OFFICE BUILD.  AT 16TH FLOOR.  NEW CONNECTED LOAD LESS THAN 400A, PC FOR T-24 ONLY. TOTAL AREA: 15,128 SQ.FT.B# B16LA06494	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36552	13041-10000-36081	928 S BROADWAY	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			12/27/2013 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.04154	-118.25658	pc for power and energy. generator installed. methane zone13010-10000-02211: PROPOSED 9-STORY TYPE I  AND TYPE III-A  APARTMENTS OVER TYPE I GARAGE, RETAIL AND RESIDENTIAL (2 LEVELS ABOVE GRADE AND 4 BASEMENT LEVELS)PDPP   1 of  2 (70% w/ complete architactural, zoning, ADA, Green Building Plan Check.  NO Structural) Building Fire/Life Safety P.C.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36553	13041-20000-09068	5902 N PENFIELD AVE	91367	3	177B113   233	2153004015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.17804	-118.56982	SOLAR SINGLE FAMILY 19.04 KW. 400A panelupgrade (no change to service size) has been added to permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36554	11041-20000-21476	17401 W VENTURA BLVD	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/25/2011 12:00:00 AM	ADDRESS	34.16136	-118.51189	T.I.  Change of use from retail to office.  Weight Watchers to occupy space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36555	14041-20000-24601	11593 W KLING ST	91602	2	168B169   663	2354016040	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2014 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.1559	-118.38525	Change of module layout on roof only. Original permit pulled under permit #14041-20000-17533	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36556	17041-20000-02365	6712 W HOLLYWOOD BLVD	90028	13	148-5A185 145	5547014033	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.10134	-118.33659	Addition of single light above concession stand with led ropein counter top.  plan check for energu only.  total square footage 184.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36557	13041-10000-01971	222 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Apartment			01/25/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.05621	-118.25318	Upgrading fire alarm system for 19 story apartment building. 2 panels and 681 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36558	13041-20000-12815	6420 W WILSHIRE BLVD 1600	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.06365	-118.36922	RENOVATION OF EXISTING OFFICES. TOTAL AREA 7660 SQ FT. SOME NEW FIXTURES, RELOCATION OF FIXTURES AND REPARTITION OF INTERIOR. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED UNDER THIS APPLICATION. WORK DONE IN SUITE 1600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36559	15041-20000-16850	6200 N JUMILLA AVE	91367	3	177B117   405	2153022021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.18275	-118.56347	PV1 SFD TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36560	16041-10000-08613	2853 E 6TH ST	90023	14	124-5A225 269	5185018012	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2043.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.0344	-118.20655	PV1 INSTALL 3.57 KW DC ROOF-MOUNTED SOLAR ARRAY FOR A SINGLE FAMILY HOME. (14) MODULES: HYUNDAI HIS-M255RG(1) INVERTER: ABB PVI-3.6-OUTD-S-US -A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36561	16041-10000-10410	2928 N IDELL ST	90065	1	144A219   313	5446007026	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.08802	-118.22198	PV1 SFD TOTAL SYSTEM SIZE 3KW AC. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36562	16041-10000-44954	9754 N DEERING AVE	91311	12	201B105   139	2746004004	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.24788	-118.59716	PC for energy only; Indoor + Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 107,400.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36563	12041-20000-27079	11310 W SHERMAN WAY BLDG #1	91605	2	183B173   112	2319001006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Info Complete	01/08/2013 12:00:00 AM	PIN	34.19989971	-118.37702755	Plan check for power only. 1200A service upgrade.   Reconnect existing panel boards, and equipment to new distribution board.  Convert old board to pull box.  BLDG #1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36564	17041-10000-29211	11150 W SANTA MONICA BLVD 1200	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI TO OFFICE SPACE IN HIGH RISE BUILDING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36565	13041-10000-11275	1260 S VETERAN AVE	90024	5	132B149   167	4324003020	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			05/01/2013 12:00:00 AM			PC Approved	05/01/2013 12:00:00 AM	ADDRESS	34.05654	-118.4465	tITLE 24 FOR CORRIDOORS OF AN EXISTING 3 STORY APARTMENT BLDG,  ALL EXIT SIGNS AND EMERGENY LIGHTING TO REMAIN EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36566	17041-10003-12440	1900 S WESTWOOD BLVD	90025	5	129B153   740	4321011027	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.04815	-118.43521	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES REMOVAL OF PHOTO CELL.THIS IS PLAN CHECK ONLY. ***************************************ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36567	19041-20000-43276	7939 N CANOGA AVE	91304	3	189B105   191	2110005014	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.06	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	11/03/2021 12:00:00 AM		Issued	11/03/2021 12:00:00 AM	ADDRESS	34.21451	-118.5977	PLAN CHECK FOR POWER, UPGRADED 4000 AMP 208Y SERVICE NO NEW LOAD ADDED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36568	11041-10000-06406	4733 W SUNSET BLVD	90027	13	147B197   604	5543012018	C2-CSA1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Info Complete	06/22/2011 12:00:00 AM	ADDRESS	34.09833	-118.29305	INSTALLING A NEW UPS AND UPS PANEL.  WORK ALREADY PERMITTED, PC ONLY.PER INSPECTOR:1 LOAD FROM E. BOARD MUST COMPLY WITH ARTICLE 7002 SEQUENCE FOR SECOND ATC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36569	14041-10000-26203	3150 W WILSHIRE BLVD SUITE H	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.06163	-118.29086	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. ATT DEALER STORE . SUITE H.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36570	12041-10000-03275	2500 S NAVY WAY	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	33.73363	-118.2408	installation of medium voltage substation to provide power to future rubber-tired gantry cranes at the Port of Los Angeles	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36571	09041-10002-07273	5557 E VALLEY BLVD	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Public Safety Only			04/15/2010 12:00:00 AM	04/15/2010 12:00:00 AM		Permit Finaled	09/08/2010 12:00:00 AM	ADDRESS	34.07723	-118.16241	Suppl. Plan Check and Permit for the changes to approved plans and additional devices to the Fire Life Safety System in the building #330  per Delta 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36572	11041-20000-21516	1990 S BUNDY DR	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	34.03419	-118.45559	T.I.  Remodel of the corridor on the 4th floor.  Plan check is energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36573	15041-20000-39126	23212 W SYLVAN ST	91367	3	177B093   166	2035022031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.18443	-118.63204	"""0$ permit fees due to senate bill 1222""PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.0KWac. (50) MODULES-KYOCERA #KU2656ZPA(2) INVERTER-ABB PVI-5000 & ABB PVI-6000(1) 125A SUBPANEL"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36574	18041-20000-38726	5101 N CALATRANA DR	91364	3	171B105  1127	2168015049	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.16127	-118.60255	Plan check for PV roof mounted system, system size: 11.5KW DC, 9.24KW AC with 35 PV modules 1 inverter(11.4kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36575	19041-20000-05904	4209 N WOODMAN AVE	91423	4	165B157   841	2266021018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.14674	-118.43077	PC FOR ADDITION TO PV SYSTEM, ADDITION OF 3.78KW AC TO EXISTING 7KW AC SFD ROOF TOP PV SYSTEM WITH ESS. SCOPE OF WORK INCLUDES (1) 225A SERVICE PANEL UPGRADE, (1) 100A SUB PANEL, (12) PANASONIC 330W MODULES, AND (12) ENPHASE ENERGY IQ7X MICRO INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36576	19041-30000-06411	350 S GRAND AVE 15th fl	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only. Project site is a part of the 15th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 13,335 sq. ft.Note: Building permit has been issued under 18016-10001-34308	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36577	16041-30000-36010	4464 N VISTA DEL MONTE AVE	91403	4	168A151   273	2265011015	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Apartment			10/11/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.15299	-118.44972	Plan check for power and Title 24.  New 3 story 8 unit apartment building.  New 800 amp service @ 120/240 volts 3 phase 4 wire. Total common area = 6908 sq. ft.  Fire alarm variance has NOT been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36578	18041-30000-09082	313 N FIGUEROA ST suite 313	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	33.77231	-118.27886	Plan check for Title 24 only in existing space office and warehouse T.I. Total area: 6830 sq ft.B#17016-10000-30574	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36579	15041-20000-08361	10960 W WILSHIRE BLVD 9th floor	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check for Title 24 only. Project scope is a tenant improvement to a suite on the 9th floor of a high-rise building. Total lighting area = 1,718 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36580	17041-30000-39300	7300 WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Closed	03/20/2019 12:00:00 AM	ADDRESS	33.93972	-118.42295	Plan check for power only install medium voltage(1200A  at 5KV) distribution, re-arange temp switch gear. LAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36581	16041-20000-07636	11225 W ALLEGHENY ST	91352	7	201B173   170	2538023013	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.24962	-118.37624	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (30) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36582	16041-10000-45587	10250 W SANTA MONICA BLVD # 1915	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""RM WILLIAMS"" Ste. 1915.  Install new panels and its circuits, lights and receptacles. Total effected area: 1572 sq.ft. ."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36583	15041-10000-00452	2669 N GRIFFIN AVE	90031	1	139-5A223  23	5206005018	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			01/07/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Issued	03/04/2015 12:00:00 AM	ADDRESS	34.07847	-118.21203	Plan check for PV System size: 128.21kW(STC) with 1 inverter(100kW) and 440 module and 2 combiner boxs. Service size: 1000A, 120/240V 3PH/4W under separate permit.$0 permit fee is due to Senate Bill SB1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36584	14041-10000-32975	8559 W EDWIN DR	90046	4	156B169   341	5565044010	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.12115	-118.38741	Fee is $0.00 due to senate bill 1222.  (PV1.  Install 20 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36585	12041-10000-06310	1526 W PALOS VERDES DR NORTH BLDG O	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77934	-118.30441	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building O. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36586	14041-10001-28269	685 S NEW HAMPSHIRE AVE 1-177	90005	10	132B197   143	5094008041	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			11/20/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.06041	-118.29315	((11-20-2015: CHANGES MADE TO APPROVED SET. ADDED DETAIL FOR JBOX WIRING IN UNITS))NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36587	11041-10000-22849	3974 W WILSHIRE BLVD # 101	90010	10	132B189    81	5092030003	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	11/07/2011 12:00:00 AM		Permit Finaled	12/14/2011 12:00:00 AM	ADDRESS	34.06153	-118.31368	TENANT IMPROVEMENT IN A COFFEE SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36588	14041-20000-10119	12810 N MEADOWLARK AVE	91344	12	222B133   451	2602009003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.30331	-118.50857	pv1 single family dwelling. total; system size 9KW ac using multiple inverters. transformerless. nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36589	13041-10000-20220	1011 S FIGUEROA ST STE 102	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.04476	-118.26452	permit to be pulled at EPC counter only. pc for energy only. TI TO EXISTING RETAIL. LA LIVE Red Mango food shop.Inspector to verify if building emergency lighting is supplied by generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36590	18041-10001-41028	119 N HOBART BLVD	90004	10	138B193   841	5517011033	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.07435	-118.30564	PC ONLY, DELTA CHANGES TO APPROVED PLANS FOR CHANGING THE NUMBER OF PV PANEL FROM 30 TO 31 AND CHANGING THE SIZE OF THE PANELS FROM 300W TO 335W EACH. TOTAL PV SYSTEM IS RATED AT 10.385KW.   NO FEE PER AB1414.<<<Install New Rooftop PV system, 7.2 kW AC / 9kW DC. Install (30) modules and (30) IQ7 enphase micro inverter.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36591	18041-10002-19931	6761 S ARLINGTON AVE	90043	8	102B189   869	4008017030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM			PC Approved	07/24/2018 12:00:00 AM	ADDRESS	33.97655	-118.31885	VOID SUPP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36592	16041-20000-24968	14530 W RYAN ST	91342	7	225B149   141	2504004015	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Expired	08/23/2018 12:00:00 AM	ADDRESS	34.31553	-118.44874	Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP. 6kW ungrounded system.(26) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36593	14041-20001-16487	12659 N DORINA PL	91344	12	219B133    32	2602019008	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	34.30095	-118.50533	((EXPEDITE FEES))REDESIGN IN THE SYSTEM. NOW 6KW AC USING TRANSFORMERLESS INVERTER USING POWER OPTIMIZERS. 24 MODULES TOTAL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36594	17041-10000-44741	2121 S AVENUE OF THE STARS 32ND FLR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	PC FOR OFFICE TI IN A HIGH RISE BUILDING (32ND FLOOR).SCOPE INCLUDES NEW CIRCUITS, NEW PANEL,  LIGHTING AND EQUIPMENT.TOTAL AFFECTED AREA IS 14189 SQ FTB# 17016-10000-33446	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36595	10041-20000-16509	16945 W SHERMAN WAY	91406	6	183B133    24	2227003054	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	10/05/2010 12:00:00 AM	ADDRESS	34.20137	-118.50233	Revision to approved set. Change is feeding pv system to new 400 A panel and transfereing existing loads to the new panel.   Plan check was for pv system on 10041-20000-07646 for new 30KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36596	14041-10000-34631	1500 S BARRACUDA ST	90731	15	015B205    24	7440032***	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM				PC FOR POWER, RENEWING 3 METER 800 A THREE PHASE SERVICES. ADDRESS PER DWP 1500 BARRCUDA (A, B, AND C).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36597	16041-20000-41858	16643 W VANOWEN ST	91406	6	183B137   445	2225009015	R1-1, RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	10/21/2022 12:00:00 AM	ADDRESS	34.19404	-118.49571	Construction of (N) church building, type 1 construction with mezzanine.  Assembly occupancy, 290 proposed occupant load.  Plan check for power and energy.  Building permit filed under 16010-10000-05351.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36598	12041-10000-15931	3941 E GOODWIN AVE	90039	4	162B205   173	5593020012	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.13718	-118.27187	CONSTRUCTION OF A NEW 5452 SQ FT TIME WARNER CABLE UNMANNED CABLE HEADEND FACILITY TO CONSIST OF THE FOLLOWING: HEADEND ROOM, DC POWER ROOM, ELECTRICAL ROOM, LOBBY/QUIET ROOM, STORAGE ROOM AND ACCESSIBLE UNISEX TOILET <SEE COMMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36599	17041-20000-44710	7517 N CLEON AVE	91352	2	186B173   445	2410001009	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Issued	12/26/2017 12:00:00 AM	ADDRESS	34.20713	-118.36827	Plan check for solar pv system w/roof-mounted array for SFD.3.91kW ungrounded system. (17) EnPhase IQ6 microinverters.(17) 275W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36600	19041-10000-37184	601 W WILSHIRE BLVD	90017	14	129A209    76	5144005021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM			PC Info Complete	09/18/2019 12:00:00 AM	ADDRESS	34.04817	-118.25603	ENERGY PC ONLY FOR  PROPOSED CHANGE OF USE OF PORTION OF EXISTING OFFICE BUILDING FROM OFFICE TO RESTAURANT ON THE GROUND FLOOR. AREA OF SCOPE (2,230)Sq.Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36601	15041-10001-06965	15350 W SHERMAN WAY	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	34.20099	-118.46808	Revisions to approved set.  Changes to workstation controlled receptacle control scheme.  No other changes per applicant.  (((Title 24 plan check only.  Total area = 9,310 sq. ft.T.I. to existing low rise office space.  New lighting and recepticles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36602	19041-10000-24681	12160 W SHERMAN WAY	91605	2	183B165    72	2321001013	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.20073	-118.39833	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36603	14041-20001-02951	11554 N HUNNEWELL AVE	91342	7	213B165   419	2531022034	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM			Reviewed by Supervisor	02/12/2014 12:00:00 AM	ADDRESS	34.28035	-118.39682	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36604	19041-10000-30781	2437 W PICO BLVD	90006	1	129B197  1057	5076019024	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.04743	-118.29011	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36605	18041-10000-15175	1546 N ARGYLE AVE	90028	13	148-5A189 309	5546026022	[Q]C4-1VL-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.09951	-118.32503	REMOVE EXISTING HID FIXTURES AND REPLACE THEM WITH NEW LED FIXTURES. TITLE 24-ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36606	13041-10000-23179	14911 W CALIFA ST	91411	4	177A149   143	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.17768	-118.45793	PC FOR POWER/ENERGY. NEW 3 STORY PARKING STRUCTURE.not methane. green compliance.NEW 3-LEVEL PARKING STRUCTURE SERVING (E) OFFICE GLDG, 360 PARKING SPACES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36607	16041-10000-45540	9361 N CANOGA AVE	91311	12	198B105    68	2746014038	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.24067	-118.59779	Title 24 plan check.  Scope includes removing HID fixtures and replace with new LED fixtures for an existing commercial building(interior and exterior lighting). Total affected area is 109530 Sq. Ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36608	16041-20001-11986	16836 W DEVONSHIRE ST	91344	12	204B133   221	2685002041	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM			PC Approved	08/09/2016 12:00:00 AM	ADDRESS	34.25731	-118.49947	Plan check for power and energy. Project site is an existing building. Project scope is a change of use from retail to restaurant. Total lighting area = 4,245 sq. ft.Note: Building application as been created under 15016-10000-25949	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36609	19041-20000-41411	950 E 3RD ST STE 2B	90013	14	127-5A217 112	5163016017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Info Complete	11/07/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	Distribution, power, and lighting for first time tenant using (E) 4000A 480Y/277V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36610	11041-10001-14171	8480 W BEVERLY BLVD BLDG A	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.07577	-118.37599	Plan check only. Delta 2 revision.  Changes are adding notes for rewiring house panel ckts to tenant panel, added jboxes, empty conduit for low voltage wiring, note for 2000AT on 3000AF main breaker, and remove Marshall loads from MSD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36611	10041-10000-22262	237 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04974	-118.22713	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36612	18041-10001-34871	1640 S SEPULVEDA BLVD #120	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Approved	11/07/2018 12:00:00 AM	ADDRESS	34.04838	-118.44468	SUPPLEMENTAL FOR CHANGES TO APPROVED SET, CHANGE OF 2 LIGHT FIXTURES TO 1 DIFFERENT LIGHT FIXTURES. PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER 18041-10000-34871BUILDING PERMIT #18016-10000-24885	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36613	17041-20001-28288	1145 S GAYLEY AVE	90024	5	132B149   118	4363023033	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.05935	-118.44602	Revisions to approved set of plans.  SLD updated to reflect site conditions, revisions to connection points for new panels in distribution system, 400A HVAC subpanel split to (2) 200A subpanels, (3) new open office circuits.  (((Plan check for power and energy T.I. of level 1 and 2 in existing 3 story commercial building. Existing electrical service equipment panel board. Total area: 29,613 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36614	11041-20000-01566	649 W JEFFERSON BLVD	90007	8	120A201    58	5123009017	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Special Equipment			01/26/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Closed	01/31/2011 12:00:00 AM	ADDRESS	34.02274	-118.28142	Temp power for Sag event at the Shrine Auditorium Jan. 28- Jan 30.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36615	18041-10000-22723	11000 N SEPULVEDA BLVD	91345	7	210B145   466	2664005027	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.27006	-118.46694	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36616	15041-20001-32666	9001 N ZELZAH AVE	91325	12	195B129   129	2768003017	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	34.23392	-118.52323	Expedited per customer request.PV1. Instal roof mounted PV system sized 12 kW. Interconnected with main service panel.(48) Canadian Solar 255 Modules](2) Fronius Primo 6.0-1 Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36617	18041-20000-19573	9409 N OWENSMOUTH AVE	91311	12	198B105    65	2746014004	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.24126	-118.60205	Plan check for Title 24 Energy only in existing space T.I. office. Total area: 2665 sq ft.B#18016-20000-07505	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36618	17041-20001-14322	10315-10317 N ZELZAH AVE	91326	12	204B129   148	2731010027	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.25786	-118.52352	09/18/2017Changes to an approved set of plans, Changes include the addition of lights and T-24 revision under delta 2. ***PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT of retail space into dining room/restrooms (995 sf) and combine with (E)adjancent restaurant . 1770 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36619	10041-20000-12310	2052 S CENTRAL AVE	90011	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	ADDRESS	34.02271	-118.25191	TI FOR OFFICE SPACE. ENERGY AND POWER. FIRST TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36620	19041-10000-21563	8418 N KEOKUK AVE	91306	3	192B113   353	2781018007	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.22275	-118.57379	Plan check for a PV1 7.6kw AC / 11kW DC roofmounted system with (1) inverter, (2) strings, (39) modules and optimizers interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36621	16041-10006-15022	200-300 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA DCN-032. CHANGES INCLUDE ADDED SCOPE, MORE CIRCUITS AND PANELS TO FEED NEW ROOM BUILDOUTS AND REINSTATING SCOPE TO INCLUDE GENERATOR AND STANDBY SYSTEM. PERMIT WILL BE ISSUED UNDER THIS APPLICATION FOR ADDITIONAL ITEMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36622	18041-30000-09182	12746 W JEFFERSON BLVD 2-2120	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check for first time tenant retail space in mixed use building. Total area: 2,537 sq ft B#18016-30000-07473	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36623	18041-10000-46846	1736 S SEPULVEDA BLVD	90025	5	129B153   982	4323020036	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM			Corrections Issued	12/11/2018 12:00:00 AM	ADDRESS	34.04663	-118.44316	PLAN CHECK FOR ENERGY ONLY, CHANGE OF USE FROM ANIMAL HOSPITAL TO PRINTING SHOP  ON THE FIRST FLOOR. SCOPE OF WORK INCLUDES NEW CIRCUITS AND LIGHTING. TOTAL SQ. FT. 7400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36624	18041-10000-37130	7516 S OGELSBY AVE	90045	11	102B165   587	4110009024	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	33.97409	-118.39997	NEW ROOF MOUNTED 10.075 KW PV SYSTEM WITH 13.5KW ENERGY STORAGE ON A SINGLE FAMILY HOME. ALL RELOCATED LOADS SHALL BE AFCI PROTECTED, AND CONDUCTORS RATED AT 90 DEGREE C.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36625	15041-10002-10551	11922 S VERMONT AVE	90044	15	084B197   351	6088020013	C2-1L	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	33.92425	-118.29139	02/24/16Changes to an approved set of plans. All change made under delta 3. Changes include removing load equipment on panel 'NP1.' Note: permit paid under PCIS#15041-10002-10551((((**Supplemental Power PC and Permit: Install new Panel 225A.*Replacement of two incandolecent lights with florescent fixtures  in storage or prep room of Ralphs store, total area 290 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36626	18041-10000-34907	5503 E BALTIMORE ST	90042	1	154-5A227 196	5478009076	R2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.11765	-118.19793	NEW ROOF MOUNTED 5.61 KW PV SYSTEM WITH 19 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36627	13041-20000-22601	16417 W SAN JOSE ST	91344	12	207B137   795	2679016031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.26085	-118.48962	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.46 KW. 16 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36628	13041-10000-27971	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Public Safety Only			10/08/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Expired	11/17/2015 12:00:00 AM	ADDRESS	34.14436	-118.27496	new fire warning systempermit fee is in INSPECTION FEE PERIODnote that similar plans 13041-10000-24761 submitted by different engineer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36629	19041-30000-08901	1846 N CHEROKEE AVE	90028	13	150A185   294	5547004020	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	09/13/2023 12:00:00 AM	ADDRESS	34.10445	-118.33463	Plan check for a fire alarm system for a 5-story, 20-unit apartment building. System consists of (1) FACP and (75) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36630	18041-20000-24051	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.06725	-118.41704	Installation of (13) heat transfer mechanism units and event power panels in (E) golf course.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36631	15041-10000-15461	13350 W SHERMAN WAY A-B	91605	2	183B157    86	2328025026	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Issued	05/20/2015 12:00:00 AM	ADDRESS	34.20101	-118.42426	TI-24 IN (E) COMMERCIAL BUILDING. ALL PANELS ARE EXISTING ADDING NEW LIGHTING TO BUILDING 'A' AND 'B'. TOTAL SQ. FT. 1840. PC FOR ENERGY ONLY .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36632	15041-20001-42783	16470 W OLDHAM ST	91436	5	162B137    82	2293004002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM			PC Approved	12/29/2015 12:00:00 AM	ADDRESS	34.14306	-118.49189	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:14.28 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36633	15041-10001-13552	1355 W FLORENCE AVE	90044	8	102B197  1164	6014033030	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	33.97474	-118.2999	Supplemental PC only . T-24 for outdoor lighting at Jack in the Box 5323. Total area: 22,800 sq. ft. Permit under 15041-10000-13552.***REPLACING EXISTING EXTERIOR AND PARKING  LOT LIGHTS W/L.E.D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36634	14041-20000-19933	6320 N CANOGA AVE Suite 750	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check for energy only. New lighting (incl. emergency) and receptacles on 7th floor of existing high rise office building. 4,838sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36635	17041-20000-34773	7080 W MAYDOCK PL	91042	7	204B201   374	2565007073	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.25677	-118.2856	PV1.  Install roof mounted grid tied 6.9 kW PV system.  (30) modules with microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36636	17041-10001-03354	13213 W ROSE AVE	90066	11	114B149   484	4244004024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM			PC Approved	03/16/2017 12:00:00 AM	ADDRESS	34.00899	-118.45386	PC FOR PV SYSTEM WITH BATTERY STORAGE.  INVERTER SIZE 7.6KW AC USING TESLA POWER WALL. BACKFEED UTILITY WITH BACK UP LOAD CENTER INSTALLED AS WELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36637	16041-20000-12235	662 N SEPULVEDA BLVD 3rd Floor	90049	5	138B145    76	4368016068	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.07736	-118.4688	TI to (E) commercial office tenant space.  2,941 sq ft.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36638	15041-20001-26141	3660 S COLONIAL AVE	90066	11	114B153   996	4246009005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.00668	-118.43694	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (26) modules, and (26) power optimizers. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36639	17041-10000-35485	620 S BROADWAY	90014	14	129A211   228	5144002020	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.04603	-118.25236	T-24, PC for energy only. Change of use and tenant imporvement from existing restaurant to retail. Scope includes new lights and receptacles. Total affected area is 13316 Sq. Ft. 17016-40000-24031	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36640	14041-10002-29996	616 S NORMANDIE AVE	90005	10	135B197  1114	5502031011	R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			07/30/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Closed	01/14/2016 12:00:00 AM	ADDRESS	34.06287	-118.30017	Revisions to approved set.  (2) additional panels and motor loads, lighting plan and fixture schedule revisions.  Change to 3 phase panels for residential units.    (((Improvements to 16 story senior living apartment building.  Plan check for the addition of generator for fire pump and new lighting and power for redesigned 1st floor. Renovations to lighting for common area corridors above first floor.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36641	15041-10000-06970	616 N LA BREA AVE	90036	5	141B181   780	5525017005	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Closed	10/10/2019 12:00:00 AM	ADDRESS	34.08242	-118.34385	TI TO AN EXISTING COMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4075.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36642	15041-20000-24471	1000 W WILSHIRE BLVD 18th fl.	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	TI to existing commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 1,130.****Project located at 18th floor corridor and elevator lobby****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36643	13041-10001-29461	13111 W COMMUNITY ST	91352	6	192B161    41	2634029006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.22337	-118.41871	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36644	13041-20000-00172	8500 N BOTHWELL ROAD	91324	12	192B117   293	2783016031	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.22487	-118.56097	New 5.52KW rooftop mounted PV system for an existing single family residence.   System is ungrounded/transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36645	10041-10000-17935	2001 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			09/10/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	PIN	34.06587468	-118.19737837	Core and shell for 3 story office building. Plan check for power and energy. (Separate fire alarm variance paied)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36646	19041-20000-52313	19340 W RINALDI ST	91326	12	210B117    25	2822019012	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Closed	11/24/2020 12:00:00 AM	ADDRESS	34.27348	-118.55489	FIRE ALARM PLAN CHECK FOR NEW FIRE ALARM SYSTEM. (1) FIRE ALARM PANEL AND (42) FIRE ALARM DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36647	11041-20000-01012	2011 E ZONAL AVE 8th Floor	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	ADDRESS	34.06159	-118.20463	T.I. to existing building.  Install general lighting in office room 801B.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36648	16041-20000-20276	6616 N RANDI AVE	91303	3	180B101   365	2139023011	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.19044	-118.60689	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.7KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36649	13041-10000-26817	5900 W CENTER DR	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			10/15/2013 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	33.97559	-118.38853	New 327-unit apartment building at Howard Hughes Center.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36650	12041-20000-27334	350 S GRAND AVE	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for energy and emergency lighting. Lobby. 9340sqft. High-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36651	14041-20000-01963	13259 W TERRA BELLA ST	91331	7	204B157   618	2620019007	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.25598	-118.42186	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36652	13041-10000-06358	5938 N SATSUMA AVE	91601	4	177B173  1296	2415012034	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.17867	-118.36683	photovoltaic system for single family dwelling. total system size 4.59kw. using 20 modules. transformerless inverter. nonstandard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36653	18041-20001-41904	202 S OCEANO DR	90049	11	132B141   282	4404033014	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.05921	-118.47278	Expedited plan check fee. PV1.  Install 16.92 kW roof mounted grid tied PV system.  (47) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36654	14041-10000-05672	128 N ELLITA PL	90042	1	150A227    23	5468017008	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Expired	04/05/2016 12:00:00 AM	ADDRESS	34.10733	-118.19953	PV1. ROOF MOUNTED SOLAR SYSTEM.  TRANSFORMERLESS INVERTER. TWO STORY. SYSTEM SIZE: 1.5 KW DC.(6) TRINA SOLAR TSM-250(1) POWER ONE AURORA PV1-3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36655	15041-10000-22457	10418 W PENROSE ST	91352	7	195B177   247	2404002016	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.23206	-118.35781	Permit fee is 0.00 due to Senate bill 1222. PV1 roof-mounted system , installing (20) new modules, and Enphase M215 microinverters inadditon to an existing PV system. Total number of microinverter for the whole new system is (62) M215 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36656	11041-20000-15907	555 W 5TH ST 2nd floor	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	Ti in the second floor of Gas company (Restaurant) BLDG. EPC is for T24 & Emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36657	19041-10000-34379	817 N VINE ST	90038	13	141B185   173	5533030029	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	01/11/2022 12:00:00 AM	ADDRESS	34.0858	-118.32679	SCOPE OF WORK IS A TI IN AN EXISITNG COMMERCIAL BUILDING, SCOPE OF WORK INCLUDES ADDITION OFNEW  FIRE ALARM DEVICES (171)  TO AN EXISITNG FIRE ALARM SYSTEM. NOTE A RPS IS BEING INSTALLED AS WELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36658	12041-10000-22697	333 S HOPE ST	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	Ti in an office for banck of America. EPC is for T24 (13th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36659	10041-10000-17701	275 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	PIN	34.04979564	-118.22640016	Solar voltaic system installed on the roof of the building.  Consists of  9 modules,  9 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36660	12041-10000-10032	6037 N TOPANGA CANYON BLVD	91367	3	177B101   126	2146025003	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Closed	09/20/2012 12:00:00 AM	ADDRESS	34.18032	-118.60616	"CHANGE OF  USE FROM OFFICE TO REATIL  & ADD. ( 14'-8"" X 6'-0"": 88 S.F.) NEW ENTRANCE  &   TENANT IMPROVEMENTS TO AN (E) ( 9,430 S.F.) SINGLE STORY COMMERCIAL BUILDING & PARKING LOT RE-STRIPING"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36661	15041-20000-25093	10593 W WILKINS AVE	90024	5	132B157   621	4326022012	R1-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Expired	08/31/2017 12:00:00 AM	ADDRESS	34.05738	-118.43146	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter, and (9) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36662	16041-10002-20290	5822 S 3RD AVE	90043	8	108B189  1483	4005022006	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	33.98841	-118.32045	06/28/2016Changes to an approved set of plans note changes on delta 1. Changes include the relocation of pv equipment. (((PV1, rooftop solar instllation 2.5 kW AC system.   (10) SW275,   (10) M250 Enphase)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36663	16041-10004-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			05/03/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	CHANGES TO AN APPROVED PLAN SET. ADDITION OF SHOWER REMOTE VALVES TO TYPICAL UNITS D, F, AND H. CLOUDED DELTA 10 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36664	13041-10002-11394	7261 W TRANQUIL PL PV1	91042	7	198B197   208	2562020008	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2013 12:00:00 AM			PC Approved	06/28/2013 12:00:00 AM	ADDRESS	34.24102	-118.29064	Applicant submits for electrical plan check due to change of design from transformered inverters to transformerless.  {33 modules: Canadian Solar CS6P-250PX-BF} {Transformerless inverters: 2x Power-One PVI-3.6}Previous supplemental work description: SUPPLEMENTAL PERMIT FOR 6 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36665	16041-10001-01538	5850 N SEPULVEDA BLVD	91411	4	174B145    43	2243018028	C1.5-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			Not Ready to Issue	08/21/2017 12:00:00 AM	ADDRESS	34.17721	-118.46589	Plan check for power and energy for load greater than 400 amps.  Changes to approved set (original application was checked for Title 24 only).  TI to existing commercial building (PETCO).  Total sqft. 15,005. B#16016-40000-00116. Permit for this project was obtained under 16041-20000-01538.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36666	17041-20000-04331	2231 S BARRINGTON AVE	90064	11	123B149   480	4260012027	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Issued	10/26/2017 12:00:00 AM	ADDRESS	34.03337	-118.44727	Change of use fron retail to restaurant/office single story. Adding new 800amp distribution board connected to existing 1200amp board. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36667	18041-20000-17641	6115 W SUNSET BLVD	90028	13	147A189   234	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Issued	05/15/2018 12:00:00 AM	ADDRESS	34.09819	-118.32261	Tenant improvement to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36668	14041-10000-02599	2200-2212 W PICO BLVD	90006	1	129A201   236	5056008012	C2-1VL	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			01/29/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.04716	-118.28441	NEW 800A 120/240V, 1PH, 3WIRE, UNDERGROUND SERVICE. SCOPE OF WORK ALSO INCLUDES NEW FEEDERS.  NO NEW CIRCUITS ADDED PER ENGINEER. PNL 'A' WILL BE LEFT FOR FUTURE TENANTS.This upgrade of service to 800 amp onlyNOTE: NOT LOCATED IN METHANE ZONE PER ZIMAS; PLAN WILL SUBJECTED TO 2011 NEC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36669	16041-10001-45793	7157 WORLD WAY MSC-M/V	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM			Reviewed by Supervisor	05/15/2018 12:00:00 AM	PIN	33.94094587	-118.40577128	CHANGES TO APPROVED SET OF PLANS PLAN CHECK FOR POWER AND ENERGY - SCOPE INCLUDES ADDITION OF NEW PANELS AND CIRCUITS WITHIN MULTIPLE PANELS, AS WELL AS RELOCATION OF LIGHTING (PHOTOMETRICS)FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES  Adding new lighting, medium voltage power, and emergency power to LAX MSC utility equipment room Total area: 5285. b#16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36670	10041-20001-10187	6203 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/18/2010 12:00:00 AM			PC Approved	06/18/2010 12:00:00 AM	ADDRESS	34.18321	-118.60617	Revision to approved plan. Single line diagram was different than previously approved plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36671	14041-10000-16767	777 S FIGUEROA ST # 4250	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.04828	-118.26116	Tenant improvement in existing offices on the 42nd flplan chk is for title 24 and 1 em circuit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36672	14041-10000-29930	610 S BROADWAY	90014	14	129A211   192	5144002018	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.04624	-118.25211	New 400-Amp service (switchboard) replacement. under customer request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36673	19041-10000-35537	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	08/19/2020 12:00:00 AM		Permit Finaled	06/27/2021 12:00:00 AM	ADDRESS	34.14947	-118.43885	PLAN CHECK FOR INSTALLATION OF 4 x LEVEL II 150KW EV CHARGING STATIONS IN RALPHS PARKING LOT. SCOPE INCLUDES 1600A SWITCHBOARD AND 30KVA TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36674	13041-10000-02984	7307 S EL MANOR AVE	90045	11	102B165   324	4110010010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	33.97598	-118.3991	PHOOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. SINGLE STORY. 1.3KW. 6 PANELS. MICROINVERTER ENPHASE M215-60-2LL-S22. SOLAR PANEL SHARP ND-240QCJ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36675	14041-10000-25060	710 S LA BREA AVE	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.06164	-118.34397	NEW T.I.  TENANT IMPROVEMENT TO (E) RETAIL SPACE. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36676	15041-10000-03111	13002 W GARBER ST	91331	7	204B161    67	2623008005	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.25875	-118.41567	Installation of roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36677	19041-20000-18570	4411 S CENTRAL AVE	90011	9	112-5A209  91	5108028022	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	11/16/2020 12:00:00 AM	ADDRESS	34.00353	-118.25676	OSHPD 3. PLAN CHECK FOR TI/T24 FOR NEW OPTOMETRIST OFFICE IN EXISTING COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW 200A 240/120V 3P 4W SERVICE, NEW 200A PANEL, A 225A PANEL, AND A 125A PANEL. T24 INCLUDED TOTAL SQUARE FOOTAGE = 4,073SFB#18016-10000-00260	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36678	15041-20000-16309	5800 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.09728	-118.31693	Plan check for power only.  Installation of two new medium voltage step down transformers (2.4 kV - 208/120 V).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36679	19041-10000-51257	11249 N ALTA AVE Lot 43	91345	7	210B145   567	2664028004		North Valley				1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.27508	-118.46871	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 10 MODULES (HANWHA Q.PEAK BLK-G5315), 10 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)SYSTEM SIZE: 2.835 KW DC;  3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36680	11041-10000-20485	13020 W PACIFIC PROMENADE 1-72	90094	11	102B157   226	4211029***	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			09/26/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	ADDRESS	33.97287	-118.42296	T.I. to an existing retail area.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36681	19041-20000-42436	13406 N MANZANILLO LANE	91342	7	225B157  1055	2510026020	(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.31512	-118.42191	Plan check for PV roof mounted system, PV System size: 1.68KW with 7 PV Modules and 7 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36682	13041-10000-23390	3632 N FAWNDALE PL	91403	4	159B149    41	2275022018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.13625	-118.45469	PV1 10.464KWdc 240V XFMR(positive ground) INV. 2STORY. STD. ROOFMOUNT.[( 1) INV: SUNPOWER SPR-10001f][( 32) MOD: SUNPOWER spr-327ne-WHT-D]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36683	17041-20001-09876	12601 W PIERCE ST BLDG 4	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (building 4).4kW ungrounded system. (8) AP Systems YC500i microinverters. (16) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36684	14041-10000-28309	3650 E OLYMPIC BLVD	90023	14	118-5A227 227	5191024011	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.01861	-118.1992	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.PV2, INSTALL 343.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  RETAIL STORE(FOOD FOR LESS),  INTERACTION WITH THE MAIN PANEL. 66 STRINGS.(1347) MODULES: ZNSHINE ZXP6-60-255/P(11) INVERTERS:SOLAECTRIA PV1 28TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36685	14041-10000-17741	936 N BEAUDRY AVE	90012	1	136-5A213  91	5406026007	R3-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.06813	-118.24626	PC FOR POWER AND ENERGY. NEW 2-STORY, 9-UNIT APARTMENT BUILDING WITH BASEMENT PARKING GARAGE. TOTAL AREA (INDOOR = 6370 AND OUTDOOR= 2646) SQ FT.PLAN CHECKER VERIFY THE # OF BRANCH CIRCUITS AND DEVICES.BUILDING APP #: 12041-10000-02657.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36686	11041-10000-20674	1034-1042 E ELKGROVE AVE BLDG 17	90291	11	111B145   518	4243001035	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.00166	-118.45883	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36687	14041-20000-20770	6333 W 3RD ST #P11	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.07157	-118.36014	TI to (E) retail store tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36688	16041-10000-28708	18049 W MEDLEY DR	91316	5	165B125   270	2184033008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Issued	09/29/2016 12:00:00 AM	ADDRESS	34.14742	-118.52635	Plan check for PV roof mounted system. System size: 10kW with 2 inverters(5.0kW) with 28 modules connected to 400 A service Split Bus(200)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36689	10041-10000-10009	3101 N ARTESIAN ST	90031	1	142-5A221 658	5205010900	PF-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.08214	-118.21723	New PV system. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36690	16041-10000-22857	10210 N AMBOY AVE	91331	7	204B157   642	2646023022	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.25583	-118.42592	PV1 roof mounted solar system installation to a single family home. Installing a central inverter tated at 3.8 kw and 17 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36691	15041-10001-27116	12460 W OSPREY LANE 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	PV2 ROOF MOUNTED. TOTAL SYSTEM SIZE 1.84 KW ON COMMERCIAL 4-STORY BUILDING (BUILDING 8 UNIT 22) UNIT TWO (8) MODULES: SUNPOWER MODULES SPR-230NE-BLK-D(1) INVERTER PVI3.0 OUTD-S-US-A (POWER ONE) 240VACZONING CLEARANCES FOR UNIT 1,2, AND 3 INCLUDED.EXPEDITE PER APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36692	10041-20000-22049	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	03/23/2011 12:00:00 AM	ADDRESS	34.06307	-118.2	Plan check T24 energy general and emergency lighting for kitchen remodel at USC Child Care Center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36693	15041-10000-34602	11437 W HATTERAS ST	91601	2	174B169   239	2338014024	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			10/16/2015 12:00:00 AM			Reviewed by Supervisor	11/19/2015 12:00:00 AM	ADDRESS	34.17588	-118.38025	PLAN CHECK FOR POWER AND ENERGY FOR NEW 7 UNIT APARTMENT BUILDING. 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36694	17041-10000-02587	946 N SEWARD ST	90038	13	144B185   998	5533023026	(T)(Q)M1-2D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.08851	-118.33305	PC for outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Area: 14,615.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36695	18041-10000-27307	5959 N CANOGA AVE	91367	3	177B105    88	2146006018	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.17875	-118.59772	TI IN AN EXISTING BANK OF AMERICA 7,683. T-24 ENERGY ONLY.BULIDING PERMIT: 18016-10000-23241	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36696	18041-20000-11740	7401 N SHOUP AVE	91307	12	186B101   532	2022019023	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.20486	-118.61489	PC for FA system for charter school. Installing one FACP, annunciator and 95 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36697	16041-10000-30803	420 E 25TH ST	90011	9	120A207   126	5127011025	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.02397	-118.26418	PV1. Installation of a roof mounted solar system to a single family home. Installing a microinverter system with (35) Modules each rated at 215 watts for a total system size of 7.52KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36698	16041-20000-33590	6840 N DE CELIS PL 33	91406	6	183B137   536	2225001***	[T][Q]RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.19497	-118.4944	pv1install roof mounted pv system sized 3.8kw interconnected with msp.permit fees paid under application number 16041-90000-22228.this is plan check only.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36699	11041-10000-26376	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	04/12/2012 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	33.98645	-118.44148	PLAN CHECK POWER AND ENERGY FOR RELOCATION OF 800A SWITCHBOARD, ESCALATORS, AND OUTDOOR LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36700	18041-20000-40484	4660 W MELROSE AVE	90029	13	141B193   584	5521007036	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.20	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM	02/18/2021 12:00:00 AM		Permit Finaled	11/29/2022 12:00:00 AM	PIN	34.08337619	-118.30214316	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36701	17041-20000-29797	700 S FLOWER ST STE  550	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36702	16041-10000-17069	1900 S AVENUE OF THE STARS #24400	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM			PC Info Complete	05/27/2016 12:00:00 AM	ADDRESS	34.05979	-118.41671	OFFICE T.I. FOR SUITE 24400 (24TH FLOOR).  INSTALL NEW LIGHTS AND CONTROLLED RECEPTACLES. PC FOR T-24 ONLY. TOTAL AREA:  2,891 SQ. FTB# 16016-10000-11101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36703	14041-20000-15115	125 E DON ST	90744	15	039B205   735	7422001027	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	33.79849	-118.26287	PV1Microinverter standard plan. Install microinverter solar array on SFD. System size: 3.24kW.(15) Enphase 215 microinverters. (15) Sun Module SW250 pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36704	16041-20000-23957	15137 W FRED WAY	91405	6	186B145  1117	2209034006	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.2092	-118.46322	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36705	14041-10000-23574	5539 N RIVERTON AVE	91601	2	174B173  1109	2416014026	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.17108	-118.36581	(((( no fees due to senate bill 1222 m.z ))))   PV2. ROOFMOUNTED SOLAR SYSTEM. GROUNDED CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 100KW DC.(400) ECOSOLARGY 250 WATT MODULES(3) POWER ONE ABB 20KW INVERTERS.(1) POWER ONE ABB 27KW INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36706	16041-10001-30082	1908 N MONON ST	90027	4	150B201  1004	5433007026	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM			PC Approved	10/05/2016 12:00:00 AM	ADDRESS	34.10569	-118.27951	EXPEDITE FEESPV ROOF MOUNTEDPC FOR PV SYSTEM WITH BATTERY STORAGE. USING 17 MODULES OF AC PV MODULES. 6.1KW AC TOTAL. USING BATTERY STORAGE INVERTER SYSTEM. INSTALLING LOAD CENTER FOR OPTIONAL STANDBY LOADS. INSTALLING PV SUBPANEL FOR COMBINING AC MODULE CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36707	10041-20000-02144	6434 N WOODMAN AVE	91401	2	180B157   831	2329004027	R3-1, [Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM	06/17/2010 12:00:00 AM		Permit Finaled	11/17/2010 12:00:00 AM	ADDRESS	34.18764	-118.43105	T. I. WORK IN PRIVATE SCHOOL DOING OUT DOOR LIGHTING. THIS PLAN CHECK IS FOR ONLY FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36708	16041-20000-41478	11183 N HERRICK AVE	91331	7	210B161   298	2534027034	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Issued	11/23/2016 12:00:00 AM	ADDRESS	34.27307	-118.4171	PV1. ROOFMOUNTED SOLAR SYSTEM . SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36709	16041-20000-28646	223 W 8TH ST	90014	14	127-5A209 314	5144015***	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.04359	-118.25421	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR MOD'S HAIR DTLA. HIGH RISE. 657 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36710	16041-10000-31802	3221 N ANDRITA ST	90065	13	154-5A213  99	5458016023	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Issued	09/07/2016 12:00:00 AM	ADDRESS	34.11823	-118.24369	ROOF MOUNTED PVPV1 SFD TOTAL SYSTEM SIZE 3KW AC USING CENTRAL INVERTER SYSTEM AND 8 MODULES. PV SYSTEM IS CONNECTED TO METER ADDRESSED 3221 ANDRITA.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36711	17041-20001-12202	16188 W ROYAL OAK ROAD	91436	5	162B141   272	2286013015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM			PC Approved	04/23/2017 12:00:00 AM	ADDRESS	34.13958	-118.48337	VOIDED APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36712	16041-10000-45246	10250 W SANTA MONICA BLVD # 2840	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Cotton on Kids"" Ste. 2840.  Install new wiring, and  panels, total area 1910 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36713	17041-10000-44282	1001 S GAYLEY AVE #104	90024	5	132B149    43	4363025012	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.06169	-118.44797	Plan check for T24 only, permit is covered under the express permit# 17041-30000-40636. TI on existing commercial space,  panels are existing to reuse, new connected load <200A.(B# 17016-10000-17034)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36714	15041-10001-23651	2215 E ALCAZAR ST	90033	14	135A227   139	5202001008	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.06357	-118.20153	03/01/16Changes to an approved set of plans. All changes are made under delta 2. Scope includes voltage drop calculations for the speaker circuits, and revisions to the battery calculations. (((((INSTALLATION OF FIRE ALARM DEVICES = 1008 NEW FIRE ALARM SYSTEM(5) CONTROL PANEL(1) FIRE ALARM PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36715	11041-10001-02184	10861 W LINDBROOK DR	90024	5	132B153   205	4360002032	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM			PC Approved	04/19/2011 12:00:00 AM	ADDRESS	34.06023	-118.44294	T.I. for existing restaraunt.  1900 sgft Restaraunt  <<<<<<CHANGE TO LIGHTING, T-24 ONLY OTC PLAN CHECK.  CONTRACTOR TO USE EXISTING PERMIT>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36716	14041-20000-06296	115 N CAROLWOOD DR	90077	5	141B157   100	4358005025	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.08122	-118.42568	PLAN CHECK FOR NEW 600A SERVICE FOR CONSTRUCTION TRAILERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36717	11041-10000-07139	530 S HEWITT ST #121	90013	14	126A215   370	5163028***	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.0407	-118.23473	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36718	11041-10000-02122	310 E WASHINGTON BLVD	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			02/03/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	33.98034	-118.46425	New fire sprinkler system, for three story cond.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36719	18041-10000-34440	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	06/08/2020 12:00:00 AM		Permit Finaled	05/14/2021 12:00:00 AM	ADDRESS	34.03145	-118.41085	Full plan check for change of use. Scope includes a new 800-Amp distrubution board, new equipment, and lighting with total Title-24 area cover 19,000-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36720	12041-20000-04753	6767 W FOREST LAWN DR #200	90068	4	162B181   617	5581028005	C1-1D	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM			PC Approved	03/01/2012 12:00:00 AM	ADDRESS	34.14432	-118.33993	T.I. to a second floor.  Install general/emergency lighting.  Plan check for energy only.Permit issued under 12041-20000-04755	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36721	17041-10002-23337	11401 N PORTER RANCH DR BLDG 8	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 8 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 41 unit apartment with 1600 amp 208 volt service.       Building 8 of 10.  Type IV.       Building permit #17010-10000-02385	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36722	15041-20000-41345	600 WORLD WAY TERM. 6-655	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (TERMINAL RESTUARANT/CAFE ON TERMINAL 6 UNIT 655 FB). SCOPE INCLUDES NEW LIGHTING AND PANELS. TOTAL AREA IS 2547 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36723	10041-10000-00747	13488 W MAXELLA AVE	90292	11	105B153    78	4212004012	[T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Public Safety Only			01/25/2010 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	33.98592	-118.44252	Plan check for installation methane detection system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36724	18041-10000-08153	11100 W SANTA MONICA BLVD STE 250	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.04726	-118.44465	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES AN OFFICE TI. TOTAL SQ. FT. 2332	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36725	09041-10001-24177	801 N FAIRFAX AVE #104	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM			PC Approved	05/21/2010 12:00:00 AM	ADDRESS	34.08567	-118.36172	REVISIONS TO PERMITTED SET OF PLANS- CHANGE LUMINAIRE IN THE BATHROOM AND REMOVE CURRENT LIMITER FROM TRACK LIGHTING SYSTEMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36726	16041-20001-18267	14505 W FORTUNA LANE	91402	6	198B149   635	2644030215	(T)(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM			PC Approved	06/20/2016 12:00:00 AM	ADDRESS	34.24234	-118.44837	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 5.1 kW. This is an addition of  PV modules plus microinverter to an existing system. Additional of 8 modules and 8 microinverters.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36727	17041-10001-20279	211 W AVENUE 33	90031	1	142-5A221 271	5205005013	UC(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.08355	-118.21499	DESIGN BUILT: Energy plan check for a studio T.I ; Scope includes new lighting,  receptacles, and equipment.  Portion of the permit fee is paid under original application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36728	17041-10000-23751	11605 W HART ST	91605	2	183B169   191	2320001023	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.19767	-118.38493	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 41400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36729	13041-20000-03797	7926 N CHASTAIN AVE	91335	3	189B129   682	2101029005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	34.21437	-118.52351	Photovoltaic system on roof of single family dwelling using enphase inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36730	16041-10000-37879	14235 W VENTURA BLVD	91423	4	165B153   335	2265019007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.15022	-118.44335	PC FOR TITLE 24 ENRGY ONLY. TI for a restaurant.SCOPE INCLUDES NEW LIGHTS AND NEW RECEPTACLES. TOTAL AFFECTED AREA OF 3340 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36731	15041-20000-37886	341 N CENTRE ST	90731	15	018B201   379	7449012009	R2-1XL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	33.74581	-118.28363	PV system. Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system. Using 300W power optimizers (1 per module). (16) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36732	17041-20000-33029	9444 W SIERRA MAR PL	90069	4	147B165   602	4392004017	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.09556	-118.39524	NEW 3 STORY SINGLE FAMILY DWELLING - NEW 800A 208Y/120V SERVICE.  PLAN CHECK FOR POWERPERMIT FEES UNDER COMBO PERMIT.BLDG PERMIT UNDER 16010-20000-04838	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36733	14041-20000-29363	11668 W SHERMAN WAY G 206	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.20103	-118.38683	TI TO AN EXISTING THREE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND CIRCUITS.  956 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36734	18041-10000-44383	1325 E PALMETTO ST	90013	14	126A217    34	5164003018	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.04045	-118.23165	PC FOR A NEW FIRE ALARM SYSTEM IN A (E) COMMERCIAL BLDG. 87 FA DEVICES AND 5 FA PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36735	14041-10001-04673	14476 W VALLEY VISTA BLVD	91403	4	165A151   158	2276038018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/01/2014 12:00:00 AM	PIN	34.14652301	-118.44956559	EXPEDITED RSES PLAN CHECK PER APPLCANT REQUEST.{{PV1, INSTALL 7.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(31) MODULES:  CNADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36736	19041-10000-33684	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	PLAN CHECK TO RELACE FOUR OUTDATED EXITING FIRE ALARM PANEL WITH NEW PANELS IN AN OFFICE BUILDING (HIGHRISE). FLOORS 1ST, 3RD, 11TH AND 20TH. ALL DEVICES AND WIRING ARE EXISTING TO REMAIN. ADDITION OF 2 MONITORS TO PANEL FACP-1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36737	16041-10000-45273	10250 W SANTA MONICA BLVD 1375	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Rolex"" Ste. 1375.  Install new wiring, and  panels, total area 1409 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36738	17041-20000-25311	10132 N WISNER AVE	91345	7	204B145   651	2660020026	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.25459	-118.46185	Plan check for a PV1 roof-mounted PV system. System size is 7.5 kWac and consists of (30) modules, (30) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36739	14041-20000-23755	9999 W BARLING ST	91040	7	204B181   282	2543021002	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.25232	-118.34965	PV1INSTALL GROUND MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(52) ET SOLAR MODULES P660250(2) POWER ONE PVI-6000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36740	18041-10000-46362	12806 W LA MAIDA ST	91607	4	168B161   379	2357017017	R1-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.15841	-118.41194	$0.00 fees due to senate bill 12222 and lb1414PC FOR ROOFMOUNTED PV SOLAR SYSTEM WITH 42 MODULES(JINKO JKM290M-60B) AND 42 OPTIMIZERS (P320 SOLAR EDGE). 1 INVERTER 10KW. NEW 225A PANEL. PV SYSTEM SIZE IS 12.180KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36741	18041-20000-37236	17161 W SHERMAN WAY	91406	6	183B133  1011	2227018029	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.20137	-118.50734	Plan check for a PV1 roof-mounted PV system. System size is 7.59 kWdc/6.83 kWac-CEC and consists of (22) AC PV modules and (1) load center. MSP is center-fed.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36742	19041-10000-44168	12201 W VICTORY BLVD	91606	2	180B165   675	2322006024	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM			Reviewed by Supervisor	11/06/2019 12:00:00 AM	ADDRESS	34.18686	-118.39901	"PLAN CHECK FOR POWER & ENERGY. INSTALLING NEW PANELS, LOADS, LIGHTS, CIRCUITS, ETC IN A NEW ""BLINK"" GYM . (((BUILDING PERMIT: 19016-10000-34735, FIRST TIME TENANT))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36743	19041-10000-17393	6223 W FRANKLIN AVE	90028	4	150A189   170	5586006028	C1-1D	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Issued	05/15/2019 12:00:00 AM	ADDRESS	34.10539	-118.32503	Energy plan check for a TENANT IMPROVEMENT CONVERT ONE RETAIL SPACE INTO THREE RETAIL SPACES. Scope includes new lighting and equipment with total lighting area is 2569-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36744	16041-10000-30402	1331 S MENLO AVE	90006	1	129B197  1232	5056001041	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Expired	10/12/2018 12:00:00 AM	ADDRESS	34.04633	-118.29067	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(31)MODULES-CANADIAN SOLAR CS6P (31)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE7600A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36745	12041-10000-13364	14723 W RINALDI ST	91340	7	213B149   125	2612015011	C2-1, P-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM			PC Approved	09/17/2012 12:00:00 AM	ADDRESS	34.28045	-118.45413	Plan check for energy only. Existing Popeyes. Indoor lighting and outdoor lighting. 2948 combined sqft (indoor + outdoor). Occupancy load is 99 or less.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36746	17041-20002-19895	11115 W MCCORMICK ST	91601	2	171B173   389	2350018915	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	34.16605	-118.373	01-04-2018 Changes to an approved set of plan, Changes include relocate electrical room from 1st floor to basement. All Changes has been clouded. No new equipment added, relocated equipment only, permt fees covered under master. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36747	12041-20000-01463	14920 W PARTHENIA ST	91402	6	195B149   610	2653010018	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	Apartment			01/20/2012 12:00:00 AM			Verifications in Progress	11/21/2013 12:00:00 AM	ADDRESS	34.228	-118.45803	117 units apartment building complete renovation check for final fee. PLAN CHECK HAS EXPIRED, APPLICANT TO FILE VARIANCE TO EXTEND PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36748	19041-10000-07918	1023 N COLE AVE	90038	13	144B185   869	5533014023	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.08956	-118.33005	REMOVING HID FIXTURE AND REPLACE WITH NEW LED FIXTURES TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36749	14041-20002-05012	20522 W HAMLIN ST	91306	3	180B109   566	2148014010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.18901	-118.5806	Changes from previously approved plans.  Changes include relocate modules on roof and remove AC disconnect.  Note: Permit is under the original application.  $00.00 Plan check fee due to Senate Bill from 2012.Previous Description:PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.2KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36750	17041-20001-46480	10936 N SHARP AVE	91345	7	210B149  1139	2615028020	RA-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.26862	-118.44755	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.7.6kW ungrounded pv system. (29) 325W pv modules. (29) 400W power optimizers.(2) 5kW Tesla Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36751	15041-10000-03662	4810 W SUNSET BLVD	90027	13	147B197   737	5543017018	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.09792	-118.29436	T24 only. Installation of exterior lighting.  Total area = 25,134 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36752	18041-10000-14740	813 S FLOWER ST	90017	14	129A207   189	5144021031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	06/14/2021 12:00:00 AM	ADDRESS	34.04705	-118.26051	NEW FIRE ALARM SYSTEM ON (E) 12 STORY HOTEL.HIGHRISESCOPE OF WORK INCLUDES NEW (1) FA PANEL, (746) DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36753	15041-20000-11319	412 N CLIFFWOOD AVE	90049	11	135B137   578	4405011003	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM			PC Approved	07/07/2015 12:00:00 AM	ADDRESS	34.06344	-118.48706	Plan check for power only.  New single family dwelling with 600 A service. PERMIT FEES COLLECTED UNDER BUILDING PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36754	12041-10002-19990	546 N OXFORD AVE 1-25	90004	13	141B193  1005	5521013004	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			08/20/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	34.08121	-118.30785	CHANGES TO AN APPROVE SET, NOTE CHANGES ON DELTA 1. SCOPE INCLUDES CHANGE OF FIXTURES WITH IN UNIT SPACE. PC PER APPLICANT'S REQUEST. (((CHANGES TO AN APPORVED SET, NOTE CHANGES ON DELTA C. SCOPE OF WORK INCLUDES CHANGE TO LED LIGHTING IN COMMON AREA AND OUTDOOR. )))(((PLAN CHECK POWER ANS ENERGY FOR NEW 25-UNIT APARTMENT BLDG; 2-STORY BLDG. WITH BASEMENT PARKING GARAGE. 1200A SERVICE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36755	15041-10000-02875	8927 W ST IVES DR	90069	4	144B169   662	5560018003	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.09381	-118.38753	Plan check for power. Scope of work is the upgrade of a 400-amp rated main service panel to a 600-amp rated main service panel. Permit fees have already been paid except for 2 steam generators and service upgrade. Full plan check done on supplemental application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36756	17041-20002-09876	12601 W PIERCE ST BLDG 4	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/27/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY.Note: Permit fees are paid under Master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36757	18041-20000-02157	17647 W KITTRIDGE ST	91406	6	180B129   432	2229017014	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.19036	-118.51801	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (12) modules, (1) load center, and (1) Tesla PowerWall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36758	19041-10000-34422	5805 E ARROYO DR	90042	1	150A229   145	5492007002	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.10568	-118.18924	PLAN CHECK ONLY. CHANGES TO APPROVED PV SET. CHANGE THE LOCATION OF EQUIPMENT TO THE NORTH EAST SIDE. (((PV1 NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3KWac/2520KWdc. SCOPE OF WORK INCLUDES 8 MODULES (HANWHA Q CELLS 315), A CENTRAL INVERTER (NINGBO GINLONG).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36759	19041-10000-14059	12813 W BESSEMER ST	91606	2	177B161   754	2332030005	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.18041	-118.41208	Plan check for a PV1 7.6KW AC roofmounted system with (27) modules and (1) inverter interconnecting though the service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36760	17041-10000-15203	4256 N ENSENADA DR	91364	3	165A107   260	2190012032	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.14614	-118.59713	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5.75 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36761	18041-30000-06634	1411 S OCEAN FRONT WALK	90291	11	106-5A143   7	4226007002	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	33.98778	-118.47426	Plan check for Title 24 only in existing space bathroom. Total area: 525 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36762	17041-20000-20901	5611 N FIGUEROA ST SUITE 5	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.10937	-118.19392	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR STUDIO.  1312 SQFT. SUITE 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36763	12041-20000-28768	19641 W BERMUDA ST	91311	12	207B117   184	2708011018	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.26524	-118.56211	Enphase system on roof of single family dwelling with subpanel installation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36764	14041-10000-00057	5807 S AVALON BLVD	90011	9	108B205  1107	5101006005	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.98959	-118.26538	PLAN CHECK FOR POWER AND ENERGY. TI FOR  9525 SQ FT 1 STORY DIALYSIS CLINIC.  No invasive procedures.BUILDING PC # 14016-10000-00031	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36765	18041-10000-11886	8525 N GLENOAKS BLVD	91352	6	192B177   132	2404025176	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.22544	-118.36249	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36766	15041-20000-34026	1200 W WASHINGTON BLVD	90007	1	126A201   195	5135014041	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Expired	01/11/2018 12:00:00 AM	ADDRESS	34.03937	-118.28357	PC FOR FIRE ALARM SYSTEM. NEW FIRE SPRINKLERS AND ASSOCIATED DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36767	18041-10000-48963	9420 N TOPANGA CANYON BLVD	91311	12	198B105   244	2746013040	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.24152	-118.60597	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36768	17041-20000-45152	444 S FLOWER ST SUITE 600	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for energy only. TI to 6th floor office in high rise building. New lighting (incl. emergency) - 19,341sqft. Building plan check application #17016-10000-36057.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36769	11041-10000-16574	5210 W LOS CABALLEROS WAY	90027	4	151-5A195  68	5588035006	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2011 12:00:00 AM	08/08/2011 12:00:00 AM		Permit Finaled	10/19/2011 12:00:00 AM	ADDRESS	34.11044	-118.30351	NEW ROOF MOUNTED PV SYSTEM FOR A SINGLE FAMILY RESIDENCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36770	18041-20000-43130	22727 W DEL VALLE ST	91364	3	171B097   435	2040031030	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Apartment			11/09/2018 12:00:00 AM	11/02/2021 12:00:00 AM		Issued	11/02/2021 12:00:00 AM	ADDRESS	34.16582	-118.62109	Plan check for power and energy. Project site is a new 3-story, 16-unit apartment building. Work includes a new 800 amp service and a total lighting area of 20,111 sq. ft.Note: Building application has been generated under 18010-20000-02868	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36771	15041-20000-07222	16633 W VENTURA BLVD #735	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for T-24 only. T.I. in existing office space. Total area: 1447 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36772	11041-20000-17581	19945 W SEPTO ST	91311	12	201B113    38	2726003028	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2011 12:00:00 AM	09/12/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.25105	-118.56845	New 13.7 KW roof mounted Photovoltaic system for a SFD. Permit includes upgrading main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36773	18041-20000-08396	18825 W SATICOY ST	91335	3	186B121    91	2103016040	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Issued	03/07/2018 12:00:00 AM	ADDRESS	34.20853	-118.54321	Plan check for the addition of devices onto an existing fire alarm system for a commercial building. Fire alarm system is changing to a voice-evac system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36774	10041-10000-14863	900 S WESTGATE AVE	90049	11	129B145   397	4265017041	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01, 2643.02	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	ADDRESS	34.05068	-118.46804	NEW FIRE ALARM SYSTEM. PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36775	17041-10000-07409	20221 S HAMILTON AVE	90502	15	054B197    33	7351033022	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	33.84695	-118.28626	T-24, PC FOR ENERGY ONLYT. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLESFOR AN EXISTING OFFICE SPACE ON THE 2ND AND 3RD FLOOR. TOTAL AFFECTED AREA IS 26315 SQ. FT. B#16014-10000-05525	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36776	17041-10000-07847	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	Yes	1897.01	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Issued	10/19/2017 12:00:00 AM	ADDRESS	34.13829	-118.34154	Plan check for Title 24 only outdoor lighting golf cart Charger total area: 1080 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36777	18041-20001-45343	7401 N LANKERSHIM BLVD	91605	2	186B169   690	2317017002	(T)(Q)RAS4-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.20485	-118.38824	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA B ONLY. CHANGES TO SWITCHGEAR AND FEEDER SIZE.<<<Plan check for power and energy. Project site is a new 5-story, 108-unit mixed use building. Building is 4 levels of residential over 1 level of commercial/parking over 1 level of basement parking garage. Work includes a 3,000 amp service and a total lighting area of 98,580 sq. ft.Note: Building application has been generated under 17010-20000-02985>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36778	13041-20001-05712	616 E VENEZIA AVE PV1	90291	11	108B145  1432	4237004005	R3-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	33.99034	-118.45901	((((ADDED 22 MODULES AND 1 COMBINER BOX ON THE SUPPLEMENTAL PERMIT. NEW TOTAL SYSTEM SIZE: 8.085KW))))INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 2.695 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36779	16041-10000-30862	221 N WESTMORELAND AVE	90004	13	138B197   515	5501008024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.07516	-118.28805	PC for energy only for an existing commercial building (Central City Value High School). Adding new lighting and receptacles for 2 office spaces within the campus. Total sqft = 251.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36780	16041-10000-11799	5916 1/2 N FIGUEROA ST	90042	1	151-5A229 114	5492015028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.1106	-118.19037	PC FOR POWER AND ENERGY. T.I FOR A RESTURANT. ADDING TWO NEW PANELS: 600A NAD 225 A. TOTAL AREA 1717 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36781	19041-20001-09452	17617 W TROSA ST	91344	12	219B129    59	2608029002	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM			PC Approved	04/04/2019 12:00:00 AM	ADDRESS	34.30048	-118.51763	Revisions to approved set.  Deletion of new load center - interconnection made at MSP.  $0 plan check fee due to State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((PLAN CHECK FOR PV ROOF MOUNTED SYsTEM FOR EXISTING SFD, SYSTEM SIZE: 8.64KW DC, 7.68 KW AC. SCOPE OF WORK INCLUDES (24) SUNPOWER AC MODULES WITH FACTORY INTEGRATED 320W MICROINVERTERS, AND (2) 100A SOLAR LOAD CENTER PANELS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36782	13041-10000-03153	557 S SPRING ST	90013	14	129A211   274	5149035014	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.0463	-118.25087	"Applicant said ""not a hi-rise"". NOTE TO INSPECTOR: verify in field if hi-rise and if generator is being used to serve emergency loads.PC for energy with emergency lights. TI for new cafe on first floor of existing 8 story building."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36783	11041-10001-12353	620 W 2ND ST	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.0545	-118.25027	REVISED APPROVED SETOF PLANS- NEW LOADS WERE ADDED TO THE SERVICE FOR THE PARKING STRUCTURE. THIS INCLUDES A FIRE PUMP, PANELBOARDS AND UPGRADING DISTRIBUTION BOARDS WHEN NECESSARY. CHANGES TO THE LIGHTING SYSTEM IS MINIMAL.((((((((((NEW PARKING STRUCTURE / MUSEUM BUILDING ( 3-LEVELS PARKING AND 3-LEVELS FOR MUSEUM) THIS APPLICATION  IS FOR THE SERVICE AND DISTRIBUTION FOR THE PARKING STRUCTURE; APPLICATION FOR THE MUSEIUM WILL FOLLOW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36784	13041-10000-35048	1100 S SAN PEDRO ST H06	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.03515	-118.25194	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 384 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36785	15041-20001-11271	10800 W ROSE AVE	90034	5	120B161   624	4254022035	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.02542	-118.41571	Expedited per customer request.PV2. Apartment Building. Install roof mounted PV system sized 14 kW. Interconnected with main service panel. (66) Canadian Solar 255P Modules(2) SMA America SB 7000 Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36786	19041-20000-48663	1563 S FAIRFAX AVE	90019	10	129B173  1078	5068021010	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			11/25/2019 12:00:00 AM	03/31/2021 12:00:00 AM		Permit Finaled	01/28/2022 12:00:00 AM	ADDRESS	34.04785	-118.36762	Install 600A 240/120V 1ph-3w service, distribution, power, and lighting for new building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36787	17041-10000-02612	1420 W 240TH ST	90710	15	042B193   774	7439012005	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	33.80717	-118.30221	PC for title 24. Outdoor. Remove HID fixtures and replace with new LED fixtures. Area: 16,900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36788	18041-20001-15016	14001 W OSBORNE ST	91331	6	195B153   210	2642031021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.23346	-118.43824	Revisions to approved set of plans.  Updated fault current values for labeling of equipment and note revisions on SLD sheet. (((PC FOR  POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO I 2.1 AMBULATORY OCCUPANCY.SCOPE INCLUDES NEW SERVICES AT 800A 120/208 3PH WITH NEW AND EXISTING PANELS, NEW CIRCUITS AND EQUIPMENT.  TOTAL AFFECTED AREA 38129 SQ. FT. B# 17016-10000-29190)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36789	14041-10001-17379	12154 W MONTAGUE ST	91331	7	204B165    89	2537018027	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM			PC Approved	04/16/2015 12:00:00 AM	ADDRESS	34.25712	-118.39806	CHANGE FEEDERS FROM COPPER TO ALCHANGES ARE CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36790	17041-20000-18438	22801 W ROSCOE BLVD Bldg. 2	91304	12	192B097   578	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.22014	-118.62547	Change of use from educational institution to medical reserach office (non-clinical).  Plan check for power and energy.  BUILDING PERMIT ISSUED UNDER 16016-10000-27352	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36791	13041-10002-14295	10110 N AMESTOY AVE PV 1	91325	12	204B133   424	2694012022	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.25442	-118.5066	PV1.  Supplemental application to express permit 13041-20000-14295.  Install 10.045 kW DC.  Addition of 15 extra modules, change to 2 PVI-3.6 inverters (transformerless).   Original permit description: INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 6.37 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36792	14041-10000-10879	608-612 S MATEO ST	90021	14	126A217   187	5164013013	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.0376	-118.23251	plan check for power and energy. T24 done as performance - applicant to bring in prescriptive method. 1 story.  Methane Buffer zone. Installation of 600A equipment.CHANGE OF USE & INT REMODEL: CONVERT EX OFFICE/WAREHOUSE/PRINT SHOP INTO 2 TENANT  SPACES: 1) 612 MATEO ST -  OFFICE & 2) 608 S. MATEO ST - MASSAGE PARLOR . see bldg#14016-10-00088.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36793	16041-20000-14572	1111 S FIGUEROA ST 2nd FLoor	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.04338	-118.26581	"TI in 490 sq. ft. concession space - ""Cooler by Budweiser"" at Staples Center.  Plan check for energy."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36794	14041-20000-13289	2635 N PARADISE DR	90032	1	139-5A227 108	5209022019	[Q]RE20-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.0771	-118.19845	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 864 WATTS. USING ENPHASE M215. USING MICROINVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36795	11041-20000-25526	4836 N LANKERSHIM BLVD	91601	2	168B173   298	2353019015	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Expired	12/25/2013 12:00:00 AM	ADDRESS	34.15888	-118.3708	PLAN CHECK T24 ENERGY FOR BEAUTY SALON. PERMIT FOR NEW LIGHT FIXTURES ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36796	14041-20000-00536	1320 N SYCAMORE AVE	90028	4	144B181    59	5548023102	RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			01/08/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.09495	-118.34269	Change to lighting in the lobby of an existing low-rise apartment building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36797	15041-10000-33687	4501 W COLORADO BLVD	90039	13	162B205    19	5593012033	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM			PC Info Complete	01/06/2016 12:00:00 AM	ADDRESS	34.14246	-118.2705	PC for power only. Intallation of a new auxiliary (non-required and supplementary to (E) fire pump on site per applicant) fire pump rated at 150 hp in an existnig high rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36798	18041-10000-05548	420 S WESTLAKE AVE	90057	1	133-5A205 204	5154026016	R4-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.06005	-118.2727	**Zero Permit Fee per CA Senate Bill 1222**ROOF MOUNTED PV ON COMMERCIAL ROOF. SYSTEM SIZE 87KWAC/85.44 KWDCSCOPE INCLUDES 244 MODULES WITH 4 CENTRAL INVERTERS, TRANSFORMER AND NEW PANEL. B#18016-10000-04718	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36799	13041-10001-12486	7203 N RUBIO AVE	91406	6	183B137    51	2226016015	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			01/17/2014 12:00:00 AM			PC Info Complete	01/17/2014 12:00:00 AM	ADDRESS	34.20163	-118.49594	CHANGES MADE TO THE PREVIOUSLY APPROVED SET , TITLE 24 FOR OFFICE AND BATHROOM AREA., ALSO PANEL FOR THIS AREA WAS REMOVED FROM HOUSE PANEL AND WAS ADDED TO THE RESIDENTIAL SECTION. AND ONE METER WAS   ADDED TO THE METER BANKS.   1-17-14  MZANDI   )))))))))((((((((PC FOR POWER/ENERGY. NEW 29 UNIT APT.4STORY.1ST FLOOR grade level  AND 3 STORies above. 8 typical units. not methane . fully sprinklered. engr = robert tomasiaCONSTRUCT NEW 29 UNIT APT AND SALE OFFICE AS AN ACCESSORY USE TO THE BUILDINGNO PROGRESS - PC APPROVE IS FOR GRADING PERMIT R&R ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36800	13041-20000-14919	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	t24 for existing commercial area. indoor 5865 sqrft. outdoor 34000 sqrft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36801	15041-10000-27836	1028 E VERNON AVE	90011	9	112-5A209  63	5108028007	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.00368	-118.25756	NEW OUTPATIENT OFFICE BUILDING WITH (2) STORIES OF OFFICE (B-OCC.) OVER (1) STORY PARKING AT GRADE LEVEL (S-2 OCC.) FULL PC FOR MEDICAL BUILDING NON-OSHPD3.3/15/16: Obtained Conduit only permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36802	16041-10002-29090	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Info Complete	09/07/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR CHANGES TO APPROVED SET OF PLANS. T24 PLAN CHECK. CHANGES NOTED DELTA ASI-S001. UPDATED LIGHTING BASED ON CHANGES SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36803	15041-10000-03619	8631 W 3RD ST MOT 301E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Expired	03/02/2017 12:00:00 AM	ADDRESS	34.07373	-118.38036	Energy plan check for a nonmedical office located inside a medical building. branch circuits pulled under permit #15041-90000-03374	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36804	17041-10000-09552	8486 W 3RD ST	90048	5	138B173   778	5511032028	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.07318	-118.37592	TI FOR EXISTING RESTAURANT REMODEL. CONNECTED LOAD <400.PLAN CHECK FOR ENERGY ONLY (TOTAL 1479 SQ FT.) INDOOR AND OUTDOOR LIGHTING. NEW SERVICE RATED AT 400 AMPS, ALL NEW EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36805	12041-20000-09356	4710 N NOMAD DR	91364	3	168B113   355	2175039013	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	34.15597	-118.56807	solar single family 15.6 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36806	13041-20000-26038	2917 E 1ST ST	90033	14	126A225    32	5180020031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			09/19/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.04084	-118.20294	NEW FIRE ALARM SYSTEM FOR APARTMENT BUILDING. 1 FIRE ALARM PANEL, 1 ANNUNCIATOR, AND 306 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36807	17041-20002-40108	17512 W CORINTHIAN DR	91316	5	168B129   461	2290012028	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.15687	-118.51466	Revisions to approved set of plans.  Module roof layout, main service panel location, and racking system modified.$0 plan check fee due to State Senate Bill SB 1222. (((pv1install roof mounted pv system sized 11.4kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36808	14041-10000-19613	3708 N EAGLE ROCK BLVD	90065	1	154-5A217 154	5457029020	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM			PC Approved	07/23/2014 12:00:00 AM	ADDRESS	34.11757	-118.23347	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HABITAT CAFE. FOOD PREPARATION. 1560 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36809	17041-10002-18964			13	150A185   307	5547004044	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			08/08/2018 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	PIN	34.10416578	-118.33435654	REVISED SINGLE LINE DIAGRAM TO SHOW SERVICE RATED FUSED DISCONNECT AND TRANSFORMER ADDED TO SUPPLY THE FIRE PUMP (((((((((((Plan check for power and energy.  Service upgrade and electrical renovation for existing 5 story 64 unit apartment building with 9 hotel units.  New 2,000 amp 208 volt service and 30 HP fire pump.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36810	19041-20000-49210	555 S MATEO ST BLDG 1	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	02/02/2021 12:00:00 AM		Permit Finaled	12/28/2021 12:00:00 AM	ADDRESS	34.03943	-118.23302	Distribution, power, and lighting for kitchen and dining area in commercial office building.  Plan check for power and energy.  2 separate electrical permits under same plan check approval:19041-20000-4921219041-20000-49213	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36811	16041-10000-38991	10250 W SANTA MONICA BLVD 1870	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER AND ENERGY. THE INTERIOR BUILDING OUT OF AN EXISTING SHELLED OUT TENANT SPACE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36812	14041-20000-04102	13439 W BURBANK BLVD	91401	2	174B157   540	2343015018	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			02/13/2014 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.17234	-118.42584	New 2 story apartment, 22 units, with grade parking.  New 1000A service, switchboard, subpanels, and lighting.  Plan check for power and energy.Note: Elect. plan check is under 2008 NEC.  A variance submitted to separate fire alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36813	19041-20000-13254	11464 N AMIGO AVE	91326	12	213B121   438	2871011003	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.27996	-118.54106	Plan check for PV roof mounted system, system size: 5.89KW AC, 6.49KW DC with 22 PV Modules and 1 inverter(6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36814	18041-10003-12963	5156 S BRYNHURST AVE	90043	8	108B185   121	5013007015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	33.99513	-118.33314	DELTA 4 CHANGES TO AN APPROVED SET OF PLANS. REMOVING THE EXISTING J-BOX FROM THE SINGLE LINE DIAGRAM TO REFLECT THE CHANGES TO THE INSTALLED SYSTEM. PC ONLY____________________________________________________________________________((ORIGINAL SCOPE)): PV1. ADDING A NEW STRING OF MODULES FOR AN EXISTING PV SYSTEM. SCOPE INCLUDES ADDING 7 MODULES. ADDING 1.96KWdc TO AN EXISTING 3.06KWdc PV SYSTEM. TOTAL DC WATTAGE FROM EXISTING AND NEW IS 5.02KWdc.  THE AC SYSTEM SIZE REMAINS 3.6KWac. (7)MODULES-Q-CELLS # Q. PLUS-G4.1/SC-280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36815	12041-10000-07697	1030 N ALVARADO ST #100	90026	13	139-5A207 119	5404003036		East Los Angeles				1957.20	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	06/07/2012 12:00:00 AM		Permit Finaled	08/14/2012 12:00:00 AM	ADDRESS	34.07715	-118.26352	First time tenant for a 3,784 sq ft commercial space.  828.3A of load and occupant load is 75.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36816	19041-20000-14400	9143 W CRESTA DR	90035	5	129B169  1274	4305026013	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.04646	-118.38971	Plan check for battery back up system install into existing PV System, install 3 Tesla Power Wall 2.0 (13.5kWh)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36817	15041-20000-00976	1965 N CHEREMOYA AVE	90068	4	150A189    42	5586013015	RD1.5-1XL	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2015 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	PIN	34.10709185	-118.32079397	PV1. Install roof mounted PV system sized 3.2 kW. Interconnected with main service pannel. (15) modules(15) microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36818	17041-10000-07059	616 N HOOVER ST	90004	13	141A201    55	5401001017	C1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1959.03	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM			PC Approved	03/06/2017 12:00:00 AM	ADDRESS	34.08209	-118.28432	PC for energy only. Interior TI to an existing wine shop. connected load < 400 A. total area 910 sq ft ( including outdoor and indoor lightig).B # 16016-10000-28700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36819	14041-20001-26395	8101 N BOBBYBOYAR AVE	91304	12	189B093    72	2020019017	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.2174	-118.63349	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.0KW INTERCONNECTED TO MSP.(56) KYOCERA KD255 MODULES(2) SOLAREDGE 6000 INVERTERS(56) POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36820	19041-10000-52533	400 S MAIN ST	90013	14	129A213   162	5148008001	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	08/03/2020 12:00:00 AM		Issued	08/03/2020 12:00:00 AM	ADDRESS	34.04787	-118.24721	FULL PLAN CHECK FOR A NEW 600A, 120/240V SERVICE. SCOPE OF WORK INCLUDES 8 PANELS CONNECTED TO THE NEW SERVICE AND 1 PANEL CONNECTED TO AN EXISTING 1600A SERVICE. TOTAL AFFECTED AREA IS 16071.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36821	11041-10000-19324	5348 N BOTHWELL ROAD	91356	3	171B117    51	2164018013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2011 12:00:00 AM	09/12/2011 12:00:00 AM		Permit Finaled	02/22/2012 12:00:00 AM	ADDRESS	34.16861	-118.56101	Install a 6000 watt photovoltaic inverter on roof top of a single family dwelling along with photovoltaic modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36822	12041-10001-14719	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM			PC Approved	10/29/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	REVISION TO APPROVED PLANS. CHANGES TO LIGHTING. PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR T.I. FOR OFFICES ON 14TH & 15TH FLOORS (#1400, 1500, & 1550) OF HIGH-RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36823	15041-20000-09369	18634 W VENTURA BLVD	91356	3	174B121   624	2161015002	C2-1VL	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.17006	-118.53986	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EUROPEAN WAX CENTER. 1417 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36824	18041-10002-12192	900 W OLYMPIC BLVD #F51	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	05/11/2018 12:00:00 AM	ADDRESS	34.04526	-118.26611	Install (2) New Battery back up system 18.6 kWh, this system is tied with New 7.6kW AC (under master plan check#)<<<NEW SOLAR ROOF SYSTEM ON A HIGH RISE RITZ HOTEL/RESIDENTIAL. THIS PV IS ONLY FOR (1) UNIT PENTHOUSE (#F51). INSTALL (10) MODULES, (1) CENTRAL INVERTER SE7600A-US, (1) 10Kva TRANSFORMER TO STEP UP THE VOLTAGE FROM 120/240V TO 208V. SYSTEM INTERCONNECT AT 600A SUBPANEL. SYSTEM SIZE AT 7.6 KW AC ~~ 18041-10000-12192>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36825	18041-10001-24837	4141 W SANTA MONICA BLVD	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM			PC Approved	06/17/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	T-24 Energy Only. Restaurant TI  Install Subpanels and Circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36826	10041-20000-20786	11541 N BLUCHER ST bldg1	91344	12	213B145    79	2605002012	QC1-1VL, QP-1VL	North Valley	Granada Hills - Knollwood		YES	1092.00	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	PIN	34.27943684	-118.47043731	Permit expired (BLDG. 1).  EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36827	19041-20000-27008	832 N COLE AVE	90038	13	141B185   109	5533028002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.0862	-118.32971	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from warehouse to motion picture production. Total lighting area = 1,550 sq. ft.Note: Building application has been created under 19016-10000-02811	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36828	17041-30000-26126	400 S DETROIT ST	90036	4	135B181   386	5508006027	[Q]R4-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Apartment			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.06668	-118.34497	Plan check for replace existing panel to new addressble fire alarm control panel with existing fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36829	17041-10000-16222	1423 W 12TH PL	90015	1	127-5A203  53	5137030916	C2-1, CR-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.04454	-118.27417	PC for energy only. Outdoor Title-24. Removing exsiting HID fixtures and adding new LED lights. Area: 12,000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36830	12041-10000-28671	16208 S VERMONT AVE	90247	15	069B197   287	6120017804	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	33.88408	-118.29119	INSTALL FUEL CELLS (1)ES-5400, (2) ES5700 & HARDWARE. 1200A MAIN.   SInce this job was not approved originally there fore it wold not allow to issue permit on 10001.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36831	10041-10000-18263	6150 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/15/2010 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	12/21/2011 12:00:00 AM	ADDRESS	33.94474	-118.39224	"TI IN AN EXISTING OFFICE AREA AND HANGER AT LAX FOR ""RATHEON"" (ADJACENT TO DELTA HANGER).  PLAN CHECK IS FOR POWER AND ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36832	14041-20000-34634	10700 W SANTA MONICA BLVD #315	90025	5	129B157   367	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.05167	-118.432	TI TO SUITE 500. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36833	17041-10000-08779	407 N HARBOR BLVD	90731	15	018B201   343	7449007025	[T][Q]C2-2D-CDO	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	33.7463	-118.27986	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 53 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36834	13041-10000-26214	621 S AVENUE 61	90042	14	150A231   369	5312024066	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.10594	-118.18157	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200A MAIN IN A 2-STORY HOUSE. TRANSFORMERLESS ON A NON-STANDARD PLAN. SYSTEM SIZE IS 4.655 WITH (19) MODULES: TRINA #TSM-245PC05/PA05.18(1)POWER-ONE #AURORA PVI-4.2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36835	14041-20001-12029	12642 W SANDHILL LANE Unit #2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.97765	-118.41437	Fee for expedite only.*****Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 2 of 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36836	16041-10004-08982	9938 N DEBRA AVE	91343	12	201B137    30	2678015015	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.25138	-118.49043	09/19/2016 Changes of an approved set of plans. Changes include relocate service equipment, disconnecting means inverters, solar load center performance meter. Changes has been clouded. ((((((PV1 rooftop solar installation 12kW system    (39) SPR327NE-WHT-D     (1) SB7000TL-US   (1) SB5000TL-US   (1) 125A load center)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36837	10041-10002-25237	600 W 7TH ST	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM			PC Approved	05/16/2011 12:00:00 AM	ADDRESS	34.04728	-118.25685	REVISED SINGLELINE ON SHEET E-110 TO SHOW INPUT CIRCUIT BREAKER SIZE INCREASED TO 800AF/700AT TO PREVENT NUISANCE TRIPPING BY THE BATTERY UNITS;  RELOCATED THE UPS OUTPUT DISTRIBUTION BOARDS TO ELCTRICAL ROOM ON THE 4TH FL((((((((((((((((BUILT-OUT FOR NEW DATA CENTER ( SUITE 570 ) AND ELECTRICAL ROOM ( # 440 )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36838	17041-20002-13844	18035 W BURTON ST	91335	12	192B125   710	2101020017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.22001	-118.52641	Revisions to approved set of plans.  (1) fewer module, rearrangement of module layout on rooftop, relocation of equipment.  Additional rapid shut down devices to accommodate new array locations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36839	16041-10001-36686	7560-7562 W MELROSE AVE	90046	5	141B177   652	5526016002	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.08353	-118.35473	02/16/17Changes to an approved set of plans. Changes include revising single line diagram for an existing Retail tenant space. Utilizing existing services to feed existing building loads, and revising power floor plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36840	15041-10000-09581	11211 S LA CIENEGA BLVD	90045	11	087B173    85	4129038024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	33.93287	-118.37022	PV2, TI-24 PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36841	13041-10000-35786	1800 N ARGYLE AVE	90028	13	150A189   301	5546033015	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Closed	07/07/2017 12:00:00 AM	ADDRESS	34.10384	-118.32506	Temporary power for Argyle Hotel Tower.  New 800A service.REGULAR PC # 13041-10000- 30569PLAN CHECK FOR POWER AND ENERGY. 16 STORY HIGH RISE HOTEL WITH 200 ROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36842	14041-10000-30155	200 WORLD WAY Level 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	Remodel of airport LAX terminal 2 exit corridor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36843	17041-20000-22783	14620 W RUNNYMEDE ST	91405	6	186B149   461	2218005006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.2057	-118.45194	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36844	17041-10000-36411	700 W 7TH ST 6220	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			Corrections Issued	01/17/2018 12:00:00 AM	ADDRESS	34.04797	-118.25815	Full PC for power and energy. Change of use from Retail to Retail/Restaurant and TI  on ground level. Scope includes new lights, receptacles, and panelboards. Total affected area is 9097 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36845	18041-10000-10865	3418 N DREW ST	90065	13	156B213   299	5458026015	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.12114	-118.24112	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36846	18041-20000-49188	13369 W WENTWORTH ST pv1	91331	6	195B157  1072	2627006028	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.22773	-118.42431	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36847	14041-20000-22228	12245 W VIA SANTA BARBARA	91342	7	228B165    83	2581006***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.31912	-118.40032	PV1Central Transformerless Inverter standard planInstall roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW(1) PowerOne PVI6000 transformerless inverter(28) REC Solar REC260PE pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36848	15041-10000-42490	633 W 5TH ST 39TH FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN OFFICES ON THE 39TH FLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36849	17041-10000-30890	742 S WESTLAKE AVE 1-37	90057	1	132A203   246	5142003007	R4-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Apartment			08/29/2017 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.05473	-118.27626	New apartment building. 37 units. PC FOR POWER AND ENERGY. Total area:32,128 sq ft.  B# 16041-20000-03561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36850	16041-10000-35601	23559 W MARIANO ST	91367	3	174B093   554	2044009012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.16884	-118.64058	PV1 roof mounted solar system installation to a singel family home. Installing 2 central inverters rated at 7.0 kw each for a total system size of 14 KW. 50 new solar modules. Permit fees are $0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36851	10041-10000-21742	600 W WORLD WAY term 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Closed	06/29/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Installation of  temporary HVAC system consisiting of 18 ea 5-tons and 5 ea 25-tons cooling units) through the terminal areas under construction.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36852	17041-10000-42365	7150 W MELROSE AVE	90046	5	141B181   640	5525015001	C2-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.08327	-118.34527	PC FOR POWER AND ENERGY FOR A NEW RESTAURANT IN EXISITING BUILDING. TOTAL CONNECTED LOAD >400ASCOPE INCLUDES NEW PANELS CIRCUITS EQUIPMENTS AND LIGHTS. TOTAL AFFECTED AREA 3590 SQ.FT. B# 17016-10000-34819	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36853	10041-20000-22588	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	NEW FIRE ALARM SYSTEM PEREIRA HALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36854	16041-10001-20332	682 W 9TH ST	90731	15	015B197   799	7454005021	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	33.73624	-118.29185	Supplemental PC for power only for new 600A service for new restuarant. Installing 600A 120/208V service, two panels, receptacles, lights and equipment. T24 portion was approved under master permit 16041-10000-20332 and is included in set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36855	15041-20000-04716	11309 W TIARA ST	91601	2	177B173  1251	2337010016	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.17864	-118.37716	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.  (27) KYOCERA MODULES(1) ABB PV-6000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36856	14041-20000-19042	16900 W NORDHOFF ST	91343	12	195B133     9	2688025012	(Q)C2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.23558	-118.50041	Plan check for energy only. Existing bank building (single story), remodel of bathrooms and break room. New lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36857	18041-10000-42810	755 N LA CIENEGA BLVD	90069	5	141B173   242	4337002075	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.08514	-118.37686	Plan check for a fire alam system located in restaurant with (1) fire alarm panel, (1) power supply, and (62) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36858	13041-10000-33885	807 E 12TH ST STE 149	90021	14	123A211    42	5132009013	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.03247	-118.25043	Plan check for T24 only. Remove HID light fixtures and replace with new fluorescent fixtures in a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36859	09041-20001-11252	4228 W PICO BLVD	90019	10	129B185  1102	5082023024	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	02/26/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.04757	-118.32795	supplimental permit to existing permit number 09041-20000-11252 additional circuit and others.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36860	13041-10001-13638	4729 N EAGLE ROCK BLVD	90041	14	159A221    95	5685027016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.13117	-118.21666	[[[[[ DELTA 4 CHANGES TO APPROVED SET OF PLANS ON NEW PCIS # 13041-10000-26453 ]]]]]TI TO EXISTING BLDG. RETAIL TO RESTAURANT. max city bbq	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36861	15041-20000-00376	2179 N LINDA FLORA DR	90077	5	153B145   220	4377009007	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2015 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.11198	-118.46506	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service pannel.(18) Sunpower SPR-X21-345 modules(1) Sunny Boy 6000TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36862	13041-10002-36010	8500 W BEVERLY BLVD 2ND FLOOR	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	INTERIOR REMODEL OF 2ND FLOOR IN THE BEVERLY CENTER. PROJECTED ARE IN LIGHTING SCOPE OF WORK IS APPROX. 44,000 SQ FT. TAILOR METHOD FOR COMPLIANCE APPROACH. SIGN LIGHTING WILL ALSO BE INCLUDED ON THE COMPLIANCE FORMS.BUILDING PERMIT UNDER: 13016-10000-26364	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36863	16041-20000-42754	5406 N CALVIN AVE	91356	3	174B117   648	2163003052	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Expired	04/13/2024 12:00:00 AM	ADDRESS	34.16904	-118.55617	pv1install roof mounted pv system sized 7.6kw interconnected wtih msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36864	11041-10000-20861	1515 W 259TH ST	90710	15	033B193   124	7411007056	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	PIN	33.78853649	-118.30323305	ALTERATIONS IN AN INDUSTRIAL BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36865	18041-20000-29331	241 N COPA DE ORO ROAD	90077	5	141B153   249	4362013013	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.07998	-118.43999	Plan check for new energy storage system for 2 PowerWall 27KWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36866	14041-20001-13348	7635 N POMELO DR	91304	12	186B093    82	2027001004	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.2091	-118.63882	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.96KW INTERCONNECTED WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS SE SE5000A(43) TRINA SOLAR MODULES TSM-PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36867	16041-20000-30683	6909 N CORBIN AVE	91306	3	183B117   779	2135018013	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Issued	01/19/2017 12:00:00 AM	ADDRESS	34.19589	-118.56241	Plan check for battery backup charger/utility interactive inverter system for SFD. Roof-mounted solar array of (8) 315W pv modules. Schneider Conext SW 2524 NA.  (8) 6V batteries. (1) charge controller. 200A MSP.$2.16 permit fee per State Senate Bill SB 1222 permit fee cap.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36868	19041-20000-26609	20946 W LANARK ST	91304	3	189B109   161	2109008026	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.21739	-118.59017	PLAN CHECK FOR ADDITION OF A 9.8KWH ENERGY STORAGE SYSTEM TO EXISTING SFD WITH A EXISTING PV SYSTEM. SCOPE OF WORK INCLUDES A LG CHEM RESU10H BATTERY, AND A 100 BACK UP LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36869	18041-10000-38071	11100 W SANTA MONICA BLVD 8TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR OFFICE TI - PARTITION AND FINISHES, FALL FLOOR. NON-BEARING INTERIOR PARTITION WALLS. - TOTAL AFFECTED AREA = 12304 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36870	13041-20000-22367	24440 W INDIAN HILL LANE	91307	12	186B089   477	2031013061	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.20511	-118.65548	PV1 CENTRAL INVERTER. 33 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36871	17041-10000-31985	920 W DOWNEY WAY BASEMENT	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.02063	-118.28879	PC for T24 only for educational lab TI. PC for new lights. Installing three new panels, lights, circuits, receptacles and equipment. B 17016-10000-25997. Total affected area 1969sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36872	15041-10002-27136	22520 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	33.82142	-118.30137	CHANGE TO APPROVED SET OF PLANS. ADD PERFORMANCE METER AND FUSED DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36873	16041-20000-33649	1540 S FIGUEROA ST	90015	14	126A205   196	5134009011	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.03782	-118.26962	Remove existing hid fixtures and replace with new led fixtures.  plan check for energy outdoors only.  total square footage 45000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36874	19041-10000-49117	1355 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   194	5037001024	C2-1L-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.01106	-118.29969	PC FOR POWER ONLY. SCOPE INCLUDES A NEW 400A  120/240 SINGLE PHASE SERVICE, ONE NEW 200A PANELBOARD, AND NEW CIRCUITS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36875	12041-10000-13341	10241 N BALBOA BLVD	91325	12	204B133   240	2694001900	A2-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	09/18/2012 12:00:00 AM	ADDRESS	34.25698	-118.5026	New Fire alam system with one new panel and 42 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36876	13041-10000-06801	453 S SPRING ST	90013	14	129A211    87	5149024001	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			Reviewed by Supervisor	06/20/2013 12:00:00 AM	ADDRESS	34.04778	-118.24948	photovoltaic system for commercial building. HIGH RISE. PV2. TOTAL SYSTEM SIZE ABOUT 60 KW. USING TOTAL OF 279 PANELS. SINGLE INVERTER. NON STANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36877	17041-20003-45197	6150 N LAUREL CANYON BLVD Bldg H	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	07/09/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	Revisions to approved set.  Miscellaneous revisions to SLD to accommodate power and signage additions.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36878	09041-10007-24367	3327 E SABINA ST Bldg B	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			12/20/2011 12:00:00 AM			PC Approved	12/20/2011 12:00:00 AM	ADDRESS	34.0306	-118.20046	Changes to permitted set of plans. Attached sheets outlines the changes-Delta 6 to the plans. New Apartment Complex w/ multiple buildings (Bldg B)  2 of 2.  4 typical units, 48 units total.  Permit is for service, distribution, new ckts, busway, panels.  P/C is for Power and energy. Modification to seperate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36879	11041-10001-18125	4101 S CRENSHAW BLVD	90008	8	114B185   323	5032002066	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.00994	-118.33552	T.I.  ExistingWalmart.  Remodel of the pharmacy, visual, and freezer area.  Additional emergency lighting added.  Additional loads and new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36880	16041-10000-36675	14523 W SHERMAN WAY UNIT B	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.20136	-118.44972	Plan check for T-24 only. TI on (E) commercial space with new tenant RESTAURANT (JERSEY MIKE'S).  Install new lights, receptacle and 1 panel with new load < 400A. Other electrical equipments are existing. Total affected area: 1,098 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36881	19041-10000-46140	6121 W SUNSET BLVD	90028	13	147A189   234	5546026044	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	12/07/2020 12:00:00 AM	ADDRESS	34.09818	-118.32309	TI OF EXISTING OFFICE SPACE & WORK LOUNGE ON THE 2ND FLOOR OF A LOW RISE BULDING. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.  AFFECTED AREA: 1681 SFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36882	18041-10000-45299	11635 W SHELDON ST	91352	6	201B169   103	2537023015	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Reviewed by Supervisor	12/12/2018 12:00:00 AM	ADDRESS	34.24543	-118.38567	NEW ROOFTOP MOUNTED 10 KVA PV SYSTEM ON (E) COMMERCIAL BUILDING(28) MODULES, (1) 10 KVA  AC SYMO 10.0-3 INVERTER1 OF 2 PV SYSTEMS ON SAME BUILDING, OTHER ON PERMIT #18041-10000-45294	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36883	14041-20000-19744	19344 W LUDLOW ST	91326	12	210B117   158	2718024017	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.27092	-118.55478	PV1.  Install 4.08 kW roof-mounted, utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36884	13041-20000-09976	5811 N CAPISTRANO AVE PV-1	91367	3	174B101    55	2040042002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.17648	-118.61693	Pv-1. 11.4kW DC. two 5kW inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36885	16041-10000-32787	1800 N HIGHLAND AVE	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.10436	-118.33763	t-24, PC FOR ENERGY ONLY. INTERIOR OFFICE TI ON THE 6TH FLOOR OF AN EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10234 SQ. FT. B#16016-10000-17672	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36886	18041-20000-29505	14820 W CHATSWORTH DR	91345	7	207B149     7	2615022***	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.26861	-118.45551	PV1.  Install 5.94 kW roof mounted grid tied PV system.  (18) modules with 6kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36887	19041-20000-39440	15255 W PALISADES VILLAGE LANE B1M-115	90272	11	129B125   863	4423016078	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.04758	-118.52462	Tenant improvement of existing storage P.C for title-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36888	17041-20000-45915	5401 N LANKERSHIM BLVD	91601	2	171B173    55	2350012031	C2-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	07/26/2023 12:00:00 AM	ADDRESS	34.16918	-118.37756	Plan check for power and energy. Project site is a new 7-story, mixed-use building: 5 levels of residential (totaling 127 units) over 2 levels of commercial with two levels of subterranean parking garage. Total lighting area = 150,098 sq. ft.Note: Building application has been generated under 17010-20000/20001-03994	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36889	17041-10000-40162	537 S KENMORE AVE	90020	10	135B197   921	5502020012	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.06435	-118.29682	Remove HID fixtures and replace with new LED fixtures  T-24 only.3605 SQ.FT OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36890	11041-10000-16079	1519 N GAFFEY ST	90731										Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM			PC Approved	08/01/2011 12:00:00 AM				TI TO AN EXISTING 7-ELEVEN STORE.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36891	18041-10000-21031	3800 S VERMONT AVE	90037	9	117B197   615	5037028912	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Issued	09/26/2018 12:00:00 AM	ADDRESS	34.01684	-118.29134	4160V  SERVICE AND ASSOCIATED SERVICE EQUIPMENT, DISTRIBUTION BOARDS, MV UNIT SUBSTATIONS,PANEL BOARDS IN THE FIRST PHASE FOR THE CONSTRUCTION OF THE PROPOSED LUCAS  MUSEUM.  THIS PLAN REVIEW IS FOR EQUIPMENT OUTLINED ON THE SINGLE LINE DISGRAMS-LIFE SAFETY, OPTONAL, AND LEGALLY REQUIRELOADS. MOST OF THIS EQUIPMENT WILL BE LOCATED IN THE GARAGE LEVELS P2 AND P1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36892	18041-10000-22988	1601 N HOBART BLVD 1-54	90027	13	148-5A195 289	5544020010	[Q]R4-2	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.09995	-118.30593	Install new FA system on a 54 units (53 units affordable multifamily units) construction; 4 Story Apartment, over Subterranean Basement Garage.  (136) devices, (1) FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36893	19041-10000-25548	3100 W SUNSET BLVD	90026	13	142-5A203 287	5426016008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	10/12/2019 12:00:00 AM	ADDRESS	34.08441	-118.27456	T-24 PLAN CHECK FOR A CHANGE USE OF EXIST SERVICE STATION TO ICE CREAM RESTUARANT. SCOPE INCLUDES NEW 400A SERVICE, EQUIPMENT, LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1139 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36894	19041-10000-43342	12833 W VENTURA BLVD 118	91604	2	165B161   920	2375021022	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			Reviewed by Supervisor	11/05/2019 12:00:00 AM	ADDRESS	34.14508	-118.41248	Full plan check for a 1st time T.I. Scope includes new lighting and equipment with a total lighting area of 3,985 SQ FT.(((per buildiing application, TENANT IMPROVEMENT OF 3985 SF  RESTAURANT. NEW PARTITIONS, FINISHES, FIXTURES, KITCHEN EQUIPMENT, NEW ROOFTOP UNITS)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36895	16041-10004-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM			PC Approved	08/05/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET.  ALL CHANGES ARE CLOUDED UNDER DELTA 11. CHANGES INCLUDES REVISING SINGLE LINE DIAGRAM, SHORT CIRCUIT CURRENT, AND AIC RATINGS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36896	13041-10000-18900	610 W 98TH ST	90044	8	093A201   355	6054023012	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Expired	08/18/2015 12:00:00 AM	ADDRESS	33.94711	-118.28505	PV1 SOLAR INSTALLATION ON A NON STANDARD PLAN. SYSTEM SIZE IS 4.9KW DC. USING TRANSFORMERLESS INVERTER AND POWER OPTIMIZERS. 20 MODULES 2 STRINGS [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 ||||| INVERTER: SOLAREDGE # SE50000A-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36897	18041-10000-41259	3858 S HARVARD BLVD	90062	8	117B193  1178	5036011007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Issued	10/29/2018 12:00:00 AM	ADDRESS	34.0156	-118.3066	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 3.60KWdc / 3.36KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER AND A METER ADAPTER. (12)MODULES-SOLARWORLD  SW-300(12)OPTIMIZERS-ENPHASE S280--60-LL-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36898	18041-20000-04912	610 S VAN NESS AVE	90005	4	135B189   927	5504018011	RD3-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	03/01/2021 12:00:00 AM	ADDRESS	34.06273	-118.3152	Two 4-story 6-unit apartment buildings with common 600A 208Y/120V 3ph-4w service. Building 1 of 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36899	15041-20000-04545	788 S GRAND AVE	90014	14	129A209   223	5144012058	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	PIN	34.04589729	-118.25735415	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW PANELS, TRANSFORMERS, CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.  FEES ESTIMATED PLAN CHECKER TO VERIFY. New whole foods supermarket. fire time tenant. part of high rise	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36900	14041-10000-21036	1234 W 7TH ST	90017	1	130-5A207 158	5143009003	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM			Not Ready to Issue	08/05/2014 12:00:00 AM	ADDRESS	34.05185	-118.26696	Fire Alarm System, permit is existing under differenrt  pcis number .  this is plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36901	13041-10003-31237	1038-1048 S MARIPOSA AVE	90006	1	129B197   387	5078016016	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			03/29/2016 12:00:00 AM			PC Approved	03/29/2016 12:00:00 AM	ADDRESS	34.05151	-118.2988	"03/29/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE MADE UNDER DELTA 4. CHANGES INCLUDE REMOVING PANEL ""INV"" FROM THE SINGLE LINE DIAGRAM, AND RELOCATING 'INV' LOADS TO PANEL 'HP'. NOTE: PERMIT PAID UNDER PCIS#13041-10000-31237(((((DELTA 3 REVISIONS IN THE FIELD: INVERTER WAS REMOVED AND UNIT EQUPMENT USED FOR EGRESS ILLUMINATIONCHANGES ARE CLOUDED AND IDENTIFIED"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36902	10041-10000-24573	4153 W BEVERLY BLVD	90004	13	138B197   319	5520025006	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM			PC Approved	12/17/2010 12:00:00 AM	ADDRESS	34.07643	-118.29966	Ti in an existing retail. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36903	13041-10000-23151	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	FIRST TIME TENANT AT LAX TBIT. EMIRATES LOUNGE. 4 PANELS 1 75 KVA TRANSFORMER. PLAN CHECK FOR POWER AND TITLE 24 PART 6 ENERGY.***********************************************BUILDING APPLICATION NUMBER 13016-10000-17427.TI (EMERIT AIRLINE) LOUNGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36904	16041-20000-32843	2543 S AMHERST AVE	90064	11	120B149   396	4257023046	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.02552	-118.4485	BATTERY STORAGE SYSTEM + PV1 ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36905	14041-10000-20889	3150 W SAN FERNANDO ROAD	90065	13	153B209   408	5458002013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.11582	-118.24713	Title 24 plan check only.  Total area = 2,463 sq. ft.T.I. to existing commercial space.  New plugs, panel, and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36906	16041-20000-31691	15954 W VOSE ST	91406	6	183B141   342	2224007042	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Expired	10/26/2021 12:00:00 AM	ADDRESS	34.19824	-118.48106	PV1INSTALL ROOF MOUNTED  PV SYSTEM (ACM) INTERCONNECTED WITH MSP.  SYSTEM SIZE 14.7KW.Note: $0.00 permit fee due ot Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36907	17041-10001-04621	20039 W RINALDI ST BLDG A6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.27566	-118.57078	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DETLA 3. CHANGES INCLUDE REVISING EXTERIOR LIGHTING LAYOUT, REVISING ROOF-LAOUT, REVISING TITLE 24 CALCULATIONS, AND REVISING SINGLE LINE DIAGRAM.PLAN CHECK ONL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36908	18041-20000-48778	24328 S STERLING RANCH ROAD	91304	12	192B089   204	2017039015	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.21883	-118.65587	Plan check for a PV1 roof-mounted PV system. System size is 2.835 kWdc/3 kWac and consists of (1) inverter and (9) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36909	15041-10000-14218	6330 W SAN VICENTE BLVD # 230	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.06116	-118.36804	TENANT IMPROVEMENT INSIDE EXISTING OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36910	15041-20000-07691	5723 N AURA AVE	91356	3	174B117   158	2153033021	[Q]RZ5-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.175	-118.55443	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system with 25 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36911	17041-10000-11251	5212 W WILSHIRE BLVD	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	34.06205	-118.34351	FULL PC FOR FIRST TIME TENANT. THIS IS BEVMO. PC OR POWER AND ENERGY. NEW DISTRIBUTION AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36912	17041-10000-15428	101 E TERMINAL WAY	90731	15	018B205147	7440030904		Harbor				9800.31	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	33.73961	-118.27172	POWER PLAN CHECK FOR  A PUMP STATION UPGRADES. UPGRADING SERVICE AND UPGRADES OF MOTOR PUMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36913	15041-20000-14390	5426 S CRENSHAW BLVD	90043	8	108B185   458	5006008008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	33.99232	-118.33045	PC FOR PV SYSTEM. 3KW AC USING SINGLE TRANSFORMERLESS INVERTER. THIS SYSTEM CONNECTS TO TENANT AT 5426 CRENSHAW. THIS IS PROJECT 4/5. ALL SYSTEMS CONNECT TO SINGLE 400A SINGLE PHASE SERVICE. ZONING AND CRA HAVE BEEN CLEARED UNDER PROJECT 1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36914	19041-10001-33517	17819 W LOS ALIMOS ST	91344	12	207B129   197	2712021012	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			Reviewed by Supervisor	09/04/2019 12:00:00 AM	ADDRESS	34.2663	-118.52222	FEE EXPEDITEPV1 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND DC BATTERY COUPLED SYSTEM. (20) MODULES, (20) OPTIMIZERS, (1) 7.6 INVERTER, (1) 5KW lg CHEM BATTERY. TOTAL SYSTEM SIZE IS 7.6 KWAC / 6.583KWDC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36915	15041-10001-17779	222 S HOPE ST	90012	14	132A211    90	5151004***	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM			PC Approved	11/10/2015 12:00:00 AM	ADDRESS	34.05463	-118.25117	CHANGES TO APPROVED SET OF PLANS. REMOVING OUTDOOR WORK PART OF SCOPE OF PERMIT. NO OTHER CHANGES. REMOVE OUTDOOR LIGHTING, POWER AND TITLE 24 FROM SCOPE OF THIS PERMIT. ALL CHANGES CLOUDED RED. LOADS ON PANEL AND SERVICE TO BE CONSIDERED FOR FUTURE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36916	18041-10002-34638	199 N ASHDALE AVE	90049	5	138B145   254	4366009013	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM			PC Approved	09/26/2018 12:00:00 AM	ADDRESS	34.07496	-118.46347	NEW ROOF MOUNTED 9.1KW PV SYSTEM WITH 28 PV MODULES PLUS 27KW ENERGY STORAGE SYSTEM ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36917	19041-20001-34473	10983 W BLUFFSIDE DR PV1	91604	2	162B173   285	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.1418	-118.36941	PV2 BUILDING #6 (N) 21.4 KW AC/23.76 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (66) PV MODULES WITH (1) 6 KW INVERTER, (2) 7.7 KW INVERTER, AND A 200A PANEL BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36918	18041-20001-44155	2444 N CHEREMOYA AVE	90068	4	154-5A189 484	5580005016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Apartment			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.11571	-118.32102	01/11/2019 Changes to an approved set of plans. Single line diagram has been updated to show PV interconnection configuration on the field.*****Original Work Description*****PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 6 MODULES (SW 325 XL MONO) AND 6  MICROINVERTERS.  SYSTEM SIZE IS 1.95KWdc and 1.68KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36919	19041-10001-31975	21255 W BURBANK BLVD SUITE 120	91367	3	174B105    87	2149019018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Issued	12/02/2019 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLAN CHECK FOR  CHANGES TO APPROVED SET, SCOPE OF WORK IS REVISIONS TO AN APPROVED FIRE ALARM SYSTEM, SCOPE OF WORK INCUDES ADDTIONAL DEVICES, CALCULATIONS HAVE BEEN UPDATED. NOTE ALL PERMIT FEES WILL BE UNDER 19041-10001-31975. NOTE THIS JOB WAS PREVISOULY SPLIT INTO THREE FLOORS. FIRST FLOOR IS UNDER 19041-10000-31975THE SECOND FLOOR IS UNDER  19041-10000-38943THE THIRD FLOOR IS UNDER 19041-10000-38944NOTE ALL CHANGES ARE CLOUDED UNDER DELTA 2. ---------ORGINAL WORK DESCRIPTION-----------PLAN CHECK FOR A TI TO AN EXISTING FIRE ALARM SYSTEM. SCOPE OF WORK IS ADDING DEVICES AND BATTERIES TO EXISITNG FIRE ALARM SYSTEM SPANNING THREE FLOORS. THIS IS THE FIRST FLOOR PORTION CONSISTING OF 25 DEVICES, AND ONE BATTERY. NOTE ALL FLOORS HAVE BEEN SEPARATED INTO THREE APPLICATIONS, ALL HAVE BEEN APPROVED BY FIRE. THE FIRST FLOOR IS UNDER 19041-10000-31975THE SECOND FLOOR IS UNDER  19041-10000-38943THE THIRD FLOOR IS UNDER 19041-10000-38944	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36920	19041-20000-09091	12125 W VAN NUYS BLVD	91342	7	216B165   216	2531033003	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1042.04	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Issued	03/13/2019 12:00:00 AM	ADDRESS	34.28467	-118.39693	PLAN CHECK FOR NEW 3.48 KW DC/ 3 KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (12) REC290TP2 BLK PV MODULES WITH P320 OPTIMIZERS, AND (1) SE3000H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36921	19041-20000-46683	2229 N STRADELLA ROAD	90077	5	153B145   169	4377011001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	12/07/2021 12:00:00 AM	ADDRESS	34.11352	-118.46263	Plan check for PV roof mounted system, PV system size: 16.28KW DC, 15.03KW AC CEC with 44 AC Modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36922	11041-10000-15593	5040 W WILSHIRE BLVD	90036	4	132B185    14	5507028029	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	ADDRESS	34.06191	-118.33903	TI TO AN EXISTING RESTAURANT.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36923	19041-30000-50036	23740 W LUND ST	91367	3	171B093   355	2047005003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.16567	-118.64379	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10KWac, SCOPE OF WORK IS 36 MODULES (HANWHA Q-CELL 315) WITH OPTIMZERS (SE P400), LEADING TO A CENTRAL INVERTER (SE10000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36924	10041-20000-01485	7500 N CHAMINADE AVE	91304	3	186B093    52	2027005009	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.20673	-118.63673	(N) performing arts building on (E) high school campus.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36925	13041-10000-11298	4411 W AVENUE 42	90065	14	159A217   138	5684004011	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Expired	05/27/2015 12:00:00 AM	ADDRESS	34.13076	-118.23032	PV1 - PLAN CHECK FOR 4.251KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING TRANSFORMERLESS INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36926	14041-10000-11768	11929 W COURTLEIGH DR 1-22	90066	11	111B157  1103	4233018022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	33.99687	-118.41943	NEW FIREALARM SYSTEM FOR LOWRISE APARTMENT BUILDING. 86 DEVICES and 1 facp and annunciator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36927	19041-10000-34642	2216 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.03778	-118.44068	PC for T24 only, scope of work is replacing lights in a wax rooms for LED. All controls and circuits are existing to remain. Total affected area is 400 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36928	14041-10000-13118	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.05069	-118.24861	T24 only , ice cream shop, existing service and panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36929	13041-20000-30341	10206 N MOUNTAIR AVE Unit 1-5	91042	7	204B197   948	2558021012	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			10/30/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.25442	-118.29306	11 units 2 stories apartments. These are two seperate buildings per applicant. This application covers the permits for Units 1-5 and House Panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36930	11041-10001-14359	240 E 6TH ST	90014	14	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			10/10/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	ADDRESS	34.0435	-118.24761	REVISED SINGLE LINE DIAGRAM TO SHOW THAT THE FIRE PUMP AND JOCKEY PUMP ALONG WITH THEIR ACCESSORIE WERE REMOVED. GENERATOR WAS REDUCED TO 400A(((((((((Add a 1-story parking garage over an existing 1 story commercial building.  Also adding an additional 4-story 102 unit apartment buildings (modular built -state-approved apartment units) on top.  Plan check is for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36931	14041-10001-25886	4121 N EAGLE ROCK BLVD	90065	14	156A219   137	5473006006	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Apartment			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.12142	-118.22666	PLANS ARE REVIVED TO SHOW THAT ELECTRIC RANGES RATING HAVE INCREASED. CALCULATIONS UPDATED TO REFLECT THESE CHANGES))))))Plan check for power and energy. Total area = 12500 sq. ft. New 4 story apartment building. Fire alarm variance.Building # - 14010-10000-02920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36932	16041-20000-19750	1030 W PACIFIC COAST HWY 2nd Floor	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.79073	-118.29408	TI to (E) open office space in 2-story commercial office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36933	14041-10001-31585	12746 W JEFFERSON BLVD #2103	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Change to approved set by changing light fixture type and the quantities of lighting.All changes are under delta-2 only.(((TI for yogurt shop.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36934	19041-10000-07916	614 E TERMINAL WAY	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	33.74201	-118.26431	INSTALL 2 NEW EQIPMENT PADS, CABLING, RACEWAY FOR WIRELESS CHARGING OF A FUEL CELL ELECTRIC TOP LOADER RATED AT 300KW EACH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36935	14041-10001-21238	2440 N HIDALGO AVE	90039	13	148-5A209 286	5440014023	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Apartment			08/06/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	34.10117	-118.25625	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36936	10041-20000-13426	10000 W REGENT ST 1-28	90034	10	120B165   830	4313006001	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2699.01	Electrical	Electrical	Apartment			07/14/2010 12:00:00 AM	08/26/2010 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.02498	-118.40155	Plan check for new 28-unit low rise residential apartment building. Modification to seperate fire alarms was filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36937	14041-20001-24756	10739 W STALLION RANCH ROAD	91040	7	204B177   260	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM			Verifications in Progress	02/03/2015 12:00:00 AM	ADDRESS	34.25715	-118.36484	Fee for Expedite ONLY.*****New Ground Mounted PV system with Enphase Microinverter, model M215-60-2LL.  Total system size 26KW (Plans shows 30KW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36938	16041-10001-34606	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM			PC Approved	09/15/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	PC FOR REVISION TO APPROVED SET UNDER BULLTIN ASI#10 SCOPE INCLUDES CHANGING CONFRENCE ROOM TO PRIVATE OFFICE  ON THE 8TH FLOOR ONLY.   REVISION TO LIGHTS AND T-24. PLAN CHECK ONLY!!!PERMIT UNDER ORIGINAL.TENANT IMPROVEMENT TO PARTIAL AREAS WITHIN 8TH AND 9TH FLOORS OF (E) MEDICAL HIGHRISE BUILDING.  DEMO OF OFFICE SPACES FOR EXPANSION OF LAB AREAS.  NEW PANELS WITH NEW LIGHTING AND RECEPTACLES + NEW ROOFTOP EQUIPMENT.  TOTAL AREA = 15,666 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36939	18041-20000-20696	6353 N VAN NUYS BLVD	91401	6	180B149  1035	2241004007	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.18585	-118.44901	PLAN CHECK FOR TITLE 24 ONLY FOR INTERIOR REMODEL TO RETAIL SPACE TO REPLACE (E). TOTAL AFFECTED AREA = 7051 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36940	08041-10001-22305	4501 S BROADWAY	90037	9	112-5A203 141	5110004034	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			Reviewed by Supervisor	05/13/2013 12:00:00 AM	ADDRESS	34.00277	-118.27861	supplemental application to originally approved plan.   Due to lack of fund no permit was pulled on the original application.  Same plan still exist, need to verify the Green Code requirement and if any new codes applies. Talk to Nabil for questions. Previous description of work :: Philantropic Institution. Includes space for offices, multipurpose rooms, gymnasium for youth activities, and activity rooms.  Still Apply	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36941	17041-30002-28178	1800 S AVENUE OF THE STARS STE675&685	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.06095	-118.41786	09-19-2017 Plan check for lost set of plan. plan check for Title 24 only. Permit shall refer to 17041-300000-28178************************************Previous work description*************************Plan check for Title 24 only in existing high-rise office High rise. Total area: 4435 sq ft. Building application number: 17016-10000-18930	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36942	17041-10002-16153	437 S HILL ST	90013	14	130-5A211 148	5149027013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Apartment			12/06/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.0495	-118.2514	FA plan check for Delta 2 only, change to 17041-10000-16153. This changes is to provide supplemental smoke purge system that ties to (E) FACP and tie-in elevator recall devices for elev.5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36943	19041-20001-06813	9315 S LINCOLN BLVD	90045	11	096B161   831	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	33.95584	-118.41565	Expedited plan check fee.PV2.  Install 60.48 kW DC / 54.28 kW AC roof mounted grid tied PV system.  (168) modules with (2) 30 kW rated string inverters. System 2 of 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36944	17041-20001-38463	12732 N PASEO DEL SERENO	91342	7	222B149  1170	2506031050	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.30187	-118.45229	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.Total system size: 3.22kW ungrounded.(14) EnPhase IQ6 microinverters.(14) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36945	19041-20000-00558	2307 W STRATFORD CIR	90049	5	150B141    24	4377044012	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	PIN	34.11133636	-118.47818733	Plan check for a PV1 roof-mounted PV system. System size is 14 kWdc/11.4 kWac and consists of (1) inverter and (46) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36946	13041-10000-25887	617 W 7TH ST BASEMENT	90017	9	129A209   113	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.04779	-118.2571	pc for power and energy. food prep and tasting room for botega louie. possible place of assembly. Electrical scope of work under this plan is installing panel HC1 , Xfr t-d and panel K5.  Load is under MSB only. FIRE ALARM PLANS ARE SUBMITTED SEPERATLY.glumac set of plans attached as reference for SLD.final fees to be verified: applicant brought check.PROPOSED INT T.I. OF EXISTING RESTAURANT AND FOOD PREPARATION USE IN THE BASEMENT FLR TO CREATE COOKING/KITCHEN AREA  AND TASTING/DINING AREA  AND MULTIPLE STORAGE AREA PER PLAN. (NO SERVING OF ALCHOLIC BEVERAGES).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36947	16041-20000-37509	17030 W GUNTHER ST	91344	12	213B133   175	2607014010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.2831	-118.50343	Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (30) AC modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36948	14041-20001-33661	16613 W NORDHOFF ST	91343	12	198B137   974	2687024007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM			PC Approved	12/31/2014 12:00:00 AM	ADDRESS	34.23587	-118.49438	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZE 10 KW INTERCONNECTED WITH MAIN SERVICE PANNEL.(30) SUNPOWER E327 MODULES(2) AURORA PVI-5000 TRANSFORMERLESS INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36949	15041-20001-32727	11984 N NUGENT DR	91344	12	216B129   189	2601051020	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.28902	-118.51577	Expedited per customer request.PV1. Install roof mounted PV system szied 11 kW. Interconnected with main service panel.(51) Kyocera KU 265 Modules(1) ABB PVI 6000 Inverter(1) ABB PVI 5000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36950	13041-10001-06807	747 N WESTERN AVE	90038	13	141B193   390	5535017001	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1916.10, 1917.10	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	PIN	34.0847511	-118.30949672	changes to approved set of plans: DWP gave them 3p4w 120/240V delta service instead of the approved 120/208V. layout on floor plan and the equipment didn't change per applicant (only rearranged so no High leg usage). PC for power only.CONSTRUCTION OF TENANT SPACE. CHANGE OF USE FROM PREVIOUS RETAIL SPACE TO NEW LAUNDRY MAT. DUE TO NEW LOADS AND CHANGE OF USE, BACK ROOM SUMBITTAL. NEW PANELS AND BRANCH CIRCUITS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36951	19041-20000-35445	890 N LINDA FLORA DR	90049	5	141B145   177	4369013002	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM			PC Approved	11/13/2019 12:00:00 AM	ADDRESS	34.08313	-118.46525	Plan check for 800 AMP 120/240 SINGLE PHASE SERVICE SIZE.Plan check only electrical permit covered under building conbination permit BLD# 18010-30000-03036	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36952	17041-20000-41211	333 S HOPE ST Suite 1150	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Issued	11/20/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for energy only. TI to office suite 1150 in high rise building. New lighting (incl. emergency) - 5,000sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36953	14041-20001-14174	20287 W VIA MEDICI	91326	12	219B113   151	2701043023	RE11-1-H, RS-1	North Valley	Chatsworth - Porter Ranch, Mission Hills - Panorama City - North Hills	North Hills West, Porter Ranch	YES	1082.02, 1173.03	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.2946	-118.57589	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array, interconnect with main panel. System size: 7.8kW(1) Power-One Aurora PVI-3.6-OUTD-S-US-Z-A transformerless inverter(1) Power-One Aurora PVI-4.2-OUTD-S-US-Z-A transformerless inverter(36) Trina Solar #TSM-255PA05.18 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36954	13041-20001-29812	12042 W WICKS ST	91352	6	195B165   207	2631019030	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.2328	-118.39514	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. TOTAL OF 18 MODULES.(((EXPEDITE FEES)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36955	17041-20001-42588	17130 W CLEMONS DR	91436	5	159B133   154	2292021010	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.1329	-118.5053	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36956	15041-20003-12842	11952-11954 W VENTURA BLVD	91604	2	162B169   153	2369016032	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.14327	-118.39243	02-10-2016 Change to approved set of plans. Changes include split bus panel to addition of sub panel. {{{{{{{{{{{02-05-16 Change to approved set of plans. Changes include location of equipments(compressor and vacuum), Emergency bug eyes and additional lighting fixtures. Changes apply to delta 3 only. ***************Changes to an approve set. all changes made under delta 2. Replacing indoor and outdoor lighting. (((Plan check for T.I.  Dental office(Medical Office). Total area: 2082 sq ft. New 400A service upgrade.)))*************}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36957	19041-10000-22828	2905 W EXPOSITION PL unit 3	90018	10	117B185    13	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.02038	-118.3277	Plan check for a 3KW AC/ 2.6KW DC PV2 roof mounted system with (1) inverter and (8) modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36958	13041-20000-19111	10550 N DENSMORE AVE PV-1	91344	12	207B141   594	2668011002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.26257	-118.47812	PV-1. Plan check for transformerless inverter. One 4.2kW inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36959	15041-10000-18359	10936 N ODESSA AVE	91344	12	210B137   763	2680009013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.2694	-118.49111	PV 1, ROOF MTD., SFD., 38 PANELS, 2 INVERTERS. TOTAL SYSTEM SIZE: 11KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36960	19041-10000-19099	13262 W GALEWOOD ST	91423	4	162B157   331	2385006034	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	34.14224	-118.42152	PC FOR PV-1, SYSTEM CONSISTS OF 1600SF TESLA SOLAR TILE, 4 INVERTERS (SOLIVIIA(1)3.8AND (3)7.6) , 1 200AMP LOAD CENTER.$0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36961	16041-20001-27289	14276 W CHASE ST	91402	6	192B153   343	2638024025	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.22467	-118.44452	09/29/2016 Changes to an approved set of plans. Changes have been reflected onto standard plan. Changes include the addition of (3) PV modules.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36962	19041-10000-48029	3025 E GLEASON AVE	90063	14	126A227    21	5179003031	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.03896	-118.20108	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36963	18041-10000-38022	166 S ALVARADO ST	90057	13	135A205   127	5154006010	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Apartment			10/04/2018 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	07/16/2021 12:00:00 AM	ADDRESS	34.06484	-118.27127	NEW METHANE MITIGATION SYSTEM - LEVEL V. <<<PROPOSED  84 UNIT,  5 STORY APARTMENT/GARAGE BUILDING. 1ST FLOOR IS TYPE IA AND THE UPPER 4 STORIES ARE TYPE IIB CONSTRUCTION. THE UPPER 4 STORIES ARE FACTORY BUILT HOUSING APPROVED BY THE STATE TO STACK 4 HIGH. (CARGO CONTAINERS ARE BEING USED)TOC, TIER 3 PROJECT: 83 ARE RESTRICTED AFFORDABLE (7 EXTREMELY LOW INCOME, 4 VERY LOW INCOME AND 72 LOW INCOME UNITS) STAIRS, PT SLABS ARE DEFERRED,>>>>BLDG PERMIT: 17010-20000-04073	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
36964	14041-20000-15576	20526 W SAN JOSE ST	91311	12	207B109   619	2707034005	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.26065	-118.58082	PV1.  Install 7.0 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36965	19041-20001-03011	15742 W SAN FERNANDO MISSION BLVD	91344	12	210B141   586	2662012018	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	PIN	34.27153203	-118.47547916	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CHANGE IN PV BREAKER LOCATION ON SINGLE LINE DIAGRAM, MAIN CIRCUIT BREAKER DERATED, FEEDER LENGTH CHANGED, VOLTAGE DROP CALC CHANGE, ELEVATION DRAWING CHANGE, AND CONDUCTOR SIZE CHANGED. CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36966	17041-10000-41563	1340 N GLENDALE BLVD	90026	13	141A209   393	5419032031	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			Corrections Issued	10/16/2018 12:00:00 AM	ADDRESS	34.07945	-118.25992	PC for power and energy for new one story retail building with subterranean parking. Installing 800A 120/208V service with two main distribution panels, panels, equipment, lighting and receptacles. Total area is 9251SQFT. B# 17010-10000-04509.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36967	17041-20000-22925	13762 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Closed	04/30/2018 12:00:00 AM	PIN	34.30869959	-118.43368746	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT, CHANGE OF USE FROM RETAIL TO RESTAURANT. 1549 SQFT.   Building p # 17016-20000-10197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36968	15041-10000-10582	1001 S TOWNE AVE # 103	90021	14	124-5A211 269	5132010049	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.03417	-118.24984	IN SALES AREA OF RETAIL STORE, REPLACE HID LUMINAIRES WITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36969	14041-10001-21160	11414 W CHALON ROAD	90049	5	144B145   240	4369027003	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	34.08807	-118.46354	TI at inspector's request.  Total area = 557 sq. ft.  Addition of 6 luminaires.Master permit work description: ELECTRIC CIRCUIT RECONFIGURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36970	12041-10000-07634	512 E ROSE AVE UNIT  F	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	FIRST -TENANT IMPROVEMENT - NEW RESTAURANT IN EXISTING RAW SPACE; NO CHANGE OF USE; NO STRUCTURAL WORK; NO EXTERIOR WORK; NO NEW FLOOR AREA; NEW OUTDOOR PATIO DINING AREA (BUILT-OUT NEW BUILDING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36971	18041-10000-24085	428 S ROBERTSON BLVD 1-37	90048	5	138B169   824	4334015037	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM	ADDRESS	34.07128	-118.38361	Methane Metigation system (Level III) in a New 6-story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36972	15041-10001-39687	5011 S NORMANDIE AVE	90062	8	111B193  1129	5016031024	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	PIN	33.99786079	-118.30049597	EXPEDITED PER APPLICANT.PV1, ROOF MOUNTED SOLAR SYSTEM. 21 MODULES AND 1 INVERTER. TOTAL SIZE: 7KW-AC.(21) SUNPOWER SPR-327-NE-WHT-D(1) SMA AMERICA SB700TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36973	13041-20000-35775	6151 W ORANGE ST	90048	5	135B177   434	5510026052	[Q]R3-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Apartment			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.06434	-118.36322	SPACE HEATER FOR CONDO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36974	19041-20000-22189	22135 W ROSCOE BLVD LOT #19	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 19.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36975	15041-20000-31584	1999 S AVENUE OF THE STARS 29 Flr	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	OFFICE TI TO 29TH FLR. PC FOR ENERGY ONLY. NEW LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36976	18041-10000-43975	718 S HILL ST 6TH FLOOR	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.04527	-118.25477	PC FOR A TI-FIRST TIME TENANT (POWER AND ENERGY) FOR A  LOW RISE OFFICE BUILDING. 6TH FLOOR. SCOPE INCLUDE NEW CIRCUITS, RECEPTICAL  AND LIGHTING. TOTAL AFFECTED AREA IS 5900 SQ.FTB# 18016-10002-03643	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36977	16041-10000-38170	9320 S LINCOLN BLVD	90045	11	096B161   862	4122022931	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			Corrections Issued	10/27/2016 12:00:00 AM	ADDRESS	33.95601	-118.41515	Paln check for Fire alarm system for Firest Flight Chld Development Center. Total fire alarm devices: 70 and 1 Fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36978	12041-10000-01378	1075 N WESTERN AVE #102	90038	13	144B193   779	5536019024	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	PIN	34.09038224	-118.30940652	PLAN CHECK POWER AND ENERGY FOR NEW DENTAL OFFICE  IN EXISTING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36979	19041-10000-45898	170 S GLESS ST	90033	14	127-5A219  27	5172003042	RD3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	03/10/2020 12:00:00 AM		Permit Finaled	09/29/2020 12:00:00 AM	ADDRESS	34.04542	-118.22293	0$ FINAL FEES PER AB1414PV2, NEW COMMERCIAL ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 40KWac/53KWdc. SCOPE OF WORK IS 136 MODULES (HANWHA 390), TWO CENTRAL INVERTERS (SMA STP 20000), LEADING TO TWO PV SUBPANELS, AND A BATTERY BANK THAT IS RATED AT 30KW. CONNECTED TO AN EXISITING 800A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36980	14041-10000-08727	16677 W ROSCOE BLVD	91343	6	192B137   321	2205003906	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1275.10	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.22044	-118.49652	REPLACE HID 400W LUMINAIRES WITH 6-LAMPS LUMINAIRES; WIRING AND CTRLS WILL REMAINPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36981	14041-20001-02011	7515 N LANKERSHIM BLVD	91605	2	186B169   441	2317009028	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Expired	06/15/2017 12:00:00 AM	ADDRESS	34.20703	-118.38798	4/30/2015 Changes to an approved set of plans. Changes include the installation of a new 400-amp switchgear, (1) 225-amp panel and associated loads, and lighting. Total lighting area = 2,886 sq. ft. The set of plans is under a new engineer.*****Previous Work Description*****TI FOR EXISTING RESTAURANT. OCCUPANT LOAD EXCEEDS 100 OCCUPANTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36982	19041-10001-03199	2012 S PELHAM AVE	90025	5	129B157   742	4321009056	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.04902	-118.42926	Change to an approved set by changing the model of module number from SC325 to SC330. All changes under delta-1 only.(((PV1. Install 4.874 kW roof mounted PV system. (15) modules with P400 OPTIMIZERS, (1) 5 KW rated string inverter. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36983	15041-10000-03577	4801 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.04683	-118.34063	Full plan check for a commercial building T.I (2-story with a basement furniture retail store).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36984	17041-10000-37289	8619 S HAAS AVE	90047	8	097-5A191 317	6036001044	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	33.95936	-118.31736	PC FOR ROOFMOUNTED PV ON SFD. SYSTEM SIZE 3.0KWAC/3.0KWDCSCOPE INCLUDES SINGLE INVERTER WITH 10 MODULESPOWERWALL 2 BATTERY INCLUDED WITH  (UNDER SUPP.)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36985	11041-20000-25683	4541 N COLFAX AVE	91607	2	168B169   967	2364007043	[Q]RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Apartment			12/02/2011 12:00:00 AM	03/19/2012 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	34.15324	-118.38793	New 12 unit townhome building with parking garage (more than 8 cars) on grade level.  New 600A service.  Plan check for power only.  Note - Title 24 for lighting in the garage will be submitted under a separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36986	14041-20001-16468	21013 W LULL ST PV 1	91304	3	186B105    60	2109020008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Expired	08/10/2016 12:00:00 AM	ADDRESS	34.20952	-118.59115	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM. 3.8KW SYSTEM INVERTER. using 14 modules. using standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36987	19041-10000-49495	1654 S LONG BEACH AVE	90021	14	120A213   343	5167002055	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.02167	-118.24257	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36988	19041-30000-06380	2000 S AVENUE OF THE STARS Suite 10	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for Title 24 only. Project site is an existing commercial tenant suite. Project scope is a tenant improvement. Total lighting area = 1,027 sq. ft.Note: Building application has been generated under 18016-30000-40490	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36989	15041-20000-10232	19119 W VICTORY BLVD BLDG 9	91335	3	180B121   530	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.18675	-118.54997	PV2. APARTMENT BUILDING. ( TWO MIRRORED BUILIDING ONE ADDRESS) (1 OF 2) BUILDING 9 , SYSTEM SIZE: 1.75 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
36990	18041-20000-16053	5842 W CARLTON WAY	90028	13	148-5A191 256	5545010004	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.10034	-118.31725	Plan check for a fire alarm system for a 5-story, 24-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, (3) RPSs, and (124) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36991	11041-10000-14943	10250 W CONSTELLATION BLVD	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	New fuel cell installation for office building.  Fuel cells are to be used as a back up electrical system for the building.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36992	19041-10000-09033	470 S SAN VICENTE BLVD	90048	5	135B173   177	5510005038	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.06943	-118.37497	T-24, energy only plan check for a Tenant Improvement. Change of Use from office to Credit Union. Scope includes new equipment, receptacles and lighting. Total affected area is 3239 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36993	16041-20000-31247	14645 W ROSCOE BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.22168	-118.45129	Plan check for energy only. Remodel existing restaurant (Wendy's). New indoor and outdoor lighting (incl. emergency). 1,890sqft indoor. 534sqft outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36994	17041-10001-30400			9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	PIN	34.0115196	-118.28314684	Changes made to previously approved set relocating ckts and panels.TI TO KITCHEN ON FIRST AND SECOND FLOOR AREAS. PC FOR POWER AND ENERGY. NEW DISTRIBUTION EQUIPMENT FOR KITCH LOADS AND LIGHTING. B#17016-10000-21655	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36995	19041-10000-41562	5757 W CENTURY BLVD #200B	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	33.9457	-118.38274	T-24 PLAN CHECK FOR A TI IN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 891 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36996	16041-10000-17736	6902 W HOLLYWOOD BLVD	90028	13	147B181   194	5548006008	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM			PC Info Complete	05/24/2016 12:00:00 AM	ADDRESS	34.10137	-118.34033	T-24, PC FOR ENERGY ONLY. INTERIOR FIRST FLOOR TENANT IMPROVEMENT TO 351 SQ.FT. OF 48,964 SQ.FT. RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 138 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
36997	19041-20000-38911	19216 W HAMLIN ST	91335	3	180B117   605	2128002***	QRD3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.02	Electrical	Electrical	Apartment			09/26/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.18835	-118.55235	PV2.  Install 5.28 kW DC / 4.488 KW AC roof mounted grid tied PV system.  (16) modules with 5 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
36998	14041-10003-15812	1 W WORLD WAY WEST	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	PIN	33.94461393	-118.39808495	CHANGES TO APPROVED SET OF PLANS.  PLAN CHECK FOR POWER ONLY.  RELOCATION OF TENANT CONDUIT STUB-OUTS FROM BOARD HD1 TO LD1 AND FROM HD2 TO LD2. CHANGES NOTED DELTA (-).  SCOPE OF REVISIONS AFFECTS ONLY SHEET T6C-E00-004.  (((Plan check for power and lighting.  Total area = 25, 595 sq. ft.Redevelopment of terminal 6 project.  Replacement of existing light fixtures, power outlets, equipment, low voltage devices, and primary facility electrical infrastructure.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
36999	16041-20000-03877	12045 W WATERFRONT DR SUITE 450	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	33.98209	-118.40611	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 450. 2165 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37000	19041-10000-31189	3660 W WILSHIRE BLVD	90010	10	132B193    63	5093019020	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.06155	-118.30505	energy pc for Tenant Improvement and Change of Use from Office to Restaurant. Area of scope 1119sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37001	15041-30001-42259	16513 W OTSEGO ST	91436	5	171B137   238	2259016025	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	12/31/2015 12:00:00 AM	ADDRESS	34.16278	-118.4929	Expedite fees only.     Addition of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37002	18041-10000-34450	15101 W SAN FERNANDO MISSION BLVD	91345	7	210B145    79	2664001022	A2-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	03/09/2020 12:00:00 AM		Permit Finaled	06/03/2021 12:00:00 AM	ADDRESS	34.27287	-118.45995	PLAN CHECK FOR T24 ONLY, CHANGE OF USE TO EDUCATIONAL FROM B-2. T.I. IMPROVEMENT: NEW LIGHTING, NEW POWER. NEW LOADS < 200A, TOTAL AREA: 3,255 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37003	15041-10000-14380	941 E 35TH ST	90011	9	115-5A209  87	5114016001	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Closed	06/08/2015 12:00:00 AM	ADDRESS	34.01191	-118.25916	PC for power. Temp power for usc, existing service. New 1200 A distribution board.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37004	12041-10000-16338	2655 N RUTHERFORD DR	90068	4	153A191    41	5580006031	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.11544	-118.31971	Plan check for new installation of 11.4KW roof mounted photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37005	19041-20000-00962	14601 W DEL PLAYA ST LOT 1	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.24792	-118.45044	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37006	15041-20000-01303	1950 S SAWTELLE BLVD	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.04129	-118.44377	PLANCHECK FOR T24 ENERGY ONLY.  LIGHTING ONLY. NO POWER. DENTAL OFFICE CORRIDORS ONLY AND STORAGE ROOM. 2013 SQFT. EMERGENCY FIXTURES EXISTING TO REMAIN. DESIGN BUILD BY B CONTRACTOR. [ INSPECTOR TO VERIFY ANY NON-LIGHTING ELECTRICAL WORK- REQUIRES PLANS WITH ENGINEERING DESIGN, SEAL AND APPROVAL]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37007	17041-10002-36500	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.12626	-118.21412	"DELTA ""1 and 3"" Changes to approved plans. Revised single line diagram, New subpanels, new circuits and a new Med. Voltage 175KVA, 4,800 Volt transformer. The total connected load is over 400A. Master application has been pulled and permits are under 17041-10000-36500. <<<FROM THREE EXISTING SWBDS, PROVIDE ELECTRICAL POWER TO ATHLETIC LIGHTING, IDF  ROOM, AND POOL EQUIPMENT BUILDING. OTHER BUILDINGS INCLUDE CULLEY GYM, DEMANDEL POOL DECK, AND MCKINNON TENNIS FACILITIES>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37008	10041-20000-23565	922 S LAKE ST	90006	1	130-5A203  66	5136006013	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Apartment			11/24/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	04/28/2011 12:00:00 AM	ADDRESS	34.05319	-118.28017	upgrade service to 600 A and new meters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37009	18041-10000-10010	19601 S HAMILTON AVE	90502	15	057B197    81	7351033023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.85319	-118.28624	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37010	16041-10000-27589	9301 N TAMPA AVE 59A-58	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	TITLE 24 FOR EXISTING BUILDING (TI FOR STARBUCKS).TOTAL (1690SQ. FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37011	14041-20001-31862	11938 W RUNNYMEDE ST #A & B	91605	6	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.20563	-118.39354	Fee for expedite only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37012	13041-20000-33386	13029 W VENTURA BLVD	91604	2	165B161   952	2375020018	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	33.9787	-118.31759	Change to lighting, new 600 amp service for an existing restaurant.  Full plan check for power and Energy.inspector to field verify existing panel reconnection, shall have a fully rated AIC rating greater then 26kA at that point.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37013	13041-10000-15184	6600 N TOPANGA CANYON BLVD 2066	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING FOR A TENANT IMPROVEMENT. SCOPE OF WORK LESS THAN 400 A. REMINDER: ALL TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37014	14041-10000-04472	5806-5816 W HAROLD WAY	90028	13	147A191    24	5545011010	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			02/18/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.0991	-118.3161	plan check for power and energy. NEW CONSTRUCTION OF A  4 STORY, 56 UNIT APARTMENT BUILDING; 3 FLOORS OF APARTMENT  TYPE V-A CONSTRUCTION  ON TOP OF  FIRST FLOOR PARKING AND ENTRY LOBBY OF TYPE I-A CONSTRUCTION.  NFPA 13 SPRINKLER.Fire alarm variance filed on 11/5/2014.BUILDING PERMIT 13010-10000-04237.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37015	16041-20001-28312	23233 W SATICOY ST #109	91304	12	186B093    85	2027005005	P-1VL, [Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM			PC Approved	01/20/2017 12:00:00 AM	ADDRESS	34.2084	-118.63348	01/20/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan and the power floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement/change of use from retail to massage parlor. Total lighting area = 1,138 sq. ft.Note: Building application has been generated under 16016-20000-18168	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37016	18041-10000-08159	6320 W SUNSET BLVD 2ND FLR	90028	13	147A187   143	5546015029	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.09783	-118.32747	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN AN EXISTING OFFICE IN THE 2ND FLOOR. TOTAL SQ. FT. 5350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37017	12041-20000-14794	19755 W VANOWEN ST #A-14	91306	3	183B117   835	2135022005	(T)(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	Space #14 tenant development.  Complete plan checkNote: core and shell plans approved under 09041-20000-13618	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37018	13041-10001-32376	844 W 101ST ST	90044	8	091-5A199 205	6054012039	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	33.94448	-118.29085	Expedited RSES plan check per applicant request. (((PV1, Install 3.75 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 15 modules Yingli YL250P-29b.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37019	16041-30000-18274	10011 S AVALON BLVD	90003	8	091-5A207 123	6063004031	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	33.94523	-118.26535	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,038 sq. ft.Note: Building application has been created under 16016-30000-12003	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37020	18041-20001-11977	7600 N BALBOA BLVD 108	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM			PC Approved	05/06/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	Revisions to approved set of plans.  Addition of sign circuit and sign lighting Title 24 forms to plans.  EM lighting detail change - all EM lights to be supplied by integral 90 minute battery backup.  Approval for delta-7 revisions only.(((FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT. FIRST TIME TENANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1453 SQ. FT.  B#18016-10000-09615)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37021	13041-20001-03760	17748 N ALONZO AVE PV-1	91316	5	165B129    66	2182026003	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Expired	05/20/2015 12:00:00 AM	PIN	34.15211497	-118.51932538	Addition of six extra panels. Plan check for PV system. Ground mount.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37022	13041-10000-13456	10960 W WILSHIRE BLVD	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.058	-118.44597	PLAN CHECK FOR POWER. INSTALLATION OF TWO CHILLERS. 222 KVA CHILLERS. SCOPE OF WORK > 400A (610A).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37023	16041-20000-15499	1528 E 16TH ST	90021	14	120A213   176	5129009022	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.02331	-118.24447	Plan check for new three-phase 1200A 120/208V service.  (SERVICE LOCATED AND RELEASED TO DWP AS ADDRESS : 1501 E 17TH ST UNIT A & B)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37024	17041-20000-34255	11051 W VICTORY BLVD	91606	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.18686	-118.37207	replace existing outdoor luminaires with new led.  plan check for outdoor energy only.  total square footage 300000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37025	10041-20000-13163	3551 S TROUSDALE PKWY 3rd Floor	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	34.02066	-118.28531	Changes from previously approved plans (10041-20000-05604).   general and emergency lights in multipurpose, kitchen, and restroom room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37026	15041-10000-13564	11301 W PICO BLVD	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM			PC Approved	06/17/2015 12:00:00 AM	ADDRESS	34.03517	-118.43924		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37027	17041-10001-44866	6101 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM			Corrections Issued	10/17/2018 12:00:00 AM	ADDRESS	33.93236	-118.39253	This is plan check only for changes to approved set, noted as Delta-1. The only scope of work is on single line diagram, sheet E0.04. Permit is covered under master permit.((REPLACE MCC CONTROL PANELS IN AN UPGRADED CARGO FACILITY OF KOREAN AIR.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37028	14041-20001-29393	514 S CATALINA ST	90020	10	135B197   816	5502022020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			10/23/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.06489	-118.29525	EXPEDITE PER APPLICANT REQUEST[PV2Install roof-mounted solar array on existing apartment building.System size: 22.8kW (11.4+11.4). Inverters have transformers.88 305W pv modules. 4 strings per inverter of 11 modules each.Interconnect with existing 400A MSP].	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37029	19041-30000-07910	601 S FIGUEROA ST 13th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is the 13th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 18,225 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37030	16041-20000-37477	1336 N GORDON ST	90028	13	147A191   187	5545014035	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			10/21/2016 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.09547	-118.31997	Plan check for power and energy. Project site is a new 4-story, 44-unit apartment building over 2 levels of below-grade parking. Work includes a 1,200-amp service and a total lighting area of 33,335 sq. ft.Note: Building application has been filed under 15010-10000-02290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37031	19041-20000-25841	5760 N WISH AVE	91316	6	174B133   147	2255022022	R1-1-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.17602	-118.50576	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6.64KW DC/5.584KW AC. SCOPE OF WORK INCLUDES (16) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37032	17041-20001-18343	5325 S COMPTON AVE 1-2	90011	9	108B209   453	5104009030	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Apartment			06/01/2017 12:00:00 AM			Reviewed by Supervisor	06/13/2017 12:00:00 AM	ADDRESS	33.99414	-118.24792	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.94 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37033	17041-20001-36582	340 S ARDMORE AVE 1-52	90020	10	135B193   379	5502001019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.06768	-118.3014	EXPEDITED PER APPLICANTS REQUEST. PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 46 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37034	14041-10004-27847	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	"02/11/2016Changes To an approved set of plans. Changes include the connection of temporary load. The loads connecting to ""MS2"" are in (E) panels ""EDS"", ""DSBG"" and DSBG-A"". 8/12/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  TEMPORARY POWER FOR BAGGAGE HANDLING.7/24/2015 PLAN CHECK FOR CHANGES TO SET OF PLANS DELTA 1 AND DELTA 2. RESHUFFLING OF LOADS AND RELOCATION OF PANELS. NO NEW LOADS HAVE BEEN ADDED. ((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX TERMINAL 1. CHANGING OF THE POWER DISTRIBUITION SYSTEM AND LIGHTING.))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37035	15041-20000-39192	1149 W 190TH ST	90248	15	060B197   546	7351028018	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	33.85848	-118.296	FULL PC. TI ON EXISTING COMMERCIAL BUILDING (VALOR HEALTHCARE, GENERAL PRACTIONER/PSYCHIATRY). CHANGE OF USE FROM OFFICE TO INTERIOR MEDICAL OFFICE. SCOPE INCLUDES NEW LIGHTING ON EXISTING PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37036	16041-20000-12899	7071 N VINELAND AVE	91605	2	183B173   142	2319002018	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Issued	05/04/2016 12:00:00 AM	ADDRESS	34.19929	-118.37051	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,910 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37037	15041-10001-32591	7809 N BOTHWELL ROAD	91335	3	189B117   774	2105006016	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	34.21248	-118.56137	EXPEDITE PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(26) MODULES(2) INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37038	15041-10000-21187	16027 W VENTURA BLVD STE 500	91436	5	168B141   538	2261022106	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.15641	-118.48225	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO A NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK IN SUITE 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37039	17041-10000-10030	5200 N LANKERSHIM BLVD STE 350	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 6593 SQ. FT. b#17016-10000-05357	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37040	15041-10000-05693	2055 S BARRINGTON AVE	90025	11	123B149   273	4262031012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.03581	-118.44934	few luminaires , new panelboard, new circuits and 16KVA UPS IN office spaceplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37041	19041-20000-29503	10934 W PEACH GROVE ST	91601	2	168B173   318	2421014027	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Apartment			07/30/2019 12:00:00 AM	12/01/2022 12:00:00 AM		Issued	12/01/2022 12:00:00 AM	ADDRESS	34.15891	-118.36916	Full plan check for power and energy. New three apartment building with 1000 amp service. T24 included, total square footage =  10,036sfbuilding application number 18041-20000-00193	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37042	17041-10000-40900	4020 S COMPTON AVE	90011	9	115-5A211 172	5117013006	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM			PC Info Complete	03/16/2018 12:00:00 AM	ADDRESS	34.00966	-118.25014	PC FOR REPAIR FIRE-DAMAGED PORTION (39,000 SF) OF (E) STORAGE BUILDING FOR t-24 ENERGY ONLY.SCOPE OF WORK INCLUDES INSTALLING NEW PANEL,  LIGHTS AND CIRCUITS.B#17016-10000-32766COMPLY WITH DEPARTMENT ORDER effective date04/19/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATECEIS 762561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37043	19041-20000-31319	23843 W ERIN PL	91304	12	189B089   502	2020033043	(T)RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.21152	-118.64729	Plan check for PV roof mounted system, PV system size: 14.4KW DC, 10.0KW AC with 40 PV Modules and 1 inverter(10.0KW)Fees $91.17 Due to California Senate Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37044	17041-20000-36376	9140 N MOONBEAM AVE	91402	6	198B153   870	2639031015	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.23668	-118.4428	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37045	17041-10000-37597	300 WORLD WAY l2-apron	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	Plan check for Title 24 only in existing storage space. Total area: 557 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37046	17041-10002-04640	20159 W RINALDI ST S5	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.27528	-118.57287	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  25, 26 & 28. CHANGES INCLUDE RELOCATING SITE/LANDSCAPE LIGHTING, ADDING NEW CIRCUIT FOR IRRIGATION CONTROLLER, REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, REVISING PANEL SCHEDULES,  AND SPECIFYING EGC CONDUCTORS ON THE FLOOR PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37047	19041-20000-24716	4718 W FRANKLIN AVE	90027	4	150B197   871	5589028007	R3-1	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Apartment			06/26/2019 12:00:00 AM	06/02/2021 12:00:00 AM		Issued	06/02/2021 12:00:00 AM	ADDRESS	34.10525	-118.29251	new apartment building 600 amps plan check for power and energy.3 story/ 6 unit/ typical units	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37048	12041-10000-26194	2610 N CANYON DR	90068	4	154-5A191 151	5580020015	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.11849	-118.31613	PV1  PLAN CHECK ROOF MOUNTED 6.54KW PHOTOVOLTAIC SYSTEM. TRANSFORMERLESS INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37049	14041-20000-01339	20530 W WYANDOTTE ST	91306	3	186B109   951	2113022011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.20299	-118.58108	PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37050	16041-20000-07536	550 S HOPE ST SUITE 255	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES, 1220 SQFT. SUITE 255	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37051	19041-10000-23943	18362 W OXNARD ST BLD. 3	91356	3	177B125   753	2157002134	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Issued	11/08/2019 12:00:00 AM	ADDRESS	34.17985	-118.53311	FULL PLAN CHECK FOR POWER AND ENERGYSCOPE INCLUDES NEW 800A SERVICE 120/208V- TOTAL NEW CONNECTED LOAD OF APPROX. 400A. TOTAL AFFECTED AREA 307 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37052	15041-20001-39673	7101 N OSO AVE #15	91306	3	183B113   925	2136007***	(Q)RD6-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Apartment			11/24/2015 12:00:00 AM			Reviewed by Supervisor	12/08/2015 12:00:00 AM	ADDRESS	34.19918	-118.57564	PV2, rooftop mounted solar on the Unit#15 apartement complex. 5kW AC system.   (24)modules #KU2656ZPA   (1)inverter: PVI-5000-OUTD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37053	14041-20000-31082	1046 S SERRANO AVE	90006	10	129B193   559	5080017085	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			11/07/2014 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.05119	-118.30618	Plan check for power and energy. New 4-story 20 unit apartment building. 1000A service. Indoor area - 16,583sqft, outdoor area - 5,835sqft. CRA clearance cleared under building permit. Fire alarm variance filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37054	19041-10000-00490	2829 N BROADWAY	90031	1	138A223    42	5204021029	C2-1	East Los Angeles				1998.00	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	PIN	34.07403352	-118.21198214	CONSTRUCTING NEW STORAGE AREAS FOR  ARCO MARKET- NEW LUMINAIRES AND CIRCUITSPLAN CHECK IS FOR TITLE 24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37055	16041-20001-26082	643 N RADCLIFFE AVE	90272	11	126B125   468	4412014047	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.04225	-118.53093	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 8.6kW with 25 AC Modules.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37056	13041-20000-15307	6310 W SAN VICENTE BLVD	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.06084	-118.36757	T24 FOR HIGH RISE OFFICE SPACE. SCOPE OF WORK ON THE 3RD FLOOR SUITE 330. TOTAL SQRFT 2496.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37057	18041-20001-37692	6244 N RANCHITO AVE	91401	2	177B153   228	2239008005	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM			PC Approved	10/18/2018 12:00:00 AM	ADDRESS	34.18445	-118.43548	Expedite per applicant requestPlan check for PV roof mounted system, system size: 18.72KW DC, 14.976KW AC with 52 PV Modules and 2 inverters(7.6kW and 10.0kW) connected to 400A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37058	17041-20001-29328	22111 W CAJUN CT	91303	3	183B101   867	2024012***	(T)(Q)RD2-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.2001	-118.60859	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (20) modules. PV system is interconnecting with a center-fed panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37059	15041-20000-06087	10141 N MEMORY PARK AVE	91345	7	204B145   623	2660013021	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.25483	-118.46406	Installation of new roof mounted solar PV array.  Total system size = 4.2 kWac.  Single inverter with 19 modules total (2 strings).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37060	18041-20000-11499	12041 N LONGACRE AVE	91344	12	216B125   407	2601031038	(Q)RE40-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Closed	03/07/2023 12:00:00 AM	ADDRESS	34.28981	-118.53099	Plan check for a PV1 roof-mounted PV system. System size is 13.7 kWac/15.6 kWdc and consists of (48) modules, (48) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37061	13041-10000-32162	12887 W RUNWAY ROAD UNITS 1-6-BLDG 1	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/26/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	33.97515	-118.42058	INSTALLATION OF A NEW FIRE ALARM SYSTEM for a 4 story residential building (Building 1). THIS IS BUILDING 1 OF 6. Building shares service with 5 other buildings on site. There are two building types for the site. Building 1 is plan type 6 ( SIGNIFYING 6 PLEX ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37062	15041-10000-23535	2237 W BANCROFT AVE	90039	13	147A209   270	5440018020	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.09673	-118.25589	PV1, INSTALL NEW 7.685 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSES. (29)MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37063	14041-10000-32457	12859 W WEIDNER ST	91331	7	213B161   554	2533024010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.28005	-118.41309	PV1 Roof mounted System size: 7.6kW with 34 modules(kyocera KD 200-60 F Series) and 1 inverter(Solaredge SE76000A-US-ZB-U)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37064	15041-20001-24516	22022 W CALLE MILAGROS	91311	12	210B101    73	2723005052	(T)(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.2681	-118.60693	revision to approved set of plans. change in location of inverter. permit inlcudes circuit for monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37065	17041-20000-16013	5261 N HARMONY AVE UNITS 1-12	91601	2	171B173   352	2416009015	[Q]R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM			Reviewed by Supervisor	06/21/2017 12:00:00 AM	ADDRESS	34.16669	-118.36668	PLANCHECK FOR POWER AND ENERGY.  NEW 12 UNIT TYPE V-A , 4-STORY APT.fire alarm variance has been submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37066	18041-20000-37508	11826 W SHELDON ST	91352	6	198B169    54	2538003030	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			PC Approved	10/02/2018 12:00:00 AM	ADDRESS	34.24137	-118.39062	ti to an existing commercial building.  adding new lighitng new controls to a new panel.  newly connected load <400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37067	17041-10000-07650	988 W SLAUSON AVE	90044	9	108B197  1460	6004001031	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	33.98898	-118.2912	PC for title 24. Interior and exterior renovation to an existing McDonald's restaurant. New lighting and power. Area: 4,080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37068	19041-20000-30152	901 S RIDGELEY DR	90036	4	132B181   472	5089026020	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.05884	-118.35209	Plan check for PV roof mounted and Energ Stroage System, PV system size: 12.21KW DC, 11.24KW AC with 37 PV Modules and 37 Microinverters, 1 Tesla PowerWall 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37069	14041-20000-01879	4156 N HAYVENHURST AVE	91436	5	165B137   400	2291013015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.14659	-118.49713	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING 30 MODULES. TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37070	19041-10000-49007	11811 W OLYMPIC BLVD	90064	11	123B149   409	4259023015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	08/26/2020 12:00:00 AM	ADDRESS	34.03315	-118.45057	FULL PLAN CHECK FOR A TI TO EISTING SCHOOL WITH THEATRE AREA. SCOPE INCLUDES NEW 45KVA TRANSFORMER, 2 NEW PANELS AND ADDITIONAL LOADS FOR LIGHTING AND RECEPTACLE. TOTAL  AFFECTED AREA IS 25436 SQ.FT BUILDING PERMIT #19016-10000-38256:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37071	19041-10000-30983	5805 E ARROYO DR	90042	1	150A229   145	5492007002	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.10568	-118.18924	PV1 NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3KWac/2520KWdc. SCOPE OF WORK INCLUDES 8 MODULES (HANWHA Q CELLS 315), A CENTRAL INVERTER (NINGBO GINLONG).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37072	13041-20000-10009	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Closed	06/04/2013 12:00:00 AM	ADDRESS	33.98645	-118.44148	Install 3 circuit breakers with shunt trip for elevators 4, 5, and 6 at various locations in the building, and install a new feeder from panel HLC to elevator #5..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37073	18041-10000-45105	380 WORLD WAY AMEX-LOUNGE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	"TI IN AN EXISTING ""AMERICAN EXPRESS"" LOUNGE IN TOM BRADLEY TERMINAL OF LAX. PLAN CHECK FOR POWER AND ENERGY. (((FEE ESTIMATE))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37074	15041-20001-36355	19645 W SHERMAN WAY BLDG 6	91335	3	183B117     7	2116001090	C2-1VL, R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.20129	-118.56157	EXPEDITE PER APPLICANT REQUEST. ((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (24) MODULES-CANADIAN SOLAR CS6P255P(1) INVERTERS-SUNNY BOY SA SB6000US-12(1) 125 SUBPANEL)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37075	17041-10002-12650	2330 N FLETCHER DR	90039	13	150A209   194	5438015056	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.10484	-118.25807	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGED NOTED DELTA 2 ON PLANS. CHANGE TO WALL SCONCE LIGHT TO REFLECT AS BUILT. UPDATED LIGHTING FIXTURE SCHEDULE AND T24 DOCUMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37076	15041-10000-26417	13132 W CREWE ST	91605	2	183B161   656	2327010013	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.19654	-118.41929	PV1 ROOF MOUNTED SYTEM FOR A SINGLE FAMILY HOME. (1) INVERTER: 11.4 KW, (48) MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37077	15041-20000-27757	9449 N BIANCA AVE	91325	12	198B129    34	2766019003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Closed	02/09/2016 12:00:00 AM	ADDRESS	34.24276	-118.5143	Plan check for a PV1 roof-mounted PV system. Work includes the addition of a 3 kWac system onto an existing 7.2 kWac system. New system consists of (1) inverter, (14) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37078	19041-10000-50645	11558 W HARTSOOK ST	91601	2	171B169   520	2354004043	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.16387	-118.38426	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 27 MODULES (AXITEC SOLAR 310) AND 14 MICROINVERTERS (APS YC600). SYSTEM SIZE IS 7.29KWAC AND 8.37KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37079	14041-10000-24545	5008 N TILDEN AVE	91423	4	171A151   222	2248008040	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			Reviewed by Supervisor	09/16/2014 12:00:00 AM	ADDRESS	34.16155	-118.44735	pv2 INSTALL 12240 W DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(48)MODULES: SUNIVA OPT 265-60-4-100(2) INVERTER(S): SMA AMERICA SB6000US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37080	17041-10000-15224	801 S BERENDO ST	90005	10	132B197   577	5094014021	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	08/18/2021 12:00:00 AM	ADDRESS	34.05753	-118.29435	Plan check for power and Title 24.  New 7-story low rise mixed-use apartment building with 2 subterranean parking levels. Ground floor retail with 6-story 98 total apartments.  New 3,000 amp 208/120 volt service.  17 typical units.  Project located in methane zone.  Total common area = 84,571 sq. ft.     Building permit #15010-10000-03362	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37081	19041-10001-08261	3203 N CANYON LAKE DR	90068	4	156B185    16	5577036013	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.12776	-118.32732	NEW 12.6KW ROOF MOUNTED PV SYSTEM WITH 40 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37082	15041-10000-37414	900 W TEMPLE ST 1-239	90012	14	133-5A211  94	5161001043	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	ADDRESS	34.06063	-118.24976	$0 final fee per senate bill 1222.PV2, ROOF MOUNTED SOLAR SYSTEM FOR AN APARTMENT BUILDING. 384 MODULES AND 4 INVERTERS. TOTAL SIZE IS 88.2-KW(326) WORLDWIDE AS6P305(1) FRONIUS SYMO 17.5 0-3 480V WYE(2) FRONIUS SYMO 24.0-3 480V WYE(1) FRONIUS SYMO 22.7 -3 480V WYE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37083	18041-10000-36464	2400 W WASHINGTON BLVD	90018	10	126B189   922	5073028009	[Q]C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Issued	09/25/2018 12:00:00 AM	ADDRESS	34.03972	-118.31463	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37084	11041-10000-24681	12415 N HENZIE PL	91344	12	219B133   335	2608016009	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2011 12:00:00 AM	01/04/2012 12:00:00 AM		Permit Finaled	04/16/2012 12:00:00 AM	ADDRESS	34.29748	-118.51192	New 11KVA rooftop photovoltaic system for a single family residence.   48 Panels, 1 inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37085	14041-20000-28799	11430 W BURBANK BLVD	91601	2	174B169   839	2350004033	C4-1, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			10/17/2014 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.17184	-118.38	NEW MIX USE APARTMENT BUILDING (2) SERVICES (1) 2000 AMP SERVICE (1) 1200 AMP SERVICE FIVE FLOORS WITH ONE UNDERGROUND PAKING LEVEL.  125 UNITS.  PLAN CHECK FOR POWEER AND ENERGY.Note: Variance to separate fire alarm plans submitted on 10/17/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37086	13041-10001-35994	11341 W COHASSET ST	91352	2	186B173   466	2315016026	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.20675	-118.37839	Expedited RSES plan check per applicant request. {{PV1, Install 3 kW DC roof-mounted solar array for a 2-story house, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (12) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37087	14041-10000-15275	624 S HILGARD AVE	90024	5	135B153    93	4360015034	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.06876	-118.43894	Plan check for energy only. BLDG#:14016 10 10259: ALTERATION TO (E) 3-STORY SORORITY HOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37088	15041-10000-24068	1500 W PACIFIC COAST HWY Bldg I	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 15 unit apartment with garage, 43 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37089	17041-20000-20814	1026 S SANTA FE AVE 2ND-3RD FLR	90021	14	123A217   238	5166005004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.03072	-118.2298	Plan check for energy only. CHANGE OF USE OF THE 2ND AND 3RD FLOORS FROM MANUFACTURING TO OFFICE. New lighting (incl. emergency) - 12,352sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37090	19041-20000-52110	10555 W BLOOMFIELD ST	91602	4	165B177   462	2424011004	R4-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM	06/14/2021 12:00:00 AM		Permit Finaled	08/14/2023 12:00:00 AM	ADDRESS	34.14972	-118.36116	Plan check for power and energy for 1600A Service 63 sub-panels. Total area: 41255 sq ft. PER BLDG PERMIT#19010-20000-04524**********************************Building work description:  4 STORY 57 UNIT APARTMENTTWO STORY BASEMENT GARAGE (TYPE IA ) (AFFORDABLE HOUSING  INCLUDING 6 VERY LOW INCOME UNITS PER LAMC 12.22A25(C)**********************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37091	14041-10000-27245	11110 W TUXFORD ST	91352	6	195B173   126	2408031007	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.23296	-118.37316	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 2572 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37092	14041-20000-35606	444 S FLOWER ST 16th Fl	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM			PC Approved	12/24/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	T.I. to existing high rise building.  Install general/emergency lighting in the elevation lobby, corridor and restrooms.Note: Permit is under a different application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37093	18041-20000-46480	914 W AVENUE 37	90065	1	147A221   161	5454019037	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	Yes	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.09708	-118.21898	PV1.  Install 5.94 kW roof mounted grid tied PV system with 13.2 kWh energy storage system.   (18) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37094	15041-10000-22110	7325 N VARNA AVE	91605	2	186B157   482	2328026004	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.20364	-118.42486	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37095	14041-20000-13669	9233 W SWALLOW DR	90069	4	150B169  1257	5561009022	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.10482	-118.38956	New 2-story single family dwelling over basement with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37096	10041-10001-23566	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM			PC Approved	11/18/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions to permitted set of plans- a 100Asubpanel of panel 1LA; CONVEYOR TC1  AMPERE RATING INCREASED FROM 20a TO 199a with adjusting feeder size and conduit size and recalculating vd AND AND FEEDER LENTH; CORRECTED THE IMPEDANCE OF THE 15KVA TRANSFORMERS;Recalculated short circuit values using the correct value (59201 A) of the short circuit at the service.(((((((New work at Delta Airline Terminal 5, remodel of the FIS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37097	12041-10001-28962	905 E 2ND ST	90012	14	129A215   180	5163004006	(T)(Q)C2-2D	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			12/17/2013 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.04729	-118.23499	Changes to approved set.  Removal of drip loop sections, rerouting of main service feeder and distribution board for under slab building, and other changes to distribution equipment and system.  Initial revised plan set submitted without numbered delta changes - applicant has agreed to provide revised plan set with delta changes in addition to letter enumerating changes to approved set (included in submittal).  (((5-stories mixed use building over 2 levels basement; 320-Apts;)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37098	17041-20000-10053	5670 W WILSHIRE BLVD 1036	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	Commercial office TI in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37099	19041-20000-28652	9307 N TAMARACK AVE pv1	91352	6	198B165   172	2629012023	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.23802	-118.3973	$0 fee due to AB1414.pv1install roof  mounted pv system sized 19.4KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37100	16041-10000-16867	8400-8420 N BALBOA BLVD WEST	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.22376	-118.50243	NEW single story Commercial build. 1600A UGPS ( None Methane Zone per Zimas). PC for Power and Energy. Total area: 495 sq.ft. (indoor) + 210,020 sq.ft. (outdoor).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37101	16041-10000-19192	1840 S CENTURY PARK EAST 13TH	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE LOCATED ON THE 13TH FLOOR. TOTAL AFFECTED AREA IS 14285 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37102	16041-10001-27157	1875 S CENTURY PARK EAST #950	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.06115	-118.41457	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. ADDED RECEPTACLES AND LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37103	13041-10000-22911	10523 N WHITE OAK AVE	91344	12	207B129   824	2733008004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM			Plans on Hold	08/29/2013 12:00:00 AM	ADDRESS	34.26206	-118.52004	PV1. ROOF MOUNTED SOLAR ARRAY. INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER, UNGROUNDED SYSTEM. SYSTEM SIZE: 10.78kW. 2 TPOWER ONE AURORA INVERTERS ( 6KW AND 3KW) .44 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37104	16041-20000-44979	15760 W VENTURA BLVD Ste 1400	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	Existing office remodel in commercial highrise building.  All circuits existing.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37105	16041-20000-36547	14401 W SYLVAN ST	91401	6	178-5A151 121	2240002015	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.1848	-118.44665	Plan check for a PV2 roof-mounted PV system. System size is 30 kWac and consists of (3) inverters, (96) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37106	18041-10000-32689	334 W 33RD ST BUILDING-#2	90007	9	120A203   218	5122020002	[T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			Reviewed by Supervisor	09/05/2018 12:00:00 AM	ADDRESS	34.02171	-118.27672	FULL PLAN CHECK FOR (2) BUILDING WITH (2) APPLICATION UNDER (1) PLAN OF THE SAME LOT. THIS APPLICATION IS FOR BUILDING #2. 1 OF THE 2 NEW 2-STORY LIGHT CLOTHING MANUFACURE BUILDING. THE (2) BUILDINGS ARE SUPPLIED BY (1) 800-AMP SERVICE WITH 120/240V 2-PHASE 4-WIRE SYSTEM.1ST BUILDING #: 18041-10000-32691BUILDING REFERENCE #: 16010-10000-02095	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37107	15041-10000-08750	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.22149	-118.43179	TI TO EXISTING TWO STORY MEDICAL OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS. NO PATIENTS CARE AREAS NOR CRITICAL CARE AREAS. PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK TO BE PERFORMED IN THE FIRST FLOOR. TOTAL SQ FT. 303	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37108	11041-10000-27051	12350 W ADDISON ST	91607	5	168B165    34	2356025044	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.16077	-118.40257	Plan check 7.68KW roof mounted Photovoltaic system. single family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37109	15041-20000-18571	12704 W WOODGREEN ST	90066	11	114B153   909	4246003015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.00736	-118.44222	Plan check for PV roof mounted system. System size: 3.8kW with 14 modules and 1 inveter (3.8kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37110	14041-10000-15403	525 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR FAMIMA STORE. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. 1622 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37111	15041-20001-11157	16901 W NAPA ST	91343	12	195B133   508	2689018032	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Apartment			04/14/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	34.22679	-118.50046	Expedite per applicant request*******Plan check for PV 26kW system roof mouned with 2 inverter(CANADIAN SOLAR CS6X-305SSP) and 120 modules(canadian solar cs6x-305sp) and 3 combiner boxs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37112	17041-20000-40683	10055 N WYSTONE AVE	91324	12	204B121   433	2729004013	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.25332	-118.54723	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (37) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37113	16041-10000-08653	700 S FLOWER ST 23RD FL	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	T-24, PC FOR ENERGY. TI FOR NEW RESTROOMS & HALLWAY ON THE 23RD FLOOR OF AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1550 SQ, FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37114	13041-10000-36316	10210 N OAKDALE AVE LIBRARY	91311	12	204B113   213	2726008001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.25596	-118.56656	PLAN CHECK FOR POWER AND ENERGY. CONSTRUCT NEW ADDITION TO EXISTING LIBRARY AND CLASSROOMS.  2 OF 2. FEES FOR ENERGY CHARGED UNDER 13041-10000-36315BUILDING PC # 13010-10000-05228	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37115	14041-10001-24970	10535 N LANGMUIR AVE	91040	7	207A193   498	2556024029	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.2607	-118.30888	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. {{PV1, INSTALL 4.335 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(17) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37116	10041-10000-01354	2115-2119 N HILLHURST AVE	90027	4	150B197   125	5590003037	C4-1D	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM			PC Info Complete	01/26/2010 12:00:00 AM	ADDRESS	34.11039	-118.28764	New 600 A service drop and switchboard for a restaurant and two panels for the other tenants.  Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37117	15041-20001-19344	9335 N RESEDA BLVD STE 100	91324	12	198B125   179	2763004003	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			12/14/2015 12:00:00 AM			PC Approved	12/14/2015 12:00:00 AM	ADDRESS	34.24004	-118.53628	12/14/15Changes to an approved set. All Changes made under delta 1. Scope includes adding/removing outdoor lighting. (((Plan check for change of use from office to Medical space in existing building. 600A Service, total area: 12,700SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37118	11041-10000-23809	330 S LA CIENEGA BLVD	90048	5	138B173   831	5511032047	C2-1VL-O, P-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM	11/07/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.07282	-118.37627	New fire alarm system for an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37119	17041-10000-21281	2700 N CAHUENGA BLVD EAST	90068	4	154-5A185   7	5577010***	RE15-1-H	South Valley	Hollywood	Hollywood Hills West, Hollywood United	YES	1897.01	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.11804	-118.33687	one for one replacement of 13 light fixtures in parking lot.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37120	17041-10000-45508	2810 E WHITTIER BLVD	90023	14	123A223   177	5189004019	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.0315	-118.20975	PC FOR ROOF MOUNTED PV ON COMM. BUILDNG. SYSTEM SIZE 56.KWDC AND 53.3KWAC. SCOPE INCLUDES 162 MODULES WITH 81 OPTIMIZERS AND TWO CENTRAL INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37121	17041-20001-01476	2211 W HILL DR	90041	14	163-5A221  76	5671002002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.143	-118.21427	expedite per applicantpv1install roof mounted pv system sized 11.4kw interconected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37122	19041-10000-31167	400 WORLD WAY Space 4C	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	01/06/2020 12:00:00 AM		Permit Finaled	10/18/2020 12:00:00 AM	ADDRESS	33.94221	-118.40701	T-24 FOR TENANT IMPROVEMENT IN EXISTING  RETAIL SPACE  includes prepackage food  ON LEVEL 3.  Husson News. TOTAL AFFECTED AREA IS 2,227SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37123	16041-10001-01493	3526 N MARMION WAY	90065	1	144A223   355	5446025013	[T][Q]CM-1VL	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Apartment			12/15/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.08726	-118.21354	CHANGES TO AN APPROVED SET OF PLANS UNDER DELTA 1 REVISIONS.CHANGES INCLUDE SPEC. NOTES, AND DECREASING (7) HORNSTROBE SIZES FROM 185cd to 115cd. PLAN CHECK ONLY PROJECT UNDER EXISTING APPLICATION 16041-10000-01493.  ---------------PC FOR A NEW FIRE ALARM SYSTEM TO A NEW 4 STORY 49 UNIT APARTMENT BUILDING OVER ONE LEVEL SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES 1 FIRE ALARM PANEL, 1 COMMUNICATION PANEL, AND 177 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37124	17041-20000-14003	6856 N WISH AVE	91406	6	183B133   796	2230003007	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.19544	-118.5068	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37125	14041-10000-06384	7820 N AMPERE AVE	91605	2	189B161   809	2303014049	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Expired	05/05/2016 12:00:00 AM	ADDRESS	34.21255	-118.41781	PV1, INSTALL 8.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A & PV1-5000-OUTD-S-US-Z-A(34) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37126	12041-10000-07022	2407 S ORANGE DR	90016	10	123B181   421	5062024039	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2012 12:00:00 AM	05/18/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.03549	-118.35196	Plan check for new roof mounted 6.58KW photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37127	15041-10000-35414	606-610 W 47TH ST	90037	9	112-5A201 329	5018027021	RD2-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	Apartment			10/22/2015 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.00036	-118.28441	ADDING NEW PLUGS FOR AC UNITS IN TWELVE UNITS. PLAN CHECK FOR POWER ONLY.  PLAN CHECK REQUESTED PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37128	15041-20000-15778	10131 N OWENSMOUTH AVE	91311	12	204B105   502	2747015058	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.25521	-118.60181	Plan check for PV roof mounted system. System size 8.8kW system with 26 modules and 2 inverters(SB3800TL AND SB500TL) connected to load center 100A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37129	19041-20000-46352	836 N AVALON BLVD	90744	15	030B205   204	7423003900	OS-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	33.78088	-118.26231	100A 240/120V 1ph-3w service, panel, and lighting for outdoor recreational area.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37130	15041-10000-15918	922 E PICO BLVD	90021	14	123A211   242	5132018009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			Reviewed by Supervisor	07/17/2015 12:00:00 AM	ADDRESS	34.0308	-118.24981	pc for power and energy. core and shell. commercial building. not highrise. total area 4705 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37131	14041-20000-15214	14006 W RIVERSIDE DR #27	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLAN CHECK FOR T24 ENERGY ONLY.  IN AN EXISTING SHOPPING CENTER UNIT 27.  400 SQUARE FEET.  FIXTURE FOR FIXTURE EXCHANGE NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37132	12041-10000-07014	1455 N ROBMAR DR	90210	5	147B161   250	4355015068	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.09731	-118.41541	Plan check for new roof mounted 10.81KW photovoltaic system for single family dwelling. Existing 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37133	18041-20000-40359	1990 S BUNDY DR Ste 460	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.03419	-118.45559	Tenant improvement to (E) commercial high-rise office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37134	12041-20003-28770	15815 W MONTE ST	91342	7	225B141  1525	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.31113	-118.47563	Modification to previously approved set of plans.<<<<first tenant commercial>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37135	19041-10000-01226	459 S HARTFORD AVE	90017	1	132A207    95	5153024009	CW    R5(CW)-U/6	Central	Westlake	Westlake North		2091.03	Electrical	Electrical	Apartment			01/23/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	10/28/2021 12:00:00 AM	ADDRESS	34.05708	-118.26381	Full plan check for a  7 story , 101 unit affordable housing, over 1 level parking space.  Scope includes a 2500-Amp, 120/208V, 3ph, 4W, 68KAIC per LADWP WMIS service with (8) typical units.B# 18010-10000-03723	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37136	13041-20000-10174	1800 S AVENUE OF THE STARS #700	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.06095	-118.41786	Change to lighting, receptacles, loads to an existing high-rise office building on three floors.  Load is less than 200 amps for work on all three floors per applicant.  Plan Check Only for Energy, with Emergency lighting for the 7th Floor.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37137	12041-10000-06590	810 S SPRING ST	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.04268	-118.25375	Plan check power and energy TI restaurant (Terroni Restuarant) on first floor of an high rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37138	19041-10000-09286	5053 E LINCOLN AVE	90042	1	156A225   376	5477001016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/06/2021 12:00:00 AM	ADDRESS	34.12035	-118.2053	POWER AND ENERGY PC FOR NEW 2 STORY MIXED USE BUILDING. SCOPE INCLUDES 2 NEW 200A SERVICES. TOTAL AFFECTED AREA IS 3943 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37139	19041-10000-23117	6636 N MELBA AVE	91307	12	180B093   338	2036003027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.19084	-118.63339	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING (20) MICRO INVERTERS. TOTAL SYSTEM SIZE IS 6.2 KWDC AND 5KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37140	18041-10000-11613	3321 S LA CIENEGA BLVD	90016	10	120B173   176	4205033007	(T)(Q)C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			04/13/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.0275	-118.3723	Temp power for a mix use building. Scope of work includes a new 3000A, 277/480, 3PH, 4W Temp Service. Switchboard contains (2) Crane Lifts, (3) manlifts and 10 distribution panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37141	12041-10000-07714	8500 W BEVERLY BLVD 711	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM			PC Approved	04/04/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	REMODELING OF RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37142	14041-20000-14075	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.03497	-118.45709	Remodeling of single-story commercial office building on campus.  Existing service equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37143	19041-20002-07931	639 N NORTH BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	34.05972	-118.2398	Revisions to approved plans.  System redesigned, reduction in module quantity and inverter types/ratings.  New system size is 164.25 kW DC / 150.08 kW AC CEC, with (450) 365W modules, (4) 33.3 kW inverters, and (1) 20 kW inverter.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37144	17041-10000-34106	832 N COLE AVE	90038		141B185   109	5533028002							Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			Reviewed by Supervisor	11/03/2017 12:00:00 AM	ADDRESS	34.0862	-118.32971	Plan check Expired on 03/22/2019.  Updated to plan check only on 12/16/2019 FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM OFFICE/WAREHOUSE TO BANQUET HALL. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS,  AND NEW LIGHTS.  A-OCCUPANT LOAD > 100. TOTAL AFFECTED AREA IS 19723 SQ. FT. B#16016-10000-13446	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37145	14041-10000-21668	8511 W BEVERLY PL	90048	5	138B173   350	4337012069	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.07669	-118.37705	Plan check at counter for methane gas control system for a multi-story school building with subterranean parking. 1 panel, 25 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37146	17041-20000-22423	10900 W WILSHIRE BLVD FLOOR 10-11,12,14	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	01/07/2018 12:00:00 AM	ADDRESS	34.05848	-118.44419	PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT BUILD OUT OF FLOORS: 10,11,12 AND 14.building permit # 17016-10000-17860	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37147	12041-10000-30149	515 S FIGUEROA ST suite#1470	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM			PC Approved	12/14/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	Ti in an existing office Bldg. EPC is for T24. (14th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37148	17041-30001-01171	13767 W FOOTHILL BLVD	91342	7	225B153   444	2509015007	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	11/24/2017 12:00:00 AM	ADDRESS	34.31003	-118.43331	05/30/17Changes to an approved set of plans. All changes are clouded under delta 2. Changes include relocating electrical panels on the floor plans, removing/replacing lighting fixtures for indoor/outdoor, adding daylight controls for skylights, revising title 24 calculations, revising panel schedules, and revising load calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37149	14041-20000-26976	2625 S KENWOOD AVE	90007	8	123B197  1036	5054005005	R2-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM			Corrections Issued	02/11/2015 12:00:00 AM	ADDRESS	34.03195	-118.29932	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW.(1) PowerOne PVI-3.8-OUTD-S-US-A transformerless inverter(12) SunPower SPR-E20-327 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37150	10041-10000-16365	5070 W WILSHIRE BLVD	90036	4	132B181    40	5507027024	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.0619	-118.3402	Install a new Filre Alarm System in a new 3 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37151	11041-10000-09825	109 N FAIRFAX AVE	90048	5	138B177   554	5511001007	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM	05/13/2011 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	PIN	34.07471502	-118.36175869	T24 lighting plan check for remodeled restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37152	17041-10000-15968	1014 N WESTERN AVE	90029	13	144B193   933	5536022012	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM			PC Info Complete	05/12/2017 12:00:00 AM	ADDRESS	34.08893	-118.30893	TITLE 24 ONLY FOR TI (CHANGE OF USE FROM RETAIL TO DAYCARE FACILITY).TOTAL SQ FT. 1810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37153	17041-10000-32980	14303 W FRIAR ST	91401	6	180B153  1178	2240012012	[Q]R3-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			Reviewed by Supervisor	09/27/2017 12:00:00 AM	ADDRESS	34.18578	-118.44453	** (N) 4 STORY, 30 UNIT APARTMENT BUILDING (40,000 SF) 3 STORY TYPE V OVER 1 STORY TYPE I; AFFORDABLE HOUSINGBuilding# 17010-10000-03377PC for power and energy for new 3 story apartment building over one story of parking. Installing new 1600 A 120/208 V service. PC to request T24 forms and add to fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37154	15041-10001-43028	17383 W SUNSET BLVD A-310	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	03/03/16Changes to an approved set of plans. Changes include removing/replacing lighting fixtures.(((INTERIOR TENANT IMPROVEMENT TO (E) OFFICE.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37155	17041-20000-46502	3465 W 6TH ST	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.06373	-118.29761	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING FOR CHAPMAN PLAZA PARKING AREA. 16641 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37156	10041-20000-04558	15001 W VENTURA BLVD	91403	5	168B145  1029	2264016001	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	03/23/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.15293	-118.45974	CONVERT 700 SF OF STORE TO YOGURT AND PASTRY SHOP. NO DINE-IN SEATING. Doing lighting and some power. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37157	14041-10001-25056	1133 S HOPE ST	90015	14	127-5A207 285	5138014006	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.0416	-118.26394	Plan check only for significat changes to original set.  Remove of P3 parking level and miscellaneous Changes. New building high rise 28 story mixed use commercial and residential Note: Plan set to be review and stamp as RTI under master application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37158	11041-10000-01143	732 E 10TH ST Unit 105	90021	14	124-5A211 354			Central				2260.02	Electrical	Electrical	Commercial			01/20/2011 12:00:00 AM			PC Info Complete	01/24/2011 12:00:00 AM	ADDRESS	34.03504	-118.25099	Plan check for electrical and T-24 for space 105.  First tenant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37159	12041-10000-12624	102 BERTH	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	PIN	33.74075762	-118.28191984	Port of LA, Berth 102 Rear Backland.  Install 8 @ 100' light pole and six 4,160 Volt pieces of equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37160	16041-10007-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	DELTA 11 CHANGES TO PERMITTED SET OF PLANS: EMERGENCY LOAD CALCULATIONS REVISED TO INCLUDE FREIGHT EEVATOR TO SHOW GENERATOR IS RATED FOR ALL EMERGENCY LOADS ((((((((CHANGE OF USE OF OFFICE BUILDING TO HOTEL. FULL PLAN CHECK FOR POWER AND ENERGY. FULL 12 STORY TI. BUILDING IS HIGHRISEFIRE ALARM VARIANCE HAS BEEN FILED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37161	17041-20000-07363	301-319 N GLENDALE BLVD SOUTH BLDG	90026	13	136-5A207 349	5159020024	C2-1VL	Central	Westlake	Greater Echo Park Elysian	Yes	2083.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Issued	09/12/2017 12:00:00 AM	ADDRESS	34.06582	-118.26051	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT AND SERVICE UPGRADE.  PART 1 OF 2SOUTH BLDG301-319 GLENDALE NORTH BLDG325-345 GLENDALE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37162	19041-20000-53762	6420 W WILSHIRE BLVD 1910	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.06365	-118.36922	Power and lighting for commercial highrise tenant space improvements.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37163	14041-20001-02089	8011 N TROOST AVE	91605	6	189B169   199	2311005022	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	ADDRESS	34.21605	-118.38644	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. USING SOLAR OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37164	16041-20000-23265	6431 N INDEPENDENCE AVE	91367	3	180B109   592	2149003039	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.18737	-118.59079	$0 permit fee is per State Senate Bill SB-1222. Plan check for a PV2 roof-mounted PV system. System size is 75 kWac and consists of (5) inverters, (255) modules, (5) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37165	18041-10000-11521	7003 N RESEDA BLVD	91335	3	183B125   551	2126008020	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.19785	-118.53624	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37166	18041-30000-10431	13209 W MOORPARK ST	91423	4	165B157   317	2360030039	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.15049	-118.42075	Plan check for new fire alarm system 6 units  4 story appartment. Total new fire alarm devices: 56 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37167	14041-20000-08487	225 S GRAND AVE SUITE 118	90012	14	132A211    90		[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.05388	-118.25078	"New restuarant.  Install new 800A equipment.  Plan check for power and energy.inspector to field verfiy the use of emergency inverter to supply power to ""bug eye fixtures"". please call plan check engineer during inspection of emergency system."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37168	17041-20001-32780	8360 N ETON AVE	91304	3	192B105   528	2779013022	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.22124	-118.59493	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37169	16041-10000-30095	14834 W BURBANK BLVD	91411	4	174B149   869	2249028015	[T][Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.17189	-118.45649	Plan check for Title 24 only in existing space neil salon. Total area: 870 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37170	19041-20000-49207	18840 W VENTURA BLVD	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	05/05/2020 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.17186	-118.54425	NEW ROOF MOUNTED 84.18KW DC PV SYSTEM WITH 244 @ 327WPV PANELS 122 OPTIMIZERS AND 2 @ 43.2KW INVERTERS ON A COMMERCIAL BULDING.Fees $0.00 due California Senate Bill 1222 AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37171	18041-10000-08327	122 JAPANESE VILLAGE PLAZA MALL	90012	14	129A215    54	5161017033	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Issued	04/30/2018 12:00:00 AM	PIN	34.04880184	-118.23983917	PLAN CHECK F0OR ENERGY ONLY T24 FOR RESTUARANT TI. SCOPE INCLUDES INSTALLING NEW LIGHTS IN EXISTING SPACE (WITH (E) LIGHTS),  ADDITIONAL AC EQUIPMENT AND RECEPTACLES. TOTAL AFFECTED AREA 3171 SQ.FT. B#16016-10000-10634	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37172	18041-10000-14768	16830 W SAN FERNANDO MISSION BLVD	91344	12	210B133   998	2683028038	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.27181	-118.49871	Plan check for T24 only, install new lightings and receptacle in Teller area, new lighting loads will connect to existing circuits. Total area: 371 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37173	16041-20000-14167	116 N VISTA ST	90036	5	138B181   767	5512011022	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.07417	-118.35207	Plan check for a PV1 roof-mounted PV system. System size is 5.8 kWac and consists of (18) AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37174	19041-20000-48070	649 N HARVARD BLVD	90004	13	141B193   645	5521005018	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Apartment			11/21/2019 12:00:00 AM			PC Info Complete	06/07/2023 12:00:00 AM	ADDRESS	34.08306	-118.30471	FULL PLAN CHECK FOR NEW 800A SERVICE, A 800A MDP, A 225A PANEL, (18) SUB PANELS, A 25HP ELEVATOR, (2) 9 KVA EV CHARGERS, AND T24. TOTAL SQUARE FOOTAGE = 15521 SF.****PER B# 19010-30000-06483: New 5-story, 16 units apartment building - 4 story type III-A with roof top deck, 1st floor parkimg garage type I-A and 1-level basement garage type I-A utilizing TOC tier 2 - (2 extremely low income)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37175	09041-10003-19509	7660 W SUNSET BLVD	90046	4	147B177  1009	5550030001	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM			PC Approved	11/03/2010 12:00:00 AM	ADDRESS	34.09787	-118.3566	REVISIONS TO APPROVED SET OF PLANS-POST-SUPPORTED LUMINAIRES FOR HARDSCAPE ARE REDUCES ;UPDATED THE LIGHTING FIXTURE SCHEDULE;REVISED ENERGY COMPLIANCE FORMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37176	15041-20000-01897	2734-2760 N CLARAY DR club house	90077	5	156B149    56	4379005***	RE15-1-H-RPD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.1224	-118.44717	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 2ND FLOOR LOUNGE. 1346 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37177	14041-20000-12431	6554 N BONNER AVE	91606	2	180B173   554	2336003002	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.18993	-118.37358	PV1,  3.5kw roof-mounted PV system with (14) module,  1 transfomerless  inverter and 1 optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37178	13041-10001-30473	1891 N ACADEMY DR	90026	1	141B213    20	5415005902	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	34.08305	-118.2417	((5/15/2015- CHANGES MADE TO APPROVED SET. CHANGING FIXTURE TYPES FROM EXPLOSION PROOF TO NON EXPLOSION PROOF. USE OF SPACE HAS BEEN CHANGED FROM H-3 TO S1 PER BUILDING PLAN CHECK APPROVAL))NEW 2 STORY LAPD ACADEMY TRAINING FACILITY. PLAN CHECK IS FOR POWER AND ENERGY.NOTE: FIRE ALARM PLAN APPROVED UNDER 13041-10000-35522	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37179	18041-20000-28988	1633 N LA BREA AVE	90028	4	147B181  1177	5548008***	C4-1VL-SN, R4-1VL	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.10068	-118.34528	Plan check for Title 24 Energy only in existing space T.I. studio. Total area: 2606 sq ft. 18016-10000-21328	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37180	17041-10000-24593	10049 S LOU DILLON AVE 101-202	90002	15	091-5A215 217	6046019917	OS(UV), RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	05/04/2021 12:00:00 AM	PIN	33.94622917	-118.23474955	New, 3-story, 3-unit apartment building. 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37181	14041-10000-35081	9020 N RESEDA BLVD SUITE 102	91324	12	195B125    51	2769001031	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Closed	07/27/2018 12:00:00 AM	ADDRESS	34.2346	-118.53587	Energy plan check for a restaurant T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37182	10041-10000-18754	515 S FIGUEROA ST 19th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM			PC Info Complete	09/21/2010 12:00:00 AM	ADDRESS	34.05199	-118.25764	Ti in an existing office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37183	15041-20001-30141	10201 W PICO BLVD Bldg 32	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	PIN	34.05182951	-118.41257696	Expedite fees only.  Installation of new commercial roof mounted solar PV array.  Total system size = 56 kWac.  Two inverter system with 208 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37184	13041-10000-00401	7046 N DARBY AVE	91335	3	183B125   420	2125004025	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM			PC Approved	01/07/2013 12:00:00 AM	ADDRESS	34.19882	-118.53336	ti of garage area for new lighting for ambulance parking. this is a parking garage and auto repair. about 3080 sq ft. t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37185	17041-20001-31075	13856 W ALDERGROVE ST	91342	7	231B153    95	2582007024	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.32628	-118.43574	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37186	17041-10000-11597	333 S GRAND AVE 23RD FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	TI TO 23RD FLOOR. NEW OFFICES. LOAD GREATER THAN 400A. PC FOR POWER AND ENERGY.***VARIANCE FILED FOR EXISTING LOAD CALCULATION PER 220.87. APPLICANT HAS UP TO 8/11/2017 TO RETURN AND PROVIDE NECESSARY METER READINGS FOR PANELS SW-19A AND SW-24B. IF APPLICANT FAILS TO RETURN OR CALULATIONS AFFECTS THE CALCULATED LOAD, THE PC SHALL BE CONSIDERED VOID AND A NEW PC SHALL BE REQUIRED.**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37187	19041-10000-53539	13073 N NORRIS AVE	91342	7	222B145   124	2506014010	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.30695	-118.45935	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 13  (PANASONIC VBHN330SA) MODULES, 13 (SE P400) POWER OPTIMIZERS, 1 SE (SE3800-H-US) CENTRAL INVERTER, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE: 4.29KW DC, 3.80KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37188	14041-10000-13823	607 N ARDMORE AVE	90004	13	141B193   872	5521007012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			Reviewed by Supervisor	06/13/2014 12:00:00 AM	ADDRESS	34.08196	-118.30186	PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37189	17041-10000-44523	11321 S LA CIENEGA BLVD	90045	11	087B173   126	4129038026	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	33.93165	-118.37022	Remove HID fixtures and replace with new LED fixtures  T-24 only.TOTAL SQ.FT 84500	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37190	13041-10000-12122	2322 W SLAUSON AVE	90043	8	108B189  1391	4005025001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	33.9889	-118.31937	Addition to existing 2-story mixed-use building plus remodel of existing space.  First floor retail (laundromat), second story apartment units.  New 600A service and distribution network.  Power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37191	15041-10000-00690	11915 S BELHAVEN ST	90059	15	084B209   756	6084020027	RD2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	33.92398	-118.25572	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Pulling permit in person because of B contractor license. Cannot pull online.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37192	10041-20000-22416	333 S HOPE ST 33rd Floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check T-24 Energy general/emergency lighting TI on 33rd Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37193	12041-10000-30676	601 S FIGUEROA ST 7TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	02/06/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING FOR TI ON THE ENTIRE 7TH FLOOR. HIGH RISE (ON GENERATOR). USING AREA CATEGORY ON 1697 SQ FT (<30,000). (NEW CONNECTED LOAD <400A)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37194	17041-10000-42482	304 S BROADWAY #315&320	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.05076	-118.248	T-24 PC FOR INTERIOR REMODEL OF EXISTING OFFICE SPACE - ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS AND ONE AIR CONDITION AFFECTED AREA 1915 sqftb#17016-10000-34852	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37195	19041-20001-26023	6310 W SAN VICENTE BLVD 101	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM			PC Approved	07/09/2019 12:00:00 AM	ADDRESS	34.06084	-118.36757	SUPPLEMENTAL, PLAN CHECK ONLY, FOR TI T24 PLAN CHECK FOR TI REMODEL OF EXISTING HIGH RISE OFFICE. TOTAL SQUARE FOOTAGE = 3916 SFPERMIT FEE PAID UNDER AND PULLED UNDER PERMIT#19041-90000-26023	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37196	17041-10000-32136	18441 W DEVONSHIRE ST	91325	12	204B125   114	2731016007	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.25749	-118.53537	TITLE 24 PLAN CHECK FOR REPLACEMENT OF EXISTING (14)HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 18425 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37197	13041-10000-03526	7938 N SAUSALITO AVE	91304	3	189B101   346	2013013004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.21478	-118.61555	SINGLE STORY SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SIZE 8.64KW. TOTAL PANELS 36.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37198	17041-10000-25554	350 E 1ST ST Suite A&B	90012	14	129A215   347	5161017022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.04935	-118.23978	T-24 PC TENANT IMPROVEMENT TO (E) RESTAURANT.  SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. TOTAL SQ. FT. 2307.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37199	17041-10000-29837	340 N PACIFIC AVE	90731	15	018B197   596	7449011025	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.74584	-118.2877	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37200	18041-10000-08586	208 E 6TH ST #A-11	90014	14	127-5A211  94	5148022011	C2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.04434	-118.24886	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES REPLACING ELECTRICAL EQUIPMENT DUE TO FIRE DAMAGE. INSTALLING A NEW 600A 120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD AND NEW PANELBOARDS FOR B17, B18, B20A, B20B, B21, AND B22. TOTAL AFFECTED AREA IS 13670 SQ. FT. B#18016-10000-02466	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37201	14041-20000-04421	12500 W FOOTHILL BLVD	91331	7	216B161   489	2527022032	[Q]M1-1, [T][Q]P-1	North Valley	Arleta - Pacoima	Pacoima		1042.04	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	PIN	34.28571006	-118.40855723	PC FOR POWER AND ENERGY FOR BUILD OUT OF WAREHOUSE SPACE. TOTAL AREA ABOUT 55000 SQ FT. NEW PANELS AND REFEEDING EXISTING EQUIPMENT. NEW FEEDERS COUNTED AS NEW EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37202	19041-10001-17239	6216 N ORION AVE	91411	6	177B145   290	2242006012	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM			Reviewed by Supervisor	05/15/2019 12:00:00 AM	ADDRESS	34.18354	-118.46964	EXPEDITE PER APPLICANT REQUEST. ((PV1. NEW ROOFTOP SOLAR SYSTEM IN A SINGLE FAMILY DWELLING. CONSIST OF 45 MODULES (LONGI SOLAR 305), 45 OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTER (SE 11400H-US). SYSTEM SIZE IS 13.73 KWdc AND 11.4KWac))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37203	16041-10000-33020	724 S SPRING ST	90014	14	127-5A211 131	5144015041	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.04384	-118.25268	Plan check for power and energy change of use from office space to multi-tenant space in High-Rise Building. Total area: 4,981 sq ftNote: Building Permit # 16016-10000-16608	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37204	14041-10000-26209	8431 &-8435 W MELROSE PL	90069	5	141B173   416	5528001030	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	PIN	34.08387996	-118.37438106	Plan check for power and energy. This building is designed as a core and shell building only; separate building, electrical, and mechnical permits are required for all future residential unit and commercial tenant space build-outs.Connected load of 700 amps. Tenant improvement. Remodel 1st floor and add 2nd floor. Previously commercial property. BLDG#14014 - 10000 - 03101INVESTIGATION FEES DUE - work without permit for:ROOF STRUCTURE COMPLETELY REMOVED,FREESTANDING URM EXTERIOR WALLS NOT PROPERLY BRACED.WORK EXCEEDS SCOPE OF WORK DESCRIPTION ON PERMIT# 13016-10000-08382NOTE: INVESTIGATION FEES ARE A MINIMUM $400.00 OR DOUBLE THE PERMIT FEE WHICHEVER IS GREATER.  See LAMC Section 91.107.5.1. ORDER TO COMPLY ISSUED:  09/24/2014INSPECTOR:  JOHN JANSON PHONE:  213-202-9879(Created: JJANSON / 09-24-14)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37205	15041-20000-11259	444 S FLOWER ST Suite 2530-Suite 2580	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	Title-24 plan check only. Total area = 2,165 sq. ft. T.I. to existing office space in commercial highrise. New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37206	16041-10000-36086	20750 W MARILLA ST	91311	12	201B109   176	2748004044	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.24791	-118.58589	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING INDOOR HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 11900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37207	17041-20000-30042	6420 W WILSHIRE BLVD Suite 450	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Issued	08/23/2017 12:00:00 AM	ADDRESS	34.06365	-118.36922	"Plan check for energy only. TI to office suite 450 in high rise office building. New lighting - 331sqft.""COMPLY WITH DEPARTMENT ORDER effective date 08/14/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37208	16041-30000-41338	1819 S KELTON AVE	90025	5	129B153   712	4323007137	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.04845	-118.43869	Plan check for New Fire alarm System 4 story 26 units. Total Fire alarm devices: 131 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37209	13041-10000-35872	947 S TIVERTON AVE 8F,9F	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			12/24/2013 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.06246	-118.44303	pc for power and energy. assisted-living TI EXIST APT UNITS ON ENITRE 8TH AND 9TH FLOORS.4TH AND 5TH FLOOR PC # 13041-10000-356426TH AND 7TH FLOOR PC # 13041-10000-35862ADDITION OF GENERATORS AND PANELS  PC # 13041-10000-35626	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37210	14041-20000-18152	3617 S ROSEWOOD AVE	90066	11	111B149   264	4245011015	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.00305	-118.4463	4.5KW AC PV1 roof-mounted systen with (21) Enphase M215 microinverters and Trina Solar TSM-250P modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37211	11041-10000-06033	816 S FIGUEROA ST	90017	14	129A207   173	5144021035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	04/18/2011 12:00:00 AM	ADDRESS	34.0474	-118.26148	TI, T-24 ONLY OTC PLAN CHECK FOR EXISTING OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37212	17041-10000-05063	8350 N VAN NUYS BLVD	91402	6	192B149   185	2638022061	[Q]C2-1-CDO, [Q]R2P-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.22311	-118.44855	T-24, PC FOR ENERGY ONLY. REPLACE HID FIXTURES WITH NEW LEDs FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 20650 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37213	16041-30000-14576	10349 W SANTA MONICA BLVD	90025	5	132B157   446	4327017011	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.05868	-118.42285	Plan check for energy Title 24 only T.I. to existing car dealer. Total area: 3,615 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37214	17041-10001-41264	318 N WILTON PL	90004	4	138B193   322	5522033025	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Closed	09/03/2019 12:00:00 AM	ADDRESS	34.0768	-118.31338	"DELTA ""2"" Changes to approved plans for installing a 375W Central Inverter for the emergency lights in the commom areas instead of the Unit Equipment.<<<New 5 Unit , 4 story apartment building with 600A 240/120V 1ph-3w service.  Plan check for power and energy.    Building application number 16010-30000-05160>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37215	15041-10000-35763	6201 W HOLLYWOOD BLVD #118	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	ALTERATIONS INSIDE A SUSHI SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37216	15041-10000-16417	11818 W WILSHIRE BLVD UNIT 300-PHASE 5	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.0474	-118.46308	PHASE 5:REMODEL OF THE CURRENT TENANTS IN VIRTO FERTILIZATION (IVF) LAB AND ADJACENT AREA IN MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37217	15041-10000-08895	8416 W MULHOLLAND DR	90046	4	156B169   321	5565040044	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Issued	03/26/2015 12:00:00 AM	ADDRESS	34.12168	-118.38484	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.2KW INTERCONNECTED WITH MSP.((((APPLICANT HAS NO MEANS TO PAY WITH CREDIT CARD FOR ONLINE PERMITING)))))))))))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37218	13041-10000-09258	1501 N TOWER GROVE DR	90210	5	147B157   128	4356015001	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.09859	-118.4274	PV1 2 STORY SINGLE FAMILY DWELLING. PLAN CHECK NEW 39.24 KW GROUND MOUNTED PHOTOVOLTAIC SYSTEM. 120 MODULES, 3 COMBINER BOX, 3 INVERTERS. [INVERTER: SUNPOWER SPR-11401F-1 UNI] [MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37219	10041-20000-13758	17107 W VENTURA BLVD	91316	5	168B133    17	2258012028	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Closed	10/01/2010 12:00:00 AM	ADDRESS	34.16046	-118.50575	OUTDOOR LIGHTING. TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37220	18041-20002-15062	11301 N RIVERWOOD TER	91040	7	210B189    35	2551007004	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District, Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.27426	-118.31856	05-22-2018, Changes to an approved set of plan, Changes include reduce main panel from 225A to 200A panel and reduce main breaker from 200A to 175A main breaker.Plan Check onlyFees $0.00 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37221	18041-10000-09724	1315 W FLORENCE AVE	90044	8	102B197  1154	6014033032	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Public Safety Only			03/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	33.97475	-118.29859	FIRE WARNING SYSTEM FOR 20-UNITS 3-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37222	13041-20001-23737	11112 W WELBY WAY	91606	2	180B173    31	2319014012	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.1936	-118.37305	((EXPEDITE FEES))PV1 TRANSFOMERLESS SYSTEM. 32 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37223	18041-10000-12164	2512 N MICHELTORENA ST	90039	4	150A205   193	5432015020	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.1054	-118.2698	NEW 4KW PV SYSTEM ON A SINGLE FAMILY HOME W/12 AC MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37224	19041-20000-21423	8737 N MATILIJA AVE	91402	6	195B153   978	2637003025	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.22863	-118.43699	Plan check for a PV1 roof-mounted PV system. System size is 5.53 kWdc/5.36 kWac-CEc and consists of (19) modules, (19) micro-inverters, (2) load centers, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37225	15041-10000-26862	410 N LA CIENEGA BLVD	90048	5	138B173    27	5514001011	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.07843	-118.37638	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW OUTDOORS LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 177.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37226	16041-30000-13641	444 S FLOWER ST STE#1650	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	Title 24 plan check only.  Total area = 2,820 sq. ft.      T.I. to existing commercial highrise office space.  Subpanels to remain existing.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37227	13041-10004-01477	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM			PC Info Complete	02/24/2014 12:00:00 AM	ADDRESS	34.03393	-118.22985	Fees under inspection.CHANGES TO APPROVED: AS-BUILT SET. reduced load and changed lighting. original description:First time tenant for a restaurant space.  Power and energy.PLACE OF ASSEMBLY. OCCUPANT LOAD: 220+	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37228	12041-10000-26978	334 S 4TH AVE	90291	11	111B141   592	4240008027	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	12/20/2012 12:00:00 AM	ADDRESS	33.99677	-118.47415	PV1 ROOF MOUNTED. M215 ENPHASE MICROINVERTER. STANDARD MICROINVERTER PLAN CHECK OVER COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37229	17041-10001-04356	7270 W WARING AVE	90046	5	141B181   293	5525012026	R1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.0852	-118.34819	03/22/17Changes to an appoved set of plans(PV1). Changes include relocating solar modules on the roof-layout, and revising single line to reflect what is the field. Solar system is interconnecting to a 225A Main service panel instead of a 100A Main service panel. Note: Permit is paid under PCIS#17041-10000-04356	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37230	17041-20000-19151	700 S FLOWER ST 10th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for energy only. TI to existing restrooms on 10th floor of high rise building. New lighting (incl. emergency) - 574sqft. New exit signs in corridor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37231	10041-20000-22552	545 S FIGUEROA ST 5th fl-phase 4	90071	9	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	11/23/2011 12:00:00 AM	ADDRESS	34.0514	-118.2582	5th floor energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37232	18041-10000-16444	1578 W COLORADO BLVD	90041	14	162A227   112	5689018023	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.1393	-118.20084	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37233	16041-10001-44822	1680 N VINE ST UNIT 4	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Issued	12/28/2017 12:00:00 AM	ADDRESS	34.10133	-118.32648	EPC FOR NEW RESTAURANT. ADDING 5 NEW PANELS, LCP AND DIMMER PANELS, CIRCUITS, LOADS & T-24 IN A HI-RISE BUILDING. PER APPROVED VARIANCE FORM BY MR. GILBERT, UNIT EQUIPMENT ARE PROVIDED FOR EMERGENCY LIGHTS.  NEW DESIGN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37234	19041-10001-38388	1745 E 7TH ST 1ST FLR	90021	14	124-5A215  58	5164022012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			PC Info Complete	11/15/2019 12:00:00 AM	ADDRESS	34.0349	-118.23475	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING, CONTROLS, AND CIRCUITS ON THE 1ST FLOOR. TOTAL AFFECTED AREA IS 5305 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37235	10041-20000-20206	10210-10216 N CANOGA AVE Building A	91311	12	204B105   430	2747011039	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM	01/24/2011 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.25581	-118.59713	PLAN CHECK FOR NEW INSTALLTION OF 10.5KW AND 5.5KW ROOF MOUNTED PHOTOVOLTAIC SYSTEMS FOR BUILDING A WITH 2 EXISTING SERVICES SUPPYING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37236	16041-10000-38798	24728 W WOODED VISTA	91307	12	177B085    30	2032004019	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.1854	-118.66444	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.55KWdc / 7.20KWac(30)MODULES-SOLARWORLD SW 285(30)ENPHASE M250-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37237	19041-20000-50960	8768 N CORBIN AVE	91324	12	195B117   156	2783025095	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.22965	-118.5621	T24 PLAN CHECK, ENERGY ONLY, TOTAL SQUARE FOOTAGE = 4795 SFPERMIT PARTIALLY PAID UNDER 19041-20000-48488	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37238	11041-10000-10484	2723 W 8TH ST #201,204	90005	10	132A201    11	5077020802	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.02, 2122.04	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM	06/08/2011 12:00:00 AM		Permit Finaled	06/27/2011 12:00:00 AM	ADDRESS	34.05787	-118.28484	First time tenant for a Billiard place. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37239	19041-20000-41065	11881 W TERRA VISTA WAY #119	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37240	16041-20000-05868	10000 W VALLEY SPRING LANE	91602	4	165B181   499	2424037016	A1-1XL-RIO, R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.14541	-118.34832	Plan check Title 24 only T.I. in existing space  commercial kitchen (Private Golf Club). Total newly connected load less than 400A. Total area:  4,540 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37241	15041-10002-35073	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 35	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37242	19041-20000-44606	1319 S ST ANDREWS PL	90019	10	129B193  1396	5073006004	R3-1-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.04	Electrical	Electrical	Apartment			10/31/2019 12:00:00 AM			Reviewed by Supervisor	11/20/2019 12:00:00 AM	ADDRESS	34.04664	-118.31184	Power and lighting for remodel of (E) building.  Existing service and distribution, new unit subpanels and wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37243	18041-10001-25818	320 N MADISON AVE	90004	13	138B197   191	5501002032	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.07708	-118.28902	Change to an approved set by relocating equipment per fire department request.(((NEW FIRE ALARM SYSTEM IN THE BUILDING WITH 460 DEVICES.BLDG PERMIT: 17010-10000-01411)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37244	14041-20000-05120	5941 N VARIEL AVE BLDG C-4	91367	3	177B105    95	2149002024	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.17808	-118.59256	T24 FOR EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37245	16041-10005-42610	695 S SANTA FE AVE	90021	14	124-5A2171363	5164019026	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	09/04/2020 12:00:00 AM	ADDRESS	34.03508	-118.23039	CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON CLOUDED AREAS DELTA W. CHANGES INCLUDE FEEDER CHANGES AND ADDITION OF DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37246	15041-10003-00994	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***		Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			Reviewed by Supervisor	08/20/2015 12:00:00 AM	ADDRESS	34.1504	-118.32742	installation of an isolation xfmr 1500KVA 12.47KV - 12.47/7.2KV IN ORDER TO PROVIDE PROPER GROUNDING TO TEMPORARY INSTALLATION OUTLINED BELOW((((((((MODIFYING TEMPORARY INSTALLATION; OVER CURRENT RELAYS ON THE SEC OF XFMR AND ADD LOAD INTERRUPTER SWITCH WITH FUSES ON THE PRI SIDE;HAVING THE MV XFMR MOUNTED ON A SKID AND THE INSTALLATION HAVING K-RAILS AROUND THE INSTALLATION INSTEAD OF WIRE FENCE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37247	14041-10000-32883	835 W JEFFERSON BLVD	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.02411	-118.28451	Full plan check for USC doomitory (Conditioned floor area: 101,341 sq ft) and (unconditioned floor area: 1,881) with 5 stories and 66 units(6 common units). The address need to be change to correct address before pulling the permit. variance for fire alarm submitted.  second variance is for tieing in smoke detector tor main fire alarm system by others.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37248	16041-20000-26690	9512 N TEXHOMA AVE	91325	12	201B129   434	2755009031	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.24378	-118.51652	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 5kW ungrounded system.(17) 300W pv modules. Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37249	15041-20000-07895	6250 N TOPANGA CANYON BLVD BLDG F-SUITE 1510	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	TI to a new commercial building (juice bar). First time tenant. Plan check for power and energy. Total Sqft. 844	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37250	19041-20000-42374	11946 MIRABEL WAY	91326	12	216B109   179	2701081028	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	PIN	34.29018864	-118.58188126	Plan check for PV roof mounted system, PV system size: 5.25KW with 15 PV AC Modules, new sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37251	18041-10000-27231	2330 W BEVERLY BLVD	90057	13	136-5A203 219	5154014025	C2-1	Central	Westlake	Westlake North	Yes	2085.02	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.06798	-118.27383	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37252	06041-10004-23699	330 S CENTRE ST HQ Bldg	90731	15	018B201   821	7455019919	C2-2	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM			PC Approved	11/04/2010 12:00:00 AM	ADDRESS	33.74055	-118.28332	REVISIONS TO PERMITTED SET OF PLANS- NEW CIRCUITS AND REVISED PANEL/SERVICE CALCULATIONS.Revision to approved set of plan. Just panel P1HA is serise rated with upstream EDB BRKR. all others are fully rated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37253	17041-20000-37959	3410 W 3RD ST	90020	13	135B197   183	5501024028	(Q)P-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM			PC Approved	10/20/2017 12:00:00 AM	ADDRESS	34.06884	-118.29027	Plan check for energy only. TI to (E) grocery store (Ralph's). Install new lighting. Retrofit existing lighting to LED. T24 area - 39,373sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37254	14041-20000-14481	4913 S CENTRAL AVE	90011	9	111A209   155	5108018004	C2-1VL	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	33.99885	-118.25666	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. SUITE 4913, 4915, AND 4917	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37255	18041-20000-08547	14943 W VOSE ST	91405	6	183B145   241	2220006050	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.19857	-118.45883	PV1.  Install 6.195 kW roof mounted grid tied PV system.  (21) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37256	14041-20000-14550	6124 N CAPISTRANO AVE	91367	3	177B101    92	2039029025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.18169	-118.61709	pv1 single family. using central tranformed inverter. using standard plan. 4 strings((low permit fee due to senate bill 1222 from 2012))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37257	13041-10000-24270	2301 W BELLEVUE AVE FLOORS 8,-9 & 15	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.07417	-118.26931	POWER AND ENERGY PLAN CHECK. PER APPLICANTS INFO, FIRST TIME TENANT TO FLOORS 8, 9 AND 15 OF HIGH RISE. 25101 SQFT. EXISTING PANELS WITH NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37258	11041-10000-18383	1241 S SOTO ST	90023	14	121-5A221 147	5170017030	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.02743	-118.21975	NEW RESTROOMS ON THE 1ST AND 2ND FLOORSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37259	16041-10000-01265	11761 W ROSCOE BLVD	91352	6	192B169   438	2633031902	[Q]PF-1XL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1218.02	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Issued	05/05/2016 12:00:00 AM	ADDRESS	34.22177	-118.38982	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 110KW INTERCONNECTED WITH MSP.(410) MODULES(4) ABB INVERTERS 27.6KWFEE PERMIT $0.00 DUE STATE SENATE BILL NO. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37260	18041-10001-08526	9217 S AIRPORT BLVD	90045	11	093B169    89	4124009920	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM			PC Approved	10/19/2018 12:00:00 AM	ADDRESS	33.95197	-118.38615	Plan check for Delta-1 only: Changes to approved set, revise lighting type and wattage. Lighting floor plan, T24 calculation, and photometric are revised accordingly.  This is plan check only, permit is covered under master plan.((SERVICE AND POWER AND LIGHTING FOR NEW AVIS PARKING LOT))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37261	10041-10001-16421	2049 S CENTURY PARK EAST 25th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM			PC Approved	11/29/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	CHANGES TO APPROVED PLANS.    <<<<<<<<<<TI in the elevator lobby of the 25th floor. Plan Check is for T-24 energy calcs and emergency light.>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37262	16041-10000-09483	15359 W OXNARD ST	91411	6	177B145   440	2242001020	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.17957	-118.46823	Install two (New) horizontal tank for generic additive to the (E) Chevron Refinary facility. (reviewed by A.F.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37263	18041-20000-16621	4835 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	05/24/2021 12:00:00 AM	ADDRESS	34.0467	-118.34147	Service, power, and lighting for change of use from bank to restaurant.  1200A 208Y/120V 3ph-4w service and associated distribution.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37264	13041-10000-03088	3601 S WATT WAY	90089	8	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Expired	03/03/2015 12:00:00 AM	ADDRESS	34.02113	-118.28752	PLAN CHECK FOR REPLACE EXISTING FACP ON BASEMENT LEVEL, ANNUNCIATOR ON FIRST FLOOR AND REPLACE DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37265	16041-10000-31860	21900 W BURBANK BLVD # 210	91367	3	174B105    46	2146007120	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.17189	-118.60404	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1124 SQ. FT. B#16016-10000-16274NOTE: PERMIT IS PAID UNDER PCIS#16041-90000-29642	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37266	14041-20000-34035	1750 S SAWTELLE BLVD 1-15	90025	11	126B149   206	4261019019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.04429	-118.44625	Plan check for fire alarm system for commercial	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37267	17041-10000-21778	13287 N RALSTON AVE	91342	7	225B141   172	2501002027	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.31289	-118.47324	TItle 24 plan check.  Replace existing fixtures with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37268	16041-10001-11496	5814 N VANALDEN AVE	91356	3	174B121    84	2156009022	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.17638	-118.55014	CHANGE TO PERMIT. ADDITION OF 4 MODULES. NEW COUNT IS NOW 15 MODULES. TOTAL SYSTEM SIZE 3.8 KW AC. USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37269	18041-10000-40683	10107 N SOPHIA AVE	91343	12	204B137   713	2678005018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.25419	-118.48828	Plan check for a PV1 6.24KW AC  roofmounted system with (26) modules and Enphase microinverter interconnecting through the service panel. Portion of the fee is paid under application number: 18041-90000-35063.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37270	17041-20000-00093	7900 N BALBOA BLVD	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Issued	03/08/2017 12:00:00 AM	ADDRESS	34.21347	-118.50092	Plan check for power.  Aviation refueling station in Van Nuys airport. Provide power to aviation self-serve gas tank and pumping system (hazardous classification).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37271	14041-20001-28101	9335 N URBANA AVE	91331	6	198B153   549	2642021042	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM			PC Approved	05/12/2015 12:00:00 AM	ADDRESS	34.23965	-118.43292	Plan check for PV only per inspector request. (((((PV1.  Install 5.5 kW roof-mounted, utility-interactive PV system.  Microinverters.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37272	14041-20000-17580	11842 S TEALE ST	90230	11	105B165   392	4220014019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Info Complete	08/26/2015 12:00:00 AM	ADDRESS	33.98474	-118.40178	New 3-story commercial office building.  Power and energy for core and shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37273	12041-10004-29911	"12722 W MILLENNIUM BLDG ""B"""	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	33.9761	-118.41564	SUPPLEMENTAL TO APPROVED SET OF PLANS.  REVISIONS TO T24 LIGHTING AND INSTALLING 30 KVA TRANSFORMER.  DELTA D AND DELTA 37 REVISIONS ONLY.  AFFECTED SHEETS: E2.B.00E2.B.02E2.B.03E2.B.04E4.B.01E8.B.01	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37274	17041-20000-04641	14216 W GILMORE ST unit 2	91401	6	180B153   960	2237020009	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.18753	-118.4429	pv2install roof mounted pv system sized 3.75kw interconnected with msp.  This is system 2 of 5.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37275	18041-20001-33662	19552 W LEMARSH ST	91324	12	204B117   320	2726015001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM			PC Approved	09/24/2018 12:00:00 AM	ADDRESS	34.25531	-118.55958	expeditepv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37276	12041-10000-06037	5857 N FULTON AVE	91401	2	174B157    21	2343025008	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.17737	-118.42269	PV system SFD, 10.2 KW, standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37277	19041-20002-16303	2576 N BASIL LANE	90077	5	154-5A151 189	4379005***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.1185	-118.44782	Supplemental plan check only for changes to approved set. addition of a AC disconnect. minor change to single line, roof plan, and signage page. clouded changes only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37278	13041-20000-22790	12780 N SAN FERNANDO ROAD mezzanine	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.30237	-118.46212	Tenant improvement within existing manufacturing/office sapce.  Load is less than 400 amps.  Plan Check only for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37279	17041-10000-13435	10250 W SANTA MONICA BLVD # 1945	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan chk, First Tenant-Hugo Boss Ste. 1945 at Westfield Century City	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37280	13041-20000-09830	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM			PC Approved	04/16/2013 12:00:00 AM	ADDRESS	33.98645	-118.44148	ENERGY PLAN CHECK ROOF OF AN EXISTING GARAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37281	15041-10000-28377	400 S HOPE ST 101-102	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			PC Info Complete	11/05/2015 12:00:00 AM	ADDRESS	34.05199	-118.25366	PC FOR ENERGY. REPLACEMENT OF EXISTING FLORESCENT FIXTURES WITH NEW LED LIGHT FIXTURES IN 4 LEVELS PARKING OF A COMMERCIAL BUILDING. TOTAL AREA 33206 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37282	17041-20000-23033	12476 N WOODLEY AVE	91344	12	219B137    49	2605005004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.29779	-118.49503	Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (18) micro-inverters, (36) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37283	16041-10003-20288	5820 S 3RD AVE	90043	8	108B189  1483	4005022006	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	33.98851	-118.32045	changes to approved set	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37284	19041-10000-08250	8825 N KESTER AVE	91402	6	195B149   277	2653006***	OS-1XL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.23088	-118.45762	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37285	11041-20000-24069	11728 W WILSHIRE BLVD BLDG 'B'	90025	11	129B145   644	4263009030	R4-1, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.04885	-118.4613	INTERIOR TENANT IMPROVEMENT IN (E) LOBBY OF BUILDING 'B' NON-STRUCTURAL. Energy, emergencyFire/ Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37286	19041-20000-02282	3720 N LITCHFIELD LANE	91356	3	162B117   401	2177043011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.13655	-118.55193	Plan check for PV roof mounted system, sytem size: 21.17KW DC, 19.00KW AC with 73 PV Modules and 2 inverters(7.6KW and 11.4KW).$0 permit fee due to State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37287	16041-20001-03513	4114 W SEA VIEW LANE	90065	1	151-5A221 308	5471001047	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	ADDRESS	34.10825	-118.21542	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. System size: 6kW+6kW=12kW. Ungrounded system. Each module has a 400W power optimizer. (46) 345W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37288	14041-10000-28809	3844 N WINFORD DR	91356	3	162B121    67	2177041003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.14043	-118.54927	PV1, INSTALL 13.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(40) MODULES: SPR-X21-345 (2) INVERTERS: FRONIUOS IG PLUS A 6.0-240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37289	12041-20000-23575	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	34.05494	-118.23752	Title 24 Energy only 2415 sq ft.  Union Station.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37290	12041-10000-04242	11806 W GLAMIS ST	91342	7	210B169   967	2530029014	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.06	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.27639	-118.38936	(21) PV solar modules on SFD roof. Service upgrade to 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37291	14041-20000-01338	7732 N RHEA AVE	91335	3	189B121   614	2103019011	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.21128	-118.54136	PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37292	10041-20000-15695	333 S HOPE ST 54th Floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	09/28/2010 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check T-24 Energy for conference TI on the 54th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37293	17041-20000-32785	7721 N BABCOCK AVE	91605	2	189B161  1063	2307002029	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.21099	-118.40671	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (26) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37294	10041-20001-05319	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM			PC Approved	01/05/2012 12:00:00 AM	ADDRESS	34.10137	-118.34182	Modification of the equipment grounding conductor in the MDA feeder, change for 700 to bare 750 MCM copper.  The 3-1/2  conduit is indicated as EMT and wire insulation type THHN/THWN conduit fill is less than 40%.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37295	15041-20001-19829	20800 W DEARBORN ST	91311	12	198B109   153	2748037018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.23712	-118.58631	07-29-15 Change to approved set of plans. Changes include relocation of 75KVA transformer and (2)400A panel.[[[[add 4 panels and two transformers TI]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37296	18041-20000-23204	11328 N ORO VISTA AVE	91040	7	210B189    24	2551007006	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.27463	-118.31687	PV1.  Install 15.3 kW DC roof mounted grid tied PV system.  (51) modules with 10.0 and 5.0 kW rated string inverters.$9.04 permit fee per State Senate Bill SB 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37297	15041-20000-35853	6100 W CENTER DR SUITE 750	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM			PC Info Complete	10/26/2015 12:00:00 AM	ADDRESS	33.97733	-118.3922	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS ON SUITE 750.  TOTAL AREA IS 7210 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37298	10041-20000-16038	9667 N OWENSMOUTH AVE	91311	12	201B105   186	2746016019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	08/24/2010 12:00:00 AM	ADDRESS	34.24591	-118.60229	Plan check for new equipment installed to existing electrical system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37299	08041-10002-14285	606 N FIGUEROA ST	90012	1	135A213   324	5407004030	C2-2D	Central	Central City North	Historic Cultural	YES	2071.01	Electrical	Electrical	Apartment			01/20/2010 12:00:00 AM			PC Info Complete	04/28/2010 12:00:00 AM	ADDRESS	34.06276	-118.24601	Plans were lost, new submittal for 08041-10001-14285.  Changes to approved plans:  The service size decreased, panels, circuits, lights and equipment were added, and seom equipment was relocated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37300	17041-10000-46445	1100 S GLENDON AVE #1850	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	PC FOR OFFICE TI FOR TITLE 24 ENERGY  ONLY IN A HIGHRISE. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 2788 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37301	13041-10001-30392	2250 N TRACY TER	90027	4	148-5A205 160	5433017006	[Q]C1-1XL	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	34.10195	-118.27352	][][]EXPEDITED PER APPLICANT REQUEST ][][][PV1. ROOF MOUNTED SOLAR ARRAY. MICROINVERTER NON STANDARD PLAN, TO BE INTERCONNECTED TO 400A SERVICE PANEL W/ (2) 100A MAIN BREAKERS. SYSTEM SIZE IS WITH (21) SHARP 240W MODULES, (21) ENPHASE M215 MICROINVERTERS. NEW 100A SUBPANEL WILL BE ADDED. SYSTEM SIZE IS 4.515 KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37302	18041-30001-39653	1443 W JEFFERSON BLVD	90007	8	120B197   622	5040002002	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.02563	-118.29872	PLAN CHECK FOR T-24, SCOPE OF WORK INCLUDES NEW LIGHTING TO AN ART STUDIO. TOTAL SQ. FT. 2898.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37303	18041-20002-35525	4955 N VAN NUYS BLVD ste 111	91403	4	169-5A151  13	2263026046	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.16078	-118.4489	09-12-2019 Changes to an approved set of plan, Changes include update ATS to 200A and update fault current calculation at Generator. All Changes has been clouded as Delta 4 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37304	19041-10000-00243	435 S LOS ANGELES ST	90013	14	129A213   271	5148009001	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/26/2021 12:00:00 AM	ADDRESS	34.04667	-118.24723	T-24, PC FOR ENERGY ONLY. TI FOR A RESTAURANT SPACE. SCOPE INCLUDES NEW LIGHTINGS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1840 SQ. FT. B#18016-10000-30248	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37305	19041-10000-16705	1848 N REDCLIFF ST	90026	13	145-5A205 135	5431028003	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.09382	-118.27041	PV1 roof mounted, system size is 3.8 KWac/4.65KWdc. 15 modules with optimizers ( P320), and one central inverter (SE3800H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37306	14041-10000-00528	431 S BURNSIDE AVE	90036	4	135B181   326	5509005009	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Expired	03/01/2016 12:00:00 AM	ADDRESS	34.06636	-118.35098	INSTALL  A NEW FIRE ALARM SYSTEM FOR  A HIGH RISE BUILDING WITH 14 STORIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37307	12041-10000-08820	10628 W VENTURA BLVD	91604	2	162B177   386	2378001007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.13768	-118.3641	REMODELING EXISTING RESTAURANT-NEW CIRCUITS AND LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37308	16041-10000-42829	2020 N CUMMINGS LANE	90027	4	151-5A195 197	5589009032	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.10784	-118.30112	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.2KWac.(35)AC MODULES-SUNPOWER SPR-X21-335-BLK-C	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37309	16041-10000-28387	10960 W WILSHIRE BLVD SUITE 1960	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check Title 24 only in existing high-rise space T.I. Total area: 1903 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37310	17041-10000-42143	6255 W SUNSET BLVD STE 680	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	PC FOR TI IN (E) OFFICE SUITE 680 IN A HIGH RISE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1975 SQ. FTB# 17016-10000-32577	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37311	16041-20002-40686	6040 N CALVIN AVE	91356	3	177B117   584	2153035013	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2017 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.1803	-118.55544	(1/30/2017)changes to an approved set of plans.  changes include the point of connection. this is plan check only.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 400A split bus panel.20.16kW ungrounded system. (56) 360W ac modules. NOTE: Fees are $0 due to Senate Bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37312	11041-10000-07237	200 W MANCHESTER AVE	90293	11	096B149   749	4116028014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	PIN	33.95492043	-118.44692298	NEW ADDITION TO AN EXISTING BUILDING.  ADDITIONAL SQFT IS 5,523 SQFT.  NEW PANEL AND ADDITIONAL BRANCH CIRCUITS.  FULL PLAN CHECK.  Permit is pulled under 11041-10001-07237	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37313	13041-10000-35618	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	33.98173	-118.4029	PLAN CHECK FOR POWER AND ENERGY. CORE AND SHELL. NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY 29775 SF WITH NEW SURFACE PARKING LOT2 of 2. BUILDING 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37314	12041-10002-27463	500 W WORLD WAY T5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	Changes to approved set of fire alarm plans. delta 6 changes only. replacing 6 control relays and removing 6 smoke detectors. changes are clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37315	13041-20000-17532	12121 W WILSHIRE BLVD	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			Corrections Issued	07/02/2013 12:00:00 AM	PIN	34.04391963	-118.46825257	T24 FOR EXISTING HIGHRISE OFFICE SPACE SUITE 1000. TOTAL SQRFT 4,459. PERMIT HAS BEEN PULLED UNDER APPLICATION#: 10341-30000-16714	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37316	14041-10001-17249	1550 N EL CENTRO AVE	90028	13	148-5A189 303	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.09961	-118.32359	CHANGES TO APPROVED SET OF PLANS under delta 7. Modified sheets are 0.00, 5.00, 6.01, 6.02, 6.03, 6.04 ,6.06 ,6.07, 7.04. . Plan check for power only. CHANGING DISTRIBUTION BOARDS OF 20 FLOORS FROM  7 800A TO 18 400A and addition of generator panel and transformer.<<<  fire alarm variance has been filed on 2/26/2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37317	14041-10000-16568	3002 S 10TH AVE	90018	10	120B185   380	5051035008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.02747	-118.32811	PV1 1.728KWAC. 240V. microinverter. STD. 1story. Roofmount. [(8) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(8)modules: {solarworld SunModule SW-270 mono}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37318	18041-20001-28554	11254 W KAMLOOPS ST	91342	7	213B173   157	2530037003	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2018 12:00:00 AM			PC Approved	10/12/2018 12:00:00 AM	ADDRESS	34.28076	-118.37668	Expedited plan check fee.PV1.  Install 6.96 kW roof mounted grid tied PV system and energy storage system.  (24) modules with 7.6 kW rated string inverter and 9.8 kWh rated battery backup.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37319	10041-10000-06506	4744 N LANKERSHIM BLVD	91602	4	168B173   600	2421015025	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM	03/15/2011 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	34.15684	-118.36954	NEW TENANT IMPROVEMENT TO A  CVS PHARMACY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37320	11041-10000-25078	5250 N LANKERSHIM BLVD 5TH  FL	91601	4	171B173  1421	2350018090	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.16668	-118.37545	Plan check for compliance with lighting reqmts. of T-24 including egress ltg. and exit signs @ 5th floor elevator lobby and  common corridor (ONLY). Fire alarm devices are exist. to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37321	19041-20000-47183	4046 N WOODMAN CYN	91423	4	162B157   182	2373015008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.14311	-118.43009	PV1. INSTALL 9.72 KW DC PV SYSTEM WITH (27) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37322	15041-10000-01050	12550 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/13/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	33.97815	-118.41197	Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37323	13041-10000-30030	6028 S EILEEN AVE	90043	8	105B181   741	4004023007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Expired	11/30/2015 12:00:00 AM	ADDRESS	33.98453	-118.34272	PV1.  Install 4 kW DC roof-mounted photovoltaic system, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US., power optimizer, and  16 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37324	12041-10000-02878	1700 E CESAR E CHAVEZ AVE # 2400	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.05093	-118.21753	Tenant improvement in an  existing eye clinic-new panelboard and circuitsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37325	15041-10000-05529	10700 S PERSHING DR	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	33.93748	-118.43218	TEMPORARY INSTALLATION 0F OVERHEAD MESSENGER CABLE FROM  EXISTING SWITCHBOARD TO A BATCH PLANT-SEE 14041-10000-03317 FOR SIMILAR INSTALLATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37326	12041-20000-16564	325 W ADAMS BLVD temp2	90007	9	123A205   197	5126018035	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.02712	-118.27319	NEW 800 AMP TEMPORARY POWER  ii  FOR A NEW 6 STORY MIXED USE BUILDING.  other temp power permits  (EPC # 10041-10000-25737 & 10041-10000-25736)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37327	17041-10003-07409	20221 S HAMILTON AVE	90502	15	054B197    33	7351033022	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	33.84695	-118.28626	05/29/2018Changes to an approved set of plans, Changes include the revision of lighting lay out and addition of a communication room. ________________________________________Changes to an approved set of plans. Changes include identifying manufacturer for lighting controls. Floor plans to reflect as built. Note: Permit is paid under PCIS#17041-10000-07409	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37328	16041-20000-43904	9653 N AMESTOY AVE	91325	12	201B133   455	2692017009	RA-1-H	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.24627	-118.50694	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (44) modules, (44) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37329	10041-20001-08227	15823 W MONTE ST #103	91342	7	225B141  1524	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM			PC Approved	05/12/2010 12:00:00 AM	ADDRESS	34.31094	-118.47588	Plan check only power for first time tenant for unit #103. Existing permit and plan check T-24 Energy under plan check #10041-10000-08227	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37330	14041-20000-20822	9559 N HANNA AVE	91311	12	201B101   845	2727023009	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.24431	-118.60786	Standard Plan: 4.3KW PV1 roof-mounted system including: (20) Solar World SW-275, and (2) Enphase M215 Microinverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37331	14041-20000-26497	1515 W 190TH ST Suite 101	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	33.85852	-118.30531	(E) office TI remodel in low-rise commercial office building.  Plan check for 2013 Title 24 Part 6 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37332	11041-20000-17780	15335 W MORRISON ST	91403	2	171A145   182	2263039003	(Q)CR-1, (Q)P-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.16066	-118.46749	Plan check roof mounted 48.2KW Photovoltaic system. Permit for PV System and includes installing two new 225A subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37333	17041-10001-35953	1082 S GLENDON AVE	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.06097	-118.44424	PLAN CHECH FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE CHANGING CONTROLS SYSTEM TO NLIGHT SYSTEM. CHANGES NOTED UNDER DELTA 3. NO CHANGES TO LUMINAIRES NO NEW LOAD WAS ADDED PC FOR POWER AND ENERGY FOR TENANT IMPROVEMENT FOR MEDICAL OFFICE. NO CHANGE IN EXISTING USE OR OCCUPANCY.  OFFICE IN A HIGH RISE BUILDING. SCOPE INCLUDES NEW PANEL, EQUIPMENT AND CIRCUITS. TOTAL AFFECTED AREA 1000 SQ.FT. B# 17016-10000-27052	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37334	19041-10001-22989	19627 W LASSEN ST	91324	12	201B117    79	2726012023	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.25014	-118.56102	Plan check only. CHANGES TO AN APPROVED SET. REMOVING ONE MODULE WITH 1 MICRO-INVERTER. SERVICE AND PANEL UPGRADE IS NO LONGER A PART OF THIS SCOPE.  Original scope: NEW ROOFTOP SOLAR SYSTEM CONSIST OF 17 MODULES (Q-CELL 285) , 17 MICRO-INVERTERS (IQ7-60 240).  SYSTEM SIZE IS 4.85KWdc and 4.08KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37335	10041-10001-08576	11707 W SAN VICENTE BLVD	90049	11	132B145   531	4401018017	C1.5-1VL	West Los Angeles				2641.03	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM			PC Approved	09/29/2010 12:00:00 AM	ADDRESS	34.05377	-118.46609	REVISED PLANS FOR THE REMODELING THE INTERIOR OF AN EXISTING  STARBUCKS COFFEE SHOP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37336	11041-10001-23664	808 N NORTH SPRING ST	90012	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM			PC Info Complete	10/15/2012 12:00:00 AM	ADDRESS	34.06198	-118.23674	PLAN CHECK REVISION TO APPROVED PLANS. CHANGES TO  SHOW AS - BUILT CONDITIONS AND SEPERATE EMERGENCY LOADS FROM LEGALLY REQUIRED/OPTIONAL LOAD. ADDITIONAL PERMIT FOR EMERGENCY ATS, EMERGENCY DISTRIBUTION BOARD, WINDOW WASHING EQUIPMENT, AND LARGER SIZE DOMESTIC PUMP EQUIPMENT, AND 75KVA TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37337	16041-20001-21583	3627 N CODY ROAD	91403	4	159B145    65	2278024004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.1361	-118.46394	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM . MICROINVERTERS. SYSTEM SIZE: 17.05 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37338	12041-10000-21861	2619 E 8TH ST	90023	14	121-5A221  25	5170006007	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.0284	-118.2198	Plan check for upgrade to 600A service. Existing commercial warehouse building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37339	17041-20001-04249	1697 S PACIFIC AVE ROOFTOP	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	ADDRESS	33.98722	-118.47211	11/6/2017 Changes to an approved set of plans.  changes noted delta 1.  changes include lighting fixture types and revised energy calculations.  this is plan check only.  *****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NEW ROOFTOP KITCHEN. PHASE 1. NOT A HIGHRISE PER APPLICANT. NEWLY CONNECTED LOAD < 400 AMPS.  332 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37340	16041-20000-34945	618 1/2 E 1ST ST 2nd flr	90012	14	129A215    96	5163002020	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM			Reviewed by Supervisor	10/13/2016 12:00:00 AM	ADDRESS	34.04855	-118.23637	service upgrade  600 amps to an existing two stoty commercial building.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37341	19041-10000-15338	433 S SPRING ST 10TH FL	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM			PC Approved	04/25/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	TI IN EXISTING CONFERENCE AND PRIVATE OFFICEPLAN CHKIS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37342	17041-20000-46289	17835 W MAYERLING ST	91344	12	216B129   320	2601065022	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.2862	-118.52149	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. (E) solar system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37343	11041-10000-18876	515 S FLOWER ST # 700	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM	09/29/2011 12:00:00 AM		Permit Finaled	01/07/2013 12:00:00 AM	ADDRESS	34.05134	-118.25661	INTERIOR NON STRUCTURAL OFFICE  T.I. ON 7TH FLOOR TENANT SPACE.  (N) PARTITIONS, DOORS, CEILING, FINISHES & MILLWORK.  20,105 S.F.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37344	17041-20001-30126	5422 N KATHERINE AVE	91401	4	171B153    32	2245024020	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.16937	-118.44311	EXPEDITE PER APPLICANT REQUEST.lan check for solar pv system with AC coupled battery backup system.(1) 10kW ungrounded inverter. (36) 325W pv modules. (36) 400W power optimizers.(2) 5kW Tesla Powerwall 2's.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37345	15041-10000-31189	2800 E OLYMPIC BLVD	90023	14	120A221    89	5170026018	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.02314	-118.21766	TI to (E) commercial tenant space for AutoZone.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37346	17041-10000-37895	634 S MATEO ST	90021	14	124-5A217  44	5164013037	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.03694	-118.23237	Plan check for power and energy T.I. existing warehouse change of use to office, production, penny arcade and restaurant for one tenant. Total area: 58,675 sq ft. Service size: 277/480V, 1600AInstalling distribution boards, tranformers, panels, cirucits and equipment. This location is in Methane zone.B#17016-10000-30380	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37347	11041-20004-20870	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Info Complete	05/28/2015 12:00:00 AM	ADDRESS	34.02174	-118.39786	"(20004) Changes made to approved set.  Addition of one new panel with associated loads.  Addition of outdoor lighting (and new Title-24 sheets).  *****     (20001)  CHANGES MADE TO APPROVED SET OF PLANS. SERVICE UPGRADED TO 3000A WITH NEW SWITCH BOARD.  Plan check only for ""Delta 8"". *****     <<<<New 131 unit, 6-story apartment building, with 3 levels of underground parking.  Fees calculated per customer application.  Plan check for Power and Energy.  A variance to seperate the fire alarm system from the electrical system was submitted on May 24, 2012.>>>>>."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37348	18041-10000-41267	6642 N COLBATH AVE	91405	2	180B153   378	2238005014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.19164	-118.43658	NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 2.4KWdc /2.24KWac. PV SYSTEM IS  CONNECTING TO THE POINT OF INTERCONNECTION OF A SINGLE FAMILY HOME.(8)MODULES-SOLARWORLD SW 300(8)MICROINVERTERS-ENPHASE S280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37349	18041-10000-09906	1010 N SWARTHMORE AVE #5.102	90272	11	129B125   562	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.04752	-118.52548	"Full plan check for Initial TI (first time tenants) to existing retail space ""The Little Market"". Scope include new 30kVA transformer, New 100A panel for power and lightings. Total area: 671 sq.ft(B# 18016-10000-07418)"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37350	10041-20000-02455	8825 N KESTER AVE	91402	7	195B149   277	2653006***	OS-1XL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1175.10, 1175.20, 1193.40, 1201.02	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	04/12/2010 12:00:00 AM	ADDRESS	34.23088	-118.45762	Fire Alarm systemPanel change out , adding devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37351	14041-10000-14417	320 N AVENUE 64	90042	14	154-5A233 264	5493017022	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM			Corrections Issued	05/30/2014 12:00:00 AM	ADDRESS	34.11684	-118.17991	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37352	16041-10000-27270	4225 S CENTRAL AVE	90011	9	114A209   153	5115019033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.00695	-118.25669	PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT; EXISTING 2000A CORE AND SHELL SERVICE. ADDITION OF 3 NW PANELS. TOTAL AREA 2782 SQ FT.B# 16016-10000-18003.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37353	16041-10000-36005	1621 S MALCOLM AVE	90024	5	129B153    42	4325026021	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			10/14/2016 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.05355	-118.43747	SCOPE OF WORK INCLUDES PC FOR POWER AND ENERGY FOR A NEW 4-STORY APARTMENT BUILDING. SCOPE INCLUDES A 600A 120/240V 3PHASE 4 WIRE DISTRIBUTION/SERVICE BOARD. TOTAL SQ. FT. 4605	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37354	14041-20000-16506	5938 N JUMILLA AVE	91367	3	177B117   711	2153020028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Expired	08/23/2016 12:00:00 AM	ADDRESS	34.17859	-118.56375	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 7.6 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. CONNECT TO 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37355	13041-10000-29581	525 E ANAHEIM ST	90744	15	030B209     7	7423023006	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Expired	04/27/2016 12:00:00 AM	ADDRESS	33.78047	-118.25663	PC FOR POWER. INSTALL NEW 4160V U.G. cONDUIT AND NEW 1750HP WATER PUMP. power derived from an (e) spare 4160V switchgear cubicle. Wilmington Townlot facitily. Injection and charge pump installation. Classified/Hazardous location (Oil well). Motor cutsheets providedMETHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37356	18041-20000-24368	8900 N OAK PARK AVE	91325	12	195B133   205	2690008003	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Issued	06/29/2018 12:00:00 AM	ADDRESS	34.23245	-118.5053	PV1.  Install 9.9 kW DC roof mounted grid tied PV system.  (33) modules with 10kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37357	16041-20000-32085	1500 S BEVERLY DR	90035	5	129B165   261	4306015027	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			09/09/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.05226	-118.39516	INSTALLATION OF A NEW FIREALARM SYSTEM. 1 FACP AND 81 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37358	15041-10001-43896	6910 W GRENOBLE ST	91042	7	207B201   275	2553011010	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM			Reviewed by Supervisor	01/20/2016 12:00:00 AM	ADDRESS	34.26075	-118.28151	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALLL 4.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER X21-345(1) INVERTER: SOLAREDGE SE3800A-US 240>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37359	10041-20000-15717	10250 W SANTA MONICA BLVD #1010	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Plan check T-24 Energy for retail TI. Unit #1010	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37360	12041-10000-06034	8000 W SUNSET BLVD	90046	5	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.09783	-118.36466	new fire alarm, new panel, 435 devices,three story bldg, work all floors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37361	19041-10000-33383	18205 W SHERMAN WAY	91335	3	186B125   891	2119028015	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.20135	-118.52968	CHANGE OF USE FROM RETAIL TO VETERINARY CLINIC TENANT IMPROVEMENT (3752 SF). BULDING PERMIT: 19016-10000-08003	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37362	11041-20000-18592	510-516 S LANDFAIR AVE 1-37	90024	5	135B149   156	4363005046	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.04	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.0683	-118.4506	T.I.  New 36 unit apartment building.  Five story building.  Fire alarm will be submitted by a different person.  Full plan check.FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37363	15041-20000-27558	6269 E STRICKLAND AVE	90042	14	159A231   258	5483021008	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.12881	-118.18286	Plan check  for PV roof mounted system. System size: 3.8kW with 16 modules and 3.8kW inverter. Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37364	13041-10000-06868	9020 N SWINTON AVE	91343	12	195B137    91	2688003022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.23452	-118.48603	PV1 ROOF MOUNTED SOLAR INSTALLATION.  SYSTEM SIZE IS 4.8KW USING TRANSFORMERLESS INVERTER AND POWER OPTIMIZIER. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER # SOLAREDGE # SE50000A-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37365	19041-20000-26481	1921 S VIRGINIA ROAD	90016	10	126B185  1052	5061005003	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.03929	-118.33577	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM. SYSTEM SIZE IS 11.59KW DC/11.4KW AC. SCOPE OF WORK INCLUDES (38) LONGI PV MODULES WITH P320 OPIMIZERS AND A SE11400H-US INVERTERFees $71.99 due to California Senate Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37366	11041-10000-08646	9575 W PICO BLVD	90035	5	132A167   213	4330025006	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			Corrections Issued	04/28/2011 12:00:00 AM	ADDRESS	34.05537	-118.39753	T.I. FOR PICCA RESTAURANT.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37367	12041-20000-09508	16710 W VENTURA BLVD 1-125	91436	5	168B137   335	2289020019	(Q)C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM			PC Approved	05/02/2012 12:00:00 AM	ADDRESS	34.15819	-118.49729	Plan check for power. Retail store for Equinox Gym. 2414 sqft conditioned area. Plan check for energy was done under 12041-20000-06952.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37368	17041-10000-13072	1289 W 24TH ST	90007	8	123B197   477	5055017013	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.03449	-118.28875	Installation of a PV1 roof mounted solar system for a single family home. Adding 14 Microinverters rated for an output power of 320W. Total size: 4.48KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37369	15041-10000-06014	21710 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	09/06/2015 12:00:00 AM	ADDRESS	34.18735	-118.60204	FOR COSTCO STORE, NEW VEHICULAR FUEL DISPENSING STATION /UNDERGROUND FUEL TANKSCLASS I DIV 2 LOCATIONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37370	10041-10000-13974	2051 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM			PC Info Complete	07/20/2010 12:00:00 AM	ADDRESS	34.03969	-118.44283	TI IN RETAIL STORE. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37371	15041-20000-23739	20460 W VIA CELLINI	91326	12	219B109   262	2701055012	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Expired	08/31/2017 12:00:00 AM	ADDRESS	34.29511	-118.58101	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (23) modules. Being submitted because MSP is 300 Amp-rated.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37372	12041-10000-07099	8915 N STANSBURY AVE	91402	7	195B153   425	2639020007	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	34.23213	-118.44482	NEW ROOF MOUNTED 4.30 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37373	17041-10000-02700	20000 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.27519	-118.57042	FULL PLAN CHECK FOR CONSTRUCTION OF NEW 3 STORY MEDICAL OFFICE BUILDING. NEW LIGHTING AND POWER. CORE AND SHELL BUILDING, SERVICE RATED AT 1600 AMPS 277/480. 3PH 4W. AREA: 177,185.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37374	17041-10000-08531	926 E 21ST ST	90011	9	120A209    41	5131013003	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.0247	-118.25637	Installation for a new PV1 roof mounted solar system. 6.0 KW, 22 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37375	15041-10000-24672	20422 W SHERMAN WAY	91306	3	183B109   109	2136002002	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.20084	-118.57825	PV1 4.09KW roof-mounted system with (19) Enphase M215-Microinverters,  (19) Trina Solar TSM-255 modules interconnecting through a sub panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37376	17041-30000-19826	601 S FIGUEROA ST Suite 3000	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is the 30th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,745 sq. ft.Note: Building application has been generated under 17016-10000-14511	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37377	13041-10000-18751	544 W 130TH ST	90248	15	081B201   341	6132003031	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	33.91429	-118.28468	Plan check power upgrade to 600 A service for existing commercial furniture manufacturing building. Refeed existing panels, transformers, and equipment to new switchboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37378	19041-10000-41248	1305 N VERMONT AVE	90027	13	147B197  1039	5543014012	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/15/2020 12:00:00 AM		Permit Finaled	04/16/2021 12:00:00 AM	ADDRESS	34.09588	-118.29206	full plan check for Tenant improvement and exterior renovation to (E) restaurant. all  panels are new to an existing (600A) switch gear. existing service size 600A,208/120V, 3ph, 4 wire. area of scope 2382sf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37379	11041-20000-01978	1823 W SAN FERNANDO ROAD	90065	1	148-5A215 112	5442004013	[Q]MR1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.01	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.09963	-118.23469	T.I. from industrial space to a bakery shop.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37380	16041-20000-36380	12311 W SHERMAN WAY	91605	2	183B165    19	2307021006	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.20136	-118.40138	remove existing hid fixtures and replace with new led indoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37381	15041-10000-39499	843 N WILCOX AVE	90038	4	141B185    62	5533026024	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			11/23/2015 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.08647	-118.33126	PC FOR ENERGY AND POWER. NEW APARTMENT BUILDING WITH 4-STORY , 8 UNITS AND ONE PARKING LEVE. 3 TYPICAL UNITS. TOTAL  AREA 7378 SQ INDOOR + 3270 SQ FT OUTDOOR.FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37382	15041-10000-28442	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.98489	-118.42552	REPLACE 16 BATTERY DC BREAKERS LIKE FOR LIKE.PLAN CHECK PER APPLICANR REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37383	15041-30000-39781	5015 N BALBOA BLVD #101-#410	91316	5	171B133   627	2258016***	(T)(Q)R3-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Apartment			11/24/2015 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.16219	-118.50134	New fire alarm system located in fully sprinklered 4 story, Type V-A, 42 unit apartment with two level, Type I-A, basement garage.   202 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37384	14041-10000-35125	1615 S GLYNDON AVE	90291	11	114B149  1151	4244019027	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.00431	-118.45584	PV1 roof mounted system size 6kW with 3 string and 32 modules and 1 inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37385	11041-20000-20922	6101 N VARIEL AVE	91367	3	177B105    52	2149005045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			09/30/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.18081	-118.59299	POWER AND ENERGY FOR EXISTING BUILDING CORE & SHELL. TWO EXISTING SERVICES SERVING BUILDING. NEW CKTS AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37386	19041-10000-18881	4616 S BROADWAY	90037	9	112-5A203 342	5110008029	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.00147	-118.27811	CHANGE OF USE FROM RETAIL TO OFFICEFULL PLAN CHECK-EXISTING SERVICE;NEW PANELS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37387	14041-20000-21543	8451 N CALVIN AVE	91324	12	192B117   373	2783006006	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.22395	-118.55587	New roof mounted PV system with Optimizers.  Total system size is 3.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37388	15041-20000-01315	1418 W 82ND ST	90047	8	099B193  1298	6034013009	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.96448	-118.30101	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. THIS IS A CHANGE IN THE SYSTEM. USING 12 MODULES. THIS IS NEW PERMIT FOR NEW SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37389	17041-10000-17652	1227 W 60TH ST	90044	9	105B197   324	6003012020	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	33.98598	-118.29679	PV, INSTALLATIONOF A NEW 2.65 KW DC ROOF-MOUNTED SOLAR IN ON A DWELLING HOUSE.(10) MODULES: AXITPOWER AC-265P/156-60(1) INVERTER: FRONIOS PRIMO 3.8-1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37390	19041-30000-09331	2049 S CENTURY PARK EAST 33rd Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is common area restrooms on the 33rd floor. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37391	19041-20000-36895	23251 W MULHOLLAND DR	91364	3	168B093   229	2074039031	(Q)CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.15499	-118.63293	PV2. INSTALL 203.19 KW DC ROOFMOUNTED SOLAR SYSTEM WITH (521) HANWHA Q-CELL MODULES AND OPTIMIZERS. SCOPE OF WORK INCLUDES (2) SOLAR EDGE SE100KUS INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37392	11041-20000-04481	3511-3523 S CENTINELA AVE	90066	11	114B153   437	4246006001	[Q]C1-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00, 2721.00	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	03/05/2012 12:00:00 AM	ADDRESS	34.01021	-118.43874	Electrical plan check for core & shell of existing building.  Install new 800A service,  panels, and feeder.  Branch circuits and lighting will be under separate permit.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37393	15041-10000-27677	12238 W VENTURA BLVD	91604	2	162B165   235	2369004029	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.14293	-118.39984	PC for energy only. t-24, TI to an existing commercial bldg. (retail store to barbershop). Scope includes: relocation of 200 amp panel, and new lighting. sq ft = 1731.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37394	16041-10001-42851	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE UPDATE SERVICE FROM 2000A TO 4000A SERVICE RATED AT 480/277 WITH NEW FAULT CURRENT RATED AT 72KAIC, NEW TRANSFORMER INSTALLATION FOR EV CONNECTING WITH ESTIMATED LOAD OF APPROX. 300A, AND UPDATED LOAD SUMARY WITH REVISED ENERGY CALCULATIONS - CHANGES UNDER DELATA 5 ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37395	16041-10000-14544	1311 W WASHINGTON BLVD	90007	1	126A201   107	5056011027	C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	02/25/2017 12:00:00 AM	ADDRESS	34.04017	-118.28441	TI. to (e) McDonalds. Install new lights on dininga area, restrooms, and build. facade.  PC for T-24 only. Total area 1580 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37396	10041-10001-19754	13520 W PAXTON ST A-2	91331	7	210B157  1074	2535002015	M3-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			PC Approved	01/07/2011 12:00:00 AM	ADDRESS	34.27356	-118.42606	FIRST TENANT- PANDA EXPRESS RESTAURANT; TITLE 24 PLAN CHK APPROVAL OBTAINED ON 10041-10000-19754	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37397	18041-20000-17412	4770 W CROMWELL AVE	90027	4	153B197   536	5588016017	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.11244	-118.29351	Plan check for battery PV roof mounted system with battery back up system. System size: 7.6kWac with 30 modules and 1 inverter(7.6kWac) connected to battery LG9.8kWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37398	17041-10000-24768	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.09786	-118.29745	EQUIPEMENT REPLACEMENT IN MEDICAL OFFICE BUILDING. PROVIDING UPDATED LIGHTING, T24 AND SOME MEDICAL EQUIPEMENT. PC FOR POWER AND ENERGY. PATIENT ARE AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37399	18041-20001-08717	7900 N BALBOA BLVD ' B '	91406	6	192B137   311	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	10/3/2018changes to an approved set of plans.  changes to reflect current field conditions delta 2 changes only. this is plan check only.   ((((PLANCHECK FOR POWER AND ENERGY.  NEW 27760 sf aircaraft hangar, building 'B':BUILDING PERMIT : 170102000001606))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37400	13041-20000-20690	1011 S FIGUEROA ST	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.04476	-118.26452	RENOVATION OF EXISTING RESTAURANT. NEW 150KVA TRANSFORMER, PLACE OF ASSEMBLY. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37401	15041-20000-11745	6250 N TOPANGA CANYON BLVD F-1505	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	T. I to new commercial building (restaurant and bar). Plan check for power and energy. Total sqft. 3200	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37402	19041-20000-51292	19231 W VICTORY BLVD	91335	3	180B117   799	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	07/31/2020 12:00:00 AM		Permit Finaled	08/10/2022 12:00:00 AM	ADDRESS	34.18678	-118.55214	$0 PERMIT FEE DUE TO SB1222 AND AB1414PV3.  INSTALLING (3) NEW ROOF MOUNTED PV SYSTEMS AT (3) INTERCONNECTION POINTS.SYSTEM 154.4 KW DC/48.903 KW AC CECSYSTEM 268.328 KW DC/68.328 KW AC CECSYSTEM 327.2 KW DC/24.451 KW AC CECSCOPE OF WORK CONSISTS OF (395) PV MODULES, (3) 22.7 KW INVERTERS, (4) 15 KW INVERTERS, AND (2) PANELS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37403	19041-10000-52969	12580 W SATICOY ST	91605	2	186B161   405	2305025022	M1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.2075	-118.40783	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37404	15041-10000-38358	11017 W OLINDA ST	91352	6	192B173   208	2408018042	M2-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.22442	-118.37091	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37405	15041-10001-28391	13841 W PADDOCK ST	91342	7	228B153   568	2503007024	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.31775	-118.43524	Supplemental to permit# 15041-10000-28391. Adding branch circuit to the PV Monitoring system. Zero additional fee ($0) due to California Senate Bill 1222.<<PV1INSTALL ROOF MOUNTED PV SYSTEM (ACM) SYSTEM SIZE 5.7KW INTERCONNECTED WITH MSP.(20) LG ELECTRONICS LG300N1C-B3(20) LG ELECTRONICS LM305UE>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37406	19041-20000-41435	1630 N SAN PABLO ST	90033	14	135A225   143	5202001011	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM	ADDRESS	34.06498	-118.20218	PV3 PLAN CHECK NEW ROOF PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS 36.225 KW DC/43.2 KW AC. SCOPE OF WORK CONSISTS OF (105) PV MODULES WITH 56 OPTIMIZERS AND (1) 43.2 KW INVERTER.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37407	17041-10001-00305	400 W WORLD WAY	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	PIN	33.94340087	-118.39046685	Changes to approved set of plans, changes under clouded area. Type of light fixture change. T-24 updated. Area: 892 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37408	13041-20000-10803	333 S GRAND AVE 6th fl	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	energy plan check 6th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37409	16041-10000-01158	450 S WESTERN AVE # 213	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM			PC Info Complete	01/13/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	Change of use of portion of (E) retail building from retail to bank. PC for Energy only, 995 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37410	17041-20000-35816	24034 W SCHOENBORN ST	91304	12	192B089   151	2017037019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.22118	-118.65019	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (24) modules. PV system is interconnecting to a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37411	18041-20000-25363	8330 N LOUISE AVE	91325	12	192B133   232	2690017112	RE11-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Closed	12/05/2019 12:00:00 AM	ADDRESS	34.22187	-118.50965	PV1.  Install 11.285 kW roof mounted grid tied PV system.  (37) modules with 4.2 and 5.0 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37412	17041-10000-09848	555 W 5TH ST 37TH FL.	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC for energy only, Indoor Title 24. TI at corridors, elavator lobby, and restrooms on 37th floor on existing highrise building. Area: 2410 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37413	09041-10002-21197	1511 N WILCOX AVE	90028	13	147A187   100	5547017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	09/20/2011 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	34.09839	-118.33114	REVISED PERMITTED SET OF PLANS: NEW FEEDER TO SUPPLY THE ELEVATOR; NEW PANELBOARD TO SUPPLY NEW 5KVA INVERTER (EMERGENCY SOURCE) FOR THE EM AND EXIT FIXTURES IN THE CORRIDORS; EXIT SIGNS PROVIDED WITH NORMAL SOURCE; NEW CKTS ADDED TO PANEL A(((((((((SUPPLEMENTAL TO PERMIT #09041-10000-21197 TO CHANGE ADDRESS FROM 6501 W SUNSET BLVD TO 1511 N WILCOX AVE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37414	12041-10000-19974	1032 S CRENSHAW BLVD C1-C2	90019	10	129B189    73	5081004024	C2-1-O	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Expired	09/22/2014 12:00:00 AM	ADDRESS	34.0536	-118.32335	Re-feed two sub-panels from house panels to main switchboard (to be rated at 22k AIC), no change to physical location.  Full plan check requested by applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37415	18041-10000-31990	4371 S GLENCOE AVE #B-6	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	33.9857	-118.43834	PLAN CHECK FOR POWER AND ENERGY - CHANGE OF USE FROM RETAIL TO YOGA STUDIO. ASSEMBLY OCCUPANCY EXCEEDING 100 OCCUPANCY LOAD.  - 3439 SFBUILDING PERMIT # 18016-10000-27054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37416	14041-10001-09761	1075 N VILLA GROVE DR	90272	11	129B129   356	4409006014	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/19/2014 12:00:00 AM	ADDRESS	34.04995	-118.51364	Expedited RSES plan check per applicant request.{{PV1, Install 6 kw DC roof-mounted solar array on a one-story home, interconnect with main service panel.(1) Transformerless Inverter: SOLAREDGE SE6000A-US-ZB-U(24) Modules: CANADIAN SOLAR CS6P-250X}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37417	18041-20000-34843	4530 N TYRONE AVE	91423	4	168B153   735	2265017013	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.1538	-118.44419	Plan check for PV roof mounted system, system size: 12KW AC, 11.711KW AC CEC with 38 modules and 2 inverters(6.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37418	17041-30000-32632	3420 N EAGLE ROCK BLVD #A - C	90065	1	153A215    97	5457022020	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.1145	-118.23591	Plan check for Title 24 only in existig space T.I. retail. total load is less than 400A. Total area: 6,699 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37419	13041-10000-13204	9945 N HELEN AVE	91040	7	201B177    48	2542010035	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.25119	-118.36586	PV1 ROOF MOUNTED SOLAR INSTALLATION (INSTALLED ON A DETACHED GARAGE) ON A NON STANDARD PLAN. SYSTEM SIZE IS 9 KW DC. [INVERTER: FRONIUS # IG PLUS V 7.5-1UNI  |||| MODULES: TRINA SOLAR # TSM250-PC05] investigation fee due	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37420	17041-20002-32256	7253 N LURLINE AVE	91306	3	186B109   974	2113015006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.20263	-118.58426	10.6.2017 - Plan check for modifications to approved set. Changing location of Inverters and load center (to south exterior wall) - see sheet PV-2.0. Change clouded. ONLY CHANGE.======Plan check for solar pv system, roof-mounted on SFD.7kW ungrounded system [(1) 4kW + (1) 3kW].(26) 285W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37421	17041-30000-09846	7373 W BEVERLY BLVD	90036	5	138B181   398	5526037016	C2-1VL-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.07631	-118.35069	Title 24 plan check.  TI and change of use from retail to office.  All subpanels to remain existing.  New lighting and receptacle loads.  Total area = 5,435 sq. ft.Building permit #17016-40000-00589	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37422	19041-10000-51268	11227 N CARRILO DR	91345	7	210B145   527		P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	34.27437	-118.46862	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 13 MODULES (HANWHA Q.PEAK BLK-G5315), 13 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)SYSTEM SIZE: 4.095 KW DC;  3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37423	19041-20000-18460	12100 N BELLANDO CT	91344	12	219B125    87	2601073016	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.29351	-118.52577	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 13.53KW DC/13.12KW AC. SCOPE OF WORK IN CLUDES (41) PANASONIC PV MODULES WITH ENPHASE IQ7X MICROINVERTERS, A COMBINER BOX, AND A 200A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37424	18041-10000-07116	11936 W DARLINGTON AVE 1-20	90049	11	129B145   643	4265009053	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	34.04914	-118.46825	PC for T24 only for lighting alterations in corridors of apartment building. Replacing existing lights with new LED lights. Total 5640 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37425	19041-10000-02726	863 S WELLESLEY AVE	90049	11	129B141   620	4264016026	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.04589	-118.4754	NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 3800 INVERTER AND (14) MODULES + OPTIMIZERS. TOTAL SYSTEM SIZE IS 3.8KWAC AND 4.2KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37426	13041-10000-26309	8048 W 3RD ST	90048	5	138B177   753	5511028012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.07192	-118.36544	PLAN CHECK POWER AND ENERGY FOR RESTAURANT TENANT IMPROVEMENT IN EXISTING BUILDING. EXISTING 1600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37427	18041-20000-21860	11822 W ELKWOOD ST	91605	6	189B169   620	2310023006	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.21286	-118.39084	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (22) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37428	14041-10000-25428	14736 W KESWICK ST	91405	6	186B149    28	2210028024	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.21014	-118.45429	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 7755 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37429	12041-10000-18530	2917 W PICO BLVD	90006	1	129B193  1239	5080027014	[Q]C2-2	Central	Wilshire	Olympic Park		2132.02, 2212.10	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.04736	-118.30372	remodel offices and rest room at the Pico Auto Shopplan chk is for Title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37430	11041-10000-26581	5400 W CENTURY BLVD FITNESS-CENTER	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	33.9451	-118.37436	PLAN CHECK T24 ENERGY FOR TI--REMODEL FITNESS ROOM ON 3RD FLOOR WITHIN HOTEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37431	18041-10000-39858	11428 W SHERMAN WAY	91605	2	183B169   683	2320001022	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.20103	-118.37983	PLAN CHECK FOR COSTCO DUE TO CHANGE OF DESIGN FROM ORIGINAL SUBMITTAL (18041-10000-24350). NEW EQUIPMENT AND CKTS ALSO ADDED. ALL CKTS AND EQUIPMENT FEE WILL BE UNDER INSPECTION FEE ONLY. BUILDING PERMIT: 18016-10000-20836	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37432	11041-10000-21137	8500 W BEVERLY BLVD #757	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM	01/04/2012 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I. TO AN EXISTING 2,131 S.F. RETAIL SPACE; DEMO OF NON-STRUCTURAL WALLS, CEILING & RELOCATION OF RESTROOM; WORK TO INCLUDE NEW NON-STRUCTURAL WALL, NEW CEILING, MILLWORKS & RELOCATION OF RESTROOM; NO CHANGE IN USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37433	13041-10000-01076	6217 W WARING AVE 1-23	90038	4	141B185   263	5533026008	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.08538	-118.33155	New apartment building 4 stories plus sub terrain garage. 23 units. 1000 A main service. 30000 sqrft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37434	19041-10000-07707	4876-4878 W FOUNTAIN AVE	90029	13	147B197  1157	5540012002	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.0953	-118.29579	"T-24 PC FOR A CHANGE OF USE FROM ""RETAIL"" TO ""BEER AND WINE BAR"".  TOTAL CONNECTED LOAD IS LESS THAT 400A. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 704 SQ.FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37435	14041-10000-20419	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	Title 24 plan check only.  Total area = 3,029 sq. ft.TI to existing retail space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37436	19041-20000-16241	20757 W LUGANO WAY	91326	12	213B109   344	2701065042	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.27839	-118.58557	Plan check for Energy Stroage Battery back up system install into existing PV system, Battery system size: 13.5kW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37437	17041-20002-32539	7283 W PACIFIC VIEW DR	90068	4	156A181   577	2428017004	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Expired	10/01/2023 12:00:00 AM	ADDRESS	34.12057	-118.35109	Revisions to approved plan.  Change of interconnection details.  $0 permit and plan check fee per State Senate Bill SB 1222(((Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters and (50) modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37438	16041-10000-34522	4534 N DULCINEA CT	91364	3	165B101   168	2173015003	RE15-1-RPD-2.9-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2016 12:00:00 AM			Reviewed by Supervisor	10/13/2016 12:00:00 AM	ADDRESS	34.15048	-118.60627	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.20KWac.(35)AC MODULES-SUNPOWER E20-327C-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37439	16041-20000-07253	23640 W VICTORY BLVD	91367	3	180B093   854	2035008020	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.18641	-118.64188	Plan check for energy only. TI to restaurant (Mission Burrito). New lighting (emergency is existing). 1,490sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37440	16041-20000-21583	3627 N CODY ROAD	91403	4	159B145    65	2278024004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.1361	-118.46394	PV1. ROOFMOUNTED SOLAR SYSTEM . MICROINVERTERS. SYSTEM SIZE: 17.05 KW.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37441	17041-20001-32093	420 E 20TH ST	90011	9	121-5A207  51	5127018011	[Q]CR-1VL-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.02826	-118.2617	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 12.5 kWac and consists of (1) inverter and (42) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37442	16041-10001-07976	17331 W PARTHENIA ST	91325	12	195B129   402	2768016005	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.2287	-118.51244	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, NEW 15.70 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(48) MODULES: SUNPOWER SPR- E20-327-C-AC(48) MICROINVERTER: SUNPOWER E20-327-C-AC-GEN 2.2>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37443	19041-10000-31809	1125 S BEVERLY DR #525	90035	5	132A167    97	4330026010	C2-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Issued	08/14/2019 12:00:00 AM	ADDRESS	34.05685	-118.39673	Power plan check for a dental office T.I. Scope includes (7) ckts for new equipment and outlet located in (3) exam room. Note. Portion of permit fee is paid under 19041-20000-28960.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37444	18041-10000-45882	12121 W BLUFF CREEK DR STE  250	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	33.97874	-118.40463	T-24 ONLY FOR EXISTING BALCONY OF TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37445	17041-10000-11560	1245 W WILSHIRE BLVD #775	90017	1	132A207   288	5143017041	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	Full plan check for a general doctor  medical office T.I. Scope includes new lighting, receptacle and equipment. Total area is 2030 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37446	13041-10000-28379	734 N LA CIENEGA BLVD	90069	5	141B173   308	5528001064	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.08459	-118.37633	Addition to (E) 1-story retail/gallery w/ mezzanine, addition of 2nd floor offices.  New main switchboard and other power distribution equipment.  Plan check for power and energy. Changes: includes addition of bugeyes in gallery 3, bugeyes on same ckt as general ltg.Plan check fees adjusted to meet applicant's check amount.  Full submittal fees to be recalculated at 34 branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37447	14041-20000-05755	12113 N BEAUFAIT AVE	91326	12	219B121   410	2870005016	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.29294	-118.53879	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.28KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37448	11041-10000-15366	6411 W IMPERIAL HWY	90045	11	087B165    12	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.93238	-118.3989	fule station for atlantic aviation center. lighting , dispensers, new panel, new xfmr, new branch ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37449	13041-20000-03577	11912 W LAURELWOOD DR	91604	2	162B169   311	2369017010	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.14191	-118.39187	New 9-unit apartment building.  Full plan check.   Variance to separate fire alarm has been paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37450	17041-10000-16645	1022 W LOMITA BLVD	90710	15	036B197    41	7413017019	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.7976	-118.29349	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 16550 SQ FT. OUTDOOR/INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37451	15041-10000-00425	5168 E HUNTINGTON DR SOUTH	90032	14	144A235   165	5219001035	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.08911	-118.16978	Installation of new sprinkler monitoring system for existing commercial space.  Total system size = 22 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37452	10041-10000-17697	229 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			Corrections Issued	09/19/2010 12:00:00 AM	ADDRESS	34.04926	-118.22589	Solar voltaic system installed on the roof of the building.  Consists of  6 modules,  6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37453	14041-20000-15613	5143 N VINCENT AVE	90041	14	163-5A225 288	5669017011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.14078	-118.20234	PV1Microinverter standard plan.Install roof-mounted solar array on SFD. System size: 2.8kW(13) EnPhase M215 microinverters(13) Sun Module SW-250 MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37454	17041-10000-43418	5302 N QUAKERTOWN AVE	91364	3	171B113   172	2166004007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.16625	-118.56945	Plan check for PV roof mounted system. Total system size: 10kW with  41 modules and 1 inverter(10kW) connected to MSA.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37455	18041-20000-08168	167 S ROCKINGHAM AVE	90049	11	132B137   570	4406016009	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.0552	-118.49281	Plan check for power only. Project site is a new 3-story single-family dwelling. Work includes a new 600-amp service.Note: Building permit has been issued under 16010-30000-03069 this is a combo permit.Plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37456	10041-20000-08928	21255 W BURBANK BLVD #270	91367	3	174B105    22	2149019006	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	ADDRESS	34.17432	-118.59446	Plan check T-24 Energy (general/emergency) lighting for TI in Suite #270. Non-highrise building with emergency generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37457	19041-10000-21398	1914 W 8TH ST	90057	1	130-5A203  14	5142004025	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			Corrections Issued	06/21/2019 12:00:00 AM	ADDRESS	34.0539	-118.27611	PC FOR NEW 4-STORY MIXED USE BUILDING WITH THREE STORY TYPE V-A, 18 UNIT APARTMENT OVER FIRST STORY TYPE IA PARKING GARAGE AND RESTAURANT/OFFICES AND ONE LEVEL BASEMENT PARKING GARAGE WITH RECREATION ROOM. SERVICE SIZE IS 1600A,120/208V,3PH, 4W. SCOPE AREA 20,000SF (NO ELECTRICAL STAMP)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37458	14041-10000-03062	2121 S AVENUE OF THE STARS SUITE 2300	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	PLANCHECK FOR T24 ENERGY. OFFICE TENANT IMPROVEMENT, NO CHANGE IN OCCUPANCY. 17909 SQFT, EMERGENCY LIGHTING. HIGHRISE. SUITE 2300 ON 23RD FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37459	14041-10001-11716	14818 W CALAHAN ST	91402	6	198B149   518	2651005011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.23626	-118.45616	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZEER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(23) MODULLES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37460	16041-20000-43762	14725 W ARMINTA ST	91402	6	189B149   476	2210021012	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.21367	-118.45391	Plan check for energy only. TI to office building. New lighting (incl. emergency) and receptacles. 9,727sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37461	16041-10000-01112	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	33.93195	-118.41136	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE FIRST FLOOR. SCOPE INCLUDES REMOVING SOME EXISTING LIGHTING FIXTURES, AND ADDING A 1,182 SQ. FT. WALK IN COOLER. TOTAL AFFECTED AREA IS 1182 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37462	14041-10000-13542	11021 W TUXFORD ST	91352	6	195B173    55	2408033041	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Expired	07/07/2016 12:00:00 AM	ADDRESS	34.23412	-118.37224	Remove HID light fixture and replace with new flourescent	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37463	12041-10000-27557	418 N EAST EDGEWARE ROAD	90026	1	136-5A209 348	5160020051	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.06619	-118.25477	PC FOR T24. TI TO EXISTING APARTMENT. 7053 SF. 4 STORY APT EXPANDING LEASING ROOM AND ADDING BATHROOM AND LANDSCAPE LIGHTING. METHANE ZONE BUT NO WORK UNDERGROUND.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37464	12041-10001-09773	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Public Safety Only			07/10/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	33.94386	-118.4047	DELTA 2 CHANGES TO PERMITTED SET OF PLANS;  UPGRADE POWER EXPANDERS AND DECREASE SMOKE DECTORS AS PART OF CHANGES IN SMOKE DETECTION IN ROOMS 123,141 AND 148 NEW FIRE WARNING SYSTEM FOR THE NEW  CENTRAL UTILITY PLANT BUILDING AT LAWA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37465	19041-20000-06218	16055 W VENTURA BLVD Suite 120	91436	5	168B141   524	2261022023	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.15653	-118.4831	Plan check for power only. Project site is an existing outpatient surgical center in commercial high-rise building. Project scope is the addition of emergency panels and the separation of existing circuits into their respective panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37466	16041-20001-33970	2731 W SOUTHWEST DR	90043	8	105B189  1567	4007020009	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/05/2016 12:00:00 AM	ADDRESS	33.98075	-118.32354	Plan check for 4.93 kW roof-mounted PV system per inspector's request.  (11) modules on detached structure, (6) modules on main residential structure.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37467	17041-10000-28700	3785 W WILSHIRE BLVD #223	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Issued	08/21/2017 12:00:00 AM	ADDRESS	34.06187	-118.30858	PLAN CHECK FOR T24 ONLY, TI OF EXISTING OPEN OFFICE SPACE  ON THE 2ND FLOOR, AREA 1,005 SQ.FT  (B#17016-10000-19151)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37468	18041-10000-41666	14312 W FRIAR ST	91401	6	177B153    40	2240011010	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.18556	-118.44479	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37469	09041-20001-22886	3200 E UNION PACIFIC AVE	90023	14	118-5A223 213	5169002016	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM			PC Approved	03/23/2010 12:00:00 AM	ADDRESS	34.01686	-118.21065	INSTALLATION OF SOLAR SYSTEM IN COMMERCIAL BUILDING. reviousion to previouly approved plan. Change has been drewn the plan according to the way it has been installed different location of  fed to the MS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37470	10041-20001-18350	2580 N GLENDALE BLVD	90039	4	150A209   185	5438016002	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	11/19/2010 12:00:00 AM	ADDRESS	34.10497	-118.25927	Plan check for car wash equipment loads in MCC. Electrical system plan check approved, which did contain only design (future) loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37471	18041-10000-30239	2025 W 3RD ST	90057	13	135A205   238	5154020031	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.06289	-118.27215	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37472	13041-10000-05790	8049 S DUNFIELD AVE	90045	11	099B165   580	4109010006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	33.96719	-118.39912	photovoltaic system for single family dwelling. TOTAL SYSTEM SIZE 5.6KW. USING ENPHASE M215 MICROINVERTER. USING LG 260 SOLAR MODULES. 26 MODULES IN TOTAL. STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37473	17041-10000-31273	633 W 5TH ST 11TH FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	TI FOR OFFICE SPACE OF THE ENTIRE FLOOR; ADDING INTERIOR PARTITIONS, SUSPENDED CEILING AND FINISHES. 20,000 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37474	18041-20000-15842	20633 W CHESTNUT CIR (#272)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	12/29/2018 12:00:00 AM	ADDRESS	34.29334	-118.58365	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37475	16041-10000-25934	5279 W OLYMPIC BLVD	90036	4	132B181   673	5084004009	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.05738	-118.34546	Plan check for Title 24 for 2537 sqft. Installing new lights and receptacles. Newly connected load less than 400 A.**NEW STORE FRONT DOORS AND WINDOWS (EXISTING BUILDING).  RESTUCCO PORTION OF BUILDING. (PARKING LOT RESTRIPING UNDER SEPARATE SUBMITTAL).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37476	12041-10000-06377	16952 W BLANCHE PL	91344	12	219B133   513	2609026025	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2012 12:00:00 AM			Reviewed by Supervisor	05/25/2012 12:00:00 AM	ADDRESS	34.2955	-118.50128	New 11.04kw rooftop photovoltaic system for an existing sfr with two inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37477	17041-20002-40205	6927 N REMMET AVE #C	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM			PC Approved	05/10/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	05/10/2018 Changes to an approved set of plans. All changes have been clouded. PV system has be redesigned. System size is 3.3 kWac and consists of (1) inverter and (9) modules. *****Previous Work Description*****Plan check for solar pv system, roof-mounted array on 3-unit apartment.3kW ungounded system. (9) 280W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37478	14041-10000-13419	721 E 12TH ST # 3	90021	14	124-5A211 307	5132012106	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.03348	-118.25258	T24, Remove HID light fixtures and replace with new fluorescent fixtures. Total area 288 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37479	14041-20001-07934	15831 W SIMONDS ST	91344	12	213B141   414	2666011020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.2765	-118.4773	Fee for expedite only.****Roof mounted PV system with tranformerless.  System size 5.2KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37480	18041-20001-16642	13271 N GLENOAKS BLVD	91342	7	225B149   332	2505001029	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2018 12:00:00 AM			PC Approved	05/15/2018 12:00:00 AM	ADDRESS	34.31207	-118.45576	Expedite per appicant requestPlan check for PV roof mounted system, System size: 13.1kW with 38 AC Modules connected to 400A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37481	18041-10000-02507	640 N SEPULVEDA BLVD	90049	5	138B145   113	4368016071	[Q]C2-1VLD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.0769	-118.46861	PC for T24 only for new outdoor and facade lighitng. Installing new outdoor light circuits. Total area 5920sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37482	16041-20000-08865	6324 W 85TH PL 1-24	90045	11	096B165   468	4108019019	[Q]R3-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	33.96032	-118.39734	PV2.  Install 13.6 kW roof-mounted PV system.  (2) 6000W inverters with (44) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37483	12041-20000-12772	1181 N VIRGIL AVE	90029	13	145-5A201 239	5542026022	R2-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Apartment			06/04/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.09322	-118.28673	Enphase photovoltaic system on the roof of apartment buildings.  Building B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37484	15041-20000-28683	5700 W WILSHIRE BLVD unit 600	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	TI to existing commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 15,376.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37485	17041-10000-02134	7032 S RAMSGATE PL	90045	11	102B173   397	4103011016	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			01/23/2017 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	33.97338	-118.37312	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 3 STORY 9 UNIT APARTMENT BUILDING. SCOPE INCLUDES 49 FA DEVICES, AND  3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37486	19041-10000-41724	22816 W MARLIN PL	91307	12	183B097   522	2026022010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.19669	-118.6241	$0 fee due to AB1414. [EPLAN] Revision to 19041-10000-34186. CHANGES INCLUDE RELOCATION THE INVERTER AND AC DISCONNECT AS INDICATED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37487	16041-10008-34516	6677 W SANTA MONICA BLVD	90038	4	144B185   674	5532022010	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM			PC Approved	07/15/2019 12:00:00 AM	ADDRESS	34.09085	-118.33573	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 3A ONLY. SCOPE INCLUDES REVISION TO SHORT CIRCUIT CALCULATIONS AND AIC RAGTING WITH SERIES RATING COMBO. ALSO SPLICES TO CONNECT TRANSFORMER LUGS. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER.<<<Plan check for Power and Energey for (new) 695 units apartment with 24,900 SF of retail, 5 stories. There are (5) services in compliance with article 230.2(C).>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37488	16041-30000-40030	4574 S CENTINELA AVE	90066	11	108B157   887	4232026048	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	33.99165	-118.42143	Plan check for Title 24 only in exising space for take out coffee shop. Total area: 1,464  sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37489	09041-10002-24398	5500 W SUNSET BLVD	90028	13	147A193   108	5544029011	C2-1	Central	Hollywood	Hollywood Studio District		1909.01, 1911.10	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.09793	-118.30958	Supplemental changes to previously approved plans.  Changes include light mounting height, replace light fixtures, relocated equipment, relocate conduits, and additional CU units.  All changes indicated by DELTA  date 12/28/13.NOTE:  This is plan check only.  The permit is under the previous application.*****CONSTRUCTION OF NEW 3 STORY RETAIL BUILDING AND PARKING AREAS ( TARGET STORE )VARIANCE HAS BEEN SUBMITTED TO SEPARATE THE FA PLANSCOMPLY WITHDEPARTMENT ORDER effective date 04/19/2011. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE. All permits shall be for the same timeperiod limitation. If additional assistance is needed, pleasecall Inspector BEN MATHIAS at (213)252-3959.  CEIS Case Number is413764.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37490	11041-10003-09464	8500 W BEVERLY BLVD #820	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	04/12/2012 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	Modification to previously approved set of plans.  Panels are changed from fully rated, new circuits and loads, different transformers are being installed.<<<TENANT IMPROVEMENT TO (E) RETAIL SPACE (#820):  (N) INTERIOR NON-BEARING WALLS, CEILING SYSTEMS, MILLWORK AND FINISHES TO CREATE SALES AREA, STORAGE, RESTROOMS AND FITTING AREAS.  INCLUDES REMOVING ESCALATOR, ENCLOSURE AND PIT.  (26,363 SF)>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37491	19041-20000-04699	11544 W VENTURA BLVD	91604	2	162B169   610	2369036003	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.13966	-118.38331	Plan check for 6 exit signs in childcare facility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37492	19041-10001-14908	17183 W SUNBURST ST	91325	12	195B133    30	2690001007	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.23461	-118.50843	"DELTA ""2"" Changes to approved plans for relocatng the PV equipment from the North side of the bulding to the East side. Plan Check Only.  Permit Number: 19041-10000-14908<<<pc for pv. system include (21) modules (panasonic VBHN330SA17), 1 central inverter (solaredge 6000H) and (1) 225A load center. system size is 6.93KW.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37493	11041-20001-21707	8635 W 3RD ST #580	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM			PC Approved	01/12/2012 12:00:00 AM	ADDRESS	34.07373	-118.38073	Modification to lighting system in previously approved dental office.  Reviewed for T24 lighting and emergency lighting.  No change in power.  Existing permit, # 11041-20000-21707.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37494	11041-20000-26791	10252 N NORRIS AVE	91331	7	204B165    78	2537003044	QMR1-1VL, [Q]M1-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.25638	-118.4019	T24 lighting plan check for a remodeled office conference room.  Electrical permit to be issued for  1 lighting circuit, and 19 units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37495	17041-10001-08198	3800 W MT LEE DR	90068	4	159B189    10	5581010900	OS-1XL, RE40-1-H	Central	Hollywood	Hollywood United	YES	9800.09	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.13546	-118.3184	Installation of new fire alarm system in existing commercial space.  Total system size = 36 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37496	14041-10000-03884	5880 W 75TH ST	90045	11	102B169   298	4104013011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	33.9731	-118.38547	fire approval requiredPV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. POWER OPTiMIZERS. ONE STORY. SYSTEM SIZE: 6.25 KW DC.(25) CANADIAN SOLAR # CS6P-250PX(25) SOLAREDGE OP300(1) SOLAREDGE SE6000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37497	18041-10000-33285	550 S HOPE ST 22ND FLR	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT WORK ON APPX 1592 SF OF THE TOTAL FLOOR AREA: CORRIDOR WALL. ELEVATOR LOBBY, AND RESTROOM(B# 18016-10000-19509)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37498	18041-10000-12192	900 W OLYMPIC BLVD #F51	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Issued	05/11/2018 12:00:00 AM	ADDRESS	34.04526	-118.26611	NEW SOLAR ROOF SYSTEM ON A HIGH RISE RITZ HOTEL/RESIDENTIAL. THIS PV IS ONLY FOR (1) UNIT PENTHOUSE (#F51). INSTALL (10) MODULES, (1) CENTRAL INVERTER SE7600A-US, (1) 10KVA TRANSFORMER 120/240V TO 208V. SYSTEM INTERCONNECT AT 600A SUBPANEL. SYSTEM SIZE AT 7.6 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37499	10041-10002-00553	6040 W SUNSET BLVD 5th Floor	90028		147A189    54	5545013402	M1-1		Hollywood	Hollywood Studio District			Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM			PC Info Complete	08/16/2010 12:00:00 AM	ADDRESS	34.0978	-118.32068	Supplemental changes from previously approved plans.  Changes  include general lighting in room #05-019, lighting automatic control in room #05-045 and -047, removing all floor receptacles, and add fire smoke damper in elevator lobby.  All changes indicate by DELTA 3 as shown on plans.  Plan check for power and energy.******Revisions of permitted set of plans :  in the pantry relocated luminaires in order to make revisions to nearby DDCbay room; moved walls to expand the areas of enclosed office. all changes are bubbled.on the plans .  Core and shell under #06041-10000-02712*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37500	13041-10001-23654	11150 W SANTA MONICA BLVD 2nd floor	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.04704	-118.44563	2253 sq ft office TI on 2nd floor of highrise building.  Newly connected load less than 400A, plan check only for Title 24 compliance.  emergency fixtures fed via (E) emergency ckts. Permit to be issued by electrical plan check counter.note: permit fee calculated under inspection fee category	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37501	10041-10000-16873	1313 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.05055	-118.2249	Solar voltaic system installed on the roof of the building.  Consists of  12 modules,  12  A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37502	18041-20000-38592	1743 S BUTLER AVE 1-8	90025	11	126B149   479	4261015018	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Apartment			10/09/2018 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.04255	-118.44953	service upgrade 600 amps.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37503	16041-20000-39806	21911 W DEVONSHIRE ST	91311	12	204B101   149	2722018025	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.25741	-118.60541	change of use from retail to vet clinic.  ti to an existing commercial building.  adding new lighitng new controls to exisating panels.  plan check for energy and em lighitng.  total square footage 889.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37504	12041-20001-14428	9018 N WOODMAN AVE	91331	6	195B153   179	2642031018	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	34.23362	-118.4389	LOST ORIGNAL SET OF PLANS. RESUBMITTAL.T.I. to an existing building in dining and restroom.  Install general/emergency lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37505	11041-10002-21412	250 S HARBOR BLVD RstRm-3 of 3	90731	15	018B201   623	7440030***	M2-1, [Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			PC Info Complete	06/14/2012 12:00:00 AM	ADDRESS	33.74182	-118.27938	Restroom Building 3 of 3.  <<<<<<SITE DEVELOPMENT FOR USS IOWA BATTLE SHIP PROJECT AT BERTH 87.  SCOPE OF WORK INCLUDES PROVIDING POWER TO THE SHIP AND THE ACCESSORY BUILDINGS AT 34.5KV TO 6.6KV TO 480V TO 208/120V.   (1 OF 3 ).    (RESTROOM BUILDING WAS SUBMITED UNDER 11041-10001-21412) AND (THE TICKET BOOTH BUILDING WAS SUBMITED UNDER 11041-10002-21412).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37506	16041-20000-44209	330 N FAIRFAX AVE	90036	5	138B177   271	5527037041	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	03/29/2021 12:00:00 AM	ADDRESS	34.077	-118.36127	Core and shell for new three story office building with new 480Y/277V 1200 amp service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37507	15041-20000-11515	5046 N HASKELL AVE	91436	5	171B141   348	2261032022	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.16249	-118.47468	PV1 SFD. TOTAL SYSTEM SIZE 6.8KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37508	14041-10000-09094	2756 S DUMFRIES ROAD	90064	5	126B161   509	4318016011	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.03858	-118.41471	PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE3000A-US-ZB-U.(10) Modules: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37509	18041-20000-45100	2828 W LONDON ST	90026	13	139-5A203 232	5402008025	C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	Apartment			11/27/2018 12:00:00 AM	01/15/2021 12:00:00 AM		Permit Finaled	11/04/2022 12:00:00 AM	ADDRESS	34.07635	-118.27539	1200A 240/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37510	19041-20000-00071	16223 W NORDHOFF ST	91343	12	198B137  1009	2676015015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.23581	-118.48587	Plan check for a PV1 roof-mounted PV system. System size is 9 kWdc/8 kWac and consists of (25) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37511	17041-20000-44631	4922 N BALBOA BLVD	91316	5	168B145   769	2261039012	C4-1L, C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01, 1414.00	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.15993	-118.50084	EARLY START PERMIT -  INTERIOR NONSTRUCTURAL DEMO. SEE COMMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37512	15041-10000-08260	7910 N CLYBOURN AVE STE B	91352	2	189B177   393	2466031026	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Expired	04/13/2017 12:00:00 AM	ADDRESS	34.21443	-118.36393	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37513	19041-20000-41989	7661 N DENSMORE AVE	91406	6	186B141    18	2206010007	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.21008	-118.47725	PV1. INSTALL 10.4 KW DC / 9.53 KW AC SYSTEM WITH (32) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37514	15041-20000-22794	9131 N OAKDALE AVE #100	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.23697	-118.56716	Plan check for Title 24 only in existing office building. Total indoor area: 10,598sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37515	14041-10000-18345	1925 S CENTURY PARK EAST 4th Floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/08/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SUITE 420. CORRIDORS  AND RESTROOMS. 1344 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37516	15041-10000-30276	555 S FLOWER ST STE 4410	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Issued	09/14/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL Sq. ft. 2225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37517	13041-10000-33278	1111 W WILSHIRE BLVD #103	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.05259	-118.26348	Full plan check for power and energy for a first time tenant. New resturant.EPC is for power and T24.  (new 3 panels and lighting)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37518	14041-10000-35767	111 E UNIVERSAL HOLLYWOOD DR 4TH-7TH-FLOORS	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM			PC Approved	12/29/2014 12:00:00 AM	ADDRESS	34.13855	-118.36112	ALTERATIONS IN OFFICES ON THE 4TH,5TH,6TH,, AND 7TH FLOORSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37519	14041-10000-05686	1432 S VICTORIA AVE	90019	10	129B185  1275	5082023033	R2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.04615	-118.32878	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER. TWO STORY HOUSE. SYSTEM SIZE: 1.5 KW DC.(6) TRINA SOLAR TSM 250(1) POWER ONE AURORA PVI 3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37520	13041-20000-11544	835 W WILSHIRE BLVD 5th Floor	90017	9	130-5A209 194	5144007025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	05/03/2013 12:00:00 AM		Permit Expired	05/28/2015 12:00:00 AM	ADDRESS	34.05005	-118.25891	PC FOR T24 ENERGY ONLY. RELOCATE EXISTING FIXTURES. PER INSPECTOR REQUIST, PC FOR T24. TOTAL AREA 1400 SQ FT. PERMIT WILL BE ISSUED FROM THIS APPLICATION.relocating receptacles and tele/data, LIGHT FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37521	15041-10001-30296	945 S HUDSON AVE	90019	4	132B185   486	5090006009	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	ADDRESS	34.05779	-118.33477	Expedite per applicnt request.((PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.791KW. 33 MODULES AND 2 INVERTERS.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37522	17041-10000-22110	533 W 6TH ST STE R533S	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.04877	-118.25503	Plan check for power and Title 24.  T.I. to existing coffee shop (Starbucks coffee) and expansion into adjacent space.  Lighting area = 2,512 sq. ft.       Building permit 17016-10000-17749	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37523	16041-20000-09531	3667 S MCCLINTOCK AVE	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Expired	08/30/2016 12:00:00 AM	ADDRESS	34.02081	-118.29008	Plan check for power. Work includes the replacement of a medium voltage SF6 ATS with a medium voltage manual transfer switch.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37524	12041-10000-01072	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	33.9451	-118.37436	New Fire alarm system for a highrise Bldg. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37525	19041-20002-47004	19656 W FALCON RIDGE LANE	91326	12	217-5A117 183	2701022028	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.28965	-118.56213	12-20-2019 Changes to an approved set of plan, changes include derate main breaker and keep existing 200A Main Service Panel. Plan check only. Permit shall be pull separately for sub-panel and derate main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37526	19041-10000-05650	13755 W ROSCOE BLVD Unit D	91402	6	192B153   739	2637029012	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM			PC Info Complete	07/31/2020 12:00:00 AM	ADDRESS	34.22182	-118.43315	Full plan check for a restaurant/ icescream parlor ( first time tenant) T.I. Scope includes new light and equipment with a total area of 1,453-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37527	16041-10000-02668	1227 W 38TH ST	90037	8	117B197   449	5037013030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.01743	-118.29833	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(22)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37528	17041-30000-44111	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	33.98095	-118.40764	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 10,924 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37529	18041-20001-12531	5555 W MELROSE AVE Stage 3	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Issued	05/01/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Revisions to approved set of plans.  Change of feeder wiring details, overcurrent protection ratings, and replacement of gutters with (2) new panelboards.  (((Plan check for power service replacement for 1200A  to new equipment and reconfigured location of service equipment. Exinsting load to remain)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37530	17041-20000-20884	1721 W SUNSET BLVD	90026	13	139-5A209  76	5419030010	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.07767	-118.25896	Plan check for energy only. TI to Mexican restaurant. New lighting - indoor 2,481sqft, outdoor 140sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37531	14041-10000-02403	1015 S CROCKER ST #R-21	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	Remove HID light fixtures and replace with new fluorescent fixtures in retail space.  Title 24 plan check for fixture one-to-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37532	18041-10000-29360	12130 W MILLENNIUM 2nd & 3rd-Floors	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.98008	-118.40646	TI IN AN EXISTING OFFICE BUILDING ON THE 2ND AND 3RD FLOORS. AREA: 46790 SQR FT.BLDG PERMIT: 18016-10000-24869	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37533	19041-10000-24753	3901 S VERMONT AVE	90037	8	117B197   844	5037019059	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.01534	-118.2918	Plan check for removing HID fixtures and replace with new LED Fixture for outdoor area with a total lighting fixture of 4330-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37534	13041-10000-24131	11427 S AVALON BLVD	90061	15	087A207   367	6083006015	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	33.93019	-118.2654	FA NEW FA FOR ALLIANCE COLLEGE-READY PUBLIC SCHOOL. 1 facp, 1 annunciator, and 16 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37535	16041-10000-42181	255 W 42ND PL	90037	9	114A203   188	5111017015	R2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.00664	-118.27747	PV, INSTALL NEW 5040W DC/4533.48 W AC ROOF-MOUNTED SOLAR ARRAY ON ASINGLE FAMILY HOUSE.(18) MODULES: HANWA Q-CELL, Q PLUS-G4 280(1) INVERTER: SOLAREDGE S3E3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37536	18041-20001-05959	1814 N WEBSTER AVE	90026	13	145-5A205 296	5431031009	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM			PC Approved	06/28/2018 12:00:00 AM	ADDRESS	34.0922	-118.26919	06-28-2018 Changes to an approved set. Changes include revise load calculation. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37537	16041-20000-08326	2645 W IVANHOE DR	90039	4	150A207   167	5439011010	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.10537	-118.26319	Install a roof-mounted solar array on a SFD. Interconnect witha 200A MSP. Derating main to 150A.System size: 6kW (3+3). Ungrounded system. (29) 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37538	13041-10000-35002	12501 N KENNY DR	91344	12	219B137    63	2609021014	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.29714	-118.49812	PV1, Install 9 kW DC grounded microinverter, roof-mounted solar array, interconnect with service panel.  Inverter. Enphase Energy M215-100-24  S22123. (36) modules SOLAR WORLD Sunmodule SW 250 Poly	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37539	16041-10000-30605	1846 S ROBERTSON BLVD	90035	10	126B169    62	4303006015	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	09/03/2016 12:00:00 AM	ADDRESS	34.04533	-118.3863	PC FOR A NEW FIRE ALARM SYSTEM FOR A DAYCARE CENTER. SCOPE INCLUDES 25 FA DEVICES, AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37540	19041-10000-49525	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	02/21/2020 12:00:00 AM		Permit Finaled	04/11/2020 12:00:00 AM	ADDRESS	34.05949	-118.42045	Energy bplan check only, area of scope (475)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37541	12041-20000-02542	107 S FREMONT PL WEST	90005	4	132B185   237	5090014012	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.05975	-118.3286	Remodel single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37542	16041-10000-42962	433 W LACONIA BLVD	90061	15	081B201   129	6132020047	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.91987	-118.28228	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.6KWdc / 10.0KWac.(40)MODULES-JKM265P(2)INVERTTERS-SOLIS-5K-2G-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37543	18041-10000-09591	16945 W SAN FERNANDO MISSION BLVD	91344	12	210B133   434	2682021030	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	ADDRESS	34.2722	-118.50147	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37544	17041-10000-27388	11451 N SEPULVEDA BLVD	91345	7	213B145   101	2664001021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.27851	-118.46904	REMOVE METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES - T24 ONLY. TOTAL SQUARE FT 23650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37545	15041-20000-07227	9213 N TOBIAS AVE	91402	6	198B149   414	2651008010	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Apartment			03/12/2015 12:00:00 AM			PC Info Complete	06/30/2015 12:00:00 AM	ADDRESS	34.23768	-118.45185	Plan check for power and energy new 21 units appartment 1200A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37546	18041-10000-31739	1211 E PRESTON WAY	90291	11	111B149   355	4244026004	R1-1VLD	West Los Angeles	Venice	Grass Roots Venice	YES	2731.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	12/29/2018 12:00:00 AM	ADDRESS	34.00225	-118.45613	Plan check for a PV1 roofmounted system with a 6KW inverter and (15) modules interconnecting through a new load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37547	11041-20000-04858	2201 S LINCOLN BLVD Preschool	90291	11	108B149   385	4241034027	C2-1, R2-1, [Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	33.99481	-118.45469	Change of use from retail/restuarant to pre-school.  Install new branch circuits, equipment, and lighting.  Existing panels. Plan check for power and energy. Core and shell 800A service approved under #10041-10000-14662	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37548	17041-10000-06247	6600 N TOPANGA CANYON BLVD EV3	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	03/29/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR POWER. PERINSPECTOR REQUEST FOR ADDITION OF LOADS. INSTALLATION OF  9 EV CHARGING STATIONS. PERMIT HAS BEEN ALREADY PULLED UNDER 16041-20000-36524	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37549	11041-20000-23166	8914 W PICO BLVD	90035	5	132B169   900	4305014012	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM			Corrections Issued	10/28/2011 12:00:00 AM	ADDRESS	34.05505	-118.3861	restaurant remodelEnergy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37550	19041-30000-11890	601 S FIGUEROA ST 41st Floor-Restrooms	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to common area restrooms. Total lighting area = 500 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37551	16041-10001-28595	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	Supplemental PC to check revised emergency ligthing circuit. Inspector required applicant to connect emergency circuits to existing building generator. Changes are under delta 8.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37552	16041-10000-10008	312 S ALAMEDA ST	90013	14	127-5A215  66	5163010002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.04494	-118.23784	"New electrical system on (E) build. New 2000MSA, scope includes 400A  House Panels ""HDB"". Restaurant and offices will be submitted under independent TI. Indoor total area: 15,709 sq. ft. Outdoor light for path of egress will only be temporary."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37553	18041-20000-18165	1513 S GRAND AVE Ste 360	90015	14	124-5A207 123	5134015027	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.03622	-118.26632	TI to medical office in (E) commercial building.  Plan check for power and energy. Total area: 2122 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37554	16041-20000-23438	800 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.04484	-118.26453	Plan check Title 24 only. T.I. in existing restaurant Total newly connected load is less than 400A. Total area: 6,456 sq ft. replacing devices - altering location of existing equipment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37555	17041-10000-41850	950 N WESTERN AVE	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			Reviewed by Supervisor	11/29/2017 12:00:00 AM	ADDRESS	33.75127	-118.3088	PC FOR EYE EXAM ROOM IN CVS FOR MEDICAL  POWER B# 17016-20001-07245PERMIT FEES PULLED UNDER 17041-40001-38736	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37556	11041-20000-15026	18001-18137 W CHATSWORTH ST BLDG A	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.26501	-118.52523	PLAN CHECK POWER AND ENERGY FOR VANILLA SHELL RETAIL/RESTAURANT SPACES TO EXISTING SERVICE AND BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37557	17041-10000-25942	454-518 E COMMERCIAL ST	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.05313	-118.23621	POWER PLAN CHECK ONLY FOR CNG FACILITY. INSTALLING DISTRIBUTION FOR MAIN COMPRESSORS, AND GAS DISPENSERS. NEW 1200A MCC AND RELATED LOADS. CANOPY LIGHTS AND OTHER LIGHTINGS ARE NOT PART OF THIS SCOPE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37558	11041-10000-03550	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	2951.01	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	ADDRESS	33.77884	-118.29327	installation of  MV feeder/pump motor ; feeder originates from 4160V SWITCHGEAR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37559	17041-20000-24657	1356 S ALBANY ST	90015	1	127-5A203 394	5135035014	CM-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.04184	-118.27479	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37560	17041-10000-04748	1612 S BURLINGTON AVE	90006	1	127-5A201 386	5135017012	M1-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Issued	02/14/2017 12:00:00 AM	ADDRESS	34.04184	-118.28104	CHECKING T24 FOR NEW BATHROOM LIGHTING. TI TO AUTO REPAIR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37561	15041-20000-11422	17732 W MELVIN LANE	91325	12	195B129   337	2768012038	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.23045	-118.52155	upgrade 600a to 800 A for solar	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37562	13041-10000-13953	5711 W CENTURY BLVD	90045	11	093B169   327	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	33.94573	-118.38128	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT FOR EXISTING JR. BALLROOM. PLACE OF ASSEMBLY MORE THAN 100 OCCUPANTS. GROUND FLOOR HILTON HOTEL. VARIANCE ON FILE FOR CUSTOM PENDANT FIXTURE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37563	17041-10000-36501	7080 W HOLLYWOOD BLVD STE 318	90028	13	147B181   231	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.10134	-118.34445	"Plan check for classrooms TI for title 24 energy only. total effect of the area 3465 s/fscope includes kew lights and receptacles B# 17016-10000-23920Change of use and T.I. for irregular shape 87'-5"" x 58'-1"" portion of existing Medical Office to new Adult Language Tutoring Center.*********SEE COMMENTS**********"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37564	19041-20000-36596	22110 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.1863	-118.60874	Plan check for PV roof mounted system, system size: 19.14KW DC, 16.9KW AC CEC with 44 PV Modules and 2 inverters(9KW)Note: 12 Buildings in 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37565	11041-10000-19965	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	Title 24 and emergency lighting for a low rise retail center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37566	13041-20000-09108	13402 W WYANDOTTE ST	91605	2	186B157   616	2328026055	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.20247	-118.42524	energy plan check studio	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37567	14041-20000-03110	5716 N BUCKNELL AVE	91607	2	174B169   505	2339006023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.17437	-118.3901	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37568	06041-10002-30309	802 S PIER A ST BERTH 155	90744										Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			PC Approved	07/25/2011 12:00:00 AM	ADDRESS	33.75729	-118.27049	Remodel a portion of the warehouse at PORT OF LOS ANGELES, Berth 155.  Power and energy.  <<<<<<<<RESUBMITTAL FOR EXPIRED PLAN CHECK>>>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37569	15041-10000-23436	1068 S POINT VIEW ST	90035	5	132B173   772	5087024023	R1-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Expired	10/06/2017 12:00:00 AM	ADDRESS	34.05667	-118.36777	PV1 7KW AC ROOF MOUNTED SYSTEM WITH (28) LG-LG300S1C MODULES AND ENPHASE M-250 MICROINVERTERS INTERCONNECTING THROUGH THE MAIN SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37570	14041-20000-18826	7250 N WOODVALE CT	91307	12	186B093   694	2027006***	(Q)RD6-1, RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.20177	-118.63318	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.1KW AC USING MICROINVERTER. ENPHASE M215. USING STANDARD PLAN. ROOFTOP MOUNTED PV	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37571	14041-20001-35629	13051 N MEADOWLARK AVE	91344	12	222B133   178	2601019031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2014 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.30623	-118.51005	Fee for expedite only.*****Roof mounted PV system with total system size 6.5KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37572	19041-10000-37397	1840 W YOSEMITE DR	90041	14	159A223     5	5685020900	OS-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.13345	-118.20805	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37573	18041-10000-10007	1389 W 29TH ST	90007	8	120B197   103	5055009029	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.0285	-118.29109	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37574	16041-10000-40624	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	PC FOR DISTRIBUTION SYSTEM. SHELL OUT FUTURE TENANT SPACE. INSTALL NEW 800 BUS TAP FROM EXISTING SERVICES AND NEW 1600A DISTRIBUTION. PC FOR POWER ONLY. SOME NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37575	11041-20001-00711	10250 W SANTA MONICA BLVD #616	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM			PC Approved	03/21/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	Revision to approved plan. Revision to remove feeder to new panel and provide conduit only. Panel, feeder, and load will be provided others.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37576	19041-10000-20088	2748 W 8TH ST 202	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.05747	-118.28552	PC (ENERGY ONLY) CHANGE OF USE FROM EXISTING 3,712 SF RETAIL TO CREATIVE OFFICES.  AREA OF SCOPE 3496SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37577	19041-20000-51974	2241 S CLYDE AVE	90016	10	123B177    99	5064023007	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM			PC Info Complete	10/21/2021 12:00:00 AM	ADDRESS	34.03697	-118.36568	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37578	15041-20000-18001	51 E PALOMA AVE	90291	11	109-5A143 172	4286021026	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	33.99432	-118.47785	Installation of new roof mounted solar PV array.  Total area = 6.25 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37579	15041-10000-10952	1900 S AVENUE OF THE STARS 530	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Issued	04/13/2015 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI TO AN EXISTING HIGH RISE BUILDING, ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2170.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37580	17041-10000-35442	261 N ROSEMONT AVE	90026	13	138A205   266	5157012038	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Issued	10/26/2017 12:00:00 AM	ADDRESS	34.07088	-118.27102	Install new rooftop solar on a commercial building. (114) modules with P600 optimizers, (2) 14.4 kW invertersPERMIT FEE IS ZERO DUE TO SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37581	13041-10000-16400	750 S LAMAR ST DRVR HELP-CENTER	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (4.)  DRIVER HELP CENTER. SOME INDOOR LIGHTING, 1 PANEL, AND ITS BRANCH CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37582	16041-20000-11023	5727 W LA MIRADA AVE	90038	13	144B189   118	5536001017	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			04/11/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.09387	-118.31452	New 28 unit apartment building 3 story type V-A over 1 story of subterranean parking type I-A.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37583	15041-20000-21955	7962 W OCEANUS DR	90046	4	153B173   906	5569025024	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.11231	-118.36825	Plan check for PV roof mounted system. System size: 11.0kW with 42 modules and 42 microinveters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37584	10041-20000-16518	10960 W WILSHIRE BLVD 16th floor	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check T-24 Energy general/emergency lighting for office TI on the 7th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37585	10041-10000-08255	10535 W WILSHIRE BLVD 1-215	90024	5	135B153   467	4360018***	[Q]R5-3	West Los Angeles	Westwood			2652.00	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.06293	-118.43312	Replace existing Fire Alarm Panels in the building (Existing Devices).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37586	13041-20001-32720	18758 W WELBY WAY	91335	3	180B121   108	2126036013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.19277	-118.54245	(Expedite fees)PV1 MICROINVERTER PLAN. TOTAL SYSTEM SIZE IS 6.5KW. 26 PANELS AND MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37587	13041-10000-26579	807 S MATEO ST	90021	14	124-5A217 354	5166017016	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.03334	-118.23241	TITLE-24,PART 6 LIGHTING PLAN CHECK. SCOPE OF WORK IS FOR REMOVING 400W HID LIGHT FIXTURES AND INSTALLING NEW FLOURENSCENT FIXTURES IN AN 5525 SQ FT. AREA. ALTERATIONS IS FOR REPLACEMENT OF NEW FIXTURES, NO NEW OR MOVED WIRING IS BEING INSTALLED TO SERVE ADDED OR MOVED LUMINAIRES. EXEMPT FROM 131(A) AREA CONTROLS REQUIRING VISIBILITY OF THE CONTROLLED AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37588	13041-10000-10786	155 S LAYTON DR	90049	11	135B145   327	4365004032	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02, 2654.10	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.06769	-118.46857	PV2 PLAN CHECK FOR NEW 8.6KW PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS. BRENTWOOD PRIVATE HIGH SCHOOL. MODULES INSTALLED ON ROOF OF TRELLIS AND GUARD SHACK LOCATED IN LA COUNTY JURISDICTION. PV INTERCONNECTION AT BUILDING LOCATED IN CITY OF LA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37589	18041-20000-22095	280 N CAROLWOOD DR	90077	5	141B157    50	4358006012	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.08319	-118.42757	Installation of 125 kW optional standby generator - backing up entirety of SFD load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37590	18041-10000-21704	9022 S VERMONT AVE	90044	8	094-5A199  72	6038019029	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Issued	06/12/2018 12:00:00 AM	ADDRESS	33.9544	-118.29136	PLAN CHECK FOR TITLE 24 ONLY TO REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37591	13041-20001-00114	13833 W VENTURA BLVD # 105	91423	4	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM			PC Approved	01/14/2013 12:00:00 AM	ADDRESS	34.1487	-118.43426	Changes to approved set of plans. Plan check for energy only. 602sqft. Suite #105T-24 lighting plan check for new beauty salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37592	16041-10000-17803	633 W 5TH ST 1ST FLOOR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	T-24, PC FOR ENERGY ONLY TO AN (E) RESTAURANT IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1890.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37593	14041-20001-11429	6615 N ALLOTT AVE	91401	2	180B157   403	2329009038	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/14/2014 12:00:00 AM	ADDRESS	34.19075	-118.42822	Expedited plan check per applicant request.  PV1.  Install 11.00 kW roof-mounted PV system, interconnect with main service panel.  (44) modules.  (2) transformerless inverters: SolarEdge SE5000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37594	14041-10000-32459	4121 W AVENUE 41	90065	14	157-5A217 200	5473001022	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.12597	-118.2299	PV 1 Roof mounted  System size: 6kW with 34 modules(KYOCERA KD 200-60 F Series) and 2 inverters (ABB String invetersPVI 3.0-OUTD-S-US-Z-A)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37595	13041-10000-06625	9301 N TAMPA AVE 114	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	06/04/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	T24 PC FOR LIGHTING IN RETAIL SPACE. TOTAL AREA 1600SQ FT. ENERGY ONLY. PERMIT TO BE ISSUED FROM PC STAFF ONLY. WORK DONE IS TENANT 114. THINGS REMEMBERED RETAIL SPOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37596	19041-10000-28284	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	33.98076	-118.40716	PC FOR METHANE GAS DETECTION SYSTEM(LEVEL 1). SCOPE INCLUDES ADDING 7 METHANE SENSORS TO AN EXISTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37597	13041-10001-27007	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.0484	-118.26248	(((4/25/2014: RELOCATING BIKE RAKE ENCLOSURE. ENERGY CALCULATIONS TO BE VERIFIED. THIS IS A PLAN CHECK ONLY APPLICATION)))pc for power and energy. 1200A SERVICE. New 6-tier parking structure with offices on the 6th floor.  NOT methane. fire sprinkler throughout? B occupancy as seen on 13010-10000-02439	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37598	13041-10001-24714	14722 W MAGNOLIA BLVD UNIT 2	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37599	12041-10000-28492	18433 W ROSCOE BLVD	91325	12	192B125   578	2786022035	QC1-1VL, QP-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			11/28/2012 12:00:00 AM			PC Approved	11/28/2012 12:00:00 AM	ADDRESS	34.22091	-118.53469	TI FOR EXISTING PHARMACY. 4 STORY. 1584SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37600	19041-20000-00974	13444 W VAN NUYS BLVD	91331	7	207B157   781	2620010024	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Info Complete	01/09/2019 12:00:00 AM	ADDRESS	34.26312	-118.42587	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 565 sq. ft.Note: Building application has been generated under 17016-20000-02436	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37601	12041-10000-30870	4801-4803 W ADAMS BLVD	90016	10	123B181   955	5057002005	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			12/24/2012 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	10/12/2023 12:00:00 AM	ADDRESS	34.03269	-118.34516	MIXED USE: NEW 6 UNIT APARTMENT BUILDING, LOW INCOME HOUSING W/ GROUND LEVEL RETAIL AND ACCESSORY OFFICE USE.  3 STORY STRUCTURE WITH USUABLE ROOF DECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37602	15041-20000-24966	20301 W VIA SANSOVINO	91326	12	219B113   270	2701061010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Expired	09/05/2017 12:00:00 AM	ADDRESS	34.2969	-118.57556	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(27) Kyocera KU2656 Modules(1) Solaredge SE 6000A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37603	13041-10000-35009	11500 N AMIGO AVE	91326	12	213B121   380	2871010021	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.28054	-118.54171	PV1.  Install 9.7 kW AC roof-mounted PV system, interconnect with main service panel.  45 modules: Solar World SunModule SW250Poly.  Microinverters: Enphase M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37604	10041-10000-24358	760 N LA CIENEGA BLVD 3rd floor	90069	5	141B173   232	5528001060	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM			No Progress	06/30/2011 12:00:00 AM	ADDRESS	34.08513	-118.37632	T-24 lighting plan check for a portion of a salon.  See existing permit 10041-40000-23335 for inspeciton.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37605	16041-10006-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	05/10/2021 12:00:00 AM	ADDRESS	34.04771	-118.46271	PC for changes to approved set for cedars sinai. Changing lighting and power due to room layout changes. Installing new 600A distribution board for new MRI and CT equipment. All changes are for 2nd floor. Changes clouded under delta 16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37606	12041-20000-13751	5450 S LINCOLN BLVD	90094	11	102B157   293	4211022004	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	33.97348	-118.43093	Change from office to medical building.  Install new subpanes, emergency generator, and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37607	18041-10000-49207	2721 E 11TH ST	90023	14	120A221    81	5170027004	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.02312	-118.21926	Energy plan check for an office T.I. Scope includes new lighting and equipment with a total area of 10,282-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37608	14041-20000-27791	1495 S ROXBURY DR	90035	5	129B165   298	4307003006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.05205	-118.40172	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3KW INTERCONNECTED WITH MSP.(20) SUN MODULES SW 250(20) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37609	13041-10000-00413	470 E 3RD ST	90013	9	129A215   263	5147004017	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.04621	-118.24052	CHANGE OF USE FROM OFFICE/RETAIL TO MEDICAL OFFICEIN AN EXISTING 3-STORIES BUILDING; THE SERVICES WILL REMAIN, BUT THE PANELBOARDS WILL BE REPLACED, NEW CIRCUITS AND NEW HVAC SYSTEM. LESS THAN 400A  ADDED;FLOORS ARE MIRROR IMAGES OF EACH OTHER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37610	16041-20000-45097	1701 S LA CIENEGA BLVD	90035	5	129B173  1254	4303027042	C2-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.04701	-118.37637	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from auto repair to nursery school/tenant improvement. Total lighting area = 8,765 sq. ft.Note: Building application has been generated under 16016-10000-30600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37611	17041-10000-12657	12458 N GLADSTONE AVE	91342	7	219B161   197	2525019058	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.29612	-118.41197	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 71,500 SQFT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37612	15041-10000-09132	3315 N VERDUGO ROAD	90065	1	153A215   307	5457022028	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.11215	-118.23612	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3100 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37613	12041-20000-05949	21480 W VICTORY BLVD	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	ADDRESS	34.18797	-118.59864	energy plan check retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37614	15041-10000-04401	14646 W KESWICK ST	91405	6	186B149    39	2210029017	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.21016	-118.45257	Title 24 plan check only.  Total area = 4,232 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37615	13041-20000-00994	4644 N HAYVENHURST AVE	91436	5	168B137   604	2284002042	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2013 12:00:00 AM	01/15/2013 12:00:00 AM		Issued	01/15/2013 12:00:00 AM	ADDRESS	34.15456	-118.4916	PV-1. Microinverter standard plan. 7.3 kW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37616	16041-20000-21776	14520 W MAGNOLIA BLVD	91403	4	171A151    56	2263034018	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			06/21/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.16469	-118.44951	Plan check for PV roof mounted system. System size: 14kW with 60 modules and 2 inverters(7.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37617	11041-20000-14118	10635 W SANTA MONICA BLVD	90024	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM			PC Info Complete	07/07/2011 12:00:00 AM	PIN	34.05365874	-118.43036269	Ti in an existing office BLDG. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37618	16041-10000-30891	2122 S CENTURY PARK LANE	90067	5	132B161    75	4329009***	R4-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Apartment			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	01/14/2017 12:00:00 AM	ADDRESS	34.05709	-118.41284	PC FOR AN EXISTING FIRE ALARM SYSTEM SCOPE INCLUDES REPLACING THE FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37619	19041-20000-47089	11601 W WILSHIRE BLVD STE 1960	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	Tenant improvement add new lights plan check for title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37620	19041-10000-26375	6101 W 96TH ST ITF-West	90045	11	093B169   346	4124020***	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	09/27/2022 12:00:00 AM	ADDRESS	33.94901	-118.39043	LAX,  ITF-West parking structure and provisions for the security badging office (SBO)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37621	16041-10000-43324	1400 N GAFFEY ST	90731	15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	33.75723	-118.29183	Plan for Title 24 only in existing private road for Los Angeles Sanitation. Total area: 34,248 sq ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37622	19041-20000-20206	4827 N HERMANO DR pv1	91356	3	168B125   262	2176016013	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.1583	-118.53704	pv1install  roof mounted pv system sized 13.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37623	14041-20000-29207	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	Service upgrade to 1200A, 4160 volts, 3 phase, 3 wire.  Install new service equipment and feeders and outdoor lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37624	11041-20000-08507	22500 W JEFFREY MARK CT	91311	12	204B097    15	2724004***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			04/27/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.25628	-118.61737	Plan check 4.8KW Photovoltaic System for condo building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37625	19041-20000-53269	19710 W SEPTO ST	91311	12	201B117    48	2726004014	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.25083	-118.5627	Plan check for PV roof mounted system, PV system size: 10.54KW DC, 9.761KW AC CEC  with 31 PV Modules and 1 inverter(10KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37626	17041-20000-16001	3833-3835 S KEYSTONE AVE 1-5	90232	5	117B165   244	4208009027	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.01838	-118.40555	PV2.  Install 1.45 kW AC roof mounted grid tied PV system.  (5) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37627	13041-20000-21247	19925 W LANARK ST	91306	3	189B113    56	2106031021	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	09/03/2013 12:00:00 AM	ADDRESS	34.21812	-118.56754	((APPLICATION IN ERROR. TOTAL 27 MODULES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING SINGLE TRANSFORMERLESS INVERTER. 2 STRINGS. NONSTANDARD PLAN TOTAL OF 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37628	17041-20001-41920	6111 S GRAMERCY PL	90047	8	105B189   843	6001012028	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	33.98411	-118.31358	03/30/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made throughout the plan set to reflect field conditions.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.  T. I. TO (E) 2ND FLR SPACEBUILDING PERMIT # 17016-20000-34392	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37629	15041-20000-15150	10920 N WINNETKA AVE	91311	12	210B113   156	2708021007	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.26855	-118.56904	Plan check for a PV1 ground-mounted PV system. System size is 21 kWac and consists of (3) inverters, (66) modules, and (1) subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37630	18041-10000-21503	6200 W HOLLYWOOD BLVD	90028	13	148-5A189 354	5546028***	[T][Q]C4-2D, [T][Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.10136	-118.32459	"PC FOR POWER AND ENERGY FOR A FIRST TIME TENANT ""LITTLE RADISH"" RESTAURANT. SCOPE INCLUDES NEW DISTRIBUITION, PANELS, EQUIMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA  1516 SQ.FT B#18016-10000-03752ELECTRICAL CORE AND SHELL UNDER #"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37631	11041-10000-19415	1511 W FRANCISCO ST Bldgs A&B	90501	15	057B193   154	7351021045	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Public Safety Only			09/13/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	33.85075	-118.30473	INSTALLATION OF SPRINKLER MONITORING SYSTEM WITH CENTRAL STATIONFACP IS LOCATE DIN BUILDING  A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37632	18041-20000-40862	5062 N ORRVILLE AVE	91367	3	171B089   299	2047012021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.16274	-118.64472	pv1install roof mounted pv system sized 15.2KW AC interconnected with msp.  (53) solarworld 295W modules(2) solaredge 7600W inverters	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37633	13041-10000-32493	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.94502	-118.40714	TENANT IMPROVEMENT- RELOCATING US AIRWAYS OFFICES FROM TERMINAL 1 TO TERMINAL 3THIS INCLUDES 3 FLLORS;TITLE 24 APPROVAL WAS OBTAINED ON 13041-10000-20195;13041-10001-20195; 13041-10002-20195 FOR THE THREE FLOORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37634	19041-20000-27709	4335 W CEDARHURST CIR	90027	4	150B201    80	5591007007	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.11121	-118.28435	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of a battery back-up unit to an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37635	10041-20000-19401	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM			PC Approved	09/29/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	energy plan check suite # 910 existing permit on line	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37636	13041-10000-34519	4545 W RUSSELL AVE	90027	4	150B197   950	5590016025	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.10463	-118.28903	PV1, Install a 5.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE6000A-US] and (23) modules[TRINA SOLAR # TSM-250PA05.18] on a 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37637	10041-20000-24853	14712 W PARTHENIA ST	91402	7	195B149   631	2653016054	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.02	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Closed	03/23/2011 12:00:00 AM	ADDRESS	34.22799	-118.45422	T.I. to existing building of Pizza place.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37638	19041-20000-16692	22135 W ROSCOE BLVD LOT #5	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	12/01/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PV1.  Install 2.1 kW roof mounted grid tied PV system.  (7) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37639	13041-20000-36071	10121 N RUFFNER AVE	91343	12	204B137   659	2685023010	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.25467	-118.49703	PV1 STANDARD PLAN. TOTAL SYSTEM SIZE 9KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37640	12041-10003-29254	380 WORLD WAY Suite-6C4-10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 12041-10000-29254. THE FIRST TENANT LOUNGE TO BE BUILT IN CORE AND SHELL OF LAX. TOM BRADLEY INTERNATIONAL AIRPORT. CHANGES ARE CLOUDED.************************************************************6TH FLOOR FULL TENANT IMPROVEMENT FOR AIRLINE LOUNGE. BUILD-OUT WITHIN LAX CORE AND SHELL. EQUIPMENT INCLUDES TWO MOTORS AND TWO TRANSFORMERS. TITLE 24 AND EMERGENCY LIGHTING ( LTG FORMS WERE NOT SUBMITTED AS PART OF THE PLANS,  AND NO PHOTOMETRICS WERE PROVIDED). THE SERVICE IS EXISTING. ADDRESS LOCATED IN METHANE ZONE. BUILDING APPLICATION NUMBER IS: 12041-10000-23893	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37641	16041-10000-30049	400 WORLD WAY T4 #4B	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	Plan check for exiting food court T.I. at LAX Terminal 4 unit 4B. Total lighting area: 3,503  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37642	13041-10003-35964	1361 W 190TH ST STE 120	90248	15	060B193   382	7351001020	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	33.85852	-118.3026	Modification to approved set of plans (delta-5 revisions).  Addition of new distribution board feeding existing panels and loads to existing tenant space.Sheets affected: E-1.3, E-4((((T.I. to existing Autozone store.  New 800A service, panels, branch circuits, and lighting.  Plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37643	19041-10000-50179	10539 W LE CONTE AVE	90024	5	135B153   165	4360020019	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.06731	-118.43454	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 32 (LG350N1C-V5) MODULES, 32 (ENPHASE IQ7) MICROINVERTERS, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 11.90KW DC & 9.28KW AC.Fees $88.56 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37644	18041-20000-30057	555 S FLOWER ST 40TH-41ST Floor	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for Title 24 only in existing high-rise building partial office T.I. on 40th and 41st Floor  Total area: 13157 sq ftB#18016-100000-08842 and  18016-100000-08848	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37645	17041-10000-07995	6765 W SELMA AVE	90028	13	148-5A185 251	5547013016	C4-2	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Closed	08/14/2020 12:00:00 AM	ADDRESS	34.09981	-118.33796	PC FOR POWER ONLY. TEMPORARY POWER FOR A CONSTRUCTION SITE. SCOPE INCLUDES ADDING NEW 600A 480/277V 3 PHASE 4 WIRE SERVICE, NEW PANELS, AND NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37646	14041-20001-08977	20481 W CELTIC ST	91311	12	210B109    58	2707030001	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.27142	-118.57945	((((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS. 2 CENTRAL INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37647	18041-30000-42853	11601 W WILSHIRE BLVD 24TH FLR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR T-24  ENERGY ONLY FOR RESTOOM AND CORRIDOR TI IN A HIGH RISE BUILDIND ON THE 24TH FLOOR. TOTAL AFFECTED AREA 1684 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLESB#18016-10000-31077	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37648	16041-10000-24546	849 E 6TH ST	90021	14	126A213   228	5147016001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM			PC Info Complete	08/15/2016 12:00:00 AM	ADDRESS	34.04003	-118.24136	Addition and interior change of occupancy to (E) community center operated by private agency.  Install new lights and receptacles. Additional loads < 400A, PC for T-24 only. Total affected area: 3,150 sq.ftB# 16016-20000-13888	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37649	16041-10000-20287	12725 W BLUFF CREEK DR	90094	11	102B161  1273	4211037210	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	33.97499	-118.4153	Install New FA, 1 FA panel, 1 Comm. Panel, 75 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37650	18041-10000-38760	8418 S SAN PEDRO ST	90003	9	097-5A205 145	6030024030	R3-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2398.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	33.96224	-118.26933	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37651	19041-10000-02245	767 S ALAMEDA ST suite200	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Info Complete	01/18/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	PC FOR T-24 ONLY CHANGE OF USE TO OFFICE. AREA 8110SQFTBULDING PERMIT: 18016-10000-39891	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37652	13041-10000-09575	5453 W HOLLYWOOD BLVD SUITE D	90027	13	148-5A193 342	5544007***	C4-1VL, R3-1, [Q]C4-2D	Central	Hollywood	Greater Griffith Park		1904.02	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			Verifications in Progress	05/22/2013 12:00:00 AM	ADDRESS	34.10193	-118.30871	T24 energy plan check for a Starbucks remodel.  2052 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37653	18041-10000-05064	9950 S LAUREL ST SHOPS 2	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	33.94683	-118.23088	"PC FOR POWER ONLY, NEW (1) ONE STORY RETAIL ""SHELL"" BUILDING-SHOPS 2, CONSIST OF 4 FUTURE RETAIL SPACE. SCOPE OF WORK INCLUDES NEW 1600 A, 120/208 V SERVICE AND PANEL BOARDS FOR FUTURE TENANTS. POWER TO SITE LIGHTING AND ELECTRICAL VEHICLE CHARGING STATION ARE PEROVIDED THROUGH SHOPS-2 ELECTRICAL SERVICE.  HOWEVER; LIGHTING LOAD, T-24 CALCS IS UNDER A SEPARATE SET OF PLAN (APPLICATION# E18LA00608). (JORDAN DOWNS PHASE 1C)"	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
37654	19041-30000-39552	401 S BURNSIDE AVE Tower 39	90036	4	135B181   326	5509005009	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	03/22/2021 12:00:00 AM		Issued	03/22/2021 12:00:00 AM	ADDRESS	34.06692	-118.35217	Plan check for power only. Project site is an existing 13-story, 153-unit apartment building. Project scope is a service upgrade to 4,000 Amps. Work includes new service and distribution equipment. Existing tenant panels will be re-fed. This scope of work does not include any new loads within units or house panel. Indicated house and unit loads will be for future scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37655	19041-10000-13682	9348 N FARRALONE AVE	91311	12	198B101   203	2727019043	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.24054	-118.61015	$0.00 fee due to senate bill 1222, and LB1414[e-plan] PV1.  Plan check for a roof mounted PV solar system.  Scope includes 48 modules (Q.peak 295W), 48 optimizers (SE p400)  and  1 inverter(SE11400h-US). System size 14.160 KWdc and 11.4KWac Note: Main Panel Upgrade to 225A shall be Permitted under EXPRESS PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37656	12041-10000-04871	10401 S AVALON BLVD	90003	8	090A207    80	6063020029	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00, 2408.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	33.94176	-118.26534	"T. I. - MIXED A3/R3 OCCUPANCY. OCC. R3 FOR PLACE OF WORSHIP.(REINFORCE FLOOR FRAME; ADD NEW FOUNDATIONS & SEISMIC SHEAR WALLS, NEW DRYWALL, NONBEARING WALLS TO CREATE NEW HC MEN & WOMEN RESTOOMS; REMODEL LUNCH AREA FOR CHURCH. ""COMPLY WITH DEPARTMENT ORDER effective date08/05/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"")"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37657	19041-10000-20040	731 N FAIRFAX AVE	90036	5	141B177   410	5527012006	C2-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			05/28/2019 12:00:00 AM	09/21/2021 12:00:00 AM		Permit Finaled	02/09/2024 12:00:00 AM	PIN	34.08474652	-118.36182228	FULL PLAN CHECK FOR A NEW 1200A (120/208 3P, 4W) THAT FEEDS A 400 DISTRIBUTION BOARDS THAT SERVES ALL ASSOCIATED HOUSE LOADS. THE NEW SERVICE ALSO FEEDS A NEW 700A MULTI-METERING BOARDS THAT FEED VARIOUS SUBPANELS. TOTAL AFFECTED ARERA IS 20,000 SQFT B# 19010-30000-02048	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37658	19041-10000-53451	3619 W OLYMPIC BLVD	90019	4	129B189   138	5092018001	C2-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	34.05307	-118.31813	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY.INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37659	12041-10000-16492	3263 S EARLMAR DR	90064	5	123B161   565	4316008014	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	34.03355	-118.40734	Plan check roof mounted 5.28KW Photovoltaic system (SolarEdge transformer less inverter using DC-DC power box optimizer). Misc permit for power box installation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37660	17041-20001-26340	6300 W SANTA MONICA BLVD	90038	13	144B185   768	5533017019	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.09052	-118.32692	05-15-2018 Changes to an approved set of plans. All changes has been clouded under delta 5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37661	18041-10002-11737	200 N ROCKINGHAM AVE	90049	11	132B137   293	4406008006	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.05882	-118.49112	Change to approved set by reducing the system size to 21.75KW AC with a total of (75) modules and microinverters.(((**Zero permit fee per CA Senate Bill 1222**PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 36KWdc / 28KWac.(100)MODULES-LG LG360Q1C-A5(100)MICROINVERTERS-IQPLUS-72-X-US )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37662	13041-10001-30828	16038 W LONDELIUS ST	91343	12	195B141   648	2672026019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.22926	-118.48187	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 8.75 KW.(35) TRINA SOLAR # TSM-250PA05.18(35) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3800A-US(1) SOLAREDGE # SE5000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37663	18041-10000-29669	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR TITLE 24 ONLY  FOR NEW INDOOR SIGN FOR STORE FRONT (MAC COSMETICS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37664	17041-20000-29728	11765 W LAURELCREST DR	91604	2	162B169  1055	2377003021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.13684	-118.38909	Install 13.5 kWh battery backup system for SFD.  (E) PV system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37665	17041-20001-24964	6810 N SIMPSON AVE	91605	2	183B169   606	2321018011	RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Apartment			09/08/2017 12:00:00 AM			PC Approved	09/08/2017 12:00:00 AM	ADDRESS	34.19433	-118.3888	09/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the outdoor lighting and have been reflected onto the Title 24 forms.*****Previous Work Description*****Plan check for energy only. New 3-story 4-unit apartment w/400A service. Plan check outdoor lighting compliance only (>7 parking spaces) - 3,150sqft. Building plan check application #15010-20000-01949.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37666	17041-10000-32554	7256 N SEPULVEDA BLVD	91405	6	186B145   787	2221018020	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.20287	-118.466	Remove HID fixtures and replace with new LED fixture  - Title 24 only. Total affected area 3500sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37667	16041-20000-18200	5855 S VERMONT AVE	90044	9	108B197  1631	6003005012	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	33.98799	-118.29168	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR TMOBILE STORE. 923 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37668	16041-10000-03878	353 S BROADWAY	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM			PC Info Complete	02/03/2016 12:00:00 AM	ADDRESS	34.04991	-118.24934	PC FOR ENERGY ONLY. T.I OFFICE THAT JUST INCLUDE 5TH FLOOR AND BASEMENT. TOTAL AREA 2390 SQ FT.NOTE: PC ONLY, INSPECTION FEES WERE PAID UNDER EXPRESS # 16041-10000-03831	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37669	14041-10001-33763	12516 W OSPREY LANE 1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	33.97884	-118.41153	Modifications to approved set.  Minor revisions related to relocation of few devices, some omissions, etc. made per inspection comments.  (((Install (N) fire alarm system with (50) notfiication and initiating devices for multifamily dwelling.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37670	19041-10000-03461	6600 N TOPANGA CANYON BLVD #47	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for T24 only Tenant Improvement to (E) retail #47.  Total area approx: 1486 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37671	16041-10000-32555	6171 W CENTURY BLVD	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	33.9457	-118.39324	PC FOR ENERGY. TI. CHANGE OF RETAIL TO RESTURANT. TOTAL AREA 1585 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37672	17041-10001-13115	2716 W OLYMPIC BLVD 108-109	90006	10	129B197   223	5078010028	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.05243	-118.29218	PC FOR TITLE -24 ENERGY ONLY FOR A COFFEE SHOP. PLAN CHECK ONLY PERMIT FEES UNDER MASTER APPLICATION. Total affected area 1080 sq.ftB# 17016-10000-03994	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37673	12041-20000-15204	13400 W WASHINGTON BLVD	90292	11	108B153  1318	4230003077	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM			PC Approved	06/29/2012 12:00:00 AM	ADDRESS	33.99158	-118.44484	T.I. to existing space (suite 111).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37674	14041-20000-15987	14931 W OXNARD ST	91411	6	177A149   104	2242027011	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.17954	-118.45861	ADDITION OF EXISTING VET CLINIC. PLAN CHECK FOR T24 ENERGY ONLY. NO PLAN CHECK PER ARTICLE 517, THIS IS ANIMAL CLINIC ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37675	19041-10000-40590	16722 W PINERIDGE DR	91344	12	219B137   159	2609012022	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	34.29339	-118.49651	[E-PLAN]. PV1. New Roof-mounted solar system consist of 38 modules( SUNPOWER 320) with 38 microinverters(ENPHASE IQ 7X). System size is  12.160KWdc and 11.97KWacPanel Upgrade to be permitted separately	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37676	12041-20000-24559	418 E EDGEWARE ROAD	90026	1	136-5A209 348	5160020051	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Apartment			10/15/2012 12:00:00 AM			Reviewed by Supervisor	11/08/2012 12:00:00 AM	PIN	34.06631622	-118.2546943	192 enphase solar system installtion on the roofs of 4 separate apartment structures.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37677	16041-10005-42999	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Issued	07/08/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	Change to an approved set by modifying the lighting and power on the floor plan. New ckts and panels added. load calculation is being updated with new load , and single line also being modified. All changes under bulletin 1 to 21.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37678	15041-20000-03904	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Info Complete	02/09/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	ADDITION OF TRANSFORMER, PANELS, AND CIRCUITS TO EXISTING MSB.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37679	16041-10000-22285	4001 W VENICE BLVD	90019	10	126B189   214	5072009005	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.04373	-118.32482	NEW SCHOOL - PC FOR POWER AND ENERGY. NEW SERVICE AND DISTRIBUTION. FULL BUILD OUT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37680	11041-20000-13007	600 W 7TH ST STE 160	90017	9	129A209   150	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.04728	-118.25685	CHANG OF USE 1406 SQ FT PORTION OF EXIST OFFICE SUITE 160  TO A TAKE OUT RESTAURANT. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37681	15041-10001-06594	888 S OLIVE ST	90014	14	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	(((4/10/2015- Supplemental to Mehdi's previous approved set that did not include emergency lighting, egress, circuits etc...)))))NEW 33 STORIES HIGH-RISE MIXED USE BUILDING ( COMMERCIAL AND 283 UNITS ) OVER PRIVATE PARKING GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37682	16041-20000-41555	12842 W VENTURA BLVD	91604	2	165B161  1046	2384008027	(Q)P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.14484	-118.4131	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 46,672 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37683	15041-10000-20226	639 N BROADWAY Unit G	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	PIN	34.05985996	-118.23998637	((6/26/2015- RECHECK FOR LOST PLANS. ORIGINAL PLAN CHECK NUMBER 15041-10000-03195)))Energy plan check for a restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37684	11041-10003-23664	808 N NORTH SPRING ST	90012	1	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.06198	-118.23674	CHANGE SIZE OF FIRE PUMP TO from 54 hp to 75 HP. CHANGED SIZE OF CONDUCTOR . OCPD FOR GENSET 400, NOW 350. LOCKED ROTOR WAS CORRECTED. REQUESTED BY INSPECTOR TOM ZACK.Interior work to an existing Shell of an 123 unit apartment building.  Plan check for POWER and ENERGY.  Variance to seperate fire alarm will be filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37685	16041-10005-24899	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM			PC Info Complete	06/13/2017 12:00:00 AM	ADDRESS	33.93576	-118.3779	Changes to approved set.  Plan check for clouded items only.  Reconnect existing dishwasher to main switchboard with new feeders (dishwasher load was previously included in peak demand readings).  Addition of new wall sconce lights and chandelier lighting with updated Title 24 sheets.  Change some fuses to circuit breakers.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37686	17041-10000-20080	523 W 6TH ST 8TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC FOR T24 ENERGY ONLY. PLAN CHECK AND PERMIT FOR LIGHTING UPGRADES IN CORRIDOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37687	14041-20000-26488	160 S JUNE ST	90004	4	138B185   379	5515002007	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.07199	-118.33462	PV1Install roof-mounted solar array on SFD, interconnect with 400A MSP (split service panel, two 200A main breakers). System size: 7.955kW.(37) EnPhase M215-IG microinverters(37) SolarWorld SW270MONO BLK pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37688	19041-20000-16467	11676 W PENDLETON ST	91352	6	195B169   489	2631018047	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	04/24/2021 12:00:00 AM	ADDRESS	34.22813	-118.38704	Plan check for power only service upgrade 1200A 277/480 Volt to the new  manufacturing building. Note: There are 2 applications under 1 plan(19041-20000-16473 & 19041-20000-16467)B#18010-10000-01197	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37689	16041-20000-33645	4130 S GLENCOE AVE	90292	15	108B153  1115	4230006005	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	33.98918	-118.44197	Remove existing hid fixtures and replace with led fixtures outdoors.  plan check for energy only.  total square footage 33608.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37690	15041-20002-19359	9126 N LANGDON AVE 1-15	91343	7	198B145   349	2656026027	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Apartment			11/29/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.23653	-118.46964	11-29-2018 Changes to an approved set of plan, changes include layout configuration electrical equipment in electrical room changes, all changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37691	13041-10001-20833	735 S FIGUEROA ST #133	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	Delta 4 revision to permitted set of plansT.I. REMODEL NON-BEARING INTERIOR PARTITIONS FOR SUITE 133plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37692	19041-10000-16291	818 N HILL ST	90012	1	135A215   289	5408032026	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Issued	08/16/2019 12:00:00 AM	ADDRESS	34.06338	-118.23906	T-24 PLAN CHECK FOR A TI OF AN EXISTING HOTEL. SCOPE INCLUDES NEW  EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 1639 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37693	15041-10000-17218	260 S LA BREA AVE	90036	5	135B181   125	5513023006	C2-1LD, [Q]C2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.06965	-118.34383	Energy plan check for commercial (Ralph's #039) interior T.I. Scope of work is for new storage area;  Electrical inspector verifies Starbucks (prefabircated unit) store to be exempted from plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37694	19041-10000-16948	5174 W WILSHIRE BLVD	90036	4	132B181    32	5507025018	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.06203	-118.34261	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37695	19041-20000-02910	12322 W HESBY ST	91607	2	171B165   966	2356024003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.16215	-118.40179	PV1.  Install 14.04 kW DC / 12.771 kW AC roof mounted grid tied PV system.  (39) modules with microinverters.$31.88 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37696	18041-10001-32413	5628 E KENDALL AVE	90032	14	147A239    41	5309026020	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM			PC Approved	09/06/2018 12:00:00 AM	ADDRESS	34.09851	-118.1574	NEW 12.095 KW (DC) ROOF MOUNTED PV SOLAR SYSTEM WITH 41 PV MODULES ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37697	12041-10000-06375	333 S HOPE ST 19th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM			PC Approved	03/20/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	TI on the 19th floor, title 24 only in a portion of the floor re-arrange light fixture location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37698	19041-10000-27502	21310 W LASSEN ST	91311	12	201B105    82	2746004007	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.24975	-118.59537	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37699	18041-10000-41639	2401 W 6TH ST	90057	1	133-5A203  68	5154038022	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.0611	-118.27802	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37700	14041-20000-13962	20271 W VIA MEDICI	91326	12	219B113   149	2701043021	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Expired	07/15/2016 12:00:00 AM	ADDRESS	34.29451	-118.57542	PV1.  Install 5.865 kW roof-mounted utility-interactive PV system.  Transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37701	15041-20000-07447	4517 N VALDEZ PL	91356	3	165B117    18	2178026011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.15229	-118.55786	Installation of new roof mounted solar PV array.  Total system size = 9.6 kWac.  Two inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37702	19041-20001-11124	5031 N FAIR AVE pv2	91601	2	171B173  1095	2353011037	R4-1	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.1617	-118.37478	expeditepv2install roof mounted pv system sized 166.5KW AC interconnected with msp.(500) astrohalo modules 365Watts(5) solaredge 33.3KW inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37703	18041-10001-33984	7411-8041 WORLD WAY WEST	90045	11	090B157    17	4129026910	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM			Verifications in Progress	04/16/2019 12:00:00 AM	ADDRESS	33.94176	-118.42594	Change to approved set by modifying the load on the single line diagram. monitor load control is being updated, and minor changes also appied to the floor plan. All changes under delta-1 only.(((Power plan check for installing (11) electric bus charging stations.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37704	17041-30000-00332	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	Plan check for T.I. of a coffee shop on first floor of existing highrise hotel building.  Building permit #16016-40000-31167	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37705	15041-20000-33419	20201 W STRATHERN ST	91306	3	189B113   448	2107017115	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Expired	11/03/2017 12:00:00 AM	ADDRESS	34.21571	-118.57306	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (22) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37706	16041-20000-12717	5340 N CORBIN AVE	91356	3	171B117   100	2164019026	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.16783	-118.56254	$0 permit fee is due to State Senate Bill SB 1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37707	15041-10000-04615	100 WORLD WAY TERM 1-APRON LEV	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	TITLE 24 PART 6 REVIEW FOR A TEMPORARY BAGGAGE ANNEX AT  TERMINAL 1  APRON LEVEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37708	17041-20001-31103	511 S LUCERNE BLVD	90020	4	135B189   669	5505020014	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.06483	-118.32462	expeditepv1install roof mounted pv system sized 15.3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37709	14041-20000-04034	6948 N TOBIAS AVE PV1	91405	6	183B149   439	2219024018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Expired	03/09/2016 12:00:00 AM	ADDRESS	34.19702	-118.45187	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH MAIN SERVICE. TRANSFORMER SYSTEM, SIZED @ 6.240 kW DC. (2) INVERTERS, (24) REC 260W MODULES. NEW 200A MAIN PANEL, (1) 100A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37710	11041-10000-16817	1858 1/2 N ECHO PARK AVE	90026	13	142-5A211 146	5420030024	[Q]C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM			PC Approved	08/15/2011 12:00:00 AM	ADDRESS	34.08536	-118.25256	T.I.  Existing print shop.  Rennovating the interior and exterior light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37711	15041-20000-11226	6422 N WILKINSON AVE	91606	2	180B165   669	2333003021	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.18748	-118.40402	PV1. Standard plan for SFD. Install roof mounted PV system sized 8 kW. Interconnected with main service panel. (25) Sunpower 327 NE Modules(1) PVI-5000 TL Inverter(1) PVI-3.0 TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37712	12041-10000-20224	5736 N WOODLAKE AVE	91367	3	174B093   162	2041016021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.17475	-118.63189	INSTALLATION OF A ROOF-MOUNTED 9.2KW PHOTOVOLTAIC SYSTEM (ENPHASE M215 MICROINVERTERS).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37713	18041-10000-03538	735 S FIGUEROA ST #119	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.04878	-118.26079	TENANT IMPROVEMENT OF 783 S.F. WITH THE ADDITION OF PARTITION WALLS TO SEPARATE FRONT COUNTER AND FOOD PREP AREA. CHANGE OF USE FROM RETAIL TO TAKE-OUT RESTAURANT.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37714	11041-20000-09285	127 S SAN VICENTE BLVD Bulletin-57TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	Revision plan check only Bulletin # 57-TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37715	15041-20000-06379	496 N CRANE BLVD	90065	1	150A225   353	5467022025	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.1036	-118.20624	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (18) modules (18) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37716	10041-20000-14939	2614 W 7TH ST	90057	1	133-5A201 297			Central				2094.01	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM	08/02/2010 12:00:00 AM		Permit Closed	12/15/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	Temporary power service for new construction. 600 amp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37717	19041-20000-40375	18446 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37718	17041-20000-07549	506 N EVERGREEN AVE	90033	14	127-5A227  51	5178017001	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM			PC Info Complete	11/08/2017 12:00:00 AM	ADDRESS	34.04502	-118.19931	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 2 STORY HOTEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37719	14041-20000-07747	10250 W SANTA MONICA BLVD AMC	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to movie AMC theater in auditorium #14.  Plan check for power and signage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37720	15041-30000-39695	10574 N DES MOINES AVE	91326	12	207B117   336	2728005005	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.26266	-118.55575	Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect new inverter and modules with existing PV system.  Total system size = 6.7 kWac (3 kWac new).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37721	10041-20000-07417	11951 W CREST PL	90210	2	156B165   272	2382020048	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	06/03/2011 12:00:00 AM	ADDRESS	34.12206	-118.39764	SINGLE FAMILY DWELLING WITH GUEST HOUSE 1000a SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37722	12041-20000-15850	812 W 165TH PL Bldg B	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	33.88061	-118.28977	New electrical system for building B.  Power and energy.  Service is at building A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37723	19041-20000-27226	7423 N TUNNEY AVE	91335	3	186B117   555	2116016056	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.20548	-118.55723	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 10.395KW DC/9KW AC. SCOPE OF WORK INCLUDES (33) HANWHA Q CELLS AND A GINLONG SOLID1P9K INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37724	16041-30000-08144	9301 N TAMPA AVE Suite 179	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only in existing space. Total area: 1,512 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37725	18041-30000-47981	8479 W MELROSE PL	90069	5	141B173   428	5528001058	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.08373	-118.376	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,338 sq. ft.Note: Building application has been generated under 17014-20000-01472	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37726	14041-10000-17265	11338 W MOORPARK ST	91602	2	165B173   359	2366005020	[Q]C2-1XL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.15018	-118.37823	Title 24 plan check only.  Total area = 5,960 sq. ft.Building renovation including new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37727	19041-20000-52073	10205 N SAN FERNANDO ROAD	91331	7	204B161   326	2623024006	C2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM			PC Info Complete	12/17/2019 12:00:00 AM	ADDRESS	34.2557	-118.41139	T24 PLAN CHECK FOR ENERGY ONLY. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1413 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37728	11041-10000-19281	129 N LA BREA AVE	90036	5	138B181   707	5513002006	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM			PC Approved	09/12/2011 12:00:00 AM	ADDRESS	34.07442	-118.34423	TENANT IMPROVEMENT IN AN EXIATING RESTAURANTPLAN CHK IS FOR TITOLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37729	15041-10000-28745	4201 W WILSHIRE BLVD 1st floor	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.06189	-118.31911	TI to 1st floor interior corridor of (E) commercial highrise building.  Plan check for energy only. total area = 2555 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37730	15041-10002-34682	10109 N PARR AVE	91040	7	204B193  1273	2560031008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM			Reviewed by Supervisor	10/26/2015 12:00:00 AM	ADDRESS	34.25283	-118.3133	EXPEDITE PER CUSTOMER REQUEST.PV1.  Installation of 11.925 kW DC roof-mounted, utility-interactive PV system.   (2) ABB PVI-6000-OUTD-US inverters with (45) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37731	18041-10001-46963	3246 S BARBYDELL DR	90064	5	123B165   645	4316025009	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM			PC Approved	01/07/2019 12:00:00 AM	ADDRESS	34.0332	-118.40325	PC FOR NEW 10KW ROOFTOP PV SYSTEM AND 28KW ENERGY STORAGE SYSTEM, SCOPE INCLUDES (2) TESLA POWER WALL BATTERIES, (28) PV MODULES, AND (1) SE10000A INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37732	11041-10000-17374	1701 E CESAR E CHAVEZ AVE Ste 128	90033	14	130-5A221 204	5174007047	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.05126	-118.2173	T.I.  Suite number 128 medical office.  Remodel of light fixtures.  Plan check is for energy only.  The permit items have been inlcuded under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37733	12041-10000-08877	10667 W PICO BLVD	90064	5	126B157   577	4320008044	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Info Complete	04/19/2012 12:00:00 AM	ADDRESS	34.04245	-118.42411	CHANGE OF USE FROM RETAIL TO SPA WHERE A PERSON  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37734	14041-10000-21803	14832 W DELANO ST	91411	6	178-5A149 249	2241017008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.18238	-118.45653	Installation of new fire alarm system for 4 story 5 unit apartment. 24 devices and 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37735	11041-20000-09791	3415 S SEPULVEDA BLVD #470	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	"T.I. to a high rise building.  Install general/emergency of 4th floor.  Plan check for energy only.Note: ""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37736	19041-20001-44864	3522 N GRIFFITH PARK BLVD	90027	4	154-5A203 334	5592002012	R1-1	Central	Hollywood	Los Feliz		1882.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.11594	-118.27509	Expedite per applicant request  Plan check for PV and energy storage system, PV system size: 17.01KW with 54 PV Moduels and 2 inverters(7.6KW) 2 sub-panels and 2 energy storage(13.5KWh) Total energy storage system size: 27KWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37737	19041-20001-42591	17952 W KAREN DR	91316	5	168B129   587	2184023002	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM			PC Approved	11/15/2019 12:00:00 AM	ADDRESS	34.15509	-118.52378	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO PV MODULE MODEL AND LOWERING THE QUANTITY. CHANGE TO FRONT PAGE, ROOF LAYOUT, SINGLE LINE DIAGRAM, AND ELECTRICAL CALCULATIONS. PV SYSTEM SIZE IS UNCHANGED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37738	13041-10000-26004	380 WORLD WAY #3T42R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of 4 led sel-illuminated signs on the external walls of a the tenant space TUMI  on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the tye two frontal and two side signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37739	16041-10001-07250	1828 E CESAR E CHAVEZ AVE	90033	14	130-5A221 325	5174008022	C2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.05014	-118.21571	11/18/2016 Changes to an approved set of plans. Changes include relocate UPS panel from 5th to 4th Floor. Changes apply to delta 11 only{{{{[Change of use from medical office to primary care clinic OSHPD 3 on floors 4, 5, and 6; TI of 19400 s.f of interior construction on floors 1, 4, 5, and 6; new roof structure for equipment enclosure; restriping  on floor 1 and one new standard stall on parking level 3.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37740	10041-20000-09682	11740 W SAN VICENTE BLVD	90049	11	129B145    75	4265006074	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	07/21/2010 12:00:00 AM		Permit Finaled	08/26/2010 12:00:00 AM	ADDRESS	34.05308	-118.4669	TENANT IMPROVEMENT TO (E) FOOD ESTABLISHMENT, see comment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37741	15041-10000-15838	1412 N GLENDALE BLVD	90026	13	141A209   335	5419020017	C2-1L, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	34.08004	-118.25986	Change to an approved set by adding outdoor lighting (25-SQ feet)  and modifying interior lighting. ((((PC FOR ENERGY, T24. TI, CHANGE OF USE FROM RETAIL TO BAR/CAFE. TOTAL AREA 1901 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37742	18041-10000-19822	11251 W BURBANK BLVD	91601	2	174B173   909	2337035028	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1242.04	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Issued	05/30/2018 12:00:00 AM	ADDRESS	34.17232	-118.37651	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37743	19041-20000-44173	7435 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	04/29/2020 12:00:00 AM		Permit Finaled	03/06/2021 12:00:00 AM	ADDRESS	34.20582	-118.48615	$0 fee per AB1414Plan check for PV roof mounted system Feed In Tariff(FIT), PV system size: 496.8KW DC, 450.32KW AC CEC with 1242 PV modules and 10 inverters(33.3KW), connected service: 800A 480 3phase.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37744	12041-20000-05626	2029 CENTURY PARK EAST S.3170N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM			PC Approved	03/12/2012 12:00:00 AM	PIN	34.05957272	-118.4137405	OFFICE T.I.ENERGY, EMERGENCYFire/ Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37745	16041-20000-41882	700 S FLOWER ST Ste 575	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Highrise commercial office TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37746	13041-20000-34879	2919 S TILDEN AVE	90064	5	123B157  1295	4251004029	R1-1	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.02931	-118.42756	pv1 single family dwelling. total system size 3.8 kw ac using transformerless inverter nonstandard plan. 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37747	13041-20000-01673	4821 N LANKERSHIM BLVD	91601	4	168B173   395	2353025048	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.15818	-118.37082	tenant improvemnet petco store	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37748	16041-20000-02623	4096 S GLENCOE AVE	90292	11	108B153  1063	4230006003	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Expired	04/16/2018 12:00:00 AM	ADDRESS	33.98984	-118.44257	Plan check for energy only. Change of use from manufacturing to business (office). Redo core and shell, includes new lighting (incl. emergency) and receptacles. 8,019sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37749	19041-20000-41029	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37750	15041-10001-44011	10452 N FULLBRIGHT AVE	91311	12	207B113   242	2707017029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.26089	-118.57689	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 11550 WDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(42) MODULES:REC SOLR REC275TP(1) INVERTER: SOLAREDGE TECHNOLOGY SE 11400A-US 240V>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37751	11041-10003-27025	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.04661	-118.2324	REVISED PERMITTED SET OF PLANS :THIS IS VALUED ENGINEERING FOR BUILDING UNDER CONSTRUCTION-MINOR CHANGES TO LIGHTING SYSTEM FOR ALL FLOORS; OTHER CHANGES ARE OUTLINED IN SUBMITTED LIST OF CHANGES(((((((((((PROPOSED 6-STORIES MIXED USE BUILDING: RETAIL;APTS;LIVE/WORK UNITS;OFFICES;GARAGE;PORTION OF THE BUILDING IS 5-STORIES, TYPE IIIA, APTS OVER 1-STORY TYPE I GARAGE/RETAIL/OFFICE.OTHER PORTION IS 3-STORIES TYPE IIIA APTS OVER 3-STORIES TYPE I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37752	12041-20000-28214	8987 N LAUREL CANYON BLVD	91352	6	195B165   219	2629019012	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.2326	-118.40475	New shell only for a Medical Clinic.  Full plan check required.  Clinic will be licensed and must be check for OSHPD-3. Fire Alarm Variance has been filed.T. I. ENTIRE MED. CLINICS AND OFFICE BUILDING. ( SEE PLAN CHECK B12VN12624 FOR BUILDING SHELL AND CHANGING THE USE PERMIT )--MEDICAL CLINICS WITH NO CHRONIC DIALYSIS AND/OR SURGICAL SERVICE, NOT PLAN REVIEWED  FOR OSHPD III.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37753	14041-20002-34874	11826 W PALMS BLVD	90066	11	117B153   987	4249018022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.0141	-118.43272	05-21-15 Change to approved set to plan. Changes include relocate inverters, AC disconnect, and DC disconnect. Inverter and panel are now at the same location. {{{{{{{{{PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 10 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (40) SOLAR WORLD SW270 MONO MODULES(1) SOLAR EDGE 10,000A-US INVERTER(40) SOLAR EDGE P300 SOLAR OPTIMIZERS}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37754	16041-20000-26320	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.23162	-118.58832	Repair project for (E) commercial facility.  Substation S3A 150kVA repair: replace (6) circuit breakers and coil.  Substation S3B 500 kVA repair: Replace 5 kV switch and (6) circuit breakers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37755	10041-20000-06896	9000 W PICO BLVD	90035	5	132B169   871	4305007027	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM	12/10/2010 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.05505	-118.3879	renovation of an existing retail store	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37756	16041-20000-15150	20453 W HACKNEY ST	91306	3	192B109   475	2781025001	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.22258	-118.57939	PV1.  Install 5.2 kW rooftop mounted PV system.  (21) modules with 4.2kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37757	17041-20000-19256	4200 N RADFORD AVE BASEMENT	91604	2	165B169   370	2368001028	[Q]MR2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.14736	-118.39192	UPS module replacements in (E) commercial facility.  (3) 300 kVA UPS modules and (1) 80 kVA module.  New paralleling switchboard.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37758	16041-20001-20084	4211 N GAYLE DR	91356	3	165B117   324	2177005024	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.1474	-118.55142	EXPEDITEPV1INSTALL ROOF MOUNTED PV SYSTEM SIZE 13.7KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37759	13041-20002-29804	1500 W PACIFIC COAST HWY A-L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			02/18/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	02-18-2016 Change to approved set of plans. Changes include panel load(Methane load, exhaust fan load for Methane Detection System) UL listed panel for methane Detection System are not part of the plan. Methane Detection Panel are attached as cutsheet for each building (13 Buildings)Changes apply to Delta 13 only. Note: Methane Detection System Application reffer to 15041-10000-12870****************Previous work description****************************************************************************************************************************************************************************************************BUILDING A:   NEW APARTMENT COMPLEX CONTAINING 12 SEPERATE BUILDINGS UNDER THE SAME ADDRESS. (2) 4000A SERVICES. PER APPLICANT REQUEST SUBMITTED AS ONE LUMP SUM. METHANE ZONE, HAS METHANE REPORT.Note: Variance to separate Methane Detection System has been filed.Permit Bld. B is under 14041-20000-06842Bld. C is under 14041-20000-06845Bld. D is under 14041-20000-06846Bld. E is under 14041-20000-06848Bld. F1 is under 14041-20000-06850Bld. F2 is under 14041-20000-06875Bld. G is under 14041-20000-06852Bld. H is under 14041-20000-06853Bld. I is under 14041-20000-06854Bld. J is under 14041-20000-06856Bld. K is under 14041-20000-06858Bld. L is under 14041-20000-06859Bld. Recreation is under 14041-20000-06860*************************************************************************************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37760	14041-10001-07952	1619 W 10TH ST	90732	15	015B193   851	7560020014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	07/01/2014 12:00:00 AM	ADDRESS	33.73508	-118.31277	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 3.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(15) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37761	13041-10000-33021	3941 S BUCKINGHAM ROAD	90008	10	117B181   584	5045006010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.0152	-118.34156	PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (23) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37762	15041-10000-08774	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM ROW.FOR COFFE BEAN. PLAN CHECK FOR ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37763	11041-10000-02481	1021 S GLENDON AVE	90024	5	132B153  1086	4363021019		West Los Angeles				2077.10	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	09/13/2011 12:00:00 AM	ADDRESS	34.062	-118.44436	TENANT IMPROVEMENT FOR BANK (4,009 s.f., B occup.)  First tenant in new commercial space	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37764	19041-10000-48863	3914 S SOMERSET DR	90008	10	117B185  1002	5045015025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.01474	-118.33809	Plan check for photovoltiac system, system size is 3.135KW. 11 modules with P320 solaredge optimizers. (1) SE3800H inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37765	16041-10000-36853	11701 W MOORPARK ST	91604	2	165B169   266	2364010051	C1-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.15051	-118.38792	PC FOR TITLE 24. ENERGY ONLY.CHANGE OF USE FROM SALON TO A  RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA OF 1007 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37766	11041-10001-26854	3641 S WATT WAY 5th Floor	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.02033	-118.28801	Remodel to USC Labratory on the 5th floor in Rooms 512, 512A, 512B & 512C.  Lighting change, receptacles. Plan check for T-24 energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37767	10041-20000-02362	6710 N KESTER AVE 1st Floor	91405	6	180B149   177	2236004024	[Q]CR-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	02/25/2010 12:00:00 AM		Permit Finaled	10/12/2010 12:00:00 AM	ADDRESS	34.19266	-118.45723	Tenant improvement - remodeling the lighting only in the medical office. Title 24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37768	15041-20001-27500	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM			PC Approved	08/29/2015 12:00:00 AM	ADDRESS	34.28583	-118.51165	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (3) inverters, (57) modules, and (1) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37769	15041-10000-34883	547 S SEATON ST	90013	14	126A215   150	5163027010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.04008	-118.2373	ALTERATIONS IN OPEN STORAGE AREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37770	10041-10000-23788	528 S WESTERN AVE	90020	4	135B193   763	5503019015	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.06449	-118.30891	NEW COFFEE SHOP WITH OUTSIDE DINING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37771	15041-10001-37245	20339 W NORDHOFF ST	91311	12	195B113    59	2781001053	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM			PC Approved	07/18/2016 12:00:00 AM	ADDRESS	34.23201	-118.57696	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA  1 ON PLANS. CHANGES INCLUDE USE OF A CIRCUIT TO POWER GENERATOR HEATERS AND REDUCTION OF AC UNITS FOR SERVER ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37772	15041-10000-11055	19825 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	33.85044	-118.28713	T24 ONLY, REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 6624 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37773	18041-20000-26307	1835 S GREENFIELD AVE	90025	5	129B153   864	4323013044	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			07/13/2018 12:00:00 AM			PC Info Complete	10/10/2019 12:00:00 AM	ADDRESS	34.0474	-118.44047	New 4-story 16-unit apartment building.  2000A 208Y/120V 3ph-4w service.  Plan check for power and energy.  Building permit application under 18010-10000-02796.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37774	15041-20000-41568	4114 N GREEN MEADOW CT	91316	5	165B125   403	2184038029	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.14537	-118.52933	PV1 roof mounted solar installation 8kW AC system. interconnect with (Upgrade) 200A MS.(32) SW 275 Mono Black(32) ENPHASE M250-60-2LL-S2X(1) subpanel 100 AStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37775	13041-10000-27391	21720 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			Verifications in Progress	12/10/2013 12:00:00 AM	ADDRESS	34.18733	-118.60234	PLAN REVIEW FOR SIZING FEEDERS / CONDUITS FOR SUPPLYING NEW 35KV SERVICE AND POWER DISTRIBUTION EQUIPMENT FOR TOPANGA MALL RETAIL DEVELOPMENT (SEPARATE APPLICATION)PLAN CHK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37776	14041-10000-21971	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			Verifications in Progress	08/14/2014 12:00:00 AM	ADDRESS	33.94248	-118.40461	Title 24 plan check only.  Total area = 1,500 sq. ft. T.I. to airport terminal store - lighting and recepticles.Building application submitted before title 24 part 6 start date.  14016-10000-07827	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37777	14041-20000-15508	14652 W OTSEGO ST	91403	4	171A149   187	2263033044	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.16291	-118.45266	PV1Install roof-mounted solar array on SFD. System size: 5kW(21) EnPhase M250 microinverters(21) Solar World SW270 MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37778	16041-10000-43353	3601 S GAFFEY ST	90731	15	006B197     4	7469018904	OS-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Issued	12/09/2016 12:00:00 AM	ADDRESS	33.71121	-118.293	PROVIDE NEW FA SYSTEM. 51 DEVICES AND MAIN PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37779	12041-10000-22998	620 N STONE CANYON ROAD	90077	5	141B153   127	4362014017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2012 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.08362	-118.44384	New PV system 34.5 KW on SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37780	14041-10000-01245	2650 W TEMPLE ST	90026	13	138A203   249	5156027010	C2-1	Central	Westlake	Greater Echo Park Elysian		2086.20	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.07272	-118.27566	repacing lightsbin parking lot with LED, only T24 for outside	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37781	19041-20000-49431	8619 N JELLICO AVE	91325	12	195B129   538	2787031010	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	04/12/2020 12:00:00 AM	ADDRESS	34.22736	-118.51887	PV1.  Install 7.475 kW DC / 6.677 kW CEC-AC PV system with 13.5 kWh energy storage system.  (23) modules with (12) microinverters.  ***INSPECTOR TO VERIFY ALL CONDUCTOR LENGTHS INDICATED ON PLANS AND FAULT CURRENT CALCULATIONS***	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37782	10041-10000-10025	2140 E 7TH PL #A1-S	90021	14	124-5A217 350	5166003006	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM	06/08/2010 12:00:00 AM		Permit Finaled	07/06/2010 12:00:00 AM	ADDRESS	34.03337	-118.22846	Ti in an existing loft. Plan check for T24 & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37783	16041-30000-04531	11100 W RIVERSIDE DR 1-51	91602	4	165B173    88	2423011045	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			02/09/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.15214	-118.37265	Installation of fire alarm system in new 51 unit 3 story apartment building.  Total system size = 180 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37784	12041-20000-29396	13002 W WILLARD ST	91605	2	189B161   140	2304019019	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	01/02/2013 12:00:00 AM	ADDRESS	34.21812	-118.41671	New 7.1 kw photovoltaicy system for an existing single family residence.  System is an UNGROUNDED transformerless system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37785	12041-20000-24671	970 N MONUMENT ST #106	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.04646	-118.52393	Change to lighting in an existing office space with less than 400 amps of load, per applicant.  Low-rise building.  Plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37786	16041-20002-06296	21013 W SHERMAN WAY #3	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.20125	-118.5914	"11/15/2016 Changes to an approved set of plans. Changes have been made to certain fixture types. All changes have been reflected onto the Title 24 Compliance forms. *****Previous Work Description*****Revision to approved plan due to change of floor plan. T-24 remain the same. This is PC only, Permit shall be issued on master E# 16041-10000-06296<<PLANCHECK FOR T24 ENERGY. CHANGE OF USE RETAIL TO RESTAURANT. ""CORN N' CRAB "" 2,087 SQ. FT.>>B# 15016-10001-09179"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37787	15041-20000-16320	936 S OLIVE ST UNIT 248	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #18 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37788	14041-10000-13671	2515 E WHITTIER BLVD	90023	14	124-5A223 337	5185030012	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	10/13/2017 12:00:00 AM		Issued	10/13/2017 12:00:00 AM	ADDRESS	34.03356	-118.21345	expired design. New building permit applied for. Plan check for power and energy for panel and 600 amp service upgrade.All loads considered new.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37789	16041-10000-20472	2937 S HOBART BLVD	90018	8	120B193   261	5053009036	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.02792	-118.30794	PV1. 3KVA INVERTER (ABB =PVI 3.0), WITH 8 MODULES (KYOCERA, KU-60 SERIES)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37790	19041-10000-03889	3387-3389 N EAGLE ROCK BLVD	90065	1	153A215   110	5457024001	R3-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Apartment			01/31/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	09/19/2022 12:00:00 AM	ADDRESS	34.11443	-118.23648	Service upgrade to 600 Amp in a mixed use building / 2 unit Apt & future commercial space. Plan Check for power & energy. Building Permit: 18016-10000-01325	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37791	13041-10000-23896	18001 S FIGUEROA ST SUITE D	90248	15	063B201   174	7339008001	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	33.86778	-118.28182	Remove (E) HID light fixtures and install new light fixtures as per DWP rebate program.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37792	16041-10000-25640	1800 S AVENUE OF THE STARS STE 650	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Issued	07/21/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	T-24, PC FOR ENERGY ONLY. TI - NON-STRUCTURAL REMODEL OF AN EXISTING OFFICE SPACE FOR SUITE 650. SCOPE INCLUDES INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4335 SQ. FT. B#16016-10000-13296	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37793	13041-20000-35673	4415 S CENTRAL AVE 2ND FLR	90011	9	112-5A209 105	5108028023	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.00344	-118.25677	Change to lighting and receptacles in a Medical Office, low-rise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37794	12041-20002-30853	232 E 2ND ST	90012	14	129A213   468	5161024011	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Closed	11/14/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	07-22-2015 Changes to an approved set of plans. Changes include the addition of (3) panels and associated loads. All changes have been clouded and marked Delta 9.[[[[[Revisions to approved set. THERE IS A CHANGE OF ENGINEER ON RECORD. THIS PLAN CHECK TO TO SUPERCEED THE PREVIOUS APPROVED SET OF PLANS.  (((Construct 5-story,  240-unit apartment with retail over garage, no disabled access.  Located in methane buffer zone. title 24 included, emergency lighting.)))]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37795	14041-20000-02909	18019 W GAUGUIN ST	91344	12	219B129   377	2601024051	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	PIN	34.29709902	-118.52363508	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 3 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37796	14041-10000-15665	8510 N BALBOA BLVD	91325	12	192B133    87	2689019011	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.2251	-118.50158	Power and lighting plan check.  Total area = 15,500 sq. ft.  Tenant improvement - fill in shell building.  No exterior work on shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37797	15041-20001-17647	4740 N ARCOLA AVE	91602	4	168B177   594	2420023001	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.15699	-118.35479	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 10.9KW DC/ 9.5KW AC USING MICROINVERTER SYSTEM WITH ENPHASE M250. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37798	16041-10001-03673	606 E VENICE BLVD BUILD. B	90291	11	108B145  1741	4237002007	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.98922	-118.46166	02/09/16Changes to an approved set of plans. All changes are clouded under delta 8. Add one 200A panel, one new meter section, and EV chargers. PC for disaggregation of electrical loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37799	12041-10002-27812	4550 W PICO BLVD C314	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Approved	10/09/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	DELTA 4 CHANGES ONLY. ADDITION OF LIGHTING CONTROL DIAGRAMINFO FROM  12041-10001-27812 :CRA CLEARED IN 12041-10000-27812. INVESTIGATION FEE HAS TO BEEN ADDED TO THE FINAL FEES.FIRST TIME TENANT  GNC AT THE MID-TOWN CROSSINGINITIAL PLAN CHK IS FOR TITLE 24 ; THIS APPLICATION IS FOR FULL PLAN CHECK FOR THE POWER INSTALLATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37800	11041-10000-03495	814 N TOULON DR	90272	11	126B133    72	4408014022	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2011 12:00:00 AM			PC Info Complete	06/29/2011 12:00:00 AM	ADDRESS	34.04408	-118.50973	Two story SFD. new 600 amps service,  all panels and branch ckts new. customer's check is only $2895.27, therefore ckts from 177 is reduced to 151 units. notice to plan checker , add 27 additional ckts at final.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37801	12041-20000-03388	8825 S SEPULVEDA BLVD	90045	11	096B165   990	4122035027	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	09/10/2012 12:00:00 AM	ADDRESS	33.9565	-118.39648	T.I. to existing building (Ralphs).  New lighting, panels.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37802	13041-10000-31978	685 E MILFORD ST	90042	14	150A233    24	5312023039	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.10669	-118.17979	PV1 , ROOF-MOUNTED SOLAR (4.32KWdc) ARRAY INSTALLATION INTERCONNECTING TO EXISTING 200A MAIN. SYSTEM IS A MIXTURE OF MICROINVERTERS WITH A CENTRAL INVERTER, TO BE COMBINED @ 100A LOAD CENTER. WITH (11) SOLARWORLD 270W MODULES TO BE CONNECTED VIA 2500W KACO BLUEPLANET CENTRAL INVERTER, (5) ENPHASE M215 MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37803	10041-20000-22316	1936 S MATEO ST	90021	14	120A217   130	5167011036	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	09/12/2011 12:00:00 AM	ADDRESS	34.02257	-118.23228	Plan check 75.38KW Photovoltaic System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37804	13041-20000-10830	261 S FIGUEROA ST 280	90012	9	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			04/26/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.05546	-118.25446	Relocated some general light fixture in conference, office, and waiting rooms.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37805	11041-10004-19246	6701 N ETON AVE 1-298	91303	3	180B105    27	2148030035	(WC)C/I-60/1.0	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM			PC Approved	03/20/2013 12:00:00 AM	ADDRESS	34.19217	-118.59564	REVISED SET OF PLANS. SUPPLEMENTAL TO 11041-10003-19246.**********************************************************Revised permitted set of plans- added outlets to existing circuits 2nd floor fitness room;in electrical a remove inverter subpanel and decreased inverter fromm 8KVA to 6KVA;subpanel is relocatedt to garage main electrical room and connect to panel supplied by inverter in that room. inverter is increased 10KVA  Changes to previosly approved sets, , changes to title 24, feders and interior lightings.   No new ckt or panels. Revise elevator 1, 2, and 3, remove load from existing panels and relocate receptacle and luminaires. EPC is for delta I only. 9-13-12   (((((((((((((((((NEW FIVE-STORY, TYPE-III-A, 298-UNIT APARTMENT WITH ATTACHED PKG GARAGE (Automatic fire srpinkler throughout for the story increase). See separate permit  for attached parking garage.Need to file a variance to separate the FA plans from the electrical plans.Plan check fees were determined by client.))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37806	15041-10000-43908	11253 S COMPTON AVE	90059	15	087A211    52	6070012900	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	33.93195	-118.24712	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHTING AND REPLACE WITH LED FIXTURES.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 6800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37807	13041-10000-05426	470 E 3RD ST A-C	90013	9	129A215   263	5147004017	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.04621	-118.24052	New fire alarm system for a 3 story office building.  100 fire alarm devices, 1 new fire alarm panel, and 1 power supply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37808	17041-20000-35215	8968 N WHITE OAK AVE	91325	12	195B129    71	2768027001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Issued	10/12/2017 12:00:00 AM	ADDRESS	34.23445	-118.51982	Plan check for solar pv system, roof-mounted array on SFD.3kW ungrounded system. (12) 275W pv modules.Each module has a 320W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37809	16041-20001-26769	345 S NEW HAMPSHIRE AVE 1-66	90020	10	135B197   394	5502007009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.21	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.06775	-118.29309	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 40kW with 176 modules and 4 inverters(10.0kW) connected to MSP}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37810	13041-20000-22321	21650 W OXNARD ST FLR 7	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for energy and emergency lighting. 7th floor of commercial high-rise. Addition of offices. AIG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37811	16041-10000-42096	333 S HOPE ST 23rd FL	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 only in existing space T.I office space. Total area: 1,249 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37812	17041-10000-17086	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM			PC Info Complete	07/06/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	Power plan check only.  Disconnect 1500 kVA 2400-480/277 Volt unit substation in Building 96 from existing Olympic Substation and reconnect to existing Pico Substation at Fox Studios.  Project located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37813	19041-20001-36685	22121 W ERWIN ST	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18299	-118.60947	Expedite per applicant request Plan check for Pv roof mounted system, PV system size: 21.315KW DC, 18.9KW AC CEC with 49 PV Modules and 2 inverters( 9.0KW)Applicant reques: %%%%%%%%%%      Plan stay Van Nuys    %%%%%%%Note: This is 12 Buildings on 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37814	10041-20000-18889	21031 W VENTURA BLVD 2nd, 9th,-11th floor	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	PIN	34.16717222	-118.59179488	T.I. to exist high rise building.  Install general lighting in men/women restrooms of 2nd, 9th, and 11th floors.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37815	17041-20000-10656	8254 N HAVEN LANE	91325	6	192B133   535	2204001049	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.22061	-118.5072	pv1install roof mounted pv system sized 3.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37816	17041-20000-45443	2070 N HILLHURST AVE	90027	4	150B201   343	5590008003	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.10956	-118.28727	Plan check for energy only. TI for training facility classroom, conference room, and storage room. New lighting (incl. emergency) - 1,075sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37817	19041-10000-09169	1800 N PASADENA AVE	90031	1	138A219    38	5447021022	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.07311	-118.22313	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37818	12041-10000-23058	5601 W WILSHIRE BLVD	90036	4	135B181   891	5508013034	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.06252	-118.35061	TI in the parking structure for a grocory store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37819	19041-20000-29851	11175 N VIKING AVE	91326	12	210B121   207	2717004031	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.27311	-118.5434	Plan check for PV roof mounted system, PV system size: 12KW DC, 10KW AC with 40 PV Modules  and 1 inverter(10.0K)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37820	14041-10001-28433	145 N LA BREA AVE A-F	90036	5	138B181   632	5513002010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.07488	-118.34438	Change to approved set by removing main breaker from Panel PA and adding a 200-Amp 3P nonfused disconnect before the panel.  note, all changes apply to delta-2 only.PC FOR POWER AND ENERGY. CHANGE OF USE FOR A RESTURANT. TOTAL AREA  2587 SQ FT. FEES PER APPLICANT CALCULATION.(PER SHAUN )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37821	08041-10001-19283	3000 W 6TH ST 1st-2nd Floor	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown	YES	2111.20	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	03/22/2012 12:00:00 AM	PIN	34.06351748	-118.28745252	Changes from prevously approved plans.   Changes include the use of 2nd floor.  Part of 2nd floor is office and the other part is restuarant (kitchen).  1st floor remain unchange.  Plan check for power and energy.*****Place of Assembly, plan check power and energy for a proposed TI for restaurant 2 levels (1st & 2nd floor) in an existing building.  Existing service.  New transformer, panels, and ckts.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37822	16041-10000-09583	260 S MAIN ST	90012	14	129A213    26	5161026908	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.04961	-118.24558	Install Infrastructure for Phase 1, Electric Vehicle Charging station on LAPD Headquarters facility.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
37823	19041-10000-52739	5124 S BABETTE AVE	90066	11	105B161   524	4221011064	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	02/20/2020 12:00:00 AM		Issued	02/20/2020 12:00:00 AM	ADDRESS	33.9849	-118.4164	(E-PLAN) NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 100 AMPS. INSTALLATION INCLUDES 2 PANELS OF 125 AMPS, 1 ENERGY STORAGE SYSTEM, 1 CENTRAL INVERTER (SOLIVA 3.8 NA G4 TL), AND 12 MODULES (Q.PEAK DUO BLK-G5 315)  SYSTEM SIZE: 3.78 KW DC; 3.8 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37824	15041-20000-36917	10909 W HARTSOOK ST	91601	2	171B173   761	2419001027	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Apartment			11/03/2015 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.16365	-118.3685	Plan check for power and energy. Project site is a new 27-unit, 3-story apartment building. Work includes a 1200-amp service, associated distribution equipment, (27) unit panels, a total indoor lighting area of 15,001 sq. ft., and a total outdoor lighting area of 4,760 sq. ft.Note: Building application has been filed under 15010-10000-02804	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37825	18041-20000-34858	20215 W STAGG ST	91306	3	189B113  1358	2107021080	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.21086	-118.57357	pv1install roof mounted pv system sized 7.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37826	12041-20002-02012	5802 W WILLOUGHBY AVE	90038	13	144B189  1034	5534029003	[Q]C2-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.08696	-118.32253	Modifications to previously approved set of plans.  T24 and emrgency lighting and power has been modified.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37827	19041-20000-13379	5900 W WILSHIRE BLVD Ste 2350	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37828	12041-10000-28977	2013 S PATTON AVE	90732	15	012B193  1129	7460014013	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2973.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2012 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.72576	-118.30576	NEW ROOF MOUNTED 7.85 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37829	17041-20001-36690	11801 W MISSISSIPPI AVE 1-2 flr	90025	11	123B149   359	4262033020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.03444	-118.45125	Revisions to approved set of plans.  Change of source of EM supply for exit signs from inverter to 90 minute integral battery back-up.  Clouded revisions delta-1 only.  (((ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37830	11041-10000-10977	4501 S GLENCOE AVE	90292	11	105B153   614	4212007008	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	33.9849	-118.43588	T.I.  Exisitng show room space for shoes.  Remodeiling light fixtures.  Plan check is for energy and emergency lights.  Title-24 using Tailored Method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37831	16041-10000-09451	222 N PARK VIEW ST	90026	13	136-5A205  23	5157012008	RD2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			03/17/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.07029	-118.27229	PV2, rooftop solar installation under 4 unit (multifamily) dwelling. 3kW system.    (9) KU2656ZPA      (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37832	14041-10000-28943	10979 W BLUFFSIDE DR BLDG 2	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	Note to plan check engineer, applicant returns and swaps in a new plan with additional circuitss added on after original fee was paid. Plan check engineer needs to verify fee with all new changes. per F.Y.(((Installing new washer/dryers and booster fans in apartment units.  Bldg 2 of 6.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37833	18041-10000-38213	750 S LAMAR ST OUTBOUND-PORTAL	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (F) OUTBOUND PORTAL6 OF 10BUILDING PERMIT 13010-10000-00550	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37834	15041-10000-32019	9301 N TAMPA AVE #180A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Issued	11/05/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (RETAIL). SCOPE INCLUDES NEW LIGHTS AND 1 NEW PANEL. TOTAL AREA IS 712 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37835	14041-10001-20580	525 S HEWITT ST	90013	14	126A215    76	5163023900	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	34.04076	-118.2351	VOID<<<<PV2, INSTALL 178500  KW D, ROOF-MOUNTED SOLAR ARRAY ON A OFFICE BUILDING (DWP), INTERCONNECT WITH EXISTING UTILTY SERVICE.(720) MODULES(2) INVERTERS: ONE I00KW & ONE 75 KW>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37836	16041-20000-01325	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.24253	-118.57768	Plancheck for Fire alarm. Addition of 2 RPS and 101 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37837	16041-20000-24526	1999 S BUNDY DR 2nd Floor	90025	11	123B149   406	4259019007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.03406	-118.45593	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,261 sq. ft.Note: Building application has been created under 16016-10000-00879	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37838	13041-10000-24990	701 S LINCOLN BLVD	90291	11	111B145   898	4239005030	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	33.9995	-118.46452	TITLE-24 TENANT IMPROVEMENT FOR A VEGETARIAN SANDWICH SHOP. COVERTED FROM A YOGURT SHOP TO A SANDWICH SHOP IN A SINGLE-STORY BUILDING.1078 TOTAL SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37839	19041-10000-28635	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	09/17/2020 12:00:00 AM		Permit Finaled	02/01/2021 12:00:00 AM	ADDRESS	33.78054	-118.23195	PHASE 1 POWER PLAN CHECK FOR THE ADDITION OF 2 1500KVA TRANSFORMERS CONNECTED TO 3000A MEDIUM VOLTAGE EXISTING SWITCHGEAR. THE SCOPE IS FOR THE 5KV  ELECTRICAL CABLE CONNECTION FROM EXISTING SWITCHGEAR (MEDIUM VOLTAGE) TO THE PRIMARY OF THE TRANSFORMER. ALL OTHER EQUIPMENT FROM THE SECONDARY OF THE TRANSFORMER ARE SHOWN FOR REFERANCE ONLY AND WILL BE SUBMITTED UNDER PHASE 2. Customer discription: INSTALLATION OF 5KV ELECTRICAL CABLE IN EXISTING UNDERGROUND DUCT BANKS. 5KV CABLE CONNECTIONS TO NEW BREAKERS IN EXISTING SWITCHGEAR (SUB 7) AND CONNECTION TO NEW OIL FILLED TRANSFORMERS FOR NEW SUN 10.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37840	15041-20000-03674	110 E 9TH ST # AL21	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.04107	-118.25479	INTERIOR TENANT IMPROVEMENT TO (E) OFFICE (1,120.0 SQ. FT) AT GROUND FLOOR TO ADD NEW COUNTERS, REPLACE CEILING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37841	16041-20000-29708	14738 W FLORENTINE ST	91342	7	219B149   289	2506033063	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Expired	10/02/2018 12:00:00 AM	ADDRESS	34.29881	-118.45421	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37842	19041-10000-33912	189 S THE GROVE DR #2	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	11/22/2022 12:00:00 AM	ADDRESS	34.07125	-118.35662	ENERGY PC ONLY FOR TENANT IMPROVEMENT TO (E) RETAIL  (NON STRUCTURAL). TAILOR METHOD EMPLOYED. AREA OF SCOPE 4,695SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37843	14041-20001-05564	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.0352	-118.45736	changes to T24, site lighting. pc for changes only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37844	19041-10000-11848	1149 S HILL ST 10TH FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.03926	-118.26099	Energy plan check for a tenant T.I on the whole floor of 10th floor of a high rise building. Scope includes new lighting and equipment with a total area of 22029-SQ FT.Bld #: 19016-10000-07191	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37845	18041-20000-23673	12648 W MILLENNIUM	90094	11	102B161  1280	4211037036	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	33.97707	-118.41342	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37846	13041-10000-05687	333 S FIGUEROA ST 1ST FLOOR	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.05436	-118.25543	[][][]TITLE-24 EXPRESS PERMIT TO BE PULLED ][][T24 FOR RENOVATION OF EXISTING RESTAURANT AND LOBBY AREA OF EXISTING HIGH RISE HOTEL (FIRST FLOOR). 9080 SQRFT AND 11,880. PLAN CHECK UNDER ONE APPLICATION NUMBER HOWEVER THE PERMIT WILL BE PULLED IN 2 SEPERATE PHASES. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37847	17041-10000-28774	11980 W FOXBORO DR	90049	11	132B141   273	4404018028	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Expired	09/28/2023 12:00:00 AM	ADDRESS	34.05968	-118.47423	PC FOR PV SYSTEM WITH BATTERY STORAGE UNIT. TOTAL OF 12 MODULES, CENTRAL 3.8KW INVERTER AND ENERGY STORAGE UNIT RATED 5.8KW.Zero fee pemit per Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37848	14041-10001-01418	601-605 E 6TH ST	90013	14	127-5A213 533	5147023026	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	PIN	34.04183685	-118.24406176	Title 24 plan check per inspector correction notice.  (((REPLACE 5 CIRCUITS AND 16 LIGHTS (REFERENCE BLDG PERMIT # 13016-10000-18609))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37849	18041-10001-00212	20945 W ROSCOE BLVD	91304	3	192B109   680	2779007019	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.22007	-118.58997	[[4/6/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ONLY. CHANGES TO LIGHTING]]]Energy plan check for a fire damage remodeling. Scope includes new lighting and equipment. Total area is 2345 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37850	11041-10001-22185	852 S BROADWAY	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM			PC Approved	02/06/2012 12:00:00 AM	ADDRESS	34.04246	-118.2557	CHANGES MADE IN THE FIELD-PANEL F AND TRANSFORMER REMOVED ; A FEEDER FROM MSA SUPPLIES 400A PANEL A WHICH SUBFEEDS PANELS B AND C; SINGLE PHASE DISTRIBUTION BOARD SUPPLIES PANELS D AND E; LOADS ARE REDISTRIBUTED TO THESE PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37851	13041-10001-30815	7752 N FARRALONE AVE	91304	3	189B101   709	2012030020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.21148	-118.61016	Expedited RSES plan check per applicant request. (((PV1, Install 2.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 9 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37852	13041-20000-34061	6438 N AGNES AVE	91606	2	180B165   633	2322007037	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.18793	-118.39526	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.16KW AC USING 10 MICROINVERTERS STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37853	19041-20000-19705	8300 N SAN FERNANDO ROAD	91352	6	192B173   512	2632026019	[Q]M2-1-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.22	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.22126	-118.37118	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR EXISTING COMMERCIAL INDUSTRIAL. PV SYSTEM SIZE IS 745.6KW DC/566.1KW AC/676.4KW AC 0$ fees due to assambly bill 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37854	19041-10000-17586	12227 N BALBOA BLVD	91344	12	216B133    12	2606001020	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.29219	-118.50227	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37855	13041-10000-07458	5801 N ROLLING ROAD	91367	3	174B101    59	2146018016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	08/01/2013 12:00:00 AM	ADDRESS	34.1763	-118.60826	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11.76 KW. USING TOTAL OF 48 MODULES. STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37856	08041-10004-06267	609 S ST PAUL AVE	90017	1	130-5A207  24	5143025002	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			10/07/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.05337	-118.26134	REVISIONS TO a permitted set of plans -Delta 3 . Changes were made tin the common area : enlarged theatre; installed a dimmer panel; few new circuits ; changes in the lighting system in the conditioned space of the common area. Plans are AS-built sets.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37857	18041-10001-43609	3501 W SUNSET BLVD	90026	13	144A203   188	5429024001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM			PC Approved	10/02/2019 12:00:00 AM	ADDRESS	34.08906	-118.27633	Changes to the approved plans for relocating the service from outdoor to indoor.<<<Service upgrade to 600 Amp in a single story commercial building with multi tenants. There are NO connected load to the service. Future TI's will require plan check.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37858	11041-20000-21797	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM			PC Approved	11/07/2011 12:00:00 AM	ADDRESS	34.32381	-118.49103	T.I.  Office remodel of the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37859	14041-20000-11781	308 S BRISTOL AVE	90049	11	129B137   120	4405023004	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	ADDRESS	34.05273	-118.48688	600A main service upgrade and associated service equipment for single family dwelling.  (2) new subpanels with loads to be installed under future permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37860	16041-20000-14762	5433 N SAN FERNANDO ROAD WEST	90039	13	165B201    86	5593008008	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.1511	-118.2751	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to office areas and printing and graphics areas. Total lighting area = 13,845 sq. ft.Note: Building application has been created under 16016-20000-09421	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37861	17041-10000-17158	10250 W SANTA MONICA BLVD # 2980	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	FIRST TENANT-SUPERDRY- AT CENTURY CITY MALL	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37862	15041-10000-14210	10602 W KESWICK ST	91352	2	186B177    30	2466029009	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.21037	-118.36201	Energy plan check for a warehouse of a commercial building by removing HID light and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37863	16041-10000-21303	624 S GRAND AVE	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.04802	-118.25572	pc for t24 energy only for lighitng in future electrical rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37864	13041-20000-14676	13268 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW. USING 15 MODULES ENPHASE MICROINVERTER M215. STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37865	14041-10000-17384	1800 S CENTURY PARK EAST 5TH FLOOR	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.06244	-118.41523	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT OF HIGHRISE BUILDING. SCOPE OF WORK IS ON THE FIFTH FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37866	14041-20000-24314	1417-1423 E 15TH ST	90021	14	121-5A213 345	5130012011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Closed	09/02/2021 12:00:00 AM	ADDRESS	34.02529	-118.24466	NEW 600AMP SERVICE FOR THREE COMMERCIAL BUILDINGS ADJACENT TO EACH OTHER.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37867	17041-20001-00749	1700 W SUNSET BLVD MEZZ	90026	13	139-5A209 152	5404017020	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.0771	-118.25863	5/15/17changes to an approved set of plans.  changes include lighitng fixture types and recalculation of energy compliance.  changes under delta 1.  this is plan check only. (((((Plan check for energy only. TI to 4,465sqft office space. New lighting (incl. emergency).)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37868	19041-10000-48094	384 WORLD WAY M45	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	04/13/2022 12:00:00 AM		Permit Finaled	04/23/2022 12:00:00 AM	ADDRESS	33.94339	-118.40887	"FIRST TIME TENANT IN UNIT #M45 - COMMERCIAL / RETAIL SPACE IN TERMINAL ""MSC"" IN LAX. INSTALLING PANELS, CIRCUITS & LIGHTS.  PLAN CHECK FOR POWER & ENERGY. AFFECTED AREA: 2,540 SFT ***M45 - WILSHIRE & FAIRFAX***"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37869	16041-20000-03564	8155 N KATHERINE AVE	91402	6	192B153  1013	2212017018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.21983	-118.44251	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. Each module has a 300W power optimizer. (19) 270W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37870	11041-20000-11569	555 W 5TH ST 11th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Finaled	02/17/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I.  on the 11th floor of high rise building.  Replacing and installing new light fixtures and emergency lights.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37871	16041-20000-29921	5757 W WILSHIRE BLVD 6th Floor-Corridor	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for energy only. New lighting (incl. emergency) in 6th floor corridor of existing office building. 3,949sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37872	12041-10000-03181	4818 N BRUGES AVE	91364	3	168B097   249	2074006025	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.15853	-118.62591	Plan check roof mounted 1.38KW Enphase M215 Microinverter photovoltaic system for a single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37873	13041-20000-24236	22034 W TIARA ST	91367	3	177B101   247	2146016007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Expired	10/01/2015 12:00:00 AM	ADDRESS	34.17815	-118.60707	PV1 SINGLE FAMILY DWELING TOTAL SYSTEM SIZE 3.6 KW AC USING 17 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37874	19041-10001-08003	301-445 N FIGUEROA ST	90744		027B201     9	7417002032							Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM			PC Approved	04/02/2020 12:00:00 AM	ADDRESS	33.77206	-118.27885	EXPEDITE PER APPLICANT REQUEST..(((PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 2776 MODULES (Q-PEAK 395), 1404 OPTIMIZERS (P850 ) AND 9 INVERTERS ( SE 99.9K). SYSTEM SIZE IS 900KWac AND 1096KWdc)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37875	19041-10000-28257	200 N SPRING ST	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	06/22/2021 12:00:00 AM	ADDRESS	34.05405	-118.24317	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING BUILDING LA CITY HALL. SCOPE OF WORK INCLUDES 86,996 SQFT OUTDOOR/FACADE LIGHTING FOR PHASE 3 ONLY. ALL USING EXISTING CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37876	17041-10000-15410	700 W OLYMPIC BLVD	90015	14	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Info Complete	05/25/2017 12:00:00 AM	ADDRESS	34.04441	-118.26318	PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO (E) OFFICE (NO CHANGE OF USE). NEW LIGHTING. AREA: 7341 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37877	18041-30000-15961	6922 W HOLLYWOOD BLVD 6TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLAN CHECK FOR T24 ONLY, INSTALL NEW LIGHTS AND RECEPTACLES IN RESTROOM ON THE 6TH FLOOR. APPROX 359 SF TOTAL. CIRCUITS ARE PROVIDED FROM EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37878	18041-10000-45023	6543 N TAMPA AVE	91335	3	180B117   586	2131009018	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.18959	-118.55376	PC FOR NEW ROOFTOP PV SYSTEM FOR (E) SFD. 3.8KW AC SYSTEM, (13) SOLAR MODULES, (1) 3.8KW SE3800H-US INVERTER, (13) P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37879	19041-20000-39034	1355 N VINE ST BLDG B	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	06/04/2020 12:00:00 AM		Permit Finaled	06/03/2021 12:00:00 AM	ADDRESS	34.0956	-118.32685	"FULL PLAN CHECK FOR INTERIOR TENANT IMPROVEMENTS TO BUILDING ""B"" -  LEVEL 01.SCOPE OF WORK CONSISTS OF MOTORS, TRANSFORMERS, BRANCH CIRCUITS, LIGHTS, T24, AND PANELS. TOTAL SQUARE FOOTAGE = 44793 SFBUILDING PERMIT UNDER 19016-10000-28207"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37880	10041-20000-21054	8925-8933 N GLENOAKS BLVD	91352	6	195B173   260	2408006038	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Apartment			10/22/2010 12:00:00 AM	10/22/2010 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.23074	-118.36767	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37881	17041-10000-07836	8337 W ANTHONY CIR	90046	4	150A173   248	5567023029	R1-1	Central	Hollywood	Bel Air - Beverly Crest	Yes	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.10607	-118.37332	Plan check for PV roof mounted system. System size: 3.0 kW with center feed panel 7 modules and 1 inverter(3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37882	17041-20001-45866	13548 W VENTURA BLVD	91423	4	165B157   746	2373011004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.14744	-118.42876	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM BEER TAVERN TO PRE SCHOOL. PLANCHECK ONLY.  PERMIT UNDER 17041-20000-45866.Change of use from beer tavern to pre-school.  Tenant improvement - plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37883	15041-10000-17975	2753 W WAVERLY DR BLDG 7	90039	4	151-5A207 233	5438025***	RD2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.10855	-118.26334	NEW DEVELOPMENT FOR MULTI BUILDING TOWNHOUSES 600 AMP SERVICE.  THIS IS BUILDING 2 OF 5.  PLAN CHECK FOR POWER AND ENERGY.  EACH BUILDING HAS ITS OWN SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37884	18041-10002-32413	5628 E KENDALL AVE	90032	14	147A239    41	5309026020	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	05/04/2019 12:00:00 AM	ADDRESS	34.09851	-118.1574	<<<No Fee due to Assembly Bill AB1414>>>>SUPPL. APPLICATION TO APPROVED PLANS FOR ADDING ONE PV PANEL FOR A TOTAL OF: 12.39 KW (DC) ROOF MOUNTED PV SOLAR SYSTEM WITH 42 PV MODULES ON A SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37885	16041-10000-16011	2715 1/2 E MALABAR ST	90033	14	129A225   140	5177024004	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.04814	-118.20151	PV1 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER. (12) MODULES AND (1) 3.8KW- INVERTER. TOTAL SYSTEM SIZE IS 3.8KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37886	15041-20001-10035	12452 W OSPREY LANE #1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	Supplemental application for expedite fees.Installation of new roof mounted solar PV array on 3 unit apartment building (triplex).  Each unit panel is fed by a seperate inverter (3 inverters total).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37887	14041-20000-03594	8407 N CREBS AVE	91324	12	192B121   500	2785013026	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.22305	-118.54386	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37888	13041-10000-01615	612 W HELLMAN WAY	90089	9	118-5A201   5	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	01/23/2013 12:00:00 AM	PIN	34.02015856	-118.28226229	New lighting for USC common area. TI work at the first floor. 3593 sqr feet. 5 story building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37889	14041-20000-06908	23674 W DRACO WAY	91307	12	186B093   609	2027014008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.20318	-118.64278	pv1 single family dwelling. total system size 6kw ac using transformerless inverter nonstandard plan. 2 strings	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37890	13041-20000-18981	11414 W CHALON ROAD	90049	5	144B145   240	4369027003	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.08807	-118.46354	Plan check for energy and emergency lighting. ADA modifications to restrooms. JTD School. Building permit is on 13016-20000-10205.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37891	12041-10000-04905	5105 E YORK BLVD	90042	14	156A225   289	5478001016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	04/19/2012 12:00:00 AM	ADDRESS	34.12115	-118.20447	New Ice Cream shop.  New lighting, receptacles, loads.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37892	13041-10000-23742	601 S FIGUEROA ST SUITE 500	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR TITLE 24 ONLY. EMERGENCY LIGHTING. 3206 SQFT. HIGH RISE. WORK IS ON 5TH FLOOR. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37893	15041-20001-25592	11140 N YOLANDA AVE	91326	12	210B121   215	2717004009	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.27271	-118.54404	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (35) panels, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37894	16041-20000-23845	2189-2195 E WHITTIER BLVD	90023	14	124-5A221 121	5183021023	R3-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.03614	-118.21937	Full plan check. Repair of fire demage to a commerical building single story core and shell, 3 different tenant spaces. New service rated at 800 amps 120/240 3phase 4 wire. Installing lighting and power. Total sqft = 7597.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37895	12041-20000-14074	11736 W WASHINGTON PL	90066	11	111B157    68	4233008017	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.00402	-118.42155	Convert from retail to take-out restuarant.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37896	19041-10000-49737	1925 S CENTURY PARK EAST STE 900--990	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Issued	12/12/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	Energy plan check only , area of scope (3554)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37897	11041-10000-02279	554 S BROADWAY	90007						CENTRAL CITY				Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM			PC Approved	02/04/2011 12:00:00 AM				INTERIOR ALTERATIONS IN  A RETAIL STORE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37898	16041-10000-17135	623 N ALMA REAL DR	90272	11	126B129   767	4411019027	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.03874	-118.52385	NOTE: PERMIT FEE IS $0 DUE TO SENATE BILL 1222.((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.68KWdc / 13.44KWac.(56)MODULES-LG280S1C-B3(56)MICROINVERTERS-ENPHASE M250-60-2LL no fees due to senate bill 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37899	14041-10000-11585	25965 S NORMANDIE AVE LEVEL 2	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	T24 FOR EXISTING MEDICAL BUILDING. RETROFITTING LIGHTS ONLY. CONVERTING FLOURESCENT FIXTURES TO LED FIXTURES. RETROFIT KIT IS UL LISTED FOR THE APPLICATION. SCOPE OF WORK IS ON THE 2ND FLR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37900	14041-10000-12580	650 S GRAND AVE	90014	14	129A209   129	5144004028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	PIN	34.0473798	-118.25622156	PLAN CHECK FOR NEW 1000 AMP SERVICE FOR HIGHRISE BUILDING. RELOCATING LOADS FROM OTHER SERVICE. THERE ARE MULTIPLE SERVICES IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37901	19041-20000-39395	992 W 8TH ST	90017	14	129A207    85	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	04/10/2020 12:00:00 AM	ADDRESS	34.04846	-118.26264	CHANGE OF USE TO RESTAURANT FIRST TIME TENANT.  ADD NEW PANELS, EQUIPMENTS, AND LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37902	14041-20002-14075	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.03497	-118.45709	[[1/29/15  CHANGES TO APPROVED SET PER INSPECTORS REQUEST TO UPDATE PLANS. REMOVING DISCONNECT SWITCH FOR THE OPTIONAL STANDBY EMERGENCY GENERATOR ONLY . DELTA 6 CHANGE ONLY]]]]]supplemental permit under original permit number 14041 20000 14075 for modifications to lighting noted delta 5 on new plans.Remodeling of single-story commercial office building on campus.  Existing service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37903	18041-20000-27873	6526-6528 W SUNSET BLVD 1ST, 2ND-FLR	90028	13	147A187   165	5547026048	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.09776	-118.33241	Tenant improvement of (E) 2-story office building interior.  Plan check for Title 24 Part 6 energy only. Building permit under 18016-10000-23280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37904	16041-10000-16569	350 S GRAND AVE 28 FLR	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	PC ENERGY ONLY FOR A HIGH RISE BUILDING, WORK IS BEING DONE IN THE 28TH FLOOR.  INSTALL (27) LIGHTS AND (6) RECEPTACLES. TOTAL SQ FT = 1970. Permit is paid under 16041-10000-15263.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37905	13041-20000-08457	9131 N OAKDALE AVE	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Closed	06/29/2018 12:00:00 AM	ADDRESS	34.23697	-118.56716	Change to lighting in an existing office building.  NOT A MEDICAL BUILDING PER APPLICANT.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, No Emergency lighting.  Permit fees are under Inspection.  Misc Permit is for Low-Voltage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37906	17041-10000-23252	9017 W PICO BLVD	90035	5	132B169   777	4332008023	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.05543	-118.38827	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37907	10041-20001-19789	14629 W NORDHOFF ST	91402	6	198B149   557	2651009021	[T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Info Complete	03/09/2011 12:00:00 AM	ADDRESS	34.23558	-118.45117	revision to energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37908	11041-10000-16391	20103 W SATICOY ST	91306	3	186B113   177	2114004047	C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.20848	-118.57128	T.I.  Existing 7-Eleven.  Replacing the light fixtures in the retail area only.  Replacing the flourescent fixtures with LED fixtures.  PLan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37909	17041-10000-04288	18420 W KINZIE ST	91325	12	201B125   222	2764005024	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.24796	-118.53495	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 53,775.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37910	12041-10000-23268	3352-3354 W OLYMPIC BLVD	90019	10	129B193   297	5080002022	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM			PC Approved	10/01/2012 12:00:00 AM	ADDRESS	34.05243	-118.3109	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM OFFICE TO DENTAL OFFICE. ORIGINAL APPROVED PLANS WERE LOST. PERMIT ISSUDED #12041-10000-17722.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37911	17041-10000-30303	2902 W WILSHIRE BLVD TEMP	90010	10	133-5A201  47	5077013034	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Closed	03/11/2022 12:00:00 AM	ADDRESS	34.06164	-118.28452	PC FOR TEMP POWER INSTALLATION FOR CONSTRUCTION. SCOPE INCLUDES 2 TEMP SERVICES RATED 1000A @ 480V PROVIDE POWER FOR CABLE RISERS AND MINI SUBSTATIONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37912	18041-10000-42467	10250 W SANTA MONICA BLVD #2915	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Issued	11/27/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR INSTALLING (2) PANELS (1 100A, 1 225A), (1) 30KVA TRANSFORMER, GENERAL RECEPTACLES AND LIGHTING FOR SHELL SPACE. CONNECTING TO EXISTING 2500 A SERVICE IN SUITE # 2915.BLDG PERMIT# 18016-10000-35957	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37913	13041-20000-05858	4027 N FARMDALE AVE	91604	2	162B169   400	2368023037	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.14113	-118.38132	Enphase system on roof of single family dwelling with ac conductors run in attic and walls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37914	16041-10001-43801	12746 W JEFFERSON BLVD 1-3	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Issued	06/30/2017 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGES TO PANEL SCHEDULE LAYOUT AND UPDATED FLOOR PLANS. ALSO UPDATED LIGHTING TO MATCH AS BUILT. SINGLE LINE CHANGE INCLUDES REMOVAL OF PANELS AND MADE OTHERS DOUBLE SECTION. LITTLE ADDITIONAL EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37915	13041-10000-19299	800 N SEPULVEDA BLVD	90049	5	138B145    44	4368014020	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.07812	-118.4696	Conversion of service bay to convenience store in existing service station building.  24 hour operations. Service upgrade to 600A.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37916	10041-20000-08795	17975 W VENTURA BLVD	91316	5	171B129   190	2162006001	P-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	ADDRESS	34.16451	-118.52397	NEW PANELS, LIGHTING AND POWER FOR RETAIL STORE. P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37917	14041-20000-30341	4520 N WOODLEY AVE	91436	5	168B141   757	2283012032	RE15-1-H	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.15394	-118.48338	"""0$ permit fees due to senate bill 1222""PV1 SFD. TOTAL SYSTEM SIZE 18KW AC USING 72 MODULES. USING MICROINVERTER SYSTEM. MICROINVERTER ENPHASE M250. NONSTANDARD PLAN."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37918	18041-10000-24708	11305 W SANTA MONICA BLVD	90025	11	129B149   420	4261007027	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.04653	-118.4489	TITLE 24 ONLY FOR THE REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37919	15041-10000-26532	633 W 5TH ST LEVEL 2	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY. NEW KIOSK OUTSIDE AREA, LEVEL 2. TOTAL  AREA  85 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37920	13041-10000-34462	6726 N KENTLAND AVE	91307	12	180B101   107	2038031001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.1926	-118.61746	PV1, Install a 4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37921	15041-20001-34290	11933 W ALLEGHENY ST	91352	6	198B165   177	2631001016	RA-1, [Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.23744	-118.39294	"upgrade panel ""BH"" from 400 amp to 600 amp.  plan check for power only.this is plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37922	19041-10000-44494	20610 W LUGANO WAY	91326	12	213B109   267	2701064027	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.27958	-118.58197	(E-PLAN)NEW ROOF-MOUNTED PV1 INSTALLATION WITH AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 36 MODULES ( LG370Q1C-V5 ), 36 MICRO-INVERTERS (ENPHASE IQ7PLUS-72-2-US), AND 1 COMBINER BOXSYSTEM SIZE: 13.32KW DC; 10.44 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37923	15041-20000-13864	6320 N TOPANGA CANYON BLVD G-1617	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for 1st time tenant(Skin Laundry) Westfield Mall BLDG G-1617. Total area: 1438 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37924	17041-10000-18506	1720 N WILTON PL	90028	13	148-5A193  84	5544002066	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.1024	-118.31352	PC FOR PV2 ROOFTOP SOLAR SYSTEM. SYSTEM IS 3.6KW AC USING CENTRAL INVERTER AND 14 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37925	18041-10000-42767	3523 S CENTINELA AVE 2-7	90066	11	114B153   477	4246006001	[Q]C1-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.00999	-118.43857	PLAN CHECK FOR POWER ONLY FOR UPGRADE OF EXISTING 600A 120/240 SINGLE PHASE SERVICE TO 800A 120/240 SERVICE. ALL EXISTING PANELS TO REMAIN AND RECONNECTED TO NEW SERVICE. (NO NEW LOADS TO BUILDING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37926	18041-10000-04160	2714 S FORRESTER DR	90064	5	126B165   197	4308006019	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM			Reviewed by Supervisor	02/12/2018 12:00:00 AM	ADDRESS	34.04379	-118.40398	PC for three new AC powerwalls(13.5kWh 5.8kVA) for a single family residence. Also adding one new 125A Subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37927	18041-10000-39711	8941 N TAMPA AVE	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.23285	-118.55413	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37928	15041-10000-39034	222 S HOPE ST	90012	14	132A211    90	5151004***	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Expired	12/21/2017 12:00:00 AM	ADDRESS	34.05463	-118.25117	PC FOR OUTDOOR LIGHITNG. OUTDOOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37929	14041-10000-05723	14853 W STRATHERN ST	91402	6	189B149   279	2209039009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Expired	03/28/2016 12:00:00 AM	ADDRESS	34.21621	-118.45704	PV1. ROOFMOUNTED SOLAR SYSTEM WITH POWER OPTOMIZERS. TRANFORMERLESS INVERTER. SYSTEM SIZE: 3 KW DC.(12) CANADIAN SOLAR CS6P-250(12) SOLAR EDGE OP 300 OPTOMIZERS(1) SOLAR EDGE # SE3000 A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37930	19041-20000-53194	5235 N WOODLAKE AVE	91367	3	171B093   394	2044024001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	01/02/2020 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.16494	-118.63222	NOTE: PERMIT FEES ARE $0 DUE TO AB 1414.PV1. INSTALL 18.60 KW DC PV SYSTEM WITH (60) MODULES, OPTIMIZERS AND (2) INVERTERS (SE7600)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37931	18041-20000-27273	2870 N BENEDICT CANYON DR	90210	5	156B153   181	4382007003	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.12276	-118.43482	PV1.  Install 13.115 kW roof mounted grid tied PV system.  (43) modules with 5.2 and 7.6 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37932	14041-10000-34645	608 S MATEO ST	90021	14	126A217   187	5164013013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.0376	-118.23251	NEW FIRE ALARM SYSTEM, ONE STORY, MIXED OCCUPANCY, SPRINKELERED BUILDING. 55 DEVICES AND ONE FA  PANEL AND 2 BOOSTER PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37933	17041-10000-11051	21700 W OXNARD ST SUITE 520	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.17901	-118.60179	Title 24 plan check.  T.I. to existing commercial office highrise.  One new subpanel with lighting and receptacle loads.  Total area = 3,510 sq. ft.     Building permit #17016-10000-05890	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37934	14041-10000-11045	555 W 5TH ST 32ND & 33R-D	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.05016	-118.25369	REMODEL MOST OF 32ND FL AND PART OF 33RD FLPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37935	18041-20000-00444	1008 S MAPLE AVE	90015	14	126A209   275	5145019003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.03788	-118.25423	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,218 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37936	15041-10000-18320	11600 W DUNSTAN		11	132B145   135	4401029008	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			06/12/2015 12:00:00 AM	05/21/2020 12:00:00 AM		Permit Finaled	12/03/2022 12:00:00 AM	PIN	34.05948723	-118.4676793	PC FOR POWER AND ENERGY. New  4-level, 54-unit  apartment complex over a 2-level subterranean parking structure. TOTAL AREA 30137 SQ FT.NOTE ORIGINAL APPROVED PLANS WERE MISPLACED AND NEW SETS OF PLANS WERE SUBMITTED ON 15041-100001-18320 PLAN CHECK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37937	10041-10000-25587	735 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	Remodel of existing retail mall.  Demolition of existing slabs, guardrail, escalators, elevator, interior and exterior finishes, signage.  New floor slab infills and associated structure.   New monumental stairs & escalators with canopy, new stairs, finishes, paving, signage, demising walls and temporary storefronts.   New exterior cladding.   New lower level stair & escalators.    New passenger, freight and service elevators, reconfigured egress stair.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37938	18041-20000-21794	5501 N FULTON AVE	91401	4	174B157  1151	2344015036	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.17033	-118.42277	PV1.  Install 8.05 kW DC roof mounted grid tied PV system.  (23) modules with power optimizers and 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37939	17041-20000-34744	15233 W VENTURA BLVD Suite 1309	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.1538	-118.46502	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,410 sq. ft.Note: Building application has been generated under 17016-20000-26154	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37940	19041-20000-49001	6745 N COZYCROFT AVE	91306	3	180B109    90	2148003004	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.19313	-118.582	PV1. INSTALL 11.055 KW DC GRIED-TIED PV SYSTEM WITH (33) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37941	17041-10000-01120	4551 S GLENCOE AVE Ste 120	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC for energy only to existing building. TI on fitness center inside of office building. Total areaa: 1610	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37942	13041-20000-05230	5670 W WILSHIRE BLVD 1st Floor	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			PC Approved	02/28/2013 12:00:00 AM	ADDRESS	34.06222	-118.35208	Change to lighting and circuits to an existing office space.  Load is 319 amps, if work is done on other floors, load may exceed 400 amps and Full plan check may be required.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37943	14041-20000-34411	13704 W VENTURA BLVD	91423	4	165B157   682	2266020009	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.1479	-118.43149	Plan check for energy only. CHANGE OF USE FROM ICE CREAM TO RESTAURANT. Adding new lights to existing lighting system - check for Title-24 compliance. 1,722sqft. New occup. is 62, emergency lighting is now required. Permit already issued under permit #14041-90000-32397	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37944	16041-10001-38982	1250 S WESTMORELAND AVE	90006	1	129B197   979	5076018023	R4-1XL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			07/23/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	34.0479	-118.2889	THIS IS PLAN CHECK ONLY FOR REVISION TO APPROVED PLAN, ALL CHANGES NOTED AS DELTA 4. SYSTEM SIZE NOW AT 2500A. PERMIT IS COVERED UNDER MASTER #16041-10000-38982<<<<PLAN CHECK FOR POWER AND TITLE 24.  NEW 7-STORY 93-UNIT SENIOR AFFORDABLE BUILDING.  SYSTEM INCLUDES NEW 3,000 AMP 208/120 VOLT SERVICE, EMERGENCY GENERATOR, AND FIRE PUMP.  TOTAL COMMON AREA = 52,040 SQ. FT.>>>>>(REF B# 16010-10000-05028)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37945	19041-20000-21928	10250 W CONSTELLATION BLVD 22nd Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Issued	06/18/2019 12:00:00 AM	ADDRESS	34.05735	-118.41746	PLAN CHECK FOR T24 OF COMMON AREA OF EXISTING HIGH RISE OFFICE 22ND FLOOR, ENERGY ONLY. LIGHTS AND OUTLET ONLY. TOTAL SQUARE FOOTAGE = 1,565 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37946	16041-20001-41322	1147 N VIA DE LA PAZ	90272	11	129B125   316	4422021005	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM	ADDRESS	34.05045	-118.52643	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on a SFD. Interconnect with a 200A. Derating the main to 175A. 10.88kW ungrounded system.  (34) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37947	16041-10000-27638	7050 N TOPANGA CANYON BLVD	91303	3	183B101   258	2138002038	(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.19875	-118.60563	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A NEW STARBUCKS COFFEE. 400 AMP SERVICE.TOTAL AREA 1822 SQ FT,B# 16016-10000-18203	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37948	17041-20000-34068	4421 N DENSMORE AVE	91436	5	165B141   120	2283014014	RE15-1-H	South Valley	Encino - Tarzana	Encino		1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.15145	-118.47774	Plan check for solar pv system, roof-mounted array on SFD.7.6kW ungrounded system. (29) 300W pv modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37949	18041-20000-44874	17019 W DEARBORN ST	91325	12	198B133   461	2692021025	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Closed	02/27/2020 12:00:00 AM	ADDRESS	34.23749	-118.50319	Plan check for a PV1 roof-mounted PV system. System size is 9 kWdc/8 kWac and consists of (25) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37950	19041-10000-16859	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	"FULL PC PWR AND ENERGY FOR T.I. AT SECOND FLOOR(FIRST TIME USE) OF (E) STORAGE ROOMS,  ""FARMERS MARKET"".  AREA OF SCOPE IS 3,100SF."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37951	12041-20000-17474	3200 N SAN FERNANDO ROAD bldg B	90065	13	153B209   457	5458002005	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	PIN	34.11584034	-118.25003258	Change of use from office to professional school (BUILDING B - EAST BLD).  Add subpanel, branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37952	14041-10000-24268	1655 W MANCHESTER AVE	90047	8	097-5A195 286	6034030041	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	33.96015	-118.30647	Outdoor energy plan check at parking lot area ; components including light pole, solar module and LED light.   The total area is 13560 SQ feet. Note. Variance is submited for this application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37953	12041-10001-04365	1043 S KINGSLEY DR	90006	10	129B193   528	5080025009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			09/19/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Expired	12/24/2014 12:00:00 AM	ADDRESS	34.05133	-118.30329	Revision to approved plans. Plan check for PV system point of connection and upgrade service to 600A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37954	18041-10000-11349	401 WORLD WAY	90045	11	090B161    37	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	33.94281	-118.40686	Plan check for Title 24  at LAX Parking Structure for parking level 4 and 5 Parking. Total area:  163,920 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37955	14041-20001-18316	4529 E BOWMAN BLVD	90032	14	141A231    58	5213029024	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM			PC Approved	07/09/2014 12:00:00 AM	ADDRESS	34.08204	-118.18517	Addittional information to change racking system.(((PV1.  Install 4.410 kW roof-mounted, utility-interactive PV system over detached garage.  Transformerless inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37956	13041-20000-27623	18855 W VICTORY BLVD	91335	3	180B121   391	2127001014	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.18675	-118.54436	POWER PLAN CHECK FOR UPGRADING AC UNITS IN RETIREMENT HOME	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37957	11041-10000-03510	6303 N OWENSMOUTH AVE Base & 1st-floors	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI IN AN EXISTING OFFICE. EPC IS FOR T24 & LIGHTING. (complete plan check may required by field inspector)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37958	18041-10000-19130	9510 S VERMONT AVE	90044	8	093A199    65	6039017075	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	03/04/2020 12:00:00 AM		Permit Finaled	07/28/2020 12:00:00 AM	ADDRESS	33.94986	-118.29139	Energy plan check for a retail store ; Scope includes new lighting and equipment with new area added. Total area is 12,203 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37959	17041-20000-41816	17261 W VANOWEN ST	91406	6	183B133   936	2230001012	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			Verifications in Progress	12/26/2017 12:00:00 AM	ADDRESS	34.19403	-118.50925	Plan check for a PV2 roof-mounted PV system. System size is 72 kWac and consists of (3) inverters, (240) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37960	18041-10000-28108	777 S SANTA FE AVE	90021	14	124-5A217 323	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM			PC Info Complete	07/26/2018 12:00:00 AM	ADDRESS	34.03354	-118.23024	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT OF OFFICE RESTAURANT SPACE. NEW LOADS < 200A, POWERED BY EXISTING PANELBOARDS, TOTAL AREA: 1,179 SQ.FTB# 18016-10000-22178	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37961	11041-20000-24993	1840 S CENTURY PARK EAST 18th floor	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM			PC Approved	12/05/2011 12:00:00 AM	ADDRESS	34.06188	-118.41473	Replacing 4 lights in the Vestibule (Corridor) area of the 18th floor.  No new lights are being added to the area. The four exsting lights are just being replaces.    The lights will be on 24 hours a day 7 days a week.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37962	18041-10001-13640	835 W JEFFERSON BLVD	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM			PC Approved	07/11/2018 12:00:00 AM	ADDRESS	34.02414	-118.28458	"PLANCHECK ONLY FOR CHANGES TO APPROVED SE. CHANGES UNDER DELTA 3 ONLY, TO REFLECT CHANGES  IN LAYONT, LIGHTS  AND CIRCUITS ON PANEL . FULL PLAN CHECK (POWER + ENERGY) FOR 1ST TIME TENANT (AND ALSO CHANGE OF OCCUPANCY) FROM ""RESTAURANT"" TO ""RETAIL"", FOR ABERCROMBIE & FITCH. INSTALL (1) 225A PANEL WITH ITS CIRCUITRY, TOTAL AREA: 2,736 SQ.FT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37963	15041-10000-43068	945 S HUDSON AVE	90019	4	132B185   486	5090006009	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Expired	01/24/2018 12:00:00 AM	ADDRESS	34.05779	-118.33477	pv1 sfd total system size 3kw ac using 2 central inverters. total of 26 modules. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37964	18041-20000-10457	3673 N BERRY DR	91604	2	162B173   923	2378025030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	PIN	34.13738075	-118.37867973	DOWNSIZE BREAKER FROM 200 AMP TO 175 AMP	N	N	Express Permit	06/10/2024 12:00:00 AM
37965	18041-10000-06107	21320 W DEERING CT	91304	3	189B105   167	2109001037	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Issued	02/20/2018 12:00:00 AM	ADDRESS	34.21583	-118.59659	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37966	17041-20001-23171	14040 N CAROL LANE	91342	7	228B141   523	2603026021	(Q)R1-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.31957	-118.48276	Expedite fee.  PV1.  Install 3.92 kW roof mounted grid tied PV system.  (14) modules with Enphase M250 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37967	17041-10000-16005	725 S FIGUEROA ST #1650	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC for energy.  T.I. to suite #1650, no change of use. office, connected load <400A, total lighting  area 3528 sq ft. B # 16016-10000-31110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37968	15041-20001-08527	6320 N TOPANGA CANYON BLVD G-1680	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for restamp of lost single line diagram.      Plan check for power and energy. Project scope is a first time tenant for one of the tenant spaces at the Topanga Canyon Westfield Mall. Project work included (1) 200-amp service, (2) 200-amp rated panels, and associated loads. Total lighting area = 3,934 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37969	17041-10000-08129	10250 W SANTA MONICA BLVD #1890	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR FIRST TIME TI ""CHAN LUU""  IN WESTFIELD CENTURY CITY. SUITE 1890"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37970	18041-10000-41668	1601 S PERRINO PL	90023	14	118-5A219  10	5169015014	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.02019	-118.2225	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37971	17041-20000-30248	6503 N COLDWATER CANYON AVE	91606	2	180B161   884	2326003011	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	34.18869	-118.41395	Plan check for Title 24 only. Project site is an existing daycare. Project scope is an addition of a play room/tenant improvement. Total lighting area = 395 sq. ft.Note: Building permit has been issued under 17014-30000-01340	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37972	15041-10000-27116	12460 W OSPREY LANE 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	PV2 ROOF MOUNTED. TOTAL SYSTEM SIZE 1.84 KW ON COMMERCIAL 4-STORY BUILDING (BUILDING 8 UNIT 22) UNIT TWO (8) MODULES: SUNPOWER MODULES SPR-230NE-BLK-D(1) INVERTER PVI3.0 OUTD-S-US-A (POWER ONE) 240VACZONING CLEARANCES FOR UNIT 1,2, AND 3 INCLUDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37973	16041-10000-05580	19755 W PARTHENIA ST	91324	12	195B117   209	2782024018	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Expired	03/19/2018 12:00:00 AM	ADDRESS	34.22836	-118.56402	PV1, rooftop solar installation 3.44kW AC system(16) HANWHA Q CellsQ-PRO(16) M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37974	17041-10000-19876	1881 N MORTON AVE	90026	13	142-5A211 164	5420025001	[Q]RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.08511	-118.24963	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE 3.8KVA - SYSTEM CONSIST OF 1 INVERTER(SOLAREDGE SE3800H-US) AND 13 MODULES(JINKO EAGLE MP 60B 280W).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
37975	19041-20001-02259	13323 W VENTURA BLVD	91423	4	165B157   792	2360011015	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	34.14688	-118.42332	SUPPLEMENTAL PLAN CHECK ONLY, CLARIFICATION OF SCOPE OF WORK, ADDITION OF NOTES. MINOR MODIFICATION TO LIGHTING CONTROLSPlan check for Title 24 only in existing space Tenant Improvement. Total area: 591 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37976	11041-20000-25254	19255 W VANOWEN ST	91335	3	183B117   946	2129014001	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1325.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.19397	-118.55298	CHANGE OF USE OF (E) 49' X 90' 1ST FLOOR MEDICAL OFFICE TO LAUNDRYMAT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37977	11041-20000-22273	1250 N TOWER GROVE DR	90210	5	144B157   145	4356026004	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM			PC Approved	01/03/2013 12:00:00 AM	ADDRESS	34.09352	-118.4241	PLAN CHECK FOR NEW 2-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE NEW 600A SERVICE SERVING MAIN HOUSE AND GUEST HOUSE . (EPC 1 0F 2)  Plan Check Only, Permit fees are under separate application per contractor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37978	16041-10000-25320	1420 S VERMONT AVE	90006	1	129B197  1362	5056001057	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.04562	-118.29142	Plan check for T-24 only. Remove HID fixtures and replace with new LED fixtures. Total affected area: 3,188 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37979	17041-10000-18809	808 S OLIVE ST	90014	14	127-5A209  65	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.04479	-118.25694	PC for energy only, Indoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 9,400 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37980	17041-20000-03511	5015 N VELOZ AVE	91356	3	171B121   542	2176013027	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.16147	-118.54071	Plan check for solar pv system, roof-mounted on SFD. Interconnect with a 200 MSP.Derating main breaker to 175A. 11.4kW ungrounded pv system. (44) 340W pv modules. Each module has a 400W power optimizer.Reduced permit fee of $30.13 due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37981	14041-10000-02293	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.15777	-118.43065	INSTALLATION OF NEW FIRE ALARM SYSTEM IN NOTRE DAME HIGH SCHOOL, TOTALING TO 20 DEVICES, 1 FACP. FIRE SPRINKLERED BUILDING CONSISTING OF BASEBALL STADIUM (6881 SQ FT) + ACUATIC CENTER (1946 SQ FT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37982	19041-10000-12662	11755 N EDDLESTON DR	91326	12	216B125   225	2870020027	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.28744	-118.53277	$0.00 FEE DUE TO SENATE BILL 1222 AND LB1414{eplan}Roof mounted solar system that includes 55 modules (longiSolar LR6-60PB 300w), 55 optimizers (SE P320) and 1 inverter (SE11400H-US). System size is 16.5 kWdc and 11.4kWdc.Main breaker de-rate to 175A shall be permitted separately under Express Permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
37983	17041-10003-40640	8500 W BEVERLY BLVD #117	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	Changes to an approved set of plans. All changes are clouded under delta 12.1. Changes include revising lighting floor plans, revising panel schedules, revising service load calculations, and revising Title 24 calculations.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
37984	14041-20000-14834	8375 N LAUREL CANYON BLVD	91352	6	192B165   307	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.22391	-118.39926	Intall new audible / vissual fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37985	15041-10000-12711	6626 N VALJEAN AVE	91406	6	180B141   319	2233029016	M1-1-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.19103	-118.48565	T24 ONLY.  REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXUTRES. TOTAL AREA 4800 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37986	16041-10000-22097	4814 W OAKWOOD AVE	90004	4	138B193   312	5522033017	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			06/23/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.07702	-118.31194	PC FOR  ENERGY AND POWER. New 3- story 11 units Type V-B Apartment over one story Type I-A garage. TOTAL COMMON AREA 10018 SQ FT.SERVICE 800 A. B #15010-30000-03290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37987	15041-10000-01470	11845 W OLYMPIC BLVD 505/510	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	PIN	34.03325831	-118.45191172	Plan check for T-24 only for T.I. Total area: 5201SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37988	19041-10000-15396	4607 S CENTRAL AVE	90011	9	112-5A209 246	5108025026	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2286.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.00154	-118.25674	Remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37989	19041-10000-26320	5720 S VERMONT AVE	90037	9	108B197  1354	5001013030	C2-1VL	South Los Angeles	South Los Angeles	Voices		2327.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	09/16/2020 12:00:00 AM		Issued	09/16/2020 12:00:00 AM	ADDRESS	33.98987	-118.29128	PC for T24 in a existing restaurant. Scope of work includes new lighting, controls, using exisitng lighting circuits. Total affected area is 2664 sqft both indoor and outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37990	13041-10001-15487	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.06725	-118.41704	PLANS MODIFIED. DELTA 1 CHANGES ONLY. MEDIUM VOLTAGE PVC CONDUIT ARE INDIRECT BURIAL, ORIGINAL APPROVAL, THESE CONDUITS WERE SUPPOSED TO ENCASED IN CONCRETE. THIS INSTALLATION OF THE CONDUITS IS ALLOWED PER NEC 300.50, PLANS REVIEWED BY NABIL AND PETER.PLAN CHECK ONLY. PERMIT TO BE PULLED UNDER ORIGINAL.PREVIOUS SUBMITTAL: Plan check for new medium voltage 4.6KV service, site medium voltage unit substation distribution, and equipment for existing country club. Site located in methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37991	18041-20000-06682	2220 N HYPERION AVE	90027	4	148-5A205 316	5432033017	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.10061	-118.2731	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37992	16041-20000-20303	1999 S AVENUE OF THE STARS 23th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check Title 24 only T.I. in existing space Morgan Stanley. Total area: 661 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37993	11041-20000-00531	17777 W VENTURA BLVD # 230	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	TI Unit # 230	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37994	17041-10000-21594	1541 W WILSHIRE BLVD 4th Fl-Suite 400	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.05529	-118.26949	PLAN CHECK FOR T-24 ONLY FOR TI-(OFFICE INPROVEMENTS ON 4TH FLOOR OF NON-HIGHRISE BUILDING). TOTAL AFFECTED AREA = 6246SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37995	16041-20000-04866	10939 W VENTURA BLVD	91604	2	162B173   393	2366022022	(Q)C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.14033	-118.36859	Plan check for energy only. T.I. to existing commercial nail salon.  Lighting (incl. emergency) and receptacles. 1,560 sq. ft.Permit pulled under application #15041-20000-06515.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37996	13041-10000-16639	14703 W RINALDI ST A-C	91340	7	213B149   125	2612015011	C2-1, P-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	34.28094	-118.45354	Retail unit in a shopping center to be subdivided into 3 separate retail spaces.  2 new unit panels.  Newly connected load < 400 A.  Addition of emergency lighting load, but no new lighting load overall - more than 50% of existing lighting to be relocated.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37997	15041-10000-15992	2144 W COLORADO BLVD	90041	14	162A223   132	5686003010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	05/26/2015 12:00:00 AM	ADDRESS	34.13893	-118.21341	REMODELED RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
37998	14041-10000-34556	5525 N CASE AVE	91601	2	174B173  1166	2350003006	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM			PC Info Complete	02/19/2016 12:00:00 AM	ADDRESS	34.17084	-118.37214	Plan check for power and energy. Project scope is a new 90-unit apt building. New 3000-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
37999	10041-10001-10463	604 S LINCOLN BLVD	90291	11	111B145   619	4243029024	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			PC Approved	05/03/2011 12:00:00 AM	ADDRESS	34.00013	-118.46491	Modification to approved plans.  PCIS# 10041-10000-10463.  Adding 8 new down lights and relocating 2 flourescent fixtures.  Title 24 plan check only.  <<<<<<<<<Ti in Smart & Final store. Plan check for T24 and Energy>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38000	17041-10000-44694	1030 N SWARTHMORE AVE STE 4-101A	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	Plan check for first time tenant General Porpoise power and energy. Total area: 526 sq ft.17016-10000-36552	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38001	13041-10000-30085	6238 N AURA AVE	91335	3	177B117   236	2131013010	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Expired	12/17/2015 12:00:00 AM	ADDRESS	34.18412	-118.55439	PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 16 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38002	19041-10000-38737	303 S LOMA DR	90017	1	133-5A207 207	5153007022	C2-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/07/2020 12:00:00 AM	ADDRESS	34.05979	-118.26586	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38003	14041-20000-17630	7341 W FOOTHILL BLVD	91042	7	202-5A199  94	2568010004	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.25075	-118.29184	TI to (E) commercial building for medical office tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38004	19041-10000-40806	5304 N VANALDEN AVE	91356	3	171B121   210	2163023003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.16722	-118.54988	Plan check for a PV1 7.6KW AC / 8KW DC roofmounted system with (1) inverter, (26) modules and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38005	18041-10001-28541	1315 W COLTON ST	90026	1	135A209   281	5160019003	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Info Complete	10/16/2019 12:00:00 AM	ADDRESS	34.06323	-118.257	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE ADDITION OF 4 SENSORS AND CHANGE OF METHAN SYSTEM TO LEVEL IV. __________________________________________INSTALLATION OF ONE LEVEL-V METHANE SYSTEM. (1) panel, (13) devices**REDUNDANT PLAN TO PLAN CHECK # 22041-10000-558241**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38006	17041-10000-10533	8718 N TILDEN AVE	91402	6	195B149   603	2638003005	R2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.22792	-118.44817	PV SYSTEM ROOF MOUNTED. 11 MODULES IN TOTAL AND CENTRAL INVERTER 3.8KW AC. THIS IS PART OF DUPLEX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38007	14041-20000-21470	11530 N MCLENNAN AVE	91344	12	213B133   562	2610006025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.28038	-118.50089	PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 11kW(1) SolarEdge S6000A-US-ZB-U transformerless inverter(1) SolarEdge S5000A-US-ZB-U transformerless inverter(51) Trina Solar #TSM-255PA05.18 pv modules(51) SolarEdge P300 power optimizersNote: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38008	16041-10000-04947	13371 N BRADLEY AVE	91342	7	225B145   176	2501002039	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	05/28/2016 12:00:00 AM	ADDRESS	34.31442	-118.47171	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.7KW INTERCONNECTED WITH MSP.(24) MONOX NEON 320WATTS(1) SUNNY BOY 7700TL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38009	17041-30001-08407	22855 W VICTORY BLVD	91307	12	180B097   327	2038040021	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			Verifications in Progress	06/21/2017 12:00:00 AM	ADDRESS	34.18859	-118.62711	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 312 kWac and consists of (13) inverters, (1404) modules, and (5) distribution panelboards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38010	16041-20000-29536	2005 S WESTWOOD BLVD	90025	5	129B153  1009	4323003014	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			PC Approved	08/19/2016 12:00:00 AM	ADDRESS	34.04641	-118.43411	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,756 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38011	17041-30000-37755	11828 W RUNNYMEDE ST	91605	2	186B169   615	2317017013	(Q)RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			10/19/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.20554	-118.39122	Plan check for new fire alarm sysem for appartment 26 units. Total fire alarm devices: 68 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38012	16041-10000-24201	2825 S VINEYARD AVE	90016	10	123B181  1428	5057009019	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Expired	08/16/2018 12:00:00 AM	ADDRESS	34.03048	-118.34513	PV1, rooftop solar installation on SFD, (1) PVI-3.0-OUTD,   (9) KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38013	18041-10000-33694	13600 W MARINA POINTE DR	90292	11	105B153   610	4229018052	C4(OX)-2D, [Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	03/02/2021 12:00:00 AM	ADDRESS	33.98473	-118.44411	T-24, ENERGY ONLY FOR EXTERIOR -TOTAL AFFECTED AREA 1012 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38014	15041-20000-36747	4025 N BENEDICT CANYON DR	91423	4	162B153   212	2272015007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.14282	-118.43319	Roof mounted solar system, 9.49 kW AC system(41) modules: LG310N1C-G4(41) microinverter: M250-60-2LL-S2X-IGStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38015	16041-20000-09536	8330 W FOOTHILL BLVD	91040	7	204B189    50	2560008001	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.25948	-118.31453	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to medical clinic and tenant improvement. Work includes a new 1,000-amp service, associated boards and loads, and a total lighting area of 47,719 sq. ft.Note: Building application has been created under 16016-20000-01436	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38016	16041-20002-05868	10000 W VALLEY SPRING LANE	91602	4	165B181   499	2424037016	A1-1XL-RIO, R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	06/01/2016 12:00:00 AM	ADDRESS	34.14541	-118.34832	"05-10-2016 Changes to approved set of plans, power plan check only. Changes include additional load to kitchen of equipment more than 400A per inspector, addditional panel ""MP"",  delta 1 only. (((((((Plan check Title 24 only T.I. in existing space  commercial kitchen (Private Golf Club). Total newly connected load less than 400A. Total area:  4,540 sq ft.))))))))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38017	18041-10000-39949	1001 S TOWNE AVE 105	90021	14	124-5A211 269	5132010049	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Issued	10/19/2018 12:00:00 AM	ADDRESS	34.03417	-118.24984	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY. Total sq. ft. 600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38018	14041-10000-14260	425 W 11TH ST	90015	14	127-5A207 254	5139008010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.04208	-118.26257	Core and shell only - office building renovation of an existing building (levels 1-5) with a new level (level 6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38019	19041-30000-15346	801 S FIGUEROA ST Suite 950	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is an existing suite on the 9th floor. Project scope is a tenant improvement. Total lighting area = 2,020 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38020	11041-10001-16499	3571 W WILSHIRE BLVD	90010	10	132B193    19	5503025013	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM			PC Approved	12/28/2011 12:00:00 AM	ADDRESS	34.06192	-118.3025	Revision to approved plans; revised fixture types and counts and add (2)  emergency fixtures (one for each restroom)T.I.  Existing retaurant in a single story building.  Remodel of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38021	16041-10000-45835	2644 E ROSEVIEW AVE	90065	1	145-5A217  90	5453003054	RD3-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			Reviewed by Supervisor	01/23/2017 12:00:00 AM	ADDRESS	34.09342	-118.22769	PV2, PC FOR PV ROOF MOUNTED SYSTEM IN AN APARTMENT BUILDING. SYSTEM SIZE 3KW (AC) CENTRAL INVERTER WITH 8 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38022	16041-10002-21088	400 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.04446	-118.25616	"Design changes to 16041-10000-21088 (E17LA02319), changes noted as Delta 5 & 6 which narrative is included as well as copy of master plan, and copy of approved landlord's plan for reference on service calculation.(1) Consolidated power source into one 800A Dist. Board(2) Revise voltage class from 120/240V to 120/208V(3) Revise seingle line diagram accordingly(4) Revise panel schedules accordingly(5) T24 calculation is also change due to total area change and few of luminaires change<<Restaurant remodel on existing commercial space. Change of use from nightclub/restaurant to a restaurant ""Shake Shack"". This is full plan check, total affected area: 2,767 sq.ft((B# 16016-40000-11947))>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38023	19041-20000-25186	7944 N PASO ROBLES AVE	91406	6	189B133   475	2204024003	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.21512	-118.50259	PV1. Install 5.27 kWDC, 4.81KWAC roof mounted grid tied PV system.  (17) modules with P320 OPTIMIZERS, (1) 5 KW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38024	16041-10000-27029	15059 W BAHAMA ST	91343	6	195B145   152	2651020027	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.233	-118.46045	PV1, INSTALL NEW 7.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (30) MODULES: HUNDSAI HIS-S260RG(BK) 260 W(30) MICRO INVERTERS: ENPHASE M215-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38025	15041-10000-28011	3760 N CAHUENGA BLVD	91604	4	162B177   443	2425001070	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.13637	-118.36226	Service upgrade to 600 amps, pc for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38026	13041-10000-21623	8834 W PICO BLVD	90035	5	132B169   933	4305014004	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.05477	-118.3846	(((Title 24 plan check per inspector request for express permit 13041-10000-19676.))) 08/12/2013T.I. ADD (31) LIGHT FIXTURES, (2) EXIT SIGNS. REPLACED (24) OUTLETS & COMPUTER, TELEPHONE, DATA CABLING. COMPLY W/ DEPT ORDER DATED 2/7/13. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. **INVESTIGATION FEE TO BE PAID THROUGH #13016-10000-03746** 2 OF 2 W/ #13042-10000-14323.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38027	13041-20000-05836	10724 W HOLMAN AVE 1-102	90024	5	132B153  1064	4325030005	[Q]RD1.5-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.05472	-118.43414	Install new panels in an existing 95-unit apartment building.  All new circuits in the interior of the units.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38028	10041-20000-25511	5767 W CENTURY BLVD 3rd FL	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	12/20/2011 12:00:00 AM	ADDRESS	33.94572	-118.38294	Plan check power and energy for TI on the 3rd floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38029	15041-20001-12120	21600 W OXNARD ST 19TH FLOOR	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Expired	06/15/2017 12:00:00 AM	ADDRESS	34.179	-118.6002	Changes to an approved set of plans. Changes include the reduction of the work space to 1,180 sq. ft. All changes have been reflected onto the Title 24 compliance forms. *****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NEWLY CONNECTED LOAD < 400 AMPS. 19TH FLOOR. 2784 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38030	18041-10000-31357	11111 W SANTA MONICA BLVD 20th FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK FOR T24 ONLY, RESTROOM & CORRIDOR REMODEL ON THE 20TH FLOOR OF AN OFFICE BUILDING. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-22436	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38031	16041-20000-12841	5525 W WILSHIRE BLVD	90036	4	135B181   896	5508011027	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.06249	-118.34902	Install a roof-mounted solar array on a Commercial building. Interconnect with a 400A service.System size: 48kW (4 - 12kW inverters). Ungrounded system. (170) 285W.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38032	11041-20000-22761	15424 W SUNSET BLVD	90272	11	129B125   501	4412001017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM			PC Approved	03/08/2012 12:00:00 AM	ADDRESS	34.04806	-118.52795	Gelson's Supermarket.  Remodel of the Deli area.  Adding and relocating light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38033	16041-20001-18010	17330 W SEPTO ST	91325	12	201B129    29	2734031017	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.25126	-118.51221	RSES expedited plan check fee per applicant request.  PV1.  Install 13 kW DC roof mounted PV system.  (50) 260 W modules with (1) 11.4 kW transformerless central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38034	17041-10000-33729	1015 N ALEXANDRIA AVE	90029	13	144B197  1077	5538003003	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.08896	-118.298	Install new rooftop solar on a SFD, 5.223 kW DC  with (1) inverter (19) modules with (19) power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38035	18041-10001-03559	6221 W 96TH ST	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	33.94902	-118.39331	Plan check for a lost plan. Permit shall be under original application.(((PC for T24 only for new outdoor fixtures. Installing new lights in parking lot of LAX. Installing three new panels, 37.5kVA transformer, lights and receptacles, equipment. 70000sqft. B#17026-10001-00441))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38036	12041-20001-08340	14630 W PLUMMER ST	91402	7	198B149    69	2650026900	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.2424	-118.45147	(variance has been filed to treat the kitchen as a residential kithcen use. GFCI only required counter top. Dedicated equipment in garage areas. Inspector to verify requirement of GFCI per field conditions. )REVISIONS TO AN APPROVED SET OF PLANS. REVISIONS NOTED DELTA SIX.  NEW EMERGENCY GENERATOR, NEW BRANCH CIRCUITS, NEW FEEDERS AND OCPD. PLAN CHECK FOR POWER.  PLAN CHECK POWER AND ENERGY FOR NEW TWO STORY LAFD FIRE STATION. NEW 800 A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38037	17041-10000-14258	1114 E 8TH ST	90021	14	124-5A213 367	5146019007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Info Complete	06/13/2017 12:00:00 AM	ADDRESS	34.03501	-118.24516	PC FOR SERVICE UPGRADE TO EXISTING BUILDING. RECONNECT EXISTING PANELS AND PROVIDING NEW PANELS FOR FUTURE TENANTS. SERVICE LOCATED IN METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38038	14041-10001-08302	4701 N NATICK AVE	91403	4	168A149    31	2265002023	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Apartment			03/24/2015 12:00:00 AM			PC Approved	03/24/2015 12:00:00 AM	ADDRESS	34.15619	-118.45437	Plan check fee is $0.00 due to Senate Bill 1222.Change to approved set by removing (1) 31.6A IG Plus A Fronious inverter, and (44) modules from the system.((($0 permit fee is due to Senate Bill SB-1222.  PV2.  Roof mounted PV system with size 97.295 KWdc.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38039	15041-10000-05869	420 S GRAND AVE	90013	14	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	PIN	34.05085086	-118.2528414	ADDING SURGE ARRESTORS (5KV) TO AN EXISTING SERVICE 4160 VOLTS.  PLAN CHECK FOR MEDIUM VOLTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38040	16041-20000-34447	2358 N KIMRIDGE ROAD	90210	4	153B165   285	4388011041	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.11478	-118.39983	Plan check for installation of PV system on SFD, roof-mounted. Interconnect with 400A MSP.7.6kW ungrounded system. (22) 295W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38041	19041-20000-24605	1623 S CREST DR	90035	5	129B169   687	4305010014	R1V2	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.05011	-118.38764	install (1) tesla ESS rated 5KW to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38042	18041-20000-39861	801 S FIGUEROA ST Lobby	90017	14	129A207   107	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Issued	01/25/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only for T.I. in existing space lobby common area. Total area: 4255 sq ft. B#18016-10000-15002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38043	11041-10000-17603	108 N ROBERTSON BLVD	90048	5	138B169   337	4334002026	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.07561	-118.38359	Fire alarm system for retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38044	18041-10000-14573	7833 W SUNSET BLVD	90046	4	147B177   967	5551020020	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.09823	-118.36022	PC FOR BANK TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 18036  SQ.FT  169 UNITSINDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38045	13041-10000-19276	600 W WILSHIRE BLVD 1100B	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	34.04796	-118.25622	PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. TENANT IMPROVEMENT OF EXISTING OFFICE SPACE. PLAN CHECK FOR TITLE 24 ONLY.  2327 SQFT. HIGH RISE BUILDING. EMERGENCY LIGHTING INCLUDED. 17 FLOORS: WORK ON FLOOR 1100B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38046	17041-10000-36241	1640 N CORONADO ST	90026	13	142-5A207  57	5423012033	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.08643	-118.26369	INTERIOR ALTERATIONSREPLACE HID WITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38047	16041-20000-14662	16701 W STAGG ST	91406	6	189B137    58	2205009027	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.21334	-118.49716	Plan check for a PV2 roof-mounted PV Feed-In Tariff system. System size is 45 kWac and consists of (3) inverters, (195) modules, (1) load center, and (1) transformer.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38048	17041-10001-15490	1429 S WESTWOOD BLVD	90024	5	132B153   916	4324010009	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.05467	-118.44147	PC FOR T24 ENERGY ONLY. PERMIT FOR TI TO OFFICE SPACE. NEW LIGHTING. PART OF PERMIT COVERED UNDER MASTER. REMAINDER TO BE ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38049	19041-10000-39037	20059 W RINALDI ST	91326	12	213B113   482	2701100005	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.2756	-118.57118	PC FOR A NEW FIRE ALARM SYSTEM IN A MOVIE THEATER. SCOPE OF WORK INCLUDES ONE NEW FIRE ALARM PANEL, ONE NEW COMMINUICATION PANEL, AND 130 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38050	13041-10000-14560	2049 S CENTURY PARK EAST STE 2750	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	pc for energy only. hirise suite 2750.OFFICE TI OF EXISTING TENANT SPACE; NO CHANGE IN USE; EXISTING 'B' OCUPANCY TO REMAIN; SCOPE OF WORK  +/- 5534 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38051	10041-10000-09584	1324 S NORMANDIE AVE	90006	1	129B197  1144	5075009021	C2-1VL, [Q]R4-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.04644	-118.30011	CONSTRUCTION OF NEW  57,000 SQ.FT.  TWO-STORY, TYPE VA  COMMUNITY BUILDING WITH MIXED OCCUPANCY CLASSIFICATION (B,A-3, A-2, E, S).  RELATED SITE WORK INCLUDES PAVING,  STORM DRAIN AND UTILITIES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38052	17041-10000-44844	500 WORLD WAY T.I.	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	Energy plan check for office T.I. Scope includes new lighting and equipment. Total area is 3,526 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38053	11041-10001-02065	3833 S CRENSHAW BLVD	90008	10	117B185   719	5045019900	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.0162	-118.33546	Revise location of main entrance door including  (1) exit sign and (2) receptacle outlets.(ADD 1416 SF   2ND FLR ADDITION AND TI FOR ADULT EDUCATION.  plan check for power and energy.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38054	15041-10000-31899	3755 S SAWTELLE BLVD BLDG A	90066	11	114B157   145	4234003033	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.01202	-118.42043	T-24 TO FIRST FLOOR RETAIL SPACE, NEW 3 STORY MIX USED BUILDING. SECOND AND THIRD FLOOR CONSIST OF RESIDENTIAL. NEW 400AMP SERVICE. PLAN CHECK FOR ENERGY ONLY. 2008 T-24 ENERGY CODE TOTAL SQ. FT. 685.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38055	16041-10000-44955	9315-9317 W PICO BLVD	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.05542	-118.39328	PC FOR PV2 COMMERCIAL ROOFTOP SOLAR. SYSTEM SIZE IS 20KA AC USING CENTRAL INVERTER SYSTEM WITH TOTAL OF 43 MODULES AND POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38056	18041-30000-39029	10635 W SANTA MONICA BLVD 200	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Issued	10/11/2018 12:00:00 AM	ADDRESS	34.05353	-118.43031	PC FOR NEW FIRE ALARM ON THE 2ND FLOOR. SCOPE INCLUDES NEW 27 DEVICES RPS IS EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38057	18041-10000-24928	2201 E TROJAN WAY	90033	14	135A225   143	5202001011	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.06467	-118.2022	New 4-story, 200 room, Student Housing Building over 1-level subterranean Parking. FULL PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT #18010-10000-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38058	11041-10002-22455	3900 N STANSBURY AVE	91423	5	162B153   353	2274027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	Public Safety Only			06/14/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.14084	-118.44264	REVISIONS TO PERMITTED SET OF PLANS: ADDITION OF 21 FA DEVICESFire alarm for a private school.  77 new fire alarm devices to be installed and one new panel. ((((additionof 10 devices to existing approved set  3-1-12)))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38059	12041-10000-19204	8556 W FOOTHILL BLVD	91040	2	204B189    26	2560004026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.25957	-118.31982	Plan check T24 Energy/Emergency lighting for existing interior lobby remodel for auto service.  (((Load is less than 400A per contractor, Permit fees are under Inspection.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38060	15041-20001-12937	23032 W CALVERT ST	91367	3	177B097   395	2039008029	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM			PC Approved	05/05/2015 12:00:00 AM	ADDRESS	34.18046	-118.62887	Change to approved set of plan. Change the layout of the modules and micro-inverter manufacturer{{{{{{{Plan check for a PV1 roof-mounted PV system. System size is 5.3 kWac and consists of (17) micro-inverters and (17) modules. Standard plan is not being used.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38061	17041-10000-05174	9422 S WILMINGTON AVE	90002	15	094-5A215 337	6046001004	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	33.95104	-118.23843	Plan check for PV1 roof mounted system. System size is 3.0kWac with 15 modules, 15 optimizers, and 1 3.0kWac inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38062	15041-20000-21845	6924 N BALCOM AVE	91335	3	183B129   727	2122003023	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.1963	-118.52049	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel. (16) Solarworld SW 285 Mono Modules(16) Enphase M240 Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38063	11041-10000-15991	8475 N SUNLAND BLVD	91352	6	192B177   243	2408014029	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.22451	-118.36586	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing light fixtures with LED light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38064	19041-30000-48274	12751 W MILLENNIUM	90094	11	102B161  1235	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Issued	03/06/2020 12:00:00 AM	ADDRESS	33.9761	-118.41651	Energy Plan check only, area of scope (1648)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38065	14041-10000-22217	707 E 7TH ST	90021	14	126A213   190	5147027001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.03975	-118.24512	Title 24 plan check only.  Total area = 19,768 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38066	15041-20000-01176	539 S MAPLETON DR	90024	5	138B157   126	4359013038	RE40-1	West Los Angeles	Westwood	Bel Air - Beverly Crest, Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.07466	-118.42924	NO PERMIT TO BE ISSUED UNDER THIS APPLICATION. ALL PERMIT FEES COLLECTED UNDER BUILDING PERMITREMODEL/ ADDITION OF SFD. ALL NEW ELECTRICAL EQUIPMENT. PC FOR POWER ONLY. NEW SERVICE AND FLOOR PLAN WIRING. NEW 600A @208V SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38067	13041-10000-06804	6900 W BONITA TER	90068	4	150B181   562	5549017006	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			03/15/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.10467	-118.34034	NEW 4 STORY, 16 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38068	17041-10000-30173	6550 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.18956	-118.60562	Plan check for Title 24 only in existing retail store T.I. Total area: 527 sq ft. Note Building Applicaiton# 17016-10000-24457	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38069	17041-20000-46133	801 S MATEO ST	90021	14	124-5A217 333	5166017004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.03345	-118.23242	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL "" JUICE "".  2975 SQFT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38070	19041-10000-13601	12203 W MOORPARK ST	91604	2	165B165   349	2364003046	[Q]R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			04/15/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.15056	-118.39892	PLAN CHECK FOR A NEW FIRE ALARM IN A 16 UNITS APPARTMENT COMPLEX. SCOPE INCLUDES NEW 1 FACP, 1 POWER SUPPLY AND 1 ANNUNCIATOR WITH 71 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38071	19041-20000-53120	110 E 9TH ST 2ND FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Info Complete	12/23/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN (E) SPACE. TOTAL SQ. FT. 3428	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38072	12041-20000-00955	3669 S WHITTIER BLVD	90023	14	121-5A229  71	5188008027	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	PIN	34.02498217	-118.19373354	New coin operated laundry	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38073	13041-10000-03955	4401 W SUNSET BLVD	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.09708	-118.28526	PLAN CHECK OUTDOOR LIGHTING AND POWER IMPROVEMENTS FOR CHURCH OF SCIENTOLOGY EXISTING FILM STUDIO.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38074	18041-20000-22208	15821 W VENTURA BLVD suite 450-445	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Issued	06/14/2018 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for Title 24 Energy only in existing space T.I office new lighting and use existing circuits. Total area: 2957 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38075	17041-10000-32343	633 W 5TH ST 54TH FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for T24 only, TI to existing commercial kitchen on  54th fllor 2576 SQ FT of the total floor area; Install (1) new 100A panel, other panels are existng for the area, just added few circuitry.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38076	14041-20001-26488	160 S JUNE ST	90004	4	138B185   379	5515002007	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM			PC Approved	10/17/2014 12:00:00 AM	ADDRESS	34.07199	-118.33462	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with 400A MSP (split service panel, two 200A main breakers). System size: 7.955kW.(37) EnPhase M215-IG microinverters(37) SolarWorld SW270MONO BLK pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38077	15041-10000-01361	200 WORLD WAY TERM 2-ARRV  LEV1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2ARRV  LEV 1  SPACE 282PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38078	17041-10000-22598	535 W EL SEGUNDO BLVD	90248	15	081B201   247	6132002027	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Apartment			07/06/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.91658	-118.284	PC FOR FA IN AN APRARTMENT BUILDING. 7 PANELS AND 207 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38079	19041-20000-14515	9937 N SHIRLEY AVE	91324	12	201B117    16	2726013009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.25111	-118.55925	PLAN CHECK FOR INSTALLATION OF A PV SYSTEM WITH ESS ON EXISTING SFD. SYSTEM SIZE IS 7.68KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (24) PV MODULES WITH SOLAR EDGE P320 POWER OPTIMIZERS, A SE7600 INVERTER WITH A 5KW AUTO TRANSFORMER, 125A ESSENTIAL LOAD CENTER, AND (2) 9.8KWH TESLA POWERWALL BATTERIES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38080	16041-20001-30267	9280 W NIGHTINGALE DR	90069	4	150B169  1384	5561007023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.10343	-118.39095	8/14/2018changes to an approved set of plans.  changes to inverter rating 15KW AC SMA  and new transformer.plan check for power. (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 30KW INTERCONNECTED WITH MSP.Note: $0.00 permit fees due to Senate Bill 1222)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38081	16041-10000-22348	4111 W VENICE BLVD	90019	10	126B189   158	5072007022	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.04433	-118.3268	Title 24 plan check only.  Total area = 2,215 sq. ft.T.I. to existing market.  Convert to 7-11 store.  New lighting and receptacles (new load < 400 A).  Panels to remain existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38082	10041-10001-10459	189 S THE GROVE DR F7a & F7b	90036	10, 4	138B177  1132	5512003042	(T)C2-2D-O, MR1-1VL	Central, South Los Angeles	West Adams - Baldwin Hills - Leimert, Wilshire	Mid City West, West Adams		2145.01, 2201.00	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM			PC Approved	11/29/2010 12:00:00 AM	ADDRESS	34.07125	-118.35662	revisions to approved set of plans in suite #'s F7A & F7B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38083	14041-10000-32401	9027 N CANOGA AVE STE # N	91304	3	195B105    39	2779018036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.23429	-118.59779	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH  NEW LED FIXTURES. TOTAL AREA 1048SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38084	12041-10000-06935	7651 N LAUREL CANYON BLVD	91605	6	186B165    52	2307013001	(T)(Q)R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	Public Safety Only			03/27/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.20996	-118.39692	NEW FIRE WARNING SYSTEM FOR 3-STORIES APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38085	08041-20001-00578	8701 N SAN FERNANDO ROAD	91352	6	195B169   525	2631034010	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM			PC Approved	07/12/2011 12:00:00 AM	ADDRESS	34.22749	-118.38141	Revision to the approved plan. All the changes are shown with delta #.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38086	15041-10000-01438	10990 W ROCHESTER AVE	90024	5	132B153   861	4324007101	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.05528	-118.44523	Addition of fire alarm supervisory system for elevator upgrade project.  12 devices + 1 new panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38087	19041-20000-22579	4328 W MELROSE AVE	90029	13	141B197   505	5538030019	C2-1	Central	Wilshire	East Hollywood		1926.10	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	34.08344	-118.29506	Plan check for Title 24 only in existing space Tenant improvement. Total area: 1,284 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38088	17041-20000-43644	12701 W HORTENSE ST	91604	2	168B161   712	2362022016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.15501	-118.40964	Plan check for solar pv system w/roof-mounted array on SFD.8.4kW ungrounded system.(30) 360W pv modules.(30) EnPhase IQ6-Plus-72 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38089	12041-10000-19389	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check power and energy for Fox Building 100 3rd floor office TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38090	15041-20000-39758	3658 S RUTHELEN ST	90018	8	120B193  1517	5042017028	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Expired	12/28/2017 12:00:00 AM	ADDRESS	34.02148	-118.31266	PV1. NEW SOLAR SYSTEM ON EXISTING ROOF-TOP. TOTAL SYSTEM SIZE IS 2.5KWac. (10)MODULES-BOVIET 260W(1)INVERTER-FRONIUS GALVO 2.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38091	18041-10000-40431	919 S ALBANY ST	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Approved	11/05/2018 12:00:00 AM	ADDRESS	34.04913	-118.27045	RENOVATION OF EXISTING ROOMS FOR NEW LIGHTING, CONTROLS, POWER AND DATA OUTLETS.TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38092	19041-20000-27912	3501 E EMERY ST	90023	14	117A225   289	5192008005	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM			Reviewed by Supervisor	07/31/2019 12:00:00 AM	ADDRESS	34.01434	-118.20238	change of use from manufacturing to indoor nursery 600 amp service upgrade with TI.plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38093	16041-20000-13266	10452 N RAINTREE LANE	91326	12	207B121   739	2728031059	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.26107	-118.54283	$0 permit fee is due to State Senate Bill SB 1222. PV1.  Install 18.285 kW DC roof-mounted PV system.  (53) 345 W PV AC modules - SPR-X21-345-C-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38094	19041-10001-06996	7525 N TOPANGA CANYON BLVD	91303	3	186B101   309	2023002001	[Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM			PC Info Complete	07/09/2019 12:00:00 AM	ADDRESS	34.20725	-118.60619	CHANGE TO AN APPROVED SET, T-24 ONLY, CHANGE UNDER DELTA 2, CHANGE INCLUDE CHANGING FIXTURE IN THE CONFERENCE RM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38095	13041-10000-33753	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			Reviewed by Supervisor	12/16/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	"Plan check for T24 for tom bradley LAX project.Conduit stops for (5) future tenants from (E) 1600A, 120/208V, 3PH, 4W distribution board ""TSWB1"". Emergency lighting is in scope of work. Projected area for lighting work is approximately 8750 sq ft. (Phat liu)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38096	12041-10000-02476	17719 W CHATSWORTH ST	91344	12	207B129   379	2712029019	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.2651	-118.52048	T.I. to an existng office building, with jewelry showroom.  Lighting change, new circuits and receptacles.  PLAN CHECK is ONLY for Energy, with Emergency lighting.  PERMIT IS FOR 4-NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38097	16041-10000-36148	947 S HOOVER ST	90006	1	130-5A201  12	5076006026	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.05376	-118.28439	TITLE 24 ONLY FOR EXISTING COMMERCIAL BUILDING. REMOVAL OF HID FIXTURES AND REPACING WITH NEW LED FIXTURES. TOTAL SQ. FT. 40650	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38098	15041-10000-20415	9562 N WOODMAN AVE	91331	6	201B149   684	2644019024	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.24437	-118.44619	PV1, INSTALL 4.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(16) MODULES: KYOCERA KU2656ZPA(1) INVERTER:SOLAREDGE SE3000A-US-ZB	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38099	19041-20000-13071	18663 W VENTURA BLVD Suite 112	91356	3	174B121   564	2160006038	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.17067	-118.54022	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area =1,312 sq. ft.Note: Building application has been generated under 18016-10000-14006	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38100	19041-10000-14089	1663 S BUTLER AVE	90025	11	126B149   269	4261012903	[Q]PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.04385	-118.45078	Replace fluorescent troffers with new LED retrofit kits (1st and 2nd floor) - Indoor only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38101	14041-10000-21238	2440 N HIDALGO AVE	90039	13	148-5A209 286	5440014023	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Apartment			08/06/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.10117	-118.25625	PV1 5.355KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE5000A-US}]. [(21)modules: {Trina {TSM-255PC05.18}}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38102	13041-10000-30903	9513 N JELLICO AVE	91325	12	201B129   429	2755005004	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	01/03/2014 12:00:00 AM	ADDRESS	34.24382	-118.51897	plan check only. plan abandoned due to system change - see 14041-10000-06891.PV1.  Install 14.9 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverters: Enphase M215.  64 modules: Solar World SW270 MONO 270W.  Panel upgrade from 100A to 200A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38103	19041-20000-29830	8354 N FAUST AVE pv1	91304	12	192B097   323	2004004026	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.22114	-118.62017	pv1instll roof mounted pv system sized 9.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38104	19041-30000-09759	426 S ROBERTSON BLVD	90048	5	138B169   805	4334015037	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.07142	-118.38361	Plan check for a fire alarm system 6-story, 37-unit apartment building. System consists of (1) FACP and (115) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38105	19041-20000-08046	2570 N BENEDICT CANYON DR pv1	90210	5	153B153    20	4382007011	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.11927	-118.43575	pv1install roof mounted pv system sized 5KW AC interconnetced with an existing pv system for a total rating of 10KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38106	14041-10000-19076	1936 S SELBY AVE	90025	5	129B157   763	4321010032	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			07/16/2014 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.04888	-118.43182	Plan check for power and energy.  No title 24 forms submitted.  Building application submitted before title 24 part 6 code effective date.  New service, pannelboards, lighting, recepticles in new 4 story 8 unit apartment building.  Fees for total area to be verified by plan check engineer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38107	18041-10000-18425			6	183B149   473	2217010045	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM			Verifications in Progress	05/22/2019 12:00:00 AM	PIN	34.19628868	-118.44604173	PC FOR NEW 2-STORY MIDDLE SCHOOL WITH 16 CLASS ROOMS. SCOPE INCLUDES NEW SERVICE, PANELS, TRANSFORMER, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 90540 SQ.FT. B#17010-10000-04639	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38108	13041-20000-11496	7203-7219 N VAN NUYS BLVD	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.20159	-118.44895	OUT DOOR LIGHTING FOR BUILDINGS. LOCATION IS PERMITER OF PARKING LOT BUT LIGHTING IS USED FOR SIDES OF BUILDINGS. COVERS ADDRESS RANGE 7203-7219. TOTAL AREA COVERED 1840 SQ FT. PC FOR ENERGY ONLY. OUT DOOR LIGHTING. PERMIT FOR CIRCUIT TO BE ISSUED FROM THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38109	11041-10000-08271	404 S FIGUEROA ST LOBBY	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.05326	-118.25596	SMALL SPACE IN THE LOBBY OF THE HOTEL CONVERTED TO OFFICES FOR FEDEXPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38110	19041-20000-30757	10210 N ENCINO AVE	91325	12	204B129   251	2734026005	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.25597	-118.5153	PV1.  Install 12.60 kW DC / 11.50 kW AC roof mounted grid tied PV system.  (42) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38111	14041-10006-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	Change to approved set by adding new (PANELS), CIRCUITS and lighting on the floor plan. All changes are under delta-25 Package-3 only.RELATED PLAN APPLICATIONS 16041-10006-15547 (SINGLE LINE DIAGRAM, LOAD CALCULATIONS & T-24)14041-10005-28878 (EQUIPMENT, LAYOUT, & T-24)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38112	18041-10001-46956	663 N RADCLIFFE AVE	90272	11	126B125   384	4412014038	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM			PC Approved	03/27/2019 12:00:00 AM	ADDRESS	34.04279	-118.5308	PC only for an aapproved set. scope includes upgrade circuit breaker to 125A and relocating 30A feeding AC unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38113	16041-10000-42908	17051 W JERSEY ST	91344	12	207B133    34	2696022022	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/28/2017 12:00:00 AM	ADDRESS	34.26773	-118.50403	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.16KWac.(13)AC MODULES-SPR-E20-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38114	16041-10000-45155	9223 N OWENSMOUTH AVE	91311	12	198B105   134	2746012039	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.238	-118.60204	PC FOR POWER :  NEW 2500A SERVICE , 2500A SWBD AND  ADDING ONE 225 KVA TRANSFORMERTO SUPPLY EXISTING 600A DIST BOARD WITH LOADS.Note that for original 2000A SERVICE , Isc was 30KA; service equipment is rated at 65KAIC	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38115	16041-10000-04366	3590 S OCEAN VIEW AVE	90066	11	114B153   624	4248024007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM			Corrections Issued	02/08/2016 12:00:00 AM	ADDRESS	34.00888	-118.43577	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (27) MODULES AND (2) 3.0KW INVERTERS WITH A (150AMP) LOAD CENTER. TOTAL SIZE IS 6.0 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38116	13041-10001-27878	11269 W ACAMA ST	91602	2	165B173   763	2366016011	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.14658	-118.37702	EXPEDITED PER APPLICANTS REQUESTPV1 4.75KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE5000A-US}]. [(19)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38117	14041-10000-10519	1000 W OLYMPIC BLVD	90015	9	127-5A205 520	5138007084	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.04578	-118.26734	T.I. for existing theater.  Plan check is for power only.  Installation of 4DX motion chairs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38118	16041-10000-22110	18433 W ROSCOE BLVD 210	91325	12	192B125   578	2786022035	QC1-1VL, QP-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.22091	-118.53469	PC FOR T24 ENERGY ONLY. MEDICAL OFFICE WITH NO WORK IN PATIENT ROOMS. ONLY BUSINESS AREAS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38119	19041-20000-25028	4042 W FARMOUTH DR	90027	4	154-5A201  79	5592015014	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.11793	-118.28235	Plan check for a PV1 roof-mounted PV system. System size is 12.285 kWdc/11.978 kWac-CEC and consists of (2) inverters, (39) modules, (2) load centers, and (2) battery back-up units.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38120	14041-10000-19093	1353 S ABBOT KINNEY BLVD	90291	11	108B145  1282	4239027013	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM			PC Approved	07/16/2014 12:00:00 AM	ADDRESS	33.99081	-118.46612	PLANCHECK FOR T24 ENERGY.  T.I. to existing retail space . NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS. 1437 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38121	15041-20001-11898	12446 W OSPREY LANE Unit 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	33.97949	-118.41001	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (8) modules, and (1) inverter. This is Unit 2 of 3.Note: PV solar clearance shall apply to the three units under this PCAM number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38122	19041-20000-24245	10528 W LAURISTON AVE pv1	90064	5	129B157   938	4315002003	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.04797	-118.42214	pv1install roof mounted pv system sized 5.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38123	14041-10000-05555	3150 W WILSHIRE BLVD # 112	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	PLANCHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR STARBUCKS. HIGHRISE. SUITE A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38124	13041-20000-34030	7640 N TAMPA AVE UNIT B	91335	3	186B117    83	2104012066	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.20967	-118.55333	CHANGE OF USE FROM RETAIL TO MEDICAL BUILDING. PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38125	13041-20001-35625	4937 N TOPEKA DR	91356	3	168B121    69	2176008003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.16032	-118.54767	((EXPEDITE FEES))))PC FOR PV1 SINGLE FAMILY DWELLING. THIS IS PLAN CHECK FOR THE ROOF MOUNTED PART OF THE PV SYSTEM. ROOF MOUNTED 6KW AND SERVICE INTERCONNECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38126	19041-30000-47570	4749 W ELMWOOD AVE	90004	4	138B193    25	5522019003	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	10/30/2021 12:00:00 AM	ADDRESS	34.07843	-118.31079	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS 64 DEVICES WITH A NEW FIRE ALARM CONTROL PANEL AND A NEW POWER SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38127	16041-10000-16776	19559 W SHADOW RIDGE WAY	91326	12	217-5A117 145	2701021006	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Issued	05/12/2016 12:00:00 AM	ADDRESS	34.29064	-118.55979	PV1, rooftop solar installation 8kW DC, (32) Enphase M250,  (32) SW275	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38128	14041-10000-13881	4270 N PERLITA AVE	90039	13	159B205   754	5594010018	(Q)RD2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.13119	-118.26817	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38129	14041-20000-03901	6020 N CANOGA AVE #103	91367	3	177B105   119	2149005051	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.1801	-118.59721	TI energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38130	13041-10001-16329	501 WORLD WAY	90045	11	090B165   128	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	33.94297	-118.40516	PLAN CHECK ONLY. plan check fees on original application.SUPPLEMENTAL PC FOR T24 ENERGY ONLY.  TI  LIGHTING FOR THE ATTACHED PARKING BUILDING ADDED TO THE SCOPE. 200,000 SQFT, EMERGENCY LIGHTING.SUBMITAL-2 WAS CHARGED FOR OUTDOOR THAT WAS NOT ACCOUNTED FOR DURING SUBMITAL-1 FOR AREA OF 3556 SQ FT ON THIS APPLICATION.UNDER ORIGINAL PC:  PLAN CHECK FOR TITLE 24 PART 6 ENERGY. SINGLE TOWER AT LAX. SCOPE OF WORK < 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38131	18041-20000-42001	5142 N STROHM AVE	91601	4	171B177   765	2419021011	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.16425	-118.3592	Plan check for PV roof mounted system installed in to existing system, install 2 new inverters(6.0kW) with 20 new PV modules, addtion of PV system size: 6.0kW DC, 5.403KW AC CEC, Total system size: 11.46kW AC CEC, 12.0kW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38132	17041-20001-46498												Electrical	Electrical	Apartment			12/28/2017 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM				expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38133	17041-20000-05566	16047 W LONDELIUS ST	91343	12	195B141   602	2672025018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.22948	-118.48209	PV1.  Install 8.505 kW roof mounted grid tied PV system.  (27) modules with (2) 5.2 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38134	18041-20001-45028	24221 S STERLING RANCH ROAD	91304	12	192B089   181	2017038013	RE11-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.21965	-118.65481	change of address	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38135	10041-10000-20542	3525 E EMERY ST	90023	14	117A225   300	5192008013	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM	12/06/2010 12:00:00 AM		Permit Finaled	03/14/2011 12:00:00 AM	ADDRESS	34.01427	-118.20201	TI IN AN EXISTING COMMERCIAL AREA (WAREHOUSE & OFFICES) DUE TO FIRE DAMAGE. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38136	17041-10000-20993	120 W FLORENCE AVE	90003	9	102B201   871	6031001900	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	33.97452	-118.27479	Replace fire alarm control panel.  All other devices to remain existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38137	19041-10000-46111	8555 N SPARTON AVE	91331	6	192B157   259	2637011003	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	12/14/2019 12:00:00 AM	ADDRESS	34.22521	-118.42877	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 12  (Q CELLS Q. PEAK DUO BLK-G6 335) MODULES, 12  (SOLAR EDGE P370) POWER OPTIMIZERS, 1 (SOLAREDGE SE 3000H-US) INVERTER, CONNECTED TO AN EXISITING 200A  MAIN SERVICE PANEL. SYSTEM SIZE IS 4.44KW DC & 3.00KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38138	12041-10000-17182	10128 W HOLLOW GLEN CIR	90077	5	156B153   152	4382025***	RE15-1-H-RPD	South Valley, West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.12309	-118.44225	Plan check for solar. Single family dwelling. 10.56 kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38139	19041-20001-39299	11357 W HENDLEY DR	91604	2	162B173   803	2378018031	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM			PC Approved	11/15/2019 12:00:00 AM	PIN	34.13841903	-118.37686718	11-15-2019 Changes to an approved set of plan, Changes include revise drawing to show new main panel  225A Buss with 200A Main circuit breaker.Fess $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38140	11041-10000-05159	3407 W 6TH ST # 100A	90020	10	135B197   969	5502021014	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM			PC Approved	03/16/2011 12:00:00 AM	ADDRESS	34.06373	-118.29596	TENANT IMPROVEMENT IN AN EXISTING COMMERCIAL SPACE-BEAUTY SALONPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38141	15041-10000-26554	1431 S TROTWOOD AVE	90732	15	012B189    32	7560012012	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Expired	10/04/2017 12:00:00 AM	ADDRESS	33.73048	-118.31339	PV1 ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY DWELLING. (1) INVERTER 6KW, (26) MODULES.(26) kyocera #ku2656zpa(1) #PVI-6000-OUTD-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38142	15041-20000-01278	20920 W WARNER CENTER LANE	91367	3	174B109   259	2149017012	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.17451	-118.58895	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO EXISTING OFFICES. SUITE A. 3715 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38143	11041-10001-11987	3620 S MCCLINTOCK AVE BLDG 124	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.0213	-118.28935	Modification to an approved set of plans.  Addition of studio lighting used for filming.  Lighting is exempt from Title 24 calculations.  Plan check was for energy only.  <<<<<<<TI TO AN EXISTING AUDITORIUM ON USC CAMPUS.  PLAN CHECK IS FOR ENERGY ONLY.  Over the counter PLAN CHECK ONLY.  SEELEY G. MUDD BUILDING LECTURE HALL -- BUILDING # 124>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38144	19041-10000-21419	7340 N RESEDA BLVD	91335	3	186B125   757	2119019031	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			PC Info Complete	06/05/2019 12:00:00 AM	ADDRESS	34.2041	-118.53583	PC FOR FA, SYSTEM CONSISTS OF 1 FACP AND 4 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38145	12041-10000-03405	305 N BREED ST	90033	14	129A223   232	5175011027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00, 2044.20	Electrical	Electrical	Public Safety Only			02/14/2012 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	05/23/2012 12:00:00 AM	ADDRESS	34.04755	-118.20883	fire alarm with sprinkler monitoring system in a Walgreens	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38146	14041-20000-18922	13160 N COURBET LANE	91344	12	222B133    37	2602005014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.3086	-118.50641	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(16) SOALR WORLD SW275M MODULES(1) POWER ONE PVI 4.2 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38147	19041-20000-15609	3036 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38148	13041-20000-26816	4311 N FORMAN AVE	91602	4	165B177  1085	2424023011	RE11-1, H	South Valley				1431.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.14847	-118.35286	New Rooftop PV System for an existing single family dwelling.(($0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38149	18041-10001-16008	4653 W BEVERLY BLVD	90004	4	138B193   400	5522032023	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	34.07641	-118.31094	PLAN CHECK ONLY. DELTA 4 CHANGES TO AN APPROVED SET. REMOVING THE FIRE ALARM SYSTEM NOTES FROM THE FRONT PAGE PER INSPECTOR'S REQUEST. Original Scope: ((TI to (E) commercial restaurant space.  Plan check for energy.  Building permit under 18016-10000-08138. ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38150	19041-10000-06567	2316 E IMPERIAL HWY WOMEN'S-STRUCT.	90059	15	084B217    22	6067014901	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	33.92887	-118.23076	EMERGENCY HOMELESS SHELTER FOR THE HOMELESS. SCOPE OF WORK INCLUDES THE FEED TO WOMEN SHLETHER STRUCTURE. B#19010-10000-00751	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38151	17041-10001-34758	1910 E OLYMPIC BLVD	90021	14	121-5A215 121	5166025005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM			PC Approved	05/01/2019 12:00:00 AM	ADDRESS	34.027	-118.2375	DELTA 2 REVISIONS TO PERMITTE DSET- REVISED LIGHTING SYSTEM AND CHANGE HVAC TO SPLIT SYSTEMS((((((((PC for power and energy for new three story warehouse building. PC for new 240/120V 800A service. Installing new switchboard, panels, circuits, equipment, lights, elevator. Total area	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38152	19041-10000-16880	11221 N GLORIA AVE	91344	12	210B141   273	2666024007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.27425	-118.47991	PV1. SYSTEM SIZE OF 9.76 KWdc WITH (32) MODULES P320 OPTIMIZERS, (1) SOLAR EDGE SE10000H INVERTER, (1) 200A PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38153	10041-20000-10288	12780 N CHALON ROAD	90049	11	141B137    49	4493005011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	12/06/2011 12:00:00 AM	ADDRESS	34.08327	-118.49819	Plan check new installation of 14.4 KW photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38154	16041-10000-05839	12101 W SATICOY ST	91605	2	186B165   197	2307013013	(Q)C2-1VL, C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.20862	-118.39722	T-24,  TENANT IMPROVEMENT OF AN EXISTING OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1266.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38155	12041-20000-22288	2844 W ROWENA AVE #A	90039	4	151-5A207 173	5434033010	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.10762	-118.26616	New photovoltaic system for a single family residence.  Unit A.  System uses Enphase microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38156	14041-20000-17645	19301 W VANOWEN ST STE 104	91335	3	183B117   994	2130017003	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Closed	03/19/2015 12:00:00 AM	ADDRESS	34.19397	-118.55381	TI to (E) commercial restaurant space.  Plan check for Title 24 Part 6 for changes to lighting system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38157	17041-30001-46554	100 WORLD WAY Space 140	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM			PC Info Complete	05/03/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	Change to approved set by removed and adding equiptments. All changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38158	12041-10000-23854	500 S VIRGIL AVE # 302	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	CHANGE OF USE FROM OFFICES TO DENTAL OFFICESSUITE 302	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38159	16041-10000-27511	15239 W LA CRUZ DR	90272	11	129B125   795	4412002017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.04564	-118.52549	Plan check for T-24 only. TI to an (E) classrooms at Seven Arrows Elementary, total affected area: 3,804 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38160	18041-10001-16711	1031 N SWARTHMORE AVE #1-106	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM			PC Approved	11/19/2018 12:00:00 AM	ADDRESS	34.0482	-118.52534	ADDED 4 CKTS TO NEW RESTAURANT - PERMIT WAS RECENTLY FINALED PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38161	15041-20000-07766	15910 W VENTURA BLVD SUITE 1010	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.15561	-118.47969	PLANCHECK FOR T24 ENERGY. OFFICE TENANT IMPROVMENT. NEWLY CONNECTED LOAD <400 AMPS. 3242 SQFT. SUITE 1010.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38162	17041-10000-13487	10250 W SANTA MONICA BLVD FC22	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Tenant Improvement at Wexler's Deli Century City Mall #FC22. Service and Dist.board all existing.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38163	18041-10000-24136	14001 W OSBORNE ST	91331	6	195B153   210	2642031021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.23346	-118.43824	PLAN CHECH FOR POWER AND ENERGY FOR - CONVERTED WAREHOUSE/RETAIL BLDG. INTO CHRONIC DIALYSIS CLINIC. - TOTAL NEW CONNECTED LOAD APPROX. 250A TOTAL AFFECTED AREA = 9732 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38164	19041-10000-51926	4126 N ALEMAN DR	91356	3	165B117   471	2178005066	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Issued	12/30/2019 12:00:00 AM	ADDRESS	34.14488	-118.56464	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 11.88KWdc (11.34KWac) USING 36 PANASONIC VBHN330SA17 MODULES AND 36 ENPHASE IQ7X-96-2-US MICROINVERTERS.CONNECTED TO A 200 AMP EXISTING SERVICE. MAIN BREAKER DOWNSIZED TO 175 AMP UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38165	17041-20000-38696	8913 N MEGAN AVE	91304	7	195B101    97	2010021043	(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.23225	-118.60631	pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38166	19041-10000-29794	783 W GATUN ST 217	90731	15	021B197  1087	7445002***	[T][Q]RD1.5-1	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.75748	-118.29434	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 5.00KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 13 MODULES USING P400 OPTIMIZERS AND 2 ESS(TESLA POWERWALL) CONNECTED TO EXISTING 200 SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38167	15041-20000-28383	5111 N WOODLEY AVE	91436	5	171B141   354	2260020012	RA-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Expired	09/22/2017 12:00:00 AM	ADDRESS	34.16245	-118.48385	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38168	13041-10000-03882	4635 W PICO BLVD	90019	10	129B185   877	5083031079	C4-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.04896	-118.33663	T24 for reatil store. Plan check for lighting only. 5131 sqr ft. Permit to be pulled at Plan Check Counter ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38169	19041-20000-23124			6	192B133   299	2204033010	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM			PC Approved	06/17/2019 12:00:00 AM	PIN	34.22040922	-118.50382249	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.this is an additional system to an existing pv system.  this is plan check only.  permit fees paid under apllication numberr 19041-90000-20766	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38170	13041-10001-18034	4335 S GLENCOE AVE	90292	11	105B153    56	4212004015	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	33.98632	-118.43959	SUPPLEMENTAL TO APPROVED SET, CHANGES AND THE DELTA FOR 11(REWIRING). PERMIT TO BE ISSUED UNDER MASTER APPLICATION.TOTAL AREA 24000 SQ FT.ORIGINAL WAS CHECKED BY MEHDI. {{{PC for power only. New meter section 800A 'MS'. and 3 new panels 'AH', 'BH', and 'HP'. everything else existing (AC-1/2 and panels  AL and BL) and loads as well. not a hazardous location per applicant. only sells autoparts. 2 weeks from 7/9/2013. customer agrees to proide an official fault current report - either on computer or henry abrari within 2 weeks. should this information not be provided, then approval will be revoked.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38171	18041-10000-01672	9080 W PICO BLVD	90035	5	132B169   884	4305001020	C4-1VL-O, R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.05508	-118.38965	INTERIOR LUMINAIRES COMPONENT MODIFICATIONS IN PLACE- CHANGING OUT TO LED LAMPS AND LED DRIVERS. ALSO, 1 EXTERIOR LUMINAIRE.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38172	10041-20001-25105	7901 N LINDLEY AVE	91335	3	189B125   489	2102014018	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Info Complete	08/22/2013 12:00:00 AM	ADDRESS	34.21431	-118.5275	((supplemental application for changes to approved set of plans. reduce size of AC units and relocation of AC units. addition of fan coil units. changes clouded)))Relocating 400 Amp distribution board, installing 2 new panels, branch circuits, air condition units, and lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38173	16041-10000-25438	725 S FIGUEROA ST ste. 1080	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for T-24 only. TI to an (E) office building. Install new lights and receptacles. Total affected area: 2,503 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38174	08041-10003-23810	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM			PC Approved	10/15/2012 12:00:00 AM	ADDRESS	33.97451	-118.42531	Delta 9 changes to permitted set of plans.Changes are clouded and marked Delta 9  on the plans- Some HVAC UNITS ARE 480V NOT 208V AND FEW OUTLETS ADDED IN THE COURTYARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38175	14041-20000-29534	17141 W TRIBUNE ST	91344	12	207B133    85	2696023028	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.26736	-118.50684	PV1INSTALL ROOF MOUNTED PV STSREM SIZED 4.0KW INTERCONNECTED WITH MSP.(16) SOLARWORLD SW 275 MODULES(16) ENPHASE M250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38176	16041-10000-20451	1271 E 49TH ST	90011	9	111A211   161	5107020029	RD2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	07/16/2016 12:00:00 AM	ADDRESS	33.99904	-118.25254	PV1, rooftop solar installation, 3.0 kW Ac system,    (11) Solar city standrad module    (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38177	16041-20000-28495	10250 W CONSTELLATION BLVD FLR 18-20	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING (HIGH RISE).  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL QUARE FOOTAGE 5395.  WORK TO BE PERFORMED IN FLOORS 18-20.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38178	16041-20001-21959	9725 N TUNNEY AVE	91324	12	201B117   333	2761034004	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM			PC Approved	07/12/2016 12:00:00 AM	ADDRESS	34.24722	-118.55755	EXPEDITEPV1(ACM) INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.8KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38179	14041-10000-33809	1007 E 51ST ST	90011	9	111A209   366	5108015028	RD1.5-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	33.99676	-118.25797	PV1.  Install 4.59 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38180	11041-10000-27505	333 S HOPE ST 20th fl	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check is for change from open area to private offices Title 24 Energy and 1 Emergency ckt. 20th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38181	15041-20000-27287	16032 W VALLEY VISTA BLVD	91436	5	168B141   860	2283015007	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.15302	-118.4827	Plan check for a PV1 roof-mounted PV system. System size is 23.1 kWac and consists of (3) inverters, (73) modules, and (1) load center.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38182	14041-10000-10386	11220 N TELFAIR AVE	91331	7	210B153   314	2616021062	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.27382	-118.43617	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38183	11041-20000-25421	19231 W VICTORY BLVD	91335	3	180B117   799	2128031153	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			PC Info Complete	12/02/2011 12:00:00 AM	ADDRESS	34.18678	-118.55214	Adding an new outlet for an MRI trailer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38184	17041-20000-04644	14216 W GILMORE ST unit 4	91401	6	180B153   960	2237020009	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.18753	-118.4429	pv2install roof mounted pv system sized 3kw interconnected with msp.  This is system 4 of 5.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38185	14041-10001-06733	3753 S GRAYBURN AVE	90018	10	117B185   390	5033009001	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.01844	-118.33205	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38186	14041-20000-18488	12963 N LOUISE AVE	91344	12	222B129   264	2601055035	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.30227	-118.52482	PV1 Standard plan: 7.8kw roof-mounted system with 26 canadian solar modules and optimizer SE p400, and (2) Solaredge-3800 inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38187	18041-20000-00754	700-800 WORLD WAY 1140	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	Plan check for Title 24 only. Project site is an existing commercial space with Terminal 7. Project scope is a tenant improvement. Total lighting area = 329 sq. ft.Note: Building application has been generated under 17016-10000-35738	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38188	19041-20000-15826	3540 S FIGUEROA ST	90007	9	118-5A201   7	5123022031	USC-1B	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.01945	-118.28133	PLAN CHECK FOR T24 ONLY. REPLACEMENT OF TWO EXISTING OUTDOOR SIGN AND INSTALLING TWO NEW OUTDOOR SIGN LIGHTING FOR EXISTING COMMERCIAL HOTEL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38189	16041-20000-05135	818 N AVENUE 51	90042	1	153A225    14	5478015005	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.1155	-118.20625	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (21) modules, (21) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38190	12041-20000-27450	20106 W PIENZA LANE	91326	12	213B113   321	2701063***	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	03/05/2013 12:00:00 AM	ADDRESS	34.27999	-118.57492	6.86kw  rooftop, photovoltaic systems, for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38191	14041-20000-03135	202 N GRAMERCY PL	90004	4	138B193   763	5516020011	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.07484	-118.31233	PV1  SYSTEM WITH MICROINVERTERS AND CENTRAL INVERTER. 1.1KWAC OF MICROINVERTER WITH 3.5KWAC CENTRAL INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38192	10041-20000-16817	15750 W STRATHERN ST	91406	6	189B141    84	2206003016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.21559	-118.47652	PLAN CHECK T-24 ENERGY FOR TENANT IMPROVEMENT EQUIPMENT ROOM INSIDE (E) WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38193	19041-10000-52854	520 S MATEO ST Offices	90013	14	126A217   216	5164003015	M3-1-RIO  /  [T][Q]C2-2-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	11/28/2022 12:00:00 AM		Issued	11/28/2022 12:00:00 AM	ADDRESS	34.04103	-118.2329	(TWO NEW TOWERS) THIS PROJECT: NEW 6 STORY OFFICE BULDING. CORE AND SHELL ONLY. THE POWER TO THIS BUILDNG IS FROM THE RESIDENTIAL BULIDING.BULDING PERMIT: 18010-10000-05907((((PROPOSED 35 STORY MIXED USE HIGHRISE BUILDING. 475 LIVE/WORK UNITS, OFFICE, RETAIL AND 2 LEVELS OF BASEMENT GARAGE.  11% (53 UNITS)  OF THE TOTAL UNITS (475)  WILL BE RESERVED  AS VERY LOW INCOME UNITS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38194	16041-20000-32393	5319 N CRANER AVE	91601	2	171B173   234	2416003018	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.16756	-118.36932	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from manufacturing to recording studio. Total lighting area = 640 sq. ft. Note: Building application has been created under 15016-20000-25389	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38195	15041-10003-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED AS DELTA 10,11, AND 12 ON PLANS. CHANGES TO DEMO SET AND MINOR PANEL SCHEDULE REVISIONS. NO LIGHTING CHANGES. CHECKING FOR UPDATED PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38196	16041-10000-35218	606 N ARDMORE AVE	90004	13	141B193   871	5520002021	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Apartment			10/05/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Issued	11/18/2016 12:00:00 AM	ADDRESS	34.08187	-118.30153	Plan check for PV roof mounted system on multiple untis building. Service size: 400A splite bus(Exising).  System size: 3.0kW with 12 modules and 1 inverter(3.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38197	17041-20001-21855	5555 W MELROSE AVE Bldg #166	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	[[[10/12/17 CHANGES TO APPROVED T24. DELTA 1 CHANGES ONLY. PLANCHECK ONLY. ADDITION OF OFFICE AND LIGHTING]]]Plan check for energy only. TI to basement offices in building #166 (Paramount Studios). New lighting (incl. emergency) - 2366sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38198	14041-10000-13006	1825 N CAHUENGA BLVD	90028	13	150A187   273	5546001014	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Apartment			05/15/2014 12:00:00 AM			PC Approved	05/15/2014 12:00:00 AM	ADDRESS	34.10467	-118.33027	permit to be pulled at EPC counter only. Plan check only for energy. TI (E) LAUNDRY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38199	16041-30000-03140	8985 W VENICE BLVD #B-1	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.02733	-118.39241	Plan check for power and Title-24.  Total area = 33,745 sq. ft.     T.I. for retail grovery store (converting existing grocery store to Sprouts Farmers Market).  Distribution boards to remain existing with new subpannels and associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38200	18041-10000-19600	3435 W WILSHIRE BLVD #1550	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.06194	-118.29866	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT TO (E) OFFICE SPACE ON 15TH FLOOR. TOTAL AREA 3,874 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38201	15041-20001-31009	841 N KENTER AVE	90049	11	138B137   328	4426030007	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM			PC Approved	10/08/2015 12:00:00 AM	ADDRESS	34.07374	-118.49131	Expedite per applicant request[[[[[[[[[Plan check for PV roof mounted system. System size: 15.4kW with 60 modules and 2 inverters (7.7kW)]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38202	16041-10001-25271	17352 W SUNSET BLVD BUILDING-CD	90272	11	126B117   516	4415018016	C2-1VL, [Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Apartment			04/13/2017 12:00:00 AM			PC Approved	04/13/2017 12:00:00 AM	ADDRESS	34.03939	-118.55367	Changes to approved set of plan, changes to secondary connection from without fuse to with fuse version, and the changing the feeder size related. Plan check only.changes clouded as delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38203	14041-20000-33190	19524 W NORDHOFF ST #2	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.23527	-118.55871	PC FOR T24 ENERGY ONLY. PERMIT TO BE PULLED UNDER THIS APPLICATION. OK FOR EXPRESS. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38204	11041-20000-15636	11122 W MAGNOLIA BLVD	91601	4	171B173   623	2353005010	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	34.16471	-118.37329	NEW 600 AMP SERVICE. FOR A CORE & SHELL. EPC IS FOR POWER.   *****Engineer lost the approved set of plans.  A new set of plans have been stamped so an additional fee of 2 additional hours has been added to the FINAL pay period. *****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38205	14041-20001-01434	672 E INDIANA AVE	90291	11	111B145  1312	4239008019	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	33.99723	-118.46715	(((EXPEDITE FEES)))PV1 TWO FAMILY DWELLING. PV SYSTEM SPLIT WITH ANOTHER ADDRESS. THIS PLAN CHECK COVERS THIS ADDRESS RANGE. TRANSFORMERLESS INVERTER WITH POWER OPTMIZERS. TOTAL SYSTEM SIZE 3KW AC USING9 MODULES. SYSTEM INTERCONNECTION IS 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38206	15041-20001-11209	10807 W BELLAGIO ROAD	90077	5	138B149    26	4362006006	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.07832	-118.45299	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 18 kWac.  Two inverter system with 5 strings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38207	15041-20000-24964	18159 W MEDLEY DR	91316	5	165B125   273	2184040021	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.14726	-118.5285	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel. (37) Kyocera KU 2656 Modules(1) ABB Fronius Primo 7.6 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38208	17041-10000-07547	510 N BROAD AVE	90744	15	030B209   811	7418007021	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	33.77606	-118.26064	PC FOR ENERGY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL ARAE 32575 SQ FT. /OUTDOOR/	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38209	16041-10000-36176	3644 N TERRACE VIEW DR	91436	5	162B133   279	2287007035	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.13736	-118.49976	PV1 SFD TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. SYSTEM USES 32 MODULES TOTAL.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38210	15041-10001-24535	18761 W CLEARBROOK ST PV1	91326	12	213B121   722	2871016035	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.27745	-118.54275	02/08/16PV1, ROOF MOUNTED SYSTEM USING CENTRAL INVERTER. (27) MODULES AND (1) 6KW, INVERTER. INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT #15041-10000-24535. (((INSTALL PV SYSTEM (27 PANELS, 1 INVERTER 7.02 KW) Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38211	18041-10000-19330	1133 S HOPE ST	90015	14	127-5A207 285	5138014006	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Closed	08/11/2020 12:00:00 AM	ADDRESS	34.0416	-118.26394	PC FOR TEMP POWER FOR  New 28 story residential towerSCOPE INCLUDES NEW SERVICE 1600A  277/480V WITH SKIDS, ELEVATORS AND CRANES. ..... 24 levels of residential, 1 level of amenity space, and 5 level of parking above grade and 3 level below grade with ground level commerical space (core and shell).B# 13010-10000-02854	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38212	15041-10000-08522	2112 S ZENO PL	90291	11	108B145  1689	4237003006	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	33.98937	-118.45933	Energy plan check for an office T.I, total area is 2452-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38213	10041-20000-13268	11641 W PENDLETON ST	91352	6	195B169   368	2631017043	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Finaled	05/02/2011 12:00:00 AM	ADDRESS	34.229	-118.38639	PLAN CHECK FOR INSTALLATION OF 48.79KW PHOTOVOLTAIC SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38214	12041-20000-17789	14925 W MAGNOLIA BLVD	91403	2	172-5A149 270	2250021001	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00	Electrical	Electrical	Apartment			07/31/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.16501	-118.45824	New fire alarm for 49 units apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38215	08041-10001-14745	2235 S MINER ST	90731	15	018B201   130	7440026903	M2-1, [Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM			PC Approved	03/24/2011 12:00:00 AM	ADDRESS	33.72532	-118.27756	REVISIONS TO PERMITTED SET OF PLANS-REWIRING OF UTILITY PEDESTALS  AT THE LONG DOCK AND AT THE LIFEGUARD DOCK>>>>>>>>Cabrillo Way Marina power service and distribution plus outdoor lighting(4.4 million sq. ft on OLTG-2-C, 24 hours charged for T-24 fees)  See application comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38216	18041-20000-27686	8479 W MELROSE PL	90069	5	141B173   428	5528001058	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.08373	-118.376	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38217	15041-10000-37290	1851 N GAFFEY ST	90731	15	024B197    78	7442022021	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM			PC Approved	11/05/2015 12:00:00 AM	ADDRESS	33.7617	-118.29322	PC FOR ENERGY FOR A T.I,  THE GAS COMPANY SEMPRA ENERGY. TOTAL AREA 1250 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38218	19041-10000-34712	17407 W CANTARA ST	91325	12	192B129   496	2201012026	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.21954	-118.51238	pc for pv-1, system size 4.650 KW. 15 panels and 1 central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38219	09041-10001-24382	10329 W PALMS BLVD	90034	5	120B161   400	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2699.07	Electrical	Electrical	Apartment			03/29/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.02679	-118.40832	Modification to approved set of plans for T-24 ONLY, no other changes other than T-24 are a part of this plan check.       <<<<<New Mixed Use project - core for retail / apartment (3-7 typical; 31 units) / parking - Permit is for new service (120/208), new distribution, new panels, new equipment, new ckting for residential / commercial use.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38220	18041-10000-22089	1005 W 64TH ST	90044	8	105B197  1260	6003031904	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	33.98153	-118.29218	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP, 54 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38221	10041-20004-14353	1680 N VINE ST	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM	11/03/2011 12:00:00 AM		Permit Expired	11/26/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	Delta 5 revision plan check. Changes consist of adding three 75KVA transformers for elevators and replace four panels to new 10K AIC rated panels. No change to load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38222	18041-10000-17997	100 WORLD WAY T1-STE 132	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES INSTALLING THREE LED SIGNS FOR LAX TERMINAL 1 SUITE#132.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38223	11041-10001-04540	1888 S CENTURY PARK EAST #550	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM			PC Approved	03/11/2011 12:00:00 AM	ADDRESS	34.06104	-118.41402	Tenant Improvement for Spec Suite, relocate lights, switches, outlets, all on existing circuits in Suite # 550. Plan Check is for T-24 Energy Calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38224	10041-10000-02019	117 E WINSTON ST	90013	9	129A213   226	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			02/11/2010 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	05/21/2012 12:00:00 AM	ADDRESS	34.04713	-118.24718	Adaptive Reuse to live work complex.  43-units; Permit is for new service, new distribution, new panels, new equipment, new ckts, and lighting.  A variance to separate the electrical and fire alarm plan check was submitted on June 24, 2010.  p/c is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38225	11041-10000-08839	3249 W CASITAS AVE	90039	13	153B209   561	5436002026	MR1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			PC Info Complete	05/02/2011 12:00:00 AM	ADDRESS	34.11588	-118.25149	T.1.  EXISTING RESTAURANT.  TITLE 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38226	17041-10000-20480	835 W JEFFERSON BLVD Unit 1735	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	PLAN CHECK F0R POWER AND ENERGY FOR FIRST FLOOR TENANT IMPROVEMENT FOR NEW TACO RESTAURANT (24'X50' SPACE). TOTAL AFFECTED AREA = 1090 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38227	15041-20002-37382	7900 N BALBOA BLVD BLD. LIMA	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM			PC Approved	11/13/2015 12:00:00 AM	ADDRESS	34.21347	-118.50092	11/13/15CHANGES TO AN APPROVE SET. CHANGES MADE UNDER DELTA 2. PANEL L5 IS FOR FUTURE USE. ((((**11/10/15: Plan check only, applicant request per inspector**Permit fees paid under PCIS#15041-20000-37382200AMP (N) SERVICE. INSTALL (N) SUB-PANELS AND CIRCUITS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38228	14041-20000-08625	6350 W SANTA MONICA BLVD 131-134	90038	13	144B185   733	5533016002	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.0906	-118.32785	PLANCHECK FOR TITLE 24 ENERGY. TENANT IMPROVEMENT FOR NEW PARTITION AT SUITE 131-134 OF EXISTING OFFICE(PRODUCTION OFFICE). 1888 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38229	16041-10005-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			Corrections Issued 2	07/17/2018 12:00:00 AM	PIN	34.2363795	-118.55851216	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES ARE CLOUDED UNDER DELTA 8 B8 ONLY - SCOPE INCLUDES ADDITION OF ROLLER SHADES    PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE 214 UNITAPARTMENT WITH RETAIL CORE & SHELL. 4 FLOORS OF RESIDENTIAL OVER 2 FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL.  THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMPS, 4000 AMPS, AND 1000 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38230	17041-10000-21151	3321 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			08/15/2017 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.0275	-118.3723	Plan check for Power and Title 24.  New mixed-use residential tower.  30-story residential tower with 300 units and structured parking located within a 5-story podium and a single level basement.  Retail spacewill be provided on the ground floor, along with tenant amenity areas on the 6th and 30th floors.  New 1000 amp 4,160 volt Main Switchboard with two 250 HP fire pumps and 1,000 kW diesel generator backup.  The incoming utility service is provided under separate plan check number 17041-10000-23479. Lighting area = 243,170 sq. ft. (indoor) + 45,288 sq.ft. (outdoor)       Building permit #16010-10000-04211	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38231	13041-10000-04067	7520 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Issued	02/15/2013 12:00:00 AM	ADDRESS	34.20692	-118.4942	INSTALLATION OF A NEW MONIOTORING FIRE ALARM SYSTEM AND NEW PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38232	17041-20001-35357	11647 N BALBOA BLVD	91344	12	213B133   276	2607013008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2017 12:00:00 AM			PC Approved	10/07/2017 12:00:00 AM	ADDRESS	34.28239	-118.50232	expeditepv1install roof mounted pv system sized 17.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38233	12041-20000-27612	453 E 119TH ST	90061	15	084B205   969	6083022028	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			11/15/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Expired	12/10/2014 12:00:00 AM	ADDRESS	33.92476	-118.26571	Replacement of FACP with like, all devices are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38234	19041-10000-53380	17401 W VENTURA BLVD	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	06/15/2021 12:00:00 AM		Permit Finaled	09/30/2021 12:00:00 AM	ADDRESS	34.16136	-118.51189	FULL PC FOR A  TI. SCOPE OF WORK INCLUDES NEW POWER EQUIPMENT SUCH AS PANEL BOARDS, 2 TRANSFORMERS, AND CIRCUITS. TOTAL AFFECTED AREA FOR T24 IS 3537 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38235	11041-20000-15828	6550 N ODESSA AVE	91406	6	180B137   319	2233033907	[Q]A1-1XL	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	08/09/2011 12:00:00 AM		Permit Finaled	02/10/2012 12:00:00 AM	ADDRESS	34.1901	-118.49001	TI IN THE RESTROOM & SALE AREA OF THE GOLF COURSE. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38236	16041-10000-45602	4914 N ALHAMA DR	91364	3	168B105   272	2167012028	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/04/2017 12:00:00 AM	ADDRESS	34.15877	-118.59312	PV, INSTALLATION OF 4.24 KW DC SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(16) MODULES: HANWA/QCELL. Q-PLUS-G4 265 W(1) INVERTER: SOLAREDGE SE3800A-US 240V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38237	16041-10000-34525	1149 S BROADWAY 3RD FLR	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.03859	-118.26015	PC for title 24. Tenant improvement to public works building on 3rd floor. Scopwe includes new lighting and power. Total sqft = 1535. B#16016-10000-21182	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38238	13041-10000-08390	627 S ROSSMORE AVE	90005	4	135B185   534	5505013007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.06277	-118.3278	POWER PLAN CHECK FOR ROSSMORE RESIDENCE. UPGRADE TO 800A SERVICE. CONNECTED LOAD EXCEEDS 400A. HOUSE 7660 SQRFT. ADDITIONAL GARAGE 1450 SQRFT. METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38239	18041-10000-19384	22027 W VALERIO ST	91303	3	186B101   606	2023004018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.20479	-118.60695	INSTALL A NEW 3.54KW / 12 MODULES PV SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38240	17041-10000-42597	8510 W FOOTHILL BLVD	91040	7	204B189    36	2560005022	C2-1VL, RD5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.25954	-118.31804	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38241	15041-20000-06068	7247 N HAYVENHURST AVE Unit A5	91406	6	186B137   305	2226001906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.20296	-118.49362	Plan check for power and Title 24 (energy).  Total area = 8,868 sq. ft.T.I. to existing commercial warehouse and office space.  New lights and panel upgrade for 3 200 A panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38242	12041-10000-15537	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	Relocate and install new motors at an existing refinery in a classified area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38243	16041-20001-20060	2180 W CAMBRIDGE ST	90006	10	126B193   178	5074012003	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.04438	-118.30556	EXPEDITEPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38244	19041-20000-39299	11357 W HENDLEY DR	91604	2	162B173   803	2378018031	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	PIN	34.13841903	-118.37686718	PV1.  Install 7.59 kW DC / 6.451 kW AC roof mounted grid tied PV system.  (23) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38245	16041-20000-22382	6325 W HOLLYWOOD BLVD	90028	13	148-5A187 151	5546004012	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.10178	-118.32765	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 1500 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38246	16041-10000-14481	2626 E 25TH ST	90058	14	117A219   417	5168022006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.0152	-118.22477	REMODEL PORTION OF EXISTING MANUFACTURING BUILDING, ADDING NEW MOTOR LOAD WITH TOTAL NEW CONNECTED IS LESS THAN 400A.  PC FOR T-24 ONLY. TOTAL AREA: 8,112 SQ.FTB# 16016-10000-04343	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38247	13041-20000-01788	23401 W MAESTRO PL PV-1	91304	3	189B093   816	2027001030	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.21002	-118.63886	Plan check for PV sfd. 13.2kW. DC negatively grounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38248	17041-10000-02444	3121 W OLYMPIC BLVD #102	90006	10	129B193   271	5080024027	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM			PC Info Complete	01/26/2017 12:00:00 AM	ADDRESS	34.05277	-118.30387	Plan check for Title 24 only in existing 2 story building T.I. Total area: 2470 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38249	17041-10000-36399	328 E 1ST ST 3RD FLOOR	90012	14	129A215    10	5161017031	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.04967	-118.24011	INTERIOR TI: NEW FITNESS ROOM & LAUNDRY ACCESSORY TO HOTEL GUESTROOMSNEW PANEL, CIRCUITS, AND LUMINAIRESPLAN CHECK IA FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38250	14041-20000-26708	12663 W SANDHILL LANE Unit #1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97743	-118.41479	PV2Install roof-mounted solar array on Unit #1 of commercial building. Each of the 3 Units will have their own solar array, interconnecting in their respective unit panels. All Unit panels fed off of the same 400A distribution board.System size: 3kW.(1) PVI 3.0-OUTD-S-US-A transformerless inverter(6) SunPower SPR-230NE-BLK-D pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38251	17041-20000-35776	17344 W SIGNATURE DR	91344	12	216B129   290	2606014046	RA-1-H, RE15-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.28703	-118.51236	Plan check for a PV1 roof-mounted PV system. System size is 13 kWac and consists of (2) inverters, (52) modules, and (1) load center.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38252	14041-20000-01329	3719 N BEVERLY RIDGE DR	91423	4	162B149   466	2274016009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.13825	-118.44748	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38253	13041-20000-14192	19510 W MOBILE ST	91335	3	180B117   746	2132013009	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.18806	-118.55857	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.9 KW. 12 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38254	13041-10001-32951	11714 W REMINGTON ST	91342	7	213B169   451	2531023026	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	05/09/2014 12:00:00 AM	ADDRESS	34.28146	-118.38798	Expedited RSES plan check per applicant request.[][]PV1, Install  7.75 kw DC roof-mounted solar array, interconnect with service panel.(2)Transformerless inverters: SOLAREDGE SE3800-US. (31) modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38255	12041-20000-16424	14237 W VAN NUYS BLVD	91331	6	201B153   110	2647022016	[T]RD2-1	North Valley	Arleta - Pacoima	Arleta		1192.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.25072	-118.44367	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38256	14041-10000-13821	6835 N BELLAIRE AVE	91605	2	183B161   828	2324015018	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.19493	-118.40958	PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38257	16041-10000-00506	1822 N MARCHEETA PL	90069	4	150B169  1212	5561008030	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM			PC Info Complete	03/24/2016 12:00:00 AM	ADDRESS	34.10534	-118.38897	NEW SINGLE FAMILY RESIDENTIAL, WITH BASEMENT AND FIRST FLOOR LV. 600AMP SERVICE AND 4 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38258	19041-10000-17292	333 S GRAND AVE 710 & 720	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	Energy plan check for an office TENANT IMPROVEMENT. Scope includes new equipment and RELOCATING LIGHTING on the 7th floor with a total area of 874-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38259	16041-20000-29894	18226 W VENTURA BLVD STE 210	91356	3	171B125   309	2181010028	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.16616	-118.52995	TI TO N EXISTING COMMERCIAL BUILDING ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG.  TOTAL SQUARE FOOTAGE 1224 IN SUITE 210.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38260	15041-10000-18984	13910 W FOOTHILL BLVD	91342	7	225B153   354	2509003022	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Issued	08/25/2015 12:00:00 AM	ADDRESS	34.31187	-118.43649	Full plan check for a medical (dental )office T.I with 400-Amp service upgrade and (5) new individual unit panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38261	19041-20000-23051	4241 N FORMAN AVE	91602	4	165B181   442	2424023027	RE11-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.14717	-118.35285	addition of (2) tesla ESS rated at 5KW each to  an exisitng pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38262	13041-20000-29480	2157 N STANLEY HILLS DR	90046	4	151-5A173 112	5567002028	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.11022	-118.37702	"PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12 KW AC USING TWO CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING TOTAL OF 40 MODULES. "" low permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38263	18041-10000-07355	3700 S LA BREA AVE Unit C	90016	10	117B177  1129	5046038025	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.01929	-118.35537	Plan check for Title 24 only in existing sapce. T.I. retail store lighting and receptacles. Total area: 2,192 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38264	14041-20001-09007	7523 N NEWCASTLE AVE	91335	3	186B125   362	2120021028	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.20726	-118.52527	Expedited plan check per applicant request.  (((PV1.  Install 5 kW roof-moutned PV system, interconnect with main service panel.  Transformerless inverter w/ power optimizers: SolarEdge SE5000A-US-ZB-U.  20 modules: Canadian Solar CS6P-250PX.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38265	14041-20000-09780	8914 N WHITE OAK AVE	91325	12	195B129   186	2768027006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.23294	-118.51983	pv1 single family. total system size 7.6 kw ac using 2 central transformerless inverters. nonstandard plan. total of 35 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38266	19041-10000-21362	3602 S LA BREA AVE	90016	10	120B177  1132	5046038023	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.02129	-118.3554	T.I PC FOR TITLE-24 FOR EXISTING RESAURANT. TOTAL EFFECTED AREA 2037 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38267	16041-10000-28929	8500 W BEVERLY BLVD LVL 4	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Issued	08/15/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGE OF USE FROM STORAGE TO NEW OFFICE ON LEVEL 4 PORTION OF GARAGE FOR MALL REBRANDING PROJECTS UNDER PERMITS 14016-10001-15799 AND 15016-10000-28423 AND 16016-10000-01909 CONSTRUCT (N) NON BEARING WALLS, NEW CEILING, MILLWORK AND FINISHES (N) COMPLIANT ADA UNISEX RESTROOM AND REDUCE TWO PARKING FOR (N) ADA PARKING STALLS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38268	18041-10000-40405	5855 N LANKERSHIM BLVD	91601	2	174B169    12	2338016011	[T][Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.17719	-118.3823	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38269	17041-10000-11452	450 S WESTERN AVE #314	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.06562	-118.30887	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT(RESTARANT)PLAN CHECK INCLUDES CONNECTING TO AN EXISTING DISTRIBUTION BOARD, NEW PANELS, AND TOTAL SQ. FT. 1307	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38270	18041-20000-08457	12105 W WATERFRONT DR 2nd Floor	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	33.98095	-118.40764	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,165 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38271	19041-20000-15923	3460 W LARGA AVE	90039	13	153B209   337	5436025011	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.11693	-118.25933	Plan check for PV roof mounted system, system size: 8.64kW DC, 7.6KW AC with 24 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38272	18041-20000-19646	2919 N NORTH BROADWAY	90031	1	138A223    38	5204023003	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			05/25/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.07387	-118.21084	Plan check for power only in existing appartment building. 600A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38273	15041-10002-05124	12655 W JEFFERSON BLVD	90066	11	102B161    13	4211005019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	03/18/2016 12:00:00 AM	ADDRESS	33.97916	-118.41469	03/18/2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA R. CHANGES INCLUDES  PANELS FOR FUTURE TENANTS TO REFLECT THE FIELD.  (((Plan check for power and energy. Renovation of existing office building. Applicant approved to bring in T24 sheets and more panel schedules another day. Verify fees.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38274	18041-10000-17404	11401 W PICO BLVD	90064	11	123B153   298	4260024007	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.03418	-118.44139	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38275	18041-30001-41737	10866 W WILSHIRE BLVD #600	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.05907	-118.442	PC FOR ENERGY ONLY,  SUITE T.I. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3924.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38276	14041-10000-12555	2049 S CENTURY PARK EAST STE # 2600	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.05903	-118.41293	T24 ONLY. TOTAL  AREA 13848 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38277	14041-10000-18581	609 S LINCOLN BLVD	90291	11	111B145   817	4240016053	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	33.99989	-118.46525	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR JUICE SERVED HERE. 1255 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38278	18041-10000-47798	333 S GRAND AVE 1600	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	Energy plan check for an office T.I located on the 16th floor of a high rise building. Scope includes new lighting and equipment with a total area of  1,005 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38279	15041-20000-22175	6933 W HOLLYWOOD BLVD #7635	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.10171	-118.34135	Plan check for Title 24 only existing retail space. Total indoor lighting area: 1,654sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38280	19041-10000-44659	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	03/17/2020 12:00:00 AM		Permit Finaled	02/05/2021 12:00:00 AM	ADDRESS	34.09822	-118.31812	FULL PLAN CHECK FOR A TI LOCATED IN MULTIPLE AREAS OF THE BUILDING. SCOPE IS INCLUDING NEW LIGHTING EQUIPMENT AND TOTAL SQUARE FOOTAGE 12,202. PER BUILDING APPLICATION PHASE 4 - INTERIOR FITOUT TO (E) MIX USE, NEW STAIR, MINOR, INTERIOR DEMO, NEW LOAD AND NON LOAD BEARING PARTITIONS, LEVEL B2, B1, 01, 01M ,2  TO INCLUDE THEATER, OFFICE, AND COMM KITCHEN  REF 16010-10000-04681	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38281	11041-10000-02887	2000 S AVENUE OF THE STAR 1060	90067	1, 5	148-5A215  53	5455001032	C2-2-O, RD2-1-CDO	East Los Angeles, West Los Angeles	Northeast Los Angeles, West Los Angeles	Greater Cypress Park, Westside	YES	1852.03, 2679.01	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM			PC Approved	02/14/2011 12:00:00 AM	PIN	34.10217855	-118.23545495	T-24 only office T.I. with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38282	09041-10003-00584	3201-3245 S FIGUEROA ST	90007	8	120A203   502	5123009012	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	02/23/2010 12:00:00 AM		Permit Finaled	05/27/2010 12:00:00 AM	PIN	34.02243394	-118.28011301	NEW FIRE WARNING SYSTEM FOR 8-STORIES STUDENT HOUSING BLDGING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38283	18041-20001-03021	100 W WORLD WAY Space 166	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Info Complete	10/11/2018 12:00:00 AM	PIN	33.94684048	-118.40128468	Changes to an approved set of plan. Changes include addtion of lighting fixture and update as built drawing. All changes has been clouded as delta 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38284	11041-10000-15461	14006 W RIVERSIDE DR PV3	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	09/27/2011 12:00:00 AM		Permit Closed	10/21/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	INSTALLATION OF 279.36 KW PV SYSTEM ON TOP OF A PARKING STRUCTURE AT THE WESTFIELD FASHION SQUARE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38285	15041-10000-36368	10403 N GLENOAKS BLVD	91331	7	204B165    43	2537002015	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.2587	-118.39636	T-24. Remove HID light fixtures and replace w/ new LED fixtures. SQ ft = 2576	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38286	14041-10000-01731	508 W 155TH ST	90248	15	072B201   186	6120026011	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Expired	09/20/2016 12:00:00 AM	ADDRESS	33.89043	-118.28345	PV1, Install 1.47 KW DC roof-mounted mico inverter solar array on a house, interconnect with main service panel. (6) Modules: Canadian Solar CS6P-245P with (6) Inverters: Enphase M215.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38287	17041-20001-43680	7957 N SANGAMON AVE	91352	2	189B181   194	2403013006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.21599	-118.34739	EXPEDITED PER APPLICANTS REQUEST.ENERGY STORAGE SYSTEM + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.85KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38288	10041-10000-04830	500 W WORLD WAY Terminal 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM	06/01/2010 12:00:00 AM		Permit Finaled	04/08/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check T-24 Energy (general/emergency) lighting for LAX Terminal 5 Renovations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38289	15041-10000-14656	600 WORLD WAY TR 6-SPACE 632	90045	11	141B185    87	5533026015	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Expired	10/16/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR EXPRESS SPA. TOTAL AREA 500 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38290	19041-20000-39581	20730 W PRAIRIE ST	91311	12	198B109    81	2748002048	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	09/01/2020 12:00:00 AM		Permit Finaled	10/22/2021 12:00:00 AM	ADDRESS	34.24073	-118.58534	New distribution, power, and lighting for warehouse/office TI.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38291	14041-20000-17132	10526 W DUBNOFF WAY BLDG G	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM			Corrections Issued	07/21/2014 12:00:00 AM	ADDRESS	34.18656	-118.36106	"T.I. for class in building G.  Install branch circuits and lighting.  Plan check for power and energy.Note 1:   Applicant will submit the approved within 3 days.  See ""Applicant Comment"" for more info."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38292	15041-10000-24912	3428 W 8TH ST	90005	10	132B193   625	5093017012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM			PC Approved	08/03/2015 12:00:00 AM	ADDRESS	34.05754	-118.30431	PC AT COUNTER T-24 ENERGY ONLY. SCOPE OF WORK INCLUDES CHANGE OF LIGHT FIXTURES TO LED LIGHT ON EXISTING KARAOKE RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38293	11041-20000-16136	12930 W VENTURA BLVD #104	91604	5	165B161  1036	2385026024	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	08/26/2011 12:00:00 AM	ADDRESS	34.14513	-118.41481	Plan check T24 Energy for interior tenant improvements in beauty salon. Permit for new lighting, switches, and receptacles on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38294	12041-10002-19875	5450 S LINCOLN BLVD	90094	11	102B157   293	4211022004	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	ADDRESS	33.97348	-118.43093	Plan check for revision new methane detection system for Playa Vista Medical Center. Permit on #12041-20000-19875.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38295	17041-20002-29102	15253 W GOLDEN CT	91342	7	219B145   688	2611041026	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.29481	-118.46533	[[11/21/17 CHANGES TO APPROVED SET. RELOCATING THE ENERGY STORAGE SYSTEM ]]]Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6 kWac and consists of (1) inverter, (19) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38296	15041-20000-41570	8813 N MURIETTA AVE	91402	6	195B153   648	2639023020	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Expired	01/12/2018 12:00:00 AM	ADDRESS	34.23061	-118.44213	PV1 roof mounted solar installation 3.8 kW AC interconnect with (Upgrade) 200A MS.(10) SPR327NE-WHT-D(1) SMA SB3800TL-US-22Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38297	14041-20000-23156	19625 W ROSCOE BLVD	91324	12	192B117   721	2783012025	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.22054	-118.56091	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1 SFD. TOTAL SYSTEM SIZE 10.8KW AC USING 3 TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. TOTAL OF 55 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38298	17041-20000-42400	4357 E SAN RAFAEL AVE	90065	1	153A223   350	5471009008	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.11212	-118.21293	PV1.  Install 11.05 kW roof mounted grid tied PV system.  (34) modules with (2) 5.2 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38299	10041-10000-14336	1132 S SANTEE ST	90015	9	124-5A209  51	5145022005	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	34.0369	-118.25668	TI IN AN EXISTING RETAIL STORE. PLAN CHECK IS FOR Title 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38300	10041-10000-20222	810 N CROFT AVE	90069	5	141B173   153	5529003019	[Q]R3-1	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Apartment			10/12/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.08572	-118.37409	Fire alarm system for 6 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38301	15041-20000-21894	12813 W FRIAR ST	91606	2	180B161  1197	2332002003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.18571	-118.41225	Plan check for PV roof mounted system. System size: 11kW with 44 modules and 3 inverters (3.0kW, 3.0kW and 5.0kW). Load calc attatch	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38302	19041-20001-08601	12317 N FINCH ST	90039	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM			PC Approved	07/05/2019 12:00:00 AM	PIN	34.3012906	-118.58563914	07/05/2019 Changes to an approved set of plans. Changes have been made to the roof plan.*****Original Work Description*****PV1.  Install 5.03 kW roof mounted grid tied PV system.  (15) AC modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38303	19041-10000-50984	7719 N RHODES AVE	91605	2	186B165    21	2307008002	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.21042	-118.40019	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 21 MODULES (LG335N1C-A5) , 21 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 7.035KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38304	13041-20000-32774	1100 S GLENDON AVE 19TH FLOOR	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.06074	-118.44418	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON 19TH FLOOR. 17000 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38305	16041-10000-29609	6255 W SUNSET BLVD #1050	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check Title 24 only office T.I. in existing space. Total area: 1,368 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38306	19041-10001-08327	6160 N LAUREL CANYON BLVD #B	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.18234	-118.39628	"Plan check only. Wet restamp and pereferate scanned copy of approved pereferated set to replace lost original set NEW FIRE ALARM SYSTEM IN BUILDING ""B""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38307	13041-20000-24164	13833 W VENTURA BLVD 204-205	91423	5	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.1487	-118.43426	TI, FIRST TIME TENANT OF OFFICE SPACES LOCATED IN SUITE # 204/205. FULL PLAN CHECK FOR POWER AND ENERGY. ORIGINAL SET OF PLANS FOR APPROVED LOAD UNDER APPLICATION #08041-20000-05790.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38308	16041-10000-32566	3201 N LACY ST	90031	1	142-5A221 272	5205002902	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	10/24/2020 12:00:00 AM	ADDRESS	34.08349	-118.21854	PC FOR NEW SUBMITTAL OF PLANS. PER APPLICANT, PLAN CHECKING AS NEW SUBMITTAL FOR NEW CODE CYCLES. TI FOR ANIMAL SHELTER. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38309	17041-10000-08377	966 W 46TH ST	90037	9	111B197   443	5018009010	RD3-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.00152	-118.29077	PC FOR SFD PV SYSTEM ROOF MOUNTED. USING CENTRAL INVERTER SYSTEM RATED 3.8KW AC. TOTAL OF 10 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38310	11041-20000-15479	21800 W BURBANK BLVD #225	91367	3	174B105    42	2146007122	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	09/14/2011 12:00:00 AM	ADDRESS	34.17267	-118.60262	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT TO 2ND FLOOR OF OFFICE BUILDING. PERMIT FOR NEW LIGHTING 277V CKT, NEW PANEL, AND 120V CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38311	18041-20000-11693	12050 N CARABELA CT	91326	12	216B109   286	2701083008	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29192	-118.58258	pv1install roof mounted pv system sized 4.8kw AC interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38312	16041-20000-09616	16739 W LUDLOW ST	91344	12	210B137   511	2683003016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.27121	-118.49691	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (19) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38313	14041-10000-35719	211 S AVENUE 20 1st floor	90031	1	138A221   176	5447024033	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.07213	-118.22001	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38314	13041-10000-00971	8118 S RAMSGATE AVE	90045	11	099B169  1077	4105023008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2013 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.96488	-118.38279	New 3.43 kw roof mounted PV1, installing micro inv. enphase 215	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38315	16041-10000-00225	12025 W VOSE ST #2	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.3952	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38316	13041-10000-17272	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM			PC Approved	06/28/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING IN AN EXISTING OFFICE BUILDING (TENANT IMPROVEMENT) SCOPE OF WORK IS LESS THAN 400 A. HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38317	15041-20001-11991	9509 N JELLICO AVE	91325	12	201B129   442	2755005005	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM			PC Approved	05/11/2015 12:00:00 AM	ADDRESS	34.24348	-118.51908	Expedited per customer request.PV1. Install roof mounted PV system sized 8.8 kW. Interconnected with main service panel. (44) Kyocera KU260-6 modules(1) Solaredge SE 3800(1) Solaredge SE 5000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38318	15041-20001-23821	8436 W 3RD ST Suites 700-701	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM			PC Approved	06/07/2016 12:00:00 AM	ADDRESS	34.07301	-118.37448	[[[ 6/7/16 CHANGES TO APPROVED SET OF PLANS. DELTA 5 CHANGES. CHANGES ARE CLOUDED. CHANGES TO LIGHTING LAYOUT IN CORRIDORS AND ADDITION OF NEW FIXTURES]]]]Plan check for power and lighting. Project site is the 7th floor of an existing commercial high-rise building. Use of site will be an outpatient surgery center. Procedures include outpatient surgical procedures which may include the use of anesthesia. Plans to be checked for OSHPD-3 requirements. New generator is being installed on the roof to provide emergency power to the essential eletrical systems. Total lighting area = 7,470 sq. ft.Note: Building plan check under application number 15016-20000-15535	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38319	17041-10000-35959	563 W 92ND ST	90044	8	094-5A201 152	6039016901	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	33.95292	-118.28438	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38320	18041-10000-40894	5733 N STANSBURY AVE	91401	4	174B153   418	2245028014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.17488	-118.44127	PC FOR ROOFTOP PV SOLAR, 26 MODULES, 9.36 KW SYSTEM, 1 INVERTER/OPTIMIZER INCLUDED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38321	12041-10000-11033	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	STARBUCKS KIOSK IN THE FOREVER 21 GLOBAL OFFICES.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38322	19041-10000-53469	3000 N NORTH MAIN ST	90031	1	135A223    26	5210024008	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	34.06589	-118.20993	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38323	16041-10000-26287	12563 W VENICE BLVD	90066	11	111B153   305	4246027028	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.00277	-118.43597	Full plan check to a single story commercial building. Change of use from wholesale auto parts to dental office. Installing two new panels, new power, and lighting. Total sqft = 1695  Building app ref #15014-10000-04781	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38324	18041-10000-36673	660 S FIGUEROA ST suite 1780	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Issued	12/05/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. HIGH RISE. SUITE 1780.   1864 SQ FT.BUILDING PERMIT # 18016-10000-29418	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38325	13041-20000-06137	8401 N VAN NUYS BLVD #A5	91402	7	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.22308	-118.44896	Change to lighting in an existing restroom in an existing retail building in the Panorama Mall.  Space #A5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38326	14041-20001-09458	5017 N LAUREL CANYON BLVD	91607	2	171B165  1025	2356004017	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.16172	-118.39681	(1/5/2017)CHANGES TO AN APPROVED SET OF PLANS.  ADDING PHASE CONVERTER FOR ELEVATOR.  PLAN CHECK FOR POWER ONLY.((600 AMP SERVICE. NEW CONSTRUCTION, 3-STORY APARTMENT WITH 4 UNITS.PLAN CHECK FOR POWER AND ENERGY.NEW 4 UNIT APTmodification for plan check extension filed 10-13- 15))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38327	16041-10000-44939	5905 N SEPULVEDA BLVD	91411	4	177B145   531	2243001033	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.17773	-118.46647	PC for energy only; Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 53,500.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38328	13041-20000-21860	5145 N TOPEKA DR PV-1	91356	3	171B121   357	2163025030	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.16447	-118.5467	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9KW USING 42 ENPHASE MICROINVERTER M215. NONSTANDARD PLAN. 4 STRINGS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38329	17041-10000-25661	4522 E BROWNE AVE	90032	14	142-5A229  37	5305009018	[Q]RE9-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.08651	-118.18991	TITLE 24 PLAN CHECK TO REPLACE EXISTING (7) FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA = 6325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38330	10041-10001-03589	1840 S CENTURY PARK EAST 1st. Floor	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			PC Approved	04/27/2010 12:00:00 AM	ADDRESS	34.06188	-118.41473	SUPPL. PLAN CHECK FOR CHANGES TO THE APPROVED SET DELTA 4. T.I. for a high rise building (Wells Fargo bank).  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38331	16041-10000-42227	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR A 3-STORY COMMERCIAL BUILDING. 543 FA DEVICES AND 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38332	12041-10001-26582			11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	04/05/2013 12:00:00 AM	PIN	34.05234345	-118.47066188	TI for a GYM. EPC for T24 and emergency lights. (B occupancy).  Changes made to previosly approved set.added additional lights..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38333	15041-10000-21003	1828 W WASHINGTON BLVD	90007	1	126B197   735	5075031022	[Q]CM-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.03978	-118.29808	TI TO AN EXISITNG COMMERCIAL BUILDING.  REMOVE HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQUARE FOOTAGE 3800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38334	13041-10000-19560	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.07594	-118.35916	Installation of a redundant 500 kVA power system (generator) for CBS stages 56 and 58.  Medium-voltage (4.8 kV) involved.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38335	13041-10000-21936	13211 N LA TIERRA WAY	91342	7	225B165    19	2580018***	RD6-1, T, Q	North Valley				1061.12	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	34.31273	-118.40393	PV1.  Install 3.45 kW AC roof-mounted solar array, interconnect into main service panel.  Standard plan.  {Microinverters: Enphase M215-60-2LL} {16 modules: REC 250 PE}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38336	19041-10000-11268	4143 W DON MARIANO DR	90008	8	114B181   588	5026004008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.00642	-118.34367	PV1. NEW ROOF TOP SOLAR SYSTEM WITH BATTERY BACK UP. THE SYSTEM CONSIST OF 12 MODULES (Q-CELL 305) WITH A CENTRAL INVERTER (DELTA SALIVIA 3.8) AND A 13.5KWH TESLA POWERWALL. SYSTEM SIZE IS 3.6 KWac AND 3.66KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38337	11041-10000-15104	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	10/19/2011 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	NEW FIRE ALARM SYSTEM FOR MIXED-USE BUILDING, 6-STORY R-2 OCCUPANCY WITH 3 SUB-PARKING LEVELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38338	18041-10000-36611	7001 N SOPHIA AVE	91406	6	183B137   268	2224001901	M1-1, [Q]M1-1, [Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.19773	-118.48731	New panel, power, and lighting for commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38339	13041-10000-21128	12643 W SHERMAN WAY UNIT A	91605	2	183B161    12	2324003046	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.20136	-118.40837	REMODEL INSIDE OF EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38340	15041-10000-03353	380 W WORLD WAY TBIT/BHS	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	FOR BHS RENOVATION, PANEL BOARDS LOADS SUPPLIED FROM 2 EA 5000A SWBD  ARE REVISED-FOR A PANEL THE LOAD CAN BE REDUCED FOR ANOTHER PANEL THE LOAD IS REMOVE.PANEL SCHEDULES ARE REVISED AND LOAD CALCULATION FOR EACH SWBD IS NOTED ON THE SINGLE LINE DIAGRAMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38341	17041-10000-38818	13778 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.30942	-118.43324	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 17150 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38342	19041-20000-38446	4804 W OAKWOOD AVE	90004	4	138B193   311	5522033016	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			09/24/2019 12:00:00 AM	01/05/2021 12:00:00 AM		Permit Finaled	06/17/2022 12:00:00 AM	ADDRESS	34.07712	-118.31161	Full plan check for energy and power. New 1600A service and panels with lighting and power loads. T24 is included. Total square footage = 30364 sfPer building permit 18010-10000-04013(TOC-Tier 2 )New 4-story, 30-unit, Affordable housing apartment building (per TOC guidelines Tier 2) with 1-level above grade parking and 1 level of subterranean parking garage	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38343	18041-10000-34796	7855 N HAYVENHURST AVE	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.21329	-118.49262	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38344	13041-10000-03503	18837 W NAU AVE	91326	12	213B121   408	2871006001	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.28009	-118.54367	PLan check for PV1 4.905K roof-mounted photovoltaic system. Transformerless. Permit to include service panel upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38345	10041-10000-24423	6990 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	09/10/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	"INSTALLATION OF ROADWAY LIGHTING FIXTURES NEAR  TAXI WAY ""S"". ; 100A 1PH 120/240V SERVICE PROVIDED; 5EA FIXTURES WILL BE SUPPLIED FROM UNDERGROUND CONDUCTORS AND 5 EA WILL BE SUPPILED FROM OVERHEAD CONDUCTORS. TITLE 24 FOR EXTERIOR LIGHTING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38346	14041-20001-12377	9833 N SHOSHONE AVE	91325	12	201B129   124	2755010019	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	34.24954	-118.51846	Fee for expedite only.*****Roof mounted PV system with system size 11.54KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38347	14041-20000-11793	15931 W VOSE ST	91406	6	183B141   296	2224008045	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.19855	-118.48039	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.75KW INTERCONNECTED WITH MAIN SERVICE PANEL.(1) SOLAREDGE 5000A TRANSFORMERLESS INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38348	15041-10000-20803	5900 W WILSHIRE BLVD STE. 2750	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.06237	-118.35809	TI TO AN EXISING HIGH RISE BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN 27TH FLOOR.  PLAN CHECK FOR ENERGY ONLY.  TOTALL SCOPE 5313.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38349	12041-20001-23750	342 S LA BREA AVE	90036	4	135B181   300	5507008018	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM			PC Approved	11/14/2012 12:00:00 AM	ADDRESS	34.06762	-118.34382	T-24 lighting plan check for remodeled space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38350	19041-10000-23522	6501 S CRENSHAW BLVD	90043	8	105B185  1252	4006018001	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	07/13/2021 12:00:00 AM		Permit Finaled	06/20/2023 12:00:00 AM	ADDRESS	33.98038	-118.33106	FULL PC FOR A NEW 1600A SERVICE (120/208 3P 4W) THAT FEEDS A NEW 1600A MAIN SWITHBOIARD THAT CONTAINS SUBPANELS FOR ALL ASSOCIATED HOUSE LOADS. SERVICE ALSO FEEDS TWO 600A MULTI-METERING CENTER WHICH CONNECT TO SWTATE APPROVED DWELLING UNITS. NOTE THERE IS ALSO A 125KWGENERATOR ON SITE FOR EMEGRENCY PURPOSES. TOTAL AFFECTED AREA IS 37,194 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38351	17041-20000-23585	12723 W WENTWORTH ST	91331	6	198B161   319	2629027017	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.23711	-118.41145	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR TWO VESTIBULES. 291 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38352	14041-20001-06548	14300 W BEAVER ST	91342	7	219B153   274	2507024005	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.29738	-118.44473	((EXPEDITE FEES))PV1 ROOFTOP TRANSFORMERLESS SYSTEM WITH SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38353	13041-20000-01967	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.25052	-118.51258	New 8.58kw rooftop mounted PV system on an existing single family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38354	13041-10000-01896	17856 W VICINO WAY	90272	11	126B117   231	4416017015	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.04288	-118.56413	PV1 4.65KW 16 modules. 1 story. MODULE SUNPOWER SPR-327NE INV SPR5000P transformless	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38355	19041-10000-22960	3360 S BEETHOVEN ST	90066	11	114B149   547	4244006032	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.00857	-118.44786	[e-plan] PV1. Changes To Approve Set1) DC disconnects were moved from the E to the W end of the wall.2) An additional interior PV AC disconnect was added.The changes are clouded.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38356	17041-20000-20359	7716 N BALBOA BLVD	91406	6	189B133   905	2205008029	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Issued	06/16/2017 12:00:00 AM	ADDRESS	34.21083	-118.50093	Plan check for power only. Replacing damaged 400A service due to LADWP transformer failure. Removing existing gutter and installing a 400A main service panel to reconnect existing unit panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38357	14041-20000-07790	14053 N SADDLE RIDGE ROAD	91342	7	228B141    24	2582033043	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.32559	-118.48252	Roof mounted PV system with Optimizers and transformerless inverter.  System size 3.8KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38358	12041-10000-28952	3303 W WILSHIRE BLVD	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.06195	-118.29439	GENERATOR UPGRADE 85 KVA TO 125 KVA FOR EXISTING HIGHRISE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38359	13041-10000-33881	1299 S MAPLE AVE	90015	14	124-5A209 172	5145027044	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.03522	-118.25745	Plan check for T24 only. Remove HID light fixtures and replace with new fluorescent fixtures in a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38360	15041-20000-16323	936 S OLIVE ST UNIT 346	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #19 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38361	11041-10000-02134	940 W 35TH ST	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Closed	08/16/2012 12:00:00 AM	ADDRESS	34.02309	-118.28755	Temporary 600Amp Service for a new building at USC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38362	18041-30000-07176	2029 S CENTURY PARK EAST 5th Floor-rr	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing space men and women restroom on 5th floor. Total area: 410 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38363	18041-20000-16420	14855 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29448	-118.45513	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38364	19041-20000-37917	5913 1/2 W WILLOUGHBY AVE	90038	13	144B189   997	5534028016	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.08722	-118.32489	PV2. INSTALL 3.700 KW DC SOLAR SYSTEM WITH (10) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38365	18041-10000-37724	4850 W HOLLYWOOD BLVD	90027	13	147B197   269	5543009021	C2-1D, RD1.5-1XL	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	07/29/2020 12:00:00 AM		Permit Finaled	08/17/2023 12:00:00 AM	ADDRESS	34.10155	-118.29595	PLANCHECK FOR POWER AND ENERGY.  6 STORY TYPE IIIA MIXED USE APARTMENT BUILDING (101 UNITS) . 2500A  480/277 SERVICE.  [[[[PLANCHECKER TO VERIFY FEES]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38366	17041-30001-41998	8521 N FALLBROOK AVE	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.22368	-118.62797	02-01-2018 Changes to an approved set of plan. Changes include replace different lighting fixture models remove F3 fixture and replace F2 fixture with different model and relocate receptacles. Changes has been clouded as delta 2 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38367	15041-10000-26865	1277 N WESTERN AVE	90038	13	144B193   105	5537001003	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	PIN	34.0946175	-118.30956063	Full pc for power and energy to a new commercial, starbucks, bldg. 600amp service 120/208 3phase 4wire system. Total sq. ft. 1391Fees per applicant. May need to readjust.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38368	14041-10001-00984	1225 N BEVERLY ESTATE TER	90210	5	144B157   160	4356012004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.09311	-118.42848	Expedited RSES plan check per applicant request. {{PV1, Install 13.39 kW DC roof-mounted solar array for a two story house, interconnect with existing service panel. (2) Inverters: Fronius IG PLUS V 7.5 and IG 4000 NEG. (57) modules: SHARP NU-235F1.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38369	10041-10000-01450	12301 W WILSHIRE BLVD #205	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	01/28/2010 12:00:00 AM		Permit Finaled	03/16/2010 12:00:00 AM	PIN	34.04277409	-118.46969044	Plan check power and energy for a TI in a dental office (suite 205).  Exit signs are exsiting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38370	19041-20000-13867	3024 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38371	11041-10000-14520	14006 W RIVERSIDE DR #245A	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I.  New Fossil store to occupy an existing retail space.  Plan check is for energy only using Tailored method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38372	19041-10000-14245	10451 N LARWIN AVE #5	91311	12	207B101   243	2723011***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Apartment			04/18/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.26061	-118.6139	Plan check for a 6KW AC / 6.57KW DC  PV2 roofmounted system with (1) inverter, (18) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38373	18041-10000-19976	12885 W NORTH SEAGLASS CIR	90094	11	102B157   398	4211037143	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.9741	-118.42006	Install (1) Tesla ESS, this plan ties to E18LA02429 (PV)<<E18LA02429 : New PV1 rooftop Solar system 7.6 kW AC/ 8.125 kW DC with ESS (on separate application#), (25) modules with optimizers, (1) inverter, (1) 200 A load center>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38374	14041-20001-18770	106 N POINSETTIA PL	90036	5	138B181   812	5512020021	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2014 12:00:00 AM			PC Approved	09/04/2014 12:00:00 AM	ADDRESS	34.07391	-118.34849	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof mounted solar array on SFD. Three strings to combiner. System Size: 6kW.(1) SMA SB6000TL-US-22 transformerless inverter(18) SunPower SPR-X21-345 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38375	18041-20000-42881	501 S EUCLID AVE	90063	14	124-5A225 195	5185016004	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.03532	-118.20453	Plan check for a PV1 roof-mounted PV system. System size is 6.09 kWdc/6 kWac and consists of (1) inverter and (21) modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38376	14041-10000-07619	18021 W CHATSWORTH ST #16	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.26491	-118.52556	PLANCHECK FOR T24 ENERGY. Tenant Improvement for existing retail space. 4250 SQFT, EMERGENCY LIGHTING. NEWLY CONNECTED LOAD <400 AMPS. NO CHANGE IN OCCUPANCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38377	15041-20000-11269	6360 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.18619	-118.5972	Plan check for power only.  Installation of two new 75 kVA transformers feeding four new panels in existing highrise hotel.  Loads will be feeding new guestroom lighting and refrigerators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38378	12041-10000-29861	10913 N COLLETT AVE	91344	12	210B141   981	2667007002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.26857	-118.48378	PV1.  4.335 KW (DC) roof mounted PV system for a single family residence.  Installing 17 modules and 17 ENPHASE M215 micorinverters.  Applicant is using the standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38379	13041-20001-06945	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	Changes to approved set of plans. Changes clouded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38380	19041-10001-02750	5359 E VALLEY BLVD	90032	14	139-5A237  90	5220033023	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	11/20/2023 12:00:00 AM	ADDRESS	34.07473	-118.16674	"REVISION OF AN APPROVED SET FOR AN INDOOR NURSERY. SCOPE IS UNDER DELTA 4 ONLY. SCOPE INCLUDE UPGRADING SWITCHBOARD SIZE FROM 4000A TO 5000A, CHANGING LOAD CALC AND UPDATING SOME OF THE PANEL SCHEDULES ORIGINAL SCOPE ""NEW INDOOR NURSERY. NEW SERVICE: 4,000 AMP, 277/480V, 3PH. AREA: 31,136 SQR FT.BUILDING PERMIT: 18016-10000-40987 ."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38381	09041-10001-11020	2130 E 1ST ST	90033	14	127-5A223 122	5183008901	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.20	Electrical	Electrical	Public Safety Only			09/20/2011 12:00:00 AM			PC Approved	09/20/2011 12:00:00 AM	ADDRESS	34.04433	-118.21291	REVISIONS TO APPROVED SET OF PLANS-REARRANGE SOME FA DEVICES DUE TO CHANGES IN ROOMS LAYOUTS((((((((NEW FIRE WARNING SYSTEM FOR A 2-STORIES COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38382	17041-10000-18032	110 W SAN FERNANDO ROAD	90031	1	139-5A219 143	5447014003	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Info Complete	05/31/2017 12:00:00 AM	ADDRESS	34.07462	-118.2212	RESTAURANT TI. LESS THAN 100 OCCUPANTS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38383	18041-20000-17450	2483 W LINDSAY LANE	90039	4	148-5A207  58	5439016019	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.10242	-118.2618	Plan check for the addition of (1) Tesla PowerWall onto an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38384	14041-20001-14275	2530 N VASANTA WAY	90068		154-5A189 494	5585010001							Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	PIN	34.11563297	-118.3237399	Expedited plan check per applicant request.  PV1.  Install 5.3 kW roof-mounted utility-interactive PV system.  Transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38385	11041-10000-27490	2869 W PICO BLVD	90006	1	129B193  1232	5080028013	C2-1	Central	Wilshire	Olympic Park		2132.02, 2212.10	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM	01/05/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.04737	-118.30235	CHANGE OF USE TO (N) OFFICE FROM (E) WAREHOUSE; TENANT IMPROVEMENT : NEW CIRCUITS AND LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38386	13041-10000-26337	909 N AVALON BLVD	90744	15	030B205    88	7423004017	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Info Complete	09/24/2013 12:00:00 AM	ADDRESS	33.78153	-118.26274	remodeling existing retailstor;using existingservice, replacing panelboards and wiring	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38387	12041-20000-09578	15928 W VENTURA BLVD	91436	5	168B141   621	2283010033	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM			PC Approved	04/26/2012 12:00:00 AM	ADDRESS	34.15566	-118.48041	Plan check for energy only. 553 conditioned sqft. Single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38388	17041-20000-41317	12011 W WILSHIRE BLVD	90025	11	129B145  1047	4265014105	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			Corrections Issued	11/15/2017 12:00:00 AM	ADDRESS	34.04567	-118.46582	Tenat improvement to (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38389	14041-10000-34304	541 S SPRING ST	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.04657	-118.2507	This is a low rise commercial juice bar. title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38390	18041-10000-13948	8977 N GLENOAKS BLVD	91352	6	195B173   168	2408032034	M1-1-CUGU, P-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.23189	-118.36889	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38391	12041-10000-02674	905 E 8TH ST	90021	14	124-5A213  77	5146029039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.03645	-118.24647	INSTALLATION OF 1600A  SERVICE FOR FUTURE 2-STORIES OFFICE BUILDING WHICH IS TO BE OCCUPIED BY A SINGLE TENANT; TENANT WILL SUBMIT PLANS FOR COMPLETE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38392	14041-10000-10695	610 S LEVERING AVE 1-18	90024	5	135B149   341	4363011010	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			04/23/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.06654	-118.45286	new fa for 18 unit apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38393	13041-10000-04464	333 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   594	2424044021	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			02/21/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	ADDRESS	34.13838	-118.35964	RENOVATION OF EXISTING POOL DECK. T24 ONLY FOR NEW LIGHTING OF POOL DECK AND BAR AREA. TOTAL AREA 11915 SQ FT. PC FOR T24 COMPLIANCE, PERMIT TO BE ISSUED BY PC COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38394	17041-20003-33842	6108 N LAURELGROVE AVE	91606	2	177B165   480	2333006061	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM			PC Approved	05/03/2018 12:00:00 AM	ADDRESS	34.18149	-118.40074	05-03-2018 Changes to an approved set of plan. Changes include update single line diagram to reflect new design. Plan check only Permit refer to Application Number: 17041-20000-33842	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38395	16041-10001-36099	901 E 12TH ST	90021	11	123A211    87	5132014001	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.03208	-118.24959	10/26/16Plan check for a lost set of plans. Plan check only.Note: Permit shall be pulled under original application 16041-10000-36099(((((((((T-24, PC for energy only. Interior tenant improvement and exterior alterations to existing commercial building.  Change of use from part warehouse to Office space. Total affected area is 9825. B#16016-10001-01053	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38396	14041-20000-02704	12073 W PIERCE ST	91342	7	213B165   476	2531022001	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.27997	-118.39621	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.4KW AC USING MICROINVERTER USING STANDARD PLAN. USING ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38397	17041-20000-02108	281 N BENTLEY CIR	90049	5	138B149    66	4366004018	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.07702	-118.45744	Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (69) modules, and (1) load center.$0 permit fee per State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38398	12041-10000-04367	415 E ADAMS BLVD	90011	9	120A207   161	5127011033	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Apartment			02/27/2012 12:00:00 AM	04/06/2012 12:00:00 AM		Permit Expired	04/30/2014 12:00:00 AM	ADDRESS	34.02335	-118.26491	Plan check 36.6KW roof mounted photovoltaic system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38399	18041-10000-25988	17400 W VICTORY BLVD	91406	6	177B129     8	2229033900	A2-1-RIO, OS-1XL-RIO	South Valley	Reseda - West Van Nuys	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.18631	-118.51407	TI IN AN EXISTING OFFICE AREA. CONVERTING AN EXISTING CONFERENCE ROOM TO (3) OFFICE SPACES. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38400	13041-10001-12357			12	210B109   174	2707025043	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	PIN	34.26984303	-118.58021424	request for plan check by inspector. PV1 9kw XFMR INV. 1 STORY. nonSTD. ROOFMOUNT. [ 2  INV:  SMA america-sb6000US and sb3000us ][36 MOD: TRINA {TSM-250PA05.08}]INSTALLATION OF PHOTOVOLTAIC SYSTEM, 36 MODULES,  9.0 KW AND 225-AMP PANEL UPGRADE.  Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38401	18041-20000-22864	11900 N MASON AVE	91326	12	216B109    26	2701002915	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	04/28/2022 12:00:00 AM		Issued	04/28/2022 12:00:00 AM	ADDRESS	34.28909	-118.58364	Plan check for power and energy. Project site is (4) new buildings: (2) bathrooms, (1) maintenance building, and (1) pavilion. Work includes a new 1,600-amp service and a total lighting area of 62,640 sq. ft.Note: Building applications have been filed under 17010-20000-03818/03821.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38402	18041-10000-42549	1243 S OLIVE ST C119	90015	14	126A207   200	5139023038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	34.03859	-118.26331	Change to approved set by reconfiguring the single line and modifying the panel schedule. All changes under delta-3 only.(((PC FOR FIRST TIME TENANT FOR A DOG SPA (CHANGE OF USE FROM RETAIL TO DOG GROOMING AND CARE). THIS IS A HIGH- RISE BUILDING. SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 7531 SQ.FT .B#17016-10000-18903 )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38403	15041-20000-23689	2829 W HYANS ST 1-12	90026	13	138A203   152	5156016017	R3-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			07/24/2015 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.07331	-118.27888	Plan check for power and Title-24 (energy).  Total area = 19,564 sq. ft. (indoor) + 1,000 sq. ft. (outdoor)  New 800 A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38404	12041-10000-24105	1931 N BRONSON AVE	90068	4	150A191   124	5586014071	C1-1D	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/09/2012 12:00:00 AM	ADDRESS	34.10604	-118.31819	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38405	14041-20001-05999	14745 W MACLAY ST	91345	7	210B149   314	2664011061	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM			PC Approved	03/16/2014 12:00:00 AM	ADDRESS	34.27425	-118.4536	((expedite fees))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38406	17041-10001-19757	814 S BROADWAY	90014	14	127-5A209 160	5144016064	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM			PC Approved	09/28/2017 12:00:00 AM	ADDRESS	34.04325	-118.25495	PC FOR CHANGES TO APPROVED SET UNDER DLETA 1. SCOPE INCLUDES CHANGES TO ENTRANCE FIXTURES, FIXTURE SCHEDULE AND REVISION TO T-24 FORMS.THIS IS PLAN CHECK ONLY!!PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38407	14041-20002-13145	20226 W SEPTO ST	91311	12	201B113   112	2741017015	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.25077	-118.57424	Changes from previously approved plans.  Down sized PV system size from 7.4KW to 5.1KW.  Note: Permit is under a original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****Roof mounted PV system with Optimizers and tranformerless inverter.  System size is 7.4KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38408	17041-10000-11633	15101 W SAN FERNANDO MISSION BLVD	91345	7	210B145    79	2664001022	A2-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.27287	-118.45995	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 295550 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38409	16041-30000-00487	14031 W VICTORY BLVD Apt 3	91401	2	180B153  1077	2238025005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			01/07/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.18683	-118.43882	Installation of new roof mounted PV array on existing apartment building for Apt 3.  System consists of a 3 kWAC inverters with (9) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38410	19041-20000-42783	4563 W SANTA MONICA BLVD	90029	13	144B197   672	5542027029	C2-1D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	11/20/2020 12:00:00 AM		Permit Finaled	02/16/2021 12:00:00 AM	ADDRESS	34.09101	-118.28824	Plan check for service upgrade to 600A, with (3) new panels with no new load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38411	09041-10002-00601	1375 W ADAMS BLVD	90007	8	123B197   881	5055004026	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM			PC Approved	03/03/2010 12:00:00 AM	ADDRESS	34.03295	-118.29107	Add and delete luminaires from approved Lighting plan. Plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38412	18041-10000-29994	424 W PICO BLVD	90015	14	126A207   179	5134017004	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Issued	09/10/2018 12:00:00 AM	ADDRESS	34.03913	-118.26523	PC FOR FIRST TIME TENANT IN RETAIL 2 SPACE.  TOTAL AFFECTED AREA 1702 SQ.FT SCOPE INCLUDES NEW EQUIPMENT PANELS AND RECEPTACLES ( LIGHTS ARE EXISTING FROM CORE AND SHELL).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38413	11041-10006-12353	620 W 2ND ST	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.0545	-118.25027	NEW ELEVATOR AND CIRCUITS ARE ADDED TO A PERMITTED SET OF PLANS. PERMIT WAS OBTAINED ON ORIGINAL PLAN BUT WORK HAS NOT BEEN STARTED OM ORIGINAL PLANS11041-10000-12353NEW PARKING STRUCTURE / MUSEUM BUILDING (	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38414	14041-20000-35864	17383 W SUNSET BLVD	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.03917	-118.55529	ADDING EXTERIOR WALKWAY LIGHTING TO AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38415	16041-30000-05809	3965 N CARPENTER AVE	91604	2	162B169   278	2369016049	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Apartment			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.1422	-118.39129	Installation of fire alarm system in new 6 unit 4 story apartment building.  Total system size = 43 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38416	19041-10000-04867	1640 S SEPULVEDA BLVD #460	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.04838	-118.44468	FULL PC PWR AND ENERGY FOR TENANT IMPROVEMENT TO (APPROX. 4450 SFQT) OFFICE SPACE; WORK TO INCLUDE NEW NON-BEARING PARTITIONS, CEILING AND FINISHES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38417	12041-10000-09257	9742 N CACTUS AVE	91311	12	201B097    91	2724010016	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2012 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	ADDRESS	34.24737	-118.62148	New 9.36kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38418	16041-20000-08502	6260 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Expired	04/11/2018 12:00:00 AM	ADDRESS	34.18497	-118.60418	Plan check for energy only. Install new light fixtures under solar canopy on rooftop of parking garage. 103,051sqft hardscape.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38419	17041-20004-28602	11433 W ALBERS ST	91601	2	174B169  1079	2350007049	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			02/22/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.17056	-118.38016	changes to an approved set of plans.  changes to reflect field conditions. this is plan check only.changes noted delta E only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38420	19041-10000-09094	445 S FIGUEROA ST STE 2530-2550, 2570	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLAN CHECK FOR T-24 ONLY FOR Suite 2530 (1,789 SF), 2550 (1,504 SF), and 2570 (2,038 SF) and replace finishes in corridor.  SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4345.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38421	14041-20000-31134	14435 W HAMLIN ST 106D	91401	6	180B149   582	2237014020	[Q]C1-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Info Complete	12/08/2014 12:00:00 AM	ADDRESS	34.18885	-118.44771	Plan check for power and energy. TI for existing medical office. Chiropractor. New indoor lighting and receptacles. permit already issued under application #14041-30000-29927, this application is plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38422	15041-10000-14231	600 WORLD WAY # 637-639	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM			PC Info Complete	05/12/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24 FOR TWO KITCHEN SPACES IN LAX, TOTAL SQ. FT. 1190THIS IS PLAN CHECK ONLY. FEES PAID UNDER APPLICATION NUMBER 15041-90000-20883.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38423	16041-20001-30708	1234 W 7TH ST	90017	1	130-5A207 158	5143009003	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	10/17/2016 12:00:00 AM	ADDRESS	34.05185	-118.26696	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar array on commercial building. 20kW ungrounded system (10+10).(80) 340W pv modules. Interconnecte with 1200A MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38424	13041-10001-00572	7122 W BEVERLY BLVD	90036	5	138B181   432	5513002032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/21/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	ADDRESS	34.07599	-118.34481	MODIFICATIONS TO APPROVED SET OF PLANS UNDER PLAN CHECK NUMBER 13041-10001-00572. PLAN CHECK ONLY. REMINDER: ANY TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE PLAN CHECK STAFF AT THE ELECTRICAL PLAN CHECK COUNTER.  **********************************ORIGINAL 13041-10000-00572 DESCRIPTION: T.I.  Exisiting Starbucks.  Modification to the interior lighting.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38425	12041-20000-28817	12920 S FIGUEROA ST	90061	15	081B201   316	6132015054	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	33.91479	-118.28252	Change to lighting, receptacles, loads, new service and  panels for an existing Medical/Dental Office.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38426	14041-10000-30083	1365 E 15TH ST	90021	14	121-5A213 233	5130011018	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.02614	-118.24603	Energy plan  check only. New ware house with 400amp service. Condition floor area: 1,013 sq ft. Uncondition foor area: 4337 sq ft. ( Per F.Y)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38427	15041-10000-15297	200 WORLD WAY UNIT # 225	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	"T24 ONLY. INSTALLATION OF ILLUMINATED SIGNAGE NOT VISIBLE FROM ROW. COPY TO READ ""SLAPFISH"". TERMINAL 2. TOTAL AREA 3.09 SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38428	17041-20000-15785	7225 W MELROSE AVE	90046	5	141B181   547	5525011033	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Info Complete	04/27/2018 12:00:00 AM	ADDRESS	34.08363	-118.34704	Change of use from office to medical office building and remodel.  New 600A  120/240V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38429	13041-10000-12105	7530 N GLENOAKS BLVD	91504	2	186B181   214	2401042008	(Q)C1.5-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.20763	-118.34265	PLAN CHECK FOR FIRE ALARM. REPLACEMENT OF FACP AND ADDITION OF 18 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38430	15041-10000-03996	9950 N REMMET AVE	91311	12	204B105   817	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.25148	-118.60031	T24 only. remove hid light fixtures and replace with LED fixtures. total area 4336 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38431	14041-10000-03154	8769 N RANCHITO AVE	91402	6	195B153   832	2638013013	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.22943	-118.43949	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(18)modules: {Trina {TSM-250PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38432	13041-10000-13706	12400 N RALEIGH CT	91326	12	216B113   215	2701048014	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Expired	07/01/2015 12:00:00 AM	ADDRESS	34.29127	-118.5731	PV1 7.59kw XFRMless. 2 STORY HOUSE. nonSTD. ROOFMOUNT.  [ 2 INV: solaredge SE3800A-US] [ 33 MOD: yingli YL230-29b with optimizers]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38433	15041-20000-26370	1550 N GOWER ST	90028	13	147A189    19	5545008020	C4-1	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.09906	-118.32216	P.C for T-24 Energy only. Total area: 4364 sq.ft. TI to a studio on a low rise bld.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38434	15041-10000-07250	1460 W 27TH ST	90007	8	123B197  1350	5054032011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	34.03028	-118.29351	PV2, INSTALL 24.5 KW AC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE TO MAIN SERVICE PANEL.(92) MODULES ,(5) INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38435	17041-30000-43098	4216-4218 W JEFFERSON BLVD	90016	8	120B197   646	5040021004	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.02536	-118.34231	Plan check for core and shell of the building 600A service for 2 units office space.  Total area: 8000 sq ft. B#17014-30000-06176	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38436	13041-20000-27741	560 N AMALFI DR	90402	11	123B129   114	4408021005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.03601	-118.51291	PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 7.0KW. 28 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38437	15041-30000-36948	10505 W SARAH ST	91602	4	168B177   798	2420032037	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM			Reviewed by Supervisor	11/16/2015 12:00:00 AM	ADDRESS	34.15405	-118.35934	Plan check for power only.  Remodel of existing single family dwelling.  Complete electrical renovation including 800 A service upgrade.  New switchgear with 6 new subpanels and new wiring throughout.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38438	15041-10001-43517	8717 N DARBY AVE	91325	12	195B125   809	2769025011	M1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.2292	-118.53371	Revision to approved (permitted) set due to:(1) Change of engineer (letter for change of engineer is attached)(2) Change of design (power and lighting) due to floor plan change, single line diagram remain the same.(3) Adding new circuits. HVAC equipment and new sound equipment.Permit# 150412000043517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38439	16041-10000-09719	815 S HILL ST	90014	14	127-5A209  75	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM			PC Info Complete	03/21/2016 12:00:00 AM	ADDRESS	34.04417	-118.25633	TI to an (E) Restaurant. Install lighting. PC for T-24 only. Total area: 1,610 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38440	14041-10000-10738	11237 N COMETA AVE	91331	7	210B165   206	2532026008	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.2742	-118.39959	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. USING STANDARD PLAN. TOTAL SYSTEM SIZE5.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38441	12041-20000-12121	2047 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.03973	-118.44287	New circuits for remodele of restaurant.  Plan check was for energy compliance only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38442	12041-10000-22685	4940 N TOPEKA DR	91356	3	168B121    74	2176029024	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.16	-118.54705	New 11.27kw ground mounted photovoltaic system for an existing single-family residence.  System is an ungrounded system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38443	19041-20000-41178	11345 N MONTGOMERY AVE	91344	12	210B141    56	2666016009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.2761	-118.48266	PV roof mounted system, PV system size: 11.7KW with 36 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38444	17041-10003-04622	20059 W RINALDI ST BLDG C1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.2756	-118.57118	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  7, 25, 28, & 29. CHANGES INCLUDE RELOCATING SITE/LANDSCAPE LIGHTING, ADDING EXTERIOR LIGHTING, AND REVISING TITLE 24 CALCULATIONS.NOTE: PLAN CHECK ONLY, PERMIT UNDER ORIGINAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38445	15041-20000-03059	1196 S LORENA ST	90023	14	120A225   303	5190016037	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Expired	06/08/2017 12:00:00 AM	ADDRESS	34.02163	-118.20456	PC FOR TI TO RETAIL SPACE. ENERGY ONLY. T24. NO CHANGE IN AREA OF SPACE OR SPACE TYPE. LESS THAN 85% OF WATTAGE DENSITY. OK FOR MULTI LEVEL CONTROLS. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38446	17041-20000-11935	8510 N KEOKUK AVE	91306	3	192B113   180	2781015010	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	05/06/2017 12:00:00 AM	ADDRESS	34.22489	-118.57382	pv1install roof mounted pv system sized 4.4kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38447	14041-10000-10134	910 S LINCOLN BLVD	90291	11	111B145   877	4243004033	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	33.99868	-118.46193	Plan check for power and energy for remodel of existing Ralph's store.  Total new/revised connected load exceeds 400 amps. Plan check includes new starbucks within Ralph's store	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38448	15041-10000-09786	3435 W WILSHIRE BLVD 16TH FL	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.06194	-118.29866	ALTERATIONS IN THE CORRIDORSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38449	17041-10000-37159	360 E 2ND ST Patio 2nd-Floor	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	Installing new luminaires on patio / amenity deck on the 2nf floorplan check is for title 24 and 1 ea emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38450	12041-10000-15407	12100 W VENTURA BLVD	91604	2	162B165   158	2369014001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			Verifications in Progress	10/24/2012 12:00:00 AM	ADDRESS	34.14333	-118.39562	Plan check for power and energy. CVS. 15000 sqft. Occupancy load of approx 550.INTERIOR T.I.   NEW CHECK OUT COUNTERS & PHOTOLAB COUNTERS; UPGRADE PHARMACY; PER ENGINEER'S DESIGN, REPLACE HVAC ROOF TOP UNITS; RESTROOM UPGRADES; REPLACE REACH-IN COOLERS AND SPANDREL GLASS FACING VENTURA  BL. NO ADDED FLOOR AREA. REHAB AS NECESSARY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38451	16041-20000-14364	217 E 8TH ST	90014	14	127-5A211 351	5145003089	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.04155	-118.25168	Plan check for energy only. TI - Change of use from retail to restaurant. New lighting (incl. emergency). 2,161sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38452	17041-10003-22182	1035 N SWARTHMORE AVE 1-105	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM			PC Info Complete	08/10/2018 12:00:00 AM	ADDRESS	34.04825	-118.52512	"7/6/18 DELTA ""3"" CHANGES ONLY TO APPROVED SET. CHANGES INCLUDE REVISION TO LIGHTING, T24, ADDITION OF CIRCUITS, PANEL AND RELOCATION OF LOADS.PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER DELTA  ONE AND TWO. SCOPE OF DELTA 1 INCLUDES -  SPATIAL RECONFIG IN BASEMENT FLOOR AND POWER RELOCATION IN SPACE SOME CIRCUITRY ADDITION ( SOME KITCHEN EQUIP. TO BE CHANGES).SCOPE OF DELTA 2 INCLUDES - CHANGES TO LIGHTING AND REVISIONS TO T-24 FORMS. SOME REVISIONS TO CIRCUITS AND LCP."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38453	11041-10000-26975	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.14246	-118.2705	T.I. to restroom area.  Install general lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38454	13041-10000-35638	8941 N TAMPA AVE	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.23285	-118.55413	core and shell only for Ulta retail store. Separate permit for electrical to be pulled by tenant.PLANCHECK FOR POWER AND ENERGY FOR DEMOLITION FOR RETAIL STORE.  EXISTING RETAIL .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38455	17041-20001-42996	10807 W BELLAGIO ROAD	90077	5	138B149    26	4362006006	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.07832	-118.45299	expeditepv1install roof mounted pv system with battery back up interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38456	14041-10000-29097	1823 W ADAMS BLVD	90018	8	123B193   588	5058020008	C1-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Expired	11/14/2016 12:00:00 AM	ADDRESS	34.03291	-118.30388	PV1.  Install 7.6 kW roof-moutned, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38457	17041-10000-16059	1640 S SEPULVEDA BLVD #500	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.04838	-118.44468	TI TO OFFICE SPACE. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38458	19041-10000-06523	369 N RIDGEWOOD PL	90004	4	138B189   138	5522028004	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.07785	-118.31471	ADD A NEW 13.5 KWH POWER WALL BATTERY SYSTEM TO THE SOLAR SYSTEM ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38459	19041-30000-10137	2029 S CENTURY PARK EAST 2nd Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is a portion of the 2nd and 3rd floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 14,804 sq. ft.Note: Building permit has been issued under 19016-10000-00807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38460	16041-10000-45833	4411 S 11TH AVE	90043	8	111B185   119	5013022030	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	34.00327	-118.32948	Energy plan check for a new fire pump room. Total area is 262 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38461	19041-20000-40430	1900 S AVENUE OF THE STARS 1700	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.05979	-118.41671	Tenant Improvement P.C for title-24 for an office in a high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38462	16041-20001-34044	6433 N DUNLO PL	91307	12	180B085    87	2032005008	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	ADDRESS	34.18731	-118.66009	10/03/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta A. Module count has been reduced to (31) modules and inverter size has been reduced to 7.6 kWac.*****Previous Work Description*****PV1.  Install 8.2 kW rated PV system.  (38) modules with (1) 8.2 kW rated central inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38463	17041-10001-41424	11203 W NATIONAL BLVD	90064	5	120B157   244	4251002022	C2-1VL	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.02745	-118.42919	Revision to approved set, revise luminaire description (tag A) to match existing installation. This is plan check only, permit is covered under permit# 17041-10000-41603<<CHANGE OF USE FROM RETAIL TO BEAUTY SALON. EXCEPT FOR THE RESTROOM, LUMINAIRES ARE EXISTING. WALLS ENCLOSED AREA FOR TWO FACIAL ROOMS.PLAN CHECK IS FOR TITLE 24>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38464	13041-20000-26803	633 W 5TH ST 15TH Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	09/26/2013 12:00:00 AM	ADDRESS	34.05099	-118.25468	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON THE 15TH FLOOR. TOTAL SQRFT OF SCOPE OF WORK IS 2623.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38465	13041-10000-07375	1545 W PICO BLVD	90015	1	127-5A203  85	5137032036	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	34.04451	-118.27628	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS (1680 SQUARE FEET) FOR TENANT IMPROVEMENT OF PLS FINANCIAL SERVICES. TWO NEW PANELS WITH TOTAL LOAD < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38466	11041-10000-16207	20519 W ROSCOE BLVD	91306	3	192B109   744	2780028019	C4-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.22022	-118.58047	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.Replacing the existing light fixtures with LED fxtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38467	16041-20001-30539	11762 N MONTE LEON WAY	91326	12	216B121   396	2872010022	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.28721	-118.54603	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.73 KW. MICROINVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38468	15041-20001-38392	10357 N HAINES CANYON AVE	91042	7	204B201   261	2569023040	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.25732	-118.2785	Expedited per customer request.PV1. Install roof mounted PV system sized 20 kW. Interconnected with main service panel.(68) SOLARWORLD SW285 Modules(68) OP 300-MV Power Optimizers(2) SOLAR EDGE SE10000 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38469	11041-20000-14411	8937 N SAN FERNANDO ROAD	91352	6	195B169   259	2631017051	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	01/09/2012 12:00:00 AM	ADDRESS	34.23104	-118.3853	TI FOR A COMMERCIAL BLDG. EPC IS FOR POWER & ENERGY. (Core & shell were submitted under separate application #11041-20001-05168)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38470	11041-10000-25932	630 W HARRY BRIDGES BLVD Bridge	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Closed	01/19/2016 12:00:00 AM	ADDRESS	33.77068	-118.26868	Active Level V Methane detection system for a new pedestrian bridge connecting two buildings with elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38471	19041-20001-10406	5440 N GENESTA AVE	91316	5	174B133   736	2258027010	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.17029	-118.50367	expeditepv1install roof mounted pv system sized 7.6KW AC with battery 5KW interconnetced with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38472	16041-20000-43878	16536 W GILMORE ST	91406	6	180B137   679	2231010060	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.18737	-118.49376	PV1.  Install 8.265 kW DC roof mounted grid tied PV system.  (29) modules with (1) 7.6 kW AC rated inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38473	15041-20001-01764	6220 N TOPANGA CANYON BLVD SUITE 1480	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	08-18-2015 Change to approved set of plans. Changes includes change manufacturer&model # of lighting fixtures and delta 8 &11 only. [[[[[Plan check for power and energy. First time tenant, new restaurant  Luicilles BBQ suite 1480. Total Sqft. 9,970.]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38474	19041-20000-38192	4028 N STONE CANYON AVE	91403	4	163-5A147  54	2277023012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Issued	09/23/2019 12:00:00 AM	ADDRESS	34.14385	-118.46067	PV1.  Install 10.22 kW DC roof mounted grid tied PV system.  (28) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38475	15041-10000-14863	1601 E MARTIN LUTHER KING, JR BLVD	90011	9	115-5A213 170	5117009030	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Expired	06/15/2017 12:00:00 AM	ADDRESS	34.01059	-118.24645	PV1.  Install utility-interactive, roof-mounted PV system.  3.8 kWac with (1) inverter and (12) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38476	15041-10000-16973	11351 W VENICE BLVD	90066	11	114B157   353	4234003060	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Apartment			06/03/2015 12:00:00 AM			PC Info Complete	01/12/2016 12:00:00 AM	ADDRESS	34.01093	-118.42141	Full plan check for a new  4-story 6-unit apartment with one level of subterranean parking.  Fire alarm variance filed 01-12-16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38477	18041-20000-11565	3620 S 5TH AVE	90018	10	120B189  1349	5044030022	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.02219	-118.32226	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consists of (21) modules, (21) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38478	15041-10001-37361	6600 W SUNSET BLVD	90028	13	147A185    65	5547024032	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.09782	-118.33334	Changes to approved set noted under Delta-2: changes in light fixtures and readjustment of lighting load calculation on the panel schedule. This is Plan Check only, permit shall be under the Master E#.Note: Original Electrical Engineer under the master plan  is being replaced by another electrical engineer within the same engineering company.<<PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT. 2-STORY BUILDING. TOTAL AREA 6150 SQ FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38479	12041-10000-23288	5236 N OTIS AVE	91356	3	171B125   259	2161021053	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2012 12:00:00 AM			Verifications in Progress	10/22/2012 12:00:00 AM	ADDRESS	34.16675	-118.53542	New 11.8 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38480	19041-10000-39277	11714 W ARCHWOOD ST	91606	2	180B169   348	2322018019	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1232.03	Electrical	Electrical	Apartment			09/30/2019 12:00:00 AM	07/21/2021 12:00:00 AM		Issued	07/21/2021 12:00:00 AM	ADDRESS	34.19201	-118.38841	FULL PLAN CHECK FOR NEW 5-STORY 37-UNIT APARTMENT BUILDING 1 LEVEL TYPE 1 PARKING GARAGE WITH 4 LEVELS OF TYPE IIIA CONSTRUCTION.  SERVICE SIZE IS 1200A, 120/208V, 3PH, 4WIRE. AREA OF SCOPE 24,518SFBUILDING PERMIT# : 19010-10000-00498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38481	16041-30000-23849	744 N TOYOPA DR	90272	11	126B129   439	4411007020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.04203	-118.52051	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (367) PV roofing shingles (1,635 sq. ft.), and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38482	17041-20000-42366	13057 N GLADSTONE AVE	91342	7	222B157   135	2512002030	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.3074	-118.4246	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.32 KW.$33.63 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38483	18041-10000-03400	850 W WASHINGTON BLVD	90015	1	124-5A203  64	5124020022	[Q]C2-2-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.03641	-118.27704	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38484	17041-20000-30125	15926 W HAMLIN ST	91406	6	180B141   834	2233014016	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Issued	08/28/2017 12:00:00 AM	ADDRESS	34.1876	-118.48031	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 5 kWac and consists of (1) inverter, (16) modules, (1) Tesla Powerwall, and (2) load centers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38485	11041-20001-06987	8722 W 3RD ST	90048	5	138B169   569	4334011056	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Approved	01/12/2012 12:00:00 AM	ADDRESS	34.07344	-118.38225	Changes from previously approved plans.  Changes include LED luminaires and emergency light.  Plan check for energy only. Note: Permit is under 11041-20000-06987.****ENERGY PLAN CHECK RESTAURANT*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38486	19041-20002-09615	4347 N CORONET DR	91316	5	165B129   145	2184030004	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.15063	-118.51909	12/4/19CHANGES TO APPROVED SET CHANGES TO  INVERTER TO 10.0KW. PV SYSTEM SIZE 10.89KW. ALL CHANGES HAS BEEN CLOUDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38487	17041-20000-15334	1498 W SUNSET BLVD #2	90026	1	139-5A209 287	5405001034	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			Not Ready to Issue	07/19/2018 12:00:00 AM	ADDRESS	34.0756	-118.25514	THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER 18041-10000-07957ti to an existing commercial space.  adding new lighting new controls to existing panel.  plan check for energy only.  total square footage 866	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38488	17041-10001-12815	380-384 WORLD WAY MSC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM			Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to an approved set of plans, Note changes on delta 1. Changes include revision of lighting, panels and receptacles. See narrative. (((((PC for power and energy for expansion of LAX terminal with four medium voltage services. Total affected area is 647538 sqft. Building #16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38489	13041-20001-31611	14207 W GAULT ST PV1	91405	6	183B153   291	2217022078	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	ADDRESS	34.19946	-118.44247	EXPEDITE FEES ONLY     <<New 10.46kw rooftop photovoltaic system for an existing single family dwelling.  System is UNGROUNDED>>>.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38490	13041-10000-06202	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy and power for a Starbucks in Tom Bradley Int'l Terminal.  First time tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38491	11041-10000-06111	2029 S CENTURY PARK EAST 31ST FLOOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. TO AN EXISTING HIGH-RISE OFFICE BUILDING, T-24 OVER THE COUNTER PLAN CHECK.  31ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38492	19041-10000-33323	11821 W TEXAS AVE 1-8	90025	11	129B145  1034	4263007028	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Apartment			08/23/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.04581	-118.46178	FULL PC FOR POWER AND ENERGY FOR A NEW APARTMENT BUILDING. SCOPE INCLUDES A NEW 800A 120/240V 3 PHASE 4 WIRE SERVICE DISTRIBUTION BOARD. TOTAL AFFECTED AREA IS 9980 SQ. FT. B#18010-10000-06303	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38493	14041-10000-06656	3608 W EDENHURST AVE	90039	13	154-5A207 196	5435026023	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.11811	-118.26136	TI FOR A  RETAIL. EPC IS FOR T24 & emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38494	12041-10001-03664	175 S FAIRFAX AVE #A	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	DELTA 4 CHANGE TO PERMITTED SET OF PLANS; REVISED SHEET E-1.2 TO SHOW THAT GEN LIGHTS WILL BE SUPPLIED THROUGH CURRENT LIMITING PANEL AND TO RELABEL LAMP HOLDERS FOR MAX WATTAGE- AS-BIUILT SET OF PLANSPLAN CHECK 24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT ON EXISTING RETAIL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38495	12041-10000-06616	12126 W VICTORY BLVD	91606	2	180B165   760	2334001063	C2-1L, P-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.1865	-118.39765	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT EXISTING RETAIL STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38496	17041-10000-37336	3751 S MOORE ST	90066	11	111B153   468	4245016010	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.00173	-118.44173	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 6KVA CONSISTING OF CENTRAL INVERTER (SOLAREDGE SE6000A) AND 22 MODULES WITH (P400) OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38497	12041-20000-04439	18109 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	04/16/2012 12:00:00 AM	ADDRESS	34.26473	-118.52624	T.I. to a space (Salon) of an existing building.  In stall general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38498	18041-10000-15728	8622 S FIGUEROA ST	90003	8	097-5A201 303	6038001027	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	33.95943	-118.28251	PC FOR ENERGY AND POWER  FOR A NEW EXPRESS CAR WASH. SCOPE INCLUDE NEW SERVICE, PANELS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 1474 SQ.FTB#17010-70000-03168PLAN CHECKER TO VERIFY CHARGES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38499	19041-20000-42031	17312 W SUPERIOR ST	91325	12	201B133   435	2755008005	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.24655	-118.51197	Plan check for Energy Storage system, installed 3 Power Wall 2.0 in to existing PV system, Energy Storge System size: 40.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38500	11041-20000-15163	1411 W 190TH ST	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	ADDRESS	33.85852	-118.30317	Ti in an existing office space. Epc is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38501	19041-10000-38468	411 E 5TH ST	90013	14	127-5A213 128	5148011003	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Apartment			09/24/2019 12:00:00 AM			Reviewed by Supervisor	11/13/2019 12:00:00 AM	ADDRESS	34.04454	-118.24446	PC FOR FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. (1) FACP AND (363) DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38502	16041-30000-28161	5328 W SANCHEZ DR	90008	10	117B177   353	5029027014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.01568	-118.36182	VoidPlan check for PV roof mounted system. System size: 3.5kW with 11 AC modules. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38503	13041-10001-00996	936 E PICO BLVD A,B,1/2	90021	14	123A211   255	5132018013	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.03058	-118.24946	DELTA 2 REVISION TO APPROVED PLANS. CHANGES CONSIST OF ADDING ADDITIONAL BRANCH CIRCUITS, REVISION TO T24 ENERGY, RELOCATE ELECTRICAL ROOM, AND CHANGE TO OVERHEAD SERVICE FROM UTLILTY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38504	16041-10000-37230	16000 W VENTURA BLVD SUITE 1201	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.15584	-118.48164	PC FOR TITLE 24. ENERGY ONLY.SOCPE INCLUDES LIGHTING ONLY.TOTAL AFFECTED AREA 1537 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38505	14041-10000-25056	1133 S HOPE ST	90015	14	127-5A207 285	5138014006	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	02/29/2024 12:00:00 AM	ADDRESS	34.0416	-118.26394	PLANCHECK FOR POWER AND ENERGY. NEW HIGHRISE MIXED USE BUILDING.building permit #13010-10000-02854  New 28 story residential tower, 22 levels of residential, 1 level of amenity space, and 5 level of parking above grade and 2 level below grade with ground level commercial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38506	19041-20000-19321	7525 N TOPANGA CANYON BLVD	91303	3	186B101   309	2023002001	[Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.20725	-118.60619	installation of (4) tesla powerwalls ESS rated 5KW each.  Plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38507	16041-20000-13373	7080 W HOLLYWOOD BLVD SUITE 100	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.10134	-118.34445	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR IGNITED SPACES. BUILDING CONNECTED TO HIGHRISE. (VARIANCE HAS BEEN SUBMITTED FOR RECERTIFICATION OF SWITCHBOARD)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38508	09041-10002-13631	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM			Permit Finaled	02/25/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	Change of UPS from 15 to 20 kva. approval does not iclude tapping to 2000 amps bus. To be field evaluated by mr. Tim Moore.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38509	16041-20000-31357	1443 N DEVLIN DR	90069	4	147B169   938	5560001028	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.09572	-118.38735	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (46) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38510	18041-10000-36678	1660 W ANAHEIM ST	90710	15	033B193   373	7411008034	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	04/07/2021 12:00:00 AM	ADDRESS	33.78627	-118.30659	Power plan check for a refinery location, Scope inlcudes a new pump (G-31) located in the hazardous area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38511	10041-10000-17956	20251 W VENTURA BLVD Unit 251-A	91367	3	174B113   515	2166033040	(Q)C4-1LD, (Q)P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			09/10/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	12/01/2010 12:00:00 AM	PIN	34.16986681	-118.57545146	Lighting plan check and electrical for new medical office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38512	19041-10000-11228	4800 E VALLEY BLVD	90032	14	136-5A233 319	5223001024	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.06637	-118.17917	Full pc for a new storage center. Area of scope is 189,000 sqft, service size is 1000A 480/277 V, three phase,4 wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38513	18041-10004-41733	1901 S CREST DR	90034	5	126B169    95	4302007001	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.045	-118.38825	SUPPLEMENTAL CHANGES TO APPROVED SET REMOVING (1) INVERTER, (1) POWER WALL ENERGY STORAGE AND DECREASING NUMBER OF MODULES TO 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38514	13041-10000-32229	2030 N CUMMINGS DR	90027	4	151-5A195 179	5589009019	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.10803	-118.30192	PV1, Install 11.76 kW DC roof-mounted solar array for a single family dweling, interconnect with service panel. Transformered inverter: Fronius IG Plus V 10.0. 48 modules TRINA SOLAR TSM-250PA05.18.New application refer to app# 13041-10000-10556 per applicant request has issued.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38515	19041-10000-42520	235 S BROADWAY	90012	14	130-5A211  43	5149009018	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.05179	-118.2476	Plan Check for energy only, scope of work includes new lighting and receptacles to an existing space. Total indoor sq. ft. 8946 and outdoor sq. ft. 100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38516	15041-30010-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	CHANGES TO THE APPROVED SET OF PLAN. PC FOR PLAN CHECK. CHANGES UNDER DELTA 41. ADDITION OF SOME LOADS TO EXSITING PANEL AND REPLACE 4 AIR CONDITIONS, ADDITION OF LIGHTING IN TERMINAL 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38517	15041-20000-32401	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			PC Info Complete	12/11/2015 12:00:00 AM	ADDRESS	34.2215	-118.42999	Plan check for Medical office power and energy. Convert reception area in to office space and 1 patient treatment room.  Total area: 2,491 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38518	17041-10000-24210	9301 N TAMPA AVE #212	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC FOR POWER AND ENERGY FOR DAVE AND BUSTERS TI. NEW POWER FOR ARCADE SYSTEMS, DISTRIBUTION AND LIGHTING. B#17014-10000-03129	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38519	17041-10000-07551	10643 N GLENOAKS BLVD	91331	7	207B165   200	2536015224	[Q]MR1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Issued	03/09/2017 12:00:00 AM	ADDRESS	34.26268	-118.40012	PC FOR ENERGY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL ARAE 25425 SQ FT. /INDOOR/	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38520	13041-10000-15659	1680 W LOMITA BLVD	90710	15	036B193    44	7410018041	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	33.79766	-118.30698	Commercial TI, 700 sq ft fast food restaurant being converted to a Starbucks.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38521	12041-10000-11966	5868 W ABERNATHY DR PV1	90045	11	099B169    87	4105006015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	33.97104	-118.38429	5.9kw rooftop, photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38522	17041-10000-39465	1653 S WOOSTER ST	90035	5	129B169   902	4303003020	R2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.04873	-118.38358	PC FOR ROOF MOUNTED PV ON SLD.SYSTEM SIZE 3.6KWDC /3.0KWACSCOPE INCLUDES 16 MODUELS AND SINGLE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38523	16041-10000-05403	22222 W VICTORY BLVD BLDG E	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUDRY ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38524	17041-10000-40579	20061 W SATICOY ST	91306	3	186B113   176	2106006041	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.20848	-118.57071	PC for T24 only for outdoor lighting. Replacing existing fixtures with LED fixtures. Total of 12600sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38525	16041-20000-34920	8460 N PENFIELD AVE	91306	3	192B113   270	2782010033	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Issued	11/02/2016 12:00:00 AM	ADDRESS	34.2237	-118.56872	permit fee $0.00 by state senate bill no. 1222Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (47) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38526	12041-10000-15085	633 E 61ST ST	90001	9	105B205   520	6007006021	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			Reviewed by Supervisor	08/29/2012 12:00:00 AM	ADDRESS	33.9845	-118.26399	Plan check for new 15.67KW roof mounted photovoltaic system for an existing commercial building with multiple services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38527	19041-10000-49784	2300 W 3RD ST	90057	1	135A203   214	5154035029	C2-1	Central	Westlake	MacArthur Park	YES	2088.02	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM			PC Info Complete	01/13/2020 12:00:00 AM	ADDRESS	34.06402	-118.27494	PC FOR POWER ONLY. SCOPE INCLUDES REPLACING ELECTRICAL EQUIPMENT WITH EXISTING AC CONDENSER UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38528	16041-10002-08977	3020 W WILSHIRE BLVD	90010	10	132B197    30	5077013038	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/08/2017 12:00:00 AM	ADDRESS	34.06165	-118.28725	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE CONFIGURATION OF INTERCONNECTION WITH UTILITY. THIS SYSTEM IS NOW A NET METER PROJECT. SYSTEM INTERCONNECTS ON THE LOAD SIDE OF EXISTING SERVICE METERING. changes clouded delta 2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38529	10041-10000-13476	5429 N LINDLEY AVE	91356	3	171B125    33	2160016002	RA-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Public Safety Only			07/14/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	ADDRESS	34.16864	-118.52745	ON A SCHOOL CAMPUS , NEW FIRE WARNING SYSYTEM  TO INCLUDE  EXISTINTG BUILDINGS AND TO MONITOR FA DEVICES IN  THE ECC BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38530	14041-20000-03839	4942 W MARATHON ST PV1	90029	13	141B193   467	5535029022	R1-1-HPOZ	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			Corrections Issued	02/11/2014 12:00:00 AM	ADDRESS	34.08433	-118.30664	PV1 ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL. SYSTEM IS TRANSFORMERLESS, @ 1.5 kW DC, WITH (6) MODULES TRINA SOLAR #TSM-250, (1) POWER-ONE PVI-3-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38531	16041-20000-36048	9000 N OWENSMOUTH AVE	91304	3	195B105    53	2779018017	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.23382	-118.60151	PLANCHECK FOR POWER. SERVICE UPGRADE TO 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38532	16041-30000-45572	116 N ROBERTSON BLVD Suite F	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.0758	-118.38356	Plan check for Title 24 only. Project site is an existing tenant space within a high-rise commercial building. Project scope is a tenant improvement. Total lighting area = 1,911 sq. ft.Note: Building application has been generated under 16016-40000-06902	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38533	13041-10001-21486	3200 W 48TH ST	90043	8	111B185   357	5013026016	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM			PC Approved	05/12/2014 12:00:00 AM	ADDRESS	33.99988	-118.32886	plan check only. CHANGES TO APPROVED: EMERGENCY LTG LAYOUT CHANGE. plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38534	10041-20002-14353	1680 N VINE ST	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	09/06/2011 12:00:00 AM		Permit Expired	11/20/2015 12:00:00 AM	ADDRESS	34.10133	-118.32648	Delta 3 revision plan check for installing 400A HP1 panel to supply existing subpanel. Revise service load calculations. Permit includes intercepting existing feeders to new HP1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38535	14041-20000-04911	10839 W KLING ST	91602	2	168B173   674	2421022007	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			02/24/2014 12:00:00 AM			Corrections Issued	04/03/2014 12:00:00 AM	ADDRESS	34.15578	-118.36704	4 STORY 8 UNIT APT WITH SUBTERRANIAN GARAGE. PC FOR POWER AND ENERGY. ENERGY FOR GARAGE. FIRE ALARM VARIANCE. PER BUILDING SUBMITTAL. PLAN CHECK IN ACCORDANCE TO 2011 NEC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38536	16041-10000-37505	20710 W COMMUNITY ST	91306	3	192B109   574	2780006034	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	11/19/2016 12:00:00 AM	ADDRESS	34.22205	-118.58459	PV, INSTALL NEW 8.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.5 STRINGS, (28) MODULES: SUNPOWER E-SERRIES SPR -E20-327(2) INVERTERS: SMA SUNNY BOY 5000TL73800TL-US-22(240)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38537	11041-20000-10595	127 S SAN VICENTE BLVD Bulletin-65TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM			PC Approved	06/02/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	PLAN CHECK TO REVISION BULLETIN # 65 TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38538	16041-20000-37703	21318 W HART ST	91303	3	183B105   688	2138016013	MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.19728	-118.59606	remove existing hid fixtures and replace with new led outdoors.  plan check for energy only 4785 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38539	19041-20000-43323	14985 W VALLEY VISTA BLVD	91403	4	165A147   196	2276026009	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.14642	-118.46096	PV1. INSTALL 10.71 KW DC / 9.76 AC PV SYSTEM WITH (34) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38540	14041-10001-26965	900 N BROADWAY	90012	1	135A215   235	5414013900	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	PIN	34.06407564	-118.23656378	pc for changes to approved set of plans. changes include removal of 6 devices and adding 8. net total of 2 new devices. new layout approved by fire. permit to be issued from 2 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38541	17041-10000-41780	1905 S HILLSBORO AVE	90035	5	129B169  1405	4305029008	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.04605	-118.39029	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW TESLA BATTERY(13.5kwh / 5.8KVA) TO AN EXISTING SOLAR SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38542	19041-20001-06857	8500 S PERSHING DR PV-1	90293	11	096B153  1023	4118004015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	33.9561	-118.442	Expedited plan check fee.PV2.  Install 39.60 kW DC / 35.54 kW AC roof mounted grid tied PV system.  (110) modules with 33.3 kW rated string inverter.System 1 of 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38543	17041-20001-36682	832 S PLYMOUTH BLVD	90005	4	132B189   457	5090028009	[Q]R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.0589	-118.32416	12.7.2017 - Plan check for modifications to approved set. Changing main panel OCPD from 150A to 200A. Only change.======Plan check for PV roof mounted system of SFD. Total system size: 12.960 KW with 36 AC Modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38544	18041-10000-08265	10370 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.25886	-118.57962	Alterations for at a Chase bank- replacing outdoor and indoor luminaires with LED type using existing branch circuitsTotal area is 3748sqft.PLAN CHECK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38545	11041-10000-20326	12463 W VICTORY BLVD	91606	2	180B165   703	2333003031	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.18684	-118.40498	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38546	14041-20000-00626	4432 N BROOKFORD AVE	91364	3	165B097   202	2078003018	RS-1	South Valley		Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.15069	-118.62568	PV1 7.0KWAC 3 STRINGS 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38547	16041-20001-44107	12828 W RIVERSIDE DR	91607	4	168B161   460	2357033019	(T)(Q)RAS4-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	34.15745	-118.41266	10/24/19CHANGES TO APPROVED SET DELTA 15 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38548	10041-20000-10468	6827 N RESEDA BLVD	91335	3	183B125   916	2126022800	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	03/18/2011 12:00:00 AM	ADDRESS	34.19476	-118.53623	Plan check general/emergency lighting for AT&T	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38549	13041-20002-35450	14823 W LASSEN ST	91345	7	201B149   182	2647010018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	ADDRESS	34.2501	-118.45506	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. SOLAR EDGE. TOTAL SYSTEM SIZE 5KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38550	15041-10000-24501	7842 N BURNET AVE	91405	6	189B145   484	2209036014	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.21324	-118.46279	FIRE DAMAGE FOR EXISTING COMMERCIAL BUILDING. THIS SCOPE COVERS TRANSFORMER AND SERVICE REPLACEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38551	16041-20000-35511	16633 W VENTURA BLVD Suite 1440	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for energy only. TI for office - suite 1440 in high rise building. New lighting (incl. emergency) and receptacles. 895sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38552	16041-20000-00893	4513 S SLAUSON AVE	90230	11	111B161   977	4218001019	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			01/11/2016 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	33.99734	-118.41311	Plan check for power and energy. New 4-story, 23 unit apartment building with 1000A 120V/208Y service. 11,437sqft. Fire Alarm Variance on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38553	17041-20000-36056	8900 N DE SOTO AVE	91304	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.23162	-118.58832	Addition of new 225amp panel and 25kva transformer for welding equipment  to an existing distribution board.plan check requested by applicant.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38554	17041-10000-23752	380 WORLD WAY UTiLiDOR	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	12/07/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	instalation of new EFSO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38555	14041-10001-24052	930 S HILGARD AVE 1st floor	90024	5	135B153   541	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM			PC Approved	11/14/2014 12:00:00 AM	ADDRESS	34.06306	-118.44116	Change to approved set by changing light fixture, control, adding and removed lighting from original plan. all chnges apply to delta 4 only.((((plan check for energy only per 2013 Energy standards. high rise. emergency lights installed. Total connected load less than 400A. Verify occupant load and if place of assembly. BLDG#:14016 - 10-17654 9/3/2014: INTERIOR REFURBISHMENT OF 1ST LEVEL LOBBY, LOBBY BAR, PRIVATE LOUNGE, ELEVATOR LOBBY, PASSENGER ELEVATORS, CONNECT LOUNGE, AND RECEPTION (TOTAL 5,556 SQ FT) ))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38556	16041-20000-11855	914 S OLIVE ST	90015	14	127-5A209 166	5139004017	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Issued	05/04/2016 12:00:00 AM	ADDRESS	34.04319	-118.25843	Plan check for energy only. TI to tenant spaces. New general lighting. 3,720sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38557	19041-20000-02208	7350 N RESEDA BLVD	91335	3	186B125   721	2119019019	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Info Complete	01/18/2019 12:00:00 AM	ADDRESS	34.20437	-118.53583	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600 Amps and new subpanels. No load is included in this scope of work.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38558	16041-20000-16823	1259 S WESTWOOD BLVD	90024	5	132B153   573	4324004016	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.05748	-118.4433	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO OFFICE. H&R BLOCK. 1121 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38559	14041-20000-31346	6816 N INDEPENDENCE AVE 1-18	91303	3	183B109   872	2138029004	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1349.03	Electrical	Electrical	Apartment			11/12/2014 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.19428	-118.59046	PLANCHECK FOR POWER AND ENERGY. NEW 18-UNIT APARTMENT. 3 FLOORS. [ VERIFY IF FIRE ALARM IS REQUIRED; NO VARIANCE HAS BEEN SUBMITTED]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38560	14041-20000-20691	20008 W VINTAGE ST	91311	12	204B113   715	2726003035	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.25165	-118.56961	Standard Plan for 8.925KW PV1 roof-mounted system including: (35) Trina Solar TSM-255 modules, and (2) Power One PVI-3.6-TL transformerless inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38561	17041-10000-04307	330 S FERRY ST	90731	15	018B205    81	7440027***	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	33.74727	-118.26189	PC AND PERMIT TO REPLACE EXISTING LIGHTING FOR MORE EFFICIENT TYPE. PC FOR T24 ENERGY ONLY. TOTAL AREA: 76,150 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38562	12041-10000-20190	8929 N OSO AVE	91311	12	195B113    50	2781001017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.23333	-118.57549	Plan check for new installation of sprinkler monitoring system. Permit for sprinkler monitoring system and branch circuit to supply monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38563	17041-10000-36222	1640 S SEPULVEDA BLVD suite #100	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Info Complete	10/10/2017 12:00:00 AM	ADDRESS	34.04838	-118.44468	T-24, PC FOR ENERGY ONLY.  TENANT IMPROVEMENT FOR EXISTING COMMERCIAL OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5751 SQ. FT. . B#17016-10000-29558	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38564	10041-10000-25857	740 S TERMINAL ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			Reviewed by Supervisor	03/15/2011 12:00:00 AM	ADDRESS	34.03512	-118.23983	NEW 6 STORY MIXED USE BUILDING. RETAIL ON THE 1ST FLOOR AND 5 STORIES OF PARKING ABOVE. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38565	17041-10000-43474	1900 S AVENUE OF THE STARS #300	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for Title 24 only in existing T.I. office high rise. Total area: 2,663 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38566	13041-20000-07366	13350 W SHERMAN WAY	91605	2	183B157    86	2328025026	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			Reviewed by Supervisor	04/05/2013 12:00:00 AM	ADDRESS	34.20101	-118.42426	New 800 ampere service for existing shell building.  Site lighting is installed, plan check for T-24 lighting and for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38567	11041-10000-14092	22142 W SHERMAN WAY	91303	3	183B101   109	2024012003	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.20073	-118.60949	NEW FIRE ALARM SYSTEM FOR A 2-STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38568	18041-20000-44923	758 S ALVARADO ST	90057	1	132A203   235	5141019008	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.05497	-118.27758	Change of use from dance hall to restaurant.  Plan check for Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38569	19041-10000-01292	11046 W MAGNOLIA BLVD	91601	2	171B173   609	2353006014	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.16478	-118.3721	PLAN CHECK FOR TITLE 24 ONLY CHANGE OF USE FROM EXISTING AUTOBODY REPAIR TO NEW BAR LOUNGE. TOTAL SQFT 1260.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38570	19041-20000-01504	12830 W RAYMER ST	91605	2	186B161   542	2324005024	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.20426	-118.4128	Plan check for Title 24 only in existing space remodel interior Tenant Improvement. Total area: 5884 sq ft. B#18016-20000-39604	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38571	15041-20000-13952	5398 E NAVARRO ST	90032	14	144A237   261	5219023012	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Expired	06/02/2017 12:00:00 AM	ADDRESS	34.08808	-118.16363	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.Service size: 7.6kW (3.8+3.8). Ungrounded system. (22) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38572	11041-20000-19174	7858 N VAN NUYS BLVD	91402	6	189B149   643	2212028035	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.21376	-118.44851	7-Eleven t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38573	19041-30000-12923	2049 S CENTURY PARK EAST 1st Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement to a portion of the 1st floor. Total lighting area = 525 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38574	11041-20000-15185	515 S FIGUEROA ST 3rd Floor-Restrooms	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check T24 Energy and emergency for 3rd floor restrooms. Permit for work on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38575	15041-20000-10345	10344 N OSO AVE	91311	12	204B113    53	2707016014	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.25927	-118.57518	Plan check for a PV1 roof-mounted PV system. System size is 8 kWac and consists of (2) inverters, (38) modules, and (1) 125-amp load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38576	16041-10000-41743	8641 N SEPULVEDA BLVD	91343	6	195B145   573	2654020056	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.22748	-118.46794	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 38775 SQ FT. (OUTDOOR LIGHTING)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38577	15041-10000-39875	6800 N OWENSMOUTH AVE #160	91303	3	183B105   949	2138006044	P-1VL-RIO, [Q]CR-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.19413	-118.60138	TI O OFFICES. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38578	13041-20000-15243	6922 W HOLLYWOOD BLVD	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.10137	-118.34103	T24 FOR EXISTING COFFEE BEAN. REPLACING INCAND. FIXTURES TO LED FIXTURES. SCOPE OF WORK: 543 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38579	17041-10001-12555	10250 W SANTA MONICA BLVD STE. 1470	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Revision to approved set noted as Delta 3 and 4 for ""APPLE STORE"" Ste. 1470 at Westfield Century City.  Scope includes remove, add, and relocate circuits for lighting and power, and revise floor plan accordingly;  Revise lighting fixtures and T24 worksheets accordingly. This is plan check only, permit is covered under master plan."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38580	19041-20000-33071	505 S FLOWER ST	90071	14	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Info Complete	12/27/2019 12:00:00 AM	ADDRESS	34.0515	-118.25654	ADD NEW LOADS AND EQUIPMENTS ON EXISTING PANELS AND SERVICE. PLAN CHECK FOR POWER AND ENERGY. TOTAL AFFECTED AREA 1448 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38581	15041-10001-07133	10323 W LORENZO DR	90064	5	126B161   195	4308011034	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			Reviewed by Supervisor	03/18/2015 12:00:00 AM	ADDRESS	34.04039	-118.40725	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38582	13041-20001-33073	9838 N CHICOPEE AVE	91325	12	201B129   115	2755013018	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.24986	-118.51353	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 12KWAC. 51 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38583	18041-20000-35073	4618 N WESTCHESTER DR	91364	3	168A111   100	2174012023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.1538	-118.58242	PV1.  Install 8.954 kW AC roof mounted grid tied PV system.  (34) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38584	12041-10000-26398	8041 N WHITSETT AVE	91605	6	189B161   174	2308010901	OS-1XL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	11/02/2012 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	34.21758	-118.40542	"NEW 600 AMP SERVICE IN A PARK TO RE-FEED TWO EXISTING BUILDING AND A NEW ""STATE APPROVED"" PRE-FAB 400 AMP BUILDING. CORE AND SHELL ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38585	14041-10002-21963	200 WORLD WAY Terminal 2	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Approved	02/09/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	2/9/2015 Changes to an approved set of plans. All changes under this plan check have been clouded and labelled as Delta 1. Changes include changes to energy calculations (installed lighting has been reduced) and changes to the connected load (load has been increased). (((Revisions to approved set.  New sheet E106 for additional dry storage room (existing lighting to be reused per applicant).  Revisions to panel schedules on sheet E602.)))(((Plan check for power and lighting.  Total area = 3,921 sq. ft.T.I. to LAX terminal 2.  Installation of emergency lighting, recepticles, fire alarm system (11 notification devices), and panelboards (total connected load = 450 A))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38586	14041-10000-20416	1400 N DEVLIN DR	90069	4	147B169   864	5560037007	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.09595	-118.38641	""" $0 permit fee is due to the 2012 Senate Bill No. 1222"" PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY SINGLE FAMILY HOUSE, INTSERCONNECT WITH MAIN SERVICE PANEL.(53) SUNIVA OPT265-60-4-1BO(2) SOLAREDGE INVERTERS: SE6000A-US-ZB-U & SE5000A-US-ZB-U"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38587	12041-10000-14644	6633 N FALLBROOK AVE 801B	91307	3	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Closed	10/24/2012 12:00:00 AM	ADDRESS	34.19044	-118.62372	Plan check for power and energy. 4486 sqft. Single story commercial. 129 occupants.TI FOR (E) RETAIL SPACE (TOTAL AREA IS 4486 SQFT): NON-BEARING PARTITIONS, SUSPENDED CEILINGS, FINISHES, FIXTURES, AND RELATED MILLWORKS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38588	19041-10000-48207	4543 N ETHEL AVE	91604	4	168B161  1048	2360028035	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/11/2020 12:00:00 AM	ADDRESS	34.15348	-118.4183	(ePlan) NEW ROOF-TOP SOLAR INSTALLATION 12.95KWdc (11.66KWac) USING 37 SUNPOWERSPR-X21-350-BLK-E-AC MODULES. CONNECTED TO A 200 AMP EXISTING SERVICE.Fees $33.63 due to California Senate Bill 1222 and AB 1414MAIN CB DERATING ON SEPARATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38589	09041-10010-08059	6250 W HOLLYWOOD BLVD	90028		148-5A189 132	5546029917	C4-2D-SN		Hollywood	Central Hollywood			Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM			PC Approved	01/27/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	Supplemental is for the change to previously approved.  Change is to feeder size to 2 sets of 250 kcm, 500A C/B feeding XFMR T11HS2.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38590	16041-20000-35590	6610 W LEXINGTON AVE	90038	4	144B185   463	5532023001	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.09249	-118.33366	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,085 sq. ft.Note: Building application has been generated under 16016-20000-24102	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38591	13041-20000-08386	1805 N MELHILL WAY	90049	11	135B133    54	4432011045	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.06745	-118.50136	INSTALL A  NEW 600 AMP SERIVCE TO SUPPLY NEW AND EXISTING PANELS.  Panels are located at the pool wall, house, house basement, and barn.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38592	11041-10000-00857	2408 W JAMES M WOOD BLVD Bldg C	90006	1	132A201   289	5136002032	C2-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM			Corrections Issued	01/14/2011 12:00:00 AM	PIN	34.0547304	-118.28241558	CHANGE OF USE FROM PRINTING SHOP TO DAY CARE  (3778 SQ FT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38593	14041-10004-15812	600 W WORLD WAY NORT	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	PIN	33.94461393	-118.39808495	ADDITIONAL SCOPE OF WORK. PERMIT TO INCLUDE RENOVATION OF 2 RESTROOMS. PC FOR ADDITIONAL WORK DONE. REFERENCE TITLE 24 HAS BEEN INCLUDED. INSPECTOR VERIFY COPY OF ORIGINAL APPROVED SET. PERMIT TO BE ISSUED FOR ADDITIONAL WORK INVOLVED.ADDRESS HAS BEEN UPDATED TO MATCH PERMITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38594	17041-20000-32135	1044 S TIVERTON AVE	90024	5	132B153   151	4360002006	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Issued	09/13/2017 12:00:00 AM	ADDRESS	34.06077	-118.443	Plan check for energy only. TI to existing hotel building. New lighting (incl. emergency) - 3,490sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38595	13041-20000-32815	1465 N ARMADALE AVE	90042	14	157-5A223  82	5474016033	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.12422	-118.2117	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.5KW. 1 COMBINER 1 INVERTER AND 22 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38596	13041-10001-27887	19626 W ANADALE DR	91356	3	162B117   200	2180013004	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.14096	-118.56138	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 5.25kW. TRANSFORMERLESS, UNGROUNDED.2 STORY. NON STANDARD PLAN.(21) TRINA SOLAR # TSM-250PA05.18(1) POWER ONE # AURORA PVI 3.6-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38597	17041-20001-00382	15760 W STRATHERN ST	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Issued	04/04/2017 12:00:00 AM	ADDRESS	34.21559	-118.47701	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of an optional standby generator system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38598	14041-10000-22197	5088 E VALLEY BLVD	90032	14	138A235   346	5221002025	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.07096	-118.17314	Pc for t24 only. TENANT IMPROVEMENT OF EXISTING RETAIL. 5 LIGHTS, 17 OUTLETS AND SWITCHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38599	16041-10000-31432	1221 N STONE CANYON ROAD	90077	5	147B149   546	4370007029	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM			PC Info Complete	11/03/2016 12:00:00 AM	ADDRESS	34.09592	-118.44986	PC FOR POWER. Two story addition to existing two story single family dwelling with attached garage, including major remodel. SERVICE UPGRADE TO 800A. B# 15014-30000-00897Note: Permit fees are paid under PCIS#15014-30000-00897	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38600	14041-20000-27465	8301 W BEVERLY BLVD	90048	5	138B173   395	5514009027	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.07623	-118.37013	Plan check for energy only. Change use of a portion of the health spa to restaurant. New lighting, incl. emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38601	19041-10000-07847	20929 W VENTURA BLVD UNIT 40	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTING AND EXIT SIGN TO EMPTY TENANT SPACE FOR FUTURE TENANTPLAN CHECK IS FOR TITLR 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38602	14041-10001-06470	16821 W LIVORNO DR	90272	11	126B121   137	4415014008	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.04433	-118.54534	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 8.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH  MAIN SERVICE PANEL.(34) MODULES: CANADIAN SOLAR CS6P-250PX(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38603	16041-20000-42084	411 S BRISTOL AVE	90049	11	129B137   323	4406029016	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	BUILDING	34.05085533	-118.48649956	Plan check for power only. Two-story addition and remodel to single-family dwelling w/attached garage => had to change service from 400A to 600A, per inspector request: plan check service, distribution equipment, and feeders (incl. for fault current) per engineered drawings. Combined building permit application #14014-10000-02787.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38604	18041-20000-47305	7018 1/2 N DARBY AVE	91335	3	183B125   527	2125004010	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	02/22/2024 12:00:00 AM	ADDRESS	34.19809	-118.53336	New commercial core and shell warehouse building.  New 800A service and subpanels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38605	17041-10000-17585	350 S GRAND AVE 25th flr-c-orridor	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.05173	-118.2522	PC FOR ENERGY. REPLACING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, AND NEW 0-10V CONTROLS. TOTAL AEA OF LIGHTING 1035 SQ FT.( 25th floor corridor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38606	18041-20000-45098	1520 N AMALFI DR	90272	11	132B133   153	4425021020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.0581	-118.50418	Plan check for PV roof mounted system, system size: 20.88kW DC, 18.619kW AC with 58 AC Modules connected to 400A panel, 400A Service.$24.91 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38607	19041-20000-17993	17535 W ROSCOE BLVD	91325	12	192B129   287	2787016004	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.22118	-118.51625	Plan check for PV roof mounted system, system size: 15.84KW DCwith 48 PV Modules and 48 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38608	18041-10000-10189	4823 N RIVERTON AVE	91601	2	168B177   446	2421013032	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.1583	-118.36612	PC for ner LG battery,  multimode inverter, 100A backup panel. Backup panel installed with interlock switch for battery and utility feed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38609	17041-20000-13254	15157 W ROSCOE BLVD	91402	6	192B145   371	2654024013	(Q)RAS4-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.22161	-118.46296	Plan check for installation of solar pv system, roof-mounted array on commercial building.Interconnect with a 400A subpanel. 23.4kW ungrounded system [9+14.4]. (82) 300W pv modules.Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38610	16041-10002-38672	7858 W DENIVELLE ROAD	91040	7	210B193   241	2552013012	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2017 12:00:00 AM			PC Approved	01/06/2017 12:00:00 AM	ADDRESS	34.27226	-118.30459	01/06/2017 Changes to an approved set of plans. Changes include relocation of the sub-panel and inverter and module layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38611	10041-20000-06226	12700 W VENTURA BLVD 1ST , 2ND	91604	2	162B161    29	2384022039	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.14449	-118.40998	ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38612	19041-10000-17673	8500 W BEVERLY BLVD Unit #715	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) 1902 SQ FT RETAIL SPACE IN COVERED MALL IN SUITE #715.INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BUILDING PERMIT: 19016-10000-12094	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38613	18041-10000-03015	5850 S VERMONT AVE	90044	9	105B197    72	6004001024	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			PC Approved	04/09/2018 12:00:00 AM	ADDRESS	33.98773	-118.29129	PC for power and energy for first time tenant for guard room. Installing new panel, lights, receptacles and equipment. Total area is 750sqft. B# 16014-10003-05439	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38614	13041-20000-33868	8445 N OAKDALE AVE	91306	3	192B113   295	2782010004	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Issued	12/26/2013 12:00:00 AM	ADDRESS	34.22341	-118.56682	PV1 TRANSFOMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. 24 MODULES AND 2 INVERTERS. SUBMITTED PER APPLICANT REQUEST	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38615	11041-10004-01491	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM			PC Approved	03/21/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Plans are revised to show changes in the routing of the conduits containing the FA conductors. Some conduits were routed underground in error to permitted plans. Also, heat detectors at the gate bridge/building junction are to e monitored in order to provide compatbility with the FA system.Sheet FA0021 will have letter and drawing showing the encasement of the conduits undergroundNew fire alarm system for the Tom Bradley terminal. EPC is for power. (South concourse) ((((( addition of vesda systems to previously approved set 10-19-11 )))))))))))))))))))))))))Delta 6,, changes made to previously approved set.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38616	19041-20000-36709	3041-3045 N GILROY ST	90039	13	151-5A211 253	5437029029	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Issued	10/02/2019 12:00:00 AM	ADDRESS	34.10782	-118.25047	Core and shell electrical upgrade.  600A 240/120V 3ph-4w delta service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38617	14041-20000-14930	9301 N TAMPA AVE kiosk 5546	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for energy only. New kiosk in Northridge mall. Installation of new lighting in kiosk and in a separate existing storage room. Permit under separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38618	16041-10000-30994	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Closed	02/11/2019 12:00:00 AM	ADDRESS	33.94955	-118.38342	Plan check Title 24 only new storage, one story building West Storage-Temporary Maintenance Shop. Total area: 2,640 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38619	19041-20001-37037	16700 W SCHOENBORN ST	91343	12	192B137   254	2689011009	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.22247	-118.4965	PV3 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING COMMERCIAL LOW RISE BUILDING. SYSTEM SIZE IS 52.875 KW DC/39.67KW AC. SCOPE OF WORK CONSISTS OF (141) PV MODULES WITH OPTIMIZERS, (2) 14.4 KW INVETERS, A 11.4 KW INVERTER, 112.5 KVA TRANSFORMER, A 125A SUB PANEL,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38620	11041-10000-00148	6017 N LAUREL CANYON BLVD	91606	2	177B165   671	2333013063	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM			Reviewed by Supervisor	01/31/2011 12:00:00 AM	ADDRESS	34.17993	-118.39671	11.8KS PHOTOVOLTAIC SYSTEM ON THE ROOF OF A PRIVATE SCHOOL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38621	13041-10001-19769	4550 W PICO BLVD C322	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM			PC Approved	08/21/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	"(((metro: changes to approved set of plans: RETAIL TI. RESUBMIT ""AS BUILT PLANS"" PER INSPECTOR)))((van nuys: changes to approved set of plans. new enginner on record. application taken as new. t24 energy only. )))Retail TI for new clothing store in shopping center.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38622	17041-10000-12442	1726 W PICO BLVD	90015	1	127-5A203  49	5135020022	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.04527	-118.27865	PC FOR ENERGY. INTERIOR T.I. TO EXISTING RETAIL. NO CHANGE OF USE. TOTAL AREA 15785 SQ FT.B # 17016-10000-06865	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38623	13041-10000-03207	6325 N BEEMAN AVE	91606	2	177B161    41	2332012019	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.18554	-118.40749	PV1 FOR SINGLE STORY HOUSE.  MICROINVERTER INSTALLATION.  28 MODULES, 6.0 KW DC SYSTEM.  {MICROINVERTER: ENPHASE M215-60-2LL-S22} {MODULES: SUNMODULE SW240}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38624	16041-20000-23119	5123 N MONTE BONITO DR	90041	14	162A229    79	5691015013	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.13968	-118.19005	Plan check for PV roof mounted system. System size: 3.8kW with 13 modules and 1 inverter(3.8kw). Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38625	15041-20002-23754	17501 W RAYEN ST	91325	12	195B129   200	2768026009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.23232	-118.51605	06/15/2016 Changes to an approved set of plans. System size is now 15.2 kWac and consists of (2) inverters, (71) modules, (2) combiner boxes, and (1) load center.*****Previous Work Description*****Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 16 kWac and consists of (3) inverter, (84) modules, (1) combiner boxes, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38626	17041-20002-27543	11631 W VICTORY BLVD	91606	2	180B169  1019	2335012019	C1-1VL, RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	11/23/2021 12:00:00 AM	ADDRESS	34.18685	-118.38564	07-19-2019 Changes to an approved set of plan, changes include addition of panels and load and load distribution panel, exterior lighting. All changes has been clouded as delta C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38627	14041-20000-05220	5801 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	33.97387	-118.41995	ROOF-MOUNTED,PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38628	13041-20000-10756	840 W DOWNEY WAY	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.01997	-118.28717	Relocate one subpanel, change to lighting, loads, in an existing classroom laboratory.  Occupancy load is less than 99 and load is less than 400 amps per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38629	15041-10000-14733	1353-1355 S ABBOT KINNEY BLVD	90291	11	108B145  1282	4239027013	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	33.99081	-118.46612	T24 ONLY.  RETAIL TI. NO CHANGE OF USE. TOTAL AREA 2108 SQ FT WITH TAILORED METHOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38630	15041-20000-39889	17424 W HEMMINGWAY ST	91325	12	189B129   849	2201026016	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.21339	-118.51266	PV1. Install roof mounted PV system sized 11.4 kW. Interconnected with main service panel.(47) Solarworld Sunmodule SW286W Modules(35) Solar Edge P300 Power Optimizers(1) Solar Edge SE 11400A  Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38631	11041-10000-11428	10250 W CONSTELLATION BLVD 4th, 5th &-6th	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI IN AN EXISTING HI-RISE OFFICE BUILDING ON THE 4TH, 5TH & 6TH FLOORS. PLAN CHECK IS FOR POWER & ENERGY. <<<<<<<<Variance to seperate fire alarm system is required>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38632	18041-10000-32116	3310 N VERDUGO ROAD	90065	1	153A215   332	5456001038	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			Reviewed by Supervisor	08/27/2018 12:00:00 AM	ADDRESS	34.11195	-118.23579	Install New rooftop solar system on a Commercial Building, system size 13.2 kW DC/ 11.56 kW AC. Install (48) modules CSUN275-60P, and (48) Enphase IQ6	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38633	18041-10000-34286	3467 E WHITTIER BLVD	90023	14	121-5A227 147	5188004037	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.027	-118.19883	PLAN CHECK FOR FIRE ALARM SYTEM - SYSTEM CONSIST OF 1 FIRE ALARM PANEL AND 48 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38634	16041-20000-34128	6600 N TOPANGA CANYON BLVD 9003	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM			PC Info Complete	09/26/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	New kiosk in mall.  Plan check for energy only.  Total area 205 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38635	15041-10001-07329	6100 N SEPULVEDA BLVD	91411	6	177B145   597	2242025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	34.18076	-118.46437	Change to approved set by removing (2) diesel tanks on the floor plan, and adding (1) new M.T.S switch; all changes are under delta_6 only.(((PC FOR POWER AND ENERGY. ADD NEW DIESEL TANK AND 4 NEW DISPENSER AND REPLACE 6 ESIXTING DISPENSER LED CANOPY LIGHTS. ADD NEW PANEL. GAS STATION. HAZARDOUS AREA. TOTAL AREA 5138 SQ FT.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38636	14041-10000-11991	4735 N SEPULVEDA BLVD	91403	4	168B145   607	2264001043	C2-1L, R4-2L, [T][Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			05/06/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.15623	-118.46637	T24 ONLY.  REMOVING EXISTING  LIGHT FIXTURES AND REPLACING WITH NEW ONE IN CORIDORE. HI RISE APARTMENT BUILDING, TOTAL AREA 30108 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38637	15041-20001-02851	12468 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.97899	-118.41015	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38638	17041-10000-37907	220 E CANNERY ST	90731	15	015B205     4	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM			PC Approved	10/25/2017 12:00:00 AM	PIN	33.74062542	-118.26665485	Plan check for Title 24 only existing building T.I. storage space outdoor lighting. Total area: 3450 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38639	14041-10000-27214	1522 E COLON ST	90744	15	036B213   350	7426019017	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/30/2014 12:00:00 AM	ADDRESS	33.79175	-118.24464	INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(6) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38640	19041-10000-39729	7723 N FULTON AVE	91605	2	189B157   941	2303006004	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	11/09/2019 12:00:00 AM	ADDRESS	34.21074	-118.42277	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 18.9 PV1 SYSTEM CONSISTING OF 60 MODULES USING MICROINVERTERS(IQ7X-96-2-US) CONNECTED TO A NEW 200A SERVICE.  PANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38641	15041-10000-35505	2402 E ANAHEIM ST	90744	15	030B213   336	7440002032	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC for power to an existing hazardous site (petroleum refinery). Installing a water tratment system. Scope includes 13 equipment connected to a 480 volt power system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38642	16041-20001-43704	9111 N SUNLAND BLVD	91352	6	195B173   632	2408004010	QM1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.23513	-118.36751	PV2.  Install 52.65 kW roof mounted grid tied PV system on (E) commercial warehouse building.  (162) modules with (3) 14.4 kW rated central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38643	13041-10000-33892	777 E 12TH ST STE# 1-13	90021	14	123A211    59	5132010036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.03264	-118.25093	TITLE 24 PART 6 ENERGY LIGHTING WORK FOR 396 SQ FT AREA. REMOVING (E) HID LIGHT FIXTURE AND REPLACING WITH NEW FLOURESCENT FIXTURES.  REPLACING TOTAL (2) UNITS ON EXISTING CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38644	16041-20000-20084	4211 N GAYLE DR	91356	3	165B117   324	2177005024	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.1474	-118.55142	PERMIT FEE $8.64 BY STATE SENATE BILL NO.1222 PV1INSTALL ROOF MOUNTED PV SYSTEM SIZE 13.7KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38645	14041-10000-05316	755 N VIRGIL AVE	90029	13	141B197   295	5539017014	[Q]C1-2D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.08487	-118.28701	CHANGE OF USE FROM BEAUTY SALOON TO JUICE BARPERMIT WAS OBTAINED ON 14041-10000-01647; ADDITIONAL PERMIT IS REQUIRED FOR THE WORK BEING DONEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38646	19041-20000-22570	3099 N MANDEVILLE CANYON ROAD	90049	11	147B133  1967	4491009025	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM			Corrections Issued	03/18/2020 12:00:00 AM	ADDRESS	34.09844	-118.5047	Installation of a 100 kW 240/120V 1ph-3w optional standby generator and ATS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38647	14041-20000-17702	3229 W CASITAS AVE	90039	13	153B209   585	5436002027	MR1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Corrections Issued	07/01/2014 12:00:00 AM	ADDRESS	34.11548	-118.25102	T.I. and change of use from (E)warehouse/manufacturing to sound score production. pc for t24 energy only. new lighting in existing offices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38648	19041-20000-15075	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38649	16041-10000-33184	3040 N TREADWELL ST	90065	13	156B209   388	5458006014	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.12014	-118.24911	PC FOR TITLE 24. ENERGY ONLY. SCOPE OF WORK INCLUDES INSTALLTION OF NEW LED FIXTURE.TOTAL AREA OF 19400 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38650	15041-20000-03149	6344 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	TI FOR PANERA BREAD IN TOPANGA VILLAGE (WESTFIELD).  FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38651	18041-20001-29444	8631 W 3RD ST Ste 615E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.07373	-118.38036	11/29/2018 Changes to an approved set of plans. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 compliance form. Scope of work has expanded and is now a total lighting area of 3,342 sq. ft.*****Previous Work Description*****Plan check for power and energy. Project site is a tenant suite in an existing commercial building. Project scope is a tenant improvement to office space. No patient care areas in this scope of work. Total lighting area = 1,740 sq. ft.Note: Building permit has been issued under 18016-20000-11070	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38652	17041-10000-19236	7407 N VAN NUYS BLVD	91405	6	186B149   533	2218004014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.20521	-118.44899	PC for T24 for outdoor lighting. PC for replacement of 7 HID fixtures with new LED units. Total area of 17450 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38653	18041-10000-16458	18648 W CLARK ST	91356	3	174B121   536	2160006023	C2-1VL, P-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.1715	-118.53992	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38654	16041-10001-02089	17219 W MIDWOOD DR	91344	12	216B133   463	2606014018	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	34.28662	-118.50865	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{PV1, Install 12.455 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (2) INVERTER:  ABB PVI-4.2 & 6000-OUTD-S-US-Z-A.  (47) Modules: KYOCERA  KU2656ZPA}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38655	12041-20000-08945	21850 W OXNARD ST main lobby	91367	3	177B105    80	2146006045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	07/02/2012 12:00:00 AM	ADDRESS	34.17895	-118.60413	T.I. to existing hotel at the main lobby area.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38656	19041-10000-41144	2241 S FEDERAL AVE	90064	11	123B153   349	4260014013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.03429	-118.4452	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTUERES -T/24 ONLY INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38657	15041-10000-27565	5836 S MCCONNELL AVE	90094	11	102B161  1270	4211037026	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/21/2015 12:00:00 AM			Reviewed by Supervisor	09/03/2015 12:00:00 AM	ADDRESS	33.97502	-118.41628	NEW APARTMENT BLDG TYPE A. ONE OF 7 UNITS APARTMENT BUILDING. BLDG NUMBER 6 BLDG APP: 15010-10000-01751	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38658	12041-10000-13231	7614 N HAYVENHURST AVE	91406	6	186B137   381	2205010905	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.20934	-118.49223	PLAN CHECK POWER AND ENERGY.  NEW OFFICE BUILDING, SITE LIGHTING, AND GATE. VAN NUYS AIRPORT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38659	18041-10000-42230	133 S NORMANDIE AVE	90004	10	138B193  1071	5518002007	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Apartment			11/02/2018 12:00:00 AM			PC Approved	11/07/2018 12:00:00 AM	ADDRESS	34.0727	-118.30063	Energy plan check for a 2-story 4-unit apartment building. Scope includes new ligting and equipment with a total area of 5460-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38660	16041-20000-38183	1201 E 7TH ST	90021	14	126A213   652	5147034016	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			10/27/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.03762	-118.24209	PV2.  Installation of 10.0 kW AC roof-mounted grid-tied PV system on 3-story apartment building.  (33) modules with (1) 10kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38661	19041-20000-35972	20247 W SATICOY ST	91306	3	186B113   163	2114004023	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Apartment			09/10/2019 12:00:00 AM	05/04/2022 12:00:00 AM		Issued	05/04/2022 12:00:00 AM	ADDRESS	34.20847	-118.5746	FULL PLAN CHECK FOR NEW 2000A SERVICE. T24 INCLUDED TOTAL SQUARE FOOTAGE = 39249 SFPER BUILDING PERMIT 18010-10000-04012New 4-story, 43-unit, Apartment building with 4 units set aside for  Low Income, with Roof Deck,  over 1evel of subterranean parking garage	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38662	12041-10000-28652	2916 E OLYMPIC BLVD	90023	14	120A221   162	5170025003	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.02206	-118.21517	SINGLE STORY WAREHOUSE. PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGTHS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38663	16041-20000-10768	201 N FIGUEROA ST 8TH FLOOR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM			Corrections Issued	03/30/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	PLANCHECK FOR T24 ENERGY ONLY.  TI FOR OFFICES. 8TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38664	14041-10000-09642	2050 S CENTURY PARK	90025	5	132B161    66	4319004139						2679.01	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM			Corrections Issued	04/11/2014 12:00:00 AM	ADDRESS	34.05529	-118.41777	permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A per applicant. no emergency lighting. BLDG#13010.10.03719: CONSTRUCT ADDITION TO (E) STORAGE/ELECTRICAL/MECHANICAL BUILDING FOR 2-STORY GUARD HOUSE WITH  STORAGE AREA AND ATTACHED COVERED VEHICLE ENTRANCE.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38665	10041-10000-12778	500 W WORLD WAY MCP-08	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/03/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-08. This applicaation separates MCP-08 from the entire project on PCIS 09041-10001-24166( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38666	11041-10000-01628	460 S LA BREA AVE	90036	4	135B181   560	5507009014	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.06521	-118.34382	T.I. Lighting and Power.   Title 24 Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38667	16041-10000-03196	20331 W ITASCA ST	91311	12	201B113   760	2748015027	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.24532	-118.57666	PV1, ROOF MOUNTED SOLAR SYSTEM USING OPTIMIZERS. (19) MODULES AND (1) INVERTER- 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38668	14041-10000-19209	5630 S BROADWAY	90037	9	108B201  1087	5101028028	C2-1VL	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	33.99088	-118.27809	PLANCHECK FOR POWER. UPGRADING THE SERVICE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38669	15041-10001-30764	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM			PC Approved	12/02/2015 12:00:00 AM	ADDRESS	34.18686	-118.37207	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE RELOCATION OF LOAD ONTO NEW PANEL. CHECKING NEW LIGHITNG LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38670	16041-10000-04960	8500 W BEVERLY BLVD Space-778	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a T.I located in the Space.778 of the beverly Hill Center. Scope include new lighting, equipment, and receptacles. Total area is 1946-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38671	13041-20000-34461	6739 N LINDLEY AVE	91335	3	180B125   114	2125025005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.19315	-118.52748	PV1 MICROINVERTER STANARD PLAN. TOTAL SYSTEM SIZE 4.32KWAC. 20 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38672	18041-20000-48448	7521 W MULHOLLAND DR	90046	4	156B177   188	2427005037	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.12575	-118.35915	Plan check for PV roof mounted system, sytem size:19.8kW DC, 17.1kW AC, with 60 microinverters and 60 PV Modules connected to 600A existing Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38673	13041-20000-33209	14006 W RIVERSIDE DR Unit 235	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Issued	12/03/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	UPGRADING PANEL SECTION TO 800A. RELOCATING METERING SECTIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38674	13041-20001-26989	13949 W TYLER ST	91342	7	228B153   119	2503019054	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.32399	-118.43802	EXPEDITE FEES ONLY.<<<New 8.06kw rooftop PV for an existing single family residence.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38675	19041-10000-01282	9400 W READCREST DR	90210	4	147B165   515	4352010032	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM			PC Info Complete	06/10/2019 12:00:00 AM	ADDRESS	34.09592	-118.40477	PLAN CHECK FOR POWER AND ENERGY FOR SFD W. ATT GARAGE. SCOPE OF WORK INCLUDES NEW 400AMPS SERVICE,120/240 1PH, CIRCUITS EQUIPMENTS AND LIGHTIN. BLD# 18014-30001-00206	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38676	13041-10000-04025	23016 W SYLVAN ST	91367	3	177B097   148	2039010019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.18447	-118.62821	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A  SINGLE STORY HOME. SYSTEM SIZE IS 11.04 KW (46 MODULES) ON FOUR STRINGS USING TWO INVERTERS. [INVERTERS: POWER-ONE # AURORA PVI-3.5-I-OUTD-S-US-NEG \\\ AND  POWER-ONE # AURORA PVI-6000-OUTD-US |||| MODULES: TRINA SOLAR # TSM-240PA05]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38677	14041-20000-06144	5015 N BALBOA BLVD #101-#410	91316	5	171B133   627	2258016004	(T)(Q)R3-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Apartment			03/06/2014 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.16219	-118.50134	New fully sprinkler 4-story, 42 unit apartment with two level basement garage.  New 2000A service.  Plan check for power and energy.Note: Due to pre-printed check, additional plan check fee is required for Title 24 for addition 54240 s.f.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38678	19041-20000-49836	22605 W CANTARA ST	91304	3	189B097    72	2013006023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Issued	12/04/2019 12:00:00 AM	PIN	34.2179428	-118.61929916	Plan check for PV roof mounted system, PV system size: 2.925KW  DC, 3.8KW AC with 9 PV Modules and 1 inverer(3.58KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38679	10041-10000-16634	2701 E CESAR E CHAVEZ AVE	90033	14	127-5A225  20	5177032024	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2037.20, 2042.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.0452	-118.20376	"Ti in a ""Jack in The box"" restaurant. Plan check for T24 and Energy."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38680	13041-20000-33076	18825 W BRASILIA DR	91326	12	213B121    53	2872014021	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.28409	-118.54271	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8 KWAC. 18 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38681	15041-10000-28087	11430 W BURBANK BLVD	91601	2	174B169   840	2350004034	C4-1, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Public Safety Only			08/26/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.17184	-118.38	NEW FIRE WARNING SYSTEM FOR 125 UNITS APT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38682	16041-10001-41263	3345 W WILSHIRE BLVD 1ST FL	90010	10	132B197    22	5502028020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.06193	-118.2963	REVISIONS TO THE LIGHTING SYSTEM ON THE 1ST FLOOR- LUMINAIRES CHANGED TO LED TYPE; NEW PANEL BOARD 225A AND NEW CKTS; INCREASED AREA  PLAN CHECK ONLY(((((((PC FOR POWER AND ENERGY.  ADAPTIVE REUSE CONVERSION OF A 12 STORY OFFICE BLDG TO 202 LIVE-WORK UNITS. 9 TYPICAL UNITS. EXISTING SERVICE.  TOTAL AREA  58292 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38683	17041-10000-12648	929 W ANAHEIM ST	90744	15	030B205   419	7416013028	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.77948	-118.2739	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 13,500 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38684	16041-10000-44759	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR STATION  A NEW 34.5KV SERVICE RATED 1200A  IN THE CUSTOMER'S  LOCATION,  CONDUIT ALSO PROVIDED FROM THE NEW EQUIPMENT TO UTILITY END. ALL NEW WORK IN FUTURE WILL BE RECHECKED WITH NEW FAULT CURRENT, THE NEW 34.5KV SERVICE EQUIPMENT, AND THE GROUNDING DETAIL.NOTE. THE WHOLE SCOPE IS INVOLVED WITH CONDUIT ONLY, NO FEEDER DETAIL IS  INCLUDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38685	19041-10000-28734	445 S FIGUEROA ST 29TH FL	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Issued	10/24/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	ENERGY PLAN CHECK FOR AN OFFICE CORRIDOR/RESTROOMS T.I LOCATED ON THE 29TH FLOOR OF A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF  1986-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38686	19041-10000-29716	2828 E 12TH ST #102	90023	14	120A221   201	5169009007	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.02097	-118.21839	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38687	16041-10000-42695	2330 W RIPPLE ST	90039	13	150A211    79	5437032015	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.10672	-118.25294	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total sqft = 63200	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38688	17041-10000-05859	4578 W BRAZIL ST	90039	13	165B201   241	5593011050	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.14672	-118.27527	Plan check for new fire alarm system in existing building. Total fire alarm devices: 60 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38689	16041-10000-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	05/10/2021 12:00:00 AM	ADDRESS	34.04771	-118.46271	Plan check power and energy T.I.  Outpatient Medical office Building Cedars-Sinai 2nd, 3rd, and portion of 1st and lobby level Floor. Change of use from office to outpatient medical users, no critical care area. Total area under the SOW for two address: 41,236 sq ft.  There are 2 addresses on one building. B#16016-10000-27229(Fire Alarm and Low voltage are not subject to this plan check)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38690	15041-20001-35922	10450 N DE SOTO AVE	91311	12	207B109   628	2706015033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	ADDRESS	34.26047	-118.58835	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 13 kWac and consists of (2) inverters, (48) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38691	19041-20000-17659	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2342.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	01/06/2022 12:00:00 AM	ADDRESS	34.02198	-118.33376	New fire alarm system for 2-story commercial office building.  (68) signaling line and notification appliance devices, (2) remote power supplies, and FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38692	14041-20000-27288	17424 W CUMPSTON ST	91316	5	171B129    24	2257010055	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM			Reviewed by Supervisor	10/15/2014 12:00:00 AM	ADDRESS	34.1689	-118.51284	PV1.  Install 5.50 kW roof-mounted, utility-interactive PV system.  AC Modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38693	18041-20000-40235	6936 N PEACH AVE	91406	6	183B145   480	2234024027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			PC Approved	10/27/2018 12:00:00 AM	ADDRESS	34.19675	-118.46824	PV1.  Install 12.96 kW roof mounted grid tied PV system.  (36) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38694	15041-10000-05238	10045 S WESTERN AVE	90047	8	091-5A193 170	6058006007	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	33.94405	-118.3093	New fire alam system for a single story commercial building, project including (1) fire alarm panel, (1) power supply, and (49) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38695	12041-20000-27028	15711 W ROSCOE BLVD	91343	12	192B141   377	2673014066	R3-1, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.22222	-118.47484	Plan check for outdoor energy only. 2700sqft. Motel 6. Outdoor lighting pole is required by LAPD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38696	18041-10000-30755	870 S HILGARD AVE 1-77	90024	5	135B153   384	4360007028	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.06469	-118.4407	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 237 FA DEVICES, AND 7 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38697	14041-20000-15110	16958 W ENCINO HILLS DR	91436	5	159B133    63	2287005058	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.13503	-118.50216	PV1Microinverter standard plan. Install microinverter solar array system on roof of SFD. System size: 5.8kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38698	15041-10000-38556	20790 W NORDHOFF ST	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT. (THE SHELL WAS BUILD FOR RETAIL PUROSE). TOTAL AREA 1254 SQ FT.B# 15016-10000-23306	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38699	15041-10000-03979	635 W CRESTMOORE PL	90291	11	108B149  1435	4237012002	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Expired	04/06/2017 12:00:00 AM	PIN	33.98921101	-118.45637675	PV1, INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERECONNECT WITH MAIN SERVICE PANEL.(10) MODULES: YINGLI # YL255P-29B(1) INVERTER: ABB #PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38700	17041-10000-16721	10334 N ORO VISTA AVE	91040	7	204B189   392	2560013007	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			Verifications in Progress	06/13/2017 12:00:00 AM	ADDRESS	34.25711	-118.31562	Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  6 kWac inverter connected to 5 kW 13.5 kWH battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38701	17041-10005-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	SUPP. PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER BULLETIN 12 (BANC OF CALIFORNIA EXPERIANCE CENTER) UNDER DELTA 9. SCOPE INCLUDES REVISIONS TO LIGHTING INCLUDING T-24 FORMS REVISIONS,  ADDITION AND REMOVAL OF CIRCUITRY INCLUDING REVISIONS TO PANEL SCHEDULES TO REFLECT CORRECT LOADING AND ADDITION OF EQUIPMENT   THIS APPLICATION COVERS PERMITS ELEMENTS FOR BULLETIN 9,11,12 (UNDER DELTA 7, 8,9)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38702	17041-10001-16302	1723-1725 N IVAR AVE	90028	13	148-5A187  86	5546005016	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.10239	-118.32831	DELTA 2 & 3 CHANGES TO THE APPROVED PLANS. INSTALL 28 NEW CIRCUITS AND A NEW EMPTY PANEL FOR FUTURE LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38703	17041-20000-22217	900 N STRADELLA ROAD	90077	5	141B149    25	4370003020	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.08646	-118.45123	service upgrade to an existing sfd 1200 amp service.  plan check for power only. this is plan check only.electrical fees paid under building combo permit reference 14014-30000-05206.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38704	16041-10000-45548	2727 W SAN FERNANDO ROAD	90065	1	150B213   224	5457007031	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.11011	-118.24246	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures for exterior and interior lighting. Total affected area is 5800 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38705	17041-20000-23540	2208 N STRADELLA ROAD	90077	5	153B145   195	4377030002	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2017 12:00:00 AM			Reviewed by Supervisor	07/25/2017 12:00:00 AM	ADDRESS	34.11283	-118.46263	5KW ENERGY STORAGE SYST.  + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.12 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38706	14041-20000-05390	515 S FIGUEROA ST 2050	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM			Not Ready to Issue	03/12/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	T.I. to a high rise building on portion of 4th floor, Suite 2050.  Install general lighting. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38707	17041-10000-34448	20500 W SHERMAN WAY	91306	3	183B109   104	2137001020	[Q]C4-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.20084	-118.58003	REMOVE METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38708	16041-20001-04874	20754 W LUGANO WAY	91326	12	213B109   283	2701065001	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.27826	-118.58526	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (46) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38709	14041-20000-21430	8822 N HAYVENHURST AVE	91343	12	195B137   546	2688034005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.23091	-118.49367	PV1.  Install 3.57 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38710	16041-10001-34522	4534 N DULCINEA CT	91364	3	165B101   168	2173015003	RE15-1-RPD-2.9-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2016 12:00:00 AM			Reviewed by Supervisor	10/13/2016 12:00:00 AM	ADDRESS	34.15048	-118.60627	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.20KWac.(35)AC MODULES-SUNPOWER E20-327C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38711	15041-20000-02779	12476 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	33.97888	-118.41041	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38712	18041-20000-11408	11317 N RIVERWOOD TER	91040	7	210B189    33	2551007003	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District, Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Issued	10/25/2018 12:00:00 AM	ADDRESS	34.27421	-118.31883	Plan check for a PV1 ground-mounted PV system. System size is 10.38 kWdc/10.07 kWac-CEC and consists of (2) inverters, (38) modules, and (1) load center.Note: Building permit has been issued under 18020-20000-00845	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38713	19041-20000-30529	6050 N ELLENVIEW AVE	91367	3	177B085   282	2032015025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.1812	-118.65949	$0 per AB1414 ordinance.NEW ROOF MOUNTED 16.38 KW PV SYSTEM WITH 52 @ PV PANELS, 2 @ POWER WALLS AND 2 INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38714	14041-20000-01866	8144 N RANCHITO AVE	91402	6	192B153  1137	2213010002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.21912	-118.43613	pv1 single family dwelling. total system size 5kw ac using 22 modules. using transformerless inverters with power optmizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38715	19041-10000-16956	4959 W ADAMS BLVD	90016	10	123B181   980	5049008043	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.03269	-118.34846	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38716	19041-20001-36638	6300 N RANDI AVE	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18466	-118.61011	Expedite per applicant requst. Plan check for PV roof mounted system, System size: 26.535KW DC, 23.6KW AC with 61 PV Modules and 2 inverter(14.4KW  and 9KW )Applicant request: %%%%%%    Plan stay Van Nuys  %%%%%%%%Note: This is 12 buildings on 1 Plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38717	12041-20000-14369	15315-15321 W RAYEN ST	91343	7	195B145   245	2654005026	M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.232	-118.46599	New srvice to supply remodeled office space.  Inspector to verify the the service entrance conductors have been installed to remain outside of the building as in CEC 230.6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38718	11041-10000-03520	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	05/27/2011 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	PIN	33.93847109	-118.41935625	Ti in continental Hangar area in LAX. New switchboards and panel boards. EPC is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38719	14041-10000-11910	1023 S VICTORIA AVE	90019	10	132B189  1105	5082019002	R1-1-O	Central	Wilshire	Olympic Park		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.05452	-118.32462	PV1 7.31KWAC. 240V. microinverter. STD. 1story. Roofmount. [(34) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(34)modules: {TOPSUN TS-S250}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38720	19041-10000-03769	2605 W OLYMPIC BLVD	90006	1	129B197   209	5076003016	C2-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.05257	-118.28837	Remove HID fixture and replace with new LED fixture - T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38721	09041-10003-15492				148-5A189 280	5546029024	[Q]C4-2-SN		Hollywood	Central Hollywood			Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM			PC Approved	06/10/2010 12:00:00 AM				New tenant to core/shell - Applicant indicates space will go through change of use - Wells Fargo Bank (Unit 2A) - Permit is for new panels, new XFMRs, new equipment, new ckts, new lighting.  P/C is for Power and energy.((((((((((((((( changes made to previously approved set changed 6 ac to 8 ac units , one water heater and one emergency lighting. 6-10-10))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38722	16041-20000-39141	12020 W CHANDLER BLVD 4th Floor	91607	2	171B165   117	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.16825	-118.39512	Plan check for energy only. TI to 4th floor offices in existing commercial building. New lighting (incl. emergency) and receptacles. 27,386sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38723	14041-10000-23133	1225 S 4TH AVE	90019	10	129B189   773	5081013005	RD1.5-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Expired	09/28/2016 12:00:00 AM	ADDRESS	34.04882	-118.3208	PV1 5.5KWdc. 240V. positive GND. STD. 2story. Roofmount. [(22) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(22)modules: {Renesola {JC250S-24/BB-b}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38724	15041-10000-18356	6121 W SUNSET BLVD #150	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	IN EXISTING SPACE, OPENED A NEW COFFEE STORE.  CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE ADDITION OF LIGHTS AND REVISIONS TO ENERGY CALS WITH THE ADDITION OF ONE PANEL.  REFRENCE APLLICATION NUMBER 14041-1000-33236 FOR MASTER PERMIT.  PLAN CHK IS FOR TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38725	14041-10003-13430	903 S NEW HAMPSHIRE AVE 1-16	90006	10	132B197   836	5094025002	(T)(Q)R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	34.05572	-118.29316	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO MAIN SWITCH REMOVAL, REVISE LOADS OF SUMP PUMPS AND UPDATED FLOOR PLANS. PC ONLY. PERMIT COVERED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38726	14041-10000-09952	612 N FULLER AVE	90036	5	141B181   820	5526021018	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.08221	-118.34969	LEVEL 4 METHANE MITIGATION SYSTEM.  Methane standard plan being used for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38727	11041-10000-13504	153 N GLENDALE BLVD 1-4	90026	13	135A209   300	5159015032	C2-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM			PC Info Complete	11/04/2011 12:00:00 AM	ADDRESS	34.06346	-118.26018	NEW METHANE DETECTION SYSTEM FOR A NEW 3-STORY APARTMENT BUILDING.permit for this job was covered under electrical/fire alarm permits. this is a plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38728	17041-10000-05006	660 S FIGUEROA ST STE 1140	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR ENERGY. T.I.  FOR  (E) OFFICE SUITE TOTAL AREA 2094 SQ FT.Permit was pulled under Application Number: 17041-10000-00342B #16016-10000-29257	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38729	11041-20000-15694	9221 N CORBIN AVE suite 190	91324	12	198B117   166	2761001073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.23786	-118.56248	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38730	17041-20001-25141	14122 W PINE LANE	91405	2	183B153  1171	2217032037	(T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM			Reviewed by Supervisor	08/02/2017 12:00:00 AM	ADDRESS	34.20141	-118.44096	expeditepv1install roof mounted pv system sized 3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38731	17041-20000-44769	1901 S BUNDY DR	90025	11	123B149   330	4259018014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.03497	-118.45709	Plan check for energy only. TI to office - new lighting (incl. emergency). New sound editing rooms. 2,860sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38732	18041-20000-31379	17353 W BOSWELL PL	91344	12	222B129    91	2602011029	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.30469	-118.51219	Plan check for PV roof mounted system, system size: 11.5KW DC, 10.78KW AC CEC with 1 inverter(10.0KW) and 35 PV Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38733	15041-10001-04941	2800 W OLYMPIC BLVD	90006	10	129B197   235	5078013028	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			11/18/2015 12:00:00 AM			PC Info Complete	10/27/2016 12:00:00 AM	ADDRESS	34.05242	-118.2951	Plan check for power and energy for new mixed-use apartment building with 4 stories apartment dwelling units. 69 unit apartment with 2500A-rated 208Y/120 service.((((((((((   M.Z    addition of one extera apartment  from 69 to 70 units.   11-18-15))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38734	13041-10000-04308	5656 W MANCHESTER AVE	90045	11	096B169   549	4125018014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	33.95972	-118.38021	NEW CONSTRUCTION OF RETAIL SPACE.TOTAL AREA OF OUTDOOR 34407SQ FT. PC FOR POWER AND ENERGY OF OUTDOOR LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38735	13041-20000-13378	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.10191	-118.28217	T24 FOR EXISTING OFFICE ROOMS 125A, 125B, 125C, 125D, 118, 117. TOTAL SQRFT 1506. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38736	17041-30000-36664	601 S FIGUEROA ST #2050	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing space office T.I. Total area: 4265 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38737	18041-20000-14792	1134 E GRANT AVE	90291	11	108B149  1092	4237028011	R2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/14/2018 12:00:00 AM	ADDRESS	33.9908	-118.4498	TESLA POWERWALL TO AN EXISTING PV SYSTEM.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38738	17041-10000-09763	20555 W SUPERIOR ST	91311	12	201B109   222	2748005050	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.24646	-118.58155	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 16625 SQ. INDOOR/OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38739	19041-10000-02061	4838 N TYRONE AVE	91423	4	168B153   292	2248027005	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Issued	01/17/2019 12:00:00 AM	ADDRESS	34.15875	-118.4442	Plan check for a 5KW AC PV1 roof mounted system with (18) modules and (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38740	10041-20001-25619	8300 N VAN NUYS BLVD	91402	6	192B149   361	2638022044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM			PC Approved	06/28/2011 12:00:00 AM	ADDRESS	34.22189	-118.44858	PLAN CHECK ONLY. REVISION TO APPROVED DELTA 6. CHANGE FROM 125A BREAKER TO 100A BREAKER FOR PANEL C SUPPLIED FROM PANEL A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38741	16041-10001-37618	18250 W ROSCOE BLVD	91325	12	192B125   681	2102022034	C1-1VL, R1P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.22064	-118.53113	CHANGES TO APPROVED SET OF PLANS. LAYOUT CHANGE AND FIXTURE TYPE CHANGE. UPDATED FLOOR PLANS AND T24 DOCUMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38742	16041-10000-05077	21900 W ARMINTA ST	91304	3	189B105   337	2110010005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.21357	-118.60393	PV1. roof mounted installation to a single family home with a central inverter of 7.6 kWac and 29 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38743	14041-10000-17510	5757 W CENTURY BLVD SUITE 575	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Issued	07/21/2014 12:00:00 AM	ADDRESS	33.9457	-118.38274	TITLE 24 FOR TENANT IMPROVEMENTSAREA = 7200INSTALLATION OF LIGHTING AND RECEPTICALS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38744	15041-10001-03555	1030 N AMALFI DR	90272	11	129B133   305	4425011005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	ADDRESS	34.04748	-118.50883	Expedite per applicant request((((Plan check for PV1 roof mounted 9.69kW system  with 28 modules and 2 inverters))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38745	15041-10000-18685	12602 W MOORPARK ST 1-8	91604	2	165B161   336	2375003013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.15013	-118.40755	New fire alarm system for a 4-story, 8-unit apartment; Scope includes (1) Fire alarm panel, and (34) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38746	11041-10000-15087	7503 S EARLDOM AVE	90293	11	093B153   118	4117029002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2011 12:00:00 AM	08/09/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	33.95357	-118.44313	New 1.380 KW roof mounted PV system using ENPHASE M215 microinverters.  Variance has been issued,  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38747	16041-10000-07312	700 N HIGHLAND AVE	90038	4	141B185   566	5524011014	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	03/15/2018 12:00:00 AM		Issued	03/15/2018 12:00:00 AM	ADDRESS	34.08375	-118.33839	PC FOR POWER AND ENERGY FOR A NEW 3-STORY W/ MEZZ  MIXED-USE BUILDING  W/ 19 APARTMENT UNITS OVER GRADE LEVEL RESTAURANT  AND PARKING OVER 1 LEVEL BASEMENT  PARKING. SCOPE INCLUDES NEW 2000A 120/208V 3 PHASE 4W SERVICE. TOTAL AFFECTED AREA IS 27,736 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38748	18041-20000-43574	12632 W SUNSET BLVD	90049	11	132B141   565	4405028017	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.05702	-118.48405	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 15.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38749	15041-20000-11106	900 S CRENSHAW BLVD	90019	4	132B189   898	5092003027	CR-1VL	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			04/14/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.05612	-118.32202	Plan check for new fire alarm system(New Appartment 31 unit) Total fire alarm device: 94 devices. Submit back room b/c complicated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38750	12041-20001-23550	5112 W HOLLYWOOD BLVD 105-107	90027	13	148-5A195 108	5544013069	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM			PC Approved	12/29/2015 12:00:00 AM	ADDRESS	34.10159	-118.30108	Supplemental change on anapproved set, change on lighting fixture. Permit under 12041-10000-23550*****Combining space from an adjacent hair salon (#105) and adding to an existing restaurant (#106-107).  Load is less than 200 Amps, and occupancy load is 88.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38751	14041-10001-16145	2644 E ROSEVIEW AVE PV2-APT4	90065	1	145-5A217  90	5453003054	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.09342	-118.22769	(((8/15/2014 - Supp. app. for plan check for roof mounted solar PV array at request of inspector.  Plan was originally submitted to express permit.  Main service panel is 600A. Type changed to apartment. PLAN CHECK ONLY)))Master permit work description: INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 2.04KW. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. ***APT. # 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38752	15041-20000-39560	4776 N NOMAD DR	91364	3	168B113   189	2175039004	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.1578	-118.56737	PV1. Install roof mounted PV system sized 15 kW. Interconnected with main service panel. (50) Sunpower SPR-327 Modules(3) SMA SB5000 TL InvertersNOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38753	14041-20000-15866	10800 W BURBANK BLVD	91601	2	174B177   586	2416014013	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.17194	-118.36614	New 8 unit of industrial building in Methane Buffer Zone.  Install new 1200A service, panels, branch circuits, and lighting.  Plan check for power and energy.Note: Plan in accordance to 2008 NEC due to the building submittal date.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38754	17041-10000-28892	6050 W JEFFERSON BLVD	90016	10	117B169     7	4204008011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		7025.02	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.02066	-118.38059	PC FOR METHANE MITIGATION SYSTEM (LEVEL 5)SCOPE INCLUDES PANEL AND 14 DEVICES WITH ADD. BLOWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38755	12041-10000-07794	221 N FIGUEROA ST # 1600	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.05882	-118.25099	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE TENANT IMPROVEMENTS ON THE 16TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38756	16041-10001-14710	10066 N VANALDEN AVE	91324	12	204B121   430	2729004004	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			PC Approved	05/02/2016 12:00:00 AM	ADDRESS	34.2533	-118.54899	PV1, rooftop solar installation 16.4 kW AC system.    (74) CS6P-265P     (1) SE 11400A-US       (1)  SE5000P300 is used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38757	18041-20000-26393	3732 W CLAYTON AVE	90027	4	148-5A203 330	5430009015	R1-1	Central	Hollywood	Los Feliz	Yes	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.10052	-118.27558	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.(22) solar city 325W modules(1) delta solivia 7600 string inverter(1) tesla energy storage device 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38758	16041-10000-24464	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Expired	10/04/2019 12:00:00 AM	ADDRESS	34.09818	-118.35187	FULL PC FOR POWER AND ENERGY FOR A GUITAR CENTER. TI, NEW INTERIOR DESIGN. ALL NEW CIRCUITS AND REVISED PANEL LOCATIONS. TOTAL AFFECTED AREA IS 16017 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38759	15041-20000-29394	5718 N VINELAND AVE	91601	2	174B173   553	2415004005	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Expired	10/06/2017 12:00:00 AM	ADDRESS	34.17457	-118.37014	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter, and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38760	11041-10000-26854	3641 S WATT WAY	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	ADDRESS	34.02033	-118.28801	Remodel to USC Labratory on the 3rd and 5th floors.  Lighting change, receptacles, and equipment added.  New 400A feeder for a portable standby generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38761	15041-20000-26783	2111 W 29TH ST	90018	10	123B193  1156	5052028035	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.02925	-118.31261	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel. (14) SolarWorld SW 320 (14) Solar Edgeg Power Optimizer P400(1) Solaredge SE3800 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38762	17041-10000-36799	1060 W EXPOSITION BLVD	90037	8	117B197   516	5037015030	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM				PC FOR FIRST TIME TENANT MEDICAL TI  AN **OSHPAD-3**  CLINIC .SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTINGTOTAL AFFECTED AREA 4660 INDOOR AND ?? OUTDOOR (PLANCHECKER TO VERIFY OUTDOOR)B# 16010-10001-04056	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38763	18041-20001-20184	5327 N DONNA AVE	91356	3	171B121   147	2163022027	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.16783	-118.54858	supplemental for fee expeditePlan check for a PV1 roof-mounted PV system. System size is 10.4KVA consisting of (2) inverter - solivia 5.2TL, (38) modules, and (1) load centers. with battery backup system under supplemental	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38764	12041-20000-21241	701 E CESAR CHAVEZ BLVD 212	90012										Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM			Reviewed by Supervisor	09/17/2012 12:00:00 AM				fire alarm system wallmart grocery new building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38765	16041-10000-00500	2001 W JOHN S GIBSON BLVD	90731	15	024B201    45	7440016911	[Q]M3-1VL	Harbor	Port of Los Angeles	Northwest San Pedro	YES	9800.31	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	33.75887	-118.28777	New Fire alarm & Mass Notification system on (E) commercial build. (144) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38766	12041-20000-11294	17648 W VENTURA BLVD	91316	5	171B129   390	2290010012	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM			PC Approved	05/16/2012 12:00:00 AM	ADDRESS	34.16205	-118.51785	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38767	13041-10000-19184	1500 E ANAHEIM ST	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	33.78074	-118.24357	Methane mitigation system for 2-story commercial union hall.  42 devices.  Active system, level IV.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38768	19041-20000-51430	11200 W PICO BLVD	90064	5	123B153   155	4256010012	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	07/01/2020 12:00:00 AM		Permit Finaled	09/15/2021 12:00:00 AM	ADDRESS	34.03581	-118.43706	$0 Permit fee due to SB1222 and AB1414PV3.  Install 226.4 kW DC roof mounted PV system.  (566) modules with (9) 20 kW inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38769	19041-10000-07831	5842 W CARLTON WAY	90028	13	148-5A191 256	5545010004	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			03/05/2019 12:00:00 AM			PC Approved	03/09/2019 12:00:00 AM	ADDRESS	34.10034	-118.31725	"DELTA ""A"" CHANGES TO APPROVED PLANS. MASTER APPLICATION UNDER 17041-10000-13255. APARTMENTS ARE SUBDIVIDED INTO BEDROOM/BATHROOMS SHARING A KITCHEN, LIVING/DINING ROOM. THE CENTRAL HVAC FOR EACH APT IS REPLACED WITH INDIVIDUAL HVAC FOR EACH BEDROOM OF EACH APT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38770	19041-10000-42895	1901 E GRANT ST	90744	15	033B213   271	7428006005	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	06/18/2021 12:00:00 AM	ADDRESS	33.78512	-118.23922	FULL PLAN CHECK. (SHELL HYDROGEN FUELING STATION) ELECTRICAL SYSTEM. SYSTEM CONSIST OF A 1200A 277/480VAC 3PH 4W SERVICE FEEDING TWO STATION MODULES A AND B AND FUTURE LOADS TO BE PERMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38771	16041-20000-32072	10339 N TUJUNGA CANYON BLVD	91042	7	204B197   670	2558020015	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Issued	09/09/2016 12:00:00 AM	ADDRESS	34.25702	-118.29165	INSTALL ROOF MOUNTED PV SYSTEM ON SFD SIZED 3KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38772	12041-20000-22363	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	34.04804	-118.46227	T.I. to an existing office, change to lighting.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, No emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38773	16041-10000-25318	629 W 85TH ST	90044	8	097-5A201 156	6032018051	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Expired	08/27/2018 12:00:00 AM	ADDRESS	33.96122	-118.28493	PV2 COMMERCIAL ROOFTOP. ON APARTMENT UNIT. PC FOR 3KW AC USING 8 MODULES IN TOTAL. SYSTEM IS INTERCONNECTED TO UNIT 629 1/2 W 85TH. SYSTEM IS ROOFTOP MOUNTED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38774	19041-10000-15881	100 S GRAND AVE	90012	14	132A211    94	5149021***		Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	09/21/2023 12:00:00 AM	ADDRESS	34.05536	-118.24876	NEW FIRE ALARM SYSTEM IN A HIGH RISE BULDING WITH 5,100 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38775	19041-10001-32655	5757 W CENTURY BLVD #200B	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	33.9457	-118.38274	PLAN CHECK ONLY FOR LOST SET OF APPROVED PLANS, PERMIT HAS NOT BEEN PULLED YET. ORIGINAL SCOPE OF WORK IS A T-24 PLAN CHECK FOR A TI. SCOPE INCLUDES NEW RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1,245 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38776	14041-10000-13838	14006 W RIVERSIDE DR #249	91423	4	168B153   454	2269025004	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	permit to be pulled at EPC counter only. Plan check for energy only.  TI retail to restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38777	19041-20001-00303	7501 N GLENOAKS BLVD	91504	2	186B181   296	2401042013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1021.04	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	34.20677	-118.34209	PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLYti to an existing commercial building (hotel).  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38778	14041-20001-19531	17544 W RAYMER ST	91325	12	192B129    70	2787024012	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM			PC Approved	07/28/2014 12:00:00 AM	ADDRESS	34.22619	-118.51743	Changes from previous approval.  Downsize PV system by removing one module.  All permit is under the original application.Note: Plan check is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****14.28 KW PV1 roof-mounted system; changes from  previous approval plan ( 14041-20000-13007), changing from (42) Trina Solar TSM-255p to (56) TSM-255p module and (2) Power One Aurora PVI3.6-OUTD to Power One Aurora PVI6000 and 5000-OUTD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38779	19041-20000-42207	615 N NORTH FARING ROAD	90077	5	144B153   936	4358002018	RE20-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	12/21/2020 12:00:00 AM		Permit Finaled	08/15/2023 12:00:00 AM	ADDRESS	34.08769	-118.43448	800A 240/120V 1ph-3w service. Scope of work includes (1) main distribution board and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38780	18041-20001-38825	20105 W RINALDI ST #100-110	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Closed	08/05/2022 12:00:00 AM	ADDRESS	34.27543	-118.57209	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. SCOPE OF CHANGES INCLUDE ADDITION OF A NEW 400A PANEL, PANEL SCHEDULE ADDITION, MINOR CHANGE TO POWER FLOOR PLAN, AND CIRCUIT BREAKER SIZE CHANGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38781	19041-10000-48199	1125 S CRENSHAW BLVD	90019	10	129B189   276	5082026027	C2-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	34.05233	-118.32448	PC FOR POWER AND ENERGY FOR AN EXISTING SPACE.  SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 10307 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38782	13041-10000-25750	8725 N OLAND AVE	91352	2	195B177   453	2404029015	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.22819	-118.35841	PV1.  Install 7.5 kW DC roof-mounted solar array, interconnect with main service panel.  Central inverter: Fronius IG Plus V 7.5; 30 modules: Trina Solar TSM-250PA05.18	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38783	19041-20000-48764	2241 N CHISLEHURST DR	90027	4	150B197    84	5588004020	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.11091	-118.2995	PV1. INSTALL 8.06 KW DC PV SYSTEM WITH (26) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38784	14041-20000-31604	13305 N NORRIS AVE	91342	7	225B145   242	2501010054	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.31274	-118.46639	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.7KW INTERCONNECTED WITH MSP.(22) SUNMODULES SW270 MODULES(22) ENPHASE 215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38785	14041-10000-22827	18503 W DEVONSHIRE ST	91326	12	204B125   153	2728028007	C2-1VL, [T][Q]C2-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	PIN	34.25764367	-118.53671801	T24. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 1080 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38786	17041-20000-41184	1553 N SCHRADER BLVD	90028	13	148-5A187 334	5547018029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	09/21/2020 12:00:00 AM	ADDRESS	34.09953	-118.33258	PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVMENT TO CONVERT THE (E) APARTMENTS TO GUESTROOMS, AREA OF WORK IS 12,000 SQ. FT.BUILDING PERMIT # 17016-20000-33799	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38787	17041-10000-32046	11677 W SAN VICENTE BLVD #315	90049	11	132B145   497	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.05404	-118.46492	TI TO RESTAURANT. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38788	17041-10000-29975	21018 W KESWICK ST	91304	3	186B105    28	2109020014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.21015	-118.59135	PC for new rooftop solar for single family. PC for new 3.08kW system with 11 modules and microvinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38789	11041-10000-19620	11265 W MORRISON ST	91601	2	171B173  1194	2353013054	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			09/15/2011 12:00:00 AM	09/15/2011 12:00:00 AM		Permit Expired	10/08/2013 12:00:00 AM	ADDRESS	34.16094	-118.37677	REPLACE AN EXISTING DAMAGED FIRE ALARM / MONITORING PANEL. ALL DEVICES ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38790	11041-10000-05510	1101 S MAIN ST	90291	11	108A143   130	4238001046	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Apartment			03/21/2011 12:00:00 AM			Corrections Issued	04/22/2011 12:00:00 AM	ADDRESS	33.99114	-118.4735	NEW 2500 AMP SERVICE, 1 HOUSE PANEL.  I NEW SWITCH BOARD.  THIS WILL BE FOR A 45 UNIT APARTMENT BUILDING TO BE BUILT IN THE FUTURE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38791	13041-20000-35474	2665 N ROUND DR	90032	14	139-5A235 128	5217014011	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Expired	01/13/2016 12:00:00 AM	ADDRESS	34.07743	-118.17311	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38792	17041-20000-32172	10701 W LONGFORD ST	91342	7	213B177   137	2529016014	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.27793	-118.36355	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.67 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38793	12041-10001-14313	8501 S PERSHING DR # 3	90293	11	096B153  1024	4116024033	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM			PC Approved	01/07/2013 12:00:00 AM	ADDRESS	33.95597	-118.44237	[[[[[Plan check only supplemental to 12041-20000-14313]]]]]      T-24 lighting plan check for remodeled restaurant in space 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38794	14041-20000-33442	19534 W VANOWEN ST	91335	3	180B117    23	2132001007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.19362	-118.55912	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system.12  327W pv modules across two strings (5+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38795	16041-20000-12881	1515 W 190TH ST Ste 560	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Expired	08/28/2018 12:00:00 AM	ADDRESS	33.85852	-118.30531	Existing commercial office remodel in (E) commercial lowrise building.  All new lights and existing circuits.  Plan check for energy.  3543 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38796	17041-10000-09835	1640 W 190TH ST	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	33.85814	-118.30849	PC for energy only, Indoor Tilte-24. Replacing existing lighting with new LED Lights on existing wherehouse. Area: 64,510.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38797	15041-10001-39033	1221 W 3RD ST	90026	1	132A209    74	5152013019	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Apartment			11/18/2015 12:00:00 AM			PC Approved	01/19/2016 12:00:00 AM	PIN	34.05725872	-118.25842757	(((EXPEDITE FEES)))PV2 ROOF MOUNTED 271 KWAC TRANSFORMERLESS 1000VDC 3P 480V INVERTER OUTPUT. 1020 MODULES AND 13 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38798	14041-10000-23698	21901 W ERWIN ST	91367	3	177B105    24	2146029004	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.18301	-118.60425	PLAN CHECK FOR POWER AND ENERGY ON A COMPLETE REMODEL OF A McDONALD RESTAURANT AND DRIVE THROUGH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38799	15041-20000-28578	2111 S BROADWAY	90007	9	123A205   199	5126032015	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.02913	-118.26753	PV2. Install roof mounted PV system sized 3.4 kW on an existing commercial building. Connecting to line of disconnect lugs (line side tap). Ungrounded system.(14) Solar World SW 285 Modules(14) Enphase M250 Modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38800	17041-10000-41023	858 S MANNING AVE	90024	5	135B153   379	4360013013	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.06491	-118.43767	PC for 6kW rooftop solar. Installing one central inverter and 21 modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38801	17041-10000-07548	16900 W VENTURA BLVD	91316	5	168B133   151	2289001016	C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.15918	-118.5017	PC FOR ENERGY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL ARAE 12900 SQ FT. /OUTDOOR/	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38802	11041-20000-18455	9505 W LANIA LANE Rec. Bldg	90210	5	150B165   197	4387027008	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2011 12:00:00 AM	02/15/2012 12:00:00 AM		Issued	02/15/2012 12:00:00 AM	ADDRESS	34.10546	-118.40392	Plan check for installation new 600A distribution board, panels, equipment, and ckts for new recreational building being supplied from 2000A service at single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38803	17041-10000-35136	6677 W SANTA MONICA BLVD	90038	4	144B185   674	5532022010	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	10/26/2020 12:00:00 AM	ADDRESS	34.09085	-118.33573	Install new Fire Alarm system on a New 8 story mixed used building. (59) panels (3026) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38804	18041-10001-08458	312 S ALAMEDA ST ste 102	90013	14	127-5A215  66	5163010009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04494	-118.23784	PC FOR CHNAGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE INCLUDES REVISION TO ELECTRICAL METERING FROM SINGLE METER AT 400A TO 2 METERS 200A EACH.  ALSO COVERING TITLE 24 COMPLIANCE. PERMIT UNDER THIS SUBMITTEL IS FOR ADDITIONAL PANEL AND CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38805	12041-20001-11570	11507 W OXNARD ST	91606	2	177B169   797	2338004001	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.1796	-118.38271	((CHANGES MADE TO APPROVED SET OF PLANS. SERVICE RELOCATION, ADDED NEW SUB PANEL, NEW LOADS ON EXISTING PANEL, NEW TITLE 24.)))New mixed use commerical building with medical offices, offices, and retail spaces.  Check for interior and exterior energy and electrical.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38806	15041-20000-34509	16463 W BOSQUE DR	91436	5	165B137   495	2291017028	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.14544	-118.49232	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.PV1. NEW SOLAR SYSTEM ON A RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.2KWac.(54)MODULES-SUNEDISON MODEL#SE-F325BZC-3Y(2)INVERTERS-SOLAREDGE 7.6W INVERTER MODEL#SE7600A-US(54) OPTIMIZERS-SOLAREDGE POWER OPTIMIZER #P400	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38807	17041-20000-34652	1640 E MARENGO ST Suite 105	90033	14	133-5A223  37	5201001001	C4-1-CUGU, P-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2033.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.05983	-118.21397	Plan check for Title 24 only. Project site is an suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 831 sq. ft.Note: Building application has been generated under 17016-10000-27655	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38808	14041-10000-09073	6128 S LA CIENEGA BLVD	90056	11	105B173    97	4001005016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	33.98267	-118.37012	PV1, Install 5 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE3800A-US-ZB-U.(20) Modules: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38809	13041-10000-03595	5507 W 77TH ST	90045	11	099B173   261	4127010002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	07/17/2013 12:00:00 AM	ADDRESS	33.96871	-118.37696	PV1 Solar installation for two-story house. Total system size: 2.16 KW. [Microinverter: Enphase Energy Model#: M215-60-2LL-S22] [Solar Module: REC Model#: REC 245 PE]. 10 Modules used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38810	19041-20000-48117	1265 S STEARNS DR	90035	5	129B173   236	5087016013	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Apartment			11/21/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	01/05/2022 12:00:00 AM	ADDRESS	34.05271	-118.37112	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. (1) FA PANEL AND (200) FA DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38811	17041-10001-19864	12454 W WAGNER ST	90066	11	108B157  1522	4221005038	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			Reviewed by Supervisor	06/19/2017 12:00:00 AM	ADDRESS	33.98893	-118.42093	EXPEDITE FEESPC FOR ROOF MOUNTED PV SYSTEM. USING SOLAR TILES. 156 MODULES AND 3.8KW AC INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38812	16041-20000-36555	13267 W FOOTHILL BLVD	91342	7	219B157   153	2513027***	RA-1-CPIO, [Q]RD1.5-1-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	07/19/2020 12:00:00 AM	ADDRESS	34.30099	-118.42289	Plan check for Title 24 only. Project site is community townhomes. Project scope is street lighting. Total lighting area = 164,523 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38813	11041-10000-24779	8480 W BEVERLY BLVD BLDG A	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM	05/30/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.07577	-118.37599	NEW TENANT IMPROVEMENT FOR TARGET STORE  LOCATING IN EXISTING  COMMERCIAL  BUILDING ; NOTE THAT PLAN CHK FEES ARE SIMILAR TO LARGER TARGET STORE PLANS ON 11041-10000-19089. ADJUST FEES AT END OF PLAN REVIEW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38814	14041-20000-10229	6916 N BEVIS AVE	91405	6	183B149   522	2219017021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Expired	05/11/2016 12:00:00 AM	ADDRESS	34.19618	-118.45626	PV1.  Install 6.89 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38815	15041-10000-27492	9014 W NATIONAL BLVD	90034	5	123B169  1171	4311029014	C2-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.03108	-118.39134	PC for energy only, T-24. Remove HID light fixtures and replace with LED fixtures for a commercial bldg. Sq ft = 1200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38816	14041-20000-03572	12136 W MIRANDA ST	91607	2	174B165   459	2340025001	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.1743	-118.39788	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 5.184KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38817	11041-20000-08157	6201 N IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM			No Progress	04/22/2011 12:00:00 AM	PIN	33.93615744	-118.3860948	replacing branch circuits and conduits supplying power to equipment in classified area.  Plan check for power only.Note:  Permit issued under 11041-90000-03321	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38818	14041-10000-14884	12663 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	33.97743	-118.41479	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38819	17041-10000-30124	2002 S SAWTELLE BLVD	90025	11	126B153   696	4261032054	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Info Complete	10/11/2017 12:00:00 AM	ADDRESS	34.04089	-118.44337	void PC FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS, LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1178 SQ.FT.** plan check performed under 18041-30000-46995	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38820	16041-20001-30704	445 S ARDMORE AVE 1-129	90020	10	135B193   591	5503009016	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			08/29/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.06592	-118.30178	*****VOID*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38821	18041-10000-40408	2635 N PASADENA AVE	90031	1	139-5A221  42	5205020022	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Issued	10/23/2018 12:00:00 AM	ADDRESS	34.07776	-118.21553	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38822	13041-20000-08374	4150 N ARCH DR 1st floor-2nd floor	91604	2	162B173   159	2366023018	[Q]R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			04/02/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.1427	-118.37152	Plan check for energy only. 1st and 2nd floor of 4 story apartment (some of 2nd floor lighting is outdoor under existing overhang). Emergency lights are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38823	15041-10000-15984	6307 N BALCOM AVE	91335	5	177B129    67	2123021050	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Expired	08/15/2017 12:00:00 AM	PIN	34.18417958	-118.52030624	PV1, INSTALL 5.89 KW DC ROOF-MOUNTED SOLAR ARRAY ON A RESIDENTIAL HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR 327ne-wht-d(1) INVERTER: ABB PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38824	13041-10000-21228	12200 W VENICE BLVD	90066	11	114B157  1475	4235023001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	05/30/2014 12:00:00 AM		Issued	05/30/2014 12:00:00 AM	ADDRESS	34.0046	-118.43132	UPGRADE OF ELECTRICAL SERVICE FROM 200 TO 800 AMPS. REPLACEMENT OF TENANT PANELS FOR INCREASED FAULT CURRENT. POWER PLAN CHECK. SINGLE STORY. SHOPPING CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38825	16041-20001-00583	11963 W COLLINS ST	91607	2	174B165   473	2340031019	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Approved	01/25/2016 12:00:00 AM	ADDRESS	34.17393	-118.39417	Expedite per applicant request. {{{{{Plan check for PV roof mounted system. System size: 5kW with 20 modules and 20 microinverters.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38826	16041-10001-26794	189 S THE GROVE DR H-2	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	**This is supplemental Plan check only for Delta-2 under existing permit 16041-10000-26794.Add new light fixtures, relocate fixtures, and remove some fixtures.<<<PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR TENANT H2. SCOPE INCLUDES FOUR NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 2022 SQ. FT. b#16016-40000-17632>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38827	17041-20000-14143	9674 N SALOMA AVE	91343	7	201B149   496	2650009009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.24649	-118.45751	PV1.  Install 6.5 kW roof mounted grid tied PV system.  (26) modules with (13) APS YC500I microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38828	14041-10000-33815	1005 E 51ST ST	90011	9	111A209   366	5108015028	RD1.5-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	33.99676	-118.258	INSTALL 5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(20) MODULES: YINGLY YL255P-29B(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38829	16041-20001-07499	20334 W CHASE ST	91306	3	192B113   215	2781023001	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	PIN	34.22441031	-118.57682679	Expedited plan check.Plan check for the addition of a PV1 roof-mounted PV 3 kWac system onto an existing 9 kWac PV system, for a total system size of 12 kWac. Addition consists of (1) inverter, (8) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38830	15041-20000-34646	300 S GRAND AVE level 8	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	TI on the 8th level of a high rise build. Install new lighting fixtures and control, new panel and power <400A. PC for energy only. Total area: 20,723 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38831	16041-20000-30708	1234 W 7TH ST	90017	1	130-5A207 158	5143009003	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Issued	10/17/2016 12:00:00 AM	ADDRESS	34.05185	-118.26696	Plan check for roof-mounted solar array on commercial building. 20kW ungrounded system (10+10).(80) 340W pv modules. Interconnecte with 1200A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38832	15041-20001-00711	6036 N RHODES AVE	91606	2	177B165   589	2333014019	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	02/03/2015 12:00:00 AM	ADDRESS	34.18059	-118.40289	PV1 SFD. TOTAL SYSTEM SIZE 8.8KW AC USING 2 TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. TOTAL OF 30 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38833	18041-20000-14613	6442 N WHITAKER AVE	91406	6	180B137   586	2231002012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Issued	05/02/2018 12:00:00 AM	ADDRESS	34.18798	-118.49807	Plan check for roof mounted system solar PV system with battery back up 7.6kW with 31 modules and 1 inverter(7.6kW), 9.8kW DC battery ratting. Center fed system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38834	15041-20001-23640	8022 W OKEAN TER	90046	4	156B173   343	5570019026	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.12364	-118.37205	Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 20 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38835	16041-10000-40351	1716 N HIGHLAND AVE	90028	13	148-5A185 102	5547011004	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Issued	11/21/2016 12:00:00 AM	ADDRESS	34.10217	-118.3385	TITLE 24 PLAN CHECK.  T.I. & CHANGE OF USE FROM RETAIL TO TAKE-OUT RESTAURANT.  RELOCATE 200 AMP PANEL.  TOTAL AREA = 1,265 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38836	14041-10000-09797	11281 W HUSTON ST	91601	2	168B173   101	2353016016	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			04/14/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.16001	-118.37716	NEW FA  FOR 8 UNIT APT. 3 story R-2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38837	13041-10001-06781	1010 N HIGHLAND AVE	90038	4	144B185   909	5532027013	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.08928	-118.33841	MODIFICATION TO APPROVED SET OF PLANS UNDER PLAN CHECK NUMBER 13041-10000-06781. P1 AND S2 (OUTDOOR LIGHTING) LUMINAIRES WERE ADDED. DELTA 1 CHANGES CLOUDED.****************************************************13041-10000-06781 DESCRIPTION: T24 FOR EXISTING OFFICE SPACE AND WAREHOUSE AREA. SQRFT 7476. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38838	11041-10000-12758	10285 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/05/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of 1 elevator unit in Communication center Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38839	18041-20000-49107	2574 S AMHERST AVE pv1	90064	11	120B149   444	4257022040	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.02493	-118.44772	pv1install roof mounted pv system sized 3.7KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38840	16041-10000-15710	3627 S VETERAN AVE	90034	5	117B161   367	4252018006	RD2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.01872	-118.41523	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. 18 MODULES (SILEVO-U280) AND 3.6KW INVERTER(PVI-3.6-OUTD-US). TOTAL SIZE 3.6KW(AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38841	15041-10000-17002	3255 W PICO BLVD	90019	10	129B189   983	5081027015	C4-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.04732	-118.31381	TI - 24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 10824.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38842	13041-10001-30879	3037 N ARROWHEAD DR	90068	4	156B185    85	5577035011	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.12419	-118.32767	Expedited RSES plan check per applicant request.(((PV1, Install 10 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Fronius IG Plus V 7.5. 40 modules Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38843	16041-10000-20826	218 E 41ST PL	90011	9	114A205    69	5113033008	R2-1	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.00806	-118.27089	Install new  3.97 kw dc roof-mounted solar PV system to the existing system, (11) modules: SUNPOWER SPR-327NE-WHT-D(1) inverter: SMA AMERICA SB3000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38844	10041-20000-24888	555 W 5TH ST Garage-Level	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	02/07/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I. to existing high rise building.  Install general/emergency lighting in mailing area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38845	15041-20002-40370	7631 W BECKETT ST	91042	7	204A197   283	2558035021	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2016 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.25381	-118.299	01/27/2016 Changes to an approved set of plans. Inverter has increased from 5 kWac to 6 kWac. *****Previous Work Description*****PV1.  Install 5.16 kW roof-mounted, utility-interactive PV system.  (21) Silvantis F-Series 270W w/ (1) SolarEdge SE5000A-US transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38846	14041-20000-15775	20424 W VIA MANTUA	91326	12	219B109   321	2701060001	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.29979	-118.57912	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.8KW INTERCONNECTED WITH MAIN PANEL.(38) MODULES HYUNDAI HIS-S260MG(2) SUNNYBOY TRANSFORMERLESS INVERTERS 6000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38847	19041-10000-28521	450 S WESTERN AVE #315	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.06562	-118.30887	EXISTING RESTAURANT TENANT IMPROVEMENT TO BUILD OUT NEW RESTROOMS AND KITCHEN AREA FOR NEW TEA HOUSE (1600 SF)PLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38848	16041-10000-07551	5317 E YORK BLVD	90042	14	156A227   382	5478003014	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			Reviewed by Supervisor	03/24/2016 12:00:00 AM	ADDRESS	34.12031	-118.19996	CHANGE OF USE FROM AUTO BODY REPAIR TO RESTAURANT/RETAIL (CORE AND SHELL). 600 A service. Total area 6,486 sq.ft (indoor) + 557 sq.ft (outdoor dining area).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38849	18041-10000-15539	5461 W JEFFERSON BLVD	90016	10	120B177   474	5048017040	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			Reviewed by Supervisor	05/25/2018 12:00:00 AM	ADDRESS	34.02617	-118.36558	REPLACING A DAMAGED 600 AMP SERVICE EQUIPMENT WITH A NEW ONE AND RECONNECTING TO EXISTING LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38850	15041-10000-38099	6417 W SELMA AVE	90028	13	148-5A187 302	5546007022	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Closed	01/04/2017 12:00:00 AM	ADDRESS	34.09988	-118.33008	New fire alarm system to a New 10 story Hotel - Dream Hollywood.  350 fire alarm devices and 1 fire alarm control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38851	15041-20000-42584	22137 W STRATHERN ST	91304	3	189B101   240	2012004025	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.2157	-118.6096	Plan check for PV roof monted system. System size: 6.0kWac with 29 modules and 1 inverter(6.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38852	13041-20000-18931	600 S SAN VICENTE BLVD	90048	5	135B173   644	5510022043	CR-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.06586	-118.3728	NEW SERVICE, BOARDS AND NEW CIRCUIT WIRING.  PLAN CHECK FOR POWER AND ENERGY. FOR USE AS MEDICAL OFFICE/ OUT PATIENT FACILITY. XRAY MACHINE.  Clinic is State Licensed per Engineer, Requires OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38853	13041-10000-36325	6075 N VAN NUYS BLVD	91411	6	177A151    71	2241027003	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	PIN	34.18081008	-118.44909085	PLAN CHECK FOR POWER ONLY. TI. UPGRADING OLD 400 AMP SERVICE WITH NEW 600 AMP SERVICE. ADDING 4 NEW PANELS. RETAIL STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38854	12041-10000-00793	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Info Complete	01/12/2012 12:00:00 AM	ADDRESS	34.05956	-118.41375	Titel 24 only, TI office space no change in occupancy, suite 2060	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38855	19041-10000-40016	23331 S MALTBY PL	90710	15	042B193   114	7438003003	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Issued	10/03/2019 12:00:00 AM	ADDRESS	33.81368	-118.30489	PV1. PLAN CHECK FOR A NEW ROOFTOP SOLAR SYSTEM CONSIST OF 18 MODULES ( Q-CELL 335W) , OPTIMIZERS (P370) AND 1 CENTRAL INVERTER (SE5000H-US). SYSTEM SIZE IS 6.03 KWDC AND 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38856	11041-20001-18777	12199 W VENTURA BLVD	91604	2	162B165    60	2367017010	C2-1L, P-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM			PC Approved	01/25/2012 12:00:00 AM	ADDRESS	34.14344	-118.39842		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38857	17041-10002-22110	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	Changes to an approved set of plans. All changes are clouded under delta 9,10, & 11. Changes include revising lighinging floor plans showing dual circuits for exit signs, revising panel schedules, and revising single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38858	15041-20000-22455	725 S FIGUEROA ST 34th Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only. Project site is the 34th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 21,795 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38859	19041-10000-31906												Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38860	18041-10000-11448	1934-1936 N DRACENA DR	90027	4	150B197   696	5590013007	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.10638	-118.29	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.22KWdc / 5.0KWac. PV MODULES ARE ON TWO DIFFERENT SINGLE FAMILY HOMES FEEDING INTO ONE METER.(18)MODULES-S-ENERGY SN290M-10(18)OPTMIZERS-SOLAREDGE P320(1)INVERTERS-SOLAREDGE SE5000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38861	17041-20001-42726	7920 N MARQUAND AVE	91304	12	189B089   209	2020029049	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	12/14/2017 12:00:00 AM	ADDRESS	34.21397	-118.64831	expeditepv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38862	16041-10000-01363	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	FULL PLAN CHECK FOR TENANT IMPROVEMENT ON B, A, AND GROUND LEVEL COMMON AREAS; SCOPE INCLUDES ELECTRICAL WORK WITH NEW EQUIPMENT AND LIGHTING FROM A-LEVEL BASEMENT THRU GROUND FLOOR AT CORRIDOR/STAIR CASE/ELEVATOR AREAS;  CORE AND SHELL PERMIT WAS OBTAINED UNDER 14041-10000-09802 IN CONJUNCTION WITH APPROVED PLANS STAMPED BY PREVIOUS ENGINEER HIRED FOR PROJECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38863	11041-20000-15464	1458 S SAN PEDRO ST #301	90021	9	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	11/18/2011 12:00:00 AM	PIN	34.03045627	-118.25434986	Plan check power and energy for retail store. First time tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38864	12041-10000-04777	9301 N TAMPA AVE # 59A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T.I. FOR COSMETIC SHOP SUITE #59A IN AN EXISTING SHOPPING MALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38865	17041-10000-15367	1015 W D ST BLDG 12	90744	15	030B201   821	7417012907	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM				PC FOR FIRE ALARM FOR AN APARTMENT BUILDING. TOTAL DEVISE COUNT2 PANELS 39 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38866	11041-20000-11675	1423 N ORIOLE DR Main House	90069	5	147B169   711	5560006015	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Expired	08/01/2013 12:00:00 AM	ADDRESS	34.09755	-118.38834	Plan check for new single family dwelling with 800A service and power supplying guest house on separate application #11041-20000-11676.  (Plan check 1 of 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38867	10041-30000-07374	6200 N CANOGA AVE #100	91367	3	177B105   127	2149001035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	05/27/2010 12:00:00 AM	ADDRESS	34.1833	-118.59719	T.I.  WITHIN EX OFFICE SUITE W/ EMPLOYEE TRAINING ROOM - 5,140SF. Replacing existing light fixtures small portion of the highlighted office area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38868	15041-20001-01301	14511 W DAUBERT ST	91345	7	207B149    96	2615027019	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	34.26716	-118.44875	CHANGES TO APPROVED SET OF PLANS. CHANGE IN LOCATION OF AC DISCONNECT. RESTAMP NEW SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38869	19041-20000-08129	7200 W HOLLYWOOD BLVD	90046	4	147B181   173	5548009010	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.10149	-118.347	service upgrade to an existing apartment buiding 800 amp service reconnecting to existing panels.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38870	13041-10000-30237	14103 W VENTURA BLVD	91423	4	165B153   401	2265020021	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.1497	-118.44021	REMOVING (6) EXISTING HID FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES.TOTAL AREA TO BE 1482 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38871	17041-10000-15339	10250 W SANTA MONICA BLVD #1830	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for First Time Tenant ""Rodd & Gunn"" Ste. #1830.  Total area: 1800 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38872	14041-20000-10224	620 W USC MC CARTHY WAY	90089	9	118-5A201   5	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM			PC Info Complete	02/04/2015 12:00:00 AM	ADDRESS	34.02053	-118.28156	Electrical service and distribution equipment replacement in existing 3-story USC parking structure.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38873	19041-10000-44420	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	02/05/2021 12:00:00 AM	ADDRESS	34.09822	-118.31812	FULL PC FOR POWER AND ENERGY UNDER PHASE THREE, SCOPE OF WORK IS A TI(FIRST TIME), SCOPE OF WORK INCLUDES VARIOUS SUBPANELS AND ELECTRICAL EQUIPMENT CONNECRTED TO AN ELECTRICAL SYSTEM THAT WAS APPROVED UNDER 16041-10K-43434. TOTAL AFFECTED AREA IS 139,743 sqft.**Reference Only: Plan Checker to verify the submittal fees.Building Permit# 19016-10000-23585**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38874	19041-20001-47302	10320 N KEY WEST AVE	91326	12	204B117   128	2728009030	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.25804	-118.55343	Revision to approved plans.  Removal of PV performance meter as per LADWP standards.$0 plan check fee per State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38875	17041-20000-22109	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLANCHECK FOR T24 ENERGY. LOADING DOCK MECHANICAL ROOM.  135 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38876	11041-20000-00778	18325 W VANOWEN ST	91335	3	183B125   829	2125012009	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Apartment			01/13/2011 12:00:00 AM	03/29/2011 12:00:00 AM		Permit Finaled	06/09/2011 12:00:00 AM	ADDRESS	34.19401	-118.5325	Plan check roof mounted 98.67KW photovoltaic system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38877	14041-20000-16730	10895 W OLINDA ST	91352	6	192B173    21	2408011008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.22661	-118.36803	PV1.  Install 5.0 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38878	13041-20003-13571	12059 W VENTURA PL	91604	2	165B165  1242	2368002010	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.14469	-118.39458	Delta-5 revisions to approved set of plans.  Additonal switchboard sections per as-built design.  ((changes to approved set of plans. change includes relocation of items and addition of some items. ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38879	19041-10001-07684	12989 W BRANFORD ST	91331	7	198B161   259	2626018001	RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.23939	-118.41564	New roof-mounted solar 6.65KW PV system with 19 PV panels on a Sinle Family Home.Plan Check Only. Permit was issued under: 19041-90000-07684	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38880	16041-10002-20552	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	34.05715	-118.41482	PC for changes to approved set for methane mitigation system. Changing membrane slab configuration on B4 and B3 levels. Reducing number of sensors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38881	19041-20000-42149	4652 N CONCHITA WAY	91356	3	168B117   385	2178013024	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.1555	-118.5592	Plan check for PV roof mounted system and energy storage system, PV system size: 6.84KW DC, 6.10KW AC CEC with with 19 AC Modules and 1 Tesla Power Wall 2.0, 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38882	19041-20001-23077	1016-1020 N WHITE KNOLL DR	90012	1	136-5A213  19	5406022028	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM			PC Approved	11/04/2019 12:00:00 AM	ADDRESS	34.06996	-118.24646	Revisions to approved set of plans.  Change of conduit size on SLD.  (((1200A 240/120V 1ph-3w service for small lot subdivision.  Plan check for power.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38883	12041-10000-24143	10768 W BELLAGIO ROAD	90077	5	138B149     6	4362010001	A1-1XL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.0802	-118.45043	New 300 kw generator to backup 1600 A service for Bel Air country club. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38884	18041-20000-19184	10618 N COLLETT AVE	91344	12	207B141   510	2668007002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.26345	-118.48349	PV1.  Install 17.875 kW roof mounted grid tied PV system.  (55) modules with (2) 7.6 kW rated string inverter.INSPECTION FEE IS 0 $ DUE TO SB-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38885	15041-20000-36342	20458 W RUNNYMEDE ST	91306	3	186B109   571	2114009035	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.20579	-118.57927	PV1, roof top mounted solar panel, 4.56 kW (16) modules: SW285 MOno(1) inverter: SE5000A-USPower optimizer is used.Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38886	19041-10000-19745	10750 W MAGNOLIA BLVD	91601	2	171B177   695	2419009002	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1255.01	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Issued	05/24/2019 12:00:00 AM	ADDRESS	34.16472	-118.36539	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38887	14041-10000-29733	11766 W WILSHIRE BLVD SUITE 1200	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.04804	-118.46227	Title 24 plan check only.  Total area = 14,781 sq. ft.T.I. to existing highrise office space.  Installation of lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38888	15041-10000-38085	1050 W PACIFIC COAST HWY 1ST FLR	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	33.79072	-118.29449	PC FOR T24 ENERGY ONLY. LIGHTING ALTERATIONS GREATER THAN 40 LUMINAIRES. NO OTHER WORK BEING DONE. WORK DONE ON FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38889	17041-20000-18229	17638 W RAYMER ST	91325	12	192B129    51	2787029005	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.22646	-118.51894	Plan check for solar pv sysetm, roof-mounted on SFD.10kW ungrounded sysetm. (40) 330W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38890	17041-20000-28036	8541 N LANKERSHIM BLVD	91352	6	192B169   256	2633030018	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1218.02	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.22499	-118.38797	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38891	14041-10000-35115	16747 W VENTURA BLVD	91436	5	168B137   197	2259011030	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.15883	-118.49843	T24 only. remove HID light fixtures and replace with new LED fixtures, total area 2270 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38892	18041-20000-11233	109 N AVENUE 56	90042	1	151-5A229 273	5468033015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.10933	-118.19434	Change of use to office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38893	17041-20000-07886	4320 N VANTAGE AVE	91604	2	165B165   571	2367004028	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.1493	-118.39743	"""0$ permit fees due to senate bill 1222""pv1install roof mounted pv system sized 11kw interconnected with msp."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38894	11041-20000-00535	2750 W RIVERSIDE DR	90039	4	151-5A207 105	5438024021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	03/29/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	34.10876	-118.26115	Plan check new roof mounted 54.7KW Photovoltaic System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38895	11041-20002-04633	2321 S ABBOT KINNEY BLVD #102	90291	11	106-5A147  10	4229012030	C2-1	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM			PC Approved	04/06/2011 12:00:00 AM	ADDRESS	33.98774	-118.45895	PLAN CHECK ONLY. T24 ENERGY/EMERGENCY LIGHTING FOR TI. EXISTING PERMIT FOR WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38896	16041-20000-14142	163 E 111TH PL	90061	8	087A205    37	6073017030	R2-1	South Los Angeles	Southeast Los Angeles			2411.10	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	33.93404	-118.27161	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38897	14041-20000-08544	8448 N VARIEL AVE	91304	3	192B105   328	2779045030	R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.22361	-118.59275	PV1 4KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(16)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38898	17041-10001-40403	741 E 43RD ST	90011	9	114A207   268	5115008016	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.00582	-118.2627	Plan check for a lost PV plan.(((pc FOR NEW ROOFMOUNTED PV ON SINGLE FAMILY. SYSTEM SIZE IS 3.8KWaC/ 3.5KWdcsCOPE INCLUDES 13 MODULES, CENTRAL INVERTER WITH OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38899	15041-10001-10458	2511 W 3RD ST	90057	13	135A203    96	5155033018	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.06525	-118.27685	TI TO AN EXISTING BUILDING, DIALYSIS CLINIC OSHPD-3. PC FOR POWER. I2.1 OCCUPANCY EXEMPT FROM ENERGY.     (     design changed   .   more than 70 %  m.z   11-23-15)    .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38900	16041-20000-32955	1932-1936 S PONTIUS AVE	90025	5	126B153   339	4323025005	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.04342	-118.44132	TI to (E) warehouse space.  New 400 A 240V 3 phase service.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38901	13041-10000-34908	11818 N GLENOAKS BLVD	91340	7	216B157    78	2524001047	M2-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.28468	-118.42301	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38902	19041-10000-24820	4170 S LEIMERT BLVD	90008	10	114B189   739	5023006020	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Apartment			08/05/2019 12:00:00 AM			PC Info Complete	10/13/2023 12:00:00 AM	ADDRESS	34.00889	-118.32504	FULL PLAN CHECK FOR A NEW CONSTRUCTION OF 4 UNIT 4 STORY APARTMENT ABOVE GRADE, LEVEL PARKING. SCOPE INCLUDES A NEW 600-AMP PULL SECTION AND 6-PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38903	14041-10000-25769	3501 N MONTEREY ROAD	90032	14	142-5A231  47	5305005024	[Q]C1-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.08644	-118.18767	Title 24 plan check only.  Total area = 738 sq. ft.T.I. to existing restaraunt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38904	16041-10000-44019	8646 N SEPULVEDA BLVD	91343	6	195B145   556	2654021131	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.22778	-118.46747	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 102000.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38905	14041-20000-34421	7100 W SUNSET BLVD	90046	4	147B181   696	5548017400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.09774	-118.34439	PLANCHECK FOR POWER AND ENERGY. NEW RETAIL BUILDING. 1 STORY. [ TAP ON UGPS DWP JURISDICTION PER APPLICANT, {CONDITIONAL APPROVAL  PER DWP UTILITY SERVICE REPORT FOR ISC LESS THAN 42,000}).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38906	12041-10000-02719	211 S AVENUE 20	90031	1	138A221   207	5447024005	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.07213	-118.22001	NEW 2-STORY PRIVATE SCHOOL. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38907	18041-20000-07145	5901 W CENTURY BLVD # 1035	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	33.94572	-118.38685	Plan check for Title 24 only. Project site is an existing suite in a commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 1,683 sq. ft.Note: Building application has been generated under 18016-10000-00674	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38908	19041-20000-42382	11952 MIRABEL WAY	91326	12	216B109   180	2701081029	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	PIN	34.29032742	-118.58191508	Plan check for PV roof mounted system, PV system size: 5.25KW with 15 AC Modules, new sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38909	18041-10000-23754	321 N FIGUEROA ST Ste. 321	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	33.77256	-118.27884	Plan check for T24 only, TI on (E) warehouse/office/restroom area. Total area under the SOW: 6,750 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38910	17041-10001-03677	5713 N FIGUEROA ST	90042	1	151-5A229 174	5492001014	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			PC Approved	08/18/2017 12:00:00 AM	ADDRESS	34.1099	-118.19254	PC FOR TO REFLECT FIELD CHANGES TO LUMINAIRE INSTALLED. SCOPE INCLUDES NEW TYPE OF LUMINAIRE AND TITLE 24 REVISION. THIS IS PLAN CHECK ONLY!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38911	17041-10001-35423			9	108B201  1300	5101040009	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	PIN	33.98951569	-118.279735	Expedite per applicant request.(((PV2 84KW AC  roof mounted system with (324) module, (3) inverter, (3) transformer, and (3) sub panels.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38912	11041-10000-06766	22420 W DEL VALLE ST	91364	3	171B101   174	2040034022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1372.01	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM			PC Approved	04/05/2011 12:00:00 AM	ADDRESS	34.16821	-118.61507	NEW RESTAURANT.  TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38913	11041-20000-20227	1647 N SILVER LAKE BLVD	90026	4	144A205   223	5425017001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.08927	-118.26881	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38914	17041-10001-31379	16744 W HALSTED ST	91343	12	201B137   916	2686022002	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.24442	-118.49739	OFF HOUR PLAN CHECK FEESORIGINAL PLAN CHECK 17041-10000-31379PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 54 AC MODULES(SUNPOWER SPR-X21-345-C-AC). SYSTEM SIZE 17.28KVA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38915	15041-20000-07959	18725 1/2 W VENTURA BLVD	91356	3	174B121   512	2160002050	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.17121	-118.54158	Plan check for T-24 only (physical treament T.I.). total area: 1360 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38916	19041-20000-01580	1636 N FULLER AVE 1-15	90046	4	147B181   239	5548009004	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.10099	-118.34883	plan check for em lighting to an existing apartment building.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38917	12041-20000-09584	15729 W SEPTO ST	91343	12	201B141    43	2661026006	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.25114	-118.47492	New 5.13 Kdc Photovoltaic System with roof mounted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38918	12041-10000-15710	5651 N SEPULVEDA BLVD	91411	2	174B145   358	2243002014	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.17358	-118.46646	Plan check for fire alarm system. 1 new panel and 178 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38919	19041-20000-12692	17531 W WEDDINGTON ST pv1	91316	5	171B129   102	2257004059	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.16687	-118.51544	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38920	16041-10000-44869	133 E HURRICANE ST	90292	11	103-5A147 259	4225008904	RW2-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Info Complete	10/24/2017 12:00:00 AM	ADDRESS	33.97603	-118.46134	FULL PC FOR POWER AND ENERGY FOR A NEW PUMP STATION. SCOPE INCLUDES NEW DISTRIBUTION BOARDS, NEW PANELS, NEW TRANSFORMERS, GENERATORS, NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2720 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38921	15041-20000-26215	11064 N CHIMINEAS AVE	91326	12	210B125   394	2715013019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Expired	09/06/2017 12:00:00 AM	ADDRESS	34.2717	-118.52846	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 4.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38922	10041-20000-03682	2700 S FIGUEROA ST TEMP	90007	9	121-5A203  98	5123018031	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/17/2010 12:00:00 AM		Permit Closed	10/22/2010 12:00:00 AM	ADDRESS	34.02708	-118.27647	600 A TEMP. POWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38923	15041-10000-10852	12100 W WILSHIRE BLVD	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			PC Approved	04/13/2015 12:00:00 AM	ADDRESS	34.0438	-118.46755	TI TO AN EXISTING HIGH RISE BUILDING ADDING LIGHTING TO RESTROOM LIGHTING TO THE 8TH, 11TH, 18TH FLOORS. PLAN CHECK FOR ENERY ONLY. PERMIT FEES UNDER APPLICATION #: 15041-90000-10852	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38924	16041-10000-28993	660 S FIGUEROA ST SUITE 1790	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Expired	10/03/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	TITLE 24 FOR (TI) FOR AN EXISTING (COMMERCIAL)BUILDING. NEW OFFICE SPACES BEING ADDED TO THE 17TH FLOOR - SUITE(1790)TOTAL SQ. FT. (1474)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38925	18041-30000-11085	1900 S AVENUE OF THE STARS 18th Floor-Rest Room	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for Title 24 only in existing space corridor and public bathroom new lighting T.I. Total area: 1620 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38926	13041-10000-24043	920 W DOWNEY WAY 2nd floor-B-201	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.02063	-118.28879	permit to be pulled at EPC counter only. PC for energy only. emergency lighting. bigler hall of engineering. 2nd floor.LABORATORY REMODEL + MECHANICAL EQUIPMENT ON ROOF. 2,539 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38927	19041-10000-28320	700 S FLOWER ST 14TH FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC ENERGY ONLY FOR TI, INTERIOR RENOVATIONS - NEW NON BEARING PARTITIONS, MILLWORK, CEILING, LIGHTING AND FINISHES. AREA OF WORK 13,476SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38928	19041-10000-43945	1520 N GILCREST DR	90210	4	147B165   308	4352009049	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	34.09863	-118.40237	POWER PLAN CHECK FOR THE INSTALATION OF A NEW OPTIONAL STANDBY 325 KVA GENERATOR. SYSTEM INCLUDES A 300KVA STEP DOWN TRANSFORMER, 800A ATS, AND NEW 800 DISTRIBUTION BOARD TO FEED NEW AND EXITING LOADS. {E} 800A SERVISE.    *SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38929	11041-20000-07849	161 E 36TH ST BLDG B	90011	9	117A205    47	5120009017	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Apartment			04/19/2011 12:00:00 AM			PC Approved	04/19/2011 12:00:00 AM	ADDRESS	34.01629	-118.27159	energy plan check community room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38930	16041-10000-20470	1025 E ADAMS BLVD	90011	9	118-5A209 348	5131026029	C2-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.01916	-118.25542	Full PC, Interior tenant improvement of an existing commercial retail space. New connected load > 400A. Total area: 17,914 sq.ftB# 16016-40000-12645	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38931	11041-10000-08112	3286 W SLAUSON AVE	90043	8	105B185  1434	4005005032	P-1, [Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	33.98868	-118.33002	First time tenant, change of use from retail to restaurant. power, lighthing, title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38932	12041-10000-11976	4610 S MAIN ST	90011	9	112-5A205 326	5109002027	C2-1VL	South Los Angeles	Southeast Los Angeles			2285.00, 2319.00	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	PIN	34.00121161	-118.27359852	PLAN CHECK NEW INSTALLATION OF FIRE ALARM SYSTEM FOR 2 STORY CHARTER HIGH SCHOOL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38933	19041-30000-19232	2000 S AVENUE OF THE STARS 6th Floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for Title 24 only. Project site is a part of the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 523 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38934	19041-20000-08377	5203 N LANKERSHIM BLVD	91601	2	171B173   588	2350017058	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.16507	-118.37498	Plan check for Title 24 only. Project site is a new single-story restaurant. Total lighting area = 4,034 sq. ft.Note: Building application has been generated under 16010-10000-06131	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38935	17041-10000-03899	18405 W SUPERIOR ST	91325	12	201B125   264	2764005024	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.2465	-118.53496	Plan check for Title 24 only in existing space, remove outdoor HID lighting fixture and replace with new LED  lighting fixtures. Total area: 110,100 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
38936	14041-20001-02288	5226 N BECKFORD AVE	91356	3	171B117   239	2163009010	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	ADDRESS	34.16583	-118.55162	((((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38937	15041-10000-18337	14106 W GRUEN ST	91331	6	201B153   783	2644008008	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.24529	-118.44028	Standard plan PV1 6KW roof-mounted system with (30) Kyocera KU2656 modules, (2) ABB PVI -3.0 inverters interconnecting through a load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38938	14041-10000-13083	6720 N ROYER AVE	91307	12	180B097    92	2038015001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.19259	-118.62826	PV1 3.675KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {SUNNY BOY 3000TL-US-22}]. [(15)modules: {Trina {TSM-245PC05.18}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38939	15041-10001-35457	8001 N VENTURA CANYON AVE	91402	6	189B157   306	2213019040	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.21649	-118.42885	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE TO SERVICE EQUIPMENT LAY OUT. CHANGE INCLUDES MAKING PV READY. UPDATED AIC RATINGS ON PLANS. ALL CHANGES CLOUDED DELTA 1 REVISION. THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38940	12041-10000-17951	301 N LARCHMONT BLVD	90004	4	138B189   420	5523020039	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.07648	-118.32385	NEW RESTAURANT -CHIPOTLE-COMPLETE PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38941	19041-20000-34226	4309 N IRVINE AVE	91604	2	165B169   570	2365024017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.14766	-118.38569	PV1.  Install 9.45 kW roof mounted and grid tied PV system and 13.5 kWh energy storage system.  (30) modules with 7.6 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38942	17041-10000-40160	18081 W VENTURA BLVD	91316	5	171B125   374	2162005080	C2-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.16551	-118.52691	Remove HID fixtures and replace with new LED fixtures  T-24 only.5525 SQ.FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38943	18041-10000-44825	1002 W CHILDS WAY 100, 105,-120	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.02201	-118.28947	T-24, PC FOR ENERGY ONLY. INTERIOR TI FOR EXISTING OFFICES IN BASEMENT LEVEL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 637 SQ. FT. B#18016-10000-35232	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38944	17041-20002-05773	10404 N SEPULVEDA BLVD BLDG 2	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	PIN	34.25931857	-118.46630746	SUPPLEMENTAL PLANCHECK ONLY FOR POWER DUE TO FIRST TIME TENANT.  PERMIT UNDER MASTER APPLICATION 17041-20000-05773.*****Previous Work Description*****TENANT IMPROVMENT TO RETAIL SPACE (T-MOBILE).  PLAN CHECK FOR ENERGY.Note: Building permit has been pulled under 17016-20000-03987 with an address correction under 17016-20001-03987.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38945	15041-20000-04974	1660 N ROSCOMARE ROAD	90077	5	147B145    80	4377016016	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Expired	04/05/2017 12:00:00 AM	ADDRESS	34.10034	-118.46273	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.8KW INTERCONNECTED WITH MSP.(45) LG MONOX 300WATTS MODULES(45) ENPHASE M250 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38946	13041-20001-32708	9020 N RESEDA BLVD BLDG A	91324	12	195B125    51	2769001028	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.2346	-118.53587	Plan check for modifications to approved set. Removed two tenant panels - reflect changes on SLD, floor plan (updated home-runs), and panel schedules.[[[INSTALLING (2) NEW SERVICES TO (2) BUILDINGS ('A' AND 'B'). BUILDING 'A' IS NEW, AND BUILDING 'B' IS FOR A REMODEL TO EXISTING BUILDING. THIS APPLICATION IS FOR BUILDING 'A'. ADDING NEW 800A SERVICE.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38947	18041-10002-18152	2308 S CASTLE HEIGHTS AVE	90034	5	126B165   279	4309008003	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM			PC Approved	05/21/2018 12:00:00 AM	ADDRESS	34.04345	-118.39761	**ESS**New rooftop solar system and storage battery on SFD, (11) modules with (11) power optimizers, (1) 5.2 kW inverter, (1) 13.5 kWh ESS, (1) 125A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38948	18041-10000-22462	3771 N WINFORD DR	91356	3	162B117   378	2177045018	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.13693	-118.55398	INSTALL A 18.9 (AC) KW, WITH 54 AC SOLAR MODULES SPR-X21-350-BLK-D-AC,  AND (1) 125A LOAD CENTER ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38949	16041-10000-10309	1231 W 252ND ST	90710	15	036B197   230	7413007021	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	33.79584	-118.29863	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (22)MODULES-HANWHA Q-CELLS: Q.PRO BRF-G4 260(1)INVERTER-SOLAREDGE  TECHNOLOGIES: SE5000 (240V)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38950	19041-10001-07236	5965 S ST ANDREWS PL Tent	90047	8	105B193   333	6001013906	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Apartment			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	33.98626	-118.3116	CHANGES TO APPROVED SET OF PLANS. ALL CHANGES TO REFLECT AS BUILT. CHANGES INCLUDE REVISING LIGHTING FLOOR PLANS,  REVISING PANEL SCHEDULES FOR WATER HEATER, AND HEAT LAMPS.  NOTE: PERMIT FEES ARE COVERED UNDER MASTER APPLICATION.FULL PC FOR A NEW HOMELESS SHELTER(1 OF 2).  SCOPE INCLUDES A NEW 600A 480/277 3 PHASE 4 WIRE FOR A TENT STRUCTURE. NEW SITE LIGHTING AND CIRCUITS.  B#19010-10000-00856	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38951	12041-10000-02200	17220 W OSBORNE ST	91325	12	195B133   139	2690003015	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2012 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.2333	-118.50945	14.4 kw PV  for a single family. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38952	17041-10000-13554	900 N ALAMEDA ST 4th FLR	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	4TH FLOOR BUILDING OUT PHASE 2. PROJECT IS FOR NEW DISTRIBUTION SYSTEM TO SUPPLY A DATA CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38953	14041-20000-08554	20470 W NASHVILLE ST	91311	12	210B109   161	2707026019	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Expired	05/19/2016 12:00:00 AM	ADDRESS	34.26998	-118.57907	PV1 10KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(2) inverters: {PVI-3.6-OUTD-US , PVI-3.6-OUTD-US }]. [(40)modules: {Canadian Solar {CS6P 250P}}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38954	16041-20000-14494	21418 W OSBORNE ST	91304	3	195B105    68	2779047004	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.2335	-118.59828	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600-amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38955	17041-10002-04622	20059 W RINALDI ST BLDG C1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			PC Approved	05/07/2018 12:00:00 AM	ADDRESS	34.2756	-118.57118	PLANCHECK ONLY. DELTA 4 CHANGES TO APPROVED PLANSSCOPE INCLUDES RELOCATION OF MAIN ELECTRICAL ROOM AND REVISION TO EXTERIOR LIGHTS AND T-24 FORMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38956	19041-20000-52297	818 W 7TH ST #830	90017	14	129A209    60	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.04895	-118.25943	Plan check for Title 2 Energy only, new lighting. Total area: 5259 sq ft. B#19016-10000-30422	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38957	16041-10000-38733	450 S WESTERN AVE 3RD FLOOR	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.06562	-118.30887	PC FOR POWER AND ENERGY. FIRST TIME TENANT. FOOD COURT. (E) MAIN SWITCH GEAR IS 4000A.  TOTAL AREA 2373 SQ FT. B # 1601+6-70000-06230	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38958	15041-10001-01054	9301 N TAMPA AVE #134	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Supplemental application for changes to an approved set of plans. Changes are marked as Delta 1 and include a change to light fixtures and Title 24 Compliance Form calculations. *******Previous Work Description*********TENANT IMPROVMENT, INTERIOR NON BEARING PARTITIONS IN (E) RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38959	17041-10000-16572	1425 N CAHUENGA BLVD	90028	13	147A187   218	5546014054	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.09683	-118.32966	Title 24 plan check.  Remodel existing office.  New lighting and receptacles.  Subpanels to remain existing.  Total area = 2,470 sq. ft.       Building permit #16016-20000-27843	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38960	14041-20000-17389	6320 N CANOGA AVE suite 495	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check for energy only. New lighting (incl. emergency) on 4th floor of existing high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38961	15041-20000-21836	333 S HOPE ST 30th Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	TI to existing high rise commercial building (30th floor). Plan check for energy only. Adding new lighting including emergency. Total Sqft. 16, 091.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38962	11041-20000-03284	10201 W PICO BLVD 5 & 6	90035	5	129B161  1442	4315019012	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			02/18/2011 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Finaled	08/08/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	Install general/emergency lighting partial of 1st. and 2nd floors of building 6.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38963	17041-10000-37197	11025 N STRANWOOD AVE	91345	7	210B145   253	2664005019	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.27058	-118.46621	REPLACING OUTDOOR AND INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38964	10041-10000-16156	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Install general lighting in new restroom area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38965	18041-10000-36989	14416 W CHASE ST	91402	6	192B149   186	2638022048	[Q]C2-1-CDO, [Q]P-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.22464	-118.44689	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38966	11041-20000-01474	4950 W SANTA MONICA BLVD	90029	13	144B197   776	5538011016	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	34.09069	-118.29755	PLAN CHECK POWER AND ENERGY FOR PLACE OF ASSMEBLY (CHURCH). CONSOLIDATING TWO SERVICES TO NEW ONE 400A SERVICE AND NEW EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38967	14041-20000-05545	15024 W SAN JOSE ST	91345	7	207B145   690	2649023017	R1-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.26083	-118.45954	PV1 SINGLE FAMILY DWELLING USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 14 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38968	15041-20000-29390	9301 N SHOSHONE AVE	91325	12	198B129   214	2766020040	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.23982	-118.51791	PERMIT FEES $0.00 BY STATE SENATE BILL#1222Plan check for a PV1 roof-mounted PV system. System size is 16.4 kWac and consists of (2) inverters, (80) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38969	18041-10000-10362	734 S MAIN ST	90014	14	127-5A211 186	5145001001	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Issued	11/09/2018 12:00:00 AM	ADDRESS	34.04318	-118.25216	PC FOR TITLE 24 ENERGY ONLY. FOR EXISTING 4 STORY BUILDING WITH BASEMENT AND MEZZANINE; BASIC UPGRADE FOR LIFE SAFETY.TOTAL CONNECTD LOAD <400ASCOPE INCLUDES NEW PANLES, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 18454 SQ.FT.B#18016-10000-05811	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38970	10041-10000-15400	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	07/19/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI IN THE COURT YARD AND FOUNTAIN AREA, ON THE NORTH AND SOUTH SIDE OF THE BUILDING ON THE STREET LEVEL. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS FOR OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38971	16041-10000-27775	1906 W 3RD ST	90057	1	133-5A205  28	5154027029	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Closed	04/23/2024 12:00:00 AM	ADDRESS	34.06192	-118.27064	This is PC for power only. Replacing 136 subpanels for guestrooms in motel. (PC for TI24 was completed under seperate permit 16041-10002-17364 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38972	19041-10000-20967	1336 E 16TH ST	90021	14	121-5A211 370	5130015006	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.02559	-118.24771	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38973	16041-10000-36218	12100 W WILSHIRE BLVD fl. 3-5,16	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING CORRIDORS FOR FLOORS 3,4,5 & 16.  REPLACING OF LIGHT FIXTURES AND EGRESS SIGNAGE.  TOTAL AFFECTED AREA IS 3876 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38974	13041-10000-25902	13345 W CUMPSTON ST	91401	4	174B157   955	2344012015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.16961	-118.42407	PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 8.25kW. 33 TRINA TSM 250 MODULES. 1 FRONIUS IG PLUS 7.5 kW INVERTER. 2 STORY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38975	13041-10000-02356	10350 N RESEDA BLVD	91326	12	204B125    76	2731016006	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.25862	-118.53582	"Power and Energy plan check for a new single story McDonalds. 33,329sqrft. Panel ""Center Island"" is missing from the panel schedule."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38976	14041-20000-24875	7014 S HOOVER ST	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 2.0KW INTERCONNECTED WITH HOUSE PANEL.ENPHASE M250 MICROINVERTER.ZONING CLEARANCE UNDER THIS APPLICATION SHALL BE APPLICABLE FOR ALL SOLAR INSTALLATIONS UNDER THIS BUILDING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38977	19041-10000-24389	5000 N VAN NUYS BLVD #400	91403	4	171A151   223	2248008087	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM			PC Info Complete	06/25/2019 12:00:00 AM	ADDRESS	34.16138	-118.44849	PC for T24 only, scope of work is an office TI in suite 400, not a high rise. Total affected area is 9005 sqft. B#: 19016-10000-18569	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38978	16041-10000-39659	6228 S 8TH AVE	90043	8	105B189  1100	4007010006	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	33.98295	-118.32633	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.76KWdc / 3.8KWac.(17)MODULES-HANWHA Q-CELL Q PLUS-G4(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38979	18041-30001-11422	12820 W PANAMA ST	90066	11	105B157   395	4223008012	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Info Complete	07/31/2018 12:00:00 AM	ADDRESS	33.98477	-118.42659	This is additional plan check and permit to master# 18041-30000-11422. This plan is to add outdoor lighting to the scope of work. Total area: 2,665 sq.ft. Add (2) curcuits for these outdoor lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38980	13041-10000-24150	819 S FLOWER ST Basement	90017	9	129A207   199	5144021032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.04688	-118.26067	PLAN CHECK POWER AND ENERGY FOR RESTAURANT/WINE BAR IN EXISTING HOTEL LOCATED ON BASEMENT LEVEL. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM FROM ELECTRICAL PLANS HAVE BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38981	14041-10000-29651	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008023	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.05001	-118.25963	Power and energy plan check for Hotel interiors, mainly kitchens and guest room. reference plan check number E14LA02023. Energy plan check based on 2008 standard. note. fee provided by customer, plan check engineer need to verify the fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38982	13041-20001-29213	14333 W ADDISON ST 1-46	91423	4	171B153   727	2248008039	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			10/21/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.16135	-118.44556	((EXPEDITE FEES)))PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 15 KW AC USING 70 MODULES. USING 3 CENTRAL INVERTERS. WITH ISOLATION TRANSFORMER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38983	15041-10000-19300	4359 N COLDWATER CANYON AVE	91604	2	165B161   384	2375009015	[Q]C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.14997	-118.41395	REPLACE EXISTING LIGHTING UNDER ARCO CANOPY WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY. TOTAL HARDSCAPE AREA 17459.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38984	15041-20000-10490	807 N SEWARD ST	90038	4	141B185   216	5533024004	MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.08553	-118.33327	Plan check for Title 24 only. Project site is a parking lot and scope of work is the installation of 12' light pole. Total lighting area = 6,500 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38985	18041-20000-33422	20659 W BEECH CIR #325	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.29279	-118.58435	Plan check for PV roof mounted system, system size: 3.02kW  with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
38986	10041-20000-06178	5400 N BALBOA BLVD suite 111	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1390.00, 1397.01	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	PIN	34.16914714	-118.50029545	Plan check power and energy for medical office. Not check for OSPHD III	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38987	15041-10000-11702	11034 W SHERMAN WAY Ste B	91605	2	183B173   118	2319002024	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	PIN	34.20058405	-118.37194969	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38988	19041-20000-12043	1839 S MAIN ST	90015	14	123A207   104	5126029005	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Apartment			04/05/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Issued	06/27/2019 12:00:00 AM	ADDRESS	34.03137	-118.26461	Plan check for power only replace 600A meter section for existing 60 units multi-family building. Existing 1600A service, feeder and panel to unit to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38989	15041-10000-43362	1110 S GAYLEY AVE	90024	5	132B149   103	4363023027	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.05996	-118.44602	PC for energy only, Ti to an existing commercial building, change of use from retail to restaurant. Adding new lighting and power. Total Sq ft = 1464	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38990	19041-10000-29496	700 S FLOWER ST 15TH LR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR T24 ONLY. SCOPE OF WORK IS A TI IN AN EXISTING HIGHRISE, 15TH FLOOR TO BE EXACT. SCOPE OF WORK INCLUDES NEW LIGHTING,RECEPATCLES, AND CONTROLS. TOTAL AFFECTED AREA IS 17767SQFT. B#: 19016-10000-22423	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38991	15041-20001-32749	1622 W 7TH ST	90017	1	132A205   345	5142016009	C2-2	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	PIN	34.05412662	-118.27207044	expedite feespv2 commercial rooftop pv. total of 2 inverters and 54 modules. nonstandard plan. interconnected to existing service. may be multi meter bank 20 kw ac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38992	17041-20001-23000	1164 S ROBERTSON BLVD	90035	5	132B169   825	4332015022	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM			PC Approved	09/15/2017 12:00:00 AM	ADDRESS	34.05542	-118.38354	09/11/2017 CHANGES TO APPROVED T24 SET. CHANGES TO LIGHTING AND T24 TO MATCH SITE. SQFT 696*****Previous Work Description*****PC for T24 for new decorative lighting. Total affected area is 355 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38993	13041-20000-17104	17811 W TWILIGHT LANE	91316	5	165B129   255	2184037001	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02, 1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.14734	-118.52057	pv1 single family dwelling. using enphase microinverter. nonstandard plan. 11.28 kw. using 48 panels. 400A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
38994	11041-20000-25319	6555 W FOOTHILL BLVD	91042	2	201A203   106	2570019008	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.24594	-118.27468	Replace & relocate existing FACP & Power Supply installed by others	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38995	14041-10000-23778	16860 W BOSQUE DR	91436	5	165B133   219	2291003008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.14999	-118.50019	PV1 8.25KWdc. 240V. positive GND. NONstd. ???story. Roofmount. [(30) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(30)modules: {solarworld SunModule SW-275 mono}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38996	16041-20000-36812	10600 N SEPULVEDA BLVD	91345	7	207B145   458	2649011022	P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.26279	-118.46696	permit fee $0.00 by state senate bill no.1222Plan check for a PV2 roof-mounted PV system. System size is 54 kWac and consists of (5) inverters, (212) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
38997	18041-10000-35090	6708 W FOOTHILL BLVD	91042	7	201A203    61	2564010038	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.24706	-118.27842	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38998	16041-10000-18919	1900 S SANTA FE AVE	90021	14	120A217   132	5168005009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.02247	-118.22995	PC for T-24 only. Re,ove HID fixtures and replace with new LED fixtures. Total area: 4,480 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
38999	10041-20000-18369	5570 S LINCOLN BLVD	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	10/12/2010 12:00:00 AM	ADDRESS	33.97271	-118.43031	Plan check T-24 Energy for office TI. All existing circuits. Permit for (8) additional receptacles, new additional light fixtures, and tracking lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39000	17041-20000-34230	8999 N BALBOA BLVD	91325	12	195B133     8	2690006017	(Q)C2-1VL	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Issued	09/25/2017 12:00:00 AM	ADDRESS	34.23353	-118.50275	Install new LED fixtures on existing poles in (E) parking lot.  No new or altered circuits.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39001	09041-10001-18276	432 N FAIRFAX AVE	90036	5	141B177  1334	5527030021	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM			PC Approved	01/08/2010 12:00:00 AM	ADDRESS	34.07914	-118.36128	Plan check energy only for remodel of  existing restaurant.  Power was approved on the orignal application. Place of assembly.  New 400A electrical system. Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39002	15041-10000-19082	1055 N NORMANDIE AVE	90029	13	144B193   829	5537018006	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.09004	-118.30063	PC FOR ENERGY T24. REMODELING OF BASEMENT OF  A CHURCH AS DINNING AREA; SCOPE INCLUDES NEW PANELS, RECEPTACLES AND LIGHTING. TOTAL AREA 4090 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39003	13041-10000-28630	15818 W ARMINTA ST	91406	6	189B141   164	2206002032	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.21378	-118.47801	Remove HID light fixtures and replace w/ fluorescent fixtures.  Title 24 plan check only, permit to be issued at EPC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39004	15041-20000-24460	300 S GRAND AVE 38th Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Issued	08/03/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	TI to existing high rise commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 6,960.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39005	13041-10000-06517	9149 N WHITE OAK AVE	91325	12	198B129   361	2766006019	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.23729	-118.52024	PV SYSTEM FOR SINGLE FAMILY DWELLING. NONSTANDARD PLAN USING TRANSFORMERLESS INVERTER. CONTAINS AN EXTRA HOUSE PANEL. TOTAL SYSTEM SIZE 6.86 KW.  28 MODULES. DOWNSIZING MAIN BREAKER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39006	18041-20000-23238	23816 W CALVERT ST	91367	3	177B089   406	2045010012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.18156	-118.64526	Plan check for PV roof mounted system, system size: 10.71 kWdc/9.76 kWac-CEC with 34 modules and 2 inverters(5.2kW each).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39007	19041-10000-19739	7039 N TOPANGA CANYON BLVD	91303	3	183B101   268	2024002025	P-1VL-RIO, [Q]C1-1VL-RIO, [Q]C1.5-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.19844	-118.6062	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39008	11041-20000-26553	6633 N BELLINGHAM AVE	91606	2	180B165   314	2322004051	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.19133	-118.39886	New 1.38 KW roof mounted PV system for single family residence.  Applicant is using the M215.  A variance has been filed to use the microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39009	19041-20000-00869	8901 S MANHATTAN PL	90047	8	096A193   182	6036018001	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	33.95618	-118.31027	PV1, NEW ROOFTOP SOLAR SYSTEM CONSIST OF 12 MODULES 12 OPTIMIZER  AND 1 CENTRAL INVERTER SE3800. SYSTEM SIZE IS 3.9KWdc and 3.8KWac.SCOPE INCLUDES NEW 100A SUBPANEL WITH RELOCATED LOADS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39010	16041-20000-38959	20940 W VICTORY BLVD	91367	3	180B109   588	2149003037	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM			PC Approved	11/03/2016 12:00:00 AM	ADDRESS	34.18815	-118.59007	Plan check for energy only. New outdoor lighting installed under canopy and on side of commercial building. 6,408sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39011	17041-20000-12625	6562 N GAZETTE AVE	91306	3	180B109   433	2148023016	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	PIN	34.19005461	-118.58707013	PV1.  Install 5.76 kW roof mounted grid tied PV system.  AC module standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39012	11041-20000-12487	5750 W WILSHIRE BLVD 2nd Floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.06227	-118.3542	T.I. to existing high rise building.  Install general/emergency lighting on partial of 2nd floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39013	14041-10000-02547	8617 W JAYSEEL ST	91040	7	207B189   333	2555034010	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.2656	-118.32068	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(18)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39014	14041-10000-11884	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.09783	-118.36466	T24 only. TOTAL AREA 7327 SQ FT. TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39015	17041-10000-08374	5689 N ASH ST	90042	1	153A227    73	5469035001	R2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.11489	-118.19546	Plan check for PV roof mounted system. System size: 1.59kW with 6 modules and 1 inverter(2.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39016	16041-20002-15917	542 S ALAMEDA ST	90013	14	126A215   141	5163027011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.04014	-118.23809	01/19/2018 Changes to an approved set of plans. All changes have been clouded. Changes have been made to reflect the relocation of electrical distribution equipment and loads. Lighting has been revised and changes have been reflected onto the Title 24 compliance forms.06/15/17 Changes to an approved set of plans.  changes include service load calculations, addition of electric car lift motor and ev charger.*****Previous Work Description*****NEW 1200 AMP SERVICE TO A NEW INDUSTRIAL WAREHOUSE TWO STORIES.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 12030.Note: Building application has been created under 16016-10000-10209	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39017	16041-10000-06873	525 S FLOWER ST	90071	14	130-5A209 135	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.05109	-118.25696	PC FOR T24 ONLY. NEW CANOPY WITH LIGHTING FOR EXISTING RESTURANT AND ADDITION OF 8  HEATERS.  HIGH RISE BUILDING. SCOPE OF THE WORK IS ON GROUND LEVEL.TOTAL AREA 1734 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39018	15041-20001-29255	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	ADDRESS	34.24253	-118.57768	[10/1/15  CHANGES TO APPROVED SET OF PLANS. DELTA 1 CHANGES ONLY. CHANGES TO T24. REDUCING THE NUMBER OF VACANCY SENSORS TO 31]]]]TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39019	14041-20000-23210	9801 N DONNA AVE	91324	12	201B121   294	2762032020	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.24835	-118.54765	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.2KW INTERCONNECTED WITH MSP.(18) KYOCERA TSM-255 MODULES(2) ABB PVI-3.6-OUTD TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39020	12041-10000-20695	3630 N AVENIDA DEL SOL	91604	2	162B161   782	2384012002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.13642	-118.40718	Plan check for new 3.597KW roof mounted Photovoltaic system (Aurora Transformerless inverter) single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39021	13041-10001-31933	1246 N ROSCOMARE ROAD	90077	5	144B145   102	4377021005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.09242	-118.46246	][][expedited per applicant request; plan was submitted on 11/14/13. applicant returned 11/20/13 to expedite plans ][][]Pv1, installing 31 kw DC roof-mounted solar array,  micro inverter: M215 Enphase . 107 module: LG290.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39022	10041-10000-03913	9009 N CANOGA AVE	91304	12	195B105    39	2779018036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.23398	-118.59778	single story fire alarm monitoringsystem. 2 panels and 5 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39023	18041-10000-24846	385 N RIDGEWOOD PL	90004	4	138B189    56	5522028002	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.07827	-118.31472	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM FOR A 5.23KVA AC SYSTEM CONSISTING OF 16 AC MODULES (E20-327-D-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39024	16041-10000-02671	1229 W 38TH ST	90037	8	117B197   448	5037013030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.01743	-118.29841	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac. (12)MODULES-KYOCERA # KU2656ZPA(1)INVERTER- ABB# PVI-3.0-OUTD-S-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39025	19041-20000-03047	1111 N KENMORE AVE	90029	13	144B197   675	5540009009	R4-1D	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Apartment			01/25/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/27/2021 12:00:00 AM	ADDRESS	34.09123	-118.29749	New 24-unit 4-story apartment building with 1200A 240/120V 3ph-4w service. Plan check for power and energy.  Building permit under 17010-10000-04369.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39026	19041-20000-21615	5005 N EDENHURST AVE	90039	13	162B201    20	5593012032	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.142	-118.2736	PV3.  NEW ROOFTOP PV SYSTEM - SYSTEM SIZE IS 199.8KW DC/153.2KW AC.SCOPE OF WORK INCLUDES (540) HYUNDAI SOLAR MODULES WITH (270) P850 OPTIMIZERS, (4) SE33.3K INVERTERS, A SE20K INVERTER, AND DISTRIBUTION.PERMIT 2 OF 2 - OTHER PERMIT IS ROOFTOP SOLAR UNDER 19041-20000-21601.$0 PERMIT FEE PER STATE SENATE BILL SB 1222 AND ASSEMBLY BILL AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39027	17041-20000-46483	5012 N MAMMOTH AVE	91423	4	171B157  1013	2269002020	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.16154	-118.43229	Plan check for solar pv system w/roof-mounted array and AC coupled batter backup system for SFD.5.2kW ungrounded system. (18) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39028	13041-10002-26931	12770 W CASWELL AVE UNITS 1-11	90066	11	111B153  1140	4236019015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Info Complete	08/22/2017 12:00:00 AM	ADDRESS	33.99766	-118.43804	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - SCOPE INCLUDES CHANGES OF UNIT LAYOUT AND ADJUSTMENTS TO SINGLE LINE DIAGRAM(DISTRIBUTION EQUIPMENT AND DISCONNECTS)SCOPE INCLUDES TWO NE  ADA LIFTS ON HOUSE PANEL ORIGNAL PERMIT UNDER 13041-10000-26931PLAN CHECK FOR POWER AND ENERGY FOR A NEW FOUR STORY MULTI-UNIT APARTMENT BUILDING. 11 UNITS TOTAL.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39029	15041-20000-38573	3931 N KINGSWOOD ROAD	91403	4	163-5A145  80	2281014005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.14244	-118.4673	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (23)MODULES-KYOCERA #KU2656ZPA(1)INVERTER- #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39030	19041-20000-06530	870 S HILGARD AVE 1-77	90024	5	135B153   384	4360007028	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.06469	-118.4407	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39031	13041-10000-28051	3518 E 15TH ST	90023	14	117A225   141	5192007006	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.01573	-118.20206	T24 ENERGY PLAN CHECK ONLY. 1470 SQFT , EMERGENCY LIGHTING. WORK ON 1ST AND 2ND FLOOR. PERMIT HAS BEEN PREVIOUSLY PULLED UNDER 13041-10000-22323, T24 ENERGY UNDER INSPECTORS REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39032	13041-20000-19051	850 W BLOOM WALK 2ND FLR.	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	34.0194	-118.28808	T24 FOR EXISTING ARCHITECHTIAL HALL WITH OCCUPANT LOAD LESS THAN 100 FOR THE CLASSROOM. TOTAL SQRFT 3581	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39033	19041-20000-40481	1520 N AMALFI DR	90272	11	132B133   153	4425021020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.0581	-118.50418	INSTALL (8) 2KWH NEW SONNEN STORAGE BATTERY AND (1) INVERTER(8048A) ON EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39034	18041-20000-07601	19314 W CHEYENNE ST	91326	12	207B117   223	2728004028	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.26472	-118.55376	pv1install roof mounted pv system sized 7.6kw interconnected wth msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39035	18041-10000-28636	5366 W 83RD ST	90045	11	099B173   822	4127025005	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Issued	07/31/2018 12:00:00 AM	ADDRESS	33.96344	-118.37271	PLAN CHECK FOR FOR TITLE 24 FOR REMOVAL OF HID FIXTURE TO NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39036	14041-10000-20050	8401 N WINNETKA AVE	91306	3	192B113   222	2781017900	OS-1XL	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM			Reviewed by Supervisor	08/07/2014 12:00:00 AM	ADDRESS	34.22279	-118.57123	PC FOR ENERGY ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES.TOTAL 5684 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39037	16041-20000-15660	10941 W LA TUNA CANYON ROAD	91352	6	195B173   613	2408004029	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.23488	-118.36939	PLANCHECK FOR T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39038	13041-10000-26403	9340 N SANDUSKY AVE	91331	6	198B157   388	2642017017	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.24018	-118.43087	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 3.675 KW DC ON non-standard plan IN A 1-story  HOME. (15) MODULES: TRINASOLAR TSM-245PA05.18(1) INVERTER: POWER-ONE PVI-3-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39039	19041-10000-03613	358 W 38TH ST	90037	9	117A203   152	5122027001	M1-2, [Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Closed	08/03/2020 12:00:00 AM	ADDRESS	34.01475	-118.27886	FULL PC FOR POWER AND ENERGY FOR A 1-STORY COMMERCIAL KITCHEN FACILITY. SCOPE OF WORK INCLUDES A NEW 800A SERVICE,  NEW SITE LIGHTING, AND NEW FEEDERS FOR THE NEW STATE APPROVED (17) INDIVIDUAL KITCHEN MODULES MADE OF SHIPPING CONTAINERS. TOTAL AFFECTED AREA IS 8800 SQ. FT.   NOTE: THE SUB-PANELS AND CIRCUIT WIRING WITHIN THE STATE APPROVED SHIPPING CONTAINER MODULES IS NOT PART OF THE SCOPE OF WORK. WORK IS DONE BY OTHERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39040	17041-10000-10737	13362 W VENTURA BLVD	91423	4	165B157   859	2373003011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1439.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.14674	-118.42452	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 2,000. Total of 9 fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39041	16041-20000-42279	6367 N VAN NUYS BLVD	91401	6	180B149   936	2241004003	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.18626	-118.44902	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy and em lighting only.  total square footage 4220.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39042	19041-10000-41528	10742 W RIVERSIDE DR	91602	4	165B177    93	2423005014	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Issued	10/11/2019 12:00:00 AM	ADDRESS	34.15208	-118.36511	Plan check for a new fire alarm system located in commercial building. Scope include (1) fire alarm panel, (1) communication panel, (1) power supply, and (69) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39043	15041-10003-26235	4800 S CENTRAL AVE	90011	9	111A209    93	5107019001	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	ADDRESS	33.99967	-118.25626	Supplemental PC for T24 only for new lighting in restuarant. Installing new light fixtures. PC for lost set of approved plans. Permit fees covered under 15041-70000-26235 and 15041-70002-26235.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39044	19041-10000-22668	2232 S LINCOLN BLVD	90291	11	108B149   297	4242001032	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	03/05/2022 12:00:00 AM	ADDRESS	33.9947	-118.45367	PLAN CHECK FOR AN EXISTING FIRE ALARM SYSTEM UPGRADE. SCOPE INCLUDES NEW FA CONTROL PANEL, ANNUCIATOR AND COMMUNICATOR  WITH 52 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39045	13041-10000-35241	1245 W WILSHIRE BLVD ste# 100	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	Full plan check for energy and power for a first time tenant for a cafe. Part of  a medical building. Total area 2638 sq ft(Mehdi),  FA variance was s filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39046	15041-10000-38333	1422 W MIRAMAR ST	90026	13	133-5A207 237	5153028016	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Apartment			11/13/2015 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.05956	-118.2617	PC FOR POWER. UPGRADING SERVICE FROM 400A TO 600A. CHANGING BREAKERS  FOR EACH UNIT TO  60 AMPS, NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39047	19041-10000-06227	2450 E CENTURY BLVD	90002	15	091-5A217 110	6046019923	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	33.94627	-118.22941	Full plan check for 1st time tenant, New Gym (BLINK) Scope includes new lighting and equipment with a total area of 16,790 SQ FT, located in a single story commercial building with an existing 1,200 Amp Service dedicated to this tenant.Building Permit: 19016-10000-04848	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39048	17041-10000-24559	10050 S KALMIA ST 101-202	90002	15	091-5A217 107	6046019920	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	33.9463	-118.23163	POWER PLAN CHECK FOR  A 3-STORY, 3-UNIT APARTMENT BUILDING. SCOPE INCLUDING A  400A SERVICE, AND 4 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39049	15041-10000-01634	14540 W KESWICK ST	91405	6	186B149    47	2210031028	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.21015	-118.45022	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 2064 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39050	16041-10001-06827	10469 N SAN FERNANDO ROAD	91331	7	207B161   433	2620028006	M2-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.26046	-118.41643	03/08/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE ADDING A 200A,  240/120V, 3 PHASE, 4 WIRE PANEL.   (((((PC FOR POWER ONLY FOR A NEW 800A SERVICE UPGRADE AND MAIN SWITCHBOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39051	14041-20002-25139	19346 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.23298	-118.55494	PC FOR DELTA 4 REVISIONS. INSTALLATION OF SHUNT TRIP DEVICE. WIRING FOR FUTURE XRAY EQUIPMENT. XRAY NOT GOING IN AT THIS POINT IN TIME. ALL CHANGES CLOUDED DELTA 4.permit already issued. no permit under this application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39052	14041-20000-01506	8115 N DARBY AVE	91335	12	189B125    88	2102003008	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Expired	02/11/2016 12:00:00 AM	ADDRESS	34.21783	-118.53355	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39053	19041-10000-32852	3647 S HUGHES AVE	90034	5	120B165   521	4313008041	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Issued	08/21/2019 12:00:00 AM	ADDRESS	34.02638	-118.40146	PC for a new fire alarm system in a apartment building, scope of work is three new fire alarm panel and 45 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39054	19041-10001-13493	9771 W GLENSIDE PL	90210	5	150B157    85	4384028011	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.10953	-118.4236	Expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39055	14041-10000-14105	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	iNSTALLATION OF 4  LED internally illuminated sign mounted on nearby columns	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39056	19041-20000-08322	333 S HOPE ST 1175	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	T24 PLAN CHECK FOR TI OF EXISTING HIGH RISE COMMERCIAL BUILDING, INSTALLING NEW LIGHTS AND RECEPTACLES, TOTAL SQUARE FOOTAGE = 3230 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39057	18041-20003-09125	13003 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CLOUDED CHANGES ONLY, RELOCATION OF FUTURE EV CHARGER POSITIONS ON ELECTRICAL SITE PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39058	11041-10000-00335	6933 W HOLLYWOOD BLVD A-D	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	ADDRESS	34.10171	-118.34135	TENANT IMPROVEMENT FOR NEW STARBUCKS COFFEE SHOP. CHANGE OF USE FROM RETAIL TO RESTAURANT. 1040 SQ FT; NEW PARTITIONS AT STORAGE AREA TO CREATE 13x26 STORAGE ROOM FOR PROPOSED COFFE SHOP; NEW H/C TOILET ROOM. HOURS OF OPERATION FROM 7:00 AM TO 11:00 PM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39059	19041-10000-22989	19627 W LASSEN ST	91324	12	201B117    79	2726012023	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.25014	-118.56102	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 17 MODULES (Q-CELL 285) , 17 MICRO-INVERTERS (IQ7-60 240).  SYSTEM SIZE IS 4.85KWdc and 4.08KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39060	19041-10000-32518	6333 W 3RD ST 2ND FL-BLOCK S	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.07157	-118.36014	Energy plan check for an office TENANT IMPROVEMENT located on the 2nd floor of a 2-story office building. Scope includes new lighting and equipment with a total lighting area of 1,877-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39061	18041-10001-07287	2139 S CAMDEN AVE	90025	5	126B153   609	4322018013	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.04151	-118.4366	EXPEDITE FOR PV PLANS PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 9.43KWDC/ 7.6KWACSCOPE INCLUDES 29MODULES WITH OPTIMIZER AND CENTRAL INVERTER.(ESS UNDER SUPP).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39062	15041-20000-07452	5013 N GERALD AVE	91436	5	171B137   409	2259017039	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.16172	-118.49362	Plan check for a PV1 roof-mounted PV system. System size is 5.3 kWac and consists of (21) modules and (21) micro-inverters. Standard plan is NOT being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39063	13041-20000-03496	12400 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	04/19/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	33.97727	-118.4065	First time tenant, office low-rise.   PLAYA VISTA PROJECT.  METHANE ZONE.  Full Plan check. Applicant has a pre-cut check, verify fees before approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39064	12041-10000-01172	139 N WESTERN AVE	90004	4	138B193   868	5517003002	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.0741	-118.3095	CHANGE OF USE FROM RETAIL SPACE [2,441 SQ FT], TO COFFEE-SHOP plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39065	11041-10000-00767	6842 N VAN NUYS BLVD 1ST floor	91405	6	183B149   647	2217009011	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM			Not Ready to Issue	02/08/2011 12:00:00 AM	ADDRESS	34.19499	-118.44846	T-24 and emergency lighting plan check for the first floor of a building where there was a change of occupancy from office to private school.    CHANGE OF USE FROM OFFICE (B-OCC)  TO PRIVATE SCHOOL (E-OCC, CHARTER SCHOOL FOR GRADE 9~12) AND INTERIOR NON-STRUCTURAL TENANT IMPROVEMENT ON 1ST , 3RD  AND  4TH  FLOOR OF EXISTING   8 STORY,TYPE I-B, BUILDING. NFPA-13 SPRINKLERED BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39066	12041-10000-16634	4853 N FULTON AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	11/08/2012 12:00:00 AM	ADDRESS	34.15855	-118.42287	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN. BUILDING #2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39067	14041-20001-15796	18125 W ABBEY ROAD	91335	3	177B125   108	2124017089	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.18489	-118.52823	((EXPEDITE FEEs))PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39068	16041-10000-20449	2605 S OCEAN FRONT WALK	90291	11	105A145   285	4226019002	RD1.5-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Expired	07/16/2018 12:00:00 AM	ADDRESS	33.98147	-118.46884	PV2, rooftop solar installation, 3.0 kW Ac system,    (12) Solar city standrad module    (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39069	18041-10000-45662	7301 S VERMONT AVE	90044	8	102B197  1331	6019020012	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.9733	-118.29197	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39070	15041-10001-40569	518 E COMMERCIAL ST Pump House	90012	14	130-5A215  71	5173002901	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05288	-118.23427	PC only due to lost approved set.This is 3 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************One-story Pump House	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39071	09041-10003-24074	600 W WORLD WAY TERMINAL 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	TERMINAL 6  RENOVATIONS-  RELOCATING ALASKA AIRLINES OFFICES TO  NEW AREAS  ; (((((((changes made to prevviously approved set. see fee list. 10-17-12))))))))) REMODEL BAGGAGE HANDLING AREA  WHICH IS AWAY FROM THE PASSAGENER AREA(((    Changes made to prviously approved set.(((((changes made to previously approved set, complete titl24, 120 new revised and or added circuit, and one panel , ))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39072	16041-20000-18346	6250 N TOPANGA CANYON BLVD #1575	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. PERVERSE SUNGLASSES IN THE TOPANGA MALL. UNIT 1575	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39073	19041-20000-29918	10824 W BURBANK BLVD	91601	2	174B173  1015	2416014016	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.17199	-118.3668	Plan check for power and energy for Tenant improvement in commercial property. 800A Service. B#19016-20000-01998	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39074	18041-10000-47963	712 S LINCOLN BLVD	90291	11	111B145   851	4243030004	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	33.99969	-118.46402	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 1625 SQFT AREA.bld# 18016-10000-36794	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39075	14041-20000-23362	23339 W KESWICK ST	91304	12	186B093    40	2027001014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Expired	09/27/2016 12:00:00 AM	ADDRESS	34.20966	-118.63712	PV1 SFD. TOTAL SYSTEM SIZE 10 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTER. USING TOTAL OF 44 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39076	16041-20001-36124	22714 W CREOLE ROAD	91364	3	168B097   564	2074010025	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.15518	-118.62271	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19.5 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39077	19041-10000-04587	2115 W BEVERLY BLVD	90057	13	136-5A205 307	5157020011	C2-1	Central	Westlake	Echo Park		2085.01	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Info Complete	04/23/2019 12:00:00 AM	ADDRESS	34.0671	-118.27084	INSTALL A NEW 250KW GENERATOR FOR A T-MOBILE CELL SITE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39078	19041-20000-49880	4224 N SALTILLO ST	91364	3	165A107   265	2172023054	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			Reviewed by Supervisor	12/12/2019 12:00:00 AM	ADDRESS	34.14632	-118.59346	PV1.  Install 8.65 kW DC roof mounted grid tied PV system.  (148) PV shingles with 3.8 and 5.2 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39079	14041-10000-05917	410 N BARRINGTON AVE	90049	11	135B141    80	4429021054	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.06949	-118.47343	"PV1. ROOFMOUNTED UNGROUNDED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 18.84 kW DC. "" $0 permit fee is due to the 2012 Senate Bill No. 1222""(60) BOSCH C-SI m 60 265 MODULES(12) BOSCH C-SI m 60 245 MODULES(3) PVI-6000  208 VAC POWER ONE INVERTER"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39080	12041-10000-18932	1995 E 20TH ST	90058	14	118-5A215  76	5167006037	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.01799	-118.23629	800Amp Service upgrade, new lighting, receptacles, equipment.  Project is in a Methane Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39081	14041-10000-23951	888 S FIGUEROA ST SUITE 480	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM			PC Approved	09/02/2014 12:00:00 AM	ADDRESS	34.0465	-118.26225	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF OFFICE. SUITE 480, 1630 SQFT, EMERGENCY LIGHTING.  ""COMPLY WITH DEPARTMENT ORDER effective date 01/10/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39082	17041-10000-08292	735 S BROADWAY 1ST FLR	90014	14	127-5A209  71	5144014031	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.04448	-118.2543	T-24, PC FOR ENERGY ONLY. INTERIOR T.I. TO (E) 2,800 SQFT RETAIL SPACE TO ADD 2 NEW RESTROOMS ON THE FIRST FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2660 SQ. FT. B#16016-20000-21708	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39083	18041-20000-20407	2306 S WALNUT AVE	90291	11	111B149  1341	4242031018	R1V2	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	33.99657	-118.45089	Plan check for battery back up with PV roof mounted system. System size: 7.6kW with 16 modules, 1 inverter(7.6kW) and 1 battery backup LG Chem Li-Ion Energy.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39084	11041-20000-17485	14480 W SHERMAN WAY BLDG B	91405	6	183B149    66	2217007053	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM	08/22/2011 12:00:00 AM		Permit Closed	04/25/2014 12:00:00 AM	ADDRESS	34.20098	-118.4485	PLAN CHECK T24 ENERGY TI FOR EXISTING RETAIL STORE.  PERMIT FOR LIGHTING AND ELECTRICAL TI WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39085	18041-10000-10869	7855 N HAYVENHURST AVE	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.21329	-118.49262	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39086	15041-10001-22992	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	(      2-19-16  M.Z  changes made to previusly approved set ,  title 24, ckts  power lighting ))    FULL PC, TI TO AN EXISTING RETAIL BUILDING 4 STORIES. SCOPE OF WORK INCLUDES NEW LIGHTING ON THE 1, 2, AND PARTIAL 3RD FLOOR. CONNECTED LOAD OVER 400A. TOTAL SQ. FT. = 209772    PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39087	08041-20003-13390	5040 W SANTA MONICA BLVD	90029	13	144B197   781	5538002035	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.09059	-118.29899	Changes from previously approved plans.  Changes include load on panels HL1, HL2, HL3 only.  All changes indicate by DELTA 3 as shown on plans.  No changes in lighting.  Plan check for power only.*****First tenant build-out for coin laundry.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39088	13041-20000-35364	6925 W HOLLYWOOD BLVD	90028	13	147B181   112	5548004022	C4-2D-SN, R4-2D	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.10171	-118.34113	"Change to lighting in the ""box office"" at TCL Chinese Theatre, inside lighting and outside lighting.  Relocate Transformer and Panel.  Load is less than 400 amps, this area is not a place of assembly per the Engineer.  NO EMERGENCY LIGHTING PER APPLICANT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39089	13041-10000-35519	1640 N MOHAWK ST	90026	13	142-5A207 151	5423010021	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.08552	-118.26143	PV1, Install 5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (20) modules: YINGLI YL250P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39090	14041-10000-12707	906 W SEPULVEDA ST	90731	15	018B197   552	7447009015	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	33.74574	-118.29698	Install roof mounted solar array interconnect with main pannelsystem size = 4.08 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39091	15041-10000-39966	929 W JEFFERSON BLVD	90007	9	120A201     4	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			11/25/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.02454	-118.28542	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR USC BUILDING 6. 1381 DEVICES AND 1 FIRE ALARM CONTROL PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39092	13041-20001-03947	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.0346	-118.45665	Modifications to approved set.  Inverter for emergency power added.  Plan check for modifications to Title 24 only.   (((PERMIT TO BE ISSUED BY PC ONLY PC FOR ENERGY ONLY. TI TO EXISTING BLDG (RESTROOMS AND OUTDOOR LIGHTING). LESS THAN 400A)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39093	15041-20001-43900	4183 S NORMANDIE AVE	90062	8	114B193   946	5021016040	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM			PC Approved	01/15/2016 12:00:00 AM	PIN	34.00744303	-118.30051295	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (20) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39094	15041-20000-05668	8053 W BEVERLY BLVD	90048	5	138B177   392	5514007045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	34.07625	-118.36499	PLANCHECK FOR T24 ENERGY TO COMPLY WITH INSTALLTION WITH OUT PERMIT.  GYM . 6496 SQFT, EMERGENCY LIGHTING.  COMPLIANCE WITH 2008 ENERGY CODE. INSPECTORY TO VERIFY EXISTING INSTALLTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39095	13041-10008-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM			PC Approved	01/14/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	Bullettine 15: add luminaires and circuits in the baggage & re-route officesPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39096	15041-10001-37959	1131 S SWALL DR	90035	5	132B169   617	4332011034	R2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.05629	-118.38581	Changes to approved set.  Downsizing inverter from 6 kWac to 3 kWac and from 25 modules to 13 modules.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(25) KYOCERA MODULES (1) ABB PVI-6000 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39097	15041-10001-03684	7337 W PACIFIC VIEW DR	90068	4	156B177   611	2428016005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM			Reviewed by Supervisor	02/19/2015 12:00:00 AM	ADDRESS	34.12144	-118.35321	Supplemental application for expedite feesInstallation of roof mounted solar PV array.  Total system size = 10.2 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39098	12041-10001-09851	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	Delta #2 and #3 Revision to approved plans. Changes to type of light fixtures installed and T24 calculation for Suite #K60.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39099	14041-20000-26875	7112 N CANBY AVE	91335	3	183B125   320	2125002005	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Closed	11/25/2015 12:00:00 AM	ADDRESS	34.1998	-118.53462	PC FOR NEW 600A SERVICE. RELOCATE AND PROVIDE NEW SUBPANELS. PC FOR POWER AND ENERGY DISTRIBUTION.LIGHTING TO BE EXISTING, NO ADDITION OR MODIFICATIONS TO BE MADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39100	17041-10000-37323	12907 W SUNSET BLVD	90049	11	132B137   407	4406009015	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.05724	-118.49153	PLAN CHECK FOR A BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF AN (E) PV SYSTEM AND (N)TESLA POWER WALL 2-BATTERY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39101	16041-20000-33339	2806 N HYPERION AVE	90027	4	151-5A205 199	5434036008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.10822	-118.27157	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 541 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39102	09041-10002-23701	6801 W HOLLYWOOD BLVD Suite 105	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM			PC Approved	06/15/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	Delta 8 changes to permitted set of electrical plans for the Hollywood  Hard Rock Cafe	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39103	17041-20000-35986	5585 N RESEDA BLVD 2nd Floor-Restrooms	91356	3	174B125   396	2160004070	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.1721	-118.5362	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 256 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39104	19041-30000-19185	8635 W 3RD ST Suite 960-990	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.07373	-118.38073	ti to an existing medical office.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39105	11041-10000-01450	6625 S STANFORD AVE	90001	9	102B205    56	6007018015	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM			PC Info Complete	04/11/2011 12:00:00 AM	ADDRESS	33.97901	-118.2631	UPGRADE OF SERVICE AND NEW MOTORS AND DISTRIBUTION AND PANEL BOARDS FOR A RECYCLING FACILITY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39106	15041-10000-35253	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	Etihad Airways lounge tenant improvement in Tom Bradley International Terminal.  Plan check for power and energy.  Plan checker to verify service and distribution load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39107	18041-20000-29786	20817 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.29526	-118.58732	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39108	16041-10000-03963	1919 S HOOVER ST	90007	1	126A201   203	5056028023	CM-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.03932	-118.28433	NEW CVS PHARMACY . 400A 480/277V MS. total area indoor 16,688sq.ft, outdoor 33,574sq.ft.**New plan check is performed under 16041-10001-03963 due to a lost master plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39109	18041-10000-21842	12714 W HORTENSE ST	91604	2	168B161   810	2362023007	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.15479	-118.41014	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.385KWdc / 9.920KWac. ALSO DERATING MAIN BREAKER TO 175A. (31) AC MODULES-SUNPOWER X21-335-BLK-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39110	16041-10000-34100	1706 W 38TH ST	90062	8	117B193   806	5035030016	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Expired	09/10/2023 12:00:00 AM	ADDRESS	34.01724	-118.31118	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(12)MODULES-RENOGY RNG-250D(12)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39111	15041-10000-16949	8126 S LINCOLN BLVD	90045	11	099B157   381	4113018027	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	33.9631	-118.4218	New hydrogen fueling station located on site of existing gas station.  Class I Div 2 hazardous locations within scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39112	10041-10000-15937	7300 W HOLLYWOOD BLVD	90046	4	147B181   182	5550016024	[Q]R5-1	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	34.10144	-118.34913	Phase 1 of installing a revised fire alarm sytem in the building.  The new FACP will interface with the existing FACP, but not with the existing devices.  The new devices will be installed only on the lower level.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39113	18041-10000-40170	12100 W WILSHIRE BLVD #1750	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.0438	-118.46755	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT WORK ON +/- 6,314 SQFT. INSTALL NEW LIGHTING ONLY, AND REPURPOSE EXISTING BRANCH CIRCUITS.(B# 18016-10000-28203)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39114	18041-20000-34502	10419 W DUNLEER DR	90064	5	123B161    22	4318021023	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.03702	-118.41235	Plan check for PV roof mounted system, system size: 10.23 KW DC, 9.4KW AC with 31 PV modules and 31 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39115	19041-20000-38024	5189 N LLANO DR	91364	3	171B101   951	2075033014	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.16232	-118.61379	Plan check for PV roof mounted system, PV system size: 11.34KW with 36 PV modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39116	18041-10000-22743	5500 N CANOGA AVE BLDG 31	91367	3	174B105    40	2149016026	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.17032	-118.59721	PLAN CHECK FOR TITLE 24 ONLY FOR OFFICE TI - TOTAL AFFECTED AREA 2478 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39117	14041-10000-34669	1150 S OLIVE ST 29th floor	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	34.03962	-118.26181	Plan check for Title 24 only. Project site is a single existing conference room (commercial). Buuilding is high rise. Total lighting area = 353 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39118	12041-10000-23269	3360 W OLYMPIC BLVD	90019	10	129B193   298	5081030024	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	34.05243	-118.31159	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR SUITE#100 BANK TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39119	13041-10001-29593	1221 S SIERRA BONITA AVE	90019	10	129B177   162	5085021035	R1-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.053	-118.35802	Expedited RSES plan check per applicant request. ((((PV1.  Install 4.75 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE5000A-US.  19 modules: Hanwha Hsl60p6-PB-4-250TW.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39120	10041-20000-21803	4770 N LANKERSHIM BLVD	91602	4	168B173   512	2421015001	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.1573	-118.36977	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR RESTAURANT TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39121	17041-10000-44237	205 1/2 N LAKE SHORE TER	90026	13	135A207   195	5159017009	R3-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.06457	-118.26115	PC for 3.8 kW roofmounted solar PV.  Installing 11 modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39122	14041-20000-06851	10361 N SOPHIA AVE	91344	12	204B137   108	2679024022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.25908	-118.48758	Roof PV system with system size 7.28KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39123	16041-20000-11083	16014 W YARNELL ST	91342	7	228B141   255	2603018027	R1-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	PIN	34.32068014	-118.47895192	Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (2) inverters, (34) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39124	15041-10000-14767	155 S OXFORD AVE	90004	10	138B193  1207	5517006027	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Apartment			05/14/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Issued	06/01/2015 12:00:00 AM	ADDRESS	34.07206	-118.30822	Installation of new fire alarm system with 145 devices and 1 panel. 5-story plus 21 units, two parking levels buldings.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39125	12041-20000-13490	6600 N TOPANGA CANYON BLVD 1100 A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/11/2012 12:00:00 AM			PC Approved	06/29/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T24 lighting plan check for a TENANT IMPROVEMENT in space 1100A - PARTITION WALLS, NEW ACCESSIBLE DRESSING ROOM,  SHELVING AND ASSOCIATED ELECTRICAL/PLUMBING FOR RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39126	12041-10000-25109	10250 W SANTA MONICA BLVD COFFEE-KIOSK	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	PROVIDE POWER TO A COFFEE BEAN TEA LEEF KIOKPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39127	15041-10002-36118	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.24205	-118.59773	PC FOR RECHECKING PLANS PER NEW CONTRACTOR DESIGN BUILD. PERMIT AND CONSTRUCTION TO REMAIN UNDER THIS APPLICATION. NEW PLAN CHECK AND TRANSFER OF PERMIT TO NEW CONTRACTOR UNDER THIS APPLICATION. ALSO MODIFICATIONS TO LOCATIONS OF SERVICE, INVERTERS AND WIRING METHOD FROM INVERTER TO AC LOAD CENTERS. PC FOR CHANGES COUDED BLUE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39128	19041-20000-24147	5242 W 104TH ST	90045	11	090B173   290	4129035013	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.94183	-118.37188	PV3.  Install 97.3 kW DC / 87.1 kW CEC-AC / 100.0 kW AC roof mounted grid tied PV system.  (278) modules with optimizers, 100 kW rated inverter, and zig-zag transformer.  $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39129	13041-10000-21235	845 N FULLER AVE 1-9	90046	5	141B181    50	5526006010	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Apartment			08/08/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.08659	-118.35007	NEW BUILDING. POWER AND ENERGY PLAN CHECK. 9 UNIT APARTMENT. 4 STORIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39130	14041-10000-16478	5177 W PICKFORD ST	90019	10	126B181   290	5067001015	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Apartment			06/19/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.04402	-118.35229	PV1, INSTALL 3.57 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 4 UNIT PROPERTY, INTERCONNECT WITH MAIN SERVICE PANEL. ON TRANSFORMERLESS INVETER, WITH OPTIMIZERS.(14) MODULES: TRINA SOLAR # TSM-255PA05.18(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3800A-US-ZB-Umodule bonding method: lay-in lugs	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39131	14041-20001-13912	10700 W SANTA MONICA BLVD 2ND FLR	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	pc for changes to approved set of plans. new lighting count. t24 energy only. changes only. all changes clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39132	13041-20000-22593	12866 N GLENOAKS BLVD	91342	7	222B153   349	2508016011	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.30449	-118.44542	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.92 KW. 16 MODULES AND 1 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39133	13041-10000-07178	21650 W OXNARD ST 11TH-12TH FL	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	INSTALLATION OF NEW ATS AND 400A DISTRIBUTION BOARD. FEEDING 3 SUBPANELS FOR IT  LOADS. GENERATOR AND A COUPLE OTHER SUBPANELS ARE PART OF ANOTHER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39134	14041-20003-03004	7343 N RESEDA BLVD	91335	3	186B125   756	2118015003	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			07/27/2018 12:00:00 AM			PC Approved	07/27/2018 12:00:00 AM	ADDRESS	34.20424	-118.53632	07-27-2018 Changes to an approved set of plan changes include clouded area as delta 1. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39135	17041-20000-16711	11134 N ENCINO AVE	91344	12	210B129   247	2711011023	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.27315	-118.51512	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (43) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39136	13041-10001-34539	3643 N LOWRY ROAD	90027	4	154-5A203 157	5592010003	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Corrections Issued	01/28/2014 12:00:00 AM	ADDRESS	34.11766	-118.2778	Expedited RSES plan check per applicant request.{{PV1, Install 4.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (18) modules[YINGLI # YL250P-29b] on a 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39137	18041-20000-00832	11970 W VENTURA BLVD	91604	2	162B169   151	2369016034	C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	PIN	34.14319764	-118.39263254	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy only.  Note: panels to be replaced with one for one	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39138	10041-20001-03158	15305 W LANARK ST	91406	6	189B145    41	2654037029	R4-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Apartment			04/05/2010 12:00:00 AM			PC Approved	04/05/2010 12:00:00 AM	ADDRESS	34.21785	-118.46738	Delta 6 revisions to 10041-20000-03158. changing AIC rating of main switch board from 100 to 65.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39139	14041-20000-33448	16121 1/2 S HOOVER ST	90247	15	069B197   252	6120020011	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	PIN	33.8846323	-118.28738151	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.2kW. Ungrounded system.15  327W pv modules across 2 strings (8+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39140	18041-20000-22268	1814 N WEBSTER AVE	90026	13	145-5A205 296	5431031009	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.0922	-118.26919	Plan check for the addition of a battery back-up system onto an existing PV1 roof-mounted PV system. Back-up system consists of (2) PowerWalls and (2) load centers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39141	15041-20002-29951	5961 N LAUREL CANYON BLVD	91607	2	177B165   793	2340004029	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	PIN	34.17892385	-118.39694996	changes to an approved set of plans.  changes to include field conditions.  gas station 1 and 2 panels connected to gas station panel.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39142	18041-20000-28160	11472 N SANTINI LANE	91326	12	213B109   424	2701068027	RZ4-1	North Valley	Chatsworth - Porter Ranch	Chatsworth, Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.28018	-118.58817	addition of (1) tesla energy batterry storsage 14KWh to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39143	13041-10000-06055	111 E UNIVERSAL HOLLYWOOD DR 10UCP-N. LOBBY	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM			PC Approved	03/07/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING FITNESS CTR- 10UCP N. LOBBYPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTPERMIT TO BE OBTAINED AT THE ELECTRICAL COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39144	16041-20000-21217	10342 W DIAMOND ST LOT 12	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39145	13041-10001-04928	1375 N WESTERN AVE	90028	13	147A193   196	5544030055	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	PIN	34.09622604	-118.30960264	SERVICE UPGRADED TO 800A OVERHEAD;NO CHANGES TO THE LOAD(((((((((PC IS FOR T24 ENERGY. BUILDING ADDITION AND RENOVATION FOR AN EXISTING RESTAURANT; EXPAND RESTAURANT INTO (E) POST OFFICE (CHANGE OF USE FROM POST OFFICE TO RESTAURANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39146	10041-10002-15136	1521 W FRANCISCO ST Bldg A	90501	15	057B193    25	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	33.8496	-118.30518	New building.  New service, panels, and branch circuits.  Plan check for energy and power.NOTE: refer to 10041-10K-15139 for  Bldg B 99((((((((((((((((((((   title 24 changed by addition of 5 lights.)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39147	15041-10000-19129	1419 E 23RD ST	90011	9	118-5A211 176	5119026006	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.01916	-118.25053	PV1, ROOF MTD., 23 MODULES, 1 INVERTER 5.0 KW AC. XFORMERLESS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39148	15041-10000-42747	2647 S TILDEN AVE	90064	5	123B157   793	4256018025	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.03269	-118.43003	PV1, ROOF MOUNTED SOLAR SYSTEM. (10) MODULES AND (10) 215W MICRO-INVERTER. TOTAL SIZE: 2150W	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39149	16041-10000-11631	7247 N ARIEL AVE	91335	3	186B121  1012	2104035023	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.20262	-118.54584	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(24)MODULES-CANADIAN SOLAR CS6X-315P(24)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE7600A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39150	17041-20001-08103	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			PC Approved	03/16/2017 12:00:00 AM	ADDRESS	34.04804	-118.46227	3.16.2017 - Verify location/wiring of emergency fixtures per inspector request.======ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 1558.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39151	17041-20000-05709	18734 W VENTURA BLVD	91356	3	174B121   566	2161008005	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.17088	-118.54186	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,597 sq. ft.Note: Building application has been generated under 16016-20000-30895	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39152	10041-10000-14297	1600 N VERMONT AVE	90027	13	147B197   471	5542014032	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM			Corrections Issued	07/23/2010 12:00:00 AM	ADDRESS	34.09994	-118.29154	Install outdoor general lighting for Chase Bank.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39153	14041-20000-23460	14701 W GERMAIN ST	91345	7	207B149   705	2648014043	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.26187	-118.4519	PV1 SFD. TOTAL SYSTEM SIZE 7.6KW AC USING TRANSFORMERLESS IVNERTER USING STANDARD PLAN. USING POWER OPTIMIZERS.FIRE DECLARATION SIGNED PER REQUIREMENT NO. 96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39154	17041-10000-24507	11211 W VANOWEN ST	91605	2	183B173   198	2319005034	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.19409	-118.37593	Plan check for Title 24 only in existing space, replace existing outdoor fixtures with LED fixtures. Total area:  5,600 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39155	16041-10000-33187	231 E WINSTON ST	90013	14	129A213   318	5148007008	C2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.04601	-118.24613	Plan check for T24 oly, Remove indoor + outdoor HID fixtures abd replace with LED fixtures.  Total area: 8,340 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39156	19041-20000-34447	10965 W BLUFFSIDE DR	91604	2	162B173   234	2366021003	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	08/03/2021 12:00:00 AM	ADDRESS	34.14159	-118.36889	$0 fee per AB 1414.Plan check for PV roof mounted system, PV system size: 43.2KW AC, 55.12KW DC, with 149 PV Modues and 1 inverters(43.2KW). One plan has 2 applications. 19041-20000-34431 and 19041-20000-34447	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39157	19041-10001-14630	1494 N MORAGA DR	90049	5	147B145   212	4377039007	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM			PC Approved	05/08/2019 12:00:00 AM	ADDRESS	34.09492	-118.46897	Expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39158	18041-20000-45368	19436 W VENTURA BLVD	91356	3	174B117   331	2163002016	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.17256	-118.55704	Plan check for Title 24 Energy only Daycare/Preschool Facility T.I. Total area: 5260 sq ft. B#18016-20000-33911	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39159	16041-10000-45841	8420 N BALBOA BLVD #115	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A NEW RESTAURANT. SCOPE INCLUDES NEW PANELS, NEW LIGHTS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 2224 SQ. FT.  B#16016-10000-31178	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39160	18041-30000-00802	633 W 5TH ST 57th Floor-Corridor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only in existing space, T.I. in corridor high-rise building. Total area: 875 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39161	19041-20000-00777	11350 W PALMS BLVD	90066	11	117B157   350	4249026028	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	10/06/2020 12:00:00 AM		Permit Finaled	11/17/2021 12:00:00 AM	ADDRESS	34.01769	-118.42601	New fire alarm system.  (128) signaling line and notification appliance devices with FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39162	19041-10000-06334	2188 N MANDEVILLE CANYON ROAD	90049	11	138B133   495	4493003023	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.07625	-118.49931	*This is plan check only for the accessory recreation room . Electrical permit is covered under combo Building Permit # 16010-10000-04870 ((B# 16010-10000-04870 - Main House,  B# 16010-10000-04871 - Rec. Room,  B# 16041-10000-04872 Utility & Storage structure))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39163	17041-20000-41856	15760 W VENTURA BLVD Suite 2007	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check for energy only. TI to office suite 2007 in high rise building. New lighting (incl. emergency) - 1,993sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39164	14041-20001-07576	5732 N WILLIS AVE	91411	4	174B149   434	2244017006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.1749	-118.45504	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39165	15041-10000-02471	8301 W BEVERLY BLVD	90048	5	138B173   395	5514009027	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.07623	-118.37013	ALTERATIONS IN RETAIL STORE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39166	18041-10000-38389	1516 S GRANDE VISTA AVE	90023	14	118-5A223 179	5190030003	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Issued	10/09/2018 12:00:00 AM	ADDRESS	34.01747	-118.20951	Remove outdoor HID fixtures and replace with new LED fixtures - T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39167	19041-10000-49562	945 N OXFORD AVE	90029	13	144B193  1239	5535021022	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	04/07/2021 12:00:00 AM	ADDRESS	34.08755	-118.30803	Plan check for fire alarm system, 1 FACP and 12 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39168	14041-20000-04789	250 E 1ST ST STE #801	90012	14	130-5A213 150	5161016014	[Q]C2-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.05038	-118.24114	t24 part 6 energy for commercial space. projected area in lighting scope of work is approx. 1100 sq ft. plan check and permit under same application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39169	19041-20001-35844	15618 W DORIAN ST	91342	7	225B145   141	2501024008	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM			PC Approved	09/16/2019 12:00:00 AM	ADDRESS	34.31561	-118.47176	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO SINGLE LINE, REDUCTION OF CONDUCTOR SIZE FROM 4 AWG TO 6 AWG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39170	14041-10000-27847	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX TERMINAL 1. CHANGING OF THE POWER DISTRIBUITION SYSTEM AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39171	19041-20000-28976	18442 W MURAL PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Issued	08/19/2019 12:00:00 AM				new sfd 600 amp service.  plan check for power only.  permit fees paid under building combo permit 18010-20000-05056.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39172	17041-10001-00022	501 E TERMINAL WAY	90731										Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM			PC Approved	11/21/2018 12:00:00 AM	ADDRESS	33.7422	-118.26534	PLAN CHECK FOR CHANGES TO PLAN CHANGES INCLUDE UPGRADING SERVICE SIZE TO 1500A USING 2000A DISTRIBUTION BOARD, UPDATED AIC RATING OF ALL EQIPMENT WITH PROVIDED FAULT CURRENT REPORTS AND ADDITION OF NEW EQUIPMENT - CHANGES TO ORIGINAL SUBMITTAL ARE >50. ELECTRICAL POWER PLAN CHECK REQUIRED ORIGINAL PERMIT PC FOR POWER. REFEED 4160 V , 1200A 3PHASE SERVICE, ONE NEW 4160 V, 1200A 3P 4WSERVICE, AND ONE  2400V 2000A 3P. SCOPE INCLUDES REPLACEMENT AND RELOCATION OF EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39173	14041-20001-17155	1154 N HIGHLAND AVE	90038	4	144B185   509	5532020002	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.09225	-118.3384	Titel 24 only, modified lighting.  Permit is existingTittle 24 plan check only on a 1895 SQ feet  partial area from a commercial building under permit #: 14041-90000-14333	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39174	19041-10000-49351	1307 W 84TH PL	90044	8	097-5A197 145	6033003022	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	33.96175	-118.29848	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.610KWdc / 3.00KWac.(9)MODULES- REC SOLAR 290290TP2 BLK(1)INVERTER-NINGBO GINLONG TECH SOLIS-1P3K-4K-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39175	19041-20000-44128	806 E 3RD ST	90013	14	129A215   316	5163015028	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	02/14/2020 12:00:00 AM		Permit Finaled	10/19/2020 12:00:00 AM	ADDRESS	34.04564	-118.23594	Power and lighting for tenant improvement.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39176	15041-20001-10556	14415 W TERRA BELLA ST	91402	6	198B149   349	2639009***	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Apartment			04/09/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.23767	-118.44686	EXPEDITED PER APPLICANTS REQUESTPV2. MULTI FAMILY UNITS. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.16KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39177	17041-30000-04779	6821 S VICTORIA AVE	90043	8	102B185   577	4006023004	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	33.97624	-118.33248	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 800 amps and new distribution equipment only. No load is included as part of this scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39178	15041-10000-15303	1800 CENTURY PARK EAST LEV A-7	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	PIN	34.06270629	-118.4150769	INTERIOR RENOVATIONS OF LOCKER-ROOMS, CORRIDOR, LOBBY AND SUPPORT AREA PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39179	14041-20001-06543	5701 N LASAINE AVE	91316	5	174B133   380	2254019014	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM	ADDRESS	34.17425	-118.51056	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM WITH SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39180	17041-10000-11258	1246 S GLENDON AVE	90024	5	132B153   501	4325005928	[Q]C2-1LD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.05786	-118.44187	PC FOR REPLACEMENT OF MAIN FA PANEL AND ADDITION OF 1 DEVICE. FA PANEL IS REFEEDING EXISTING NOTIFICATION AND INITIATION DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39181	15041-10000-37487	1674 W HILL DR	90041	14	163-5A225  72	5669018001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	01/23/2016 12:00:00 AM	ADDRESS	34.14358	-118.20282	PV1, INSTALL  8.7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, WITH BATTERY CHARGE, AND  ONE 100A  SUB PANEL. MAIN PANEL 400A. (1) INVERTER : CONEXT XW+ SERIES XW+6848NA(24) MODULES: SUNBODULES PRO-SERIES SW 315-320 MONO	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39182	11041-20000-05379	10960 W WILSHIRE BLVD ste 1250	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	energy plan check suite 1250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39183	16041-10000-40635	767 S ALAMEDA ST #233	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE FOR SUITE #233. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 8804 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39184	15041-10000-00897	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"Plan check for T-24 only. Replace existing fluorescent light sign to LED. Retrofit existing fluorescent light sign to LED. sing with with new face Panel. Added new LED sign connect to existing power circuit. Rfference Building Permit: 14048-10000-02680PROPOSED 4'-6"" X 8'-6"" S/F ILLUM. POLE SIGN (4-1)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39185	19041-20000-29487	4005 N MARY ELLEN AVE pv1	91604	2	162B157   265	2385005051	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.14267	-118.41984	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39186	16041-10000-11561	11048 W OLYMPIC BLVD	90064	5	126B153   712	4322017001	R3-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Apartment			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.04076	-118.43659	New F.A system for a new 4-story, 8-unit apartment. (1) F.A panel   (1) F.A Comm panel    (38) F.A. devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39187	14041-20000-04982	7112 N FORBES AVE	91406	6	183B133   322	2225017015	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.19953	-118.49884	Roof mounted PV system with 3.25KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39188	11041-10000-25985	2850 E OLYMPIC BLVD	90023	14	120A221   132	5170026009	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	08/10/2012 12:00:00 AM	ADDRESS	34.02252	-118.21622	New retail (Dollar Tree) in a previous light manufacturing building.  Two new sub panels, circuits and lighting.  Full plan check requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39189	14041-10008-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.0504	-118.26023	10/17/16Changes to an approved set of plans. All changes are clouded under delta 8. Revise loads across panel schedules, addition of a 30kva transformer, and few circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39190	13041-20001-03240	5077 N LANKERSHIM BLVD 1-130	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM			PC Info Complete	02/28/2014 12:00:00 AM	ADDRESS	34.1626	-118.37361	Changes from previously approved plans.  Changes include 2 change units, change in floor plan to allow extra community rooms, changes in T-24.  Plan check for power and energy.  All changes indicate by DELTA 4 and DELTA 5.*****New 4-story, mixed use building.  3000 amp service.  Full Plan Check.  Variance to separate fire alarm plans has been filed.  *****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39191	14041-10000-09257	777 S FIGUEROA ST SUITE 1390	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.04828	-118.26116	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK IS ON SUITE 1390	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39192	16041-20001-11973	22701 W CLARENDON ST	91367	3	174B097   887	2040020013	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.16934	-118.62132	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD and it's detached garage. Interconnect with a 225A MSP.System size: 14kW (3+5+6). Ungrounded system. (44) 327W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39193	18041-10000-35874	4855 W PICO BLVD	90019	10	129B181   913	5070001035	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.04825	-118.3428	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39194	17041-10000-15380	624 S GRAND AVE	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.04802	-118.25572	Plan check for power and Title 24.  Installation of four (4) new medium voltage switchgears for connection to a temp' backup genset.  Three new transformers and a new 480 V distribution panel for connection to existing loads.  New electrical room lighting.  Total area = 260 sq. ft.       Building permit #17016-10000-12057	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39195	16041-20000-03289	12009 N LONGACRE AVE	91344	12	216B125   410	2601031041	(T)(Q)RE40-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.28923	-118.53015	PLANCHECK FOR GROUND MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY RESIDENCE.  SYSTEM SIZE: 20 KWBUILDING PERMIT: 16020-20000-00212	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39196	12041-20000-13115	8720 S WESTERN AVE	90047	8	096A193    12	6037014027	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	33.9585	-118.30883	T.I. to existing building in suite 101, 102, and 103.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39197	13041-10000-11340	6022 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	ADDRESS	33.94182	-118.39269	PLAN CHECK POWER AND ENERGY.  AMERICAN AIRLINES REMOTE TERMINAL TI. (PHASE V)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39198	13041-10000-31391	7241-7245 N ETON AVE	91303	3	186B105   986	2111017033	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	12/24/2013 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.20229	-118.5956	PLAN CHECK FOR POWER. INSTALLING A NEW 800 AMP SERVICE AND NEW PANELS. ALL LOADS EXISTING TO REMAIN. (TWO BUILDINGS 1 OF 2) VARIANCE TO PERMIT MORE THAN ONE FEEDER TO SUPPLY A SEPARATE BUILDING APPROVED BY P. GILBERT 12/9/13	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39199	11041-20000-26063	2055 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.03954	-118.44303	First time tenant for Nong LA restuarant.  Install a 200A subpanel and branch circuits.  Plan check for power and energy.  Note: all other switchgears and panels are existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39200	11041-10000-15952	7153 N LINDLEY AVE	91335	3	183B125   225	2125036112	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.20058	-118.52749	T.I.  Existing 7-11.  Renovating the light fixtures in the retail area only.  Replacing light fixtures with LED's.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39201	19041-20000-52301	20554 W PESARO WAY	91326	12	210B109   379	2701050076	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.27507	-118.58098	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 8.76KW DC/6.96KW AC. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39202	19041-10000-21699	13336 W AZTEC ST	91342	7	225B157   339	2510024008	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.31503	-118.42316	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 25 MODULES (LONGI 305) WITH MICROINVERTERS (IQ7-60-2-US). SYSTEM SIZE IS 7.625KWdc and 6.48KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39203	15041-10000-15895	980 W KNOX ST	90502	15	057B197    25	7351034079	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	33.8541	-118.29383	TI-24 TO AN (E) OFFICE BUILDING. ADDING NEW LIGHTING PANELS TO REMAIN. PC FOR ENERGY ONLY. TOTAL SQ. FT. 9752	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39204	18041-20001-43162	6647 N HAYVENHURST AVE	91406	6	180B137   165	2231008009	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.19165	-118.49259	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.8 kWdc/7.02 kWac-CEC and consists of (1) inverter, (26) modules, (1) back-up battery, (1) transformer, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39205	15041-20000-05830	300 S GRAND AVE 19th Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Issued	03/02/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	Title 24 plan check only.  Total area = 1,338 sq. ft.T.I. to corridor in existing commercial space.  New general and egress lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39206	19041-10000-25101	1812 E 110TH ST	90059	15	088-5A215 476	6069012023	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	33.93511	-118.24028	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39207	13041-20002-21003	2466 E 16TH ST	90021	14	118-5A217 283	5168010007	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.01949	-118.2277	Change to approved set by upgrading a 200-Amp section to 400-Amp, all load remain the same and all changes on this application apply to the core shell only. Future load will apply to different plan check #.(((New 2000 amp commercial building.  Plan check for Energy is on the Main application.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39208	15041-10000-07291	100 S DOHENY DR 1-228	90048	5	138B169   365	4335008***	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.07508	-118.38955	Replacing an existing fire alarm panel  in a high rise building. Scope includes (1) fire alarm panel, (1) power supply and (2) fire alarm device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39209	15041-20000-07078	17302 W OSBORNE ST	91325	12	195B133   132	2768018013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.23324	-118.51172	Plan check for PV system roof mounted system with 36 enphase microinverter 250. Total system size: 9kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39210	16041-10000-33550	11601 W WILSHIRE BLVD 6th FL	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 only in existing high-rise building office. Total area: 7,386 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39211	11041-10000-21966	5815 W SUNSET BLVD 1-90	90028	13	147A191    49	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	34.09822	-118.31613	4 story commercial building, new fire alarm. two panel and 70 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39212	16041-20000-02106	2558 W SAN FERNANDO ROAD	90065	1	150B213   451	5457002013	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.10789	-118.24149	Plan check CHANGE  OF USE FROM WAREHOUSE  TO  ART/ DESIGN STUDIO for Power and energy. Total area: 75,000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39213	12041-20001-17449	18600 W DEVONSHIRE ST Site-Lighting	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.25704	-118.53922	Modification to previously approved set of plans.       <<<Install new panel and circuits for site lighting.  The panel location is in the electrical room of the Use Car Building as shown on page E-2.1.  Plan checked for T-24 energy only.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39214	17041-30000-22678	5453 W BARTON CT	90038	13	144B193  1427	5535006033		Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.08791	-118.31107	Plan check for power and energy. Project scope is (8) single-family homes being fed from a single service as part of a small lot subdivision. Service size is 800-amps. Total lighting area = 6,105 sq. ft.Note: Building permits for the (8) homes have been issued under 16010-10000-04862/04863/04864/04865/04866/04867/04868/04869. Electrical permit fees for the single family homes have been paid for under the respective building permits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39215	13041-20002-35744	8700 W BEVERLY BLVD 1F	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.07666	-118.3805	{{{{{{ 05-21-15 CHANGES TO APPROVED SET OF PLAN. DELTA 3 CHANGES ONLY. UPDATE LIGHT FIXTURES SCHEDULE AND UPDATED LIGHTING AND POWER PLAN, UPDATE TITLE 24 CALCULATION AND PANEL SCHEDULE}}}}}}}[[[[9/10/14  CHANGES TO APPROVED SET OF PLANS. DELTA 2 CHANGES ONLY. CREATION OF AN OFFICE ON THE GROUND FLOOR. ADDITION OF FEW RECPETACLES AND LIGHTING.]]]]]TI 1ST FLOOR. PC for POWER ENERGY GAMMA KNIFE TO MRI. adding 2 UPS as well. Plan checker to verify fees ***ARCHITECTURAL & STRUCTURAL ALTERATION AT THE FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39216	15041-20000-41935	16609 S FIGUEROA ST	90248	15	066B201    17	6121004026	C2-1, R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Apartment			12/14/2015 12:00:00 AM			Reviewed by Supervisor	01/15/2016 12:00:00 AM	ADDRESS	33.88059	-118.28284	Plan check for power and energy. Project site is a new 20-unit aparment building. Work includes a 1200-amp service, (21) panels, associated loads, and (1) elevator. Total lighting area =10,453 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39217	14041-10000-06836	6601 N LAUREL CANYON BLVD	91606	2	180B165   396	2322004073	C2-1L, P-1, P-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1233.01	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.1905	-118.39671	"PLAN CHECK FOR TITLE 24 ENERGY. TENANT IMPROVEMENT OF EXISTING ""SMART & FINAL"" STORE. 1776 SQFT, EMERGENCY LIGHTING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39218	15041-20001-36622	23706 W VICTORY BLVD	91367	3	180B093   851	2033018019	C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.18645	-118.64336	06-15-16 Changes to an approved set of plans. Changes include addition of circuits for fuel dispenser in panel P-C hazardous location. Plan check for hazardous area(boundry of Hazardous location)*****Previous Work Description*****Proposed  984 SF retail & 2,516 SF  convenience store.  Full PC Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39219	18041-10000-01506	7501 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20692	-118.49233	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 126800 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39220	16041-20000-22020	8891 W COLLINGWOOD DR	90069	4	147B169   822	5560038004	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.09599	-118.38461	Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (3) inverters, (61) modules, and (1) load center. Note: Fees are $0 due to senate Bill 12222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39221	19041-20000-05600	1608 W 252ND ST	90710	15	036B193   267	7410020046	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	33.79561	-118.30466	Plan check for a PV1 roof-mounted PV system. System size is 12.9 kWdc/11.324 kWac-CEC and consists of (43) modules, (43) micro-inverters, and (1) load center.$2.23 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39222	15041-10001-22720	1344 W 37TH PL	90007	8	117B197   128	5040011008	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.01982	-118.2988	EXPEDITE PER CUSTOMER REQUESTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.9KW INTERCONNECTED WITH MSP.(18) TRINA SOLAR TSM-250 MODULES(18) ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39223	13041-20000-19124	5736 N ANDASOL AVE	91316	5	174B133   311	2254019027	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Expired	08/13/2015 12:00:00 AM	ADDRESS	34.1748	-118.51109	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.92 KW WITH 16 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39224	15041-20003-24184	8842 W FOOTHILL BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.26086	-118.32514	12/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Service has changed from underground to overhead, and outdoor Title 24 has been revised. 8.2.2017 - Plan check for modification to approved set. Changing from two services to a single 2000A service. Relocating service equipment outdoors. Revise some distribution. Add lighting to tower - update outdoor T24 compliance forms. Add exhaust fans. Layout of rooftop units rearranged. Delta 1 changes.=======Plan check for power and Title-24 (energy).  Total area = 5,249 sq. ft. (indoor) + 1,000 sq. ft. (outdoor)  Core and shell work on existing commercial space.  Two new 480V 3ph-3w services (ungrounded system), new distribution panels, and associated subpanels.  New lighting, HVAC, and other misc loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39225	17041-10000-35813	200 E 9TH ST	90015	14	126A209    89	5145016001	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.04051	-118.25415	CHANGE OF USE FROM RETAIL TO BAKERY-PARIS BAGUETTE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39226	19041-10000-12056	1717 W COLORADO BLVD	90041	14	162A225    80	5669020011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	08/29/2020 12:00:00 AM	ADDRESS	34.13959	-118.20412	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39227	19041-20000-16357	3670 S GLENDON AVE	90034	5	117B161  1210	4252032014	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			05/02/2019 12:00:00 AM			PC Info Complete	05/02/2019 12:00:00 AM	ADDRESS	34.02025	-118.41061	T24 PLAN CHECK ONLY FOR EXISTING APARTMENT BUILDING OUTDOOR POOL AREA. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 7224SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39228	15041-20000-19517	3042 N TREADWELL ST	90065	13	156B209   442	5458006014	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	PIN	34.12041529	-118.2485145	PC FOR 3 NEW TRANSFORMERS FOR FUTURE USE. PC PER APPLICANT REQUEST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39229	13041-10000-13246	11727 W OLYMPIC BLVD	90025	11	123B149   408	4260009017	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	PIN	34.03400974	-118.44875837	Starbucks TI inside a Ralph's supermarket.  Installation of lighting and power.  Title 24 plan check only.  Permit to be issued at electrical plan check counter only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39230	18041-20000-40236	1700 N SILVER LAKE BLVD	90026	13	144A205   215	5423022001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			Reviewed by Supervisor	10/30/2018 12:00:00 AM	ADDRESS	34.08936	-118.26831	PV1.  Install 13.68 kW roof mounted grid tied PV system.  (38) modules with (2) 7.6 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39231	18041-20000-35624	350 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A203 152	5111003039	[Q]M1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	02/11/2020 12:00:00 AM		Permit Closed	08/18/2020 12:00:00 AM	ADDRESS	34.01092	-118.27958	ti to an existing commercial building with service upgrade 5000 amp.  adding new transformers, panels, circuits and backfeeding existing panels.  plan check for power and energy.serice to suppy the following address 4001 S. Broadway.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39232	19041-10000-12121	19216 W SINGING HILLS DR	91326	12	213B117   339	2822012028	A1-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	11/09/2020 12:00:00 AM		Permit Finaled	01/18/2022 12:00:00 AM	ADDRESS	34.27655	-118.55383	Energy plan check for a coutry club TI. Scope includes new lighting and equipment with a total area of 5,890 SQ FT.Bld #: 19014-10000-01694	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39233	13041-10001-34217	510 S BROADWAY	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.04767	-118.25088	01/27/16Changes to an approved set of plans. All changes are clouded. Changes include removing and adding lighting fixtures on lighting floor plan. Note: Permit paid uder PCIS#13041-10001-34217(((((T. I. TO (E) RESTAURANT. TOTAL OCCUPANT LOAD EXCEEDS 100. PLAN CHECK FOR POWER AND ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39234	11041-10001-07707	1800 S FIGUEROA ST	90015	9	124-5A205 147	5126009005	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM			PC Approved	12/16/2011 12:00:00 AM	ADDRESS	34.03562	-118.27103	Modification to a previously approved set of plans.  Change to T-24 only.   PLAN CHECK ONLY for Energy, with Emergency lighting.    <<<<<TENANT IMPROVEMENT  FOR CORPORATE  OFFICES>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39235	12041-10000-03617	234 N LARCHMONT BLVD	90004	4	138B189   501	5515025002	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM			PC Approved	02/21/2012 12:00:00 AM	ADDRESS	34.07571	-118.32343	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT IN EXISTING RETAIL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39236	16041-10000-41487	1150 S OLIVE ST #1350	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.03962	-118.26181	Plan check title 24 only in existing space T.I. in existing space 13th Floor. Total area: 2,220 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39237	13041-10000-07456	18025 W MEDLEY DR	91316	5	165B125   261	2184033006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.14753	-118.52562	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWLELING. TOTAL SYSTEM SIZE 12.48 KW. USING 48 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39238	15041-20000-17842	17544 W SAN JOSE ST	91344	12	207B129   922	2733015014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.26108	-118.51689	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. (30) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39239	13041-10000-20198	1302 W 23RD ST PV1	90007	8	124-5A201 239	5055017028	RD2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.03505	-118.28663	PV1 ROOF MOUNTED SOLAR INSTALLATION, SYSTEM SIZE IS 5.88 KW.  TRANFORMERLESS INVERTER. [MODULES: TRINA SOLAR # TSM-245PC05/PA045.18 |||| INVERTER: SOALREDGE # SE5000AUS]. THIS IS A PLAN CHECK ONLY APPLICATION. ***************************************************************PERMIT SHALL BE ISSUED UNDER APPLICATION #13041-20000-13935 (CLEARANCES ON THIS APPLICATION NUMBER).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39240	16041-20000-29502	17178 W STRAWBERRY DR	91436	5	162B133    54	2292011045	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Expired	10/01/2018 12:00:00 AM	ADDRESS	34.14364	-118.50608	PV1.  Install 7.6 kW AC roof mounted PV system.  Central inverter standard plan.  (32) modules with 7.6 kW transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39241	11041-20000-06676	4221 W WILSHIRE BLVD	90010	4	132B189    20	5504001014	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01, 2127.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.06194	-118.32113	PLAN CHECK 144.9KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39242	19041-10000-13172	713 N VIRGIL AVE	90029	13	141B197   436	5539020030	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.08404	-118.28701	Energy plan check for a change of use from Retail to Bar with new lighting and equipment. Total area cover 860-SQ FT. Per MZ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39243	13041-20000-21167	20954 W VANOWEN ST	91303	3	180B109    15	2148027006	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.19351	-118.59019	Fire Alarm control panel replacement and new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39244	15041-20000-18003	6626 N VENTURA CANYON AVE	91401	2	180B157   364	2329009023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Expired	07/05/2017 12:00:00 AM	ADDRESS	34.19103	-118.42894	PC FOR SFD PV SYSTEM TOTAL OF 7.6KW AC USING CENTRAL INVERTER SYSTEM USING STANDARD PLAN. TOTAL OF 31 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39245	17041-10001-39164	10013 S CENTRAL AVE	90002	8	090B209   258	6049028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	33.94523	-118.25432	Change to approved set by changing the adress and updating existing door on the floor plan. All changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39246	19041-10000-29430	3455 N SCADLOCK LANE	91403	4	159B145   244	2279030008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.13408	-118.47084	PLAN CHECK FOR PV ROOF MOUNTED 21.66 KW DC/18.24 PV1 SYSTEM CONSISTING OF 76 MODULES(HANWHA PLUS BFR-285) WITH 76 MICROINVERTERS(IQ7-60-2-US) CONNECTED TO A 125A DISTRIBUTION PANEL CONNECTED TO EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39247	17041-30000-43722	13488 W MAXELLA AVE	90292	11	105B153    77	4212004032		West Los Angeles				2753.02	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	33.98592	-118.44252	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,826 sq. ft.Note: Building application has been generated under 17016-30000-35358	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39248	14041-20000-01678	2817 E CESAR E CHAVEZ AVE	90033	14	127-5A225 102	5178019004	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.04431	-118.20175	T24 FOR EXISTING LAUDRY MAT. SCOPE OF WORK IN WAITING AREA ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39249	13041-10001-29544	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			PC Approved	05/02/2014 12:00:00 AM	ADDRESS	34.03497	-118.45709	((PLAN CHECK ONLY APPLICATION. RELOCATION FACP))Installation of a new fire alarm system and to provide 24-hour system monitoring to sprinkler system.  Single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39250	19041-10000-50047	1100 W WILSHIRE BLVD #500	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/15/2020 12:00:00 AM		Permit Finaled	11/29/2021 12:00:00 AM	ADDRESS	34.05228	-118.26384	FIRST TIME TENANT IN SUITE #500 ON THE 2ND FLOOR OF A HIGH RISE BULDING. INSTALLING NEW PANELS, TRANSFORMER, CIRCUITS, LIGHTS, ETC. FULL PLAN CHECK FOR POWER & ENERGY.  AFFECTED AREA: 3,195 SFTBldg Permit: 19016-10000-38907	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39251	14041-20001-20609	1636 W 8TH ST	90017	1	130-5A205 112	5142017021	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.05263	-118.27317	PV2.  Install 81.0 kW roof-mounted, utility-interactive PV system.  (9) Power One PVI-8.6-TL-OUTD-US-A transformerless inverters w/ DC AFCI protection.  324 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39252	19041-10000-32622	6259 W 87TH ST	90045	11	096B165   718	4123003027	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/29/2023 12:00:00 AM	ADDRESS	33.95867	-118.39463	FULL FOR POWER AND ENERGY. FIRST TIME TENANT FOR A RETAIL BOOKSTORE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3126 SQ. FT. B#19016-10000-07194	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39253	11041-20000-08825	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			Verifications in Progress	09/19/2011 12:00:00 AM	ADDRESS	34.30363	-118.45814	Plan check power and energy for existing warehouse with two existing services. New circuits, panels, and equipment added. Plan check to replace 1200A service and switchboard under #11041-20000-00573.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39254	13041-10012-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta 32 revisions:  REPLACED 2EA 40KVA UPS SYSTEMS WITH ONE 120KVA SYSTEM;ALL CHANGES ARE CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39255	18041-10000-13079	1133 S FLOWER ST TOWER 2	90071	14	127-5A207 344	5138015045	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			07/05/2018 12:00:00 AM			Reviewed by Supervisor	07/19/2018 12:00:00 AM	PIN	34.04253434	-118.26540471	[2 OF 3]  Changes to approved set (Refer to plan check# 15041-10004-26464), Plan check fee for Tower 2 is paid under the Podium plan check fee. Only one set of plan is provided for Tower 2, Tower 3, and Podium under this SOW. Master plan #15041-10004-26464 and narrative of changes are attached to this submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39256	11041-10003-16708	147 N WESTERN AVE	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.07441	-118.30931	NEW 800A SERVICE AND CIRCUITS FOR A GROUP OF 6 COMMERCIAL BUILDINGS.  MAIN SERVICE IS IN BUILDING 4558 W. COUNCIL ST.  OTHER BUILDINGS (4556 W. COUNCIL AVE.,     143 N. WESTERN AVE,      149 N. WESTERN AVE,    151 N. WESTERN AVE.) WILL BE ON SUPPLEMENTAL PERMITS TO THIS.     THIS APPLICATION IS FOR 147 N. WESTERN AVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39257	11041-10001-02160	1642 E 41ST ST	90011	9	114A213    57	5116013004	M1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM			PC Approved	06/01/2011 12:00:00 AM	ADDRESS	34.00802	-118.24438	Ti in an existing retail. EPC is for T24. (Permit was issued under 11041-10001-02160)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39258	17041-10001-25633	360 E 2ND ST 2ND FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED ON PLANS. CHANGE TO LIGHTING FIXTURE TYPE. UPDATED SCHEDULE AND T24 DOCUMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39259	10041-10000-10598	310 W WASHINGTON BLVD	90292	11	105A147   253		C2-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM			PC Info Complete	07/02/2010 12:00:00 AM	PIN	33.98038877	-118.46355239	CONSTRUCTION  0F 8 TOWNHOUSE BUILDINGS : BLDGS 1THRU BLDG 4 EACH HAS 7 UNITS; BLDG 5 THRU BLDG 7 EACH HAVE 6 UNITS AND BLDG  8 HAS 4 UNITS FOR A TOTAL OF 50 UNITS EACH  UNIT IS 2-LEVELS OVER GARAGE . SWBD IS EXISTING AND PERMIT FINALED ON 05041-20000-24088	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39260	15041-10000-02925	9760 W PICO BLVD	90035	5	129B165  1239	4307004***	C4-1VL-O, R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.05401	-118.40151	Plan check for power and energy.  School with gym expansion	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39261	10041-10000-02868	14006 W RIVERSIDE DR # 218	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	08/10/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	TI  REMODEL OF  (E)  RETAIL SPACE  INCL.: PARTITIONS, DOORS, CEILING, FITTING RMS, LIGHTING, ETCPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39262	13041-10001-12614	9040 W PICO BLVD	90035	5	132B169   879	4305007029	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.05505	-118.38885	Change to approved set by adding (3) circuits on panel-P. All changes are under delta-5 only.(((pc for power and energy. CHANGE OF USE FROM EXISTING ONE STORY FURNITURE BUILDING TO AN ORTHODOX SYNAGOGUE INCLUDING PARTIAL DEMO  15215 SF)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39263	10041-20000-20797	11541 N BLUCHER ST bldg6	91344	12	213B145    79	2605002012	QC1-1VL, QP-1VL	North Valley	Granada Hills - Knollwood		YES	1092.00	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	PIN	34.27943684	-118.47043731	Permit expired (BLDG. 6).  EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39264	18041-10000-23857	1127 S SPAULDING AVE	90019	10	132B177  1059	5086026017	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			06/26/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.05541	-118.36046	NEW 4 STORY, 13 UNITS APARTMENT BUILDING WITH SUBTERRANEAN GARAGE. (7 Typ Floor Plans) Bldg Permit: 16010-10000-02146	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39265	14041-20001-07530	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM			PC Approved	01/16/2015 12:00:00 AM	ADDRESS	33.97749	-118.41246	[1/16/15 CHANGES TO APPROVED SET OF PLANS. PLANCHECK PER INSPECTOR REQUEST. VOLTAGE DROPS AND CHANGES TO ELEVATOR AND FREIGHT ELECATORCHANGES ARE CLOUDED.]]LARGE TI FOR EXISTING OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39266	11041-10001-01055	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM			PC Approved	12/01/2011 12:00:00 AM	ADDRESS	34.0965	-118.30717	New generator and transfer switch for an existing office building.  EPC for Power.  The neutral untied from ground. and rating of all three xfer switches aic  changed from 65k to 42 k.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39267	10041-20000-02550	14655 W BLYTHE ST 1-69	91402	6	189B149   325	2210020002	R3-1	North Valley	Mission Hills - Panorama City - North Hills			1200.30	Electrical	Electrical	Apartment			02/12/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.21532	-118.45271	69 UNITS APARTMENT BUILDINGRequest for Modification to separate Fire Alarm system filed .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39268	11041-10000-16626	6263 N TOPANGA CANYON BLVD	91367	3	177B101    20	2146001025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM			Verifications in Progress	09/28/2011 12:00:00 AM	ADDRESS	34.18482	-118.60621	TI TO A RETAIL STORE.  PLAN CHECK IS FOR POWER AND ENERGY.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39269	16041-30000-23411	17456 W LEMAC ST	91325	3	189B129  1196	2202006001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.21102	-118.51394	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39270	14041-10001-11744	1616 N LA BREA AVE	90028	13	147B181   377	5548012046	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.1002	-118.34456	8/10/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA F. ADDING (2) NEW MOTORS.[[5/2/2014- PLANS EXPIRED IN 2010, USE 2008 CODE CYCLE FOR PLAN CHECK. EXPIRED PLAN CHECK ON APPL#:09041-10000-17341]] New 56-unit, 4 sotry mixed-use building.  Power and energy.  A variance has been filed to separate the fire alarm plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39271	12041-10000-02082	1555 S CARDIFF AVE	90035	5	129B169   569	4306017023	R1-1	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.05082	-118.3922	New 7.76 kw rooftop mounted photovoltaic system for an existing single family residence.  <<This application is to replace the App# 12041-10000-02061 that was canceled by the cashier.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39272	17041-10003-40645	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Closed	09/17/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	DELTA 5 and 6 CHANGES TO APPROVED SET OF  PLANS.  Install (4) new state approved  2-story press box directly fed by Skid # 2, 3, 6 ,and 7.Building application #: 18010-10000-01334  18010-10000-01335  18010-10000-01336                                          18010-10000-01337<<<<Plan check for Power only, TEMPORARY POWER for the Coliseum. Add (N) 2000A 480/277V dist. board to the existing 5000A service, (7) temp. power panelboards, (3) tower cranes.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39273	16041-30000-20338	422 S LAKE ST	90057	1	135A203   398	5154030019	(T)R4P-2	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Apartment			06/09/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.06229	-118.27435	NEW FIRE ALARM SYSTEM 200 DEVICES AND 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39274	12041-20000-05444	801 N FAIRFAX AVE Space 101&-102	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1920.00, 1944.00	Electrical	Electrical	Commercial			03/09/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	ADDRESS	34.08567	-118.36172	Revisions to 11041-20000-26092	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39275	13041-10000-05019	3349 S OAKHURST AVE	90034	10	123B165  1176	4311016010	R1-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2013 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.02996	-118.39774	PV1 2.16 KW {10 MODULES: REC 245 PE BLK} {MICROINVERTER: ENPHASE M215-60-2LL-S22}2 STORY HOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39276	14041-20000-10419	515 S FIGUEROA ST 4TH FLR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	APPROX 20,000 SF OFFIce. TENANT IMPROVEMENT FOR THE ENTIRE  4TH FLOOR. new lighting.pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39277	17041-20000-25650	7675 N SAN FERNANDO ROAD	91505	2	186B177   564	2466036***	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.20826	-118.35549	ti to an existing commercial building.  adding new lighting new controls to new panel, newly connected load < 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39278	19041-20000-01990	8121 N FAIRCHILD AVE	91306	3	189B109   111	2108030003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.21756	-118.58784	addition of (2) tesla batteries 5KW each to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39279	14041-20000-15429	7633 N CARMENITA LANE	91304	12	189B089   426	2017028036	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.21077	-118.65566	PV1 SINGLE FAMILY. TRANSFORMERLESS INVERTERS. 2 INVERTERS TOTAL. USING STANDARD PLAN. TOTAL SYSTEM SIZE 9KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39280	18041-10001-28971	9223 N OWENSMOUTH AVE	91311	12	198B105   134	2746012039	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Approved	10/16/2018 12:00:00 AM	ADDRESS	34.238	-118.60204	Expedite ApplicationNew Rooftop solar system (PV2) on a commercial building. System size 502.2 kW DC/ 449.323 kW AC CEC/ 400 kW AC. (1395) modules, with P730 power optimizer. (4) central string inverter at 100kW each. System interconnect to New 600A service, 480/277 V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39281	13041-10000-19072	8735 N TAMPA AVE	91324	12	195B117   167	2783027029	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.2293	-118.55375	NEW 600A SERVICE AND SWITCHBOARD , 3 PHASE 4 WIRE DELTAAT A BAKERY LOCATION. PLAN CHECK IS FOR POWER AND ENERGY AND EMERGENCY LIGHTING IN A SINGLE-STORY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39282	11041-10000-00601	732 E 10TH ST Unit 104	90021	9	124-5A211 354			Central				2260.00	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.03504	-118.25099	Plan check for electrical and T-24 for space 104.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39283	16041-10000-22136	330 S ALAMEDA ST #B	90013	14	127-5A215 134	5163010007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.04394	-118.23787	PC for T-24 only: Remove HID fixtures and replace with new LED fixtures. Total area: 13,856 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39284	19041-20000-20022	4854 N VAN NUYS BLVD	91403	4	169-5A151 107	2248006002	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.15917	-118.4485	ti to an existing commercial building.  adding new lighting to existing panels.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39285	19041-10000-52483	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.03145	-118.41085	"REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFITS KITS. INDOOR ""TRAINING &TESTING BLDG"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39286	17041-20000-28364	15060 W VENTURA BLVD 1st Floor	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.15287	-118.46147	Plan check for Title 24 only. Project site is an elevator lobby in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 937 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39287	14041-20000-08546	6116 N CAPISTRANO AVE	91367	3	177B101    96	2039029026	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.18144	-118.6172	PV1 7.25KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US, SOLAREDGE SE3000A-US}]. [(29)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39288	13041-10000-34921	400 S WESTERN AVE # 101	90020	10	135B193   439	5503014023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.067	-118.30888	"plan chk is for title 24 onlyCOFFEE SHOP TI IN EXISTING RESTAURANT OF 1,177 SQ.FT. IRREGULAR 63'-0"" X 21'-4"" SUITE 101."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39289	14041-10000-12589	1235 E OLYMPIC BLVD	90021	14	123A213     9	5146018003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.03294	-118.24497	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 11218 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39290	12041-10003-25454	888 S OLIVE ST	90014	14	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			12/17/2015 12:00:00 AM	04/18/2016 12:00:00 AM		Issued	04/18/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE 2 STORY PENTHOUSE. RELOCATION OF HEAT PUMPS TO NEW 480V PANEL. ALL CHANGED CLOUDED DELTA 4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39291	12041-20000-26799	2844 W ROWENA AVE Lot 4	90039		151-5A207 173	5434033010					YES		Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM			Reviewed by Supervisor	11/27/2012 12:00:00 AM	ADDRESS	34.10762	-118.26616	Enphase system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39292	14041-10000-00677	635 W DOWNEY WAY	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles		Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.01874	-118.28387	Install fire alarm for a 5 story building for USC university (VPD - Dr. Verna and Peter Dauterive Hall).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39293	16041-10000-22685	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC FOR ENERGY. TENANT IMPROVEMENT: CONVERT  EXISTING RESTAURANT SPACE  TO OFFICE SPACE. TOTAL AREA 2800 SQ FT.B#16016-10000-13492.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39294	12041-10000-09027	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALL A NEW SHELTERIN TESORO REFINARY FOR A NEW GAS EMISSION ANALYZER IN A CLASS I DIV 2 AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39295	10041-20000-10595	516 N BEAUDRY AVE	90012	1	135A211   112	5405032003	[Q]C1.5-2	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Historic Cultural	YES	1976.00	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	08/25/2010 12:00:00 AM	ADDRESS	34.06468	-118.24952	energy plan check jack in the box	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39296	15041-20002-23696	15760 W STRATHERN ST Bldg. 1	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM	ADDRESS	34.21559	-118.47701	(12/7/2016)CHANGES TO AN APPROVED SET OF PLANS TO REFLECT FIELD CONDITIONS.THIS IS PLAN CHECK ONLY.Plan check for power and energy.  Total area = 21,532 sq. ft. (indoor) + 6,632 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39297	12041-10000-15564	13410 N ELDRIDGE AVE	91342	7	225B157   226	2511026014	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2012 12:00:00 AM	08/08/2012 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.31586	-118.42166	Plan check for PV for an existing Single family dwelling. Roof mounted. 5.61kW DC.  System is negatively grounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39298	16041-20000-11410	6921 N ORION AVE	91406	6	183B145   529	2234003007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.19634	-118.47069	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (31) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39299	14041-20000-22147	13636 W LEMAY ST	91401	2	180B157   221	2329001045	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.1925	-118.43018	4.29KW PV1 roof-mounted system including (18) SolarWorld SW275 modules and Enphse M250 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39300	14041-10000-24863	21606 W VENTURA BLVD	91364	3	171B105    55	2168023067	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.16805	-118.60003	Title 24 plan check for a bakery store. Total area 980 sq ft.  Work area: Entrance and  sales area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39301	15041-20002-01340	21040 W CALIFA ST SUITE A	91367	3	174B105     8	2149002021	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.17715	-118.59163	"10.21.2015 - Changes to approved set of plans. Plan check for Delta 2 and Delta 4 changes only. Relocate electrical room, add light fixtures, and other misc. changes.Note: Plan was restamped by Steve Montes for application #15041-20001-01340 to have one complete plan set with all delta changes approved.*****Previous Work Description*****10/20/2015 Changes to an approved set of plans. Plan check for Delta 5 changes only. Changes includes the addition of a lockable, fused disconnect switch to the secondary of transformer ""T-2"", and the removal of the main of panel ""DL"". Other Deltas (2 and 4) are not included in this plan check.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE OF FROM OFFICE TO DIALYSIS CLINIC. PC FOR MEDICAL PER ARTICLE 517. NO CRITICAL CARE AREAS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39302	14041-10000-16802	8458 N WYSTONE AVE	91324	12	192B121   322	2784012005	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.22436	-118.54685	Install roof mounted solar PV system.  Total system size = 5.9 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39303	19041-10000-16376	10888 W LA TUNA CANYON ROAD	91352	6	195B173    58	2408005038	(Q)M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.23418	-118.3683	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39304	11041-10000-19400	3933 S HILL ST 2ND FL	90037	9	115-5A203  29	5122046026	[T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Expired	10/07/2013 12:00:00 AM	ADDRESS	34.01227	-118.27983	ADDITION TO EXISTING OFFICE SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39305	13041-10000-12540	111 E UNIVERSAL HOLLYWOOD DR 7TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVEMENT ON THE 6TH FLOOR OF AN OFFICE HIGH RISE BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39306	16041-10000-38868	15503 W VENTURA BLVD suite 150	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.15504	-118.4723	Full plan check for a medical office located in the first floor of a three-story commercial building.Scope covers half size of the floor with new lighting, receptacles and equipment;  Total area is 11,667 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39307	15041-10000-17982	2753 W WAVERLY DR BLDG 11	90039	4	151-5A207 233	5438025***	RD2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.10855	-118.26334	NEW DEVELOPMENT FOR MULTI BUILDING TOWNHOUSES 600 AMP SERVICE.  THIS IS BUILDING 5 OF 5.  PLAN CHECK FOR POWER AND ENERGY.  EACH BUILDING HAS ITS OWN SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39308	16041-20001-35866	6922 W HOLLYWOOD BLVD #200	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.10137	-118.34103	11/01/2016 Plan check for Title 24 only. Project site is a room on the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 316 sq. ft.*****Previous Work Description*****TENANT IMPROVEMENT -  OUTLETS AND SWITCHES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39309	17041-20001-30984	22111 W CAJUN CT	91303	3	183B101   867	2024012***	(T)(Q)RD2-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			Reviewed by Supervisor	09/07/2017 12:00:00 AM	ADDRESS	34.2001	-118.60859	expeditepv1install roof mounted pv system sized 6kw interconnected with msp.  center fed panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39310	17041-10000-07167	411 S NORMANDIE AVE	90020	10	135B193   636	5502016007	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			03/14/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	01/19/2021 12:00:00 AM	ADDRESS	34.06672	-118.30068	PC FOR POWER AND ENERGY. CONSTRUCTION OF A NEW 7 STORY 224 UNIT APARTMENT BUILDING WITH PARKING AT GROUND LEVEL AND 3 SUBTERRANEAN LEVELS. SERVICE 3000A. TOTAL AREA 201245 SQ FT.ACCORDING TO THE BUILDING DEPARTMENT VARIANCE HAS BEEN FILED AS A LOW RISE BUILDING, FIRE ALARM HAS TO BE FILE SEPERATELY.B# 16010-10000-01635.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39311	15041-20001-43670	4860 W SANTA MONICA BLVD	90029	13	144B197   760	5538019001	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM			PC Approved	04/03/2017 12:00:00 AM	ADDRESS	34.09071	-118.29546	changes to an approved set of plans.  changes include diffrent light fixtures and quanties delta 1 indoor lighting only.  plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39312	12041-10000-23909	1823 N DOHENY DR	90069	4	150B169  1247	5561008026	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2012 12:00:00 AM			PC Info Complete	10/23/2012 12:00:00 AM	ADDRESS	34.10497	-118.38828	This is single story SFD, XFMRless by sma ul listed. 1  10KW inverter , 42 modules, 1 combiner, 60 amps disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39313	13041-10000-19290	1808 S MANTIS AVE	90732	15	012B189   169	7562010014	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	33.72855	-118.31417	PV1 9kw Xfmr AND XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [ 2 INV: PVI-3.6-OUTD-S-US (transformerless) and PVI-4.6-I-OUTD-X-US-Y (isolated)] [ 36 MOD: TRINA {TSM-250PA05.08}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39314	14041-10000-32914	3413 N ADINA DR	90068	4	159B177   750	2427001015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM			Not Ready to Issue	12/26/2014 12:00:00 AM	ADDRESS	34.12827	-118.35313	Plan check for a roof-mounted PV system on a residential space. System size is 7.2 kWac and consists of (35) modules and (2) 3.6 kW inverters.  New main circuit breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39315	18041-10000-41733	1901 S CREST DR	90034	5	126B169    95	4302007001	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.045	-118.38825	NO PERMIT FEE DUE TO AB1414.  Plan check for a PV1 8.4KW AC/ 10.4KW DC roof-mounted solar PV system with (32) modules, (2) inverters, (2) subpanels, and (2) energy storage system interconnecting through the main service.Note. Portion of the permit fee is paid under 18041-90000-33282.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39316	13041-10000-33955	1230 S SANTEE ST	90015	14	124-5A209 136	5145027039	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.03552	-118.25778	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING. REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH ENW FLUORESCENT FIXTURES. PROJECTED AREA ANTICIPATED IN SCOPE OF WORK IS TO BE 468 SQ FT. REPLACING (3) FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39317	13041-10000-29352	13274 W FIJI WAY 1-6 floors	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	33.97902	-118.43558	13041-10000-29352PC FOR ENERGY. TI (E) BLDG FLOORS 1-6 BATHROOMS. installing lights on existing branch circuits. less than 400A per applicant. emergency lights added. inspector to verify if high rise and if multi-level occupancy sensor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39318	13041-10000-27438	990 W KNOX ST	90502	15	057B197    25	7351034079	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	33.85405	-118.29333	remodel office space/room.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39319	19041-10000-24342	248 S MAIN ST 1ST FLR	90291	11	111B141   614	4286003020	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	33.99669	-118.47804	Energy plan check for an office T.I located in a single story building. Scope includes a portion of the lighting T.I  on the lighting floor plan with new switches.(((FOR COMMERCIAL TENANT IMPROVEMENT. NEW FLOOR AND WALL FINISHES, PARTITION WORK, DOOR REPLACEMENT, AND MINOR ELECTRICAL WORK. THE SCOPE OF WORK IS LIMITED TO A 6,687 SF AREA IN AN EXISTING 9,516 SF OFFICE BLDG. NO EXTERIOR CHANGES, ADDDED AREA OR CHANGE OF USE. ***NO EXTERIOR WORK***)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39320	16041-20000-36295	7154 N RESEDA BLVD	91335	3	183B125   230	2125001022	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.20085	-118.53586	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR DISCOUNT AUTO PARTS. 4859 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39321	17041-10000-44638	3315 W 41ST ST	90008	10	114B185   300	5024028027	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.01015	-118.33021	Plan check for PV roof mounted system with battery backup . PV System size: 7.6kW AC with 13 modules and 1 inverter(7.6kW) and 1 LG battery 5.0kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39322	18041-10000-48784	3240 S SHASTA CIR SOUTH	90065	14	159A217   274	5678022003	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.12909	-118.23399	PLAN CHECK FOR ROOFTOP MOUNTED 5.04 kwdc and 3.84 kwAC PV SYSTEM WITH (16) MODULES AND POWER OPTIMIZER P320, (1) AC INVERTER WITH 3.8 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39323	18041-20000-19580	555 W 5TH ST 17th Floor	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check for Title 24 Energy only in existing high rise building conver an existing conference room to 3 offices and corridor. Total area: 720 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39324	19041-10000-53082	10801 W CHANDLER BLVD	91601	2	174B173  1312	2416015900	PF-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	06/26/2020 12:00:00 AM		Permit Finaled	12/30/2022 12:00:00 AM	ADDRESS	34.16881	-118.36593	PC FOR A FIRE ALRAM SYSTEM. 1 FIRE ALARM PANEL AND 84 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39325	18041-20001-24218	1701 W SLAUSON AVE	90047	8	108B193  1251	5003035018	[Q]MR1-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM			PC Approved	09/14/2018 12:00:00 AM	ADDRESS	33.98927	-118.30676	Expedited plan check fee. PV2.  Installation of a 72 kW rooftop grid-tied PV system.  (180) modules with (2) 28 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39326	14041-20000-23467	920 W DOWNEY WAY suite 102	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			PC Approved	08/27/2014 12:00:00 AM	ADDRESS	34.02063	-118.28879	Plan check for energy only. Office T.I. 1122sqft. Demo existing lights and install new lighting (incl. emergency). New controlled receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39327	12041-20000-25686	11111 W SANTA MONICA BLVD # 1470	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	Install lighting and power for the TENANT IMPROVEMENT TO EXISTING OFFICE SUITE #1470: REMOVE DEMISING AND COMBINE OFFICES, NON-BEARING PARITIONS, MILLWORKS AND SUSPENDED CEILING (3,415 SQ FT). Plan check for T24 lighting and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39328	13041-10000-20080	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.94955	-118.38214	Plan check for medium voltage unit substation to supply portable air cooled chiller.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39329	12041-10000-01919	8525 N HANNA AVE	91304	12	192B101   169	2010014017	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	01/27/2012 12:00:00 AM	ADDRESS	34.22502	-118.60738	New 6.84 rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39330	14041-20000-07630	6900 N WINNETKA AVE	91306	3	183B113   690	2135030006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.19574	-118.57078	PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39331	18041-20000-40719	4707 N COLUMBUS AVE	91403	4	168B145   660	2264005026	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.15599	-118.46397	permit fee $0.00 by state senate bill no. 1222pv1install roof mounted v system sized 15.2KW aC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39332	14041-20001-04129	17737 W ALONZO PL PV1	91316	5	168B129   745	2182025012	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.15277	-118.51955	][] EXPEDITED PER APPLICANT REQUEST ][]PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 400A MAIN SERVICE PNL. UNGROUNDED SYSTEM, SIZED @ 9 kW DC, WITH (36) CANADIAN SOLAR #CS6P-250PX,  (36) OP300 OPTIMIZERS, (2) SOLAREDGE SE3800-US-ZB-U, (1) 125A LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39333	15041-20000-14185	6320 N TOPANGA CANYON BLVD G-1675	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title 24.  Total area = 3,609 sq. ft.  T.I. to commercial first time tenant.  Two new panels with a step-down transformer.  Lighting and recepticles.m.frederick	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39334	17041-10000-35422	18042 W ERWIN ST	91316	5	177B125  1003	2123023093	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.18376	-118.52636	Install new rooftop solar system on an SFD, 3.8 kW AC, (14) modules with (14) optimizers, (1) inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39335	13041-10000-07302	6133 N KENTLAND AVE	91367	3	177B097   322	2039029013	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.18233	-118.61809	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.3 KW. USING 38 MODULES, TRANSFORERMERLESS INVERTER, NONSTANDARD PLAN. 2 INVERTERS, LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39336	17041-20001-18550	21004 W BALTAR ST	91304	3	189B109   263	2109009023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			PC Approved	06/16/2017 12:00:00 AM	ADDRESS	34.21662	-118.59082	expeditepv1install roof mounted pv system sized 11.3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39337	18041-20000-30976	19929 W RINALDI ST #130	91326	12	213B113   302	2701040036	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Issued	08/15/2018 12:00:00 AM	ADDRESS	34.27592	-118.56887	ti to an existingcommercial building.  alteration with 50% light reduction.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39338	13041-10001-24641	19411 W CYPRESS POINT DR	91326	12	213B117    66	2822024025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.28349	-118.55658	][][EXPEDITED PER APPLICANT REQUEST][][][PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE FAMILY DWELLING (NON STANDARD PLAN) SYSTEM SIZE IS 4.72 KW AC AND 5.5 KW DC. [MODULE: ND-250QCS |||| MICROINVERTER: ENPHASE # M215]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39339	16041-20001-26079	13661 W CHASE ST	91331	6	195B157   565	2640026002	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	34.23096	-118.42994	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 3.0kW with 12 modules and 1 inverter(3.0)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39340	17041-10002-35365	250 N BURLINGTON AVE	90026	13	136-5A207 263	5159009008	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			PC Approved	06/20/2018 12:00:00 AM	ADDRESS	34.06744	-118.26543	Design change on permit# 17041-10000-35365. (54) modules, (1) SE11400A-US, (1) SE6000H-US on existing 600A, 120/240 V, 1ph, 3W service.**Zero fee per Senate Bill 1222**<<<PC for rooftop solar for apartment building. Installing 70 new PV modules with optimizer and one SE9.0KUS inverter. Total system size is 9kW.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39341	19041-20000-53111	23443 W STRATHERN ST	91304	12	189B093   247	2020017054	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.21524	-118.63788	PV1. INSTALL 11.22 KW DC ROOFMOUNTED PV SYSTEM WITH (34) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39342	19041-20001-42308	20159 W HATTERAS ST	91367	3	174B113   127	2151008058	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM			PC Approved	10/23/2019 12:00:00 AM	ADDRESS	34.17582	-118.57294	Relocation of inverter and AC disconnect. $0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39343	14041-10000-32528	5530 E VALLEY BLVD	90032	14	138A237    30	5221013038	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.07423	-118.16225	T.I to a design set with new load for gas dispensers connecting to circuit from previous design set.Note: previous design set (14041-10000-19956) is plan checked under Mehdi.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39344	14041-20000-16744	11315 N HUNNEWELL AVE	91342	7	210B169    58	2530006008	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.08	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.27594	-118.39227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39345	11041-10002-14179	8417 W 3RD ST	90048	5	138B173   737	5511014017	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM			PC Approved	01/24/2013 12:00:00 AM	ADDRESS	34.07321	-118.37368	(((( 1/24/2013 Removed chandelier and replaced 6 of the lighting fixtures (1h, 1i, 1f, 1g, 1d, 1e)  with LED fixtures. 518 sqrft. single story. Did not alter the power plan.)))))T.I.  Office space being converted to beauty salon.  This is a single story building.  Change of use.  Plan check is for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39346	15041-20000-42409	500 S FIGUEROA ST LEVEL B	90071	14	130-5A209 117	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.05146	-118.25758	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON LEVEL B (CONFERENCE ROOM). SCOPE INCLUDES RELOCATING THREE LIGHTING FIXTURES. TOTAL AREA IS 1780 SQ. FT. NOTE: PERMIT PAID UNDER PCIS#15041-20000-30284 / PCAM#X15VN17883	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39347	13041-10000-28327	1051-1055 N WESTERN AVE	90038	13	144B193   881	5536019031	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	PIN	34.08976899	-118.30945439	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALL NEW FLUORESCENT FIXTURES. 5225 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39348	15041-20000-18386	1522 S WESTGATE AVE	90025	11	126B149   563	4262005027	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			06/12/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.04171	-118.45842	NEW 3 STORY APARTMENT. TOTAL OF 9 UNITS. PARKING GARAGE. PC FOR POWER AND ENERGY. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39349	15041-20000-38571	20754 W LUGANO WAY	91326	12	213B109   283	2701065001	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Expired	01/22/2018 12:00:00 AM	ADDRESS	34.27826	-118.58526	PV1.  Plan check for PV roof mounted system. System size: 10.0kW with 46 modules and 1 inverter(10.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39350	10041-10000-25830	3976 W MARTIN LUTHER KING, JR BLVD UNIT#3	90008	10	117B181   606	5032007022	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	12/30/2010 12:00:00 AM	PIN	34.01494886	-118.34261888	REPLACE/INSTALL LIGHTS, SWITCHES,  TO AN EXISTING CIRCUITS. EPC IS FOR ENERGY, T24 & EMERGENCY LIGHTS. UNIT#3OF 4 (PERMIT WAS PULLED UNDER# 10041-10000-23248)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39351	16041-10000-30223	14006 W RIVERSIDE DR FC-03	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	TI TO (E) RESTAURANT CONSTUCT NONBEARING WALLS AND INSTALL NEW SERVICE COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39352	18041-10000-37423	2883 E PICO BLVD	90023	14	118-5A221  44	5169008902	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	34.01942	-118.2171	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39353	15041-10000-03110	12850 W MONTAGUE ST	91331	7	201B161   690	2624013005	RA-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.24662	-118.41241	PV1, 5KW AC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE,.(16)  MODULES SUNPOWER SPR-327NE-WHT-D (1) INVERTER SMA AMERICA SB 5000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39354	11041-10000-20586	1900 N HIGHLAND AVE	90068	4	150A185   217	5575024017	[Q]C2-1VL-SN	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.10562	-118.33728	T.I. for an existing Subway restaurant.  PLAN CHECK ONLY for Energy, all Emergency lighting is Existing per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39355	12041-20000-07096	6828 N VAN NUYS BLVD	91405	6	183B149   704	2217009016	(Q)RAS4-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Apartment			03/28/2012 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.19475	-118.44846	Revisions to approved set of plan 10041-20000-12992 : Change of sevice, adding new service, adding panel for new Laundry roomNEW MIX USE 68 UNIT APT BLDG plans expired and changed it droped from 96 units to 68 all remaining units still the same all common area are the same no change feeders panel schedules are the same service partially changed building plan check changed the fee to about 50% of original fees therfore using the same old plans a reduction of fee is giving similar to building plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39356	15041-10000-14904	1050 S GRAND AVE	90015	14	127-5A207 294	5139010013	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.04171	-118.26155	PC FOR POWER AND ENERGY. NEW HIGH RISE, MIXED USED BUILDING, WITH 22 STORIES AND 151 UNITS AND 10 TYPES APARTMENTS. TOTAL AREA 38813 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39357	15041-10000-38103	17517 W CHATSWORTH ST	91344	12	207B129   411	2712027036	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.2651	-118.51602	PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO BAKERY. TOTAL AREA 1042 SQ FT. NEW 400A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39358	13041-20006-35598	11985 W BLUFF CREEK DR BLDG #3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM			PC Approved	05/01/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	Changes to approved set (13041-20004-35598).  Changes to AIC rating of electrical distribution equipment.  New Isc is lower based on calculations that include feeders between main serviceboard and individual building switchgear.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39359	09041-10001-23338	1508 S FEDERAL AVE	90025		126B149   101	4261001017	R3-1/C2-1VL		West Los Angeles	West Los Angeles			Electrical	Electrical	Apartment			03/22/2010 12:00:00 AM			PC Info Complete	03/22/2010 12:00:00 AM	ADDRESS	34.04535	-118.45436	NEW MIXED USE 5-STORY  63UNITS APARTMENT WITH GROUND FLOOR RETAIL AND 2 LEVELS OF UNDER-GROUND PARKING PER ZONE VARIANCE . NOT: PLAN CHK FEE  IS TO BE RECALCULATED AS FEES WERE DETERMINED FROM OLD FEE SCHEDULE. ALSO, VARIANCE HAS TO BE FILED FOR SEPARATION OF FA PLANS minor change to single line diagram. increased two elevators from 30 to 40 hp. gym/ rec unit from house to residential panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39360	16041-10000-43717	1750 N GLENDALE BLVD	90026	13	144A209   317	5423005004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			12/22/2016 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/09/2023 12:00:00 AM	ADDRESS	34.08713	-118.25942	PC for new five story apartment with 70 units with two levels of subtarrenean basement.  PC for new 3000 A120/208 service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39361	11041-10000-27489	9615 N AQUEDUCT AVE	91343	12	201B141   410	2671008032	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	05/15/2012 12:00:00 AM	ADDRESS	34.24497	-118.47406	14.1KW roof mounted Photovoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39362	18041-20000-36702	7033 N RESEDA BLVD	91335	3	183B125   454	2126008009	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.19864	-118.53624	pv2install roof mounted pv system sized 14KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39363	13041-10000-24613	5415 S CENTRAL AVE 101-102	90011	9	108B209   707	5103020013	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	33.99296	-118.25677	PERMIT FOR NEW 200 SERVICE, 5 PANELS 40 BRANCH CIRCUITS. MIXED USE BUILDING. ******************************************************PLAN CHECK FOR TITLE 24 PART 6 ENERGY.  LOAD LESS THAN 400 A, 773 SQ FT, NOT A METHANE ZONE.  SERVICE SIZE IS 200A. FULL PLAN CHECK SUBJECT TO INSPECTION (TENANT LEASE SPACE).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39364	17041-20001-29091	8338 S LINCOLN BLVD	90045	11	096B157   258	4113016019	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	ADDRESS	33.96183	-118.42074	1/12/2018changes to an approved set of plans.  changes include removal of light fixtures and revised energy calculations.  changes noted delta 2.  this is plan check only.  (((PC for T24 only for change of use TI from retail to restuarant. Installing new lights and kitchen equipment. Total area of 1058 sqft. Building # 17016-10000-17897.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39365	16041-10000-44240	3715 W SAN MARINO ST 1-19	90019	4	132B189  1117	5092022033	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.05453	-118.31375	Fire alarm installation to a commercial site. (6)FA panels, (160) FA devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39366	15041-20000-43308	3794 S WELLAND AVE	90008	10	117B189   733	5034005010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	PIN	34.01731944	-118.32579567	PV1, roof top solar installation:(4) SW-250P(4) Enphaase M215-60-2LLstandard plan is used	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39367	13041-20000-19903	4959 W SANTA MONICA BLVD	90029	13	144B197   728	5540009008	[Q]C2-2D	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.09098	-118.29784	Change to lighting and receptacles for an existing restaurant.  Load is less than 400 amps.  Occupancy load is less than 99, NOT A PLACE OF ASSEMBLY per applicant.  Plan Check Only for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39368	19041-10000-32026	110 E 9TH ST 5TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Energy plan check for a partial office T.I located on the 5th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 18,931-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39369	13041-20001-35552	8900 N DE SOTO AVE BLDG 101	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM			PC Approved	02/28/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	(((2/28/2014- CHANGES MADE TO APPROVED SET OF PLANS. REVISED TYPO ON THE SINGLE LINE DIAGRAM. THIS IS A PLAN CHECK ONLY APPLICATION)))FOR BLDG 101 ONLY,pc for power and energy. new equipment >600A. transformer and minor distribution. pc for new lighitng. 3034 sq ft seperate from power plan check. inpector to field verify new lighting loads. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39370	11041-10000-17303	15601 W NORDHOFF ST	91343	7	198B141   686	2656028019	[T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills			1172.01	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.23573	-118.47216	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39371	09041-10003-23895	2716 E MEDFORD ST	90033	14	133-5A229  15	5202023012	MR1-1	East Los Angeles	Northeast Los Angeles		YES	2031.00	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.06195	-118.19348	Install 'WattStopper' LS-102 Daylighting Controller for the warehouse section of the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39372	11041-10002-20652	1025 E ELKGROVE AVE BLDG 40	90291	11	111B145   625	4243003039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			12/17/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Expired	02/23/2017 12:00:00 AM	ADDRESS	34.00092	-118.45924	LINCOLN PLAZA APARTMENT BUILDING PROJECT  Changes made to previosly approved set.  addition of a 100 amps panel and 3 3.84 kva.    m.z  12-17-14.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39373	18041-20000-21196	11925 W STAGG ST	91605	6	189B165   836	2310019020	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.2122	-118.39309	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM RATED AT 10KVA - SYSTEM CONSIST OF 1 CENTRAL INVERTER WITH 33 MODULES WITH P400 OPTIMINERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39374	14041-20000-16560	18001 N TERRAFINA ST	91344	12	219B125    99	2601073024	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.29431	-118.5264	pv1install roof mounted pv system sized 7.2kw interconnected with msp. (1) power-one transformerless inverter pvi-6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39375	13041-10000-33169	7001 W HOLLYWOOD BLVD	90028	13	147B181   114	5548003001	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.1017	-118.34196	Plan check for power and energy.{{{ Description from building prmit: TENANT IMPROVEMENT OF (E) RETAIL SPACE: (N) STOREFRONT, EXTERIOR CANOPY, PARTITIONS, CEILING SYSTEMS AND MILLWORK.  INCLUDES INTERIOR WALK-IN COOLER AND REFRIGERATION UNITS.  SEE SHELL PERMITS # B12LA13799 & B13LA11074 FOR REFERENCE.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39376	16041-20000-12924	16650 W BLACKHAWK ST	91344	12	204B137   233	2684004017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.25822	-118.49539	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (21) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39377	19041-10000-36290	12229 W SANTA MONICA BLVD	90025	11	126B145   765	4263027017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.03995	-118.46537	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39378	13041-20000-26498	9210 N SAN FERNANDO ROAD	91352	6	198B169   119	2538002046	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			Verifications in Progress	11/22/2013 12:00:00 AM	ADDRESS	34.23693	-118.39033	PC FOR T24 ENERGY ONLY. SCOPE OF WORK IS TO REPLACE BALLAST AND LAMPS. NO CIRCUIT REWIRE AND NO NEW LOADS. TOTAL AREA FOR ENERGY CALC 167,723 SQ FT. NO EMERGENCY CIRCUITS UNDER SCOPE OF WORK. ALL EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39379	14041-10000-27371	147 W 109TH ST	90061	8	088-5A203  72	6074010023	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	33.93749	-118.27555	Solar PV roofmounted residential standard plan. # of inverters: 1. System Size: 6kW. # of modules: 28.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39380	14041-10000-31930	1550 N EL CENTRO AVE	90028	13	148-5A189 308	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.09961	-118.32359	Plan check for power only. Temporary power for construction, 1000A 480Y/277V temporary power service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39381	17041-10000-41994	8420 N BALBOA BLVD #112	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	PC for power and energy for first restuarant tenant. Installing new panel, new lights, receptacles and equipment. Total area is 1338sqft. B# 17016-10000-34410.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39382	12041-20000-22598	3575 N CAHUENGA BLVD W	90068	4	159B177   196	2425008023	C2-1VL, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	PIN	34.13362778	-118.35843173	T.I. change OF USE FROM OFFICE TO YOGA STUDIO.  Plan check for energy with emergency lighting. B Occupancy. load is less than 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39383	17041-10000-43433	3212 W LACLEDE AVE	90039	13	153B209   712	5436011004	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	02/10/2018 12:00:00 AM	ADDRESS	34.11436	-118.25178	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.8KWdc / 7.6KWac.(26)MODULES-HANWHA Q CELL Q.PEAK-G4(26)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE7600H-US RGM	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39384	10041-10000-18428	515 S FIGUEROA ST # 1550	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	REMODEL OFFICE AREASPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39385	16041-10000-30150	605 S VERMONT AVE	90005	10	135B197  1038	5502025900	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			Corrections Issued	01/19/2017 12:00:00 AM	ADDRESS	34.06335	-118.29185	Full PC for a new construction for a 7-story mixed use building 2-story museum with 5-story 103 units apartments above and 3 and half level basement parking garage. The main service is rated at 4000 A bus 120/208V 3phase, 4 wire. Total sqft 17252	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39386	17041-10003-08297	9171 N GAZETTE AVE	91311	12	198B109   142	2748036024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Issued	07/28/2017 12:00:00 AM	ADDRESS	34.23761	-118.58729	PC FRO CHANGES TO APPROVED SET OF PLANS. PROVIDED COMBINER BOXES AND UPDATED STRING CIRCUITRY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39387	16041-10000-31493	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Expired	10/18/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR AN EXISTING FIRE ALARM SYSTEM FOR AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING 18 FA PANELS FOR FLOORS 1ST, 2ND, 4TH, 7TH, 10TH, 13TH, 16TH, 19TH, 22ND, 25TH, 28TH, 31ST, 34TH 37TH, 40TH, AND 43RD FLOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39388	18041-20001-00928	10028 W MCBROOM ST	91040	7	207B181    66	2543010039	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.26358	-118.34876	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.45 kWac and consists of (1) inverter and (42) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39389	17041-10000-23222	10250 W SANTA MONICA BLVD # 9190	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	First tenant-Smitten Ice Cream- . Full plan chk	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39390	17041-10000-12036	812 S ROBERTSON BLVD	90035	5	135B169   206	4333015006	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.06244	-118.38338	TI TO JEWERLY STORE. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39391	17041-10000-27724	8119 N GEYSER AVE	91335	12	189B121    68	2103002030	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	08/26/2017 12:00:00 AM	ADDRESS	34.21805	-118.54281	PC for new rooftop solar for 18.98KW system with 55 AC modules and 1 combiner panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39392	14041-20000-32790	7416 N WISCASSET DR	91307	12	186B085   155	2017036014	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	PIN	34.20683421	-118.65930893	PV1INSTALL GROUND MOUNTED PV SYSTEM SIZED 15.2KW INTERCONNECTED WITH MSP.(60) Q-CELL Q-PRO G3 255 MODULES(2) SOLECTRIA PVI-7600TL TRANSFORMERLESS INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39393	12041-10000-09624	1840 S CENTURY PARK EAST Main Lobby	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Approved	04/27/2012 12:00:00 AM	ADDRESS	34.06188	-118.41473	Plan check T24 Energy/Emergency lighting for main lobby area remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39394	13041-10000-30049	5260 N BELLINGHAM AVE	91607	2	171B165   327	2347020015	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			10/28/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.1663	-118.39912	FA FOR (E) 4 STORY CONDO BUILDING. R-2 FULLY SPRINKLERED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39395	13041-20002-35614	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.98179	-118.40283	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE NEW ELEVATOR, CONDENSING UNIT, AND CHANGES TO T24. PC FOR DELTA 50 AND 51 REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39396	17041-10001-40926	10617 N TAMARACK AVE	91331	7	207B157   817	2620007015	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.26283	-118.42327	Changes to an approved set of plans, Scope of work includes the relocation of the Inverter, Main Panel, and AC disconnect under delta 1.PC FOR 5KW ROOFTOP PV. INSTALLING 24 MODULES WITH OPTEMIZERS AND ONE CENTRAL INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39397	14041-10000-34306	7324 N BELLAIRE AVE	91605	2	186B161   526	2324002029	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.20456	-118.40929	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 4724 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39398	19041-10000-01873	14718 W ARMINTA ST	91402	6	189B149   513	2210021023	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.21338	-118.45369	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39399	13041-20000-23474	12689 N GLENOAKS BLVD	91342	7	219B153    17	2508027013	QC4-1, QP-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.29988	-118.44185	RENOVATION OF SUPER MARKET. NEW WIRING AND NEW LIGHTING. MORE THEN 400A OF LOAD. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39400	14041-20001-24378	22620 W MIRANDA ST	91367	3	174B097   295	2040007011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.17455	-118.61981	Expedited plan check per applicant request.  PV1.  Install 9.72 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39401	15041-10000-12261	200 WORLD WAY SPACE 239	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	TI FOR TITLE 24, RETAIL SPACE TO REMAIN. PC FOR ENERGY ONLY. TOTAL SQ. FT. 1084.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39402	16041-20000-06243	865 S FIGUEROA ST FLOOR 29	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT  29TH FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39403	13041-10001-33013	13930 N BREGER AVE	91342	7	228B157    24	2582011019	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.32591	-118.43034	Expedited RSES plan check per applicant request.[[][][]]PV1, Install 10 kw DC roof-mounted solar array for a 2 story house, interconnect with the main service panel.(2)Transformered inverter(s): Fronius IG Plus A 7.5. (40) modules: Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39404	13041-10000-34760	1188 S SAN PEDRO ST SUITE N	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	PIN	34.03375994	-118.25280059	Remove HID light fixtures and replace with new fluorescent fixtures in existing retail space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39405	15041-10000-05295	800 WORLD WAY RMS 8232 &-8333	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	33.94305	-118.39757	installing UPS, PANELBOARDS in existing small rooms-Rooms 8232 and 8333-TERMINAL 8PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39406	12041-10000-11806	10125 N LASAINE AVE	91325	12	204B129   328	2734029016	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	08/01/2012 12:00:00 AM	ADDRESS	34.25481	-118.51251	Plan check 9.36KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39407	18041-10000-32521	1020 W ANAHEIM ST	90744	15	030B201   229	7416012039	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	09/24/2019 12:00:00 AM		Issued	09/24/2019 12:00:00 AM	ADDRESS	33.77911	-118.27495	Full plan check for a haz' location (gas station) with a new 600-Amp service. Scope covers all new rewiring with new lighting and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39408	16041-10000-08819	11916 W WILSHIRE BLVD	90025	11	129B145  1019	4263005029	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.04614	-118.46465	T-24, PC FOR ENERGY ONLY. TI FOR  A RESTURANT,  G-2 OCCUPANCY. SCOPE INCLUDES NEW LIGHTING, NEW RECEPTACLES,  AND 1 NEW 200A PANEL. TOTALAFFECTED  AREA 1245 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39409	10041-20000-00603	5901 W OLYMPIC BLVD	90036	4	132B177   666	5086024025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/13/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	07/14/2010 12:00:00 AM	ADDRESS	34.05771	-118.35996	NEW SOLAR SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39410	10041-10000-18845	1217 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/27/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.05169	-118.22662	Solar voltaic system installed on the roof of the building.  Consists of 5 modules, 5 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39411	12041-10000-17917	6556 N SAUSALITO AVE	91307	3	180B101   443	2038034029	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.18977	-118.61556	Plan check for PV System. Roof mounted. 7.848kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39412	14041-10000-10679	1048 S LA BREA AVE	90019	10	132B181   763	5084013019	C2-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.05644	-118.34498	TI FOR EXISTING TACO BELL RESTAURANT. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39413	15041-10002-02311	9030 S LOYOLA BLVD	90045	11	096B161   822	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	33.95663	-118.41787	((8/12/2015- CHANGES MADE TO APPROVED SET. REVISED PANEL SCHEDULES AND CHANGED LIGHTING. T24 TO BE VERIFIED)))PC FOR POWER AND ENERGY. DORMATORY AND ACADEMIC CLASSROOM BUILDING FOR OTIS COLLEGE OF ART AND DESIGN. TOTAL AREA  82,013SF. Fire alarm variance filed on 4/2/2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39414	19041-10000-50831	3617 S AVALON BLVD SUITE 100	90011	9	117A207-387	5121008039	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	04/21/2021 12:00:00 AM	ADDRESS	34.01296	-118.26553	FULL PLAN CHECK FOR POWER AND ENERGY. NEW 1600A SERVICE, 208/120V, 3 PHASE. SCOPE OF WORK INCLUDES CHANGE OF USE OF A WAREHOUSE TO A MEDICAL SERVICE FACILITY.  TOTAL AFFECTED AREA IS 10527 SQAURE FEET. *************************************A 7,642 SF AMBULATORY SURGERY CENTER TENANT IMPROVMENT SUITE IN AN (E) 20,000 SF BUILDING NO NEW SQUARE FOOTAGE ADDED TO EXISTING BUILDING CHANGE OF USE FROM WAREHOUSE TO MEDICAL OFFICE BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39415	15041-10000-30338	9619 W MONTE MAR DR	90035	5	129B165   565	4306012011	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.04944	-118.39765	PV1. Installation of a roof  mounted solar system interconnected with the main panel for a single family home. Scope of work: (1) inverter : 7.6 kw , (1) 125 Load center , (32) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39416	19041-10000-22611	6100 N WOODLEY AVE	91436	6	177B141     3	2251002906	OS-1XL-RIO, [Q]PF-1XL-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	06/30/2022 12:00:00 AM		Issued	06/30/2022 12:00:00 AM	ADDRESS	34.18088	-118.48309	PC for T24 only, scope of work is providing lighting and power loads for new restroom stalls, total affected area is 112 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39417	15041-20000-37176	1680 N VINE ST #1112	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for Title 24 only for existing space in high-rise Taft Building. Total area: 4,460 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39418	18041-20000-09807	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to create a new corridor on the 1st floor. Total lighting area = 2,076 sq. ft.Note: Building application has been generated under 18016-20000-08107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39419	14041-20000-10953	4939 N LOUISE AVE	91316	5	168B133   106	2290001012	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.15959	-118.51001	Roof mounted PV system with transformerless inverter.  PV system size 15KW. Note: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39420	15041-20002-31621	846 N SIERRA BONITA AVE	90046	5	141B177    39	5526003016	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM			PC Approved	07/30/2018 12:00:00 AM	ADDRESS	34.08667	-118.35415	7/30/2018 Changes to approved set.  Changes noted delta 5 only.  Clouded revisions hand-written in - approval is for clouds signed by plan checker only.  Revisions to EM egress lighting supply circuiting, other minor revisions.  (((7/16/2018changes to an approved set of plans.  changes noted delta 1 only.  changes to reflect field conditions and revisions to energy calculations and lighting fixtures.))) (((Plan check for power and Title-24 (energy).  Total area = 5,250 sq. ft. (conditioned) + 3,470 sq. ft. (unconditioned) + 1,860 sq. ft. (hardscape).New electrical distribution system for new elderly care facility with 8 guest rooms (10 beds) and underground parking area.  Low-rise building with 600 A service and backup generator.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39421	12041-20000-20838	3648 S KALSMAN DR	90016	10	117B173    60	4204020***	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Apartment			09/04/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.02009	-118.37467	Photovoltaic system on roof of apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39422	19041-20001-46683	2229 N STRADELLA ROAD	90077	5	153B145   169	4377011001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.11352	-118.46263	Expedite per applicant request. Plan check for PV roof mounted system, PV system size: 16.28KW DC, 15.03KW AC CEC with 44 AC Modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39423	13041-20000-26185	13633 W MORRISON ST	91423	4	168B157    59	2359017002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.16048	-118.4303	pv1 single family dwelling. total system size 3.8 kw AC using 17 modules. using transformerless inverter nonstandard plan. 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39424	14041-10000-22498	11676 W GATEWAY BLVD	90064	11	120B153    80	4258001049	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Issued	08/20/2014 12:00:00 AM	ADDRESS	34.0288	-118.44292	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 1815 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39425	16041-20000-02257	7926 N CHASTAIN AVE	91335	12	189B129   682	2101029005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.21437	-118.52351	PV1. Plan check for the addition of a 3 kW AC PV system onto an existing 6.9 kW PV system. For a total system size of 9.9 kW. New PV system consists of(10) Kyocera KU265 Modules(1) ABB PVI 3.0 Inverter(1) Bryant 125A Load Center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39426	15041-20000-11076	536 N WESTMORELAND AVE 1-8	90004	13	141B197   851	5539030019	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Apartment			04/14/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.08098	-118.28787	Installation of new central fire alarm system in new apartment building.  1 FACP + 14 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39427	16041-30000-12678	3615 S CARDIFF AVE 1-10	90034	5	120B165   128	4313017020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			04/12/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.02828	-118.39855	Plan check for new 10 units appartment  multi-restdentail building. Service size: 800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39428	15041-20000-10139	6224 N LONGRIDGE AVE	91401	2	177B157   329	2331003006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.18379	-118.42129	Plan check for a PV1 roof-mounted PV system. System size is 4.6 kWac and consists of (18) micro-inverters, (18) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39429	10041-20000-04351	1071 S GLENDON AVE	90024	5	132B153   117	4363020002	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	04/21/2010 12:00:00 AM	ADDRESS	34.0612	-118.4445	"TENANT IMPROVEMENT OF EXISTING RESTAURANT/BAR. REMOVE EXISTING BAR AND INSTALL NEW 8'-6""X25' BAR.  NO CHANGE TO EXISTING BASEMENT AND MEZZANINE LEVEL. NO CHANGE TO EXSITING KITCHEN LAYOUT, BATHROOM ON GROUND LEVEL."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39430	16041-20001-15087	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM			PC Approved	07/27/2017 12:00:00 AM	ADDRESS	33.79072	-118.29449	Revisions to approved set of plans.  Equipment yard layout changes and addition of seal-offs to conduit emerging from underground routing (methane zone).  Clouded revisions delta-6 and 7.  Design changes apply to both carport and ground mount systems permitted separately under 16041-20000-15087 and 16041-20000-15082.(((PV2. GROUNDMOUNTED SYSTEM. SYSTEM SIZE: 130 KW--------------------------------------------------------------------------------------------------------------------------------------ON SAME PLANS:PV2. ROOFMOUNTED SOLAR SYSTEM ON A CARPORT.  SYSTEM SIZE: 332 KW . LINE SIDE TAP.1024  MODULES BUILDING PERMIT # 16014-20000-01950 , 16010-20000-01727, 16010-20000-01728PLANS HAVE GROUNDMOUNTED SYSTEM AND CARPORT SOLAR ROOFMOUNTED SYSTEM ON SAME PLANS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39431	11041-10000-07647	6355 N DE SOTO AVE Bldg 2	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.18639	-118.58869	New 4 story 116 unit apartment building.  This application was generated to create a separate plan check and permit application for building 2.  The plan check submittal fee was adjusted to a lower value to account for building 2 plan check fees paid on  application 10041-10000-24305.The fee for permit is indicated under the inspection fee period for this application.The fire alarm plan and permit for building 2 was issued on application # 11041-10000-04061.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39432	15041-20001-21567	3340 W COUNTRY CLUB DR	90019	10	129B189   626	5081023036	RE9-1-O-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04982	-118.31564	"""EXPEDITED PER APPLICANTS REQUEST""PV1. GARGAGE ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19 KW DC."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39433	18041-20000-38674	9401 N CORBIN AVE Ste 100	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	34.24143	-118.56249	Plan check for Title 24 only in existing building, T.I. Office space in 1st Floor Suite 100. Total area: 3346 sq ft. B#18016-200000-15638	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39434	16041-20001-24902	8852 N AMESTOY AVE	91325	12	195B133   223	2690012001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.23187	-118.50682	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.160 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39435	14041-10000-10040	2450 W RIVERSIDE DR	90039	13	150A209   179	5438005017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.10517	-118.25568	ROOF-MOUNTED 1.5KW PV SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39436	11041-10000-20317	1910 W COLORADO BLVD	90041	14	162A223   105	5686007005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.13906	-118.20899	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39437	12041-20001-30853	232 E 2ND ST	90012	14	129A213   468	5161024011	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM			PC Approved	12/12/2014 12:00:00 AM	ADDRESS	34.0495	-118.24258	Revisions to approved set. THERE IS A CHANGE OF ENGINEER ON RECORD. THIS PLAN CHECK TO TO SUPERCEED THE PREVIOUS APPROVED SET OF PLANS.  (((Construct 5-story,  240-unit apartment with retail over garage, no disabled access.  Located in methane buffer zone. title 24 included, emergency lighting.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39438	18041-20000-43392	10855 W PORTOFINO PL	90077	5	147B149   524	4369039024	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.09666	-118.45812	permit fee $0.00 by state senate bill no. 1222PV1.  Install 19.5 kW roof mounted grid tied PV system.  (60) modules with (2) 10 kW rated string inverters.  40.5 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39439	10041-10000-18951	6060 W OLYMPIC BLVD	90019	10	132B177   670	5086001066	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	PIN	34.05782845	-118.36339619	New yogurt shop. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39440	16041-20000-04601	6767 W FOREST LAWN DR 303	90068	4	162B181   617	5581028005	C1-1D-RIO	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.14432	-118.33993	Plan check for energy only. TI to existing office on third floor (unit 303). New lighting (incl. emergency) and receptacles. 2,324sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39441	16041-10000-22125	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	NEW FIRE ALARM SYSTEM FOR AN EXISTING BLOOMINGDALE STORE IN CENTURYCITY MALL. 400NEW DEVICES, 2 COMMUNICATION PANEL, 14 CONTROL PANELS, AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39442	11041-10000-04478	501 W IMPERIAL HWY	90044	8	087A201   272	6075026026	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Approved	03/30/2011 12:00:00 AM	ADDRESS	33.93115	-118.2831	T.I. TO AN EXISTING MCDONALDS RESTAURANT.  SINGLE STORY, T-24 ONLY, OVER THE COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39443	18041-20001-32159	5147 S WEST BLVD	90043	8	108B185    96	5013003007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2018 12:00:00 AM			PC Approved	08/25/2018 12:00:00 AM	ADDRESS	33.99531	-118.33568	Expediate per applicant requestPlan check for PV roof mounted with battery back up sysgtem, system size: 7.6kW with 11 modules, 1 inverter(7.6kW) and 1 LG Chem RESU 9.8kWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39444	13041-10000-26122	380 WORLD WAY #T54-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of led sel-illuminated signs on the external walls of a the tenant space BVLGARI on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39445	13041-20000-02800	11132 W VENTURA BLVD	91604	2	162B173   371	2378009007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	ADDRESS	34.1414	-118.37315	Change to lighting, receptacles, loads, new panels on the 4th floor of an existing low-rise office space.  Load is 395.6 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39446	15041-10000-35185	1157 N FISKE ST	90272	11	129B129   288	4423003023	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.05059	-118.523	PV1 INSTALL 4.1 KW DC ROOF-MOUNTED SOLAR ARAY ON A SINGLE FAMILY HOUSE.(13) MODULES: LG315N1C-G4(1) INVERTER: SOLAREDGE 6000A-US 240	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39447	15041-20000-29987	9697 W WENDOVER DR	90210	5	156B157   248	4385022006	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.12419	-118.42935	Plan check for a PV1 roof-mounted PV system. System size is (12) kWac and consists of (2) inverters, (1) load center, and (47) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39448	17041-20002-42262	8755 W YATES ST	91040	7	204B189   414	2546002019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	ADDRESS	34.25675	-118.32433	Revision to approved set of plans.  Reduction of system scope - ESS component of project scope removed.  $0 plan check fee due to State Senate Bill SB 1222. (((pv1install roof mounted pv system sized 5kw interconnected with msp, with battery back up.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39449	16041-20000-13906	3844 W 27TH ST	90018	10	123B185   933	5051015002	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Apartment			04/21/2016 12:00:00 AM			PC Info Complete	03/22/2017 12:00:00 AM	ADDRESS	34.03108	-118.32685	Plan check for power and energy. New 3-story, type VA, 16-unit apartment building with one level basement parking garage. 1200A overhead service. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39450	11041-10000-24575	1050 S FREDERICK ST BLDG #60	90291		111B145   881	4243003032	[Q]RD1.5-1XL		Venice	Venice			Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM			Ready to Issue	08/14/2012 12:00:00 AM	ADDRESS	33.99927	-118.46029	Lincoln Place Apartment Building Project.  New Leasing Office, Bldg #60	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39451	19041-10000-35439	2316 E IMPERIAL HWY	90059	15	084B217    22	6067014901		South Los Angeles				2431.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	33.92887	-118.23076	Plan check for a fire alarm system located in a single story commercial building. Scope includes (1) FACP (1) communication panel, and (57) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39452	16041-20000-33771	10000 N CANOGA AVE #4	91311	12	204B105   792	2747008040	CM-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.25175	-118.59713	Remove existing hid light fixtures and replace with new led light fixtures indoor.  plan check for energy only.  total square footage 1736.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39453	11041-20000-17190	15233 W VENTURA BLVD 8,9 fl.	91403	5	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.1538	-118.46502	Fire Alarm t.i. for 8th & 9th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39454	10041-10000-25682	11333 N SEPULVEDA BLVD	91345	7	213B145   166	2664001801	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1092.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.27646	-118.46863	TI for a medical building. Core & Shell were submitted under separate application 10041-10000-25688. EPC is for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39455	19041-20000-36657	6241 N GLADE AVE	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	06/02/2021 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.184	-118.60789	PV2. Plan check for Pv roof mounted system, PV system size: 23.49KW DC, 20.9KW AC CEC with 54 PV Modules and 2 inverters(9.0KW)Note: This is 12 Buildings on 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39456	15041-10000-00470	2049 S CENTURY PARK EAST suite 2660	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project is an existing suite in an existing high-rise building. Total lighting area = 2,092 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39457	11041-10000-20319	6625 N LANKERSHIM BLVD	91606	2	180B169   478	2322018026	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.03	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.19118	-118.38798	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39458	19041-10000-50136	20934 W VICTORY BLVD	91367	3	180B109   589	2149003037	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	11/10/2020 12:00:00 AM		Permit Finaled	09/01/2021 12:00:00 AM	ADDRESS	34.18815	-118.58989	REPLACING FIRE DAMAGED EQUIPMENT LIKE TO LIKE. SCOPE OF WORK INCLUDES 3 NEW PANELS, CIRCUITS & LIGHTS.  TOTAL AFFECTED AREA 7,750SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39459	17041-20000-02787	9116 W ST IVES DR	90069	4	144B169   247	5560031002	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.09326	-118.39052	pv1install roof mounted pv system sized 7.7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39460	16041-10000-45677	1028 W D ST BLDG 1	90744	15	027B201   420	7417010946	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM				PC for new fire alarm system with 42 devices and 2 panels for apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39461	11041-10000-00192	3636 W BEVERLY BLVD	90004	13	138B197   449	5501009024	M1-1	Central	Wilshire	Rampart Village	YES	2111.10	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	07/29/2011 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	ADDRESS	34.07557	-118.28737	"INSTALL A NEW FIRE ALARM SYSYETM IN A ""PUBLIC STORAGE BUILDING""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39462	16041-20003-41832	644 N HOBART BLVD #1-12	90004	13	141B193   672	5521005005	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.083	-118.30564	"03-07-2019 Changes to an approved set of plans, Changes include service down size to 600A Service, update fault current and addtion of meter section for Car Charger. All Changes has been clouded as delta ""B"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39463	17041-30000-19015	801 S FIGUEROA ST 10 Floor-Corridor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only in existing space 10th floor corridor. Total area: 1650 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39464	14041-10000-11584	8 S CHESTER PL Bldg 8 1/2	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Closed	10/17/2017 12:00:00 AM	ADDRESS	34.03102	-118.27718	plan check for power only. SERVICE UPGRADE FOR (E) SFD BLDG 8 1/2 at Mount St. Mary's College.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39465	16041-10004-29628	10319 N NORRIS AVE	91331	7	204B165   115	2537004029	[Q]M1-1-CUGU, [Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.25712	-118.40313	CHANGE TO APPROVED SET. CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO WARNING LABELS AND SERVICE ENTRANCE CONDUCTOR SIZE. PC ONLY. PERMIT ALREADY ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39466	10041-10000-16575	1212 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.05014	-118.22697	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39467	19041-10000-06211	9300 S SAN PEDRO ST	90003	9	094-5A205 375	6052022016	RD2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Issued	02/21/2019 12:00:00 AM	ADDRESS	33.95183	-118.26936	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39468	14041-20000-13616	9103 W CATTARAUGUS AVE	90034	5	123B169   348	4301003039	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.03541	-118.391	Roof mounted PV system with transformerless inverter.  PV system size 5.9KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39469	11041-20000-20232	3100 W BEVERLY BLVD	90057	13	138A201   278	5155002026	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.07177	-118.28246	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39470	10041-10000-19308	676 S CENTRAL AVE	90021	14	124-5A215  15	5147035001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.03703	-118.2407	TI IN AN EXISTING OFFICE. PLAN CHECK FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39471	15041-10000-09818	600 WORLD WAY TM 6, #650	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR POWER AND ENERGY. TERMINAL 6 OF LAX. FIRST TIME TENANT. TOTAL AREA 546 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39472	19041-20000-30117	10858 N VENA AVE	91345	7	207B149    51	2615027007	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM			PC Approved	08/02/2019 12:00:00 AM	ADDRESS	34.26766	-118.44797	PV1.  Install 3.57 kW roof mounted grid tied PV system.  (14) module with 4.2 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39473	10041-20000-05849	11142 W FLEETWOOD ST	91352	6	195B173   348	2408026033	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.22988	-118.37387	Repair & replace fire damageEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39474	18041-10000-06636	947 S TIVERTON AVE 1-494	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			06/28/2018 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	09/23/2021 12:00:00 AM	ADDRESS	34.06246	-118.44303	Full plan check for renovation of an existing 14 story building and underground parking. New service rated at 3000A 277/480V 3ph 4W. There is emergency generator for Emergency load and Standby load as well as Fire Pump. Additional plan check also done under supplemental: 18041-10001-06636Bulding Permit: 17016-10000-27541	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39475	17041-20000-25114	9841 N AIRPORT BLVD 5th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only. this is plan check onlyinspection fees paid under applicfation 17041-70000-21514	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39476	19041-10000-51229	6451 N VALLEY CIRCLE TER	91307	12	180B089   834	2032025014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.18715	-118.65604	(E-PLAN)NEW INSTALLATION OF 1 ENERGY STORAGE SYSTEM AND 1 PANEL OF 125 AMPS FOR AN EXISTING SOLAR SYSTEM WITH A SERVICE OF 200 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39477	15041-20000-33690	9422 N RUFFNER AVE	91343	12	198B137   120	2687015020	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.24233	-118.497	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(28) TRINA SOLAR MODULES TSM-250(28) POWER OPTIMIZERS P300(1) SOLAREDGE SE7600 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39478	18041-20000-18526	14846 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.29457	-118.45462	PV1.  Install 3.78 kW roof mounted grid tied PV system.  (12) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39479	18041-10000-39136	10250 W SANTA MONICA BLVD #9255	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM			PC Info Complete	12/11/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR First time T.I. of kiosk space ""Amazon"" enclosed with ceiling for power and energy. scope includes new panel and lights.total affected area 300sq.ft B# 18016-10000-33107"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39480	18041-10000-21433	9640 N OWENSMOUTH AVE	91311	12	201B105   205	2746015006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM			PC Info Complete	06/27/2018 12:00:00 AM	ADDRESS	34.24548	-118.60221	PC FOR POWER FOR NEW SERVICE 3000A 277/480V 3PH.CONNECTED TO EXISITNG 2500A DISTRIBUITION (APPROVED UNDER SEPRATER PERMIT).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39481	18041-10002-07233	200 E BAUCHET ST	90012	14	133-5A215 236	5409015017	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	09/04/2020 12:00:00 AM		Permit Finaled	05/17/2021 12:00:00 AM	ADDRESS	34.05873	-118.23498	"DELTA ""20"" CHANGES TO APPROVED PLANS. INSTALLING 4 ADDITIONAL 300KVA PDU UNITS, NEW CIRCUITS AND 173,268 SQR FT OF ENEGRY PLUS OTHER VARIOUS CHANGES TO THE DESIGN. <<<FULL PLAN CHECK OF A NEW 4-STORY DATA CENTER BUILDING (LA3).  (4) New services at 600A 34.5 k; (4) 34.5kV/12.47kV xfrmr, (3) medium voltage dist. boards; (6) medium voltage unit substations; other equipment are 600V or less.   18010-10000-00872>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39482	19041-30000-11191	126 S KINGS ROAD	90048	5	138B173   714	5511016018	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	10/05/2020 12:00:00 AM	ADDRESS	34.07361	-118.37198	Plan check for a fire alarm system for a 4-story, 8-unit apartment building. Fire alarm consists of (1) FACP and (57) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39483	17041-20000-07345	232 E 2ND ST Suite #E	90012	14	129A213    28	5161024034		Central				2062.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Closed	04/18/2020 12:00:00 AM	ADDRESS	34.0495	-118.24258	Plan check for power and energy. First time tenant - Panini cafe (restaurant), Suite #E. T24 area: indoor - 3,492sqft; outdoor - 1,147sqft.Note: Building application has been submitted under 17016-10000-05930	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39484	15041-20000-12005	11103 N RENAISSANCE DR	91042	7	210B197   513	2552047007	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.27102	-118.29398	Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39485	16041-10000-36157	9603 N SUNLAND BLVD	91040	7	201B177   318	2542021028	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Issued	10/12/2016 12:00:00 AM	ADDRESS	34.24627	-118.36203	roof mounted solar - PV1 SFD TOTAL SYSTEM SIZE 11.48KWdc / 9.84KW AC USING MICROINVERTER SYSTEM ENPHASE M250. TOTAL OF 41 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39486	15041-10000-22314	649 W ADAMS BLVD	90007	1	123A203   204	5124026013	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Issued	07/14/2015 12:00:00 AM	ADDRESS	34.02895	-118.27743	New fire alarm system for a 2-story commercial building ; Scope includes (1) fire alarm panel and (24) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39487	18041-20000-32291	17818 W SIMONDS ST	91344	12	210B129    28	2711017013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.27623	-118.52238	Plan check for a PV1 roof-mounted PV system. System size is 8.58 kWdc/7.88 kWac-CEC and consists of (26) micro-inverters, (26) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39488	17041-20002-37893	9537 N ENCINO AVE	91325	12	201B129   396	2755009047	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.24444	-118.5157	expeditepv1install roof mounted pv system sized 11.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39489	18041-10000-24597	3341 W 43RD PL	90008	10	114B185  1144	5024019906	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	07/11/2023 12:00:00 AM	ADDRESS	34.00441	-118.33097	REPLACING FIREALARM PANEL AND 44 NEW DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39490	13041-20001-21462	10140 N LEMONA AVE	91345	7	204B149   329	2647002029	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM			Reviewed by Supervisor	08/20/2013 12:00:00 AM	ADDRESS	34.25504	-118.45853	((EXPEDITE FEE))PV1 TRANSFORMERLESS SYSTEM. 5000 KW SYSTEM. 24 MODULES WITH POWER OPTIMIZERS AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39491	12041-20000-06563	8230 N FALLBROOK AVE	91304	3	192B097   470	2013003004	P-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.21872	-118.62324	New fire alarm system for day care center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39492	11041-20002-09507	20720 W MARILLA ST	91311	12	201B109   178	2748004046	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM			PC Approved	05/17/2012 12:00:00 AM	ADDRESS	34.24798	-118.58532	lighting changes to approved plan under 11041-20001-09507. Plan check for energy. Emergency lighting was approved on 11041-20001-09507. 18651 sqft. Film studio.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39493	10041-20000-24704	10826-10830 W KLING ST	91602	2	168B173   742	2421024019	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			12/10/2010 12:00:00 AM			PC Info Complete	07/26/2011 12:00:00 AM	ADDRESS	34.1555	-118.36671	Resubmit electrical plans for new 4-story 12 units apartment with subterranean garage.  New 800A service, switchboards, panels, equipment, branch circuits, and lightings.  Plan check for power and energy. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39494	10041-10000-12196	3335 S FIGUEROA ST 1ST FLOOR	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM	07/21/2010 12:00:00 AM		Permit Finaled	10/20/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	FIRST TIME TENANTS ON PORTION OF THE 1ST FLOOR IN USC (UNIVERSITY GATEWAY).  CORE & SHELL APPROVED UNDER A DIFFERENT PERMIT NUMBER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39495	11041-20000-19933	5410 N FENWOOD AVE	91367	3	171B093    36	2044002025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	34.16874	-118.63517	New installation of 9.67KW roof mounted photovoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39496	19041-20000-07884	6561 N BONNER AVE	91606	2	180B173   529	2336004010	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.1901	-118.37384	PLAN CHECK FOR NEW 11.02KW DC/10KW AC ROOF MOUNTED PV SYSTEM FOR EXISTING SFD, SCOPE OF WORK INCLUDES (38) REC SOLAR REC290TP2 PV MODULES, (38) SOLAR EDGE P320 OPTIMIZERS, AND (1) SE10000H INVERTER. MAIN BREAKER IS BEING DERATED FROM 200A TO 175A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39497	15041-20000-40166	5404 S JANDY PL	90066	11	105B161   885	4211006004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	ADDRESS	33.98159	-118.41622	Fire alarm plan check only. Install new notification devices on existing FACP. Install two new power supplies for 90 new notification devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39498	14041-10000-17443	4700 W WILSHIRE BLVD	90010	4	132B185    28	5090008031	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.06183	-118.3324	PC FOR POWER AND ENERGY. TI OFFICE. TOTAL AREA 61500 SQ FT. BUILDING APP# 14016-10000-12621.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39499	18041-10001-06926	330-332 N PATTON ST	90026	1	135A209    35	5160009004	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			08/15/2019 12:00:00 AM			PC Approved	12/02/2019 12:00:00 AM	ADDRESS	34.06594	-118.25864	REVISING DESIGN OF ELECTRICAL SYSTEM. APPLICANT REQUESTS ISAAC ALMARAZ FOR PC. PC ONLY. PERMIT TO BE PULLED UNDER MASTER APPLICATION 18041-10000-06926_____________________________________________________________PC FOR POWER AND ENERGY FOR A 6-STORY, 32 UNIT APPARTMENT BUILDING OVER 1 LEVEL SUBTERRANIEAN GARAGE. SCOPE INCLUDES ADDING A NEW 1600A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELBOARDS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 22891 SQ. FT. B#17010-10000-04956	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39500	16041-10000-01270	328 W 1ST ST	90731	15	018B201   661	7449023032	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.74343	-118.28412	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.6KW INTERCONNECTED WITH MSP.(19) KYOCERA 2656 MODULES(1) ABB 3.6KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39501	11041-20000-16973	800 W OLYMPIC BLVD	90015	9	127-5A207 340	5138027***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Expired	09/03/2013 12:00:00 AM	ADDRESS	34.04484	-118.26453	Ti in an existing offiice on the 4th floor. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39502	18041-20000-14002	9400 N MASON AVE	91311	12	198B109    68	2748022048	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.2413	-118.57962	Plan check for Title 24 only. Electrical work for (E) 3600 sq ft storage building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39503	19041-20000-18564	6538 N DEBS AVE	91307	12	180B089   524	2034021027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.18934	-118.65006	pv1install roof mounted pv system sized 8.4KW AC interconnected with msp.this is plan check only.  permit fees paid under application number 19041-90000-04359	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39504	16041-10000-35047	3358 E OLYMPIC BLVD	90023	14	118-5A225 252	5190034023	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM			Reviewed by Supervisor	10/12/2016 12:00:00 AM	ADDRESS	34.01859	-118.20616	PC FOR POWER AND ENERGY. CONSOLIDATING TWO  TENANT SPACES  INTO ONE.  TNENANT IMPROVEMENT, SERVICE SIZE 600 A 120/240 V, 3W, 1 PHASE. ADDITION OF 4 NEW  200 A PANELS. TOTAL AREA 3041 SQ.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39505	12041-10000-23002	13833 W VENTURA BLVD	91423	5	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	ADDRESS	34.1487	-118.43426	(#103)  CHANGE OF USE FROM RETAIL/OFFICE TO MEDICAL OFFICE; EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39506	14041-20000-02562	3160 N COLDWATER CANYON AVE	91604	2	159B161   231	2384024011	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Issued	01/29/2014 12:00:00 AM	ADDRESS	34.13134	-118.40812	PC FOR 2008 NEC. BUILDING SUBMITTAL DONE IN 2012. BASED ON 2008, PC FOR NEW SERVICE ONLY. PER APPLICANT REQUEST, NO PLAN CHECK FOR BRANCHES AND PANELS, SERVICE ONLY. NEW 1200A 3PHASE SERVICE FOR SINGLE FAMILY. ALL FUTURE LOADS REQUIRE FULL PLAN REVIEW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39507	14041-20000-01957	6033 W CENTURY BLVD 10th floor	90045	11	090B169    17	4124030037	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	33.94572	-118.38954	Remodel existing commercial offices with lights and receptacles.  Load is less than 400 amps, Plan Check Only for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39508	14041-10000-07093	11365 W CHARNOCK ROAD	90066	11	117B157   762	4249029003	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.01431	-118.42394	PV1, INSTALL 8.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800-US-ZB-U(34)MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39509	13041-20001-24421	19332 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1, [Q]R3-1VL	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.23457	-118.55484	(((CHANGES MADE TO APPROVED SET OF PLANS. ADDED GARBAGE DISPOSAL AND REVERIFYING CIRCUITS)))1st time tenant, New restaurant.  Plan check for shell of building is currently in plan check.  FULL PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39510	19041-20001-19952	7665 N SALE AVE	91304	12	189B097  1169	2013018006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.21021	-118.61883	Expedite plan check fee.PV1.  Install 13.86 kW / 11.78 kW AC roof mounted grid tied PV system.  (42) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39511	12041-10000-05909	632-638 S LANDFAIR AVE 1-16	90024	5	135B149   344	4363006008	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.06666	-118.44875	New 16 Unit apartment complex with 1200A service and house panel.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39512	19041-10000-18033	3740 W DON FELIPE DR	90008	8	114B181   522	5026001001	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Issued	05/14/2019 12:00:00 AM	ADDRESS	34.00673	-118.3404	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39513	10041-20001-18245	8244 N VAN NUYS BLVD	91402	6	192B149   434	2212004001	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.22099	-118.44858	PLAN CHECK T24 ENERGY FOR GENERAL/EMERGENCY LIGHTING FOR TI OF RETAIL STORE. INSTALL. PERMIT TO INSTALL NEW LIGHTING, EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39514	14041-10006-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/08/2018 12:00:00 AM			PC Approved	03/08/2018 12:00:00 AM	ADDRESS	33.95637	-118.3838	DELTA 10 & 11 CHANGES TO PERMITTED SET OF LANS.LIST OF CHANGES ARE ATTACHED TO THE REVISED PLANS((((((((New building construction.  61 unit 4 story apartment building with new 3kA electrical service.  63,272 sq. ft. of common area included on title 24 forms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39515	18041-10000-00292	615 S LA FAYETTE PARK PL	90057	10	135A201   216	5077006900	OS-1XL	Central	Wilshire	MacArthur Park, Rampart Village, Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	01/08/2021 12:00:00 AM	ADDRESS	34.06239	-118.28293	PC FOR POWER AND ENERGY FOR A NEW THREE STORIES PERFORMING ARTS CENTER. NEW BUILDING MADE FROM MODULAR STATE APPROVED SHIPPING CONTAINERS.  NEW SERVICE RATED 1600A 120/208 .SCOPE INCLUDES NEW PANELS,  EQUIPMENT AND CIRCUITS. TOTAL AFFECTED AREA 22239 SQ. FTB# 16010-10000-06088Foundation and Zoning Plan Check only by the City of LA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39516	19041-10000-18358	2115 S BURNSIDE AVE	90016	10	126B177  1449	5063019018	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.03805	-118.35859	PV1 roof mounted, system size is 5KWac. Scope of work includes 20 modules (HANWHA Q-Cell Q Plus 285 W) with optimzers (Solaredge P320) and a centreal inverter (SE5000H-US).  Leading to a new subpanel (125 A).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39517	13041-20000-34353	16007 W LASSEN ST	91343	12	201B141   157	2669024007	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM			Reviewed by Supervisor	12/19/2013 12:00:00 AM	ADDRESS	34.25026	-118.4808	PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING 3 STRINGS TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39518	13041-20000-01266	7948 W MCGROARTY ST	91040	2	204B193  1428	2559029028	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	03/05/2013 12:00:00 AM	ADDRESS	34.2521	-118.30645	PV-1. INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM. 7.8KW. Plan check due to 3 strings per inverter. Zoning clearance on 13041-20000-01232.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39519	15041-20000-25720	1115 N MAHAR AVE	90744	15	033B213   316	7425031013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Issued	08/10/2015 12:00:00 AM	ADDRESS	33.78582	-118.24657	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is site lighting. Total outdoor lighting area = 22,414 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39520	18041-10002-05548	420 S WESTLAKE AVE	90057	1	133-5A205 204	5154026016	R4-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	34.06005	-118.2727	"DELTA ""B""  & ""C"" CHANGES TO APPROVED PLANS FOR REDUCING THE NUMBER OF PV PANELS FROM 240 TO 191. THE SIZE OF THE PV SYSTEM IS 66.85KWdc / 63KWcec-ac.NOTE: Permit is paid under PCIS#18041-10000-05548"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39521	14041-20000-01261	150 E 46TH ST	90011	9	112-5A205 272	5109002034	R2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.00185	-118.27278	New rooftop mounted PV system for an existing single family dwelling.  System uses Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39522	18041-10000-04578	310 N FAIRFAX AVE	90036	5	138B177   379	5527037030	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			PC Info Complete	02/15/2018 12:00:00 AM	ADDRESS	34.07655	-118.36127	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR WORK ONLY. TOTAL AFFECTED AREA 17900 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39523	13041-10000-23798	6501 N FALLBROOK AVE	91307	12	180B097   471	2038040016	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.1881	-118.62368	New manual fire alarm system with central station monitoring in one-story restaurant building.  40 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39524	19041-10000-45569	384 WORLD WAY SPACE M34	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM			PC Info Complete	11/12/2019 12:00:00 AM	ADDRESS	33.94339	-118.40887	FULL PC FOR A TI (FIRST TIME TENNANT RETAIL SPACE), M34 - MIDFIELD MARKET - SCOPE OF WORK IS ADDING A NEW PANEL, CONNECTED TO AN EXISTING ELECTRICAL SYSTEM (TERMINAL IN LAX), TOTAL AFFECTED AREA IS 910 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39525	16041-20000-16021	23308 W BERDON ST	91367	3	174B093   448	2044001024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.17081	-118.63455	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(60) KYOCERA MODULES(2) ABB INVERTERSNote: $0.00 permit fee due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39526	14041-10000-28440	533 W 5TH ST LEVEL 54	90731	15	015B197   205	7451028039	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Expired	11/17/2022 12:00:00 AM	ADDRESS	33.73956	-118.28867	PLANCHECK FOR  ENERGY ONLY. TENANT IMPROVEMENT FOR US BANK BUILDING. PLANCHECK PER APPLICANTS REQUEST. LEVEL  54.(((notified by email. phone number may be wrong)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39527	19041-20000-07828	700 S FLOWER ST 4TH FLOOR-SUITE C	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only in existing space Tenant space. Total area: 4136 sq ft. B#18016-30000-35835	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39528	17041-10000-22667	515 S FLOWER ST STE 1700	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Issued	09/12/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC for power and energy for TI of entire floor in office building . PC for one new panel and 172 circuits. Building #17016-10000-17955. Total affected area is 20979 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39529	12041-10000-16257	8241 S DELGANY AVE	90293	11	096B153   671	4115004010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	33.95912	-118.4421	Plan check for new roof mount 5.89 Photovoltaic system for single family dwelling. (3 strings)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39530	19041-20000-20445	16958 W HALSTED ST	91343	12	201B133   613	2686023021	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.24414	-118.50208	Plan check for PV roof mounted system, system size: 12.06KW DC, 10.25KW AC with 36 PV Modules and 36 microinverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39531	16041-10000-42772	17320 W TRAMONTO DR 1-3-Bldg 9	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building  4 story 3 units (Type C) .  With 1 service 4,000A feeding all 9 buildings.Performance methond is being use for Title 24. Total area: 12,623 sq ft. Note: This is 9 buildings submit  in 1 plan. 9 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39532	17041-20002-10064	9171 N DE SOTO AVE BLDG A	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.23778	-118.5888	1/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes were made to the lighting and power floor plans. Scope also includes a new 200A panel. ************17041-20001-10064 previous changes07/25/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes were made to the lighting and power floor plans. The engineer of record has changed.*****Previous Work Description*****(N) 1 STORY RETAIL BLDG SHELL ONLY.  Plan check for power and energy.  Building A.  Building B permit is being submitted concurrently on same set of plans.  Building permit filed under 17010-20000-00221.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39533	19041-20000-20935	10550 N SEPULVEDA BLVD 101A,-101B	91345	7	207B145   469	2649011017	P-1VL, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.26235	-118.46697	TI to (E) ground floor commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39534	18041-10001-47963	712 S LINCOLN BLVD	90291	11	111B145   851	4243030004	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM			PC Approved	02/26/2019 12:00:00 AM	ADDRESS	33.99969	-118.46402	Supplement to an approved PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 1625 SQFT AREA.bld# 18016-10000-36794	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39535	13041-20001-22940	10070 W MCBROOM ST	91040	7	207B181   108	2543009024	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.26297	-118.35	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.5 KW USING 34 MODULES. USING ENPHASE MICROINVERTERS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39536	11041-10000-12421	1545 W WILSHIRE BLVD 2nd fl	90017	1	132A205   208	5142027025	CW	Central	Westlake			2091.02	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Issued	08/16/2011 12:00:00 AM	ADDRESS	34.05543	-118.26977	new panelboard and circuits in renovating offices on the2nd flplan check is for title24 and 1 ea emergency ckt ; permit fee is in Inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39537	14041-10001-04682	331 E 113TH ST	90061	8	087A205   186	6073026027	R2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/02/2014 12:00:00 AM	ADDRESS	33.93213	-118.26828	EXPEDITED RSES PLAN C HECK PER APPLICANT REQUEST.[{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES:  CNADIAN SOLAR CS6P-250PX}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39538	19041-20000-36925	11115 W VANOWEN ST	91605	2	183B173   186	2319005018	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.19409	-118.37253	Upgrades to commercial warehouse/office shell space for future TI.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39539	18041-10000-28250	2501 W 3RD ST	90057	13	135A203    83	5154015021	C2-1, R3-1	Central	Westlake	Westlake North	YES	2085.02	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.06513	-118.27659	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39540	13041-10000-33774	8700 W BEVERLY BLVD G157A	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.07666	-118.3805	PLAN CHECK FOR POWER AND ENERGY. Research lab imaging equipment replacement. ADDING A UPS , A LIFT AND A 225A PANEL.  AT CEDARS SIANAI MEDICAL CENTER. 470 SQFT. UNIT G157A - Ground floor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39541	14041-10000-07109	8960 N HERRICK AVE	91352	6	195B173   138	2408031901	M2-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.23145	-118.37348	change of engineer and contractor. change of inverter (SOLECTRIA PVI 60KW AND 95KW . MODULE remains the same. CARPORT (nonrooftop solar)old description 12041-10000-06285: Plan check ground mounted 158 KW photovoltaic system and T24 Energy outdoor lighting at LAUSD maintenance and office site. In Methane Buffer Zone. Includes additional permit for new branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39542	19041-20000-23599	902 N VIRGIL AVE	90029	13	144A201   322	5539007025	R3-1	Central	Hollywood	East Hollywood	Yes	1914.10	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.08791	-118.2867	T24 PLAN CHECK FOR TI TO EXISTING BAR. LIGHTS AND OUTLETS ONLY, TOTAL SQUARE FOOTAGE = 558 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39543	15041-10000-43654	2307-2309 S SPAULDING AVE	90016	10	123B173    34	5064028016	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.03724	-118.36782	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER. (12) MODULES AND (1) INVERTER 3.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39544	16041-10001-45788	802 S FRIES AVE	90744	15	024B205    34	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			PC Approved	06/01/2018 12:00:00 AM	ADDRESS	33.76172	-118.26356	EXPEDITED FEES:PV2 ROOF MOUNTED SOLAR SYSTEM IN A COMMERCIAL BUILDING IN THE PORT LA. TOTAL OF 2720 MODULES AND 10 INVERTER (83KW EACH ONE) SOLAR SYSTEM IS TYING INTO A 1200A 4160V SWITCHBOARD AND UTILITY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39545	19041-20000-40259	1223 S WELLESLEY AVE	90025	11	126B145   451	4267036009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Apartment			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	34.0421	-118.46871	Plan check for new fire alarm system for 4 story 10 units multi-family building. Total fire alarm devices: 85 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39546	11041-20000-22591	10148 N FERNGLEN AVE bldg . 2	91042	2	204A197   327	2558023022	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			10/21/2011 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Finaled	12/26/2012 12:00:00 AM	ADDRESS	34.25376	-118.29421	NEW 5 UNIT APT W/ATT GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39547	13041-10000-30245	5971 W VENICE BLVD	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.03865	-118.37272	New fire alarm for keiser West LA, 4 story, 762 devices, 10 remote power supply, one fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39548	16041-10000-20427	1230 W 39TH PL	90037	8	117B197  1038	5037005002	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Expired	07/16/2018 12:00:00 AM	ADDRESS	34.01401	-118.2983	PV1, rooftop solar installation on SFD, 3.8 kW AC system,   (20) CS6P-265     (1) Primo 3.8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39549	13041-20000-25178	15040 W BASSETT ST	91405	6	183B145   562	2220016016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.19608	-118.4612	PV1 SINGLE FAMILY DWELING. TOTAL SYSTEM SIZE 4.7 KW AC USING 22 MODULES. USING ENPHASE MICROINVERTER M215. NONSTANDARD PLAN. 2 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39550	16041-10000-04767	8372 W 3RD ST	90048	5	138B173   843	5511031022	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.0728	-118.37249	T-24, TI TO AN (E) RETAIL STORE, SCOPE OF WORK INLCUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. F.T 1225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39551	16041-20001-10159	3015 S WEST VIEW ST	90016	10	120B177   677	5049034015	R2-1, [Q]C1.5-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.02647	-118.35328	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, CHANGES MADE TO SINGLE LINE, CHANGING ALL SQUARE D EQUIPMENT TO SIEMENS MODEL. CLOUDED DELTA 4 CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39552	13041-10000-18877	9304 N HAYVENHURST AVE	91343	12	198B137   537	2676002012	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.23956	-118.49359	PV1 4.9kw 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [ 1INV: POWERONE PV-3.6-OUT-S-US-Z] [ 20MOD: TRINA TSM-245PC05.18}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39553	17041-20000-08276	7412 N BALBOA BLVD	91406	6	186B133   704	2226029004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM			Reviewed by Supervisor	03/31/2017 12:00:00 AM	ADDRESS	34.20514	-118.50093	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39554	10041-10000-05354	10984 W STRATHMORE DR	90024	5	135B149   422	4363008007	[Q]R4-1VL	West Los Angeles	Westwood			2653.05	Electrical	Electrical	Apartment			03/24/2010 12:00:00 AM	06/28/2010 12:00:00 AM		Permit Finaled	07/19/2011 12:00:00 AM	ADDRESS	34.06595	-118.45005	New 10 units apartment.  Plan check for energy and power.  Variance to separate the electrical and fire warning system plans was submitted on May 26, 2010.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39555	14041-20000-11719	17037 W ALBERS ST	91316	5	174B133   706	2258030003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.17044	-118.50466	pv1 single family dwelling. total system size 4.5kw ac using microinverter. using enphase m215. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39556	16041-10000-17639	1729 S LIVONIA AVE	90035	5	129B169  1013	4305023022	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.04811	-118.38692	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.84KWdc / 11.4KWac.(37)MODULES-SOLARWORLD SW320 XL MONO(37)OPTIMIZERS-SOLAREDGE P400 (1)INVERTER-SOLAREDGE SE11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39557	14041-20001-35036	11415 N RUGGIERO AVE	91342	7	213B173   387	2529020027	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.27724	-118.36694	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 15.8KW INTERCONNECTED WITH MSP LINE SIDE TAP.(65) LG280S1C-B3 MODULES(3) SOLAR EDGE INVERTERS(65) POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39558	17041-20000-41675	12117 W VALLEYHEART DR 1-23	91604	2	165B165  1117	2367014041	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Apartment			11/16/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.14595	-118.39679	INSTALLATION OF A FIRE ALARM SYSTEM. 1 FACP AND 60 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39559	14041-20000-17990	13053 W DICKENS ST	91604	2	165B161  1038	2385025031	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.14469	-118.41762	PV1.  Install 7.2 kW roof-mounted, utility-interactive PV system.  (2) central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39560	14041-20000-32050	22441 W HARTLAND ST	91307	12	183B101   703	2024029010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.19474	-118.61627	"""0$ permit fees due to senate bill 1222""PV1Install roof-mounted solar array on SFD. Interconnect with 200A MSP. Derating main breaker to 150A.System size: 12.5kW (7.5+5). Grounded system.48 250W pv modules across 5 strings (inv1: 10 and 10+10 combined. inv2: 9+9)."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39561	14041-10000-23310	6447 W WYNKOOP ST	90045	11	102B165   536	4110023010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Issued	08/26/2014 12:00:00 AM	ADDRESS	33.97415	-118.4027	Standard plan, 6KW AC PV1 roof-mounted system including (25) modules and one SMA -6000TL inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39562	19041-20000-06579	843 N STANLEY AVE	90046	5	141B177    56	5527006010	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.08665	-118.35648	NEW 27 KWH ESS FOR EXISTING SFD, INCLUDES NEW 125A LOAD CENTER, 200A LOAD CENTER, AND 2 5KW POWERWALLS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39563	16041-10000-34971	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	11/27/2017 12:00:00 AM		Issued	11/27/2017 12:00:00 AM	ADDRESS	34.06086	-118.27891	PC FOR POWER ONLY TO AN EXISTING HISTORICAL BUILDING. SCOPE INCLUDES ONE NEW FIRE PUMP, ONE NEW EMERGENCY GENERATOR, NEW DISTRIBUTION PANELS, AND NEW CIRCUITS. THIS PERMIT ALSO INCLUDED ALL NEW EQUIPMENTS SHOWN UNDER PLAN CHECK #16041-10001-34971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39564	16041-10001-30965	1000 W 8TH ST	90017	14	129A207    78	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.04866	-118.26309	PLAN CHECK ONLY.  Supplemental PC for changes made to approved set. Changes due to reduction in costs. Changing feeders from copper to aluminum and reducing lenghts. All changes clouded under delta E. Changes where assesed by Mehdi, PC to verify changes and remove this sentence upon appoval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39565	14041-10001-33348	19524 W NORDHOFF ST Suite #3B	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM			PC Approved	02/09/2015 12:00:00 AM	ADDRESS	34.23527	-118.55871	Change to approve set of plan. Changes apply to Title-24 only. (((Full plan check for a medical office change to a dental office.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39566	16041-10001-44612	3237 S LA CIENEGA BLVD BLDG 5.02	90016	10	123B173  1681	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM			PC Approved	05/22/2017 12:00:00 AM	ADDRESS	34.0289	-118.37369	PC FOR CHANGES TO APPROVED SET OF PLANS. ELECTRICAL PERMIT REVISED TO MATCH SCOPE OF WORK. PLAN REVISED TO REMOVE SCOPE OF WORK COMPARED TO ORIGINAL DESIGN. UPDATED FLOOR PLANS AND T24. NO ADDITIONAL WORK DONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39567	11041-20000-02452	9300 N MASON AVE	91311	12	198B109    98	2748022060	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	05/11/2011 12:00:00 AM	ADDRESS	34.23931	-118.57958	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39568	18041-20000-42895	552 N HOBART BLVD	90004	13	141B193   947	5521011030	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Apartment			11/08/2018 12:00:00 AM	02/14/2020 12:00:00 AM		Permit Finaled	07/30/2021 12:00:00 AM	ADDRESS	34.08142	-118.30563	1200A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39569	18041-10000-05961	1335 N LA BREA AVE 1ST FL	90028	4	147B181  1087	5548022069	C2-1-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.09535	-118.34436	CHANGE OF USE FROM RETAIL TO PHYSICAL THERAPY OFFICEPLAN CHECK IS FOR TITLE 24 AS PERMIT WAS OBTAINED ON 18041-10000-03911PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39570	19041-10000-41884	2211 S UNION AVE	90007	1	124-5A201 181	5124001005	C2-1VL-O-HPOZ-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	08/19/2020 12:00:00 AM		Permit Finaled	06/03/2022 12:00:00 AM	ADDRESS	34.03545	-118.28328	ELECTRICAL FULL PLAN CHECK FOR POWER AND ENERGY. NEW 800 AMP SERVICE. TOTAL EFFECTED AREA 13336 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39571	11041-20000-23167	6928 N OWENSMOUTH AVE	91303	3	183B105   755	2138007027	(Q)P-1VL, [Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	05/22/2012 12:00:00 AM	ADDRESS	34.19636	-118.60139	pv system 31.9 kw commercial	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39572	17041-20000-18459	21700 W OXNARD ST suite 360	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.17901	-118.60179	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39573	16041-10000-26041	801 S GRAND AVE	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Issued	12/15/2016 12:00:00 AM	ADDRESS	34.04581	-118.25842	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON THE 1ST FLOOR. SCOPE INCLUDES NEW CANOPY LIGHTS FOR THE 1ST FLOOR OF A COMMERCIAL BUILDING.TOTAL AFFECTED AREA IS 2864 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39574	16041-10002-42441	5800 W SUNSET BLVD STAGES 7&8	90028	13	147A191   236	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	CHANGES TO AN APPROVED SET PLANSCHANGES INCLUDE RELOCATING/ADDING NEW LIGHT FIXTURES, AND FAN COIL UNIT.CHANGES ARE INCLUDED UNDER DELTA 4.IRGINAL PERMIT UNDER = 16041-10000-42441PC FOR POWER AND ENERGY. ADA UPGRADE A T.I. FOR STAGE 7 & 8 FOR A TELEVISION STUDIO. (E)  MEDIUM VOLTAGE SERVICE 4160 V, 2000A. TOTAL AREA 13844 SQ FT.B#16016-10000-24889	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39575	16041-20000-21946	7932 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21486	-118.53476	PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39576	17041-10000-33916	1718 E O ST	90744	15	036B213   242	7426031044	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	33.79288	-118.24211	PC FOR INSTALLATION OF NEW DISPENSER PUMP IN HAZARDOUS LOCATION. SCOPE INCLUDES ONE NEW CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39577	10041-20000-07483	11811 W OLYMPIC BLVD	90025	11	123B149   409	4259023015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM			PC Approved	04/23/2010 12:00:00 AM	PIN	34.03353292	-118.45117088	INTERIOR TENANT IMPROVEMENT TO CREATE THREE NEW CLASSROOMS AND TWO NEW FACULTY OFFICES. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39578	19041-20000-52710	2500 N MANDEVILLE CANYON ROAD	90049	11	141B133   149	4493006002	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	07/22/2020 12:00:00 AM		Permit Finaled	08/24/2021 12:00:00 AM	ADDRESS	34.08296	-118.50308	Plan check for power only 600A service and 5 sub-panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39579	13041-10000-15616	6600 N TOPANGA CANYON BLVD # 1082D	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Expired	07/08/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	"INSTALL 8.5"" X 8'-11"" INTERNALLY ILLUMINATED ""CALIFORNIA PIZZA KITCHEN"" TITLE 24 PLAN CHECK AND PERMIT FOR BAR SIGN"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39580	18041-10002-21765	2827 S SANBORN AVE	90291	11	105A145   276	4227019011	R1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	33.9817	-118.46522	PC FOR ESS IN SFD. SCOPE INCLUDES NEW POWERWALL WITH NEW LOAD CENTER. PV WORK DONE UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39581	18041-10000-16694	11301 W OLYMPIC BLVD 1-45	90064	11	126B153  1060	4260002032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.03819	-118.44181	PLAN CHECK FOR TITLE 24 ONLY FOR CHG OF USE FROM RETAIL TO SMALL COFFEE SHOP (LOWRISE BUILDING) - TOTAL AFFECTED AREA 582 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39582	14041-10000-09428	3174 W LARGA AVE	90039	13	153B209  1216	5436029012	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.11181	-118.25338	P V1 ROOF MOUNTED TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39583	16041-10000-30112	840 W 146TH ST	90247	15	075B197   363	6119023019	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	33.89956	-118.29063	PV1 Solar, roof mount, 3.18 KW (12)modules , (12)inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39584	19041-20000-06343	8040 N CHIMINEAS AVE	91335	12	189B125   236	2102013019	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.2167	-118.52828	Plan check for PV roof mounted system, System size: 6.1kW DC with 20 PV Modules and 20 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39585	12041-10000-23599	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	Change to lighting in the restroom of an existing high-rise office building on the 16th floor.  Plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39586	15041-10000-28402	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	NEW MCCS FOR CONVEYOR SYSTEM LAX TERMINAL 7. PLAN CHECK FOR POWER.  SERVICE LOAD CALCULATIONS PER APPROVED PLAN 13041-10009-10268.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39587	19041-20000-17504	14612 W DEL PLAYA ST LOT 6-pv1	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.24776	-118.45096	pv1install roof mounted pv system sized 3.02KW AC interconnected with msp.  (9) acm rated at 335W each.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39588	17041-10000-08378	2029 S CENTURY PARK EAST #N1100	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for title 24 only in existing space T.I office space. Total area: 4675 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39589	13041-20000-06767	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM			PC Approved	03/20/2013 12:00:00 AM	ADDRESS	34.15777	-118.43065	Plan check for energy only. New restrooms, lockers, etc for new pool. Notre Dame High School.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39590	11041-10000-15528	1545 W WILSHIRE BLVD	90017	1	132A205   202	5142027036	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Issued	09/14/2011 12:00:00 AM	ADDRESS	34.05543	-118.26977	Existing fire alarm system for 10 story building (including basement and roof).  Replacing the fire alarm panel and all initiating devices, which makes it a NEW fire alarm system.   <<<<<PERMIT WAS OBTAINED UNDER A DIFFERENT PCIS#)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39591	18041-10000-44902	5795 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	33.93216	-118.3839	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39592	14041-20000-34609	6033 W CENTURY BLVD 10th Floor-Corridor	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	33.94572	-118.38954	Plan check for energy only. TI to 10th floor corridor of high rise office building. New lighting (incl. emergency). 732sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39593	12041-10000-08602	6303 N OWENSMOUTH AVE 1st fl	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM			PC Approved	04/16/2012 12:00:00 AM	ADDRESS	34.18474	-118.60182	adding luminaires in existing lunch room in office spacesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39594	14041-20002-23953	16600 W ADLON ROAD	91436	5	165B137   518	2291013046	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.14506	-118.49537	CHANGE IN POI. THIS IS NOW GOING TO CONNECT USING A SUPPLY SIDE TAP. PV SYSTEM DESIGN DOES NOT CHANGE. NO PERMIT OFF THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39595	15041-20000-18889	6256 N TOPANGA CANYON BLVD C-1280	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.18496	-118.6049	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR CAVA MEZZE GRILL. FIRST TIME TENANT. 2010 SQFT. BUILDING C SUITE 1280.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39596	18041-10000-09891	5930 W FRANKLIN AVE	90028	13	150A191   192	5586027012	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	34.10506	-118.31873	FULL PLAN CHECK FOR A TI IN AN EXISTING 7 STORY BUILDING. FULL PLAN CHECK FOR POWER AND ENERGY. NEW SERVICE & LOADS WITH (4) 600-AMP SERVICE EACH. BUILDING PERMIT # 18016-10000-12018	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39597	16041-10000-44934	3555 W CASITAS AVE LOT 3	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12092	-118.25705	Plan check for Power 11 buildings SFD live work  2 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 3 of 11Note: Master Application Lot 3 type B,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39598	19041-10000-02448	517 N LUCERNE BLVD	90004	4	141B189  1059	5523015023	R1R3-RG	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Issued	02/06/2019 12:00:00 AM	ADDRESS	34.07947	-118.325	PLAN CHECK FOR AN ADDITION OF ENERGY STORAGE SYSTEM CONSISTING OF 2 POWER WALLS RATED AT 5.8KVA CONNECTED TO AN EXISTING PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39599	15041-20002-01210	10338 N LINDLEY AVE	91326	12	204B125   120	2731010016	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			03/27/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	ADDRESS	34.25844	-118.5272	[[[[3/27/15 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. CHANGES ARE CLOUDED. RELOCATION OF SUB PANEL]]]]PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20.0KW INTERCONNECTED WITH MSP.THIS IS 1  PV DESIGN OF TWO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39600	18041-10000-01907	10250 W SANTA MONICA BLVD #1530	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space ""LACOSTE""  suite 1530 in Westfield Century City."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39601	16041-10000-45546	3760 S CENTINELA AVE	90066	11	114B153  1222	4248032038	P-1, P-1VL, [Q]C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.0047	-118.43412	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures. Total affected area is 5475 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39602	16041-20000-31408	3431 S BENTLEY AVE	90034	5	120B157  1001	4251028018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	10/01/2016 12:00:00 AM	ADDRESS	34.02108	-118.42174	PV1.  Install 3.82 kW DC roof mounted PV system.  Simplified central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39603	15041-10000-33319	12751 W MILLENNIUM A-B	90094	11	102B161  1175	4211033020		West Los Angeles				2756.01	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Issued	10/07/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	New methane mitigation system for new mixed used building. Building A and Building B with common subterranean parking garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39604	11041-10001-08441	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM			PC Approved	09/28/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	DELTA 3 - MODIFICATION TO EXISTING APPROVED SET.  EXISTING 5000 AMP SERVICE. CHANGED LOCATION OF EQUIPMENT AND FEEDER LENGTHS   <<<<TEMPORARY POWER FOR CONSTRUCTION AT BRADLEY TERMINAL WEST CONCOURSE.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39605	10041-10001-17706	6725 W SUNSET BLVD 4TH FLOOR	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM			PC Approved	10/06/2010 12:00:00 AM	ADDRESS	34.09814	-118.33717	TI IN AN EXISTING OFFICE AREA ON THE 4TH FLOOR SUITE #470. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39606	19041-10000-09026	1039 S LA CIENEGA BLVD	90035	5	132B173   489	4332030025	C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.05828	-118.37637	NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 114 FA DEVICES, AND 2 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39607	18041-20000-19906	1313 N VINE ST 1st Floor	90028	13	147A187   357	5546019013	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.09511	-118.32681	Plan check for Title 24 Energy only in existing space. Install 4 new lighting fixtures and tie to existing circkuit. Total area: 2,514 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39608	19041-10000-08162	424 W PICO BLVD 1B	90015	14	126A207   179	5134017004	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Issued	04/11/2019 12:00:00 AM	ADDRESS	34.03913	-118.26523	"FIRST TIME TENANT IN UNIT ""ONYX EAST RETAIL"" SUITE#1B. PLAN CHECK FOR POWER & ENERGY.BULDING PERMIT: 14010-10000-01138"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39609	18041-20000-44574	5865 N FAIRHAVEN AVE	91367	3	177B089   830	2032023008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.17728	-118.65705	PV1.  Install 8.05 kW roof mounted grid tied PV system.  (23) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39610	10041-10000-22683	4457 N VAN NUYS BLVD	91403	2	166-5A151  24	2265011008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00, 1413.01	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.15256	-118.44889	TI IN AN EXISTING RESTAURANT.  PLAN CHECK IS FOR POWER & ENERGY.  (NEW 600 AMP SERVICE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39611	16041-10000-16501	13759 W KINBROOK ST	91342	7	231B153   113	2582007016	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Expired	06/15/2018 12:00:00 AM	ADDRESS	34.32596	-118.43385	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.6KWac.(28)MODULES-CANADIAN SOLAR: CS6P-265P(2)INVERTERS- SOLIS 3.6K-2G-US AND SOLIS-3K-2G-US 3000 WATT	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39612	13041-10000-28663	2415 W OCEAN VIEW AVE	90057	1	135A203   313	5155030003	R3-1	Central	Westlake		YES	2088.02	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.06279	-118.27794	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS NEGATIVELY GROUNDED SYSTEM. SYSTEM SIZE: 8kW DC. 2 STORY HOUSE.(32) HSL60P6-PB-4-250QB(2) SMA AMERICA SB4000TL-US-22-240VAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39613	16041-20000-21956	7946 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21548	-118.53476	PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39614	19041-20000-52839	7361 W FOOTHILL BLVD	91042	7	202-5A199  53	2568009029	(T)MR1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.25114	-118.29256	T24 PLAN CHECK LIGHTS ONLY, TOTAL SQUARE FOOTAGE = 2068 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39615	10041-10000-10546	2323 W OLYMPIC BLVD	90006	1	130-5A201 125	5136015027	C4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.0525	-118.28312	Ti in an existing grocery store. Plan check for T24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39616	14041-10001-16757	9000 W 3RD ST	90048	5	138B169   551	4335014001	(T)(Q)R4-2-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			07/25/2018 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	10/24/2020 12:00:00 AM	ADDRESS	34.07338	-118.38815	"Changes to an approved set of plans. All changes are clouded under delta ""B"", ""1"", ""2,"", ""3"", & ""4"". Changes include relocating loads on panel schedules, updating elevator circuit breaker sizes, adding a new 100A panelboard, making changes to Title 24 calculations, and revising floor power and lighting floor plans."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39617	19041-10000-11699	12660 W JUDD ST	91331	7	213B161   629	2532019021	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.27958	-118.40911	PV1. INSTALLING 7.75 KW DC / 6.79 KWAC SYSTEM SIZE WITH 25 MODULES (SILFAB SLA 310M), INCLUDING (1) INVERTER (SB7.7-1SP-US-40)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39618	17041-20001-01891	18523 W OLDENBURG LANE	91344	12	219B125   140	2601075025	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.29414	-118.53581	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD.15.2kW ungrounded system (2*7.6kW). (54) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39619	17041-10000-06477	311 W PACIFIC COAST HWY #D	90744	15	036B205   998	7421024014	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	33.79211	-118.26673	Plan check for Title 24 only in existing space remodel existing exterior storefront canopy at exterior building facade. Total area: 4,200 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39620	15041-10000-31453	12830 W MILLENNIUM Lot 9-17	90094	11	102B161  1226	4211037008	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	33.97481	-118.41871	PC for T-24 hardscape per 2008 energy code. Total area: 25,709 sq.ft***scope: Lots 9-17, Tract# 60110-01****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39621	17041-10000-28124	5938 N TOBIAS AVE	91411	4	177A151   164	2244005001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.17866	-118.45189	PC FOR ROOF MOUNTER PV ON SFD. TOTAL SYSTEM SIZE 11.04KW/ACSCOPE INCLUDES 32 MODULES	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39622	19041-20000-44007	22317 W BRYANT ST	91304	12	195B101   424	2004021025	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.22728	-118.61362	PV1. INSTALL 10.95 KW DC PV SYSTEM WITH (30) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39623	12041-10000-28747	3000 W 6TH ST 2ND FL	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM			PC Approved	11/29/2012 12:00:00 AM	PIN	34.06351748	-118.28745252	TI TO EXISTING RESTAURANT. 4 STORies. work is for 2ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39624	16041-10000-36322	10250 W SANTA MONICA BLVD 1140	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Zara"" Ste. 1140 in Westfield Century City.  Install new 150KVA transformer and 8 panels with total load over 400A, total effected area: 19,316 sq.ft using Tailored Method."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39625	19041-10001-07778	10450 W WILSHIRE BLVD 1-129	90024	5	135B157   257	4326004181	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	07/23/2020 12:00:00 AM	ADDRESS	34.06558	-118.43053	DELTA 1 CHANGES TO AN APPROVED SET. INSTALLINING NEW FIRE PHONE JACK SYSTEM (71 devices)  AND ITS COMPONENTS FOR FIRE DEPARTMENT COMMUNICATION PER INSPECTOR REQUEST . SCOPE INCLUDES NEW FIRE ALARM CONTROL PANEL (NODE #3). ALL CHANGES ARE CLOUDED UNDER DELTA 1. Original scope:(UPGRADING AN EXISTING ELEVATOR SUPERVISOR CONTROL SYSTEM TO A  FIRE ALARM CONTROL SYSTEM. SCOPE INCLUDES  633 NEW FIRE ALARM DEVICES, 40 EXISTING  AND 21 REPLACED DEVICES, 5 POWER SUPPLIES AND 2 CONTROL PANEL (FACP & NODE) FOR A HIGH RISE APARTMENT BUILDING.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39626	14041-20000-16915	15523 W LEMAC ST	91406	6	189B145   596	2222004007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.21146	-118.47129	PV1Install roof-mounted solar array on SFD. System size: 10 kW(2) SolarEdge SE5000A-US transformerless inverters(40) Renesola JC250M-24/BB pv modules(40) SolarEdge P300 power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39627	15041-20000-41325	3666 N LOADSTONE DR	91403	4	162A147   178	2278010023	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Expired	01/22/2018 12:00:00 AM	ADDRESS	34.13764	-118.45956	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (26)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39628	17041-10000-37696	5918 1/2 N FIGUEROA ST	90042	1	151-5A229 114	5492015028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.11065	-118.19026	PLAN CHECK FOR T24 ONLY, INTERIOR TENANT IMPORVEMENT (1000 SF) AT (E) RETAIL TENANT SPACE FOR WINE STORE. B# 15016-10000-12920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39629	15041-20000-13388	13646 W BURBANK BLVD	91401	4	174B157   612	2344001014	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.17196	-118.4306	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lightign area = 917 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39630	18041-20000-24340	3501 S TROUSDALE PKWY Basement	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.02194	-118.28455	Tenant improvement to (E) commercial office spaces B3 and B7.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39631	11041-20000-24829	10020 N WILBUR AVE	91324	12	204B121   531	2729007007	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2011 12:00:00 AM	12/09/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	ADDRESS	34.25257	-118.54464	Photovoltaic system for single family dwelling.  Connect to new service permitted on applicaion number 11041-20000-25758.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39632	18041-10001-39509	444 S FLOWER ST FL 13	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REPLACEMENT OF 2 LIGHT FIXTURESORIGINAL PERMIT PLAN CHECK FOR T24 ONLY, TI ON RESTROOMS ON (E) 13TH FLOOR. TOLTAL AREA 535 SQ.FT(B# 17016-10000-19727)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39633	17041-10000-13060	5510 W 104TH ST	90045	11	090B173   314	4129034004	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	33.94182	-118.37673	PC for energy only, Outdoor Title-24.  Removing HID fixtures and replacing with New LED. area: 29000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39634	14041-20002-00054	18725 W SHERMAN WAY	91335	3	183B121    99	2118026018	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.20128	-118.54148	Modifications to approved set.  Changes to single line diagram layout.  Additional HVAC loads.  (((Change from retail to adult daycare.  Install new panel, branch circuits, and lighting.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39635	14041-20000-11281	10601 W WILSHIRE BLVD	90024	5	132B153    31	4360031***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			04/29/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.06169	-118.43406	New 800A service for electric vehicle charging station.  Plan check for power only.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
39636	14041-10000-16655	2524 S PACIFIC AVE	90291	11	105A145   184	4227010008	RD1.5-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	33.98241	-118.46777	PLAN CHECK FOR ENERGY ONLY FOR DELI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39637	15041-10000-15630	111 E UNIVERSAL HOLLYWOOD DR 32ND FLR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.13855	-118.36112	Energy plan check for 32nd floor office T.I. Scope includes a completed demolation for the whole floor except exising panels and transformers; all circuits, lighing and receptacles will be new.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39638	16041-10000-10248	5629 1/2 N FIGUEROA ST	90042	1	151-5A229 230	5468033021	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.1095	-118.19335	CHANGE OF USE FROM TAKE OUT RESTURANT TO RESTAURANT WITH OUTDOOR DINING. NO CHANGE IN PARKING ENTERPRISE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39639	14041-10000-15480	9000 N RESEDA BLVD	91324	12	195B125   108	2769001022	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.23439	-118.53589	"T24 FOR CHANGE OF USE FROM RETAIL TO PIZZA ""TAKE OUT"" ONLY RESTAURANT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39640	14041-10001-27218	1522 1/2 E COLON ST	90744	15	036B213   350	7426019017	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	33.79175	-118.24464	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39641	19041-20000-02225	8744 S FIGUEROA ST 1-5	90003	8	096A201   136	6038002043	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	33.9575	-118.28249	Plan check for new fire alarm system, for 3 story building 5 units apartment. Total Fire alarm devices: 26  and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39642	15041-10002-32988	2448 N ENDICOTT ST	90032	14	139-5A235 289	5217017003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.07566	-118.1724	06/06/16Changes to approved set of plans. Changes include reducing the number of modules on the roof-layout from 17 to 12, and changing the inverter from ABB#-3.6-OUTD-S-US-Z-A to an ABB#3.0. New solar system size is 3.18KWdc / 3.00KWac.NOTE: PERMIT PAID UNDER PCIS#15041-90000-32988((((([PC only] PV 1 rooftop solar installaton(17) 265W modules(1) PVI-3.6-OUTDPermit under 15041-90000-32988	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39643	18041-30000-25110	4905 N TOPEKA DR	91356	3	168B121   114	2176007008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM			PC Approved	07/05/2018 12:00:00 AM	ADDRESS	34.15916	-118.54763	Standard PV1 plan check for a 7.6KW AC system, Scope includes (30) modules, (30) Optimizers, and (1) 7.6KW central inverter. The application is for plan check only; Permit fee is paid under 18041-90000-23618.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39644	10041-10000-04524	3000 N VERDUGO ROAD	90065	13	150B213   720	5456012901	PF-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.02	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM	03/11/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.10548	-118.23757	New PV system 39.5 KW installed on the top of a roof of apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39645	19041-20002-29072	2604 S MIDVALE AVE	90064	5	123B157   190	4256031023	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.03605	-118.42633	09-13-2019 Changes to an approved set of plan, changes to an approved set of plan, changes include revised single line diagram to reflect installed conditions and physicle protection. All changes has been clouded as delta A. Plan check only. Fees $ 0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39646	13041-20000-17506	5251 N VINELAND AVE UNIT# 1	91601	2	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			Reviewed by Supervisor	07/22/2013 12:00:00 AM	ADDRESS	34.16639	-118.37064	Plan check for first-time tenant. Unit #1. Cold Stone Creamery	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39647	10041-20000-15756	2142 S PONTIUS AVE	90025	5	126B153   755	4322025041	M2-1VL	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Public Safety Only			08/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.04026	-118.43869	Plan check for new installation of fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39648	11041-10001-20615	972-980 E ELKLAND PL Bldg 2	90291	11	111B145   913	4243002066	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/11/2012 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99903	-118.45916	REPAIRS & HISTORICAL REHABILITATION  / TI OF 17 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.((((((((((((((((((((((((((((((((((((((((addition of 6 new ckts for dettached garage. changes to previously approved set.))))))))))))))))))))))))))))))))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39649	16041-10000-06853	650 S MAIN ST	90014	14	127-5A211 109	5148021011	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Expired	03/29/2018 12:00:00 AM	ADDRESS	34.04409	-118.25091	New FA installation to an italian american museum. (1) FA panel. (45) devices. (1) communication panels	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39650	11041-20000-09160	1420 S VERMONT AVE	90006	1	129B197  1362	5056001057	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	01/12/2012 12:00:00 AM	ADDRESS	34.04562	-118.29142	New 1600A service.  Replace main switchboard and overcurrent protection for each tenants. New ckts, panels, and equipment for laundromat. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39651	12041-10000-13680	817 E 59TH ST	90001	9	105B205    16	6007002028	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM			Reviewed by Supervisor	07/06/2012 12:00:00 AM	ADDRESS	33.98731	-118.26067	REMODEL AND CHANGE USE FROM WAREHOUSE TO CATERING ESTABLISHMENT; SERVICE UPGRADED TO 600A ;NEW PANELBOARDS;STORAGE AREAS ARE FOR FUTURE WORKAT THIS TIME, NEW WORK INCLUDE KITCHEN,OFFICES AND RESTROOMS AND HALLWAY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39652	15041-20001-42574	14006 W LEADWELL ST	91405	2	186B153   592	2216001008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.20374	-118.43811	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. A 3 kWac system addition is being made to a 5 kWac existing system. Addition consists of (1) inverter, (9) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39653	16041-30009-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	07/27/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta ASI-N005. Changes include the addition of new load to existing panels, new panelboards and loads, and a revised lighting floor plan. *****Previous Work Description*****PC FOR CHANGES TO APPROVED SET OF PLANS. UPDATED CIRCUIT DESIGNATION AND MINOR LIGHTING CHANGES. CHANGES NOTED DELTA DCN-057. PC ONLY. PERMIT COVERED UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39654	13041-20000-34357	4159 N STANSBURY AVE	91423	4	165B153   860	2266012017	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.14612	-118.44129	PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING 3 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39655	16041-10000-11347	2867 W SUNSET PL	90005	10	133-5A201  80	5077013022	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Apartment			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.0609	-118.2861	New methane mitigation system with 9 sensors and 5 strobes.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39656	16041-10000-20431	6830 N TOBIAS AVE	91405	6	183B149   697	2219023017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.19482	-118.45186	PV1, rooftop solar installation 10kW AC system,   (36) CS6P-265P     (1) SE10000A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39657	16041-10001-08982	9938 N DEBRA AVE	91343	12	201B137    30	2678015015	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	34.25138	-118.49043	**expedite feePV1 rooftop solar installation 12kW system    (39) SPR327NE-WHT-D     (1) SB7000TL-US   (1) SB5000TL-US   (1) 125A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39658	16041-20000-31998	1550 N WILCOX AVE	90028	13	148-5A187 338	5546013002	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Info Complete	10/06/2016 12:00:00 AM	ADDRESS	34.09947	-118.33087	Plan check for power and energy. Change of use from storage to office. Redoing electrical for space, >400A of new load. 8,677sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39659	11041-10000-08413	2707 W BEVERLY BLVD	90026	13	136-5A203  19	5156020019	C2-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	PIN	34.07021195	-118.27775843	NEW SPRINKLER MONITORING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39660	19041-10001-04659	1147 W 37TH ST 1-5	90007	8	120B197  1108	5040030016	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.0211	-118.29311	Change to an approved set by modifying lighting on the floor plan. All changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39661	12041-10000-06369	1031 W 34TH ST L101	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	PIN	34.02400284	-118.2895744	TI in Dental office unit L101, shell was approved under separtae plan, this plan check for the new tenanat , panel circuits and Title 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39662	09041-30001-16002	6950 S CENTINELA AVE	90230	11	105B165   473	4220014049	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM			PC Approved	04/01/2010 12:00:00 AM	ADDRESS	33.98378	-118.39957	Plan check only.  Revision to approved plans. All changes are clouded on plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39663	16041-20004-02777	620 S VIRGIL AVE	90005	10	135A201   140	5077007029	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Apartment			06/19/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.06288	-118.28683	6.19.2017 - Plan check for modifications to approved set. Remove some devices. Relocate some devices. Changes clouded delta 5.======Revisions to approved set of plans.  Additional monitor modules, removal of devices from tenant lease space, and miscellaneous changes.  Approval for delta-4 revisions only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39664	19041-10001-27391	6502 N VAN NUYS BLVD	91401	6	180B149   597	2237014006	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			Corrections Issued	08/13/2019 12:00:00 AM	ADDRESS	34.18884	-118.44845	***Expedite Fees***PV2. NEW ROOFTOP COMMERCIAL SOLAR SYSTEM CONSIST OF 168 MODULES (TRINA SOLAR 360), 2 CENTRAL INVERTERS ( SUNNY TRIPOWER 30KW EACH) AND ONE 75KVA TRANSFORMER. SYSTEM SIZE IS 60.48KWdc AND 60KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39665	18041-10000-37516	3640 W WILSHIRE BLVD #150	90010	10	132B193    62	5093019018	(T)(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	34.06145	-118.30446	FIRST TIME TENANT. PLAN CHECK FOR POWER AND ENERGY. 1624 SQR FT.PLAN CHECK ONLY. ELECTRICAL PERMIT WAS ISSUED UNDER 18041-10000-26244.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39666	16041-10000-12713	1215 E PACIFIC COAST HWY	90744	15	036B209   629	7426016024	[Q]C1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM			PC Approved	04/12/2016 12:00:00 AM	ADDRESS	33.79111	-118.24826	PC FOR ENERGY ONLY. CHANGE OF USE FROM RESTAURANT TO RETAIL TOTAL AREA 3955 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39667	16041-20002-26766	401 S KINGSLEY DR 1-84	90020	10	135B193   432	5503010025	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.06692	-118.30302	changes to an approved set of plans.  changes include downsize (1) inverter to 8kw and reconnect to msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39668	14041-10005-27847	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	"5/3/2016Change to the approved set of plan. changes includes relocation of temporary loads and 1600A distribution board(3ldsk). the loads connecting to existing 600A panel. All changes noted delta 6 revision on plans02/11/2016Changes To an approved set of plans. Changes include the connection of temporary load. The loads connecting to ""MS2"" are in (E) panels ""EDS"", ""DSBG"" and DSBG-A"". 8/12/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  TEMPORARY POWER FOR BAGGAGE HANDLING.7/24/2015 PLAN CHECK FOR CHANGES TO SET OF PLANS DELTA 1 AND DELTA 2. RESHUFFLING OF LOADS AND RELOCATION OF PANELS. NO NEW LOADS HAVE BEEN ADDED. ((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX TERMINAL 1. CHANGING OF THE POWER DISTRIBUITION SYSTEM AND LIGHTING.))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39669	17041-10000-10739	10400 N ZELZAH AVE	91326	12	204B129    52	2733001017	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.25866	-118.52314	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 124,665.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39670	17041-20000-35370	14478 W VENTURA BLVD Unit# 2	91403	4	166-5A151 155	2266001025	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	PIN	34.15052233	-118.44817951	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO CONVERT RETAIL TO TAKE OUT RESTAURANT. 500 SQFT. BUILDING PERMIT : 17026-30000-00359	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39671	17041-10000-18084	6303 N OWENSMOUTH AVE 6TH FLR	91367	3	177B105   123	2146029016	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.18474	-118.60182	Plan check for power and Title 24.  T.I. to 6th floor of existing office highrise building.  New lighting and receptacles.  New cord reel receptacles.  Total area = 20,057 sq ft.       Building permit #17016-10000-14281	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39672	14041-10000-09419	6123 S HARCOURT AVE	90043	8	105B181   890	4004025018	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	33.98385	-118.3408	PV1 1.5KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(6)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39673	14041-20000-17502	20870 W VENTURA BLVD	91364	3	171B109   105	2166028***	RA-1, RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Issued	06/27/2014 12:00:00 AM	ADDRESS	34.16612	-118.58755	TI to (E) church hall lighting system.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39674	10041-20000-24016	1 S LMU DR Basement-1st floor	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	T.I. to existing building.  Install general/emergency in partial of  basement and first floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39675	19041-10000-12108	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	08/03/2020 12:00:00 AM	ADDRESS	33.79173	-118.23549	***Application Withdrawn per applicant's request. Change of Contractor. New Permit#: 19041-10000-44347***<<<Power plan check for new 800-Amp equipment with new ckts located in a classified area (refinery ).>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39676	17041-10000-28449	660 S FIGUEROA ST #2050	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	Plan check for Title 24 only in existing space T.I. office high-rise. Total area: 6,295 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39677	17041-20000-32569	2408 E RIVERDALE AVE	90031	13	145-5A217 197	5445016015	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.09189	-118.23357	PV1.  Install 5.7 kW roof mounted grid tied PV system.  (19) modules with (1) 5 kW rated string inverter.  13.5 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39678	19041-10000-01868	6250 W FOREST LAWN DR	90068	4	165B189    22	5581001004	RE40-1	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Issued	01/16/2019 12:00:00 AM	ADDRESS	34.15138	-118.3265	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39679	11041-20000-11376	1902 E MARENGO ST	90033	14	132A223    33	5201016003	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Info Complete	10/18/2011 12:00:00 AM	ADDRESS	34.05756	-118.21009	Plan check power and energy for core and shell, new commercial building with 3 levels (1st floor - retail/restaurants, 2nd & 3rd floor -  medical offices). Site in Methane Buffer Zone, no mitigation required according to methane report. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39680	15041-10000-34531	7230 N CANOGA AVE	91303	3	186B105   631	2111029001	(T)(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.20217	-118.59751	Plan check for power only.  T.I. to retail first time tenant.  New lighting, AC unit, and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39681	14041-20000-00664	20951 W VANOWEN ST	91303	3	183B109   900	2138029024	[Q]C2-1VL	South Valley		Canoga Park		1349.03	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.19393	-118.59008	Change to lighting in a non-classified area in an existing commercial space.  Load is 325 amps per the engineer.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39682	19041-30000-12915	2049 S CENTURY PARK EAST Suite 2525	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,015 sq. ft.Note: Building permit has been issued under 19016-10000-05768	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39683	13041-10000-27266	8659 W WENTWORTH ST PV1	91040	7	207B189   116	2551043061	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.26716	-118.32207	PV1- Plan check for new roof mounted 6.45KW photovoltaic system using Enphase M215 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39684	18041-20000-45471	10746 N BAILE AVE	91311	12	207B117   493	2708027027	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.26576	-118.56243	Plan check for PV roof mounted system, system size: 10.23kW DC, 9.554KW AC with 31 PV Modules and 1 inverter(10.0kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39685	13041-20000-07707	147 N LARCHMONT BLVD	90004	4	138B189   757	5515019020	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.07437	-118.32384	T-24 lighting plan check for a remodeled space.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39686	15041-10001-43636	7870 N VAN NUYS BLVD	91402	6	189B149   645	2212028013	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM	ADDRESS	34.21426	-118.44738	PC for changing wiring from 3 wire to 4 wire system. Provided new wire notes. all changes clouded delta 5 on plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39687	14041-10001-30036	12824 W LORNE ST	91605	2	189B161   211	2305008023	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2014 12:00:00 AM			PC Approved	10/30/2014 12:00:00 AM	ADDRESS	34.21762	-118.41286	Plan check only for express permit issued under 14041-70000-30036.   $0 plan check submittal fee is due to Senate Bill SB-1222.(((Installation of a 4.4 kw. photovoltic system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39688	10041-10000-16022	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Expired	06/01/2022 12:00:00 AM	ADDRESS	34.02224	-118.28008	Ti in a restroom. Plan check for T24. (Permit is for 2 X-Former and 4 panels. Plan check may be required base on the field inspection.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39689	19041-10000-10662	818 N HILL ST	90012	1	135A215   289	5408032026	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.06338	-118.23906	Remove HID fixtures and replace with new LED fixtures (Outdoor Only), - T/24 only Total sq. ft. 3900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39690	13041-10000-33013	13930 N BREGER AVE	91342	7	228B157    24	2582011019	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.32591	-118.43034	PV1, Install 10 kw DC roof-mounted solar array for a 2 story house, interconnect with the main service panel.(2)Transformered inverter(s): Fronius IG Plus A 7.5. (40) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39691	17041-10000-42742	981 S ELDEN AVE 1-16	90006	1	129B197   158	5076003014	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Apartment			11/28/2017 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.05302	-118.28797	PC FOR POWER ONLY FOR AN APARTMENT BUILDING. SCOPE INCLUDES ADDING A NEW 600A 120/240V SERVICE/DISTRIBUTION BOARD, TWO NEW 100A SUBPANELS, AND ONE NEW 200A DISTRIBUTION SECTION. CONVERT TWO (2) BEDRM UNITS INTO TWO (1) BEDRM UNITS AND TWO SINGLE RM UNITS WITHIN AN EXIST APT BLDG. B#17016-20000-17576	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39692	18041-20000-40068	245 N TOYOPA DR	90272	11	123B129   686	4411024027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.03161	-118.52	Plan check for a PV1 roof-mounted PV system. System size is 13.2 kWdc/10.56 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (40) modules.Fees $51.07 Due to California Senate Bill 1222 And AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39693	17041-20000-12796	535 N EDINBURGH AVE	90048	5	141B177  1006	5527018005	R1-1	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.08112	-118.36386	PV1. ROOFMOUNTED SOLAR SYSTEM. SYTEM SIZE: 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39694	13041-10000-13957	10228 N VARIEL AVE UNIT #10	91311	12	204B105   396	2747004***	(Q)RD1.5-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.25599	-118.59279	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD (CONDOMINIUM) UNIT 10. SYSTEM SIZE IS 5.39 KW, 22 MODULES IN TWO STRINGS. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: SMA # SUNNY BOY SB 5000US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39695	18041-10000-47353	606 N WESTERN AVE	90004	13	141B193   857	5521002005	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.08193	-118.30887	TENANT IMPROVEMENT IN FURNITURE STORENEW CIRCUITS AND LIGHTING SYSTEMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39696	17041-20000-21137	360 E SUNSET AVE	90291	11	109-5A143  31	4286007025	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	PIN	33.99569306	-118.4734634	Service upgrade for (E) commercial building - (N) 600 A 120/240V 3ph-4w service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39697	16041-10000-41366	734 S ALAMEDA ST	90021	14	123A215   225	5166032037	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.03279	-118.2373	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING TO MORE ENERGY EFFICIENT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39698	19041-20000-50834	11999 W SAN VICENTE BLVD 201	90049	11	129B141   174	4404025029	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM			PC Info Complete	12/10/2019 12:00:00 AM	ADDRESS	34.05246	-118.47261	Plan check for Title 24 only, new lighting and associated load, Total area: 1319 sq ft.B#19016-40000-35418	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39699	17041-10000-29849	17255 W ROSCOE BLVD	91325	12	192B133   249	2690017114	C2-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.22128	-118.5093	REPLACE LIGHTING FOR LED TYPE. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39700	19041-20000-27726	12403 W WASHINGTON PL	90066	11	111B157   696	4235018026	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Info Complete	07/18/2019 12:00:00 AM	ADDRESS	33.99957	-118.43071	Power and energy plan check per applicant's request for existing space tenant improvement. Total area: 2134 sq ft. B#19016-20000-20455	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39701	18041-10000-32496	4835 S SEPULVEDA BLVD	90230	11	111B165   200	4215031037	C2-1, R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	04/18/2019 12:00:00 AM		Issued	04/18/2019 12:00:00 AM	ADDRESS	34.00052	-118.40294	FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW MC DONALD - NEW SERVICE AT 1000A WITH TOTAL AFFECTED AREA = 4956 SF == BLDG PERMIT: 18016-10000-27448	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39702	14041-20001-25603	1480 N ARMADALE AVE	90042	14	157-5A223  62	5476020005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.12454	-118.21136	Expedited plan check per applicant request.  PV1.  Install 7.848 kW roof-mounted, utility-interactive PV system.  (2) 3.8 kW transformerless inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39703	14041-10000-04595	338 S WESTERN AVE Suite K-Suite M	90020	10	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			Reviewed by Supervisor	03/06/2014 12:00:00 AM	ADDRESS	34.06777	-118.30889	FIRST TIME TENANTS FOR AN EXISTING 1600A SERVICE. PLAN CHECK FOR POWER AND ENERGY.  ( SQFT WAS NOT INCLUDED IN THE FEES, ADD IT TO THE FINAL FEES)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39704	16041-30000-37174	10950 S CENTRAL AVE	90059	15	088-5A211 269	6070006005	MR1-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.93574	-118.25399	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39705	17041-20001-34516	24052 W BESSEMER ST	91367	3	177B089   433	2045006014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.18133	-118.65127	01/03/2018 Changes to an approved set of plans. All changes have been clouded. A new distribution board has been added. *****Previous Work Description*****Plan check for AC coupled battery backup system for SFD (w/existing solar on site).(1) 5kW Tesla Powerwall 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39706	19041-10000-10178	950 E 3RD ST	90013	14	127-5A217 112	5163016017	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Issued	04/08/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	T-24 PLAN CHECK OR CHANGE OF USE A PORTION OF (E) RETAIL TO MANUFACTURING (COFFEE ROASTING) AND TENANT IMPROVEMENT TO  AN EXISTING 2,348 RETAIL SPACE. TOTAL CONNECTED LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39707	18041-20000-01847	333 S HOPE ST 25th Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 only. Project site is an existing commercial hig-rise building. Project scope is a tenant improvement. Total lighting area = 1,794 sq. ft.Note: Building application has been generated under 18016-10000-00313	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39708	09041-10001-09281	20700 S DENKER AVE	90501	15	054B193   283	7351020017	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM	04/05/2010 12:00:00 AM		Permit Finaled	06/14/2010 12:00:00 AM	ADDRESS	33.84318	-118.30379	Supplemental from previous approved plans.  Per applicant, replace 800amp switchboard and all changes indicated by cloud as shown on plans.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39709	17041-20000-42488	1645 S 6TH AVE	90019	10	126B189   500	5072016010	RD2-1XL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	PIN	34.04227248	-118.32398014	Plan check for a PV1 roof-mounted PV system. System size is 3.5 kWac and consists of (10) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39710	13041-10000-25207	225 S LINCOLN BLVD	90291	11	111B145   529	4240019061	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	04/01/2021 12:00:00 AM	ADDRESS	34.00183	-118.46926	"permit to be pulled at EPC counter only. pc for energy only. TI TO EXISTING JUICE BAR DEPARTMENT. 1 STORY. EMERGENCY LIGHTING ""COMPLY WITH DEPARTMENT ORDER effective date07/28/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39711	18041-10000-38345	765 E PICO BLVD #1	90021	14	123A211   102	5132012020	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.03196	-118.25187	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39712	16041-20000-43870	15835 W NAPA ST	91343	12	192B141    51	2673007042	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.22664	-118.47777	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39713	13041-10001-24608	8936 N ODESSA AVE	91343	12	195B137   252	2688009004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.23329	-118.49154	CHANGES TO APPROVED SET OF PLANS: from rec250 to ET-P660255WB modules. Senate Bill No.1222 Fee cap reached on original application, thus supplemental fee is $0.PV1 6.04KWAC 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 28) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39714	16041-10000-01886	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Expired	05/18/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	#Package 8 of the Terminal 7 and Terminal 8 LAWA.Add new branch circuits to existing panels, add new motors (mechanical equipments), add 1 <200A panel. Total area for T-24 70,000  sq.ft.All other relectrical equipments are Existing and approved under Package 1-7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39715	15041-20001-40832	13204 N AZORES AVE	91342	7	225B157   786	2512012040	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/28/2015 12:00:00 AM	ADDRESS	34.31029	-118.42255	EXPEDITE FEE PER APPLICANTPV1, roof mounted solar 6kW AC, interconnect with (E) 200A service.(26) hanhwa q cell Q PRO G4 260(1) SE6000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39716	06041-10006-31275	308 E 9TH ST	90015	14	126A211   217	5145016022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM			Reviewed by Supervisor	01/15/2010 12:00:00 AM	ADDRESS	34.0397	-118.25323	Supplemental is for changes to previously approved.  New changes include new panel sections, relocation of service / distribution gear, new panels, and relocation of ckts.  P/C is for Power only :: Revisions to approved set of plans-placing pull-sections side by side; Ms is connectred to PS-1 with feeders not bus; added  600 section and 2 ea panelboards and circuits	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39717	13041-20000-25681	11835 N EDDLESTON DR	91326	12	216B125   181	2870023041	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	34.2883	-118.53449	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12.54KW. 44 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39718	17041-10000-43215	1375 E 6TH ST Bldg A	90021	14	126A217    90	5164008021	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.03838	-118.23365	REPLACE EXISTING FIXTURES WITH LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39719	17041-10000-31777	5517 W VENICE BLVD	90019	10	126B177   253	5069027007	C2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.04421	-118.3591	PC for new Fire Alarm system with one FA panel, two annunciator and 36 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39720	19041-20000-16303	2576 N BASIL LANE	90077	5	154-5A151 189	4379005***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.1185	-118.44782	Plan check for Battery back up system, Battery size 13.5KWh install into existing PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39721	09041-30001-24800	9860 W NATIONAL BLVD	90034	5	123B165   967	4311005014	C2-1, P-1	West Los Angeles	West Los Angeles	Westside	YES	2698.00	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM			PC Info Complete	07/08/2010 12:00:00 AM	ADDRESS	34.03074	-118.40162	"Changes to Approved plans according to ""Bulletin / Delta 3"".    No new load or lights added.  Changes to the home runs to the light fixtures only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39722	13041-20000-34362	4118 N MURIETTA AVE	91423	4	165B153  1025	2266024028	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.14483	-118.43659	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. 2 STRINGS/INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39723	14041-20000-01427	10435 W SANTA MONICA BLVD	90024	5	132B157   686	4326032031	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	PIN	34.05697834	-118.42553713	T24 FOR EXISTING OFFICE SPACE. TOTAL SQRFT 5100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39724	17041-20000-04963	241 N LAKE ST	90026	13	136-5A205 103	5157018062	R4-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			02/21/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.06936	-118.27013	Plan check for power and energy. New 4 story, 41-unit apartment building, over one level enclosed parking garage and one level basement enclosed parking garage. 1,000A service. T24 area: indoor - 17,980sqft; outdoor - 3,857sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39725	18041-10000-29969	19750 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	33.85128	-118.29031	0PC FOR T24 FOR LOBBY AND RESTOOMS REMODEL  ON 1ST AND 2ND FLOOR. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 6696 SQ.FT (INDOOR+OUTDOORS)B#18016-10000-25413	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39726	17041-20001-30501	6815 N CANOGA AVE	91303	3	183B105   939	2138011026	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM			Reviewed by Supervisor	08/14/2018 12:00:00 AM	PIN	34.1940675	-118.59784166	Original submitted set of plans lost - submittal fees charged on hourly basis for recheck of plans.(((PLANCHECK FOR POWER AND ENERGY.  PROPOSED MIX-USE 6 STORY 150 UNIT APARTMENT OVER 2 LEVEL BASEMENT BELOW.BUILDING PERMIT # 16010-20000-06384)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39727	14041-10000-36001	201 N LOS ANGELES ST Unit #16	90012	14	130-5A213   3	5161014901	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Expired	06/21/2016 12:00:00 AM	ADDRESS	34.0529	-118.24156	Plan check for Title-24 only. T.I. existing tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39728	16041-20000-41554	928 N WESTERN AVE	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	33.75089	-118.30884	Plan check for Title 24 only. Project site is an existing tenant space of a commercial building. Project scope is a change of use from office to massage parlor/tenant improvement. Total lighting area = 2,775 sq. ft.Note: Building application has been generated under 16016-20000-19366	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39729	13041-10000-30861	19913 W MARTHA ST	91367	3	174B113   291	2153017019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/27/2013 12:00:00 AM	ADDRESS	34.17348	-118.56639	PV1, Install 4.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 17 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39730	17041-10002-26270	1016 N ALVARADO ST	90026	13	139-5A207 154	5404003024	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.07681	-118.26375	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDES RELCATION OF EXITING LIGHTING CONTROLS AND LAYOU CHANGES ONLY - NUMBER OF FIXTURES STAY THE SAME. ORIGINAL APPLICATION 17041-10000-26270TITLE 24 PLAN CHECK FOR TI (CHANGE OF USE FROM AUTO REPAIR GARAGE TO HEALTH CLUB(GYM) (2,472 SF) / RETAIL (1,379 SF) / AND OFFICE (3,516 SF). TOTAL AFFECTED AREA = 5903 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39731	18041-10000-17284	888 W 7TH ST #100	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Issued	10/22/2018 12:00:00 AM	ADDRESS	34.04915	-118.25976	PC FOR EXISTING BANK OF AMERICA INTERIOR TI IN A HIGH RISE. TOTAL AFFECTED AREA 4168 SQ.FTSCOPE INCLUDES NEW LIGHTS, CIRCUITS AND RECEPTACLES. B# 18016-10000-14701	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39732	19041-20000-03389	20833 W SPRUCE CIR	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.29534	-118.58798	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39733	11041-20001-08781	8029 W SUNSET BLVD	90046	5	147B177   993	5551017043	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM	05/18/2011 12:00:00 AM		Permit Finaled	06/20/2011 12:00:00 AM	ADDRESS	34.09817	-118.36487	RESTAURANT TENANT IMPROVEMENT - SUPPLEMENTAL APPLICATION. T24 ENERGY LIGHTING. PERMIT FOR NEW LIGHT FIXTURES ON EXISTING CIRCUITS. EXISTING EXIT SIGNS AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39734	17041-10000-26739	725 S FIGUEROA ST STE 1010	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR OFFICE TI. T24 ENERGY ONLY. SMALL BREAK AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39735	13041-20001-22205	11201 N DEMPSEY AVE	91344	12	210B141   334	2666028005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.27368	-118.47718	((EXPEDITE FEE))PV1 TRANSFORMERLESS SYSTEM WITH SOLAR OPTIMIZER. TOTAL SYSTEM SIZE 4.59 KW. 17 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39736	16041-20001-42760	3441 N CARIBETH DR	91436	5	159B137   204	2293010012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.13391	-118.49303	Expedited plan check fee per applicant request. PV1.  Install 12.7 kW roof mounted grid tied PV system.  (41) modules with AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39737	13041-20000-18816	19527 W VENTURA BLVD	91356	3	174B117   257	2164013007	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.17296	-118.55895	RENOVATION OF PIZZA RESTAURANT. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 1380 SQ FT. PERMIT TO BE ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39738	13041-10000-16202	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	New ti for beverly center, 7th floor space 796, lighting and emergency lighting. title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39739	14041-20000-20086	6920 N BIANCA AVE	91406	6	183B129   713	2229006022	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.19638	-118.51287	Standard plan: 7.8KW roof-mounted system with (2) Power One PVI-3.0-OUTD inverters and (30) Rec Solar REC260 modules connecting through a 100Amp load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39740	19041-10000-48425	740 W 182ND ST	90248	15	063B201   114	6121020009	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM			Reviewed by Supervisor	12/05/2019 12:00:00 AM	ADDRESS	33.86917	-118.28665	"Replacing existing lights in an existing ""Home Depot"" with new lights. Affected area:137,605 SFT (INDOOR) + 19,130 SFT (OUTDOOR) = Total 156,735 SFT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39741	15041-10001-24665	1633 N LA BREA AVE 1-180	90046	4	147B181  1177	5548008***	C4-1VL-SN, R4-1VL	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	ADDRESS	34.10058	-118.34527	12/28/15CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1. SCOPE OF WORK INCLUDES CHANGING FIXTURE MODEL NUMBER. (((PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT RETAIL STORE.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39742	13041-10000-25957	6255 W SUNSET BLVD # 705	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	T.I. IN (E) 1230 SQFT OFFICE SPACE - ADD NEW NON-BEARING PARTITION WALLS, DOORS, CEILING AND FINISHES.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39743	15041-20002-33911	16890 W ENCINO HILLS DR	91436	5	162B133   271	2287016067	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	34.13759	-118.50105	[[[ 11/4/15 CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. PLANCHECK ONLY. CHANGES THE MODULES FROM HANWA 265 TO SOLARWORLD 255]]]PV1, roof mounted solar panel 14.31 kW DC, (54) modules: Q.PRO BFR-G3 265, (2) Inverters: SB6000TL-US, (2) combiner boxesNote: Fees $0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39744	17041-20002-41529	23317 W SCHOENBORN ST	91304	12	192B093   321	2005011011	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.22052	-118.63547	03/13/2018 Change of work description. Plan check for a PV1 roof-mounted PV system. System size is 8.71 kWdc and consists of (1) inverter and (26) modules.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (26) modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39745	10041-20000-09237	1741 N IVAR AVE	90028	13	148-5A187  57	5546005019	C4-2D-SN	Central	Hollywood	Hollywood United		1902.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	10/15/2010 12:00:00 AM	ADDRESS	34.10278	-118.32831	TI FOR OFFICE BUILDING DOING LIGHTING AND POWER. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39746	14041-20000-05586	723 W ANGELUS PL	90291	11	108B149  1271	4237014004	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	PIN	33.98998752	-118.45482645	pv1 single family dwelling. total system size 5kw ac using transformer inverter. 3 strings/ inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39747	19041-20000-46820	19540 W VICTORY BLVD	91335	3	180B117   901	2132015002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.18634	-118.55962	Plan check for PV roof mounted and battery system, PV system size: 8.125KW DC, 7.41KW AC CEC with 25 PV Modules, 1 inverter(7.6KW) with LG Battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39748	13041-10000-14023	380 WORLD WAY Space T51B	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	12/21/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	pc for power and energy. retail STORE FRONT ONLY (Starbucks).  1st time TENANT IMPROVEMENT in LAX (Space T51B).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39749	17041-20002-16993	9408-9410 N OWENSMOUTH AVE	91311	12	198B105    66	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	PIN	34.2410613	-118.60115579	11/30/17changes to an appropved set of plans.  changes noted delta 1.  changes include alteration to existing lighting system, revised energy calculations.  plan check for energy indoor only.  (((PC for power and energy for TI for electronic manufacturing facility in second floor of building. PC includes check for new 3000 A 277/480 service, new electronic manufacturing equipment, spray booth, outdoor compressor and power supply units for equipment. Total affected area is 15369 sqft.Bulding # 17016 20000 05741)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39750	16041-20000-14161	8515 S KANSAS AVE	90044	8	097-5A197 289	6033014039	[Q]C2-1, [Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	33.96038	-118.2942	Plan check for power and energy. Project site is a new 3-story high school. Total lighting area = 72,320 sq. ft.Note: Building application has been created under 16010-10000-01421	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39751	16041-10000-00670	11518 W PICO BLVD	90064	11	123B153   492	4260034038	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.03314	-118.44243	PC FOR A NEW FIRE ALARM SYSTEM TO AN EXISTING ELEMENTARY SCHOOL. SCOPE INCLUDES 1 NEW FIRE ALARM PANEL, AND 23 FIRE ALARM DEVICES ON FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39752	15041-20000-12427	21335 W STANWELL ST	91311	12	207B105   417	2706029003	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Expired	05/22/2017 12:00:00 AM	ADDRESS	34.2623	-118.5965	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (32) modules, and (2) combiner boxes. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39753	14041-10000-14694	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	10/27/2015 12:00:00 AM		Issued	10/27/2015 12:00:00 AM	ADDRESS	33.74512	-118.26099	PC FOR POWER. REPLACE 3 MEDUIM VOLTAGE EXISITING MOTORS, AND 2 MCC WITH SOME NEW MOTORS. FOR PORT OF LA, TERMINAL ISLAND.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39754	13041-10001-10789	2000 S BUTLER AVE	90025	11	126B149   959	4261035003	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.03919	-118.44625	INSTALLING PV SYSTEM TO SINGLE FAMILY DWELLING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39755	14041-10000-07294	6600 N TOPANGA CANYON BLVD #68	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	Ti for a shoe store. EPC is for T24 & emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39756	14041-20000-11533	3012 W EFFIE ST	90026	13	144A205   192	5425016006	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.08958	-118.26998	PV1 Install roof-mounted solar array on SFD. System size: 3kW(1) Solar Edge 3000 transformerless inverter(10) REC260PE pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39757	18041-10000-00432	1349 S CHANNING ST	90021	14	121-5A215 212	5166026005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.02591	-118.23825	OFFICE ADDITION TO EXISTING TYPE III-A MANUFACTURING BUILDING.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39758	14041-10000-06371	1114 E 8TH ST #107	90021	14	124-5A213 367	5146019007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.03501	-118.24516	T24, REMOVING HID LIGHT FIXTURES WITH NEW FLORESCENT FIXTURS. TOTAL AREA 725 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39759	12041-20000-16599	333 S HOPE ST 11th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	T-24 and emergency lighting plan check for a portion of the 11th floor corridor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39760	11041-20000-05448	11645 W WILSHIRE BLVD 8th floor	90049	11	129B145   489	4265001036	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	PIN	34.0501741	-118.46033667	T.I. to existing high rise building.  Install general/emergency lighting 8th floor in corridor area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39761	16041-10000-15287	2215 E ALCAZAR ST	90033	14	135A225    11	5202001004	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM			PC Info Complete	06/09/2016 12:00:00 AM	ADDRESS	34.06357	-118.20153	PROPOSED DAYCARE FACILITIES. (N)1600A DISTRIBUTION BOARD, CONNECTED LOAD > 400A.TOTAL AREA 20,515 SQ. FT (INDOOR + OUTDOOR)Note: Pre-made check. Plan checker to verify fees. B# 14010-10000-01873	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39762	11041-20000-08085	8900 N DE SOTO AVE	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM			PC Info Complete	04/21/2011 12:00:00 AM	ADDRESS	34.23162	-118.58832	New outdoor lighting. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39763	10041-20000-05438	16403 W VENTURA BLVD UNIT D	91436	5	168B137   347	2260009043	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	04/07/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	34.15747	-118.49025	Restaurant t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39764	18041-20000-35054	5708 N COMANCHE AVE	91367	3	174B113   169	2151009006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.17492	-118.57208	Plan check for PV roof mounted system, system size: 7.44kW with 31 PV modules  and 31 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39765	14041-10000-35722	5050 N VINELAND AVE	91601	2	171B173   981	2419003001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM			PC Info Complete	01/13/2015 12:00:00 AM	ADDRESS	34.16247	-118.37009	Plan check for Title 24 only. Project scope is a tenant improvement to an existing commercial space. Total lighting area = 1,369 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39766	18041-10000-33938	7747 W APPERSON ST	91042	7	204B193   618	2558006026	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.25613	-118.3017	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39767	12041-10000-02513	400 W WORLD WAY 4H	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	03/28/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK T24 ENERGY/EMERGENCY  FOR TI OF EXISTING STORE TERMINAL 4 SPACE #4H	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39768	19041-20001-20709	5030 N CANOGA AVE	91364	3	168B105    45	2167009001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.16045	-118.59601	07/12/2019 Changes to an approved set of plans. (1) load center has been removed. Plan set has been updated to reflect change.*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 9.36 kWdc/8.19 kWac and consists of (26) AC PV modules and (2) load centers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39769	16041-10000-08642	6600 N TOPANGA CANYON BLVD Suite 89	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Title 24 plan check only.  Total area = 4,727 sq. ft.T.I. to existing commercial space.  New retail clothing store.  Existing subpanels to remain with new lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39770	15041-10000-23072	1327 E 21ST ST	90011	9	120A211   274	5119001021	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Expired	08/16/2017 12:00:00 AM	ADDRESS	34.02205	-118.25153	PV2,  3KW roof-mounted system with (16) ES-Series modules ES-190 and (1) Sunny Boy 3000-US  inverter connecting through the line side.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39771	16041-20000-17624	603 S GAFFEY ST	90731	15	015B197   364	7451035025	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM			PC Approved	09/02/2016 12:00:00 AM	ADDRESS	33.73862	-118.29255	TI for a Sherwin Williams Paint retail store.  Plan check for energy - 229 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39772	11041-10000-09954	751 N ECHO PARK AVE	90026	13	138A209    47	5404015900	OS-1XL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.07242	-118.25998	AT THE ECHO PARK LAKE, REPLACEMENT OF FOUNTAIN PUMPS, STORM  PUMPS AND NEW OUT SIDE LUMINAIRES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39773	16041-10005-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	09/06/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	CHANGES TO APPROVED SET NOTED AS DELTA-9.  PC ONLY. PERMIT ISSUED UNDER MASTER.  SCOPE:(1) UPDATE SOME OF THE FEEDER SIZES TO COMPLY WITH 2016 CEC. MODIFICATION TO VOLTAGE DROP APPROVED AND SIGNED BY INSPECTION DUE TO VOLTAGE DROP RESTRICTIONS. (2) REDUCE BREAKER SIZE -- REFER TO CLOUDED DELTA 9 ON THE PLAN(3) REMOVE WATER HEATER LOAD FROM PANEL MSB(4) REVISE FEEDER TAG NUMBERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39774	17041-10000-19494	678 S ARDMORE AVE	90005	10	132B193   214	5094001002	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	01/18/2022 12:00:00 AM	ADDRESS	34.06063	-118.30186	PC for power and energy for 125 unit 5 story apartment addition on top of an existing 2 story parking structure. Scope inlcudes new 480/277 V 2000 A service/distribution board, new panels, new lights, and new circuits. Total affected area is 121,886 Sq. Ft.         Building #17014-10000-00073.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39775	18041-10000-47415	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/14/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	ADDING A NEW PANEL FOR MOTOR CIRCUITS FOR A NEW CONCERT RIG IN NORTH END OF STADIUM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39776	16041-20000-44981	7183 WORLD WAY WEST	90045	11	090B157   100	4117032900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	33.94557	-118.41975	Portable crusher plant at LAX for temporary construction.  New 1200A MCC and associated motor loads/pre-assembled trailer.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39777	15041-20000-24725	18930 W SHERMAN WAY	91335	3	183B121  1199	2129035***	(Q)RD1.5-1-RIO, (Q)RD3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Expired	08/25/2017 12:00:00 AM	ADDRESS	34.20079	-118.54596	Plan check for PV roof mounted system. System size: 6.0kW with 11 modules and 2 inverters(3.0&3.0kW) Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39778	14041-10003-16357	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Apartment			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	03/30/2016CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES ON DELTA 4B ONLY TO REFLECT THE FLOOR PLAN'S CONDITIONS. (((02/08/2015Changes to an approved set of plans. Note changes on delta 4a. PC only (((PLANCHECK FOR POWER AND ENERGY.   New 4-story, 338 unit apartment building.  10 TYPICAL UNITS. [[[FEES ARE BASED OFF APPLICANT, PLANCHECKER TO VERIFY FEES. FEES  FOR T24 (56,000SQFT), SMOKE DETECTORS (338), PANELBOARDS(SECTIONS) , AND OTHERS NOT INCLUDED DUE TO PRE CUT CHECK ]]]	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39779	12041-10000-04420	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019007	C2-1, CR-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM			PC Approved	04/02/2012 12:00:00 AM	ADDRESS	34.25776	-118.46707	T.I. to an existing retail space.  New receptacles, loads and lighting.  PLAN CHECK ONLY for Energy, with Emergency lighting.  No suite number, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39780	15041-10000-29302	3002 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.02706	-118.42817	PC FOR ENERGY. T.I FOR SEE'S CANDY STORE. CHANGE OF USE FROM PIZZA FAST FOOD. TAILOR METHOD. TOTAL AREA  3557 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39781	15041-10000-16882	6555 W BARTON AVE 2nd Floor	90038	4	144B185   969	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.08785	-118.33475	PC FOR POWER AND ENERGY. TI NO CHANGE OF USE,OFFICE. TOTAL AREA 32334 SAQ FT. (PHASE 1 ENTIRE FLOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39782	11041-10001-26154	2101 S SAWTELLE BLVD	90025	11	126B153   909	4260002029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	ADDRESS	34.03929	-118.44248	REVISION OF THE LIGHTING PLANS- ADDING A FEW UNIT EQUIPMENT AND DECREASED THE TOTAL LIGHTING WATTAGET.I. to an Existing restaurant.  Change of lighting.  PLAN CHECK ONLY for Energy. with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39783	16041-10000-22607	8479 N INDEPENDENCE AVE	91304	3	192B109   229	2779046013	R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.22436	-118.59083	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL TL INVERTER. (26) MODULES SPR-327NE-WHT-D AND (1) SMA SB-7000TL INVERTER. TOTAL SYSTEM SIZE IS 7KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39784	10041-10001-23382	428 W FLORENCE AVE	90003	8	102B201   908	6020029014	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	33.97439	-118.28149	Supplemental to Original: Moving Switchboard.New service to supply new carwash structure, and existing panel at gas station conveniance store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39785	16041-20000-08445	865 S FIGUEROA ST 15th Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for Title 24 only. Project site is a portion of the 15th floor of an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 1,595 sq. ft.Note: Building application has been generated under 16016-10000-05324	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39786	13041-10000-02008	1888 S SEPULVEDA BLVD	90025	5	126B153   131	4323021013	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	ADDRESS	34.04476	-118.44163	PC FOR NEW 600A SERVICE AND NEW 600A MAIN SWITCHBOARD. SUBPANELS ARE FOR FUTURE TENANTS. NOT PART OF PC. REMOVAL OF EXISTING POWER EQUIPMENT AND INSTALLAION OF NEW SWITCHBOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39787	13041-10001-25294	7328 N QUARTZ AVE	91306	3	186B117   764	2115009011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.20371	-118.56434	][][][EXPEDITE PER APPLICANT REQUEST][][][]PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 12.75KW DC ON NON-STANDARD CENTRIAL INVERTER PLAN IN A SINGLE-STORY HOME. XFORMERLESS SYSTEM. WILL BE UTILIZING LOAD CENTER. DOWNSIZING MAIN BREAKER FOR TIE-IN.  (61) TRINA #TSM-250(2)POWER-ONE - #PVI-6000-OUTD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39788	19041-10000-18299	601 S FIGUEROA ST 12TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Energy plan check for (2) restroom T.I located in the 12th floor of a high rise building. Scope includes new lighting and equipment with a total area of 522-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39789	16041-10000-07235	9321 N LOUISE AVE	91325	12	198B133   252	2766014005	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	05/28/2016 12:00:00 AM	ADDRESS	34.24002	-118.51146	PV1, rooftop solar installation 11.5kW system(43) SPR327NE-WHT-D(1) SPR-7700TL-US(1) SPR-3800TL-US(1) 125A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39790	13041-20002-26150	11455 N LAUREL CANYON BLVD	91340	7	213B149   511	2613027020	(T)(Q)C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM			PC Approved	04/07/2015 12:00:00 AM	ADDRESS	34.27805	-118.4529	[[[[4/7/15 CHANGES TO APPROVED SET OF PLANS. PLANCHECK ONLY; VERY MINOR CHANGES TO EXHAUST FANS. DELTA 10 CHANGES ONLY. ]]]]]New hamburger restaurant, with 1000 amp service.  Not in a Methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39791	15041-10000-03396	236 S LOS ANGELES ST Unit G	90012	14	129A213    65	5161024006	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.04922	-118.24386	First-time tenant restaurant space on ground story of 6-story mixed use apartment building.  Full plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39792	17041-20000-15973	15303 W VENTURA BLVD Ste 675	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	Existing commercial office remodel.  New lights, existing circuits.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39793	10041-20000-15803	7270 W MULHOLLAND DR	90068	4	156A181   677	5572001008	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1437.00, 1941.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	02/02/2011 12:00:00 AM	ADDRESS	34.11982	-118.35067	UPGRADE SERVICE FROM 200 A TO 600A SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39794	14041-10000-31712	901 S WINDSOR BLVD	90019	4	132B189   712	5090024012	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.05715	-118.32469	PV1.  Install 4.73 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39795	17041-20000-29624	5810 S NORMANDIE AVE	90044	9	108B197  1356	5002015001	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Issued	10/25/2017 12:00:00 AM	ADDRESS	33.98949	-118.30002	Plan check for power only. Project site is an existing commercial building (warehouse with tenant units). Project scope is a service upgrade to 2,500-amps and new transformers. Unit panels are existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39796	12041-20001-00010	9301 N TAMPA AVE Spc # 210	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM			PC Approved	02/14/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	"Modification to previously approved drawings.  Change to heating circuits, and reduction in the number of panels.  NO CHANGE TO LIGHTING.  Plan Check Only for ""DELTA 10"" Changes.        <<<<Existing restaurant space remodeled for new restaurant tenant.  New lighting and new ckts, no new panels.  Restaurant is located at the Northridge Fashion Center space # 210.  The modified load is less than 400 amperes based on the engineers calculation.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39797	14041-10000-28742	3131 S HOOVER ST Bldg # 4	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Closed	10/19/2017 12:00:00 AM	ADDRESS	34.02611	-118.28472	Full plan check for new 4-story undergraduate student housing over ground level multi-purpose classrooms, food court, dining hall, and supporting facilities.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39798	19041-10000-13615	800 W WILSHIRE BLVD STE 100	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.0493	-118.25841	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM (E) RESTAURANT TO OFFICE. TI FOR A BANK/OFFICE SPACE. TOTAL AFFECTED AREA IS 1656 SQ. FT. B19016-10000-10829	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39799	14041-20002-12032	12642 W SANDHILL LANE Unit #3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	33.97765	-118.41437	REVISIONS TO AN APPROVED SET OF PLANS.  REMOVAL OF SMS MONITORING SYSTEM.Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 3 of 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39800	13041-10001-25827	5927 W CARLTON WAY	90028	13	148-5A191 215	5545005900	OS-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM			PC Approved	04/09/2014 12:00:00 AM	ADDRESS	34.10057	-118.31889	CHANGES TO APPROVED: CLARIFIED 2 VERSIONS OF SAME LIGHT. Plan check only. PC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39801	18041-10001-27683	2131 W COLORADO BLVD	90041	14	162A223    98	5671010003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.13937	-118.21279	SUPPLEMENTAL FOR CHANGES TO APPROVED SET, DELTA 1 CHANGES INCLUDE REMOVAL OF SOME PROPOSED LIGHTS AND REPLACING WITH DOWN AND TRACK LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39802	16041-20000-17674	380 N CAROLWOOD DR	90077	5	141B157    10	4358006033	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.08562	-118.4289	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39803	16041-10000-18646	"300 W WORLD WAY NORT TERM. 3-""TMP74"""	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	TI to a newly renovated space inside Terminal 3 space# TMP74 of the LAX. Newly connected load < 400A. PC for T-24 only. Total area: 2,090 sq.ft.B# 16016-10000-11844	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39804	15041-20001-01610	15943 W GRESHAM ST	91343	12	195B141   406	2672024013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM			PC Approved	01/24/2015 12:00:00 AM	ADDRESS	34.23112	-118.47994	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 8.4kW (4.2+4.2). Ungrounded system.28  327W pv modules across 4 strings (2 per inverter).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39805	13041-20000-24195	7432 S KENTWOOD AVE	90045	11	102B165   359	4110021011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	33.97563	-118.40151	PV1 TRANSFORMERLESS SYSTEM. 17 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 4.25KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39806	15041-20000-39585	22741 W VICTORY BLVD	91307	12	180B097   546	2038038021	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	34.18663	-118.6225	TI, install new lighting fixtures in an (E) retail store. PC for Energy only. Total area: 34,121sq.ft . ((INTERIOR AND EXTERIOR REMODEL TO EXISGING RETAIL STORE, INCLUDING STOREFRONT REMODEL, REPALCE ROOF TOP EQUIPMENT AND STOREFRONT CANOPY))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39807	15041-10000-02565	1263 N BISHOPS ROAD	90012	1	136-5A215 604	5414019006	[Q]R3-1	Central	Central City North	Historic Cultural	YES	2060.10	Electrical	Electrical	Apartment			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.07034	-118.23474	Plan check for fire alarm. Install fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39808	13041-10001-27145	804 N EL CENTRO AVE	90038	13	141B189   100	5534031017	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			Reviewed by Supervisor	05/23/2017 12:00:00 AM	ADDRESS	34.08554	-118.32428	PC FOR CHANGES TO APPROVED SET OF PLANS. SERVICE DROPPED TO 600A AND REMOVED TRANSFORMER. UPDATED LIGHTING AND T24 AS WELL AS POWER CIRCUIT WIRING. ALL CHANGED CLOUDED DELTA 1. PERMIT WILL BE ISSUED FOR CHANGE OF CONTRACTOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39809	14041-20000-01983	866 S BRONSON AVE	90005	4	132B189   779	5092005026	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Closed	03/04/2016 12:00:00 AM	ADDRESS	34.05687	-118.3203	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan. using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39810	14041-20001-12189	8736 N OAKDALE AVE	91324	12	195B113   441	2782027008	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM			PC Approved	05/17/2014 12:00:00 AM	ADDRESS	34.22946	-118.56654	(((EXPEDITE FEES))))PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39811	16041-20000-22381	1200 S SANTA FE AVE 1ST FLOOR	90021	14	123A217   315	5166007011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Info Complete	07/13/2016 12:00:00 AM	ADDRESS	34.02944	-118.22979	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT FOR A NEW OFFICE SPACE.  1ST FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39812	18041-10001-46476	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.14436	-118.27496	"SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE CHANGING CONDUCTOR SIZING FROM 4"" TO 3"" - CONDUIT FILL <40%ORIGINAL PERMITPLAN CHECK FOR POWER ONLY FOR - BLOOM ENERGY FUEL CELL EQUIPMENT AND WIRING FOR CONNECTION TO EXISTING DISTRIBUTION SYSTEM."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39813	19041-10000-39920	1822 N NORTH BROADWAY	90031	1	138A219   111	5447025005	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.07183	-118.22158	TI IN AN EXISTING RESTAURANT. INSTALING NEW LIGHTS. T-24 ENERGY ONLY.BULDING PERMIT: 19016-10000-08935	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39814	16041-10000-32718	1118 S VICTORIA AVE	90019	10	129B189   216	5082026021	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	03/11/2017 12:00:00 AM	ADDRESS	34.05264	-118.32533	roof mounted pv PC FOR PV SYSTEM TOTAL OF 16 MODULES USING ac module system	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39815	14041-20000-19396	18000 W DEVONSHIRE ST	91330	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Expired	08/22/2016 12:00:00 AM	ADDRESS	34.25313	-118.52557	Plan check for energy only on office of 524 SQ feet in a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39816	17041-20000-27781	11668 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM			PC Info Complete	08/08/2017 12:00:00 AM	ADDRESS	34.20103	-118.38683	Plan check for hazardous location (Class 1, Div 2). Install new automatic manifold system in room SGENL H-004.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39817	16041-20000-21138	8950 N GLENOAKS BLVD	91352	6	195B173   149	2408005031	(Q)M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	34.2319	-118.36828	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 10,390 sq. ft.Note: Building application has been generated under 16014-20000-02717	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39818	12041-20000-16140	7800 N WOODLEY AVE	91406	6	189B141   290	2206009901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00, 1275.10	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.21161	-118.48344	Install new indoor lighting.  Plan check for energy only.Note: Outdoor light is under a separate plan check application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39819	15041-10000-05992	953 E 3RD ST 1ST FL	90012	14	129A217   161	5163006020	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	PIN	34.04633031	-118.23332713	OFFICE REMODEL OF AN EXISTING SPACE LOCATED ON THE 1ST FLOOR OF A 2-STORIES BLDGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT SUPPLIED FROM AN EM INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39820	18041-20001-17275	1325-1329 E PALMETTO ST	90013	14	126A217    34	5164003018	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	34.04045	-118.23165	09-06-2019 Changes to an approved set of plan, Changes include relocate service  and change from overhead to underground service, Methane Zone. All changes has been clouded as delta1,2 and 3 only. Plan check only. Permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39821	11041-10000-04490	2017 S OCEAN FRONT WALK	90291	11	106-5A145 509	4226013006	(Q)C1-1-O-CA	West Los Angeles	Venice	Venice		2735.00, 2739.00	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	11/18/2011 12:00:00 AM	ADDRESS	33.98441	-118.47142	T.I. FOR A  OFFICE, PREVIOUSLY RETAIL.  , NO PANELS, NO SERVICE CHANGE. Title 24. energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39822	19041-20000-14716	4753 N NOBLE AVE	91403	4	168B145   501	2264009021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.1572	-118.46194	PV1.  Install 10.56 kW DC / 8.976 kW AC roof mounted grid tied PV system.  (32) modules with 7.6 and 3.8 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39823	13041-10000-13396	888 S FIGUEROA ST #1750	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	ADDRESS	34.0465	-118.26225	inprovement in existing officesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39824	18041-20002-07141	5244 N LEGHORN AVE	91401	4	171B161   380	2345017082	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM			PC Approved	01/14/2019 12:00:00 AM	ADDRESS	34.16601	-118.41581	01-14-2018 Changes to an approved set of plan, Changes include 100A  AC disconnect to non fused. All Changes has been clouded. Plan check only. $0 permit fee per State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39825	13041-10000-35045	3105 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.02993	-118.37353	PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY OFFICE /MANUFACTURING  BUILDING . BUILDING PERMIT # 13010-10000-03264PLAN CHECK TIME EXTENSIONS 1 AND 2 HAVE BEEN FILED 5/23/2016	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39826	11041-10000-21218	1375 W ADAMS BLVD # A	90007	1	123B197   881	5055004026	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM	10/21/2011 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	34.03295	-118.29107	REMODEL OF COMMERCIAL  TO A RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39827	18041-10000-01540	1350 S SOTO ST	90023	14	121-5A221 212	5170019015	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Issued	03/30/2018 12:00:00 AM	ADDRESS	34.02519	-118.21956	INTERIOR LUMINAIRES COMPONENTS MODIFICATION IN PLACE AT A CHASE BANK. CIRCUITS AND CONTROLS  WILL REMAIN AS-IS.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39828	16041-20000-11343	15910 W VENTURA BLVD Suite 600	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Expired	05/02/2018 12:00:00 AM	ADDRESS	34.15561	-118.47969	Plan check for Title 24 only. Project site is a suite on the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 258 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39829	13041-20000-09797	1540 E ALCAZAR ST CHP Bldg	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.06338	-118.20434	Change to classroom 111, 112, 137, & 139 lighting and receptacles.  NOT a Place of Assembly per applicant (Subject to field verification.)  Load is 204 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39830	12041-10000-08165	15256 W TUPPER ST	91343	7	198B145   226	2656024007	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM			Reviewed by Supervisor	04/17/2012 12:00:00 AM	ADDRESS	34.23904	-118.46517	INSTALLATION OF A NEW 16.3KW ROOFTOP PHOTOVOLTAIC SYSTEM FOR AN EXISTING BUDDIST MONESTARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39831	15041-10000-39809	633 W 5TH ST 41ST FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EM CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39832	17041-20001-40201	6535 N ODESSA AVE	91406	6	180B137   401	2231004060	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM			PC Approved	12/14/2017 12:00:00 AM	ADDRESS	34.18962	-118.49041	Expedite per applicant request.Plan check for solar pv system, roof-mounted array on SFD.Derating main breaker to 175A.10.4kW ungrounded system. (2) 5.2kW inverters.(29) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39833	14041-20000-23465	19835 W DINA PL	91311	12	204B113    99	2708026017	RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.2582	-118.56507	PV1 SFD. TOTAL SYSTEM SIZE 7.6 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING THE STANDARD PLAN. TOTAL OF 39 MODULES. SYSTEM USING POWER OPTIMIZERSFIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39834	18041-10001-36208	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.05855	-118.23671	INSTALLING 6 SETS OF 9 BUSSWAYS (TOTAL OF 54) RATED AT 600AMPS EACH FOR FUTURE POWER DISTRIBUTION UNITS (PDU's)NO NEW LOAD ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39835	19041-10000-23720	924 S CATALINA ST	90006	10	132B197   973	5094024015	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			06/20/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	08/02/2022 12:00:00 AM	ADDRESS	34.05498	-118.29523	FULL PLAN CHECK FOR A NEW 6-STORY 30-UNIT APARTMENT COMPLEX. SCOPE INCLUDES NEW 1200A SERVICE. TOTAL AFFECTED AREA IS 25692 SQ.FTB#18010-10000-01046	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39836	18041-20001-43283	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			PC Approved	05/23/2019 12:00:00 AM	ADDRESS	34.04166	-118.26677	5/23/2019changes to an approved set of plans.  changes to provide EM circuit to EM light fixtures within high rise building.  this is plan check only.  ((((ti to a first time tenant.  plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39837	16041-10000-03985	12511 W VENICE BLVD	90066	11	111B153   213	4246026007	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM			PC Info Complete	02/04/2016 12:00:00 AM	ADDRESS	34.00326	-118.43497	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (COFFEE SHOP). SCOPE INCLUDE NEW LIGHTS, RECEPTACLES, AND A NEW 200A PANEL. TOTAL AFFECTED AREA IS 1082 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39838	09041-10004-17090	5557 E VALLEY BLVD BUILDING-330	90032	14	139-5A237  59	5220032003	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Finaled	01/23/2012 12:00:00 AM	ADDRESS	34.07723	-118.16241	CHANGES TO THE APPROVED PLANS. ADD AND MODIFY EXISTING LOADS. SHOW ALL THE LOADS ON THE PLAN PER INSPECTOR'S REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39839	14041-20001-24768	5650 W MANCHESTER AVE	90045	11	096B169   549	4125018014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			PC Approved	10/23/2014 12:00:00 AM	ADDRESS	33.95972	-118.37999	[[[[[10/23/2014 Changes to approves set of plans. Delta 1 changes only. Adding outlets and relocating switches. ]]]]]]NEW PIZZA RESTAURANT. EXISTING SERVICE & PANELS. PLAN CHECK FOR NEW CIRCUITS & T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39840	16041-20000-08959	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Expired	04/13/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLANCHECK FOR OUTDOOR LIGHTING FOR SOLAR CANOPIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39841	13041-20000-16109	7020 N MIDDLESBURY RIDGE CIR	91307	3	183B089   258	2028045012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.19892	-118.64538	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 5184 KW. 24 MODULES AND 1 LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39842	12041-10000-16630	4857 N FULTON AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	11/08/2012 12:00:00 AM	ADDRESS	34.15913	-118.42262	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN. BUILDING #1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39843	18041-10000-24716	1925 W OLYMPIC BLVD	90006	1	130-5A203 221	5136008025	C4-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.05119	-118.27827	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39844	16041-20001-20447	326-338 S RENO ST	90057	1	136-5A201 249	5155009013	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Apartment			04/26/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.06744	-118.28363	Revisions to approved set of plans.  Revision of elevator HP, supply wiring detail, and location.  Approval for delta-C revisions only. (((New 5-story, 65-unit apartment building.  1600A 208Y/120V service.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39845	15041-20001-27844	3316 S MAIN ST	90011	9	118-5A205 187	5120003009	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	PIN	34.01887477	-118.27203514	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 40 kWac and consists of (4) inverters, (148) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39846	15041-10000-29349	5007 S NORMANDIE AVE	90062	8	111B193  1127	5016031021	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	PIN	33.99797898	-118.30049626	PV1 roof-mounted 3.kW system  for a single family dwelling. Scope of work : (11) Kyocera KU2656ZPA modules, and (1)ABB-PVI-3.0 inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39847	15041-10000-24180	5858 S MADDEN AVE	90043	8	105B189   154	4005013017	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.9874	-118.32533	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(19) KYOCERA KU2656 MODULES(1) ABB PVI-5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39848	17041-10001-33094	4020 S LINCOLN BLVD C	90292	11	108B149  1249	4230002013	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	33.99001	-118.44704	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE LOCATION OF TIME CLOCK ,  AND REARRANGEMENT OF NEW LIGHTING ALL CHANGES HAVE BEEN CLOUDED UNDER DELTA 1. RESTAURANT TI. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39849	19041-10000-37542	1125 N GRACE LANE	90049	11	141B141   238	4429005020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	07/28/2022 12:00:00 AM	ADDRESS	34.08078	-118.48052	Power plan check for a complete service upgrade for a residential unit with an additional of 2000-SQ FT. Scope includes (1) 600-Amp service, (5) subpanels, and other associated equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39850	18041-10000-10534	854 N KODAK DR	90026	13	142-5A203 302	5427021022	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.08428	-118.27987	NEW ROOFTOP SOLAR SYSTEM IN A SINGLE FAMILY DWELLING. SYSTEM CONSIST OF 18 AC MODULES (SUNPOWER X22-360). SCOPE INCLUDES NEW 100A LOAD CENTER AND SUNPOWER SOLAR MONITOR. SYSTEM SIZE IS 6.48KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39851	10041-10000-07672	3620 S MCCLINTOCK AVE 8th Floor	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.0213	-118.28935	Ti work for second floor of mudd bldg, power energy, lighthing and title 24. existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39852	14041-20000-31035	23335 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Issued	01/13/2015 12:00:00 AM	ADDRESS	34.1573	-118.63409	plan check for title 24 outdoor lighting for an existing parking lot.  hardscape area 346,139 sqftNote: Permit is under a separate application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39853	16041-20000-32344	3030 W 8TH ST	90005	10	132B197   465	5094012029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM			Reviewed by Supervisor	09/29/2016 12:00:00 AM	ADDRESS	34.0576	-118.29246	PV2.  Install 36.6 kW DC carport mounted solar system.  (120) modules with (2) 17.5 kW AC rated transformerless inverters. (2) systems are being submitted for the same address - same system size/details but interconnecting to different switchgears with separate meters.  System 2 of 2 - designated 'System B' on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39854	15041-20001-22450	6115 W SUNSET BLVD SUITE 100	90028	13	147A189    24	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.09819	-118.32261	02/17/2016 Changes to an approved set of plans. Circuits have been added for lighting and power for light fixtures and (2) sump pumps in a newly created storage room in the basement. All changes have been clouded and marked as Delta 4.*****Previous Work Description*****Plan check for power and Title-24 (energy).  Total area = 5,273 sq. ft. (indoor) + 600 sq. ft. (outdoor).  T.I. to existing restaraunt space.  Complete electrical retrofit with new 600 A distribution board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39855	12041-10000-14586	28166 S WESTERN AVE	90732	15	024B193   622	7442030207	P-1XL, [Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM			PC Approved	08/31/2012 12:00:00 AM	ADDRESS	33.76318	-118.31057	TI to an existing Starbucks. Plan check for energy and emergency lighting. 1000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39856	15041-20000-06429	5700 W WILSHIRE BLVD Suite 250	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM			PC Approved	03/04/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	Title 24 plan check only.  Total area = 5,698 sq. ft.T.I. to existing commercial broadcasting center.  New lights and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39857	17041-20000-38540	8870 N TAMPA AVE	91324	12	195B117    63	2783025083	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Issued	11/15/2017 12:00:00 AM	ADDRESS	34.23179	-118.55382	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for solar pv system w/roof-mounted array on commercial building.Total system size: 33.3kW ungrounded.(1) 33.3kW SolarEdge inverter.(120) 360W pv modules.(60) 800W power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39858	13041-20001-26607	2035 N HIGHLAND AVE	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	ADDRESS	34.10759	-118.3376	(((EXPEDITE FEES)))PV2 COMMERCIAL BUILDING. PV SYSTEM. TOTAL SYSTEM SIZE 7.7KW AC USING ENPHASE MICROINVERTERS. NONSTANDARD PLAN.  15 KVA TRANSFORMER IS PART OF PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39859	13041-10000-23150	5957 W BARTON AVE UNIT 1-UNIT 16	90038	13	144B189   910	5534025024	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Apartment			08/26/2013 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.08813	-118.32419	COMPLETE REWIRING OF 16 UNIT APARTMENT IN A TWO-STORY BUILDING. FEES FOR METER SECTIONS HAS NOT YET BEEN CHARGED DUE TO ELEVATION DIAGRAM MISSING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39860	16041-20000-08635	700 S FLOWER ST 7th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,574 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39861	19041-10001-02726	863 S WELLESLEY AVE	90049	11	129B141   620	4264016026	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM			PC Approved	02/07/2019 12:00:00 AM	ADDRESS	34.04589	-118.4754	SUPPLEMENTAL  CHANGES IN APPROVED SET CHANGES INCLUDE CHANGE OF LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39862	15041-10000-34597	2412 N EADS ST	90031	13	144B213    54	5445002031	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Apartment			10/16/2015 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	04/09/2024 12:00:00 AM	ADDRESS	34.09459	-118.24012	Full PC for a new 8 unit apartment building. New 800 A service. Unit panel confuguration is typical for all units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39863	13041-20000-08445	8401 N VAN NUYS BLVD #36/#38	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	ADDRESS	34.22308	-118.44896	Combining two existing retail spaces into one retail space.  Load is 160.9 amps per plans.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39864	18041-10000-19960	11881 W LINDBLADE ST	90230	11	108B161    78	4218004018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM			Reviewed by Supervisor	06/04/2018 12:00:00 AM	ADDRESS	33.99563	-118.41468	PC FOR INSTALLAION OF NEW ESS SYSTEM  (WITH EXISTING ROOF MOUNTED PV).SCOPE INCLUEDS 2 POWERWALLS.SEPERATE PEMIT FOR LOAD CENTER UNDER 17041-90000-12520	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39865	14041-20000-34491	7809 N SIMPSON AVE	91605	6	189B169   713	2310025023	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.21232	-118.389	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(18) ENPHASE M-215 MICROINVERTERS(18) HYUNDAI HEAVY INDUSTRIES M250 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39866	18041-20001-18954	7230 N VARNA AVE	91605	2	183B157    26	2328028030	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.202	-118.42457	11-21-2018 Changes to an approved set of plan, changes include update panel A and B to new. All changes has been clouded as delta 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39867	14041-20000-13339	4645 N WESTCHESTER DR	91364	3	168A111    82	2174012004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.15468	-118.58327	9.5kw PV1 roof-mounted system with (2) transformerless  Solaredge # SE3800A-US inverter, Solaredge  power optimizer P300, and (36) Trina Solar #TSM-250PA05.18 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39868	13041-10000-04948	1888 S SEPULVEDA BLVD	90025	5	126B153   131	4323021013	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.04476	-118.44163	T24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER. PLAN CHECK FOR TITLE 24 (INDOOR LIGHTING USING TAILORED METHOD AND OUTDOOR LIGHTING) AND EMERGENCY LIGHTING ON EXISTING TENANT SPACE. PREVIOUS TENANT WAS PRINT SHOP NEW TENANT IS RETAIL AND WAREHOUSE. CONNECTED LOAD IS LESS THAN 400A, NO UNDERGROUND WORK (METHAN BUFFER ZONE).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39869	18041-20000-16267	625 N HANLEY AVE	90049	11	138B137   604	4494019033	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.0706	-118.48746	Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (36) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39870	17041-10001-00848	8060 W JOVENITA CANYON ROAD	90046	4	153B173   794	5565018002	RE11-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.11342	-118.37315	02/07/2017 Changes to an approved set of plan. Changes include revised modules layout and revised subpanel. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39871	11041-20000-21318	1840 S CENTURY PARK EAST 10TH-12TH-& 19TH FL	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.06188	-118.41473	PLAN CHECK POWER AND ENERGY FOR 10TH, 11TH, 12TH AND 19TH  FLOORS. OFFICE TIRequest for Modification to separate Fire Alarm system filed 11.09.11	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39872	19041-10000-42473	16833 W NORDHOFF ST	91343	12	198B133   613	2687005006	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.2359	-118.49929	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 28.08 kW DC/24.96KVA PV1 SYSTEN CONSISTING OF 78AC MODULES(SUNPOWER X22-360-D-AC) CONNECTED TO NEW 400A SERVICE $0 FEE PER STATE SENATE BILL SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39873	17041-20001-22559	3758 S HARVARD BLVD	90018	8	117B193   457	5041033008	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			Reviewed by Supervisor	07/12/2017 12:00:00 AM	ADDRESS	34.01884	-118.30604	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.51 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39874	18041-20000-47330	1463 N FLORESTA PL pv1	90272	11	135B121    55	4420031017	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.0625	-118.5477	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39875	17041-10001-01177	725 E 104TH ST	90002	8	090A207    56	6051004016	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	33.94201	-118.26217	PC for Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling. ***Permit under an onlined pulled permit due to changes to plane (Removing a module).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39876	14041-20000-32544	925 W 34TH ST #B20,#263-E. Lobby	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	PIN	34.02383917	-118.28572873	T.I. to existing medical building in dental office (Rooms B20, East Lobby, and 263).  Install branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39877	16041-20001-03447	9871 N SAN FERNANDO ROAD	91331	7	201B165    79	2624020028	M1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	ADDRESS	34.24947	-118.40499	Revisions to approved plans.  Change to DWP fault current and equipment AIC ratings.  (((Plan check for power and energy.  1 story masonry block building 23279 sf  (8) units S-1 occupancy, (4) units F-1 occupancy)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39878	15041-20000-11992	9731 N VALJEAN AVE	91343	12	201B137   505	2677019067	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.2474	-118.48729	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (2) combiner boxes, and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39879	17041-30000-23224	941 N HIGHLAND AVE	90038	4	144B185  1015	5532012041	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.08829	-118.33879	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 360 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39880	12041-10000-12258	11766 W WILSHIRE BLVD # 520&550	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM			PC Approved	05/29/2012 12:00:00 AM	ADDRESS	34.04804	-118.46227	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR #520 AND #550 OFFICE RENOVATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39881	10041-10000-23185	5230 N LANKERSHIM BLVD	91601	4	171B173  1387	2350018086		North Valley				1253.20	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.16571	-118.37485	INSTALL A NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39882	19041-10000-04451	4800 S ALLA ROAD	90066	11	105B157   536	4223008005	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM			Corrections Issued	02/06/2019 12:00:00 AM	ADDRESS	33.98292	-118.42948	PC FOR NEW FA SYSTEM IN A NEW 2-STORY OFFICE BUILDING (OFFICE BUILDING 2). SCOPE INCLUDES FA PANEL, ANNUNCIATOR, CELL COMMUNICATOR AND 42 DEVICES. DUCT SMOKE DETECTORS, TAMPER SWITCH, FLOW SWITCH AM SMOKE FIRE DAMPERS ARE CONTRACTED BY OTHERS AND NOT PART OF THIS BATTERY CALCULATIONS. *Plan check only is set beacause permit was finaled under application number 19041-10000-13129	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39883	16041-10001-45768	3980 W WILSHIRE BLVD	90010	10	132B189    79	5092030035	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	11/25/2020 12:00:00 AM		Permit Finaled	12/03/2020 12:00:00 AM	ADDRESS	34.06153	-118.31391	Change to an approved set by adding a new fire pump and a jocky pump on the plan. Scope includes new load calculation, voltage drop and fault current calculation. All changes under delta-12 only.(((Plan check for power and energy. New 7-story mixed-use building with approximately 15,346 sq. ft. ground retail and 228 residential units above. Ground level and 3 subterranean levels of parking. 5000A service. Fire alarm variance is on file.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39884	11041-10000-11468	451 S HEWITT ST	90013	9	127-5A215 370	5163022019	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	ADDRESS	34.0421	-118.23525	CHANGE OF USE FROM AN OFFICE BUILDING TO A COFFEE ROASTING PLANT.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39885	17041-10002-12711	1060 S BROADWAY	90015	14	126A209   131	5139014011	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.0397	-118.25861	revision of an approved set for a fire alarm system for a 10-story hotel. change include revision of power boosters and ground floor coverage revisions.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39886	15041-30000-37860	5919 S VAN NESS AVE	90043	8	105B189   261	4005027019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	PIN	33.98672606	-118.31795894	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 4.2 kWac.  Single inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39887	18041-20000-33423	20657 W CHESTNUT CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Issued	08/31/2018 12:00:00 AM	ADDRESS	34.2938	-118.58454	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39888	17041-10000-12991	1123-1137 S MAIN ST	90015	14	126A209   219	5139017027	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			PC Info Complete	06/07/2017 12:00:00 AM	ADDRESS	34.03868	-118.25875	NEW PARKING LOT. PC FOR T24 ENERGY ONLY FOR NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39889	11041-20000-26413	17947 W CHATSWORTH ST Bldg. L	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	05/23/2012 12:00:00 AM	ADDRESS	34.265	-118.52509	Provide 1600 A new service with 5 service disconnecting means, for a remodel of an existing commercial building.  The remodel is for exterior building lighting, and interior spaces L1 and L4.  Spaces L2 and L3 will be part of future work to be done by the tenants.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39890	18041-10000-13073	14753 W AETNA ST	91411	6	177A149    72	2241025006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.18022	-118.45479	"T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES DUE TO FIRE DAMAGE. TOTAL AFFECTED AREA IS B#17016-30000-29501""COMPLY WITH DEPARTMENT ORDER effective date 06/23/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39891	12041-10000-19438	21505 W RINALDI ST Bldg 1A	91311	12	210B105   275	2723004020	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM			Verifications in Progress	12/19/2012 12:00:00 AM	ADDRESS	34.27132	-118.59951	PLAN CHECK POWER AND ENERGY. NEW SINGLE STORY ADMINISTRATION BLDG (BLD 1A) FOR CHARTER SCHOOL. (APPLICATION 1 OF 6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39892	11041-10000-25912	3023 S WESTERN AVE 1-60	90018	10	120B193   522	5053006903	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Apartment			12/12/2011 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	34.02667	-118.30906	CONSTRUCT NEW 4-STORY, 60-UNIT, TYPE VA, AFFORDABLE HOUSING BLDG W/ FIRST LEVEL FOR PKG AND RESIDENTIAL/COMMON AREA. NFPA-13 automatic fire sprinkler sytem for story and allowable floor area increase. Variance is filed to separate the FA PLANS.Note that Title compliance forms and single line diagram for the meter sections are missing from the plans	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39893	14041-10000-02414	1270 S LOS ANGELES ST	90015	14	124-5A209 126	5145028010	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.03582	-118.25895	Remove HID light fixtures and replace with new fluorescent fixtures in a retail space.  Title 24 plan check for fixture one-for-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39894	13041-10000-23698	9301 N TAMPA AVE SPACE# 171	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	TITLE-24 ONLY PC. CHANGE OF USE FROM  RETAIL TO TAKE-OUT RESTAURANT.  TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39895	18041-20000-31003	4563 E CLELAND AVE	90065	1	151-5A221  73	5475018002	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.11075	-118.21865	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39896	15041-20000-01906	10831 W CROCKETT ST	91352	2	192B177   712	2407024029	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Expired	02/15/2017 12:00:00 AM	ADDRESS	34.22038	-118.36623	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39897	11041-20000-05495	5901 N DE SOTO AVE	91367	3	177B109   204	2149002028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM	06/07/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.17807	-118.5905	Plan check for power and energy for vocational school (California Lutheran University).  Existing building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39898	18041-10001-48144	2430 E PORTER ST	90021	14	121-5A217 295	5168029024	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.02651	-118.22916	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY. ADDING 16 ADDITIONAL FIRE ALARM DEVICES DUCT DETECTORS AND 1 CONTROL RELAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39899	16041-20000-24976	18232 W LUDLOW ST	91326	12	210B125   489	2715017030	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.27076	-118.53088	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 5kW ungrounded system.(26) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39900	17041-20000-22145	16045 W SHERMAN WAY K	91406	6	183B141    78	2206035032	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.2014	-118.48283	ti to an existing commercial building. all lights existing per applicant.  plan check for energy requested by applicant.  total square footage 500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39901	18041-10000-33418	5401 S BEETHOVEN ST	90066	11	102B157    49	4211009007	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	33.97765	-118.42217	NEW ROOF MOUNTED 150KW (AC) / 224KW (DC) PV SYSYEM WITH 584 PV MODULES.NO FEES PER SENATE BILL: AB-1414/SB-1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39902	12041-10000-15925	555 S FLOWER ST 34th Floor	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for energy and emergency lighting. Commercial high rise. 257 sqft. 34th Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39903	14041-10001-17505	3900 N STANSBURY AVE	91423	4	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.14084	-118.44264	PC FOR CHANGES TO APPROVED SET OF PLANS. REVISED SINGLE LINE BASED ON FIELD INSTAL. PROVIDED UPDATED SHORT CIRCUIT RATINGS. PLAN CHECK DELTA  9	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39904	18041-10002-26777	653 E MILWOOD AVE	90291	11	108B145   951	4241005024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM			Re-Activate Permit	12/28/2018 12:00:00 AM	ADDRESS	33.99215	-118.46385	Clanges to approved set of plans - changes include relocation on 5.2kva inverter, and removal of AC disconnect. see site plan and single line for updated changes under delta G	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39905	14041-10000-25232	2049 S CENTURY PARK EAST suit # 310	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	title 24 and emergency lighting, for 3rd floor of a high rise,  suit 320	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39906	11041-10000-08375	6112 N LINDLEY AVE BLDG 2	91335	12	177B125   657	2123024025	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	09/12/2011 12:00:00 AM	ADDRESS	34.18096	-118.52711	NEW FIRE ALARM FOR CHILD'S WORLD SCHOOL BUILDING #2.  3 SEPARATE BUILDINGS USING ONE CONTROL PANEL.  BUILDING #1 (6120 LINDLEY), BUILDING #5, AND BUILDING #2 (61121 LINDLEY).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39907	14041-10000-02384	10326 N SHERMAN GROVE AVE	91040	7	204B189   449	2560018019	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Apartment			01/28/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.25687	-118.32002	PV1, Install 11 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel. (2)Transformerless inverters: SOLAREDGE SE6000A-US-ZB-U & SOLAREDGED SE5000A-US(44) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39908	17041-10000-40417	10201 W PICO BLVD EV-2	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	16 ea new EV charging stations on the lower and P1 levels of the existing Galaxy parking structureFULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39909	15041-20000-04084	4625 N LANKERSHIM BLVD	91602	2	168B173  1094	2421027009	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM			PC Info Complete	07/21/2015 12:00:00 AM	ADDRESS	34.15471	-118.36871	NEW CONSTRUCTION. NEW AUTO DEALERSHIP WITH BODYSHOP AND VEHICLE SERVICING.FULL BUILDOUT. NEW ELECTRICAL SERVICE, EQUIPMENT AND LOADS. PC FOR POWER AND ENERGY. CONTAINS SERVICE, SALES AND OUTDOOR AREAS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39910	18041-20000-05455	13318 W WINGO ST	91331	6	198B157   171	2625002008	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.24214	-118.42337	PV1.  Installing 12.025 kW DC roof mounted grid tied PV system.  (1) 10kW rated central inverter with (37) 325W PV modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39911	17041-10000-22303	1315 W FLORENCE AVE	90044	8	102B197  1157	6014033032	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Apartment			07/03/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	33.97475	-118.29859	FULL PLAN CHECK FOR NEW 3 STORY  20 UNIT LOW INCOME APARTMENT, 1000A 120/240V SERVICE. 12,860 SQ.FT INDOOR + 2554 SQ. FT OUTDOOR.  B# 16010-10000-06259	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39912	18041-10000-48450	7006 W LANEWOOD AVE 1-18	90028	13	147B181   508	5548013011	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			12/21/2018 12:00:00 AM			Reviewed by Supervisor	01/02/2019 12:00:00 AM	ADDRESS	34.09908	-118.34165	TI FOR AN EXISTING 18 APARTMENT BUILDING. SCOPE INCLUDES NEW 800A SERVICE, NEW PANELS, EQUIPMENT, LIGHTING AND RECEPTACLES. ALL EXISTING CIRCUITS FOR COMMON AREAS TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39913	13041-10000-23686	8126 N WHEATLAND AVE	91352	2	189B177    54	2407008002	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling	1	Dwelling - Single Family	08/29/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.2181	-118.36165	PV1.  Install 4.16 kW DC roof-mounted solar array, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39914	19041-20000-48119	2394 N BROOKSHIRE LANE	90077	5	153B141   196	4377047020	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.11356	-118.47721	PV1 PLAN CHECK FOR NEW PV SYSTEM AND ESS. PV SYSTEM SIZE IS 10.08 KW DC/7.6 KW AC. ESS SIZE IS 13.5 KWH. SCOPE OF WORK CONSISTS OF (32) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER, (2) PANELS, AND A 5KW BATTERY	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39915	19041-10000-15883	736 N BROADWAY UNIT 105	90012	1	133-5A215  61	5408024011	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	PIN	34.06131145	-118.2384062	PC ENERGY ONLY FOR CHANGE OF USE (E) RETAIL TO (N) RESTAURANT. SCOPE ARE IS 629SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39916	18041-20001-24016	17028 W DEVONSHIRE ST	91325	12	204B133   214	2694001031	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM			PC Approved	07/05/2018 12:00:00 AM	ADDRESS	34.25731	-118.50316	7/5/2018changes to an approved set of plans.  changes to include reconfigure existing circuits to existing light fixtures and controls.This is plan check only.(((Plan check for Title 24  energy only in existing space T.I. hair salon. Total area: 1313 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39917	16041-10005-39052	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	02/23/2024 12:00:00 AM	ADDRESS	34.16603	-118.52861	"Changes to an approved set of plans. All changes are clouded under delta 4 & 6. Changes include relocating title 24 controls on lighting floor plans, relocating water heater/circulation pump, adding a sterilization equipment to panel ""4HA"", and revising load calculations."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39918	14041-20001-03630	17631 W VANOWEN ST	91406	6	183B129  1030	2229001017	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.19401	-118.51769	plan check for additional 12 devices on extended area	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39919	14041-10000-35594	2020 E 7TH PL	90021	14	124-5A217 336	5166014012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.03342	-118.23137	Title 24 plan check only.  Total area = 16,586 sq. ft.Remove HID lighting and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39920	16041-10000-04906	966 N MORAGA DR	90049	5	141B145   234	4368019015	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.08188	-118.46728	Permit fees are $0 due to senate bill 1222.((((PV1, rooftop solar installation 14kW system. Interconnect with 600A MS.(48) SPR-327NE-WHT-D(2) SMA 7000US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39921	16041-10000-41126	2119 S OAK ST	90007	1	124-5A203 287	5124013020	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.03415	-118.27967	LOW RISE RESIDENTIAL LIGHTING UPGRADES. PC FOR T24. NO DENSITY CALC REQUIRED. PC CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39922	12041-10001-27702	409 S BURLINGTON AVE	90057	1	133-5A205 194	5154023014	R4-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.06028	-118.26974	CHANGES TO APPROVED: ELECTRIC TO GAS RANGE FOR UNITS; STORAGE ROOM TO OFFICE AND  REMOVE UPLIGHTING.  Plan Check only.PLAN CHECK FOR POWER AND ENERGY. NEW 30 UNIT 4STORY AFFORDABLE APARTMENT with 1600A SERVICE. BELOW GRADE PKG. METHANE.9 TYPICAL UNIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39923	10041-20000-15723	15853 W MONTE ST	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.31022	-118.47637	Plan check for installation of 11.7KW Photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39924	12041-20001-24647	3409 S OVERLAND AVE	90034	5	120B161   590	4254025039	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.02566	-118.41255	Changes to general lighting. Emergency lighting has not been affected from the previously approved set of plans.Plan check for energy and emergency lighting. 1889sqft. Coffee shop. Single story stand alone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39925	11041-10000-12477	105 N ROBERTSON BLVD	90048	5	138B169   353	4334001012	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			Verifications in Progress	07/15/2011 12:00:00 AM	ADDRESS	34.07547	-118.38389	T.I.  Removing existing feeder and extending it to newly relocated house panel that feeds other 2 panels and adding additional circuits.  Also, for the inside, there is a remodel of light fixtures that is to be done.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39926	19041-20000-19840	6213 E BURWOOD AVE	90042	14	157-5A231  32	5483022019	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/29/2019 12:00:00 AM	ADDRESS	34.12757	-118.18416	Install 13.5 kWh energy storage system.  125A load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39927	12041-20000-14153	3109 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.03003	-118.37367	T24 lighting plan check for create toilet room from existing warehouse space.The electrical permit is to install new circuits for remodeled bathroom, and instahots for restroom and breakroom area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39928	19041-20000-03517	7801 N HAYVENHURST AVE	91406	6	189B137   125	2205009094	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.21242	-118.49404	Tenant improvement to (E) commercial office.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39929	19041-20000-39980	1500 S CENTRAL AVE UNIT D	90021	14	121-5A211 291	5130014025	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM			PC Info Complete	10/03/2019 12:00:00 AM	ADDRESS	34.02704	-118.24799	TENANT IMPROVEMENT OF RETAIL STORE TITLE-24 P.C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39930	19041-30000-05482	1627 N BLUE JAY WAY	90069	4	147B169    77	5561026014	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	ADDRESS	34.10247	-118.38683	Plan check for power only. Project site is a new 2-story single-family dwelling. Work includes an 800 amp service, a back-up generator, distribution equipment, and loads.Note: Building applications have been generated under 13010-10000-04086/13010-10002-04086. Electrical permit fees have been paid under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39931	15041-20001-23689	2829 W HYANS ST 1-12	90026	13	138A203   152	5156016017	R3-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			07/13/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	34.07331	-118.27888	07/13/2016 Changes to an approved set of plans. Service type has gone from overhead to underground. Project is located in a methane zone and required service equipment changes have been made.*****Previous Work Description*****Plan check for power and Title-24 (energy).  Total area = 19,564 sq. ft. (indoor) + 1,000 sq. ft. (outdoor)  New 12 unit apartment building with 1 garage levels and three apartment levels.  New 800 A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39932	16041-10000-01228	1676 E 108TH ST	90059	15	088-5A213  73	6069002006	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Expired	02/12/2018 12:00:00 AM	ADDRESS	33.93769	-118.24341	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(22) SILEVO 290 MODULES(1) ABB 6000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39933	15041-20000-22248	21650 W OXNARD ST Suite 1910-1920	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	TI to existing high rise office commercial building (19th floor). Plan check for energy only. Adding new lighting including emergency. Total sqft. 3,072	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39934	18041-10000-02540	123 S LA BREA AVE	90036	5	138B181   965	5513019041	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/29/2018 12:00:00 AM		Issued	01/29/2018 12:00:00 AM	ADDRESS	34.07284	-118.34424	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR RETAIL STORE. TOTAL AFFECTED AREA IS 3504 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39935	16041-20000-02627	8926 W RIDERWOOD DR	91040	7	207B189   373	2547028023	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.26541	-118.32644	Plan check for PV roof mounted system. System size: 7.5kW with 30 modules and 30 microinverters. Home owner builder submitting the plan	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39936	19041-10000-07926	7600 W BEVERLY BLVD	90036	4	138B177   451	5512004908	OS-1XL-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.07489	-118.3549	Plan check for a fire alarm system located in a commerical building with (1) fire alarm panel, and (105) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39937	19041-10000-53838	13210 S ESTRELLA AVE	90248	15	078B201    33	6132003013	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.91195	-118.28596	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39938	14041-20000-13325	865 S FIGUEROA ST SUITE 2400	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. NO CHANGE IN OCCUPANCY. OFFICES. HIGHRISE. NEWLY CONNECTED LOAD < 400AMPS. 4406 SQFT, EMERGENCY LIGHTING. SUITE 2400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39939	15041-10000-27320	2028 S BENTLEY AVE	90025	5	126B153   412	4323023033	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.04285	-118.43873	PC for new fire alarm system installed at a 7 unit 4-story apartment bldg. (1) FA panel. (49) fire alarm devices, (1) communication panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39940	17041-10000-08637	15840 W VENTURA BLVD	91436	5	168B141   638	2283009012	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.15548	-118.47886	PC for energy only, outdoor. Removing HID fixutres and replacing them with New LED ones. Area: 23,050	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39941	19041-10000-07793	14635 W VENTURA BLVD	91403	4	166-5A151  67	2265005003	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.15166	-118.45209	T-24 PLAN CHECK FOR A T.I. IN A RETAIL SPACE. ( NO CHANGE OF USE). SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 1505 SQ.FT SOME FEES ARE PAID UNDER THE EXPRESS PERMIT # 19041-10000-07462	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39942	18041-10001-20929	20747 W DEARBORN ST	91311	12	198B109   144	2748036022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Approved	07/30/2018 12:00:00 AM	ADDRESS	34.23734	-118.58591	EXPEDITED PER APPLICANTS REQUEST. PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 67.89 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39943	19041-10000-12543	11356 W KINGSLAND ST	90066	11	117B157   154	4249004026	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Expired	09/15/2023 12:00:00 AM	ADDRESS	34.01976	-118.4289	(ePlan) PV1. Install roof mounted Solar System that consist of 1 Inverter & 33 modules @10.725KWdc and 10KWac & 2 ESS System @27KWH.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39944	15041-10000-32560	9055 N WOODMAN AVE	91402	6	195B153   129	2639033003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	PIN	34.23397777	-118.4403076	ALTERATIONS IN AN OFFICE BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39945	16041-20001-41865	7556 N HESPERIA AVE	91335	3	186B125   213	2120021003	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM			PC Approved	12/27/2016 12:00:00 AM	ADDRESS	34.2081	-118.5261	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 12.6 kWac and consists of (45) modules, (45) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39946	14041-20001-07808	7307 N FIGUEROA ST STE 202	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	34.13662	-118.18837	Change from previously approved plans.  Change include additional lights.  Plan check for energy only.Note: Permit is under a separate application.*****Previous Description*****T. I. FOR (E) 1,959 SF RESTAURANT. PC FOR T24 ENERGY ONLY. NEW LIGHTING. LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39947	17041-30000-33497	2029 S CENTURY PARK EAST 8th Floor-RR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing highrise men and women restroom 8th Floor. Total area: 410 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39948	15041-10000-12556	8413 W BLACKBURN AVE 1-25	90048	5	138B173   895	5511032061	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			04/27/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.07224	-118.37373	Power and energy plan check for a new 25-units, 4-story apartments; service is 1200-Amp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39949	18041-10000-38755	12930 W VENTURA BLVD	91604	2	165B161  1027	2385026024	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.14513	-118.41481	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39950	13041-10000-14134	3328 N SCADLOCK LANE	91403	4	159B145   472	2279028012	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.13145	-118.46811	PV1.  Install roof-mounted solar array (11.25kW DC system size), interconnect into existing main service panel.  {45 modules: Canadian Solar CS6P-250P} {Microinverters: Enphase M215-60-2LL-S2}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39951	16041-10000-32502	621 E 85TH ST	90001	9	097-5A207 226	6029025009	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Expired	09/10/2023 12:00:00 AM	ADDRESS	33.96117	-118.26426	PV1 rooftop solar installation on (E) SFD.  (15) modules and microinverters. 3.75 kW AC system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39952	12041-10000-22447	22519 W DOLOROSA ST	91367	3	174B101   358	2040017021	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.17027	-118.61739	NEW 4.9 KW ROOF MOUNTED PV FOR A SINGLE FAMILY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39953	17041-10000-38760	4601 S BROADWAY 2ND FL	90037	9	112-5A203 274	5110009001	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.00182	-118.27861	INTERIOR REMODELING OF EXISTING OFFICE SPACEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39954	17041-20000-17392	9242 N KENNY CT	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.23876	-118.45912	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39955	17041-20001-35690	431 S HARVARD BLVD 1-43	90020	10	135B193   548	5503011023	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.06623	-118.30429	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 32.98 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39956	16041-10009-43714	1030 N SWARTHMORE AVE Bldgs 3;4;-5	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	Delta 59 changes to plans for Bldg 3 ( Sheet 03EP1.2.02) ; Bldg 4 (  Sheet 04EP1.2.02 ) ; Bldg 5 ( Sheets 05.EP1.2.02 and 05EP1.3.02 ). All  changes are clouded and marked on the sheets.(((((((((PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT. BUI;DING APPLICATION 16010-10000-04147	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39957	19041-10000-10947	695 S WESTERN AVE	90005	10	132B193   275	5093005034	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2126.10	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.06016	-118.30935	T-24, ENERGY ONLY PC FOR MCDONALD INTERIOR TI; MODIFY SERVICE COUNTERAND CEILING PLAN. SCOPE INCLUDES RELOCATING LIGHTING FIXTURES AND RECEPTACLE. TOTAL AFFECTED ARE IS 1900 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39958	10041-10000-14383	1436 S VERMONT AVE	90006	1	126B197    38	5056001057	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	01/04/2011 12:00:00 AM	ADDRESS	34.04527	-118.29141	Ti for a restaurant. Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39959	14041-10001-03871	1420 W SEPULVEDA ST	90732	15	018B193   492	7452002014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	33.74527	-118.30697	"""EXPEDITED PER APPLICANTS REQUEST""PV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. POWER OPTOMIZERS. ONE STORY. SYSTEM SIZE: 3.5 KW DC.(14) CANADIAN SOLAR # CS6P-250PX(14) SOLAREDGE OP300(1) SOLAREDGE SE3800A"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39960	16041-10000-40354	500-506 S SAN PEDRO ST	90013	14	127-5A213 248	5147025022	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.0439	-118.24387	PC FOR ENERGY. T.I. CHANGE OF USE ,OFFICE, MARKET AND RESTROOMS. TOTAL AREA 4196 SQ FT.B# 16016-10000-27392	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39961	12041-10000-20030	5243 N CAMPO ROAD	91364	3	171B105   601	2168003028	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.16449	-118.59815	NEW 1.17KW PV ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39962	17041-10000-33161	13237 N GLADSTONE AVE	91342	7	225B157   672	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Issued	09/15/2017 12:00:00 AM	ADDRESS	34.31154	-118.42954	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 9800 SQ.FT (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39963	15041-20000-43777	15465 W EL CAJON ST	91342	7	222B145   174	2604012006	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.30505	-118.46888	PV1, rooftop solar installation 6kW AC interconnects with 400MSP(28) KU2656ZPA(1) PVI-6000-OUTD-US-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39964	17041-10001-04608	20201 W RINALDI ST BLDG A2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Closed	02/12/2020 12:00:00 AM	ADDRESS	34.27512	-118.57373	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding site lighting, replacing exterior lights, revising title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39965	11041-20000-04940	22143 W SHERMAN WAY	91303	3	183B101    64	2023009016	C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.20119	-118.60957	PLAN CHECK POWER AND ENERGY FOR CHG OF USE FROM SFD TO DENTAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39966	16041-20001-41302	11735 WETHERBY LANE	90077	5	153B141   276	4377045006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/08/2017 12:00:00 AM	PIN	34.11172032	-118.4763532	09/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Chnages have been made to the SLD and the combination of the series-rated CBs.*****Previous Work Description*****upgrade service from 400 to 600 amps	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39967	18041-10002-07858	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			PC Approved	06/05/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	Plan check only. DELTA 5 CHANGES TO AN APPROVED SET. ADDITION OF CABLE LEGEND ON FA0.02 FOR THE CI CABKLES USED.  Original scope: Install New Fire alarm system on New 8 story hotel (note** plan check engineer to verify w/ number of story under 17010-10000-03362 and 16041-20000-44615), scope consists of (10) FA panels, and (707) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39968	17041-10000-13108	16940 W DEVONSHIRE ST	91344	12	204B133   217	2685002016	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.25735	-118.50161	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.  Total area = 454,175 sq. ft.  Extended counter plan check per N.M.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
39969	19041-20000-49576	14224 W NORDHOFF ST	91402	6	195B153    11	2639026009	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	06/04/2021 12:00:00 AM		Issued	06/04/2021 12:00:00 AM	ADDRESS	34.23517	-118.44278	Permit fees $62.89 due to California Senate Bill 1222 and AB 1414 PV3 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 28.38 KW DC/25.693 KW AC CEC. SCOPE OF WORK CONSISTS OF (86) PV MODULES WITH OPTIMIZERS, A 9 KW INVERTER, A14.4 KW INVERTER, AND A SUB PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39970	15041-10000-18996	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	PIN	34.12750533	-118.21285206	TI TO AN EXISTING COMMERCIAL BUILDING.  BATHROOM REMODEL IN LOCATIONS G16A, G16B, G23, 124,224,144,244,331.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39971	13041-10000-19439	3560 S WATT WAY UNIT B7	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.02169	-118.28671	APPLICATION IS FOR PLAN CHECK AND PERMIT.Remodel of laboratory space in USC Physical Education Building.  Newly connected load below 400 A, title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39972	19041-20000-53192	1116 N NAPOLI DR	90272	11	129B133   285	4408003002	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM			PC Info Complete	01/16/2020 12:00:00 AM	ADDRESS	34.04792	-118.5043	PC FOR POWER ONLY. SCOPE INCLUDES INSTALLING A NEW 800 AMP 120/240V  1 PHASE 3 WIRE SINGLE PHASE SERVICE, PANELS, EQUIPMENTS AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39973	15041-20000-16753	19248 W CANTARA ST	91335	3	192B117   892	2104002002	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	PIN	34.21906569	-118.55300154	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (24) modules. Standard plan in being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39974	14041-20000-08282	21540 W PLUMMER ST	91311	12	198B105    43	2746014042	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.24246	-118.59991	T.I. to an existing two-story office building.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39975	12041-20000-10456	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.24317	-118.50383	New PV system for greek church. 141.12 kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39976	16041-10000-40915	3917 S EDGEHILL DR	90008	10	117B185  1094	5033007017	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.01412	-118.33153	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(11)MODULES-SUNMODULE SW 340 XL MONO(1)INVERTER-SMA SUNNYBOY 3800	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39977	14041-10001-06207	11267 N ADELPHIA AVE	91331	7	210B165   129	2532024026	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	03/16/2014 12:00:00 AM	ADDRESS	34.27491	-118.39802	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(8) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39978	15041-10000-18219	5825 W CAMERFORD AVE 1-34	90038	13	141B189   175	5534034017	R3-1XL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			06/11/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.0845	-118.3253	pc for power and energy. apartment structure with 3 levels of Type VA construction above grade and 1 level Type I garage below grade. 34 residential units. total area 30311 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39979	11041-10000-14326	11321 W MISSOURI AVE	90025	11	126B149   509	4261021013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			07/11/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.04226	-118.44566	NEW FIRE ALARM SYSTEM FOR A 3-STORY APARTMENT COMPLEX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39980	19041-20000-33741	2581 N WALLINGFORD DR PV1	90210	5	153B153    16	4382007046	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.11951	-118.43391	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 22.77 KW DC/19.75 KW AC. SCOPE OF WORK CONSISTS OF (69) PV MODULES WITH MICROINVERTERS, (2) SUB PANELS, AND (2) BATTERIES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39981	19041-20003-30529	6050 N ELLENVIEW AVE	91367	3	177B085   282	2032015025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.1812	-118.65949	NEW ROOF MOUNTED 16.38 KW PV SYSTEM WITH 52 @ PV PANELS, 2 @ POWER WALLS AND 2 INVERTERS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39982	18041-10000-01006	22828 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	34.18625	-118.62435	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 5990 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39983	10041-20000-13072	11442 W DONA CECILIA DR	91604	2	159B169   724	2381009017	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	34.12816	-118.38377	PLAN CHECK FOR 12 KW PV SYSTEM FOR SINGLE FAMILY DWELLING. NON-ROOF MOUNTED PV MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39984	19041-20000-37099	8727 N TAMPA AVE	91324	12	195B117   176	2783027022	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM			Reviewed by Supervisor	10/23/2019 12:00:00 AM	ADDRESS	34.22905	-118.55376	PC FOR POWER AND ENERGY.  (FIRST TIME TENANT OF A CHANGE OF USE FROM OFFICE TO HYDROPONICS). SCOPE OF WORK INCLUDES SERVICE UPGRADE TO 2000A, NEW PANELS, NEW TRANSFORMERS, NEW LOADS, NEW LIGHTS, T24 INCLUDED, TOTAL SQUARE FOOTAGE = 9870 SF(BUILDING PERMIT UNDER 19016-20000-26197)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39985	18041-20000-12316	11408 W ALBATA ST	90049	11	135B145   685	4365017002	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.06362	-118.4613	Plan check for PV roof mounted system. system size: 4.7kW with 17 modules and 17 microinverters. l	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39986	19041-10001-03048	16927 W MOONCREST DR	91436	5	165B133   387	2292004003	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM			PC Approved	02/11/2019 12:00:00 AM	ADDRESS	34.14706	-118.50223	PC FOR ROOFTOP PV SYSTEM 10.6KW AC. SCOPE OF WORK INCLUDES (44) 325W PV MODULES WITH P400 OPTIMIZERS, (1) 3KW AC INVERTER, AND (1) 7.6KW AC INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39987	15041-10000-09823	515 S FLOWER ST FLR 43-44	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI TO AN EXISTING HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 46423. SCOPE OF WORK TO BE PERFORMED IN FLOOR 43 AND 44	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39988	12041-10000-19234	3235 W 59TH PL	90043	8	105B185   175	4005006010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Expired	10/13/2014 12:00:00 AM	ADDRESS	33.9864	-118.3291	PLAN CHECK 1.88KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM (GROWATT TRANSFORMERLESS INVERTER)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39989	17041-10000-18347	304 S BROADWAY #400	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Info Complete	06/02/2017 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR TITLE -24 ENERGY ONLY FORTI IMPROVEMENT OF EXISTING OFFICE. TOTAL AFFECTED AREA 2923 SQ.FT.INSTALLING NEW LIGHTS AND RECEPTACLESBLD # 17016-10000-14348	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39990	16041-20001-32984	5419 N CORBIN AVE	91356	3	174B117   650	2164010039	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.16912	-118.56284	Revisions to approved online permit plan set.  Addition of (5) AC modules for a total of (31) AC modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39991	18041-30000-01526	1000 W WILSHIRE BLVD 17th Floor	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for Title 24 only in existing high-rise building 17tgh Floor Office T.I. Total area:9,000 sqftB#18016-10000-01259	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39992	15041-20000-09435	4143 N ALEMAN DR	91356	3	165B113   198	2178004043	A1-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.14525	-118.56502	PV1 SFD TOTAL SYSTEM SIZE 6KW USING STANDARD PLAN. TOTAL OF 32 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
39993	15041-10000-17801	1209-1215 S BEDFORD DR Street	90035	5	132A165   174	4330007***	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			06/09/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.05585	-118.40493	NEW FIRE ALARM SYSTEM 160 DEVICES FOR AN APARTMENT BUILDING, Bedford Street not Bedford Drive	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39994	12041-10002-10297	17941 W CHATSWORTH ST	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM			PC Approved	10/19/2012 12:00:00 AM	ADDRESS	34.26503	-118.52485	Revision to the approved plan. Change the luminaire control to a time clock. EPC is for delta 2. (((((((((Ti for a restuarant, one story, stand alone.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39995	12041-20000-07095	20000 S WESTERN AVE	90018	15	057B193     4	7351003012		Harbor				2920.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	PIN	33.85037211	-118.3072945	new tenant office space	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39996	11041-20000-14524	11611 W SAN VICENTE BLVD # 710	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	add 9 lights in coridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
39997	13041-10000-27121	17352 W NAPA ST	91325	12	192B133    39	2787025033	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.22642	-118.51159	PV1. ROOF MOUNTED 8.82 KW PHOTOVOLTAIC SYSTEM . STANDARD PLAN.(36) YINGLI # YL245P-29B(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
39998	12041-10000-08587	10850 W NATIONAL BLVD	90034	5	123B157  1152	4254008003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	PIN	34.02994066	-118.42137081	New 800A service split for a new bank and an existing grocery store.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
39999	12041-10000-23719	800 W 6TH ST	90017	9	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Public Safety Only			10/04/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.05011	-118.2577	FOR AN EXISTING HIGH RISE BUILDING , UPGRADE FIRE ALARM PANEL  AND ADD NEW TRANSPONDERS-ONE FOR -ONE CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40000	17041-10000-20525	4089 S LINCOLN BLVD	90292	11	108B149  1645	4229005097	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	33.98834	-118.44602	Title 24 plan check.  T.I. to existing restaurant and bar with no change of use.  Existing 400 amp service to remain existing with 2 new subpanels.  New lighting, receptacles, and HVAC.  Lighting area = 3,040 sq. ft. (indoor) + 17,620 sq. ft. (outdoor).       Building permit #17016-10000-11630	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40001	18041-10000-15077	7600 N BALBOA BLVD STE 109	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	T-24 PC, CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE OF WORK INCLUDES NEW PANELS, LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1776.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40002	19041-10000-38592	26008 S WESTERN AVE	90710	15	033B193   336	7411008045	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	33.78648	-118.30788	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40003	18041-20000-09549	24770 W CALVERT ST	91367	3	177B085   143	2032029024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2018 12:00:00 AM	04/02/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.18317	-118.66551	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17.25 KW$0 PERMIT FEE PER STATE SENATE BILL SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40004	18041-10000-16403	10250 W SANTA MONICA BLVD # 2060	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Issued	08/29/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check (Power+Energy), for tenant ""OLD NAVY"" ste#2060, install(3) panelboards, 75 kVA transfomers. Total area under the scope: 8,153 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40005	15041-10001-02084	11526 W BURBANK BLVD	91601	2	174B169   866	2350004039	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM			PC Approved	04/08/2015 12:00:00 AM	ADDRESS	34.17199	-118.3832	Supplemental spplication for expedite fees.Installation of new roof mounted solar PV array on existing commercial property.  Total system size = 16 kWac.  2 inverters with 68 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40006	16041-20001-01652	10697 W SOMMA WAY	90077	5	144B149   173	4370006079	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.09107	-118.45223	08-12-2019 Changes to an approved set of plans, Changes include increase Service size: 1,200A, additional 5 panels and associated load. Significant redesign to the single line diagram and floor plan and change engineer of record. ((((((((Plan check for power. Project site is a new 2-story, single family dwelling. Work includes a 600-amp service, (6) panels, and associated loads.Note: Building permit has been issued under 13010-10000-03127.  Electrical permit fees paid as part of building combination permit.))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40007	11041-10000-17713	1005 S FAIRFAX AVE	90035	10	132B177   657	5086001040	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM			PC Approved	11/28/2011 12:00:00 AM	PIN	34.05800719	-118.36424409	T-24 lighting plan check only for remodeled Carls Junior.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40008	19041-10000-32821	3400 S FIGUEROA ST	90007	9	120A203   222	5123022040	USC-1B	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.02167	-118.2799	T-24 PLAN CHECK FOR A TI TO USC GALEN CENTER. REPLACING METAL HALIDE FIXTURES FOR ARENA  AND SEATING LIGHTING WTH NEW LED FIXTURES USING EXISTING CIRCUITS AND CONTROLS. TOTAL AFFECTED AREA IS 96000 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40009	19041-20000-44787	5425 N ALDEA AVE	91316	5	174B133   788	2258001023	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM			Reviewed by Supervisor	11/13/2019 12:00:00 AM	ADDRESS	34.16985	-118.50821	PV1. INSTALL 12.285 KW DC PV SYSTEM WITH (39) MODULES/OPTIMIZERS, (1) INVERTER (SE11400H) AND (4) TESLA ENERGY STORAGE BATTERIES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40010	10041-10000-13475	5945 W PICO BLVD	90035	5	129B173   299	5087022030	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.05223	-118.36949	TENANT IMPROVEMENT IN A CESAR PIZZA TAKE-OUT RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40011	16041-10000-45124	5001 W RODEO ROAD	90016	10	120B181   948	5046013900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	02/28/2020 12:00:00 AM	ADDRESS	34.02168	-118.35178	CONSTRUCTION OF SPORTS ARENA, PRESS BOX AT 2ND STORY LEVEL; TICKET OFFICE, & CONCESSIONS STORE AT 1ST STORY LEVEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40012	19041-10000-09654	1949 N GAFFEY ST	90731	15	024B197    78	7442022021	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.76329	-118.29349	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40013	17041-20001-23707	3274 S VETERAN AVE	90034	5	120B157   501	4254020020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.02511	-118.42006	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system w/AC coupled battery backup system (on SFD).System size: 6.16kW ungrounded.(22) EnPhase IQ6PLUS microinverters.(22) 320W pv modules.(1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40014	18041-20000-28779	2748 W 8TH ST Suite 101	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.05747	-118.28552	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,199 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40015	13041-10001-24379	7221 N CLYBOURN AVE	91352	2	183B177    28	2410021008	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.20194	-118.36251	CONSTRUCTION OF PHOTO STUDIO. EMPTY WAREHOUSE AND PARKING GARAGE. PC FOR T24 ENERGY ONLY. TOTAL AREA 3400 SQ FT.(5/6/14) Change in archetecture resulting in new title 24 - Bathrooms and support rooms are moved, fixtures remain the same, lighting and photometrics slightly changed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40016	18041-10000-37139	10720 W AYRES AVE	90064	5	126B157   992	4255027005	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.03983	-118.42447	NEW ROOF MOUNTED 6.84 KW PV SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40017	19041-20000-41379	11853 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	09/26/2021 12:00:00 AM	ADDRESS	34.2858	-118.38962	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40018	10041-10000-10181	8130 N REMMET AVE 8130, 8200-, 8220	91304	3	189B105    28	2110003040	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	05/28/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.21737	-118.60014	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40019	17041-10000-36851	3932 W WILSHIRE BLVD	90010	10	132B193    76	5092030009	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.06153	-118.31244	REPLACE OUTDOOR HID EXISTING FIXURE WITH NEW LED FIXURE - TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40020	11041-20001-21797	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.32381	-118.49103	Modification to an approved set of plans.  The modifications are to the lighting control.  Indicating on plans were the censors / dimmers are located and also where the switch bank is.  <<<<<<T.I.  Office remodel of the light fixtures.  Plan check is for energy only.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40021	11041-20000-22573	16917 W ENADIA WAY	91406	12	183B133   223	2227026023	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.20024	-118.50181	T.I.  Medical office.  Adding new panels / circuits to an exsting service.  Two panels are for emergency only. One is for Life & Safety and the other is for Critical.  Plan check is for energy and power. Not plan reviewed for OSHPD III	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40022	12041-10000-22947	12427 W ROCHEDALE LANE	90049	11	138B137   357	4494009008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2012 12:00:00 AM			PC Approved	09/26/2012 12:00:00 AM	ADDRESS	34.07329	-118.48622	New 7.9KW roof mounted PV for a single family (permite pulled under# 12041-10000-1812)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40023	17041-10000-22036	515 S FLOWER ST SUITE 900	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Issued	07/25/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	T.I. 18,579 SF. offices. loads less than 400A. PC FOR ENERGY ONLY T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40024	16041-10000-41014	1677 N DOHENY DR	90069	4	147B169   102	5561006008	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.10151	-118.38827	PC power only to a new single family home, two floors plus basement.  Installing new service rated at 600 Amps. All new equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40025	17041-20004-17242	611 S GAYLEY AVE	90024	5	135B149   217	4363006021	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			10/29/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.06777	-118.44876	10/29/2018changes to an approved set of plans.  changes to relcate plugs and electrical equipment.  changes noted delta 2 in first floor only.  this is plan check only.  ((((Plan check for power and energy. New 22-unit, 4-story student dormitory over 2-levels of parking. 800A service. T24 area: indoor - 20,069sqft; outdoor - 4,719sqft.Building permit filed under 15010-10000-01460.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40026	15041-10000-05310	2620 S CRENSHAW BLVD	90018	10	123B185   823	5051007004	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	PIN	34.03183843	-118.33468853	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 7696 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40027	12041-10000-10222	11668 W SHERMAN WAY	91605	6	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	09/25/2012 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.20103	-118.38683	Change to lighting and relocating receptacles at an existing 3-story, testing Laboratory.  Load is less than 400A per applicant.  PLAN CHECK ONLY for Energy, no emergency lighting.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40028	16041-10000-23791	1023 S ABBOT KINNEY BLVD	90291	11	109-5A143 439	4239021027	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	33.99219	-118.47181	PC for energy only to an existing restaurant, TI. Installing a new switchboard rated at 400 amps and new panel. Newly connected load is less than 400 amps. Intalling new lighting. Total sqft = 2575	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40029	14041-10001-10981	6007 S ST ANDREWS PL	90047	8	105B193   569	6001018009	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	33.98484	-118.3116	((6/5/2014- CHANGES MADE TO SCOPE. ADDED LIGHTING AND NEW CIRCUITS. PERMIT HAS TO BE PULLED ON THE MASTER APPLICATION UNDER INSPECTION. ORIGINAL PLAN CHECKER IS ABDEL ITANI))) plan check for power. CORE/SHELL FOR (E) 2 STORY BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40030	10041-10000-17590	523 W 6TH ST 640,644,-648	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	PIN	34.04872199	-118.25441618	Ti in an existing office building. Plan check for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40031	12041-10000-14108	1625 W WILSHIRE BLVD	90017	1	132A205   392	5142009035	C2-2, C4-2, R4P-2, R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.05609	-118.27124	Plan check for energy and emergency lighting. 6061 combined sqft (1956 indoor). McDonalds. Methane Buffer Zone per building permit 12016-10000-03065 but no underground work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40032	17041-10000-16989	8431 N PINELAKE DR	91304	12	192B093   165	2005015013	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.22213	-118.63767	PC FOR ROOF TOP  PV SYSTEM USING 39 MODULES, POWER OPTIMIZERS AND 11.4KW AC SOLAR INVERTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40033	12041-20000-17629	7815 N TAMPA AVE	91335	3	189B117   768	2105022020	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	09/07/2012 12:00:00 AM	ADDRESS	34.21263	-118.55374	Roof mounted P.V. system using Enphase M215 inverters, install two new subpanels for connection of two enphase circuits, and a subpanel to relocate two 15 ampere circuits from the service panel to allow room on the service panel for the PV dedicated circuit breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40034	16041-10000-19055	6245 W WILSHIRE BLVD	90048	5	135B177   482	5510027014	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Closed	03/15/2018 12:00:00 AM	ADDRESS	34.06356	-118.36478	PC for temporary power for mixed use apartment/retail highrise bulding located in methane zone. Scope includes a new switchboard  480/277V, 3phase, 4Wire rated at 1200 amps and adding new load equipment.  Note: Conduit only permit under 16041-10000-21570	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40035	19041-10000-53783	12548 W VENTURA BLVD	91604	2	162B161   238	2384023056	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			Reviewed by Supervisor	01/06/2020 12:00:00 AM	ADDRESS	34.14276	-118.40684	"FULL PC FOR A NEW MIXED USE BUILDING. SCOPE OF WORK INCLUDES A NEW 3000A SERVICE (480/277V, 3P ,4W) WHICH FEEDS THREE SWITCHBOARDS ALL RATED AT 1000A, SWITCHBOARD ""MS3"" FEEDS 3 SUBPANELS WITH 3 TRANSFORMERS. TOTAL AFFECTED AREA 84,588 SQFT.********************************************NEW 4-STORY MIXED USE BUILDING, INCLUSIVE OF TWO LEVELS OF ABOVE-GROUND PARKING1 OF 7BUILDING PERMIT #19010-10000-06424"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40036	14041-10001-27373	12887 W HAMMOCK LANE	90094	11	102B157   397	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	33.97471	-118.42039	Changes to approved set.  New module layout on roof.*****Previous Work Description*****Installation of new roof mounted solar PV system.  Total system size = 3.8 kWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40037	13041-10000-35266	1300 S SAN PEDRO ST ST # 106	90021	14	123A211    69	5132019001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	PIN	34.03251075	-118.25377188	Plan check for T24 only. Changing  fixtures with existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40038	12041-10000-06556	3785 W WILSHIRE BLVD #1 & 2	90010	10	135B193  1040	5503030BRK	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	04/02/2012 12:00:00 AM		Permit Finaled	05/31/2012 12:00:00 AM	ADDRESS	34.06187	-118.30858	FIRST -TENANT IMPROVEMENT TO NEW RETAIL SPACE (1,835 SQ FT) ON THE GROUND FLOOR :TENANT PANEL BOARD AND SOME CIRCUITS WERE APPROVED ON THE CORE AND SHELL PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40039	17041-10001-31938	20221 S HAMILTON AVE	90502	15	054B197    33	7351033022	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	33.84695	-118.28626	SUPPL PERMIT FOR ADDITIONAL 64 DEVICES TO THE EXISTING Fire alarm system in an (E) 2 story commercial build.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40040	13041-10002-05747	380 WORLD WAY Space T64	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	changes to approved plans: adding ckt 4T-64:26 for 4 receptacles. floor plan E2.1 and SLD updated under delta 15supplemental 1: shows more detail about the location of  partial fourth floor storage room electrical plan. also shows that kitchen table/counter actually includes a load center. PROPOSED 803 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Scoreboard LA).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40041	17041-10006-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	DELTA 3 Changes to approved set for series rating of 3 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40042	18041-10000-34772	3562 S LA CIENEGA BLVD	90016	10	120B173   495	5047002064	C4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.02234	-118.3721	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40043	16041-10000-26006	1111 S FIGUEROA ST	90015	9	127-5A207 248	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.04338	-118.26581	Plan check for T-24 only. TI on (E) commercial building (Staple Center). Convert office space into lounge area.  Install new lights and receptacles. Total affected area: 6,053 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40044	18041-20000-34487	20655 W BEECH CIR #327	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.29271	-118.5842	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40045	11041-10000-21336	7106 S TRASK AVE	90293	11	096B153   907	4116020025	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	33.95709	-118.44509	Photovoltaic system, Enphase microinverters, SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40046	18041-20000-48473	5555 W MELROSE AVE Lewis	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for replace electrical distribution like to like Medium Voltage 2.4kV 2500A, 600A, 400A distribution, and new 15 panels in Building # Lewis. no new load added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40047	17041-30000-05556	4955 N VAN NUYS BLVD Suite 719	91403	4	169-5A151  13	2263026046	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.16078	-118.4489	Plan check for power and energy. Project site is an existing ambulatory surgery center. Project scope is a tenant improvement. Total lighting area = 952 sq. ft.Note: Building permit has been issued under 17016-10000-01576	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40048	15041-10000-16282	3700 N COLDWATER CANYON AVE 1ST FL	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.13809	-118.41286	NEW LUMINAIRES IN OFFICES IN THE CHALMERS HALL ON THE HARVARD WESTLAKE CAMPUSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40049	16041-10000-42765	17318 W TRAMONTO DR 1-4-Bldg 6	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	11/23/2020 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building 4 story 4 units (Type B) .  With 1 service 4,000A feeding all 9 buildings. Performance method is being use for Title 24. Total area: 16,235 sq ft.Note: This is 9 buildings submit  in 1 plan. 6 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40050	15041-20000-11668	970 W 190TH ST Suite 350	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	33.85812	-118.29302	Plan check for title 24 only for existing commercial office remodel. Total area: 389 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40051	14041-10000-24450	940 N MALTMAN AVE	90026	13	142-5A203 171	5427022021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	10/30/2014 12:00:00 AM	ADDRESS	34.08556	-118.27997	PV1, INSTALL 5.865 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(23) MODULES: KYOCERA KD255GX-LFB3(1) SOLAREDGE SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40052	16041-20000-42358	1901 S FIGUEROA ST	90007	9	124-5A205 194	5126003016	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.0343	-118.27237	Plan check for power and energy. Phase II submittal of new Toyota parking structure - showroom area and offices on floors 1 and 2. 20,571sqft. Phase I (rest of building) plan checked under application #16041-20000-06953.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40053	14041-20001-06427	4365 N MAMMOTH AVE 1-24	91423	4	165B153   378	2271017027	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	34.15002	-118.43269	Fee for expedite only*****Roof mounted PV system with 32.94KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40054	14041-10000-13447	8736 S SEPULVEDA BLVD # C	90045	11	096B165   851	4123002004	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	33.95776	-118.39597	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT OF (E) OFFICE SPACE INTO SUSHI RESTAURAN. TOTAL AREA 2050 SQ FT.BUILDING APPLICATION # 14016-10000-07912.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40055	16041-10000-37019	11101 S HINDRY AVE	90045	11	087B173    57	4129037010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	33.93388	-118.37248	PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 23700 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40056	16041-20000-41113	7342 N LASAINE AVE	91406	6	186B133   856	2228015023	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Issued	11/21/2016 12:00:00 AM	ADDRESS	34.20409	-118.51076	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40057	18041-20000-22193	22622 W VANOWEN ST	91307	12	180B097    33	2038020063	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.19355	-118.61959	Plan check for Title 24 only. Project site is an existing Career Center in a high school. Project scope is a tenant improvement. Total lighting area = 1,015 sq. ft.Note: Building application has been generated under 18016-20000-10525	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40058	12041-10000-04614	9301 N TAMPA AVE #216	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Change of use from commercial to a new restaurant.  New switchboard,  panels,  loads, circuits, receptacles, lighting.  Variance will be submitted to seperate the fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40059	17041-10002-18404	19862 W VINTAGE ST	91311	12	204B113   725	2726005001	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Issued	07/06/2018 12:00:00 AM	ADDRESS	34.25166	-118.56633	CHANGES TO THE APPROVED PLANS FOR ADDING A PV METER.<<Installation of new roof mounted solar PV system on existing single family dwelling.  AC module system.  Total system size = 10.8 kWac(30)AC Modules-SPR-X22-360-C-AC>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40060	15041-20004-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM			PC Approved	06/29/2017 12:00:00 AM	ADDRESS	34.25734	-118.50614	Changes to approved set of plans. changes noted (delta 6/12/17).  changes to reflect field conditions.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40061	15041-20001-37172	1107 N BRONSON AVE	90038	13	144B189   644	5534010009	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM			PC Approved	04/22/2016 12:00:00 AM	ADDRESS	34.09102	-118.31808	4.22.2016 - Plan check for modifications to approved set. Relocate existing 400A service board. Update voltage drop and fault calcs, and floor plan.===Plan check for power and lighting. Project site is an existing commercial building (rock-climbing gym). Building occupancy is A3 with an occupant load of 246. Project scope is a tenant improvement. Total lighting area = 20,590 sq. ft.Note: Building permit has been issued under 14016-10000-21613	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40062	16041-10000-10003	1245 W WILSHIRE BLVD # 635	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	FULL PC FOR POWER AND ENERGY. TI TO AN (E) MEDICAL OFFICE BUILDING FOR SUITE 635. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR EXAM ROOMS (GENERAL CARE/ NON INVASIVE PROCEDURES) AND OFFICE SPACE. TOTAL AFFECTED AREA IS 1501 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40063	12041-10001-08563	3300 S FIGUEROA ST	90007	9	120A203   166	5123021001	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.02272	-118.27924	"T.I. to an existing car dealership, Replace ceiling lighting fixtures and relocate receptacles.  No new load added per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit to relocate 150A panel and relocate 30 receptacles is under ""Inspection"" fees.  <<<INVESTIGATION FEES DUE ARE ADDED TO THIS PERMIT>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40064	13041-20000-13709	3470 S TROUSDALE PKWY	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.02202	-118.28393	Change to switching in an existing classrooms.  NOT A PLACE OF ASSEMBLY PER APPLICANT.  All lighting fixtures are existing on dimmers.  Plan Check Only for Mandatory Measures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40065	19041-10000-46126	1801 CENTURY PARK EAST 23RD FLR	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Info Complete	11/08/2019 12:00:00 AM	PIN	34.0621869	-118.41581732	T-24 ENERGY PC FOR OFFICE T.I. LOCATED ON THE 23RD FLOOR. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT. TOTAL AFFECTED AREA 13262sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40066	11041-20000-26497	330 W 11TH ST	90015	14	126A209   297	5145022001	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM	ADDRESS	34.04114	-118.26167	Existing commercial space parking lot.  Adding new outdoor light fixtures for the parking lot.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40067	11041-20000-21076	7045 W LANEWOOD AVE	90028	4	147B181   419	5548012009	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			10/03/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.09933	-118.34304	PLAN CHECK FOR NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40068	10041-20000-25346	4955 N VAN NUYS BLVD	91403	2	169-5A151  13	2263026046	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02, 1289.10	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Issued	03/22/2011 12:00:00 AM	ADDRESS	34.16078	-118.4489	"fire alarm medical building.""COMPLY WITH DEPARTMENT ORDER effective date01/16/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40069	15041-10000-27068	5959 W CENTURY BLVD Suite1400	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	33.94571	-118.38857	Energy plan check for an office (suite 1400) T.I , located a a high rise building; Scope includes new receptacles and lighting. Total area is 5480-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40070	18041-10000-16889	15814 W STRATHERN ST	91406	6	189B141    82	2206003006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.21559	-118.47807	Replacing existing hid fixtures with new LED Fixtures.T-24 Energy Only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40071	13041-20000-21757	6811 N HAZELTINE AVE	91405	6	183B153  1082	2217014081	[Q]C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.19451	-118.44016	Plan check for energy only. Outdoor lighting. Permit is on 13041-30000-21757.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40072	17041-10000-27195	13851 W FOOTHILL BLVD	91342	7	225B153   365	2509002038	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.31123	-118.43486	TITLE 24 PLAN CHECK FOR REPLACEMENT OF (13) EXISTING FIXTURES AND REPLACING WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 19900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40073	19041-20000-35746	23251 W KESWICK ST	91304	12	189B093   739	2027037005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.21033	-118.63408	PV1.  Install 12.285 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (39) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40074	10041-20000-20963	13622 W WYANDOTTE ST 1-33	91405	2	186B157   564	2328006016	R3-1	South Valley	Van Nuys - North Sherman Oaks			1271.01	Electrical	Electrical	Apartment			10/21/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	11/17/2010 12:00:00 AM	ADDRESS	34.20283	-118.42963	Install general lighting in parking garage.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40075	12041-20000-14170	4959 W SANTA MONICA BLVD	90029	13	144B197   728	5540009008	C2-1D	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	05/03/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.09098	-118.29784	Change of use from retail to restaurant.  New 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40076	15041-20000-29743	11601 W WILSHIRE BLVD SUITE 1650	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	PIN	34.0509267	-118.45996763	Plan check for energy only. TI to office on 16th floor. New lighting (incl. emergency). 4,435sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40077	15041-10000-43620	633 W 5TH ST 40TH FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40078	19041-10000-03692	212 N BAILEY ST	90033	14	129A221    76	5174008026	[Q]R5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.04858	-118.21754	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40079	13041-20000-10972	23323 W LEONORA DR	91367	3	171B093   764	2044022018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.16148	-118.63511	PV1 2 STORY SINGLE FAMILY DWELLING. MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24KW. [MICROINVERTER: ENPHASE M215-60-2LL] [SOLAR MODULE: SOLAR WORLD SW 255 MONO]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40080	14041-20000-33310	7653 N TEXHOMA AVE	91325	12	186B129    66	2202002019	RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Expired	12/26/2016 12:00:00 AM	ADDRESS	34.21006	-118.51549	PC AND PERMIT FOR CHANGE IN PV SYSTEM DESIGN. SYSTEM IS STILL A 21.8KW AC SOLAR. PC INCLUIDES LAYOUT CHANGES AND AN ADDITIONAL OF PV ONLY SUBPANEL.ORIGINAL PERMIT UNDER APPLICATION #14041-20000-28307	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40081	15041-20001-40370	7631 W BECKETT ST	91042	7	204A197   283	2558035021	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM			PC Approved	12/06/2015 12:00:00 AM	ADDRESS	34.25381	-118.299	Expedited plan check fee per applicant request.  PV1.  Install 5.16 kW roof-mounted, utility-interactive PV system.  (21) Silvantis F-Series 270W w/ (1) SolarEdge SE5000A-US transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40082	11041-10000-12744	100 W WORLD WAY WEST TERMINAL-# 1	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/26/2011 12:00:00 AM	PIN	33.94386803	-118.39979044	REPLACEMENT OF 4 ELEVATORS IN TERMINAL 1 AT LAXPLAN CHK IS REQUESTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40083	13041-20000-32466	22839 W DOLOROSA ST	91367	3	174B097   712	2042002010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.17023	-118.62473	PV1 MICROINVERTER. MAIN BUS IS 400A. 6.8KWAC. 26 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40084	19041-30000-21572	12013 W WILSHIRE BLVD	90025	11	129B145  1047	4265014105	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.04562	-118.46589	Plan check for power only. Project site is an existing commercial tenant space. Project scope is a change of use from massage parlor to dental office.Note: Building application has been generated under 19041-30000-17068.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40085	13041-10000-33321	7223 N BERNADINE AVE	91307	12	183B093    71	2027011017	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2013 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.20111	-118.63889	PV1, STANDARD SOLAR SYSTEM, ROOF-MOUNTED , (4) STRINGS, (9.26) KW DC. INTERCONNECT WITH SERVICE PANEL, (44) MODULES: TRINA PV  TSM-240PA05. (2) INVERTERS: SUNNY BOY SB4000TL/SB5000TL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40086	13041-10000-06519	10000 N ETON AVE	91311	12	204B105   773	2747007041	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.25194	-118.59498	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW. USING 33 MODULES. CENTRAL INVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40087	18041-10000-46116	5323 S WESTERN AVE UNIT B	90062	8	108B193   507	5005030031	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	33.99363	-118.30909	PLAN CHECK FOR TITLE 24 FOR - CHANGE OF USE FROM RETAIL TO RESTAURANT; TI, BUILDING WALLS, CLG; PLUMBING AND ELECTRICAL TO ACCOMMODATE NEW DONUT SHOP - TOTAL AFFECTED AREA = 1263 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40088	15041-20002-23492	6817 W FRANKLIN AVE	90068	4	150A185   287	5549018024	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			PC Approved	03/17/2017 12:00:00 AM	PIN	34.10444099	-118.33917245	03/17/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta H. Changes include the renaming of panels to match field conditions and the relocation of panels.*****Previous Work Description*****CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE ADDING NEW LOAD AND PANELS.  CHANGES NOTED DELTA B AND C*****Previous Work Description*****SERVICE UPGRADE TO 1200 AMPS.  RECONNECT EXISTING LOADS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40089	16041-20001-28837	14915 W ROSCOE BLVD	91402	6	192B149   371	2653023013	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.06	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.22163	-118.4582	Revision to approved plans: change of (E) service voltage class from 3ph-4w 240/120V delta to 3ph-4w 208Y/120V wye system.  PV OCPD rating adjusted.(((PC FOR 10KW AC USING 32 MODULES. CENTRAL INVERTER SYSTEM CONNECTED TO 3 PHASE SERVICE.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40090	19041-10000-06425	1000 W TEMPLE ST	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Apartment			04/05/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Issued	09/18/2019 12:00:00 AM	ADDRESS	34.06171	-118.25046	PC FOR A NEW FIRE ALARM IN A  SEVEN STORY MIXED USE BUILDING WITH TWO LEVELS OF SUBTERANEAN GARAGE. SCOPE INCLUDE 5715 FA DEVICES and 31 rps's.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40091	19041-10001-04929	23037 W OXNARD ST	91367	3	177B097   453	2039008026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.17934	-118.62886	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40092	14041-10000-03180	904 W DICKSON ST	90292	11	105B149   314	4229009040	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	33.9869	-118.45048	PV1.  Install 3.50 kW roof-mounted PV system, interconnect with main service panel.  14 modules: Rensola JC250M-24/Bb.  Transformerless inverter: SolarEdge SE3800A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40093	12041-10000-14317	9301 N OAKDALE AVE	91311	12	198B113   113	2761040019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.23936	-118.56702	T.I.  INTERIOR NON STRUCTURAL REMODEL TO (E) OFFICE (8,900 SF) ON THE 2ND FLOOR.  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40094	15041-10000-27101	12452 W OSPREY LANE Unit #1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	PV2 installed roof mounted pv system for UNIT#1. Size 3KW, interconnected with the main service panel.(8)modules: SPR-230NE-BLK-D(1)PVI 3.0-OUTD-S-US inverter*****zone clearance for this application shall also covers Unit #2, and Unit #3 under this address.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40095	17041-20000-17382	14260 W VENTURA BLVD #300	91423	4	165B153   391	2266002005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.14996	-118.44407	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES "" CORAL LUTZA PROPERTIES"" 4051 SQFT.  UNIT 300"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40096	15041-20000-03085	700 S FLOWER ST SUITE 2900	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Issued	02/04/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 29TH FLOOR. SUITE 2990. 9033 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40097	19041-20000-40778	11214 N GLORIA AVE	91344	12	210B141   296	2666025008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.27407	-118.47967	PV roof mounted system, PV system size: 5.28KW DC 4.86KW AC  CEC with 16 PV Modules  16 microinverters, Tesla power Wall 2.0, 2 sub-panels	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40098	14041-10000-09901	2202 S FIGUEROA ST	90007	9	123A205    72	5126006013	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.03134	-118.27373	Title 24.  Remove HID light fixtures and replace with new fluorescent fixtures.Total area = 1635 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40099	19041-20000-34157	20606 W WOOD ROSE CT	91326	12	219B109   548	2701102038	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.29531	-118.58271	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40100	14041-10000-21340	14402 W CALIFA ST UNIT #13	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.17739	-118.4467	PV1. ROOF MOUNTED SOLAR SYSTEM. MICROINVERTER. SYSTEM SIZE: 5KW DC.   UNIT # 13(20) TRINA SOLAR MODULES(20) M215 ENPHASE INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40101	17041-20000-18324	9243 N KENNY CT	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.23877	-118.45932	Plan check for solar pv system, roof-mounted on SFD.3.84kW ungrounded sysetm. (12) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40102	18041-20001-05547	13062 W TERRA BELLA ST	91331	7	204B161    72	2623002013	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2018 12:00:00 AM			Re-Activate Permit	09/17/2018 12:00:00 AM	ADDRESS	34.25866	-118.41761	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac/5.61 kWdc and consists of (1) inverter and (17) modules. MSP is center-fed. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40103	18041-10000-45899	15220 W RAYMER ST	91405	6	189B145   461	2209032041	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.21419	-118.46455	REMOVE OUTDOOR/INDOOR EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40104	19041-10001-44936	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM			PC Info Complete	11/18/2019 12:00:00 AM	ADDRESS	34.10299	-118.25902	NEW ROOF MOUNTED 134.85KW PV SYSTEM WITH 310 PV PANELS TWO CENTERAL INVERTER ON A COMMERCIAL BULDING.PERMIT IS $ 0 due to SB 1414	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40105	13041-10000-12515	819 S SANTEE ST	90014	14	126A211    46	5145013005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			05/14/2013 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.04107	-118.25233	CHANGE OF USE OF AN EXISTING 93,379 SQFT, 13-STORY BUILDING W/ BASEMENT INTO JOINT LIVING AND WORK QUARTERS PER THE ADAPTIVE REUSE ORDINANCE.  (TOTAL 96 UNITS). fire alarm variance NEEDS TO BE FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40106	17041-20001-08719	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			PC Approved	04/12/2017 12:00:00 AM	ADDRESS	34.17705	-118.6144	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 70 KW. (223) WINAICO WSP 300 MODULES(3) SYMO 12.0 (3) SYMO 10.0	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40107	11041-10000-15989	10690 N BALBOA BLVD	91344	12	207B133   519	2684001039	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.26461	-118.50206	T.I.  Existing 7-11.  Replacing the existing light fixtures in the retail are only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40108	17041-10000-07775	521 S LORENA ST	90063	14	123A227   157	5186008008	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.20	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.03189	-118.19858	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(20)MODULES-SOLAREWORLD SW 265 (1)INVERTER-FRONIUS PRIMO 5.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40109	11041-20000-12570	18440 W ROSCOE BLVD	91335	12	192B125   936	2102001020	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	PIN	34.21978104	-118.53506889	T.I. to existing building of outpatient therapy.  Install general/emergency lighting.  Plan check for energy only. and low voltage data permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40110	11041-20002-18592	510-516 S LANDFAIR AVE	90024	5	135B149   156	4363005046	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.04	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.0683	-118.4506	Changes to approved set of plans. Changes to breakers, relocation of exhaust fans to new panel, change to smaller elevator motor.Modification to approved plans.  See new feeders and new equipment.  Note that not all modifications have been clouded on the plan.  See approved set of plans for reference.  Plan Check Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40111	18041-10000-36997	883 N WESTERN AVE	90029	13	141B193    93	5535010024	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.0863	-118.30938	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40112	14041-20000-14897	20205 W STRATHERN ST	91306	3	189B113   447	2107017120	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.21571	-118.57323	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40113	09041-10005-17090	5557 E VALLEY BLVD BUILDING-330	90032	14	139-5A237  59	5220032003	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM			PC Approved	09/19/2011 12:00:00 AM	ADDRESS	34.07723	-118.16241	Plan review to show all previous plan checked and permited installations on one set of plans.  No new loads or equipment added since the approval of applicaiton number 09041-10004-17090.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40114	17041-10000-33822	13209 W OSBORNE ST	91331	7	201B157   534	2622015026	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Issued	09/21/2017 12:00:00 AM	ADDRESS	34.24626	-118.42074	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40115	19041-10000-17201	3785 W WILSHIRE BLVD 102 AB	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM			PC Approved	05/08/2019 12:00:00 AM	ADDRESS	34.06187	-118.30858	T-24 PLAN CHECK FOR A TI (CHANGE OF USE FROM OFFICE TO BEAUTY SALON). SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 2148 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40116	15041-20000-26740	1824 N GRAMERCY PL	90028	13	150A193   266	5544003038	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			08/17/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.10408	-118.31211	Replacing existing 400A service with new 800A service to 24 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40117	11041-10000-11195	13055 W BLUFF CREEK DR	90094	11	102B157   339	4211026013	C2(PV), R4(PV), [Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02, 2780.01	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	08/12/2011 12:00:00 AM	ADDRESS	33.97068	-118.42335	TI , TITLE 24. STARBUCKS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40118	16041-10000-03322	9114 S DENKER AVE	90047	8	094-5A195 103	6037008004	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.95403	-118.30452	PV1, ROOF MOUNTED SOLAR SYSTEM TYING INTO AN (E) SYSTEM. (11) MODULES (1) 3KW INVERTER. TOTAL SIZE IS 9KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40119	16041-10001-06446	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.04337	-118.23442	REVISIONS TO PERMITTED SET OF PLANS. FIRE PUMP FEEDER FROM THE GENERATOR  DISTRIBUTION BOARD IS REMOVED. ((((((((GENERATOR AND DISTRIBUTION BOARD  APPROVED ON SEPARATE APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40120	19041-10000-40594	27812 S WESTERN AVE	90732	15	027B193     2	7442001012	PVSP	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	9800.15	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	09/29/2020 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	33.76682	-118.31031	PC FOR ENERGY ONLY, SCOPE OF WORK IS A NEW CLUBHOUSE WITH NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 4,570 SQFT. NOTE: FULL PLAN CHECK MAY BE REQUIRED PER INSPECTOR'S REQUEST. B#16010-10000-05872	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40121	19041-20000-25756	2844 N LAMBERT PL	90068	4	154-5A191  99	5580018033	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.11893	-118.31763	Plan check for PV roof mounted and Energy Storage system, PV System size: 8.91KW  and Energy Storage System: 40.5KWh, with 27 PV Modules, 1 inverter(10KW), 3 Tesla Powerwall 2.0 13.5kWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40122	16041-10000-18507	350 S GRAND AVE #D8	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	PC FOR ENERGY. CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT. NO CHANGE IN PARKING ENTERPRISE ZONE. ONE STORY BUILDING. TOTAL AREA  554 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40123	17041-20000-29032	14418 W VENTURA BLVD	91423	4	166-5A151 175	2266001016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.15041	-118.44662	Plan check for energy only. TI/Addition to one story commercial building - retail use. T24 area: indoor - 2,393sqft; outdoor-1,150sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40124	10041-10000-07952	10250 W SANTA MONICA BLVD # 56	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	04/29/2010 12:00:00 AM		Permit Finaled	05/25/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	REMODEL EXISTING RETAIL SPACE AT THE CENTURY CITY MALLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40125	16041-20000-01200	11200 N CORBIN AVE	91326	12	210B117   384	2701040027	(Q)C1.5-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.27517	-118.5618	Plan check for energy only. TI to existing commercial building (medical).  New lighting in hallway. . Adding new lighting. Total sqft. 250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40126	12041-10000-02213	7508 W MELROSE AVE	90036	5	141B177   659	5526017027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			01/30/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	PIN	34.08337436	-118.35354775	Plan check power and energy for new Fresh & Easy market with new 2000A service. Existing building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40127	18041-30000-18910	426 S ROBERTSON BLVD	90048	5	138B169   805	4334015037	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.07142	-118.38361	FULL PLAN CHECK (POWER + ENERGY)  FOR NEW 6 STORY 37 UNIT APARTMENT BUILDING; 5 STORYA APARTMENT OVER AN ON GRADE GARAGE OVER  SUB TERRANEAN GARAGE.  1400A 120/208 V, 3PH. SERVICE. PROJECT IS LOCATED ON METHANZE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40128	13041-10000-27874	12832 W INDIANAPOLIS ST	90066	11	114B149   313	4247012009	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Expired	11/19/2015 12:00:00 AM	ADDRESS	34.01033	-118.4486	PV1, PLAN CHECK FOR ADDITIONAL 2.16KW DC PHOTOVOLTAIC SYSTEM. EXISTING PV SYSTEM INSTALLED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40129	10041-10001-01531	3335 S FIGUEROA ST SUITE-UGY-4	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	09/17/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	Delta 4 modification to approved set of plans.  Work includes adding two exhaust fans for the restroom and revising the voltage class of the yougurt machine cooling chiller from the 480 volt to the 208 volt side of the transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40130	17041-10000-39455	900 N ALAMEDA ST suite 401	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	INTERIOR ALTERATIONS ON THE 4TH FLOOR OF A DATA CENTER BUILDING, SCOPE OF WORK INCLUDES NEW PDUs AND 400A BUSWAY TAP BOXES FOR FUTURE TENANT, NO NEW LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40131	17041-10000-14669	1221 N CARY AVE	90744	15	033B209   314	7422019023	R1-1XL-O-HPOZ-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	33.78752	-118.25732	PC FOR PV SYSTEM ROOF MOUNTED. TOTAL OF 21 MODULES, SYSTEM RATED 5KW AC USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40132	16041-10000-42712	17330 W TRAMONTO DR 1-8-Bldg 1	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM	PIN	34.04114308	-118.5554747	Plan check for power and energy New appartment building 4 story 8 units (Type A) .  With 1 service 4,000A feeding all 9 buildings. Performance method is being use for Title 24. Total area: 14,623 sq ft.Note: This is 9 buildings submit  in 1 plan. 1 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40133	12041-10002-14319	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	(T)[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			03/28/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.09787	-118.31961	((((((((((TOtal of 80 smoke detectors were removed from residentail section in open balcany ( s )   3-28-14 medi zandi))))))))))))))))))))))))delta 5 changes reducing the number of FA devices that were permitted; devices have similar manufacturerJob was approved by francis on counter, plan check only.  this job should have been done at counter....NabilNEW FIRE WARNING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40134	14041-20000-06261	7651 N QUAKERTOWN AVE	91306	3	186B113    65	2106005017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.20977	-118.56997	pv1 single family dwelling. total system size 3.6 kw ac using 22 modules. using transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40135	17041-10000-30693	1677 N AMALFI DR	90272	11	132B133    27	4425022027	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.06143	-118.50025	Install (2) new AC powerwall system at 5.8 KVA each	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40136	14041-20000-21031	18200 W LASSEN ST	91325	12	201B125   103	2764021007	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Expired	09/06/2016 12:00:00 AM	ADDRESS	34.24981	-118.52959	New roof mounted PV system.  Total system size 3.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40137	14041-10000-35635	12490 W FIELDING CIR	90094	11	102B161  1250	4211034031	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			12/24/2014 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	33.9788	-118.41237	New fire alarm system for a six story apartment building with (1008) devices, (20) power supplies and (1) fire alarm panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40138	14041-20000-25606	2470 FLETCHER DR	90039	13	150A209    47	5437033009	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM			PC Approved	09/17/2014 12:00:00 AM	PIN	34.10696087	-118.25496702	REPLACE EXISTING 600AMP OVER HEAD SERVICE WITH THREE DWP METERS OVERHEAD  SERVICE TO SERVE ADDRESS 2470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40139	10041-10000-05505	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	EXPANSION OF THE BOUTIQUE IN THE MAIN HOUSE AT THE BEL AIR HOTEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40140	17041-10001-12470	620 S BROADWAY	90014	14	129A211   228	5144002020	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.04603	-118.25236	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA C ON PLANS. CHANGE TO WATER HEATER. SOME BACKGROUND CHANGES AS WELL. PERMIT TO BE ISSUED FOR ADDED WORK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40141	10041-20000-05481	6000 W SANTA MONICA BLVD	90038	13	144B189   689	5534020***	A1-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	08/11/2010 12:00:00 AM	ADDRESS	34.09049	-118.32049	service upgrade and t-24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40142	17041-10000-40647	8500 W BEVERLY BLVD suite 107	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC for power and energy for first time restuarant tenant. Installing two panels, 75kVA transformer, lights, receptacles and equipment. B#17016-10000-05331. Total area is 3562sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40143	16041-10000-16325	600 S COMMONWEALTH AVE 12TH FLOOR	90005	10	135A201   145	5077006011	C4-2	Central	Wilshire	MacArthur Park, Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.06348	-118.28545	T-24, PC FOR ENERGY ONLY. INTERIOR TENANT IMPROVEMENT TO THE 12TH FLOOR OF AN EXISTING HIGH RISE BUILDING(OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 15300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40144	15041-10001-18201	631 W JEFFERSON BLVD	90007	9	120A201    68	5123009010	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.02254	-118.28097	REVISIONS TO PERMITTED SET OF PLANS: NEW CIRCUITS FOR EV CHARGERS; NEW CIRCUITS FOR EM PHONES, NEW 1000A PULL SECTION, AND ADDED NEW TYPE OF LUMINIREALL CHANGES ARECLOUDED AS DELTA 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40145	14041-10000-35138	717 N HIGHLAND AVE	90038	5	141B185  1187	5524012***	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Expired	05/19/2017 12:00:00 AM	ADDRESS	34.0842	-118.33898	PV1, INSTALL 2.805 KW DC ROOF-MOUNTED SOLAR ARRAY ON 3-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(11) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40146	15041-10000-01531	3553 S GREENFIELD AVE	90034	5	117B161   186	4252016026	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.01973	-118.41733	install roof mounted solar array, interconnect with main panel. system size: 11.475kW. 2 inverters. inverter1:4.2kW. inverter2: 3.6kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40147	13041-20000-07785	8616 N VAN NUYS BLVD	91402	6	192B149    19	2638001038	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	34.22666	-118.44944	energy plan check retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40148	13041-10000-31899	16407 W HAMLIN ST	91406	6	180B137   507	2231003028	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.18854	-118.49054	PV1.  Install 5.25 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverters: Enphase M215.  21 modules: Canadian Solar CS6P-250P	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40149	15041-20000-22586	7609 COURAGE WAY	91405	6	186B145  1153			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.2089376	-118.46444931	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40150	19041-20000-17509	15520 W HAMNER DR pv1	90077	5	156B145   237	4378027005	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.12317	-118.465	pv1install roof mounted pv system sized 10.08KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40151	14041-20000-34403	515 S FIGUEROA ST 1150,1100	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. ADDING LIGHTING AND BRANCH CIRCUITS TO EXISTING PANNEL. PLAN CHECK FOR TITLE 24 ONLY AND EMERGENCY LIGHTING. 11TH FLOOR. TOTAL SQFT. 1942	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40152	14041-10000-19500	4121 S REDWOOD AVE	90066	11	108B153  1000	4230006018	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	33.99046	-118.43999	Plan check for power and energy. Per 2010 T24 since submitted before July 1st. BLDG#14016 30 11886 : Tenant improvement of an (e) 2 story office building. Multiply services kept existing per DWP. Inspector to verify UL listing of light fixtures.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40153	18041-10000-41197	2501 S HILL ST	90007	9	121-5A205 169	5126019010	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Issued	10/29/2018 12:00:00 AM	ADDRESS	34.02671	-118.27048	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40154	14041-10000-33773	5537 W LA MIRADA AVE	90038	13	144B193   222	5536003018	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			12/05/2014 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.09388	-118.31051	New four-story, 10-unit, type V-A  apartment building over 1 level of Type I-A basement garage.  Fully sprinklered.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40155	13041-10000-30663	711 N NEW HIGH ST	90012	1	133-5A215 110	5408022003	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.0605	-118.23856	PLAN CHECK ONLY FOR TITLE 24 PER INSPECTOR'S REQUEST.  ORIGINAL PERMIT ISSUED UNDER 13041-10000-24611.(((REPLACE NEW LIGHT FIXTURES & REPLACE WALL PLUGS & SWITCHES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40156	19041-10000-23125	1432 W 244TH ST	90710	15	039B193   269	7439018034	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	33.80315	-118.30237	PV1, ROOF MOUNTED SOLAR SYSTEM USING (22) MICROINVERTERS. TOTAL SYSTEM SIZE IS 6.82 KWDC AND 5.5KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40157	11041-20000-22290	433 S SPRING ST	90013	14	129A211    59	5149024016	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM			Corrections Issued	10/26/2011 12:00:00 AM	ADDRESS	34.04822	-118.24907	Plan check to refeed existing fire pump	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40158	19041-10000-02652	11601 W WILSHIRE BLVD STE 2170	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	PLAN CHECK FOR TITLE 24 ONLY FOR - Tenant improvement to (E) office suite 2170 (2289 SF); Scope of work to include new interior partitions, flooring/finishes, and ceiling grid.  No change in use or parking.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40159	12041-20000-19733	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.2426	-118.55846	T.I. to existing building (Chase Bank) Suite G.  Install general lighting in the office rooms and conference room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40160	13041-20000-09067	849 E 6TH ST	90013	14	126A213   228	5147016001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/22/2013 12:00:00 AM	PIN	34.04010775	-118.24128342	Plan check for energy and emergency lighting. single-story commercial. Para Los Ninos Community Wellness Center.Permit on 13041-40000-03607ELECTRICAL REMODEL AND UPGRADE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40161	16041-10000-25991	16500 W VENTURA BLVD #370	91436	5	168B137   382	2284005036	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.15743	-118.49262	TI TO MEDICAL CLINIC - DENTIST. PC FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40162	14041-20000-31517	3716 S HOPE ST	90007	9	117A203    30	5122025012	[T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.01651	-118.27956	UPGARDING EXISITING DISTRIBUTION BOARD  TO 1200AMPS AND RECONNECT ALL EXISITNG FEEDERES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40163	16041-20000-05765	17030 W DEVONSHIRE ST	91325	12	204B133   214	2694001031	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.25725	-118.50364	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,400 sq. ft.Note: Building application has been created under 15016-20000-28221	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40164	19041-20001-29368	11957 N LOUISE AVE pv1	91344	12	216B129   212	2606026033	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM			Reviewed by Supervisor	08/06/2019 12:00:00 AM	ADDRESS	34.28854	-118.51244	expeditepv1install ground mount pv system sized 15.2KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40165	15041-10003-40809	5231 N MOUNT HELENA AVE	90041	14	163-5A227 163	5691006039	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM			PC Approved	03/10/2016 12:00:00 AM	ADDRESS	34.1426	-118.19593	Changes to approvd set: Relocate DC disconnect to the North side of the house. Fee zero dollar per California Senate Bill 1222.   Permit under 15041-10000-40809<<PV1, Install 14.05 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (2)INVERTER: SMA SB7700TL-US-22 & SB5000TL-US-22. (43) modules SUNPOWER SPR327NE-WHT-D>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40166	10041-10000-10204	3434 S GRAND AVE Room 190	90007	9	118-5A203 116	5122030020	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	05/28/2010 12:00:00 AM		Permit Finaled	06/17/2010 12:00:00 AM	ADDRESS	34.01912	-118.27658	TI on the 1st floor in Room #190, Storage area. Plan Check is for T-24 Energy Calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40167	14041-20001-06670	6562 N ENSIGN AVE PV 1	91606	2	180B173   523	2336003023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Issued	04/28/2014 12:00:00 AM	ADDRESS	34.1901	-118.37164	Modifications to approved set. (3) additional modules and microinverters.  System size increased to 3.24 kW.  (((PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 2.59KWAC. ZONING ALREADY CLEARED ON APPLICATION#: 12041-20000-30683)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40168	18041-10001-42602	7722 W MELROSE AVE	90046	5	141B177   626	5527022027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Info Complete	11/14/2018 12:00:00 AM	ADDRESS	34.08355	-118.35817	SUPPLEMENTAL TO CHANGE OF USE FOR RETAIL SPACE APPROXIMATLY 4000SQFT TITLE 24 ONLY WITH 100 AMP NEW PANEL SCOPE OF WORK INCLUDES LIGHTING AND HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40169	15041-20000-09703	6250 N TOPANGA CANYON BLVD #1540 B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for power and Title-24 (energy).  Total area = 4,904 sq. ft. (indoor) and 90 sq. ft. (outdoor)T.I. to retail space.  First time tenant.  Three new panels and one 75 kVA transformer.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40170	19041-10000-51499	304 S BROADWAY UNIT 540	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	34.05076	-118.248	ENERGY PLAN CHECK ONLY FOR NON-STRUCTURAL T.I. TO (E) OFFICE . NEW PARTITON WALLS, NEW CEILING, LIGHTING AND FINISHES. AREA OF SCOPE (2560)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40171	19041-20000-30742	7203 N HYANNIS DR	91307	12	183B093    82	2027012015	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.2009	-118.64141	PV1.  Install 10.89 kW DC / 9.8 kW AC roof mounted grid tied PV system with 9.8 kWh DC-coupled energy storage system.  (33) modules with 6 and 3.8 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40172	17041-10000-15238	727 E 22ND ST	90011	9	121-5A209 358	5131012024	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.0248	-118.25869	Rooftop solar installation on SFD, system is 2.64kW DC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40173	15041-20005-24184	8842 W FOOTHILL BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.26086	-118.32514	"04-22-2019 Changes to an approved set of plans, changes include addition of emergency lights in the elevator lobby area, loading dock and relocate panel ""LA"" and ""HA"" to be in the corridor, all changes has been clouded. Plan check only, permit covered under master application."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40174	19041-10000-21611	10732 N LAUREL CANYON BLVD	91331	7	207B153   176	2616010907	OS-1XL-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.26539	-118.43888	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40175	15041-10000-43972	6600 W SUNSET BLVD 2ND FL TO-4TH FL	90028	13	147A185    65	5547024032	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.09782	-118.33334	ALTERATIONS TO EXISTING 4-STORIES BUILDING- 2ND FL  AND 3RD FL  AND MEZZANINE LEVEL CHANGED TO OFFICES; 2 NEW PANEL BOARDS WITH NEW CKTSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40176	14041-10001-07440	100 S ROBERTSON BLVD	90048	5	138B169   373	4334005002	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM			PC Approved	03/09/2015 12:00:00 AM	ADDRESS	34.0751	-118.38359	THIS IS A ONE STORY RETAIL TITLE 24 AND EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40177	10041-10000-03685	4061 W WASHINGTON BLVD	90019	10	126B185   939	5072013003	C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	Public Safety Only			03/02/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	04/21/2010 12:00:00 AM	PIN	34.04021364	-118.32763128	INSTALL A NEW FIRE LIFE SAFETY SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40178	11041-10000-05310	2815 W JEFFERSON BLVD	90018	10	120B189   611	5051036043	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.02574	-118.32651	new laundry in existing building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40179	16041-30000-29102	801 S FIGUEROA ST 9th FL-corridor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for title 24 only in existing space T.I. corridor. Total area: 1,785 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40180	11041-10000-11275	850 N CAHUENGA BLVD	90038	4	144B185  1242	5533029001	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	10/28/2011 12:00:00 AM	ADDRESS	34.08685	-118.32863	T.I.  for a 2 story Boys & Girls club.  Building is supplied with 2 existing services.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40181	18041-20001-01636	2759 N HOLLYVIEW CT	90068	4	153B181   590	5549031***	(T)(Q)RD3-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM			PC in Progress	01/20/2018 12:00:00 AM	ADDRESS	34.11869	-118.34249	Expedited plan check fee. PV1.  Install 7.6 kW AC/ 10.15 kW DC roof mounted grid tied PV system.  (29) modules with power optimizers/string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40182	15041-20000-05048	1669 N SAN ONOFRE DR	90272	11	135B133   221	4425002034	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2015 12:00:00 AM			PC Approved	04/06/2015 12:00:00 AM	ADDRESS	34.06225	-118.50273	NEW 600 AMP SERVICE FOR REMODEL TO SFD.  PLAN CHECK FOR POWER. permit issued under building permit. no fees due under this application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40183	15041-20000-19724	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	PV2. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM SIZE: 700 KW.SYSTEM A: 378KW DC1221 MODULES TRINA SOLAR & 15 INVERTERS SOLECTRIA PVI-20TLSYSTEM B: 320 KW DC1034 MODULES TRINA SOLAR & 12 INVERTERS SOLECTRIA PVI-20TLNote: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40184	14041-20000-01559	11990 W VENTURA BLVD	91604	2	162B165   132	2369015016	(Q)C2-1VL, (Q)P-1VL, C2-1VL, P-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.14351	-118.39333	PC FOR T24 ENERGY ONLY. RESTAURANT WITH NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40185	17041-10000-12237	12100 W WILSHIRE BLVD STE 1090	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.0438	-118.46755	PC FOR T24 ENERGY ONLY. OFFICE TI. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40186	19041-10000-42260	21730 W VENTURA BLVD	91364	3	171B105    41	2168024064	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	02/13/2020 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.16815	-118.60173	PC FOR POWER AND ENERGY.(TI FOR MEDICAL OFFICE). SCOPE INCLUDES RELOCATING AN EXISTING 225A PANEL AND NEW CIRCUITS AND LIGHTING. TOTAL AFFECTED AREA IS 1304 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40187	16041-20000-23298	633 W 5TH ST #6700	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check Title 24 in existing high-rise office space Suite # 6700. Total area 3,812 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40188	19041-20001-31751	4874 W AMBROSE AVE	90027	4	150B197   332	5589019018	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.10892	-118.29585	EXPEDITED PER CUSTOMER REQUEST.PV1. INSTALL (39) ROOFMOUNTED MODULES WITH POWER OPTIMIZERS AND (3) WALL MOUNTED TESLA ENERGY STORAGE SYSTEMS. SYSTEM SIZE 12.28 KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40189	16041-20000-17392	10989 W ROCHESTER AVE	90024	10			R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			Reviewed by Supervisor	06/10/2016 12:00:00 AM	ADDRESS	34.05561	-118.44536	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 48KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40190	18041-10000-38406	1119 N MCCADDEN PL	90038	4	144B185  1373	4254008039	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.09138	-118.33766	NEW 600AMP TEMPORARY SERVICE TYING TO AN EXISTING DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40191	17041-20001-43714	6461 N PENFIELD AVE	91367	3	180B113   685	2134038013	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			PC Approved	12/14/2017 12:00:00 AM	ADDRESS	34.18827	-118.56925	expeditepv1instal roof mounted pv system sized 10kw interconneced with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40192	18041-10000-38321	5343 W IMPERIAL HWY #850	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93128	-118.37337	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40193	16041-10000-26078	6360 W 3RD ST	90036	2	162B165    17	2367016010	C2-1L-RIO, P-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.07122	-118.36074	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (CVS PHARMACY). SCOPE INCLUDES NEW LIGHTS FOR BATHROOM/CORRIDOR SPACES. TOTAL AFFECTED AREA IS 155 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40194	19041-10000-15393	782 E 12TH ST	90021	14	123A211    88	5132012061	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.0323	-118.25096	Remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40195	19041-20000-41784	1919 S PONTIUS AVE	90025	5	126B153   332	4323025014	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	02/11/2020 12:00:00 AM		Issued	02/11/2020 12:00:00 AM	ADDRESS	34.04362	-118.44177	PV3 PLAN CHECK FOR NEW ROOFMOUNTED PV SYSTEM. SYSTEM SIZE IS 23.1 KW DC/20 KW AC CEC. SCOPE OF WORK CONSISTS OF (70) PV MODULES WITH OPTIMIZERS, (2) 9 KW CENTRAL INVERTERS, AND A 125A PV SUB PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40196	19041-10000-18367	953 N SYCAMORE AVE STE C	90038	4	144B181   641	5531015010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	PC FOR T24 FOR A TI. SCOPE OF WORK INCLUDES NEW POWER AND LIGHTING, WILL USE NEW AND EXISITNG ELECTRICAL EQUIPMENT((TI WORK ON APPROX 2,447 SF OF THE TOTAL FLOOR AREA.  NEW WALL, AND FINISHES.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40197	19041-10000-08540	1564 N CAHUENGA BLVD	90028	13	148-5A187 322	5546012400	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.09957	-118.32935	pc t-24 for resturant TI.  with a area of  3671 sqft. Scope includes new lightingand equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40198	19041-10000-19806	717 N TIGERTAIL ROAD	90049	11	138B141   367	4494012015	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2019 12:00:00 AM			Reviewed by Supervisor	06/04/2019 12:00:00 AM	ADDRESS	34.07315	-118.48253	2-story addition of 10,000 Sqr ft to (e) 3-story SFD with a new 1,200 Amp Service.Buiding Permit: 17014-10000-04095 revise the floor plan layout under permit no. 11014-10000-01115 and 14014-10000-00945, 17014-10000-04095	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40199	16041-10001-01115	5126 N DAHLIA DR	90041	14	163-5A227 359	5669012015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM			PC Approved	01/25/2016 12:00:00 AM	ADDRESS	34.14037	-118.19959	Expedite per applicant***PV1, rooftop mounted 15.2 kW Ac system interconnect with 200 MSA, 46 modules, (2) Fronius Primo 7.6, (2) load centers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40200	13041-10000-14309	2151 S GUTHRIE DR	90034	5	126B165   307	4309016011	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.04335	-118.39378	PV1.  Install new 5.145 kW DC roof-mounted solar array, interconnect with main service panel.  {21 modules: Trina Solar TSM-245PC05/PA05.18} {Transformerless inverter: SolarEdge SE5000A-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40201	19041-10000-23552	9200 S SEPULVEDA BLVD	90045	11	093B165    69	4124001006	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Issued	06/20/2019 12:00:00 AM	ADDRESS	33.95336	-118.39596	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40202	18041-10000-45017	529-539 N AVALON BLVD	90744	15	030B205   921	7418005013	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	03/13/2020 12:00:00 AM		Permit Closed	03/20/2020 12:00:00 AM	ADDRESS	33.77651	-118.26247	Energy plan check for a CARPENTRY/UPHOLSTERY SHOP INSIDE EXISTING 2-STORY building. Scope includes new lighting and equipment with a total area of 7,361 SQ FT.Note. Portion of electrical permit fee is paid under 18041-70000-39787	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40203	18041-10000-11828	550 S HOPE ST STE 200	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	PLAN CHECK FOR TITLE 24 ONLY FOR TI BUILD OUT ON 2ND NON LOAD BEARING PARTITIONS, NEW FLOOR/WALL/CEILING FINISHES  4036 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40204	16041-10000-41580	5902-5906 N FIGUEROA ST	90042	1	151-5A229 148	5492015010	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.11045	-118.19069	T-24, PC FOR ENERGY ONLY. CHANGE OF USE OF ONE TENANT SPACE FROM REGULAR RETAIL TO MARKET WITH TI WORK. CHANGE OF USE OF ONE TENANT SPACE FROM RETAIL TO RESTAURANT AND COMBINE WITH ADJACENT RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR MARKET AND RESTUARANT SPACES. TOTAL AFFECTED AREA IS 1080 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40205	13041-10001-28627	5840 W CENTINELA AVE	90045	11	102B169    68	4103005033	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Info Complete	01/23/2014 12:00:00 AM	ADDRESS	33.97633	-118.38267	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. T24 ENERGY AND CHANGES IN LOAD ON PANEL TP4A AND TP1. S-M. NEW CIRCUITS AND AND NEW LIGHTING ON EXISTING CIRCUITS.ORIGINAL APP # 13041-10000-28627	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40206	15041-20000-39588	6060 W WILSHIRE BLVD	90036	4	135B177   526	5086009014	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.06273	-118.36103	TI to existing commerical building. Petersen auto museum. Plan check for power and energy.  1st floor restaurant and kitchen. 4th floor catering kitchen. Adding new lighting including emergency. Total sqft. 3608	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40207	19041-10000-06345	1552 S HI POINT ST 1-9	90035	10	129B173   971	5068018012	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			02/21/2019 12:00:00 AM			Reviewed by Supervisor	02/27/2019 12:00:00 AM	ADDRESS	34.04849	-118.36942	INTERIOR REMODEL OF EXISTING 9 UNIT APARTMENT. SERVICE UPGRADE TO 600 AMP, REPLACE ALL UNIT PANELS (9) AND ADD WASHER, DRYER & HVAC TO EACH UNIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40208	14041-20000-00726	8416 N TYRONE AVE	91402	6	192B153   452	2638024021	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.22388	-118.44419	New rooftop mounted PV system for an existing single family dwelling.  System is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40209	16041-10000-38982	1250 S WESTMORELAND AVE	90006	1	129B197   979	5076018023	R4-1XL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			11/09/2016 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.0479	-118.2889	PLAN CHECK FOR POWER AND TITLE 24.  NEW 7-STORY 93-UNIT SENIOR AFFORDABLE BUILDING.  SYSTEM INCLUDES NEW 3,000 AMP 208/120 VOLT SERVICE, EMERGENCY GENERATOR, AND FIRE PUMP.  TOTAL COMMON AREA = 52,040 SQ. FT.(REF B# 16010-10000-05028)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40210	13041-10000-18034	10639 N GLENOAKS BLVD	91331	7	207B165   213	2536015221	[T][Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.26264	-118.40007	PC for power only. New meter section 800A 'MS'. and 3 new panels 'AH', 'BH', and 'HP'. everything else existing (AC-1/2 and panels  AL and BL) and loads as well. not a hazardous location per applicant. only sells autoparts. 2 weeks from 7/9/2013. customer agrees to proide an official fault current report - either on computer or henry abrari within 2 weeks. should this information not be provided, then approval will be revoked.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40211	19041-20001-09551	7304 N JORDAN AVE	91303	3	186B105   848	2111013022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	08/21/2019 12:00:00 AM	ADDRESS	34.20311	-118.60273	INSTALLATION OF A 20.13KW DC/17.11KW AC CEC/22.8 KW AC ROOFTOP MOUNTED PV SYSTEM ON A EXISTING COMMERCIAL LOW RISE. SCOPE OF WORK INCLUDES (61) PANASONIC 330W PV MODULES WITH P400 OPTIMIZERS, (3) 7.6KW SOLAR EDGE INVERTERS, AND A 125 PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40212	12041-20000-04489	10290 W CRESTA DR	90064	5	126B161   157	4308011007	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Expired	04/07/2014 12:00:00 AM	ADDRESS	34.04128	-118.40672	Roof mouted PV system with 3.29 KWdc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40213	15041-20001-18184			12	216B109   298	2701083020		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	PIN	34.29206464	-118.58179088	11/23/15: Changes to an approved set, T-24 only. MSB from 200A to 400APermit under 15041-20000-18184RECREATION BUILDING INCL LAUNGE/ POOL BATH ROOMS/ EQUIPMENT ROOMS/ TRELLIS AND ENTRY TOWERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40214	19041-10000-28155	1541 N WILCOX AVE	90028	13	147A187    22	5547017003	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	10/13/2021 12:00:00 AM	ADDRESS	34.09913	-118.33128	PC FOR NEW FIRE ALARM SYSTEM, 3 LEVELS SUBTERRANEAN AND 11 LEVELS ABOVE GRADE. 1 FACP, 6 CONTROL PANEL, 916 DEVICES AND 508 COMMUNICATION DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40215	16041-10000-21830	7051 W ESTEPA DR	91042	7	198B201    25	2564013006	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.24232	-118.2847	PC FOR A SOLAR GROUND MOUNTED SYSTEM. TOTAL SYSTEM SIZE IS 11.16KWdc / 8.640KWac(36)MODULES- LG310(36)MICROINVERTER-M250	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40216	13041-10000-05362	4602 N SALOMA AVE	91403	2	168A149   153	2264020010	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.15413	-118.45836	3.43 KW SOLAR INSTALLATION {14 MODULES: REC 245 PE BLK} {MICROINVERTERS: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40217	18041-20000-14916	6922 W HOLLYWOOD BLVD 10th Floor	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	Plan check for energy only in existing highrise building 10th floor T.I. office. Total area: 12,745 sq ft.B#18016-10000-10560	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40218	19041-20000-07098	15815 W MONTE ST #105-#106	91342	7	225B141  1525	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Issued	04/16/2019 12:00:00 AM	ADDRESS	34.31113	-118.47563	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from office/storage to pharmeceutical manufacturing/tenant improvement. Total lighting area = 12,083 sq. ft.Note: Building permit has been issued under 18016-20000-05898	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40219	13041-10000-27739	210 W 7TH ST	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.04461	-118.25275	INSTALLING 120/208 300KVA TRANSFORMER TO PROVIDE POWER WITH EMON DEMON SUBMETER IN A COMMERCIAL BUILDING (CVS). NEW FEEDER , NEW FUSIBLE SWITCH, AND GRND IS ALSO PART OF THE SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40220	19041-20000-19438	23029 W DOLOROSA ST pv1	91367	3	174B097   698	2042003038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.17062	-118.62873	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD AND EXISTING DETACHED GARAGE. SYSTEM SIZE IS 12.24 KW DC/2.059KW AC CEC/10.71KW AC. SCOPE OF WORK INCLUDES (34) SUNPOWER PV MODULES WITH INTEGRATED MICRO INVERTERS, AND (2) 100A PANELS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40221	16041-20001-26777	7172 W HAWTHORN AVE	90046	4	147B181   449	5548011061	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.09956	-118.34638	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on an Apartment building. Interconnect with a 400A MSP. Derating main breaker from 400A to 250A. 40kW ungrounded system [4*10kW]. (176) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40222	12041-10001-21410	10900 W WILSHIRE BLVD #100	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM			PC Approved	12/03/2012 12:00:00 AM	ADDRESS	34.05848	-118.44419	Revisions to permitted set of plans-all changes are clouded on the plans.Most of the changes are to the Lighting system and includes reuction of the Lighting wattage.TENANT IMPROVEMENT: change an existing bank to a new citi bank; customer requested full plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40223	17041-20001-20128	7809 N FAUST AVE	91304	12	189B097   888	2013028021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM			PC Approved	06/25/2017 12:00:00 AM	ADDRESS	34.21222	-118.62065	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.10.4kW ungrounded system. (28) 300W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40224	13041-10000-33080	22538 W VANOWEN ST	91307	12	180B097    28	2038027008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.19356	-118.61806	PV1.  Install 4.75 kW roof-mounted PV system, interconnect with main service panel.  19 modules: Trina Solar TSM-250PA05.18.  Transformerless inverter: SolarEdge SE5000A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40225	15041-10000-26195	13420 W SATICOY ST	91605	2	186B157   183	2303024011	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM			PC Approved	08/12/2015 12:00:00 AM	ADDRESS	34.20861	-118.42526	PLAN CHECK FOR ENERGY ONLY FOR PARKING LOT LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40226	12041-20000-26756	22366 W PHILIPRIMM ST	91367	3	174B101   207	2146023027	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	02/12/2013 12:00:00 AM	ADDRESS	34.17266	-118.61433	Three circuit enphase system on roof of single family dwelling with 125 ampere collector panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40227	15041-20001-31729	11776 N ENCINO AVE	91344	12	213B129    38	2607012011	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM			PC Approved	10/05/2015 12:00:00 AM	ADDRESS	34.28417	-118.51526	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (57) modules, (1) load center, and (2) combiner boxes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40228	16041-20000-25770	12323 W VENTURA BLVD	91604	2	162B165   165	2367018009	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.14316	-118.40168	TI TO AN EXISTINGCOMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1801.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40229	13041-20000-00644	17540 W MAYERLING ST	91344	12	213B129    94	2607010018	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Expired	03/04/2015 12:00:00 AM	ADDRESS	34.28298	-118.51615	New 9.8kw PV System, rooftop mounted, for an exisiting single family dwelling.  Micro-inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40230	18041-10001-07865	707 W WILSHIRE BLVD 4450	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	T-24 ENERGY ONLY IN SUITE #4450 ON THE 44TH FLOOR.ELECTRICAL PERMIT WAS ISSUED UNDER 18041-90000-07865	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40231	18041-20000-47475	2812 W TEMPLE ST	90026	13	138A203   118	5156016002	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			12/14/2018 12:00:00 AM	04/07/2021 12:00:00 AM		Permit Finaled	11/03/2022 12:00:00 AM	ADDRESS	34.07369	-118.27811	new apartment building 42 units mix use.  1600 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40232	15041-20000-27307	8500 N BALBOA BLVD	91343	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	PIN	34.22443327	-118.49947932	Title 24 plan check only.  Total area = 145 sq. ft.  Installation of new lights and outlets in existing sound room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40233	18041-10000-40602	6238 W SANTA MONICA BLVD	90038	13	144B189   699	5534022031	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.09056	-118.32573	CHANGE OF USE FROM RETAIL TO RESTAURANT. NEW KITCHEN EQUIPMENT. NEW COMMERCIAL KITCHEN. SCOPE OF WORK INCLUDES NEW PANELS, LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1607	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40234	15041-10000-36375	10420 N SEPULVEDA BLVD BLDG 2	91345	7	204B145    23	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.25976	-118.46706	NEW TWO FLOOR MULTI USE BUILDING. CORE AND SHELL ONLY.  PLAN CHECK FOR POWER AND ENERGY.BUILDING APLLICATION# 15010-10000-03863	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40235	14041-20000-30531	706-720 N CAHUENGA BLVD	90038	13	141B185   537	5533032014	C4-1XL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.08371	-118.32861	Plan check for power and energy. Commercial building. Previously industrial, now an office. New 1600A service and equipment, install in electrical room. Core and shell, incl. TI to existing restroom. 1,582sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40236	12041-10000-25511	10840 W WILSHIRE BLVD	90024	5	132B153   401	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.05924	-118.44131	B OCCUPANCY, EMERGENCY EXIT AND LIGHTING REQUIRED. PROPOSED ADDITION AND REMODEL TO PORTION OF EXISTING BLDG- CONVERTING A PORTION OF EXISTING THEATER TO A RESTAURANT AND BAR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40237	15041-20000-16317	936 S OLIVE ST UNIT 249	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #16 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40238	12041-20000-14546	2029 CENTURY PARK EAST 2070N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM			PC Approved	06/22/2012 12:00:00 AM	PIN	34.05957272	-118.4137405	T24 and emergency lighting plan check for suite 2070N.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40239	11041-10000-24414	12659 W ALBERS ST	91607	5	174B161   584	2346008006	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2011 12:00:00 AM	01/05/2012 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.17045	-118.40914	INSTALL A NEW 8KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40240	14041-10001-04468	16800 W LIGGETT ST	91343	12	198B137   466	2687009012	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.23995	-118.49843	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 8.25 KW DC ROOF -MOUNTED SOLAR ARRAY ON A HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTER:  SOLAREDGE  SE5000A-US(240)(33) MODULES; RENESOLA JC250M-24/BB.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40241	19041-10000-32658	3259 W 8TH ST	90005	10	132B197   452	5094005012	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.04	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.05785	-118.2993	Energy plan check for a CHANGE OF USE T.I. FROM (E) GROCERY MARKET TO TAKE OUT ICE CREAM SHOP. Scope includes new lighting and equipment with a total lighting area of 1,727-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40242	15041-10000-27706	11700 N CORBIN AVE	91326	12	216B113     1	2701002068		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Issued	09/21/2015 12:00:00 AM	ADDRESS	34.28162	-118.57177	PLAN CHECK FOR OUTDOOR LIGHTING FOR ENTIRE TRACT HOMES, TRACT #50509-01.  TOTAL SQUARE FOOTAGE 238,416.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40243	15041-10000-24266	1375 E 6TH ST	90013	14, 3	186B105   821	2112024012	M3-1-RIO, R3-1	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Central City North	Canoga Park, Historic Cultural		1345.21, 2060.31	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Info Complete	07/29/2015 12:00:00 AM	ADDRESS	34.03838	-118.23372	TI TO AN EXISTING COMMERCIAL BLDG ADDING NEW LIGTHING NEW CONTROLS TO EXISTING PANELS. PC FOR ENERGY AND EMERGENCY LIGHTING ONLY. TOTAL SQ FT 3040L.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40244	17041-20000-43070	20700 W SESNON BLVD	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	07/28/2020 12:00:00 AM	ADDRESS	34.29545	-118.58467	pv1install roof mounted pv system sized 5.7kw interconnected with msp.new development, general site address to be updated accordingly.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40245	14041-10000-33087	10921 W WILSHIRE BLVD 5th Floor	90024	5	132B153   344	4363023032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.05881	-118.44477	PLAN CHECK FOR POWER AND ENERGY FOR DENTAL OFFICE ON THE 5TH FLOOR OF A HIGHRISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40246	14041-10000-21051	859 N HIGHLAND AVE	90038	5	144B185  1229	5524003022	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.08688	-118.33877	PC FOR POWER AND ENERGY. CHANGE OF USE FROM SERVICE STATION TO RESTAURANT; NEW STARBUCKS COFFEE IN HISTORIC GILMORE GAS STATION SHELL;  TOTAL AREA 827 SQ FT.B#14016-10000-14394.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40247	16041-30000-35871	500 S SANTA FE AVE	90013	14	126A217   221	5164004002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.04107	-118.23124	Installation of fire alarm system in new 4 story commercial office building.  Total system size = 186 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40248	12041-20000-11570	11507 W OXNARD ST	91606	2	177B169   797	2338004001	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Info Complete	10/10/2012 12:00:00 AM	ADDRESS	34.1796	-118.38271	New mixed use commerical building with medical offices, offices, and retail spaces.  Check for interior and exterio energy and electrical.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40249	16041-10000-38084	10250 W SANTA MONICA BLVD # 1813	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Kendra Scott"" Ste. 1813.  Install new panels and its circuits, lights and receptacles. Total effected area: 897 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40250	17041-10001-01250	833 E IMPERIAL HWY	90059	15	087A209   366	6072013022	RD2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM			PC Approved	04/03/2017 12:00:00 AM	ADDRESS	33.93118	-118.25989	Expedited rses plan check per applicant request. <<<<NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE = 12.2KVA INCLUDING 2 CENTRAL INVERTERS(SOLIVIA - SOLIVIA 5.2TL & 7.6TL), WITH 50 MODULES(LDK 280P-24).>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40251	14041-20000-20114	3300 W BERKELEY AVE	90026	13	144A205   207	5425002001	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.0894	-118.27341	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.4KW INTERCONNECTED WITH MSP.(25) SOLAR WORLD SW250 MODULES(25) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40252	11041-10000-14531	1307 S MATEO ST	90021	14	121-5A217  80	5166022034	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	07/14/2011 12:00:00 AM	ADDRESS	34.0285	-118.23235	PER APPLICANT, T-24 FOR CHANGE OF 3 LIGHTS IN AN EXISTING FOOD PACKING PLANT.  PLAN CHECK IS FOR ENERGY ONLY WITH EMERGENCY CIRCUIT ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40253	09041-10003-21978	8500 W BEVERLY BLVD # 735	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM			PC Approved	07/26/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	DELTA 3 REVISIONS TO PERMITTE DSET OF PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40254	12041-10000-15924	3000 RUSTIC CANYON ROAD		11	144B125     7	4432005029	A1-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	9800.19	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	PIN	34.09096078	-118.52762793	AT A BOYS' CAMPSITE, REMODELING THE HANDICRAFT CENTER AND THE TRADING POST CABIN-ALL COMMON AREAS  AND SEPARATE FROM THE SLEEPING CABINSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40255	14041-10000-07013	2753 W WAVERLY DR BLDG.-#5	90039	4	151-5A207 233	5438025012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Apartment			03/26/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.10855	-118.26334	Plan check for energy and power. Building #5, 6 unit townhouses. Total area sq ft.The appliction isn't complete.Please review the plan.Description from building permit (13010-10000-00130):{{{PHASE I:  (BUILDING #5 - 6 UNITS). CONSTRUCT NEW 3-STORY WITH ROOF DECK TOWNHOUSE WITH ATTACHED TWO CAR GARAGE FOR EACH UNIT AT FIRST LEVEL.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40256	14041-20000-02902	8546 N BOTHWELL ROAD	91324	12	192B117   123	2783016008	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.22593	-118.56097	PV1 SINGEL FAMILY DWELLING TOTAL SYSTEM SIE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40257	13041-10000-23159	3202 W 78TH PL	90043	8	099B185   334	4012009001	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	33.968	-118.32887	PV1 8KWdc 240V XFMR(-)INV. 1STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V7.5][( 33) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40258	16041-10000-38130	7407 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM	ADDRESS	33.94205	-118.42493	PC FOR 250KW GEN SET SUPPLYING EXISTING DISTRIBUTION BOARDS. PROJECT LOCATED IN METHANE ZONE. PLAN CHECK FOR HAZARDOUS AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40259	12041-10000-28665	624 S GRAND AVE 2600	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM			PC Approved	12/10/2012 12:00:00 AM	PIN	34.04778206	-118.25563275	T24 FOR EXISTING COMMERCIAL. 25TH FLOOR.812SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40260	18041-10000-26130	318 S LINCOLN BLVD 225	90291	11	111B145   642	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			Corrections Issued	07/12/2018 12:00:00 AM	ADDRESS	34.00111	-118.46697	TI IN AN EXISTING OFFICE AREA ON 2ND FLOORT-24 ENERGY ONLY.BLDG PERMIT # __________________	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40261	14041-20000-33383	649 W 34TH ST SUITE 106-108	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM			PC Info Complete	12/02/2014 12:00:00 AM	PIN	34.02214675	-118.28186522	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING LIGHTING AND RECEPTACLES TO OFFICES.  TOTAL SQUARE FOOTAGE 2799.  PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ONLY.  ADDING CIRCUITS TO EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40262	13041-20000-29492	17831 W FULLERFARM ST	91325	12	204B129   357	2734003008	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.25414	-118.52285	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 20 MODULES. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 4 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40263	13041-10000-20412	12746 W JEFFERSON BLVD #1160	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	PLAN POWER AND ENERGY FOR FIRST TIME TENANT. CHASE BANK. SUITE #1160 IN BUILDING #1. POWER SUPPLYING (PANELS, TRANSFORMER) TENANT AND RESTROOM PLAN CHECK UNDER #13041-10000-26831.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40264	15041-10000-00887	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"Plan check for T-24 only. Install (3) 3' X 3'-8"" S/F illum. wall signs on (E) parking structure (9-1)Refference building permit: 14048-10000-01691 Replace existing fluorescent light sign to LED. Retrofit existing fluorescent light sign to LED sign with new face panel. Added new LED sign connect to existing power circuit."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40265	15041-20000-07287	12811 W VICTORY BLVD	91606	2	180B161  1049	2325032004	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	ADDRESS	34.18685	-118.41216	Title 24 plan check only.  Total area = 3,139 sq. ft.T.I. to existing commercial restaraunt space.  2008 Title-24 standards used - building application submitted before July 1st 2014.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40266	15041-20000-30434	1635 N VINE ST	90028	13	148-5A187 206	5546009038	C4-2D, C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.10082	-118.32687	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 1,740 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40267	10041-10000-19955	5930 W FRANKLIN AVE	90028	4	150A191   192	5586027012	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.10506	-118.31873	This is six story with roof fire alarm panel repacement  phase one, all green devices to be replaced with same type compatible.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40268	11041-10000-19146	11035 W MAGNOLIA BLVD	91601	4	171B173   540	2350018059	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	01/10/2012 12:00:00 AM	ADDRESS	34.1651	-118.37135	REPLACE OLD FIRE ALARM CONTROL PANEL AND ANNNUNCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40269	19041-10000-08672	3191 W 4TH ST	90020	13	135B197   470	5501024900	OS-1XL	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.06723	-118.28951	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40270	14041-10001-14510	1075 N VILLA GROVE DR	90272	11	129B129   356	4409006014	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.04995	-118.51364	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 7.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40271	17041-10000-37632	2121 S AVENUE OF THE STARS 33RD FLR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	PC for T24 only for new lights in high rise. Total area is 13718sqft. Installing new panel and new circuits.Building 17016-10000-26580. Load is under 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40272	07041-10001-11169	4550 W PICO BLVD	90019	10	129B185  1008	5083033004	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.04842	-118.33486	Delta 1 revisions to permitted set of plans))))))))))New 2-level retail building and connected three level parking stucture with retail on top level. Three 3000 A services.  Core and shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40273	19041-10000-44584	14006 W RIVERSIDE DR 21	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Issued	11/25/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLAN CHECK FOR TITLE 24 ONLY - TOTAL AFFECTED AREA = 1866SF	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40274	18041-10000-02140	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	PC for power and energy for LAX terminal 4. Installing four new panels, transformers, lights, receptacles and equipment for baggage, service and office areas. Total area is 17975sqft. //NOTE TO PLAN CHECKER, 98 MORE CIRCUITS WHERE ADDED TO FEES DUE TO PRECUT CHECK. FINAL FEES SHALL BE LOWERED BY 98 CIRCUITS TO REFLECT CORRECT NUMBER OF CIRCUITS.//B# 17016-10000-33719	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40275	19041-10000-51231	811 N BRIDEWELL ST	90042	14	154-5A235 211	5493037003	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.11729	-118.17029	(E-PLAN) NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SERVICE OF 225 AMPS. INSTALLATION INCLUDES 1 ENERGY STORAGE SYSTEM, 20 MODULES (PANASONIC 330W), 20 MICROINVERTERS (IQ7X-96-2-US), AND 1 PANEL OF 125 AMPS.SYSTEM SIZE: 6.6 KW DC; 6.3 KW AC*NOTE: PANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40276	14041-10000-00013	1165 S CROCKER ST	90021	14	123A211    15	5132011240	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.03336	-118.25175	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 288 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40277	12041-20000-19608	5249 N LANKERSHIM BLVD	91601	2	171B173   417	2350017033	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM			PC Approved	08/23/2012 12:00:00 AM	ADDRESS	34.1662	-118.37562	Plan check for energy and emergency lighting. 2030 sqft. Occpant load is less than 100. cocktail lounge.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40278	18041-30000-23264	12555 W VANOWEN ST	91605	2	183B161   924	2324029011	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Apartment			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.19409	-118.40698	Plan check for a fire alarm system located in a new 3-story 12-unit apartment building. Scope include (1) fire alarm system, (1) power supplies and (74) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40279	15041-10000-24926	5121 N SAN FERNANDO ROAD WEST bldg 34	90039	13	165B205   119	5593011043	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Issued	08/05/2015 12:00:00 AM	ADDRESS	34.1457	-118.27194	FIRE ALARM SYSTEM REPLACEMENT. Hazardous location. Buildings 24 (H-3), 25 (mixed - H-2, H-3, F-2, B), 33 (F), and 34 (H-2, F, B).This permit covers building 34. Fees are under inspection (3 of 4). See 150411000018030 for main plan check application.	N	N	Express Permit	06/10/2024 12:00:00 AM
40280	10041-10000-00174	2001 N BENEDICT CANYON DR	90210	5	150B153   552	4383013017	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM			PC Approved	01/13/2010 12:00:00 AM	ADDRESS	34.10707	-118.43647	Plan check for electrical system to provide service to the contruction phase for at future residence, and may supply portions of the future residence.  This may or may not be a temporary service.  Complete plan check at request of the instpector.  Existing permit on application # 09041-30000-21529.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40281	15041-20000-08527	6320 N TOPANGA CANYON BLVD G-1680	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and energy. Project scope is a first time tenant for one of the tenant spaces at the Topanga Canyon Westfield Mall. Project work included (1) 200-amp service, (2) 200-amp rated panels, and associated loads. Total lighting area = 3,934 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40282	11041-10001-07834	600 W 7TH ST	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM			PC Approved	12/01/2011 12:00:00 AM	ADDRESS	34.04728	-118.25685	CHANGE OF USE FROM RETAIL TO A RESTAURANT,  HIGH RISE, EMERGENCY LIGHTING, E LITES NOT THROUGH DIMMER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40283	14041-10000-10973	784 W 25TH ST	90731	15	009B197   495	7463012012	RD1.5-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2972.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Expired	05/19/2016 12:00:00 AM	ADDRESS	33.72166	-118.29433	2 kw PV system for a SFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40284	19041-10000-32503	581 N VIA DE LA PAZ	90272	11	126B125   691	4412017018	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Issued	08/28/2019 12:00:00 AM	ADDRESS	34.04009	-118.52903	$0.00 FEE DUE TO AB1414[EPLAN] CHANGES TO APPROVED SET TO RELOCATE EQUIPMENT ON PLAN - CHANGES HAVE BEEN CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40285	14041-10000-15893	5213 E MONTE VISTA ST STE#B	90042	1	151-5A227 248	5469019024	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	Apartment			06/13/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.10885	-118.2008	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40286	10041-10002-11082	2701 N SEPULVEDA BLVD	90049	11	156B141    17	4490001015		West Los Angeles				2623.01	Electrical	Electrical	Commercial			05/13/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.12326	-118.4793	design revision fire alarm for a 5 story commercial bldg. 345 devices and1panels.  ((((((((((  Changes made to previously approved set, they deleted 79 devices and added 76 devices, the new devices are EST and can talk to the panel  final as built  .))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40287	13041-10000-05029	10738 N OVERMAN AVE	91311	12	207B113    48	2707005034	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2013 12:00:00 AM	03/04/2013 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.26653	-118.57775	PV1 FOR ONE STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 8.085 KW. 33 TOTAL MODULES. [INVERTER: SUNNY BOY. MODEL#: SUNNY BOY 7000-US] [SOLAR PANEL MODULE: BOSCH SOLAR MODULE C-SI M 60]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40288	17041-10000-04324	2909 E 1ST ST	90033	14	126A225    29	5180020032	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.04092	-118.20313	PC for energy only to offce building. Indoor and Outdoor Title 24.  Addition of space for expansion of office. Adding new lighting and power. Total area: 4,738.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40289	13041-10000-20228	2107 S HILLSBORO AVE	90034	5	126B169   330	4302004022	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.04359	-118.39003	PV1 STANDARD PLAN. INSTALLING ROOF MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 8.085 kW .  INVERTER: 1 FRONIUS IG PLUS 7.5 (7500 W) . 3 STRINGS 33 MODULES : TRINA TSM-245. 1 COMBINER BOX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40290	15041-20000-22590	7601 COURAGE WAY	91405	6	186B145  1157			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.2086243	-118.46444911	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40291	16041-10000-11732	5281 N EAGLE DALE AVE	90041	14	165A217    54	5680027003	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.14507	-118.22823	FEES ARE $0 DUE TO SENATE BILL 1222.PV1, INSTALL 13.52 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (52) MODULES: SOLARWORLD SW260 POLY(2) INVERTERS FRONIUS PRIMO 6.0-1 240V:	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40292	15041-10000-05608	431 W 7TH ST 4th Floor	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.04654	-118.25516	TI to (E) restroom space in (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40293	14041-20000-06492	9420 N ENCINO AVE	91325	12	198B129    87	2766018020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	34.24176	-118.51545	PV1 ROOFMOUNTED MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 4.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40294	15041-10001-31364	11533 W DONA PEPITA PL	91604	2	156B169   190	2381024012	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM			Reviewed by Supervisor	09/28/2015 12:00:00 AM	ADDRESS	34.12634	-118.38613	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL NEW 7.6 KWDC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(36) MODULES: SOLAR WORLD PLUS 281 (1) INVERTER: FRONIUS IG PLUS A7.5-1 UNI>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40295	16041-20000-45028	1506 W 228TH ST	90501	15	045B193   413	7347017010	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	33.81885	-118.30411	TENANT IMPROVEMENT AND ADDITION TO (E) WAREHOUSE/OFFICE BUILDING.  PLAN CHECK FOR ENERGY. PERMIT MUST COMPLY WITH CODE ENFORCEMENT ORDER. REFER TO CASE #735539. PERMIT WILL EXPIRE IN 30 DAYS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40296	12041-20003-17445	18600 W DEVONSHIRE ST Sale-Office	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.25704	-118.53922	Modification to previously approved set of plans.  Only change is to go from battery backup exit signs to self-luminous exit signs.         <<<<New panels and circuits for the sales office building.  Plan checked for T-24 and emergency lighting only.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40297	11041-10000-03563	13925 W VENTURA BLVD	91423	4	165B153   474	2271015016	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM			PC Approved	03/22/2011 12:00:00 AM	ADDRESS	34.14904	-118.43628	T-24 REMODEL TO EXISTING MCDONALD'S RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40298	16041-10000-41662	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.04338	-118.26581	Plan check for Title 24 only in existing space Cap Store. Total area: 3,632 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40299	19041-20000-53162	1449 N ELEVADO ST	90026	13	142-5A205 156	5425006034	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.08565	-118.27286	PV1, SOLAR SYSTEM USING CENTRAL INVERTER WITH POWER OPTIMIZERS INTERCONNECTED TO A LOAD CENTER WITH 5.8 KVA ENERGY STORAGE SYSTEM. TOTAL PV SYSTEM SIZE IS 3.78KWDC/3.8KWAC.  TOTAL ENERGY STORAGE SIZE 13.5KWH/5.8 KVA.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40300	10041-20000-23608	3700 N COLDWATER CANYON AVE	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.13809	-118.41286	New fire alarm for Munger Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40301	18041-10000-22308	15335 W CHATSWORTH ST	91345	7	207B145   249	2649002021	QP-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.2647	-118.4665	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40302	13041-20000-22610	24141 W LANCE PL	91307	12	186B089   521	2027049034	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.2046	-118.64879	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.6 KW USING 18 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40303	19041-20000-07468	700 S FLOWER ST 20th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 945 sq. ft.Note: Building permit has been issued under 18016-10000-37396	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40304	14041-20001-17738	1030 N RIVAS CANYON ROAD PV 1	90272	11	129B129   349	4409005009	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	ADDRESS	34.04966	-118.51575	expedite fees9.810 KW ROOF MOUNTED PV SOLAR SYSTEM, this is plan check for transformerless inverter system. 2 inverters. total 10kw AC. original permit issued under application 13041-20000-20253	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40305	12041-10000-30804	7514 N LANKERSHIM BLVD	91605	2	186B169   423	2316013003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM			Reviewed by Supervisor	01/08/2013 12:00:00 AM	ADDRESS	34.20703	-118.38758	T.I. OF RETAIL SPACE. PLAN CHECK FOR POWER AND ENERGY. NEW 600A SERVICE AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40306	16041-10002-14602	18777 W EDLEEN DR	91356	3	168B121   223	2176026016	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.15691	-118.54114	7/14/16: SUPPLEMENTAL TO THE APPROVED SET OF PLAN. REDUCING THE # OF MODULES FROM 42 TO 39 MODULES. PERMIT HAS BEEN PULLED UNDER THE ORIGINL APPLICATION.07/05/16Changes to an approved set. Changes include relocating the PV production meter, AC disconnect and a 400A main service board.Note: Permit paid under PCIS#16041-10000-14602((((PV1 SYSTEM, GROUND MOUNT 10KW DC, CONNECTED TO SINGLE FAMILY DWELLING. 42MODULES.(42)HANWHA Q-CELLS Q.PRO-G3G3 250(1)INVERTER-SMA AMERICA SB 9000TL-US-12-240V	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40307	15041-10000-21643	6543 W FRANKLIN AVE	90068	4	150A187   178	5575005040	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	PIN	34.10545859	-118.33264401	Energy plan check for storage and a corridor of  an apartment building. Total area is 757-SQ feet (indoor and outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40308	12041-10000-00798	10723 S COMPTON AVE	90059	15	088-5A213  47	6065014010	[Q]C1.5-1VL	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	33.93816	-118.24642	New service and panels for a lundry facility plan check for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40309	16041-20000-40144	11285 W GOSS ST	91352	6	192B173   329	2632006007	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.22321	-118.37713	Plan check for installation of roof-mounted solar PV system on commercial building.30kW (10+10+10) ungrounded system. (89) 315W pv modules. Each module has a 400W power optimizer.$23.33 permit fee is due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40310	18041-20001-43743	9201 N MASON AVE	91311	12	198B109   111	2748041013	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM			PC Approved	10/09/2019 12:00:00 AM	PIN	34.23841729	-118.5804491	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOSUDED DELTA 5 CHANGES ONLY. REMOVAL OF FIRE PUMP, RECONFIGURING FLOOR LAYOUT, REMOVAL OF FIRE PUMP ON SINGLE LINE, RENAMING MAIN PANEL, RECALCULATED LOADS ON PANELS, ADDITION OF LIGHTS TO INDOOR T24 SHEETS, AND RELOCATION/ADDITION OF OUTLETS. MINOR CHANGES TO ALL PAGES EXCEPT PAGE 8.*ORIGINAL*Plan check for power and energy. Project site is a new 1-story warehouse. Work includes a 1,600 Amp service and a total lighting of area 61,774 sq. ft.Note: Building application has been generated under 18010-20000-00336	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40311	11041-10000-25397	808 E 62ND ST	90001	9	105B205   803	6007010008	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			PC Info Complete	07/20/2012 12:00:00 AM	ADDRESS	33.98312	-118.26075	New 49KW rooftop photovlotaic system for an existing commercial building.   218 panels and 3 inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40312	19041-20000-22673	6053 W CENTURY BLVD 11TH FL	90045	11	093B169   305	4124030902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.94648	-118.38998	T24 ONLY PLAN CHECK POWER AND ENERGY ONLY IN EXISTING HIGH RISE COMMERCIAL 11TH FLOOR. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 15,452 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40313	13041-10000-06858	16366 W MANDALAY DR	91436	5	162B137   230	2286003001	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.14142	-118.48989	photovoltaic system for single family dwelling. 2 story dwelling. total system size 14.4 kw. using total of 60 panels and 3 central inverters. nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40314	15041-20000-34146	19115 W STAGG ST	91335	3	189B121   595	2104010010	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.21119	-118.54975	PV1, roof maounted solar 7.42 kW system. (28) modules: #KU2656ZPA, (1) inverter: PVI-6000-OUTD-US-Z-A. Simplified std. plan provided	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40315	16041-20000-20530	18231 W LOS ALIMOS ST	91326	12	207B125   201	2715010022	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.26557	-118.53098	PV1.  Install 7 kW roof mounted PV system.  (25) modules with microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40316	15041-10000-39251	5074 N GLEN IRIS AVE	90041	14	162A223   168	5686007013	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM			Reviewed by Supervisor	01/28/2016 12:00:00 AM	ADDRESS	34.13845	-118.20942	PV1, ROOF MOUNTED SYSTEM USING A BATTERY CHARGE SYSTEM. (12) MODULES AND (1) 3KW-AC INVERTER. TOTAL SIZE 3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40317	18041-20001-40030	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM			PC Approved	12/07/2018 12:00:00 AM	ADDRESS	34.1937	-118.49152	12-07-2018 Changes to an approved set of plan. Changes include replace battery with different manufacture. All Changes has been clouded.  Note to  Inspector: Please verify UL listing for battery product. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40318	16041-10000-04549	4456 S SLAUSON AVE	90230	11	111B161   862	4217018033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/19/2016 12:00:00 AM	ADDRESS	33.9978	-118.4132	PV1, rooftop solar installation 3kW.(7) Triex U290 Black(1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40319	10041-20000-10199	8900 N DE SOTO AVE BLDG 101	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	05/28/2010 12:00:00 AM		Permit Finaled	04/21/2011 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check T-24 Energy general/emergency lighting for TI work in the locker area of Bldg 101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40320	17041-10000-02585	505 S VIRGIL AVE #203	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.0649	-118.28724	Plan check for power and energy Medical treatment room T.I. in Physical Theraphy Alpha Rehab. Total area: 1,935 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40321	13041-10000-05671	18302 W HASTINGS WAY	91326	12	213B125   375	2870011015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.2798	-118.53268	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.36 KW USING 39 MODULES. CENTRAL INVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40322	19041-10001-43215	7008 W WOODROW WILSON DR	90068	4	157-5A181 369	2429020012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.12488	-118.34673	Change to and approved set , changing the layout of pv modules only.Original scope:Plan check for a new 10kW AC/ 12.78KW DC PV1 roofmounted system. Scope includes (1) inverter, (35) modules and optimizers inter connecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40323	16041-30000-23887	132 N SWALL DR 1-14	90048	5	138B169   260	4335001094	R3-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.07622	-118.38569	Plan check for a fire alarm system for a 4-story apartment building. Fire alarm system consists of (1) FACP, (1) communication panel, and (66) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40324	14041-20000-35274	5735 N COLUMBUS AVE	91411	4	174B145   240	2243005006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM			PC Approved	12/19/2014 12:00:00 AM	ADDRESS	34.17491	-118.46418	REVISION TO AN APPROVED SET OF PLANS REFERENCE NUMBER 14041 20000 32919.ROOF MOUNTED MODULE LAYOUT CHANGE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40325	17041-10000-19487	15123 W VENTURA BLVD	91403	4	168B145   960	2264007017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.15337	-118.46238	"PC FOR TI-24, ENERGY ONLY  TI FOR "" LANNA MASSAGE"".TOTAL AFFECTED AREA 691 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40326	17041-10000-20864	650 W 35TH ST 4th floor	90089	9	120A201    96	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.02162	-118.2827	Title 24 plan check.  T.I. to 4th floor of existing educational building to convert from library to office. Replace 4 subpanels and add 3 new subpanels.  Total new connected load < 400 amps.  New lighting and receptacles.  Lighting area = 10,955 sq. ft.       Building permit #17016-10000-04201	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40327	13041-10000-05744	380 WORLD WAY #T73-T74	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLAN CHECK POWER AND ENERGY FOR CONCESSION SPACE T-73 & T-74 (LUCKY FISH)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40328	12041-10000-30556	6837 W HAWTHORN AVE	90028	13	147B181   265	5548006009	CR-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM			Reviewed by Supervisor	02/08/2013 12:00:00 AM	ADDRESS	34.10045	-118.34003	((((((({{{{{{{ Applicant came back for resubmittal. New plans has the following changes: Service 1600A}}}}]]]]]((((((( Applicate will bring new set of plans. New submital and recalculation of fees is required.)))))))                   New office with attached 6 story parking garage (non-high rise structure). New 2000A service supplying structure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40329	19041-10000-51325	7823 S MAIN ST #1-#47	90003	9	099B201   547	6031019015	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.02	Electrical	Electrical	Apartment			12/12/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	12/02/2022 12:00:00 AM	ADDRESS	33.96823	-118.27406	PC FOR POWER AND LIGHTING FOR A NEW 1200 AMP 120/240 V 3 PHASE 4 WIRE SERVICE. TOTAL AFFECTED AREA 20086sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40330	19041-10000-00302	8500 W BEVERLY BLVD #157	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	New retail store The Webster LA8750 SQR FT. FULL PLAN CHECK.BULDING PERMIT: 18016-10000-34753	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40331	17041-20000-04482	6969 N DEERING AVE	91303	3	183B105   350	2138014905	PF-1XL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.19719	-118.59695	PLANCHECK FOR POWER AND ENERGY. INSTALLATION OF NEW 800 AMPS SERVICE AND 600 AMP MOTOR CONTROL CENTER. ALL MOTORS ARE EXISTING TO BE RECONNECTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40332	14041-10001-09029	301 N BRISTOL AVE	90049	11	132B137   155	4406007023	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.06059	-118.48921	(((EXPEDITE FEES)))PV1 ROOF MOUNTED NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 14.9KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40333	16041-20001-06285	5750 W WILSHIRE BLVD 5th Floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	34.06227	-118.3542	12.2.2016 - Plan check for modifications to approved set - As Built plans. Feed DB5 from MSB-B instead of MSA-A. Upsize DB5 to 400A bus, upsize feeder accordingly. Relocate UPS and change it to 480V 50KVA. New panel 5LE1 with new receptacle circuits. Minor updates to lighting design. Delta E changes.======FULL PC TO A TI IN AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING, LOAD AND A DISTRIBUTION BOARD 'DB5'WITH A UPS SYSTEM.  TOTAL SQ. FT. 35,733.Note: Building application has been generated under 16016-10000-03467	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40334	13041-10001-14008	20012 W ROMAR ST PV 1	91311	12	204B113   441	2726024008	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.25431	-118.56959	PV1  2.205 KW XFRMless. 1 STORY. nonSTD. ROOFMOUNT.  [ 1 INV: POWERONE PV-3.0-OUT-S-US ] [ 9 MOD: TRINA TSM-245PC05.18} ] solar clearance obtained on original (which was originally a transformer system - now it has been changed to transformerless).INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.  2.205 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40335	18041-10000-38853	777 S FIGUEROA ST SUITE 3850	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	REMODELING OF OFFICE SPACEPLAN CHECK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40336	18041-20000-24817	3105 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.02993	-118.37353	Plan check for 1st time tenate manufacturing building. Total area: 10,108 sq ft. B#18016-30000-16773 (1st time tenate per applicant )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40337	17041-20001-22165	11926 W OXNARD ST	91606	2	177B165   766	2339003020	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.17926	-118.39314	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with AC coupled battery backup system for SFD.3.8kW ungrounded system. (14) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40338	11041-10000-19587	4101 N MARY ELLEN AVE	91604	5	162B157    93	2385024016	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2011 12:00:00 AM	11/03/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.14389	-118.41985	7.14 KW PV system for  one  story SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40339	14041-20000-03472	14971 W FOOTHILL BLVD	91342	7	228B145    89	2502002021	RA-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.32265	-118.45958	PV1 SINGLE FAMILY DWELLING ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE 18KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. 3 SOLAR EDGE USING POWER OPTIMIZERS. SYSTEM TAPPING AHEAD OF THE MAIN. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40340	16041-10000-37256	5626 N TUJUNGA AVE	91601	2	174B173   815	2337039010	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.17271	-118.3789	PC FOR ENERGY(T24). CHANGE OF USE FROM EXISTING AUTO SALES AND AUTO REPAIR BUILDING TO PROPOSED CAR RENTAL OFFICE, VEHICLE STORAGE AND CAR WASH AND PARKING LOT. TOTAL AREA  14765 SQ FT. B # 16016-10000-20757	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40341	18041-10000-08340	19400 S HARBORGATE WAY #A	90501	15	057B193   127	7351003011	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	33.85402	-118.30332	PC FOR ENERGY ONLY TO AN OFFICE BUILDINGS TENANT IMPROVEMENT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE TO A PORTION OF BUILDING A. TOTAL SQ. FT. 4199.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40342	17041-30001-02249	3831 S HUGHES AVE	90232	5	120B165  1276	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/27/2017 12:00:00 AM	ADDRESS	34.02242	-118.39823	07/25/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4. Changes have been made to the detail notes on the plans and to the lighting plan. All changes have been reflected onto the Title 24 compliance certificates.*****Previous Work Description*****Title 24 plan check.  T.I. to ground floor building entrance including garage ramp and lobby in existing commercial medical highrise.  Total area = 2,720 sq. ft.  Building permit #16016-20000-17436	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40343	19041-20000-29263	4915 N LIBBIT AVE	91436	5	168B137   276	2260008015	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.15878	-118.48817	Plan check for PV roof mounted system, system size: 13.52KW DC, 12KW AC with 50 PV Modules and 2 inverters(6.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40344	15041-20001-28643	7917 S MAIN ST	90003	9	099B201   650	6031024015	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	33.96737	-118.27406	Expedited per customer request.PV1. Install roof mounted PV system sized 2.5 kW. Interconnected with main service panel.(9) LG280 Modules(1) ABB UNO-2.5 Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40345	18041-20000-45043	24320 S ROSCOE BLVD	91304	12	192B089   203	2017039014	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.21899	-118.65576	Plan check for PV roof mounted system, system size: 2.835kW with 9 PV Modules with 1 inverter(3.0kw)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40346	17041-20000-10935	21600 W OXNARD ST suite 1600	91367	3	177B105    84	2146006043	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.179	-118.6002	ti to an existing commercial building 16th floor.  adding new lighitng ew controls to existing panels.  plan check for energy only.  total square footage 19169.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40347	17041-20000-22106	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	Plan check for energy only. TI/Change of use of portion of building on first floor of a high rise building from office to restaurant (Subway). New lighting (incl. emergency) - 945sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40348	19041-20001-03448	5234 E BALTIMORE ST pv1	90042	1	154-5A225 270	5478017007	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	34.11775	-118.20213	$0 PERMIT FEE DUE TO AB1414 AND SB1222SUPPLEMENTAL PLAN CHECK ONLY CHANGES TO APPROVED SET, UPDATE TO SCOPE OF WORK, PLAN CHECK FOR SYSTEM DESIGN REVISION; REMOVING THE ESS, LOAD CENTER, AUTO TRANSFORMER, MINOR CHANGE IN CONDUIT SCHEDULE/SINGLE LINE DIAGRAM LABELING, AND CHANGE IN PV MODULE MODEL FROM 330 TO 360W AND OPTIMIZER FROM P320 TO P370*ORIGINAL*pv1install roof mounted pv system sized 3.8KW interconnected with msp.(1) LG CHem battery 5KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40349	18041-20000-05506	1141 N MANSFIELD AVE Ground-Floor	90038	4	144B181   360	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.09202	-118.34057	Plan check for Title 24 only. Project site is the ground floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 14,344 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40350	17041-20000-40048	15851 W LASSEN ST	91343	12	201B141   187	2669025006	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.25025	-118.47813	pv1install roof mounted pv system sized 10kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40351	14041-10005-09802	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	PER NABIL:PLANS REFLECT CHANGES MADE TO PERMITTED SET OF PLANS UP TO BULLETIN 2ALL CHANGES ARE CLOUDED ON THE PLANSPLAN CHK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40352	16041-10000-36068	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	PIN	33.93847109	-118.41935625	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HANGER AT BAY 6 BREAK ROOMS. SCOPE INCLUDES ADDING/REPLACING NEW LIGHT FIXTURES FOR BREAKROOMS 101 & 102. B#16016-10000-24419	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40353	17041-10000-14624	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.23342	-118.3809	NEW SCALE HOUSE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40354	18041-10000-20692	14723 W AETNA ST	91411	6	177A149    68	2241025002	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.18023	-118.45394	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40355	12041-10000-14727	2001 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM	12/05/2012 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	PIN	34.06587468	-118.19737837	Change to lighting, receptacles for an existing warehouse.  All panels are existing.   Load is less than 400A.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40356	10041-20000-20567	20250 W SHERMAN WAY	91306	3	183B113    60	2135001046	[Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.20085	-118.57478	PLAN CHECK POWER AND ENERGY FOR 7-ELEVEN TI WITH NEW 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40357	14041-20000-03698	1378 E MORNINGSIDE WAY	90291	11	114B149   907	4244020023	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Expired	03/07/2016 12:00:00 AM	ADDRESS	34.00585	-118.4537	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan. using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40358	16041-20000-15435	7888 N VAN NUYS BLVD D2	91402	6	189B149   639	2212028015	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.21514	-118.44612	TI TO AN EXISTING COMMERCIAL SPACE.  600 AMP SERVICE FROM EXISTING DISTRIBUTION BOARD.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 11015.BUILDING APPLICATION NUMBER 16016-20000-09918	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40359	15041-10001-16344	11533 W DONA PEPITA PL	91604	2	156B169   190	2381024012	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.12634	-118.38613	PV1, INSTALL 10.080 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(36) MODULES: SOLARWORLD PLUS SW 280 MONO BLACK(1) INVERTER: FRONIUS IG PLUS A 7.5-1 UNI 240 V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40360	14041-10001-05211	421 S MAIN ST	90013	14	129A211    92	5149022010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/02/2014 12:00:00 AM			PC Approved	07/02/2014 12:00:00 AM	ADDRESS	34.04765	-118.24788	((7/2/2014- Changes made to approved set. Added some light fixtures. T24 to be verified))TI to existing commercial space for new restaurant.  Restaurant occupancy load below 100 occupants.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40361	16041-10000-40343	16808 W LIGGETT ST	91343	12	198B137   464	2687009013	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.23996	-118.49849	PV INSTALL A NEW 6.480 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMIL;Y HOUSE.(18) AC MODULES: SUNPOWER SPR-X22-360-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40362	17041-10000-15276	10250 W SANTA MONICA BLVD #1970	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PC FOR FIRST TIME TENANT IN WESTFIELD CENTURY CITY ""AMAZON BOOKS"". SUITE 1970, 5,227 SQ.FT"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40363	15041-10002-20264	12905 W LANDALE ST	91604	2	165B161    71	2362006013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	04/06/2021 12:00:00 AM	ADDRESS	34.15231	-118.414	PC FOR CHANGES TO AN APPROVED SET.  SCOPE INCLUDES NEW LIGHT FIXTURES SCHEDULE. EMERGENCY LIGHTING POWER CHANGES FROM INVERTER CONNECTED TO 90 MINUTES BATTERY BACKUP.  TOTAL AFFECTED AREA IS 13569 SQ, FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40364	14041-20000-10925	9549 S DEFIANCE AVE	90002	15	093A213   229	6048021032	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	33.94918	-118.24539	PV1.  mounted-roof system with (16) micro inverter enphase M215-60-2LL-S22, and (16) module of Canadian solar CS6P 250P, 250 watt each. total AC: 3.44kw.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40365	19041-10000-29545	12641 N BRADFORD PL	91344	12	219B129   442	2601061010	RE11-1-H, RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.29662	-118.52053	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.375KWdc / 14.186KWac CEC. (41)MODULES- 375W TSM-DE14A(11) PERC(41)OPTIMIZERS SOLAREDGE P400(1)INVERTER SOLAREDGE SE11400H-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40366	18041-10001-06179	1925 S TUDOR LANE	90034	10	126B173  3095	6207036031	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM			Reviewed by Supervisor	02/28/2018 12:00:00 AM	ADDRESS	34.04074	-118.37113	Void application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40367	12041-10001-16647	13488 W MAXELLA AVE	90292	11	105B153   739	4212004032	[T][Q]RAS4-1, [T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM			PC Approved	11/01/2012 12:00:00 AM	ADDRESS	33.98592	-118.44252	Revision to approved plans. Delta 5. Changes to loads. New restaurant, first time tenant.  Full Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40368	18041-10000-42703	734 S MAIN ST	90014	14	127-5A211 186	5145001001	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.04318	-118.25216	"TI IN AN EXISTING 4 STORY OFFICE BUILDING. INSTALLING NEW LIGHTS IN THE COMMOEN AREAS. THE TOTAL NEW ADDED LOAD IS LESS THAN 400 AMPS. (SUBJECT TO FIELD INSPECTION).T-24 ENERGY ONLY. EACH NEW TENANT REQURES COMPLETE PLAN CHECK. BUILDING PERMIT"" 18016-10000-05811"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40369	12041-10000-01052	18705 W STONEHAVEN CT	91326	12	216B121   277	2872023003	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	34.28862	-118.5409	New 8.46kw rooftop, photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40370	12041-10000-16076	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM			PC Info Complete	08/22/2012 12:00:00 AM	ADDRESS	34.10158	-118.3062	Plan check for energy and power. Restaurant. Single story commercial. 120 occupants per applicant. 4653 sqft. Parasolnine Thai Restaurant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40371	18041-10000-05403	1701 S VERMONT AVE #C	90006	1	126B197   374	5075016028	[Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.04252	-118.2918	PC for T24 only for new lighting for message parlor. Installing new lights, receptacles and equipment. Total area is 950sqft. B# 18016-10000-04100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40372	15041-20000-11542	11339 N GAYNOR AVE	91344	12	213B141   435	2666015004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.2765	-118.48137	Plan check for PV1 roof mounted 3.8kW system with 21 modules(KYOCERA KD255GX-LFB3) and 1 inverter()	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40373	13041-20000-15236	3717 S GRAND AVE	90007	9	117A203    47	5122025006	[Q]C2-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.01615	-118.27889	Ti for three story only xpress permit on 3rd floor.USC office space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40374	18041-10000-09089	985 S SEASIDE AVE	90731	15	015B205    18	7440032904	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Info Complete	11/20/2018 12:00:00 AM	PIN	33.73479274	-118.26921687	PC FOR POWER AND ENERGY FOR PROPOSED 78,335 SF SINGLE STORY STEEL FRAMED MANUFACTURING FACILITY IN THE PORT OF LOS ANGELES. SCOPE INCLUDES 5KVA FEEDERS,  SWITCH BOARDS (480/277V  4000A),  PANELS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 296276 SQ.FT (INDOOR + OUTDOOR)B#18010-10000-01108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40375	17041-20001-23853	6560 W FOUNTAIN AVE	90028	4	144B185   157	5533001004	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.09412	-118.33247	12/18/2018changes to an approved set of plans.  changes to reflect field conditions to pull section and distribution boards MSA and MSB.this is plan check only.((((New 5-unit 2-story apartment building.  600A 240/120V single phase service.  Plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40376	16041-20000-27089	4151 W PROSPECT AVE Bldg NTC	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,377 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40377	11041-10002-10270	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.14947	-118.43885	PLAN CHECK ONLY FOR REVISION R2. REVISE FEEDER SIZE FOR LK/LKA  PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40378	17041-10000-11978	5425 N VAN NUYS BLVD	91401	4	174B149  1185	2249003005	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1288.02	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.16924	-118.44896	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 64225 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40379	12041-20000-29026	2706 W WILSHIRE BLVD	90057	1	133-5A201  94	5141011016	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM	02/04/2013 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.06093	-118.28296	Plan check for power only. New electrical system for water damaged building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40380	14041-20001-17070	19957 W CANTARA ST	91306	3	192B113   664	2106001038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.21894	-118.56859	Expedite per customer request7KW PV1 roof-mounted system with (28)Canadian Solar  modules 250Px,  and Solaredge P300 power optimizers connecting through a Solaredge SE6000A-US  transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40381	18041-10000-16443	328 E 1ST ST	90012	14	129A215    10	5161017031	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04967	-118.24011	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40382	13041-10000-10225	801 W 7TH ST	90017	10, 14	129A209    49	5144008009	C2-1, C2-4D	Central, South Los Angeles	Central City, West Adams - Baldwin Hills - Leimert	Downtown Los Angeles, South Robertson		2077.10, 2696.01	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM			Corrections Issued	04/23/2013 12:00:00 AM	ADDRESS	34.04887	-118.25879	TI for a Coffee Bean and Tea Leaf.  Project consists of replacing interior finishes and changing out light fixtures and removing outlet receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40383	11041-10000-19376	515 S FLOWER ST DRAGO-PATIO	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM			PC Approved	09/13/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	NEW PATIO LUMINAIRES FOR EGRESS LIGHTINGPLAN CHK IS FOR TITLE 24 OUTDOOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40384	17041-10000-01967	1051 S QUEEN ANNE PL	90019	10	132B185   753	5082001011	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2017 12:00:00 AM			Reviewed by Supervisor	01/30/2017 12:00:00 AM	ADDRESS	34.05558	-118.33003	PV1 roof mounted solar system with Tesla battery backup rated at 3.5 KW. Syste size: 7.6KW solar edge inverter with 8 solar modules. Variance has been issued for listing Auto-transformer under the app No. 500836.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40385	15041-20001-07863	7202 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			PC Approved	05/18/2015 12:00:00 AM	ADDRESS	34.24844	-118.28882	Plan check to change to approved set of plan. Changes include replace fixture A with fixture B and add daylite  sensors. ******Plan check for power and Title-24 (energy).  Total area = 1,639 sq. ft.T.I. to first time tenant nail salon.  3 new panels.  New lighting and recepticles.********	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40386	15041-10000-09123	5441 N DENNY AVE	91601	2	174B177   959	2416016003	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.16965	-118.36471	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3720 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40387	13041-20000-33206	1000 N HIGHLAND AVE	90038	4	144B185   952	5532027014	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Info Complete	01/14/2014 12:00:00 AM	ADDRESS	34.08908	-118.33841	PC FOR POWER AND ENERGY. NEW RETAIL. EXISTING WAREHOUSE. CHANGE OF USE. TOTAL AREA 28881 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40388	13041-20002-33360	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016021	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Apartment			09/08/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.08758	-118.34425	09-08-2015 Change to approved set of plans(179 unites appartment). Changes include  added 2 transformers, 3 wires size increse, lug kit added to MSB1, house meter load increse, Title 24 outdoor lighting and added pole lights . Changes apply to Delta PC2 only. {{{{{New 179-unit apartment building in Methane Buffer Zone.  Install two new services, 2500A and  2000A, panels and lighting.   Plan check for power and energy.Note: Variance to separate fire alarm submitted}}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40389	10041-20000-03703	1714 N MCCADDEN PL 1-218	90028	13	148-5A185  86	5547010011	(Q)C4-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			03/02/2010 12:00:00 AM			PC Approved	04/05/2010 12:00:00 AM	ADDRESS	34.1021	-118.3373	REVISION DELTA 3 AND ADDITION DELTA 4 TO AN APPROVED PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40390	11041-10000-17990	350 S FIGUEROA ST Ste 370	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	34.05438	-118.2549	T.I.  High rise office building.  Remodel of light fixtures in Suite # 370 (Phase II) .  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40391	15041-20000-33955	5210 W OLYMPIC BLVD 1-8	90036	10	132B181   703	5084011018	R3-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Apartment			10/13/2015 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.05691	-118.34296	PLANCHECK FOR A NEW 8-UNIT MULTI-FAMILY APARTMENTS. FIRE ALARM HAS BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40392	11041-20001-25701	601 S FIGUEROA ST Ste 3875	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	Changes from previously approved of the high rise building on the 38th floor.  T.I.  Remodel of the light fixtures in Ste 3875. Changes include replaced lighting fixtures.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40393	18041-10000-25024	922 S STANLEY AVE	90036	4	132B177   603	5089015006	R2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.05839	-118.35754	Installing 2 new Power Walls (13.5KWH each) with existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40394	18041-20001-00034	11287 W ALLEGHENY ST	91352	7	201B173   239	2538022013	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.24849	-118.37779	expeditepv1install roof mounted pv sysem sized 11.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40395	15041-10001-10269	1140 S ORLANDO AVE	90035	5	132B173   897	5087009008	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2015 12:00:00 AM			PC Approved	06/02/2015 12:00:00 AM	ADDRESS	34.05598	-118.37375	Expedited plan check pera applicant request,.<<<<Install new 8.82 kw dc roof-mounted solar array on a single home family, tie with main service panel.(27) modules: sunpower spr32ne-wht-d(2) inverter: sma sb5000tl-us-22 & sb3800tl-us-22>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40396	12041-10000-04358	6022 W AVION DR Term C-C1	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM			PC Info Complete	03/13/2012 12:00:00 AM	ADDRESS	33.94182	-118.39269	Plan check for temporary power for vending machine equipment during construction at Termincal C. Plan check per applicant request. Panelboard, equipment, and branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40397	10041-20000-13857	17401 W VENTURA BLVD B19	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.16136	-118.51189	TI FOR BEAUTY SALON. ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40398	10041-20000-10169	10560 W MAGNOLIA BLVD Building A	91601	4	171B177   735	2419017001	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM			PC Info Complete	08/19/2010 12:00:00 AM	ADDRESS	34.16472	-118.36133	Plan check T-24 general/emergency indoor and outdoor lighting for new addition of repair garage (Building A) and office space (Building B) to existing repair garage space (Building C). Building B on permit #10041-20000-16298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40399	17041-20000-26295	1906 S OVERLAND AVE 1-16	90025	5	129B157   565	4321008018	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			08/02/2017 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	04/09/2021 12:00:00 AM	ADDRESS	34.05011	-118.43148	Plan check for power and energy. Project site is a new 4-story, 16-unit apartment building. Work includes a new 1200-amp service and a total lighting area of 18,006 sq. ft.Note: Building application has been generated under 16010-20000-05146	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40400	15041-20000-05962	10152 W BRADLEY AVE	91331	7	204B165   199	2537005011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	PIN	34.25534926	-118.40346136	Installation of new roof mounted solar PV microinverter array.  Total system size = 5.59 kWacNote: PV plan check over the counter because B contractor can not pull permit online.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40401	17041-10000-04066	5200 N LANKERSHIM BLVD #390	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	T-24, PC FOR ENERGY ONLY. INTERIOR OFFICE TI TO AN EXISTING COMMERCIAL BUILDING FOR OFFICE AND CONFERENCE SPACES. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES FOR SUITE 390. TOTAL AFFECTED AREA IS 1448 SQ. FT. B#16016-10000-30075	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40402	18041-10000-15377	17950 W PARTHENIA ST	91325	12	195B129   429	2787001019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.22845	-118.52472	$0.00 Permit Fee per senate bill 1222.INSTALL A NEW 17KW PV SYSTEM WITH 54 MODULES AND BACKUP BATTERIES ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40403	08041-20002-05790	13833 W VENTURA BLVD	91423	4	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.1487	-118.43426	The delta 4 change to the plan to remove permitting of the space 102, 103, 105, 201, 202, 204, and 205 of the new building.  The indicated tenant spaces will obtain permits separately.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40404	16041-10000-34175	505 S VIRGIL AVE #206	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.0649	-118.28724	FULL PC FOR POWER AND ENERGY TO AN EXISTING MEDICAL OFFICE. SCOPE INCLUDES NEW RECEPTACLES FOR AN EXISTING THERAPEUTIC ROOM, CONSULTING ROOM, AND RECEPTION AREAS(GENERAL CARE ONLY, NON-INVASIVE PROCEDURES). TOTAL AFFECTED AREA IS 1575 SQ. FT. B#16016-10000-21928	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40405	16041-10000-28228	5711 N FIGUEROA ST	90042	1	151-5A229 174	5492001014	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM			PC Info Complete	08/09/2016 12:00:00 AM	ADDRESS	34.10989	-118.19257	PC FOR ENERGY ONLY. T.I. of (E) two retail spaces, including front facade. main switchboard is 400A. Total affected area is 2238 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40406	17041-10000-22481	2712 N CASIANO ROAD	90077	5	156B141   115	4378030015	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	07/15/2017 12:00:00 AM	ADDRESS	34.12047	-118.47231	Installation of roof mounted solar PV system on existing single family dwelling.  Total system size = 10.72 kWac.  AC module system.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40407	19041-20000-08601	12317 N FINCH ST	90039	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	PIN	34.3012906	-118.58563914	PV1.  Install 5.03 kW roof mounted grid tied PV system.  (15) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40408	16041-20000-01677	5503 N CAHUENGA BLVD	91601	2	174B177   903	2416020034	CR-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.17016	-118.36174	TI to existing commercial building (offices). Plan check for energy only. Adding new lighting. Total sqft. 8350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40409	11041-20001-00820	3335 S FIGUEROA ST UGY #1	90007		120A203   177	5123009027	(Q)C2-2D-O		South Los Angeles	Empowerment Congress North Area			Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM			Reviewed by Supervisor	04/07/2011 12:00:00 AM	ADDRESS	34.02224	-118.28008	Plan check power only. First time tenant UGY#1. T24 Energy approved under #11041-20000-00820	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40410	12041-10001-16683	333 S ALAMEDA ST	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM			PC Approved	10/11/2012 12:00:00 AM	ADDRESS	34.04448	-118.23824	Revision to approved plan. Change T24 calc. EPC is for delta 3. ((((((((((((((((((((((((full plan check per owners request, title 24 and emergency lighting, 5 new panel , arcade, restaurant, bowling. must use area catagory. plann check for power and energy.))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40411	14041-20000-15340	5909 N WILKINSON AVE	91607	2	177B165  1011	2340001072	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.17768	-118.40429	PV1.  Install 5.2 kW roof-mounted, utility-interactive PV system.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40412	16041-10000-03837	12741 W VENTURA BLVD	91604	2	165B161  1006	2375021017	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.14491	-118.41084	TI on (E) commercial build. from retail to golf practice. PC on T-24 only. Install new light fix. and control receptacles. Total area: 1,750sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40413	15041-20000-04108	12945 N GLENOAKS BLVD	91342	7	222B149   490	2505018060	RA-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2015 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.30568	-118.44756	CHANGES TO AN APPROVES SET OF PLANS.  ADDING DEDICATED CIRCUIT FOR PV MONITORING.REFERENCE APPLICATION NUMBER 15041 20000 01612.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40414	17041-10000-15712	9601 N OWENSMOUTH AVE	91311	12	201B105   222	2746016030	MR1-1, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24466	-118.60264	T24 ONLY. REPLACE EXISTING HID LIGHT FIXTLURES WITH NEW LED LIGHT FIXTURES. TOTAL ARE  A  33400 SQ FT. OUTDOOR  LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40415	12041-20000-03942	6100 W WILSHIRE BLVD 2nd & 3rd-floors	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			PC Approved	03/16/2012 12:00:00 AM	ADDRESS	34.06282	-118.36187	Remodel on the 2nd and partial 3rd floor.  Plan check for T24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40416	14041-10000-05925	23441 S BATEY AVE	90710	15	042B197    85	7438013034	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	33.8112	-118.29942	PV1. ROOFMOUNTED SOLAR SYSTEM. NON-STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 5.39 KW DC.(22) TRINA SOLAR TSM-245(22)  ENPHASE M215 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40417	18041-10000-22310	10839 N SAN FERNANDO ROAD	91331	7	207B157   205	2619016076	[Q]C2-1-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.26694	-118.4233	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40418	19041-20000-10308	1835 S MESA ST Lot 20	90731	15	012B201   795	7456029046		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	33.72719	-118.28613	Plan check for PV roof mounted system, system size: 3.02KW 9 AC Modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40419	11041-20000-21078	7200 N VINELAND AVE	91352	2	183B173    68	2410019037	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	05/25/2012 12:00:00 AM	ADDRESS	34.20168	-118.37011	Change of use according to building permit.  Inspector has asked for a full plan check.  New bakery to occupy former swap meet space.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40420	19041-10000-38013	1343 N GLENDALE BLVD	90026	13	141A209   719	5419032002	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1956.00	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.07952	-118.26049	T-24 PLAN CHECK FOR A TI OF EXISTING RETAIL STORE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1776 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40421	17041-20000-34224	5670 W WILSHIRE BLVD 11TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for energy only. TI to restrooms on 11th floor. New lighting (incl. emergency) - 330sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40422	15041-20001-10698	4428 N DENSMORE AVE	91436	5	165B141   117	2283007013	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			PC Approved	05/08/2015 12:00:00 AM	ADDRESS	34.15167	-118.47735	Expedite per applicant request******Plan check for PV1 roof mounted 10.92kW system with 2 inverter(ABB # PVI-6000-OUTD-UYS-Z-A, ABB #PVI-4.2-OUTD-S-US-Z-A) and 42 modules (kyocera # ku2606xpa) and 1 load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40423	17041-10001-19353	5026 S DENKER AVE	90062	8	111B193  1269	5016034011	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Issued	09/01/2017 12:00:00 AM	ADDRESS	33.99739	-118.30441	Supplemental PC for changes to number of PV modules, addition of 200A subpanel and change of address.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40424	19041-10000-38575	2921-2923 W FLORENCE AVE	90043	8	102B189  1282	4008026013	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	33.97472	-118.32524	TI IN AN EXISTING COMMERCIAL AREA. INSTALLING NEW LIGHTS, T-24 ENERGY ONLY. PLAN CHECK ONLY. AREA: 1635 SQR FT.ELECTRICAL PERMIT: 19041-10000-31214BULDING PERMIT: 18016-10000-22888	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40425	10041-10000-05250	9200 N GLENOAKS BLVD	91352	2	198B173   111	2408001003	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.00	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	34.2363	-118.37296	Plan check power of new installation for CNG facility.  Electrical driven compressor.  Site is in methane buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40426	19041-10000-09527	9532 N MCLENNAN AVE	91343	12	201B133   596	2686026013	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.24415	-118.50091	PV1, NEW ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTERS. (31) MODULES, (2) INVERTERS, 3.0KWAC AND 7.7KWAC. TOTAL SYSTEM SIZE IS 10.7 KWAC, 10.466KWDC, 11.16KWP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40427	15041-20000-36290	16830 W VENTURA BLVD STE.364	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.15886	-118.50032	TI on (E) high rise office build. scope of work on Ste. 364. PC for Energy only. Total area: 1210 sq.ftAll branch circuits are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40428	19041-30000-21054	1301 S WESTGATE AVE 1-8	90025	11	126B145    57	4263023020	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Apartment			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	09/26/2021 12:00:00 AM	ADDRESS	34.04507	-118.46183	Plan check for a fire alarm system for a 4-story, 27-unit apartment building. Fire alarm consists of (1) FACP and (126) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40429	13041-20000-14551	130 W BRUNO ST	90012	1	135A215   352	5409008016	[Q]C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM			Corrections Issued	10/17/2013 12:00:00 AM	ADDRESS	34.06238	-118.23569	CONSTRUCTION OF PV2 PHOTOVOLTAIC SYSTEM ON COMMERCIAL STRUCTURE. TOTAL SYSTEM SIZE 6.7 KW. USING 28 PANELS. ROOF MOUNTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40430	17041-20001-10412	7737 N DEERING AVE	91304	3	189B105   571	2109030043	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM			PC Approved	08/14/2017 12:00:00 AM	ADDRESS	34.21094	-118.59678	8/14/17changes to an approved set of plans.  changes to reflect field conditions.this is plan check only.  (((Service upgrade 600 A 120/240V 3ph/4w for light industrial building.  Plan check for power.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40431	11041-10000-06137	845 S FIGUEROA ST	90017	9	129A207   195	5144022036	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.04698	-118.26234	New fire alarm system for 5 story appartment Bldg. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40432	19041-10000-35846	12614 W JUDD ST	91331	7	213B161   516	2532019003	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	34.28046	-118.408	$0 PERMIT FEE DUE TO SB1222 AND AB1414[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10.6KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE7600A-US AND SE3000H-US) WITH 39 MODULES USING P320 OPTIMIZRS AND ESS(LG CHEM RESU 10H). MAIN PANEL UPGRADE TO BE SEPARETLY PERMITTED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40433	13041-10000-29570	9714 N ORCAS AVE	91040	7	201B173   350	2542023010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.24575	-118.36701	PV1.  Install 12.25 kW DC roof-mounted solar array, interconnect with main service panel.  Multiple inverters.  50 modules: Yingli Yl245p-29b.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40434	15041-20000-42887	20310 W BERMUDA ST	91311	12	207B113    59	2707004009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.26604	-118.57608	Plan check for PV roof mounted system. System size: 6.8kWac with 34 modules and 2 inverters(3.0kW and 3.8kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40435	16041-10000-03766	5133 N AUCKLAND AVE	91601	4	171B177   805	2419017023	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.16406	-118.36052	PV1 roof mounted installation to a single family home. Inverter rating: 3.8 kw, (15) Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40436	15041-20000-01284	12101 W MULHOLLAND DR	90210	2	156B165    72	2382018002	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	03/19/2016 12:00:00 AM	ADDRESS	34.12531	-118.40234	PLAN CHECK FOR POWER ONLY. REMODEL OF 2 STORY SINGLE FAMILY DWELLING. UPGRADE SERVICE TO 600A AND COMPLETE REWIRING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40437	12041-10000-01284	400 W WORLD WAY Term. 4-Spc#4D	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. to an existing retail space at LAX, terminal 4, space 4D.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40438	18041-20001-03282	5610 N CAMELLIA AVE	91601	2	174B169   787	2338028019	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			11/08/2018 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	02/03/2021 12:00:00 AM	ADDRESS	34.17257	-118.38211	11-08-2018 Changes to an approved set of plans, Changes include addtion to electric dryer and oven in 62 units multi-family building. All changes has been clouded as delta 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40439	14041-20000-15977	515 S FIGUEROA ST #2000	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Issued	07/02/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	T.I. to a partial of the existing high rise building on the 20th floor.  Install new general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40440	15041-10001-14951	7634 W WOODROW WILSON DR	90046	4	156B177   515	5570031022	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM			PC Approved	08/06/2015 12:00:00 AM	ADDRESS	34.1224	-118.3623	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<,PV1 INSTALL 11.96 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (46) MODULES: KYOCERA  KU2606XPA(2) INVERTER: PVI-4.2-PUTD-S-US-Z-A & 5000-OUTD-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40441	19041-20000-21601	5005 N EDENHURST AVE	90039	13	162B201    20	5593012032	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.142	-118.2736	NEW ROOFTOP PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS 66.6KW DC/66.6KW AC.SCOPE OF WORK INCLUDES (180) HYUNDAI SOLAR MODULES WITH (90) P850 OPTIMIZERS, AND A SE66.6K INVERTER.  PERMIT 1 OF 2 - OTHER PERMIT IS CARPORT INSTALLATION UNDER 19041-20000-21615.$0 PERMIT FEE PER STATE SENATE BILL SB 1222 AND ASSEMBLY BILL AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40442	18041-10000-18621	5151 W HOLLYWOOD BLVD	90027	13	148-5A195  88	5544011021	C2-1D	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.10192	-118.30232	PC FOR Tenant Improvement IN EXISTING RESTAURANT FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA  1678 SQ.FTSCOPE OF WORK INCLUDES NEW CIRCUITS, RECEPTACLES AND LIGHTS. B#18016-10000-11608	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40443	17041-20001-29371	10432 N SEPULVEDA BLVD	91345	7	207B145   734	2649019009	C2-1, P-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	PIN	34.26038748	-118.46690796	9.20.2017 - Plan check for changes to approved set. Provide new circuit for unit exit signs. Provide secondary set of dedicated switches for dining room lights in dining room (primary control by Grafik Eye system in office). Separate inverter circuit so it is not run with normal power. Only changes.======Plan check for Title 24 only in Tenant improvement to (e) resturant. Total area: 1,825 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40444	17041-10000-02605	1450 S MIRASOL ST	90023	14	117A227    20	5192004012	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.01619	-118.19935	PC for title 24. Indoor + Outdoor. Remove HID fixtures and replace with new LED fixtures. Area: 105,250.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40445	19041-10000-38065	5201 N VAN NUYS BLVD	91401	4	172-5A151 218	2249006020	(T)(Q)C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1288.02	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM			PC Info Complete	11/14/2019 12:00:00 AM	ADDRESS	34.16507	-118.44891	ENERGY PC ONLY FOR A TI TO EXISTING SPACE. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLE, LIGHTING AND CONTROLS.  TOTAL AFFECTED AREA IS 21313SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40446	18041-10000-16474	15952 W STRATHERN ST	91406	6	189B141    75	2206006009	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.21559	-118.48114	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40447	11041-10000-16789	11373 W RIVERSIDE DR	91602	4	168B173   525	2353028071	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.15732	-118.37836	T.I.  Existing 7-Eleven.  Remodel of light fixtures in the retail area only.  Replacing the existing fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40448	19041-20001-49364	3820 W ADAMS BLVD	90018	10	123B185   684	5051003003	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.03241	-118.32672	EXPEDITE FEES.PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS. 39 MODULES AND MICROINVERTERS. TOTAL SYSTEM SIZE IS 19.14KWDC AND 18.27KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40449	18041-10000-04680	630 E BROOKS AVE	90291	11	108B145   133	4239012016	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	33.99571	-118.46798	PC FOR NEW ESS (TESLA POWER WALL 2)SCOPE INCLUDES NEW ESS SYSTEM WITH NEW LOAD CENTER AND RELOCATION OF EXISTING CIRCUITS.NOTE: EXISTING PV SYSTEM IN THIS PROJECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40450	18041-10000-45929	815 E 1ST ST	90012	14	129A215    73	5173012033	C2-1-CDO-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.04872	-118.23467	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40451	17041-20000-06731	1217 S OCEAN FRONT WALK	90291	11	108A143   383	4226005004	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Closed	07/27/2021 12:00:00 AM	ADDRESS	33.98864	-118.47504	Plan check for power only. New 2,000A service and distribution for apartment hotel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40452	17041-10000-04021	3550 W WILSHIRE BLVD	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.06157	-118.30226	PC for power for an existing emergency system.  Scope includes removing an emergency generator and redistributing loads to another existing emergency generator.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40453	17041-10001-42742	981 S ELDEN AVE 1-16	90006	1	129B197   158	5076003014	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Apartment			11/16/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Closed	06/04/2019 12:00:00 AM	ADDRESS	34.05302	-118.28797	Change to approved set by modifying the single line diagram with all distribution board combining into one new meter board. All changes under delta-1 only.(((PC FOR POWER ONLY FOR AN APARTMENT BUILDING. SCOPE INCLUDES ADDING A NEW 600A 120/240V SERVICE/DISTRIBUTION BOARD, TWO NEW 100A SUBPANELS, AND ONE NEW 200A DISTRIBUTION SECTION. CONVERT TWO (2) BEDRM UNITS INTO TWO (1) BEDRM UNITS AND TWO SINGLE RM UNITS WITHIN AN EXIST APT BLDG. B#17016-20000-17576)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40454	17041-10000-38438	1130 W C ST	90744	15	027B201    90	7417008038	M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	33.77182	-118.27581	INSTALLATION OF TWO 125 HP PUMP MOTORS AT AN INDUSTRIAL FACILITY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40455	18041-20001-27307	5959 N CANOGA AVE	91367	3	177B105    88	2146006018	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM			PC Approved	03/08/2019 12:00:00 AM	ADDRESS	34.17875	-118.59772	Plan check for lost of approved set of plan, Plan check for Title 24 only Tenant Improvement  of existing Bank of America. Total area: 7,683 sq ft. BULIDING PERMIT: 18016-10000-23241Note: Electrical Permit pulled under application number: 18041-20000-38999 Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40456	13041-10000-21996	4081 W 8TH ST	90005	4	132B189   531	5092011025	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.05822	-118.3171	PV1 ROOF-MOUNTED INSTALLATION . SYSTEM SIZED AT 5.25 KW. (21) MODULES : HANWHA HSL 60 245W(21) MICROINVERTER: M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40457	12041-10000-30784	12751 W MILLENNIUM B	90094	11	102B161  1235	4211033050	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			12/21/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	PLAN CHECK POWER AND ENERGY FOR BUILDING B. FIRST LEVEL RETAIL WITH 3 STORY OF 120 UNITS RESIDENTIAL BUILDING ON TOP OF COMMON SUBTERRANEAN PARKING GARAGE. TWO SERVICE SUPPLYING BUILDING. SITE LOCATED IN METHANE ZONE. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40458	14041-20000-25309	6904 N TUJUNGA AVE	91605	2	183B173   176	2319005035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.19577	-118.37887	TI TO EXISTING OFFICE BUILDING. 1ST AND 2ND FLOORS. NEW CIRCUITS FOR WORKSTATIONS AND DISTRIBUTION EQUIPMENT. PLAN CHECK FOR POWER AND ENERGY. PER BUILDING SUBMITTAL, PLAN CHECK ACCORDING TO 2013 BUILDING EFFICIENCY STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40459	12041-10000-29502	757 E PICO BLVD	90021	14	123A211    92	5132012018	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/07/2012 12:00:00 AM			PC Approved	12/07/2012 12:00:00 AM	ADDRESS	34.03204	-118.25205	MERGE 3 RETAIL STORES TO ONE RETAIL STORE. 1 STORY. LESS THAN 400A. T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40460	10041-20000-06044	3047 S ROBERTSON BLVD	90034	5	123B169   910	4311030019	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	04/02/2010 12:00:00 AM		Permit Finaled	06/30/2010 12:00:00 AM	ADDRESS	34.03227	-118.39057	New Fire Alarm system for Preschool	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40461	12041-10000-01993	2669 N GRIFFIN AVE	90031	1	139-5A223  23	5206005018	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			01/26/2012 12:00:00 AM	04/09/2012 12:00:00 AM		Permit Closed	06/09/2015 12:00:00 AM	ADDRESS	34.07847	-118.21203	PLAN CHECK FOR NEW 141.6KW ROOF MOUNTED/CANOPY GROUND  MOUNTED PHOTOVOLTAIC SYSTEM, NEW 600A SERVICE, AND ELECTRICAL VEHICLE CHARGING STATION FOR EXISTING APARTMENT BUILDING.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
40462	15041-10001-13118	9313 W BOLTON ROAD	90034	5	126B169    68	4309012014	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM			PC Approved	06/23/2015 12:00:00 AM	ADDRESS	34.04514	-118.39248	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: KYOCERA KU2606XPA(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40463	16041-20000-37632	726 E 78TH ST 1/2	90001	9	099B205   515	6023031024	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	33.96834	-118.26203	PV1.  Install 4.2 kW AC roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40464	12041-10000-11479	1300 W 24TH ST	90007	8	123B197   573	5055003026	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM			PC Approved	05/18/2012 12:00:00 AM	ADDRESS	34.03423	-118.28913	T.I./ FOOD MARKET,  Title 24 & Emerg Ltg plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40465	09041-10002-17090	5557 E VALLEY BLVD BUILDING-330	90032	14	139-5A237  59	5220032003	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM			PC Approved	03/08/2010 12:00:00 AM	ADDRESS	34.07723	-118.16241	PLAN CHECK FOR REVISION TO APPROVED PLANS. CHANGES TO EMERGENCY LIGHTING IN CORRIDOR AND AND LIGHTING CONTROL SYSTEM FROM LC&D TO CRESTON ELECTRONICS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40466	19041-20000-41507	16341 W LONDELIUS ST	91343	12	195B137   710	2688037006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.22942	-118.4889	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (23) MODULES, (23)OPTIMIZERS, (1)6KW INVETER. TOTAL SYSTEM SIZE IS 6KWAC, 7.7KWDC, AND 7.08KW CEC-AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40467	16041-10000-16966	1782 N ORANGE DR	90028	13	150B181   645	5548004010	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM			Corrections Issued	05/13/2016 12:00:00 AM	ADDRESS	34.10395	-118.34162	T-24, CONSTRUCT 2ND FLOOR ADDITION TO EXISTING 1-STORY BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 5060	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40468	14041-20000-34334	15230 W VANOWEN ST	91405	6	180B145    39	2235004009	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.19371	-118.46506	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING PANEL, BRANCH CIRCUITS AND LIGHTING FIXTURES.  PLAN CHECK FOR TITLE-24 AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40469	12041-10000-04127	1054-1070 N WESTERN AVE	90029	13	144B193   885	5536023018	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM			Corrections Issued	06/20/2012 12:00:00 AM	ADDRESS	34.08975	-118.30895	PLAN CHECK. POWER AND ENERGY FOR NEW 1 STORY GROCERY STORE. NEW 1200A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40470	18041-10000-08117	20000 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.27519	-118.57042	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A MEDICAL OFFICE SPACE. TENANT IMPROVEMENT FOR EXISTING SHELL BUIDING WHICH INCLUDES 3 FLOORS(NON OSHPD). SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 50,000 SQ.PLAN CHECKER TO VERIFY FEES FT. B#18016-10000-08339	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40471	15041-20001-00800	17044 W OAK VIEW DR	91436	5	165B133   136	2292001040	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.15106	-118.50535	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted array on a SFD. Interconnect with a 400A MSP (?).System size: 16.4kW (11.4+5). Grounded system. 56  327W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40472	18041-10000-41643	4400 W SLAUSON AVE	90043	8	108B181   331	4019004040	C1.5-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.98869	-118.35193	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40473	12041-10000-29342	10847 N ETIWANDA AVE	91326	12	207B125    59	2715005054	RE11-1	North Valley	Northridge	Northridge East		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.26776	-118.53194	PV1 8.175KW ROOF-MOUNT SUNPOWER. POSITIVE GROUND 1 STORY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40474	12041-20000-02012	5802 W WILLOUGHBY AVE	90038	13	144B189  1034	5534029003	[Q]C2-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.08696	-118.32253	Zero fee plan check application due to department error. original permit # 100412000011514 plans expired and customer submitted new application and paid the required fee, when customer had the old permit number the plan checker copied the old number from the customer which was given to him by the original plan ckecker was wrong it belongs to different job and completely different address. therefore fee was paid and I generated this application with zero fee to continue plan check and grant the fee paid to this application .  (Elie Maalouf  818-374 4343)  application was wrongly writing on the plans was               110412000111514	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40475	19041-10000-34118	11307 S HINDRY AVE	90045	11	087B173   125	4129037008	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	33.93166	-118.37253	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40476	10041-10000-01445	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	12/21/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	TI IN KODAK THEATRE. PARTIAL REMODEL OF LEVEL 1 AND ADDITION OF NEW LEVEL 0. PLAN CHECK POWER AND ENERGY. ADDITION  TWO TRANSFORMERS (500 & 750KVA - 4160V:480V), DISTRIBUTION PANELS, AND WORK ON EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40477	18041-20000-33845	20607 W CHESTNUT CIR #285	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.29259	-118.58378	pv1install roof mounted pv system sized 2.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40478	13041-20001-25681	11835 N EDDLESTON DR	91326	12	216B125   181	2870023041	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.2883	-118.53449	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12.54KW. 44 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40479	18041-10000-03957	5832 S VERMONT AVE	90044	9	108B197  1460	6004001031	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			PC Info Complete	04/24/2018 12:00:00 AM	ADDRESS	33.98854	-118.29128	PC for T24 only. Application fees covered under 18041-10000-03953. B# 18016-70000-02971.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40480	18041-10000-13965	22359 W CANTARA ST	91304	3	189B101    28	2012024010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.21804	-118.61442	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.19KWdc / 3.0KWac.(11)MODULES-LONGI SOLAR(11)OPTIMIZERS-SOLAREDGE OPTIMIZERS(1)INVERTERS-SOLAREDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40481	10041-10000-22103	310 W WASHINGTON BLVD BLDG #8	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	04/15/2011 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 5 UNIT TOWN HOME WITH LEASING OFFICE ON GROUND FLOOR.   (BUILDING #8)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40482	18041-20000-05802	20141 W WELLS DR	91364	3	171B113   458	2166009006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	09/15/2018 12:00:00 AM	ADDRESS	34.16189	-118.57156	PV1.  Install 14.7 kW roof mounted grid tied PV system.  (50) modules with microinverters.$24.91 permit fee per State Senate Bill SB 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40483	13041-10000-32764	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.0446	-118.21143	Fire alarm system installation for a commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40484	15041-10000-19749	5026 W ROSEWOOD AVE 1-22	90004	4	141B189  1099	5522021027	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.07919	-118.31445	NEW FIRE ALARM SYSTEM FOR 22 UNIT APARTMENT COMPLEX. 87 DEVICES AND 1 NEW FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40485	19041-10000-13718	6725 W SUNSET BLVD STE 470	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.09814	-118.33717	Energy PC for TI-Suite470 (change of use). area scope of work 4039SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40486	11041-10000-20144	4355 W PICO BLVD	90019	10	129B185  1024	5082016023	C4-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM			PC Approved	09/21/2011 12:00:00 AM	ADDRESS	34.04826	-118.32967	T.I. to an existing commercial space.  PLAN CHECK ONLY for energy (Tailored Method).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40487	14041-20000-21529	11201 N CHALON ROAD TEMP	90049	5	141B145   149	4369009007	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.08239	-118.46048	TEMP POWER FOR JOB SITE CONSTRUCTION. 600A 480V SERVICE. NEW TRANSFORMER AND STUBS FOR TRAILER CONNECTIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40488	13041-10000-15019	18131 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.16596	-118.52824	see contact for more info.pc for power and energy. NEW 4-STORY AND 2-LEVEL SUBT. GARAGE 196893SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40489	11041-20000-12011	10880 W WILSHIRE BLVD 960	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	06/10/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.05885	-118.44283	TI IMPROVEMENT TO AN EXISTING 25-STORY OFFICE BUILDING.  T-24 PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40490	16041-30000-42235	601 S FIGUEROA ST 35th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is the elevator lobby and corridor of the 35th floor of a high-rise commercial building. Project scope is a tenent improvement. Total lighting area = 1,605 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40491	18041-10000-04265	21344 W DEERING CT	91304	3	189B105   116	2109001032	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Issued	02/06/2018 12:00:00 AM	ADDRESS	34.21662	-118.5966	PC for T24 only for replacement of outdoor metal halide with new LED fixtures.Total of 8950sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40492	17041-20000-15858	6600 N TOPANGA CANYON BLVD #2093	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is a tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,031 sq. ft.Note: Building application has been generated under 17016-30000-02742.  Also low voltage for lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40493	14041-10000-13040	726 E 12TH ST # 104	90021	14	123A211    22	5132012060	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.03314	-118.25248	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLOURESCENT FIXTURES, TOTAL AREA 689 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40494	15041-10000-02750	6935 W FOOTHILL BLVD Front	91042	7	202-5A201 497	2568016058	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.24798	-118.28291	Title 24 plan check only.  Total area = 3992 sq. ft.Remove HID light fixtures and replace with new LED fixtures.Plan check covers front and back building.Permit covers front building only.Permit for back building is 15041-10000-02755	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40495	13041-10000-08011	457 N FAIRFAX AVE	90048	5	141B177  1210	5527031015	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			Corrections Issued	03/28/2013 12:00:00 AM	PIN	34.07986856	-118.361786	RENOVATION OF EXISTING RETAIL SPACE. SMALL OCCUPANT LOAD. PC FOR ENERGY ONLY. TOTAL AREA 753 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40496	16041-20000-05917	20455 W ROBERT PL	91364	3	169-5A111 152	2174020003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.15654	-118.57895	PV1.  Install 8.4 kW DC roof-mounted PV system.  Central inverter standard plan.  (30) SolarWorld SW 280 modules with (1) SE7600A-US transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40497	18041-10000-40438	4228 S WESTERN AVE	90062	8	114B193  1128	5021009013	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Approved	10/23/2018 12:00:00 AM	ADDRESS	34.00651	-118.30876	TENANT IMPROVEMENT OF EXISTING RETAIL STORE. INSTALL NEW LIGHTS. T-24 ENERGY ONLY. 5580SQR FT.BUILDING PERMIT: 18016-30000-18477	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40498	13041-20000-36028	15111 W NORDHOFF ST PV1	91343	7	198B145   375	2656022007	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Expired	02/02/2016 12:00:00 AM	ADDRESS	34.23565	-118.46139	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 6.0KWAC. PERMIT HAS ALREADY BEEN PULLED AND ZONING HAS BEEN CLEARED ON APPLICATION#: 13041-20000-35714	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40499	12041-10000-24660	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	33.94286	-118.39982	TI in a retail store in CNN Newstand @ LAX terminal 7. EPC is for T24. EPC is for T24. (space 7L)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40500	11041-10000-25036	5333 N CAHUENGA BLVD	91601	4	171B177   215	2416027057	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.16807	-118.36179	New 16.1 KW, roof-mounted, photovoltaic system for an existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40501	19041-10000-18239	3643 S EMPIRE DR 1-8	90034	5	120B165   769	4313003009	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	12/01/2021 12:00:00 AM	ADDRESS	34.02527	-118.40381	Plan check for a  fire alarm system located in a 5-story 8-unit apartment building. Scope includes (1) fire alarm panel , (1) power supply and (47) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40502	15041-10000-42012	721 S BONNIE BRAE ST	90057	1	132A203   223	5142003014	R4-2	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Apartment			12/14/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.05484	-118.27507	INSTALL NEW FA SYSTEM FOR AN EXISTING 3-STORY, 28 UNITS  APARTMENT BUILDING WITH 70 FA DEVICES, ONE FA PANEL AND ONE ANNUNCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40503	16041-10000-03175	3330 W FLORENCE AVE	90043	8	102B185   822	4012016019	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	33.97436	-118.33051	T-24, TI TO AN (E) RETAIL BUILDING, 7 ELEVEN. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3007.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40504	10041-10000-07171	1411 N DETROIT ST 1-23	90046	4	147B181   853	5548018042	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Public Safety Only			04/20/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.0966	-118.34544	INSTALL A NEW FIRE LIFE SAFETY SYSTEM IN 23 UNIT APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40505	19041-20000-08877	1143 S GLENVILLE DR	90035	5	132A167   188	4330035009	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	05/16/2021 12:00:00 AM	ADDRESS	34.05586	-118.39307	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW 5 STORY 13 UNIT LOW RISE APARTMENT BUILDING, SCOPE OF WORK INCLUDES 1 FACP, AND 74 FIRE ALARM DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40506	19041-10000-36287	7217 N GEYSER AVE	91335	3	183B121    48	2118025006	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.20173	-118.54275	REMOVE HID FIXTURES AND REPLACE WITH NE LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40507	16041-30000-04962	4221 W WILSHIRE BLVD #270, 275	90010	4	132B189    20	5504001014	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.06194	-118.32113	Title 24 plan check only.  Total area = 1,850 sq. ft.    T.I. to existing commercial office highrise.  Combining two spaces into one.  Subpanels to remain existing with new lighting and receptacle loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40508	16041-20001-34959	3825 N MISSION ROAD	90031	1	136-5A227  10	5211011031	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM			PC Approved	07/09/2019 12:00:00 AM	ADDRESS	34.07009	-118.19958	"Revisions to approved set of plans.  Removal of methane mitigation measures (site is not designated as methane or methane buffer zone), HVAC system redesign, and miscellaneous power changes.  (((New 2000 amp service for a three story classroom building B occupancy.  Reconnect existing distribution ""MS"" to new board ""MSN."" Plan check for power and energy.  Total square footage - 7256 sq ft.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40509	16041-10000-39889	8000 N WHEATLAND AVE	91352	2	189B177   973	2407015***	M1-1, MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.21656	-118.36166	PC FOR T24 ONLY. REMOVE E HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 64500 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40510	13041-10000-29537	12790 N ADELPHIA AVE	91340	7	222B157   495	2513012029	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.3027	-118.42622	PV1.  Install 7 kW DC roof-mounted solar array, interconnect with main service panel.  Inverter: Fronius IG 5100 Neg. 28 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40511	19041-10000-44679	860 S BROADWAY	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.04235	-118.2558	Energy plan check for a T.I. Scope includes new lighting and equipment with a total lighting area of 881-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40512	14041-10000-21402	14402 W CALIFA ST #8	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40513	16041-10000-23246	1553 S CURSON AVE	90019	10	129B177  1328	5069020022	R2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.04682	-118.36102	PV1, INSTALL NEW 2650 W DC ROOF-MOUNTED SOLAR ARRAY ON  A SINGLE FAMILY HOUSE.(10) MODULES:CANADIAN SOLAR CS6P-265P(1) INVERTER: SOLARDGE TECHNOLOGIES SE3000(240)W/-ER-US OR A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40514	15041-20001-08753	7208 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.24848	-118.28894	Plan check for power and energy. Project scope is a tenant improvement to a new commercial space (first time tenant; approved for counter plan check by E.M.). Total lighting area = 1,092 sq. ft. This is a supplemental application for the power plan check. Permit has been pulled under the master application.*****Previous Work Description*****Plan check for Title 24 only. Project scope is a tenant improvement to a new commercial space (first time tenant; approved for counter plan check by E.M.). Total lighting area = 1,092 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40515	14041-10000-31863	451 S MAIN ST	90013	14	129A211   281	5149022***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.04711	-118.24844	Title 24 plan check only.  Total area = 4,550 sq. ft.T.I. to existing hotel highrise building.  Installation of new lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40516	15041-10000-31815	11900 W OLYMPIC BLVD 810	90064	11	123B149   541	4259024003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.03252	-118.45186	T-24, TI TO AN (E) HIGH RISE OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. EXISTING CIRCUITS 43 UNITS. PC FOR ENERGY ONLY. TOTAL SQ. FT. 1521.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40517	10041-20000-07138	16830 W VENTURA BLVD UNIT 200	91436	5	168B133   198	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.15886	-118.50032	TI TO OFFICES/ CLASSROOMS FOR PEPPERDINE UNIVERSITY. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40518	16041-20000-08602	12527 N SAN FERNANDO ROAD	91342	7	219B149   403	2604033002	C2-1, R1-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.29765	-118.45762	PLANCHECK FOR POWER. SERVICE UPGRADE FROM 400 AMPS TO 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40519	09041-30005-08041	241 S DETROIT ST	90036	5	135B181    68	5513021028	RD6-1	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM			PC Approved	04/01/2010 12:00:00 AM	ADDRESS	34.06971	-118.34525	Supplemental is for changes to previously approved set.  Delta 9 revisions changes revise panel schedule and circuits on floor plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40520	16041-20000-21952	7940 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21523	-118.53476	PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40521	10041-20000-09265	2220 S AVENUE OF THE STARS #1104	90067	5	129B161    53	4329003***	R4-1L-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Apartment			05/18/2010 12:00:00 AM			Plans on Hold	06/02/2010 12:00:00 AM	ADDRESS	34.05241	-118.40939	Plan check power and energy per owner's request for dwelling unit in an existing high rise residential building.customer does not want plan check because of the waiting time ( Plan check was not originally required)customer withdrew the application 5/18/10	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40522	17041-20001-06086	8372 N TOPANGA CANYON BLVD	91304	3	192B101   469	2779043035	(Q)C1.5-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.22187	-118.60576	Plan check for power per inspector correction notice.  Installing meter section serving (3) new 200A meter sockets.  Installing (2) meter sockets on adjacent service equipment.  ((INSTALLING (6) 200A METERS.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40523	11041-20001-10632	12301 W WILSHIRE BLVD 600	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM			PC Approved	06/28/2011 12:00:00 AM	PIN	34.04277409	-118.46969044	TI IN AN EXISTING OFFICE. EPC IS FOR T24. (PERMIT WAS ISSUED UNDER# 11041-30000-10632)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40524	12041-10000-28962	905 E 2ND ST	90012	14	129A215   180	5163004006	(T)(Q)C2-2D	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			12/03/2012 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.04729	-118.23499	5-stories mixed use building over 2 levels basement; 320-Apts;	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40525	18041-10000-41993	5525 W SUNSET BLVD	90028	13	147A193   102	5544023023	C2-1	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.09826	-118.31015	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40526	11041-20000-09251	127 S SAN VICENTE BLVD Bulletin-64CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin # 64CS.  Relocate electrical equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40527	14041-20000-12484	10930 N BELMAR AVE	91326	12	210B117   295	2708007005	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.2689	-118.55773	Roof mounted PV system, with system size 10.71KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40528	12041-20000-10468	1620 N AMALFI DR	90272	11	132B133    73	4425034017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.06061	-118.50216	solar system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40529	17041-20000-29708	12265 N LIMA WAY	91342	7	219B149   937	2611046029		North Valley			YES	1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Issued	08/21/2017 12:00:00 AM	ADDRESS	34.29409	-118.45632	pv1install roof mounted pv system sized 3kw interconnected with msp.  standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40530	13041-10000-27633	11831 S JUNIETTE ST	90230	11	105B165   207	4220003043	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	PIN	33.98657022	-118.40307733	PV1 ROOF-MOUNTED SOLAR INSTALLATION OF 3.024 KW AC SYSTEM , ON MICROINVERTER STANDARD PLAN IN SINGLE STORY HOME. (14) MODULES : ET-P660255WB(14) ENPHASE-M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40531	13041-10000-11865	116 W 4TH ST	90013	14	129A211    63	5149023013	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.04844	-118.24799	T.I. FOR 4TH STREET BASEMENT BAR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40532	18041-10000-11921	1704 S HOOPER AVE	90021	14	120A213   220	5129009014	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.02303	-118.24498	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR WARE HOUSE. 10135 SQFT. ELECTRICAL WORK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40533	16041-10001-41397	14878 W NURMI ST	91342	7	222B149   925	2506009003	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.30236	-118.45683	01/03/17Changes to an approved set of plans. Changes include relocating solar modules on roof-layout. Note: Permit is paid under PCIS#16041-10000-41397	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40534	16041-10000-09975	409 W ELBERON AVE #4	90731	15	021B197   746	7448024***	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	Apartment			03/22/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Expired	04/24/2018 12:00:00 AM	ADDRESS	33.75059	-118.28801	Solar installation on Condominium #4.    (18) KD255GX-LFB3    (1) PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40535	10041-30000-04449	10880 W WILSHIRE BLVD #2100	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	06/15/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check T-24 energy (general/emergency) lighting for suite 2100 in a high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40536	16041-20001-07504	970 N MONUMENT ST	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.04646	-118.52393	05-06-16 Change to approved set of plans. Changes include lighting fixtures manufacturer, removed daylight sensors and removed dimmers in the treatment room. {{{{{Plan check for energy only. TI for beauty salon. New lighting. 1,185sqft.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40537	16041-10000-35294	1141 W 2ND ST BUILD. L&J	90012	1	133-5A209 224	5152009901	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Issued	12/06/2016 12:00:00 AM	ADDRESS	34.0588	-118.25625	NEW PV SYSTEM 30KW ROOF MOUNTED.  (1) 27.6 KW INVERTER,  (100) MODULES.  PROJECT LOCATED ON METHANE ZONE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40538	13041-10000-14615	6235 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	08/01/2013 12:00:00 AM	ADDRESS	34.18398	-118.60617	FA addressable for citibank. 49 devices and 1 panel and 1 annuciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40539	18041-20004-48715	8600 W LA TUNA CANYON ROAD	91352	7	198B189   116	2401028***	A1-1XL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.23699	-118.3204	CHANGES TO APPROVED SET DELTA 3 ONLY. 100A FUSED AC DISCONNECT WITH J-CLASS TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40540	19041-20001-14624	5119 N BEEMAN AVE	91607	2	171B161   724	2357004017	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.16359	-118.40751	Plan check of contractor design-build plan set.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40541	16041-10001-34411	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM			Reviewed by Supervisor	10/04/2016 12:00:00 AM	ADDRESS	34.25052	-118.51258	EXPEDITE PER APPLICANT REQUEST. (((((PV1. AN ADDITION TO AN ON EXISTING RESIDENTIAL PV SYSTEM. ADDING 13.8KWac TO AN EXISTING SOLAR SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING SOLAR ARRAYS IS 20.8KWac.(60)MODULES-REC SOLAR: REC275TP(1)INVERTER-SOLAREDGE 10000A-US(1)INVERTER-SOLAREDGE SE3800 ER-US(1)SUBPANEL-125A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40542	14041-10000-10357	520 S VIRGIL AVE	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.06457	-118.28687	Plan check for power and energy for existing medical office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40543	13041-10000-21154	12652 W VILLAGE LANE bldg #10	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #10	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40544	16041-10001-40389	5200 W CENTURY BLVD	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	33.94516	-118.37049	Change to approved set by updating the control system and removing some lighting fixture on the floor plan. All changes under delta-2 only.(((FULL PC FOR POWER AND ENERGY. CHANGE OF USE, FROM AN OFFICE TO GYM WITHIN AN EXISTING OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND CIRCUITS. A-OCCUPANT LOAD >100.TOTAL AFFECTED AREA IS 5060 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40545	19041-10000-32470	17508 W ROMAR ST	91325	12	204B129   345	2734016010	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.25468	-118.51604	PV-1, system size is 8.10kw. 27 modules with p320 optimizers. 1 7600h inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40546	16041-20000-30556	21001 W SATICOY ST	91304	3	186B109   186	2109024020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.20845	-118.5909	Plan check for roof-mounted solar pv system. Interconnect with a 125A MSP. 6kW ungrounded system. Each module has a 300W power optimizer. (18) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40547	10041-10000-08123	3670 S TROUSDALE PKWY	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM			PC Info Complete	05/28/2010 12:00:00 AM	ADDRESS	34.01868	-118.28606	Plan check only Delta 2 revision to approved plans. Plan check T-24 Energy (general/emergency) lighting for office spaces TI in Bridge Hall (Suite #205 & 300) at USC.  New application under #10041-20000-10154	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40548	12041-20000-28919	9525 N OWENSMOUTH AVE	91311	12	201B105   247	2746016032	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.24353	-118.60253	New upgraded 3000 amp servicej, 34.5kv transformer, and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40549	13041-10000-26218	100 UNIVERSAL CITY PZ stage  #5	0	4	162B177	2424044015	C2-1, PB-1					1437.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM				replacing high bay luminaires -supplied from existing ckts and lighting area ctrls  for shut-off ctrl;EMERGENCY LUMINAIRES REMAINED THE SAME PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40550	10041-10000-22331	540 S SANTA FE AVE	90013	14	126A217    15	5164004***		Central				2060.50	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.04042	-118.23057	New 46,200 sf - 2 story concrete tilt up office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40551	11041-10000-26415	6709 N GREENBUSH AVE	91401	2	180B157   249	2329012010	R1-1, RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.19233	-118.42593	Plan check 10.34KW roof mounted photovoltaic system single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40552	16041-10000-31553	5675 W OLYMPIC BLVD	90036	4	132B177   701	5089026035	[Q]R3-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.05755	-118.35325	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING REHAB CENTER. SCOPE INCLUDES 123 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40553	16041-10001-20534	400 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	12/15/2017 12:00:00 AM	ADDRESS	34.04446	-118.25616	PC FOR REVISON TO APPROVED SET. CHNGES INCLUDES NEW CORRIDOR SPACE PER DWP  WITH NEW LIGHTS AND CONTROLS AND REVISIONS TO T-24 FORMS. Plan check only********************************Previous Scope of Work****************************Core and shell with service upgrade to 2000A.  New house panel and conduit for three future tenants.  Change of use from Night Club and Restaurant to Restaurant with future interior and exterior alterations done under separate permits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40554	16041-10000-23560	1404 S TOBERMAN ST	90015	1	127-5A203 343	5135032028	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.04229	-118.2769	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.0KWdc / 6.0KWac.(25)MODULES-SUNIVA OPT280-60-4-1B0(25)MICROINVERTERS-M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40555	19041-10000-26380	8757 N CANOGA AVE	91304	3	195B105   161	2779019014	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.22997	-118.5977	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40556	18041-10001-49145	2117 N AMELIA AVE	90731	15	024B193    82	7442009004	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM			PC Approved	01/14/2019 12:00:00 AM	ADDRESS	33.76397	-118.30269	SUPPLEMENTAL EXPEDITE PER CUSTOMER REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40557	10041-10000-21769	16133 W VENTURA BLVD	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Public Safety Only			11/01/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	34.15675	-118.4847	REPLACEMENT OF EXISTING FIRE WARNING SYSTEM FOR A COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40558	18041-20002-28158	6254 N BEEMAN AVE	91606	2	177B161   177	2332015002	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM			PC Approved	08/03/2018 12:00:00 AM	ADDRESS	34.18458	-118.40724	08/03/2018 Changes to an approved set of plans. AC disconnect has been revised to show that it is non-fusible. *****Previous Work Description*****pv1install roof mounted pv system sized 15.2 KW AC interconnected with msp.(55) LG 300W modules(55) p300 optimizers(2) solaredge 7.6KW inverters	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40559	14041-20000-28601	8120 S WINSFORD AVE	90045	11	099B169  1130	4105027012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	33.96459	-118.38112	PV1Central/String inverter standard plan. Rooftop solar array. System size: 7.4kW.(1) 3.8kW and (1) 3.6kW transformerless inverters(26) SunPower E20/327 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40560	15041-10000-15836	20943 W SATICOY ST	91304	3	186B109   218	2109023003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.20845	-118.58994	PV1 INSTALL 5.232 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES:SUNPOWER SPR327NE-WHT-D(1) INVERTER ABB PVI-5000-TL-OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40561	13041-10000-09502	200 N ARNO WAY	90272	11	126B121   584	4415029004	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Expired	05/07/2015 12:00:00 AM	ADDRESS	34.04019	-118.54394	PV1 SINGLE FAMILY DWELLING. 9kW ROOF MOUNT SOLAR SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40562	18041-10000-47128	1201 S GRAMERCY PL	90019	10	129B193   917	5081027021	RE9-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.04914	-118.31328	PV1. INSTALL 9.76 KW DC / 7.6 KWAC  SYSTEM SIZE WITH 32 MODULES (Q.PEAK-G4.1/SC305), INCLUDING (1) INVERTER (solivia 7.6 TL)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40563	15041-10002-34205	1369 W PLAZA DEL AMO	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.82101	-118.30079	CHANGE TO APPROVED SET OF PLANS. PROVIDE PERFORMANCE METER AND FUSED DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40564	13041-10000-28796	12055 N WOODLEY AVE	91344	12	216B137   198	2605008062	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.28912	-118.48729	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A 1-STORY HOME. INTERCONNECTING WITH (E) 200A MAIN SERVICE. SYSTEM IS XFORMERLESS, WITH (31) MODULES: TRINA SOLAR #TSM-250PA05.18(1) SOLAREDGE #SE6000A-US(31) SOLAREDGE OPTIMIZERS: POWERBOX, 250W, #OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40565	10041-10000-22266	209 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04915	-118.22655	Solar voltaic system installed on the roof of the building.  Consists of 5 modules, 5 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40566	19041-20000-05265	3084 S MOTOR AVE	90064	5	123B161   498	4316007009	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.03423	-118.41021	TI to expand (E) kitchen.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40567	17041-20003-19840	968 N SOMERA ROAD	90077	5	144B149   325	4369033014	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM			PC Approved	02/05/2018 12:00:00 AM	ADDRESS	34.0879	-118.45678	2/5/2018changes to an approved set of plans.  changes noted delta 3.  changes to reflect field conditions.  this is plan check only.  (((PC for one new Tesla Powerwall2 connected to existing load center and PV systen. PV permit for existing solar system under 17041-90000-16233.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40568	10041-20000-02397	15240 W SUNSET BLVD	90272	11	129B125   771	4412002018	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	04/20/2010 12:00:00 AM	ADDRESS	34.04647	-118.52502	Tenant improvement - remodeling (E) existing bank. Title 24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40569	13041-10001-03789	18842 W EDLEEN DR	91356	3	168B121   274	2176025008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			Corrections Issued	07/05/2013 12:00:00 AM	ADDRESS	34.15675	-118.54372	Supplemental: Change of module from REC 245 PE to REC 250 PE.  Original description: PV1 SINGLE STORY HOUSE 17 MODULES.  3.672 KW SYSTEM POWER {MODULES: REC245PE} {MICROINVERTER: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40570	18041-10000-30624	8450 W FOOTHILL BLVD	91040	7	204B189    29	2560005008	C2-1VL, R3-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.25953	-118.31728	REMOVE OURDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40571	18041-20000-11203	16444 W ROSCOE BLVD	91406	6	189B137     4	2205003906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21987	-118.49574	PLANCHECK FOR POWER. TEMPORARY POWER FOR AIRPLANE HANGAR. 600 AMP SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40572	15041-20000-15552	5018 N MEDINA ROAD	91364	3	168B105   166	2168009021	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.15948	-118.59995	Plan check for PV roof mounted 11.4kW system with 46 modules and 1 inverter (11.42kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40573	15041-20000-32044	20735 W BRYANT ST	91306	3	195B109   396	2780008011	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.2271	-118.58527	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING 26 MODULES TOTA. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40574	15041-10001-14025	7836 W JAYSEEL ST	91040	7	208-5A195 249	2556011039	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.26533	-118.30399	PV1, Install 4.480 kW DC roof-mounted grid-tied solar array, interconnect with service panel. (16)modules: solarworld Plus SW 280 mono black(1) Inverter: Power-one PVI-3.6-OUTD-S-US-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40575	18041-10000-00518	4110 S AVALON BLVD	90011	9	115-5A207 498	5115002013	C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.00879	-118.26507	PC for T24 only for new lighting in two story building. Installing new 400A service with one panel and receptacles, equipment.Total indoor and outdoor area is 8060sqft.B# 17010-20000-03158	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40576	19041-20000-50375	9330 W HILLROSE ST	91040	7	207B185   419	2549014023	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Closed	10/26/2021 12:00:00 AM	ADDRESS	34.26213	-118.33501	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 10.56 KW DC/10.08 KW AC. SCOPE OF WORK CONSISTS OF (32) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40577	14041-10003-14508	1825 N BRONSON AVE	90028	13	150A191   280	5586027006	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.10425	-118.31823	Changes to approved set.  192 new fire alarms.(148) NEW DEVICES.  ONE NEW PANEL / PERMIT WAS PULLED UNDER 14041-10000-14508. PLAN CHECK ONLy (((((((((((((((((((((    addition of 80 new devises.))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40578	15041-10000-21143	7310 N ETON AVE	91303	3	186B105   821	2112024012	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Apartment			07/06/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.20323	-118.59534	Full plan check for a new 7-UNIT 3-STORY apartment over a grade level parking. Main scope includes a 3-phase 4-wire 600-Amp 120/240V service, 4-typical for 8 panels, Total (127) circuits, (6) equipment, and 4201-SQ feet for T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40579	14041-20000-05341	14209 W VENTURA BLVD	91423	4	165B153   352	2265019011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.15006	-118.44243	PLAN CHECK FOR POWER AND ENERGY FOR REMODEL OF EXISTING GUITAR CENTER. TOTAL NEW LOAD EXCEEDS 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40580	14041-20000-14670	401 S GRAND VIEW ST	90057	1	135A203   316	5154036012	R3-1	Central	Westlake			2088.02	Electrical	Electrical	Apartment			06/03/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.06322	-118.27542	New 3-story, 29 unit apartment with basement garage in Methane Zone.  New 1600A service, panels, and circuits.  New lighting in garage and common areas.  Plan check for power and energy.Note: Variance to separate fire alarm plans submitted on 6/3/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40581	19041-10000-08688	3901 S WESTERN AVE	90062	8	117B193  1416	5035017030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.01444	-118.30916	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40582	16041-10000-23137	9235 N SOPHIA AVE	91343	12	198B137   629	2676024020	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.23849	-118.48849	PV1. INSTALLING  6.5KW DC ROOFTOP MOUNTED SOLAR ARRAY ON A SINGLE FAMILY. 25 MODULES  HUUNDAI HIS-S260RG (260W) INCLUDINGMICROINVERTES ENPHASE M215-60-2LL-S22 and COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40583	10041-20002-24242	11055 W CUMPSTON ST	91601	4	174B173  1242	2350003009	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			02/17/2015 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	ADDRESS	34.17012	-118.37213	CHANGES TO APPROVED SET OF PLANS. CHANGE IN NAME OF UNITS. CHANGE TO SERVICE EQUIPMENT. NOT A SINGLE 800A METER STACK. PC FOR CHANGES CLOUDED DELTA 4. RECHECK NEW LOADING AND FAULT CURRENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40584	11041-10000-16921	19658 W HIAWATHA ST	91311	12	204B117    69	2708024020	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	01/11/2012 12:00:00 AM	ADDRESS	34.25914	-118.56207	NEW ROOFTOP  PV SYSTEM FOR A SINGLE FAMILY RESIDENCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40585	14041-20001-14218	13812 W SATICOY ST	91402	6	186B153    43	2214023003	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.20979	-118.43395	Fee for expedite only.*****Roof mounted PV system on commercial building.  PV system size 13KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40586	18041-20000-24480	3815 W AVENUE 43 1-28	90041	14	156A219    57	5473024021	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Apartment			06/29/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	04/12/2021 12:00:00 AM	ADDRESS	34.12326	-118.22379	Plan check for power and energy for 3 story 28 units mixed use building. Service size: 1200A Total area: 16,839 sq ft.  B#17010-20000-01509	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40587	16041-20000-07186	8125 N LAUREL CANYON BLVD	91605	2	189B165    66	2309028005	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Expired	04/02/2018 12:00:00 AM	ADDRESS	34.21846	-118.39672	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.28 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40588	12041-10000-00606	10527 W SANTA MONICA BLVD	90024	5	132B157   928	4326033030	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	PIN	34.05537841	-118.4278607	PLAN CHECK POWER AND ENERGY FOR TWO STORY OFFICE BUIDING. SCOPE OF WORK CHANGE FROM ORIGINAL SUBMITTAL. NEW 200A SERVICE, AC EQUIPMENT, AND BRANCH CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40589	19041-10001-37185	828 N EUBANK AVE	90744	15	030B209   138	7423024031	[Q]MR2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM			PC Approved	12/16/2019 12:00:00 AM	ADDRESS	33.78127	-118.25488	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE REVISING SERVICE FROM UNDERGROUND TO OVERHEAD SERVICE, REVISING FLOOR PLANS TO REFLECT AS BUILT.NOTE: PERMIT FEES ARE PAID UNDER PCIS#19041-10000-37185	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40590	15041-20002-42081	5201 W 20TH ST	90016	10	126B177   953	5063001014	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			04/27/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.04046	-118.35441	Changes to approved set.  Change of interconnetion point from (N) main service panel to (E) apartment unit subpanel.  (((PV1 on multi family dwellings (4 units). Roof mounted installation 3.8kW AC system.(10) Q-Pro BFR-G4 260(10) Power Optimizer SE-P300(1) Inverter SE3800A-US)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40591	13041-10000-36230	11966 W BURTON ST	91605	6	192B165   615	2310003009	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.2206	-118.394	PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY , INTERCONNECT TO (E) 200A MAIN IN A 1-STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE IS 3.25 kW DC. (13)POWER OPTIMIZER:Solaredge Op250-LV-MC4SM-2NA-Z   (13)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40592	19041-10000-38982	4470 E LINCOLN AVE	90041	1	156A221   124	5474025005	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.12283	-118.21916	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE 3.8KWac/4.6KWdc. SCOPE OF WORK IS 15 PANELS (CANDIAN SOLAR CS6K-310MS)  WITH OPTIMZERS (SE P320) , LEADING TO A CENTRAL INVERTER (SE 3800H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40593	18041-10000-08621	1800 E 16TH ST	90021	14	120A213   212	5167003027	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.02311	-118.24125	REMOVE INDOOR-OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40594	14041-20000-26937	5100 N LIBBIT AVE	91436	5	171B137   347	2260017013	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.16217	-118.4878	microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40595	17041-10000-43802	11708 W PICO BLVD	90064	11	123B149   719	4260030018	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.03132	-118.44586	REPLACE HID OUTDOOR FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40596	16041-20000-14836	3460 S BROADWAY	90007	9	118-5A205 368	5122032017	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.01795	-118.27427	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHT FIXTURES ANS REPLACE WITH NEW LED FIXTURES.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 28752.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40597	15041-10001-24722	8935 N ORION AVE	91343	7	195B141   247	2654001053	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.05	Electrical	Electrical	Apartment			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.23288	-118.4722	02/11/16Changes to an approved set of plans. Changes include adding 3 additional low frequency horn strobes. PC Battery calculations and voltage drop calculations. ((((NEW FIRE ALARM FOR A NEW 3-SOTRY APARTMENT BUILDIING. SYSTEM INCLUDE (1) FIRE ALARM PANEL, (2) POWER SUPPLIES, AND  98 DEVICES.  SUBMITTAL PER APPLICANT REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40598	12041-10000-03422	12169 W VENTURA BLVD	91604	2	162B165    51	2367016003	C2-1L, P-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.14353	-118.39748	New Fire alarm system for an existing retail building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40599	16041-30001-25809	601 S FIGUEROA ST 36th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	08-16-2016 Changes to an approved set of plans. Changes include lighting layout changes in pantry area. Plan check for Title 24 only. Project site is the 36th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,720 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40600	15041-10000-06903	707 W WILSHIRE BLVD 44th flr	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	Energy plan check for an office T.I located on the 44th flr of a high rise building. Scope area is 9523-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40601	16041-10000-20551	2733 S MCCONNELL DR	90064	5	126B165   270	4308006008	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.04357	-118.40271	PV1, NEW ROOF SOLAR SYSTEM USING MICROINVERTERS, ENPHASE. (30) MICROINVERTERS, ENPHASE (30) LG ELECTRONICS LG315N1C-G4. ALL MODULES INTERCONNECTED TO A LOAD CENTER, 100 AMP. TOTAL SYSTEM SIZE IS 8.4KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40602	19041-10000-24682	8345 N RESEDA BLVD	91324	12	192B125   562	2785018006	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.22207	-118.53628	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40603	16041-20001-07191	10914 N DARBY AVE	91326	12	210B125   700	2715004019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.26864	-118.53368	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40604	14041-10001-32994	200 WORLD WAY DUTY FREE-SHOP	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Modification of an approved set by reducing load from panel schedule. No new circuit added.(((TENANT IMPROVEMANT ON EXISTING SHELL SPACES 237 & 222 FOR DUTY FREE STORES.  PLAN CHECK FOR ENERGY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40605	19041-10000-48190	5710 W CENTINELA AVE	90045	11	102B169    69	4103005014	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	33.97621	-118.38022	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK IS ADDING 21 EV CHARGERS (LEVEL 2), CONNECTED TO AN EXISTING 600A SWITCHBOARD (120/208 3P,4W).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40606	18041-10000-22042	100 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	PIN	33.94684048	-118.40128468	PLAN CHECK FOR T24 ONLY, RENOVATION OF TERMINAL 1 OPERATIONS LEVEL. NEW CIRCUITS FROM EXISTING PANELBOARDS. AREA: 6,828 SQ. FT((B# 18016-10000-17567 -- RENOVATION OF TERMINAL 1 OPERATIONS LEVEL TO PROVIDE RENOVATED AND EXPANDED LINE MAINTENANCE SPACES INCLUDING OFFICES, LOCKER ROOMS, BREAK ROOM AND STORAGE SPACES. EXPANSION ENCLOSES AND CONDITIONS 3,070 SF OF EXISTING UNCONDITIONED B-OCCUPANCY SPACE UNDER THE EAST SIDE OF THE NORTH CONCOURSE OVERHAND WITH NON-LOAD BEARING PERMITER CMU WALL AND BOLLARD.TOTAL AREA OF WORK: 8,750 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40607	15041-10000-17202	3525 W GLENHURST AVE	90039	13	154-5A207 440	5437008023	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	34.11572	-118.26191	new service  and alterations for existing churchplan chk is for title 24 (less than 50 occupants)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40608	11041-10000-18360	5670 W WILSHIRE BLVD Ste 2350	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.06222	-118.35208	T.I.  Remodel of light fixtures for Suite # 2350.  High rise office building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40609	18041-10001-15294	2681 N CORDELIA ROAD	90049	11	141B133    63	4492025024	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Expired	06/02/2024 12:00:00 AM	ADDRESS	34.08411	-118.5081	THIS IS SUPPLEMENTAL PERMIT AND PLAN CHECK TO REVISION OF PLANS PERMITTED ON-LINE- PV INVERTER INCREASED TO 7.6 KW AC, NEW 100A SUBPANEL, AND 9.8KWH STORAGE BATTERY.(((((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40610	12041-20000-16949	4127 S MARCASEL AVE	90066	11	111B157   588	4233015016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.00033	-118.42264	New roof mounted P.V. system with WITH REDUCTION OF THE SERVICE DISCONNECTING MEANS FROM 200 AMPERE TO 175 AMPERE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40611	12041-10000-26908	633 W 5TH ST	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Approved	11/08/2012 12:00:00 AM	ADDRESS	34.05099	-118.25468	PLAN CHECK FOR T24 ENERGY AND EMERGENCY LIGHTS IN AN OFFICE AND CONFERENCE ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40612	15041-10000-30921	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM			PC Info Complete	10/30/2015 12:00:00 AM	ADDRESS	34.2312	-118.36756	T-24, TI to an exisiting commercial building (Starbucks). Install new lighting, receptacles. PC for energy only. Sq Ft = 1817	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40613	16041-20000-07191	10914 N DARBY AVE	91326	12	210B125   700	2715004019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.26864	-118.53368	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 5 kWac onto the existing 5 kWac, for a total system size of 10 kWac. Addition consists of (1) inverter, (22) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40614	19041-30000-39671	2029 S CENTURY PARK EAST SUITE#1530	90067	5	132B161   697	4319016029		West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY ONLY, TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2366.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40615	13041-20000-07190	6831 W PARK GLENN DR PV-1	90068	4	153B181   590	5549031***	RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.11855	-118.34197	PV-1. 6.615kW DC, one 6kW inverter. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40616	10041-20000-07248	21101 W OXNARD ST	91367	3	177B105    68	2149005044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.17942	-118.59309	T.I. FOR 4,500 SQ FT OF OFFICE SPACE.REMOVE EXISTING TENANT IMPROVEMENTS. This plan check was for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40617	12041-20000-23847	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM			PC Approved	10/09/2012 12:00:00 AM	ADDRESS	34.06338	-118.20434	Title 24 energy only for an office remodel. 1039 square feet. (Suite 203 and 216)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40618	12041-10000-15440	1803 N CAHUENGA BLVD	90028	4	150A187   328	5546001400	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.10418	-118.33009	TENANT IMPROVEMENT PROJECT FOR NEW PANDA EXPRESS RESTAURANT; NEW STOREFRONT; DINING , KITCHEN, INTERIOR FINISHES, TYPE I HOOD; ADA COMPLIED RESTROOMFULL PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40619	18041-10000-33125	7660 N GLORIA AVE	91406	6	186B141    17	2206010022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM			PC Info Complete	08/29/2018 12:00:00 AM	ADDRESS	34.21008	-118.47917	Energy plan check for a commercial storage building. Scope includes new lighting and equipment with a total area of 13,374-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40620	10041-10000-08580	5700 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	06/21/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.06218	-118.35303	TI IN AN EXISTING OFFICE. PLAN CHECK FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40621	14041-10001-04158	2348 N ARTHUR ST	90065	1	151-5A217 202	5456003016	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	34.10984	-118.23236	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 3.75 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3800A-US-ZB-U. (15) Modules: CANADIAN SOLAR CS6P-250PX.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40622	16041-10000-38994	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING OFFICE BUILDING. SCOPE INCLUDES 3 FA PANELS, AND 134 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40623	19041-10000-38466	3580 W WILSHIRE BLVD 6th flr	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.06156	-118.3028	T-24 PLAN CHECK FOR THE RESTROOM AREA OF  AN EXISTING OFFICESPACE LOCATED ON 6TH FLOOR OF A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING, CONTROLS AND EQUIPMENTTOTAL AFFECTED AREA IS 565 SQ.FTOFFICE TI T-24 IS PERMITED UNDER 19041-10000-23438	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40624	17041-20001-09931	4101 S REDWOOD AVE	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM			PC Approved	05/08/2017 12:00:00 AM	ADDRESS	33.99086	-118.44043	Plan check for energy only. New restrooms, Kitchen, and A/C units for commercial office space. New lighting in restrooms. 120sqft. Permit pulled under parent application #17041-90000-09931.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40625	19041-10000-49493	12675 N ENCINITAS AVE	91342	7	219B141    68	2604035014	[Q]CM-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.30035	-118.47459	REPLACE FLOURESCENT TROFFERS WITH NEW LED RETROFIT KITS. REMOVE HID FIXTURES & REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40626	19041-20000-43686	1633 S FAIRFAX AVE	90019	10	129B173  1334	5068020009	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.04657	-118.36797	Plan check for PV roof and Energy Storage system, PV System size: 6.27KW with 19 PV modules and 19 microinverters. (2) Tesla battery PowerWall 2.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40627	15041-20001-15150	10920 N WINNETKA AVE	91311	12	210B113   156	2708021007	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.26855	-118.56904	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40628	12041-20000-04655	19344 W NORDHOFF ST	91324	12	195B117   425	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM			PC Approved	03/06/2012 12:00:00 AM	PIN	34.23468555	-118.55377673	T.I. to existing space for Nail Salon.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40629	19041-20002-30333	13642 N GLADSTONE AVE	91342	7	228B153   396	2503006005	A1-1-K, RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.31994	-118.43984	10-16-2019 Changes to an approved set of plan, Changes include addition of PV meter. All Changes has been clouded. Plan check only. $0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40630	16041-10000-17780	11075 W WRIGHTWOOD LANE	91604	2	159B173   207	2380009005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.1341	-118.37167	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.24KWac.(51)MODULES-LG NEON2 LG310N1C-G4(51)MICROINVERTERS-M250-60LL-X-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40631	14041-10000-14453	1020 S FEDORA ST	90006	1	129B197   286	5078015023	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.0522	-118.29776	NEW FIRE ALARM SYSTEM FOR FEDORA HOTEL, 3 PANELS AND 224 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40632	14041-10000-33606	6351 W CENTURY BLVD	90045	11	093B165   163	4117034901	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM			Reviewed by Supervisor	01/07/2015 12:00:00 AM	ADDRESS	33.94563	-118.39786	Temporary power for construction trailers.  1600A  120/240 3p4w delta service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40633	17041-10000-12846	10250 W SANTA MONICA BLVD # 2910	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""Aldo"" Ste. 2910.  Total area: 1859 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40634	14041-10000-05616	940 S WESTERN AVE	90006	10	132B193  1081	5080008019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			02/28/2014 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.05431	-118.30888	New 79-unit apartment building, 5 stories above grade and 3 basement stories below.  2000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40635	14041-20000-31486	2231 S CARMELINA AVE	90064	11	123B149   977	4259026007	M1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.02996	-118.45539	PLANCHECK FOR T24 ENERGY. REMODEL OF EXISTING 2-STORY OFFICE BUILDING.  TENANT IMPROVEMENT FOR OFFICES, CORRIDORS AND RESTROOMS  ONLY. INTERIOR AND EXTERIOR LIGHTING. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. 22025 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40636	17041-20000-06307	20708 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	06/15/2021 12:00:00 AM	ADDRESS	34.29453	-118.58494	pv1install roof mounted pv system sized 5.7kw (ACM) interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40637	15041-20000-27144	10618 N WHITEGATE AVE	91040	7	207A195   221	2556014056	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.26207	-118.30465	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40638	13041-10000-24473	6900 W BONITA TER	90068	4	150B181   562	5549017006	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			09/06/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.10467	-118.34034	New fire alarm system in a new 3-story apartment building.  Underground parking.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40639	12041-10000-00437	5732 N OAKDALE AVE	91367	3	174B113   157	2153018018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2012 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.17533	-118.56553	PLAN CHECK FOR 7.680KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40640	17041-20000-15903	1026 W 34TH ST	90731	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	34.02414	-118.28985	Recreation center renovation on 2nd floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40641	13041-20000-09893	4737 N KESTER AVE 1-8	91403	4	168A149    18	2264021018	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			04/17/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.15673	-118.45777	Plan check for new 8 unit apartment. NOT a methane hazard site. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40642	16041-10000-14710	10066 N VANALDEN AVE	91324	12	204B121   430	2729004004	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Expired	06/06/2018 12:00:00 AM	ADDRESS	34.2533	-118.54899	PV1, rooftop solar installation 16.4 kW AC system.    (74) CS6P-265P     (1) SE 11400A-US       (1)  SE5000P300 is used.Zero permit fee dues per California Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40643	12041-20000-17404	19755 W VANOWEN ST	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Approved	07/25/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	First time tenant for Unit A18.  No new subpanel and branch circuits added.  Plan check for power and energy.Note: Permit issued under the core/shell application 09041-20000-13618.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40644	19041-10000-41751	11518 W KILLION ST	91601	2	174B169  1012	2350007018	[Q]RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.17117	-118.38283	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 7.6KWac/7.705KWdc. SCOPE OF WORK IS 23 MODULES (LG335N1C-A5) WITH OPTIMZERS (SE P370), LEADING TO A CENTRAL INVERTER (SE7600H-US), NO MAIN PANEL UPGRADE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40645	15041-20000-12657	7600 N LINDLEY AVE	91335	12	186B125   197	2120018009	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.20876	-118.52715	PLANCHECK FOR POWER AND ENERGY. NEW 1-STORY RETAIL MINI-SHOPPING CENTER:  5-Retail tenant spaces. conduit variance has been filed for underground conduits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40646	19041-20001-09561	11806 N MARIPOSA BAY LANE	91326	12	216B113   174	2701035053	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.28538	-118.5661	6/6/2019Changes to an approved set of plans.  changes to the connection point the the serive panel.  this is plan check only.  ((((INSTALLATION OF (4) 5KW TESLA POWERWALL TO A EXISTING SFD WITH A EXISTING PV SYSTEM.  SCOPE OF WORK ALSO INCLUDES 200A SUBPANEL AND 400A MSP UPGRADE.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40647	17041-10001-17158	10250 W SANTA MONICA BLVD # 2980	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1st revision on approved plan for ""Superdry"", changes noted as delta-6. Scope is to reduce the main creaker size from 400A to 300A, update wire size, fault current, and volt. drop accordingly. Load remian the same. This is plan check only, permit is covered under master."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40648	16041-20000-17601	1530 N POINSETTIA PL	90046	4	147B181   533	5548010037	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.09898	-118.34773	Plan check for Title 24 only in existing building, main lobby and GYM area. Total area: 1,477 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40649	14041-20001-15626	4131 N ELLENITA AVE	91356	3	165B117   459	2180005012	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	ADDRESS	34.14508	-118.55917	Fee for expedite only.*****New roof mounted PV system with 300W Optimizers, and 6KW and 3.8KW transformerless inveters.  Total system size is 11KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40650	17041-20002-41458	1333 S BEVERLY GREEN DR 1-4	90035	5	129B165   130	4330004010	[Q]RD2-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			09/12/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.05319	-118.40537	9/12/2018changes to an approved set of plans.  changes to elevator from hydrolic to traction type, reduction in load.  this is plan check only.((((Plan check for power and energy. Project site is a new 2-story, 4-unit apartment building. Work includes a new 600-amp service and a total lighting area of 6,336 sq. ft.Note: Building application has been generated under 17010-30000-00174))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40651	16041-10002-24753	8886 W VENICE BLVD	90034	10	123B169  1455	4312015005	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.02965	-118.38717	PC FOR CHANGES TO APPROVED SET. PROPOSING ADDITIONAL LIGHTING - ADDING NEW CHANDLIERS AND RECEPTACLES TO SCOPE OF WORK. REVISED FLOOR PLANS AND UPDATED TITLE 24. ALL CHANGES ARE MADE UNDER DELTA A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40652	16041-10000-06075	2828 N NEWELL ST	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	PC FOR POWER. SCOPE INCLUDES REPLACING EXISTING MAIN SWITCHGEARS WITH A NEW 1600A 120/205V 3PHASE MAIN SERVICE PANEL. 1600A SERVICE IS FEEDING TWO EXISTING SINGLE  STORY BUILDINGS. SUBPANELS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40653	12041-20000-16720	12445 N GLADSTONE AVE	91342	7	219B161   245	2525018058	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	09/25/2012 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.2961	-118.41248	New 3000 amps service with new equipment for industrial facility.  No new lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40654	14041-10000-24079	3737 S BENTLEY AVE 1-25	90034	5	117B161   984	4252007039	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	Apartment			09/03/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.01482	-118.41685	Plan check for power and energy.  New 5 story multi-family building and a basement parking with 25 apartment units. (Not a methane zone).building permit # 14010-10000-02864	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40655	17041-20001-35080	11807 W LAUREL HILLS ROAD	91604	2	159B169    70	2377004020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	Yes	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.13566	-118.38965	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40656	16041-10000-05751	977 N STONEHILL LANE	90049	11	138B137    79	4493022015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Expired	03/26/2018 12:00:00 AM	ADDRESS	34.07707	-118.48521	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER. DERATING THE MAIN BREAKER TO 175 AMPS. TOTAL SIZE OF THE SYSTEM IS 4.2KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40657	14041-20000-34620	801 S GRAND AVE 1020	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.04581	-118.25842	TI TO OFFICE SPACE. COMBINING 2 UNITS INTO 1. SUITE 1020. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40658	16041-20001-42858	22243 W ROMAR ST	91311	12	204B101   335	2745011057	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	34.25506	-118.61219	1.27.2017 - Plan check for modifications to approved set. Add 60A - AC disconnect only. Update SLD and site plan to reflect this change.=======PC FOR ROOF MOUNTED PV SYSTEM. TOTAL OF 29 MODULES USING AC MODULE SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40659	19041-10001-03946	1375 E LAKE ST	90291	11	114B149   795	4244003034	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.0069	-118.45478	EXPEDITE PER APPLICANT REQUEST>>>>>PLAN CHECK FOR A NEW ROOFTOP SOLAR SYSTEM  AND ENRGY STORAGE SYSTEM IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES 12 MODULES ( Q-PEAK 315W). ONE CENTRAL INVERTER (DELTA SOLIVIA 3.8) AND ONE 13.5KWH  BATTERY(TESLA POWERWALL). SYSTEM SIZE IS 3.8KWac AND 3.78KWdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40660	12041-10000-09998	4023 S LINCOLN BLVD	90292	11	108B149  1856	4229005092	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM			PC Approved	05/02/2012 12:00:00 AM	ADDRESS	33.98965	-118.44736	REMODEL EXISTING YOGURT SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40661	16041-30000-42255	700 W WILSHIRE BLVD	90017	14	129A209    65	5144006020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.04863	-118.25733	Plan check for Title 24 only. Project site is an existing tenant suite within a commercial building. Project scope is a tenant improvement. Total lighting area = 1,915 sq. ft.Note: Building application has been generated under 16016-30000-28764	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40662	14041-20000-21093	10581 1/2 W PICO BLVD	90064	5	126B157   302	4320013036	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM			PC Approved	08/05/2014 12:00:00 AM	PIN	34.04407328	-118.4215389	Change of use from food take-out to bakery (take out only).  Install general lighting.  Plan check for energy.Note: Permit is under 14041-20000-21100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40663	13041-10000-32634	701 WORLD WAY parking	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	33.94352	-118.40045	plan check for energy only. PARKING GARAGE ELEVATOR AND LIGHTING UPGRADE FOR LAX . TOTAL AREA IN SCOPE OF WORK IS TO BE 437,403 SQ FT AREA. 4 TOTAL FLOORS. EMERGENCY LIGHTING IN SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40664	19041-10000-18288	16600 W BOSQUE DR	91436	5	165B137   361	2291008021	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.14704	-118.49553	*Zero permit fee due per AB-1414/SB-1222*(ePlan) New 49 roof mounted PV solar panels with 15.925 kW DC/14.447 kW AC with 225A main panel upgrade and relocation per LADWP. Install (1) 11.4 kW inverter, (49) module with (49) P400 optimizers.*Note; New 225A MSP shall be under separate permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40665	17041-10000-36392	3699 W WILSHIRE BLVD # 110	90010	10	132B193    26	5503028020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.06195	-118.30636	FULL PLAN CHECK FOR SPACE EXPANSION TO EXISITNG 24 HR FITNESS CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40666	16041-20000-15301	902 E 59TH ST	90001	9	105B209    37	6007004004	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	05/10/2022 12:00:00 AM	ADDRESS	33.98705	-118.25942	NEW 1200 AMP SERVICE CORE AND SHELL.  PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40667	14041-10000-11023	1627 W COLORADO BLVD	90041	14	162A225    56	5669016011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.13965	-118.20199	T.I. for existing restaurantArea = 639 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40668	15041-10001-36288	1212 S FLOWER ST 5TH FLR	90015	14	126A207    34	5138026030	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM			PC Approved	12/31/2015 12:00:00 AM	ADDRESS	34.04113	-118.26555	12/31/2015CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 2. CHANGES INCLUDE THE ADDITION AND REDUCTION OF FIXTURES AS WELL AS ADDED LOAD. (((T-24, TI TO THE 5TH FLOOR OF AN (E) COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES  NEW LIGHITNG AND RECEPTACLES, CONNECTED LOAD IS LESS THAN 400AMPS. TOTAL SQ. FT. 11945))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40669	18041-10000-21403	3411 N MANDEVILLE CANYON ROAD	90049	11	150B133    65	4491006006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.10623	-118.50288	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.425 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40670	13041-10002-33040	7700 N FARMDALE AVE	91605	6	189B169   962	2316006012	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.21045	-118.38109	][][]$0 permit fee due to 2012 senate bill 1222.  Changes made to an approved set of plan; # of Jboxes reduced from 3, to 2; roof plan and single line has been revised to reflect the change. Inverter also relocated from original position. ][]]PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE5000A-US. (23) modules TRINA SOLAR TSM-250PA05.18	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40671	10041-20000-20790	11541 N BLUCHER ST bldg2	91344	12	213B145    79	2605002012	QC1-1VL, QP-1VL	North Valley	Granada Hills - Knollwood		YES	1092.00	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	PIN	34.27943684	-118.47043731	Permit expired (BLDG. 2).  EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40672	17041-20000-19950	10532 W BURBANK BLVD	91601	2	174B177   587	2417001046	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			PC Info Complete	06/14/2017 12:00:00 AM	ADDRESS	34.17201	-118.36066	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load less than 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40673	16041-20000-14653	16665-16667 W ARMINTA ST	91406	6	189B137    29	2205009031	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.21497	-118.49677	permit fees $0.00 by state senate bill no.1222PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 136.2KW INTERCONNECTED TO UTILITY GRID.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40674	12041-10000-06033	827 S CATALINA ST	90005	10	132B197   615	5094015006	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			03/16/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	ADDRESS	34.05693	-118.29563	Plan check for new roof mounted 4.6KW photovoltaic system (Transformerless inverter).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40675	19041-10000-45723	657 W REDONDO BEACH BLVD Unit 106	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	02/10/2020 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	33.89279	-118.28709	FULL PC FOR A NEW 400A METER/MAIN SECTION WHICH IS INTERCONNECTED TO AN EXISTING 2000A SWITCHBOARD, NOTE VOLTAGE CLASS IS 480/277 3P,4W. THE NEW 400A METER MAIN, FEEDS TWO TRANSFORMERS, WHICH SUBFEED A NEW 800A SUBPANEL. NOTE PLANS INDICATE A TAP TO AN EXISITING SWITCHBOARD, TAP MAY REQUIRE RELISTING, SUBJECT TO FIELD INSPECTION. TOTAL AFFECTED AREA IS 1806 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40676	18041-20000-22209	6300 N CANOGA AVE Ste 1150	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.18492	-118.59722	Existing highrise commercial office remodel.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40677	10041-10000-20284	1840 N WINONA BLVD	90027	4	150A195   205	5544012045	R3-1	Central	Hollywood	Greater Griffith Park		1904.00	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	11/19/2010 12:00:00 AM	ADDRESS	34.1046	-118.30182	Replacing and existing Fire Alarm System in the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40678	15041-20000-06182	14177 W LA RUE ST	91340	7	210B153   407	2616004023	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.27315	-118.44246	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. POI TO NEW SUBPANEL. 3 STRINGS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40679	10041-20001-00603	5901 W OLYMPIC BLVD	90036	4	132B177   666	5086024025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM			PC Approved	06/09/2010 12:00:00 AM	ADDRESS	34.05771	-118.35996	Revision to approved plan.  Providing disconnecting means for each run of PV source.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40680	13041-20000-19902	5815 W SUNSET BLVD SUITE 204	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.09822	-118.31613	13041-20000-19902existing movie production/photoshoot area. pc for t24 for general lighting. energy only. WORK DONE IN SUITE 204	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40681	12041-20000-15058	7619 N VAN NUYS BLVD	91405	6	186B149   190	2210031003	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			PC Approved	06/28/2012 12:00:00 AM	ADDRESS	34.20886	-118.44896	T.I. to existing space for Physical Therapy.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40682	16041-10000-42291	12901 W CORAL TREE PL	90066	11	102B157    26	4211009005	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.97791	-118.42275	Installing new fire alarm system to commercial site(school & assembly). New Fire alarm panel and 70 fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40683	19041-10000-04588	767 S ALAMEDA ST 1ST FL	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	T24 ONLY PLAN CHECK OF STE 132 IN EXISTING COMMERCIAL BUILDING. TOTAL SQUARE FOOTAGE = 3925 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40684	13041-10000-24106	2920-2930 W ROWENA AVE BUILDING 5	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.10823	-118.26884	NEW BUILDING. APARTMENT.  1 OF 6 TOTAL UNITS. BUILDING 5. NEW 200 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40685	14041-10000-21152	1520 S GLENDON AVE	90024	5	132B153   962	4325027005	R1-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.05413	-118.43924	PV1, INSTALL 8.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(32) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40686	18041-10000-17855	14501 S FIGUEROA ST	90248	15	075B201    96	6119008040	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.90006	-118.28311	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40687	16041-20000-14701	16633 W VENTURA BLVD STE 815	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	TI TO AN EXISTING HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHT NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4335.  SCOPE OF WORK TO BE PERFORMED IN THE 8TH FLOOR SUITE 815.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40688	13041-20001-21117	3256 S BUTLER AVE	90066	11	120B157  1011	4250020010	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.0208	-118.4307	((THIS APPLICATION IS FOR FEE EXPEDITE))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING TOTAL OF 17 MODULES. 3 STRINGS/ INVERTER. NONSTANDARD PLAN. TRANSFORMERLESS INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40689	10041-10000-23965	181 S LA BREA AVE suite# 300	90036	5	138B181  1248	5513019039	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.07124	-118.34424	4 new retail stores. New panels and branch circuits. EPC is for power and energy. (Building G)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40690	11041-10000-02962	6420 W WILSHIRE BLVD	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM			PC Approved	02/15/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	T-24 ONLY TO AN EXISTING 20-STORY COMMERCIAL BUILDING.  WORK IS LIMITED TO 12 FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40691	17041-20000-14857	10651 W LEDEEN DR	91342	7	213B177    20	2529017013	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.27976	-118.36257	pv1install roof mounted pv system sized 12.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40692	19041-10000-53403	3400 S FIGUEROA ST	90007	9	120A203   222	5123022040	USC-1B	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	02/14/2020 12:00:00 AM		Issued	02/14/2020 12:00:00 AM	ADDRESS	34.02167	-118.2799	$0 FEE DUE TO AB1414. NEW ROOF MOUNTED PV INSTALLATION WITH A SYSTEM SIZE OF 619.36 KW DC/ 500KW AC, TAPPED TO EXISTING SWITCHGEAR RATED FOR 1200A, 8 CENTRAL INVERTERS (SUNNY TRIPOWER CORE 62-US), 1568 MODULES (P-19 395),  AND 1000 A BUS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40693	16041-10000-45807	1000 W TEMPLE ST	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/15/2020 12:00:00 AM		Issued	04/15/2020 12:00:00 AM	ADDRESS	34.06171	-118.25046	Plan check for power and energy.  New mixed use building  with 1,449 apartments and 21,744 sq. ft. of commerical space.  Installing 7 new services: (2) at 277/480V (2500 & 3000 Amps) and (5) at 120/208V (5000, 5000, 5000, 5000, & 1200 Amps).  21 typical units.  Project located in methane zone.  Total area = 1,273,986 sq. ft.Bldg. Permit #15010-10000-02603.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40694	16041-20000-22855	4377 N VINELAND AVE	91602	4	165B173   381	2423013022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM			PC Info Complete	06/29/2016 12:00:00 AM	ADDRESS	34.15002	-118.3706	Plan check for a power only. Project site is an existing gas station. Project scope is a service upgrade only. Permit for all subpanels and loads are to be pulled under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40695	17041-10000-04979	16062 W CHASE ST	91343	12	192B141   234	2673019073	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Issued	03/22/2017 12:00:00 AM	ADDRESS	34.22464	-118.48278	PC FOR ENERGY ONLY. PRIVATE STREERT LIGHTING.  TOTAL AREA 181,623 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40696	13041-20000-03167	12100 W OLYMPIC BLVD 2nd floor	90064	11	123B149   575	4259025010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.03215	-118.45396	Plan check for energy only. Red Bull. 2nd floor. relocation of two walls. Relocation of a lighting switch.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40697	16041-20000-09246	21650 W OXNARD ST Ste 1970-1980	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Expired	04/17/2018 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,772 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40698	14041-20000-04589	2858 W LEEWARD AVE	90005	1	133-5A201 263	5077020021	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			02/19/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.0586	-118.28575	Install general/emergency lighting in corridor and stairway.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40699	10041-10001-11782	1200 W 7TH ST	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM			PC Approved	02/17/2011 12:00:00 AM	ADDRESS	34.05136	-118.26616	REVISION OF PERMITTED SET OF PLANS: ON THE SINGLE LINE DIAGRAM, FOR UP-M1 AND UP-M2    THE 400A FEEDERS ARE REMOVED AS MANUFACTURER 'S WIRING INSTALLATION USES INTERNAL WIRING; SWBDS UO-M1 AND UO-M2 ARE REMOVED AND T-M1 AND T-M2  RATINGS ARE REDUCED FRM 300KVA TO 225KVA. THE FC UNITS WERE REMOVED; DP-M1 REDUCED TO 800A; OVERALL, LESS LOADS AND RE-ARRANGED EQUIPMENT IN ROOM L335. ))))))))))Ti in the IT room. New distribution board, panels and circuits. EPC for power and energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40700	13041-10000-20616	5750 W WILSHIRE BLVD 4th floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	34.06227	-118.3542	Title 24 plan check only for lighting revisions in pantry remodel in 4th floor of highrise building.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40701	18041-10001-18760	20505 W ROSCOE BLVD 102	91306	3	192B109   743	2780028075	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.22025	-118.58027	T-24, PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN SPA SPACE. TOTAL SQ. FT. 963.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40702	16041-20002-05968	9723 W BEVERLYWOOD ST	90034	5	126B165   777	4309006001	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.03991	-118.39849	Revisions to approved set.  Modification of rooftop layout of modules.  $0 plan check fee is due to State Senate Bill SB 1222((((Plan check for PV roof mounted system. System size: 13.16kW with 47 modules and  47 microinverter Enphase.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40703	13041-20001-35061	7468 W BEVERLY BLVD	90036	5	138B181   475	5512008034	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.07597	-118.35294	Replace one (8) feet track light with (1) 18Watt LED fixture built in driver.  Unused current limiter call-out was removed for clarification. (((PC FOR T24 ENERGY ONLY. SHOWROOM FOR FURNITURE STORE. RETAIL USE. LOW LOAD.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40704	18041-10001-45019	22216 W MAYALL ST	91311	12	204B101   445	2745011041	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.25385	-118.61117	This is plan check only to revise single line diagram to reflect a new 200A Main panel and PV interconnection to the opposite end of the main breaker. System design remain the same. Panel upgrade to 200A is issued under express permi# 19041-10000-07471. PV permit is still covered under master #18041-10000-45019<<PC FOR NEW ROOFTOP PV SYSTEM FOR (E) SFD. 5KW AC SYSTEM, (16) SOLAR MODULES, (1) 5KW SE5000H-US INVERTER, (16) P320 OPTIMIZERS>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40705	13041-10000-26622	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	FIRE ALARM (EST3 Base Platform) SYSTEM IN WESTFIELD CENTURY CITY MALL PARKING STRUCTURE. 1 facp, 1 bc-1, 1 annunciator and 35 devices.THIS INCLUDES A SPRINKLER MONITOR SYSTEM WITH ANNUNCIATION IN THE (E) MALL FIRE CONTROL ROOM AND AT THE EXISTING MALL 24/7 MANNED SECURITY OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40706	19041-10001-18337	528 W 106TH ST	90044	8	090A201   308	6061024008	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	33.93982	-118.28374	Chnages to approved set, relocation of modules. Original Scope((PC FOR PV-1 , SYSTEM INCLUDES 11 MODULES (HANWHA ) W 320 SOLAREDGE OPTIMIZERS AND 1 3000H INVERTER.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40707	14041-20000-23350	12809 N NEON WAY	91344	12	222B129   215	2601043015	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.30283	-118.51752	PV1.  Install 4.2 kW roof-mounted, utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40708	12041-10000-08053	9720 N AURA AVE	91324	12	201B117   382	2761009021	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.24708	-118.55418	Plan check for 12.48KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40709	14041-20000-21961	717 N DUNN ST	90732	15	021B197   904	7446016006	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	33.74982	-118.30024	single family solar system	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40710	09041-10002-21520	1080 N WESTERN AVE	90029	13	144B193   833	5536023023	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM			PC Info Complete	07/26/2010 12:00:00 AM	ADDRESS	34.09026	-118.30895	THREE-STORY ADDITION ( 4928SQ.FT. ) TO AN EXISTING ONE STORY ,TYPE III-B, STORE BUILDING (M-OCC)  AND CONVERT TO  MEDICAL OFFICE BUILDING (B-OCC).(((((((((((((((((((((((((((   7-26-210 change of service entrance conductor from 3 set of # 300 to two set of # 500 mcm.))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40711	13041-10001-33030	3061 N BROOKDALE ROAD	91604	2	156B169   169	2382006001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.12645	-118.39199	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 9 KW. STANDARD PLAN(36) TRINA SOLAR # TSM-250(1) FRONIUS IG PLUS 7.5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40712	14041-20001-11551	24648 W GILMORE ST	91307	12	177B085    42	2032009032	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM			PC Approved	05/22/2014 12:00:00 AM	ADDRESS	34.18503	-118.66125	due to senate bill 1222 from 2012, $0 fee))))Change to approved set of plan, permit is to cover 30 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40713	14041-10001-03064	7145 S TRASK AVE	90293	11	096B149   653	4116019015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	33.95624	-118.4452	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 6 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(24) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40714	19041-20000-04954	5437 N SATSUMA AVE	91601	2	174B173  1318	2416012028	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Closed	06/04/2019 12:00:00 AM	ADDRESS	34.16971	-118.36764	Plan check for Title 24 only in existing space, change of use from wearhouse to entertainment production. Total area: 4878 sq ft. B#18016-30000-18942	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40715	19041-20000-16302	10860 N SWEETWATER CT pv1	91311	12	210B117   337	2708027***	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.26825	-118.56469	pv1install roof mounted pv system sized  5.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40716	12041-10000-18864	107 S JAPANESE VILLAGE PLAZA MALL BUILDING A	90012	9	129A215   347	5161017022	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Finaled	09/07/2012 12:00:00 AM	ADDRESS	34.04927	-118.2399	CONVERT EXISTING GENERAL RETAIL TO RETAIL BAKERY(1075 S.F.)(TAKE OUT ONLY,NO SEATING , NO EATING ON THE PREMISES )  - NO COOKING ,OR BAKING ON PREMISES.  Load is 100Amps and occupancy load is 14.32 people.  PLAN CHECK ONLY for Energy, No Emergency lighting per applicant.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40717	13041-10000-17591	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			Reviewed by Supervisor	07/26/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	Upgrade of emergency generator in Beverly Center mall from 365kW to 800kW.  New emergency distribution system, including new ATS, feeders, and emergency distribution switchboards.  Power plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40718	13041-20000-33074	15061 W GAULT ST	91405	6	183B145   148	2220004023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.19956	-118.46179	PV1 TRANSFOMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 5KWAC. 23 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40719	18041-10000-39208	7051 W WILLOUGHBY AVE	90038	4	144B181   804	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.08719	-118.34309	Full plan check for a retail and restaurant T.I with (1) panel exceed  600-Amp. Scope include new lighting and equipmnt with a total area of 11,950-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40720	15041-10000-42690	1401 S ALAMEDA ST	90021	14	121-5A215 272	5130021023	M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.02537	-118.23947	FULL PC TO A NEW RESTAURANT, STARBUCKS. SCOPE OF WORK INLCUDES NEW 600AMP SERVICE AND TWO NEW PANELS WITH OUTDOOR LIGHTING. TOTAL SQ. FT. 2197	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40721	11041-20000-18832	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM			PC Approved	09/06/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	energy plan check food court fashion square	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40722	13041-10000-31820	2825 W 8TH ST	90005	10	132B197   413	5077019007	R4-2	Central	Wilshire	MacArthur Park		2122.02, 2122.04	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.05786	-118.28756	PLAN CHECK FOR T24 ENERGY ONLY.  TENANT IMPROVEMENT, 1ST FLOOR ONLY. OFFICES. 1890 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40723	18041-20001-38172	10965 W ELINDA PL	91352	7	201B173   373	2538013011	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM			PC Approved	10/23/2018 12:00:00 AM	ADDRESS	34.24456	-118.36981	Expedite per applicant requestPlan check for PV roof mounted system, system size: 17.49KW DC, 16.086KW AC with 53 PV Modules and 53 Microinverters connected to 225A Panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40724	17041-10001-33330	2064 E MARENGO ST	90033	14	132A225   203	5201013007	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Issued	10/03/2017 12:00:00 AM	ADDRESS	34.05598	-118.20651	PC for T24 only for new lighting in corridor in single story building.COMPLY WITH DEPARTMENT ORDER effective date08/11/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATECEIS 731475	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40725	13041-20000-28015	14400 W ARMINTA ST	91402	6	189B149   664	2212001015	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.21259	-118.44646	POWER PLAN CHECK ONLY FOR EXISTING COMMERCIAL SPACE. EM LIGHTS AND SWITCHING ALREADY CHECKED ON APPLICATION#: 13041-20000-27560	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40726	16041-10000-43558	10250 W SANTA MONICA BLVD UNIT 1780	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER AND ENERGY FOR RETAIL TI. PART OF WESTFIELD CENTURY CITY DEVELOPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40727	16041-10000-32977	1101 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   147	5037025019	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Apartment			09/16/2016 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.01106	-118.29422	Plan check for power and energy  new Appartment mixed use builidng 3 story over parking garage 26 units. Total area:17,345  sq ftNote: Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40728	13041-10000-07780	11680 W GATEWAY BLVD	90064	11	120B153    88	4258001049	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.02874	-118.44295	13041-10000-07780 pc for energy only. less than 400A per applicantCHANGE OF USE FROM RETAIL TO MASSAGE PARLOR WHERE ANY PERSON WHO PROVIDES MASSAGE SERVICES AT THIS PREMISE SHALL BE CERTIFIED AS A MASSAGE THERAPIST OR MASSAGE PRACTITIONER PURSUANT TO CALIFORNIA BUSINESS AND PROFESSIONS SECTION 4600 ET SEQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40729	17041-20000-14074	13050 W SAN VICENTE BLVD UNIT 111	90049	11	129B137   518	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.0483	-118.49125	PLANCHECK FOR T24 ENERGY. BLUE BOTTLE COFFEE . 491 SQFT. UNIT 111	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40730	10041-10000-09279	"3335 S FIGUEROA ST Unit ""N"""	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	07/12/2010 12:00:00 AM		Permit Finaled	08/10/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	"New ""SUBWAY"" Restaurant, Unit ""N"". Existing Service. Plan Check is for Power & Energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40731	15041-20001-01921	20453 W RUSTON ROAD	91364	3	168A111   112	2174021001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.15327	-118.57933	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 15.0KW INTERCONNECTED WITH MSP.(46) SUNPOWER SPR-X21-345 MODULES(3) SUNNYBOY INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40732	15041-10000-16340	10630 N SEPULVEDA BLVD 1ST, 2ND,-ROOF	91345	7	207B145   393	2649011021	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.26357	-118.46694	New fire alarm system replacement, Scope include (1) fire alram panel,  (1) power supply and (74) fire alarm devices. Note; portion permit fee is paid under express permit #: 15041-10000-16301 (((FIRE ALARM SYSTEM ADDITION)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40733	11041-20000-14588	8759 N GLENOAKS BLVD	91352	6	195B177   526	2404026083	(Q)C2-1VL, C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	09/14/2011 12:00:00 AM	ADDRESS	34.22851	-118.36546	Plan check T24 Energy for outdoor lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40734	18041-10002-21263	13003 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM			PC Approved	09/04/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	Change to an approved set by updating the floor plan, all changes under delta-5 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40735	19041-10001-03628	1241 S SOTO ST VOID	90023	14	121-5A221 114	5170017030	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.02743	-118.21975	VOID.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40736	15041-10000-33424	3096 S MCCLINTOCK AVE Building 4	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.02647	-118.28575	New Fire Alarm system to a 5 story commercial building ( Village at USC, building 4 ). (1) FA panels(1) Communication panels(4) Control Panels(1433) FA devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40737	17041-20000-14177	14546 W ARCHWOOD ST	91405	6	180B149   166	2236010027	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Issued	04/28/2017 12:00:00 AM	ADDRESS	34.19275	-118.45042	PLANCHECK FOR T24 ENERGY.  Change of use from Take-out only Restaurant to Restaurant & T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40738	15041-10000-42486	815 N TOYOPA DR	90272	11	126B129   368	4411005012	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.04269	-118.52174	PC FOR POWER ONLY, NEW 800-AMP PULL SECTION WITH 600-AMP DISCONNECT SINGLE FAMILY 2 STORY RESIDENTIAL BUILDING WITH 4 NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40739	12041-20001-12772	1181 N VIRGIL AVE BLDG B	90029	13	145-5A201 239	5542026022	R2-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Apartment			02/26/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.09322	-118.28673	"Changes to approved set of plans. No changes to modules on roof, all changes are on the side of the building involving DWP AC disconnect and distribution panel(s). Please coordinate plan check with that of Building A (12041-20001-12780). Please include 400A service upgrade for ""inspection"" fee period.Enphase photovoltaic system on the roof of apartment buildings.  Building B."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40740	14041-10000-24924	10201 W PICO BLVD 4TH FLOOR	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	PIN	34.05182951	-118.41257696	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. NEWLY CONNECTED LOAD < 400 AMPS. 1595 SQFT.  BUILDING 100. 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40741	16041-10000-09973	1025 E INDIANA AVE	90291	11	111B145   145	4243027006	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.00354	-118.4615	PV1, rooftop solar installation 3 kW AC addition to an (E) PV system  on SFD.      (11) KU2656ZPA    (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40742	10041-10005-09310	1600 N VINE ST	90028	13	148-5A189 346	4307013027	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.1	-118.32647	Existing high rise bldg, two story restaurant. power, lighting and title 24. (( 5 new panels and one 75 kva xfmr    , 65 branch ckts, 2  6k nde , 30k ,75k, 5    100 amps panel and a 200 amps service.  4600 sqft of title 24.(((((((((( CHANGES TO TITLE 24 AND ADDED NEW CKTS TO EXISTING PANELS))))) NEW,  ONE  ONE SET OF PLANS ON JOB SITE AND IDENTICAL SET IN PLAN CHECK MEDI ZANDI))))))))))))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40743	17041-10000-19818	8244 N CANTERBURY AVE	91352	2	192B161   161	2304002003	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Expired	03/31/2024 12:00:00 AM	ADDRESS	34.22116	-118.41717	plan check for 5.8kW battery back-up system with 200A subpanel on single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40744	17041-10000-10731	390 S HAUSER BLVD Lot C	90036	4	135B181   237	5509005014	R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.06807	-118.34975	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 36,000.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40745	19041-10000-30233	6118 W 6TH ST	90048	5	135B177   416	5510026039	R2-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.06486	-118.36209	PLAN CHECK FOR 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER WITH 28 MUDULES USING P400 OPTIMIZERS AND ESS(LG CHEM RESU 10H 9.8KWH0 CONNECTED TO EXISTNG 200A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40746	12041-10000-23093	6357 W MARYLAND DR	90048	5	135B173   472	5510012012	R1-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.06726	-118.3666	Plan check 5.145KW roof mounted photovoltaic system using Enphase M215 Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40747	13041-10000-34104	1935 E 7TH ST	90021	14	124-5A217 213	5164021009	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.03477	-118.2329	PLAN CHECK FOR T24 ENERGY ONLY FOR WAREHOUSE AND OFFICE ( 15635 + 828 SQFT), EMERGENCY LIGHTING.  BUILDING PC# 13014-10000-01022. NEW 2ND FLOOR OFFICE (930 SF) & WAREHOUSE (5447SF) ADDITION  WITHIN  (E) 2-STORY WAREHOUSE .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40748	13041-10000-34885	5263 N BAKMAN AVE	91601	2	171B173   355	2350017019	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Info Complete	03/19/2014 12:00:00 AM	ADDRESS	34.16663	-118.37756	Change of used from theater to buddhist center.  Existing 600A service, existing main panel, and existing subpanels.  Install new roof equipment and lighting.  Plan check for power and energy.Note: The permit is under a separate application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40749	19041-20000-40964	9351 N LAUREL CANYON BLVD	91331	6	198B161   272	2629027014	(Q)MR1-1, (Q)P-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Closed	02/27/2024 12:00:00 AM	ADDRESS	34.23901	-118.41146	PLAN CHECK FOR TITLE-24 ONLY FOR STORAGE ROOM. POWER PLAN CHECKED UNDER PERMIT 17041-20000-09615BLD#: 17016-20000-06967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40750	14041-10000-20891	3150 W WILSHIRE BLVD # 110	90010	10	132B197    39	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.06163	-118.29086	Pc for power and energy 2013 T24. First time tenant, wells fargo bank. total areea 3801 sq ft. B# 14016-10000-15374. (see bldg for cra status)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40751	18041-10000-04211	5161 N LANKERSHIM BLVD	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.16452	-118.37469	PC for T24 only for office TI. Installing new lights and receptacles. Total area 1112sqft. B# 18016-10000-03461.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40752	14041-20001-35562	5421 N PENFIELD AVE	91364	3	171B113    37	2166003008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.16871	-118.56863	PC FOR PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. DOWNSIZING MAIN BREKER. SYSTEM USES POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40753	19041-10000-17778	11150 W SANTA MONICA BLVD #350	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM			PC Info Complete	05/14/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	PC FORTENANT IMPROVEMENT (ENERGY ONLY). SCOPE OF WORK 3,702SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40754	17041-20000-09556	1275 W 30TH ST 1-24	90007	9	120B197   297	5055010019	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			03/24/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.02754	-118.29099	INSTALLATION OF A FIRE ALARM SYSTEM. 1 FACP AND 173 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40755	15041-10000-43480	811 W WILSHIRE BLVD #510	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.04973	-118.2584	PC for energy only, TI to existing offices. High rise building, scope is being done in suite 510. Adding new ligting and power. Total Sqft = 3925	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40756	19041-30000-05843	1155 W 36TH PL	90007	8	120B197   989	5040029017	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.02221	-118.29327	Plan check for a fire alarm system for a 4-story apartment building. Fire alarm system consists of (1) FACP and (33) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40757	16041-20000-32647	6320 N CANOGA AVE 9TH FLR	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.18499	-118.59722	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISITNG PANELS.  TOTAL SQUARE FOOTAGE 1104. SCOPE IS IN THE 9TH FLOOR CORRIDOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40758	19041-10000-16882	5057 N MATILIJA AVE	91423	4	171B153   661	2269004023	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.1629	-118.4336	PC FOR PV1, SYSTEM SIZE IS 8.640KW. SYSTEM INCLUDES 27 LONGI SOLAR MODULES W P320 SOLAREDGE OPTIMIZERS AND 7600 SOLAREDGE INVERTER, adding on to an existing PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40759	17041-10000-17892	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM			Corrections Issued	05/30/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC for replacement of two temporary circuits in hazardous location with two new permanent cirucits from panel A to storage facility and shed. No new load added to system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40760	18041-10000-48357	550 S HOPE ST SUITE 1645	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT INPROVEMENTS IN A CONFERENCE ROOM AND LOBBY OF COMMERCIAL OFFICEPLAN CHECK IS FO RTITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40761	12041-20000-24361	13000 N SAN FERNANDO ROAD	91342	7	222B145   117	2501006023	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.3067	-118.4679	Plan check for energy only. TI WAREHOUSE TO BAKERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40762	17041-20000-38959	1320 E 7TH ST Suite 531	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.03598	-118.24041	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 2,293 sq. ft.Note: Building application has been generated under 17016-10000-26521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40763	19041-20000-06817	9377 S LINCOLN BLVD PV1	90045	11	096B161   838	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Issued	04/24/2019 12:00:00 AM	ADDRESS	33.95496	-118.41468	PV2.  Install 55.85 kW DC / 51.03 kW AC roof mounted grid tied PV system.  (153) modules with 20 and 30 kW rated string inverters.System 4 of 4.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40764	14041-20001-14756	11959 W CREST PL	90210	2	156B165   159	2382020051	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.12324	-118.39873	Fee for expedite only.****New roof mounted PV system with total system size 20.9KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40765	14041-20002-06851	10361 N SOPHIA AVE	91344	12	204B137   108	2679024022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	ADDRESS	34.25908	-118.48758	Modification to approved set.  Upgrade of system size to 7.54 kW via addition of (1) PV module.  $0 plan check submittal fee is due to Senate Bill SB-1222.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40766	13041-10000-18796	2029 S CENTURY PARK EAST SUITE 600	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	13041-10000-18796PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING IN 6TH FLOOR OF OFFICE BUILDING. NO NEW FIXUTRES, REMOVE AND REINSTALL OVER 50% OF LUMINAIRES. USING EXISTING BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40767	19041-20000-32660	6833 N FALLBROOK AVE	91307	12	183B097   743	2026008043	(Q)RD2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.19448	-118.62378	New fire alarm system in (E) 2-story apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40768	18041-10000-47064	7920 W SUNSET BLVD	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.09787	-118.36238	Full plan check for theatre T.I. Scope includes new lighting and equipment with the load more than 400-Amp of 2773-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40769	15041-10000-32756	1133 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.03014	-118.2206	T-24, remove HID light fixtures and replace with new LED fixtures in a warehouse. Total area 14,288 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40770	15041-10000-40842	15803 W STAGG ST	91406	6	198B161   319	2629027017	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.21218	-118.47749	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE EXISTING HID LIGHITNG FIXTYRES AND REPLACE WITH NEW LEDS.  TOTAL SQUARE FOOTAGE 10944	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40771	11041-10000-25059	1625 N SCHRADER BLVD 3rd Floor	90028	13	148-5A187 241	5547015029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	08/08/2012 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.10046	-118.33259	T.I. to an existing Medical Office includes new exam rooms and reconfiguring blood drawing nurse stations or 3rd Floor. Plan check for power and  energy. New panel and branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40772	18041-20000-12491	10265 W WOODBRIDGE ST	91602	4	165B177   517	2424022011	RE11-1-H-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.14859	-118.35475	permit fee $0.00 by state senate bill no. 1222pv1install roof mountred pv system sized 22kw interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40773	16041-10001-23845	2189-2195 E WHITTIER BLVD	90023	14	124-5A221 121	5183021023	R3-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Approved	08/20/2018 12:00:00 AM	ADDRESS	34.03614	-118.21937	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES ARE CLOUDED UNDER DELTA 2 REFLECTING CHANGES ONLY TO THE RELOCATION OF MSA TO OUTSIDE OF BUILDING AND UPSIZING BREAKER SIZE TO PANEL A TO 400A INCLUDING FEEDERS. NO NEW LOADS OR CHANGES TO LAYOUTS HAVE BEEN DONE  ORIGINAL PERMIT Full plan check. Repair of fire demage to a commerical building single story core and shell, 3 different tenant spaces. New service rated at 800 amps 120/240 3phase 4 wire. Installing lighting and power. Total sqft = 7597.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40774	14041-20000-21270	15760 W VENTURA BLVD #1929	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.1552	-118.47684	PC FOR T24 ENERGY ONLY. REMODELED OFFICE, NO PATIENT CARE AREA. TOTAL AREA 275 SQ FT. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40775	12041-10000-23586	17127 W GERMAIN ST	91344	12	207B133   717	2695007013	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.26251	-118.50643	FOR A SFD, ROOF-MOUNTED 3.43 KW PHOTOVOLTAIC SYSTE USING MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40776	15041-10004-08090	410 W 8TH ST	90014	14	127-5A209  75	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.04466	-118.25638	"Changes to an approved set of plans. All changes are clouded under delta 15. Changes include adding a circuit for a new inverter to panel ""L1"", removing bug-eyes and replacing emergency lighting with inverter, and updated emergency photometrics."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40777	16041-10000-13770	9830 N SAN FERNANDO ROAD G1-1	91331	7	201B165    77	2537015042	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.24931	-118.40346	PC for energy only. Remove HID fixtures and replace with new LED fixutres. Total sq ft : 10656.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40778	19041-10000-15945	3303 N NORTH BROADWAY FLR 3,4	90031	1	138A225    15	5208012021	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/04/2021 12:00:00 AM	ADDRESS	34.07394	-118.20626	NEW FIRE ALARM SYSTEM IN THE BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40779	18041-20000-18018	20741 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.2951	-118.58597	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40780	13041-20001-27362	47 E WAVE CREST AVE 1-2	90291	11	108A143   215	4226003028	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	33.99046	-118.47481	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING 28 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 4 STRINGS WITH COMBINER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40781	19041-20000-36014	6080 W CENTER DR Ste 550	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40782	17041-20003-14437	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	"10/23/2017changes to an approved set of plans.  changes noted delta 7.  changes include relocating existing equipment from distribution board ""DBA"" to house section ""MMH"".  no change in connected load.  this is plan check only.  10.18.2017 - Plan check for modifications to approved set. Update SLD to show actual connected load for conveyor system and panel MCP (400A). Update inverter to 10kW single phase 277V. Relocate equipment - panels 1LA, HA, HL, transformer T-LA, and inverter. Changes clouded delta 6.=======08/04/2017 Changes to an approved set of plans. All changes have been clouded and marked as Deltas 1, 2, and 5. Loads have been recircuited/relocated and there have been slight lighting changes.*****Previous Work Description*****Plan check for Power and energy wearhouse and office space T.I. new panels, lighting and receptacle. Total newly connected load exceed 400A feed from Existing 800A switch gear. Total area indoor lighting: 249,391 sq ft. B#17041-30000-04976"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40783	15041-10000-03526	1301 W STORM PKWY	90501	15	045B197    71	7347018033	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	33.81706	-118.29917	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40784	18041-20000-11876	129 W COLLEGE ST	90012	1	135A215   136	5409007003	UC(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			Reviewed by Supervisor	04/11/2018 12:00:00 AM	ADDRESS	34.0632	-118.23483	plan check for temporary power 1600 amp service, construction site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40785	13041-20000-12256	11601 W WILSHIRE BLVD #1680	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	EXISTING OFFICES. RELOCATION OF LIGHTING FIXTURES AND CHANGING WALL PARTITIONS. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED FROM THIS APPLICATION. TOTAL AREA COVERS SCOPE OF WORK, OPEN OFFICE AND PRIVATE OFFICES. 2289 SQ FT. WORK ODONE IN SUITE 1680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40786	18041-10000-29598	10250 W SANTA MONICA BLVD #9160	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM			PC Info Complete	08/28/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PC TO A FIRST TIME TENANT (E) retail kiosk within Westfiled Century City Mall; SCOPE OF WORK INCLUDES NEW PANEL, LIGHTING, AND RECEPTACLE LOAD. TOTAL SQ. FT. 280.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40787	17041-20000-35352	11331 W OSBORNE ST	91342	7	213B173   378	2530020036	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/29/2020 12:00:00 AM		Permit Finaled	02/18/2022 12:00:00 AM	ADDRESS	34.27726	-118.37816	800A 208Y/120V 3ph-4w service, distribution, power, and lighting for new commercial building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40788	12041-20002-30584	735 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Issued	08/06/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	Addition of two 600A panels/sections.  Conduits only, no loads nor wires.TENANT IMPROVEMENT. NEW 1600 AMP SERVICE, ADDITION OF 1600 A SWITCHBOARD,  AND BUS DUCT. THERE IS NO LOAD CONNECTED TO THE BOARD. FUTURE TENANT WILL PULL THE PERMIT FOR THEIR WORK. ONLY CONDUIT FOR ONE FUTURE TENANT WILL PROVIDED. (ONE 45 X-FORMER WITH ALL DISCONNECT AND FEEDERS MOVE TO A NEW LOCATION WHICH WILL MAINTAIN ALL THE X-FORMER DISCONNECT AND TAP LENGHT REQUIMENT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40789	19041-20000-33459	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.17126	-118.58861	INSTALL (1960) NEW FIRE ALARM DEVICES WITH (3) ALARM PANEL AND (3) COMMUNICATION PANELS FOR COMMERCIAL BUILDING KAISER PERMANENTE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40790	14041-10000-32342	1950 E 110TH ST	90059	15	088-5A215 495	6067005008	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	33.93504	-118.23784	PV1.  Install 4.58 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40791	13041-10000-29268	5456 S MCCONNELL AVE	90066	11	102B161    26	4211009031	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	33.97743	-118.41904	CONVERSION OF EXISTING OFFICE BUILDING TO NEW CHARTER SCHOOL. EXISTING 1200A SERVICE. FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK IS > 400A. ADDING TOTAL 7 NEW PANELS WITH NEW CONNECTED LOAD OF 896A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40792	15041-10000-42066	4619 N CARITINA DR	91356	3	168B117   516	2178020013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Expired	02/12/2018 12:00:00 AM	ADDRESS	34.15408	-118.5566	PV1 SFD TOTAL SYSTEM SIZE 14KW AC USING 2 CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40793	15041-20000-33440	15120 W MULHOLLAND DR	90077	5	159B145   559	4378004016	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.13052	-118.46188	PV1, roof mounted solar panel, 14.72 kW AC system. (45) modules: SunPower SPR-E20-327, (1) Inverter SMA SB 7700TL-US-22, (1) Inverter SB 7000TL-US-22.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40794	14041-20001-13472	16726 W OAK VIEW DR	91436	5	168B137   383	2289021004	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.15726	-118.49872	Expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40795	17041-20001-03636	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022058	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	34.21384	-118.44905	2/27/2018changes to an approved set of plans. changes noted delta D E F.  changes include revision of equipment/floor lay-out and circuits.  no additional load.  this is plan check only.    ((((New 6-story commerical building gymnasium and parking (3 levels fitness center with 3 levels parking).  Underground 3000A 208V 3ph-4w service.  176,784 sq ft.  Plan check for power and energy.  Electrical permit has been issued under 15041-10000-28641 under previous design (same engineer).  Full resubmittal due to extensive scope of work changes - from 2000A to 3000A service, complete system redesign.))))Building permit under 13010-10000-04552.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40796	11041-20000-00511	20335 W SORRENTO LANE Bld. 7	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Apartment			01/11/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.27829	-118.57701	New fire alarm system for Building 7.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40797	16041-10000-04105	2725 N PREWETT ST	90031	1	139-5A223  30	5206025012	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Expired	03/06/2018 12:00:00 AM	ADDRESS	34.0783	-118.20856	PV1, rooftop solar isntallation 3kW system(6) KU2656ZPA(1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40798	19041-10000-26853	426 S PALOS VERDES ST	90731	15	018B201   825	7455027932	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	12/07/2020 12:00:00 AM	ADDRESS	33.74102	-118.28119	Plan check for a PV2 carport mounted system with 330KW AC / 375.8kW DC. Scope includes (1) 800 Amps service panel, (11) 30kw inverters, and 864 modules interconnecting through the main service panel.PERMIT FEE IS $ 0 IN ACCORDANCE WITH AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40799	13041-10000-24536	6801 W HOLLYWOOD BLVD STE 101	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.10229	-118.33907	Replacement of existing lighting system with new lighting for retail space TI.  Title 24 plan check per inspector's request (under express permit 13041-10000-22614).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40800	18041-10000-26789	5901 W CENTURY BLVD 2ND,3RD,6T-H	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	33.94572	-118.38685	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR OFFICESS ON THE 2ND, 3RD AND 6TH FLOOR. 42,053 SQFT.  PERMIT FOR RECEPTACLES PULLED UNDER 18041-40000-21756BUILDING PERMIT NUMBER 18016-10000-15902.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40801	18041-10000-11526	12465 W OXNARD ST	91606	2	177B165   713	2333010072	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Issued	03/30/2018 12:00:00 AM	ADDRESS	34.17956	-118.40504	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40802	17041-10000-09019	1748 W CUMBRE DR	90732	15	012B189    24	7560028001	R1-1XL	Harbor	San Pedro	Coastal San Pedro, Northwest San Pedro	YES	2974.00	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	33.72945	-118.31623	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 89 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40803	19041-10000-30784	19000 W SATICOY ST	91335	3	186B121   163	2104016017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.20823	-118.54728	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40804	18041-10000-35876	932 W 85TH ST	90044	8	097-5A199 181	6032013901	P-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.96112	-118.29025	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40805	14041-20000-35188	1312 E 55TH ST	90011	9	108B209   774	5104019012	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	33.9929	-118.25158	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:4.5KW. MICROINVERTER NON STANDARD PLAN.(18) HYUNDAI HIS M250(18) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40806	09041-20001-20867	9261 N JORDAN AVE	91311	12	198B105   217	2746013035	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			04/21/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	06/14/2010 12:00:00 AM	ADDRESS	34.23886	-118.60411	Plan check revision to power and energy for field changes to approved plans. Tenant improvement - remodel of office/warehouse. Over 400A load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40807	19041-20000-21341	20700 W SESNON BLVD #172-pv1	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	pv1install roof mounted pv system sized 5.025KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40808	18041-10000-17410	12302 W MONTAGUE ST	91331	7	204B165   220	2537014***	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.25514	-118.40071	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40809	13041-10000-02934	500 W WORLD WAY NORT J5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	First time tenant (restaurant) in existing tenant space. Electrical submittal for power and energy. Total connected load: 422.8A. 2762 sqrft. Space 5J Terminal 5.Note: A variance to separate fire alarm plan shall be submitted before issue the permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40810	16041-10000-14715	11359 W MCCUNE AVE	90066	11	114B157   161	4234003056	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.01184	-118.42231	PV1, rooftop solar installation 5kW AC  (22) TRIEX U290        (1) SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40811	13041-10000-19342	1611 N NAUD ST	90012	1	136-5A217  49	5409002031	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.06819	-118.22779	TENANT IMPROVEMENTS TO AN EXISTING BUS MAINTENANCE FACILITY.  CHANGE OF USE FOR PORTIONS OF BUILDING FROM MAINTENANCE TO OFFICE AND CONSTRUCT (N) WALL OPENINGS FOR BUSES. no work being done in hazardous location per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40812	13041-20000-34659	21600 W OXNARD ST 9th floor	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	34.179	-118.6002	Existing High-rise office building.  Change to lighting, new UPS,  123 new branch circuits.  Load is less 200 amps per engineer, subject to field verification.  PLAN CHECK ONLY for Energy, with Emergency lighting.  PERMIT FEES ARE UNDER INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40813	11041-20001-17415	609 W 7TH ST	90017	9	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.04764	-118.25687	add 160kva ups and upgrade 150kva to 160 kva	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40814	16041-20000-17300	8139 N CORBIN AVE	91306	3	189B117    78	2106014001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.21779	-118.56245	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.SYSTEM IS TO BE ADDED TO AN EXISTING PV SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40815	18041-10000-33746	1722 1/2 S NEW ENGLAND ST	90006	1	126B197   380	5056014017	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.04249	-118.28758	smoke detector	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40816	15041-10000-30289	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.01318	-118.34004	New 4-stories Kaiser Permanente Medical Office BuildingNOTE THAT ITEM QUANTITIES SUBMITTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40817	18041-10000-10511	1218 N OLANCHA DR	90065	1	154-5A221 375	5475008004	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.11593	-118.21781	Install New rooftop solar system for an (E) single family dwelling. System size 7.1kW AC/ 8.8kW DC with (31) modules and enphase/microinverter, and enphase combiner box	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40818	18041-10000-13127	15275 W SUNSET BLVD 5-112B	90272	11	129B125   834	4423016008	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.04694	-118.52505	PLAN CHECK FOR POWER AND ENERGY FOR TI FOR FIRST TIME TENANT TO EXISTING CORE AND SHELL RETAIL SPACE. TOTAL AFFECTED AREA 362 SQ. FT. B#18016-10000-10868	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40819	14041-10000-24504	6912 N RANCHITO AVE	91405	2	183B153   822	2216019020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Expired	11/02/2016 12:00:00 AM	ADDRESS	34.1963	-118.43552	PV1, INSTALL 6.885 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(27 ) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40820	17041-20000-00797	5243 E LATHROP ST	90032	14	147A237   184	5309010029	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.09707	-118.16577	Plan check for a PV1 roof-mounted PV system. System size is 2.3 kWac and consists of (7) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40821	12041-20001-25511	10840 W WILSHIRE BLVD	90024	5	132B153   401	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.05924	-118.44131	Changes from previously approved plans.  Changes include new liighting circuits and rearrangement of loads.  All changes changes indicated by DELTA 14-17.*****B OCCUPANCY, EMERGENCY EXIT AND LIGHTING REQUIRED. PROPOSED ADDITION AND REMODEL TO PORTION OF EXISTING BLDG- CONVERTING A PORTION OF EXISTING THEATER TO A RESTAURANT AND BAR.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40822	14041-10000-03555	16847 W VENTURA BLVD	91436	5	168B133    86	2259010001	C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/07/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.15927	-118.50037	T24 PART 6 ENERGY FOR (E) SMART & FINAL. SCOPE OF WORK < 400A. PLAN CHECK FOR ENERGY ONLY, FOR AN APPROX. 1106 SQ FT AREA. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.NOTE: PERMIT FEE ALREADY CALCULATED UNDER INSPECTION FEE PERIOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40823	13041-20001-09118	1950 E WASHINGTON BLVD	90058	14	118-5A215  29	5167005015	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			PC Approved	09/28/2013 12:00:00 AM	PIN	34.01879134	-118.23748008	Modification to previously approved set of plans.  Change to classification and misc other changes.     <<<clean energy propane station>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40824	16041-20000-02552	20701 W PLUMMER ST	91311	12	201B109   305	2748003071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.24287	-118.58449	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 37,000 sq. ft.Note: Building permit has been pulled under 15016-10000-03392	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40825	14041-20001-21509	3331 N BARHAM BLVD	90068	4	159B181   387	5579015006	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.13163	-118.34483	PV2.  Install 39.0 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40826	18041-20000-45694	1201 N EL CENTRO AVE	90038	13	144B189   323	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Apartment			11/30/2018 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	09/08/2021 12:00:00 AM	ADDRESS	34.09274	-118.32458	PV2.  Install PV roof mounted system, system size 76.3kW with 218 PV Modules and 6 string inverters (11.4kW each).PV Modules are mounted on 3 separate buildings.   Supply side connection.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40827	19041-10000-11975	10751 W ROSE AVE	90034	5	120B161   296	4254012058	R1-1, R3-1, R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.02644	-118.41435	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40828	15041-20001-01527	7012 N LONGRIDGE AVE	91605	2	183B157   469	2327006065	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.1978	-118.4213	Expedited per customer request.PV1. Install roof mounted PV system sized (30) Sunpower SPR-327NE Modules(1) Sunpower IG Plus Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40829	16041-20000-13896	699 W EXPOSITION BLVD 110	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.01842	-118.28508	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to Office 110. Total lighting area = 94 sq. ft.Note: Building application has been created under 16016-10000-08386	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40830	13041-10000-27146	10226 N BETTY LOU LANE	91042	7	204A197   153	2558034003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.25491	-118.30019	PV1.  Install 6.75 kW DC roof-mounted solar array, interconnect with main service panel.  1 transformerless inverter: SolarEdge SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40831	16041-10000-11126	2113 N STONEY HILL ROAD	90049	11	150B137    65	4493031***	(Q)RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Expired	06/14/2018 12:00:00 AM	ADDRESS	34.10423	-118.49028	Ground mounted solar installation on SFD, 10kW AC.      (35) CS6X-315P         (1) FRONIUS PRIMO 10.0-1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40832	13041-20000-08610	17311 W PARTHENIA ST Pv-1	91325	12	195B133   406	2768016003	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.22872	-118.51146	New rooftop mounted PV.   2.5kW inverter and one 5kw inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40833	14041-20000-18536	10601 N VALJEAN AVE	91344	12	207B137   589	2679020011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.26279	-118.48707	PV1Install roof mounted solar array on SFD. System size: 3.8kW(1) SolarEdge 3800A-US transformerless inverter(18) SolarEdge P300 power optimizers(18) REC Solar REC255PE(BLK) pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40834	15041-10000-32873	22141 W LONDELIUS ST	91304	12	195B101   248	2010007032	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.22943	-118.60978	PV1, INSTALL NEW 14.04 KW DC ROOF-MOUNTED SOLAR ARRAY FOR  RESIDENTIAL BULDING. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222 (52) MODULES: LG 270 W (2) INVERTER: SMA SUNNY BOY SB-7000TL-US AND SMA SUNNY BOY SB-6000TL-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40835	14041-10001-01731	508 W 155TH ST	90248	15	072B201   186	6120026011	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM			PC Approved	08/20/2014 12:00:00 AM	ADDRESS	33.89043	-118.28345	Expedited RSES plan check per applicant request.{{PV1, Install 1.47 KW DC roof-mounted mico inverter solar array on a house, interconnect with main service panel. (6) Modules: Canadian Solar CS6P-245P with (6) Inverters: Enphase M215.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40836	19041-10000-23543	1327 S HILL ST	90015	14	124-5A207  37	5134025010	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM			PC Info Complete	06/19/2019 12:00:00 AM	ADDRESS	34.03703	-118.26296	PC for T24 only scope of work includes new lighting and controls in a car detail garage. Note that there is no spray booth or auto repair in this area. Total affected area is 3354 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40837	14041-20000-06974	17319 W BIRCHER ST	91344	12	213B133   237	2607006023	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.28226	-118.51161	Roof mounted PV system with 8KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40838	14041-20000-33490	1603 W 85TH ST	90047	8	097-5A195 207	6034026015	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	33.96103	-118.30486	PV1 SFD. TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER SYSTEM. USES ENPHASE M250. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40839	12041-20000-04150	8600 S CENTRAL AVE	90002	9	097-5A209 255	6043001027	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM			PC Info Complete	02/23/2012 12:00:00 AM	ADDRESS	33.95988	-118.25616	T.I. to existing space (Subway).  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-09146	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40840	18041-10000-09440	4050 S LINCOLN BLVD	90292	11	108B149  1389	4230002008	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	33.98922	-118.44633	PC FOR T-24 COMPLIANCE PER APPLICANT REQUEST FOR LIGHTS IN RESTROOM. B# 17016-10000-27920 FOR RELOCATE RESTROOM DOOR & INSTALL NEW WALK-UP WINDOW AND NEW ENTRY DOOR AT EXISTING RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40841	18041-10000-21018	1844 W CYPRESS AVE	90065	1	148-5A215 107	5442004011	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.10065	-118.23482	PV2, ROOF MOUNTED SOLAR SYSTEM TO A COMMERCIAL BUILDING. (91) MODULES AND (2)CENTRAL INVERTERS, 12KW AC EACH. TOTAL SYSTEM SIZE IS 24KW AC AND 27.7KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40842	19041-20000-40784	3696 N ALTA MESA DR	91604	2	162B161   713	2384015011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.13694	-118.40998	PV roof mounted system, PV system size: 11.88KW DC, 10KW AC with 36 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40843	16041-20000-05994	4328 N TOSCA ROAD	91364	3	166-5A109 248	2172020066	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.14846	-118.59076	Plan check for PV roof mounted system. System size 6.0kW with 20 modules  and 2 inverters (3.0kW).  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40844	19041-10000-29715	830 W 70TH ST	90044	8	102B197   827	6013004900	OS-1XL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	33.97626	-118.28837	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40845	15041-20000-26638	221 N FIGUEROA ST 8th Floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for Title 24 only. Project site is the 8th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 17,767 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40846	18041-20001-07220	2208 N STRADELLA ROAD	90077	5	153B145   195	4377030002	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.11283	-118.46263	Revision to approved set of plans.  Miscellaneous SLD changes.  (((PV1.  INSTALL ROOF MOUNTED PV SYSTEM AND 13.5 KWH ENERGY STORAGE SYSTEM - PV SYSTEM SIZE 6.6KVA CONSISTING OF 1 CENTRAL INVERTER(SOLIVA 6.6) WITH 27 MODULES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40847	18041-20000-07779	20657 W CHESTNUT CIR (#261)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Issued	03/02/2018 12:00:00 AM	ADDRESS	34.2938	-118.58454	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40848	19041-20000-53276	8631 W 3RD ST SUITE#531	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.07373	-118.38036	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. TOTAL SQ. FT. 1407.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40849	18041-10000-45659	400 N VERMONT AVE	90004	13	138B197  1337	4332019093	PF-1XL	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Issued	11/30/2018 12:00:00 AM	ADDRESS	34.07798	-118.29148	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40850	18041-10001-00348	2509 W 76TH ST	90043	8	099B189    51	4009015014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	33.97107	-118.32127	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40851	18041-20000-00327	7453 N VANALDEN AVE	91335	3	186B121   462	2104020015	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.2063	-118.54929	19.67$ permit fees due to senate bill 1222ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.9KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40852	14041-10000-28291	19839 W RINALDI ST	91326	12	210B113   190	2701040011	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.27548	-118.56736	Title 24 plan check only.  Total area = 1,255 sq. ft.T.I. to existing retail space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40853	19041-10000-21682	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	33.98489	-118.42552	POWER PLAN CHECK FOR EQUIPMENT AND CONNECTED LOADS IN AN AT&T DATA AND COMUNICATION CENTER. EQUIPMENT ARE FED FROM TWO EXISTING 1200A 480 3-PAHSE SWITCH BOARD. THE BUILDING IS DEDICATED FOR AT&T AND SERVED BY FOUR 5000A SEVICES. SCOPE INCLUDES TWO NEW 250KVA TRANSFORMERS, TWO 250KVA POWER SUPLIES WITH 4 EXTERNAL 123AH BATERRIES. TOTAL CONNECTED LOAD IS MORE THAN 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40854	13041-10001-35680	1133 S LONGWOOD AVE	90019	10	132B185   865	5084023036	R2-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	05/23/2014 12:00:00 AM	ADDRESS	34.05474	-118.33956	Expedited RSES plan check per applicant request. {{PV1, Install 4.75 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 5000A-US. (19) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40855	16041-20000-03857	5511 N CAHUENGA BLVD	91601	2	174B177   872	2416020038	CR-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Closed	12/08/2016 12:00:00 AM	ADDRESS	34.17036	-118.36172	Plan check for Title 24 only for exisitng space. Total area: 2,900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40856	17041-20000-16535	11133 N BALBOA BLVD	91344	12	210B133   328	2697025004	(T)(Q)C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.27305	-118.50254	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 145,599 sq. ft.Note: Building application has been generated under 17016-20000-12921	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40857	16041-20000-12665	527 E 35TH ST	90011	9	117A207   149	5120022021	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.01511	-118.26687	PV1. ROOFMOUNTED SOLAR SYSTEM.  MICROINVERTER STANDARD PLAN. SYSTEM SIZE: 2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40858	19041-20000-01682	732 S LOS ANGELES ST C	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.04251	-118.25112	PLAN CHECK FOR TITLE 24 ONLY FOR HAIR SALON. SCOPE INCLUDES TOTAL SQFT OF 1151.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40859	17041-10000-43511	2980 W LOS FELIZ BLVD	90039	13	157-5A207 140	5435009021	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.12549	-118.26436	NEW LIGHTING FIXTURES IN DINING AREA OF EXISTING RESTAURANTPLAN CHECKIS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40860	18041-10000-03633	1724 N HIGHLAND AVE 1st &2nd-Floor	90028	13	148-5A185  63	5547011035	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.10238	-118.3385	Plan check for Title 24 only in existing space T.I. in appartment building. Total area:  2910 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40861	19041-20000-37798	10810 W HORTENSE ST MS5	91602	2	168B177   842	2421030001	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.15462	-118.36623	New 600A 240/120V 1ph-3w service supplying (5) SFDs and house panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40862	17041-10000-08354	6300 W WILSHIRE BLVD SUITE#1890	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40863	17041-10000-39533	5809 W 76TH ST	90045	11	102B169   454	4104014007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	33.9718	-118.38337	Installation of new roof-mounted solar PV system,  total 2.5 kw AC  in a 1 or 2 family dwelling. (11) modules with (11) enphase microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40864	19041-10000-36151	740 S ALVARADO ST	90057	1	132A203   201	5141019007	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Apartment			09/11/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	09/01/2021 12:00:00 AM	ADDRESS	34.05522	-118.27735	Fire Alarm Plan check for 6 (N) story apartment building. (1) FACP and (240) Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40865	16041-20001-04594	13932 W OTSEGO ST	91423	4	171B153   681	2269011006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	34.16259	-118.43686	Changes to approved plans.  Change of design to central inverter standard plan using (1) Fronius IG-4000 with (18) Samsung (LPC241SM modules.  (((Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (18) modules, (18) micro-inverters, and (1) load center. Standard plan is being used.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40866	15041-10000-21032	2239 S PONTIUS AVE	90064	5	126B153  1005	4322024039	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.03869	-118.43767	PV2, INSTALL 3900 KWDC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE WITH THE MAIN SERVICE PANEL. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222.(150) MODULES: KYOCERA KD260GX-LFB2 260W(4) INVERTERS : SOLAREDGE SSE9K-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40867	18041-10000-20615	8510 N BALBOA BLVD	91325	12	192B133    87	2689019011	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.2251	-118.50158	PLANCHECK FOR POWER AND ENERGY. ADDITION OF EV CHARGERS AND OUTDOOR LIGHTING.  81,827 SQFT.BUILDING PERMIT # 18020-10000-00234	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40868	16041-20000-24579	803 E 25TH ST	90011	9	120A209   318	5131022025	R3-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Refund in Progress	11/10/2016 12:00:00 AM	ADDRESS	34.02162	-118.25858	Plan check for a Pv1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (10) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40869	15041-10000-24875	5453 W HOLLYWOOD BLVD B	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.10193	-118.30871	TI FOR RESTAURANT (1430 SQ FT) plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40870	17041-30001-34584	5510 S LINCOLN BLVD #105	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	33.97299	-118.43051	Plan check for Title 24 only in existing space. replace new lighting fixtures in office and receptation. Total area: 3105 sq ft.Permit refered to application number#17041-90000-34584	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40871	16041-10000-44688	3674 N BARHAM BLVD (BUILDING-L)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.13944	-118.34135	WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW MICROWAVE CIRCUIT FOR 45 UNITS AND UPGRADING NEW UNIT PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40872	19041-10000-23870	10925 W HARTSOOK ST	91601	2	171B173   764	2419001046	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1255.01	Electrical	Electrical	Apartment			06/21/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.16365	-118.36887	Plan check for fire alarm system with (1) fire alarm panel, (2)power supplies,and (176) fire alarm devives.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40873	18041-10000-00508	10356 N GERALD AVE	91344	12	204B137   118	2684017010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			Reviewed by Supervisor	01/17/2018 12:00:00 AM	ADDRESS	34.25917	-118.49456	PC for rooftop solar for 15.2kW AC system for SFD. Installing 59 modules, with two central inverters and 125A subpanel. DC size is 16.815 kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40874	14041-10000-21021	333 S HOPE ST E LEVEL	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.05326	-118.25292	"PC FOR ENERGY ONLY UNDER 2008 CODE. REMODEL AT ""E"" LEVEL ONLY - MEN'S & WOMEN'S RESTROOMS TO PROVIDE ACCESSIBILITY COMPLIANCE.  424 SQ.FT.B# 14016-10000-10074."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40875	18041-20000-46219	5427 N COSTELLO AVE	91401	4	174B153  1227	2247010019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.16941	-118.4379	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV1 system. Addition system size is 5.51 kWdc/5 kWac and consists of (1) inverter and (19) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40876	13041-10000-17588	1141 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.03008	-118.22062	13041-10000-17588Change of use from warehouse to office and interior tenant improvement. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40877	19041-10000-50400	8848 N SOPHIA AVE	91343	12	195B137   443	2688018034	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.23167	-118.48825	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 16 (SOLARIA 355W) MODULES, 16 (SOLAREDGE P370) OPTIMIZERS, 1 (SE5000H-US) CENTRAL INVERTER, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 5.68KW DC & 5.00KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40878	16041-10000-21650	1800 E MARTIN LUTHER KING, JR BLVD	90058	9	115-5A215  23	5117019016	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	01/13/2023 12:00:00 AM	ADDRESS	34.00965	-118.24068	PLAN CHECK FOR POWER AND ENERGY. NEW INDUSTRIAL BUILDING (116,724 S.F.) AND MEZZANINE FOR 2 TENANTS. SCOPE INCLUDES A NEW 2000A, 277/480V, 3PH, 4WIRE SERVICE, NEW DISTRIBUTION BOARDS, NEW TRANSFORMERS, AND NEW SUBPANELS FOR OFFICE/WAREHOUSE SPACES. TOTAL AFFECTED AREA IS 143430 SQ. FT. SHELL ONLY.  B# 13010-10001-04517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40879	13041-10000-24637	236 S LOS ANGELES ST TEMP	90012	14	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Closed	03/18/2015 12:00:00 AM	ADDRESS	34.04922	-118.24386	TEMPORARY POWER PLAN CHECK FOR NEW 800A UNDERGROUND SERVICE FEEDING 3 PANELS, (1) 112 KVA XFORMER AND EQUIPMENT FOR CONSTRUCTION OF FUTURE 5-STORY BUILDING,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40880	18041-10000-17403	2240 S COLBY AVE	90064	11	123B153   251	4260016003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.03498	-118.44398	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40881	17041-20000-37699	13337 W ALMETZ ST	91342	7	231B157   156	2582017032	RS-1	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.3276	-118.42322	PV1.  Install 7.13 kW AC roof mounted grid tied PV system.  (24) modules with Enphase IQ6-60 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40882	18041-20000-08987	1000 S GRAND AVE	90015	14	127-5A209 199	5139009015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Closed	05/20/2019 12:00:00 AM	ADDRESS	34.04258	-118.26079	ti to an existing commercial space.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40883	19041-10000-31918	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	34.18421	-118.60617	PC for a new fire alarm system for a corn and shell  grocery store. Scope of work is a new fire alarm panel with 10 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40884	17041-20000-31276	1731 S BARRY AVE 1-35	90025	11	126B149  1236	4262018***	[Q]R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.04094	-118.45245	pv2install roof mounted pv system sized 23.1kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40885	13041-10000-35517	7431 N TOPEKA DR	91335	3	186B121   533	2104015019	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.20577	-118.54634	PV1, Install 4.5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (18) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40886	19041-20000-28709	13161 W LUMINA WAY	91401	2	180B157  1188	2326021055	(Q)RAS3-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Re-Activate Permit	08/19/2020 12:00:00 AM	ADDRESS	34.18703	-118.41993	new sfd 600 amp service.  plan chech for power only.  permit fees paid under building combo permit 16010-10000-02908	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40887	17041-20000-42135	6740 S BRYNHURST AVE	90043	8	102B185   488	4006022018	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Apartment			11/21/2017 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.9769	-118.33366	new apartment building 600 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40888	15041-10000-23989	2017 N ARGYLE AVE	90068	4	151-5A189 412	5586005009	R3-1XL	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.10746	-118.32543	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20KW INTERCONNECTED WITH MSP.(84) QCELL MODULES Q.PRO-G3 255-265(2) SUNNY BOY 10000 TL INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40889	19041-10000-43244	1010 S KENMORE AVE	90006	1	129B197   259	5078014023	C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	04/13/2021 12:00:00 AM		Issued	04/13/2021 12:00:00 AM	ADDRESS	34.05234	-118.29671	FULL PC FOR A NEW  MIXED USE BUILDING, SCOPE OF WORK INCLUDES (1) 4000A (120/208 3P, 4W) SERVICE FEEDING HOUSE PANELS, LAREGE EQUIIPMENT AND  SIX DISTRIBUTION METER CENTERS THAT SUBFEEDS 126 SUBPANELS (DWELLING UNITS) WITH A  TOTAL LIGHTING  AREA OF  89,274 SQFT. PER BUILDING APPLICATION: ((NEW ___ X___ 7 STORY MIX USE 126 UNIT APARTMENT BUILDING. 1 STORY RETAIL (6000 SF). 5 LEVELS OF TYPE IIIA CONSTRUCTION OVER 2 LEVELS OF TYPE 1 CONSTERUCTION WITH PARKING GARAGE ON 1ST LEVEL AND 2 LEVELS SUBTERRANEAN PARKINGB#19010-10000-03306))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40890	17041-20000-40106	23838 W BURBANK BLVD	91367	3	174B089   555	2047010018	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.17064	-118.64664	pv1install roof mounted pv system sized 10kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40891	15041-10000-03515	4815 S STAUNTON AVE	90058	9	111A213    11	5106009047	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.00012	-118.2422	Title 24 plan check only.  Total area = 3,372 sq. ft.Remove HID lights and replace with LED light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40892	12041-20000-17016	4700 S CENTRAL AVE	90011	9	112-5A209 316	5107016001	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Apartment			07/20/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	08/07/2012 12:00:00 AM	ADDRESS	34.00099	-118.25628	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40893	18041-20000-45289	17161 W SUPERIOR ST	91325	12	201B133   401	2692013020	RA-1-H	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Issued	11/28/2018 12:00:00 AM	ADDRESS	34.24678	-118.50759	Plan check for PV roof mounted system, system size: 10.57kW DC, 10.31kW AC CEC with 34 modules and 34 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40894	19041-20000-45890	10926 N OWENSMOUTH AVE	91311	12	210B105   165	2722004029	RE40-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.26887	-118.60215	PLAN CHECK FOR NEW 27 KWH ESS SYSTEM. SCOPE OF WORK CONSISTS OF (2) 5 KW BATTERIES A 125A LOAD CENTER AND A 200A DISTRIBUTION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40895	13041-20000-26227	5130 W EDGEWOOD PL	90019	10	132B181  1116	5084021013	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.05451	-118.34283	EXISTING BUILDING. CHANGE OF USE. PC FOR COMPLETELY NEW ELECTRICAL SERVICE AND BUILDING WIRING. PC FOR POWER AND ENERGY. ART GALLERY. NEW 1200A SERVICE. LOCATION IN METHANE ZONE. CLASSIFIED LOCATION. NEW UPS. TOTAL AREA 11895 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40896	14041-10000-04191	8744 W 3RD ST	90048	5	138B169   561	4334011036	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.07339	-118.38317	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO CHANGE OF USE FROM (E) RETAIL TO (N) RESTURANT.1195 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40897	17041-20000-14322	10315-10317 N ZELZAH AVE	91326	12	204B129   148	2731010027	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.25786	-118.52352	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT of retail space into dining room/restrooms (995 sf) and combine with (E)adjancent restaurant . 1770 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40898	16041-10000-22869	1264 E 25TH ST	90011	9	118-5A211 384	5119023003	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.0175	-118.24993	PV 1 roof mounted solar system installation to a single family home. (1) new central inverter rated at 3.8 kw and 13 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40899	18041-20000-19110	1750 N VINE ST 10th Floor	90028	13	148-5A189   4	5546030028	(T)(Q)C2-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.10311	-118.32649	Plan check for Title 24 only. Project site is the 10th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,013 sq. ft.Note: Building application has been generated under 18016-10000-12520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40900	17041-10000-05821	6100 W WILSHIRE BLVD	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.06282	-118.36187	PC for indoor title 24. Removing HID fixtures and replacing them with new LED ones. Area: 144,350.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40901	14041-10000-13857	3609 N CROWNRIDGE DR	91403	5	159B141    41	2280013023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.13594	-118.47553	Inspector to verify subpanel bus size is 120A. PV1 9.288KWAC. 240V. microinverter. STD. ???story. Roofmount. [(43) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(43)modules: {LG 270 S1C-A3}].	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40902	14041-10000-13105	16333 W MIDWOOD DR	91344	12	216B137   405	2605010022	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.28645	-118.48754	PV1 ROOF MOUNTED MICROINVERTER. TOTAL SYSTEM SIZE 2.7KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40903	14041-20001-10139	20300 W TAU PL	91311	12	207B113   245	2707017015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.2609	-118.57574	EXXPEDITE PER APPLICANT REQUEST(((NEW SYSTEM DESIGNRoof mounted PV system with size 4.75KWdc.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40904	13041-10001-19489	7449 N CALVIN AVE	91335	3	186B117   464	2116016043	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.20606	-118.55584	changes to approved set of plans: added note per inspector showing that AC disconnect and solar load center is not  being installed. PLAN CHECK ONLY IN REFERENCE TO APPLICATION NUMBER 13041-20000-16583. PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. SYSTEM SIZE IS 7.350 KWDC. [MODULES: TRINA SOLAR # TSM-245PC/PA05 |||| INVERTER: FRONIUS # IG PLUS V7.5] PERMIT TO BE PULLED FOR THE DIFFERENCE UNDER A SEPERATE APPLICATION NUMBER: 13041-10001-16583.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40905	19041-20000-15889	10420 N VANALDEN AVE	91326	12	207B121   841	2728018015	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.26002	-118.54891	Plan check for PV roof mounted system, system size: 5.25KW with 15 PV Modules and 15 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40906	10041-20000-15681	9121 N OAKDALE AVE	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.23622	-118.56725	Plan check T-24 Energy for office TI. Existing wiring. Relocate light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40907	14041-10001-25394	6240 E YORK BLVD	90042	14	153A231   440	5492034008	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.11486	-118.18317	Changes to approved set.  Delta-3 revisions only.  Changes to trellis lighting design.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40908	05041-10001-01464	1601 S PERRINO PL	90023	14	118-5A219 167	5169015011	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Issued	04/02/2013 12:00:00 AM	ADDRESS	34.02019	-118.2225	IN ORDER TO INSTALL  A  PV SYSTEM ON THE ROOF OF BLDG B, A SIMILAR SWBD IS INSTALLED TO ACCOMODATE FOR THE POINT OF CONNECTION OF THE PV  SYSTEM TO THE UTILITY. NEW SBD IS THE MAIN SWBD AND THE OLD SWD IS USED AS A DIDTRIBUTION BOARD. LOADS ARE THE SAME. ((((((((ELECT PLAN CHECK AND PERMIT FOR MULTI METERING SERVICE UPGRADE AND NEW LTG FIXTURES IN NON-CONDITIONED TITLE-24 EXEMPT BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40909	13041-10001-12670	14220 W VALLEY VISTA BLVD	91423	4	165B153  1026	2274018001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2013 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	PIN	34.14460292	-118.44312058	plan check only. changes to approved set of plans. removing a module and changing the tie-in method - supply side connection for main panelboard with multiple disconnects. PV1 24.25KW ROOFMOUNT SOLAREDGE OPTIMIZERS NONSTANDARD PLAN. {inverters se6000A-US( 3x) se5000a-us (1x) } .{ trina modules TSM-245PC05 (98x)}. 2 story house. New main panel permit number is 13041-10000-20010.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40910	18041-10001-39888	1920 S MORAY AVE	90732	15	012B193   886	7562013011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	Yes	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2018 12:00:00 AM			PC Approved	11/19/2018 12:00:00 AM	ADDRESS	33.72702	-118.31248	PLAN CHECK FOR CHANGES BASED ON FIELD INSTALLED. SCOPE INCLUDES CHANGE IN ROOF LAYOUT AND MCB DERATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40911	13041-20000-35740	11510 N VALJEAN AVE	91344	12	213B137   558	2605022017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.2797	-118.48663	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5KWAC. 21 MODULES AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40912	15041-10000-14773	9901 W WASHINGTON BLVD 101	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.02174	-118.39786	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT 1686 SQRFT RESTAURANT ON AN EXISTING 1600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40913	10041-20000-25710	6834 W HOLLYWOOD BLVD	90028	13	148-5A185 161	5548006015	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	ADDRESS	34.10138	-118.33965	Plan check for replacing (2) 600A fused switches to new location from exterior location to interior electrical room for Jimmy Kimmel Live show.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40914	11041-10001-21895	808 W 58TH ST	90037	9	108B197  1393	5001015032	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Expired	02/10/2015 12:00:00 AM	ADDRESS	33.98934	-118.28723	Modification to previously approved set of plans for Delta G changes only to tap panel MS2, remove one sub-panel and change the equipment load for x-ray.                  <<<<<PLAN CHECK POWER AND ENERGY FOR TI OF EXISTING MEDICAL BUILDING. TWO EXISTING 600A AND 1000A SERVICES SUPPLYING BUILDING.  Building is not State Licensed, NOT CHECKED FOR OSHPD.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40915	16041-10000-23762	725 S FIGUEROA ST 33RD FLR	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR ENERGY.T.I. FOR OFFICE ON 33RD FLOOR ONLY.  IMPROVEMENT WORK ON 1,764 SQ.FT AT EXIST. CORRIDOR. NEW CEILING, LIGHTING, AND FINISHES.SCOPE OF LIGHTING AREA 1717 SQ FT.B#16016-10000-07676	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40916	18041-20000-20347	8800 N WHITE OAK AVE	91325	12	195B129   328	2768013016	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	07/05/2018 12:00:00 AM	ADDRESS	34.23064	-118.51985	Plan check for PV roof mounted system, System size: 11.4kWac with 40 modules and 1 inverter(11.4kW) in SFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40917	13041-10000-27125	2130 N PRINCETON AVE	90026	13	144A211   119	5420036016	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.0899	-118.24872	PV1 PLAN CHECK ROOF-MOUNTED  2.96KW DC PHOTOVOLTAIC SYSTEM WITH TRANSFORMERLESS INVERTER (13) MODULES: kyocera #kd220gx-lfbs(1)SOLAREDGE #SE3000A-US(13)SOLAREDGE #OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40918	19041-10000-45855	1363 N ST ANDREWS PL	90028	13	147A193   156	5544030052	R4-2	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	01/13/2021 12:00:00 AM		Permit Finaled	07/27/2023 12:00:00 AM	ADDRESS	34.09598	-118.31113	POWER PLAN CHECK FOR A NEW 800A SERVICE TO REPLACE EXISTING SERVICE. SCOPE INCLUDES NEW SERVICE SWITCHGEAR AND EQUIPMENT. NO NEW LOAD PROPOSED, ALL EXISTING SUB-PANELS TO REMAIN.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40919	12041-10001-30008	380 W WORLD WAY level 3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	delta changes to previuosly approved set.  A SUB PANEL  AND CIRCUITS WERE ADDED AND LOADS FOR DISTRIBUTION BOARDS ARE UPDATED Recalculate fees since applicant brought check.FULL POWER AND ENERGY. LAX. storage for the DUTY-FREE shops (Unit # 3s2-07C-G). 1ST TIME TENANT.  Located on level 3 back of the house. Methane. Separate fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40920	13041-20001-05098	3615 E LAVELL DR PV-1	90065	14	151-5A217  58	5460011056	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.11102	-118.22895	PV-1. Plan check for micro-inverter standard plan. 1.505kW combined total. Zoning has been cleared on original permit, 13041-10000-05098.PV SOLAR - 7 PANELS AND 1 INVERTER.  1.78KW - 135 SQ.FT Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40921	19041-10000-08527	4121 W SANTA MONICA BLVD	90029	13	145-5A201 383	5429002026	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.09205	-118.28241	pc for FA  new two-story commercial building with one level basement .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40922	19041-10000-31462	4144 S KENYON AVE	90066	11	108B157    94	4231018005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/16/2019 12:00:00 AM	ADDRESS	33.99578	-118.42875	[EPLAN]PLAN CHECK FOR NEW ESS(TESLA POWERWALL) CONNECTED TO EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40923	18041-20000-21373	10015 S WESTERN AVE	90047	8	091-5A193  97	6058006013	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Closed	03/23/2023 12:00:00 AM	ADDRESS	33.94488	-118.30921	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40924	13041-20000-36067	4275 S HOBART BLVD	90062	8	114B193  1316	5021024027	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.0053	-118.30795	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 1.72 KW AC USING MICROINVERTERS. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40925	13041-20000-35120	800 W WILSHIRE BLVD SUITE 450	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.0493	-118.25841	TI FOR OFFICE SPACE. SCOPE OF WORK ON SUITE 450 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40926	11041-10000-25126	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	New feeder, TFR, and panels for future T> I. space #100 (over 400A device)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40927	12041-20000-26337	21326 W VENTURA BLVD	91364	3	171B105   117	2167002003	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM			Corrections Issued	11/02/2012 12:00:00 AM	ADDRESS	34.16748	-118.59662	Change to lighting only on existing circuits.  No new load per applicant.  PLAN CHECK ONLY for T-24 with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40928	18041-10000-02551	2721 E 11TH ST	90023		120A221    81	5170027004							Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.02312	-118.21926	PC for T24 only for indoor and outood lighting for office TI. Installing two new panels, lights, receptacles and eqipment. B# 17014-10000-06184. Total area 10282.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40929	18041-10000-31593	14663 W KESWICK ST	91405	6	189B149   576	2210025009	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.21048	-118.45307	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40930	17041-10000-44073	731 S BROADWAY	90014	14	127-5A209  68	5144014032	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.04456	-118.25423	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 69 FA DEVICES, AND TWO FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40931	14041-10000-18031	1022 S SIERRA BONITA AVE	90019	4	132B177   844	5085004005	R1-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.05676	-118.3561	PV1, INSSTALL 7.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(27) MODULES: LG SOLAR LG265S1C-A3(27) MICRO INVERTER: ENPHASE M215-60-2LL-SX-IG 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40932	12041-20000-05077	18706 W HATTERAS ST	91356	3	174B121    46	2156021023	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	ADDRESS	34.17702	-118.54111	fire alarm system preschool	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40933	10041-10000-15644	17323 W VENTURA BLVD	91316	5	171B133   685	2257016056	(Q)C4-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Public Safety Only			08/11/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.16115	-118.51065	NEW FIRE WARNING SYSTEM FOR A 3-STORIES COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40934	10041-10000-14724	11400 S FIGUEROA ST	90061	8	087A201   308	6088004028	C2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM			PC Info Complete	08/11/2010 12:00:00 AM	ADDRESS	33.93079	-118.28234	TENANT IMPROVEMENTS IN A JACK-IN-BOX RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40935	15041-30000-39700	6454 N LANGDON AVE	91406	6	180B145   631	2234015008	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.18832	-118.46899	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 8.6 kWac.  Two inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40936	17041-30000-09099	2049 S CENTURY PARK EAST 5th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is the common area corridors on the 5th floor of an existing commercial building. Project scope is lighting. Total lighting area = 1,700 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40937	14041-20001-05203	12809 W NORTH SEAGLASS CIR	90094	11	102B161  1224	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	33.97502	-118.41801	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40938	18041-20001-17332	6927 N REMMET AVE Unit A	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			07/23/2018 12:00:00 AM			PC Approved	07/23/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	Revision to approved set of plans.  Change of inverter from ABB-PVI-3.6-OUTD-S-US-Z-A to ABB UNO-DM-3.3-TL-PLUS-US-SZ-RA.(((Plan check for a PV2 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (15) modules. Service size is 400 Amps.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40939	16041-10000-19374	11800-11818 W WILSHIRE BLVD	90025	11	129B145   804	4263007123	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.04771	-118.46271	PC for existing fire alarm system. Scope inclucdes replacing the fire alarm panel and annunciator. The fire alarm system is for an existing medical clinic.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40940	15041-20000-17855	11300 W SANTA MONICA BLVD	90025	11	129B149   496	4261009035	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.04628	-118.44855	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT TO EXISTING RETAIL SPACE. 1400 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40941	13041-20000-35425	9133 W ORIOLE WAY	90069	4	147B169   785	5560006012	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	05/02/2014 12:00:00 AM	ADDRESS	34.09669	-118.38927	Plan check for power, single family dwelling. 600A service. New building. 8000sqft house. PC only. permit issued under original application under building combo permit. inspector to field verify if additional inspection fees required	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40942	16041-10000-14346	1270 S GRANVILLE AVE	90025	11	129B145   955	4263008***	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Apartment			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.04642	-118.46103	UPGRADING FA PANEL AND ADDING 11 MINI HORNS, 5 BELLS AND 1 HEAT DETECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40943	14041-10000-09384	236 S LOS ANGELES ST 1-176	90012	14	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			04/09/2014 12:00:00 AM			PC Info Complete	04/22/2014 12:00:00 AM	ADDRESS	34.04922	-118.24386	Revision of the single line diagram and addition of pannels and non-dwelling power equipment branch circuits.  These entail additions to previously approved set of plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40944	11041-20000-18957	11042-11044 W MAGNOLIA BLVD	91601	2	171B173   608	2353006013	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM			Corrections Issued	09/07/2011 12:00:00 AM	ADDRESS	34.16478	-118.37201	Retail space remodelT-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40945	13041-20000-24479	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	RENOVATION OF SMALL ELECTRICAL ROOM. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 292 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40946	12041-20000-03877	21318 W DUMETZ ROAD	91364	3	168B105   468	2172001026	C1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.15749	-118.59513	Complete remodeling of the existing building A.  New 800A service, panels, and branch circuits.  Note: The only work at building B is replace outdoor lights.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40947	14041-10000-16409	1150 S BEVERLY DR	90035	5	132A167   103	4330031040	C2-1VL-O, R4-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM			PC Approved	07/09/2014 12:00:00 AM	ADDRESS	34.05621	-118.39569	PLANCHECK FOR T24 ENERGY. CORRIDORS FOR MARRIOT HOTEL BEVERLY HILLS ( LEVELS 3-12). 14950 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40948	18041-10000-34030	5948 S MAIN ST	90003	9	105B205   320	6006001019	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	33.98618	-118.27374	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40949	19041-10000-22858	1581 W ADAMS BLVD	90007	8	123B197   854	5054017015	C1-1L-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Apartment			06/14/2019 12:00:00 AM			PC Info Complete	12/05/2019 12:00:00 AM	ADDRESS	34.0329	-118.29686	FULL PLAN CHECK FOR A NEW 3-STORY APARTMENT UNIT BUILDING (TOWNHOUSES. 7 UNITS). SCOPE INCLUDES (2) SERVCIE, 120/240V SINGLE PHASE WITH A TOTAL LOAD GREATER THAN 700-AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40950	17041-10000-00662	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.01303	-118.24279	PC FOR T24 ENERGY ONLY. PROVIDE NEW LIGHTING AND OFFICE TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40951	15041-10006-06920	1516 N SAN PABLO ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.06268	-118.20282	Changes to approved set.  Addition of 4 new IT/telecom rooms and upsize of HVAC units.  Changes under delta W1     Core & shell for new 5 story medical building includes power & energy and OSHPD 3 PLAN REVIEW was approved under 14041-10000-29044	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40952	16041-10001-41703	18110 W NORDHOFF ST #b	91325	12	198B125   301	2769010016	C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.23529	-118.52783	Plan check for Title 24 only in existing space restauraunt T.I. Total area: 1070 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40953	19041-20000-14650	22940 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.18624	-118.62623	Interior alteration of (E) retail store.  New receptacles, general and valence/display lighting.  Title 24 plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40954	18041-20000-31775	9301 N TAMPA AVE #47	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.2392	-118.55379	ti to an existing cmmercial space.  adding new lighting new controls to new panel.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40955	16041-10000-04372	1248 S MANHATTAN PL	90019	10	129B193  1174	5080005007	R1-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.048	-118.31	PV1, ROOF MOUNTED SOLAR SYSTEM TYING INTO AN EXISTING 3.0KW SYSTEM. SCOPE INCLUDES ADDING (10) NEW MODULES AND (1) NEW 3.0KWac INVERTER.  TOTAL SYSTEM SIZE IS 6.0KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40956	10041-10000-06665	6464 W SUNSET BLVD	90028	13	147A187   158	5547026001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Public Safety Only			04/13/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	04/20/2010 12:00:00 AM	ADDRESS	34.09782	-118.33125	REPLACING THE FIRE ALARM PANEL TO AN ADDRESSABLE TYPE COMPATIBLE WITH THE DEVICES THAT ARE INSTALLED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40957	15041-20002-19438	225 N VERMONT AVE	90004	13	138B197   568	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			07/10/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.07529	-118.29188	[[[[7/10/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 5 CHANGES ONLY.  UPGRADING  INVERTER  INV-M TO 30KVA AND INV-L TO 25KVA. ADDITION OF 5 LANSCAPING CIRCUITS.]]]]]PLANCHECK FOR POWER AND ENERGY. NEW APARTMENT.  4-story �55' tall mixed-use apartment type VA over basement parking type 1A. 100 residential units , approximately 4500 sf of retail, and 112 parking stalls. METHANE ZONE.  fIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40958	18041-20000-33531	1533 S SELBY AVE 1-6	90024	5	132B153   910	4325028010	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	09/16/2021 12:00:00 AM	ADDRESS	34.05466	-118.43755	Renovation of (E) 6-unit apartment building.  600A 240/120V 1ph-3w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40959	14041-20000-21959	6901 N TUJUNGA AVE	91605	2	183B173   184	2320002016	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.19626	-118.37921	PV2.  Install 192 kw roof-mounted, utility-interactive solar system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40960	17041-10000-40898	300 WORLD WAY SUITE 342	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC for T24 only for sign lighting. Installing two new sign lights in concession areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40961	09041-20001-08271	13751 W SHERMAN WAY	91405	2	183B153    13	2216034019	(T)(Q)R3-1, (T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.01	Electrical	Electrical	Apartment			07/01/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.20139	-118.43276	REVISION TO APPROVED PLANS. RELOCATE FACP, RPS, DEVICES, AND ADD DEVICES.FIRE ALARM SYSTEM FOR  52  UNIT MULTI-FAMILY AFFORDABLE HOUSING APTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40962	16041-10001-28773	20333 S NORMANDIE AVE	90501	15	054B197    45	7351020021	M2-1VL, PF	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	33.84604	-118.29972	PC FOR CHANGES TO APPROVED SET MARKED UNDER DELTA 5. SCOPE INCULDES NEW PULL SECTION BY DWP WHICH RESULTED IN NEW ROUTING FOR SERVICE ENTRENCE CONDUCTORS.THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40963	16041-20001-32785	6646 N BECK AVE	91606	2	180B169   394	2320023004	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Apartment			02/21/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.19159	-118.38327	(2/21/217)changes to an approved set of plans.  changes include reduction of (2) pv modues and reconnect to main residence panel.Plan check for installation of roof-mounted solar array on triplex for single unit. Interconnect with 100A service. 2.88kW ungrounded system. (12) EnPhase M250 microinverters. (12) 285W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40964	14041-20000-28570	16914 W SAN FERNANDO MISSION BLVD	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.27132	-118.50028	TI TO AN EXISTING COMMERCIAL BUILDING SINGLE STORY.  RELOCATING/ADDING LIGHT FIXTURES.  USING EXISTING POWER EQUIPMENT.  1001SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40965	19041-20000-50288	110 E 9TH ST 6th Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TI to commercial tenant spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40966	08041-10001-14552	2142 S PONTIUS AVE	90025	5	126B153   755	4322025041	M2-1VL	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	08/13/2012 12:00:00 AM	ADDRESS	34.04026	-118.43869	Change service class from 208/120V 3 ph to 480/277V 3 ph, add panels, transformers and circuits to the 480V side.((((Electrical installation for new 3-story office building + 2 subterranean parking garages. New 120/208V 3ph 4W 2000A Service. EPC: Power and Energy(T-24).))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40967	14041-20000-30761	14955 W DICKENS ST 1-18	91403	4	166-5A147  52	2276004011	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			11/05/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.15153	-118.45925	PV2Install roof-mounted solar array on Apartment building. Interconnect with 125A subpanel. (400A main service).System size: 10kW. Grounded system. 32  305W pv modules across 4 strings (8+8+8+8).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40968	14041-10001-16309	4508 W WAWONA ST	90065	14	160-5A219 217	5683019020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.13351	-118.22579	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. SYSTEM SIZE 5.23 KW.(19) SOLARWOLRD SW275 MODULES(19) M250 MICROINVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40969	19041-10000-25977	7731 N HAYVENHURST AVE B	91406	6	189B137   123	2205009092	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.21159	-118.49261	FULL PLAN CHECK CHANGE OF USE FROM WAREHOUSE TO WAREHOUSE/MANUFACTURING AND RETAIL.  AREA OF SCOPE IS 22,700SF. EXISTING SERVICE SIZE IS 600A, 277/480V, 3PH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40970	14041-20000-30991	13449 W CREWE ST	91405	2	183B157   588	2328016006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.19676	-118.42633	pv1central string inverter standard plan system sized 8.8kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40971	13041-20000-32120	5608 N VAN NUYS BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.1725	-118.44837	Change to lighting in an existing restaurant.  Occupancy load is less than 400 amps, electrical load is less than 400 amps per applicant.  PLAN CHECK ONY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40972	14041-10000-11141	649 N NORTH BROADWAY	90012	1	133-5A215 147	5408016016	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Public Safety Only			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.05987	-118.23972	new fire warning system with central station monitoring for commercial bldg;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40973	12041-10000-11453	12181 W BLUFF CREEK DR Suite 101-5th Floor	90094	11	102B161  1150	4211010061	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM			PC Approved	06/01/2012 12:00:00 AM	ADDRESS	33.97788	-118.40638	T.I. to an existing 27.644 sqft,  5-story office building.  Work is on the 5th floor.  Change to lighting, new transformer, panels, circuits, loads etc.  Load is less than 400 amps, per engineer of record.  PLAN CHECK ONLY for Energy, with Emergency lighting.  (Per Engineer of Record's agent the entire building is Suite 101)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40974	14041-20001-00634	23255 W ARMINTA ST PV1	91304	12	189B093   419	2020024004	RE11-1	South Valley		West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			Reviewed by Supervisor	01/21/2014 12:00:00 AM	ADDRESS	34.21337	-118.63435	EXPEDITE FEES ONLY.      <<<New ungrounded PV System for an existing single family dwelling with two inverters.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40975	12041-20000-17983	1513 S GRAND AVE	90015	14	124-5A207 123	5134015027	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.03622	-118.26632	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40976	13041-10000-32263	6062 N SHADYGLADE AVE	91606	2	177B165   510	2333015001	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Expired	02/08/2016 12:00:00 AM	ADDRESS	34.1812	-118.40182	PV1, Install 4.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 17 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40977	12041-10000-12415	111 E UNIVERSAL HOLLYWOOD DR 12TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING EXISTING FLOOR HAVING OFFICES; NEW LOAD IS LESS THAN 400 AMPERES.PLAN CHK IS FOR TITLE 24 AND 1 EACH EMERGENCY LIGHT; ON 12TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40978	14041-20000-26570	21220 W MAYALL ST	91311	12	204B105   654	2747013038	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Expired	10/20/2016 12:00:00 AM	ADDRESS	34.2535	-118.59483	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW.(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(19) SolarEdge P300 power optimizers(19) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40979	14041-10000-21382	680 S BERENDO ST	90005	10	132B197   130	5094008010	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.06064	-118.294	INSTALLATION OF A NEW FIRE ALARM SYSTEM. APARTMENTS. 1 FACP, 6 POWER SUPPLIES AND 503 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40980	16041-20000-04737	9537 N TEXHOMA AVE	91325	12	201B129   394	2755009026	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.24447	-118.51678	Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (3) inverters, (50) modules, and (1) load center.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40981	17041-10000-36727	7007 S DENVER AVE	90044	8	102B201   650	6013024021	R2-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Issued	11/07/2017 12:00:00 AM	ADDRESS	33.97586	-118.2839	PC FOR ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE 10KWAC / 10.45KWDCSCOPE INCLUDES:38 MODULES WITH OPTIMIZERS SINGLE INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
40982	18041-20000-07722	521 N GRAMERCY PL	90004	4	141B193  1075	5522014014	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			03/02/2018 12:00:00 AM			Reviewed by Supervisor	04/11/2018 12:00:00 AM	ADDRESS	34.08091	-118.31275	New 19-unit 4-story apartment building.  800A 208Y/120V 3ph-4w service.  Building permit under 17010-20000-02344.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40983	14041-20000-35605	5700 W WILSHIRE BLVD suite 120	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	Plan check for Title 24 energy. Offices no change in occupancy. TI. Suite 120. Sqft 6504. Newly connected load less than 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40984	18041-20000-24185	2131 W JEFFERSON BLVD	90018	10	120B189   655	5052007007	C2-1VL-O-HPOZ-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.02569	-118.31858	Plan check for Title 24 Energy only in existing space T.I. new lighting and receptacle. Total area: 2429 sq ft. B#18016-20000-19272	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40985	17041-10000-45717	221 E D ST	90744	15	030B209   862	7418012025	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	33.77442	-118.25995	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
40986	15041-30000-41251	333 S HOPE ST Suite E100	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	Title 24 plan check only.  Total area = 6,029 sq. ft.    T.I. to section of ground floor in existing commercial highrise.  Remodel of refridgerated wine storage area.  New lighting, receptacles, and compressors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40987	18041-10000-46935	1331 S VERMONT AVE	90006	1	129B197  1235	5075001008	RD1.5-1, [Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Closed	01/26/2024 12:00:00 AM	ADDRESS	34.04633	-118.29181	PC FOR POWER AND ENERGY FOR A TI. NEW 600A SERVICE, T24, TOTAL SQ FT 4308.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40988	12041-20000-05113	19950 W RINALDI ST	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			Corrections Issued	03/06/2012 12:00:00 AM	ADDRESS	34.27535	-118.56939	Porter Ranch Pharmacy t.i.Energy onlyexist. permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40989	14041-20001-23693	7228 N AMIGO AVE	91335	3	183B121  1185	2118028008	(T)(Q)R3-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			01/27/2016 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.20195	-118.53846	01-27-16 Change to approved set of plans. Changes include main fuse to breaker (65kAIC series rated ), some of feeder conductor and conduit size modified. Changes apply to delta 1 only. {{{{{{NEW TYPE V-A 22 UNITS 3-STORY W/ TYPE I-A  BASEMENT GARAGE APT BLDG.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40990	14041-20001-00054	18725 W SHERMAN WAY	91335	3	183B121    99	2118026018	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.20128	-118.54148	Change from retail to adult daycare.  Install new panel, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40991	11041-20000-24158	20277 W VIA SANSOVINO	91326	12	219B113   271	2701061011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.29709	-118.5754	solar single family 5.16 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40992	15041-10001-06356	11243 N CHIVERS AVE	91331	7	210B165   228	2532031027	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	34.27407	-118.40508	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40993	16041-10001-36519	850 S HOPE ST roof ameni-ties	90017	14	129A209   239	5144020020	[Q]C4-4D	Central		Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.04528	-118.25988	This is plan check only, permit is covered under master plan. Changes to approved set noted as Delta-8, scope includes:1> Add (1) 100A panel for emergency lights with its circuits2> Revise homerun for the emergency lights to connect to the new panel3> Increase transformer size feeding the new EM. panel from 5kVA to 15 kVA4> Remove a feeder from INV1 to LCPT24 information remain the same.<<Plan check for power and energy.  Buildout of rooftop amenity deck on 7-story lowrise parking garage which serves adjacent apartment building.  Place of assembly.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40994	16041-20005-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM			PC Approved	01/22/2018 12:00:00 AM	ADDRESS	34.04771	-118.46271	PC FOR CHAGNES TO APPROVED SET UNDER DELTA 12. CHANGES INCLUDES ADDITION OR CIRCUATION PUMP AND WATER HEATER TO EXISTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40995	19041-20000-41524	129 N ROCKINGHAM AVE	90049	11	132B137   318	4406001020	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Info Complete	01/08/2021 12:00:00 AM	ADDRESS	34.05852	-118.49146	Permit fees under Combo building permit, B# 19010-30000-01470. PLAN CHECK ONLY TO A (N) 2-STORY S.F.D. SCOPE OF WORK INCLUDES NEW 600 AMP SERVICE AND PANEL, 120/240V, 1PH. PERMIT TO INCLUDE 600 AMP SERVICE, PANEL AND GENERATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
40996	16041-10001-13654	762-788 S KOHLER ST	90021	14	124-5A213 244	5146006006	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.03587	-118.24383	Changes to an approved set of plans. All changes are made under delta 1. Changes include adding new exterior lights for canopy. ((((TI to an (E) commercial build. install light fixtures on the outdoor canopy.  PC for T-24 only. Total area: 2,424 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40997	17041-10000-04549	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	Plan check for Title 24 only in existing space T.I. Newly connected load is less than 400A . Total area: 4,550 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
40998	14041-10000-13862	3930 S DENKER AVE	90062	8	117B193  1526	5036022018	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Expired	07/08/2016 12:00:00 AM	ADDRESS	34.01394	-118.30441	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
40999	19041-10000-17583	849 N ALAMEDA ST	90012	14	132A215    43	5408011908	PF-1VL	Central	Central City	Historic Cultural North		2071.02	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.05756	-118.23746	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41000	10041-20000-01290	837 S BLOOM WALK	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/25/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Expired	09/07/2012 12:00:00 AM	PIN	34.02192429	-118.28551249	Tenant improvement for 2nd Floor restrooms at Donald P. and Katherine B. L.H.I. bldg on USC Campus.  Title 24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41001	11041-20000-18539	12800 W CULVER BLVD #NOC 561	90066	11	105B157   410	4221031009	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	33.98489	-118.42552	T.I.  Remodel of light fixtures in room # NOC 561.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41002	19041-20001-28719	4549 N CARPENTER AVE pv1	91607	2	168B169   915	2364006030	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.15351	-118.39115	expeditepv1install roof mounted pv system sized 15.2KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41003	17041-10000-45641	333 S GRAND AVE STE 4450	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR INTERIOR OFFICE T.I. FOR TITLE 24 ENERGY ONLY IN A HIGH RISE BUILDING.  SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTING.TOTAL AFFECTED AREA 7489 SQ.FT.B#17016-10000-35981update engineer on record.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41004	19041-10000-29132	11574 N SEMINOLE CIR	91326	12	213B117   122	2822023013	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.28266	-118.55649	Plan check for a 11.4KW AC / 13.3KW DC roofmounted system with (1) inverter, (38) modules and optimizers interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41005	19041-20000-44013	4927 N TARZANA WOODS DR	91356	3	168B117    99	2175038011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Issued	10/28/2019 12:00:00 AM	ADDRESS	34.15956	-118.5616	PLAN CHECK FOR PV SYSTEM, SYSTEM SIZE IS 19.8 KW DC/18.9 KW AC, SCOPE OF WORK INCLUDES 60 PV MODULES WITH MICROINVERTERS AND A NEW LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41006	12041-20000-24229	424 N ARDEN BLVD	90004	4	138B189    79	5523019005	R1-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.07818	-118.32585	PV INSTALLATION IN SFD. REGULAR PLAN CHECK. 21 MODULE. 7KVA INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41007	18041-10000-01503	834 S BROADWAY	90014	14	127-5A209 189	5144016061	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.04284	-118.25532	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 3200 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41008	13041-10000-29517	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	"Plan check for temporary installation for switchboard ""1DTH"" to be connected to ""1DPH"" while 2HPJ3 under construction. See plan check for #12041-10002-07640 for approved final installation."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41009	15041-10000-13939	600 WORLD WAY TERM 6-# 621	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	addition of 3 ckts for receptacle loads in storage area. Does not require plan check but plan check required by client.Lighting system will remain the same	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41010	17041-10001-07582	16665 W ARMINTA ST	91406	6	189B137    28	2205009030	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.21497	-118.49677	CHANGES TO APPROVED SET. CHANGES CLOUDED ON PLANS. CHANGES INCLUDE USE OF LED TYPE LIGHT FIXTURE. UPDATED T24 CALCS AND PHOTOMETRICS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41011	16041-10001-22691	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Closed	08/22/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA DCN-003 ON PLANS. CLOUDED. CHANGES INCLUDE INCREASE SIZE OF UPS AND REVISED FLOOR PLANS. NO CHANGES TO T24 POWER ALLOWANCE AND INSTALLED WATTAGE. PLAN CHECK FOR NEW FLOOR PLAN LAYOUT ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41012	18041-10000-13489	3550 W WILSHIRE BLVD	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Issued	04/12/2018 12:00:00 AM	ADDRESS	34.06157	-118.30226	Installation of a 600A switchboard supplied from a service ( 17041-10000-38257) to provide temporary construction power. Permit for the circuits are not on this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41013	19041-10000-35375	2913 W EXPOSITION PL Units 4	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02048	-118.32811	Plan check for a PV2 2.56kw DC / 3.0KW AC roofmounted system. Scope includes (8) modules and (1) inverter interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41014	11041-10000-27602	5838 S VERMONT AVE	90044	9	108B197  1460	6004001023	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00, 2371.00	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM	01/12/2012 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	33.98843	-118.29128	T-MOBILE SITE NO SUITE NO.  T.I. to existing building.  Install general/emergency lighting in sale area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41015	16041-10000-24518	5008 N FIGUEROA ST	90042	1	150A225   236	5468005044	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.10503	-118.20159	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW INTERIOR AND EXTERIOR LIGHTS. TOTAL AFFECTED AREA IS 4043 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41016	19041-10000-37426	1269 S COCHRAN AVE	90019	10	129B181   293	5085014036	C1-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM			PC Approved	09/27/2019 12:00:00 AM	ADDRESS	34.05198	-118.35133	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI FOR AN EXISITING OFFICE SPACE, SCOPE OF WORK INCLUDES NEW LIGHTING, AND CONTROLS. TOTAL AFFECTED AREA IS 3055 SQFT. NOTE PERMIT FEE HAS BEEN PAYED UNDER 19041-70000-21727B#: 19016-20000-05254	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41017	18041-10000-06917	10628 N HALBRENT AVE	91345	7	207B145   407	2649009002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.26333	-118.46542	Install new rooftop solar on SFD, 3kW AC system. (13) modules with (13) P320 optimizers, (1) inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41018	15041-20000-31509	7900 N NELSON ROAD Suite B	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.21499	-118.4422	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,012 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41019	14041-20001-24834	7010 S HOOVER ST Unit #3	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #3. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41020	11041-10000-26750	810 S SPRING ST	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.04268	-118.25375	Electrical work for a TENANT LEASE SPACE.  Adding new panels, 4 transformers, lighting, and receptacles and wiring to safety switch for future AC unit.  PLAN CHECK ONLY for Energy, with Emergency lights.  No suite number	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41021	18041-20000-24854	9460 N LAUREL CANYON BLVD	91331	7	198B161   111	2626014030	(Q)RD2-1-CUGU, [Q]C2-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	Apartment			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.24151	-118.41359	replace facp only.  reconnect to existing devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41022	18041-20000-24943	21550 W OXNARD ST STE 1100	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	01/24/2024 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 Energy only in existing space T.I. new lighting. Total area: 725 sq ft B#18016-10000-20866	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41023	17041-20004-10065	12035 W WILSHIRE BLVD	90025	11	126B145    25	4265016043	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Approved	01/15/2020 12:00:00 AM	ADDRESS	34.04541	-118.46622	Changes on approved set. Address delta 4 changes. Changes include adding emergency exit signs, installed exterior exit signs and light fixtures 3rd stairs, and show elevator equipment on single line diagram.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41024	17041-20000-09085	13229 N GLADSTONE AVE	91342	7	225B157   700	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Issued	07/06/2017 12:00:00 AM	ADDRESS	34.3112	-118.42915	Plan check for power only. New 400A service 'MSA' for thrift store. Refeed existing unit panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41025	16041-10000-03662	100 WORLD WAY SPACE 128	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Info Complete	02/02/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	T-24, PC FOR ENERGY ONLY. T.I. TO TERMINAL 1 OF LAX. EXISTING RETAIL STORE. TOTAL AREA 1311 SQ FT. SCOPE INCLUDES ADDING NEW LED RECESSED LIGHTS TO RETAIL STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41026	19041-20000-29028	11150 W OLYMPIC BLVD STE 600	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM			PC Info Complete	07/26/2019 12:00:00 AM	ADDRESS	34.03956	-118.43857	T24 PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL FOR STE 600. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1584 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41027	10041-10000-19085	8820 S SEPULVEDA BLVD Eastway	90045	11	096B165   989	4123001004	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	10/19/2010 12:00:00 AM	ADDRESS	33.95653	-118.39597	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41028	16041-10000-40974	1320 E 7TH ST #531	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	Title 24 plan check.  T.I. to existing two story office building.  Total area = 10,886 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41029	15041-10000-38379	4227 S MCLAUGHLIN AVE 1-14	90066	11	111B161   369	4233007007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.00093	-118.41878	Full PC for Newly constructed 14 unit apartment (4 stories). New Service of 1000A 3-Phase 4-wire delta connection. Total sq ft = 15561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41030	19041-40000-16138	7900 S LOYOLA BLVD EAST HALL	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	33.96604	-118.41693	PLAN CHECK FOR T24 ONLY FOR TI IN EAST HALL LOYOLA MARYMOUNT UNIVERSITY, ADD PANELS AND TRANSFORMER TO POWER LIGHTS AND POWER, NEW CONNECTED LOAD INCLUDING RELOCATED LOAD IS LESS THAN 400A. TOTAL AREA APPROX. 5,939 SQ.FTB# 19016-10000-11218	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41031	19041-10000-09172	767 E CALIFORNIA AVE	90291	11	108B145   428	4239018900	OS-1XL	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	33.99449	-118.46351	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41032	12041-20000-31151	19165 W MARILLA ST	91324	12	201B117   299	2762004007	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.24769	-118.55134	pv system 11.1 kw single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41033	14041-10000-13827	1249 W 65TH ST	90044	8	105B197  1376	6014002019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	33.98071	-118.29757	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41034	15041-10006-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	Bulletin # 18 revisions :  UPDATED SPOT LIGHTING FOR LEV 8 FOOD HALL;UPDATED CONDUIT PENETRATIONS FOR LEV 7 BOH  AND LEV 8 ROOF/TERRACE AND RESTAURANT SHELL AND LEV 8 ELECTRICAL ROOMS 8A-2&3; UPDATED LIGHTING FIXTURE SCHEDULE.ALL CHANGES ARE CLOUDED AND IDENTIFIED.((((((((((PC FOR POWER AND ENERGY. NEW DISTRIBUTION EQUIPMENT FOR FUTURE TENANTS. MALL IS GUTTING AND RENOVATING 8TH FLOOR FOOD HALL. ASSOCIATED HOUSE LOADS AND EQUIPMENT INSTALLED AT THIS TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41035	14041-10000-22666	909 N AVALON BLVD	90744	15	033B205  1336	7423004013	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	33.78153	-118.26274	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. RETAIL STORE. UPGRADE OF SERVICE. 2008 ENERGY COMPLIANCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41036	14041-20000-05139	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	Install new subpanels and transformer.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41037	14041-10000-12284	14006 W RIVERSIDE DR SUITE 228	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	TI remodel of existing retail space.  title 24 Yellow Box store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41038	18041-10000-11087	1011 S SERRANO AVE	90006	10	129B193   356	5080014012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Public Safety Only			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.0522	-118.3065	New fire warning system for 5-stories 104 units apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41039	17041-20001-34509	7749 N QUIMBY AVE	91304	12	189B097   974	2014032021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.21156	-118.63076	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.7.6kW ungrounded pv system. (30) 325W pv modules. (2) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41040	15041-20001-27842	23211 W INGOMAR ST	91304	12	189B093   587	2020022025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.21204	-118.63267	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (33) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41041	19041-20000-35316	1147 N BROAD AVE	90744	15	033B205   636	7423007017	[Q]RD3-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	33.78616	-118.26143	Plan check for power and energy. Project site is an existing apartment building. Project scope is replacement of electrical distribution equipment and service upgrade to 600A. Total lighting area = 1,951 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41042	16041-10000-45468	3052 1/2 S WELLINGTON ROAD	90016	10	120B185   754	5050029054	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.02616	-118.33826	PV2 3KW roofmounted system with 7 module interconnecting through a load center.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41043	17041-20002-31015	13919 W FOOTHILL BLVD	91342	7	225B153   325	2509002041	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.31242	-118.43638	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. ADDING OF MCC LOAD TO LOAD CALC PAGE, CHANGE TO VOLTAGE DROP, AND CHANGE TO MCC PANEL SCHEDULE.PERMIT FEE PAID UNDER E#17041-20001-31015	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41044	16041-20001-45451	258 S SERRANO AVE	90004	10	135B193   136	5517013027	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.06949	-118.30651	PV2.  Install 19.7 kW AC roof mounted grid tied PV system.  (70) modules with (2) 6kW and (1) 7kW rated central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41045	10041-20000-25027	10960 W WILSHIRE BLVD 21st Floor	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	04/22/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	T.I. to partial of an existing high rise building of 21st floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41046	19041-20000-36748	5727 N CANOGA AVE BLDG 12	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	05/14/2021 12:00:00 AM	ADDRESS	34.17529	-118.5978	PV2 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING APARTMENT BUILDING #12. SYSTEM SIZE IS 20.52 KW DC/18.68 KW CEC AC. SCOPE OF WORK CONSISTS OF (57) PV MODULES, A 100A PANEL, AND (3) 5 KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41047	17041-20000-00661	23655 W SANDALWOOD ST	91307	12	186B093   372	2027015024	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.20484	-118.6413	PV1.  Install 7.6 kW roof mounted grid tied PV system.  Central inverter standard plan.  In accordance with the requirements of 2014 NEC 690.12, array conductors extending more than 10' from the array will be disconnected from the array using a qualified rapid shutdown device - cutsheet attached to approved plans.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41048	19041-20000-34215	7850 N RUFFNER AVE	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.2142	-118.49665	Installation of new 2000A 480Y/277V distribution and transformers for cam-lock supplied equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41049	14041-10001-04677	610 N VAN NESS AVE	90004	4	141B189   605	5522005001	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/01/2014 12:00:00 AM	ADDRESS	34.08196	-118.31559	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(10) MODULES:  TRINA SOLAR TSM-250PA05.18}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41050	17041-20000-08744	500 S MATEO ST	90013	14	127-5A217  67	5163018005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.04146	-118.23294	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from warehouse to (4) new tenant spaces. Tota lighting area = 29,309 sq. ft.Note: Building application has been generated under 15014-10000/10001-01371. Tenant improvement for (1) of the tenant spaces can be found under 17041-20000-08741	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41051	19041-10000-16202	2731 W BEVERLY BLVD	90057	13	138A203   455	5156020018	C2-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Issued	10/30/2019 12:00:00 AM	ADDRESS	34.07044	-118.27861	Power plan check for an 800-Amp service upgrade with (6) new subpanels located in a hotel building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41052	16041-10000-07250	1828 E CESAR E CHAVEZ AVE	90033	14	130-5A221 325	5174008022	C2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.05014	-118.21571	Change of use from medical office to primary care clinic OSHPD 3 on floors 4, 5, and 6; TI of 19400 s.f of interior construction on floors 1, 4, 5, and 6; new roof structure for equipment enclosure; restriping  on floor 1 and one new standard stall on parking level 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41053	18041-20000-26137	1606 N LAUREL AVE	90046	4	147B177   535	5551016***	R3-1XL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.10031	-118.36414	Plan check for a PV2 roof-mounted PV system. System size is 38.64 kWdc/34.61 kWac-CEC and consists of (3) 10 kWac rated inverters, (2) load centers, and (112) modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41054	14041-20001-32968	3550 S TROUSDALE PKWY	90089	9	118-5A201   9	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.02094	-118.28463	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 3. CHANGE IN EMERGENCY LIGHTING LOCATION AND CHANGE IN EGREE FOOTCANDLE CALCULATIONS. NO CHANGE IN ENERGY DENSITY. PC FOR NEW EGREES CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41055	14041-10000-18640	20819 S NORMANDIE AVE	90501	15	054B197   106	7351022004	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	33.84131	-118.29972	PV1 4.59KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(18)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41056	12041-10000-17025	2761 S CLUB DR PV1	90064	5	126B165   559	4308003011	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.04153	-118.4049	Plan check for new 5.88KW roof mounted photovoltaic system using SolarEdge transformerless inverter and DC-DC power box. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41057	09041-10001-13510	619 S OCEAN FRONT WALK	90291	11	109-5A143 575	4286028019	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Public Safety Only			08/24/2010 12:00:00 AM			PC Approved	08/24/2010 12:00:00 AM	ADDRESS	33.99203	-118.47804	INSTALLATION OF NEW FIRE ALARM DEVICES TO EXISTING SYSTEM TO ACCOMODATE TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41058	15041-10000-05412	10880 W WILSHIRE BLVD 19TH FLOOR	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.05885	-118.44283	PC FOR T24. HIGH RISE BUILDING. TENANT IMPROVEMENT AT 19TH FLOOR OF ( E ) OFFICE BUILDING .B# 15016-10000-03504.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41059	11041-10002-18122	8231 W 3RD ST	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM			PC Approved	10/06/2011 12:00:00 AM	ADDRESS	34.07272	-118.36914	SUPPL. PLAN CHECK FOR CHANGES TO APPROVED PLANES.  First Time Tenants, Tenant Improvement on the first floor in the Mercedes-Benz Driving Academy. Plan check for Power & Energy.    <Permit was issued under 11041-90000-18122.  Core & Shell: 08041-10000-02697>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41060	17041-10000-05183	1507 N ECHO PARK AVE	90026	13	141A209   310	5419015004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.08016	-118.2554	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO TWO DIFFERENT RESTAURANT AND OFFICE SPACE. SCOPE INCLUDES A NEW 120/208 3 PHASE 4 WIRE SERVICE DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 7944 SQ. FT. B#15014-10000-05717	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41061	13041-20000-15074	4140 S GLENCOE AVE 1-69	90292	11	108B153  1141	4230006006	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			06/10/2013 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	33.98897	-118.4417	NEW CONSTRUCTION OF 69 UNIT APARTMENT COMPLEX. FIRE ALARM VARIANCE HAS BEEN FILED. PLAN CHECK FOR POWER AND ENERGY. NONHAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41062	14041-20000-13379	2768 W FYLER PL	90065	14	159A219    69	5684019020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.13152	-118.22676	7.5KW PV1 roof-mounted system with (2) Solaredge transformerless inverter model #  SE3800A-US, (30) Renesola modules model # JC250M-24/BB and a Solaredge Power Optimizer model # P300.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41063	18041-10000-36173	10250 W SANTA MONICA BLVD #1993	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Issued	10/29/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for a first time retail  interior T.I. Scope includes new lighting, equipment and receptacle with a total area of 698-SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41064	13041-20000-23186	12168 N YOUNGDALE AVE	91342	7	216B149   102	2611020002	RS-1	North Valley	Sylmar	Sylmar	YES	1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.29158	-118.45757	New 12.25kw Roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED.  Plan check and permit are for the PV system only, NOT for main service upgrade or derating of main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41065	15041-20000-44027	8436 W FORSYTHE ST	91040	7	207B189   300	2555038009	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.26601	-118.31714	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41066	15041-20000-40801	15030 W VENTURA BLVD STE. 12-15	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.15272	-118.46063	TI to an (E) beauty salon, added 3 new panels < 100A, adding new light fixtures. PC for Energy only, total area 2,579 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41067	14041-20000-34086	13806 W SUNBURST ST	91331	6	198B153   821	2642025013	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	12/26/2014 12:00:00 AM	ADDRESS	34.23725	-118.43401	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (19) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41068	11041-10000-03339	5670 W WILSHIRE BLVD 19TH FL	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	ADDRESS	34.06222	-118.35208	ALTERATIONS IN PRIVATE OFFICES AND OPEN OFFICEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41069	15041-20001-32309	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM			PC Info Complete	06/07/2016 12:00:00 AM	ADDRESS	34.30584	-118.47951	[[05-20-16 CHANGES OF AN APPROVED SET OF PLANS. CHANGES INCLUDE ADDITIONAL 3 PANELS ( PFD,  EL and EK) AND CIRCUITS; OTHER CIRCUITS ARE BEING RELOCATED AND REVISED FOR PHASED CONTSTRUCTION.  ADDITION OF WARNING LIGHTING. UPDATE FAULT AND LOAD CALCULATION. ]]]{{{{{{{Plan check for power and energy for T.I. clen room renovation. Total area phase 2 of 3: 16,195 sqft. Newly connected load: more than 400A. Note: refer to Building permit # 15016-20000-20385}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41070	12041-10000-14588	175 S LA BREA AVE	90036	5	138B181  1200	5513019039	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	ADDRESS	34.07151	-118.34422	PLAN CHECK T24 ENERGY FOR TENANT IMPROVEMENT OF EXISTING RETAIL SPACE #G3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41071	19041-10000-39879	301 WORLD WAY F/A	90045	11	090B161    33	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	12/27/2021 12:00:00 AM	ADDRESS	33.94423	-118.40709	FIRE ALARM TI TO LAX PARKING GARAGE #3. SYSTEM INCLUDE EXISTING CONTROL PANEL AND INITIATION DEVICES WITH (9) NEW POWER SUPPLIES AND (153) NOTIFICATION DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41072	19041-10000-03491	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Issued	10/24/2019 12:00:00 AM	ADDRESS	34.02201	-118.28947	TI POWER PC FOR  USC  in the Michelson Center for Convergent Bioscience SCHOOL LABS . SCOPE INCLUDES RELOCATION OF EXISTING PANELBOARDS AND adding  NEW BRANCH CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41073	13041-10000-11591	8201 W BEVERLY BLVD 402	90048	5	138B173   380	5514008046	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			PC Info Complete	05/03/2013 12:00:00 AM	ADDRESS	34.07624	-118.36815	TITLE 24 AND EMERGENCY LIGHTING. SIX STORY LOW RISE TI FOR 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41074	11041-20000-00974	8530 N TOBIAS AVE	91402	6	192B149   115	2638039021	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	03/15/2011 12:00:00 AM		Issued	03/15/2011 12:00:00 AM	ADDRESS	34.22569	-118.45152	T.I. to Food-4-Less.  Install panels, general and emergency lightings.  Plan check for energy and power. Subject for Green Building Compliance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41075	18041-20000-39957	926 S GRETNA GREEN WAY	90049	11	129B145   837	4264024022	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.04717	-118.47114	Plan check for PV roof mounted system, system size: 8.989 KW AC CEC, 10.08kW with 28 AC Modules connected to 400A Panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41076	18041-10000-37821	6600 N TOPANGA CANYON BLVD #2076	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI IN AN EXISTING RETAIL SPACE. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-32092	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41077	16041-20000-32525	7052 N MATILIJA AVE	91405	2	183B153   391	2216029007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.19913	-118.43331	Plan check for a PV1 roof-mounted PV system. System size  is 5 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41078	19041-20000-45493	5254 N MELVIN AVE	91356	3	171B117   152	2164023022	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.16702	-118.55955	Plan check for PV roof mounted system, PV system size: 7.77KW DC with 21 PV Modules and 1 inverter(7.6KW) connected to existing 400A service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41079	17041-20000-20818	1810 W SLAUSON AVE E	90047	8	108B193  1518	6001001025	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	33.98802	-118.31001	Plan check for energy only. TI to restaurant (panda express). New lighting (incl. emergency) - 1,513sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41080	18041-10000-17320	4525 W WILSHIRE BLVD 2ND FLOOR	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	PLAN CHECK FOR FIRE ALARM TI ON THE SECOND FLOOR CORRIDOR.INSTALL 6 ADDITIONAL DEVICES TO AN EXISTING FIRE ALARM SYSTEM UNDER PERMIT # 17041-10000-21560	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41081	12041-20000-26540	152 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM			PC Approved	11/05/2012 12:00:00 AM	ADDRESS	34.07453	-118.32342	NO NEW SERVICE INSTALLED. USING ORIGINAL EQUIPMENT. plan check for energy and emergency lighting only. 1860 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41082	18041-20000-13551	19191 S VERMONT AVE STE 450	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT WORK ON APPROX. 3,860 SF OF THE TOTAL FLOOR AREA.BUILDING PERMIT # 18016-10000-08931	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41083	13041-10000-34553	1150 E 12TH ST	90021	14	123A213   233	5132016011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	ADDRESS	34.03048	-118.24625	T24 PART 6 ENERGY LIGHTING WORK FOR RETAIL SPACES 1,2,3 AND RESTROOMS. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING WORK IS APPROX. 7740 SQ FT (INDOOR 4500 SF, OUTDOOR 3240 SQ FT) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41084	13041-10001-28407	6333 W 3RD ST BLDG E-UNIT #K7	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Approved	11/20/2013 12:00:00 AM	ADDRESS	34.07157	-118.36014	TITLE 24 PART 6 ENERGY PLAN CHECK FOR A Remodel/Conversion into commercial kitchen (food prep for onsite restaurant).  SUPPLEMENTAL TO #13041-10000-28407 DUE TO LOST OF PLAN. A COMPLETE NEW PLAN CHECK WILL BE DONE UNDER THIS SUPPLMENTAL #.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41085	14041-20001-11622	226 S OCEANO DR	90049	11	132B141   366	4404033005	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.0588	-118.47263	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. MICROINVERTER M215. ADDING 20 MODULES TO EXISTING 10. SYSTEM SIZE: 9KW(20) LG 300 MODULES(20) M250 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41086	19041-20000-52862	3758 N COLDSTREAM TER	91356	3	162B117   333	2180018005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.138	-118.56223	PV1.  Install 10.34 kW AC CEC roof mounted PV system.  (36) modules with 10 kW rated inverter.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41087	15041-10001-42066	4619 N CARITINA DR	91356	3	168B117   516	2178020013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.15408	-118.5566	EXPEDITE FEESPV1 SFD TOTAL SYSTEM SIZE 14KW AC USING 2 CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41088	19041-10000-11372	2666 W OLYMPIC BLVD	90006	1	129B197   273	5076009005	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.0522	-118.28994	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41089	18041-30000-13082	2029 S CENTURY PARK EAST Concourse	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is the corridor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,050 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41090	19041-10000-50689	1 N IVERSON ROAD	91311	12	210B101   290	2723021083	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	03/17/2020 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.276	-118.60976	[EPLAN] TWO ESS (TESLA POWERWALL), 2 SUBPANELS ONE RATED FOR 200A AND ONE RATED FOR 300A WITH AN EXISTING MAIN SERVICE RATED FOR 600A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41091	14041-10000-09745	10414 W CROCKETT ST	91352	2	192B177   820	2407003005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.21999	-118.35893	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41092	18041-10000-38709	1541 W WILSHIRE BLVD #200	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	02/20/2019 12:00:00 AM		Issued	02/20/2019 12:00:00 AM	ADDRESS	34.05529	-118.26949	T.I. FOR CORE AND SHELL. INTERIOR - SECOND FLOOR. NEW DISABLED ACCESSIBLE RESTROOMS, ELEVATOR LOBBY, JANITOR CLOSET & STORAGE CLOSET. NEW PLUMBING FIXTURES. SPRAY FOR FIRE PROOFING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41093	17041-10000-46302	14240 S VERMONT AVE	90247	15	075B197   208	6119015018	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	33.90252	-118.29147	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41094	17041-30000-18201	801 S FIGUEROA ST 10th-Rest room	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only T.I. restroom 10th Floor. Total area: 640 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41095	14041-10001-27847	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	07/24/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	7/24/2015 PLAN CHECK FOR CHANGES TO SET OF PLANS DELTA 1 AND DELTA 2. RESHUFFLING OF LOADS AND RELOCATION OF PANELS. NO NEW LOADS HAVE BEEN ADDED. ((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX TERMINAL 1. CHANGING OF THE POWER DISTRIBUITION SYSTEM AND LIGHTING.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41096	19041-20000-01569	10325 N GLENOAKS BLVD	91331	7	204B165    65	2537018034	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	08/22/2022 12:00:00 AM	ADDRESS	34.25782	-118.39588	PV3.  Install 32.01 kW DC roof mounted grid tied PV system.  (97) modules with (3) 10 kW rated string inverters.Fee S50.68 due California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41097	19041-10000-22716	6955 N HAYVENHURST AVE	91406	6	183B137   296	2225002021	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.19722	-118.49258	REPLACE INDOOR & OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41098	17041-10000-12433	992-998 W 8TH ST	90017	14	129A207   123	5144022028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.04846	-118.26264	Plan check for power and Title 24.  Change of use from garage to 3 separate shell retail spaces.  New EV chargers, lights, receptacles, and HVAC.  Total connected load exceeds 400 amps.  Total area = 2,241 sq. ft.     Building permit #17016-10000-06201	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41099	19041-20001-51512	3143 N DONA SARITA PL	91604	2	159B173   624	2380021014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			PC Approved	12/27/2019 12:00:00 AM	ADDRESS	34.12868	-118.37819	Expedite per applicant requestPlan check for PV roof mounted system, PV system size: 16.38KW with 52 PV Modules and 2 inverters(7.6KW), Energy Storage system size: 54KWh with 4 Energy Storage Devices(Tesla Power Wall 2.0)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41100	15041-20000-07303	23517 W WINDOM ST	91304	12	186B093   259	2027036025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM			Plans on Hold	04/22/2015 12:00:00 AM	ADDRESS	34.20651	-118.64078	Installation of new roof mounted solar PV system.  Total system size = 12 kWac.  40 modules (6 strings total) connected to 2 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41101	19041-10000-42961	1213 N AMALFI DR	90272	11	129B133    96	4425007013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	06/18/2020 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.05187	-118.50615	$0 permit fees due per Assembly Bill 1414. NEW ROOF MOUNTED 14 KW, WITH (38) SOLAR MODULES (370W) AND TWO 11.4KW BATTERY SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41102	13041-20000-00067	6507 W HOLLYWOOD BLVD	90028	13	148-5A187 137	5547007011	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			01/02/2013 12:00:00 AM	03/18/2014 12:00:00 AM		Issued	03/18/2014 12:00:00 AM	ADDRESS	34.10176	-118.33132	((CHANGES MADE TO APPROVED PLANS. PLANS NOT PERMITTED YET. MOVED THE BATHROOMS AROUND, ADDED 3 EMERGENY LIGHTS, ADDED 2 EXHAUST FANS, AND VANITY LIGHTS OVER THE BATHROOM SINKS))Change of use from retail to restaurant.  Occupancy load is 104, place of assembly.  Full Plan Check required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41103	19041-20001-09559	8479 N MOORCROFT AVE	91304	12	192B101   251	2004019009	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.2243	-118.6123	Revisions to an approved set of plans.  Critical load backup panel feeder rating changed from 60A to 100A.  Schedule of backup loads altered.  Approval for clouded and initialed portions of SLD only. (((INSTALLATION OF A 5KW TESLA POWERWALL TO A EXISTING SFD WITH A EXISTING PV SYSTEM AND A 125A SUBPANEL.  175A MAIN BREAKER DERATE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41104	15041-20000-20543	20208 W BLYTHE ST	91306	3	189B113   667	2107020058	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.2146	-118.57309	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  SIngle inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41105	15041-20001-23458	6316 N TOPANGA CANYON BLVD B-1620	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	CHANGES TO AN APPROVED SET. ADDING NEW LOAD TO PANEL 'A' AND INCREASING THE SIZE OF A TRANFORMER. PERMIT FEES UNDER PCIS#15041-20000-23458Plan check for power and Title-24 (energy).  Total area = 1,676 sq. ft.  T.I. to commercial first time tenant.  New electrical distribution for nail salon.  Lighting, recepticles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41106	14041-10000-24106	755 W LACONIA BLVD	90044	15	081B197   253	6117018022	RD1.5-1XL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	33.91762	-118.28867	PV1 Standard plan, 8.925KW roof-mounted system including (2) PowerOne  PVI-3.6 and 3.0 OUTD inverters and  (17) Kyocera KD255GX modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41107	17041-20000-44230	521 E BOCCACCIO AVE	90291	11	108B149  1534	4237007008	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	07/06/2021 12:00:00 AM	ADDRESS	33.98877	-118.45821	New 2-story manufacturing building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41108	13041-20001-22944	7725 N DELCO AVE	91306	3	189B109  1013	2107014015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.21099	-118.57886	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5 KW USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. PC REQUIRED. TOTAL OF 24 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41109	13041-10000-28820	6352 N RIVERTON AVE	91606	2	180B177   279	2414009001	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Apartment			10/16/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.18637	-118.36578	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS UNGROUNDED. SYSTEM SIZE: 4.5 kW DC.(18) TRINA SOLAR # TSM-250(1) SOLAREDGE # SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41110	16041-10000-04898	10111 W LA TUNA CANYON ROAD	91352	7	195B181    38	2544020007	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.23511	-118.35145	PV1, rooftop solar installtion 4.5kW system(18) SW280 MOno(18) M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41111	14041-20000-13462	18207 W CHARLTON LANE	91326	12	213B125   109	2870018015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.28317	-118.53049	7.5KW PV1 roof-mounted system with (30) Polycrystalline Solar modules model # SMX250, and (2) Sunny Boy SMA SB3000TL-US - 22 and SB3800TL-US inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41112	12041-10000-14773	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	34.10686	-118.33085	Plan check T24 Energy/Emergency lighting for Office Suite #107 TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41113	16041-10000-05392	404 S FIGUEROA ST	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.05326	-118.25596	PC for energy only to Bonaventure hotel (3rd floor only). Teneant improvement to conference room and waiting area. Total sq ft = 1400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41114	16041-10000-03996	16652 W VENTURA BLVD	91436	5	168B137   345	2289020022	C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.15799	-118.49645	TENANT IMPROVEMENT FOR (E) RETAIL BUILDING ACE HARDWARE. INSTALL NEW LIGHTS AND RECEPTACLES. PC FOR T-24 ONLY. TOTAL AREA 7,383 SQ.FT. T-24 FOR SIGN WILL BE FILED AT LATER TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41115	18041-10000-08039	21260 W DEERING CT	91304	3	189B105   253	2109001027	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.21472	-118.59647	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 24300 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41116	15041-20000-08772	17061 W LASSEN ST	91325	12	201B133   128	2694008035	(T)RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.25042	-118.50439	PV1. Standard plan. Install roof mounted PV system size 6 kW in SFD. Interconnected with main service panel.(15) X21-345 Panels(1) SB 6000 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41117	11041-10000-08248	1200 S WALL ST	90015	14	124-5A209 213	5145026035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	05/26/2011 12:00:00 AM	ADDRESS	34.03477	-118.25537	T.1 FOR 2ND AND 3RD FLOOR.  SAME TENANT FOR EXISTING RETAIL SPACE.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41118	18041-10000-18993	124 S CROFT AVE 1-4	90048	5	138B173   687	5511014007	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	01/18/2023 12:00:00 AM	ADDRESS	34.07387	-118.37406	NEW FIRE WARNING SYSTEM FOR 5-STORIES APARTMENT BUILDING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41119	18041-20001-43997	11862 N KILLIMORE AVE	91326	12	213B121    31	2872013001	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.28443	-118.53933	11-27-2018 Changes to an approved set of plans, Changes include update AC Modules model # to SUNPOWER:SPR-X21-360-D-AC MODULES. All changes has been clouded. Plan check only.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41120	11041-10000-15201	8500 W BEVERLY BLVD # 622	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI TO AN (E) RETAIL SPACE IN A COVERED MALL; PLAN CHK IS FOR TITLE 24; PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41121	15041-10000-20069	23634 W CALVERT ST	91367	3	177B093   494	2035006004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM			Reviewed by Supervisor	08/11/2015 12:00:00 AM	ADDRESS	34.18135	-118.6421	PV1.  Install 11.772 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(36)MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTERS: ABB PVI-6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41122	19041-10000-29996	10316 N SEPULVEDA BLVD	91345	7	204B145   250	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Closed	08/17/2020 12:00:00 AM	ADDRESS	34.25783	-118.46706	Addition to an exisitng fire alarm system, scope of work includes a new fire alarm panel and 53 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41123	16041-20000-30835	837 N SPRING ST	90012	1	135A215   307	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	11/08/2016 12:00:00 AM	PIN	34.06307644	-118.23671541	SERVICE UPGRADE (2) 1600 AMP SERVICES.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41124	14041-10000-26713	802 E 61ST ST	90001	9	105B205   595	6007009013	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	33.9843	-118.26115	Power plan check for a service upgrade to 600 Amp, and (2) panels connected to existing load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41125	19041-10000-46822	4759 W HOLLYWOOD BLVD	90027	4	147B197   202	5589030032	C2-1D	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	04/05/2022 12:00:00 AM	ADDRESS	34.10193	-118.29374	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41126	13041-10001-35856	540 S COMMONWEALTH AVE	90020	13	135A201   133	5077005027	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	ADDRESS	34.06395	-118.28551	3/14/16: Changes to approved set noted on Delta-A: Re-arranged electrical room to accomodate Outdoor Underground Methane Pull section per LADWP standard and Omitted Sump pump.<<PLAN CHECK FOR POWER AND ENERGY TO A NEW CONSTRUCTION,  FIRST CONGREGATION CHURCH. METHANE ZONE PER ZIMAS. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 75,388 SQ FT. NEW 400A, 480Y/277V, 3PH, 4W SWITCHBOARD 'MSB'. LIGHTING MOSTLY CONSIST OF 277V LIGHTING CKTS.plan check extensions have been filed.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41127	15041-10000-39386	511 W MAC ARTHUR AVE	90731	15	021B197   734	7448021013	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	33.75087	-118.28834	PV1INSTALL ROOF MOUNTED PV SYSTEM WITH  (1) 3KWABB-INVERTER AND (9) KYOCERA MODULES INTERCONNECTED WITH MSP.STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41128	15041-10000-09134	656 S AVENUE 61	90042	14	150A233   129	5312026039	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.10554	-118.18086	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW, and (17) Kyocera KU2606X{A modules. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41129	17041-20001-30991	5531 W WASHINGTON BLVD	90016	10	126B177  1593	5064017001	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.03731	-118.36423	12/08/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan. No change in lighting fixture counts.*****Previous Work Description*****PC FOR OFFICE TI (E) TITLE-24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA 1967 SQ.FT. PERMIT IS REFER TO APPLICATION # 16041-30000-32232	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41130	16041-10001-17366	2159 E SACRAMENTO ST	90021	14	123A217   222	5166005008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Approved	06/09/2016 12:00:00 AM	ADDRESS	34.0307	-118.22801	06/09/16Changes to an approved set of plans. All changes are made under delta A. Changes include adding the existing single line diagram and existing panels to the plans. Changes to reflect what is on the field. NOTE: PERMIT IS PULLED UNDER PCIS#15041-20000-24284Plan check Title 24 only for T.I.  in existing office space. Total indoor lighting area: 10,617 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41131	14041-20002-16548	12746 W JEFFERSON BLVD Unit 3140	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	"Changes to approved set.  Relocation of distribution board ""DP"".  New conduit routes from 300 kVA transformer.  All changes couded with delta 3.*****Previous Work Description*****Full plan check for power and lighting.  Change of use from retail to restaurant."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41132	17041-10001-18726	834 1/2 W 41ST ST	90037	9	114B197   478	5019003025	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Apartment			06/05/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.00906	-118.2885	Expedite fees only.       Installation of new roof mounted solar PV system on existing 3 unit apartment building.  Total system size = 3 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41133	13041-20000-01289	11500 W OLYMPIC BLVD # 600	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.03624	-118.44415	Installing lights, receptacles and panel boards.  TENANT IMPROVEMENT IN EXISTING  FOUR SUITES, SAME TENANT, 6TH FLOOR PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41134	13041-20001-26792	18741 W FRANKFORT ST	91324	12	192B121   692	2785021008	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.22145	-118.5418	EXPEDITE FEES ONLY.<<<New 10.4kw rooftop PV system for an existing single family dwelling.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41135	14041-10000-28484	1034 S CATALINA ST	90006	1	129B197   357	5078012017	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05171	-118.29462	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.PV2 xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(5) inverters: {DELTA SOLIVIA 5.2TL}]. [(104)modules: {LDK SOLAR , LDK-280P-24}]. Changes on plans include removal of ground rod and PV wire PVX1019.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41136	13041-20003-16989	8375 N LAUREL CANYON BLVD	91352	6	192B165   307	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.22391	-118.39926	Modifications to approved set.  (2) additional meters and tenant panel upgrades for future loads.   (((UPGRADING (2) 2000A MAIN SWITCH BOARDS AND ALL THE FEEDERS FOR CANYON PLAZA SHOPPING CENTER. NO LOADS ARE BEING ADDED TO THE PANELS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41137	15041-10003-35073	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	CHANGE TO APPROVED SET. CHANGES NOTED DELTA 36 ON PLANS. INCLUDES NEW CIRCUITS AND REVISED CIRCUIT DESCRIPTIONS. NEW HOME RUNS HAVE BEEN SHOWN ON FLOOR PLANS.Power only!!	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41138	18041-20000-32948	1900 S AVENUE OF THE STARS STE 2500	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for Title 24 only in existing space high-rise building 25th Floor office T.I. Total area; 3500 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41139	14041-20000-13615	16403 W VENTURA BLVD SPACE 4C	91436	5	168B137   347	2260009043	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.15747	-118.49025	TI for one story bakery tenant space in a commercial shopping center.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41140	19041-10000-30213	3400 W OLYMPIC BLVD 2nd floor	90019	10	129B193   344	5081031025	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.05245	-118.31249	PC FOR T24 ONLY SCOPE OF WORK IS CHANGE OF USE FROM RETAIL TO OFFICE ON THE ENTIRE 2ND FLOOR IN A LOW RISE BULDING. SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 9750 SQFT.BUILDING PERMIT: 19016-10000-08504	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41141	15041-20001-16278	936 S OLIVE ST UNIT 357	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #5 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41142	19041-10000-08492	11111 W SANTA MONICA BLVD 19TH FL.	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.04771	-118.44481	Energy plan check for an office T.I located on the 19th floor of  commercial building. Scope includes new lighting and equipment with a total area of 883-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41143	15041-20000-23696	15760 W STRATHERN ST Bldg. 1	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.21559	-118.47701	Plan check for power and energy.  Total area = 21,532 sq. ft. (indoor) + 6,632 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41144	17041-20001-00689	16934 W PLUMMER ST	91343	12	198B133    79	2687001029	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.24279	-118.50135	expedite per applicant.pv1install roof mounted pv system sized 11.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41145	15041-10000-04274	9835 N INDEPENDENCE AVE	91311	12	201B105   107	2746003016	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.24907	-118.59093	Plan check for Title 24 only. Project is an existing building. Total lighting area = 1,888 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41146	14041-20000-21390	13262 W MERCER ST	91331	7	210B157   880	2535016001	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.26893	-118.42169	PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 3.655kW(17) EnPhase M215-IG microinverters(17) Hyundai HiS-M250G pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41147	12041-10000-11912	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	33.98645	-118.44148	T.I. to an existing office space, in an existing commercial building.  Change to lighting and receptacles.  Existing circuits, load is less than 400A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency.  Permit fees are under Inspection for 44 lights, 5 switches, 1 exit sign, 24 outlets and misc permit for low-voltage items.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41148	17041-20000-37484	14505 W SUNSET BLVD	90272	11	129B129   950	4423024016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.04555	-118.51533	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (29) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41149	13041-10001-31469	1236 W LEIGHTON AVE	90037	8	117B197  1164	5037003003	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.01307	-118.29858	Express  RSES plan check per applicant request.(((PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US.  16 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41150	18041-20000-34136	4530 N HASKELL AVE	91436	5	168B141   828	2283002031	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.15336	-118.47393	pv1install roof mounted pv system sized 10KW AC / AC CEC 11.06KW interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41151	19041-10000-45567	738 N CAHUENGA BLVD	90038	13	141B185   396	5533032029	CM-1VL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.08455	-118.3286	Energy plan check only, area of scope 1285SFBuilding permit PERMIT # 18016-10000-30475	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41152	13041-10001-24420	10055 N BEACHY AVE	91331	6	204B153   712	2647021004	RA-1	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.25385	-118.44454	][][][]EXPEDITE PER APPLICANT REQUEST][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 18.18KW DC IN A TWO-STORY SINGLE FAMILY DWELLING. 2 NEGATIVELY-GROUNDED INVERTERS.(74) MODULES: TRINA SOLAR #TSM-245PC05/PA05.18(2) INVERTERS: FRONIUS #IG PLUS V 7.5, INVERTERS: FRONIUS #IG PLUS V 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41153	18041-20000-44891	1645 S BEVERLY GLEN BLVD	90024	5	132B157   490	4327005019	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			11/26/2018 12:00:00 AM			PC Info Complete	09/17/2019 12:00:00 AM	ADDRESS	34.05855	-118.42517	Plan check for power and energy. Project site is a 4-story, 34-unit apartment building. Work includes a 2,000 Amp serice and a total lighting area of 27,059 sq. ft.Note: Building application has been generated under 18010-10000-05494	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41154	19041-10000-09837	2027 E 7TH ST	90021	14	124-5A217 222	5164020016	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM			Reviewed by Supervisor	03/27/2019 12:00:00 AM	ADDRESS	34.03473	-118.23139	FIRT TIME TENANT TO RESTAURANT WITH NEW PATIO COVER ADDITION. PLAN CHECK FOR POWER & ENERGY.  BULDING PERMIT: 19016-10000-04139	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41155	11041-10000-01010	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005019	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.15303	-118.39667	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41156	14041-20000-24841	7010 S HOOVER ST Unit #7	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #7. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41157	19041-10000-40115	5340 S ALLA ROAD	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	33.9773	-118.42567	TENANT IMPROVEMENT FOR 2 LEVELS  EXISTING OFFICE BUILDING.  SCOPE INCLUDING  NEW LIGHTS & LOADS. AFFECTED AREA: 21,822 SQ FT. BUILDING PERMIT: 19016-10000-25638	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41158	19041-20000-16157	1500 S GRANVILLE AVE	90025	11	126B149   386	4262006032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/01/2020 12:00:00 AM	PIN	34.04297561	-118.45708387	Plan check for power and energy.  Work includes a 4,000-amp service and a total lighting area of 151,897 sq. ft.Note: Building permit has been issued under 16010-10000-04258	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41159	12041-10001-02512	427 S BOYLE AVE	90033	14	127-5A221 224	5174002016	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Apartment			01/08/2013 12:00:00 AM			Reviewed by Supervisor	01/15/2013 12:00:00 AM	ADDRESS	34.04213	-118.21983	((((((((((((  REVISION TO APPROVED PLANS CHANGES CONSIST OF: DIFFERENT MODULES, INVERTORS, NEW SUBPANEL AND TRANSFORMER)))))))))))))     Plan check for 127KW roof mounted and grounded mounted photovoltaic system for an existing apartment buildind. New 400A service, switchboard, and electric vehicle charger. Site located in Methane Buffer Zone. Existing equipment shall be suitable for new fault current.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
41160	14041-20001-04582	824 E 17TH ST	90021	14	121-5A211 190	5131001047	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM			PC Approved	01/11/2016 12:00:00 AM	ADDRESS	34.02736	-118.25302	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE EXISTING PANEL COONNECTED TO NEW MAIN SWITCHBOARD. RECHECKING FOR NEW SHORT CIRCUIT AND (E) AIC VALUESALL CHANGES CLOUDED DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41161	13041-20002-06699	10635 N WOODMAN AVE	91345	7	207B149   430	2648004045	(T)RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.26343	-118.45534	Revisions to approved set.  Revised lighting schedule and lighting configuration, new panels, loads, and distribution equipment.  Approval for clouded revised portions only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41162	15041-10000-07579	5519 W HOLLYWOOD BLVD	90028	13	148-5A193 132	5544005002	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.10188	-118.31005	SERVICE UPGRADE 800 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41163	19041-10000-01630	10512 W MAGNOLIA BLVD	91601	4	171B177   702	2419020004	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Issued	01/22/2019 12:00:00 AM	ADDRESS	34.16476	-118.3598	PV PLAN CHECK FOR 6.930KW(DC) AND 6KW(AC) COMMERCIAL. 22 MODULES (Q.CELLS Q.PEAK DUE-G5 315). 22 OPTIMIZERS SOLARE EDGE P320.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41164	13041-10000-25434	1875 S CENTURY PARK EAST #200	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.06115	-118.41457	PC FOR ENERGY ONLY. TI TO (E) OFFICE #200. HIRISE EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41165	11041-10000-03076	763 N SEWARD ST	90038	4	141B185   280	5533037001	CM-1VL	Central	Hollywood	Greater Wilshire		1918.20, 1919.00	Electrical	Electrical	Commercial			02/16/2011 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.08512	-118.33325	EXISTING RETAIL AREA, SINGLE STORY.   T.I. WITH T-24 ONLY.  UPGRADE PANEL AND LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41166	13041-10000-34376	7554 W MELROSE AVE	90036	5	141B177   653	5526016001	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Expired	01/05/2016 12:00:00 AM	PIN	34.08340124	-118.3545881	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 1440 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41167	14041-10000-19408	2904 W CASITAS AVE	90039	1	151-5A211 360	5442001001	[Q]MR1-1-CDO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.11111	-118.24667	Installation of roof mounted PV solar power system.  Total system size = 40 kWac. ZERO FEES DUE TO 2012 SENATE BILL NO.1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41168	15041-20000-34336	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.20615	-118.41279	PLANCHECK FOR POWER ONLY. INSTALLATION OF NEW BUSWAY AND EQUIPMENT FOR LEAPX .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41169	10041-10001-21899	1154 N HIGHLAND AVE	90038	4	144B185   509	5532020002	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			PC Approved	05/02/2011 12:00:00 AM	ADDRESS	34.09225	-118.3384	TITLE 24 PLAN CHECK ONLY.  NO PERMIT TO BE ISSUED ON THIS APPLICATION NUMBER.  SEE EXISTING PERMIT ON APPLICATION  # 10041-30000-21899.  MODIIFICATION TO LIGHTING.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41170	15041-10001-10711	6130 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM			Corrections Issued	01/27/2016 12:00:00 AM	ADDRESS	34.09779	-118.32344	1/27/2016CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES ON DELTA 4. CHANGES INCLUDE THE ADDITION OF OUTLETS FOR CASE LIGHTING DISPLAY. (((T24 FOR EXISTING RITE AID DRUG STORE. CHANGING LIGHT FIXTURES IN 12500 SQRFT RETAIL AREA)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41171	19041-10000-28328	757 S ALAMEDA ST #128, 132-& 138	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Issued	07/31/2019 12:00:00 AM	ADDRESS	34.0318	-118.23916	TI IN AN EXISTING COMMERCIAL AREA IN SUITE# 128, 132, 138.INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. TOTAL AREA: 4,791 SQR FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41172	13041-20000-27471	5915 N JELLICO AVE	91316	5	177B129   804	2254002029	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.17787	-118.51757	ADDITION TO EXISTING PV SYSTEM. SCOPE OF WORK IS NEW 3KW AC INVERTER. 8 NEW PANELS. AND NEW PV SUBPANEL. 4.2 KW PV SYSTEM EXISTING. NOT PART OF THIS PLAN CHECK.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41173	17041-20000-04995	17619 W COVELLO ST	91406	6	186B129   331	2202024014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.20765	-118.51709	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41174	18041-30000-37473	12800 W WENTWORTH ST	91331	6	198B161   395	2629027***	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	34.23659	-118.41161	NEW FIRE ALARM SYSTEM IN A COMMERCIAL SPACE USED FOR HYDROPONIC AGRCUTURAL ENTERPRISE; (1) FACP, (80) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41175	15041-20000-39776	5800 W SUNSET BLVD PHASE 2	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			Verifications in Progress	01/27/2016 12:00:00 AM	ADDRESS	34.09728	-118.31693	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENTS FOR TV STUDIOS AND ASSOCIATED SUPPORT SPACES..  PHASE 5 of 5 PHASE PROJECT FOR STAGE 6 AND BUILDINGS 16. STAGE 6- [[[ FEES BASED ON APPLICANT- PLANCHECKER TO REVERIFIY]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41176	16041-20001-04930	11511 W TENNESSEE AVE	90064	11	123B153   233	4260016005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.03484	-118.44331	03/02/2016 Plan check for Title 24 only. Project site is an existing commercial building. Plan check scope is lighting work being done within a hazardous location. Total lighting area = 12,370 sq. ft.*****Previous Work Description*****PLANCHECK FOR POWER  FOR CAR SERVICE EQUIPMENT AND GARAGE. HAZARDOUS LOCATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41177	16041-30000-16710	2430 N BOWMONT DR	90210	4	153B165    95	4388012061	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.11724	-118.39763	Plan check for a new single-family dwelling. Work includes a new 600-amp 120/240V service and associated loads. Note: Building permit has been pulled under 15010-30000-01244	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41178	12041-10000-17391	6344 W FOUNTAIN AVE	90038	13	144B185   166	5533005057	C2-1-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Info Complete	11/08/2012 12:00:00 AM				RECONNECT EXISTING LOAD BETWEEN TWO SERVICES.  RECONNCT THE PANELS A, B & C AND TWO 75KVA TRANSFORMERS FROM 800 AMP TO 1600 AMP SERVICE AND RECONNECT THE AC UNIT FROM 800AMP TO 1600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41179	19041-20000-22474	16326 W SAN JOSE ST	91344	12	207B137   825	2679010011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.26092	-118.48803	Plan check for a PV1 roof-mounted PV system. System size is 7.36 kWdc/7.6 kWac and consists of (1) inverter, (23) modules, (1) load center, (1) battery back-up unit, and (1) auto-transformer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41180	10041-20000-08710	155 W WASHINGTON BLVD	90015	9	123A207    74	5126028010	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	11/07/2012 12:00:00 AM	ADDRESS	34.03191	-118.26615	REPLACE FIRE ALARM SYSTEM WITH NEW FIRE ALARM ON HIGH RISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41181	13041-10007-26817	5900 W CENTER DR	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			06/15/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	33.97559	-118.38853	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 10.1 - CHANGES INCLUDE DOG SPA AREA INSTEAD OF ELECTRIC ROOM. NEW WIRING AND TITLE T24 PROVIDED. NEW ENGINEER PROVIDED FOR DELTA 10.1 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41182	14041-10000-16483	13024 W WARREN AVE	90066	11	114B149   357	4244005011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.00993	-118.45165	PV1, INSTALL 4.335 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. ON TRANSFORMERLESS INVETER, WITH OPTIMIZERS.(17) MODULES: TRINA SOLAR # TSM-255PA05.18(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41183	14041-20000-29798	3454 E 14TH ST	90023	14	118-5A225 396	5190037004	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Closed	09/01/2015 12:00:00 AM	ADDRESS	34.01718	-118.20443	Service upgrade to 600A for existing building.    Install empty panels for unoccupied tenant space.  No branch circuits and lighting work.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41184	16041-20000-00088	10228 N BARTEE AVE	91331	6	204B153   404	2617003064	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.25644	-118.43819	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. Standard plan.(20) Solarworld SW 285 Modules(1) SMA SB6000 TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41185	14041-20000-15260	22707 W BERDON ST	91367	3	174B097   650	2040012010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.17115	-118.62153	New roof mounted PV system with optimizers.  Total PV system size 7.28KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41186	15041-20000-43613	5243 N BABCOCK AVE	91607	2	171B161   377	2346013044	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	01/05/2016 12:00:00 AM	ADDRESS	34.16611	-118.40652	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.275KWdc/3.75KWac(15)MODULES-SOLARWORLD SW285 MONO(15)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41187	16041-10000-12531	1420 W 36TH ST	90731	15	009B193   905	7470022009	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Expired	05/11/2018 12:00:00 AM	ADDRESS	33.71697	-118.30833	PV1, INSTALL 4.59 KW DC / 3.60 KW AC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(18) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI -3.6-OUTD-S-US Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41188	14041-10000-16331	6255 W SUNSET BLVD #1480	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Permit to be pulled at EPC counter only. Plan check for energy only. T.i to (E) office space on 14th floor of 22 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41189	16041-20001-44200	5170 N SEPULVEDA BLVD 140-170	91403	4	171A145    43	2263002041	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.16461	-118.46592	Revisions to approved set.  Changes/additions related to HVAC equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41190	11041-10001-26949	15225 W VANOWEN ST	91405	6	183B145   787	2220020024	C1-1L, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM			PC Info Complete	07/19/2012 12:00:00 AM	ADDRESS	34.19406	-118.46455	New 4th story office building over basement garage.  New service, panels, and standby generator.  Plan check for core and shell only. (Applicant to verify if this will be a Medical Building).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41191	13041-10000-00291	10201 W PICO BLVD build 101	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			01/04/2013 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	PC FOR T24 Building 101. Square footage: 6683. All the lighting is emergency lighting. Permit for new lighting and receptacle outlets for office modular funitures. All branch circuits are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41192	17041-20005-14437	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	"12/1/2017changes to an approved set of plans.  changes noted delta 9.  changes to reflect field conditions.this is plan check only.[[10/31/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 8 CHANGES CLOUDED. RELOCATING AC LOADS TOPANEL HA. PROVIDNG LOAD CALCULATION FOR DISTRIBUTION BOARD DBA]]]]10/23/2017changes to an approved set of plans.  changes noted delta 7.  changes include relocating existing equipment from distribution board ""DBA"" to house section ""MMH"".  no change in connected load.  this is plan check only.  10.18.2017 - Plan check for modifications to approved set. Update SLD to show actual connected load for conveyor system and panel MCP (400A). Update inverter to 10kW single phase 277V. Relocate equipment - panels 1LA, HA, HL, transformer T-LA, and inverter. Changes clouded delta 6.=======08/04/2017 Changes to an approved set of plans. All changes have been clouded and marked as Deltas 1, 2, and 5. Loads have been recircuited/relocated and there have been slight lighting changes.*****Previous Work Description*****Plan check for Power and energy wearhouse and office space T.I. new panels, lighting and receptacle. Total newly connected load exceed 400A feed from Existing 800A switch gear. Total area indoor lighting: 249,391 sq ft. B#17041-30000-04976"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41193	14041-10000-28254	939 S BROADWAY	90015	14	127-5A209 285	5139003006	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.04157	-118.25708	fire alarm variancePLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO LIVE WORK. 12 STORY, HIGH RISE. 151 UNITS. Building P# 13016-10000-15414 .CHANGE OF USE OF 12-STORY LIGHT-MANUFACTURING FOR GARMENT INDUSTRY AND BASEMENT STORAGE TO  ADAPTVE REUSE LIVE WORK UNITS. CHANGE OF USE OF PORTION OF FIRST FLOOR RESTAURANT AND RETAIL TO 8 JOINT LIVE AND WORK QUARTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41194	19041-20001-03979	602 W PARK ROW A	90012	1	139-5A217  71	5415030015	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural	Yes	2060.10	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Issued	02/07/2019 12:00:00 AM	ADDRESS	34.07672	-118.2314	02-07-2019 Changes to an approved set of plan, changes include reduce PV sysem size to 2.16KW with 6 AC  Modules for unit A.Fees $63.92 due to California Senat Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41195	15041-10008-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	Change to an approved set by modifying the lighting and power plan with new panel, equipment, ckts, and load added. Title 24 also being updated. All changes under delta 23 and 24 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41196	16041-10000-05925	143 N LARCHMONT BLVD	90004	4	138B189   782	5515019019	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Info Complete	02/19/2016 12:00:00 AM	ADDRESS	34.07426	-118.32382	PC FOR ENERGY ONLY. TAILORED METHOD. TI FOR (PRESERVE SUNGLESSES) RETAIL STORE. TOTAL AREA 325 SQ FT,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41197	19041-20001-21195	9000 N CORBIN AVE	91324	12	195B117    23	2783028047	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.23458	-118.56205	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. CHANGES MADE TO SINGLE LINE, CHANGE TO CONDUCTOR SIZES, REMOVAL OF INVERTER FUSES, AND UPDATE TO FEEDER SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41198	13041-10000-21096	11831 S JUNIETTE ST	90230	11	105B165   207	4220003043	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	PIN	33.98657022	-118.40307733	PV1 3.024KWac 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 14) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41199	17041-20000-34046	12744 N SAN FERNANDO ROAD BLDG 3	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for energy only. TI to existing commercial building - new restroom and new corridor lighting (incl. emergency) - 394sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41200	10041-10000-00782	220 W 5TH ST 1-72	90013	14	129A211    99	5149034001	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/15/2010 12:00:00 AM	01/28/2010 12:00:00 AM		Permit Finaled	06/23/2010 12:00:00 AM	ADDRESS	34.04766	-118.25045	Installing facade lighting fixtures on the Broadway  and 5th st sides of the buildingplan chk is for compliance with Tile 24 for outside lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41201	16041-10000-00909	12700 W MILLENNIUM # 50	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1. SOLAR ROOF MOUNTED SYSTEM USING AC MODULES TO A TRACT HOME. 6 AC MODULES AND  AN EXTRA CIRCUIT FOR AN AC MODULE SUPERVISOR MONITOR. TOTAL SIZE: 1.5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41202	15041-10000-29378	2051 N CUMMINGS DR	90027	4	151-5A195 137	5589003014	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.10868	-118.30205	PV1 ADDITION 1.995 KW DC SOLAR ARRAY TO AN EXISTING 7.350 KW DC SYSTEM ON  A SINGLE FAMILY DWELLING.(7) MODULES: SOLAR WORLD SE 285 MONO (7)  ENPHASE M250-60-2LL-S22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41203	11041-20000-05615	6033 W CENTURY BLVD # 110	90045	11	090B169    17	4124030037	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	05/16/2011 12:00:00 AM	ADDRESS	33.94572	-118.38954	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T.I. FOR OFFICE ON 1ST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41204	18041-10000-06478	400 S BROADWAY	90013	14	129A211   293	5149024***	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/21/2020 12:00:00 AM	ADDRESS	34.04925	-118.24934	PC FOR TEMP POWER. SCOPE INCLUDES TWO SERVICES 480/277 3P 1000A EACH. WITH NEW EQUIPMENT.SEE 18041-10000-03110 FOR ACTUAL PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41205	17041-10000-40526	5414 S CRENSHAW BLVD	90043	8	108B185   430	5006008026	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.99262	-118.33045	NEW 70 UNIT AFFORDABLE SENIOR HOUSING APARTMENT 4 STORY OVER 1 STORY  PARKING GARAGE AND RETAIL WITH NEW 2000AMP, 120/208 V, 3PH SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41206	19041-10000-33844	24177 S STERLING RANCH ROAD	91304	12	192B089   185	2017011013	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Chatsworth - Porter Ranch	West Hills	YES	1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.21966	-118.65388	[EPLAN] PLAN CHECLK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIVIA 7.6TL) WITH 24 MODULES(320W SC STD MODULES) USING RAPID SHUTDOWN DEVICES CONNETED TO EXISTING 400A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41207	14041-10001-22168	1501 N MAIN ST	90012		136-5A217 147	5409003042							Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	11/17/2014 12:00:00 AM	PIN	34.06690042	-118.22937525	Expedite fee only for solar system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41208	15041-10000-11812	6030 S SEABLUFF DR 1-75	90094	11	102B157   327	4211021042	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/21/2015 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	33.97298	-118.42231	New methane gas detection system for a (3) story, 71-unit partment. Scope includes (1) control panel, (1) communication panel, (17 ) sensors and (10) fire alarm devices. Designed to Playa vista, phase 1 design level 3 similar to a  site design level V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41209	17041-30006-43250	223 S LOS ANGELES ST	90012	14	130-5A213 153	5161026040	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			PC Approved	05/24/2018 12:00:00 AM	ADDRESS	34.04986	-118.24401	Energy plan check for a lost plan. Total area is 1171-SQ FT. The application is for plan check only, permit is paid under 17041-10000-43250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41210	14041-20001-30437	642 E 118TH ST	90059	15	084B205   720	6084004009	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	33.92632	-118.26379	8/27/15 CHANGES TO APPROVED SET OF PLANS. CHANGES TO SINGLE LINE TO REFLECT MAIN SERVICE EQUIPMENT ON FIELD.((PV1Install a roof-mounted solar array on a SFD. Interconnect with 100A MSP.System size: 3.44kW.16 EnPhase M215 microinverters attached to 16  250W pv modules.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41211	13041-10000-34539	3643 N LOWRY ROAD	90027	4	154-5A203 157	5592010003	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Corrections Issued	01/28/2014 12:00:00 AM	ADDRESS	34.11766	-118.2778	PV1, Install 4.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (18) modules[YINGLI # YL250P-29b] on a 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41212	16041-10001-36637	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019007	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.25776	-118.46707	"CHANGES TO APPROVED SET OF PLANS UNDER DELTA 28, 30. SCOPE INCLUDES REVISED ""LDP"" TO REFLECT ALL CONNECTED LOAD ON SWITCH BOARD SCHEDULE. REVISION TO LIGHTING AND T-24 TO REFLECT CORRECT FIXTURE INSTALLTION. THIS IS PLAN CHECK ONLY!!"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41213	19041-10000-23927	18362 W OXNARD ST BLD. 1	91356	3	177B125   753	2157002134	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Closed	04/26/2022 12:00:00 AM	ADDRESS	34.17985	-118.53311	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES NEW 600A SERVICE 120/208V AND ASSOCIATED EQUIPMENT- TOTAL NEW CONNECTED LOAD OF APPROX. 400A. TOTAL AFFECTED AREA 307 SF.SEE NOTES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41214	19041-20000-01629	929 E 2ND ST	90012	14	129A217    96	5163004007	(T)(Q)C2-2-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM			Reviewed by Supervisor	03/20/2019 12:00:00 AM	ADDRESS	34.04727	-118.23429	Plan check for power and energy High-Rise Building addtion of 5 levels to existing 2 story building Mix use building core and shell space retail +Automated Parking System. 5000A  277/480V Service B#18014-10000-06684	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41215	10041-20000-20012	7060 W HOLLYWOOD BLVD 7th floor	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.10137	-118.34379	T.I. existing high rise building at office space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41216	16041-20000-33644	18355 S FIGUEROA ST	90248	15	063B201   204	7339008036	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	33.86489	-118.28185	Remove existing hid fixtures ans replace with led fixtures outdoors.  plan check for energy only.  total square footage 139750.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41217	13041-10000-10816	6245 W 87TH ST	90045	11	096B165   717	4123003026	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM	04/19/2016 12:00:00 AM		Issued	04/19/2016 12:00:00 AM	ADDRESS	33.95867	-118.39444	PLAN CHECK POWER AND ENERGY. TENANT IMPROVEMENT TO EXPAND EXISTING RESTAURANT. NEW 600A SERVICE.3rd extension - 4/13/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41218	15041-20000-26443	8361 N LULLABY LANE	91402	6	192B153   562	2638023022	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.22334	-118.44524	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel. (24) Kyocera KU 265 Modules(1) PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41219	18041-10000-13385	2666 W OLYMPIC BLVD #101	90006	1	129B197   273	5076009005	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.0522	-118.28994	TI IN AN EXISTING COMMERCIAL AREA.OLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41220	17041-10001-46374	2600 S CATALINA ST	90007	8	123B197   906	5054028018	[Q]C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Apartment			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.03245	-118.29412	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 1, SCOPE OF WORK IS CLARIFYING THE METHANE LEVEL (EXMEPT FROM METHANE MITIGATION, METHANE REPORT HAS BEEN PROVIDEED), GOING FROM SIEMENS TO SQUARE D BREAKER, AND FAULT CURRENT LETTER HAS BEEN PROVIDED.  ALL PERMIT FEES TO BE PULLED UNDER MATER PERMIT 17041-10001-46374-----------------------------ORIGINAL SCOPE OF WORK----------------------------------PC FOR POWER AND ENERGY FOR NEW 3-STORY MULTI-FAMILY RESIDENTIAL BUILDING OVER PARKING 15 UNITS PROPOSED.SCOPE INCLUDES NEW SERVICE 1200A 120/208 3PH IN A METHANE BUFFER ZONE. 6 TYPICAL UNITS WITH  AFFECTED AREA OF 11520 SQ.FTELECTRIC CAR CHARGER NOT PROVIDED AT SUBMITTAL.B#17010-10000-05120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41221	17041-10001-28606	12229 W PICO BLVD	90064	11	120B149    46	4259029009	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.02871	-118.45202	Changes to an approved set of plans. All changes are clouded under Delta 2. Changes include replacing emergency lights with bug eyes, replacing lighting fixtures, revising title 24 calculations, and revisting emergency photometrics. Note: Permit is paid under express permit PCIS#17041-30000-24773	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41222	18041-10000-30595	14001 W OSBORNE ST	91331	6	195B153   210	2642031021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.23346	-118.43824	NEW FIRE ALARM SYSTEM IN A COMMERCIAL BLDG. TOTAL OF 16 FA DEVICES AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41223	14041-10000-30227	5600 W WILSHIRE BLVD Suite G	90036	4	132B181  1296	5089006***	(Q)C2-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.06214	-118.35085	Title 24 plan check only.  Total area = 1068 SQ feet.  commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41224	16041-10001-42936	17425 W DEARBORN ST	91325	12	198B129   336	2766011041	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.23726	-118.51443	Expedite per applicant request{{{{{Plan check for PV roof mounted system size: 13.8kW with 50 modules and 3 inverters(4.6kW) NINGBO GINLONG TECHNOLOGIES : SOLIS-4.6-2G-US. Connected to existing MSP 200A}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41225	13041-20001-22284	9074 W SHOREHAM DR PV-1	90069	4	144B169   527	5560034008	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.09127	-118.39075	EXPEDITE FEE.PV-1. MIcroninverters 3.23kW total AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41226	13041-10001-35512	2307 S THURMAN AVE	90016	10	123B173    54	5064025019	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.03706	-118.36686	Expedited RSES plan check per applicant request.{{PV1, Install 2 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (8) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41227	17041-10000-01972	1729 E WASHINGTON BLVD	90021	14	118-5A213  12	5167002058	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.02059	-118.24186	T24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, TOTAL AREA 10500 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41228	14041-10000-11753	4010 S COMPTON AVE	90011	9	115-5A211 154	5117013005	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Expired	05/26/2016 12:00:00 AM	ADDRESS	34.01063	-118.24957	T24, Remove HID light fixtures and replace with new florescent fixtures.  Total area 4548 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41229	19041-20000-24274	20612 W BLUEBIRD CT pv1	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.29689	-118.58257	pv1install roof mounted pv system sized 5.25KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41230	11041-10000-27250	110 N GEORGE BURNS ROAD #1057	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.07564	-118.38149	Plan check T24 Energy/Emergency lighting for Research Center Lab Suite #1057. No patient care area. Existing permit under #11041-20000-24540. Additional permit to include new branch ckts and light fixtures on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41231	18041-10000-11405	1837 N MANDEVILLE CANYON ROAD	90049	11	135B137   223	4426007012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.06782	-118.4942	PC for four new Tesla Powerwalls for SFD and 125A load center and 200A distribution panel. Total system size is 23.2kW and 54KWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41232	17041-20001-44042	23115 W SHERMAN PL	91307	12	183B097    55	2021014044	CR-1VL, P-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.20115	-118.63061	10/9/2018changes to an approved set of plans.  changes noted delta 1 only.  changes to reflect fiels conditions.  this is plan check only.  ((((ti to an existing medical clinic, first time tenant.  plan check for power and energy.  NON-OSHPD-3BUILDING APPLICATION NUMBER 17016-20000-35070))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41233	17041-10003-19822	17541 W LANARK ST	91325	12	189B129    82	2201006009	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.21808	-118.51567	Supplemental PC for changes to approved set. Changing location of powerwall and disconnect. This is plan check only, permit is under the master 17041-10000-19822	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41234	10041-20000-14252	7060 W HOLLYWOOD BLVD 8th fl	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	energy plan check 8th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41235	15041-10000-38121	11704 N PRAGER AVE	91342	7	213B165   196	2531026047	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.28268	-118.3963	PV1, INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (16) MODULES:HANWHA Q CELLS Q-PRO BFR-G4 260(16) MICROINVERTER: ENPHASE ENERGYM215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41236	12041-20000-06747	22653 W WATERBURY ST	91364	3	165B097   364	2078007008	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2012 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	05/10/2012 12:00:00 AM	ADDRESS	34.14862	-118.61978	Roof mounted photovoltaic system for SFD, 8.99KW. a	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41237	19041-20000-48241	19665 W LOS ALIMOS ST	91311	12	210B117   313	2708022029	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.26841	-118.56225	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM, SYSTEM SIZE IS 14.8 KW DC STC/13.488 KW AC CEC. SCOPE OF WORK CONSISTS OF (40) PV MODULES WITH OTPIMZERS AND A 11.4 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41238	18041-10000-45889	14530 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.23519	-118.44861	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41239	17041-20001-30164	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.21445	-118.48429	4/4/2018changes to an approved set of plans.  changes noted delta 1.  changes to downsize total system size to 360kw AC.  Roof mounted portion of the system is 300kw AC consisting of (5) inverters, (860) modules, and (1) load center.This is plan check only.(((Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size is 400 kWac. Roof-mounted portion of the system is 276 kWac and consists of (5) inverters, (860) modules, and (1) load centers.Note: $0.00 permit fee due to CA Senate Bill 1222. Ground-mounted portion of the system has application number 17041-20000-30167 and has building application number 17010-30000-03239.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41240	13041-20000-16573	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM			PC Info Complete	06/26/2013 12:00:00 AM	PIN	33.92817449	-118.43220714	RENOVATION OF SOME CABLES AT HYPERION WATER TREATMENT CENTER. LOCATION IN HAZARDOUS, CLASSIFIED MATERIALS LOCATION. PC FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41241	18041-10001-06932	18050 W CHATSWORTH ST	91344	12	207B125   637	2731008023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.26455	-118.52561	"CHANGES TO APPROVED SET OF PLAN - CHANGES INCLUDE RELOCATION OF OVERRIDE SWITCHES TO FRONT OF RETAIL SPACE AND IN ELECTRICAL ROOM - CHANGES ARE UNDER DELTA 1 ONLY. Full plan check for first time retail tenant ""Ross"", install new panels, new lighting and power receptacles. Total area: 22,923 sq.ft, T24 form using performance method. B# 18016-10000-05853"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41242	11041-20000-21156	4180 S MARCASEL AVE	90066	11	111B157   812	4233014007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	12/28/2011 12:00:00 AM	ADDRESS	33.99889	-118.42135	Installation of a 2.55 KWDC solar system on a single family residence.  A variance to use M215 has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41243	12041-10000-15486	17450 W MAYERLING ST	91344	12	213B129    98	2607010024	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.28297	-118.51472	Plan Check for roof mounted photovoltaic system. 4.8kW DC. Enphase M215 Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41244	17041-30001-09846	7373 W BEVERLY BLVD	90036	5	138B181   398	5526037016	C2-1VL-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	34.07631	-118.35069	04/20/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Title 24 plan check.  TI and change of use from retail to office.  All subpanels to remain existing.  New lighting and receptacle loads.  Total area = 5,435 sq. ft.Building permit #17016-40000-00589	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41245	12041-10000-05663	7851 W SUNSET BLVD	90046	4	147B177   972	5551019022	C4-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.09823	-118.36076	T24 ENERGY AND EMERGENCY LIGHTING. EXISTING RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41246	14041-20000-03275	10940 W VICTORY BLVD	91606	2	180B173   884	2414001002	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.18652	-118.36952	Install general/emergency lights in 1st floor hallway.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41247	16041-10000-17539	12930 W VENTURA BLVD 114	91604	2	165B161  1036	2385026024	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.14513	-118.41481	TI TO NEW JUICE BAR. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41248	18041-10000-45294	11635 W SHELDON ST	91352	6	201B169   103	2537023015	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Reviewed by Supervisor	12/12/2018 12:00:00 AM	ADDRESS	34.24543	-118.38567	NEW ROOFTOP MOUNTED 12 KVA PV SYSTEM ON (E) COMMERCIAL BUILDING(38) MODULES, (1) 12 KVA  AC SYMO 12.0-3 INVERTER1 OF 2 PV SYSTEMS ON SAME BUILDING, OTHER ON PERMIT #18041-10000-45299	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41249	14041-20000-15486	4319 N LA BARCA DR	91356	3	165B117   247	2177005041	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.149	-118.55141	(($0 permit fee due to senate bill 1222 from 2012))PV1.  Install 15.045 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41250	19041-20000-03966	3455 S SAINT SUSAN PL	90066	11	117B157   568	4249025021	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.01558	-118.42904	Plan  check for PV roof mounted and battery back up system, PV system 5.22kW DC, 7.6kW AC with 18 PV Modules and 1 inverter(7.6kW) and 1 LG Chem Battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41251	18041-10000-01976	2847 W LEEWARD AVE	90005	1	133-5A201 214	5077015011	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	10/07/2020 12:00:00 AM		Permit Finaled	12/11/2023 12:00:00 AM	ADDRESS	34.05886	-118.28554	New 6-story, Type IIIA, 46-unit apartment building over 1-story & 2 subterranean, Type IA, parking garages. Scope includes a new 2000A 120/208 3 phase 4 wire service/distribution board, new panel, and circuits.  B#17010-10000-02733	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41252	19041-10000-34378	333 S GRAND AVE 49TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.05271	-118.25179	T-24 PLAN CHECK FOR A TI TO AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 12,403 SQ.FTB# 19016-10000-23542	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41253	15041-10000-01307	639 N LARCHMONT BLVD	90004	4	141B189   437	5523012027	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	34.08288	-118.32397	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41254	12041-10000-31050	1711 E SLAUSON AVE	90058	9	108B213   674	5105021030	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM			PC Approved	12/28/2012 12:00:00 AM	ADDRESS	33.98968	-118.24274	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS 7266 SQUARE FEET (<30,000). COMMERCIAL REMODEL LIGHTING AND REWIRE. (CIVIL ENGINEER SIGNED PLANS, WORK IS SUPPLEMENTARY TO CIVIL ENGINEERING WORK PER APPLICANT).   PERMIT WAS ISSUED UNDER A DIFFERENT APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41255	14041-20000-19384	7640 N TAMPA AVE F	91335	3	186B117    83	2104012066	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.20967	-118.55333	Plan check for power and energy on a TI blood draw office in a medical center building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41256	13041-10000-34890	1300 S SAN PEDRO ST ste #121	90021	14	123A211    69	5132019001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	PIN	34.03251075	-118.25377188	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 448 SQ FT. TOTAL OF (3) UNITS WILL BE REPLACED.ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41257	19041-10000-19432	13124 S FIGUEROA ST	90061	15	078B201    42	6132012036	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	33.91259	-118.28252	T-24 PLAN CHECK FOR A TI OF AN EXISTING PARKING GARAGE AREA. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 3809 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41258	15041-10000-12233	218 S MAIN ST	90291	11	111B141   507	4286003021	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	33.99733	-118.47869	Change of use from retail to restaurant and associated TI work.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41259	18041-10000-21191	5603 S CENTRAL AVE	90011	9	108B209  1119	5103016030	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	33.99131	-118.2567	PERMIT 16041-10000-02111 WAS FINALED FOR NEW RETAIL BUILDING TO BE SUBDIVIDED INTO 6 EA TENANT SPACESPLAN CHECK IS TO HAVE ONE TENANT AND ADDING NEW CIRCUITS AND  LIGHTING FOR EXISTING SPACE .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41260	17041-10000-08077	1327 E 15TH ST	90021	14	121-5A213 148	5130011035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.02678	-118.24703	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 10325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41261	14041-10001-06406	20790 W NORDHOFF ST BLDG 2	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM				Change to approved set by upgrading the main service equipment from 800-Amp to 2500-Amp with new location. (2) new AV charger stattions and Emergency lighting also added to the plan.All changes are under delta-8 only.(((NEW CORE & SHELL FOR FUTURE COMMERCIAL BLDG. EPC IS FOR POWER & ENERGY. BLDG#14010-10000-00744. This building is designed as a core and shell building only; separate building, electrical, and mechanical permits are required for all future residential unit build-outs or commercial tenant space  build-outs.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41262	18041-10000-48171	2216 S PACIFIC AVE	90731	15	009B197   102	7465003003	C2-1XL-CPIO	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM			Corrections Issued	05/15/2019 12:00:00 AM	ADDRESS	33.7239	-118.28781	Plan check for energy only to a change of use to retail space. Scope of work includes new circuits and lighting using performance method for T-24 calculations. Total sq. ft. 1490.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41263	17041-10002-24311	1180 S BEVERLY DR	90035	5	132A167   184	4330031026		West Los Angeles				2691.00	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM			PC Approved	06/25/2018 12:00:00 AM	ADDRESS	34.05581	-118.39554	PC FOR CHANGES TO AN APPROVED SET UNDER DELTA 11.REMOVAL OF FACP FROM FLOOR PLAN AND PANEL SCHEDULE.  THIS IS PLAN CHECK ONLY!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41264	11041-20000-10109	14950 W OXNARD ST	91411	2	177B145   472	2243022019	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	ADDRESS	34.17917	-118.45903	PLAN CHECK T24 ENERGY INDOOR AND OUTDOOR LIGHTING FOR AUTO BODY SHOP. PERMIT FOR NEW, PANEL, CKTS AND EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41265	17041-20000-38906	145 E 35TH ST	90011	9	118-5A205 280	5120006007	M1-1, [T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Closed	07/22/2020 12:00:00 AM	ADDRESS	34.0173	-118.27168	PLANCHECK FOR POWER. SERVICE UPGRADE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41266	13041-10007-34279	21720 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Closed	08/10/2016 12:00:00 AM	ADDRESS	34.18733	-118.60234	Delta 90 change on the site plans-addition of 5HP sump pump	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41267	19041-10000-47738	1150 S OLIVE ST 27TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.03962	-118.26181	TITLE 24 PLAN CHECK (ENERGY) ONLY.  AREA SQUARE FOOTAGE: 15688	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41268	11041-10000-07063	11150 W SANTA MONICA BLVD	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM			PC Approved	04/08/2011 12:00:00 AM	ADDRESS	34.04704	-118.44563	Ti in an existing office Bldg. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41269	12041-20000-24869	21711 W VENTURA BLVD	91367	3	174B105    61	2168027032	(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	PIN	34.16908754	-118.60110998	Assisted living senior care (93.0206 (b) 3 and Article 517) . Full plan check and title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41270	11041-10000-09249	1498 W SUNSET BLVD	90026	1	139-5A209 287	5405001034	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	05/23/2011 12:00:00 AM	ADDRESS	34.0756	-118.25514	Ti in a retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41271	14041-20000-17765	18539 W VENTURA BLVD	91356	3	174B125   581	2160007029	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Closed	12/22/2014 12:00:00 AM	ADDRESS	34.16946	-118.53722	pc for T24 energy only. Fire damaged builindg. new lighitng.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41272	19041-10000-32770	3030 W OLYMPIC BLVD SUITE #113	90006	10	129B193   316	5080033029	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM			PC Info Complete	08/21/2019 12:00:00 AM	ADDRESS	34.0524	-118.3013	ENERGY PC CHANGE OF USE FROM RETAIL/BAKERY TO RETAIL. AREA 816SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41273	13041-20000-22595	7002 N MIDDLESBURY RIDGE CIR	91307	12	183B089   371	2028045003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.19751	-118.64655	PV1 TRANSFORMERLESS SYSTEM 3.5KW. 14 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41274	16041-20001-26778	450 S ST ANDREWS PL	90020	4	135B193   629	5503016080	R4-1	Central	Wilshire	Greater Wilshire		2117.03	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.06561	-118.31141	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 56kW with 211 modules and 4 inverters(14.0kW) connecteted to 3 phase MSP}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41275	10041-20000-06175	7325 N MEDICAL CENTER DR suite 203	91307	3	186B097   830	2021014040	(Q)CR-1VL, CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.20328	-118.62963	medical office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41276	10041-20000-16196	3494 E PICO BLVD 1 ST FLOOR	90023	14	118-5A225 320	5190036804	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.0179	-118.20314	replace a/c units and c/b on existing generator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41277	19041-10000-41145	2636 N FIGUEROA ST	90065	1	142-5A219 135	5446017012	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	34.08451	-118.22126	REMOVE HID FIXTURE AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41278	19041-10000-00472	9044 N GLORIA AVE	91343	12	195B141    23	2672005039	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.23508	-118.48056	PLAN CHECK FOR ROOFTOP MOUNTED 7.150 kw DC PV SYSTEM WITH (22) MODULES , (1) AC INVERTER WITH 7.6 KW,  (22) POWER OPTIMIZER P370.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41279	13041-10000-34278	8444 W MELROSE PL	90069	5	141B173   509	5528017031	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.08341	-118.37479	PLAN CHECK FOR POWER AND ENERGY; TENANT TO A TWO-STORY RETAIL SPACE. PROJECTED AREA OF LIGHTING WORK IS APPROXIMATELY 2696 SQ FT, AND INCLUDES EMERGENCY LIGHTING. OCCUPANT LOAD OF 122 PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41280	10041-10000-17309	243 S SAN PEDRO ST	90012	9	129A213   469	5161024***	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	34.04832	-118.24246	CHANGE OF USE FROM  (E) RETAIL TO (N) RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41281	13041-20000-33230	1701 S BUCKINGHAM ROAD	90019	10	126B185   334	5071010024	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Info Complete	11/26/2013 12:00:00 AM	ADDRESS	34.04361	-118.33444	PV1 MICORINVERTER STANDARD PLAN. 32 MODULES AND MICROINVERTERS. TOTAL SYSTEM SIZE 6.192 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41282	17041-20001-03174	9700 N DONNA AVE	91324	12	201B121   411	2762032030	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM			PC Approved	02/23/2017 12:00:00 AM	ADDRESS	34.24716	-118.54739	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41283	18041-20000-28338	1800 S CENTURY PARK EAST 4TH FLR	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.06244	-118.41523	Plan check for Title 24 only  in existing high-rise building 4th Floor Restroom remodeling. Total area: 335 sq ft. 18016-10000-13131	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41284	18041-10000-21822	3350 W WILSHIRE BLVD 1-216	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.04	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	11/25/2020 12:00:00 AM	ADDRESS	34.0615	-118.29586	PC FOR TEMP POWER ON EXISTING DISTRIBUITION PER INSPECTION. SCOPE INCLUDES NEW SWITCHGEAR 600A WITH 225KVA TRANFORMER AND OTHER PANELS AND CIRCUITS. TOTAL CONNECTED LOAD <400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41285	13041-10000-13699	12427 W ROCHEDALE LANE PV1	90049	11	138B137   357	4494009008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Expired	06/22/2015 12:00:00 AM	ADDRESS	34.07329	-118.48622	PV1 9.36 KW XFMR INV. 1 STORY HOUSE. STD. ROOFMOUNT.  [(1) INV: sunnyboy 7000-US ][(36) MOD: YGE240 series ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41286	14041-20000-34562	10936 W CHALON ROAD	90077	5	141B149    50	4369020001	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.08466	-118.45742	PV1 SFD. THIS IS A GROUND MOUNT SYSTEM. TOTAL SYSTEM SIZE 21.5KW AC USING MICROINVERTER SYSTEM. USING ENPHASE M215. 100 MODULES IN TOTAL. SYSTEM INTERCONNECTS WITH EXISTING SERVICE. zoning completed from building permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41287	11041-10003-23439	20600 W VENTURA BLVD North-1-123	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			10/14/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.16715	-118.58204	DELTA 12 CHANGES TO PERMITTED SET OF PLANS(INSPECTION OF ORIGINAL PERMIT CONTINUES)North Building of a New 123 unit Apartment building with Commercial space.  1200A service for Commercial space and 2000A service for apartment space.  Building Permit is 11010-10000-01958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41288	10041-20000-04420	3825 S GRAND AVE	90037	9	117A203   162	5122026013	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM			PC Approved	03/15/2010 12:00:00 AM	ADDRESS	34.0146	-118.27998	Energyexist.permit 10041-90000-03501	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41289	19041-10000-25517	9825 W ALTMAN AVE	90034	5	123B165    84	4311001020	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.03662	-118.39897	[e-plan] INSTALLATION OF 2 NEW ESS(TESLA POWER WALL) TO EXISTING PV SYSTEM WITH LOAD CENTER .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41290	15041-20000-07432	3800 S WESTERN AVE	90062	8	117B193   782	5036008006	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.01723	-118.30873	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 22.8KW INTERCONNECTED WITH 400A MSP. GROUNDED SYSTEM.(88) QCELL Q.PRO-G3 260W MODULES(2) FRONIUS 11.4 UNI INVERTERSNote: Solar clearance obtained under previous set of plans under permit #14041-20000-35638. This plan is being resubmitted due to the system being redesigned under request of DWP (reducing wattage from 33.8kW to 22.8kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41291	13041-20000-29223	670 N PERUGIA WAY	90077	5	141B149   162	4362003017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.08163	-118.45004	PC FOR SINGLE FAMILY DWELLING. 600A SERVICE. NEW CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41292	14041-20000-02291	9019 N HASKELL AVE	91343	12	195B141    97	2672006044	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.23424	-118.47653	PV1 SINGEL FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41293	10041-20000-12078	15910 W VENTURA BLVD 1605-1610	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	34.15561	-118.47969	T.I. TO RELOCATE DEMISING WALL BETWEEN TWO EXISTING OFFICE SPACES(ENLARGE SUITE# 1610 BY 1050SF(TOTALING 3720SF) AND REDUCE SUITE# 1605 BY 1050SF).  ENERGY , EMERGENCYFire /Life safety s by others	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41294	14041-10000-15504	355 S GRAND AVE	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.05191	-118.2525	Title 24 plan check only for existing high rise.  Total area = 1,435 sq. ft.Replace existing lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41295	17041-20001-33642	11384 W VENTURA BLVD	91604	2	162B173   601	2378021022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.13978	-118.37862	Plan review for Title 24 Part 6.  (((RECEPTICLES OFF OF (E) CIRCUIT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41296	11041-10002-23664	808 N NORTH SPRING ST	90012	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM			PC Approved	10/30/2012 12:00:00 AM	ADDRESS	34.06198	-118.23674	PLAN CHECK FOR REVISION TO APPROVED PLANS. REVISE INSTALLATION ON SINGLE LINE TO SHOW 100A RATED ATS AND 100A RATED EMERGENCY DISTRIBUTION BOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41297	15041-20000-04734	4359 E TOLAND WAY	90041		156A221   131	5474024001							Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	34.12202	-118.22067	HARDSCAPE LIGHTING FOR TOWNHOMES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41298	15041-10000-05404	1400 S FIGUEROA ST	90015	14	126A205   122	5134009016	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			02/24/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	09/11/2023 12:00:00 AM	ADDRESS	34.03868	-118.269	NEW 110 UNIT APARTMENT COMPLEX, 7 STORIES WITH 2 LEVELS OF SUBTERRANEAN PARKING, AND GROUND FLOOR RETAIL.  (2) SERVICES, PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41299	19041-20000-50399	4973 N NOELINE AVE	91436	5	168B137    45	2260006022	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.16064	-118.49007	Plan check for PV roof mounted system PV System size: 10.88KW with 32 PV Modules and 1 inverter(10KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41300	12041-10000-11420	3491 N NORTH KNOLL DR	90068	4	159B185    69	5579025020	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	ADDRESS	34.1319	-118.33973	Plan check for new roof mounted 7.2KW Enphase M215 Microinverter photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41301	18041-20000-22234	2215 W MARTIN LUTHER KING, JR BLVD	90008	8	114B189   308	5035004028	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress North Area		2340.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.01099	-118.31772	Interior remodel of (E) commercial restaurant space.  Lighting upgrades in dining and restroom areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41302	19041-10000-05327	9445 N DE SOTO AVE	91311	12	198B109    61	2746008013	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.24204	-118.58882	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41303	14041-20000-21761	20000 W MAYALL ST	91311	12	204B113   500	2726022007	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.25351	-118.56923	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 6kW.(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(29) Trina Solar #TSM-255PA05.18 pv modules(29) Solar Edge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41304	12041-10000-30863	8378 W MELROSE AVE	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.08341	-118.37285	T24 for existing retail building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41305	15041-20000-33270	10250 W CONSTELLATION BLVD 12 Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 only for existing high-rise building corridor area on the 12th floor. Total area: 1,150 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41306	13041-10000-05455	8443 N VAN NUYS BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	34.2244	-118.44897	PV2 Plan check for roof mounted 299.04 KW Photovoltaic System at Panarama City Mall. Inverter output interconnection at supply side.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41307	14041-20001-26393	613 S SPRING ST FIRST FLOO-R	90014	14	129A211   246	5144002016	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	34.04569	-118.25144	[[[[[ CHANGES TO APPROVED SET. PLANCHECK ONLY, CHANGES TO T24 LIGHTING ONLY. MASTER PLAN CHECK WAS FOR T24 ONLY.]]]]]]]PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE FROM LAUNDRY TO RESTAURANT.  HIGHRISE. 2000 SQFT.    EMERGENCY LIGHTING INSTALLED WITH 90 MIN BATTERY BACK UPS. BUILDING NOT PART OF GENERATOR RETROFIT. RESIDENTIAL OCCUPANCY NOT BEING CHANGED.  INSPECTOR TO VERIFY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41308	11041-20001-20387	8158 W BEVERLY BLVD	90048	5	138B173   448	5511006031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	ADDRESS	34.07591	-118.36736	Delta 3 modification only, to install exterior lighting sytem.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41309	16041-20001-23803	883 W 9TH ST	90731	15	015B197   863	7454008002	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	33.73594	-118.29639	01/04/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES.  2713 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41310	11041-10000-03272	200 N BARODA DR	90077	5	141B157    73	4358005011	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2011 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	09/15/2011 12:00:00 AM	ADDRESS	34.0819	-118.42854	600 ampere service upgrade for single family dwelling.  supply new and existing equipment.  No new load to be installed at this time.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41311	15041-20000-12115	11507 W OXNARD ST #5	91606	2	177B169   797	2338004012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.1796	-118.38271	CHG OF USE FROM OFFICE TO MEDICAL OFFICE AT 2ND FLOOR; pc for power and energy. per art 517 health care. new lights, power and patient rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41312	17041-30000-36682	832 S PLYMOUTH BLVD	90005	4	132B189   457	5090028009	[Q]R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.0589	-118.32416	Plan check for PV roof mounted system of SFD. Total system size: 12.960 KW with 36 AC Modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41313	16041-30000-31117	18743 W SHERMAN WAY #7	91335	3	183B121   113	2118026015	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.20127	-118.54186	Plan check for Title 24 only in existing space, replace indoor HID fixture with LED fixture. Total area: 1,380 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41314	13041-10000-26452	4729 N EAGLE ROCK BLVD	90041	14	159A221    95	5685027016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.13117	-118.21666	CHANGES TO APPROVED SET OF PLAN.  DELTA 4 CHANGES HAVE BEEN CLOUDED. TITLE 24 PLAN CHECK ONLY. APPROVED PLAN CHECK UNDER. 13041-10001-13638. TI TO EXISTING BLDG. RETAIL TO RESTAURANT. max city bbq	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41315	14041-20001-09780	8914 N WHITE OAK AVE	91325	12	195B129   186	2768027006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.23294	-118.51983	((expedite fees)))pv1 single family. total system size 7.6 kw ac using 2 central transformerless inverters. nonstandard plan. total of 35 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41316	14041-10000-03305	777 W 190TH ST	90248	15	060B201    48	6121021006	[T][Q]M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	33.86037	-118.28753	PLAN CHECK FOR POWER AND ENERGY. SERVICE UPGRADE FOR 'PRIME AUTO' WHOLESALE. UPGRADING FROM 400A SERVICE TO 600A OVERHEAD 120/240, 1PH, 3WIRE SERVICE. ALL CKTS AND PANELS ARE EXISTING PER APPLICANT. 2 New feeders for Panel C and C1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41317	10041-20000-05865	1929 S BELOIT AVE 1-63	90025	11	126B153   502	4261031003	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	04/09/2011 12:00:00 AM	ADDRESS	34.04254	-118.44403	revise elevator size and add klow voltage outlet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41318	15041-20000-21741	6250 N TOPANGA CANYON BLVD F-1555	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for power and energy. Project scope is a first time tenant at the Westfield Village. Total lighting area = 900 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41319	15041-10000-23018	5311 S CRENSHAW BLVD	90043	8	108B185   165	5006006023	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	33.99449	-118.33114	New fire alarm system for a commerical building with 3-story. Scope includes (1) fire alarm panel, (3) power supplies, and (233) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41320	18041-20001-09463	22331 W MULHOLLAND DR	91364	3	165B101   218	2076024006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM			PC Approved	04/09/2018 12:00:00 AM	ADDRESS	34.14927	-118.61251	Supplemental PC for changes to approved set. Upsizing conductor size between j-box and inverter to #10.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41321	11041-10000-15953	1202 W ANAHEIM ST	90710	15	033B197    85	7411016026	[Q]C1.5-1VL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	33.78211	-118.29802	T.I.  Existing 7-11.  Renovation of the light fixtures in the retail area only.  Replacing light fixtures with LED's.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41322	16041-10000-22724	777 S FIGUEROA ST 2520	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.04828	-118.26116	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING FOR SUITE 2520. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 2286 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41323	13041-10000-01805	1101 W 28TH ST	90007	9	123A201   271	5055027001	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.02948	-118.28417	convert existing room at an apartment building to a laundry roomplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41324	18041-10000-48950	15350 W SHERMAN WAY	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	11/10/2020 12:00:00 AM	ADDRESS	34.20099	-118.46808	PLAN CHECK FOR NEW FIREALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 243 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41325	14041-10000-15992	4395 W SUNSET BLVD	90027	4	147A201   163	5542009025	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	PIN	34.09689522	-118.28487069	PC FOR POWER AND  ENERGY. CHANGE OF OFFICE TO TWO FLOOR  STUDIO. TOTAL  AREA 6386 SQ FT.<<PLAN CHECKER VERIFY THE # OF DEVICES. THE APPLICANT ASKED FOR ADDING 3 FIRE ALARM DEVICES THAT HAS TO BE PROCCESSED SEPARATELY. PER FRANCIS SUPERVISORY >>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41326	14041-20000-29874	12860 W RIVERSIDE DR	91604	4	168B161   422	2357033021	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Info Complete	04/30/2015 12:00:00 AM	PIN	34.15733931	-118.41348969	Plan check for power only. Adding new car wash to existing gas station -> Upgrading service to 800A, installing new distribution equipment, and reconnecting existing equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41327	12041-10000-16111	13438 W OXNARD ST	91401	2	177B157   881	2343021014	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.17926	-118.42606	Plan check roof mounted 6.72KW photovoltaic system (Sunpower transformerless inverter). PV modules and equipment located at the detached garage. PV interconnection to existing subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41328	17041-20000-45727	18334 W MALDEN ST	91325	12	192B125   203	2786007004	(Q)R3-1, R1-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Apartment			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	PIN	34.22512205	-118.53292311	Plan check for a fire alarm system for a 4-story, 22-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (82) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41329	19041-10001-48771			11	093B161     3	4119006913	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	PIN	33.95449649	-118.41592046	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED. CHANGES INCLUDE REMOVING TEMPORARY GENERATOR AND FEEDING TRAILERS/TEMPORARY EQUIPMENT TO AN EXISTING 2000A DISTRIBUTION BOARD.Note: PERMIT FEES ARE COVERED UNDER MASTER APPLICATION. PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41330	13041-10000-32752	1500 W PACIFIC COAST HWY BLDG F1	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING F1. THIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41331	18041-20001-49191	6522 N WINNETKA AVE	91367	3	180B113   593	2134037007	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.18896	-118.57073	Revisions to approved set.  Relocation of equipment on site plan.  $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((Plan check for PV roof mounted system, system size: 11.8kW DC, 10.0kW AC with 36 P V modules)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41332	16041-10000-14466	2029 S CENTURY PARK EAST STE 1300	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING FOR SUITE 1300. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 8870 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41333	16041-20000-25705	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Info Complete	11/09/2016 12:00:00 AM	ADDRESS	33.94955	-118.38342	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVENET FOR NEUTROGENA MANUFACTORING. ( 1 OF 3 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41334	10041-10000-07716	1345 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05072	-118.22407	INSTALLATION OF A  1.8 KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41335	15041-10000-43385	1303 W ANAHEIM ST	90744	15	030B201   196	7416003019	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Closed	01/23/2019 12:00:00 AM	ADDRESS	33.77925	-118.2784	CLEAN OUT TENANT SPACE. NEW LIGHTING AND PLUGS MAKE VANILLA SHELL. LEAVE AS TENANT LEASE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41336	14041-20001-16583	11620 W WILSHIRE BLVD 800	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	Plan check for modifications to approved set. Change photometric to correctly reflect fixture schedule. Replace all instances of fixture LF2 with fixture LF1.[Plan check for energy only. Suite 800. High rise with emergency lighting.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41337	16041-20000-25370	8111 N MARCH AVE	91304	12	189B093    76	2020009020	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.2173	-118.64272	PV1.  Install 12.099 kW roof mounted PV system.  (37) AC modules with (1) 100A subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41338	14041-20000-19233	8751 N WHITE OAK AVE	91325	12	195B129   338	2768012037	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM			Corrections Issued	07/21/2014 12:00:00 AM	ADDRESS	34.23016	-118.52026	PV1 - System redesign under new permit Install roof-mounted solar array on SFD. System size: 12kW(2) SolarEdge #SE6000A-US-ZB-U transformerless inverters(66) SolarEdge P300 power optimizers(66) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41339	14041-10000-13695	11165 W TENNESSEE AVE	90064	5	126B153  1071	4322024012	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.03817	-118.43775	T24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 5014 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41340	12041-10000-27409	5990 N SEPULVEDA BLVD	91411	2	177B145   487	2243019023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.17911	-118.46588	PLAN CHECK FOR TITLE 24 ONLY ON A TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41341	10041-10000-18425	3650 W MARTIN LUTHER KING, JR BLVD #268 B&C	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	10/15/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.01118	-118.33649	REMODEL OF T-MOBILE RETAIL STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41342	14041-20000-22811	20211 W SCHOOLCRAFT ST	91306	3	183B113   528	2135034018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.19668	-118.57363	PV1 SFD. USING CENTRAL TRANSFORMERLESS INVERTER. USING STANDARD PLAN. USING POWER OPTIMIZERS. TOTAL SYSTEM SIZE 6KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41343	16041-20000-42027	2132 N MAYVIEW DR	90027	4	148-5A203 322	5430008008	R1-1	Central	Hollywood	Los Feliz	Yes	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.10057	-118.27636	PV1Install roof mounted PV system with battery back up sized 7.6kw, interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41344	18041-30000-17830	6033 W CENTURY BLVD 7TH &-9TH	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	33.94572	-118.38954	PLAN CHECK FOR T24 ONLY, INSTALL NEW LIGHTINGS IN THE RESTROOM 7TH AND 9TH FLOOR, OF A HIGH RISE BUILDING.((B# 17016-10000-12758))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41345	16041-20001-42084	411 S BRISTOL AVE	90049	11	129B137   323	4406029016	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM			PC Approved	12/20/2016 12:00:00 AM	ADDRESS	34.05079	-118.48621	12.20.2016 - Plan check for modifications to the approved set of plans. Update SLD (sheet E6) to show correct breaker models for series rating. Changes clouded.===========Plan check for power only. Two-story addition and remodel to single-family dwelling w/attached garage => had to change service from 400A to 600A, per inspector request: plan check service, distribution equipment, and feeders (incl. for fault current) per engineered drawings. Combined building permit application #14014-10000-02787.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41346	11041-10000-02940	6500 W WILSHIRE BLVD # 1850	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM			PC Approved	02/15/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EM CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41347	13041-10001-04732	15502 W FRIAR ST PV1	91411	6	177B145    23	2242003015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.18559	-118.47193	(((( CHANGED INVERTER FROM CENTERAL INVERTER TO MICRO INVERTERS. *PERMIT FEES HAVE BEEN PAID ON APPLICATION#: 13041-10000-04732*. THIS IS A PLAN CHECK ONLY. SYSTEM SIZE UNCHANGED. [MICROINVERTER: ENPHASE M215-60-2LL] [SOLAR MODULE: MONOX LG255S1C-G3]))))))))INSTALL A SOLAR SYSTEM (3.8 KW)  Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41348	16041-10002-38684	9165 N GLENOAKS BLVD	91352	6	198B173   145	2408033038	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Approved	04/17/2017 12:00:00 AM	ADDRESS	34.23566	-118.37289	FINAL FEES = $0.00 DUE TO SENATE BILL 1222PV2 INSTALLATION OF NEW 60KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING. (150) MODULES: SUNPOWER SPR-X20-327-COM(2) INVERTERS: SMA AMERICA STP 30000TL-US-10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41349	19041-10000-48011	904 S NEW HAMPSHIRE AVE	90006	10	132B197   835	5094026017	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Apartment			11/20/2019 12:00:00 AM	10/07/2021 12:00:00 AM		Issued	10/07/2021 12:00:00 AM	ADDRESS	34.05568	-118.29273	FULL PC FOR A NEW BUILDING WITH A SERVICE OF 3000A (120/208 3P 4W) WITH A 230KW EMERGENCY GENERATOR, SCOPE INCLUDES TWO NEW ELEVATORS, AND ASSOCIATED ELECTRICAL DISTRIBUTION EUIPMENT. TOTAL AFFECTED AREA IS 35,064 SQFT. PER BUILDING PERMIT (((NEW 8-STORY, 63 UNITS APARTMENT BUILDING WITH GROUND LEVEL AND ONE SUBTERRANEAN LEVEL PARKING. TOC AFFORDABLE HOUSING PROJECT. B#19010-10000-04314)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41350	19041-20000-29978	5832 N TUJUNGA AVE #1-6	91601	2	174B173   160	2337014005	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Apartment			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.17687	-118.37885	Plan check for Title 24 only for 6 unit multi-family building, common area, outdoor and corridor only. Total area: 3774 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41351	17041-10001-40893	444 S FLOWER ST 6th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLAN CHECK FOR TITLE 24 ONLY. TOTAL AFFECTED AREA 632 SQ. FT. Note: Permit is paid under application PCIS#17041-90000-40893	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41352	14041-20000-03780	1458 N WESTERLY TER	90026	13	142-5A205 100	5425019013	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.0861	-118.27136	pv1 single family dwelling. total system size 3kw ac using transformerless inverters nonstandard plan. using 8 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41353	19041-10000-38044	3442 S CENTINELA AVE	90066	11	114B153   144	4248017033	[Q]R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	ADDRESS	34.01177	-118.43947	Power plan check for a 600-amp service upgrade. Scope includes rewiring all existing feeder for all residential and house panel. No new load added.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41354	16041-20000-00312	712 E 103RD ST	90002	8	091-5A207 279	6051003002	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	33.94318	-118.26201	Plan check for PV roof mounted system. System size: 2.5kW with 10 modules and 1 inverter(2.5kW) Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41355	16041-10000-30421	19903 W GRESHAM ST	91324	12	195B113   179	2782033027	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.23095	-118.56693	PV1, INSTALL 14.715 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(45) MODULES: SUNPOWER-SPR-e20-327-C-AC(45) MICROINVERTER:	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41356	15041-20000-23659	7246 N MCLAREN AVE	91307	12	186B097   950	2021017016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Expired	08/18/2017 12:00:00 AM	ADDRESS	34.2024	-118.62438	PV1. Install roof mounted PV system sized 6 kW. Interconneted with main service panel.(30) Kyocera KU2656(1) Fronius PVI 6.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41357	19041-20000-51411	132 S ROBERTSON BLVD	90048	5	138B169   438	4334005006	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.07447	-118.3836	Power and lighting for commercial tenant improvement.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41358	19041-10000-12053	16847 W VENTURA BLVD	91436	5	168B133    86	2259010001	C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.15927	-118.50037	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41359	15041-10000-42262	2867 W SUNSET PL	90005	10	133-5A201  80	5077013039	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Apartment			12/15/2015 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.0609	-118.2861	NEW FIRE ALARM SYSTEM 145 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41360	19041-20000-51933	1438 N GOWER ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM			PC Info Complete	12/17/2019 12:00:00 AM	ADDRESS	34.09714	-118.32212	T24 PLAN CHECK FOR ENERGY ONLY, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 350 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41361	19041-10000-08707	3511 S GRAMERCY PL	90018	8	120B189   949	5042030021	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.02417	-118.31395	Plan check for 3.8KW AC / 4.425 KW DC  roofmounted system with (1) inverter, (15) modules and optimizers interconntecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41362	19041-20000-46096	15451 W SAN FERNANDO MISSION BLVD	91345	7	210B145   127	2664007025	(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.27217	-118.46834	Installation of new FACP/elevator supervisory control panel with (7) signaling line devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41363	15041-10000-04557	18822 W PARTHENIA ST	91324	12	195B121   389	2785001081	[Q]M1-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.22808	-118.54338	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 5557 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41364	11041-10000-21549	2206 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.03796	-118.44083	Plan check power and energy. Revise feeders to swbd and provide provision for future tenants.Add (2) new lighting branch ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41365	11041-20000-15811	700 S SANTA FE AVE	90021	14	124-5A217 273	5166002011	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	ADDRESS	34.03435	-118.22981	PLAN CHECK T24 ENERGY/EMERGENCY FOR TAKE-OUT BAKERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41366	18041-10000-28172	340 S MAIN ST 1-3 floor	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.99519	-118.47673	T-24, PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCLUDES TENANT IMPROVEMENT TO (3) BREAKROOM SPACES. NEW LIGHTING AND RECEPTACLES TOTAL SQ. FT.  2440.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41367	14041-20001-23472	6957 N WISH AVE	91406	6	183B133   586	2230002024	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM			PC Approved	10/02/2014 12:00:00 AM	ADDRESS	34.19716	-118.50706	FEE CHARGE IS ZERO BY SENATE BILL NO.1222EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 9KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. DERATE MAIN BREAKER. SYSTEM USES 44 MODULES AND POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41368	14041-20001-24833	7010 S HOOVER ST Unit #2	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #2. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41369	10041-10000-00738	23130 W SHERMAN PL	91307	12	183B097   888	2026001907	(Q)CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Apartment			01/14/2010 12:00:00 AM			PC Approved	01/14/2010 12:00:00 AM	ADDRESS	34.2006	-118.63019	PER INSPECTOR GIBSON, PERMIT WAS CLOSED AND CONTRACTOR HAS CHANGED; 50% OF ORIGINALPERMIT FEE IS REQUIRED TO CONTINUE THE INSPECTION PROCESS; PLAN REVIEW IS FOR SMALL CHANGES TO APPROVED SET OF PLANS .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41370	18041-20000-44435	5401 N SEPULVEDA BLVD BLDG A	91411	4	172-5A145  22	2250001020	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	34.16854	-118.46653	PV2.  Install 53.95 kW roof mounted grid tied PV system.  (166) modules with (4) 11.4 kW rated string inverters.  System 1 of 2.$0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41371	12041-10000-31004	7507 W 90TH ST	90045	11	096B157   929	4119003018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	ADDRESS	33.95558	-118.4267	PV1 MICRO INVERTER SINGLE STORY HOUSE. [MIRCRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41372	19041-10000-06720	4247 N EAGLE ROCK BLVD	90065	14	156A219    67	5473024025	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.12274	-118.22392	"POWER AND ENERGY PC FOR A TENANT IMPROVEMENT OF (E) ""B"" GROUP VACANT SPACE, 1ST TIME TENANT. SCOPE INCLUDES NEW 200A PANEL CONNECTED TO AN EXISTING 2000A SERVICE, EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 880 CONDITIONED SQ.FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41373	12041-10000-16861	8654 N SUNLAND BLVD	91352	6	195B177   477	2404026003	C2-1VL, R1-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Apartment			07/19/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.22745	-118.3659	New Fire Alarm for a new 34 unit, 3-story, apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41374	14041-20000-01881	14802 W MORRISON ST	91403	4	169-5A149  65	2263029035	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Expired	02/29/2016 12:00:00 AM	ADDRESS	34.16021	-118.45545	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41375	17041-10000-35017	2801 S VINEYARD AVE	90016	10	123B181  1294	5057010013	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.0311	-118.34477	PC for roofmounted PV for apartment. Installing 8 pv modules and one 3kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41376	17041-10000-38192	10250 W SANTA MONICA BLVD #1430	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space ""VIDEO & AUDIO CENTER""  suite 1430"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41377	17041-10001-24720	1350 N IVAR AVE	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM				SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS UNDER DELTA #4 - CHANGES INCLUDE ADDING NEW FEEDERS FOR FUTURE FIREPUMPS WITH INTERCONNECTION TO DISTRIBUTION BOARD, LOCATION OF FIRE PUMP WITH SIZE AND CONDUIT ROUTING HAS BEEN APPROVED UNDER PC# 17041-10000-24720. <<PC FOR SHELL  AND CORE FOR MIXED-USE COMMERCIAL DEVELOPMENT WITH 3 LEVELS BELOW GRADE PARKING FOR POWER AND ENERGY.SCOPE INCLUDES 3 SERVICES :TWO  5000A 277/480 AND ONE 4000A 277/480TOTAL AFFECTED AREA (INDOOR +OUTDOOR)  680682+82107=762789 SQ.FT.>>B# 15010-10000-04706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41378	18041-20000-45791	1401 S ABBOT KINNEY BLVD	90291	11	108B145  1306	4241036001	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Issued	12/04/2018 12:00:00 AM	ADDRESS	33.99072	-118.46581	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41379	17041-10000-04264	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/12/2024 12:00:00 AM	ADDRESS	34.05134	-118.25661	T-24, PC FOR ENERGY ONLY. T.I. INTERIOR SPACE. REPLACE EXIT DOORS AND NEW FOLDING DOORS(CNP SOUTH LOBBY). TOTAL AFFECTED AREA IS 9260 SQ. FT. B#16016-10000-30717	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41380	15041-10000-02350	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.0484	-118.26248	PC for power and energy for EV chargers and lighting in electrical room and corridoors. Plan check for each tenant to be done at a later time.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41381	16041-20000-07660	12892 W KAMLOOPS ST	91331	7	204B161   573	2623026020	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.2538	-118.41341	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41382	17041-10000-45724	6420 N COLDWATER CANYON AVE	91606	2	180B161  1002	2325031007	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Issued	12/20/2017 12:00:00 AM	ADDRESS	34.18741	-118.41362	REPLACE METAL OUTDOOR HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41383	13041-10000-27813	350 S GRAND AVE # 1600	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	PIN	34.05160512	-118.25169569	TI IN CONFERENCE AND OFFICE ROOMSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41384	10041-20000-04693	1632 W COLORADO BLVD	90041	14	162A225    95	5689017003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	08/19/2010 12:00:00 AM	ADDRESS	34.13927	-118.20215	CHANGE OF USE FROM RESTAURANT TO RETAIL. THIS PLAN CHECK IS ONLY FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41385	16041-10001-29855	12067 W FOOTHILL BLVD	91342	7	213B165   562	2531006009	[T][Q]MR1-1-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.05	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.27837	-118.39887	09/01/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include adding an additional 800A service section to distribution board, reconnecting house panel to new section, and revising load calculation due to house panel. (((((((PC FOR REBUILD OF 800A SERVICE SECTION FOR FIRE DAMAGED BUILDING. REBUILD 2 SECTIONS AND RECONNECT ALL EXISTING PANELS TO SWITCHGEAR. CHECKING NEW FAULT CURRENT VALUES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41386	12041-10000-28966	12244 W BURBANK BLVD	91607	5	174B165   761	2347008032	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.01	Electrical	Electrical	Apartment			12/03/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.17197	-118.40029	REMOVE AND REPLACE DEFECTIVE FACP WITH A NEW FACP IN AN APARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41387	15041-10000-23887	700 S FLOWER ST 25TH FLOOR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI ON AN EXISTING COMMERCIAL BUILDING, TITLE 24 ON THE FIFTH FLOOR. PC FOR ENERGY AND EMERGENCY LIGHTING. TOTAL AREA = 10,812 SQ. FT.** Variance for fire alarm needs to be submitted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41388	10041-20000-01173	915 W 35TH ST Bldg D	90089	9	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM			PC Approved	06/25/2010 12:00:00 AM	ADDRESS	34.02303	-118.28676	"All revisions dated after 4/6/08 to approved plans with PCIS #09041-20000-06079.  (New Building ""D"" at USC Campus (CNTV PHASE II))."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41389	14041-10000-01020	12849 W MAGNOLIA BLVD	91607	4	171B161   508	2346023066	C2-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM			Corrections Issued	01/17/2014 12:00:00 AM	ADDRESS	34.16502	-118.41308	"(N) wall-mounted generator receptacle with new 2"" conduit for Verizon Wireless cell tower site.  Plan check per customer request."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41390	16041-10005-29628	10319 N NORRIS AVE	91331	7	204B165   115	2537004029	[Q]M1-1-CUGU, [Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM			PC Approved	03/02/2017 12:00:00 AM	ADDRESS	34.25712	-118.40313	"CHANGES TO THE APPROVED SET OF PLAN, CHANGES REFLECTED AS DELTA 3, INCLUDING CHANGE OF FEEDER SIZE, ADDITION OF  ONE 3"" CONDUIT AND REMOVEING MAIN 800A PANEL BOARD9 (3/2/2017).<<<<CHANGE TO APPROVED SET. CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO WARNING LABELS AND SERVICE ENTRANCE CONDUCTOR SIZE. PC ONLY. PERMIT ALREADY ISSUED UNDER MASTER>>>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41391	18041-10001-44474	624 S PACIFIC AVE	90731	15	015B197   463	7455005026	[Q]C2-1XL-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM			PC Approved	06/17/2019 12:00:00 AM	ADDRESS	33.73824	-118.28773	supplement to reflect the power layout . 1 exsiting 400A panel with 3 feeder , 2 feeds 60 amp panel and 1- 200A panel. no change in T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41392	16041-20001-33673	14726 W MORRISON ST	91403	4	169-5A149  72	2263028029	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM			PC Approved	10/17/2016 12:00:00 AM	ADDRESS	34.16016	-118.45406	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.5 kWac and consists of (45) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41393	10041-10000-10033	942 S TOWNE AVE	90021	9	124-5A211 251	5132003022	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	34.03442	-118.24926	Change of use from ware house to retail. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41394	10041-10000-18844	1265 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/27/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.05194	-118.22564	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41395	13041-20000-36183	22240 W RYAN RIDGE WAY	91367	3	174B101  1455	2146011044	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.17127	-118.61164	pv1 single family dwelling. 5kw ac using 33 modules. transformed inverter 3 strings	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41396	19041-20000-40062	120 N GLENROY AVE	90049	5	138B145   239	4366003015	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM			PC Approved	01/21/2020 12:00:00 AM	ADDRESS	34.07514	-118.45974	FULL PLAN CHECK FOR A NEW 600A, 120/240V SERVICE.  SCOPE OF WORK INCLUDES FOUR NEW PANELBOARDS, NEW HVAC UNITS AND 1 ELEVATOR.  NOTE: PLAN CHECK ONLY. PERMIT UNDER COMBO BUILDING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41397	17041-20000-43886	11740 W VANOWEN ST	91605	2	180B169    44	2322015010	R1-1, R3-1	South Valley	North Hollywood - Valley Village	NoHo		1232.03	Electrical	Electrical	Apartment			12/06/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.19379	-118.38943	Plan check for power and energy. Project site is a new 2-story, 11-unit apartment building. Work includes a 1,000 Amp service and a total lighting area of 12,282 sq. ft.Note: Building permit has been issued under 17010-20000-01839.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41398	18041-10000-25100	433 S SPRING ST 7TH FLOOR	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE ON THE 7TH FLOOR OF A COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 7475 SQ. FT. B#18016-10000-17809	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41399	11041-20000-04635	335 N ROCKINGHAM AVE	90049	11	132B137    66	4406002018	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Closed	04/12/2013 12:00:00 AM	ADDRESS	34.06121	-118.49125	Plan check for new roof mounted 15.2 KW photovoltacic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41400	14041-10000-24245	1601 N VINE ST	90028	13	148-5A187 301	5546009906	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Closed	04/18/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	Temporary Power for construction.  2 Elevators 800 Amp Bus switch board 3 Transformers 75 KVA. High Rise 5 below grade 8 levels above grade core  and shell. None Mathane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41401	14041-20000-32590	8748 N VALJEAN AVE	91343	12	195B137   690	2688013019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.22986	-118.48718	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system.20 345W pv modules across 4 strings (5+5+5+5).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41402	19041-10000-17691	1 S LMU DR 4TH FL	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	33.96577	-118.42406	Energy plan check for an office T.I located in the 4th floor of a commercial building. Scope includes new lighting and equipment with a total lighting  area of 6180-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41403	11041-10000-15341	758 W 23RD ST	90731	15	009B197   149	7463004018	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2972.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	33.72347	-118.2938	NEW ROOFTOP RESIDENTIAL PV SYSTEM, WITH ENPHASE MICROINVERTERS.  VARIANCE WILL BE FILED FOR MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41404	13041-20002-11066	10911 W CHALON ROAD	90077	5	141B149    68	4369028001	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.08453	-118.45569	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 4.41KW. TWO STRINGS AND A SINGLE INVERTER.  [MODULES: TRINAL SOLAR # TSM--245PC05 ||| INVERTER: POWER-ONE # AURORA PVI-3.6-OUTD-S-US] original permit under 13041-10000-11066. pc for coulded delta A changes	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41405	12041-10000-21463	20729 W BASSETT ST	91306	3	183B109   697	2137027021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2012 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.19599	-118.585	3.43 kw Roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41406	13041-10000-00551	6600 N TOPANGA CANYON BLVD # 32	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/23/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	REMODELING OF THE VICTORIA SECRET STORE AT THE TOPANGA MALLPLAN CHK IS FOR TITLE 24 AND 3EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41407	16041-20003-02117	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.0965	-118.30717	[[10/21/16 CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. CHANGING MULTIPLE FEEDERS FROM COPPER TO ALUMINUM]]][[ 10/19/16 CHANGES TO APPROVED SET. INSTALLATION OF A 600AMP BREAKER AND 2000AMP GFI BREAKER ON MAIN 5000AMP BOARD. CHANGES ARE CLOUDED]]]] TI for an existing building (offices). Plan check for power. Core and shell only.  New service 2,000A. Existing lighting to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41408	11041-10000-18850	8556 W FOOTHILL BLVD	91040	2	204B189    26	2560004026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.25957	-118.31982	RELOCATE TWO SUB-PANELS AND ADD NEW 600A SERVICE, AND 600A PANEL IN A GAS STATION.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41409	14041-20000-34755	9255 N CORBIN AVE	91324	12	198B117   150	2761001075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.23837	-118.56248	PC FOR NEW LIGHTING. LIGHTING IS FOR VANILLA SHELL OUT. PC FOR T24 ENERGY ONLY. LOW ADDITIONAL LOAD OF NEW LIGHITNG. PERMIT TO BE ISSUED UNDER THIS APPLICATION. DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 ENERGY EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41410	13041-10000-32390	10431 N GENESTA AVE	91344	12	207B133   968	2695019041	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.26047	-118.50468	PV1, Install 6 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformered inverter. Fronius IG 5100 NEG. 24 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41411	13041-10001-36219	416 N FAIRFAX AVE	90036	5	141B177  1410	5527030019	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.07873	-118.36128	CHANGES TO APPROVED: REPLACED LIGHTS WITH TRACK LIGHTING.  Plan check only. Less than 400A connected load per applicant.old description: TI IN RETAIL STORE (BoyZ Ny Store). PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41412	17041-20000-37887	13350 N GLADSTONE AVE	91342	7	225B157   369	2510001020	(T)RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			PC Info Complete	11/14/2017 12:00:00 AM	ADDRESS	34.31419	-118.43228	pv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41413	15041-10000-24057	1500 W PACIFIC COAST HWY Bldg C	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 5 unit apartment with garage, Typev VA construction. 18 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41414	14041-10000-09842	3342 N VERDUGO ROAD	90065	1	153A215   288	5456001046	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Closed	12/12/2016 12:00:00 AM	ADDRESS	34.11279	-118.23548	"PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT TO RANCHO MARKET TO REPAIR INTERIOR PARTITIONS  DUE TO FIRE DAMAGES. EQUIPMENT RATED  OVER 600AMPS.""COMPLY WITH DEPARTMENT ORDER effective date08/13/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41415	17041-10000-25469	6300 N SEPULVEDA BLVD	91411	6	177B145   116	2242010016	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.18481	-118.46591	PLAN CHECK FOR T24 ONLY - SCOPE INCLUDES REPLACING EXISTING (10) HID FIXTURES WITH NEW LED FIXTURES - TOTAL AFFECTED AREA =20250 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41416	12041-10000-00895	22627 W FRIAR ST	91367	3	180B097   680	2039021007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2012 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.18559	-118.61991	10.34kw Photovoltaic, rooftop, system for an existing single family residence.  And 225A service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41417	10041-10000-23737	1224 S BEVERWIL DR 12TH Floor	90035	5	132A167   219	4330024036	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	08/02/2011 12:00:00 AM	ADDRESS	34.0554	-118.39891	TI IN AN EXISTING COMMERCIAL AREA ON THE 12TH FLOOR.    PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41418	13041-10000-29026	1313 W SUNSET BLVD	90026	1	138A211   232	5406014006	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley		YES	1977.00	Electrical	Electrical	Apartment			10/17/2013 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.07175	-118.25041	PLAN CHECK FOR POWER AND ENERGY. NEW 3-STORY 27-UNIT APARTMENT OVER SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41419	13041-10001-27140	740 E BROOKS AVE	90291	11	111B145  1292	4239013027	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	33.99737	-118.46485	Expedcited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41420	17041-20000-03521	1215 N HIGHLAND AVE	90038	4	144B185   387	5532006028	C2-1D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.09303	-118.33886	Plan check for energy only. TI and change of use from retail art gallery to office space. New lighting (incl. emergency) and receptacles. 2,072 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41421	15041-10003-23931	11970 N SHOSHONE AVE	91344	12	216B129   204	2601051004	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM			PC Approved	07/18/2016 12:00:00 AM	ADDRESS	34.28871	-118.51716	RECHECKING FOR LOST SET OF PLANS. SYSTEM IS 3 INVERTERS TOTAL SIZE 11.6KW AC USING TOTAL OF 37 MODULES. CONNECTING TO PANEL WITH DOUBLE MAINS. 70A BACKFEED MAIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41422	18041-20000-07867	1108 N OLANCHA DR	90065	1	154-5A221 369	5475008035	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.11601	-118.21663	PV1.  Install 5.525 kW PV system.  13.5 kWh energy storage system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41423	15041-10000-12182	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	PC FOR ENERGY. RESTROOM AND LOBBY UPGRADE. TOTAL AREA 1346 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41424	11041-20000-16540	14801 W SHERMAN WAY	91405	6	183B149     9	2218021034	QR4-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	10/05/2011 12:00:00 AM	ADDRESS	34.2014	-118.45507	Remodeling offices/ ENERGYFire Life safety is existing to remainexist. permit 11041-90000-15702permit is for data only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41425	13041-10000-26316	5950 N VANALDEN AVE	91356	3	177B121   694	2156009001	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Expired	11/16/2015 12:00:00 AM	ADDRESS	34.17857	-118.54982	PV1 ROOF-MOUNTED PHOTOVOLTAIC SYSTEM WITH POWER OPTIMIZERS(OP250-LV).; SYSTEM SIZE IS 4.25KW DC. (17) MODULES: TRINA #TSM-250PA05.18(1) SOLAREDGE #SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41426	13041-10003-34279	21720 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.18733	-118.60234	ON ORIGINAL PLANS, THERE IS  AN EXISTING 2-SRORIES OFFICE BLDGING SUPPLIED FROM THE UTILITY. ELECTRICALINFORMATION SHOWN ON THE ORIGINAL PLANS FOR THE BLDG WAS INCORECT. NEW PLANS  NOW SHOW THER EXISTING BLDG WITH CORRECT ELECTRICAL RATING. CHANGES TO SERVICE CONDUCTORS WERE MADE AS THE BLDG IS SUPPLIED FROM THE MALL POWER SOURCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41427	13041-10000-33435	1200 S SANTA FE AVE 1-53	90021	14	123A217   315	5166007011	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Public Safety Only			12/02/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.02944	-118.22979	new fire warning system in a building converted to 58 ea live/work units	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41428	18041-10000-20951	14931 W CALIFA ST	91411	4	177A149   141	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.17768	-118.4586	DELTA 1 changes to the approved plans.Insttaling 23 additional devices to an existing Fire Alarm System in the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41429	18041-20003-15077	7600 N BALBOA BLVD STE 109	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	Clouded delta 8 changes only. Change to an approved set of plan, Changes include revised panel schedule loads, ratings, and calcs, addition of notes, and some outlet changes. Plan check only, permit fees covered under master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41430	19041-10000-11607	10074 W SULLY DR	91352	2	189B181    75	2403019012	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM			Reviewed by Supervisor	04/08/2019 12:00:00 AM	ADDRESS	34.218	-118.34978	PV1. NEW SOLAR SYSTEM WITH STORAGE SYSTEM BATTERY. TOTAL SYSTEM SIZE IS 11.4KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41431	16041-10000-44585	2224 N FIGUEROA ST	90065	1	142-5A219 492	5446016012	UC(CA)	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.08301	-118.2232	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALD'S RESTAURANT. SCOPE INCLUDES NEW INTERIOR AND EXTERIOR LIGHTS. TOTAL AFFECTED AREA IS 4399 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41432	14041-20001-12489	22925 W ERWIN ST	91367	3	177B097   258	2039013016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	05/17/2014 12:00:00 AM	ADDRESS	34.18296	-118.62633	Fee for expedite.****Roof mounted PV system with Optimizer, and transformerless inverters.  System size 7.65KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41433	14041-20000-24105	4564 W DUNDEE DR	90027	4	153B197    54	5588031013	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.11704	-118.28777	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.6kW.(1) ABB UNO-7.6-TL-OUTD-S-US-A transformerless inverter(26) SolarWorld SW315XL MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41434	19041-10000-52355	5750 W WILSHIRE BLVD 3rd Floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Info Complete	06/24/2020 12:00:00 AM	ADDRESS	34.06227	-118.3542	Interior T.I. to Office area on the 3rd Floor. Plan Check for Power & Energy. Added Load > 400Amp. Affected area: 83,468 SFT. Building Permit: 19016-100000-40170	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41435	16041-20000-36923	11831 RICASOLI WAY	91326	12	216B109    71	2701078017	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	PIN	34.28766393	-118.58497699	Plan check for a PV1 roof-mounted PV system. System size is 7.3 kWac and consists of (29) modules, (29) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41436	16041-10000-28514	5630 W SANTA MONICA BLVD	90038	13	144B193   768	5536018021	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.09062	-118.3125	RENOVATION TO HOTEL. WORK DONE ON FLOORS 2 AND 3. PC FOR T24 ENERGY ONLY. CHECKING COMMON AREA T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41437	19041-20000-49788	21700 W OXNARD ST #1050	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.17901	-118.60179	Power and lighting for (E) commercial highrise tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41438	19041-10001-30947	5966 N TOPEKA DR	91356	3	177B121   813	2156018044	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.1789	-118.54601	NEW ROOF MOUNTED 15.4KW PV SYSTEM WITH 49 PV PANELS AND OPTIMIZER AND ONE CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41439	14041-20000-05128	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.24138	-118.60168	existing manufacturing. permit for equipment rated greater than 400A. New Heller 1810 machine plus small additional loads	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41440	14041-20001-00626	4432 N BROOKFORD AVE	91364	3	165B097   202	2078003018	RS-1	South Valley		Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.15069	-118.62568	((EXPEDITE FEES))PV1 7.0KWAC 3 STRINGS 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41441	18041-10000-41210	4600 W BRAZIL ST	90039	13	165B201   241	5593011050	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Issued	10/29/2018 12:00:00 AM	ADDRESS	34.14673	-118.27548	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41442	19041-10000-46139	333 S HOPE ST 13th Flr	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	04/21/2021 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 17938 SFQT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41443	14041-10001-29516	6614 W HOLLYWOOD BLVD	90028	13	148-5A185 130	5547015013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	04/03/2015 12:00:00 AM	ADDRESS	34.10141	-118.33371	Changes to approved set.  Redesign of lighting on first floor.(((Change of use to joint living and work quarters. Energy plan check for 1st floor recording studio)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41444	14041-20000-11808	19801 W NORDHOFF PL	91311	12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Issued	05/14/2014 12:00:00 AM	ADDRESS	34.23568	-118.56464	"PLAN CHECK FOR EXISTING COMMERCIAL WAREHOUSE. T-24 AND EMERGENCY LIGHTING ONLY IN THE FIRST AND SECOND FLOOR.""COMPLY WITH DEPARTMENT ORDER effective date11/13/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41445	12041-20000-14826	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	33.97704	-118.40702	Install new 3000 ampere service equipment, feeders to new buildings, and site lighting for industrial park.  Plan check to ask for all missing  93.0207 details.  Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41446	18041-10000-31486	7600 W MANCHESTER AVE BUILDING 2-1ST 2ND FL	90293	11	096B157   650	4119001009	C1.5-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	33.95947	-118.43088	PC FOR ENERGY ONLY, INTERIOR REMODEL OF TWO EXISTING TENANT LOUNGE AREAS ON 1ST AND 2ND FLOOR OF BUILDING #2; SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1328.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41447	17041-20001-33666	5020 W SANTA MONICA BLVD	90029	13	144B197  1452	5538002***	C2-1D, R3-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Apartment			01/08/2018 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.09059	-118.29871	"1/8/2018changes to an approved set of plans.  changes include additional section to distribution board ""DBA"" and ""DBB"". changes noted delta 1.  plan check for power only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41448	19041-20000-29082	6617 N FALLBROOK AVE	91307	12	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.19033	-118.62372	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41449	10041-20000-06806	4644 S LINCOLN BLVD #428	90292	11	105B153   132	4224014024	[Q]C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	08/19/2010 12:00:00 AM	ADDRESS	33.98217	-118.44043	PLAN CHECK POWER AND ENERGY.  T. I. FOR DENTAL OFFICE (SUITE #428).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41450	15041-20000-13679	18851-18853 W VENTURA BLVD	91356	3	174B121   443	2160002028	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM			PC Approved	05/18/2015 12:00:00 AM	ADDRESS	34.17228	-118.54425	T.I. to existing commercial building (Sprint). Plan check for energy only. New lighting in retail space (fixture L50 only). Emergency lighting is existing to remain. Total Sqft. 1,539.Permit pulled under permit #15041-70000-14431.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41451	14041-10000-31785	22056 W RUNNYMEDE ST	91303	3	186B101   556	2023004001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.20542	-118.60795	Installation of new roof mounted solar PV array.  Total system size = 7.2 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41452	13041-20000-12104	5444 N YOLANDA AVE	91356	3	174B121   791	2161015001	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			Reviewed by Supervisor	06/12/2013 12:00:00 AM	ADDRESS	34.17002	-118.54025	FULL PLAN CHECK FOR FIRST TIME TENANT HAIR SALON. TOTAL CONNECTED LOAD EXCEEDS 400A. 6400 SQRFT. APPLICATION CLOSED. REFER TO NEW PERMIT AND T24 ENERGY ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41453	14041-10000-02408	6813 N TUJUNGA AVE	91605	2	183B173   250	2320003008	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.1945	-118.3792	Remove HID light fixtures and replace with new fluorescent fixtures in a storage space.  Title 24 plan check for fixture one-to-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41454	16041-10002-26342	10400 S AVIATION BLVD	90045	11	090B173   318	4129034001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	33.94154	-118.37829	"CHANGES TO AN APPROVED SET OF PLANS UNDER DELTA 21 AND DELTA 22.CHANGES  INCLUDE 1.REROUTING OF ""MSH"" FROM LINE SIDE CONNECTION TO LOAD SIDE FEED FROM ""MS"".2.ADDING ISOLATION TRANSFORMER BETWEEN ""MSH"" AND ""MCCH"" AND REVISION TO AIC RATINGS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41455	14041-20001-32506	11777 W SAN VICENTE BLVD 880	90049	11	129B145    59	4401017026	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			12/08/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.05331	-118.46832	12.8.2014 - Plan check for energy/Title-24 only. Permit already pulled under permit #14041-30000-32506.TI to office on 8th floor of high rise office building. 1,159sqft.[TENANT IMPROVEMENT. RELOCATE DUPLEX, SWITCHES, POWER & LIGHTS.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41456	19041-10000-01633	3785 W WILSHIRE BLVD SUITE 104	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			Reviewed by Supervisor	02/08/2019 12:00:00 AM	ADDRESS	34.06187	-118.30858	PER APPLICANT REQUEST: FULL PLAN CHECK FOR A CHANGE OF USE FROM RESTAURANT TO RETAIL/MARKET, 7-ELEVEN  CONVENIENCE RETAIL STORE.  SCOPE INCLUDE NEW LOAD AND LIGHTING .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41457	17041-10000-06470	19800 S VERMONT AVE	90502	15	057B197    54	7351033039	[Q]C4-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	33.85122	-118.29031	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012PV2 COMMERCIAL CARPORT PV SYSTEM. TOTAL OF 963 MODULES AND 11 CENTRAL INVERTERS. CONNECTING TO EXISTING BUILDING MAIN SWITCHGEAR. SYSTEM SIZE 313KW DC/ 273KW ACSYSTEM USES POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41458	11041-10000-01708	1220 W 28TH ST	90007	8	120B197    13	5055028034	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			01/28/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	ADDRESS	34.02924	-118.28715	New service, panel board, and branch circuits for existing 23 units appartment BLDG. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41459	13041-10000-15022	580 S MATEO ST	90013	14	126A217    82	5164006004	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.03937	-118.2327	Restaurant tenant improvement.  New service and electrical distribution system.  A2 occupancy with 299 occupant load as per occupant.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41460	12041-20000-08888	6430 W SUNSET BLVD STE. 1205-N.W. CNR	90028	13	147A187   153	5546014047	C4-2, D	Central	Hollywood			1908.02	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.09782	-118.32979	ENERGY P/CHECK FOR OFFICE SPACE (TENANT IMPROVEMENT @ SUITE 1205. 800 SQ. FT. NEW CEILING GRID. NON-STRUCTURAL PARTITION.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41461	11041-20000-01276	6351 N OWENSMOUTH AVE #203	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Expired	02/19/2013 12:00:00 AM	ADDRESS	34.18594	-118.60181	PLAN CHECK T24ENERGY (GENERAL/EMERGENCY) LIGHTING FOR OFFICE TI SUITE #203. REPLACE LIGHTING FIXTURES ON EXISTING CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41462	16041-20000-31193	5071 N SHIRLEY AVE	91356	3	171B117   404	2175031001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.16334	-118.55727	PV1EXPASION TO AN EXISTING PV SYSTEM.INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED TO MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41463	13041-10001-26304	6431 N LONGRIDGE AVE	91401	2	180B157   886	2326025003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.18746	-118.4206	][][][EXPEDITED PER APPLICANT REQUEST [][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH mAIN; WORK DONE ON A NON STANDARD PLAN. SYSTEM SIZE IS 6.25KW DC WITH (25) MODULES: TRINA #TSM-250PA05.18(1) POWER-ONE #AURORA PVI-6000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41464	10041-20000-09642	8181 N SUNLAND BLVD	91352	6	192B173   817	2409001015	[Q]C2-1L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM			Corrections Issued	06/04/2010 12:00:00 AM	ADDRESS	34.2189	-118.36943	MARKET TI. LIGHTING AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41465	13041-20000-30873	13025 W HARTSOOK ST	91423	4	171B161   635	2358031011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.16408	-118.41672	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41466	16041-20000-21638	15026 W SCHOENBORN ST	91343	6	192B145   341	2653024010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.22261	-118.46028	PV1.  Install 6.75 kW roof mounted PV system.  Central inverter standard plan.  (27) modules with (1) 6 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41467	19041-20000-28703	13161 W VICTORY BLVD	91401	2	180B157  1190	2326021019	(Q)RAS3-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Re-Activate Permit	05/27/2020 12:00:00 AM	ADDRESS	34.18684	-118.41991	new sfd 600 amp service.  plan chech for power only.  permit fees paid under building combo permit 16010-10000-02871	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41468	16041-10000-33225	754 E WASHINGTON BLVD	90292	11	105B149   187	4229016017	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	33.98739	-118.45315	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM IS 6.0KWac.(29)MODULES-SOLARCITY #SC265(1)INVERTER-ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41469	17041-10000-17951	541 S SPRING ST UNIT 131	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.04657	-118.2507	PC FOR TI FOR A RESTAURANT FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 459 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND NEW RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41470	17041-20001-22227	1672 N CLEAR VIEW DR	90210	5	147B153    54	4356005013	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM			PC Approved	09/06/2019 12:00:00 AM	ADDRESS	34.10214	-118.43445	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED DELTA 2 ONLY. CHANGES MADE TO SINGLE LINE, ADDITION OF SUB PANELS AND EQUIPMENT, CHANGES MADE TO LOAD CALC, SCOPE OF WORK, FLOOR PLAN, AND SITE PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41471	19041-20000-47728	13263 N WHEELER AVE UNIT 11	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41472	12041-10000-11470	23239 W CASS AVE	91364	3	165B097    80	2076012028	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.15167	-118.62109	NEW 13 KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41473	19041-20001-07277	3525 W 8TH ST	90005	10	132B193   572	5093011013	(T)(Q)C2-2D	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	ADDRESS	34.05782	-118.30714	5/20/2019changes to an approved set of plans.  changes to update the single line diagram to reflect field conditions.this is plan check only.  ((((temp power for construction site 1000 amp serive.  plan check for power.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41474	19041-20000-21567	1342 N ORANGE DR	90028	4	147B181  1033	5548023030	RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.09557	-118.34142	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING BACKYARD PATIO FEEDING THE MAIN EXISTING HOUSE. SYSTEM SIZE IS 4.2KW DC/7KW AC. SCOPE OF WORK INCLUDES (14) SILFAB PV MODULES WITH (14) LEAD SOLAR MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41475	16041-20000-42719	669 W WEST 34TH ST 2nd Floor	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.02212	-118.28244	Plan check for energy only. TI to copy room and conference room on 2nd floor. New lighting (incl. emergency) and receptacles. 601sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41476	16041-20002-15692	12602 W VENTURA BLVD	91604	2	162B161   146	2384022024	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM			PC Approved	06/17/2016 12:00:00 AM	ADDRESS	34.14333	-118.40789	[[[6/17/16  CHANGES TO APPROVED SET. TO UPDATE T24 PLANS PER INSPECTORS REQUEST ]]]Revision to approved set, this is PC only, permit will be issued under master E#.Changes on floor plan and light fixtures, adding controlled receptacles in the private office and conference room. Total area remain the same.<<CHANGE OF USE  OF A PORTION OF AN EXISTING RETAIL BUILDING TO A PHARMACY AND AN INTERIOR TI. USE (E) CIRCUITS, PC FOR T-24 (lighting only, no new receptacles). TOTAL AREA: 2,280 SQ.FT>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41477	15041-20000-16462	7801 N HAYVENHURST AVE	91406	6	189B137   125	2205009094	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			Corrections Issued	05/29/2015 12:00:00 AM	ADDRESS	34.21242	-118.49404	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41478	10041-20000-22380	1916 S SAN PEDRO ST	90011	9	121-5A209 131	5131006028	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.02715	-118.25753	PLAM CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT - FOOD STORE. NEW LOAD DOES NOT EXCEED 400AMP. PERMIT FOR NEW EQUIPMENT, NEW CKTS, AND MISC PERMIT FOR LOW VOLTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41479	13041-20001-09967	9747 N DANUBE AVE PV 1	91343	12	201B141   315	2671003017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Expired	07/21/2015 12:00:00 AM	ADDRESS	34.24781	-118.47528	(((SUPP PC AND PERMIT FOR CHANGES TO ORIGINAL PLANS. CHANGE IN INVERTER REQUIRES PC AND PERMIT ADDITION FOR CIRCUIT AND 2 PANELS.)))INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE 5.145 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41480	14041-20001-02386	5444 N YOLANDA AVE	91356	3	174B121   791	2161015001	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.17002	-118.54025	BEAUTY SALON. PC FOR T24 ENERGY ONLY. PER APPLICANT EXISTING 600A SERVICE. NEW LIGHTING. LOAD LESS THAN 400A ((((SUPPLEMENTAL APPLICARTION FOR FULL PLAN CHECK FOR POWER. T24 ENERGY ALREADY APPROVED UNDER ORIGINAL APPLICATION 14041-20000-02386. PERMIT TO BE ISSUED UNDER THIS APPLICATION FOR REMAINING BALANCE OF ITEMS. )))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41481	09041-10002-16635	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.07417	-118.26931	DELTA 2 REVISIONS((((TI - Core shell.  Highrise.  Permit is for new service, new boards, new panels, refeed existing panels, new equipment, all emergency lighting and branch circuits are existing to remain.  The emergency distribution is existing and is intercepted by new shunt controlled diconnects.  Approved tenant submittals for 7th-15th floors cover all equipment and circuits on those floors.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41482	15041-20000-32290	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.24253	-118.57768	Plan check for energy only. TI to office spaces. New lighting (incl. emergency) and receptacles. 6,832sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41483	15041-10000-05354	1515 W WILSHIRE BLVD	90017	1	132A205   253	5142027037	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			02/24/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.05498	-118.2688	PC FOR NEW FA SYSTEM. 552 FA DEVICES AND ONE CONTROL PANEL AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41484	18041-10000-26724	10408 N BALBOA BLVD	91344	12	204B133    17	2684012038	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.25952	-118.50211	*Zero permit fee per SB-1222/ AB-1414*Plan check for a 50KW AC/ 55.38 kW DC/ 49.079 kW AC CEC, PV2 system installed on a carport with (156) modules and (1) 50KW inverter interconnecting through the subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41485	11041-10000-15310	8724 W FOOTHILL BLVD	91040	2	207B189  1064	2547027002	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1033.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.2602	-118.32375	T.I.  Existing 7-11.  Replacing 36 light fixtures, using the existing branch circuits, in the retail area only.  Plan check is energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41486	19041-20000-15114	1833 S MESA ST	90731	15	012B201   783	7456029034		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	33.72727	-118.28601	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41487	14041-20000-28047	11835 W OLYMPIC BLVD 5th Floor	90025	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	PIN	34.03318579	-118.45141815	TI to (E) 18,000 s.f. commercial office space.  Newly connected load in excess of 400A.  (N) optional standby generator for furniture systems.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41488	16041-10002-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	05-02-2017 Plan check to an approved set of plan. Paln check on E-1.01N. PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41489	12041-10000-17396	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	11/02/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVEMENT IN OFFICES ON THE 3RD FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41490	15041-10000-38788	223 W 52ND PL	90037	9	108B201   231	5110029019	R2-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	33.99479	-118.27702	PV1, ROOF MOUNTED SOLAR SYSTEM. (32) MODULES AND (1) INVERTER. TOTAL SIZE: 7.6KW-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41491	13041-10000-06078	2131 N HILLHURST AVE	90027	4	150B197    76	5590003040	[Q]C4-1	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.11109	-118.28759	NEW FIRE ALARM SYSTEM FOR CHURCH (BASEMENT, GROUND FLOOR, AND SECOND FLOOR). 1 NEW FIRE ALARM PANEL AND 86 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41492	15041-10001-06089	722 S BIXEL ST 1-316	90017	1	130-5A207 630	5143004011	CW	Central	Westlake	Downtown Los Angeles		2093.00	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.05004	-118.26445	Expedite per customer request(((PV2 225KW roof-mounted system with (1) Solectria Smartgrid-225, (10) combiner boxes,  and (828) Inotech Solar-260w  modules interconnecting  the main building panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41493	17041-10000-11976	2016 E BAY ST	90021	14	123A217   199	5166011021	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.03132	-118.2316	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 40950 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41494	13041-20000-35736	5430 N LOUISE AVE	91316	5	174B133   787	2258001061	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Expired	01/25/2016 12:00:00 AM	ADDRESS	34.16987	-118.50962	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.75KW. 19 MODULES AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41495	18041-10000-40703	7400 N COLDWATER CANYON AVE	91605	2	186B161   521	2324001011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	02/06/2019 12:00:00 AM		Issued	02/06/2019 12:00:00 AM	ADDRESS	34.20498	-118.41362	NEW COMMERCIAL ROOFTOP SOLAR SYSTEM CONSIST OF  68 MODULES (AXITEC AC 325P),  68 OPTIMIZERS (SOLAR EDGE P-400) AND 2 CENTRAL-INVERTERS (SOLAR EDGE SE 10000A-US). SCOPE INCLUDES A NEW 200A PANEL(PV-2) SYSTEM SIZE IS 22.1KWdc and 20KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41496	16041-20000-29612	1680 N VINE ST Suite 600	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			PC Approved	08/19/2016 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for Title 24 only. Project site is an existing suite within a commercial building. Project scope is a tenant improvement. Total lighting area = 3,030 sq. ft.Note: Applicant has provided an Modification of Building Ordinaces Form that allows 90-minute battery back-up unit equipment to be used as emergency egress illumination. Modification was approved by Patrick Gilbert on 08-26-2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41497	18041-10000-42877	2111 N GRIFFIN AVE	90031	1	136-5A223  28	5204018006	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	10/12/2020 12:00:00 AM	ADDRESS	34.06975	-118.21183	INSTALLATION OF A NEW FA SYSTEM FOR A HIGH SCHOOL. WITH 1 FACP AND 150 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41498	14041-10000-32479	1875 S CENTURY PARK EAST	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.06115	-118.41457	Title 24 plan check only Total area: 1279 sq ft for commercial	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41499	12041-10000-15877	14006 W RIVERSIDE DR FC8	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	09/04/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	TENENT IMPROVEMENT WITHIN AN (E) FOOD COURT TAKE-OUT RESTAURANT (SPACE #FC8) WITHIN AN (E) MALL. NO CHANGE IN AREA, USE, OCCUPANCE is 4, AND Load is less than 400A.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41500	12041-20000-29257	315 W 9TH ST 904	90014	9	127-5A209 141	5144018049	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	PIN	34.04341508	-118.25728547	Plan check for energy and emergency lighting. Commercial high-rise. Suite 904. 2950 sqft.CRA clearance approved in building application already. (12016-10000-23279)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41501	10041-20000-02377	12035 E WATERFRONT DR 3RD FLOOR	90094	11	105B161  1201	4211011029	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	02/18/2010 12:00:00 AM		Issued	02/18/2010 12:00:00 AM	PIN	33.98250733	-118.40585209	T.I WORK 3RD FLOOR IN HIGH RISE BUILDING DOING LIGHTING AND POWER. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41502	16041-10004-40602	11120 W CHANDLER BLVD Build. 2	91601	2	171B173   257	2350015036	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.168	-118.37317	PC FOR REVISIONS TO APPROVED SET FEEDER SCHEDULE WAS UPDATED TO INDICATE CHANGES TO THE SIZE OF FEEDERS AND EGC TO MEET VOLTAGE REQUIREMENTS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41503	16041-10002-25050	1426 S HAYWORTH AVE	90035	10	129B173   575	5068017016	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			05/31/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.05069	-118.36762	Change to approved set by modifying the floor plan and adding an additional EV panel.(((PLAN CHECK FOR POWER AND ENERGY.  NEW 3-STORY, 8-UNIT APARTMENT BUILDING, OVER ONE LEVEL SUBTERANEAN PARKING. 800 A  3PH-4W SERVICE. TOTAL AREA 7,894 SQ.FT. LOCATED ON METHANE ZONE.B# 14010-10000-04170)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41504	16041-10001-41939	5422 N LEMONA AVE	91411	4	172-5A147  33	2250014023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.16913	-118.45944	Note: fees are $0 due to senate bill 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.935KWdc / 7.36KWac.(23)AC MODULES-SUNPOWER SPR-X21-345-C-ACNote: Permit for rest of solar equipment is paid under PCIS#16041-90000-41940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41505	16041-10000-45417	1122 W WASHINGTON BLVD	90015	1	126A201   241	5135014042	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.03877	-118.28233	Plan check for power and Title 24.  T.I. to 4 story medical office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41506	16041-20000-18173	601 W 5TH ST #630	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Title 24 only in existing space T.I. Total area: 2,313 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41507	17041-30000-31009	444 S FLOWER ST STE 1550	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Info Complete	08/29/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only in  exiting space high-rise building T.I. office space. Total area: 7760 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41508	18041-20000-09570	1999 S AVENUE OF THE STARS FLOOR 27	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. 10144 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41509	16041-10001-34365	1805 N WILCOX AVE	90028	13	150A187   341	5547006014	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Apartment			12/09/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.10406	-118.33134	PC FOR REMODEL OF APARTMENT AND DWELLING UNIT UPGRADES. PROVIDING NEW AIR CONDITIONING UNITS AND UPGRADING UNIT PANELS. UPGRADING MAIN SERVICE TO 800A. PC FOR POWER SYSTEMS ONLY. NO NEW LIGHTING IN COMMONS UNDER THIS SCOPE. PERMIT FOR PANELS AND CIRCUITS ALREADY ISSUED. THIS PERMIT WILL COVER THE NEW SERVICE AND 600A RESIDENTIAL SECTIONS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41510	11041-20000-09930	11400 W OLYMPIC BLVD #1400	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	06/21/2011 12:00:00 AM	ADDRESS	34.03666	-118.44346	PLAN CHECK T24 ENERGY LIGHTING/EMERGENCY FOR TENANT IMPROVEMENT SUITE #1400. PERMIT FOR NEW CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41511	18041-20003-35025	5232 E BALTIMORE ST	90042	1	154-5A225 270	5478017007	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.11776	-118.20222	Changes to an approved set of plan, Changes include revised conductor size and update as built drawing. Changes apply to clouded area only. Plan check only. Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41512	10041-10000-12673	8408 W 3RD ST	90048	5	138B173   821	5511032045	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM			PC Info Complete	07/01/2010 12:00:00 AM	ADDRESS	34.07292	-118.37356	REMODEL AN EXISTING RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41513	14041-20001-09759	4647 N CANOGA AVE	91364	3	168B105   932	2190016004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	ADDRESS	34.15278	-118.59611	Expedited plan check per applicant request.  (((PV1.  Install 5 kW DC roof-mounted PV system, interconnect with main service panel.  (20) modules.  Microinverter nonstandard plan: Enphase M215-60-2LL.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41514	12041-20000-30046	8850 N TAMPA AVE 1-7	91324	12	195B117   410	2784003072	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.23108	-118.55333	Change to lighting in an existing office space.  Load is less than 400 amps per applicant.   PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41515	13041-10000-00375	950-952 E 12TH ST	90021	9	123A211   200	5132013030	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.03131	-118.24832	new building for retail use. 6944 sq ft. t24 and power plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41516	16041-10000-12158	4636 N LONGRIDGE AVE	91423	4	168B157   636	2360025024	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.15505	-118.42128	PERTMIT IS $0 DUE TO SENATE BILL 1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KWac INTERCONNECTED WITH MSP.(50) MODULES-CANADIAN SOLAR CS6P-265P(1) INVERTERS-SOLAREDGE 11.4KW	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41517	18041-20000-23741	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.21302	-118.45859	ti to an existing commecial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41518	18041-10000-28600	5901 W CENTURY BLVD 750	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Issued	07/30/2018 12:00:00 AM	ADDRESS	33.94572	-118.38685	Energy plan check for an office T.I located on the 7th floor of a high rise building. Scope includes new lighting and equipment with a total area of 5,038 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41519	17041-10000-17173	877 W 7TH ST	90731	15	015B197   536	7454001001	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	33.73777	-118.29625	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 17,415 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41520	12041-20000-22749	617 N LA BREA AVE	90036	5	141B181   781	5525016004	C4-1VL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM			PC Approved	10/05/2012 12:00:00 AM	ADDRESS	34.08241	-118.34424	Change to lighting and receptacles to an existing retail space.  Load is less than 200 amps.  Plan check only for Energy, No emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41521	15041-20000-35054	3524 N BEVERLY GLEN BLVD	91423	4	159B149   206	2274009012	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.1342	-118.44978	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 6KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41522	17041-10001-34321	8803 S FIGUEROA ST	90003	8	096A201   156	6038006037	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	ADDRESS	33.95717	-118.28299	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41523	16041-10000-23169	7433 N ALABAMA AVE	91303	3	186B105   483	2111007007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.20558	-118.59916	PV1. AN ADDITION TO AN EXISTING SOLAR SYSTEM FOR A SINGLE FAMILY DWELLING. ADDING 3.0KWac TO AN EXISTING 3.8KWAC SYSTEM. TOTAL SYSTEM WITH NEW AND EXISTING IS 6.8KWac. (8)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB# PVI-3.0-OUTD-S-US-A	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41524	18041-20000-24241	1000 N NORTH MAIN ST	90012	1	135A217   164	5409009010	UC(CA)	Central	Central City North			2060.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	05/14/2020 12:00:00 AM		Permit Finaled	08/05/2021 12:00:00 AM	ADDRESS	34.06285	-118.23379	Plan check for power and energy. Work includes a 1,000 Amp service and a total lighting of 209,500 sq. ft.Note: Building application has been generated under 17010-10000-04084.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41525	15041-20000-15250	4533 N LAUREL CANYON BLVD Classroom-18 & 26	91607	2	165B165    30	2364005021	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.15303	-118.39667	Plan check for Title 24 only. Project site is two classrooms with an existing school. Project scope is a tenant improvement. Total lighting area = 1,702 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41526	15041-10000-14972	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR ENERGY ONLY. TI FOR MACY'S STORE.TOTAL AREA 16953 SQ FT(CONDITIONED AREA).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41527	13041-10000-19810	5671 N OAKDALE AVE	91367	3	174B113   227	2153017015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Expired	09/10/2015 12:00:00 AM	ADDRESS	34.17426	-118.56583	PV1 6.37KW 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: powerone PVI-6000-OUTD-US-Z] [( 26) MOD: TRINA {TSM-245PC05.18}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41528	18041-20000-07673	10244 N NORRIS AVE	91331	7	204B165   133	2537003045	[Q]M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.25621	-118.40174	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the replacement of existing fixtures with LED fixtures. Total lighting area = 32,300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41529	15041-20001-26148	19113 W LUDLOW ST	91326	12	210B121   489	2718009010	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM			PC Approved	08/29/2015 12:00:00 AM	ADDRESS	34.27033	-118.54914	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41530	11041-10005-06422	8500 W BURTON WAY	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	DELTA 21 CHANGES TO THE APPROVED PLANS. CHANGE THE T24 AND ADDITION OF CKTs TO THE PANELS.     ((((((((((New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41531	14041-20001-13377	20757 W KINGSBURY ST	91311	12	207B109   389	2706011031	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.26373	-118.58634	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.5KW INTERCONNECTED WITH MAIN PANEL.(30) MODULES RENESOLA 250W WITH POWER OPTIMIZERS(2) TRANSFORMAERLESS INVERTERS SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41532	15041-20001-08242	17621 W SUPERIOR ST	91325	12	201B129   252	2755010026	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM	ADDRESS	34.24686	-118.51875	Plan check for a PV1 roof-mounted PV system. System size is 12.8 kWac and consists of (64) modules, (3) inverters, and (1) 125-amp rated load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41533	18041-20000-25831	7024 1/2 GREELEY ST	91042	7	202-5A201 403	2568016029	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Issued	07/11/2018 12:00:00 AM	PIN	34.24860068	-118.28415089	Plan check for a PV1 roof-mounted PV system. System size is 3.05 kWdc and consists of (1) 3 kWac rated inverter, (10) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41534	16041-20000-40307	14731 W BURBANK BLVD	91411	4	174B149   829	2244018018	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Apartment			11/15/2016 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	03/24/2023 12:00:00 AM	ADDRESS	34.1723	-118.45437	Plan check for power and energy. Project site is a new 3-story, 38-unit apartment building: 2 levels of residential over 1 level of parking garage.Note: Building application has been generated under 16010-10000-02286	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41535	11041-10000-27134	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			12/20/2011 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.01925	-118.37654	Two new services & 4 distribution board for an existing commercial bldg. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41536	13041-20000-03841	16620 W STAGG ST	91406	6	189B137   110	2205009079	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.21302	-118.49616	Plan check for energy only of a warehouse bathroom. WHSE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41537	14041-10000-35356	6816 N INDEPENDENCE AVE	91303	3	183B109   872	2138029004	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1349.03	Electrical	Electrical	Public Safety Only			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.19428	-118.59046	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING AT 18-UNITS APT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41538	11041-10000-05924	15249 W VICTORY BLVD	91411	6	180B145   596	2235001022	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Finaled	11/21/2011 12:00:00 AM	ADDRESS	34.18686	-118.4657	New Chase bank. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41539	17041-30001-01872	2134 W SUNSET BLVD unit D	90026	13	139-5A207 120	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	34.07723	-118.26485	Recheck due to lost set of plan. Permit to be pulled under master application.Title 24 plan check.  Change of use from restaurant to take-out restaurant.  New lighting and kitchen equipment fed from existing subpanels.  Total area = 532 sq. ft.Building permit number 17016-30000-01081	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41540	11041-10000-07038	7800 N HASKELL AVE	91406	6	189B141   209	2206001020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.21241	-118.47476	TI IN AN EXISTING OFFICE BUILDING.   REPLACING THE EXISTING 1600AMP SWITCHBOARD , INSTALL NEW TRANSFORMER, PANELS & CIRCUITS. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41541	11041-20000-06919	5700 W WILSHIRE BLVD 5th floor	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	05/13/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.06218	-118.35303	T.I. to a high rise building.  Install general/emergency lighting in office area on 5th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41542	17041-10001-01309	1331 N CAHUENGA BLVD	90028	13	147A187   323	5546017014	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	34.09556	-118.32924	Changes to an approved set of plans. All changes are clouded under delta 12. Changes include reducing conductor sizes for two feeders on the single line diagram.Note: Permit is paid under PCIS#17041-10000-01309	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41543	18041-10000-46439	300 WORLD WAY Concourse-Head-House	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	08/17/2022 12:00:00 AM	ADDRESS	33.94502	-118.40714	LAX Terminal 3 Renovation (Phase I). Concourse and Head House.Building Permit: 18016-10000-19512	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41544	13041-10000-29498	12867 W HAMMOCK LANE	90094	11	102B157   397	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	33.9749	-118.41979	PV1, Installing roof-mounted solar array, interconnet with main panel. System size: 4 KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41545	13041-10000-34451	1751 W 36TH PL	90018	8	120B193  1339	5041014037	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.02209	-118.31047	PV1, Install a 2.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41546	12041-10001-17627	7055 W SUNSET BLVD	90028	13	147B181   581	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	ADDRESS	34.09813	-118.34337	((((((((((((( 10-12-12 M.Z CHANGES MADE TO PREVIOUSLY APPROVED SET))))))))))))))))))))))))))))CREATE OPENING AND COMBINED RETAIL AND RESTAURANT TO CHANGE OF USE TO RESTURANT.  OCCUPANCY LOAD IS 79 AND LOAD IS 320A PER APPLICANT.  PLAN CHECK ONLY FOR ENERGY, WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41547	14041-10000-09987	618 S RAMPART BLVD	90057	1	133-5A201  30	5141009023	C2-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.06174	-118.28164	Plan check for power and energy for new 7-11 on existing switchboard.  Eqipment rated for 600 amps or more.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41548	13041-20000-14202	20750 W VENTURA BLVD SUITE 155-160	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.16638	-118.58506	RENOVATION OF OFFICE SPACE. BEAUTY SALON, TRAINING, MARKETING, BUISNESS. PC FOR T24 ENERGY ONLY. TOTAL AREA 6305 SQ FT. WORK DONE IN 155 AND 160. EMERGENCY LIGHITNG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41549	15041-10002-25712	20120 W VIA MEDICI	91326	12	219A115   350	2701041009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.29497	-118.57171	PV1, CHANGES TO AN APPROVE SET. NOTE CHANGES ON DELTA 1. CHANGES INCLUDE THE REVISION OF LOAD CALCULATIONS.***PERMIT FEE IS $0 PER STATE SENATE BILL #1222(PV 1 ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY HOME. (2) INVERTERS 13.6KW INTERCONNECTED WITH THE MAIN SERVICE PANEL, (56) MODULES.***PERMIT FEE IS $0 PER STATE SENATE BILL #1222)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41550	14041-20000-05506	1416 S ABBOT KINNEY BLVD	90291	11	108B145  1438	4238005041	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM			PC Approved	02/28/2014 12:00:00 AM	ADDRESS	33.99037	-118.46548	T24 FOR EXISTING BEAUTY SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41551	14041-20000-29234	21666 W YUCATAN AVE	91364	3	168B105   606	2171005008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.15634	-118.59985	PV1Using standard plan. Install roof-mounted solar array on SFD. Interconnect with MSP. System size 7.6kW. Two ungrounded inverters. Each has a string of 17 modules for a total of 34 255W pv modules. Using 300W power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41552	13041-10001-03297	303 S PACIFIC AVE	90731	15	018B197  1575	7451018900	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Apartment			01/15/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	33.7413	-118.28819	plan check only.CLOUDED CHANGES TO SLD, NEW CONDUIT SIZE AND NEW FEEDER SIZE, CHANGE OF CONDUIT AND FEEDERS DUE TO CALCULATIONS THAT SUCH SIZES ARE NOT NEDED>>>>>>>>> NEW CONSTRUCTION OF 49 UNIT APARTMENT COMPLEX. PC FOR POWER AND ENERGY. TOTAL AREA OF 59267 SQ FT. APARTMENT ONLY, NON MIX USE. NOT methane. will pull permit for conduit only 13041-10000-27091 (conduit only variance filed on 9/30/13) tomorrow.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41553	15041-20000-42198	2511 W 3RD ST	90057	13	135A203    96	5155033018	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.02	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.06525	-118.27685	TI TO AN EXISTING BUILDING, DIALYSIS CLINIC OSHPD-3. PC FOR POWER. I2.1 OCCUPANCY EXEMPT FROM ENERGY. PERMIT 1 OF 2 OF THE SAME PROJECT.  FOR CONTRACTOR 1, SCOPE INCLUDES MAIN SERVICE UPGRADE AND EXISTING SUBPANEL REPLACEMENT AND RECONNECTING EXISTING LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41554	13041-10001-34434	18624 W KIPTON PL	91356	3	165B125    74	2177016007	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.15199	-118.5378	Expedited RSES plan check per applicant request.{{PV1, Install a 12.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) inverter(s)[SOLAREDGE # SE6000A-US] and (49) modules[HANWHA # HSL60P6-PB-4-250TW] for 1-story house. With power optimizer}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41555	14041-20000-17414	7605 N LOUISE AVE	91406	12	186B133   190	2202009009	C2-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	PIN	34.20870027	-118.51021237	NEW 23 UNIT, 3 STORY APT. BLDG OVER 1ST FLOOR PRIVATE PKG. GARAGE.  1200A 120V/208Y SERVICE.VARIANCE TO SEPARATE FIRE ALARM PLANS FILED 06/27/2014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41556	17041-20000-06921	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			Reviewed by Supervisor	03/28/2017 12:00:00 AM	ADDRESS	34.07666	-118.3805	Plan check for Title 24 only. Project site is an existing parking garage. Project scope is parking garage lighting. Total lighting area = 799,998 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41557	13041-10000-03518	2219 W NORWALK AVE	90041	14	160-5A221 299	5685011014	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	Apartment			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.1328	-118.21674	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.64 KW. USING 36 PANELS. PV1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41558	18041-10000-16030	11640 W BURBANK BLVD	91601	2	174B169   877	2350001901	PF-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.17199	-118.38586	Plan check for a replacing an existing fire alarm system in a (3) story building. Scope includes (1) fire alarm panel, (4) control panels, and (281) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41559	16041-10001-03730	5401 N SHIRLEY AVE	91356	3	174B117   649	2164017008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.16903	-118.55798	Replace the 100A load center with 60A-Enphase Load center. (Rev. w/ A.F. & M.Z.). This is PC only, permit under master E#.  No fees due to SB 1222.<<PV1 roof mounted system to a single family home. Microinverter total rating system: 11kw. (44) modules. (100) A Load center with a monitoring system.Note: Low permit fees and $0 fee due to SB 1222>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41560	11041-10000-21485	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	11/10/2011 12:00:00 AM		Permit Finaled	01/05/2012 12:00:00 AM	ADDRESS	34.07594	-118.35916	NEW PV SYSTEM CAR PORT INSTALLED , 211 KW, COMMERCIAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41561	10041-10000-06883	245 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			04/15/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04986	-118.22649	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41562	16041-20000-25006	3355 S OVERLAND AVE	90034	5	120B161   422	4254024024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			07/15/2016 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	11/30/2022 12:00:00 AM	ADDRESS	34.02662	-118.41332	New 41-unit 6-story apartment building over 1 story parking garage and 1 level sub-grade parking garage.  1200A 208Y/120V service.  100kW emergency generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41563	19041-20000-04321	6323 N EUCALYPTUS CT	91316	5	177B125  1014	2123022053	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.1845	-118.52623	Plan check for a PV1 roof-mounted PV system. System size is 11.7 kWdc/10.48 kWac-CEC and consists of (2) inverters, (39) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41564	13041-20000-32923	7810 W GRANITO DR	90046	4	150B177   485	5551005025	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.10426	-118.36061	PV1 LOW FREQUENCY TRANSFORMER. TOTAL SYSTEM SIZE 16.56KW. 48 MODULES ADN 2 INVERTERS. ***LOW PERMIT FEES DUE TO 2012 SENATE BILL***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41565	17041-10000-36951	10432 N SEPULVEDA BLVD	91345	7	207B145   734	2649019009	C2-1, P-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	PIN	34.26038748	-118.46690796	ADD NEW DEVICES AND TIE TO EXISTING PANEL.	N	N	Express Permit	06/10/2024 12:00:00 AM
41566	14041-10000-24381	11384 W NUTMEG AVE	90066	11	111B161   201	4217003006	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.00191	-118.41461	Installation of roof mounted solar PV array.  Total system size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41567	10041-20000-15687	14812 W OXNARD ST	91411	2	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	10/12/2011 12:00:00 AM	ADDRESS	34.17923	-118.45564	PLAN CHECK POWER AND ENERGY FOR T. I. FOR NEW DIALYSIS. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41568	13041-10000-35220	444 S FLOWER ST # 1780	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLANCHECK FOR T24 ENERGY ONLY. INTERIOR T.I. ON THE 17TH FLOOR. SUITE 1780. 1792 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41569	11041-20000-19244	4277 S WESTERN AVE	90062	8	114B193  1268	5021027027	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM	09/12/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	34.00572	-118.30915	Plan check T24 Energy/Emergency for Children's Institute classroom. Permit for new ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41570	13041-20000-34315	3456 S MOTOR AVE	90034	5	120B161   364	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.02698	-118.40853	PC FOR T24 ENERGY ONLY. NEW LIGHTING. FAST FOOD. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41571	18041-10000-41855	212 N ARDEN BLVD	90004	4	138B189   623	5515017008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			Reviewed by Supervisor	11/08/2018 12:00:00 AM	ADDRESS	34.07504	-118.32584	PLAN CHECK FOR ROOFTOP MOUNTED 7.6 PV SYSTEM WITH 2 TESLA POWER WALLS (13.5) KW,  (26) MODULES, WITH  P400 POWER OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41572	16041-20000-40953	10248 ANGEL LANE	91331	7	204B165   430	2537004040	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25687173	-118.40430285	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41573	18041-20000-20718	5616 N HAZELTINE AVE	91401	2	174B153   735	2246032018	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	Apartment			06/05/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.17272	-118.43979	Plan check for Title 24 Energy only in parking garage of 5 units appartment. Total area: 5485 sq ft.B#16010-10000-03958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41574	18041-20000-28777	5474 E ALHAMBRA AVE	90032	14	139-5A237  18	5220029021	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			Corrections Issued	07/31/2018 12:00:00 AM	ADDRESS	34.07844	-118.1658	Plan check for 600A service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41575	12041-20002-30797	14402 W HAMLIN ST	91401	6	180B149   633	2237023020	(T)(Q)RAS4-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			04/17/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.18841	-118.44675	CHANGES TO APPROVED SET OF PLANS. CHANGING FROM FULLY RATED TO SERIES RATED ONLY.Plan check for power and energy (energy is per applicant request). Fire alarm variance has been filed. 25 unit three story apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41576	10041-20000-12092	8411 N CANOGA AVE	91304	12	192B105   314	2779022075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Expired	01/07/2011 12:00:00 AM	ADDRESS	34.22248	-118.5977	ADD STORAGE ROOMS IN (E) MFG<<PERMIT BE EXPIRED 30 DAYS FROM ISSUANCE PER INSPECTOR'S NOTICE>>Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41577	17041-10000-25053	13600 W VAUGHN ST	91340	7	213B157   725	2523004045	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.27692	-118.42874	Plan check for title 24 only in existing space, replace indoor existing fixtues with LED fixtures.Total area: 14,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41578	15041-10000-15989	8635 W 3RD ST STE 1060W	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.07373	-118.38073	Energy plan check for an office TI located at the 10th floor, Room 1060W, of a high rise building. No new circuits, all circuit remain existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41579	17041-10000-02456	515 S FIGUEROA ST 2ND FLR	90071	14	130-5A209  98	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	T-24, PC FOR ENERGY ONLY. CHANGE OF USE PORTION OF THE BUILDING FROM OFFICE TO DAYCARE CENTER. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 14790 SQ. FT. B#16016-10000-30093	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41580	15041-20000-10100	1454 W 66TH ST	90047	8	102B193   250	6015016014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	33.97904	-118.30206	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (22) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41581	18041-10000-46483	3435 W WILSHIRE BLVD 8TH FL	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.06194	-118.29866	TI IN THE EXISTING COMMON AREAS OF 8TH FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. 2,400SQR FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41582	18041-10001-15219	7300 WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	33.93972	-118.42295	SUPPLEMENTAL CHANGES TO APPROVED SET LAX PROJECT. CHANGES APPLY TO DELTA 4 AND 5 ONLY. <<<PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT TO BUILD-OUT NEW OFFICES, TRAINING ROOM, CONFERENCE AND STORAGE ROOMS. RENOVATE EXISTING OFFICE AREAS FOR REUSE. BUILD NEW EQUIPMENT ROOMS AND STORAGE/SHOP AREA.  39,187 SF PROJECT AREABUILDING PERMIT # 18016 10000 11663>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41583	11041-20001-07764	600 S MAIN ST	90014	9	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.04505	-118.24989	revise emergency light fixture to 32 watts and add sensors in bathrooms and 2 additional circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41584	17041-20000-45075	20251 W CHAPTER DR	91364	3	165B113   109	2174023034	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Issued	01/03/2018 12:00:00 AM	ADDRESS	34.15006	-118.57724	Plan check for solar pv system w/roof-mounted array on SFD. Line side tap.11.4kW ungrounded system. (33) 305W pv modules.Each module has a 320W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41585	18041-10000-28751	2304 S SAWTELLE BLVD	90064	11	123B153   102	4260021014	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			Verifications in Progress	08/21/2018 12:00:00 AM	ADDRESS	34.03663	-118.43969	PC FOR ENERGY ONLY, CHANGE OF USE FROM RETAIL AND PARKING GARAGE TO RETAIL.  -INTERIOR REMODEL. NEW LIGHTING AND RECEPTACLE LOAD, 400 AMP EXISTING SERVICE. TOTAL SQ. FT. 5080. BLDG# 18016-10000-12603	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41586	18041-20000-41280	718 E WASHINGTON BLVD	90021	9	121-5A209 149	5131006004	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	PIN	34.02710342	-118.25699128	PV3.  Install 13.32 kW DC roof mounted grid tied PV system.  (37) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41587	15041-10000-30002	3010 S FIGUEROA ST	90007	9	120A203    40	5123020024	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.02461	-118.27803	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (ONO HAWAIIAN BBQ).  SCOPE INCLUDES NEW LIGHTING, AND TWO NEW PANELS. TOTAL AREA IS 2025 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41588	19041-10000-06944	1243 W DENNI ST	90744	15	033B201   613	7415020029	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			Plans on Hold	03/04/2019 12:00:00 AM	ADDRESS	33.78423	-118.2795	pc for (1) LG chem 5kw battery.**** PC only. Duplicate to another Plan check submitted for solar and battery for the same address***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41589	16041-10001-01624	705 W MAC ARTHUR AVE	90731		021B197   748	7448005013							Electrical	Electrical	1 or 2 Family Dwelling			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	33.75069	-118.29268	PC only, Permit under Master E#. Increased size of the main breaker from 60A to 100A.  All other remain the same.<<PV1, ROOF MOUNTED SOLAR SYSTEM. (8) MODULES AND (1) INVERTER-3.0KW.  TOTAL SIZE IS 3.0KW.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41590	12041-10000-11276	621 S WESTERN AVE	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	09/10/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	NEW TENANT SPACES  CONVERTED TOFITNESS CENTER. ON THE SHELL DRAWINGS, THE TENANT SPACES WERE TO BE RETAIL SPACES FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41591	19041-10000-38411	15566 W RAYEN ST 1-31	91343	6	195B141   389	2654015017	(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Apartment			09/24/2019 12:00:00 AM			Corrections Issued	09/24/2019 12:00:00 AM	ADDRESS	34.23174	-118.47244	NEW FIRE ALARM IN AN APARTMENT COMPLEX. SCOPE INCLUDES NEW FIRE ALARM PANEL, ANNUNCIATOR AND 102 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41592	17041-20000-00853	1330 S FEDERAL AVE	90025	11	129B149   243	4263015019	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	01/26/2021 12:00:00 AM	ADDRESS	34.04752	-118.45624	Plan check for power and energy. Project site is a new 5-story, 36-unit apartment building over (2) levels of parking garage. Total lighting area = 48,411 sq. ft.Note: Building application has been generated under 14010-20000-02950	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41593	19041-10000-03191	13438 W OXNARD ST	91401	2	177B157   881	2343021014	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	11/02/2019 12:00:00 AM	ADDRESS	34.17926	-118.42606	PC for 5.04 KW solar system.14 ac modules with micro inverters. modules are SPR-X22-360-D-AC. one 125A Panel - 1 Gateway.Residential. 2 14kwh tesla power walls	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41594	11041-10000-15975	11007 W VENTURA BLVD	91604	2	162B173   462	2366023013	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.14075	-118.37052	T.I.  Existing 7-11 store.  Renovating the light fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41595	19041-10000-26366	9027 N CANOGA AVE STE G	91304	3	195B105    39	2779018039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.23429	-118.59779	T-24, PC for energy only. Remove HID fixtures and replace with new LED fixtures (Indoor Only) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41596	19041-10000-39436	8656 N SEPULVEDA BLVD	91343	6	195B145   525	2654021132	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	09/21/2020 12:00:00 AM	ADDRESS	34.22784	-118.46743	ENERGY PC FOR INTERIOR AND EXTERIOR TENANT IMPROVEMENT OF EXISTING DRIVE-THRU RESTAURANT. AREA OF SCOPE 2924SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41597	13041-10000-28183	2636 N HURON ST	90065	1	142-5A219 105	5446010008	UC(CA)	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Issued	10/22/2013 12:00:00 AM	ADDRESS	34.08519	-118.22202	POWER PLAN  CHECK. PROPOSING A NEW 600A  ,3-PHASE OVER HEAD SERVICE, FEEDING (3) 200A SUBPANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41598	17041-10000-39668	4322 W WILSHIRE BLVD	90010	4	132B189    51	5090030009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.06163	-118.32226	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PC FOR ROOF MOUTED PV ON A COMMERCIAL BULIDING. SYSTEM SIZE 98.16 KW DC / 113.3KWACSCOPE INCLUDES 308 MODULES (320W) WITH OPTIMIZERS (P700)SYSTEM COMPRISED OF 5 CENTRAL INVERTERS RATED AT 3PH 480V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41599	17041-10000-16564	3418 E LEE ST	90023	14	121-5A225 263	5188019028	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.02584	-118.20141	Installation of new roof mounted solar array on existing single family dwelling.  Central inverter system.  Total system size = 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41600	12041-20000-10210	4222 W PICO BLVD	90019	10	129B185  1095	5082023024	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM			PC Approved	04/12/2012 12:00:00 AM	ADDRESS	34.0477	-118.32765	Plan check for energy and emergency lighting. 1349 conditioned sqft. Single story commercial. Mateo's Ice Cream and Fruit Bars.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41601	16041-10000-25971	6801 W HOLLYWOOD BLVD A3-321C	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.10229	-118.33907	Plan Check for T-24 only. TI on (E) restaurant. Install new lights, receptacles and 2 panels with newly connected load < 400A. Total affected area: 1,600 sq.ft.(B# 16016-10000-16478)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41602	15041-20000-14952	7333 N FALLBROOK AVE	91307	12	186B097   826	2021018016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.2036	-118.62363	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (1) inverter, and (16) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41603	19041-10000-29403	19191 S VERMONT AVE #300	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR T24 ONLY, SCOPE OF WORK IS A TI IN THE THIRD FLOOR OF AN EXISITNG HIGHRISE. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES, AND CONTROLS. TOTAL AFFECTED AREA IS 19107 SQFT. B#: 19016-10000-23423	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41604	18041-10000-25204	6312 W YUCCA ST	90028	13	150A187   371	5546004027	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.10361	-118.32728	SERVICE UPGRADE TO 600 AMP. CORE & SHELL ONLY. INSTALL NEW PANELS FOR FUTURE TENANTS. THERE ARE NO LOADS CONNECTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41605	17041-10001-14839	14000 W DAVENTRY ST	91331	7	207B153   624	2618006011	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.2633	-118.43838	Plan check changes to approved set. Changing pv modules to  lg320n1c-g4  (11) 320W  from 260w modules (13)******************************plans to be signed 6/12/2017 ******************************3.8kW ungrounded system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41606	11041-20000-23436	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM			PC Approved	11/02/2011 12:00:00 AM	PIN	34.12750533	-118.21285206	Removing existing light poles and adding new lighting underneath new solar racks.  Also adding new post at the entrance of the parking lot.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41607	11041-10000-15257	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	12/09/2011 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	PIN	33.94363002	-118.42513364	T.I.  Federal Express Hangar.  1 out of 3 applications.  This application deals with the power portion (single line diagram) of the project along with showing the lighting side of the office space that is to be remodeled.  This application also shows the floor plan that reflects the permanent installation of the 2 story modular unit (not state approved).  This plan reflects all panels involved in the project.  Panels LH1N and panel Mod can be found on the modular plan set.  The T-24 calcs and the plans for the modular unit are submitted under 11041-10001-15257 and 11041-10002-15257 respectively.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41608	17041-10000-21294	15709 W ROMAR ST	91343	12	204B141   647	2661018002	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.25471	-118.47434	PC FOR ROOF MOUNTED PV SYSTEM USING 1-CENTRAL INVERTER(SOLAR EDGE SE5000A), 18-POWER OPTIMIZERS(P300) AND 18-MODULES(GES-6M255). SYSTEM SIZE 5.0 KWAC. NEW PANEL INSTALLATION WITH GROUNDING METHOD(#2 AWG).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41609	16041-10000-20674	10806 N EL DORADO AVE	91331	7	207B157   213	2619016004	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	34.26663	-118.42555	PV1 SFD TOTAL SYSTEM SIZE 4.3KW AC USING MICROINVERTER SYSTEM WITH 20 MODULES. USING ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41610	19041-10000-28665	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Issued	07/25/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	PC for T24 only per inspectors request, scope of work includes new lighting and controls and equipment in a conscession stand. Total affected area is 1007 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41611	13041-10000-22730	3906 S WELLINGTON ROAD	90008	10	117B185   905	5045014024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.0153	-118.33885	PV1 ROOF MOUNTED SOLAR INSTALLATION (UNGROUNDED/TRANSFORMERLESS). SYSTEM SIZE IS 4.165 KW DC AND 5KW AC. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: POWER-ONE # AURORA PVI-50000-OUTD-US-Z]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41612	11041-10000-07707	1800 S FIGUEROA ST	90015	9	124-5A205 147	5126009005	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	05/06/2011 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.03562	-118.27103	TENANT IMPROVEMENT  FOR CORPORATE  OFFICES;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41613	14041-20000-11772	19130 W NASHVILLE ST	91326	12	210B121   713	2718016007	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.26865	-118.54986	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. 13 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41614	17041-10000-31567	235 W 60TH ST	90003	9	105B201   488	6005014024	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	33.98523	-118.27718	PC for rooftop solar for addition of 3.29kW solar system to existing PV system. Intalling 14 new modules with microinverters and one 100 A subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41615	16041-10001-11498	4751 N ALLOTT AVE	91423	4	168B157   363	2359021011	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.15728	-118.42806	PV1. PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(17)MODULES-CANADIAN SOLAR CS6K-275M(1)INVERTER-SOLAREDGE SE3800A-USNOTE: PERMIT PAID UNDER PCIS#16041-90000-11498((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41616	19041-20000-48257	7801 N SHOUP AVE	91304	12	189B101   669	2013013021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.21213	-118.6149	PV1.  Install 6.6 kW DC roof mounted grid tied PV system.  (20) modules with 5 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41617	17041-10000-20727	523 W 6TH ST 6TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC FOR RESTROOM AND ADA COMPLIANCE TI  IN HIGH RISE BLD ON THE SIXTH FLOOR. TOTAL AFFECTED AREA 200 SQ.FT. BL # 16016-10000-24634BL# 17016-10000-03535	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41618	09041-20004-24367	3327 E SABINA ST Bldg B	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			11/03/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 5 Revision to approved plans for New Apartment Complex w/ multiple buildings (Bldg B) 2of 2 Building. Changes includes lighting, provide disconnects for ATS, relocate boilers and recirculation pump ckts, add lighting/fan ckt and revise meter phasing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41619	18041-10000-28971	9223 N OWENSMOUTH AVE	91311	12	198B105   134	2746012039	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.238	-118.60204	Permit fee is $0.00 due to Senate Bill 1222.New Rooftop solar system (PV2) on a commercial building. System size 502.2 kW DC/ 449.323 kW AC CEC/ 400 kW AC. (1407) modules, with P730 power optimizer. (4) central string inverter at 100kW each. System interconnect to New 600A service, 480/277 V.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41620	11041-20000-22461	10112 W EMPYREAN WAY	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Apartment			10/20/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.05362	-118.40912	Replace existing main switchboard and meter banks. Existing service to remain, existing feeders to be reconnected to new switchboard and meters. methane zone. no work in hazardous area. No change to unit existing loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41621	16041-20000-11996	1000 W WILSHIRE BLVD #1830&1850	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.05085	-118.26078	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR OFFICES. HIGHRISE . SUITE 1830 + 1850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41622	19041-20000-15710	8975 W FOOTHILL BLVD	91040	7	207B185   384	2547012003	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM			PC Approved	04/29/2019 12:00:00 AM	ADDRESS	34.26256	-118.32762	PV1INSTALL ROOFMOUNTED PV SYSTEM SIZED 3.8KW AC INERCONNECTED WITH MSP.THIS IS PLAN CHECK ONLY, PERMIT FEES PAID UNDER APPLICATION NUMBER 19041-90000-05052	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41623	18041-20000-19496	1947 N CANYON DR	90068	4	150A191    78	5586023001	R1-1-HPOZ	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/05/2018 12:00:00 AM	ADDRESS	34.10649	-118.31711	Plan check for the addition of a Tesla PowerWall onto an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41624	15041-20000-36196	600 WORLD WAY SPACE 684	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	PROPOSED 573 SQFT.  FINAL TENANT IMPROVEMENT FOR RETAIL  IN EXISTING SHELL SPACE IN ARRIVALS LEVEL .  Access HollywoodPC for Power & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41625	17041-10000-01629	3623 N CAHUENGA BLVD	90068	4	159B177   160	2425005010	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.13441	-118.36007	Plan check for Title 24 only in existing space T.I. retial space total area: 1680 sq ft. Load is less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41626	15041-20002-31204	21440 W VILLENA AVE	91364	3	168B105   623	2171002022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.15611	-118.59793	Changes to an approved set. Removing DWP performance meter and keeping an existing main service panel. permit under pcis#15041-20000-31204/E15VN02658(((PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(23) Hanwha G3-270W Modules(1) Solar Edge SE6000 Inverter)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41627	14041-20000-08769	826 E TRACTION AVE	90013	14	127-5A215  98	5163013005	(T)(Q)CM-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.04473	-118.23534	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. NO CHANGE IN OCCUPANCY, <400 AMPS IN CONNECTED LOAD. 7700 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41628	17041-10000-34104	20755 W VOSE ST	91306	3	183B109   350	2137019022	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Issued	09/22/2017 12:00:00 AM	ADDRESS	34.1984	-118.58589	PC FOR ROOF MOUNTED PV ON SLD. SCOPE INCLUDES 18 MODULES WITH OPTIMIZERS (300W) IN A SINGLE INVERTER SYSTM. SYSTEM SIZE 5.0 KWAC/ 5.4 KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41629	17041-10002-44218	1650 S WESTMORELAND BLVD	90006	10	126B193   367	5074018004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Issued	01/24/2018 12:00:00 AM	ADDRESS	34.04303	-118.30641	PC FOR ESS IN CONJUNCTION WITH PV WORK ON THE MASTER PLAN. PC FOR ROOFMOUNTED PV ON SFD WITH ESS SYSTEM INSTALLED (UNDER SUPP. APPLICATION).SYSTEM SIZE 3.0KWAC ADN 4.4KWDC SCOPE INCLUDES 11 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41630	12041-10000-08065	14711 W GLEDHILL ST	91402	7	198B149   107	2650031011	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2012 12:00:00 AM	04/09/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.24151	-118.45414	New 10.464kw rooftop, photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41631	18041-20000-06492	14724 W VENTURA BLVD	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM			PC Info Complete	03/21/2018 12:00:00 AM	ADDRESS	34.15162	-118.45395	PLAN CHECK FOR T24 ONLY FOR TI-PARKING UPGRADE INCLUDING NEW MEAN EGRESS AND ADA UPGRADES - TOTAL AFFECTED AREA = 2374 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41632	14041-10000-26504	103 N BOYLE AVE	90033	14	129A221   187	5174024041	R3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.04744	-118.22009	Title 24 plan check for a bakery commercial building. total area is 1141 SQ feet. Plan check only; inspection is based on permit # 14041-10000-25499.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41633	18041-10000-45685	14727 W FRIAR ST	91411	6	180B149   961	2241002022	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.18583	-118.45408	PLAN CHECK FOR FIRE ALARM SYSTEM FOR USING 1 FIRE ALARM PANEL AND 14 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41634	18041-20000-25861	3607 S TROUSDALE PKWY 301	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.02013	-118.28566	Plan check for Title 24 Energy only in existing space Steven & Kathryn Sample Hall(SKS) T.I. room 310 Total area: 532 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41635	16041-10000-26389	12100 W WILSHIRE BLVD STE 680	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	PC FOR ENERGY ONLY. TI FOR OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTECALES TOTAL AFFECTED ARE: 921 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41636	16041-10000-20657	643 E 25TH ST	90011	9	120A207   197	5127009020	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.02305	-118.26139	PV1 INSTALL NEW 3.71 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41637	12041-10000-23128	1537 N NORFOLK ST	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.06138	-118.20223	INSTALL 1 NEW CHILLER, 4 NEW PUPMS AND I NEW EXHAUST FAN IN AN EXISTING COMMERCIAL BUILDING. Applicant is requesting EPC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41638	18041-10000-12867	1400 S LOS PALOS ST	90023	14	117A229     8	5192001001	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.01638	-118.19487	PC FOR NEW FA SYSTEM IN OFFICE SPACES FOR COMMERCIAL COOLING SITE LEVELS 1-3.TOTAL DEVICE COUNT 277 WITH 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41639	19041-10000-19125	5343 W IMPERIAL HWY Suite #900	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	33.93128	-118.37337	"INTERIOR OFFICE TI  TO AN EXISTING COMMERCIAL OFFICE BUILDING IN SUITE #900. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. EMERGENCY LIGHTS ARE EXISTING TO REMAIN.""COMPLY WITH DEPARTMENT ORDER effective date 04/07/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".BULDING PERMIT: 19016-10000-15071"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41640	16041-10000-27765	21415 W ROSCOE BLVD	91304	3	192B105   593	2779036014	C2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.21995	-118.59813	Plan check for T-24 only. Remove outdoor HID fixtures abd replace with LED fixtures. Total affected area: 75,179 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41641	16041-10000-41399	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.27455	-118.56289	Plan check for power and energy for plance of assembly existing 2 story building T.I. Total area: 45,802 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41642	17041-10000-04631	20105 W RINALDI ST BLDG S3	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.27543	-118.57209	PC FOR POWER AND ENERGY. NEW BUILDING S3  - SHELL ONLY COMMERCIAL BUILDING, 1 STORY, SERVICE 600A 277/480 V, TOTAL AREA 2548 SQ FT.B# 16010-10000-06143	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41643	19041-10000-50299	8000 W MANCHESTER AVE	90293	11	096B153   618	4118002101	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Issued	03/06/2020 12:00:00 AM	ADDRESS	33.9594	-118.43534	$0 FEE PER AB1414. PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 196 MODULES (SPR-E20-435), WITH 196 OPTIMIZERS (SE P730) AND (2) INVERTERS (SE 43.2K ). SYSTEM SIZE IS 86.4KW AC AND 85.26KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41644	14041-20000-07710	3500 W 6TH ST Suite 110	90005	10	135B197  1016	5502030016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM			PC Approved	03/21/2014 12:00:00 AM	PIN	34.06344338	-118.29831795	T24 FOR EXISTING RESTAURANT. TOTAL RELOCATED LOAD DOES NOT EXCEED 400A. SCOPE OF WORK IS ON SUITE 110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41645	18041-10001-05928	7913 S KENTWOOD AVE	90045	11	099B165   197	4109018017	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM			Reviewed by Supervisor	03/05/2018 12:00:00 AM	ADDRESS	33.9703	-118.40209	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41646	11041-10000-00331	1830 S WESTERN AVE	90006	10	126B193   827	5074015045	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			Reviewed by Supervisor	02/24/2012 12:00:00 AM	ADDRESS	34.04077	-118.30873	CONSTRUCT NEW EXPRESS CAR WASH BUILDING WITH ACCESSORY OFFICE AND STORAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41647	19041-10000-32656	127 S LA BREA AVE	90036	5	138B181   989	5513019041	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	05/08/2020 12:00:00 AM		Permit Finaled	07/22/2022 12:00:00 AM	ADDRESS	34.07273	-118.34423	TITLE 24 PC ONLY FOR AN  INTERIOR REMODEL OF AN EXISTING SPACE. SCOPE OF WORK INCLUDES FIXTURES AND CIRCUITS.TOTAL AFFECTED AREA: 4,270 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41648	13041-20001-28135	4703 E DEL PASO CT	90032	14	135A231    47	5215029012	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.06545	-118.18341	((EXPEDITE FEES ONLY))PV1 TRANSFORMERLESS SYSEM. TOTAL SYSTEM SIZE 13 KW. 40 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41649	14041-10001-00784	6426 W LA PUNTA DR	90068	4	153A187   186	5576009112	R1-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.11387	-118.32917	Expedited plan check per applicant request.  (((PV1.  Install 9.43 kW AC roof-mounted PV system, interconnect with main service panel.  Microinverter: Enphase M215-60-2LL-S22.  45 modules: Trina Solar TSM-240 PA05.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41650	19041-10002-01293	961 S GRETNA GREEN WAY	90049	11	129B145   957	4264023016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.0466	-118.47066	PLAN CHECK ONLY. DELTA 1 CHANGES TO AN APPROVED SET.  SCOPE OF WORK INCLUDES THE SINGLE LINE REVISION TO INCLUDE THE CONNECTION OF AN EXISTING GENERATOR( UNDER SEPERATE PERMIT). ________________________________________ Original Scope of Work : (PLAN CHECK FOR ROOF MOUNTED 7.6KW PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 29 MODULES USING P400 OPTIMIZERS AND 2 13.5KWH AC BATTERIES(TESLA POWER WALLS) )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41651	12041-20002-23469	11831 W VOSE ST	91605	2	183B169   185	2321004004	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.19855	-118.39129	"(((11/22/2013: Changes made to approved set of plans. Changes in Emergency lights and lowbay lights)))Changes to previously approved set of plans. 3000A 480 3-phase service changed to a 800A 3-phase delta service. Changes to voltage drops and fault current, all equipment inside building is the same as previously approved.  Plan Check Only for ""DELTA B"" Changes on page E2.0 & E2.1.NEW WAREHOUSE / OFFICE BLDG -"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41652	19041-20000-28719	4549 N CARPENTER AVE pv1	91607	2	168B169   915	2364006030	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.15351	-118.39115	pv1install roof mounted pv system sized 16.5KW DC, 14.86KW AC CEC with 55 PV Modules and 2 inverters(7.6KW) interconnected with msp.Fees $ 0.00 Due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41653	17041-20000-18503	10386 N SEPULVEDA BLVD Suite 2D	91345	7	207B145   698	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	PIN	34.26066109	-118.46698849	TI, first time tenant.  plan check for power and energy.Building application number: 17016-20000-14559	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41654	14041-20000-08813	16542 W VENTURA BLVD SUITE 500	91436	5	168B137   369	2284005025	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.1576	-118.49393	TI to physical therapy center in 5-story commercial office building.   Title 24 plan check for changes to lighting system per inspector request.  Permit already obtained under 14041-90000-04733.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41655	12041-20000-24334	11765 W TENNESSEE AVE	90064	11	123B149   614	4260028017	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.03166	-118.44836	Plan check for PV system, single family dwelling. Microinverters. 4.8 kw DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41656	15041-20000-06582	8142 N LINDLEY AVE	91335	12	192B125   878	2101021007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.21867	-118.52717	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  1 central inverter with 3 strings (strings 2 & 3 are combined).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41657	10041-10000-23194	1415 S BUTLER AVE	90025	11	129B149   854	4405030037	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.04786	-118.45417	INSTALL A NEW FIRE ALARM SYSYTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41658	19041-10001-29753	6363 W WILSHIRE BLVD ste 516	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			PC Approved	10/23/2019 12:00:00 AM	ADDRESS	34.06385	-118.3674	PC ONLY -  CHANGES TO AN APPROVED SET OF PLANS TO REMOVE HIGH RISE DESCRIPTION AND REVISE EMERGENCY LIGHTING. -T.I to an existing commercial building.  adding new lighting new controls to existing panel. plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41659	12041-10001-24908	1111 W SUNSET BLVD	90012	1	136-5A211 440	5406020003	C2-2D	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			07/25/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.06583	-118.24918	changes to permitted set of plans-main cirvuit breaker will remain as was ; no changes to loadingRenovation of an existing 103 units appartment Bldg. EPC is for power & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41660	15041-20000-01388	11952 W SATICOY ST	91605	2	186B165   279	2317012014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	03/05/2016 12:00:00 AM	ADDRESS	34.20832	-118.3939	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41661	15041-10000-07333	9330 N CORBIN AVE	91324	12	198B117   119	2761036045	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.24028	-118.56213	TI TO AN EXISTING COMMERCIAL BUILDING.  CHANGING EXISTING LIGHTING FIXTURES TO LED.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 15668.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41662	19041-10000-49520	3100 W WILSHIRE BLVD	90010	10	132B197    34	5077011001	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2122.03	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.06164	-118.28935	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41663	19041-10000-52132	7802 N MELITA AVE	91605	2	189B157   800	2303010002	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.21191	-118.42068	NEW ROOF TOP PV1 SOLAR SYSTEM CONSIST OF 22 SUNPOWER AC MODLES  . SYSTEM SIZE IS 7.678KWAC 9.02KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41664	18041-10000-27854	5225 N SEPULVEDA BLVD	91411	4	172-5A145  97	2250002147	(Q)C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/05/2022 12:00:00 AM	ADDRESS	34.16562	-118.46644	Note: Permit Fees are $0 due to Assembly Bill 1414Install New Rooftop solar system on a commercial building, 42.25 KwPDC/ 37.775 kW AC CEC/ 33kW AC central inverter. (130) modules, (65) optimizer P700, (1) inverter, (1) 45 kVA transformer	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41665	19041-20000-00827	22984 W VENTURA BLVD	91364	3	171B097   613	2042006103	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	9304.01	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.16479	-118.62649	Plan check for a fire alarm system for a 1-story commercial building. Fire alarm system consists of (1) FACP and (62) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41666	18041-10000-22810	12000 W IDAHO AVE 1-34	90025	11	126B145   893	4259003006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.03918	-118.46049	Replace existing 4.4 kwUPS battery back up with a new one 6kw. PC for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41667	17041-10000-33815	400 S PACIFIC AVE	90731	15	015B197    62	7455003001	[Q]C2-1XL-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	33.74044	-118.28775	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41668	13041-10000-16418	750 S LAMAR ST MAINTENANC	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (6.) THE MAINTENANCE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41669	17041-10000-13630	8801 N ARLETA AVE TMP2	91352	6	195B161     1	2634003904	OS-1XL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1220.00	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Issued	04/26/2017 12:00:00 AM	ADDRESS	34.22931	-118.41286	PC AND PERMIT FOR 800A TEMP SERVICE FOR FUTURE CONVEYORS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41670	17041-30000-42718	11442 W VICTORY BLVD	91606	2	180B169  1159	2335021020	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Apartment			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.18641	-118.38048	Plan check for new Fire alarm system in 17 units appartment building. Fire alarm devices 70 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41671	10041-10000-13054	11925 W SANTA MONICA BLVD	90025	11	126B145   471	4263031032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	08/10/2010 12:00:00 AM	ADDRESS	34.04175	-118.46104	TENANT IMPROVEMENT AT A RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41672	18041-20000-39202	20726 W DUMONT ST	91364	3	171B109   371	2166032004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Issued	10/12/2018 12:00:00 AM	ADDRESS	34.16191	-118.58494	Plan check for a PV1 roof-mounted PV system. System size is 8.91 kWdc/7.6 kWac and consists of (1) inverter, (27) modules, (1) auto-transformer, (1) back-up load center, and (1) back-up battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41673	11041-20000-01540	2230 W 6TH ST	90057	1	133-5A203 110	5141003900	OS-1XL	Central	Westlake	MacArthur Park	YES	2088.00	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	ADDRESS	34.06036	-118.27704	Plan check new and replace lighting for MacArthur Park. In methane buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41674	18041-10000-39942	5849 S CROCKER ST Bldg L	90003	9	108B205  1217	6006029001	[Q]MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.98846	-118.26863	"REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY IN BUILDING ""L""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41675	12041-20000-29271	2601 S LA BREA AVE Unit #C	90016	10	123B181  1070	5049013047	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	12/17/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.03207	-118.35153	Change to lighting, receptacles, equipment in an existing subway restaurant.  Load is less than 400 amps and occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy.  Permit Fees are under INSPECTION.  NO EMERGENCY LIGHTING TO BE INSTALLED PER APPLICANT,  PLAN CHECK FOR EMERGENCY LIGHTING TO BE ON A SEPARATE APPLICATION IF REQUIRED.  (Additional Permit on #12041-90000-29294.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41676	15041-20000-40255	1985 E ZONAL AVE SUITE 600	90033	14	133-5A225  12	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.06159	-118.20463	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO LAB IN UNIT 600  AT USC PSC SATUFFER. 957 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41677	15041-20000-23754	17501 W RAYEN ST	91325	12	195B129   200	2768026009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Expired	09/04/2017 12:00:00 AM	ADDRESS	34.23232	-118.51605	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012Plan check for a PV1 roof-mounted PV system. System size is 16 kWac and consists of (3) inverter, (84) modules, (1) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41678	19041-10000-49109	335 N GAFFEY ST UNIT  1-23	90731	15	018B197   604	7447029013	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	Apartment			11/27/2019 12:00:00 AM	08/30/2021 12:00:00 AM		Issued	08/30/2021 12:00:00 AM	ADDRESS	33.74583	-118.29249	FULL PC FOR A NEW 1200A SERVICE (120/240 3p,4w) SERVICE FEEDS A NEW 1000A SWITCHBIARD CONTAINING ALL UNIT SUBPANELS AS WELL A 225AMP PANEL THAT FEEDS ALL ASSOCIATED HOUSE LOADS. TOTAL AFFECTED AREA IS 15,525 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41679	18041-20001-48713	10851 N BEE CYN	91311	12	207B101   586	2723005063	(T)(Q)RA-1-K, A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	01/14/2019 12:00:00 AM	ADDRESS	34.26749	-118.60732	Expedite per applicant request. Plan check for PV roof mounted system, system size: 13.86kW DC, 11.78kW AC with 42 PV Modules and 2 inverters(7.6kW) connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41680	11041-20000-07957	12200 W OLYMPIC BLVD #170	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM			PC Info Complete	04/20/2011 12:00:00 AM	ADDRESS	34.03195	-118.45506	ENERGY PLAN CHECK # 170	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41681	15041-20000-18894	6344 N TOPANGA CANYON BLVD SUITE 2040	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. MEDICAL OFFICE.  4659 SQFT. BUILDING A SUITE 2040.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41682	17041-20000-41853	15301 W VENTURA BLVD Suite 260	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for energy only. TI to office suite 260 in high rise building. New lighting (incl. emergency) - 2,380sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41683	14041-20001-11819	924 W ELYRIA DR	90065	1	148-5A221  68	5464013022	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.10208	-118.22079	Expedited plan check per applicant request.  PV1.  Install 4 kW roof-mounted PV system, interconnect with main service panel.  (16) modules w/ (16) Enphase M215 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41684	18041-10000-44837	7257 W SUNSET BLVD	90046	4	147B181   607	5548010022	C4-1D	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.09816	-118.3483	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 33117 SQFT AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41685	17041-10001-12220	6500 S CRENSHAW BLVD	90043	8	105B185  1251	4006015001	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM			PC Approved	03/15/2019 12:00:00 AM	ADDRESS	33.98048	-118.33066	"DELTA ""2"" CHANGES TO APPROVED PLANS FOR CHANGING THE LIGHTING & T-24.<<<Full plan check to existing building. Change of use from retail to coin laundromat. New service rated at 600 Amps120/240 V 3ph 4wire. All new equipment, New lighting and power. Total area: 11,650.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41686	11041-10001-19324	5348 N BOTHWELL ROAD	91356	3	171B117    51	2164018013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.16861	-118.56101	Revision to approved plans. Changes from 6000W to 8000W type inverter, modules type, and calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41687	10041-10004-05199	633 S MISSION ROAD	90023	14	124-5A219   3	5171015001	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/03/2011 12:00:00 AM	PIN	34.0373651	-118.22637397	Change the approved plan. Show the existing equipment on the plan. EPC is for delta 5 change. (((((((((((REPLACE THE DAMAGED SERVICE EQUIPMENT DUE TO FIRE.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41688	14041-20000-19342	650 E 35TH ST	90011	9	117A207   253	5121003027	[T][Q]CM-1VL	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Expired	11/07/2016 12:00:00 AM	ADDRESS	34.01421	-118.26368	Replacing 2 chiller, 240 amp each ,and adding (3) VFD unit to the #11-13 on MSA -16 (MCCR).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41689	14041-20000-12088	6909 N YOLANDA AVE	91335	3	183B121   815	2126018007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.19598	-118.54053	PV1Install roof-mounted solar array on SFD. System size: 6.75kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(27) Canadian Solar #CS6P-250PX pv modules(27) power optimizers 300W	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41690	13041-20001-03858	1733 N CHEROKEE AVE	90028	13	148-5A185  50	5547009016	[Q]R5-2D	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			04/26/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.1025	-118.33488	Changes to previously approved set of plans. Relocated distribution board. Changes to fault current and voltage drops.Plan check for service upgrade. Service upgrade and tenant panels plus house panel. No unit loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41691	10041-10000-22264	217 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04919	-118.22722	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41692	12041-20000-21101	1400 N GAFFEY ST	90731	15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	33.75723	-118.29183	Plan check for outdoor lighting. Canopy. 1500sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41693	14041-20000-28215	11620 W WILSHIRE BLVD	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	Plan check for energy only. TI/change of use to 1st floor of existing ~10 story high rise building. Yoga studio with new lighting (incl emergency). 5,350sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41694	18041-10000-47964	3030 N ANDRITA ST	90065	13	154-5A213 199	5458008013	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Info Complete	01/30/2019 12:00:00 AM	ADDRESS	34.11608	-118.24584	PLAN CHECK FOR TITLE 24 ONLY FOR INTERIOR TI ON 1ST FLOOR CORE/SHELL OF (E) OFFICE SPACE. TOTAL AFFECTED AREA = 16,127 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41695	19041-10001-13573	1 E WASHINGTON BLVD	90292	11	103-5A145  26	4226023006	C1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	33.97931	-118.46683	PC for a change of an approved set, change marked delta 1, change include relocation of switch only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41696	14041-20002-15782	330 N WESTLAKE AVE	90026	13	136-5A207  71	5157025043	(T)(Q)RAS4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			Reviewed by Supervisor	04/14/2017 12:00:00 AM	ADDRESS	34.06951	-118.26652	03/17/2017 Extensive changes throughout. All changes have been clouded and marked as Delta 3. Redesign of SLD - removed panels and transformers, some new panels relative to previously approved.  Some minor changes to underlying architectural design.  Extensive changes to lighting system.  Changes to mechanical HVAC equipment ratings.  *****Previous Work Description*****PLANCHECK FOR POWER AND ENERG. 200 UNIT APARTMENT. MIXED USE. 2 SERVICES OVER 3000 AMPS EACH. FEES CALCULATED PER ENGINEER. T24 FEES NOT CHARGED PROPERLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41697	12041-10000-27136	1900 S AVENUE OF THE STARS Suite 101	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	ADDRESS	34.05979	-118.41671	PLAN CHECK FOR ENERGY. TI TO EXISTING BUILDING. 965 SFInterior non-structural remodel to existing one-story office building to create new private offices.  No change of use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41698	16041-10000-08701	17383 W SUNSET BLVD FLR 1, 2-BLDG B	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, TI TO TWO RESTROOMS ON FIRST AND SECOND FLOORS,  SCOPE OF WORK INCLUDES NEW LIGHTS. TOTAL SQ. FT. 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41699	15041-10000-26628	7060 W HOLLYWOOD BLVD 2nd Floor	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	34.10137	-118.34379	9,991 sq ft. commercial office TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41700	19041-10000-51864	1012 S SAN PEDRO ST	90015	14	124-5A211 166	5132011024	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	09/26/2020 12:00:00 AM	ADDRESS	34.03545	-118.25182	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41701	17041-10000-39221	7222 N HASKELL AVE	91406	6	183B141    62	2206038007	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.20205	-118.47475	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41702	17041-10000-44866	6101 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	33.93236	-118.39253	REPLACE MCC CONTROL PANELS IN AN UPGRADED CARGO FACILITY OF KOREAN AIR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41703	16041-20000-14511	15455 W SAN FERNANDO MISSION BLVD	91345	7	210B145   128	2664007024	(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.27207	-118.46923	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the bathrooms on the 2nd, 3rd, and 4th floors. Total lighting area = 1,611 sq. ft.Note: Building application has been created under 16016-20000-08777	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41704	11041-20000-06395	5710 S CRENSHAW BLVD	90043	8	108B185   693	5006009008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	08/23/2011 12:00:00 AM	ADDRESS	33.99053	-118.33046	PLAN CHECK POWER AND ENERGY FOR RETAIL TI. CORE AND SHELL ELECTRICAL 600A SERVICE UNDER #11041-10000-02168.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41705	17041-20000-26732	4734 N LOUISE AVE	91316	5	168B133   369	2289010011	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.15599	-118.50963	ENERGY STORAGE SYSTEM 27KWH  ON EXISITNG SOLAR SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41706	14041-10000-31792	3377 W WILSHIRE BLVD	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.06193	-118.29742	T-24 plan check for the Restaurant. Total area: 2269 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41707	19041-10000-45911	18020 W CHATSWORTH ST 1-6	91344	12	207B125   637	2731008023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	04/22/2020 12:00:00 AM		Permit Finaled	07/18/2020 12:00:00 AM	ADDRESS	34.26474	-118.52473	TITLE 24 only, SCOPE OF WORK INCLUDES NEW LIGHTING, NEW CIRCUITS, AND EXISTING CONTROLS. TOTAL AFFECTIVE AREA: 31,362 SQ/FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41708	17041-20000-07228	3540 W WILSHIRE BLVD	90010	10	132B193    47	5094001002	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	04/20/2022 12:00:00 AM	ADDRESS	34.06157	-118.30171	change of use from retail/office to apartment/retail.  Adaptive reuse conversion of 13 story (high rise) commercial buiding with 205 units, using existing services.  Plan check for power and energy.BUILDING PERMIT # 17041-20000-07228	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41709	11041-10000-05965	20455 W DEVONSHIRE ST	91311	12	204B109   153	2707014001	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.25742	-118.57921	NEW CANOPY, 2 NEW DISPENSERS, 1 NEW PIC UNIT (PAYMENT MACHINE), NEW BOLLARDS (BUMPER POSTS) FOR AN EXISTING GAS STATION. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41710	15041-20001-03437	18528 W CHASE ST BUILDING A	91324	12	192B125   315	2785018029	R3-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Apartment			07/28/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.22434	-118.53707	07-28-2016 Changes on an approved set of plans. Changes include 1 additional panel and lighting fixture type changes in corridor. Changes apply to delta A only. *****************Previous Work Description************************************PC FOR 11 UNIT APARTMENT. TOTAL UNITS ON LOT 28. THIS IS SUBMITTAL 1 OF 2. THIS PLAN CHECK IS FOR 11 UNITS LOCATED AT BUILDING A. BOTH BUILDINGS ARE SERVED BY A SINGLE UTILITY TRANSFORMER.PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDSFIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41711	18041-20004-38403	9524 N SHOSHONE AVE	91325	12	201B129   410	2755009011	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.24414	-118.5176	4/2/2019changes to an approved set of plans.  changes to reflect field conditions.  200 amp MSP with 150 amp main.This is plan check only.  ((((pv1install roof mounted pv system sized 10.3KW AC interconnected with msp.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41712	18041-20000-45784	8934 N O'MELVENY AVE pv1	91352	6	195B165   246	2631007028	RS-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Issued	12/03/2018 12:00:00 AM	ADDRESS	34.23222	-118.39951	pv1install roof mounted pv system sized 5KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41713	18041-10000-22066	4466 N BECK AVE	91602	2	165B169    62	2365008020	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.15223	-118.38322	PERMIT FEE IS $0.00 DUE TO SENATE BIL 1222.NEW 12.6 (DC) KW, 11.2 (AC) KW PV SYSTEM WITH 35 PV AC MODULES, 2 TESLA BATTERIES, 2 SUBPANEL  AND SERVICE UPGRADE TO 400 AMPS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41714	13041-10000-09245	811 W WILSHIRE BLVD	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM			PC Approved	04/10/2013 12:00:00 AM	ADDRESS	34.04973	-118.2584	T24 FOR EXISTING OFFICE SPACE. 3535 SQRFT. TOTAL CONNECTED LOAD LESS THAN 400A. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41715	15041-20001-07189	6300 W WILSHIRE BLVD 10th floor	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.06319	-118.36591	3/12/2015 Supplemental application for full power plan check. The fees for the energy portion of the plan check have been paid under the master application. Supplemental application was generated for backroom expedite.*****Previous Work Description*****Plan check for Title 24. Project is a TI to the 10th floor of a high-rise building. Total lighting area = 18,690 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41716	14041-20001-24841	7010 S HOOVER ST Unit #7	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #7. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41717	10041-10003-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Addition and alteration to the TBIT.  The Core Design Notices in which each sheet  changes are noted. Changes include installation of power distribution equipment for power media elements and wall mounted information displays. Include CDN-164R1,-201,-093,-092,-133148R2,-133148R3,.Permit for new circuits, panels, and 10 additional inspection trips (Per Inspector)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41718	14041-10000-35779	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.06209	-118.34912	Non high rise, New fire alarm system including (1) fire alarm panel,  (5) power supplies and (661) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41719	13041-10000-31541	1417 W SILVIUS AVE	90731	15	009B193  1016	7470024015	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	33.71614	-118.30867	PV1, Install 3.75 kW DC roof-mounted photovoltaic system for 2-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41720	18041-10000-45796	2418 S HILLCREST DR	90016	10	123B181   619	5050005060	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.03432	-118.34128	PV1, ROOF MOUNTED SOLAR SYSTEM USING AC MODULES AND A SUB PANEL. TOTAL SYSTEM SIZE IS 8.64WDC/7.68 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41721	11041-20000-19212	12048 W VENTURA BLVD Which-Wich ?	91604	2	162B165   133	2369015016	(Q)C2-1VL, (Q)P-1VL, C2-1VL, P-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM			PC Approved	11/09/2011 12:00:00 AM	ADDRESS	34.1435	-118.39412	Rest. t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41722	16041-10001-45560	2005-2011 S HOOPER AVE	90011	9	118-5A213  36	5119031027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	34.02037	-118.24693	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE FEEDING EXIT SIGNS AND LIGHTS UNDER SAME CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41723	16041-10000-03187	6314 W HOLLYWOOD BLVD	90028	13	148-5A187 367	5546009***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	34.1014	-118.32715	T-24, CHANGE OF USE FROM RETAIL TO CAFE/ BAKERY WITH DINING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT.1095.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41724	13041-10000-12931	2833 S OLIVE ST	90007	9	120A205   125	5122011016	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.02358	-118.27308	PLAN CHECK ONLY FOR TITLE 24 AND EMERGENCY LIGHTING IN REFERENCE TO APPLICATION NUMBER 13041-10001-05423. TENANT IMPROVEMENT OF EXISTING WAREHOUSE **************************************************************SUPPLEMENTAL PERMIT TO 13041-10000-05423 TO INSTALL A NEW 400-AMP SERVICE & (10) NEW CIRCUITS.  COMPLY WITH DEPARTMENT ORDER DATED 2/4/2013, PERMIT TO EXPIRE 30-DAYS FROM DATE OF ISSUANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41725	18041-10000-19527	22748 W SATICOY ST	91307	12	186B097   262	2022008001	C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.20809	-118.62302	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41726	16041-20000-04233	14006 W RIVERSIDE DR #119&120	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check(per applicant request) for power and energy combine two tenant spaces into one to convert into a Gymnasium in existing mall.. Total area: 3,344 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41727	14041-20000-14026	16746 W COVELLO ST	91406	6	186B137    93	2226023021	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.20742	-118.49819	PV1.  Install 3.57 kW roof-moutned, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41728	15041-10000-42780	12180 W VENTURA BLVD	91604	2	162B165   201	2369004044	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.14307	-118.39788	T-24, TI TO A RETAIL SPACE,  ICE CREAM SHOP. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT.868.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41729	15041-20000-02513	2011 E ZONAL AVE LAB 210	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.06159	-118.20463	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LAB 210 IN USC HSC HMR. NO PATIENT CARE AREA. 459 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41730	15041-20000-19686	12630 W RAYMER ST	91605	2	186B161   566	2324003048	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.20343	-118.40847	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,550 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41731	19041-10000-03020	120 S SAN PEDRO ST 3RD FL	90012	14	129A213    16	5161017029	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Issued	03/28/2019 12:00:00 AM	ADDRESS	34.04937	-118.24147	T24 FOR EXISTING OFFICE SPACE, TOTAL SQUARE FOOTAGE = 7,990	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41732	15041-10001-16492	24500 W PAT PL	91367	3	177B085   536	2032014002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM			PC Approved	06/29/2015 12:00:00 AM	ADDRESS	34.17822	-118.65852	EXPEDITED RSES PLAN CHECKPER APPLICANT REQUEST.PV1, INSTALL 14.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(43) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-3.8 AND PVI-3.8 AND PVI 5000-OUTD -US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41733	15041-20000-43226	7416 N BELLINGHAM AVE	91605	2	186B165   508	2307025046	(Q)RZ3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.20531	-118.39872	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (24)MODULES-KYOCERA #KU2606ZPA(1)INVERTER- ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41734	18041-10000-29595	5265 W HOLLYWOOD BLVD	90027	13	148-5A195  59	5544009026	C2-1D	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.10191	-118.30557	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM NAIL SALON TO TEA SHOP. 1028 SQFT.BUILDING PERMIT # 18016-10000-25111	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41735	15041-20000-41543	23745 S PRESIDENT AVE	90710	15	042B193   542	7439004010	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	33.81018	-118.30419	PV system. Install a roof mounted solar array on a SFD. Interconnect with a 100A MSP.System size: 3.8kW. Ungrounded system. Using 300W power optimizers (one per module).(10) 255/235W pv modules on one string.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41736	13041-20000-25439	4117 W DON MARIANO DR	90008	8	114B181   563	5026004012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.00656	-118.3429	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6 KW AC USING 24 MODULES. 3 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41737	13041-10000-14140	1019 N AVALON BLVD	90744	15	033B205  1059	7420022020	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Closed	05/14/2014 12:00:00 AM	ADDRESS	33.78342	-118.26301	PLAN CHECK FOR POWER AND ENERGY. SERVICE UPGRADE TO 600A. 9 TENANT SPACES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41738	18041-10000-27182	5899 S BROADWAY	90003	9	105B201   189	6005006008	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Un		2392.01	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	33.98696	-118.27854	PLANCHECK ONLY FOR T24 ENERGY. Addition to existing church building. ELECTRICAL PERMIT PREVIOUSLY PULLED UNDER 18041-90000-08816BUILDING PERMIT # 16014-10000-04914	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41739	10041-10001-13090	960 N LA BREA AVE	90038	4	144B181   634	5531015004	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Closed	11/14/2018 12:00:00 AM	ADDRESS	34.08868	-118.34386	new plan check application  part paid on application # 10041-20000-13090, plan check is for power, lighting and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41740	14041-20000-33473	5438 N VENTURA CANYON AVE	91401	4	174B157   968	2344006009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.16969	-118.42902	pv1central string inverter standard plan system sized 6.375 DC kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41741	13041-20000-34532	2027 S STONER AVE	90025	11	123B149   274	4262032901	PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.03582	-118.4508	NEW CONSTRUCTION OF NATURAL GAS FUELING FACILITY. PC FOR POWER SYSTEM. CONTROL OF HAZARDOUS MATERIALS. ADDITIONAL PC HOURS HAVE BEEN ADDED. NEW OUTDOOR LIGHTING TO BE EXPEMT. INDUSTRIAL SITE. (((((((New 2000 amp SERVICE. system design changes. new engineer. new plan check. approved set of original has been attached for reeference purposes PERMIT FEES TO BE ISSUED UNDER INPECTION. PERMIT FEES ARE THE DIFFERENCE FROM ORIGINAL APPLICATION TO ADDITION OF WORK. ORIGINAL APPLICATION UNDER 13041-20000-34532. NEW PLAN CHECK WAS REQUIRED FOR NEW DESIGN BUT PERMIT FEES HAVE ALREADY BEEN HALF COLLECTED. THIS APPLICATION IS PART 2 OF 2)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41742	18041-20001-23625	6416 N ELLENVIEW AVE	91307	12	180B085   164	2032025001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.18599	-118.65775	07/20/2018 Changes to an approved set of plans. There has been an addition of (3) modules, for a total module count of (44), and module model and brand has changed. *****Previous Work Description*****PV1.  Install 13.4 kW AC roof mounted grid tied PV system.  (41) modules with (2) 7.6 kW rated string inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41743	18041-10000-28642	5343 W IMPERIAL HWY	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93128	-118.37337	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41744	15041-20000-30150	1827 E 103RD ST	90002	15	091-5A215 129	6048028935	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.9433	-118.23984	Installation of new fire alarm system in existing commercial building.  Total system size = 95 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41745	15041-10000-22814	5422 W CARLIN ST #1	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/31/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	PV1, INSTALL 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON COMMERCIAL BUILDING.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41746	18041-10000-18723	1756 N NORTH SPRING ST	90012	1	136-5A219  25	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Closed	08/22/2019 12:00:00 AM	ADDRESS	34.07007	-118.22546	CHANGE OF USE FROM WAREHOUSE TO ART GALLERYNORMAL LIGHTING SYSTEM WILL NOT CHANGEPLAN CHECK IS FOR ADDITION OF UNIT EQUIPMENT TO PROVIDE EGRESS ILLUMINATION	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41747	16041-10000-27929	2425 E MALABAR ST	90033	14	130-5A225 327	5177021019	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.05005	-118.20463	PV, INSTALL 2.6 KW DC ROOF-MOUNTED SOLAR ARRAY on a single family house.(10) modules: canadian solar csp6p-260(1) inverter: solaredge SE3000A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41748	12041-10001-25996	380 WORLD WAY SPACE 5C2-10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to lighting system of approved set: elimination of some cove lighting and replacement with downlights.  (((TENANT IMPROVEMENT ON 5TH FLOOR LOUNGE AT TOM BRADLEY INTERNATIONAL AIRPORT FOR KOREAN AIRLINE SPACE 5C2-10, 5, new lighting, title 24, power,  Total load of 152 Amps  Max verified fromk master plan.  Total actual load is 146 Amps.  Variance is filed to seperate fire alarm from power.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41749	14041-10000-00612	1458 S SAN PEDRO ST #316	90021	14	123A209   397	5132027***	M2-2D	Central		Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with fluorescent fixtures in 888 sq. ft. retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41750	14041-20000-06221	10910 W WALNUT DR	91040	7	201B173   145	2542011015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.25029	-118.36814	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12.0KWAC$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41751	18041-20000-14857	870 S HILGARD AVE 1-77	90024	5	135B153   384	4360007028	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Apartment			04/23/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Issued	05/09/2018 12:00:00 AM	ADDRESS	34.06469	-118.4407	Tenant improvement of existing apartment hotel.  New outdoor lighting and common area lighting.  Building permit under 17016-10000-35413	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41752	16041-30000-23034	6957 N FIGUEROA ST	90042	5	159A229   320	5480009019	OS-1XL	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.12876	-118.18798	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 4160.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41753	17041-20000-19001	825 N VINE ST Bldg B	90038	13	141B185   150	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Closed	02/11/2019 12:00:00 AM	ADDRESS	34.08603	-118.32689	Plan check for power and energy. New 3-story office building (Bldg B). Core and shell. Methane zone.3,000A service @ 480V 3ph-4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41754	19041-10000-11371	2575 W BEVERLY BLVD	90057	13	136-5A203  77	5157001001	C2-1	Central	Westlake	Echo Park		2086.20	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.06953	-118.27647	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41755	19041-10000-36744	6000 S WESTERN AVE	90047	8	105B193   415	6002016001	CM-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	33.9857	-118.30878	PC for a new fire alarm system in a commercial space (boaring house), scope of work  includes a new fire alarm panel and 33 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41756	19041-10000-48928	6925 N GAZETTE AVE	91306	3	183B109   668	2137023005	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM			PC Info Complete	11/26/2019 12:00:00 AM	ADDRESS	34.19643	-118.58754	[EPLAN] CHANGES ON APPROVED SETS. CHANGES ON BREAKERS ON THE SOLAR LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41757	15041-10000-34977	1854 S SAWTELLE BLVD 1-23	90025	11	126B153   436	4261020019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			10/20/2015 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.04272	-118.44498	New 5 story type IIIA mixed use construction over two levels type I suberranean parking. Two live-work units, new coffee shop commercial unit, and 23 residential units. Density bonus with 3 very low income units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41758	19041-20002-03607	5007 N AMIGO AVE	91356	3	171B121   562	2176014024	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM			PC Approved	07/10/2019 12:00:00 AM	ADDRESS	34.16118	-118.53944	07/10/2019 Changes to an approved set of plans. All changes have been clouded. PV module manufacturer and model have changed and count has reduced to (52) modules. *****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 17.08 kWdc/15 kWac-CEC and consists of (2) inverters, (56) modules, (3) load center, and (3) battery back-up units.Note: $0.00 permit fee due to CA Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41759	18041-20000-42889	11785 W GATEWAY BLVD 1-6-ms2	90064	11	120B153   323	4257006022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Apartment			11/08/2018 12:00:00 AM			PC Approved	12/07/2018 12:00:00 AM	ADDRESS	34.02692	-118.44407	interior remodel of existing six unit apartment building.  fees paid under application number 18041-20000-42884.this is plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41760	19041-10000-07236	5965 S ST ANDREWS PL Tent	90047	8	105B193   333	6001013906	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.98626	-118.3116	FULL PC FOR A NEW HOMELESS SHELTER(1 OF 2).  SCOPE INCLUDES A NEW 600A 480/277 3 PHASE 4 WIRE FOR A TENT STRUCTURE. NEW SITE LIGHTING AND CIRCUITS.  B#19010-10000-00856	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41761	13041-10000-28868	3901 N EAGLE ROCK BLVD BLDGD	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.11925	-118.23127	"INSTALLING FIRE ALARM SYSTEM,   APARTMENT BUILDING ""D"" (4 OF 7 buildings)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41762	24041-10000-10053	3525 W 8TH ST	90005	10	132B193   572	5093011013	(T)(Q)C2-2D	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.05782	-118.30714		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41763	19041-10000-36263	4707 S CENTRAL AVE	90011	9	112-5A209 362	5108022001	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Zapata-King		2292.00	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.00058	-118.25673	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41764	19041-10000-48593	901 N VINE ST	90038	13	144B185  1187	5533018001	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	04/04/2022 12:00:00 AM	ADDRESS	34.0873	-118.3268	PC FOR A NEW FIRE ALARM SYSTEM, SYSTEM INCLUDES A NEW FIRE ALARM PANEL, 3 POWER SUPLLIES, A COMMINUCATION PANEL, AND 180 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41765	15041-20000-16278	936 S OLIVE ST UNIT 357	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #5 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259.PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41766	17041-10000-06210	2049 S CENTURY PARK EAST 24th FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Issued	03/07/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC for TI 24 only in office area corridors. Luminaire replacement to lower rated luminaires, one for one replacement. Total affected area is 1920 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41767	10041-10000-08364	1213 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.05146	-118.22669	PV system for an appartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41768	16041-10000-16576	6150 W 96TH ST	90045	11	093B165   121	4124027906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Closed	01/22/2018 12:00:00 AM	ADDRESS	33.94871	-118.39284	PC for power only. Upgrading service from 600 to 800 A to an existing taxicab holding area assembly lot at Los Angeles International Airport. New switchboard 'msb' which feeds a new carwash panel and an existing distribution board 'mdb'.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41769	18041-20000-44397	2210 S GLENDON AVE	90064	5	126B157   277	4320001025	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	04/13/2020 12:00:00 AM	ADDRESS	34.04415	-118.43041	PV1.  ROOFTOP MOUNTED GRID TIED 9.44 KW DC PV SYSTEM.  (32) MODULES WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41770	11041-20000-11879	35 E MARKET ST	90291	11	108A143   444	4226007023	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	ADDRESS	33.98792	-118.47362	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41771	13041-20001-11135	1655 N HILLHURST AVE	90027	4	147B197   348	5542003022	RD1.5-1XL	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			PC Approved	07/02/2013 12:00:00 AM	ADDRESS	34.10105	-118.28763	Reduced scope of work. Changes to approved set of plans.T24 FOR EXISTING RETAIL SPACE PART OF A 2 STORY MIXED USE BUILDING. SCOPE OF WORK ON SUITE 102. 1010 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41772	12041-20000-28236	16830 W VENTURA BLVD 347	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check for energy and emergency lighting. 3217 sqft. Generator equipped. Suite 347.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41773	19041-20000-10082	1106 W PARK WESTERN DR	90732	15	021B197   334	7445013063	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2019 12:00:00 AM	03/20/2019 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	PIN	33.75420302	-118.2987001	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM. SYSTEM SIZE 9.9KW DC/10.8KW AC. SCOPE OF WORK INCLUDES (36) SW275 MONO BLACK  PV MODULES WITH (18) LS600 MICRO INVERTERS., AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41774	15041-10000-08422	1149 S HILL ST 8TH FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.03926	-118.26099	remodel open floor into USC SOCIAL WORK  STUDENT PROGRAMPLAN CHK IS FOR TITLE 24; A LIGHTING CONTROL SYSTEM HAVING THE FEATURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41775	14041-10000-24970	10535 N LANGMUIR AVE	91040	7	207A193   498	2556024029	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.2607	-118.30888	PV1, INSTALL 4.335 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(17) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41776	12041-20000-06000	6300 N CANOGA AVE 7TH FLOOR	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	03/15/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.18492	-118.59722	T. I. 1623 sq. ft., office space, plan check for lighting compliance, load <400A.(T.I. TO REMOVE AND INSTALL (N) NON-BEARING OFFICE PARTITIONS PER PLAN ON 7TH FLOOR OF (E) OFFICE BUILDING.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41777	16041-10000-25591	2732 W OLYMPIC BLVD	90006	10	129B197   217	5078011024	C2-1, P-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.05244	-118.29303	PLAN CHECK FOR T-24 ONLY. TENANT IMPROVEMENT TO AN EXISTING RETAIL BUILDING. INSTALL NEW LIGHTS, RECEPTACLES, AND 3 PANELS WITH NEWLY CONNECTED LOAD < 400A. TOTAL AFFECTED AREA: 965 SQ.FT.B# 16016-10000-16658	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41778	14041-20000-24848	7006 S HOOVER ST UNIT 5	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #5.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41779	19041-10000-26091	2909 E 1ST ST	90033	14	126A225    29	5180020032	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	07/06/2022 12:00:00 AM	ADDRESS	34.04092	-118.20313	PC for energy only to offce building. Indoor and Outdoor Title 24.  Addition of space for expansion of office. Adding new lighting and power. Total area: 1,341.Building Permit:  17041-10001-00505	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41780	14041-20001-26701	24374 W WELBY WAY	91307	12	183B089   741	2034005039	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM			Reviewed by Supervisor	10/15/2014 12:00:00 AM	ADDRESS	34.19393	-118.65649	Expedited plan check per applicant request.  PV1.  Install 17.7 kW DC roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41781	14041-10000-21186	2718 S FIGUEROA ST	90007	9	121-5A203 129	5123018032	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.02678	-118.27665	Changes to approved set by replacing kitchens lights with new lights. all changes are under delta-1 only.(((permit to be pulled at EPC counter only. PLAN CHECK FOR ENERGY ONLY (2008 standards). Taco Bell TI. BLDG#14016-10-08847: REMODEL TO EXISTING RESTAURANT,  FACADE REMODEL,  DINING ROOM REMODEL AND RELOCATION OF SOME KITCHEN EQUIPMENT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41782	18041-10000-19521	5125 S CRENSHAW BLVD	90043	8	108B185    30	5013018002	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	33.9959	-118.33113	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41783	13041-20000-03192	23907 W BESSEMER ST PV-1	91367	3	177B089   465	2045009001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.18082	-118.64725	Plan check for PV. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41784	17041-20001-17580	1349 N BEREA PL	90272	11	129B129    24	4422007039	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	34.05353	-118.52181	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTERS. SYSTEM SIZE: 16 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41785	13041-10000-20353	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	TITLE 24, PART 6 ENERGY PLAN CHECK AND PERMIT FOR LIGHTING. SCOPE OF WORK INCLUDES ADDITION OF TWO RETAIL STRUCTURES OVER THE EXISTING STRUCTURAL DECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41786	13041-10000-32353	5901 N SEPULVEDA BLVD STE # B	91411	4	174B145    17	2243001018	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.17752	-118.46645	TITLE 24 PART 6 ENERGY WORK; REMOVING (E) HID FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41787	14041-20003-01398	7734 N SALE AVE	91304	12	189B097  1032	2013017004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.21118	-118.6184	((change in service interconnection. 200A service. plan check only. no permit issued. $0 permit fee due to senate bill 1222 from 2012)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41788	15041-10000-27726	714 N ISABEL ST	90065	1	145-5A219 333	5453027005	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			Reviewed by Supervisor	09/10/2015 12:00:00 AM	ADDRESS	34.09183	-118.22116	PV 2 roof mounted solar system, 2.385 KW PV array.(9) modules: KYOCERA #KU2656ZPA(1) INVERTER: PVI-3.0-OUTD-S-US*NOTE: multiple meters in the building.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41789	12041-10001-04552	5800 W FOREST LAWN DR	90068	4	165B189    16	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.14432	-118.31518	CHANGES TO APPROVED SET OF PLANS. PV2 NOW: LINE-SIDE TAP AND WIRE SIZES CHANGED. before: panel (but no space to install so they used tap) and they said wire sizes were originally oversized. applicant will bring approved plansPlan check for new 135KW ground mounted photovoltaic system (parking canopy) at Forest Lawn Hollywood Hills. Upgrade to 600A panel on 400A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41790	17041-10000-10672	600 WORLD WAY #632	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM			PC Approved	04/03/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	Changes to approved set.  New lighting fixtures, updated Title-24 sheets, two subpanels replaced by one split-bus panel, and updated photometrics.Permit pulled under application #17041-10000-04712Plan check for Title 24 only for Peets Coffee T.I. at LAX Termila 6. Total area: 875 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41791	13041-20001-35998	20623 W BLACKHAWK ST	91311	12	204B109    93	2707011036	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.25832	-118.58273	pc for pv1 single family dwelling. total system size 5 kw ac using transformerless inverter nonstandard plna, using power optimizers((expedite fees)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41792	16041-10000-29876	512 S STANFORD AVE	90013	14	127-5A213 497	5147018034	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.04209	-118.24143	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 16091 SQ FT.(INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41793	15041-10000-15488	2452 S ROBERTSON BLVD	90034	10	126B169  1078	4302015037	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.03943	-118.38788	New 800A 480Y/277V service and electrical distribution system for (E) carwash.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41794	15041-10001-06525	6250 N TOPANGA CANYON BLVD BLDG F	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	(((7/9/2015- CHANGES MADE TO APPROVED SET. ADDING NOTE 21 TO ALL THE TENANT SPACES. CALCULATIONS TO BE REVERIFIED. ALL PERMIT FEES FOR REVISIONS ARE ON BUILDING A APPLICATION 15041-10001-06518)))NEW FIRE ALARM SYSTEM IN BUILDING F ON WESTFIELD PLAZA. 94 DEVICES AND ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41795	17041-20000-34876	7107 N PENFIELD AVE	91306	3	183B113   195	2135009027	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	06/30/2022 12:00:00 AM	ADDRESS	34.19947	-118.56893	Plan check for a PV1 roof-mounted PV system. System size is 10.7 kWac and consists of (31) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41796	13041-10000-07303	23956 W EAGLE MOUNTAIN ST	91304	12	193-5A091  53	2017023026	A1-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.22498	-118.64861	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING, TOTAL SYSTEM SIZE 6.3 KW. USING 26 MODULES, TRANSFORMERLESS INVERTER, NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41797	11041-10000-03675	965 N BEL-AIR ROAD	90077	5	144B153   625	4370023027	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.09107	-118.44103	Roof mounted 54.28 KW photovoltaic system for dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41798	17041-10001-44204	8750 S VERMONT AVE	90044	8	096A199   110	6038010904	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	ADDRESS	33.95806	-118.29132	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGES TO THE AIC RATING OF THE RESIDENTIAL SWITCHBOARD. ALL CHANGES ARE CLOUDED UNDER DELTA 4. DWP LETTER PROVIDED. PERMIT PULLED UNDER MASTER APPLICATION 17041-10000-44204(((PC for power and energy for 21 unit apartment 5 storie building with two levels of commercial. Installing new 3000A 208/120V service with three distribution boards, new panels, equipment and circuits. B#17010-10000-02540. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41799	16041-10006-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	33.94502	-118.40714	CHANGES TO APPROVED SET UNDER DLETA  ACI-004.SCOPE INCLUDES  ADDITION OF 2 PANELS, NEW CIRCUITS, NEW LIGHTS IN NEW SPACES AND REPLACING LUMINAIRES TYPE IN EXISITING SPACES. NEW LIGHTING AND POWER. SOME REVISIONS TO PANELS SCHEDULE. UPDATED T-24 FORM TO REFLECT NEW LIGHTING. PHOTOMETRIC REVISED FOR THE NEW SPACES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41800	18041-10000-07497	1622 E OLYMPIC BLVD 2nd floor	90021	14	123A213   329	5130004016	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.02947	-118.24141	On the second floor of an office/warehouse building, adding emergency lights and exit signs to existing nearby normal lighting circuit. J-boxes are used in the wiring.title 24 exemption	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41801	12041-10000-21488	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.07125	-118.35662	REMODELING  OF THE NORDSTROM STORE-FULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41802	13041-10000-34078	16900 W SHERMAN WAY # 14	91406	6	183B133   169	2227026004	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.20094	-118.5015	"TITLE 24 PART 6 ENERGY FOR ""LEE'S SANDWICH"" SHOP. SCOPE OF WORK < 400A. ADDING (1) FIXTURE IN RESTROOM. E-PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41803	17041-20000-34746	13113 W VAN NUYS BLVD unit c	91331	7	210B161   744	2535018026	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.26875	-118.41881	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41804	13041-20000-27699	13833 W OXNARD ST 1-24	91401	2	177B153   776	2239022004	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	10/04/2013 12:00:00 AM	ADDRESS	34.17954	-118.43442	T24 FOR OUTDOOR PARKING LOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41805	10041-10000-25490	2005 W PICO BLVD	90006	1	129A201   229	5136023031	(T)(Q)CM-1	Central	Westlake	Pico Union		2098.10, 2098.20, 2243.10	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	03/12/2012 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.04702	-118.28177	New two story office building with two levels subterranean parking.  EPC is for power & energy.  ***This project is a LEED Silver.***.  Two 600 ampere services of the same class have been installed in the electrical room.  The two services were allowed by special permission based on a DWP letter Dated March 21, 2011  from District Engineer of the East Area, Metropolitan Service Planning, Mr. Darrell A. Miller.  Stating to effect that the two services are being required by the DWP due to transformer loading limitaions.  The permit issued on this application number will include also the permit fees for application number 10041-10001-25490.  Fees are in ' Inspection ' NOT IN FINAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41806	14041-10000-10696	710-720 N EL CENTRO AVE 1-38	90038	13	141B189  1235		(T)(Q)RAS3-1	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Apartment			04/23/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.08386	-118.3243	FA FOR NEW 78 UNIT APT. 6 story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41807	10041-10000-13582	1389 S MIDVALE AVE	90024	5	132B153   880	4324008009	[Q]R4-1L	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Public Safety Only			07/15/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	34.05504	-118.44304	Fire alarm system for 5 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41808	19041-20000-28149	7660 N WILBUR AVE pv1	91335	3	186B121    26	2103015014	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.21009	-118.54462	pv1install of roof mounted pv system sized 3.8KW AC interconnected with msp.  this is an addition to an existing pv system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41809	16041-10000-04903	23104 W VANOWEN ST	91307	12	180B097    37	2038019011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.19352	-118.63024	PV1, rooftop solar installation 7kW system(21) SPR-327NE-WHT(1) Sunny Boy 7000TL-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41810	19041-20001-44787	5425 N ALDEA AVE	91316	5	174B133   788	2258001023	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM			Reviewed by Supervisor	11/13/2019 12:00:00 AM	ADDRESS	34.16985	-118.50821	EXPEDITEDPV1. INSTALL 12.285 KW DC PV SYSTEM WITH (39) MODULES/OPTIMIZERS, (1) INVERTER (SE11400H) AND (4) TESLA ENERGY STORAGE BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41811	17041-10000-19284	20832 W VALERIO ST unit #24	91306	3	186B109  1048	2113013***	(Q)RD2-1, (Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.20456	-118.58754	PC FOR PV SYSTEM ROOF MOUNED ON SFD. TOTAL SYSTEM SIZE 3.8KW AC USING 19 MODULES AND CENTRAL INVERTER, SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41812	14041-20000-09265	15350 W SHERMAN WAY #423	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.20099	-118.46808	T.I. to existing offices.  Install general/emergency lighting on the 4th floor.  Plan check for energy only.plan check only application. permit already issued.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41813	14041-20000-23777	8513 N GLORIA AVE	91343	12	192B141   208	2673002019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Expired	09/28/2016 12:00:00 AM	ADDRESS	34.22515	-118.48096	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41814	15041-20000-18087	2245 W YOSEMITE DR	90041	14	160-5A221  43	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.13556	-118.21671	Plan check for power and energy electrical distribution system rated 1,000A with new branch circuit for lighting and power equipment. Total area: 27,622 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41815	14041-20000-17988	415 S BURLINGTON AVE 1-30	90057	1	133-5A205 194	5154023014	R4-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Apartment			07/02/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.06012	-118.26997	PV1.  Install 12.8 kW DC roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41816	16041-20000-00993	22061 W PARTHENIA ST	91304	12	195B101   336	2010010022	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	34.22828	-118.60801	Plan check for PVground mounted system. System size: 13kW with 54 pv Modules and 54 microinverters connected to 200A panel and main breaker 150Abuilding permit # 16020-20000-00386	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41817	12041-20000-24710	9649 W LAWLEN WAY Guest-house	90210	5	144B161   412	4355019043	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.09484	-118.41636	Department error, zero fees.  New guest house.  Plan check fees paid on original application 12041-20000-07941.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41818	13041-10000-07294	11421 W CANTON DR	91604	2	159B169   239	2377010014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.13373	-118.38252	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 13.9 KW. USING 58 MODULES. MULTIPPLE INVERTERS TRANSFORMED, NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41819	16041-10000-25754	5731 S WILTON PL	90062	8	108B189  1193	5005012021	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	33.99004	-118.31508	PV1, INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MODULES: CANADIAN SOLAR CS6P-260(1) INVERTER:FRONIUS PRIMO 3.8-1 24V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41820	14041-10000-02186	5353 W IMPERIAL HWY STE 1000	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	33.93112	-118.37375	Tenant improvement for office suite.  New power and lighting w/ (E) distribution system.  Plan check for Title 24 for changes to lighting system. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.NOTE: PERMIT FEE ALREADY CALCULATED, UNDER INSPECTION FEE CATEGORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41821	16041-10000-20328	1727 E 107TH ST	90002	15	090A213   238	6065034901	OS-1XL	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	33.93871	-118.24178	T-24, PC FOR AN EXISTING PARKING LOT. SCOPE INCLUDES ADDING/REPLACING LIGHTS FOR AN EXISTING PARKING LOT AND EXISTING ROADWAY(PUBLIC RIGHT-AWAY). TOTAL AFFECTED AREA IS 28500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41822	14041-10000-25762	8635 W 3RD ST SUITE 475-WEST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.07373	-118.38073	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. NOT A PATIENT CARE ARE PER APPLICANT. 1135 SQFT, EMERGENCY LIGHTHING.  SUITE 475 WEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41823	15041-20000-09160	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	ADDRESS	34.30584	-118.47951	Title 24 plan check only.  Total area = 3,144 sq. ft.T.I. to existing space.  Renovation of open office to fitness center.  Scope of work does not include any medical areas.  All panels are to remain existing.  New branch circuits draw 47 amps of load (17 kVA).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41824	17041-10000-29452	560 S LOS ANGELES ST #5	90013	14	127-5A211  83	5148017009	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.04462	-118.2487	PC for T24 energy only, replace indoor existing fixtures with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41825	18041-10000-43913	5870 W JEFFERSON BLVD H	90016	10	120B173   383	4205027010	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.02285	-118.37583	Energy plan check for an office T.I located on the 1st floor of a commercial building. Scope includes new lighting and equipment with a total area of 3265-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41826	14041-10000-19354	1008 S BURNSIDE AVE	90019	4	132B181   701	5085009011	R1-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Expired	08/22/2016 12:00:00 AM	ADDRESS	34.0569	-118.35141	Installation of roof mounted solar PV array.  Total system size = 7.6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41827	17041-10001-36495	515 S FLOWER ST 18TH- 19TH-FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	01/04/2023 12:00:00 AM	ADDRESS	34.05134	-118.25661	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 8. CHANGES INCLUDE REPLACING EXISTING LIGHTING FIXTURES WITH NEW FIXTURES,  REVISING PANEL SCHEDULES, REVISING TITLE 24 CALCULATIONS,  AND ADDING NEW LIGHTING CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41828	15041-30000-39707	17324 W SAN FERNANDO MISSION BLVD	91344	12	210B133   471	2696001007	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Expired	12/27/2017 12:00:00 AM	ADDRESS	34.27186	-118.51175	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41829	10041-10000-17802	3844 S MOTOR AVE	90232	10	117B165   171	4208006025	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	01/12/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.01945	-118.40297	PROPOSED 3 STORY, 9 UNITS ( 4 TYPES) APARTMENT BUILDING (2 STORY HABITABLE OVER PARKING GARAGE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41830	14041-20000-19328	10856 N MOUNTAIR AVE	91042	7	207B197   161	2566012040	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.26702	-118.29479	PV1.  Install 7.128 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41831	14041-20001-29708	10008 N LEV AVE	91331	6	204B153   864	2645011024	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.25238	-118.43532	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(18) SUNPOWER SPR327 MODULES(1) POWERONE PVI 6000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41832	10041-20000-23526	333 S HOPE ST 31st.-floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	04/14/2011 12:00:00 AM	ADDRESS	34.05326	-118.25292	T.I. to existing high rise building at 31st. floor in the pantry area.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41833	12041-10000-11808	5550 W WILSHIRE BLVD 1-163	90036	4	132B181  1299	5089005***	[Q]C2-1-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.06206	-118.34979	First time tenant, for a restaurant.  New sub panels, circuits, and lighting.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41834	15041-20000-36364	19645 W SHERMAN WAY BLDG 5	91335	3	183B117     7	2116001090	C2-1VL, R3-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.20129	-118.56157	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 18 KWac. (70) MODULES-CANADIAN SOLAR CS6P255P(3) INVERTERS-SUNNYBOY SMA SB6000US-12(1) 125A SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41835	14041-20001-04124	7742 N AMESTOY AVE PV1	91406	6	189B133   819	2203007014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.21161	-118.50537	][] EXPEDITED PER APPLICANT REQUEST ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PNL. UNGROUNDED SYSTEM, SIZED @ 4.25 kW DC, WITH (17) TRINA #TSM-250PA05.18,  (17) OP300 OPTIMIZERS, (1) SOLAREDGE SE3800-US-ZB-U.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41836	16041-10000-32650	14954 W OXNARD ST	91411	4	177B145   484	2243022018	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.17916	-118.45938	Removing HID fixtures and replacing with new 81 LED fixtures PC T-24 only. Includes 13892 sqft of indoor and 10800 sqft of outdoor area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41837	11041-10000-03291	841 S LA PALOMA AVE Berth 163	90744	15	024B205    22	7440014***	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	05/09/2011 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	33.76076	-118.26497	Electrical service retrofit asjacent Berth 163.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41838	19041-10000-45458	7400 N COLDWATER CANYON AVE PV2	91605	2	186B161   521	2324001011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	34.20498	-118.41362	NEW UTILITY INTERACTIVE ROOF MOUNTED SOLAR SYSTEM WITH 22 PV MODULES AND 1 INVERTER ON A COMMERCIAL BULDING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41839	11041-10001-25687	100 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/28/2012 12:00:00 AM	PIN	33.94684048	-118.40128468	Changes made to previously approved set see clouds. speaker conductors changed from 14 to 16 awg.))))))))))))))))))))))))))))))))))))))))New fire alarm system for LAX Terminal 1.((((((((((((((((((((((	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41840	19041-10000-31819	707 E TEMPLE ST	90012	14	130-5A217 355	5173015009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	02/06/2021 12:00:00 AM	ADDRESS	34.05032	-118.23325	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41841	15041-10000-21665	425 W WASHINGTON BLVD	90291	11	105A147   164	4227021033	C4-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	PIN	33.98171082	-118.46299257	T-24, TI IMPROVEMENT ON EXISTING RESTUARANT. 3 NEW PANELS 200 AMPS. PC FOR ENERGY ONLY. TOTAL SQ. FT. 2885	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41842	15041-10002-44015	7417 N PONCE AVE	91307	12	186B097   638	2022007010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.20514	-118.62158	03/15/16Changes to an approved set of plans. Changes include adding a new LADWP PV meter on the single line diagram. Additional permit fees for Sun Run meter branch circuit. ((((PV1 roof mounted installation to a single family home. (1) inverter : 10 kw, (46) solar modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41843	18041-10000-09703	2221 W BERKELEY AVE	90026	13	142-5A207 233	5423010013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM			PC Info Complete	03/22/2018 12:00:00 AM	ADDRESS	34.08442	-118.2617	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 17 MODULES (EAGLE PERC60 290w), OPTIMIZERS (SOLAR EDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE5000A-US). SYSTEM SIZE IS 5KWac AND 5.44KWdc.THIS IS PLAN CHECK ONLY!PERMIT PAID UNDER 18041-10000-10465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41844	17041-10001-26145	2231 S WESTERN AVE	90018	10	123B193   238	5058009041	C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.01	Electrical	Electrical	Apartment			12/05/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.03519	-118.30929	Change to approved set by relocating the pull box, and updating service equipment with same rating from a different manufacutre. all fault current also being modified on the single line diagram due to the changes. All changes under delta-4 only.(((PC for power and energy for 60 unit, 6 story, and one basement level apartment building. PC for new 1200A 277/480 service, on site fire pump, emergency generator, new equipment and new distribution panels located in methane zone. This project is an adaptive reuse project converting from hospital to apartment building (17016-10000-18981). Total area 87751 sqft.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41845	13041-20001-20477	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	Modification to previously approved set of plans to add 4' of track lighting.  (Plan Check Only)             <<<T24 FOR RESTAURANT REMODEL. NOT A FIRST TIME TENANT PER APPLICANT. TOTAL SQRFT 1997>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41846	17041-30002-40286	6221 W 96TH ST	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	33.94902	-118.39331	Supplental for changes to T24. (WORD DESCRIPTION TO BE ADDED BY MEHDI)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41847	16041-10000-03078	6040 W CENTER DR	90045	11	102B169  7175	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	33.97574	-118.39042	Outdoor sign lights: ALTITUDE, RESIDENT PARKING, LEASING.. PC for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41848	13041-20000-30224	23720 W POSEY LANE	91304	12	186B089    67	2027035004	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.2097	-118.64532	PV1 TRANSFORMERLESS SYSTEM. 28 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41849	19041-30000-03759	11473 N VIKING AVE	91326	12	213B121   459	2871004008	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Issued	01/31/2019 12:00:00 AM	ADDRESS	34.27984	-118.54545	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 2.1 kWdc/1.9 kWac-CEC and consists of (7) modules, (7) micro-inverters, and (1) combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41850	18041-10000-16803	4201 W WILSHIRE BLVD	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Public Safety Only			05/07/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.06189	-118.31911	PC FOR A FIRE ALARM SYSTEM FOR AN EXISTING BUILDING. SCOPE INCLUDES 339 FA DEVICES AND 7 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41851	14041-10000-22520	7801 N NOBLE AVE	91405	6	189B145   553	2209036022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.2122	-118.46196	T24, REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 13798 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41852	15041-20000-18710	6320 N TOPANGA CANYON BLVD G-1635	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and energy. Project site is a new commercial space within the Westfield Village. Project scope is a first-time tenant, tenant improvement. Total lighting area = 2,815 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41853	13041-10006-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			06/30/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.10155	-118.31097	CHANGE TO AN APPROVED SET  WITH UPDATED  FAULT  CURRENT CALCULATION FROM DWP SECONDRY TO SERVICE EQUIPMENT.  DWP  ISC AT 68.5K (WIMS) AND SERVICE EQUIPMENT RATED AT 65K. A LETTER FROM DWP IS PROVIDED STATING FAULT VALUE AT TRANSFORMER SECONDRY. OWNER INSTALLED SERVICE ENTRANCE CONDUTORS WITH CALCULATIONS SHOWING FAULT AT SERVICE EQUIPMENT <65K.ALL CHANGES UNDER DELTA-14 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41854	12041-10000-15802	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM			PC Approved	07/09/2012 12:00:00 AM	ADDRESS	34.06307	-118.2	ON THE 1ST FLOOR, REPLACING LUMINAIRES IN EACH OF THE 6 RESTROOMS AND LUMINAIRES IN THE CORRIDORPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41855	15041-10000-39292	1440 S SEPULVEDA BLVD 1st Floor	90025	5	129B149    38	4324016094	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.05107	-118.44699	T-24. PC for energy only to a commercial building (existing office). TI on 1St floor. Adding new lighting and receptacles. Sq ft = 14549	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41856	19041-10000-22387	1120 N LA COLLINA DR	90069	4	144B165   209	4392015010	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM			Reviewed by Supervisor	07/17/2019 12:00:00 AM	ADDRESS	34.09169	-118.39562	POWER PLAN CHECK FOR A CHANGE OF USE FROM GUESTHOUSE TO ADU. SCOPE INCLUDE A NEW  800-AMP SERVICE 120/240V SINGLE PHASE  WITH NEW PANEL S AND RECONNECTED LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41857	19041-20000-39943	733 W 167TH ST	90247	15	066B197    34	6121006039	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	33.87998	-118.28809	PV1. INSTALL 8.14 KW DC PV SYSTEM WITH (22) MODULES/MICROINVERTERS (ENPHASE IQ7PLUS-72-2-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41858	15041-20000-27969	9180 N SAN FERNANDO ROAD	91352	6	198B169   147	2538008022	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.2363	-118.38969	Plan check for a PV2 roof-mounted PV system. System size is 35 kWac and consists of (2) inverters, (110) modules, (2) combiner boxes, and (1) load center.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41859	14041-20000-08147	3907 W GLENFELIZ BLVD	90039	13	156A207   265	5435020002	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.1215	-118.26712	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 3.36 KW DC.(14) TRINA TSM 240 MODULES(14) M215 MICROINVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41860	18041-20000-25454	5933 N ADLER AVE	91367	3	177B089   701	2045017030	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.17888	-118.64733	Plan check for the addition of a PV system onto an existing PV1 roof-mounted PV system. System addition size is 8.4 kWdc and consists of (1) 7.6 kWac rated inverter, (28) modules, (2) load centers, and (1) back-up battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41861	10041-10001-25467	540 S NORMANDIE AVE	90020	10	135B197   947	5502018002	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.06411	-118.30015	DELTA 2 REVISION TO APPROVED PLANS.  REVISION TO SERVICE ENTRANCE FEEDER TO BUILDING, RELOCATE 1600A MAIN SERVICE OCPD, AND RELOCATE CR PANEL FEEDER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41862	14041-10000-27475	13484 W BAYLISS ROAD	90049	11	138B133   397	4492013008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.07275	-118.50409	PV1, INSTALL 10.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SSERVICE PANEL.(40) MODULES: KYOCERA# JD255GX-LFB3(2) INVERTERS: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41863	17041-10000-24545	2270 E CENTURY BLVD 101-206	90002	15	091-5A217 107	6046019920	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	33.94631	-118.23133	PROPOSED 3-STORY, 10-UNIT APARTMENT BUILDING, FULLY SPRINKLERED NFPA 13.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41864	15041-10001-34775	5402 N FALLBROOK AVE	91367	3	171B097   115	2040027024	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	34.16851	-118.62308	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 10.40 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(40) MODULES: TRINA TSM-260 PA05A(1) INVERTER: FRONIUS PRIMO 8.2-A 240V>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41865	16041-20002-44967	3340 S MOTOR AVE	90034	5	120B161    80	4314023016	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.02863	-118.41004	Revisions to approved set of plans plus plan review for lost approved plan set.  Change of module brand.  (((Plan check for installation of a solar pv array, roof-mounted on a commercial building.Interconnect with a 400A MSP. 20kW (10+10) ungrounded system. (72) 280W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41866	15041-10000-34622	3109 E 12TH ST	90023	14	118-5A223  74	5169005007	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.019	-118.21297	Title 24 plan check only.  Total area = 19,291 sq. ft. (unconditioned) + 3,700 sq. ft. (outdoor)   T.I. to existing building.  Undeveloped indoor spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41867	14041-10000-24774	1545 W FRANCISCO ST	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	33.84964	-118.30593	Plan check for power and lighting. 17,825 sq ft. Change of use from warehouse to office space.Addition of 5 new panel boards with connected loads greater than 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41868	15041-10000-14903	14518 W VENTURA BLVD	91403	4	166-5A151 139	2276001004	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	34.15087	-118.4494	Plan check only. Permit has been pulled under #15041-10001-14903.Engery plan check for a retail to restaurant building (Presseat). Scope includes new lighting, equipment and receptacle outlet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41869	11041-10000-27336	4299 S CRENSHAW BLVD	90008	8	114B185  1064	5024007023	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM			PC Info Complete	11/19/2013 12:00:00 AM	ADDRESS	34.00545	-118.33406	Plan check power and energy for new 7-Eleven tenant in existing building. Main 1000A service approved under #13041-10000-16216	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41870	19041-10000-47663	23749 W FITZGERALD ST	91304	12	189B089    18	2020010034	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	07/12/2020 12:00:00 AM	ADDRESS	34.2178	-118.64551	PV1. NEW SOLAR SYSTEM ON EXISTIN RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.88KWdc / 11.029KWac.(33)MODULES- LG360Q1C-A5(1)INVERTERS- SOLAREDGED SE7600H-US(1)INVERTERS- SOLAREDGE SE3800H-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41871	13041-10000-27214	1114 E 8TH ST	90021	14	124-5A213 367	5146019007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.03501	-118.24516	13041-10000-27214permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41872	12041-10000-24440	6315 W HOLLYWOOD BLVD	90028	13	148-5A187 148	5546004014	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			Reviewed by Supervisor	10/22/2012 12:00:00 AM	ADDRESS	34.10178	-118.32731	PLAN CHECK POWER AND ENERGY FOR REMODEL OF NIGHT CLUB/LOUNGE/BAR. (MORE THAN 100  OCCUPANTS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41873	17041-20000-38035	2022 W SUNSET BLVD	90026	13	139-5A207  91	5404003035	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Apartment			10/23/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.07751	-118.2627	4 STORY 36 UNIT APT WITH SUBTERRAINIAN PKG. PC FOR POWER AND ENERGY. NON METHANE.FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41874	12041-10000-22864	108 E 5TH ST	90013	14	129A211   204	5148019010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			09/25/2012 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.04636	-118.2484	Plan check for power and energy. Add 2-stories to existing 3-story building resulting in a 5-story building.  Remodel and renovation of existing building to new mixed-use of 69-unit affordable housing development with ground floor future retail spaces. New 2000A service. (1600A supplying residential/house + 600A future retail). Modification to seperate fire alarm has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41875	15041-20000-03075	12491 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	33.97895	-118.41081	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41876	16041-20002-32269	16509 W SATICOY ST 2nd Floor	91406	6	186B137    25	2205009054	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	ADDRESS	34.20857	-118.49267	5.25.2017 - Plan check for modifications to approved set. Update plans to reflect as-built on field. Remove time clock, update lighting layout. Update T24 forms to reflect changes.======Plan check for Title 24 only. Project site is an existing commercial 2-story building. Project scope is a tenant improvement to the 2nd floor. Total lighting area = 2,875 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41877	11041-10000-20299	19648 W SHERMAN WAY	91335	3	183B117    61	2130001083	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	PIN	34.20072845	-118.56141932	TI IN AN EXISTING COMMERCIAL SPACE  (7/11 STORE).   PLAN CHECK IS FOR T-24 ENERGY CALCS. PERMIT WAS ISSUED ===> 11041-10001-20299	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41878	17041-20000-07879	17270 W DEVONSHIRE ST	91325	12	204B133   195	2694015006	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.2574	-118.51061	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41879	18041-10000-06882	6255 W SUNSET BLVD SUITE#1110	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	PC for T24 only for lighting in office areas in high rise building. Installing new lights, receptacles and equipment. Total area is 2973sqft. B# 18016-10000-02242.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41880	16041-10001-40178	713 N CYPRESS AVE 713, 715,	90065	1	145-5A219 393	5453020024	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	34.09131	-118.22349	PC FOR T24 ENERGY ONLY FOR PERMIT ALREADY ISSUED. NEW LIGHTING AND POWER UPGRADES FOR TI. RESTAURANT SPACE AND OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41881	12041-20000-13169	14650 W SHERMAN WAY	91405	6	183B149   112	2219007027	R5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.20013	-118.45208	Install emergency lighting in all corridors of the high rise building.  Plan check for energy.  Emergency lighting are supplied from existing generator.  All panels, breakers and wiring are existing	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41882	16041-30000-28583	2029 S CENTURY PARK EAST 11th FL-Lobby	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Issued	08/11/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in elevator lobby 11th floor in existing high-rise. Total lighting area: 340 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41883	19041-20000-32295	8414 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41884	13041-20000-32558	7927 N VAN NUYS BLVD	91402	6	189B149   392	2210022056	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.21503	-118.449	T24 FOR REMODEL TO CREATE SEARS HOME APPLIANCE SHOWROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41885	12041-20000-28752	3023 S WESTERN AVE	90018	10	120B193   522	5053006903	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	Apartment			11/29/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.02667	-118.30906	FIre alarm for apartment building. Jefferson Park Terrace	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41886	16041-10003-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	PC FOR CHANGES TO APPROVED SET UNDER DELTA 16. SCOPE INCLUDES NEW CIRCUIT AND 2 NEW RECEPTACLES WHERE INDICATED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41887	19041-30000-25469	2049 S CENTURY PARK EAST 37th FLoor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	ENERGY PC FOR T. I. RENOVATION TO PUBLIC Restroom.  AREA 410SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41888	16041-10000-11328	6101 N SHIRLEY AVE	91356	3	177B117   512	2153028032	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Expired	05/02/2018 12:00:00 AM	ADDRESS	34.18105	-118.55804	PV1 roof mounted solar system installation system to a single family home, interconnected to the main house panel using an inverter and optimizers. 10.0 kw inverter, 41 solar modueles. Total system size is 10kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41889	11041-20000-17096	14000 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	11/18/2011 12:00:00 AM	ADDRESS	34.15735	-118.43783	Ti in an existing restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41890	19041-10000-16912	2429 N NOTTINGHAM AVE	90027	4	153B193   290	5588003017	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.11304	-118.3017	Permit fee is $0.00 due to AB1414PV1. SYSTEM SIZE OF 11.2575 KWDC AND 11.4 KWAC WITH (474) TESLA MODULES, (2) 7.6  AND 3.8 KW TL INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41891	12041-10000-16118	12852 W RUNWAY ROAD	90094	11	102B157   392	4211033033	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	33.97543	-118.41892	New 2-story community center w/ exercise rooms, meeting rooms, classrooms, and pool deck.  Full Plan Check for Power and Energy.  Site is in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41892	12041-10000-27019	3526 S STONER AVE	90066	11	114B157    66	4249017010	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Expired	12/03/2014 12:00:00 AM	ADDRESS	34.0122	-118.43161	PV1 2.45 KW ROOF-MOUNT. ENPHASE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41893	15041-10000-24072	1500 W PACIFIC COAST HWY Bldg K	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 20 unit apartment with garage, 53 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41894	17041-10001-13157	8133 W ELLENBOGEN ST	91040	7	210B193   225	2551018053	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.2721	-118.31065	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling.  Two inverter system.  Total system size = 15 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41895	19041-10000-53716	1148 W MANCHESTER AVE	90044	8	097-5A197 344	6047003011	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Info Complete	12/30/2019 12:00:00 AM	ADDRESS	33.95984	-118.29553	PLAN CHECK FOR A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, AND CONTROLS USING EXISTING CIRCUITS. TOTAL AFFECTED AREA IS 5482 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41896	14041-10000-34731	8556 S EMERSON AVE UNIT 11	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	01/30/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 11 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41897	16041-10009-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	05/10/2021 12:00:00 AM	ADDRESS	34.04771	-118.46271	Change to approved set by adding new circuits and updating the power plan and lighting plan. All changes under delta 19 and A22.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41898	14041-10000-12635	20822 S DALTON AVE	90501	15	054B193   492	7351024025	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Expired	07/08/2016 12:00:00 AM	ADDRESS	33.84124	-118.30269	PV1, INSTALL 3.57 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER. TRANSFORMERLESS INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41899	19041-20000-39105	6444 N BELLINGHAM AVE	91606	2	180B165   614	2322006040	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.18806	-118.3986	T24 PLAN CHECK ONLY FOR TI FOR A CHANGE OF USE FROM RETAIL TO BEAUTY SCHOOL. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 4746 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41900	15041-20001-09668	835 W 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	PIN	34.02383917	-118.28572873	[[[[6/29/15 CHANGES TO APPROVED SET, TITLE 24 ENERGY. ADDITION OF OFFICE ]]]PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT - REMODEL OF MENS AND WOMENS RESTROOMS ON FIRST FLOOR FOR UNIVERCITY RELIGIOUS CENTER IN USC.  (61 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41901	12041-20000-27847	725 S FIGUEROA ST 20th floor	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	T.I.  Existing office space (20th floor).  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41902	17041-10000-44539	2037 S GRANVILLE AVE	90025	11	123B149   342	4262033015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Issued	12/12/2017 12:00:00 AM	ADDRESS	34.03493	-118.45158	Remove HID fixtures and replace with new LED fixtures  T-24 only.TOTAL SQ.FT 13050	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41903	16041-30000-07642	600 WORLD WAY Space 634	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	03-03-16 Changs to approved set of plans. Changes include remove lighting fixtures, removed 4 circuits in panel LA and combine some receptacle to same circuit on the floor plan. Changes apply to delta 9 only. Note: This plan check refer to approved set of plan Application Number: 15041-20001-22789****************Previous work description****************************Changes made to approved plans - change of lighting fixtures and panel size.  (((Title 24 plan check only.  Total area = 1,310 sq. ft.  T.I. to existing commercial space.  New 400 A panel to provide power.  Upgrading 845 sq. ft. walk in cooler as well.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41904	12041-20000-01168	11726 W SAN VICENTE BLVD 2nd,4th,5t-h elev lob	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM	01/18/2012 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.05328	-118.46625	energyb plan che 2nd 4th and 5th floor elevator lobby	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41905	18041-10000-15479	7865 W SUNSET BLVD	90046	4	147B177   975	5551019021	C4-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.09823	-118.36113	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41906	14041-10000-01748	944 E SLAUSON AVE	90001	9	108B209  1586	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	33.98915	-118.25799	Install new fire alarm system for a one story grocery store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41907	19041-10000-20423	580 N PASEO MIRAMAR	90272	11	129B117    65	4416019059	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.04695	-118.55707	No Permit Fee due to AB1414PV1 for a roof mounted system system size is 13.33 KWdc/11.4 KWac.  Scope of work is 43 modules with optimizers ( P320) , 2 inverters (SE3800 H-US, and SE7600A-US), 1 battery (LG RESU10H 9.8 KW) , One new load center rated at 100 A, 1 new transfer switch and a new subpanel rated at 125 A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41908	11041-10000-18598	1545 W WILSHIRE BLVD 4TH FL	90017	1	132A205   202	5142027036	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	34.05543	-118.26977	INSTALLATIONAL OF OPTIONAL STAND BY GENERATOR AND ATS  AND 40KVA UPS WITH ASSOCIATED PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41909	11041-10000-10162	316 E 111TH ST	90061	15	088-5A205 293	6073019902	PF-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	33.9347	-118.26884	TENANT IMPROVEMENT ON 2ND FLOOR.   CHANGE OF USE FROM OFFICE SPACE TO CLINIC AND MENTAL HEALTH FACILITY.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41910	12041-10000-00995	2101 E PACIFIC COAST HWY HTU2	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			Corrections Issued	01/29/2012 12:00:00 AM	ADDRESS	33.79173	-118.23549	New Analyzer Enclosure (for anyalyzing emissions) at the Tesoro Oil Refinery.  (Hazardous classified area).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41911	17041-10000-20957	180 S LA BREA AVE	90036	5	138B181  1246	5513018017	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.07124	-118.34383	Plan check for power and Title 24.  T.I. to existing restaurant.  New 800 amp switchgear with one 400 amp breaker feeding tenant space and one 400 amp breaker feedeng neighboring tenant.  Two new subpanels with lighting, receptacle, and HVAC loads.  Lighting area = 2,460 sq. ft. (indoor) + 85 sq. ft. (outdoor)       Building permit #17016-10000-16779	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41912	12041-20000-19261	972 N LA CIENEGA BLVD	90069	5	144B173   209	5529006042	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM			PC Approved	08/16/2012 12:00:00 AM	ADDRESS	34.08862	-118.37622	Install new general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41913	17041-30000-10232	8460 N HATILLO AVE	91306	3	192B113   268	2782006014	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.22381	-118.56544	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41914	17041-10000-45545	207 1/2 N LAKE SHORE TER	90026	13	135A207   195	5159017009	R3-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.06462	-118.26119	PC for 3.8 kW roofmounted solar PV.  Installing 5 modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41915	16041-20001-36990	18711 W SHERMAN WAY	91335	3	183B121   100	2118026019	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.20128	-118.54074	changes to an approved set of plans.  changes include new lighting and revisions to energy calculations.  this is plan check only.office energy and power plan check retail for future just temp lighting in multiuse building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41916	15041-10000-19929	4658 N ATOLL AVE PV1	91423	4	168B157   546	2360024010	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.15559	-118.42015	PV 1INSTALL ROOF MOUNTED PV SYSTEM. SIZE 8.8 KW INTERCONNECTED WITH MAIN SERVICE PANEL. (29) LG MODULES, MODEL LG 300 AC-B3, (29) LG INVERTER LM305UE-G1. PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-10000-15405.Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. INSTALLATION OF A PV SYSTEM 24 PV MODULES 7.2 KW DCThe solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41917	18041-10000-09036	7630 N ALABAMA AVE # 2	91304	3	186B105    81	2110017***	MR1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.20928	-118.59921	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41918	18041-10000-27603	19270 S WESTERN AVE	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.85733	-118.30917	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41919	12041-40000-23787	1515 N SAN FERNANDO ROAD 1-87	90031	1	147A217   364	5442002908	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			10/04/2012 12:00:00 AM	05/03/2013 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.09631	-118.23259	Construct 87-unit apartment building (86 restricted affordable residential units for households earning up to a max 60% AMI plus one non-restricted manager unit) -	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41920	14041-10000-08654	6940 ESTEPA DR	91042	7	198B201   177	2572042004	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	PIN	34.24095021	-118.28301165	PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(18) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41921	14041-20000-13522	13135 MIRA MAR DR	91342	7	225B165    19	2580018***		North Valley				1061.12	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	PIN	34.31120672	-118.40409465	PV1.  Install 7 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41922	15041-20000-06965	15350 W SHERMAN WAY	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.20099	-118.46808	Title 24 plan check only.  Total area = 9,310 sq. ft.T.I. to existing low rise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41923	19041-10000-20176	9624 N GOTHIC AVE	91343	12	201B137   794	2677010011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.24527	-118.49076	PV1, PC FOR NEW ROOFTOP 5 KW AC/ 5.4 KW DC SYSTEM. SYSTEM CONSISTS OF (1) INVERTER, (18) MODULES AND OPTIMIZERS INTERCONNECTING THROGH THE SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41924	16041-10000-15354	9132 N SEPULVEDA BLVD	91343	7	198B145   337	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.2368	-118.46732	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (SKECHERS SHOE STORE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 11247 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41925	17041-20000-28708	3464 W ROWENA AVE	90027	4	153A201   298	5591003007	R1-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.1118	-118.28176	Plan check for solar pv system, roof-mounted on SFD.4.48kW ungrounded system. (14) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41926	16041-10000-10966	1875 CENTURY PARK EAST suite 370	90067	5	132B161    30	4319002060		West Los Angeles				2679.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	PIN	34.06023085	-118.41463477	T-24, TI TO SUITE 370. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1073.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41927	15041-20000-29068	4952 N RUBIO AVE	91436	5	171B137   506	2259017031	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Refund in Progress	08/31/2016 12:00:00 AM	ADDRESS	34.16089	-118.49411	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel.(22) Kyocera KU 2656 Moudles(1) PVI-5000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41928	12041-20000-07879	5855 N LANKERSHIM BLVD	91601	2	174B169    12	2338016011	[T][Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Info Complete	04/05/2012 12:00:00 AM	ADDRESS	34.17719	-118.3823	"Install new general/emergency lights in the addition rooms.  New added load approximately 50A.  Plan check for energy only.Note: Permit issued under 12041-20000-07883""COMPLY WITH DEPARTMENT ORDER effective date01/05/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41929	14041-10000-28947	10979 W BLUFFSIDE DR BLDG 5	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	Note to plan check engineer, applicant returns and swaps in a new plan with additional circuits added on after original fee was paid. Plan check engineer needs to verify fee with all new changes. Per F.Y.(((Installing new washer/dryers and booster fans in apartment units.  Bldg 5 of 6.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41930	17041-10000-03444	1715 N WHITLEY AVE	90028	13	148-5A185 116	5547004001	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.10207	-118.33353	PC for outdoor title 24. Removing HID fixtures and replacing with new LED ones. Area: 4560 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41931	16041-20001-04524	10031 N DONNA AVE	91324	12	204B121   483	2729004007	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.25295	-118.5483	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 19 kWac and consists of (2) inverters, (62) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41932	19041-20000-05486	7607 1/2 S MAIN ST	90003	9	099B201   134	6031013012	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	06/18/2021 12:00:00 AM	ADDRESS	33.97057	-118.27418	PV2. INSTALL 15.860 KW DC/12.48 SYSTEM PV WITH (52) PV MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41933	14041-10000-21987	8901 S METTLER ST	90003	9	096A207   231	6041025008	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Expired	11/01/2016 12:00:00 AM	ADDRESS	33.95544	-118.26663	PV1, INSTALL 1.785 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(7) MODULES: KYOCERA KD 255GX(1) INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41934	17041-20001-18634	5060 N AMESTOY AVE	91316	5	171B133   648	2258014006	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			PC Approved	08/21/2017 12:00:00 AM	ADDRESS	34.16199	-118.50531	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv array, with DC coupled battery backup system.6kW ungrounded inverter system. 5kW battery backup. (16) 315 pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41935	16041-10000-33726	2800 W OLYMPIC BLVD	90006	10	129B197   235	5078013028	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.05242	-118.2951	Lost plans on  15041-10000-04941 and 10001 is PC infor complete for a 70 unit apartment. ********************************************Plan check for power and energy for new mixed-use apartment building with 4 stories apartment dwelling units. 69 unit apartment with 2500A-rated 208Y/120 service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41936	15041-10001-41798	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.08901	-118.34188	Changes to approved set of plans. Changes to hvac and fault current from utility. Updated AIC ratings, service load calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41937	19041-10000-45725	2410 N LILLYVALE AVE	90032	14	139-5A237 104	5220034025	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	08/05/2021 12:00:00 AM	ADDRESS	34.07504	-118.16432	"PLAN CHECK FOR POWER & ENERGY - INSTALLING A NEW 250KVA (200KW) GENERATOR, PANELS, LOADS, 2 @ 50KW UPS, TRANSFORMER, LIGHTS, ETC. (((BULDING PERMIT: 19010-10000-04950 ---- SINGLE NEW BUILDING-CONSTRUCTION ADDED ONTO TRACT 34415, PARCEL LOT #3, OF THE ""FRIFOLS"" MULTI-BUILDING SITE. OCCUPANCY: DATA CENTER FOR COMPUTER EQUIPMENT AND POWER WITH REDUNDANT BACKUP. CONSTRUCTION: CONCRETE MACONRY BEARING, CONC. ROOF SLABS ON STEEL DECK.))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41938	11041-10000-27676	2151 S AVENUE OF THE STARS 1st Fl	90067	5	132B161   193	4315019006	R4-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.05439	-118.41225	T.I. to existing building on 1st floor.  Intall general/emergency lighting in restroom, office, storage, and prefunction hotel area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41939	19041-10000-14090	10755 W VENICE BLVD	90034	5	117B161   489	4252030041	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.01813	-118.40851	Replace fluorescent troffers with new LED retrofit kits, Indoor only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41940	16041-10001-41796	10250 W SANTA MONICA BLVD #S1860-Storage	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time tenant ""Bacio di LAtte"" REMOTE STORAGE.  new panel and its circuits, total effected area: 347 sq.ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41941	17041-10000-12862	20549 W DEVONSHIRE ST	91311	12	204B109   127	2707013030	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			PC Info Complete	05/25/2017 12:00:00 AM	ADDRESS	34.25742	-118.58102	PC FOR T24 ENERGY ONLY. NEW PRIVATE SCHOOL. GROUP E OCCUPANCY. UPGRADED LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41942	12041-10001-30390	5900 W WILSHIRE BLVD 11 floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	(((CHANGES MADE TO PREVIOUSLY APPROVED PLANS. F-10'S CHANGED TO F-14'S IN THE ELEVATOR LOBBY. F-2'S CHANGED FROM T5 TO T8. F-3 CHANGED FROM FLUORESCENT TO LED))))T24. TI TO EXISTING OFFICE. HIRISE 11TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41943	18041-10000-25937	2930 E WHITTIER BLVD	90023	14	123A223   253	5189004053	C1-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	02/13/2020 12:00:00 AM		Permit Finaled	05/14/2021 12:00:00 AM	ADDRESS	34.03069	-118.20803	PC POWER ONLY FOR A NEW 130KW GAS GENERATOR ON ROOF OF AN EXISTING T-MOBILE STORE.  SCOPE INCLUDES A NEW 800A  ATS AND NEW FEEDERS.B#18016-10000-14801	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41944	18041-10000-01629	5630 N FAIR AVE	91601	2	174B173   803	2337031009	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Apartment			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.17311	-118.37446	NEW FIRE ALARM SYSTEM ON THREE STORY + ROOFTOP (TOTAL 15 UNITS) APARTMENT BUILDING OVER ONE LEVEL OF OPEN PARKING GARAGE. (2) FA PANELS, (78) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41945	17041-20002-01333	10244 N WOODLEY AVE	91343	12	204B141   390	2669007018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	34.25673	-118.48466	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (48) modules, (24) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41946	17041-20000-23853	6560 W FOUNTAIN AVE	90028	4	144B185   157	5533001004	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			07/14/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.09412	-118.33247	New 5-unit 2-story apartment building.  600A 240/120V single phase service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41947	18041-10000-32938	14901 W OXNARD ST	91411	6	177A149   108	2242027021	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Info Complete	05/14/2019 12:00:00 AM	ADDRESS	34.17954	-118.45778	"NEW SERVICE UPGRADE to 600 AMP- ALL NORMAL AND EMERGENCY LIGHTS ARE EXISTING TO REMAIN.  NO NEW LIGHINGS ARE INSTALLED. EXISTING OFFICE AREA. THIS PERMIT IS NOT FOR A ""GROW HOUSE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41948	19041-20001-01438	10722 N BELMAR AVE	91326	12	207B117   194	2708006030	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.26516	-118.55893	expeditepv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41949	17041-30000-26621	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			08/03/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	33.95637	-118.3838	Plan check for a  new fire system for 61 units appartment 4 story. Scope includes  (259) devices,  (4) control panels and  (1) FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41950	16041-10000-19865	330 N CLIFFWOOD AVE	90049	11	135B137   658	4405012006	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM			PC Info Complete	08/12/2016 12:00:00 AM	ADDRESS	34.06203	-118.48686	PC FOR POWER ONLY FOR A NEW 2 STORY DWELLING AND ATTACHED GARAGE WITH HABITABLE BASEMENT. SCOPE INCLUDES A  NEW 120/240V 1PH, 3 WIRE SERVICE/MAIN DISTRIBUTION BOARD, AND NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41951	13041-10000-25654	6255 W SUNSET BLVD STE 1112	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	TITLE-24 FOR OFFICES IN A HIGH-RISE BUILDING. EMERGENCY LIGHTS WILL BE FED FROM GENERATOR EXISTING EMERGENCY CKTS. TOTAL AREA IS 1164.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41952	11041-10001-09788	14530 W NORDHOFF ST	91402	6	195B149    18	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.23519	-118.44861	PLAN CHECK ONLY FOR REVISION #6 TO APPROVED PLANS. REVISIONS TO LIGHTING AND POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41953	19041-20001-06550	2439 N RIVERSIDE PL	90039	13	148-5A211 150	5440026008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM			Reviewed by Supervisor	03/06/2019 12:00:00 AM	ADDRESS	34.10129	-118.25338	NEW 7.315 KW DC/7.6 KW AC ROOFTOP PV SYSTEM AND ESS FOR EXISTING SFD, SCOPE OF WORK INCLUDES (1) 7.6KW AC SOLIVIA INVERTER, (308) TESLA PV MODULES, (1) NEW 125A LOAD CENTER, (1) NEW 200A LOAD CENTER, AND (1) 13.5 KW TESLA POWERWALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41954	13041-20000-00092	10349 N JOVITA AVE	91311	12	204B113    88	2707015029	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.2588	-118.57662	Roof mounted PV system on roof of single family dwelling using two transformerless inverters with PV load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41955	10041-10000-10623	6636 W SELMA AVE	90028	13	148-5A185 380	5547019028	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM			PC Info Complete	01/20/2011 12:00:00 AM	ADDRESS	34.09959	-118.33446	CHANGE OF USE FROM A CONVENT TO A SOCIAL SERVICES CENTER :NEW SERVICE, PANEL AND CIRCUITS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41956	14041-10006-27847	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	"5/3/2016Change to the approved set of plan. changes includes relocation of temporary loads and 1600A distribution board(3ldsk). the loads connecting to existing 600A panel. All changes noted delta 6 revision on plans02/11/2016Changes To an approved set of plans. Changes include the connection of temporary load. The loads connecting to ""MS2"" are in (E) panels ""EDS"", ""DSBG"" and DSBG-A"". 8/12/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  TEMPORARY POWER FOR BAGGAGE HANDLING.7/24/2015 PLAN CHECK FOR CHANGES TO SET OF PLANS DELTA 1 AND DELTA 2. RESHUFFLING OF LOADS AND RELOCATION OF PANELS. NO NEW LOADS HAVE BEEN ADDED. ((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX TERMINAL 1. CHANGING OF THE POWER DISTRIBUITION SYSTEM AND LIGHTING.))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41957	15041-10000-27121	1001 N DOYLE PL 1-2	90012	1	136-5A215 112	5414017031	R3-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.06764	-118.23693	New methane detection system, level 4. bldg 2 of 2, retail space, 7 devices, 1 control panel. Plans start at sheet VC 12 per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41958	17041-10001-36040	7843 N LANKERSHIM BLVD SUITE #101	91605	6	189B169   517	2310025***	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	Changes to an approved set in a first time occupancy in a new clinic. Scope includes addition of the panels relocated from Service Pavillion plans (E# 18041-10001-20327) to the single line of this plan. RTI final permit fees are not paid under the original application 17041-10000-36040.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41959	10041-10000-22893	5890 W JEFFERSON BLVD # B	90016	10	120B173   380	4205027011	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM			Corrections Issued	11/16/2010 12:00:00 AM	ADDRESS	34.02226	-118.3768	CHANGE OF USE FROM AN OFFICE TO A TAKE-OUT RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41960	18041-10000-08616	121 E WINDWARD AVE	90291	11	108A143   434	4238014006	C4-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	33.98815	-118.47182	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41961	18041-10000-12046	2335 S CRENSHAW BLVD #1-7	90016	10	123B185   223	5061022047	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			Reviewed by Supervisor	05/10/2018 12:00:00 AM	ADDRESS	34.03615	-118.33344	PC for power and energy for three story 7 unit apartment wtih parking garage. Installing new 600A service, seven unit panels and new house panel. (T24 forms for parking space to be submitted as correction) B#18010-20000-00116. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41962	14041-10000-33120	6381 W HOLLYWOOD BLVD	90028	13	148-5A187 157	5546005010	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.10177	-118.32913	Full plan check for an assembly  to a change of use from bank to night club. Total area 7125 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41963	17041-10000-13640	12501 W TRUESDALE ST TEMP	91352	6	198B165   199	2629004902	OS-1XL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Issued	04/26/2017 12:00:00 AM	ADDRESS	34.23644	-118.40516	PC AND PERMIT FOR TEMP POWER 600A FOR CONVEYORS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41964	15041-20000-10136	2245 W YOSEMITE DR BUILDING B	90041	14	160-5A221  43	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.13556	-118.21671	"Plan check for power  and energy only. Work being done on Building ""B"". Removal of existing multiple services and adding a new 2500A service. 4210 sqft outdoor."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41965	12041-10001-21885	6041 W CADILLAC AVE	90034	10	126B173   862	5066002026	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.03806	-118.37594	Plan check for T24 for an exam room, Emergecy lights are existing to remain. Plan check for power was done under separate application # 12041-10000-21885. (((((((((((((((((((((Plan check power exam rooms TI on the third floor.  Kaiser medical office building. New panel, branch circuits.  Plan check for power only. Note:  Energy plan check under a separate application.))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41966	16041-10000-26536	11600 W TUXFORD ST	91352	6	192B169   306	2632023046	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Issued	12/28/2016 12:00:00 AM	ADDRESS	34.22447	-118.38481	Plan check for power only.  Service upgrade to 800A, 120/240 V, 3ph, 4W. Submitted per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41967	14041-20000-11520	10727 N OVERMAN AVE	91311	12	207B109   189	2707004029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.2659	-118.57797	Roof mounted PV system with transformerless inverter.  PV system size is 11.75KWdc.Note: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41968	18041-20000-47360	555 S MATEO ST 2ND FLOOR	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	01/02/2020 12:00:00 AM		Permit Closed	10/25/2020 12:00:00 AM	ADDRESS	34.03943	-118.23302	First time tenant to second floor commercial office space.  25,750 sq ft.  Plan check for power and energy.  Associated building permit under 18016-10000-39842.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41969	15041-20000-02033	13126 W BASSETT ST	91605	2	183B161   756	2327007146	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/28/2015 12:00:00 AM	ADDRESS	34.1957	-118.41907	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.0KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41970	18041-10001-09703	2221 W BERKELEY AVE	90026	13	142-5A207 233	5423010013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.08442	-118.2617	PC FOR CHANGES TO APPROVED SET TO REFLECT CORRECT SERVICE LAYOUT (MSP FROM SINGLE FAMILY TO DUPLEX - 2 GANG).NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 17 MODULES (EAGLE PERC60 290w), OPTIMIZERS (SOLAR EDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE5000A-US). SYSTEM SIZE IS 5KWac AND 5.44KWdc.THIS IS PLAN CHECK ONLY!PERMIT PAID UNDER 18041-10000-10465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41971	16041-10000-42198	1233 N HIGHLAND AVE	90038	4	144B185   292	5532006029	C2-1D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	04/14/2021 12:00:00 AM		Issued	04/14/2021 12:00:00 AM	ADDRESS	34.09349	-118.33882	PC FOR ENERGY AND POWER. 76 UNITS 6-STORY  MIXED USED APARTMENT BUILDING. ONE GROUND LEVEL, AND 2 UNDERGROUND LEVEL PARKING. 22 TYPICAL UNITS. ONE 4000 A SERVICE. TOTAL AREA  110844 SQ FT. FIRE ALARM TO BE FILED SEPERATELY.B# 16010-10000-05437	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41972	18041-10000-18301	2029 S CENTURY PARK EAST 2300	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TENANT IMPROVEMENT IN AN EXISTING OFFICE AREA ON THE 23RD FLOOR IN SUITE #2300.PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
41973	19041-10000-47832	10608 N VALJEAN AVE	91344	12	207B137   578	2679019004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.26294	-118.48681	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 25  (PANASONIC GROUP) MODULES, 25  (SOLAREDGE P400) OPTIMIZERS, 1 (SE7600A-USS) CENTRAL INVERTER, 1 LG CHEM BATTERY, CONNECTED TO A NEW 125A PANEL. SYSTEM SIZE IS 8.125KW DC & 7.60KW AC. MAIN PANEL UPGRADE UNDER SEPARATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41974	13041-10000-19131	101 S LA BREA AVE #100A	90036	5	138B181   871	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.07338	-118.34425	Plan check power and energy for first time tenant - Sugarfish Restaurant (suite #100A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41975	12041-10000-25835	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.0754	-118.38272	PLAN CHECK POWER AND ENERGY FOR T. I. OF EXISTING MEDICAL RESEARCH LABORATORIES   ON THE FIRST & THIRD FLOORS. NEW PANEL BOARD, LIGHTING,  CIRCUITS, AND ELECTRICAL DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41976	18041-10001-24338	9005 W EXPOSITION BLVD	90034	5	120B169    49	4312013029	M1-1	West Los Angeles	West Los Angeles	South Robertson		2701.00	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	09/08/2022 12:00:00 AM	ADDRESS	34.02864	-118.3922	CHANGES TO APPROVED SET, SCOPE OF WORK IS GOING FROM A SPLIT BUS SYSTEM, TO SERPARTE PANELS FOR DESEGRAGATION PURPOSES, NO NEW LOAD WERE ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41977	14041-10004-30557	1099 S GRAND AVE	90015	14	127-5A207 265	5139008001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Closed	09/18/2015 12:00:00 AM	ADDRESS	34.04179	-118.26214	Modifications to approved set.  Changes to match current site conditions - additional 35 HP manlift, removal of temp panel RP1, removal of (2) 100 HP elevator motors, and spare breakers now indicated.  (((Temp power for existing building renovation.  Plan check for power.  Initial permit filed under 14041-10000-28931.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41978	19041-10000-50917	737 S STANFORD AVE	90021	14	126A213   570	5146031046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	03/02/2020 12:00:00 AM		Issued	03/02/2020 12:00:00 AM	ADDRESS	34.03822	-118.24547	PLAN CHECK FOR POWER AND ENERGY. 600A SERVICE, 120/240V, 3 PHASE. SCOPE OF WORK INCLUDES 4 NEW PANELBOARDS. TOTAL EFFECTED AREA IS 7196 SQAURE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41979	14041-20001-20082	1433 N SUMMITRIDGE DR	90210	5	147B157   388	4355005030	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM			PC Approved	08/04/2014 12:00:00 AM	ADDRESS	34.09654	-118.42012	Expedite per customer request(((14.3KW PV1 roof-mounted system with (1) 100Amp load center, (2) Solaredge SE6000 inverters, (55) Rec Solar REC260 and Solaredge P300 power optimizers.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41980	15041-20000-18171	1100 S GLENDON AVE # 100	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.06074	-118.44418	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 6,203 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41981	11041-20000-23687	7370 W SUNSET BLVD	90046	4	147B181   654	5550021001	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.09785	-118.35128	Plan check power and energy for existing hotel building. Upgrading service to 1000A, new panels, equipment, ckts, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41982	19041-10000-20344	3710 S MCCLINTOCK AVE 4TH FL	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.02027	-118.28994	Energy plan check for an office T.I located in the 4th floor of a commercial building. Scope includes new glass wall and equipment with a total lighting area of 600-SQ FT. Note: No new lighting added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41983	19041-10000-02337	333 S GRAND AVE ste 1911	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLAN CHECK FOR T24 ONLY, INTERIOR OFFICE TI TO CREATE EMPLOYEE BREAKROOM/CATERING AREA  (PORTION OF 19TH FLOOR), NEW CONNECTED POWER < 200A , AND ARE FED FROM EXISTING PANEL BOARDS. TOTAL AREA: 9054 SQ.FT   (B# 18016-10000-37590)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41984	10041-10000-01483	16101 W VENTURA BLVD	91436	5	168B141   539	2260023057	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM			PC Approved	01/29/2010 12:00:00 AM	ADDRESS	34.15658	-118.48382	REMODEL YOGURT SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41985	18041-20002-42732	238 S LUCERNE BLVD	90004	4	135B189    73	5515021007	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.0699	-118.32465	PLAN CHECK ONLY. CHANGES TO APPROVED SET. CHANGES TO SINGLE LINE AND RELOCATION OF ESS TO BASEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41986	14041-20000-23094	5055 W WILSHIRE BLVD # 840	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.06235	-118.34036	TI, SUITE 840. NEW LIGHTING. PLAN CHECK FOR ENERGY ONLY. DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41987	16041-20000-10540	6555 W BARTON AVE 5th Floor	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.08785	-118.33475	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the 5th floor corridor. Total lighting area = 1,700 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41988	19041-10000-25330	10532 N VARIEL AVE	91311	12	207B105   442	2706018036	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.26181	-118.59279	[EPLAN]PLAN CHECK FOR 10.6KVA (9.72 kW DC) PV1 SYSTEM  CONSISTING OF 2 CENTRAL INVERTERS(SE7600H-US & SE3000H-US) WITH 27 MODULES USING P400 OPTIMIZERS  AND 1 ESS(TESLA POWER WALL) CONNETED TO NEW 225A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
41989	12041-20000-00121	8366 N FULLBRIGHT AVE	91306	12	192B113   390	2781021014	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.22235	-118.57624	Enphase M215 inverter PV system on roof of single family dwelling.  A variance to use un approved equipment was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41990	18041-10000-41703	6527 W COLGATE AVE	90048	5	135B173    54	5511042007	R1-1-O-RFA	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.06995	-118.36837	Plan check for a PV1 3.3KW AC roof-mounted system. Scopes includes (9) modules, (1) inverter, and (1) Energy storage system (power supply) interconnecting through the subpanel. Note. Portion of the permit fee is paid under 18041-90000-39440.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41991	17041-20001-00958	9010 N FORBES AVE	91343	12	195B133    73	2688025039	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2017 12:00:00 AM			PC Approved	02/03/2017 12:00:00 AM	ADDRESS	34.23422	-118.4998	Expedited per applicant request.Plan check for an addition of a PV1 roof-mounted PV system onto an existing PV system. System addition size is 11 kWac for a total system size of  12 kWac. Additon consists of (51) modules, (51) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41992	12041-20000-01068	350 S GRAND AVE 23rd fl.	90013	9	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	PIN	34.05160512	-118.25169569	Permite for TI in a commercial BLDG. (EPC was for Energy) Ford  & Harrison BLDG. Fire/ life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41993	15041-10000-03147	725 S FIGUEROA ST Suite 2050	90017	14	129A207   336	4226001902	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Expired	05/08/2021 12:00:00 AM	ADDRESS	34.04886	-118.26071	Title 24 plan check only.  Total area = 2,636 sq. ft.T.I. to existing commercial space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41994	13041-20000-32107	149 N GRAMERCY PL	90004	4	138B193   808	5516018001	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.0744	-118.31262	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 1.72KWAC. 8 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
41995	18041-10000-19522	12683 N GLENOAKS BLVD	91342	7	219B153    17	2508027013	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.30049	-118.4409	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41996	19041-10000-08685	5807 S AVALON BLVD	90011	9	108B205  1107	5101006005	MR1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.10	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	33.98959	-118.26538	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41997	17041-10000-22105	236 S LOS ANGELES ST BLDG B-UNIT H	90012	14	129A213    65	5161024006	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.04922	-118.24386	PLAN CHECK FOR T24 ONLY FOR TI (Change of use a portion of retail space to veterinary clinic (Non-bearing partition) TOTAL AFFECTED AREA = 2215 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
41998	16041-20000-02007	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	33.87528	-118.29083	Chiller and cooling tower replacement in existing 5 story commercial building. Plan check for power and energy. Total sqft. 2,767.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
41999	14041-10000-23883	10844 W LINDBROOK DR	90024	5	132B153   242	4360003028	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.06013	-118.44228	New fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42000	11041-10000-13996	7224 W MULHOLLAND DR	90068	4	156A181   646	5572001004	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1437.00, 1941.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.12011	-118.34848	NEW 8.9KW PV SYSTEM FOR A SINGLE FAMILY RESIDENCE.  PLAN CHECK IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42001	13041-20000-17759	10810 W PALMS BLVD	90034	5	120B161  1013	4252037033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.02	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.02312	-118.41412	pv2 multifamily dwelling. total system size 16.5 kw. using 66 modules and 2 central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42002	16041-20001-26737	888 S FIGUEROA ST STE#1700	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.0465	-118.26225	Revisions to approved set.  Changes to lighting design.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42003	14041-10000-13451	14610 W CHASE ST D-09	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM			PC Info Complete	05/20/2014 12:00:00 AM	ADDRESS	34.22458	-118.45089	TENANT IMPROVEMENT WORK FOR NEW PANDA EXPRESS RESTAURANT; FIRST IN TENANT SPACE; NO STRUCTURAL ALTERATIONS, change of use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42004	16041-10001-22166	301 W OLYMPIC BLVD STE A	90015	14	127-5A209 229	5139004026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.04182	-118.25852	PC FOR POWER AND ENERGY. T.I. FOR CHIPOTLE MEXICAN GRILL RESTAURANT IN NEWLY CONSTRUCTED AND PREVIOUSLY UNOCCUPIED SPACE.MZ   (         2-23-17         delta 5  is changing  two ac units to 1   from trane to carreier   )                                     B# 16016-10000-14619	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42005	18041-20000-21213	7253 N MURIETTA AVE	91405	2	186B153   716	2216002057	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.20283	-118.4391	PLAN CHECK FOR BATTERY BACKUP SYSTEM(9.8W LG CHEM BATTERY) ONLY  CONNECTING TO EXISTING PV	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42006	14041-20001-22559	18208 W HERBOLD ST	91325	12	201B125   392	2764017063	RE9-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.24491	-118.52992	expedite feespv1 single family. 8.4 kw AC using 2 transformerless inverters nonstandard plan. 26 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42007	16041-10000-35353	6750 N DE SOTO AVE	91303	3	180B109    39	2148006023	C1.5-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Issued	11/03/2016 12:00:00 AM	ADDRESS	34.19316	-118.58808	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALD'S RESTAURANT. SCOPE INCLUDES ADDING NEW OUTDOOR LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42008	14041-20000-00767	3304 W BELLEVUE AVE	90026	13	141A201   380	5401013017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.07875	-118.2804	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42009	12041-10000-25996	380 WORLD WAY SPACE 5C2-10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	TENANT IMPROVEMENT ON 5TH FLOOR LOUNGE AT TOM BRADLEY INTERNATIONAL AIRPORT FOR KOREAN AIRLINE SPACE 5C2-10, 5, new lighting, title 24, power,  Total load of 152 Amps  Max verified fromk master plan.  Total actual load is 146 Amps.  Variance is filed to seperate fire alarm from power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42010	16041-10000-25383	700 S FLOWER ST # 2340	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	Full PC for power and energy. Change of use for a portion of an existing office space into a medical office. Scope includes new lights, receptacles, and one 100A panel.  Total affected area: 3,053 sq.ft. B#16016-10000-17048note only 1 exit required. exit signs and lighting optional	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42011	16041-10000-30457	12117 W BURBANK BLVD	91607	2	174B165   706	2340026076	P-1VL, [Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.1723	-118.39712	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.TOTAL AREA (INDOOR) 5250 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42012	17041-10000-29580	835 W JEFFERSON BLVD 1750	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Issued	09/27/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	PC FOR POWER AND ENERGY FOR A FIRST TIME TENANT (SLOE BICYCLE) IN BUILDING 7 (THE VILLAGE AT USC). SCOPE INCLUDES NEW PANEL LIGHTS AND RECEPTACLES TOTAL CONNECTED LOAD 1047 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42013	17041-20000-00718	19701 S HAMILTON AVE 1st & 2nd-Floor	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	33.85221	-118.28625	Plan check for Title 24 only. Project site is the 1st and 2nd floors of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,060 sq. ft.Note: Building application has been generated under 16016-10000-30968	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42014	18041-10000-45896	9400 N TOPANGA CANYON BLVD	91311	12	198B101   334	2746013038	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.24111	-118.60592	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42015	13041-10000-35386	1015 S CROCKER ST Q09	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH FLUORESCENT FIXTURES. 1612 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42016	12041-20000-03337	1824 E MARENGO ST	90033	14	133-5A223  70	5201017051	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM			PC Approved	03/09/2012 12:00:00 AM	ADDRESS	34.05786	-118.21087	TI TO AN EXISTING TAKE OUT RESTAURANT. INTERIOR REMODEL AND NEW KITCHEN EQUIPMENT.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42017	12041-10000-15210	701 W CESAR E CHAVEZ AVE #107	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.06107	-118.24412	First time tenant, new restaurant.  Full Plan review for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42018	13041-20000-23653	26613 S PRESIDENT AVE	90710	15	030B193   188	7411025001	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	33.78021	-118.30375	PV1 MICROINVERTER SYSTEM. 2.1KWAC SYSTEM. 10 MODULES AND 10 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42019	15041-20001-27173	19429 W KINZIE ST	91324	12	201B117   189	2761010015	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.24879	-118.55661	Expedited per customer request.PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel. (46) Hyundai HIS-S270(2) ABB PVI-6000 Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42020	11041-20000-19031	11100 W SANTA MONICA BLVD 9TH FL	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM			PC Approved	09/08/2011 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR NEW 9TH FLOOR PANTRY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42021	17041-30000-46301	590 N VERMONT AVE 2nd Floor	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	34.08157	-118.2915	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,403 sq. ft.Note: Building application has been generated under 17016-30000-38241	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42022	12041-10002-26711	738 E 12TH ST B	90021	14	123A211    36	5132012035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.03297	-118.25214	Modification to previously approved set of plans (12041-10000-26711).  The modifications are to the light fixtures ( Fixture A:  track fixtures went from 3.5 W to 10 W and Fixture B: the pendant lights from 150 W to 120 W.  Plan check is for energy only.<<<<PLAN CHECK FOR ENERGY. 1 STORY. TI EXISTING BUILDING 2055 SF. LOAD LESS THAN 100A>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42023	17041-20000-11229	5757 W WILSHIRE BLVD suite 659	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE SPACE . 1599 SQFT.  SUITE 659""COMPLY WITH DEPARTMENT ORDER effective date02/16/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42024	14041-10000-28948	10979 W BLUFFSIDE DR BLDG 6	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	Note to plan check engineer, applicant returns and swaps in a new plan with additional circuits added on after original fee was paid. Plan check engineer needs to verify fee with all new changes. Per F.Y.(((Installing new washer/dryers and booster fans in apartment units.  Bldg 6 of 6.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42025	15041-20000-17837	7453 N FALLBROOK AVE	91307	12	186B097   539	2021016022	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.20577	-118.62363	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Inteconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. (38) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42026	11041-10000-01309	6254 W LEXINGTON AVE	90038	13	144B189   405	5534006025	C2-1D	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	34.09244	-118.32623	T24 light plan check for remodeled  Taco Bell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42027	17041-20000-21244	15503 W VENTURA BLVD STE 300	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.15504	-118.4723	PLANCHECK FOR T24 ENERGY. 3RD FLOOR EXPANSION FOR COMMERICAL TI. 2894 SQFT. 3RD FLOOR SUITE 300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42028	16041-20001-42834	19840 W KINZIE ST	91311	12	201B113   410	2761019020	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.24822	-118.56594	2.28.2017 - Plan check for modification to approved set. Add pv meter only. Change reflected on site plan and single line diagram.======PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.2KWac.(35)MODULES-SUNPOWER SPR-X21-345-C-AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42029	15041-10000-33197	1435 W 7TH ST	90732	15	015B193   409	7459001016	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	33.7377	-118.30896	INSTALL NEW FA SYSTEM FOR A  two-story temple(assembly Area). 93 DEVICES, ONE FA PANEL AND ONE AMPLIFIER PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42030	13041-10001-32275	758 E 107TH ST	90002	8	090A207   403	6051023034	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	33.93913	-118.26101	Expedited RSES plan check per applicant request.(((PV1, Install 3.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 15 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42031	18041-10000-45444	106 S KINGS ROAD 1-9	90048	5	138B173   645	5511016002	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.0742	-118.37198	PLAN CHEK FOR POWER AND ENERGY FOR NEW  4 STORY, TYPE VA,   9 UNIT APARTMENT BUILDING OVER  1 LEVEL, TYPE 1A, SUBTERRANEAN GARAGE. SERVICE SIZE = 800A AT 120/240V 3 PHASE WITH 5 TYPICAL UNITS. TOTAL AFFECTED AREA = 8585 SF.INDOOR AREA MISSING FROM SUBMITTED SET OF PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42032	15041-20000-43426	21860 W BURBANK BLVD SUITE 110	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.17198	-118.60379	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE/CONFERENCE/LOUNGE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES ON SUITE #110. TOTAL AFFECTED AREA IS 2281 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42033	18041-20000-06479	11970 W VENTURA BLVD	91604	2	162B169   144	2369016034	C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	PIN	34.14328811	-118.39283103	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,573 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42034	19041-20000-06758	10949 N CARTWRIGHT DR	91311	12	210B113   247	2708029006	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2019 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.27001	-118.5666	PV1.  Install 6.03 kW roof mounted grid tied PV system.  (18) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42035	11041-10000-26197	7257 W BEVERLY BLVD	90036	5	138B181   379	5525036028	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM			Corrections Issued	12/08/2011 12:00:00 AM	ADDRESS	34.07632	-118.3478	PLAN CHECK T24 ENERGY/EMERGENCY PLAN CHECK TENANT IMPROVEMENT WEIGHT WATCHERS RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42036	18041-20002-00413	13100 W GRIDLEY ST	91342	7	222B161    19	2512027030	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Issued	07/31/2018 12:00:00 AM	ADDRESS	34.30958	-118.41836	07/31/2018 Changes to an approved set of plans. PV system inverter has changed and there has been the addition of (1) module. System size is now 3.52 kWdc/3.19 kWac-CEC and consists of (1) inverter, (11) modules, (1) load center, and (1) Tesla PowerWall.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (10) modules, (1) load center, and (1) Tesla PowerWall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42037	12041-10000-21529	7221 N VAN NUYS BLVD	91405	6	183B149    24	2218024015	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	12/05/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.20192	-118.44901	"TENANT IMPROVEMENT FOR ""THE HABIT BURGER"" RESTAURANT IN AN EXISTING RETAIL SPACE (FORMERLY HOLLYWOOD VIDEO).  CHANGE OF USE FROM RETAIL TO RESTAURANT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42038	15041-10000-41301	850 S HOPE ST	90071	14	129A209   239	5144020020	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	PIN	34.04556592	-118.25943122	Power plan check for (2) new services located in the ground floor of a parking structure with design load only. Scope includes (1) 1600 Amp and (1) 4000 Amp services. The plan will be pulled under permit only, and the permit will be finalized at the same time as the permit #: 13041-10000-35730 (1200 Amp service located in the same location). (((          permit #: 13041-10000-35730PLAN CHECK FOR POWER AND ENERGY FOR NEW PARKING STRUCTURE. SUBMITTAL FOR PARKING AND RETAIL. BUILDING # 13010-10001-01140)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42039	12041-20000-14291	668 E ROSE AVE	90291	11	111B145   805	4240011039	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.00005	-118.46994	energy plan check attached to single family	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42040	16041-20001-08963	5410 N RHODES AVE	91607	2	171B165    39	2347006***	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			Corrections Issued	04/05/2016 12:00:00 AM	ADDRESS	34.16912	-118.40293	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a commercial building. Interconnect with a 400A MSP.System size: 20kW (10+10). Ungrounded system. (63) 265W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42041	19041-20002-33703	2377 N JUPITER DR	90046	4	153B177   484	5569008012	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.11254	-118.36361	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, REMOVAL OF ONE PV MODULES, ONE MICRO INVERTER, CHANGE TO ROOF LAYOUT, SINGLE LINE, AND SIGNAGE PAGE. ALSO CHANGED MAIN PANEL, NO LONGER A PANEL UPGRADE AND MAIN BREAKER IS NOW BEING DERATED TO 175A. PV SYSTEM SIZE IS REDUCED FROM 13.2 KW DC/12.6 KW AC TO 12.87 KW DC/12.285KW AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42042	18041-20000-26655	14543 W VENTURA BLVD	91403	4	166-5A151  96	2265010005	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.15133	-118.45015	Plan check for Title 24 Energy only in existing restaurant  T.I. Total area: 1722 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42043	15041-20000-26597	19014 W VENTURA BLVD	91356	3	174B121   461	2163021021	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	PIN	34.17218927	-118.54784155	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT TO RESTAURANT. 1208 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42044	15041-20001-24087	28114 S WESTERN AVE Unit #3	90732	15	024B193     4	7442030206	P-1XL, [Q]C2-1XL, [Q]C4-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	33.76399	-118.31018	02/19/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4. Changes include details for (2) relocated panels .*****Previous Work Description*****TI to eixisting commercial building. Change of use from retail to veterinarian clinic. Plan check for power and energy. Adding new lighting including emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42045	14041-10000-02439	3377 W WILSHIRE BLVD # 107	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.06193	-118.29742	TENANT IMPROVEMENT IN EXISTING TAKE-OUT RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42046	14041-10001-28819	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Issued	03/30/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	Changes to approved set. Update some items per as built. revised some lighting and providing updated title 24. Addition of DC sysmtem for control of switch gear.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42047	16041-10000-24333	515 N HOMEWOOD ROAD	90049	11	135B137   250	4426036003	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.06761	-118.48758	PV1 roof mounted solar system installation to a single family home. Installing 45 Microinverters rated at 250 Watts each (M250-60-2LL). Total system size is equivalent to 11.25 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42048	18041-20000-06369	4355 N LEMP AVE	91604	2	165B169   435	2365020011	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Issued	02/21/2018 12:00:00 AM	ADDRESS	34.14878	-118.38459	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (26) modules, (2) load centers, and (1) PowerWall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42049	17041-20002-43969	17550 W EMBASSY DR	91316	5	171B129   318	2257008047	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.16329	-118.51589	PC for changes to approved set. Changing module and string layout on rooftop. Downsizing PV breaker to 110A. (Inspector to verify that disconnect is minimum 22kA SCCR rated and a 2/0 GEC is installed)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42050	13041-10002-30055	5513 N VOLETTA PL	91607	2	174B161   578	2346001007	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.17069	-118.41123	Expedited RSES plan check per applicant request.(((PV1, Install 7 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 28 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42051	17041-20000-14839	14000 W DAVENTRY ST	91331	7	207B153   624	2618006011	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.2633	-118.43838	Plan check for solar pv system, roof-mounted on SFD.3.8kW ungrounded system. (13) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42052	15041-10000-06810	10149 N CANOGA AVE	91311	12	204B105   508	2747010010	[T][Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.25505	-118.59748	REPLACING HID LUMINAIRES WITH  LED LUMINAIRES IN BAYS OF AN AUTO REPAIR SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42053	15041-10000-02205	5232 E ALHAMBRA AVE	90032	14	138A235    36	5217019021	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.07414	-118.17142	Plan check for power. Service upgrade from 200 amps to 600 amps. Installation of a new 600-amp rated board. Project site is an existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42054	12041-10000-17593	400 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			PC Info Complete	07/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	TITLE 24 , AND FIVE CIRCUITS. LAX	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42055	19041-10000-48878	3113 S QUEENSBURY DR	90064	5	123B161   342	4316005002	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.03508	-118.40764	$0 fee due to AB1414 (E-PLAN)CHANGES FOR AN APPROVED SET FOR EQUIPMENT RELOCATION.ALL NUMBER OF MODULES AND INVERTER STAYED THE SAME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42056	15041-10000-03381	1060 S HOPE ST	90015	14	127-5A207 254	5139008010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.04228	-118.26281	New fire alarm system with (1) fire alarm panel, (1) power supply, (1) communication panel, and (68) devices for a six-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42057	17041-10001-19475	6130 S AVALON BLVD	90003	9	105B205   683	6007009025	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM			PC Approved	03/15/2019 12:00:00 AM	ADDRESS	33.98365	-118.26499	"SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, INSTALLING NEW OUTLETS AND CHANGING SOME EQUIPMENT FROM SINGLE PHASE  TO 3 PHASE.*ORIGINAL*PC FOR TI, POWER AND ENERGY FOR ""LA FOOD PREP""SCOPE INCLUDES NEW SERVICE 2500A 480/277VINSTALLING NEW EQUIPMENT CIRCUITS AND LIGHTING TOATL AFFECTED AREA 58558 SQ.FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42058	11041-20000-19605	700 S FLOWER ST # 2325	90017	9	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM	09/15/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING OFFICE #2325 TI; PERMIT FOR NEW CKTS. COMPLY WITH DEPARTMENT ORDER effective date 04/28/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42059	15041-10000-19104	2669 N GRIFFIN AVE 1-40	90031	1	139-5A223  23	5206005018	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Expired	07/13/2017 12:00:00 AM	ADDRESS	34.07847	-118.21203	EXISTING APARTMENTS. REPLACE EXISTING SERVICE TO 600A, NEW 1000A DISTRIBUTION BOARD, AND SUB PANELS. ALL LOADS IN BUILDING ARE EXISTING TO REMAIN. PLAN CHECK FOR POWER OINLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42060	14041-10001-16663	6411 W IMPERIAL HWY	90045	11	087B165    12	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	33.93238	-118.3989	CHANGES TO PERMITTED SET OF PLANS-NEW 125HP FIRE PUMP AND 2 HP JOCKEY PUMP(((((((NEW 1000 AMP SERVICE AND NEW HANGAR WITH NEW OFFICE FOR LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42061	19041-20000-13992	3034 1/4 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42062	16041-10001-03985	12511 W VENICE BLVD	90066	11	111B153   213	4246026007	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.00326	-118.43497	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42063	19041-10000-14588	3726 S KELTON AVE	90034	5	117B161   629	4252025030	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	10/01/2020 12:00:00 AM	ADDRESS	34.01739	-118.4127	NEW FA SYSTEM IN A 5 UNITS APPARTMENT COMPLEX. SCOPE INCLUDES 1 FIRE ALARM PANEL, 1 ANNUNCIATOR AND 26 DEVICES. FA PANEL WITH 2*12V AT 12AH EACH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42064	19041-20000-34714	20212 W VIA MADRIGAL	91326	12	219B113   296	2701062011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.29669	-118.57315	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 16.75KW DC/ 14.23KW AC. SCOPE OF WORK CONSISTS IF (50) PV MODULES WITH MICRO INVERTERS, AND A ENPHASE COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42065	13041-10000-07789	770 W WILSHIRE BLVD Floor 9	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	04/01/2013 12:00:00 AM	ADDRESS	34.04914	-118.25811	Title 24 for a 9th story office highrise retrofit.  9-story building.  7,000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42066	16041-10000-16747	11269 W CAMARILLO ST	91602	2	168B173   462	2353024019	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			05/12/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.15779	-118.37678	Plan check for power and Title 24.  Total area = 10,973 sq. ft. (indoor) + 2,697 sq. ft. (outdoor)NEW 3 STORY, 14 UNIT APARTMENT BUILDING OVER ONE LEVEL SEMI SUBTERRANEAN PARKING GARAGE.  New 1,000 A service. 7 typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42067	18041-10000-39120	6535 N HASKELL AVE	91406	6	180B141   432	2233003060	RD1.5-1-RIO, [Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.18965	-118.47517	4.95 KWdc ROOFMOUNTED PV AC SOLAR UNGROUNDED, INSTALLED ON COMMERCIAL APARTMENT ROOFTOPNEW (15) 330W PANELS MODULES,  AND NEW (1) 5 KWac INVERTER	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42068	16041-10001-33005	801 W D ST	90744	15	030B205  1366	7417015035	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM			Corrections Issued	02/16/2017 12:00:00 AM	ADDRESS	33.77378	-118.2716	ELECTRICAL PLAN CHECK FOR ELECTRIC RESISTANCE HEATERS. REVIEWING PERFORMANCE METHOD OF COMPLIANCETHIS APPLICATION IS PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42069	11041-20000-01451	18645 W VENTURA BLVD	91356	3	174B121   558	2160006038		South Valley				1394.00	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	PIN	34.17094066	-118.54053366	Plan check T24 Energy for beauty salon TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42070	18041-20000-36491	17829 W PALORA ST	91316	5	168B129   143	2182006012	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.15972	-118.52103	permit fee $0.00 by state senate bill no. 1222pv1install roof mounted pv system sized 15.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42071	15041-10005-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			PC Info Complete	10/03/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED AS DELTA17 ON PLANS. SCOPE INCLUDES 1.REVISION TO DEMOLITION PLAN.2. ADDTION OF SQ.FT AND LIGHTING TO SHELL TENANT SPACE CONNECTED TO EXISITING CIRCUITS3. UPDATING CONDUIT RUNS AND SIZE ON PLANSCOPE INCLUDES NEW 8 UNITS REVISION TO TITLE 24 FORMS TO REFLECT CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42072	17041-20000-06556	2205 S CRENSHAW BLVD	90016	10	126B185  1193	5061020047	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.0382	-118.33229	5.23kW single family.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42073	15041-10000-06188	12517 W PINNEY ST	91331	7	213B165   428	2532013003	RS-1	North Valley	Arleta - Pacoima	Pacoima		1042.04	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.28032	-118.40585	PV1CENTRAL STRING INVERTER SYSTEM SIZE 3.8KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42074	13041-20000-35508	11100 W SANTA MONICA BLVD 9th	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	PC FOR T24 ENERGY ONLY. TOTAL AREA 540 SQ FT. NEW LIGHITNG IN EXISTING PANTRY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42075	09041-20001-20529	6400 N LAUREL CANYON BLVD	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.00	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Finaled	03/08/2010 12:00:00 AM	ADDRESS	34.18693	-118.3963	Revision to previously approved plan. T.I for BANK energy, emergency. Change is clouded showing added receptacles and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42076	13041-20000-23791	1361 N AVENIDA DE CORTEZ	90272	11	138B117   321	4431006012	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.07194	-118.56126	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.6 KW USING 18 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42077	19041-10000-51255	11247 N ALTA AVE Lot 42	91345	7	210B145   566	2664007***	P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.27502	-118.46878	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 10 MODULES (HANWHA Q.PEAK BLK-G5315), 10 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)SYSTEM SIZE: 3.15 KW DC;  3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42078	19041-10000-28563	9300 N BALCOM AVE	91325	12	198B129   251	2766006002	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Issued	08/13/2019 12:00:00 AM	ADDRESS	34.23917	-118.52141	***$0 Permit fee due to AB1414*** NEW ROOFTOP SOLAR SYSTEM CONSIST OF 63 MODULES (Q-CELL 305) , 63 OPTIMIZER (SE P320) AND 2 CENTRAL INVERTER (SE7600H-US EACH). SYSTEM SIZE IS 19.215KWdc and 15.2KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42079	14041-20000-06903	9155 N FORBES AVE	91343	12	198B133   496	2687008011	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Expired	05/13/2016 12:00:00 AM	ADDRESS	34.23725	-118.50007	pv1 single family dwelling. total system size 6kw ac using transformerless inverter. nonstandard plan. using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42080	14041-20001-14613	6500 N WHITAKER AVE	91406	6	180B137   481	2231002017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.18881	-118.498	Expedite per customer request6.1KW roof-mounted system with (24) Trina Solar modules (TSM-255PA05.18), (24)  Solaredge Powerbox optimizers (#P300), and (1) Solaredge transformerles inverter (SE6000A-US).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42081	10041-10002-25799	3310 S CENTRAL AVE	90011	9	117A209   419	5114026***	(T)(Q)C2-1L	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/21/2011 12:00:00 AM	ADDRESS	34.01319	-118.25635	Revision to the approved plan. EPC is for Delta 1. (((((((((((((((TI for a coffee shop, no cooking. EPC is for Energy & T24.))))))))))))))0000000  <<<<<<<<<<<<Second revision to plan for lighting only,  PLAN CHECK IS FOR ENERGY ONLY>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42082	16041-10000-02424	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	PIN	34.05182951	-118.41257696	PC for energy only to commercial building (20th century fox theater) studio. Adding new lighting and power. Total sq ft = 1269	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42083	14041-20000-28883	9401 N OSO AVE	91311	12	198B113    99	2748022086	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.2411	-118.57555	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHTING TO EXISTING CIRCUITS.  NO NEW LOADS.  PLAN CHECK FOR ENERGY AND EMERGENCY. TITILE 24 PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42084	14041-10001-33815	1005 E 51ST ST	90011	9	111A209   366	5108015028	RD1.5-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	33.99676	-118.258	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(20) MODULES: YINGLY YL255P-29B(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42085	13041-10000-32758	1500 W PACIFIC COAST HWY BLDG K	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING KTHIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42086	15041-20000-11903	12446 W OSPREY LANE Unit 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.97949	-118.41001	Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (8) modules, and (1) inverter. This is Unit 3 of 3.Note: PV solar clearance shall apply to the three units under this PCAM number.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42087	14041-10000-22925	2132 W LAS COLINAS AVE	90041	14	159A221    81	5685025009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			Reviewed by Supervisor	09/10/2014 12:00:00 AM	ADDRESS	34.13139	-118.21506	PV1, INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(6) MODULES: KYOCEERA KD255GX-LFB3(1) INVERTER: POWEER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42088	16041-30000-35021	17637 W MAYERLING ST	91344	12	213B129    43	2601042028	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.28387	-118.51749	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.  Total area = 41,556 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42089	19041-20000-39296												Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM				VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42090	16041-20000-27046	12669 W SEACOAST PL	90094	11	102B161  1279	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.9763	-118.41373	PV1.  Install 1.5 kW roof mounted PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42091	13041-10000-34534	12510 S VERMONT AVE	90044	15	081B197   234	6117017044	R2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	33.91811	-118.2914	PV1, Install  4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] on a 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42092	12041-10001-18043	682 W HARRY BRIDGES BLVD Operations	90744	15	027B201   336	7440015***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM			PC Approved	12/05/2012 12:00:00 AM	ADDRESS	33.77	-118.26886	Fire alarm for NEW 1-STORY YARD OPERATIONS BUILDING FOR THE PORT OF LA.  (PART OF TRAPAC TERMINAL PROJECT).   Main building is on the supplemental permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42093	18041-10000-30985	6150 N LAUREL CANYON BLVD Bld-H	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	PLAN CHECK FOR POWER AND ENERGY FOR - 2-STORY INTERIOR TENANT IMPROVEMENT FOR FITNESS CENTER LOCATED INTHE NOHO WEST BUILDING H. ALSO INCLUDED IS INDOOR SWIMMING POOL AND SPA. - NEW 1600A PANEL CONNECTED TO EXISTING SERVICE WITH TOTAL OF 33279 SF OF AFFECTED AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42094	13041-10000-08775	1320 N ECHO PARK AVE	90026	13	139-5A209 128	5419028011	[Q]C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.07735	-118.25675	Title 24 for a restaurant TI.  Single-story bldg, 1600 sq ft.  No required emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42095	17041-30000-36231	3280 S MOTOR AVE	90034	5	123B161   963	4314024020	M1-1	West Los Angeles	West Los Angeles			2699.07	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	04/21/2021 12:00:00 AM	ADDRESS	34.02969	-118.41085	Plan check for fire alarm system for 2 story office. Total fire alarm devices: 81 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42096	16041-10000-02233	3889 N WEST POINT DR	90065	1	145-5A223 238	5451022013	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			Corrections Issued	01/21/2016 12:00:00 AM	ADDRESS	34.09276	-118.21314	PV1, ROOF MOUNTED SOLAR SYSTEM WITH CENTRAL INVERTER. (13) MODULES AND (1) 5KW-INVERTER. TOTAL SIZE 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42097	14041-10000-30714	12041 W WILSHIRE BLVD 8 & 10	90049	11	126B145    53	4265016046	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	PIN	34.04519158	-118.46671786	Energy plan check for a change of use from a retail to a spa area. total cover 700 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42098	13041-10000-32746	1500 W PACIFIC COAST HWY POOL BLDG	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM			PC Info Complete	12/20/2013 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. POOL BUILDING. DEVICES WERE REMOVED DUE TO NATURAL VENTILATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42099	14041-20001-23765	17350 W LOS ALIMOS ST	91344	12	207B129   317	2696006002	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.26589	-118.51275	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(56) KYOCERA KD 255 MODULES(1) FRONIUS INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42100	14041-10000-15364	737-741 S BROADWAY	90014	14	127-5A209  77	5144014030	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Issued	09/19/2014 12:00:00 AM	ADDRESS	34.04443	-118.25434	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE and 17 panels. REMOVE EXISTING 2000 AMP SERVICE SINGLE METER WITH NEW MULTI METER SERVICE. Breakers are fully rated. See attachment for vertical support details.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42101	11041-20000-20785	500 S VIRGIL AVE	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Remodel of a medical office.  Service upgrade from one 2000 amp service to two 2000 amp services.  Plan check is for power and energy. Methane Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42102	10041-20000-22782	1521 W PICO BLVD 1-56	90015	1	127-5A203 102	5137032023	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Apartment			11/15/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.04432	-118.27583	FIRE ALARM APARTEMENT BUILDING 3 STORIES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42103	17041-20000-17562	13061 W VICTORY BLVD	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.18924	-118.41735	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT . CHANGE OF USE FROM RETAIL TO MASSAGE PARLOR. 1330 SQFT. BUILDING P# 17016-20000-06877	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42104	18041-20000-33152	13401 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	02/04/2022 12:00:00 AM	ADDRESS	34.15778	-118.42471	Plan check for a fire alarm system for a 3-story apartment building. System consists of (1) FACP, (1) annunciator, and (79) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42105	11041-10000-14281	5115 W WILSHIRE BLVD	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.06233	-118.34134	T.I.  Beauty salon in suite # B.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42106	19041-10000-30786	2707 S CENTRAL AVE	90011	9	118-5A209 286	5128023037	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.01754	-118.2557	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42107	12041-10000-31134	4759 E LINCOLN AVE	90042	14	156A223   226	5477003041	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	12/31/2012 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	34.12163	-118.21188	PV1 2 STORY HOUSE 14 MODULES [MODULE: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY {M215-60-2LL-S22}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42108	16041-20000-31717	3850 S CRENSHAW BLVD	90008	10	117B185   775	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.01602	-118.33474	"TI TO AN EXISTING BUILDING.  REPLACEMENT OF EXISTING PANELS ONE FOR ONE.  ADDITION OF NEW PANEL ""AC"" NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 9905"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42109	18041-20000-47722	3899 S 2ND AVE	90008	8	117B189  1269	5034017002	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.01477	-118.31947	Plan check for PV roof mounted system, system size: 2.07kW with 7 PV Modules and 7 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42110	15041-20000-30093	9250 N RESEDA BLVD Suite 8	91324	12	198B125   208	2764012014	P-1VL, QC4-1VL, QP-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			Corrections Issued	09/11/2015 12:00:00 AM	ADDRESS	34.23857	-118.53589	Title 24 plan check only.  Total area = 3,402 sq. ft.  T.I. to existing restaraunt space.  New lighting, recepticles, cooking equipment, and HVAC.  Existing 400 A service to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42111	14041-10000-13076	4771 N FIRMAMENT AVE	91436	5	168B141   384	2261030007	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.15801	-118.47286	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 5.1KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42112	14041-10001-05589	19344 W RINALDI ST SUITE N	91326	12	210B117    25	2822019012	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	34.27346	-118.55532	((((6/5/2014- Changesmade to approved set.  Remove track light and replace with flourescent light))))Renovation of an existing commercial space for a nail salon and spa.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42113	15041-20000-27907	14850 W OXNARD ST	91411	4	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.17924	-118.45706	Plan check title 24 only for existing space T.I. lighting shop. Total indoor area: 4,226 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42114	13041-10000-21705	16300 S AINSWORTH ST	90247	15	069B197   328	6120018037	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Apartment			08/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	33.88328	-118.29014	PLAN CHECK POWER AND ENERGY FOR PROPOSED 2-STORY SEVEN UNIT APARTMENT BUILDING. NEW 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42115	14041-10000-23471	21860 W BURBANK BLVD BLDG B	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.17198	-118.60379	PHASE 2: : PV2 ROOF MOUNTED SOLAR SYSTEM. NEGATIVELES GROUNDED. NO NEW INVERTERS. TIED BACK INTO THE OLD SYSTEM.(60) YINGLI YL MODULESPHASE 1: 13041-10000- 29243 photo voltaic roof top for a 3 story bldg,768 modules, 3 combiner boxes, 2 inverters, Roof mounted , flat roof. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42116	15041-10000-22507	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022	A1-1-H, A2-1, PF-1XL, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM			PC Approved	07/20/2015 12:00:00 AM	ADDRESS	34.08694	-118.47588	Energy plan check for a new outdoor restroom. scope include in/outdoor lighting; Total area is 2111-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42117	10041-10000-10921	3900 N STANSBURY AVE DP1 & DP3	91423	5	162B153   353	2274027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.14084	-118.44264	TI in an existing school. RECONNECT EXISTING PANELS & LOADS TO TWO NEW DISTRIBUTION PANELS DP1 & DP3 CONNECTED TO 2 @ EXISTING 800 AMP SERVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42118	18041-20000-29737	20801 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.29518	-118.58672	pv1install roof mounted pv system sized 3.8 KW AC interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42119	15041-20000-00759	13016 W GLAMIS ST	91331	7	204B161   202	2623010010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.2569	-118.41639	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.3KW INTERCONNECTED WITH MSP.(34) ENPHASE M-215 MICROINVERTERS(34) HYUNDAI HEAVY HIS-M250	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42120	17041-20001-00644	18562 W LEMARSH ST	91324	12	204B125   277	2729012026	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.25488	-118.53825	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42121	15041-20001-07068	8124 W 3RD ST	90048	5	138B173   960	5511029032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.0721	-118.36676	[[[8/4/15  changes to approved set. delta 2 changes only. changing the voltage to reflect the installtion]]]]600 AMP SERVICE UPGRADE TO AN EXISTING 2 STORY COMMERCIAL BUILDING. EQUIPMENT LOCATED OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42122	17041-20002-06194	7224 W FOOTHILL BLVD	91042	7	202-5A199 563	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			PC Approved	03/16/2017 12:00:00 AM	PIN	34.2482179	-118.28964176	Plan check only for first time tenant.  Plan check for power/NEC requirements.  (((TI and change of use from retail to adult education class room.  Emergency egress lighting existing to remain per applicant.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42123	16041-20000-33503	109 N BOYLE AVE	90033	14	129A221   117	5174024021	[Q]C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.04798	-118.21985	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to a vet clinic. Total lighting area = 2,478 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42124	18041-10000-10624	1581 E INDUSTRIAL ST	90021	14	124-5A215  35	5164010002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Issued	03/23/2018 12:00:00 AM	ADDRESS	34.03608	-118.23629	Plan check for Title 24 remove HID fixtures and replace with new LED fixtures indoor lighting. Total area: 16,800 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42125	12041-20000-29542	9200 N OAKDALE AVE	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/07/2012 12:00:00 AM			PC Approved	12/07/2012 12:00:00 AM	ADDRESS	34.23811	-118.56674	energy plan check office emergency lighting existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42126	18041-10000-03936	923 E 3RD ST #107	90013	14	129A217   170	5163006016	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04611	-118.23427	REPLACE INDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42127	15041-10000-14585	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Closed	01/22/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	TERMINAL 7 TICKETING, SSCP AND BAG CLAM. PC FOR POWER AND ENERGY. PC FEES ESTIMATED PER APPLICANTS APPLICATION ADDITIONAL FEES MAY BE REQUIRED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42128	16041-20001-29874	1251 E 21ST ST	90011	9	120A211   149	5131009030	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	34.02331	-118.25271	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42129	17041-20000-08385	1880 S CENTURY PARK EAST	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM			PC Approved	03/15/2017 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only. Project site is common area restrooms on floors 2,3,4,7,8,9,10,11,12,15, and 16 of a commercial building. Project scope is restroom remodels. Total lighting area = 5,110 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42130	11041-20000-14754	8540 S SEPULVEDA BLVD	90045	11	096B165   472	4107035017	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			Ready to Issue	08/12/2011 12:00:00 AM	ADDRESS	33.96016	-118.39599	Ti in a dental office. EPC is for Power & T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42131	17041-10000-43761	21530 W GLEDHILL ST	91311	12	198B105    69	2746014040	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.24116	-118.59974	REPLACE EXISTING OUTDOOR FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42132	19041-10000-00025	5800 W SUNSET BLVD	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.09728	-118.31693	FIRE ALARM SYSTEM REPLACEMENT FOR A COMMERCIAL ACTING STAGES PROPERTY. THE FIRE ALARM IS COMBINED BETWEEN ALL 16 STRUCTURES WHICH CONSIST OF BUILDINGS AND STAGES. FIRE APPROVAL MUST BE OBTAINED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42133	17041-10000-07120	1120 S GRAND AVE	90015	14	126A207    60	5139020094	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	34.04095	-118.26231	PC FOR FA SYSTEM. 38 STORY HIGH RISE WITH 2 BASEMENT LEVELS. 2351 FA DEVICES AND 29 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42134	16041-10000-28891	10321 N TUJUNGA CANYON BLVD	91042	7	204B197   732	2558020019	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.25654	-118.29144	Remove Outdoor HID fixtures and replace with new LED fixtures TI-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42135	17041-10000-15113	210 S WOODRUFF AVE	90024	5	141B153   302	4359008003	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.0786	-118.43577	Power plan check.  Remodel of existing single family dwelling.  Complete new power distribution system including 600 amp service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42136	14041-10000-14530	6833 N VAN NUYS BLVD	91405	6	183B149   681	2219025024	C2-1L, P-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.19492	-118.44899	plan check for energy only.  TI TO ARBY TO STARBUCKS. LESS THAN 400A. BLDG#:14016-10-10166. changes on plans include manufacturer of two luminaires.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42137	10041-20001-24393	14006 W RIVERSIDE DR #8	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM			PC Approved	12/08/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLAN CHECK FOR NEW 800A SECTION TO SUPPLY NEW FOREVER 21 TENANT. FOREVER 21 CONNECTED LOAD PER APPROVED PLAN CHECK #10041-10000-09475 IS 499A. AIC RATING SHALL MATCH EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42138	15041-10000-16846	6055 W CENTER DR	90045	11	102B169   958	4104001087	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM			PC Info Complete	11/18/2015 12:00:00 AM	ADDRESS	33.97625	-118.39025	Plan check for power and energy. Project site is a new 7-story apartment building (109 units). NOT HIGH RISE. Total indoor lighting area = 124,844 sq. ft. and total outdoor lighting area = 17,589 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42139	15041-10000-31178	5831 N FIGUEROA ST	90042	1	151-5A229 122	5492012025	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.11066	-118.1911	CHANGE OF USE FROM RETAIL TO RESTAURANT .PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42140	15041-20000-36835	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.97615	-118.42138	Core&Shell of a new build.. MSB 2500A. Building located on a Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42141	19041-20002-10404	16909 W ARMSTEAD ST	91344	12	213B133   224	2610009004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.28259	-118.50024	expeditepv1install roof mounted pv system sized 7.6KW AC with battery 5KW interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42142	11041-10000-23496	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022		West Los Angeles	Brentwood - Pacific Palisades		YES	2622.00, 2623.02	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	34.08694	-118.47588	Plan submittal to replace expired originals approved under PCIS 10041-10000-08310, including a revision of the generator location.(Replace emergency generator from a 175Kw to 500Kw at the existing building (Getty Center).  Install new switchboard, panel, and two ATS.  Plan check for power only.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42143	18041-10000-33629	6707 W 88TH ST	90045	11	096B161   808	4122020011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	33.95725	-118.4071	PLAN CHECK FOR BATTERY(TESLA POWERWALL 13.5 KWH) BACK UP SYSTEM FOR SFD - (SFD ALREADY HAS A PV SYSTEM (5KVA) - PHYSICAL PROTECTION TO BE VERIFIED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42144	17041-10000-31612	1100 W SLAUSON AVE	90044	9	108B197  1495	6003003044	P-1, [Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	33.98896	-118.29321	PC FOR tenant improvement IN (e) grocery store FOR A NEW HOT FOOD SERVICE AND SITTING AREA.  addition of new hot food service dent and non fixed tables and chairs 1747 s.f.TOTAL AFFECTED AREA 31,280 SQ.FT. SCOPE INCLUDES NEW LIGHTS, EQUIPMENT AND RECEPTACLES.B#17016-10000-25502	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42145	17041-10001-18985	1380 W HILL DR	90041	14	163-5A227  55	5691007009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.14389	-118.19458	EXPEDITE FEESPC FOR PV SYSTEM WITH BATTERY STORAGE UNIT. PV RATED 5.2KW AC WITH 20 MODULES AND BATTERY UNIT RATED 5.8KW WITH A CAPACITY OF 13KWH. INSTALL SOLAR LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42146	19041-20000-36013	14250 W MCCORMICK ST	91401	4	171B153   414	2248021015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.16565	-118.44387	Plan check for PV roof mounted system, PV system size: 5.94KW DC, 5.386KW AC with 18 PV Modules and 9 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42147	14041-10000-07320	389 TERMINAL WAY MARINE	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Public Safety Only			03/19/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	PIN	33.74647892	-118.27942177	Upgrade fire alarm system for port of LA MARINE BLDG. (3of 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42148	10041-20000-24099	9401 N OAKDALE AVE	91311	12	198B113    96	2761040020	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/03/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.24135	-118.56701	New fire alarm  systems for Data rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42149	11041-10001-27553	1534 N MCCADDEN PL	90028	13	147A185    20	5547020031	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.09903	-118.33746	SUPPLEMENTAL FOR LOST SET OF PLAN FOR A REACTIVATED PERMITPLAN CHECK POWER AND ENERGY FOR RESTAURANT TI, NOT FIRST TIME TI. NEW 600A 120/240V 3P SERVICE ELECTRICAL SYSTEM. TOTAL SQFT 5000. T24.rechecking 2011 plans per inspector, call mike packard for verification	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42150	18041-10000-37143	20929 W VENTURA BLVD UNIT 36	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	new panel and ckts in exisiting retail spacePLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42151	17041-10000-42103	2832 S MEDILL PL	90064	5	126B165   975	4308017018	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.03841	-118.40078	PC for rooftop solar for 7.6kW system. Installing 26 modules and central multimode inverter and backup battery (battery under 17041-10002-42103).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42152	16041-10000-40308	140 N AVENUE 19	90031	1	139-5A219 127	5447015901	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.07481	-118.22282	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures. Total affected area is 115150 Sq. Ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42153	12041-10001-05668	1340 S FIGUEROA ST	90015	14	126A205    86	5134010016	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.03951	-118.26852	revisions to permitted set of plans (FY)NEW MIXED USE 171 UNIT APARTMENT COMPLEX, 7 STORIES WITH SUBTERRANEAN PARKING. PLAN CHECK POWER AND ENERGY. TWO SERVICES SUPPLYING BUILDING. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42154	16041-10000-35245	300 WORLD WAY T3-Temp power	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Closed	01/19/2018 12:00:00 AM	ADDRESS	33.94502	-118.40714	Plan check for Temp power only in LAX Termial #3 for construction. 600A Distribution gear, transfromers and associated load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42155	14041-10001-32844	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM			PC Approved	03/20/2015 12:00:00 AM	ADDRESS	34.07583	-118.37407	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES CLOUDED DELTA 6.  CHANGES INCLUDE DIFFERENT FIXTURES.T24 and power plan check.  Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects. Area = 1849 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42156	14041-20000-18606	19911 W NORTHRIDGE ROAD	91311	12	207B113   154	2708020019	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			Reviewed by Supervisor	10/31/2014 12:00:00 AM	ADDRESS	34.26201	-118.56715	PV1.  Install 11.6 kW utility-interactive PV system.  System to be ground-mounted.  Point of interconnection made at 400A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42157	12041-20000-11744	6301 W 3RD ST	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM			PC Approved	05/22/2012 12:00:00 AM	ADDRESS	34.07243	-118.35963	T.I. to existing restuarant in suite N-1 of building N.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42158	15041-10000-42382	12130 W MILLENNIUM #  02-129	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	33.98008	-118.40646	INTERIOR TENANT IMPROVEMENT.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42159	18041-10001-07063	1850 N CHEROKEE AVE BLDG 2	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM			PC Approved	07/22/2019 12:00:00 AM	ADDRESS	34.10481	-118.33464	"CHANGES TO AN APPROVED SET OF PLANS. SCOPE OF WORK INCLUDES REVISION TO SITE LIGHTING, FIXTURE MANUFACTURER, AND RECEPTACLES. NOTE CHANGES ON DELTA 4. PC ONLY._______________________________________________________PC for power and energy for change of use from apartment to hotel. Scope includes new panel ""3F"", lights, receptacles and equipment. This building is 2 of 2 for project and consists of three units and is served by main service located in building 1 (18041-10000-07066). Building 2 # 18041-10000-05773. Building 1 # 18041-10000-05775."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42160	11041-10000-24467	1024 E LAKE ST BLDG 59	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.00165	-118.46008	Lincoln Place Apartment Building Project.  New 2-story Recreational Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42161	11041-20000-25703	444 S FLOWER ST 12th fl.-restrooms	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	12th floor restrooms t.i.Energy, emergencyFire/Life system is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42162	18041-20002-01018	14711 W ROUND VALLEY DR	91403	4	162B149    65	2276034041	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.1442	-118.45288	Supplemental to changes to approved set of plan - changes included relocation of solar mudules - all single line information remains the same. Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (1) load center, and (45) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42163	16041-20000-35123	20126 W JUBILEE WAY	91326	12	213B113   407	2701087040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.28234	-118.57251	pv1install roof mounted pv system (acm) sized 6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42164	15041-20001-03443	18528 W CHASE ST BUILDING B	91324	12	192B125   315	2785018029	R3-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Apartment			07/28/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.22434	-118.53707	07-28-2016 Changes to an approved set of plans. Changes include 1 additional panel and lighting fixture type changes in corridor and additional lighting fixture on the roof deck. Changes apply to delta A only*****************Previous Work Description*************************************PC FOR 17 UNIT APARTMENT. TOTAL UNITS ON LOT 28. THIS IS SUBMITTAL 2 OF 2. THIS PLAN CHECK IS FOR 17 UNITS LOCATED AT BUILDING B. BOTH BUILDINGS ARE SERVED BY A SINGLE UTILITY TRANSFORMER.FIRE ALARM VARIANCE HAS BEEN FILEDPC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42165	13041-20000-03420	2035 E BAY ST	90021	14	123A217   144	5166012006	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.03162	-118.23083	Plan check for power and energy. New 600A service. Most units (electrical systems) are typical.TENANT IMPROVEMENT OF . EXISTING BUILDING (URM BUILDING).  DIVIDE INTO 16 TENANT SPACES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42166	13041-20000-17941	800 S HOPE ST	90017	14	129A209   202	5144020900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Info Complete	10/29/2013 12:00:00 AM	ADDRESS	34.0463	-118.25904	NEW PANELS AND NEW 225KVA TRANSFORMER. PLAN CHECK FOR POWER. NO ENERGY. WORK DONE IN DATA CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42167	19041-10000-26831	4907 N ARCOLA AVE	91601	4	168B177   247	2420011010	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.15974	-118.35513	[E-PLAN] PV1 . PLAN CHECK FOR ROOF MOUNTED 10KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 31 MODULES USING P400 OPTIMIZERS CONNECTED TO EXISTING 200A SERVICE.SEPARATE PERMIT SHALL BE PULLED FOR PANEL DERATION	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42168	13041-20001-24040	1068 W VIA CORDOVA	90732	15	021B193    83	7445019084	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM			PC Approved	09/26/2013 12:00:00 AM	ADDRESS	33.75466	-118.3014	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING 25 MODULES. 3 STRINGS. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42169	14041-10001-06663	12050 W VENTURA BLVD #201	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	34.14349	-118.39426	plancheck for t24 energy.  Ti in a restaurant. No new panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42170	14041-10000-06216	15066 W SUTTON ST	91403	4	166-5A147 216	2276024003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.14911	-118.46214	PV1, INSTALL .5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(21) MODULES: TRINA SOLAR TSM-250PAO5.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42171	18041-10000-25048	5454 W SAN VICENTE BLVD Unit #5456	90019	10	129B177   115	5085016039	R3-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Apartment			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.05333	-118.35342	Relocation of an existing smoke detector in Unit # 5456.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42172	19041-10000-18034	3016 N WASHINGTON BLVD	90292	11	108B149  1430	4237026047	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	33.98928	-118.45064	Remove HID fixtures and replace with new LED fixtures (Indoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42173	17041-20002-30702	7048 N SEDAN AVE	91307	12	183B097   210	2026028033	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	34.1994	-118.62853	11.20.2017 - Plan check for modifications to approved set. Interconnecting with existing center-fed panel in place (no longer replacing it), update SLD to reflect this change. Center-fed panel variance filed to allow 120% rule per NFPA TIA 14-12.======Plan check for solar pv system, roof-mounted on SFD.12.8kW ungrounded system. (40) 320W AC modules.Derating main breaker.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42174	15041-10002-31864	6430 W SUNSET BLVD 1ST FLOOR	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	34.09782	-118.32979	1/22/16Changes to an approved set of plan. All changes are made under delta 2. Changes inlcude removing lighting fixtures and adding a second inverter for emergency lighting. (((1/20/2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1. (((Energy plan check for a change of use from office to coffee shop; Scope includes new lighting, receptalce, and equipment; Total area is 1994-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42175	19041-10000-50153	3702 S PARKER ST	90731	15	006B197   634	7469027016	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Info Complete	12/09/2019 12:00:00 AM	ADDRESS	33.71198	-118.29988	[EPLAN] NEW PV1 ROOF MOUNTED INSTALLATION WITH A SYSTEM SIZE 4.160 KW DC/  3.8 KW AC, WITH ONE CENTRAL INVERTER (SOLAREDGE 3800H-US), 13 POWER OPTIMIZERS (P320), 13 MODULES (SLA-M 320W) AND A MAIN SERVICE PANEL OF 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42176	18041-10000-34029	19780 S PACIFIC GATEWAY DR #A-100	90502	15	057B197    48	7351034069	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	33.85141	-118.29512	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42177	13041-10001-32329	4443 N AUCKLAND AVE	91602	4	165B177   174	2424002032	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.15158	-118.36062	Expedited RSES plan check per applicant request.(((PV1, Install 2.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42178	18041-20000-15019	14931 W CALIFA ST STE 100	91411	4	177A149   141	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.17768	-118.4586	Plan check for energy only in ADA shower room existing building. Total area: 138 sq ft.B#18016-20000-10957	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42179	15041-30003-41295	9600 N LURLINE AVE	91311	12	201B109   290	2748040027	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.24455	-118.58404	Changes to approved set.  Instead of supply side tap, AC load center will be connected to MSP with 125 A fuse 200 A breaker AC disconnect switch located on opposite side of bus from main disconnect.  No other changes.         ****Previous Work Description*****NEW DESIGN. INSTALLING 3 INVERTERS. 108 MODULES TOTAL. SYSTEM SIZE 34KW AC. LINE SIDE CONNECTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42180	15041-20000-28675	20915 W ROSCOE BLVD	91304	3	192B109   747	2779007011	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Issued	09/01/2015 12:00:00 AM	ADDRESS	34.22009	-118.58913	TI to existing commercial building. Plan check for energy only. Adding new outdoor lighting. Total sqft. 600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42181	15041-20000-20161	128 S ALTA VISTA BLVD	90036	5	138B181   974	5512024006	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.07276	-118.34728	Installation of new roof mounted solar PV array.  Total system size = 5.25 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42182	12041-10000-13338	6350 W SANTA MONICA BLVD	90038	4	144B185   733	5533016002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.0906	-118.32785	Plan check for power and energy. Low-rise commercial. 24296 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42183	15041-20001-14738	15735 W ADDISON ST	91436	5	171B141   430	2261003014	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM			PC Approved	05/23/2015 12:00:00 AM	ADDRESS	34.16183	-118.47612	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (48) modules, (48) micro-inverters, and (1) 125-amp PV subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42184	18041-20000-17518	21700 W OXNARD ST Suite 1700	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for Title 24 only in existing space new lighting on existing circuits. Total area: 5817 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42185	17041-20000-40201	6535 N ODESSA AVE	91406	6	180B137   401	2231004060	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.18962	-118.49041	Plan check for solar pv system, roof-mounted array on SFD.Derating main breaker to 175A.10.4kW ungrounded system. (2) 5.2kW inverters.(29) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42186	18041-10000-31221	3660 W WILSHIRE BLVD #215	90010	10	132B193   223	5093019020	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.06155	-118.30505	NEW DENTAL OFFICE IN SUITE#220. FIRST TIME TENANT. EPC FOR POWER & ENERGYBLDG PERMIT: 18016-10000-21876	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42187	19041-10000-46154	22236 W DEL VALLE ST	91364	3	171B101   358	2075003025	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.16707	-118.61174	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. TOTAL SYSTEM SYSTEM SIZE IS 5.13 KWDC / 3.8 KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42188	15041-20001-40841	1664 W OAK GROVE DR	90041	14	159A225    59	5689031013	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.13099	-118.20345	EXPEDITE PER APPLICANTPV1, roof mounted solar 6kW AC, interconnect with (E) 200A service.(27) hanhwa q cell Q PRO G4 260(1) SE6000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42189	14041-10000-34942	404 S FIGUEROA ST # 520A	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.05326	-118.25596	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42190	13041-20000-21070	1901 S AVENUE OF THE STARS STE 900	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.05949	-118.41705	Plan check for energy and emergency lighing. Commercial high-rise office. Suite 900, 9th floor. Susman Godfrey LLP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42191	10041-20000-16428	5633 W CARLTON WAY	90028	13	148-5A193 220	5544026016	R4-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			08/20/2010 12:00:00 AM	08/20/2010 12:00:00 AM		Permit Finaled	08/22/2011 12:00:00 AM	ADDRESS	34.10062	-118.31267	fire alarm 17 units apartments	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42192	11041-20000-25513	14565 W LANARK ST	91402	6	189B149    17	2210011030	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.21805	-118.45109	New 194.8 KW for a roof mounted PV system for a commercial property.  Applicant s using a 100 KW and 75 KW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42193	14041-10000-00147	589 E VENICE BLVD 1st floor	90291	11	108B145  1542	4241037011	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM			PC Info Complete	01/08/2014 12:00:00 AM	ADDRESS	33.98988	-118.46173	PLAN CHECK FOR T24 ENERGY. COMMERCIAL INTERIOR TENANT IMPROVEMENT.   NO CHANGE OF USE.  <400 AMPS. 2200 SQFT. FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42194	15041-20000-20092	8900 N DE SOTO AVE Bldg 102-Floor 1&2	91304	3	195B109   476	2780001057	(T)(Q)M2-1, MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 36,440 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42195	19041-20000-40631	8510 N BALBOA BLVD #100	91325	12	192B133    87	2689019016	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.2251	-118.50158	T24 PLAN CHECK FOR TI REMODEL OF EXISTING OFFICE LOW RISE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2363 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42196	19041-10000-27450	4645 W MARWOOD DR	90065	14	159A219   112	5684027025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.13084	-118.22433	(ePlan) PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS  6.935KWdc / 6.50KWac.  PV1 SYSTEM CONSISTING OF 19 MODULES USING 19 MICROINVERTERS(ENPHASE IQ7PLUS-72-2-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42197	13041-10000-33110	10600 N KESTER AVE	91345	7	207B149   615	2648004016	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.2629	-118.45656	PV1, Install 4.25 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE3800A-US. (17)modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42198	18041-10000-38043	13536 W SATICOY ST	91402	6	186B157   141	2303024012	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.20918	-118.42823	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42199	16041-20000-28740	10787 W WILSHIRE BLVD 1-56	90024	5	132B153   181	4360004***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			08/12/2016 12:00:00 AM			PC Info Complete	08/30/2016 12:00:00 AM	ADDRESS	34.0602	-118.43932	Plan check for power only. Replacing chiller equipment and pumps. New 225.4kVA chiller and 2 new 3HP pumps. Existing service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42200	16041-30000-23405	11560 N HUNNEWELL AVE	91342	3	213B165   404	2531022033	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.28047	-118.39695	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42201	14041-20000-33182	17801 W MALDEN ST	91325	12	192B129   138	2787012010	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.22493	-118.52114	Roof mounted PV system with Enphase microinverter, model M215-60.  Total system size 6.0KW ac.Note: Solar PV installation shall comply with FPB rquirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42202	14041-10000-25475	21710 W VANOWEN ST	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.19342	-118.60185	FA FOR WEST VALLEY COMMUNITY CENTER BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42203	17041-10000-04504	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.05007	-118.2433	restaurant TI, full plan check for power and energy. place of assembly.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42204	13041-10000-21944	11285 W NATIONAL BLVD	90064	11	120B157   345	4258017003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.02652	-118.43134	TITLE-24 TENANT IMPROVEMENT FOR TWO PRIVATE OFFICES IN A SINGLE-STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42205	16041-10000-16952	8337 N LAUREL CANYON BLVD	91352	2	192B165   248	2633006019	P-1VL	North Valley	Sun Valley			1210.00	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.22287	-118.3967	TI to an (E) medical office. No surgery room.  Install new lights and receptacles.  PC for T-24 only. Total area: 3,688 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42206	19041-10000-05751	1401 E 3RD ST	90033	14	127-5A219  23	5172010002	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.0452	-118.22515	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42207	19041-10000-48841	826 N COLE AVE	90038	13	141B185   133	5533028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.08616	-118.3297	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42208	16041-20001-21222	10344 W DIAMOND ST LOT 13	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42209	10041-30000-12596	159 S LA BREA AVE	90036	5	138B181  1114	5513019005	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	10/19/2010 12:00:00 AM	ADDRESS	34.07196	-118.34423	TI in an existing commercial space. Complete Electrical Plan Check may be required subject to field inspection. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42210	15041-10001-29378	2051 N CUMMINGS DR	90027	4	151-5A195 137	5589003014	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.10868	-118.30205	EXPEDITED RSES PLANCHECK PER APPLICANT REQUEST.<<<PV1 ADDITION 2.280 KW DC SOLAR ARRAY TO AN EXISTING 7.350 KW DC SYSTEM ON  A SINGLE FAMILY HOUSE. (8) MODULES: SOLAR WORLD SE 285 MONO (8)  ENPHASE M250-60-2LL-S22>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42211	17041-10000-11202	10250 W SANTA MONICA BLVD UNIT 1912	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Info Complete	04/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check (power+energy) for ""hpe"" , 1st time tenant at Westfield Century City. Total area 828 sq.ft*DB ELA43"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42212	15041-10000-17883	3970 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   606	5032007022	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.015	-118.34242	Replacing a whole new fire alarm system for a single story commercial building; Scope includes (1) new fire alarm panel, (1) annunciator control panel, (1) power supply, and (74) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42213	15041-10000-28875	2585 S SEPULVEDA BLVD	90064	5	123B153   502	4256012009	R3-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.03312	-118.43279	NEW FIRE ALARM SYSTEM 22 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42214	14041-20000-15832	1420 W JAMES M WOOD BLVD	90015	1	129A205    23	5137005020	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	PIN	34.04950988	-118.27098288	Plan check for energy only. 2-story office building. New lighting (incl. Emergency) in basement, also replace some existing lighting in basement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42215	18041-10000-31591	216 W MANCHESTER AVE	90003	8	097-5A203 350	6040013007	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	33.95992	-118.27666	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42216	16041-10000-00047	12746 W JEFFERSON BLVD	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	33.97756	-118.41709	TI, added new lighting fixtures on existing commercial build. STE 1100 Whole Foods Market #69.PC for Energy only. Area; 3050sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42217	17041-10001-42783	443 S SAN PEDRO ST	90013	14	127-5A213 105	5148011018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	34.04477	-118.24374	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED. CHANGES INCLUDE REVISING LOAD CALCULATIONS AND SINGLE LINE DIAGRAM DUE TO FOUR FUTURE ADDITIONAL APARTMENT UNITS AND HOUSE PANEL LOADS. APPLICANT IS REQUESTING MASTER PLAN CHECKER DIAN MARTINEZ. (((((((PC FOR SERVICE UPGRADE FOR EXISTING COMM. BUILDING WITH DWELLING UNITS. (POWER ONLY)SERVICE SIZE RATED AT 2000A 120/208VSCOPE INCLUDES NEW SERVICE GEAR AND 2 RESIDINTIAL DIST. BOARDS.ALL DWELING UNITS PANELS TO BE UNDER A SEPERATE PERMIT AND ARE FOR REFERENCE ONLY!BUILDING APP#17016-10000-32478	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42218	18041-10000-31485	2517 S 12TH AVE	90018	10	123B185   512	5059007013	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.02	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	12/01/2018 12:00:00 AM	ADDRESS	34.03376	-118.33095	PLAN CHECK FOR 7.6KVA SYSTEM CONSISTING OF 25 SOLAR MODULES WITH P400 POWER OPTIMIZERS, AND TESLA BACKUP BATTERY SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42219	15041-20001-39123	10621 N FULLBRIGHT AVE	91311	12	207B113   138	2707018016	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.26291	-118.57694	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac/11.395KWdc. (43) MODULES-KYOCERA #KU2656ZPA(43)SOLAREDGE #P300 OPTIMERS(1) INVERTER-SOLAREDGE #SE10000A-US-ZB-U	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42220	12041-10000-16581	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	Plan check T24 Energy/Emergency lighting Nordstrom Ebar suite #10B in Building Q. Include sign exterior lighting. Sign Permit under#12048-10000-02287	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42221	15041-20000-17098	1241 S SOTO ST Ste 121	90023	14	121-5A221 147	5170017030	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			Reviewed by Supervisor	06/09/2015 12:00:00 AM	ADDRESS	34.02743	-118.21975	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,700 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42222	15041-20000-42334	423 N ARBRAMAR AVE	90272	11	126B125   601	4413008009	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.04094	-118.53666	Plan check for a PV1 roof-mounted PV system. System size is 15.4 kWac and consists of (2) inverters, (48) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42223	15041-20000-28529	14015 W VENTURA BLVD	91423	4	165B153   422	2271014013	C2-1VL, R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.14929	-118.43784	"Title 24 plan check only.  Total area = 4,018 sq. ft.  T.I. to existing restaraunt space.  369 A load.  New lighting, recepticles, and equipment.""COMPLY WITH DEPARTMENT ORDER effective date 02/10/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42224	14041-20000-20088	22700 W COVELLO ST	91307	12	186B097   362	2022010005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.20724	-118.62134	PV1Central Transformerless inverter standard plan.Install roof-mounted solar array on SFD. System size: 6kW.(2) Power-One PVI-3.0-OUTD-S-US-A transformerless inverters(26) REC Solar REC260PE(BLK) pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42225	16041-10000-15463	3650 W MARTIN LUTHER KING, JR BLVD SUITE 187	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	PC FOR ENERGY ONLY. T.I FOR TIME WARNER CABLE. TRANSFER FROM RETAIL TO TIME WARNER CABLE. TOTAL AREA 3965 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42226	11041-10000-21981	6303 N OWENSMOUTH AVE 8TH FL	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	TENANT IMPROVEMENTS IN OFFICESPLAN CHK IS FOR TITLE AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42227	17041-90001-08360	1241 W 54TH ST	90037	9	108B197   504	5002006005	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM			PC Approved	04/11/2018 12:00:00 AM	ADDRESS	33.99333	-118.29739	PC for 7.6kW(ac) roofmounted solar system. Installing 29 modules (8.12kW(dc)) with optimizers, 7.6kW central inverter  and upgrading main panel to 200A with 200A main. Permit fees paid under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42228	18041-10000-31975	20105 W RINALDI ST BLDG S3-STE 120	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.27543	-118.57209	PLAN CHECK FOR POWER AND ENERGY FOR - TI FOR NEW PEET'S COFFEE SHOP IN EXISTING SHELL BUILDING; INSTALLATION OF NEW INTERIOR PARTITIONS, FINISHES, FIXTURES, FURNITURE, CASEWORK, MILLWORK, EQUIPMENT, AND MODIFICATION TO EXISTING STOREFRONT - TOTAL AFFECTED AREA = 1814 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42229	18041-20000-09163	7852 N FAUST AVE	91304	12	189B097   706	2013029011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.2135	-118.62026	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac/8.265 kWdc and consists of (1) inverter and (29) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42230	16041-20000-32388	12980 W CORCORAN PL	91340	7	216B161   138	2514010054	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.28914	-118.41572	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP., STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42231	14041-10000-23265	928 S WESTERN AVE	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.05485	-118.30886	Fire alarm system for T.I in a commercial building with 573 alarm devices and a fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42232	19041-10000-41886	207 N VERMONT AVE	90004	13	138B197   624	5518033019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2112.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Info Complete	12/13/2019 12:00:00 AM	ADDRESS	34.07477	-118.29189	POWER PLAN CHECK FOR A NEW 800A 208/120 3PH 4W SERVICE IN AN EXISTING 2-STORY RETAIL/OFFICE BLDG.  SCOPE OF WORK COVERS EQUIPMENT, ELEVATOR AND HVAC. ALL FUTURE TENANTS IMPROVEMENT SHALL BE PERMITTED SEPERATELY. B#19014-10000-03586	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42233	19041-10000-07897	1053 S CRENSHAW BLVD	90019	10	129B189    95	5082027025	C2-1-O	Central	Wilshire	Olympic Park		2127.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.05336	-118.32396	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42234	16041-20000-30555	7828 N OWENSMOUTH AVE	91304	3	189B105   398	2110006003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Issued	08/26/2016 12:00:00 AM	ADDRESS	34.2128	-118.6015	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42235	18041-20001-13406	13415 W ERWIN ST	91401	2	177B157   372	2330005023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.18315	-118.42522	Fees for expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42236	15041-20000-40832	13204 N AZORES AVE	91342	7	225B157   786	2512012040	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.31029	-118.42255	PV1, roof mounted solar 6kW AC, interconnect with (E) 200A service.(26) hanhwa q cell Q PRO G4 260(1) SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42237	16041-20001-10186	4675 N GALENDO ST	91364	3	166-5A105  98	2171024063	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	34.15144	-118.60088	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.76 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42238	14041-10000-15461	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	PLANCHECK FOR T24 ENERGY. SIGN LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42239	14041-10000-17756	1225 N VERMONT AVE	90029	13	144B197   154	5540017802	[Q]C2-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Verifications in Progress	05/26/2017 12:00:00 AM	ADDRESS	34.09418	-118.29209	PLANCHECK FOR POWER AND ENERGY. 24 UNIT RESIDENTIAL WITH 7 RETAIL UNITS.  7 TYPICAL RESDIENTIAL UNITS. DUE TO PLAN CHECK EXTENSIONS, ALL CODE CYCLES SHALL FOLLOW 2017 STANDARDS.  BUILDING P#:  07010-10001-04348  PLAN CHECK EXTENSION. RETAIL/OFFICE/APARTMENT. SUPPLEMENTAL TO 07010-10000-04348	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42240	15041-10000-01456	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	Removal of (E) 3000A busway - connected loads to be transferred to (E) 1600A busway.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42241	19041-10000-18980	3838-3846 S CLARINGTON AVE	90232	5	120B165  1354	4207005019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM			Reviewed by Supervisor	05/28/2019 12:00:00 AM	ADDRESS	34.02159	-118.39945	FULL PC (POWER AND ENERGY) FOR  NEW 3-STORY TYPE VB COMMERCIAL BUILDING, SERVICE SIZE IS 1600A,480/277V, 3PH,4W.  2-STORIES OFFICE (B-OCCUPANCY) OVER 1-STORY ON GRADE PARKING (S2-OCCUPANCY) PODIUM. AREA OF SCOPE 18,288SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42242	12041-20000-09589	18949 W MAYALL ST	91324	12	204B121   389	2729003034	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.25376	-118.54661	Roof mount 6.2KW PV system with microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42243	15041-20000-37144	12330 N EL ORO WAY	91344	12	219B133   553	2608022019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.41	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM			Reviewed by Supervisor	11/17/2015 12:00:00 AM	ADDRESS	34.29483	-118.50466	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8 KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42244	14041-20001-26993	2415 E 15TH ST	90021	14	120A217   231	5168010006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.02106	-118.22952	PERMIT UNDER APPLICATION# 14041 10000 26993.  FIRE ALARM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42245	10041-20000-02490	6752 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	04/08/2010 12:00:00 AM	ADDRESS	34.11851	-118.34078	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42246	16041-10000-43913	725 S FIGUEROA ST #1020	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check Title 24 only in existing high-rise building office T.I. Total area: 4,089  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42247	17041-10000-40268	17134 W OTSEGO ST	91316	5	171B133   494	2258011011	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Issued	11/15/2017 12:00:00 AM	ADDRESS	34.16356	-118.50692	NEW BATTERY BACK SYSTEM TO AN EXISTING  RESIDENTIAL BUILDING. 3.6KW BATTERY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42248	19041-10001-17378	18915 W SUPERIOR ST	91324	12	201B121   449	2762039016	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM			PC Approved	05/24/2019 12:00:00 AM	ADDRESS	34.2465	-118.54541	EXPEDITED PER APLICANT REQUEST ((PV1. NEW SINGLEFAMILY ROOFTOP SOLAR SYSTEM WITH TESLA POWERWALL. SYSTEM CONSIST OF 3000 SQ.FT OF INTEGRATED ROOFTILE SOLAR PANELS, THREE CENTRAL INVERTERS ( DELTA SOLIVIA 5.2, 5.2, 3.8), AND TWO TESLA POWERWALL BATTERIES. SYSTEM SIZE IS 16.38KWdc AND 14.2KWac))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42249	11041-20000-14986	1122 W WASHINGTON BLVD	90007	1	126A201   241	5135014042	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	PIN	34.03848469	-118.28242224	PLAN CHECK T24 ENERGY FOR PEP BOYS OFFICE BUILDING INTERIOR TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42250	18041-20000-19698	3727 N MEADVILLE DR	91403	4	162A145   151	2279004016	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.13746	-118.46673	Plan check for PV roof mounted system, System size: 10kW with 35 modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42251	18041-20000-39544	12338 W VENTURA BLVD	91604	2	162B165   263	2369002022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.14278	-118.40219	ti to an existing commercial building.  adding new lightinng new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42252	12041-20000-21742	11250 W OLYMPIC BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.03831	-118.44057	Plan check for power and energy. Michael's. 21655 indoor sqft. Fire Alarm Plans will be a future submittal. 3-story commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42253	19041-20001-31965	8744 N REMMET AVE	91304	3	195B105   184	2779041034	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.22948	-118.60011	PV3.  Install 22.57 kW grid tied PV system on carport.  (74) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42254	13041-10001-20342	1420 S FIGUEROA ST	90015	9	126A205   176	5134009019	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			02/06/2014 12:00:00 AM			PC Info Complete	04/03/2014 12:00:00 AM	ADDRESS	34.03815	-118.26937	CHANGES TO APPROVED: CHANGES REFLECT what is installed in the FIELD.  Feeder lengths changed, fire pump conductor now concrete encased, and load calculations updated.  Delat 3 only under this submittalpermit is existi ng, this is a plan check onlyoriginal description:pc for power and energy.  METHANE Zone. PROPOSED  193 UNIT APARTMENT AND PARKING GARAGE. 7 STORY (5 LEVELS OF TYPE IIIA APARTMENT OVER 2 LEVELS OF TYPE I , APARTMENT AND PARKING OVER 2 LEVELS OF BASEMENT PARKING.[][][conduit variance filed and paid for on 10/11/2013 under 13041-10000-28450 . pl,10-11-13[][][	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42255	17041-20000-00961	400 S GRAND AVE	90071	14	130-5A211  70	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05136	-118.2525	two story addition to an existing high rise building, for new (2) 4160V services and optional standy equipment.  plan check for power and energy.2014 energy standards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42256	15041-10000-14400	1225 N CYPRESS AVE	90065	1	147A217   298	5454027039	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM			PC Approved	05/12/2015 12:00:00 AM	ADDRESS	34.09585	-118.22841	PC FOR T24 ONLY. MIXED USED BUILDING. TWO STORY BUILDING. TOTAL AREA 5435 SQ FT.INSPECTION FEES ARE PAID UNDER EXPRESS # 15041-10000-03687	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42257	11041-20000-25519	12312 W OLYMPIC BLVD	90064	11	123B149   659	4259025008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM			PC Approved	11/30/2011 12:00:00 AM	ADDRESS	34.03166	-118.45665	T.I.  Existing one story commerical building.  Building is occupied by HULU (Online movie streaming).  Replacing fixtures in private offices and editing room.  Plan check is for enerhy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42258	15041-10000-42517	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Expired	04/06/2020 12:00:00 AM	ADDRESS	34.07196	-118.24719	pc for upgrade distribution equipment. adding 2 firepumps and supply from medium voltage switchgear. reconnected existing equipment and lighting for fire pump room. pc for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42259	18041-10000-15213	100 WORLD WAY BHS	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	02/17/2021 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE AND TI OF SPACES WITHIN T1 ARRIVALS LEVEL TO EXPAND CHECKED BAGGAGE INSPECTION SYSTEM (CBIS) AND CHECKED BAGGAGE RECONCILIATION AREA (CBRA); BUILDING PERMIT # 18016-10000-10246	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42260	11041-20001-19999	8928 N SEPULVEDA BLVD	91343	7	195B145   150	2654005015	M1-1	North Valley	Mission Hills - Panorama City - North Hills			1175.10	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	02/08/2013 12:00:00 AM	ADDRESS	34.23317	-118.46736	PLAN CHECK ONLY TO APPROVED SET OF PLANS. CHANGE OF BREAKER RATINGS.PLAN CHECK POWER AND ENERGY FOR 2-STORY NEW OFFICE BUILDING WITH 800A SERVICE. PLAN CHECK DOES NOT INCLUDE 8938 N. SEPULVEDA BLVD BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42261	16041-20000-40161	11601 N DE CELIS PL	91344	12	213B137   418	2610011008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.28107	-118.49626	Plan check for the addition of a PV system onto an existing PV1 roof-mounted PV system. System addition size is 3 kWac for a total system size of 6 kWac. System addition consists of (1) inverter, (14) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42262	16041-10000-44573	2302 N RIVERDALE AVE	90031	13	144B213   601	5445019029	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.09041	-118.23526	PC for energy only. Remove HID Fixtures and replace with New LED fixtures. Outdoor Ttile 24. Area: 3500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42263	15041-10001-43037	1321 E PALMETTO ST	90013	14	126A217    38	5164003012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	ADDRESS	34.04034	-118.23199	03/14/16Changes to an approved set of plans. Changes are made under delta 13. Changes include replacing lighting fixtures with track mounted led lights. NOTE: PERMIT PULLED UNDER PCIS#15041-10000-43037((Ti to existing offices, pc for energy only. Adding new lighting and receptacles. Total sq ft =1292	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42264	14041-20000-24378	22620 W MIRANDA ST	91367	3	174B097   295	2040007011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.17455	-118.61981	PV1.  Install 9.72 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42265	14041-20000-03571	447 N MESA ROAD	90402	11	123B129   383	4410016032	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.03376	-118.51663	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING ENPHASE M215 MICROINVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42266	12041-20000-13166	15211 W SHERMAN WAY 1-99	91405	6	183B145   784	2221019117	R1-1, R3-1, R3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	ADDRESS	34.20144	-118.46442	Install emergency lighting in all corridors of the a high rise building.  Plan check for energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42267	17041-20001-13425	2535 N CARMAN CREST DR	90068	4	153B181   238	5572009024	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.11506	-118.34821	7/31/17changes to an approved set of plans.  changes include addition of AC disconnect and rerouting of AC conduit.  (((Installation of new ground mounted solar PV array interconnected to existing single family dwelling.  Microinverter system.  Total system size = 18 kWac.     Building permit #17020-10000-00561)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42268	16041-10000-28386	17821 W LUDLOW ST	91344	12	210B129   402	2712001009	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.27111	-118.52232	PV1 roof mounted solar system installtion for a single family home. Installing a central inverter rated at 6.0Kw and 16 dc solar modules plus optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42269	12041-10000-02630	14401 W HUSTON ST	91423	4	169-5A151  41	2248007079	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Approved	02/03/2012 12:00:00 AM	ADDRESS	34.15954	-118.44639	Plan check for T24 Energy for exterior lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42270	19041-20001-04250	10245 N QUILL AVE	91040	7	204B189   746	2560022003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.25551	-118.31682	Changes to an permitted set of plans, changes include update as built to show main panel upgrade to 200A new. Plan check only. Fees $0.00 due to California Senate Bill 1222 and AB 1414(((((Plan check for PV roof mounted system and battery energy storage, PV System size: 5.85KW with 18 PV Modules and 1 inverter 5.2KW with 1 Tesla battery 13.5KWH.))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42271	19041-10000-09100	14987 W ORO GRANDE ST	91342	7	219B149   512	2604033009	RE9-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.29647	-118.45801	$0 Permit Fee per AB 1414. NEW ROOF MOUNTED 12.2KW PV SYSTEM WITH 40 PV PANEL(Q.Peak-G4.1 300-305) ON  A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42272	19041-10000-46825	1220 S SAN PEDRO ST	90015	14	123A211    33	5132012052	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Issued	11/14/2019 12:00:00 AM	ADDRESS	34.03302	-118.25357	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42273	18041-20000-25113	7012 N OWENSMOUTH AVE	91303	3	183B105   617	2138008010	P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Issued	07/05/2018 12:00:00 AM	ADDRESS	34.19776	-118.60139	PV1.  Installation of 11.4 kW roof mounted grid tied PV system.  (42) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42274	11041-20000-25040	15301 W VENTURA BLVD Bldg D-Ste 210	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.15411	-118.46654	T.I.  relocating light fixtures in Building D suite # 210 (in office and motion capture area).  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42275	18041-10000-04384	1030 N SWARTHMORE AVE #4-101B	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	Full plan check for a Take-out restaurant. Scope include new lighting and equipment. Total area is 515 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42276	12041-10000-01096	706 N CITRUS AVE	90038	5	141B185   553	5524012022	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.08374	-118.33955	Remodel of an existing 2-story commercial office building.  New 400A service, panels, and lighting.   PLAN CHECK ONLY for Energy.  NO emergency lighting.  No suite number per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42277	13041-10000-19955	9640 N OWENSMOUTH AVE	91311	12	201B105   205	2746015006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.24548	-118.60221	PV2.  Install 615.67 kW DC STC warehouse roof-mounted photovoltaic system  {Inverter: Solectria Renwables SGI-500} {2123 Modules: Talesun Solar TP672P-290}. Installation part of LADWP Feed in Tariff program.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42278	14041-10001-13198	9165 N SHARP AVE	91331	6	198B161   505	2628004022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.23576	-118.41383	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.08 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER AND TRANFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42279	11041-10000-20687	1080-1086 E ELKGROVE AVE BLDG 22	90291	11	111B145   234	4243001038	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.00273	-118.45943	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42280	11041-10000-08562	20700 W SESNON BLVD	91326	12	219B109     5	2701001039	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			PC Approved	08/15/2011 12:00:00 AM	ADDRESS	34.29545	-118.58467	out door title 24 energy. pole lights 36 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42281	13041-10000-22181	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	33.94955	-118.38342	13041-10000-22181PLAN CHECK FOR TITLE 24 PART 6 ENERGY. CLEANING AREA. CHANGES MADE TO CONTROLS. LUMINAIRES TO REMAIN IN EXISTING LOCATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42282	18041-20000-44651	13123 W HOYT ST	91331	7	207B157   159	2535022014	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Issued	11/21/2018 12:00:00 AM	ADDRESS	34.267	-118.41921	PV1.  Install 3.19 kW roof mounted grid tied PV system.  Center-fed panelboard connection.  (11) modules with 3.0 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42283	11041-10000-15250	17322 W DEARBORN ST	91325	12	198B129   389	2766012009	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	08/31/2011 12:00:00 AM	ADDRESS	34.23693	-118.51242	NEW 7.095 KW PV SYSTEM ON ROOFTOP OF SINGLE FAMILY RESIDENCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42284	19041-30000-09334	2049 S CENTURY PARK EAST 32nd Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is common area restrooms on the 32nd floor. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42285	12041-10000-30699	714 S LOS ANGELES ST	90014	14	127-5A211 193	5145002002	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.04283	-118.25069	T.I.  Existing restaurant.  New restaurant to occupy space.  Remodel of the interior.  Plan check is for Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42286	14041-20001-00123	1457 W COLORADO BLVD	90041	14	162A227   402		[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	ADDRESS	34.13954	-118.1965	(((expedite fees)))PV2 COMMERCIAL ROOF TOP SOLAR. TOTAL SYSTEM SIZE 56 MICROINVERTERS USING THE ENPHASE 250. TO BE VERIFIED WITH TEST LAB APPROVAL. TOTAL SIZE 13.4KW AC. TOTAL OF 2 SYSTEM INTERCONNECTIONS. TOTAL SERVICE SIZE IS 1200A. PLAN CHECK TO EXTEND TO ENTIRE SERVICE. use of transformer to make compatable 3phase connection	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42287	11041-20000-15968	1728 N VAN NESS AVE	90028	4	148-5A191  93	5586032016	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.10258	-118.31569	"single family solar  6.58 kw, max 3 lb per sf, inhibiting superimposed concentrated loadings and max 18"" above existing roof."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42288	18041-20000-48466	16841 W OAK VIEW DR	91436	5	168B133   412	2289018018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	PIN	34.15498235	-118.50072065	Plan check for a PV1 roof-mounted PV system. System size is 7.92 kWdc and consists of (1) 7.6 kWac rated inverter and (22) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42289	15041-10000-08840	12106 W BURBANK BLVD	91607	2	174B165   755	2347015006	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.17197	-118.39691	PC FOR POEWR AND ENERGY. NEW BUILDING FOR STARBUCKS COFFE. 3 NEW PANELS.  TOTAL AREA 10000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42290	12041-10000-19096	1250 S VERMONT AVE	90006	1	129B197  1059	5076019030	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	03/15/2013 12:00:00 AM	ADDRESS	34.04762	-118.2914	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR AUTOZONE T.I. PERMIT SHALL BE OBTAINED THRU ELECTRICAL PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42291	15041-20001-05794	1348 S BURNSIDE AVE	90019	10	129B177   828	5085036010	R3-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM			PC Approved	03/13/2015 12:00:00 AM	ADDRESS	34.04936	-118.35417	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD and detached garage, interconnect with a 200A MSP.System size: 5.76kW. Ungrounded system.(24) EnPhase M250 microinverters with (24) 275W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42292	13041-10001-05351	14141 W VENTURA BLVD #2	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	PLAN CHECK FOR REVISION TO APPROVED PLANS.  CHANGES TO LIGHTING CONTROL PANEL, SWITCHING, T24 CALCULATION, AND LOAD CALCULATION. PLAN CHECK FOR POWER AND EMERGENCY. FIRST TIME TENANT.  ISLANDS RESTAURANT. SUITE #2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42293	12041-20000-19060	12555 W JEFFERSON BLVD SUITE 150	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	33.97954	-118.41361	T.I. to exist office space suite 150.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42294	11041-10000-22284	9301 N TAMPA AVE Space #91	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM			PC Approved	10/18/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	Title 24 and emergency lighting for a low rise retail center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42295	17041-10000-16153	437 S HILL ST	90013	14	130-5A211 148	5149027013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Apartment			05/15/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.0495	-118.2514	INSTALLATION OF A NEW FIRE ALARM SYSTEM WITH 844 FA DEVICES AND 15 FA PANEL, IN A 7-STORY APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42296	15041-20000-35577	3761 N BEVERLY RIDGE DR	91423	4	162B149   408	2274016004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Closed	02/14/2017 12:00:00 AM	ADDRESS	34.13934	-118.44708	pv1 sfd total system size 6kw ac using central inverter system. using standard plan. total of 29 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42297	13041-10000-35458	2450 N ARMSTRONG AVE	90039	4	148-5A207 106	5439015006	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/23/2014 12:00:00 AM	ADDRESS	34.10097	-118.26131	PV1, Install 3.5 kw DC roof-mounted solar array, interconnect with main service for a one story house. (1)Transformerless inverter(s): SOLAREDGE SE 3800A-US, (14)Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42298	11041-10000-26912	5651 N SEPULVEDA BLVD	91411	2	174B145   321	2243002017	CM-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.17358	-118.46646	New 3-story medical and office building with surgery rooms.  New 2,500A service, sub panels, emergency generator, circuits and lighting.  Full plan check.  Applicant does not have T-24 outdoor area, additional fees will need to be collected for outdoor T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42299	14041-20000-11586	2114 W COLORADO BLVD	90041	14	162A223   124	5686003016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.13895	-118.21249	TI for (E) retail commercial space with (E) 100A service.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42300	19041-20000-35975	1426 N FULLER AVE	90046	4	147B181   824	5548019011	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			09/12/2019 12:00:00 AM			PC Info Complete	09/25/2020 12:00:00 AM	ADDRESS	34.09671	-118.34942	1000A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42301	13041-20000-14244	14006 W RIVERSIDE DR #114	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	Change to lighting and receptacles in an existing retail space #114 at Westfield Fashion Square.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42302	18041-10000-41996	21201 W VICTORY BLVD	91303	3	180B105    49	2148031014	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.18856	-118.59447	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42303	18041-10000-48894	22015 W TULSA ST	91311	12	207B101   587	2723005064	(T)(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Issued	01/08/2019 12:00:00 AM	ADDRESS	34.26706	-118.60723	NEW ROOF MOUNTED 15.12 KW(DC) PV SYSTEM CONSISTING 42 PV MODULES AND 2 INVERTERS (SE7600H-US & SE6000H-US)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42304	14041-10000-35214	14006 W RIVERSIDE DR # 210	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Enery plan check with Tailor Method for a retail store located inside a mall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42305	19041-20000-27094	11679 N FLORENCIA WAY pv1	91326	12	216B109    93	2701076063	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Issued	07/16/2019 12:00:00 AM	ADDRESS	34.28457	-118.58523	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.(2) tesla ESS rated at 5KW each.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42306	14041-20000-18129	11036 N BABBITT AVE	91344	12	210B133   519	2696007005	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.2712	-118.50966	"PV1.  Install 10.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.""COMPLY WITH DEPARTMENT ORDER effective date02/18/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42307	11041-20001-14068	11378 N EL DORADO AVE	91340	7	213B153   205	2616018030	M1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	08/08/2011 12:00:00 AM		Permit Finaled	08/12/2011 12:00:00 AM	ADDRESS	34.27686	-118.43625	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING. PERMIT FOR 4 ADDITIONAL CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42308	09041-30001-22032	5901 W OLYMPIC BLVD #100	90036	4	132B177   666	5086024025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM			PC Approved	02/11/2010 12:00:00 AM	ADDRESS	34.05771	-118.35996	"2-11-10 - Supplemental is for changes to lighting plan.  P/C is for Energy only :: TI in an existing occupancy in Suite #100 ""Olympia Cafe"".  Plan Check is for title 24 and emergency lights."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42309	16041-10000-25339	5449 W HOLLYWOOD BLVD	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.10193	-118.30856	INTERIOR TI  OFFICE SPACE. new lighting. pc for t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42310	17041-20000-09611	12827 W RANGOON ST	91331	6	198B161   321	2629027012	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	10/02/2023 12:00:00 AM	ADDRESS	34.2376	-118.4132	Plan check for power and energy. Project site is an existing commercial building (H-3 occupancy). Project scope is the installation of a generator and new load on existing distribution equipment. Total lighting area = 3,817 sq. ft.Note: Building application has been generated under 17016-20000-06971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42311	17041-10001-00820	11211 S LA CIENEGA BLVD	90045	11	087B173    85	4129038024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	33.93287	-118.37022	$0 Fee department error for change fo address. PC for change to approved set. Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42312	13041-20000-15077	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Expired	08/12/2015 12:00:00 AM	ADDRESS	34.05373	-118.26606	PLAN CHECK FOR HIGHRISE MEDICAL OFFICE BUILDING FOR ELEVATOR UPGRADE AND UPGRADE LIGHTS IN THE PIT. 584 SQRFT T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42313	14041-20001-11075	7900 N BALBOA BLVD BLDG N	91406	6	189B133   403	2205006902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.21347	-118.50092	Change to approved set of plan. Changes include remove EXO T, S,R, Q  for MSB-M and replace with Future panels. Remove EXO P,K,O for MSB-N and replace with Future panels. Add 13 panels on Panel M. Add 12 panels to Panel N.  [[[[[PC FOR NEW SERVICE. BUILDING N. NEW 800A. ALL LOADS FUTURE. THIS IS PLAN CHECK FOR SERVICE ONLY.]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42314	16041-10000-11803	5918 N FIGUEROA ST	90042	1	151-5A229 114	5492015028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.11065	-118.19026	PC FOR ENERGY. T.I FOR A FASTFOOD RESTURANT. TOTAL AREA 582 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42315	19041-20000-44627	11820 N DORAL AVE	91326	12	216B117   106	2822006007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.28793	-118.55201	PV1. INSTALL 10.24 KW DC PV SYSTEM WITH (32) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42316	11041-10000-20284	9225 S AVIATION BLVD	90045	11	093B173    59	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	33.95196	-118.37721	61 kw photovoltaic system on the roof of two adjacent buildings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42317	13041-20000-18374	1601 S MAIN ST	90291	11	106-5A145   3	4238014017	C2-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Closed	01/23/2018 12:00:00 AM	ADDRESS	33.98776	-118.47116	Plan check for power and energy remodel of commercial space. Load is over 400A. Methane zone. Use of space will be movie studio headquarters. Silver Pictures Entertainment. Fire alarm is existing per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42318	15041-10000-35747	4226 E DIVISION ST	90065	1	154-5A221 389	5475002020	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.11595	-118.21996	PV1, ROOF MOUNTED SYSTEM USING MICROINVERTER. TOTAL SIZE 7.6KW. (32) MODULES AND (32) MICROINVERTERS. (32) SW 285 MONO (32) ENPHASE 250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42319	14041-10001-35156	1656 W 36TH PL	90018	8	120B193  1423	5041022014	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	34.02178	-118.30766	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 2.805 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(11) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42320	11041-20000-21024	6420 W WILSHIRE BLVD 19th floor	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/04/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I.  Remodel of existing office space on the 19th floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42321	19041-20001-01010	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.04538	-118.26335	02/27/2019 Changes to an approved set of plans. All changes have been clouded. Lobby lighting has been rewired and plans have been revised to show field installation.*****Original Work Description*****Renovation to (E) 5-story commercial building elevator lobbies from first floor mezzanine to fifth floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42322	13041-20000-10769	700 W CHILDS WAY 3rd floor	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.01978	-118.28463	"13041-20000-10769Historic Building.  Remodel to an existing office building, low rise.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42323	14041-10001-03159	12022 W RIALTO ST	91352	6	192B165   295	2633011005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.22421	-118.39429	Modification to approved set, relocation of service equipment and rooftop conduit run.  Approved plans to meet as-built design per inspector request.(((PV1 3KWdc. 240V. microinverter. STD. 1story. Roofmount. [(12) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(12)modules: {Renesola {JC250M-24/BB}}] )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42324	12041-10000-25593	10141 N CREBS AVE PV1	91324	12	204B121   327	2729009004	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.25452	-118.54371	PV1- NEW 8.1KW ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42325	14041-10001-14689	621 S WESTERN AVE # G-03	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.0628	-118.30928	changes to permitted set of plans-load on  Dp revised; lighting system revised to lower wattageALL CHANGES ARE CLOUDED ON THE PLANSPLANCHECK FOR POWER AND ENERGY FOR SUPER H-MART. TENANT IMPROVEMENT. EXPANDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42326	19041-20000-37183	18024 W VENTURA BLVD	91316	5	171B125   503	2181001005	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Closed	02/25/2021 12:00:00 AM	ADDRESS	34.1646	-118.52527	New 400A 240/120V 1ph-3w service, distribution, power, and lighting for (E) building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42327	18041-10000-32767	7932 N HASKELL AVE	91406	6	189B141    96	2206001010	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.21491	-118.47476	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42328	12041-10000-16884	1501 S LA BREA AVE	90019	10	129B181  1116	5070019021	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			PC Approved	07/19/2012 12:00:00 AM	ADDRESS	34.04674	-118.34531	New lighting and circuits to an existing retail space.  Load is less than 100Amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42329	14041-20000-30023	2514 N COMMONWEALTH AVE	90027	4	154-5A201 164	5592018012	RE11-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.11631	-118.28574	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.04 DC.(31) CANADIAN SOLAR CS6P-250P(14) CANADIAN CS6P-235PX(1) SOLAREDGE SE10000US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42330	19041-10000-47134	6031 N FULCHER AVE	91606	2	177B173  1007	2337004008	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.18031	-118.3733	NEW ROOF MOUNTED 5.92KW PV SYSTEM WITH 16 @ 370W AC-PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42331	17041-20000-45948	8620 N VAN NUYS BLVD A	91402	6	192B149    19	2638001038	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	34.22673	-118.4495	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor only.  partial permit fees paid under application number 17041-20000-43029	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42332	16041-20001-21819	7952 N VAN NUYS BLVD	91402	6	189B149   634	2212028020	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM			PC Approved	10/28/2016 12:00:00 AM	ADDRESS	34.21568	-118.44851	Revisions to approved set of plans.  Equipment layout changes.  (((Plan check Title 24 only in exiting space T.I. Blaze pizza  Total area: 2,245)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42333	15041-20001-15454	6320 N TOPANGA CANYON BLVD Suite 1650	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Changes to approved set.  Removing safety switch from transformer secondary (conductors less than 10').Plan check for power and Title-24 (energy).  Total area = 2,794 sq. ft.  T.I. to commercial retauk first time tenant (Dejaun Jewelers).  Two new panels connected via transformer.  New lighting, recepticles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42334	13041-10000-34129	1849 E 45TH ST BLDG B	90058	9	112-5A215  40	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.0029	-118.24014	PLAN CHECK FOR EMERGENCY LIGHTING AND EXIT SIGNS ONLY PER INSPECTORS REQUEST. 2 OF 5 BUILDINGS. BUILDING B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42335	10041-10000-00912	1924 N HILLHURST AVE	90027	4	150B201   908	5590011006	C4-1D	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.10612	-118.28727	New electrical service for existing commercial building.   Plan check T-24 energy and new electrical system.  Existing circuits on tenant panels are to be transfered to new panels as units and as utilization equipment over 3 hp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42336	17041-10000-20337	1900 S AVENUE OF THE STARS 2350	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.05979	-118.41671	PC FOR OFFICE SPACE TI (HIGH RISE) FOR TITLE-24 ENEGY ONLY. SCOPE INCLUDES NEW PANELS, CIRCUITS, LIGHTS AND RECEPTACLES  TOTAL AFFECTED AREA 7725 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42337	16041-10004-44228	22255 W CHATSWORTH ST	91311	12	207B101    61	2723006026	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2017 12:00:00 AM			PC Approved	08/18/2017 12:00:00 AM	ADDRESS	34.26453	-118.61234	CHANGES TO APPROVED SET OF PLANS - CHANGES CLOUDED ON SINGLE LINE DIAGRAM - CHANGES NCLUDE ADDITION OF PV METER. ORIGINAL PLAN CHECK 16041-10000-44228	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42338	19041-20000-50880	9626 N WHEATLAND AVE	91040	7	201B177   445	2544006053	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.24369	-118.35828	Plan check for PV roof mounted system, PV system size: 4.81kW with 13 AC Modules, existing 400 A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42339	15041-20000-27370	5408 N PENFIELD AVE	91364	3	171B113    50	2164003024	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Expired	09/15/2017 12:00:00 AM	ADDRESS	34.16852	-118.5683	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42340	14041-20001-12378	15600 W ROSCOE BLVD	91406	6	192B141   521	2654040020	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM			Reviewed by Supervisor	06/24/2014 12:00:00 AM	ADDRESS	34.2212	-118.47229	PLAN CHECK FOR POWER ONLY - Energy under master permit.Single story commercial building. Extending existing branch circuits for the installation of new lighting in a converted parking area (now a service space). Installation of one 600 amp panel and three new subpanels. Redistribution of existing loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42341	19041-10000-47092	8101 S VERMONT AVE	90044	8	099B197  1058	6033022901	C2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	05/14/2020 12:00:00 AM		Permit Finaled	01/29/2021 12:00:00 AM	ADDRESS	33.96531	-118.29201	PLAN CHECK FOR REPLACEMENT OF EXISTING MAIN PANEL FROM 400A TO 600A WITH NEW ADDED LOAD(EV CHARGERS) - SERVICE REMAINS THE SAME AT 400A, UPSIZE OF MAIN PANEL DUE TO NEW PV SYSTEM INSTALLATION UNDER SEPARATE PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42342	18041-20000-41148	17347 W SAN FERNANDO MISSION BLVD	91344	12	210B129   322	2711010015	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Re-Activate Permit	10/21/2019 12:00:00 AM	ADDRESS	34.27227	-118.51262	PV1.  Install 23.485 kW roof mounted grid tied PV system.  (77) modules with 10.0 and 11.4 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42343	16041-20000-43317	5727 N VAN NUYS BLVD bldg b	91401	4	174B149   483	2244028006	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.17462	-118.44909	ti ti an existing commercial building single story.  adding new lighing new controls to existing panels.  plan check for energy and em lighitng.  total square footage 1478.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42344	19041-20000-39570	23535 W HATTERAS ST	91367	3	174B093    69	2041004016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.17564	-118.63964	PV1.  Install 15.91 kW DC roof mounted grid tied PV system.  (43) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42345	10041-20000-05209	1591 N BEL AIR ROAD	90077	5	147B149   223	4370017025	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2010 12:00:00 AM			Reviewed by Supervisor	04/28/2010 12:00:00 AM	PIN	34.09993681	-118.44722822	NEW SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42346	11041-10000-23455	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Closed	02/25/2014 12:00:00 AM	ADDRESS	34.14246	-118.2705	Temporary  constuction service for a 4 story building (BLDG 8)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42347	17041-20002-35695	2275 N HIDALGO AVE	90039	13	147A209   201	5440006024	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	PIN	34.09715131	-118.25719039	11/29/2017 Changes to an approved set of plans. The MSP has been replaced with a solar-ready MSP which has a specified slot for solar.*****Previous Work Description*****permit fee $0.00 by state senate bill no. 1222pv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42348	15041-20001-39893	15900 W MULHOLLAND DR BUILD. 3&4	90049	5	156B141     4	4490001023	RE40-1-H	South Valley	Brentwood - Pacific Palisades	Bel Air - Beverly Crest	YES	1415.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.12665	-118.47908	3.15.2016 - Plan check for modifications to approved set. Change some loads that were shown as new back to existing. Relocate loads on panelboards. Change fixture types and update wattage on T-24 forms. Changes clouded.---Lighting and power TI of (2) upper level classroom at Milken Community shcool. The scope of work covers ADI and GFI buildings. Relocating 225A Panel Total area: 11,509sq.ft. Full PC.Build Application under B15VN16197 and B15VN16197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42349	13041-10000-32925	5110 S CRENSHAW BLVD	90043	8	111B185   564	5013019023	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	33.99629	-118.33046	Plan check for power and energy for a  MULTI-FAMILY APARTMENT COMPLEX WITH 32 UNITS.Variance is been submitted to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42350	18041-10000-44175	811 W 7TH ST 3rd Flr	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.04908	-118.25911	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 7773 SQFT AREA ON THE 3RD FLOOR.BUILDING # 18016-10000-37209	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42351	12041-20000-04428	10800 W PICO BLVD #312	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.04054	-118.4272	T.I. to existing retail space.  Install indoor general/emergency lighting with Tailor Method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42352	14041-10001-17992	607 N ARDMORE AVE	90004	13	141B193   872	5521007012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM			PC Approved	07/25/2014 12:00:00 AM	ADDRESS	34.08196	-118.30186	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42353	12041-20000-04938	3249 S LA CIENEGA BLVD	90016	10	123B173  1675	4205035001	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.02893	-118.37415	T-24 and emergency lighting plan check for change of use from (E) MANUFACTURING SPACE TO MEDIA/ENTERTAINMENT RELATED SERVICES USE, REPLACE STAIRS, AND ADD INTERIOR STRUCTURAL WALLS.  REVISION TO TENANT IMPROVEMENT UNDER PERMIT #11016-10000-17861.Existing permit 11041-20000-27139.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42354	13041-20002-32957	13280 N DRONFIELD AVE STE# 21	91342	7	225B153   556	2504018***	RD3-1-K	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.31289	-118.44322	(((3/20/2014: Changes made to approved set of plans. Removed GEC. This is a plan check only, no additional permittable items required)))PV1, Install  4 kw DC roof-mounted solar array for a 2 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 16 modules: Trina Solar TSM-250PA05.18.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42355	17041-10001-15295	10866 W ART ST	91040	7	201B173   268	2542025010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Approved	05/13/2017 12:00:00 AM	ADDRESS	34.24841	-118.36746	Expedited fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42356	17041-10001-14652	1335 S ABBOT KINNEY BLVD	90291	11	108B145  1240	4239027009	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	33.99097	-118.46678	06/16/2017Changes to an approved set of plans, changes are under Delta 4. Changes include the revision of circuits and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42357	16041-10000-27441	12364 N GLADSTONE AVE	91342	7	219B161   276	2525028006	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.29436	-118.41132	Plan chekc for T-24 only.  Remove indorr and outdoor HID fixtures and replace with new LED fixures.  Affected area: 46,591 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42358	12041-10000-08090	500 W WORLD WAY Term 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM			PC Approved	04/11/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Change of lighting in existing 'secured' areas at LAX Terminal 5.  Load is 40 Amps of load, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42359	17041-20001-20091	20332 W KESWICK ST	91306	3	186B113    98	2114002010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	34.20957	-118.57649	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12.1 kWac and consists of (35) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42360	12041-10000-15520	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Closed	12/28/2015 12:00:00 AM	ADDRESS	34.17126	-118.58861	REMODEL EXISTING BLOOD DRAW CLINIC TO EXPAND BLOOD DRAW/SPECIMEN COLLECTION IN PLACE.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42361	19041-10000-40711	2445 N MARIONDALE AVE	90032	14	139-5A237 103	5220034027	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	07/30/2021 12:00:00 AM	ADDRESS	34.07479	-118.16606	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT REMODEL OF AN EXISTING 2-STORY INTERIOR COMMERCIAL SPACE. SCOPE INCLUDE LIGHTING, RECEPTACLE AND CONTROL. TOTAL AFFECTED AREA IS 5778 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42362	14041-20001-13967	11130 N BALBOA BLVD A	91344	12	210B133   327	2682021032	C2-1VL, C4-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	34.273	-118.50196	[[[10/27/14 changes to approved set. delta 1 changes only. removing chandeliers. changes to t24 only]]]]Change of use from retail to banquet hall.    Install new branch circuits and lighting.  Plan check for power and energy.Expedite fee paid 06/03/14occupancy 984 occupant by building code permit # 14016-30000-07644	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42363	15041-20000-18913	5424 N NEWCASTLE AVE	91316	5	174B129  1006	2162009010	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.16928	-118.52418	Installation of new roof mounted solar PV array.  Total system size = 33 kWac.  Three inverter system.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42364	18041-10000-16041	1800 W 11TH ST 1-25	90006	1	129A203   119	5136020029	C1-1-HPOZ	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Apartment			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.04867	-118.27781	Plan check for a new fire alarm system for a 3-story, 25-unit apartment building . Scope include (1) fire alarm panel, (2) power sypplies, and (90) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42365	18041-10000-23867	1423 N TAMARIND AVE	90028	13	147A191   133	5545014014	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.09633	-118.31918	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALAM PANEL AND 24 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42366	19041-10000-22810	2905 W EXPOSITION PL unit 2	90018	10	117B185    13	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.02038	-118.3277	Plan check for a 3KW AC/ 2.6KW DC PV2 roof mounted system with (1) inverter and (8) modules interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42367	16041-20001-10791	5645 N FARMDALE AVE 1-10	91601	2	174B169   670	2338028004	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			05/16/2018 12:00:00 AM			PC Approved	05/16/2018 12:00:00 AM	ADDRESS	34.17328	-118.38117	Revisions to approved set of plans.  Reconfiguration of residential unit distribution: change to (2) meter boards.  Minor dwelling unit plan changes.  Approval for delta B and C revisions only.  (((PC FOR POWER AND ENERGY. NEW 44-UNIT APARTMENT BUILDING:  3-story over basement parking  4 TYPE Very Low Income Affordable Dwelling Units. TOTAL AREA 33271 SQ FT.B# 14010-20000-04022)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42368	10041-10001-09004	601 W 7TH ST	90017	14	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			PC Approved	01/07/2011 12:00:00 AM	ADDRESS	34.0475	-118.25665	REVISIONS TO APPROVED SET OF PLANS- NO NEW LOADS ARE CHANGES TO THE LIGHTONGPLAN CHK ONLYCHANGE OF USE FROM RETAIL TO RESTAURANT ( CHIPOTLE )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42369	19041-20000-38457	4847 W BEVERLY BLVD	90004	4	138B189   379	5522028042	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	04/16/2021 12:00:00 AM	ADDRESS	34.07636	-118.31517	INSTALL (102) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL FOR 4 STORY APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42370	17041-10000-08990	21019 W OSBORNE ST	91304	3	195B105    43	2779048007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.23316	-118.59132	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXURES FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 11075 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42371	14041-10000-02113	8783 W PICO BLVD	90035	5	132B169   855	4332015024	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.0549	-118.38345	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. 1489 sqft , emergency lighting.BULDING P# 13016-10000-26296.   NONSTRUCTURAL INTERIOR  TI  FOR  EXISTING  STARBUCKS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42372	16041-10004-38144	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Issued	01/23/2019 12:00:00 AM	ADDRESS	34.26153	-118.50259	Change to approved set by adding a new 1200-Amp service, single line being modified and all changes under delta-4 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42373	14041-10000-28420	921 S CROCKER ST #C05; C06;-C07	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	First tenant in renovated buildingcore and shell permitted 13041-10000-22477	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42374	13041-10000-12771	661 S HARVARD BLVD #200	90005	10	132B193    98	5093019001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	PIN	34.06123879	-118.30435379	POWER AND ENERGY FOR NEW RESTAURANT ON 2ND FLOOR IN EXISTING 2-STORY BUILDING. NEW 800A SERVICE SUPPLYING BUILDING INCLUDING EXISTING TENANT ON 1ST FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42375	14041-10000-27102	402 E RUSTIC DR	90065	1	148-5A225  16	5466015027	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.10315	-118.20764	Standard plan PV1, roof mounted system including (1) Solaredge SE5K inverter and (22) Kyocera modules and power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42376	16041-20000-23452	11159 W LA MAIDA ST	91601	2	168B173   267	2353020022	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.15886	-118.37417	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42377	15041-10000-04901	10160 N STANWIN AVE	91331	6	204B153   502	2647016017	RS-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.25553	-118.44164	Installation of new roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42378	10041-20000-18151	601 S FIGUEROA ST 41st Floor	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check T-24 energy (general/emergency) lighting on the 41st floor office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42379	15041-10000-20414	11226 W STRATHERN ST	91352	6	189B173   226	2314014046	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.21555	-118.37563	PV1, ROOF MOUNTED SYSTEM, 1-3.6 INVERTER AND 34 MODLUES. TOTAL SIZE, 8.84KW. (34) KYOCERA # KU2606XPA (1) PV1-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42380	19041-10000-14358	13326 N PASHA PL	91342	7	225B157   458	2512022036	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.3135	-118.41991	Permit fee is $0.00 due to AB1414.PV1 NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 11400H INVERTER, (1) 6000H INVERTER, AND (53) MODULES + OPTIMIZERS. TOTAL SYSTEM SIZE IS 17.4KWAC AND 19.06 KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42381	14041-10000-10030	2630 N HARLESDEN CT	90046	4	153B173    14	5569002003	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.11959	-118.36882	Per Senate Bill No.1222, Fee cap reached on  application, thus fee is $0.PV1 47.85KWdc. 240V. TRANSFORMERLESS. NONstd. 2story. Roofmount. [(174) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22-IG]}]. [(174)modules: {lg275}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42382	16041-20000-24557	2251 W HILL DR	90041	14	163-5A221  85	5671002004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.14301	-118.21503	PV1INSTALL ROOF MOUNTED PV SYSTEM TO TIE WITH EXISTING PV SYSTEM AND MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42383	11041-20000-20234	14102 W SHERMAN WAY	91405	6	183B153   149	2217022023	C1-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	11/18/2011 12:00:00 AM	ADDRESS	34.20098	-118.44032	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42384	17041-20001-01688	5716 N KELVIN AVE	91367	3	174B109   221	2151020046	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/24/2017 12:00:00 AM	ADDRESS	34.17487	-118.58647	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.15.2kW ungrounded system. (54) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42385	18041-10000-06166	12121 W WILSHIRE BLVD #205	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.04386	-118.46816	PC FOR TITLE 24 ENERGY ONLY FOR TENANT IMPROVMENT TO (E) OFFICE  (HIGHRISE).SCOPE INCLUDES NEW LIGHTS.TOTAL AFFECTED AREA 2660 SQ. FT.  B# 18016-20000-00276	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42386	17041-10000-24570	10050 S LAUREL ST 101-202	90002	15	091-5A217 109	6046019921	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	33.94629	-118.23089	POWER PLAN CHECK FOR  3-STORY, 3-UNIT APARTMENT BUILDING; SCOPE INCLDUING A 400A SERVICE AND (4) PANELS. NOTE, THIS BUILDING IS ONE OF THE (16) BUILDING ON THE SAME SITE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42387	17041-10000-03996	8500 W BEVERLY BLVD #675	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI TO RETAIL SPACE. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42388	18041-20001-32862	4327 W ADAMS BLVD	90018	10	123B185   658	5059005001	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	34.03275	-118.33285	06-20-2018 Changes to an approved set of plan, changes include update Single line diagram. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42389	17041-10003-10505	2697-2701 W JAMES M. WOOD BLVD	90006	1	132A201   169	5077025015	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.05606	-118.28673	"PLAN CHECK ONLY. DELTA ""3"" CHANGES TO APPROVED PLANS. CONNECTING THE GROUDING TO BUILDING STEEL INSTEAD OF COLD WATER PIPE AND CHANGING 200A BREAKER TYPE AT MSB TO HQR2 65K SERIES RATED. PREVIOUS SCOPE: (((DELTA ""2"" chqnges to approved plans ONLY. Changing all residential unit feeder from copper to alluminum conductors, revising load calculations due to reduction of elevator size, relocating service location, revising short circuit calculations, and relocating EV chargers on the floor plans. Note: Permit Fees are paid under PCIS#17041-10000-10505"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42390	14041-20000-29944	512 N ALEXANDRIA AVE	90004	13	141B197  1051	5520009025	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.07957	-118.2979	PV2 INSTALL ROOF MOUNTED PV SYSTEM SIZED 22 KW INTERCONNECTED WITH MAIN SERVICE PANNEL.(88) SOLARWORLD 275W(88) ENPHASE M250 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42391	18041-10001-13127	15275 W SUNSET BLVD 5-112B	90272	11	129B125   834	4423016008	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM			PC Approved	06/04/2018 12:00:00 AM	ADDRESS	34.04694	-118.52505	(THIS IS PLAN CHECK ONLY) SUPPLEMENTAL PLAN CHECK DUE TO CHANGES TO APPROVED SET FOR FIRST TIME TENANT TO EXISTING CORE AND SHELL RETAIL SPACE. SCOPE INCLUDES RELOCATING PANEL BOARD AND ADDING CIRCUITS, ADDITIONAL CIRCUITS HAS BEEN ADDED/COVERED TO PERMIT NUMBER 18041-10000-13127. CHANGES TO REFLECT AS BUILT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42392	19041-20000-04946	16830 W ESCALON DR pv1	91436	5	162B133    77	2287001003	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.14343	-118.50006	pv1install roof mounted pv system sized 10KW AC interconneted with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42393	15041-10000-25859	6330 W SAN VICENTE BLVD 5TH FLR	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.06116	-118.36804	TI ON EXISTING COMMERCIAL OFFICE BUILDING. PC ENERGY ONLY FOR 5TH FLOOR CORRIDOR AND RESTROOMS. TOTAL AREA = 1403 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42394	17041-10001-36799	1060 W EXPOSITION BLVD	90037	8	117B197   516	5037015030	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM			PC Info Complete	01/24/2019 12:00:00 AM				Supplemental plan check for power only and permit due to additional receptacle units and additional branch circuits. Scope consists of adding receptacles on existing circuit and adding 4 new branch circuit for general purpose receptacles. Changes are noted under Delta-B17<<PC FOR FIRST TIME TENANT MEDICAL TI  AN **OSHPAD-3**  CLINIC .SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTINGTOTAL AFFECTED AREA 4660 INDOOR AND ?? OUTDOOR (PLANCHECKER TO VERIFY OUTDOOR)B# 16010-10001-04056>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42395	11041-20000-15337	12700 W SHERMAN WAY	91605	2	183B161    60	2324006027	C2-1VL	South Valley	North Hollywood - Valley Village			1233.03	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	01/05/2012 12:00:00 AM	ADDRESS	34.20103	-118.40985	Ti in a dental office. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42396	12041-20000-08268	7679 N SAN FERNANDO ROAD	91505	2	186B177   564	2466036***	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM			PC Approved	04/11/2012 12:00:00 AM	ADDRESS	34.20829	-118.35559	TI of a of an office space. Plan check for energy and emergency lighting. 4853 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42397	18041-10000-04134	783 W GATUN ST 520	90731	15	021B197  1087	7445002***	[T][Q]RD1.5-1	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.75748	-118.29434	PC for 3kW(AC) PV solar roofmounted system. Installing 8 modules(2.4kW DC)with optimizer and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42398	14041-10000-19974	1338 S ABBOT KINNEY BLVD	90291	11	108B145  1340	4238004039	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM			PC Approved	07/24/2014 12:00:00 AM	ADDRESS	33.99075	-118.46691	Title 24 plan check only.  Total area = 3,474 sq. ft.Non structural interior tenent improvement at existing retail space to convert flower shop to clothing store. Add non bearing parition walls gaurd railing at (e) 2nd floor. No change in parking	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42399	19041-10000-42255	4672 E YORK BLVD 2ND FLR	90041	1	156A223   136	5474018036	RD3-1, [Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.12269	-118.21421	Plan Check for 1st time T.I  with power & Energy. Installing Panels, Circuits & Lights. Affected area: 2,536 SFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42400	13041-10000-14397	621 S WESTERN AVE # 303	90005	10	135B193   955	5503031004		Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TIME TENANT IN COMMERCIAL SPACE-GANG JUNG RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42401	16041-20001-05132	22601 W SANTA SUSANA PASS ROAD	91311	12	210B101    11	2723002018	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM			Verifications in Progress	06/20/2018 12:00:00 AM	ADDRESS	34.27227	-118.6163	[[ 6/7/16 CHANGES TO APPROVED SET. ADDITION OF A DEMAND RESPONSE BATTERY STORAGE SYSTEM ( 100KWH) TO A GROUND MOUNTED PV CARPORT SYSTEM]]]]PV2.  GROUNDMOUNTED SOLAR SYSTEM. CARPORT. SYSTEM SIZE: 400KW. 1292 MODULES11 INVERTERSFIRE APPROVAL NOT REQUIRED PER APPLICANT.BUILDING PLANCHECK : 16010-20000-01475	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42402	13041-10000-23453	840 W 34TH ST	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	PIN	34.02192429	-118.28551249	Alteration of existing storage room into 2 seperate new storage rooms in Albert S. Raubenheimer Music Faculty Memorial Building.  Title 24 plan check for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42403	17041-10000-11356	625 S LA FAYETTE PARK PL	90057	10	135A201   216	5077006900	OS-1XL	Central	Wilshire	MacArthur Park, Rampart Village, Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Closed	07/17/2020 12:00:00 AM	ADDRESS	34.06184	-118.28322	PLAN CHECK FOR THREE STORIES PERFORMING ARTS CENTER. NEW BUILDING MADE FROM MODULAR STATE APPROVED SHIPING CONTAINERS.  PLAN CHECK FOR POWER(DISTRIBUTION EQUPMENT) AND OUTDOOR ENERGY ONLY. TOTAL SQ. FT. 74324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42404	18041-20002-15813	9540 N VASSAR AVE	91311	12	201B105   236	2746016055	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.24413	-118.60451	08-13-2019 Changes to an approved set of plan, Changes include update existing donduit and conductor size on the plan, update fault current calculation and AIC rating. Changes has been clouded as delta 2 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42405	11041-20000-05317	11611 W SAN VICENTE BLVD 8th floor	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM	03/17/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	energy plan check 8th floor cooridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42406	19041-10000-02429	1055 W WILSHIRE BLVD SUITE 1200	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.05232	-118.2629	T24 FOR EXISTING OFFICE SPACE, TOTAL SQUARE FOOTAGE = 16,715Bldg Permit: 18016-10000-41199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42407	19041-10000-26845	2130 E VIOLET ST	90021	14	123A217    90	5166004027	(T)(Q)M3-2D-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	09/18/2020 12:00:00 AM		Permit Finaled	04/19/2023 12:00:00 AM	ADDRESS	34.03235	-118.22885	Full plan check for a new core and shell 9-story mix-used high-rise commercial building. Scope inlcude (1) 5000-Amp service 277/480v with all new equipment and a total lighting area of 207,208-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42408	10041-10000-23530	732 E 10TH ST # 102	90021	9	124-5A211 195	5132011030	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	12/22/2010 12:00:00 AM	ADDRESS	34.03504	-118.25099	First tenant in retail space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42409	14041-10000-18060	9500 N RESEDA BLVD	91324	12	198B125    37	2764008019	C2-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.2431	-118.53588	Title 24 plan check only.  Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42410	16041-10000-45636	4938 N EDGERTON AVE	91436	5	168B137   192	2260008007	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.15943	-118.48894	PC FOR SFD ROOF MOUNTED PV SYSTEMSYSTEM SIZE 11.4KW (AC)INCLUDING 3 STRINGS WITH OPTIMIZERinverter --> solar edge se11400a-us optimizer--> solar edge p400module--> solar world sw 340 xl mono	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42411	19041-10000-17593	1300 E 50TH ST	90011	9	111A211   346	5107032012	RD2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.20	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	33.99739	-118.25193	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42412	15041-20000-39958	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011065	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	33.98179	-118.40283	Plan check for power and energy. Project site is an existing commercial building. Building will be used as a pet care/adoption facility with office space. Project scope is a first-time tenant. Total lighting area = 35,807 sq. ft.Note: Building application for first time tenant has been submitted under 15016-10000-25722. Building application for core-and-shell is under 13010-10000-04241.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42413	15041-20000-20580	13233 W OTTOMAN ST	91331	6	195B157   214	2627014019	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.23376	-118.42138	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.Note: Permit fees have already been paid under application 15041-90000-16052. This application is for plan check only.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42414	17041-10000-19068	444 S FLOWER ST 300	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	Title 24 plan check.  T.I. to convert storage space to office in existing commercial highrise building.  One new subpanel with lighting and receptacle loads.  Total area = 1,215 sq. ft.       Building permit #17016-10000-03689       Electrical permit #17041-90000-16067	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42415	19041-10000-33230	19191 S VERMONT AVE STE 225	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	33.85656	-118.29099	Plan check for energy only, Interior, non-structural tenant improvement to office suite on 2nd floor.  Scope of work to include installation of new lighting and receptacles. Total sq. ft. 6100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42416	13041-10002-23151	380 WORLD WAY 6C2-10	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	11/13/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	CHANGES TO THE ORIGINAL PERMITTED SET OF PLANS-LUMINAIRES TYPE AND QUANTITY   HAVE CHANGED REQUIRING PLAN CHK ONLY FOR TITLE 24; TYPE OF CONDUIT USED INCLUDE ON THE SINGLE LINE DIAGRAM ((((((((FIRST TIME TENANT AT LAX TBIT. EMIRATES LOUNGE. 4 PANELS 1 75 KVA TRANSFORMER. PLAN CHECK FOR POWER AND TITLE 24 PART 6 ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42417	19041-20000-51590	5113 S BABETTE AVE	90066	11	105B161   549	4221011071	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Expired	09/11/2023 12:00:00 AM	ADDRESS	33.98478	-118.41681	PV1. INSTALL 6.72 KW DC PV SYSTEM WITH (21) MODULES/OPTIMIZERS AND (1) INVERTER(SE6000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42418	15041-10000-42376	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Closed	12/16/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	TEMP POWER FOR CONSTRUCYION SITE 1600AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42419	14041-20001-21604	16254 W LOS ALIMOS ST	91344	12	207B137   381	2680008023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.26547	-118.48661	Fee for expedite only.*****Roof mounted PV system with system size 8.16KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42420	17041-10001-27724	8119 N GEYSER AVE	91335	12	189B121    68	2103002030	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.21805	-118.54281	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42421	16041-10001-06864	1218 W VENICE BLVD	90006	1	127-5A201 321	5135011020	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM			Corrections Issued	08/04/2016 12:00:00 AM	ADDRESS	34.04245	-118.28145	8/4/16 All changes are made under delta 1 and delta 2. CHanges include adding and replacinglighting fixtures, adding occupancy sensors, removing the time clock. T-24, CHANGE OF USE PORTION OF WAREHOUSE TO TWO POULTRY MARKETS. SCOPE OF WORK INCLUDES NEW ELECTRICAL EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2345. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42422	18041-10000-41153	13627 W SUNSET BLVD	90272	11	129B133    62	4425013016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.0526	-118.50356	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 45 MODULES USING POWER OPTIMIZERS(P320)EXISTING PV SYSTEM ON ROOF. (INFORMATION UNKNOWN)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42423	16041-20000-40686	6040 N CALVIN AVE	91356	3	177B117   584	2153035013	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.1803	-118.55544	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 400A split bus panel.20.16kW ungrounded system. (56) 360W ac modules. NOTE: Fees are $0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42424	14041-10002-34455	1011 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197    80	5037026017	P-1, [Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM			PC Approved	12/17/2014 12:00:00 AM	ADDRESS	34.01107	-118.29253	Plan check only for 2013 building energy efficiency standards.  (((RENOVATION/ADDITIONAL FOR ELECTRICAL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42425	14041-20000-07928	6203 N RADFORD AVE	91606	2	177B169   351	2334009059	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.18324	-118.39228	Roof mounted PV system with tranformerless.  System size 4.5KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42426	19041-20000-40376	18448 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42427	15041-10000-05312	380 WORLD WAY T81A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for interal signages inside the airport	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42428	18041-10000-33316	8550 N BALBOA BLVD STE 190	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.22649	-118.5024	REPLACE INDOOR FLUORESENT TROFFERS WITH NEW LED RETROFIT KITS  T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42429	12041-20000-22025	4432 N AZALIA DR	91356	3	165B121   123	2177017003	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.15153	-118.53982	"New rooftop photovoltaic system for an existing single family residence.  Plan check is for PV system only.  Permit fees, including 200A service upgrade are under ""Inspection""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42430	14041-10000-35655	5900 W WILSHIRE BLVD 3rd floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for Title 24 only. Project site is the 3rd floor of a high-rise building. Total lighting area = 2,035 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42431	19041-10000-45047	900 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.04526	-118.26611	Energy plan check only, area of scope (892)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42432	17041-10000-03131	2049 S CENTURY PARK EAST 7TH FLOOR-LOBBY	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Issued	02/02/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY. INTERIOR RENOVATION OF ELEVATOR LOBBY ON THE 7TH FLOOR. TOTAL AREA 375 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42433	14041-20000-10154	5956 N RESEDA BLVD	91356	3	177B125   733	2157001155	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	PIN	34.17906478	-118.53535882	NEW RETAIL. new meter spot. low connected load. 100 sq ft kiosk. pc for t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42434	17041-10000-39815	9500 S BROADWAY Bldg #1	90003	8	093A203    88	6053006053	C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.94989	-118.27798	Remove outdoor HID Fixtures and replace it with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42435	14041-10000-26441	16425 W HART ST	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.19764	-118.49103	Title 24 plan check only.  Total area = 11784 sq. ft.  Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42436	19041-20000-36958	23322 W GONZALES DR	91367	3	171B093   585	2044024029	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Issued	09/16/2019 12:00:00 AM	ADDRESS	34.16353	-118.63492	PV1. INSTALL 7.695 KW DC / 6.54 KW AC ROOF MOUNTED SOLAR SYSTEM WITH (27) MODULES AND OPTIMIZERS AND (1) INVERTER (SE6000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42437	14041-20001-24184	19543 W SAN JOSE ST	91326	12	207B117   435	2708005020	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM			PC Approved	09/17/2014 12:00:00 AM	ADDRESS	34.26073	-118.55921	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.2KW INTERCONNECTED WITH MSP.(50) KYOCERA KD255 MODULES(50) POWER OPTIMIZERS P300(2) SOLAR EDGE SE6000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42438	19041-10001-40996	737 S LAMAR ST	90031	14	135A219   168	5410013011	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.06375	-118.22383	Expedite fees for Solar	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42439	18041-10000-03910	888 S FIGUEROA ST 475	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.0465	-118.26225	PC FOR ENERGY ONLY FOR AN OFFICE TI FOR ON 4TH FLOOR IN A HIGH RISETOTAL AFFECTED AREA 1989 SQ.FTSCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS. B#17016-10000-35511	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42440	14041-10003-17346	9317 W PICO BLVD bldg C	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.05542	-118.3934	Delta 10 changes-reduced installed lighting wattage and modifyinverter circuits((((((Plan check for power and lighting.  Total area = 16,270 sq. ft.Remodel and building addition. Existing services are being replaced.  3 buildings in complex; one is not touched, one is remodeled, one is demolished and rebuilt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42441	19041-10000-25603	8545 N HATILLO AVE	91306	3	192B113    95	2782016011	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.22574	-118.56523	0$ final fees per AB1414PC FOR PV-1 , 49 MODULES WITH MICROINVERTERS, 1 GENERTOR 22KW, TRANSFER SWITCH. SYSTEM SIZE IS 16.660KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42442	18041-20000-41096	11247 W TUXFORD ST	91352	6	195B173   255	2408036040	M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	08/18/2020 12:00:00 AM		Issued	08/18/2020 12:00:00 AM	ADDRESS	34.23086	-118.37673	2000A 480Y/277V service upgrade to (E) industrial light manufacturing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42443	14041-20000-28269	685 S NEW HAMPSHIRE AVE 1-177	90005	10	132B197   143	5094008041	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			10/14/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.06041	-118.29315	NEW FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42444	17041-10000-24743	2601 S FIGUEROA ST BLDG 3	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.02804	-118.2763	PC FOR FA SYSTEM SYSTEM. BUILDING 3. TOTAL OF 744 DEVICES AND 18 PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42445	17041-20000-04452	18000 W DEVONSHIRE ST W1035	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.25698	-118.52508	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR WATER STORAGE AND LABRATORY. NON HAZARDOUS PER APPLICANT. ROOM W1035.   2315 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42446	16041-10001-18886	4141 N ELMER AVE	91602	2	162B173   134	2366030013	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.03	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.1435	-118.37692	08/11/16Changes to an approved set of plans. All changes are clouded. Changes include replacing the type of module from LG Solar LG315N1C-G4 to LG Solar LG320N1C-G4, relocating 6 modules on the roof-layout to the roof of a detached garage, and revisions to single line diagram. Note: permit is paid under PCIS#16041-10000-18886((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(14)MODULES-LG LG315N1C-G4(14)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE3800A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42447	13041-10000-05290	20033 W PARTHENIA ST	91324	12	195B113   462	2782012048	(T)RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.22836	-118.56974	PV1 PLAN CHECK ROOF MOUNTED PHOTOVOLTAIC SYSTEM INSTALLATION IN A TWO STORY DWELLING. SYSTEM SIZE IS 14.25 KW DC USING  57 MODULES IN 6 STRINGS, TWO COMBINER BOXES AND TWO TRANSFORMERLESS INVERTERS. PERMIT INCLUDES MAIN SERVICE PANEL UPGRADE TO 225A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42448	18041-10000-10749	22121 W CLARENDON ST	91367	3	174B101   399	2169026110	(T)(Q)RAS4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.16978	-118.60882	NEW GROUND-CANOPY MOUNTED SOLAR SYSTEM ON AN EXISTING PARKING STRUCTURE. CONSIST OF 250 MODULES (TRINA SOLAR-TSM-325PE14A) AND A CENTRAL INVERTER (SOLECTRIA SOLAR- PVE 60 TL 60Kw). SYSTEM SIZE IS 60KWac AND 81.25KWdc. PERMIT FEE IS  ZERO DOLLARS IN ACCORDANCE WITH CA SB-1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42449	19041-10000-35111	881 N VIA DE LA PAZ	90272	11	129B125   603	4412004015	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.04701	-118.52732	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42450	19041-20000-33386	3325 W EXPOSITION PL	90018	10	120B185  1405	5044002012	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.02155	-118.33249	Plan check for Title 24 Energy only for Tenant Improvement Office space 1st and 2nd Floor. Total area: 10,148 sq ft Note: one plan for two application number(19041-20000-33386 and 19041-20000-33390)B#19016-10000-21282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42451	16041-20000-17271	18824 W KENYA ST	91326	12	210B121   590	2717022028	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.2697	-118.54412	PV1.  Install 10.46 kW roof-mounted PV system.  (32) 327W modules with (2) 5kW rated central transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42452	19041-10000-41851	5640 W SANTA MONICA BLVD	90038	13	144B193   770	5536018022	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Info Complete	02/13/2020 12:00:00 AM	ADDRESS	34.09063	-118.31282	T-24 PLAN CHECK FOR A T.I. OF EXISTING HOTEL LEASING OFFICE AND RESTROOM. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 718 SQ.FTB#19016-10000-32943	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42453	16041-20001-44654	7179 W FOOTHILL BLVD	91042	7	202-5A199 450	2568014007	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM			PC Info Complete	11/03/2017 12:00:00 AM	ADDRESS	34.24867	-118.28837	TI and addition to existing night club/banquet hall.  New 600 A 240/120V 3ph-4w service.  Assembly occupancy - A3 with 452 occupants. Partial permit fees paid under 16041-20000-44654.  (((Plan check for energy only. TI and addition to existing night club/banquet hall. New lighting (incl. emergency). 6,100sqft.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42454	18041-10000-42237	11135 W WEDDINGTON ST	91601	2	171B173  1413	2350015115	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			PC Info Complete	11/02/2018 12:00:00 AM	ADDRESS	34.1671	-118.37381	Energy plan check for an office T.I. Scope includes new lighting and equipment with a total area of 6365-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42455	18041-20001-38726	5101 N CALATRANA DR	91364	3	171B105  1127	2168015049	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.16127	-118.60255	Expedite per applicant requestPlan check for PV roof mounted system, system size: 11.5KW DC, 9.24KW AC with 35 PV modules 1 inverter(11.4kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42456	16041-20000-33010	6222 W FOUNTAIN AVE 1-73	90028	13	144B189   112	5534001024	R3-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Apartment			09/16/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.09425	-118.32555	NEW FACP.  UPGRADING EXISTING FIREALAM SYSTEM WITH NEW FIRE ALARM PANEL AND 58 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42457	13041-10000-29379	1109 S GLENDON AVE	90024	5	132B153   180	4363022003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.06052	-118.44439	T.I. for new restaurant in an (E) 2-story building.  No change of use.  Proposed occupant load in excess of 200 occupants, likely A2 occupancy.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42458	18041-10002-41854	341 N VAN NESS AVE	90004	4	138B189   219	5522027018	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.07738	-118.31586	Revision to PV system, scope include relocating inverter,pv system meter, ac disconnect and utility meter. change in sheet 2 only ,  marked delta A . original PC # 18041-10000-41854.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42459	16041-10000-05341	2049 S CENTURY PARK EAST 12TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON SUITE 1200 (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5890 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42460	19041-10000-45943	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	09/08/2020 12:00:00 AM		Permit Finaled	11/10/2021 12:00:00 AM	ADDRESS	34.05715	-118.41482	FULL PC FOR POWER AND ENERGY, FOR A TI, SCOPE OF WORK INCLUDES THREE NEW PANELS, AND THREE NEW TRANSFORMERS CONNECTED TO AN EXISTING ELECTRICAL SYSTEM. SUBMITTED PER APPLICANTS REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42461	12041-10000-19471	3115 S PURDUE AVE	90066	11	120B153   812	4250021022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.0241	-118.43241	NEW 7.4KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42462	13041-20000-14677	13276 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24. 15 PANELS IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42463	14041-20000-19768	18000 W DEVONSHIRE ST	91330	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.25313	-118.52557	PC FOR TITLE 24 ONLY.  COMMERCIAL BUILDING ONE FLOOR IN CONFERENCE ROOM.  LIGHTING CIRCUITS EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42464	17041-20000-24516	15910 W VENTURA BLVD ste 1100	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.15561	-118.47969	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42465	10041-20000-20688	5233 N OAK PARK AVE	91316	5	171B133   232	2258025026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.16634	-118.50452	Plan check 12.6KW Photovoltaic system for single family dwelling and misc. permit for replace existing main breaker from 200A to 175A main.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42466	15041-10000-01390	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.04661	-118.2324	Plan check for power. Project is the addition of power equipment to an existing distribution board. The scope of the work covers a single unit (Unit Q) in a mixed use building. Work for other units is currently being plan checked under application: 14041-10000-35160.Per supervisor instruction, 2 additional plan check hours have been added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42467	18041-10000-24026	10653 N LAUREL CANYON BLVD	91331	7	207B153   576	2618006016	R2-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.26359	-118.43758	PV 1. NEW 9.975 KWdc / 8.05KWac ROOF MOUNTED PV SYSTEM WITH 35 MODULES AND MICRO INVERTERS.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42468	18041-10000-06931	13346 W BEAVER ST	91342	7	225B157   197	2510012029	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.31629	-118.42339	Plan check for  PV roof mounted system. Total system size: 6.0kWac (1) 6.0 kW inverter and 28 modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42469	19041-20000-21094	7665 N MARLBOROUGH CT	91304	12	186B093    48	2027029035	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.2098	-118.64115	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6.615KW DC/6KW AC/4.805 KW AC CEC.. SCOPE OF WORK INCLUDES (21) HANWHA PV MODULES WITH P320 POWER OPTIMIZERS, AND A SE6000H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42470	10041-10000-13160	2650 E OLYMPIC BLVD	90023	14	120A219    13	5169010006	C2-1, M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	10/15/2010 12:00:00 AM		Permit Closed	01/26/2012 12:00:00 AM	ADDRESS	34.02485	-118.22188	REPLACE AN EXISTING DAMAGED 3,000 AMP SERVICE.  PLAN CHECK IS FOR POWER ONLY.  THE BUILDING IS NOT OCCUPIED AT THIS TIME. ALL FUTURE TENANTS ARE REQUIRED TO OBTAIN ELECTRICAL PLAN CHECK APPROVAL PRIOR TO OCCUPANCY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42471	14041-10001-02447	711 N NEW HIGH ST	90012	1	133-5A215 110	5408022003	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	ADDRESS	34.0605	-118.23856	Title 24 plan check only for energy efficiency of changes to lighting system per inspector request.  (((REMODEL FOR FISH MARKET.  INSTALL NEW CIRCUITS FOR OUTLETS AND EQUIPMENT.  REPLACE (5) LIGHTS UNDER EXISTING CIRCUITS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42472	18041-10002-42490	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Approved	08/05/2019 12:00:00 AM	ADDRESS	34.02201	-118.28947	"DETA ""1"" CHANGES TO THE APPROVED PLANS FOR CHANGING THE LOCTION OF BATTERY STORAGE SYSTEM IN THE BASEMENT AND INCREASING THE TRIP SETTING TO 2,000 AMP FROM 1,600 AMP WITH NEW FEEDERS.<<<PC FOR ADDITION OF UPS AND POWER CONDITIONER TO BASEMENT OF USC BUILDING. CONNECTING TO EXISTING 3000A SERVICE AND A 4000A GENERATOR TO PROVIDE EMERGENCY POWER. SCOPE INCLUDES ADDING A 1000KVA UPS TO EXISTING DISTRIBUTION SYSTEM WITH ASSOCIATED EQUIPMENT - SEE SHEET E-600 FOR SINGLE LINE CHANGES - COPY OF EXISTING APPORVED SET OF PLANS HAVE BEEN ATTACHED>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42473	15041-10000-37645	4853 N LANKERSHIM BLVD	91601	2	168B173   297	2353020006	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.15899	-118.3713	Constructing a new 867 SF drive-thru and walk-up starbucks bldg., new exterior uncovered 19 seats outdoor seating with railing, new canopy, new rooftop, ac units, new clearance bar at drive-thru and new pole lights.PLAN CHK IS FOR TITLE 24-INDOOR AND OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42474	12041-20000-25282	521 E VENEZIA AVE	90291	11	108B145  1757	4237003011	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM			PC Approved	10/22/2012 12:00:00 AM	ADDRESS	33.9891	-118.45995	Plan check for energy and emergency lighting. Manufacturing warehouse. 2944 inddor and 1008 sqft outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42475	10041-20000-10250	12000 W RIVERSIDE DR 1-96	91607	2	168B165   610	2355014024	(Q)R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Apartment			06/01/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.15739	-118.39452	96 units apartment new design new owner variance for fire alarm filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42476	19041-20000-15364	555 S FLOWER ST 37TH FLR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	T24 PLAN CHECK ONLY FOR TI REMODEL OF EXISTING HIGH RISE COMMERCIAL BUILDING 37TH FLOOR. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 22,075 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42477	14041-20000-18815	17617 W RUNNYMEDE ST	91406	6	186B129   593	2202020014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.20624	-118.51701	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42478	14041-20000-03005	8734 S BELLANCA AVE	90045	11	096B169   844	4125018007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	33.95765	-118.38038	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON BOTH THE FIRST AND SECOND FLOOR. LIGHTING USING EXISTING CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42479	12041-10000-27673	4031 N KARELIA ST	90065	14	150A219   181	5464006070	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.10526	-118.22208	tHIS IS A ONE SRORY , MICRO INV. PV SYSTEM, FOR A SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42480	14041-20001-02621	10923 W RANDALL ST	91352	6	198B173    51	2408001022	(Q)M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.23908	-118.36897	Changes from the previously approved plans.  Changes include new 400A service panel.  Plan check for power only.*****pc for new 800A service upgrade. new pull section and distribution board. all loads existing. no new loads at this time.****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42481	13041-10001-36089	128 N ELLITA PL	90042	1	150A227    23	5468017008	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/24/2014 12:00:00 AM	ADDRESS	34.10733	-118.19953	Expedited RSES plan check per applicant request. {{PV1, Install 1.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Power-One AuroraPVI-3.0-outd-s-us. (6) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42482	14041-10000-32156	1435 W 7TH ST	90732	15	015B193   409	7459001016	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	33.7377	-118.30896	Energy plan check for an assembly and school area. Indoor and outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42483	13041-10000-30065			11	111B141   209	4240003002	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	PIN	33.99946408	-118.47201642	INTERIOR & EXTERIOR T.I.  TO (E) RETAIL BUILDING :  REMOVE DEMISING WALLS BETWEEN TWO TENANT SPACE & MAKE  ONE TENANT SPACE for officesPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42484	19041-10000-14706	333 N CROWN DR	90049	11	135B141   600	4403014005	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.06477	-118.48023	PLANCHECK  PWR FOR TWO STORY SFD. NEW SERVICE 800A, 120/240V, IPH, 3WIRE. SCOPE INCLUDE 1 SWITCH BOARD AND 1 NEW PANEL ALONG EXISTING PANELS AND GENERATOR DELTA 2 CHANGES ONLY. ORIGINAL PLANS ARE INCLUDED.PERMIT UNDER BLDG  # 15010-30K-02125	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42485	15041-10001-21658	855 W 126TH ST	90044	15	081B197   237	6117017018	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	33.91796	-118.29075	EXPEDITED FEES FOR ROOF MOUNTED SOLAR SYSTEM. (((PV1, ROOF MOUNTED SYSTEM. (28) MODULES (1) INVERTER. TOTAL SIZE 7.28 KW(28) KYOCERA #KU2606XPA (1 ) PV1-6000-OUTD-US-Z-A)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42486	13041-10000-10169	6433 N FIGUEROA ST	90042	14	154-5A231  71	5493005010	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01, 1832.20	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.11885	-118.18382	TI OF EXISTING RETAIL SPACE. NO CHANGE OF USE. NBEW LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 4160 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42487	13041-10000-29165	236 E 58TH ST	90011	9	108B205  1113	5101021001	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	33.98966	-118.27053	PLAN CHECK FOR POWER AND ENERGY. TENANTING IMPROVEMENT. 1 STORY COMMERCIAL BUILDING.  NOT A MEDICAL OFFICE ACCORDING TO APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42488	12041-20000-08111	101 S THE GROVE DR	90036	4	138B177  1131	5512003038	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	ADDRESS	34.07256	-118.35874	Plan check for energy and emergency lighting. 410sqft single story conditioned storage area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42489	17041-20000-32645	8415 N SEDAN AVE	91304	12	192B093   118	2005007026	RS-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.22295	-118.63133	Plan check for solar pv system, roof-mounted on SFD.6.44kW ungrounded system.(28) EnPhase IQ6 microinverters.(28) 295W pv modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42490	15041-20000-09635	12682 W SANDHILL LANE 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/01/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.97708	-118.41507	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: SYSTEM SIZE: 1.38KW   LANE # 26 MODULES(1) 3.0 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42491	11041-10000-23837	8436 W 3RD ST	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM			Corrections Issued	11/07/2011 12:00:00 AM	ADDRESS	34.07301	-118.37448	T.I. to an existing office building.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42492	18041-20002-17829	5418 S MCCONNELL AVE	90066	11	102B157    32	4211009018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	33.97832	-118.4197	10/12/2018 Plan check for power only. Work includes the installation of electrical distribution equipment and a transformer. Panel M bus rating is 800 amps and transformer is rated for 300 kVA.*****Previous Work Description*****Plan check for Title 24 energy only T.I. office wearhouse. Total area: 12,798 sq ft.Newly connected load is less than 400A. B#18016-20000-10142	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42493	12041-20000-00498	7348 N BELLAIRE AVE	91605	2	186B161   507	2324002030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			01/09/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.20515	-118.40928	Remodel existing space into banquet hall,  Place of assymbly.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42494	16041-20000-03302	10201 W PICO BLVD Galaxy-Garage	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check for Title 24 only. Project site is an existing parking garage. Project scope is carport lighting. Total lighting area = 39,580 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42495	14041-20000-07157	7905 N VAN NUYS BLVD	91402	6	189B149   451	2210022057	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.21446	-118.44897	T24 FOR EXISTING STORAGE CONVERTING TO OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42496	15041-10002-01901	5959 W FRANKLIN AVE	90068	4	150A191   161	5586014027	R3-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			07/07/2016 12:00:00 AM			No Progress	08/02/2016 12:00:00 AM	PIN	34.1055012	-118.31956142	Plan check only.  Changes to approved set.  Changing feeders from copper to aluminum.  Garbage disposal and dishwasher removed.  Cooktop and small appliance branch circuit added.  Load calculations updated.  (no net changes to permitable items)            ********         PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT TO 49 APARTMENT UNITS. NEW 800 SERVICE, PANEL UPGRADES, NEW CKTS AND NEW HEAT PUMPS FOR EVERY UNIT .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42497	15041-10001-42376	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Closed	12/16/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	PC AND PERMIT FOR SUPPLEMENTAL SET OF PLANS. CLARFICATION OF TOWER CRANE, NOT COMPRESSOR UNITS. MAKING TOTAL OF 2 TOWER CRANES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42498	11041-10001-19089	735 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Expired	10/27/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	(((((((((((((((((      8-22-12    changes made to previously approved set , new equipment and panels , ckts  added, chane in title 24.    ))))))))))TENANT IMPROVEMENTS FOR TARGET STORE. Plan check power, T24 and emergency lighting.  Existing service equipment.  Ref.#11042-10000-15835.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42499	17041-10001-34024	820 S WILTON PL	90005	4	132B189   709	5092026016	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			09/04/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	07/08/2022 12:00:00 AM	ADDRESS	34.0573	-118.3141	"DELTA ""3"" Changes to approved plans in a mixed use Apt Building. Adding loads, changing size of Panels and adding and changing circuits.<<<POWER AND ENERGY ORIGINAL PLAN CHECK SUBMITTAL UNDER 16041-10000-15828 (M.Z PLAN CHECKER ) THIS SUBMITTAL INDICATES CHANGE OF ENGINEER OF RECORD, 2013 NEC AND T-24 FOR NEW CONSTRUCTION 18 UNIT APARTMENT. PERMIT FEES TO BE CALCULATED UNDER INSPECTION.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42500	16041-10001-45090	1301 W 7TH ST	90017	1	130-5A205 108	5143013022	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			06/28/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.05249	-118.26766	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 17. CHANGES FOR NEW SERVICE LAYOUT DUE TO DWP SERVICE CONSTRAINTS. REVISING SINGLE LINE DIAGRAM WITH NEW SERVICE 1600A 120/240V WITH 1500KVA TRANSFORMER. ALSO ADDING ADDITIONAL PANELS,  AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42501	16041-10001-26516	10000 S VERMONT AVE	90044	8	091-5A199 131	6054009029	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM			PC Approved	07/21/2017 12:00:00 AM	ADDRESS	33.94531	-118.29139	ADDITION OF 2 PAGES TO BE PART OF PLANS. GROUNING DETAILS AND TITLE PAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42502	11041-10000-04089	335 N JUANITA AVE 1-49	90004	13	138B197   144	5501001003	R4-1	Central	Wilshire	Rampart Village	YES	1927.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.07732	-118.29078	New Fire Alarm system for an appartment BLDG. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42503	17041-20002-02108	281 N BENTLEY CIR	90049	5	138B149    66	4366004018	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.07702	-118.45744	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (69) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42504	19041-20000-24328	11835 W OLYMPIC BLVD STE 900E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.03301	-118.45119	T24 PLAN CHECK FOR LIGHTS AND OUTLETS ONLY. WORK ON STE 900E 9TH FLOOR OF EXISTING HIGH RISE COMMERCIAL BUILDING. TOTAL SQAURE FOOTAGE = 10,255 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42505	19041-10000-45242	11001 N DARBY AVE	91326	12	210B125   576	2715003041	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.26984	-118.53396	(E-PLAN) NEW PV1 ROOF-MOUNT INSTALLATION TO AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 1 ENERGY STORAGE SYSTEM, 2 PANELS OF 125 AMPS, 1 CENTRAL INVERTER (SE5000H-US), 14 MODULES (VBHN320KA03), AND 14 OPTIMIZERS (P-320).  SYSTEM SIZE: 4.62 KW DC, 5.00 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42506	19041-10000-53528	5831 W SANTA MONICA BLVD	90038	13	144B189   597	5534017021	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			Reviewed by Supervisor	01/08/2020 12:00:00 AM	ADDRESS	34.09089	-118.31683	FULL PC FOR CORE AND SHELL, SCOPE OF WORK INCLUDES A NEW 4000A SERVICE (480/277 3P,4W) THAT FEEDS VARIOUS NEW TRANSFORMERS AND ASSOCIATED DISTRIBUTION EQUIPMENT, TOTAL AFFCTED AREA IS 56,467 SQFT. PER BUILDING (((CORE & SHELL ADAPTIVE REUSE RENOVATION. SCOPE OF WORK INCLUDES CIVIL, STRUCTURAL & (N) TRELLIS DECK ADDITION.19014-10000-06984)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42507	15041-20000-26165	4416 N BELLINGHAM AVE	91604	2	165B165   319	2364002031	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Expired	09/06/2017 12:00:00 AM	ADDRESS	34.15095	-118.39855	Installation of new roof mounted solar PV array.  Total system size = 8 kWac.  Two inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42508	17041-10000-21509	2201 E WASHINGTON BLVD	90021	14	118-5A215   6	5167019900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.01911	-118.23383	Pc for T24 only for new lights in mezanine area and corridor.  Total affected area is 1252 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42509	14041-20001-30646	12160 N DELANTE WAY	91344	12	219B125    77	2601074002	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM			PC Approved	04/16/2015 12:00:00 AM	ADDRESS	34.29475	-118.52792	PV SYSTEM IS INSTALLING 12 MODULES. TOTAL INSTALLED PER THIS PERMIT IS 3.48KW DC. THE ADDITION OF MODULES IN FUTURE WILL REQUIRE SEPARET PERMIT. PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.5kw dc / 8kw AC8kw ac inverter installed. only 3.5kw dc panels installed at this time	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42510	18041-10000-15481	7437 N RESEDA BLVD	91335	3	186B125   562	2118014017	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.20578	-118.53625	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42511	15041-10001-18890	12725 N DE FOE AVE	91342	7	219B149    28	2508021039	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2015 12:00:00 AM			Verifications in Progress	07/22/2015 12:00:00 AM	ADDRESS	34.30106	-118.44661	EXPEDITED TO SOLAR ROOF MOUNTED SYSTEM.PV1, ROOF MOUNTED SOLAR SYSTEM. TOTAL SIZE, 7.85 KW. (24) MODULES SUNPOWER 327(2) INVERTERS: SMA AMERICA SB3800TL-USSMA AMERICA SB3800TL-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42512	17041-30000-34431	518 N GRAMERCY PL 1-51	90004	4	141B193  1072	5522013015	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.08086	-118.3124	Plan check for new Fire alarm system for 4 story 51 units. Total fire alam devices: 147 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42513	15041-20000-03541	4136 1/2 W ROSEWOOD AVE UNIT 1	90004	13	141B197  1122	5520017018	R4-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.0789	-118.29459	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(11) SOLARWORLD SUNMODULES 265(1) SOLAREDGE SE3800 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42514	17041-10000-40657	6514 N SYLMAR AVE	91401	2	180B149   547	2237015900	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.18923	-118.4464	Plan check for T24 only, lighting retrofit / Lighting rehabilitaition project on an (E) Senior Citizen Center. Total area under the SOW:  17,000sq.ft indoor + 29,000 sq.ft. All new lights connect to the existing lighting branch circuit in the area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42515	13041-20001-34014	4411 N LAUREL CANYON BLVD	91604	2	165B165   368	2364002022	[Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM			PC Approved	05/27/2014 12:00:00 AM	PIN	34.15064369	-118.39684616	Re-plan check for title 24 due to loss of approved plans.  (((T24 EXISTING RETAIL. 2297 SQRFT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42516	11041-10000-12413	360 N BELMONT AVE	90026	13	136-5A207 163	5159022001	C2-1	Central	Westlake	Greater Echo Park Elysian		2083.02	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.06834	-118.26291	TI TO AN EXISTING OFFICE SPACE ON THE SECOND FLOOR, UNIT 360.  PLAN CHECK FOR ENERGY>  PERMIT IS FOR 10 NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42517	13041-10000-11773	6725 N MCLENNAN AVE	91406	6	180B133    72	2231022072	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.19274	-118.50015	PV1 SINGLE STORY HOUSE.  INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL.  SYSTEM SIZE: 7.35 KW DC.  3 STRINGS OF 10 MODULES EACH.  {30 MODULES: TSM 245-PA05} {CENTRAL INVERTER: FRONIUS IG PLUS 10.0}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42518	17041-20000-00778	941 W 35TH ST	90089	9	120A201    44	5039012030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Closed	09/24/2018 12:00:00 AM	PIN	34.02328797	-118.28705198	Plan check for power only. Project site is the North Complex Residence Halls at USC. Project scope is a electrical infrastructure upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42519	18041-10000-28132	1030 N SWARTHMORE AVE #3-107	90272	11	129B125   834	4423016008	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	"***SEE APPLICATION COMMENTS***PC FOR FIRST TIME TENANT ""CUYANA""  TENANT IMPROVEMENT TO RETAIL SPACE IN NEW MALL- PALISADES VILLAGE. FOR POWER AND ENERGY. SCOPE INCLUDES NEW PANEL, CIRCUITS, EQUIPMNET AND LIGHTS. TOTAL AFFECTED AREA 1139 SQ. FT VANILLA SHELL UNDER 18041-10000-15106  PERMIT WAS NOT PULLED FOR VANILLAb#18016-10000-12671"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42520	19041-10000-24026	17111 W TRIBUNE ST	91344	12	207B133   124	2696021004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM			PC Approved	06/21/2019 12:00:00 AM	ADDRESS	34.26694	-118.5057	(Plan check only) PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 29 MODULES (Q-CELL 305), OPTIMIZERS (SUN2000-375W-USP0) AND A CENTRAL INVERTER (SUN2000-7.6KTL-USL0). SYSTEM SIZE IS 8.845KWdc AND 7.6KWac. PERMIT FEES ARE PAID UNDER EXPRESS PERMIT # 19041-9000-09418NO SERVICE PANEL UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42521	19041-10000-07080	5916 N MONTEREY ROAD	90042	14	150A231   180	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Hermon		1837.02	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.10506	-118.1842	T-24 ONLY FOR A TI OF A RESTAURANT. (NO CHANGE OF USE). SCOPE INCLUDES NEW CIRCUITS, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 972 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42522	15041-10000-24662	20301 W STRELNA PL	91364	3	168B113   137	2174003042	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Expired	08/25/2017 12:00:00 AM	ADDRESS	34.15879	-118.57527	PV1, ROOF MOUNTED SYSTEM. (23) MODULES AND 1- 6KW INVERTER. TOTAL SIZE IS 6.21KW. (23) HYUNDAI HIS-S270RG(BK)(1) ABB PV1-6000-OUTD-US-AReference Building permit #: 15016-10000-16105	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42523	15041-10000-38433	4247 N EAGLE ROCK BLVD	90041	14	156A219    67	5473024020	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	PIN	34.12292955	-118.22381583	Full PC for  a new 59 unit apartment plus retail at basement. (4 Story building). New 2000 A service. Total Sqft = 51737. Fees per customer estimate.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42524	12041-10000-29710	23355 3/4 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.1579	-118.63422	PLAN CHECK FOR TITLE 24 (1453 SQ FT)  LOW RISE. EL CAMINO SHOPPING CENTER STARBUCKS TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42525	16041-20000-19771	6405 N HESPERIA AVE	91335	3	180B125   623	2123015006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.18743	-118.52571	PV1.  Install 5 kW roof-mounted PV system.  Central inverter standard plan.  (20) modules with (1) 5kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42526	12041-10001-10371	4160 W WILSHIRE BLVD #201	90010	4	132B189    60	5092001046	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.06152	-118.31825	Modification to previously approved set of plans.  Office use changed from Medical Office to regular office with no examinations.  PLAN CHECK ONLY.                        <<<<<<<<<<TENANT IMPROVEMENT OF AN EXISTING OFFICE INTO A MEDICAL OFFIC WHERE OUTPATIENT SURGERY IS PERFORMED. IN SUITE 201COMPLETE PLAN CHK.  Office is not state licensed and will not be in the future.  Not checked for OSHPD.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42527	16041-20000-40916	5077 N LANKERSHIM BLVD d	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.1626	-118.37361	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighting.  total square footage 1411.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42528	18041-10000-15399	11938 W COHASSET ST	91605	2	186B165   401	2317013018	R1-1, RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			Corrections Issued	04/26/2018 12:00:00 AM	ADDRESS	34.20654	-118.39349	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 7.6KW(SE7600H-US), CONSISTING OF 25 MODULES WITH POWER OPTIMIZERS(P320)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42529	13041-20000-34644	5608 N VAN NUYS BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.1725	-118.44837	THIS PLAN CHECK ONLY COVERS NEW 200A PANEL AND FEEDER FROM EXISTING METER FOR A FIRST TIME TENANT. PERMIT IS ON APPLICATION#: 13041-90000-32348 **FULL PLAN REVIEW IS REQUIRED FOR THE CONTRACTOR INSTALLING THE LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42530	17041-20001-41873	11894 N WHEELER AVE	91342	7	216B165    49	2531033021	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.28659	-118.39843	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array for SFD. Center-fed panel.3.8kW ungrounded system. (14) 285W pv modules. (14) 320W power opimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42531	16041-20000-13689	350 S HILL ST	90013	14	130-5A211 149	5149015024	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			PC Info Complete	06/13/2016 12:00:00 AM	ADDRESS	34.05047	-118.24998	INSTALLATION OF A NEW FIREALARM SYSTEM FOR BRAND NEW MIXED USE HIGH RISE BUILDING.  36 PANELS AND 2584 DEVICES AND 733 SMOKE DETECTORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42532	13041-10000-35185	8631 W 3RD ST # 410	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.07373	-118.38036	PLANCHECK FOR T24 ENERGY ONLY PER INSPECTORS REQUEST.  NOT A PATIENT CARE AREA  ACCORDING TO APPLICANT. ONLY OFFICES. TENANT IMPROVEMENT FOR SUITE 410. 1469 SQ FT, EMERGENCY LIGHTING. PERMIT HAS BEEN PREVIOUSLY PULLED UNDER 13041-90000-31115, 13041-10001-31115.(BUILDING PERMIT # 13016-10000-11130.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42533	13041-10000-24636	16906 W MARLIN PL	91406	6	183B133   629	2230006014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM			PC Approved	09/09/2013 12:00:00 AM	ADDRESS	34.197	-118.50164	MODIFICATION TO APPROVED SET OF PLANS. MODULE CHANGED TO ET-P660255WB (255W). SYSTEM SIZE IS NOW 5.1 KW DC AND 4.32 KW AC.  FIRE DEPARTMENT APPROVAL ON 13041-10000-20793. LAYOUT AND MOUNTING METHODS DID NOT CHANGE. ***************************************************************PLAN CHECK FOR PV1 ROOF MOUNTED INSTALLATION ON A MICROINVERTER STANDARD PLAN. SYSTEM SIZE IS 4.32 KW AC AND 5 KW DC. [INVETER: ENPHASE # M215-60-2LL-S22 |||| MODULE: REC # REC 250 PE]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42534	13041-20000-29632	6420 W WILSHIRE BLVD SUITE 900	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	34.06365	-118.36922	T24 EXISTING HIGHRISE OFFICE. SCOPE OF WORK IN SUITE 900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42535	14041-10000-32433	7070 W SUNSET BLVD	90028	4	147B181   701	5548017038	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.0978	-118.34374	Plan check for fire alarm system. System consists of 1 FACP, 1 anunciator, 1 horn strobe, 1 manual pull station, and 1 smoke detector. Project site is commercial (existing restaurant).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42536	16041-20000-15785	11801 SHELDON ST	91352	6	201B169   102	2537021903	[Q]PF-1XL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1218.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Expired	07/20/2018 12:00:00 AM	PIN	34.24538559	-118.39171142	PV2INSTALL GROUND MOUNTED (CARPORT) PV SYSTEM SIZED 82.2KW INTERCONNECTED TO UTILITY (UBS).(322) MODULES(3) ABB INVERTERS 27.6KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42537	10041-20000-07400	22030 W SHERMAN WAY #318	91303	3	183B101   119	2024001023	C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/26/2010 12:00:00 AM		Permit Finaled	07/08/2010 12:00:00 AM	ADDRESS	34.20085	-118.60681	MEDICAL OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42538	18041-20000-34805	5670 W WILSHIRE BLVD STE. 1500	90036	4	135B181   931	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for Title 24 Energy only in existing high-rise office space T.I. Total area: 13207 sqs ft. B#18016-10000-25332	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42539	16041-10000-13187	925 N LA BREA AVE	90046	5	144B181   708	5531016020	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Closed	09/28/2016 12:00:00 AM	ADDRESS	34.08803	-118.34436	(N) ILLUMINATED WALL SIGN READS AS: 925. Total area: 16.1 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42540	11041-10000-21379	5400 N VAN NUYS BLVD	91401	2	172-5A151  16	2248014035	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1285.00	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.16857	-118.44838	FIRE ALARM/SPRINKLER MONITORING SYSTEM, W/ ELEVATOR RECALL AND DUCT DETECTORS FOR A NEW BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42541	18041-20000-22086	3501 S CENTRAL AVE	90011	9	115-5A209 121	5114014006	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	09/08/2021 12:00:00 AM	ADDRESS	34.01152	-118.25676	Plan check for power and energy. Project site is a new 4-story, 74-unit apartment building with 1 level of subterranean parking garage and partial ground floor commercial retail. Work includes a 2,500-amp service and a total lighting area of 55,181 sq. ft.Note: Building application has been generated under 18010-10000-01951	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42542	11041-20000-05216	4950 W SUNSET BLVD 2ND FLOOR	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.09786	-118.29745	NURSE STATION B AND C KAISER MEDICAL OFFICE 2ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42543	19041-10000-48215	14367 W HERRON ST	91342	7	219B149   420	2507021012	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.29746	-118.44656	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 3.78KWdc (3.8KWac) USING 12 QP315 MODULES & DELTA SOLIVIA 3.8 TL CENTRAL INVERTER. ESS TESLA POWERWALL.CONNECTED TO A 200 AMP EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42544	17041-20002-13254	15157 W ROSCOE BLVD	91402	6	192B145   371	2654024013	(Q)RAS4-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.22161	-118.46296	8.28.2017 - Plan Check for changes to approved set. Rearrange equipment in electrical room. Change interconnecion subpanel from 400A to 225A. Subpanel is now fed from a 125A breaker in main service panel instead of 200A. Existing subpanel bus and feeders changed from 200A to 125A. ==========Plan check for installation of solar pv system, roof-mounted array on commercial building.Interconnect with a 400A subpanel. 23.4kW ungrounded system [9+14.4]. (82) 300W pv modules.Each module has a 300W power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42545	13041-10000-03076	1643 N LINDACREST DR	90210	5	147B165   129	4352006021	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.10086	-118.40508	PV1 for single story home. Total system size: 15.75 KW. [Microinverter used: ENPHASE ENERGY Model#: M215-60-2LL-S22] [Solar Module used: TRINA SOLAR Model#: TSM-250PA05.08].	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42546	15041-10000-23120	8590 W PICO BLVD	90035	5	129B173    75	4303035074	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			07/21/2015 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.05344	-118.37821	"NEW METHANE GAS CONTROL SYSTEM. CONTROL PANEL 10 DEVICES, AND 1 PANEL TO A  7 STORY APARTMENT BUILDING. ***NEEDS TO BE SUBMITTED TO FIRE DEPT. ELECTRICAL SCOPE BEGINS ON ""GC-8.0"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42547	11041-10005-16708	151 N WESTERN AVE	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.07445	-118.30931	NEW 800A SERVICE AND CIRCUITS FOR A GROUP OF 6 COMMERCIAL BUILDINGS.  MAIN SERVICE IS IN BUILDING 4558 W. COUNCIL ST.  OTHER BUILDINGS (4556 W. COUNCIL AVE.,     143 N. WESTERN AVE,      147 N. WESTERN AVE,    149 N. WESTERN AVE.) WILL BE ON SUPPLEMENTAL PERMITS TO THIS.     THIS APPLICATION IS FOR 151 N. WESTERN AVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42548	16041-10001-43684	2708 E MARENGO ST	90033	14	132A227   312	5177004033	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.05446	-118.19728	02/14/2017 Changes to an approved set of plan. Changes include  removed 10 modules from the back house. Changes has been clouded.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42549	19041-10000-02280	1925 S CENTURY PARK EAST SUITE 1300	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLAN CHECK FOR A TITLE 24 ONLY FOR INTERIOR OFFICE TI OF 1,885-SF ON 13TH FLOOR SUITE 1300. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42550	16041-20000-07199	1950 S SAWTELLE BLVD SUITE 200	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.04129	-118.44377	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EDITING AND OFFICES. 9778 SQFT.  SUITE 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42551	18041-20000-35525	4955 N VAN NUYS BLVD ste 111	91403	4	169-5A151  13	2263026046	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.16078	-118.4489	addition of a supplemental generator to an exisitng commercial building reconnecting to exasting panels.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42552	14041-20000-18727	11911 W RIALTO ST PV 1	91352	6	192B169   134	2633013022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.21	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.22601	-118.39222	PV1.  Install 4.578 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.  Permit previously obtained under 13041-20000-23551.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42553	15041-10000-03690	619 N BRITTANIA ST 1-3	90033	14	130-5A223 309	5175032022	R3-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			02/06/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.05116	-118.21231	"Installation of roof mounted solar PV array.  Total system size = 3.6 kWac""The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96 or approved plans by the LAFD"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42554	13041-20000-12757	21255 W BURBANK BLVD Suite 300	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			PC Approved	05/16/2013 12:00:00 AM	ADDRESS	34.17432	-118.59446	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON THE 3RD FLOOR. 10,617SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42555	19041-20001-37372	3733 N DELLVALE PL	91436	5	162B137   452	2293003012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.13856	-118.49488	EXPEDITED PER CUSTOMER REQUEST.PV1. INSTALL 15.360 KW DC ROOFMOUNTED SOLAR SYSTEM WITH (48) MODULES AND OPTIMIZERS, (2) INVERTERS (SE7600H-US) AND (1) LG STORAGE BACK-UP BATTERY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42556	18041-10000-33309	424 S LOS ANGELES ST	90013	14	129A213   285	5148007005	C2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.04664	-118.24676	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42557	14041-10000-29985	2735 S FIGUEROA ST	90007	9	121-5A203 142	5123015016	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.02634	-118.27738	New Starbucks shop within an existing building (existing Del Taco; not first time tenant). Plan check for power and lighting. Indoor lighting area = 3,084 sq. ft. and outdoor lighting area = 2,450 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42558	14041-20000-24900	21111 W OXNARD ST	91367	3	177B105    68	2149005044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.17943	-118.5934	TI TO AN EXISTING COMMERCIAL BUILDING ONE STRORY.  ADDING NEW LIGHTS, CIRCUITS AND PANELS.  PLAN CHECK FOR TITLE 24 ONLY AND EMERGENCY LIGHTING.  6865 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42559	13041-10001-34471	152 S SERRANO AVE	90004	10	138B193  1184	5517012011	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	05/09/2014 12:00:00 AM	ADDRESS	34.0722	-118.30656	Expedited RSES plan check per applicant request.{{PV1, Install a 10.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformered inverter(s)[FRONIUS # IG Plus V 10.0] and (42) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. }}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42560	16041-10001-03828	515 S FLOWER ST FLR 51, 52-& 52M	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM			PC Info Complete	09/27/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	SUPPLEMENTAL CHANGES TO APPROVED SET OF PLANS CLOUDED UNDER DELTA 6. CHANGES INCLUDE RE-ROUTING OF THREE SUBPANELS, NR51-D,NR52-C, NR52-D AND NR51-B. CHANGES ALSO INCLUDE TWO NEW 75KVA AND 45 KVA TRANSFORMERS.**FULL PC FOR AN EXISTING 52-STORY OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS, NEW RECEPTACLES, AND THREE NEW PANELS FOR THE 51,52, AND 52M FLOOR LEVELS. TOTAL AFFECTED AREA IS 36180 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42561	15041-20001-18001	51 E PALOMA AVE	90291	11	109-5A143 172	4286021026	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	33.99432	-118.47785	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total area = 6.25 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42562	18041-20000-49109	2576 S AMHERST AVE pv1	90064	11	120B149   444	4257022040	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.02486	-118.44767	pv1install roof mounted pv system sized 1.1KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42563	16041-20000-43889	20549 W CALIFA ST	91367	3	174B109    74	2151018017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	01/28/2017 12:00:00 AM	ADDRESS	34.17626	-118.58154	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A solar ready MSP. 13.6kW (7.6+6) ungrounded system. (72) 260W pv modules.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42564	14041-10000-27901	932 S HILL ST	90015	14	127-5A209 243	5139003014	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Public Safety Only			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.04216	-118.25766	NEW FIRE WARNING SYSTEM FOR 18-UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42565	15041-10001-21663	6344 N SEPULVEDA BLVD	91411	6	180B145   859	2242010028	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM			Plans on Hold	04/28/2016 12:00:00 AM	ADDRESS	34.18605	-118.46591	4/15/17Full PC for power and energy only.  Changes to an approved set of plans, changes include the connection of the MCC load, vacuum pump and loads. Connected load > 400amps. Total sq. ft. 6115.(((NEW 600 AMP SERVICE FOR EXISTING CARWASH.  RECONNECTING TO EXISTING PANEL A.  PLAN CHECK FOR POWER ONLY.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42566	09041-20001-21007	5555 W MELROSE AVE Balaban ,-#251 bldg.	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/11/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	ADDRESS	34.08363	-118.32191	Supplimental to previously approved plan changing the lighting layout of the office area of the 251.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42567	12041-10000-12982	3418 N HUXLEY ST	90027	4	154-5A205  94	5592001016	R1-1	Central	Hollywood	Greater Griffith Park		1882.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.11626	-118.27361	Plan check for new 9KW roof mounted photovoltaic system. Sinlgle family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42568	11041-10000-03555	8601 S LINCOLN BLVD STE 150	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	33.95939	-118.41943	T.I.  EXISTING SHELL. NEW RESTAURANT LOCATED IN SUITE 150.  2 NEW PANELS AND NEW 200 AMP FEEDER.  SINGLE STORY BUILDING.  FIRE ALARM TO BE DONE UNDER A SEPARATE PERMIT.  FULL PLAN CHECK. <<<<Inspector to verivy the Primary Feeder to the 112.5KVA transformer.  2@ #2AWG in Parallel is not allowed!!!>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42569	13041-10002-10580	380 W WORLD WAY T52	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	[[[[[[[[[[DELTA 3 CHANGES ONLY, CHANGING AND AVAILABLE 400W EMERGENCY INVERTER TO 2 EMERGENCY INVERTERS (1 375W , 1 125W). PERMIT IS EXISTING]]]]]]]per applicant's request, application taken in as a full plan check for power (T24 has already been done). power fees to be added under submittal 2. for concession space #T52-R (Fred Segal)FIRST TIME TENANT OF RETAIL SPACE IN TBIT. PLAN CHECK FOR T24 ENERGY ONLY PER SUPERVISOR REQUEST. TOTAL AREA 2000 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY. WORK DONE IN SPACE T52.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42570	12041-20000-19211	12729 W RIVERSIDE DR	91607	5	168B161   416	2357018006	(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Apartment			08/15/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.15778	-118.41052	Plan check for fire alarm system. 47 Unit apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42571	15041-20003-17696	18711 W SHERMAN WAY	91335	3	183B121   100	2118026019	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.20128	-118.54074	[[[4/6/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 3 CHANGES CLOUDED. CHANGING LIGHTING ON THE ROOF AND PROVIDING EMERGENCY LIGHTING ON THE SAME CIRCUIT THAT FEEDS THE AREA. REMOVING OUTDOOR EMERGENCY LIGHTING ON THE SIDE OF THE BUILDING]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42572	12041-20000-09357	7361 N LAUREL CANYON BLVD	91605	6	186B165   260	2307022010	M2-1VL, P-1VL, R1-1, R2-1	South Valley	North Hollywood	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	07/06/2012 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.20451	-118.39671	Plan  Check per customer request for a new trailer building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42573	17041-30001-20528	11720 W PICO BLVD	90064	11	123B149   742	4260030017	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.03122	-118.44607	Plan check for Title 24 only in existing space T.I. retail space. Total area:  1825 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42574	19041-10000-36288	444 N QUAY AVE	90744	15	030B209   860	7418010047	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	33.77546	-118.25802	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42575	10041-20000-02857	11577 W DILLING ST	91604	2	162B169   101	2368011021	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2010 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.14335	-118.38494	PV SYSTEM FOR SINGLE FAMILY DWELLING OF 6.6KW. balance of fee permit on other permit taking	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42576	11041-10000-20328	6780 N VINELAND AVE	91606	2	180B173    23	2414022025	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.19361	-118.37012	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42577	17041-20000-26016	406 N LAUREL AVE	90048	5	138B177    38	5527033012	R1V3	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.07843	-118.36464	pv1install roof mounted pv system sized 5.7kw interconnected with msp. standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42578	11041-10000-27684	10227 N MASON AVE 1-50	91311	12	204B109   215	2741025038	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Apartment			12/30/2011 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.25626	-118.58016	New Fire alarm system for new apartment building.Note: Electrical Plan under 11041-10000-25644	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42579	16041-10000-14759	13583 W RAYEN ST	91331	6	198B157   520	2625026014	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.23872	-118.42919	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.25KWac.(25)MODULES-SOLARWORLD SW 275 MONO BLACK(25)MICROINVERTERS-ENPHASE M250-602LL-S2X	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42580	17041-20000-08820	15821 W VENTURA BLVD Suite 270	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 21,070 sq. ft.Note: Building permit has been issued under 16016-10000-28617	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42581	15041-20000-08232	1003 N CRESCENT HEIGHTS BLVD	90046	5	144B177   283	5529019017	R4-1	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.08889	-118.36611	PLANCHECK FOR POWER ONLY. 600 AMP SERVICE AND DISTRIBUITION BOARD FOR 5 SFD UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42582	19041-20000-44287	1164 N KENMORE AVE 1-5	90029	13	144B197   439	5540027006	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	06/18/2021 12:00:00 AM	ADDRESS	34.09264	-118.29726	FULL PLAN CHECK FOR A NEW 600A SINGLE PHASE, 120/240V SERVICE. SCOPE OF WORK INCLUDES: 7 NEW PANELS, EQUIPMENT AND LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42583	16041-10000-44938	3559 1/2 W CASITAS AVE LOT 6	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12077	-118.25722	Plan check for Power 11 buildings SFD live work  2 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 6 of 11Note: Master Application Lot 6 type C,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42584	19041-20000-33355	2680 W BANBURY PL	90065	14	157-5A219 171	5473022008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.12636	-118.22395	INSTALL (2) NEW TESLA ENERGY STORAGE BATTERIES ON EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42585	13041-20000-21704	7735 N BETTY CT	91335	12	189B125   996	2102021107	(T)(Q)R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.21136	-118.53298	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.88 KW. 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42586	19041-20000-51831	1947 S MIDVALE AVE	90025	5	129B153  1002	4323005015	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Issued	12/16/2019 12:00:00 AM	ADDRESS	34.04638	-118.43544	Install 19.8 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42587	17041-20001-11171	8055 N RESEDA BLVD	91335	3	189B125   165	2103009039	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM			PC Approved	03/02/2018 12:00:00 AM	ADDRESS	34.21698	-118.53627	03/02/2018 Changes to an approved set of plans. Location of PV equipment has changed. PV system size has remained the same. PV interconnection breaker has changed.*****Previous Work Description*****pv2install roof mounted pv system sized 30kw interconnected with  msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42588	15041-10001-29680	205 E ADAMS BLVD	90011	9	120A207    46	5127037011	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.02435	-118.26718	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42589	14041-20000-04357	5161 N LANKERSHIM BLVD	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.16452	-118.37469	pc for t24 energy only. new restroom lightin on all floors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42590	18041-20000-44609	9140 N LURLINE AVE	91311	12	198B109   129	2748001034	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.23663	-118.58406	P.C POWER AND T-24 FOR A MANUFACTURING FACILITY POLMER CONCERETE. CHECK FOR HAZARDOUS. EXISTING 4000AMP-480/277V,3PH,4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42591	19041-20000-38060	5127 N DUMONT PL	91364	3	171B109   256	2166016004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Issued	09/23/2019 12:00:00 AM	ADDRESS	34.16287	-118.58109	Plan check for PV roof mounted system, PV system size: 15.435KW DC, 11.4KW AC CEC with 49 PV modules and 2 inverters(3.8 and 7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42592	17041-10000-41639	8643-8645 N DARBY AVE	91325	12	195B125   941	2786004009	P-1VL, [Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			PC Info Complete	01/16/2018 12:00:00 AM	ADDRESS	34.22762	-118.53401	Power plan check only for a service upgrade of 800 Amp, 120/240V consists of (2) 400 Amp meter section for (2) building sharing a common wall. Scope only consists of 800A service with (2) 400A MSP, and (6) 200A panelboards. All loads and its circuitry are not part of this scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42593	12041-10000-05135	454 S DALEHURST AVE	90024	5	138B153   236	4359005009	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			PC Approved	04/11/2012 12:00:00 AM	ADDRESS	34.07357	-118.43513	PLAN CHECK FOR ROOF-MOUNTED 8.5KW PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. PERMIT WAS OBTAINED ON 12041-10000-03888	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42594	14041-20000-35562	5421 N PENFIELD AVE	91364	3	171B113    37	2166003008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.16871	-118.56863	PC FOR PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. DOWNSIZING MAIN BREKER. SYSTEM USES POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42595	18041-20000-08994	23535 W HATTERAS ST	91367	3	174B093    69	2041004016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	06/25/2021 12:00:00 AM	ADDRESS	34.17564	-118.63964	PLANCHECK FOR POWER . ADDING NEW GUEST HOUSE INSTALL 600A SERVER EQUIPMET SUPPLY EXISTING UNIT AND GUSTHOUSE.THIS IS PERMIT COVER 600A SERVICE AND PANELBOARDS ONLY. BUILDING PERMIT # 17014-30000-02974New detacheed accessory living quater.PERMIT FEES FOR GUEST HOUSE PAID UNDER COMBO PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42596	13041-10001-34377	20330 W VIA MEDICI	91326	12	219B113   126	2701045007	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.29433	-118.57714	Expedited RSES plan check per applicant request.{{{PV1, install 11 kw DC roof-mounted solar array for a 2-story house, interconnect with main panel. (2)Transformerless inverter(s): Solaredge SE3800A-US and Solaredge SE6000A-US. (44) modules: Trina Solar TSM-250PA05.18.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42597	14041-10000-03883	947 W STATLER ST	90731	15	024B197    57	7442003010	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	33.76399	-118.29913	PV1, Install 4 kW DC roof-mounted solar array on a two-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) Modules: CANADIAN SOLAR CS6P-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42598	17041-20000-39587	7631 W WILLOW GLEN ROAD	90046	4	153B173    59	5569003004	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.11877	-118.36707	new 2-story single family dwelling 600 amp service.  plan check for power only.  permit fees under combo permit building application number 15010-30000-04116	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42599	17041-10000-30051	1920 N WHITLEY AVE	90068	4	150A187   149	5575005007	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			08/23/2017 12:00:00 AM	03/08/2022 12:00:00 AM		Issued	03/08/2022 12:00:00 AM	ADDRESS	34.10591	-118.33321	FULL PC FOR POWER AND ENERGY FOR A NEW 4 STORY APARTMENT WITH ROOF DECK OVER 2 LEVEL  OF SUBTERNEAN GARAGE. SCOPE INCLUDES A NEW 1200A 120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD/SERVICE(4 TYPICAL UNITS ON THE PLANS).. TOTAL AFFECTED AREA IS 15,185 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42600	17041-20002-35687	3746 N HAWLEY AVE	90032	13	159B205   752	5594010016	(Q)RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM			PC Approved	02/07/2018 12:00:00 AM	ADDRESS	34.09066	-118.19042	Revision to approved set of plans.  Reduction of system size from (14) to (9) modules and 3.8 kW rated string inverter to 3.0 kW rated string inverter.  $0 plan check fee per State Senate Bill SB 1222. (((PV1Install roof mounted PV system sized 3.8kW with powerwall (battery back-up) interconnected with MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42601	17041-10000-06224	2029 S CENTURY PARK EAST 15th FL-CORRIDOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Issued	02/28/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY ONLY (ALTERATION). INTERIOR RENOVATION OF PUBLIC LOBBY ON THE 15TH FLOOR, CORRIDOR . AFFECTED AREA 1670 SQ FT. EMERGENCY LIGHT IS NOT PART ON THIS SCOPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42602	19041-20000-40379	18443 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42603	17041-20000-24798	17511 W MAYALL ST	91325	12	204B129   377	2734016007	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.2541	-118.5162	PV1.  Install 9.98 kW roof mounted grid tied PV system  (36) modules with (2) Enphase IQ6 and (34) Enphase IQ6+ microinverters.  Derated main breaker.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42604	13041-20000-33983	4221 W WILSHIRE BLVD SUITE 224	90010	4	132B189    20	5504001014	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.06194	-118.32113	T24 FOR EXISTING OFFICE. SCOPE OF WORK ON SUITE 224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42605	10041-20001-25115	8275 W BEVERLY BLVD	90048	5	138B173   394	5514009051	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.07623	-118.36982	Supplemental application to approved plans. Revision to include additional ckts installed and T24 energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42606	19041-10003-18417	930 S HILGARD AVE Level-2	90024	5	135B153   541	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM			Corrections Issued	11/22/2019 12:00:00 AM	ADDRESS	34.06306	-118.44116	PLAN CHECK ONLY. RE-PLAN CHECK TO APPROVE AND RESTAMP A LOST SUPPLIMENTAL UNDER APPLICATION NUMBER 19041-10001-18417 WHICH WAS SUBMITTED FOR T-24 CHANGES TO AN APPROVED SET TO INCLUDE LOWER FIXTURE WATTAGE (LF-18), ADDITION OF 1 96W POWER SUPPLY  AND REDUCE THE COUNT OF FIXTURE LF-3. SCOPE ALSO INCLUDE NEW 9KVA TRANSFORMER AND PANEL FOR AUDIO AND VISUAL CIRCUITS. ALL CHANGES ARE MARKED BY DELTA 1PERMIT FEES ARE UPDATED AND PAID UNDER MASTER APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42607	18041-10002-12963	5156 S BRYNHURST AVE	90043	8	108B185   121	5013007015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	33.99513	-118.33314	DELTA 3 CHANGES TO AN APPROVED SET OF PLANS. REMOVING THE EXISTING METER SOCKET. PC ONLY____________________________________________________________________________((ORIGINAL SCOPE)): PV1. ADDING A NEW STRING OF MODULES FOR AN EXISTING PV SYSTEM. SCOPE INCLUDES ADDING 7 MODULES. ADDING 1.96KWdc TO AN EXISTING 3.06KWdc PV SYSTEM. TOTAL DC WATTAGE FROM EXISTING AND NEW IS 5.02KWdc.  THE AC SYSTEM SIZE REMAINS 3.6KWac. (7)MODULES-Q-CELLS # Q. PLUS-G4.1/SC-280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42608	16041-20000-39851	4522 W LEXINGTON AVE	90029	13	144B197   313	5542026021	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Apartment			11/10/2016 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.09334	-118.28738	Plan check for power and energy. Project site is a new 3-story apartment building: 2 levels of residential over 1 level of parking garage. Total lighting area = 7,857 sq. ft.Note: Building application has been created under 16010-10000-04656	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42609	19041-20000-33380	4424 E SINOVA ST	90032	14	145-5A229 287	5302029030	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.09144	-118.19017	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM TO EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK CONSISTS OF (1) BATTERY AND A PANEL. SYSTEM SIZE IS 13.2 KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42610	15041-10001-03744	555 S FLOWER ST Floors 27-28	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			PC Info Complete	06/16/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	Modification to an approved set with new circuits and existing circuits call out;  minor changes also added  to lighting plan. Note. All changes are under delta-8 only.(((Full plan check for an office T.I  ( 27th & partial 28th floor), total area 17920 SQ feet.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42611	15041-20000-25051	16940 W KNOLLWOOD DR	91344	12	216B133   401	2610001002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.28761	-118.50039	Plan check for a PV1 roof-mounted PV system. System size is 11.3 kWac and consists of (2) inverters, (36) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42612	13041-10000-15518	6301 W 3RD ST unit s-10	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/28/2013 12:00:00 AM	ADDRESS	34.07243	-118.35963	Ti, for rtail at the grove, title 24, lighting, emergency lighting, and additional time for consultation fees.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42613	14041-20000-14197	333 S HOPE ST E LEVEL	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.05326	-118.25292	Renovation of restrooms on 2nd floor of (E) highrise commercial office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42614	18041-20000-02419	1647 S HAYWORTH AVE	90035	10	129B173  1380	5068019026	R2-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.04638	-118.36917	Plan check for the addition battery back-up system onto an existing PV1 roof-mounted PV system. Existing PV system size is 3.3 kWac and is interconnecting with a 200 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42615	18041-10000-32761	7660 W WYNGATE ST	91042	7	204B197   575	2558008016	RD5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Issued	08/28/2018 12:00:00 AM	ADDRESS	34.25735	-118.29991	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42616	18041-10000-43524	10215 N BALBOA BLVD	91325	12	204B133   272	2694001053	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	34.25589	-118.50256	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42617	16041-20000-35373	10054 N GOLDEN OAKS AVE	91042	7	202-5A203 436	2570008054	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.25084	-118.27786	pv1install roof mounted pv system sized 3kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42618	15041-10003-28085	4226 E VERDANT ST	90039	13	159B205   455	5594006029	[T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.13138	-118.26456	DELTA 8 CHANGES TO PERMITTED SET OF PLANS- ADDED FEEDER AND 75KVA TRANSFORMER TO SUPPLY 200A PANEL AND NEW BRANCH CKIS((((((((Full plan check for a new SUNDAY SCHOOL, CLASSROOMS, MULTI-USE BUILDING ACCESSORY TO CHURCH BUIDING. Scope include (1) 3000-Amp 480/277V 3-phase service, (11) panels with (183) circuit and total of 48,136-SQ feet for T24.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42619	14041-10000-03645	6216 N CARTWRIGHT AVE	91606	2	177B177   239	2414017004	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.18358	-118.36366	PV1, roof-mounted solar installation, to interconnect with (E) 200A main service. system sized @ 5.5 kW DC, with (22) modules & optimizers (OP250-LV) , (1) SE5000-US-ZB-U solar edge inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42620	15041-20000-30085	11780 W GARBER ST	91342	7	213B169   718	2530004022	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.27847	-118.38909	Plan check for a Pv1 roof-mounted PV system. System size is (3) kWac and consists of (1) inverter and (10) modules. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42621	13041-10001-15767	430 S BROADWAY	90013	14	129A211    57	5149024008	[Q]C4-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			03/24/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Closed	06/25/2015 12:00:00 AM	ADDRESS	34.04864	-118.24991	"PLAN CHECK FOR POWER, REFEEDING TWO ELEVATOR. ADDING A NEW FIRE PUMP.NEW 600 A DISTRIBUTION BOARD.{{{{{{conversion of retrofit building to 58 UNIT MIXED USED BUILDINGATTACHED TO THE PLANS ARE MODIFICATIONS OF BUILDING ORDINANCES FOR THE BUILDING TO KEEP ITS ""NON-HIGH RISE STATUS"" MODIFICATIONS WERE DATED May 9th 2013 and signed by Jameson Lee}}}"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42622	15041-20000-09190	6250 N TOPANGA CANYON BLVD #F-1545	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for power and Title-24 (energy).  Total area = 4,484 sq. ft.T.I. to commercial space.  First time tenant.  Three new panels and one 75 kVA transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42623	15041-10000-30336	1658 E VERNON AVE	90011	9	112-5A213  82	5106003022	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	10/03/2015 12:00:00 AM	ADDRESS	34.00368	-118.24423	Standdard plan PV1 3.0KW AC roof-mounted system with (8) Kyocera KU265 modules and (1) ABB-PVI-3.0 inverter inter connecting through the main service panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42624	19041-10000-23651	6201 E STRICKLAND AVE	90042	14	159A231   299	5482007018	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	02/08/2020 12:00:00 AM	ADDRESS	34.12826	-118.18489	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 21 MODULES (REC285TP2), 21 OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTER (SE5000H). SYSTEM SIZE IS 5.985KWdc AND 5KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42625	13041-20000-13780	10700 W SANTA MONICA BLVD	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.05167	-118.432	First time tenant, Full Plan Check.  New Restaurant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42626	19041-10000-28139	214 S WESTMORELAND AVE	90004	13	135B197    84	5501020014	R3-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM			PC Approved	07/22/2019 12:00:00 AM	ADDRESS	34.0698	-118.28773	PC for Methane mitigation system, 1 panel and 30 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42627	19041-10000-36434	515 S FLOWER ST #4150	90071	14	130-5A209 125	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC FOR ENERGY OFFICE T.I. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. PERMIT INCLUDES LIGHTING CIRCUITS ONLY. TOTAL SQ. FT. 8073.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42628	17041-10000-21265	2700 S WESTERN AVE	90018	8	123B193   897	5053010001	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.03074	-118.30877	T24 ONLY - REPLACEMENT OF EXISTING LIGHT FIXTURES WITH (7) LED FIXTURES.  TOTAL AFFECTED AREA =  4775 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42629	15041-20000-38886	3770 N CAHUENGA BLVD	91604	4	162B177   423	2425001069	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.13641	-118.3623	PLANCHECK FOR T24 ENERGY. OUTDOOR FACADE LIGHTING FOR CARLS JR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42630	18041-10000-03406	8106 N LANKERSHIM BLVD	91605	6	189B169    62	2311005040	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.2179	-118.38758	REPLACE INDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42631	17041-20001-35692	2731 N EDWIN PL	90046	4	156B169   284	5564001019	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.12249	-118.38859	expeditepv1install roof mounted pv system sized 7.6kw with tesla powerwall interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42632	16041-20000-41057	14832 W GILMORE ST	91411	6	180B149   708	2236020006	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.18747	-118.45644	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP AND 22 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42633	11041-10000-18514	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	12/05/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	REPLACEMENT OF OUTDOOR LIGHTING AT KAISER PARKING STRUCTURE, WALKWAYS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42634	16041-20000-17722	12100 W OLYMPIC BLVD SUITE 150	90064	11	123B149   575	4259025019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.03215	-118.45396	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SUITE 150 IN RIOT GAMES OFFICE. 7913 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42635	14041-20001-32638	715 N RIDGEWOOD PL	90038	13	141B189   251	5535002023	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	34.08399	-118.31475	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42636	19041-10000-51219	5054 N MECCA AVE	91356	3	171B125   768	2184001030	RA-1	South Valley	Encino - Tarzana	Tarzana		1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	05/22/2020 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.16235	-118.53733	(E-PLAN) $0 permit fees due, per Assembly Bill 1414.NEW PV1 INSTALLATION FOR AN EXISTING SERVICE OF 400 AMPS. INSTALLATION INCLUDES 45 MODULES (POWERXT-360R-PD), 45 OPTIMIZERS (P400), 2 CENTRAL INVERTERS (SE7600H-US), 2 ENERGY STORAGE SYSTEM, AND 2 PANELS OF 200 AMPS. SYSTEM SIZE: 16.2 KW DC; 15.2 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42637	17041-10000-03354	13213 W ROSE AVE	90066	11	114B149   484	4244004024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.00899	-118.45386	PC FOR A ROOF-MOUNED PV SYSTEM WITH BATTERY STORAGE.  INVERTER SIZE 7.6KW AC USING TESLA POWER WALL. BACKFEED UTILITY WITH BACK UP LOAD CENTER INSTALLED AS WELL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42638	11041-10000-17230	3041 W 7TH ST	90005	10	132B197   169	5077011018	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Apartment			08/15/2011 12:00:00 AM	05/15/2012 12:00:00 AM		Permit Closed	04/19/2013 12:00:00 AM	ADDRESS	34.05992	-118.29006	New 133 unit residential building.  Building is 4 story plus subterenean garage.  Plan check is for energy and power.  Fire alarm will be submitted separately.  NOTE TO PLAN CHECKER:   Applicant brought a pre-printed check.  Verify fees during the plan check process.  The circuits were adjusted to meet the amount required by the applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42639	14041-10001-11214	4323 N LAURELGROVE AVE	91604	2	165B165   564	2367002039	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	05/12/2014 12:00:00 AM	ADDRESS	34.1492	-118.40097	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER(S): SOLAREDGE  SE3800A-US-ZB-U(14) MODULES: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42640	10041-20000-21858	5900 W WILSHIRE BLVD #110	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/05/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.06237	-118.35809	T.I. to existing restuarant of a high rise building in the floor floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42641	10041-10000-19753	5901 W VENICE BLVD	90034	10	126B173  3008	5066016037	C2-1, R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Public Safety Only			10/05/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	01/28/2011 12:00:00 AM	ADDRESS	34.04	-118.37016	REPLACING FIRE ALARM SYSTEM AT A RADIO STATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42642	16041-10000-04801	5321 S VERMONT AVE	90037	9	108B197   549	5002026006	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	33.99349	-118.29169	T-24, TI TO AN (E) DONUT SHOP. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1595	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42643	17041-20000-03306	4101 S REDWOOD AVE	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	33.99086	-118.44043	Plan check for power only. Installing (2) new 1600A services for commercial buildings. One serves buildings 3,4 and 5. The other serves building 6. Install new distribution equipment and feeders - no circuits. Service equipment outside of building 6. Building 6 have an addition, and also are changing use from manufacturing to office. Building permit application #16014-20000-04557.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42644	16041-20001-21799	10646 W STALLION RANCH ROAD	91040	7	204B177   255	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.25903	-118.36199	RSES expedited plan check per applicant request.  PV1.  Install roof mounted PV system.  (86) modules with microinverters.  (1) solar monitoring circuit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42645	16041-10000-18232	8500 N BALBOA BLVD	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.22485	-118.50045	PC FOR ENERGY AND POWER. SITE UPGRADES TO EXISTING OFFICE/INDUSTRIAL CAMPUS.  INCLUDES: NEW SIDEWALK FOR ACCESSIBLITY COMPLIANCE; IMPROVEMENTS FOR VEHICULAR/PEDISTRIAN EFFICIENCY; PARKING RESTRIPING; SITE LIGHTING; LANDSCAPE AMENITY AREAS; AND RELOCATION OF SITE DRIVEWAY ENTRIES. TOTAL AREA 619117 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42646	18041-10001-44011	6390 W DE LONGPRE AVE	90028	13	147A187   290	5546016002	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM			PC Approved	10/17/2019 12:00:00 AM	ADDRESS	34.09602	-118.32852	DELTA 2(BULLETIN 2.3)  AND 3(BULLITIN 3) CHANGES TO AN APPROVED FOR NEW DISTRIBUTION SYSTEM  -  CHANGES TO FIXTURE SCHEDULE, FIRE PUMP CUTSHEET, FEEDER SCHEDULE, SINGLE LINE DIAGRAM, LOAD CALCULATION, EQUIPMENT LOCATION AND T-24. ALL CHANGES ARE CLOUDED AND A DETAILED NARRATIVE IS SUBMITTED FOR EACH BULLETIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42647	15041-10000-02684	4433 S ALAMEDA ST	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.00295	-118.23924	Plan check for Title 24 only. Project is a TI for a retail store. Total lighting area = 682 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42648	14041-20000-05348	10100 W VENICE BLVD SUITE 1000	90232	5	120B165  1282	4208002019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	ADDRESS	34.0221	-118.40033	PC FOR T24 ENERGY ONLY. EXISTING OFFICES NEW LIGHTING. TOTAL AREA 1350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42649	14041-10000-34822	1842 N CHEROKEE AVE	90028	13	150A185   300	5547004019	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			12/16/2014 12:00:00 AM			PC Info Complete	06/13/2016 12:00:00 AM	ADDRESS	34.1044	-118.33463	Power plan check for  (8)  guestrooms located at the basement from  a 5-story apartment with new service upgrade from 400-Amp to 600-Amp. all (8) guestrooms are typical.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42650	17041-10000-37532	22350 W JAMES ALAN CIR	91311	12	204B101    88	2723008***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	Apartment			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Issued	10/18/2017 12:00:00 AM	ADDRESS	34.25871	-118.61266	PC for rooftop PV for SFD. Installing new 6.03kWsolar system with 18 AC modules and 100A load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42651	11041-10000-10566	4632 W SANTA MONICA BLVD	90029	13	144B197   734	5539003014	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.09073	-118.29041	NEW 800 AMP SERVICE TO EXISTING SINGLE STORY RETAIL BUILDING.  CUSTOMER REQUESTS PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42652	17041-20001-15142	5216 W VENICE BLVD	90019	10	126B177   276	5064002008	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.04436	-118.35487	Remodel of (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42653	16041-20000-27940	718 S MATEO ST	90021	14	124-5A217 303	5166015008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.03393	-118.23212	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total outdoor lighting area = 8,817 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42654	18041-10002-26724	10408 N BALBOA BLVD	91344	12	204B133    17	2684012038	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Approved	08/06/2018 12:00:00 AM	ADDRESS	34.25952	-118.50211	Expedite per applicant request.(((Plan check for a 50KW AC PV2 roofmounted system with (156) modules and (1) 50KW inverter interconnecting throuth the subpanel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42655	19041-10000-11460	727 W 167TH ST	90247	15	066B197    33	6121006040	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	33.87999	-118.28781	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 29 MODULES (PHONO PS325P), 29 OPTIMIZERS (SE P370) AND 1 CENTRAL INVERTER (SE7600H-US). SYSTEM SIZE IS 9.43KWdc AND 7.6KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42656	13041-10000-30875	13180 W SAYRE ST	91342	7	228B157   463	2511020020	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.32225	-118.41998	PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 23 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42657	19041-10000-30856	9757 N ARLETA AVE	91331	6	201B157   468	2621010020	[T]R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.24702	-118.43163	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42658	15041-20000-31456	877 E MONTECITO DR	90031	1	144A227   309	5304012034	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Expired	10/23/2017 12:00:00 AM	ADDRESS	34.08891	-118.19912	PV1. Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (22) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42659	14041-10000-34318	1340 E 16TH ST	90021	14	121-5A211 370	5130015006	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.02557	-118.24769	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3368 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42660	15041-20001-42329	14832 W HESBY ST	91403	4	171A149   243	2263030031	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.162	-118.45636	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.0KWac/13.407KWdc.(41) MODULE-SUNPOWER SPR-327NE-WHT-D(2)INVERTER-SUNNYBOY SMA SB6000TL-US AND SMA SB70000TL-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42661	19041-20000-50108	8306 N NESTLE AVE	91325	12	192B125   650	2786014024	RS-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.22125	-118.53049	PV1.  Install 3.78 kW roof mounted grid tied PV system with 13.5 kWh energy storage system.  (12) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42662	13041-10000-35323	1900 S AVENUE OF THE STARS STE 1400	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for T24 and emergency lighting. Area 20184 sq ft.Suit  # 1400 , high rise.  TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42663	14041-10000-35370	200 WORLD WAY TERMINAL2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	NEW 1240 SQ FT RESTAURANT IN LAX TERMINAL 2.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42664	19041-10000-19145	937 N SYCAMORE AVE	90038	4	144B181   686	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.08824	-118.34291	NEW EXTERIOR LIGHTING FOR FACADE AND WALKWAY FOR A WAREHOUSEPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42665	18041-10000-33311	5721 N VAN NUYS BLVD	91401	4	174B149   504	2244028024	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.17448	-118.44905	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42666	14041-10001-21169	11105 N MCVINE AVE	91040	7	210B193   439	2551045001	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			Verifications in Progress	09/19/2014 12:00:00 AM	ADDRESS	34.27066	-118.31163	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 4.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: TRINA SOLAR TSM-255PA05.18(1) INVERTER: SOLAREDGE SE5000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42667	16041-10000-10960	101 S THE GROVE DR K4	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.07256	-118.35874	T-24, CHANGE OF USE OF KIOSK FROM RETAIL TO TAKE OUT JUICE SALES. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL SQ. FT. 188.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42668	17041-10001-20050	753 N ORANGE DR	90038	5	141B181   333	5525007027	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM			PC Approved	06/17/2017 12:00:00 AM	ADDRESS	34.08494	-118.34172	Expedite fees only.       Installation of new roof mounted solar PC system with battery back up on eixsitng single family dwelling.  Central inverter with 2 Tesla AC Powerwall 5.8 kVA / 13 kWH batteries.  Total system size = 3 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42669	19041-10000-06511	1525 W COLORADO BLVD	90041	14	162A227    32	5669012012	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	12/09/2021 12:00:00 AM		Issued	12/09/2021 12:00:00 AM	ADDRESS	34.13963	-118.19903	Full plan check for power and energy for a new 6 unit 4 story apartment building with 5 commercial unit/space. No lighting & power is provided for he commercial space, just conduit only from the service equipment. SERVICE 600A , 120/240V, 1PH.B# 18010-10000-04628	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42670	19041-10000-51417	57 E MARKET ST	90291	11	108A143   429	4226007009	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			Reviewed by Supervisor	01/28/2020 12:00:00 AM	ADDRESS	33.98811	-118.47335	POWER PLAN CHECK FOR INSTALLATION OF A BATTERY BACKUP SYSTEM TO EXISTING 8 KW PV2 IN AN APPARTMENT/STUDIO TO SERVE EM POWER. EXISTING SERVICE SIZE IS 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42671	12041-10000-26039	601 W 5TH ST	90071	9	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.05049	-118.25386	Ti in an existing office Bldg. EPC for T24 & emergency lights. Existing ckt and panels. (9th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42672	18041-10000-21492	10605 N REDMONT AVE	91042	2	207B197  1118	2566016037	R1-1	North Valley	Sunland-La Tuna Cyn-Lakevw Ter-Shadow Hls-Tuj			1011.10	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.26152	-118.29247	Install New PV1 rooftop solar system, 3.8 kW AC with (11) AC modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42673	18041-20000-12200	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Issued	04/04/2018 12:00:00 AM	ADDRESS	34.25052	-118.51258	Plan check for PV roof mounted system to existing PV system. New PV system addtion to existing: 6.0kW and 24 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42674	17041-10000-34758	1910 E OLYMPIC BLVD	90021	14	121-5A215 121	5166025005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.027	-118.2375	PC for power and energy for new three story warehouse building. PC for new 240/120V 800A service. Installing new switchboard, panels, circuits, equipment, lights, elevator. Total area Indoor+Outdoor=115686sqft.B#17010-10000-01373.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42675	15041-10000-04476	4920 N BALBOA BLVD	91436	5	168B133    77	2259010001	C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	PIN	34.15988743	-118.50066576	Plan check for power and energy. TI for new restaurant replacing a different restaurant. Total area = 1627 sq. ft. title 24 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42676	16041-20000-22729	365 N WILTON PL	90004	4	138B189   161	5522029002	R1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.07772	-118.31365	PV1.  Install 8.6 kW roof mounted PV system.  Central inverter standard plan.  (1) 4.6 kW and (1) 4 kW rated central inverters with (33) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42677	10041-20000-03158	15305 W LANARK ST	91406	6	189B145    41	2654037029	R4-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Apartment			02/23/2010 12:00:00 AM			PC Approved	02/26/2010 12:00:00 AM	ADDRESS	34.21785	-118.46738	Delta 5 revisions to 08041-10000-17667	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42678	18041-20000-23220	22641 W OXNARD ST	91367	3	177B097   482	2039017023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.17931	-118.62026	Plan check for a PV1 roof-mounted PV system. System size is 30.4 kWac and consists of (3) inverters, (91) modules, and (2) load centers.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42679	18041-20002-35448	11420 N MONTALCINO WAY	91326	12	213B109   404	2701068015	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.2789	-118.58643	12-17-2018 Changes to approved plans, relocation of critical loads from (N) 200A subpanel to (E) 125A subpanel reconnected to backup gateway.  (((11-30-2018 Changes to permitted set of plan, changes include update as build existing service panel 200A. Changes has been clouded. Plan check only)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42680	13041-20000-10676	7606 N FALLBROOK AVE STE 11-STE 13	91307	3	186B097   194	2013008054	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	PIN	34.20860599	-118.62297665	Full plan check for dental office. Suites 11, 12, 13. Dr. Ali Saeghi	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42681	11041-10000-03051	1605 W CARSON ST	90501	15	051B193   911	7349033034	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			02/16/2011 12:00:00 AM			Corrections Issued	03/15/2011 12:00:00 AM	ADDRESS	33.83165	-118.30675	FULL PLAN CHECK.  TI FOR AN EXISTING SINGLE STORY GAS STATION BUILDING.  NO CHANGE IN USE.  UPGRADE SERVICE TO 600 A, NEW PANEL, NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42682	12041-10000-08494	4157-4163 1/2 W BEVERLY BLVD	90004	13	138B197   270	5520025005	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM	05/15/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.07642	-118.29977	Tenant improvement, exist. 2-story multi-tenant  bldg., partial change from office to retail, multi-addresses.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42683	16041-10002-14029	10561 W PICO BLVD	90064	5	126B157   249	4315005003	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.04431	-118.42087	PC FOR CHANGES TO APROVED SET. PROVIDED ROOM FOR ELECTRICAL MAIN AND UPDATED NOTES ON HIGH LEG. PROVIDED PLAN FOR ELECTRICAL ROOM AND UPDATED T24 PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42684	16041-20000-16192	15724 W HARTSOOK ST	91436	5	171B141   196	2261002016	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.16377	-118.47587	PV1INSTALL ROOF MOUNTED PV YSTEM STANDARD PLAN.  SYSTEM SIZE 7.7KW INTERCONNECTED WITH MSP.(36) ENPHASE 215 MICROINVERTERS(36) SOLAR WORLD SW280 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42685	17041-10000-11321	4409 W ADAMS BLVD	90016	10	123B185   655	5050010052	[Q]C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2187.02	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.03275	-118.3355	PC for energy only, outdoor T-24. Removing HID fixtures and replacing them with new LED ones. Area: 48,600.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42686	14041-20000-06017	6502 N DEMPSEY AVE	91406	6	180B141   681	2233004012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.18863	-118.47538	Roof mounted PV system with 4.5KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42687	14041-10000-13142	9901 N DRONFIELD AVE	91352	7	201B173   181	2538024901	OS-1XL-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.24936	-118.37489	PERMIT TO BE PULLED AT EPC COUNTER ONLY. PLAN CHECK FOR ENERGY ONLY. TI (E) STONEHURST REC CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42688	18041-10000-46753	400 N MARINE AVE	90744	15	030B205  1269	7418014009	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM			PC Info Complete	04/17/2019 12:00:00 AM	ADDRESS	33.77446	-118.26314	Full PC FOR A CHANGE OF USE FROM WAREHOUSE & MANUFACTURING TO INDOOR NURSERY AND OFFICE. SCOPE OF WORK INLCUDES NEW 1200AMP SERVICE, LIGHTING AND CIRCUITS. TOTAL SQ. FT. 13,120.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42689	11041-10002-14814	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM			PC Approved	12/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN REVIEW OF RFI FILES FOR CHANGES ON SITE DURING THE BRADLEY WEST CORE RENOVATIONS- CHANGES INCLUDE REFEEDING LOADS FROM THE SAME PANELBOARD BUT USING DIFFERENT CIRCUIT DESIGNATIONS OR FROM NEARBY PANELBOARD.CHANGES ARE CLOUDED.Renovation and addition to existing Tom Bradley International Terminal building, LAX.  PLAN CHECK IS FOR POWER AND ENERGY.   FIRE ALARM IS ON A SEPERATE APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42690	16041-20000-04377	1950 S MARIPOSA AVE	90007	1	126B197   853	5075031021	R3-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.03898	-118.29822	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (16) modules, (16) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42691	17041-10000-23261	6552 N LANKERSHIM BLVD	91606	2	180B169   642	2335009001	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.19006	-118.38758	Title 24 plan check.  Replace HID fixtures with new LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42692	19041-20000-19305	23115 W OSTRONIC DR	91367	3	171B097   466	2042014035	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.16554	-118.6304	PV1.  Install 12.5 kW DC / 10.62 kW AC roof mounted grid tied PV system.  (41) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42693	18041-10001-47349	2218 W LOVELAND DR	90065	1	151-5A219  70	5462018012	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.11091	-118.22371	Suppl App to replace the lost plans.  Plan check only.  Permit was issued under: 18041-10000-47349.<<<<Plan check for a PV1 8kW AC roof  mounted system with (25) AC modules interconnecting through a subpanel.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42694	14041-20000-00265	810 S KOHLER ST	90021	14	124-5A213 400	5146018001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.03445	-118.24503	INSTALLING NEW EXIT SIGNS FOR NEW OPENINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42695	17041-10000-44939	11150 W OLYMPIC BLVD #790	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.03956	-118.43857	PC for T24 only for new lighting in office TI. Installing new lights and controls. Total area is 2043sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42696	16041-20001-37972	20133 W VIA CELLINI	91326	12	219B113    28	2701039017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2016 12:00:00 AM			PC Approved	10/29/2016 12:00:00 AM	ADDRESS	34.29398	-118.57182	RSES expedited plan check fee per applicant request.  PV1.  Install 9.64 kW DC roof mounted grid tied PV system.  (33) modules with Enphase S280 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42697	13041-20000-10361	9220 W LA TUNA CANYON ROAD	91352	2	198B185    77	2401036007	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.23624	-118.33411	New 9.36kw rooftop PV System for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42698	11041-10000-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	33.94386	-118.4047	core and shell plan review for the central utility plant at LAX airport	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42699	14041-10001-13826	3287 N VELMA DR	90068	4	159B181   125	5579007007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.13409	-118.34515	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.[[PV1, INSTALL 5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42700	18041-10000-35581	515 S FIGUEROA ST #1600	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLAN CHECK FOR TITLE 24 ONLY FOR - Interior tenant improvement to (E) Office (16TH FLOOR - HIGHRISE BUILDING) - TOTAL AFFECTED AREA = 1080 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42701	18041-10000-46198	10419 W VENICE BLVD SUITE 110A	90034	5	117B165    56	4314003039	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM			PC Approved	05/01/2019 12:00:00 AM	ADDRESS	34.02047	-118.40461	PC FOR TITLE 24 ENERGY ONLY FOR RESTAURANT TI.SCOPE INCLUEDS NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTING. TOTAL AFFECTED AREA 1314 SQ.FT.b# 18016-10000-39010	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42702	13041-20000-33891	4032 N MURIETTA AVE	91423	4	162B153   147	2272012007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.14324	-118.43593	PV1 SINGLE FAMILY DWELSING. TOTAL SYSTEM SIZE 3.4KW AC USING 16 MODULES. ENPHASE M215 MICROINVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42703	18041-10000-43562	6516 W SELMA AVE	90028	13	148-5A187 331	5547017008	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/08/2022 12:00:00 AM	ADDRESS	34.09965	-118.33163	NEW 9 STORY, 212 GUESTROOM, HIRISE HOTEL AND 4 BASEMENT LEVELS OF PARKING. NEW 2500AMP 277/480V SERVICE, 4 25HP ELEVATORS, 400KW GENERATOR, 190HP FIRE PUMP, ETC. FULL PLAN CHECK FOR POWER AND ENERGY. BULDING PERMIT: 16010-10000-03901.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42704	17041-10000-21826	227 S GAREY ST	90012	14	129A215   251	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.04634	-118.23533	Plan check for power and Title 24.  Renovation of existing restaurant space.  New 350 kVA transformer and 800 amp distribution board with 5 subpanels feeding new lighting, receptacles, and HVAC.  Lighting area = 4,123 sq. ft. (indoor) + 1,042 sq. ft. (outdoor)     Building permit #17014-10000-03010	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42705	11041-10000-25118	120 W C ST	90744	15	027B205   188	7418032903	[Q]CM-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	33.77252	-118.26268	PLAN CHECK POWER AND ENERGY FOR NEW PORT POLICE DOG KENNEL FACILITY. SITE IN METHANE ZONE. EXISTING SERVICE SUPPLYING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42706	19041-10000-30384	333 S HOPE ST 19TH FL	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.05326	-118.25292	ENERGY ONLY PC FOR INTERIOR OFFICE REMODEL (HIGHRISE- 19TH FLOOR). SCOPE OF WORK AREA 17,885SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42707	19041-10002-03628	1241 S SOTO ST	90023	14	121-5A221 114	5170017030	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.02743	-118.21975	Change to an approved set delta 2 only, change include swapping location of Disconnect switch and meter per LADWP only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42708	13041-20000-19313	1136 S PLYMOUTH BLVD	90019	10	129B185   407	5082017008	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Expired	08/28/2015 12:00:00 AM	ADDRESS	34.05169	-118.32866	New 6.0kw Roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED and uses Enphase Microinverters. 200A service upgrade has been included in permit fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42709	11041-20000-16451	12910 W CULVER BLVD A-E	90066	11	105B157   578	4221031006	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	33.98314	-118.42695	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT OFFICE. PERMIT FOR ELECTRICAL WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42710	11041-10001-10270	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.14947	-118.43885	PLAN CHECK FOR MODIFICATION TO APPROVED SET OF PLANS. DELTA R1 CHANGES ONLY. NEW PANELS, EQUIPMENT, AND BRANCH CIRCUITS ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42711	14041-10000-11994	8500 W BEVERLY BLVD SUITE 601A	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLAN CHECK FOR ENERGY ONLY FOR EXISTING RETAIL SPACE. SCOPE OF WORK IS ON SUITE 601A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42712	15041-10000-30521	12696 W MILLENNIUM	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	33.9764	-118.41495	PV1 4kW AC (AC MODULE) roof-mounted system with (16) modules and one load center interconnecting through the main service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42713	19041-20001-32291	8410 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM				10-11-2019 Changes to an approved set of plan, changes include relocate PV disconnect, Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42714	16041-10001-30643	835 W JEFFERSON BLVD 7-D	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	34.02411	-118.28451	PC ONLY. CHANGES TO APPROVED SET OF PLANS. REMOVAL OF RESTROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42715	14041-20000-11785	7225 W HOLLYWOOD BLVD	90046	4	147B181    96	5548001018	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Apartment			05/02/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.10174	-118.34715	TI-24 - ENERGY PLAN CHECK ONLYApartment building, renovation of 1st floor lobby and side office - 966sqft. New lighting. Existing emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42716	16041-10000-27027	2372 W LOMA VISTA PL	90039	13	147A209   398	5422011008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.09557	-118.25814	PV1, INSTALL NEW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE 2.6 kW DC (10) MODULES: HYUNDSAI HIS-S260RG(BK) 260 W(10) MICRO INVERTERS: ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42717	19041-20001-24367	14706-14708 W ARMINTA ST	91402	6	189B149   517	2210021021	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.2133	-118.4533	Supplemental plan check for change to approved set. Addition of two sub panels and relocation of loads and minor change to floor plans. Clouded delta 2 changes only.OriginalPlan check for power only. Service upgrade to 800A Over Head 120/240V 3 Phase 4 wire.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42718	12041-20000-09509	5240 N LANKERSHIM BLVD #101	91601	4	171B173  1387	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	ADDRESS	34.16613	-118.3751	"TENANT INTERIOR SPACE ALTERATION TO A NEW SHELL BUILDING; RESTAURANT.  ""COMPLY WITH DEPARTMENT ORDER effective date 12/27/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42719	14041-20000-06510	11425 N DEBRA AVE	91344	12	213B137   773	2681002006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.27797	-118.49017	Roof mounted PV system with 5.6KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42720	18041-10000-33120	1417 W PACIFIC COAST HWY	90710	15	033B193    37	7410009040	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.78962	-118.30196	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42721	15041-10000-17779	222 S HOPE ST	90012	14	132A211    90	5151004***	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Issued	07/01/2015 12:00:00 AM	ADDRESS	34.05463	-118.25117	Full plan check for a new restaurant; new load is fed from an existing 3000-amp , 277/480V, 3-phse 4-wire service; Main scope includes 600-A districution panel,  (1) 225 KVA transformer  and and (7) other  panels.T-24 SQ footage is provided by customer, plan checker need to verify the area . Applicant will submit T-24 form before the plan is assigned.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42722	10041-10000-24390	10250 W SANTA MONICA BLVD STE# 185	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IN RETAIL STORE -SONY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42723	17041-10001-32060	2028 E 7TH ST	90021	14	124-5A217 263	5166015002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM			PC Approved	01/10/2018 12:00:00 AM	ADDRESS	34.03441	-118.23125	PC for T24 only for a lost of plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42724	18041-20000-16636	1227 W 253RD ST	90710	15	036B197   404	7413006016	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	33.79484	-118.29814	Plan check for Title 24 only in existing space T.I. Total area: 1,715 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42725	18041-20000-33442	1429 S BEDFORD ST	90035	5	129B169   118	4303011033	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			08/31/2018 12:00:00 AM	08/11/2022 12:00:00 AM		Issued	08/11/2022 12:00:00 AM	ADDRESS	34.05329	-118.38078	Plan check for power and energy for 8 units multi-family 4 story building 800A   Servicein Methane Zone. Total area: 9656 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42726	14041-20000-06556	10750 N MELVIN AVE	91326	12	207B117   128	2708006045	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.26612	-118.55989	PV1 ROOFMOUNTED SYSTEM. TOTAL SYSTEM SIZE 11.4KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42727	13041-10000-10091	1220 N SYCAMORE AVE	90038	4	144B181   286	5532009025	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM			PC Approved	04/18/2013 12:00:00 AM	ADDRESS	34.09318	-118.34267	new construction of 4 unit apartment. multi family dwelling. under 400A new service. pc for energy only for common areas. permit to be issued by pc staff only. total area 4022 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42728	12041-20000-12106	13330 W RIVERSIDE DR	91423	2	168B157   334	2359023003	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.15738	-118.42406	Multipurpose room lighting upgradeEnergy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42729	14041-10000-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			06/17/2014 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	PLANCHECK FOR POWER AND ENERGY FOR  A  NEW 472 Unit Type III  Apt. Building Over Type I Commerciasl Use & Garage Structure. TITLE 24 ENERGY SQFT NOT INCLUDED IN FEES. FEES ARE BASED APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42730	14041-20000-32187	14426 W CLYMER ST	91345	7	207B149   466	2617010003	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.26396	-118.44716	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(21) CANADIAN SOLAR CS6P-250P MODULES(1) SE5000 TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42731	11041-10001-04541	1888 S CENTURY PARK EAST #1030	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM			PC Info Complete	03/11/2011 12:00:00 AM	ADDRESS	34.06104	-118.41402	Tenant Improvement for Spec suite, relocate lights, switches & outlets, all on existing circuits in Suite # 1030. Plan check is for T-24 Energy Calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42732	14041-20000-12654	10351 W SANTA MONICA BLVD 215	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM			PC Approved	05/12/2014 12:00:00 AM	PIN	34.0585564	-118.42324002	PLANCHECK FOR T24 ENERGY. 4 STORY BUILDING .Tenant Improvement in Spec Suite 215. 3526 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42733	16041-10000-35880	3820 E UNION PACIFIC AVE	90023	14	117A229     8	5192001001	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM			Reviewed by Supervisor	11/01/2016 12:00:00 AM	ADDRESS	34.01638	-118.19256	NEW WAREHOUSE. PC FOR POWER AND ENERGY. ALL NEW ELECTRICAL EQUIPMENT. NEW 4000A SERVICE WITH 2000A SWITCHGEAR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42734	17041-10004-00340	5130 N KLUMP AVE	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	09/29/2020 12:00:00 AM	ADDRESS	34.16398	-118.37563	"DELTA ""A"" CHANGES TO APPROVED PLANS FOR ADDING 5 @ ""AIR PUMPS"" RATED 120V, 130W IN UNITS 201, 302, 402, 502 & 602<<<<Full PC for power and energy. New mixed use housing complex -297 dwelling-unit 6 levels of apartment on top of on grade market (core and shell)  above 2 -level of type I construction parking garage.  Scope includes three new services/distribution boards(2500A & 1600A), new panels, new circuits, and new lights for two structures. Total affected area is 266331 Sq. Ft.  B#16010-10000-04268@@@@BUILDING COVERS TWO ADDRESSES:  5101 LANKERSHIM BLVD AND 5130 KLUMP AVE.@@@>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42735	19041-10000-51763	10200 N RATHBURN AVE	91325	12	204B125   225	2731018026	R1-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM			Reviewed by Supervisor	12/26/2019 12:00:00 AM	ADDRESS	34.25625	-118.53255	plan check for PV-1 system. system includes tile pv solar system (192) , (2) inverters and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42736	13041-20000-29098	616 S ARDEN BLVD	90005	4	135B189   891	5505021009	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.0631	-118.32563	PV1 SINGLE FAMILY DWELING. TOTAL SYSTEM SIZE 6.6KW AC USING 2 INVERTERS TRANSFORMERLESS. NONSTANDARD PLAN. 2 STRINGS/INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42737	14041-20001-19099	8501 W PICO BLVD	90035	5	132B173  1242	4332028038	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM			PC Approved	02/19/2015 12:00:00 AM	ADDRESS	34.05355	-118.37643	((2/19/2015)) CHANGES TO AN APPROVED SET OF PLANS.  CHANGES TAGGED DELTA 7 ON THE PLANS.   PLANCHECK FOR T24 ENERGY.  BANK OF AMERICA  ATM LIGHTING. 500 SQFT, EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42738	19041-10000-05765	14430 W POLK ST	91342	7	222B149    45	2505023907	OS-1XL	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.30899	-118.44795	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42739	11041-20000-24825	1233 S NORTON AVE 1-4	90019	10	129B189   811	5081007021	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Apartment			11/18/2011 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.04852	-118.3238	solar system 4.7 kw apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42740	11041-10000-14027	138 E CULVER BLVD	90293	11	096B149   530	4116007069	[Q]C4-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Apartment			07/14/2011 12:00:00 AM			PC Info Complete	12/01/2011 12:00:00 AM	ADDRESS	33.95782	-118.44919	NEW 72 UNIT APARTMENT COMPLEX, HIGH-RISE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42741	15041-20001-42081	5201 W 20TH ST	90016	10	126B177   953	5063001014	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.04046	-118.35441	Expedite feePV1 on multi family dwellings (4 units). Roof mounted installation 3.8kW AC system.(10) Q-Pro BFR-G4 260(10) Power Optimizer SE-P300(1) Inverter SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42742	11041-10000-20762	1990 S BUNDY DR 401	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM			Verifications in Progress	10/18/2011 12:00:00 AM	ADDRESS	34.03419	-118.45559	title 24 and emergency lighting, high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42743	13041-20000-32355	7951 N LARAMIE AVE	91306	3	189B113   537	2107019087	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/26/2013 12:00:00 AM	ADDRESS	34.21523	-118.5731	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 3 STRINGS. 20 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42744	13041-10000-27668	3630 W WATT WAY	90089	9	118-5A201  14	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.02062	-118.28738	INSTALLING NEW FIRE ALARM SYSTEM IN A 4-STORY WITH ROOF & LOWER LEVEL. OCCUPANCY B, A-3 . FULLY-SPRINKLERED SYSTEM. TOTAL BUILDING AREA IS 85,918 SQ FT. WITH 514 DEVICES, 1 CONTROL PANEL, 1 FIRE ALARM PANEL (MODEL NFS2-3030, BY HONEYWELL). EVALUATION OF WORK IS LESS THAN 200K PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42745	13041-10000-27862	1136 W FLORENCE AVE	90044	8	102B197  1211	6019011006	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	33.97444	-118.29512	PV1.  Install 6.25 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE6000A-US.  25 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42746	14041-20001-01961	14620 W SUTTON ST	91403	4	165A149    87	2276028039	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1413.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	04/15/2014 12:00:00 AM	ADDRESS	34.14755	-118.45313	(EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42747	15041-10001-16483	12600 N KENNY DR	91344	12	219B137    32	2609019026	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	34.29895	-118.49856	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.PV1, INSTALL 14.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(43) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-5000 AND PVI-3.8	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42748	14041-20000-33668	6324 N FAIR AVE	91606	2	177B173    48	2336019011	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.18559	-118.37454	pv1central string inverter standard plan system size 6.0kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42749	14041-10000-33725	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	Energy plan check for a high rise office building T.I ( Stair only from top to ground level)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42750	19041-20000-25283	21820 W BURBANK BLVD STE 100	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.17228	-118.6032	T24 PLAN CHECK ONLY FOR EXISTING COMMERCIAL LOW RISE STE 100. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 4,231 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42751	19041-20000-21489	817 E GAGE AVE	90001	9	105B205   884	6007010009	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	11/24/2020 12:00:00 AM		Issued	11/24/2020 12:00:00 AM	ADDRESS	33.98215	-118.26069	Plan check for Service upgrade to 5000A 480/277 Volt 3phase in existing building core and shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42752	15041-10000-18569	523 W 6TH ST 6TH FLOOR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI-24 TO AN (E) 12 STORY BUILDING. SCOPE OF WORK IS IN THE 6TH FLOOR CORRIDOR. PC FOR ENERGY ONLY. TOTAL SQ. FT. 3989.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42753	19041-20000-10459	5028 N WOODLEY AVE	91436	5	168B141    30	2261024012	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.16077	-118.48345	INSTALLATION OF NEW ROOFTOP PV SYSTEM TO EXISTING SFD. SYSTEM SIZE KW 7.625DC/6 KW AC. SCOPE OF WORK INCLUDES (25) MISSION SOLAR PV MODULES WITH P320 OPTIMIZERS AND (1) SE6000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42754	18041-10000-08970	20040 W VENTURA BLVD	91364	3	174B113   598	2166043006	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.171	-118.56999	Plan check for Title 24 only in existing bank Chase, modification in place per Energy Code. Total area: 3,485 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42755	17041-10001-26793	1111 S GRAND AVE	90015	14	127-5A207 332	5139021***	RD1.5-1XL, [Q]R5-4D-O	Central	Central City, San Pedro	Central San Pedro, Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM			PC Approved	06/04/2018 12:00:00 AM	ADDRESS	34.04144	-118.26266	This is plan check only, permit is covered by master #17041-10000-26793.  Revision to approved plan noted as Delta-3, scope includes: revision on single line diagram per field installation (plan check revision is requested by the inspector).<<Power plan check for a new panel connectiong to an existing serving for new EV load for an existing high rise building.  Scope includes new 600A panel, (4) transformer and (8) panels with no load on it.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42756	14041-20000-10123	22412 W SENTAR ROAD	91364	3	168B101   332	2076006031	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Expired	05/24/2016 12:00:00 AM	ADDRESS	34.15813	-118.61526	Roof mounted PV system with syatem size 10.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42757	17041-10000-14936	10250 W SANTA MONICA BLVD UNIT# 1360	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR FIRST TIME TENANT. TI FOR RETAIL STORE (UNIT #1360 TIFFANY & CO.) SCOPE INCLUDES NEW PANELS AND CIRCUITS (277/480 UPSTREAM)TOTAL AFFECTED AREA 4819 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42758	16041-10000-32903	725 S FIGUEROA ST #1830	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR (E) OFFICE SPACE IN A HIGH RISE. TOTAL AREA 715 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42759	18041-10000-09134	16347 W ROYAL HILLS DR	91436	5	159B137    70	2286012027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.13515	-118.48893	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 39 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER. TOTAL SYSTEM SIZE 12.87 KWDC/11.4 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42760	14041-20000-07083	3020 W WILSHIRE BLVD	90010	10	132B197    30	5077013038	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.06165	-118.28725	T24 FOR EXISTING SCHOOL. SCOPE OF WORK ON THE SECOND FLOOR AND IN CLOUDED AREAS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42761	18041-20000-29991	1141 N MANSFIELD AVE Ground-Floor	90038	4	144B181   360	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.09202	-118.34057	Plan check for Title 24 only. Project site is the ground floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 14,344 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42762	14041-10000-12321	3801 W 6TH ST	90020	10	135B193   857	5503021023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.06367	-118.30557	PERMTI TO BE pulled at EPC counter only. Plan check for energy only. 1 story. CHG OF USE FROM RETAIL TO SAME/ ICE CREAM SHOP (21.5' x 65')	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42763	14041-20000-11683	11144 N VIKING AVE	91326	12	210B121   241	2717006016	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.27254	-118.54236	Roof mounted PV system with system size7.54KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42764	15041-10000-37168	9140 S DALTON AVE	90047	8	094-5A195 195	6037009010	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	33.95334	-118.30343	PV1, ROOF SOLAR MOUNTED SYSTEM. (22) MODULES AND (1) INVERTER. TOTAL SIZE: 5KW. (22) KYOCERA #KU2656ZPA(1) ABB #PVI-5000-OUTD-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42765	15041-10001-33963	1037 W M ST	90744	15	033B201   125	7415003023	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM			PC Approved	11/09/2015 12:00:00 AM	ADDRESS	33.78876	-118.27632	Expedited fees for roof mountd solar system. PV1, ROOF SOLAR MOUNTED SYSTEM (21) MODULES AND (1) INVERTER, TOTAL SIZE IS 4.2KW. (21) KYOCERA #KU2656ZPA(1) #PVI-4.2OUTD-S-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42766	19041-20001-50376	230 N BARRINGTON AVE	90049	11	135B145   325	4429024006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM			PC Approved	12/14/2019 12:00:00 AM	ADDRESS	34.06747	-118.47139	PV1 PLAN CHECK FOR NEW ROOF PV AND ESS. SYSTEM SIZE IS 15.925 KW DC/14.37 KW AC CEC. ESS SIZE IS 40.5 KWH. SCOPE OF WORK CONSISTS OF (49) PV MODULES WITH MICROINVERTERS, (3) SUB PANELS, AND (3) 13.5 KWH BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42767	13041-10002-06121	380 WORLD WAY T56	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	NEW PINKBERRY FOR SMALL TENANT SPACE AT THE LAX AIRPORT. NEW TOM BRADLEY TERMINAL. FIRST TIME TENANT, PC FOR POWER AND ENERGY. SPACE T56. ]]]]]]]]]]]]]]]]]]]]] mz 07/04/2013 This is title 24, energy for storage area [[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[(((((((((((((((((((((((((((((  9-12-13  changes to previously approved set, new title 23.  m.zandi  )))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42768	11041-10000-06821	8510 N BALBOA BLVD 1ST FLOOR	91325	12	192B133    87	2689019011	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM			PC Approved	04/06/2011 12:00:00 AM	ADDRESS	34.2251	-118.50158	T.I.  SUITES 175, EXISTING OFFICE BLDG.  TITEL 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42769	11041-20000-27617	6703 N ST CLAIR AVE	91606	2	180B165   215	2322002054	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2011 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.19232	-118.39992	Roof mounted photovoltaic system, SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42770	18041-10000-23703	1031 S BROADWAY	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.04041	-118.2583	PC FOR NEW ELECTRICAL SERVICE IN EXISTING HIGH RISE  BUILDING FOR INTERIOR CORE AND SHELL REMODEL POWER AND ENERGY. SCOPE INCLUDES MAIN SERVICE  AT 4000A 277/480V.SOCPE INCLUDES NEW PANELS, EQUIPMENT AND CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 44,097 SQ.FT  B# 16014-10000-05854	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42771	14041-20001-14051	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.0346	-118.45665	CHANGES TO APPROVED SET OF PLANS. CHANGE CLOUDED DELTA 2 REVISIONS. INCLUDES NEW CIRCUITS AND NEW PANEL. PLAN CHECK AND PERMIT FOR ADDITIONAL ITEMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42772	14041-10000-21562	8847 N LANKERSHIM BLVD	91352	6	195B169   296	2631012060	(F)CM-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.23042	-118.38797	Install a new fire alarm system. 1 panel and 59 fa devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42773	13041-20000-33532	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	Replace and remove existing outdoor light fixtures.  All circuits are existing, no new circuits.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42774	17041-20000-22793	6551 N VAN NUYS BLVD Ste 201	91401	6	180B149   514	2236011023	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.1898	-118.449	Tenant improvement of (E) dentist's office.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42775	17041-10000-14142	600 W WILSHIRE BLVD	90017	14	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.04796	-118.25622	FULL PC FOR COMM. BUILDING NEW HAVC INSTALLTION.SCOPE INCLUDES NEW CHILLERS,, COOLING TOWERS, VFD'S AND MCC ON ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42776	18041-10001-43418	9060 W THRASHER AVE	90069	4	147B169   653	5560007006	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.0982	-118.38828	EXPEDITE PER APPLICANT REQUEST***NEW ROOFTOP SOLAR SYSTEM CONSIST OF 90 MODULES (SLG-M-370) , 90 OPTIMIZERS (SOLAREDGE P400) AND FOUR SINGLEPHASE INVERTERS (SOLAREDGE 7.6KW EACH).  SYSTEM SIZE IS 33.3KWdc and 30.4KWac. SCOPE INCLUDES 200A COMBINER BOX AND 400A SOLAR READY PANEL.***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42777	18041-10000-05101	2210 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.0379	-118.44077	PC for T24 only for restuarant TI. Installing new lights, receptacles and equipment. Total area is 1702sqft. b#17016-10000-33259.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42778	16041-10000-39934	555 N ROSSMORE AVE	90004	4	141B185   977	5523009011	R4-2	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	06/01/2017 12:00:00 AM		Issued	06/01/2017 12:00:00 AM	ADDRESS	34.0805	-118.32738	PC FOR POWER. UPGRADING SERVICE FROM 400A TO 800A 3 PHASE 120/240 V . EXISTING LOAD. METHEANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42779	17041-10001-04264	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	01/12/2024 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC FOR A LOST SET OF PLANS (T-24 FOR CNP SOUTH LOBBY). CHANGE OF CONTRACTOR FROM CUPERTINO ELECTRIC TO DSE ELECTRIC INC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42780	14041-20000-13128	14621 W SHERMAN WAY	91405	6	183B149   799	2219007033	(T)(Q)RAS3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Info Complete	03/10/2015 12:00:00 AM	ADDRESS	34.19948	-118.45171	New 120/208 service and service equipment for (E) 5-story parking structure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42781	17041-10000-20007	12035 W WILSHIRE BLVD	90025	11	126B145    25	4265016043	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			06/14/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.04541	-118.46622	Installation of fire alarm system in new 113,834 sq. ft. apartment building with 5 floors of residential over 3 floors of underground parking.  Total system size = 308 devices + 6 RPS + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42782	18041-10000-00582	10342 N JORDAN AVE	91311	12	204B105   158	2722016014	R1-2	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.25858	-118.60372	PV. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.54KWdc AND 7.6KWac.(26)MODULES-SUNMODULE SWA 290 MONO(26)OPTIMIZERS-P320 SOLAREDGE(1)INVERTER-SOLAREDGE 7.6H	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42783	14041-20000-12992	9119 N CREBS AVE	91324	12	198B121   762	2763021054	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.236	-118.54429	PV1.  Install 8.5 kW roof-mounted PV system, interconnect with main service panel.  33 modules.  (2) Transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42784	18041-10000-02273	660 S FIGUEROA ST PKG LVL 2	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM			Corrections Issued	01/22/2018 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR INSTALLING NEW LIGHT FIXTURES IN PARKING GARAGE ( IN A HIGH RISE) FOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW LIGHTS ONLY IN THE RAMP AREA AND THE FIRST GARHE FLOOR.  TOTAL AFFECTED AREA 14146 SQ.FT.B# 17016-10000-19080	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42785	14041-20000-10891	18714 W VINTAGE ST	91324	12	201B121    63	2729019019	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Expired	05/31/2016 12:00:00 AM	ADDRESS	34.25086	-118.54117	Roof mounted PV sysem with Optimizer and transformerless inverter, system size 3.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42786	13041-10000-34397	1028 S CURSON AVE	90019	4	132B177   859	5085003006	R2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.05666	-118.35734	PV1, install 3 kw DC roof-mounted solar array for a 1-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. (12) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42787	11041-10000-03566	555 E RAMIREZ ST 2ND FL	90012	14	132A217   238	5409021900	PF-1XL	Central	Central City North			2060.20	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.05425	-118.2309	TENANT IMPROVEMENT OF THE 2ND FLOOR PIPERTECH FACILITY FOR LOS ANGELES POLICE DEPARTMENT SCIENTIFIC INVESTIGATION DIVISION  AROUND 38.000 SF ; CHANGE OF USE PORTION OF STORAGE TO OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42788	18041-10000-26024	7829 N BONNER AVE	91352	6	189B173   574	2314008093	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.21294	-118.37386	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.7 KW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42789	17041-10000-37200	152 N CENTRAL AVE	90012	14	130-5A215 384	5161012904	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.05002	-118.23882	replacing outdoor HID WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42790	13041-10001-26297	11343 N ORCAS AVE	91342	7	210B173    39	2529022006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.27585	-118.3684	][][]EXPEDITED PER APPLICANT REQUEST ][][][PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON-STANDARD PLAN. TRANSFORMERLESS SYSTEM, 2TOTAL STRINGS; SYSTEM SIZE IS6.5KW DC WITH (26) MODULES: TRINA #TSM-250PA05.18(1)POWER-ONE #AURORA PVI-5000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42791	14041-10001-20891	3150 W WILSHIRE BLVD # 110	90010	10	132B197    39	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.06163	-118.29086	Change to approved set, mainly adding (3) AC unit on a new Panel-H.  There is minor changes on panel-C by adding and removing some load. All changes on this application apply to delta-4 only.(((Pc for power and energy 2013 T24. First time tenant, wells fargo bank. total areea 3801 sq ft. B# 14016-10000-15374. (see bldg for cra status)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42792	19041-20000-49840	14312 W VICTORY BLVD	91401	6	180B153  1089	2240012010	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.18641	-118.44487	TENANT IMPROVEMENT PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42793	15041-10000-06807	2300 S HILL ST	90007	9	121-5A205  71	5126034020	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.0283	-118.26892	In a warehouse, replacing HID luminaires with LED luminairesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42794	11041-10000-16503	600 W 7TH ST #140 &B116	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	05/25/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	INSTALLATION OF A REDUNDANT 400KW UPS SYSTEM- ONE SUPPLIED FROM THE UTILITY AND THE OTHER FROM EXISTING NON-LEGALLY REQUIRED STANDBY GENERATOR.(VARIANCE FOR DEFERRED APPROVAL OF FIRE ALARM DEVICES SUBMITTED)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42795	19041-20000-41119	5758 N TROOST AVE	91601	2	174B169   322	2339012023	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.17557	-118.3865	PV1. INSTALL 5.280 KW DC / 4.875 KW AC PV SYSTEM WITH (16) MODULES/MICROINVERTERS (ENPHASE IQ7X-96-2-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42796	16041-10000-26940	2177 E 14TH ST	90021	14	120A217    51	5167009013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.02383	-118.23401	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (indoor)1308 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42797	15041-10000-24066	1500 W PACIFIC COAST HWY Bldg G	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 15 unit apartment with garage, . 41 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42798	19041-20000-42766	1020 S WALL ST	90015	14	124-5A211  30	5145019009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM			Reviewed by Supervisor	12/10/2019 12:00:00 AM	ADDRESS	34.03711	-118.25341	Plan check for power and energy 1600A Service 3ph 4W Delta, new HVAC equipments, artifical lighting, general lighting, receptacles and associated load. Per building permit work description: CHANGE OF USE OF WXISTING URM MANUFACTURING BUILDING TO NURSERY WITH ACCESSORY OFFICES. TENANT IMPROVEMETS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42799	16041-10000-12936	2030 W 8TH ST UNIT B	90057	1	132A203   260	5141020017	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.05466	-118.27766	REMODELING OF EISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42800	15041-10000-05564	9039 N SUNLAND BLVD	91352	6	195B173    72	2408005033	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.23351	-118.36728	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3536 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42801	18041-20000-31959	601 S FIGUEROA ST 3re Floor-Rest Room	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 Energy only in existing restroom 3rd floor and receptacle  outlet in corridor.. Total area: 530 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42802	15041-10001-16486	15207 W TYLER ST	91342	7	222B145   419	2604022034	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	34.30156	-118.46416	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.PV1, INSTALL 13.407 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(41) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-3.8 AND PVI-3.8 AND PVI 4.2-OUTD -US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42803	19041-20000-20102	7150 N TAMPA AVE	91335	3	183B117    99	2129001009	R1-1-RIO, RD2-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Issued	09/24/2019 12:00:00 AM	ADDRESS	34.20068	-118.55332	New 4000A and 5000A 480Y/277V 3ph-4w services (MSSA and MSSB) for (2) future buildings.  Electrical permits for building wiring under separate future permits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42804	14041-10000-05246	3150 W WILSHIRE BLVD #106	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	First-time tenant in commercial space (nail & beauty salon occupying 1620 sf) in a mixed-use high-rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42805	17041-20001-35045	555 S MATEO ST Building 2	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM			Corrections Issued	11/13/2017 12:00:00 AM	ADDRESS	34.03943	-118.23302	11/3/2017changes to an approved set of plans.  changes include the addition of tenant spaces 208 and 216 to the initial TI ground level empty tenant spaces.  changes noted delta 4.  total square footage T24 39414.Note: Building application has been generated under 17016-10000-19506	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42806	16041-10000-45027	6039 N CRANER AVE	91606	2	177B173   940	2414004015	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Apartment			12/22/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.18047	-118.36939	Plan check for new appartment 6 units 2 story building.*Service rated at 600A 120/240VTotal area: 8250 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42807	18041-10000-15240	355 S GRAND AVE 18TH FLR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR TITLE 24 ONLY FOR TI FOR EXISTING OFFICE SPACE - TOTAL AFFECTED AREA = 2193 SQ. FT. NOW NEW CIRCUITS BEING ADDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42808	18041-20000-37688	7447 N FALLBROOK AVE	91307	12	186B097   559	2021016021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Issued	10/03/2018 12:00:00 AM	ADDRESS	34.20559	-118.62363	Plan check for a PV1 roof-mounted PV system. System size is 8.505 kWdc/7.6 kWac and consists of (1) inverter, (27) modules, (2) Tesla PowerWalls, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42809	10041-10000-01790	1129 E 5TH ST	90013	9	127-5A215 401	5163025009	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	02/02/2010 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	PIN	34.04171033	-118.23706491	INSTALLATION OF A 9.99 KW PHOTOVOLTAIC SYSTEM. 48 PANELS ON THE ROOF AND 6 PANELS ON THE FACADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42810	19041-20001-04244	9728 W ARBY DR	90210	5	156B157   427	4385014023	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM			Reviewed by Supervisor	02/12/2019 12:00:00 AM	ADDRESS	34.12099	-118.4262	Expedite per applicant request. Plan check for PV roof mounted system and Battery energy storage system, System size: 20.475KW with 63 PV Modules and 2 inverters(7.6KW and 11.4KW) and 3 battery Tesla powerwall 2.0 9.8kWh connected to 600A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42811	17041-10000-21746	704 W 54TH ST	90037	9	108B201   636	5001023010	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Apartment			06/28/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	33.99315	-118.28576	PC FOR 600A SERVICE UPGRADE TO EXISTING APARTMENTS. ALL INTERIOR REMAINS. THIS IS SERVICE AND UNIT PANEL UPGRADE ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42812	12041-20000-31231	118 E 5TH ST	90013	14	129A211   218	5148019001	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM			PC Approved	12/31/2012 12:00:00 AM	ADDRESS	34.04619	-118.24802	Change to lighting on an existing low-rise retail building.  Not a 1st time tenant, load is 80 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42813	13041-20000-32675	22805 W SATICOY ST	91304	12	186B097   195	2014017019	C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.20849	-118.62377	PC FOR EXISTING OFFICES. EXISTING LIGHTING. PERMIT # 13041-20000-32140. PER APPLICANT REQUEST, PC FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42814	15041-10000-37839	454 E COMMERCIAL ST parking	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.05313	-118.23621	new two-stories parking structuresee 15010-10000-01114	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42815	17041-20000-38703	17309 W RAYEN ST	91325	12	195B133   185	2768018006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.23232	-118.51173	addition of (2) tesla power walls.  plan check for power only..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42816	14041-20001-04728	20145 W VIA MEDICI pv1	91326	12	219B113    50	2701041015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.2948	-118.57244	][] expedited per applicant request ][][pv1, roof mounted solar installation, interconnecting with (E) 300A main service PNL. downsizing main breaker for tie-in. ungrounded system, sized @ 5.5 kW DC, with (22) canadian solar #cs6p-250px, (22) OP300 power optimizers, (1) solaredge #SE5000a-us-zb-u	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42817	16041-20000-28139	4470-4474 W ADAMS BLVD	90016	10	123B185   741	5050002018	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.03236	-118.33755	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 6147.PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-30000-08136	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42818	11041-10003-00777	175 S FAIRFAX AVE	90048	5	138B177   750	5511026004	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM			PC Approved	03/20/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	NEW 1 STORY COMMERCIAL BUILDING. PLAN CHECK IS FOR POWER & ENERGY. CORE & SHELL ONLY.((((((( previously approved set has changed , new chanes to be clouded, title 24 changed.  added water heater.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42819	16041-10000-28332	7642 N EL CAPRICE AVE	91605	2	186B165    77	2307008011	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.20986	-118.40105	PV1 Roof mounted installation. Central inverter rated at 3.8 KWac and 14 DC solar modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42820	18041-20000-33456	10509 N DE SOTO AVE	91311	12	207B109   583	2706017020	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.26126	-118.58892	Plan check for PV roof mounted system, system size: 11.68 AC CEC with 44 modules and 1 inverter(11.kW)Fees $70.25 due to California Senate Bill 1222 and Assem Bill 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42821	12041-10000-30783	"12746 W JEFFERSON BLVD ""1"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check power and energy for Building 1. One story retail shell on top of common subterranean parking with Building 2, 3, and 4. Service supplying Building 1 and Building 2. Site located in methane zone. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42822	11041-20000-27709	11001 N SEPULVEDA BLVD	91345	7	210B145   300	2664012031	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1093.00	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	34.2697	-118.4673	Complete Plan Check for Medical office .INTERIOR NON STRUCTURAL TENANT IMPROVEMENT TO PORTION OF 2ND STORY KAISER MEDICAL CLINIC BUILDING ( APPROX 1183.5 SF) :  NEW NON BEARING PARTITION WALLS TO CREATE EXAM ROOMS AND OFFICES.Fire Alarm  system is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42823	13041-10001-32419	1301 N LUCILE AVE	90026	13	144A201   391	5427013031	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.08724	-118.28141	Expedited RSES plan check per applicant request.(((PV1, Install 2.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 9 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42824	19041-20000-50122	9400 N BURNET AVE UNIT 103	91343	7	198B145   103	2656021***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	PIN	34.2413442	-118.46253399	PV1.  Install 6.6 kW DC roof mounted grid tied PV system.  (20) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42825	15041-10001-27151	22516 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	33.82154	-118.30136	Install rooftop solar system 2.15 kW AC system. permit under 15041-90000-27151	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42826	19041-10000-27494	22400 S HALLDALE AVE	90501	15	048B193   809	7347004901	OS-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	33.82315	-118.30138	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42827	18041-10000-12996	1003 E 4TH PL	90013	14	127-5A217  55	5163018002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.04219	-118.23383	Install New Fire Alarm system on a 6-story parking + 2-story future office. (1) FACP, (3) Power supply, (100) FA devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42828	13041-10000-17895	17631 W VANOWEN ST	91406	6	183B129  1030	2229001017	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	03/15/2014 12:00:00 AM	ADDRESS	34.19401	-118.51769	pc for power and energy. 1 story. NEW DISTRIBUTION, LIGHTING & POWER FOR TI. type B occupancy per applicant.CHANGE OF USE FROM GROCERY STORE (MARKET). SELECTIVE DEMOLITION OF EXISTING INTERIOR WALLS, CONCRETE FLOOR, DOORS AND WINDOWS, TO THEN CONSTRUCT NEW PLASMA COLLECTION FACILITY INCLUDING INTERIOR IMPROVEMENTS, ROOF STRUCTURAL UPGRADES FOR HVAC WORK, NEW STRUCTURAL UPGRADE. RECLASSIFY BLUDING FROM TYPE III A TO TYPE III B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42829	19041-20000-40719	1251 S WEST BLVD	90019	10	129B185   668	5083031002	R3-1	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Apartment			10/08/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	01/25/2024 12:00:00 AM	ADDRESS	34.0501	-118.33335	POWER & ENERGY PC FOR A NEW 1000Amp  120/208 V 3 Phase 4 Wire SERVICE.TOTAL AFFECTED AREA: 10024 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42830	11041-20000-19447	1303 S WELLESLEY AVE	90025	11	126B145   592	4267033023	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	34.04118	-118.46773	NEW FIRE ALARM SYSTEM FOR 5-STORY APARTMENT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42831	12041-10001-06520	6333 W 3RD ST STALL#112	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			PC Approved	05/23/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	Changes to approved title 24 unde 12041-10000-06520. Plan check for energy, no changes to emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42832	19041-10000-24166	2911 W EXPOSITION PL Units 1-5	90018	10	117B185  1312	5044011026	CM-1-SP, RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.02047	-118.32807	NEW FIRE ALARM SYSTEM FOR WATER FLOW MONITERING. SYSTEM CONSIST OF 1 FIRE ALARM PANEL, 1 COMMUNICATOR AND 9 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42833	13041-10000-33755	541 S SPRING ST STE # 101	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.04657	-118.2507	PLANCHECK FOR T24 ENERGY. T.I. - CHANGE OF USE FROM EX TWO RETAIL TENANT SPACES (#104 & 105) TO ONE RESTAURANT (#104) - 1,048SF, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42834	16041-10002-43848	7374 1/2 W MELROSE AVE	90046	5	141B181   609	5526020026	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM			PC Info Complete	01/18/2017 12:00:00 AM	ADDRESS	34.08344	-118.35069	TITLE 24 FOR EXISTING LOW-RISE COMMERCIAL BUILDING(HAIR SALON). TOTAL 862 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42835	13041-10000-18783	1042 W PRINCETON DR	90292	11	105B149   499	4229003049	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	33.98606	-118.44621	COMMERCIAL TI, TITLE-24 PC ONLY. ASSOCIATED BUILDING PERMIT: TENANT IMPROVEMENT OF EXISTING MANUFACTURING SPACE TO CREATE NEW SEPARATE UNITS:  UNIT B OF 2,936 S.F. AND UNIT C OF 3,831 S.F.  NO CHANGE OF USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42836	14041-20003-31034	5048 N SHIRLEY AVE	91356	3	171B117   452	2175033007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	ADDRESS	34.16233	-118.55683	07-27-2015 Plan check for change to approved set of plans. Derate the main panel from 375A Breaker to 350A Breaker. [[[[[PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 19.6 DC.(60) SUNPOWER 327W(1) SMA SB8000TL(1) SMA SB10000TL]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42837	16041-20000-39808	7120 N HAYVENHURST AVE	91406	6	183B137    95	2224017027	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	34.1997	-118.49221	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING. 58,000 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42838	17041-10000-25457	6543 N CORBIN AVE	91367	3	180B117   546	2134024019	A1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Issued	07/27/2017 12:00:00 AM	ADDRESS	34.18939	-118.56242	PC for T24 for outdoor lighting. replace HID fixturs with new LED fixtures. Total area of 56400sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42839	10041-10000-08861	121 N LA CIENEGA BLVD #835	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.07484	-118.37674	T.I. to existing high rise building in 8th floor (EAST and WEST) and in 9th floor.  Install new panels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42840	17041-10000-04616	20065 W RINALDI ST BLDG A4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.27548	-118.57184	PC FOR POWER AND ENERGY. NEW BUILDING A4 - 2 STORY COMMERCIAL SHELL ONLY , SERVICE SIZE 1600A 277/480 V, TOTAL AREA 11328 SQ FT.Building app# 16010-10000-06137	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42841	19041-20000-28549	1620 W 265TH ST	90710	15	030B193   101	7411010028	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	33.78108	-118.30565	Plan check for PV roof mounted system, PV system size: 4.95KW with 15 PV Modules and 15 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42842	17041-10000-15308	10250 W SANTA MONICA BLVD FC-3	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Pc for take out restaurant ""Asian Box"" in food court unit FC3. first time TI. pc for power and energy"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42843	11041-10000-22270	5250 N LANKERSHIM BLVD 7TH FLOOR	91601	4	171B173  1421	2350018090	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	10/20/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	34.16668	-118.37545	T.I. FOR OFFICE ON 7TH FLOOR:  (N) INTERIOR NON-BEARING PARTITIONS TO SUBDIVIDE PORTION OF (E) OFFICE TO SEPARATE OFFICE SPACE.  INCLUDES MILLWORK, CEILING SYSTEMS, AND FINISHES.  PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42844	11041-10000-27334	105 W CENTURY BLVD BLDG 2	90003	8	091-5A203  82	6053020029	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	33.94571	-118.27437	1-STORY RETAIL BUILDING #1 (2 TENANT SPACES). CORE AND SHELL ONLY.  TI UNDER SEPARATE PERMIT.  (BLDG # 1 IS UNDER PCIS # 11041-10000-27330)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42845	17041-20000-38405	6255 W SUNSET BLVD 6th  flr	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.09815	-118.32564	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42846	19041-20001-15155	5808 W SUNSET BLVD LEVEL 11	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.09782	-118.31646	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. CHANGES TO T24 SHEETS, LIGHTING FLOOR PLAN, LIGHT FIXTURE SCHEDULE, SHEET INDEX, AND ADDITION OF PHOTOMETRICS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42847	14041-10000-28057	2200 W OLYMPIC BLVD	90006	1	130-5A201 159	5136014025	C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.05198	-118.28133	PLANCHECK FOR ENERGY ONLY. (PHASE III RENOVATION) RENOVATE EXISTING MOTEL 31 UNITS IN BUILDING D. UPGRADE 1 GUEST ROOM INTO ACCESSIBLE ROOM. REMODEL STAIRS. TOTAL  AREA 10300 SQ FT.B# 14016-10000-19705.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42848	15041-10000-05523	6800 N OWENSMOUTH AVE UNIT 350	91303	3	183B105   949	2138006044	P-1VL-RIO, [Q]CR-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM			PC Info Complete	02/25/2015 12:00:00 AM	ADDRESS	34.19413	-118.60138	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FOOTAGE 1442	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42849	10041-10000-18187	729 E TEMPLE ST	90012	14	130-5A217 361	5173015006	M3-1	Central	Central City North	Historic Cultural		2060.30	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Finaled	09/30/2010 12:00:00 AM	ADDRESS	34.05023	-118.23261	T-24 lighting and emergency lighting plan check for remodeled office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42850	17041-20000-10940	13075 W VICTORY BLVD 101	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Issued	04/05/2017 12:00:00 AM	ADDRESS	34.18684	-118.41708	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR EXISTING RESTAURANT. 2077 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42851	18041-20000-14092	7401 N SHOUP AVE	91307	12	186B101   532	2022019023	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.20486	-118.61489	ti to an existing school.  adding new lighting new controls to existing panels.  plan check for energy indor/outdoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42852	16041-20000-40998	10251 ANGEL LANE	91331	7	204B165   435	2537004045	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25680532	-118.40466918	pv1install roof mounted pv system sized 3.6kw interconnected with msp.  standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42853	18041-20000-11798	725 S FIGUEROA ST SUITE 2200	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42854	17041-10000-28644	3940 S HILL ST	90037	9	115-5A203  57	5122045019	[T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Issued	11/06/2017 12:00:00 AM	ADDRESS	34.01187	-118.27963	Plan check for power only, service upgrade from 400A to 600A on an (E) 8 units apartment.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42855	16041-10000-38601	3016 E WINTER ST	90063	14	129A227   280	5178008022	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.04707	-118.19744	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR LIGHTING). TOTAL AREA 7760 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42856	11041-10000-07014	13245 W RIVERSIDE DR	91423	5	168B157   316	2358014027	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Public Safety Only			04/08/2011 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.15778	-118.42187	New fire alarm system for a commercial Bldg. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42857	16041-20000-45435	3939 S CRENSHAW BLVD C	90008	10	117B185  1137	5032002057	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.01358	-118.33646	ti to an existing single commercial building.  adding new lighting new ontols to new panels and associated equipment.  total connected load < 400amps.  plan check for energy only.  total square footage 1113.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42858	19041-10000-39331	3868 N GLENALBYN DR	90065	1	145-5A223 340	5451012015	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.09166	-118.21338	PV1. NEW ROOFTOP SOLAR SYSTEM WITH BATTERY BACKUP. SYSTEM CONSIST OF 16 MODULES (FREEVOLT SW 300), OPTIMIZERS (PIKA ENERGY S2500), 1 CENTRAL INVERTER (PIKA X7602) WITH PIKA ENERGY HARBOR PLUS BATTERY. SYSTEM SIZE IS 4.8KWDC AND 8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42859	18041-20000-08394	14421 W VAN NUYS BLVD	91331	6	201B149   285	2647028015	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.24828	-118.44681	permit fee $0.00 by state senate bill no.1222pv2install roof mounted pv system sized 156kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42860	16041-20000-07172	7030 N JAMIESON AVE	91335	3	183B129   427	2121029016	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.19853	-118.52142	Plan check for a PV1 roof-mounted PV system. System size is 4.3 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42861	14041-10000-18111	1401 N AVENUE 47	90041	1	156A221   285	5474028005	RD3-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	PIN	34.12056278	-118.21444161	PV1 5.355KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(21)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42862	17041-20001-08297	9171 N GAZETTE AVE	91311	12	198B109   142	2748036024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM			PC Approved	04/13/2017 12:00:00 AM	ADDRESS	34.23761	-118.58729	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 36 kWac and consists of (3) inverters, (126) modules, and (1) solar load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42863	14041-10001-21358	2215 E ALCAZAR ST	90033	14	135A225     6	5202003019	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM			Corrections Issued	01/19/2017 12:00:00 AM	ADDRESS	34.06357	-118.20153	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 10 AND UNDER. REVISIONS TO AMENITY AREA. REVISED LIGHTING AND POWER LOADS. PROVIDED UPDATED T24 AND PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42864	14041-20000-01893	4056 S MARCASEL AVE	90066	11	111B157   371	4233010006	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.00154	-118.42331	New UNGROUNDED rooftop PV system on an existing single family dwelling.  Existing 400 AMP Service size.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42865	18041-20000-25400	22 N OAKMONT DR	90049	11	135B137   135	4426034031	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM			PC Approved	05/20/2020 12:00:00 AM	ADDRESS	34.06893	-118.48983	600A 240/120V 1ph-3w service, distribution, power, and lighting for new single family dwelling.  Plan check for power only.  Note: Building permit has been issued under 16010-30000-05051. Electrical permit fees have been paid for under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42866	19041-10000-04853	901 N SYCAMORE AVE	90036	4	132B181   487	5084004010	R2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	PIN	34.05872439	-118.34452079	Plan check for fire alarm system with (1) fire alarm panel, (4) power supplies and (67) fire alarm devices located in a 2-story commerical building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42867	12041-10000-03173	11833 N ANDASOL AVE	91344	12	216B129   339	2601041042	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.28614	-118.51485	Plan check for new roof mounted 3.45KW Enphase Microinverter photovoltaic system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42868	19041-20000-42155	10558 W LINDBROOK DR	90024	5	135B153   495	4360018010	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM			Reviewed by Supervisor	10/31/2019 12:00:00 AM	ADDRESS	34.06345	-118.43374	Plan check for PV roof mounted and Energy Storage system, PV system size: 7.26KW DC, 7.6KW AC with 22 PV Moduels and 1 inverter(7.6KW) and Sonnen Eco  battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42869	18041-10000-33610	10250 W SANTA MONICA BLVD #2755	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT - Teanant improvement to existing retail space within Westfield Century City mall. Scope include new interior non-bearing partition, millworks, ceilings and finishes. - TOTAL AFFECTED AREA = 1637 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42870	15041-10000-11996	100 WORLD WAY TERM 6	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	at lax, installation of illuminated  numeral signs to identify the terminalsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42871	16041-30000-08448	13630 W SATICOY ST	91402	6	186B157   140	2214025004	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.20928	-118.42941	Plan check for PV system on conbination of roof mount and new carport in existing roof. Total system size: 302.2kW with 828 modules and 6 inverters(STP24000TL-US) and 2 inverters(STP2000TL-US) connect to supply side tap.     low fees due to senate bill1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42872	13041-10000-32111	22102 W CLARENDON ST	91367	3	174B101   484	2169026084	CR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.16947	-118.60824	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING( NO RETAIL) NO CHANGE OF USE. COMBINE 5 SEPARATE TENANT SPACES TO ONE TENANT SPACE. (APPLICANT NEEDS TO PAY FOR ADDITIONAL 13 BRANCH CKTS, DID NOT PAY DURING SUBMITTAL DUE TO PRE CUT CHECK)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42873	19041-10000-32277	12172 N TRUMAN AVE	91342	7	216B149   114	2611009012	C2-2D-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.29157	-118.44931	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42874	18041-10000-38858	401 E 7TH ST	90014	14	127-5A211 276	5148024026	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.04196	-118.24829	NOTE: FEES ARE $0 DUE TO AB 1414.NEW COMMERCIAL ROOFTOP SOLAR SYSTEM CONSIST OF 124 MODULES (HANSOL HS340) AND 64 POWER OPTIMIZERS (P730) WITH 3 CENTRAL INVERTERS (2 SOLAR EDGE SE14.4KUS + 1*SOLAR EDGE SE9KUS). SCOPE INCLUDES NEW 200A LOAD CENTER.  SYSTEM SIZE IS 46.72KWdc and 37.8KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42875	13041-20000-32990	15420 W COBALT ST	91342	7	222B145    42	2501006031	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.3084	-118.46795	Change to lighting using all existing circuits in an existing low-rise office building.  PLAN CHECK ONLY for Energy.  Emergency lighting NOT required per the Architect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42876	12041-20000-01176	808 S SPRING ST	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM	01/18/2012 12:00:00 AM		Permit Closed	04/30/2012 12:00:00 AM	ADDRESS	34.04272	-118.25371	temp.power 800 Amps	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42877	14041-20000-27783	13784 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.30953	-118.43339	Plan check for power and energy. New electrical work in existing 2nd floor fitness center. 12,450sqft. Service equipment and main distribution board MS are existing (all other electrical work is new).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42878	15041-20000-19305	17833 W SIMONDS ST	91344	12	213B129   369	2711017008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.27653	-118.52272	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 9.2KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42879	16041-10001-17639	1729 S LIVONIA AVE	90035	5	129B169  1013	4305023022	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	06/07/2016 12:00:00 AM	ADDRESS	34.04811	-118.38692	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.84KWdc / 11.4KWac.(37)MODULES-SOLARWORLD SW320 XL MONO(37)OPTIMIZERS-SOLAREDGE P400 (1)INVERTER-SOLAREDGE SE11400A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42880	16041-10001-25310	2884 S MCCONNELL DR	90064	5	126B165   939	4308016014	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM			PC Approved	09/06/2016 12:00:00 AM	ADDRESS	34.03876	-118.40178	EXPEDITED RSES PLAN CHCK PER APPLICANT REQUEST.<<<PV1, NEW 5.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, WITH P6 V BATTERY BACK UP.(18) MODULES: SUNIVA OPT280-60-4-1B0(1) INVETER: MAGNUM MS4024PAE>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42881	15041-10000-32385	700 N ALAMEDA ST	90012	14	132A215   180	5409023930	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			PC Info Complete	05/18/2016 12:00:00 AM	ADDRESS	34.05488	-118.23748	Energy plan check for under ground 2-parking level. scope includes new light and (1) equipment;  no new circuits added; total area 308,300-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42882	19041-20000-41545	20552 W BLUEBIRD CT	91326	12	219B109   498	2701103048	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.29704	-118.58182	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.725 KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42883	11041-10000-15308	1519 S BUNDY DR	90025	11	126B145   787	4263038032	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.03993	-118.46282	T.I.  Existing 7-11.  Replacing 28 light fixtures, using the existing branch circuits, in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42884	17041-20002-39694	5959 N TOPANGA CANYON BLVD	91367	3	177B101   228	2146006012	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	34.17827	-118.60529	Note: $0.00 permit fee due to CA Senate Bill 122206-19-2018 Changes to an approved set of plan, changes include change conductor size from inverter to load center. Changes apply to clouded delta only. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42885	19041-10000-18025	6316 N TOPANGA CANYON BLVD 1120-1125	91367	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.18578	-118.60514	PERMIT FEES PAID UNDER 19041-10000-15355Energy plan check for an amusement enterprise located in the mall. Scope includes new lighting and equipment with a total area of 4940-SQ FTBld# 19016-10000-00916	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42886	17041-10000-19895	11115 W MCCORMICK ST	91601	2	171B173   389	2350018915	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	05/26/2020 12:00:00 AM	ADDRESS	34.16605	-118.373	PLAN CHECK FOR POWER AND ENERGY FOR NEW  4 STORY 14 UNIT (4 Typical)  MIXED USE APPARTMENT - SCOPE INCLUDES (N) 1200A, 120/240V, 3Ph, 4W DISTRIBUTION BOARD . TOTAL AFFECTED AREA = 16561 SQ. FT.((B# 16010-20000-03155))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42887	14041-20000-21680	12737 W VENTURA BLVD F	91604	2	165B161   990	2375021018	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.14491	-118.4107	Plan check for energy only on a T.I office. total 643 SQ feet.PERMIT IS UNDER SEPERATED APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42888	18041-20001-17484	9466 N REMICK AVE	91331	7	198B161    80	2626016064	RA-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.24157	-118.41666	Expedited plan check fee.(((PV2.  Install 22.75 kW DC roof mounted grid tied PV system.  (70) modules regulated by power optimizers with (2) 14.4 kW AC rated string inverters.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42889	14041-10000-09905	333 S AVENUE 17	90031	1	136-5A219 165	5447028006	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.06827	-118.2219	Title 24.  Remove HID light fixtures and replace with new fluorescent fixtures.Total area = 3788 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42890	19041-20001-04514	5206 W LOS BONITOS WAY	90027	4	151-5A195  94	5588035029	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Issued	05/09/2019 12:00:00 AM	ADDRESS	34.10996	-118.30337	Revisions to online permit plan printout.  Module count adjusted to (28) total.  All other details unchanged.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42891	14041-10000-03276	1521 S LOS ANGELES ST	90015	14	124-5A207 400	5133013010	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.03346	-118.26151	PLAN CHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 360 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42892	15041-10000-12047	6250 N TOPANGA CANYON BLVD 1515	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Change of use from retail to salon.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42893	16041-10000-06448	10955 W PEORIA ST	91352	7	201B173   311	2538014015	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Expired	03/26/2018 12:00:00 AM	ADDRESS	34.24668	-118.36936	PV1, ROOF MOUNTED SYSTEM USING CENTRAL INVERTERS. NEW 3.0KW INVERTER ADDING TO AN EXISTING 3.0 KW INVERTER. (10) MODULES AND (1) 3.0KW INVERTER. NEW TOTAL SIZE OF SYSTEM IS 6.0KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42894	18041-10000-15166	10720 S WILMINGTON AVE	90059	9	088-5A215  21	6068001040	C2-1VL	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	33.93844	-118.2388	0$ permit fees due to senate bill 1222 , ab 1414PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 51.84 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42895	19041-10000-03149	355 S GRAND AVE # 2825	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.05191	-118.2525	pc t-24 only. scope of work 3400sqft.INTERIOR TENANT IMPROVMENT TO (E) OFFICE SUIE #2825, NEW PARTITIONS, CEILINGS AND FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42896	19041-10000-53126	1329 N NEW HAMPSHIRE AVE	90027	13	147B197  1003	5543016010	R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	04/01/2021 12:00:00 AM		Permit Finaled	07/28/2023 12:00:00 AM	ADDRESS	34.09641	-118.29309	PLAN CHECK FOR A NEW APARTMENT BUILDING. SCOPE INCLUDES (2) 2000A SERVICE, 120/208V. SCOPE OF WORK INCLUDES (92) SUB PANELS, EQUIPMENT AND MOTORS. TOTAL AFFECTED AREA IS 57,000 SQ FT. PER BUILDING DESCRIPTION: ************NEW 7-STORY, TYPE IA/IIIA, 92-UNIT, APARTMENT BUILDING OVER 2 LEVEL, TYPE IA, SUBTERRANEAN PARKING GARAGE. TOC TIER 3/4 PROJECT WITH 11 ELI RESTRICTED UNITS. THE FIRST TWO STORIES ARE TYPE IA WITH 25 UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42897	19041-10001-36511	233 S ANITA AVE	90049	11	129B141    57	4405030004	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.05351	-118.48225	EXPEDITE FEESPV1, NEW ROOFTOP MPUNTED SYSTEM, SYSTEM SIZE IS 11.55 KWdc/11.2 KWac. SCOPE OF WORK IS 35 MODULES (PANASONIC VBHN330SA17E) WITH MICRO INVERTERS (ENPHASE IQ7X-96-2-US), LEADING TO A ENPHASE COMBINER BOX, LEADING TO A MAIN BREAKER DERATE (PERMIT  HAS BEEN PULLED FOR THE BREAKER DERATE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42898	16041-10000-08367	321 N LARCHMONT BLVD STE 1023	90004	4	138B189   360	5523020038	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM			PC Approved	03/09/2016 12:00:00 AM	ADDRESS	34.07682	-118.32384	"TI TO SUITE 1023 - PC FOR T24 ENERGY ONLY""Comply with department order effective date 4/24/2015.  Permit will expire 30 days from issuance date."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42899	18041-20000-12528	5555 W MELROSE AVE Stage 5	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for power and energy service replacement for 2500A and 750KVA Transformer to new equipment and reconfigured location of service equipment. Exinsting load to remain Total area: 840 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42900	19041-20000-03644	2770 N ROSCOMARE ROAD	90077	5	156B145    80	4378014001	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.12538	-118.46527	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (3) battery back-up units to an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42901	15041-10000-20934	6849 N COSTELLO AVE	91405	2	183B153   933	2216015021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.1955	-118.43793	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42902	16041-10000-17795	687 S HOBART BLVD	90005	10	132B193   184	5093006035	(T)(Q)C2-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.0605	-118.30557	Installation of a new fire installation system. (240) FA devices. (3) Control panel (1) communucation, (1) fire alarm panels. conduit only variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42903	17041-20000-21345	11301 W PICO BLVD	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM			PC Approved	06/23/2017 12:00:00 AM	ADDRESS	34.03517	-118.43924	ti to an existing commercial building.  adding new lighting new controls to nmezzanine in existig panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42904	14041-20001-05195	5816 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	33.97382	-118.41957	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42905	15041-20000-29001	9717 N LASAINE AVE	91325	12	201B129   249	2755015017	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.2474	-118.51295	PV1 system. Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). (36) 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42906	14041-20001-29272	10908 W MESETA DR	91040	7	204B173   192	2542031009	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.25499	-118.3678	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM. USES COMBINER BOX WITH 4 STRINGS. TOTAL OF 40 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42907	18041-10000-48966	1200 S LA BREA AVE	90019	10	129B181    92	5084027034	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.05319	-118.34347	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42908	11041-20000-21224	3759 S BARRY AVE	90066	11	114B157   858	4234016015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.00867	-118.42637	pv system 2.81 kw micro invereter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42909	16041-20000-31883	12347 N ARAGON WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29511	-118.45483	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42910	16041-20001-23265	6431 N INDEPENDENCE AVE	91367	3	180B109   592	2149003039	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	34.18737	-118.59079	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 75 kWac and consists of (5) inverters, (255) modules, (5) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42911	17041-20000-39328	17213 W VENTURA BLVD UNIT B	91316	5	171B133   679	2258012022	[Q]C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.16078	-118.50802	TI to (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42912	19041-10000-33111	8201-8203 W 3RD ST	90048	5	138B173   840	5511019036	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.07259	-118.36814	T-24 PLAN CHECK FOR  NEW STAND ALONE RESTAURANT. NEW 400A SERVICE, EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1,985 SQ.FTPOWER PLAN CHECK MAY BE REQUIRED SUBJECT TO FIELD INSPECTIONB#14010-10000-01124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42913	17041-20002-05715	14006 W RIVERSIDE DR STE 245A	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM			PC Approved	06/28/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	6/28/17changes to an approved set of plans.  changes include different light fixtures.  this is plan check only.   (((Plan check for Title 24 only in existing space T.I. retail. Total area: 3,609 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42914	17041-10001-08953	5800 W SUNSET BLVD 1ST FLR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	DELTA 4 REVISIONS TO APPROVED SET OF PLANS-PANEL KA RATED 100A DOWN FROM 225A AND LOADS DECREASED; CU-1 FEEDE 2REMOVED; CU-1 FEED 1 AND WH-1 RATING IS REDUCED, PLANS ARE UPDATED WITH THE CHANGES((((((((FULL PC FOR POWER AND ENERGY. CHANGE OF USE OF A PORTION AT 1ST FLOOR FROM OFFICE TO RESTAURANT. SCOPE INCLUDES ONE NEW 5KV FEEDER, NEW 400A DISTRIBUTION BOARDS, NEW TRANSFORMERS, NEW PANELS, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 3368 SQ. FT. B#17016-10000-04839	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42915	12041-10000-08100	2222 W OLYMPIC BLVD 2ND  FLR	90006	1	130-5A201 149	5136014023	[T][Q]C2-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.05203	-118.28191	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR  INTERIOR OFFICE TI 2ND FLOOR. PERMIT FOR NEW BRANCH CIRCUITS, EXISTING PANEL. LOADS LESS THAN 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42916	13041-10000-21837	3421-3425 E EMERY ST	90023	14	117A225   158	5192014012	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			PC Approved	08/15/2013 12:00:00 AM	ADDRESS	34.01538	-118.20603	Title 24 plan check only for manufacturing building.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42917	14041-10001-05196	5031 W LEMON GROVE AVE	90029	13	141B193    66	5535024001	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.08636	-118.30617	Expedited plan check per applicant request.  (((PV1.  Install 3.75 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US-ZB-U.  15 modules: Canadian Solar CS6P-250PX.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42918	14041-10001-23083	6804 N DE SOTO AVE	91306	3	183B109   822	2137012027	(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM			PC Approved	12/22/2014 12:00:00 AM	PIN	34.19447423	-118.58747412	Change to approved set by removing some declaration notes and reducing AIC rating for some panels. all changes are under Delta-A only.(((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT.  NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD >400 AMPS.BUILDING P# 14016-30000-10638)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42919	15041-10000-17476	1167 S HOOVER ST	90006	1	129A201    16	5076014013	R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.04967	-118.28446	PC FOR POWER AND ENERGY. NEW MIXED USED APARTMENT BUILDING. 35 UNITS 3 STORY. TOTAL AREA 19545 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42920	16041-10002-19933	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM			PC Approved	03/15/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC FOR ENERGY FOR FACILITY IMPROVEMENT FOR TERMINAL 3 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUSING OPERATION, OFFICE RENOVATION, AND IMPROVED FINISHES AND MILLWORKTHE APPLICATION 16041-10000-11825 IS RELATED TO CONNECTED LOAD OTHER THAN THE SCOPE OF THE WORK FOR THIS PROJECT.BUILDING APPLICATION IS 16016-1000-11866. TOTAL AREA 4991 SQ FT.(((((   3-9-2017   M.Z   addtion of two fixturers in the vestibule area  and emergency lighting)))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42921	14041-20001-05719	17513 W BULLOCK ST	91316	5	177B129   449	2254033001	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.17978	-118.51463	Fee for expedite only*****Roof mounted PV system with 5.25KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42922	16041-20001-44588	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.23342	-118.3809	[[4/6/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES ARE CLOUDED. CHANGING SOME FEEDER SIZES AND CONDUIT SIZES ]]]PC FOR POWER. INSTALLATION OF COMPRESSED NATURAL GAS COMPRESSION AND FUELING DISTRIBUTION SYSTEM. SERVICE UPGRADE 3000A. HAZARDOUS AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42923	15041-10001-07526	811 W 7TH ST	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.04908	-118.25911	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.  CHANGES TO REFLECT EXISTING FIELD CONDITIONS.  PLAN CHECK FOR POWER ONLY.  Replacement of electrical distribution equipment in (E) commercial highrise building.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42924	14041-20000-05897	4573 N WILLIS AVE	91403	4	168A149   155	2264017037	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Apartment			03/04/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.15404	-118.45544	Roof mounted PV system with 18.9KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42925	14041-10001-07484	6321 W HOLLYWOOD BLVD	90028	13	148-5A187 150	5546004013	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.10178	-118.32754	PLANCHECK FOR POWER AND ENERGY. Changes made: addition of new service 800A instead of using (E) 400A. (E) 400A switchboard is used as distribution board. Addition of 150kva transformer.  Relocated loads. Panel NN2 and MM2 are new.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42926	17041-30000-45031	21021 W VENTURA BLVD	91364	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.16688	-118.59113	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from office to beauty salon/tenant improvement. Total lighting area = 6,815 sq. ft.Note: Building application has been generated under 17016-20000-36905	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42927	17041-20000-34734	13113 W VAN NUYS BLVD unit d	91331	7	210B161   744	2535018026	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.26875	-118.41881	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42928	14041-20000-28099	9778 N STANWIN AVE	91331	6	201B153   395	2645017017	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.24821	-118.43391	PV1.  Install 4.25 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42929	13041-20000-09837	7914 S RAMSGATE AVE	90045	11	099B169   739	4105024015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2013 12:00:00 AM	05/06/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	33.96709	-118.38108	New PV system for the rooftop of an existing single family residence.  Enphase Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42930	18041-10000-20708	9411 N WINNETKA AVE	91311	12	198B113    92	2748038028	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Issued	06/05/2018 12:00:00 AM	ADDRESS	34.24139	-118.57126	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42931	10041-20000-19202	1908 N NORTH BROADWAY	90031	1	138A221   216	5447024006	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM			PC Info Complete	12/07/2010 12:00:00 AM	ADDRESS	34.07211	-118.22093	Plan check power and energy for new car wash. Car wash equipment buy others.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42932	15041-10000-36889	5814 S 2ND AVE	90043	8	108B189  1450	4005025010	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	33.98858	-118.31948	PV1, ROOF MOUNTED SOLAR SYSTE, TOTAL SIZE 3KW. (11) MODULES AND (1) INVERTER. (11)KYOCERA #KU2656ZPA(1) ABB# PV1-3.00-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42933	15041-10000-29773	1433 E WALNUT ST	90011	9	120A213   308	5129006031	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.02193	-118.24752	PC at counter for new FA system to an existing commercial 5 story bldg. (offices/wherehouse) (1) FA panel, (1) Communication panel, (5) Control Panels, (119) FA devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42934	10041-20003-22501	19600 W PLUMMER ST CABANA-BLDG	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.2426	-118.5602	"Most recent version of modified plan fot the new CABANA"" BUILDING (SEPERATE POOL HOUSE AND REC ROOM FOR AN APARTMENT BUILDING THAT WAS APPROVED UNDER 10041-10000-22501).  PLAN CHECK IS FOR POWER & ENERGY.   The permit is for all previous vetsions of the plan.  Not permit is to be issued for 10041-10001-22501."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42935	17041-20000-45970	360 E 2ND ST	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL. 2533 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42936	09041-10015-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Closed	01/03/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans (autofiles) for the north  and south concourses at BRADLEY WEST GATES ; Reference GDN-121;-193;193R1  AND -200.INCLUDE MEDIA FEATURES , CLUSTER SEATING AND TELCOM ROOMS POWER DISTRIBUTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42937	11041-20000-02801	6600 N TOPANGA CANYON BLVD #2048	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	05/26/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42938	19041-10000-09217	11150 W SANTA MONICA BLVD	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	PC  for new FireAlarm system. scope is a 16 story building. scope includes 3-FACP and  580 Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42939	13041-20000-34049	7250 N HAZELTINE AVE	91405	2	186B153   714	2216002058	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Apartment			12/06/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Expired	04/28/2015 12:00:00 AM	ADDRESS	34.20287	-118.43981	PV2 MICROINVERTER SYSTEM FOR APARTMENT. TOATL SYSTEM SIZE 30KWAC. 120 MODULES AND MICROINVERTERS. Zero fees due to Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42940	12041-10003-12382	221 S GRAND AVE	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.05419	-118.2505	CHANGES TO APPROVED SET, PLAN CHECK ONLY. DETLA 7 CHANGES.  ADDING 1 POWER SUPPLY BPS10A, 3 SIGA CT2, 1 SIGA CR AND REMOVING 1 SIGA-278 PULL STATION AND 2 SIGA 2-PS SMOKE DETECTORS.(((CHANGES MADE TO APPROVED SET. DELTA-4 AND DELTA-5 CHANGES.))) 10/03/13(((CHANGES MADE TO APPROVED SET. CHANGING EST3 GENESIS TO WHEEL LOCK (SPEAKER STROBES.)))New fire alarm system for Broad Museum.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42941	15041-20000-25549	1999 S AVENUE OF THE STARS 14th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 18,525 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42942	19041-10000-32813	10553 N LUBAO AVE	91311	12	207B113   201	2708019016	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM			Verifications in Progress	09/03/2019 12:00:00 AM	ADDRESS	34.26136	-118.56727	[EPLAN] PLAN CHECK FOR GROUND MOUTED 8.96KVA PV1 SYSTEM CONSISTING OF 28 AC MODULES(SPR-X-22-370-D-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42943	19041-10000-41156	1301 W 2ND ST	90026	1	133-5A209 160	5152008024	CW	Central	Westlake	Westlake North		2080.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.06074	-118.25822	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42944	14041-20000-18176	14234 W MARGATE ST	91401	4	171B153   253	2248017015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.16738	-118.4433	5.28KW PV1 roof-mounted system with (22) Enphase M250 microinverters and SolarWorld Plus SW280 Mono modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42945	16041-20000-09702	10660 N WHITE OAK AVE	91344	12	207B129   616	2733009022	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.26397	-118.5195	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement of the basement. Total lighting area = 3,460 sq. ft.Note: Building permit has been pulled under 15016-20000-16923	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42946	18041-20000-21545	8417 W BEVERLY BLVD	90048	5	138B173   416	5514011049	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			Reviewed by Supervisor	07/19/2018 12:00:00 AM	ADDRESS	34.07622	-118.3737	Plan check for power and energy. Project site is an existing commercial building. Project scope is the addition of a 3rd floor and a tenant improvement. Work includes a 600-Amp service and a total lighting area of 8,599 sq. ft.Note: Building application has been generated under 17014-10000-01881	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42947	19041-30002-28782	555 S FLOWER ST 3rd, 4th-flr	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF THE FLOOR LAYOUT AND LIGHTING. ________________________________________________Ti to an existing commerciasl building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42948	12041-10000-06499	7561 N WINNETKA AVE	91306	3	186B113   285	2114005003	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.20762	-118.5713	TITLE 24 ENERGY AND EMERGENCY FOR AUTOMOTIVE REPAIR SHOP. 4000SQFT LIT AREA (INDOOR + OUTDOOR).  EXPRESS PERMIT FOR 23 NEW BRANCH CIRCUITS AND ONE 17KW EQUIPMENT. APPROX 91 AMPS OF TOTAL LOAD. EXPRESS PERMITS FOR TWO NEW 200A PANELS PULLED ON 12041-20000-06432	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42949	16041-20000-00491	10250 W CONSTELLATION BLVD 30th Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for energy only. TI to existing office on 30th floor. New lighting (incl. emergency) and receptacles. 3,720sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42950	19041-20000-53572	15237 W WEDDINGTON ST Unit 2	91411	4	172-5A145 113	2250004065	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	ADDRESS	34.16742	-118.46535	PV2. INSTALL 5.94 KW DC PV SYSTEM WITH (18) MODULES AND MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42951	19041-10000-52889	1950 S SAWTELLE BLVD	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	10/12/2021 12:00:00 AM		Issued	10/12/2021 12:00:00 AM	ADDRESS	34.04129	-118.44377	Fire alarm system for commercial office building.  (476) notification and signaling line devices, FACP, and (10) remote power supplies.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42952	18041-10000-13040	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Apartment			04/17/2018 12:00:00 AM			PC Info Complete	06/06/2018 12:00:00 AM	ADDRESS	34.12626	-118.21412	FULL PC FOR POWER AND ENERGY. INTERIOR WORK FOR AN EXISTING BUILDING.  SCOPE INCLUDES REPLACING AN OIL FILLED 5KV SWITCH WITH TWO AIR SWITCHES, NEW 4800V-277/480 3 PHASE 150KVA TRANSFORMER, NEW PANELBOARDS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 5982 SQ. FT. B#18016-10000-10955	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42953	19041-10000-42877	9301 N TAMPA AVE #  146	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.2392	-118.55379	NEW TENANT OCCUPYING FORMER RESTURANT SPACE- SHARE TEAPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42954	19041-20000-43058	14903 W VICTORY BLVD	91411	6	180B149   840	2235021046	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	08/17/2020 12:00:00 AM	ADDRESS	34.18683	-118.45764	PV3.  Install 20.72 kW DC roof mounted grid tied PV system.  (56) modules with (28) microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42955	19041-20001-04428	17831 W BAHAMA ST	91325	12	195B129   177	2768030004	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.2329	-118.5226	$0 fee due to SB1222 AB1414 plan check only supplemental for changes to approved set. minor relocation of electrical equipment. clouded changes only*original*Plan check for PV roof mounted system and battery back up system, PV system size: 12.21KW DC, 11.24KW AC CEC with 37 PV modules and 37 microinverters and 1 Tesla Power Wall 13.2KWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42956	16041-10000-20317	12735 W BLUFF CREEK DR	90094	11	102B161  1272	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Issued	06/09/2016 12:00:00 AM	ADDRESS	33.97488	-118.41568	PC FOR A NEW FIRE ALARM SYSTEM TO AN EXISTING APARTMENT BUILDING. SCOPE INCLUDES 46 FA DEVICES, 1 FA PANEL, 2 COM. PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42957	10041-20000-25724	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			PC Info Complete	12/28/2010 12:00:00 AM	ADDRESS	33.78808	-118.29535	Pharmacy remodel. Per applicant request for plan check of installing additional receptacle to existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42958	16041-10002-10202	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	10/05/2016 12:00:00 AM	ADDRESS	33.94502	-118.40714	REVISION TO APPROVED SET, ADD LIGHT FIXTURE, PLAN CHECK FOR TITLE 24 ONLY. (RENOVATION OF EXISTING I.T. ROOM IN TERMINAL 3 IN LEVEL2.   NO CHANGE IN OCCUPANCY.RECONFIGURE LIGHTING. PC FOR T24 ENERGY ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42959	12041-10000-07687	145 N LA BREA AVE #D	90036	5	138B181   632	5513002010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM			Not Ready to Issue	01/10/2020 12:00:00 AM	ADDRESS	34.07488	-118.34438	WITHDRAWN.Change to lighting and new receptacles for an existing Retail space.  Not a first time tenant per applicant.  200 Amp load, occupancy load is less than 99 occupants per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42960	15041-10000-31357	12166 W VENTURA BLVD	91604	2	162B165   183	2369014008	C2-1VL-RIO, R4-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Info Complete	10/14/2015 12:00:00 AM	ADDRESS	34.14322	-118.39712	T-24, TI to an existing 1 story commercial building (T-mobile). Existing service and equipement. New lighting and receptacles are being added to the site. Pc for energy only. Sq Ft = 1786.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42961	16041-20000-02285	8320 N OSO AVE	91306	3	192B113   519	2781019010	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.22081	-118.57527	$0 permit fee is due to State Senate Bill SB-1222.  PV1. Install roof mounted PV sysem sized 20 kW. Interconnected with main service panel.(76) Solar World SW285 Modules(76) Solar Edge P300 Power Optimizers(2) Solar Edge SE10000 Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42962	13041-10001-23829	777 S FIGUEROA ST 15TH FLR.	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM			Plans on Hold	01/17/2014 12:00:00 AM	ADDRESS	34.04828	-118.26116	IINSTALLATION OF FIRE ALARM DEVICES DUE TO TENANT IMPROVEMENT. 15TH FLR.((((((((((((((((((((((((((((((((((((((  CHANGES MADE TO PREVIOUSLY APPROVED SET. CHANGES TO SWITCH GEARS, NO LIGHTING CHANGES.))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42963	16041-10000-06619	7718 N HATTON PL	91335	12	189B129  1202	2120008017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.21092	-118.52318	PV1, ROOF MOUNTED SOLAR SYSTEM USING 2 CENTRAL INVERTERS. (34) MODULES,  (1) 6KW INVERTER AND (1) 3.8 KW INVERTER. TOTAL SIZE IS 11.1KW -DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42964	13041-10000-08660	22254 W RUNNYMEDE ST	91303	3	186B101   512	2023023014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.20575	-118.61223	pv1 PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWLELING. TOTAL SYSTEM SIZE 10.3KW USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 42 MODULES, 4 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42965	18041-10000-05037	340 S AVENUE 17	90031	1	136-5A219 642	5447029019	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.06815	-118.22155	"PC FOR T-24 ONLY. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES FOR A WAREHOUSE. TOTAL AFFECTED AREA IS 4600 SQ. FT. B#18016-20000-00481 ""COMPLY WITH DEPARTMENT ORDER effective date  10/19/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42966	12041-10000-28233	14307 W CALIFA ST	91401	2	177B153  1065	2245016014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.17767	-118.44463	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 4.16KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42967	13041-10000-04356	785 N VIGNES ST	90012	14	132A217   391	5409025***	ADP, [Q]M3-1	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.05606	-118.23248	T24 plan check for existing office space. 331 sqrft. Electrical permit to be pulled at electrical plan check counter ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42968	15041-20000-32730	5220 N CALENDA DR	91367	3	171B093   436	2044020032	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.16462	-118.63626	PV1. Install roof mounted PV system sized 11.4 kW. Interconnected with main service panel.(52) Kyocera KU 265 Modules(1) Solaredge SE11400	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42969	16041-20000-04252	1017 N LAS PALMAS AVE 2nd Floor	90038	4	144B185   896	5532026036	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Expired	08/23/2018 12:00:00 AM	ADDRESS	34.08943	-118.33642	Plan check for fire alarm system in existing space. Total devices: 14.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42970	13041-10000-03960	6605 N FALLBROOK AVE	91307	3	180B097   311	2038040015	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.18874	-118.62363	INTERIOR TI OF EXISTING RETAIL SPACE IN EXISTING FALLBROOK MALL SHOPPING CENTER.  NEW ELECTRICAL SYSTEM AND LIGHTING. SINGLE STORY BUILDING, TENANT SPACE SHARING BUILDING WITH A SPROUTS SUPERMARKET.  13,265 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42971	19041-10000-16735	8727 W PICO BLVD	90035	5	132B169   922	4332018045	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.05464	-118.38217	PLAN CHECK FOR NEW FA SYSTEM. SYSTEM INCLUDES 1 FACP AND ABOUT 50 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42972	13041-10000-22266	154 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/21/2013 12:00:00 AM	ADDRESS	34.07457	-118.32342	TITLE-24 , TENANT IMPROVEMENT WORK FOR A BAGEL STAND ; WORK IS FOR  NEW LIGHTS INSTALLATION IN EXISTING RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42973	19041-20000-39441	4653 N VANALDEN AVE	91356	3	168B117   452	2178018007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.15453	-118.55391	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 14.8 KW DC/ 11.4 KW AC. SCOPE OF WORK CONSISTS OF (40) PV MODULES WITH OPTIMIZERS AND A 11.4 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42974	16041-30001-29977	16792 W CHARMEL LANE	90272	11	132B117    32	4420026011	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.05981	-118.55155	Expedite per applicant request(((((Plan check for PV roof mounted system. system size: 14.8kW with 43 modules and 43 AC modules connected to existing MSP.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42975	19041-10000-43406	17819 W LOS ALIMOS ST	91344	12	207B129   197	2712021012	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.2663	-118.52222	(EPLAN) PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 36  (HYUNDAI HIS-S360RI) MODULES, 36 (ENPHASE IQ7PLUS-72-2-US) MICROINVERTERS, 1 ENPHASE COMBINER BOX, 2 TELSA POWERWALL'S, 125A SERVICE SUB PANEL, 1 BACKUP GATEWAY CONNECTED TO AN EXISITING 200A PANEL. SYSTEM SIZE IS 10.44KW AC AND 12.96KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42976	17041-10004-42324	11904 W TENNESSEE PL	90064	11	123B149   896	4259033002	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.03044	-118.44985	CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE INCLUDES CHANGING INVERTER TYPE TO : ABB# UNO-DM-3.3-TL-PLUSTHIS IS PLAN CHECK ONLY!PC for new rooftop solar for 3kW system connected with battery backup(5kW). Installing 10 modules with ABB central inverter, new 225A load center and new backup battery (battery under permit 17041-10003-42324).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42977	10041-10000-01560	11025 W ANZIO ROAD	90077	5	144B145    75	4377019001	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2010 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.09269	-118.4635	New SFD in Bel-Air.  Permit has already been pulled under structural for SFD (Needs to be verified 06010-30000-05347).  P/C is for new service, new equipment, new panels, etc.  Full plans were not available at time of submittal - further plans to be submitted - Fees will need to be verified at p/c : permitting	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42978	18041-10001-21801	176 N CITRUS AVE	90036	5	138B185   122	5513007002	R1V3-RG	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.07586	-118.33954	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.52KWdc / 10.24KWac.(32)AC MODULES- SPR-X22-360-D-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42979	13041-20000-10958	5700 N CANOGA AVE 2ND FLR	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.17365	-118.59715	2ND FLOOR REMODEL FOR OFFICE AREA, TOTAL AREA 18,000 SQ FT. PC FOR POWER AND ENERGY. NEW CONNECTED LOAD TO EXCEED 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42980	19041-20001-43396	3471 W BEN LOMOND PL	90027	4	150B201    55	5591003018	R1-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.11125	-118.28216	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGES MADE TO ROOF PLAN, SINGLE LINE, AND SIGN PLACARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42981	16041-10000-38546	6345 W WILSHIRE BLVD	90048	5	135B173   826	5510028031	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.06379	-118.36685	TI TO MCONALDS. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42982	19041-20000-18577	633 W 5TH ST 2ND FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	T24 ONLY PLAN CHECK FOR EXISTING GIFT SHOP ON 2ND FLOOR OF HIGH RISE BUILDING. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1,151 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42983	15041-10000-29900	113 N GRAND AVE	90731	15	018B197  1121	7451006027	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	33.74356	-118.29024	T-24. PC FOR ENERGY. TI ON EXISTING COMMERCIAL BUILDING (GYMNASIUM). SCOPE INCLUDES REPLACING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AREA IS 7292 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42984	19041-20000-22448	1927 N NORMANDIE AVE pv1	90027	4	150A195    93	5589008013	RE9-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.10633	-118.30069	pv1install roof mounted pv system sized 14.8KW AC, 15.51KW DC with 47 PV Modules and 47 microinverters interconnected with msp.Note: Fess $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
42985	09041-10003-02345	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	ADDRESS	34.04896	-118.25139	relocated MV 300kva transformer from the 12th floor to the 14th floor; added MV fused disconecct on the primary of the MV transformer which supplies a 800A panelboard relocated from the 12th to the 14th floor. this 800A panelboard supplies the pump motors which were supplied from a 240V 3ph distribution board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42986	17041-10002-04741	2580 W OLYMPIC BLVD	90006	1	129B197   330	5076008018	C2-2D	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	34.05219	-118.28726	"REVIEW OF PLANS INCORPORATING CHANGES MADE IN THE FIELD; PERMIT WAS OBTAINED ON 17041-100001-04741((((1ST REVISION TO APPROVED PLAN NOTED AS DELTA-2, SOW INCLUDES:  ADD (1) 100A PANEL 'C"" WITH 26 NEW CIRCUITS TO (E) DP DIST. BOARD.; REVISE LIGHTING FLOOR PLAN AND T24 ACCORDINGLY."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
42987	16041-20004-24899	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Info Complete	05/04/2017 12:00:00 AM	ADDRESS	33.93576	-118.3779	changes to an approved set of plans.  changes noted delta 9.  changes include new outdoor lights and new circuits.Total affected area of 5882 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42988	17041-10000-07768	555 W 5TH ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC for energy only, title 24. Installing new lighting. Replacing extisting lighting with new LED lighting. Renovatoin of public spaces on concourse and lobby levels. Area: 4199.Permit fee was paid under application number  17041-90000-04072PC only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42989	12041-20001-12498	20628 W VINTAGE ST	91311	12	204B109   505	2741028052	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.25164	-118.58297	Photovoltaic system on roof of single family dwelling using enphase inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42990	15041-10002-20349	19602 W LANARK ST	91335	3	189B117    95	2105003006	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.21785	-118.56051	$0 fees due per California Senate Bill 1222Revision to approved set (PC only, Permit under Master E#). Revised qty of modules from 30 to 24. Upgrade the size of main breaker and Bus rating of the main panel. All other remain sthe same.<<PV1, INSTALL 9.81 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (30) MODULES: SUNPOWER SPR327NE-WHT-D(3) INVERTERS: SMA SB3000TL-US-22>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42991	15041-20000-41530	14345 W AZTEC ST	91342	7	219B149   641	2507025021	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.29548	-118.44589	PV1.  Install 6.27 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.  (22) SolarWorld SW285 Mono panels w/ SE-6000A-US transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
42992	11041-10000-03342	911 S HILL ST	90015	9	127-5A209 183	5139004018	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.04281	-118.2576	FULL PLAN CHECK NEW RESTAURANT.  FIRST FLOOR.   EXISTING 2-STORY BUILDING.  FIRE ALARM SYSTEM IS TO BE UNDER A SEPERATE PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42993	16041-20000-16089	3751 E OLYMPIC BLVD	90023	14	118-5A229  71	5191003001	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.01903	-118.19444	PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE FROM RETAIL TO 8-UNIT JOINT LIVING & WORK QUARTERS & ONE RETAIL  TENANT SPACE.BUILDING PERMIT # 16010-10000-02726	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42994	18041-20000-11901	3524 S CHESAPEAKE AVE	90016	10	120B181  1057	5046015026	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Apartment			04/03/2018 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.02305	-118.34505	Plan check for power and energy. Project site is a 3-story, 27-unit apartment building with basement parking garage. Work includes a 1,200-amp service and a total lighting area of 14,780 sq. ft.Note: Building application has been generated under 18010-20000-00905	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42995	13041-10000-12058	380 WORLD WAY #T27-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM			Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check power and energy. First-time tenant in retail space at Tom Bradley Int'l Terminal at LAX (See's Candies). Space #T27-R	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
42996	12041-10000-00174	10250 W CONSTELLATION BLVD # 26th fl	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	34.05735	-118.41746	alterations in office areasplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42997	11041-10002-03163	303 S GAFFEY ST	90731	15	018B197  1550	7451020033	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro	YES	2966.00	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM			PC Approved	08/18/2011 12:00:00 AM	ADDRESS	33.74122	-118.29251	CHANGES TO APPROVED T-24 PLANS. INSTALL ADDITIONAL 12.5W, GU24, LED LIGHTS INSTEAD OF CFL LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42998	19041-10000-18544	7330 N VARNA AVE	91605	2	186B157   452	2328028001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.2038	-118.42457	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
42999	14041-10000-08750	8301 W BEVERLY BLVD	90048	5	138B173   395	5514009027	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.07623	-118.37013	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. 1 FIRE ALARM CONTROL PANEL, 1 ANNUNCIATOR, AND 27 DEVICES. PERMIT HAS BEEN PULLED ON APPLICATION#: 14041-10000-04453	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43000	17041-20001-19002	23344 W CALIFA ST	91367	3	174B093    57	2041007007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.17656	-118.63578	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.8 kWac and consists of (43) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43001	15041-10000-32099	935 N HUDSON AVE	90038	13	144B185  1027	5533023005	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			09/28/2015 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.08815	-118.33232	PC FOR POWER AND ENERGY ON A NEW 3-STORY, 6 UNIT APARTMENT BUILDING AND A PRIVATE GARAGE.  TOTAL INDOOR AND OUTDOOR AREA IS 9561 SQ. FT. Project is in a methan buffer zone.Note: Building permit has been pulled under application 13010-20000-04604	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43002	19041-10000-43098	767 S ALAMEDA ST Unit# 460	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	"TI IN AN EXISTING COMMERCIAL AREA IN UNIT #460. INSTALLING lIGHTS.  ""Emergency Lights"" & ""EXIT"" signs are exiting to remain. T-24 ENERGY ONLY. AFFECTED AREA: 4,484 SFT. BLDG PERMIT: 19016-10000-32620"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43003	19041-10000-25967	407-413 E 5TH ST	90013	14	127-5A213 130	5148011003	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM			Verifications in Progress	10/27/2020 12:00:00 AM	ADDRESS	34.04461	-118.2446	FULL PLAN CHECK FOR A NEW AFFORDABLE HOUSING APPARTMENT COMPLEX. 8 STORY LOWRISE BUILDING, 150 UNIT APARTMENT BUILDING WITH OFFICES ON THE 1ST FLOOR. THIS BUILDING IS CONSTRUCTED WITH PRE-FABRICATED MODULAR UNITS WHICH WILL BE APPROVED BY THE STATE.SCOPE INCLUDES NEW 2000A SERVICE WITH 30 HP FIRE PUMP.  B#19010-10000-01500	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43004	16041-30000-12160	9039 N WHITAKER AVE	91343	12	195B133    16	2688025032	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM			Reviewed by Supervisor	04/19/2016 12:00:00 AM	ADDRESS	34.23501	-118.49925	Installation of new roof mounted solar PV array on existing single family dwelling.   Total system size = 10 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43005	17041-10000-04421	12771 W SHELL PL	90094	11	102B161  1270	4211037026	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	33.9747	-118.41672	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 4 STORY, THREE UNIT CONDO APARTMENT BUILDING. SCOPE INCLUDES 59 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43006	16041-20001-24579	803 E 25TH ST	90011	9	120A209   318	5131022025	R3-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.02162	-118.25858	Expedited per applicant request.Plan check for a Pv1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (10) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43007	16041-10002-09578	4910 N DUNMAN AVE	91364	3	168B097   165	2074006016	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM			PC Approved	09/02/2016 12:00:00 AM	ADDRESS	34.15931	-118.62679	CHANGES TO APPROVED SET OF PLANS. REVISED LAYOUT AND ADDED DWP METER SOCKET. NO OTHER CHANGES. CLOUDED ON PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43008	18041-30000-13378	6927 N REMMET AVE	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			Corrections Issued	04/12/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	Plan check for a PV2 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (15) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43009	10041-10000-00469	1807 E OLYMPIC BLVD 1ST FLOOR	90021	14	121-5A215  43	5166027004	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	04/26/2010 12:00:00 AM		Permit Finaled	08/31/2010 12:00:00 AM	ADDRESS	34.02765	-118.23864	TI IN AN EXUISTING WAREHOUSE & KITCHEN AREA ON THE 1ST FLOOR. PLAN CHECK IS FOR TITLE 24- ENERGY CALCS & EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43010	15041-10000-25008	800 N ALAMEDA ST RTL #2-E. PORTAL	90012	14	132A215    65	5409023941	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	34.05494	-118.23752	NEW 240 SF FOOD KIOSK INSIDE TRAIN STATION. PLAN CHECK FOR ENERGY ONLY.  SCOPE OF WORK TO BE PERFORMED IN RETAIL # 2 EAST PORTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43011	17041-20000-33962	10848 N SWEETWATER CT	91311	12	210B117   337	2708027***	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.26788	-118.56479	Plan check for solar pv system, roof-mounted array on SFD.7.68kW ungrounded system. (24) 320W ac modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43012	17041-10000-04467	419 N HAWAIIAN AVE BLDG 3	90744	15	027B201   421	7417005901	[Q]RD2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM				Installation of  a new fire alarm on building 3. all part of lot 1. this is project 1/4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43013	19041-10000-48000	333 S GRAND AVE 17TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 940 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43014	14041-10000-22828	951 S CROCKER ST #1	90021	14	124-5A211 161	5132001100	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.03538	-118.25024	Title 24 plan check only.  Total area = 2,692 sq. ft.Remove HID lights fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43015	14041-10001-29469	961 W 43RD ST	90037	9	114B197   997	5020034027	[Q]R4-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Apartment			08/17/2017 12:00:00 AM			PC Approved	08/17/2017 12:00:00 AM	ADDRESS	34.00559	-118.29043	Changes to approved set per inspection corrections. Scope includes relocation of inverters and downgrading service (from 400 to 200A)Plan check only!permit for service downgrade under express permit ( NOT PART OF PV WORK)$0 permit fee is due to State Senate Bill SB-1222.  Installation of new 31.2 kWac rooftop solar array.  120 modules with 12 strings (10 modules per string) connected to 6 inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43016	17041-10002-15044	1051 S QUEEN ANNE PL	90019	10	132B185   753	5082001011	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.05558	-118.33003	EXPIDITE FEEPC FOR ROOF MOUNTED PV SYSTEM WITH AC CONNECTED BATTERY.SYSTEM SIZE 7.6 KWAC (SOLAR EDGE)TESLA  POWER WALL 1 BATTERY 3.3 KW (DC/DC)INCLUDING 8 MOUDULES WITH OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43017	14041-20000-14218	13812 W SATICOY ST	91402	6	186B153    43	2214023003	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.20979	-118.43395	Roof mounted PV system on commercial building.  PV system size 13KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43018	11041-20000-27697	127 S SAN VICENTE BLVD Bulletin-125TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM			PC Approved	12/30/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin # 125T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43019	18041-10000-01961	11401 N PORTER RANCH DR Rec. Build	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	09/14/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	PC FOR POWER AND ENERGY FOR A NEW RECREATIONAL USE BUILDING FOR ADJACENT RESIDENTIAL COMMUNITY. PART OF A CAMPUS STYLE RESIDINTIAL COMMUNITY. 1 STORY 35160 S.F BUILDING #11 OF 11B# 17010-10000-04955	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43020	15041-10000-23532	6172 E MOUNT ANGELUS DR	90042	1	153A231   114	5484033028	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Expired	08/17/2017 12:00:00 AM	ADDRESS	34.11454	-118.18747	PV1 starndard plan 6.0KW roof-mounted system with (1) inverter and (25) Kyocera KU260 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43021	19041-10000-08246	4721 E KLAMATH ST	90032	14	139-5A231  32	5214018900	[Q]OS-1XLD	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.0757	-118.18153	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43022	11041-20000-09830	16780 W OAK VIEW DR	91436	5	168B137   480	2289022015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	ADDRESS	34.15607	-118.49838	PLAN CHECK FOR NEW SINGLE FAMILY DWELLING WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43023	13041-10001-35618	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	33.98173	-118.4029	((10/28/2014 - Sup. application for changes to approved set.  Removing some lighting fixtures and change of service from overhead to underground))PLAN CHECK FOR POWER AND ENERGY. CORE AND SHELL. NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY 29775 SF WITH NEW SURFACE PARKING LOT2 of 2. BUILDING 2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43024	10041-20000-03987	7217 W FOOTHILL BLVD	91042	2	202-5A199 386	2568012025	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	03/10/2010 12:00:00 AM		Permit Finaled	05/10/2010 12:00:00 AM	ADDRESS	34.24894	-118.28897	TENANT  IMPROVEMENT  Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43025	15041-20000-00870	4425 N CANOGA AVE	91364	3	166-5A107 173	2190014022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.14993	-118.5957	PV1. Install roof mounted PV system sized 9.84 kW. 400A split bus. Interconnected with main service pannel.(41) Sunmodule SW 285 Mono modules(41) Enphase M250 microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43026	16041-10000-09817	12667 W SUNRISE PL	90094	11	102B161  1275	4211037031	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.97673	-118.41398	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.08KWdc / 1.904KWac, WITH AN AC MODULE SUPERVISOR. (8)AC MODULES-SPR-X20-250-BLK-B-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43027	10041-20000-14856	14208 W OXNARD ST	91401	2	177B153   862	2245018011	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	11/17/2010 12:00:00 AM	ADDRESS	34.17915	-118.44245	New service for autorepair. Energy only. No outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43028	13041-20000-28119	11315 S FIGUEROA ST UNIT 110	90044	8	087A201   235	6075026029	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	PIN	33.93143118	-118.28297189	PC FOR T24 ENERY ONLY. LOW LOAD. PERMIT ALREADY ISSUED. PERMIT # 13041-70000-23868	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43029	12041-20000-19074	123 S LA BREA AVE	90036	5	138B181   965	5513019012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.07284	-118.34424	Plan check for energy and emergency lighting. 1251 sqft. Steven Alan La Brea. Clothing store. Tailored Method.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43030	16041-20000-39798	4210 S DEL REY AVE	90292	11	105B153    19	4230005009	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	33.98723	-118.44379	Plan check for power and lighting. Project site is a new 6-story, 68-unit aparmtment building: 4 levels of residential over 2 levels of parking garage. Total lighting area = 73,529 sq. ft. Area is a methane buffer zone.Note: Building application has been created under 15010-10000-04084	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43031	17041-10000-18333	2328 W 73RD ST	90043	8	102B189  1577	4009008012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	33.97356	-118.31966	PC FOR ROOF MOUNTED PV SYSTEMSYSTEM SIZE  3KWACINCLUDES:CENTRAL INVERTER  SE3000H-USOPTIMIZERS SE-P400INCLUDES 8 MODULES ( MAXPOWER CS6U-320P)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43032	14041-20000-02357	5815 W SUNSET BLVD 2ND FLOOR	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.09822	-118.31613	PC FOR T24 ENERGY ONLY. TOTAL AREA 4816 SQ FT. EXISTING OFFICES NEW LIGHITNG. WORK DONE IN BUILDING B SECOND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43033	17041-30001-43722	13488 W MAXELLA AVE	90292		105B153    77	4212004032							Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	33.98592	-118.44252	03-22-2018 Changes to an approved set of plan. Changes include lighting fixture layout. Changes apply to delta 5 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43034	17041-10000-25430	511 S ALEXANDRIA AVE	90020	10	135B197   814	5502019010	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	06/17/2022 12:00:00 AM	ADDRESS	34.06492	-118.29811	PC FOR APARTMENT 4 STORY, 29 UNITS. PC FOR POWER AND ENERGY.  B#16010-10000-01968	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43035	10041-20000-18291	1800 N HIGHLAND AVE	90028	4	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			09/15/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.10436	-118.33763	Plan check T-24 energy (general/emergency) lighting for office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43036	11041-10000-07811	514 S PIER A ST	90744	15	024B205     4	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM			PC Approved	05/03/2011 12:00:00 AM	PIN	33.76550707	-118.26902378	T-24, OTC PLAN CHECK AT PORT OF LA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43037	19041-20000-03042	24236 W STONE BEND LANE	91304	12	192B089   225	2017038026	RE9-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.21986	-118.65572	Plan check for a PV1 roof-mounted PV system. System size is 2.835 kWdc/3 kWac and consists of (1) inverter and (9) modules. MSP is rated for 400 Amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43038	13041-20000-17404	11350 W ALLEGHENY ST	91352	6	201B173   290	2538024002	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.24802	-118.37795	New microinveters for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43039	19041-20000-04912	1082 W 37TH ST	90731	15	006B193   300	7469022066	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	33.71353	-118.30341	Plan check for PV roof mounted system and battery back up system, PV system size: 8.12KW DC, 7.6KW AC with 28 PV Modules and 1 inverter(7.6kW ) and LG battery 9.8KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43040	17041-20000-32656	700 S MANHATTAN PL	90005	4	132B193   331	5093004068	R4-2	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.05945	-118.31002	Plan check for fire alarm system. New fire alarm system for a 7-story (over 2 levels subtarranean garage) mixed use building. 1 FACP. 670 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43041	14041-10001-10879	608-612 S MATEO ST	90021	14	126A217   187	5164013013	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.0376	-118.23251	REVISIONS TO PERMITTED SET OF PLANS; AC UNITS HP RATINGS WERE  REDUCED SUCH THAT THE LOAD ON PANEL  A  IS GREATLY REDUCED;INCLUDED A  PANEL X FOR EXISTING BRANCH CIRCUITSplan check for power and energy. T24 done as performance - applicant to bring in prescriptive method. 1 story.  Methane Buffer zone. Installation of 600A equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43042	19041-10000-49050	12454 W WAGNER ST	90066	11	108B157  1522	4221005038	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	02/14/2022 12:00:00 AM	ADDRESS	33.98893	-118.42093	(E-PLAN)INSTALLATION FOR AN EXISTING SERVICE OF 100 AMPS. INSTALLATOIN INCLUDES 2 NEW ENERGY STORAGE SYSTEM AND 1 PANEL OF 200 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43043	19041-10000-01441	304 S BROADWAY STE 420	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.05076	-118.248	PLAN CHECK FOR TITLE 24 ONLY TENANT IMPROVEMENT TO AN OFFICE TOTAL SQFT 1955.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43044	18041-10000-23762	19191 S VERMONT AVE STE. 820	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLAN CHECH FOR TITLE 24 ONLY FOR - TI WORK ON APPROX. 2,892 SF OF THE TOTAL FLOOR AREA. NEW NON-LOAD BEARING INTERIOR PARTITIONS, POWER, LIGHTING AND FINISHES. - TOTAL AFFECRTED AREA = 2890 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43045	19041-10000-45823	9569 N DORRINGTON AVE	91331	6	201B153   898	2644019004	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.24461	-118.44558	NEW ROOF MOUNTED 4.96KW PV SYSTEM WITH 16 @ (310W) PV PANELS AND OPTIMIZER AND ONE 5KW CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43046	11041-10000-00980	9601 S AVIATION BLVD	90045	11	093B173   308	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	33.94983	-118.37793	NEW COMPRESSED NATURAL GAS (CNG) FUELING STATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43047	16041-10000-00941	9901 S STANFORD AVE	90002	8	093A207   410	6050026004	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	33.94668	-118.26258	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.78KWdc / 3.15KWac. (14)MODULES-SUN EDISON SE-F270CZC(14)MICROINVERTERS-ENPHASE ENERGY M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43048	16041-20000-28727	6430 W SUNSET BLVD Suite 400	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.09782	-118.32979	Plan check for energy only. TI in suite 400. Two new offices with relocated lighting. New receptacles. 604sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43049	18041-10004-02140	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	33.94221	-118.40701	Change to an approved set by combining existing change to this application. Scope includes adding new ckts and modify some lighting and power plan. All changes under delta-4 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43050	13041-10001-02644	590 N VERMONT AVE	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Approved	07/31/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	>>aDDING DEVICES AND REPLACING PANEL TO ALREADY APPROVED AND PERMITTED fIRE aLARM SYSTEM---------ORGINAL APPROVAL UNDER 13041-10000-02644	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43051	18041-10000-41256	8414 S HOLY CROSS PL	90045	11	096B161   395	4113005005	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	33.96134	-118.41548	NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 2.1KWdc / 1.96KWac. PV SYSTEM IS  CONNECTING TO THE POINT OF INTERCONNECTION OF A SINGLE FAMILY HOME.(7)MODULES-SOLARWORLD SW 300(7)MICROINVERTERS-ENPHASE S280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43052	17041-10000-19505	243-249 S MISSION ROAD	90033	14	127-5A217 111	5172014018	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.04459	-118.22788	PLAN CHECK FOR POWER AND ENERGY FOR TI. SCOPE OF WORK INCLUDES NEW PANELS, EQUIPMENT, LIGHTING ON EXISTING DISTRIBUTION EQUIPMENT. CONNECTED LOAD >400A. TOTAL AFFECTED AREA 15094 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43053	15041-20000-33120	6616 N CAPISTRANO AVE	91307	12	180B101   318	2038030011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.1908	-118.61651	PVI. NEW ROOF MOUNTED SOLAR SYSTEM ON A RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 6KW AC. (21) MODULES-TRINA SOLAR TSM-250 PD05.05(2) INVERTERS-ABB PVI-3.0-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43054	18041-10000-18478	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.23567	-118.5584	FIRE WARNING SYSTEM FOR A 6 STORY MIXED-USE APARTMENT BUILDING. SCOPE INCLUDES 1027 FA DEVICES AND 2 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43055	11041-20000-16059	12729 W RIVERSIDE DR	91607	5	168B161   417	2357018007	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.15778	-118.41052	PLAN CHECK POWER AND ENERGY FOR NEW 47 UNITS 3- STORY APT BLDG OVER 1-STORY PKG GARAGE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43056	15041-10000-21660	783 W GATUN ST Unit #301	90731	15	021B197  1087	7445002117	[T][Q]RD1.5-1	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	33.75748	-118.29434	PV 1 roof mounted solar array, system size 4.94 KW.(1) Inverter: PVI-4.2-OUTD-US-Z-A(19) Modules: KU2606XPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43057	13041-10001-32032	20705 W CAMPANIA LANE	91326	12	213B109   543	2701070050	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.28031	-118.58414	Expedited rooftop solar plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43058	14041-10000-24542	4620 N TILDEN AVE	91423	4	168A151   109	2265013023	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Expired	04/12/2017 12:00:00 AM	ADDRESS	34.15558	-118.44746	INSTALL 16830 W DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(66)MODULES: SUNIVA OPT 265-60-4-100(2) INVERTER(S): SMA AMERICA SB7000US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43059	17041-10000-34430	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	33.98095	-118.40764	PC for power and energy for educational facilty first time tenant in second floor. Total area of 35520sqft.Installing 8 new panels, 4 transformers, equipment, lights and receptacles. Building# 17016-10000-28097	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43060	17041-20000-12641	15948 W WYANDOTTE ST	91406	6	186B141   786	2206036028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.20283	-118.48126	PV1.  Installation of a 3.8 kW roof mounted grid tied PV system.  Online permit initially filed for the work under 16041-90000-40521 - work falls under 2014 LAEC requirements.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43061	17041-10000-37850	1978 E CESAR E CHAVEZ AVE	90033	14	129A223    91	5183001054	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Issued	10/20/2017 12:00:00 AM	ADDRESS	34.04888	-118.21295	TITLE 24 ONLY, RELACE OUTDOOR METAL HALIDE EXISTNG FIXURES WITH NEW LED FIXURES, TOTAL SQUARE FOOTAGE 1353 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43062	16041-20000-00798	232 E 2ND ST	90012	14	129A213    28	5161024034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	Plan check for 1st time tenant for Starbucks Coffee in mix use building(Multi units dwelling and commercial). Total area: 1,827 sq ft.Building Application #: 15016-10000-28333	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43063	16041-20000-04874	20754 W LUGANO WAY	91326	12	213B109   283	2701065001	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.27826	-118.58526	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (46) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43064	17041-10001-36605	2010 W 62ND ST	90047	8	105B189  1017	6001020015	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	33.98325	-118.31394	EXPEDITE PER APPLICANT REQUESTPC FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL BUILDING. SYSTEM SIZE 19.8KWDC / 23KWAC. SCOPE INCULDES 66 PANELS WITH SINGLE INVERTER. ADDITIONAL SYSTEMS ARE INSTALLED ON SAME ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43065	16041-10000-12506	1175 E 21ST ST	90011	9	120A211   109	5131009036	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.02369	-118.25356	PV1 rooftop solar installation on Duplex SFD, 2.15 kW AC.     (10) MODULES-HYUNDAI HiS-M250MG      (10) MICROINVERTERS-ENPHASE M215-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43066	19041-20000-39012	5351 N BEVIS AVE	91411	4	172-5A149  74	2249024002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.16816	-118.45649	PV1.  Install 11.4 kW AC / 12.7 kW DC roof mounted grid tied PV system.  (41) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43067	13041-10000-03946	1201 S LA BREA AVE	90019	10	129B181    91	5084028060	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	ADDRESS	34.05316	-118.34389	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING RETAIL TENANT INPROVEMENT. INDOOR AND OUTDOOR. PERMIT TO BE ISSUED BY PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43068	19041-10000-53291	7054 N SEMRAD ROAD	91307	12	183B089   266	2028032001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.19878	-118.65026	NEW PV1 ROOFMOUNTED SYSTEM CONSIST OF 19 MODULES (MSE310), 19 OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTER (SE7600H-US). THE NEW SYSTEM IS COMBINED WITH EXISTING 6KWAC SYSTEM.  TOTAL SYSTEM SIZE IS 13.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43069	18041-10000-32668	915 N SYCAMORE AVE	90038	4	144B181   746	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.08769	-118.34291	REMODELING OF WAREHOUSE RETAIL/OFFICE SPACESADDED LOAD IS LESS THAN 400APLAN CHECK IS FOR TITLE 24 AND 1 EMERGENCY CIRCUIT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43070	11041-20000-24728	1700 S OGDEN DR	90019	10	126B177   129	5069004001	R1-1	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.04501	-118.36601	Plan check roof mounted Enphase Microinverter photovoltaic system on single family dwelling. Variance to install M215 prior to testing agency approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43071	14041-10000-32353	6344 N TOPANGA CANYON BLVD Building A	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Info Complete	06/30/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	Power plan check for new electrical equipment related to outdoor lighting systems for common area of Westfield Topanga outdoor mall only. Circuits that are part of scope of work have been highlighted on the panel schedules. Single line diagram provided for reference only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43072	10041-20000-13980	19341 W GERMAIN ST	91326	12	207B117   406	2728006009	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	10/12/2010 12:00:00 AM	ADDRESS	34.26131	-118.55474	pv system for single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43073	16041-20000-36145	1541 S CENTRAL AVE	90021	14	121-5A211 260	5132023027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.02676	-118.24871	ti to an existing commercial single story food mart.  adding new lighitng new controls to existing panels.  plan check for energy and em lighitng only.  total square footage 1540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43074	17041-20000-21333	3470 W WILSHIRE BLVD	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.06152	-118.3001	Plan check for a PV2 roof-mounted PV system. PV system installation on a parking canopy on top of a parking structure. System size is 300 kWac and consists of (5) inverters, (1,044) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222. Building permit  # 17014-20000-03029	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43075	13041-10000-34621	4778 W ADAMS BLVD	90016	10	123B181  1012	5057010017	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.03237	-118.34456	Remove HID light fixtures and replace with new fluorescent fixtures in auto repair shop.  Plan check for Title 24 lighting requirements and associated permit.. For autoshop (NON-HAZARDOUS PER APPLICANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43076	18041-20000-08482	15000 W CORONA DEL MAR	90272	11	123B129   711	4411030007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	09/07/2019 12:00:00 AM	ADDRESS	34.03145	-118.52276	Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (3) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43077	10041-20001-12354	10960 W WILSHIRE BLVD 6TH FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM			PC Approved	12/27/2010 12:00:00 AM	ADDRESS	34.058	-118.44597	REVISION TO APPROVED PLANS. DELTA 3 REVISION TO CHANGE EMERGENCY LIGHTING LAYOUT ON 6TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43078	13041-10000-06290	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	NEW 3 STORY LIFE/SCIENCE BUILDING WITH 3-STORY SUBTERRANEAN PARKING GARAGE. PLAN CHECK POWER AND ENERGY SITE LOCATED IN METHANE ZONE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43079	10041-10001-03132	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM			PC Approved	10/14/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	PLAN CHK APPLICATION IS TO REVIEW NEW SET OF PLANS AS AS-BUILT PLANS. ALL CHANGES ARE CLOUDED. ITEMS ARE MOVED AROUND ON THE PANEL SCHEDULES AND ARE RELOCATED  (((((((((NEW SERVICES AND FEEDERS TO SUPPLY POWER TO  EXISTING AND NEW STRUCTURES  AT HOTEL BEL-AIR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43080	19041-20000-09242	4517 N NATOMA AVE	91364	3	166-5A111  26	2174016014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.15199	-118.57995	pv1install roof mointed pv system sized 5.2KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43081	17041-10000-22796	11601 W WILSHIRE BLVD 20TH FLR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR RESTROOMS CORRIDOR AND LOBBY  TI IN A HIGH RISE (20th FLOOR) FOR TITLE 24  ENERGY ONLY. TOTAL AFFECTED AREA  1600 SQ.FTINSTALLING NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43082	17041-20001-23031	15900 W HARVEST ST	91344	12	213B141   255	2666007010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	34.27797	-118.47825	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.35 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43083	18041-10000-45355	200 N SPRING ST	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	06/22/2021 12:00:00 AM	ADDRESS	34.05405	-118.24317	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING BUILDING LA CITY HALL. SCOPE OF WORK INCLUDES 103,703 SQFT OUTDOOR/FACADE LIGHTING FOR PHASE 1 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43084	14041-20001-05126	417 S BARRINGTON AVE	90049	11	132B145   106	4401010011	R3-1, RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			06/01/2018 12:00:00 AM			PC Approved	06/01/2018 12:00:00 AM	ADDRESS	34.06037	-118.46868	Supplemental for changes to approved set of plans on relocation of service equipment and feeding both 800A distribution equipment with AL feedders. Changes clouded under delta ENEW 34 UNIT APARTMENT BUILDING. METHANE BUFFER ZONE, fire alarm variance was filed, pc extensions were filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43085	14041-20001-02278	15756 W COVELLO ST	91406	6	186B141   191	2206014016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.20743	-118.47687	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING SOLAREDGE TOTAL SYSTEM SIZE 4.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43086	15041-10000-14363	10906 W LE CONTE AVE	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.06347	-118.44568	TI-24 TO AN (E) COMMERCIAL 2 STORY BUILDING. ADDING NEW LIGHTING. TOTAL SQ. FT. 1320	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43087	14041-20000-13770	5723 W MELROSE AVE	90038	13	141B189   279	5534036018	C2-1D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.0836	-118.3252	Commercial office TI.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43088	16041-20000-39136	6430 W SUNSET BLVD Suite 1500	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.09782	-118.32979	Plan check for energy only. TI to office suite 1500 on 15th floor of high rise building. New lighting (incl. emergency) and receptacles. 4,674sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43089	18041-20001-05455	13318 W WINGO ST	91331	6	198B157   171	2625002008	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.24214	-118.42337	Expedited plan check fee.PV1.  Installing 12.025 kW DC roof mounted grid tied PV system.  (1) 10kW rated central inverter with (37) 325W PV modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43090	18041-30000-14067	10750 W WILSHIRE BLVD	90024	5	132B153   247	4325004***	[Q]R5-3-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			04/17/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.06002	-118.43844	Plan check for the replacement of a FACP and the addition of fire alarm devices onto an existing fire alarm system for a high-rsie building. There are (108) devices being added onto the system for a total device count of (389) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43091	18041-10000-46407	10443 W ARMINTA ST	91352	2	189B177   304	2407016027	[T][Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.21418	-118.35887	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43092	14041-20000-16834	12737 N GLENOAKS BLVD	91342	7	222B153   859	2508027025	QC2-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.30159	-118.44224	New drive thru cigarette kiosk - Tobacco Shop - (The hours of operation will be from 7 a.m. to 11 p.m.).  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43093	19041-10000-39306	3400 W OLYMPIC BLVD	90019	10	129B193   301	5081031025	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.05245	-118.31249	New fire alarm system in an office space. system consist of 1 fire alarm panel, 1 communicator, 3 power supplies and 99 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43094	14041-10000-02092	1609 N MAGNETIC TER	90069	4	147B169   322	5561013022	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	34.10018	-118.39177	PLAN CHECK ONLY FOR SINGLE FAMILY DWELLING PER INSPECTOR'S REQUEST. COLD WATER PIPE CONNECTION IS DONE AS INDICATED WITH RED CLOUDS ON THE PLANS, EXPOSED ON THE FACE OF THE BUILDING; EMT , WITH COPPER WIRE #1 AWG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43095	15041-20000-09903	8683 N CANTERBURY AVE	91402	6	195B157  1132	2627027072	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.22751	-118.42248	Installation of new roof mounted solar PV array.  Total system size = 4.2 kWac.  Single inverter system with 2 strings of 7 modules each.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43096	14041-10000-19782	5201 N LAUREL CANYON BLVD	91607	2	171B165  1234	2347018012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.16518	-118.39681	Title 24 plan check only.  Total area = 2,170 sq. ft.TI to existing bank.  Installation of new ATMs and remodeling counter area.(((Permit pulled 11/04/2014)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43097	16041-10000-37059	700 S MANHATTAN PL 1-160	90005	4	132B193   419	5093004003	R4-2	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.05945	-118.31002	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 7- STORY(MIX-USE) BUILDING. 160 UNITS WITH 19 TYPICAL UNITS. TOTAL SQ. FT. 145083.SERVICE SIZE = 5000A - 120/208V CLASS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43098	18041-10000-19536	1000 W FRANCISCO ST	90502	15	057B197    63	7351034058	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.84969	-118.29414	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43099	17041-10000-15689	13131 W BARBARA ANN ST	91605	2	183B157   105	2327014900	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.20035	-118.41929	T24 ONLY. REPLACE EXISTING HID LIGHT FIXTLURES WITH NEW LED LIGHT FIXTURES. TOTAL ARE  A  17800 SQ FT. INDOOR  LLIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43100	12041-10001-24373	420 E 3RD ST 600	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM			PC Approved	11/01/2012 12:00:00 AM	ADDRESS	34.04686	-118.24182	Plan check T24 Energy for office spaces. #600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43101	17041-20000-21346	8301 S DELGANY AVE	90293	11	096B153   691	4115003024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	33.9589	-118.44197	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.73 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43102	11041-10000-20863	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	ADDRESS	34.02224	-118.28008	7268  sf   OF INTERIOR  IMPROVEMENTS  AT A FRESH & EASY MARKET	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43103	15041-10000-31712	8520 S BROADWAY	90003	9	097-5A203 256	6040009027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			Corrections Issued	09/24/2015 12:00:00 AM	ADDRESS	33.96097	-118.27809	PC for energy only.  Installation of new electrical device. Remodelling of existing office H&R Block in 2 story building. Total area:1177 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43104	16041-10000-44707	6344 N TOPANGA CANYON BLVD #2040	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.18628	-118.60544	PC FOR POWER AND ENERGY. TENANT IMPROVEMENT TO (E) MEDICAL OFFICE. CONNECTED LOAD <400A , TOTAL AREA . 492 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43105	19041-20000-16794	8633 N BALBOA BLVD NO 18	91325	12	195B133   469	2690021***	QRD1.5-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Apartment			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.22775	-118.50281	Plan check for PV roof mounted system, PV system size: 5.4KW DC, 3.8KW AC with 18 PV Modules and 1 inverter(3.8KW) Note to Inspector: please verify 400A Equipment AIC rating.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43106	17041-10000-14469	1839 S PANDORA AVE 1-4	90025	5	132B157   911	4317002022	RD1.5-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			05/02/2017 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	09/14/2021 12:00:00 AM	ADDRESS	34.05552	-118.42445	PC for 4 unit apt. building. Scopw includes a new service rated 600A 120/240V. Total affected area 1871 sq.ft.B# 14010-10000-02207	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43107	11041-10000-17790	4910 E HUNTINGTON DR SOUTH	90032	14	142-5A233  11	5218008029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.08668	-118.17628	Remodel exiting Food 4 Less.  All new electrical.  Plancheck for power, emergency lighting, and T24 compliance	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43108	15041-10000-27528	7193 W FORMOSA FUSION CT	90046	5	141B181  1713	5525003038	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08571	-118.34581	PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43109	12041-20000-24081	6765 N LANKERSHIM BLVD	91606	2	180B169    68	2322015017	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.03, 1232.05	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	34.19366	-118.38798	Optometrist/Retail change of lighting and receptacles. Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43110	16041-10000-30143	17552 W HAMLIN ST	91406	6	180B129   751	2229027023	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Expired	10/05/2018 12:00:00 AM	ADDRESS	34.1884	-118.51613	5.17 kw ROOFMOUNT SOLAR, 15 MODUELS, 1 INVERTER, 15 OPTIMIZERS PV DISCONNECT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43111	18041-20001-34805	5670 W WILSHIRE BLVD STE. 1500	90036	4	135B181   931	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM			PC Approved	10/31/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	10/31/2018changes to an approved set of plans.  changes to light fixtures and energy recalculations.this is plan check only.((((Plan check for Title 24 Energy only in existing high-rise office space T.I. Total area: 13207 sqs ft. B#18016-10000-25332))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43112	19041-10002-12221	1833 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.04342	-118.37677	DELTA 7 CHANGES TO PERMITTED SET OF PLANS :TENANT LOADS ARE SUPPLIED FROM 3000A  EXISTING SECTION FROM NEW 400A PANEL  M, 200A PANEL P, AND 200A PANEL  L; LOADS ARE THE SAME; ARRANGENT LIGHTING SYSTEMNEW FUSES FORPANEL FEEDERS UPDATED ISC AT PANELS AND AIC RATING OF PANELSCHANGES ARE CLOUDED AND MARKED DELTA 7(((((((((FULL PLAN CHECK FOR POWER AND ENERGY FOR RETAIL	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43113	16041-10000-22877	915 W WILSHIRE BLVD 22nf flr	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.05069	-118.2599	CORRIDOR REVISION AND RESTROOM UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43114	10041-20001-11314	3233-3237 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035012	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM			PC Approved	10/18/2010 12:00:00 AM	ADDRESS	34.02889	-118.37311	Plan check only for revision to approved plans. The revision are emergency lighting, fixture changes, and T24 calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43115	17041-10000-15021	3530 W WILSHIRE BLVD 1600	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Info Complete	05/31/2017 12:00:00 AM	ADDRESS	34.06154	-118.30122	PC FOR ENERGY ONLY (TITLE 24). TENANT IMPROVEMENT OF OFFICE SPACE IN HIGH RISE BUILDING. TOTAL AFFECTED AREA 8787 SQ.FT.SCOPE INCLUDES LIGHTS AND RECEPTACLES WITH NEW PANEL AND CIRCUITS.***********************************UPDATE ENGINEER INFORMATION (MISSING ON THE PLAN)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43116	17041-20000-01881	2153 W KRESS ST	90046	4	151-5A173 123	5567002029	R1-1	Central	Hollywood	Bel Air - Beverly Crest	Yes	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	PIN	34.11013239	-118.3778625	PV1.  Install 10.0 kW roof mounted grid tied PV system.  Central inverter standard plan.  (40) modules with (1) 10 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43117	14041-20000-12041	12655 W SANDHILL LANE UNIT 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97753	-118.41457	pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #2. 2/3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43118	14041-20000-02112	6935 N AMESTOY AVE	91406	6	183B133   656	2230003022	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.19682	-118.50566	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8 KW AC USING 42 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43119	10041-10000-06988	14320 W AETNA ST	91401	6	177A151    91	2240007901	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	04/16/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	34.18006	-118.44473	INSTALLING 250 kva  NON EMERDENCY GENERATOR AND ATS .  ALL NON EMERGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43120	17041-10001-18656			11	156B137    57	4490006039	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			Corrections Issued	05/25/2018 12:00:00 AM	PIN	34.12635206	-118.48865436	PC FOR CHANGES TO APPROVED SET.  CHANGING  BREAKERS  FROM 200A TO 100A IN MSP AND SUBPANEL. ALSO, CHNAGES TO CONDUCTORS SIZE. THIS IS PLAN CHECK ONLY!!Installation of (1) new 200A load center with (1) 5.8 kVA  Tesla AC Powerwall battery for an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43121	19041-20000-46109	19600 W ROMAR ST	91324	12	204B117   399	2726010014	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.25446	-118.56085	PV1 PLAN CEHCK FOR 11.8 KW DC/10.6 KW AC PV SYSTEM. SCOPE OF WORK CONSISTS OF (29) PV MODULES WITH MICROINVERTERS, AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43122	17041-10000-11980	145 W 64TH ST	90003	9	105B201  1901	6005023016	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	33.98163	-118.27523	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 33900 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43123	18041-20001-08482	15000 W CORONA DEL MAR	90272	11	123B129   711	4411030007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	ADDRESS	34.03145	-118.52276	supplemental plan check only for changes to approved set. increase in circuit breaker size from 100A to 200A and showing a 175A load. clouded changes only*original*Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (3) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43124	16041-10000-26583	2005 W MERTON AVE	90041	14	162A223   155	5686003022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.13826	-118.21178	Plan check for T-24 only.  Remove outdoor HID fixtures and replace with new LED fixtures. Total affected area: 4,280sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43125	15041-10003-12882	21221 W OXNARD ST	91367	3	177B105    59	2149005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Apartment			03/06/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.17943	-118.59525	Plan check for a lost set of plan.  Applicant provides a copy of the original  approved stamp set for reference.Note: Permit has been pulled under the master application. plan check only.(((Six story mixed-use building with 379 dwelling units (including 101 Work-Live units), Building Permit 15010-10000-00387)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43126	19041-20000-41147	20815 W PINECONE CIR UNIT #17	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.29585	-118.58745	PV roof mounted system, PV system size: 4.2KW with 12 AC Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43127	15041-20001-16259	936 S OLIVE ST UNIT 356	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Master permit for 20 unit apartment. Solar clearance shall apply to address 936 Olive St. Units 246, 248, 249, 250, 252, 254, 255, 256, 257, 346, 348, 349, 350, 352, 353, 354, 355, 356 and 357. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43128	15041-10001-11997	8271 W BEVERLY BLVD	90048	5	138B173   393	5514009052	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	ADDRESS	34.07623	-118.36975	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES MARKED DELTA B.  CHANGES INCLUDE REVISIONS TO LIGHTING AND ENERGY CALCS.  TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2270.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43129	13041-10000-09622	4200 N RADFORD AVE	91604	2	165B169   370	2368001028	[Q]MR2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			Reviewed by Supervisor	05/02/2013 12:00:00 AM	ADDRESS	34.14736	-118.39192	CHANGES TO 3-STORY BROADCASTING STATION BLDG'S EMERGENCY LIFE SAFETY SYSTEM.  CHANGES TO AUTOMATIC TRANSFER SWITCHES, RELOCATION OF LOADS TO DIFFERENT ATS'S.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43130	15041-10000-38396	12038 W VENTURA BLVD	91604	2	162B165   133	2369015016	(Q)C2-1VL-RIO, (Q)P-1VL-RIO, C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.14352	-118.39381	T-24, PC for energy only to a multi use commercial site. Installing new lighting and receptacles. Sq ft = 3024WORK IS IN CONJUNCTION WITH 15041-20000-30626	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43131	18041-20000-04581	13300 N VALLEYHEART DR NORTH	91423	4	165B157   202	2360013012	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Apartment			02/07/2018 12:00:00 AM			PC Info Complete	06/19/2020 12:00:00 AM	ADDRESS	34.15152	-118.42275	800A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43132	13041-10000-01573	7402 N VARNA AVE	91605	2	186B157   348	2328029016	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Info Complete	03/21/2013 12:00:00 AM	ADDRESS	34.20486	-118.42457	Single story building Remove existing 400A 240V Service and install new 600A 277/480V Service. Adding new 400A panel. Installation of industrial machines.  No work on lighting.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43133	18041-10000-18788	307 E 22ND ST 2ND FLR	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	33.72712	-118.27383	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES ON THE 2ND FLOOR. 6163 SQFT. BUILDING PERMIT # 18016-10000-12654	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43134	19041-10000-46720	619 E 116TH PL	90059	15	084B205   262	6084001028	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	33.92837	-118.26448	PV1, NEW ROOFTOP MOUNTED SOLAR SYSTEM, SYSTEM SIZE IS 3KWac/2.4KWdc. SCOPE OF WORK IS EIGHT MODULES (CANDIAN SOLAR) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE3000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43135	14041-10001-04944	17007 W BOLLINGER DR	90272	11	126B121   197	4419016015	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.04378	-118.54917	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.[{PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(17) MODULES: CANADIAN SOLAR CS6P-250PX}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43136	10041-20001-19832	320 S LA BREA AVE	90036	4	135B181   238	5507008023	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.06822	-118.34383	REVISION TO APPROVED PLANS. CHANGES ON T24 CALCULATIONS AND FIXTURE TYPES. PLAN CHECK T24 ENERGY FOR GENERAL/EMERGENCY LIGHTING FOR CHANGE OF USE FROM RETAIL TO RESTAURANT. PERMIT TO INCLUDE ADDITIONAL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43137	19041-10000-19372	2476 E HUNTER ST	90021	14	121-5A219  79	5168030001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Issued	08/02/2019 12:00:00 AM	ADDRESS	34.02749	-118.22728	UPGRADE WAREHOUSE SERVICE TO 800A. SCOPE INCLUDES NEW 800A PULL SECTION  AND DISTRIBUTION BOARD. No changes to lighting or power plans.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43138	17041-10000-40632	12010 W CARL ST	91342	7	213B165    95	2531008052	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.28404	-118.39426	PC FOR ROOFMOUNTED PV ON SFD. SYSTEM SIZE 5.8KWDC/ 6.0 KWACSCOPE INCLUDES 20 MODULES WITH CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43139	14041-20000-00763	1351 S KENISTON AVE	90019	10	129B185   717	5083022011	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.04986	-118.33925	New rooftop PV system for an existing single family dwelling using Enphase M215 Microinverters and 100 amp service upgrade.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43140	18041-10000-30243	400 S VERMONT AVE	90020	13	135B197   508	5077003033	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.06665	-118.29145	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43141	15041-10000-03539	9182 N KELVIN AVE	91311	12	198B109   125	2748036008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.23802	-118.58526	T24 FOR RETROFIR EXISTING LIGHTS TO LED WITH RETROFIT KITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43142	19041-30000-01748	1700 S LINCOLN BLVD	90291	11	111B149  1302	4242010031	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	33.99682	-118.45798	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 2,400 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43143	13041-20000-20379	1726 W 7TH ST 1726-1730	90017	1	132A205   302	5142014001	C2-2	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.05462	-118.27309	lighting AND POWER  for 5 tenant lease spaces. work done in units A,B,C,D,E, AND H. TOTAL AREA  SQFT. OWNER WILL PROVIDE THE BUILDOUT FOR ALL THE UNITS. PC FOR POWER AND ENERGY. TAKEN AS FIRST TIME TENANTS. PC INCLUDES CHAGES TOAPPROVED SET TO ADD T24 CALCULATION AND NEW LOAD FOR NEW SERVICE. PERVIOUS SET UNDER APPLICATION # 12041-20000-27919	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43144	13041-10001-25768	505 S VIRGIL AVE ste 104	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			Corrections Issued	11/18/2013 12:00:00 AM	ADDRESS	34.0649	-118.28724	Surgical operation will be performed in tenant space and is a healthcare facility per NEC.  Additional plan check for power.  (((TITLE-24 ONLY; WORK IS FOR INTERIOR TENANT IMPROVEMENT FOR DOCTOR'S OFFICE, IN STE 104. NO SURGICAL OPERATION WILL BE DONE IN THE DOCTOR'S OFFICE PER APPLICANT. TOTAL AREA IS 1970 SF. PERMIT TO BE PULLED @ THE ELECTRICAL PLAN CHECK COUNTER 5)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43145	15041-10000-11352	907 E 3RD ST	90012	14	129A215   266	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			PC Info Complete	07/02/2015 12:00:00 AM	PIN	34.0461867	-118.23487077	PC FOR POWER AND ENERGY. CHANGE OF USE FROM MANUFACTURING TO GALLERY. ADDITION 1000A TO EXISTIN 1200A SERVICE. TOTAL AREA(CONDITIONED AND UNCONDITIONED) 116005 SQ FT. PHASE 2 OF PROJECT WITH APP# 14041-10000-33875.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43146	18041-10000-45024	4201 W WILSHIRE BLVD	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.06189	-118.31911	pc only for T-24 for lobby and elevator in existing High rise building. total effected area is 1845sf,6th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43147	14041-10001-11742	412 E BOYD ST	90013	14	129A213   335	5147006002	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM			PC Approved	08/13/2014 12:00:00 AM	ADDRESS	34.04622	-118.24229	(((8/13/2014 Supp. app. at request of inspector to approve the removal of time clock and addition of two recepticles.)))Replace of FC and HVAC units with load exceed 400A.  New lighting in common areas.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43148	16041-10000-44666	3716 N BARHAM BLVD Building B	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.14107	-118.34149	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS.THIS PC IS FOR BUILDING B"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43149	14041-10000-34985	6060 W WILSHIRE BLVD	90036	4	135B177   526	5086009014	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.06273	-118.36103	Plan check for power and title 24.  Renovation to gallery spaces and restrooms in existing museum. New lighting and panels are being installed.  Also 20 panels are being replaced in kind but are denoted as existing on the plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43150	12041-10000-19376	1537 N NORFOLK ST	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	07/23/2013 12:00:00 AM		Issued	07/23/2013 12:00:00 AM	ADDRESS	34.06138	-118.20223	PLAN CHECK FOR USC DOHENY EYE INSTITUTE 3000A SWITCHBOARD AND 600A DISTRIBUTION BOARD REPLACEMENT. NO CHANGE IN LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43151	15041-10002-12246	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	PIN	33.93847109	-118.41935625	REVISIONS TO LIGHTING SYSTEM: AREA INCREASED BY 2800SF WITH ADDED LUMINAIRES IN THE NEW AREA; A LIGHTING CONTROL SYSYTEM AND DEMAND RESPONSE SYSTEM ADDED PLAN CHK IS FOR INCREASED AREA TITLE 24 COMPLIANCE(((((((((TI FOR TITLE 24 TO AN (E) OFFICE SPACE FOR 3 FLOORS. PC FOR ENERGY. TOTAL SQ. FT. 11386.ALL LIGHTING CIRCUITS ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43152	08041-10001-16406	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Public Safety Only			01/07/2010 12:00:00 AM			PC Approved	01/07/2010 12:00:00 AM	ADDRESS	34.10686	-118.33085	Plan check only.  Per inspector request to recheck plans. ------Plan check for new installation of fire alarm system in a existing 6 story mixed use building.  Work will be on first floor commercial and in common areas of residential, will not require tenant to move out.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43153	16041-10000-05099	1223 W 59TH PL	90044	9	105B197   203	6003010022	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	33.98681	-118.29673	PV1, INSTALL NEW 3.00 KW DC ROOF-MOUNTED SOLAR ARRAY ON  A SINGLE FAMILY HOUSE.(12) MODULES: SOLARWORLD SW 250 POLY(1) INVERTER: SOLAREDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43154	13041-10000-20610	11111 W SANTA MONICA BLVD SUITE 1070	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/13/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	TITLE 24 PLAN CHECK ONLY. PERMIT TO BE PULLED AT THE ELECTRICAL PLAN CHECK COUNTER. 3486.8 SQFT. EMERGENCY LIGHTING. HIGH RISE. 21 FLOORS. WORK ON SUITE 1070.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43155	15041-20000-19988	16830 W VENTURA BLVD Suite G	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check for Title 24 only. Project site is an existing commercial building (Suite G). Project scope is a tenant improvement. Total lighting area = 1,276 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43156	14041-20000-17552	16633 W VENTURA BLVD # 550	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.15823	-118.49571	TENANT IMPROVEMENT TO AN (E) OFFICE. new lighting. pc for T24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43157	19041-10000-53804	1413 W PACIFIC COAST HWY	90710	15	033B193    38	7410009041	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Issued	12/31/2019 12:00:00 AM	ADDRESS	33.78962	-118.30167	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY.OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43158	18041-10000-25556	14526 W SHERMAN WAY	91405	6	183B149    64	2219008013	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.20103	-118.44977	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43159	19041-10000-16957	1140 S CRENSHAW BLVD	90019	10	129B189   393	5081002001	C2-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.05162	-118.32436	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43160	14041-20000-16157	3151 N FARNSWORTH AVE	90032	14	141A237    32	5220009025	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Expired	08/01/2016 12:00:00 AM	ADDRESS	34.08238	-118.16571	9KW PV1 roof-mounted system with (40) SMX 250 Solar Panel modules and (2) Sunny Boy 5000TL-US inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43161	18041-20000-10380	20666 W WALNUT CIR	91326	12	219B109   358	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29432	-118.58449	PV1.  Install 3.84 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43162	11041-10000-13551	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	REPLACEMENT OF SWITCHBOARDS ON EXISTING COMMERCIAL BUILDING AT PARAMOUNT STUDIOS.  PLAN CHECK IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43163	11041-10000-11090	3560 W MARTIN LUTHER KING, JR BLVD Space FC2	90008	10	114B185   217	5024009013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM			PC Approved	05/31/2011 12:00:00 AM	ADDRESS	34.01077	-118.33473	T.I.  Existing restaraunt space remodel.  Adding and replacing light fixtures.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43164	12041-10000-08178	15248 W TUPPER ST	91343	7	198B145   227	2656024008	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Expired	05/16/2014 12:00:00 AM	ADDRESS	34.23903	-118.46488	New 8.6kw rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43165	17041-10000-16680	13100 W VAN NUYS BLVD	91331	7	210B161   759	2534018014	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Issued	05/18/2017 12:00:00 AM	ADDRESS	34.26869	-118.41823	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 8500 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43166	17041-10000-32372	555 W 5TH ST 30&31ST FL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC for T24 only for office TI. Total load under 400A. Installingnew lights, receptcales, two new panels, 45KVA XFRM and equipment. Total area of 28905sqft. Building 17016-10000-17240	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43167	15041-10000-19835	2300 E PACIFIC COAST HWY	90744	15	033B217     3	7428008905	M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	33.79043	-118.22853	Power plan check only. Project is dedicated for Phase-2 work upgrading back up system  with selective existing load, and connecting  the Vaperizer equipment located in METHANE ZONE.  Scope of work is mainly connecting existing selective load, all new equipment MCCE1 , MCCE2 and MCC3 that are setting on the foundation of Phase-1 work from the (2) new generators. Reference for Phase-1 permit #: 15041-10000-04621 and 15041-10000-08389	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43168	11041-10001-20653	1016-1026 E ELKGROVE AVE BLDG 7	90291	11	111B145   666	4243002069	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/26/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.00059	-118.45915	LINCOLN PLACE APARTMENT PROJECT  Addition of  three E.V at 1560 va and a 200 amps panel and meter is added to existing section.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43169	19041-20000-42526	1801 S CENTURY PARK EAST Ste. 2010	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.06201	-118.41537	Tenant improvement add new lights plan check for title-24 only total affected area 4092 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43170	10041-10000-13896	1200 S CLUB VIEW DR #14 North	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			07/20/2010 12:00:00 AM			PC Info Complete	09/23/2010 12:00:00 AM	ADDRESS	34.06748	-118.42481	First Time Occupancy in a Hi-Rise Residential building. Suite # 14 North.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43171	19041-10000-04935	1020 N VERMONT AVE	90029	13	144B197   761	5539003024	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	08/22/2021 12:00:00 AM	ADDRESS	34.09057	-118.2915	New Fire Alarm system  in a theater. Total area is 10,590 SQ FT. (1) FACP, (50) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43172	19041-20000-13635	19419-19421 W ENADIA WAY	91335	3	183B117   117	2130026019	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.20027	-118.55625	ROOFTOP INSTALLATION ON EXISTING SFD TO FEED DETACHED ADU. SYSTEM SIZE IS 2.17KW DC/1.68KW AC/1.93KW AC CEC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES 310W AND (7) ENPHASE IQ 6 MICROINVERTERS 240W.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43173	18041-10000-16194	23115 W SHERMAN PL	91307	12	183B097    55	2021014044	CR-1VL, P-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	05/07/2018 12:00:00 AM		Issued	05/07/2018 12:00:00 AM	ADDRESS	34.20115	-118.63061	fire warning system with central station monitoring for single story medical imaging center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43174	12041-10001-22730	500 W WORLD WAY Delta-Term 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/29/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	CHANGES TO PERMITTED SET  OF PLANS. ORIGINAL SET OF PLANS INCLUDED NEW DISTRIBUTION BOARDS AND LOADS THAT WERE THE RESPONSIBILITY OF THE LANDLORD-LAWA. THESE ARE NOW SHOWN TO BE EXISTING AND TENANT DELTA LOADS ARE SUPPLIED FROM TENANT DISTRIBUTION BOARDS((((((((((((Renovation at the Delta offices at Terminal 5 at LAWA. Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43175	14041-10000-01231	1458 S SAN PEDRO ST # 154	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK IS INDOORS. 720 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43176	15041-10000-22267	4934 N LA RODA AVE	90041	14	160-5A225  13	5689005012	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/15/2015 12:00:00 AM	ADDRESS	34.13626	-118.20507	PV1. INSTALL 8.48 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: KYOCERA KU2606CPA(1) INVERTER: FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43177	19041-20000-00790	515 S FLOWER ST Ste. 1357	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 only for T.I. office conference room high-rise building. Total area: 250 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43178	16041-20000-31942	8353 N BRIMFIELD AVE	91402	6	192B145   314	2653022***	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.06	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.22314	-118.45934	Install 5 kW ungrounded AC roof mounted utility interactive PV system for SFD.  Central string inverter standard plan.  (18) 280W modules with (1) 5 kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43179	16041-20001-21184	10359 W DIAMOND ST LOT 2	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43180	13041-10000-30595	12746 W JEFFERSON BLVD	90094	11	102B161  1167	4211033012		West Los Angeles				2760.00	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	9 screen Cinemark theater TI.  First time tenant from core and shell.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43181	19041-20000-49181	17426 W MANTECA ST	91406	6	186B129   924	2228011005	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.20463	-118.51257	PV1 PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 3.6 KW DC/3.8 KW AC. ESS SIZE IS 9.6 KWH. SCOPE OF WORK CONSISTS OF (10) PV MODULES WITH A 3.8 KW INVERTER, A 5 KW AUTO TRANSFORMER, A BATTERY, AND A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43182	16041-10000-04410	1245 W WILSHIRE BLVD suite 690	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	FIRST GENERATION 4,100 SF MEDICAL OFFICE TI WITHIN EXISTING MEDICAL OFFICE BLDG SUITE #690. PC FOR ENERGY USING PERFORMANCE METHOD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43183	15041-10000-33961	6147 E OUTLOOK AVE	90042	1	154-5A229 352	5484026040	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.11602	-118.18835	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.STANDARD PLAN CENTRAL STRING INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43184	12041-10000-10207	845 S FIGUEROA ST	90017	9	129A207   195	5144022036	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	06/07/2012 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	34.04698	-118.26234	This is a five story bldng, core and shell, no lighting, low rise. existing conduits, plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43185	19041-10000-29894	3231 S PHILO ST	90064	5	123B161   698	4316019007	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.03258	-118.40797	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.90KWdc / 9.50KWac.  SYSTEM CONSISTING OF 33 MODULES USING MICROINVERTERS(IQ6-60-2-US) CONNECTED TO EXISTING 400A SERVICE.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43186	11041-20001-13095	1115-1129 S ALVARADO ST	90006	1	129A201    14	5136018902	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Approved	01/10/2013 12:00:00 AM	ADDRESS	34.04969	-118.28139	Modification delta 8 to previously approved plans.  DWP methane section to be installed ahead of the service equipment.  Plan check for power for two relocated historical buildings with a common basement and connecting tunnel. Existing permit for a new 600A service, panels, ckts, and equipment.  The electrical engineer indicated that the common basement creates one building out of the two historical buildings.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43187	13041-20000-17236	5272 W LOS ENCANTOS WAY	90027	4	151-5A195  37	5588037014	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Issued	07/22/2013 12:00:00 AM	ADDRESS	34.111	-118.30578	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.8 KW USING SOLAR EDGE TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. TOTAL OF 32 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43188	17041-20000-37554	9301 N WINNETKA AVE B	91311	12	198B113   122	2748038032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Issued	10/18/2017 12:00:00 AM	ADDRESS	34.23934	-118.57134	Plan check for energy only. Changing lights in commercial garage to LED. Adding emergency lighting inverter. T24 area - 66,405sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43189	14041-20000-05719	17513 W BULLOCK ST	91316	5	177B129   449	2254033001	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.17978	-118.51463	Roof mounted PV system with Optimizer and with transformerless inverters.  System size 5.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43190	15041-20000-31060	3200 W ADAMS BLVD	90018	10	123B189   714	5052015032	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM			Corrections Issued	09/18/2015 12:00:00 AM	ADDRESS	34.03243	-118.31875	Plan check for power and energy existing space multi-purpose. Total area: 9,080 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43191	10041-20000-10156	701 W EXPOSITION BLVD	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	07/26/2010 12:00:00 AM	ADDRESS	34.01842	-118.2857	Plan check T-24 Energy (general/emergency) lighting for office TI in Hoffman Hall Suite #103, 300 at USC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43192	14041-20000-06548	14300 W BEAVER ST	91342	7	219B153   274	2507024005	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.29738	-118.44473	PV1 ROOFTOP TRANSFORMERLESS SYSTEM WITH SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43193	16041-10000-41992	10250 W CONSTELLATION BLVD 1st-3rd FL	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for power and energy for an existing high-rise building; scope includes the  2nd and 3rd complete floor T.I.  and  Partial 1st floor T.I.(A-occupancy). Newly connected Load over 400A. Total area: 44,472  sq ftB# 16016-10000-28583	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43194	19041-20000-13858	11669 W SANTA MONICA BLVD	90025	11	126B149   234	4262002017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	07/31/2020 12:00:00 AM	ADDRESS	34.04409	-118.45575	Power and lighting for medical office TI.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43195	16041-10000-25310	2884 S MCCONNELL DR	90064	5	126B165   939	4308016014	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.03876	-118.40178	PV1, NEW 5.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, WITH P6 V BATTERY BACK UP.(18) MODULES: SUNIVA OPT280-60-4-1B0(1) INVERTER: MAGNUM MS4024PAE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43196	16041-10000-23684	1100 S HOPE ST C1	90015	14	127-5A207 333	5139005***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Issued	09/23/2016 12:00:00 AM	ADDRESS	34.04195	-118.2631	PC for energy only to a commercial bulding. Change of use from retail to restaurant. Adding new lighting and power. Installing 3 new panels, newly connected load is less than 400 amps. Total sqft = 1725	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43197	12041-20001-24310	9080 W PICO BLVD 1st floor	90035	5	132B169   884	4305001020	C4-1VL-O, R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Approved	11/09/2012 12:00:00 AM	ADDRESS	34.05508	-118.38965	Plan check for revision to interior lighting system.  No major change.  See delta A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43198	17041-10000-20404	6469 W NANCY ST	90045	11	102B165    73	4110017016	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	33.97866	-118.40044	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE(4.7KVA). CONSISTING OF (16) AC MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43199	18041-10000-01810	10036 N ILEX AVE	91331	7	204B161   708	2624001001	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2018 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.25266	-118.40943	Plan check for PV roof mounted system. PV system size: 6.0kW with 34 modules and 1 inverter(6.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43200	09041-10002-11196	10380 W WILSHIRE BLVD PENTHOUSE-#2102	90024	5	135B157   141	4327013***	[Q]R5-3	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			11/07/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.06719	-118.4277	REVIEW OF CHANGES TO THE PLANS FOR THE PENTHOUSE (2 FLOORS) OF A HIGH RISE CONDO BUILDING UNDER CONSTRUCTION. NEW CIRCUITS AND NEW LUTRON LIGHTING CONTROL PANELS WERE ADDED- INCREASING THE CONNECTED LOAD TO THE 800A DISTRIBUTION BOARDNOTE THAT PLAN CHK FEE IS APPROXIMATE((((((((((DELTA 1 REVISIONS TO approved plans with PCIS #07041-20000-30469 (Tenant buildout and new electrical for existing penthouse).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43201	16041-20000-04899	1285 W 35TH PL	90007	8	120B197   803	5040020008	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.02379	-118.29717	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derating main to 150A (center fed panel). System size: 5kW. Ungrounded system. (18) 285W pv modules. Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43202	17041-20000-29153	8534 N MARKLEIN AVE	91343	6	192B145   136	2654019007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.22557	-118.47082	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 4.2 kWac and consists of (1) inverter, (18) modules, (1) 5 kWac Powerwall, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43203	17041-10000-36179	10250 W SANTA MONICA BLVD STE. 2680	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for ""GLOVEWORX"" Ste. 2680 at Westfield Century City.  Install new electrical equipments,  total affected area: 2,856 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43204	15041-10001-06514	1050 N VINE ST	90038	13	144B189   743	5534022032	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			Corrections Issued	04/22/2015 12:00:00 AM	ADDRESS	34.08996	-118.32643	Change to an approved set by adding and removing lighting on the floor plan; all changes are under delta-1 only.(((PLAN CHECK FOR ENERGY ONLY FOR TI TO EXISTING RESTAURANT SPACE. NOT A FIRST TIME TENANT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43205	19041-10002-03533	8148 N DE GARMO AVE	91352	2	192B177   953	2407022011	RD2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Apartment			04/02/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.21847	-118.35681	CHANGE BUILDING FROM RESIDENTIAL TO 4 UNIT APARTMENT (APARTMENTS 8148, 8150, 8152, 8154)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43206	11041-20000-14737	6440 N SEPULVEDA BLVD suite# Q	91411	6	180B145   596	2235001022	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.1877	-118.46585	Replace a 600 Amp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43207	16041-10000-43684	2708 E MARENGO ST	90033	14	132A227   312	5177004033	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.05446	-118.19728	INSTALL NEW 7.71 KW AC/7.22 KW D ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(23) MICRO INVERTERS: SUNPOWER SPR-X21-335	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43208	14041-20000-05691	3880 E SAN RAFAEL AVE	90065	1	148-5A221  25	5465001004	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Issued	05/05/2014 12:00:00 AM	ADDRESS	34.10212	-118.21724	ADDITION OF AIR CONDITION, NEW SERVICE, AND CHANGES TO LIFE SAFETY BRANCH ON GENERATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43209	12041-10000-17121	500 S VIRGIL AVE	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM			Reviewed by Supervisor	08/08/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Plan check power and energy for medical office suite #204	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43210	16041-10000-36087	8875 N GLENOAKS BLVD	91352	6	195B173   309	2408008034	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.23024	-118.36714	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 24650 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43211	17041-20000-02601	15301 W VENTURA BLVD Suites 200-230	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for Title 24 only. Project site is two suites in an existing commercial building. Project scope is turning one suite into two/tenant improvement. Total lighting area = 4,647 sq. ft.Note: Building permit has been pulled under 17016-10000-00496	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43212	18041-10000-14392	3600 W WILSHIRE BLVD #2200	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.06156	-118.30335	PC FOR T-24 FOR OFFICE TI IN A HIGH RIZE. SCOPE INCLUDES NEW CIRCUITS, LIGHTS AND RECEPTICALS. TOTAL  AFFECTED AREA IS 2970SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43213	14041-10001-02537	9672 N LARAMIE AVE PV1	91311	12	201B113   666	2748027001	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	04/09/2014 12:00:00 AM	ADDRESS	34.24591	-118.57345	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.  (((5.8 KW DC ROOF MOUNT PV, (24) MODULES, (1) TRANSFORMERLESS INVERTER (POWERONE PVI-5000-OUTD-US).  MODULES: TALESUN SOLAR TP660P-B-240)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43214	17041-20000-30293	18765 W FAIRFIELD ROAD	91326	12	207B121   627	2728029044	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.26205	-118.54171	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.76KW.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43215	15041-10000-11634	1100 S HILL ST BLDG 11H	90015	14	126A209   128	5139019034	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			04/20/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.03989	-118.25984	NEW METHANE MITIGATION SYSTEM LEVEL 5. Fire department approval on separate plans. Changes on plans include update of battery calculations and clarifications with wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43216	16041-20001-19401	3239 N PASADENA AVE Unit B	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	RSES expedited plan check per applicant request.  PV2.  Install 5.7 kW DC roof mounted PV system.  (20) modules with (1) 5 kW transformerless inverter with power optimizers.  2 of 3 PV systems proposed for property submitted concurrently.Zoning clearance obtained under 16041-20000-19398	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43217	19041-10000-26648	1425 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   322	5036031035	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			07/11/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	34.01101	-118.30077	PLAN CHECK ONLY.. TENANT IMPROVEMENT ON EXISTING RESTAURANT INCLUDING. INSTALLING NEW LIGHTS.  T-24 ENERGY ONLY.PERMIT NUMBER: 19041-10000-25922BUILDING PERMIT: 19016-10000-07438	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43218	14041-10000-06480	9241 N RESEDA BLVD	91324	12	198B125   220	2763009038	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.23836	-118.53628	Change of use for tenant space from office to medical office - dentist office.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43219	14041-10000-17163	4150 S GLENCOE AVE	90292	11	108B153  1207	4230006008	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Info Complete	09/29/2014 12:00:00 AM	ADDRESS	33.98875	-118.44156	TI in one story warehouse conversion to office. Entail existing services, power, new panels, lighting, and title 24 energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43220	17041-10001-27782	10250 W SANTA MONICA BLVD # 2700	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to an approved set of plans. All changes are made under delta 3. Changes include revising feeder conductors to reflect as built. Revising feeder due to voltage drop. Note: Permit is paid under PCIS#17041-10000-27782	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43221	14041-10000-16252	1149 S HILL ST 5TH FLOOR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Expired	08/03/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES ON 5TH FLOOR. NOT A PATIENT CARE AREA PER APPLICANT. 5270 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43222	12041-20000-10698	5340 S ALLA ROAD	90066	11	102B157    39	4211008023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	33.9773	-118.42567	S.103 OFFICE T.I.ENERGY, EMERGENCY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43223	15041-20000-13692	13220-13230 W VAN NUYS BLVD	91331	7	207B157   226	2535021005	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.26679	-118.4208	Plan check for power and Title-24.  Total area = 16,417 sq. ft. (indoor) and 26,021 sq. ft. (outdoor)  Construction of new retail auto parts shop.  New 800 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43224	19041-10000-50717	1505 N SORRENTO DR	90272	11	132B133   180	4425021017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	02/04/2020 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.05778	-118.50349	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 36  (SUN POWER A400) AC MODULES,  36 MICRO-INVERTERS (SPWR-A4), CONNECTED TO A NEW 400A MAIN SERVICE PANEL. SYSTEM SIZE: 14.40KW DC, 12.56KW AC. Fees $98.15 Due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43225	19041-10000-50135	9725 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	04/21/2020 12:00:00 AM		Permit Finaled	11/12/2020 12:00:00 AM	ADDRESS	34.24687	-118.5363	TITLE 24 ENERGY PLAN CHECK. REMOVING OLD LIGHTING AND REPLACING IT WITH NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43226	17041-20001-01880	1233 S NORTON AVE	90019	10	129B189   811	5081007021	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Apartment			01/19/2017 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.04852	-118.3238	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnecting with individual unit's 100A MSP. 3.8kW ungrounded system. (15) 300W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43227	17041-20000-18896	649 S WALL ST	90014	14	127-5A211 227	5148023018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	12/31/2020 12:00:00 AM	ADDRESS	34.04256	-118.24822	Plan check for power and energy. Project site is a new 7-story building: 5 levels of residential and medical office over 2 levels of podium medical office and parking. Project scope is the tenant improvement of the medical offices. Total lighting area = 31,905 sq. ft.Note: Building application has been generated under 16016-10000-20807	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43228	19041-10001-33227	12822 W HIGHWOOD ST	90049	11	132B137   328	4406009022	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM			Reviewed by Supervisor	09/04/2019 12:00:00 AM	ADDRESS	34.05822	-118.48971	***EXPEDITE FEE*** NEW ROOF MOUNTED 29.5KW PV SYSTEM WITH 82 PV PANELS AND OPTIMIZER AND 3 CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43229	19041-10000-20459	12105 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	33.98095	-118.40764	PC FOR T24, ENERGY ONLY. FOR INDOOR LIGHTING AND CONTROLS IN CULINARY STAGEING AREA TOTOL AFFECTED AREA 388 SQ. FTSCOPE INCLUDES NEW LIGHTS AND RECEPTACLES WITH CIRCUITS AND EQUIPMENT. B#19016-10000-05422	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43230	13041-20000-26279	18318 W VANOWEN ST	91335	3	180B125    42	2125016018	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.19366	-118.53225	PC FOR T24 ENERGY ONLY. RENOVATION OF LIGHTING IN DELI AREA AND OTHER SMALL AREAS. NEW LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43231	12041-10000-09685	2950 S VAN BUREN PL	90007	8	120B197   279	5054014022	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Apartment			04/27/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Expired	10/16/2014 12:00:00 AM	ADDRESS	34.02777	-118.29685	PLAN CHECK FOR NEW 18.24 KW PV SYSTEM ON THE ROOF OF AN APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43232	18041-10000-03862	9714 N MASON AVE	91311	12	201B109   213	2748012054	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Closed	09/16/2019 12:00:00 AM	ADDRESS	34.2468	-118.57963	PC for new (2)Tesla Powerwall2(11.6KW) in a single family. Scope includes new load subpanel and derating to  150A breaker. Note existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43233	17041-20001-09226	12601 W PIERCE ST 1, 2, 12	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 1, 2, and 12).11kW ungrounded system. (22) AP Systems YC500i microinverters. (44) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43234	15041-10000-16522	13453 N DRONFIELD AVE	91342	7	225B149    76	2504003009	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.31663	-118.44893	MAIN SERVICE PANEL  UPGRADE TO 200AMP REFER TO 14041-20000-28396 SOLAR	N	N	Express Permit	06/10/2024 12:00:00 AM
43235	10041-10000-04039	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	33.94373	-118.40888	Provide new exist signs and emergency lighting for temporary  exit ways and corridors for LAX - TBIT, 9 until construction of new exitways and stairways additional stairway at exiting concourses as on building plan check number 10016-10000-03915.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43236	13041-10000-23061	11431 N LEMONCREST AVE	91342	7	213B177   177	2529008013	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.27728	-118.35734	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. MICROINVERTER SYSTEM ON A NON STANDARD PLAN. [MODULES: TRINA SOLAR # TSM-250PA05.08 |||| INVERTER: ENPHASE ENERGY # ENPAHSE M215-60-2LL-S22] SYSTEM SIZE IS 7.095 KW AC AND 8.25 KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43237	19041-20000-18231	21860 W BURBANK BLVD Suite 300	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.17198	-118.60379	Plan check for title 24 only in existing space Tenant Improvement in elevator lobby and reception area on third floor. Total area: 873 sq ft B#19016-30000-07720	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43238	16041-20000-41562	4910 E HUNTINGTON DR SOUTH	90032	14	142-5A233  11	5218008029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.08668	-118.17628	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 58,104 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43239	13041-10000-35566	1937 N GRAMERCY PL	90068	4	150A193    72	5587019009	R1-1D-HPOZ	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.10641	-118.31271	PV1, Install 2.65 kW DC roof-mounted solar array for a 3 story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (10) modules: Suniva OPT265-60-4-1B0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43240	14041-10000-05318	1020 S FEDORA ST	90006	1	129B197   325	5078015021	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.0522	-118.29776	NEW 4 STORY  TYPE VA  86 UNITS  ( 2 DWELLING UNITS & 84 GUEST UNITS)  HOTEL OVER  TYPE IA PARKING STRUCTURE (2 LEVELS OF SUBTERRANEAN PARKING AND ONE LEVEL ABOVE GRADE PARKING WITH OFFICE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43241	16041-10002-15170	12077 W VENTURA PL	91604	2	165B165  1214	2368002013	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.14493	-118.39507	08/26/16Changes to an approved set of plans. All changes are made under delta 1. Changes include removing/adding new lights on floor plans, relocating switchbank, and revising title 24 forms.Note: original application is under PCIS#16041-10000-15170(((07/14/16Changes to an approved set of plans. Changes include adding a switch bank for restaurant lights and replacing the occupancy sensors with time clock. No changes to the number of lighting fixtures. Note: Original application is under PCIS#16041-10000-15170(((((T24 - CHANGE OF USE TO A TAKE OUT RESTAURANT. SCOPE OF WORK INCLUDES NEW INDOOR AND OUTDOOR LIGHTING AND RECEPTECALS. TOTAL SQFT 650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43242	14041-20000-29873	5670 W WILSHIRE BLVD # 600, 620	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI TO AN EXISTING HIGH RISE BUILDING. ADDING LIGHTING TO EXISTING POWER EQUIPMENT. WORK TO BE PREFORMED IN SUITE 600 AND 620 ON THE 6TH FLOOR. 2294 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43243	13041-10001-29506	5706 N MURIETTA AVE	91401	2	174B153   525	2246018020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.17418	-118.43874	Expedited RSES plan check per applicant request. ((((PV1.  Install 5.75 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE6000A-US.  23 modules: HANAWHA # HSL60P6-PB-4-250TW.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43244	19041-10000-47896	5518 W GEER AVE	90016	10	123B177  1509	5048024005	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.03025	-118.36418	Plan Check for PV system, system size 4.160KW, 13 Canadian solar CS6K-310MS Modules with P320 solar Edge optimizers and SE3800H-US solarEdge inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43245	19041-10002-30307	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Issued	12/10/2019 12:00:00 AM	ADDRESS	33.98076	-118.40716	PC FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES THE ADDITION OF FIRE ALARM DEVICES. CHANGES UNDER DELTA 5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43246	17041-20000-35049	555 S MATEO ST Bldg 2 & 3	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.03943	-118.23302	Plan check for power and energy. Initial TI to ground level empty tenant spaces in new commercial building - install subpanels, lighting, hvac, and receptacles. T24 area - 19,700sqft.Note: Building application has been generated under 17016-10000-19507	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43247	19041-10000-03876	7507 N SIMPSON AVE Bld-#D	91605	2	186B169   490	2317010001	R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			01/31/2019 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	34.20677	-118.3893	Energy plan check for outdoor T.I . Scope includes new panels replacement and new lighting with a total area 24,505-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43248	10041-20000-14747	1020 N NAPOLI DR	90272	11	129B133   355	4408008011	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.0462	-118.50561	Plan check new single family dwelling with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43249	18041-10000-14534	16233 W VANOWEN ST	91406	6	183B137   268	2224001901	M1-1, [Q]M1-1, [Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.19405	-118.48697	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43250	11041-20000-05758	5250 N LANKERSHIM BLVD 7TH  FLR-lob/corrdr	91601	4	171B173  1421	2350018090	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.16668	-118.37545	PLAN CHECK T24 ENERGY/EMERGENCY FOR TENANT IMPROVEMENT ON THE 7TH FLOOR ELEVATOR LOBBY AND CORRIDOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43251	10041-20000-05774	11150 W SANTA MONICA BLVD 100	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	225KVA Transformer and 600A panel for future tenantexist. permit 10041-9000-01147 ( 225 KVA transformer ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43252	12041-10000-05261	2515 S CENTRAL AVE	90011	9	118-5A209 348	5131026029	C2-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	ADDRESS	34.0193	-118.25496	T.I. to an existing single story office space.  PLAN CHECK ONLY for Energy, NO Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43253	17041-10000-06403	4169 W GARDEN AVE	90039	13	157-5A205  25	5594024022	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.12781	-118.26972	Plan check for PV roof mounted system. System size: 6.4kW with 20 AC Modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43254	11041-10000-03900	17312 W VENTURA BLVD	91316	5	168B133    18	2290001002	QC4-1VL, QP-1VL	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/07/2011 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	34.16077	-118.51054	TI IN AN EXISTING RESTAURANT. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43255	19041-20001-12253	6935 N MURIETTA AVE	91405	2	183B153   764	2216013005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.19671	-118.43901	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGE TO APPROVED SET. ADDITION OF A NEW CIRCUIT BREAKER. CLOUDED CHANGE ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43256	15041-10000-18562	614 E TERMINAL WAY GATE HOUSE-BLDG	90731	15	015B205     4	7440029917	[Q]M3-1	Harbor				2961.00	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.74201	-118.26431	NEW FIRE ALARM SYSTEM IN THE PORT OF LOS ANGELES. 292 FIRE ALARM DEVICES, 2 FIRE ALARM PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43257	11041-10000-09815	1642 N WILCOX AVE	90028	13	148-5A187 203	5546007029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.101	-118.33082	T.I.  EXISTING OFFICE SPACE.  REPLACING AND RELOCATING LIGHT FIXTURES.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43258	16041-20001-34075	9601 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.24501	-118.59876	(1/18/17)changes to an approved set of plans.  changes noted delta A on floor plan.  changes affect the lighting and energy calculations.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43259	15041-10000-00405	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.03365	-118.24048	NEW 10 TIER OPEN PARKING GARAGE STRUCTURE.  PARKING BUILDING TO SERVE EXISTING ADJACENT BUILDINGS ON THE SAME PROPERTY. (APPRX. 1,405,621 SF W/ 3884 PARKING STALLS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43260	14041-10000-35521	765 W COLLEGE ST	90012	1	136-5A213 165	5406024016	RD2-1-O	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			Reviewed by Supervisor	02/05/2015 12:00:00 AM	ADDRESS	34.06621	-118.24339	Plan check for power and title 24.  Total area = 2,285 sq. ft.T.I. to existing medical office including new lighting and relocated recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43261	13041-20000-22250	13501 W CHASE ST	91331	6	195B157   264	2625034029	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.2334	-118.4266	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW USING 18 MODULES. TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43262	15041-10001-22457	10418 W PENROSE ST	91352	7	195B177   247	2404002016	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.23206	-118.35781	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 13.3KW INTERCONNECTED WITH MSP.(62) LG MONO X NEON LG265S1C-B3 MODULES(62) ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43263	14041-20000-10776	20849 W EXHIBIT PL	91367	3	177B109    26	2149012017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.17892	-118.58682	Roof mounted PV system, system size 6.75KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43264	18041-20000-35252	8810 N TAMPA AVE	91324	12	195B121   511	2784003069	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.23097	-118.55317	ti to an existing open parking lot.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43265	17041-20000-30131	17031 W GUNTHER ST	91344	12	213B133   130	2607002033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.28343	-118.50347	PV1.  Install 3.0 kW roof mounted grid tied PV system.  (11) modules with (1) SolarEdge 3kW rated string inverter.  3.0 kW system is being added to an (E) PV system.  Install 13.5 kWh rated energy storage system with automatic load control relay.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43266	16041-20000-10969	8125 N LAUREL CANYON BLVD	91605	2	189B165    66	2309028005	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.21846	-118.39672	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (28) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43267	15041-20000-08451	1562 N GOWER ST	90028	13	147A189    19	5545008020	C4-1	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	05/06/2015 12:00:00 AM	ADDRESS	34.09916	-118.32216	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 4,364 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43268	15041-20000-37493	12647 N BROMONT AVE	91340	7	219B157   150	2513022003	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Expired	12/07/2017 12:00:00 AM	ADDRESS	34.29959	-118.42484	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43269	11041-10000-26828	1536 S SELBY AVE	90024	5	132B153  1073	4325029009	[Q]RD1.5-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.05478	-118.4372	New two story school/gymnasium building.  Existing service. Plan check for power and energy. Site located in methane zone. Modification to seperate fire alarm from plan has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43270	16041-10000-14746	300 S GRAND AVE 13th-floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	PC for energy only to offices in a highrise building (13 floor). Lighting only. Total sqft =999	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43271	15041-20000-27422	5510 S LINCOLN BLVD Lobby	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	33.97299	-118.43051	Plan check Title 24 only for main entery lobby area in existing space. Total indoor area: 2,750 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43272	15041-10000-12706	6712 N LANKERSHIM BLVD	91606	2	180B169   257	2320012027	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.19257	-118.38758	T24 ONLY.  REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXUTRES. TOTAL AREA 2566 SQ FT. THERE IS TWO BUILDING TIE TOGETHER FOR PC AND THE PERMIT ON THIS IS FOR FRONT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43273	15041-20000-19697	727 W 7TH ST	90017	14	129A209   265	5144029***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.04861	-118.25837	Plan check Title 24 only for European Wax Center. Total area: 1204 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43274	13041-10000-20421	710 E 7TH ST	90021	14	126A213   305	5146032048	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	ADDRESS	34.03972	-118.24568	TITLE 24 FOR SINGLE STORY WAREHOUSE IN A FIRE-DAMAGED COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43275	19041-10000-53040	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053		West Los Angeles	WESTCHESTER - PLAYA DEL REY			2756.02	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	04/22/2020 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	33.97756	-118.41709	TITLE 24 ENERGY PLAN CHECK ONLY. TENANT IMPROVEMENT TO A CHASE BANK. ADDING NEW LIGHTING. TOTAL EFFECTIVE AREA: 3747 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43276	14041-20000-03035	8399 N SHOUP AVE	91304	12	192B101   413	2004009001	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.22254	-118.61498	pv1 single family dwelling. total system size 6kw ac using transformerless inverter nonstandard plan. using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43277	12041-10000-12635	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM			PC Approved	06/01/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	"TI IN AN EXISTING RETAIL STORE IN THE MALL.  UNIT # 109, ""CARMEN STEFFENS"".   PLAN CHECK FOR T-24 ENERGY ONLY.  PERMIT FEES ARE UNDER INSPECTION FOR NEW CIRCUITS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43278	14041-10001-05207	1724 S LIVONIA AVE	90035	5	129B169  1009	4305021005	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.04821	-118.38663	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 4.5 kW DC roof-mounted solar array on a 2-story home, interconnect with EXISTING service panel. (1)Transformerless inverter: POWER-ONE AURORA PV1-3.6-OUTD-S-US-Z-A. (18) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43279	15041-20000-09777	18851-18853 W VENTURA BLVD	91356	3	174B121   443	2160002028	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.17228	-118.54425	Plan check for Title 24 only. Project scope is a tenant improvement to an existing commercial space that has been divided into 2 spaces. Total lighting area = 4,430 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43280	13041-10000-28861	1875 S CENTURY PARK EAST #1380	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			Corrections Issued	10/16/2013 12:00:00 AM	ADDRESS	34.06115	-118.41457	TITLE 24 ENERGY PLAN CHECK ONLY. HIGH RISE. NO CHANGE IN OCCUPANCY. OFFICES. 10284 SQFT.  EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43281	12041-10002-27734	2500 S NAVY WAY Check Bldg	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			11/16/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.73363	-118.2408	Modify existing fire alarm system for Pola Maersk (port of LA) 3of 6 Check Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43282	10041-20000-13672	12980 W SHERMAN WAY	91605	2	183B161    45	2327018071	C2-1VL	South Valley	North Hollywood - Valley Village			1234.20	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	06/09/2011 12:00:00 AM	ADDRESS	34.20102	-118.4159	change of use from retail to take-out restaurant. Title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43283	18041-20000-29503	972 N RUTLAND AVE	90042	14	156A235    54	5716015002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.12348	-118.1721	PV1.  Install 6.93 kW roof mounted grid tied PV system.  (21) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43284	17041-20001-30269	21730 W DEVONSHIRE ST	91311	12	204B105   294	2747015007	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.25707	-118.60282	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on commercial building.10kW ungrounded system. (34) 380W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43285	15041-10000-14605	6430 W SUNSET BLVD STE-1050	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.09782	-118.32979	Energy plan check for an office TI located at suite-1050 of a high rise building. works includes new panel, lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43286	15041-10001-40141	13647 W VICTORY BLVD	91401	2	180B157   906	2329004021	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.18683	-118.43059	**6/13/16 Master plan is lost, this is a replacement.PC FOR NEW LIGHTING. NEW PARKING LOT. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43287	17041-10000-03160	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	33.98489	-118.42552	PC for power and energy for alterations to POD 5 for direct TV server room. PC for five new panelboards, server racks, receptacles and raceways. Total affected area is 2783 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43288	18041-10000-18599	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.06259	-118.35341	Power plan check for a 600-Amp new service relocation reconnecting to the existing load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43289	18041-10000-13366	954 S CATALINA ST 1-19	90006	10	132B197  1160	5078007024	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Apartment			04/12/2018 12:00:00 AM			Reviewed by Supervisor	05/16/2018 12:00:00 AM	ADDRESS	34.05403	-118.29462	***************SEE APPLICATION COMMENTS*************PC FOR GARAGE WORK INCLUDING AUTOMATED PARKING SYSTEM FOR POWER AND ENERGY.  SCOPE INCLUDES NEW PANEL, ATS, GENERATOR, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 4875 SQ.FT (INDOOR + OUTDOOR) B# 17010-10001-03028	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43290	18041-10000-00492	6729 N LANKERSHIM BLVD	91606	2	180B169   175	2322015020	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1232.03	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	34.193	-118.38798	REPLACE INDOOR/OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA  IS 10150 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43291	19041-10000-18601	1320 S FLOWER ST	90015	14	126A207   161	5134011018	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	02/01/2022 12:00:00 AM		Issued	02/01/2022 12:00:00 AM	ADDRESS	34.0394	-118.26703	FULL PC POWER AND ENERGY FOR NEW HOTEL (6 FLOORS, 43 GUEST ROOMS AND 2 DWELLING UNITS). SERVICE IS 2000A,120/208V,3PH,4W.   OVER FIRST FLOOR PARKING GARAGE &  WITH ROOF TOP DECK . SCOPE AREA IS 10,673SF BUILDING PERMIT: 16010-20000-05299	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43292	12041-10000-22429	17344 W KINGSBURY ST	91344	12	207B129   665	2733026003	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.26345	-118.51253	NEW 6.54 KW ROOF MOUNTED PV FOR A SINGLE FAMILY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43293	16041-10000-26580	10982 W ROEBLING AVE	90024	5	135B149   480	4363007245	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.06507	-118.44925	Plan check for T-24 only, remove indoor (exercise room) and perimeter exterior HID fixtures and replace with new LED fixtures.  Total affected area: 7,316 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43294	19041-20001-37705	5074 N CALVIN AVE	91356	3	171B117   366	2175034004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.16369	-118.55592	Revisions to approved plans.  Change from 200A MSP with 200A bus to (2) separate 100A sections on MSP.  Derating of 100A main to 80A to accomodate PV system installation.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43295	14041-20001-35059	1215 W 58TH PL	90044	9	108B197  1531	6003002016	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	12/29/2014 12:00:00 AM	ADDRESS	33.98846	-118.29644	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). Ungrounded system.24  327W pv modules across 4 strings (6+6+6+6).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43296	13041-20000-17337	1305 N COLLINGWOOD PL	90069	4	144B169    62	5560003003	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.09462	-118.38369	Full plan check for power. Single-family residence. NOT methane zone. 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43297	13041-10000-22969	21515 W VANOWEN ST SUITE 116	91303	3	183B105   934	2138011094	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.19391	-118.59942	TITLE 24 PLAN CHECK ONLY. 4 STORY OFFICE BUILDING.  WORK ON SUITE 116.    6072 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43298	15041-10000-28924	15350 W SHERMAN WAY 2nd Floor-Restrooms	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.20099	-118.46808	PC for t-24 at a commercial bldg (offices). Scope of work: adding light fixtures on 2nd floor restrooms. Sq Ft = 503.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43299	10041-10000-05654	11600 W WILSHIRE BLVD	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.05034	-118.45947	replacing a 600A distribution board ; electrical ratings of the new distribution board is the same as the old board; no changes in the loads supplied from the distribution board	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43300	16041-20000-31743	910 W FLORENCE AVE 1-20	90044	8	102B197  1185	6020001037	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Apartment			09/07/2016 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	33.9744	-118.28967	PLANCHECK FOR T24 ENERGY. LIGHTING TENANT IMPROVEMENT. 33144 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43301	17041-10000-11833	1904 S WESTWOOD BLVD	90025	5	129B153   740	4321011027	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.04812	-118.43518	NAIL SALON TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43302	16041-10000-45800	802 S FRIES AVE	90744	15	024B205    34	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	11/30/2017 12:00:00 AM		Issued	11/30/2017 12:00:00 AM	ADDRESS	33.76172	-118.26356	PC FOR POWER ONLY SCOPE OF WORK INCLUDES THE INSTALLATION OF A NEW 2500A ,480V SWITCHBOARD TO AN EXISTING 4160-480/277 TRANSFORMER. SWITCHBOARD INCLUDES EV CHARGERS UNITS WITH BUILT IN TRANSFORMERS, 2 BATTERY STORAGE UNITS AND A CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43303	14041-10001-16868	1520 N SAN PABLO ST	90033	14	135A225    64	5202004041	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.0627	-118.20276	Restamp due to original stamped set of plans lost.***** Previous Work Description *****Title 24 only.  Total area = 427 sq. ft.Install lighting and X-ray machine (100 A) in existing empty room in a healthcare facility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43304	15041-20001-18145	8508 N SHARP AVE	91352	6	192B165   230	2634040031	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.22486	-118.40184	Expedite per applicant request[[[[[Plan check for PV roof mounted system. System size: 6.0kW with 28 modules and 1 inverter (6.0kW)]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43305	15041-10000-34833	5670 W WILSHIRE BLVD 24TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	34.06222	-118.35208	T-24, TI TO THE 24TH FLOOR OF AN (E) HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES WITH EXISTING PANELS. TOTAL SQ. FT. 12854.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43306	16041-20000-29890	1307 S SANTEE ST	90015	14	124-5A209 187	5133017007	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.035	-118.25854	PLANCEHCK FOR POWER AND ENERGY. SERVICE UPGRADE AND TENANT IMPROVEMENT FOR (3) RETAIL STORES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43307	09041-10001-18648	300 S DOHENY DR 1-285	90048	5	138B169   549	4335015050	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	02/18/2010 12:00:00 AM		Permit Finaled	03/31/2010 12:00:00 AM	ADDRESS	34.07343	-118.38954	Plan check  energy for TI of restaurant on the ground floor. outdoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43308	10041-30000-03956	12121 W WILSHIRE BLVD	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM			PC Info Complete	04/22/2010 12:00:00 AM	PIN	34.04391963	-118.46825257	Plan check T-24 energy general/emergency lighting for a bank remodel located on the 1st floor of high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43309	17041-30000-38618	3704 W 3RD ST	90020	10	135B197   185	5502004008	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.06889	-118.29716	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to yogurt shop/tenant improvement. Total lighting area = 1,135 sq. ft.Note: Building application has been generated under 17016-30000-31292	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43310	18041-20003-38403	9524 N SHOSHONE AVE	91325	12	201B129   410	2755009011	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2019 12:00:00 AM			PC Approved	03/21/2019 12:00:00 AM	ADDRESS	34.24414	-118.5176	3/21/2019changes to an approved set of plans.  changes to relocate service.this is plan check only.  pv1install roof mounted pv system sized 10.3KW AC interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43311	19041-20000-24273	20606 W BLUEBIRD CT pv1	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.29691	-118.5825	pv1install roof mounted pv system sized 5.25KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43312	19041-20000-13745	5805 W 8TH ST ev2	90036	4	132B177   172	5089010024	R3-1-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			04/16/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.06086	-118.35605	addition of (11) EV chargers to an existing service.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43313	13041-20000-14695	13282 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.2 KW. USING 15 MODULES ENPHASE M215 MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43314	14041-20000-02339	10601 N DEMPSEY AVE	91344	12	207B141   556	2668010010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.26292	-118.47735	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43315	10041-10000-18262	11375 W WESTMINSTER AVE	90066	6	117B157   480	4249026280	OS-1XL	West Los Angeles	Palms - Del Rey - Mar Vista			2719.00	Electrical	Electrical	Public Safety Only			09/15/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Expired	12/10/2012 12:00:00 AM	ADDRESS	34.01603	-118.42565	installation of fire warning/monitoring of flow switches at 2 ea buildings at a well field	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43316	12041-10000-13783	6510 N CANOGA AVE	91303	3	180B105    74	2148031018	WC	North Valley				1349.02	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	PIN	34.18937539	-118.59614207	T.I. OF EXISTING RETAIL  (DSW STORE)  AT THE WARNER MARKETPLACE SPACE INCLUDING DOORS, PARTITIONS, CEILING, FIXTURES, ETC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43317	14041-20000-12697	8743 N WOODLEY AVE	91343	12	195B141   624	2688015006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.22957	-118.48531	PV1. roof-mounted system with 3kw, (12) Renesola JC250M-24 250w modules, and a 3000-OUTD-S-US TL inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43318	12041-10000-06867	175 S FAIRFAX AVE	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	05/25/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	First time tenant for a new building.  Retail space.  Plan check for Power and Energy, with Emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43319	14041-20000-20458	22050 W TULSA ST	91311	12	207B101    45	2723006011	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Expired	08/31/2016 12:00:00 AM	ADDRESS	34.26612	-118.60804	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(20) TRINA SOLAR TSM 255 MODULES(1) SOLAR EDGE SE5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43320	14041-10000-12144	13222 W SATICOY ST	91605	2	186B157   211	2303028001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.20776	-118.42104	Title 24 only - Remove HID fixtures and replace with flourescent fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43321	19041-10000-10107	850 N BROADWAY	90012	1	135A215   254	5408031013	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	PIN	34.06380239	-118.23717188	PC FOR PROPOSED INSTALLATION OF EV CHARGING STATIONS IN BANK OF AMERICA PARKING LOT.  SCOPE INCLUDES (1) NEW 1600A 480/277 3PH 4W SERVICE,(3) 150KW BTC POWER UNITS AND (3) 150 KW BTC DISPENSERS. STRUCTURAL AND ARCHITECURAL PLANS ARE SUBMITTED FOR REFERANCE ONLY.B#19020-10000-00782	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43322	17041-10000-39264	10250 W SANTA MONICA BLVD #1550 &-#S2455	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check (Power+Energy), first time tenant ""COS"" ste#1550 and its storage space ste. #S2455, total of  (7) panelboards, transfomers (2)15KVA, (1)30kVA, (1)45kVA and other motor loads. Total area under the scope:  #1550= 6670 sq.ft,  #S2455= 972 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43323	17041-10000-37694	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM			PC Info Complete	12/22/2017 12:00:00 AM	ADDRESS	34.03393	-118.22985	PC for power and energy for restuarant TI. Installing three new panels, receptacles, lights and equipment. Load exceeds 400A. Total area 6092sqft. Building# 17016-10000-28958.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43324	17041-10000-02265	21707 W NORDHOFF ST	91311	12	198B105   183	2746012040	[Q]MR2-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.23561	-118.60226	PC for indoor Tile 24 only. Remove HID fixtures and replace with new LED fixtures. Area: 14,600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43325	19041-20000-50376	230 N BARRINGTON AVE	90049	11	135B145   325	4429024006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/22/2020 12:00:00 AM	ADDRESS	34.06747	-118.47139	$0 fee per AB1414PV1 PLAN CHECK FOR NEW ROOF PV AND ESS. SYSTEM SIZE IS 15.925 KW DC/14.37 KW AC CEC. ESS SIZE IS 40.5 KWH. SCOPE OF WORK CONSISTS OF (49) PV MODULES WITH MICROINVERTERS, (3) SUB PANELS, AND (3) 13.5 KWH BATTERIES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43326	14041-10000-33784	16650 W SHERMAN WAY BLDG C	91406	6	183B137    70	2225005014	[Q]CR-1, [Q]CR-1VL, [Q]P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.2008	-118.49594	Renovation of (E) 2-story commercial office building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43327	16041-10000-36784	10250 W SANTA MONICA BLVD STE. 1640	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Cole Haan"" Ste. 1640.  Install new electrical equipments,,  total affected area: 2,220 sq.ft** New connected load is 60A to DB-ELA41"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43328	18041-10000-30038	1030 N SWARTHMORE AVE 4-104A	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	"PLAN CHECK FOR FIRST TIME TENANT - Initial tenant improvement to existing retail space ""Mini Mioche"" within Pacific Pallisades Village shopping center. Scope include new interior non bearing partition, finshes, millworks and ceiling.CONNECTED LOAD IS APPROX. 40A WITH 484 SF OF AFFECTED AREA"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43329	16041-10001-20452	1514 W 94TH ST	90047	8	094-5A195 405	6055005045	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM			PC Approved	09/22/2016 12:00:00 AM	ADDRESS	33.95101	-118.30315	Changes to approved set.  Relocating inverter, AC disconnect, and meter.PV1, rooftop solar installation, 3.0 kW Ac system,    (11) Solar city standrad module    (1) PVI-3.0-OUTD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43330	13041-10000-10157	521 W 6TH ST 102	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	VERIZON WIRELESS TI  IN HIGHRISE BUILDING, SUITE 102 ON GROUND FLOOR.  ALTERATIONS SUBJECT TO CRA CLEARANCE BEFORE ISSUANCE OF PERMIT (HISTORICAL BLDG).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43331	16041-20000-33714	6031 N KESTER AVE	91411	6	177A149    84	2242027013	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.18028	-118.45762	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from manufacturing to music studio/tenant improvement. Total lighting area = 2,000 sq. ft.Note: Building application has been generated under 16016-20000-06805	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43332	18041-20000-24835	8008 N VAN NUYS BLVD	91402	6	189B149   632	2212028019	[Q]C2-1-CDO, [Q]C2-1VL-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.21647	-118.44851	ti to an existing commercial building single story.  adding new lighting new controls to new panel.  newly connected load <400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43333	15041-10000-05324	2837 S OLIVE ST	90007	9	120A205   136	5122011008	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Expired	03/21/2017 12:00:00 AM	ADDRESS	34.02347	-118.27314	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3600  SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43334	12041-10000-03160	4680 W WILSHIRE BLVD 3RD FLOOR	90010	4	132B185    29	5090009020	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Expired	04/15/2014 12:00:00 AM	ADDRESS	34.0618	-118.33112	TI ON THE 3RD FLOOR OF AN EXISTING OFFICE BLDG. EPC IS FOR T24.  Permit is under Inspection for new lighting, circuits and panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43335	15041-20001-11273	1564 W 45TH ST	90062	8	111B193   301	5016008007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM			PC Approved	04/27/2015 12:00:00 AM	ADDRESS	34.00269	-118.30558	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 6.12 kWac.  Microinverter system with two branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43336	15041-10001-40231	11311 W PENDLETON ST Unit B	91352	6	198B173     2	2538010006	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM			PC Approved	11/07/2016 12:00:00 AM	ADDRESS	34.23563	-118.37732	"11/07/16Changes to an approved set of plans. All changes are made under delta 2. Changes include replacing the 300KVA transformer with a 225KVA transformer, feeder sizes, revising conduit sizes, and removing panel ""A"" from the single line diagram. Note: Permit is paid under PCIS#15041-10000-40231"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43337	15041-20000-20801	23509 W WINDOM ST	91304	12	186B093   241	2027036002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.20669	-118.64062	$0 permit fee due to senate bill 1222 from 2012Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (3) inverters, (50) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43338	13041-10000-17732	23426 W HAYNES ST	91307	3	180B093   480	2036016007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.18976	-118.63752	PV1 3.45KW MICROINV 1STORY. STD. ROOFMOUNT.[ 16MICRO INVERTER: : ENPHASE ENERGY M215-60-2LL-S22] [MODULE:  {REC 230 PE}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43339	16041-20000-04523	4641 N LIBBIT AVE	91436	5	168B137   565	2284001022	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.15463	-118.48875	"""$0 permit fees due to senate bill 1222 ""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.7 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43340	18041-20000-00030	17448 W RUSHING DR	91344	12	219B129   541	2608032009	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.2949	-118.51488	pv1install roof mounted pv sysem sized 8.4kw interconnected with ,msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43341	13041-10000-32959	9927 N BABBITT AVE	91325	12	201B133    52	2694013026	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.25112	-118.51014	PV1, Install  7 kw DC roof-mounted solar array interconnect with service panel.Transformerless inverter: SOLAREDGE SE6000-US. 28 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43342	13041-20001-22225	23140 W ERWIN ST PV-1	91367	3	177B093   369	2039009011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.18262	-118.63113	Expedite fee.PV-1. Rooftop single family dwelling. Two 6kW and one 4kW for 16kW total AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43343	19041-10000-05441	17383 W SUNSET BLVD SUITE A420	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Info Complete	02/14/2019 12:00:00 AM	ADDRESS	34.03917	-118.55529	PLAN CHECK FOR T24 ONLY FOR TENANT IMPROVEMENT ON (E) COMMERCIAL OFFICE. TOTAL AREA: 2,670 SQ.FTB# 18016-10000-39642	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43344	19041-20002-07353	5225 N BLAKESLEE AVE	91601	2	171B173   535	2350018084	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			07/15/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Issued	07/15/2019 12:00:00 AM	ADDRESS	34.16534	-118.37263	07-15-2019 Changes to an approved set of plan, Change include reduce number to PV Modules count to 700 PV Modules, new system size: 255.55KW DC, 233.46KW AC and remove one of the Supply side tap disconnect. $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43345	15041-10000-31026	9448 N TOPANGA CANYON BLVD	91311	12	198B101    79	2746013020	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM			Reviewed by Supervisor	10/02/2015 12:00:00 AM	ADDRESS	34.24211	-118.60602	PC FOR POWER AND ENERGY. FIRST FLOOR . CHANGE OF WHAREHOUSE TO  MANUFACTURING . DISTRIBUTED POWER WITH 11 (200A) PANELS, AND 2(1000A) PANELS. TOTAL AREA 24914 SQ FT.B# 14016-20000-26017	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43346	17041-10001-43673	717 N FULLER AVE	90046	5	141B181   458	5526009030	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			Reviewed by Supervisor	12/15/2017 12:00:00 AM	ADDRESS	34.08416	-118.34995	expedite per applicant requestNEW ROOFTOP SOLAR SYSTEM CONSIST OF 39 MODULES (LG LG3602w-G4) AND 39 MICROINVERTERS (ENPHASE IQ6-60-X-US).  SYSTEM SIZE IS 14.04KWdc and 9.36KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43347	12041-10000-25475	6061 W SUNSET BLVD	90028	13	147A189    44	5545008007	[Q]C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM			Verifications in Progress	11/16/2012 12:00:00 AM	ADDRESS	34.09819	-118.32082	New 800 Amp service to connect to existing distribution board. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43348	15041-10000-40149	11755 W WILSHIRE BLVD 13TH FLR	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	PIN	34.04869377	-118.46238681	TI UPGRADE NON COMPLIANT RESTROOMS TO ADA COMPLIANT RESTROOMS.  TOTAL AREA 1,667SQ.FT. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43349	14041-10000-11927	2122 W YOSEMITE DR	90041	14	160-5A223 155	5685006007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.13471	-118.21395	PV1 5.355KWdc. 240V. xmfrLESS/Ungnd. std. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(21)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43350	12041-10000-12157	4733 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	ADDRESS	34.0469	-118.3401	Change of use from retail to restaurant. Yogurtland. Less that 100 occupants and 400A load. Plan check for energy and emergency lighting. 1145 sqft. Single story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43351	13041-20000-06513	6038 S ARLINGTON AVE PV-1	90043	8	105B189   775	4007001010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Expired	04/10/2015 12:00:00 AM	ADDRESS	33.98439	-118.31853	PV-1. Micro inverter standard plan. 3.0kW total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43352	16041-20001-00990	8156 N BURNET AVE	91402	6	192B145   582	2209006010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	34.21956	-118.46344	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43353	09041-30001-24662	2049 S CENTURY PARK EAST 3050	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM			PC Approved	03/18/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check revision Delta 3 only. TI - existing office space area in highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43354	16041-10001-12575	950 W MANCHESTER AVE	90044	8	097-5A199 276	6038010032	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	33.95985	-118.29058	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW CIRCUITS AND RECEPTACLES TO AN EXISTING RESTAURANT SPACE. PERMIT FEES HAVE BEEN PAID FOR UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43355	15041-20001-17541	629 S JUNE ST	90005	4	135B185   445	5507017007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.064	-118.33481	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SERVICE 600 AMPS. SYSTEM SIZE: 7KW. (26) LG LG305N MODULES WITH SOLAR EDGE P400 OPTOMIZERS. SOLARD EDGE SE 7600A US INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43356	16041-30000-31548	1731 S FEDERAL AVE 1-25	90025	11	126B149   590	4262019024	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			09/06/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.04169	-118.4517	Plan check for new fire alarm system in 25 units appartment building. Total alarm divices: 127 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43357	16041-20000-03771	1999 S AVENUE OF THE STARS 5TH	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 5TH LEVEL OFFICES.HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43358	10041-20000-23602	110 S FAIRFAX AVE # A14	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.07371	-118.36119	energy plan check freshii	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43359	10041-10000-05133	6033 W CENTURY BLVD 500	90045	11	090B169    17	4124030037	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	06/30/2010 12:00:00 AM	ADDRESS	33.94572	-118.38954	Title 24 for high rise , 4th floor suite 500. and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43360	15041-10000-29399	12000 S VISTA DEL MAR ERB BLD	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	PIN	33.92817449	-118.43220714	Plan check for an existing fire alarm system with all new devices and (1) existing fire alarm panel. Scope include (1) communication panel, (4) power supplies, and (147) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43361	17041-10000-13946	10107 S PALOMA AVE	90002	8	091-5A207 190	6050036007	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	33.94449	-118.26389	PV INSTALLATION OF 3.8 KW DC/3.4  KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOME. 12 AC MODULES. PLAN CHECK ONLY, PERMIT FEE IS PAID UNDER 17041-90000-13946	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43362	14041-10000-13563	1038 W PRINCETON DR	90292	11	105B149   516	4229003048	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	33.9859	-118.44654	PLAN CHECK FOR POWER FOR EXISTING OFFICE BUILDING. DOING SERVICE UPGRADE AND NEW PANELS AND LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43363	19041-20001-49207	18840 W VENTURA BLVD	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Approved	05/05/2020 12:00:00 AM	ADDRESS	34.17186	-118.54425	***EXPEDITE FEES***NEW ROOF MOUNTED 105.3KW PV SYSTEM WITH 322 @ 327WPV PANELS 161 OPTIMIZERS AND 2 @ 43.2KW INVERTERS ON A COMMERCIAL BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43364	12041-20000-25166	6330 W SAN VICENTE BLVD 401	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.06116	-118.36804	Plan check for energy and emergency lighting. 4201 sqft. Suite 401. Commercial office. High-rise. Express permit for 21 general use circuits, 2 circuits for 277 lighting, and two AC units less than 5 kVA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43365	15041-10000-39961	555 W 5TH ST 35TH FLR	90013	14	130-5A211 161	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI TO FULL 35TH FLOOR. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43366	16041-10000-36014	360 E 2ND ST	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Issued	11/17/2016 12:00:00 AM	ADDRESS	34.04805	-118.24012	Installation of new fire alarm to existing office building. Instaling 1 New fire alarm panel, 10 boosters, 4 communication panels (annunciators) and 376 fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43367	19041-20000-27692	661 N DIMMICK DR pv1	90065	1	150A223   266	5466013032	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.10554	-118.21118	pv1install roof mounted pov system sized 14.7KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43368	18041-10000-14360	6510 W SANTA MONICA BLVD	90038	13	144B185   748	5533013001	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	01/10/2022 12:00:00 AM	ADDRESS	34.09059	-118.33141	PC FOR EXISTING NIGHT CLUB TI.SCOPE INCLUDES NEW PANEL, LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 3665 SQ. FT(INDOOR + OUTDOORS) B# 17016-10000-21373	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43369	14041-20000-08755	6922 N ORION AVE	91406	6	183B145   530	2234026029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.19634	-118.47042	install roof mounted pv system. sysrem size 9.25kw	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43370	15041-20001-03725	13026 W GOLETA ST	91331	7	204B161   329	2623015004	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	34.25561	-118.41636	Restamp for lost plans.  Plan check only.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43371	17041-10000-40250	6508 N MOORCROFT AVE	91303	3	180B101   575	2139025001	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.18861	-118.61097	PLAN CHECK FOR ROOF MOUNTED PV ON SFD. TOTAL SYSTEM SIZE 9.6KWAC (AC  MODULES)SCOPE INCLUDES 30 AC MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43372	11041-10000-21107	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM			PC Approved	10/04/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I. to an existing restaurant.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43373	16041-10000-36361	1354 W 20TH ST	90007	1	126A201   291	5056028024	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	02/11/2017 12:00:00 AM	ADDRESS	34.038	-118.28547	PV1 ground mounted solar system installation. Inverter size is rated at 5.0 KW which is being fed by one string of 20 solar modules with its respetive optimizer.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43374	13041-10000-12943	840 W CHILDS WAY	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Info Complete	05/17/2013 12:00:00 AM	ADDRESS	34.02065	-118.28634	13041-10000-12943tI, T 24 ONLY FOR it CLOSET LOAD AT usc UNIV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43375	12041-10000-27895	216 S SPRING ST	90012	14	130-5A213  83	5149007005	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.05121	-118.24586	TI for a cupcake shop. EPC is for T24. Contractors board was contacted, contractor has applied for exemption of workers comp and is in process 1/7/2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43376	15041-10000-04927	16826 W MONTE HERMOSO DR	90272	11	138B117   398	4431030003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM			Verifications in Progress	03/19/2015 12:00:00 AM	ADDRESS	34.07076	-118.55439	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  (2 inverters with a total of 5 strings)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43377	17041-10003-00690	5860 W JEFFERSON BLVD	90016	10	120B173  1729	4205027022	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM			PC Info Complete	01/14/2019 12:00:00 AM	ADDRESS	34.02504	-118.37633	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 4 (BULLETIN 02).  CHANGES INCLUDE REMOVING/ADDING RECEPTACLES, AND ADDING THREE NEW BRANCH CIRCUITS. ALSO, REVISING PANEL SCHEDULES TO REFLECT CHANGES ON THE FLOOR PLANS. NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-00690	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43378	11041-10000-22857	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	04/02/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	REMODEL THE RECEPTION/WAITING AREA OF THE HEALTH EDUCATION OFFICES IN THE MOB-2 LOWER LEVEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43379	19041-10000-14894	8379 W MELROSE AVE	90069	5	141B173   439	5528002067	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.08378	-118.37279	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT OF AN EXISTING RETAIL SPACE. SCOPE OF WORK INCLUDES NEW EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 3137 SFB#19016-10000-08728	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43380	18041-10000-19112	1717 N ALTA MURA ROAD	90272	11	135B133   188	4425002025	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.06292	-118.5029	Plan check for a PV1 12.6KW AC roof mounted system with (36) AC module interconnecting through the subpanel.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43381	14041-10000-22368	1861 S BUNDY DR Bldg 5	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Public Safety Only			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.0352	-118.45736	new fire warning system for commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43382	14041-10000-18948	1231 N SAN FERNANDO ROAD	90031	1	144A217   404	5445006907	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Closed	12/21/2016 12:00:00 AM	ADDRESS	34.09459	-118.231	New 108 unit apartment and future commercial. Plan check for power and energy. 5 typical units. No methane for applicant. Plan checker to verify fees. Applicant will bring a new set of plans designed for the old 2010 energy code. Fire alarm variance has been filed already.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43383	18041-10000-18424	810 E PICO BLVD #106	90021	14	123A211   202	5132019030	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.03119	-118.25079	plan check for power/energy in FIRST TENANT SPACE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43384	12041-10000-26741	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	12/03/2012 12:00:00 AM	ADDRESS	33.78734	-118.29768	PLAN CHECK FOR ENERGY AND TITLE 24 ENERGY. 3 STORY BUILDING. UNIT EQUIPMENT. OFFICES ONLY (NO EXAM ROOMS). 3214 SQFT. 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43385	18041-10000-37988	8201 N VAN NUYS BLVD	91402	6	192B149   506	2210010022	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.22009	-118.44896	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43386	14041-20000-14554	22149 W AVENUE MORELOS	91364	3	168B101   872	2170015068	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Info Complete	06/02/2014 12:00:00 AM	ADDRESS	34.15369	-118.60904	pv1 single family. total system size 3.6 kw ac using transformerless inverter. using standard plan.redudant. ignore	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43387	13041-20000-05422	3502 S TROUSDALE PKWY B15G, B15H	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	03/01/2013 12:00:00 AM	ADDRESS	34.02175	-118.28408	T-24 for remodeled office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43388	12041-20000-28359	17627 W CALVERT ST	91316	12	177B129   240	2229034018	R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.18189	-118.51719	Enphase system on roof of single family dwelling with service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43389	17041-20000-09824	9243 N CATHWELL LANE	91042	7	198B201   423	2572048003	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.23723	-118.27808	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.68 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43390	17041-10000-35894	9514 N RESEDA BLVD #8	91324	12	198B125    31	2764008020	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.24339	-118.53587	PC FOR TI FOR NAIL SALON FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES INSTALLING NEW LIGHTS AND NEW CIRCUITS.TOTAL AFFECTED AREA 950SQ.FTB#17016-40000-27550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43391	19041-10000-01314	12400 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	33.97727	-118.4065	PC TITLE - 24 ONLY AREA 3971SF. TEANT IMPROVMENT, REVISED POWER LIGHTING AND LOW VOLTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43392	14041-20000-15760	9240 N CREEMORE DR	91214	7	198B205   453	2572002025	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.23747	-118.2678	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, three strings. System size: 7kW.(1) SMA Sunny Boy 7000-US-12 transformered inverter(21) Sunpower SPR-E20-327 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43393	19041-20000-40347	9745 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	34.24644	-118.41942	New distribution, power, and lighting for (E) building with (E) 600A 240/120V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43394	12041-20000-05946	4901 S FIGUEROA ST	90037	9	111A201   136	5018023028	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	33.99854	-118.28288	coin laundry	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43395	19041-20000-16033	15260 W VENTURA BLVD Suite 200	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check for Title 24 only. Project site is an existing commercial tenant space on the 2nd floor of a high-rise building. Project scope is a tenant improvement. Total lighting area = 11,436 sq. ft.Note: Building permit has been issued under 19016-10000-04393	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43396	19041-20000-52389	2300 S PURDUE AVE	90064	11	123B153   177	4260023007	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	08/21/2020 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	34.03534	-118.44153	$0 permit fee due to AB1414 and SB1222PV3.  Install 106.65 KW DC/96.235 KW AC CEC roof mounted PV system.  (270) modules with (4) 20 KW inverters and a 112.5 KVA transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43397	19041-20000-18263	307 N NEW HAMPSHIRE AVE	90004	13	138B197   260	5520020006	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.07669	-118.2934	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43398	12041-20001-12106	13330 W RIVERSIDE DR	91423	4	168B157   334	2359023003	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM			PC Approved	06/12/2012 12:00:00 AM	ADDRESS	34.15738	-118.42406	Changes from previously approved plans.  Changes include lighting fixture ballast.  All changes indicate by DELTA-1 as shown on plans.  Plan check for energy only.*****Multipurpose room lighting upgrade.  Energy, emergency*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43399	16041-20000-26606	6420 W WILSHIRE BLVD #220	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.06365	-118.36922	plan check for Title 24 only on existing space. Total area: 1,819 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43400	16041-10002-30642	835 W JEFFERSON BLVD 7-C	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	PC FOR POWER FOR FIRST TIME TENANT. THIS IS PLAN CHECK ONLY!! PERMIT UNDER MASTER. **********************************************************************************TI FOR OFFICE SPACE IN EXISTING ROOM. NEW LIGHTING. WORK DONE IN BUILDING 7 SUITE 7-C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43401	17041-20000-04133	380 WORLD WAY T-85	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Title 24 only. Project site is an existing tenant space within the Los Angeles International Airport. Project scope is an electric sign installation. Total lighting area = 77 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43402	14041-10001-32439	200 WORLD WAY # 234	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM			PC Approved	05/06/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES MARKED DELTA 5 ON THE PLANS.  PC FOR POWER AND ENERGY. TERMINAL 2 BUILT BURGER (234). TI. TOTAL AREA  915 SQ FT.PLAN CHECKER TO VERIFY THE FEES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43403	10041-20002-25712	4600 W SPERRY ST	90039	4	165B201   177	5593007004	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Closed	04/18/2012 12:00:00 AM	ADDRESS	34.14823	-118.27596	Changes from previously approved plans.  Changes include replace 400A main panel.  All other PV devices are existing and to be remained.*****New roof mounted P.V. system for commercial building. *****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43404	18041-30000-20846	7402 W SUNSET BLVD	90046	4	147B181   653	5550022010	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM			PC Info Complete	06/05/2018 12:00:00 AM	ADDRESS	34.09785	-118.35195	Plan check for T24 only, TI on (E) commercial space, install new lightings, add and remove loads from existing panelboards, add (1) 100A panel and (1) 200A panel, total new loads <200A. Total area: 7607 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43405	19041-20000-49901	1732 N BRIDGEPORT DR	90065	1	148-5A217  40	5464028014	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.10298	-118.22755	Plan check for PV roof mounted system, PV system size: 3.960KW with 12 PV Modules and 12 microinverters. Center fed panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43406	17041-10000-37580	419 N MOUNTAIN VIEW AVE	90026	13	138A207   315	5157023024	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			Verifications in Progress	04/30/2018 12:00:00 AM	ADDRESS	34.07053	-118.26681	PC for new 9kW roofmounted PV commercial system. Installing 43 PV modules with optimizers and one 9kW central inverter connected to center fed panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43407	19041-20000-11082	2905 N WASHINGTON BLVD	90292	11	108B149  1642	4229017048	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	33.98835	-118.45155	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN EXISTING LOW RISE COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES 1 FA PANEL AND 9 FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43408	15041-10000-22419	707 W WILSHIRE BLVD 1400	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM			PC Approved	07/15/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	T-24 TO AN (E) OFFICE BUILDING. SCOPE INCLUDES REMODEL OF OFFICES AND RECEPTION AREAS. PC FOR ENERGY ONLY. PC ONLY.  TOTAL SQ. FT. 2724. INSPECTION FEES PAID UNDER EXPRESS PERMIT #15041-90000-19393.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43409	17041-10000-31743	6569 W DE LONGPRE AVE	90028	13	147A187   258	5547026041	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.09624	-118.33278	** NO FINAL FEES DUE TO SENATE BILL 1222PC FOR NEW PV SYSTEM WITH BATTERY STORAGE. SYSTEM INCLUDES 28 MODULES, CENTRAL INVERTER AND 2 BATTERY UNITS RATED 5.8KW EACH. TOTAL OF 27KWH OF STORAGE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43410	14041-10000-30005	16490 W EL HITO PL	90272	11	132B121   120	4420017020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2014 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Expired	04/04/2017 12:00:00 AM	ADDRESS	34.05962	-118.54179	PV 1 ROOFMONTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. 2 INVERTERS AND 50 MODULES AND SYSTEM SIZE 12.75KW.$0 PLAN CHK FEE DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43411	16041-20000-15663	11068 W RANDALL ST	91352	6	198B173   103	2408003041	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.23641	-118.37213	PLANCHECK FOR T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43412	12041-20000-02013	17167 W SUPERIOR ST	91325	12	201B133   407	2692013009	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM			Corrections Issued	03/13/2012 12:00:00 AM	ADDRESS	34.24678	-118.50792	pv system single family micro inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43413	10041-10000-04606	1010 W MARTIN LUTHER KING, JR BLVD	90037	9	114B197   265	5020029026	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	06/09/2010 12:00:00 AM	ADDRESS	34.01067	-118.29205	New PV system installed on the roof of a gas station canopy to provide power for the facility.  Check if any hazardous issues affect the PV installation.  The system will require the main circuit breaker of the 200 ampere subpanel be changed to 150 amperes.  The designer indicates that the existing service is provied only with a 200 ampere disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43414	13041-10000-06160	5501 N VAN NOORD AVE	91401	5	174B161   632	2345009008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.17034	-118.41515	PV1 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 3.672 KW. 17 SOLAR MODULES. [MICROINVERTER: ENPHASE ENERGY M215-60-2LL] [SOLAR MODULE: REC MODEL#: REC 245 PE]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43415	14041-10000-04441	324 E 4TH ST	90013	14	129A213   377	5148006025	C2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.04597	-118.24392	T24 only.Removing HID light fixtures and replacing with new fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43416	10041-20000-04678	21747 W ERWIN ST	91367	3	177B105   124	2146029017	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	12/14/2010 12:00:00 AM	ADDRESS	34.18325	-118.60307	""" AS BUILD "" plan (  delta 1,3,4 : 4 new panels, original panels A, B,H  has been revised )original is 08041-20000-25748"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43417	14041-20000-26204	4433 N DEANWOOD DR	91364	3	165B113   107	2174024007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.15017	-118.57477	pv1install roof mounted pv system sized 8.4kw interconnected with msp.(41) kyocera kd255gx modules(2) abb pvi-4.2-outd inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43418	16041-10000-10783	17847 W CHATSWORTH ST	91344	12	207B129   359	2712030032	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.26508	-118.52314	PC FOR POWER AND ENERGY. FIRE DAMAGE REPAIR IN A DENTAL OFFICE. TOTAL AREA 2180 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43419	19041-10000-29205	11517 N BIANCA AVE	91344	12	213B129   250	2607011020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.2799	-118.51422	PV1. SYSTEM SIZE OF 12.35 KW DC WITH (38) MODULES (DUO-G5 325) AND OPTIMIZERS (P340) INTERCONNECTED WITH (2) INVERTERS (SE7600H).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43420	18041-30000-29659	16133 W VENTURA BLVD GROUND FLO	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM			PC Approved	08/07/2018 12:00:00 AM	ADDRESS	34.15675	-118.4847	Plan check for T24 only on TI of (E) Bank at the ground floor. Total area: 5,215 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43421	17041-10000-46345	1032 S CRENSHAW BLVD	90019	10	129B189    73	5081004024	C2-1-O	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.0536	-118.32335	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 14250SQFT. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43422	18041-10002-07818	1487-1489 W SUNSET BLVD C;D;E;F;G;-H;I	90026	13	139-5A209 265	5406001017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.07579	-118.25466	PC ONLY. changes to an approved set of plans, changes include the revision of service entrance conductors. Note changes on delta 4, clouded areas. ______________________________PC FOR CHANGE OF USE FROM OFFICE TO RESTAURANT. SCOPE INCLUDES NEW PANELS, RECEPTICAS AND LIGHTING. PROJECT ADDRESS 1487-1489	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43423	19041-10000-08671	2230 E NORFOLK ST	90033	14	133-5A225  19	5202005900	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.06069	-118.20081	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43424	19041-10000-25388	811 W 7TH ST 5TH FL	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.04908	-118.25911	T-24, PC ENERGY ONLY. TI OF 5TH FLOOR ONLY. TI FOR AN OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 7,800 SQ. FT. B#19016-10000-19711	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43425	16041-20001-35337	9509 N VASSAR AVE	91311	12	198B101    24	2746016062	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	34.24327	-118.60486	[ CHANGES TO APPROVED T24 ONLY. DELTA 1 CHANGES. CHANGES ARE CLOUDED. CHANGES TO FIXTURE AND AREA TYPE]]Plan check for energy only. TI to existing office. New lighting (incl. emergency) and receptacles. T24 - 4,825sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43426	18041-10000-34626	4355 N SEPULVEDA BLVD	91403	4	166-5A145 186	2276042018	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Issued	10/15/2018 12:00:00 AM	ADDRESS	34.14923	-118.46811	"PLAN CHECK FOR OUTDOOR SIGN - NEW WALL SIGN 10'-3 1/2"" W x  1' H; 10.25 SQFT; 9'-10"" ABOVE GRADE TOTAL AFFECTED AREA  100 SF."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43427	16041-10000-39142	4157 N ELM VIEW DR	91316	5	165B125   309	2184051014	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.14666	-118.53201	PV, INSTALL NEW 16900WDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(52) MODULES: PANASONIC OF SSANYO VBHN325A16 (2) INVERTERS: SOLAREDGE SE7600A-US-240	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43428	14041-10000-19814	4821 N LANKERSHIM BLVD #A	91601	2	168B173   395	2353025048	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.15818	-118.37082	CHANGE OF USE FROM RETAIL TO RESTAURANT. TENANT IMPROVEMENTS. NEW NON-BEARING WALLS, T-BAR CEILING, L.Y.P. BD. CEILING. NEW ACCESSIBE RESTROOM AND INTERIOR FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43429	17041-10000-24155	12727 W SATICOY ST	91605	2	186B161   450	2305026027	CM-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.2067	-118.41038	Remove HID fixtures and replace with new LED fixtures - T 24 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43430	17041-10000-12410	740 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A201 122	5019025023	C2-1, R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.01093	-118.28686	PC FOR POWER AND ENERGY. New 5-Story Automobile Dealership Building, 1600 A  277/480V 3 PPHASE 4 WIREED SERVICE. TOTAL AREA 205436.89 SQ FT. B # 16010-10000-02038	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43431	19041-10000-50111	2650 N LISCO PL	90046	4	153B177    56	5571011004	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/11/2021 12:00:00 AM	ADDRESS	34.11908	-118.35405	PER AB#1414 & SB# 1222 FEE =$0.00NEW PV-1 SOLAR SYSTEM. CONSIST OF 204 TESLA SRV3 ROOF TILES, (2) CENTRAL INVERTERS, (DELTA SOLIVIA 5.2 EACH), AND (3) TESLA POWER WALL. SYSTEM SIZE IS 10.4KW AC & 11.92788KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43432	13041-10000-28195	3720 N LOWRY ROAD	90027	4	154-5A203  75	5592006012	R1-1	Central	Hollywood	Greater Griffith Park	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.11834	-118.27659	PV1.  Install 5.184 kW AC rooftop-mounted solar array, interconnect with main service panel.  Microinverters: Enphase M215-60-2LL.  24 modules: Trina Solar TSM-250-PA05	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43433	18041-10000-11226	4524 N VARNA AVE	91423	4	165B157    56	2360019024	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	34.15254	-118.42455	Plan check for battery back up system connected to existing PV system in SFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43434	14041-20002-20105	800 N PASEO MIRAMAR	90272	11	129B117    28	4416022039	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2014 12:00:00 AM			Corrections Issued	09/18/2014 12:00:00 AM	ADDRESS	34.04968	-118.55753	Modification to approved set.  Change of grounding means for solar module frames, from lay-in lugs with #6 AWG bare copper wire to S-5! racking system listed under UL 2703 for PV racks acting as equipment grounds for module frames.  Variance for installation of product prior to test lab approval filed.  $0 permit fee is due to Senate Bill SB-1222.  (((PV1.  29 KW SOLAR SINGLE FAMILY)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43435	14041-10000-27740	333 S ALAMEDA ST # 213	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.04448	-118.23824	TENANT IMPROVEMENT IN A DENTAL OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43436	12041-10000-21325	12222 W WILSHIRE BLVD	90025	11	126B145   356	4263001***	[T][Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM			PC Approved	09/10/2012 12:00:00 AM	ADDRESS	34.04288	-118.46867	Ti in an existing office. EPC is for T24.(suite# 105)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43437	15041-10000-26351	631 S LOS ANGELES ST A	90014	14	127-5A211 108	5148021019	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.04407	-118.24996	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43438	16041-20001-41847	642 S BURNSIDE AVE	90036	4	135B181   779	5508011021	[Q]R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	34.06362	-118.34919	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building.30kW (10*3) ungrounded system. (86) 360W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43439	18041-30000-25673	9200 N OAKDALE AVE STE. 800	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Expired	09/26/2018 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for T24 only, TI on Conferecnce and training room in (E) office space Ste. 800. New circuits/ loads are connect to existing panels. Total area: 875 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43440	16041-20001-31171	7779 W VERAGUA DR	90293	11	099B153    67	4114002014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM			PC Approved	09/26/2016 12:00:00 AM	ADDRESS	33.96481	-118.43382	EXPEDITE PER APPLIACNT.PV1INSTALL ROOF MOUNTED PV SYSTEM (ACM) SIZED 10.5KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43441	12041-10000-16307	1875 S CENTURY PARK EAST 21st Floor	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.06115	-118.41457	Relocate lighting fixtures and add new outlets and lighting fixtures in an existing high-rise building.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under inspection.  21st Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43442	19041-10000-06375	15570 W ROXFORD ST	91342	7	225B145   290	2501004021	[T][Q]M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.31185	-118.47076	"CONVERSION OF (E) OFFICE/WAREHOUSE BLDG. INTO NURSERY. The area of operation is considered as ""Dry"" location and Non-Classified / Non-Hazardous. Flammable / Explosive materials are not allowed to be used in this area.  New 3000A, 480/277V, 3ph, 4W service equipment, total area under the SOW: 25,614 sq.ft(B# 19014-10000-00107)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43443	19041-10000-05750	20225 W DEVONSHIRE ST	91311	12	204B113   156	2707023900	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.25737	-118.57357	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43444	17041-20001-33232	12940 W ADDISON ST	91423	4	168B161    16	2358023021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.16107	-118.41537	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (27) modules. PV system interconnects with a 400-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43445	16041-10000-18457	10731 W SATICOY ST	91352	2	186B177   169	2409014040	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.20859	-118.36503	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(19)MODULES-CANADIAN SOLAR CS6X-310P(19)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43446	13041-10000-17472	940 S CROCKER ST	90021	14	124-5A211 190	5132002035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	34.03519	-118.24991	PV2.  Plan check for new roof mounted 34.2KW (DC) photovoltaic system commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43447	12041-10000-12180	3817 W 3RD ST	90004	10	135B197   161	5518008025	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM			Verifications in Progress	07/12/2012 12:00:00 AM	PIN	34.06922623	-118.29873996	PLAN CHECK POWER. INSTALLATION OF REMEDIATION TREATMENT COMPOUND AND EQUIPMENT. SITE LOCATED IN METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43448	13041-20002-03925	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	34.0344	-118.45642	changes to approved set of plans. changes to site lighting t24 energy only. site lighting 82000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43449	17041-30000-26570	100 S ORLANDO AVE	90048	5	138B173   633	5511015001	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			08/03/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.07432	-118.373	Plan check for new fire alarm system for 24 units appartment building. Total fire alarm devices: 135 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43450	19041-10000-11363	16804 S VERMONT AVE	90247	15	066B197   119	6121009055	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	33.8788	-118.29096	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43451	19041-10001-17613	10573 W SCENARIO LANE	90077	5	151-5A151 554	4380009022	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	ADDRESS	34.1094	-118.44895	***expedite fees***PV1 roof mounted 7.6 KWac/ 6.754KWdc, installing intergrated roof modules roughly 1200 sqft. Scope of work includes central inverter (Salivia 7.6) connected to a  200 A load center and a 13.5 KWH energy storage system , leading to a 200 A main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43452	11041-20000-20738	1826 S COTNER AVE	90025	5	126B153   274	4323026900	PF-1XL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.04443	-118.4436	PLAN CHECK POWER. NEW 600A SERVICE AND EQUIPMENT FOR CNG FUELING STATION. SITE ON METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43453	17041-20000-03700	19520 W NORDHOFF ST	91324	12	195B117    12	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.23378	-118.55808	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM AN OFFICE TO A DANCE ACADEMY. 4325 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43454	12041-10001-27492			5	144B173   404	4337002048	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			Corrections Issued	04/02/2013 12:00:00 AM	PIN	34.08693945	-118.3767689	MODIFICATIONS TO APPROVE SET OF PLANS. REAR BUILDING REMOVED FROM PROJECT/SCOPE OF WORK. PERMIT PULLED UNDER 12041-10000-27492.  ******************************************************ORIGINAL 12041-10000-27492 DESCRIPTION: TI TO EXISTING RESTAURANT. PLAN CHECK FOR ENERGY. METHANE BUFFER ZONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43455	16041-10000-00534	210 W 7TH ST	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.04461	-118.25275	New electrical service for CVS, 600 MSA. PC for Electrical system only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43456	10041-20000-00889	1150 N DOHENY DR	90069	5	144B169   407	5560031007	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.09188	-118.39029	Change from previously approved plans )08041-20000-24204).  Changes include feeders, lighting, and panel loads.  All changes indicate by DELTA 8 and DELTA 9 as shown on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43457	14041-10000-12383	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	NEW FIREALARM FOR 12 STORY high rise BUILDING. 1259 DEVICES. Inspector to verify if sprinkler coverage is adequate for telephone circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43458	15041-10000-40509	19801 W NORDHOFF PL STE 110	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.23568	-118.56464	TI TO AN EXISTING COMMERCIAL BUILDING. REMOVE EXISTING HID LIGHTING AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 6720	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43459	16041-20000-40280	11944 W MONTANA AVE PV-1	90049	11	129B145   296	4265019033	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.05138	-118.47125	Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 19.7kW (6kW*2+7.7kW) ungrounded system. (75) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43460	18041-20001-22671	13060 W ROSCOE BLVD	91352	2	192B161   102	2304005023	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.2215	-118.41867	Expedited plan check fee.PV2.  Install 61.2 kW roof mounted grid tied PV system.  (170) modules with 20 and 30 kW rated central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43461	18041-10000-40457	6290 W SUNSET BLVD B	90028	13	147A189   227	5546025029	(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Info Complete	04/24/2019 12:00:00 AM	ADDRESS	34.09777	-118.32646	TENANT IMPROVEMENT TO EXISTING RESTAURANT TITLE 24 ENERGY ONLY  BUILDING PERMIT 18016-10000-34260	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43462	16041-20000-45681	1042 W DOWNEY WAY	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	34.02169	-118.29124	Plan check for energy only. Renovation of existing office space and conference room. New lighting (incl. emergency) and receptacles. Rooms 145 and 156 (on first floor). 883sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43463	13041-10000-21173	11886 W ELDRIDGE AVE	91342	7	216B169    37	2531034008	(T)R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM			Not Ready to Issue	08/07/2013 12:00:00 AM	ADDRESS	34.28556	-118.39051	(((changes to approved set of plans (13041-10000-01651: from REC 245 to REC 250. charged under OLD fees PER APPLICANT))) PV1 3.672KWAC 240V MICROINV 2STORY. STD. ROOFMOUNT.[( 17) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43464	19041-10000-02874	1831 S LA CIENEGA BLVD UNIT #A	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Expired	09/18/2019 12:00:00 AM	ADDRESS	34.04346	-118.37696	T-24 ONLY PC FOR A TENANT IMPROVEMENT (NO CHANGE OF USE) OF A RESTAURANT (JERSEY MIKE'S). SCOPE INCLUDES RELOCATING PANEL-A (225A), NEW 125A PANEL, CIRCUITS, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA 1355 SQ.FT B# 19016-10000-02190	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43465	15041-10000-16611	1840 S CENTURY PARK EAST 3RD FLR-RSTRM	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Closed	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHING ONLY.  TOTAL SQUARE FOOTAGE 368.  SCOPE OF WORK IN THE 3RD FLOOR RESTROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43466	18041-10000-34857	7101 S PLAYA VISTA DR	90094	11	099B157   503	4211025***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Issued	01/04/2019 12:00:00 AM	ADDRESS	33.9695	-118.42599	PLANCHECK FOR POWER ONLY. INSTALLATION OF AN EMERGENCY GENERATOR AND TRANSFER SWITCH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43467	12041-20000-28206	20310 W PLUMMER ST	91311	12	198B113    79	2748022075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.2426	-118.5759	Plan check for energy and emergency lighting. Single story commercial. 11121 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43468	18041-10000-46405	3000 S HOOVER ST	90007	9	121-5A201 220	5123005916	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.02712	-118.28376	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43469	16041-10000-36136	3940 S INGLEWOOD BLVD	90066	11	111B157   135	4214021025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.00361	-118.42662	TITLE 24 ONLY FOR EXISTING OUTDOOR COMMERCIAL BUILDING. ROMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 4385	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43470	19041-10000-27346	4535 E EAST ROSE HILL DR	90032	14	142-5A229 304	5305026010	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Expired	11/15/2023 12:00:00 AM	ADDRESS	34.08405	-118.19355	PV1. New LADWP Community Solar Program: 3.00KWdc / 2.16 kWac - 9 solar modules and 9 enphase IQ7-60-2 micro-inverters. Solar system is interconnected at existing service point of the single family home.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43471	14041-10002-29867	722-736 E WASHINGTON BLVD	90011	9	121-5A209 156	5131006005	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM			PC Approved	07/08/2016 12:00:00 AM	ADDRESS	34.02718	-118.2568	Plan check only.  Changes to approved set.  Relocating occupancy sensors in common area corridors.  Adding and relocating smoke detectors in dwelling units.     ***Previous scope of work***     FULL PLAN CHECK FOR NEW 4 STORY MULTI-FAMILY BUILDING WITH  55 APARTMENT UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43472	19041-20000-28553	19260 W DEARBORN ST pv1	91324	12	198B117   189	2762017036	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.23713	-118.55227	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43473	12041-10000-29650	5001 N ARUNDEL DR	91364	3	171B117   514	2175014027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Tarzana, Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.16166	-118.56316	SINGLE STORY PV1 ROOF MOUNTED SOLAR INSTALLATION AND INTERCONNECTION TO MAIN SERVICE PANEL. USING STANDARD PLAN WITH 48 TOTAL MODULES IN 4 STRINGS OF 12. SYSTEM SIZE IS 10.56KW. [INVERTER: FRONIUS # IG PLUS V10.0-1 |||| MODULES: KYOCERA # KD220GX-LFBS]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43474	17041-20001-10997	14911 W CALVERT ST	91411	6	178-5A149 317	2242024048	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	PIN	34.18170177	-118.45786314	08/22/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the distribution equipment in order to address the methane buffer zone requirements.*****Preivous Work Description*****service upgrade to an existing commercial building 1600 amps with new panels.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43475	18041-20000-33496	24090 W LANCE PL	91307	12	186B089   624	2027048002	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.20348	-118.64965	PV1.  Install 6.3 kW DC/7.6 kW AC roof mounted grid tied PV system with 9.8 kWh energy storage system. (18) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43476	14041-20000-01550	17190 W SUNSET BLVD	90272	11	126B117   110	4415017007	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.04422	-118.55195	"T24 FOR EXISTING RELIGIOUS FACILITY ""SELF RELIZATION FELLOWSHIP WINDMILL""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43477	19041-20000-31640	14611 W ISLA VISTA DR	91402	6	201B149   885	2650019058	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.24756	-118.45087	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON A NEW SFD. SYSTEM SIZE IS 3.15KW DC/2.835 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43478	14041-20000-23877	21300 W VICTORY BLVD suite 670-&suite 675	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check for energy only. TI for office on 6th floor of high rise office building. New lighting incl. emergency. 1275sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43479	19041-10000-47936	11177 N TAMPA AVE Suite B	91326	12	210B117    35	2701004014	(Q)C2-1, C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.27402	-118.55793	"TI IN AN EXISTING OFFICE AREA IN SUITE ""B"", INSTALLING NEW LOADS AND LIGHTS. TITLE 24 PLAN CHECK ONLY. AFFECTED AREA: 2501SFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43480	12041-20000-06992	3470 S MCCLINTOCK AVE	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.0236	-118.28768	fire alarm system for CINEMATIC ARTS CLASSROOM BUILDING.  IIB FULLY SPRINKLERED STRUCTURE. GROUP B OCCUPANCY. 3 STORIES PLUS 1 STORY UNDERGROUND. USC. *PLEASE STAMP 5 SETS IF APPROVED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43481	10041-10000-21870	711 N NORTH MAIN ST # 104	90012	1	133-5A215 234	5408013033	C2-2	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	08/19/2011 12:00:00 AM	ADDRESS	34.05862	-118.23772	RETAIL STORE  CHANGED TO MINI-MARKETPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43482	16041-20000-16532	7231 W SUNNYDIP TR	90068	4	156A181   196	2428005052	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.12272	-118.34904	Plan check for PV roof mounted system. System size: 7.3kW with 38 modules and 1 inverter. Home owner builder submit the PV plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43483	18041-20002-48109	11050 W ARMINTA ST 1-110	91352	6	189B173   477	2314008041	(T)(Q)R3-1, (T)(Q)R3-1-CUGU, QRD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	Apartment			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.21377	-118.37214	SUPPLEMENTAL PLAN CHECK ONLY, CHANGEs TO APPROVED SET, CLOUDED DELTA 1 CHANGES ONLY. ELEVATOR MOTORS ARE DOWNSIZED, FEEDER SCHEDULES AND VOLTAGE DROP CALCS ON PAGE E0.03, E0.03A, E0.03B ARE UPDATED, PANEL SCHEDULE PAGE UPDATE, DOWNSIZING PANEL BUS SIZES, DOWNSIZING BRANCH CIRCUIT BREAKERS, AND REPLACEMENT OF GFCI RECEPTACLES WITH AFCI/GFCI COMBOS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43484	13041-20000-27745	1808 S MANTIS AVE	90732	15	012B189   169	7562010014	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	33.72855	-118.31417	((ZONING WAS DONE ON ORIGINAL APPLICATION# 13041-10000-19290))PV1 9kw Xfmr AND XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [ 2 INV: PVI-3.6-OUTD-S-US (transformerless) and PVI-4.6-I-OUTD-X-US-Y (isolated)] [ 36 MOD: TRINA {TSM-250PA05.08}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43485	18041-20000-03995	3550 S OVERLAND AVE	90034	5	120B161   876	4314011059	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			02/02/2018 12:00:00 AM			Verifications in Progress	01/19/2021 12:00:00 AM	ADDRESS	34.02383	-118.41069	Plan check for a PV2 roof-mounted PV system. System size is 18 kWac and consists of (2) inverters, (62) modules, and (1) load centers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43486	19041-20000-01967	18746 W MAPLEWOOD LANE	91326	12	207B121   834	2728031021	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.26014	-118.5409	PC FOR PV SYSTEM. SYSTEM SIZE IS 13.2KW (DC) - 12.141KW (AC). 40-PANASONIC MODULES. 40 ENPHASE MICROINVERTERS. 1 COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43487	16041-20002-12236	12751 W MILLENNIUM A160	90094	11	102B161  1175	4211033020	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	[[ 6/6/16 CHANGES TO APPROVED SET. RELOCATION OF PANELBOARDS AND ADDITION OF 2 PANELS TO MEET TITLE 24 DISAGGREGATION REQUIREMENT]]PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43488	16041-10001-15364	18350 W HATTERAS ST 101-184	91356	3	174B125    27	2157015***	(Q)RD1.5-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.17721	-118.53258	EXPEDITED FEES PER APPLICANT.PV2, ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS, TO AN APARTMENT UNIT. TOTAL SYSTEM SIZE: 64.5 KW.   SYSTEM IS BEING USED FOR COMMON AREAS IN A NEW 1600 AMP SWITCHGEAR, PV MONITOR SYSTEM INCLUDED. (300) TRINA SOLAR MODULES, (150) MODULES TIE INTO PANEL A AND (150) MODULES TIE INTO PANEL B. (300)  ENPHASE M215 MICROINVERTERS WITH 3 SUBPANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43489	12041-20000-30624	1801 CENTURY PARK EAST 23rd floor	90067	5	129B161    45	4319005045	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	04/02/2013 12:00:00 AM	PIN	34.05319661	-118.41824601	Plan check for energy. Mostly existing wiring. Commercial high rise. 23rd floor. 3250 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43490	12041-20000-04837	3878 N ALONZO AVE	91316	5	162B125   192	2184048002	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	ADDRESS	34.14132	-118.52627	Roof mounted 12.74 KW PV SYSTEM for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43491	17041-10001-15653	11615 W AYRES AVE 1-4	90064	11	123B153  1167	4260033***	RD1.5-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.03164	-118.44394	EXPEDITED RSES PLAN CHECK PER APPLICANTREQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43492	12041-20000-08392	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	TI for existing retail space. Plan check for power and energy. 15156 conditioned sqft. Single story commercial building. Forever 21.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43493	14041-10000-11961	380 WORLD WAY T-72	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Install illuminated signage not visible from ROW.( Four identicl signs) T-72	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43494	12041-10001-08514	1600 S HOPE ST	90015	9	124-5A205 107	5134014905	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.03599	-118.26771	CHANGES TO APPROVED SET OF PLANS. RELOCATED FACP FROM LOBBY TO ELECTRICAL ROOM. USED ANN AND FAA  AS A SUBSTITUTE CONTROL FROM LOBBY. CHANGES APPROVED BY FIRE DEPARTMENT CAPTAIN ROBERT FRANZ WITH LETTER ON PLANS.This is a four story building, new fire alarm , floor 1 through 4. need fire department stap.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43495	16041-10000-39887	15526 W VENTURA BLVD	91436	5	168B141   697	2283001021	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.15472	-118.4732	PC FOR T24 ONLY. REMOVE E HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA  40573 SQ FT. PERMIT WILL INCLUDE ENTIRE SCOPE INCLUDING EXEMPT T-24 (ATHLETIC FIELD) LIGHTING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43496	10041-10000-18029	2748 W HYANS ST 1-4	90026	13	138A203   256	5156022013	RD1.5-1	Central	Westlake	Rampart Village	YES	2086.20	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	09/15/2011 12:00:00 AM	ADDRESS	34.07253	-118.27796	New site lighting. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43497	17041-10000-13951	1864 W 38TH PL	90062	8	117B189   948	5035027024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	34.01634	-118.31557	PV INSTALLATION OF 3.84 KWac ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOME. 12 AC MODULES.NOTE: Permit is paid under PCIS#17041-90000-11920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43498	13041-20000-23802	3217 W ORILLA AVE	90065	14	160-5A217 207	5679024014	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.13321	-118.2339	PV1 TRANSFORMERLESS SYSTEM. 20 MODULES AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43499	19041-10000-24798	3517 S SPEARING AVE	90732	15	009B189   300	7563025006	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Expired	10/03/2023 12:00:00 AM	ADDRESS	33.7217	-118.32324	S0.00 fee due to senate bil 1222 and lb 1414[EPLAN]PLAN CHECK FOR 11.4KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400A-US) WITH 26 MODULES USING P400 OPTIMIZERES, AND ESS CONSISTING OF 3 TESLA POWER WALLS CONNECTED TO AN EXISTING  200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43500	11041-10000-12790	5101 W MELROSE AVE	90038	13	141B193   538	5535015014	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			06/20/2011 12:00:00 AM			Verifications in Progress	07/08/2011 12:00:00 AM	ADDRESS	34.08364	-118.3116	NEW 600 A SERVICE UPGRADE FOR EXISTING 20 UNIT APARTMENT BUILDING WITH ALL NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43501	12041-20000-10202	653 W 28TH ST	90007	8	121-5A203  83	5123015400	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			05/04/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	08/14/2012 12:00:00 AM	ADDRESS	34.02696	-118.27903	sorority housing remodel new service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43502	14041-10000-33763	12516 W OSPREY LANE 1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	33.97884	-118.41153	Install (N) fire alarm system with (50) notfiication and initiating devices for multifamily dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43503	10041-20000-03575	10860 N TOPANGA CANYON BLVD	91311	12	210B101    77	2722004015	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM			PC Approved	03/01/2010 12:00:00 AM	ADDRESS	34.26773	-118.60586	OUT DOOR LIGHTING PARKING AREA OF ARENA. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43504	19041-20000-51869	4458 E MONT EAGLE PL	90041	1	154-5A221  67	5474043018	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1862.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.11921	-118.2185	Plan check for PV roof mounted system, PV system size: 3.3KW with 10 PV Modules and 10 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43505	19041-20000-06779	20600 W ROSCOE BLVD 6	91306	3	192B109   856	2108001033	(T)(Q)R3-1, (T)(Q)RD3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM			Corrections Issued	02/25/2019 12:00:00 AM	ADDRESS	34.21987	-118.58192	Plan check for Title 24 only temporary Sales Office and Design in the small lot subdivision. Total area: 121 sq ft. B#16010-20000-05962	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43506	17041-30000-42215	1164 N NAPOLI DR	90272	11	129B133   227	4408003008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.04929	-118.5032	Plan chck for New two story single family dwelling with attached garage. Plan check for power only. Permit for electrical is under Combination Permit 15010-30000-04019	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43507	15041-20000-20235	15064 W ROXFORD ST	91342	7	228B145   294	2502005022	RA-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.32039	-118.4611	Plan check for PV roof mounted system. System size: 6.1kW with 24 microinverters and 24 modules. Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43508	17041-10002-23838	10000 S WESTERN AVE	90047	8	091-5A193  74	6059001033	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	33.94524	-118.30881	Changes to approved set: relocate utility's production meter before the PV AC disconnect. Zero fee per CA Senate Bill 1222<<PV2, NEW ROOF SOLAR SYSTEM IN A 2 STORY BUILDING USING CENTRAL INVERTERS. (2) SOLAREDGE INVERTERS 20K AND 33.3K, (156) CANADIAN SOLAR MODULES AND (78) OPTIMIZERS. TOTAL SYSTEM 53.3Kac. NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43509	10041-10000-01379	3129 W 8TH ST	90005	10	132B197   460	5094009023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM			PC Info Complete	01/27/2010 12:00:00 AM	ADDRESS	34.05787	-118.29516	TI for a yogurt shop.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43510	17041-20000-15690	19130 W CHARLES ST	91356	3	168B121   226	2176031008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Issued	06/12/2017 12:00:00 AM	ADDRESS	34.15733	-118.55007	pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43511	19041-10000-10966	10250 W SANTA MONICA BLVD 2370	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Issued	04/18/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK FOR A TI TO AN EXISTING RETAIL SPACE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1308 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43512	15041-20000-24866	21318 W SATICOY ST	91304	3	186B105   167	2112007002	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.20815	-118.59609	Title 24 plan check only.  Replace 14 light fixtures in existing restaraunt space. 1,662sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43513	19041-10000-00419	13161 W MINDANAO WAY UNIT D6A	90292	11	105B153    86	4212004004	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Issued	01/08/2019 12:00:00 AM	ADDRESS	33.98499	-118.43772	PC FOR T-24 ONLY. SCOPE OF WORK INCLUDE A TI FOR A BEAUTY SALON 1435SFNote: Partial electrical permit fees have been paid for under 18041-30000-24243.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43514	15041-10001-34167	827 W AMOROSO PL	90291	11	108B149   630	4241025024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM			PC Approved	10/23/2015 12:00:00 AM	PIN	33.99332478	-118.45823841	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<<PV1, ROOF MOUNTED SOLAR SYSTEM. (14) MODULES AND (1) INVERTER. TOTAL SIZE 5KW.(14) SUNPOWER DPR-X21-345(1) SMA AMERICA SB5000TL-US-22>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43515	19041-10000-03074	3640 W WILSHIRE BLVD #140	90010	10	132B193    62	5093019018	(T)(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Issued	01/30/2019 12:00:00 AM	ADDRESS	34.06145	-118.30446	TI 24 PC FOR CORE AND SHELL LOW RISE COMMERCIAL SPACE, TOTAL SQUARE FOOTAGE = 1520ALL FUTURE EMERGENCY LIGHTING IN THE UNIT TO BE CONNECTED TO EXISTING EMERGENCY BACKUP GENERATOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43516	12041-10000-25182	1036 S GRAND AVE	90015	9	127-5A207 268	5139010007	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.04202	-118.26128	T24. 6655 SF. COMMERCIAL [WAREHOUSE]. NO EMERGENCY LIGHTING PER APPLICANT. DEMO EXISTING INTERIOR ELECTRICAL. INSTALL 21 NEW FLUORESCENT LTG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43517	17041-10000-32417	1411 W 190TH ST # 650	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM			PC Info Complete	09/12/2017 12:00:00 AM	ADDRESS	33.85852	-118.30317	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT OF 7,225 SF OFFICE SPACE, (E) 400A DIST BOARD, ADD (2) NEW PANELS, 200A AND 100A, TOTAL NEW LOAD < 400A(B#17016-10000-25674)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43518	19041-20000-50991	11401 W TUXFORD ST	91352	6	195B169   221	2408038001	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Issued	01/16/2020 12:00:00 AM	ADDRESS	34.22862	-118.37977	NEW 1600A 480V 3-PHASE SERVICE TO FEED PORTABLE PLANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43519	18041-20000-47172	2551 N PARK OAK DR	90068	4	153B193    62	5580022013	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.11716	-118.31338	Plan check for PV roof mounted  Energy Storage system , system size: 16.8kW DC, 13.6kW AC with 48 PV modules and 2 inverter(7.6kW and 6.0kW), and Battery Sonnen ECO 10(10kWh).Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43520	17041-20000-00640	21006 W INGOMAR ST	91304	3	189B109   888	2109018012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.21182	-118.59111	PV1.  Install 3.15 kW roof mounted grid tied PV system.  System is being combined with (E) 3 kW PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43521	14041-20000-32240	13703 W VICTORY BLVD	91401	2	180B157   930	2238013053	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM			Corrections Issued	11/19/2014 12:00:00 AM	ADDRESS	34.18683	-118.43167	NEW FOODMART. LOAD LESS THAN 400A. NEW LIGHTING. PC FOR T24 ENERGY ONLY. PER APPLICATION, NO FUELING. NON HAZARDOUS AS OF THIS APPLICATION. BUILDING ONLY.PER BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43522	15041-10000-27825	4319 N SALTILLO ST	91364	3	165A107    26	2172012060	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.14819	-118.59366	PV1, NEW ROOF MOUNTED SOLAR SYSTEM. (22) MODULES AND (1) 6K INVERTER. UNGROUNDED TRANSFORMERLESS INVERTER, SUBMITTAL PER APPLICANT'S REQUEST.   (22) SUNPOWER SPR-E20-327(1) SB6000TL-US-22 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43523	17041-20000-16922	1841 N HIGHLAND AVE	90028	4	150A185   269	5549018032	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.10493	-118.33776	Plan check for Title 24 only. Project site is an outdoor parking lot. Project scope is outdoor lighting. Total lighting area = 19,320 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43524	12041-10000-19448	21505 W RINALDI ST	91311	12	210B105   275	2723004020	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM			Reviewed by Supervisor	09/13/2012 12:00:00 AM	ADDRESS	34.27132	-118.59951	PLAN CHECK POWER AND ENERGY. NEW SINGLE STORY CLASSROOM BLDG (BLDG 6). (APPLICATION 6 OF 6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43525	13041-10000-01286	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			Corrections Issued	01/17/2013 12:00:00 AM	ADDRESS	34.07666	-118.3805	TITLE 24 ONLY FOR NEW LIGHTING PLAN TO ILLUMINATE AREA UNDER AN OVERPAST. TOTAL AREA OF 14,000 SQ FT. INCLUDES 1 NEW PANEL FOR LIGHTING CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43526	18041-30000-01611	10850 W NATIONAL BLVD	90064	5	123B157  1152	4254008037	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.03015	-118.42138	Plan check for Title 24 only in existing space indoor LED retrofit. No new wiring. Total area: 11,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43527	18041-10000-15074	1234 W WILSHIRE BLVD	90017	1	130-5A207 637	5143019***	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05329	-118.26612	INSTALL 20 EV CHARGING STATIONS ON TWO PARKING LEVELS IN A HIGH RISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43528	14041-10000-29105	11800 N FOOTHILL BLVD 2nd fl	91040	7	210B165   540	2528002901	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District, Pacoima	YES	9800.21	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	12/26/2014 12:00:00 AM	ADDRESS	34.273	-118.39313	"Tenant improvement for ""Hockey on Ice""exhibit at Discovery Science BuildingPlan chk is for title 24  only"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43529	19041-10000-24023	200 WORLD WAY Temp	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/27/2021 12:00:00 AM	ADDRESS	33.94558	-118.4039	Power plan check for temp' power located in LAX Terminal 2. Scope includes (1) 1200-amp distribution panel and other equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43530	14041-10000-09908	10324 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.25804	-118.57961	CHANGE OF USE FROM RETAIL TO BANK. PC FOR ENERGY AND EMERGENCY LIGHTING. TENANT IMPROVEMENT FOR A NEW LOGIX CREDIT UNION BANK IN AN EXISTING SINGLE STORY SHOPPING CENTEER. TOTAL AREA 3905 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43531	17041-10000-28766	10250 W SANTA MONICA BLVD FC 25	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	FIRST TENANT-TOSAI SUSHI- FC 25FULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43532	16041-10000-11421	1717 E 7TH ST	90021	14	124-5A215  56	5164022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.03495	-118.23573	MAIN SERVICE UPGRADE TO 600 AMPS ONLY, FOR FUTURE TENANT. NO CONNECTED LOAD.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43533	17041-10001-17429	1318 E 7TH ST 154	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Closed	05/17/2019 12:00:00 AM	ADDRESS	34.03608	-118.24052	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE REVISED LIGHTING. UPDATED T24. ADDED WALK IN COOLER TO PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43534	18041-10000-39400	6101 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	33.93236	-118.39253	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43535	17041-10000-20096	1950 S SAWTELLE BLVD 120	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.04129	-118.44377	PC FOR T24 ENERGY ONLY. PC FOR LIGHTING UPGRADES. OFFICE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43536	11041-20000-27687	127 S SAN VICENTE BLVD Bulletin-129TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM			PC Approved	12/30/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin # 129CS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43537	18041-30000-25579	10575 W SELKIRK LANE	90077	5	153A151   813	4380002014	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM			Reviewed by Supervisor	09/12/2018 12:00:00 AM	ADDRESS	34.11162	-118.44953	Plan check for Power only to a (E) SFD, service upgrade from 400A to 600A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43538	19041-10000-25590	6531 N WINNETKA AVE	91306	3	180B113   562	2134023011	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.18927	-118.57122	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 13 MODULES (Q-CELL 305) , 13 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.965KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43539	19041-10000-11465	1120 S GRAND AVE SUITE 103	90015	14	126A207    60	5139020094	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.04095	-118.26231	PC FOR FIRST TIME  TENANT (N) PHARMACY, MARKETPLACE AND CAFE (IN ONE SPACE).SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 4038 SQ.FTB#19016-10000-08776	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43540	14041-20000-29405	4365 N MAMMOTH AVE 1-24	91423	4	165B153   378	2271017027	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			11/12/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.15002	-118.43269	PV2.  THIS SYSTEM IS A 20KW PV SYSTEM WITH 2 INVERTERS. 84 MODULES. SYSTEM IS A LOAD SIDE CONNECTION. ROOF MOUNTED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43541	15041-10000-33493	877 S FRANCISCO ST R2	90017	14	129A207   122	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.04791	-118.26383	CORE AND SHELL TO TWO SEPERATE HIGH RISE MIX USE, RETAIL, PARKING, AND RESIDENTIAL BUILDINGS. R-2, RESIDENTIAL  TENANTS ON 42 FLOORS  AND R-3, RESIDENTIAL  TENANTS ON 60 FLOORS.  TWO SEPERATE SERVICES FROM DWP INTO ONE VAULT,  TWO 4.16KV, 1600 AMP SERVICES. ***RETAIL/PARKING PODIUM, BUILDING R2, AND BUILDING R3 ALL PLAN CHECKED UNDER ONE APPLICATION. HOWEVER, THE PERMIT FEES ARE SPLIT BETWEEN 3 APPLICATIONS. BUILDING R2 PERMIT FEES ARE ON THIS APPLICATION NUMBER. PERMIT FEES PULLED UNDER INSPECTION,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43542	16041-10000-24930	3580 W WILSHIRE BLVD 1000	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.06156	-118.3028	title 24 energy only with (8530sq. ft.),.TI FOR OFFICE SPACE(SUITE 1000).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43543	18041-10000-22303	830 S WALL ST	90014	14	126A211   254	5145010030	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.03931	-118.25096	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43544	18041-20000-04062	2466 E 16TH ST	90021	14	118-5A217 294	5168010013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.01949	-118.2277	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,600 sq. ft.Note: Building application has been generated under 18016-20000-03252	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43545	19041-20000-47263	7239 N WHITE OAK AVE	91335	3	186B129  1266	2121016017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.20244	-118.51878	PV1 PLAN CHECK FOR NEW PV, SYSTEM SIZE 8.96 KW DC/7.98 KW AC. SCOPE OF WORK CONSISTS OF (28) PV MODULES WITH OPTIMIZERS, AND A 10 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43546	10041-20000-23349	11611 W SAN VICENTE BLVD #845	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	ADDRESS	34.0541	-118.46261	T.I. to existing high rise building on 8th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43547	12041-10000-25491	555 S FLOWER ST 5th Floor	90071	9	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI IN AN EXISTING OFFICE AREA ON THE  5TH FLOOR. PLAN CHECK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43548	12041-10000-11412	4418 S LONG BEACH AVE EAST	90058	9	112-5A213 152	5106004009	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM			PC Approved	05/17/2012 12:00:00 AM	ADDRESS	34.00314	-118.2429	PLAN CHECK T24 ENERGY FOR INDOOR/OUTDOOR LIGHTING NEW REPAIR SHOP FOR RECYCLED WOODEN PALLET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43549	14041-20000-09567	9121 N COLUMBUS AVE	91343	7	198B145   366	2656023036	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.23611	-118.4656	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 3.6KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. TOTLA OF 20 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43550	12041-10000-10613	669 W 34TH ST	90089	9	120A201   206	5123023024	RD2-1XL, [Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	PIN	34.02214675	-118.28186522	Plan check T24 Energy mandatory measures for USC MRF classroom remodel #206 and 229.  No new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43551	17041-20001-39694	5959 N TOPANGA CANYON BLVD	91367	3	177B101   228	2146006012	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM			PC Approved	01/26/2018 12:00:00 AM	ADDRESS	34.17827	-118.60529	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on commercial building.Total system size: 168kW ungrounded.(7) 24kW Fronius inverters.(626) 310W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43552	19041-30000-34251	5900 W WILSHIRE BLVD # 2325	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	ENERGY PC ONLY FOR PROPOSED TENANT IMPROVEMENT TO OFFICE BUILDING (APPROX. 1,206SQFT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43553	18041-20000-45034	2415 S STERLING RANCH ROAD	91304	12	192B089   182	2017038014	RE11-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Issued	11/27/2018 12:00:00 AM	PIN	34.22014305	-118.65466493	Plan check for a PV1 roof-mounted PV system. System size is 2.83 kWdc/3 kWac and consists of (1) inverter and (9) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43554	12041-10000-25325	14639 W SYLVAN ST	91411	6	178-5A151  75	2241006018	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			10/23/2012 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.1848	-118.4522	PLAN CHECK POWER AND ENERGY FOR 2-STORY 6-UNIT APARTMENT BUILDING OVER GARAGE WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43555	15041-20000-43437	4152 N ADLON PL	91436	5	165B133   416	2292006021	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.14664	-118.50613	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.8 KWac. (50) MODULES-SUNPOWER SPR-327NE-WHT-D(3)INVERTERS- SUNNYBOY SMA SB7000TL-US-22, SMA SB3800-US-22, SMA SB3000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43556	10041-20001-04351	1071 S GLENDON AVE	90024	5	132B153   117	4363020002	C4-2D-O	West Los Angeles	Westwood			2652.02	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM			PC Approved	04/08/2010 12:00:00 AM	ADDRESS	34.0612	-118.4445	Revision and supplimenting to previously approved plan. Lighting setup was changed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43557	18041-10000-13070	1155 S GRAND AVE	90015	14	126A207   315	5139028***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.04053	-118.26327	INSTALL NEW 1200 AMP SERVICE AND 4 @ 112.5 KVA TRANSFORMERS AND PANELS FOR FUTURE EV CHARGERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43558	12041-20000-26840	3232 N OAKDELL LANE	91604	2	159B169   682	2381019008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.12855	-118.38985	PV-1. Plan check for single family dwelling. Transformerless inverter. 16kW.  ((Permit includes fees for monitoring system and new ground rod.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43559	19041-10000-08807	2650 N VERMONT AVE	90027	4	153B193   686	5593002913	OS-1XL	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.11792	-118.29204	T-24 PLAN CHECK FOR  REMODEL OF EXISTING SPACE CAFE RESTAURANT. SCOPE OF WORK INCLUDES NEW CIRCUITS AND LIGHTING. TOTAL SQ. FT. 4318 OUTDOOR AND INDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43560	14041-10000-04165	8063 N GREENBUSH AVE	91402	6	189B157   151	2301008016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.21773	-118.42684	PV1, Install 6.5 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 6000A-US-ZB-U. (26) Modules: CANADIAN SOLAR CS6P-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43561	19041-20002-29289	971 N ENCHANTED WAY	90272	11	132B121   521	4419003019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM			Corrections Issued	09/13/2019 12:00:00 AM	ADDRESS	34.05435	-118.54914	Revision to approved set of plans.  Plan check to show as-built site conditions.  (((Plan check for PV system, PV system size: 19.8KW DC, 18.21KW AC with 60 PV modules and 60 microinverters connected to Existing 600A Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43562	15041-10000-40510	19801 W NORDHOFF PL STE 108	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.23568	-118.56464	TI TO AN EXISTING COMMERCIAL BUILDING. REMOVE EXISTING HID LIGHTING AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 4104	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43563	14041-20000-26980	932 E 25TH ST	90011	9	118-5A209  71	5131026018	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.02017	-118.25587	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW.(1) SMA SB 5000TL-US-12 transformerless inverter(16) SunPower SPR-E20-327 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43564	19041-10000-07570	1027 W WILSHIRE BLVD	90017	1	130-5A207 127	5143025010	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Issued	06/12/2019 12:00:00 AM	ADDRESS	34.05196	-118.26214	NEW FIRE ALARM IN A NEW 9 STORY MIXED USE BUILDING (NOT A HIGH RISE). SCOPE INCLUDES NEW FACP, 17 POWER SUPPLIES AND 1083 DEVICES.PLANS ARE SUBMITTED FOR FIRE APPROVAL SIMULTANEOUSLYB#12010-10000-01448	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43565	10041-20001-03979	5400 N BALBOA BLVD s.311	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1390.00, 1397.01	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	03/17/2010 12:00:00 AM		Permit Finaled	03/23/2010 12:00:00 AM	PIN	34.16914714	-118.50029545	s.311  medical office t.i.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43566	19041-10000-20520	11267 W VENICE BLVD	90066	11	114B157   118	4234002037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.01204	-118.41926	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43567	10041-10000-14708	4570 N GRIFFIN AVE	90031	1	147A227    10	5303024003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco, Historic Highland Park	YES	1993.00	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.09568	-118.2017	New fire alarm system for nursing home. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43568	18041-20000-14149	6080 W CENTER DR SUITE 500	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	33.97713	-118.39172	Tenant improvement for 5th floor commercial office.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43569	19041-20000-49396	5831 N COLUMBUS AVE	91411	4	174B145    81	2243018008	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Issued	12/18/2019 12:00:00 AM	ADDRESS	34.17675	-118.4641	PV1.  Install 6.54864 kW rated solar roof system and 27 kWh energy storage system.  (112) shingle modules and 7.6 kW rated inverter.$0 permit fee per State Senate Bill SB 1222 and AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43570	17041-20001-12001	3737 S BENTLEY AVE	90034										Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	06/23/2017 12:00:00 AM	ADDRESS	34.01482	-118.41685	expeditepv2install roof mounted pv system sized 14.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43571	17041-10000-18807	20233 W CORISCO ST	91311	12	198B113   203	2748001050	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.23549	-118.57422	PC for energy only, Outdoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 24,000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43572	19041-20000-46479	11639 W MISSOURI AVE	90025	11	126B149   927	4262020***	RD1.5-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.03943	-118.45037	PV1.  Install 4.29 kW roof mounted grid tied PV system.  (13) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43573	17041-10000-42316	5300 W ADAMS BLVD	90016	10	123B177  1014	5043006001	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	01/22/2024 12:00:00 AM	ADDRESS	34.03224	-118.35886	PC FOR POWER AND ENERGY FOR A NEW THREE STORY MIXED USE BUILDING. TWO STORY RESIDENTIAL USE TYPE V-A (8 UNITS) OVER ONE STORY TYPE I-A GARAGE AND RESTAURANT.SCOPE INCLUDES NEW SERVICE RATED AT 800A 120/240 3PH. NEW PANELS, EQUIPMENT CIRCUITS. TOTAL AFFECTED AREA 6660 SQ.FT. B#17010-10000-00059	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43574	19041-20000-53729	18642 W PLUMMER ST	91324	12	198B121    95	2763005003	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	34.24261	-118.53969	Plan check for PV roof mounted and Battery system, PV system size: 5.22KW DC, 7.6KW AC with 18 PV Modules and 1 inverter(7.63KW), 1 LG Battery(9.8KWh)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43575	18041-10000-26715	4741 N LIBBIT AVE 1-33	91436	5	168B137   451	2284001016	R3-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Info Complete	08/15/2018 12:00:00 AM	ADDRESS	34.15628	-118.48833	NEW FIRE ALARM SYSTEM IN A 5-STORY, 46-UNITS APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43576	13041-20000-31167	4073 N MURIETTA AVE	91423	4	162B153   121	2272008030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.14357	-118.43683	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 28 MODUES. 2 CENTRAL TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43577	17041-20000-06068	22901 W VENTURA BLVD	91364	3	171B097   459	2042017009	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Issued	03/01/2017 12:00:00 AM	ADDRESS	34.16565	-118.62528	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,282 sq. ft.Note: Building application has been generated under 13014-20000-04221	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43578	18041-20002-45225	10506 W BLOOMFIELD ST	91602	4	165B177   496	2424012011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.1495	-118.35958	Revisions to approved set of plans.  Minor relocation of equipment.  $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414. ((Plan check for PV roof mounted system, system size: 10.08kW DC, 8.99 kW AC CEC with 28 AC Modules))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43579	19041-10000-12986	13003 W VENTURA BLVD	91604	2	165B161   966	2375022103	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Issued	04/10/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	Plan check for a fire alarm system located in a new commercial building with (1) fire alarm panel, (1) control panel, and (12) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43580	18041-10000-39643	1910 S MAGNOLIA AVE	90007	1	126A201   175	5056027037	CM-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.03947	-118.28631	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43581	15041-10000-27888	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Info Complete	08/25/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	PC for energy only for a commercial site 3-story bldg. Scope of work : replacemant of lights in existing office on the third floor. sq ft  = 470	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43582	12041-10000-02468	9301 N TAMPA AVE #212	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	"Title 24 and emergency lighting for a ti, two story building. Sports Authority.  ((Per engineer KC, ""connected load for this project is below the 400A threshold."")))   Full plan check may be required subject to field inspection. Permit for new branch circuits and new AC equipment."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43583	18041-10000-46924	8235 W LINCOLN TER	90069	4	147B173   294	5555024017	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.09777	-118.37009	PC FOR NEW ENERGY STORAGE SYSTEM CONSIST OF 3 UNITS (14KWH EACH - TESLA POWER WALL), 1 125A LOAD CENTER + 200A DISTRBUTION PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43584	17041-10004-02377	433 S SPRING ST	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.04822	-118.24907	REVISIONS TO PERMITTED PLANS: FIRE PUMP MOTOR IS SUPPLIED FROM THE GENERATOR THROUGH THE FIRE PUMP CONTROLLER / TRANSFER SWITCH;800A MAIN CIRCUIT BREAKER PROVIDE SHORT CIRCUIT CURRENT PROTECTION AND FIRE PUMP MOTOR CONDUCTOR FROM GENERATOR IS SIZED 125% OF THE FP MOTOR FLCMODIFICATION WAS FILED TO INSTALL MEANS FOR SUPERVISORY MONITORING OF THE 800A MAIN CIRCUIT BREAKER  OPEN / CLOSED POSITONS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43585	13041-20000-35202	9400 N OAKDALE AVE	91311	12	198B113    97	2761040801	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.24135	-118.56674	T24 FOR EXISTING ADMINISTRATION BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43586	19041-20000-19951	112 N JUNE ST	90004	4	138B185   211	5515003007	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.07442	-118.33415	PV1.  Install 12.73 kW DC / 10.82 kW AC roof mounted grid tied PV system.  (38) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43587	16041-20000-28813	7135 N HAYVENHURST AVE	91406	6	183B137    90	2225004042	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.20027	-118.49257	INSTALL A NEW OPTIONAL  STANDYBY BACKUP 200KW GENERATOR, ATS, AND CIRCUITS IN THE BUILDING FOR METRO PCS. NO BATTERY BACK-UP EMERGENCY LIGHTING AND EXIT SIGNS IN SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43588	15041-20000-17254	6556 N GREENBUSH AVE	91401	2	180B157   496	2329017017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	08/06/2015 12:00:00 AM	ADDRESS	34.19002	-118.42566	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (32) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43589	18041-10000-06600	380 WORLD WAY NBHS-F/A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Public Safety Only			02/22/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	NEW FIRE WARNING SYSTEM AT LAX MIDFIELD SATELLITE CONCOURSE NORTH. TOTAL FA DEVICES 211, AND 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43590	11041-20000-09008	16000 W VENTURA BLVD 5th floor	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	34.15584	-118.48164	Plan check T24 energy general/emergency lighting for Interior tenant improvements corridors and elevator lobby remodel on the 5th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43591	19041-10002-04651	10250 W SANTA MONICA BLVD # 1610	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	DELTA 1 REVISIONS TO PERMITTED SET OF PLANS- NEW CIRCUITS ; CHANGES ARE SHOWN CLOUDED ON THE PLANS(((((((first tenant in commercial space at a mall-Bibigo RESTAURANTFULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43592	18041-10002-15851	933 E VERNON AVE	90011	9	112-5A209  33	5115013025	C2-1VL	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.00407	-118.25923	"REVISION TO AN APPROVED SET DUE TO LOST PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA ""1A"".  CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM, ADDING A 100A PANEL ""HP1"", RELOCATING LOADS ON PANEL SCHEDULES, REVISING FLOOR PLANS, AND REVISING LOAD CALCULATIONS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43593	15041-20001-11932	6250 N TOPANGA CANYON BLVD Suite 1585	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Info Complete	08/24/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	08-24-2015 Change to approved set of plans. Changes include homerun and relocate the receptacles and remove lighting fixture D and change the layout to lighting fixtures on the floor plan. Changes apply to delta 2 only. [[[[[Plan check for power and Title-24 (energy).  Total area = 2,200 sq. ft.T.I. to retail first time tenant.]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43594	15041-20000-20068	6173 N PLATT AVE	91367	3	177B093   322	2033028010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Expired	07/21/2017 12:00:00 AM	ADDRESS	34.18299	-118.64331	Plan check for PV roof mounted system. System size: 7.6kW with 30 modules and 1 inverter(7.6kW) Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43595	15041-20000-32752	9542 N LEMONA AVE	91343	7	201B149   757	2650004032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.24391	-118.45864	Plan check for PV roof mounted system. System size: 12.0kW with 49 modules and 49 micr-inverters. 34 modules connected to sub-panel and 15 modules connected to another  sub-panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43596	12041-10000-11469	10613 W PAWNEE ST	91352	6	192B177   395	2404021030	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.22318	-118.36228	NEW 5.6KW PV SYSTEM WITH TRANSFORMERLESS INVERT ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43597	18041-10000-06131	5800 W SUNSET BLVD BLDG-11	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.09728	-118.31693	INSTALLING FACADE LIGHTING FOR BUILDING 11 -NORTH, SOUTH, EAST, WEST ELEVATIONSPLAN CHECK IS FOR TITLE 24 OUTSIDE LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43598	19041-20000-52721	970 W FRANCISCO ST BUILD - 2	90502	15	057B197    68	7351034066	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	08/21/2020 12:00:00 AM		Issued	08/21/2020 12:00:00 AM	ADDRESS	33.84824	-118.29298	FULL PLAN CHECK, NEW 2000A SERVICE, PANELS WITH LOADS, TRANSFORMERS, AND T24. TOTAL SQUARE FOOTAGE = 290061 SF*****BUILDING 2 OF 3*****BLDG PERMIT #19016-20000-40272	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43599	19041-20000-39198	22322 W COLLINS ST	91367	3	174B101   187	2146010014	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	04/17/2020 12:00:00 AM	PIN	34.17332386	-118.61271322	PV3.  Install 24.75 kW DC / 22.52 kW AC-CEC roof mounted grid tied PV system.  (75) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43600	10041-10000-04231	1508 S FEDERAL AVE	90025	11	126B149    37	4261001014	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Public Safety Only			03/09/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.04535	-118.45436	NEW FIRE WARNING SYSTEM  FOR 5-STORY 61 UNITS OVER 2 PARKING GARAGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43601	19041-20000-25917	1766 S PREUSS ROAD	90035	5	129B169  1284	4303004010	R1V2	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.04679	-118.38489	PV1 PLAN CHECK FOR NEW ROOFOTP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 8.28 KW DC/7.25KW AC. SCOPE OF WORK INCLUDES (23) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43602	13041-20001-28015	14400 W ARMINTA ST	91402	6	189B149   664	2212001015	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.21259	-118.44646	POWER PLAN CHECK ONLY FOR EXISTING COMMERCIAL SPACE. EM LIGHTS AND SWITCHING ALREADY CHECKED ON APPLICATION#: 13041-20000-27560	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43603	14041-10001-31079	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM			PC Approved	04/14/2015 12:00:00 AM	ADDRESS	34.0834	-118.37568	revisions to lighting systemPlan check for power and energy. New 800 A service upgrade for a 2-story building (retail space). Total indoor lighting area = 1,360 sq. ft. Total outdoor lighting area = 800 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43604	14041-20000-23365	19950 W RINALDI ST SUITE 301	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.27535	-118.56939	PC FOR POWER AND ENERGY. NEW LIGHTING. OFFICES. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS. MEDICAL OFFICES. PER ARTICLE 517, WORK DONE IN EXAM ROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43605	16041-20000-34367	6234 N ETHEL AVE	91401	2	177B161   283	2331015016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	PIN	34.18393807	-118.41782605	Plan check for installation of pv system on SFD, roof-mounted. Interconnect with a 100A MSP.2.4kW ungrounded system. (10) EnPhase M250 microinverters. (10) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43606	11041-10000-14765	333 S GRAND AVE 25Th Floor	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.05271	-118.25179	TI IN AN EXISTING OFFICE AREA ON TEH 25TH FLOOR.  EPC IS FOR POWER & ENERGY. FIRE LIFE SYSTEM SUBMITTED UNDER APP# 11041-10001-14765.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43607	14041-10001-35344	18060 W CHATSWORTH ST 1-6	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM			PC Approved	04/08/2015 12:00:00 AM	ADDRESS	34.26446	-118.52593	(((4/8/2015))) REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 8 ON THE PLANS.  REVISIONS INCLUDE REVISING THE LIGHTING FIXTURES AND ENERGY CALCS.T.I. to existing commercial space.  Title 24 plan check only.  Total area = 38,023 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43608	19041-10000-27488	6827 N TROOST AVE	91605	2	183B169   566	2320011005	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.19458	-118.3866	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43609	10041-10000-10823	11000 W VENTURA BLVD	91604	2	162B173   535	2378008001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	06/16/2011 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.14028	-118.37038	First time tenant for a Walgreen store. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43610	14041-20000-11247	21263 W ERWIN ST ROOM 1371	91367	3	177B105    20	2149001029	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.18302	-118.59459	PLANCHECK FOR POWER. KAISER PERMENANTE MEDICAL OFFICE BUIDLING. INSTALLATION OF LOW VOLAGE CONDUIT AND ADDING TWO RECEPTACLES CIRCUITS IN SERVER ROOM. ROOM 1371.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43611	12041-10000-08999	951 W VERNON AVE 1-16	90037	9	111B197    88	5020035013	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.00382	-118.2902	New 16 unit Apt building with new services and T24 for outdoor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43612	19041-20000-47934	7023 N VAN NOORD AVE	91605	2	183B161   443	2327021007	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.19815	-118.41507	PV1 PLAN CHECK FOR ADDITION TO EXISTING PV SYSTEM. ADDING 2.16 KW DC/1.89 KW AC. NEW TOTAL SYSTEM SIZE IS 9.75 KW DC/8.93 KW AC. SCOPE OF WORK CONSISTS OF (6) PV MODULES WITH INTEGRATED MICROINVERTERS AND A NEW SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43613	14041-10000-24369	3854 W TRACY ST	90027	4	150B201   775	5433020015	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.10666	-118.27674	PV1 standard plan,  3.75KW roof-mounted system including one Solaredge SE3000A inverter,(14) Tyocera KD255GX modules and solaredge power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43614	18041-10000-14027	7026 N TOPANGA CANYON BLVD	91303	3	183B101   272	2138002038	P-1VL-RIO, [Q]C1.5-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.19811	-118.60562	FULL PLAN CHECK, FOR FIRST TIME TENANT TI TO GROUND FLOOR COMMERCIAL SPACE.  SCOPE INCLUDES NEW LIGHTS AND CIRCUITS ON EXISTING PANEL ( APPROVED ON CORE AND SHELL).ELECTRICAL CORE AND SHELL UNDER 16041-20000-20715B# 16010-10001-01399	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43615	17041-10000-37828	8500 N LANKERSHIM BLVD	91352	6	192B169   300	2632022004	M1-1-CUGU, P-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.22394	-118.38757	TITLE 24 ONLY, RELACE OUTDOOR EXISTNG FIXURES WITH LED FIXURES, TOTAL SQUARE FOOTAGE 30225	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43616	11041-10000-17939	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	08/29/2011 12:00:00 AM	ADDRESS	34.06664	-118.46903	INSTALL NEW FIRE ALARM SYSTEM FOR TEMPORARY BUILDING AT BRENTWOOD (PRIVATE) SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43617	14041-20001-02681	14329 W CARL ST	91331	6	201B153   520	2644024011	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Expired	04/28/2016 12:00:00 AM	ADDRESS	34.24716	-118.44537	CHANGE IN SET OF APPROVED PLANS. CHANGE IN OCPD RATING TO 30A. ADDITION OF SOLAR MONITORING BOX.$0 PC AND PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43618	19041-20000-29921	2234-2236 W BEVERLY BLVD	90004	13	136-5A205 294	5154010001	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	PIN	34.0672668	-118.27247253	EXERIOR AND INTERIOR TENANT IMPROVEMENT OF EXISTING TWO STORY OFFICE BUILDING WITH BASEMENT; NO CHANGE TO EXISTING PARKING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43619	15041-10001-27802	8480 W 3RD ST	90048	5	138B173   779	5511032029	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.07317	-118.37579	PC FOR CHANGES NOTED DELTA 1 REVISION. PC FOR CHANGE IN DAYLIGHT ZONES ON FLOOR PLANS. INSTALLATION OF PHOTOCELL FOR DAYLIGHT HARVESTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43620	18041-20000-18015	20640 W CHESTNUT CIR (#331)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.29319	-118.584	Plan check for a PV1 roof-mounted PV system. System size is 2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43621	16041-10000-09983	1425 S OCEAN FRONT WALK	90291	11	106-5A143  17	4226007002	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	33.98756	-118.47407	INTERIOR REMODEL OF EXISTING TAKE-OUT (PIZZA) RESTAURANT. INSTALL NEW LIGHTING ON 1ST FLOOR. PC FOR ENERGY ONLY. TOTAL AREA: 1,100 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43622	14041-10000-01472	3740 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.01972	-118.29033	Changes to approved set, changes in excess of 50% of scope of original plan check.  Addition of dimmer switch to control meeting room lectern light.  Permit already issued under 13041-10000-25426.(((PLAN CHECK FOR TITLE 24 ONLY. WORK ON THE GROUND FLOOR OF AN EXISTING  BUILDING ON USC CAMPUS.CONVERT OFFICE SPACE TO MEETING ROOM.  3790 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER._)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43623	14041-10000-35104	11253 W VINEDALE ST	91352	6	192B173   486	2632003047	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.22171	-118.37583	T24 only. remove HID light fixtures and replace with new LED fixtures, total area 2400 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43624	15041-20002-38389	11821 W GWYNNE LANE	90077	5	153B141   106	4378037078	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM			PC Approved	04/08/2016 12:00:00 AM	ADDRESS	34.11581	-118.47468	04/01/2016 Changes to an approved set of plans. PV system now consists (1) 11.4 kWac inverter. Module count has remained the same. *****Previous Work Description*****PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel.(44) SOLARWORLD SW285 Modules(2) SMA America SB6000 TL Inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43625	17041-10000-46298	5657 N LINDLEY AVE	91356	3	174B125   288	2157008073	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.17393	-118.52746	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43626	15041-20000-06832	5166 N LANKERSHIM BLVD Unit D	91601	2	171B173   634	2353005014	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.16457	-118.37421	Plan check for Title 24 only. Project is a tenant improvement to an existing commercial space (restaurant). Total lighting area = 2,083 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43627	15041-20000-04713	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Expired	07/04/2017 12:00:00 AM	ADDRESS	33.87528	-118.29083	Plan check for power and energy for AT&T corporate office. Minor Tite 24 for tunnels. Temporary chillers and replacing pumps in the fan room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43628	19041-20001-12309	19508 W GIFFORD ST	91335	3	186B117  1016	2116020019	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Issued	05/28/2019 12:00:00 AM	ADDRESS	34.20493	-118.5582	"Revision to approved set and reduction in permit work scope: Removal of ESS and critical load backup panel from permit work scope. Downgraded inverter rating from 7.6 to 5 kW.  Permit work description is now in full:""PV1.  Install 5.28 kW DC / 5 kW AC roof mounted grid tied PV system.  (16) modules with 5 kW rated inverter.""$0 plan check and permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414. (((PV1.  Install 5.28 kW DC / 7.6 kW roof mounted grid tied PV system and 9.8 kWh energy storage system. (16) modules with 7.6 kW rated string inverter.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43629	11041-10000-05107	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM			PC Approved	03/15/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	Ti in an existing office building. (16 & 17th floors) Panels are existing, all the branch circuits are new. EPC is for power & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43630	17041-10000-08632	8937 N DE SOTO AVE	91304	3	195B109    57	2779002032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.23271	-118.58872	Plan check for Title 24 only in existing space, Replace existing fixtures with new LED fixtures. Total area: 41,150 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43631	14041-10000-16812	601 W 5TH ST Ste 230	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.05049	-118.25386	permit to be pulled at EPC counter only. plan check for energy only. highrise TI (E) OFFICE. STE 230.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43632	13041-20000-35142	4960 N PALO DR	91356	3	168B117    91	2175006036	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.15957	-118.55497	PV1 CENTRAL INVERTER. 5 STRINGS FOR 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43633	19041-30000-09816	16444 W ROSCOE BLVD	91406	12	192B137   310	2689022001	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.21987	-118.49574	Plan check for a fire alarm system for airplane hangars. Fire alarm system consists of (1) FACP and (170) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43634	14041-10000-16098	1200 E 5TH ST	90013	14	127-5A215 420	5163023001	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Info Complete	12/30/2014 12:00:00 AM	ADDRESS	34.04159	-118.2359	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. UPGRADE OF A NEW PREP KITCHEN AND SITE IMPROVEMENT FOR FOOD TRUCK COMMISSARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43635	15041-20001-11736	6256 N TOPANGA CANYON BLVD C-1200	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	08/10/2015 Changes to an approved set of plans to reflect field changes. Changes include the addition of lighting to a mezzanine. All lighting changes have been reflected onto the Title 24 Compliance Forms. All changes have been clouded and marked Delta 2.*****Previous Work Description*****TI to new commercial building (restaurant). Plan check for power and energy.  Total Sqft. 2235.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43636	14041-10001-24238	2725 N HYPERION AVE	90027	4	151-5A205 224	5433026037	C4-1D, P-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	34.10747	-118.27223	5/25/16: Sbmittal 2 zero fee due to readjustment of initial submittal (DM).05/12/16Changes to an approved set of plans. Changes include adding a 600A distribution board, 4 new subpanels, replacing light fixtures,  and new load equipment. [New Engineer under the same company is responsible for this change.](((((PC FOR POWER AND ENERGY. TI for SUPERMARKET.  TOTAL AREA 19154 SQ FT. INSPECTOR TO VERIFY CUSTOM FIXTURES.PER 2013 ENERGY CODE.B# 14016-10000-17809.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43637	14041-20001-17700	1006 N COLE AVE	90038	13	144B185   888	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Expired	11/09/2017 12:00:00 AM	ADDRESS	34.08915	-118.32971	[[[[CHANGE OF ADDRESS PERMIT FROM 1016 N COLE TO 1006 N COLE.]]]]]PC FOR POWER AND ENERGY PER APPLICANT REQUEST. NEW TRANSFORMER AND SUBPANEL. ADDED LAUNDRY CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43638	16041-20001-34920	8460 N PENFIELD AVE	91306	3	192B113   270	2782010033	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.2237	-118.56872	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (47) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43639	17041-10000-45960	180-184 S ALVARADO ST	90057	13	135A205   153	5154007003	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Info Complete	12/21/2017 12:00:00 AM	ADDRESS	34.0644	-118.27157	T-24, PC for energy only. Tenant improvement to an existing retail commercial building. Scope includes new lights and receptacles. Total affected area is 5015 Sq. Ft. B# 17016-10000-32749Note: Permit is pulled under express permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43640	19041-20002-21926	14136 W ATTILLA ROAD	90402	11	123B129   373	4410027002	R1H1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM			PC Approved	10/15/2019 12:00:00 AM	ADDRESS	34.03393	-118.51159	10-15-2019 Changes to approved set of plans.  Additional energy storage disconnecting means at MSP per DWP requirements.  Wiring revisions and overcurrent protection added to accommodate routing change.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43641	14041-10000-02066	401 S VERMONT AVE UNIT 14	90020	10	135B197   497	5502009020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.21	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.06699	-118.29189	PLANCHECK FOR T24 ENERGY. 2 STORY BUILDING. UNIT 14. TENANT IMPROVEMENT. 1296 SQFT, EMERGENCY LIGHTING. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43642	17041-10003-42332	5971 W VENICE BLVD 2ND & 3RD-FLOORS	90034	10	126B173   912	5066003021	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM			PC Approved	11/05/2018 12:00:00 AM	ADDRESS	34.03865	-118.37272	PC FOR CHANGES TO APPROVED SET (MEDICAL OFFICES) UNDER DELTA 2. NEW ADDED SCOPE INCLUDES WORK DONE IN EXAM ROOMS FOR POWER MINOR CHANGES TO LIGHTS AND T-24 MODIFICATION FOR T-24 CALC, LOAD CALC, SINGLE LINE DIAGRAM AND PANEL RELOCATION AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43643	12041-20000-18221	6600 N TOPANGA CANYON BLVD #1082A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Approved	08/22/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24 lighting plan check for remodeled space 1082A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43644	17041-20000-28211	17606 W CHATSWORTH ST	91344	12	207B129   471	2733009009	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.26463	-118.51788	Plan check for energy only. TI to commercial building - change of use from retail to office. New lighting (incl. emergency) - 1,827sqft indoor, 860sqft outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43645	19041-20000-46487	10639 W LINDAMERE DR	90077	5	150A149    94	4370011015	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.10437	-118.45728	PV1 PLAN CHECK FOR NEW PV SYSTEM, SYSTEM SIZE IS 11.84 KW DC/10.6 KW AC. SCOPE OF WORK CONSISTS OF (32) PV MODULES WITH MICROINVERTERS AND A 125A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43646	17041-20001-28921	21317 W CANDICE PL	91311	12	210B105    23	2706034008	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.27291	-118.59522	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, and (37) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43647	19041-20000-42969	11490 W OXNARD ST 1-12	91606	2	177B169   828	2338010014	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			10/22/2019 12:00:00 AM	01/27/2020 12:00:00 AM		Permit Finaled	11/15/2021 12:00:00 AM	ADDRESS	34.17923	-118.38204	FULL POWER PLAN CHECK FOR A SERVICE OF 800 A, 240/120 V, 3 PH 4 WIRE SYSTEM. TOTAL AFFECTED AREA: 5,981 SQ (INDOOR); 4,884 SQ FT (OUTDOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43648	18041-20000-23866	18348 W CHATHAM LANE	91326	12	213B125   273	2870016031	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.28134	-118.5334	PV1.  Install 13.545 kW roof mounted grid tied PV system.  (43) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43649	17041-20000-16331	6251 N VAN NUYS BLVD #A	91401	6	178-5A151 256	2241012009	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.18376	-118.44897	Plan check for power and energy. TI - Change of use to Dental Office. 2,124sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43650	13041-20001-35740	11510 N VALJEAN AVE	91344	12	213B137   558	2605022017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.2797	-118.48663	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5KWAC. 21 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43651	19041-20000-35339	3165 N HUTTON DR	90210	5	156B157   158	4385024014	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.1259	-118.42973	Plan check for PV roof mounted system, PV system size: 11.292KW with 34 PV Modules and 34 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43652	16041-10000-36159	9901 N MASON AVE	91311	12	201B109    84	2741004026	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.25039	-118.57998	Title 24 plan check only.  Remove HID fixtures and replace with new LED fixtures.  Total area = 75,777 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43653	18041-20000-34141	15950 W SKYTOP ROAD	91436	5	162B141   209	2286016001	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.14066	-118.48088	PV1.  Install 20.46 kW roof mounted grid tied PV system.  (62) modules with (2) 10 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43654	12041-20000-04189	8229 N WYNNE AVE	91335	12	192B125   719	2102022023	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.22027	-118.53015	PV system for SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43655	16041-10000-45342	23201 W OXNARD ST	91367	3	177B093   706	2035024058	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.17919	-118.6324	PV, INSTALL 3.8 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A RESIDENTIAL HOUSE.(12) MODULES: SOLARWORLD SW 300 MONO SOLAR(12) INVERTERl SOLAREDGE P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43656	13041-20000-11263	10054 N WYSTONE AVE	91324	12	204B121   434	2729004020	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.25332	-118.54684	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 9.72KW. [MICROINVERTER: ENPHASE M215-60-2LL-S22] [SOLAR MODULE: CANADIAN SOLAR CS6P-250P]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43657	19041-10000-42190	15401 S FIGUEROA ST	90248	15	072B201   141	6120027006	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	33.89164	-118.28318	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43658	16041-20002-10232	20600 W OAKSBORO CIR	91364	3	168A111    71	2174012027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM			PC Approved	04/08/2016 12:00:00 AM	ADDRESS	34.15477	-118.58204	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.4 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43659	13041-10000-27008	1945 W 26TH ST	90732	15	012B189   522	7563007016	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	33.72525	-118.32016	PV1. ROOFMOUNTED SOLAR ARRAY SYSTEM. 1 STORY HOUSE/ PARTIAL 2 STORY. NON STANDARD PLAN. (36) LDK 250W MODULES(1) FRONIUS IG PLUS 10.0-1 UN1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43660	17041-10000-17018	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.10229	-118.33907	Plan check for Title 24.  T.I. to retail/gallery/cafe space located on 2nd floor of (E) mixed use Hollywood & Highland Center.  Combine 5 tenant spaces into one (suites 213, 215, 217, 219, and 221).  Total area = 5,997 sq. ft.       Building permit #17016-10000-12799	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43661	14041-20001-24825	7010 S HOOVER ST	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 8 modules in total. System connects to unit subpanel. This application is for House panel. total system size 2kw AC. zoning clearance shall be applicable for all solar installations on this building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43662	18041-20000-07021	977 N NORTH BROADWAY flrs 1-5	90012	1	136-5A215 263	5414007022	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.06611	-118.23652	ti to an existing commercial building.  core and shell only.  plan check for power and energy.  (((Exterior upgrades including new metal canopy; demolishing of interior partitions to (E) 5-story, Type IA, office building, with 3 level, Type IA, basement parking garage. No Change of use. Core and Shell only.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43663	19041-10000-30348	16461 W VENTURA BLVD Store#2958	91436	5	168B137   331	2260009044	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM			Verifications in Progress	10/03/2019 12:00:00 AM	ADDRESS	34.15772	-118.49199	PC for T24 only, scope of work is retrofitting existing lights in a exisiting CVS, total affected area is 21961 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43664	15041-10000-01615	380 WORLD WAY Space T85	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM			PC Approved	01/20/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	T.I. to airport concession space #T85 (7-Eleven)  Installation of 1 new panel wtih lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43665	17041-10000-40193	10250 W SANTA MONICA BLVD # 2375	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space ""Me Undies""  suite 2375"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43666	16041-20000-10181	19346 W PARTHENIA ST	91324	12	195B117   257	2783024010	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Expired	04/24/2018 12:00:00 AM	ADDRESS	34.22809	-118.55527	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.84 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43667	16041-10000-05459	3132 E FOLSOM ST	90063	14	127-5A227 226	5178021029	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.04378	-118.19666	PV1 roof mounted solar system interconnnected with the main service. Inverter: 3kw, (9) solar modueles. kiocera-ku2656 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43668	19041-10000-08969	18887 W CARMEL CREST DR	91356	3	162B121   154	2177048006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.14129	-118.54607	$0 Permit fee per AB1414. Plan check for a 11.4KW AC / 11.5KW DC rooofmounted system with (2) inverters, (2) batteries, (32) modules and power optimizers feeding a back up panel, load center and the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43669	16041-10000-28830	21801 W OXNARD ST	91367	3	177B105    56	2146005179	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.17941	-118.60306	Auditoriam #8 remodel. new seating, power and lighitng. pc for theater - full pc power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43670	11041-10002-02930	1717 N GARFIELD PL 1st floor	90028	13	148-5A193 110	5544003002	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			12/23/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.10227	-118.31103	This modification is to reduce the available fault current as reported by the DWP, and to reduce the short circuit current rating of the service and distribution equipment, and relocate panels 1A and 1B to the far side of the room.  No other changes.  See delta 8 modifications.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43671	10041-10000-18552	1626 N LA BREA AVE	90028	13	147B181   278	5548007006	C4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	10/25/2010 12:00:00 AM	ADDRESS	34.1007	-118.34471	Change of use from a gymnasium to a sit down / takeout restaurant with retail space, pool tables and game machines.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43672	16041-10000-36924	11490 N ORUM ROAD	90049	5	144B145   223	4369003008	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			Not Ready to Issue	06/20/2018 12:00:00 AM	ADDRESS	34.08824	-118.46442	Full Plan check for a new 4 story single family residence. New service size rated at 800 Amps 208Y/120V 3 phase 4 wire. All new electrical equipment. Total sqft approx 16824. Electrical permit fees paid under building combination permit 15010-10000-02111	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43673	19041-20000-01880	11645 W WILSHIRE BLVD Suite 600	90025	11	129B145   489	4265001036	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.05013	-118.46034	Conversion of (E) medical office space into operating room and adjoining support areas in a commercial highrise building.  Plan check for power and energy. Note: Building permit has been issued under 18016-30000-39508	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43674	11041-10000-17923	5430 N SAN FERNANDO ROAD WEST	90039	13	165B201   256		M2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM			PC Approved	08/30/2011 12:00:00 AM	ADDRESS	34.15154	-118.275	TI TO AN EXISTING INDUSTRIAL SPACE WITH OFFICES.  PLAN CHECK  FOR ENERGY ONLY.  PERMIT HAS ALREADY BEEN PULLED BY CONTRACTOR, PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43675	19041-20000-44377	8534 N MARKLEIN AVE	91343	6	192B145   136	2654019007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.22557	-118.47082	Plan check for PV roof mounted system installed into existing PV and energy storage system, additio PV system size: 3.78KW with 12 PV Modules and 1 inverter(3.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43676	19041-10001-00078	3790 N MULTIVIEW DR	90068	4	159B177   279	2425009013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.13314	-118.35814	EXPEDITED PER APPLICANT REQUEST. NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH ONE BATTERY BACKED UP SYSTEM(LG CHEM). TOTAL SYSTEM SIZE IS 15.120KWDC AND 12.6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43677	13041-10000-06807	747 N WESTERN AVE	90038	13	141B193   390	5535017001	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1916.10, 1917.10	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	PIN	34.0847511	-118.30949672	CONSTRUCTION OF TENANT SPACE. CHANGE OF USE FROM PREVIOUS RETAIL SPACE TO NEW LAUNDRY MAT. DUE TO NEW LOADS AND CHANGE OF USE, BACK ROOM SUMBITTAL. NEW PANELS AND BRANCH CIRCUITS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43678	12041-10000-04903	301 S WESTERN AVE 110-111	90020	10	135B193   233	5503002022	C2-1	Central	Wilshire			2117.03	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.06877	-118.30952	TI in a hair salon. EPC is for Energey & Emergrny lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43679	12041-10000-23090	20263 W HEMMINGWAY ST	91306	3	189B113   688	2107011048	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.21411	-118.57515	Plan check for 5.886KW roof mounted photovoltaic system using Sunpower transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43680	15041-10001-38433	4247 N EAGLE ROCK BLVD	90041	14	156A219    67	5473024020	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM			PC Approved	04/25/2019 12:00:00 AM	PIN	34.12292955	-118.22381583	revision for an approved set, change marked 2r. no new equipment. change include adjusting demand load total service size remain the same.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43681	18041-20000-44263	6837 N SUNNYSLOPE AVE	91405	2	183B157   847	2328012027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.19529	-118.42709	PV1.  Install 6.73 kW roof mounted grid tied PV system.  (24) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43682	18041-20000-09557	10950 N CARTWRIGHT DR	91311	12	210B113   265	2708030028	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.26995	-118.56621	pv1install roof mounted pv system sized 5.7kw interconnected with msp. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43683	16041-10000-12518	4700 S INGLEWOOD BLVD STE 102	90230	11	108B161   213	4218008012	(Q)C2-1, C2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	33.99346	-118.41537	PC for power and energy. Tenant improvement to a portion of existing pharmacy and dental clinic. (2) new 200 A panels: total connected load is less than 400 Amps. Adding new lighting and power. Total sq ft = 2783.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43684	16041-20000-02254	22735 W CANTLAY ST	91307	12	186B097   980	2022003013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.20205	-118.62259	PV1. Plan check for the addition of a 4.2 kW AC PV system onto an existing 4 kW PV system. For a total system size of 8.2 kW. New PV system consists of(20) Kyocera KU265 Modules(1) ABB PVI 4.2 Inverter(1) Bryant 125A Load Center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43685	17041-10000-03366	357 W 45TH ST	90037	9	112-5A203 116	5110003026	RD2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	PIN	34.00313864	-118.28031895	PC FOR A ROOF-MOUNTED PV SYSTEM USING 3KW AC INVERTER AND 13 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43686	16041-10000-17111	1730 S WESTERN AVE	90006	10	126B193   551	5074014043	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.04188	-118.30883	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RESTAURANT (WABA GRILL). SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND ONE PANEL. TOTAL AFFECTED AREA IS 1643 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43687	19041-10000-23361	10931 N MARKLEIN AVE	91345	7	210B145   356	2664018006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.26925	-118.47063	Note: Fees are $0 due AB 1414(ePlan) PV1  7.6 kW AC / 8.28 KW (dc)/ 7.45 KW (ac CEC) P.V. System with ESS. Install: (23) modules,  (23) P400 optimizers, (1) 7.6 kW inverter, (2) Tesla Battery at 13.5 kWh each, (2) 125A load centers, (1) 225A subpanel.*Note: New 200A Main Service Panel shall be under separate express permit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43688	19041-10000-08675	929 W ACADEMY ROAD	90012	1	141B213    25	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park, Los Angeles Historic Cultural	YES	9800.10	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.07988	-118.2369	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43689	19041-20000-20172	9171 N DE SOTO AVE Units A&B	91311	12	198B109   225	2746009048	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.23778	-118.5888	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant. Occupant load exceeds 100. Total lighting area = 2,542 sq. ft.Note: Building application has been generated under 19016-20000-12675	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43690	13041-20004-35614	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM			PC Approved	05/01/2015 12:00:00 AM	ADDRESS	33.98179	-118.40283	Changes to approved set (13041-20003-35614).  Changes to AIC rating of electrical distribution equipment.  New Isc is lower based on calculations that include feeders between main serviceboard and individual building switchgear.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43691	18041-10001-41326	6307 N WILLOW CREST AVE	91606	2	177B177    74	2414017022	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.1851	-118.3628	DELTA ONE CHANGES TO AN APPROVED SET. ADDITION OF A 60A AC DISCONNECT PER INSPECTOR REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43692	18041-10000-01413	3026 S FIGUEROA ST	90007	9	120A203    72	5123020025	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.02425	-118.27827	ENERGY ONLY PC FOR TI/ALTERATION OF EXISTING FAST-FOOD DRIVE THRU RESTAURANT TO A STARBUCKS. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT. TOTAL AFFECTED AREA IS 2714 SQ.FT.B#17016-10000-38471	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43693	13041-20000-14791	13279 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.2 KW USING 15 MODULES MICROINVERTER ENPHASE M215 STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43694	11041-10000-01636	20841 W DEVONSHIRE ST	91311	12	204B109   151	2706015005	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.00	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	01/31/2011 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	ADDRESS	34.25741	-118.5878	Ti in an existing snack shop. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43695	14041-20000-32689	5806 N BUCKNELL AVE	91607	2	174B169   214	2339007020	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.17612	-118.39183	pv1install roof mounted pv system sized 4.3kw interconnected with msp.(20) sunmodule sw 250(20) enphase 215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43696	14041-20000-22049	12216 W CANTURA ST	91604	2	162B165   374	2369005046	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.14214	-118.39937	ENPHASE M215PV1 SFD. USING MICROINVERTER. STANDARD PLAN. SYSTEM SIZE 5.1KW AC. USING 24 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43697	18041-10001-42237	11135 W WEDDINGTON ST	91601	2	171B173  1413	2350015115	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.1671	-118.37381	SUPPLEMENTAL CHANGES TO APPROVED SET CHANGES TO RELOCATING OF LIGHTING  CONTROLS, TITLE 24 SQFT REDUCED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43698	17041-10000-15418	4847 W OAKWOOD AVE	90004	4	138B193   216	5522030003	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			05/18/2017 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	12/15/2020 12:00:00 AM	ADDRESS	34.0774	-118.31305	PC FOR POWER AND ENERGY FOR A 4-STORY, AND 49-UNIT APARTMENT. SCOPE INCLUDES (12) TYPICAL UNITS; SERVICE RATED AT 120/208V, 3-PHASE1600 AMP.  B# 16010-20000-03296	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43699	11041-20000-20225	6077 W 3RD ST	90036	5	138B181  1302	5512010016	C1-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.07045	-118.35292	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43700	15041-10000-02172	7340 N KELVIN AVE	91306	3	186B109   811	2113014034	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.20394	-118.58615	PV1 standard plan with 6kw roof-mounted system including (20) Sunpower SPR-327NE modules and (1) Powerone PVI-6000 inverter.Note. applicate was notified for online service, but insisted  to do plan check over the counter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43701	13041-20003-10721	24015 W NORDHOFF ST	91311	12	195B113    79	2781001052	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.23202	-118.57795	Supplemental description: Change to wire size. Original work description:  New fire alarm system for 2-story commercial bldg.  49 devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43702	14041-20000-01009	13645 1/2-1/4 W FOOTHILL BLVD	91342	7	222B157    79	2509015035	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.30793	-118.43064	T24 FOR NEW RETAIL STORE. TOTAL LOAD DOES NOT EXCEED 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43703	16041-10000-44582	1660 W BEVERLY BLVD	90026	13	135A207   240	5153012003	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.06404	-118.26497	Plan check for power and energy. Full build out, going from core and shell to Interior TI office plus an addition of a small lounge office room on 3rd floor. Methane zone area. New Service rated at 1200 A 208/120V 3phase 4Wire. All new equipment as reflected on single line. Total Area: 20310.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43704	12041-10000-01324	11288 W VENTURA BLVD	91604	2	162B173   529	2378010037	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	02/08/2012 12:00:00 AM	ADDRESS	34.14039	-118.37578	Title 24 and emergency lighting for ti in an existing restuarant. not a high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43705	15041-10000-36058	5536 N FULCHER AVE	91601	2	174B173  1122	2350003060	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			10/29/2015 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	07/02/2021 12:00:00 AM	ADDRESS	34.17103	-118.37291	Full plan check for a new 36-units 5-sotry apartment building; Scope includes a 1600-Amp services 3-phase 120/208V. Total (7) typical unit panels, and T-24 for in/outdoor lighting is 32,850-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43706	14041-10000-17369	12558 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	33.97812	-118.41195	PC FOR POWER AND ENERGY. NEW Type VA  6-unit  4-story  APARTMENT BUILDING with attached parking.1 PANEL AND 27  DEVICES.BUILDING APP# 14010-10000-01302	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43707	13041-10000-34233	12130 N BELLANDO CT	91344	12	219B125    91	2601073020	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.29435	-118.52546	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STD PLAN. 8KW DC .(32) SOLARWORLD 250W BLK(32) ENPHASE M215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43708	19041-10000-17796	515 S FLOWER ST 30TH FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC (ENERGY ONLY) FOR UPGRADES FOR NON STRUCTURAL EXISTING COMMON RESTROOMS, ELEVATOR LOBBY, RELATED CORRIDOR AND DOORS. AREA OF SCOPE IS 3,061 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43709	16041-10000-42335	9423 N OSO AVE	91311	12	198B113    93	2748022064	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.24146	-118.57556	PC for energy only. Replace outdoor fixtures with new LED fixtures. Total sqft = 18000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43710	16041-20001-36940	2783 W FRANCIS AVE	90005	1	132A201    90	5077021014	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			07/02/2019 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	34.05694	-118.28632	7/2/2019changes to an approved set of plans.  changes to add fire pump, downsize elevator ratings, revisions to existing lighting controls.((((FULL PC FOR POWER AND ENERGY FOR A NEW 6 STORY 50 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW 1600A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW SUBPANELS, NEW RECEPTACLES, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 43605 SQ. FT.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43711	14041-20000-35834	5161 N LANKERSHIM BLVD	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.16452	-118.37469	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43712	17041-20003-42736	8401 N VAN NUYS BLVD #15	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.22308	-118.44896	05-02-2018 Changes to an approved set of plan, Changes include single line diagram configueroation and update new panel HS New. Changes has been clouded as delta D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43713	08041-20001-17462	6701 N VARIEL AVE	91303	3	180B105    29	2148030031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM			PC Approved	08/27/2010 12:00:00 AM	PIN	34.19201378	-118.59353822	Revision to approved set of plan. Change was adding CO monitoring system on existing branch ciruit. parking structure green building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43714	17041-10000-09738	510 S BURNSIDE AVE LOT A & K	90036	4	135B181   237	5509005014	R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.06599	-118.35011	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 59650 SQ. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43715	16041-20000-21770	7875 N FULTON AVE	91605	2	189B157   599	2303004003	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.21374	-118.4208	$0 permit fee is due to State Senate Bill SB 1222. PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43716	14041-10001-22919	5924 S SAN PEDRO ST	90003	9	105B205   210	6006029026	[Q]MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	33.98677	-118.26941	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 3.06 KW DC ROOF-MOUNTED SOALR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(12) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43717	15041-10000-09908	14827 W VICTORY BLVD	91411	6	180B149   786	2236020017	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	12/01/2022 12:00:00 AM	ADDRESS	34.18681	-118.45621	PC FOR POWER AND ENERGY. NEW 4 STORY, 9 UNITS APARTMENT BUILDING WITH ONE LEVEL SUBTRAINIAN.  3 TYPE APARTMENTS. TOTAL AREA 12003 SQ FT. ACTUAL AREA FOR T24 IS 4201 SQ FT.TITLE 24 SHEETS HAVE BEEN ADDED FOR PARKING LOT, MISSING TITLE 24 SHEETS FOR COMMON AREAS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43718	11041-10000-03100	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian, Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	01/17/2012 12:00:00 AM	ADDRESS	34.07196	-118.24719	adding a 300 KVAR capacitor to a 4000 ampere switchboard for power factor adjustment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43719	14041-20001-10967	15715 W MARILLA ST	91343	12	201B141   320	2671005002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.24749	-118.47439	Fee for expedite only****Roof mounted PV system with Optimizers and transformerless inverters,  system size 9KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43720	19041-20000-26315	16748 W ARMSTEAD ST	91344	12	213B137   280	2610012003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.28201	-118.49733	Plan check for a PV1 roof-mounted PV system. System size is 10.05 kWdc/8.54 kWac-CEC and consists of (30) modules, (30) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43721	14041-20000-22141	20436 W HAMLIN ST	91306	3	180B109   415	2136022015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.19032	-118.57828	PV1Microinverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.74kW(36) EnPhase M215-IG microinverters(36) Hyundai HiS-M250MG pv modulesMain breaker was derated.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43722	16041-20000-38631	"21215 W BURBANK BLVD Bldg ""E""-5th Floor"	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.17353	-118.59268	Plan check for Title 24 only. Project site is the corridor and the elevator lobby on the 5th floor of a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,706 sq. ft.Note: Building application has been created under 16016-20000-23269	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43723	14041-10000-06473	9892 N ARLETA AVE	91331	6	201B153   169	2645009055	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.25013	-118.43432	PV1, INSTALL7.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH  MAIN SERVICE PANEL.(29) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-6000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43724	17041-10000-20496	6060 W HOLLYWOOD BLVD	90028	13	148-5A189 153	5545006030	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.10148	-118.32207	Title 24 plan check.  T.I. and change of use in 2 story commercial building from retail/restaurant to office.  New 400 amp service.  Total area = 4,681 sq. ft. (indoor) + 972 sq. ft. (outdoor)       Building permit #17016-40000-11249	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43725	10041-20000-03285	400 S HOPE ST 12th Floor	90071	9	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	06/25/2010 12:00:00 AM	ADDRESS	34.05199	-118.25366	T-24 AND EMERGENCY LIGHTING PLAN CHECK ONLY for the 12th floor remodel.  Less than 400 amperes of load added to the existing system.  Excess plan check submittal fees abandoned at the applicant's request to forego full plan check at this time.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43726	15041-20000-34623	3740 S WASATCH AVE	90066	11	114B153  1315	4246023018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	11/07/2015 12:00:00 AM	ADDRESS	34.00469	-118.43666	PV1. NEW SOLAR SYSTEM ON A RESIDENTIAL ROOF TOP. TOTAL SYSTEM SYSTEM IS 5520 WATTS AC. (STANDARD PLAN)(23) MODULES-LG 305NC-B3 MODULES(23) ENPHASE ENERGY MICRO INVERTER m250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43727	18041-20002-01681	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.06047	-118.29555	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE ADDING 9 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43728	15041-20000-17730	12418 N GLADSTONE AVE	91342	7	219B161   241	2525019066	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	PIN	34.29583071	-118.4110579	Plan check for Title 24 only for general T.I. for future industrial space. Total area: 11,720 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43729	14041-10000-06133	7906 S NARDIAN WAY	90045	11	099B157    84	4113022028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	33.96646	-118.42043	PV1,INSTALL5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(21) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43730	15041-20000-17238	14859 W BESSEMER ST #6	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	34.18089	-118.45722	Plan check for Title 24 only retail space. Total area:1450 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43731	16041-20000-00389	13420 W SATICOY ST	91605	2	186B157   183	2303024011	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.20861	-118.42526	Plan check for New fire alarm system(Rescue Mission San Fernando). Total devices:33.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43732	14041-10001-33787	865 S FIGUEROA ST	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM			PC Approved	03/09/2015 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for express permit 14041-10000-33787 per inspector request.  Scope of work is for (8) new level 2 EV charging stations, 75 kVA XFMR, and (1) new panel.  (((ELECTRIC CAR CHARGER (4) CHARGING STATIONS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43733	19041-20001-01448	16243 W BERMUDA ST	91344	12	207B137   235	2680008007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	34.26638	-118.48624	Expedite per applicant request Plan check for PV roof mounted system with energy storage system(ESS), System size: 3.8KW AC, 2.97KW DC, with  9 PV Modules, 1 inverter(3.8KW), and Tesla PowerWall 2.0 13.5KWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43734	19041-20001-30690	16633 W VENTURA BLVD #1200	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Approved	08/29/2019 12:00:00 AM	ADDRESS	34.15823	-118.49571	08-29-2019 changes to an approved set of plan, Changes include remove exit signs. Changes has been clouded as delta 1. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43735	15041-10000-43901	19519 W ENADIA WAY	91335	3	183B117   106	2130006010	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.20026	-118.55861	PV1 SFD TOTAL SYSTEM SIZE 2.64KW AC USING MICROINVERTER SYSTEM. ENPHASE M250. NONSTANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43736	12041-20000-19790	14062 N BALBOA BLVD	91342	7	228B137   186	2603007027	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM			PC Approved	08/22/2012 12:00:00 AM	ADDRESS	34.32065	-118.4882	T.I. for an existing on first floor and meezzanine.  Install new general/emergency lighting in the office and storage areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43737	14041-10000-33746	12368 W HALEY ST	91352	6	195B165    98	2629018014	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.23398	-118.40239	PV1 roof mounted system size: 6kW with 1 inverter(ABB PV1-6000-OUTD) and 26 modules(kyocera KD255GX-LFB3). FEE AMOUNT REFLECT ON SENATE 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43738	18041-10000-16909	500 S VIRGIL AVE #101	90020	13	135A201    62	5077005030	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.06492	-118.28687	TI IN AN EXISTING MEDICAL OFFICE BUILDING (OSHPD 3) IN SUITE #101 ON THE 1ST FLOOR.  PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT # 18016-10000-10313	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43739	17041-10000-23747	5701 S CRENSHAW BLVD	90043	8	108B185   662	5006004001	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.99059	-118.33115	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43740	12041-10000-03411	515 S FIGUEROA ST 20th&21st-floors	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	ALTERATIONS IN OFFICE SPCES PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43741	18041-10000-03472	14610 W VALERIO ST	91405	6	186B149   568	2218016008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.20472	-118.45146	New PV1 rooftop solar system on SFD, system size is 10kW AC. (30) modules with power optimizers, (1) inverter	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43742	17041-10000-34082	110 S VAN NESS AVE	90004	4	138B189  1028	5516011009	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.0726	-118.31547	PC FOR NEW INSTALLATION OF TESLA  POWERWAL 2 IN SFD. SCOPE INCLUDES TWO NEW BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43743	14041-20000-33202	1429 S OGDEN DR	90019	10	129B177   639	5068022038	R2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.05028	-118.36485	Roof mounted PV system with Enphase microinverter, model M215-60 series.  Total system size 3.12KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43744	15041-10000-00994	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Closed	10/21/2015 12:00:00 AM	ADDRESS	34.1504	-118.32742	PC FOR POWER.INSTALLATIN OF A TEMPORARY POWER SUPPLY FOR CONVEYOR SYSTEM(MEDIUM VOLTAGE).***approved by John per F.Y***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43745	16041-10000-38961	464 S LUCAS AVE	90017	1	132A207   157	5152002027	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.05608	-118.26277	Title 24 plan check.  Remove HID fixtures and replace with LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43746	15041-10000-35831	11111 W CUMPSTON ST	91601	2	174B173  1268	2350003012	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			10/26/2015 12:00:00 AM			PC Info Complete	01/12/2016 12:00:00 AM	ADDRESS	34.17011	-118.37286	NEW 4-STORY (TYPE III-A) 46 UNIT APARTMENT OVER 1-STORY AND BASEMENT (TYPE 1-A) PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43747	11041-10000-13140	1056-1062 E ELKGROVE AVE BLDG 19	90291	11	111B145   391	4243001036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.00222	-118.45914	alterations and renovations of 11-units apartment buildingvariance is required to separate theFire Alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43748	19041-10001-08751	10101 S BROADWAY	90003	8	091-5A203 235	6053024019	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Approved	03/22/2019 12:00:00 AM	ADDRESS	33.94445	-118.27854	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 30.24KWdc / 28.8KWac.(84)MODULES-JINKO SOLAR JKM360M-72V(2)INVERTER- SOLAREDGE SE14.4KUS(24)OPTIMIZERS-SOLAREDGE P730(18)OPTIMIZERS-SOLAREDGE P850	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43749	15041-10000-18739	12492 W OSPREY LANE 1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'B'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'B' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43750	16041-10000-44701	508 N AVENUE 50	90042	1	151-5A225 288	5471021011	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1851.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.1088	-118.20507	PV1, INSTALL NEW 4.505 KW DC ROOF-MOOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (17) MODULES: AXITEC AXIPOWER AC-256P/156-60(1) INVERTER: FRONIUS  PRIMO 5.0-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43751	16041-10004-39052	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	PC FOR CHANGES TO APPROVED PLAN UNDER DELTA 4 ONLY.SCOPE INCLUDES RELOCATION OF  IT  ROOM INCLUDING LIGHTS AND RECEPTACLES. REUSING SAME CIRCUITS. REVISION TO T-24 FORMS TO REFLECT CHANGES. THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER ORIGINAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43752	17041-20002-04134	1800 N VINE ST	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM			PC Approved	02/24/2017 12:00:00 AM	ADDRESS	34.10393	-118.3265	02/24/2017 Changes to an approved set of plans. All changes have been clouded. Changes were made to the single-line diagram and the lighting floor plans. Location and power rating of (1) UPS has changed and existing lighting fixtures from garages have been omitted from lighting floor plan to eliminate confusion over scope of work.*****Previous Work Description*****(2/8/2017)replacement of lost plans. addition of (2) UPS 4.8kva to an existing commercial office building non-high rise. adding em lighting with new circuits.  this application to include general lighting for bathrooms and garage/garage lobby only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43753	14041-10002-21186	2718 S FIGUEROA ST	90007	9	121-5A203 129	5123018032	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM			PC Approved	02/23/2015 12:00:00 AM	ADDRESS	34.02678	-118.27665	DELTA 6 CHANGES TO APPROVED SET OF PLANS- A DRAWING OF THE LCP AND ITS WIRING  DIAGRAM WERE ADDED TO THE REVISED PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43754	13041-10000-27957	15301 W VENTURA BLVD STE U5	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.15411	-118.46654	Dental office TI in Sherman Oaks Galleria.  Healthcare facility per NEC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43755	17041-10001-24630	8471 W BEVERLY BLVD Suite #101	90048	5	138B173   428	5514012025	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.07621	-118.37572	Changes to an approved set of plans, changes are noted on delta 2. Changes include the addition of light fixtures and low voltage wiring plan check for energy only, T-24.  _________________________PC for T24 for retail TI. PC for new lighting. Total area is 3003 sqft. Load under 400A. Installing new circuits and equipment. building #17016-10000-19969 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43756	13041-10000-26350	6643 N RIVERTON AVE	91606	2	180B177    64	2414026045	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.19154	-118.36608	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A STANDARD PLAN ; COMBINER BOX USED. SYSTEM SIZE IS 6.75kW DC WITH (27) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG 5100 NEG	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43757	18041-10000-18529	15350 W OXNARD ST BLDG B	91411	4	177B145   462	2243001031	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	11/16/2020 12:00:00 AM	ADDRESS	34.17919	-118.46783	"NEW THREE STORY BUILDING WITH ASSOCIATED SITE WORK (PARKING, LANDSCAPING, LIGHITING) SELF-STORAGE BUILDING ""B"". SCOPE OF WORK: NEW 1,600A SERVICE (MSB) (Located on the side of Bldg ""A"") feeding power to Existing (MDP-A) with all existing loads to remain in Bldg ""A"" and the new (MDP-B) with all new loads in Building ""B"", TOTAL AREA 138,245 SQ.FT (INDOOR + OUTDOOR SITE)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43758	17041-20000-31095	2570 W PICO BLVD	90006	1	129B197  1114	5075005006	[Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.04704	-118.29372	service upgrade 600 amp to an existing multi-tenant building.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43759	16041-10000-15700	526 W 76TH ST	90044	8	099B201   112	6020020008	[Q]R3-1	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	33.97059	-118.28368	PV1, NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. SCOPE INCLUDES 27 MODULES(SC-265) AND ONE 6KW INVERTER(ABB PVI-6000). TOTAL SYSTEM SIZE = 6KW(AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43760	13041-10001-03981	2626 E 25TH ST	90058	14	117A219   147	5168023009	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM			PC Approved	11/25/2013 12:00:00 AM	ADDRESS	34.0152	-118.22477	][][]CHANGES MADE TO AN APPROVED SET OF PLANS TO (E) INDUSTRIAL FACILITY; CHANGES IS TO ACCOUNT FOR THE USE OF NEW CABLE TYPES FROM TYPE MC-HL (XHHW-2) TO TRAY CABLE-POWER CABLE; APPROXIMATELY 10000 FT OF LENGTH WILL BE AFFECTED. ][][][][]PLAN CHECK NOTE: ASSIGN THIS PARTICULAR PLAN TO FRANCIS PER FRANCIS' REQUESTORIGINAL DESCRIPTION::REPLACEMENT OF 480V DISTRIBUTION SYSTEM. RATED AT 4000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43761	18041-10000-27173	1432 N TAMARIND AVE	90028	13	147A191   124	5545015041	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Issued	09/14/2018 12:00:00 AM	ADDRESS	34.09661	-118.31892	PLAN CHECK FOR POWER AND ENERGY FOR 4 STORY 21 UNIT APT WITH BASEMENT GARAGE. SERVICE SIZE = 2000A AT 120/240V. TOTAL AFFECTED AREA 20088SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43762	16041-20000-14499	10447 N HADDON AVE	91331	7	207B157  1238	2646007006	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.25994	-118.42778	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3kW. Ungrounded system. (10) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43763	15041-20000-08646	13571 W VAUGHN ST	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Expired	02/13/2018 12:00:00 AM	ADDRESS	34.27758	-118.42846	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.Plan check for PV system 1986.77kW. Roof top mounted system 6514 modules(Renesola JC305M-24/AB) and 57 inverters. (solectria PVI25TL 480V). PV system is a feed and tariff system.Note: Fire stamp is needed prior approval	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43764	13041-10000-36156	1135 S SAN JULIAN ST	90015	14	124-5A209 345	5145024***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.03511	-118.25397	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43765	17041-10000-37325	8016 W 3RD ST	90048	5	138B177   762	5511028027	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.07178	-118.36439	RESTAUANT TI for change of use from Church to Restaurant, Scope of work includes new lighting and receptacles with a new panel. Total Sq. ft. 1519.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43766	18041-10000-43357	6031 N CRANER AVE	91606	2	177B173   981	2414004014	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Apartment			11/13/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.18029	-118.36933	FULL PC FOR NEW 2-STORY 6-UNIT TYPE V-B APARMENT BUILDING PER ZA-2017-4514-ZAA WITH 10 UNCOVERED PARKING STALLS PROVIDED, T24, TOTAL OUTDOOR SQFT 5000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43767	13041-10000-09591	5020 W WILSHIRE BLVD	90036	4	132B185    14	5507028029	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	34.06191	-118.33886	RENOVATION OF EXISTING STARBUCKS. NO CHANGE OF USE. NEW LIGHTING PLAN AND SOME NEW EQUIPMENT. TOTAL AREA OF NEW WORK 1500 SQ FT. PC FOR ENERGY ONLY. T24. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43768	14041-20000-05155	12698 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	33.97714	-118.41552	PC FOR SERIES OF ROOF-MOUNTED,PHOTOVOLTAIC SYSTEMS FOR NEW CONDOS. THIS SYSTEM IS SPECIFIC FOR UNIT 3. SYSTEM SIZE 3KW AC. SYSTEM IS TIED TO MAIN SERVICE SERVING OTHER UNITS. THIS IS PLAN CHECK AND PERMIT SUBMITTAL 3 OF 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43769	18041-10000-36057	10250 W CONSTELLATION BLVD CORRIDOR-16TH FLOOR	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	PLAN CHECK FOR T24 ONLY,  TI IN A 16TH FLOOR CORRIDOR OF (E) COMMERCIAL BUILDING. TOTAL AREA: 1,796 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43770	14041-20000-09791	555 W 5TH ST FLOOR 33	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI in 33rd floor corridor space for commercial office building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43771	17041-20001-39235	17455 W FLANDERS ST	91344	12	213B129   188	2607009010	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.28065	-118.5138	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.075 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43772	18041-10000-27073	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.04166	-118.26677	INSTALL A 12.5KW UPS FOR THE SMOKE CONTROL SYSTEM IN A NEW APARTMENT BUILDING (PER INSPECTOR'S REQUEST).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43773	19041-10000-48847	789 N FRONT ST	90731	15	021B201    98	7448036021	M1-1VL-CPIO	Harbor	San Pedro	Central San Pedro	YES	2962.10	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Issued	11/26/2019 12:00:00 AM	ADDRESS	33.7512	-118.28657	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43774	10041-10000-12973	3502 S WATT WAY Room #227	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.02207	-118.28645	TI in an existing commercial area of the USC in Room # 227. Plan Check is for Title 24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43775	11041-10000-04461	1472 S CARDIFF AVE	90035	5	129B169   174	4306005010	R2-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	ADDRESS	34.05309	-118.39195	NEW PV SYSTEM FOR A SFD. EPC IS FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43776	12041-10000-26711	738 E 12TH ST B	90021	14	123A211    36	5132012035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.03297	-118.25214	PLAN CHECK FOR ENERGY. 1 STORY. TI EXISTING BUILDING 2055 SF. LOAD LESS THAN 100A.  PERMIT WAS PULLED UNDER 12041-10001-26711.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43777	15041-10000-13665	6040 W CENTER DR 1-218	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	33.97574	-118.39042	install new addressable FA system to new mixed used apartment, 218 units , 6 story. 665 fa devices, 24 fa panels.fee per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43778	14041-10000-16047	10940 W WILSHIRE BLVD suite 1550	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.05822	-118.4452	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. OFFICES. 15TH FLOOR. SUITE 1550.  4333 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43779	19041-10000-34935	3827-3841 W WASHINGTON BLVD	90018	10	126B185   942	5072014002	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	08/05/2022 12:00:00 AM		Issued	08/05/2022 12:00:00 AM	ADDRESS	34.04004	-118.32674	FULL PLAN CHECK, SCOPE INCLUDES NEW 1600A SERVICE, THAT FEEDS A 600A HOUSE BUS AND A 1200A SWITCHBOARD. THE SWITCH BOARD SUBFEEDS VARIOUS 200A PANELS. THERE IS ALSO A 80KW STANDBY GENERATOR FEEDING A 400A BOARD. B#19010-10000-03834FIRE ALARM VARIENCE HAS BEEN SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43780	12041-10000-23078	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Public Safety Only			09/27/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	New fire alarm systam for suite # 195 @ Century City Mall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43781	14041-10000-09088	2040 N COMMONWEALTH AVE	90027	4	150B201   432	5591009021	R2-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.10885	-118.28511	PV1, Install 2 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE3000A-US-ZB-U.(8) Modules: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43782	11041-10000-03759	3103 S LA CIENEGA BLVD #A	90016	10	123B173  1531	4205035013	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM			PC Approved	03/08/2011 12:00:00 AM	ADDRESS	34.02996	-118.37335	Ti in an existing office. EPC is for T24 & Emergency lights. (Mossimo space)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43783	19041-20000-41206	20827 W PINECONE CIR UNIT #20	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.29589	-118.58784	PV roof mounted system, PV system size: 4.2KW wiht 12 AC Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43784	16041-20000-45121	431 S BROADWAY	90013	14	129A211    39	5149026003	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Info Complete	01/18/2017 12:00:00 AM	ADDRESS	34.04886	-118.25023	New 2000A 120/208 3ph-4w service for (E) 3-story commercial building.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43785	17041-10000-20590	1888 S CENTURY PARK EAST #1625	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.06104	-118.41402	Title 24 plan check.  T.I. to office space in existing commerical highrise building.  Subpanels to remain existing with new lighting and receptacles.  Lighting area = 2,628 sq. ft.       Building permit #17016-10000-16258	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43786	13041-10002-26021	12665 W VILLAGE LANE block 5	90094	11	105B161  1220	4211034054	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	33.97786	-118.41484	DELTA 14 CHANGES TOR PERMITTED SET OF PLANS; CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA 14 CHANGES((((((((PLAN CHECK FOR POWER AND ENERGY. THIS IS BLOCK 5 OF PLAYA VISTA PROJECT. E	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43787	12041-10000-16010	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.05436	-118.25543	Plan check T24 Energy/Emergency lighting for new corridor light fixtures from 4 thru 12th and 14th floor. Existing area controls and branch circuits. No T24 Energy plan check for the guest rooms. Permit for new fixtures in corridor and guestrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43788	11041-10000-26228	2513 N WESTRIDGE ROAD	90049	11	141B133   191	4492020019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.08155	-118.50755	PLAN CHECK 8.64KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43789	13041-20000-02632	21300 W SHERMAN WAY SPC #3-SPC # 4	91303	3	183B105   211	2112027013	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	34.20077	-118.59568	Full plan check for medical clinic. General care only. Space #3 and #4. 1130 sqft. Low-rise commercial.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43790	18041-20002-04532	6800 S AVALON BLVD	90003	9	102B205   234	6007019019	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Closed	10/30/2020 12:00:00 AM	ADDRESS	33.97824	-118.26497	06-20-2018 Changes to an approved set of plan. Changes include add general lighting to space 6800 and 6802. All changes has been clouded. *****************Proviouse work description****************************4/19/18changes to an approved set of plans.  changes noted delta 1.  changes to add new transformers and associated panels with no loads.  change feeder type from CU to AL.  ((((2) new services 1200 amp each serving an existing commercial building.  plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43791	13041-20000-01787	2141 W CLINTON ST PV-1	90026	13	138A207    10	5402038020	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Expired	05/20/2015 12:00:00 AM	ADDRESS	34.07425	-118.26705	Plan check for PV system. Transformerless system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43792	15041-10000-09127	12025 W VOSE ST # 6	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.19855	-118.3952	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 810 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43793	15041-10000-39580	12665 W VILLAGE LANE	90094	11	102B161  1257	4211034064	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	33.97786	-118.41484	"ONE  ILLUMINATED LEDs  WALL SIGN FOR LEASING OFFICE 18"" X 7'- 8""plan chk is for title 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43794	14041-20001-11153	6600 N TOPANGA CANYON BLVD # 1084	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	09/05/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	Modifications to approved set.  Changes to proposed lighting system.T.I. EXISTING RETAIL. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 4600 SQ FT. USING TAILORED METHOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43795	15041-10000-07280	13573 W MERCER ST	91331	7	207B157   562	2619023017	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.2643	-118.42841	PV1 INSTALL  4.905 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(15)MODULES, (1)INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43796	13041-10000-34186	100 S SANTA FE AVE ste #1000	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.04798	-118.23239	Plan check for power and energy. 1st time tenant. TI for  Metrolink office. 6 story mixed use - not high rise. Located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43797	11041-10000-02944	4176 W VENICE BLVD	90019	10	126B185   229	5072003027	C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.04437	-118.32824	New service for soil vapor extraction site. EPC is for power.  The service is 800 ampere 480/277 volt three phase 4 wire, with 10 foot ground rod.  Inspector to verify that the power distribution units are listed by a recognize testing agency.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43798	16041-30000-27700	601 S FIGUEROA ST 4575	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,120 sq. ft. Note: Building applicant has been generated under 16016-10000-16798	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43799	10041-20000-05604	3551 S TROUSDALE PKWY 3RD FLOOR	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	34.02066	-118.28531	INSTALLING LIGHT AND POWER MULTI PURPOSE CONFERENCE ROOM IN USC SCHOOL. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43800	19041-20000-12411	23052 W HATTERAS ST	91367	3	174B097   190	2041016028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.17538	-118.62942	Plan check for a PV1 roof-mounted PV system. System size is 10.15 kWdc/9.01 kWac-CEC and consists of (1) 10 kWac rated inverter and (35) modules.Note: Building permit has been issued under 17014-20000-04755	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43801	14041-10001-27859	11220 S HINDRY AVE	90045	11	087B173   101	4129038019	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	33.93221	-118.37223	PC FOR CHANGES TO APPROVED SET OF PLANS. CHECKING FOR CHANGE TO ISC CALCULATIONS. DWP REPORT SHOWS 39KA AT THE SERVICE. DALL CALCS HAVE BEEN CLOUDED DELTA 3 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43802	13041-10009-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta 1 revisions:REDUCED LOADS ON 1600A BUSWAY AND ON 3000A BUSWAYLOAD CALCULATION FOR EACH BUSWAY WAS REVISED . ALL CHANGES ARE CLOUDED ON NEW PLANS Replacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43803	19041-10001-26931	1320 W 12TH PL	90015	1	127-5A205 140	5137031029	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	02/25/2020 12:00:00 AM		Issued	02/25/2020 12:00:00 AM	ADDRESS	34.04376	-118.27302	Changes to an approved set of plans, changes include the installation of a back up generator and ATS rated at 800 amp. Note changes on clouded areas. ____________________________________________________________________PC FOR POWER ONLY. NEW 300KW TEMPORARY GENERATOR. TEMPORARY POWER FOR FREE STANDING SIGN.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43804	17041-10001-12684	525 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/13/2017 12:00:00 AM	ADDRESS	34.05109	-118.25696	CHANGE TO APPROVED SET OF PLANS. CHANGES NOTED DELTA A. CHANGE TO DEMAND READING. PLANS NOW REFLECT CORRECT METER READING. PC ONLY - PERMIT ALREADY PAID UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43805	12041-10001-14493	14531 W VENTURA BLVD	91403	4	166-5A151 101	2265010022	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM			PC Approved	10/05/2012 12:00:00 AM	ADDRESS	34.15126	-118.44977	Revision to the approved plan. Change the lighting. EPC is for T24 ((((((((((((T.I. to existing building (Restaurant).  Install general/emergency lighting.  Plan check for energy only)))))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43806	14041-10000-02420	25020 S BROADWELL AVE	90710	15	036B197   113	7413018050	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	33.79714	-118.2926	Remove HID light fixtures and replace with new fluorescent fixtures in a storage space.  Title 24 plan check for fixture one-for-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43807	13041-20000-21404	15234 W RAYNETA DR	91403	4	165A147   291	2277013024	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2013 12:00:00 AM			PC Info Complete	10/25/2013 12:00:00 AM	ADDRESS	34.14499	-118.4648	NEW SINGLE FAMILY DWELLING. PC FOR POWER. PER APPLICANT REQUEST. NEW 400A SERVICE. FULL PC PER APPLICANT AND HOME OWNER. NON HAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43808	11041-20000-21888	11611 W SAN VICENTE BLVD	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	T.I.  Remodel of light fixtures for Suite 920.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43809	17041-20000-36751	8544 N VAN NUYS BLVD	91402	6	192B149    81	2638001042	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.22599	-118.44899	Tenant improvement/change of use from retail to arcade.  Plan check for energy - 2672 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43810	12041-10000-09991	8500 W BURTON WAY # 100	90048	5	138B173  1128	4334016087	(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.07095	-118.37677	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT GROCERY STORE (TRADE JOE'S). #100.  THE PERMIT NUMBER FOR THE FIRE ALARM SYSTEM IS 12041-10000-03443.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43811	13041-20001-21714	9671 N VANALDEN AVE	91324	12	201B121   444	2762006002	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM			PC Approved	08/28/2013 12:00:00 AM	ADDRESS	34.24683	-118.54935	((EXPEDITE)) PV1 TRANSFORMERLESS SYSTEM. 30 PANELS AND 2 INVERTERS. TOTAL SYSTEM SIZE 12.0 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43812	16041-20000-40358	2604 S ANCHOVY AVE	90732	15	012B189   548	7563036014	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	33.72508	-118.32142	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (40) modules, (40) micro-inverters, and (1) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43813	12041-10000-18358	6348 N SEPULVEDA BLVD	91411	6	180B145   835	2242010003	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.18618	-118.46591	Plan check for new roof mounted 12.74KW photovoltaic system. Existing Wells Fargo Bank.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43814	16041-10000-05607	7817 N LANKERSHIM BLVD TLC-1	91605	6	189B169   659	2310025031	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.21268	-118.388	T-24, TI TO AN OFFICE SPACES ON TLC-1. SCOPE OF WORK INCLUDES ADDING NEW LIGHTING NO NEW RECEPTALCES. TOTAL SQ. FT. 5522	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43815	14041-10000-10988	5867 S CENTRAL AVE	90001	9	105B209   588	6007003031	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	33.98775	-118.25672	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT CHASE BANK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43816	10041-10000-17513	2311 S FAIRFAX AVE	90034	10	123B173  2062	5064029907	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	08/25/2011 12:00:00 AM	ADDRESS	34.037	-118.36902	INSTALL A 44KW PV SYSTEM ON A 61' x 108' TRUCK SHED ABOUT 20' HIGH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43817	13041-20000-08764	8990 W NATIONAL BLVD	90034	10			M1-1	West Los Angeles				2701.00	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.03085	-118.39063	BAKERY 600 A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43818	19041-10000-51938	1 S LMU DR BUILDING A	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	09/16/2020 12:00:00 AM		Permit Finaled	11/17/2020 12:00:00 AM	ADDRESS	33.96577	-118.42406	PLAN CHECK FOR A FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES 1 CONTROL PANEL, 1 COMMUNICATION DEVICES, 12 POWER SUPPLIES, AND 923 DEVICES*REFER TO COMMENTS FOR ADDITIONAL INFORMATION*	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43819	13041-10001-10268	700 WORLD WAY TERMINAL 7-TempPower	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	33.94286	-118.39982	Plan check only. Temporary power for 4 MCPs (1-4) and corresponding (temporary dist. panel T-DPC).   Power plan check only. Changes on plan include updated service load calcs and wire size change for MCP-101, distribution board load added for reference.see Sasco's scope of work: 14041-10000-12456 (Temporary dist. panel T-DPC and 2 feeders)see Dynalectric's scope of work: 14041-10000-12462 (Dist panel PDP-A3 and PDP-B8 and MPC 101-104)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43820	12041-10000-28821	6922 W HOLLYWOOD BLVD Spc 107	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM			PC Approved	01/03/2013 12:00:00 AM	ADDRESS	34.10137	-118.34103	T.I.  Wetzel's Pretzels to occupy space # 107 which was previously occupied by a Yougurt shop.  Adding some pendant lights to the existing lighting.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43821	15041-20000-26452	10250 W CONSTELLATION BLVD 11th&12th-Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for power and lighting. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. All work being done is on the 11th and 12th floor. Work includes the addition of (1) 225-amp panel, associated loads, and the addition of new load onto existing panels. Total lighting area = 29,636 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43822	15041-10000-01256	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.24317	-118.50383	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 5888 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43823	15041-30001-42257	13123 N CRANSTON AVE	91342	7	222B161    66	2512029074	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	12/24/2015 12:00:00 AM	ADDRESS	34.3087	-118.41607	Expedite fees only.     Addition of new roof mounted solar PV array to existing roof mounted solar PV system on existing single family dwelling.  Total system size = 6.6 kWac (3 kWac new).  Addition of one inverter to existing single inverter system (two inverters total).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43824	16041-10002-16576	6150 W 96TH ST	90045	11	093B165   121	4124027906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	33.94871	-118.39284	PC for changes to approved set under delta 3 Changes includes removing ats powering the restroom and changing MDB to 3Phase 4Wire 120/208V.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43825	14041-20000-20031	8054 N VALLEY FLORES DR	91304	12	189B089    42	2020026009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.2167	-118.64599	PV1Microinverter standard plan.Install roof-mounted solar array on SFD. Interconnect with MSP. System size: 9.245kW(43) EnPhase M215-IG microinverters(43) Yingli Solar YL250P-29B pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43826	19041-10000-49686	21600 W OXNARD ST Suite 650	91367	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.179	-118.6002	T-24 Energy plan check only. Total affected area is 5369Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43827	12041-20000-06625	2121 S AVENUE OF THE STARS #120	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	T.I. to existing high rise building on the 1st floor.  Install new branch circuits and  general/emergency lighting.   Total new added connected load approximately 45A.   Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43828	19041-10000-39587	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Issued	01/17/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	Energy plan check only . scope of work area 909sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43829	14041-10000-29329	13561 N GLENOAKS BLVD	91342	7	228B145   438	2501016015	C2-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.3184	-118.46407	Plan check for Title 24 only. Area = 1809 sq. ft. Installating of new lighting and receptacles in existing office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43830	12041-20000-13620	19755 W VANOWEN ST A-10	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	First time tenant in Suite A-10.  Add approx. 6 outlets.  No light change from the core and shell approved plans.  Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43831	18041-10000-13638	10635 W WILSHIRE BLVD 1-46	90024	5	132B153    69	4360011003	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	34.06138	-118.43484	PLAN CHECK FOR FIRE ALARM SYSTEM - PLAN CHECK CONSIST OF 1 FIRE ALARM PANEL AND 148 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43832	19041-20000-37055	11211 N SEPULVEDA BLVD lot #45	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	08/09/2021 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 4.09 KW ROOF MOUNTED PV SYSTEM WITH (13) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43833	15041-10000-00548	19800 W VENTURA BLVD	91364	3	174B117   369	2164011027	(T)(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.17216	-118.56413	New fire  alarm system for orchard store. 53 devices and one panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43834	15041-10000-37158	1017 N MANZANITA ST	90029	13	145-5A201 477	5427002006	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Refund in Progress	06/27/2016 12:00:00 AM	ADDRESS	34.09114	-118.28251	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(6) KYOCERA MODULES 265WATTS(1) PVI 3.0KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43835	19041-20000-22248	22135 W ROSCOE BLVD LOT #37	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD.  SYSTEM SIZE IS 2.17 KW DC/1.68 KW AC.  SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43836	14041-20001-01337	21312 W MULHOLLAND DR	91364	3	162B105    46	2173018002	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/27/2014 12:00:00 AM	ADDRESS	34.14373	-118.59754	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS USING OPTIMIZERS 12.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43837	13041-10000-21434	11870 W ROSCOE BLVD	91605	6	192B169   488	2310005015	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	PIN	34.22127668	-118.39232387	PLAN CHECK POWER AND ENERGY FOR TI OF EXISTING GAS STATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43838	13041-20000-23955	11881 W LINDBLADE ST	90230	11	108B161    78	4218004018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	33.99563	-118.41468	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10KWAC. 27 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43839	12041-10001-24769	7703 W MELROSE AVE	90046	5	141B177   549	5527008028	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.08389	-118.35765	Revision to the approved plan. Reduce track lights and revise the T24 calc. ((((((((((Revision to approved plans. Adding exterior light fixtures and revise emergency lighting circuit. #11041-10000-26842, #11041-10001-26842))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43840	17041-10000-20745	19851 W NORDHOFF PL #102	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Issued	06/20/2017 12:00:00 AM	ADDRESS	34.23624	-118.56649	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43841	15041-20000-40848	5340 S ALLA ROAD # 205	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	33.9773	-118.42567	TENANT IMPROVEMENT WITH NEW DEMISING WALLS AND REPLACEMENT OF WINDOWS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43842	11041-20000-22754	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.27548	-118.56626	Plan check T24 Energy/emergency lighting existing McDonald's inside a Wal-Mart. Permit for new panels, ckts, and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43843	18041-10000-15954	1601 N HILLHURST AVE	90027	4	147B197   462	5542003901	PF-1XL	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.10017	-118.28767	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43844	18041-20000-24996	9007 S RAMSGATE AVE	90045	11	096B169  1079	4125011005	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Apartment			07/26/2018 12:00:00 AM			Verifications in Progress	10/06/2020 12:00:00 AM	ADDRESS	33.95497	-118.3828	"Plan check for power and energy for new 7 story 30 units appartment building with 5 typical units. Total area: 47593 sq ft. B#18010-20000-02327Fire alarm Variance has ""NOT"" been filed"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43845	16041-20000-21094	11606 N DE CELIS PL	91344	12	213B137   387	2610010015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.28127	-118.49588	Plan check for PV roof mounted system. System size: 5.56kW with 17 AC Modules(ACM) connected to sub-panel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43846	15041-20000-27033	20200 W LORNE ST	91306	3	189B113   266	2107017139	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.21706	-118.57305	Plan check for PV roof mounted system. System size: 6.0kW with 28 modules. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43847	15041-10002-27928	17508 W VINTAGE ST	91325	12	204B129   535	2734019009	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.25196	-118.51611	EXPEDITED RSES PLAN CHECK PER APPLICANT.<<PV1, INSTALL 10.46 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: SUNPOWER SPR327NE(2) INVERTERS: ABB PVI-5000-OUTD>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43848	14041-20000-15476	806 N KENMORE AVE	90029	13	141B197   111	5538014013	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.08615	-118.29688	New roof mounted PV system with optimizers and transformerless inverter.  Total system size 9.52KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43849	19041-10000-53688	12751 W MILLENNIUM	90094	11	102B161  1235	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	02/26/2021 12:00:00 AM	ADDRESS	33.9761	-118.41651	FULL POWER & ENERGY PC. FIRST TIME TENANT. CONNECTED TO AN EXISTING 2000AMP 120/208V 3PHASE 4WIRE SERVICE. SCOPE OF WORK INCLUDES INSTALLATION OF NEW PANELS, CIRCUITS & LIGHTS.************************************************************************************PER BUILDING APPLICATION# 19016-70000-36100:CHANGE OF USE RETAIL TO TAKE OUT RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43850	18041-20000-21657	4699 N WHITE OAK AVE	91316	5	168B129   533	2290015022	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.15584	-118.51756	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (55) modules, and (2) load centers. PV system is interconnecting with a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43851	13041-10000-04906	555 S FLOWER ST FLOOR 44	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	T24 FOR EXISTING OFFICE SPACE. RECONSTRUCTION OF SOME FIXTURES. PC FOR T24 ENERGY COMPLIANCE ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 1726 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43852	19041-20000-21285	6060 W CENTER DR 5TH FLR	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.97602	-118.39073	ENERGY ONLY T24 PLAN CHECK FOR TI TO EXISTING HIGH RISE OFFICE SPACE 5TH FLOOR. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 16,488 SFB#19016-10000-15560	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43853	15041-10000-22125	1801 E 41ST PL STE C	90058	9	114A213   137	5116029059	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.00713	-118.24109	REMOVE EXISTING HID LIGHITNG FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43854	19041-10000-06192	14567 W DICKENS ST	91403	4	166-5A151 147	2276001036	[T][Q]RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.15044	-118.45101	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43855	17041-10000-09509	6561 W 88TH ST	90045	11	096B165  1124	4122013007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	33.95739	-118.4036	PC for energy only, outdoor only. Removing HID fixtures and replacing them with new LED ones. Area: 17,900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43856	18041-10000-43841	17920 W RINALDI ST	91344	12	213B129   281	2715018041	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Issued	11/15/2018 12:00:00 AM	ADDRESS	34.2792	-118.52438	Plan check for a 6.4KW AC roof mounted system with (18) AC modules interconnecting through a subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43857	19041-20000-20696	20013 W SATICOY ST	91306	3	186B113   190	2106006003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.20848	-118.56914	PV 1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 8.91KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (27) LG ELECTRONIC PV MODULES WITH P370 OPTIMIZERS AND A SE7600H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43858	11041-20000-19216	600 W 7TH ST # 540	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	12/28/2011 12:00:00 AM	ADDRESS	34.04728	-118.25685	energy plan check suite # 540 data center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43859	13041-10000-13140	20308 W VIA MANTUA	91326	12	219B113   237	2701059029	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.29855	-118.57582	PV1 ROOM MOUNTED INSTALLATION FOR SINGLE FAMILY DWELLING 2 STORY ON STANDARD PLAN. SYSTEM SIZE IS 5.88KW USING 24 MODULES IN TWO STRINGS [MODULES: TRINA SOLAR # TSM-245 PC05 |||| INVERTER: SUNNYBOY 5000 US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43860	15041-10001-00589	12655 W BLUFF CREEK DR	90094	11	102B161  1281	4211037037	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/11/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	33.97565	-118.41332	SINGLE LINE CHANGES. CHANGE FROM COPPER TO ALUMINUM CONDUCTORS. ALL CHANGES CLOUDED DELTA 3 REVISION. RECHECKING NEW AMPACITY AND SHORT CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43861	13041-10000-14984	101-109 S LA BREA AVE BUILDING A-LEVEL 1	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.07338	-118.34425	"methane gas detection system. 1 panel and 22 devicesBUILDING ""A"" LEVEL 1: CHANGE OF USE FROM OFFICE TO RESTAURANT (1449SF). CHANGE OF USE FROM OFFICE TO RETAIL (503SF). CHANGE OF USE FROM OFFICE TO RETAIL (2110SF).  NO CHANGE OF USE TO REMAINDER OF OFFICE SPACE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43862	14041-20001-06248	8533 N CASABA AVE	91306	3	192B113   123	2781010012	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.22552	-118.5765	(((EXPEDITE FEES)))PV1 ROOFTOP MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43863	15041-10000-05838	8631-8635 W 3RD ST #490 West	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	T24 only of a medical space. Total area = 2862 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43864	15041-10003-12895	3640 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM			PC Approved	07/18/2016 12:00:00 AM	ADDRESS	34.01993	-118.37802	CHANGES TO PPROVED SET. CHANGE UNDER DELTA JCHANGE INCLUDES NEW CEILING LAYOUT. UPDATED T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43865	16041-10000-05333	1450 N SAN PABLO ST 4th floor	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.0618	-118.20243	"Teneant Improvement. PC for energy to an eye medical institude (6 story building) being remodeled Scope of work is being done in the 4th floor. Total sq ft  = 16726""OSHPD 3 PROJECT"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43866	16041-10003-36167	2441 S SEPULVEDA BLVD	90064	5	123B153   141	4256010006	(T)(Q)C2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM	ADDRESS	34.0358	-118.43461	4/13/18 CHANGES TO APPROVED SET. ALL CHANGES ARE CLOUDED WITH DELTA 4R.CHANGES IN CORRIDORS AND STAIRWELLS LIGHTING, ADD 14 EVSE CHARGERS, AND REVISION TO UNITS LAYOUT AND RECEPTACLES ARRANGMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43867	18041-20000-17952	20637 W CHESTNUT CIR #271	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.29338	-118.58373	Plan check for a PV1 roof-mounted PV system. System size is 2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43868	14041-20000-20740	11201 N CHALON ROAD Guest-House	90049	5	141B145   149	4369009007	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.08239	-118.46048	Install new 800A and 1200A panels, and 400KVA transformer for a new Guest House.  Plan check for power only.Note: New Main house, Pool house, and Gate house are under  separate permits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43869	13041-20000-16464	5750 W WILSHIRE BLVD STE 525	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.06227	-118.3542	Plan check for energy only. Emergency lighting is existing per applicant. 5th floor of commercial high rise. Suite 525.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43870	14041-10000-21615	1752 W SLAUSON AVE UNIT A	90047	8	108B193  1385	6002001001	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	33.98899	-118.30843	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM NAIL SALON TO RETAIL . 7-11	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43871	16041-20000-13185	20634 W CLARENDON ST	91367	3	174B109   560	2151030054	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.17096	-118.58263	Plan check for an addition of a PV1 roof-mounted 3.6 kWac PV system onto an existing system. PV addition consists of (1) inverter, (17) modules, (1) combiner box, and (1) load center. Total system size is 8.6 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43872	15041-30002-37245	20339 W NORDHOFF ST	91311	12	195B113    59	2781001053	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.23201	-118.57696	"PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA  2 ON PLANS. CHANGES INCLUDE NUMBER OF CIRCUIT BREAKER AND SIZE FOR GENERATOR AND CIRCUIT BREAKER SIZE FOR DISTRIBUTION PANEL ""2DB"" AND CORRECT EXISTING FEEDER SIZE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43873	16041-20000-21810	7267 N COLDWATER CANYON AVE	91605	2	186B161   583	2327016008	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.20293	-118.41396	TI to (E) commercial retail/office space in single-story commercial building.  Plan check for energy.Building permit under 16016-20000-14395.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43874	19041-20001-36647	6301 N GLADE AVE	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18461	-118.60788	Expedite per applicant request. Plan check for Pv roof mounted system, PV system size: 23.925KW DC, 21.3KW AC CEC with 55 PV Modules and 2 inverters(14.4KW and 9.0KW)Applicant reques: %%%%%%%%%%      Plan stay Van Nuys    %%%%%%%Note: This is 12 Buildings on 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43875	17041-10000-14107	7730 N AIRPORT BUSINESS PARK WAY	91406	6	189B137   124	2205009093	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.21104	-118.49518	Plan check for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new led ones.Area: 21500 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43876	16041-20000-01013	2326 E MEADOWVALE AVE	90031	13	144A217    62	5445020022	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.09036	-118.234	PV1.  Installation of rooftop mounted, utility-interactive 4.0 kW PV system. (12) Suniva OPT335-72-4-100 modules with SolarEdge SE3800A-US transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43877	18041-10000-08458	312 S ALAMEDA ST ste 102	90013	14	127-5A215  66	5163010009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.04494	-118.23784	PC FOR OFFICE TI FOR A FIRST TIME TENATNT FOR POWER AND ENERGY. SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS TOTAL AFFECTED AERA 4959 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43878	19041-10000-46512	2211 W JEFFERSON BLVD	90018	10	120B189   650	5052007900	PF-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.02569	-118.31924	NEW FIRE ALARM SYSTEM WITH 50 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43879	17041-20000-41372	11920 W CULVER DR	90230	11	108B161   674	4218020010	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	33.99048	-118.40951	ti to an existing commercisal building.  adding new lighting new controls to existing panels.  plan check for energy indoor/outdoor only.this is plan check only.  permit fees paid under 17041-30000-40333	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43880	15041-10000-11460	25825 S VERMONT AVE PHASE A	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM			PC Info Complete	04/17/2015 12:00:00 AM	ADDRESS	33.78808	-118.29535	EXTERIOR SIGNAGE FOR KAISER PERMANENTE.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43881	16041-20000-25589	1134 S CRENSHAW BLVD	90019	10	129B189   371	5081003016	C2-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Issued	08/19/2016 12:00:00 AM	ADDRESS	34.05178	-118.32436	PV2.  Roof mounted PV system for existing commercial building. System size: 6.4kW with 20 modules and 1 inverter (6.4kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43882	11041-10000-15567	1515 W 259TH ST	90710	15	033B193   123	7411007056	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM			PC Info Complete	08/30/2011 12:00:00 AM	PIN	33.78853695	-118.30341406	T.I.  Existing single story office space.  Replacing all the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43883	16041-20000-07601	625 N NORTH BROADWAY	90012	1	133-5A215 171	5408016001	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Issued	01/13/2017 12:00:00 AM	PIN	34.05963177	-118.24010092	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT.  RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43884	11041-20000-05832	5971 W VENICE BLVD	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM			PC Info Complete	03/24/2011 12:00:00 AM	ADDRESS	34.03865	-118.37272	Per applicant requested, plan chech for a new UPS system and HVAC panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43885	12041-10000-19442	21505 W RINALDI ST	91311	12	210B105   275	2723004020	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM			Verifications in Progress	12/19/2012 12:00:00 AM	ADDRESS	34.27132	-118.59951	PLAN CHECK POWE AND ENERGY. NEW 2 STORY CLASSROOM BLDG (BLD 2) FOR CHARTER SCHOOL (APPLICATION 3 OF 6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43886	14041-10000-06676	12855 W RUNWAY ROAD block 1	90094	11	102B157   395	4211033054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Public Safety Only			03/17/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	33.97556	-118.41956	New fire alarm system. block 1. playa vista.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43887	15041-10003-28594	12346 W VENTURA BLVD	91604	2	162B165   267	2369002021	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM			PC Approved	12/30/2015 12:00:00 AM	PIN	34.14266557	-118.40229057	12/30/15CHANGES TO AN APPROVED SET OF PLANS, SCOPE OF WORK INCLUDES THE REDUCTION AND ADDITION OF FIXTURES AND FIXTURE TYPE. NOTE CHANGES ON DELTA 1. (((PLANCHECK FOR T24 ENERGY ONLY. CHANGE OF USE FROM RETAIL TO NAIL SALON. 1540 sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43888	17041-20000-45158	15656 W HIGH KNOLL ROAD	91436	5	165B141   442	2285008032	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.14594	-118.47555	Plan check for solar pv system w/roof-mounted array on SFD.7.6kW ungrounded system. (34) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43889	16041-10000-37744	2852 W OLYMPIC BLVD	90006	10	129B197   240	5078014001	C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.0524	-118.29622	PC FOR T24 ENERGY ONLY. CHANGE OF USE FROM RETAIL TO JUICE SHOP. TOTAL AREA 1107 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43890	18041-20000-01171	1942 N SAN YSIDRO DR	90210	5	150B157   163	4384030012	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.10647	-118.42415	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (47) modules, (2) load centers, and (2) PowerWalls.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43891	13041-10001-35540	13631 W TERRA BELLA ST	91331	6	201B157   163	2645007006	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	02/04/2014 12:00:00 AM	ADDRESS	34.2499	-118.43016	Expedited RSES plan check per applicant request.{{PV1, Install 3.18 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (12) modules: Suniva OPT265-60-4-1B0.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43892	19041-10000-15395	1001 S TOWNE AVE #107	90021	14	124-5A211 269	5132010049	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.03417	-118.24984	Remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43893	16041-10000-42328	6310 N PLATT AVE	91367	3	180B093   913	2035008021	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.186	-118.64256	PC FOR ENERGY. REPLACE OUTDOOR   FIXTURES WITH NEW LED FIXTURES  TOTAL AREA 24805 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43894	15041-20000-15530	5881 N HILLVIEW PARK AVE	91401	2	174B157    24	2343020013	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.17734	-118.42678	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222Installation of new roof mounted solar PV array.  Total system size = 10.8 kWac.  Central inverter system with 3 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43895	14041-10000-22459	22915 W VICTORY BLVD	91307	12	180B097   434	2038040031	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.1866	-118.62549	PLANCHECK FOR T24 ENERGY. REFRIDGERATOR ROOM IN RALPHS MARKET. 1020 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43896	13041-20000-05924	17167 W SUPERIOR ST PV-1	91325	12	201B133   407	2692013009	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.24678	-118.50792	PV-1. Standard solar plan for single family dwelling. 6000W inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43897	10041-10000-02476	400 S HOPE ST SUITE #200	90071	9	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	02/26/2010 12:00:00 AM		Permit Finaled	05/12/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	TI IN AN EXISTING OFFICE SPACE IN SUITE #200. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS AND EMERGENCY LIGHTS. PERMIT IS FOR INSTALLING NEW LIGHTS ON EXISTING CIRCUITS. VARIANCE WAS FILED TO SEPERATE THE FIRE LIFE SAFETY SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43898	16041-20000-23109	706 W MANCHESTER AVE Bldg D	90044	9	097-5A207 307	6042002031	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Closed	03/01/2017 12:00:00 AM	ADDRESS	33.95986	-118.26272	Plan check for Title 24 only in existing class room Building D. Total area: 1,676 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43899	19041-10000-26820	5317 E YORK BLVD	90042	14	156A227   382	5478003014	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.12031	-118.19996	Energy plan check for a change of used from an auto body repair to restaurant located in a single story building. Scope includes new lighting and equipment for a core and shell only. Total lighting area is 6693-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43900	13041-20000-29804	1500 W PACIFIC COAST HWY A-L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			10/29/2013 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	BUILDING A:   NEW APARTMENT COMPLEX CONTAINING 12 SEPERATE BUILDINGS UNDER THE SAME ADDRESS. (2) 4000A SERVICES. PER APPLICANT REQUEST SUBMITTED AS ONE LUMP SUM. METHANE ZONE, HAS METHANE REPORT.Note: Variance to separate Methane Detection System has been filed.Permit Bld. B is under 14041-20000-06842Bld. C is under 14041-20000-06845Bld. D is under 14041-20000-06846Bld. E is under 14041-20000-06848Bld. F1 is under 14041-20000-06850Bld. F2 is under 14041-20000-06875Bld. G is under 14041-20000-06852Bld. H is under 14041-20000-06853Bld. I is under 14041-20000-06854Bld. J is under 14041-20000-06856Bld. K is under 14041-20000-06858Bld. L is under 14041-20000-06859Bld. Recreation is under 14041-20000-06860	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43901	17041-10000-45423	12333 W OLYMPIC BLVD Bldg 4	90064	11	123B149   503	4259019014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.03189	-118.45753	ENCLOSING SPACE TO CREATE TWO EXECUTIVE OFFICES WITH LUMINAIRES AND RECEPTACLESPLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43902	10041-20000-14876	811 S FEDORA ST 1-6	90005	10	132B197   539	5094017012	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			07/30/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	02/09/2011 12:00:00 AM	ADDRESS	34.05732	-118.29785	firealarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43903	17041-10000-35024	17711 W REVELLO DR	90272	11	126B117   410	4416020017	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.04144	-118.56122	PC for two new powerwalls with 125A load center. Total system size 11.6kW. No PV installed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43904	16041-20003-09655	712 S OLIVE ST Floors 1-7	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.0462	-118.25568	05-22-2019 Changes to an approved set of plan, Changes include increase main switch gear section to 4000A 480/277 Volts and Service Disconnect to 1600A. All changes has been clouded as delta 19.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43905	14041-20000-29676	5416 N NOBLE AVE	91411	4	172-5A147  45	2250012021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.16901	-118.46162	PV1Install roof mounted solar array on SFD. Interconnect with 200A MSP.System size: 3.6kW. One string of(15) EnPhase M250 microinverters(15) SunModule SW 275 MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43906	18041-10000-47776	800 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	33.94305	-118.39757	PLAN CHECK FOR TITLE 24 ONLY FOR OFFICE WITH 475 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43907	18041-20000-40937	1027 W WILSHIRE BLVD	90017	1	130-5A207 127	5143025010	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			10/25/2018 12:00:00 AM			PC Info Complete	10/25/2018 12:00:00 AM	ADDRESS	34.05196	-118.26214	Plan check for 600A Temp Power for construction site with associated load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43908	16041-20000-14651	16508-16514 W ARMINTA ST	91406	6	189B137    47	2205009050	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.21474	-118.493	Plan check for a PV2 roof-mounted PV Feed-In Tariff system. System size is 133.5 kWac and consists of (6) inverters, (539) modules, (1) load center, and (1) transformer.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43909	10041-10000-01562	200 N SPRING ST	90012	9	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	02/25/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.05405	-118.24317	Add new 600amp switchboards to existing 4000amp switchboard for film industry.  Plan check for power energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43910	14041-20000-35860	1642 E 51ST ST	90011	9	111A213   286	5106026013	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	03/07/2015 12:00:00 AM	ADDRESS	33.99653	-118.24407	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.2kW. Ungrounded system.14  327W pv modules across two strings (7+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43911	13041-20000-31717	1235 W BOSTON ST	90026	1	136-5A211 397	5405026012	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Apartment			11/13/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.06646	-118.25276	T24 FOR NEW LOW RISE APARTMENT BUILDING. SCOPE OF WORK IN COMMON AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43912	18041-20000-14489	9810 N ZELZAH AVE	91325	12	201B129   126	2755001019	(Q)R3-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.24898	-118.52309	PV2THIS IS A (2) PART SYSTEM, ROOF MOUNTED AND GROUND MOUNTED SYSTEM.INSTALL ROOF MOUNTED PV SYSTEM SIZED 136KW WITH (2) 50KW INVERTERS (1) 36KW INVERTER AND (536) MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43913	18041-10001-33466	7286 N CIRRUS WAY	91307	12	186B093   625	2027009022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM			PC Approved	09/10/2018 12:00:00 AM	ADDRESS	34.20277	-118.63685	*Zero dollar plan check fee per SB-1222/AB-1414*Revision to approved set to regroup the modules on the roof top, and to revise notes on enphase combiner box on single line. System design remains the same. **This is plan check only, permit is covered under master # 18041-10000-33466**((PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 7.0 KW AC SCOPE INCLUDES 28 MODULES WITH 28 MICROINVERTERS. ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43914	12041-10000-21107	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.06307	-118.2	TI IN THE EXISTING LABS ON THE FIRST FLOOR OF AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  APPLICANT IS REQUESTING PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43915	14041-20000-33434	17844 W ROSCOE BLVD	91325	12	192B129   340	2101009004	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.22077	-118.5224	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.2kW. Ungrounded system.15  327W pv modules across 3 strings (4+5+6).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43916	13041-10000-22144	4970 N CASA DR	91356	3	168B121    31	2176008005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.16045	-118.54855	PV1 3.92KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: SOLAREDGE SE3800A-US] [( 16) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43917	14041-20001-12262	5044 N BAKMAN AVE	91601	2	171B173  1066	2353013019	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			02/11/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.16205	-118.37722	02/11/2016 Changes to an approved set of plans. New circuits have been added to each unit for a washer and a dryer, service size has increased to 1600 amps, and (1) sump pump has been added in the garage. Delta 1 changes.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY . 5 STORY 46 UNIT APT WITH SUBTERRANIAN PKG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43918	17041-20001-26246	17096 W LASSEN ST	91325	12	201B133   228	2692001030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	ADDRESS	34.24921	-118.50475	expeditepv1install roof mounted pv system sized 27.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43919	15041-20001-00664	422 E 107TH ST	90003	8	090A207   369	6063029006	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	33.93921	-118.26657	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.Derating the main breaker to 175A.System size: 8kW (inv1=5kW; inv2=3kW). Ungrounded system.24  327W pv modules across three strings (inv1=8+8; inv2=8)]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43920	14041-10000-18290	1963 N CHEREMOYA AVE	90068	4	150A189    42	5586013015	RD1.5-1XL	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.10712	-118.32063	PV1 4.32KWdc. 240V. microinverter. STD. 2story. Roofmount. [(16) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(16)modules: {solarworld SunModule SW-270 mono}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43921	11041-10000-16986	615 N SANFORD AVE	90744	15	030B209   447	7424019042	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Info Complete	09/19/2012 12:00:00 AM	ADDRESS	33.77816	-118.25068	SERVICE UPGRADE TO 1200 AMPS IN AN INDUSTRIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43922	17041-20000-43875	12243 N WINDMERE DR	91342	7	219B149   884	2507009***	(Q)RD3-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.2939	-118.44983	Plan check for a PV1 roof-mounted PV system. System size  is 5 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43923	17041-20000-20659	806 N GARDNER ST	90046	5	141B181   215	5526004012	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.08557	-118.35311	PV1.  Install 4.16 kW roof mounted, grid tied PV system.  (13) AC modules.  ACM Standard Plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43924	13041-20003-35622	11975 W BLUFF CREEK DR BLDG#5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	33.98224	-118.40247	CHANGE TO FEEDERS. CHANGE FROM COPPER TO ALUMINUM FEEDERS. ALL CHANGES CLOUDED DELTA VE FOR VALUE ENGINEERING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43925	19041-10000-18523	16556 W PARK LANE CIR	90049	11	159B137   588	4490008003	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.12806	-118.49283	Fee is $6.59 per AB 1414. PV1. NEW ROOF MOUNTED 13.73 KWac PV SYSTEM WITH 45 PV Modules (Q-cell 305) with micro-inverters (IQ7-60) ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43926	16041-10000-00934	1541 N VIEWSITE DR	90069	4	147B169   443	5558004023	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Expired	02/08/2018 12:00:00 AM	ADDRESS	34.09959	-118.38291	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.6KW INTERCONNECTED WITH MSP.(35) SILEVO 290 MODULES(2) ABB INVERTERS 3.6/5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43927	13041-10000-13728	1610 N ARGYLE AVE	90028	13	148-5A189 256	5546028012	[Q]C4-2D	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.10017	-118.32503	This a two story motel , adding a new fire alarm panel and 42 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43928	17041-10000-31462	10459 W TUXFORD ST	91352	7	198B177   137	2544014016	A1-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.23764	-118.35908	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL PROPERTY. SYSTEM SIZE 6KVA INVERTER(SOLAREDGE SE7600A-US) WITH 26 MODULES(LG 395N2W-A5) WITH 26 POWER OPTIMIZERS(P405)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43929	18041-10000-35822	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	33.84481	-118.30379	DESIGN BUILD. Full plan check for a office/warehouse TI. Scope include new lighting, and equipment with a total area of 312,000-SQ FT.Note.  fee is based on engineer's calculation of the items on the application form with a precut check.Plan checker verify all  fee prior to final approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43930	10041-10000-16868	1337 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05034	-118.22437	Solar voltaic system installed on the roof of the building.  Consists of   15   modules,  15  A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43931	17041-20001-18541	17738 1/2 W SHERMAN WAY	91335	3	183B129   155	2121018025	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.20081	-118.52005	9.25.2017 - Plan check for energy only. Supplemental permit - changing lighting in barber shop - 833sqft.======INSTALL LIGHT, FAN AND GFI IN BATHROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43932	16041-10000-20450	1918 W 67TH ST	90047	8	102B193   480	6016020011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Expired	07/16/2018 12:00:00 AM	ADDRESS	33.9784	-118.31182	PV1, rooftop solar installation, 3.0 kW Ac system,    (12) KU2656ZPA    (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43933	15041-20001-07307	1048 S LA BREA AVE	90019	10	132B181   763	5084013019	C2-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.05644	-118.34498	06/24/2015 Changes to an approved set of plans. Changes have been made to the fixture schedule, and the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 883 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43934	18041-10000-01619	651 W USC MC CARTHY WAY (GRAB & GO-)	90089	9	120A201    78	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Info Complete	01/17/2018 12:00:00 AM	ADDRESS	34.02135	-118.28288	"PLAN CHECK FOR ENERGY (T24) ONLY. TENANT IMPROVEMENT. TO CREATE A NEW RETAIL GRAB & GO CONCESSION WITHIN AN EXISTING SCHOOL LIBRARY. SCOPE INCLUDES NEW LIGHTING FIXUTRE TYPE ""F1"", BALLAST CONVERSION OF EXISITNG LAMP 'X1' AND RECEPTACLES. ADD LOADS/CURCUITRIES ON (E) PANELS, NEW LOAD < 200A. TOTAL AREA: 580SQ.FT ((B# 18016-10000-01321))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43935	15041-20000-12937	23032 W CALVERT ST	91367	3	177B097   395	2039008029	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.18046	-118.62887	Plan check for a PV1 roof-mounted PV system. System size is 5.3 kWac and consists of (17) micro-inverters and (17) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43936	17041-20000-45589	14630 W SAN JOSE ST	91345	7	207B149   779	2648021019	OS-1XL-O, RA-1-O, RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Re-Activate Permit	08/23/2018 12:00:00 AM	ADDRESS	34.26122	-118.45094	Plan check for solar pv system w/roof-mounted array for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(40) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43937	18041-10000-13949	3661 S 7TH AVE	90018	10	120B189  1539	5044018900	CM-1VL-HPOZ-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.02109	-118.32493	PC FOR REMOVAL OF HID FIXTURES AND REPLACMENT WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43938	18041-10002-26484	10277 W OLYMPIC BLVD	90067	5	129B161    44	4319005070	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.05329	-118.41657	DELTA 2 CHANGES TO APPROVED PLANS. SUPPL. PLAN CHECK FOR 7 ADDITIONAL DEVICES.<<<<<<<<<<<Plan check for a fire alarm system replacement. New device also added. Whole system include (1) fire alarm panel, (2) power supply and (29) new fire alarm devices.>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43939	14041-10000-02573	10861 W WEYBURN AVE PARKING	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			01/29/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.06247	-118.44344	T24 PART 6 ENERGY FOR (E) PARKING STRUCTURE . REPLACING (E) PARKING FIXTURES WITH LED's.  PROJECTED AREA IN LIGHTING WORK IS APPROX. 69,278 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43940	13041-20000-14773	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	PC FOR T24 ENERGY ONLY. SCOPE OF WORK IS FOR ENERGY REDUCTION FOR LIGHTING LOADS. NO POWER PLAN CHECK REQUIRED PER SUPERVISOR. CHANGE IN FIXTURES AND RETROFIT EXISTING FIXTURES. NO RELOCATION. NO WIRING CHANGES. CHANGE IN LTG FORMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43941	10041-20000-18377	1760 N COURTNEY AVE	90046	4	150B177   563	5551012022	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.10333	-118.35738	New 11.5KW P.V. system.  EPC for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43942	19041-20000-22680	9762 N ABREGO CT LOT 10	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.24774	-118.45048	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43943	14041-20000-09539	347 N FORDYCE ROAD	90049	11	138B141   416	4429019032	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.07236	-118.47147	PLANCHECK FOR SINGLE FAMILY DWELLING. TENANT IMPROVEMENT.  NEW 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43944	13041-10000-03512	17641 W ORNA DR	91344	12	219B129    82	2601048006	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.2999	-118.5183	photovoltaic system for single family 2 story dwelling unit. total system size of 9.36kw. using 39 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43945	17041-20001-13029	4123 N ST CLAIR AVE	91604	2	165B165  1154	2367013023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.14553	-118.39993	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43946	15041-20001-41927	375 N LA CIENEGA BLVD Suite 3	90048	5	138B173    80	4337012068	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.07806	-118.37692	12/21/15Changes to an approved set of plans. Adding new lighting, panel and new controls for daylight. Plan check for energy only.(((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from retail to fitness center. Total lighting area = 2,424 sq. ft.Note: Building permit has been pulled under 15016-10000-15144Note: Permit has been pulled under 15041-40000-39581)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43947	19041-10000-53375	5831 W MANCHESTER AVE	90045	11	096B169   483	4125006019		West Los Angeles				2771.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	02/01/2020 12:00:00 AM	ADDRESS	33.96009	-118.38339	NEW PV1 ROOFTOP SOLAR SYSEM CONSIST OF 12 MODULES (Q-CELL 315), 12 OPTIMIZERS (SE P400) AND 1 CENTRAL INVERTER (SE3800H-US). SYSTEM SIZE IS 3.7KWDC AND 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43948	10041-20001-19276	1014 N HIGHLAND AVE	90038	4	144B185   909	5532027013	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM			PC Approved	10/04/2010 12:00:00 AM	ADDRESS	34.08937	-118.33841	Plan check T24 Energy general/emergency lighting for a fire repair building. Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43949	16041-30000-16650	9728 W ARBY DR	90210	5	156B157   427	4385014023	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.12099	-118.4262	Plan check for power. Project site is a new single-family home. Work includes a new 600-amp service, (5) panel boards, and associated loads.Note: Building permit has been pulled under 14010-20000-03437.  Electrical permit fees were collected under this combination building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43950	18041-10001-13115	9719 S MAIN ST	90003	8	093A203   293	6053014013	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Approved	04/25/2018 12:00:00 AM	ADDRESS	33.9476	-118.27403	EXPEDITED PER APPLICANTS REQUEST. PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 33.29 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43951	16041-20000-09612	11549 N BRADLEY AVE	91340	7	213B157   782	2523002902	PF-1VL	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.27984	-118.43009	(N) compressed natural gas fueling facility.  (N) 2000 A 480/277V service.  Plan check for power and energy.  Hazardous classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43952	12041-20000-17208	5250 N LANKERSHIM BLVD	91601	4	171B173   367	2350018086		North Valley				1253.20	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.16668	-118.37545	Change of use from office to medical office (Kaiser Permanente) on the 8th and 9th floor.  Install panels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43953	13041-20003-31716	18131 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	11/13/2015 12:00:00 AM	ADDRESS	34.16596	-118.52824	CHANGES TO APPROVE SET OF PLANS. CHANGE LOCATION OF DPA3 TO SECOND FLOOR, CHANGE OF HVAC EQUIPMENT. LESS UNITS DIFFERENT MANUFACTURE.  ALSO CHANGE IN LIGHTING DESIGN. RECHECK FAULT CURRENT AND TITEL 24 CALCULATIONS. ALL CHANGES HAVE BEEN CLOUDED DELTA E&F REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43954	15041-20000-02112	10920 N WHITE OAK AVE	91344	12	210B129   722	2712013018	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.26917	-118.51946	PV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 14 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43955	19041-20000-41023	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.03 KW DC/1.801 KW AC. SCOPE OF WORK CONSISTS OF (7) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43956	13041-10000-23936	21525 W DEVONSHIRE ST	91311	12	204B105   174	2722007104	P-1, R3-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	09/09/2013 12:00:00 AM	ADDRESS	34.2574	-118.59907	TITLE 24 PLAN CHECK ONLY.  4621 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43957	14041-20000-10180	862 N LEONARD ROAD	90049	11	138B137   296	4494021010	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.07434	-118.48729	PV1.  Install 5.1 kW DC roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43958	17041-10000-23903	10250 W SANTA MONICA BLVD UNIT# 1330	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER AND ENERGY FOR FIRST TIME TI IN RETAIL UNIT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43959	17041-10000-33816	1530 E 25TH ST	90011	9	117A213   182	5118017018	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.01536	-118.24578	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43960	15041-20000-30495	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	33.94955	-118.38342	Plan check for power and Title-24 (energy).  Total area =23226 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43961	10041-20000-04856	10690 N LAUREL CANYON BLVD unit-J	91331	7	207B153   409	2618002026	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM			PC Approved	03/17/2010 12:00:00 AM	ADDRESS	34.26464	-118.43801	lighting in 7 eleven store. This plan check is for title 24 energy only. This plan check has permit on application 10041-20000-02200. This is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43962	15041-20001-28732	11929 W COURTLEIGH DR 1-22	90066	11	111B157  1103	4233018022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	ADDRESS	33.99687	-118.41943	EXPEDITE FEESPV2 COMMERCIAL ROOFTOP. TOTAL SIZE 15KW AC USING 54 MODULES. INTERCONNECT TO HOUSE PANEL OF EXISTING APARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43963	11041-10000-19741	11100 W SANTA MONICA BLVD 11th floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/28/2011 12:00:00 AM	ADDRESS	34.04726	-118.44465	T24 and emergency lighting plan check for a portion of the 11th floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43964	12041-10002-27347	1026 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	PIN	34.02400284	-118.2895744	Small revisions to permitted set of plans. On the plans, revisions are clouded and identified as delta 12  or delta 16.((((((((New construction and rennovation for a commercial building.  Full Plan check.  Site is in a Methane Zone, Level 1 with less than 2 inches (Passive system only).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43965	14041-10000-34390	200 WORLD WAY 224-R	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	plan check for power and energy. Full plan check for a first time tenant   (retail  store) in terminal 2 of  the airport.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43966	16041-10000-11831	1233 S WESTGATE AVE 1-57	90025	11	129B145   977	4263007244	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Public Safety Only			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.04636	-118.46301	new fire warning system for 5-stories apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43967	15041-20001-28733	3003 W LEEWARD AVE 1-67	90005	1	132B197   281	5077017021	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	ADDRESS	34.05885	-118.28935	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 90KW(291) CANADIAN SOLAR CS6XMODULES(3) SMA 24000TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43968	19041-20000-48403	6200 N LANKERSHIM BLVD	91606	2	177B169   350	2335030022	(Q)C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.18332	-118.38554	Plan check for fire alam system. system has 1 FACP and 74 Devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43969	14041-10000-23856	738 S OGDEN DR 1-12	90036	4	132B177   106	5086021015	R3-1	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			09/02/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.0615	-118.35982	Plan check for power and energy for a NEW  12-unit apartment building. 800Amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43970	15041-10000-28503	10802 W AMBAZAC WAY	90077	5	138B149    45	4362007005	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.0779	-118.45114	PC FOR POWER. NEW ELECTRICAL SYSTEM DESIGN FOR  ADDITION OF 3 STORIES TO ONE 2-STORY BUILDING OVER THE BASEMENT. NEW 800A SERVICE.  B# 15014-10000-03806.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43971	18041-20000-01791	16855 W DEVONSHIRE ST	91344	12	204B133   185	2684007020	C4-1VL, QC4-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.25768	-118.50006	Tenant improvement of (E) tire shop.  Replacement of existing interior lights with LED fixtures, new outdoor lighting, and new sign.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43972	19041-20000-38937	14068 N CARLTON LANE	91342	7	231B153   145	2582041***	(T)(Q)RD6-1, QRD6-1	North Valley	Sylmar	Sylmar	YES	1060.10	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.32811	-118.44005	PV1. INSTALL 4.05 KW DC SYSTEM WITH (11) MODULES AND (1) INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43973	14041-10000-16036	1630 N NORTH MAIN ST	90012	1	136-5A219 638	5409013913	UI(CA)	Central	Central City North			2060.10	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.06682	-118.22728	Per�Senate�Bill�No.1222, Fee cap reached, thus fee is $0.<<PV2 59.67KWdc. 240V. negative GND. NONstd. 2story. Roofmount. [(1) inverters: {Satcon Power-gate Plus 50 kw}]. [(234)modules: {ZN SHINE ZXP6-60-255/P}] connected with (E) solar installation  on solar subpanel connected to tap on an (E) distribution board.    'Expedited plan check per applicant request'>>	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43974	16041-10000-39577	4410 S BUDLONG AVE	90037	9	111B197   141	5017017026	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.00325	-118.29574	Installation of a new fire alarm for an existing commercial building. Installing (4) FA panels, (163) FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43975	15041-10000-04221	9561 W SAWYER ST	90034	5	129B165   969	4309011019	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	PIN	34.04581799	-118.39741157	Permit fee is $0 due to State Senate Bill SB-1222.  Plan check for Solar roof mounted with system size: 24kW, 4 inverters and 88 modules and 4 combiner boxes. Battery system Schneider Electric Conext XW with power grid PG58-27. Negatively grounded.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43976	18041-20000-04905	717 N CYPRESS AVE	90065	1	145-5A219 385	5453020024	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.09137	-118.22353	plan check for a roof mounted PV system for a commercial building. Plan check includes 15 modules with p370 power optimizers, and Solaredge SE5000. 5KVA system	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43977	16041-10000-02274	5223 W CENTURY BLVD	90045	11	090B173    89	4128017030	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	33.94559	-118.37075	T-24, TI TO AN EXISTING RESTAURANT, SCOPE OF WORK INCLUDES NEW LED LIGHTING. NO NEW CIRCUITS. TOTAL SQ. FT. 983	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43978	12041-20000-22187	13023 W ARROYO ST	91340	7	216B161    31	2514002048	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.29134	-118.41681	Plan check for power and energy. Large warehouse. Karoun Dairies. 72692 total sqft (7648 outdoor).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43979	17041-20001-42226	10410 N BECKFORD AVE	91326	12	204B121    44	2728010002	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	34.25935	-118.55103	expeditepv1install roof mounted pv system sized 5kw interonnected with msp.  line side tap.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43980	17041-10000-14442	5670 W WILSHIRE BLVD SUITE 2300	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	Title 24 plan check.  Partial floor T.I. to existing commercial office highrise.  One new 225 amp subpanel with new lighting and recepacles.  Total area = 6,508 sq. ft.     Building permit #17016-10000-10681	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43981	14041-10000-09969	110 N GEORGE BURNS ROAD	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.07564	-118.38149	REPLACING CHILLER ONE FOR ONE; REPLACE 40HP CT WITH 60HP CT; ADDING /REPLACING 60HP PUMP MOTOR; NEW MOTORS WILL BE FITTED WITH VFD ;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43982	19041-10000-53228	9400 N OAKDALE AVE	91311	12	198B113    97	2761040801	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	06/25/2020 12:00:00 AM		Permit Finaled	10/30/2020 12:00:00 AM	ADDRESS	34.24135	-118.56674	Title 24 energy plan check. Scope work of includes new indoor lighting & receptacles for restroom TI. Total effective area: 1505 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43983	09041-30003-14659	10800 W PICO BLVD #158 & 256	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.04054	-118.4272	The plan check is only for Delta 16 and 17 modifications as shown on the plan which is the addition of  3 smoke exhaust fans to the emergency system.  TI IN EXISTING SPACES # 158 & 256 (FOR EVER 21) IN WESTSIDE PAVILION.  PLAN CHECK IS FOR ELECTRICAL & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43984	13041-20000-23793	6611 N FAIR AVE	91606	2	180B173   457	2319012006	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.19073	-118.37482	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3 KW USING 13 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43985	14041-20001-20278	8751 N WHITE OAK AVE	91325	12	195B129   338	2768012037	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM			PC Approved	08/07/2014 12:00:00 AM	ADDRESS	34.23016	-118.52026	Expedited plan check fee.  System redesign.  Downsized to 40 Originally plan checked under 14041-20000-19233 (zoning clearance obtained).  Decrease in number of modules and in AC power rating of (2) inverters.  Original work description: PV1.  Install roof-mounted solar array on SFD. System size: 12kW(2) SolarEdge #SE6000A-US-ZB-U transformerless inverters(66) SolarEdge P300 power optimizers(66) Trina Solar #TSM-255PA05.18 pv modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43986	18041-10006-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.26056	-118.35206	"DELTA ""1"" CHANGES TO APPROVED PLANS TO SHOW ACTUAL FIELD CONDITIONS FOR THE LOCATION OF PULL BOXES AND CONDUITS BETWEEN THE BUILDINGS WITH MINIUM OF 24"" DEPTH AND EXTRA TRIP FOR INSPECTION.<<<SYSTEM SIZE 11.0KWAC/ 16.8KWDC (OPTIMIZERS)SCOPE INCLUDES 42 MODULES WITH OPTIMIZERS AND 2 CENTRAL INVERTERS. EXSITING SERVICE AT 600A  120/240 >>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43987	19041-30000-42209	6430 W SUNSET BLVD 1433	90028	13	147A187   154	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.09782	-118.32979	Energy PC only For a TI, Scope of work includes new lighting and receptacles.  Total sq. ft. 1300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43988	17041-10000-38024	14060 W GARBER ST	91331	6	198B153   274	2642010001	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.24172	-118.43926	plan check for roof mounted PV on single family. system size is 5.0KWac/8.96KWdc(optimizers)scope includes 28 modules with optimizers and a single inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
43989	19041-10000-01913	4130 N CAHUENGA BLVD	91602	4	165B177  1002	2424040008	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.14515	-118.36125	PLAN CHECK FOR TITLE 24 ONLY FOR - IN/EXTERIOR WITH A TOTAL AFFECTED AREA = 1350 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43990	17041-10000-14105	19748 W DEARBORN ST	91311	12	198B117   185	2761001054	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.23711	-118.56389	Plan check for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new led ones.Area: 21,500 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43991	15041-10000-03073	312 E 1ST ST 4TH FLR	90012	14	130-5A213 169	5161017035	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.0501	-118.24075	PC FOR ENERGY ONLY. TI IN A 5 STORY BUILDING, FOURTH FLOOR.CHANGE OF USAGE FROM IRS OFFICE TO INTERNET OFFICE. TOTAL AREA 4474 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43992	11041-20000-19055	9590 W HIDDEN VALLEY ROAD	90210	4	156B165   229	4387007001	RE20-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2011 12:00:00 AM			Corrections Issued	10/21/2011 12:00:00 AM	ADDRESS	34.12115	-118.40524	PLAN CHECK FOR NEW 2-STORY 2-CAR GARAGE AND ACESSORY LIVING QUARTER WITH 600A SERVICE SUPPLYING MAIN DWELLING AND ACCESORY LIVING QTR (2 OF 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
43993	16041-20001-29419	12117 W VALLEYHEART DR	91604	2	165B165  1095	2367014040	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Apartment			08/10/2018 12:00:00 AM			PC Approved	08/24/2018 12:00:00 AM	ADDRESS	34.14595	-118.39679	08-10-2018 Changes to an approved set of plans, Changes include equipment layout in electrical reconfigured, update layout to as built. Remove Stand by Generator(Variance has been obtained for Horizontal Exit by Building department). Plan check only, permited covered on the master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43994	19041-10000-28604	12925 N BRADLEY AVE	91342	7	222B145   472	2506003017	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.30432	-118.45895	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
43995	11041-20000-17180	4211 N EAGLE ROCK BLVD	90065	14	156A219   107	5473024024	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM			PC Approved	08/15/2011 12:00:00 AM	ADDRESS	34.12229	-118.22486	PLAN CHECK T24 ENERGY FOR NEW BAKERY AREA WITHIN EXISTING MARKET SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43996	17041-20000-04253	1697 S PACIFIC AVE ROOFTOP-BAR	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	33.98722	-118.47211	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NEW ROOFTOP BAR. PHASE 2. NOT A HIGHRISE PER APPLICANT. NEWLY CONNECTED LOAD < 400 AMPS.  320 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43997	15041-20002-28031	1638 E VERNON AVE	90011	9	112-5A213  86	5106003025	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.00372	-118.24454	12/17/2015 Plan check for a lost set of PV plans. System has remained the same. Permit to be pulled under master application.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. Systems size is 5 kWac and consists of (1) inverter, (24) modules, and (24) power optimizers. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
43998	19041-20000-42373	1210 N CHANTILLY ROAD	90077	5	147B149   574	4369037012	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.09496	-118.45667	PV1.  Install 5.84 kW DC/5.31 KW AC CEC roof mounted grid tied PV system addition to existing pv along with a new 27 kWh energy storage system. scope of work consists of (16) pv modules with microinverters, (2) sub panels, and (2) batteries	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
43999	16041-10001-27747	1124 S SAN JULIAN ST	90015	14	124-5A211 188	5145025002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.03521	-118.25351	PC FOR POWER SYSTEM. ADDITIONAL SCOPE OF WORK TO INCLUDE AC PANEL AND ADDITIONAL LOADS. PC FOR POWER SYSTEM DUE TO PLACE OF ASSEMBLY. PERMIT ISSUED FOR SOME CIRCUITS ALREADY. THIS PERMIT SHALL COVER PLAN CHECK TIME AND PERMIT FOR ADDITIONAL ITEMS. All WORK TO BE DONE UNDER DELTA 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44000	13041-10000-34127	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	33.95466	-118.38556	replacement of 10 existing fuel dispensers.Using existing branch circuits. Permit obtained on 13041-90000-22776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44001	15041-20000-43285	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Info Complete	12/22/2015 12:00:00 AM	ADDRESS	33.79072	-118.29449	PLANCHECK FOR POWER ONLY.  REPLACE (E) 500KW GENERATOR AND TWO AUTOMATIC TRANSFER SWITCHES IN KAISER PERMANENTE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44002	19041-20000-47556	755 N STRADELLA ROAD	90077	5	141B149   145	4369022003	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.08265	-118.45298	600A 240/120V 1ph-3w service, distribution, power, and lighting for addition to (E) building.  Plan check for power.Permit issued for 600A service upgrade.  Electrical permit for building wiring issued separately under 17014-30000-02451 building combination permit.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44003	17041-20001-31627	2322 S DUXBURY CIR	90034	5	126B165   488	4309014015	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.04189	-118.39598	Expedited plan check fee. PV1.  Install 13.37 kW AC CEC roof mounted grid tied PV system.  (56) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44004	15041-10000-14523	416 S WESTLAKE AVE	90057	1	133-5A205 196	5154026015	R4-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			05/12/2015 12:00:00 AM			Verifications in Progress	07/24/2015 12:00:00 AM	ADDRESS	34.06015	-118.27263	SERVICE UPGRADE TO 800 AMP TO AN (E) BUILDING, ALL SUB PANELS TO REMAIN, METHANE ZONE . PC FOR POWER ONLY. SUBMITTED PER  M.Z .PERMIT TO BE CLOSED - PC UNDER SEPARATE PERMIT WILL BE CONDUCTED FOR 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44005	18041-10001-04175	1754 N TAFT AVE	90028	13	150A191   378	5586034011	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			No Progress	01/10/2019 12:00:00 AM	ADDRESS	34.10333	-118.31458	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. ADDING FEW STROBS AND REMOVING FEW SMOKE DETECTORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44006	18041-10000-07825	4955 N VAN NUYS BLVD #611	91403	4	169-5A151  13	2263026046	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.16078	-118.4489	Plan check for power and energy for existing Medical office building. Total area: 556 sq ft.B#18016-10000-06569	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44007	10041-20000-12086	5601 W CENTURY BLVD	90045	11	090B173    55	4125026007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	ADDRESS	33.94571	-118.37928	new parking lot lightingEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44008	16041-10000-41068	13047 W KELOWNA ST	91331	7	204B161   651	2623019014	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.25305	-118.41673	PC FOR PV SYSTEM TOTAL OF 7.6 KW AC USING CENTRAL INVERTER SYSTEM WITH 30 MODUES IN TOTAL. ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44009	15041-10000-34879	9705 W MUSTANG WAY	91040	7	204B181    73	2549025035	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.25888	-118.34346	PV1, ROOF MOUNTED SOLAR SYSTEM TOTAL SIZE 4.56KW-DC. (16) MODULES AND (16)MICROINVERTERS. (16) SW285 MONO(16)ENPHASE M250-60-2LL-S2X	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44010	19041-20001-12410	6201 W HOLLYWOOD BLVD	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM			PC Approved	09/05/2019 12:00:00 AM	ADDRESS	34.1018	-118.32461	Revisions to approved set of plans and expansion of permit scope.  Extensive power and lighting additions.  Changes to SLD limited to load calculations.  Delta-1, 2, and 3 revisions.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44011	14041-10000-15857	119 E PICO BLVD	90015	14	124-5A209  76	5139027013	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.03603	-118.25961	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 4175 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44012	16041-20000-26826	12975 W JEFFERSON BLVD	90066	11	102B157    93	4211008026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	33.97533	-118.42387	New 210kW fuel cell system for Home Depot. Interconnected with (E) 480/277 3ph 4W service. Fuel Cell is utility interactive.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44013	17041-20000-27607	6100 W CENTER DR Suite 1130	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	33.97733	-118.3922	Plan check for energy only. TI to existing office suite 1130 in high rise building. 4,829sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44014	15041-20000-00131	20350 W VENTURA BLVD Suite 205	91364	3	171B113    28	2166035030	(Q)CR-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			01/05/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.16881	-118.57601	TI to an existing 2 story office building. Adding new lighting and new controls to SUITE 205. Using existing pannels. Plan check for energy. 2298 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44015	19041-20000-16337	10120 N HAYVENHURST AVE	91343	12	204B137   663	2678024004	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.25458	-118.49345	Install 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44016	17041-20000-00220	4338 N TUJUNGA AVE	91604	2	165B173   511	2366005006	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.14887	-118.37881	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 1,812 sq. ft.Note: Building application has been generated under 16016-10000-24506	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44017	19041-10001-51513	11860 W WEIR ST	90230	11	108B161   772	4218018012	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			PC Approved	01/09/2020 12:00:00 AM	ADDRESS	33.99	-118.40755	(off -hours fees)plan check for PV-1, system size is 7.19KW, solar tile system. (2) inverters, first (5.2KW) and the second (3.8KW). 2 energy storage systems.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44018	13041-10000-12259	851 S GRAND AVE	90017	14	127-5A209  54	5144020012	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.04476	-118.25923	New service and distribution network for air conditioning in a high-rise hotel originating in basement station.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44019	18041-10000-28261	1400 W 240TH ST STE B	90710	15	042B193   785	7439012007	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.80683	-118.30128	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44020	11041-20000-18853	10600 N WHEATLAND AVE	91040	2	207B177   136	2528031001	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.26266	-118.35832	single family solar 7.5 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44021	17041-20000-14453	11262 W OTSEGO ST	91601	2	171B173   919	2353013009	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			05/02/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.16279	-118.37674	new fire alarm system 153 devices and facp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44022	13041-10001-12772	18555 W DEVONSHIRE ST	91326	12	204B125    99	2728028016	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	PIN	34.25817975	-118.53780185	REVISIONS TO PERMITTED SET OF PLANS-PLAN CHK ONLYREMODEL OF EXISTING ALBERTSONS MARKET FOR SMART AND FINAL STORE, DEMO AND REPLACE STORE LAYOUT.  EXISTING ELECTRICAL SERVICE AND MAIN SWITCHBOARD.  NEW SUBFED DISTRIBUTION BOARD (800A BUSSING).  RELOCATED TENANT PANELS.  NEW LIGHTING, POWER TO REFRIGERATED HVAC EQUIPMENT.  UNDERGROUND CHECKSTAND POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44023	17041-20000-12609	22257 W YBARRA ROAD	91364	3	168B101   840	2170004008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.15396	-118.61168	PV1.  Install 5.12 kW roof mounted grid tied PV system.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44024	11041-10000-23639	2839 N HYPERION AVE	90027	4	151-5A205 135	5433027030	C4-1D	Central	Hollywood	Greater Griffith Park		1952.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	01/11/2012 12:00:00 AM	ADDRESS	34.10919	-118.27202	title 24 and emergency lighthing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44025	19041-10000-40484	3651 S WATT WAY 6TH FLOOR	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.02013	-118.28812	PLAN CHECK ENERGY ONLY FOR T.I. TO LAB FOR CASEWORK ON THE 6TH FLOOR.  INSTALLATION OF NEW LIGHTS.  T-24 ENERGY OPNLY. APPROX. (1170) SF OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44026	13041-10000-28872	3901 N EAGLE ROCK BLVD BLDGF	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.11925	-118.23127	"INSTALLING FIRE ALARM SYSTEM,   APARTMENT BUILDING ""F"" (6 OF 7 buildings)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44027	13041-10000-23257	6600 N TOPANGA CANYON BLVD SPACE 93	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	TITLE 24 PLAN CHECK ONLY. MALL . 2 FLOORS. WORK ON SPACE #93. EMERGENCY LIGHTING. 2187 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44028	18041-10000-37886	411 S NORMANDIE AVE	90020	10	135B193   460	5502016015	R4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.03	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	11/14/2020 12:00:00 AM	ADDRESS	34.06672	-118.30068	PLAN CHECK FOR FIRE ALARM SYSTEM INCLUDING 1 FIRE ALARM PANEL WITH 880 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44029	17041-10000-06461	1999 S AVENUE OF THE STARS #2500	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	T-24, PC FOR ENERGY ONLY. TI TO (E) OFFICE SPACE ON THE 25TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3105 SQ. FT. B#17016-10000-01289	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44030	15041-10000-38928	5330 N LOLETA AVE	90041	14	163-5A227  24	5691001012	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	07/02/2016 12:00:00 AM	ADDRESS	34.14427	-118.198	PV1, ROOF MOUNTED SYSTEM. INSTALLING (25) MODULES AND (2) 4.2 INVERTERS. TOTAL SIZE 8.4KW-AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44031	16041-10000-22138	1110 N BATES AVE	90029	13	145-5A201  40	5429008017	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.09483	-118.28235	PC for T-24 only, remove HID fixtures and replace with new LED fixtures. Total area: 4,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44032	18041-20000-21154	2030 E SACRAMENTO ST	90021	14	123A217   252	5166010024	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.03042	-118.23108	Change of use from (E) warehouse to (N) office.  Plan check for energy - 9600 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44033	15041-10001-42333	2148 E BAY ST	90021	14	123A217   191	5166005010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM	ADDRESS	34.0314	-118.22816	03/02/16Changes to an approved set of plans. All changes are made under delta 1. Adding/replacing lighting fixtures and receptacles.   NOTE: PULLED PULLED UNDER PCIS#15041-10000-42333(((((T-24, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING FOR INDOOR AND OUTDOOR SPACES  AND NEW RECEPTACLES. TOTAL SQ. FT. 9877.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44034	13041-20001-07316	11121 W PENDLETON ST	91352	6	198B173    45	2538011010	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.23852	-118.37336	(((PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 2. INCLUDES NEW FEEDERS AND NEW LOADS))))PLAN CHECK POWER AND ENERGY FOR NEW METAL BUILDING RECYCLING MATERIAL SORTING FACILITY AND TRANSFER STATION. 4000A SERVICE. SITE LOCATED IN METHANE BUFFER ZONE LEVEL II. NO METHANE MITIGATION REQUIRED PER REPORT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44035	16041-20001-27201	9301 N TAMPA AVE FC2	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM			PC Approved	04/19/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Changes to an approved set of plans.  Changes include to different light fixtures and revised energy calculations.  This ia plan check only.TI TO AN EXISTING COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  NO NEW LOADS REARRANGEMENT OF EXISTING CIRCUITS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 880.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44036	14041-10000-20788	11101 S HINDRY AVE	90045	11	087B173    57	4129037010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.93388	-118.37248	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44037	13041-10000-30568	600 W 7TH ST STE 160	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.04728	-118.25685	"TITLE 24, PART 6 FOR ""JIMMY JOHN'S"" IN EXISTING RESTAURANT SPACE. TENANT IMPROVEMENT IS FOR LIGHTING IN 1515 SQ FT AREA. WORK IS DONE ON THE FIRST FLOOR OF A HIGH-RISE BUILDING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44038	11041-10000-06492	17380 W SUNSET BLVD	90272	11	126B117   650	4415019012	C2-1VL, C2-1XL, P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			PC Info Complete	04/19/2011 12:00:00 AM	ADDRESS	34.03924	-118.55462	Install planter J-boxes as shown on the site plan.  Includes conduit and wiring from panel NC and control circuit thru EMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44039	16041-20000-37726	2938 N ALLESANDRO ST	90039	13	150B213   787	5442024026	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.10496	-118.24522	remove existing hid fixtures and replace with new led outdoors.  plan check for energy 10940 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44040	18041-10000-43122	11916 W PICO BLVD	90064	11	123B149   970	4259039054	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Apartment			11/09/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	12/24/2020 12:00:00 AM	ADDRESS	34.02999	-118.44856	Plan check for a PV1 23.4KW AC / 28.3 KW DC roofmounted system with (2) inverter, (82) modules, and (41) optimizer interconnecting through a new load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44041	17041-10000-31780	10643 W SUNSET BLVD	90077	5	138B153   103	4362009012	A1-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.07571	-118.44485	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FIXURES FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44042	19041-10001-00976	1236 N STRADELLA ROAD	90077	5	147B149   572	4370007016	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.09482	-118.45495	expedited feesPV1, NEW ROOF MOUNTED SOLAR SYSTEM TO A SINGLE FAMILY DWELLING USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (1)10KWAC INVERTER, (37) MODULES AND (37) OPTIMIZERS. TOTAL SYSTEM SIZE 13.32 KWDC/ 10KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44043	10041-20002-12643	13550 W PAXTON ST	91331	7	210B157   162	2535002014		North Valley				1043.20	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.27276	-118.42714	Plan check for revision to approved plans Delta 9 changes.  Relocate AC point of connection. Include permit for branch ckt for convenience outlet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44044	13041-10002-11284	710 N EL CENTRO AVE	90038	13	141B189   274	5534035018	(T)(Q)RAS3-1	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Apartment			03/27/2015 12:00:00 AM			PC Approved	04/27/2015 12:00:00 AM	ADDRESS	34.08386	-118.3243	TI TO AN EXISTING BUILDING.  CONVERTING THE LOBBY/EXERCISE ROOMS ON THE FIRST FLOOR TO COFERENCE ROOM/THEATER/EXERCISE ROOMS. ADDING NEW LIGHTING TO THE ROOF. NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.TOTAL SQUARE FOOTAGE 6817.pc for power and energy. ~28 typical units. methane buffer zoneNew privately funded 84 unit mixed use project.4 Stories Type VA fully sprinklered R2 occupancy with M Occupancy commercial over 2 levels Type I S2 Occupancy basement parking. Project utilizes housing incentives per Sec. 12.22.25 of the Zoning Code providing 4 Very Low Income units using Parking Option No. 1 (139 residential, 26 commercial parking spaces)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44045	18041-20000-23221	5077 N HOOD DR	91364	3	171B113   495	2175020012	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.1618	-118.56758	Plan check for addition PV  and battery back up system to existing PV system, additional PV system size: 7.6kWac with 30 modules and 1 inverter(7.6kW) and 9.8kW LG CHEM	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44046	12041-20000-22159	15024 W MAGNOLIA BLVD	91403	4	171A147    24	2263004013	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/18/2012 12:00:00 AM			PC Approved	09/18/2012 12:00:00 AM	ADDRESS	34.16458	-118.46045	5-unit apartment building with less than 400A of load.  Plan Check Only for T-24 in the common areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44047	18041-20002-32909	10146 W BAYWOOD CT	90077	5	153B153    54	4382029***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM			PC Approved	12/05/2018 12:00:00 AM	ADDRESS	34.11783	-118.44128	Relocation of equipment.$0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.(((Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6.65 kWdc/7.6 kWac and consists of (1) inverter, (19) modules, (1) load center, (1) auto-transformer, and (1) LG Chem battery.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44048	12041-20000-13826	8011 S OSAGE AVE	90045	11	099B173   597	4105029012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2012 12:00:00 AM			Reviewed by Supervisor	07/06/2012 12:00:00 AM	ADDRESS	33.96525	-118.37886	New root mounted P.V. system with Enphase microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44049	18041-20000-40875	4446 N TOBIAS AVE	91403	4	168A151   281	2265006006	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.15287	-118.45185	PV1.  Install PV roof mounted system, system size: 15.48KW DC, 13.76KW AC with 43 AC Modules connected to Sub-panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44050	14041-20000-12127	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	ADDRESS	34.06237	-118.35809	PLAN CHECK FOR T-24 AND EMERGENCY LIGHTING ONLY ON AN EXISTING COMMERCIAL HIGH RISE BUILDING 31ST FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44051	15041-10000-35079	714 N SWEETZER AVE	90069	5	141B173   374	5528003040	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/22/2021 12:00:00 AM	ADDRESS	34.08415	-118.37017	FULL PC, NEW 5-STORY APARTMENT WITH 26 UNITS W/ ROOF DECK ON 2-STORY SUBTERRANEAN PARKING PODIUM STRUCTURE. 3 TYPICAL UNITS 2500 AMP SERVICE  TOTAL SQ. FT. 61,639 S.F.).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44052	18041-10001-23042	1051 N SWARTHMORE AVE #1-104	90272	11	129B125   836	4423016021	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.04828	-118.52508	"Change to approved set by changing the feeder and conduit size. All changes under delta-2 only.(((PLAN CHECK FOR POWER AND ENERGY FOR - First time tenant improvement to existing retail space #1-104 ""Paige Jean"" within Palisades Village Shoping Center. TOTAL AFFECTRED AREEA = 1261 SF.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44053	18041-10000-09798	6255 W SUNSET BLVD #1030	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR T24 ONLY,  TENANT IMPROVMENT TO THE (E) OFFICE SPACE . INSTALL NEW LIGHTINGS AND POWER, NEW CIRCUIT CONNECTS TO EXISTING PANEL IN THE SPACE. TOTAL AREA: 3,292 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44054	17041-20001-13768	4126 W JEFFERSON BLVD	90016	10	120B181   764	5046006001	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.02541	-118.34141	12.11.2017 - Plan check for energy only. TI to existing commercial space. New lighting (incl. emergency) - 3,441sqft. Partial permit fees collected under parent application #17041-30000-13768. Supplemental permit will be issued.======INSTALL 11 NEW LED SHOP LIGHTS, UP GRADE EXISTING OUTLETS AND SWITCHES AS PER CITY CODE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44055	16041-10000-41488	757 S ALAMEDA ST BLDG 3	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.0318	-118.23916	PC FOR POWER AND ENERGY.SCOPE INCLUDES NEW SERVICE, NEW EQUIPMENT AND NEW LOAD  ***  4.8 KV  ***  MEDIUM VOLTAGETOTAL AFFECTED AREA OF 326083 SQ. FT INDOOR  and 15272 FOR OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44056	09041-10007-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Review the Master 34.5kv single line plans and those for distribution boards (serving the North Concourse and the South Concourse of the TBIT).showing the trip settings of the overcurrent devices. Short circuit study bearing the stamp and signature of the engineer on record shall accompany these plans to verify  that changes to AIC ratings of the electrical equipment are as required by the electrical code.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44057	15041-20000-40306	16314 W STARE ST	91343	12	204B137   884	2678008015	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.25285	-118.48771	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (20) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44058	17041-10003-37289	8619 S HAAS AVE	90047	8	097-5A191 317	6036001044	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	33.95936	-118.31736	03-21-2018 Changes to permtted set of plan Changes include replace old PV inverter with new PV inverter size, from PVI-3.0-OUTD-S-US to PVI-3.6-OUTD-S-US at same location. Plan check only. Changes apply to clouded area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44059	14041-20000-05682	1445 S FAIRFAX AVE	90035	10	129B173   668	5068017024	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			03/03/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	PIN	34.05018628	-118.36718085	T24 FOR NEW APARTMENT BUILDING. TOTAL CONNECTED LOAD DOES NOT EXCEED 400A. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44060	18041-20000-11061	4310 E MERCURY AVE	90032	14	142-5A229 151	5305027027	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Issued	04/04/2018 12:00:00 AM	ADDRESS	34.08548	-118.19403	Plan check for a PV1 ground-mounted PV system. System size is 5 kWac and consists of (1) inverter and (17) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44061	13041-10000-07819	1529 E PLEASANT AVE 1-3	90033	14	129A221    57	5174021035	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Apartment			03/27/2013 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.04894	-118.2212	T24 FOR NEW 3 STORY APARTMENT BUILDING TOTAL CONNECTED LOAD LESS THAN 400A. INDOOR AND OUTDOOR LIGHTING. TOTAL SQRFT FOR OUTDOOR: 3995 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44062	16041-20000-14035	3141 W SAN FERNANDO ROAD	90065	13	154-5A213 198	5458007009	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.11596	-118.24673	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/water damage repair. Total lighting area = 1,256 sq. ft.Note: Building permit has been pulled under 15016-20000-23975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44063	10041-20000-05986	14500 W ROSCOE BLVD #203	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.22136	-118.44937	office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44064	15041-20000-02590	202 W 1ST ST 6-4010	90012	14	130-5A213  10	5149001006	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.05285	-118.24474	Plan check for energy only. TI to existing offices in office building. New lighting and receptacles. 468sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44065	15041-30001-42248	19418 W LEMARSH ST	91324	12	204B117   315	2726017012	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.25537	-118.55695	Expedite fees only.    Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 12 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44066	15041-10000-16741	7331 S RINDGE AVE	90293	11	093B149    24	4116028007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM			Reviewed by Supervisor	06/08/2015 12:00:00 AM	ADDRESS	33.95426	-118.44609	PV 1 ROOF MOUNTED SYSTE. 36 MODULES AND 1 INVERTER. TOTAL SIZE. 9.36. (36) KYOCERA #KU2606XPA (1) FRONIUS # IG PLUS A 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44067	16041-10000-10168	3217 S CENTRAL AVE	90011	9	117A209   244	5114019013	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			Verifications in Progress	04/25/2016 12:00:00 AM	ADDRESS	34.0143	-118.25668	"(TI) to an (E) commercial build. ""Basket Room"".  Install new lights and receptacles. PC for T-24 only, total area: 3,400 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44068	16041-20001-40157	9251 N WOODLEY AVE	91343	12	198B141   487	2676014025	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.23899	-118.48523	Expedited per applicant request.Plan check for the addition of a PV system onto an existing PV1 roof-mounted PV system. System addition size is 3 kWac for a total system size of 9 kWac. System addition consists of (1) inverter, (12) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44069	16041-20000-04517	905 S LE DOUX ROAD	90035	5	132B173   177	4333022013	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			08/02/2016 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.06069	-118.37752	Plan check for New 5 story 21 units appartment building. Service size: 1,600A Total area: 16,503 sq ft.Note: Building permit has been issued under 15010-30000-00015	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44070	11041-20000-00305	11850 W SHELDON ST	91352	6	198B169    65	2538002040	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			PC Info Complete	01/07/2011 12:00:00 AM	ADDRESS	34.24066	-118.39159	Install general/emegency lighting in new additional warehouse.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44071	19041-10000-38378	524 W 113TH ST	90044	8	087A201   204	6075026009	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.93179	-118.28361	PC FOR PV-1 SYSTEM. SYTEM SIZE IS 3.80.  12 MODULES WITH 1 SMA  AMERICA (SB3.8-1SP-US-40) INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44072	12041-10000-01092	5955 N DE SOTO AVE # 100	91367	3	177B105    78	2149002027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02, 1371.02	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.17888	-118.59071	TI in an existing office. EPC is for T24.  Circuit count for permit was indicated by contractor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44073	15041-10001-38972	701 E 3RD ST 3rd fl	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Expired	04/09/2018 12:00:00 AM	PIN	34.04581508	-118.23784015	"Changes on approved set, marked as ""Field Revision Delta-1 and Delta-2"":Adding branch circuits and motor loads. Load changes on single line diagram and panel load schedule; However, it's still less than 400A.No changes on T-24 [Master plan was checked for T-24 only] <<TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 13030>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44074	16041-10000-44778	600 W 78TH ST	90044	8	099B201   438	6020016005	RD2-1	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	33.96871	-118.28417	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.84KWac.(12)MODULES-SUNPOWER X21-335-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44075	14041-20000-14917	3612 W 6TH ST	90005	10	135B193   873	5502032005	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	PIN	34.0633338	-118.3007217	Change of use from retail to bar on first floor in 4-story hotel.  Occupant load is 142 occupants per building permit.  Install new 400A section to feed  tenant subpanels, branch circuits, and lighting.  The 400A bus is braced for 65K AIC, and down stream circuit breakers are series rated at 65KA.  Plan check power and energy.Note: New service upgrade is under 14041-10000-26289.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44076	18041-10000-40840	9601 S COAST GUARD ROAD	90045	11	090B157   100	4117032900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.9458	-118.42112	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44077	18041-10001-40458	13700 W SHERMAN WAY	91405	2	183B157   986	2216027022	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Issued	10/16/2019 12:00:00 AM	ADDRESS	34.20093	-118.43163	Changes to an approved set of plans. All changes are clouded under delta B. Changes include revising lighting/power plans to reflect as built, revising title 24 calculations, and revising emergency photometrics.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44078	19041-20000-08811	13963 W POLK ST	91342	7	228B153   537	2504009014	RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.31798	-118.4383	PV1.  Install 14.625 kW DC / 11.4 kW AC roof mounted grid tied PV system.  (45) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44079	13041-20000-23743	5720 N FULCHER AVE	91601	2	174B173   546	2337028006	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.1745	-118.3729	pv1 single family dwelling total system seize 4.2 kw ac using 20 modules transformerless inverter nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44080	12041-20000-03212	18520 W WYANDOTTE ST	91335	3	186B125   882	2118029002	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM			PC Approved	02/10/2012 12:00:00 AM	ADDRESS	34.20283	-118.53686	WAREHOUSE T.I.ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44081	16041-10000-30475	4000 S LA BREA AVE	90008	10	117B177   657	5028004902	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.01465	-118.35525	Plan check for Title 24 indoor and outdoor lighting, remove HID fixtures and replace with new LED fixtures. Total area: 50,660 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44082	13041-20000-19358	5412 W WILSHIRE BLVD	90036	4	132B181    15	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.06208	-118.34672	FIRST TIME OCCUPANCY. PC FOR T24 ENERGY AND POWER. NEW LIGHTING. TOTAL AREA 2320 SQ FT. NEW SALON. UNIT EQUIPMENT ALLOWED PER SPECIAL PERMISSION. IF CHANGE OF OCCUPANCY OR HIGH OCCUPANCY OCCURS, A GENERATOR WITH 4 HOUR FUEL SUPPLY TO BE REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44083	14041-10001-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			11/16/2016 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	33.95713	-118.3847	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGES FROM COPPER FEEDERS TO ALUMINUM FEEDERS. CHECKING FOR NEW SIZING AND AIC RATINGS. PC ONLY, PERMIT ALREADY ISSUED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44084	14041-10000-10559	11723 W BARRINGTON CT	90049	11	135B145   628	4401007008	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.06437	-118.46984	Plan check for power & energy for 2-stories commercial building.  New 800 amp service and relocating pannels and loads.Area = 3000 sq feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44085	13041-20000-24584	2345 N ACHILLES DR	90046	4	153B173   811	5569007055	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.11331	-118.36699	New rooftop PV System with 4 strings.  Submitted per applicant request.  Plan Check/Permit is for PV System only, NOT for Service Upgrade or de-rating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44086	18041-20001-07331	5021 N MONTEZUMA ST	90042	1	151-5A225  85	5469009039	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.11089	-118.20564	06-14-2018 Changes to an approved set of plan. Changes include change conductor size from #1 to #2 between Main Panel and sub-panel. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44087	19041-10000-08729	6509 W DE LONGPRE AVE Panel HP	90028	13	147A187   250	5546014016	C2-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.09625	-118.33056	PV2. NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL COMPLEX. SYSTEM CONSIST OF A CENTRAL INVERTER (SE7600H-US), 22 MODULES (SUNPOWER SPR-E20-435) AND POWER OPTIMIZER (SE P505). SYSTEM SIZE IS 9.57KWdc AND 7.6KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44088	12041-10000-29428	633 W 5TH ST SUITE 3320	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM			Corrections Issued	12/13/2012 12:00:00 AM	ADDRESS	34.05099	-118.25468	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN A HIGH RISE BUILDING. LOCATED ON FLOOR 33 SUITE 3320.  950 SQUARE FEET IN CONFERENCE ROOMS AND OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44089	10041-20000-11790	333 S HOPE ST 48th Floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check T-24 Energy (general/emergency) lighting on office spaces on the 48th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44090	12041-10000-23527	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK POWER. NEW 600A BOARD SUPPLYING POWER CENTER FOR TBIT SIGN LIGHTING AND FUTURE LOADS.  PLAN IS NOT CHECKED FOR ENERGY. PER APPLICANT, PLAN CHECK FOR T-24 ENERGY IS ON #12041-10000-23512	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44091	18041-10002-41028	119 N HOBART BLVD	90004	10	138B193   841	5517011033	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.07435	-118.30564	<<<Expedite Fees>>> DELTA CHANGES TO APPROVED PLANS FOR CHANGING THE NUMBER OF PV PANEL FROM 30 TO 31 AND CHANGING THE SIZE OF THE PANELS FROM 300W TO 335W EACH. TOTAL PV SYSTEM IS RATED AT 10.385KW.   NO FEE PER AB1414.<<<Install New Rooftop PV system, 7.2 kW AC / 9kW DC. Install (30) modules and (30) IQ7 enphase micro inverter.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44092	17041-20000-31609	2934 N BEVERLY GLEN CIR Unit A	90077	5	156B153    17	4382030065	RE15-1VLD-RPD-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.12765	-118.44349	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 635 sq. ft.Note: Building permit has been issued under 17016-30000-17788	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44093	15041-20000-16023	11846 N SHOSHONE AVE	91344	12	216B129   331	2601041057	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.28637	-118.51615	0$ permit fees due to senate bill 1222.Installation of roof mounted solar PV array.  Total system size = 15.2 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44094	13041-10000-03456	520 S VIRGIL AVE #502	90020	4	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.06457	-118.28687	REMODELING OF MEDICAL OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44095	14041-10000-01235	523 W 6TH ST 6TH FLR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT ON 6TH FLOOR ( OFFICES). 5395 SQFT, EMERGENCY CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44096	13041-10000-31360	1810 S BROADWAY	90015	14	123A207    63	5126029009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Expired	12/08/2015 12:00:00 AM	ADDRESS	34.03232	-118.26486	"NEW FIRE SPRINKLER ALARM SYSTEM IN 2-STORY RETAIL BUILDING (""ASHLEY FURNITURE""). TOTAL OF 50 DEVICES, 2 PANELS. TOTAL AREA TO BE 41,627 SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44097	12041-10000-01152	2038 E BAY ST	90021	14	123A217   194	5166011014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM			PC Approved	01/18/2012 12:00:00 AM	ADDRESS	34.0313	-118.23081	Plan check T24 Energy/Emergency lighting for 2 story live/work building common areas only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44098	11041-20000-08610	19389 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.18744	-118.55559	"T.I. to existing building for Party City.  Install general/emergency lighting.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date02/13/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44099	19041-10000-53479	4317 W BEVERLY BLVD	90004	13	138B193   427	5521033018	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.20	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			Quality Review Completed	01/10/2020 12:00:00 AM	ADDRESS	34.07641	-118.3029	Scope of work includes new power equipment connected to 2500A bus. Adding new panelboards and circuits.  Core and shell museum.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44100	12041-10001-30800	15541 W ROSCOE BLVD	91343	6	192B145   364	2654028009	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.22156	-118.47147	MODIFICATION TO APPROVED SET OF PLANS. CHANGES MADE TO OUTDOOR LIGHTING UNDERNEATH THE CANOPY. CHANGES CLOUDED DELTA 2.***************************************************************PV2 SOLAR INSTALLTION ROOF MOUNT AND CAR PORT SINGLE STORY BUILDING[INVERTER TYPE: POWER ONE PVI-10.0-I-OUTD-S2-US-480][MODULE: REC250PE BLK] 16 STRINGS, 187 MODULES SYSTEM SIZE 46.75 KWDCADDRESS CHANGE TO 15505 PER APPLICANT REQUEST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44101	12041-10000-11476	325 W ADAMS BLVD	90007	9	121-5A205 132	5126018032	(T)(Q)C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Public Safety Only			05/21/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.02712	-118.27319	New Fire alarm system for 915 units residential Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44102	13041-20000-33265	10100 W GALAXY WAY	90067	5	132B161   690	4329008261	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.05582	-118.41064	Change to lighting in an existing exercise gym.  All circuits are existing, no new loads per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44103	15041-20001-21844	8246 N SHOUP AVE	91304	3	192B101   655	2012023009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM			PC Approved	07/20/2015 12:00:00 AM	ADDRESS	34.21927	-118.61452	Expedited per customer request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (36) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44104	13041-10000-22533	11974 N BEAUFAIT AVE	91326	12	216B125    77	2870023044	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.29038	-118.53583	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN (NEGATIVELY GROUNDED). SYSTEM SIZE IS 10.78 KW DC AND 10.0 KW AC. [MODULES: TIRNA SOLAR # TSM-245PC05 |||| INVERTER: FRONIUS # IG PLUS V 10.0]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44105	18041-20001-47500	341 N WEST CHANNEL ROAD	90402	11	123B129   800	4410022006	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.0306	-118.51439	Expedit per applicat requestPlan check for PV roof mounted with energy storage system, PV system size: 7.56kW DC, 6.7kW AC with 21 AC Modules, SONNEN BATTERY SYSTEM ECO 16. connected to  existing 400A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44106	15041-20000-21953	6220 N TOPANGA CANYON BLVD K-9060	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	Plan check for power and energy. Project scope is a first time tenant for a kiosk at the Westfield Village project. Total ligthting area = 265 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44107	15041-20000-01389	1045 W 46TH ST	90037	9	111B197   371	5017031013	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	34.00176	-118.29327	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.25 KW. (29) HYUNDAI HISM250(29) ENPHASE ENERGY M215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44108	16041-20000-43961	22502 W SOUTH SUMMIT RIDGE CIR	91311	12	198B101   250	2727022024	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.23964	-118.61686	Plan check for installation of ground-mounted solar pv system for SFD. Interconnect with 400A MSP.18kW (6+6+6) ungrounded system. (70) 345W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44109	19041-10001-03775	1623 S CREST DR	90035	5	129B169   687	4305010014	R1V2	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.05011	-118.38764	Expeited Per Customer RequestPC FOR NEW 5.2 KW ROOFTOP PV SYSTEM AND 13.5KW ENERGY STORAGE SYSTEM, SCOPE INCLUDES (1) TESLA POWER WALL BATTERIES, (16) PV MODULES, AND (1) SE5000A INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44110	15041-20000-31005	221 N FIGUEROA ST STE 400	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	TI TO 4TH FLOOR. REBUILD FIRE DAMAGED AREAS. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44111	18041-20000-21624	10201 W PICO BLVD Bldg 57	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.04994	-118.41129	Plan check for Title 24 only. Project site is the front entry of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 670 sq. ft.Note: Building permit has been issued under 17016-10000-38591	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44112	16041-20001-29020	5461 W JEFFERSON BLVD	90016	10	120B177   474	5048017040	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	09/22/2016 12:00:00 AM	ADDRESS	34.02617	-118.36558	VOID.........EXPEDITE PER APPLICANTPV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 96KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44113	18041-10000-26932	379 S LOMA DR	90017	1	133-5A207 233	5153007021	R4-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.05879	-118.26682	PLAN CHECH FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44114	11041-10000-20074	1708 S FIGUEROA ST	90015	9	124-5A205 113	5126010007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM			PC Info Complete	11/14/2011 12:00:00 AM	ADDRESS	34.03608	-118.27073	NEW FREE-STANDING 27.6 KW PHOTOVOLTAIC SYSTEM IN A PARKING AREA WITH INTEGRATED OUTDOOR LIGHTING.  4 INVERTERS WITH 120 MODULES.  PLAN CHECK IS FOR POWER (PV) AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44115	10041-10000-20911	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	12/21/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	First time tenant for a commercial building. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44116	16041-10000-45834	9278 N JUNEBERRY LANE	91343	7	198B145   458	2656021***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.23959	-118.46176	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44117	17041-20001-38138	2242 S HOBART BLVD	90018	8	123B193   282	5058018014	[Q]RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.03502	-118.30766	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.Total pv system size: 6.16kW ungrounded.(22) 280W EnPhase IQ6 PLUS microinverters.(22) 360W pv modules.(2) 5kW Tesla Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44118	12041-10000-10620	3518 S TROUSDALE PKWY 1ST/2ND	90089	9	120A201    86	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.02157	-118.28415	Plan check T24 Energy for USC VKC Classroom remodel #100, 101, 102, 105, 106, 107, 108, 109, 110, 111, 200, 201, 202, 203, 205. 206, 207, 208, 209, 210, 211. No new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44119	13041-10003-36099	901 E 12TH ST	90021	14	123A211    87	5132014001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.03208	-118.24959	DELTA 2 CHANGES TO PERMITTED SET OF PLANSSMALL CHANGES TO LIGHTING SYSTEM AND ADDITION OF 2 100A  EMPTY PANELBOARDSCHANGES ARE CLOUDE AND MARKED AS DELTA 2	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44120	13041-20000-35610	6501 W HOLLYWOOD BLVD	90028	13	148-5A187 136	5547007010	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.10176	-118.33115	PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO RESTAURANT. OCCUPANY LOAD EXCEEDS 99.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44121	18041-20000-19842	4500 S BROADWAY	90037	9	112-5A203 180	5110005032	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Apartment			05/29/2018 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	05/24/2021 12:00:00 AM	ADDRESS	34.00269	-118.27814	Remodel of 5 units on second floor of (E) 2 story mixed use building.  New 800A 240/120V 1ph-3w service.  Building permit filed under 18016-10000-02644.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44122	14041-10000-35641	2420 N GLENDALE BLVD	90039	13	148-5A209 337	5440003002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM			PC Info Complete	05/28/2015 12:00:00 AM	ADDRESS	34.10064	-118.25903	Energy plan check for a comercial building (bank) T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44123	11041-10000-24421	19332 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.23457	-118.55484	1st time tenant, New restaurant.  Plan check for shell of building is currently in plan check.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44124	11041-10000-02857	1107 N BRONSON AVE	90038	13	144B189   644	5534010009	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.09102	-118.31808	replace damaged lighting systemplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44125	19041-10000-45873	5507 W HOLLYWOOD BLVD SUITE A	90028	13	148-5A193 129	5544005032	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM			PC Info Complete	01/22/2020 12:00:00 AM	ADDRESS	34.10192	-118.30983	PLAN CHECK FOR TITLE 24 ONLY. SCOPE OF WORK INCLUDES ADDITIONAL LIGHTING FIXTURES. TOTAL AFFECTED AREA: 1,546 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44126	19041-20000-01352	633 W 5TH ST 69th FLR.	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only in existing space Tenant Improvement add bar area extennsion to existing bar new lighting. Total area: 6450 sq ft. B#18016-10000-35817	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44127	17041-10000-12201	10654 N BECKFORD AVE	91326	12	207B121   442	2728002005	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM			Corrections Issued	04/21/2017 12:00:00 AM	ADDRESS	34.26398	-118.55099	PC for rooftop solar wirth 29 modules, 29 optimizers(solaredge), 1 solaredge SE6000 6KW centralized inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44128	14041-20003-18314	21308 W NASHVILLE ST	91311	12	210B105   187	2706032024	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	34.26892	-118.5959	Modification to approved set - as-built.  Removal of subpanel from proposed design.  $0 submittal fee is due to Senate Bill SB-1222. (((PV1.  Install roof-mounted solar array on SFD. System size: 10kW.(1) IG Plus Advanced 10.0-1 UNI transformered inverter(30) SunPower SPR-327NE-WHT-D pv modules)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44129	15041-10000-24488	8985 W VENICE BLVD UNIT K	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM			PC Approved	08/08/2015 12:00:00 AM	ADDRESS	34.02733	-118.39241	Full plan check only for a change of engineer, plan is resubmited with new design.Permit has been obtained on 14041-10000-20700	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44130	15041-10000-07124	335 N MARIPOSA AVE APT # 3	90004	13	138B197   132	5520025012	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Apartment			03/11/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.07733	-118.29968	PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A DWELLING. INTERCONNECT WITH MAIN SERVICE PANEL. (18) MODULES: YINGLI YL250P-29B(1) INVERTER: ABB PV1-3.6-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44131	18041-10000-35877	10675 W VANOWEN ST	91505	2	183B177    63	2466017020	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.19414	-118.36365	REMOVE INDOOR-OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44132	15041-20000-11196	13739 W ERWIN ST	91401	2	177B153   388	2239007027	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Expired	05/24/2017 12:00:00 AM	ADDRESS	34.18315	-118.43271	"""0$ permit fees due to senate bill 1222 ""pv1. Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  Two inverter system with four strings."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44133	14041-10000-35530	1115 E 103RD PL	90002	8	090B209   595	6051009015	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	PIN	33.94286317	-118.25600017	Installation of new roof mounted solar PV array.  Total system size = 3.8 kWac.  1 inverter with 17 modules (1 string; DC/DC converters used)  APN# used to initiate application.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44134	18041-10000-11654	2450 E CENTURY BLVD	90002	15	091-5A217 110	6046019923	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	33.94627	-118.22941	PLAN CHECK FOR NEW CORE AND SHELL TO 1 STORY RETAIL SPACE. NEW DISTRIBUTION EQUIPMENT RATED AT 1200A 120/208V WITH 2 PANELS. TOTAL AFFECTED AREA = 31,000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44135	10041-10001-18200	300 S FALCON ST	90744	15	024B205    40	7440019***	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	33.75794	-118.26677	REPLACING EXISTING BOOSTER (150 HP) AND TRANSFER (700 HP) PUMPS WITH ONE 1500HP PUMP. 2400 Volt, 3 Phase, Calss I Div II.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44136	13041-10000-30420	425 S LOS ANGELES ST	90013	14	129A213   246	5148008012	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.04695	-118.24694	PLAN CHECK FOR TITLE 24 ENERGY ONLY. SUBWAY STORE. 840 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44137	14041-10000-32767	508 E E ST	90744	15	030B209   847	7418010034	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	PIN	33.77564315	-118.25649975	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 11388 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44138	15041-20000-30797	7401 N DENSMORE AVE	91406	6	186B141   519	2206025013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.205	-118.47725	Plan check for PV1, 5.83 KW PV array, (1)inverter: PVI-5000-OUTD-S, (22)modules: #KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44139	13041-10000-32321	4912 N RHODES AVE	91607	2	168B165   194	2356026014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.15977	-118.40298	PV1, Install 5.5 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 22 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44140	15041-10000-16483	12600 N KENNY DR	91344	12	219B137    32	2609019026	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	05/28/2016 12:00:00 AM	ADDRESS	34.29895	-118.49856	PV1, INSTALL 14.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(43) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-5000 AND PVI-3.8	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44141	16041-10000-11713	10747 N RESEDA BLVD	91326	12	207B125   186	2717015017	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Expired	05/07/2018 12:00:00 AM	ADDRESS	34.26602	-118.53641	PV1, INSTALL NEW 3.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(17) MODULES: CANADIAN SOLAR CS6P-265P(1) INVERTER: SOLAREDGE SE3800 240V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44142	17041-10000-21755	465 S LA CIENEGA BLVD 1ST FLR	90048	5	135B173   130	4334019064	(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.06979	-118.37662	PC FOR T24 ENERGY ONLY, REPLACE LIGHTS WITH NEW LIGHTING IN PRIVATE DINING ROOM AND KITCHEN 1ST FLOOR. ADDITIONAL LOAD < 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44143	11041-20000-25454	5410 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM			PC Approved	03/16/2012 12:00:00 AM	ADDRESS	34.06204	-118.34668	Existing 10 story building.  Upgrading the AC units.  PLan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44144	19041-20000-51879	15211 W VANOWEN ST SUITE 204	91405	6	183B145   702	2220020020	(Q)C2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	03/12/2020 12:00:00 AM		Issued	03/12/2020 12:00:00 AM	ADDRESS	34.19412	-118.46446	New panels, power, and energy for medical office remodel inlcuding CT scanner.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44145	14041-20000-33208	3368 S ROBERTSON BLVD	90034	5	123B169  1495	4312012018	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.02916	-118.39127	permit fee $0.00 by state senate bill no. 1222Commercial roof mounted PV system with Enphase Microinveter, model M215-60-2LL. total size 27 KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44146	14041-10000-34279	1900 N SAN PEDRO ST	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Closed	09/30/2015 12:00:00 AM	PIN	33.74647892	-118.27942177	Plan check for power. Temporary installationof MVsubstation to power equipment to clean soil which was the site of a tank farm.Was already permited with 14041-40000-31136.{{{POWER EQUIPMENT FOR DIRT REMEDIATION (BERTH 118-120)}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44147	16041-20001-42417	7417 N LOUISE AVE	91406	6	186B133   692	2228015001	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.20522	-118.51003	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on detached garage of SFD. Interconnect with a 200A MSP. Derating main to 175A. 6kW ungrounded system. (25) 260W pv modules. There is an existing 3kW system on the SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44148	16041-10000-18416	7948-7952 N VAN NUYS BLVD	91402	6	189B149   634	2212028020	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM			PC Info Complete	05/25/2016 12:00:00 AM	ADDRESS	34.21559	-118.44851	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE. SCOPE INCLUDES TWO NEW PANELS, OUTDOOR LIGHTS FOR AN EXISTING CORE AND SHELL. TOTAL AFFECTED AREA IS 483 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44149	15041-20000-36560	7840 N WOODMAN AVE	91402	6	189B157   586	2214026148	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.21398	-118.4307	Plan check for PV roof mounted system. System size: 79kW and 8 inverters (8.2kW and 6.0kW) and 264 modules.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44150	19041-10001-38378	524 W 113TH ST	90044	8	087A201   204	6075026009	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.93179	-118.28361	PC FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS GOING FROM RAPID SHUT DOWN TO OPTIMZERS (SMA TS4-R). ALL CHANGES ARE CLOUDED UNDER DELTa 1. ORGINAL SCOPE OF WORK((PC FOR PV-1 SYSTEM. SYTEM SIZE IS 3.80.  12 MODULES WITH 1 SMA  AMERICA (SB3.8-1SP-US-40) INVERTER.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44151	12041-10000-03689	11682 W SAN VICENTE BLVD	90049	11	129B145    37	4265006063	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	05/10/2012 12:00:00 AM	ADDRESS	34.0536	-118.46464	1st time tenant, one story, power , energy, emergency, title 24. this is space 11682, range is 11682 to 11690.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44152	16041-20001-17597	20545 W PLUMMER ST	91311	12	198B109    19	2748003085	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM			PC Approved	08/22/2016 12:00:00 AM	ADDRESS	34.24291	-118.58123	08//22/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes include revisions to the lighting control system and installed lighting fixtures. All changes have been reflected onto the Title 24 Compliance Forms. *****Previous Work Description*****Plan chek for Title 24 only. T.I to existing idustrial building/wearhouse. New offices; restrooms. New lighting and receptacle. Total area: 10,235 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44153	17041-10000-32951	11844 W FOOTHILL BLVD	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.27365	-118.39446	PC FOR FIRST TIME TENANT FOR RETAIL SPACE FOR SEVEN ELEVEN STORESCOPE INCLUDES NEW PANELS CIRCUITS EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 2881 SQ.FT.   B#17016-10000-26369	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44154	18041-10000-40076	2275 W 25TH ST	90732	15	012B189   353	7563006019	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	02/20/2020 12:00:00 AM		Issued	02/20/2020 12:00:00 AM	ADDRESS	33.72714	-118.3272	Remodel and addition to existing clubhouse. new 300KVA TRANSFORMER AND DISTRIBUTION PANELS. PLAN CHECK FOR POWER & ENERGY. 9670 SQR FT. BLDG PERMIT: 18014-40000-05844	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44155	10041-10000-20340	10100 W SANTA MONICA BLVD suite#600	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM			PC Info Complete	10/13/2010 12:00:00 AM	ADDRESS	34.06191	-118.41691	Ti in an existing office. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44156	15041-10000-06615	1515 S WESTWOOD BLVD	90024	5	129B153    35	4324026037	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.05365	-118.44058	Plan check for power and energy. 1st floor renovation and regrigeration. Total area  = 9163 sq. ft. Existing panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44157	19041-20000-15893	14540 W FILMORE ST	91331	6	201B149    78	2647026001	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	PIN	34.25111819	-118.44942276	Plan check for a PV1 roof-mounted PV system. System size is 14.6 kWdc/11.8 kWac and consists of (2) inverters, (40) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44158	19041-20000-32367	920 W BLOOM WALK SUITE 701	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM			PC Info Complete	08/19/2019 12:00:00 AM	ADDRESS	34.01996	-118.28938	T24 PLAN CHECK FOR T.I. TO (E) SERVER ROOM. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 264 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44159	18041-10000-26254	9000 W 3RD ST	90048	5	138B169  1407		(T)(Q)R4-2-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.07338	-118.38815	PLAN CHECK FOR NEW FIRE ALARM SYSTEM USING 2 FIRE ALARM PANELS WITH 663 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44160	12041-20000-25875	901 S ABBOT KINNEY BLVD	90291	11	109-5A143 374	4286012008	C2-1-CA	West Los Angeles	Venice	Venice		2733.00, 2734.00	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	33.9927	-118.47312	Interior/Exterior Lighting for an existing commercial future tenant space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44161	15041-20000-15548	13856 W HUBBARD ST	91342	7	222B153   564	2517003001	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Expired	06/19/2017 12:00:00 AM	ADDRESS	34.30348	-118.43443	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (23) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44162	13041-10000-07978	2100 W MARTIN LUTHER KING, JR BLVD	90008	8	114B189   370	5022017043	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress Central Area		2340.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.01067	-118.31731	T24 FOR EXISTING 1-STORY BLDG. USE OF CHARTER SCHOOL. EXISTING SERVICE. 4087 SQRFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44163	19041-20000-44263	6950 N INDEPENDENCE AVE	91303	3	183B109   569	2138028038	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.19692	-118.59047	PLAN CHECK FOR NEW PV SYSTEM AND ESS. PV SYSTEM SIZE IS 7.92 KW DC/7.29 KW AC CEC. ESS SIZE IS 26.4 KWH.  SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, A SUB PANEL, AND (2) BATTERIES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44164	17041-30001-10873	941 N HIGHLAND AVE	90038	4	144B185  1015	5532012041	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM			PC Approved	04/18/2017 12:00:00 AM	ADDRESS	34.08829	-118.33879	04/18/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 forms.*****Previous Work Description*****PC FOR TI IN RESTROOMS ON 1ST AND 2ND FLOORS IN A TWO STORY COMM. BUILDINGTOTAL AFFECTED AREA OF 740 SQ.FT. SCOPE INCLUDES NEW LIGHT, RECEPTACLES AND PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44165	15041-20001-33423	16964 W ENCINO HILLS DR	91436	5	159B133    74	2287005059	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			Reviewed by Supervisor	10/23/2015 12:00:00 AM	ADDRESS	34.13479	-118.50213	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (50) modules, and (1) load center. Main service panel size is 400 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44166	14041-10000-14771	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LEVELS [[[ BASEEMENT, A, GROUND , STREET, 2ND AND 3RD.]]]]] RENOVATION IN SHERATORN AT THE BLOCK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44167	17041-20000-19005	20326 W KESWICK ST	91306	3	186B113    99	2114002009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.20957	-118.57627	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (33) AC modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44168	17041-10000-39290	2755 E LANCASTER AVE	90033	14	133-5A227 106	5202024901	A1-1-CUGU, RD2-1-CUGU	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.05725	-118.19499	PC for FA system for modular school building. Installing 28 devices, one FACP and one annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44169	19041-10000-14143	1707 W 265TH ST	90710	15	030B193    79	7411028025	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	33.78107	-118.30745	[e-plan] REVISION TO EXISTING PERMIT NUMBERSPV & BATTERY 19041-10000-01690DELTA 1 - PER LADWP ESR-- DC DISCONNECT FOR BATTERYADDED. SINGLE LINE UPDATED TO SHOW FEEDS FROMUTILITY AND STOREDGE INVERTER TO CRITICAL LOADCENTER WITH MECHANICAL INTERLOCK DEVICE.DC DISCONNECTS AND GROUND RODS ADDED AT DETACHEDSTRUCTURE PER INSPECTOR REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44170	13041-10001-29608	4831 W ST ELMO DR	90019	10	126B181   386	5067009034	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.0435	-118.34286	Expedited RSES plan check per applicant request. ((((PV1.  Install 2.75 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3000A-US.  11 modules: Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44171	15041-10000-16249	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.04896	-118.25139	PC FOR POWER AND ENERGY, TI, CHANGE OF USE FROM RETAIL TO BAR, OCCUPANCY LOAD IS MORE THAN 100. TOTAL AREA 6895 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44172	16041-10000-42315	1001 N HIGHLAND AVE	90038	4	144B185   883	5532028009	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.08902	-118.33878	Plan check for Title 24 only in existing space remove HID fixtures and replace with new LED fixtures. Total area: 42,825 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44173	15041-20000-34050	9250 N RESEDA BLVD STE 8	91324	12	198B125   208	2764012014	P-1VL, QC4-1VL, QP-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.23857	-118.53589	Title 24, plan check energy only. T.I. to existing restaraunt space.  New lighting, recepticles, cooking equipment, and HVAC.  Existing 400 A service to remain. Total area = 3,331 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44174	12041-10000-01358	10311 S WESTERN AVE 1-63	90047	8	091-5A193 277	6058007004	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Apartment			01/19/2012 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	33.94282	-118.30934	Plan check power, energy, for new 4-story 63-unit apartment building TO BE LOCATED IN THE METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44175	19041-10001-49368	1314 N CORONADO ST	90026	13	141A205   113	5424021005	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM			PC Approved	01/23/2020 12:00:00 AM	ADDRESS	34.0816	-118.26736	"PLAN CHECK ONLY. DELTA ""B"" CHANGES TO APPROVED PLAN FOR THE LOCATION OF THE JUNCTION BOX UNDER THE ARRAY PER INSPECTORS REQUEST. *****PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.38KWdc / 3.60KWac.(12)MODULES- LG ELECTRONIC LG365Q1C-V5(1)INVERTER-NINGBO GINLONG SOLIS-1P3.6-4G-US"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44176	12041-20000-11680	12800 W CULVER BLVD	90066	11	105B157   410	4221031009	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	33.98489	-118.42552	T24 and emergency lighting plan check for a remodel of rooms 231, 285 and 287 on the second floor of a two story office building.  INTERIOR REMODEL ON 2ND STORY TO AN EXISTING OFFICE INCLUDES NEW NON-BEARING PARTITIONS, CEILING RE-CONFIGURATION AND NEW FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44177	19041-20000-11104	13408 W SATICOY ST	91605	2	186B157   187	2303024024	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			Reviewed by Supervisor	04/26/2019 12:00:00 AM	ADDRESS	34.20854	-118.42494	Plan check for power and energy  800A Service to existing lighting manufacturing. total area: 3200 sq ft. see attachment for building records.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44178	16041-10002-41309	1717 E 7TH ST	90021	14	124-5A215  56	5164022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM			PC Approved	07/31/2017 12:00:00 AM	ADDRESS	34.03495	-118.23573	PC FOR CHANGES TO APPROVED SET UNDER DELTA 2 SCOPE INCLUDES REVISION TO EMERGENCY LIGHTS AND CHANGE TO CURRENT LIMITER AND TITLE 24 REVISIONS. PLAN CHECK ONLY!!!!Tenant improvement of (E) 1-story office and warehouse space wtih mezzanine.  No change of use. Plan check for power and energy; over 400A of newly connected load.  (E) 600A 120/240V 3ph-4w service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44179	11041-20000-23427	8211 W 3RD ST	90048	5	138B173   830	5511019034	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM			PC Approved	11/02/2011 12:00:00 AM	ADDRESS	34.07264	-118.36846	Plan check T24 Energy for showroom retail TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44180	16041-20000-19136	17108 W OAK VIEW DR	91316	5	165B133    26	2289032006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	06/25/2016 12:00:00 AM	PIN	34.15267941	-118.50664769	Plan check for PV roof mounted system. System size: 7.0kW with 21 modules and 1 inverter(7.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44181	11041-10000-05961	18441 W NORDHOFF ST	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			Not Ready to Issue	04/04/2011 12:00:00 AM	ADDRESS	34.23566	-118.53523	title 24 only .one story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44182	19041-20000-37570	15154 W STAGG ST	91405	6	189B145   585	2209033045	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.21196	-118.46354	800A 240/120V 3ph-4w service upgrade and consolidation of (4) existing 240/120V 1ph-3w overhead services.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44183	17041-10001-39904	1647 N MANDEVILLE CANYON ROAD	90049	11	135B137   621	4426001016	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	08/22/2023 12:00:00 AM	ADDRESS	34.06264	-118.49378	Adding a fourth power wall 13,5KWh energy storage system similar to the three that were added((((((Adding three energy storage systems to an existing PV system and a new load center.System consist of 3 powerwalls 13.5KWh each.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44184	18041-10001-14816	541 S SPRING ST #112 & 113	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.04657	-118.2507	SUPPLEMENTAL APPLICATION FOR A HIGH RISE BUILDING FOR CHANGING THE SOURCE FROM 90 MINUTES TO GENERATOR.PERMIT WAS ISSUED UNDER 18041-10000-14816	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44185	14041-10000-34856	1 WORLD WAY T81	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	33.94469	-118.39817	Inspector to verify custom chandelier.Plan check for power and energy. Full plan check for a first  time tenant restaurant (tenant space T81) at the LAX - TBIT  with 400-amp panel. Changes on plan include conductor sizes and T24 control clarification.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44186	11041-20000-04051	19500 W PLUMMER ST #D-5	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.2426	-118.55846	T.I. to existing space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44187	19041-10000-51927	9901 N HALLACK AVE	91324	12	201B117   104	2726021018	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.25031	-118.55704	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 11.55KWdc (11.03KWac) USING 35 PANASONIC VBHN330SA17 MODULES AND 35 ENPHASE IQ7X-96-2-US MICROINVERTERS.CONNECTED TO A 225 AMP NEW SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44188	16041-10000-03673	606 E VENICE BLVD BUILD. B	90291	11	108B145  1741	4237002007	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	33.98922	-118.46166	Exterior and interior alteration of (E) 2 story building. Install new lightings and control receptacles. PC for energy only, total area 10,129 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44189	12041-10000-25369	713-715 N VIRGIL AVE	90029	13	141B197   436	5539020030	[Q]C1-2D	Central	Hollywood	East Hollywood		1914.20, 1927.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.08404	-118.28701	existing commercial space to be developed for retai usePlan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44190	19041-10000-47529	1534 W VERNON AVE	90062	8	111B193   198	5016003030	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.00354	-118.30478	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44191	17041-10000-12652	1640 N AVALON BLVD	90744	15	036B205   233	7422002025	[Q]C1.5-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.79672	-118.26354	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 7,150 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44192	19041-20000-12268	8345 S WINSFORD AVE	90045	11	096B169   160	4125003030	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	33.96224	-118.38109	Plan check for PV roof mounted system, System size: 3.19KW DC, 3.0KW AC with 10 PV Modules and 1 inverter(3.0KW) center fed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44193	10041-10000-09106	705 E 9TH ST Basement	90021	14	124-5A211  15	5146025024	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			05/14/2010 12:00:00 AM			Corrections Issued	05/14/2010 12:00:00 AM	ADDRESS	34.03718	-118.24997	T.I. in basement (corridor, storage, restroom, gym, lounge, and spa areas) of an existing high rise building.  Install general and emergency light.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44194	13041-10001-16058	2601 S FIGUEROA ST	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM			PC Info Complete	10/27/2014 12:00:00 AM	ADDRESS	34.02804	-118.2763	changes to permitted set of plans; larger dynamometer tobe installed resulting in moreelectrical  power to be used Commercial TI for Auto Club-owned facility.  Reduction of office space to make room for expansion of emissions testing center and dynamometer.  Upgrade of restrooms to meet ADA compliance.  New panel rated 600 A bussing.  Power and energy plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44195	17041-20001-24657	1356 S ALBANY ST	90015	1	127-5A203 394	5135035014	CM-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.04184	-118.27479	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44196	16041-10000-38319	1087 S BROXTON AVE	90024	5	132B149    79	4363024002	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.06096	-118.44601	PC FOR TITLE 24. ENERGY ONLY FOR COMMERCIAL (RETAIL) SPACE.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES .TOTAL AFFECTED AREA 5108 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44197	16041-30000-09362	1735-1739 S WESTWOOD BLVD	90024	5	129B153   317	4324028047	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	34.05128	-118.43861	Title 24 plan check only.  Total area = 1,978 sq. ft.    T.I. to existing retail space.  Combine two retail spaces.  Existing power distribution equipment to remain.  New lighting and receptacles.  Building permit #16016-30000-05771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44198	16041-20000-10126	12423 N GLADSTONE AVE #27	91342	7	219B161   251	2525018057	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	34.29571	-118.4121	Plan check for energy only. TI to existing commercial building. New lighting (incl. emergency). 1,636sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44199	13041-20000-22770	15276 W COBALT ST PV-1	91342	7	225B145   329	2501009010	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.31127	-118.46495	PV-1. Plan check for microinverters. 34 microinverters for 7.31 kW total.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44200	16041-10000-39848	3084 S MOTOR AVE	90064	5	123B161   498	4316007009	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.03423	-118.41021	PC FOR FA SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44201	17041-10001-39647	16923 W VANOWEN ST	91406	6	183B133   917	2230010003	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.19408	-118.50178	08-01-2018 Changes to an approved set of plans, changes include update single line diagram and panel schedule to as built. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44202	17041-20004-39882	10727 W WILSHIRE BLVD 1-109	90024	5	132B153   123	4360033***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.06081	-118.43692	7/17/19changes to an approved set of plans.  changes to update plans and reflect field conditions.  this is plan check only.  ((((11/3/2017change of contractor.Plan check for power only.  Installation of new distribution board for installation of new car chargers in existing highrise residential building.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44203	17041-10000-29691	2683 E THORPE AVE	90065	1	145-5A219 255	5453005004	R1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.09246	-118.22537	PC FOR PV SYSTEM. USING CENTRAL INVERTER WITH POWER OPTIMIZERS. TOTAL OF 18 MODULES. 3.8KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44204	10041-10000-00366	1489 E 4TH ST	90033	14	127-5A219 300	5172020017	MR1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			01/08/2010 12:00:00 AM			PC Info Complete	01/22/2010 12:00:00 AM	ADDRESS	34.04272	-118.22409	TI - remodel of existing space - screen printing / industrial application - Permit is for new ckts and equipment on existing panels.  P/C is for Energy and emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44205	14041-20000-24308	13854 W MAGNOLIA BLVD	91423	4	171B153   466	2269006002	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.16466	-118.43527	$0 permit fee is due to Senate Bill SB-1222. PV1.  Install 14.0 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44206	16041-10000-09366	115 S ST ANDREWS PL #1-8	90004	4	138B193  1113	5516022015	R3-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	Apartment			03/17/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.0726	-118.3116	CONSTRUCT NEW 3 STORY 8 UNIT APT/ ROOF DECK AND SUBTERRAINIAN PARKING GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44207	14041-20000-19295	12405 W VENTURA BLVD	91604	2	162B165   191	2367018035	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.14302	-118.40327	T.I. to existing dental office.  Install new 200A service panel, panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44208	18041-20000-33131	4806 N SYLMAR AVE	91423	4	169-5A151 209	2248004018	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	08/27/2021 12:00:00 AM	PIN	34.15792067	-118.44633889	Plan check for power and energy for 11 units Multi residential 4 story building with 800 A Service and Total area: 3901 sq ft. B#17010-10000-03233Fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44209	18041-20000-07853	5317 S PACIFIC AVE	90292	11	099A149    10	4294007023	R3-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	33.96719	-118.45629	PLAN CHECK FOR A ROOF MOUNTRED PV SYSTEM. SYSTEM SIZE = 5.11 KVA CONSISTING OF 16AC MODULES(SUNPOWER SPR-X22-360-C-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44210	13041-20000-00181	7509 N SATSUMA AVE	91352	6	186B173   493	2410005018	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.20687	-118.36718	New 5.04KW rooftop mounted PV system for an existing single family residence.   System is ungrounded/transformerless and uses Solar Edge Optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44211	18041-10000-27212	12537 W SHERMAN WAY	91605	2	183B161    19	2324003038	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.20136	-118.40638	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44212	14041-20002-20954	3500 W WILSHIRE BLVD	90010	10	132B193   108	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM			PC Approved	12/01/2015 12:00:00 AM	ADDRESS	34.06157	-118.30077	Changed to approved set: New 400A breaker and Replace SB manufacture. Permit under 14041-20001-20954(Plans were lost. Permit will be pulled under supplemental.)((PC FOR POWER ONLY. NEW SERVICE AND DISTRIBUTION FOR FUTURE 2 STORY MINI MALL. EXISTING BUILDING WITH NEW ELECTRICAL CORE AND SHELL. PER BUILDING SUBMITTAL, PLAN CHECK FOR BUILDING EFFICIENCY BASED ON 2008 STANDARDS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44213	14041-20001-21443	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			12/03/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Closed	04/05/2016 12:00:00 AM	ADDRESS	34.19603	-118.45077	12/03/15Changes to an approved set. All changes made under delta D. Scope includes adding a new panel/feeder to the main distribution panel. Going from a 49 unit apartment building to 50 unit apartment building. (((Plan check for power and energy (2008 Energy Code). New 49-unit apartment building, 3-stories. Fee calcs provided by applicant - verify. Fire alarm variance filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44214	15041-20000-09875	4810 N BALBOA AVE	91316	5	168B133   256	2289019151	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	PIN	34.15777393	-118.50295447	PV1 ROOF MOUNTED SINGLE FAMILY DWELLING PHOTOVOLTAIC SYSTEM. TOTAL OF 33 MODULES. USING MICROINVERTER SYSTEM. USING ENPHASE M250 INVETER. TOTAL SYSTEM SIZE 7.9KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44215	14041-20000-35921	9728 N CREBS AVE	91324	12	201B121   405	2763023018	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.24721	-118.54365	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.9 KW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44216	16041-10001-40818	2570 S LINCOLN BLVD #103	90291	11	108B149  1026	4236031001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	33.99082	-118.44789	"PC FOR APPROVED SET TO REFLECT CHANGES OF FIXTURE TYPE ""A"" FROM CFL TO LED. SCOPE INCLUDES REVISED FLOOR PLAN ADDTION OF EMERGENCY LIGHTS AND REVISION TO TITLE -24  FORMS.THIS IS PLAN CHECK ONLY!!PC for energy only to an existing buiilding. Change of us from retail to yoga studio. Installing new lighting and power. Total sqft = 2766."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44217	16041-10000-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	33.94502	-118.40714	PLAN CHECK FOR POWER AND TITLE 24.  BUILDING PLAN CHECK #16016-10000-11866SCOPE OF WORK IS DENOTED BY DASHED LINES ON SINGLE LINE.  NEW BUS GATE AND FACILITY IMPROVEMENT FOR TERMINAL 3 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUSING OPERATION, AND OFFICE RENOVATION.  31 NEW PANELS TIED TO EXISTING ELECTRICAL DISTRIBUTION SYSTEM WITH ASSOCIATED LIGHTING AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44218	13041-10000-30923	282 S THORNE ST	90042	14	153A233   370	5492039021	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.03	Electrical	Electrical	Apartment			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/19/2013 12:00:00 AM	ADDRESS	34.11225	-118.18085	PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 10 modules: HANWHA # HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44219	13041-20000-08022	333 S HOPE ST #900	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	Change to lighting in an existing high-rise office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44220	18041-10000-47826	2814 N NORTH BROADWAY	90031	1	138A223    84	5204020003	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.07352	-118.21259	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44221	13041-20002-10958	5700 N CANOGA AVE 2ND FLR	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.17365	-118.59715	((9/12/2013: DELTA 3 CHANGES MADE TO APPROVED SET OF PLANS. CHANGES CONSIST OF TITLE 24 CHANGES ONLY IN ROOMS 221 AND 250. PLAN CHECK APPLICATION ONLY.))Changes to approved set of plans.2ND FLOOR REMODEL FOR OFFICE AREA, TOTAL AREA 18,000 SQ FT. PC FOR POWER AND ENERGY. NEW CONNECTED LOAD TO EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44222	14041-20001-24837	7010 S HOOVER ST Unit #5	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #5. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44223	12041-20000-22690	11601 N WILSHIRE BLVD # 300/325	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	PIN	34.0509267	-118.45996763	Install lighnting and receptacles to existing circuits and one ups unit to supply server unit in a remodel of existing tenant suites 300/325.  Plan check for T-24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44224	11041-10000-06507	4375 S GLENCOE AVE	90292	11	105B153    86	4212004004	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			PC Approved	04/06/2011 12:00:00 AM	ADDRESS	33.98565	-118.43823	addition to existing restaurant and and alterations	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44225	15041-10000-38135	1782 W 22ND ST	90007	8	123B197   167	5054001002	R3-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.03614	-118.29987	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44226	10041-20000-19871	16230 W BERTELLA DR	91436	5	168B137   792	2284016040	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.15363	-118.48732	Plan check for new ground mounted 50.32 KW Photovoltaic system single family dwelling with solar tracker ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44227	09041-10008-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM			PC Approved	04/25/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans for  temporary chiller/boiler yard at TBIT -GDN 056 and   GDN 124R1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44228	15041-10001-26002	4628 W ST CHARLES PL	90019	10	126B185   121	5071019036	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	Apartment			08/11/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.04504	-118.33873	Expedited plan check per applicant request.  PV2.  Install 2.65 kW roof-mounted utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44229	16041-20000-31890	2102 W COLORADO BLVD	90041	14	162A223   120	5686003018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.13897	-118.21215	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to gym and related t.i. with an occupant load of 45. Total lighting area = 3,812 sq. ft.Note: Building permit has been pulled under 16016-10000-17609	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44230	11041-10004-20700	3460 W 7TH ST	90005	10	132B193   388	5093025028	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Apartment			02/14/2013 12:00:00 AM			PC Approved	02/14/2013 12:00:00 AM	ADDRESS	34.05958	-118.3025	Modification to previously approved set of plans.  Change to lighting on the ground floor only, all other lighting to remain the same.  PLAN CHECK ONLY for Energy and Emergency lighting on the first floor.      <<<<CONVERSION OF 168 APARTMENTS IN AN EXISTING 13-STORY BUILDING TO 168 CONDOMINIUMS IN CONFORMANCE WITH VTTM 64165-CC-1A>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44231	11041-10000-07743	3465 W 6TH ST	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM			PC Approved	04/18/2011 12:00:00 AM	ADDRESS	34.06373	-118.29761	ALTERATIONS  COMMERCIAL BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44232	17041-10000-24608	127 S SAN VICENTE BLVD 3RD FLOOR	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Info Complete	07/20/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	OFFICE TI TO 3RD FLOOR. PC FOR T24 ENERGY ONLY. NEW LIGHTING IN SMALL OFFICE UPGRADES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44233	14041-10002-01677	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	34.21328	-118.45279	Delta 3 modifications to approved set.  Minor changes to HVAC loads.  (((Plan check for power and energy. Total Area for Indoor and outdoor lighting is 56695 sq ft. (31720 interior + 24975 exterior). New electrical systems throughout for fire damaged building. Not methane. GREEn building. Series rated for 65k for available 36KA.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44234	10041-10001-12355	1130 W C ST	90744	15	027B201    90	7417008038	M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM			PC Approved	07/19/2011 12:00:00 AM	ADDRESS	33.77182	-118.27581	Installing a new HPP (High Presure Pasturation) machine for State Fish Company,  New Service and panelboards. Plan check for power and energy.  <<<<<<<CHANGES TO EXISTING APPROVED SET OF PLANS,  ALL CHANGES ARE CLOUDED>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44235	17041-20000-08413	6430 W SUNSET BLVD 11TH FLOOR	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.09782	-118.32979	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CNN OFFICES. 11TH FLOOR. HIGH RISE. 320 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44236	13041-10000-35195	888 S HOPE ST	90017	14	127-5A209  28	5144020027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			12/19/2013 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.0452	-118.25996	Full plan check(Power and Energy) for a new high rise condos. 33 stories and 526 units.(Mehdi)    90 extra ckts added to compensate for pre cut check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44237	16041-10000-45091	11385 W EXPOSITION BLVD	90064	11	123B153   333	4260039902	PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2712.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.03423	-118.43994	PC for energy only. Outdoor title 24. Remove HID fixture and replace with new LED fixtures. Area: 13,200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44238	18041-20000-18419	14847 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29471	-118.45488	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.87kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44239	18041-20000-17420	240 N ROCKINGHAM AVE	90049	11	132B137   204	4406008001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	ADDRESS	34.05974	-118.49126	Plan check for power only. Project site is a new 2-story single-family dwelling. Work includes a new 800-amp service.Plan check only Electrical permit pulled under Building # 15010-30000-04622Note: Building application has been generated under 15010-30000-04622	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44240	14041-10000-01358	5700 W WILSHIRE BLVD 4TH FLR	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.06218	-118.35303	T24 PART 6 ENERGY FOR OFFICE BUILDING. SCOPE OF LIGHTING WORK LIMITED TO 4TH FLOOR, WITH PROJECTED AREA OF 6150 SQ FT. EMERGENCY LIGHTING ALSO IN SCOPE OF WORK. SCOPE OF WORK < 400A. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44241	11041-10000-03183	2415 E WASHINGTON BLVD	90021	14	118-5A217 116	5168009011	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	01/18/2012 12:00:00 AM	ADDRESS	34.01912	-118.22964	T-24 lighting plancheck for a change of usepermit fee is in inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44242	14041-20000-00764	8821 S HAAS AVE	90047	8	096A191   144	6036002021	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	33.95738	-118.31711	PV1 TRANSFORMERLESS SYSTEM. SOLAR OPTIMIZERS USED. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44243	17041-10000-21304	3000 W LEEWARD AVE	90005	1	132B197   364	5077018011	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.05857	-118.28933	REPLACING EXISTING PANELS IN THE UNITS LIKE TO LIKE. NO NEW LOAD ADDED IN THE UNITS.   SQUARE FOOTAGE REMAINS. PROVIDED TYPICAL PANEL AND PANEL FOR HOUSE LOADS UPGRADES. PROVIDED TITLE 24 FOR COMMON AREA ALTERATIONS.Phase 1: 17071-10000-21304Phase 2: 17071-10000-22126	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44244	13041-10000-17633	12887 W RUNWAY ROAD Units 1-6	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/03/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	33.97515	-118.42058	PLAN CHECK POWER AND ENERGY FOR NEW 6-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #1  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44245	16041-20001-28394	2859 W FRANCIS AVE 1-81	90005	1	132B197   554	5077022020	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.05692	-118.28826	12/18/2018changes to an approved set of plans.  changes to one subterranean parking, service load calculations and energy calculations.   this is plan check only.  (((((Plan check for power and energy. Project site is a new 7-story, 81-unit apartment building. Service size is 2,500-amps and total lighting area = 91,642 sq. ft.Note: Building application has been created under 15010-10000-01186)))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44246	10041-10000-24779	18433 W ROSCOE BLVD # 212	91325	12	192B125   578	2786022035	(Q)C1-1VL, (Q)P-1VL	North Valley	Northridge	Northridge South		1154.02	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	34.22091	-118.53469	T-24 and electrical for Interior tenant improvements for (E) medical office Suite #212:  non-bearing partitions and suspended ceiling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44247	14041-20000-14321	17087 W SAN JOSE ST	91344	12	207B133   836	2695010021	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.26127	-118.50549	PV1Install roof-mounted solar array on SFD. System size: 6kW(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(23) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44248	19041-20000-39856	252 S TAVISTOCK AVE	90049	5	138B145   579	4366019029	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.07124	-118.45961	PV1 PLAN CHECK FOR NEW ROOF PV AND ESS FOR EXISTING SFD. PV SYSTEM SIZE IS 4.95 KW DC/4.56 KW AC CEC AND ESS SIZE IS 13.5 KWG. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH MICROINVERTERS, 13.5 KWH BATTERY, AND A 200A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44249	19041-10001-14504	3201 E UNION PACIFIC AVE	90023	14	118-5A223 193	5169001014	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.01715	-118.21064	EXPEDITED.NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (3) SE5000H INVERTER AND (57) MODULES + OPTIMIZERS. TOTAL SYSTEM SIZE IS 20.24KWDC AND 17.2KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44250	18041-20000-13653	4525 W WILSHIRE BLVD 2nd Floor-corridor	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	Plan check for Title 24 only in existing corridor and elevator lobby T.I. lighting only. Total area: 1142 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44251	15041-10000-35150	5162 W MELROSE AVE	90004	4	141B193   612	5522007026	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Expired	11/17/2017 12:00:00 AM	PIN	34.08332684	-118.31320919	INSTALLING ONE NEW FIRE ALARM PANEL WITH EXISTING DEVICES TO A HOTEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44252	18041-10000-22755	9388 N REMICK AVE	91331	6	198B161   213	2629027026	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Issued	06/19/2018 12:00:00 AM	ADDRESS	34.23976	-118.41377	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44253	13041-10000-14624	380 W WORLD WAY T44AR	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK FOR POWER AND ENERGY. FIRST TIME TENANT AT THOMAS BRADLEY INTERNATIONAL TERMINAL. HUGO BOSS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44254	15041-20000-41326	5617 N WILLOW CREST AVE	91601	2	174B177   511	2415022008	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.17273	-118.36278	PV1 roof mounted solar installation interconnect with (E) 100 A MS.(12) SE F270-KZC-2Y(1) SE3800A-USPower optimizer is used.Submitted per applicant.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44255	18041-20001-05771	1415 S REEVES ST	90035	5	132A167   299	4306002010	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	05/06/2020 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.0547	-118.39672	Revisions to approved plans.  Redesign of (1) dwelling unit - revised loads, wiring details, etc. - and additional house panel loads.  (((New 25-unit 4-story apartment building.  2000 208Y/120V 3ph-4w service.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44256	17041-10000-11350	10432 S PARMELEE AVE	90002	15	090B209   855	6065004012	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	ADDRESS	33.94153	-118.25031	PC  FOR ROOF MOUNTED PV (SFD)TOTAL SYSTEM SIZE IS 3.8 KAC SOLAREDGE 3800H-USWITH OPTIMIZR SE-P300AND 11 MODULES SW-290UPDATED FEES!!!!!!	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44257	18041-20000-17216	524 N ARDMORE AVE	90004	13	141B193  1104	5520012018	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Apartment			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	09/21/2020 12:00:00 AM	ADDRESS	34.08076	-118.30152	Plan check for a fire alarm system for a new 8-unit, 2-story apartment building. Fire alarm system consists of (1) FACP and (5) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44258	19041-10000-15682	240-248 S WESTERN AVE	90004	10	135B193   112	5517007017	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2114.10	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	06/26/2020 12:00:00 AM		Permit Finaled	08/16/2021 12:00:00 AM	ADDRESS	34.06999	-118.30893	PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER FOR COMMON AREA SPACES FOR PROPOSED CORE AND SHELL SPACE. BUILDING HAS AN EXISTING SERVICE AND SWITCHBOARD. TOTAL SQ. FT. 9318	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44259	13041-10001-29795	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	CHANGES TO AN APPROVED SET. ADDING 4 NEW SMOKE DETECTORS AND A BATTERY SUPPLY. NOTE CHANGES ON DELTA 3.(((Installation of new fire alarm system in Loyola Marymount University Life Science tenant improvement to meet proper coverage per NFPA 72.  1 new fire alarm control panel and 324 devices. (conduit only pulled for P1,2,3 on 10/24/2013) )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44260	12041-20000-15972	8383 W 4TH ST	90048	5	138B173  1037	5511034017	R2-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	08/07/2012 12:00:00 AM	ADDRESS	34.07133	-118.37312	Roof mounted P.V. system (5.886 KWdc)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44261	17041-20000-09166	13267 W FOOTHILL BLVD	91342	13	219B157   604	2513027055	[Q]RD1.5-1-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.30099	-118.42289	energy check for outdoor t-24.  total square footage 37158.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44262	12041-10001-15811	8950 N GLENOAKS BLVD	91352	6	195B173   149	2408005031	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	34.2319	-118.36828	REVISIONS TO PERMITTED SET OF PLANSREMOVE  1PH 2-POLE PANELBOARD AND SUBFEED LOADS FROM AN EXISTING 3PH PANELBOARD. ALL  CHANGES ARE CLOUDEDPlan check for power and energy. Change of use from industrial to catering. 7489 indoor sqft and 25196 outdoor sqft. Commercial low rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44263	17041-20000-13977	12807 W MATTESON AVE	90066	11	111B153   987	4236015022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			05/04/2017 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	33.99858	-118.4393	Plan check for power and energy. Project site is a new 3-story, 10-unit apartment building over 1 level of on-grade parking garage. Work includes an 800-amp service and a total lighting area of 9,701 sq. ft.Note: Building application has been generated under 16010-10000-05615	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44264	16041-10000-09621	707 N ALVARADO ST	90026	13	138A207    44	5402038005	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Info Complete	07/25/2017 12:00:00 AM	ADDRESS	34.07399	-118.26585	Full plan check for a 5story  67 unit apartment. Scope includes 1600 Amp service, 120/208v 3phase 4wires.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44265	13041-10000-35893	1249 S GRAND AVE # 1-#112	90015	14	126A207   160	5139022014	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			12/24/2013 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.03937	-118.2645	FULL PLAN CHECK FOR POWER AND ENERGY TO NEW 7-story 112 UNITS apartment building with commercial on the ground floor and 2-level of subterranean garage; PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 83,208 SQ FT (INDOOR + OUTDOOR) . UNGROUND SERVICE, LOCATED IN METHANE ZONE.building permit: 13010-10000-03579	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44266	15041-20000-22821	6060 W WILSHIRE BLVD	90036	4	135B177   526	5086009014	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.06273	-118.36103	Paln check for Fire alarm system. Total fire alarm devices: 274 and 1 fire alarm panel. Plan submitted to fire department	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44267	11041-10000-00708	15533 W VIA DE LAS OLAS	90272	11	123B125   146	4412023019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	05/10/2011 12:00:00 AM	ADDRESS	34.03583	-118.53196	New 11.7 Kw PV system. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44268	18041-20000-24222	818 W 7TH ST Suite 1100	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.04895	-118.25943	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement of the 11th floor. Total lighting area = 9,791 sq. ft.Note: Building application has been generated under 18016-10000-04127	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44269	13041-20000-18734	12451 W ALBERS ST	91607	2	174B165   875	2347002019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.17044	-118.40474	PV1 MICROINVERTER STANDARD PLAN. 32 PANELS TOTAL SYSTEM 6.9 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44270	11041-20004-03572	340 S MAIN ST BLDG B	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM			PC Approved	09/15/2011 12:00:00 AM	ADDRESS	33.99519	-118.47673	REVISION TO APPROVED PLANS FOR BUILDING B T24 ENERGY CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44271	19041-10000-13366	7115 S HAAS AVE	90047	8	102B189  1212	6016032023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	33.97516	-118.31697	PV1 - NEW ROOF MOUNTED 5KW (AC) PV SYSTEM Includes (19)Hanwha Q-cell W/P320 optimizers. (1) central inverter (solar edge SE5000H). (1) 30A disconnect switch.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44272	14041-20001-26959	6100 N FIGUEROA ST	90042	14	153A231   348	5492026027	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM			PC Approved	10/30/2014 12:00:00 AM	ADDRESS	34.11212	-118.18766	EXPEDITE PER APPLICANT REQUEST[[[PV2Install a roof-mounted solar array on roof of commercial office building, inteconnect at DWP transformer vault. System size: 30kW.(3) ABB PVI-10.0-I-OUTD high frequency trasformered inverters(136) SunModule SW270 MONO pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44273	15041-10000-07086	9716 W CASHIO ST	90035	5	129B165   278	4307006068	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Expired	04/04/2017 12:00:00 AM	ADDRESS	34.05223	-118.39926	PV1, INSTALL 6 KW DC ROOF -MOUNTED SOLAR ARRAY ON A SINGEL FAMILY HOME. INTERCONNECT WITH MAIN SERVICE PANEL.(31) MODULES: YINGLI YL255P-29B(1) INVERTERS: ABB PV1-6000-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44274	17041-10001-18055	5123 N WILBUR AVE	91356	3	171B121   405	2161004047	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.1637	-118.54556	SUPPLEMENTAL APPLICATION FOR OFF HOUR PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44275	16041-10004-16336	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			PC Info Complete	12/11/2018 12:00:00 AM	ADDRESS	34.08865	-118.34299	FULL PLAN CHECK DUE TO CHANGES TO AN APPROVED SET OF PLANS. CHANGESTO GROUND LEVEL, 6TH, 7TH AND 8TH FLOOR. INSTALLING HVAC EQUIPMENT, LIGHTING AND OTHER LOADS. CHANGES ARE NOTED AS DELTA 10-13See comment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44276	13041-20000-27712	6413 N PLATT AVE	91307	12	180B093   780	2033010034	C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.18715	-118.64297	Change of use for a nail spa.  Change to lighting and receptacles.  Load is 70 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44277	14041-20001-19908	23700 W INGOMAR ST	91304	12	189B089   384	2020014039	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM			PC Approved	08/04/2014 12:00:00 AM	ADDRESS	34.21146	-118.64447	Expedite per customer request(((10.75KW PV1 roof-mounted system with (50) YingLi YL250P modules and Enphase M215 micro inverters.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44278	17041-10000-06028	20303 W GILMORE ST	91306	3	180B113   543	2136024023	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.18924	-118.57558	PC for  a PV 1 roof mounted solar system installation. New 7.6 KW inverter connected to 24 solar modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44279	09041-20003-11844	155 S MAIN ST	90012	14	130-5A213  24	5149001902	PF-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.05125	-118.24458	T24 lighting plan check for revised lighting system.  Remove type A fixtures, revise low voltage track lighting, and new type F fixtures.   No change in the emergency lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44280	10041-30000-02917	831 S HOPE ST A111	90017	9	129A209   267	5144020194	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	06/09/2010 12:00:00 AM	ADDRESS	34.046	-118.25993	PLAN CHECK POWER ONLY.  FIRST TIME TENANT FOR YOGA STUDIO/GYM (SUITE A111). T-24 ENERGY ON SEPERATE APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44281	11041-10000-09404	633 W 5TH ST 37th fl	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44282	16041-20000-41847	642 S BURNSIDE AVE	90036	4	135B181   779	5508011021	[Q]R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.06362	-118.34919	Plan check for installation of solar pv system, roof-mounted on apartment building.30kW (10*3) ungrounded system. (86) 360W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44283	15041-10000-07420	444 S SAN VICENTE BLVD 7th Floor	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Issued	09/14/2015 12:00:00 AM	ADDRESS	34.07021	-118.37547	Remodel and upgrade of 7th floor medical office in (E) commercial medical highrise.  Expansion and remodel of therapy room, conversion of consultation room and office into charting room, and conversion of (E) offices to treatment rooms.  Building permit filed under 15016-10000-04966	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44284	17041-10000-40086	411 E 120TH ST 1-8	90061	15	084B205  1139	6083029027	R3-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			11/06/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	33.92386	-118.26699	Plan check for service upgrade to 600A  to feed 5 separate appartment Buildings. Main service at 411 E. 120th StreetVariances submitted for having multiple feeders supplying other buuildings	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44285	15041-10000-43277	17383 W SUNSET BLVD A450	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	PC for energy only, TI to a commercial building (4th floor). Installing new lighting and power in the open office spaces. Total sq. ft. 2190.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44286	14041-10001-20381	4297 S CRENSHAW BLVD	90008	8	114B185  1064	5024007023	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM			Corrections Issued	08/13/2014 12:00:00 AM	ADDRESS	34.00548	-118.33408	Title 24 plan check only.  Installation of outdoor lighting on existing commercial retail building.  Total area = 3,780 sq. ft. (hardscape)Building permit submitted prior to title 24 part 6 effective date.  14016-10000-00724Master permit:  EXPRESS PERMIT.REPLACING FACADE LUMINARIES ON A BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44287	19041-10000-27365	5795 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	33.93216	-118.3839	ENERGY PC FOR CASTER  DECK  INSTALLATION TO INTERIOR OF BUILDING LAX, AREA OF SCOPE 21,705SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44288	17041-10000-10196	1051 N HIGHLAND AVE	90038	4	144B185   788	5532028012	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.09026	-118.3388	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 11215 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44289	10041-10000-07587	11115 W HARTSOOK ST	91601	4	171B173   709	2353005021	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Apartment			04/26/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.16403	-118.37295	PLAN CHECK POWER AND ENERGY FOR NEW 24 UNIT APT, 3 STORIES ON TOP OF PARKING GARAGE.  MODIFICATION TO SEPERATE FIRE ALARM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44290	18041-10001-02175	6100 N SEPULVEDA BLVD	91411	6	177B145   400	2242025025	M2-1-RIO, M3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Approved	04/11/2018 12:00:00 AM	ADDRESS	34.18076	-118.46437	Changes to an approved set of plans, Changes are noted under delta clouded areas dated 03/19/18. Scope of work includes addition of merchandise pick up (added new lighting and circuits)___________________PC for power and energy for medical optical/hearing exam rooms, offices and retail TI inside Cosco. Installing two new panels, receptacles, lights and equipment. Total area is 1518sqft. B# 17016-10000-33754.TI WITHIN 2788 SQ FT OF EXISTING 152,144 SQ FT BUILDING (COSTCO) NEW OPTICAL EXAM AND RECEPTION ROOMS, OPTICAL KIOSK, PHOTO CENTER, HEARING AID CENTER; INCLUDES DEMO, STRUCTURAL; NEW PLATFORM FOR AC UNIT ON ROOF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44291	12041-10000-08113	719 N YALE ST 1-60	90012	1	133-5A213  25	5407024005	R4-1	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Apartment			04/10/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.06189	-118.24178	new fire alarme for new apartment building, 5 stories, 573 devices  and 2 panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44292	16041-30000-09090	19626 W NORDHOFF ST	91324	12	198B117   223	2783028004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.23527	-118.56116	Installation of new fire alarm system in single story restaraunt building.  Total system size = 1 FACP + 10 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44293	12041-10000-16314	7803 1/2 W BEVERLY BLVD	90036	5	138B177   437	5527038001	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM			PC Approved	07/13/2012 12:00:00 AM	ADDRESS	34.07628	-118.3596	INSTALL ELECTRICAL FOR WALK-IN COOLER. TO INCLUDE (8) OUTLETS AND (2) LIGHTS UNDER EXISTING CIRCUITS.  This is title 24 energy only , permit under 12041-1000-15643 issued.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44294	14041-20000-09566	16357 W PLUMMER ST	91343	12	198B137    32	2677020013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.24309	-118.48919	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44295	18041-10000-26206	5533 S EA WAY	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	09/15/2020 12:00:00 AM	ADDRESS	33.97374	-118.42896	Core and shell drawings. New 6 Story office building over 2-story subterranean garage.   Plan check for power and energy.  New 4000A 480Y/277V service with emergency generator and fire pump.  Not a highrise per applicant - verify with building permit.  Building permit filed under 16010-10000-02180.This is a major change from the original plans that were approved and permitted under 16041-20000-27187.Plan Check Only. The original permit is active except for the new added items.PLAN CHECKER TO VERIFY ENGINEER FROM ORIGINAL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44296	16041-10000-30859	801 S HOOVER ST	90005	1	132A201    52	5077021001	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.05738	-118.28444	PC FOR POWER AND ENERGY FOR A NEW GAS STATION CONVENIENCE STORE AND RETAIL SPACE. SCOPE INCLUDES A NEW 800A 120/240V 3 PHASE 4 WIRE SERVICE, NEW PANELS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 20526 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44297	10041-10000-02604	865 S FIGUEROA ST 31st fl	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	34.04653	-118.26275	Tenant improvement in office areasplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44298	14041-10000-11470	3650 W MARTIN LUTHER KING, JR BLVD #  283	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	TENANT IMPROVEMENT IN BEAUTY DALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44299	11041-10000-21712	4440 N VANTAGE AVE	91604	2	165B165   200	2364002051	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			10/11/2011 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.15143	-118.39737	NEW 30-UNIT APARTMENT WITH GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44300	17041-20000-00511	15821 W VENTURA BLVD Suite 545	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM			PC Approved	01/06/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for Title 24 only. Project site is an suite within an existing high-rise commercial building. Project scope is a tenant improvement. Total lighting area = 2,117 sq. ft.Note: Building permit has been pulled under 16016-10000-25958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44301	18041-20000-46991	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.04994	-118.41129	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of (4) ATSs for Phase I of project.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44302	17041-20002-45980	9601 N MASON AVE	91311	12	201B109   284	2748003080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM			PC Info Complete	02/08/2019 12:00:00 AM	ADDRESS	34.24457	-118.57997	2/8/2019changes to an approved set of plans.  changes noted delta 3 only.  changes to include addition of new extractor and vacuum forming machines with associated circuits.  plan check for power.((((Revisions to approved set.  Miscellaneous changes to SLD configuration.  (1) 300A feeder changed to (2) 200A feeders to accommodate equipment purchasing.))))  (((PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT FOR STORAGE WAREHOUSE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44303	15041-10000-27005	12700 W MILLENNIUM #48	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1 1.5KW roof-mounted system with (6) (SPR-X20-250 Sunpower AC- modules interconnecting through a sub-panel. Application is  plan check only, permit fee is paid under 15041-90000-26264.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44304	18041-10001-26790	3602 S 6TH AVE	90018	10	120B189  1229	5044027001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM	ADDRESS	34.02274	-118.32345	[[CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING MODULE TYPE TO SC320 AND ADDITION OF 1 MODULE.]]]PLAN CHECK FOR ROOF MOUNTED 3.3KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(PVI-3.3-OUTD-S-US-Z-A) WITH 10 PANELS(SOLARCITY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44305	16041-10000-37323	380 WORLD WAY LV 4-spc T-19	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR TITLE 24, ENERGY ONLY. SCOPE INCLUDES NEW LIGHTING AND JBOXESTOTAL AFFECTED AREA IS 1800 SQ.FT.  ( INDOOR COMMERCIAL SPACE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44306	19041-10000-19979	11233 N BORDEN AVE UNIT 41	91331	7	210B161   684	2536010***	(Q)RD2-1-CUGU, (Q)RD3-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.2737	-118.4062	PC for PV-1 system. system size is 5.49 kW. consists of 18 modules (canadian solar) w/(18) 320p optimizers. (1) SE5000h solaredge inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44307	18041-20002-10393	1660 W 3RD ST	90017	1	133-5A205 190	5153008017	C2-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	01/04/2023 12:00:00 AM	ADDRESS	34.06052	-118.26744	"9/13/2018changes to an approved set of plans.  changes noted delta 8. addition of panel ""K"", water heater, and associated circiuts only. Plan check for power only.((((MEDICAL CLINIC TI WITH CRITICAL CARE PATIENT AREAS.  Plan check for power and energy.))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44308	13041-10000-02057	13751 W HUBBARD ST	91342	7	222B153   124	2509014093	QR3-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM			Reviewed by Supervisor	02/19/2013 12:00:00 AM	ADDRESS	34.30578	-118.43247	POWER AND ENERGY.  ADDITION OF 2490 SF FOR REC ROOM TO EXISTING 6-UNIT APT. BLDG/MANAGER'S OFFICE.(plans have been revised, new plan check application has been generated.)13041-10000-08538	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44309	12041-20000-23776	16432 W MIDWOOD DR	91344	12	216B137   461	2610019026	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.02	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.28573	-118.4903	Single family dwellign solar PV installation. Two strings with transformerless inverter (Power One). System size is 4.4kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44310	15041-10000-34411	1053 S CRENSHAW BLVD	90019	10	129B189    95	5082027025	C2-1-O	Central	Wilshire	Olympic Park		2127.02	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.05336	-118.32396	T-24, TI TO AN (E) OFFICE SPACE 2 STORY BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. TOTAL SQ. FT. 4693	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44311	16041-10001-20095	301 W OLYMPIC BLVD Loit LA	90015	14	127-5A209 251	5139004026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM			PC Info Complete	10/05/2016 12:00:00 AM	ADDRESS	34.04182	-118.25852	10/03/16Changes to an approved set of plans. All changes are clouded under Delta 1. Changes include replacing/adding lights, and adding new receptacles. (((((((Full PC, Change of use from Retail to Restaurant in (E) MIxed use Build. New connected load < 400A, total area: 7,662 sq.ftB# 16016-10000-09083	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44312	14041-10004-32423	1900 S SAWTELLE BLVD	90025	11	126B153   469	4261031023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM			PC Info Complete	03/09/2017 12:00:00 AM	ADDRESS	34.04236	-118.44464	construction is on going ; 8KW OVEN IS ADDED TO EACH APT UNIT; SERVICE LOAD WAS CALCULATED USING THE ALTERNATIVE METHOD EACH TIME; THE REFRIGERATOR CIRCUIT WAS REMOVED LEAVING THE SERVICE CALCULATION LESS THAN THE ORIGINAL VALUE; THE UNIT CBs WERE CHANGED TO 125A as THE APT UNIT LOAD INCREASED  WITH THE ADDITION OF THE OVEN.(((((((((NEW 52 UNIT APARTMENT PLAN CHECK FOR POWER AND ENERGY. 3 LEVELS OF UNDERGROUND PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44313	14041-20000-20986	4201 N CLYBOURN AVE	91602	4	165B181   499	2424037016	A1-1XL, R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Expired	09/06/2016 12:00:00 AM	ADDRESS	34.14568	-118.34656	Renovation of the kitchen area of the existing building (Lakeside Golf Club).  Install indoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44314	17041-10000-38011	501 S BOYLE AVE	90033	14	126A221    18	5174002020	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.04125	-118.2198	Alterations in classrooms and restrooms on 1st floor- new luminaires using existing branch circuitsPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44315	14041-20001-11785	7225 W HOLLYWOOD BLVD	90046	4	147B181    96	5548001018	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Apartment			05/02/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.10174	-118.34715	PC FOR T-24 ENERGY ONLY.  REPLACEMENT OF FIXTURES TO AN APPROVED SET OF PLANS #140412000011785.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44316	13041-20000-13426	6556 N VAN NOORD AVE	91606	2	180B161   627	2326003001	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.19005	-118.41468	pv1 single family dwelling. total system size 1.7 kw. using microinverter standard plan enphase m215. 8 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44317	10041-10000-22099	310 W WASHINGTON BLVD BLDG #4	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 7 UNIT TOWN HOME.   (BUILDING #4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44318	15041-10000-31490	6300 W WILSHIRE BLVD STE-700	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.06319	-118.36591	Energy plan check for an office (STE 700) T.I  located at a high rise building. Scope includes new lighting, receptacles and (1) new panel; Tatal 6794-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44319	14041-10000-23146	333 S GRAND AVE 26TH FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR POWER AND ENERGY.TENANT IMPROVEMENT (+/- 22,108 SQFT).  PLAN CHECKER TO REVERIFY THE FEES.B# 14016-10000-17009	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44320	14041-20000-34793	20336 W CORALINE CIR	91311	12	207B113   127	2707018009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.26358	-118.57675	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.46 KW DC.(32) SUNPOWER SPR E20 MODULES(2) AURORA PVI-5000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44321	17041-10000-11000	6606 N VARIEL AVE	91303	3	180B105    44	2148029009	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			05/18/2017 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.19029	-118.59257	PC FOR POWER AND ENERGY. NEW 7 STORY 277 UNIT APARTMENT BUILDING OVER 1 LEVEL OF BASEMENT PARKING. SERVICE 5000A, TOTAL AREA 410 537 SQ FT.B # 16010-10001-04179 *****FIRE ALARM VARIANCE TO BE FILED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44322	17041-10000-46584	3125 W 54TH ST	90043	8	108B185   340	5006013001	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	33.9933	-118.32769	REPLACEOUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44323	12041-20000-17886	4371 S GLENCOE AVE	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	33.9857	-118.43834	energy plan check yogurtland	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44324	11041-10001-25397	808 E 62ND ST	90001	9	105B205   803	6007010008	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.00	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	33.98312	-118.26075	New 49KW rooftop photovlotaic system for an existing commercial building.   218 panels and 2 inverters.  (((Re-plan check to replace set of drawings lost by contractor.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44325	13041-10000-32248	13918 W CALVERT ST	91401	2	177B153   596	2239017009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Expired	12/22/2015 12:00:00 AM	ADDRESS	34.18202	-118.43622	PV1, Install  4.50 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 18 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44326	15041-20000-30144	809 S BUNDY DR 1-50	90049	11	129B141   411	4264010***	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			09/11/2015 12:00:00 AM			Ready to Issue	09/18/2015 12:00:00 AM	ADDRESS	34.05	-118.47214	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is a tenant improvement. Total lighting area = 4,410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44327	14041-20000-15176	11310 W SHERMAN WAY Bld. #1	91605	2	183B173   112	2319001006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	PIN	34.19989971	-118.37702755	T.I. to existing building #1.  Install news 1200A service and panels. Plan check for power only.Note: Application for Bld. #2 is under 14041-20000-15179	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44328	16041-20000-37000	6635 N FALLBROOK AVE	91307	12	180B097   170	2038040005	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.18998	-118.6262	new fire alarm system 149 devices plus fa panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44329	19041-30000-07914	445 S FIGUEROA ST 18th Floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for Title 24 only. Project site is the 18th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 15,555 sq. ft.Note: Building permit has been issued under 19016-10000-03001	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44330	19041-20000-41159	20819 W PINECONE CIR UNIT #18	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.29587	-118.58758	PV roof mounted system, PV system size: 4.2KW with 12 AC Modules connected to main panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44331	12041-10000-16689	5250 N LANKERSHIM BLVD	91601		171B173   367	2350018086							Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM			PC Approved	07/20/2012 12:00:00 AM	ADDRESS	34.16668	-118.37545	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR CLASSROOM TI ON THE 3RD AND 5TH FLOOR. EXISTING ART INSTITUTE SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44332	18041-20000-11472	8730 N ENCINO AVE	91325	12	195B129   394	2768015004	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.22959	-118.51558	Plan check for a PV1 roof-mounted PV system. System size is 13.2 kWdc/12.14 kWac and consists of (1) inverter, (40) modules, (1) load center, and (1) Tesla PowerWall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44333	18041-10000-26210	3742 S FLOWER ST	90007	9	117A201    14	5037030023	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.01663	-118.28178	PLAN CHECK FOR TITLE 24 ONLY FOR - Change of use from Restaurant to Restaurant/Retail. (Occupant Load shall remain at 99) - TOTAL AFFECTED AREA = 6525 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44334	18041-20000-04837	2414 E MICHIGAN AVE unit 1	90033	14	127-5A223  81	5180002023	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Closed	04/26/2018 12:00:00 AM	ADDRESS	34.0449	-118.20834	PV2.  Reinstallation of 2.25kw AC pv system interconnected with msp.this is system 1 of 3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44335	12041-20000-30523	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM			PC Approved	12/19/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check for energy only. High rise commercial. Suite 3300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44336	17041-20000-11364	12011 W VICTORY BLVD	91606	2	180B165   699	2322007055	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.18684	-118.39489	PLANCHECK FOR POWER ONLY. NEW SERVICE UPGRADE TO 800 AMPS AND TENANT METERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44337	15041-20000-30675	8940 N CORBIN AVE	91324	12	195B117    34	2783025080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.23325	-118.56211	Plan check for Title 24 only. Project site is an existing commercial space (gym). Project scope is a tenant improvement. Total lighting area = 3,579 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44338	14041-10000-04459	6255 W SUNSET BLVD STE 170	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	TI to commercial retail space - interior expansion into adjacent tenant space for Coffee Bean & Tea Leaf.  Title 24 plan check for changes to interior lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44339	15041-20000-37497	23338 W SCHOENBORN ST	91304	12	192B093   387	2005017004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Expired	12/07/2017 12:00:00 AM	ADDRESS	34.2201	-118.636	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (40) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44340	19041-10000-53295	755 S SPRING ST	90014	14	127-5A211 157	5144015240	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			Corrections Issued	01/02/2020 12:00:00 AM	ADDRESS	34.04336	-118.25369	FULL PLAN CHECK FOR A FIRST TIME TENANT. SCOPE INCLUDES NEW EQUIPMENT CONNECTED TO EXISTING 2500A SERVICE. SCOPE ALSO INCLUDE A 112.5 KVA TRANSFORMER. TOTAL AFFECTED AREA IS 38,793 SQ.FT B#19016-10000-41002FIRST TENANT BUILD-OUT OF CORE AND SHELL SPACE, CHANGE OF USE FROM RETAIL TO RESTAURANT (4,867SF) WITH OUTDOOR PATIO SEATING(95SF), WITH HOOD SUPPORT AND MECHANICAL INITS ABOVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44341	18041-10001-32620	4641 N VISTA DE ORO AVE	91364	3	168A111   102	2174015027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM			PC Approved	09/14/2018 12:00:00 AM	ADDRESS	34.15394	-118.58137	Expedite per applicant resquest.(((PV1 16KW AC roofmounted system with (56) microinverter and modules interconnecting through the load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44342	15041-20000-21209	13006 W CALVERT ST	91401	2	177B161   683	2331022017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Expired	07/31/2017 12:00:00 AM	ADDRESS	34.18112	-118.41609	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:  6KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44343	17041-10001-04631	20105 W RINALDI ST BLDG S3	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Closed	04/23/2021 12:00:00 AM	ADDRESS	34.27543	-118.57209	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding landscape lighting, exterior lights, revising title 24 calculations, and revising panel schedules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44344	17041-10000-27785	1155 W TEMPLE ST	90012	1	135A211   116	5160024013	CW	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.06466	-118.25231	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY. TOTAL SQAURE FT 44150.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44345	15041-20000-19707	300 S GRAND AVE 16TH FLR	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	PC FOR NEW LIGHTING. T24 ENERGY ONLY. TOTAL AREA 1550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44346	15041-10000-15153	700 W 7TH ST 3RD FL	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	RENOVATION AND UPGRADE AT A MACY'S STORE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44347	17041-10000-31832	3840 S CRENSHAW BLVD	90008	10	117B185   751	5033003016	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.01618	-118.33474	OFFICE TI. PC FOR ENERGY ONLY FOR T24 UPGRADES. INSTALLING NEW PANELS, RECEPTACLESLIGHTS AND EQUIPMENT. TOTAL AREA OF 11971SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44348	19041-10000-47381	510 S HEWITT ST	90013	14	127-5A215 437	5163021***	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Apartment			11/18/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	10/10/2020 12:00:00 AM	ADDRESS	34.04143	-118.23485	T-24 PLAN CHECK FOR A TENANT IMPROVEMENT OF AN EXISTING ROOFDECK POOL AREA. SCOPE INCLUDES NE RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 6,765 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44349	10041-10000-25799	3310 S CENTRAL AVE	90011	9	117A209   419	5114026***	(T)(Q)C2-1L	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	01/03/2011 12:00:00 AM		Permit Finaled	08/06/2011 12:00:00 AM	ADDRESS	34.01319	-118.25635	TI for a coffee shop, no cooking. EPC is for Energy & T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44350	13041-10000-35017	21800 W VICTORY BLVD	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.18712	-118.60325	"PLANCHECK FOR POWER AND ENERGY FOR New 1 story retail ""COSTCO"".BUILDING PERMIT #13010-10000-02749, 13010-10001-02749"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44351	16041-10002-42002	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM			PC Info Complete	02/05/2018 12:00:00 AM	ADDRESS	34.32381	-118.49103	PC FOR REVISIONS TO APPROVED SET TO REFLECT FIELD INATALLATION. SCOPE INCLUDES ADDITION OF WATER HEATER AND 200 DISCONNECT AHEAD OF LC PANEL . PERMIT TO BE PAID FOR THE NEW WATER HEATER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44352	09041-10002-02345	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.04896	-118.25139	AS-BUILT SET OF PLANS INCLUDES CHANGES MADE DURING CONSRUCTION :  TWO NEW PANELBORDS FOR NEW CIRCUITS; RENAMED A FW PANELBORDS; EXCLUDE CORRIDORS , STAIRWAY AND OFFICES PLAN CHECKED ON SEPARATE APPLICATION; DELETED A FEW KITCHEN CIRCUITS AS THE APPLIANCES ARE GAS TYPE ; TITLE 24 PLAN CHECKED FOR AREAS AS IS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44353	15041-20001-16553	565 N KENTER AVE	90049	11	135B137   132	4426037002	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM			PC Approved	06/23/2015 12:00:00 AM	ADDRESS	34.06899	-118.48766	Expedite per applicant request[[[[[Plan check for PV roof mounted system. System size 11.4kW with 35 modules and 1 inverter (11.5kW).]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44354	14041-10000-19616	1200 S CLUB VIEW DR 9 South	90024	5	135B157   112	4327024***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			07/22/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.06748	-118.42481	Title 24 part 6 plan check only.  Build out electrical systems to tenant space for new luxury residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44355	14041-10000-31665	6549 N BUFFALO AVE	91401	2	180B157   537	2329002015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.18975	-118.43029	PV1.  Installation of 3.924 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44356	18041-10000-08258	21901 W SHERMAN WAY	91303	3	183B101    49	2111022012	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.20125	-118.60466	Alterations to a Chase bank- replacing indoor and outdoor luminaires with LED type using existing branch circuitstotal affected area 20012 sq.ftPLAN CHECK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44357	11041-10000-21790	3680 W WILSHIRE BLVD Ste #211	90010	10	132B193    65	5093006028	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.06149	-118.30603	Change of use from Retail to Dental Office.  Full Plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44358	16041-10000-01362	850 S GRAMERCY PL	90005	4	132B193   776	5092025019	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			01/19/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	11/03/2022 12:00:00 AM	ADDRESS	34.05648	-118.31308	(N) 18 UNIT APARTMENT BUILDING WITH SUBTERENEAN GARAGE. 1200 MSA, FIRE ALARM VARIANCE WAS SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44359	14041-20004-29874	12860 W RIVERSIDE DR	91604	4	168B161   422	2357033021	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			PC Info Complete	01/27/2016 12:00:00 AM	PIN	34.15733931	-118.41348969	"01/21/2016 Changes to an approved set of plans. All changes have been clouded and marked Delta 3. Changes include adding new outdoor lighting. Plan check for power and energy.10/01/2015 Changes to an approved set of plans. Load on Panel ""CW"" is no longer future and is now part of the scope of work for this project. Service loads calculations have been updated to reflect the updated Panel ""CW"" load.07/14/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 2. Changes include the relocation of Distribution Panel ""DP"".*****Previous Work Description*****Plan check for power only. Adding new car wash to existing gas station -> Upgrading service to 800A, installing new distribution equipment, and reconnecting existing equipment. Applicant had a precalculated check, verify/change/adjust fees on final.ting equipment. Applicant had a precalculated check, verify/change/adjust fees on final."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44360	16041-20000-05612	3834 W GLENFELIZ BLVD	90039	13	156A207   393	5435033017	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Expired	03/21/2018 12:00:00 AM	ADDRESS	34.12037	-118.26634	Plan check for PV roof mounted system. system size: 8.0kW with 24 modules and 1 inverter (8.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44361	18041-30000-37463	601 S FIGUEROA ST 47TH FLR.	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for T24 only, on (E) office spaces 47th floor. Total area 15,200sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44362	19041-10000-18395	2208 S DUXBURY CIR	90034	5	126B165   295	4309014005	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Issued	06/07/2019 12:00:00 AM	ADDRESS	34.04332	-118.39625	[EPLAN]PLAN CHEKC FOR ROOF MOUNTED 13.76 KVA PV SYSTEM CONSISTING OF 47AC MODULES(SPR-X22-370-D-AC) CONNECTED TO AN EXISTING 400A MAIN PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44363	13041-10000-24817	8739 N AZUL DR	91304	12	195A091    91	2017004019	RE40-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.22884	-118.64898	PV1. ROOFMOUNTED SOLAR ARRAY. TRANSFORMERLESS. SYSTEM SIZE: 11.5 KW. 46 MODULES. 1 STORY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44364	12041-10000-04941	143 S LA BREA AVE	90036	5	138B181  1040	5513019009	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.07233	-118.34423	T.I. to an existing restaurant.  Lighting change, new circuits and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44365	18041-10000-01137	6510 E ELGIN ST	90042	14	154-5A233 192	5493019015	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			Corrections Issued	01/11/2018 12:00:00 AM	ADDRESS	34.1175	-118.17785	NEW ROOFMOUNTED SOLAR SYSTEM, CONSIST OF 13 MODULES (HYUNDAI SOLAR 290W), OPTIMIZERS (SOLAREDGE POWER OPTIMIZER P320 ) WITH A CENTRAL INVERTER (SOLAREDGE SINGLE PHASE INVERTER SE3800H-US). SYSTEM SIZE IS 3.77KWdc AND 3.8KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44366	18041-10000-07929	6300 N VAN NUYS BLVD	91401	12	204B133   312	2694001039	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.18479	-118.44848	"Plan check for T24 only, ""Energy Reduction Project"" for Chase Bank. Replace indoor and outdoor luminaires to LED fixtures using existing circuits. Total area: 13,432 sq.ft indoor + 23,294 sq.ft outdoor"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44367	17041-10001-15761	3344 S LA CIENEGA BLVD	90016	10	120B173   249	5048016026	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM			Corrections Issued	10/24/2017 12:00:00 AM	ADDRESS	34.02695	-118.37186	PC for changes made to lighting and egress lighting. All changes clouded under delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44368	17041-20000-46456	5657 W CENTURY BLVD	90045	11	090B169    20	4125025040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	33.94571	-118.38094	Plan check for energy only. 483 sqft addition and TI to (E) office space in parking garage. New lighting (incl. emergency) - 1,395sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44369	14041-20000-32346	425 S BROADWAY	90013	14	129A211    35	5149025001	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Info Complete	01/16/2015 12:00:00 AM	ADDRESS	34.049	-118.25009	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING. ADDING NEW LIGHTING. ADDING NEW PANELS. LOAD LESS THAN 50 kVA. PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY. TOTAL SQFT 3835.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44370	17041-20001-23799	9137 N COLLETT AVE	91343	12	198B141   626	2671023005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.23692	-118.48412	expeditepv1install roof mounted pv system sized 5.1kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44371	12041-20000-25200	851 W DOWNEY WAY 3rd floor	90089	8	118-5A201  14	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.02004	-118.28659	Change to lighting and replacement of 3 subpanels with like.  Load is less than 400 amps per applicant.  Scope of work is the 3rd floor of an existing low-rise office building.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44372	14041-20000-22946	16629 W CALAHAN ST	91343	12	198B137   853	2687025017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.23675	-118.49478	PV1.  Install 5.355 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44373	18041-20000-34616	865 S FIGUEROA ST SUITE 2300	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for Title 24 Energy only in existing office space high-rise building on 23rd floor. Total area: 4403 sq ft.B#18016-10000-25231	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44374	18041-10000-08608	8728 N WOODMAN AVE	91331	6	195B153   911	2640018021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.22862	-118.43484	REPLACE OUTDOOR EXISTING FIXTURE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44375	16041-10000-33348	1150 S OLIVE ST SUITE 1300	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	PC FOR T24 ENERGY ONLY. PROVIDING NEW LIGHTING IN OFFICE SPACES. tOTAL AFFECTED AREA IS 3300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44376	18041-20000-37575	22600 W ERWIN ST	91367	3	177B097   314	2039018028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.18256	-118.61913	Plan check for a PV1 roof-mounted PV system. System size is 15.4 kWac and consists of (2) inverters, (36) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44377	16041-10000-08759	2231 W 28TH ST	90018	10	123B189   985	5052018026	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Expired	04/13/2018 12:00:00 AM	ADDRESS	34.03004	-118.31576	PV1, rooftop solar installation 6kW    (20) SPR-E20-327    (1)SB6000-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44378	17041-10000-12418	1050 N WESTERN AVE	90732	15	021B193   140	7445010222	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	33.75276	-118.30864	Plan check for T-24 only, install new starbucks inside Ralph market. Install new lightings and new panel < 200A load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44379	18041-20001-06910	19817 W RINALDI ST	91326	12	213B113   308	2701040043	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	PIN	34.2768008	-118.56487771	9/11/2018changes to an approved set of plans.  changes noted delta 2.  changes to relocate loads on existing panels.  thisis plan check only.((((Full plan check for Tenant Improvement of an existing commercial retail building. Reusing multiple existing panels with new circuits and new additonal load > 400A, install (1) new panel, new lighting and new receptacle. Total area: 43,160 sq.ft))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44380	13041-20001-32355	7951 N LARAMIE AVE	91306	3	189B113   537	2107019087	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	11/23/2013 12:00:00 AM	ADDRESS	34.21523	-118.5731	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 3 STRINGS. 20 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44381	12041-10000-10366	8500 W BEVERLY BLVD #736D	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) 754 S.F. REMOTE STORAGE SPACE FOR TENANT SPACE #711;  WORK TO INCLUDE (N) NON-STRUCTURAL WALLS, (N) CEILING/CEILING FIXTURES, (N) INTERIOR FINISHES, (N) EXIT DOOR, (N) MOBILE STORAGE RACKSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44382	17041-10003-12599	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Issued	08/17/2018 12:00:00 AM	ADDRESS	34.02557	-118.3665	"CHANGES TO APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 10 & 11. CHANGES INCLUDE REVISING SERVICE DISTRIBUTION BOARD ON SINGLE LINE DIAGRAM, REVISING ELEVATIONS, ADDING HEAT PUMPS, ADDING TWO PANELBOARDS ""LA1"" & ""LA"", RELOCATING LOADS ON PANEL SCHEDULES, REVISING POWER/LIGHTING FLOOR PLANS, AND REVISING TITLE 24 CALCULATIONS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44383	12041-10001-18772	8600 S CENTRAL AVE	90002	9	097-5A209 289	6043001027	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM			PC Approved	09/26/2012 12:00:00 AM	ADDRESS	33.95988	-118.25616	plan check fopr T24 only office space of about 600 sqfeet.  permit is existing under 12041-70000-18772	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44384	16041-30000-25354	6200 W WILSHIRE BLVD #1004	90048	5	135B177   512	5088015021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.06295	-118.36347	Plan check for Title 24 only. Project site is a suite on the 10th floor of an existing commercial high-rise building. Project scope is a tenant improvement. No work is being done in patient care areas. Total lighting area = 1,180 sq. ft.Note: Building application has been generated under 16016-10000-13806	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44385	14041-10000-14719	753 N LILLIAN WAY	90038	13	141B185   304	5533032023	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			06/03/2014 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Closed	01/19/2018 12:00:00 AM	ADDRESS	34.08495	-118.32792	PLANCHECK FOR POWER AND ENERGY FOR NEW 8 UNIT APARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44386	18041-10000-47258	11911 W SAN VICENTE BLVD STE 124	90049	11	129B145    82	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.05295	-118.47002	T24 PLAN CHECK FOR EXISTING COMMERCIAL BUILDING, ENERGY ONLY, TOTAL SQUARE FOOTAGE = 4,007SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44387	14041-10000-11040	3303 W BERKELEY AVE	90026	13	144A205   179	5425001001	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.08954	-118.27319	PV1, INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(13) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44388	18041-10000-08619	210 E OLYMPIC BLVD	90015	14	126A209   169	5145020052	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.03913	-118.25565	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44389	19041-20001-06863	8700 S PERSHING DR	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Expedited plan check fee.PV2.  Install 70.2 kW DC / 63.0 kW AC roof mounted grid tied PV system.  (195) modules with (2) 33.3 kW rated string inverter.System 3 of 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44390	13041-20000-28997	2000 N ALTA ST PV1	90031	1	136-5A225 198	5211008001	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.06823	-118.20379	New 5kw rooftop mounted PV system for an existing single family dwelling.  System uses Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44391	13041-10001-24732	241 S CORONADO ST	90057	13	136-5A203 299	5155025022	R3-1	Central	Westlake	Greater Echo Park Elysian	YES	2086.20	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.06702	-118.27739	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44392	17041-10000-32537	10010 N REMMET AVE	91311	12	204B105   820	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.25239	-118.60035	PC for T24 only for removal of HID fixtures and replacewith new LED fixtures. Total of 25725sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44393	16041-10001-29129	3959 S BRIGHTON AVE	90062	8	117B193  1732	5036017016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM	ADDRESS	34.01292	-118.30139	PC FOR T24 FOR REPLACEMENT LIGHITNG. ENERGY ONLY. this is plan check only. permit already issued under master application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44394	17041-10003-44218	1650 S WESTMORELAND BLVD	90006	10	126B193   367	5074018004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	34.04303	-118.30641	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDING 50A MAIN BREAKER TO LOAD CENTER, AND CHANGING FEEDER SIZE FEEDING LOAD CENTER.  PC FOR ROOFMOUNTED PV ON SFD WITH ESS SYSTEM INSTALLED (UNDER SUPP. APPLICATION).SYSTEM SIZE 3.0KWAC ADN 4.4KWDC SCOPE INCLUDES 11 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44395	16041-10000-43801	12746 W JEFFERSON BLVD 1-3	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	33.97756	-118.41709	FULL PC FOR POWER AND ENERGY. PROJECT FOR PLAYA VISTA PHYSICIAN OFFICES AND URGENT CARE, CONSIST OF INTERIOR TI ON 3 LEVELS OF AN EXISTING 4-STORY BLDG. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 28013 SQ. FT. B#16016-10000-29918	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44396	11041-20000-19865	1100 S GLENDON AVE 8th floor	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM			PC Approved	09/19/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	T.I.  Remodel of light fixtures on the 8th floor.  Work to be done does not include the private offices.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44397	15041-20000-21245	15211 W FRED WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.20917	-118.46453	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6 KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44398	17041-10000-20175	1875 S CENTURY PARK EAST #1230	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.06115	-118.41457	OFFICE TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44399	19041-10000-02229	923 W BLOOM WALK #308	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.0202	-118.28926	PC T-24 ONLY FOR A TENANT IMPROVEMENT(LAB). TOTAL AREA: 465SQ-FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44400	18041-10000-01381	710 S SANTA FE AVE Back-House	90021	14	124-5A217 282	5166002018	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	ADDRESS	34.03414	-118.22981	Full plan check for a (1) story building change of use from storage to a service building  for a motel/restaurant. Main power being fed from the front house.Note. this is one of the two applications with the same plan under same address.bld: 17016-10000-25795	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44401	19041-30000-11183	12746 W JEFFERSON BLVD Suite 3100-3150	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	03/13/2023 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check for power only. Project site is tenant space is an existing commercial building. Project scope is landlord improvements/work to the space. First time tenant improvement shall be under a separate permit.Note: Building application has been generated under 19016-30000-08635. Electrical core and shell has been finaled under 12041-10000-30785.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44402	14041-20000-22481	10801 N MELVIN AVE	91326	12	207B117   123	2708011003	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Expired	09/19/2016 12:00:00 AM	ADDRESS	34.26639	-118.56034	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.2kW(1) ABB PVI-5.0-OUTD-US-Z-A  transformerless inverter(23) Kyocera #KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44403	18041-10000-19436	2330 E FERNLEAF ST	90031	13	144A217   269	5445024007	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.08812	-118.231	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 16 MODULES (CANADIAN SOLAR CS6K-275P), 16 POWER OPTIMIZERS (SOLAE EDGE P320) AND CENTRAL INVERTER (SOLAR EDGE SE3800H) SYSTEM SIZE IS 4.4KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44404	11041-10000-26697	10119 N PINEWOOD AVE	91042	2	204B201   963	2565014***	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			12/14/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.25288	-118.28612	PLAN CHECK FOR REPLACE EXISTING FACP/ANNUNCIATOR. ALL OTHER FIRE ALARM DEVICES ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44405	18041-10001-04654	1123 W 56TH ST	90037	9	108B197   524	5002025010	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	ADDRESS	33.99151	-118.29459	Supplemental PC for changes to solar panels, inverter and AC disconnect locations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44406	16041-10000-09974	9504 S GRAHAM AVE	90002	15	093A213    37	6048026002	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Expired	04/23/2018 12:00:00 AM	ADDRESS	33.95043	-118.24288	PV1, rooftop solar installation 3 kW AC.      (8) KD255GX-LFB3     (1) SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44407	19041-20000-52832	6112 W WARNER DR	90048	5	132B177    36	5088003041	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.06194	-118.36262	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 3.74 KW DC/3.8 KW AC. SCOPE OF WORK CONSISTS OF (11) PV MODULES WITH OPTIMIZERS AND A 3.8 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44408	15041-20000-40116	6801 N RESEDA BLVD	91335	3	183B125  1000	2126022012	[Q]C2-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.19414	-118.53625	TI to existing commercial building (addition of storage area in the back of an existing gas station). Plan check for energy only. Adding new lighting onto existing circuit. Total sqft. 125.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44409	18041-30000-20180	1440 W 25TH ST	90732	15	009B193    66	7460004013	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	Yes	2973.00	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	33.72207	-118.31119	Full plan check for a commercial, Vons grocery store TI. Scope include new lighting and equipment.Total modify load is more than 400Ampes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44410	17041-10000-03068	9430 N DE SOTO AVE	91311	12	198B109    62	2748002062	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.24198	-118.58834	PC for indoor/outdoor Title 24. Removing HID fixtures and replacing them with new LED ones. Area: 15,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44411	17041-20000-07918	7296 W MANCHESTER AVE	90045	11	096B157   625	4119026044	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	33.95952	-118.42188	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT.  CONVERSION OF 3 RETAIL SPACES TO OFFICE SPACE VOCON.  2960 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44412	18041-10000-28592	5901 W CENTURY BLVD 600	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Issued	07/30/2018 12:00:00 AM	ADDRESS	33.94572	-118.38685	Energy plan check for an office T.I located on the 6th floor of a high rise building. Scope includes new lighting and equipment with a total area of 3,151 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44413	11041-10000-07818	520 S VIRGIL AVE #307	90020	4	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	05/19/2011 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.06457	-118.28687	TI, CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE, PER BUILDING PERMIT.  FULL PLAN CHECK, WITH T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44414	14041-10000-09657	1848 E 57TH ST	90058	9	108B213   498	5105024003	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	33.99112	-118.23941	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.For autoshop (NON-HAZARDOUS PER APPLICANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44415	18041-20001-01538	7805 N BELLAIRE AVE	91605	2	189B161   852	2305038030	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM			PC in Progress	01/20/2018 12:00:00 AM	ADDRESS	34.21228	-118.41121	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44416	15041-20001-08546	18248 W STRATHERN ST	91335	12	189B125   941	2102014044	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.21547	-118.53115	EXPEDITE PER APPLICANT REQUEST.[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 12kW (6+6). Ungrounded system.  (40) 327W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44417	17041-20000-45171	19600 W PLUMMER ST #400	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.2426	-118.5602	PLANCHECK FOR T24 ENERGY. CONVERT (E) RETAIL TO (N) BANK (2421 SF). BUILDING PERMIT # 17016-10000-34865	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44418	19041-10000-25575	100 WORLD WAY 1.5-F/S	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	03/09/2021 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR INSTALLATION OF A NEW ADDRESSABLE FIRE ALARM SYSTEM WITH NEW ADDRESSABLE DEVICES AND EMERGENCY VOICE COMMUNCATION AT TERMINAL 1.5 OF LAX INTERNATIONAL AIRPORT. THE NEW FIRE ALARM SYSTEM IS TYING INTO THE EXISTING TERMINAL 1 FIRE ALARM VIA CLASS A LOOP. FA SYSTEM IN TERMINAL 1.5 OF LAX, SYSTEM INCLUDES 1 FACP AND 1079 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44419	16041-20002-19879	2121 S AVENUE OF THE STARS LOBBY	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM			PC Approved	06/22/2016 12:00:00 AM	ADDRESS	34.05554	-118.41342	06/22/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes include identification of emergency egress luminaires, exit signs and primary daylit zones/sensors.*****Previous Work Description*****Plan check for energy per inspector's corrections notice.  LOBBY LIGHTING RETROFIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44420	17041-10001-10652	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			Corrections Issued	08/28/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC only for a copy of an approved set for restamp. Permit to be pulled under master. 4/7/2016 PC FOR REFEED OF A FEEDER ON 5KV (MEDUIM VOLTAGE),  IN VALERO REFIINERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44421	16041-20000-13225	3531 1/2 E 3RD ST	90063	14	124-5A229 192	5179014021	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.03368	-118.19333	Plan check for a PV1 roof-mounted PV system. System size is 1.7 kWac and consists of (8) modules and (8) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44422	17041-20000-45201	14553 W DELANO ST #317	91411	6	178-5A151 330	2241013038	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.18279	-118.4505	PLANCHECK FOR T24 ENERGY. TEANANT IMPROVEMENT FOR OFFICE. 1339 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44423	15041-20000-08390	19772 W MARIPOSA CREEK WAY	91326	12	213B113   207	2701028023	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.28151	-118.56665	PV1. Install roof mounted PV system in SFD. Interconnected with main service panel. 7 kW AC(26) WS 290 panels(1) 7000 TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44424	16041-10000-29023	5795 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	33.93216	-118.3839	PC FOR TITLE 24. ENERGY ONLY. TOTAL AREA OF 15787 SQ.FT (UNCONDITIONED)INSTALLING NEW LIGHTS (ONLY ON FRACTION OF THE SPACE).REMODEL (E) BATHROOMS ADA COMPLIANT & RAMP MODIFICATION (N) CONVEYER ASSEMBLY & ANCHORAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44425	12041-10000-16495	1455 N BEACHWOOD DR	90028	13	147A189    88	5545013056	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.09743	-118.32141	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE BUILDING T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44426	19041-20001-18059	12125 W VAN NUYS BLVD	91342	7	216B165   216	2531033003	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1042.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	34.28467	-118.39693	08-20-2019 Changes to an approved set of plan PV System , Changes include revised plans according to field conditions. Changes has been clouded. Plan check only.  Fees $0.00 due to california senate bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44427	18041-20000-03337	19344 W CLYMER ST	91326	12	207B117   371	2728006012	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2018 12:00:00 AM	01/29/2018 12:00:00 AM		Issued	01/29/2018 12:00:00 AM	ADDRESS	34.26206	-118.55476	PV1.  Install 8.9 kW DC, 7.6 kW AC roof mounted PV system with battery back-up.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44428	16041-10001-33538	806 E 3RD ST	90013	14	129A215   316	5163015028	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.04564	-118.23594	Change to approved set by modifying the lighting plan, all changes under delta-A only.(((Full plan check. Connect 2 buildings to be just one building. Change of use from residential to live work, and mixed use. (6) live-work space and 7- future commercial space. (1) live-work and (7) commercial space will be under separate permit; However,  all design load is provided. 1600 MS 120/208 3PH 4W. Building is located on Methane Zone.((B# 16016-10000-15325)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44429	14041-20000-32423	1900 S SAWTELLE BLVD	90025	11	126B153   469	4261031023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	03/12/2017 12:00:00 AM	ADDRESS	34.04236	-118.44464	NEW 52 UNIT APARTMENT PLAN CHECK FOR POWER AND ENERGY. 3 LEVELS OF UNDERGROUND PARKING. FIRE ALARM VARIANCE WILL BE FILED ONCE OWNER INFORMATION HAS BEEN MADE AVAILABLE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44430	12041-10000-25695	1034 S CATALINA ST	90006	1	129B197   357	5078012017	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			PC Approved	10/29/2012 12:00:00 AM	ADDRESS	34.05171	-118.29462	Changes to approved plans and change of engineer.  Change to point of connection of PV system and upgrade to 600A service. (Associated App #: 12041-10000-09132 and 12041-10001-09132) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44431	18041-10000-13206	5071 N SAN FERNANDO ROAD WEST	90039	13	162B205     8	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.14413	-118.27114	PC FOR POWER ONLY. SCOPE INCLUDES ADDING A PROCESSING EQUIPMENT FOR A HEALTHCARE FACILITY. REPLACING ONE NEW WATER FOR INJECTION STILL.  NEW CONNECTED LOAD IS GREATER THAN 400A. B#18016-10000-11098	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44432	17041-10001-25603	20541 W KINGSBURY ST	91311	12	207B109   398	2707009028	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.26372	-118.58114	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES CHANGES TO AC MODULES FROM 327W TO 335W NEW TOTAL DC SIDE  RATING 6.7KW.THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44433	19041-10000-18547	615 N RODS WAY	91340	7	216B161    23	2514002085	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.29266	-118.41731	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44434	13041-20000-01008	10420 W SCENARIO LANE	90077	5	151-5A151 766	4380011004	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2013 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.10857	-118.44738	Photovoltaic system on roof of single family dwelling using Enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44435	19041-10000-29650	1371 N EUBANK AVE	90744	15	036B209   611	7422017900	OS-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/05/2020 12:00:00 AM		Permit Finaled	05/11/2021 12:00:00 AM	ADDRESS	33.79125	-118.25641	$0 FINAL FEES PER AB1414PV2. NEW SOLAR SYSTEM SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 31.2KWdc / 22.8KWac.(96)MODULES- JIMKO JKM325PP-72V(2)INVERTERS- PIKA X11402(12)OPTIMIZERS- PIKA PV LINK(2)BATTERIES - PIKA HARBOR 6	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44436	18041-20000-46320	1999 S AVENUE OF THE STARS #1150	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 2 Energy for office T.I. Total area: 2804 sq ft. B#18016-20000-36174	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44437	18041-20001-15505	5555 W MELROSE AVE STAGE 16	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			PC Approved	04/30/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	"04-30-2019 Chages to an approved set of plan, changes include indicate overcurrent protection in panel ""1LDA"" and ""1LDB"" to series rating ETON  KD and BAB at 22KAIC, Plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44438	18041-10000-08371	9122 N ORION AVE	91343	7	198B145   357	2656027067	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	02/23/2021 12:00:00 AM	ADDRESS	34.23623	-118.47182	PC for power and energy for 4 story 14 apartment unit building. Installing new 1000A 120/240V service, panelboards, lighting, receptacles. Inverter UPS and equipment.Total area is 16058sqft. B#15010-30000-01220. Fire Alarm Variance has not been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44439	11041-10000-16669	6707 N BIANCA AVE	91406	6	180B129   182	2229010095	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2011 12:00:00 AM			Corrections Issued	08/11/2011 12:00:00 AM	ADDRESS	34.19237	-118.51323	New roof mounted PV system.  System size is 9.03 KW and using standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44440	17041-10000-06316	970 W 190TH ST STE 860	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	33.85812	-118.29302	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 1465 SQ. FT. B#17016-10000-01730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44441	17041-10001-19628	101 N VIRGIL AVE	90004	13	138B197   763	5501007006	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.07372	-118.28703	Additional T24 plan check for office area that was not covered under the master plan with permit# 17041-10000-19628. Total office area under this scope is 1,260 sq.ft. Additional permit shall be issued for new branch circuit in the office area.       Building permit #17016-10000-06410	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44442	18041-20000-41945	12068 N BEAUFAIT AVE	91326	12	216B125    14	2870004024	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Expired	04/27/2024 12:00:00 AM	ADDRESS	34.29246	-118.53765	PV1.  Install 10.23 kW roof mounted grid tied PV system.  (31) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44443	16041-10000-39327	1728 S 5TH AVE	90019	10	126B189   731	5072022018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Expired	09/08/2023 12:00:00 AM	ADDRESS	34.04094	-118.3223	Installation of new roof mounted solar PV array on existing two family dwelling.  Total system size = 2.0 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44444	13041-10000-30135	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.04842	-118.33486	AT THE MIDTOWN CROSSING SHOPPING MALL, INSTALLATION OF MAIN/METER SECTIONS AND DISTRIBUTION BOARDS FOR ANCHOR STORES-PETSMART;SMART & FINAL; SPORT AUTHORITY.HORIZONTAL 3000A BUS FROM SWBD MSR IS EXTENDED TO METER/MAIN LINE-UP AND FEEDERS ARE FED TO THE DISTRIBUTION BOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44445	14041-20001-06851	10361 N SOPHIA AVE	91344	12	204B137   108	2679024022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.25908	-118.48758	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44446	17041-20001-45171	19600 W PLUMMER ST #400	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	34.2426	-118.5602	1/30/2018first time tenant plan check for power.  energy has been approved under master application.  permit fees paid under 17041-20000-45171.  this is plan check only. (((PLANCHECK FOR T24 ENERGY. CONVERT (E) RETAIL TO (N) BANK (2421 SF). BUILDING PERMIT # 17016-10000-34865)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44447	17041-10000-27928	4954 N VAN NUYS BLVD #200	91403	4	171A151   258	2248007143	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.1608	-118.44849	TI TO MEDICAL OFFICE. PC FOR POWER AND ENERGY FOR WORK DONE IN PATIENT CARE AREAS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44448	19041-30000-23812	411 E ROSE AVE	90291	11	111B141   409	4240007038	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM			PC Info Complete	06/20/2019 12:00:00 AM	ADDRESS	33.99785	-118.47476	PC (T-24 ONLY) FOR TENANT IMPROVEMENT - DIVIDE (E) 500 S.F. STORAGE AREA TO 3 STORAGE SPACES WITH NON-STRUCTURAL INTERIOR PARTITIONS. AREA OF SCOPE 542SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44449	15041-10001-12485	19850 S MAGELLAN DR	90502	15	057B197    56	7351034065	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	33.85035	-118.29277	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 196KW INTERCONNECTED WITH MSP.(734) SUNPOWER SPR-E20-327 MODULES(7) CHINT CPS TRANSFORMERLESS INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44450	19041-10000-07494	10960 W WILSHIRE BLVD 22ND FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.058	-118.44597	PC T/24 FOR OFFICE TI LOCATED ON THE 22ND FLOOR SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH AN AREA OF 2179.58 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44451	13041-10000-32255	8427 W HILLROSE ST	91040	7	207B189   651	2555004028	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.26351	-118.3168	PV1, Install 7.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE6000A-US. 29 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44452	17041-20000-31797	2000 S AVENUE OF THE STARS Stes 410N,-600N, 650N	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for Title 24 only. Project site are suites on (2) floors of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,550 sq. ft.Note: Building applications have been generated under 17016-10000-25514, 16016-10000-28828, and 17016-10000-25467.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44453	16041-20000-37967	15445 W VENTURA BLVD	91403	5	168B145   769	2261039012	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			No Progress	09/24/2018 12:00:00 AM	ADDRESS	34.15467	-118.47025	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is tenant improvement/combination of (4) existing retail spaces into (1) retail space. Total lighting area = 1,877 sq. ft.Note: Building application has been generated under 16016-20000-25709	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44454	18041-20000-29672	11755 W WILSHIRE BLVD 12th flr	90025	11	129B145   683	4265010192	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.04856	-118.46231	ti to an existing commercial high rise building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44455	16041-20001-11716	4540 N NATICK AVE	91403	4	168A149   141	2265001014	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/19/2016 12:00:00 AM	ADDRESS	34.15434	-118.45402	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 25 kWac and consists of (2) inverters, (96) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44456	18041-10000-07771	6200 N VARIEL AVE	91367	3	177B105   132	2149004024	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			03/02/2018 12:00:00 AM			Reviewed by Supervisor	04/11/2018 12:00:00 AM	ADDRESS	34.18341	-118.59258	NEW FIRE ALARM SYSTEM FOR 7-STORY APARTMENT BUILDING, OVER 1 BASEMENT PARKING. (14) PANELS, (683) DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44457	11041-20000-04397	1035 W FIGUEROA TER BLDG 2	90012	1	136-5A213  45	5406022078	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			03/07/2011 12:00:00 AM	03/11/2014 12:00:00 AM		Issued	03/11/2014 12:00:00 AM	ADDRESS	34.06894	-118.24569	PLAN CHECK POWER AND ENERGY FOR NEW 23 UNIT APARTMENT BUILDING.  IN METHANE ZONE. A variance to separate out the fire alarm approval was submitted on December 27, 2011.  The methane component of the scope of work was reviewed and the plan substantially complies with the required methane requirements.Variance to extend the plan check was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44458	17041-10001-38760	4601 S BROADWAY 2ND FL	90037	9	112-5A203 274	5110009001	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	34.00182	-118.27861	changes to lighting system- include patio area as office and chnage some types of luminaires PLAN CHECK ONLY ((((((((INTERIOR REMODELING OF EXISTING OFFICE SPACEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44459	13041-20001-10312	6635 N FALLBROOK AVE	91307	12	180B097   170	2038040005	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.18998	-118.6262	(((CHANGES MADE TO APPROVED SET OF PLANS. ADDED FIXTURE TYPE B7A.)))Full plan check for new Starbucks inside Target.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44460	17041-20000-44992	2418 N VALENTINE ST	90026	13	144B213   215	5443021022	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.0932	-118.24565	INSTALLATION OF TESLA POWERWALL ENERGY STORAGE SYSTEM . 13.5KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44461	13041-20000-33358	4701 S CENTRAL AVE	90011	9	112-5A209 335	5108022001	C2-1VL	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.00066	-118.25673	PC FOR T24 ENERGY ONLY PER APPLICANT REQUEST. NEW LIGHTING. WORK DONE IN COMMUNITY ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44462	15041-20000-18687	6344 N TOPANGA CANYON BLVD A-2020	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	Plan check for power and Title-24 (energy).  Total area = 3,248 sq. ft.  T.I. to commercial first time tenant (Smirnoff Dance Studio).  New lighting and recepticles.  Counter plan check per E.M.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44463	10041-20000-19783	555 W 5TH ST 3rd Floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/28/2010 12:00:00 AM		Permit Finaled	01/05/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I. to existing high rise building in 3rd floor at office area.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44464	17041-20001-10861	12727 W SHERMAN WAY Bldg. A	91605	2	183B161    11	2324004004	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Issued	12/19/2019 12:00:00 AM	ADDRESS	34.20137	-118.41091	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED PLAN. ADDITION OF A 400A PANEL AND A 225 KVA TRANSFORMER, AND CHANGES MADE TO THE SINGLE LINE ARRANGEMENT AND INFORMATION. 3 EQUIPMENT ADDED TO PANEL SCHEDULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44465	15041-10001-08918	454 E COMMERCIAL ST	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			PC Approved	07/08/2016 12:00:00 AM	ADDRESS	34.05313	-118.23621	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<<PV2, INSTALL 80 KW AC ROOF-MOUNTED SOLAR ARAY ON ROOF OF THE PARKING STRUCTURE. TIE WITH MAIN 3000 A SERVICE PANEL. (376) MODULES AND (4) INVERTERS 20KW. ONE PART OF E COMMERCIAL ST PROJECT FOR PUBLIC WORK BLDS.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44466	17041-10004-32818	7348 N ETHEL AVE Units A&B	91605	2	186B161   541	2327015007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Info Complete	01/22/2019 12:00:00 AM	PIN	34.20432132	-118.41768776	Change to approved set by adding a transformer and a panel. One existing panel also being removed. all changes under delta-3 only.(((Supplemental for changes to approved set of plans under delta 2 only - changes include upsizing 2 transformers from 75kva to 150kva and 2 panels from 200A to 400A . Changes also include updating transformers and panels locations and modifying lighting fixture wattage.***original scopePlan check for power and energy. Project site is a new commercial building. Project scope is a first time tenant. Total lighting area = 2,208 sq. ft.Note: Building application has been generated under 16014-20000-04290)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44467	13041-20000-06242	15243 W VANOWEN ST #500	91405	6	183B145   701	2220020019	C1-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	07/17/2013 12:00:00 AM	ADDRESS	34.19406	-118.46504	New panels, new circuits/loads and lighting in a Medical Office inside an existing low-rise building.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44468	13041-10000-09307	818 S BROADWAY #114	90014	14	127-5A209 160	5144016064	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/15/2013 12:00:00 AM	ADDRESS	34.04318	-118.255	RENOVATION OF SMALL RETAIL SPACES FOR JEWELRY STORE. TOTAL AREA 1000 SQ FT. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44469	14041-10000-14819	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	Plan check for lighting.  Total area = 5490 sq. ft.T.I for existing high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44470	19041-10000-19587	20650 W RINALDI ST	91311	12	210B109    41	2707001019	A1-1, [T]RE11-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	05/05/2022 12:00:00 AM		Issued	05/05/2022 12:00:00 AM				PC FOR ENERGY AND POWER FOR NEW PRIVATE STREET OUTDOOR LIGHTS.SCOPE INCLUDES NEW SERVICE(S), CIRUCUITS AND LIGHTS. TOTAL AFFECTED AREA  ABOUT 85700 SQ.FT. Permit to be puled on 10000 and plan check only on 10001. MZ	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44471	16041-10001-23148	9834 W SAN CIR	90210	5	150B157   183	4384021020	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	08/09/2016 12:00:00 AM	ADDRESS	34.10552	-118.42534	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.4KWac.(42)MODULES-LG 365N2W-B3(42)OPTIMIZERS-SOLAREDGE P400W(1)INVERTER-SOLAREDGE SE11400A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44472	17041-10002-04616	20065 W RINALDI ST BLDG A4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Closed	03/16/2021 12:00:00 AM	ADDRESS	34.27548	-118.57184	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 24, 25,28 & 13. CHANGES INCLUDE REMOVING SITE LIGHTING, REPLACING EXTERIOR LIGHTS, AND REVISING PANEL SCHEDULES. ALSO ADDING A NEW 800A DISTRIBUTION, NEW 112.5KVA TRANSFORMER, AND NEW CIRCUITS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44473	12041-10000-26881	19055 W MUIRKIRK DR	91326	12	219B121   132	2820003024	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.29571	-118.54857	New 10.02 kw roof mounted PV for a single family. (PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44474	13041-10000-24705	2436 N GRIFFITH PARK BLVD	90039	4	150A205   371	5432006020	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	34.10382	-118.27199	PV1 1.96KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: SOLAREDGE SE3000A-US] [( 8) MOD: Trina {TSM-245PC05.18} with optimizers]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44475	19041-10000-00760	230 E PACIFIC COAST HWY	90744	15	036B209   767	7422008010	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	33.79106	-118.2609	FULL P.C POWER AND ENERGY FOR NEW 120/208 VAC 3PH 4W 1000A SERVICE, TOTAL SQFT = 6,561. SCOPE OF WORK INCLUDES PANELS, EQUIPMENTS AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44476	16041-10000-02376	2500 S SIGNAL ST BERTH-68	90731	15	018B201   298	7440026903		Harbor				9800.31	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	33.72053	-118.27222	Service upgrade to 120/240VAC, 600 Amp, 1Ph, and replace the existing generator to a new 125KVA and reconnect the existing loads. No New Load Added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44477	16041-10007-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	33.94502	-118.40714	CHANGES TO APPROVED SET UNDER DLETA  ASI-N007.ADDITION OF LIGHTS AND ONE NEW CIRCUIT IN EXISTING OFFICE AREA IN TERMINAL 3 ROOMS F5-31, F5-32 AND F5-32A . UPDATED T-24 FORM TO REFLECT NEW LIGHTING AND EMERGENCY LTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44478	19041-20000-26324	3214 W BEVERLY BLVD	90057	13	138A201   211	5155001018	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Issued	07/15/2019 12:00:00 AM	ADDRESS	34.07232	-118.2837	Plan check for power only 800A  120/240 Volts 4 panels and 1 cicuit. Note: future permit shall be required for work done in tenant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44479	16041-10000-23200	2968 W 6TH ST	90020	10	135A201   140	5077007029	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Closed	06/30/2017 12:00:00 AM	ADDRESS	34.06349	-118.28603	NEW 800 AMP TEMPORARY SERVICE FOR CONSTRUCTION. 800 AMP SWITCH BOARD WITH A MAN LIFT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44480	19041-20000-34468	10989 W BLUFFSIDE DR	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	09/02/2022 12:00:00 AM	ADDRESS	34.14187	-118.36957	PV2 BUILDING #3 (N) 20.4 KW AC/22.68 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (63) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44481	14041-10000-19649	1731 W MIRACOSTA ST	90732	15	018B189   316	7559018002	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	33.74281	-118.31473	SOLAR PV STANDARD PLAN. CENTRAL/STRING INVERTER SYSTEMS FOR 1 AND 2 FAMILY DWELLINGS.  TOTAL # OF INVERTERS INSTALLED: 1. SYSTEM SIZE: 4.59kW. NUMBER OF MODULES: 18. INVERTER OUTPUT POWER RATING: 3600 W	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44482	14041-20000-11794	12140 N BELLANDO CT	91344	12	219B125    92	2601073021	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.29465	-118.52543	((($0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012))PV1Install roof-mounted solar array on SFD. System size: 13.5kW(1) Power-One #Aurora PVI-4.2-OUTD-S-US-Z-A transformerless inverter(1) Power-One #Aurora PVI-6000-OUTD-US-Z-A transformerless inverter(54) Canadian Solar #CS6P-250PX pv modules(2) load centers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44483	14041-20001-06762	19100 W OLYMPIA ST	91326	12	207B121   385	2728002025	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.26463	-118.54982	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44484	13041-20000-33864	10618 N MELVIN AVE	91326	12	207B117   322	2708005005	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.26301	-118.55991	PV1 TRANFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC. 36 MODULES AND 2 INVERTERS. SUBMITTED PER APPLICANT REQUEST.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44485	15041-10000-30692	4200 N LATONA AVE	90031	1	144A225   118	5207014020	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	ADDRESS	34.09011	-118.20305	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 2.5KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-90000-28901.  THIS IS PLAN CHECK ONLY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44486	12041-20000-07082	12201 W PICO BLVD	90064	11	123B149  1104	4259029013	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.02898	-118.45147	TI for a sliding door company (retail). T-24 Plan Check for Energy and Emergency Lighting. 1200 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44487	15041-10000-26355	1660 W ANAHEIM ST Tank-farm-Blk 67	90744	15	030B201   315	7412022010	OS-1XL, [Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	PIN	33.77820981	-118.28313647	Power plan check for a (2) circuits (one from normal and one from UPS) to a chopper valve control panel located in a harzadous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44488	19041-20001-52437	315 S 4TH AVE	90291	11	111B141   532	4286006034	[T][Q]CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	02/11/2021 12:00:00 AM	ADDRESS	33.99712	-118.4749	Expedited plan check fee.PV3.  Install 239.2 kW roof mounted PV system.  (598) modules with (2) 33.3 kW and (6) 20 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44489	18041-10000-24607	2405 E POMEROY AVE	90033	14	132A225   557	5177006015	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2032.00	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	07/26/2023 12:00:00 AM	ADDRESS	34.05366	-118.203	Full plan check for a new 4-story hotel with 81-guest rooms over the ground floor of restaurant/lobby, parking and garage. Scoepe including a 2500A 120/208V 3-phase servcie. Building application: 16010-10000-02005	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44490	13041-10000-09397	525 S FLOWER ST FLRS 1-3	90071	9	130-5A209 146	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Issued	04/11/2013 12:00:00 AM	ADDRESS	34.05109	-118.25696	IN EXISTING CONFERENCE ROOMS AND OPEN OFFICES ON 1ST THROUGH FLOORS, ADDING NEW LUMINAIRES ON EXISTING BRANCH CIRCUITS. EMERGENCY LUMINAIRES REMAINED THE SAME.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44491	16041-20000-30646	10842 W MAGNOLIA BLVD	91601	2	171B173   641	2419008056	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.16477	-118.36729	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 18,088 sq. ft.Note: Building application has been generated under 16016-10000-18502	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44492	18041-20000-10375	20662 W WALNUT CIR	91326	12	219B109   358	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29426	-118.58438	PV1.  Install 3.84 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44493	13041-10001-27871	20858 W COLLINS ST	91367	3	174B109   357	2149015017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.17333	-118.58734	EXPEDITED PER APPLICANTS REQUESTPV1 7.5KWdc. 240V. negative GND. std PLAN. 1story. Roofmount. [(1) inverters: {Fronius IG PLUS V 7.5-1UNI}]. [(30)modules: {Trina {TSM-250PA05.08}}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44494	19041-10000-18490	8201-8203 W 3RD ST	90048	5	138B173   840	5511019036	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM			PC Info Complete	12/27/2019 12:00:00 AM	ADDRESS	34.07259	-118.36814	FULL PC POWER AND ENERGY. PROPOSED NEW 1 STORY RESTAURANT W/ROOF DECK OUTDOOR DINING AREA . SERVICE IS 400A ,120/208V, 3PH,4W. SCOPE OF WORK AREA IS 935SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44495	16041-10000-41236	1000 S GRAND AVE	90015	14	127-5A209 242	5139009008	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	ADDRESS	34.04258	-118.26079	PC for energy only to an existing 7 story mixed used building. Adding new lighting to corridor. Total sqft = 1355.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44496	15041-20001-42469	4600 N VANALDEN AVE	91356	3	168B117   538	2177003001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.15362	-118.55422	VOID.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.5KWac/ 8.4KWdc. (30)MODULES-SOLARWORLD 280 MONO BLACK(30)MICROINVERTERS-ENPHASE M250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44497	19041-10000-29712	12925 N BRADLEY AVE	91342	7	222B145   472	2506003017	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.30432	-118.45895	Replace fluorescent troffers with new LED retrofit kits -  Indoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44498	16041-20000-33711	5159 N COSTELLO AVE	91423	4	171B153   527	2269008006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.16425	-118.43839	PV1.  Install 13.08 kW grid tied photovoltaic system.  (40) SunPower AC modules with 100A solar load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44499	13041-10001-32172	3525 W 3RD ST # 4	90004	10	135B197   146	5518030021	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	PIN	34.06930274	-118.29253852	PLANCHECK ONLY. T24 ONLY CHANGES TO PREVIOUSLY APPROVED PLANCHECK UNDER 13041-10000-32172. PERMIT WILL BE UNDER 13041-10000-32172 ALSO.TI and change of use from beauty parlor to take out restaurant(1152 s.f)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44500	13041-10000-20638	2917 E 1ST ST	90033	14	126A225    32	5180020031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.04084	-118.20294	New roof mounted PV system with 34.56 KWdc on a 4 story commercial building.  3 10KW FRONIUS INVERTERS. 144 MODULES Q CELL. 6 COMBINER BOX.  1 SUBPANEL. EXISTING 1200 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44501	17041-10000-31487	2029 S CENTURY PARK EAST 1260	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TITLE 24 PLAN CHECK FOR - NON STRUCTURAL OFFICE TI PORTION OF 12TH FLOOR:  partitions, suspended ceiling, and finishes. - TOTAL AFFECTED AREA = 3675 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44502	12041-20001-00486	16026 W RAYEN ST	91343	12	195B141   365	2672019019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	03/13/2012 12:00:00 AM	ADDRESS	34.23188	-118.48159	revision by inspection add moniter system one ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44503	12041-10000-25067	11755 W WILSHIRE BLVD #2150	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM			PC Approved	10/22/2012 12:00:00 AM	PIN	34.04869377	-118.46238681	TI in an existing office. EPC is for T24 and emergency lights. (21st floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44504	11041-10000-18240	4002 S LINCOLN BLVD	90292	11	108B149  1165	4230002002	[Q]C2-1-CDO, [Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	33.99031	-118.44734	TI TO AN EXISTING 7-ELEVEN.  REPLACEMENT OF EXISTING LIGHT FIXTURES WITH LED FIXTURES.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44505	18041-10000-04603	444 S FLOWER ST # 1550	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.05189	-118.25546	INTERIOR IMPROVEMENT IN OFFICES ON THE 15TH FLOORPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44506	15041-20000-33444	10915 W VENICE BLVD	90034	5	117B161   863	4252020040	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Info Complete	10/08/2015 12:00:00 AM	ADDRESS	34.01597	-118.41242	T-24, PC FOR ENERGY ONLY. TI on at (E) commercial building (Shell and Core only) for a mattress shop. Change of use from retail/auto repair to retail | Restripe parking lot to provide required parkings to accommodate the proposed change of use at subject building and (E) dental office building on site. Scope includes new lighting. total area is 7092 sq. ft.Permit pulled under #15041-30000-37972	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44507	13041-10000-32275	758 E 107TH ST	90002	8	090A207   403	6051023034	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	33.93913	-118.26101	PV1, Install 3.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 15 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44508	17041-10001-44658	1025 S STANFORD AVE	90021	14	124-5A211 328	5132009019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.03336	-118.24926	DELTA 1 CHANGES TO AN APPROVED SET. CHANGES TO ANNUNCIATOR SCHEDULE, OFFICE SPACES DEVICE LAYOUT AND PS CALCULATIONS. SCOPE ALSO INCLUDES ADDITION OF 2 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44509	19041-10000-49448	1157 W 14TH ST	90731	15	012B193   200	7458022012	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	33.73144	-118.30247	NOTE: PERMIT FEE IS $0 DUE TO AB 1414. [EPLAN]  Changes to an  approved set. Changes include relocation of equipment. Original Application No: 19041-10000-32502**INSPECTOR TO VERIFY MOUNTING HEIGHT OF EQUIPMENT AND IF IT REQUIRES PHYSICAL PROTECTION FROM VEHICULAR MOVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44510	11041-10000-20634	1521-1533 S PENMAR AVE BLDG 28	90291	11	111B149   146	4243001041	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.0037	-118.45825	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44511	12041-10000-17344	189 S THE GROVE DR L-5	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Approved	10/05/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	T.I. to an existing retail space.  Load is less than 400Amps.  New lighting.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44512	19041-10002-01689	6340 W DREXEL AVE	90048	5	135B177   148	5510009026	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.06863	-118.36588	SUPPLEMENTAL FOR EXPEDITE FEEPC FOR ROOF MOUNTED 11.4 KVA PV SYSTEM. SYSTEM CONSITS OF 2 CENTRAL INVERTERS(SE3000H-US & SE7600H-US) WITH 35 MODULES USING P400 OPTIMIZERS  INCLUDING  2 ENERGY STORAGE SYSTEMS LG 9G CHEM 9.8KWH. 1 LOAD CENTER, AND AUTO TRANSFORMER, WITH RELOCATION OF LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44513	19041-20000-18579	1457 N VAN NESS AVE 2,3,5TH-FLR	90028	13	147A191   102	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM			PC Info Complete	05/16/2019 12:00:00 AM	ADDRESS	34.09731	-118.31598	Plan check for Title 24 only in existing space T.I. Partial 2nd, 3rd and  5th Floor, circuits existing to remain. Total area: 3900 sq ft. B#18016-10000-39976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44514	19041-20000-48885	6345 N BALBOA BLVD BLDG 3	91406	6	180B133   572	2230024***	[Q]C4-1VL-RIO	South Valley	Reseda - West Van Nuys	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.1861	-118.50323	Existing commercial lobby renovation (indoor/outdoor).  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44515	13041-10000-16603	6351 N OWENSMOUTH AVE	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	34.18594	-118.60181	TI for office space on first floor of a 2-story building, 1100 sq ft.  Energy plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44516	15041-20000-17993	9301 N TAMPA AVE 3rd Floor	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is part of the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,213.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44517	19041-10001-05054	1577 W FAIR PARK AVE	90041	14	160-5A227 212	5689025019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Expired	11/08/2023 12:00:00 AM	ADDRESS	34.13394	-118.20059	Change to approved set by adding optimizer on the floor plan. Back feed connection is under line side tap. Inspection verify with Utility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44518	10041-10000-01971	10201 W PICO BLVD	90035	5	129B161  1442	4315019012	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			02/04/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check power and energy for new load (IT equipment, UPS, and PDU).  Existing to service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44519	15041-10001-09642	15474 W DUOMO VIA	90077	5	156B145   197	4378036019	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	ADDRESS	34.12386	-118.47023	Expedite per customer request(((PV1 9.03KW roof-mounted  microinverter system with (42) SW-270 Mono solar modules, (42) Enphse M215 interconnecting through a new load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44520	18041-10000-38413	700 N SPAULDING AVE	90046	5	141B177   554	5527007024	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Apartment			10/09/2018 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	08/31/2021 12:00:00 AM	ADDRESS	34.08411	-118.35721	***NEW 3-STORY MIXED USE COMMERCIAL AND RESIDENTIAL BLDG WITH TWO SUBTERRANEAN LEVELS AND ROOF DECKS. 22 MARKET RATE UNITS AND 2 EXTREMELY LOW INCOME UNITS PER TOC TIER 2.*** building permit #18010-10000-03330NEW MULTI FAMILY 3 STORY BUILDING WITH 24 UNITS, 2500A SERVICE, 557 DEVICES, ELEVATORS.**plan checker to verify fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44521	12041-10000-07344	1930 W WILSHIRE BLVD 10TH FLR	90057	1	132A203    41	5142002019	C4-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.05713	-118.27464	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING. CONVERT  EXISTING OFFICE INTO VIDEO RECORDING STUDIO/OFFICE ON 10TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44522	11041-10000-22291	110 S BARRINGTON AVE	90049	11	135B145   573	4401006020	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	01/04/2012 12:00:00 AM	ADDRESS	34.06502	-118.46967	New fire alarm system for a modular building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44523	16041-10000-43230	420 E 3RD ST #107	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.04686	-118.24182	Plan check for Title 24 only in existing space convert from retail to tak out coffee shop T.I. This plan shall  cover the stroage space for the coffee shop. Total area: 396 sq ft.B#16041-10000-10251	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44524	16041-20000-04880	8623 N BURNET AVE	91343	6	192B145     7	2654041***	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Apartment			02/11/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Expired	03/23/2018 12:00:00 AM	ADDRESS	34.22692	-118.46345	Plan check for a PV2 roof-mounted PV system. PV system is for Unit 1 of a 6-unit apartment building. System size is 3 kWac and consists of (1) inverter, (6) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44525	14041-20011-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/08/2019 12:00:00 AM			PC Approved	03/11/2019 12:00:00 AM	ADDRESS	33.95713	-118.3847	03-08-2019 Changes to an approved set of plan, changes include replace (11) L1E fixtures with (22) L14 fixtures in the same location in te 1st floor cortyard. No load change. Plan check only, changes apply to clouded area delta 17 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44526	13041-10001-35778	475 S 26TH ST	90049	11	126B137    37	4264004013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	PIN	34.04462271	-118.48702462	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON STD PLAN. MICROINVERTER. SYSTEM SIZE: 9KW DC.( 36) SOLARWORLD SW 250 MODULES(36) ENHPHASE M215 MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44527	16041-10000-24790	13536 W BEAVER ST	91342	7	225B157   574	2510020018	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Expired	04/07/2024 12:00:00 AM	ADDRESS	34.3126	-118.42749	FEES ARE $0 DUE TO SENATE BILL 1222. PV1. NEW SOLAR SYSTME ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.0KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44528	17041-20001-35695	2275 N HIDALGO AVE	90039	13	147A209   201	5440006024	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	PIN	34.09715131	-118.25719039	expeditepv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44529	18041-20000-24346	3601 S TROUSDALE PKWY 3rd Floor	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.02017	-118.28558	Tenant improvement to expand lounge area.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44530	16041-20001-27025	9201 N CRANFORD AVE	91331	6	198B161   366	2629027904	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.2366	-118.41261	"New plans for tenant space restroom loads.  Modified transformer rating and wiring details.  Supplemental permit address modified to 9201 Cranford for HP release.  (((New 2-story commercial building core and shell.  Plan check for power and energy.  service equipment only ""MSA"" all tenant panels and circuits to be future under seperate permit.  outdoor Title 24 only.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44531	15041-10001-19761	3554 S MOUNTAIN VIEW AVE	90066	11	114B153   261	4248022029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.01106	-118.4341	((EXPEDITED PC PER APPLICANT REQ.))PV.1 ROOF MTD., 7.5 KW DC, 30 PANELS, 30 MICROINVERTERS, NEW 125 SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44532	14041-10001-10196	127 S ANITA AVE	90049	11	132B141   648	4405028006	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.05654	-118.48335	Expedited RSES plan check per applicant request.{{ Install 6.25 kW DC roof-mounted solar array on a two-story house, interconnect with  main service panel. (1)Transformerless inverter: POWER-ONE # AURORA PV1-4.2-OUTD-S-US-Z-A(25) Modules: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44533	11041-10000-15546	841 S LA PALOMA AVE	90744	15	024B205    22	7440014904	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	33.76076	-118.26497	REPLACEMENT OF 3 MOTOR CONTROL CENTERS IN A CLASSIFIED AREA.  PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44534	19041-20000-22072	7590 N GLENOAKS BLVD 2nd Floor	91504	2	186B181    61	2401042012	(Q)C1.5-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.20894	-118.34376	Remodel of (E) 2nd story restrooms.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44535	14041-20000-30538	14027 N CLAYWOOD AVE	91342	7	231B157   204	2582018006	RS-1	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.32752	-118.42689	PV1 MICROINVERTER STANDARD PLAN SIZED 8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44536	14041-10000-30600	4201 W WILSHIRE BLVD 1st floor	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Expired	12/01/2016 12:00:00 AM	ADDRESS	34.06189	-118.31911	TI to 1st floor interior corridor of (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44537	15041-10000-38183	307 W 4TH ST	90013	14	130-5A211 156	5149015023	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Expired	12/22/2017 12:00:00 AM	ADDRESS	34.04986	-118.24968	INSTALLING NEW FA SYSTEM FOR A 3-STORY COMMERCIAL BUILDING, JUST FOR BASEMENT & 1ST FLOOR. WITH 60 DEVICES AND CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44538	16041-10000-11587	833 W 6TH ST	90731	15	015B197   346	7451034010	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Issued	05/12/2016 12:00:00 AM	ADDRESS	33.73867	-118.29532	PV1, INSTALL NEW 2.805 KW DC ROOF-MOUNTED SOLAR ARRAY ON ASINGLE FAMILY HOME.(11) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44539	15041-20000-30507	6719 N RUDNICK AVE	91303	3	180B101   136	2139009039	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.19244	-118.61258	Plan check for a PV1 roof-mounted PV system. System size is 6 kWAC and consists of (1) inverter, (26) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44540	17041-10000-41334	10611 W PICO BLVD	90064	5	126B157   405	4320012036	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			PC Info Complete	11/15/2017 12:00:00 AM	ADDRESS	34.04341	-118.42244	PC FOR (E) RESAURANT TI (MCDONALDS) FOR TITLE 24 ENERGY ONLY. SOCPE INCLUDES NEW PANEL CIRCUITS EQUIPMENT AND LIGHTS. TOTAL 2892 INDOOR AND 3600 OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44541	12041-20000-12486	2681 N GLENDOWER AVE	90027	4	153B197    86	5588020018	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.11658	-118.29381	solar system on single family dwelling, using enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44542	19041-20000-37079	11211 N SEPULVEDA BLVD lot #22	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 4.09 KW DC ROOF MOUNTED PV SYSTEM WITH (13) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44543	15041-20000-11890	6351 N OWENSMOUTH AVE	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			Corrections Issued	04/30/2015 12:00:00 AM	ADDRESS	34.18594	-118.60181	"REPLACEMENT OF EXISTING SWITCHGEAR TO HANDLE NEW AIC RATINGS. THIS BUILDING IS TRANSFERING ITS SOURCE OF POWER FROM UTILITY TO PRIVATE SUBSTATION. PC FOR NEW LOAD ON SUBSTATION AND NEW FAULT CURRENTS. REPLACEMENT OF EXISTING DISTRIBUTION PANELS AS WELL. THIS IS PART OF ""THE VILLAGE"" DEVOPLEMENT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44544	17041-20000-07108	945 S BOYLE AVE	90023	14	124-5A221 278	5189001047	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.03444	-118.21956	ti to an existing commercial space.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy only.  total square footage 5830.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44545	18041-20000-41083	6922 W HOLLYWOOD BLVD 11th Floor	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.10137	-118.34103	Plan check for Title 24 only. Project site is the 11th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,890 sq. ft.Note: Building application has been generated under 18016-10000-08241.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44546	14041-10000-04611	5757 W CENTURY BLVD SUITE 700	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	33.9457	-118.38274	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BARRISTER SUITE. SUITE 700. 1010 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44547	15041-20000-16645	9012 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.23397	-118.55337	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,883 sq. ft.Note: Power portion of tenant improvement will be plan-checked and permitted under application number 15041-20001-16645.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44548	14041-10000-26037	624 S GRAND AVE SUITE 2950	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	PIN	34.04778206	-118.25563275	PLANCHEK FOR T24 ERNGY.  INTERIOR T.I., OFFICES. SUITE 2950. 3,654 SF.  PERMIT FOR LOW VOLTAGE SECURITY AND DATA, CKTS AND POWER EQUIP IN PANEL L28.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44549	15041-10000-14006	112 E 22ND ST BLDG 10	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	33.72783	-118.27968	NEW 1200 AMP SWITCHGEAR, RECONNECETING TO EXISTING EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44550	18041-10000-32281	12905 W LANDALE ST	91604	2	165B161    71	2362006013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	04/06/2021 12:00:00 AM	ADDRESS	34.15231	-118.414	PC FOR NEW FA IN 4 STORY BUILDING WITH UNDERGROUND GARAGE. TOTAL OF 61 INSTALLED DEVICES WITH 2 PANELS (FACP+RPS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44551	16041-20000-03230	1556 N HAZELWOOD AVE	90041	14	157-5A223  54	5474014017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.12463	-118.21435	Plan check for PV roof mounted system. System size: 5.7kW with 23 modules and 23 microinverters. PV connect to Supply side  of the service. PV ready service panel data sheet is provided.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44552	11041-20000-03944	6200 W WILSHIRE BLVD #1612	90048	5	135B177   512	5088015021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	04/08/2011 12:00:00 AM	ADDRESS	34.06295	-118.36347	energy plan check # 1612	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44553	13041-10000-06381	1755 N HIGHLAND AVE	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.10323	-118.33897	renovation of small offices in conference and buisness center on first floor of hotel. total area 924 sq ft. part of highrise. field verify rooom size of manager's ofice. greater than 100 sq ft = multi level lighting controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44554	15041-20000-43229	4960 N BEN AVE	91607	2	171B165  1156	2355011001	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.16104	-118.39418	PV1 roof top installation, 11kW AC(57) KU2656ZPA( 1) PVI-5000-OUTD-US-Z( 1) PVI-6000-OUTD-US***NOTE FEES DUE ARE $0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44555	18041-10000-29201	101 W MANCHESTER AVE	90003	9	097-5A203 326	6040011025	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	33.96025	-118.27434	P lan check for T24 only, replace to new lightings in the dining area, all other are existing to remain.((B# 18016-10000-23433))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44556	12041-10000-11042	8734 S BELLANCA AVE	90045	11	096B169   844	4125018007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Public Safety Only			05/14/2012 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	33.95765	-118.38038	REPLACING FIRE WARNING SYSTEM/ CENTRAL STATION MONITORING  WITH  UPDATED SYSTEM AT A ENTERPRISE RENTAL STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44557	19041-20000-02001	609 S SPRING ST	90014	14	129A211   233	5144002016	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.04577	-118.25139	pc t-24 only for resturant. 1010 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44558	16041-20000-36162	12630 W RAYMER ST	91605	2	186B161   566	2324003048	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Issued	12/28/2016 12:00:00 AM	ADDRESS	34.20343	-118.40847	Service upgrade from 200 to 600 A, and installation of new equipment, including nonstandard voltage class equipment - 380/220Y	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44559	17041-10000-29850	6678 W SANTA MONICA BLVD	90038	4	144B185   779	5532025001	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.09047	-118.33588	REPLACE LIGHTING FOR LED TYPE. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44560	14041-10001-08921	7634 N HINDS AVE	91605	6	186B169   135	2317006007	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	34.20945	-118.39093	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(13) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44561	17041-10000-34302	3449 S MCLAUGHLIN AVE	90066	11	117B157   624	4249022004	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.01524	-118.42991	Pv1 roof mounted system with (42) module and (1) (11.4)Kw inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44562	16041-20000-37189	13261 W PAXTON ST	91331	7	213B157   688	2523020025	(Q)M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.27702	-118.42191	800 amp service upgrade.  reconnect feeders.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44563	17041-20001-45607	3322 N SCADLOCK LANE	91403	4	159B145   468	2279028013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	12/29/2017 12:00:00 AM	ADDRESS	34.13153	-118.46782	expeditepv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44564	13041-20000-07665	12315 W TIARA ST pv-1	91607	2	177B165   819	2340003026	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.17846	-118.40133	PV-1. One 7kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44565	11041-10001-20785	500 S VIRGIL AVE	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Plan check for revision to approved plans. Removing five 200A meters and installing additional 800A meter section and panel for future tenant on 4th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44566	13041-20000-23648	1071 N BROOKLAWN DR	90077	5	144B157     2	4358007001	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.08724	-118.43086	New 800 amp service, generator, subpanels for an existing single family dwelling.  No branch circuits are to be installed in the panels.  Inspector may require plan review for new branch circuits, subject to field inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44567	19041-20000-53204	12905 W LANDALE ST	91604	2	165B161    71	2362006013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	34.15231	-118.414	INSTALL (53) NEW FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44568	14041-10000-00933	10767 W PICO BLVD	90064	5	126B157   815	4320003055	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM			PC Info Complete	05/01/2014 12:00:00 AM	ADDRESS	34.04105	-118.42693	TI retail lens crafters. 1 story , Power and energy. Building 14016-10000-00584: TI TO AN ( E ) RETAIL STORE AND CHANGE THE USE OF A PORTION OF THE BUILDING TO EYE EXAMINATION (medical)  AND LENS MANUFACTURING . not hazardous per engineer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44569	18041-20000-21868	1999 S AVENUE OF THE STARS 37th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 Energy only in existing high rise building Office T.I. 37th Floor for Deutsche Bank Total area: 9512 sq ft. B#18016-10000-17866	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44570	11041-10000-01759	5201 S HOOVER ST 3 OF 3	90037	9	108B197   156	5001003002	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Apartment			01/28/2011 12:00:00 AM			Corrections Issued	02/06/2011 12:00:00 AM	ADDRESS	33.99518	-118.28728	SERVICE UPGRADE TO 600 AMP FOR EXISTING 3 SEPARATE  APARTMENT BUILDINGS AND INSTALL A SUBPANEL AND CIRCUITS IN EACH UNIT.   (APP 3 OF 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44571	17041-20000-05748	1485 N BLUERIDGE DR	90210	5	147B157   267	4355008043	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.09795	-118.41941	Plan check for power only. Project site is a new single-family dwelling. Project scope is a new service, distribution equipment, and loads.Note: Electrical permit fees paid under 07010-10000-04806.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44572	15041-10000-13822	2330 W RIPPLE ST	90039	13	150A211    79	5437032015	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	ADDRESS	34.10672	-118.25294	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44573	17041-10000-35704	6255 W SUNSET BLVD #1800	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.09815	-118.32564	PC for T24 only for one to one replacement of flouresent fixtures to LED fixtures. Total area is 10726sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44574	10041-10000-07733	250 S ROSSMORE AVE	90004	4	135B185    14	5515013001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	07/13/2010 12:00:00 AM	ADDRESS	34.06991	-118.32716	TITLE 24 FOR OUT DOOR LIGHTS . LIGHTS REPLACED WITH MORE  EFFICIANT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44575	15041-10000-02494	1755 N HIGHLAND AVE 2ND-3RD	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.10323	-118.33897	T24 ENERGY ONLT FOR INTERIOR ALTERATION OF EXISTING LIGHTING IN LOEWS HOLLYWOOD HOTEL. TOTAL AREA 1946 SQ FT.(SECOND & THIRD FLOOR RESTROOMS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44576	14041-10000-25647	17237 W VENTURA BLVD #C	91316	5	171B133   679	2258012022	[Q]C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.16084	-118.50848	Title 24 plan check for a restaurant T.I.  remodeling includes partial of the partio and kitchen area, total is 1035 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44577	15041-20000-23323	21650 W OXNARD ST 15th&19th	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only for T.I. in corridor area in 15th and 19th Floor. Total corridor indoor area: 2,266sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44578	16041-20001-08862	8501 S SEPULVEDA BLVD	90045	11	096B165   278	4108019014	[Q]R3-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	33.96108	-118.39649	RSES expedite fee per applicant request.  PV2.  Installation of 20.4 kW roof-mounted PV system on (E) apartment building.  (3) 6 kW inverters with (66) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44579	17041-20000-33040	4105 S REDWOOD AVE	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	PIN	33.99074144	-118.44097396	Electrical room and restroom improvements to (E) commercial office shell space.  New rooftop HVAC units.  New load not exceeding 400A.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44580	13041-10001-05727	6600 N TOPANGA CANYON BLVD #51	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	DELTA 4 REVISIONS TO PERMITED SET OF LANS CHANGES ARE CLOUDED ON THOSE SHEETS THAT ARE REVISEDPLAN CHECK ONLY((((((((PLAN CHECK FOR POWER AND ENERGY FOR EXISTING RESTUARANT SPACE (CHANGING FROM CALIFORNIA PIZZA KITCHEN TO CHEESECAKE FACTORY).INDOOR AND OUTDOOR LIGHTING: 17130 SQRFT. SERVICE UPGRADED TO 1200A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44581	18041-10000-18960	750 S WESTERN AVE SUITE A	90005	10	132B193   536	5093007021	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.05823	-118.30888	CHANGE OF USE WITH TENANT IMPROVEMENT FROM (E) RETAIL  TO FOOT MASSAGE PARLOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44582	10041-10000-09239	1829 S WESTERN AVE	90019	10	126B193   747	5073013006	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	05/17/2010 12:00:00 AM		Permit Expired	09/26/2012 12:00:00 AM	PIN	34.04092388	-118.30934236	New fire sprinkler monitoring.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44583	17041-20001-10131	15220 W ANTELO PL	90077	5	159B145   589	4378005008	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2017 12:00:00 AM			PC Approved	05/19/2017 12:00:00 AM	ADDRESS	34.12922	-118.46269	Install 7.93 kW roof mounted grid-tied PV system.  (26) modules with (1) 6kW rated central inverter with power optimizers.  Connecting to (E) 8kW rated PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44584	18041-10000-28748	333 S GRAND AVE 16th FL	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	INTERIOR OFFICE TENANT IMPROVEMENT OF 8,182 SF ON THE 16TH FLOOR OF (E) OFFICE BUILDINGPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44585	17041-20000-45219	10668 N TELFAIR AVE	91331	7	207B157   610	2619018012	R1-1VL-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Issued	01/11/2018 12:00:00 AM	ADDRESS	34.26417	-118.42601	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.75 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44586	18041-10000-24129	7602 N SAN FERNANDO ROAD	91352	2	186B177    76	2405006023	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.20989	-118.35448	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44587	17041-20001-09381	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2017 12:00:00 AM			PC Approved	04/12/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	expedite.pv1install roof mounted pv system sized 6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44588	18041-20000-32159	5147 S WEST BLVD	90043	8	108B185    96	5013003007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	33.99531	-118.33568	Plan check for PV roof mounted with battery back up sysgtem, system size: 7.6kW with 11 modules, 1 inverter(7.6kW) and 1 LG Chem RESU 9.8kWh	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44589	17041-20000-42364	9841 N AIRPORT BLVD 8TH FLR	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Issued	11/22/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	PLANCHECK FOR T24 ENERGY.  TI TO COMMON COORIDOR AND RESTROOM UPGRADES. 2048 SQFT.  8TH FLOORBUILDING P# 17016-10000-18339	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44590	11041-20000-04623	21700 W OXNARD ST 16th Floor	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.17901	-118.60179	T.I. to existing high rise building.  Install general/emergency on 16th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44591	17041-20001-28529	2226 S OVERLAND AVE	90064	5	126B157    48	4320007027	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.04529	-118.42738	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with DC coupled battery backup system.6.8kW-AC ungrounded system. (1) Schneider Electric XW+ 6848NA inverter.(4) 12V 104AH batteries.(20) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44592	16041-10000-01234	16736 W VALERIO ST	91406	6	186B137   235	2226020010	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	PIN	34.20469833	-118.49773872	PV1 INSTALL 3.42 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: SOLARWORLD SW 285 MONO 285 W(12) MICRO INVERTER : ENPHASE M25060-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44593	15041-10000-39227	4016 N PORTOLA AVE	90032	14	145-5A235 244	5307015029	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2011.10	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.09232	-118.17201	PV1,  roof mounted solar system installation for a single family home. Scope: (1) Inverter: 7kw. (21) Solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44594	18041-10002-06179	1925 S TUDOR LANE	90034	10	126B173  3095	6207036031	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM			Reviewed by Supervisor	02/28/2018 12:00:00 AM	ADDRESS	34.04074	-118.37113	Supplemental for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44595	19041-20000-45661	6025 N MORELLA AVE	91606	2	177B169   718	2334016032	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.18024	-118.39009	PV1. INSTALL 4.62 KW DC ROOF MOUNTED PV SYSTEM WITH (14) MODULES/OPTIMIZERS AND (1) INVERTER (SE3800H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44596	17041-20001-29159	19161 W ARMINTA ST	91335	3	189B121   301	2104006026	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.21392	-118.55141	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Systems size is 14.4 kWac and consists of (2) inverters and (46) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44597	17041-20001-14641	4161 N FARMDALE AVE	91604	2	162B169    52	2368022016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.14418	-118.38128	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system and a Tesla AC Powerwall to an existing PV system. PV system addition size is 3 kWac and consists of (1) inverter, (8) modules, and (1) load center. Tesla AC Powerwall rating is 7 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44598	18041-10001-05964	1339 N AVENIDA DE CORTEZ	90272	11	138B117   338	4431005029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.07166	-118.56009	PC CHANGE OF AN APPROVED SET FOR PV. SCOPE INCLUDES ADD A LOAD CENTER AND A DISCONECT SWITCH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44599	10041-10000-05078	433 E TEMPLE ST BLDG 5-Space #108	90012	14	130-5A215 253	5173007901	PF-1XL	Central	Central City North	Historic Cultural		2060.30	Electrical	Electrical	Commercial			03/19/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	06/09/2010 12:00:00 AM	ADDRESS	34.05068	-118.23686	TI IN AN EXISTING OFFICE SPACE IN BUILDING # 5 SPACE #108. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44600	17041-30000-01171	13767 W FOOTHILL BLVD	91342	7	225B153   444	2509015007	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	11/24/2017 12:00:00 AM	ADDRESS	34.31003	-118.43331	Plan check for power and Title 24.  Total area = 13,852 sq. ft. (indoor) + 7,502 sq. ft. (outdoor).New single story retail building with 600 Amp 120/240 three phase delta service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44601	18041-10000-33619	10901 W BLIX ST	91602	2	168B173   548	2421015020	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.15674	-118.36816	INSTALL A NEW FIRE ALARM SYSTEM IN AN APARTMENT BUILDING WITH 41 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44602	14041-10000-05833	10959 W SANTA MONICA BLVD	90024	5	129B153   582	4324029015	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	PIN	34.04927048	-118.44020768	T24,REMOVING EXISTING FIXTURES WITH NEW FLORESCENT LIGHT FIXTURES. TOTAL AREA 8224 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44603	19041-10000-36384	904 S NORMANDIE AVE	90006	10	132B197   851	5094022008	R4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.05	Electrical	Electrical	Apartment			09/12/2019 12:00:00 AM			Verifications in Progress	12/16/2019 12:00:00 AM	ADDRESS	34.05565	-118.29966	FULL PC FOR A NEW 1000A SERVICE (120/208) THAT FEEDS A 400A HOUSE DISTTRIBUTION BOARD AS WELL AS A 600A MULTI METERING CENTER. THE METERING CENTER FEEDS 29 SUBPANELS. TOTAL AFFECTED AREA IS 17,564 SFQT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44604	18041-20000-41631	7213 W MELROSE AVE	90046	5	141B181   550	5525011035	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.08362	-118.34664	Plan check for Title 24 only in existng space T.I. Total area: 2464 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44605	18041-20000-18841	21725 W CALIFA ST	91367	3	177B105    98	2146006048	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.17746	-118.6019	Installation of (20) EV charging stations in (E) commercial parking garage supplied by new 150 kVA transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44606	16041-20001-35123	20126 W JUBILEE WAY	91326	12	213B113   407	2701087040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2017 12:00:00 AM			PC Info Complete	02/27/2017 12:00:00 AM	ADDRESS	34.28234	-118.57251	(2/27/2017)changes to an approved set of plans.  reduce number of modules to 18 total.  standard plan.pv1install roof mounted pv system (acm) sized 6kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44607	16041-20001-07538	120 S RENO ST	90057	13	138A201   373	5155004025	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.07077	-118.28154	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM 2 SIZE: 61.9 KW.TOTAL SYSTEM SIZE: 234 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44608	10041-20000-23544	251 S BERENDO ST	90004	1	132A201    60	5077022002	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			11/24/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	34.06935	-118.29432	renovate and service upgrade to 600 A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44609	14041-10001-24941	5501 N WILLIS AVE	91411	4	174B149  1087	2249027015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.17046	-118.45546	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 5.355 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(21) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44610	15041-10000-38580	21525 W DEVONSHIRE ST	91311	12	204B105   860	2722007052	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	ADDRESS	34.2574	-118.59907	CHANGE OF USE FROM BANK TO A HEALTH CLUBplan chk is for Title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44611	19041-10000-20078	21851 W ECCLES ST	91304	3	192B101   375	2779039024	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.2229	-118.60465	PC FOR PV SYSTEM. SYSTEM SIZE IS 5.605KW. SYSTEM CONSISTS OF (19) HANWHA Q-CELL MODULES W/(19) P320 OPTIMIZERS, (1) SE3800 SOLAREDGE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44612	15041-20000-13141	10045 S WESTERN AVE	90047	8	091-5A193 170	6058006007	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	33.94405	-118.3093	Plan check for new service and equipment for 600A connected to 7class rooms building(pre build and approved by the State of CA). Approved building permit per State of CA is included.final fee adjustment OK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44613	15041-20000-14721	723 N LILLIAN WAY 1-7	90038	13	141B185   460	5533032017	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			05/14/2015 12:00:00 AM			PC Info Complete	10/07/2015 12:00:00 AM	ADDRESS	34.08416	-118.328	Plan check for power and energy for a 7-unit apartment building. Work includes a new 600-amp service, the installation of (13) panels, and a total lighting area = 6,950 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44614	15041-20004-08533	6344 N TOPANGA CANYON BLVD #1050	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	"09/09/2015 Changes to an approved set of plans. Changes include the addition of a fused disconnect on the secondary side of the transformer and changing the feeder. All changes have been clouded and marked as Delta 5.*****Previous Work Description*****Changes to an approved set of plans. Delta 3 changes. Changing 65W light fixture with 50W.(((Plan check for power and energy for first time tenant (new restaurant = Tender Greens). Total area: 3177 sq ft. Part of Building A of ""Westfield Topanga"" mall.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44615	19041-10000-52789	11847 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	09/30/2021 12:00:00 AM	ADDRESS	34.28595	-118.38982	T-24 PLAN CHECK FOR A TI TO OUTDOOR PRIVATE STREET LIGHTING. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 58976 SQ.FTCHANGE OF CONTRACTOR FROM MARK THOMAS LOVEQUIST TO BRETT CHRISTOPHER TREBIL.SAME ENGINEER ON RECORD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44616	12041-10000-18340	3000 W RIVERSIDE DR	90039	4	151-5A207  18	5434024001	CM-1VL	Central	Hollywood	Silver Lake	YES	1882.01	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Issued	08/06/2012 12:00:00 AM	ADDRESS	34.11129	-118.26581	Plan check for energy. Outdoor. 250 sqft. Verizon Tower.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44617	18041-20005-36457	11419 N MONTALCINO WAY	91326	12	213B109   412	2701068023	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.27907	-118.58671	CHANGES TO APPROVED SET DELTA 3 ONLY. REMOVING HEAVY DUTY AC DISCONNECT AND RELOCATING BACKUP GATEWAY. <<<Plan check for the addition of (3) Tesla PowerWalls to an existing roof-mounted PV system.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44618	13041-20000-09407	333 S HOPE ST STE 1000	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for energy and emergency lighting. High-rise commercial. 10th floor. Suite 1000. CAP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44619	17041-10000-06708	3254 N VERDUGO ROAD	90065	1	150B213    91	5456002033	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.11117	-118.23608	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR) TOTAL AREA 8463 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44620	12041-20000-15176	1168 S BARRINGTON AVE	90049	11	129B145  1183	4265001039	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			06/28/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.0499	-118.46096	Fire alarm system for 78 UNITS APARTMENT BLDG, 6 STORY, 2.5 LEVELS PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44621	16041-10000-20095	301 W OLYMPIC BLVD Loit LA	90015	14	127-5A209 251	5139004026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.04182	-118.25852	Full PC, Change of use from Retail to Restaurant in (E) MIxed use Build. New connected load < 400A, total area: 7,662 sq.ftB# 16016-10000-09083	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44622	11041-10000-04869	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	08/24/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI IN AN EXISTING OFFICE BLDG. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44623	18041-10000-06490	800 S FIGUEROA ST 6,7,8,9,10-12 FLR	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.04771	-118.26116	"Plan check for emergency exit signs only, located on the 6th, 7th, 8th, 9th, 10th, and 12th floor elevator lobbies and corridors. Exit signs are dual circuits that connect to the nearest normal lighting circuit in the area and to the existing emergency lighting branch circuit from panel 9EH. (18) exit signs total.******Note to permit staff: Permit fee is under ""inspection"" fee period********"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44624	14041-10000-25795	4333 W WILSHIRE BLVD	90010	4	132B189    17	5505029012	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.06197	-118.32252	Title 24 plan check for new lighting in converting offices and fix partitions in a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44625	18041-10000-12480	937 N CITRUS AVE	90038	4	144B181   680	5532011034	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			Corrections Issued	04/14/2018 12:00:00 AM	ADDRESS	34.08825	-118.33978	PLANCHECK FOR POWER ONLY. New 1600 service, service equipment, and feeders for existing building.  Reconnect the existing subpanels to the new service.  recheck due to expired plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44626	14041-10000-17614	8935 N ORION AVE	91343	7	195B141   247	2654001024	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.05	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.23288	-118.4722	PC FOR POWER AND ENERGY. 3 STORY BUILDING. (33) UNITS OVER BASEMENT PARKING.  7 TYPES APARTMENT. TOTAL AREA 20265 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44627	14041-10000-04428	1458 S SAN PEDRO ST #L-08	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in commercial retail space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44628	18041-10000-41889	10201 W PICO BLVD STAGE 17	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	FIRE ALARM WARNING SYSTEM WITH 24 HR SUPERVISORY MONITORING STATION IN A COMMERCIAL BUILDING. 58 DEVICES AND 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44629	13041-10000-01092	621 S WESTERN AVE #102	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	TENANT IMPROVEMENT IN RETAIL SPACE THAT HAS BEEN VACANT FOR A LONG TIME-FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44630	11041-10000-01112	4800 W HOLLYWOOD BLVD	90027	13	147B197   255	5543009900	OS-1XL	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	07/29/2011 12:00:00 AM	ADDRESS	34.10153	-118.29439	Ti in a storage area of an existing park. EPC is for T24 & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44631	13041-20000-12497	11720 N SEMINOLE CIR	91326	12	213B117    96	2822024010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.28307	-118.55901	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 13.520 KW. NEGATIVELY GROUNDED. [SOLAR MODULE: LG260S1C-G3] [INVERTER: (2) SUNNYBOY SB6000US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44632	15041-20000-23587	5757 W WILSHIRE BLVD #124	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.06259	-118.35341	PC FOR T24 ENERGY ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44633	18041-20001-24593	24016 W BESSEMER ST	91367	3	177B089   449	2045006017	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.18124	-118.65025	Expedite per applicant reqeust Plan check for PV roof mounted system, 15.2kW with 40 modules and 2 inverters(7.6kW) connected to MSP 200A panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44634	18041-10000-31235	8929 N FULLBRIGHT AVE	91311	12	195B109    51	2781001033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.23296	-118.57773	REPLACE FLUORESENT TROFFERS WITH NEW LED RETROFIT KITS & REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. (OUTDOOR & INDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44635	10041-10000-12118	267 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY POWER TO CONSTRUCTION TRAILER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44636	15041-20000-11091	6256 N TOPANGA CANYON BLVD C-1390	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	T. I. IN GROUND FLR FOR RADIO STATION pc for power and energy. part of westfield development	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44637	17041-20000-30132	22257 W MACFARLANE DR	91364	3	171B101   553	2075006017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.1654	-118.61224	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44638	19041-10000-07501	716 N LA BREA AVE	90038	5	141B181   533	5525008028	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Re-Activate Permit	11/26/2019 12:00:00 AM	ADDRESS	34.08398	-118.34386	Change of use from Retail to Museum (Fruit) (116' x 98'). Installing new lights. T-24 Energy Only.Bulding Permit: 19016-10000-02177	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44639	19041-10000-53781	10801 W VENICE BLVD	90034	5	117B161   566	4252029035	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			12/30/2019 12:00:00 AM	11/14/2022 12:00:00 AM		Issued	11/14/2022 12:00:00 AM	ADDRESS	34.01788	-118.4092	PLAN CHECK FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW 2000A SERVICE (120/208 3P,4W) SERVICE FEEDS A NEW 2000A SWITCHBOARD WHICH FEEDS A 600A BOARD FOR FUTURE RETAIL/RESTAUARNT. SERVICE ALSO FEEDS 800A MULTI-METERING SWITCHBOARDS. TOTAL AFFECTED AREA IS 51,520 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44640	19041-10001-30563	21829 W MICHALE ST	91304	3	192B105    39	2779029009	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.22655	-118.60389	CHANGES TO APPROVED SET OF PLANS - RELOCATION OF SERVICE AND INVERTER LOCATION TO BACK OF HOUSE. CHANGES HAVE BEEN CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44641	16041-30000-23386	9501 S AVIATION BLVD	90045	11	093B173   221	4128001008	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	33.95061	-118.37764	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 24KW INTERCONNECTED WITH MSP.(117) SOLARFUN MODULES(3) SMA 8000 INVERTERS$0 permit fee is due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44642	19041-10000-18434	1130 W BROWNING BLVD Unit 1-5	90037	8	114B197    95	5037025007	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Apartment			05/17/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	01/05/2021 12:00:00 AM	ADDRESS	34.01183	-118.2952	NEW 5-UNIT 2-STORY TOWNHOUSE WITH ATTACHED GARAGE WITH A 600AMP SERVICE.BULDING PERMIT: 18010-30000-03905	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44643	19041-10000-24683	6929 N LAUREL CANYON BLVD	91605	2	183B165   366	2321010058	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.19642	-118.39672	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44644	14041-20001-23152	18241 W DONMETZ ST	91326	12	210B125   158	2715032026	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.27409	-118.53104	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 12KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44645	18041-10000-08042	15648 W ROXFORD ST	91342	7	225B145   446	2501004025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.31052	-118.47222	REPLACE INDOOR-OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 62725 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44646	13041-10000-09766	720 N EAST KENSINGTON ROAD	90026	1	136-5A211 162	5405023013	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Apartment			04/16/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.06881	-118.25159	PV2 APARTMENT HOUSE. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 2.45 KW. PART OF SUBMITTAL 2 OF 3. LOCATED ON SAME STRUCTURE BUT CONNECTED TO DIFFERENT SERVICE. USING 10 PANELS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. LOCATION IN METHANE ZONE, NO UNDERGROUND WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44647	17041-10000-12565	5778 W OLYMPIC BLVD	90036	4	132B177   764	5085004036	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			04/18/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.05716	-118.35574	Plan check for new  Fire alarm system on appartment building 4 story  12 units. Total devices: 77 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44648	12041-20000-23022	13315 W VICTORY BLVD	91401	2	180B157  1147	2329024012	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.18685	-118.42319	New service, panel, and circuits for a new retail store.   Plan checked for T-24 lighting compiance only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44649	11041-10000-19423	10345 W WILKINS AVE	90024		132B157    68	4327010012	[Q]R3-1-O		Westwood				Electrical	Electrical	Apartment			09/13/2011 12:00:00 AM			PC Approved	09/13/2011 12:00:00 AM	ADDRESS	34.06158	-118.42489	"DELTA 1 REVISION TO APPROVED PLANS UNDER PCIS 10040-10000-03331:  Replace (4) sets of  3""C-4#350 KCM Cu each with (3) sets of 4""C-4#500 KCM Cu each. (See Dwg. E-2)NO CHANGE IN PERMIT PREVIOUSLY ISSUED UNDER PCIS 10040-10000-03331."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44650	19041-10000-11638	1538 S COMSTOCK AVE	90024	5	135B157   634	4327021006	R1V3-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	05/04/2019 12:00:00 AM	ADDRESS	34.06221	-118.42313	PLAN CHECK FOR ENERGY STORAGE SYSTEM CONNECTED TO EXISTING PV SYSTEM, WITH RELOCATION OF BACK UP LOADS.PV ONLINE PERMIT # 18041-90000-34664	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44651	17041-20000-16865	22106 W CLARENDON ST	91367	3	174B101   483	2169026083	CR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.16948	-118.60841	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,907 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44652	12041-10000-00049	5767 W ADAMS BLVD	90016	10	123B173   849	5048007032	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2184.00	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	34.0326	-118.36937	New 10.6kw rooftop, photovoltaic system for a commercial building with 3 inverters and 38 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44653	18041-20000-28313	20751 W MARILLA ST	91311	12	201B109   151	2748004043	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Issued	01/11/2019 12:00:00 AM	ADDRESS	34.24825	-118.58596	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  Plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44654	17041-10000-28673	10000 S FIGUEROA ST	90003	8	091-5A201 113	6054033040	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	33.94532	-118.2824	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY. TOTAL SQ FT 16000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44655	10041-10000-12286	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	07/12/2010 12:00:00 AM		Permit Expired	08/08/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	REMODEL THE GAP RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44656	19041-10001-50143	11401 N PORTER RANCH DR	91326	12	213B113   481	2701100004	C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			12/05/2019 12:00:00 AM			PC Approved	02/19/2020 12:00:00 AM	ADDRESS	34.2779	-118.57107	Expedite Fees.Plan check for PV solar system. System size 178KW. (400) modules, (3) inverters,***INSTALLATION OF (3) SOLAR CANOPIES WITH 178 kW (AC) SOLAR CONSISTING OF (400) SPR X22-470-COM SOLAR MODULES1 OF 14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44657	19041-10000-17997	777 S FIGUEROA ST 3700	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Issued	06/05/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	T-24 PLAN CHECK FOR AN INTERIOR TI FOR EXISTING OFFICE. SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 6200 SQ.FT.TOTAL CONNECTED LOAD IS LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44658	14041-20001-17199	5732 S CELEDON CK	90094	11	102B157   313	4211024***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	33.97471	-118.42179	For expedite fee only.*****New roof mounted PV system, total system size 5.36KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44659	10041-10000-06134	110 N GEORGE BURNS ROAD 6th fl	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	04/05/2010 12:00:00 AM		Permit Finaled	08/18/2010 12:00:00 AM	ADDRESS	34.07564	-118.38149	T.I. for Cedars-Sinai.  Replace lighting fixtures in physiology room 6006 as shown on plan.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44660	19041-10001-00182	3475 S STONER AVE	90066	11	117B153  1102	4249015003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.01339	-118.43259	SUPPLEMENTAL PLANS CHECK FOR CHANGES TO APPROVED SET - CHANGES INCLUDE REDUCTIONF OF MODULES FROM 28 TO 19(SOLAR CITY SC325) WITH CHANGES TO INVERTER (DELTA SOLIVIA 7.6) USING RAPID SHUTDOWN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44661	17041-10000-08868	457-465 W 7TH ST	90731	15	015B201   179	7455006006	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	03/31/2021 12:00:00 AM	ADDRESS	33.73769	-118.28698	FULL PC FOR POWER AND ENERGY TI TO (E) TWO STORY RESTAURANT. CHANGE OF USE OF (E) TELEPHONE CENTER INTO RESTAURANT. SCOPE INCLUDES A NEW 800A 120/240V 3 PHASE, 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 7211 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44662	15041-20000-01844	416 W 8TH ST	90014	14	127-5A209  58	5144018030	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.04471	-118.25646	High rise 13 stories. Adaptive reuse to hotel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44663	19041-20000-41438	8167 S ZITOLA TER	90293	11	096B153   544	4115006012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.95972	-118.44369	Plan check for PV roof mounted system, PV system size: 14.0KW DC, 12.73KW AC CEC with 35AC Modules, sub-panel connected to MSP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44664	18041-20000-16433	5285 W WASHINGTON BLVD	90016	10	126B177   913	5064004012	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.04095	-118.3571	Change of use from retail to office and accessory storage.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44665	13041-20000-28394	7032 N DEERING AVE	91303	3	183B105   550	2138015008	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.19831	-118.59643	FULL PLAN CHECK FOR NEW GARAGE/OFFICE BUILDING. SERVICE SIZE 200A. FULL PLAN CHECK PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44666	16041-10000-18921	1914 S MATEO ST	90021	14	120A217    73	5167011037	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.02305	-118.23225	T-24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 19588 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44667	18041-10000-49190	2330 E CESAR E CHAVEZ AVE	90033	14	129A223   338	5183004018	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM			PC Info Complete	12/31/2018 12:00:00 AM	ADDRESS	34.04676	-118.20816	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 1304 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44668	14041-10002-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			08/02/2016 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Closed	05/14/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	** Changes to approved set, noted under Delta-7 only.Changes include: revise all meter banks and electrical room;  change wire type from partial Copper to ALL Aluminum;  revise feeder schedules;  revise panel schedule, adding new loads;  revise lighting plan, update light schedule.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44669	17041-10000-34331	2325 W SAN FERNANDO ROAD	90065	1	150B213   705	5457009008	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM			PC Info Complete	09/25/2017 12:00:00 AM	ADDRESS	34.10531	-118.23862	PC FOR POWER UPGRADE. NEW 800A SECTION TO PROVIDE NEW 400A SWITCHBOARD AND REFEED EXISTING 400A SECTION. PC FOR NEW SERVICE, 2 PANELS, NEW SHORT CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44670	19041-10000-41800	3212 E OLYMPIC BLVD	90023	14	118-5A223  65	5190028006	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	05/19/2020 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.01963	-118.20987	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS CHANGE OF USE FROM A MANUFACTURING SPACE TO CATERING ESTABLISHMENTS (10 INDIVIDUAL KITCHENS). SCOPE OF WORK INCLUDES A NEW 800A SERVICE (3P, 4W) (208/120V) FEEDING A 800A MAIN SWITCHBOARD THAT SUBFEEDS 11 SUBPANELS. TOTAL AFFECTED AREA IS 5924 SQFT. B#19016-10000-32585	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44671	18041-10000-43493	8415 S PERSHING DR	90293	11	096B153   953	4116023023	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	33.95685	-118.44296	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44672	13041-20001-35636	11554 W CANTON DR	91604	2	159B169   356	2377016018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.13293	-118.38551	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 2 TRANSFORMERLESS INVERTERS, NONSTANDARD PLAN. ALL ROOF MOUNTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44673	16041-10000-30763	1220 N NORTH SPRING ST	90012	1	135A217    30	5409006030	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.06577	-118.23347	PC for energy only to existing building. Change of use from warehouse to restaurant and brewery. Scope includes adding new panels, new receptacles, and new lights. Total sqft = 5616.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44674	16041-20001-22509	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM			PC Approved	02/08/2017 12:00:00 AM	ADDRESS	34.04403	-118.2199	Revisions to approved set.  Changes made to (E) service details to reflect (E) site conditions, change to PV distribution AIC rating.  Changes only affect sheet PV-8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44675	17041-30000-25499	801 S FIGUEROA ST 3rd Floor-Elev Lobby	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the elevator lobby on the 3rd floor of an existing commercial building. Project scope is new lighting system. Total lighting area = 300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44676	15041-20000-38392	10357 N HAINES CANYON AVE	91042	7	204B201   261	2569023040	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.25732	-118.2785	"""0$ permit fees due to senate bill 1222""PV1. Install roof mounted PV system sized 20 kW. Interconnected with main service panel.(68) SOLARWORLD SW285 Modules(68) OP 300-MV Power Optimizers(2) SOLAR EDGE SE10000 TL Inverter"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44677	12041-20000-17955	18055 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM			PC Approved	09/07/2012 12:00:00 AM	ADDRESS	34.2648	-118.52595	INTERIOR TENANT IMPROVEMENT OF (E)RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44678	18041-10000-32738	9727 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			PC Info Complete	10/31/2018 12:00:00 AM	ADDRESS	34.24624	-118.4193	Install New 200A, 277/480 V, 3ph, 4W service to provide power to (2) Level 3 EVCS and (2) 30kWh/60kWh Battery Energy Storage. Scope includes (1) 1.5 kVA step down transformer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44679	15041-20000-05726	915 W WILSHIRE BLVD STE 1700	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Expired	03/27/2017 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI TO OFFICE IN SUITE 1700. NEW LIGHITNG AND NEW CONTROLS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44680	14041-20000-00055	6960 N RUBIO AVE	91406	6	183B137   280	2225006034	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.19729	-118.49548	PV1 SINGLE FAMILY DWELLING. TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL SYSTEM SIZE 6KW AC USING 28 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44681	19041-10000-30301	17950 W PARTHENIA ST	91325	12	195B129   429	2787001019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.22845	-118.52472	REVISION TO 18041-10000-15377/19041-10000-14157: CHANGES ARE NOTED UNDER DELTA#2 WHICH INCLUDE  MSP AND BREAKER RATINGS 10/22KAIC. Inspection fees are $0 due to plan being a plan check only, no new  equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44682	14041-20001-34285	9410 N WOODLEY AVE	91343	12	198B141   197	2671015003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.24142	-118.48481	[[[[ 1/27/15 SUPPLEMENTAL PLANCHECK ONLY. CHANGING # OF MODULES TO 36 ]]]]]]]]PV1. INSTALL ROOF MOUNTED SOLAR ARRAY. INTERCONNECTED WITH MAIN SERVICE PANNEL. SYSTEM SIZE 7.5 KW.(39) KYOCERA KU2556XCA MODULES(1) FRONIUS IG PLUS INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44683	12041-10000-26948	3703 N BEVERLY RIDGE DR	91423	5	162B149   488	2274016011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.13797	-118.44763	ROOF MOUNTED SOLAR, 43 MODULES 10KW (225A UPGRADE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44684	15041-10001-23174	929 S NEW HAMPSHIRE AVE	90006	10	132B197  1000	5094025015	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.05485	-118.29302	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8 KW INTERCONNECTED WITH MSP.(12) SUNPOWER 327W MODULES (1) SMA SB-3800TL-US -22 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44685	10041-20000-17014	14255 W DELANO ST	91401	6	177B153   452	2240020025	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.18278	-118.44413	6 units- 3stories aparment with first floor as parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44686	14041-20001-24915	7014 S HOOVER ST UNIT 7	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 7.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44687	15041-30002-41295	9600 N LURLINE AVE	91311	12	201B109   290	2748040027	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.24455	-118.58404	03-03-16 Change to approved set of plans. Changes include line side connection to load side connection.  Circuit Breaker are not being use in the main panel; Instead, use 125A fuse as overcurrent device with 200A disconnect switch.  To Inspector: Please verify the AIC and SCCR of the Fuse and Disconnect to match the ratting of the Main Switch Board. {{{{{{{NEW DESIGN. INSTALLING 3 INVERTERS. 108 MODULES TOTAL. SYSTEM SIZE 34KW AC. LINE SIDE CONNECTION}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44688	13041-10000-35970	423 E 11TH ST	90015	14	124-5A209  50	5145019019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.03682	-118.25442	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 1718 SQ FT. REPLACING TOTAL OF 2 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44689	10041-10000-04184	4520 W ELECTRONICS PL	90039	13	162B205    11	5593012025	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Public Safety Only			03/09/2010 12:00:00 AM			PC Info Complete	04/09/2010 12:00:00 AM	ADDRESS	34.14462	-118.27312	NEW FIRE LIFE SAFETY SYSTEM IN THE BUILDING.  POWER AND ENERGY SUBMITTED UNDER #10041-10000-04183.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44690	19041-10000-08461	555 W 5TH ST 29th Floor	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	T-24 PLAN CHECK FOR A TI OF AN OFFICE AREA IN A HIGHRISE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 8360 SFB# 19016-20000-06235	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44691	11041-10001-25989	189 S THE GROVE DR STE C-10	90036	4	138B177  1132	5512003042	C1.5-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Approved	06/07/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	PLAN CHECK FOR DELTA 1 REVISION FOR LIGHTING FIXTURES CHANGES AND T24 CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44692	19041-10000-01661	10224 N HAYVENHURST AVE	91343	12	204B137   434	2678022040	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.25639	-118.49343	PC FOR PV SYSTEM. 6.405 KW SYSTEM. 21 MODULES HANWHA, Q.CELL - Q.PEAK 4.1 305P. 21 OPTIMIZERS SOLAR EDGE P320. 1 SOLAREDGE 6000H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44693	15041-20001-01729	19400 W CRYSTAL RIDGE LANE	91326	12	219A119   116	2701007022	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.29496	-118.55675	06-30-2015 Change to approved set of plans. Changes include module layout, reduce number of modules from 21 to 17 modules. [[[[[PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44694	17041-10000-05495	5555 W MELROSE AVE RODDENBERR-BLDG	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Issued	02/21/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING(RODDENBERRY BLDG). SCOPE INCLUDES 126 FA DEVICES, AND 5 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44695	11041-10000-07287	16259 W STAGG ST	91406	6	189B137    57	2205004033	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	05/24/2011 12:00:00 AM		Permit Finaled	07/01/2011 12:00:00 AM	ADDRESS	34.21325	-118.4872	EXISTING PHARMACY. ADDITION OF A CLEAN ROOM, 3 NEW PANELS AND EMERGENCY GENERATOR.  FULL PLAN CHECK WITH LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44696	11041-10000-05073	7238-7248 N CANBY AVE	91335	3	186B125   921	2119021032	(T)[Q]R4-1-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.20236	-118.5346	CONSTRUCT A NEW 3 STORY, WOOD FRAMED 98 UNITS APARTMENT BUILDING OVER AN ON-GRADE CONCRETE PARKING STRUCTURE.  EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44697	15041-10001-18181	12903 W DESMOND ST	91331	7	216B161   484	2527005017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	PIN	34.28623013	-118.41360072	Revisions to approved plans.  Addition of AC disconnect next to MSP.  (((ROOF-MOUNTED PHOTOVOLTAIC SYSTEM  6KW AC)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44698	17041-20000-22566	6240 W SUNSET BLVD	90028	13	147A189    64	5546025003	(T)(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	07/02/2021 12:00:00 AM	ADDRESS	34.09778	-118.32504	New 7 story mixed use building with 200 dwelling units.  3000A 480/277V 4w 3ph service.Building permit issued under 17010-10000-00622.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44699	15041-10001-44013	2531 N SILVER LAKE TER	90039	4	150A207   323	5439020014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.10391	-118.26161	Expedited per customer request. (((PV1 installation to a single family home. (2) Inverters total rating: 11kw, (47) solar modules, Load center 100 amps.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44700	13041-20001-35203	7043 N DELCO AVE	91306	3	183B109   324	2136003014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.19868	-118.57876	((EXPEDITE FEE))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9KW AC USING 2 TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 44 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44701	14041-20000-00334	10451 W BELLAGIO ROAD	90077	5	141B153   180	4362020004	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2014 12:00:00 AM			Not Ready to Issue	06/16/2015 12:00:00 AM	ADDRESS	34.08138	-118.43908	pc for power and energy. NEW SFD, 2-STORY W/ BASEMENT GARAGE (13010 10000 04375). with 60kw optional standby generator  (Plan check per 2010 LAEC)Note: Electrical permit fees have been paid under building application number 13010-10000-04375. Building was issued as a combination permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44702	14041-20002-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			04/06/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Expired	09/13/2018 12:00:00 AM	ADDRESS	33.95605	-118.38499	New service to accommodate addition of (98) EV chargers to parking garage.  Miscellaneous revisions.  Delta-4 revisons only.  (((New 4-story 61 unit apartment over 2 levels of subterranean parking.  Plan check for power and energy.*3/24/16: Extension filed. Last date to obtain the permit is on 6/13/16)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44703	18041-10000-25553	3010 S CRENSHAW BLVD	90016	10	120B185   493	5051029002	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.0272	-118.33491	PLAN CHECH FOR T24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44704	17041-30000-11756	3330 N CAHUENGA BLVD WEST #505	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Approved	04/11/2017 12:00:00 AM	ADDRESS	34.13099	-118.35061	Plan check for Title 24 only in existing space T.I. in office space. Total area: 1,080 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44705	17041-20000-23699	5021 N MONTEZUMA ST	90042	1	151-5A225  85	5469009039	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.11089	-118.20564	INSTALLATION OF ENERGY STORAGE SYSTEM + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.3 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44706	11041-10000-02572	11066 W SANTA MONICA BLVD	90025	5	129B153   827	4323020025	C2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.04767	-118.44332	Ti for a restaurant. New panel board, circuits & T24 calc. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44707	17041-10000-45503	10660 W WILSHIRE BLVD	90024	5	132B153   163	4326001***	[Q]R5-3-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	01/07/2018 12:00:00 AM	ADDRESS	34.06075	-118.43529	REPLACE OUTDOOR HID LUMINAIRES ON BUILDING WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44708	16041-10000-20299	12755 W BLUFF CREEK DR	90094	11	102B161  1270	4211037208	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	33.9747	-118.41609	PC FOR A NEW FIRE ALARM SYSTEM TO EXISTING APARTMENT BUILDING. SCOPE INCLUDES 46 FA DEVICES, 1 FA PANEL, AND 2 COMM PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44709	17041-20001-45219	10668 N TELFAIR AVE	91331	7	207B157   610	2619018012	R1-1VL-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.26417	-118.42601	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.75 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44710	13041-20000-33808	16817 W VENTURA BLVD	91436	5	168B133   138	2259010005	C2-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Issued	12/04/2013 12:00:00 AM	ADDRESS	34.15903	-118.49931	NEW FIRE ALARM SYSTEM FOR SMALL RESTAURANT. PC FOR NEW PANEL AND DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44711	18041-10000-10483	10250 W SANTA MONICA BLVD Delta-38	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	New revision to approved landlord's plan, noted as Delta-38 (clouded on the plan) 30 Day demand reading is also submitted for MS-ELA33 and DB-ELA44. This is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44712	14041-10001-19660	1933 S BUNDY DR BLDG 3	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.0344	-118.45642	INSTALL NEW FACP,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44713	14041-20000-05314	15052 W FRIAR ST	91411	6	177B145    43	2242020011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.18551	-118.46138	Roof mounted PV system with 3KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44714	14041-20000-24880	7014 S HOOVER ST UNIT 3	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 3.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44715	17041-10000-28261	12755 W BURBANK BLVD	91607	2	174B161   182	2341018001	R1-1, RD3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.1723	-118.41137	Replace existing fire alarm and preaction panel, remove and replace (20) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44716	18041-20003-14673	4864 W MELROSE AVE	90029	13	141B193   595	5521004030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			05/22/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	06/21/2021 12:00:00 AM	ADDRESS	34.08332	-118.30647	"05-22-2019 Changes to an approved set of plan. Changes include addition of inverter battery to each floor and emergency lights power by inverter battery. Changes has been clouded as delta ""C""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44717	18041-20000-25819	22510 W BALLINGER ST	91311	12	198B101    26	2727001022	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.24321	-118.61768	Plan check for PV roof mounted system, system size: 10kW with 35 modules and1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44718	17041-20001-29588	755 N SEWARD ST	90038	4	141B185   297	5533037001	CM-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			Reviewed by Supervisor	09/27/2017 12:00:00 AM	ADDRESS	34.08506	-118.33325	Service upgrade 600 amps.  plan check for power only.  (((((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 6,314 sq. ft.Note: Building permit has been issued under 17016-10000-05469)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44719	13041-10000-31002	21900 W PLUMMER ST	91311	12	198B105    36	2746013017	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.24254	-118.60423	"PV2.Installing of solar array roof-mounted system for commercial building .Size 63 kW DC.1 inverter AE 50TX 600v PV DC INPUT. 252 modules HYUNDAI HIS_M250MG POLY.18 strings."" $0 permit fee is due to the 2012 Senate Bill No.1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44720	19041-20000-05225	6255 W SUNSET BLVD 750	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44721	17041-20000-13381	6726 N SYLMAR AVE	91405	2	180B149   129	2237003009	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			04/24/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.19294	-118.44639	Plan check for fire alarm system only. New fire alarm system for a 13-unit apartment building. 1 FACP. 78 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44722	14041-10000-10644	232 E G ST	90744	15	030B209   486	7423013035	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	33.77784	-118.25997	T24 ONLY, REMOVING HID  FIXTURES AND REPLACING WITH NEW FLORESCENT ONE. TOTAL AREA 28320 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44723	13041-10001-26064	5206 N BELLAIRE AVE	91607	2	171B161   530	2346019010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.16517	-118.40927	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44724	10041-10002-11000			8	102B201   861	6013023900	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM			PC Approved	11/04/2010 12:00:00 AM	PIN	33.97483753	-118.28627804	Change the priviously approved plan. Change the T24 and lighting. Ti in a medical clinic. Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44725	18041-20000-41956	19448 W LEMARSH ST	91324	12	204B117   341	2726017014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.25534	-118.55747	PV1.  Install 14 kW DC roof mounted grid tied PV system.  (40) modules with 9 kW and 7.6 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44726	17041-10001-23917	13573 N GLADSTONE AVE	91342	7	228B153   509	2504009010	RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.31855	-118.43852	**Fee expedite per applicantInstall new rooftop solar system 15.2 kW AC, (69) modules, (2) inverters 7.6kW each	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44727	11041-10000-13545	640 S MAIN ST	90014	9	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.04429	-118.2507	Plan check for fire alarm.  Fire alarm was originally plan checked and approved with a permit granted under PCIS# 08041-10000-17620 on August 5, 2008.  Permit has expired so new plan check is required along with a new permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44728	13041-10000-36044	936 S WALL ST STE #C	90015	14	126A211   408	5145017045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.03775	-118.2527	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 675 SQ FT. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44729	15041-20000-29058	15545 W LEMARSH ST	91345	7	204B145   477	2660002030	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.25558	-118.47114	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (2) inverters, (31) modules, and (1) solar load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44730	11041-10001-11376	1902 E MARENGO ST	90033	14	132A223    33	5201016003	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	08/12/2013 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.05756	-118.21009	SUPPL. APPLICATION FOR CHANGES TO APPOVED PLANS. THE ORIGINAL DESIGN FOR A THREE STORY BUILDING WAS CHANGED TO A TWO STORY BUILDING. SIZE AND TYPE OF SERVICE WAS NOT CHANGED.  CORE & SHELL ONLY. COMPLETE EPC WILL BE REQUIRED FOR TI. <<Plan check power and energy for core and shell, new commercial building (1st floor - retail/restaurants, 2nd & 3rd floor (REMOVED). Site in Methane Buffer Zone, no mitigation required according to methane report. Modification to seperate fire alarm system has been filed.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44731	13041-10000-27364	16933 W DEVONSHIRE ST	91344	12	204B133   147	2684012044	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.25767	-118.50128	permit to be pulled at EPC counter only. pc for energy only ONLY FOR A FUTURE LEASE SPACE. TI IN EXISTING 1900 SQ FT. RETAIL BLDG. less than 400A per applicant.TI IN previously EXIST. RETAIL BLDG.  NEW T-BAR CEILING, NEW ENTRY DOOR, NEW ROOFTOP A/C. RE SURFACE ACCESSIBLE RAMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44732	14041-20000-17570	19411 W LONDELIUS ST	91324	12	195B117   105	2783025053	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.22997	-118.55629	TENANT IMPROVEMENT TO (E) OFFICE/ WAREHOUSE. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44733	16041-10000-43841	3201 S HOOVER ST 8C1	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	Plan check power and energy for 1st time tenant.  Total area = 1,236 sq. ft.    New lighting and receptacles .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44734	15041-20002-40831	1501 W 59TH PL	90047	8	105B193   227	6002010019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM			PC Approved	04/01/2016 12:00:00 AM	ADDRESS	33.98682	-118.30255	04/01/2016 Changes to an approved set of plans. Module count has been reduced, inverter power rating has been reduced, and PV backfeed breaker has been reduced. All changes have been reflected onto the revised single-line. *****Previous Work Description*****Experdite per applicant request{{{{{Plan check for PV roof monted system. System size: 5.0 kW with 19 modules 1 inverter(5.0kW)}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44735	15041-20000-22591	7600 COURAGE WAY	91405	6	186B145  1158			South Valley				1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20862447	-118.46419283	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44736	11041-20000-09440	15030 W KESWICK ST	91405	6	186B145    20	2209035023	CM-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Finaled	08/12/2011 12:00:00 AM	ADDRESS	34.21018	-118.46022	Replace 800 amp switchboard.  Plan check for power and energy.Note: Conduit only variance under 11041-20000-09447	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44737	16041-10000-35905	10831 N ANDORA AVE	91311	12	207B105    84	2722005004	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.26698	-118.60339	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.2KWac.(60)MODULES-Q-CELLS 275W(60)OPTIMIZERS-SOLAREDGE P300(2)INVERTERS-SOLAREDGE SE7600A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44738	18041-30000-02941	100 S BARRINGTON WALK B	90049	11	135B145   554	4401006004	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.06541	-118.46942	Plan check for Title 24 only in existing space T.I. office. Total area: 744 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44739	18041-20000-10859	5171 W WASHINGTON BLVD	90016	10	126B177   803	5067019043	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.04143	-118.35326	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 900 sq. ft.Note: Building application has been generated under 17016-20000-30540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44740	13041-10000-11765	13525 W VOSE ST	91405	2	183B157   322	2328033012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.19857	-118.42769	PV 1.  INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 7.84 kW. {33 MODULES: TSM-245 PA05} {CENTRAL INVERTER: SUNNY BOY 7000-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44741	18041-10000-37422	5400 S CENTRAL AVE	90011	9	108B209   582	5104016013	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	33.99375	-118.25629	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44742	13041-20001-01926	14141 W VENTURA BLVD	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	((8/6/2013: CHANGES MADE TO APPROVED SET OF PLANS. REMOVED L2 FIXTURE AND REVISED J FIXTURE FROM INCAN TO LED. RELOCATION OF SOME CIRCUITS. LOAD INCREASED.))New restaurant in shell building, full plan check. Fire alarm variance has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44743	17041-20000-36406	1840 S CENTURY PARK EAST 13, 14 th-flr	90067	14			M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.06188	-118.41473	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44744	15041-10000-35250	7843 N LANKERSHIM BLVD Commercial-Bld	91605	6	189B169   517	2310025034	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.21329	-118.38805	Full plan check for a new 2-story commercial building . the building is sharing a common underground parking with a 4-story apartment building under a same parcial site plan.  Scope includes 3000-Amp panel powered from a 5000-Amp service from the site. Core/Shell only, tenants build out will be under a separated permit.Building permit #: 15010-10000-03728Residential application #: 15041-10000-34860	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44745	18041-20000-19964	601 S FIGUEROA ST 3rd Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing high-rise building T.I. Total area: 7940 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44746	14041-20000-10887	20706 W ARCHWOOD ST	91306	3	180B109   259	2148021013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.19155	-118.58416	Roof mounted PV system with optimizer and transformerless inverter,  system size 3.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44747	17041-10000-41365	15121 W MONTE ST	91342	7	228B145   158	2502026050	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Issued	01/05/2018 12:00:00 AM	ADDRESS	34.32177	-118.46341	0$ FEE DUE TO SENATE BILL 1222.NEW ROOF MOUNTED PV SYSTEM. CONSISTS OF 55 MODULES (HYUNDAI 300W HiS-S300RG) AND 2 INVERTERS(SOLAREDGE SE6000A-US and SE7600A-US)SYSTEM SIZE IS 16.5KWdc/13.6KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44748	18041-20000-45687	4571 N CANOGA DR	91364	3	166-5A105 271	2190001001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.14989	-118.60286	Plan check for PV roof mounted system, system size: 6.8kW DC, 5.6kW AC CEC with 19 PV Modules and 1 inverter(7.6kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44749	19041-20000-28152	4567 N WILLIS AVE	91403	4	168A149   165	2264017036	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.15388	-118.45549	PV2.  Install 13.1 kW roof mounted grid tied PV system.  (36) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44750	19041-10000-43403	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/17/2022 12:00:00 AM	ADDRESS	33.94248	-118.40461	Adding (1) 600-Amp transfer switch and (1) 600-Amp Switchboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44751	12041-20000-15194	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM			PC Approved	06/29/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	T.I. to a high rise building on 11th floor, suite 1100.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44752	14041-20000-00042	1446 N NEPTUNE AVE	90744	13	036B205   929	7421027005	R1-1XL-O	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Wilmington	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	33.79231	-118.26969	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44753	09041-10001-24655	125 S SWEETZER AVE	90048		138B173   715	5511017012	R3-1-O		Wilshire	Mid City West			Electrical	Electrical	Apartment			07/20/2010 12:00:00 AM			PC Info Complete	07/20/2010 12:00:00 AM	ADDRESS	34.07359	-118.37026	Suppl Plan Check for changes to approved plans for changing to AL conductors and applying the Temp Derating Factor and UFER to Ground Rod.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44754	14041-20000-19206	14417 W CLYMER ST	91345	7	207B149   406	2617010010	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.2643	-118.44706	Standard Plan: 9.18KW PV1 roof-mounted system with (36) Trina Solar TSM 255PA and (2) Power One Aurora PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44755	14041-10001-14943	2576 N CORDELIA ROAD	90049	11	141B133    80	4492024005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/21/2014 12:00:00 AM	ADDRESS	34.08398	-118.50641	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 10.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44756	15041-10000-11830	5220 W HOLLYWOOD BLVD	90027	13	148-5A195  95	5544016011	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.10161	-118.30399	REMODELED TENANT SPACEPLAN CHK IS FOR TITLE 24 (see comment)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44757	14041-20000-31475	3071 N CHADWICK DR	90032	14	141A235    67	5218005041	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.08139	-118.17246	PV1Install a roof-mounted solar array on a SFD. Interconnect with 225 MSP.System size: 8.6kW. Ungrounded system.(40) EnPhase M215-IG microinverters with (40) 250W pv modules across 3 strings (15+11+14).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44758	19041-30000-45366	12751 W MILLENNIUM 5-145	90094	11	102B161  1235	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Issued	03/06/2020 12:00:00 AM	ADDRESS	33.9761	-118.41651	FULL PC FOR A TI (FIRST TIME), SCOPE OF WORK IS ADDING TWO NEW PANELS TO AN EXISITNG 2000A SWITCHBOARD (120/208 3P,4W). TOTAL AFFECTED AREA IS 2389 SQFT. ((B#18016-70001-41269))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44759	17041-20000-02507	11407 N KISMET AVE	91342	7	213B169   858	2530010010	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.27734	-118.38378	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44760	13041-10000-01975	234 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Apartment			01/25/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.05578	-118.25359	Upgrading fire alarm system for 19 story apartment building. Panels: 3 Devices: 805	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44761	13041-20000-14964	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	T24 FOR EXISTING RETAIL SPACE. SCOPE OF WORK IN THE BATHROOM AND STORAGE ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44762	15041-20003-15771	2248 N PANORAMA TER	90039	4	148-5A205 358	5432025014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.10023	-118.2696	04-20-2016 changes to approved set of plans. changes to the roof layout. 04-14-2016 Changes to an approved set of plans. Changes have been made to the PV module layout and the meter socket has been removed, as it is no longer required.*****Previous Work Description*****Changes to an approved set of plans. Changes are only to the PV modules layout.*****Previous Work Description*****Plan check for PV roof monted system. System size: 3.6kW with 17 modules and 17 microinverters connected to 200A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44763	10041-10000-09206	13337 W BEACH AVE	90292	11	108B153  1428	4230008059	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Public Safety Only			05/17/2010 12:00:00 AM	05/17/2010 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	33.99215	-118.44294	NEW FIRE WARNING SYSTEM  FOR LOFTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44764	19041-20000-00592	5049 N GLORIA AVE	91436	5	171B141   528	2261017011	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.16112	-118.47947	Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWdc/13.48 kWac-CEC and consists of (42) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44765	16041-10001-26109	21051 W SHERMAN WAY	91303	3	186B105   870	2112019002	[Q]C2-1VL-CDO, [Q]P-1VL-CDO, [Q]R3-1-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	34.20125	-118.59216	PC only. Changes under clouded area per inpector corrections. Pharmacy TI, title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44766	16041-10000-18631	11507 W PICO BLVD	90064	11	123B153   453	4260026001	[Q]CM-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.03332	-118.4429	COMMERCIAL KITCHEN. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44767	12041-10000-11352	12050 W VENTURA BLVD C201	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.14349	-118.39426	T.I. to an existing low-rise office building, suite C201.  Load is 277A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44768	18041-10000-21979	2049 S CENTURY PARK EAST Suite#1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN AN EXISTING OFFICE AREA IN SUITE #1940 ON THE 19TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44769	18041-20000-43768	5555 W MELROSE AVE Bldg 213	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Distribution replacement for movie studio.  Medium voltage equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44770	13041-10001-25331	8857 N GERALD AVE	91343	12	195B137   405	2688040001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.23182	-118.49495	[]][][EXPEDITE PER APPLICANT REQUEST ][][]PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION IN A SINGLE-STORY HOUSE. SYSTEM SIZE IS 10KW DC IN 2 STRING. DERATING 200A EXISTING MAIN BREAKER TO A NEW 175A BREAKER. (40) MODULES: REC SOLAR REC250PE(2) INVERTERS: SUNNYBOY SB7000US(240V) , SUNNYBOY SB3000HFUS-30(240V)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44771	13041-20000-31373	8742 N HANNA AVE	91304	12	195B105   169	2010009007	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.2297	-118.604	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 5.18KWAC. 24 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44772	18041-10000-09473	10250 W SANTA MONICA BLVD #1987	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant ""7 for all Mankind"" suite 1987 in Westfield Century City. Install (1) new panel, and (1) 75 kVA xfrm. New lights and powers. Total area: 1,170 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44773	18041-20001-22593	10650 N DE SOTO AVE	91311	12	207B109   345	2706011001	(T)(Q)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM	ADDRESS	34.26388	-118.58835	Revisions to approved set.  Addition of site lighting to project scope. (((Plan check for power and energy new West Valley Chrstina Church 600A Service over 100 occupant load  with associated load. Total area; 7288 sq ft B#16010-20000-06270)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44774	17041-20001-09874	12601 W PIERCE ST BLDG 43	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44775	15041-10000-38777	423 W E ST	90744	15	030B205  1071	7418002013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Closed	05/19/2017 12:00:00 AM	ADDRESS	33.77548	-118.26697	PV1 SFD. TOTAL SYSTEM SIZE 3.87KW AC USING MICROINVERTER SYSTEM. SYSTEM USES 18 MODULES IN TOTAL. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44776	13041-20000-01409	15141 W PLUMMER ST	91343	7	198B145    11	2656008012	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.24289	-118.46242	Photovoltaic system on roof of single family dwelling using Enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44777	13041-10000-13164	1431 E 110TH ST	90059	15	088-5A211 283	6070004900	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	33.93592	-118.24921	109TH STREET POOL & BATHHOUSE PROJECT.PLAN CHECK FOR POWER AND TITLE 24 AND EMERGENCY LIGHTING. 5114 SQ FEET OF INDOOR AND OUTDOOR LIGHTING. SCOPE OF WORK < 400A. ON-GOING PROJECT PLAN CHECK NUMBERS 13041-10000-01989, 13041-10000-09774.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44778	16041-20000-29507	10000 N RESEDA BLVD	91324	12	204B125   340	2731024141	(Q)RD3-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Expired	10/01/2018 12:00:00 AM	PIN	34.25201161	-118.5349199	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (10) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44779	16041-10000-41480	12975 W JEFFERSON BLVD	90066	11	102B157    93	4211008026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Closed	05/19/2017 12:00:00 AM	ADDRESS	33.97533	-118.42387	NEW 1000A DISTRIBUTION TO RELOCATE EXISTING LOADS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44780	16041-10000-42807	500 WORLD WAY T5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	TI for existing airport Terminal 5; installing new lights and receptacles. PC for T24 only for total area 12205 sqft. Applicant providing multiple T24 forms for different airline spaces within T5. Building Permit under 16016-10000-27231.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44781	14041-10001-15262	240 W ADAMS BLVD	90007	9	121-5A205 201	5122013015	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			PC Approved	08/28/2015 12:00:00 AM	ADDRESS	34.02619	-118.27205	Change to approved set by modifying the lighting plan and relocating circuits on the floor plan. All changes are under delta-4 only.(((PLAN CHECK FOR  POWER AND ENERGY. T.I. CHANGING FROM RESTURANT TO SEVEN ELEVEN STRE. NEW 400  A SERVICE,  4 NEW SUB PANELS.TAILORED METHOD.TOTAL AREA 2080 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44782	13041-10001-12061	1168 S BARRINGTON AVE	90049	11	129B145  1183	4265001039	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.0499	-118.46096	][]changes made to an approved set of plans; changes is to reflect single line diagram drawing with actual installation (subpanel 'B' is not fed via panel 'A'; Both the panels are independent. (1) additional plan check hour charged ][][]ti, NEW FIRST TIME RESTAURANT, PC FOR T24 AND POWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44783	17041-20002-44997	327 N CHESTNUT AVE	90042	14	153A233    90	5493031004	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.11489	-118.1752	PC for changes to approved set. Removing battery system and installing only 3kW(ac)/3.575kW(dc) solar system for SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44784	13041-20000-25024	735 S FIGUEROA ST #117	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	Remodel to an existing restaurant.  NOT a First-Time-Tenant per applicant.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Hi-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44785	19041-20002-34925	12134 W VIEWCREST ROAD	91604	2	162B165   830	2369008017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.13883	-118.39714	Revision to approved plans.  Additional modules, change of inverter, relocation of equipment.  Change of work description: Install 11.34 kW roof mounted PV system with 27 kWh energy storage system.  (36) modules with 10 kW rated inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44786	14041-10000-17654	4605 N LANKERSHIM BLVD 8TH & 6TH-FLS	91602	2	168B173   921	2421028013	C2-2	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.15405	-118.36832	TI IN OFFICES ON THE 6TH & 8TH FLOORS PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44787	13041-10000-15923	700 W 23RD ST 1ST FLR-2ND FLR	90007	1	123A203   124	5124029016	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.03189	-118.27706	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING FOR A CLASSROOMS AND A LABORATORY IN MOUNT ST MARY'S COLLEGE. 4115 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44788	12041-10000-05733	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.05436	-118.25543	RENOVATION OF EXISTING BALLROOMS, NEW MEETING FACILITIES, BOARD ROOM, GUEST RESTROOMS, BUSINESS CNTR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44789	13041-10002-25627	8506 S OSAGE AVE	90045	11	096B173    97	4127024025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	33.96089	-118.37861	Change to existing approve set. Replace 8 fixture B with 11 fixture A. All changes apply to delta 5 only. (((permit is issued under the original application excluded the first floor under the airline stores that has to be checked aseperately.TITLE 24 PLAN CHECK ONLY. LEGALIZE PREVIOUSLY CONSTRUCKTED MEZZANINE & PLACK BRIDGE MEZZ. 2STORY . WORK IS ON BOTH FLOORS. 12342 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44790	18041-10000-48144	2430 E PORTER ST	90021	14	121-5A217 295	5168029024	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.02651	-118.22916	INSTALLING 72 NEW FIRE ALARM DEVICES WITH 1 FIRE ALARM CONTROL PANEL FOR COMMERICAL 2 STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44791	15041-10000-38120	6747 S 5TH AVE	90043	8	102B189   784	4008013028	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Expired	12/12/2017 12:00:00 AM	ADDRESS	33.97687	-118.32273	PV1 roof mounted installation to a single family home. (21) Microinverters, total rating: 5.46 KW. (21) Modules. (1) 125 A load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44792	16041-10001-39671	14500 W OLIVE VIEW DR 1-100	91342	7	228B149    20	2502024024	QRD1.5-1, RD1.5-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	Apartment			11/08/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.32399	-118.44867	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. <<<PV, INSTALLATION OF 13.26 KW DC/12 KW AC ROOF-MOUNTED ON A PARTMENT BUILDING.(52) MODULES: CS6P255P-1-SMA(2) INVERTERS: SB7000US-12& 5000US-12>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44793	16041-10000-05419	1327-1335 1/2 S ABBOT KINNEY BLVD	90291	11	108B145  1227	4239027009	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	33.99105	-118.46709	PC FOR 800A SERVICE UPGRADE. RECONNECT EXISTING TENANTS TO NEW SERVICE. TENANT PANELS BEING UPGRADED FOR NEW SERIES RATING SYSTEM. PC FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44794	13041-10000-01584	2079 E 15TH ST	90021	14	120A217    90	5167016024	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.02214	-118.23341	Investigation fee due.  3 story nwe TI for Commercial building with 119 units with 1 house panel. 3000A Service. In a Methane Zone. SCOPE OF WORK INCLUDES NEW WIRING. IS SUBJECT TO INVESTIAGATION FEE. REFER TO CASE NUMBER 203496. FEE HAS BEEN PAID UNDER THIS APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44795	10041-10000-25780	940 W HARRY BRIDGES BLVD	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Public Safety Only			12/29/2010 12:00:00 AM			Corrections Issued	02/14/2011 12:00:00 AM	PIN	33.77046453	-118.27163726	FIRE ALARM SYSTEM FOR NEW GUARD HOUSE FOR PORT OF LA. EPC IS FOR POWER   (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44796	12041-20000-16270	7850 N HASKELL AVE	91406	6	189B141   186	2206001017	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM			PC Approved	07/13/2012 12:00:00 AM	ADDRESS	34.21333	-118.47474	T-24 lighting plan check for remodeled spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44797	16041-10000-32980	5959 W FRANKLIN AVE	90068	4	150A191   161	5586014027	R3-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			09/16/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Issued	10/05/2016 12:00:00 AM	PIN	34.1055012	-118.31956142	PC for T24 only for TI for existing apartment. Alterations to be on basement of apartment unit with 2208 sqft of space. Installing new lights and receptacles. No emergency lighting to be altered in corridor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44798	13041-20000-35601	5318 S MAIN ST	90011	9	108B205   413	5101012035	C2-1VL	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	PIN	33.99371778	-118.27357871	PC FOR T24 ENERGY ONLY. TOTAL AREA 20000 SQ FT. NEW LIGHTING. GROCERY SALES AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44799	18041-10000-37037	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	TI IN AN EXISTING WAREHOUSE. FULL PLAN CHECK FOR POWER AND ENERGY. 198,000 SQR FT. (Check Fees)BUILDING PERMIT: 18016-10000-31121	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44800	11041-10001-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	33.94386	-118.4047	MODIFICATION OF PREVIOUSLY APPROVED SET OF PLANS.  NEW EQUIPMENT, CIRCUITS AND PANELS.  CHANGES TO LOADS, FEEDERS  <<<<<core and shell plan review for the central utility plant at LAX airport>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44801	16041-10000-00208	15728 W LABRADOR ST	91343	12	201B141   262	2671005011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.24907	-118.47485	PV1. NEW ROOF MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 6.0KW-AC(18)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB # PVI-6000-OUTD-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44802	15041-20000-22571	15203 FRED WAY	91405	6	186B145  1129		(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	PIN	34.20923864	-118.46418684	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44803	14041-20000-24685	12205 W VENTURA BLVD	91604	2	162B165   117	2367017007	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.14344	-118.39864	TI to (E) commercial single-story retail building.  Plan check for energy only under 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44804	16041-10000-19583	535 W 91ST ST	90044	8	094-5A201  57	6038007041	RD5-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM			Corrections Issued	06/03/2016 12:00:00 AM	ADDRESS	33.95429	-118.28378	PV1.NEW SOLAR ARRAY ON EXISTING RESIDENTIAL ROOF-TOP. THIS IS AN ADDITION TO EXISTING PV SYSTEM. NEW 4.2KWac INVERTER WITH NEW SUBPANEL. RECONNECT EXISTING SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS  8.2KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44805	19041-20000-20738	17276 W WESTBURY DR	91344	12	219B133   287	2608016031	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.29811	-118.50972	PV 1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.88KW DC/10.756KW AC CEC/10.395KW AC. SCOPE OF WORK INCLUDES (33) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND A NEW 100A PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44806	18041-10003-38075	12616 W SHERMAN WAY	91605	2	183B161    62	2324020034	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM			PC Approved	08/05/2019 12:00:00 AM	ADDRESS	34.20097	-118.40799	"SUPPLEMENTAL CHANGES TO APPROVED SET DELTA ""D"" ONLY. CHANGES INCLUDE ADJUATING THE FIXTURE WATTAGE, T24 HAS BEEN UPDATED ACCORDINGLY. PC only<<<Tenant Improvement to existing Restaurant (Interior and Exterior). T-24 ONLY. BLDG PERMIT: 18016-10000-27310>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44807	17041-10000-32396	7950 W SUNSET BLVD SPACE C	90046	4	147B177  1021	5554003055	(Q)RAS4-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.09777	-118.36322	Plan check for T24 only, T.I. of ( e ) restaurant remodel kitchen & dining areas, 3531 sf.  Reusing existing panels and some circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44808	16041-10000-38606	4730 N CRYSTAL SPRINGS DR	90027	4	159B201    22	5593002906	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.13245	-118.28047	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTROOM SPACE. TOTAL AFFECTED IS 354 SQ. FT. B#15016-20000-09383 PONY TRAIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44809	15041-20000-15566	2011 E ZONAL AVE Room 100	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for power and Title-24 (energy).  Total area = 2,051 sq. ft.  Remodeling existing lecture hall (occupant load = 94 fixed seats) including replaced lighting and addition of power to seating area.  Remodeling restroom area for ADA compliance.Project is located in USC's HMR Bldg on the 1st floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44810	17041-10001-38944	1508 N LACHMAN LANE	90272		135B121    50	4420035004							Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			PC Approved	03/08/2018 12:00:00 AM	ADDRESS	34.06302	-118.54979	EXPEDITED FEES PER APPLICANT.PV1, SOLAR ROOF MOUNTED SYSTEM USING TWO CENTRAL INVERTERS AND TWO TESLA BATTERIES. (43) MODULES, (1) 5.2 INVERTER (1) 6.6 INVERTER, LOAD CENTER AND (2) BATTERY STORAGE.   TOTAL PV SYSTEM IS 11.8KVA  AND BATTERY SYSTEM IS 11.6KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44811	13041-10000-31374	3837 W BRUNSWICK AVE	90039	13	156A207   173	5435011024	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.12225	-118.26318	PV1. ROOFMOUNTED SOLAR ARRAY. STANDARD MICROINVERTER PLAN. (9) TRINA SOLAR MODULES(9) ENPHASE 215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44812	16041-10000-39250	1260 N VINE ST	90038	13	144B189   143	5534001400	C2-1-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.09406	-118.32645	PC for energy only. TI on existing restaurant space (Pollo Loco store #5386). Adding new indoor and outdoor lighting. Total sqft=5130.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44813	19041-10002-07680	14806 W CANTARA ST	91402	6	192B149   581	2210004014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	34.21923	-118.45577	Supplement to PV1 SYSTEM. change marked delta 1 and includes upgrading the main panel only from 125A to 225A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44814	15041-10000-15378	2242 1/2 W FAIR PARK AVE	90041	14	160-5A221  18	5686020017	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	PIN	34.13628316	-118.21648709	TI TO AN (E) OFFICE, COMPLETE RENOVATIONS INCLUDING ALL ELECTRICAL EQUIPMENT,  ORTHODONTICS CENTER.  FULL PC, PC FOR ENERGY AND POWER. TOTAL SQ. FT. 1821 .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44815	19041-10000-16581	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Closed	04/03/2023 12:00:00 AM	ADDRESS	34.18684	-118.3977	Plan check for a fire system with (1) fire alarm control panel, (1) power supply panel, and (60) fire alarm devices located in a (2) story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44816	19041-10000-11348	1841 E 50TH ST	90058	9	111A215    18	5106027003	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	33.99813	-118.23986	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44817	11041-10000-17470	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.06191	-118.41691	T.I.  Tenant currently occupies floors 19-22 but are including floor 18.  All of the 18th floor is being redesigned to meet the tenants needs.  They are also doing some minor modifications to the 22nd floor, rooms number 2268 and 2270 along with the corridor.  Applicant has requested a full plan check.  A fire alarm variance is on file to separate the fire alarm application from this application.NOTE TO PLAN CHECKER:   Applicant brought a pre-printed check.  Adjustments were made to the counts to meet the applicants needs.  Verify the counts during the plan cehck process.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44818	10041-20000-20007	7060 W HOLLYWOOD BLVD 6th floor	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	T.I. existing high rise building at office space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44819	16041-10000-31395	630 S BROADWAY	90014	14	129A211   238	5144002026	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.04581	-118.25257	PC FOR ENERGY. CONVERT PORTION OF (E) OFFICE IN THE BASEMENT TO KITCHEN . TOTAL AREA 686 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44820	15041-20000-00942	12751 W MILLENNIUM BLDG B-145	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Issued	03/09/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	BEAUTY SALON. NEW LIGHTING. TI TO EXISTING TENANT SPACE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44821	19041-10000-30195	9425 W SIERRA MAR PL	90069	4	147B165   520	4392018038	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.09605	-118.39541	Permit fee is $0.00 due to Assembly Bill 1414(ePlan) PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 36 MODULES USING P400 OPTIMIZERS AND 2 ESS(TESLA POWERWALL).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44822	13041-10000-26398	2800 S GRAYSON AVE	90291	11	105A147     9	4227023002	R1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	33.9836	-118.46306	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 2.5 KW DC ON non-standard plan IN A 2-story  HOME. power optimizers ARE  UTILIZED. UNGROUNDED SYSTEM.(10) MODULES: TRINASOLAR TSM-250PA05.18(1) INVERTER: SOLAREDGE #SE3000A-US(10)OP250-LV-MC4SM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44823	13041-10000-32474	2920 W SUNSET BLVD	90026	13	142-5A203 430	5426020013	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM			PC Approved	11/20/2013 12:00:00 AM	ADDRESS	34.08317	-118.27382	TITLE 24 PART 6 ENERGY FOR SINGLE STORY COMMERCIAL BUILDING(OFFICES) ; LIGHTING IS FOR INDOOR AND OUTDOOR, TOTALING TO 1562+2225+420 = 4207 SQ FT. SCOPE OF WORK < 400A. e-permit to be pulled @ electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44824	16041-20000-40102	8435 N ORION AVE 1-24	91343	6	192B141   304	2654029033	(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.22384	-118.47239	Plan check for new fire alarm system for 4-story, 24 unit apartment building. (1) FACP. (119) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44825	19041-10000-45202	2375 W AVENUE 33	90065	1	151-5A217 236	5456003033	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.10927	-118.23342	plan check for pv-1. system size 4340W, system includes 14 modules with Enphase microinverts and 1 -125A load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44826	14041-10000-12529	14629 W HAMLIN ST	91411	6	180B149   566	2236014018	R1-1-HPOZ	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.18884	-118.4519	PV1, INSTALL 8.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER WITH OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44827	18041-10000-15315	355 S GRAND AVE 19TH FLR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR TITLE 24 ONLY . CORRIDORS AND ELEVATORS LOBBY - TOTAL AFFECTED AREA = 1367 SQ. FT.   building permit # 17016-10000-35282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44828	17041-30000-08458	6050 W JEFFERSON BLVD	90016	10	117B169     7	4204008011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		7025.02	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.02066	-118.38059	Plan check for power and energy. Project site is a new 1-story commercial building. Project scope is the core-and-shell. Total lighting area = 21,345 sq. ft.Note: Building application has been generated under 17014-10000-01022	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44829	18041-10001-24215	3800 N LATROBE ST	90031	1	144A227   134	5304016041	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.09015	-118.19726	EXPEDITE PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44830	15041-10000-36522	434 W 112TH ST	90061	8	087A201   429	6075028035	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	33.93277	-118.28176	PVI, INSTALL 2.12 KEW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(8) MODULES: SUN EDISON SE-F265KZD-3Y(8) MICROINVERTER: ENPHAE ENERGY M215-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44831	18041-10000-47065	1533 N SCHRADER BLVD	90028	13	147A187    32	5547018901	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.09901	-118.33257	INSTALLING FIRE ALARM SYSTEM FOR SHELTER WITH 67 DEVICES, (1) FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44832	19041-10000-36426	140-144 S LINCOLN BLVD	90291	11	111B145   505	4243012008	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	10/05/2020 12:00:00 AM	ADDRESS	34.00198	-118.46882	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT IN EXISTING 3-UNIT COMMERCIAL RETAIL  SPACE.  COMBINE INTO ONE - TOTAL AFFECTED AREA = 2495 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44833	15041-30001-33053	9254 N WINNETKA AVE BLDG C	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Closed	08/10/2021 12:00:00 AM	ADDRESS	34.23884	-118.57087	03/20/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Significant changes have been made the single-line diagram due to a change in the LADWP service voltage class and size; unit substation has been removed and replaced with LADWP vault. Unit count has been reduced from 188 to 186. Every unit has had an addition of (2) circuits: electric range and electric dryer. Unit feeders have been upsized to accomodate additional load. Additional car chargers have been installed. Note: Building application for changes is found under 15010-10005-02015	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44834	15041-10000-03258	13274 W FIJI WAY 5th & 6th-floor	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	33.97902	-118.43558	Plan check for Title 24 only. Project is lighting on the 5th and 6th floors of a 6-floor building. Total lighting area = 17,220 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44835	19041-10000-09649	13171 N TELFAIR AVE	91342	7	225B141  1501	2604002052	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.31032	-118.47927	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44836	16041-10000-29879	5401 S FIGUEROA ST	90037	9	108B201  1379	5001024034	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	33.99309	-118.28287	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 11685 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44837	14041-20000-03778	4711 N BIZET PL PV1	91364	3	168B097   402	2074027037	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.15671	-118.62665	PV1, ROOF-MOUNTED SOLAR INSTALLATION 10.25 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS. *****ZERO FEES DUE TO 2012 SENATE BILL NO. 1222*****	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44838	17041-20000-01908	18415 W ALGIERS ST	91326	12	213B125   595	2870012013	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.27694	-118.53543	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (40) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44839	17041-10000-24243	2349 S CLOVERDALE AVE	90016	10	123B177   403	5063008055	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.03551	-118.35629	PC FOR PV SYSTEM 3.8KW AC USING CENTRAL INVERTER AND 16 MODULES WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44840	16041-10000-44937	3559 W CASITAS AVE LOT 5	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12083	-118.25716	Plan check for Power 11 buildings SFD live work  2 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Building 5 of 11Note: Master Application Lot 5 type B,  16041-10000-44929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44841	15041-20000-40122	4365 S PURDUE AVE	90066	11	111B161   320	4217006021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.00124	-118.41377	Plan check for PV roof mounted system. System size: 5.3kWdc/5.0kWac with 20 modules and 1 inverter. Note: Applicant request for back room plan check.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44842	17041-10001-08129	10250 W SANTA MONICA BLVD #1890	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM			PC Approved	07/27/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1ST REVISION TO APPROVED PLAN FOR FIRST TIME TI ""CHAN LUU""  IN WESTFIELD CENTURY CITY. SUITE 1890. SCOPE INCLUDES: (1) INCREASE MAIN BREAKER IN LANDLORD'S DIST.BOARD FROM 50A TO 200A, (2) ADD FUSE DISC.SWITCH FOR XFMR PRIMARY PROTECTION, (3) REMOVE SOME LIGHTING FIXTURES, (4) UPDATE LIGHTING FLOOR PLAN AND T24 FORMS RESPECTIVELY, ALL CHANGES NOTED UNDER DELTA-3*This is plan check only, permit is covered under master plan"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44843	17041-20001-25988	10947 W BURBANK BLVD	91601	2	174B173   918	2415005038	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.17232	-118.36962	Expanded scope of work relative to previous permit.  Replacement of (2) subpanels.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44844	13041-10000-21384	900 N ALAMEDA ST PHASE- 3	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.05855	-118.23671	TENANT IMPROVEMENT TO A COMPUTER ROOM #CR3. POWER PLAN CHECK. TOTAL 4 FLOOR, WORK DONE IS ON THE THIRD FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44845	10041-20000-19911	8635 W 3RD ST Suite 355W	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.07373	-118.38073	T.I. to existing building in scanning room (Cardiac Imaging).  Install general lighting and one scanning equipment.  Plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44846	17041-10001-28944	1260 N PIEDRA MORADA DR	90272	11	135B121     6	4431033003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.07002	-118.55144	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44847	15041-10001-22844	4300 N ARCOLA AVE	91602	4	165B177   697	2424023008	RE11-1-H-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/30/2015 12:00:00 AM	ADDRESS	34.14805	-118.35489	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 25.01 KW DC ROOF-MOUNTED SOLAR ARRAY ON COMMERCIAL BUILDING.(82) MODULES:LG 305NIC-B3(82) INVERTER: ENPHASE M250-60-2LL-52X>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44848	16041-20000-34776	7638 N MINSTREL AVE	91304	12	186B097   104	2014017003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.20949	-118.62449	PV1.  Install 7.8 kW DC roof mounted grid-tied PV system.  (26) modules with (1) 6 kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44849	11041-20000-03559	300 W WORLD WAY TERMINAL-3	90045	11	090B165   187	4129027902	M3-1	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	"Plan check for T24 Energy for new ""meet and greet"" area in LAX Terminal 3"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44850	18041-10000-15970	2433 N BIRKDALE ST	90031	13	144B213   118	5445003039	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	11/16/2020 12:00:00 AM	ADDRESS	34.09369	-118.23776	PC FOR  a change OF USE FROM WAREHOUSE TO OFFICE FOR POWER AND ENERGY. SCOPE INCLUDES NEW ELECTRICAL SERVICE RATED 1200A 120/208V 3PH WITH NEW SUBPANELS AND EQUIPMENT. WORK IS FOR THE CORE/SHELL ONLY AND INCLUDES MINIMAL POWER AND LIGHTING. TOTAL AFFECTED 38327 SQ.FT INDOOR AND OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44851	10041-20000-04144	1761 N VERMONT AVE	90027	4	147B197    60	5589028029	C4-1D	Central	Hollywood	Greater Griffith Park		1891.00, 1892.00	Electrical	Electrical	Commercial			03/08/2010 12:00:00 AM	03/10/2010 12:00:00 AM		Permit Finaled	12/27/2010 12:00:00 AM	ADDRESS	34.10305	-118.29205	T.I WORK IN RESTAURANT.  THIS PLAN CHECK IS ONLY FOR TITLE 24 ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44852	14041-20000-17755	333 S GRAND AVE 53rd Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Issued	07/02/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	T.I. to existing high rise building on the entire 53rd floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44853	16041-20000-16967	6922 W HOLLYWOOD BLVD #950	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.10137	-118.34103	Plan check Title 24 only in existing building T.I.. Total area: 2,806 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44854	17041-10000-02678	1365 N AVALON BLVD	90744	15	036B205  1174	7420007035	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Issued	03/15/2017 12:00:00 AM	ADDRESS	33.79064	-118.26347	PC for T-24 for TI retail space with 3067 sqft indoor and 2192 sqft hardscape. This is a rehab project from 2008. CEIS case number  239691. Building permit filed in 2015.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44855	16041-10000-44506	8001 W BEVERLY BLVD	90048	5	138B177   388	5527034023	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			Reviewed by Supervisor	12/27/2016 12:00:00 AM	ADDRESS	34.07626	-118.36389	PC FOR POWER AND ENERGY. NEW 3 STORY OVER PARKING GARAGE. NEW 3000A SERVICE, BACK UP GENERATOR AND CORE AND SHELL DISTRIBUTION EQUIPMENT. FUTURE OFFICE AND CAFE SPACES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44856	18041-10000-31586	1141 N MOHAWK ST	90026	13	141A207   388	5402031007	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1956.00	Electrical	Electrical	Apartment			08/20/2018 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	12/16/2020 12:00:00 AM	ADDRESS	34.07874	-118.26515	FULL PC FOR POWER AND ENERGY FOR A NEW 3 STORY 10 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW 600A120/240 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND CIRCUITS(2 DIFFERENT TYPES OF DWELLING UNITS). TOTAL AFFECTED AREA IS 10347 SQ. FT. B#17010-30000-01197	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44857	16041-20000-28705	20750 W VENTURA BLVD	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.16638	-118.58506	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOMS. 490SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44858	16041-20000-11843	5711 N SEPULVEDA BLVD	91411	4	174B145   884	2260010017	CM-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.17435	-118.4665	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 123,212 sq. ft.Note: Building application has been created under 16016-20000-06989	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44859	12041-20000-18094	512 E ROSE AVE D	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	New Beauty Salon, First-Time-Tenant.  Full Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44860	19041-10001-26104	7437 N VANTAGE AVE	91605	2	186B165   465	2307025040	(Q)RZ3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.20584	-118.39816	PC only revision to an approved plan, panel downsized from 200A to 125A change under delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44861	14041-20001-10082	8926 W RIDERWOOD DR	91040	7	207B189   373	2547028023	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM			Reviewed by Supervisor	05/02/2014 12:00:00 AM	ADDRESS	34.26541	-118.32644	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44862	15041-10000-35823	2601 W COLORADO BLVD	90041	14	163-5A219 158	5682010011	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.14243	-118.22314	830 SQ.FT. TENANT IMPROVEMENT IN EXISTING commercial spaceplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44863	13041-20000-35747	944 N AIROLE WAY	90077	5	144B149   302	4369026017	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/19/2016 12:00:00 AM		Issued	07/19/2016 12:00:00 AM	ADDRESS	34.08777	-118.45189	New 2-story, 96k+ sq. ft.  single family residence with 2000 amp, 3-phase service.  Plan check for power only.Electrical permit issued under 13041-20000-35747.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44864	17041-20001-19256	4200 N RADFORD AVE BASEMENT	91604	2	165B169   370	2368001028	[Q]MR2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	34.14736	-118.39192	Revisions to approved set of plans.  Relocating connection point of 80 kVA UPS from one distribution board to another in the same equipment room.(((UPS module replacements in (E) commercial facility.  (3) 300 kVA UPS modules and (1) 80 kVA module.  New paralleling switchboard.  Plan check for power.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44865	18041-20001-02118	11051 W CALIFA ST	91601	2	177B173  1419	2337021014	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.03	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	34.17771	-118.3721	Expedited plan check fee.PV1.  Install 12.60 kW DC//11.2 kW AC roof mounted grid tied PV system.  (35) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44866	16041-10000-42008	12241 W WILSHIRE BLVD	90025	11	126B145   294	4264026001	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.04298	-118.46913	Plan check for Title 24 only in existing building for veterinary clinic. Total area: 2,995 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44867	18041-10000-30196	1934 S WESTHOLME AVE	90025	5	129B157   318	4317005009	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	11/17/2018 12:00:00 AM	ADDRESS	34.05187	-118.42711	NEW ROOF MOUNTED 3800 W(DC) PV SYSTEM WITH 14 PV MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44868	17041-10001-25142	1101 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   147	5037025019	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Apartment			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.01106	-118.29422	CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE OF CHANGE INCLUDES 3RPS AND 14 DEVICES (DUCT DETECTOR).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44869	16041-10000-38740	11845 W OLYMPIC BLVD #840	90064	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Issued	11/01/2016 12:00:00 AM	ADDRESS	34.03291	-118.45177	PC GOR ENERGY. TI. OFFICE TOTAL AREA 5625 SQ. B # 16016-10000-22501	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44870	17041-10000-29684	3407 E 4TH ST	90063	14	124-5A227 346	5179013041	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2039.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Expired	09/26/2023 12:00:00 AM	ADDRESS	34.03397	-118.19652	PC FOR SFD PV SYSTEM. TOTAL SIZE 3.8KW AC USING CENTRAL INVERTER WITH 14 MODULES, USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44871	19041-20000-32069	20811 W ACORN CIR UNIT #168	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.29455	-118.58701	Plan check for PV roof mounted system, System size: 3.15KW with 9 PV Modules and 9 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44872	19041-20000-10170	10043 N COMMERCE AVE	91042	7	202-5A199  27	2568008018	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.25146	-118.28879	T24 PLAN CHECK FOR NEW ONE STORY COMMERCIAL OFFICE/STORAGE BUILDING. INSTALLING LIGHTS, OUTLETS, AND NEW 200A SERVICE WITH 200A BUS MDP, AND 200A SUB PANEL. TOTAL SQUARE FOOTAGE = 1654 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44873	19041-20000-25228	295 W 8TH ST 275-295	90731	15	015B201   304	7455023027	RD1.5-1LD	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	33.73677	-118.28338	MULTIPLE SINGLE FAMILY DWELLINGS WITH ATTACHED 2-CAR GARAGE, 800 AMP 120/240, 1PH. LOT 1 - 12. Building A BLD#: 17010-20000-03201	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44874	16041-10000-32665	777 S ALAMEDA ST 2ND FLR	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.03396	-118.24117	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE ON THE 2ND FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 20140 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44875	17041-10000-31201	6555 W BARTON AVE STE 100	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.08785	-118.33475	PC FOR T24 ENERGY ONLY. OFFICE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44876	19041-20000-50890	3022 N ROSCOMARE ROAD	90077	5	159B145   596	4378007001	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Closed	07/23/2022 12:00:00 AM	ADDRESS	34.12877	-118.46776	Plan check for PV roof mounted system, PV system size: 7.56KW with 24 PV Moduels and 1 inverter and 2 Energy Storage System Tesla Power Wall 2.0. Energy Storage System size: 27KWH.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44877	16041-10000-22797	60 E MARKET ST 1-4	90291	11	108A143   451	4226008007	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Issued	07/19/2016 12:00:00 AM	ADDRESS	33.98796	-118.47313	Installing a roof mounted solar system to a 4-unit apartmen unit. 12 new microinverters rated at 250 watts for a total size of 3.0 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44878	15041-20000-00587	16145 W CHASE ST	91343	12	192B141   165	2673002038	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2015 12:00:00 AM			Corrections Issued	01/21/2015 12:00:00 AM	ADDRESS	34.22484	-118.48439	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 17 MODULES IN TOTAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44879	11041-10000-00856	1040 N LAS PALMAS AVE stage 5&6	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM			PC Info Complete	03/24/2011 12:00:00 AM	ADDRESS	34.09003	-118.33615	New Pv system for a commercial building. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44880	14041-20000-34512	17168 W HALSTED ST	91325	12	201B133   572	2692018006	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.24471	-118.50842	PV1 SFD. TOTAL SYSTEM SIZE 8.6KW AC USING MICROINVERTER SYSTEM WITH ENPASE M250. USING STANDARD PLAN. TOTAL OF 36 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44881	14041-10000-02365	8404 W FRANKLIN AVE	90069	4	147B173    97	5558027009	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.09877	-118.37282	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH OPTOMIZERS. SYSTEM SIZE: 6.5KW. TWO STORY HOUSE.(26) TRINA SOLAR #TSM-250(26) SOLAREDGE OP300 OPTOMIZERS(1) SOLAR EDGE #SE6000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44882	19041-10004-03618	654 E VERNON AVE	90291	11	111B145  1229	4239003018	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	33.99767	-118.46818	Plan check only. Delta 2 changes to an approved set. Changing the layout of the solar modules on the roof. Original Scope: ((PV1 with ESS, Install 7.6 kW AC/ 6.175 kW DC roof-mounted solar array, with 13.5 kWh ESS, interconnect with 200A service panel. (19) modules, (1) 7.6 kW inverter, (1) 200A load center, (1) 13.5 kWh ESS.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44883	13041-10000-17189	4501 W COLORADO BLVD	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	Replacement of exterior lights in Baxter facility loading dock.  Relocation of existing lights and door disconnects, some new lighting load.  Title 24 plan check only, permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44884	17041-10000-39680	1077 W 38TH ST	90037	8	117B197  1265	5037015031	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Apartment			11/02/2017 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.0174	-118.29395	PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. SCOPE INCLUDES 595 FA DEVICES, AND 21 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44885	14041-10000-05456	5791 W IMPERIAL HWY BLDG B	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	33.93414	-118.3839	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO DHL EXPRESS IN LAX. LIGHTING FOR CANOPY STRUCTURE. 2927 SQFT, EMERGENCY LIGHTING. BUILDING B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44886	15041-20000-29556	4666 N FARMDALE AVE	91602	2	168B169   704	2354013038	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.1558	-118.38114	Plan check for PV roof mounted system. System size: 8.2kW with 42 modules and 1 inverter(8.2kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44887	11041-10000-08491	1900 S AVENUE OF THE STARS 15TH FLR.	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			PC Approved	04/28/2011 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI TO AN EXISTING OFFICE SPACE ON THE 15TH FLOOR.  T-24 AND EMERGENCY LIGHTING, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44888	13041-10000-26716	14612 W CHASE ST bldg c	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Info Complete	03/19/2014 12:00:00 AM	ADDRESS	34.22458	-118.45103	Core and shell for 1-story type V-B retail and restaurant.  11,349 sq ft.  BLDG C on submitted electrical plan set.  Tenanst to have their own plan check and permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44889	13041-10000-36093	2030 N CUMMINGS DR	90027	4	151-5A195 179	5589009019	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			Reviewed by Supervisor	02/04/2014 12:00:00 AM	ADDRESS	34.10803	-118.30192	PV1 ONE STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 10.0-1 KW STANDARD PLAN. [INVERTER: fronius] [SOLAR MODULE: TRINA SOLAR TSM-PC/PA05]. no fee due to 2012 senate bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44890	14041-10000-35592	5454 S CENTINELA AVE	90230	11	105B161   826	4220012021	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM			PC Approved	12/24/2014 12:00:00 AM	PIN	33.98308742	-118.41076608	Energy plan check for an office T.I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44891	19041-10000-37440	4945 1/2 E LYNN ST	90042	1	151-5A225 314	5471021014	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1851.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.10838	-118.20547	NEW 3.72KW ROOF MOUNTED PV SYSTEM WITH 12 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44892	16041-10000-27371			14	121-5A209 128	5131005014	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	PIN	34.02745331	-118.25525725	PC FOR TITLE24 ENERGY ONLY. TOTAL AREA  3213  SQFT.CONDITIONED 1476UNCONDITIONED 1737	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44893	14041-20001-36054	7232 N WHITEHALL LANE	91307	12	186B089   706	2027023044	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2014 12:00:00 AM			PC Approved	01/12/2015 12:00:00 AM	ADDRESS	34.20259	-118.65333	PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service pannel. (57) KD 200-60 modules(2) PVI-6000 TL inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44894	15041-20001-08772	17061 W LASSEN ST	91325	12	201B133   128	2694008035	(T)RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.25042	-118.50439	Plan expedite per applicant request(((PV1. Standard plan. Install roof mounted PV system size 6 kW in SFD. Interconnected with main service panel.(15) X21-345 Panels(1) SB 6000 TL Inverter))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44895	18041-10000-04506	5850 S VERMONT AVE	90044	9	105B197    72	6004001024	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Public Safety Only			02/07/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	33.98773	-118.29129	NEW (BACK BONE)  FIRE ALARM SYSTEM IN A COMMERCIAL BUILDING . IT INCLUDES IT INCLUDES TWO NOTIFICATION CIRCUITS AND MODULES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44896	16041-20000-37325	6224 W ORANGE ST	90048	5	135B177   458	5510027019	[Q]R3-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.06426	-118.36431	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44897	14041-10001-24452	1758 S CARMONA AVE	90019	10	126B177   682	5064009005	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	ADDRESS	34.0422	-118.3603	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(24) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE5000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44898	10041-10000-22939	624 S GRAND AVE	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	PIN	34.04778206	-118.25563275	NEW 5000AMP SERVICE, BUSWAYS, CABLEBUS AND SWITCH BOARD, RECONNECT EXISTING FIRE PUMP TO NEW SERVICE. PLAN CHECK IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44899	16041-10000-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	PC FOR POWER AND ENERGY for a service upgrade to 1600 amps 480/277V 3phase for wire. New equipment and circuits also added. Total sqft is  123,977	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44900	14041-20000-14483	5911 N COUNTY OAK ROAD	91367	3	177B085   566	2032026043	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.17774	-118.66767	PV1.  Install 5.28 kW roof-mounted utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44901	16041-10001-44126	10751 W RIVERSIDE DR	91602	4	165B177    46	2423001007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Mid-Town North Hollywood		1431.00	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM			PC Approved	01/20/2017 12:00:00 AM	ADDRESS	34.15241	-118.36536	PC supplemental for service change from 120/240 V 350 A single phase 3w to 120/240 V 400 A single phase 3w.  Changes under delta 1. Service change was per DWP.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44902	16041-20000-30439	7359 N KESTER AVE BLDG B-UNITS 4-6	91405	6	186B149   544	2221013005	RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.20449	-118.45765	NEW FIRE ALARM SYSTEM 2 DEVICES PLUS 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44903	15041-10000-34934	900 W OLYMPIC BLVD #51F	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			10/20/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Issued	12/22/2015 12:00:00 AM	ADDRESS	34.04526	-118.26611	PC for power to an existing highrise apartment unit (#51F). Installing new service greater than 400 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44904	14041-20000-05175	1341 N SAN REMO DR	90272	11	132B133   317	4425029001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.05436	-118.49976	PV1 SFD. TOTAL SYSTEM SIZE 9KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. TOTAL OF 36 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44905	15041-10000-11219	9813 N WOODALE AVE	91331	6	201B153   336	2645024030	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.24892	-118.43694	PV1, INSTALL 7.02 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, TIE WITH MAIN SERVI E PANEL. (27) MODULES: KYOCERA KU2606XPA, (1) INVERTER: PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44906	19041-10001-07680	14806 W CANTARA ST	91402	6	192B149   581	2210004014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM			PC Approved	03/11/2019 12:00:00 AM	ADDRESS	34.21923	-118.45577	PC ONLY. DELTA 1 CHANGES TO AN APPROVED SET. UPGRADING THE MAIN SERVICE PANEL TO 225A WITH 200A MAIN BREAKER AND RECHECK FOR LOAD SIDE CONNECTION COMPLIANCE. PANEL UPGRADE PERMIT WILL BE PULLED SEPERATELY. (((PV1 SYSTEM 3.780 KW 12 MODULES ROOF MOUNTED, RESIDENTIAL. (12) MODULES AND (1) 3.8 KW INVERTER))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44907	14041-10000-28858	2770 N ROSCOMARE ROAD	90077	5	156B145    80	4378014001	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2014 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.12538	-118.46527	Full plan check for a new single family house.  600 A service with 6 subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44908	15041-20000-21587	5327 N HERMITAGE AVE	91607	2	171B165   215	2347025013	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			07/08/2015 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.16757	-118.40046	Plan check for power and energy. Project scope is a new 4-story, 42-unit apartment building. Work includes a new 1600-amp service, (54) panels, and associated loads. Fire alarm variance has been filed.Building permit found under application number 15042-20000-13720.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44909	17041-10003-01942	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Issued	12/13/2018 12:00:00 AM	ADDRESS	34.18684	-118.3977	DELTA 10 CHANGES TO APPROVED PLAN.CHANGES INCLUDES UPDATED PANEL SCHEDULE BREAKERS, BRANCH CIRCUITS, AND LOAD FOR ESCALATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44910	17041-20000-23772	11112 W BURBANK BLVD	91601	2	174B173   990	2350003056	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			07/14/2017 12:00:00 AM			Reviewed by Supervisor	08/15/2017 12:00:00 AM	ADDRESS	34.17187	-118.37283	new apartment building 800 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44911	19041-10000-10263	351 E 15TH ST	90015	14	123A209    41	5133019011	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Issued	03/22/2019 12:00:00 AM	ADDRESS	34.03287	-118.25926	Remove HID fixture and replace with new LED fixture, T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44912	13041-20002-01926	14141 W VENTURA BLVD	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	(((changes to approved set of plans. As built set of plans. pc for delta CB2. changes include T24 , panel, and feeder loads. all to reflect installed equipment. )))((8/6/2013: CHANGES MADE TO APPROVED SET OF PLANS. REMOVED L2 FIXTURE AND REVISED J FIXTURE FROM INCAN TO LED. RELOCATION OF SOME CIRCUITS. LOAD INCREASED.))New restaurant in shell building, full plan check. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44913	13041-10000-09035	4335 S GLENCOE AVE	90292	11	105B153    56	4212004015	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	33.98632	-118.43959	pc for energy and power. place of assembly movie theater. general remodel of amc theater. removing existing generator. recalc fees and sign lighting feesRENOVATING ALL AUDITORIUMS WITH NEW SEATING, SCREENS, PROJECTORS, LIGHTING AND FINISHES THROUGHOUT; NEW PLUMBING FIXTURES, PARTITIONS AND ACCESSORIES LIGHTING AND FINISHES IN RESTROOMS; NEW EQUIPMENT, CASEWORK AND FINISHES IN <SEE COMMENTS>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44914	18041-20000-18023	5015 N FIGUEROA ST	90042	1	150A225   172	5468004008	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	02/03/2021 12:00:00 AM	ADDRESS	34.1054	-118.20178	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from auto repair/retail/office to retail/office. Scope of work is the core and shell of the building. Tenant improvement will be under separate permits.Note: Building permit has been issued under 17016-10000-11614.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44915	19041-10000-52504	16001 W STRATHERN ST	91406	6	189B141    49	2206005015	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	04/19/2021 12:00:00 AM		Issued	04/19/2021 12:00:00 AM	ADDRESS	34.21581	-118.48151	Full plan check for an office Tenant improvement. Scope work includes new 800A distribution board, three 225A panel boards, and circuits. Total effective area: 6,458 square feet. *****************************************************Expedite per application request.Energy plan check for an office T.I. Scope includes new lighting and equipment with a total lighting area of 6,458-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44916	11041-20000-12287	537 E VENEZIA AVE	90291	11	108B145  1638	4237003009	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM	06/16/2011 12:00:00 AM		Permit Finaled	08/13/2011 12:00:00 AM	ADDRESS	33.98952	-118.45973	T.I. to existing building.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44917	19041-10000-21846	1031 S DEWEY AVE	90006	1	129B197   402	5078014009	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			07/24/2019 12:00:00 AM			Reviewed by Supervisor	09/04/2019 12:00:00 AM	ADDRESS	34.05171	-118.29597	Full plan check for a new a four-story,  44-unit Apartment complex with uncovered rooftop deck over one-story, Parking Garage with one level of  Basement Parking. Scope includes a new 1200A 208/120 3-pahse service. Total affected area is 39845-SQ FT with 5-typical unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44918	15041-20001-02805	12468 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.97899	-118.41015	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44919	16041-20000-22484	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.16935	-118.53104	(N) fire alarm system for (E) parking structure.  New FACP with (14) new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44920	14041-10000-06055	11735 W HAMLIN ST Bldg. 1-Rooftop	91606	2	180B169   795	2322020066	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.18884	-118.38909	((((((((((   8-4-14 m.zandi the total numbers are broken to 3 bldgs  and bldg  1  under the same application permit and the other two bldgs under two supplmental xpress permit.)))))))))))))))           PV2, INSTALL 18.OO KW DC ROOF-MOUNTED AND ON CARPORT SOLAR ARRAY, UPGRADING 3 SUB PANELS(~100A).(4 )TRANSFORMERLESS INVERTERS:SMA AMERICA SB6000-TL-22-US & SB3800-TL-22-US & SB3000-TL-22-US. (72)MODULES: TRINA SOLAR TSM-PA05.08	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44921	13041-20000-11228	17761 W RIDGEWAY ROAD	91344	12	213B129    91	2601040037	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.28261	-118.52005	solar single family floor mount	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44922	12041-10000-02413	3650 W MARTIN LUTHER KING, JR BLVD 1st floor-passageway	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/07/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	New exit passageway in existing retail space at Baldwin Hills Crenshaw Plaza.  No suite number, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44923	19041-10000-06193	4755 N EAGLE ROCK BLVD	90041	14	159A221    35	5685016012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.13188	-118.21643	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44924	17041-10001-20599	217 S VIRGIL AVE	90004	13	135B197    83	5501020005	R3-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Apartment			08/16/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.06982	-118.28703	PC ONLY FOR PV SYSTEM ON APARTMENT BUILDING. PERMIT ALREADY ISSUED UNDER MASTER. THIS IS PC ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44925	18041-20000-18470	11050 W SANTA MONICA BLVD 2nd-3rd Floor	90025	5	129B153   810	4323019052	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04783	-118.44275	Plan check for Title 24 Energy Only in existing high-rise building 2nd and 3rd floor T.I. office space. Total area: 12,608 sq ft.B#18016-10000-15192	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44926	18041-20000-16944	16644 W ROSCOE PL	91343	12	192B137   310	2689022001	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.22118	-118.49573	Construction of an aviation fuel farm.  Hazardous classification around jet fuel tanks.  Plan check for power.Express permit previously issued under 18041-20000-16969.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44927	13041-10000-19746	2682 1/2 W MOSS AVE	90065	1	150B213   100	5457016007	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Apartment			07/25/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.11111	-118.23814	PV1 1.47 KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: POWERONE PVI-3.0-OUTD-US ] [( 6) MOD: TRINA {TSM-245PC05.18} ] 2 of 3 13041 10000 19746 (2682 1/2 moss ave)for reference:1 of 3 13041 10000 19738 (2682 moss ave)3 of 3 13041 10000 19749 (2684 moss ave)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44928	15041-10001-39995	23330 W OXNARD ST	91367	3	177B093   845	2041006017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM			PC Approved	12/28/2015 12:00:00 AM	ADDRESS	34.1777	-118.63561	Expedited plan check per customer request.  PV1. Install roof mounted PV system sized 13.65 kW. Interconnectd with main service panel.(42) SunEdison 325W Modules(42) SolarEdge Power Optimizers(1) Solar Edge SE11400A-US Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44929	15041-10000-01290	450 S WESTERN AVE	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	Renovation inside supermarket for a bakery.    Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44930	12041-10003-29911	"12722 W MILLENNIUM BLDG ""B"""	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			03/06/2015 12:00:00 AM			PC Approved	03/13/2015 12:00:00 AM	ADDRESS	33.9761	-118.41564	"((3/6/2015)) BUILDING ""B"" REVISION A TITLE 24 ONLY.  CHANGE OF FIXTURES TO LED.TITLE 24 2008 STANDARDS TO BE USED.  REVISION TO APPROVED PLANS. DELTA 10 - ADD NEW CENTRAL WATER HEATING, CIRCULATING PUMP FOR BUILDING AND REMOVE GAS WATER HEATER FOR DWELLING UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44931	19041-10000-40862	5110 N AVENIDA ORIENTE	91356	3	171B125   624	2181013009	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.16358	-118.53151	PV1. LADWP Community Solar Program: 8.00KWdc / 6.44KWac - 28 solar modules and 28 enphase IQ7-60-2-US micro-inverters. 1 service interconnected as a new service drop 100A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44932	16041-20001-42027	2132 N MAYVIEW DR	90027	4	148-5A203 322	5430008008	R1-1	Central	Hollywood	Los Feliz	Yes	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2016 12:00:00 AM			PC Approved	12/09/2016 12:00:00 AM	ADDRESS	34.10057	-118.27636	expedite per applicantpv1install roof mounted pv system with battery back up sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44933	16041-10000-44386	4278 W 3RD ST	90020	10	135B193   224	5503004011	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	ADDRESS	34.06882	-118.3076	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO EXISTING OFFICE SPACES WITHIN AN EXISTING MEDICAL BUILDING.  NO EXAMINATION (GENERAL CARE) IS BEING DONE IN THE OFFICE SPACES. TOTAL AFFECTED AREA IS 615 SQ. FT. B#16016-10000-21986	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44934	19041-20000-51142	8410 W GRAND VIEW DR	90046	4	148-5A173 146	5556021010	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	12/28/2019 12:00:00 AM	ADDRESS	34.10264	-118.37395	Plan check for PV roof mounted. PV system size: 11.34 KW with 36 PV Modules and 1 inverter(10KW) and Energy Storage System: 27KWh. 2 Tesla Power Wall 2.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44935	15041-10000-18835	547 S SEATON ST	90013	14	126A215   150	5163027010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Expired	09/26/2017 12:00:00 AM	ADDRESS	34.04008	-118.2373	Energy plan check for a warehouse; Scope includes new lighting, equipment and 400-Amp service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44936	17041-10001-19811	522 N HOOVER ST	90004	13	141A201   220	5401009050	C1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1959.03	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM			PC Approved	06/29/2017 12:00:00 AM	ADDRESS	34.08026	-118.28428	Changes to approved set.  Relocate inverter and add AC disconnect.  Add new auxillary electrode for array grounding.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44937	10041-20001-25892	5601 N DE SOTO AVE 4th floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	Delta 2 modification to previously approved set of plans.  Install one 3000 watt UPS to supply DDC panel. Supplied from circuit L42B-15.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44938	18041-20002-36214	10250 W SANTA MONICA BLVD space 2480	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Issued	02/22/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"02/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. Changes have been made to the lighting and power floor plans. New loads have been added.01/17/2019 SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, DELTA 4 CHANGES ONLY, SCOPE OF WORK INCLUDES 31 NEW DIMMABLE DRIVERS 0-10V, CHANGES TO T-24 INSTALLED WATTAGE, UPDATE TO LIGHTING FIXTURE SCHEDULE, AND UPDATE TO DRIVER LEGEND.*****Original Work Description*****PC FOR FIRST TIME TENANT FOR JEWELRY STORE ""AME"" POWER AND ENERGY IN WESTFIELD MALL. space 2480SCOPE INCLUDES NEW PANELS, EQUIPMENT CIRUCUITS AND LIGHTS. TOTAL AFFECTED AREA 1030 SQ.FT USING TAILORED METHOD. B# 18016-10000-30629"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44939	14041-10001-02365	8404 W FRANKLIN AVE	90069	4	147B173    97	5558027009	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	ADDRESS	34.09877	-118.37282	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH OPTOMIZERS. SYSTEM SIZE: 6.5KW. TWO STORY HOUSE.(26) TRINA SOLAR #TSM-250(26) SOLAREDGE OP300 OPTOMIZERS(1) SOLAR EDGE #SE6000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44940	18041-10001-36482	2748 W 8TH ST #101	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM			PC Approved	09/25/2018 12:00:00 AM	ADDRESS	34.05747	-118.28552	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 1199 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44941	18041-20001-29729	14412 W SAN JOSE ST	91345	7	207B149   745	2648021003	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM			PC Approved	10/17/2018 12:00:00 AM	ADDRESS	34.26166	-118.4475	Original standard plan from online permit lost; this supplemental is for plan check only for the system as originally permitted. (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44942	13041-20000-04388	21301 W VENTURA BLVD	91367	3	171B105    15	2167001019	(T)(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	PIN	34.16827238	-118.59592564	T-24 lighting plan check for new lighting system in existing auto service offices and shops	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44943	11041-10000-04005	7341 W WILLOUGHBY AVE	90046	5	144B181   763	5531020900	OS-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	34.08723	-118.35022	TITLE 24.  SINGLE STORY RECREATION ROOM FOR POINSETTIA RECRIATIONAL CENTER.   Permit is on application 12041-10000-00759	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44944	10041-10000-13625	13648 W VAN NUYS BLVD	91331	7	207B157  1233	2646006024	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	03/07/2012 12:00:00 AM	ADDRESS	34.26002	-118.43009	Upgrade electrical service from 400 oh to 600 amps under ground . Intercept to old service about 4 feet of STOW and 67% derating factor and remove and cover the old meterand use the panel as branch panel. Transformer and fuses provided.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44945	17041-10000-04729	314 S HARVARD BLVD	90020	10	135B193   258	5503007013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			02/13/2017 12:00:00 AM			Reviewed by Supervisor	02/21/2017 12:00:00 AM	ADDRESS	34.06844	-118.30393	Plan check for power and energy.  New 4 story 11 unit apartment building with one level of subterraniean parking.  New 800 amp 120/240 volt 3 phase delta connected service.  Project is located in a methane buffer zone.  Title 24 area = 12,968 sq. ft.Building permit #16010-10000-03822	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44946	11041-20001-11373	1411 W 190TH ST 225	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	33.85852	-118.30317	revise energy caculation change light fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44947	16041-20001-12648	1188 1/2 S MULLEN AVE	90019	10	129B185   236	5083011015	R2-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.05261	-118.3341	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44948	16041-10001-15622	2501 S WEST VIEW ST	90016	10	123B181   758	5049008056	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			Reviewed by Supervisor	05/10/2016 12:00:00 AM	ADDRESS	34.03352	-118.34817	EXPEDITE PER APPLICANT REQUEST.(((((PV2. NEW SOLAR SYSTEM SYSTEM ON EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE IS 11.4KWdc / 10.0KWac.(44)MODULES-SOLARWORLD SW 260 POLY(44)OPTIMIZERS- SOLAREDGE P300(1) INVERTER- SOLAREDGE SE10000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44949	13041-20000-11051	1947 N CAHUENGA BLVD 109-110	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.10686	-118.33085	TI OF EXISITING OFFICES. CHANGE IN LIGHTING FIXTURES TO MORE ENERGY EFFICIENT FIXTURES. TOTAL AREA 908 SQ FT. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44950	14041-10001-09167	230 W AVENUE 26	90031	1	141A221   285	5205014018	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.07911	-118.21808	REVISIONS TO PERMITTED SET OF PLANS- DELTA 13 CHANGES INCLUDES REMOVAL OF GENERATOR/TRANSFER SWITCH NEW EQUIPMENT AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44951	13041-20000-32317	2600 N SAN FERNANDO ROAD	90065	1	150B213   403	5457002009	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	PIN	34.10848267	-118.24211246	New 600 amp service.  New receptacles, panels.  No lighting will be installed.  PLAN CHECK ONLY for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44952	17041-10001-21893	4550 W PICO BLVD STE 305	90019	10	129B185  1008	5083033019	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.04842	-118.33486	12-01-2017 Changes to an approved set of plan. Changes include add new tranck lighting fixtures. Changes has been clouded as delta 4 and 6. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44953	16041-10000-29138	333 S HOPE ST 1900	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC for energy only to existing high rise building (bank of America) work being done on19th floor. Installing new lighting and power. Total sqft = 2026	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44954	19041-20000-36197	3364 E 14TH ST	90023	14	118-5A225 410	5190032002	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.01711	-118.2068	TI for commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44955	18041-10000-00658	2116 N ALTA ST	90031	1	136-5A225  76	5211008011	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.06965	-118.20376	PC for new 3.3kW solar system or SFD. Installing 10 modules with enphase microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44956	14041-10000-21397	14402 W CALIFA ST #6	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44957	19041-10002-09937	2600 S HOOVER ST BLD. A	90007	9	123A201   122	5123001900	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			10/31/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.03132	-118.2838	PLAN CHECK ONLY. Building A (10/31/19): CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATIONS OF EXISTING LOADS(INCREASE IN LOADS) WITH RELOCATION OF SERVICE. MODIFICATIONS TO LIGHTING SYSTEMS AND MODIFICATIONS OF LOADS. ALL CHANGES HAVE BEEN CLOUDED UNDER DELTA C01 (SERVICE ALTERATIONS) AND AS1 10 (LIGHTING SYSTEMS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44958	12041-10000-18343	11239 W VENTURA BLVD	91604	2	162B173   294	2366035036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.14181	-118.37523	changes to common areas  for shell and core plans-corridor, storage and restroomsPlan check is fortitle 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44959	14041-20000-21584	5750 E OMAHA ST	90042	1	150A229   179	5492006006	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.10543	-118.19066	PV1 SFD. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 14 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44960	16041-20000-39921	6865 W FOOTHILL BLVD	91042	7	202-5A201 529	2568020042	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.24792	-118.2816	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 1,450 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44961	15041-10000-16159	3827 N RANDOLPH AVE	90032	14	145-5A233 271	5306010048	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	34.09117	-118.18003	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.5KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 15042-90000-07273	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44962	18041-30000-20091	4120 W JEFFERSON BLVD	90016	10	120B181   775	5046006002	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.02541	-118.34136	Full plan check for a new office construction. Scopes include a new 600-Amp service and electrical system for core/shell preparation only. Total area for T24  is 10,000-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44963	15041-10000-10284	900 N ALAMEDA ST 1ST  floor	90012	14	133-5A215 265	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.05855	-118.23671	DISCONNECTING FEEDERS SUPPLYING  SWBDS SB1A AND SB1B AND CONNECTING FEEDERS TO THE SWBDS TO SUPPLY  TWO 480V 4000A SWBD HAVING NO LOADS  CONNECTED TO THEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44964	10041-20000-25723	25965 S NORMANDIE AVE 1st floor	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			PC Info Complete	12/28/2010 12:00:00 AM	ADDRESS	33.78734	-118.29768	Per applicant, electrical plan check for new receptacles in Pharm A108 as shown on plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44965	13041-20000-22442	11313 W WEDDINGTON ST	91601	2	171B173   290	2350016001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.16711	-118.3779	Change to lighting in an 2-story existing office building.  Load is less than 400 amps per the applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44966	12041-10000-25315	20837 W NORDHOFF ST	91311	12	198B109   172	2748037030	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.23563	-118.58754	Change of use for a new car dealership.  Load is less than 400 amps per applicant.  Change to lighting, PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44967	14041-20001-23821	4810 N BALBOA AVE	91316		168B133   256	2289019151							Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	PIN	34.15777393	-118.50295447	Expedited plan check per applicant request.  PV1.  Install 9.00 kW roof-mounted, utility-interactive PV system.  400A MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44968	19041-20000-47499	1833 S VICTORIA AVE	90019	10	126B185   876	5071003010	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.04049	-118.33227	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 9.78KWac, SCOPE OF WORK IS 24 AC MODULES (SPR-A400) WITH A SOLAR LOAD CENTER, TIEING TO THE GRID THROUGH A BACKFEED PV BREAKER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44969	19041-10000-06320	610 W 6TH ST Ground-Flr	90017	14	129A209   266	5144005125	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.04881	-118.25573	Energy plan check for a restroom and corridor T.I located in a restaurant of a high rise building. Scope includes new lighting and equipment with a total area of 172-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44970	16041-20000-12138	4700 W SUNSET BLVD PV1	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.09788	-118.29194	Plan check for a PV2 carport PV system. System size is 59 kWac and consists of (2) inverters, (260) modules, and (1) load center.Note: Building application has been created under 16014-20000-01528	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44971	15041-10000-30470	8408 W BEVERLY BLVD	90048	5	138B173   487	5511012005	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Expired	11/10/2017 12:00:00 AM	ADDRESS	34.07589	-118.37352	PC for energy only, retail pharmacy, total indoor area 1965 sq. ft. Existing  200A service. New branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44972	19041-20000-29441	625 E COLEMAN AVE 1 of 2	90042	14	148-5A231   3	5301011029	[Q]RS-1D	East Los Angeles	Northeast Los Angeles	Hermon	YES	2013.02	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.10231	-118.18265	pv3install roof mounted pv system sized 21.4KW AC interconnecte with msp.this is system 1 of 2(service 1 meter 9-162330).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
44973	13041-20000-20424	5350 N RESEDA BLVD	91356	3	171B125   104	2161018046	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Closed	02/25/2014 12:00:00 AM	ADDRESS	34.16819	-118.53619	Plan check for power and energy. Commercial change of use. HomeGoods.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44974	14041-10000-27360	7004 S RAMSGATE AVE	90045	11	102B173   427	4103014009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	33.97304	-118.37126	Solar PV roofmounted residential standard plan. # of inverters installed: 2. System size: 7.6kW (3.8kW each). # of modules: 35.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44975	18041-10001-01217	11131 W GREENLAWN AVE	90230	11	111B165    55	4215007018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.0026	-118.40275	expedite per applicant requestNEW ROOFTOP SOLAR SYSTEM, CONSIST OF 30 MODULES WITH INTEGRATED MICROINVERTER ( SPR-X21-335-BLK-D-AC SOLAR MODULES). SCOPE INCLUDES NEW LOAD CENTER (125A), SUNPOWER SOLAR MONITOR AND NEW DERATED SUBPANEL BREAKER. SYSTEM SIZE IS 10.05KWdc AND 9.6KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44976	16041-10000-09760	1118 S SAN JULIAN ST	90015	14	124-5A211 178	5145025001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.03532	-118.25342	T-24, CHANGE OF USE OF ONE TENANT SPACE FROM WHOLESALE PRODUCE TO SIT DOWN COFFEE SHOP. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES.(E) PANELS TOTAL SQ. FT. 2120.**4/27/16 (DM):Address confirmed by the contractor: 1118 San Julian St.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44977	17041-10000-27995	6109 S CRENSHAW BLVD	90043	8	105B185   629	4006004012	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			08/10/2017 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	33.98429	-118.33116	PC FOR POWER AND ENERGY FOR A NEW 75 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW 2000A 120/240V  3 PHASE 4 WIRE SERVICE, NEW PANELS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 20609 SQ. FT. B#17010-10000-01992	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44978	18041-10000-47138	1507 S HI POINT ST	90035	10	129B173   725	5068016007	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	05/09/2022 12:00:00 AM		Permit Finaled	08/30/2023 12:00:00 AM	ADDRESS	34.04987	-118.36938	POWER AND ENERGY PC FOR A NEW 5 STORY, 40 UNITS BUILDING OVER A 21,500 SF TYPE 1A SUBTERRANEAN GARAGE. SCOPE INCLUDES A NEW 1600A SERVICE, NEW PANELBOARDS, LIGHTING, AND RECEPTACLES. B#18010-10000-04481NOTE:FIRE ALARM VARIANCE HAS BEEN PAID.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44979	16041-10001-14840	14757 W ARMINTA ST	91402	6	189B149   482	2210021009	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.21385	-118.45492	CHANGES TO APPROVED SET OF PLANS. REDUCE SCOPE OF WORK. LEFT OUT RECEPTALCES IN WAREHOUSE AREAS. LEFT PANEL P1 EMPTY. MOST OTHER RECEPTACLES ARE EXISTING TO REMAIN. NEW SCOPE OF WORK IS TO UPGRADE SERVICE TO 600 AND RECONNECT EXISTING DISTRIBUTION TO NEW SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
44980	18041-10000-34607	1149 S BROADWAY	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.03859	-118.26015	Energy plan check for an office T.I located on the 7th floor of a high rise building. Scope includes new lighting and equipment with a total area of 3322-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44981	17041-10002-04673	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	33.94221	-118.40701	PLAN CHECK FOR CHANGES TO APPROVED SET OF TITLE 24 PLANS - PLANS INCLUDE ADDITION OF NEW LIGHTING WITH CONTROLS - CHANGES ARE REFLECTED UNDER DELTA 11T-24, PC FOR ENERGY ONLY. T.I. AT TERM-4. FIS ARRIVALS LEVEL 1 SCOPE INCLUDES NEW LIGHTS FOR KIOSKS, CONTROL ROOM. TOTAL AFFECTED AREA IS 17549 SQ. FT. B#16016-10000-30328	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44982	12041-20000-13124	3577 W BEVERLY GLEN TER	90077	4	159B149   192	2275024006	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2012 12:00:00 AM			Reviewed by Supervisor	07/17/2012 12:00:00 AM	PIN	34.13385033	-118.4533375	New roof mounted P.V. system (15.7KWdc)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44983	13041-10000-29795	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	Installation of new fire alarm system in Loyola Marymount University Life Science tenant improvement to meet proper coverage per NFPA 72.  1 new fire alarm control panel and 324 devices. (conduit only pulled for P1,2,3 on 10/24/2013)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44984	12041-10000-27283	3287 W WILSHIRE BLVD SUITE B	90010	10	135B197  1219	5502026021	C2-2, C4-2, R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	34.06197	-118.29379	CHANGE OF USE FROM EXISTING OFFICE TO COFFEE SHOP.   UNIT B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44985	15041-20000-14826	2029 S CENTURY PARK EAST Suite 500	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for title  24 only T.I. for for office CAA Crative Artist Agency.  Total area: 5,034 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44986	16041-20000-13560	22157 W ECCLES ST	91304	12	192B101   383	2010019005	RS-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.22279	-118.61024	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.88 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44987	18041-10000-22736	1851 S WOOSTER ST	90035	10	126B169   162	4303007028	R1R3-RG	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Issued	06/19/2018 12:00:00 AM	ADDRESS	34.04471	-118.3846	PLAN CHECK FOR ADDITION OF ENERGY STORAGE SYSTEM 14KWH(TESLA POWER WALL) TO EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44988	19041-20000-34925	12134 W VIEWCREST ROAD	91604	2	162B165   830	2369008017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Issued	09/04/2019 12:00:00 AM	ADDRESS	34.13883	-118.39714	Plan check for PV roof mounted system and energy battery back up system, PV system size: 9.135KW with 29 PV Modules and 1 inverter(7.6KW) and 2 battery 13.5KWh, 2 load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44989	16041-20000-44177	19724 W NORDHOFF PL	91311	12	195B117     3	2761001034	(T)P-1, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.23531	-118.56378	Plan check for energy only. New outdoor lighting installed under new entrance tower/canopy. 406sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44990	17041-20001-32165	23251 W CHASE ST	91304	12	192B093    64	2005014028	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.22364	-118.63404	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with AC coupled battery backup system.10.4kW ungrounded pv system [(1) 6.6kW + (1) 3.8kW].(34) 325W pv modules. (2) 5kW Tesla Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44991	14041-20000-26216	7740 N SALE AVE	91304	12	189B097  1012	2013017003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.21135	-118.6184	CENTRAL STRING INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44992	15041-20000-01180	6863 W CAMROSE DR	90068	4	151-5A185 328	5549025006	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2015 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.10908	-118.33928	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 18 MODULES IN TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
44993	15041-10000-38109	518 E COMMERCIAL ST guard bth	90012	14	130-5A215  71	5173002901	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.05288	-118.23427	One-story pre-fab Guard Booth	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44994	15041-20000-20524	15030 W VENTURA BLVD	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	07/02/2015 12:00:00 AM	ADDRESS	34.15272	-118.46063	Title 24 plan check only.  Total area = 1,050 sq. ft.  T.I. to existing commercial space.  New lighting and plug loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44995	14041-20002-17630	7341 W FOOTHILL BLVD	91042	7	202-5A199  94	2568010004	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	ADDRESS	34.25075	-118.29184	changes to an approved set of plans.  changes to reflect field conditions with lighting and energy calculations.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44996	18041-10001-12176	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM			PC Approved	02/25/2019 12:00:00 AM	ADDRESS	34.07417	-118.26931	CHANGES TO APPROVED PLAN BY REMOVING THE MAIN BREAKER FROM THE MAIN SECTION OF THE FIRE PUMP SERVICE. ALL CHANGES UNDER DELTA-3 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
44997	13041-10000-06732	19572 W VENTURA BLVD	91356	3	174B117   324	2164016027	C2-1VLD, P-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM			PC Approved	03/15/2013 12:00:00 AM	ADDRESS	34.17251	-118.55952	RENOVATION EXISTING RESTARANT SPACE FOR SMALL RESTARANT. OCCUPANT LOAD  < 100. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 814 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44998	17041-10001-41466	601 W 5TH ST 5th Floor	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	Supplemental PC for change in light fixture type on office TI and lighting layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
44999	18041-10000-04155	700 W 7TH ST 3RD FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM			PC Info Complete	02/14/2018 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR CORE SPACE FOR FUTURE TENANT ON THE 3RD FLOOR FOR TITLE 24 ENERGY ONLY. PREVIOUS WORK PARTIALLY DONE ON PERMIT 15041-10003-29087.ALL MARKED WORK ON THIS PLAN TO BE PERMITTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45000	18041-20000-43751	20841 W SPRUCE CIR #64	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.29535	-118.58831	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45001	17041-10000-43273	15553 W AQUA VERDE DR	90077	5	156B141    89	4378032009	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.12218	-118.4735	NEW ROOFTOP  SOLAR SYSTEM . CONSIST OF 25 MODULES ( SUNPOWER SPR-X21-345-D-AC AC MODULES) WITH MICRO-INVERTERS. SYSTEM SIZE  IS 8 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45002	19041-10000-44604	1999 S BUNDY DR 3RD FLR	90025	11	123B149   406	4259019007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.03406	-118.45593	T-24, ONLY. PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING SPACE. TOTAL AFFECTED AREA IS 7906 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45003	15041-10000-13246	2978 W WILSHIRE BLVD 1st flr	90010	10	133-5A201  49	5077013013	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.06166	-118.28637	pc for power and energy.  t.i. change of use from office to medical office. total area 3584 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45004	18041-10000-41558	10074 W SULLY DR	91352	2	189B181    75	2403019012	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM			Reviewed by Supervisor	11/08/2018 12:00:00 AM	ADDRESS	34.218	-118.34978	PC FOR ROOF MOUNTED PV ON SFD SCOPE INCLUDES NEW 43 MODULES WITH OPTIMIZERS AND 2 CENTRAL INVERTERS.SYSTEM SIZE 11.4 KWAC 12.69 KWDC(DC BATTERY UNDER   LGCHEM INSTALLED  AND IS UNDER SUPP)PARTIAL PERMIT PULLED ONLINE UNDER 18041-90000-38293	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45005	18041-10000-42014	6320 W HOLLYWOOD BLVD	90028	13	148-5A187 163	5546009005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Issued	11/02/2018 12:00:00 AM	ADDRESS	34.10145	-118.32737	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45006	12041-20000-19875	5450 S LINCOLN BLVD	90094	11	102B157   293	4211022004	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	33.97348	-118.43093	New methane detection system for Playa Vista Medical Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45007	15041-10000-16904	7000 W HOLLYWOOD BLVD 3RD FLR	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Expired	06/30/2017 12:00:00 AM	ADDRESS	34.10137	-118.34182	INTERIOR REWIRE TO UNITS NUMBERED 330, 332, 334, 335, 337, 338, 339 IN A HIGH RISE HOTEL. PLAN CHECK REQUESTED PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45008	18041-20000-18837	5901 W CENTURY BLVD Suite 1516	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	33.94572	-118.38685	Plan check for power and energy. Project site is a suite on the 15th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,751 sq. ft.Note: Building application has been generated under 18016-10000-00677	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45009	11041-20000-22810	3201 S LA CIENEGA BLVD Ste B	90016	10	123B173  1581	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM			PC Approved	10/25/2011 12:00:00 AM	ADDRESS	34.02965	-118.37211	T.I.  Remodel of light fixtures in an existing office space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45010	18041-10000-11096	11150 W SANTA MONICA BLVD ste 500	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	PC for power and energy. Installing new lights, receptacles and equipment. Total new load >400A. B#18016-10000-08283.Full floor tenant improvement at 5th floor to include non-load bearing partitions, millwork, finishes	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45011	16041-20001-06715	4151 W PROSPECT AVE STAGE 2	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	07-14-2016 Changes to an approved of plan. Changes include re-feed ATS from distribution(PA) to SUBSTATION-8. Changes has been clouded. {{{{{{Demolition of (E) distribution equipment.  New distribution equipment, ATS, and 150 kVA transformer.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45012	19041-10000-27492	1600 E 10TH ST	90021	14	123A213   348	5130005014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.02918	-118.24262	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45013	14041-20000-23868	5206 E MIRIAM ST	90042	1	153A225   116	5469003010	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.11476	-118.20367	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(12) SUNPOWER 327W MODULES(1) POWER ONE PVI-3.8-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45014	17041-10000-20925	501 E TERMINAL WAY	90731	15	018B205   127	7440027BRK	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	33.7422	-118.26534	Power plan check.  Installation of 5 new 125 kVA electric truck chargers fed from new 800 amp 480/277 volt switchgear.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45015	17041-20001-13158	420 E 20TH ST	90011	9	121-5A207  51	5127018011	[Q]CR-1VL-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			PC Approved	05/05/2017 12:00:00 AM	ADDRESS	34.02826	-118.2617	expeditepv2install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45016	18041-20000-36603	10345 W OLYMPIC BLVD 3RD FLOOR	90064	5	129B161   114	4319006052		Central	Hollywood, West Los Angeles	Hollywood Studio District, Westside		1909.02	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.05186	-118.41853	Plan check for Title 24 Energy only  in existing space office T.I. Total area: 6040 sq ft. B#18016-10000-30751	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45017	11041-10000-02740	8501 N LAUREL CANYON BLVD	91352	6	192B165   251	2633006017	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Approved	02/11/2011 12:00:00 AM	ADDRESS	34.22474	-118.39671	TI IN AN EXISTING RETAIL STORE. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45018	13041-10000-16366	5504 N FALLBROOK AVE	91367	3	174B097   797	2040019005	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	34.17026	-118.62308	PV1.  Install 12.25 kW DC roof-mounted solar array, interconnect with main service panel.  {2 transformerless inverters: Power-One PVI-5000} {50 modules: Trina Solar TSM-245}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45019	16041-10000-38415	777 S FIGUEROA ST #3050	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check Title 24 only in existing high-rise Building T.I. in office space 30th FL. Total area: 3,370 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45020	13041-10000-16534	155 N OCCIDENTAL BLVD	90026	13	138A203   347	5156018011	R3-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM			Corrections Issued	06/21/2013 12:00:00 AM	ADDRESS	34.0717	-118.27894	pc for power only. existing energy center building: REMOVE EMERGENCY (e) 115kw/144kva GENERATOR. affects emergency loads for buildings 92 and 55.building 92- ADD FIRE CONTROL CONNECTION AHEAD OF MAIN. 24kva inverter to handle existing emergency lighting.building 55-inverter 33kva to handle existing emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45021	16041-10003-20290	5822 S 3RD AVE	90043	8	108B189  1483	4005022006	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	33.98841	-118.32045	06/28/2016Changes to an approved set of plans note changes on delta 1. Changes include the relocation of pv equipment. (((PV1, rooftop solar instllation 2.5 kW AC system.   (10) SW275,   (10) M250 Enphase)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45022	18041-10000-27361	1510 S VERMONT AVE	90006	1	126B197   108	5056001028	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.04488	-118.29142	PC FOR ENERGY ONLY, CONVERSION OF EXISTING RETAIL,  SPACE TO ANIMAL CLINIC. SCOPE OF WORK INCLUDES NEW CIRCUITS AND LIGHTING. TOTAL SQ. FT. 1582.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45023	17041-20000-07052	2006 S PARNELL AVE	90025	5	129B157   548	4321006042	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	03/08/2023 12:00:00 AM	ADDRESS	34.05023	-118.42762	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 400A MSP.System size: 8.96kW ungrounded. (28) 360W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45024	11041-10001-27489	9615 N AQUEDUCT AVE	91343	12	201B141   410	2671008032	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.24497	-118.47406	Revision to approved plans to show existing service panel is 200A with existing 150A main breaker. Remove PV subpanel from installation. 14.1KW roof mounted Photovoltaic system single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45025	13041-20000-00201	21447 W MULHOLLAND DR	91364	3	165A105   175	2190002032	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.14574	-118.59946	New 5.39kw rooftop mounted PV system for an existing single family residence.  System is ungrounded/transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45026	17041-20001-15251	22121 W CLARENDON ST	91367	3	174B101   404	2169026110	CR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Apartment			01/11/2019 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.16978	-118.60882	"12-20-2018 Changes to an permitted set of plan, Changes include revised fire pump disconnect, feeder, and revised alumimum residential feeder schedule, remove occ sensor in all stair landing, add ""on/off"" pushbutton for all corridor, revised lighting fixture ""L3"" and ""L4"". All Changes has been clouded as delta 1 BLTN 3 and BLTN 4. Plan check only, permit covered under master application."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45027	13041-10000-25122	17205 S FIGUEROA ST	90248	15	066B201   278	6121001008	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	33.87463	-118.28247	TITLE 24 PLAN CHECK ONLY. 1 STORY. 14760 SQFT. WAREHOUSE. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45028	13041-10002-10268	700 WORLD WAY TERMINAL 7-TempPower	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	Plan check for power for motors only.  Load calc to be verified - MZsee Sasco's scope of work: 14041-10000-12456 (Temporary dist. panel T-DPC and 2 feeders)see Dynalectric's scope of work: 14041-10000-12462 (Dist panel PDP-A3 and PDP-B8 and MPC 101-104)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45029	13041-10000-13830	8201 W BEVERLY BLVD #402	90048	5	138B173   380	5514008046	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.07624	-118.36815	Plan check for power and energy. Medical office Suite #402. Existing building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45030	11041-10000-12908	3620 S VERMONT AVE !ST & 3RD-FL	90089	9	120B197   929	5039002030	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Approved	06/21/2011 12:00:00 AM	ADDRESS	34.02213	-118.29133	REMODELING OF OFFICES AND SUPPORT AREAS AT THE KAPRIELIAN HALLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45031	17041-20000-09876	12601 W PIERCE ST BLDG 4	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for installation of solar pv array, roof-mounted on apartment building (building 4).4kW ungrounded system. Central Inverter. (16) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45032	13041-10001-32393	2406 N PESQUERA DR	90049	11	141B133   363	4492020040	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.07884	-118.50823	Expedited RSES plan check per applicant request.(((PV1, Install 10.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 41 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45033	11041-20000-25244	13535 W VENTURA BLVD # D	91423	5	165B157   672	2360007038	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	ADDRESS	34.14768	-118.42818	NON-STRUCTURAL TENANT IMPROVEMENT TO (E) HEALTH CLUB: CREATE NON-BEARING WALL FOR RECEPTION AREA WITH NEW T-BAR CEILING PER P/BC 2008-040.   INSPECTOR FIELD VERIFY PERMIT VALUATION.ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45034	13041-10000-34004	3113 S 4TH AVE	90018	10	120B189   644	5052001037	C2-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.02597	-118.3214	PLAN CHECK FOR POWER AND ENERGY PER APPLICANTS REQUEST. CHANGE OF USE FROM (E) RETAIL STORE ON GROUND FLOOR TO (N) RESTAURANT. 1353 SQFT. SUBWAY RESTAURANT.building pc # 13016-20000-24593	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45035	15041-10000-24957	1145 W 6TH ST	90017	1	132A207   254	5152001002	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.05474	-118.2633	Change of use of the first floor of an existing two story, type VB, office building to out- patient clinic; Tenant improvement; site improvement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45036	13041-20000-00186	10044 N BURNET AVE	91345	7	204B145   849	2660022021	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.25308	-118.46291	New 5.52KW rooftop mounted PV system for an existing single family residence.   System is ungrounded/transformerless and uses SolarEdge Optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45037	10041-10000-15582	612 S FLOWER ST 1st Floor	90017	14	129A209   264	5144005124	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			08/10/2010 12:00:00 AM			PC Approved	09/07/2010 12:00:00 AM	ADDRESS	34.0497	-118.25759	Title 24 and emergency lighting for high rise appartment  bldg.  (On the 1st floor)  Plan Check ONLY.    <<<<<<<<<PERMIT WAS ISSUED AND FINALED UNDER 10041-10000-17810>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45038	17041-10000-18975	2290 N PANORAMA TER	90039	4	148-5A205 242	5432029005	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	Yes	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.10102	-118.27062	PC FOR BATTERY STORAGE UNIT. USING TESLA POWERWALL 2.0. SYSTEM IS 5.8KW WITH STORAGE UP TO 13KWH.Note. The service has a backfeed solar system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45039	17041-10001-45005	927-931 N SYCAMORE AVE	90038	4	144B181   718	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.08796	-118.34291	"DELTA ""1"" CHANGES TO APPROVED PLANS FOR CHANGES TO 11,211 SQR FT OF LIGHTING AND NEW PANELS & CIRCUITS PER INSPECTOR'S REQUEST. <<<PC FOR WAREHOUSE TI FOR POWER AND ENERGY. SPLITING EXISTING SPACE INTO TWO SPACES FOR FUTURE TENANTS. INSTALLING MINIMUM LIGHTING AND EXIT SIGNS REQUIRED PER BUILDING CODE.SCOPE INCLUDES NEW 300KVA TRANSFORMER AND 2 NEW ( ONE OF THE PANEL RATED AT 600A) CIRCUITS AND LIGHTS TOTAL AFFECTED AREA 10078 SQ.FT. B# 17016-10000-33238>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45040	15041-10000-23578	3311 W SAN FERNANDO ROAD	90065	13	153B209   120	5458007012	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.11792	-118.24864	T24 ONLY. REMOVE HID LIGHT FIXTURESAND REPLACE WITH NEW LE FIXTURES. TOTAL AREA 3750 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45041	15041-20000-40810	521 N CURSON AVE	90036	5	141B177  1044	5526028008	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.08091	-118.35542	PV1, rooftop mounted solar system 3kW AC. interconnected to (upgraded) 200A Service.(12) SW275 Mono Black(1) SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45042	19041-20000-18540	1407 N MCCOLLUM ST	90026	13	142-5A205 445	5424016027	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.08332	-118.26767	PLAN CHECK FOR NEW PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 12.395KW DC/10.5KW AC CEC/8.88KW AC. SCOPE OF WORK INCLUDES (37) LG SOLAR PV MODULES WITH ENPHASE IQ7 MICROINVERTERS AND A ENPHASE AC COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45043	13041-10000-30126	4908 N RUPERT AVE	91316	5	168B129   274	2182005033	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.15875	-118.52165	PV1, Install 8.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Fronius IG Plus V 7.5. 33 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45044	17041-20002-18658	8532 N HASKELL AVE	91343	12	192B141   155	2673011057	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.22566	-118.47624	9.13.2017 - Plan check for changes to approved set. Adding one Tesla Powerwall 2. Reorganize distribution - add subpanel for PV and Tesla powerwalls which backfeeds/interconnects into subpanel with relocated house loads. Main panel is shown as having no other loads. Changes clouded.======pv1install roof mounted pv system sized 5.2kw interconnected with msp with battery back up.AC coupled system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45045	17041-20000-12397	22201 W LEADWELL ST	91303	3	186B101   737	2023025028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.20389	-118.6106	pv1install roof mounted pv system sized 9.1kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45046	13041-20000-12676	1645 N BEVERLY DR	90210	5	147B161   123	4355014030	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01, 2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.10059	-118.4158	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.90KW. [SOLAR MODULE: CANADIAN SOLAR CS6X-300P] [INVERTER: AURORA MICROINVERTER MICRO-0.3-I-OUTD-US-240]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45047	17041-10002-21813	20133 W SATICOY ST	91306	3	186B113   120	2114004045	(Q)C1.5-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.20848	-118.57211	POWER PLAN CHECK FOR A NEW PANEL AND CIRCUITS IN AN EXISTING RESTAURANT. T-24 ENERGY WAS CHECKED UNDER 17041-10000-21813	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45048	16041-10000-45781	380 WORLD WAY FAR-EAST	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	"Full Plan check. Addition to (E) Bradley West Terminal. Install new lighitng, power, and emergency power to LAX MSC TUNNEL-EAST building. Total area: 37000 sq. ft.  *Scope and plan check is noted ""UNDER TUNNEL EAST PROJECT"" B#16014-10000-02498"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45049	09041-20001-10547	100 S THE GROVE DR	90036	4	138B177   451	5512004908	OS-1XL-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM	08/10/2010 12:00:00 AM		Permit Finaled	02/03/2011 12:00:00 AM	ADDRESS	34.0746	-118.35615	revision delta 15 to approved plans permit # 09041-20000-10547	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45050	18041-10002-08362	10314 N WOODWARD AVE	91040	7	204B193   603	2559008020	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM			PC Approved	05/10/2018 12:00:00 AM	ADDRESS	34.25645	-118.30689	Fees for expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45051	18041-10001-17074	816 N GLENMERE WAY	90049	11	138B137   457	4426028017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.07243	-118.4922	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9 KW + ENERGY STORAGE 26KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45052	15041-10000-08987	380 W WORLD WAY Terminal 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	PIN	33.94094587	-118.40577128	New fire alarm system (full evacuation) for Terminal 4 connector on levels 1-4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45053	16041-30000-39958	1620 E 108TH ST	90059	15	088-5A213  94	6069001019	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	33.93773	-118.2454	Plan check for PV roof mounted system SFD. System size: 3.8kW with 14 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45054	13041-10000-01588	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	DODGERS STADIUM-RETAIL/CONCESSION IMPROV LVL7. 600A swbd. pc for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45055	18041-10001-04508	563 N HOOVER ST	90004	13	141A201   145	5539028004	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Apartment			05/24/2019 12:00:00 AM			PC Approved	05/24/2019 12:00:00 AM	ADDRESS	34.08125	-118.28469	Change to approved set by updating the floor plan with more detail on fire alarm devices.(((PC FOR NEW FA  IN APARTMENT BUILDING. SCOPE INCLUDES 2 PANELS  AND 46 DEVICES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45056	14041-20000-26767	23339 W KESWICK ST	91304	12	186B093    40	2027001014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.20966	-118.63712	FEE PERMIT IS $0.00 BY STATE SENATE BILL NO.1222PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECTED MSP.(52) KYOCERA KD255 MODULES(52) POWER OPTIMIZERS(2) SOLAR EDGE INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45057	18041-20000-28715	23416 W COMMUNITY ST	91304	12	192B093   295	2005016022	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.22103	-118.63681	Plan check for a PV1 roof-mounted PV system. System size is 10.56 kWdc/9.71 kWac-CEC and consists of (2) inverters, (33) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45058	14041-10001-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			11/16/2016 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	33.95637	-118.3838	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGING COPPER TO ALUMINUM. RECHECKING FEEDER SIZES AND AIC RATINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45059	18041-20000-35795	1801 S CENTURY PARK EAST ste 840	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM			PC Approved	09/19/2018 12:00:00 AM	ADDRESS	34.06201	-118.41537	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45060	15041-10002-27587	22524 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.8214	-118.30137	CHANGES TO APPROVED SET OF PLANS. ADD PERFORMANCE METER AND FUSED DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45061	12041-10000-03798	20946 W DEVONSHIRE ST	91311	12	204B109   173	2747001091	C2-1, CR-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM			PC Approved	03/01/2012 12:00:00 AM	ADDRESS	34.25708	-118.59006	TI in an existing office building. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45062	14041-10000-12882	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.0484	-118.26248	NEW FA FOR parking structure. not a highrise per building application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45063	11041-10000-22159	550 S FLOWER ST	90071	14	130-5A209 186	5151024004	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM			PC Approved	10/17/2011 12:00:00 AM	ADDRESS	34.05028	-118.25708	T.I. to an existing Gift Shop.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45064	19041-10000-24569	425 S PACIFIC AVE	90731	15	015B197    95	7451027021	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	33.74001	-118.28807	PC (FA SYSTEM) FOR A CLINIC. 1 FACP and 81 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45065	10041-10000-04643	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	New fire alarm for hotel Bel Air building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45066	19041-20000-34011	10925 W BLUFFSIDE DR	91604	2	162B173   304	2366021008	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	04/07/2021 12:00:00 AM	ADDRESS	34.14115	-118.36774	Plan check for PV roof mounted PV system, PV system size: 69.12KW DC, 62.7KW AC with 192 PV Modules and 7 inverters(9) connected to 1200A 120/208 Volts 3 phaseFees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45067	13041-10000-23149	19230 W KNAPP ST	91324	12	198B121   590	2762036012	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.23801	-118.55138	PV1 8.82KWdc 240V XFMR(-)INV. 1STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V10][( 36) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45068	14041-20000-16729	14754 W SATICOY ST	91405	6	186B149   205	2218002002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Expired	08/01/2016 12:00:00 AM	ADDRESS	34.20832	-118.45499	PV1.  Install 5.25 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45069	16041-10001-37879	14235 W VENTURA BLVD	91423	4	165B153   335	2265019007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			PC Approved	10/31/2016 12:00:00 AM	ADDRESS	34.15022	-118.44335	PC FOR ADDITIONAL LIGHTING. ADDED MORE DOWNLIGHTS IN DINING AREA. PC FOR DELTA 1 CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45070	18041-20000-35671	1721 S GRANVILLE AVE	90025	11	126B149   923	4262015009	RD1.5-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Apartment			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.03957	-118.45563	Plan check for Title 24 only. Project site is a 4-unit, 3-story apartment building. Project scope is common area and outdoor lighting. Total lighting area = 6,946 sq. ft.Note: Building permit has been issued under 17010-10000-0297	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45071	18041-20000-05110	2720 S GREENFIELD AVE	90064	5	123B157   742	4256020043	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.0328	-118.42734	addition of (1) tesla powerwall to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45072	10041-20000-09630	1950 S SAWTELLE BLVD s.320	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	05/21/2010 12:00:00 AM		Permit Finaled	06/23/2010 12:00:00 AM	ADDRESS	34.04129	-118.44377	s.320 office t.i.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45073	13041-10002-14444	6901 N TUJUNGA AVE	91605	2	183B173   184	2320002013	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.19626	-118.37921	CHANGES TO APPROVED SET: ADDING 21.6KVA PDU TO BE SUPPLIED FROM PANEL LE1; ADDING NEW CIRCUITS TO PANELS 2LA;2LB;2LC;2LD;2HA;LE2 AND LE3 FOR OWER AND LIGHTINGMain App Description:    NEW BUILDING WITH NEW 277/480 VOLT 3-PHASE 4-WIRE, 3000 AMP SERVICE. 66,469 SQUARE FEET OF INDOOR LIGHTING AND 3,036 SQ FT OF OUTDOOR LIGHTING. OFFICE, INDUSTRIAL, AND STORAGE USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45074	10041-10000-21080	1813 N CAHUENGA BLVD	90028	13	150A187   283	5546001400	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM			PC Approved	10/22/2010 12:00:00 AM	ADDRESS	34.10443	-118.33025	CHANGE OF USE TO A SUBWAY SANDWICH SHOP.   PLAN CHK IS FOR TITLE 24.  PERMIT WAS ISSUED 10041-90000-22007	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45075	17041-10000-36408	1560 W CERRO GORDO ST	90026	13	145-5AZ11-308	5443018019	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.09216	-118.24774	Install new rooftop solar on a SFD, 5.51 kW DC, (19) microinverters  with (19) modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45076	16041-20000-08942	11139 W SHELDON ST	91352	7	204B173   222	2528017035	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.25375	-118.37416	Plan check for a PV1 ground-mounted PV system. System size is 5 kWac and consists of (1) inverter and (15) modules. PV system is interconnecting with a 225-amp, top-fed MSP with a new 200-amp MCB.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45077	19041-10001-37797	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK ONLY, FOR CHANGES TO APPROVE SET, CHANGES INCLUDE REVISIONS, TO LIGHTING LAYOUT, T24 HAS BEEN UPDATED ACCORDINGLY. ALL CHANGES ARE CLOUDED UNDER DELTA 1ORIGINAL SCOPE--------------------------------------------------------------------------------------ENERGY PC ONLY FOR TWO NEW RESTROOMS IN COMMON AREA OF GROUND FLOOR PARKING GARAGE. AREA OF SCOPE 317SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45078	16041-20002-00525	127 S SAN VICENTE BLVD Street-level	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM			PC Approved	03/07/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	Revisions to approved set of plans.  Changes to distribution connection points of panel B1LB and addition of repaired feeder into scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45079	17041-10000-16848	127 S SAN VICENTE BLVD 6TH FLOOR	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			PC Info Complete	05/19/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	Title 24 plan check.  T.I. to existing office area on 6th floor of highrise building.  Convert open office to private office and convert copy room to work room.  New lighting and receptacles.  Total area = 1,048 sq. ft.       Building permit #17016-10000-12443	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45080	15041-20000-34154	14559 W HESBY ST	91403	4	171A151   152	2263033012	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Closed	05/25/2017 12:00:00 AM	ADDRESS	34.16226	-118.45078	PV1 SFD TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM USING TOTAL OF 34 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45081	14041-10000-02356	14006 W RIVERSIDE DR #247	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO BRIGHTON STORE IN FASHION SQUARE MALL. SUITE #247.      956 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45082	16041-20000-41582	261 S FIGUEROA ST	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.05546	-118.25446	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45083	11041-10000-24606	1500 S OLIVE ST	90015	9	124-5A207 184	5134023009	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.03567	-118.26482	PLAN CHECK POWER AND ENERGY  FOR NEW MEDICAL OFFICE IN AN EXISTING 6 STORY HIGH RISE BUILDING. SCOPE OF WORK ON 1ST, 2ND, AND 4TH FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45084	10041-10000-07009	777 E 10TH ST # 104	90021	9	124-5A211 244	5132002028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	04/23/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.03437	-118.24974	FIRST TENANT IN RETAIL SPACE- ADDING TRACK LIGHTING CKT AS POWER/LIGHTING SYSTEM WERE APPROVED ON SHELL PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45085	18041-10000-18986	5523 S BANDERA ST	90058	9	108B213   348	5105011030	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	33.99221	-118.24018	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED LIGHTS FOR INDOOR USE. TOTAL AFFECTED AREA IS 4025 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45086	14041-20000-07069	7257 W SUNSET BLVD	90046	4	147B181   607	5548010022	C4-1D	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.09816	-118.3483	Install general lighting in starbucks area inside Ralphs supermarket.  Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45087	10041-10000-14713	1440 S BUTLER AVE Bldg 9	90025	11	129B149   200	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.04759	-118.45301	NEW SERVICE , PANELBOARDS AND CIRCUITS FOR 21 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45088	14041-20000-34444	4537 N GABLE DR	91316	5	168B125   574	2184017010	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.15336	-118.52774	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45089	15041-20000-14262	15500 W MORRISON ST	91403	5	168B141   117	2261034028	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	34.16013	-118.47222	Plan check for PV roof mounted 6.0kWac system with 25 modules(kyocera KU2606XPA) and 1 inverter(6.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45090	12041-10000-10499	1502 E OPP ST	90744	15	033B213   666	7425040009	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	33.78372	-118.24473	creating 5 new offices on the 1st floor and 1 office on the second floor.Plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45091	13041-10000-25634	453 S SPRING ST	90013	14	129A211    87	5149024001	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Expired	11/17/2015 12:00:00 AM	ADDRESS	34.04778	-118.24948	PV2.  Roof-mount commercial high-rise, 65.8 kW DC.  1 central inverter: Fronius CL 55.5 Delta.  280 panels: TaleSun TP660PNOTE TO CASHIER:ROOF-TOP MOUNTED SYSTEM MAXIMUM FEE HAS BEEN REACHED PER SENATE BILL122 ; PERMIT FEE IS O	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45092	14041-20000-07530	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	33.97749	-118.41246	LARGE TI FOR EXISTING OFFICE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45093	13041-10000-29533	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	"Plan check for temporary installation for switchboard ""PA"" to be connected to ""NPG"" while 1HPB under construction. See plan check for #12041-10002-07640 for approved final installation."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45094	12041-10000-04445	404 S FIGUEROA ST #104	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM			PC Approved	03/19/2012 12:00:00 AM	ADDRESS	34.05326	-118.25596	T.I. to an existing gift shop at the Bonaventure hotle ste 104.  New recetptacles and lighting, PLAN CHECK ONLY, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45095	16041-10000-09839	1116 S ABBOT KINNEY BLVD	90291	11	108B145  1143	4238003003	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	33.99154	-118.47003	T-24, TI TO AN (E) RETAIL STORE, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 933.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45096	19041-10000-08120	406 W AVENUE 42	90065	1	147A223   152	5465020006	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.0974	-118.21357	New Installation of [1] LG chem battery 9.8kwh 400V,  and [1] 125A critical load center to connect to 7.6 kW AC rooftop PV system already permitted under permit# 18041-90000-25507	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45097	19041-10000-50975	2400 N HYPERION AVE	90027	4	148-5A205  83	5432003008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	02/02/2021 12:00:00 AM		Permit Finaled	09/27/2021 12:00:00 AM	ADDRESS	34.10277	-118.27288	Energy plan check only, Area of scope (2,362)sf.INTERIOR AND EXTERIOR ALTERATION OF (E) OFFICE SPACE. NEW ACCESSIBLE RESTROOMS AND  NEW WINDOWS. UNDERPINNING (E) FOUNDATION AND NEW PAD FOOTINGS PER ENGINEER OF RECORD. (NO CHANGE OF USE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45098	16041-10001-33811	2710 E 5TH ST	90033	14	124-5A223  17	5185010008	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.03718	-118.20853	Changes to the approved set of plan. Changes include the location of main switchgear(3/1/2017). The main service was upgraded to 200 A and panelboard is 225A. Changes has been clouded as delta 1<<<PV , INSTALL NEW 3.27 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(10)MODULES AND AC INVERTERS :SPR-E20-327-C-AC>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45099	16041-20000-44611	12484 N GLADSTONE AVE	91342	7	219B161   168	2525019062	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29696	-118.41287	Plan check for power only. New 1200A service (replacing 1600A service of same voltage class and phase). Reconnect existing feeders and equipment to new distribution board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45100	16041-30000-17651	175 W 42ND ST	90037	9	114A203    99	5111019022	RD2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			Reviewed by Supervisor	05/31/2016 12:00:00 AM	ADDRESS	34.00745	-118.27574	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (15) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45101	18041-20000-23664	5645 N CLEON AVE	91601	2	174B173   744	2415006023	R2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.17345	-118.36822	Plan check for a PV1 roof-mounted PV system. System size is 10.89 kWdc/10.16 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (33) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45102	15041-20000-10418	15503 W VENTURA BLVD Suite 300	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.15504	-118.4723	Title 24 plan check only.  Total area = 4,519 sq. ft.T.I. to existing low rise office space.  Work includes lighting, recepticles, and mechanical equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45103	19041-10000-09762	800 W 6TH ST 10TH FLOOR	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	PLAN CHECK FOR TITLE 24 ONLY  DISABLED ACCESS RESTROOM UPGRADES TO EXISTING RESTROOM FACILITIES ON THE 10TH FLOOR. TOTAL EFFECTED AREA 965 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45104	11041-10000-13731	1545 W WILSHIRE BLVD bsmnt	90017	1	132A205   208	5142027025	CW	Central	Westlake			2091.02	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.05543	-118.26977	new panelboard and circuits in renovating offices on the bsmnt flplan check is for title24 and 1 ea emergency ckt ; permit fee is in Inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45105	11041-10000-25234	4005 N VERDUGO ROAD	90065	14	156A217    77	5459015013	[Q]C1.5-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM			PC Info Complete	02/22/2012 12:00:00 AM	ADDRESS	34.12323	-118.23153	"New 600A service for a medical offices and T.I.  for both stories of a stand alone building.  Full plan check.  ((((Building permit says ""Medical Office"", but plan shows installation of medical equipment.)))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45106	19041-10000-01874	933 S VERMONT AVE	90006	10	132B197  1017	5094026021	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.05473	-118.29182	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45107	17041-20000-00110	10649 W JIMENEZ ST	91342	7	210B177    27	2529011021	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.27595	-118.36294	Plan check for installation of solar pv system, roof-mounted on SFD and detached garage. Interconnect with a 200A MSP.7.6kW ungrounded system. (34) 255W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45108	11041-10000-16781	14812 W OXNARD ST	91411	4	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Info Complete	08/17/2011 12:00:00 AM	ADDRESS	34.17923	-118.45564	NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45109	15041-10002-09206	432 S SAN VICENTE BLVD	90048	5	138B173  1162	5511044013	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.07067	-118.37575	CHANGES TO AN APPROVED SET. SCOPE OF WORK INCLUDES THE ADDITION OF NEW FIXTURES AND RECEPTACLES. (((TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1684.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45110	11041-20001-01325	5525 N KLUMP AVE	91601	2	174B173  1181	2350006026	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			05/06/2011 12:00:00 AM			PC Approved	05/26/2011 12:00:00 AM	ADDRESS	34.17064	-118.37542	Supplemental application for review incomplete plans submitted previously and to include T24 Energy.  New 5-story building with 51 units.  New electrical service, panels, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45111	11041-20000-11919	11212 W VANOWEN ST	91606	2	180B173    39	2319011014	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	PIN	34.1933171	-118.37532417	Install outdoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45112	15041-10000-30062	9830 W BEESON DR	90210	5	150B157    21	4384026007	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.11111	-118.42517	PV1. Installment of a roof mounted solar system for a residential site. Scope: (30) microinverters rated at 250w, Total rate = 7.5Kw(30) moduules LG 300 N1C(30) Enphase Energy M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45113	19041-20000-11691	554 N GOWER ST	90004	4	141B189   857	5523027039	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.08052	-118.32257	INSTALLATION OF NEW 7.56KW DC/6.615KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (21) SUNPOWER 360WPV MODULES WITH INTEGRATED 315W MICRO INVERTERS, AND A 100A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45114	18041-10000-11078	12800 W WENTWORTH ST	91331	6	198B161   395	2629027***	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	ADDRESS	34.23659	-118.41161	NEW LIGHTING SYSTEM IN A COMMERCIAL SPACE USED FOR HYDROPONIC AGRCUTURAL ENTERPRISE; PERMIT FOR POWER 17041-20000-39520 HAS BEEN FINALISED.PLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45115	13041-20001-34546	5152 N TOPANGA CANYON BLVD #A	91364	3	171B101   861	2169005014	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	34.16331	-118.6056	EXPEDITE FEES ONLY            <<<New rooftop PV system using DC-DC converters.  System is UNGROUNDED.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45116	19041-10000-29544	8511 N FAUST AVE	91304	12	192B097    85	2004013009	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.22475	-118.62051	(ePlan) PLAN CHECK FOR A NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 10.56KWdc / 9.71KWac.  SYSTEM CONSISTING OF 32 MODULES(Panasonic Group SANYO Electric VBHN330SA17) WITH MICROINVERTER(IQ7X-96-2-US)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45117	11041-10000-12780	600 W WORLD WAY WEST TERMINAL-# 6	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/11/2011 12:00:00 AM	PIN	33.94386803	-118.39979044	REPLACEMENT OF 3 ELEVATORS IN TERMINAL 6 AT LAXPLAN CHK IS REQUESTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45118	14041-10000-12853	3351 S GAFFEY ST	90731	15	006B197     4	7469018904	OS-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	33.71374	-118.29306	Plan check for power and energy. Pool with high voltage service and open delta. Fire alarm variance to be deferred.  BLDG#14016-10-06857: RESTORATION OF POOL EQUIPMENT ROOM AND ADD.  STORAGE ROOM TO (E)  POOL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45119	15041-20000-07673	2130 N TRENTLY LANE	90210	4	150B165    26	4388009025	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2015 12:00:00 AM			Verifications in Progress	05/05/2015 12:00:00 AM	ADDRESS	34.11116	-118.40265	Plan check for power only.  Service upgrade for existing signle family dwelling to 600 A.  All new electrical equipment except the standby generator. this is plan check only. permit already issued from building application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45120	14041-20000-33192	5619 N FAUST AVE	91367	3	174B097   513	2040008027	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.17248	-118.61999	PV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING SINGLE INVERTER W/ ISOLATION TRANSFORMER. SYSTEM USES 3 STRINGS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45121	18041-10000-39970	9409 N OWENSMOUTH AVE	91311	12	198B105    65	2746014004	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.24126	-118.60205	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY. Total Sq. ft. 88,100.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45122	13041-20000-23262	2251 N LINDA FLORA DR	90077	5	153B145   127	4377010004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.11425	-118.4647	single dewlling. pc for electrical system. per inspector request, pc for single line diagram. supervisor okay for single line only. permit already issued. building 95% complete. pc only for single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45123	15041-10002-27802	8480 W 3RD ST	90048	5	138B173   779	5511032029	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM			PC Approved	01/12/2016 12:00:00 AM	ADDRESS	34.07317	-118.37579	1/12/16changes to an approved set of plans. Note changes on delta 2, changes include the reduction of fixtures and t-24 recalculations. (((PC FOR CHANGES NOTED DELTA 1 REVISION. PC FOR CHANGE IN DAYLIGHT ZONES ON FLOOR PLANS. INSTALLATION OF PHOTOCELL FOR DAYLIGHT HARVESTING.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45124	13041-10000-13477	300 E 9TH ST	90015	14	126A211   210	5145016022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.03985	-118.2534	PC FOR ENERGY ONLY. TI TO (E) STARBUCKS COFFEE SHOP. less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45125	10041-10000-21312	426 S SAN PEDRO ST 1st fl	90013	9	127-5A213 633	5147005***	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM	11/05/2010 12:00:00 AM		Permit Finaled	04/14/2011 12:00:00 AM	ADDRESS	34.04486	-118.24331	CHANGE OF USE FROM RETAIL TO OFFICE. AND T.I. FOR AN OFFICE FOR THE L.A. COUNTY DEPT. OF MENTAL HEALTH; NEW PARTITION WALLS & FURNITURE LAYOUTplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45126	18041-20000-10427	617 N DILLON ST	90026	13	141A203   375	5401014025	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Issued	03/22/2018 12:00:00 AM	ADDRESS	34.07899	-118.27903	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP, 4 RPS AND 227 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45127	13041-10000-11982	23240 W SCHOENBORN ST	91304	12	192B093   349	2005010016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.22053	-118.63382	PV1 transformerless ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE FAMILY DWELLING. SYSTEM SIZE IS 11.75KW USING 47 MODULES IN 5 STRINGS AND TWO INVERTERS. [MODULES: TRINA SOLAR # TSM-250PA05.08 |||| INVERTER: POWER-ONE # POWER-ONE-PVI-60000-OUTD-US AND POWER-ONE # POWER-ONE-PVI-3.6-OUTD-S-UD]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45128	14041-10000-03958	3620 S VERMONT AVE	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.02213	-118.29133	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45129	17041-20001-07882	17031 W GUNTHER ST	91344	12	213B133   130	2607002033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			PC Approved	04/14/2017 12:00:00 AM	ADDRESS	34.28343	-118.50347	expedite.pv1install roof mounted pv system with battery backup connect to msp.This system is an addition to an exisitng system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45130	14041-20000-22944	8905 N MEGAN AVE	91304	12	195B101   104	2010021044	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.23206	-118.60652	PV1.  Install 9.18 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45131	18041-20000-30791	3445 W DESCANSO DR	90026	13	142-5A203 521	5427028019	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.08664	-118.27771	PV1.  Install 5.9 kW roof mounted grid tied PV system.  (20) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45132	11041-10000-27300	200 E WORLD WAY Terminal-#2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Closed	06/28/2013 12:00:00 AM	PIN	33.94678571	-118.40391619	INSTALL A NEW FIRE ALARM SYSTEM IN TERMINAL #2 OF LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45133	12041-20000-28568	12925 W MAGNOLIA BLVD	91423	4	171B161   450	2345017031	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			11/28/2012 12:00:00 AM			PC Approved	11/28/2012 12:00:00 AM	ADDRESS	34.16502	-118.41473	Existing permit 12041-20000-17897, plan check for lighting systems only.  Inspector please verify that the inline circuit breakers are integral to the lighting track.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45134	19041-10000-52840	10900 S VERMONT AVE	90044	8	088-5A199 126	6075001017	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	33.9371	-118.29135	Design build. Energy plan check for a commercial building T.I. Scope includes new lighting and equipment with a total lighting area of 5,368-SQ FT.Note. portion of permit fee is paid under 19041-30000-27596.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45135	14041-20000-28146	16501 W VENTURA BLVD Ste 615	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.1578	-118.49275	TI to (E)  commercial office space in existing commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45136	13041-20001-01562	801 E 7TH ST	90021	14	126A213   287	5147028039	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.03955	-118.24481	"new 600a panelboard(((supplemental to approved set of plans. changes to approved set. service is existing. changes only to AIC rating. ))))T.I. RETAIL AT FIRST FLOOR ENTIRE FLOOR;  CREATE 17 RETAIL TENANTS. (PC TO VERIFY OCCUPANT LOAD). ""COMPLY WITH DEPARTMENT ORDER effective date 02/14/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45137	13041-10001-32947	17819 W SIDWELL ST	91344	12	219B129   652	2601071004	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	34.3004	-118.52266	Expedited RSES plan check per applicant request.[][]PV1, Install  9.75 kw DC roof-mounted solar array for a 2 story house, interconnect with main service panel.Transformered inverter: Sunny Boy SB8000US-12. 39 modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45138	18041-20000-33215	8411 N FALLBROOK AVE 3rd flr-ste 300	91304	12	192B097   579	2005002014	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.2236	-118.62596	ti to an existing commercial building.  adding new lighting new controls to existing panels for (2) restrooms and (1) elevator lobby in the third floor only.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45139	12041-10000-30209	13833 W VENTURA BLVD	91423	5	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Closed	12/20/2012 12:00:00 AM	ADDRESS	34.1487	-118.43426	(#103)  CHANGE OF USE FROM RETAIL/OFFICE TO MEDICAL OFFICE; EPC IS FOR POWER & ENERGY.	N	N	Express Permit	06/10/2024 12:00:00 AM
45140	15041-20000-20549	14720 W RINALDI ST	91340	7	213B149   249	2613017005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Expired	07/26/2017 12:00:00 AM	ADDRESS	34.28028	-118.45373	Plan check for PV roof mounted system. System size: 6.0kW with 1 inveter(6.0kW) and 29 modules. Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45141	17041-20000-27769	16238 W RAYMER ST	91406	6	189B137    19	2205029037	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Issued	08/16/2017 12:00:00 AM	ADDRESS	34.21771	-118.48681	permit fee zero state senate bill no.1222Plan check for a PV2 roof-mounted PV system. System size is 86.6 kWac and consists of (3) inverters, (310) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45142	17041-20001-22700	11454 N DORAL AVE	91326	12	213B121   457	2822031026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	34.27976	-118.54874	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45143	14041-20000-27880	920 W BLOOM WALK 4th floor-rm 414,416	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.01996	-118.28938	Plan check for energy only. Change 4th floor lab to office. TI, including new receptacles and lighting (incl. emergency). 1,391sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45144	12041-10000-22907	1024 N SEPULVEDA BLVD	90049	5	141B141   142	4368010024	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Public Safety Only			09/26/2012 12:00:00 AM	09/26/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.08205	-118.4732	New fire alarm for a Nursing Care.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45145	18041-10000-39642	11001 S AVIATION BLVD	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93547	-118.37957	REMOVE INDOOR & OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45146	13041-20000-10970	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.14441	-118.39252	"New roof mount photovoltaic systems at CBS Studios on buildings 3, ""Scoring"", 4&5, Carport, 15&Grip, 18, 19, 20.   416kw DC system.  (Variance has been approved for alternate bus calculation)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45147	15041-10000-28609	8075 W 3RD ST	90048	5	138B177   725	5511022032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM			PC Approved	08/31/2015 12:00:00 AM	ADDRESS	34.07225	-118.36564	IN EXISTING EMPTY TENANT SPACES, ALTERATIONS MADE TO PREPARE FOR RENTING SPACESPLAN CHK IS FOR TITLE 24; PROPOSED NEW LOAD IS LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45148	18041-10000-23985	707 W WILSHIRE BLVD 30TH FLR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM			PC Approved	06/27/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER EXPRESS 18041-90000-22070PC FOR INTERIOR RESTROOM REMODEL TO (E) OFFICE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTSTOTAL 555 SQ.FTB#18016-10000-16288	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45149	11041-20000-20691	8378 W MELROSE AVE penthouse	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM			PC Approved	09/28/2011 12:00:00 AM	ADDRESS	34.08341	-118.37285	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45150	15041-20000-34162	11135 W BURBANK BLVD 1-70	91601	2	174B173   874	2337031007	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.17237	-118.37358	Plan check for power and energy. Project site is a new 4-story, 70-room hotel. Building is (1) level of above-ground parking and (3) levels of hotel rooms. Service size is 1600 Amps.Note: Building application has been filed under 15010-20000-03681	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45151	15041-10000-09821	6801 W HOLLYWOOD BLVD T3-315	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR COURTYARD RESTURANT. TOTAL AREA 636 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45152	16041-10000-07701	1875 CENTURY PARK EAST 1200	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM			PC Info Complete	03/04/2016 12:00:00 AM	PIN	34.06084104	-118.41471001	Tenant improvment, install new light fixtures and controlled receptacles in Ste. 1200. Total area 10,056 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45153	14041-10001-07234	12015 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	33.98173	-118.4029	CHANGES TO PERMITTED SET OF PLANS- ADDITION OF 2 METHANE SENSORS  AS USE OF BUILDIN 1 CHANGED ((((((((((METHANE MITIGATION PLANS. BUILDING 2 OF 2. ELECTRICAL PLANCHECK  APPLICATION # 13041-10000-35618	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45154	15041-10000-13941	600 WORLD WAY Term 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	first tenant in commercial spacefull plan chk	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45155	14041-10000-11400	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.09786	-118.29745	plan check for energy only. Replacement of existing 250 kW emergency generator in a medical office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45156	17041-10001-42231	6703 W MELROSE AVE	90038	5	141B181   558	5524013031	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.08359	-118.33985	PLANCHECK ONLY FOR DELTA 2 CHANGES. CHANGES TO LOADS, SINGLE LINE AND LIGHTING. INSPECTOR TO VERIFIY CUSTOM LIGHTING LISTING AND WATTAGE.<<<<ADDITION TO EXISTING RESTAURANT WITH OUTSIDE DINING. NEW SERVICE, PANELBOARDS, AND CIRCUITS. FULL PLAN CHECK>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45157	12041-10000-01472	308 N AVALON BLVD	90744	15	027B205   102	7418024002	[Q]CM-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	33.77308	-118.26171	Plan check 20KW roof mounted photovoltaic system for hotel building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45158	19041-10000-03864	4212 N LANKERSHIM BLVD	91602	4	165B177   892	2423024044	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.14626	-118.36314	New Sprinkler Monitoring System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45159	11041-10000-08260	540 S SANTA FE AVE	90013	14	126A217   221	5164004002	M3-1, PF-1XL	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.04042	-118.23057	CHANGE FEEDERS TO ALUMINUM AND TENANT IMPROVEMENT ( FIRST TIME TENANT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45160	12041-20000-19283	5146 N TENDILLA AVE	91364	3	171B105   854	2168018060	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Finaled	10/03/2012 12:00:00 AM	ADDRESS	34.16294	-118.60156	Photovoltaic system on roof of SFD with service upgrade to 200 ampere bus and main, with PV monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45161	12041-10000-04412	621 S WESTERN AVE #105	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM	04/12/2012 12:00:00 AM		Permit Finaled	07/02/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	CHANGE OF USE OF 1ST FLOOR TENANT SPACE: FROM RETAIL TO BAKERY SHOP: first tenant into commercial space; on shell plans, conduits were stubbed out into tenant spaces; single tenant will occupy two spaces * 105 & 106 )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45162	19041-10000-00480	4322 S CENTRAL AVE	90011	9	114A209   338	5115033039	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.00518	-118.25582	ENERGY PLAN CHECK FOR A CHANGE OF USE FROM GROCERY STORE TO RETAIL STORE.  SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA 20,650-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45163	12041-10000-17245	119 E CULVER BLVD	90293	11	096B149   514	4116007031	[Q]C4-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	33.95798	-118.44957	Plan check for power and energy. Occupancy load is greater than 100. Tower 42 Restaurant. 2873 combined sqft (2175 indoor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45164	18041-20000-41876	889 S FRANCISCO ST	90017	14	129A207   342	5144023229	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.04769	-118.26404	TI to (E) commercial office spaces on levels B1, 1, and 3.  Plan check for energy - 348 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45165	12041-10000-17722	3352 W OLYMPIC BLVD	90019	10	129B193   297	5080002022	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.05243	-118.3109	CHANGE OF USE FROM (E) OFFICETO DENTAL OFFICE,FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45166	18041-20001-42544	6708 N NEVADA AVE	91303	3	180B101   162	2139007027	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.19218	-118.609	Revision to approved set of plans.  Relocation of equipment.  Plan check only. $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((PV1.  Install 15.275 kW roof mounted grid tied PV system.  (47) modules with (2) 7.6 kW rated string inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45167	14041-10000-17165	16625 W BOSQUE DR	91436	5	165B137   308	2291006020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.14776	-118.49516	PV1, INSTALL 10.455 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS.(41) MODULES: TRINA SOLAR TSM-250PA05.18(2) SOLAREDGE SE6000A-US-ZB-U AND SE3000-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45168	17041-10001-06209	10539 N OKLAHOMA AVE	91311	12	207B109   540	2706012009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.26207	-118.58665	$0 PERMIT FEE FOR SENATE BILL 1222 FROM 2012PC FOR PV SYSTEM. 11.5KW DC/ 7.6KW AC. PERMIT FOR POWER RELEASE FOR METER SOCKET. DWP METER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45169	18041-20001-48731	17015 W RAYEN ST	91325	12	195B133   203	2690008018	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	01/02/2019 12:00:00 AM	ADDRESS	34.23225	-118.50329	expeditepv1install roof mounted pv system sized 12.6KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45170	13041-10000-17091	2970-2980 N RIPPLE PL 1-56	90039	13	151-5A211 312	5442031043	(T)(Q)CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			06/27/2013 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.10734	-118.24886	New 56-unit condominium.  3-story building and 1 level of subterranean parking.  Power and energy plan check.  Variance required for separation of fire alarm from plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45171	13041-10000-17973	1026 W 34TH ST	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	PIN	34.02400284	-118.2895744	New fire alarm system for Uytengsu aquatic center at USC. 208 devices. 1 communcation device, 1 fire panel. 2 stories.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45172	15041-20000-36223	300 S GRAND AVE 2nd Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 17,838 sq. ft. Note: Building application has been created under 15016-10000-23504	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45173	14041-20000-17539	10807 N SAN FERNANDO ROAD	91331	7	207B157   293	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Reviewed by Supervisor	08/05/2014 12:00:00 AM	ADDRESS	34.26639	-118.42263	TI to (E) single-story commercial office building.  Plan check for Title 24 for changes to lighting system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45174	15041-10000-15290	200 WORLD WAY UNIT # 229	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	"T24 ONLY. INSTALLATION OF ILLUMINATED SIGNAGE NOT VISIBLE FROM ROW. COPY TO READ ""SEA lEGS"". TERMINAL 2. TOTAL AREA 7.13 SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45175	12041-10000-28870	18421 S HOOVER ST	90248	15	063B201   146	6121020906	PF	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM			PC Approved	01/24/2013 12:00:00 AM	ADDRESS	33.86594	-118.28587	NEW INSTALLATION OF 336KW GROUND MOUNTED PHOTOVOLTAIC SYSTEM FOR LAUSD BUS GARAGE. CANOPY, ONLY MODULES AND COMBINERS ARE CHANGED.   (PLAN CHECK ONLY. THE PERMIT WAS ISSUED UNDER: 11041-10000-26630)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45176	18041-10001-22128	1828 E CESAR E CHAVEZ AVE #4500	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.05014	-118.21571	SUPPLEMENTAL FOR PLAN CHECK FOR ENERGY ONLY - NO EMERGENCE GENERATOR PATIENT EXAM ROOMS ONLY - PLAN CHECK FOR TITLE 24 ONLY FOR NON HIGHRISE BUILDING- NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT FOR (E) MEDICAL OFFICE FOR SUITE #4500 - TOTAL AFFECTED AREA = 1592 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45177	16041-20002-33620	4438 W DON MIGUEL DR	90008	8	114B181   725	5027003005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.00575	-118.35161	"CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE NEW PV LOAD CENTER AND CONNECTIN POINT TO MSP. ""$0 permit fees due to senate bill 1222""PV1.  Install 15.2 kW AC (12.96 kW DC) roof mounted utility interactive PV system.  (54) modules with (2) 7.6 kW transformerless inverters with power optimizers."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45178	17041-20002-45995	1753 S VIRGINIA ROAD	90019	10	126B185   644	5071007062	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.04192	-118.33418	PLAN CHECK FOR DERATED MAIN BREAKER FROM 150A TO 175A ON 225A PANEL  - HOUSE LOAD CALCULATIONS = 150A. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 18.72KWNote: $0.00 permit fee due to CA Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45179	16041-20000-07495	20419 W STAGG ST	91306	3	189B109   987	2107014065	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	PIN	34.2109741	-118.57817286	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45180	15041-20000-00026	7435 N JASON AVE	91307	12	186B093   424	2027007019	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2015 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.2051	-118.63525	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.865 KW.(23) KYOCERA KY 2556(1) ABB PVI-5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45181	19041-20000-15879	1400 S BRINKLEY AVE	90049	11	129B137    38	4407007001	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.05353	-118.49586	PV1.  Install 10.80 kW roof mounted grid tied PV system.  (30) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45182	19041-20000-28702	8336 W MELROSE AVE	90069	5	141B173   494	5528015048	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.08342	-118.37151	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 1630 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45183	14041-10000-31674	10837 N RATHBURN AVE	91326	12	207B125    81	2715004027	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.26753	-118.533	PV1 roof-mounted 10KW system including (2) Solaredge SE5000, (43) REC260 module and power optimizers. permit of $2 per senate bill #2222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45184	12041-10001-03886	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.30237	-118.46212	DELTA 2 CHANGES TO THE APPROVED PLANS.  <<Ti in a cafeteria. New lighting, panel, and CKTs. EPC is for power and Energy>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45185	16041-10000-18152	10960 W WILSHIRE BLVD 810 & 820	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	TI OF 2 NEW SUITES, 810 AND 820. ALL WORK WITHIN 8TH FLOOR - PC FOR T24 ENERGY ONLY. NEW LIGHTING. OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45186	18041-10002-06389	8160 W MANNIX DR	90046	4	150A175   189	5556004019	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.10593	-118.37	"6/8/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA "" C "" CHANGES TO RELOCATE ENERGY STORAGE DEVICE INSIDE GARAGE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45187	19041-20000-51798	6600 N TOPANGA CANYON BLVD UNIT 45	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	08/26/2020 12:00:00 AM		Issued	08/26/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	TENANT IMPROVEMENT REMODEL TO AN EXISTING RETAIL. ADDING (2) NEW PANELS, LIGHTS, AND LOADS TO EXISTING 1200AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45188	10041-20000-14994	22554 W VENTURA BLVD #201	91364	3	171B097   246	2040033039	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1372.01	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM			PC Info Complete	08/05/2010 12:00:00 AM	ADDRESS	34.16731	-118.6184	Install new lighting in existing building of medical care.   Power plan check and permit under 10041-20000-16389.  Plan check for lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45189	14041-20001-27123	6642 N ORION AVE	91406	6	180B145   242	2234019014	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.19162	-118.47036	expedite per customer request.install roof mounted pv system sized 6.0kw interconnected with msp.(30) trina solar tsm-255 modules(30) power optimizers p300(1) solar edge 6000 inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45190	15041-10000-16360	12516 W OSPREY LANE #3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	33.97884	-118.41153	((((5/28/2015))))PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 3 SIZED 1.38KW INTERCONNECTED WITH MSP.PERMIT FEES UNDER APPLICATION NUMBER 14041-20000-19516	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45191	13041-10000-09113	7122 N AMIGO AVE	91335	3	183B121   233	2126006017	[Q]CR-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Apartment			04/09/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.20004	-118.53846	New fire alarm system for a new 2 story apartment bldg.  < 100 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45192	16041-20000-40947	10262 ANGEL LANE	91331	7	204B165   423	2537004033	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25726755	-118.40472332	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45193	14041-20000-03866	13159 W CHELTENHAM DR	91423	4	162B157   421	2385006033	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.14171	-118.42266	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.1 KW AC USING MICROINVERTERS USING STANDARD PLAN. USING ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45194	14041-20000-17182	23062 W SYLVAN ST	91367	3	177B097   144	2039010015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.18447	-118.62975	PV1.  Install 7.70 kW roof-mounted, utility-interactive PV system.  Microinverters.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45195	17041-10001-11390	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.10222	-118.32701	PC FOR LOST SET OF PLAN. THIS IS PLAN CHECK ONLY! PERMIT TO BE PAID UNDER MASTER. FULL PLAN CHECK INTERIOR AND EXTERIOR RENOVATION FROM GROUND FLOOR (1) TO ROOF (6) FOR EXISTING  HOTEL, NO CHANGE IN USE. EXISTING 2000 AMP SERVICE 120/208V 3PHASE 4WIRE. NEW DISTRIBUTION BOARDS BEING ADDED, NEW PANELS. 5 TYPICAL UNITS. NEW INDOOR/OUTDOOR LIGHTING. PANELS. AREA: 36,440. BLDG # 17016-10000-08652.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45196	13041-20000-03763	11345 W SANTA MONICA BLVD	90025	11	129B149   478	4261004013	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Info Complete	02/21/2013 12:00:00 AM	ADDRESS	34.04623	-118.44997	T24 lighting plan check for a veternrian clinic.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45197	16041-10000-10310	870 W MARTIN LUTHER KING, JR BLVD	90037	9	114B197   213	5019001031	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.01079	-118.28969	PV1 NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (31) CANADIAN SOLAR:cS6P-265P  MODULES AND (1)SOLAREDGE  INVERTER AT 7.6KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45198	16041-20000-31725	14675 W RINALDI ST D, E, & F	91340	7	213B149   125	2612015011	C2-1-CPIO	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.2813	-118.45299	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR RETAIL STORE. PARTITION WALLS TO SEPERATE INTO D, E AND F AND BATHROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45199	18041-10000-34797	4222 N VINELAND AVE	91602	2	165B173  1260	2366020002	[Q]C2-2D-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.03	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.1455	-118.37004	PLAN CHECK FOR TITLE 24 ONLY FOR - PROPOSED T.I. TO EXISTING HOTEL MEETING ROOM; WORK TO INCLUDE NEW FINISHES, NEW T-BAR CEILING, MINOR NON BEARING FRAMING TOTAL AFFECTED AREA 5121 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45200	17041-10002-42783	443 S SAN PEDRO ST	90013	14	127-5A213 105	5148011018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	11/19/2020 12:00:00 AM	ADDRESS	34.04477	-118.24374	UPDATE / REVISIONS TO PERMITTED SET OF CORE/SHELL PLANS.ORIGINAL PLANS HAD ALL LOADS AND DRAWINGSAND CALCULATIONS  FOR FUTURE LOADS WHICH ARE INCOPORATED INTO THIS PLAN REVIEW. SHEETS E302 SHOWING TYPICAL RESIDENTIAL UNITS AND E024 FOR RESIDENTIAL PANEL SCHEDULES ARE ADDED TO THE SET OF PLANS.CORRIDOR LIGHTING CIRCUITS ARE ADDED ((((((((PC FOR SERVICE UPGRADE FOR EXISTING COMM. BUILDING WITH DWELLING UNITS. (POWER ONLY)SERVICE SIZE RATED AT 2000A 120/208VSCOPE INCLUDES NEW SERVICE GEAR AND 2 RESIDINTIAL DIST. BOARDS.ALL DWELING UNITS PANELS TO BE UNDER A SEPERATE PERMIT AND ARE FOR REFERENCE ONLY!BUILDING APP#17016-10000-32478	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45201	18041-20000-44271	20319 W HEMMINGWAY ST	91306	3	189B113   685	2107025054	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.21399	-118.57602	PV1.  Install 11.22 kW AC roof mounted grid tied PV system.  (40) modules with 7.6 and 6.0 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45202	15041-10000-37652	700 S FLOWER ST #2526	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI, T-24 TO AN OFFICE SPACE IN THE 25TH FLOOR OF AN  (E) HIGH RISE BUILDING, THE BLOC.  EXISTING PANELS, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ.FT. 4029.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45203	18041-10000-21989	2029 S CENTURY PARK EAST 20th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Issued	06/14/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN EXISTING RESTROOMS ON THE 20TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45204	16041-20000-10989	9725 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.24687	-118.5363	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 88 STEAK HOUSE. 1308 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45205	19041-20000-13253	6217 N CALVIN AVE pv1	91335	3	177B117   357	2131018006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Issued	04/23/2019 12:00:00 AM	ADDRESS	34.18306	-118.55574	pv1install roof mounted pv system sized 7.6 KW AC with battery 5KW interconnected with msp.  this is an addition to an existing pv syste.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45206	15041-10000-22413	633 W 5TH ST 4TH FLOOR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM			PC Info Complete	07/27/2015 12:00:00 AM	ADDRESS	34.05099	-118.25468	T-24 TO AN (E) RESTAURANT BUILDING. SCOPE INCLUDES CHANGE OF FIXTURES IN THE DINNING AREA TO LED LIGHTING. TOTAL SQ. FT. 909	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45207	17041-20000-43625	7600 N BALBOA BLVD	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.2087	-118.50093	Plan check for energy only. New lighting (including emergency) for existing commercial building. Outdoor/parking area - 12,250sqft. Indoor bicycle parking/corridor - 565sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45208	11041-20000-03101	6109 N DE SOTO AVE 1st Floor	91367	3	177B105    43	2149005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	34.18151	-118.5908	Install general/emergency lighting in partial of 1st floor corridor and stair.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45209	13041-10000-02636	6303 N OWENSMOUTH AVE 11TH FLOOR	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Issued	03/26/2013 12:00:00 AM	ADDRESS	34.18474	-118.60182	NEW DISTRIBUTION BOARD 600A. 2 NEW SUBPANELS. NEW FEEDER CONNECTED TO EXISTING PANEL. 2 NEW BRANCH CIRCUITS. LOACTED ON 11TH FLOOR OF OFFICE SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45210	18041-10001-26724	10408 N BALBOA BLVD	91344	12	204B133    17	2684012038	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Approved	08/06/2018 12:00:00 AM	ADDRESS	34.25952	-118.50211	Expedite per applicant request.(((Plan check for a 50KW AC PV2 roofmounted system with (156) modules and (1) 50KW inverter interconnecting throuth the subpanel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45211	15041-10002-17791	101 S JAPANESE VILLAGE PLAZA MALL	90012	14	129A215   347	5161017022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.04935	-118.23977	12/09/2016 Changes to an approved set of plans. Changes include remove H1 Panel and relocate panel T1. {{{{{{PC FOR POWER AND ENERGY. TI FOR OFFICE. FIRST TIME TENANT. TOTAL AREA 4608 SQ FT.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45212	11041-10000-24555	7021 W HOLLYWOOD BLVD # 110	90028	13	147B181   115	5548003020	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.1017	-118.34273	CHANGE OF USE FROM FOOD COURT TO RESTAURANTNEW LOAD ADDED IS 277APLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45213	17041-20000-44256	22906 S FRAMPTON AVE	90501	15	045B197    67	7347018009	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	33.8178	-118.29945	PLANCHECK FOR POWER ONLY PER APPLICANTS REQUEST. SERVER ROOM IN WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45214	13041-10000-32754	1500 W PACIFIC COAST HWY BLDG G	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING G THIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45215	14041-10001-14694	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	33.74512	-118.26099	(Mr. Ysaguirre is the Master Plan Check)Revision to approved set of plan noted as Delta-1&2. Narrative of changes is attached to the new plan, with highlights as follow: (1) Revision in single line diagrm(2) Redefine area of classification(3) Revise Mini Power Zone conduit designation and routing<<PC FOR POWER. REPLACE 3 MEDUIM VOLTAGE EXISITING MOTORS, AND 2 MCC WITH SOME NEW MOTORS. FOR PORT OF LA, TERMINAL ISLAND.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45216	18041-20000-00994	6323 N LINDLEY AVE	91335	3	177B125   166	2124017003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.1843	-118.52745	permit fee $0.00 by state senate bill no.1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.725 KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45217	16041-20001-18363	6600 N TOPANGA CANYON BLVD System C	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	4/5/2018changes to an approved set of plans.  changes to downsize total system size to 2.0Mw.This is system C all changes are clouded. this is plan check only.(((Plan check for PV carport ground mounted system in Topanga Mall Parking Lot. System size:666kW with 3,071 modules and 20 inverters(33.3kW) This is system C.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45218	14041-20000-32968	3550 S TROUSDALE PKWY	90089	9	118-5A201   9	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.02094	-118.28463	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR USC DML LIBRARY. LUMINAIRE MODIFICATION IN PLACE. 45855SQFT, EMERGENCY LIGHITING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45219	14041-20001-01880	1179 N OBAN DR	90065	1	154-5A221 277	5475001009	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/02/2014 12:00:00 AM	ADDRESS	34.11688	-118.21768	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTMIZERS. TOTAL OF 16 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45220	15041-10003-33053	9254 N WINNETKA AVE BLDG C	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.23884	-118.57087	Changes to an approved set of plans. All changes are clouded under delta 9. Changes include revising electrical room layout for main service.Note: permit Fee are covered under PCIS#15041-10000-33053	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45221	17041-20001-02108	281 N BENTLEY CIR	90049	5	138B149    66	4366004018	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.07702	-118.45744	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45222	16041-10000-28769	700 S FLOWER ST # G740	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN RETAIL TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45223	16041-20000-27043	7350 W MELROSE AVE	90046	5	141B181   614	5526020001	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM			PC Approved	08/02/2016 12:00:00 AM	ADDRESS	34.08343	-118.35003	Plan check for Title 24 only. Project site is an existing commercial tenant space within a commercial building. Project scope is a tenant improvement. Total lighting area = 690 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45224	10041-20000-13354	15023 W CALIFA ST	91411	2	177B145   509	2243021016	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Public Safety Only			07/13/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Expired	01/23/2012 12:00:00 AM	ADDRESS	34.1777	-118.46043	Plan check for new fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45225	15041-20000-21180	12561 N COMETA AVE	91340	7	219B157   299	2513020026	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.29795	-118.42459	Installation of new roof mounted solar PV array.  Total system size = 6.45 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45226	12041-10004-12382	221 S GRAND AVE	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.05419	-118.2505	[[[[[[[[7/10/14  CHANGES TO APPROVED SET. ADDITION OF 2 SMOKE DETECTORS. DELTA 8 CHANGES ONLY]]]]]]]CHANGES TO APPROVED SET, PLAN CHECK ONLY. DETLA 7 CHANGES.  ADDING 1 POWER SUPPLY BPS10A, 3 SIGA CT2, 1 SIGA CR AND REMOVING 1 SIGA-278 PULL STATION AND 2 SIGA 2-PS SMOKE DETECTORS.(((CHANGES MADE TO APPROVED SET. DELTA-4 AND DELTA-5 CHANGES.))) 10/03/13(((CHANGES MADE TO APPROVED SET. CHANGING EST3 GENESIS TO WHEEL LOCK (SPEAKER STROBES.)))New fire alarm system for Broad Museum.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45227	15041-20001-18087	2245 W YOSEMITE DR	90041	14	160-5A221  43	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.13556	-118.21671	12/23/2015 Changes to an approved set of plans. Changes include revision of branch circuits for additional equipment in the deli area. All changes have been reflected onto the panel schedule for Panel D. All changes have been clouded and marked as Delta G. *****Previous Work Description*****Plan check for power and energy electrical distribution system rated 1,000A with new branch circuit for lighting and power equipment. Total area: 27,622 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45228	13041-10000-36227	400 W WORLD WAY CTA-T-4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	pc for power and energy. TI FOR CANOPY LIGHTING LAX. Terminal 4 CTA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45229	10041-10000-22258	1265 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM			Corrections Issued	11/16/2010 12:00:00 AM	ADDRESS	34.05194	-118.22564	Solar voltaic system installed on the roof of the building.  Consists of  7 modules,  7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45230	16041-20000-00499	3641 S WATT WAY 324, 326,-328, 330	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.02033	-118.28801	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 1,406 sq. ft. Not a hazardous location per applicant.Note: Building application has been submitted under 15016-10000-25826	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45231	15041-10000-23232	7500 N WHITSETT AVE	91605	2	186B165   260	2307022010	(T)(Q)M2-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.20663	-118.40513	PLAN CHECK FOR POWER FOR REPLACEMENT OF 600AMP SWITCH GEAR FOR VERIZON CELL SITE WITH NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45232	13041-20000-19997	24437 W INDIAN HILL LANE	91307	12	186B089   428	2031013058	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.20533	-118.65539	New 12.49kw PV system for a sf residence.  System is Ungrounded. NOTE TO INSPECTION: DERRATING MAIN CB TO 150AMP. PROVIDED LOAD CALC. USING #8 AT THE OUTPUT OF THE INVERTER TO THE SUBPANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45233	11041-10000-27179	2749-2755 W 15TH ST	90006	1	129B193  1514	5075011023	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	05/25/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.04555	-118.30175	PLAN CHECK POWER AND ENERGY FOR CHARTER MIDDLE SCHOOL. NEW 800A SERVICE, CKTS, LIGHTING, AND DISTRIBUTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45234	17041-20001-19596	7947 N ETHEL AVE	91605	2	189B161   445	2303026015	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.21538	-118.41631	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.10kW ungrounded system.(25) 350W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45235	16041-10000-30875	9118 N CREBS AVE	91324	12	198B121   765	2763021051	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Expired	10/12/2018 12:00:00 AM	ADDRESS	34.23601	-118.54398	PC FOR PV ROOF MOUNTED SINGLE FAMILY DWELLING. SYSTEM SIZE 5.25KW, INCLUDING :21 PANELS (SUN WORLD 285 MONO)21 MICRO INVERTERS (ENPHASE M250 -60-2LL-S22)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45236	16041-10000-20288	5820 S 3RD AVE	90043	8	108B189  1483	4005022006	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	33.98851	-118.32045	PV1, rooftop solar instllation 4.125 kW AC system.   (15) SW275,   (15) M250 Enphase	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45237	13041-20001-35453	6922 N ALDEA AVE	91406	6	183B133   690	2230002004	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.1963	-118.50824	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. SOLAR OPTIMIZER USED. TOTAL SYSTEM SIZE 5KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45238	10041-10000-19836	5125 S WESTERN AVE	90062	8	111B193  1459	5005029002		South Los Angeles				2324.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	03/12/2012 12:00:00 AM		Permit Expired	04/07/2014 12:00:00 AM	ADDRESS	33.9962	-118.30908	CONVERT (E) WAREHOUSE INTO SFD JOINT LIVE/WORK QUARTERS.  EXISTING BLDG HAS BEEN URM RETROFITTED (97016-30000-27521).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45239	14041-20000-28687	6530 W COMMODORE SLOAT DR	90048	5	132B173    37	5088009009	R2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			PC Approved	10/17/2014 12:00:00 AM	ADDRESS	34.06207	-118.37115	PV1.  Install 7.425 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45240	11041-20000-08025	16500 W SHERMAN WAY	91406	6	183B137    75	2225004049	[Q]C2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.00	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.20093	-118.49259	T.I. to existing space for Autozone.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45241	18041-10000-01602	5549 W SUNSET BLVD	90028	13	147A193    93	5544023024	C2-1	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.09826	-118.3111	TENANT IMPROVEMENT FORAN  EXISTING RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45242	18041-20000-45093	19400 W KILFINAN ST	91326	12	219B117    97	2701020029	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.29695	-118.55674	Plan check for a PV1 roof-mounted PV system. System size is 11.05 kWdc/10.16 kWac-CEC and consists of (1) 10 kWac rated inverter and (34) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45243	13041-10001-22883	13361 N GLENOAKS BLVD BLDG B	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.3146	-118.45921	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES CLOUDED ON FLOOR PLAN MARKED DELTA 1.  CHANGES INCLUDE DIFFERENT RTU AND AC UNITS WITH ADDITIONAL PLUGS.][][]FILE ALARM VARIANCES WILL BE FILED FOR THIS PC APPLICATION][][][]NEW HIGH SCHOOL BUILDING ADDITIONS ( 2 TOTAL- EACH HAS 27,354 SF & IS A REPLICATE OF THE OTHER) . FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW CHARTER HIGH SCHOOL. THIS APPLICATION IS FOR BUILDING B.  SINCE BOTH BUILDINGS ARE EXACT DUPLICATES OF THE OTHER, FEES WILL BE CHARGED BASED ON HALF OF THE TOTAL FOR BUILDING B, AND THE OTHER HALF WILL BE BASED OFF BUILDING C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45244	19041-10000-17927	103 S ROBERTSON BLVD	90048	5	138B169   372	4334001028	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.07508	-118.38391	T-24 PLAN CHECK FOR AN INTERIOR REMODEL AND CHANGE OF USE FROM RETAIL TO OFFICE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 3205 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45245	16041-10000-42237	3825 N MISSION ROAD	90031	1	136-5A227  10	5211011031	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			Reviewed by Supervisor	12/06/2016 12:00:00 AM	ADDRESS	34.07009	-118.19958	METHANE MITIGATION AND DETECTION SYSTEM (LEVEL 5) FOR A NEW 3-STORY HIGH SCHOOL . 22 FA DEVICE AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45246	15041-10000-03967	25500 S VERMONT AVE	90710	15	036B197   839	7413031022	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	33.79244	-118.29048	Installation of new fire alarm system in existing school building.  41 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45247	17041-10000-37836	14425 W FOOTHILL BLVD	91342	7	228B149   157	2502024***	QRD1.5-1, RD1.5-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.32176	-118.44848	TITLE 24 ONLY, RELACE OUTDOOR EXISTNG FIXURES WITH LED FIXURES, TOTAL SQUARE FOOTAGE 12900 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45248	16041-20001-25323	4365 S GLENCOE AVE	90292	11	105B153    82	4212004025	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	33.98574	-118.43849	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,432 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45249	13041-10000-17848	6332 S BRYNHURST AVE #     1-12	90043	8	105B185  1015	4006008018	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			07/08/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	33.98193	-118.33365	12 unit new apt builiding, 3 stories, ground level parking.requires fire alarm - variance will be provided. wood structure - type 5.  plan check AND PERMIT is for power and energy title 24 for common areas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45250	18041-10000-11491	4616 W DE LONGPRE AVE	90027	13	147B197   891	5542017033	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.0968	-118.29007	PC FOR ENERGY AND EM LIGHTING, SCOPE OF WORK INCLUDES CONVERSION OF WAITING AREAS TO UROLOGY OFFICES. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 936.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45251	18041-20000-16408	14902 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.2942	-118.45505	Plan check for PV roof mounted system, system size: 3.8 kW and 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45252	13041-10001-18939	1122 S GAYLEY AVE	90024	5	132B149   112	4363023030	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			11/21/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	34.05976	-118.44586	((((Supplimental application to an approved set of plans. Changes included the addition of 11 branch circuits to existing panels; 11/21/2014; all changes on this application are noted as Delta 16))))pc for power and energy. Methane Buffer Zone. fire alarm variance to be filed. MIXED USE PROJECT- 34 UNIT APARTMENT, RETAIL AND PARKING GARAGE. THE 2 BASEMENT LEVELS ARE OF TYPE I CONSTRUCTION W/ PARKING, THE 1ST STORY IS OF TYPE I CONSTRUCTION RETAIL/ENTRY TO RESIDENTIAL UNITS AND OFFICE ACCESSORY TO  RESIDENTIAL, STORIES 2-4 ARE RESIDENTIAL UNITS OF TYPE IIIA CONSTRUCTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45253	18041-10000-03229	11150 W SANTA MONICA BLVD 600	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	PC for T24 energy only. Installing new lights, receptacles, equipment and panels. Total area  B#18016-10000-01627. Total area is 15002 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45254	19041-10000-40333	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.03365	-118.24048	Power plan check for (16) fast electrical vehicle chargering station located in a parking structure. Scope includes (2) 800-Amps distribution and (2) level-2 EV charger.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
45255	11041-10000-15085	1149 S BROADWAY 5TH FL	90015	9	126A209   600	5139019900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.03859	-118.26015	REMODELING OF 5TH FL OF AN OFFICE BUILDINGPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKT; PERMIT FEE IS IN INSPECTION OF FEE PERIOD ;     GSD CONST FORCES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45256	09041-10009-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM			PC Approved	06/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans for the north  and south concourses at BW GATES ; ADDITIONAL CIRCUITS FOR VAVS, SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45257	16041-20000-41468												Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Plans on Hold	12/02/2016 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45258	14041-20001-24868	7006 S HOOVER ST	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.8KW INTERCONNECTED WITH house Panel.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45259	14041-10000-32296	2029 S CENTURY PARK EAST 21ST-22ND FLR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	Energy plan check for a commercial office T.I (21th and 22nd floor)  based on 2008-standard energy code. Building permit reference #: 14016-10000-12643	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45260	14041-10001-26820	9 E DUDLEY AVE	90291	11	109-5A141 122	4286030012	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM			PC Approved	03/24/2015 12:00:00 AM	ADDRESS	33.99418	-118.47975	changes to an approved set of plans.  changes include energy calculations and fixtures.  identification of panel voltage class.  all changes noted delta 1.Energy plan check for a store T.I  commercial building including indoor and outdoor. Total are is 1620 SQ feet. Plan check is based on 2008 standard due to building plan submited before July 1st.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45261	18041-10000-07475	15249 W VICTORY BLVD	91411	6	180B145   793	2235001024	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	34.18686	-118.4657	PC for T24 only for replacement of indoor-outdoor existing fixtures with LED fixtures for Chase bank. Total area Indoor  is 11866sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45262	16041-10000-15031	3777 S WEST BLVD	90016	10	117B181   311	5045003004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.01758	-118.34139	PV1. 6.76KW-DC ROOF MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY DWELING. 26 MODULES MODEL CANADIAN SOLAR- CS6P-260P. WITH 26 MICRO CONTROLLERS (EN PHASE M215-60-2LL-S22).	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45263	11041-10000-05860	2001 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	PIN	34.06587468	-118.19737837	FIRST TIME TENENTS IN A NEW CAFETERIA ON THE FIRST FLOOR.  PLAN CHECK IS FOR POWER & ENERGY. VARIANCE FORM WILL BE SUBMITTED FOR THE FIRE LIFE SAFETY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45264	12041-20000-25092	1550 S WESTWOOD BLVD	90024	5	129B153    92	4325020019	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM			PC Approved	12/13/2012 12:00:00 AM	ADDRESS	34.05306	-118.4396	PLAN CHECK FOR ENERGY ONLY. 1 STORY. 2758 SF. EXISTING OFFICE TI REMODEL.  <<Original sqft was miscalculated----true area is 3070sqft.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45265	17041-20000-15161	10435 W SANTA MONICA BLVD	90025	5	132B157   686	4326032031	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Issued	07/20/2017 12:00:00 AM	ADDRESS	34.05686	-118.42548	PLANCHECK FOR T24 ENERGY.  T.I at (e) office , install new interior stairway to connect 1st & 2nd fllor. 2214 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45266	11041-20000-07500	400 S HOPE ST 20th Floor	90071	9	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	T.I. for a high rise building.  Install general/emergency in corridor of 20th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45267	12041-20000-00989	1630 N NORTH MAIN ST	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	06/22/2012 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.06682	-118.22728	New roof mounted 211 KW PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45268	14041-10000-17261	2501 W WILSHIRE BLVD	90057	1	133-5A201  99	5141006007	C4-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.06034	-118.28055	REMODEL EXISTING OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45269	13041-10000-03789	18842 W EDLEEN DR	91356	3	168B121   274	2176025008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.15675	-118.54372	PV1 SINGLE STORY HOUSE 17 MODULES.  3.672 KW SYSTEM POWER {MODULES: REC245PE} {MICROINVERTER: ENPHASE M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45270	13041-20000-04272	5928 N VAN NUYS BLVD	91401	2	177A151   188	2245003001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.17836	-118.44838	Plan check for energy and emergency lighting. John the Band Music Studios.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45271	19041-20000-06866	8700 S PERSHING DR PV1	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	33.95471	-118.44097	PV2.  Install 23.36 kW DC / 21.34 kW AC roof mounted grid tied PV system.  (64) modules with (1) 20 kW rated string inverter.  Interconnecting with MSA-1.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45272	16041-20000-43133	12035 W WATERFRONT DR BLDG 2	90094	11	105B161  1201	4211011029	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	33.98233	-118.40556	Tenant improvement of commercial sales areas.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45273	13041-10000-07685	19600 S MAGELLAN DR	90502	15	057B197    34	7351034074	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	33.85319	-118.29278	Power and energy for 3-story office bldg addition to existing 1-story warehouse.  14,132 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45274	19041-20000-15088	2137 W FARGO ST	90039	13	145-5A209 349	5422021013	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.09123	-118.25668	PLAN CHECK FOR INSTALLATION OF 13.5 KWH TESLA POWERWALL BATTERY ENERGY STORAGE SYSTEM TO A EXISTING SFD WITH A EXISTING PV SYSTEM. SCOPE OF WORK ALSO INCLUDES A NEW 200A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45275	11041-10005-27025	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			Reviewed by Supervisor	09/04/2013 12:00:00 AM	ADDRESS	34.04661	-118.2324	REVISIONS TO PERMITTED SET OF PLANS-ADDING 50HP FIRE PUMP AND 3HP JOCKEY PUMP TO BE SUPPLIED FROM NEW 75KVA TRANSFORMER ;PROPOSED 6-STORIES MIXED USE BUILDING: RETAIL;APTS;LIVE/WORK UNITS;OFFICES;GARAGE;PORTION OF THE BUILDING IS 5-STORIES, TYPE IIIA, APTS OVER 1-STORY TYPE I GARAGE/RETAIL/OFFICE.OTHER PORTION IS 3-STORIES TYPE IIIA APTS OVER 3-STORIES TYPE I	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45276	12041-10000-30994	13862 N CRANSTON AVE	91342	7	228B153   100	2503020021	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.32415	-118.4347	PV1 plan check for Microinveter standard plan. Single family dwelling. 1 story unit. using Enphase M215 microinverters and REC 245 PE modules.  System size is 4.16 kw DC (17 Modules) and 3.672kw AC (17 Microinverters).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45277	14041-10000-15416	5333 W ZOO DR	90027	4	162B197     2	5593002905	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.14867	-118.28623	PLANCHECK FOR T24 ENERGY. LA ZOO JAGUAR EXHIBIT. 1700 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45278	13041-10001-33927	867 S WELLESLEY AVE	90049	11	129B141   624	4264017001	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2013 12:00:00 AM			PC Approved	12/24/2013 12:00:00 AM	ADDRESS	34.04583	-118.47528	][][ PLAN CHECK ONLY - CHANGES MADE TO AN APPROVED SET OF PLANS TO ACCOUNT FOR RELOCATION OF ELECTRICAL EQUIPMENT ][][PC ONLY FOR PV1. CHANGES OF ROOF LAYOUT AND REDUCTION OF MAIN BREAKER SIZE FROM 200 TO 175.ORIGINAL PC UNDER 13041-10000-27670. PV1 - ROOF-MOUNTED SOLAR INSTALLATION WITH 16 MODULES , USING M215 ENPHASE MICROINVERTERS, ON STANDARD PLAN IN 2-STORY HOUSE. TOTAL AC OUTPUT = 3.45KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45279	15041-10001-27973	6201 W HOLLYWOOD BLVD SUITE 116	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Info Complete	01/27/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	"01/22/16Changes to an approve set. Changes inlcude adding new load equipment to panel ""L"" and increasing the length of the feeder to 420ft. Note: original permit paid under PCIS#15041-10000-27973((((PC FOR ENERGY ONLY ON EXISTING COMMERCIAL (NAIL SALON) 1-STORY BUILDING. SCOPE INCLUDES NEW PANELS AND LIGHTING. TOTAL AREA IS 1558 SQ. FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45280	14041-20000-27039	888 W 6TH ST 15th Floor	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.05062	-118.25846	TI to (E) commercial office tenant space in existing commercial high-rise building.  Plan check for Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45281	14041-20000-22611	12280 N DERWENT AVE	91326	12	219B121    76	2820001026	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Closed	05/21/2015 12:00:00 AM	ADDRESS	34.29659	-118.54981	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSB.(21) CANADIAN SOLAR CS6P-250PX MODULES(21) SOLAR EDGE POWER OPTIMIZERS(1) SOLAR EDGE SE50000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45282	19041-10000-03679	12457 N GLADSTONE AVE STE H	91342	7	219B161   235	2525018059	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Issued	01/31/2019 12:00:00 AM	ADDRESS	34.29638	-118.41277	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45283	18041-20000-14334	6822 W PARSONS TR	91042	7	207B201    23	2553014002	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	9800.26	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.26631	-118.28268	Note: $0.00 permit fee due to CA Senate Bill 1222PC for 12.42kW(ac)/17.55kW(dc) system for SFD. Installing 54 modules with microinverters with combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45284	18041-10002-22747	591 N IRVING BLVD	90004	4	141B189   663	5523030021		Central				1924.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/29/2018 12:00:00 AM	ADDRESS	34.08149	-118.31884	Expedite per applicant request(((Plan check for a PV1 5.2KW AC roof mounted system with (17) modules and (1) 5.2KW inverter interconneting through the main service panel with center-fed connection.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45285	14041-20000-31140	139 S LAYTON DR	90049	11	135B145   274	4365004020	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.06823	-118.46894	PV1Install roof-mounted solar array on SFD. Interconnect at 400A MSP.System size: 5kW. Ungrounded system. Using 300W power optimizers.20 250W pv modules across 2 strings (10+10).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45286	15041-20000-33219	2975 N TIFFANY CIR	90077	5	156B149    11	4379034008	RE15-1-H-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.12813	-118.44633	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45287	13041-20000-09784	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Regut and install new electrical equipment in an existing high-rise office building.  Load is less than 400 amps per applicant (Subject to field inspection).  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45288	13041-20000-19213	10345 W OLYMPIC BLVD	90025	5	129B161   114	4319006052	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	PIN	34.05191674	-118.41856576	RENOVATION OF OFFICES. NEW LIGHTING AND NEW PARTITIONS. PC FOR T24 ENERGY ONLY. TOTAL AREA OF LIGHTING CALCULATION ABOUT 25415 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45289	15041-20000-18697	15234 W VALLEYHEART DR	91403	4	168B145    38	2263017009	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.16107	-118.46513	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE 6.55KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45290	18041-20000-04843	2414 E MICHIGAN AVE unit 3	90033	14	127-5A223  81	5180002023	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Closed	04/26/2018 12:00:00 AM	ADDRESS	34.0449	-118.20834	PV2.  Reinstallation of 2.25kw AC pv system interconnected with msp.this is system 3 of 3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45291	19041-10000-51319	11732 N ODESSA AVE	91344	12	213B137    56	2610020016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.28417	-118.49096	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION WHICH INCLUDES 18 MODULES (PANASONIC 330W), 18 OPTIMZERS (P400), AND 1 CENTRAL INVERTER (SE5000H-US) SYSTEM SIZE: 5.940 KW DC; 5 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45292	11041-20000-15617	4139 N KRAFT AVE	91604	2	162B169   113	2368021003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	11/09/2011 12:00:00 AM	ADDRESS	34.14362	-118.38019	Plan check new roof mounted Enphase Microinverter Photovoltaic System for single family dwelling. Modification for Enphase M215 to be installed prior to testing agency approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45293	16041-30000-17690	2838 S CRENSHAW BLVD	90016	10	123B185  1167	5051008016	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.02997	-118.3349	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is tenant improvement. Total lighting area = 3,048 sq. ft.Note: Building application has been created under 16016-30000-10077	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45294	15041-10000-01528	742 N HUDSON AVE 3-4	90038	4	141B185  1197	5533035***	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Expired	04/07/2017 12:00:00 AM	ADDRESS	34.08467	-118.33194	Install roof mounted solar array, interconnect with main panel. system size 1.53kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45295	19041-30000-43061	633 W 5TH ST 3230	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.05099	-118.25468	T-24, PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1857	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45296	17041-10000-04460	928 N LAS LOMAS AVE	90272	11	129B125   287	4420004012	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.0508	-118.53635	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.5KWdc / 9.8KWac. GENERATOR NOT PART OF SCOPE OF WORK. (35)MODULES-SOLARWORLD SW300 MONO(35)MICROINVERTERS-S280-60-2LL-X	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45297	15041-20000-30304	800 N STRADELLA ROAD	90077	5	141B149   144	4370003025	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			Reviewed by Supervisor	10/09/2015 12:00:00 AM	ADDRESS	34.08296	-118.45374	New single family dwelling (two story with basement). Plan check for power only. Adding new 1200A service. Double check if TITLE 24 is required for parking garage. NEW SINGLE FAMILY DWELLING (TWO STORY WITH BASEMENT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45298	14041-10000-32437	200 WORLD WAY # 235	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER AND ENERGY. TERMINAL 2 FRESH BROTHERS FAST FOOD (235). TI. TOTAL AREA 725 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45299	15041-10000-29742	5971 W VENICE BLVD MOB-4TH FL	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.03865	-118.37272	FALTERATIONS IN AN EXISTING OFFICE S SPACE: RELOCATING  AND ADDING NEW LUMINIARES;FUNCTIONS IN NEW AREA IS ONE EXAM ROOM, RECEPTION, AND OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45300	18041-10000-35864	8701 S BROADWAY	90003	8	096A203    56	6040019001	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	33.9586	-118.27846	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45301	17041-10000-05922	1541 S PALOS VERDES ST	90731	15	012B201   400	7456020017	R2-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Expired	10/03/2023 12:00:00 AM	ADDRESS	33.72984	-118.28153	PV 2520 W DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE. (9) MODULES: HANWHA Q-CELL  Q-PLUS BFR-G4.1 280(9)OPTIMIZERS-SOLAREDGE P300 (1) INVERTER: SOLAR EDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45302	13041-10000-29280	5456 S MCCONNELL AVE	90066	11	102B161    26	4211009031	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	33.97743	-118.41904	NEW FIRE ALARM SYSTEM WITH ADDITION OF 148 DEVICES AND 2 PANELS FOR A NEW CHARTER SCHOOL IN A 2-STORY BUILDING. NOTE: DISCARD APPLICATION UNTIL APPLICANT RETURNS WITH ALL REQUIRED INFORMATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45303	16041-20001-23921	14358 W MAGNOLIA BLVD 1-95	91423	4	171A151    50	2248009025	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			Reviewed by Supervisor	07/19/2016 12:00:00 AM	ADDRESS	34.16469	-118.44621	RSES expedited plan checkPV2.  Install 13.95 kW DC roof-mounted PV system.  (45) modules with (2) 6kW transformerless central inverters.  System 2 of 2 for this parcel.Zoning clearance for the property can be found under 16041-20000-23917	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45304	19041-20000-49196	10631 N LA CANADA PL	91040	7	207B185   448	2549015004	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.26131	-118.33916	PV1. INSTALL 10.37 KW DC PV SYSTEM WITH (34) NEW MODULES ADDED TO EXISTING PV SYSTEM . SCOPE OF WORK INCLUDES (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45305	12041-20000-07555	9725 N LAUREL CANYON BLVD	91331	6	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.20	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.24604	-118.41908	800 KW TEMP. GENERATOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45306	14041-10001-23608	2634 N ASTRAL DR	90046	4	153B177   169	5571022012	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.11767	-118.35744	expedited rses plan check per applicant requset.<<pv1, install 17875 kw dc roof-mounted  solar array on a house, interconnect with main service panel, micro inverter(65) modules: sunmodule  plus sw 275 mono(65) microinverters: enphase m250>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45307	15041-20000-02389	14340 W GRAMMAR PL	91402	6	192B153   126	2638020001	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.22605	-118.44551	Roof mounted PV system total 6KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45308	15041-10000-16236	900 N CAHUENGA BLVD SUITE B	90038	13	144B185  1190	5533019012	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.0873	-118.32862	TENANT IMPROVEMENT TO (E) OFFICE SPACE:  (PLAN CHK S FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45309	16041-10000-22997	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Closed	04/16/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	Temporary power for a footbal stadium. service size 2000 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45310	17041-10001-07299	835 W JEFFERSON BLVD 7J	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 4 ON PLANS. UPDATED LIGHITNG LAYOUT AND T24 FORMS. REVISED A COUPLE OF CIRCUITS TO REFLECT AS BUILT. NO OTHER CHANGES. PC ONLY - PERMIT COVERED UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45311	18041-20000-07567	12669 N ENCINITAS AVE	91342	7	219B141    70	2604035027	[Q]CM-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.29989	-118.47409	Plan check for power and energy. Project site is an existing single-story commercial building. Project scope is a change of use from school to clinic and a tenant improvement. Work includes an existing utility service and existing distribution panels with all new loads and new subpanels. A Total lighting area = 130,912 sq. ft.Note: Building application has been generated under 18016-20000-04064	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45312	19041-20000-48466	15541 W MARILLA ST	91343	7	201B145   400	2656001040	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	34.24745	-118.47144	Plan check for a PV system, system includes 24 modules with a micro inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45313	18041-10000-24210	1728 W 84TH ST	90047	8	097-5A193  56	6034024010	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	33.9626	-118.30786	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES PV AND DC ESS INSTALLATION WITH 13 MOUDULES, OPTIMIZERS AND CENTRAL INVERTER.PV SYSTEM SIZE 4.55 KWDC/7.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45314	17041-20000-25106	9841 N AIRPORT BLVD 5th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Info Complete	07/25/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  scope of work in the corridor and r4estrooms in the 5th floor only.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45315	17041-10000-05268	5222 S WESTERN AVE	90062	8	108B193  1508	5003012004	C2-1VL, [Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.99437	-118.30876	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 25,325.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45316	19041-20000-21364	9201-9215 N CRANFORD AVE	91331	6	198B161   717	2629027071	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.2366	-118.41261	Change of use from warehouse to indoor nursery.  (E) 3000A 480Y/277V 3ph-4w service with new distribution and loads.  Plan check for power and energy.  Building permit under 19016-10000-16825.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45317	11041-20000-05056	19801 W NORDHOFF PL #109	91311	12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	03/15/2011 12:00:00 AM		Permit Finaled	03/23/2011 12:00:00 AM	ADDRESS	34.23568	-118.56464	T.I. to existing warehouse.  Install general/emergency lighting in office and corridor area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45318	18041-20000-47452	11550 W SANTA MONICA BLVD	90025	11	126B149   128	4261013001	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			12/14/2018 12:00:00 AM			PC Info Complete	12/14/2018 12:00:00 AM	ADDRESS	34.04491	-118.45296	Plan check for Title 24 for existing retail space T.I. Total area: 1400 sq ft.Plan check only, permit pulled under 18041-20000-44232B#18016-40000-35088	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45319	18041-20000-48175	555 S MATEO ST Bldg 2-1ST FLR	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	01/02/2020 12:00:00 AM		Permit Finaled	12/29/2020 12:00:00 AM	ADDRESS	34.03943	-118.23302	First time tenant to commercial office space.  First floor of Building 2. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45320	19041-10000-23976	13434 W HERRON ST	91342	7	225B157   249	2510014001	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/06/2019 12:00:00 AM	ADDRESS	34.31586	-118.42544	NEW ROOF MOUNTED 3.7 KW (DC) PV SYSTEM WITH 13 PV MODULES WITH ENPHASE MICRO INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45321	17041-10000-18745	8500 W BEVERLY BLVD Ste 675	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.07587	-118.37754	Title 24 plan check.  Installation of new wall mounted neon sign lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45322	14041-20001-20207	9221 N ARLETA AVE	91331	6	198B157   732	2625010002	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM			PC Approved	11/04/2014 12:00:00 AM	ADDRESS	34.23746	-118.42148	EXPEDITE FEESPV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 102.6KW AC. USING 9 CENTRAL INVERTERS. WITH 468 DC MODULES. CONNECT TO 208 3 PHASE LOAD SIDE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45323	19041-20001-00470	9400 N BURNET AVE #119	91343	7	198B145   103	2656021106	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Issued	02/11/2019 12:00:00 AM	PIN	34.2413442	-118.46253399	2/11/2019changes to an approved set of plans.  changes to add (2) modules panasonic HIT VBN330SA16 to an existing pv system.   ((((PV1.  Install 5.94 kW roof mounted grid tied PV system.  (18) modules with 5 kW rated string inverter.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45324	19041-10001-18237			4	135B181   343	5507008015	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM			PC Approved	11/05/2019 12:00:00 AM	PIN	34.06727154	-118.34368081	SUPPLEMENT TO T-24, CHANGE OF AN APPROVED SET.  AREA OF SCOPE 8443 SQ.FT. PERMIT FEES UNDER ORIGINAL PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45325	10041-10000-19744	800 N ALAMEDA ST	90012	14	132A215   188	5409023054	ADP, [Q]M3-1	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	03/23/2011 12:00:00 AM	ADDRESS	34.05494	-118.23752	PROPOSED TENANT IMPROVEMENT FOR STARBUCKS COFFEE SHOP INSIDE UNION STATION; CHANGE OF USE FROM RETAIL TO RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45326	11041-20000-21701	8153 N SAN FERNANDO ROAD	91352	6	189B173    40	2409002004	[Q]C2-2L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Expired	11/26/2013 12:00:00 AM	ADDRESS	34.21852	-118.36847	Revisions to 11041-20000-16874Add panel , AC-units, lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45327	15041-10003-29087	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Issued	10/11/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	DELTA  6 CHANGES TO PERMITTED SET OF PLANSCHANGES ON THE THIRD LEVEL IN FUTURE TENANT SPACE; LIGHTING IN PUBLIC AREAS; NEW ESCALATORORIGINAL PERMIT APPLICATION IS 14041-10000-09802	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45328	12041-10000-14647	4500 W LOS FELIZ BLVD	90027	4	150B197    26	5590003039	C4-1D, R3-1	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	34.11156	-118.28786	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TI AT EXISTING RESTAURANT. LESS THAN 99 OCCUPANTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45329	15041-20000-36184	1465 W 3RD ST	90026	13	133-5A207 247	5153027004	C2-1	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Issued	10/28/2015 12:00:00 AM	PIN	34.05935752	-118.26357841	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 1220 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45330	18041-10000-31161	10630 N SEPULVEDA BLVD	91345	7	207B145   393	2649011043	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			Verifications in Progress	10/10/2018 12:00:00 AM	ADDRESS	34.26357	-118.46694	***VOID, PLAN  CHECK AND PERMIT PULLED UNDER 18041-10000-48205New PV2 rooftop solar system on the (E) Occupational Medical Building. (154) modules, (2) central inverters total 50 kW AC system, (2) 30 kVA step-down transfromers from 480/277V - 240V, system interconnects to (2) separate existing subpanels	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45331	16041-30000-33677	9364 W BEVERLYCREST DR	90210	4	147B165   442	4352011017	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM			PC Approved	11/13/2017 12:00:00 AM	ADDRESS	34.0967	-118.40303	Plan check for New Single Family Dwelling(SFD) 2 story house. 600A 120/240V Service. Electric permit was paid as combo permit under 15010-10000-01384.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45332	14041-10000-16401	630 S MASSELIN AVE	90036	4	135B181   866	5508014037	[Q]C2-1-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			06/19/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.06378	-118.35237	PLANCHECK FOR POWER AND ENERGY( COMMPN AREA: LEASING OFFICE AREA ). UPGRADE EXISTING APARTMENT BUILDING TO PROVIDE INDIVIDUAL WASHERS AND DRYERS IN EACH APARTMENT UNIT ALONG WITH PANELS ; TI ON FLOORS 1-4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45333	12041-10000-25250	2027 N VINE ST	90068	4	151-5A187 426	5576019046	R2-1XL	Central	Hollywood	Hollywood United	YES	1895.00, 1896.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.10751	-118.32682	PV 2 FOR CONVENT HOME. INSTALL ROOF MOUNTED SOLAR & INTERCONNECTED TO MAIN SERVICE PANEL 7.8 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45334	16041-20000-42194	19538 W VENTURA BLVD	91356	3	174B117   324	2164016027	C2-1VLD, P-1VLD	South Valley	Encino - Tarzana	Tarzana	Yes	1394.02	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.17252	-118.55901	ti to an existing commercial space.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 1196	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45335	16041-20001-12900	11540 W BLIX ST	91602	2	168B169   600	2354016053	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	PIN	34.1564198	-118.38356444	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. Each module has a 300W power optimizer.(36) 270W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45336	14041-10000-00826	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM			Not Ready to Issue	06/12/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	New fire alarm system for Runway at Playa Vista, BLDGS 1-4, A, B, and Stage 2 A & B.  2,373 devices, 4 FACPs, and 4 control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45337	16041-10000-30254	5840 S VAN NESS AVE	90047	8	105B189    31	6001004013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	10/05/2016 12:00:00 AM	ADDRESS	33.98783	-118.3175	Addition of  a new roof mounted PV solar system to an exsiting system. The new system is rated at 2.5 kw (microinverter: M50-60-2LL). ** existing system is rated at 3.0 KW (IG 3.0) as provided by applicants. Permit was paid under application 16041-90000-18486	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45338	15041-10000-37711	5235 N TOPEKA DR	91356	3	171B121   300	2163024002	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.1656	-118.54667	PV1, INSTALL 10.80 KW DC  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (40) MODULES:  MITSIBISHI PV-MLE270HD(1) INVERTER: SOLAREDGE SE11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45339	18041-10000-40397	5555 W WILSHIRE BLVD	90036	4	135B181   895	5508012038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.0625	-118.34962	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45340	19041-20000-51631	976 S CARMELINA AVE	90049	11	126B141   106	4264021023	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM	ADDRESS	34.04442	-118.47331	INSTALL (1) TESLA WALL MOUNTED BATTERY ON EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45341	16041-20003-27515	1451 E 4TH ST	90033	14	127-5A219 339	5172020009	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Approved	07/13/2017 12:00:00 AM	ADDRESS	34.04249	-118.22532	Revisions to approved set of plans.  Minor power and lighting revisions to reflect changes in architectural layout of tenant spaces.  (((Plan check Power and energy in existing building existing panels core and shell  load exceed 400A. Total area: 35,718 sq ft.Building permit filed under 15016-20000-25915.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45342	16041-20001-17384	510 S ARDMORE AVE	90020	10	135B193   700	5502017019	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	06/01/2016 12:00:00 AM	ADDRESS	34.06499	-118.30141	EXPEDITE PER APPLICANT REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 48KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45343	16041-20001-37197	945 S HUDSON AVE	90019	4	132B185   486	5090006009	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.05779	-118.33477	***VOID***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45344	19041-20000-15704	6650 N VAN NUYS BLVD	91405	6	180B149   241	2237001010	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.19215	-118.44845	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45345	16041-10000-21088	400 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.04446	-118.25616	"Restaurant remodel on existing commercial space. Change of use from nightclub/restaurant to a restaurant ""Shake Shack"". This is full plan check, total affected area: 2,767 sq.ft((B# 16016-40000-11947))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45346	10041-10000-10755	2201 S WESTWOOD BLVD	90064	5	126B157   400	4322002023	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	ADDRESS	34.04357	-118.43169	TI - CHANGE OF USE FROM RETAIL TO NEW CHASE BANK BRANCH. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45347	19041-10000-35120	7633 N VARNA AVE ST. A	91605	2	186B157    92	2301014027	[Q]CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.20991	-118.42485	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS (INDOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45348	11041-10000-25029	2959 N GLENDALE BLVD	90039	13	153A207    93	5435028031	[Q]C1.5-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.1147	-118.26485	PLAN CHECK 30KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45349	15041-20000-19422	7221 N VAN NUYS BLVD B3	91405	6	183B149    24	2218024015	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.20192	-118.44901	Title 24 plan check only.  Total area = 2,407 sq. ft.Change of use from retail space to office.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45350	18041-20000-08278	4150 N HAYVENHURST AVE	91436	5	165B137   429	2291013014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.14634	-118.49729	permit fee $2.23 by state senate bill no.1222Plan check for a PV1 roof-mounted PV system. System size is 13.8 kWac and consists of (43) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45351	19041-10000-18326	15615 W CASTLEWOODS DR	91403	5	159B141   257	2280015017	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.13334	-118.47412	$0 fee due to AB1414 ordinance.PC FOR PV-1. SYSTEM SIZE 17.01KWDC/15.56KWAC. SCOPE OF WORK 54 MODULES (Q CELL Q.PEAK DUE-G5 315W) W/54 OPTIMIZERS (SOLAREDGE P320), 2 INVERTERS (SOLAREDGE SE10000H-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45352	15041-20000-03822	3072 N ST GEORGE ST	90027	4	153A205   135	5434020005	R1-1	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2015 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Expired	03/03/2017 12:00:00 AM	ADDRESS	34.1125	-118.27273	pv1install roof mounted pv system sized 3.8kw interconnected with msp.(17) canadian solar cs6p 250/235 modules(1) solaredge se3800 inverter tl	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45353	13041-10000-35506	11100 W SANTA MONICA BLVD # 850	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLAN CHECK FOR T24 ENERGY ONLY. TI TO INCLUDE 2 EXTRA OFFICES, NO CHANGE OF USE. HIGH RISE . SUITE 850 ON THE 8TH FLOOR.  3717.9 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45354	16041-20000-21538	9901 W WASHINGTON BLVD 106	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.02174	-118.39786	TI TO A CHANGE OF USE FROM RETAIL TO RESTAURANT.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45355	17041-10000-19428	16360 W ROSCOE BLVD	91406	6	192B137   317	2689023001	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.22113	-118.4895	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45356	16041-10001-10543	4865 N LOUISE AVE	91316	5	168B133   205	2290002003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.15843	-118.50997	EXPEDITE PER APPLICANT REQUEST.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 29.430KWdc / 25.4KWac.(90)MODULES-SPR-327NE-WHT-D(4)INVERTERS-2 SMA SB7700TL-US-22 AND 2 SMA SB5000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45357	14041-20000-01733	10454 N MONTGOMERY AVE	91344	12	207B141   760	2668018020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.26072	-118.48146	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.25KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45358	11041-10003-18357	6750 W SANTA MONICA BLVD	90038	4	144B185   764	5532027016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.09057	-118.33767	tHE PERMIT 11041-10004-18357  WAS WITHDRAWN UPON CUSTOMER REQUEST. 9-5-12  AND 11041-10003-18357 IS THE RPLACEMNT. M.ZANDI EPC  ((((   mods to previously approved set , , usinf the lighting and title 24 from 11041-10000-18357 ,z andi using power from 11041-10001-18357. total combined to one set of pland.   8-9-12 ))))))))))))))))))))))))) ADDITION OF SECOND LEVEL OFFICE AND EXTERIOR DECK. REPLACE EXISTING WINDOWS/DOORS.(((((((((( CHANGES MADE TO PREVIOUSLY APPROVED SET ADDITION OF NEW CKTS AND NEW PANEL AND TITLE 24.))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45359	15041-10001-07306	10900 W WILSHIRE BLVD PLAZA LEV-LOBBY	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.05848	-118.44419	CHANGE TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 REVISION. CHANGE TO HOME RUN DESIGNATION. CHANGE EXIT SIGN TO DUAL CIRCUIT TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45360	16041-20001-22381	1200 S SANTA FE AVE 1ST FLOOR	90021	14	123A217   315	5166007011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM			PC Approved	07/20/2016 12:00:00 AM	ADDRESS	34.02944	-118.22979	07/20/2016 Changes to an approved set of plans. A split-bus panel has been turned into (3) separate panels. No changes in the amount of load. All changes have been clouded and marked as Delta 1. Permit fees shall be covered under master application.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT FOR A NEW OFFICE SPACE.  1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45361	16041-10000-08861	15303 W VENTURA BLVD SPACE P10	91403	4	168B145   821	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Closed	07/06/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	T-24, PC for energy only. TI on (E) Restaurant inside the Sherman Oaks Galleria - SPACE P-10. Total area: 2,691 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45362	16041-10000-04741	3165 W 6TH ST	90020	13	135B197   953	5077003013	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.06383	-118.29074	Install new METHANE mitigation/Detection for an Ihop Restaurant. (1) Panel  (14) devices. REDUCE DEVICE PRICE OK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45363	14041-20000-22594	9000 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Expired	04/03/2017 12:00:00 AM	ADDRESS	34.23391	-118.55337	parking lot lighting energyb plan check only, existing pole lights replace bulbs with LED only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45364	19041-20000-08761	12701 W HORTENSE ST	91604	2	168B161   712	2362022016	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.15501	-118.40964	NEW TESLA POWERALL 5KW ENERGY STORAGE SYSTEM, CONNECTED TO EXISTING SFD ROOF MOUNTED PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45365	10041-20000-06310	6710 N KESTER AVE 1st floor	91405	6	180B149   177	2236004024	[Q]CR-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	12/10/2010 12:00:00 AM	ADDRESS	34.19266	-118.45723	first floor tenant imporvement in medical office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45366	13041-20000-15582	18700 W VENTURA BLVD #150	91356	11, 3	174B121   811	2161026002	(Q)C2-1VL, C2-1VL, R1-1	South Valley, West Los Angeles	Encino - Tarzana, Palms - Mar Vista - Del Rey	Mar Vista, Tarzana		1394.01, 2719.02	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Issued	07/16/2013 12:00:00 AM	ADDRESS	34.17045	-118.54081	original application for energy under 13041-10000-05051. this application is for full plan check for first time tenant. TI OF EXISTING RETAIL SPACE FOR RETAIL. NO CHANGE OF USE. PC FOR T24 ENERGY ONLY. TOTAL AREA 1261 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45367	13041-20001-32869	12641 W PRESNELL ST	90066	11	105B157   533	4221027028	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	33.98392	-118.42249	((Expedite fees))PV1 CENTRAL INVERTER SYSTEM WITH FOUR STRINGS. TOTAL SYSTEM SIZE 9.36KW. 36 PANELS AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45368	16041-10000-25942	1149 S HILL ST 600 SE	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.03926	-118.26099	PC FOR TITLE 24, ENERGY ONLY  3352 SQFT.6TH FLOOR SUITE 600  SE (SOUTH EAST)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45369	15041-10000-39848	404 S FIGUEROA ST 3RD Floor	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM			Corrections Issued	11/25/2015 12:00:00 AM	ADDRESS	34.05326	-118.25596	TI TO 3RD FLOOR MEETING ROOM. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45370	13041-10000-29281	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM			PC Approved	10/21/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	Title 24 for a 27th floor of a high rise bldg TI for office. no emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45371	17041-10000-16217	105 E I ST	90744	15	030B205   106	7423005010	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.78137	-118.26207	PC for energy only. Outdoor Title-24. Removing existing fixtures and adding new LED lights. Area: 7325sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45372	17041-10000-05975	16216 W KITTRIDGE ST	91406	6	180B137   338	2233032014	[Q]M1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.1901	-118.48664	Plan check for Title 24 only in existing space, remove Metal Halide Outdoor lighting fixtures and replace with new LED Fixtures. Total area: 5,700 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45373	13041-10000-02996	1900 S CENTRAL AVE	90011	9	120A211    84	5129003037	C1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.02412	-118.25057	New single story restaurant building. Power and Energy (indoor and outdoor) full plan check. Service size: 800A. Indoor sqrft: 5,037. Outdoor sqrft: 44,250.Variance to separate fire alarm plans filed on 12/3/2013.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45374	10041-10000-03608	777 E 10TH ST #103	90021	9	124-5A211 244	5132002028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	03/05/2010 12:00:00 AM		Permit Finaled	03/30/2010 12:00:00 AM	ADDRESS	34.03437	-118.24974	Plan check power and energy for first time tenant, unit #103. Permit is for new ckts and work on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45375	19041-10000-35073	3151 E 12TH ST	90023	14	118-5A223 102	5169005012	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.0184	-118.21159	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45376	13041-10000-34669	720 N EUBANK AVE #B	90744	15	030B209   247	7424011034	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	33.77921	-118.25429	Remove HID light fixtures and replace with new fluorescent fixtures in existing retail space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45377	15041-20002-26399	11501 W DUQUE DR	91604	2	156B169   116	2381022002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.12715	-118.38472	CHANGES TO AN APPROVED SET. RELOCATING PV MODULES ON ROOF. PERMIT PAID UNDER PCIS#15041-20000-26399/E15VN02221(((Installation of new roof mounted solar PV array.  Total system size = 11.07 kW.  Central inverter system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45378	16041-20000-16812	1012 S KENISTON AVE	90019	10	132B185   663	5083003015	R2-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.0565	-118.3362	Plan check for PV roof mounted system. System size: 6.0kW with 1 inverter(6.0kW) and 26 modules. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45379	16041-10000-40768	2824 E BLANCHARD ST	90033	14	129A227   141	5178009032	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.04835	-118.1983	PV INSTALL 3526 W AC ROOF-MOUNTED FOR A DWELLING HOUSE.(14) HANWA Q-CELL, Q-PLUS-G4 280W(1) INVERTER: SOLAREDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45380	14041-20000-03942	13606 W ROSCOE BLVD P-7	91402	6	192B157   678	2213021013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.22145	-118.42935	TI energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45381	13041-10000-15554	3183 W WILSHIRE BLVD UNIT 174	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.06196	-118.29111	Retail space TI for unit #174.  Space being converted from retail shop to MTA ticketing station.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45382	17041-10000-01492	523 W 6TH ST 5TH FLOOR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	PIN	34.04872199	-118.25441618	PC FOR ENERGY. T.I ON 5TH FLOOR CORRIDOR IN  AN EXISTING HIGH RISE BUILDING. CONNECTED LOAD <400A, TOTAL AREA 1479 SQ FT. B#15016-10000-09811	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45383	16041-20001-34128	6600 N TOPANGA CANYON BLVD 9003	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM			PC Approved	02/08/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Revisions to previously approved set.  Revisions to lighting system/case configuration.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45384	16041-20001-38183	1201 E 7TH ST	90021	14	126A213   652	5147034016	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			10/27/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	34.03762	-118.24209	Expedited plan check fee per applicant request.  PV2.  Installation of 10.0 kW AC roof-mounted grid-tied PV system on 3-story apartment building.  (33) modules with (1) 10kW rated central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45385	13041-20000-06581	16501 W VENTURA BLVD # 300	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.1578	-118.49275	T-24 lighting and emergency lighting plan check for suite 300.  The installed load is less than 400 amperes.  The contractor shall provide panel schedules at time of inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45386	15041-10000-01358	200 WORLD WAY TERM 2-DEPT LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 DEPT  LEV 1  SPACE 226PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45387	19041-20000-37561	1350 N IVAR AVE	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	03/10/2020 12:00:00 AM		Permit Finaled	09/30/2021 12:00:00 AM				CHANGE OF USE TO A THEATER TOTAL CONNECTED LOAD OVER 400AMP. PROVIDE NEW PANELS, EQUIPMENTS, AND LIGHTS WITH A TOTAL SCOPE OF WORK AREA IS 17,392-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45388	15041-10000-23718	1142 S ABBOT KINNEY BLVD	90291	11	108B145  1189	4238003021	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	33.99131	-118.46928	T 24 FOR AN EXISTING COMMERCIAL BUILDING . SCOPE INCLUDES NEW SERVICE, PANEL, RECEPTACLE, AND LIGHTING. fTOTAL  AREA = 1030 SQ. FT.  PERMIT FEES HAVE BEEN PAID UNDER  PCIS# 15041-10000-19208  PCAM #X15LA11113.  PER JOHN HUA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45389	12041-20000-25389	22333 W SHERMAN WAY	91303	3	183B101     5	2023028044	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	11/14/2012 12:00:00 AM	ADDRESS	34.20119	-118.61325	T-24 LIGHTING PLAN CHECK FOR ADDITIONAL LIGHTING TRACK IN SALES AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45390	19041-10000-45777			4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM			PC Info Complete	11/07/2019 12:00:00 AM	PIN	34.10275173	-118.28080382	permit paid and pulled under 19041-90000-44186T-24 PC. TOTAL AFFECTED AREA 277sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45391	19041-20001-36589	22130 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.18629	-118.60968	Expedite per applicant request. Plan check for PV roof mounted system, PV system size: 27.405KW DC, 24.4KW AC CEC with 63 PV Modules and 2 inverters(9KW and 14KW). Note: This is 12 buildings in 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45392	18041-10000-01266	1508 N LACHMAN LANE	90272	11	135B121    50	4420035004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM			Reviewed by Supervisor	01/24/2018 12:00:00 AM	ADDRESS	34.06302	-118.54979	PC FOR NEW ROOFTOP SOLAR SYSTEM CONSIST OF 43 MODULES (SOLAR CITY SC325) AND 2 INVERTERS( DELTA SOLIVIA 6.6TL @ 6.6KW & DELTA SOLIVIA 5.2TL @ 5.2KW ) .  SYSTEM SIZE IS 13.975KWdc and 11.8KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45393	14041-20000-08014	24101 S FRAMPTON AVE	90710	15	039B197    42	7439011038	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM			Reviewed by Supervisor	04/14/2014 12:00:00 AM	ADDRESS	33.80503	-118.29925	"PLANCHECK FOR POWER. SERVICE UPGRADE FROM TWO 800 AMP SERVICE TO ONE 4000AMP SERVICE. TENANT IMPROVEMENT.""Comply with department order effective date 5/14/2013.  Permit will expire 30 days from issuance date.""INVESTIGATION FEE HAS BEEN ADDED"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45394	16041-30000-00256	1055 S BROXTON AVE	90024	5	132B149    60	4363024006	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.06147	-118.44643	Title 24 plan check only.  Total area = 1,250 sq. ft.     T.I. to existing restaraunt space.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45395	19041-30000-15827	6725 W SUNSET BLVD 4th Floor	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.09814	-118.33717	Plan check for Title 24 only. Project site is the common area corridors on the 4th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,052 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45396	16041-20000-34474	4550 N VAN NUYS BLVD Suite E	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	05/16/2017 12:00:00 AM		Issued	05/16/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	Plan check for energy only. TI to restaurant - Burger Lounge. New lighting (including emergency) - T24. 1,818sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45397	15041-10000-13862	7060 W HOLLYWOOD BLVD 2ND FL	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.10137	-118.34379	TENANT IMPROVEMENT IN COMMERCIAL BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45398	12041-10000-29025	6950 N LENA AVE	91307	3	183B097   624	2026024009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.19601	-118.62621	PV1 ROOF MOUNTED SOLAR INSTALLATION IN A ONE STORY HOME. SYSTEM SIZE IS 7.656 KW. TOTAL OF 36 MODULES IN THREE STRINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45399	16041-10000-27792	4151 W PROSPECT AVE 5TH FLR	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM			Corrections Issued	08/05/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	TITLE 24 ON EXISTING BUILDING WITH TI WORK ON 5TH FLOOR. TOTAL SQ. FT. = 6606	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45400	13041-10000-06052	3811 N MOUND VIEW AVE	91604	2	162B165   702	2369012003	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.1397	-118.39514	PV1 FOR 2 - STORY HOUSE.  AC MODULES.   3 STRINGS, 41 MODULES TOTAL.  {41 MODULES: SUNPOWER E18/225 AC}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45401	10041-10000-13336	7135 N HAYVENHURST AVE	91406	6	183B137    90	2225004042	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.00	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	03/25/2011 12:00:00 AM	ADDRESS	34.20027	-118.49257	Install a 600 ampere generator lug box, 3 pole manual transfer switch, new distribuition board, to supply two new panels and an existing single phase dsistribution boartd.  No change in the DWP service drop to the building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45402	13041-10000-13421	980 N WESTERN AVE #C	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	ADDRESS	33.7515	-118.30878	PC FOR ENERGY ONLY.TI TO (E) BLDG. RESTAURANT TO OTHER RESTAURANT. . less than 400A per applicant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45403	18041-20001-32674	9681 W HIGH RIDGE DR	90210	5	153B157   341	4384015034	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	34.11256	-118.42605	Expedite per applicant requestPlan check for PV roof mounted system with 10.4KW AC with 30 modules, 2 inverters(5.2KW), and 3 Battery  Back up Tesla PowerWall 2.0.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45404	19041-10000-25688	2500 S 8TH AVE	90018	10	123B189   500	5059016030	R1-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.03411	-118.32585	[e-plan] PLAN CHECK FOR 2 NEW ESS(TESLA POWER WALL) TO EXISTING PV SYSTEM AND 200A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45405	15041-10000-23944	3000 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.01674	-118.21552	"PC FOR POWER, SCOPE OF WORK IS TO ADD THREE NEW 800AMP SECTIONS TO THE SWITCHBOARD ""MSC"". TENANT 3080 AND 3090 ARE FUTURE TENANTS. 2500 AMP 480/277 VAC SERVICE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45406	12041-10000-17920	3550 W WILSHIRE BLVD #430	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	09/18/2012 12:00:00 AM	ADDRESS	34.06157	-118.30226	Change to lighting and loads to an existing office space.  Load for this project is less than 400Amps.  Other changes on other floors may increase the load to over 400Amps and full plan check may be required subject to field inspection.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45407	18041-10000-22528	1050 S GRAND AVE unit 3	90015	14	127-5A207 345	5139010***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.04171	-118.26155	FULL PC FOR A FIRST TIME TENANT, CHASE BANK, IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW PANELS, CIRCUITS AND LIGHTING. TOTAL SQ. FT. 3381. unit # 3building permit 18016-10000-13674	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45408	16041-20000-21199	10351 W DIAMOND ST LOT 6	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45409	16041-10000-34679	2029 S CENTURY PARK EAST 11th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Issued	02/14/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	checking for alteration of 31 fixtures replaced to LED type. less tahn 85% power density existing controls allowed. inspector verify existing shut off control in use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45410	17041-10004-17275	1156 S VICTORIA AVE	90019	10	129B189   419	5082025021	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM			PC Approved	06/26/2018 12:00:00 AM	ADDRESS	34.05137	-118.32603	SUPPLEMENTAL TO CHANGE TO APPROVED SET OF PLANS (DELTA 1) - CHANGES INCLUDE RELOCATION IF INVERTER, RELAY, LOAD CENTER, AND AC DISCONNECT TO BACK OF HOUSE, ALSO AN ADDITION OF A FUSE DISCONNECT TO BATTERY SYSTEM ORIGINAL PERMITInstallation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  1 new Tesla AC Powerwall 5.8 kVA 13.0 kWH battery and 1 new Solicia 7.6 kWac TL inverter (32 modules).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45411	17041-20000-00237	4415 S CENTRAL AVE	90011	9	112-5A209  93	5108028023	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.00344	-118.25677	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to dental office/tenant improvement. Total lighting area = 1,319 sq. ft.Note: Building permit has been pulled under 16016-10000-22826	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45412	13041-10000-12179	14006 W RIVERSIDE DR SUITE 24C	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			Corrections Issued	05/10/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	TI to an existing retail space in Sherman Oaks Fashion Square Mall (Suite 24C) for the opening of a new Starbucks store.  Title 24 plan check only.Permit to be issued at electrical plan check counter only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45413	15041-10000-33343	8225 N TOPANGA CANYON BLVD C-4	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.21902	-118.60624	TI TO EXISTING TMOBILE STORE. PLAN CHECK FOR ENERGY ONLY. TOTAL SQRFT 1937. SUITE C-4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45414	14041-20000-23661	20307 W VIA SANSOVINO	91326	12	219B113   269	2701061009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM			PC Approved	08/28/2014 12:00:00 AM	ADDRESS	34.29685	-118.57578	Modification to approved set under 14041-20000-16592.  Change from fully-rated system to series-rated system.  (((PV1.  Install 6.86 kW roof-mounted, utility-interactive PV system.  Transformerless inverter: SunnyBoy 6000TL-US-22)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45415	14041-10000-16350	601 S FIGUEROA ST 40th floor	90017	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLANCHECK FOR T24 ENERGY. ti to (e) office (4685 sqft) on 40th floor, emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45416	16041-20000-36297	104 N AVENUE 56	90042	1	151-5A227 232	5468024010	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.10918	-118.19452	Plan check power and energy. Tenant improvement for Figueroa Lodge. Newly connected load > 400amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45417	13041-10000-28351	11150 W SANTA MONICA BLVD 3RD FLR	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.04704	-118.44563	PERMIT TO BE PULLED AT THE ELECTRICAL PLAN CHECK COUNTER.TITLE-24 , PART 6 LIGHTING, PLAN CHECK ONLY FOR A COMMERCIAL HIGH-RISE BUILDING. USE OF SPACE ARE MAINLY FOR OFFICES. EMERGENCY LUMINAIRES WILL BE FED VIA EXISTING EMERGENCY CKT ( 2X ) FROM EXISTING GENERATOR. TOTAL WORK AREA TO BE 7579 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45418	19041-20000-29048	17949 W HATTON ST pv1	91335	12	186B129    17	2120013009	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.21026	-118.52437	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.(1) LG CHEM RESU 10H Battery	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45419	16041-10000-19102	1518 W 58TH PL	90047	8	108B193  1465	6002006033	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	33.98825	-118.30314	PV1 solar system installation to a single family home. Installing 10 microinverter modules rated 215 W. Total rating: 2.15kw.Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45420	15041-20000-36284	21800 W OXNARD ST Ste. 750 &-770	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.17898	-118.60253	TI for (E) high rise office build. New lights, all (E) circuits. PC for Energy only, total area: 2879 sq.ft.Scope at Warner Center Tower V, Ste. 750 and 770	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45421	12041-10000-06154	12053 W OSBORNE ST	91331	7	210B165   543	2532017066	(T)(Q)C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.06	Electrical	Electrical	Apartment			03/22/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	ADDRESS	34.27268	-118.39541	PLAN CHECK FOR  2 STORY 3 UNIT APARTMENT BUILDING. (BLDG #2). 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45422	11041-20000-13089	12020 W CHANDLER BLVD	91607	2	171B165   117	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	34.16825	-118.39512	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45423	16041-10000-19874	617 E 79TH ST	90001	9	099B205   612	6023032012	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Expired	07/11/2018 12:00:00 AM	ADDRESS	33.96759	-118.26432	PV2, INSTALL 2.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45424	14041-20000-36055	12734 N WOODLEY AVE	91344	12	222B137    17	2605003009	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2014 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.30284	-118.49828	PV1. Install roof mounted PV system sized 3.0 kW tied in with an existing pv system.  Interconnected with main service pannel.(16) kyocera KD 200- modules(1) abb 3.0 inverterreference master permit # 14041 20000 30172	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45425	18041-10000-09291	100 W WORLD WAY T162	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	PIN	33.94684048	-118.40128468	"PLAN CHECK FOR T24 ONLY, TI  TO RETAIL CONCESSION AT LAX; SPACE T162 OF 642 SQ FT  ON THE CONCOURSE LEVEL 3 OF TERMINAL 1. INSTALL (1) 225A PANEL AND ITS CIRCUITRY FROM (E) DIST. BOARD ""2LDSA"", TOTAL AREA: 642 SQ.FTB# 18016-10000-07682"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45426	11041-10000-00791	1091 S HOOVER ST	90006	1	130-5A201 224	5076007032	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.05116	-118.28438	INSTALLING NEW LIGHTING FOR PARKING LOT.  PLAN CHECK FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45427	11041-10000-02765	8905 N GLENOAKS BLVD BLDG B	91352	6	195B173   278	2408008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.23033	-118.36723	NEW  RETAIL  BUILDING SUBDIVIDED INTO 5 TENANT SPACES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45428	11041-10000-12792	5115 W MELROSE AVE	90038	13	141B193   539	5535015014	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			06/20/2011 12:00:00 AM			Verifications in Progress	07/07/2011 12:00:00 AM	ADDRESS	34.08364	-118.31165	NEW 600 A SERVICE UPGRADE FOR EXISTING 22 UNIT APARTMENT BUILDING WITH ALL NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45429	14041-10001-03872	4376 N FORMAN AVE	91602	4	165B181   204	2424024001	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.15018	-118.35257	Expedted RSES plan check per applicant request.{{PV1, Install 5.75 kW DC roof-mounted solar array for one-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 6000A-US. (23) Modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45430	13041-10001-33108	11021 N GLORIA AVE	91344	12	210B141   712	2667009017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.27057	-118.47931	Expedited RSES  plan check per applicant request.[][][]PV1, Install 6 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE6000A-US. (24)modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45431	18041-20000-44022	13790 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM			PC Approved	11/16/2018 12:00:00 AM	ADDRESS	34.30953	-118.43339	power plan check for seven existing units feeding from existing 1200 amps service board.TI under seperate permits.this is plan check only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45432	13041-10000-08684	11150 W SANTA MONICA BLVD	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	34.04704	-118.44563	TITLE 24 ENERGY PLAN CHECK FOR 6TH FLOOR. TOTAL AREA 10,775 SQ. FT. PART OF HIGHRISE. PERMIT TO BE ISSUED BY PLAN CHECK STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45433	17041-20000-09037	1515 S COLBY AVE	90025	11	129B149   589	4261001030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.04559	-118.4537	Fire alarm plan check only. New fire alarm system for (N) 4-story, 56-unit apartment building. (1) FACP and (252) Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45434	13041-10000-28088	6055 S VERMONT AVE	90044	9	105B197   610	6003021023	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	33.98472	-118.29168	TITLE 24 ENERGY PLAN CHECK ONLY .  RESTAURANT. NO CHANGE IN OCCUPANCY. 8938 SQFT.  EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45435	15041-10000-35528	310 W 95TH ST Classroom-Bld	90003	8	093A203    89	6053005015	R1-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	33.94992	-118.27899	Energy plan check for a new 2-story classroom building after a completed demolition.  Scope includes new lighting, equipment and receptacle. Total area is 10341-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45436	16041-10000-43906	777 S FIGUEROA ST #770	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only in existing high-rise building T.I. Total area: 3,446 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45437	12041-20000-03497	17522 W KITTRIDGE ST	91406	12	180B129   517	2229020017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	ADDRESS	34.19013	-118.51513	Photovoltaic system on roof a single family dwelling, using Enphase M215 inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45438	13041-10000-11962	1126 N HOOVER ST	90029	13	145-5A201 419	5429001011	R2-1XL	Central	Hollywood	Greater Griffith Park		1913.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	34.09172	-118.28441	Install roof mounted Microinverter P.V. system with 4.752 Kw.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45439	14041-20000-12081	10921 W WRIGHTWOOD LANE	91604	2	159B173   427	2380044030	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			Corrections Issued	06/04/2014 12:00:00 AM	ADDRESS	34.13176	-118.36791	Roof mounted PV system with, system size 8KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45440	13041-10000-33552	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Info Complete	02/13/2014 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR POWER ONLY. ADD 2 NEW CIRCULATING PUMPS AND OTHER MOTOR TO VFD. MOB data center - PUE upgrade. Located in raised floor server room.  VFD model?	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45441	16041-10000-22293	1150 W 36TH ST	90007	8	120B197   934	5040029011	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.023	-118.29322	PC FOR FA SYSTEM 5 DEVICES AND MAIN PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45442	15041-10000-03552	1188 S SAN PEDRO ST STE E	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	PIN	34.03375994	-118.25280059	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 364 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45443	14041-20000-10545	15303 W VENTURA BLVD SUITE 1550	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.15413	-118.46661	TI to reception area of high-rise office tenant space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45444	15041-20000-17147	555 W 5TH ST 1st Floor	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check for Title 24 only. Project site is the first floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area - 2,155 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45445	18041-10000-07709	8913 W 25TH ST	90034	10	126B169  1229	4302015022	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.03864	-118.3858	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING.  CONISIT OF 24 MODULES(Trina Solar 300W) AND A CENTRAL INVERTER (DELTA SOLIVIA 5.2) . SYSTEM SIZE IS 5.2KWac AND 7.2KWdc.SCOPE INCLUDES NEW LOAD CENTER (200A each).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45446	15041-20000-02609	10205 N LEMONA AVE	91345	7	204B149   288	2660018019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Expired	04/05/2017 12:00:00 AM	ADDRESS	34.2557	-118.45879	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.12 KW(34) SUNPOWER MODULES(1) POWER ONE 6KW(1) POWER ONE PVI 5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45447	13041-10000-16950	20903 W VENTURA BLVD	91367	3	171B109    76	2167001015	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	PIN	34.16677631	-118.58862304	PC AND PERMIT FOR TITLE 24 PART 6 ENERGY. less than 400A per applicant. TI existing - DRIVE THROUGH COFFEE SHOP <STARBUCKS>. has emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45448	18041-10000-22794	1261 S STONER AVE 1-8	90025	11	129B145   887	4263008009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			Reviewed by Supervisor	07/26/2018 12:00:00 AM	ADDRESS	34.04711	-118.46065	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON MULTI FAMILY RESIDENTIAL BUILDING- SYSTEM SIZE 7.36 kW AC/ 8.96 kW DC CONSISTING OF 32 IQ6 MICROINVERTERS AND (32) MODULESBATTERY BACKUP SYSTEM ON SUPPLEMENTAL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45449	11041-10000-23258	19350 W NORDHOFF WAY	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM			PC Approved	10/31/2011 12:00:00 AM	ADDRESS	34.23523	-118.55518	converting existing space into a laundry room at a 24-hr fitness clubplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45450	19041-10000-49143	1532 S BROCKTON AVE	90025	11	126B145   655	4263034036	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	11/18/2021 12:00:00 AM	ADDRESS	34.04056	-118.46035	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 NEW FIRE ALARM PANEL & 134 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45451	14041-10000-27925	850 N CAHUENGA BLVD	90038	13	144B185  1242	5533029001	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.08685	-118.32863	Title 24 plan check only.  Total area = 4,570 sq. ft.Addition of new air conditioning units and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45452	13041-10000-26323	17271 W AVENIDA DE LA HERRADURA	90272	11	141B117    44	4431013044	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.07889	-118.56267	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON STANDARD PLAN . 2 STRINGS, SYSTEM SIZE IS 4.25KW DC WITH (17) MODULES: TRINA #TSM-250PA05.18(1) POWER-ONE #AURORA PVI-3600	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45453	19041-10000-02506	10517 N WYSTONE AVE	91326	12	207B121   690	2728015024	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	PIN	34.26169724	-118.54851201	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.51KWdc / 5.04KWac.(21)MODULES- SO;FAB S;A 310 M (21)MICROINVERTERS-ENPHASE IQ7-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45454	14041-20000-35922	12822 W RANGOON ST	91331	6	198B161   332	2629027018	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.23786	-118.41235	Plan check for energy. TI and Showroom/storage. New receptacles and lighting including emergency.  28,262 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45455	11041-10001-20676	1046-1054 E ELKGROVE AVE BLDG 18	90291	11	111B145   391	4243001036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			05/30/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.002	-118.45901	LINCOLN PLACE APARTMENT PROJECT/  Addition of 3  1920 VA  EV.  16 AMPS AT 125%    20 AMPS CKTS. TO PREVIOUSLY APPROVED SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45456	16041-20000-08732	1950 S SAWTELLE BLVD Ste 310	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.04129	-118.44377	Remodel (E) tenant space.  New lighting , controls, receptacle outlets.  Plan check for energy - 2275 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45457	19041-10000-39408	3025 E WABASH AVE	90063	14	130-5A227 390	5229029019	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2032.00	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.04987	-118.19619	PC FOR ENERGY ONLY, SCOPE OF WORK IS CHANGE OF USE FROM STORAGE AREA TO COFFEE SHOP, TOTAL  CONNECTED LOAD IS UNDER 400A OF LOAD. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 676 SQFT. Note. Portion of permit fee is paid under 19041-10000-20626B#: 18016-10000-27982	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45458	17041-10000-25192	4551 S GLENCOE AVE STE 150	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.9844	-118.43407	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45459	18041-20000-40030	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.1937	-118.49152	installation of battery system 68.5KWh to an existing pv system on a commercial building. plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45460	17041-10000-08547	550 S HOPE ST #725	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Issued	03/24/2017 12:00:00 AM	ADDRESS	34.04989	-118.25574	Plan check for Title 24 only office space high-rise T.I. Total area: 2078 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45461	13041-20000-36085	151 S BARRINGTON PL	90049	11	135B145   542	4401006006	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM			Corrections Issued	12/27/2013 12:00:00 AM	ADDRESS	34.0656	-118.46913	change of use from jewelry store to juice bar	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45462	12041-10000-09601	7286 N HYANNIS DR	91307	3	186B093   622	2027015011	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	34.20284	-118.64006	New 9.68kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45463	18041-10000-08580	600 W 11TH ST Tower  1-52 stories	90015	14	127-5A207 344	5138015045	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Expired	02/02/2024 12:00:00 AM	ADDRESS	34.04296	-118.26462	PC for new FA system for Tower 1 ( 52-stories Apt/retail building ) of Oceanwide Plaza.This fire alarm system is part of a networking consisiting of FA systems for Tower 2, Tower 3, and Retail Podium	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45464	13041-10000-32434	654 E VERNON AVE	90291	11	111B145  1229	4239003018	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			Reviewed by Supervisor	05/01/2014 12:00:00 AM	ADDRESS	33.99767	-118.46818	PV1, Install 4.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 19 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45465	18041-20000-12459	4876 W FOUNTAIN AVE	90029	13	147B197  1157	5540012002	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.0953	-118.29579	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT - COFFEE SHOP  660 SF  NEW STOREFRONT; CHANGE OF USE FROM TAILOR SHOP TO COFFEE SHOPBUILDING PERMIT # 18016-10000-01510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45466	19041-20000-06630	4920 N VAN NUYS BLVD PV1-PV2	91403	4	169-5A151  47	2248007139	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.15995	-118.4485	PLAN CHECK FOR NEW PV SYSTEM ON EXISTING APARTMENT BUILDING. SYSTEM SIZE IS 101.47KW DC/100KW AC/92.24KW AC CEC. SCOPE OF WORK INCLUDES (278) ASTROHALO 365W PV MODULES WITH (139) P730 OPTIMIZERS, A SE100KUS INVERTER, AND A 150KVA TRANSFORMER.SECOND PV SYSTEM DONE ON SAME BUILDING UNDER PERMIT NUMBER 19041-20000-15670	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45467	17041-20000-43275	11633 W GORHAM AVE 1-10	90049	11	132B145   355	4401022028	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.05538	-118.46471	PV2. ROOMFOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45468	14041-10001-05963	231 W VERNON AVE	90037	9	112-5A203  33	5111010036	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.00394	-118.27727	PLANCHECK FOR POWER. UPGRADING OF SERVIVICE FROM 1000AMPS @ 208V TO 800 @ AT 480V FOR A MEDICAL DIAGNOSTIC CENTER. BRODWAY RADIOLOGY.((((((((    MOVING THE XFMR WITHIN 25 FT. IN ORDER TO PROVIDE CLEARANCE IN FRONT OF THE GEAR.))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45469	17041-20002-20218	11136 W MAGNOLIA BLVD	91601	2	171B173   628	2353005013	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.16478	-118.37367	Revisions to approved plans.  (E) service voltage class changed to 240/120V 3ph-4w delta.  Additional subpanel, recircuiting of loads, lighting revisions. (((Change of use from theater to restaurant.  newly connected load >400 amps.  plan check for power and energy.    Building application number #17016-30000-15466.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45470	13041-20000-21838	9727 W OAK PASS ROAD PV-1	90210	5	153B157    99	4384007035	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	34.11784	-118.42776	PV-1. Plan check for PV. 8kW with combiner box.  Plan check/permit is for PV system only, NOT for De-rating any main breakers or for any service panel upgrades.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45471	15041-20001-37580	6400 N LAUREL CANYON BLVD Suite 600	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	ADDRESS	34.18693	-118.3963	Revisions to approved set.  Lighting design changes, slight modifications to architectural layout.  (((Plan check for Title 24 only. Project site a suite within an existing commercial high-rise building (6th floor, Suite 600). Project scope is a tenant improvement. Total lighting area = 6,606 sq. ft.Note:  Building application has been filed under 15016-20000-20273)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45472	15041-20000-27415	633 W 5TH ST #1750	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check Title 24 only for existing office space  highrise. Total indoor area: 6,125 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45473	14041-20000-34547	3513 W SUNSET BLVD	90026	13	144A203   174	5429024002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.08921	-118.27641	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHTING TO EXISTING PANELS, ADDING NEW BRANCH CIRCUITS.  TOTAL SQUARE FOOTAGE PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45474	17041-30000-09043	350 S FIGUEROA ST 38th Floor	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Issued	05/05/2017 12:00:00 AM	ADDRESS	34.05438	-118.2549	Plan check for Title 24 only. Project site is the 38th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45475	19041-20000-46509	17500 W BURMA ST	91316	5	174B129   134	2254023021	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.17676	-118.51418	PV1. INSTALL 3.04 KW DC PV SYSTEM WITH (8) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45476	13041-20000-25639	15435 W VANOWEN ST	91406	6	183B145   732	2234025016	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Apartment			09/19/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.19405	-118.46976	NEW 3-STORY 29 UNIT APARTMENT BUILDING WITH 12OO A SERVICE. FIRE ALARM VARIANCE HAS BEEN FILED. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45477	16041-10000-45109	510 W 7TH ST	90014	14	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.04671	-118.25598	Plan check for Title 24 only in existing space T.I. change of use from retail to restaurant. Total area: 1,390 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45478	11041-10000-14280	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.0365	-118.3687	TI, LIGHTING CHANGES FOR AN EXISTING WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45479	16041-10000-12519	3812 W OAKWOOD AVE	90004	13	138B197    84	5501001023	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.07761	-118.28979	PV1, INSTALL 9.75 KW AC, 10.725 KW DC  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(39) MODULES:SOLARWORLD SW 275 MONO BLK(39) MICROINVERTER: ENPHASE ENERGY M250-60-2LL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45480	17041-20001-30293	18765 W FAIRFIELD ROAD	91326	12	207B121   627	2728029044	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.26205	-118.54171	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.76KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45481	16041-10000-19142	7828 N LEDGE AVE	91352	2	189B177   574	2405002022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.21288	-118.35739	PV1 SFD TOTAL SYSTEM SIZE 3.8KW AC USING CENTRAL INVERTER WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45482	12041-20000-18945	22434 W ITASCA ST	91311	12	201B101   529	2727001009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.24427	-118.61603	Plan check for PV system. M215 Micro inverters. 12.25KW system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45483	15041-10000-18575	614 E TERMINAL WAY power shop	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.74201	-118.26431	New fire warning system for Power Shop Building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45484	12041-10000-06989	8380 W MELROSE AVE Unit #102	90048	5	141B173   499	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.08343	-118.37293	REMODELING OF EXISTING RETAIL STORE Unit #102. PLAN CHK IS FOR TITLE  24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45485	15041-10001-32877	1640 W SEPULVEDA BLVD STE 103-104	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM			PC Approved	11/25/2015 12:00:00 AM	ADDRESS	33.8166	-118.30825	CHANGES TO APPROVED SET OF PLANS. CHANGE INCLDE USE OF STRIP LIGHITNG INSTEAD OF DOWN LIGHTS. NO ORIGINAL SET PRESENT. PC FOR ENTIRE T24 AGAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45486	17041-10000-05132	8500 W BEVERLY BLVD SUITE #115	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	Full plan check TI for a restaurant in shell space(mall). New distribution board rated at 800 Amps, feeding new panels. New lighting and power. Area: 8902.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45487	17041-10001-09376	1314-1342 W ADAMS BLVD	90007	8	123B197   898	5055006012	R4-1L-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Closed	09/22/2020 12:00:00 AM	ADDRESS	34.0325	-118.2894	PC FOR CHANGES TO APPROVED SET OF PLANS AND PERMIT FOR CHANGE OF ADDRESS. FA SYSTEM IS 3 SYSTEMS CONNECTED TO SINGLE COMMON STATION. PERMITS FOR ALL SYSTEMS SEPARATED BASED ON BUILDING ADDRESS. PERMITS 17041-10000-10526 AND PERMITS 17041-10000-11110 STILL ACTIVE FOR THOSE DEVICES. THIS APPLICATION AND PERMIT SHALL COVER ENTIRE SITE AS WHOLE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45488	10041-10000-14620	8500 W BEVERLY BLVD # 679	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	09/20/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVENET IN THE SUPERDRY STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45489	15041-10000-21815	700 W 7TH ST Suite S300	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM			Corrections Issued	07/09/2015 12:00:00 AM	ADDRESS	34.04797	-118.25815	Energy plan check for a retail store, suite #S300, located in a commercial building. Main scope includes new lighting and receptacles. Total area is 1076-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45490	19041-10000-52263	755 S LOS ANGELES ST	90014	14	127-5A211 230	5145001013	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			Verifications in Progress	01/22/2020 12:00:00 AM	ADDRESS	34.04231	-118.25201	PC for a TI of a food hall in an existing building . Existing service size 3000A,480/277V,3PH,4W. Area of scope (11,216)SF.************************************************************************************HIGHRISE TENANT IMPROVEMENT AT BASEMENT, FIRST FLOOR AND MEZZANINE LEVEL TO AN (E) 5-STORY MIXED USE NON-DUCTILE CONCRETE BUILDING TO INCLUDE: TENANT PREP AREAS AND DISHWASHING AT BASEMENT LEVEL, (17) TENANT SPACES AND (1) COMMON KITCHEN AT FIRST FLOOR LEVEL, SEATING AT MEZZANINE LEVEL.************************************************************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45491	18041-10002-24210	1728 W 84TH ST	90047	8	097-5A193  56	6034024010	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	33.9626	-118.30786	"PC FOR DC COUPLED ESS IN A SFD. PART OF A PV PROJECT UNDER MASTER APPLICATION. SCOPE INCLUDES ""LG"" DC COUPLED ESS, AUTO TRANSFORMER AND PANEL."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45492	16041-10000-37821	10812 W MAGNOLIA BLVD	91601	2	171B177   698	2419008017	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM			PC Info Complete	07/06/2018 12:00:00 AM	ADDRESS	34.16466	-118.3663	FULL PC FOR POWER AND ENERGY FOR A NEW 31 UNIT MIXED USE 4 STORY BUILDING. SCOPE INCLUDES A NEW 1200A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW SUBPANELS, AND CIRCUITS. FOUR DIFFERENT TYPES OF PANELS ARE USED FOR THE DWELLING UNITS. TOTAL AFFECTED AREA IS 44468 SQ. FT. B#16010-10000-00653 fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45493	16041-10001-39052	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	PC FOR CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO RTU FEEDER LOAD AND SIZE. UPDATED LIGHTING PLAN TO PROVIDE NOTE DAYLIGHT ZONES. PC ONLY. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45494	10041-20000-19822	2508 S FIGUEROA ST #F	90007	9	121-5A203  24	5124027017	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	10/29/2010 12:00:00 AM	ADDRESS	34.02881	-118.27527	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR OFFICE TI. SUITE F	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45495	14041-10000-02073	1536 S SELBY AVE	90024	5	132B153   860	4325029008	[Q]RD1.5-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.05478	-118.4372	PLANCHECK FOR FIRE ALARM SYSTEM. 2 STORY BUILDING. FULLY SPRINKLERED. 1 FACP, 2 RPS AND  111 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45496	18041-30000-42484	625 N BUNKER HILL AVE	90012	1	135A213   405	5407004042	R4-1	Central	Central City North	Historic Cultural	YES	2071.01	Electrical	Electrical	Apartment			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.06202	-118.24445	Replace Fire Alarm control panel and install new devices. (1) FACP, (81) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45497	10041-10000-11864	330 S CENTRE ST	90731	15	018B201   821	7455019919	C2-2-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	33.74055	-118.28332	New Fire alarm system. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45498	13041-10001-31499	13897 N ELDRIDGE AVE	91342	7, 8	228B157  1119	2503003005	(T)RE11-1-K, R2-1	North Valley, South Los Angeles	South Los Angeles, Sylmar	Empowerment Congress North Area, Sylmar		1060.10, 2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.32445	-118.43353	Expedited RSES plan chek per applicant request. (((PV1, Install 2 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US. 8 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45499	11041-10000-08711	6415 W ROMAINE ST	90038	13	144B185   949	5533014011	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM			PC Info Complete	05/06/2011 12:00:00 AM	ADDRESS	34.08902	-118.33049	SUPPLEMENTAL PERMIT TO 10016-10000-20265 TO REVISE AGE OF CHILDREN IN CHILD CARE FACILITY FROM 18-60 MONTHS TO 30-60 MONTHS. OCCUPANCY GROUP CHANGES FROM I4 TO E. FIRE SPRINKLERS NOT REQUIRED. NO OTHER CHANGES TO APPROVED PLANS.((((((((((((( TITLE 24 ENERGY AND EMERGENCY LIGHTHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45500	10041-10000-06884	241 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			04/15/2010 12:00:00 AM			Reviewed by Supervisor	05/13/2010 12:00:00 AM	ADDRESS	34.04997	-118.22706	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45501	13041-20000-00405	7125 N SCARBOROUGH PEAK DR	91307	3	183B089   152	2028010019	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2013 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.19999	-118.65362	New 10.15kw PV rooftop system for an existing single family residence.  System is ungrounded and uses SolarEdge DC-DC Converters.  PLAN CHECK IS FOR PV SYSTEM ONLY, PERMIT FEES ARE UNDER INSPECTION INCLUDING SERVICE UPGRADE. PERMIT FEE FOR 200A service upgrade has been included!!!	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45502	14041-20000-16016	19812 W SATICOY ST	91306	3	186B113   210	2115016009	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.2082	-118.56486	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 4.3 KW AC USING MICROINVERTERS. NONSTANDARD PLAN. 20 MODULES TOTAL. USING THE ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45503	11041-10000-24378	948 E LAKE ST BLDG 4-2	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/28/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.001	-118.46101	Lincoln Place Apartment Building Project.  New 2-story apt. building with 7 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45504	19041-10001-18523	16556 W PARK LANE CIR	90049	11	159B137   588	4490008003	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	ADDRESS	34.12806	-118.49283	EXPEDITE FEES FOR:NEW ROOF MOUNTED 13.73 KW PV SYSTEM WITH 45 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45505	12041-10003-15061	1600 N WESTERN AVE	90027	13	148-5A193 302	5544022035	[Q]R5-2	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.10004	-118.30899	[[[6/17/14]]]] CHANGES TO APPROVED SET OF PLANS. ADDITION OF TWO Q TYPE CHANDELIERS AND THREE J2 TYPE DOWNLIGHTS. DELTA 2 CHANGES ONLY.Plan check power and energy for new 4-story 40 unit apartment with 1600A service. Modification to separate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45506	15041-20000-43763	10722 N CEDROS AVE	91345	7	207B149   360	2648020020	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Refund in Progress	01/24/2017 12:00:00 AM	ADDRESS	34.26507	-118.45303	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (31) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45507	19041-10000-02552	13171 N TELFAIR AVE B	91342	7	225B141  1501	2604002052	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Closed	10/21/2019 12:00:00 AM	ADDRESS	34.31032	-118.47927	"PER APPLICANT REQUEST: FULL PLAN CHECK FOR A CHANGE OF USE FROM ""OFFICE"" TO ""OFFICE/LABORATORY. SCOPE INCLUDES NEW EQUIPMENT SUCH AS (1) 112.5kva TRANSFORMER, (1) 400A PANEL, (7) 100A AND (1) 125A SUBPANELS, AND NEW BRANCH CIRCUITS ALONG WITH EGRESS LIGHTING.T24 LIGHTING TO BE DONE UNDER SEPERATE PERMIT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45508	11041-10000-25046	9410 N OWENSMOUTH AVE	91311	12	198B105    85	2746014043	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.24138	-118.60168	Plan check new 100.8KW roof mounted Photovoltaic System. Modules located on roof  of warehouse building (9410 Owensmouth Ave.) connecting to Inverter located in main office building (9340 Owensmouth Ave.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45509	10041-10000-09981	4448-4452 E HUNTINGTON DR SOU 4450&4448	90032	14	142-5A229 488	5214008005	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM			PC Approved	05/26/2010 12:00:00 AM	PIN	34.08267037	-118.1890038	Ti in an existing retail space (#4450 & 4448) . Plan check for T24 and energy. (Permite is already issed #10041-20000-02092)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45510	19041-10001-42370	20953 W OSBORNE ST	91304	3	195B109    47	2779001030	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.23315	-118.59033	EXPEDITE FEESPV2, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 26.4 KWdc/22.8KWac. SCOPE OF WORK INCLUDES 110 MODULES (ORION ECO240S15P-60) WITH OPTIMZERS (SE P320) AND THREE CENTRAL INVERTERS (SE7600H-US) LEADING TO A 200A LOAD CENTER. INTERCONNECTED TO A 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45511	17041-10000-38287	2229 S CARMELINA AVE	90064	11	123B149   849	4259026015	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.02998	-118.45547	ALTERATIONS IN EXISTING OFFICE SPACEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45512	10041-10000-11565	17100 W SUPERIOR ST	91325	12	201B133   456	2692002017	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM			PC Info Complete	09/03/2010 12:00:00 AM	ADDRESS	34.24654	-118.50474	AT THE HIGHLAND HALL WALDORF SCHOOL, NEW CONSTRUCTION OF TWO-STORY CONSTRUCTION BLACK BOX THEATER WITH CONTROL ROOM AT THE UPPER LEVEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45513	11041-10000-04561	8809 W PICO BLVD	90035	5	132B169   845	4332014018	C4-1VL-O	Central	Wilshire	South Robertson	YES	2170.01	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Approved	11/17/2011 12:00:00 AM	ADDRESS	34.055	-118.38402	TI TO AN EXISTING RESTAURANT IN THE KITCHEN ONLY.  T-24 OVER THE COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45514	18041-20000-09779	9833 W KINCARDINE AVE	90034	5	123B165   221	4311001003	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.03574	-118.39923	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.32 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45515	19041-20000-15489	11510 S WILMINGTON AVE	90059	15	084B213    97	6067001021	CR-1VL	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	33.92996	-118.23891	200A 240/120V 1ph-3w service, power, and lighting for parking lot. Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45516	19041-20000-16545	1130 N MEYLER ST	90731	15	021B197   327	7445012029	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	33.75441	-118.29656	Plan check for PV roof mounted with battery back up system, PV system size: 6.07KW DC, 7.6KW AC with 21 PV Modules and 1 inverter(7.6KW)  and 1 LG Chem Battery Energy storage system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45517	18041-20000-28024	5054 E ALHAMBRA AVE	90032	14	138A233   355	5216024010	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Issued	02/12/2019 12:00:00 AM	ADDRESS	34.07052	-118.17584	ti to an exsting commercial.  adding new lighting new controls to new panels.  newly connected load < 400 amps. Plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45518	13041-10000-30833	21250 W MULHOLLAND DR	91364	3	162B105    79	2173018005	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.14313	-118.59627	PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. STANDARD PLAN. 2 STORY. SYSTEM SIZE: 11 KW.(44) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS IG PLUS V 10.0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45519	16041-20000-19188	19450 W SHERMAN WAY	91335	3	183B117    87	2130026003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.20088	-118.55725	Plan check for an addition of a PV1 roof-mounted PV system. Addition system size is 3 kWac for a total system size is 6 kWac. Addition consists of (1) inverter, (1) load center, and (14) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45520	19041-20000-18525	4208 N ALLOTT AVE	91423	4	165B157   924	2373009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			Verifications in Progress	06/06/2019 12:00:00 AM	ADDRESS	34.14616	-118.4281	addition of (1) tesla powerwall ESS rated at 5KW for an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45521	15041-20001-26314	6633 W HOLLYWOOD BLVD	90028	13	148-5A185 113	5547004006	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.10174	-118.33447	Changes to approved set.  Changes to lighting and receptacle layout.  Plan check for Title 24 only. Project site is an existing commercial building (restaurant). Project scope is a tenant improvement. Total lighting area = 6,207 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45522	13041-10000-08376	1375 E 6TH ST	90013	14	126A217   125	5164008011	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.03838	-118.23372	NEW LIGHTING LAYOUT FOR SUPPORT SPACES OF NEW FITNESS CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45523	13041-10001-10580	380 W WORLD WAY T52	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Delta 2 revisions- track lighting have been revised; emergency luminaures have changed; photometric plan for egress lighting revisedPLAN CHECK ONLY(((((((per applicant's request, application taken in as a full plan check for power (T24 has already been done). power fees to be added under submittal 2. for concession space #T52-R (Fred Segal)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45524	12041-10000-01901	500 W WORLD WAY 5N	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. to an existing retail space.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45525	12041-20000-03384	1355 S HILL ST	90015	14	124-5A207  89	5134025020	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Info Complete	05/22/2012 12:00:00 AM	ADDRESS	34.03646	-118.26342	New electrical system for remodeled building where the number of units was reduced from 51 to 41, to renovate restrooms/finishes & to relocate stairs.  Add (N)elevator within bldg. and ramps to provide H/C access and to add stair.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45526	16041-10000-01836	3494 E PICO BLVD	90023	14	118-5A225 320	5190036804	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM			PC Approved	01/19/2016 12:00:00 AM	ADDRESS	34.0179	-118.20314	T-24, INSTALLING NEW LIGHTING TO THE GENERATOR YARD. PC FOR OUTDOOR T-24. TOTAL SQ. FT. 750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45527	10041-20000-00207	7509 W SUNSET BLVD	90046	4	147B177   984	5550010021	C4-1D	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM	02/12/2010 12:00:00 AM		Permit Finaled	06/07/2010 12:00:00 AM	ADDRESS	34.0982	-118.35316	Tenant improvement - remodel of (E) coffee shop. Title 24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45528	16041-20000-14580	5338 N CARTWRIGHT AVE	91601	2	171B177   202	2416027060	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.16776	-118.36304	Fire alarm plan check only. Install a new fire alarm system for a 21-unit, 3-story apartment building. FACP + 89 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45529	19041-10000-47708	960 W 7TH ST	90017	14	129A207    16	5144009079	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	03/13/2020 12:00:00 AM		Permit Finaled	06/27/2023 12:00:00 AM	PIN	34.04918918	-118.26209882	NEW FIRE ALARM SYSTEM IN A HIGH RISE BULDING. SYSTEM CONSIST OF 1 FA PANEL, COMMUNICATOR, ANNUNCIATOR, 31 POWER SUPPLIES  AND 3,610 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45530	14041-10000-24763	380 WORLD WAY T 03	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 plan check only.  Total area = 773 sq. ft.TI to airport terminal kiosk.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45531	15041-20000-43670	4860 W SANTA MONICA BLVD	90029	13	144B197   760	5538019001	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.09071	-118.29546	Plan check for Core and Shell for fire damage building; Service 800A with (9) 100A Sub panels. Total area: 5600 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45532	16041-10000-11586	1724 W 254TH ST	90717	15	036B193   928	7410013059	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	33.79339	-118.30869	PV1, INSTALL A NEW 3.0KWac ROOF-MOUNTED SOLAR ARRAY TO AN EXISTING 5.0 KWac SOLAR SYSTEM ON A SINGLE FAMILY HOME. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS 8.0KWac.  (15) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45533	14041-10000-14288	920 N VIGNES ST	90012	14	132A217    28	5409017900	PF-1XL	Central	Central City North			2060.20	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM			Reviewed by Supervisor	07/02/2014 12:00:00 AM	ADDRESS	34.05723	-118.23154	NEW FIRE ALARM SYSTEM FOR A NEW OFFICE BUILDING. 464 DEVICES AND 11 PANELS PER APPLICANT ESTIMATE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45534	16041-20000-16440	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check for Power and energy in existing building T.I. Netflex. Install new (2) 25kW UPS Systems, (4) 200KVA Transformers with associated panels and circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45535	16041-10000-09826	12673 W SUNRISE PL	90094	11	102B161  1275	4211037031	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.97669	-118.41407	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH AN AC PV SUPERVISOR. TOTAL SYSTEM SIZE IS 2.08KWac.(8)AC MODULES-SPR-X20-250-BLK-B-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45536	13041-10000-19525	2966 N TIFFANY CIR	90077	5	156B149    12	4379034025	RE15-1-H-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.1278	-118.44587	PV1 8.415KW 240V XFMR INV. 2STORY. STD. ROOFMOUNT.[( 1) INV: sunnyboy SB8000US][( 33) MOD: Alea S18U255]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45537	11041-20001-26413	17947 W CHATSWORTH ST Bldg. L	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM			PC Approved	03/12/2012 12:00:00 AM	ADDRESS	34.265	-118.52509	Changes from previously approved plans.  Changes include reducing of the tenant units, lightings, and panels.  Plan check for power and energy.  Note: the approved plans submitted for reference only.Permit was previously issued under PCIS 11041-20000-26413.(****Provide 1600 A new service with 5 service disconnecting means, for a remodel of an existing commercial building.  The remodel is for exterior building lighting, and interior spaces L1 and L4.  Spaces L2 and L3 will be part of future work to be done by the tenants.****)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45538	16041-10002-16755	8250 N WOODMAN AVE	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.22107	-118.43251	PC for changes to approved set.  Partial changes to module type from HIS-S325 to HIS-M310 modules and changes in panel roof layout.  System sized changed to 384.3(ac) and 302kW(dc).  Approval only for clouded changes marked as delta-4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45539	14041-20000-21784	10932 N WESCOTT AVE	91040	7	207B189    84	2551044007	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.2676	-118.31733	PV1.  Install 7.8 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45540	19041-10001-25800	1320 N LAKE SHORE AVE	90026	13	141A209   702	5419031013	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1974.20	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM			PC Approved	08/02/2019 12:00:00 AM	ADDRESS	34.07876	-118.2599	Changes to approved set, changes include changing fixture type on floor plan and changes to T24. Permits will be pulled under 19041-10000-25800. Orginal Scope of work: CHANGE OF USE FROM OFFICE TO GYM. T-24 Enery Only. Total Area: 5559 Sqr Ft. Building Permit: 19016-10000-17913	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45541	16041-20000-41871	700 S FLOWER ST suite 585	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only total square footage 2375.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45542	15041-20001-03018	12481 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9791	-118.41047	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45543	13041-10000-26138	1520 E 15TH ST	90021	14	120A213    63	5130016024	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.0245	-118.24348	Alteration repair of fire-damaged single story retail building.  Title 24 plan check only for lighting: newly connected load less than 400A.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45544	13041-10000-05448	763 E 15TH ST	90021	14	123A211   349	5132026024	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	34.02972	-118.25347	RENOVATION OF EXISTING RETAIL SPACE. PC FOR T24 ENERGY ONLY. PERMIT ALREADY ISSUED BY EXPRESS. T24 PLAN CHECK FOR LIGHTING IN OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45545	10041-20000-16684	4558 N SHERMAN OAKS AVE	91403	5	168B145   971	2283023003	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1413.02, 1414.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	08/26/2010 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.15356	-118.46889	lighting and power and relocating and adding panel boards. P/C is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45546	14041-20000-17398	5268 N TUJUNGA AVE	91601	2	171B173   338	2350017008	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.16676	-118.37882	Plan check for power energy on new built hotel, 4 stories, with 43 guestrooms  and 1 dwelling unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45547	15041-10000-02195	707 W WILSHIRE BLVD Ste 458	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	Power plan check.  New optional standby distribution and UPS for fourth floor tenant suite in an (E) commercial highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45548	12041-10000-16899	5319 W VENICE BLVD	90019	10	126B177   187	5069034001	C2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	08/28/2012 12:00:00 AM	ADDRESS	34.04469	-118.3558	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. CHILD DAY CARE CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45549	17041-20001-46683	7509 N MADORA AVE	91306	3	186B113   377	2115012019	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.20634	-118.56629	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.5.98kW ungrounded system.(26) EnPhase IQ6-60 microinverters.(26) 305W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45550	18041-10000-20342	6505 S ESPLANADE #4	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	33.96159	-118.45071	PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW LOAD CENTER, 6 MODULES(#SC325) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 1.95KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45551	14041-20000-34260	16457 W KINGSBURY ST	91344	12	207B137   488	2679014020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.26391	-118.49105	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). Ungrounded system.36  255W pv modules across 4 strings (inv1: 9+9; inv2: 10+8).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45552	15041-10000-18917	1119 1/2 S HOPE ST	90015	14	127-5A207 269	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.04186	-118.26375	FULL PC, CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE IN AN (E) BUILDING. PC FOR ENERGY AND POWER.  TOTAL SQ. FT. 944.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45553	15041-10000-43214	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	PIN	33.92817449	-118.43220714	REPLACE AND UPGRADE 2 SECTIONS OF 34.5KV GENERATION UNITS. INSTALLING 3 MAIN GENERATION UNITS WITH 4 MCC AND RELATED EQUIPMENT FOR CONTROL AND OPERATION OF GENERATORS. HAZARDOUS LOCATIONS MARKED ON PLANS. INSTALL 13.8KV AND 4160V DISTRIBUTION EQUIPMENT. NEW LIGHTING IN GENERATION ROOMS. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45554	13041-10000-23704	10472 W TROON AVE	90064	5	126B161   519	4318018027	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.03854	-118.41318	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 7 KW AC. 33 MODULES AND 1 INVERTER. [INVERTER: SMA # SB7000-US |||| MODULES: MONOX BLACK # LG250S1K-G3]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45555	19041-10000-18550	8472 N CORBIN AVE	91324	12	192B117   317	2783011014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	ADDRESS	34.22426	-118.56207	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45556	10041-10000-05231	2930 E WHITTIER BLVD	90023	14	123A223   248	5189004040	C1-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2047.00	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Expired	12/09/2015 12:00:00 AM	ADDRESS	34.03069	-118.20803	Plan check power and energy for new service upgrade from 400A to 800A. New switchboards, panels, equipments, and ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45557	15041-10000-18346	14960 W OSWALD ST	91342	7	222B149   998	2506007011	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.30192	-118.45852	PV1 INSTALL 4.578 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(14) MODULES: SUNPOWER SPR327NE(1)INVERTER: POWER ONE PVI -4.2-OUTD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45558	18041-10000-34948	10211-10215 N TUJUNGA CANYON BLVD	91042	7	204B197  1137	2568009021	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.25165	-118.29114	INSTALLATION OF FIRE PANEL FOR SPRINKLER MONITORING SYSTEM. PC FOR HORN AND SMOKE DETECTOR INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45559	19041-10000-32771	624 S GRAND AVE	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM	05/07/2020 12:00:00 AM		Permit Finaled	01/18/2021 12:00:00 AM	ADDRESS	34.04802	-118.25572	REPLACING A DAMAGED 3/4 MVA MEDIUM VOLTAGE TRANSFORMER WITH A NEW 3PHASE, 3/4 MVA, 4,160V:277/480V 4W TRASFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45560	13041-20000-17748	5450 W PICO BLVD #204	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.04862	-118.35714	T24 FOR EXISTING RESTAURANT. TOTAL SQRFT 847	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45561	15041-10000-07761	4801 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.04683	-118.34063	METHENE MITIGATION SYSTEM (LEVEL 5). 9 CONTROL PANEL AND 15 SENSOR. PER FRANCIS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45562	19041-20003-29753	6363 W WILSHIRE BLVD ste 516	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.06385	-118.3674	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE FROM INVERTER TO BATTERY BACK UP FOR EGRESS LIGHTING, REMOVAL OF PHOTOSENSORS, CHANGE TO LIGHT CONTROLS ON T24 SHEET, CHANGES MADE TO SPECIFIC NOTES, AND CHANGE TO SINGLE LINE DIAGRAM REMOVAL OF LOADS FROM PANEL SCHEDULE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45563	19041-20000-08136	1839 S MESA ST LOT 21	90731	15	012B201   796	7456029047		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	33.72713	-118.28613	PLAN CHECK FOR NEW SOLAR ROOFMOUNT PV SYSTEM 3.015KW DC/2.88KW AC, SCOPE OF WORK INCLUDES (9) SUNPOWER SPR-X21-335-BLK-D-ACPV PANELS WITH INTEGRATED MICROINVERTERS, ON A NEW SFD TOWNHOUSE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45564	17041-10000-34828	5229 N MT ROYAL DR	90041	14	163-5A225 179	5669019023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	11/04/2017 12:00:00 AM	ADDRESS	34.14226	-118.20377	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 6.54KWDC/ 6.0KWACSCOPE INCLUDES SIGNLE INVERTER SE6000A20 MODULES SPR-327NEW/ OPTIMIZERS SE-P400	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45565	16041-10000-10406	7021 N NESTLE AVE	91335	3	183B125   514	2125032018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Expired	04/25/2018 12:00:00 AM	ADDRESS	34.19819	-118.53071	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.6KWac.(16)MODULES-HYUNDAI HIS-M255-RG(1)INVERTER-ABB PVI-3.6 OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45566	15041-10000-35169	16633 W VENTURA BLVD #1400	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	PC FOR ENERGY. TI FOR OFFICE LOCATED IN THE 14TH FLOOR OF A  HIGH RISE BUILDING. TOTAL AREA 6540 SQ FT. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45567	13041-10000-30862	10724 W HOLMAN AVE	90024	5	132B153  1064	4325030005	[Q]RD1.5-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Apartment			11/05/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.05472	-118.43414	NEW FIRE ALARM SYSTEM TO AN EXISTING APARTMENT BUILDING FOR CHURCH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45568	13041-10000-24566	8248 N SEPULVEDA PL 1-17	91402	6	192B145   447	2209001007	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	Apartment			09/09/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.2211	-118.46605	INSTALLATION OF A NEW FIRE ALARM SYSTEM IN A 4-STORY APARTMENT BUILDING. FULLY-SPRINKLED SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45569	13041-10000-16770	6211 W FRANKLIN AVE	90068	4	150A189   170	5586006028	C1-1D	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	PIN	34.10543625	-118.32483465	PERMIT IS FOR LIGHTING UNITS IN EXISTING BRANCH CIRCUITS A ND A REPLACEMENT PANELBOARD IN THE SAME EXACT LOCATION.*****************************************************************************TENANT IMPROVEMENT. PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING FOR A DONUT STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45570	18041-20000-46885	13270 W SEVILLANA WAY	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) micro-inverters and (7) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45571	19041-20000-36301	3630 W WATT WAY 3RD & 4TH-FLR	90089	9	118-5A201  14	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.02062	-118.28738	TENANT IMPROVEMENT ON 3RD AND 4TH FLOORS IN (E) OFFICE BUILDING P.C FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45572	18041-10000-32120	120 E 25TH ST	90011	9	121-5A205 306	5127037022	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.02518	-118.26724	Install a new Fire Alarm system in the building with 67 Devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45573	19041-10000-24791	7311 W SUNSET BLVD	90046	4	147B181   598	5550017021	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Issued	06/27/2019 12:00:00 AM	ADDRESS	34.09817	-118.34929	Plan check for removing HID fixtures and replace with new LED Fixture for outdoor area with a total lighting fixture of 7500-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45574	13041-20000-11772	806 N ILIFF ST	90272	11	126B129   225	4423025002	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.04379	-118.51813	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 5 KW. USING TRANSOFRMERLESS INVERTER NONSTANDARD PLAN. CONDUIT PENETRATING ROOFTIP. 400 A PANEL. USING TOTAL OF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45575	16041-20000-04594	13932 W OTSEGO ST	91423	4	171B153   681	2269011006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.16259	-118.43686	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (18) modules, (18) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45576	19041-10000-14651	429 N VISTA ST	90036	5	141B181  1394	5526032008	RD1.5-1-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.07904	-118.35234	PV1. Plan check for a 11.056 KW AC / 12.2KW DC roofmounted system with (1) inverter, (40) modules, and optimizers interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45577	14041-20000-18776	11078 W SANTA MONICA BLVD	90025	5	129B153   843	4323020025	C2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.04753	-118.44371	Plan check for energy only. Remodel of existing restaurant (Berri Pizza), new lighting (incl. emergency). 1,342sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45578	18041-10004-02493	1353 W 60TH PL	90044	9	105B197   439	6003017023	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	33.98513	-118.2998	"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA ""C.1"". CHANGES INCLUDE INTERCONNECTING PV BATTERY BACK UP TO THE MAIN SERVICE. REPLACING 100A PANELBOARD WITH AN ATS PANELBOARD AND INSTALLING A 25A ATS BREAKER."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45579	18041-20000-33335	21601 W VICTORY BLVD	91303	3	180B105    75	2139001009	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.18827	-118.59992	Plan check for Title 24 Energy only in existing space luminaire alteration replace one for one lighting fixture LED tetrofit in existing panels and wiring being utilized. No panels or branch circuits are being  moved, replace or installed. Total area: 46,114 sq f.t	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45580	13041-20003-30088	23424 W CALIFA ST	91367	3	174B093    29	2041004004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Expired	04/20/2016 12:00:00 AM	ADDRESS	34.17721	-118.63725	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE INCLUDE FAULT CURRENT CORRECTION. CONTRACTOR TO PROVIDE 22K BRACING SUBPANEL.(($0 PLAN CHECK AND PERMIT DUE TO SENATE BILL 12222 FROM 2012)))))PER INSPECTOR REQUEST. INSTALL FUSE LET THRU. FUSE LET THRU TO BE A MODIFICATION UNDER INSPECTOR FURGESON.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45581	18041-10003-23846	4238 S 7TH AVE	90008	10	114B189  1370	5023017038	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Expired	10/18/2023 12:00:00 AM	ADDRESS	34.00602	-118.32467	FEES FOR BATTERY STORAGE SYSTEM. PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(11)MODULES-LG330N1(11)OPTIMIZERS- SOLAREDGE OPTIMIZERS(1)INVERTER-SOLAREDGE SE7600A-USS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45582	12041-10000-14856	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	remodel corridor on the 14th fl of an office buildingplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45583	16041-10000-31924	8332 N SEPULVEDA BLVD UNITS 1-2	91343	6	192B145   355	2654026106	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.22236	-118.46747	PC for TI24 for office area with 1217 sqft. Installing new receptacles and and controls with existing lights. **CHANGE OF USE FROM (E) RETAIL TO OFFICE.  INERIOR TENANT IMPROVEMENT TO COMBINE SUITES 1 AND 2 INTO ONE LARGE OFFICE SPACE.  NO CHANGE IN PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45584	14041-10000-03542	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	Plan check for power only in Dodger Stadium. Scope: cut over of existing feeders from existing old substations to existing new substations previously installed as part of an electrical infrastructure upgrade project. Existing halogen flood lighting is replace with new LED flood lighting in unoccupied void areas.  reference 13041-10000-33114 13041-10000-33117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45585	11041-10000-20033	2069 W SLAUSON AVE	90062	8	108B189  1290	5005012028	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM			PC Approved	09/20/2011 12:00:00 AM	PIN	33.98939403	-118.31555134	ti to an existing commercial building.  plan check only for energy with NO emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45586	19041-10000-26384	9027 N CANOGA AVE STE D	91304	3	195B105    39	2779018039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.23429	-118.59779	Remove HID fixtures and replace with new LED fixtures (Indoor Only) in Suite #D - T24 Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45587	15041-10000-03056	6325 W SANTA MONICA BLVD	90038	13	144B185   700	5533007013	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.09087	-118.32754	New fire alarm system for a change of use from B occupancy to E occupancy (first floor only). work including (1) fire alarm panel, (1) power supply, & (51) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45588	15041-10000-23585	7535 N SAN FERNANDO ROAD	91505	2	186B177   569	2466036009	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM			PC Approved	07/23/2015 12:00:00 AM	ADDRESS	34.2083	-118.35375	PLAN CHECK FOR ENERGY ONLY FOR CONVERTING EXISTING OFFICE TO BATHROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45589	18041-20000-11953	18300 W TARZANA ST	91356	3	168B125     3	2184******	A1-1XL	South Valley	Encino - Tarzana	Tarzana	Yes	1397.03	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Closed	06/01/2018 12:00:00 AM	ADDRESS	34.16154	-118.53164	New entry kiosk/guard house.  Plan check for energy.Building permit under 17010-10000-03755.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45590	19041-20000-53090	17170 W RAYEN ST	91325	12	195B133   219	2690013020	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.23205	-118.50805	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER WITH POWER OPTIMIZERS. () MODULES AND OPTIMIZERS, (2) 7.6KW INVERTERS. TOTAL SYSTEM SIZE IS 15.2KWAC/ 18.87KWDC. FINAL FEES ARE $0 DUE TO SENATE BILL 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45591	15041-10000-33890	311 N GAFFEY ST	90731	15	018B197   703	7447031039	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	33.74529	-118.29249	PC for power and energy. New gas station being constructed in a vacant lot. All equipment is new. Hazardous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45592	12041-10000-20575	1526 N EDGEMONT ST	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.09898	-118.29599	RE-FEED EXISTING EMERGENCY F PANELS THAT IS PRESENTLY SUPPLIED FROM SWITCHBOARD EHG AND ARE TO BE SUPPLIED FROM SWITCHBOARD MR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45593	13041-10000-02721	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM			PC Approved	02/01/2013 12:00:00 AM	ADDRESS	34.07666	-118.3805	450 SQ FT T24. TI IN EXISTING 8-STORY HIGH-RISE LABORATORY RESEARCH BUILDING.  LOW VOLTAGE FIRE ALARM DEVICES ARE EXISTING RELOCATED AND APPLICANT WAS REFERRED TO PULL AN EXPRESS PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45594	11041-20000-12225	752 S MAIN ST	90014	14	127-5A211 211	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Public Safety Only			06/14/2011 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.04283	-118.2527	Plan check for new fire alarm system. Replace existing system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45595	17041-20000-18327	4101 S REDWOOD AVE	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	33.99086	-118.44043	Outdoor parking and site lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45596	16041-20000-12929	19701 W VALDEZ DR	91356	3	165B117    64	2178032007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.15148	-118.56202	Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter, (44) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45597	17041-10000-08105	644 S GLADYS AVE	90021	14	126A213   413	5147030064	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.03913	-118.24292	PC FOR ENERGY. REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 2500 SQ FT. (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45598	10041-10000-02768	400 S HOPE ST	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM			PC Info Complete	02/17/2010 12:00:00 AM	ADDRESS	34.05199	-118.25366	title 24 for one story fast food ,  located on site of high rise. open to street for egress. no emergency lighting required.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45599	19041-10000-09464	3526 W WASHINGTON BLVD	90018	10	126B189   972	5060023004	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.03969	-118.32342	TI IN AN EXISTING COMMERCIAL SPACE. INSTALLING NEW LIGHTS. T-24 ENERGY ONY.TOTAL AREA: 2190 SQR FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45600	18041-20000-06531	21777 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.16858	-118.60238	Plan check for power only. Project site is an existing commercial building. Project scope is the replacement of the service distribution equipment. Service size has remained the same. Existing subpanels will be refed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45601	19041-10000-06055	6325 W SANTA MONICA BLVD 1ST &2ND-FLOORS	90038	13	144B185   700	5533007036	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM			PC Approved	02/20/2019 12:00:00 AM	ADDRESS	34.09087	-118.32754	<<URM>> building. TENANT IMPROVEMENT TO (E) TYPE IIIB SCHOOL BUILDING ( 2-FLOORS )ADDING WALLS LUMINAIRES HVAC UNITS AND BRANCH CIRCUITS TO EXISTING PANELBOARDS. ADDED LOAD IS LESS THAN 200A. TITLE 24 PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45602	16041-20000-21412	19600 W NASHVILLE ST	91311	12	210B117   240	2708022008	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Refund in Progress	07/14/2017 12:00:00 AM	ADDRESS	34.26969	-118.56042	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45603	16041-20000-12875	12121 W BLUFF CREEK DR 3rd Floor	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	33.97874	-118.40463	TI to (E) commercial office space - 938 sq. ft.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45604	18041-10000-29292	4701 E YORK BLVD	90042	14	156A223   126	5474016011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	34.12274	-118.2128	Plan check for power and energy. Service upgrade in a commercial building. Scope includes new service, and (19) panels.BUILDING PERMIT # 18014-10000-03794 ( 4703 E YORK)BUILDING PERMIT # 18016-10000-21413 ( 4701 E YORK)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45605	11041-10000-21709	3025 W SUNSET BLVD 1-3	90026	13	142-5A203 315	5426004005	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.08411	-118.27399	new 3-units apartment building with coffee shop on the first floorplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45606	14041-20000-16333	9415 N TELFAIR AVE	91352	6	198B165   415	2629005005	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.23998	-118.40092	Replacement of fire-damaged 400A service and distribution equipment for a commercial warehouse building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45607	18041-10000-13350	810 E PICO BLVD #222	90021	14	123A211   488	5132019048	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Info Complete	04/13/2018 12:00:00 AM	ADDRESS	34.03119	-118.25079	PC FOR OFFICE TI IN EXISTING BUILDING FOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW PANEL, XFMR, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1935 sq.ft. B#18016-10000-06085	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45608	18041-10000-23114	380 WORLD WAY TBiT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR EXISTING OFFICE SPACE AND CHANGE OF USE FOR EXISTING STORAGE AREA TO  OFFICE AT LEVEL 5BUILDING PERMIT #18016-10000-19684	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45609	17041-20000-10511	13050 W SAN VICENTE BLVD #104	90049	11	129B137   501	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Approved	04/03/2017 12:00:00 AM	ADDRESS	34.0483	-118.49125	Tenant improvement for (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45610	18041-10000-25387	818 W 7TH ST #440	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.04895	-118.25943	PC FOR T-24, TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. WORK INLCUDES NEW LIGHTING AND RECEPTACLES. NO CHANGE IN EXISTING USE OR OCCUPANCY. TOTAL SQ. FT. 3815	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45611	15041-10000-03087	13286 N CRANSTON AVE	91342	7	225B161    55	2512024024	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.31259	-118.41941	PV1, 5KW AC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE,.(16)  MODULES SUNPOWER SPR-327NE-WHT-D (1) INVERTER ABB PV1-5000-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45612	19041-10000-34276	920 S GRAMERCY PL	90019	4	132B193   971	5092023021	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			08/29/2019 12:00:00 AM	09/21/2021 12:00:00 AM		Issued	09/21/2021 12:00:00 AM	ADDRESS	34.0552	-118.31307	Full PC for power and energy. Scope includes a new 800A 120/240 3 phase 4 wire service. Total affected area is 19,726 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45613	15041-20000-35427	18857 W BRAEMORE ROAD	91326	12	216B121   190	2820015010	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.29062	-118.54451	PV1, roof mounted solar 3.8 kW AC system.(11) modules: Q-PEAK-BLK-G3-270W(1) inverter: SE3800A-US (240V)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45614	11041-10000-07161	3650 W MARTIN LUTHER KING, JR BLVD FC 10	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	08/02/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	INTERIOR TENANT BUILD OUT OF SBARRO ITALIAN EATERYWITHIN EXISTING SPACE AT BALDWIN HILLS CRENSHAW PLZ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45615	14041-20000-26580	3701 W WILSHIRE BLVD # 600	90010	10	132B193    27	5503029024	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.06188	-118.30708	TI TO SUITE 600. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45616	16041-10000-41747	4541 W ELECTRONICS PL	90039	13	165B205   121	5593011035	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.14485	-118.2731	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 76250 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45617	14041-20000-15459	2522 S ANCHOVY AVE	90732	15	012B189   529	7563036016	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	33.72529	-118.32118	microinverter enphase m250. using nonstandard plan. total system size 7.9kw ac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45618	18041-10000-20740	1103 S ABBOT KINNEY BLVD	90291	11	108B145  1025	4239022002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	33.99185	-118.47029	PC FOR RETAIL TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA 2515 SQ.FTB#18016-10000-05838	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45619	16041-10000-15328	732 E 110TH ST	90059	8	088-5A207 312	6071007030	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	33.93551	-118.26192	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.0KWDC / 1.72KWAC.(8)MODULES-HYUNDAI HIS-M250MG(8)MICROINVERTERS-ENPHASE M215-60-2LL-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45620	14041-20000-28739	10626 N SWINTON AVE	91344	12	207B137   544	2679008031	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			Corrections Issued	10/16/2014 12:00:00 AM	ADDRESS	34.26343	-118.48582	PV1 SFD. TOTAL SYSTEM SIZE 7.6KW AC USING TRANSFORMERLESS INVERTERS. USING STANDARD PLAN. SYSTEM USES POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45621	18041-10000-10083	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			Corrections Issued	03/20/2018 12:00:00 AM	ADDRESS	34.10311	-118.31242	Plan check for power only, install 500kVA  generator for stand-by power, building is not a highrise.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45622	16041-20000-27009	1905 N ISABEL ST	90065	1	148-5A217 231	5455007030	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.10123	-118.23298	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (28) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45623	12041-20000-27451	9494 W REMBERT LANE	90210	5	153B165   535	4388009018	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.11189	-118.40238	New 10kw rooftop mounted photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45624	16041-20000-23650	1327 S BRINKLEY AVE	90049	11	129B137   239	4407006015	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.05147	-118.49679	Plan check for PV roof mounted system. system size: 15.4kW with 45 modules and 2 inverters(7.7kW) connected to 400A service	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45625	17041-10000-18915	7083 W HOLLYWOOD BLVD 6TH FLR-600, 650	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.10173	-118.34439	PC for T24 only for Office TI. PC for new lights and receptacles. Total area is 2070 sqft. Building #17016-10000-14584	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45626	17041-10000-07521	3544 E OLYMPIC BLVD	90023	14	118-5A225 217	5191020008	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.01864	-118.20134	PC FOR 800A SERVICE UPGRADE. PROVIDING NEW SUBPANEL AND REFEED EXISTING PANELS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45627	17041-10000-18982	2230 N AVON ST	90026	13	144B213   501	5415006056	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Expired	09/17/2023 12:00:00 AM	ADDRESS	34.09104	-118.24566	PC FOR BATTERY STORAGE UNIT. USING TESLA POWERWALL 2.0. SYSTEM IS 5.8KW WITH STORAGE UP TO 13KWH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45628	14041-10002-19813	1630 N SAN PABLO ST	90033	14	135A225    11	5202001004	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM			PC Approved	12/30/2015 12:00:00 AM	ADDRESS	34.06498	-118.20218	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE UPDATED FAULT CURRENT VALUES AND CHANGE TO FEEDER TYPE. ALL CHANGES NOTED DELTA 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45629	13041-10000-35686	20140 W DELITA DR	91364	3	171B113   241	2166010020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Closed	08/19/2014 12:00:00 AM	ADDRESS	34.16494	-118.57323	PV1, Install 8 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US. (32) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45630	16041-10001-27582	550 S HILL ST 1 st floor	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Approved	04/07/2017 12:00:00 AM	ADDRESS	34.04753	-118.25268	04-07-2017 Changes to an approved set of plans. Changes include floor plan lighting fixture layout. Changes has been clouded as delta 2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45631	10041-10000-17154	2700 W COLORADO BLVD # 144	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	34.14248	-118.22438	TI  FOR ICE CREAM STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45632	10041-10000-06335	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM	10/15/2010 12:00:00 AM		Permit Finaled	04/22/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	New office/gym building with two stories.  Plan check for energy and power.  (Methane zone).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45633	18041-20001-44304	8526 N VAN NUYS BLVD	91402	6	192B149   118	2638001044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.22557	-118.44877	04/17/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4.*****Original Scope of Work*****TITLE 24 ONLY FOR A TI OF AN EXISTING COMMERCIAL RETAIL SPACE. TOTAL SQ FT 1092.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45634	15041-10000-37336	9752 N ETON AVE	91311	12	201B105   134	2746004024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.24773	-118.59424	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 9776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45635	18041-10000-23237	8065 N WEBB AVE STE B	91605	6	189B169    98	2310008003	C2-1VL-CUGU, M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Closed	05/12/2021 12:00:00 AM	ADDRESS	34.21748	-118.38966	"PC FOR FIRST TIME TI FOR NEW FRANCHISE RESTAURANT ""BURGERIM"" FOR POWER AND ENERGY. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 1660 SQ.FT B# 18016-10000-19900"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45636	15041-10000-29701	3494 E PICO BLVD	90023	14	118-5A225 320	5190036804	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.0179	-118.20314	PC FOR POWER FOR EXISTING COMMERCIAL (SO. CALIFORNIA GAS COMPANY) BUILDING. SCOPE INCLUDES NEW GENERATORS, SWITCHBOARD, ATS, UPS, PANELS, AND BRANCH CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45637	19041-20000-49620	10880 W WILSHIRE BLVD 850	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.05885	-118.44283	Tenant improvement add new lights and equipments plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45638	17041-20000-29027	8314 W 3RD ST	90048	5	138B173   892	5511031036	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.07259	-118.37057	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is change of use/tenant improvement. Total lighting area = 2,169 sq. ft.Note: Building application has been generated under 17016-10000-07375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45639	16041-10001-03208	5077 N LANKERSHIM BLVD # A	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM			PC Info Complete	09/02/2016 12:00:00 AM	ADDRESS	34.1626	-118.37361	09/02-16 Changes to an approved set of plans. Changes include install additional 1 new panel to comply with disaggregation and changes layout of lighting & receptacle. Changes Apply to delta 3 only. Full plan check for a first time tenant, restaurant, T.I. located in the first floor of a commercial building;updated engineer on record to match what is on plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45640	19041-20000-10004	2018 N VALENTINE ST	90026	13	144A211   287	5420037026	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2019 12:00:00 AM	03/20/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.0879	-118.24896	addition of (1) tesla ESS to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45641	15041-10000-28459	3728 S SOMERSET DR	90016	10	117B185   287	5046025026	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.01915	-118.33718	PV1 INSTALL 7.42 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(28) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45642	18041-10000-37012	8750 N VAN NUYS BLVD	91402	6	195B149   561	2638001053	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.22853	-118.45003	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45643	18041-10000-07066	1850 N CHEROKEE AVE BLDG 1	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.10481	-118.33464	PC for power and energy for change of use from apartment to hotel. Scope includes new 600A service, new panels, lights receptacles and equipment. This building is 1 of 2 for project and consists of 21 units and has main service located outside which also serves building 2.  Total are 10781 sqft. Building 2 # 18041-10000-05773. Building 1 # 18041-10000-05775.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45644	11041-20000-16327	9601 N IRONDALE AVE	91311	12	201B109   283	2748023056	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.24458	-118.58609	new 800 amps service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45645	17041-20000-21261	11755 W WILSHIRE BLVD 22nd Floor	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.04856	-118.46231	Renovation of (E) commercial highrise office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45646	14041-20000-32082	12334 N KENNY DR	91344	12	219B137   129	2609020017	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Expired	01/11/2017 12:00:00 AM	ADDRESS	34.29423	-118.49852	""" 0$ FEES DUE TO SENATE BILL 1222""PV1 INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN ELECTRIC PANEL. 16.32 KW DC/12 KW AC. SYSTEM USES POWER OPTIMIZERS."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45647	17041-10000-29172	9041 N LAUREL CANYON BLVD	91352	6	195B165   118	2629032001	[T][Q]RD2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.23351	-118.40574	NEW 96 UNIT APARTMENT. SENIOR LIVING CENTER. PC FOR POWER AND ENERGY. B#13010-20000-03995	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45648	14041-10000-28255	14500 W SHERMAN CIR	91405	6	183B149   800	2219007034	(T)(Q)RAS3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			10/14/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.19972	-118.44963	Fire alarm system in a new 284 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45649	12041-10000-07881	3624 N WESTFALL DR	91436	5	162B137   628	2293006015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.13662	-118.49358	Plan check 15.84KW roof mounted photovoltaic system for an existing single family dwelling. Additional permit to upgrade existing service panel to 225A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45650	19041-10000-52755	712 S OLIVE ST	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM			PC Info Complete	06/15/2020 12:00:00 AM	ADDRESS	34.0462	-118.25568	FULL PLAN CHECK FOR POWER AND ENERGY FOR A TI TO AN EXISTING BUILDING. SCOPE INCLUDES TWO NEW DISTRIBUTION BOARDS (1200A & 2500A) WITH A 750KVA TRANSFORMER FEEDING SEVERAL ELECTRICAL EQUIPMENT AND 100KW GENERATOR. PER BUILDING PERMIT # 19016-10000-40776	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45651	15041-10000-24196	1138 E 42ND PL	90011	9	114A209   162	5115030008	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Expired	08/22/2017 12:00:00 AM	ADDRESS	34.00653	-118.25551	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(26) KYOCERA KU2606XPA MODULES(1) ABB PVI-6000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45652	19041-10000-37696	6255 W SUNSET BLVD 19th floor	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	Energy plan check for a TI. Scope includes new lighting and equipment with a total lighting area of 14,508-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45653	18041-10000-30248	9777 N TOPANGA CANYON BLVD	91311	12	201B101   201	2727012064	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.24852	-118.60657	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45654	12041-20000-21602	5460 N SEPULVEDA BLVD	91411	2	174B145   713	2250008015	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.17014	-118.4659	Plan check for power and energy. Assembly with 100 or more people. 3324 sqft. New overhead 200A service. Kingdom Hall of Jehovah's Witnesses.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45655	14041-10000-15154	701 E JACKSON ST	90012	14	130-5A217 307	5173016005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.05116	-118.23308	T24, REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 20400 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45656	10041-10000-21173	6310 W SAN VICENTE BLVD	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.06084	-118.36757	Converting existing space into a Dental Office.  T-24 and emergency lighting, and power plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45657	12041-10000-10389	4401 W SUNSET BLVD	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.09708	-118.28526	T.I. to a filming studio, with prop manufacturing.  New 600A and New 800A Switchboards, loads and lighting.  Full plan check for Power and Energy.  Load calculation based on connected load.  Fault current based on calculation and Series rated.  Cut sheet attached to plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45658	10041-10000-22204	18433 W ROSCOE BLVD # 210	91325	12	192B125   578	2786022035	(Q)C1-1VL, (Q)P-1VL	North Valley	Northridge	Northridge South		1154.02	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	ADDRESS	34.22091	-118.53469	Tenant improvement in an existing medical office	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45659	14041-10000-35529	7933 N AJAY DR	91352	2	189B177   302	2407015012	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.21496	-118.36055	Full plan check for power and energy for industrial warehouse and office building T.I. REFER TO NEW ENGINEERED DRAWINGS UNDER PLAN CHECK NUMBER 15014-10000-10965	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45660	18041-10000-25919	8100 W 3RD ST	90048	5	138B177   751	5511029035	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.072	-118.36606	PLAN CHECK FOR TITLE 24 ONLY FOR TI (CHANGE OF USE FROM FLOWER SHOP TO RESTAURANT) FOR NON-HIGHRISE BUILDING. TOTAL AFFECTED AREA = 2200 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45661	19041-10000-47378	1843 W 45TH ST	90062	8	111B193   270	5015001015	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.00289	-118.31278	PLAN CHECK FOR PV1 INSTALLATION WITH AN EXISTING SERVICE OF 200 AMPS. INSTALLTION INCLUDES 16 MODULES (HANWHA Q-CELL), 16 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H-US).SYSTEM SIZE: 5.12 KW DC; 3.80 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45662	14041-10000-06357	7323 N ETHEL AVE	91605	2	186B161   557	2327003016	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.20377	-118.41827	T24, REMOVING HID LIGHT FIXTURES WITH NEW FLORESCENT FIXTURS. TOTAL AREA 4512 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45663	17041-10000-40543	601 E 94TH ST	90003	9	094-5A207 451	6050008006	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	PIN	33.95131279	-118.26495604	PC FOR ROOFMOUNTED PV ON SLD.SYSTEM SIZE 3.08KWACSCOPE INCLUDES 11 MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45664	12041-20000-06598	6600 N TOPANGA CANYON BLVD #1094	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			No Progress	06/08/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T. I. for retail space in exist. Westfield Topanga Mall, 2,131 sq. ft.  P/Check tailored method lighting compliance and emergency egress lighting.  Load < 400A.   Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45665	19041-20000-31960	8748 N REMMET AVE	91304	3	195B105   175	2779041033	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.22962	-118.60011	PV2.  Install 22.57 kW DC grid tied PV system on carport.  (74) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45666	14041-10000-02715	3423 S WADE ST	90066	11	114B153   473	4247019022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			Corrections Issued	01/30/2014 12:00:00 AM	ADDRESS	34.01001	-118.44442	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH 200A MAIN SERVICE PANEL. 3 STRINGS OF (8) MODULES. 6 kW DC SYSTEM, WITH (24) MODULES, (1) FRONIUS #IG 5100 NEG  INVERTER, (1) COMBINER BOX. WORK DONE ON STANDARD CENTRAL INVERTER PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45667	17041-20000-22227	1672 N CLEAR VIEW DR	90210	5	147B153    54	4356005013	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.10214	-118.43445	PLANCHECK ONLY FOR A NEW SINGLE FAMILY RESIDENCE. 600 AMP SERVICE.building permit # 16010-10000-05208	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45668	14041-10001-03880	4143 N BELLINGHAM AVE	91604	2	165B165  1046	2367013041	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.14622	-118.39882	"""EXPEDITED PER APPLICANTS REQUEST""PV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. TWO STORY. SYSTEM SIZE: 5.30 KW DC.(20) SUNIVA # OPT265 (1) POWER-ONE AURORA PV1-5000"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45669	16041-10002-06532	660 S FIGUEROA ST 1 & 6 flr	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/24/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	THIS IS PC FOR CHANGES TO APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE USE OF CHANDLIER OVER 300 POUNDS. STRUCTURAL PLANS AS REFERENCE PROVIDED, PC FOR POWER SYSTEM. UPDATED T24. PC FOR POWER AND ENERGY. PERMIT ALREADY ISSUED FOR ALL ELECTRICAL WORK. THIS IS PC ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45670	17041-30000-03919	2484 E OLYMPIC BLVD	90021	14	121-5A219 158	5168002900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.0254	-118.22674	Plan check for power and energy. Project site is a new administration building and adjoining parking lot for an asphalt plant. Total lighting area = 3,800 sq. ft.Note: Building application has been generated under 16010-10000-05743	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45671	15041-10001-00570	12500 W OSPREY LANE Bldg3-1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/20/2015 12:00:00 AM			PC Approved	08/03/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	Change to approved set by replacing all minihorn with minihorn low frequency(((NEW FIRE ALARM SYSTEM WITH 30 DEVICES AND1  FIRE ALARM PANEL)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45672	11041-10000-05087	16624 W VENTURA BLVD	91436	5	168B137   819	2284007016	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.1578	-118.49544	The scope of work is to install a new 1600 ampere multimeter switch board to replace an existing 800 ampere service of the same class, at an existing commercial building, and installing three sets of parallel conduits only for future tenants, and one feeder for a house panel, and lighting circuits for exterior lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45673	12041-10002-05956	620 W 2ND ST	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Expired	03/24/2015 12:00:00 AM	ADDRESS	34.0545	-118.25027	((((((((( Changed 73 devices to wheellock manufacturer from EST3 Genesis. Device Compatibility is insured.))))))))))SUPPL. PERMIT TO PERMIT #12041-10000-05956 FOR CHANGE OF ADDRESS FROM 221 S GRAND AVE TO 620 W 2ND ST  (NO CHANGE IN LEGAL DESCRIPTION)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45674	14041-10001-29139	12011 W SAN VICENTE BLVD 700	90049	11	129B141   153	4404023019	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Expired	02/07/2017 12:00:00 AM	ADDRESS	34.05243	-118.4735	(((1/13/2015- CHANGES MADE TO APPROVED SET. GENERATOR ON SITE, REMOVED ALL UNIT EQUIPMENT AND CONNECTING LIGHTS AND EXIT SIGNS TO EXISTING GENERATOR EM CIRCUIT. EXIT SIGN FED FROM 2 SOURCES. SCOPE OF PLAN CHECK COVERS DELTA 1 CHANGES ONLY)))OFFICE TENANT IMPROVEMENT (1250 SQ. FT. :PLAN CHK IS FOR TITLE 24NON-HIGH RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45675	10041-10000-07940	4956 E YORK BLVD	90042	1	156A225   300	5477002030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1834.01	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM			PC Info Complete	06/28/2010 12:00:00 AM	ADDRESS	34.12136	-118.20712	New 1 story, 5 units, commercial building. Core & Shell only. Plan Check is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45676	14041-20001-10303	11755 N SEMINOLE CIR	91326	12	213B117    49	2822020019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.28376	-118.55801	Expedite per customer requestPV1. roof-mounted system with 8.01kw, (37) ET solar ET-P660250BB  modules,  (2) tranformerless inverter of SMA AMERICA SB5000TL and SB3800TL 240V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45677	14041-20000-07796	849 W WEST 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.02342	-118.28537	Reroute over 600V feeder over.  Relocate 500KVA, 4800V transformer.  Install new 1200A panels and reconnected of the existing loads.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45678	13041-10000-31594	150 W JEFFERSON BLVD	90007	9	118-5A203 115	5122031001	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.01918	-118.27417	existing services replaced with 800A service and existing swbds become distribution boards;added 2 ea 225A panels to supply new AC UNITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45679	14041-20000-06466	19300 W RINALDI ST M & N	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			PC Approved	04/15/2014 12:00:00 AM	ADDRESS	34.27414	-118.55457	plan check only for change of use from office to retail. new build out. additional load to existing service. pc in accordance to 2008 NEC per building submittal. permit has already been issued under previous TI. this is plan check only application for issued permits. T24 has already been checked((14041-20000-01234, 13041-20000-36040)))NOTE: Per architect, ALL new equipment under the scope of these plans shall be braces for 50Kaic minimum.Inspector shall field verify.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45680	16041-20000-42971	2550 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.10345	-118.25901	TI TO AN EXISTING COMMERCIAL BUILDING ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1752.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45681	19041-20000-44877	11819 W WILSHIRE BLVD	90025	11	129B145   758	4265013087	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	02/21/2020 12:00:00 AM		Issued	02/21/2020 12:00:00 AM	ADDRESS	34.04794	-118.46302	TENANT IMPROVEMENT ADD NEW LIGHTING AND POWER. TOTAL AFFECTED AREA 66,309 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45682	16041-10003-01027	801 S BROADWAY	90014	14	127-5A209 159	5144017028	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.04375	-118.25498	DELTA CHANGES TO APPROVED PLANS.  PLAN CHECK ONLY. PERMIT: 16041-10000-01027<<<PLAN CHECK FOR CORE AND SHELL OF EXISITING BUILDING RENOVATION. GUT COMPLETE BUILDING AND PROVIDE NEW ELECTRICAL DISTRIBUTION THROUGHOUT. NEW 4160 SERVICE WITH CUSTOMER SUBSTATIONS. PLAN CHECK FOR POWER AND ENERGY.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45683	18041-20000-07784	20643 W CHESTNUT CIR (#268)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.2935	-118.58397	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45684	15041-10001-04653			4	147B177  1004	5551026027	C4-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM			PC Approved	04/09/2015 12:00:00 AM	PIN	34.09780421	-118.36117288	Change to approved set by using different lighting fixture.(((Energy plan check for a men & women restroom. Total work area is 271 SQ feet.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45685	19041-20000-52841	2825 N ANGELO DR	90077	5	156B153    95	4382025***	RE15-1-H-RPD-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.12464	-118.44323	PLAN CHECK FOR NEW ESS, (1) BATTERY. ESS SIZE IS 13.2 KWH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45686	16041-10000-02890	303 S VAN NESS AVE	90020	4	135B189   187	5504022026	R3-1XL	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.06874	-118.3153	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING 66 UNIT APARTMENT BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES IN THE COMMUNITY ROOM AND MANAGMENT UNIT. TOTAL AFFECTED AREA IS 20486 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45687	16041-10004-25050	1426 S HAYWORTH AVE	90035	10	129B173   575	5068017016	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.05069	-118.36762	REPLACEMENT OF THE LOST APPROVED PLANS. <<<PLAN CHECK FOR POWER AND ENERGY.  NEW 3-STORY, 8-UNIT APARTMENT BUILDING, OVER ONE LEVEL SUBTERANEAN PARKING. 800 A  3PH-4W SERVICE. TOTAL AREA 7,894 SQ.FT. LOCATED ON METHANE ZONE.>>>B# 14010-10000-04170	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45688	17041-10001-18222	11000 N WESCOTT AVE	91040	7	210B189   194	2551044014	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.26894	-118.3173	Changes to approved set.  Plan check only.  Change PV module to Canadian Solar CS6K-280 and change inverter to Solar Edge SE5000A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45689	12041-10000-21504	1360 S ABBOT KINNEY BLVD	90291	11	108B145  1403	4238004041	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	33.99048	-118.46602	Ti in a retail space. EPC is for T24. Emergency lights are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45690	14041-10000-30387	7350 W MELROSE AVE	90036	5	141B181   614	5526020001	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM			Corrections Issued	11/03/2014 12:00:00 AM	PIN	34.08330039	-118.3499936	Plan check for Title 24 only. Tenant improvement to an existing restaurant. Restaurant is going from a frozen yogurt establishment to a full restaurant. Area = 822 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45691	19041-10000-45334	644 N NORMANDIE AVE 1-12	90004	13	141B197   648	5520003037	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Apartment			11/05/2019 12:00:00 AM			PC Approved	11/13/2019 12:00:00 AM	ADDRESS	34.08253	-118.30031	resubmittale due to lost plans, Plan check for power and energy. New 2-story, 12-unit apartment building over subterranean garage. 800A 120/240V 3ph 4w service. 1 typical unit. T24 area - 8,438sqft.Note. Application is for plan check only. Permit is under original application, 17041-20000-34905.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45692	19041-20000-40441	3272 S GRAND VIEW BLVD	90066	11	117B153   778	4248014023	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.01561	-118.43936	PV1.  Install 17.280 kW DC / 16.043 kW AC roof mounted grid tied PV system.  (48) modules with (2) 7.6 kW rated inverters.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45693	19041-10000-07685	4267 W YOSEMITE WAY	90065	14	159A219   293	5684017014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.12934	-118.22694	PV1 ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTER AND POWER OPTIMZERS. (15 MODULES), ( 15 POWER OPTIMZERS), (1) 3.8 KW INVERTER. TOTAL SYSTEM SIZE 5.4 KW DC AND 3.8 KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45694	16041-10001-21070	5915 W FRANKLIN AVE	90068	4	150A191   170	5586014054	C1-1D	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.1054	-118.31886	CHANGE IN PRINCIPAL DESIGNER. ENGINEER NOW ON RECORD. RECHECKING PLANS FOR COMPLIANCE. PERMIT TO BE ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45695	17041-10000-18457	2029 S CENTURY PARK EAST 14TH FLR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	TITLE 24 FOR TI (RENOVATION TO PUBLIC RESTROOMS ON 14TH FLOOR-HIGH RISE) TOTAL AFFECTED AREA 410 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45696	13041-10001-31529	8419 S TRUXTON AVE	90045	11	096B165   219	4107031007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	33.962	-118.3936	Expedited RSES plan check per applicant request.(((PV1, Install 2.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 11 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45697	19041-10001-50111	2650 N LISCO PL	90046	4	153B177    56	5571011004	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	34.11908	-118.35405	EXPEDITE PER APPLICANT REQUEST.***NEW PV-1 SOLAR SYSTEM. CONSIST OF 204 TESLA SRV3 ROOF TILES, (2) CENTRAL INVERTERS, (DELTA SOLIVIA 5.2 EACH), AND (3) TESLA POWER WALL. SYSTEM SIZE IS 10.4KW AC & 11.92788KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45698	14041-20000-04064	14958 W SEPTO ST PV1	91345	7	201B149   112	2647010042	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.2508	-118.45843	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 125 MAIN SERVICE PNL. TRANSFORMERLESS SYSTEM, SIZED @ 6 kW DC, WITH (24) TRINA SOLAR TSM-250W MODULES, (24) SOLAREDGE OPTIMIZERS OP300-MV, (1) SOLAREDGE INVERTERS, SE6000-US-ZB-U,	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45699	14041-10000-00501	1458 S SAN PEDRO ST #234	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES TO REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 540 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45700	16041-20000-01206	14808 W SATICOY ST	91405	6	186B149   202	2218001011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.20832	-118.45568	PV1. Install roof mounted PV system sized 3.6 kW. Interconnected with main service panel. (15) Kyocera KU2656 Modules(1) ABB PVI 3.6 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45701	13041-20001-23811	162 S ARDMORE AVE	90004	10	138B193  1215	5518002023	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.07196	-118.30152	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING USING 21 MODULES TOTALY SYSTEM SIZE 7KW AC TRANSFORMERLESS INVERTER NONSTANDARD PLAN 3 STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45702	16041-10000-25331	915 W WILSHIRE BLVD 19TH FLR	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.05069	-118.2599	PC for energy only to offices in floor 19th of an existing highrise building. Adding new lighting and power. Total sqft = 4209	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45703	17041-10000-12589	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Issued	05/26/2017 12:00:00 AM	ADDRESS	34.07417	-118.26931	Plan check for power.  Installation of new 2,000 Amp 480/277 Volt switchgear to replace damaged gear.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45704	19041-10000-22456	8501 N FALLBROOK AVE 225	91304	12	192B097   587	2005022006	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.22478	-118.62651	T-24 PLAN CHECK FOR AN INTERIOR OFFICE REMODEL. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1041 SQ.FTB#19016-10000-14431	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45705	17041-10000-05759	514 E C ST	90744	15	027B209    89	7424001056	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	33.77292	-118.25592	Plan check for Title 24 only new 2 story office Building. Total load is less than 400A. Total area: 8,634 sq ft. B# 15010-10000-01854	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45706	16041-10000-11708	14546 W VANOWEN ST	91405	6	180B149    43	2236009018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.1937	-118.45035	TI to an (E) Commercial build. PC for T-24 only. Totl area: 1,025 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45707	13041-20000-24918	1300 N SEPULVEDA BLVD bldg C	90049	5	144B141    26	4368001015	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Info Complete	09/11/2013 12:00:00 AM	ADDRESS	34.08696	-118.47442	energy plan check building C classrooms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45708	15041-10000-07935	8739 S SEPULVEDA BLVD	90045	11	096B165   568	4122001005	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.95773	-118.39645	MINOR INTERIOR REMODEL OF EXISTING BEAUTY DEPARTMENT IN EXISTING SALES AREA.  MINOR UNDER-SLAB ELECTRICAL AND MINOR LIGHTING WORK.  PLAN CHECK FOR ENERGY.  SCOPE OF WORK AFFECTS FEWER THAN 10% OF EXISTING LUMINAIRES IN ENCLOSED SPACE, EXISTING PROVISIONS ARE ACCEPTABLE.  TITLE 24 FORMS INCLUDED AS REFERENCE ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45709	17041-10002-21917	4011 S CENTRAL AVE	90011	9	115-5A209 261	5114010017	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.01063	-118.25682	Changes to an approved set of plan. All changes are clouded. changes include removing/adding kitchen loads and revising service load calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45710	15041-10002-06514	1050 N VINE ST	90038	13	144B189   743	5534022032	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM			PC Approved	06/05/2015 12:00:00 AM	ADDRESS	34.08996	-118.32643	((((6/5/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2 ON THE FLOOR PLANS.  CHANGES INCLUDE REVISIONS TO THE LIGHTING FIXTURES AND REVISING THE ENERGY CALCS.PLAN CHECK FOR ENERGY ONLY FOR TI TO EXISTING RESTAURANT SPACE. NOT A FIRST TIME TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45711	11041-10000-26949	15225 W VANOWEN ST	91405	6	183B145   787	2220020024	C1-1L, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM			Verifications in Progress	03/28/2012 12:00:00 AM	ADDRESS	34.19406	-118.46455	New 4th story medical office building over basement garage.  New service, panels, and standby generator.  Plan check for core and shell only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45712	18041-10000-05746	1404 N CATALINA ST FLR 2-8-+ROOF	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM			PC Info Complete	05/21/2018 12:00:00 AM	ADDRESS	34.09676	-118.29487	Full Plan check  (Power and Energy) for a TI on an (E) Cedars Building, scope only covers 2nd through 8th floor. Add (2) new distribution boards from an existing upstream distribuiton boards, add new panelboards for power and lightings. (B# 17016-10000-24790 & 17016-10000-24791)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45713	11041-10000-05085	1537 N NORFOLK ST 2, 5, & 6-th floors	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM			PC Info Complete	05/17/2011 12:00:00 AM	ADDRESS	34.06138	-118.20223	3 FLOOR ALL INTERIOR, TENANT IMPROVEMENT WORK (NON-STRUCTURAL); 2ND FLOOR - MINOR CONSTRUCTION, NEW FINISHES & LIGHTING, 5TH FLOOR MINOR CONSTRUCTION, NEW FINISHES & LIGHTING, 6TH FLOOR -  ALL NEW CONSTRUCITON (EXISTING SHELL SPACE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45714	18041-20000-16481	11755 W WILSHIRE BLVD #1000	90025	11	129B145   683	4265010192	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for Title 24 only in existing high rise building partial T.I. office space on 10th Floor. Total area: 7,846 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45715	14041-20000-32976	6430 W SUNSET BLVD 8th floor	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.09782	-118.32979	Plan check for energy only. TI to two small offices on the 8th floor of an existing high rise office building. New lighting and receptacle plugs.520sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45716	19041-10000-45631	15729 W STARE ST	91343	12	204B141   895	2661022006	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.25293	-118.47501	Plan check for PV-1 system. system size is 3.200KW, 10 Modules with 10 P320 optimizers and SE3800H central inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45717	18041-20002-08181	11350 W PALMS BLVD	90066	11	117B157   350	4249026028	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.01769	-118.42601	REVISION TO AN APPROVED PV SYSTEM. CHANGES ARE MARKED DELTA 4 CLOUED AREA ONLY. CHANGES INCLUDE SHOWING 2000AMP  SWITCHBOARD. MOVED 3 SOLAR INVERTER TO ROOF. RELOCATE 100AMP SUBPANEL. SHIFTING 11 SOLAR MODULES. PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45718	15041-10001-24106	8224 N WEBB AVE	91605	6	192B169   508	2310005010	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Expired	03/29/2018 12:00:00 AM	ADDRESS	34.22011	-118.39142	PERMIT IS $0 DUE TO SENATE BILL 1222. PV1. PC FOR A NEW PV SYSTEM TO AN EXISTING RESIDENTIAL ROOF-TOP.  TOTAL SYSTEM SIZE IS   7.65KWdc/6.00KWac.(30)MODULES-YINGLI ENERGY YL255P-29B(30)OPTIMIZERS-SOLAREDGE P300 OPTIMIZER  (1)INVERTER-SOLAREDGE SE6000A-US(1)125A SUB PANELNote: Most of the PV equipment were paid under PCIS#15041-70000-24106. Scope includes adding a subpanel to the single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45719	19041-10000-52388	433 S SPRING ST 10TH FL	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	REMODEL OFFICES AND CORRIDORS ON 1OTH FLOORPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45720	16041-10000-38621	8722 S WESTERN AVE	90047	8	096A193    12	6037014027	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	PIN	33.95867756	-118.30867218	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR LIGHTING). TOTAL AREA 60450 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45721	19041-10000-39723	8934 N ENFIELD AVE	91325	12	195B129   180	2768003009	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	10/06/2020 12:00:00 AM	ADDRESS	34.23307	-118.52431	FEES ARE $0 DUE TO ASSEMBLY 1414[EPLAN] PLAN CHECK FOR ROOF MOUNTED 15.2 KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE7600H-US), 39 MODULES USING P400 OPTIMIZERS, AND 2 ESS(TESLA POWERWALL) CONNECTED TO EXISTING 400A SERVICE Install 14.04 KW (DC)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45722	15041-20000-18007	7516 N MILWOOD AVE	91303	3	186B105   309	2112005015	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.20699	-118.59416	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING STANDARD PLAN. TOTAL OF 21 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45723	14041-10000-00942	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.0446	-118.21143	fire al;arm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45724	12041-20000-06067	7703 N DENSMORE AVE	91406	6	189B141   270	2206010006	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM			PC Approved	03/16/2012 12:00:00 AM	ADDRESS	34.21059	-118.47725	"Revisions to 11041-20000-22305 ( "" As build "")"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45725	19041-20000-02153	9508 N JELLICO AVE	91325	12	201B129   446	2755006006	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.24347	-118.51862	Plan check for PV roof mounted system, system size: 10.02KW DC, 10.0KW AC with 34 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45726	19041-20000-50119	20512 W ESMERELDA LANE	91326	12	216B109   199	2701081048	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.29052	-118.58062	PV1. INSTALL 4.36 KW DC PV SYSTEM WITH (13) MODULES AND (1) INVERTER (SE3000)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45727	19041-10001-33906	1814 W JEFFERSON BLVD	90018	8	120B193   704	5041005002	[Q]C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	34.02543	-118.30934	"CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 1 SCOPE OF WORK INCLUDES REIVSIONS TO LIGHTING LAYOUT (ADDITIONAL LIGHTS WERE INSTALLED) T24 FORMS HAVE BEEN UPDATED. NOTE ALL PERMIT FEES TO BE PULLED UNDER 19041-10000-33906. NOTE ADDITIONAL SQUARE FOOTAGE IS CHARGED UNDER 19041-10001-33906 (Building Permit #18016-10000-27839)""COMPLY WITH DEPARTMENT ORDER effective date11/01/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45728	13041-20000-00564	10606 N VARIEL AVE PV-1	91311	12	207B105   342	2706018033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.26273	-118.59279	PV-1. Plan check for pv. Yepez residence. 17.04 kW.  (Additional PC hours for complete system redesign)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45729	13041-10000-20833	735 S FIGUEROA ST #133	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	T.I. REMODEL NON-BEARING INTERIOR PARTITIONS FOR SUITE 133plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45730	19041-10000-46931	10956 W STRATHMORE DR	90024	5	135B149   358	4363008002	[Q]R4-1VL	West Los Angeles	Westwood	North Westwood		2653.05	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.06673	-118.44973	NEW PV1 INSTALLATION WITH A SYSTEM SIZE OF 5.1KW DC/ 3.8KW AC,  WITH 1 CENTRAL INVERTER  (SE-3800H-US), 17 MODULES (HIS-S300RG),  AND 17 POWER OPTIMIZERS (P320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45731	12041-10001-22871	21011 W WARNER CENTER LANE Suite C	91367	3	174B109   133	2149017006	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.17505	-118.59063	Plan check T24 Energy/Emergency lighting tenant improvement for Suite #C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45732	13041-20001-32925	5110 S CRENSHAW BLVD	90043	8	111B185   564	5013019023	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	33.99629	-118.33046	[[[[[[10/23/2014     Changes to approves set of plans. Delta 1 changes only. Changing the service from 120/208 to 120/240 three phase four wire. ]]]]]]Plan check for power and energy for a  MULTI-FAMILY APARTMENT COMPLEX WITH 32 UNITS.Variance is been submitted to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45733	19041-10000-27353	2140 S BUTLER AVE	90025	11	123B153    83	4260004030	(Q)C2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	11/23/2021 12:00:00 AM	ADDRESS	34.03687	-118.44429	Plan check for a fire alarm system located in a 6-story apartment building. Scope includes (1) fire alarm, (4) power supplies, and (205) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45734	17041-10001-17754	737 W 30TH ST ROOF	90007	9	121-5A201 161	5123013006	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.02641	-118.28077	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON EXISTING COMMERCIAL BLDG. SYSTEM CONSIST OF 2 INVERTERS (SOLAR EDGE - SE11400A-US-240V), 64 POWER OPTIMIZERS (SOLAREDGE - P400), AND  64 MODULES (SOLARWORLD - SW345 XL MONO)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45735	10041-20000-17214	5933 W BOWCROFT ST	90016	10	117B173   121	4204008045	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	12/08/2011 12:00:00 AM	ADDRESS	34.01927	-118.37733	Plan check for new installation of 77KW Photovoltaic System connected on the line side.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45736	10041-10000-02707	6249 W 87TH ST	90045	11	096B165   717	4123003026	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM			Verifications in Progress	03/31/2010 12:00:00 AM	ADDRESS	33.95867	-118.39455	First time tenant, for fast food, title 24, power , lighting. existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45737	13041-10000-26217	100 UNIVERSAL CITY PZ stage  #4	0	4	162B177	2424044015	C2-1, PB-1					1437.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM				replacing high bay luminaires -supplied from existing ckts and lighting area ctrls  for shut-off ctrl;EMERGENCY LUMINAIRES REMAINED THE SAME PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45738	15041-30001-37864	5127 S TOWNE AVE	90011	9	108B205    82	5109024034	RD1.5-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM			PC Approved	12/01/2015 12:00:00 AM	ADDRESS	33.99573	-118.26753	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45739	16041-20000-21981	7936 N KEER DR	91335	12	189B125   436	2102015***	(Q)RD6-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21504	-118.53476	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45740	14041-10000-19292	1200 S CLUB VIEW DR 4TH FLOOR	90024	5	135B157   112	4327024***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			07/17/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.06748	-118.42481	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS AND ELECTRICAL ROOM ON THE 4TH FLOOR. 599 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45741	12041-10000-21523	5510 S LINCOLN BLVD	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	33.97299	-118.43051	Ti in the corridor area of 2nd floor of an office BLDG. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45742	18041-10000-08277	8450 N VAN NUYS BLVD	91402	6	192B149   192	2638022039	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	34.22456	-118.44858	Alterations for at a Chase bank- replacing outdoor and indoor luminaires with LED type using existing branch circuitsTotal area is 38907sqft.PLAN CHECK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45743	18041-10001-07066	1850 N CHEROKEE AVE BLDG 1	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM			PC Approved	07/22/2019 12:00:00 AM	ADDRESS	34.10481	-118.33464	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE REVISION TO LIGHTING LAYOUT, FIXTURE MANUFACTURER NO CHANGE IN WATTAGE AND RECEPTACLES. NOTE ALL CHANGES ON DELTA 4 ONLY. PC ONLY.________________________________________________________________PC for power and energy for change of use from apartment to hotel. Scope includes new 600A service, new panels, lights receptacles and equipment. This building is 1 of 2 for project and consists of 21 units and has main service located outside which also serves building 2.  Total are 10781 sqft. Building 2 # 18041-10000-05773. Building 1 # 18041-10000-05775.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45744	13041-10000-15215	1549 N EDGEMONT ST	90027	13	147B197   522	5543007028	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Info Complete	07/24/2013 12:00:00 AM	ADDRESS	34.09963	-118.29642	REPLACING OLD 75 kW EMERGENCY GENERATOR WITH NEW 80 kW GENERATOR. NEW CONDUCATORS WITH EXISTING ATS AND EXISTING CONDUIT. ADDING REMOTE ANNUNCIATOR. GENERATOR IS MOUNTED ON ROOF SERVING PARKING GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45745	19041-20000-35126	18127 W CHATSWORTH ST #B	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	07/23/2020 12:00:00 AM	ADDRESS	34.26469	-118.52657	Plan check for Title 24 only in existing space, Tenant Improvement. Totala area: 996 sq ft. B#19016-20000-21080	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45746	13041-10001-28774	9157 N WILLIS AVE	91402	6	198B149   444	2651006027	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.23726	-118.45538	expedited per applicant request.PV1, Solar syste m installation.Roofmounted, 1 story house, Transformerless, ungrounded, nonstandard plan.sys size 5.25 kw DC(21) TRINA SOLAR # TSM- 250PA05.18\(1) POWER-ONE # AURORA PVI-4.2-OUTD_S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45747	10041-10002-16481	5750 W HOLLYWOOD BLVD	90028	13	148-5A191 157	5586035040	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM			PC Approved	09/13/2010 12:00:00 AM	ADDRESS	34.10154	-118.31491	(4) NEW CIRCUITS FOR CHAIR LIFT, DJ BOOTH. (4) GFI RECEPTACLES IN RESTROOM. (50) LIGHTS, (2) EMERGENCY LIGHTS plan chk is for Title 24 compliance for the luminaires in the corridors and rest rooms for 1st and 2nd floors	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45748	13041-10001-19495	1251 S EDRIS DR 1-5	90035	5	132A167   195	4330024021	RD1.5-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			07/21/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.05575	-118.39818	FIELD REVISIONS : CHANGE TENANT PANELS TO 225A; ,FEEDERS UPSIZED;AND FEEDER BREAKERS CHANGED TO 225A; MAIN HOUSE PANEL CHANGED TO 200A; TO EACH TENANT PANEL ADDED 12KVA STEAM BATH AND 1/2KVA WINE COOLER; DOWNSIZED ELEVATORIN TENANT UNIT TO 4KVA; REMOVED 40HP ELEVATOR(((((((pc for power and energy. NEW 5 UNIT APT 4 STORIES OVER SUB TER. GARAGE. METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45749	16041-20000-45827	1654 S GREENFIELD AVE 1-8	90025	5	129B153   553	4324030010	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			12/30/2016 12:00:00 AM			Reviewed by Supervisor	02/02/2017 12:00:00 AM	ADDRESS	34.04935	-118.4417	Plan check for a PV2 roof-mounted PV system. System size is 19.3 kWac and consists of (77) modules, (77) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45750	14041-10000-01356	770 W WILSHIRE BLVD	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.04914	-118.25811	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT ON 2ND FLOOR REMODEL OF COMPUTER DATA CENTER AND ADDITION OF ROOFTOP EQUIPMENT. NEW DATA EQUIPMENT. PLAN CHECK UNDER 2010 CEC/2008 NEC. BUILDING PERMIT UNDER #13016-70000-26268	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45751	17041-10000-24999	5415 S JANDY PL	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM			Reviewed by Supervisor	08/01/2017 12:00:00 AM	ADDRESS	33.98121	-118.41639	PC FOR RENOVATION OF EXISTING TWO STORYOFFICE AND WAREHOUSE BUILDING TO TWO STORY OFFICE BUILDING.UPDATE ENGINEER OF RECORD.SCOPE INCLUDES NEW SERVICE 800A 480/277WITH NEW PANLES CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA 18877(OUT)+20252(IN)=  39129 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45752	16041-10000-25418	5634 W SANTA MONICA BLVD	90038	13	144B193   768	5536018021	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Issued	10/21/2016 12:00:00 AM	ADDRESS	34.09063	-118.31261	PC FOR POWER AND ENERGY. UPGRADING SERVICE FROM 400A TO 800A  TO AN EXISTING COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS 2818 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45753	14041-10001-28287	8631 W 3RD ST Ste 510	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	Modifications to approved set.  Delta-4 revisions only.  Additional feeder to space to refeed existing loads from existing panel in disrepair to new panel.  Affected sheets: all sheets resubmitted for revised set.  (((T.I. to medical office.  New lighting and recepticles.  Total area = 5685 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45754	14041-10000-16867	11816 N TURTLE SPRINGS LANE	91326	12	216B117   228	2701027009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.28664	-118.56293	PV1. ROOF MOUNTED SOLAR SYSTEM. MICROINVERTED NON STANDARD PLAN. SYSTEM SIZE 8.25 KW DC. (33) TRINA SOLAR  250 MODULES(33) M215-60 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45755	19041-10000-32275	3826 S GRAND VIEW BLVD	90066	11	111B157    29	4235024031	C2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.00425	-118.43046	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45756	16041-10000-39240	1125 W 190TH ST	90248	15	060B197   545	7351028021	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.85848	-118.29593	Full plan check  for a T.I. to existing two story commercial office building.  New lighting and receptacles.  Total area =23,123 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45757	14041-10000-23905	11134 N SEPULVEDA BLVD	91345	7	210B145    89	2664007018	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.27303	-118.46738	PC FOR POWER AND ENERGY. CHANGE OF USE OF EXISTING 2 STORY OFFICE BLDG TO A RESCUE MISSION FOR TEMPORARY HOUSING OF HOMELESS. TOTAL AREA = 13994 SQ FT(INDOOR) + 1631 SQ FT(OUTDOOR).B# 14016-10000-16460.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45758	13041-10000-17942	3530 W WILSHIRE BLVD SUITE 1360	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	34.06154	-118.30122	TI to office suite in highrise building.  New receptacles and lighting in reception room.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45759	19041-20000-30116	9125 N NOBLE AVE #102	91343	7	198B145   466	2656022248	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	11/09/2019 12:00:00 AM	ADDRESS	34.23622	-118.46135	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.095KW DC, 3.6KW AC. SCOPE OF WORK CONSISTS OF (13) MODULES AND 1 INVERTER(3.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45760	12041-10000-26986	12007 W WILSHIRE BLVD	90049	11	129B145  1033	4265014105	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	PIN	34.04586084	-118.46589202	PLAN CHECK FOR ENERGY. TI TO EXISTING RESTAURANT. EXISTING EMERGENCY LIGHTS. 2000 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45761	11041-20000-25760	4167 N FULTON AVE	91423	5	165B157  1002	2373001013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	34.14556	-118.42263	New 6.69 KW roof mounted PV system for a single family residence.  Applicant is using the standard plan for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45762	19041-20000-14102	1981 S HOLT AVE	90034	10	126B169   683	4302025027	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	PIN	34.04134699	-118.38162634	INSTALLING A NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.35KW DC/3.8KW AC. SCOPE OF WORK INCLUDES (15) PV MODULES WITH P320 OPTIMIZERS, AND A SE3800H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45763	16041-20000-10764	822 N SARBONNE ROAD	90077	5	141B149    78	4370002026	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.08479	-118.44904	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.84 KW.  (28) modules with microinverters.  (E) 800 A 120/240V single phase service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45764	16041-10000-39630	6441 W OLYMPIC BLVD	90048	5	132B173   337	5088007027	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.05918	-118.37111	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING 24 MODULES. CENTRAL INVERTER SYSTEM. ROOF MOUNTED	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45765	17041-20000-41332	9901 S LA CIENEGA BLVD	90045	11	090B173    36	4128017045	C2-2, LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	33.94626	-118.37022	ti to an existing commercial building.  adding new lighting new controls to the 1st floor only.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45766	11041-10000-06077	11600 W SHERMAN WAY	91605	6	183B169   692	2320001029	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	10/13/2011 12:00:00 AM	ADDRESS	34.20097	-118.38442	NEW FIRE ALARM SYSTEM. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45767	16041-10000-44007	722 N HUDSON AVE	90038	4	141B185   469	5533035020	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			12/15/2016 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.08418	-118.33193	METHEANE GAS DETECTION LEVEL 5 SYSTEM FOR A NEW 4 STORY 17 UNIT APT WITH SUBTERRANIAN PKG.11 CONTROL DEVICE AND ONE CONTROL PANEL. B # 16010-20000-05171	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45768	15041-20001-28467	17437 W MARILLA ST	91325	12	201B129   207	2755012029	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.24782	-118.51547	Expedite per applicant request(((((Plan check for PV roof mounted system. System size: 10kW with 36 modules and 1 inverter(10.0kW) connected to 400A main panel.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45769	17041-30000-15481	10374 N SEPULVEDA BLVD BLDG 3C	91345	7	207B145   772	2649019009	(T)(Q)C2-1, C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	PIN	34.26013947	-118.46578964	Plan check for power and energy. Project site is a suite within an existing commercial building. Project scope is a first time tenant. Total lighting area = 1,533 sq. ft.Note: Building application has been generated under 17016-20000-00861	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45770	16041-20002-16440	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	"(2/16/2017)changes to an approved set of plans.  Changes noted ""note 23"" Change from fully rated to series rating to reflect existing conditions.  See attached short circuit load study.  This is plan check only.(12/16/2016)CHANGES TO AN APPROVED SET OF PLANS TO REFLCT FIELD CONDITIONS, CHANGES NOTED UNDER DELTA 20.THIS IS PLAN CHECK ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45771	15041-20000-15811	11680 W VICTORY BLVD	91606	2	180B169  1212	2335027002	C1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	34.18651	-118.38718	Plan check for T24 ENERGY ONLY. Tenant improvement to mini mart and addition of office to the building. All work interior to building (no power being routed through/to hazardous location/service pumps). 1,953sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45772	14041-20000-17483	9301 N OAKDALE AVE ste 160	91311	12	198B113   113	2761040019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.23936	-118.56702	Tittle 24 plan check only on a TI for relocating lighting of an area of 665 SQ feet from suite 160.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45773	17041-10000-02012	16513 W OTSEGO ST	91436	5	171B137   238	2259016025	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.16278	-118.4929	PC FOR PV SYSTEM USING 46 AC MODULES. SYSTEM SIZE 15KW AC.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45774	15041-20000-30327	12301 W WILSHIRE BLVD 130	90049	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	PIN	34.04277409	-118.46969044	Plan check for power and Title-24 (energy).  Total area = 916 sq. ft.T.I. to existing medical office (pediatrics) with exam rooms.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45775	13041-10008-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.10155	-118.31097	DELTA  17 CHANGES TO PERMITTED SET OF PLANS-NEW PANEL BOARD ,SHIFTING CIRCUITS AROUND ; ALL CHANGES ARE CLOUDED ON THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45776	19041-20001-32641	12653 W OSBORNE ST	91331	7	204B161     2	2536017906	OS-1VL-CUGU, PF-1VL-O-CUGU, [Q]MR2-1VL-O-CUGU, [T][Q]MR2-1VL-O-CUGU	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			PC Approved	09/18/2019 12:00:00 AM	ADDRESS	34.25491	-118.40888	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING AIRCRAFT HANGER. SYSTEM SIZE IS 58.56KW DC/52.07 KW AC. SCOPE OF WORK CONSISTS OF (183) PV MODULES AND (2) CENTRAL INVERTERS AND A SUB PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45777	16041-10000-37698	1320 E 7TH ST STE 528	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE FOR SUITE 528(2ND FLOOR). TOTAL AFFECTED AREA IS 13155 SQ. FT. B#16016-30000-11408	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45778	10041-10000-05401	6301 W 3RD ST SPACE Q3	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM			PC Info Complete	06/07/2010 12:00:00 AM	ADDRESS	34.07243	-118.35963	energy and title 24 for one story retail store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45779	13041-10001-25425	1452 W CARSON ST	90501	15	051B193   929	7346001068	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	33.83135	-118.30321	Remove old lights and install new lights, outlets at a Mcdonald restaurantplan chk is for title 24 ; permit obtained on 13041-10000-25425	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45780	13041-10002-30631	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.08269	-118.24139	CHANGES TO AN APPROVED SET. NOTE CHANGES ON DELTA 4, SCOPE OF WORK INCLUDES RELOCATION OF ELECTRICAL EQUIPMENT WITH IN THE SAME ROOM. (((Building 1 of 5: Administration Bldg and Clubhouse renovation (rock garden electrical room included under club house).  Install new electrical panels, new convenience receptacles and new indoor and outdoor lighting.  Fire alarm plans included.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45781	14041-20001-33210	6926 N RUBIO AVE	91406	6	183B137   325	2225007020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM			PC Approved	12/06/2014 12:00:00 AM	ADDRESS	34.1964	-118.49556	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. Using 300W power optimizers.29 235W/250W (mixed) pv modules across two strings (14+15).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45782	15041-20001-40831	1501 W 59TH PL	90047	8	105B193   227	6002010019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/30/2015 12:00:00 AM	ADDRESS	33.98682	-118.30255	Experdite per applicant request{{{{{Plan check for PV roof monted system. System size: 5.0 kW with 19 modules 1 inverter(5.0kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45783	16041-10001-10059	17966 W VALLEY VISTA BLVD	91316	5	168B129   370	2182014017	R1-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	34.15789	-118.52419	PC only per inspector. Permit pulled online under 16041-90000-10059.  PV1, 6kW AC system: (24) Axitec AC-260M      (1) SMA SB6000TL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45784	19041-20001-28670	2757 S MOTOR AVE	90064	5	126B165   543	4308010018	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.04162	-118.40352	expediteaddition of (2) tesla ESS rated 5KW to an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45785	12041-10001-03428	5005-5025 S MAIN ST	90037	9	111A203   297	5110024005	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Apartment			09/17/2013 12:00:00 AM			PC Info Complete	12/11/2013 12:00:00 AM	ADDRESS	33.99714	-118.27431	Changes to approved set: delta-4 and delta-5.  Upgrade of house distribution board from 800A to 1000A.  Other associated changes. Also, adding a 8KW range to each apartment.  Submittal per applicant request.  New 89-unit 5 story apartment building with one level of underground parking.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45786	14041-20001-08755	6922 N ORION AVE	91406	6	183B145   530	2234026029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	34.19634	-118.47042	expedited per applicants request.install roof mounted pv system. sysrem size 9.25kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45787	19041-10000-53822	6701 S LA TIJERA BLVD	90045	11	102B173   831	4102001028	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	33.97862	-118.37076	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45788	14041-20000-08393	15836 W LONDELIUS ST	91343	12	195B141   683	2672012048	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.22915	-118.47764	PV1. Roof-mounted PV System with 5.75kw with optimizer	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45789	19041-10000-31817	777 E GAGE AVE	90001	9	105B205   886	6007010011	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	33.98212	-118.26128	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45790	16041-10001-20592	800 S FIGUEROA ST 6th Floor	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	PC only for changes to approved set under 16041-10000-20592. Changes to bathroom area lights. All changes clouded under delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45791	17041-20000-03358	601 W 5TH ST 7th Floor	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Title 24 only. Project site is a portion of the 7th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,112 sq. ft.Note: Building application has been generated under 17016-10000-01424	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45792	12041-10000-15302	144 1/2 N LARCHMONT BLVD	90004	4	138B189   777	5515024002	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.0743	-118.32343	T. I. - Retail Space. P/check for compliance with CEC building energy efficiency standards and emergency egress illumination.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45793	11041-20000-00674	9027 N CANOGA AVE	91304	12	195B105    39	2779018036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	04/11/2011 12:00:00 AM	ADDRESS	34.23429	-118.59779	Plan check T24 Energy (general/emergency) lighting for office TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45794	11041-20000-20231	5000 W WILSHIRE BLVD	90036	4	132B185    15	5507028027	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.06196	-118.33874	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45795	14041-10002-32432	200 WORLD WAY # 231	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Change to an approved set by modifying the floor plan. note. All changes are under delta-3A only.((((5/27/2015)))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES MARKED DELTA 3.  CHANGES INCLUDE REVISIONS TO THE LIGHTING FIXTURES AND ENERGY CALCS.  PC FOR POWER AND ENERGY. TERMINAL 2 STORAGE, REVISING SOME LIGHTING AND ADDING SOME REFRIGERATION EQUIPMENTS AND SMALL OFFICE.(000) TOTAL AREA 215 SQ FT.PLAN CHECKER TO VERIFY THE FEE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45796	14041-20000-04719	5525 N ETIWANDA AVE	91356	3	174B125   518	2160011026	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.17048	-118.53094	T.I. TO UNIT # 112:  pc for t24 energy only. new lighting for medical offices. power to be submittal for full plan check in accordance to article 517 under separate application if applicable.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45797	16041-10000-28341	2051 N HIGHLAND AVE	90068	4	151-5A185 441	5549029011	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Issued	08/15/2016 12:00:00 AM	ADDRESS	34.10806	-118.33738	PC for energy only to existing assisted living facility for the elderly. New branch circuits for lighting and power added. Total Sqft = 3557	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45798	17041-10000-26266	1837 S LA CIENEGA BLVD A	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.04328	-118.37672	PC FOR RETAIL TI  FOR POWER AND ENERGY FOR (MEDICAL OFFICES) WITH EXAMINATION ROOMS. TOTAL AFFECTED AREA 4026 SQ. FTSCOPE INCLUDES NEW LIGHTS RECEPTACLES CIRCUITS AND PANEL.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45799	13041-10001-34186	100 S SANTA FE AVE ste #1000	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Info Complete	08/20/2014 12:00:00 AM	ADDRESS	34.04798	-118.23239	Plan check for power and energy. 1st time tenant. TI for  Metrolink office. 6 story mixed use - not high rise. Located in methane zone.(((((( changes made to previously approved set.  8-15-2014 m.z ))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45800	13041-10002-35964	1361 W 190TH ST STE 120	90248	15	060B193   382	7351001020	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	33.85852	-118.3026	Changes of approved set of plan. Redraw plan form DWP, relocate DWP transformer. Adding 2 new circuies and  7 exterior lights. Plan check only.((((T.I. to existing Autozone store.  New 800A service, panels, branch circuits, and lighting.  Plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45801	15041-20000-27844	3316 S MAIN ST	90011	9	118-5A205 187	5120003009	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	PIN	34.01887477	-118.27203514	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.Plan check for a PV2 roof-mounted PV system. System size is 40 kWac and consists of (4) inverters, (148) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45802	17041-10001-45907	200 N SPRING ST	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Issued	06/26/2019 12:00:00 AM	ADDRESS	34.05405	-118.24317	Change to approved set by with redesign on single line and floor plan. All load originally pull under (1) substation, new proposed plan with all new load is supplied by (4) substation. Total load is still remain the same, most equipment is new.Original plan checker, Mehdi.(((PC FOR POWER FOR A NEW EV CHARGING STATION IN EXISTING PARKING STRUCTRE. SCOPE INCLUDES TAPPING EXISTING SERVICE AND INSTALLING NEW DEDICATED EV DIST. BOARD (600A 480/277V)AND  PANELS INCLUDING EV EQUIPMENT. PROJECT COVERS INSTALLATION ON FLOORS  UL,LL (UPPER LEVEL &LOWER LEVEL))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45803	18041-10000-17636	300 S GRAND AVE FLOOR 39	90071	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.05283	-118.25116	Energy plan check for an office T.I located in the 39th floor of a highrise building. Scope includes new lighting and equipment. Total area is 15,308 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45804	18041-20002-17446	3333 E MISSION ROAD	90031	1	136-5A225 304	5211004019	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	PIN	34.06677133	-118.20531249	03/20/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta A. MSP OCPD rating has been lowered to 250 Amps.*****Previous Work Description*****PLAN CHECK ONLY. CHANGES TO APPROVED SET. FROM FUSED TO NON FUSED AC DISCONNECT, ADDING 200A MAIN BREAKER TO LOAD CENTER, REVEALING ALL BUNDLED PV STRINGS 1-10*****Original Scope of Work*****$0.00 fee due to senate bill 12222 and lb1414Plan check for PV roof mounted system on commercial building, system size: 32.48kWac with 141 modules and 141 microinverters connected to 400A Service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45805	18041-10000-40819	122 N SARATOGA ST	90033	14	127-5A225 356	5180015008	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.04217	-118.20426	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45806	14041-10000-31041	3460 W 8TH ST	90005	10	132B193   621	5093015019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.0575	-118.30559	full plan check for T.I , change of use from retail to restaurant  with new service upgrade to 600-Amp  3-phase 4-wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45807	13041-20000-34599	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	T24 FOR TWO STORY EXISTING OFFICE SPACE. SCOPE OF WORK ON THE FIRST FLOOR. 11000 SQRFT. TOTAL CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45808	15041-10000-11990	100 WORLD WAY TERM-1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	AT LAX, INSTALLATION OF ILLUMINATED SIGN NUMERALS IDENTFYING THE INDIVIDUAL TERMINAL .EACH SIGN NUMERAL WILL BE SUPPLIED FROM A 20-A BRANCH CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45809	14041-20000-11551	24648 W GILMORE ST	91307	12	177B085    42	2032009032	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Expired	05/25/2016 12:00:00 AM	ADDRESS	34.18503	-118.66125	PV1.  Install 9 kW roof-mounted PV system, interconnect with main service panel. Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45810	14041-10000-34342	750 W 7TH ST	90731	15	015B197   473	7451035020	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	33.73798	-118.29338	PLAN CHECK FOR ENERGY ONLY. MACY'S STORE. EMERGENCY LIGHTING, POWER TO GENERATOR.TOTAL AREA 17251 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45811	18041-20000-48500	360 W 6TH ST	90731	15	015B201   100	7455013002	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	33.73886	-118.28479	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,195 sq. ft.Note: Building application has been generated under 18016-40000-40777	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45812	15041-20000-34561	5757 W CENTURY BLVD	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			PC Info Complete	10/16/2015 12:00:00 AM	ADDRESS	33.9457	-118.38274	TI WORK ON 4900 SQ.FT OF THE TOTAL FLOOR AREA. PC FOR T-24 ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45813	14041-20000-34309	17924 W TUSCAN CT	91344	12	219B125     8	2601053012	A1-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Expired	01/05/2017 12:00:00 AM	ADDRESS	34.29982	-118.52542	PV1. CENTRAL/STRING INVERTER STANDARD PLAN. SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45814	16041-10000-32652	3900 W SUNSET BLVD	90029	13	145-5A203 412	5427007001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM			PC Info Complete	11/01/2017 12:00:00 AM	ADDRESS	34.09167	-118.27986	T-24, PC FOR ENERGY ONLY. URM BUILDING TENANT IMPROVEMENT FOR A NEW COFFEE SHOP & RETAIL SHOP. CHANGE IN USE FROM TAKE OUT RESTAURANT TO SEAT-DOWN CAFE. SCOPE  INCLUDES NEW LIGHTS AND RECEPTACLE. TOTAL AFFECTED AREA IS 2322 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45815	18041-10000-08914	140 W ANAHEIM ST #C	90744	15	030B205   411	7423002042	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.77972	-118.26333	Plan check for T24 only, replace indoor and outdoor lighting fixtures to LED luminaires with driver. Egress lighting is not part of this scope. Total area: 3,078 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45816	15041-10001-07468	759 N SPRING ST	90012	1	133-5A215  38	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	PIN	34.06161992	-118.23745547	"12/16/2016 Changes to an approved set of plans. Changes include reduce scope of work, remove indoor lighing and panel ""C"", ""F"", and ""G"", Increase elevator size to 40HP. Changes has been clouded as delta 2{{{{{{Plan check for power and energy , work is on second and third floor. Inspector to verify routing of SEC. Changes on plan include updates to T24, Emergency lighting added for 2nd floor and put on general circuit, and lockon where exception used for unit equipment.}}}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45817	16041-10000-13491	9301 N TAMPA AVE STE 218	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC FOR ENERGY AND POWER. T.I FOR  RESTAURANT I.I.. MAXIMUM OCCPANCY MORE THAN 100. TOTAL AREA 5,927 sq.ft B#16016-10000--08439	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45818	15041-20000-31562	8443 W FOOTHILL BLVD	91040	7	207B189  1094	2555025007	C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Issued	11/23/2015 12:00:00 AM	ADDRESS	34.25987	-118.31721	PV2. Install roof mounted PV system sized 10 kW. Interconnected with main service panel. (2) 5 kW Inverters Ungrounded(40) 270W Modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45819	18041-10001-25310	11749 N SEMINOLE CIR	91326	12	213B117    51	2822020018	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	ADDRESS	34.28369	-118.55824	PLANCHECK ONLY FOR Installation of roof-mounted solar PV system ON SFD TO ADD 2.3 Kw (ACPV) TO EXISTING 7.4 kw (AC) SYSTEM.  EXISTING SYSTEM UNDER 11041-10000-16683.SCOPE INCLUDES 10 MODULES WITH MICROINVERTERS AND NEW LOAD CENTER.TOTAL REVISED SYSTEM SIZE  7.4KWAC  / 8.06KWDCTHIS IS PLANCHECK ONLY! PERMIT PULLED UNDER 18041-90000-25310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45820	14041-20000-21547	20724 W BERGAMO WAY	91326	12	213B109   140	2701052026	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.27682	-118.58462	New roof mounted PV system with combiner box.  Total system size 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45821	12041-20000-19623	2520 W 6TH ST 4TH FLR	90057	1	133-5A203  50	5141006015	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM			Plans on Hold	09/25/2012 12:00:00 AM	ADDRESS	34.06182	-118.28033	***REFUND PENDING***Plan check for power and energy. Place of Assembly. Occupant load is greater than 10694sqft. 4th floor.***REFUND PENDING***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45822	18041-20000-08350	11150 W OLYMPIC BLVD 9th Floor-Corr & RR	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.03956	-118.43857	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,778 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45823	16041-10000-37988	353 S BROADWAY #300	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.04991	-118.24934	Plan check for Title 24 only in existing space T.I. in high-rise building. Total area: 4800 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45824	16041-10000-15853	3900 N STANSBURY AVE	91423	4	162B153  1094	2274027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	Yes	1417.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.14084	-118.44264	INSTALL NEW FIRE ALARM SYSTEM FOR A SCHOOL BUILDING. 99 FA DEVICES AND 34 CONTROL DEVICES;1 FA PANEL, ONE ANNONCIATOR AND 2 CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45825	19041-20000-29036	6033 W CENTURY BLVD ste 1120	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	33.94572	-118.38954	ti to an existing commercial building.  adding new lighting new controls to exisitng panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45826	15041-10000-26434	1101 S FLOWER ST	90015	14	127-5A207 330	5138015***	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Expired	02/02/2024 12:00:00 AM	ADDRESS	34.04284	-118.26457	PC FOR POWER AND ENERGY. NEW MIX USED BLDG 342 UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45827	10041-10000-25429	1231 S LA BREA AVE	90019	10	129B181   217	5084028053	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	10/28/2011 12:00:00 AM	ADDRESS	34.05245	-118.34419	Demolished existing McDonald's restuarant and construct new McDonald's restuarant.  Install new switchboard, panels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45828	13041-10000-33114	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	TI of left field team stores and concessions for Dodger Stadium.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45829	15041-20000-27419	12751 W MILLENNIUM Suite 4140	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total indoor lighting area = 2,190 sq. ft. Total outdoor lighting area = 146 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45830	14041-20000-22544	14277 W MINNEHAHA ST	91345	7	207B153   716	2617012028	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Expired	09/19/2016 12:00:00 AM	ADDRESS	34.26244	-118.44508	PV1.  Install 5.355 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45831	13041-10000-19664	9346 N PASO ROBLES AVE	91325	12	198B133   204	2692022029	RE9-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.24076	-118.5042	PV1-PLAN CHECK FOR ROOF-MOUNTED INSTALLATION WITH 56 MODULES, SYSTEM SIZED AT 14 KW (DC). TRANSFORMERLESS SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45832	17041-20000-13357	2923 S OAKHURST AVE	90034	5	123B165   263	4311010032	R1-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.0357	-118.39537	pv1install roof mounted pv system sized 4.4kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45833	14041-10000-00498	1458 S SAN PEDRO ST #L-04	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES TO REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS.750 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45834	18041-10000-12850	747 E 10TH ST	90021	14	124-5A211 351	5132001085	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.03509	-118.25044	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45835	14041-10000-21912	9451 N MARLEY WAY	91343	7	198B149   631	2650034***	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.24216	-118.45777	PV1 5.886KWdc. 240V. ??? GND. NONstd. 2story. Roofmount. [(1) inverters: {SMA SB6000US-12}]. [(18)modules: {SUNPOWER {spr-327ne-WHT-D}}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45836	19041-20000-34625	18050 W VANOWEN ST	91335	3	180B125    48	2122028013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	12/09/2021 12:00:00 AM	ADDRESS	34.19372	-118.52686	New fire alarm system for (E) commercial building.  (115) devices with FACP and RPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45837	15041-10000-04282	1233 W 257TH ST	90710	15	036B197  1003	7413004041	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	33.79101	-118.29864	Plan check for Title 24 only. Project site is an existing building. Total lighting area = 7376 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45838	10041-10001-20457	1933 S BROADWAY 1ST,5TH-6TH FLRS	90007	9	123A207     2	5126031010	[Q]M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM			PC Info Complete	05/23/2011 12:00:00 AM	ADDRESS	34.03006	-118.26696	FULL TENANT IMPROVEMENT ON EACH FLOOR TO CREATE OFFICES, CONFERENCE ROOMS, RESTROOMS, CALL CENTER AND STORAGE ROOMS.  INCLUDES INTERIOR NON-BEARING WALLS, CEILING SYSTEMS, MILLWORK AND FINISHES.  139,140SFNOTE: PLANS FOR CORE /SHELL MUST BE PLAN-CHECKED APPROVED BEFORE  TI WORK CAN BE APPROVED    <<<<<<<<<<<MODIFICATION TO EXISTING APPROVED SET OF PLANS, ADDED 10 AMPS OF LOAD TO PANEL LSEB1 AND 3 CIRCUITS>>>>>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45839	17041-20001-05882	815 W COLORADO BLVD 2nd Floor	90041	14	163-5A231 107	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM			PC Approved	03/06/2017 12:00:00 AM	ADDRESS	34.14051	-118.18382	Plan check for Title 24 only. Project site is the second floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 958 sq. ft.Note: Building permit has been pulled under 17016-10000-03991	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45840	16041-10000-39896	21820 W MARILLA ST	91311	12	201B105   151	2746016025	[T][Q]MR1-1, [T][Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.24741	-118.60379	PC for energy only. Remove HID fixtures and replace with new LED fixture. Total sqft = 14175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45841	15041-10000-35611	20452 ESMERELDA LANE LOT 53	91326	12	216B109   204	2701082005	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/05/2016 12:00:00 AM	PIN	34.29063501	-118.57983416	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45842	18041-20002-22593	10650 N DE SOTO AVE	91311	12	207B109   345	2706011001	(T)(Q)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.26388	-118.58835	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. REDUCTION IN CONDUIT SIZES ONLY. CLOUDED CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45843	11041-20000-20244	6020 N LANKERSHIM BLVD	91606	2	177B169   631	2338005006	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	09/22/2011 12:00:00 AM	ADDRESS	34.18016	-118.38363	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT HARBOR FREIGHT TOOLS ON EXISTING RETAIL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45844	18041-20000-15733	9708 W OAKMORE ROAD	90035	5	129B165   789	4307017002	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	09/01/2018 12:00:00 AM	ADDRESS	34.0476	-118.39901	Plan check for battery back up system connected to existing PV system in Single Family Dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45845	12041-10000-28787	9640 N SAGEBRUSH AVE	91311	12	201B101   880	2727002027	(Q)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.24553	-118.61615	PV1:  13.44 KW PV system for a single family residence.  Applicant is using the standard plan.  Plan check is over the counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45846	10041-10000-05805	445 S FIGUEROA ST 7th Floor	90071	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00, 2077.10	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.05295	-118.25675	T.I. for a high rise building at 7th floor in R.S.M. and S.P.P. area as indicated on the plans.  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45847	16041-10000-41070	10450 N EL DORADO AVE	91331	7	207B161   445	2620027023	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.26005	-118.41844	PC FOR PV SYSTEM WITH 3.8KW CENTRAL INVERTER SYSTEM AND 18 MODULES. ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45848	17041-10000-36613	1660 W ANAHEIM ST	90744	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	PIN	33.77837751	-118.28848326	"PC for power for new 700HP cooling tower in oil refinery(hazardous location). Cooling tower is fed from cable tray that transitions into conduit and is fed from section G113A from 4160V med voltage substation. Relay panel MUL. 469 is connected to cooling tower conductors and is coordinated with breaker ""52"" and controlled by start stop switch. Building# 17020-10000-01947"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45849	13041-20001-06172	20700 W NORTHRIDGE ROAD	91311	12	210B113    53	2707002001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.27146	-118.57213	[[[[2/24/15 CHANGES TO APPROVED SET. PLANCHECK ONLY. REMOVING GUEST HOUSE. RELOCATING LOADS ON EXISTING PANELSCHEDULES AND RELOCATION 3 PANELBOARDS ]]]]]Total rework of electrical for an existing single family residence.  New 1200 amp service, circuits, loads.  Full plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45850	19041-10000-00686	2405 E POMEROY AVE	90033	14	130-5A225  15	5177006036	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2032.00	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM	06/27/2022 12:00:00 AM		Permit Finaled	08/16/2023 12:00:00 AM	ADDRESS	34.05366	-118.203	METHANE MITIGATION AND DETECTION SYSTEM FOR NEW HOTEL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45851	19041-10000-41415	2121 S AVENUE OF THE STARS STE 2480	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Info Complete	10/11/2019 12:00:00 AM	ADDRESS	34.05554	-118.41342	T-24 PLAN CHECK FOR A TI TO EXPAND (E) OFFICE SUITE 2480. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1679 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45852	16041-10005-34516	6677 W SANTA MONICA BLVD	90038	4	144B185   674	5532022010	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	12/18/2020 12:00:00 AM	ADDRESS	34.09085	-118.33573	CHANGES TO APPROVED SET OF PLANS UNDER DELTA 2 ONLY - CHANGES INCLUDE REVISION TO SINGLE LINE DIAGRAM, CHANGES FEEDERS MATERIAL FROM COPPER TO ALUMINUM, RELOCATION OF LOADS, ADDITION OF NEW LOADS, AND UPDATE OF LOAD SUMMARY.     ORIGINAL PERMIT <<<Plan check for Power and Energey for (new) 695 units apartment with 24,900 SF of retail, 5 stories. There are (5) services in compliance with article 230.2(C).>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45853	18041-30000-35988	6801 W HOLLYWOOD BLVD A1-103	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	34.10229	-118.33907	PC FOR RESTAURANT TI FOR T-24 ENERGY ONLY IN A HIGH RISE BUILDNG (SHARED PODIUM). SCOPE INCLUDES NEW PANEL, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 451 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45854	16041-10001-06545	3322 W WILSHIRE BLVD	90010	10	132B197    69	5094007021	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.06156	-118.29485	Change to approved set by modifying the single line with new breakers, updating emergency lighting fixture, replacing cook top unit with 8kw range, and all T-24 being updated. All changes are being clouded with delta -4 only.. Adding total of 30 branch circuits Fees under submittal 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45855	14041-20000-26632	7721 N CALLE MARIA	91306	3	189B117  1027	2106012104		North Valley				1341.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.21145	-118.56298	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(9) KYOCERA KD255 MODULES(1) SOLAREDGE SE 3000 INVERTER(9) POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45856	17041-10001-02643	10700 W SANTA MONICA BLVD #130	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	34.05167	-118.432	"Change to approved set of plans. Changes under delta 1. Change of light fixture from 6"" recessed light to 4"" fixture."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45857	19041-20001-53525	4832 N ALMIDOR AVE	91364	3	168B093   141	2074040013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM			PC Approved	01/21/2020 12:00:00 AM	ADDRESS	34.15822	-118.63338	PV1. INSTALL 14.85 KW DC ROOF MOUNTED PV SYSTEM WITH (45) MODULES AND MICROINVERTERS (ENPHASE IQ7X-96-2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45858	17041-20000-28477	4105 S REDWOOD AVE bldg 5	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	PIN	33.99074144	-118.44097396	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 10,840 sq. ft.Note: Building application has been generated under 17016-10000-22851	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45859	17041-20000-08196	11258 W NEBRASKA AVE 1-5	90025	11	126B153   247	4261020004	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			03/14/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.04413	-118.44561	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.25 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45860	13041-20000-07155	9535 N ALDEA AVE	91325	12	201B133   606	2692016011	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.24409	-118.50914	Photovoltaic system on roof of single family dwelling.  Two inverters, 70 modules, one photovoltaic subpanel, and one new solar ready service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45861	18041-20001-21197	9910 N BARTEE AVE	91331	6	201B157   115	2645006043	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM	ADDRESS	34.25051	-118.43188	08-27-2018 Changes to an approved set of plans, changes include addition of main circuit breaker to load center and add circuit breaker at battery disconnecting mean. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45862	15041-20003-28493	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.24143	-118.56249	12.23.2015 - Plan check for modifications to approved set of plans - delta 5 changes only. Adding a new 30kVA - 400Hz converter(Variance has been submitted for approval prior to equipment listing), 400Hz distribution panel, and 400Hz branch circuits serving lab (incl. receptacles). *****Previous Work Description*****12/23/2015 Changes to an approved set of plans. Changes include revisions of power plan and the addition loads. All changes have been clouded and marked as Delta 1, 3, and 4.*****Previous Work Description*****Plan check for power and energy for T.I. work within existing space. Total indoor area: 4,536 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45863	14041-20001-24799	7000 S HOOVER ST Unit #4	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	expedite feesNew roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #4.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45864	12041-10000-19031	6161 N SEPULVEDA BLVD	91411	5, 6	168B141   685	2283006001	C4-1L, M1-1L	South Valley	Encino - Tarzana, Van Nuys - North Sherman Oaks	Encino, Van Nuys		1277.10, 1414.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.1821	-118.46652	New Fire Alarm system for a new commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45865	12041-10000-07526	123-127 S LA BREA AVE	90036	5	138B181   965	5513019012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	11/07/2012 12:00:00 AM	ADDRESS	34.07284	-118.34424	PLAN CHECK POWER AND ENERGY FOR NEW CORE & SHELL WORK; NEW 800A SERVICE. 127 S. LA BREA WILL BE CHANGE OF USE FROM RETAIL TO RESTAURANT, 123-125 LA BREA WILL BE CHANGED TO RESTAURANT. (BUILDING D) SITE IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45866	15041-20001-43767	4094 S GLENCOE AVE	90292	11	108B153  1063	4230006003	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	33.99	-118.44273	Revisions to approved set of plans.  Delta-1 revisions only.  Reduction of scope to exclude interior lighting (under separate permit).  Minimum Title 24 Part 6 plan check fee charged.    (((PC for Energy Only. Total area: 15,462sq.ft.  CHANGE OF USE AND NEW INTERIOR SECOND LEVEL ADDITION FROM WAREHOUSE TO OFFICE))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45867	19041-20000-19096	950 S BERENDO ST	90006	10	132B197  1131	5078008035	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Apartment			05/21/2019 12:00:00 AM			PC Info Complete	02/10/2020 12:00:00 AM	ADDRESS	34.05416	-118.29358	1600A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.  Associated building permit under 18010-10000-00890.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45868	16041-10000-41067	10370 N SEPULVEDA BLVD SUITE 3D	91345	7	204B145   126	2649019009	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.25912	-118.46707	FULL PC FOR POWER AND ENERGY. TI TO A NEW SHELL SPACE FOR A RESTUARANT USE. ASSEMBLY OCCUPANT LOAD >100. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND  NEW LIGHTS FOR A RESTAURANT SPACE. TOTAL AFFECTED AREA IS 2294 SQ. FT. B#16016-10000-27926	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45869	16041-20001-24483	10701 W BELLAGIO ROAD	90077	5	141B149   317	4362003039	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.08153	-118.44866	07-18-2018 Changes to an approved set of plan. Changes include: specified utility fault current changed from 100kA to 30kA, infratech heaters removed, steamer relocated, relocated AC units, additional 2 AC panels, removed Pool panel, and all feeders changed to Aluminum. All Changes has been clouded.Plan check only, electrical permit issued under building permit 14010-30000-03038.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45870	14041-20000-04624	11035 N LANGMUIR AVE	91040	7	210B193   548	2551041030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.26979	-118.30942	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45871	16041-10000-11274	2101 E PACIFIC COAST HWY WHTU	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	11/30/2017 12:00:00 AM		Issued	11/30/2017 12:00:00 AM	ADDRESS	33.79173	-118.23549	***Application Withdrawn per applicant's request. Change of Contractor. New Permit#: 19041-10000-44344***PC FOR POWER.MEDIUM VOLTAGE. INSTALLING 4 NEW MOTORS FOR TESORO REFINERY. WHTU PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45872	15041-10001-02311	9030 S LOYOLA BLVD	90045	11	096B161   822	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM			PC Approved	07/02/2015 12:00:00 AM	ADDRESS	33.95663	-118.41787	PC FOR POWER. REVISION TO APPROVED SET OF PLAN. ADDITIONAL LOAD IN THE KITHCHEN AREA INCLUDING INCREASE TRANSFORMER SIZE FROM 75 TO 150 KVA AND PANEL  FROM 225 TO 600A.PC FOR POWER AND ENERGY. DORMATORY AND ACADEMIC CLASSROOM BUILDING FOR OTIS COLLEGE OF ART AND DESIGN. TOTAL AREA  82,013SF. Fire alarm variance filed on 4/2/2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45873	15041-10000-38835	5328 W HOMESIDE AVE	90016	10	120B177   531	5043023007	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Expired	01/03/2018 12:00:00 AM	ADDRESS	34.02697	-118.36158	PV1,  4.3kw roof-mounted system; Scope includes (20) REC Peak Energy BLK Series REC255PE modules ,(20) Enphase M215 microinverter and (1) load center interconnecting through the mainservice Panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45874	12041-20000-02209	1055 W 7TH ST 4th fl.	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			01/30/2012 12:00:00 AM			PC Approved	01/30/2012 12:00:00 AM	ADDRESS	34.0507	-118.26334	OFFICE T.I.ENERGY, EMERGENCYFire/ Life safety 11041-10000-09545	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45875	18041-10000-06700	744 S MARIPOSA AVE	90005	10	132B197   381	5094006004	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.05847	-118.29858	PC FOR A NEW 31 UNIT, 6 STORY APPARTMENT BUILDING. SCOPE INCLUDES NEWSERVICE RATED AT 1200A 3P 120/208V, NEW PANELS, CIRCUITS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA 17828 SQ.FT. B# 17010-10000-02605FIRE MODIFICATION HAS BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45876	17041-10000-02267	9454 N CORBIN AVE	91324	12	198B117    78	2761036055	C4-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.24221	-118.56212	PC for outdoor Tile 24 only. Remove HID fixtures and replace with new LED fixtures. Area: 13,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45877	14041-10000-15262	240 W ADAMS BLVD	90007	9	121-5A205 201	5122013015	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.02619	-118.27205	PLAN CHECK FOR  POWER AND ENERGY. T.I. CHANGING FROM RESTURANT TO SEVEN ELEVEN STORE. NEW 400  A SERVICE,  4 NEW SUB PANELS.TAILORED METHOD.TOTAL AREA 2080 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45878	19041-20000-00837	14537 W DICKENS ST	91403	4	166-5A151 158	2276001022	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Apartment			01/08/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	ADDRESS	34.1503	-118.45018	service upgrade 600 amps to an existing apartment building reconnect to existing unit panels.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45879	19041-10000-42973	1763 W CENTURY BLVD	90047	8	091-5A193  50	6055021066	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	33.94562	-118.30845	Energy plan check for a T.I. Scope includes new lighting and equipment with a total lighting area of 1661-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45880	17041-10000-24571	2186 E CENTURY BLVD 101-302	90002	15	091-5A217 111	6046019929	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/11/2020 12:00:00 AM	ADDRESS	33.94631	-118.23302	POWER PLAN CHECK FOR  3-STORY, 13-UNIT APARTMENT BUILDING; SCOPE INCLDUING A 600A SERVICE AND (14) PANELS. NOTE, THIS BUILDING IS ONE OF THE (16) BUILDING ON THE SAME SITE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45881	10041-10000-25675	6022 W AVION DR	90045	6	090B165    36	4129028900	M2-1	West Los Angeles				2780.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	33.94182	-118.39269	PROVIDING ELECTRICAL  POWER  FOR USE OF AIRPLANES WHICH WILL USE THE EXPANDED APRON/RAMP; NEW FEEDER TO 800A DISTRIBUTION BOARD TO SUPPLY ELECTRICAL EQUIPMENT AT 9 GATES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45882	12041-20000-06349	5415 S JANDY PL	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	33.98121	-118.41639	Permit for 41 new branch circuits. four utilization equipment under 3kVA.  One 0-200A service. One 3.1 -5 kVA equipment. TI for media arts lab (Office). T-24 for Energy and emergency. 5363 sqft. 2 story building. Scope of work is mostly on 2nd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45883	14041-10000-17430	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN REVIEW OF RFI FILES FOR CHANGES ON SITE DURING THE BRADLEY  RENOVATIONS-Areas C12 and C9. ATTACH IS A LIST OF CHANGES FOR ARAEA C12; IN area C 9 INCREASE HP OF A MOTOR AND ADDED A STARTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45884	18041-20000-15902	14558 W ERWIN ST	91411	6	178-5A151 265	2241013032	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			04/30/2018 12:00:00 AM			PC Info Complete	04/29/2019 12:00:00 AM	ADDRESS	34.18351	-118.45074	Plan check for power and energy. Project site is a new 4-story, 24-unit apartment building with 1 level of subterranean parking garage. Work includes a 1,200-amp service and a total lighting area of 24,078 sq. ft.Note: Building application has been generated under 17010-10000-01692	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45885	16041-20000-29617	5250 N LANKERSHIM BLVD Ste 720	91601	2	171B173   367	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.16668	-118.37545	TI to (E) 7th story commercial office space in a commercial highrise building.  Plan check for energy.  7897 sq ft.  Existing emergency egress lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45886	19041-10000-15790	19900 W VENTURA BLVD	91364	3	174B113   424	2164001035	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.17204	-118.56636	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45887	19041-10000-42960	6471 W 84TH ST	90045	11	096B165    16	4108011016	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	33.96304	-118.40161	NEW ROOF MOUNTED 6.3 (DC) KW, WITH 17 SOLAR MODULES AND A POWER WALL BATTERY SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45888	13041-20002-27224	12645 W BEATRICE ST	90066	11	105B161  1007	4211006011	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Reviewed by Supervisor	07/08/2014 12:00:00 AM	ADDRESS	33.98004	-118.41736	Upgrade to new 1600A main service panel. Subfeed old 1000A main panel from new main.[[[New 1000 amp distribution board, new panels, circuits, reconnect loads and lighting to an existing 1-story office building.]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45889	17041-10000-07184	189 S THE GROVE DR C-10	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN ALTERED RESTAURANT SPACE. TOTAL AFFECTED AREA IS 2135 SQ. FT. B#17016-10000-03719	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45890	16041-20000-06285	5750 W WILSHIRE BLVD 5th Floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.06227	-118.3542	FULL PC TO A TI IN AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING, LOAD AND A DISTRIBUTION BOARD 'DB5'WITH A UPS SYSTEM.  TOTAL SQ. FT. 35,733.Note: Building application has been generated under 16016-10000-03467	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45891	12041-20001-01119	11630 W MORAGA LANE Main-House	90049	5	144B145   268	4368002008	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.08705	-118.46821	(((SUPPLEMENTAL APPLICATION FOR RELOCATION OF SERVICE EQUIPMENT. NO CHANGE IN LOADS OR OTHER EQUIPMENT. NEW LOCATION INSIDE GARAGE. )))Plan check for new single family dwelling and for new guest house.  The guest house will be permitted on application number 12041-20000-04868.  This application will be the permit for the main house.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45892	11041-20000-15796	1636 S BEVERLY GLEN BLVD	90024	5	148-5A153 421	4371043013	RE15-1, [Q]R3-1-O	West Los Angeles	Bel Air - Beverly Crest, Westwood	Bel Air - Beverly Crest	YES	2612.00, 2657.00	Electrical	Electrical	Public Safety Only			07/27/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.05899	-118.42473	New fire alarm system for new 16 unit 4 story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45893	19041-10000-48929	14415 W SYLVAN ST	91401	6	178-5A151 115	2240002900	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	04/08/2021 12:00:00 AM	ADDRESS	34.1848	-118.44714	Energy plan check only, area of scope 2657sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45894	13041-10000-06209	2500 W 8TH ST	90057	1	132A201   120	5141025024	C2-1	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.0567	-118.28227	Energy and power for a change of use from a retail space to a dentist's office/healthcare facility inside of a 2-story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45895	19041-10000-45787	7521 W MULHOLLAND DR	90046	4	156B177   188	2427005037	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM			Verifications in Progress	01/16/2020 12:00:00 AM	ADDRESS	34.12575	-118.35915	(E-PLAN)INSTALLATION OF 2 POWERWALL'S AND 1 PANEL OF 200 AMPS FOR AN EXISTING SOLAR SYSTEM WITH AN EXISTING SERVICE OF 600 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45896	15041-10001-05234	100 N LA CIENEGA BLVD #C240	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.07466	-118.37629	Revisions to permitted set of plans. Panel L3 is added as a subpanel to L1. Some circuits from panel L1 are supplied from L3. All changes are clouded and identified as Delta 5(((((((((Full plan check for a first time tenant in a 2-story retail commercial building; Total area is 26187 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45897	17041-20001-15563	309 S BUNDY DR	90049	11	132B141   521	4404011011	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.05753	-118.47648	expeditepv1install roof mounted pv system sized 3.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45898	11041-20000-03411	1880 CENTURY PARK EAST # 404	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	energy plan check # 404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45899	19041-10000-28949	2911 W EXPOSITION PL Units4	90018	10	117B185  1312	5044011026	CM-1-SP, RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02047	-118.32807	Plan check for a PV2 3.00kw AC / 2.6KW DC  roofmounted system with (1) inverter and  (8) modules interconnecting through the main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45900	18041-10000-34327	2936 N MONTCALM AVE	90046	4	156B177   219	2427010001	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.12436	-118.3544	PLAN CHECK ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 8.4KVA SYSTEM CONSISTING OF 24 AC MODULES(SPR-X21-350-BLK-D-AC)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45901	19041-20000-25639	7246 N RHEA AVE	91335	3	186B121  1027	2118019003	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.20258	-118.54135	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS  3.99KW DC/3.8KW AC. SCOPE OF WORK INCLUDES (14) CERTAINTEED PV MODULES WITH P320 OPTIMIZERS, A SE3800H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45902	12041-20000-11577	14117 W HUBBARD ST unit 4	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	34.29849	-118.44081	Ti first time tenant. Plan check for power, energy, and emergency lighting. 1635 conditioned floor area. single story commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45903	17041-20000-34743	15910 W VENTURA BLVD 11TH FLOOR	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.15561	-118.47969	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COMMERCIAL RESTROOM. 161 SQFT. 11TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45904	17041-10000-14938	14432 W HATTERAS ST	91401	4	174B149   322	2245006047	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.17558	-118.44761	PC for energy only , Outdoor title-24 only. Removing existing hid fixtures and installing new LED ones. Area: 31000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45905	17041-10000-03136	2029 S CENTURY PARK EAST 9th floor-LOBBY	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY. Interior renovation of  lobby on the 9th floor, TOTAL AREA 295 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45906	11041-10000-20028	4051 S AVALON BLVD	90011	9	115-5A207 368	5113003013	M1-1	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.00996	-118.26553	"PROPOSED 42'-7"" X 83' (3,368 SQ FT) SELF SERVICE LAUNDROMAT WITH ATTACHED 20'-0"" X 111-7"" (2455 SQ FT) CAR WASH/AUTOMOBILE LAUNDRY AND ATTACHED18'-0"" X 109'-8"" (1,974 SQ FT) VACUUM SERVICE FOR CAR LAUNDRY, SELF SERVICE. TYPE V-B CONSTRUCTION AND ""B"" OCCUPANCY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45907	15041-10000-39389	210 W 57TH ST	90037	9	108B201  1117	5101025008	R2-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Expired	12/25/2017 12:00:00 AM	ADDRESS	33.99038	-118.27656	PV1 roof mounted installation for a single family home. (1) inverter: 6kw. (27) solar modules. (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45908	15041-10003-39687	5011 S NORMANDIE AVE	90062	8	111B193  1129	5016031024	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	PIN	33.99786079	-118.30049597	04/22/16Changes to an approved set of plans. Changes include adding a new solar center and a New AC disconnectNote: permit paid under PCIS#15041-10003-39687((((PV1, ROOF MOUNTED SOLAR SYSTEM. 21 MODULES AND 1 INVERTER. TOTAL SIZE: 7KW-AC.(21) SUNPOWER SPR-327-NE-WHT-D(1) SMA AMERICA SB700TL-US-22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45909	16041-10001-27474	447 S HEWITT ST	90013	14	127-5A215 356	5163022017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.04216	-118.23526	Supplemental PC for T24 only per applicants request. Installing new sub-meter and receptacle. Changes clouded under delta 5.**Title 24 plan check only.  Total area = 4,456 sq. ft.  Two new panels with associated lighting and receptacle loads.  CHANGE OF USE FROM ARTIST IN RESIDENCE TO OFFICE ON THE SECOND FLOOR AND A SMALL SPACE ON THE GROUND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45910	14041-20000-24914	7014 S HOOVER ST UNIT 6	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 6.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45911	13041-10000-14623	8120 N WOODMAN AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.21871	-118.43098	FA FOR SOUTH SPECIALTY MEDICAL OFFICE BUILDING (kaiser panorama city medical center). 455 devices and 1 facp. 5 battery panels and 2 annunciators	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45912	18041-10000-43337	1875 S CENTURY PARK EAST 520	90067	5	132B161    30	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.06115	-118.41457	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 2240 SQFT AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45913	11041-20000-01777	20235 W BAHAMA ST	91311	12	195B113    43	2781035030	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	05/27/2011 12:00:00 AM	ADDRESS	34.23305	-118.57458	T.I. to existing space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45914	14041-10000-35911	1707 E MAURETANIA ST	90744	15	036B213   539	7425025021	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.79051	-118.24214	Plan check for Title-24 only. Remove HID light fixtures and replace with new LED fixture. Total area: 2176SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45915	16041-10000-11821	11458 W BURBANK BLVD 1-40	91601	2	174B169   844	2350004038	C4-1, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.17199	-118.38088	((4/5/2016))THIS IS PLAN CHECK FOR POWER ONLY.  REFERENCE APPLICATION NUMBER 15041-10000-15579 FOR PERMIT FESS.  REPLACING 30AMP MAIN WIRES AND SUBPANELS TO A 50AMP FOR EACH UNIT.  REFER TO PERMIT #15044-10000-02500 FOR 2ND TRADE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45916	14041-20000-15831	3 S CHESTER PL B124A-B124B	90007	1	123A203   124	5124029016	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.03141	-118.27736	Tittle 24 plan check only on two class room area of 1099 SQ feet inside a campus building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45917	13041-20000-20221	9740 N BABBITT AVE	91325	12	201B133   334	2692023031	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.24783	-118.51022	New rooftop PV system for an existing single family residence.  System is Ungrounded and uses Power Optimizers.  Service and panel upgrade are included in Permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45918	19041-20000-12012	333 S HOPE ST 40TH FLR-STE 4025	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	TI to (E) commercial office space in highrise building.  Plan check for energy.Building permit under 19016-10000-06911.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45919	19041-20000-49380	5133 N BILOXI AVE	91601	4	171B177   787	2419021004	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.16412	-118.3584	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER INTERCONNECTED WITH POWER OPTIMIZERS AND A DC COUPLED BATTERY SYSTEM(5KW). TOTAL OF (23) MODULES, POWER OPTIMIZERS AND (1) 7.6 INVERTER. TOTAL SYSTEM SIZE IS 7.36KWDC AND 7.6KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45920	16041-20000-45739	1107 S ALVARADO ST Suite 104	90006	1	130-5A201 307	5136018020	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.05001	-118.28118	Plan check for power and energy. TI to existing commercial laundry facility. >400A of new load. New lighting (incl. emergency). 3,402sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45921	15041-10006-10619	125 W 4TH ST	90013	14	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM			PC Approved	06/25/2019 12:00:00 AM	ADDRESS	34.0488	-118.24807	"DELTA ""1"" CHANGES TO APPROVED PLANS. THE EXISTING 20HP FIRE PUMP IS CONNECTED TO A DIESEL GENERATOR AND DOES NOT NEED TO BE CONNECTED TO THE POWER SYSTEM. THE LOCATION OF THE DIESEL GENERATOR (AND FUEL TANK) WAS APPROVED BY LAFD & SIZE OF THE 20HP FIRE PUMP WAS APPROVED BY MPC, SUBJECT TO FIELD INSPECTION.<<<<CONVERSION OF AN EXISTING 10 STORY OFFICE/BUILDING TO 188 LIVE/WORK UNITS, MIXED USED WITH RETAIL AND RESTAURANTS AT THE LOWER LEVEL. TWO SERVICES, PC FOR POWER AND ENERGY. BUILDING SUBMITTAL DATE BEFORE JULY 1, 2014 - 2008 ENERGY STANDARDS APPLIES.  TOTAL SQ.FT 63,152, FIRE VARIANCE ON FILE.>>>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45922	14041-10001-02668	8019 N LEMONA AVE	91402	6	189B145   258	2209019008	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			Reviewed by Supervisor	02/11/2014 12:00:00 AM	ADDRESS	34.21663	-118.46025	Expedited RSES plan check per applicant request.{{PV1, Install 3 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3000A-US-ZB-U. (12) Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45923	16041-10001-14565	1616 W 209TH ST	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	33.84074	-118.3073	CHECKING FOR CHANGE IN POI. UPGRADING MAIN SERVICE TO 400 WITH MULTI METER BANK. PLAN SHOWS PV INTERCONNECT TO UNIT SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45924	17041-10000-45002	3160 W GENEVA ST	90020	13	136-5A201 258	5501023013	R1-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			12/14/2017 12:00:00 AM			PC Info Complete	09/25/2018 12:00:00 AM	ADDRESS	34.06757	-118.28616	Plan check for power and energy. Change of use from Hospital to 132-unit Eldercare Facility(Assisted living) and a medical clinic. Scope includes reusing existing electrical equipment, adding new panelboards, and adding new distribution boards.  Total area: 57,912 sq ftB#17014-10000-05214	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45925	17041-10000-30504	7336 N BELLAIRE AVE	91605	2	186B161   528	2324002028	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.2047	-118.40929	Plan check for Title 24 only in existing space. Replace existing fixtures with LED fixtures. Total area: 5,600 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45926	18041-10000-09476	1360 S FIGUEROA ST # E	90015	14	126A205    86	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.03896	-118.26891	PC FOR ENERGY ONLY FOR T-24 CHANGE OF USE FROM RETAIL TO NAIL SALON TENANT IMPROVEMENT. SCOPE INCLUDES NEW CIRCUITS LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 2126 SQ.FT FOR LOW RISE BUILDING B#18016-10000-06993	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45927	15041-20000-32807	8520 W VENICE BLVD	90034	10	123B173   453	5065007021	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	ADDRESS	34.03435	-118.37888	Plan check for Title 24 only. Project site is an existing commercial, 2-story building. Project scope is a tenant improvement. Total lighting area = 7,115 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45928	18041-10000-08617	8960 N ETON AVE	91304	3	195B105    71	2779017042	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.23312	-118.59396	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45929	18041-20000-00924	2440 S STONER AVE	90064	11	123B149   906	4260031016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Issued	05/21/2019 12:00:00 AM	ADDRESS	34.03026	-118.44578	PV1.  Installation of 4.5 kW roof mounted grid tied PV system. (14) modules total, only (6) of which are new and installed on (N) trellis addition, and 4000W rated string inverter.  Interconnection to 400A 240/120V 1ph-3w service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45930	18041-10001-37062	9850 S LAUREL ST	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	01/26/2024 12:00:00 AM	ADDRESS	33.94793	-118.23082	CHANGE TO AN APPROVED SET. CHANGE UNDER DELTA 2. CHANGE INCLUDES ADDING 2-70A COMBI OVENS , 1-50A BALLER AND UPDATING THE LOAD CALCULATIONS. BLD PERMIT: 18010-10000-00187	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45931	15041-20002-42329	14832 W HESBY ST	91403	4	171A149   243	2263030031	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2016 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.162	-118.45636	Revisions to approved set of plans.  Change of backfeed breaker rating and AC wiring details.  Note: Fees $0 due to SB 1222(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.0KWac/13.407KWdc.(41) MODULE-SUNPOWER SPR-327NE-WHT-D(2)INVERTER-SUNNYBOY SMA SB6000TL-US AND SMA SB70000TL-US)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45932	16041-20000-06275	20345 W ARMINTA ST	91306	3	189B113   852	2107010024	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	PIN	34.21338085	-118.57695569	Install a roof-mounted solar array on a SFD. Existing solar array on roof, connecting new array and existing array to a 125A load center. Interconnecting with a 200A MSP.System size: 3kW (new) + 3.8kW (existing). Ungrounded system.(14) new 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45933	17041-20000-32363	13717 N DEANE LANE	91344	7	228B149   102	2502022036	RD3-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM				PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45934	17041-20001-32818	7348 N ETHEL AVE Units A&B	91605	2	186B161   541	2327015007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	06/01/2018 12:00:00 AM	PIN	34.20432132	-118.41768776	Supplemental for changes to approved set of plans under delta 1 only - changes include upsizing 2 transformers from 45kva to 75kva, and modifying lighting layout (T24 complies) layouts affected are single line diagram and lighting plan original scopePlan check for power and energy. Project site is a new commercial building. Project scope is a first time tenant. Total lighting area = 2,208 sq. ft.Note: Building application has been generated under 16014-20000-04290	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45935	18041-20000-18406	1076 W 30TH ST	90007	9	121-5A201 140	5039019046	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			05/17/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	34.02731	-118.28605	Remodel of (E) two-story apartment building.  Plan check for Title 24 Part 6 for common area corridors.  Renovation work in dwelling units included in scope of permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45936	19041-20000-44362	8635 W 3RD ST 10th Floor	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	05/14/2021 12:00:00 AM		Issued	05/14/2021 12:00:00 AM	ADDRESS	34.07373	-118.38073	Distribution, power, and lighting for healthcare facility.  Plan check for power and energy.Building permit under 19016-10000-34552.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45937	15041-20001-40198	6260 N TOPANGA CANYON BLVD Parking	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.18497	-118.60418	*****VOID*****Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size 532 kWac and consists of (19) inverters, (5) load center, and (2166) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.Note: Building plans have been submitted under 15016-20000-26338	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45938	15041-10000-17438	8500 W BEVERLY BLVD Space #691	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a retail (Footlocker) T.I located in Beverly Center. Scope includes new lighting, equipment, and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45939	16041-10000-26944	4647 N LAUREL CANYON BLVD	91607	2	168B165   772	2356037041	[Q]C2-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.15539	-118.39669	PC FOR ENERGY ONLY. REMOVE (OUTDOOR) HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA  11340 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45940	12041-10000-21770	19436 W VENTURA BLVD	91356	3	174B117   331	2163002016	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.17256	-118.55704	TENANT IMPROVEMENT ON EXISTING BANK, REMOVE AND NEW INTERIOR NON-BEARING PARTITIONS, RE-WORK SUSPENDED CEILING, RELOCATE MILLWORK AND FINISHES.FULL PLAN WAS REQUIRED BY APPLICANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45941	10041-20000-22343	19821 W NORDHOFF PL	91311	12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.23686	-118.56502	Plan check T24 Energy general/emergency lighting for commercial TI. Existing ckts. Permit for new lighting on existing ckts and misc permit for low voltage (tel. outlets)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45942	12041-20000-05967	13313 N CANYON RIDGE LANE PV-1	91344	12	225B133    68	2601016031	RS-1, RS-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	03/23/2012 12:00:00 AM	ADDRESS	34.31293	-118.50492	Roof mounted 3.45KW PV system with microinverter for single family.Note: Some PV devices permitted under 12041-40000-01600.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45943	18041-20000-00197	17217 W LORNE ST	91406	6	189B133   152	2204006021	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.21733	-118.50821	INSTALLATION OF AN 13.5kWH ENERGY STORAGE DEVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45944	14041-20000-09876	812 S GRAND AVE	90014	14	127-5A209  24	5144019025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM			PC Info Complete	05/28/2014 12:00:00 AM	PIN	34.04527178	-118.25793792	New parking structure on (E) parking lot.  600A service.  Power and energy.  Costs to be reverified - applicant submitted a revised set prior to assignment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45945	17041-10000-11033	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.06191	-118.41691	PC FOR ENERGY. T.I. COMMERCIAL. CONNECTED LOAD < 400A, TOTAL AREA 12516 SQ FT.B # 17016-10000-05290	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45946	13041-10000-22844	300 S FALCON ST BERTH 167-169	90744	15	024B205    40	7440019001	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	33.75794	-118.26677	Plan check new gasoline transfer pump (MI-13 motor upgrade) for Shell pump and storage facility on berths 167, 168, and 169 on Mormon Island.  New 400 HP motor and space heaters (and no other equipment).  Facility is adjacent to 300 S. Falcon St.  Hazardous classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45947	14041-20000-32953	1327 S SANTEE ST	90015	14	124-5A209 217	5133017013	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.03454	-118.25903	PC FOR POWER AND ENERGY. NEW CONSTRUCTION. NEW 600A SERVICE. 3 UNIT RETAIL SPACE. BUILDING TO BE SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45948	10041-20000-17661	1880 CENTURY PARK EAST	90067	5	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	02/01/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	Plan check T-24 Energy for TI of existing space (suite #100) in a high rise building. Existing emergency lighting and exit signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45949	17041-10000-46002	600 S SAMPSON WAY	90731	15	015B201    20	7440026***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	33.7387	-118.27907	Remove existing track-mounted light fixtures and install similar track lighting fixtures new in their place. These track lighting fixtures are for wall display. There is no changes to other lighting systemsPLAN CHK IS FOR TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45950	10041-20000-11777	13227 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM			PC Info Complete	08/09/2010 12:00:00 AM	ADDRESS	34.31115	-118.42909	Plan check power and energy for new 800Amp electrical system for 99 Cent Only store. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45951	15041-10000-39755	3435 W WILSHIRE BLVD	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.06194	-118.29866	PC FOR FA SYSTEM. NEW PANEL. RECONNECT EXISTING DEVICES. REPLACING FA PANEL AND 4 CONTROL PANELS.  LIKE FOR LIKE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45952	19041-20000-48946	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.23162	-118.58832	Replacment of medium voltage circuit breakers in (E) switchgear.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45953	10041-10000-05864	1605 N GLENDALE BLVD	90026	13	142-5A209 200	5423009026	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM			PC Info Complete	06/30/2011 12:00:00 AM	ADDRESS	34.08393	-118.26031	Raze and rebuild Arco convenience store, canopy, UST'S and adjacent pavement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45954	19041-30000-07350	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	04/28/2020 12:00:00 AM		Permit Finaled	01/20/2021 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for power only. Project scope is the installation of new distribution equipment to feed new cooling systems and re-feed existing motor loads, as indicated on SLD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45955	13041-20000-34489	5900 W WILSHIRE BLVD #2050	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.06237	-118.35809	Change to lighting in an existing high-rise office building.  Load for this specific phase is less than 400 amps.  Plan check only for Energy.  {{THE ENGINEER HAS BROKEN THE WORK DOWN INTO SMALL PHASES - FULL PLAN CHECK MAY BE REQUIRED FOR THE FULL SCOPE OF WORK IN THE BUILDING SUBJECT TO FIELD INSPECTOR REQUEST}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45956	19041-10000-46433	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	05/04/2020 12:00:00 AM	ADDRESS	33.9867	-118.44159	PC FOR ENERGY ONLY, TOTAL AREA IS 51,498 SQFT. SCOPE OF WORK IS RETROFITTING EXISTING LIGHTS TO LEDS, ALL EXTERIOR LIGHTING AND INTERIOS GARAGE LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45957	19041-10000-53668	1116 N MAYBROOK DR	90210	5	144B157   266	4358014018	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	06/08/2020 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	34.09102	-118.42942	[EPLAN] NEW PV1 ROOF MOUNTED INSTALLATION WITH SYSTEM SIZE OF 14.04KW DC/ 11.16KW AC, 39 MODULES (360R-PD), 39 POWER OPTIMIZERS (P400), 1 CENTRAL INVERTER (SE11400H-US), 2 SUBPANELS (0-200A), 1 ESS (TESLA POWERWALL) AND A NEW 225A MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45958	19041-20000-14430	700 S FLOWER ST Ste 2300	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	Commercial office TI in (E) highrise building.  Plan check for energy.  2815 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45959	14041-10000-02842	5450 W PICO BLVD STE#104	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.04862	-118.35714	T24 PART 6 ENERGY FOR 685 SQ FT MAKE-UP STUDIO. SCOPE OF WORK LIMITED TO 6 CKTS FOR LIGHTS AND RECEPTABLES ON (E) PANEL #104.  NEW CONNECTED LOAD < 400A. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.NOTE: INVESTIGATION FEE NEEDS TO BE CLEARED BEFORE PERMIT CAN BE PULLED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45960	09041-20003-24367	3327 E SABINA ST Bldg B	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			08/09/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 3 & Delta 4 Revision to approved plans for New Apartment Complex w/ multiple buildings (Bldg B) 2 of 2 Building. Includes additional ckts added for sign lighting and handicap lift.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45961	16041-10000-09980	11018 N SWEETWATER CT	91311	12	210B117    97	2708009015	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	EXEMPT	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.27025	-118.56344	PV1, NEW ROOF MOUNTED SOLAR SYSTEM 5kW AC AND A PV SUPERVISOR METER. (20) MODULES, SPR-X20-250-BLK.  (1) SB5000TL-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45962	19041-10000-42206	12600 W HART ST	91605	2	183B161   559	2324024001	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.19746	-118.40759	NEW ROOF-MOUNTED PV1 INSTALLATION OF 13 MODULES AND 1 CENTRAL INVERTERSYSTEM SIZE: 4.225 KW DC; 3.8KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45963	14041-10000-25478	2721 N JALMIA DR	90046	4	153B177    19	5571001024	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.1194	-118.36027	Standard Plan PV1 roof-mounted system including (1) combiner box,  (1) 6KW inverter, (26) Kyocera KD255 modules and power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45964	18041-10000-07944	17900 W CHATSWORTH ST	91344	12	207B129   441	2731008022	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.26468	-118.52395	"Plan check for T-24 ONly, ""Energy Reduction Project"" for Chase Bank. Replace indoor and outdoor luminares to LED fixtures using existing circuits. Total affected area is 19189 Sq. Ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45965	16041-10001-15022	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM			PC Approved	09/27/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA DCN-001 AND CLOUDED ON PLANS. CHANGES INCLUDE REVISED FLOOR PLAN AND LIGHTING PLAN. MINOR CHANGE IN EQUIPMENT LOADS. NO OTHER CHANGES. PROVIDED UPDATED PLANS AND T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45966	16041-30000-36016	338 N MARIPOSA AVE	90004	13	138B197    94	5520024009	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Apartment			10/11/2016 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/12/2021 12:00:00 AM	ADDRESS	34.07745	-118.29927	Plan check for power and Title 24.  New 4 story 14 unit apartment building.  New 1,000 amp service @ 120/240 single phase.  Total common area = 11,276 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45967	17041-10000-31236	11479 W OXNARD ST	91606	2	177B169   773	2338002014	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.17956	-118.38183	PC for T24 only for removal of outdoor HID fixtures and replace with new LEDfixtures. Total of 3700sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45968	11041-10000-12440	811 W WILSHIRE BLVD Ste #2050	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.04973	-118.2584	T.I. for Suite # 2050.  Replacing light fixtures.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45969	16041-20002-38389	11319 N LOUISE AVE	91344	12	210B133    46	2711005008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	34.27616	-118.51121	"[[[changes to approved set. adding performance meter to the single line diagram. delta 1 changes only]]]""$0 permit fees due to senate bill 1222 ""Plan check for a PV1 roof-mounted PV system. System size is 12.5 kWac and consists of (50) modules, (50) micro-inverters, and (1) load center."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45970	17041-30000-19899	11906 W SAN VICENTE BLVD Basement	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM			PC Approved	06/13/2017 12:00:00 AM	ADDRESS	34.05239	-118.47055	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from retail to health club. Total lighting area = 255 sq. ft.Note: Building application has been generated under 17016-10000-13827	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45971	16041-20000-21191	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI TO AN EXISTING COMMERCIAL BUILDING(HIGH RISE).  CHANGING EXISTING FLUORESCENT LIGHTING TO NEW LED LIGHTING NEW CONTROLS TO EXISTING PANELS USING EXISTING CIRCUITS.  EMERGENCY LIGHTING EXISTING TO REMAIN.  TOTAL SQUARE FOOTAGE 3701.  SCOPE OF WORK TO BE PERFORMED IN SUITE 2060.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45972	13041-20000-10610	14006 W RIVERSIDE DR 260	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM			PC Approved	04/24/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	add chandelier to approved title 24 only under permit # 130411000004663	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45973	18041-10000-44616	5870 W JEFFERSON BLVD SUITE E	90016	10	120B173   383	4205027010	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM			PC Approved	11/21/2018 12:00:00 AM	ADDRESS	34.02285	-118.37583	NEW POWER CIRCUITS AND LIGHTING IN EXISTING OFFIC ESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45974	11041-20000-10819	14724 W VENTURA BLVD 2nd Floor	91403	5	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	07/27/2011 12:00:00 AM	ADDRESS	34.15162	-118.45395	T.I. to existing high rise building.  Install general/emergency lighting in partial of 2nd floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45975	18041-10000-26208	18050 W VANOWEN ST	91335	3	180B125    48	2122028013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM			PC Info Complete	01/30/2019 12:00:00 AM	ADDRESS	34.19372	-118.52686	PC FOR POWR AND ENERGY FOR change of use from church to early learning center. OCC. LOAD >100 SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS.TOTAL AFFECTED AREA 8851 SQ.FTB#18014-30000-03828	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45976	16041-10000-41314	543 S WESTERN AVE	90020	4	135B193   818	5503018019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.06407	-118.30938	TI TO EXISTING RESTAURANT. NO CHANGE IN USE OR OCCUPANT LOADS. UPGRADING TO NEWER CONDITION. PROVIDING NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45977	19041-20000-49759	6433 N FALLBROOK AVE	91307	12	180B097   434	2038040031	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.18751	-118.62365	Power and lighting for tenant improvement to (E) shopping center.  New fitting rooms and display cases. Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45978	14041-20000-07223	11915 N LAUGHTON WAY	91326	12	216B125    96	2870023006	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.29002	-118.53501	PV1 MICROINVERTER NONSTANDARD PLAN. TOTAL SYSTEM SIZE 6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45979	17041-20000-09746	515 S FLOWER ST 11th flr	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	ti to an existing commercial building.  adding new lighitng new controls to new panels.  newly conncted load < 400amps.  plan check for energy only.  total quare footage 12409 in the 11th flor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45980	19041-10000-37433	1618 W 23RD ST	90007	8	123B197   339	5054002008	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.03531	-118.298	NEW 3.72KW ROOF MOUNTED PV SYSTEM WITH 12 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45981	18041-20000-04742	5259 E ALDAMA ST	90042	1	153A225   247	5469024016	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.11348	-118.20229	Plan check for power only. Project scope is the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45982	19041-20000-11526	14626 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.22128	-118.45073	Plan check for new fire alarm system, fire alrm devices: 25 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45983	16041-20000-26609	11000 W PEORIA ST	91352	7	201B173   351	2538013005	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.24555	-118.3705	Plan check for PV roof mounted system. System size: 6.08kW with 19  AC Modules. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45984	18041-20000-43755	20810 W SPRUCE CIR #69	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.29502	-118.5875	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45985	19041-20000-34615	16827 W BIRCHER ST PV 1	91344	12	213B133   333	2610008003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.28181	-118.49901	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.96 KW DC/4.498 KW AC. SCOPE OF WORK CONSISTS OF (16) PV MODULES WITH POWER OPTIMIZERS AND A 7600W CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45986	14041-20000-27123	6642 N ORION AVE	91406	6	180B145   242	2234019014	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	10/25/2014 12:00:00 AM	ADDRESS	34.19162	-118.47036	install roof mounted pv system sized 6.0kw interconnected with msp.(30) trina solar tsm-255 modules(30) power optimizers p300(1) solar edge 6000 inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45987	17041-10000-38015	1901 S AVENUE OF THE STARS # 1005 & 1-010	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.05949	-118.41705	Alterations in existing office space-new luminaires using existing branch circuitsPLAB CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45988	15041-20000-10035	12452 W OSPREY LANE #1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	Installation of new roof mounted solar PV array on 3 unit apartment building (triplex).  Each unit panel is fed by a seperate inverter (3 inverters total).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
45989	15041-10001-31734	100 WORLD WAY TERMINAL 1-LV 1-ROOF	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	delta 3 revisions. change to devices on level 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45990	17041-10000-25057	19050 W SHERMAN WAY	91335	3	183B121   158	2129034017	RD1.5-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.20091	-118.5488	Plan check for title 24 only in existing space outdoor, replace existing fixtues with LED fixtures.Total area: 10,950 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45991	17041-10001-31587	2337 N HIGH OAK DR	90068	4	153B193   292	5587003021	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.11299	-118.31207	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED. CHANGES INCLUDE REVISING CONDUCTORS CONDUCTOR SIZES DUE TO VOLTAGE DROP, TRENCHING AT INVERTER OUTPUT CONDUCTORS, AND REVISING ROOF-TOP PLAN. NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-31587	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45992	18041-10000-26197	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM			Verifications in Progress	08/02/2018 12:00:00 AM	ADDRESS	33.97902	-118.43558	REPLACING AN OLD AND DAMAGED 1600 AMP, 277/480V SERVICE EQUIPMENT WITH A NEW ONE LIKE TO LIKE AT THE SAME LOCATION. RECONNECT TO EXISTING LOADS. NO NEW LOAD ADDED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
45993	18041-10000-46051	355 S GRAND AVE 3100	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM			PC Info Complete	12/04/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR T24 ONLY, INTERIOR OFFICE TI, NEW CONNECTED POWER < 200A , AND ARE FED FROM EXISTING PANEL BOARD. TOTAL AREA: 3400 SQ.FT   (B# 18016-10000-38854)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45994	13041-10003-34186	100 S SANTA FE AVE ste #1000	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM			PC Approved	11/03/2014 12:00:00 AM	ADDRESS	34.04798	-118.23239	Plan check for power and energy. 1st time tenant. TI for  Metrolink office. 6 story mixed use - not high rise. Located in methane zone.(((((( changes made to previously approved set.  8-15-2014 m.z ))))))))panel A1 sub fed from  panel A, 1 ckt added. 9-04-14 mz((((((((   109-2014  m.z  CHANGES INCLUDE ADDITION OF 6 NON DEWLING POWER EQUIPMENT AND SOME SPARES.))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45995	10041-20000-17644	11551 W SANTA MONICA BLVD	90025	11	126B149    80	4261001018	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	01/14/2011 12:00:00 AM	ADDRESS	34.04521	-118.45332	Plan check power and energy for first tenant (Sangaki Bakery).  Install new  panel, branch circuits and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45996	18041-20000-23593	26339 S PINES ESTATES DR	90710	15	033B193   960	7411021***	(Q)RD6-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	33.78243	-118.30105	PV1.  Install 7.584 kW AC roof mounted grid tied PV system.  (25) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
45997	12041-10000-30061	19845 W DINA PL	91311	12	204B113    98	2708026018	RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.2582	-118.56536	PV1:  9.36 KW DC roof mounted PV system for a single family residence.  Applicant is using the standard plan.  Installing 39 modules, 1 combiner box, 1 inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
45998	10041-20002-23778	7800 W WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	PIN	33.93790872	-118.42837934	Revision to the approved plan. Install a new staker control panel. Privously was checked for: ((((((((((((((((move staker location plan check only))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
45999	12041-10000-18790	445 S FIGUEROA ST 32nd Floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Approved	08/09/2012 12:00:00 AM	ADDRESS	34.05295	-118.25675	T.I. to an existing office space on the 32nd floor of an existing high-rise.  Change to lighting.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46000	12041-10000-16166	642 S ALVARADO ST	90057	1	133-5A203 196	5141001035	C4-2	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.05819	-118.2755	T.I. to an existing restaurant, load is less than 400A and occupancy load is less than 99.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46001	18041-10000-44567	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM			Reviewed by Supervisor	12/06/2018 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR NEW FIRE ALARM SYSTEM IN COMMERCIAL BUILDING186 FA DEVICES, 1 FA PANEL, 1 COMM PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46002	12041-10000-21551	13755 N GAVINA AVE	91342	7	228B161   330	2582029034	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.32222	-118.40711	PLAN CHECK NEW ROOF MOUNTED 1.4KW PHOTOVOLTAIC SYSTEM ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46003	16041-10000-33463	345 N SAINT PIERRE ROAD	90077	5	141B153    80	4362022016	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	ADDRESS	34.0848	-118.43678	(This is plan check only, permit is covered under combo - Building permit # 16016-10000-07410) PC FOR POWER ONLY FOR AN EXISTING SINGLE FAMILY HOME. SCOPE INCLUDES A NEW 600A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46004	15041-10000-03420	901 S WESTERN AVE	90019	4	132B193   885	5093001036	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2126.20	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM			PC Approved	02/04/2015 12:00:00 AM	PIN	34.05565533	-118.30942786	Energy plan check for an extention of commercial building (sauna)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46005	11041-10000-20348	8930 N VILLAGE AVE	91352	2	195B177   265	2404001006	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley	YES	1021.01, 1021.02	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	10/20/2011 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.23076	-118.35614	First time occupancy. Existing Service, New Panels & Circuits, Plan Check is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46006	12041-10000-27602	2750 E 1ST ST	90033	14	126A225     5	5180014011	QC4-1	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			Ready to Issue	11/15/2012 12:00:00 AM	ADDRESS	34.04146	-118.20521	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. INTERIOR REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46007	19041-20001-18706	20500 W BIRMINGHAM WAY	91326	12	213B109   807	2701097001	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.28293	-118.581	Reapproval of lost set of plans.$0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46008	18041-10001-26575	7270 WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			Reviewed by Supervisor	07/31/2018 12:00:00 AM	ADDRESS	33.94145	-118.42037	FEE EXPEDITE PLAN CHECH FOR 50KVA SYSTEM ROOF MOUNTED PV CONSISTING OF 1 CENTRAL INVERTER(TRIO 50.0-TLOUTD-US) WITH 10 STRINGS AT 14MODULES A TRING = 140 MODULES(SOLARWORLD SW350)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46009	14041-10000-32918	754 S AVENUE 60	90042	14	150A233   222	5312013005	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	2013.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.10418	-118.17923	Installation of new roof mounted solar PV array.  Total system size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46010	17041-20000-45932	16911 W ROSCOE BLVD	91325	12	192B133   234	2205001004	M2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Issued	12/21/2017 12:00:00 AM	ADDRESS	34.22138	-118.50141	New addition at front of (E) 1-story animal hospital.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46011	18041-10000-31418	715-717 N VIRGIL AVE	90029	13	141B197   436	5539020030	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Issued	08/20/2018 12:00:00 AM	ADDRESS	34.08407	-118.28701	plan chech for title 24 only - CHANGE OF USE PORTION FROM RETAIL TO BAKERY/CAFE.  Scope include new lights and receptacles.  total affected area = 1794 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46012	17041-10000-02286	9016 N SEPULVEDA BLVD	91343	7	195B145   655	2654004053	R3-1, [Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.23418	-118.46647	Plan check for Titel 24 only in existing retial space T.I. Total area; 5,570 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46013	19041-10000-07929	2511 S SAN PEDRO ST	90011	9	120A207   269	5127010011	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	34.02234	-118.26105	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46014	18041-10000-15186	21040 W VICTORY BLVD	91367	3	180B105    53	2149003035	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.18814	-118.59248	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46015	19041-10000-05153	6600 N TOPANGA CANYON BLVD # 2088	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Energy plan check for a retial T.I; Scope includes new lighting and equipment with a total area of 884-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46016	14041-20000-21167	1351 E 22ND ST	90011	9	120A211   396	5119004900	OS-1XL	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	05/07/2016 12:00:00 AM	ADDRESS	34.02097	-118.25171	plan check for energy only on a renovation existing pool building. total 5876 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46017	15041-20000-28070	10100 W SANTA MONICA BLVD 7th Floor-Corridor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Approved	08/26/2015 12:00:00 AM	ADDRESS	34.06191	-118.41691	Title 24 plan check only.  Total area = 1,615 sq. ft.  Remodel of corridor and lobby on 7th floor of existing commercial highrise building.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46018	11041-10001-07654	2269 W WASHINGTON BLVD	90019	10	126B193   914	5073014010	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Apartment			02/07/2012 12:00:00 AM			PC Approved	02/07/2012 12:00:00 AM	PIN	34.04015612	-118.31130248	PLAN CHECK REVISION TO APPROVED PLANS. REVISION CLOUDED ON PLAN. CHANGES CONSIST OF OVERHEAD SERVICE ENTRANCE CONDUCTORS AND REDUCE HP PANEL OCPD/FEEDER SIZE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46019	13041-20000-06614	19560 W GIFFORD ST PV-1	91335	3	186B117  1046	2116004122	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.20501	-118.56002	PV-1. 9.555kW DC, 7.5kW Inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46020	14041-20000-06166	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			PC Info Complete	06/26/2014 12:00:00 AM	ADDRESS	34.04896	-118.25139	GENERATOR UPGRADE AND REFEEDING SOME DISTRIBUTION PANELS FOR EXISTING HIGHRISE OFFICE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46021	13041-20000-27375	14366 W BEAVER ST	91342	7	219B149   604	2507025005	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Expired	10/28/2015 12:00:00 AM	ADDRESS	34.29599	-118.44628	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.4 KW AC USING 30 MODULES. USING ENPHASE MICROINVERTER M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46022	16041-10001-00616	4839 N LOWELL AVE	91214	7	201B205   435	2571003025	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.24719	-118.26621	07/05/16PC FEES ARE $0 DUE TO SENATE BILL 1222.Changes to an approved set of plans. All changes are clouded under Delta A. Changes include adding an AC disconnect on the single line diagram and on the site plan/roof-layout. Note: Permit paid under PCIS#16041-10000-00616((((PV1, rooftop solar installation, 4.2 kW AC(20) KU2656ZPA(1) PVI-4.2-OUTD-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46023	17041-10001-04624	20165 W RINALDI ST BLDG S1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.27527	-118.57297	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 3. CHANGES INCLUDE ADDING SITE LIGHTING, REPLACING EXTERIOR LIGHTS,  REVISING TITLE 24 CALCULATIONS, AND REVISING PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46024	13041-10000-24097	2920-2930 W ROWENA AVE BUILDING 2	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.10823	-118.26884	NEW BUILDING. APARTMENT.  1 OF 6 TOTAL UNITS. BUILDING 2. NEW 400 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46025	14041-20001-10974	10331 N BEVIS AVE	91345	7	204B149   152	2648008028	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.25845	-118.4555	EXPEDITE PER CUSTOMER REQUESTPV1 INSTALL ROOF MOUNTED PV SYSTEM WITH POWERBOX OPTIMIZERS SIZED 7.5KW INTERCONNECTED WITH MAIN PANEL.  (2) SOLAREDGE TRANSFORMERLESS INVERTERS 3.8KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46026	13041-10000-05171	101 S THE GROVE DR	90036	4	138B177  1131	5512003038	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			Corrections Issued	02/28/2013 12:00:00 AM	ADDRESS	34.07256	-118.35874	TI OF SERVICE HALLWAY. USE OF SPACE FOR ATM TRANSACTIONS. TOTAL AREA 102 SQ FT. PART OF MALL. PC FOR T24 ONLY. PERMIT FOR INSTALLATION ALREADY ISSUED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46027	14041-10001-23471	21860 W BURBANK BLVD BLDG B	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			PC Approved	10/30/2014 12:00:00 AM	ADDRESS	34.17198	-118.60379	EXPEDITED PER APPLICANTS REQUEST.PHASE 2: : PV2 ROOF MOUNTED SOLAR SYSTEM. NEGATIVELES GROUNDED. NO NEW INVERTERS. TIED BACK INTO THE OLD SYSTEM.(60) YINGLI YL MODULESPHASE 1: 13041-10000- 29243 photo voltaic roof top for a 3 story bldg,768 modules, 3 combiner boxes, 2 inverters, Roof mounted , flat roof. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46028	12041-10000-05502	800 W 1ST ST	90012	9	132A211    33	5151027257	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Apartment			03/09/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.05698	-118.25121	REPLACE AN EXISTING OLD EMERGENCY GENERATOR (ON THE ROOF OF A HI RISE RESIDENTIAL) WITH A NEW 150KW GENERATOR IN AN OPEN COORIDOR AREA OUTSIDE THE BUILDING.  INSTALL A NEW TRANSFER SWITCH CONNECT TO EXISTING EMERGENCY PANEL ON THE ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46029	17041-10000-36228	944 E PICO BLVD # 5	90021	14	123A211   265	5132018034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	11/08/2017 12:00:00 AM	ADDRESS	34.03051	-118.24925	INTERIOR ALTERATIONREPLACE HID LUMINAIRES WITH LED      TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46030	19041-10000-52971	6643 W FOOTHILL BLVD	91042	7	201A203    11	2570018004	C2-1VL, R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.20	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.24688	-118.27677	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46031	09041-10001-22194	1149 S HILL ST	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM			PC Approved	05/25/2010 12:00:00 AM	ADDRESS	34.03926	-118.26099	Delta C revisions- revised permitted set of plns to indicate as-built conditions	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46032	13041-10000-20821	9-11 E DUDLEY AVE	90291	11	109-5A141 122	4286030012	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			Corrections Issued	08/05/2013 12:00:00 AM	ADDRESS	33.99418	-118.47975	Combine existing electrical service, install subpanels for new market cafe.  Newly connected load less than 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46033	18041-20000-38198	10939 N WILLOWBRAE AVE	91311	12	210B105   168	2722037011	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.26918	-118.59868	Plan check for a PV1 roof-mounted PV system. System size is 14 kWdc/11.5 kWac and consists of (40) modules, (21) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46034	13041-20000-31799	15955 W ARMINTA ST	91406	6	189B141   107	2206007020	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.21399	-118.48108	PC FOR POWER ONLY. NEW 800 AMP SERVICE WITH SUBPANELS.  NO LOADS ON PANELS, FUTURE WORK MAY REQUIRE FULL PLAN REVIEW SUBJECT TO FIELD INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46035	18041-10000-29746	5414 S CRENSHAW BLVD	90043	8	108B185   401	5006008026	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.99262	-118.33045	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 241 FA DEVICES, AND 5 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46036	15041-20001-23744	6050 1/2 N COLFAX AVE	91606	2	177B169   657	2334014041	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Apartment			07/24/2015 12:00:00 AM			PC Approved	08/12/2015 12:00:00 AM	ADDRESS	34.18082	-118.38766	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (9) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46037	13041-20000-10753	17100 W VENTURA BLVD	91316	5	168B133    80	2289005012	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			Corrections Issued 2	04/25/2013 12:00:00 AM	ADDRESS	34.16003	-118.50552	energy plan check classroom remodel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46038	15041-20000-16713	479-483 W WASHINGTON BLVD	90291	11	105A147   115	4227023027	(Q)C4-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	PIN	33.98252292	-118.46170822	Plan check for methane zone requirements only. Projet site is (6) existing buildings (apartments).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46039	15041-20000-43455	3104 N GLENDALE BLVD	90039	13	154-5A207 404	5437008025	[Q]C4-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.11624	-118.26231	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (PILATES STUDIO/GYM). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1364 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46040	14041-10000-00973	8900 S SEPULVEDA BLVD	90045	11	096B165  1026	4123001031	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM			PC Info Complete	03/19/2014 12:00:00 AM	ADDRESS	33.95574	-118.39596	pc for power and energy. (e) office depot cutting space in half with demising wall. methane buffer zone. new service. building application #14016 10000 00587. DEMISING OF AN EXISTING OFFICE DEPOT STORE FOR A NEW ADJACENT TENANT; NEW FINISHES, NEW MILL WORK AND NEW LAYOUT (grey circuits counted as existing)NO: 77706  -- ElectricalDo not Issue electrical, mechanical and building permits for theerection, construction, addition to, or exterior structuralalterations of any building or structure, including, but notlimited to signage including, pole signs and/or monument signslocated in the Community Design Overlay District, prior toobtaining written clearance from the City Planning Department. APlanning clearance is not required for (1) interior alterations,(2) demolitions, or (3) a residential building on a parcel or lotwhich is developed entirely as a residential use and consists ofone or fewer dwelling units. Follow the instructions given inZoning Information File No. 2388, effective 7/1/08.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46041	09041-10008-24366	3327 E SABINA ST Bldg A	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			12/20/2011 12:00:00 AM			PC Approved	12/20/2011 12:00:00 AM	ADDRESS	34.0306	-118.20046	FINAL CHANGES TO PERMITTED SET OF PLANS; SEE ATTACHED SHEETS LISTING THE SHEET DESIG NATION AND THE CHANGES -DELTA 6. New Apartment Complex w/ multiple buildings (Bldg A) 1of 2 Building.  4 typical units, 64 units total.  Permit is for service, distribution, new ckts, busway, panels.  P/C is for Power and energy.   Modification to seperate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46042	16041-10008-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM			PC Approved	04/11/2018 12:00:00 AM	ADDRESS	34.04771	-118.46271	Changes to an approved set of plans, note changes under delta 17 & A14, clouded areas. Changes include the addition of receptacles, addition of outdoor lighting and revision of indoor power supplies in the conference room.Note: Permit Fees are paid under PCIS#16041-10000-40191	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46043	11041-10000-27144	18711 W TULSA ST	91326	12	207B121    24	2717016022	RE11-1	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.26773	-118.53986	Plan check 5.64KW roof mounted photovoltaic system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46044	18041-10000-08982	2501 W JAMES M. WOOD BLVD	90006	1	132A201   219	5141025026	C2-1	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM			Reviewed by Supervisor	03/30/2018 12:00:00 AM	ADDRESS	34.05547	-118.28307	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK INCLUDES NEW LIGHTING ONLY TYING TO EXISTING CIRCUITS IN AN AUTOBODY SHOP WITH AN EXISTING SPRAY BOOTH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46045	17041-10001-43273	15553 W AQUA VERDE DR	90077	5	156B141    89	4378032009	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.12218	-118.4735	Supplemental PC for changes to approved set. Relocating roofmounted module layout and string configuration.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46046	12041-10000-11329	840 S SPRING ST	90014	14	127-5A209 228	5144016048	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM			PC Info Complete	05/16/2012 12:00:00 AM	ADDRESS	34.04233	-118.25416	Title 24 and energy, emergency lighting, two story, ground and secon flor restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46047	10041-20000-04361	1200 W 7TH ST	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM			PC Info Complete	03/10/2010 12:00:00 AM	ADDRESS	34.05136	-118.26616	ENERGY PLAN CHECK 7TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46048	19041-20000-36883	24550 W STONEGATE DR	91304	12	186B089   298	2017030024	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Issued	09/16/2019 12:00:00 AM	ADDRESS	34.20736	-118.6571	PV1. INSTALL 11.34 KW DC ROOFMOUNTED SOLAR SYSTEM WITH (36) MODULES AND OPTIMIZERS AND (1) INVERTER (SE10000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46049	19041-10000-44334	610 E CALIFORNIA AVE	90291	11	108B145  1157	4241005900	PF	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	33.9913	-118.46545	T-24 PLAN CHECK FOR A TI. SCOPE OF WORK INCLUDES NEW EQUIPMENT, LIGHTING , RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 7656 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46050	15041-10000-28672	1515 N CAHUENGA BLVD	90028	13	147A187   114	5546013015	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.09851	-118.32972	TI ON EXISTING COMMERICAL (RETAIL) BUILDING. PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTING. TOTAL AREA 1652 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46051	15041-10000-14405	6115 W SUNSET BLVD # 130-140	90028	13	147A189    24	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.09819	-118.32261	PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT FIRST TIME TENANT ON EXISTING 1200 AMP SWITCHBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46052	15041-20000-31675	8425 N BURNET AVE #6	91343	6	192B145   290	2654025***	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.22352	-118.46359	PV1 SFD PC FOR 5KW AC USING SINGLE INVERTER SOLAR EDGE WITH POWER OPTIMIZERS. TOTAL OF 17 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46053	13041-10000-05518	1600 N WESTERN AVE	90027	13	148-5A193 288	5544022003	[Q]R5-2	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			03/04/2013 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.10004	-118.30899	CRA CLEARANCE REQUIRED. New fire alarm system for a new 4-story apartment building.  1 fire alarm control panel and annunciator and > 250 devices installed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46054	10041-20000-23159	12424 W WILSHIRE BLVD	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Public Safety Only			11/18/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.04135	-118.47058	Plan check for fire alarm system replacement and upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46055	19041-20001-31838	3740 W 58TH PL	90043	8	108B185  1081	4004008010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	33.98795	-118.3393	09-13-2019 Changes to an approved set of plan, Changes include relocat modules layout on roof,  all changes has been clouded as delta A. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46056	17041-10001-07737	7002 W CLINTON ST	90036	5	141B181   907	5525020011	RD1.5-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.08176	-118.34333	Change to an approved set by adding (2) ckts on the floor plan.(((new gym.  plan check for hazardous loaction (methane zone) and power and energy.  total square footage 4656.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46057	19041-20001-52449	11259 W OLYMPIC BLVD	90064	11	126B153   958	4260001028	[Q]C2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	11/19/2020 12:00:00 AM	ADDRESS	34.03875	-118.44075	Expedite per applicant request. Plan check for PV roof mounted system, PV system size: 120.08KW DC, 100KW AC with 304 PV Modules and 1 inverter(100KW) Supply  side connection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46058	13041-10001-35469	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	AT LAX TERM 2, INSTALL TEMPORARY FEEDER FROM 800A SECTION OF EXISTING DIST BD TO SUPPLY PERMANENT LOADS PERMITTED ON ORIGINAL APPLICATION THROUGH NEW 800A DIST SWITCH AND THROUGH 800A DIST BD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46059	19041-10000-07104	1016 S TIVERTON AVE 1-12	90024	5	132B153    68	4360002002	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM			PC Info Complete	04/08/2019 12:00:00 AM	ADDRESS	34.06153	-118.44282	PC FOR PWR, NEW SERVICE 600A, 120/240V, 3W. NEW SERVICE TO REFEED EXISTING 13 UNITS APTS AND HOUSE PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46060	17041-10000-04553	12300 W WILSHIRE BLVD UNIT 326	90025	1	130-5A207 637	5143019***	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.04245	-118.46922	Plan check for power and energy for dental office T.I. Total area; 1,348 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46061	18041-10000-13984	11233 N SAN FERNANDO ROAD	91331	7	210B157   166	2616030063	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.2739	-118.43067	T-24, pc for energy only. Replacing HID fixtures with new LED for indoor/outdoor use. Total affected area is 172775 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46062	17041-10000-02781	4947 E HUNTINGTON DR	90032	14	144A233   287	5306014051	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	PIN	34.0877517	-118.17572273	Plan check for Title 24 only in existing restaruant T.I. Total area: 2794 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46063	14041-10000-25830	1616 N FULLER AVE	90046	4	147B181   324	5548009040	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM			PC Approved	09/18/2014 12:00:00 AM	ADDRESS	34.1003	-118.34883	Title 24 plan check only.  Total area = 770 sq ft Fitness Center. Building application 14014-20000-00172. Building submitted before title 24 part 6 effective date.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46064	19041-20001-11091	654 N VIRGIL AVE	90004	13	142-5A201 290	5539026035	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.08334	-118.28667	Expedite per applicant request Plan check for PV roof mounted system, system size: 24.05KW DC, 20.68KW AC CEC with 65 PV Modules and 2 inverters(10.0KW) connected to 400A Service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46065	15041-20000-14171	6316 N TOPANGA CANYON BLVD 1115-B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for 1st time tenant for DAVIDsTEA Suite 1115-B. New interior reatil  alteration for tea retail store. Tenant work includes new light, electrical, HVAC and stroe front. Total area: 1490 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46066	19041-20000-45173	20536 W PLUMMER ST	91311	12	198B109    55	2748041003	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	02/15/2021 12:00:00 AM		Permit Finaled	01/16/2024 12:00:00 AM	ADDRESS	34.2425	-118.58118	"PLAN CHECK FOR POWER AND ENERGY ADD NEW PANELS AND EQUIPMENTS ON EXISTING SERVICE.NOTE:""CHANGE OF USE TO PLANT GROWING FACILITY"" AS INDICATED ON THE PLAN."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46067	19041-20000-03256	11337 W VENTURA BLVD	91604	2	162B173   409	2366036020	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.14039	-118.37721	TI to (E) commercial office space on first floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46068	16041-20000-13183	22960 W CALABASH ST	91364	3	168B097   150	2074026002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.15951	-118.62815	Plan check for an addition of a PV1 roof-mounted 3 kWac PV system onto an existing system. PV addition consists of (1) inverter, (10) modules, and (1) load center. Total system size is 9 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46069	16041-10000-26174	540 E ROSE AVE	90291	11	111B141   333	4240010008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	33.99852	-118.4729	PC FOR FIRST TIME TENANT. ICE CREAM SHOP. PC FOR POWER AND ENERGY. NEW KITCHEN EQUIPMENT AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46070	15041-10000-05688	11995 W BLUFF CREEK DR	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	New fire alarm system for building 5 (core/shell) . Work includes (1) fire alarm panel, and (16) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46071	13041-10000-36315	10210 N OAKDALE AVE CLASSROOM	91311	12	204B113   213	2726008001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.25596	-118.56656	PLAN CHECK FOR POWER AND ENERGY. CONSTRUCT NEW CLASSROOM BUILDING CONSISTING OF SIX (6) CLASSROOMS AND THREE (3) GROUP STUDY ROOMS.  1 OF 2. BUILDING PC # 13010-10000-04112	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46072	11041-10003-02953	1825 E 22ND ST	90058	14	118-5A215 107	5167006014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM			PC Info Complete	12/06/2012 12:00:00 AM	ADDRESS	34.01646	-118.23907	SUPPL. APPLICATION FOR REVISED SINGLE LINE TO SHOW CHANGES HOW PANELS B AND C ARE SUPPLIED .  REPLACE 3 TRANSFORMERS (112.5, 112.5 & 75 KVA) WITH ONE 150KVA TRANSFORMER.  NOTE: THE TRANSFORMER SHALL BE INSTALLED IN A FIRE RATED ROOM OR COMPLY WITH THE EXCEPTIONS OF SEC 450.21.  ADDITIONAL PERMIT MAY BE REQUIRED SUBJECT TO FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46073	17041-10000-07233	2250 E 111TH ST	90059	15	087A217   600	6067016049	[T][Q]R3-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.93453	-118.23238	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 14550 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46074	18041-10000-21490	2121 S AVENUE OF THE STARS #2310	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM			PC Info Complete	06/08/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	Energy plan for an office T.I located on the 23rd floor of a highrise buildig. Scope includes new lighting and equipment with a total Title-24 area cover 2871-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46075	12041-20000-12140	3323 S CLUB DR	90064	5	123B165   761	4316025013	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Expired	10/28/2014 12:00:00 AM	ADDRESS	34.03234	-118.40276	Photovoltaic system on roof of single family dwelling using enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46076	17041-10000-32008	20001 W PRAIRIE ST	91311	12	198B113   112	2761040018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.23929	-118.56833	PC FOR POWER ONLY. SCOPE INCLUDES ADDING A NEW 500KW STANDBY GENERATOR TO AN EXISTING ELECTRICAL SYSTEM. GENERATOR IS FOR A COMMERICAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46077	14041-20000-22859	11028 N CAYUGA AVE	91331	7	210B153   676	2616028001	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM			Corrections Issued	08/23/2014 12:00:00 AM	ADDRESS	34.27031	-118.43393	pv1 system 7.25 kw	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46078	17041-20000-33237	3560 S WATT WAY BASEMENT	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.02169	-118.28671	Renovation of (E) exercise rooms in physical education building basement.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46079	14041-20001-03426	24554 W INDIAN HILL LANE	91307	12	186B085    91	2031014037	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.20486	-118.65772	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING POWER OPTIMIZERS 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46080	11041-20000-01600	1565 S WESTERN AVE	90019	10	126B193   272	5073011028	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.01, 2213.02	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	09/19/2011 12:00:00 AM	PIN	34.0437836	-118.30937412	PLAN CHECK POWER AND ENERGY INTERIOR REMODELING TO EXISTING DENTAL CLINIC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46081	14041-10000-00952	726 N WESTERN AVE	90029	13	141B193   466	5535018028	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.08431	-118.30895	Tenant improvement in existing Waba restaurantplan chk is for title 24ALL WORK TO BE INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46082	19041-20000-13642	17538 W LORNE ST	91325	12	189B129   270	2201004010	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	PIN	34.21697139	-118.51571266	ROOFTOP INSTALLATION ON EXISTING SFD TO FEED DETACHED ADU. SYSTEM SIZE IS 2.17KW DC/1.68KW AC/1.93KW AC CEC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES 310W AND (7) ENPHASE IQ 6 MICROINVERTERS 240W.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46083	17041-10000-42599	5515 N FIGUEROA ST	90042	1	151-5A227 258	5468024008	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.10866	-118.19506	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46084	13041-10001-00873	650 S AVENUE 21	0	1	135A221    76	5410016002	M3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	PIN	34.06374638	-118.2175984	][] CHANGES MADE TO AN APPROVED SET OF PLANS; PER INSPECTOR REQUEST, CHANGES INCLUDES REVISION TO SINGLE LINE DIAGRAM AND TITLE 24 PART 6 ENERGY; PLAN CHECK FOR TITLE 24 ENERGY ONLY. PERMIT EXISTING UNDER 13041-10000-00873 AND 13041-20000-29708 ][][]PLAN CHECK FOR POWER AND ENERGY GYMNASIUM (PLACE OF ASSEMBLY ARTICLE 518).NOTE: EXISTING PERMIT UNDER 13041-20000-29708	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46085	13041-20000-01508	12196 W IREDELL ST	91604	2	159B165   166	2382014017	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.12983	-118.39923	Photovoltaic system on roof of single family dwelling using transformerless inverters. Two 3.8kW Inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46086	19041-20000-22244												Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46087	19041-30000-37679	1101 S PACIFIC AVE	90731	15	015B197  1289	7454019012	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Closed	10/18/2019 12:00:00 AM	ADDRESS	33.73402	-118.28809	energy plan check only for Change of use from bakery/market to bar wtih live entertainment including Dance floor. area of scope 2462sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46088	17041-20000-14154	625 S ST ANDREWS PL	90005	10	135B193   973	5504028187	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.06262	-118.31173	Remodel and addition of existing school.  14100 sq ft conditioned plus 1400 sq ft outdoor hardscape areas.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46089	18041-20000-45258	16816 W ADDISON ST	91436	5	171B133   645	2259005008	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.16198	-118.49956	Plan check for a PV1 roof-mounted PV system. System size is 11.89 kWdc/13.6 kWac and consists of (2) inverters, (41) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46090	16041-20000-10295	21650 W OXNARD ST 23rd Floor-Corridor	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for energy only. TI to corridor on 23rd floor of high rise building. New lighting (incl. emergency). 1,490sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46091	19041-10000-37384	3729 N CAHUENGA BLVD	91604	4	159B177    82	2425003023	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.13543	-118.36192	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46092	14041-20000-19990	13947 W CHANDLER BLVD	91401	4	171B153    85	2247012009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Expired	08/26/2016 12:00:00 AM	ADDRESS	34.1687	-118.4372	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD.(1) Fronius USA 10.0-1 UNI inverter(40) Hyundai HiS-M250MG pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46093	17041-10000-23043	13836 W OSBORNE ST	91331	6	198B153   947	2640008002	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.23545	-118.43484	PC FOR ROOF MOUNTED PV ON A SFD. 18 MODULES WITH SINGLE INVERTER.SYSTEM SIZE 3.8KWAC. PROTECTION FOR EQUIPMENT SHALL BE PROVIDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46094	16041-20001-44881	16702 S VERMONT AVE	90247	15	066B197    92	6121008038	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	33.87938	-118.29102	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on commercial building. Interconnect with a 200A MSP. 3.8kW ungrounded system. (15) 300W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46095	15041-20000-14175	16940 N NORDHOFF ST #3525	91325	12	195B133     9	2688025012	(Q)C2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	07/25/2015 12:00:00 AM	ADDRESS	34.23558	-118.50166	Plan check for Title 24 only El Pollo Loco T.I.  install LED lighting in dining room. Total area: 1,151 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46096	14041-10000-00921	800 S FIGUEROA ST #101	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.04771	-118.26116	permit to be pulled at EPC counter only. PC for energy only. Hirise. Emergency lighting and exit signs are existing to remain. TI TO (E) RESTAURANT. PLAN CHECK PER INSPECTOR REQUEST AND FEES FOR new LIGhts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46097	17041-20000-18764	4467 E HUNTINGTON DR SOUTH	90032	14	142-5A229 398	5305037031	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.08326	-118.18906	Plan check for solar pv array, roof-mounted on SFD.3kW ungrounded system. (10) 275W pv modules.Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46098	17041-10000-44175	1440 N ALTA VISTA BLVD	90046	4	147B181  1185	5548018040	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.09712	-118.34686	PC FOR TITLE 24 ENERGY ONLY FOR NEW LIGHTS IN LOBBY OF GROUND FLOOR AND GYM ON THE 1ST FLOOR. TOTAL AFFECTED AREA 900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46099	19041-10000-43399	21721 W VANOWEN ST	91303	3	183B105   926	2138006034	(WC)RIVER-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.1939	-118.60204	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46100	18041-10000-25569	8307 W FOOTHILL BLVD	91040	7	207B189  1034	2555024022	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.02	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.25984	-118.3138	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46101	12041-20000-19982	2030 S SAWTELLE BLVD	90025	11	126B153   753	4261032056	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM			Corrections Issued	08/23/2012 12:00:00 AM	ADDRESS	34.04031	-118.44289	T-24 and emergency lighting plan check for new restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46102	18041-10001-47353	606 N WESTERN AVE	90004	13	141B193   857	5521002005	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	34.08193	-118.30887	REVISION OF LIGHTING SYSTEM OUTSIDE LIGHTING PROVIDED TITLE 24 UPDATE((((((TENANT IMPROVEMENT IN FURNITURE STORENEW CIRCUITS AND LIGHTING SYSTEMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46103	16041-20003-11634	1213 N DOUGLAS ST	90026	1	138A211    25	5405002004	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.07399	-118.25251	Relocation of (N) distribution equipment.  (((PV1.  Install 5.2 kW roof mounted solar system.  (16) modules with a transformerless 5kW rated central inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46104	19041-20000-41867	6611 W SANTA MONICA BLVD	90038	4	144B185  1261	5532023***	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.09086	-118.33369	T24 PLAN CHECK FOR TI REMODEL OF EXISTING LOW RISE OFFICE. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 5222 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46105	17041-10000-07411	830 S OLIVE ST	90014	14	127-5A209  95	5144018026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM			PC Info Complete	03/08/2017 12:00:00 AM	ADDRESS	34.0443	-118.25741	TI to an existing three story commercial building.  Adding new lighting and new controls to existing panels. Plan check for energy only.  Total square footage - 3110.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46106	18041-20000-28730	2732 W LOCKSLEY PL	90039	4	151-5A207 185	5438018021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.10749	-118.26237	Plan check for PV roof mounted system, system size: 7.6kW with 24 pv modules and 2 inverters(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46107	13041-10000-32165	1608 W SUNSET BLVD	90026	13	139-5A209 185	5404018002	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.07673	-118.25781	REMODEL EXISTING DINERPLAN CHK IS FOR TITLE24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46108	19041-10000-51124	617 W 7TH ST 704	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.04779	-118.2571	PC FOR T-24 ENERGY ONLY. AFFECTED AREA 2195 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46109	19041-10000-14224	945 W 8TH ST	90017	14	129A207    16	5144009079	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Closed	06/06/2023 12:00:00 AM	ADDRESS	34.04892	-118.26244	Plan check for temporary power for construction of new design build mixed use building. Highrise Building permit# and scope:  18010-10000-03720 ATTN ALLEN M. ***100% PDPP partial plan check submittal for FLS, Green, DAS and Structural***New 59-story mixed-use Residential and Retail building, 784 residentail units and 6,700sf of commercial uses over abv grade Parking and 2 levels of subterranean Parking garage	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46110	17041-10002-23530	1210 S SOTO ST	90023	14	121-5A221 102	5170018018	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.10	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM			PC Info Complete	09/24/2018 12:00:00 AM	ADDRESS	34.02759	-118.21931	"Changes to an approved set of plans. All changes are clouded under delta ""CB3"". Changes include replacing lighting fixtures in the kitchen areas, revising Title 24 calculations, and revising emegency photometrics."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46111	13041-10001-16306	101 W WORLD WAY	90045	11	090B165    54	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	PIN	33.94482328	-118.40058888	PLAN CHECK ONLY. plan check fees on original application.SUPPLEMENTAL PC FOR T24 ENERGY ONLY.  TI  LIGHTING FOR THE ATTACHED PARKING BUILDING ADDED TO THE SCOPE. 380,707 SQFT, EMERGENCY LIGHTING.note: SUBMITAL-2 WAS CHARGED TO ACCOUNT FOR OUTDOOR LIGHTING THAT WAS NOT ACCOUNTED FOR IN SUBMITTAL-1. UNDER ORIGINAL PC: LAX parking structure 101.  Replacement of older elevator motors, upgrading of lighting in elevator towers.  Title 24 plan check only, permit to be issued at electrical plan check counter. scope of work < 400A. 2 TOWERS FOUR FLOORS, ONE BUILDING ONE SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46112	14041-20000-11909	7453 N LOMA VERDE AVE	91303	3	186B109   512	2112013002	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.20615	-118.58973	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46113	12041-20000-30537	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.24143	-118.56249	Plan check for power and energy. Core and shell. 2450 conditioned and 1456 unconditioned.  Existing Low-rise Commercial Building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46114	19041-10000-36255	2823 N HYPERION AVE	90027	4	151-5A205 146	5433027018	C4-1D	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.10865	-118.27177	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46115	18041-20000-08553	6601 W SANTA MONICA BLVD	90038	4	144B185  1262	5532023016	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.09086	-118.33347	Plan check for a fire alarm system for an existing commercial building. Fire alarm consists of (1) FACP, (1) annunciator, and (147) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46116	17041-10000-34398	3303 W VERNON AVE	90008	10	111B185    43	5023009024	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.00379	-118.32967	REPLACE EXISTING FIXTURES WITH LED FIXTURES- TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46117	17041-10000-01087	7919 N CHERRYSTONE AVE	91402	6	189B153   600	2214004014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2017 12:00:00 AM			PC Info Complete	01/17/2017 12:00:00 AM	ADDRESS	34.21451	-118.43732	PV, INSTALL 6.62 KW DC  ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(25) MODULES: JINKO 265 W (25) MICROINVERTERS: 25 ENPHASE M215-60-2LI-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46118	16041-10000-15111	730 E 110TH ST	90059	8	088-5A207 312	6071007030	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	33.93556	-118.26184	PV1, rooftop solar installation 1.72 kW AC (8) HiS-M250MG and  (8) M215-60-2LL-S22.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46119	17041-10002-04504	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			PC Info Complete	02/16/2018 12:00:00 AM	ADDRESS	34.05007	-118.2433	PC for changes to approved set. Changes include addition of ciruits, equipment and changes in lighting. All changes clouded under delta 4,5 and 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46120	11041-10000-03148	11611 W SAN VICENTE BLVD 1st floor	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	T-24 and emergency lighting plan check for a first floor tenant remodel in a  highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46121	18041-20000-08960	14837 W WYANDOTTE ST	91405	6	186B149   708	2218020023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.20313	-118.4566	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222pv1install roof mounted pv system sized 14.6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46122	19041-10002-08444	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM			Reviewed by Supervisor	07/03/2019 12:00:00 AM	ADDRESS	34.07417	-118.26931	Plan check for a 408KW AC / 452KW DC roofmounted PV2 system, located on the top of a commerical building and (2) carport. Scope includes (1222) modules, (90) strings, (18) inverter interconnectring through the load centers to back feed the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46123	14041-20001-24864	7006 S HOOVER ST UNIT 6	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #6.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46124	14041-20001-13336	12659 N DORINA PL	91344	12	219B133    32	2602019008	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.30095	-118.50533	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.43KW INTERCONNECTED WITH MAIN PANEL (2) TRANDFORMERLESS INVERTERS SOLAREDGE SE3800A(37) TRINA SOLAR MODULES TSM-PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46125	16041-10000-41116	4091 S REDWOOD AVE STE 102	90066	11	108B153   893	4230006032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Issued	01/12/2017 12:00:00 AM	ADDRESS	33.99105	-118.44076	T-24, PC FOR ENERGY ONLY. TI TO FOR OFFICE SPACE WITHIN AN APARTMENT BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2014 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46126	16041-10001-26138	21400 W NORDHOFF ST	91311	3	198B105   199	2779018021	C2-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM			PC Approved	08/22/2016 12:00:00 AM	ADDRESS	34.23522	-118.59776	EXPEDITE PER APPLICANT REQUEST.((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 52.08KWdc / 50.00KWac (3 phase system). (168)MODULES-CANADIAN SOLAR 310(168)OPTIMIZERS-SOLAREDGE P700 OPTIMIZER(4)INVERTERS-SOLAREDGE SE12.5K	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46127	16041-20000-24635	10730 N MEMORY PARK AVE UNIT D	91345	7	207B145   239	2649003028	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.26537	-118.46322	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED TO MSP FOR UNIT D.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46128	14041-10000-12880	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Expired	06/13/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	T24 FOR OUTDOOR LIGHTING FOR NEW CREDIT UNION FOR POLICE DEPARTMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46129	13041-10000-00369	910 S TOWNE AVE	90021	14	124-5A211 167	5132003001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM			Reviewed by Supervisor	02/25/2013 12:00:00 AM	ADDRESS	34.03525	-118.2487	new building for retail space. 2 story building with sub. parking. non hazardous location. t24 with power plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46130	18041-10000-20970	11938 W COHASSET ST	91605	2	186B165   401	2317013018	R1-1, RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.20654	-118.39349	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 7.6KWAC/ 7.25KWDCSCOPE INCLUDES 25 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46131	19041-20000-00155	6100 W CENTER DR 6th flr	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	33.97733	-118.3922	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46132	19041-20000-11088	5951 N VARIEL AVE C-5	91367	3	177B105    94	2149002025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.17855	-118.59308	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN EXISTING LOW RISE OFFICE BUILDING. SCOPE OF WORK INCLUDES 1 FA PANEL AND 72 FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46133	16041-20000-14772	10548 N LUBAO AVE	91311	12	207B113   320	2708019036	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			Reviewed by Supervisor	05/13/2016 12:00:00 AM	ADDRESS	34.26101	-118.56729	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. System size: 2.88kW. Ungrounded system.(12) EnPhase M250 microinverters.(12) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46134	16041-20001-21243	10356 W DIAMOND ST LOT 19	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC in Progress	06/27/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46135	17041-10000-46016	900 N NORTH BROADWAY 1010,1020	90012	1	135A215   238	5414013901	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	04/13/2018 12:00:00 AM		Issued	04/13/2018 12:00:00 AM	ADDRESS	34.06408	-118.23726	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM (E) TWO RETAIL SPACE TO ONE (N) RESTAURANT AND OUTDOOR DINING AREA. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS AND LIGHTS.  A-OCCUPANT LOAD IS GREATER THAN 100. TOTAL AFFECTED AREA IS 3544 SQ. FT. B#17016-10000-37943	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46136	15041-10001-24624	725 S FIGUEROA ST 41st Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	Changes to an aprroved set. Note, changes on delta 1. Changes includes new lighting in the corridor and elevator lobby area. Total Sq. Ft. 2000. (((Energy plan check for (2) restrooms located in an office of a high rise building. Total 518-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46137	19041-10000-53848	1123 N BENTON WAY	90026	13	141A205   131	5402001006	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	34.08132	-118.27019	Plan check for PV1 system, system size is 3.480kw, 12 modules with p320 solar edge optimizers and 1 Se3800H inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46138	12041-20000-16236	12717 W HORTENSE ST	91604	2	168B161   710	2362022012	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.15501	-118.41011	Solar system 7.5 kw single family dwelling, with reduction in main service disconnect from 200 amperes to 175 amperes.  Existing permit - 12041-20000-14220.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46139	18041-10000-15282	1999 S AVENUE OF THE STARS 9TH FLR	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI IN AN EXISTING MEN'S & WOMEN'S RESTROOMS ON THE 9TH FLOOR. TITLE 24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46140	18041-10000-18482	550 S BERENDO ST	90020	10	135B197   964	5502023019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.06407	-118.29399	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46141	19041-10000-38330	15031 W RINALDI ST	91345	7	213B145    64	2664022028	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Issued	09/25/2019 12:00:00 AM	ADDRESS	34.27918	-118.46029	POWER PLAN CHECK ONLY FOR TI OF A MEDICAL FACILITY IN A CLINIC.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46142	11041-10001-23911	2020 S BUNDY DR	90025	11	123B149   367	4259020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Expired	08/08/2014 12:00:00 AM	ADDRESS	34.03347	-118.45477	tI WORK FOR AN EXISTING HARWARE STORE. ENERGY, OUT DOOR AND INDOOR, ADD GEN SET, POWER AND ENERGY. NOT A HIGH RISE. FIRE ALRM WILL BE DIFFERED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46143	17041-20003-01171	13767 W FOOTHILL BLVD	91342	7	225B153   444	2509015007	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.31003	-118.43331	CHANGES TO APPROVED SET. CHANGES TO LIGHITNG SOURCE. REVISED LIGHITNG LAYOUT AND UPDATED TITLE T24. PC ONLY - PERMIT ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46144	18041-10000-15617	4500 N WOODMAN AVE 124, 207,-301	91423	4	168B157   929	2360002030	R1-1-RIO, R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.15306	-118.43102	PC FOR T-24 ENERGY ONLY. TENANT IMPROVEMENT. SCOPE INCLUDES NEW PANEL, LIGHTING AND RECEPTICAL. TOTAL AFFECTED AREA IS 12306 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46145	14041-20000-08150	10151 N FERNGLEN AVE	91042	7	204A197   325	2558026028	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Expired	04/20/2016 12:00:00 AM	ADDRESS	34.25378	-118.29443	Roof mounted PV system with size 2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46146	15041-10000-15420	1251 S EDRIS DR 1-5	90035	5	132A167   195	4330024021	RD1.5-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			05/20/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.05575	-118.39818	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46147	11041-10000-08613	1700 N VERMONT AVE	90027	4	147B197   232	5590026004	C4-1D	Central	Hollywood	Greater Griffith Park		1891.01	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			PC Info Complete	06/20/2011 12:00:00 AM	ADDRESS	34.10191	-118.29159	STARBUCKS TENANT IMPROVEMENT.  TITLE 24 PLAN CHECK ONLYPERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46148	15041-20001-30807	7815 N LINDLEY AVE	91335	12	189B125   946	2102017136	(T)R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM			PC Approved	09/19/2015 12:00:00 AM	ADDRESS	34.21245	-118.52759	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.New 3kW ungrounded inverter output to combine with existing 3.8kW inverter output in 125A subpanel.(15) 265W pv modules on new inverter.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46149	19041-10000-51223	1406 3/4 N KENTER AVE	90049	11	141B137   105	4493019012	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	01/02/2020 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.08042	-118.49312	PER ASSEMBLY BILL# 1414 $0.00 FEES(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION WITH AN EXISTING SERVICE OF 400 AMPS. INSTALLATION INCLUDES 36 MODULES (HANWHA Q-CELLS 315W), 1 CENTRAL INVERTER (SE10000H-US), 36 OPTIMIZERS (P400), 3 ENERGY STORAGE SYSTEM, 1 PANEL OF 125 AMPS, AND 1 PANEL OF 200 AMPSSYSTEM SIZE: 11.34 KW DC; 10 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46150	18041-10000-16434	12917 W KAGEL CANYON ST	91331	7	204B161   238	2623016019	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Issued	05/03/2018 12:00:00 AM	ADDRESS	34.25614	-118.41423	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 15 MODULES (HANWHA Q CELL, Q-PEAK 295 ), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS P320) WITH A CENTRAL INVERTER (SOLAR EDGE SE3800H-US).  SYSTEM SIZE IS 4.43  KWdc AND 3.8 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46151	11041-10002-13752	3425 N GREEN VISTA DR	91436	5	159B133   163	2287010071	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.1327	-118.499	Modification to previously approved set of drawings to move PV feeder to a 400A subpanel.<<<<New 16.7 KW pv solar roof mounted system. for a single family resisdence.  All clearances have been obtained via permit # 11041-40000-13752.  Regular plan check.  All wiring shall be in shade, and service is rated 400 ampere with 200 ampere main circuit.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46152	11041-20000-12719	4151 W PROSPECT AVE 1ST FLR	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM			PC Approved	06/20/2011 12:00:00 AM	ADDRESS	34.10191	-118.28217	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING T.I. PRECISION WORK ROOMS 134,135 AND 135B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46153	13041-10000-06281	4108 S DEL REY AVE	90292	11	108B153  1216	4230005040	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			03/11/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.98836	-118.4448	New fire alarm system for a 4-story 77 unit mixed used apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46154	19041-10000-46805	8561 N SEPULVEDA BLVD	91343	6	192B145    51	2654020012	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.22644	-118.46788	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46155	14041-20000-15794	11601 W WILSHIRE BLVD Ste. 1950A-1950B	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	TI to	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46156	11041-10000-25506	7621 S FIGUEROA ST	90044	8	099B201   213	6020020027	C2-1VL	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	Public Safety Only			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	33.97005	-118.28302	INSTALLATION OF FIRE ALARM SYSTEM WITH CENTRAL STATION MONITORING FOR A 4-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46157	16041-10001-07374	777 S SANTA FE AVE ANNEX	90021	14	124-5A217 270	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.03354	-118.23024	Changes to approved set.  Removing 2 duct detectors from 3rd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46158	17041-10000-38821	15445 W ROSCOE BLVD	91343	6	192B145   366	2654027014	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.22158	-118.46885	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ FT 65800.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46159	16041-20002-00487	14031 W VICTORY BLVD Apt 3	91401	2	180B153  1077	2238025005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			03/08/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	34.18683	-118.43882	[[[[ 3/8/16 changes to the description to adjust the number of modules from 9 to 12 modules]]]]]Installation of new roof mounted PV array on existing apartment building for Apt 3.  System consists of a 3 kWAC inverters with (9) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46160	18041-20000-39165	3630 N LONGVIEW VALLEY ROAD	91423	4	162B149   580	2274011001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.1369	-118.45071	Plan check for battery energy storage system install in to existing PV system, Tesla Powerwall 2.0 13.56kWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46161	19041-30000-14209	706 N ALVARADO ST	90026	13	138A207    49	5404008010	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.20	Electrical	Electrical	Apartment			04/18/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	34.07393	-118.26551	Plan check for a fire alarm system for a 5-story, 34-unit apartment building. Fire alarm consists of (1) FACP and (88) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46162	17041-20000-34178	14317 W JOY DR	91331	6	198B153  1028	2644027240	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24171	-118.4451	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46163	12041-10000-23588	19524 W STAGG ST	91335	3	189B117   933	2116010025	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Expired	11/10/2014 12:00:00 AM	ADDRESS	34.21121	-118.55897	FOR A SFD, ROOF-MOUNTED 4.08KW PHOTOVOLTAIC SYSTE USING MICROINVERETERS.  Maximum Enphase Engage cable length is 51'.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46164	12041-20000-16150	2614 S GRAND AVE	90007	9	121-5A205 219	5122013014	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.02592	-118.27242	medical office with no treatment performed on the site.  No change in lighting, no T24 required, only install circuits in existing panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46165	11041-20000-01304	777 S FIGUEROA ST 10th-11th Floor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM			PC Info Complete	01/21/2011 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check T24 Energy (general/emergency) for 10th & 11th floor video conference room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46166	16041-20000-23096	19530 W PEARL LN	91324	12	198B117  258	2761035017		North Valley				1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Expired	09/11/2018 12:00:00 AM				Plan check for PV roof mounted system. System size: 3.0kW with 12 AC Modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46167	13041-20001-33633	19343 W OLIVOS DR	91356	3	168B117   173	2175006012	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.15824	-118.55462	EXPEDITE FEES ONLY        <<New rooftop PV system for an existing sfr.   System uses Solar Edge Power Optimizers.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46168	17041-20000-43068	20700 W SESNON BLVD	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.29545	-118.58467	pv1install roof mounted pv system sized 5.7kw interconnected with msp.new development, general site address to be updated accordingly.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46169	17041-10001-03359	134 S DENSLOW AVE	90049	5	138B149   148	4366023005	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM			PC Approved	03/16/2017 12:00:00 AM	ADDRESS	34.07366	-118.45826	EXPEDITE FEESROOF MOUNTED PVPC FOR PV SYSTEM USING 7.6KW INVERTER WITH BATTERY BACK UP SYSTEM, USING TESLA POWER WALL. INSTALLING BACK UP LOAD CENTER AS WELL. TOTAL OF 16 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46170	13041-10003-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	33.94286	-118.39982	changes to permitted plans: motors for baggage system were downsized and  some loads were are to be fee from different busduct;overall  changes are reduction of loads on busducts; all changes are clouded))))))))))Replacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46171	17041-20001-05550	11538 W CHIQUITA ST	91604	2	162B169    39	2368011012	RE11-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			PC Approved	03/14/2017 12:00:00 AM	ADDRESS	34.14442	-118.3837	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 225A MSP.11.8kW ungrounded system [5.2+6.6]. (42) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46172	14041-20000-03338	1411 S TOBERMAN ST	90015	1	127-5A203 318	5135023003	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Apartment			02/05/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.04223	-118.27725	600A SERVICE UPGRADE FOR EXISTING APARTMENT BUILDING. NEW FEEDERS TO EXISTING TENANT SUBPANELS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46173	14041-10000-09663	1426 S CHANNING ST ste # A	90021	14	120A215    22	5167017014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.02448	-118.23801	T24 only. Remove HID light fixtures and replace with new fluorescent fixtures. Total area 3912 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46174	12041-10000-30858	5949 N VAN NUYS BLVD	91411	4	177A151   185	2244001020	C2-1VL, M1-1, P-1VL, R4P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	PIN	34.17831798	-118.44921314	New Keys Chevrolet Dealership with Display Room - Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46175	15041-20001-07240	6250 N TOPANGA CANYON BLVD #F1520	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Info Complete	09/01/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	09-01-2015 Change to approved set of plans. Changes include wattage and manufacturer of fixture A, AE and C and panel from split bus panel to subpanel. Changes apply to delta 4 only. {{{Plan check for first time tenant power and energy (susiecakes).}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46176	15041-10000-36104	1640 S SEPULVEDA BLVD 2ND FL	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM			Corrections Issued	10/28/2015 12:00:00 AM	ADDRESS	34.04838	-118.44468	PC FOR ENERGY. T.I FOR TRINET OFFICE. TOTAL AREA 11293 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46177	07041-10001-05451	442 S LAKE ST 1-15	90057	1	133-5A203  43	5154031023	R4-2	Central	Westlake		YES	2088.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.06177	-118.27473	Modification to approved set of drawings.  Seperate the MSA and HDP from the pull section.<<<New  15 unit apartment.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46178	10041-20000-15167	1870 S VETERAN AVE	90025	5	129B153   821	4323007***	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	ADDRESS	34.04744	-118.43865	replacing light fixture in apartment common areas. No emergecy lighting. P/C is for Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46179	19041-10000-21768	2530 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.10322	-118.25902	Enery plan check for a retail T.I located in a commercial building. Scope includes new lighting and equipment with a total lighting area of 1382-SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46180	17041-10000-11994	1550 N MALTMAN AVE	90026	13	144A203    45	5429024023	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Issued	04/13/2017 12:00:00 AM	ADDRESS	34.09062	-118.27619	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 13400 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46181	15041-10002-01054	9301 N TAMPA AVE #134	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	((((4/22/2015))))changes to an approved set of plans.  changes noted delta 2.  plan check only.Supplemental application for changes to an approved set of plans. Changes are marked as Delta 1 and include a change to light fixtures and Title 24 Compliance Form calculations. *******Previous Work Description*********TENANT IMPROVMENT, INTERIOR NON BEARING PARTITIONS IN (E) RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46182	19041-20000-53262	110 E 9TH ST 9TH FLR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	Plan check for Title 24 Energy in existing space. Installed new lighting in addition to existing lighting. Total area: 12744 sq ft. B#19016-10000-14238	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46183	15041-10000-34607	529 S CERES AVE	90013	14	126A215    56	5147017022	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.04085	-118.24064	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46184	18041-10000-31838	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			08/21/2018 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	04/09/2021 12:00:00 AM	ADDRESS	34.06259	-118.35341	New 21-Story, 285 Unit, Apartment with 2 levels of subterranean Parking.15 Typical Floor Plans. Scope includes adding a new 5000A 480/277V 3 Phase 4 Wire Service. Bldg Permit: 17041-10000-04785 & 18016-10000-22952Note: Plan checker to verify Fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46185	14041-20000-09372	4222 N VINELAND AVE	91602	2	165B173  1260	2366020002	[Q]C2-2D	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Closed	09/07/2018 12:00:00 AM	ADDRESS	34.1455	-118.37004	New highrise hotel corridor wall sconces.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46186	14041-20000-15494	6056 N SIMPSON AVE	91606	2	177B169   627	2334015069	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.18101	-118.38873	6KW PV1 roof-mounted system with (24) SolarWorld Poly SW250 modules, and (24) Enphase M215-60-2LL-S2x microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46187	16041-20000-08649	8820 S SEPULVEDA EASTWAY	90045	11	096B165   920	4123006025	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Apartment			05/03/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	33.95623	-118.3946	Plan check for new 136 units apartment.  5 stories with 2 stories of subterranean parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46188	11041-10000-20318	11401 W VENTURA BLVD	91604	2	162B173   536	2368023041	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.14002	-118.37918	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46189	17041-10000-38211	14920 W PARTHENIA ST	91402	6	195B149   610	2653010018	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.228	-118.45803	REPLACE OUTDOOR HID WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46190	16041-10000-41815	19404 W PAUMA VALLEY DR	91326	12	213B117   224	2822027009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.28113	-118.55513	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.04KWac.(22)AC MODULES-SUNPOWER SPR-X21-335-BLK	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46191	16041-10000-45094	8000 S FIGUEROA ST	90003	8	099B201   782	6032030001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	33.96667	-118.2825	PC for energy only. Outdoor title 24. Remove HID fixture and replace with new LED fixtures. Area: 6,350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46192	16041-20000-06237	13457 N ELDRIDGE AVE	91342	7	225B157   181	2510012031	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.31634	-118.42302	Plan check for a PV1 roof-mounted PV system. System size is 6kWac and consists of (25) modules, (25) micro-inverters (EnPhase M250), and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46193	14041-20000-01997	11535 N VINEYARD LANE	91331	7	213B165   444	2532010***	(Q)RD2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.27951	-118.40242	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46194	13041-20000-33889	15225 W WEDDINGTON ST	91411	4	172-5A147 126	2250004034	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.16743	-118.46493	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.8 KW AC USING 27 MODULES. ENPHASE M215. MICROINVERTER. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46195	16041-20000-22494	1207 W MIRAMAR ST	90026	1	132A209     6	5152012022	CW	Central	Westlake	Downtown Los Angeles	YES	2080.00	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Issued	03/10/2017 12:00:00 AM	ADDRESS	34.05748	-118.2577	permit fee $0.00 by state senate  bill.Plan check for PV roof mounted system. System size: 38kW with 150 modules and 5 inverters (7.6kW) on Commercial Building.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46196	19041-10000-47202	11128 W GAULT ST	91605	2	183B173   145	2319022001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	12/07/2020 12:00:00 AM		Permit Finaled	08/08/2023 12:00:00 AM	ADDRESS	34.19927	-118.3737	Zero dollar fees due to AB1414. NEW ROOF MOUNTED 204KW PV SYSTEM WITH 510 @ (400W) PV PANELS AND 255 OPTIMIZER WITH TWO  CENTERAL INVERTER RATED @ 99KW & 66KW ON A COMMERCIAL BULDING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46197	15041-10000-22083	18840 W VENTURA BLVD	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.17186	-118.54425	NEW FIRE ALARM SYSTEM TO AN (E) OFFICE BUILDING. TOTAL FIRE ALARM DEVICES 38 DEVICES AND 1 FIRE ALRM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46198	19041-10001-32469	1749 S ORANGE GROVE AVE	90019	10	126B173   227	5066019028	R1R3-RG	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.04416	-118.36773	change of an approved set, change under delta 1 only. change include changing the lay out of the solar modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46199	17041-10000-17966	3785 W WILSHIRE BLVD unit 102AB	90010	10	135B193  1023	5503030903	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM			PC Info Complete	05/30/2017 12:00:00 AM	ADDRESS	34.06187	-118.30858	PC FOR OFFICE T.I. (CHANGE OF USE FROM RETAIL TO OFFICE) ON FIRST FLOOR FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 2020 SQ.FTINSTALLING NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46200	14041-20000-31865	11938 W RUNNYMEDE ST #A & B	91605	6	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.20563	-118.39354	Roof mounted PV system with optimizers.  PV system 3 of 3 size 4.25KW.Note: zoning clearance is on 14041-20000-31858	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46201	16041-20001-04994	4410 S BUDLONG AVE	90037	9	111B197   141	5017017026	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	34.00325	-118.29574	4.25.2017 - Plan check for modifications to approved set. Remove 12 AC rooftop units, replace with 4 rooftop HP units and associated FC units indoors. Update plans to show new load and circuiting. Update conductor size of two feeders on SLD. Delta 4 changes.========PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE FROM CHURCH/SCHOOL BLDG. TO ELEMENTARY SCHOOL. FIRE ALARM VARIANCE HAS BEEN SUBMITTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46202	15041-20000-02760	6530 N SEPULVEDA BLVD	91411	6	180B145   491	2235002005	R1-1, R4-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			01/29/2015 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.18936	-118.46595	NEW 68 UNIT APARTMENT. PARKING GARAGE. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46203	13041-20001-16470	9043 N RESEDA BLVD	91324	12	195B125    56	2770004006	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.23486	-118.53635	(((this is supplemental application for pc only for t24 energy. original permit already issued under application 13041-30000-16470))))INSTALL 15 FLUORESCENT FIXTURES 2X32W	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46204	13041-10000-29528	1875 S CENTURY PARK EAST ste 1970	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.06115	-118.41457	TITLE-24 PART 6, ENERGY FOR LIGHTING IN AN EXISTING HIGH-RISE BUILDING. WORK IS FOR TENANT IMPROVEMENT TO EXISTING OFFICES ON THE 19TH FLOOR. EMERGENCY LIGHTING CK WILL BE FED VIA EXISTING EMERGENCY CKT ON EXISTING EMERGENCY PANEL19ELA(480V) AND PANEL 19EPA(208V) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46205	15041-20002-43125	9055 N TELFAIR AVE	91352	6	195B165    94	2631005029	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM			PC Approved	03/25/2016 12:00:00 AM	ADDRESS	34.23385	-118.39436	3.25.2016 - Plan check for changes to approved set. Upgrading main panel that solar array interconnects with to 225A with 200A main breaker. Update plans to reflect.---02/19/2016 Supplemental plan check for the deration of the main service panel breaker. Service load calculations have been included.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46206	12041-20000-30969	10150 W NATIONAL BLVD	90034	5	120B161    76	4313001019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM	01/10/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.02883	-118.40691	Plan check for energy and emergency lighting. Office ti, existing tenant. Sinlge-story building. 3003sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46207	16041-20000-38179	5950 N LAUREL CANYON BLVD	91607	2	177B165   769	2340005037	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			Corrections Issued	01/19/2017 12:00:00 AM	ADDRESS	34.17861	-118.39631	PV2.  Install 48 kW DC roof mounted grid-tied PV system with line side tap.  (160) modules with Enphase C250 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46208	16041-10000-28853	14655 W SHERMAN WAY	91405	6	183B149    22	2218023020	M1-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.2014	-118.45303	OUT DOOR LIGHTING REPLACEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46209	19041-20001-33073	14741 N SAN FERNANDO ROAD	91342	12	228B133    49	2601011015		North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			Corrections Issued	09/05/2019 12:00:00 AM	PIN	34.31861247	-118.5054545	Plan check for hazardous location for automatic control the methane flow metering station with UPS back up.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46210	14041-10000-16825	1113 E 27TH ST	90011	9	118-5A209 282	5119011019	[Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.01764	-118.25483	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46211	15041-20002-17238	14859 W BESSEMER ST	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM			Corrections Issued	08/11/2015 12:00:00 AM	ADDRESS	34.18089	-118.45722	FULL PLAN CHECK DUE TO CONNECTION TO NEW 600A SWITCHGEAR. THIS IS PLAN CHECK AND PERMIT FOR THIS TENANT CORE AND SHELL ONLY. THIS IS PART OF 3 UNIT SUBDIVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46212	13041-20001-10724	19313 W STARLIGHT DR Pv-1	91356	3	168B117    31	2175003014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.16033	-118.55442	(((application is for changes to approved set of plans. using power optimizers. ))))PV-1. Plan check for addition to existing PV system. Addition of a 3kW inverter. Existing 225A service. loads calcs provided for downgrade breaker.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46213	13041-10000-19801	13258 N LA TIERRA WAY	91342	7	225B165    19	2580018245		North Valley		Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.31387	-118.40324	PV1.  Install 3.456 kW AC roof-moutned solar array, interconnect into main service panel.  Microinverters.  16 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46214	18041-20000-20242	1411 W 190TH ST 8th Floor	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	33.85852	-118.30317	Plan check for power and energy for T.I. complete 8th floor total newly connected load exceed 400A.  Total area: 18923 sq ft.B#18016-10000-14095	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46215	17041-20000-15058	52 E WINDWARD AVE	90291	11	106-5A143  42	4226009014	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	33.98724	-118.47269	"ti to an existing commercial 2 story building.  new 600 amp service.  plan check for power and energy total square footage 4072.""COMPLY WITH DEPARTMENT ORDER effective date11/16/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46216	13041-10000-13234	23001 W CALVERT ST	91367	3	177B097   649	2039009034		South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills			1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.18114	-118.62773	PV1.  Interconnect roof-mounted PV system into upgraded 400A main service panel.  {60 modules: Trina Solar TSM-250PA05.08} {3 transformerless inverters: Power-One PVI-6000-OUTD-US, PVI-3.0-OUTD-S-US, PVI-3.6-OUTD-S-US}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46217	16041-20000-31891	12349 N ARAGON WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29517	-118.45487	Plan check for roof-mounted solar array on SFD. Interconnect with 200A MSP.3kW ungrounded system. (11) 305W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46218	11041-10000-17464	1629 N ECHO PARK AVE 1-7-bldg  5	90026	13	141A209    33	5419008036	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			08/17/2011 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.08252	-118.25475	NEW 7-UNIT APARTMENT BUILDING (BLDG 5).  PLAN CHECK FOR ENERGY AND POWER.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46219	16041-20000-28164	22951 W ROSCOE BLVD	91304	12	192B097   589	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	PIN	34.22262962	-118.62405906	Plan check for power and energy. Project site is a new warehouse. Work includes a new 3000-amp service, associated distribution boards and load, and a total lighting area of 42,645 sq. ft.Note: Building application has been filed under 16010-10000-00122	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46220	14041-10000-06727	1712 W 1ST ST	90732	15	018B189   233	7559013013	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	33.74383	-118.31411	PV1, INSTALL 8 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U(32) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46221	15041-20000-38981	8431 N RANCHITO AVE	91402	6	192B153   384	2638036011	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.22435	-118.43682	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KW. (18) MODULES-KYOCERA KU265ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46222	18041-20000-02914	7601 N TOPANGA CANYON BLVD	91304	3	186B101   129	2012022018	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.20851	-118.60619	Plan check for a PV2 roof-mounted PV system. System size is 18 kWac and consists of (3) inverters, (53) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46223	17041-10000-06702	10850 W MOORPARK ST	91602	4	165B173   352	2423015019	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.15012	-118.36774	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR) TOTAL AREA 39650 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46224	14041-10000-15464	1511 S ABBOT KINNEY BLVD	90291	11	108B145  1406	4241036012	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	33.99033	-118.46425	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. SHOW ROOM. 1837 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46225	10041-20002-11058	15206-15210 W PARTHENIA ST Bldg 1& 2	91343	6	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills			1175.30	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM			PC Approved	02/08/2011 12:00:00 AM	ADDRESS	34.2281	-118.46381	remove generator and use battery units form lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46226	12041-10000-19381	20426 W LABRADOR ST	91311	12	201B113   320	2748009012	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.24889	-118.57805	3.12KW Rooftop mounted photovoltaic system for an existing single-family-residence.  System uses Enphase M215 Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46227	13041-20000-31460	11971 N SALEM DR	91344	12	216B133   391	2606019026	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.28772	-118.50802	PV1 MICROINVERTER 8.1KW. 30 MODULES AND MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46228	18041-10000-31590	7400 N SEPULVEDA BLVD	91405	6	186B145   515	2221009014	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.20497	-118.46583	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXUTRES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46229	14041-20000-21108	10019 N OAK PARK AVE	91325	12	204B133   580	2694017022	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.25273	-118.50523	PV1.  Install 5.18 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46230	14041-20000-07515	12059 N DELANTE WAY	91344	12	216B125   380	2601072012	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Expired	04/28/2016 12:00:00 AM	ADDRESS	34.29185	-118.52743	Roof mounted PV system with 8.10 KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46231	14041-20002-09444	5955 N VANALDEN AVE	91356	3	177B121   670	2156008022	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	ADDRESS	34.17878	-118.54992	Changes from previously approved plans.  Relocate inverter and AC disconnect mean.  Note: Permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.****Previously Description****PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46232	19041-20001-28149	7660 N WILBUR AVE pv1	91335	3	186B121    26	2103015014	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM			PC Approved	08/06/2019 12:00:00 AM	ADDRESS	34.21009	-118.54462	expeditepv1install of roof mounted pv system sized 3.8KW AC interconnected with msp.  this is an addition to an existing pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46233	19041-10000-46824	1200 S FIGUEROA ST	90015	14	126A207   321	5138015048		Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Info Complete	11/14/2019 12:00:00 AM	ADDRESS	34.04166	-118.26677	PC FOR A NEW SIGN LIGHTING, BULIDING PERMIT IS UNDER 19048-10000-02784	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46234	18041-20001-26137	1606 N LAUREL AVE	90046	4	147B177   535	5551016***	R3-1XL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	34.10031	-118.36414	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 38.08 kWdc/33.47 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (112) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46235	13041-20000-26329	21929 W VENTURA BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	PIN	34.16940578	-118.60503747	PC FOR T24 ENERGY ONLY. HAIR SALON. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46236	19041-10000-31738	1820 S 4TH AVE	90019	10	126B189   867	5072029016	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.20	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	12/08/2020 12:00:00 AM		Permit Finaled	04/19/2022 12:00:00 AM	ADDRESS	34.04039	-118.32107	Full plan check for power and energy total new connected load is over 400A. Scope of work includes 6 new panels, new circuits, and new lighting, the remaining electrical equipment is exisiting. Total affected area is 7267 sqft. B#19016-10000-25368	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46237	17041-20003-42726	7920 N MARQUAND AVE	91304	12	189B089   209	2020029049	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.21397	-118.64831	07/31/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta C. Battery back-up configuration has changed. 2/13/2018changes to an approved set of plans.  changes to include (2) tesla powerwalls.one tesla powerwall was charged under master application 17041-20000-42726(((pv1install roof mounted pv system sized 5.2kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46238	17041-10000-37406	5366 E ITHACA AVE	90032	14	139-5A235 180	5220017016	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Apartment			10/17/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.077	-118.1695	PC for one new FACP , annunciator panel and smoke detector. Fire alarm monitoring system pulled under 17041-10000-37369	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46239	19041-20000-41064	11881 W TERRA VISTA WAY #118	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46240	13041-10000-34177	1651 E MAURETANIA ST	90744	15	036B213   552	7425024044	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	33.79048	-118.24293	Plan check for T24. Remove HID light fixtures and replace with new fluorescent fixtures. Area 3060 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46241	15041-10001-03981	2939 S VINEYARD AVE	90016	10	120B181    97	5057016024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM			PC Approved	05/22/2015 12:00:00 AM	ADDRESS	34.02866	-118.34654	EXPEDITED RSES PLAN CHECK PER APLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46242	17041-10000-09507	8730 S EMERSON AVE	90045	11	096B165   903	4122013008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	33.95761	-118.40419	PC for energy only, outdoor only. Removing HID fixtures and replacing them with new LED ones. Area: 18,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46243	16041-10000-17783	4901 S MARIONWOOD DR	90230	11	108B161   250	4218002907	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	33.99325	-118.41076	NEW FIRE ALARM SYSTEM IN A-3 BUILDING. NEW FIRE ALARM PANEL WITH 33 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46244	11041-10000-25411	515 S FIGUEROA ST 10TH FL	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	REMODELING IN THE RESTROOMS, ELEVATOR LOBBY AND CORRIDORS OF AN OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46245	19041-10000-12840	12121 W WILSHIRE BLVD	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.04386	-118.46816	Plan check for power for (40) EV charging stations on existing 4000amp main switchboard. Total added new loads 468 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46246	17041-20000-42588	17130 W CLEMONS DR	91436	5	159B133   154	2292021010	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	02/24/2018 12:00:00 AM	ADDRESS	34.1329	-118.5053	pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46247	15041-10000-19310	5060 W VENICE BLVD	90019	10	126B181   134	5067002046	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.04502	-118.34932	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FIXTURES. TOTAL AREA 4532 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46248	19041-10001-04654	12645 W TIARA ST	91607	2	177B161   968	2341004016	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM			PC Approved	05/28/2019 12:00:00 AM	ADDRESS	34.17859	-118.4087	SUPPLEMENTAL FOR FEE EXPEDITE PLAN CHECK FOR 12.6KVA ROOF MOUNTED PV SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(SE7600H-US AND SE5000H-US) WITH 56 MODULES WITH P320 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46249	13041-10000-02649	3802 W REVERE AVE	90039	13	156A207   176	5435008001	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.12238	-118.26101	PHOTOVOLTAIC SYSTEM FOR SINGLE STORY SINGLE FAMILY DWELLING. PV1 SYSTEM TOTAL SIZE 2.16 KW. 10 UNITS. ENPHASE M215 MICROINVERTER. M215-60-2LL-S22. SOLAR PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46250	12041-10000-03633	2208 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM			PC Approved	02/16/2012 12:00:00 AM	ADDRESS	34.03793	-118.4408	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT. EXISTING PERMIT #11041-10000-25890	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46251	19041-20000-37205	22544 W JEFFREY MARK CT #3	91311	12	204B097    15	2724004***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.25591	-118.61825	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING HOUSE. SYSTEM SIZE IS 9.25 KW DC/7.6KW AC. SCOPE OF WORK CONSISTS OF (25) PV MODULES WITH OPTIMIZERS, AND A 7.6KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46252	12041-20001-03877	21318 W DUMETZ ROAD	91364	3	168B105   468	2172001026	C1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	07/09/2013 12:00:00 AM	ADDRESS	34.15749	-118.59513	((((6/25/2013: CHANGES MADE TO TITLE 24. TOTAL INDOOR SQRFT: 4973. TOTAL OUTDOOR SQRFT: 7360.))))Complete remodeling of the existing building A.  New 800A service, panels, and branch circuits.  Note: The only work at building B is replace outdoor lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46253	13041-10000-20337	610 S ST LOUIS ST	90023	14	126A221   122	5183023003	[Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Apartment			07/31/2013 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.03862	-118.21749	CHANGE OF USE FROM HISTORIC HOSPITAL TO SENIOR AFFORDABLE RESIDENTIAL UNITS, WITH 96 SENIOR AFFORDABLE UNITS, AND ONE MARKET RATE TWO BEDROOM UNIT, TOTAL OF 97 UNITS.  NEW 4000A SERVICE AND DISTRIBUTION SYSTEM.  POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46254	16041-10000-02801	3006 N NORTH COOLIDGE AVE	90039	13	150B213   905	5442022002	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.10419	-118.24468	TI on the kitchen of an (E) office building. Install new lighting fixtures, Total area: 362 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46255	15041-10000-05304	8712 S SAN PEDRO ST	90003	8	096A205    40	6041017011		South Los Angeles				2400.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.95882	-118.26933	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 13724 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46256	17041-20000-22221	700 S FLOWER ST 4th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for energy only. TI to corridors, elevator lobby, and restrooms on 4th floor of high rise building. New lighting (incl. emergency) - 1,355sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46257	14041-20001-01248	6108 N RESEDA BLVD	91335	3	177B125   614	2124008025	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.18103	-118.53581	][][ CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGES IS TO REFLECT ACTUAL LIGHTING INSTALLATION . PLAN CHECKING FOR T24 PART 6 ENERGY ONLY. CONNECTED LOAD IS LESS THAN 400A. APPROVED SET UNDER 14041-20000-01248 ][][]Change to lighting in an existing massage parlor.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46258	17041-10001-32362	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.01366	-118.28294	Replace Fire control panels along with 210 devices on LA Memorial Coliseum	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46259	15041-10000-03532	11350 W PENROSE ST	91352	6	192B173   280	2632006012	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.22354	-118.37891	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 31164 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46260	11041-20000-20309	5700 W WILSHIRE BLVD 675	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.06218	-118.35303	T.I.  Relocatind some light fixtures, adding new control, and emergency light modification.  Plan check is for energy and emergency lights.  Installing occupancy sensors and relocating luminaires.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46261	19041-10000-20647	1303 W ANAHEIM ST	90744	15	030B201   196	7416003019	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Closed	05/07/2021 12:00:00 AM	ADDRESS	33.77925	-118.2784	TI IN AN EISTING WAREHOUSE. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46262	13041-10000-28009	5857 S CENTRAL AVE # 170	90001	9	108B209  1588	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	pc for power and energy. FIRST TIME TENANT TO A CORE & SHELL COMMERCIAL BUILDING. 'WINGSTOP' RESTAURANT. FULL PLAN CHECK PER SUPERVISOR. TOTAL AREA TO BE 1740 SF. SIGN LIGHTING TO BE IN SCOPE OF WORK IN ADDITION TO GENERAL/DISPLAY LIGHTING FOR THE SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46263	13041-10001-19356	5857 S CENTRAL AVE #100	90001	9	108B209  1518	6007003902	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	CHANGES TO APPROVED SET OF PLANS. DELTA 5 CHANGES ONLY. MOVING LOADS FROM PANEL A  AND PANEL B AROUND. THE CHANGES HAVE BEEN CLOUDED. WATER HEATER SIZE HAS BEEN INCREASED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46264	18041-10001-25380	6150 N LAUREL CANYON BLVD BLDG A	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	Plan check only. Wet restamp and pereferate scanned copy of approved pereferated set to replace lost original set NEW FIRE ALARM SYSTEM TO A CORE AND SHELL RETAIL BULDING, (7) FA DEVICES AND (1) FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46265	16041-10000-15798	1760 E 22ND ST	90058	9	117A213    49	5167015047	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.01646	-118.2409	CHANGES OF USE TO WAREHOUSE AND OFFICE. PC FOR T24 ENERGY ONLY. RESUSE EXISTING DISTRIBUTION SYSTEM. NEW LIGHTING AND MINOR POWER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46266	18041-10000-42116	12208 W MARSHALL ST	90230	11	108B161   770	4221019031	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	33.99	-118.41667	PLANCHECK FOR Installation of a (N) 125A load center with (N) 5.8 kVA POWERWALL ENERGY STORAGE SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46267	14041-10000-27773	2645 S LA CIENEGA AVE	90034	10	123B173   670	5065007006	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.0335	-118.3785	PERMIT FEE IS DUE TO SENATE BILL 1222PV 2 system. Roof mounted. Negatively-grounded central-inverter system. 403 modules, 1 inverter, and 1 AC disconnect for a 102,765 kW system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46268	12041-20000-06411	11835 W OLYMPIC BLVD s.200E	90025	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	PIN	34.03318579	-118.45141815	s. 200E OFFICE T.I.Energy, emergencyFire/ Life safety is  BY OTHERS 12041-20000-06133	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46269	11041-10000-19763	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Info Complete	02/16/2012 12:00:00 AM	PIN	33.94363002	-118.42513364	New  HVAC equipment for Fedex Hangar bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46270	13041-10002-10352	14500 W SHERMAN CIR	91405	6	183B149   800	2219007034	(T)(Q)RAS3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			08/26/2015 12:00:00 AM			PC Approved	08/26/2015 12:00:00 AM	ADDRESS	34.19972	-118.44963	"DELTA ""A"" CHANGES TO PERMITTED SET OF PLANS: CHANGES TO LIGHTING SYSTEM IN THE GYMN AND  CLUBHOUSE; CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA""A""; LOAD INCREAS E FOR PANLS HC, HD,HJ AND NL. ((((((((((Plan check for new 284 appartment. NOT a methane hazard site. Fire Alarm Variance has been filed."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46271	15041-10000-34683	129 S KINGS ROAD	90048	5	138B173   707	5511015022	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.07355	-118.37236	fULL PLAN CHECK FOR 36 UNIT APT BUILING 4 - STORY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46272	19041-10000-04679	15470 W VISTA HAVEN PL	91403	4	159B145    66	2279018015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.13595	-118.46939	PV1. NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 11400H-US INVERTER AND (36) MODULES AND OPTIMIZERS (P400). SYSTEM SIZE IS 11.1KWAC AND 11.88KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46273	16041-20000-20060	2180 W CAMBRIDGE ST	90006	10	126B193   178	5074012003	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Apartment			06/08/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Expired	08/22/2018 12:00:00 AM	ADDRESS	34.04438	-118.30556	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46274	14041-10000-03532	624 S GRAND AVE	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/07/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	Add distribution equipment to relocate  loads to existing buswaysin commercial high-rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46275	13041-10000-25594	11332 W KINGSLAND ST	90066	11	117B157   120	4249004022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.02011	-118.42819	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 4 KW DC ON MICROINVERTER STANDARD PLAN IN A SINGLE-STORY HOME. (16) MODULES: TRINASOLAR TSM-250PA05.18(16) M215-60-240-52X  ENPHASE MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46276	19041-10001-24684	1411 W 190TH ST SUITE 250	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM			PC Approved	09/27/2019 12:00:00 AM	ADDRESS	33.85852	-118.30317	T-24 plan check,  TI. INSTALL: LIGHTING, RECEPTACLES to an existing tenant. No new circuits being installed. Total SQ FT: 2791 Permit fees paid under master application, Plan Check ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46277	10041-10000-20700	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	04/20/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	INSTALLATION OF TEMP POWERS  AND DISTRIBUTION BOARDS  AND ASSOCIATED EQUIPMENT IN THE CONSTRUCTION OF THE NORTH AND SOUTH CONCOURSES AT TBIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46278	12041-10000-08972	1130 N RAVOLI DR	90272	11	129B133   168	4425010030	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.05055	-118.50829	Plan check for new roof mounted photovoltaic system 18.48 KW and storage battery system (Sunny Islands) supplying optional stand-by loads. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46279	14041-10000-15493	888 S FIGUEROA ST	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.0465	-118.26225	Title 24 plan check only for existing highrise.  Total area = 6,180 sq. ft.Replace existing lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46280	15041-20000-16041	216 S ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			Corrections Issued	05/26/2015 12:00:00 AM	ADDRESS	34.04645	-118.23792	Addition of 3 strobes to existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46281	19041-10000-12903	610 S KINGSLEY DR #1	90005	10	135B193   914	5503025007	CR-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM			Corrections Issued	04/09/2019 12:00:00 AM	ADDRESS	34.06296	-118.30268	ENERGY PLAN CHECK FOR A CHANGE OF USE FROM CONVERTING AN (E)  PRE-SCHOOL DAYCARE TO ADULT DAYCARE WITH NEW LIGHTING AND EQUIPMENT. TOTAL AREA IS 4612 S.F.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46282	19041-20000-04292	20744 W CAMPANIA LANE	91326	12	213B109   394	2701068005	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.27975	-118.58542	Plan check for PV roof mounted system, system size: 9.9KW DC with 30 PV Modules and 1 inverter(10KW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46283	19041-20000-16699	22135 W ROSCOE BLVD LOT #42	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	pv1install roof mounted pv system sized 2.0KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46284	15041-20000-15275	1031 S GLENDON AVE	90024	5	132B153  1096	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.06193	-118.44439	Title 24 plan check only.  Total area = 4,490 sq. ft.  T.I. to existing commercial space.  CHange of use from retail to yoga studio.  Two new panels (<400 A new load).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46285	15041-10000-32357	624 S GRAND AVE 1st-Floors	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	PIN	34.04778206	-118.25563275	Energy plan check for a breakroom (kitchenette ) T.I located in the 1st floor of a high rise building. Scope includes new receptacles and lighting. Total area is 546-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46286	19041-10000-15198	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM			Reviewed by Supervisor	05/10/2019 12:00:00 AM	ADDRESS	33.78808	-118.29535	FULL PC POWER AND T-24 TO CHANGE OF USE TO MED OFFICE. INTERIOR TENANT IMPROVEMENT ON THE 4TH FLOOR. SCOPE OF WORK AREA IS  1,561SF.BUILDING PERMIT: 19016-10000-11612	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46287	19041-30000-14780	10000 W PICO BLVD	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.05211	-118.40654	Plan check for Title 24 only. Project site is a new single story accessory structure to an existing country club. Total lighting area = 830 sq. ft.Note: Building permit has been issued under 18010-10000-04633	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46288	13041-10002-27141	17544 W LANARK ST	91325	12	189B129   143	2201005009	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Expired	12/01/2015 12:00:00 AM	ADDRESS	34.21786	-118.51582	][][]  $0 permit fee is due to the 2012 Senate Bill No. 1222. CHANGES MADE TO AN APPROVED SET OF PLANS; DOWNSIZING MAIN BREAKER ][][][ORIGINAL DESCRIPTION::PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 4 kW. TRANSFORMERLESS INVERTER. TWO STORY.(16) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-3.6-OUTD-S-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46289	16041-10006-24464	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Closed	05/01/2019 12:00:00 AM	ADDRESS	34.09818	-118.35187	Changes to an approved set of plans. All changes are clouded under delta 17 only. Changes include relocating/replacing lighting fixtures, updated lighting floor plans, revising title 24 calculations, revising emergency photometrics, revising panel schedules, and adding/removing circuits and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46290	14041-10001-14934	631 N LAS LOMAS AVE	90272	11	129B121   857	4414014024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.04673	-118.53941	PV1, INSTALL 7.39 KW DC ROOF-MOUNTED SOLAR ARRAY ON 0NE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46291	16041-10001-40341	3120 S KELTON AVE	90034	5	120B157   171	4254007016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.02798	-118.42112	01/18/17Changes to an approved set of plans. Changes include using a different AC module from Sunpower. No change in AC output power(7.36kwac). All changes are made under delta A.Note: Permit is paid under PCIS#16041-10000-40341	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46292	14041-20000-19842	16938 W ENADIA WAY	91406	6	183B133   260	2227028007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.20001	-118.50264	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MAIN SERVICE PANEL.(19) TRINA SOLAR TSM-255 MODULES(1) POWERONE AURORA PVI4.2 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46293	14041-10000-00828	5620 N DENNY AVE	91601	2	174B177   441	2415019025	R2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Apartment			01/10/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.17277	-118.36472	PV2. SOLAR INSTALLATION OVER CARPARKING STRUCTURE. SYSTEM SIZE: 5KW DC.(20) TRINA SOLAR TSM-250(1) SMA SB4000 INVERTER(N) SUPPORT STRUCTURE ( 349 SF ) WITH INSTALLATION OF (1) PHOTOVOLTAIC SUPPORT STRUCTURE AND ELECTRICAL FOR PV INTERCONNECTION WITH CAISSONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46294	12041-10000-27023	6547 W FIREBRAND ST	90045	11	102B165   438	4110015031	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	33.97483	-118.40537	PV1 3.43 KW ROOF-MOUNT. ENPHASE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46295	14041-20001-03471	5187 N CHIMINEAS AVE	91356	3	171B125   398	2181006021	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.16533	-118.52821	Expedite Fee ONLY****New roof mounted PV system with 15.39 KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46296	12041-20001-08769	7405 W PYRAMID PL	90068	4	156B177   455	2427014026	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	PIN	34.1225914	-118.35630387	Change from previously approved plans.  Changes include AC non-fusible disconnect and rearrange modules on the roof.   The quantity of modules remain the same.Note: Permit issued under the 12041-20000-08769*****Install roof mounted PV system and change the service main circuit breaker to 150 amperes.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46297	15041-10000-17864	200 WORLD WAY TER 2/LV3-#241	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM			PC Info Complete	07/06/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER. FIRST TIME TENANT FOOD AND BEVERAGE KIOSK IN AIRPORT. TER 2 UNIT 241. PIE HOLE STORE. KIOSK IS USING SOFFIT LIGHTING FROM THE AIRPORT, EXEMPTED FROM TI-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46298	16041-20000-27037	11901 W SANTA MONICA BLVD Suite 209	90025	11	126B145   436	4263031034	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Issued	08/01/2016 12:00:00 AM	ADDRESS	34.04198	-118.46055	Plan check for energy only. TI for tanning salon. New lighting. 1,068sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46299	14041-20000-19738	1731 S FEDERAL AVE 1-25	90025	11	126B149   590	4262019024	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			07/22/2014 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.04169	-118.4517	New 5-story 25-unit apartment.  Variance to separate fire alarm plans filed 07/22/2014.COMPLY WITH DEPARTMENT ORDER effective date04/02/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46300	10041-10000-12970	3616 S TROUSDALE PKWY Room # 261	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	08/24/2010 12:00:00 AM	ADDRESS	34.01983	-118.28534	TI in an existing commercial area of the ALLEN HANCOCK building in Room # 261 of USC (Biological Research Center). Plan Check is for Title 24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46301	15041-10000-34620	1141 W 2ND ST	90012	1	133-5A209 224	5152009901	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.0588	-118.25625	Permit fee is $0.00 due to Senate Bill 1222. PV2 105 KW ROOFTOP TRANSFORMERLESS SYSTEM. 414 MODULES AND 3-INVERTERS CONNECTING THROUGH THE FEEDER SIDE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46302	16041-10000-14555	8506 N ROBERT AVE	91352	6	192B173   248	2408016021	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.22422	-118.36925	PV1, 5.886 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(18) MODULES: SUNPOWER SPR-327NE-WHT(1) INVERTER: SMA SB6000TL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46303	10041-10000-11267	9911 W WASHINGTON BLVD	90232	10	120B165  1311	4207004026	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	ADDRESS	34.02158	-118.39805	CHANGE OF USE FROM RETAIL TO RESTAURANT. PLAN CHECK FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46304	12041-10002-19122	928 N WESTERN AVE 1-49	90029	13	144B193  1345	5535020007	(Q)RAS3-1VL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Apartment			03/24/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.08731	-118.30896	CHANGES TO PERMITTED SET OF PLANS;NEW PANEL BOARDS AND CKTS AND OUTSIDE CANOPY PLAN CHECK FOR NEW 5 STORY MIXED USE APARTMENT BUILDING WITH  49 UNITS. FIRST LEVEL FUTURE COMMERCIAL RETAIL. NEW 2000A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46305	19041-20001-34233	3730 N WESTFALL DR	91436	5	162B137   459	2293006008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			Reviewed by Supervisor	09/13/2019 12:00:00 AM	ADDRESS	34.13857	-118.49393	PV1. expedited plan checl. Install 12.285 kW roof mounted and grid tied PV system and 27 kWh energy storage system.  (39) modules with 11.4 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46306	17041-30000-33637	1310 N TAMARIND AVE	90028	13	144B189    37	5545015060	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			09/19/2017 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	02/25/2021 12:00:00 AM	ADDRESS	34.09479	-118.3189	Plan check power and energy for new 32 units appartment building 4 story with 2000A service. Total area: 29,630 sq ft. B#16010-10000-03474 Fire alarm variance has not been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46307	15041-20000-30427	11512 W CLARKSON ROAD	90064	11	120B153   660	4258015026	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.02501	-118.4357	Installation of new roof mounted solar PV array on existing single family home.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46308	19041-10000-29722	750 E SLAUSON AVE	90011	9	108B205  1507	6007002032	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.98908	-118.26204	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46309	18041-10000-00962	1243 S OLIVE ST C119	90015	14	126A207   200	5139023038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Closed	11/28/2018 12:00:00 AM	ADDRESS	34.03859	-118.26331	PC FOR FIRST TIME TENANT FOR A DOG SPA (CHANGE OF USE FROM RETAIL TO DOG GROOMING AND CARE). THIS IS A HIGH- RISE BUILDING. SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 7531 SQ.FT .B#17016-10000-18903	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46310	14041-20000-06653	3415 S SEPULVEDA BLVD #150	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.02055	-118.42347	T.I. to a high rise building on the first floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46311	12041-10000-02286	9035 N RESEDA BLVD	91324	12	195B125    56	2770004006	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	05/18/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.23467	-118.53635	CONVERT 25'X77' PORTION OF (E) BAKERY RETAIL TO (N) RESTAURANT, INCL.  T. I.hours of operation:  7:00AM-11:00PM,   ( no alcohol beverages)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46312	16041-30000-15821	9200 N OAKDALE AVE 4th Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 23,285 sq. ft.Note: Building application has been created under 16016-10000-08907	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46313	13041-20000-02364	17000 W ESCALON DR PV-1	91436	5	162B133   170	2287003028	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2013 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.14039	-118.50239	PV-1. Plan check for PV SFD. 5 strings and 11.445 kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46314	13041-10001-13579	1381 W SUNSET BLVD	90026	1	138A211    26	5406012038	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	ADDRESS	34.07343	-118.25125	changes to approved set of plans (plan check for asbuilt): added lighting and changed type of lights.13041-10000-13579permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. RETAIL DOMINO'S PIZZA DELIVERY. less than 400A per applicant. 1story.CHANGE OF USE FROM RETAIL TO RESTAURANT. INTERIOR REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46315	13041-10000-27948	3185 E WASHINGTON BLVD	90023	14	117A223    39	5169020003	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.01526	-118.21058	][][ $0 permit fee due to 2012 senate bill, 1222 ][][]PV2 41.8KWdc. 480/277V. Transformerless, Ungrounded. NONstd. 3story. Roofmount. [(2) inverters: {SMA STP 20000TL-US}]. [(110)modules: {SolarBine SB-m380NA1}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46316	19041-20000-16140	20711 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.29322	-118.58514	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46317	18041-20000-05617	8607 N CANTALOUPE AVE	91402	6	192B153    66	2637032023	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.22645	-118.4366	PV1.  Install 6.6 kW roof mounted grid tied PV system.  (26) modules with (1) 6.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46318	19041-10000-48414	22855 W VICTORY BLVD	91307	12	180B097   327	2038040021	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM			Reviewed by Supervisor	12/05/2019 12:00:00 AM	ADDRESS	34.18859	-118.62711	"Replacing existing lights in an existing ""Home Depot"" with new lights. Affected area: 116,110 SFT (INDOOR) + 24,497 SFT (OUTDOOR)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46319	19041-10000-15420	522 S GLADYS AVE	90013	14	126A213    19	5147017022	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.04144	-118.24087	T-24 ENERGY ONLY PLAN CHECK IN A COMMERCIAL WAREHOUSE GENERAL LIGHTING. SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5185 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46320	19041-20000-42581	6320 N CANOGA AVE 1st Floor	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.18499	-118.59722	Paln check for Title 24 Energy only new lighting, existing circuits. Total area: 2300 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46321	12041-10000-18225	10246 N BIANCA AVE	91325	12	204B129   194	2734027001	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.25678	-118.51431	NEW 9.36 KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46322	19041-10000-42415	17200 W WEDDINGTON ST	91316	5	171B133   216	2258005015	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.1666	-118.50801	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 13.23KVA PV1 SYSTEM CONSISTING OF 42 MODULES USIGN MICROINVETERS(IQ7X) CONNECTED TO EXISTING 200A CENTER FEED PANEL. $50.19 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46323	13041-10000-05220	11175 W SANTA MONICA BLVD 4TH FLOOR	90025	5	129B149   297	4324035029	M1-2	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.04739	-118.44609	T24 FOR EXISTING OFFICE SPACE FOR BATHROOMS AND CORRIDOOR. 1432 SQRFEET. PERMIT TO  BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46324	14041-20001-34950	10454 N GLORY AVE	91042	7	204B201    96	2569024032	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM			PC Approved	01/08/2015 12:00:00 AM	ADDRESS	34.2591	-118.28074	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main breaker to 150A.System size: 11.18kW. Ungrounded system.52 EnPhase M215 microinverters with 52  275W pv modules across 5 strings (5+13+14+8+12). Combining string of 5 with string of 8.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46325	15041-20003-16156	7435 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.20582	-118.48615	03/04/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Revisions have been made to feeders, new equipment has been added, and breakers for GPUs have been downsized.*****Previous Work Description*****(2) NEW AIRPLANE HANGARS WITH AN ATTACHED 2-STORY OFFICE. NEW COMMERCIAL BUILDING TO THE VAN NUYS AIRPORT. FULL PC, PC FOR POWER AND ENERGY ONLY. 1600 SERVICE AND TOTAL SQ. FT. 67377. FEES PER APPLICANT, PRE MADE CHECK. NO TI-24FEES,  FEES NEED TO BE ADJUSTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46326	09041-20003-05355	9480 W READCREST DR	90210	4	147B165   347	4352010046	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.09824	-118.40466	Delta D plan check only. Changes from previously approved plan.  All changes are clouded as shown on plans (as-built).*****Plan check power for new electrical system with new 600A service, eeuipment, panels, and circuits for single family dwelling.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46327	17041-10000-28371	15557 W SATICOY ST	91406	6	189B141   255	2222005001	RA-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.20861	-118.47247	PC for T24 only for replacement of 12 outdoor existing fixtures with LED fixtures. Total area is 19600 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46328	17041-30000-19891	8459 W MELROSE PL	90069	5	141B173   422	5528001034	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM			PC Approved	06/13/2017 12:00:00 AM	ADDRESS	34.08374	-118.37513	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,494 sq. ft.Note: Building application has been generated under 17016-30000-12732	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46329	19041-20002-23125	1432 W 244TH ST	90710	15	039B193   269	7439018034	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	07/25/2019 12:00:00 AM	ADDRESS	33.80315	-118.30237	Revisions to approved set of plans - change of interconnection detail. $0 plan check fee per State Senate Bill SB 1222 and State Assembly BIll AB 1414.(((PV1, ROOF MOUNTED SOLAR SYSTEM USING (22) MICROINVERTERS. TOTAL SYSTEM SIZE IS 6.82 KWDC AND 5.5KWAC.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46330	13041-10001-25423	3051 S DANALDA DR	90064	5	123B165   139	4316015015	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM			Reviewed by Supervisor	09/24/2013 12:00:00 AM	ADDRESS	34.03642	-118.40378	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46331	17041-10000-35433	9143 N DE SOTO AVE	91311	12	198B109   160	2746009023	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	11/27/2019 12:00:00 AM		Issued	11/27/2019 12:00:00 AM	ADDRESS	34.23672	-118.58873	CHANGE OF USE FROM RETAIL TO FITNESS CENTER (8227 SF) TI, SCOPE OF WORK INCLUDES NEW SERVICE, LIGHTING AND RECEPTACLES. 120/208V, 3PH, 4W, 1600A. TOTAL SQ. FT. 34003	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46332	16041-10000-00730	717 W OLYMPIC BLVD STE 105	90015	14	127-5A207 342	5138002***	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.04503	-118.26348	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL STORE (T-MOBILE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AREA IS 1738 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46333	19041-20000-32396	2908 N ALLESANDRO ST	90039	13	150B213   870	5442024045	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/19/2019 12:00:00 AM	05/11/2021 12:00:00 AM		Permit Finaled	05/24/2023 12:00:00 AM	ADDRESS	34.10414	-118.24613	Full plan check for new apartment building. New 1200A 208Y/120V 3ph-4w service. New panels, lighting, and power loads. Plan check for power and energy. T24 included total square footage = 16063 sf	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46334	18041-20000-25238	8250 W FOOTHILL BLVD	91040	7	204B193   151	2560009049	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.25945	-118.31307	PV2.  Install 86.4kW AC roof mounted grid interactive PV system on commercial storage facility.  (288) modules and (6) 14.4 kW rated string inverters Solaredge SE 14.4KUS.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46335	13041-20000-28384	1232 S LA CIENEGA BLVD	90035	5	132B173  1104	5087003006	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.05473	-118.37596	PC FOR T24 ENERGY ONLY. FIRE DAMAGE BUILDING. ALL ELECTRICAL NEW PER APPLICANT. ONLY EXISTING IS SERVICE. LOAD LESS THAN 400A, EXISTING SERVICE, METHANE N/A NO NEW UNDERGROUND PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46336	11041-20000-18781	127 S SAN VICENTE BLVD Bulletin-101 t.i.	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 101 t.i.  plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46337	14041-20000-24103	1860 N FULLER AVE	90046	4	150B181   514	5572030029	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	Apartment			09/03/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.10507	-118.34882	TI TO AN EXISTING APARTMENT BULIDING TWO FLOORS.  ADDING LIGHTS AND NEW CIRCUITS TO EXISTING PANELS.  WORK TO BE DONE ON THE LOBBY FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46338	13041-20000-10363	18200 W SANDRINGHAM CT	91326	12	213B125   311	2870015026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	34.28068	-118.53056	8.1kw roofmounted PV System for an existing single family residence..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46339	15041-20000-18384	1519 S GRANVILLE AVE	90025	11	126B149   522	4262005003	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			06/12/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.04209	-118.45779	NEW 3 STORY APARTMENT OVER PARKING GARAGE. 9 UNITS TOTAL. FIRE ALARM VARIANCE HAS BEEN FILED. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46340	17041-20000-00112	1119 N HUDSON AVE	90038	13	144B185   668	5533011003	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.09129	-118.33254	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighting only.  total square footage 2507	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46341	18041-10000-32410	2880 W JAMES M. WOOD BLVD	90006	10	132B197   831	5077029027	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			08/24/2018 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	10/18/2021 12:00:00 AM	ADDRESS	34.05573	-118.29124	Full PC for a new New 6-story, 193 unit Apartment Building, 18,130 sqft ground story retail with on-grade and two levels of subterranean parking. Scope includes a new 4000A 480V/277V 3 phase 4 wire Service. B#18010-10000-02075	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46342	18041-10000-10931	11601 W WILSHIRE BLVD STE 350	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	PLAN CHECK FOR FOR TITLE 24 ONLY FOR TENANT IMPROVEMENT WORK ON APPROX. 3,298 SF OF THE TOTAL FLOOR AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46343	11041-10000-05624	5406 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM			PC Approved	03/22/2011 12:00:00 AM	ADDRESS	34.06208	-118.34665	REMODELING OF SUSHI RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46344	17041-10001-36230	954 N MEI LING WAY	90012	1	135A215   134	5414011025	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			Reviewed by Supervisor	10/16/2017 12:00:00 AM	ADDRESS	34.06549	-118.23752	PC for 5kW rooftop solar in commercial building. Installing new 5kW solar inverter with 20 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46345	14041-20001-20114	3300 W BERKELEY AVE	90026	13	144A205   207	5425002001	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			PC Approved	08/22/2014 12:00:00 AM	ADDRESS	34.0894	-118.27341	Modfications to approved set.  Change to point of interconnection from service panel for duplex to duplex unit subpanel.  $0 submittal fee is due to Senate Bill SB-1222.  (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.4KW INTERCONNECTED WITH MSP.(25) SOLAR WORLD SW250 MODULES(25) ENPHASE M215 MICROINVERTERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46346	19041-20000-03614	21650 W OXNARD ST #1410	91367	3	177B105    83	2146006042	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only in existing space office Tenant Improvement Total area: 2051 sq ft. B#19016-10000-01394	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46347	15041-20000-30471	2614 S CRENSHAW BLVD	90018	10	123B185   782	5051007003	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	PIN	34.03197582	-118.33468856	Title 24 plan check only.  Total area = 3,250 sq. ft.   T.I. to ground floor of existing two story office building.  New lighting only (receptacles to remain existing).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46348	19041-20000-28098	5161 N AMESTOY AVE	91316	5	171B133   350	2258008024	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	02/10/2020 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.16454	-118.50558	Install new 13.5 kWh energy storage system.  (E) PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46349	18041-10000-13865	19310 S PACIFIC GATEWAY DR	90502	15	057B197     9	7351031030	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	33.85616	-118.29473	PLAN CHECK FOR TITLE 24 ONLY FOR (N) 4737 SF COOLER ROOM IN (E) WAREHOUSE INTERIOR. TOTAL AFFECTED AREA = 4320 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46350	16041-20000-14933	12520 W STAGG ST	91605	2	189B161   890	2307001007	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.21199	-118.40619	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (24) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46351	16041-10001-13793	7050 N TOPANGA CANYON BLVD	91303	3	183B101   272	2138002038	P-1VL-RIO, [Q]C1.5-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	05/11/2017 12:00:00 AM	ADDRESS	34.19875	-118.60563	Changes to an approved set; revised single line diagram. Downsizing service from 600 to 400 amps. Changes under delta C. Title 24 remained the same. (((PC for outdoor lighting only. . Total affected area: 973)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46352	14041-20000-34333	1156 N AMALFI DR	90272	11	129B133   167	4425012006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Expired	01/30/2017 12:00:00 AM	ADDRESS	34.05052	-118.50683	PV1. INSTALLING ROOF MOUNTED. 6.37 AC KW SYSTEM SIZE. (20) SUNPOWER SPR-X21-345(1) SMA SB70000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46353	19041-10000-00462	6703 N VALJEAN AVE	91406	6	180B137   117	2233031041	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	06/02/2021 12:00:00 AM		Permit Finaled	07/05/2023 12:00:00 AM	ADDRESS	34.19205	-118.4861	PLAN CHECK FOR POWER AND ENERGY FOR OFFICE T.I. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING SINGLE STORY BUILDING . TOTAL EFFECTED AREA 19945 SQFT NEW TOTAL CONNECTED LOAD OVER 400AMPSLD# 18014-30000-07105	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46354	18041-20000-19095	846 N ALTA VISTA BLVD	90046	5	141B181    55	5525002033	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.08657	-118.34731	Plan check for power and energy. Project site is a 3-story, 6-unit apartment building. Work includes a 600-amp service and a total lighting area of 5,768 sq. ft.Note: Building permit has been issued under 16010-40000-01782	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46355	16041-10001-12348	505 S VIRGIL AVE #305	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	34.0649	-118.28724	04/11/16Changes to an approved set. Changes inlcude adding (2'x 2' ) LED fixtures and removing LED tape lights from office space.Note: Original application under PCIS#16041-10000-12348 ((((((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE SUITE 305. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR SUITE 305. TOTAL AFFECTED AREA IS 1175 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46356	19041-20000-32159	11420 W OXNARD ST 1-8	91606	2	177B169   809	2338011017	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			08/16/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.17923	-118.37988	Plan check for 600A Service upgarde. Scope of work includes panels and equipments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46357	13041-10000-20995	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	33.94248	-118.40461	13041-10000-20995permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. INSTALL 2 LED ILLUMINATED SIGNS inside LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46358	11041-20000-02050	16921 W PARTHENIA ST 1st Floor	91343	12	195B133   420	2688041014	CR-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/02/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	ADDRESS	34.22863	-118.5009	PLAN CHECK POWER AND ENERGY FOR OFFICE TENANT IMPROVEMENT ON FIRST FLOOR. EXISTING 1600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46359	13041-20000-06966	6430 W SUNSET BLVD	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.09782	-118.32979	Plan check for energy and emergency lighting. 2nd floor. INSERT STUDIOS CNN. Commercial high-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46360	12041-10000-15827	17301 W CITRONIA ST	91325	12	201B133   480	2755008023	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.24578	-118.51164	Plan check for roof mounted installation of 10.7KW photovoltaic system. Single family dwelling.  Plan check is only for PV System.  Service upgrade is not plan checked.  All permit fees are under Inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46361	19041-30000-18143	231 W VERNON AVE	90037	9	112-5A203  33	5111010036	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.00394	-118.27727	Plan check for a PV carport system. PV System size is 150.015 kW DC, 137.845KW AC-CEC and consists of (4) inverters, (414) modules, and (1) load center.Fees $0.00 Due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46362	18041-10000-08941	11541 W COOLIDGE PL	90066	11	117B153   175	4250017026	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.0198	-118.43296	PV 1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND TESLA BATTERIES. (46) MODULES, (2)  6.6, 3.8 INVERTERS, AND NEW LOAD CENTERS. TOTAL PV SYSTEM SIZE IS 11.895 KWDC/10.4KWAC AND BATTERY SYSTEM SIZE IS 11.6KW/ 27KWH	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46363	15041-20000-37167	1123 N BRONSON AVE	90038	13	144B189   553	5534010008	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.09143	-118.31808	PC FOR POWER AND ENERGY. SCOPE INCLUDES ADDING 400A SINGLE PHASE SERVICE AND ADDING NEW LIGHTING TO AN EXISTING COMMERCIAL BUILDING (GYM/EXERCISE SPACE). TOTAL AREA IS 11323 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46364	16041-20001-21138	8950 N GLENOAKS BLVD	91352	6	195B173   149	2408005031	(Q)M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM			PC Approved	06/28/2017 12:00:00 AM	ADDRESS	34.2319	-118.36828	Revisions to approved set of plans.  Change to emergency system layout, feeder ratings, and subpanel locations.  Delta-3 revisions only.  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 10,390 sq. ft.Note: Building application has been generated under 16014-20000-02717)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46365	18041-10000-24713	18631 W SHERMAN WAY	91335	3	183B121   103	2118026012	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.20129	-118.53995	TITLE 24 ONLY FOR THE REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46366	12041-10005-29913	12760 W MILLENNIUM BLDG A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			05/05/2015 12:00:00 AM			Not Ready to Issue	05/05/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	(((5/5/2015- CHANGES MADE TO APPROVED SET. ADDING ONE SEWAGE EJECTOR)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46367	11041-10000-21441	6291 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.18382	-118.60178	INSTALL A NEW ELEVATOR RECALL SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46368	12041-10001-10650	2970 W OLYMPIC BLVD #305	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	Delta 2 Revisions. Revisions to T24 calculations, lighting, power, and suite has no patient care area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46369	18041-10000-07379	14111 W RIVERSIDE DR	91423	4	168B153   407	2248024015	[Q]C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	33.9787	-118.31759	PC for T24 only for replacement of indoor-outdoor existing fixtures with LED fixtures for Chase bank. Total area Indoor  is 19339sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46370	15041-10000-37401	4950 W SUNSET BLVD FLR 1-6	90027	13	147B197   813	5543022015	RD2-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.09786	-118.29745	TI TO AN EXISTING COMMERCIAL BUILDING.  REPLACING EXISTING FIXTURES WITH LEDS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOATGE 2330.  SCOPE OF WORK TO BE PERFORMED IN FLOORS 1 THRU 6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46371	15041-20001-38781	24625 W STAGG ST	91304	12	189B089   312	2017027038	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	ADDRESS	34.2122	-118.65701	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE : 17.658 KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46372	15041-20001-18715	6226 N SHIRLEY AVE	91335	3	177B117   291	2131019012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2015 12:00:00 AM			PC Approved	06/21/2015 12:00:00 AM	ADDRESS	34.18366	-118.55709	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 5.5 kWac.  Microinverter system with two branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46373	13041-20000-08276	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/01/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	Full plan check. Affected load is over 400A at 208V 3 phase. Low rise commercial. Microsoft. Fire Alarm Variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46374	13041-20000-21443	4607 N WOLFE WAY	91364	3	168A109   152	2172014062	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.15368	-118.58902	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0 KW. 23 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46375	16041-10000-42244	6171 W CENTURY BLVD # 120	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	33.9457	-118.39324	PC FOR ENERGY. T.I. AND CHANGE OF USE FROM OFFICE TO RESTAURANT . CONNECTED LOAD<400A. TOTAL AREA  1341 SQ FT.B # 160116-10000-22447	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46376	19041-10000-19715	5975 N SHOUP AVE	91367	3	177B101   160	2040041008	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Issued	10/25/2019 12:00:00 AM	ADDRESS	34.17892	-118.61491	FULL PLAN CHECK FOR SCHOOL TENANT IMPROVEMENT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 14400 SQ.FTBUILDING # 8Note. one of the five application under the same plan (4/5).B#19016-10000-15468	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46377	16041-20000-30901	11415 N PORTER RANCH DR	91326	12	213B113   325	2701072004	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.27858	-118.57253	TI TO AN EXISITNG COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 429.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46378	15041-20001-30757	20801 W VENTURA BLVD	91364	3	171B109    62	2166033045	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	34.16663	-118.58589	Changes made to approved set.  Changes made to panel schedules to reflect site conditions/scope of work.  Delta 5 changes only.   (((Title 24 plan check only.  Total area = 98,050 sq. ft.     T.I. to sales floor area of existing target.  Most lighting is to remain existing.  Total new load is less than 400 A.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46379	15041-20002-24184	8842 W FOOTHILL BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.26086	-118.32514	8.2.2017 - Plan check for modification to approved set. Changing from two services to a single 2000A service. Relocating service equipment outdoors. Revise some distribution. Add lighting to tower - update outdoor T24 compliance forms. Add exhaust fans. Layout of rooftop units rearranged. Delta 1 changes.=======Plan check for power and Title-24 (energy).  Total area = 5,249 sq. ft. (indoor) + 1,000 sq. ft. (outdoor)  Core and shell work on existing commercial space.  Two new 480V 3ph-3w services (ungrounded system), new distribution panels, and associated subpanels.  New lighting, HVAC, and other misc loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46380	19041-20000-52392	226 N BERENDO ST	90004	13	138B197   505	5518026006	R3-1	Central	Wilshire	Wilshire Center-Koreatown		2112.02	Electrical	Electrical	Apartment			12/18/2019 12:00:00 AM	05/12/2021 12:00:00 AM		Issued	05/12/2021 12:00:00 AM	ADDRESS	34.07534	-118.29403	800A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46381	10041-20002-20464	11540 N SEPULVEDA BLVD	91345	7	213B145     9	2664006***	A2-1, RE20-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	34.27973	-118.4687	2nd revision to approved plans	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46382	16041-20000-30651	11400 N FENTON AVE	91342	7	213B169   880	2530033012	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Expired	10/10/2018 12:00:00 AM	ADDRESS	34.27697	-118.3859	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.36 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46383	18041-20000-44200	2227 N OUTPOST DR	90068	4	153B181   319	5572008012	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.11277	-118.34479	PV1.  Install 19.215 kW roof mounted grid tied PV system.  (61) modules with 11.4 and 3.8 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46384	15041-10000-20461	6775 W SANTA MONICA BLVD	90038	4	144B185   685	5532020028	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.09088	-118.33805	PC FOR TITLE 24 ONLY. CHANGE OF USE FROM OFFICE TO BEAUTY SALON. TOTAL AREA 748 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46385	18041-20000-24084	6333 W 3RD ST 706	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.07157	-118.36014	Plan check for Title 24 Energy only in existing restaurant T.I. new lighting and receptacles. Total area: 3578 sq ft.B#18046-30000-01543	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46386	16041-20000-43916	3463 N GREEN VISTA DR	91436	5	159B133   115	2287009051	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.13375	-118.49865	PV1.  Install 7.7 kW roof mounted grid tied PV system.  (24) modules with (1) 7.7 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46387	13041-20001-16561	14061 W SAYRE ST PV1	91342	7	222B153   327	2508004005	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.30463	-118.44016	(((SUPPLEMENTAL APPLICATION FOR PC FOR CHANGE IN INVERTER. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. PC AND PERMIT UNDER THIS APPLICATION. ))))INSTALL ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM (3.185KW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46388	16041-30001-35001	5757 W CENTURY BLVD 415-425	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	33.9457	-118.38274	02/09/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1 and Delta 2. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance forms.*****Previous Work Description*****Title 24 plan check.  T.I. to combine existing 2 suites(# 415 & # 425) in one.  New lighting, receptacles, and one new subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46389	17041-10001-04843	6150 N CARPENTER AVE	91606	2	177B169   416	2334012037	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.1828	-118.39092	02-22-2017 Changes to an approved set of plan. Changes include relocate Service panel, AC disconnect and solar load center. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46390	19041-10000-53648	5371 W WILSHIRE BLVD	90036	4	135B181   908	5508008027	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.06242	-118.34587	TITLE 24 PLAN CHECK ONLY. SCOPE OF WORK INCLUDES ADDITIONAL LIGHTING FIXTURES TO AN EXISTING SPACE AND RELOCATION OF EXISTING CIRCUITS. TOTAL AFFECTED AREA: 2950 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46391	16041-10000-38348	227 E PICO BLVD	90015	14	124-5A209 133	5145028009	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.03542	-118.25854	PC FOR ENERGY. CHANGE OF USE RETAIL SHOP TO RESTAURANT. SCOPE OF ENERGY WORK 1798 SQ FT. LOAD ADDITION <400A. B# 16016-10000-24994	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46392	13041-20001-22367	24440 W INDIAN HILL LANE	91307	12	186B089   477	2031013061	RE20-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	34.20511	-118.65548	((expedite fees)) PV1 CENTRAL INVERTER. 33 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46393	13041-10001-34509	7118 N BURNET AVE	91405	6	183B145   135	2220004180	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Verifications in Progress	03/06/2014 12:00:00 AM	ADDRESS	34.19992	-118.46212	Expedited RSES plan check per applicant request.{{PV1, Install a 4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46394	17041-10001-43250	222 S MAIN ST	90012	14	130-5A213 144	5161026040	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	34.05047	-118.2448	PC for T24 only for new lighting in retail TI. Installing new 100A panel, new lights and receptacles. Total area is 1171sqft. Permt fees are under master permit under 17041-10000-43250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46395	13041-10000-27868	5017 W AMBROSE AVE	90027	4	150B197   307	5589011025	RE9-1	Central	Hollywood	Greater Griffith Park		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.10894	-118.29864	PV1 Plan check for new roof mounted 3KW DC Photovoltaic system for Transformerless inverter with {SOLAREDGE SE3000A-US}]. [(12)modules: {Trina {TSM-250PA05.08}}] with power optimizers. PV interconnection shall be made at opposite end of main circuit breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46396	15041-10000-06215	11565 N DRONFIELD AVE	91331	7	213B161   595	2532005013	A2-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.27978	-118.40675	PV1.  Install 4.251 kW roof-mounted, utility-interactive PV system.  PV standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46397	19041-10000-03968	2806 S ELLENDALE PL	90007	9	123B197  1598	5055012003	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.02933	-118.28859	Plan check for PV1 7.6KW AC roofmounted system with (21) module and (1) inverter interconnecting through the main panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46398	16041-20000-15167	8001 N VENTURA CANYON AVE	91402	6	189B157   306	2213019040	(T)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.21649	-118.42885	PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORT.  241, 983 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46399	19041-10000-13078	609 N HIGHTREE ROAD	90402	11	126B129   813	4409025003	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/29/2021 12:00:00 AM	ADDRESS	34.03825	-118.51663	PV1 system with a battery backup unit. Scope  includes 24 units and 1 inverter. New 200A service interconnecting to a subpanel. System size is 8.04KWdc, 6KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46400	12041-10000-21379	23759 W DEL CERRO CIR	91304	3	186B093   225	2027016018	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.20689	-118.64352	roof installatin of a photovoltaic system with microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46401	16041-20002-37480	19230 W HATTERAS ST	91356	3	174B117   125	2156005002	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.17566	-118.55285	RE-PLANCHECK DUE TO LOST PLANS. PLANCHECK ONLY. PERMIT UNDER 16041-20000-37480pv1install roof mounted pv system sized 13.8kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46402	18041-10000-21655	3131 W OLYMPIC BLVD	90006	10	129B193   271	5080024027	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM			PC Info Complete	06/11/2018 12:00:00 AM	ADDRESS	34.05277	-118.304	PLANCHECK FOR T24 ENERGY. TI ON AN (E) COMMERCIAL SPACE USED AS A RESTAURANT WITH 36 SEATS. TOTAL AREA UNDER THE SOW: 1,036 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46403	15041-10000-36565	7525 S BROADWAY	90003	9	099B201    49	6031010019	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM			PC Info Complete	11/05/2015 12:00:00 AM	ADDRESS	33.97113	-118.27849	T-24. PC FOR ENERGY ONLY. TI ON EXISTING RESIDENTIAL DUPLEX BUILDING. SCOPE INCLUDES CONVERTING PART OF A DUPLEX INTO AN OFFICE SPACE AND ADDING NEW LIGHTING. TOTAL AREA IS 500 SQ. FT.PLAN SET LOST. REFER TO SUPPLEMENTAL FOR NEW APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46404	17041-10004-37515	1400 N CAHUENGA BLVD	90028	13	147A187   280	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM			Reviewed by Supervisor	10/18/2018 12:00:00 AM	ADDRESS	34.09641	-118.32933	**** NOTE: PLAN CHECK HAS BEEN PERFORMED UNDER 17041-10005-37515 / E18LA04685. INSPECTION FEES TO BE PAID UNDER 17041-10005-37515 / E18LA04685PLAN CHECK ONLY.DELTA 5 CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDING 1 (400A) PANELS WITH 10 EV CHARGERS -  AFFECTING PANEL SCHEDULES, LAYOUT AND LOAD CALCULATIONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46405	11041-20000-01595	15760 W VENTURA BLVD 14th FL	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check T24 Energy (general/emergency) lighting on the 14th FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46406	14041-20000-34437	601 S FIGUEROA ST 37TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.05076	-118.25881	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO OFFICES AND NEW CIRCUITS TO EXISTING PANELS.  WORK TO BE PERFORMED IN THE 37TH FLOOR.  TOTAL SQUARE FOOTAGE 4190.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46407	16041-20000-13522	8336 W BEVERLY BLVD	90048	5	138B173   475	5511010005	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.0759	-118.37138	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Existing panels and 1 circuit for the new lighting fixtures. Total lighting area = 1,307 sq. ft. Note: Building permit has been pulled under 16016-10000-02778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46408	15041-10002-39546	23749 S PRESIDENT AVE	90710	15	042B193   554	7439004011	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	33.81007	-118.30407	04/18/16Changes to an approved set of plans. Changes include relocating the ABB #PVI-3.6 inverter on the roof-layout to adjacent of the AC disconnect.NOTE: Permit pulled PCIS#15041-90000-39546 (((((([PC only] rooftop solar installation 3.6kW system.(19) KU2656ZPA(1) PVI-3.6-OUTD-SPermit under 15041-90000-39546	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46409	12041-10000-07386	958 E 52ND ST	90011	9	108B209   111	5103026031	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM			PC Approved	06/15/2012 12:00:00 AM	ADDRESS	33.99572	-118.25885	TI IN AN EXISTING CHURCH.  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46410	16041-20000-02260	13090 N BORDEN AVE	91342	7	222B153    25	2504016046	RA-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			Reviewed by Supervisor	02/03/2016 12:00:00 AM	ADDRESS	34.30817	-118.44386	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (76) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46411	11041-10000-16732	250 W 5TH ST	90731	15	018B201   823	7455019923	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	33.74004	-118.28238	TI TO THE 2ND FLOOR OF AN EXISTING PRIVATE SCHOOL, WITH NO LOAD CHANGE PER THE APPLICANT.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46412	14041-20000-25284	13940 N BREGER AVE	91342	7	231B157   361	2582011043	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.32619	-118.43027	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(25) CANADIAN SOLAR MODULES CS6P (1) SOLAR EDGE 5000 TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46413	19041-10000-05503	12524 W CORRENTI ST	91331	7	204B161   591	2537012009	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.25368	-118.40643	Plan check for a 7.6 kW AC / 8.96 KW DC roofmounted PV1 system with (1) inverter, (32) modules and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46414	11041-10000-16037	4501 W COLORADO BLVD B1	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.14246	-118.2705	PARTIAL RENOVATION AND PARTIAL DEMOLITION OF ONE-STORY EXISTING BUILDING #1. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46415	15041-20000-42515	5253 N VINCENT AVE	90041	14	163-5A225 125	5669018015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	03/05/2016 12:00:00 AM	ADDRESS	34.14295	-118.2025	PV1, rooftop solar installation interconnect with 200A MSP(17) LG300N1K-G4(1) ABB PVI-4.2-OUTD-S-US-Astandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46416	15041-10000-09906	600 WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	04/03/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	ALTERATIONS IN OFFICE SPACES AT THE ALSKA AIRLINES OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46417	14041-10000-04146	5372 E TEMPLETON ST	90032	14	142-5A237 174	5219015016	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			Reviewed by Supervisor	03/06/2014 12:00:00 AM	ADDRESS	34.08492	-118.16613	PV1, Install 3.25 kW DC roof-mounted solar array on a two-story home, interconnect with existing service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (13) Modules: CANADIAN SOLAR CS6P-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46418	11041-20000-11831	555 W 5TH ST 15th Floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I. on the 15th Floor of a high rise building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46419	13041-10000-09317	4030 S WESTERN AVE	90062	8	114B193   331	5021008030	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.01061	-118.30872	FULL PLAN CHECK POWER AND ENERGY FOR EXISTING SPACE (RALPHS) TO BE SUBDIVIDED FOR THREE NEW TENANTS. 600A SERVICE. 25543 sqrft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46420	16041-20000-21834	21820 W BURBANK BLVD STE 205	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.17228	-118.6032	TI TO AN EXISTING COMMERCIAL BUILDING TWO STRORY.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FPOR ENERGY AND EMERGENGY LIGHITNG.  TOTAL SQUARE FOOTAGE 2290. SCOPE IN SUITE 205	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46421	10041-10000-16925	101 S ROBERTSON BLVD #211	90048	5	138B169   372	4334001028	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.07513	-118.38391	TI in an existing office area on the second floor in suite #211. Plan Check is for T-24 energy calcs and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46422	18041-10000-09074	5589 W 82ND ST	90045	11	099B173   732	4127021002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Expired	03/05/2024 12:00:00 AM	ADDRESS	33.9641	-118.37829	Plan check for a utility own residential PV 2kw AC roof mounted system with (7) modules and microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46423	15041-10000-07562	2121 S AVENUE OF THE STARS SUITE 2100	90067	5	150A217   163	5456016002	C2-2-O, R2-1	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.05554	-118.41342	TI FOR AN EXISTING HIGH RISE COMMERCIAL BUILDING. ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. SCOPE OF WORK TO BE PERFORMED IN SUITE 2100 TOTAL SQ. FT. 2762.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46424	12041-10000-03571	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Apartment			02/16/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	PIN	34.12750533	-118.21285206	Renovation of an existing dormitory.  Change to lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46425	13041-10000-29072	12151 N SAN FERNANDO ROAD	91342	7	216B149   236	2611010005	C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.29057	-118.44992	NEW FIRE ALARM SYSTEM FOR A SINGLE STORY DIALYSIS BUILDING. NEW 1-STORY TYPE III-A MEDICAL CLINIC ( MEDICAL CLINICS WITH CHRONIC, NOT PLAN-REVIEWED FOR OSHPD III REQUIREMENTS) PER BUILDING PERMIT 12010-20000-01834. CLINIC IS NOT LICENSED PER APPLICANT. 71 DEVICES WITH 1 FIRE ALARM CONTROL PANEL. TOTAL AREA IS 9485 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46426	13041-10000-02471	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	33.94248	-118.40461	This is atemp power  fed from an existing switch gear intented to use for construction in terminal 5 delta air line.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46427	15041-10000-20867	212 N AVENUE 57	90042	1	151-5A229  69	5468033037	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Expired	10/23/2017 12:00:00 AM	ADDRESS	34.11097	-118.19401	PV1.  Install 3.27 kW roof-mounted, utility-interactive PV system.  Plan check per applicant request.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46428	19041-20000-47718	13263 N WHEELER AVE UNIT 8	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46429	18041-20000-40871	17158 W PARTHENIA ST	91325	12	195B133   458	2690015046	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.22839	-118.50776	Plan check for PV roof mounted system, System size: 10.8KW DC, 8.96KW AC with 30 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46430	17041-10000-32468	12760 W OSBORNE ST	91331	7	204B161   652	2624001900	PF-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.25297	-118.41083	PC for new fire alarm system in two story Police station with basement. PC for 189 devices, once FACP panel, one annunciator and two BPS panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46431	19041-10000-42204	426 S OXFORD AVE	90020	10	135B193   529	5503013006	R3-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.06629	-118.30766	New roof mouted PV1 solar system. System size: 6.51kW DC/ 6000 AC; Number Modules: 21; Central Inverter Model SE6000H interconntecing through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46432	13041-10000-35064	1801 S FIGUEROA ST	90015	9	124-5A205 282	5126002009	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.03524	-118.27179	PLAN CHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION AND REMODELING OF VEHICLE SERVICE FACILITY; PARTS STORAGE AND OFFICES AND THREE LEVELS OF PARKING AND A ROOFTOP PARKING DECKBUILDING PC # 13010-10000-04076	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46433	10041-10000-17595	1257 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.05123	-118.22581	Solar voltaic system installed on the roof of the building.  Consists of 18 modules,  18 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46434	13041-10001-00977	380 WORLD WAY Space T34	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI 1ST TENANT FOR TOM BRADLEY TERMINAL. THE LARDER AT TAVERNPROPOSED 1813 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE  CONCESSION (The Larder at  Tavern).Addition of a brkr disconnect on the secondary of 75 kva xfmr.   9-12-13	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46435	19041-20000-53224	1059 S MANHATTAN PL	90019	10	129B193   591	5080002011	R1-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM	03/12/2020 12:00:00 AM		Issued	03/12/2020 12:00:00 AM	ADDRESS	34.05108	-118.3103	$0 fee per Ab1414PV2, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INERTER. (150) MODULES AND (3) 11.4 KW SOLAREDGE INVERTERS. TOTAL SYSTEM SIZE IS 51.75 KWDC / 34.2 KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46436	13041-10000-16885	2910 N SAN FERNANDO ROAD	90065	1	153A213   165	5457004007	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	PIN	34.11219611	-118.24412502	Power and lighting for new cell tower.  Newly connected load < 400 A, title 24 plan check only.  Interior and exterior lighting.  Externally illuminated sign (building approval obtained).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46437	13041-10001-18143	11750 S JEFFERSON BLVD	90230	11	105B165   218	4220015033	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	PIN	33.98626775	-118.40053173	CHANGES TO APPROVED (delta 11): ADDITION OF contech PUMP and step up transformer to serve it. Plan check for power only. sheets ES-1,2.2,3.2,3.4 have been modified. Changes on plan show lockable disconnect for transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46438	14041-10000-31598	12307 W 6TH HELENA DR	90049	11	129B141    10	4405040007	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM			PC Approved	03/23/2015 12:00:00 AM	ADDRESS	34.05367	-118.47844	Power plan check for a new  2-story single family residence construction. Service equipment is 600 Amp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46439	16041-20000-07883	7922 N HASKELL AVE	91406	6	189B141   117	2206001009	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.21463	-118.47476	Install a roof mounted solar array on a Commercial building. Interconnect with a 600A MSP.System size: 20kW. (64) 315W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46440	13041-10000-10852	5433 N ROYER AVE	91367	3	174B097   915	2042007039	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.16927	-118.62786	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 13.44KW. USING 10 KW INVERTER. USING STANDARD PLAN TRANSFORMED INVERTER. 56 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46441	14041-20000-20053	19731 W MARIPOSA CREEK WAY	91326	12	213B113   129	2701028043	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.28254	-118.5657	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(21) Trina Solar TSM-255PA05.18 pv modules(21) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46442	18041-20001-04239	17259 W DEVONSHIRE ST	91325	12	204B133   166	2695015001	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	34.25773	-118.51007	expeditepv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46443	18041-10000-42824	700 S MAIN ST	90014	14	127-5A211 142	5145001003	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	01/23/2024 12:00:00 AM	ADDRESS	34.04365	-118.25151	***50% PDPP submittal for Zoning, partial Life&Safety, Partial structural Basis of Design only*** CHANGE OF USE FROM (E) RETAIL, ACCESSORY OFFICE/STORAGE TO RETAIL, ASSEMBLY, AND OFFICE. (CORE & SHELL) (E) 4 STORY WITH BASEMENT URM BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46444	14041-10001-07253	12521 N NEDRA DR	91344	12	219B133   320	2609022027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	ADDRESS	34.2978	-118.49962	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46445	12041-20000-27347	1026 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/21/2012 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	PIN	34.02400284	-118.2895744	New construction and rennovation for a commercial building.  Full Plan check.  Site is in a Methane Zone, Level 1 with less than 2 inches (Passive system only).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46446	13041-20000-01013	10880 W WILSHIRE BLVD STE 1101	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM			PC Approved	01/15/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check for energy and emergency lighting. Suite 1101.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46447	17041-10002-04025	310 N MADISON AVE	90004	13	138B197   243	5501002034	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.0768	-118.28902	CHANGES TO AN APPROVED SET OF PLANS. SCOPE OF WORK UNDER DELTA 4 AND  INCLUDES CHANGES TO  LUMINAIRE TYPE A, B AND C. TITLE 24 CALCULATION REVISED TO REFLECTED THE CHANGE. PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46448	18041-20000-19456	17516 W VINTAGE ST	91325	12	204B129   534	2734019010	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.25197	-118.51631	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (29) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46449	12041-10000-04896	1781 E 1ST ST Ground-level	90033	14	129A221   187	5174024041	R3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	ADDRESS	34.04739	-118.22035	TI in the ground level of 51 units appartment BLDG. EPC is for Energy & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46450	15041-10004-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			Corrections Issued	03/30/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	PC FOR CHANGE TO APPROVED SET OF PLANS. CHANGE CLOUDED. ATS AIC RATING UPDATED ON PLANS TO SHOW PER AS BUILT. RECHECKING FOR NEW AIC AND ISC VALUE. UPDATED ENGINEER ON JOB	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46451	17041-10000-29896	5405 S JANDY PL	90066	11	105B161   931	4211006012	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			Reviewed by Supervisor	08/29/2017 12:00:00 AM	ADDRESS	33.98147	-118.41672	PLAN CHECK FOR POWER AND ENERGY FOR - NEW 6 STORY PARKING GARAGE (415 STALLS) POST TENSIONED SLAB - SCOPE INCLUDES 3000A SERVICE FEEDING BOTH PARKING GARAGE AND EXISTING BUILDING. TOTAL AFFECTED AREA = 115,551 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46452	17041-30000-09048	601 S FIGUEROA ST Suite 1400	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 9,265 sq. ft.Note: Building application has been generated under 17016-10000-05779	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46453	10041-10000-09333	10701 W PICO BLVD	90064	5	126B157   691	4320005064	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Issued	05/18/2010 12:00:00 AM	ADDRESS	34.04183	-118.42538	Replace existing outdoor lighting with new LED fixtures. Plan Check is for T-24 energy calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46454	16041-20000-21942	7935 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.21495	-118.53492	PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46455	15041-20000-15233	6250 N TOPANGA CANYON BLVD #1590	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check 1st time tenant for Sugar Nail. Total area: 1,522 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46456	16041-10000-29244	123 S ASTRONAUT ELLISON S ONIZUKA ST #101-C	90012	14	130-5A213 128	5161016028	[Q]C4-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	12/03/2016 12:00:00 AM	ADDRESS	34.05019	-118.24211	PC FOR TI. TILTLE 24 FOR RESTAURANT. TOTAL AREA OF 828 SQ.FTSCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46457	12041-20000-17467	3200 N SAN FERNANDO ROAD bldgA	90065	13	153B209   457	5458002005	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	PIN	34.11584034	-118.25003258	Change of use from office to professional school (BUILDING A - WEST BLD).  Add branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46458	14041-10004-15434	3640 W WILSHIRE BLVD	90010	10	132B193    62	5093019018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			09/26/2017 12:00:00 AM			PC Info Complete	10/11/2017 12:00:00 AM	ADDRESS	34.06145	-118.30446	Changes to an approved set of plans. All changes are clouded under delta 5. Changes include revising unit panel schedules, revising load calculations, revising floor plans, and revising single line diagram. Also adding window washing circuits and changing circuit breaker sizes for multi-family units from 125A to 100A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46459	14041-20001-29517	2179 W 20TH ST	90018	10	126B193  1013	5073030060	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.02	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM			PC Approved	04/20/2015 12:00:00 AM	ADDRESS	34.03896	-118.31167	Changes to an approved set of plans. Changes include the re-arrangement of the PV-module layout, the change of manufacturer and power output of the inverter, and change of string length.*****Previous Work Description*****PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(22) TRINA SOLAR TSM-250(1) ABB PVI-5000 TRANSFORMERLESS INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46460	19041-10000-01650	1056 N SWARTHMORE AVE	90272	11	129B125   863	4423016023	C2-1VL, T, Q	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.04802	-118.52479	Full plan check for a first time retail T.I. located in palesades village Mall. Scope includes new lighting and equipment with a total area of 2,600 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46461	18041-20001-05844	7220 W FOOTHILL BLVD	91042	7	202-5A199 526	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.24854	-118.28909	SUPPLEMENTAL TO FULL PLAN CHECK FOR FIRST TIME TENANT - INSPECTION FEES WERE CALCULATED UNDER ORIGINAL PERMITCHANGE OF USE FROM (E) RETAIL TO (N) PHARMACY.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46462	13041-20001-35006	5330 N NEAL DR	90041	14	163-5A223  50	5671007018	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.14354	-118.21284	((CHANGES MADE TO APPROVED SET. CHANGED THE BUS BAR RATING OF THE MAIN PANEL.))PV1 CENTRAL INVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46463	15041-20000-30157	2427 S COCHRAN AVE	90016	10	123B177   557	5063011022	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.03474	-118.35767	Installation of new roof mounted solar PV array.  Total system size = 1 kWac. Interconnect with 100A MSP.  Microinverter system. Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46464	13041-10000-08466	4242 S BROADWAY	90037	9	114A203   202	5111017030	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/02/2013 12:00:00 AM	ADDRESS	34.00671	-118.27814	T24 FOR CHANGE OF USE FROM CHURCH TO BAKERY. SQRFT: 2558. NEW LOAD DOES NOT EXCEED 400A. ELECTRICAL PERMIT MUST BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46465	15041-20000-01209	18041 W DEVONSHIRE ST	91326	12	204B125   152	2731010015	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	PIN	34.25766462	-118.52695245	PV2. Install roof mounted PV system sized 15.2 kW. Interconnected with main service panel. (54) CS6X-310P Modules(2) 4600TL Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46466	18041-20000-24271	19601 W ROMAR ST	91324	12	204B117   360	2726010015	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	08/18/2018 12:00:00 AM	ADDRESS	34.25466	-118.56101	Plan check for PV roof mounted system, system size: 11.4kW with 35 module adn 1 inverter(11.4kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46467	10041-20000-07471	7725 N AIRPORT BUSINESS PARK WAY	91406	6	189B137    88	2205009086	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM	04/23/2010 12:00:00 AM		Permit Finaled	05/25/2010 12:00:00 AM	ADDRESS	34.21108	-118.49556	TENANT IMPROVEMENT FOR OFFICE BUILDING WORKING LIGHTING AND SOME POWER. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46468	19041-10000-28238	9000 N WINNETKA AVE	91324	12	195B113    40	2782037004	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.23374	-118.57085	Change to an approved set from manufacturing/ warehouse to agriculture facility. Scope includes new lighting and equipment with a total lighting area of 21,536-SQ FT. All equipment is under (3) existing services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46469	19041-10000-44485	9440 N LURLINE AVE	91311	12	198B109   205	2748041033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	06/08/2022 12:00:00 AM	ADDRESS	34.24177	-118.58401	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY AND REPLACE FLUORESCENT TROFFER WITH LED RETROFIT KIT (INDOOR & OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46470	12041-20000-12142	5454 S CENTINELA AVE	90230	11	105B161   826	4220012021	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	PIN	33.98308742	-118.41076608	fire damage energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46471	14041-10001-16587	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	33.94248	-118.40461	REVISIONS TO LIGHTING SYSTEM:DDED LOCKER ROOM/RESTROOM AND CHANGE LOCATION S OF SOME LUMINAIRES IN THE TENANT SPACETI in terminal 5 in LAX.  Plan check for power and lighting.  Total area = 425 sq. ft.Provide lighting, electrical distribution, 20 kVA UPS system, and power for 2 renovated spaces used as IT rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46472	14041-10004-30464	500 S SANTA FE AVE	90013	14	126A217   245	5164004010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM			PC Approved	05/08/2019 12:00:00 AM	ADDRESS	34.04107	-118.23124	(This is plan check only, permit is covered under 14041-10002-30464) CHANGES TO APPROVED PLANS ON LEVEL 3, 4, AND 5 (PENTHOUSE). CHANGED THE AMOUNT OF LIGHTING INSTALLED IN THE CORRIDOR, AND REVISED T24 FORM ACCORDINGLY.<<4,000 Amp Service for new office Building. NEW 4-STORY W/ MEZZ. OFFICE BLD'G. 98,825 S.F. (4-STORY TYPE IIB OVER 1-STORY TYPE IA)>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46473	15041-20000-15551	4269 N BECK AVE	91604	2	165B169   688	2365026022	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.14694	-118.38348	Installation of new roof mounted solar PV array.  Total system size = 10.7 kWac.  Central inverter system with 2 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46474	16041-20000-44773	14675 W RINALDI ST D, E, F	91340	7	213B149   125	2612015011	C2-1-CPIO	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			PC Approved	12/21/2016 12:00:00 AM	ADDRESS	34.2813	-118.45299	Plan check for Title 24 only. Project site is (3) tenant spaces within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,948 sq. ft.Note: Building permit has been pulled under 16016-10000-13994. Electrical permit fees has been paid under 16041-20000-31725 and 16041-20001-31725.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46475	19041-20000-50746	1348 E 27TH ST	90011	9	117A211   209	5118014011	R3-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Apartment			12/12/2019 12:00:00 AM			PC Info Complete	10/29/2021 12:00:00 AM	ADDRESS	34.01492	-118.24942	FULL PLAN CHECK FOR NEW APARTMENT BUILDING. NEW 800A SERVICE WITH LIGHTING AND POWER LOADS. TOTAL SQUARE FOOTAGE =  SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46476	14041-10001-06110	1307 N DOHENY DR	90069	4	144B169   125	4392010006	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.09412	-118.39231	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(10) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46477	16041-10000-32905	725 S FIGUEROA ST #1750	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Issued	11/15/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR (E) OFFICE SPACE LOCATED ON A HIGHRISE BUILDING. TOTAL AREA  1384 SQ FT. EMERGENCY LIGHTS USING THE EXISTING EMERGENCY BRANCH CKT FROM GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46478	10041-10000-02167	300 E WATER ST	90744	15	027B209   227	7440010***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2947.00	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM	03/23/2010 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	33.76636	-118.25616	Plan check for power new electrical system.  Electrical system to power prefab. modular buildings and to floating dock.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46479	18041-20001-12550	12955 W BLYTHE ST	91605	2	189B161   617	2303018028	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM			PC Approved	04/18/2018 12:00:00 AM	ADDRESS	34.21383	-118.41618	Expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46480	10041-10000-12013	720-734 E 62ND ST	90001	9	105B205  1374	6007010005	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.00	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	04/25/2011 12:00:00 AM	ADDRESS	33.98311	-118.26212	UPGRADE THE SERVICE TO A BUILDING WITH 4 EA COMMERCIAL TENANT SPACES ( EXISTING)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46481	18041-20000-01674	5506 W HOLLYWOOD BLVD	90028	13	148-5A193 144	5544025032	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.10158	-118.3096	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR RESTAURANT & BANQUET HALL.BUILDING PERMIT # 17016-10001-14346	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46482	18041-20000-15813	9540 N VASSAR AVE	91311	12	201B105   236	2746016055	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.24413	-118.60451	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600 amps. No new load under this scope of work. All existing load will be reconnected to new service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46483	16041-10000-22425	3273 W CASITAS AVE 104, 205-& 208	90039	13	153B209   393	5436002023	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.11638	-118.25202	TI FOR FIRST TIME TENANT. PC FOR POWER AND ENERGY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46484	17041-10000-15031	520 S SAN JULIAN ST	90013	14	127-5A213 258	5148012016	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			05/05/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.04388	-118.24528	Installation of new fire alarm system in 5 story 114 unit apartment building.  Total system size = 220 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46485	17041-10000-27487	19408 W LONDELIUS ST	91324	12	195B117   145	2783027015	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.22976	-118.55604	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF ONE FIRE ALARM PANEL AND 60 DEVICES. PERMIT SHALL REFERENCE CE CASE #746233. PERMIT WILL EXPIRE 30 DAYS FROM DATE OF ISSUANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46486	18041-10000-08070	13101 W FOOTHILL BLVD	91342	7	219B157   269	2513028034	[Q]MR1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.29783	-118.41953	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 50100 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46487	14041-10000-17096	24709 W STONEGATE DR	91304	12	189B089   472	2017028031	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.21033	-118.65657	Install roof mounted solar system.  24 modules with microinverters.  Total system size = 6.6 kW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46488	17041-20000-29792	1680 N VINE ST 10th Floor	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 5,282 sq. ft.Note: Building application has been generated under 17016-20000-24007	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46489	19041-20000-44851	10440 N SUNNY BRAE AVE	91311	12	207B109   643	2707034018	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.26024	-118.58042	Plan check for PV system, PV system size: 11.055KW with 33 PV Modules and and 1 inverter(10KW) Center fed panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46490	17041-20001-32256	7253 N LURLINE AVE	91306	3	186B109   974	2113015006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.20263	-118.58426	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.7kW ungrounded system [(1) 4kW + (1) 3kW].(26) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46491	12041-10000-29380	20946 W GERMAIN ST	91311	12	207B109   476	2706017036	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.26297	-118.59011	PV1. Plan check for new 10.29 KW roof mounted photovoltaic system for a single family residence.  42 modules, 2 invereters, 1 load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46492	16041-10000-01980	201 N FIGUEROA ST 5TH FLOOR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS, PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG. TOTAL SQUARE FOOTAGE 18338.  SCOPE OF WORK IN THE 5TH FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46493	12041-20000-02617	300 S GRAND AVE 31st fl.	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Info Complete	01/22/2013 12:00:00 AM	PIN	34.05243427	-118.25124731	31 st fl. bathrooms, office t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46494	13041-10000-06753	1090 W 7TH ST	90017	1	130-5A207 630	5143004011	CW	Central	Westlake	Downtown Los Angeles		2093.00	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.05065	-118.26411	T24 FOR NON-HIGHRISE OFFICE SPACE. SQRFT 3990. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY. INSPECTOR VERIFY THIS BUILDING IS NOT A HIGHRISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46495	13041-10000-35764	7111 W MELROSE AVE A+B	90046	5	141B181   555	5525009022	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.08361	-118.34463	Plan check for power and energy. New restaurant in existing space (Tatsu - ramen with a soul), Total area 1984 sq ft. Existing panels. This restaurant is related in units 1117A and 1117B.(per Mehdi). Blgd app # 11014-10000-03135:T.I. of restaurant.  169 S.F. addition of patio cover for outdoor dining area. Changes on plans: emergency on general ltg, multilevel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46496	10041-10000-18623	948 S CROCKER ST	90021	9	124-5A211 204	5132002029	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			09/20/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Expired	12/12/2012 12:00:00 AM	ADDRESS	34.03501	-118.25004	TI IN AN EXISTING RETAIL STORE. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46497	11041-10000-04745	11354 W SATICOY ST	91352	2	186B173   281	2315015048	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM			PC Approved	03/10/2011 12:00:00 AM	ADDRESS	34.2083	-118.37876	CHANGE OF USE FROM RETAIL TO RESTAURANT/FLOWER SHOPPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46498	12041-20000-06261	6300 N CANOGA AVE 9th Floor	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.18492	-118.59722	T.I. to high rise building on the 9th floor.  Install general lighting in offices 902, 903, and 904 as indicated on plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46499	17041-10000-22556	10250 W SANTA MONICA BLVD # 2650	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Tenant improvement of existing core/shell space, new lighting and receptacle branch circuits,new panels, and 30KVA transformerFULL PLAN CHECK	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
46500	17041-20000-19166	2022 W SUNSET BLVD	90026	13	139-5A207  92	5404003038	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1957.20	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			Reviewed by Supervisor	07/06/2017 12:00:00 AM	ADDRESS	34.07751	-118.2627	Plan check for power and energy. Project site is a new 4-story, mixed use building with 39 apartment units and commercial offices. Total lighting area = 29,129 sq. ft.Note: Building permit has been issued under 14010-20000-00419 on 12/07/2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46501	17041-10000-43324	4226 E VERDANT ST	90039	13	159B205   455	5594006032	[T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.13138	-118.26456	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 110 FA DEVICES, AND 1 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46502	15041-10000-05884	1149 S HILL ST 9TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	34.03926	-118.26099	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK PARTIAL 9TH FLOOR.  TOTAL SQUARE FOOTAGE 11703	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46503	15041-20000-19085	6320 N TOPANGA CANYON BLVD Bldg G-Suite 1623	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.18578	-118.60536	TI to commercial building (flower shop). First time tenant. Plan check for power and energy. Adding new lighting including emergency. Total sqft. 2,000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46504	17041-10000-45800	8219 N VARIEL AVE	91304	3	192B105   645	2109002005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.21891	-118.59302	PC for Tesla powerwall for SFD. Installing new battery with subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46505	19041-20000-52707	20001 W RINALDI ST	91326	12	213B113   482	2701100009	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	04/10/2020 12:00:00 AM		Issued	04/10/2020 12:00:00 AM	ADDRESS	34.27571	-118.57047	Distribution, power and lighting for commercial shell space first-time tenant improvements.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46506	14041-20000-35184	707 W WILSHIRE BLVD 47 FLR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS AND CIRCUITS.  PLAN CHECK FOR ENERGY AND EMERGENCY.  TOTAL SQUARE FOOTAGE 16570.  SCOPE OF WORK TO BE ON THE ENTIRE 47TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46507	12041-10000-00175	969 N LA BREA AVE	90046	5	144B181   624	5531016018	MR1-1	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	PIN	34.08839653	-118.3447015	alterations in retail storeplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46508	19041-20000-28023	1801 S CENTURY PARK EAST valet-lobby	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.06201	-118.41537	ti to an existing commercial space, valet lobby.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46509	16041-10000-08104	10828 N AQUEDUCT AVE	91344	12	207B141   153	2662022006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Issued	04/19/2016 12:00:00 AM	ADDRESS	34.26732	-118.47385	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.18KWdc / 7.31KWac(34)MODULES-SILFAB SOLAR SLA-M 270W(34)MICROINVERTERS-ENPHASE M215-60-2LL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46510	17041-10000-13311	5415 S JANDY PL	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Issued	04/24/2017 12:00:00 AM	ADDRESS	33.98121	-118.41639	PC AND PERMIT FOR SERVICE UPGRADES TO EXISTING BUILDING. THIS IS LANDLOAD SCOPE OF WORK TO PROVIDE NEW DISTRIBUTION FOR FUTURE TENANTS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46511	11041-20000-17551	14448-14452 W TITUS ST	91402	6	192B149   534	2212003011	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM			PC Approved	08/18/2011 12:00:00 AM	ADDRESS	34.2196	-118.44817	T24 Energy for existing retail spaces #14448/50/52.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46512	18041-10000-00835	11201 N WHITE OAK AVE	91344	12	210B129   185	2711019013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	03/24/2018 12:00:00 AM	ADDRESS	34.27409	-118.51991	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 50 MODULES (HANWHA Q-CELL. Q PEAK-G4.1 305), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS P320) WITH TWO CENTRAL INVERTERS (SOLAR EDGE SE6000H-USRGM) AND  (SOLAR EDGE SE7600H-USRGM) .  SYSTEM SIZE IS 15.25 KWdc AND 13.6 KWac.Fees $0 Due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46513	17041-20000-38938	14648 W WEDDINGTON ST	91411	4	172-5A149 189	2249008012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.16656	-118.45245	Plan check for the addition of a battery back-up system to an existing roof-mounted PV system.Note: Existing PV system has been permitted under 17041-90000-34015	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46514	19041-10000-53355	2931 S LA BREA AVE	90016	10	120B177   262	5049029016	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM			PC Info Complete	10/27/2020 12:00:00 AM	ADDRESS	34.02801	-118.35334	POWER PLAN CHECK FOR SINGLE FAMILY RESIDENCE PER APPLICANT'S REQUEST. SCOPE INCLUDES INSTALLATION OF A 200 AMP SERVICE, 200 AMP MSA WITH A 225 AMP BUS, CIRCUITS, LIGHTS AND A 100 AMP SUB PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46515	07041-10006-19016	751 N FAIRFAX AVE	90046		141B177   298	5527012031	(T)(Q)RAS4-1VL		Hollywood	Mid City West			Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM			PC Approved	01/21/2010 12:00:00 AM	ADDRESS	34.08526	-118.36177	Revision to the approved plan pages E-2 and E7 only, change in Single line diagram only.  No branch circtuit changes.  Changes to the feeders type, and also other minor changes to the drawing for clarification of the installation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46516	16041-10000-31180	350 S GRAND AVE 31ST FLOOR	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	Title 24 plan check only.  Total area = 15,396 sq. ft.     T.I. to 31st floor of existing commercial office highrise.  New lighting and receptacle loads.  Panels to remain existing.  Corridor and elevator lobby excluded from scope of work.  Backroom expedite plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46517	17041-10000-28270	304 S BROADWAY STE#360	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Info Complete	08/10/2017 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR T24 ONLY TENANT IMPROVEMENT TO  (E) OFFICE SPACE . NO CHANGE OF USE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46518	13041-10001-32601	8525 N TOBIAS AVE	91405	6	192B149    90	2653017051	(T)[Q]R4-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Apartment			11/20/2013 12:00:00 AM			PC Approved	08/22/2014 12:00:00 AM	PIN	34.22596848	-118.45231727	][][EXPEDITED PER APPLICANT REQUEST; SUBMITTAL 2 WAS ALSO CHANGED TO ACCOUNT FOR THE ADDED MODULES ON REGULAR APPLICATION, UNDER 13041-10000-32601 ][][PV2, ROOF-MOUNTED SOLAR INSTALLATION FOR APARTMENT BUILDING. SYSTEM SIZE IS 175 KW. FEEDING INTO 3 DIFFERENT METERS.BUILDING PERMIT UNDER: 13016-10000-24139APN #2653-017-051	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46519	18041-10000-09741	18340 W LAHEY ST	91326	12	210B125   333	2715029041	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.27257	-118.53333	PC FOR NEW ESS (DC COUPLED)WITH EXISTING PV SYSTEM.SCOPE INCLUDES 1 LG BATTERY WITH AUTO TRANSFORMER AND NEW SUBPANEL.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46520	12041-20000-05825	6250 E YORK BLVD	90042	1	153A231    81	5492034009	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.11479	-118.18298	ENERGY PLAN CHECK JACK IN THE BOX	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46521	14041-10000-18629	5503 N BELLAIRE AVE	91607	2	174B161   619	2346028009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.17053	-118.40955	PV1 8.67KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(2) inverters: {PVI-3.6-OUTD-US }]. [(34)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46522	15041-20000-00400	8857 N PENFIELD AVE	91324	12	195B113   102	2782033010	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2015 12:00:00 AM			PC Approved	01/07/2015 12:00:00 AM	ADDRESS	34.23154	-118.5691	revisions to an approved set of plans. revising module circuit routing. plan check only, reference master permit # 140412000034908 PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46523	14041-10000-25145	900 N CAHUENGA BLVD	90038	13	144B185  1190	5533019012	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.0873	-118.32862	TI in an existing non highrise commercial building. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46524	17041-20000-32817	9527 N LANGDON AVE	91343	7	201B145   622	2656012003	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.24384	-118.46991	PV1.  Install  15 kW DC roof mounted grid tied PV system.  (60) modules with Enphase M250 microinverters.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46525	17041-10000-17207	3475 S BENTLEY AVE 1-6	90034	5	117B157   126	4251028025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Apartment			05/23/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.02023	-118.4212	PC FOR NEW 6-UNIT 2-STORY APARTMENT BLDG. TOTAL SERVICE 600A 1P/3W 240V.TOTAL  AFFECTED AREA 10000 sq.ft. BLD# 16010-10000-04086***Plan checker to verify total area***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46526	15041-10000-23013	1836 S COLBY AVE 1-49	90025	11	126B149   704	4261024025	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.04086	-118.44902	FULL PC, NEW 4 STORY 49 UNIT APARTMENT BUILDING. 1600A SERVICE ABOUT 6 TYPICAL UNITS. PC FOR ENERGY AND POWER. TOTAL SQ. FT. = 37739    FEES PER APPLICANT (((VARIANCE NEEDS TO BE SUBMITTED AT A LATER DATE BY APPLICANT))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46527	19041-10000-43440	7900 S LOYOLA BLVD	90045	11	129A215   135	5161020028	R4-1, [Q]C2-4D-O-CDO	West Los Angeles	Central City, Westchester - Playa del Rey	Historic Cultural, Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	33.96604	-118.41693	Energy PC only, Area of scope 725sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46528	16041-20001-02856	5846 W VIRGINIA AVE	90038	13	144B189   527	5534017019	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.09167	-118.31734	05-25-16 Changes to an approved set of plans. Changes include replace new typ of light fixtures. {{{{{Plan check for energy only. Installing outdoor lighting for parking lot. 7,500sqft.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46529	12041-10001-24740	6060 W CENTER DR 900	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	33.97602	-118.39073	Plan check T24 Energy/Emergency lighting for tenant improvement for suite #900. Permit under  #12041-90000-24740	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46530	19041-20001-02668	1355 S HOPE ST	90015	14	126A207   228	5134011023	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			06/19/2019 12:00:00 AM			Corrections Issued	06/19/2019 12:00:00 AM	ADDRESS	34.0382	-118.26675	PLAN CHECK ONLY, CHANGES TO APPROVED SET, CHANGE TO LOAD CALC (ADDING AC AND HEAT PUMPS TO ALL APARTMENT UNITS), CHANGE TO VOLTAGE DROP CALCS, CHANGE TO SUB PANELS AND CHANGE TO FEEDER LEGEND.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46531	17041-20000-36363	5461 W JEFFERSON BLVD	90016	10	120B177   474	5048017040	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Issued	11/07/2017 12:00:00 AM	ADDRESS	34.02617	-118.36558	"""0$ permit fees due to senate bill 1222""PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 60KW INTERCONNECTED WITH MSP.(253) mitsubishi modules(1) yaskawa 60kw"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46532	14041-10000-10258	6801 S PARK TER # 330	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	33.97698	-118.39328	PLAN CHECK ONLY: Express PERMIT HAS BEEN PULLED UNDER THE FOLLOWING APPLICATION#: 14041-10000-05799. PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE (see bldg#:14016-10-02985).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46533	16041-20000-13243	11156 S TOWNE AVE	90061	8	087A207    61	6073021021	R2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	33.93364	-118.26721	PV1.  Installation of a 3.36 kW roof-mounted PV system.  Central inverter standard plan.  (12) modules with (1) 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46534	18041-10000-07864	7417 N VAN NUYS BLVD	91405	6	186B149   389	2218004016	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM			PC Info Complete	03/05/2018 12:00:00 AM	ADDRESS	34.20537	-118.44897	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT FOR NEW DOLLAR TREE STORE IN EXISTING COMMERCIAL TENANT SPACE. INSTALL NEW LIGHTING AND POWER, AND REUSING ALL EXISTING PANEL BOARDS IN  THE SPACE. TOTAL AREA: 9,570 SQ.FT((B# 18016-10000-05447))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46535	16041-20000-44990	5400 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	09/29/2017 12:00:00 AM		Issued	09/29/2017 12:00:00 AM	ADDRESS	34.06201	-118.34659	Plan check for power only. New 1200A and 800A distribution boards for 2 new tenant spaces (existing restaurant space that was split into 2) that are being restored to shell conditions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46536	15041-20000-03583	1770 N ORCHID AVE	90028	13	150A185   365	5548004027	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.10361	-118.33998	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP  AND 63 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46537	18041-10000-18657	21700 W OXNARD ST 1040	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.17901	-118.60179	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. 1915 SQFT. HIGH RISE. SUITE 1040	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46538	12041-20000-04827	1125 S BOYLE AVE BLDG 2	90023	14	123A221   272	5170008***	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM			PC Approved	03/07/2012 12:00:00 AM	ADDRESS	34.03064	-118.22048	PARKING LOT LIGHTING. ENERGYPERMIT FOR USE OF LAND FOR PARKING LOT OF NON REQUIRED PARKING.  ADD 9 ADDITIONAL PARKING STALLS TO PORTION OF EXISTING PARKING LOT.  THIS LOT AREA IS PART OF NEW LOT LINE ADJUSTMENT.  SEE 07010-10000-04540 FOR SITE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46539	16041-10000-39882	1234 S NEW HAMPSHIRE AVE	90006	1	129B197   941	5078028014	R4-1VL	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.04811	-118.29251	PC for eneergy only. Outdoor lighting. Remove HID fixtures and replace with new LED fixtures Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46540	14041-20000-17140	2409 S VERMONT AVE	90007	8	123B197   510	5054026031	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.03421	-118.29179	TI for power and energy plan check on a dental office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46541	16041-20000-21668	4600 N SAN FELICIANO DR	91364	3	165B101   188	2076024017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.15002	-118.61263	PV1.  Install 9 kW roof mounted PV system.   Microinverter standard plan.  (36) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46542	12041-10000-15752	3130 W OLYMPIC BLVD	90006	10	129B193   325	5080025030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.05241	-118.30391	ADDING NEW LUMINAIRES IN THE RECEPTION AREA OF AN OPTOMERY OFFICE # 105PLAN CHK IS FOR TITLER 24.  Permit fee for 3 new circuits is under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46543	12041-10000-08695	376 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Expired	12/03/2014 12:00:00 AM	ADDRESS	33.93089	-118.26675	PLAN CHECK NEW 16.5KW ROOF MOUNTED AND GROUND MOUNTED PHOTOVOLTAIC SYSTEM FOR APARTMENT BUILDING.  EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46544	13041-20000-14331	4416 W GAINSBOROUGH AVE	90027	4	153A201   209	5588026010	RS-1	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.11313	-118.28614	PV-1. Plan check for microinverters. Inverter output sum is 6.45kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46545	14041-20000-26701	24374 W WELBY WAY	91307	12	183B089   741	2034005039	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM			Reviewed by Supervisor	10/15/2014 12:00:00 AM	ADDRESS	34.19393	-118.65649	PV1.  Install 17.7 kW DC roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.new system has been specified. this ppalication is now void.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46546	15041-10000-21057	11150 W SANTA MONICA BLVD 15TH FLOOR	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.04704	-118.44563	T24 ONLY. TI FOR OFFICE IN AN EXISTING HIGH RISE BUILDING. TOTAL AREA 6521 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46547	14041-10000-05437	7306 N COLDWATER CANYON AVE # 5	91605	2	186B161   569	2324005039	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.20333	-118.41361	T24.REMOVING EXISITING LIGHT FIXTURES AND REPLACING NEW FLORESCENT FIXTURES. TOTAL  AREA  2472 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46548	19041-10000-13554	4536 W 63RD ST	90043	8	105B177   425	4003022008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	33.98249	-118.35424	(ePlan) LADWP Community Solar Program: 2.24 kW AC - 8 solar modules and 8 enphase S280 micro-inverters. 1 circuit. 1 service. interconnected through meter adapter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46549	19041-20000-36902	22720 W MOBILE ST	91307	12	180B097   512	2038038011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Issued	09/16/2019 12:00:00 AM	ADDRESS	34.18791	-118.62237	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.34 KW DC/ 10 KW AC. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH OPTIMIZERS AND A 10KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46550	19041-10000-20394	2202 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.03804	-118.44089	PC (ENERGY ONLY) FOR TENANT IMPROVEMENT TO EXISTING RESTAURANT. AREA OF SCOPE 1,917SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46551	13041-10000-34009	735 E 12TH ST STE # 307	90021	14	124-5A211 353	5132011241	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.03328	-118.25222	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 934 SQ FT. REPLACING TOTAL OF 2 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46552	15041-10000-31444	12751 W MILLENNIUM lot 24-28	90094	11	102B161  1227	4211033053		West Los Angeles				2756.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	PC FOR T24 ONLY (2008). HARDSCAPING FOR RESIDENTIAL APARTMENT.  RETAIL  LINK(3-1), PORTIONS OF LOTS 24-28, TRACT 60110-01. TOTAL AREA 6596 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46553	17041-10000-42508	4401 W SUNSET BLVD	90027	4	147A201   190	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.09708	-118.28526	PC FOR TITLE 24 ENERGY ONLY FOR ONE STORY ADDITION TO EXISTING DINNING ROOM SCOPE INCLUDES INSTALLING NEW CIRCUITS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1320 SQ. FT. B#17014-2000-00403	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46554	19041-10001-49782	1255 N CHEROKEE AVE	90038	4	144B185   173	5532003028	R3-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			PC Approved	12/16/2019 12:00:00 AM	ADDRESS	34.0941	-118.33541	Expedite per applicant request. NEW ROOF MOUNTED PV1 SYSTEM WITH 136 PV TILES (TESLA SRV 3) AND 2 CENTRAL INVERTERS( DELTA SOLIVIA 5.2 EACH )  ON A SINGLE FAMILY HOME. SYSTEM SIZE IS 7.95 KWdc AND 10.4 KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46555	15041-10000-03435	200 WORLD WAY #233	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	08/23/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for power and title 24.  Total area = 550 sq. ft.Installation of new electrical distribution equipment (3 panels and 1 transformer in series) in airport space.  First time tenant.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46556	16041-10000-00167	12130 W MILLENNIUM	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.98008	-118.40646	(15) ADDITONAL DEVICES TO AN EXISTING METHANE SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46557	13041-20000-24324	8527 N BOTHWELL ROAD PV1	91324	12	192B117   192	2783013022	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.22543	-118.56123	New roofmount Enphase Microinverter system for an existing single family dwelling.  Plan check is only for the PV system, NOT for service upgrade or derating of main breaker.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46558	14041-20000-27548	7842 N TEESDALE AVE	91605	2	189B161   705	2305017009	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Expired	11/10/2016 12:00:00 AM	ADDRESS	34.21324	-118.41045	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.2kW.(2) ABB PVI-3.6-OUTD-S-US-Z-A transformerless inverter(34) Kyocera KD255GX-LFB3 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46559	18041-20000-00541	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	33.87528	-118.29083	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR THE 5TH FLOOR. BUILDING PERMIT # 17016-10000-34372	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46560	17041-20001-31585	20631 W GRESHAM ST	91306	3	195B109   104	2780009005	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.23071	-118.58299	Expedited plan check fee.PV1.  Install 7.15 kW roof mounted grid tied PV system.  Install 27 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46561	11041-10002-24825	1233 S NORTON AVE 1-4	90019	10	129B189   811	5081007021	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Apartment			07/17/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.04852	-118.3238	Modification to previously approved set of drawings, two new sub-panels.  The Plan Check is only for the Photovoltaic system.  No other loads are part of this plan review.                            <<<<<solar system 4.7 kw apartment building>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46562	18041-10001-12963	5156 S BRYNHURST AVE	90043	8	108B185   121	5013007015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM			Re-Activate Application	02/19/2019 12:00:00 AM	ADDRESS	33.99513	-118.33314	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE MODULE AND INVERTER TYPE. PC ONLY.____________________________________________________________________________PV1. ADDING A NEW STRING OF MODULES FOR AN EXISTING PV SYSTEM. SCOPE INCLUDES ADDING 7 MODULES. ADDING 1.96KWdc TO AN EXISTING 3.06KWdc PV SYSTEM. TOTAL DC WATTAGE FROM EXISTING AND NEW IS 5.02KWdc.  THE AC SYSTEM SIZE REMAINS 3.6KWac. (7)MODULES-Q-CELLS # Q. PLUS-G4.1/SC-280	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46563	19041-20003-06363	2439 N RIVERSIDE PL	90039	13	148-5A211 150	5440026008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM			PC Approved	07/19/2019 12:00:00 AM	ADDRESS	34.10129	-118.25338	"07-19-2019 Changes to an approved set of plan, changes include re-locate Tesla PowerWall and remove a disconnect. All changes has been clouded ""b"". plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46564	18041-10000-43458	20318 W SHERMAN WAY	91306	3	183B113    56	2136001012	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.20085	-118.57622	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 21 MODULES (TSM 280) , 21 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 5.8KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46565	13041-10001-35387	3917 S WELLINGTON ROAD	90008	10	117B185   910	5045009004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/07/2014 12:00:00 AM	ADDRESS	34.0151	-118.33926	Expedited RSES plan check per applicant request. {{PV1, Install 2 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformerless inverter: Solaredge SE 3000A-US. (8) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46566	15041-10000-01306	8074 W MELROSE AVE	90048	5	141B177   624	5528009033	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	PIN	34.08348675	-118.3656881	TI to (E) retail and commercial office tenant space.  Plan check for energy.  No emergency egress lighting per existing conditions (per applicant).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46567	18041-20001-24629	8101 W MELROSE AVE	90046	5	141B177   567	5528007014	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM			PC Approved	10/26/2018 12:00:00 AM	ADDRESS	34.08389	-118.36609	Revisions to approved set of plans.  Lighting revisions throughout.  (((T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR A COMMERICAL RETAIL AND CHANGE OF USE PORTION OF BUILDING TO CAFE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5837 SQ. FT.  B#18016-30000-18146)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46568	19041-30000-19955	801 E E ST	90744	15	030B209   741	7424014021	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	33.77626	-118.25281	Plan check for power and energy. Project site is a new warehouse with mezzanine for cold storage. Project scope is a new 2,000 Amp service and a total lighting area of 56,368 sq. ft.Note: Building application has been generated under 19010-10000-01761	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46569	15041-10000-09727	12338 W VENTURA BLVD	91604	2	162B165   263	2369002022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.14278	-118.40219	TI TO AN EXISTING SINGLE STORY COMMECIAL BUILDING.  RETOFIT EXISTING LIGHTING TO LEDS.  PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FOOTAGE 3754	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46570	16041-30001-17655	513 E 32ND ST	90011	9	118-5A207 304	5120019025	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.01769	-118.26562	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (13) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46571	18041-20000-16613	23412 W MAESTRO PL	91304	12	186B093    53	2027001032	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.20975	-118.63895	Plan check for PV roof mounted system, system size: 7.6kW with 22 modules and 1 inverter(7.6kW) connected to ceter feed center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46572	18041-10000-33160	340 S MAIN ST 2nd & 3rd-Flr	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	33.99519	-118.47673	Energy plan check for the pantry area of the 2nd and 3rd floor of a commercial building. Scope include new lighting and equipment with a total area of 2740-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46573	14041-10000-35492	1046 S SEASIDE AVE	90731	15	015B205    26	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.73339	-118.26854	Remove HID fixtures and replace with new LED fixtures as per DWP retrofit program.  Plan check for energy.  Plan check for machine shop and paint shed; permit for machine shop.  Separate permit under 14041-10000-35518 for paint shed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46574	15041-10000-09095	4564 S DON VALDES DR	90008	8	111B177    76	5027005016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Expired	06/13/2017 12:00:00 AM	PIN	34.00322003	-118.3540159	PV1 4.2KW AC (4.578KW DC ) ROOF-MOUNTED  system with (1) PVI-4.2-OUTDinverter and (14) Sunpower E20-327 modules interconnecting to the main service.Customer was advised about the online servicie, but insist to have the plan check over the counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46575	14041-20000-23952	13691 N GAVINA AVE #604	91342	7	225B165     2	2580017007	(T)(Q)RD6-1, (T)(Q)RD6-1-K, A1-1-K, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Expired	09/30/2016 12:00:00 AM	ADDRESS	34.31924	-118.40195	PV1Microinverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5.59kW.(26) EnPhase M215 microinverters(26) SolarWorld SW250W POLY pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46576	12041-20000-04906	14006 W RIVERSIDE DR #249	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24 lighting plan check for remodeled lighting in take out restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46577	13041-20000-12275	22708 W VICTORY BLVD	91367	3	180B097   634	2039020026	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.18625	-118.62139	Plan check for energy only. Bathrooms for AAA. 388 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46578	15041-20000-24433	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	Plan check for a fire alarm system. Project site is an existing commercial building. System consists of (1) FACP, (4) FAPSs, and (117) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46579	13041-10000-35451	1610 N ALVARADO ST	90026	13	142-5A209 246	5419002012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.0837	-118.25953	PV1, Install 3.75 kw DC roof-mounted solar array, interconnect with main service for a one story house. (1)Transformerless inverter(s): SOLAREDGE SE 3800A-US, (15)Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46580	19041-10000-40264	13700 W MARINA POINTE DR	90292	11	105B153   622	4229020232	C4(OX)-2D, R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	33.98482	-118.44503	INSTALLING 36 NEW LEVEL 2 EV CHARGERS WITH A NEW 1,200 AMP SERVICE @ 480/277V,  AND 3  NEW 112.5KVA TRANSFORMERS & PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46581	17041-10000-00855	1130 W D ST BLDG 10-LOT 8	90744	15	027B201   403	7417010919	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM				PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING#1,0 LOT 8. SCOPE INCLUDES 44 FA DEVICES AND TWO FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46582	15041-10000-12642	456 N FAIRFAX AVE	90036	5	141B177  1234	5527030025	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.07979	-118.36128	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46583	16041-10000-03780	1888 S CENTURY PARK EAST 14TH FLR	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.06104	-118.41402	T-24, TI REMODEL ON THE 14TH FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 9282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46584	18041-10000-30969	802 S ALVARADO ST	90057	1	132A203   307	5141020017	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.05463	-118.27779	PC FOR OFFICE TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 1,082 SQFT. THIS IS SUPPLEMENTAL PERMIT TO 18041-10000-27650((B#18016-10000-21612))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46585	14041-10000-21251	1818 W 60TH ST	90047	8	105B193   567	6001017006	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/07/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	33.98515	-118.30969	Repair exisitng commercial building.  New service 600A, 2 new panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46586	13041-10004-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.09649	-118.33888	10/18/2015Changes to an approved set of plans. Changes are cluded on delta 28. Changes include the relocation of the inverter battery cabinet and adding block splices from MSB to RA-2. PC only.  (((REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  )))((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46587	16041-10000-05443	8334 S LINCOLN BLVD	90045	11	096B157   258	4113016019	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	33.96192	-118.42081	PC FOR T24 ENERGY ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46588	15041-20000-09516	12696 N WOODCOCK AVE	91342	7	222B149  1095	2507001017	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.30114	-118.4488	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Microinverter system with two branch circuits.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46589	13041-10000-21753	863 S RIMPAU BLVD	90005	4	132B185   300	5090008013	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Expired	09/23/2015 12:00:00 AM	ADDRESS	34.05929	-118.33299	PV1 ROOF MOUNTED SOLAR INSTALLATION IN A SINGLE FAMILY DWELLING. SYSTEM SIZE IS 6.86 KW DC AND 6 KW AC. USING 28 MODULES AND 1 INVERTER. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: POWER-ONE # AURORA PV1-60000-OUTD-US-Z]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46590	18041-20000-20186	22704 W SYLVAN ST	91367	3	177B097   158	2039019026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.18442	-118.62132	Plan check for a PV1 roof-mounted PV system. System size is 15.2KVA consisting of (2) inverter - solivia 7.6TL, (53) modules, and (1) load centers.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46591	16041-30000-01442	9560 W PICO BLVD	90035	5	132A167   255	4306002003	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.05506	-118.39714	Title 24 plan check only.  Total area = 2,020 sq. ft.   T.I. to existing commercial office space.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46592	15041-20000-19277	7613 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM				Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46593	17041-20001-06221	7740 W MULHOLLAND DR	90046	4	159B173   642	5570013009	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	02/17/2018 12:00:00 AM	ADDRESS	34.1288	-118.36619	12/11/2017 Plan check for the installation of a 600-Amp rated distribution board. LADWP service size is 400 Amps.*****Previous Work Description*****UPGRADE MAIN SERVICE TO 400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46594	16041-10000-05382	10100 W SANTA MONICA BLVD 25 FLR	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISITNG PANELS.  SCOPE OF WORK TO BE PERFORMED IN 25TH FLOOR.  TOTAL SQFT 1190.  PLAN CHECK FOR ENEGY AND EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46595	17041-20000-02308	8351 N MARLA AVE	91304	12	192B089    46	2005020007	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Issued	01/24/2017 12:00:00 AM	ADDRESS	34.22066	-118.64501	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (29) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46596	17041-20000-34932	213 1/2 S FRESNO ST	90063	14	124-5A227  58	5179005037	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.03691	-118.20021	Plan check for solar pv system, roof-mounted array on 3-unit apartment building.3kW ungrounded system. (7) 300W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46597	19041-20000-34181	20607 W BLUEBIRD CT	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.29719	-118.58259	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46598	14041-10000-16494	1118 S ABBOT KINNEY BLVD	90291	11	108B145  1151	4238003002	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	33.9915	-118.46999	PLANCHECK FOR T24 ENERGY.  CHANGE OF USE FROM OFFICE  TO RETAIL STORE & T.I. . NEWLY CONNECTED LOAD < 400 AMPS. 5821 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46599	19041-10000-51404	19515 W NORDHOFF ST Bldg D-STE 10	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	07/15/2020 12:00:00 AM		Permit Finaled	12/24/2020 12:00:00 AM	ADDRESS	34.23567	-118.55825	"FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A FIRST TIME TENNANT BUILD OUT, SCOPE OF WORK INCLUDES ONE NEW PANEL THAT IS BEING FED BY AN EXISITING SWITCHBOARD, PLAN CHECKER TO ASK FOR A COMPLETE SINGLE LINE REFERENCE. TOTAL AFFECTED AREA IS 1047 SQFT. ((CHANGE OF USE: RETAIL TO MEDICAL OFFICE, FIRST TENANT BUILD OUT TO ""BLDG D"", NO CHANGE IN OCCUPANCY,  AND NEW PARKING MAYBE REQUIRED UPON APPLICANT VERIFICATION19016-10000-33530))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46600	19041-10000-15385	1015 S CROCKER ST STE Q26-A	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Issued	04/26/2019 12:00:00 AM	ADDRESS	34.0345	-118.2508	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46601	13041-20001-26796	11308 N SINCLAIR PL	91326	12	213B121   862	2871020010	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM			PC Approved	10/21/2013 12:00:00 AM	ADDRESS	34.27631	-118.5395	((EXPEDITE FEES))PV1 MICROINVERTER PLAN. TOTAL SYSTEM SIZE 7.3KWAC. 34 PANELS AND MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46602	19041-10000-31286	9215 W CATTARAUGUS AVE	90034	5	123B165   206	4301002007	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/28/2019 12:00:00 AM	ADDRESS	34.03591	-118.39277	pv-1 for 22 modules (panasonic VBHN330SA16) WITH OPTIMIZERS (SOLAREDGE P400). INVERTER (SOLAREDGE SE7600H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46603	18041-10000-18024	9805 N MASON AVE	91311	12	201B109   168	2748005022	(T)(Q)CM-1L, (T)(Q)M1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	06/18/2020 12:00:00 AM		Permit Finaled	03/23/2021 12:00:00 AM	ADDRESS	34.24803	-118.5802	Full plan check for a first time tenant. T.I. Scope includes new lighting and equipment with a distribution panel of 1200-Amp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46604	15041-20000-05663	5510 S LINCOLN BLVD Suite 175	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	33.97299	-118.43051	Title 24 plan check only.  Total area = 551 sq. ft.T.I. to existing office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46605	12041-10000-01842	6600 N TOPANGA CANYON BLVD FC-9	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM			PC Info Complete	04/19/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T. I. TO (E) MALL FOOD COURT FOR SPACE FC-9 ( 747 SF ). emergency lighting and title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46606	19041-20000-23887	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	T24 PLAN CHECK ONLY FOR TI TO EXISTING OFFICE BLDG. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE =  1368 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46607	14041-20000-20576	5000 N VAN NUYS BLVD Ste 210	91403	4	171A151   223	2248008087	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM			PC Approved	07/30/2014 12:00:00 AM	ADDRESS	34.16138	-118.44849	TI to (E) commercial office space.  Plan check for building energy conservation standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46608	16041-20000-07112	20412 W LORNE ST	91306	3	189B113   227	2107003011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.21727	-118.57791	Install a roof-mounted solar array on a SFD. Interconnect with a center-fed 200A MSP. Derating main to 150A.System size: 6kW (3+3). Ungrounded system. (23) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46609	19041-20000-23795	8521 S SEPULVEDA BLVD	90045	11	096B165   470	4108019029	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Apartment			06/20/2019 12:00:00 AM	03/09/2021 12:00:00 AM		Permit Finaled	05/10/2024 12:00:00 AM	ADDRESS	33.96056	-118.39657	New apartment building mix use 2500 amp service. Full  plan check for power and energy. Total square footage = 66744 sf	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46610	19041-10002-53836	7167 N RIVOL ROAD	91307	12	183B089    49	2028038003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM			PC Approved	01/08/2020 12:00:00 AM	ADDRESS	34.20126	-118.65542	New roof mounted 12.16KW PV system with 38 @ (320W) PV panels, 38 Optimizers and a 10KW cenral inverter on a single family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46611	12041-10000-06887	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	33.97704	-118.40702	Plan check for new 3000A service and switchboard supplying future buildings. Site located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46612	13041-20000-34345	10810 W CANTARA ST	91352	2	192B177   908	2407025012	[Q]M1-1-CDO, [Q]MR1-1-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Expired	04/21/2016 12:00:00 AM	ADDRESS	34.21919	-118.36541	energy plan check warehouse and offices 2nd floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46613	17041-20001-20172	1328 S SANTA FE AVE	90021	14	121-5A217 172	5168031005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	34.02781	-118.22976	08-30-2018 Changes to an approved set of plans, changes include replace different type of lighting fixture to 1 type only and use unitequipment for emergency lighting, all changes has been clouded as delta 1. Plan check only, permit covered under Master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46614	12041-10001-21378	11013 N WESCOTT AVE	91040	7	210B189   157	2551044019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2013 12:00:00 AM			PC Approved	01/02/2013 12:00:00 AM	ADDRESS	34.26926	-118.31771	CHANGES TO PERMITTED SET OF PLANS-WITH THE SAME NUMBER OF MODULES/INVERTERS RECONFIGURE TO TWO BRANCH CIRCUIT-ONE OF 10 MODULES/INVERTERS AND THE OTHER OF 7 MODULES/INVERTERS; AC OUTPUT REMAINES THE SAME; CALCULATION REVISED TO REFLEDT THAT THERE ARE TWO BRANCH CIRCUITS.ROOF INSTALLATION OF 4.16 PHOTOVOLTAIC SYSTEM USING MICRO INVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46615	11041-20000-22880	19809 W PRAIRIE ST Ste 100	91311	12	198B113   115	2761040023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	05/01/2012 12:00:00 AM	ADDRESS	34.23925	-118.56529	New fire alarm system on the 1st floor.  1 new panel and 131 new devices.  Plan check is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46616	17041-20000-09885	12601 W PIERCE ST 45, 46	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 45 and 46).10kW ungrounded system. (1) SolarEdge 10Kw. (45) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46617	16041-20000-40963	10256 ANGEL LANE	91331	7	204B165   426	2537004036	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25709791	-118.40454312	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46618	14041-10000-30270	3183 W WILSHIRE BLVD	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.06196	-118.29111	Energy plan check for TI office in a commercial building. Replacing existing lighting with regular T8 lamp with dimming ballast, control receptical, daylight control also included. Total area is 1448 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46619	15041-10001-13522	8225 S MAIN ST	90003	9	099B201  1196	6031031006	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2397.01	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	33.96436	-118.27405	Plan check for express permit per inspector correction notice.  Church TI.(((Installation of 27 recessed lights, 2 GFI, 6 plugs and 5 smoke detectors. Rewire sanctuary.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46620	14041-20000-15930	3691 N FREDONIA DR	90068	4	159B177   295	2425006003	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.13297	-118.36147	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 3 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46621	09041-20001-11057	17250 W SATICOY ST	91406	6	186B133   238	2203017042	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00, 1319.00	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM	02/18/2010 12:00:00 AM		Permit Finaled	06/23/2010 12:00:00 AM	ADDRESS	34.20822	-118.50895	Supplimental to previously approved plan. This plan check is for adding 6 additional circuit to two panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46622	19041-10000-04529	5950 W FOREST LAWN DR	90068	4	165B189    11	5581007***	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.1522	-118.31832	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46623	15041-20000-30583	23623 W LUND ST	91367	3	171B093   235	2047006021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.16683	-118.64247	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46624	19041-10000-30067	18324 W HART ST	91335	3	183B125   598	2125007004	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.19737	-118.5327	NEW 6.1KW ROOF MOUNTED PV SYSTEM WITH 20 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46625	15041-20000-36329	1318 S PALOS VERDES ST	90731	15	012B201    70	7456012014	R3-1XL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Apartment			12/30/2015 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	33.73195	-118.28124	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KW. (21) MODULES-SUNEDISON SILVANTIS F-SERIES F270KYC(21) OPTIMIZERS-SOLAR EDGE P300(1) INVERTER-SOLAR EDGE SE6000A-US 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46626	14041-20001-11887	4732 N ARCOLA AVE	91602	4	168B177   610	2420023002	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.15678	-118.3548	(((EXPEDITE)))PV1 ROOF MOUNTED MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 7.5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46627	17041-20000-40622	6150 N CANOGA AVE	91367	3	177B105    35	2149005055	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM			PC Info Complete	11/09/2017 12:00:00 AM	ADDRESS	34.18237	-118.59721	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESIDENTIAL AMENITIES. 1431+2264 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46628	12041-20000-11445	5609-5641 N COLFAX AVE	91601	2	174B169   665	2339005020	R3-1, RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	Apartment			05/17/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Expired	06/11/2014 12:00:00 AM	ADDRESS	34.17261	-118.38795	Addition of 200 combination exit sign/emergency lights to existing circuits. Low-rise apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46629	18041-10000-06639	14116 W SAYRE ST	91342	7	222B153   516	2508005016	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.30377	-118.44076	PC for 3.8kW(AC) rooftop PV system for SFD. Installing 16 modules (4.8kW(DC)) with optimizers and 3.8kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46630	13041-10000-09409	15917 W KITTRIDGE ST	91406	6	180B141   409	2233018011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Expired	05/11/2015 12:00:00 AM	ADDRESS	34.19042	-118.4801	PV1 ROOF MOUNTED SOLAR INSTALLATION ON SINGLE FAMILY DWELLING. SYSTEM SIZE IS 5.060 KW DC AND 5KW AC. [INVERTER: POWER ONE #  PVI-50000-OUTD-US(240) |||| MODULES: SUNLAN # ALEO AVIM230]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46631	16041-10000-41394	11120 S BELHAVEN ST	90059	15	088-5A209 308	6072031014	R2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	33.93447	-118.2554	PC FOR PV SYSTEM. USING CENTRAL INVERTER SYSTEM WITH 3KW INVERTER AND POWER OPTIMIZERS. SYSTEM USES 12 MODULES IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46632	19041-20000-32309	6080 W CENTER DR 8th floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	33.97713	-118.39172	T24 PLAN CHECK FOR EXISTING HIGH RISE 8TH FLOOR RESTROOM. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 540 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46633	18041-10003-00835	11201 N WHITE OAK AVE	91344	12	210B129   185	2711019013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.27409	-118.51991	03-12-2018 Changes to an approved set of plan. Changes include addition of Meter for PV System. Changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46634	19041-10000-24724	5114 N STERN AVE	91423	4	171B153   586	2269004002	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.16361	-118.4344	[E-PLAN] PLAN CHECK FOR (2) NEW ESS(TESLA POWER WALL) CONNCTED TO EXISTING PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46635	09041-20007-20042	137 N SOTO ST	90033	14	127-5A223  76	5183005019	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.20	Electrical	Electrical	Apartment			09/06/2011 12:00:00 AM			PC Approved	09/06/2011 12:00:00 AM	ADDRESS	34.04482	-118.20939	revise two feeders to two swbds.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46636	17041-10000-34397	831 E 61ST ST SUITE B	90001	9	105B209   104	6007007020	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Expired	05/21/2020 12:00:00 AM	ADDRESS	33.98454	-118.26003	REPLACE EXISTING FIXTURES WITH LED FIXTURES- TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46637	15041-20002-34585	10430 N SEPULVEDA BLVD	91345	7	207B145   770	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.26014	-118.46701	"7.6.2017 - Plan check for modifications to approved set. Updating EV panel and number of EV chargers on EV panel to meet Green Building Code requirements. Additional load. Changes clouded delta ""EV"". =======6.27.2017 - Plan check for modifications to approved set. Changing feeders from copper to aluminum + delta J clouded changes ONLY. ""PAD A"".=======PC FOR POWER AND ENERGY FOR A RETAIL SHELL BUILDING. TOTAL AREA 3750 SQ FT(CANOPY AREA).BUILDING # 15010-10000-03495"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46638	13041-10000-18198	4730 W JANET PL	90041	14	160-5A219 120	5685002025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.13448	-118.2221	Installing PV array. PV 1 roof mounted installation. 10.56 kW. 44 modules and 4 strings. central inverter. standard plan. module type: trina tsm 240. inverter type: fronius 10.0-1 uni.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46639	16041-10000-00572	1318 E 7TH ST	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.03608	-118.24052	PC FOR POWER AND ENERGY TO TWO BUILDINGS SERVED BY A SINGLE SERVICE. SCOPE INCLUDES  ADDING 4 NEW MEDIUM VOLTAGE SUBSTATION UNITS, AND NEW DISTRIBUTION EQUIPMENT. TOTAL AFFECTED AREA IS 14,003 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46640	15041-10000-19226	3531 W SUNSET BLVD	90026	13	144A203   129	5429024013	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Info Complete	06/19/2015 12:00:00 AM	ADDRESS	34.08971	-118.27667	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 1883.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46641	19041-20000-31292	10831 N DELCO AVE	91311	12	207B109    66	2707005005	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.26718	-118.57943	Plan check for PV roof mounted system, PV system size: 6.44KW DC, 5.735KW AC with 21PV modules and 11 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46642	18041-20000-29728	20757 W SPRUCE CIR	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.29517	-118.58657	pv1install roof mounted pv system sized 3.8kw AC interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46643	19041-10000-53092	1055 N KINGSLEY DR	90029	13	144B193   801	5537020035	R3-1XL, [T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	01/10/2022 12:00:00 AM		Permit Finaled	09/26/2023 12:00:00 AM	ADDRESS	34.09008	-118.30339	Replacement Fire Alarm system for (7) buildings on the site. ALL FIRE ALARM SYSTEMS INTERCONNECTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46644	12041-20001-25389	22333 W SHERMAN WAY	91303	3	183B101     5	2023028044	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.20119	-118.61325	Changes to approved set of plans. Plan check for energy and emergency lighting. Ralphs #721.T-24 LIGHTING PLAN CHECK FOR ADDITIONAL LIGHTING TRACK IN SALES AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46645	12041-10000-08514	1600 S HOPE ST	90015	9	124-5A205 107	5134014905	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	01/03/2013 12:00:00 AM	ADDRESS	34.03599	-118.26771	This is a four story building, new fire alarm , floor 1 through 4. need fire department stap.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46646	12041-10000-11957	501 W OLYMPIC BLVD	90015	14	127-5A207 178	5139007047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			PC Approved	07/05/2012 12:00:00 AM	ADDRESS	34.04328	-118.26074	Change of use from a fast food restaurant to a nail spa.  Occupancy load is less than 99 and load is 86A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46647	19041-20000-30921	3737 S MOTOR AVE	90034	5	120B165  1341	4314003037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	02/16/2022 12:00:00 AM	ADDRESS	34.02157	-118.40525	INSTALL (104) FIRE ALARM DEVICES WITH (1) FIRE ALARM PANEL IN 6 STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46648	16041-10000-41376	2860 N FLETCHER DR	90039	13	153B209   959	5436033025	M1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.11293	-118.24793	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING TO MORE ENERGY EFFICIENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46649	18041-30000-42852	11601 W WILSHIRE BLVD 11TH FLR.	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR T-24  ENERGY ONLY FOR RESTOOM AND CORRIDOR TI IN A HIGH RISE BUILDIND ON THE 11TH FLOOR. TOTAL AFFECTED AREA 1732SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLESB#18016-10000-31081	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46650	14041-20000-31168	8051 N GARDEN GROVE AVE	91335	12	189B125   219	2102010001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.21684	-118.52921	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 5.559 KW(17) SUNPOWER 327(1) PVI 6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46651	10041-20000-05153	10880 W WILSHIRE BLVD # 950	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	03/22/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	NON STRUCTURAL  TENANT IMPROVEMENT TO INCLUDE NEW PARTITIONS, CEILING TILE AND GRID, LIGHT FIXTURES AND FINISHES AND RELOCATION OF EXISTING LIGHT FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46652	14041-10000-07618	414 N FAIRFAX AVE	90036	5	141B177  1435	5527030018	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.07869	-118.36128	"FULL PLAN CHECK POWER AND ENERGY. Core and Shell as well as TI for tenant at 414 [tenant spaces #410 and 412 shall have circuit breakers in panels C and B shall be installed in separate permits]. NEW 600 A 120/240 V 3P,4W. TOTAL AREA 1310 (INSIDE) SQ FT. BLDG# 13014-10-05319: CHANGE OF USE. Expedite fee on submittal 2. 3/25/2014 - mt Changes on plan: all panels rated for 42kaic through series rating, extra panel B removed, scope of work added to sheet E-1.  �This building is designed as a Core and Shell Building only; separate building, electrical and mechanical permits are required for all future residential unit build-outs or commercial tenant space build-outs.�{{{ Description  of  the  building   first   floor   16'8""   x  65'10"" FROM RETAIL TO TAKE-OUT RESTAURANT.     ADD NEW 300 SQ FT. MEZZANINE  ( irregular 14.25'  x  25.25') and (N) STAIRCASE.}}}"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46653	13041-10000-13654	24911 S WESTERN AVE	90717	15	039B193   649	7372017031	[Q]C2-1VL, [Q]P-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	33.79838	-118.30784	FA. FULL EVAC FOR RETAIL: SAVERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46654	17041-20001-00983	11826 W SHELDON ST	91352	6	198B169    54	2538003030	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM			PC Approved	04/18/2017 12:00:00 AM	ADDRESS	34.24137	-118.39062	4/18/2017Changes to an approved set of plans.  Relocate distribution board inside electrical room.  (((service upgrade 1600amp feeding (2) 800 amp sections.  loads to be future. plan check for power only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46655	16041-20001-00585	1818 S GLENDON AVE	90025	5	129B153   554	4321001***	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Approved	02/12/2016 12:00:00 AM	ADDRESS	34.04953	-118.43499	[[[2/12/16 Changes to approved PV2 plans. Changes to match installation. Delta 2 changes only.]]]]]PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(31) SOLARWORLD PLUS SW 260 WATTS(31) P300 OPTIMIZERS (1) SOALREDGE SE7600 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46656	15041-10000-23543	6318 N CALLICOTT AVE	91367	3	177B093   131	2035016005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.18468	-118.6368	PV 1 INSTALL A NEW 12925 KW DC ROOF MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME (47) MODULES REC SOLAR REC275TP  (1) INVERTER SOLAREDGE SE 11400A-US 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46657	17041-20001-14446	1302 S LA BREA AVE	90019	10	129B181   842	5070001018	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			PC Approved	03/09/2018 12:00:00 AM	ADDRESS	34.04983	-118.34395	3/9/2018changes to an approved set of plans.  changes to lighting fixtures and relocation of electrical equipment.  no change in load.  this is plan check only.    (((Plan check for power and energy. Build out common areas (stairs, parking, etc.) for new 2-story commercial retail building over one level of subtarranean parking. 5,000A service. 107,978sqft indoor area, 30,644 outdoor area.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46658	13041-20000-33612	19408 W LONDELIUS ST	91324	12	195B117   145	2783027015	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.22976	-118.55604	"Install new outdoor lighting.  Sign to installed on a separate application to be approved by ""Building"". ""COMPLY WITH DEPARTMENT ORDER effective date 1/27/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46659	13041-10001-35742	5840 W CENTINELA AVE	90045	11	102B169    68	4103005033	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	33.97633	-118.38267	Plan check for power and energy. Tesla repair center. new IT equipment room/office and lithium battery repair room.Nonhazardous per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46660	16041-20000-23562	18000 W DEVONSHIRE ST	91325	12	204B125   194	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.25698	-118.52508	Plan check for Fuel Cell System 1574 kW(1.6 Mega Watts) located on parking lot of Medtronic consist of 5 fuel cells(210kW) and 2 fuel cells (265kW) connected to (2)5,000A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46661	19041-10000-04491	735 S FIGUEROA ST #126	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.04878	-118.26079	PLAN CHECK FOR TITLE 24 ONLT T.I FOR RESTAURANT TOTAL EFFECTED AREA 914 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46662	11041-20000-26085	5251 N VINELAND AVE	91601	2	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM			PC Approved	12/07/2011 12:00:00 AM	ADDRESS	34.16639	-118.37064	ENERGY PLAN CHECK OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46663	18041-10001-08134	4745 W WASHINGTON BLVD	90016	10	126B181  1078	5071025004	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM			PC Approved	06/27/2018 12:00:00 AM	ADDRESS	34.03999	-118.34301	(This is plan check only) Plan check for T24 only, TI on existing commercial space, total area: 2424 sq.ft. Permit for circuits is covered under the express permit# 18041-10000-08134	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46664	15041-10001-16340	10630 N SEPULVEDA BLVD 1ST, 2ND,-ROOF	91345	7	207B145   393	2649011021	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Approved	12/11/2015 12:00:00 AM	ADDRESS	34.26357	-118.46694	(((CHANGES MADE TO APPROVED SET. REMOVED DUCT DETECTORS AND RELOCATED TO SECOND FLOOR. ADDED 1 SD TO ELEVATOR LOBBY. NUMBER OF DEVICES HAS NOT CHANGED, THIS IS A PLAN CHECK ONLY APPLICATION)))New fire alarm system replacement, Scope include (1) fire alram panel,  (1) power supply and (74) fire alarm devices. Note; portion permit fee is paid under express permit #: 15041-10000-16301 (((FIRE ALARM SYSTEM ADDITION)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46665	19041-30000-06869	800 S HARVARD BLVD	90005	10	132B193   622	5093022012	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2124.20	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	34.05747	-118.30403	Plan check for a fire alarm system for a 6-story, 131-unit apartment building. Fire alarm consists of (1) FACP, (11) RPSs, (1) annunciator, and (408) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46666	19041-20000-14584	1409 N HOBART BLVD	90027	13	147A195   156	5544033020	R3-1XL	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	07/25/2023 12:00:00 AM	ADDRESS	34.09699	-118.30591	Addition of a 4-unit 3-story to an existing apartment building.  800A 240/120V 1ph-3w service.  Plan check for power and energy.B#19014-30000-01511	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46667	18041-20000-00680	19351 W HATTERAS ST	91356	3	174B117    78	2153034031	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.17594	-118.55521	PV1.  Install 7.67 kW roof mounted grid tied PV system.  (26) modules with string inverter and energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46668	16041-20000-26777	7172 W HAWTHORN AVE	90046	4	147B181   449	5548011061	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.09956	-118.34638	permit fees $0.00 by state senate bill no.1222Install a roof-mounted solar array on an Apartment building. Interconnect with a 400A MSP. Derating main breaker from 400A to 250A. 40kW ungrounded system [4*10kW]. (176) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46669	14041-20000-07874	13023 W ARROYO ST	91340	7	216B161    31	2514002048	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.29134	-118.41681	Install new refrigeration equipment system.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46670	18041-20000-01305	515 S FLOWER ST 6th flr	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	ti to an existing commercial building (highrise).  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46671	18041-20000-33425	20653 W BEECH CIR #328	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.29266	-118.58412	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46672	18041-20001-19193	1926 E 7TH PL	90021	14	124-5A217 332	5166017005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.03343	-118.23298	10/10/2018 Changes to an approved set of plans. Lighting system has been revised. Now includes theater lighting. All changes have been reflected onto the Title 24 compliance forms. A panel has been added to comply with disaggregation requirements.*****Previous Work Description*****Change of use from warehouse to theater and 400A service upgrade.  Place of assembly exceeding 100 occupants.  Building permit under 17016-10000-03724.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46673	18041-10001-43122	11916 W PICO BLVD	90064	11	123B149   970	4259039054	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Apartment			11/09/2018 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.02999	-118.44856	Plan check for a PV1 23.4KW AC / 28.3 KW DC roofmounted system with (2) inverter, (82) modules, and (41) optimizer interconnecting through a new load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46674	15041-20000-00332	5900 W WILSHIRE BLVD Suite 1540	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for energy only. TI to an office on the 15th floor of a high rise office building. New lighting (incl. emergency) and receptacles. 2,192sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46675	18041-20001-13443	22420 W VANOWEN ST	91307	12	180B101    36	2038028032	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.19357	-118.61551	Fees for expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46676	18041-10000-19818	2323 W OLYMPIC BLVD	90006	1	130-5A201 125	5136015027	C4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.0525	-118.28312	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46677	12041-10001-05337	22284 W BUENAVENTURA ST	91364	3	168B101   680	2170003015	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	34.15532	-118.61277	Revision to approved plans for a 8.2KW CEC AC Photovoltaic system. Revsion consist of installing 2- 4.2KW transformerless inverters, combiner boxes, and subpanel. Number of modules remains the same.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46678	17041-10000-21976	7217 N BERNADINE AVE	91307	12	183B093    86	2027011016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.20094	-118.6388	rooftop solarPC FOR PV SYSTEM USING 31 MODULES. USING MICROINVERTER ENPHASE 280W.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46679	18041-10000-38344	3443 S SEPULVEDA BLVD	90034	5	117B157   113	4251015006	C2-1VL, R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.01969	-118.4228	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46680	16041-10000-32149	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for a 1st time tenant for bakery shop (eBar) in Nordstrom. Total area: 1,000 sq ft. Tittle 24 is included on the core/shell plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46681	15041-10000-11063	11620 W WILSHIRE BLVD # 610	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM			PC Approved	04/14/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	ALTERATIONS IN OFFICE SPACE PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46682	18041-10000-46424	633 W 5TH ST STE 3400	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	TENANT IMPROVEMENT WORK IN EXISTING OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA  EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46683	18041-20001-38741	23130 W VENTURA BLVD	91364	3	171B097   747	2042006077	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	9304.01	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM			PC Approved	11/13/2019 12:00:00 AM	ADDRESS	34.16312	-118.62954	Plan review per inspector correction notice.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46684	11041-10000-10497	1800 S MAIN ST	90015	9	123A207   102	5127024009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/23/2011 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.03196	-118.26368	NEW FIRE ALARM SYSTEM FOR A 2-STORY NIGHT CLUB.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46685	13041-10000-35542	2065 N SYCAMORE AVE	90068	4	150B181   298	5549024043	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Expired	02/29/2016 12:00:00 AM	ADDRESS	34.10779	-118.34126	PV1, Install 5.75 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (23) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46686	18041-10000-40249	7201 W MELROSE AVE	90046	5	141B181   552	5525011012	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.08362	-118.34647	TITLE -24 ONLY. CHANGE OF USE FROM (E) RETAIL TO (N) TAKE-OUT RESTAURANT (COFFEE SHOP).SCOP OF WORK INCLUDE NEW LIGHTING AND RECEPTECLES. EXISTING PANEL BOARD. TOTAL SQ-FT 1022.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46687	16041-20001-01909	19100 W NAPA ST	91324	12	192B121    83	2784007005	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM			PC Approved	01/29/2016 12:00:00 AM	ADDRESS	34.22631	-118.54949	Expedited per cusomer request.PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel. (42) Canadian Solar CS6pp Modules(1) Fronius Primo 7.6 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46688	11041-20000-04009	6803 N CEDROS AVE 2ND FLR	91405	6	183B149   700	2219020800	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	06/09/2011 12:00:00 AM		Permit Finaled	08/23/2011 12:00:00 AM	ADDRESS	34.19418	-118.45322	PLAN CHECK T24 ENERGY/EMERGENCY FOR NEW LIGHTING IN MECHANICAL ROOM NEW ON 2ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46689	18041-20000-46719	18951 W ARMINTA ST	91335	3	189B121   320	2104005026	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.21393	-118.54671	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46690	14041-10001-15808	11054 N TAMBERLY LANE	91042	7	210B197   581	2552046016	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	34.2699	-118.29257	Expedited RSES plan check per applicant request.{{PV1, Install 6.885 KW DC roof-mounted solar array on a two-story house, interconnect with main service panel. Transformerless inverter. With optimizer.(27) Modules: Trina Solar # TSM-255pa05.18(1) Inverter: SOLAREDGE #SE6000A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46691	16041-20002-19402	3239 N PASADENA AVE Unit C	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/30/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	Revisions to approved set.  Change of inverter from central inverter to microinverters.  (((PV2.  Install 2 kW DC roof mounted PV system.  (7) modules with (1) 3 kW transformerless inverter with power optimizers.  3 of 3 PV systems proposed for property submitted concurrently.Zoning clearance obtained under 16041-20000-19398)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46692	11041-20000-23814	1241 W WASHINGTON BLVD	90006	1	126A201   140	5135010034	[Q]C2-1	Central	Westlake	Pico Union		2217.10, 2243.10	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	PIN	34.04015846	-118.28384255	T.I.  New 800 amp service for existing retail space.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46693	13041-20000-08694	2706 W WILSHIRE BLVD basement	90057	1	133-5A201  94	5141011016	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.06093	-118.28296	Phase three of flood repair damage. Addition of AC units.Install circuits and outlets for repaired building.  Basement only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46694	19041-20001-00460	505 N MARINE AVE 1-17	90744	15	030B205  1040	7418004009	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	33.7759	-118.2636	Revisions to approved electrical design - approval for clouded portions only.  Load calculation details modified to reflect revised electric washer/dryer details.  Central water heating on roof omitted.  Change of engineer.   (((FULL PLAN CHECK FOR A NEW 2 STORY 17 UNIT LOW INCOME APARTMENT BUILDING, 100% AFFORDABLE HOUSING PROJECT. SCOPE INCLUDE 800-AMP 120/240V 3-PHASE 4-WIRE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46695	16041-10000-11714	7257 N RESEDA BLVD	91335	3	186B125   918	2118029024	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.20278	-118.53628	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COIN OPERATED LAUNDRY BUILDING. SCOPE INCLUDES NEW LIGHTING AND A NEW 400A MAIN DISTRIBUTION PANEL DUE TO FIRE DAMAGE. TOTAL AFFECTED AREA IS 2800 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46696	17041-20002-09901	12601 W PIERCE ST Bldg 16	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	12-19-2018 Changes to an approved set of plan, Changes include addition of sub-panel. All changes has been clouded as delta 1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46697	17041-10001-43520	5054 S VERMONT AVE	90037	9	111B197  1346	5018018019	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Info Complete	01/17/2019 12:00:00 AM	ADDRESS	33.99673	-118.29133	"Delta ""C"",""D"" and ""E"" changes to approved plans. Plan check for power and energy for approved set # 17041-20000-43520. changes are clouded include new crkts and connect loads to MSA original scope:TI/Change of use of portion of building from child care facility to office, new 1st and 2nd floor addition to (E) office. New 600A 120/240V 3ph 4w service. T24 area - 11,022sqft."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46698	14041-10001-31545	6344 N TOPANGA CANYON BLVD UNIT 1010	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	((8/6/2015))changes to an approved set of plans.  Changes noted delta 7.  Changes include addion of two panels(k, k1) and additional circuits.T. I. FOR RESTAURANTPART OF WESTFIELD DEVELOPMENT. FULL PLAN CHECK FOR POWER AND ENERGY. ASSIGN TO ANTHONY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46699	10041-10001-06090	4852 W MELROSE AVE	90004	13	141B193   594	5521004016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	PIN	34.08337382	-118.3060894	PLAN CHECK ONLY FOR ENERGY.  MODIFICATION TO T-24 ONLY FOR PREVIOUSLY APPROVED PLAN, REQUESTED BY APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46700	15041-10000-26329	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	07/12/2017 12:00:00 AM		Issued	07/12/2017 12:00:00 AM	PIN	33.92817449	-118.43220714	PC FOR POWER, SCOPE OF WORK INCLUDES THE INSTALLATION FOR (8) 15 HP 480 V, 3PHASE RECIRCULATION PUMPS, (1) 480 V, 3PHASE MCC, AND NEW CIRCUITS ADDED IN THE  HAZARDOUS LOCATIONS-CLASS1 DIVISION 2. . IDO FUND # 761. UNIT#78450000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46701	08041-20001-01789	4700 W JEFFERSON BLVD	90016	10	120B181   799	5046010028	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM			PC Approved	09/29/2010 12:00:00 AM	ADDRESS	34.02529	-118.34722	Plan check only. Revision to approved plans. Changes to T-24 calculation and lighting load in panel schedule.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46702	17041-10000-02159	7501 W SUNSET BLVD	90046	4	147B177   986	5550010022	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.0982	-118.35302	T-24, PC FOR ENERGY ONLY. CHANCE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1488 SQ. FT.   B#17016-10000-00399	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46703	18041-10000-38026	14433 W EMELITA ST	91401	4	174B149    98	2245004025	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.17682	-118.44768	REMOVE OUTDOOR HID FIXTRES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46704	14041-10000-34957	11163 W SANTA MONICA BLVD	90025	5	129B153   838	4324035024	M1-1	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM			PC Approved	01/23/2015 12:00:00 AM	ADDRESS	34.04748	-118.44561	Energy plan check for  a car (Tesla) service center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46705	19041-10000-04047	943 S SANTEE ST SUITE #3	90015	14	126A209   160	5145016014	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.03937	-118.25467	T24 ONLY FOR EXISTING RESTAURANT SPACE, TOTAL SQFT'G = 1644	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46706	14041-10000-35146	700 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM			PC Approved	01/06/2015 12:00:00 AM	PIN	33.94153561	-118.3984113	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46707	11041-10000-24383	982 E LAKE ST BLDG 4-4	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.0011	-118.46065	Lincoln Place Apartment Building Project.  New 2-story apt. building with 6 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46708	14041-10000-17217	13269 W WEIDNER ST	91331	7	210B157   135	2534002034	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.27415	-118.42286	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 4900 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46709	15041-20000-23378	11935 W ELKWOOD ST	91605	6	189B165   718	2310020011	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.21311	-118.39342	pv1 sfd. total system size 5kw ac using 21 modules total.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46710	12041-10000-17444	10201 W PICO BLVD Bldg 101-3rd Floor	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM			PC Approved	07/26/2012 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check for energy and emergency lighting. Fox. 5th Floor. 1285 sqft. ALL LIGHTS ARE ALSO CONNECTED TO EMERGENCY. Building 101, 3rd floor. (Phase 3).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46711	12041-10000-27254	5951 W 76TH ST	90045	11	102B169   404	4104011005	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	33.97233	-118.38769	PV1 SOLAR INSTALLATION. ROOF MOUNTED 4.16KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46712	13041-10000-09454	882 W SUMMERLAND AVE	90731	15	018B197   202	7447015008	R2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	33.74773	-118.2962	PV1 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 2.88 KW. TRANSFORMERLESS. 12 MODULES AND 1 INVERTER. [INVERTER: SOLAR EDGE SE3000A-US] [PV MODULE: TRINA SOLAR TSM-240PC05/PA05.18].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46713	16041-20000-40252	720 S HOBART BLVD	90005	10	132B193   425	5093018023	R3-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.05889	-118.30517	permit fees $0.00 by state senate bill no. 1222Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 31.7kW (6kW*4+7.7kW) ungrounded system. (116) 340W pv modules. **no fees	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46714	14041-10000-19254	16001 W CHATSWORTH ST PV1	91344	12	207B141   356	2667026022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.26478	-118.4807	PV1. 3.9 KW DC ROOF MOUNTED PV SYSTEM.  transformerless (12) MODULES (1) INVERTER. PLANCHECK ONLY, PERMIT PREVIOUSLY PULLED UNDER 14041-10000-12615.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46715	19041-20001-28656	11152 N LANGMUIR AVE	91040	7	210B193   263	2551038016	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.27205	-118.30854	Revisions to approved set - plan check only.  Change of backup system from full house backup to partial backup.  (((addition of (1) ESS rated 5KW to an existing pv system.  plan check for power only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46716	15041-10000-01948	5309 E BORLAND ROAD	90032	14	138A235   104	5221005018	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.07305	-118.16846	APPLICANT HAS BEEN TOLD OF ONLINE PROCESS. PV1 3.18KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(12) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22-IG]}]. [(12)modules: {sun edison silvantis F-series F265CzD-3y}] . Panel upgrade under separate permit.    The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46717	14041-20000-20434	16056 W SUNBURST ST	91343	12	195B141    88	2672004011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.23443	-118.48249	Standard Plan for 4.335 KW PV1 roof-mounted system including: (1) Power-One PVI 3.6TL inverter and (17) Trina Solar  TSM-255 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46718	18041-20001-39964	5104 E RANGE VIEW AVE	90042	14	156A225    57	5479027017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.12352	-118.20382	11-08-2018 Changes to an approved set of plan, Changes include relocated disconnect near by main panel.Plan check onlyFee $0 due to california senate bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46719	15041-20000-27891	11659 N FLORENCIA WAY	91326	12	213B109   700	2701076058	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.28388	-118.5851	Installation of new roof mounted solar PV array.  Total system size  = 7.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46720	13041-10010-26820	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			04/06/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	33.97574	-118.39042	((4/6/2016))CHANGES TO AN APPROVED SET OF PLANS.  RELOCATING EXISTING LIGHTING IN TRASH ROOM 2A NOTED DELTA 10.  THIS IS PLAN CHECK ONLY.New 218-unit apartment building at Howard Hughes Center.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46721	16041-20000-25684	16000 W VENTURA BLVD #480	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.15584	-118.48164	Plan check for Title 24 existing commercial high rise office remodel. All new lights and existing circuit. Total area: 1,056 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46722	15041-10000-04599	9750 N SAN FERNANDO ROAD	91352	6	201B165    92	2537020001	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.2478	-118.40183	Energy plan check for replacing retrofit kits from existing to LED lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46723	16041-20000-01820	3701 W STOCKER ST SUITES 104-105	90008	8	114B185   650	5032022018	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM			PC Approved	01/19/2016 12:00:00 AM	ADDRESS	34.00699	-118.33765	TI to existing commercial building. Plan check for energy only. Adding new lighting including emergency. Total sqft. 1012.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46724	15041-20000-29451	6220 N TOPANGA CANYON BLVD K990	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Closed	04/05/2016 12:00:00 AM	ADDRESS	34.1841	-118.60553	PLANCHECK FOR POWER AND ENERGY. KIOSK  (UNIT K990) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46725	12041-20000-22926	9340 N OWENSMOUTH AVE	91311	12	198B105    77	2746014043	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM			PC Approved	09/26/2012 12:00:00 AM	ADDRESS	34.24067	-118.60169	Plan check for energy and emergency lighting. Lobby area. 1291 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46726	13041-10001-36024	6955 N RUBIO AVE	91406	6	183B137   292	2225006036	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.19711	-118.49576	Expedited RSES plan check per applicant request.{{PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (23) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46727	16041-20000-44090	857 N HAYWORTH AVE	90046	5	144B177   485	5529021047	R3-1	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			12/15/2016 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	05/24/2022 12:00:00 AM	ADDRESS	34.08709	-118.36295	new apartment building 800amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46728	19041-10000-53464	11031 N GLENOAKS BLVD	91331	7	210B161   622	2536018018	[Q]CM-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	34.27024	-118.40836	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46729	12041-10000-15360	11700 W NATIONAL BLVD	90066	11	120B153  1083	4250001026	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	PIN	34.02218411	-118.43889497	T. I. - Beauty Salon + Nail & Spa. P/check for compliance with Calif. energy efficiency standards and emergency egress illumination.(CHANGE OF USE FROM RETAIL TO NAIL SALON ( 27' X 70') ; INSTALL INTERIOR NON BEARING WALLS; NO CHANGE OF PARKING)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46730	13041-10000-23050	529 N SLOAT ST	90063	14	127-5A227  88	5178017009	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.0448	-118.19747	PV1.  Install 2.2 kW AC roof-mounted solar array, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46731	17041-30000-45049	6060 W CENTER DR 3rd Floor	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	33.97602	-118.39073	Plan check for Title 24 only. Project site is the 3rd floor of an existing commercial building. Project scope is a tenant improvement to partial corridors. Total lighting area = 751 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46732	16041-10002-37707	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to an approved set of plan. Plan check for power only to the master plan, place of assembly. A2 Occupant Load: 1308Additional 3 transformers rated at 75KVA changes are under delta 2, clouded area.Energy Plan check was done on 16041-10000-37707Note to inspector: please verify circuits installed per permit pulled.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46733	13041-10001-12093	12304 W SANTA MONICA BLVD	90025		126B145   865	4267031001							Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.03925	-118.46584	Supplemtal, changeing notes in regards to type of clinic and changing from one inverter to 4.  This plan check only.  Permit is existing.  System is 56 KW total.Prev. Submittal<<<<<<PV2 ROOFMOUNT on 3 STORy building. NONSTandarD plan.  64kw ballasted system. 248 modules @ 260 W (Talesun tp660M-260W).  XFMR inverter solectria (model 56kw) .>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46734	18041-10001-01113	11601 W WILSHIRE BLVD #100	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Change to approved set by updating the lighting on the floor plan. All changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46735	12041-10000-07243	1073 E AMOROSO PL	90291	11	111B149  1168	4242005028	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2012 12:00:00 AM	04/18/2012 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	33.99756	-118.45491	PLAN CHECK NEW 6.21KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46736	15041-20001-11889	12457 W OSPREY LANE Unit 1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	ADDRESS	33.97937	-118.41024	Expedite per applicant request********Plan check for PV1 roof mounted  system 8 modules (SUNPOWER MODULES SPR-230NE-LK-D) and 1 inverter(SB3000TL -US-22)PV clearance shall apply to Unit #2 and #3 of address 12457 Osprey Lane	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46737	10041-10000-23576	10250 W SANTA MONICA BLVD store-480	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	03/15/2011 12:00:00 AM		Permit Finaled	05/25/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	NEW BJ RESTAURANT AT THE CENTURY CITY MALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46738	17041-20000-01693	7672 N COLDWATER CANYON CT	91605	2	186B161   647	2303020078	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Issued	02/06/2017 12:00:00 AM	ADDRESS	34.2102	-118.41475	PV1.  Install 3.78 kW roof mounted grid tied PV system.  (12) modules with (1) 3.0 kW rated central inverter.  (E) 3 kW rated system installed on site.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46739	12041-10001-09560	9340 N OWENSMOUTH AVE	91311	12	198B105    85	2746014043	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	03/14/2013 12:00:00 AM	ADDRESS	34.24067	-118.60169	PV-2 Plan check only. Plan check for revision to approved plan. Field changes. Plan check new 100.8KW roof mounted Photovoltaic System. Modules located on roof  of warehouse building (9410 Owensmouth Ave.) connecting to Inverter located in main office building (9340 Owensmouth Ave.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46740	19041-10000-31716	22234 W MARLIN PL	91303	3	183B101   477	2024035020	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.19669	-118.61158	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 5.00KVA PV1 SYSTEM CONISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 17 MODULES USING P320 OPTIMIZERS AND ESS(TESLA POWERWALL) NOTE : SFD HAS AN EXISTING PV SYSTEM	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46741	11041-10000-12772	4621 W SANTA MONICA BLVD	90029	13	144B197   710	5542029024	C2-1D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	34.09101	-118.29003	TI IMPROVEMENT TO AN EXISTING MEAT MARKET.  PLAN CHECK IS FOR ENERGY WITH EMERGENCY CIRCUIT ONLY, OTC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46742	17041-20000-28087	12257 N LIMA WAY	91342	7	219B149   933	2611046025		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.29404	-118.45593	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46743	13041-10000-24509	8527 N SEPULVEDA BLVD	91343	6	192B145   119	2654020015	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.22544	-118.46799	NEW 3-STORY MEDICAL FACILITY. PLAN CHECK POWER AND ENERGY. UNDERGROUND 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46744	17041-20000-09790	9132 N FOSTER LANE	91311	12	198B101   336	2727024001		North Valley			YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.23662	-118.60697	pv1install roof mounted pv system sized 2.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46745	17041-20000-08930	10250 W CONSTELLATION BLVD 7th flr	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	ti to an existing commercial building cooridor seventh floor. plan check for energy and em lighing only.  total square footage 1565.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46746	18041-20000-13694	4114 N VANTAGE AVE	91604	2	165B165  1163	2367014027	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			04/13/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	07/05/2020 12:00:00 AM	ADDRESS	34.14533	-118.39744	Plan check for power and energy for new appartment building 18 units 4 story. Total area: 17,524 sq ftFire alarm variance has been filed.B#17041-20000-05144	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46747	13041-10000-17966	10380 W WILSHIRE BLVD 1-69	90024	5	135B157   141	4327013***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Issued	08/01/2013 12:00:00 AM	ADDRESS	34.06719	-118.4277	Replacement of existing fire alarm control panel in highrise building with upgraded panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46748	16041-20001-12826	6600 N TOPANGA CANYON BLVD STE 1008	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for energy only.  New lighting system for front space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46749	15041-20000-41762	221 N FIGUEROA ST 15TH FLR	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.05882	-118.25099	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (15TH FLOOR OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING ON THE 15TH FLOOR.  TOTAL AREA IS 17397 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46750	16041-20000-31809	24211 S PRESIDENT AVE	90710	12	039B193    63	7439013045	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	33.80612	-118.30388	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46751	17041-10000-03713	2041 W BEVERLY BLVD	90026	13	136-5A205 348	5157021001	C2-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	PIN	34.06673725	-118.26965116	NEW SITE LIGHTING FOR BUILDING STILL UNDER CONSTRUCTION. PC FOR T24 ENERGY ONLY. THIS SITE LIGHTING SHALL BE SEPARATE PERMIT FROM BUILDING ELECTRICAL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46752	18041-20000-00563	879 W 190TH ST 6th Floor	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	33.85951	-118.28963	Tenant improvement to restrooms on 6th floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46753	17041-20000-33184	9036 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	PIN	34.23382129	-118.55266297	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 4,918 sq. ft.Note: Building application has been generated under 17016-20000-26991	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46754	19041-10000-42441	10549 N NEVADA AVE	91311	12	207B101   184	2723015065	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.26207	-118.60966	(E-PLAN)NEW ROOF MOUNTED SOLAR PV1 SYSTEM WITH AN EXISTING 200 AMP SEVICE WHICH INCLUDES 34 MODULES (SLA320M), 1 INVERTER (SE10000H-US), AND PV OPTIMIZER (SOLAREDGE P320). SYSTEM SIZE: 10.88 kW .Fees $71.99 due to California Senate Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46755	14041-10000-28120	2510 W HYDE PARK BLVD	90043	8	105B189  1156	4007016001	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	33.98272	-118.32086	Title 24 plan check only. Area = 10,080 sq. ft.Removal of HIG light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46756	17041-20001-12060	7501 N GLENOAKS BLVD	91504	2	186B181   296	2401042013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.04	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	34.20677	-118.34209	2/23/2018chnages to an approved set of plans.  changes to reflect field conditions.  changes noted delta 1.this is plan check only.  no new equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46757	13041-20000-22796	7920 N CHASTAIN AVE	91335	12	189B129   695	2101029004	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.21425	-118.52365	pv1 single family dwelling. total system size 3.6 kw using 17 modules. enphase m215 microinverter. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46758	11041-20000-20407	7060 W HOLLYWOOD BLVD 1st floor	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/26/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.10137	-118.34379	Remodel of bathroom and electrical room light fixtures on the first floor of high rise building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46759	12041-10001-29911	"12722 W MILLENNIUM BLDG ""B"""	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			01/22/2014 12:00:00 AM			PC Info Complete	01/22/2014 12:00:00 AM	ADDRESS	33.9761	-118.41564	REVISION TO APPROVED PLANS. DELTA 10 - ADD NEW CENTRAL WATER HEATING, CIRCULATING PUMP FOR BUILDING AND REMOVE GAS WATER HEATER FOR DWELLING UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46760	12041-10000-10610	813 S UNION AVE	90017	1	130-5A205 153	5142017004	R3-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Apartment			05/09/2012 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.05195	-118.27271	New 3-story apartment building w/ parking garage at first floor.  New 800A service and 9-units.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46761	18041-10000-36986	13101 W WELBY WAY	91606	2	180B161   126	2326010008	R1-1	South Valley				1234.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Closed	06/17/2019 12:00:00 AM	ADDRESS	34.19308	-118.41838	Install new PV1, rooftop solar system in (E) SFD. System size at 10.890 kW DC / 10 kW AC. Scope includes: (33) modules with (33) optimizers P400, (1) SE10000 central srting inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46762	16041-10001-26819	811 W WILSHIRE BLVD	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.04973	-118.2584	PC FOR POWER UNDER PHASE II ONLY.  DUE TO DAMAGED EQUIPMENTS (Replacing all switchgears over 5000 AIC  rating), load demand is remain the same.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46763	12041-10000-23846	7900 S YORKTOWN AVE	90045	11	099B169   857	4107011017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2012 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	02/04/2013 12:00:00 AM	ADDRESS	33.96615	-118.38932	INSTALL A NEW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46764	14041-20001-08554	20470 W NASHVILLE ST	91311	12	210B109   161	2707026019	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.26998	-118.57907	PV1 10KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(2) inverters: {PVI-3.6-OUTD-US , PVI-3.6-OUTD-US }]. [(40)modules: {Canadian Solar {CS6P 250P}}]     'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46765	19041-20000-53653	5533 S EA WAY 3rd-4th flr	90094	11	102B157   295	4211022025	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Permit Finaled	09/02/2020 12:00:00 AM	ADDRESS	33.97374	-118.42896	FULL PLAN CHECK FOR POWER AND ENERGY.  ADD NEW PANELS, EQUIPMENTS, AND LIGHTS ON 4000 AMP EXISTING SERVICE. FIRST TIME TENANT TO THE 3RD AND 4TH FLOOR. TOTAL SQ. FT.  59,351 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46766	15041-10000-05573	1123 S BOYLE AVE	90023	14	123A221   272	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.03071	-118.22047	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 7968 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46767	16041-10000-18139	450 S WESTERN AVE #205	90020	10	135B193   649	5503014020	R3-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	T24 ENERGY ONLY. PC FOR NEW LIGHITNG IN SHOE STORE. RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46768	14041-20000-31104	1680 N VINE ST SUITE 700	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.10133	-118.32648	TI TO AN EXISTING HISTORICAL BUILDING.  ADDING NEW LIGHTING NEW CIRCUITS TO SUITE 700.PLAN CHECK FOR ENERGY TITLE 24.  2841 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46769	16041-10001-32896	903 W OLYMPIC BLVD	90015	14	129A207   293	5138005036	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM			PC Approved	11/07/2016 12:00:00 AM	ADDRESS	34.04577	-118.26611	11/07/16Changes to an approved set of plans. All changes are clouded under detla 1. Changes include revising single line diagram to reflect what is on the field, revising track lighting calculations, and revising floor plans.Note: Permit is paid under PCIS#16041-10000-32896(((((((((((T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RESTAURANT TO RETAIL SPACE. TOTAL AFFECTED AREA IS 5519 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46770	16041-10000-24118	1331 S MENLO AVE	90006	1	129B197  1232	5056001041	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.04633	-118.29067	PV1, rooftop solar installation on SFD. Residential consists of 2 buildings, each building has its own main service. (1) SE5000A-US     (19) CS6P-260P     System is Using SE-P300**Note to inspector: Please verify the physical location of equipments in driveway.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46771	17041-10000-35340	600 S SPRING ST r2	90014	14	129A211   252	5144001020	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Info Complete	10/04/2017 12:00:00 AM	ADDRESS	34.04568	-118.25098	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE. TOTAL AFFECTED AREA IS 1300 SQ. FT. B#17016-20000-27756	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46772	18041-10000-41033	134 E 56TH ST	90011	9	108B205   829	5101018022	R2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.10	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	33.99144	-118.27269	Plan check for 10KW AC/ 9.92 KW DC PV1 roofmounted system with (1) 10kw inverter, (31) modules and optimizer interconnecting through the load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46773	10041-10000-20286	15600 W ODYSSEY DR	91344	12	213B145    23	2605002011	(Q)C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM	11/05/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	34.28358	-118.47233	New Fire Alarm System in the building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46774	14041-20000-19519	10340 N GLORIA AVE	91344	12	204B141   176	2668016018	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.25875	-118.47922	Roof mounte PV system, total system size 8.67KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46775	17041-10000-46304	601 S WESTMORELAND AVE	90005	10	135B197  1004	5077009001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Issued	12/27/2017 12:00:00 AM	ADDRESS	34.06347	-118.2886	REPLACE OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46776	19041-10000-10982	301 S AVALON BLVD	90744	15	027B205   619	7440009911	PF-1D	Harbor	Port of Los Angeles, Wilmington - Harbor City	Wilmington		9800.31	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	09/15/2021 12:00:00 AM		Permit Finaled	05/23/2024 12:00:00 AM	ADDRESS	33.76771	-118.26109	Full plan check for a new construct a public restroom building with 6 single user stalls and new electrical room supplied from a larger service from other building..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46777	12041-10000-25576	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM			PC Approved	10/25/2012 12:00:00 AM	ADDRESS	34.05956	-118.41375	Ti on the 15th floor, office Bldg, suite#1500. EPC is for T24 & emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46778	18041-10000-12752	6111 S GRAMERCY PL	90047	8	105B189   843	6001012028	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.98411	-118.31358	Replace old Fire Alarm Devices with new; replace control panel and 10 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46779	16041-10000-43483	14622 W SHERMAN WAY	91405	6	183B149   799	2219007033	(T)(Q)RAS3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Issued	12/12/2016 12:00:00 AM	PIN	34.19982904	-118.4516567	PC FOR NEW 800A 120/208  SERVICE UPGRADE TO EXISTING PARKING STRUCTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46780	13041-20000-35027	3240 S WASHINGTON BLVD	90291	11	108B149  1184	4237027034	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	PIN	33.99043601	-118.4482409	T24 FOR EXISTING OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46781	15041-20001-10695	13074 N GLADSTONE AVE	91342	7	222B157    66	2512010011	A1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	34.30784	-118.42451	Supplemental application for expedite fees only.Installation of new GROUND MOUNTED PV solar array.  Total system size = 5.5 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46782	11041-10000-20663	1422-1426 S ELKGROVE CIR BLDG 14	90291	11	111B149   425	4243001034	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.00135	-118.45796	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46783	10041-10001-05907	5555 E VALLEY BLVD Bldg 325	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Commercial			09/15/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Finaled	12/28/2010 12:00:00 AM	ADDRESS	34.07489	-118.16218	Addition of new panelboards, circuits, chillers  to a pharmaceutical manufacturing facility (Grifols Building 325). added new circuits to prev. approvrd set.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46784	11041-20000-12226	3285 W CASITAS AVE	90039	13	153B209   361	5436002024	MR1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.00	Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM	08/09/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.11661	-118.25229	New roof mounted P.V. system with 48.82KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46785	16041-20000-16862	20304 W STRATHERN ST	91306	3	189B113   512	2107025027	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.21546	-118.57563	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (34) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46786	19041-20000-33065	3650 N CODY ROAD	91403	4	162A147   220	2278027023	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.13669	-118.46359	Install 27 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46787	14041-10002-07239	11995 W BLUFF CREEK DR BLDG 4	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	((((4/27/2015))))CHANGES TO AN APPROVED SET OF PLANS.  ADDING 19 SENSORS PER PAGE MG 4.00.METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35606.BLDG PERMIT: 13010-10000-04244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46788	12041-10001-13528	2512 W HILL DR	90041	14	163-5A221  46	5682015001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	ADDRESS	34.1442	-118.21973	Modification to previously approved set of drawings.  Plan check is only for bus calculation for Photovoltaic system.  Load calculation for reducing the main breaker from 200 Amp to 150 Amp is to be verified by field inspector.             <<<<<Plan check for new 14.388KW roof mounted photovoltaic system for single family dwelling. Additional permit to upgrade service panel and branch circuit for monitoring system.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46789	16041-20005-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			05/08/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	SUPPLEMENTAL PLAN CHECK ONLYCHANGES TO AN APPROVED PLAN SET. CHANGES TO APARTMENT UNIT FEEDER SCHEDULE SIZES AND CALCS. CLOUDED DELTA 11 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46790	15041-20000-19536	7036 S LA TIJERA BLVD # 1 - 13	90045	11	102B173   327	4103009003	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			06/22/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	33.97412	-118.37509	PLANCHECK FOR A New 2-story, 13 unit apartment (Type VA) over basement parking garage (Type IA).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46791	11041-20000-17541	334 W 17TH ST	90731	15	012B201   486	7456024019	R2-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM			Reviewed by Supervisor	09/30/2011 12:00:00 AM	ADDRESS	33.72888	-118.28446	Enphase Microinverters photovoltaic system installed for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46792	10041-20001-05086	8359 N LAUREL CANYON BLVD	91352	6	192B165   367	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	05/18/2010 12:00:00 AM	ADDRESS	34.22299	-118.39669	Plan check T-24 Energy for change of use TI retail to beauty salon. Supplemental permit for additional ckts and new panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46793	18041-20000-22790	19542 W VALERIO ST	91335	3	186B117   703	2116003066	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.20423	-118.55936	Plan check for a PV1 roof-mounted PV system. System size is 9.6 kWdc/8.6 kWac. System consists of (1) 10 kWac rated inverter and (32) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46794	19041-10000-07680	14806 W CANTARA ST	91402	6	192B149   581	2210004014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.21923	-118.45577	PV1 SYSTEM 3.780 KW 12 MODULES ROOF MOUNTED, RESIDENTIAL. (12) MODULES AND (1) 3.8 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46795	19041-20000-43116	1337 W 12TH PL	90015	1	127-5A205 113	5137030024	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Issued	10/24/2019 12:00:00 AM	ADDRESS	34.04415	-118.27332	600A 240/120V 3ph-4w service upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46796	11041-20000-21199	115 N SOTO ST	90033	14	127-5A223 116	5183005010	R4-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Apartment			10/04/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Closed	11/07/2011 12:00:00 AM	ADDRESS	34.04422	-118.20967	UPGRADE SERVICE FROM 225 TO 600 A ADD WINDOW TYPE A/C	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46797	17041-20000-10933	21600 W OXNARD ST suite 1000	91367	3	177B105    84	2146006043	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.179	-118.6002	ti to an existing commercial building 10th floor.  adding new lighitng ew controls to existing panels.  plan check for energy only.  total square footage 10608.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46798	13041-10000-07536	5455 W WILSHIRE BLVD	90036	4	135B181   903	5508010025	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Expired	04/17/2015 12:00:00 AM	ADDRESS	34.06246	-118.34749	FIRE ALARM SYSTEM FOR COMMERIAL OFFICES. PART OF HIGH RISE. WORK TO BE DONE IS REPLACEMENT OF EXISTING FIRE ALARM CONTROL PANEL. ALL DEVICES EXISTING. PC FOR VOLTAGE DROP AND AMPACITY OF BATTERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46799	10041-10000-00750	1451 E 4TH ST 2nd fl	90033	14	127-5A219 339	5172020009	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.40	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	01/14/2010 12:00:00 AM		Permit Finaled	02/22/2010 12:00:00 AM	ADDRESS	34.04249	-118.22532	Tenant improvement on the second floor of an office buildingplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46800	18041-20002-24405	8422 N ZEILER AVE	91402	6	192B157   445	2637014045	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	11/21/2018 12:00:00 AM	ADDRESS	34.22368	-118.42536	Revisions to approved set.  Relocation of equipment and additional disconnect switch. $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.(((PV1.  Install roof mounted grid tied  PV system sized 7.6kW interconnected with MSP.    5 kW energy storage system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46801	18041-10000-49019	800 S FIGUEROA ST SUITE 620	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.04771	-118.26116	PLAN CHECK FOR TITLE 24 ONLY FOR - 4175 SF NON STRUCTURAL INTERIOR OFFICE TI TO COMBINE 2 EXISTING SUITES (620 AND 630) INTO ONE SUITE WITH NON BEARING PARTITION, MILLWORK, FINISHES AND CEILING - TOTAL AFFECTED AREA = 3192 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46802	16041-10003-15028	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			Permit Finaled	02/20/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	12/02/2016 Changes to an approved set of plans. Changes include add transformer at to feed panel to feed UPS and workstations from HMDF Panel  at LAX Airport Delta Terminal. Changes has been clouded  DCN-004{{{{{{{CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DCN - 002 ON PLAN. CLOUDED. CHANGES LNCLUDE USE OF BUSWAY 3200A AND REVISED FLOOR PLANS. PROVIDED UPDATED SHEETS AND T24}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46803	16041-10000-01628	10345 W PICO BLVD	90064		129B161   391	4315014014							Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM			Corrections Issued	01/15/2016 12:00:00 AM	ADDRESS	34.04761	-118.41527	Energy plan check for a tenant improvement (e) synagogue social hall. Scope include new lighting and receptacle with a total area of 2604-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46804	17041-10000-36246	731 S AVERILL AVE	90732	15	015B193   486	7459001023	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Issued	10/10/2017 12:00:00 AM	ADDRESS	33.73735	-118.30792	INTERIOR ALATERATIONS-REPLACE HID WITH LED LUMINAIRESTITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46805	15041-10000-02311	9030 S LOYOLA BLVD	90045	11	096B161   822	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	33.95663	-118.41787	PC FOR POWER AND ENERGY. DORMATORY AND ACADEMIC CLASSROOM BUILDING FOR OTIS COLLEGE OF ART AND DESIGN. TOTAL AREA  82,013SF. Fire alarm variance filed on 4/2/2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46806	14041-10000-03623	808 S OLIVE ST mainF-8F	90014	14	127-5A209  65	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Issued	02/10/2014 12:00:00 AM	ADDRESS	34.04479	-118.25694	permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. LESS THAN 400A. Inspector to verify if parking structure is HIRISE (no generator per applicant and no retrofit per list). TI TO MAIN and ELEV (floors 2-8) LOBBIES. (bldg: 14016-10000-00499). changes on plan: update in calcs for k type fixture and light C and D are LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46807	13041-20000-00354	9830 N KESSLER AVE	91311	12	201B113   331	2761017014	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.24882	-118.56767	Plan check for solar. PV-1. Uppal Residence. Ungrounded arrays.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46808	14041-20000-10922	9215 W VENICE BLVD 1st Floor	90034	5	120B165   446	4313021084	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.02659	-118.39373	Tenant improvement for existing building partial of the first floor.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46809	16041-20001-07883	7922 N HASKELL AVE	91406	6	189B141   117	2206001009	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.21463	-118.47476	EXPEDITE PER APPLICANT REQUESTInstall a roof mounted solar array on a Commercial building. Interconnect with a 600A MSP.System size: 20kW. (64) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46810	15041-10000-04900	20871 W PLUMMER ST	91311	12	201B109   357	2748023063	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.24289	-118.58708	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL  AREA 10144 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46811	16041-20000-37951	6929 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.19659	-118.49256	Upgrade electrical service - new 800 A 3ph/4w 120/240V service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46812	15041-20000-27454	20342 W ANDROWE LANE	91326	12	216B113   233	2701048032	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.29156	-118.57641	Plan check for PV roof mounted system. System size: 7.0kW with 24 modules and 1 inverter (7.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46813	12041-10000-01259	10259 N SEPULVEDA BLVD	91345	7	204B145   326	2660001012	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1097.00, 1098.00	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	34.25708	-118.46767	New addition to the retail portion of gas station.  New receptacles and lights.  PLAN CHECK ONLY for Energy, with Emergency.  (No suite number per applicant)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46814	17041-10000-44994	5200 N LANKERSHIM BLVD #410	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Issued	12/14/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	Design build. Energy plan check for an office T.I. Scope includes new light and equipment. Total area is 1,498 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46815	16041-20000-18147	1880 S CENTURY PARK EAST Suite 1011-1016	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.06144	-118.41437	TI to (E) commercial high-rise office space.  Plan check for energy.  Retrofit and relocation of (E) 2x4 fluorescents and associated lighting control devices.  3020 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46816	14041-20002-28799	11430 W BURBANK BLVD	91601	2	174B169   839	2350004033	C4-1, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			07/06/2016 12:00:00 AM			PC Info Complete	07/07/2016 12:00:00 AM	ADDRESS	34.17184	-118.38	"07-06-2016  CHANGES OF AN APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF GAME ROOM IN THE PARKING STRUCTURE AND BRANCH CIRCUIT FOR TV ADDITIONAL LOAD ON PANEL HM1, HP1 AND HP3. CHANGES APPLY TO DELTA ""D"" ONLY. **********PREVIOUS WORK DESCRIPTION************************NEW MIX USE APARTMENT BUILDING (2) SERVICES (1) 2000 AMP SERVICE (1) 1200 AMP SERVICE FIVE FLOORS WITH ONE UNDERGROUND PAKING LEVEL.  125 UNITS.  PLAN CHECK FOR POWEER AND ENERGY.Note: Variance to separate fire alarm plans submitted on 10/17/14."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46817	14041-10000-20124	5245 W SANTA MONICA BLVD	90029	13	144B193   695	5537009035	C2-1D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Apartment			07/25/2014 12:00:00 AM			Reviewed by Supervisor	08/07/2014 12:00:00 AM	ADDRESS	34.09094	-118.30401	Submittal fees are slightly reduced to match pre-cut check.  Add 6 fire alarm devices to final fees (285 total)New fire alarm system for 52 unit mixed use apartment building.  Total number of devices = 320	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46818	11041-20000-11900	1801 W OLYMPIC BLVD UPS	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake			2095.20	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.05046	-118.27663	PLAN CHECK POWER FOR UPS SYSTEM REPLACEMENT AND UPGRADE. NO NEW LOAD ADDED. NON-LIFE SAFETY EQUIPMENT.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46819	18041-10000-37323	8842 W FOOTHILL BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	05/18/2020 12:00:00 AM	ADDRESS	34.26086	-118.32514	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 75 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46820	14041-10000-00021	1107 S SAN JULIAN ST	90015	14	124-5A211 350	5145024***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.03569	-118.25345	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 1368 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46821	18041-20001-40875	4446 N TOBIAS AVE	91403	4	168A151   281	2265006006	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM			PC Approved	11/28/2018 12:00:00 AM	ADDRESS	34.15287	-118.45185	Expedite per applicant requestPlan check for PV roof mounted system, system size: 15.48KW DC, 13.76KW AC with 43 AC Modules connected to Sub-panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46822	17041-10000-44200	13832 W MULHOLLAND DR	90210	5	159B153   194	4385021023	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.13091	-118.43355	NEW 15.36KW(ac) ROOFTOP SOLAR FOR SFD. INSTALLING 48 PANELS 17.28KW(dc) AND 125A LOAD CENTER ON A SINGLE FAMILY HOUSE. INSPECTOR TO VERIFY THAT LOAD CENTER, DISCONNECT AND NEW 80A BREAKER HAVE TERMINAL LUG RATINGS AT 75DEG C.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46823	11041-20000-14319	1888 S CENTURY PARK EAST 15TH &19TH-FLR	90067	5	132B161    16	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	11/25/2011 12:00:00 AM	ADDRESS	34.06104	-118.41402	Plan check power and energy for interior tenant improvements in office building (15th & 19th floor ). Total load exceeds 400A installed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46824	14041-10000-12942	1759 N GLENDALE BLVD	90026	13	144A209   267	5423006033	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.08757	-118.2598	TI FOR EXISTING OFFICE SPACE. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46825	16041-20001-36609	4530 N BAKMAN AVE	91602	2	168B173  1009	2366001023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM			PC Approved	11/07/2016 12:00:00 AM	ADDRESS	34.15307	-118.37776	expedite per applicantpv1install roof mounted pv system sized 10.1kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46826	15041-20000-10063	8548 N CANTALOUPE AVE	91402	6	192B153    74	2637031016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.2263	-118.43622	Plan check for PV1 roof mounted system with 3.6kW(PVI-3.6-OUTA-US-A Inverter) with 16 modules(Hyundai HIS-M250-RG Modules)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46827	14041-10000-24000	2006 S MATEO ST	90021	14	120A217   205	5167012015	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.0216	-118.23254	Plan check for title 24 in an open area of a commercial/industrial working building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46828	11041-10000-12698	8500 W BEVERLY BLVD # 693	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	REMODEL OF EXISTING RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46829	15041-10000-03534	21230 W LASSEN ST	91311	12	201B105    83	2746004018	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.24983	-118.59483	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 23500 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46830	14041-20000-00092	6430 W SUNSET BLVD #1575	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	Change to lighting in an existing hi-rise office building.  All circuits are existing.  PLAN CHECK ONLY for ENERGY, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46831	18041-10000-41199	14600 W ARMINTA ST	91402	6	189B149   522	2210023003	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.21329	-118.45088	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46832	13041-10000-32478	7563 W BEVERLY BLVD	90036	5	138B177   410	5526041014	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.0763	-118.35479	FULL PLAN CHECK FOR A FIRST-TIME TENANT RESTAURANT. TOTAL AREA OF PROPOSED WORK IS FOR AN 856 SQ FT AREA. EMERGENCY LIGHTS TO BE INSTALLED. (E) existing 200a 120/240v 1ph, 3w service. note: see 11041-10000-26461 for more information, if applicable.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46833	18041-20000-42951	17554 W VENTURA BLVD	91316	5	171B129   419	2290008020	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Issued	11/15/2018 12:00:00 AM	ADDRESS	34.16159	-118.51593	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a conversion of a portion of existing autobody to office space. Total lighting area = 1,968 sq. ft.Note: Building permit has been issued under 18016-20000-07195	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46834	13041-10000-18722	12315 W LANDALE ST	91604	2	165B165    29	2364014039	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.15233	-118.40162	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A STANDARD PLAN. SYSTEM SIZE IS 10.29 KW. USING 42 MODULES IN 3 STRINGS. TRANSFORMERED INVERTER [INVERTER: FRONIUS # IG PLUS V 7.5 |||| MODULES: TRINA SOLAR # TSM-245PC05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46835	16041-20002-30884	3624 S 5TH AVE	90018	10	120B189  1373	5044030021	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.02208	-118.32226	Revisions to approved set.  Relocation of equipment.  Only sheets PV-0.0 and PV-3.0 are affected.  $0 plan check fee is due to State Senate Bill SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46836	17041-10000-12815	384 WORLD WAY MSC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	33.94339	-118.40887	PC, power and energy,  MSC Terminal with (4) medium voltage services. Total affected area is 647,538 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46837	19041-10000-45786	13010 N BRADLEY AVE	91342	7	222B145   109	2506011005	M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.30639	-118.46076	t-24 only. replace flourescent troffers with new led retrofit kits and remove hid fixtures and replace with new led fixtures. Total affected area is 45520 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46838	15041-20000-01584	8707 N SHIRLEY AVE	91324	12	195B117   178	2783025802	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.22881	-118.55807	PLANCHECK FOR POWER ONLY PER APPLICANTS REQUEST. INSTALLATION OF TWO NEW  400 AMP DISTRIBUTION BOARDS PDSC#1 AND PDSC#2 ONLY. LOAD ON THE BOARDS TO BE PART OF DIFFERENT PERMITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46839	18041-20000-39343	351 N MARTEL AVE	90036	5	138B181   173	5526038004	R1V2-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	08/24/2019 12:00:00 AM	ADDRESS	34.07769	-118.35123	Plan check for the addition of a Tesla PowerWall onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46840	17041-10000-04637	941 N HIGHLAND AVE	90038	4	144B185  1015	5532012041	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.08829	-118.33879	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN (E) MULTI MEDIA PRODUCTION SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 9263 SQ. FT. B#16016-10000-31168	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46841	11041-20000-25476	2316 S GENESEE AVE	90016	10	123B173    31	5064028013	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.03733	-118.36844	New 6.0 KW roof mounted PV system sor single family residence.  Applicant is using the standard plan for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46842	14041-10000-21393	14402 W CALIFA ST #4	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46843	12041-10000-03325	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check new optional stand-by backup generator system located on roof of parking structure for UCLA Data Center. System includes new ATS equipment, distribution boards, panel boards, xfrmer, and ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46844	12041-10000-10472	3150 W WILSHIRE BLVD	90010	10	132B197   112	5077010023	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	Plan check power and energy for new high rise building with 23-story 200-unit apartment (East Tower)  and  29-story 264-unit apartment (West Tower) over retail/restaurant and parking garage.  Site located in methane zone. Two 4000A servicse supplying building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46845	18041-10002-28128	4733 W SUNSET BLVD	90027	13	147B197   604	5543012018	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	Yes	1912.01	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.09833	-118.29305	PLAN CHECK FO CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE CONDUIT RE-ROUTING AND CHANGES TO MAIN METTER AND DISCONNECTS - DELTA CHANGES HAVE BEEN CLOUDED UNDER 4 AND B1 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46846	12041-10000-06138	116 N ROBERTSON BLVD #900	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM	03/19/2012 12:00:00 AM		Permit Finaled	06/01/2012 12:00:00 AM	ADDRESS	34.0758	-118.38356	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO 9TH FLOOR OFFICE SPACES CEDARS-SINAI. NO PATIENT CARE AREA. PERMIT FOR NEW BRANCH CIRCUITS AND WATERHEATER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46847	12041-10000-13139	20525 W MAYALL ST	91311	12	204B109   342	2741025005	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.25373	-118.58078	"PV installation for a single family dwelling. 9.2kW Rooftop system.  Plan check is only for Photovoltaic system.  Permit fees are under ""Inspection"", applicant has pulled a separate permit for New Service Upgrade."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46848	19041-20000-06886	515 S FIGUEROA ST 16th Floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI to 16th floor restrooms.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46849	10041-20000-10511	9649 W LAWLEN WAY	90210	5	144B161   412	4355019043	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	09/27/2010 12:00:00 AM	ADDRESS	34.09484	-118.41636	Plan check for new 600A service single-family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46850	17041-10002-20480	835 W JEFFERSON BLVD UNIT#H	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	PC for changes to water heater unit. All changes clouded under Delta 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46851	14041-20000-32547	13720 W SHERMAN WAY B	91405	2	183B157   987	2216027023	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.20099	-118.43222	PLANCHECK FOR T24 ENERGY ONLY.   TI TO CHANGE THE USE OF (E) RETAIL SPACE TO SMALL SIT DOWN SUBWAY RESTAURANT. 1000 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46852	12041-10000-25988	600 S HARVARD BLVD Suite A	90005	10	135B193   877	5503026007	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.06322	-118.30393	CONVERTING TWO EXISTING COFFEE SHOP (3744 W 6TH ST ) AND (600 S HARVARD BLVD) TO NEW KOREAN BBQ; RESTAURANT TI   3206 SF  SUITE A; NEW ADDED LOAD IS LESS THAN 300APLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46853	11041-10000-00301	3025 S FIGUEROA ST	90007	8	120A203    13	5123010004	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			01/07/2011 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	06/02/2011 12:00:00 AM	ADDRESS	34.0245	-118.27873	INSTALLATION OF EMERGENCY UNIT EQUIPMENT IN THE CORRIDORS OF THE 3 FLOORSNEW 3-STORIES   34 UNITS 9-TYPES APARTMENT BUILDING WITH ABOVE GRADE PARKINGSPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46854	12041-20000-10528	23701 W LADRILLO ST	91367	3	171B093   390	2047004008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.16527	-118.64197	7.755 PV system. Roof mounted. Single Family Dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46855	15041-20000-23703	15800 W STRATHERN ST Bldg. 3	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.21559	-118.47752	Plan check for power and energy.  Total area = 1,035 sq. ft. (indoor) + 400 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46856	13041-20000-09303	1680 N VINE ST STE 200	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for energy only. Conference rooms and offices of commercial high rise. Suite 200. Taft Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46857	18041-20000-13006	5855 N TOPANGA CANYON BLVD 3rd Floor	91367	3	174B101    12	2146006011	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Issued	04/11/2018 12:00:00 AM	ADDRESS	34.17697	-118.60536	3rd floor tenant improvement for commercial office.  Total square footage 9,985 sq ft.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46858	19041-10000-50413	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2021 12:00:00 AM		Permit Finaled	12/23/2022 12:00:00 AM	ADDRESS	34.19008	-118.60565	FULL PC FOR A NEW MOVIE THEATER, SCOPE OF WORK IS  TWO NEW DISTRIBUTION PANELS (800A AND 1200A) THAT FEED VARIOUS TRANSFORMERS, AND ALL ASSOCIATED DITRIBUTION EQUIPMENT AND ALL  ASSOCIATED SUBPANELS. NOTE THIS IS ELECTRICAL SYSTEM IS FEED BY TWO FEEDERS OFF TWO DISTRIBUITION PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46859	17041-10000-44885	13645 W VANOWEN ST	91405	2	183B157   964	2328013042	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Issued	03/19/2018 12:00:00 AM	ADDRESS	34.19408	-118.43051	Plan check for Title 24 only in existing space fire damaged. Total area: 5278 sq ft. Note: Building Application number: 17016-10000-35419	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46860	15041-10000-14596	340 S MAIN ST BLDG  B-DISH RM	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM			PC Approved	05/13/2015 12:00:00 AM	ADDRESS	33.99519	-118.47673	REMODELING THE DISH ROOM OF THE CAFE INSIDE AN OFFICE BUILDINF: NEW LUMINIRES ;DISH CAROUSEL; CKTSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46861	12041-10000-07813	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	Wiring and equipment installation for end-use equipment to serve TBIT Gate nos. 131 and 133 consist of(4) PBB, (2) FGP, (2) AHU, and (2) PWC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46862	17041-20001-01429	8915 N WOODLEY AVE	91343	12	195B141   264	2688004017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.2325	-118.48529	expedite per applicant.pv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46863	19041-10000-27476	1151 W PACIFIC COAST HWY #4B	90710	15	036B197  1058	7413003***	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Issued	08/13/2019 12:00:00 AM	ADDRESS	33.79027	-118.29705	ENERGY PLAN CHECK ONLY FOR INTERIOR TENANT IMPROVEMEMNT FOR (E) PIZZA RESTAURANT. AREA OF SCOPE 1,111SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46864	12041-20000-17613	10250 W SANTA MONICA BLVD #6	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. of existing retail space #6.  Install general/emergency lighting.  Plan check for energy only. Permit Fees are under Inspection.  All circuits are existing per contractor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46865	17041-20000-44006	3921 N LAUREL CANYON BLVD	91604	2	162B165   437	2369013019	R1-1-RFA-RIO, R1-1VL-RFA-RIO, [Q]RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.14179	-118.39477	New corridor lighting and power for 2-level addition to (E) 2-story school.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46866	15041-20000-11720	6250 N TOPANGA CANYON BLVD 1595-C	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	TI to new commercial building. First time tenant. Plan check for power and energy. Total Sqft. 2,171	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46867	17041-20000-06001	2525 W WILSHIRE BLVD	90057	1	133-5A201  95	5141006017	C4-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Apartment			02/24/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	04/05/2021 12:00:00 AM	ADDRESS	34.06059	-118.28114	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP, 2 RPS,  570 DEVICES.   new 7-story mixed-use building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46868	14041-10002-22168	1501 N MAIN ST	90012		136-5A217 147	5409003042							Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	11/17/2014 12:00:00 AM	PIN	34.06690042	-118.22937525	Installation of new PV system and associated power conditioning equipment.  System size = 449.8 kWdc, 360 kWac.  18 inverters (20 kW each), 1384 modules (325 W each)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46869	12041-10000-31179	17015 W DEVONSHIRE ST	91325	12	204B133   170	2695020033	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.25768	-118.50301	CHANGE FROM MEDICAL BUILDING TO CHURCH/SCHOOL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46870	10041-20000-17486	1410 S ABBOT KINNEY BLVD	90291	11	108B145  1421	4238004052	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM			PC Approved	09/03/2010 12:00:00 AM	ADDRESS	33.99043	-118.46567	energy plan check retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46871	12041-10000-00378	2049 S CENTURY PARK EAST # 1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM			PC Approved	01/06/2012 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR OFFICE TI #1940	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46872	15041-20001-04414	3848-3852 S CRENSHAW BLVD suite 201	90008	10	117B185   775	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM			Corrections Issued 2	12/04/2015 12:00:00 AM	ADDRESS	34.01604	-118.33474	Change to approved set of plans. Changes include addition of controls and light fixtrues. Changes apply to delta 1 only. {{{{{{TI TO AN EXISTING TWO STORY COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD =400AMPS.  PLAN CHECK FOR ENERGY AMD EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE PERFORMED IN THE SECOND FLOOR.  TOTAL SQUARE FOOTSGE 7389.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46873	17041-10000-22718	2920 S OVERLAND AVE	90064	5	123B161   488	4255009901	OS-1XL	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.03349	-118.41816	PC FOR FA.REPLACING FA PANEL.  ALL ELSE IN EXISITING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46874	13041-10000-33160	2800 N PHELPS AVE	90032	14	139-5A233  11	5217005012	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	Apartment			11/26/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.07845	-118.17706	Plan check for energy and power for a new building on 3 levels of under ground  garage and 5 levels of 237 apartments.NOTE: DISCARD APPLICATION DUE TO INCORRECT ADDRESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46875	12041-10000-30800	15541 W ROSCOE BLVD	91343	6	192B145   364	2654028009	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.22156	-118.47147	PV2 SOLAR INSTALLTION ROOF MOUNT AND CAR PORT SINGLE STORY BUILDING[INVERTER TYPE: POWER ONE PVI-10.0-I-OUTD-S2-US-480][MODULE: REC250PE BLK] 16 STRINGS, 187 MODULES SYSTEM SIZE 46.75 KWDCADDRESS CHANGE TO 15505 PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46876	17041-10000-18902	6631 N FIGUEROA ST	90042	14	156A231   122	5486009036	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	Yes	1832.21	Electrical	Electrical	Apartment			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.12297	-118.18524	Remove and replace FACP in existing apartment building.  Install one new smoke detector and graphic annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46877	16041-10000-24959	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM			PC Approved	07/15/2016 12:00:00 AM	ADDRESS	34.21302	-118.45859	Energy plan check for (1) room modification located in a commercial building (Target).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46878	11041-20000-11525	11600 W WILSHIRE BLVD 3rd FLOOR	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM	06/06/2011 12:00:00 AM		Permit Finaled	06/24/2011 12:00:00 AM	ADDRESS	34.05034	-118.45947	PLAN CHECK 24 ENERGY GENERAL/EMERGENCY LIGHTING FOR RESTROOM AND CORRIDOR ON 3RD FLOOR. PERMIT FOR REPLACING LIGHTING FIXTURES AND LIGHTING WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46879	18041-20000-07339	13445 N GLENOAKS BLVD	91342	7	225B145    79	2501021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Issued	04/18/2018 12:00:00 AM	ADDRESS	34.31638	-118.4614	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of a new optional standby generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46880	19041-20000-02327	10259 N TUJUNGA CANYON BLVD 1-28	91042	7	204B197   976	2558022059	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Apartment			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.25382	-118.29122	New FACP and smoke detector for (E) fire alarm system.  Connect all (E) devices to new FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46881	17041-20001-35812	24022 W SCHOENBORN ST	91304	12	192B089   149	2017037017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	34.22111	-118.64972	expeditepv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46882	14041-20000-01615	1947 N CAHUENGA BLVD SUITE 104	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.10686	-118.33085	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON SUITE 104	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46883	13041-20000-09814	1985 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.06159	-118.20463	Change to lighting and receptacles in an existing Lecture Hall Rooms 108 & 112 at Stauffer Pharmaceutical Science Building.  Occupancy load is greater than 99, Place of Assembly.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46884	16041-20000-21840	6922 W HOLLYWOOD BLVD FLR 6-7	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	TI TO AN EXISTING COMMERCIAL BUILDING HIGH RISE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  SCOPE IN 6TH AND 7TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46885	15041-10000-05298	8120 N WEBB AVE	91605	6	189B169    27	2310007021	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.21832	-118.38983	Energy plan check for a commercial warehouse building, replacing HID fixture with new LED fixture; total area is 11056 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46886	17041-10000-44881	1256 W 7TH ST 3rd FL	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.05216	-118.26774	ALTERATIONS IN THE CORRIDOR AND RESTROOMSPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46887	18041-10000-47837	7782 N SAN FERNANDO ROAD	91352	2	189B177   432	2405001005	[Q]CM-1, [T][Q]MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.21264	-118.35851	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46888	13041-10000-10102	1815 S SOTO ST 1st FLOOR-2nd FLOOR	90023	14	117A219    92	5169029017	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.01602	-118.22017	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING 4 STORY OFFICE BUILDING (SCOPE OF WORK ON 1ST-2ND FLOOR). 16627 SQRFT. ADDING NEW ELEVATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46889	14041-20000-04366	301 E FLORENCE AVE	90003	9	102B205   798	6011008030	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Info Complete	07/18/2014 12:00:00 AM	ADDRESS	33.97488	-118.269	"Site lighting for a new core and shell retail building (7 Eleven).  New 600A service, panels, branch circuits, and outdoor lighting.   Plan check for power and energy. ""COMPLY WITH DEPARTMENT ORDER effective date09/08/2004. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46890	14041-10001-07458	3150 W WILSHIRE BLVD STE #116	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	Modifications to approved set.  Change of lighting fixtures and additional receptacle outlets.  (((PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT, Fatburger. HIGHRISE.  COMMERCIAL   Bldg # 13016 10 26249) - INT T.I. OFRESTAURANT SHELL SPACE -  SF. PROPOSED UNROOFED OUTDOOR EATING AREA - 22 SEATS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46891	14041-20001-16555	9110 S CENTRAL AVE	90002	9	094-5A209 133	6043008900	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM			PC Approved	12/09/2014 12:00:00 AM	ADDRESS	33.95357	-118.25622	12.9.2014 - Plan check for modifications to approved set. Adding a new room 114 to the school (addl. area of 940sqft), update power and lighting plans to reflect new circuitry and Title-24 compliance. Also adding new outdoor lighting (addl. 13,886sqft), plan check outdoor lighting for Title-24 compliance.[TI for upgrading a new electrical service system with 600amp. Fire alarm variance has been filed.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46892	15041-20000-16491	2567 S ARMACOST AVE	90064	11	120B149   368	4257001041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.02584	-118.44637	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46893	16041-10000-45280	450 S WESTERN AVE #220 & 221	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	34.06562	-118.30887	Full plan check TI, first time tenant to beauty shop/salon on second floor of plaza. Adding new electrical equipment and lighting. Area: 8210. Existing MS loads were calculated from existing approved set of plan (100041-20000-21035).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46894	12041-10000-17498	8471 W BEVERLY BLVD	90048	5	138B173   428	5514012025	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM			PC Approved	07/26/2012 12:00:00 AM	ADDRESS	34.07621	-118.37572	Plan check T24 Energy/Emergency lighting for remodel of existing retail space #208 (Weight Watchers)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46895	16041-10000-14822	18528 W CHASE ST Build. A-Build. B	91324	12	192B125   315	2785018029	R3-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Apartment			04/27/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.22434	-118.53707	NEW FIRE ALARM SYSTEM ON 17 UNIT APARTMENT.   (1) F.A. PANEL    (2) COMM. PANEL      (112) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46896	17041-20000-20130	4930 N GAVIOTA AVE	91436	5	168B141   207	2261020046	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.15925	-118.4808	Plan check for AC coupled battery backup system.(1) 5kW Tesla Powerwall 2.Existing solar system on roof.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46897	16041-10000-34793	357 E 92ND ST	90003	9	094-5A205 221	6041028019	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	33.95303	-118.2675	Plan check for PV roof mounted system. System size: 3.8 kW with 18 modules and 1 inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46898	16041-20000-08545	18155-18157 W PARTHENIA ST	91325	12	195B125   800	2769019036	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	PIN	34.22908883	-118.52906755	Plan check for energy only. New lighting (incl. emergency) for additions to existing restaurant and existing repair garage (new manager's office). Indoor/outdoor lighting. Indoor - 498sqft; outdoor - 1,416sqft. Total 1,914sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46899	13041-10000-15296	2324 N JUPITER DR	90046	4	150B177    41	5569013057	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.11095	-118.36366	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 17.25 KW.  69 MODULES, 3 INVERTERS AND TWO COMBINER BOXES. [MODULES: TRINA SOLAR # TSM-250PA05.08 |||| INVERTERS: POWER-ONE # POWER-ONE-PVI-6000-OUTD-US AND POWER-ONE # POWER-ONE-PVI-5000-OUTD-US AND POWER-ONE # POWER-ONE-PVI-3.6-OUTD-US]. upgraded main service panel to 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46900	15041-20000-11174	13230 W CROWLEY ST	91331	6	195B157   905	2627024006	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.22897	-118.4208	PV1. Standard plan. Install roof mounted PV system sized 3.2 kW. Interconnected with main service panel.(15) Enphase M215 Microinverters(15) SW 280 Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46901	16041-10001-09173	501 W EL SEGUNDO BLVD	90248	15	081B201   259	6132002024	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	33.91659	-118.28337	PC ONLY FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 4 ON PLANS. REVISED SINGLE LINE LAYOUT AND BUS RATINGS OF PANELBOARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46902	14041-10000-20385	9255 N SUNLAND BLVD	91352	6	198B173    88	2408002023	M1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			Reviewed by Supervisor	08/06/2014 12:00:00 AM	ADDRESS	34.23755	-118.36793	HAZARDOUS AREA. 2500 GALLON DISEAL TANK ABOVE GROUND.ONE PUMP AND 1 DISPENCER. COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46903	13041-10000-14667	3185 E WASHINGTON BLVD	90023	14	117A223    39	5169020003	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.01526	-118.21058	PV2 Plan check for new 41.8KW roof mounted photovoltaic system warehouse building usinf two transformerless inverters. Existing 480V/277 3ph system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46904	18041-20000-14606	11676 W TUXFORD ST	91352	6	192B169   420	2632023048	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.22289	-118.38698	Plan check for power and energy for new wearhouse and manufacturing building 1 story, core and shell for different tenant in the spaces. Total area: 27,155 sq ftB#18010-20000-00414	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46905	19041-20000-10361	1442 S SHENANDOAH ST	90035	5	129B169   177	4303011011	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			03/22/2019 12:00:00 AM			Reviewed by Supervisor	04/04/2019 12:00:00 AM	ADDRESS	34.05309	-118.38161	Plan check for new four story 8 units multi-family with 8 typical units. 800A Service. Total area: 10,701 sq ft. B#18010-100000-03234	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46906	16041-20000-33365	14835-14837 W BESSEMER ST	91411	6	177A149   177	2241024018	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	PIN	34.18104068	-118.45656703	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 800 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46907	15041-10000-16738	1831 S SAWTELLE BLVD 1-30	90025	11	126B149   385	4261021024	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			06/01/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.04294	-118.4457	(N) 4-story 30-unit apartment with 3 stories over subterranean and grade-level parking.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46908	12041-10000-04312	849 E NEW DOCK ST Berths-212-216	90731	15	024B209    15	7440021914		Harbor				9800.31	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	33.75812	-118.24877	NEW 34.5KV SWGR TO SUPPLY 6.6KV SWGR EACH AT BERTH 212 AND AT BERTH 216; THIS IS PHASE 2 OF THE AMP DISTRIBUTION AT EACH OF THE MENTIONED BERTHS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46909	16041-10000-11034	4418 VINELAND AVE	91602	4	165B173   268	2423008001	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Issued	04/07/2016 12:00:00 AM	PIN	34.15104824	-118.36988917	TI to an (E) office build. Scope include (partial) 1st and 2nd fl. corridor and restrooms. Install new light fixtures. PC for T-24 only. Total area: 2,397 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46910	19041-20000-16340	4933 N TEXHOMA AVE	91316	5	168B129   102	2290009011	RE9-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.16013	-118.51666	Install 27 kWh energy storage system and associated distribution.  200A service panel upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46911	16041-30000-29121	2049 S CENTURY PARK EAST 14th FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing space High-rise building men and women restroom 14th Floor. Total lighting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46912	16041-20000-19542	1524 W 96TH ST	90047	8	093A195   206	6055017046	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	33.94854	-118.30338	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.5KW. STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46913	14041-20001-03369	12344 N EDGECLIFF AVE	91342	7	219B145   637	2611037033	RA-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.2945	-118.46346	Expedite Fee ONLY****Roof mounted PV system with 6KWdc.****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46914	15041-20000-28475	7175 W WILLOUGHBY AVE	90046	5	144B181   752	5531016007	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.0872	-118.34594	Plan check Title 24 only for existing office space. Total indoor area: 7,014 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46915	18041-10000-03066	1655 W MANCHESTER AVE	90047	8	097-5A195 286	6034030041	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.96015	-118.30647	REMOVE OUTDOOR METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46916	15041-10000-43923	9301 N TAMPA AVE #112	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC for energy only to a commercial retail building. Tenant improvement adding new lighting and controls to existing panel.  Total Sqft = 2047	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46917	16041-10001-45246	10250 W SANTA MONICA BLVD # 2840	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM			PC Approved	02/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set noted under Delta-5:  added inverter, removed all bug-eyes, T-24 is not affected. Permit is covered under master# 16041-10000-45246	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46918	18041-10001-03105	5101 S EDSEL AVE	90066	11	105B161   409	4221011059	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	33.98559	-118.4163	PEXPEDITE PER APPLICANT REQUEST...	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46919	18041-20003-12992	16929 W DEVONSHIRE ST	91344	12	204B133   147	2684012044	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Approved	08/31/2018 12:00:00 AM	ADDRESS	34.25767	-118.50122	08-31-2018 Changes to an approved set of plans. Changes include update panel schedule calculation and main circuit breaker size. All changes has been clouded as delta 2.  Plan check only, permit covered under Master Application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46920	16041-10000-07974	128 S PACIFIC AVE	90731	15	018B197  1259	7449024028	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	33.74281	-118.28772	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (STORAGE/WAREHOUSE/ OFFICE/RETAIL SPACE). SCOPE INCLUDES NEW LIGHTS IN THE WAREHOUSE/STORAGE/RETAIL SPACES. TOTAL AFFECTED AREA IS 5616 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46921	17041-20000-14307	1164 S DACOTAH ST	90023	14	120A223    88	5190010900	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Issued	05/22/2017 12:00:00 AM	ADDRESS	34.02419	-118.21008	Plan check for the installation of (2) temporary generators for existing pumps at a Public Works pumping plant. Temp generators will be used while the previously permitted back-up generator and ATS are being installed.  Scope of permit for a (1) day temporary installation.Note: Permit for the permanent back-up generator and ATS has been pulled under 15041-10000-24892	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46922	18041-30001-40575	13445 N GLENOAKS BLVD	91342	7	225B145    79	2501021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.31638	-118.4614	Changes to an approved set of plans, Note changes on clouded areas only. Scope of work includes change of fire alarm panel and addition of 7 FA devices. Install new Fire alarm system, (1) FACP, (73) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46923	17041-20001-42740	5812 E TIPTON WAY	90042	14	159A229   259	5480011010	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.12947	-118.19178	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 3 kWac and consists of (14) modules, (1) inverter, (1) load center, and (1) battery unit. MSP is center-fed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46924	11041-20001-09851	7248 N FULTON AVE	91605	2	186B157   583	2327002015	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM			PC Approved	05/24/2011 12:00:00 AM	ADDRESS	34.2026	-118.42239	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR CHG OF USE FROM MANUFACTURING  TO MUSIC STUDIO. REVISION TO APPROVED PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46925	15041-20000-10342	17087 W PARTHENIA ST	91325	12	195B133   427	2690010009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Expired	05/02/2017 12:00:00 AM	ADDRESS	34.22866	-118.50553	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (32) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46926	19041-10000-44162	9150 S LOYOLA BLVD Prac Range-Parking	90045	11	093B161     3	4119006913	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	11/04/2021 12:00:00 AM	ADDRESS	33.95408	-118.41705	Full PC for power and energy.  Scope includes a new 1200A distribution board, new 600A distribution board, transformers, new panels, new circuits, and new lighting. Electrical equipment is being from a 5000A service. Total affected area is 630,069 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46927	14041-10000-03702	5161 N LANKERSHIM BLVD STE #280	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.16452	-118.37469	T24 PART 6 ENERGY FOR (E) OFFICE SPACE, LOW-RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46928	17041-10000-13061	5540 W CENTURY BLVD	90045	11	090B173   130	4129029015	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	33.94512	-118.37722	PC for energy only, Outdoor Title-24.  Removing HID fixtures and replacing with New LED. area: 41,500	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
46929	13041-10000-16925	520 S OLIVE ST	90013	14	129A211    32	5149031900	OS-1XL	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.0488	-118.25326	Installation of fan coils and replacement of existing light with fluorescent lighting in the back rooms of a theater.  Newly connected load < 400 A, title 24 plan check only.   Interior 986 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46930	18041-20000-07340	4727 N ARCOLA AVE	91602	4	168B177   616	2420025009	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.15649	-118.35511	PLAN CHECK FOR A BATTERY BACKUP SYSTEM ON EXISTING PV SYSTEM - SYSTEM CONSIST OF NEW TESLA POWERWALL (14KWH) AND EXISTING 6.48KVA SOLAR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46931	16041-20001-19815	4225 N ETHEL AVE 1-32	91604	2	165B161   875	2375016030	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			Reviewed by Supervisor	06/14/2016 12:00:00 AM	ADDRESS	34.14679	-118.41845	PV2.  Install 7.7 kW roof mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46932	16041-10000-29668	837 N NORTH SPRING ST #104	90012	1	135A215   307	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.06303	-118.23651	INTERIOR TI TO SECOND FLOOR AND PART OF FIRST FOR OFFICEES. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46933	16041-20000-04394	535 S GLENROCK AVE	90024	5	135B149   304	4363010022	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.04	Electrical	Electrical	Apartment			02/08/2016 12:00:00 AM			Reviewed by Supervisor	03/30/2016 12:00:00 AM	ADDRESS	34.06718	-118.45129	Plan check for power only. Project site is an existing 4-unit apartment building. Project scope is a service upgrade to 600-amps and new loads on the tenant panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46934	10041-10000-17689	10250 W CONSTELLATION BLVD 26Th Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI IN AN EXISTING OFFICE AREA IN SUITE #2600. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46935	15041-10000-30516	12694 W MILLENNIUM	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	33.97644	-118.41485	PV1 3kW AC (AC MODULE) roof-mounted system with (12) modules and one load center interconnecting through the main service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46936	16041-20000-24902	8852 N AMESTOY AVE	91325	12	195B133   223	2690012001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.23187	-118.50682	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.160 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46937	10041-20000-16943	3616 S TROUSDALE PKWY #B55	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM	10/08/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	ADDRESS	34.01983	-118.28534	Plan check T-24 Energy (general/emergency) lighting renovation in the basement of USC AHJ Spatial Sciences Rm #B55.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46938	13041-10000-20901	6005 N VINELAND AVE	91606	2	177B173  1150	2337001046	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.17962	-118.3705	TITLE 24 PLAN CHECK ONLY FOR ;2-STORY ROOFTOP WIRELESS FACILITY.  200 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46939	14041-10000-13241	1928 N MANDEVILLE CANYON ROAD	90049	11	135B137     5	4426010022	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Expired	10/03/2016 12:00:00 AM	ADDRESS	34.06969	-118.49514	PLAN CHECK FOR POWER FOR REMODEL OF HOUSE - Main structure is being remodeled and an addition is being added to the main structure. Provisions (conduit stubs) for future site buildings. SOME NEW CIRCUITS AND PANELS DISTRIBUTION EQUIPMENT IS RATED AT 800AMPS. Changes on plan include increase of feeder to M2 to 250kcmil and luminaire information.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46940	18041-20000-10330	4038 N WILLOW CREST AVE	91604	2	162B177   201	2423035006	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.14266	-118.36271	PV1.  Install 4.95 kW DC roof mounted grid tied PV system.  (15) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46941	14041-10000-21990	1326 W 12TH ST	90732	1	015B193  1087	7459016004	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Expired	11/16/2016 12:00:00 AM	ADDRESS	33.73349	-118.30614	PV1, INSTALL 2.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(8) MODULES: KYOCERA KD 255GX(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46942	17041-10000-24568	10049 S LILAC ST 101-301	90002	15	091-5A217 109	6046019921	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	33.94629	-118.2304	POWER PLAN CHECK FOR  3-STORY, 6-UNIT APARTMENT BUILDING; SCOPE INCLDUING A 400A SERVICE AND (7) PANELS. NOTE, THIS BUILDING IS ONE OF THE (16) BUILDING ON THE SAME SITE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46943	15041-20000-43223	4933 N WORTSER AVE	91423	4	168B161    81	2358025003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.16042	-118.41725	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (32)MODULES-KYOCERA #KU2656ZPA(1)INVERTER- ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46944	18041-30000-48834	4830 S LINCOLN BLVD	90094	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Issued	12/27/2018 12:00:00 AM	ADDRESS	33.97827	-118.4358	Plan check for Title 24 only. Project site is an existing commercial retail space. Project scope is a tenant improvement. Total lighting area = 965 sq. ft.Note: Building permit has been issued under 18016-30000-28584.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46945	18041-10001-04518	12918 W RUBENS AVE	90066	11	105B157   485	4223007023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM			PC Approved	12/31/2018 12:00:00 AM	ADDRESS	33.98447	-118.42877	12/31/18CHANGES TO AN APPROVED SET OF PLANS, SCOPE OF WORK INCLUDES THE ADDITION OF DISCONNECTS. ___________________Plan check for battery back up power wall to existing PV roof mounted system. Total battery back up size: 13.5kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46946	11041-10000-06707	525 E ANAHEIM ST 525-625	90744	15	030B209     7	7423023004	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	09/06/2011 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	33.78047	-118.25663	INSTALLING TRANSFORMER, AND SWITCHBOARD.  ALSO INSTALLING MCC'S ALONG WITH OTHER EQUIPMENT.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46947	19041-10000-05469	2021 W COLORADO BLVD	90041	14	162A223    86	5671009900	PF-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.13941	-118.21086	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46948	16041-10000-04873	400 WORLD WAY T4-RAMP	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	33.94221	-118.40701	T-24, TI TO 7 RESTROOMS IN LAX. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1342.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46949	18041-20002-44319	3717 N LONGRIDGE AVE	91423	4	162B161   646	2385008001	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.13829	-118.41838	PV1.  Install 23.04 kW DC grid tied roof mounted PV system.  (64) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46950	14041-10001-25727	4706 W OAKWOOD AVE	90004	4	138B193   298	5522032012	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	ADDRESS	34.07713	-118.30958	3/14/16: Change to approved set. Field correction on Delta-2:(1) Shorther feeder length to PNL 105, 204, 205, 304, 305, 404, 405, 406(2) Revised conductor size from #3 to #4 for all feeder to PNL 105, 204, 205, 304, 305, 404, 405, 406(3) Revised the size of sump pump to bigger Hp; therefore increase the size of ckt breaker.No New equipment. Permit under 14041-10000-25727 <<new 5-stories 27units apartment building>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46951	10041-20000-07804	3410 W 3RD ST	90020	4	135B197   307	5501024028	(Q)P-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	34.06884	-118.29027	NEW LIGHTING THROUGHOUT SALES AREA, NEW POWER FOR NEW FIXTURES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46952	18041-30000-26574	6922 W HOLLYWOOD BLVD 12TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLAN CHECK FOR T24 ONLY, RESTROOM RENOVATION ON THE 12TH FLOOR. APPROX 303 SF TOTAL. PROVIDING NEW LIGHTING AND RECEPTACLES, CIRCUITS ARE FED FROM EXISTING PANELS.(B# 18016-10000-08242)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46953	10041-20000-10427	110 E 9TH ST #A979	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.04107	-118.25479	Plan check for TI (general/emergency) lighting for office spaces on the 9th floor of high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46954	13041-20000-35922	206 N KENTER AVE	90049	11	132B141    66	4403011007	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.06124	-118.48025	PV1 TRANSFORMERLESS SYSTEM. USING SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 6.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46955	13041-10001-33753	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	EPC for T24 for Tom Bradley LAX project. Install a new 300KVA Xformer & a new 1200 Amp panel & Conduit stubs for (5) future tenant. No new load is added except 4 new lighting circuits. All FUTURE electrical installations require complete electrical plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46956	15041-10000-16156	7435 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.20582	-118.48615	(2) NEW AIRPLANE HANGARS WITH AN ATTACHED 2-STORY OFFICE. NEW COMMERCIAL BUILDING TO THE VAN NUYS AIRPORT. FULL PC, PC FOR POWER AND ENERGY ONLY. 1600 SERVICE AND TOTAL SQ. FT. 67377. FEES PER APPLICANT, PRE MADE CHECK. NO TI-24FEES,  FEES NEED TO BE ADJUSTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46957	14041-20000-13141	8828 W KEY ST	90035	5	129B169   742	4305020009	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.04981	-118.38579	PV1.  Install 5.43 kW roof-mounted utility-interactive PV system.  Enphase microinverters.  (24) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46958	16041-10000-15804	1022 S STANLEY AVE	90019	4	132B177   838	5085002023	R2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.05679	-118.35824	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(14)MODULES-KYOCERA #KD255GX-LFB3(1)INVERTER-PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46959	14041-10000-26251	5201 N VAN NUYS BLVD	91403	4	172-5A151 218	2249006020	(T)(Q)C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1288.02	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	PIN	34.16536974	-118.44966386	PLANCHECK FOR A NEW 3,058 S.F. CAR WASH & TEMPORARY AUTO SERVICE BLDG PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46960	13041-10000-12061	1168 S BARRINGTON AVE	90049	11	129B145  1183	4265001039	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	07/29/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.0499	-118.46096	ti, NEW FIRST TIME RESTAURANT, PC FOR T24 AND POWER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46961	13041-10000-06061	20832 W VALERIO ST #3	91306	3	186B109  1048	2113013***	(Q)RD2-1, (Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.20456	-118.58754	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. 17 MODULES AND 1 CENTRAL INVERTER. TOTAL SYSTEM SIZE: 4.165 KW. [INVERTER: POWER ONE PVI-3.8-I-OUTD-US] [SOLAR MODULE: TRINASOLAR TSM-245 PC/PA05}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46962	15041-20000-34219	13087 W RANGOON ST	91331	6	195B161   137	2628008012	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.23459	-118.4178	PV1, roof mtd. solar system 5.5 kW transformerless . (22) modules: Solarworld SW250 Poly, (1) inverter: Fronius Primo 5.0-1	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46963	17041-10000-13944	630 W 85TH ST	90044	8	097-5A201 197	6032015029	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	33.96098	-118.28501	PV INSTALLATION OF 2.56 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOME. 8 AC MODULESNOTE: Permit is paid under PCIS#17041-90000-11892	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46964	15041-10000-04290	9146 N OWENSMOUTH AVE	91311	12	198B105   165	2746011008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.2365	-118.60175	Plan check for Title 24 only. Project site is an existing building. Total lighting area = 6592 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46965	17041-10000-32552	17080 W SUNSET BLVD	90272	11	126B117   222	4415017007	RE40-1, [Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.0428	-118.5519	Remove HID fixtures and replace with new LED fixture  - Title 24 only. Total affected area 24200sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46966	16041-10001-11468	982 S CATALINA ST	90006	10	129B197    90	5078007019	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			PC Approved	06/05/2019 12:00:00 AM	ADDRESS	34.05324	-118.29462	Change to approved set by adding 3-ckts on the floor plan. All changes under delta-3 only(((Full PC for a newly constructed 13 unit apartment. Building is 6 stories plus a 2 level parking basement. New 1200 Amp service 120/240 3 phase 4 wire. 4 typical units (a,b,c,d) plus one unit in 6th floor). Total sq ft = 26,870.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46967	13041-20000-27577	23741 W KILLION ST	91367	3	174B089   597	2047010002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.16999	-118.64505	Modification to previously approved set of drawings.  Change only to location of panels on the roof.          <<<PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 11.13 KW. 42 MODULES AND 2 INVERTERS.>>>	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
46968	19041-10000-26048	1244 W INNES AVE	90026	1	138A211   275	5406015041	[Q]R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1977.00	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	08/14/2020 12:00:00 AM		Permit Finaled	04/24/2024 12:00:00 AM	ADDRESS	34.07126	-118.24986	FUL PC FOR A NEW 600A (3P, 4W) SERVICE, THAT FEEDS A 400A BUS THAT FEDS FIVE SUBPANELS. THE 600A SERVICE ALSO FEEDS A 200A BUS THAT FEEDS VARIOUS HOUSE LOADS. TOTAL AFFECTED AEA IS 5437 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46969	09041-10001-21847	7919 W SUNSET BLVD	90046	4	147B177   994	5551018008	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM			PC Approved	02/11/2010 12:00:00 AM	ADDRESS	34.09821	-118.36239	2-11-10 - Supplemental is for lighting changes.  All changes are clouded.  P/C is for Energy only :: TENANT IMPROVEMENT OF AN EXISTING  RESTAURANT.   NO  CHANGE OF USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46970	16041-20000-28990	21550 W OXNARD ST Suite 570	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,134 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46971	17041-20000-18891	649 S WALL ST	90014	14	127-5A211 227	5148023018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	12/29/2020 12:00:00 AM	ADDRESS	34.04256	-118.24822	Plan check for power and energy. Project site is a new 7-story building: 5 levels of residential and medical office over 2 levels of podium medical office and parking. Project scope is a core and shell. Total lighting area = 12,641 sq. ft.Note: Building application has been generated under 16010-10000-03925	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46972	18041-20000-04936	7805 N BELLAIRE AVE	91605	2	189B161   852	2305038030	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.21228	-118.41121	pv1install roof mounted pv system sized 8kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46973	16041-10000-09643	17383 W SUNSET BLVD 2ND FL-BLDG A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, LOBBY/COMMON AREA REMODEL IN AN OFFICE BUILDING 2ND FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1845.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46974	15041-10000-41787	909 S SANTA FE AVE	90021	14	123A217   108	5166012010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Issued	01/20/2016 12:00:00 AM	ADDRESS	34.03228	-118.23021	PC FOR POWER ONLY. UPGRADING SERVICEE AND NEW SWITCH GEAR FROM 600 A TO 800A. AND 2 400 METER FOR A COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46975	14041-20001-11618	1125 N LE GRAY AVE	90042	14	156A229   181	5485020018	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.12262	-118.19232	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. [[[[M250]]]  SYSTEM SIZE: 7.2KW(24) LG 300 MODULES(24) ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46976	11041-10000-26793	2670 N GRIFFIN AVE	90031	1	139-5A223  15	5206010039	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			PC Info Complete	04/05/2012 12:00:00 AM	ADDRESS	34.07841	-118.21167	Tenant improvement on 3 story commercial bldg, new  fire alarm. 124 devices and two panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46977	14041-20001-15596	10403 W VALLEY SPRING LANE	91602	4	165B177   796	2424015018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.14687	-118.35734	((EXPEDITE FEES)))PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 14.8KW AC USING 4 CENTRAL TRANSFORMERLESS INVERTERS. NONSTAND PLAN. NEW 400A PANEL. EXISTING 200A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46978	12041-20000-22809	12101 W BLUFF CREEK DR	90094	11	105B165   936	4211010103	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	33.97916	-118.40417	Tenant Improvement for a first time tenant.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46979	16041-20000-00608	5670 W WILSHIRE BLVD 204A	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Closed	01/23/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for addition fire alarm devices to existing fire alarm system. Total devices: 4 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46980	13041-10000-14792	3243 S MALCOLM AVE	90034	5	120B161   175	4254014030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.02822	-118.41766	PV1 5KW XFRMLESS. 2 STORY. NONSTD. ROOFMOUNT. (1) powerone PVI-4.2-OUTD-US.  [ 20 MOD: TRINA TSM-250PC05.08}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46981	14041-20001-32079	8741 W APPERSON ST	91040	7	204B189   620	2546003018	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.25584	-118.32359	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.5 KW. MICROINVERTER NON STANDARD PLAN. (22) ENPHASE MICRO INVERTER(22) CANDIAN SOLAR 250W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46982	15041-10000-06521	6316 N TOPANGA CANYON BLVD BLDG B	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	09/06/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	NEW FIRE ALARM SYSTEM IN BUILDING B ON WESTFIELD PLAZA. 147 DEVICES AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46983	16041-10001-14568	1616 W 209TH ST # 1	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	CHANGES TO APPROVED SET OF PLANS. CHANGE INCLUDES USE OF 8 MODULES AND CHANGE INVERTER TO SOLAREDGE SYSTEM WITH POWER OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46984	15041-20000-10703	201 N FIGUEROA ST	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.05859	-118.25142	Title 24 plan check only.  Total area = 720 sq. ft.T.I. to existing office building.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46985	14041-20000-31953	7900 N BALBOA BLVD	91406	6	189B133   403	2205006902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.21347	-118.50092	PROVIDE ELECTRICAL POWER FORM MAIN PANEL TO NEW SUBPANELS AT 7 DIFFFERENT HANGERS (TANGO, SIERRA, ROMEO, QUEBEC, PAPA, KILO, OSCAR). PLAN CHECK FOR POWER ONLY. PANEL SCHEDULE FOR HANGERS TO BE PROVIDED 11/24/2014 BY APPLICANT. PLAN CHECK FEES ESTIMATED FEES TO BE VERIFIED BY PLAN CHECKER. APPROVED POWER PLAN PROVIDED WITH SUBMITAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46986	17041-20000-18170	6500 W WILSHIRE BLVD 9th Floor	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.06371	-118.3703	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46987	16041-10000-22297	5999 W CENTER DR 4TH FLOOR	90045	11	102B169   959	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	33.9761	-118.38876	NEW ELEVATOR  LOBBY LIGHTING. PC FO T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46988	13041-10000-01737	785 N VIGNES ST	90012	14	132A217   391	5409025***	ADP, [Q]M3-1	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM			PC Info Complete	03/27/2013 12:00:00 AM	ADDRESS	34.05606	-118.23248	PLAN CHECK FOR POWER. NEW ADDITIONAL 1000KW EMERGENCY GENERATOR, UPGRADE EXISTING EMERGENCY GENERATOR, ELECTRICAL CONNECTION ROOF TOP EQUIPMENT FOR EXISTING LACMTA UNION STATION HIGH RISE BUILDING. 455' bus duct	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46989	13041-10000-35573	777 E 12TH ST #1-20	90021	14	123A211    59	5132010036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.03264	-118.25093	Plan check for T24 only changing fixtures with existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46990	14041-20000-10121	19647 W ROMAR ST	91324	12	204B117   356	2726010019	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.2547	-118.56191	pv1 single family dwelling. total system size 6kw ac using transformerless inverter. nonstandard plan. 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46991	12041-70000-29933	13455 W MAXELLA AVE Electrical-Room D	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM			PC Info Complete	12/12/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	Install a new 800 meter main section in  electrical room D, connect to the existing 800 ampere busway.  Other work to be done by others.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46992	12041-10000-22152	14654 W NORDHOFF ST	91402	7	198B149   579	2651011005	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Apartment			09/18/2012 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.23522	-118.45198	New 28 units appartment BLDG. new service, panels, and ckts. EPC is for power and energy. (Fire Alarm variance on file)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46993	13041-10000-19475	5710 N LASAINE AVE	91316	5	174B133   355	2254035020	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Expired	08/18/2015 12:00:00 AM	ADDRESS	34.17448	-118.51029	PV1.  Install 3.675 kW DC roof-mounted solar array, interconnect with main service panel.  {Transformerless inverter: SolarEdge SE3800A-US} {15 modules: Trina Solar TSM-245PC05/PA05.18}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46994	18041-10000-24865	375 N FORDYCE ROAD	90049	11	138B141   312	4429019035	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM			PC Approved	11/28/2018 12:00:00 AM	ADDRESS	34.07365	-118.47167	PC FOR POWER ONLY, NEW SFD WITH ATTACHED GARAGE. SERVICE SIZE IS 600A, 240V, 1PH.BUILDING PERMIT # 16010-10000-04511	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
46995	10041-20000-09518	7422 W MELROSE AVE	90036	5	141B181   602	5526019028	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM			PC Approved	11/10/2010 12:00:00 AM	PIN	34.08334012	-118.35179976	revise aome lighting delta 1 only to existing plans and permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46996	18041-10000-01588	11800 N ZELZAH AVE	91344	12	216B125   238	2601018056	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.28704	-118.52676	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.64KWdc / 3.8KWac.(16)MODULES-SOLARWORLD 290(16)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46997	18041-20000-46420	22632 W CALVERT ST pv1	91367	3	177B097   423	2039017016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.18087	-118.62005	pv1install roof mounted pv system sized 9.4KW AC interconnected with msp with (1) tesla poerwall 5KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
46998	17041-20005-04959	10402 N SEPULVEDA BLVD bldg 2	91345	7	207B145   772	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	PIN	34.26013947	-118.46578964	11/6/2017plan check for power only, first time tenant.this is plan check only.permit fees paid under master permit.((((PLAN CHECK FOR T-24 ONLY. SCOPE INCLUDES (DELTA 1 AND 2) CHANGES TO FIXTURES AND REVISIONS TO T-24 FORMS ORIGINAL 17041-10000-04959Plan check for Title 24 only T.I. existing sapce  retail. Total area: 2,705 sq ft.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
46999	10041-10000-03395	2201 S SAN PEDRO ST	90011	9	120A209    13	5127007024	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	02/25/2010 12:00:00 AM		Permit Finaled	05/10/2010 12:00:00 AM	ADDRESS	34.02483	-118.25946	CHANGE PORTION OF EXISTING 1-STORY, TYPE V-B BLDG, 56' X 19.5', FROM RETAIL TO RESTAURANT (M TO B OCCUPANCY;TAKE OUT ONLY) plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47000	12041-10000-27046	735 S FIGUEROA ST SUITE 115	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	PLAN CHECK FOR T24 (COMMERCIAL) AND EMERGENCY LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47001	12041-10000-16570	4411-4413 W SANTA MONICA BLVD	90029	13	145-5A201 499	5542024040	[Q]C2-1VL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.09102	-118.2849	Change the use from duplex to office.  Change to lighting using all existing circuits.  No new load, per applicant.  PLAN CHECK ONLY for Energy, NO Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47002	14041-20000-33690	21501 W VENTURA BLVD	91367	3	171B105     7	2168027031	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	PIN	34.16881252	-118.59888323	TI TO AN EXISTING COMMERCIAL SINGLE STORY BUILDING.  ADDING NEW LIGHTING TO EXISTING POWER PANELS.  PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING.  INDOOR/OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47003	13041-10000-11450	6701 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	33.93211	-118.40783	PC FOR ENERGY. INSTALLING NEW COOLERS AND EXPANDING A COOLER. 19 lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47004	19041-30000-25436	2049 S CENTURY PARK EAST 35th FLLOB	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	ENERGY PC FOR T. I. RENOVATION TO PUBLIC ELEV. LOBBY.  AREA 295SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47005	15041-20000-30049	2111 N CAHUENGA BLVD BLDG 2	90068	4	151-5A187 288	5576003043	R3-1	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			09/11/2015 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.1091	-118.33132	Plan check for new 9 units Townhome 600A Service Building 2. No commom area.Note: There are 2 building on this parcel, the building is mirror image of each other.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47006	19041-30000-11202	4114 N VANTAGE AVE	91604	2	165B165  1163	2367014027	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	06/18/2020 12:00:00 AM	ADDRESS	34.14533	-118.39744	Plan check for a fire alarm system for a 4-story, 18-unit apartment building. Fire alarm system consists of (1) FACP and (69) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47007	18041-10000-47209	915 W WILSHIRE BLVD # 850	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.05069	-118.2599	TENANT IMPROVEMENT IN OFFICESUITE 850NEW CIRCUITS AND LIGHTING PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47008	13041-10000-02295	8495 W 3RD ST D104	90048	5	138B173   683	5511013021	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.07352	-118.37624	TI for restaurant. Plan check for energy less than 400A. 1428 sqrft. WhichWich? store #197.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47009	12041-10001-09312	4020 S LINCOLN BLVD UNIT A	90292	11	108B149  1249	4230002013	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM			PC Approved	05/14/2012 12:00:00 AM	ADDRESS	33.99001	-118.44704	PLAN POWER AND ENERGY FOR FIRST TIME TENANT (JERSEY MIKE'S). EXISTING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47010	13041-20000-21063	5656 N HAZELTINE AVE 1-26	91401	2	174B153   570	2246032008	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM			Verifications in Progress	09/17/2014 12:00:00 AM	ADDRESS	34.17331	-118.43954	**9/17/2014- NO LONGER AN APARTMENT COMPLEX, NOW EACH UNIT IS CONSIDERED A STAND ALONE SINGLE FAMILY DWELLING WITH ITS OWN ADDRESS. PLAN CHECK NO LONGER REQUIRED DUE TO SERVICE SIZE LESS THAN 400AMPS PER HOME**NEW 26 UNIT APARTMENT BUILDING. 2 SEPERATE 600AMP SERVICES AT 2 SEPERATE LOCATIONS UNDER THE SAME ADDRESS. DWP SERVICE APPROVAL IS STILL PENDING. CHECK FOR MISSING PAGE. PAGE INSERTED IN MIDDLE OF ROLL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47011	15041-20000-19371	8310 S VERMONT AVE	90044	8	097-5A199  20	6032009916	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	33.96299	-118.29133	Plan check Title 24 only for existing SUBWAY for T.I. Total area: 1,144SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47012	16041-10000-35691	1344 W 41ST ST	90037	9	114B197   514	5020003009	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.00891	-118.29957	PV1 roof mounted solar system installation to a single family home. Installing a central inverter rated at 3.8 KW with 18 solar modules and its respective optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47013	18041-10000-19592	1714 N MCCADDEN PL 1-218	90028	13	148-5A185  86	5547010019	(Q)C4-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			05/25/2018 12:00:00 AM			PC Info Complete	05/25/2018 12:00:00 AM	ADDRESS	34.1021	-118.3373	PC FOR APT LOBBY/ OFFICE &LOUNGE REMODEL IN APARTMENT BUILDING FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 2596 SQ.FT. B#17016-20000-38427	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47014	15041-20000-26070	1880 S CENTURY PARK EAST Suite 1000	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,258 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47015	14041-10001-05684	1434 N BENTON WAY	90026	13	142-5A205 332	5424016012	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.08429	-118.26789	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(17) MODULES: CANADIAN SOLAR CS6P-250PX(1) SOLAREDGE SE3800A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47016	09041-10002-07175	8330 S VERMONT AVE	90044	8	097-5A199  47	6032009908	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM			Verifications in Progress	06/10/2010 12:00:00 AM	ADDRESS	33.9627	-118.29134	DELTA 1  REVISIONS- CHANGING SOME LUMINAIRESPLAN CHK IS FOR TITLE 24 ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47017	18041-10000-18389	7426 S ALVERSTONE AVE	90045	11	102B165   621	4110004041	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	33.97388	-118.39697	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 4.20KWdc / 3.92KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER. (14)MODULES-SOLARWORLD  SW-300(14)OPTIMIZERS-ENPHASE S280--60-LL-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47018	18041-20001-31138	310 N CARMELINA AVE	90049	11	135B141   814	4405003001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	34.06215	-118.48478	1/16/2019changes to an approved set of plans.  canges to relocate existing generator from side of property to rear of property.  this is plan check only.  ((((Plan check for installation of 600A  Automatic Transfer Switch(ATS) for new generator.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47019	18041-20001-24233	21300 W HART ST	91303	3	183B105   690	2138016015	MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM			PC Approved	07/13/2018 12:00:00 AM	ADDRESS	34.19728	-118.59574	Expedited plan check fee. PV2.  Install 20 kW roof mounted grid-tied PV system. (68) modules with (2) 10kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47020	17041-20000-31296	12229 W VENTURA BLVD	91604	2	162B165    37	2367017017	C2-1L-RIO, P-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	05/17/2018 12:00:00 AM		Issued	05/17/2018 12:00:00 AM	ADDRESS	34.14336	-118.39949	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,593 sq. ft.Note: Building application has been generated under 17016-20000-25182	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47021	12041-20000-29214	6640 N VAN NUYS BLVD #203	91405	6	180B149   272	2237001018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.19188	-118.44844	Change to lighting in an existing 2-story office building.   Load is less than 40 amps per applicant.  PLAN CHECK ONLY for Energy, with NO Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47022	10041-10000-16474	1507 N ECHO PARK AVE	90026	13	141A209   310	5419015004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM			PC Approved	08/25/2010 12:00:00 AM	ADDRESS	34.08016	-118.2554	TI IN AN EXISTING OFFICE AREA. PLANN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47023	18041-10000-44461	5023 W WASHINGTON BLVD	90016	10	126B181   908	5067015901	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.04092	-118.34934	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47024	18041-10000-19918	14853 W STRATHERN ST	91402	6	189B149   279	2209039009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.21621	-118.45704	PC FOR ROOF MOUNTED PV SYSTEM ON SFD. SCOPE INCLUDES 18 MODULES WITH SINGLE CETRAL INVERTER. TOTAL SYSTEM SIZE 5.31KWDC /5.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47025	19041-10000-23867	722 S BROADWAY	90014	14	127-5A211  87	5144015034	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	07/14/2021 12:00:00 AM		Permit Finaled	08/22/2023 12:00:00 AM	ADDRESS	34.04439	-118.25365	FULL PLAN CHECK FOR A CORE AND SHELL ALTERATION OF AN EXISTING HISTORIC, EIGHT STORY BUILDING HIGH RISE (NO CHANGE OF USE). FULL NEW ELECTRICAL SYSTEM WITH 2000A SERVICE AND 2500A PULL SECTION. SCOPE INCLUDES NEW 75HP FIRE PUMP AND A 200KW EM GENERATOR. TOTAL AFFECTED AREA IS 65688 SQ.FTB#17016-10000-14872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47026	16041-20001-00521	13032 N ANGELES TRAIL WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.30923	-118.40436	EXPEDITE PER APPLICANT REQUEST[Install a roof mounted solar array on a SFD. Interconnect with 200A MSP, derating main to 175A.New 3kW ungrounded inverter using 300W power optimizers. There is an existing solar system on roof rated 4.2kW. System size: 3kW (new) + 4.2kW (existing) = 7.2kW.(11) 265 pv modules, one optimizer each.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47027	14041-10000-33759	12508 W OSPREY LANE 1-3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	33.97856	-118.41138	Install (N) fire alarm system with (50) notification and initiating devices for multifamily dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47028	18041-10000-15326	355 S GRAND AVE 20TH FLR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR TITLE 24 ONLY . CORRIDORS AND ELEVATORS LOBBY - TOTAL AFFECTED AREA = 2181 SQ. FT.   building permit # 17016-10000-35283	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47029	15041-10001-17438	8500 W BEVERLY BLVD Space #691	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	Change to approved set by changing the lighting floor plan. All changes are under delta-4 only.(((Energy plan check for a retail (Footlocker) T.I located in Beverly Center. Scope includes new lighting, equipment, and receptacles)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47030	13041-10000-09576	11280 W OLYMPIC BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.03823	-118.44069	PLAN CHECK FOR ENERGY ONLY FOR EXISTING STARBUCKS COFFEE. 1420 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47031	10041-20001-25707	9341 N SEPULVEDA BLVD 1-4	91343	7	198B145   189	2656018034	R3-1	North Valley	Mission Hills - Panorama City - North Hills			1172.01	Electrical	Electrical	Apartment			04/01/2011 12:00:00 AM			PC Approved	04/01/2011 12:00:00 AM	ADDRESS	34.24039	-118.468	Plan check for revision to New fire alarm plan check. Delta 1 revision to indicate FPLR type conductor installation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47032	14041-10001-03140	3045 E 12TH ST	90023	14	118-5A223  52	5169005002	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM			PC Approved	01/02/2015 12:00:00 AM	ADDRESS	34.01956	-118.21426	(((1/2/2015))) Title 24 only.  Supplemental application for plan check only.  Original electrical permit issued before title 24 part 6 July 1st effective date.  Total area = 10,900 sq. ft.  New 400 A service, 5 new panels, new lighting and recepticles.-----Previous work description-----TENANT IMPROVMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47033	13041-10000-10522	8330 W FOOTHILL BLVD	91040	7	204B189    50	2560008001	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			Reviewed by Supervisor	05/16/2013 12:00:00 AM	ADDRESS	34.25948	-118.31453	T.I. DENTIST/ MEDICAL OFFICE (CHANGE OF USE FROM MIXED USE BLDG). PLAN CHECK FOR POWER AND ENERGY. 14,711 SQ. FT. NOT OSHPOD3 REQUIRED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47034	16041-10000-42688	2710 S SEVERANCE ST	90007	9	121-5A201  14	5123003415	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.02896	-118.28161	PC for a new fire alarm system to a 2 story building at USC. Scope includes (110) Fire alarm devices,  and (4) FA panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47035	18041-10000-39133	2231 S WESTERN AVE	90018	10	123B193   238	5058009041	C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	06/26/2020 12:00:00 AM	ADDRESS	34.03519	-118.30929	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP AND 182 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47036	12041-20000-15607	1540 E ALCAZAR ST 2nd floor-rooms	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			PC Approved	07/05/2012 12:00:00 AM	ADDRESS	34.06338	-118.20434	T-24 lighting plan check for alteration to interior lighting in rooms 211 , 219, 221, 224, 225, 233A, and 233-D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47037	19041-10000-00335	8140 S VERMONT AVE	90044	8	099B197  1255	6032005021	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Issued	01/04/2019 12:00:00 AM	ADDRESS	33.9644	-118.29132	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47038	10041-20002-09845	15031 W RINALDI ST cancer-treatment	91345	7	213B145    64	2664022022	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM			PC Approved	08/09/2010 12:00:00 AM	ADDRESS	34.27918	-118.46029	Revision to approved plans. Change location of routing to power conditioner and to power panel for linear accelerator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47039	17041-10000-41851	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			PC Info Complete	12/01/2017 12:00:00 AM	ADDRESS	34.04443	-118.29612	T-24, Scope of work includes new lighting in two storage areas. Total sq. ft. 287.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47040	12041-10000-11344	6158 N DEBS AVE	91367	3	177B089   290	2033025013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.1828	-118.64866	Plan check for roof mounted 9.156KW photovoltaic system (transformerless inverter). single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47041	16041-10000-39658	1205 E 6TH ST	90021	14	126A215   332	5164009012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.03828	-118.23807	PC FOR FA SYSTEM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47042	14041-20000-03471	5187 N CHIMINEAS AVE	91356	3	171B125   398	2181006021	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.16533	-118.52821	"New roof mounted PV system with 15.39 KWdc.""$0 permit fee due to senate bill 1222 from 2012"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47043	11041-20000-03491	16710 W VENTURA BLVD 1-125	91436	5	168B137   335	2289020019	(Q)C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Apartment			02/23/2011 12:00:00 AM	04/15/2011 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.15819	-118.49729	Plan check for new roof mounted 167.6KW photovoltaic system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47044	16041-20000-41294	8724 N BRADLEY AVE	91352	6	195B173   459	2408026035	[T][Q]M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	12/12/2017 12:00:00 AM		Issued	12/12/2017 12:00:00 AM	ADDRESS	34.22816	-118.37405	Service upgrade to (E) commercial building.  (2) services per LADWP - Variance has been submiited with letter from utility forthcoming and to be presented prior to approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47045	15041-10001-18346	14960 W OSWALD ST	91342	7	222B149   998	2506007011	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.30192	-118.45852	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1 INSTALL 4.578 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(14) MODULES: SUNPOWER SPR327NE(1)INVERTER: POWER ONE PVI -4.2-OUTD>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47046	16041-20000-36394	1575 N GOWER ST 3rd Floor	90028	13	148-5A189 330	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Issued	10/13/2016 12:00:00 AM	ADDRESS	34.09907	-118.32257	Plan check for Title 24 only. Project site is the third floor of an existing commercial high-rise building. Project scope is lighting within the corridors. Total lighting area = 1,056 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47047	19041-10000-15365	5905 W GRACIOSA DR	90068	4	153A191   344	5580011015	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.11285	-118.31824	NEW 4.56 KW ROOF MOUNTED PV SYSTEM WITH 16 PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47048	17041-10002-42324	11904 W TENNESSEE PL	90064	11	123B149   896	4259033002	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.03044	-118.44985	Supplemental for fee expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47049	18041-20001-00368	2122 S GUTHRIE DR	90034	5	126B165   196	4309015024	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/15/2018 12:00:00 AM	ADDRESS	34.04378	-118.3943	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM ON STAND ALONE GARAGE WITH LIMITED SETBACKS. SYSTEM SIZE: 5KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47050	16041-10001-05433	8400 N BALBOA BLVD north bldg	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM			PC Info Complete	02/22/2017 12:00:00 AM	ADDRESS	34.22376	-118.50243	CHANGES TO APPROVED SET. PROVIDE NEW LIGHTING FOR TRASH AREAS AND PROVIDED ONE MORE ADDITIONAL TENANT SPACE. ALL CHANGES CLOUDED DELTA 2 ON PLANS. PERMIT TO BE ISSUED FOR ADDED WORK.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47051	17041-20002-43270	1475 S BEVERLY DR 1-18	90035	5	129B165   154	4306009031	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.05296	-118.39563	Revisions to approved set of plans.  Minor SLD revisions.  $0 plan check fee per State Senate Bill SB 1222. (((PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22 KW.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47052	19041-20000-50841	14378 W VENTURA BLVD	91423	4	165B153   358	2266002054	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	01/06/2020 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.15012	-118.44574	Power and energy for medical office.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47053	19041-10000-09799	11700 N CORBIN AVE	91326	12	216B113     1	2701002068	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South, Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	05/24/2021 12:00:00 AM		Permit Finaled	10/19/2023 12:00:00 AM	ADDRESS	34.28162	-118.57177	Title 24 - Plan Check. Installation of private tract site lighting in new development  (Tract No. 50509-01) Ligting area = 307,865.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47054	17041-20000-14346	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Issued	08/30/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for energy only. New outdoor lighting installed under solar carport, located on roof of parking garage (at the Northridge Fashion Center).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47055	19041-10001-39126	17431 W RAYEN ST	91325	12	195B129   204	2768019001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	34.23231	-118.51485	EXPEDITE FEESPV1, NEW ROOFTOPMOUNTED SYSTEM, SYSTEM SIZE IS 21.3KWdc/17.4KWac. SCOPE OF WORK IS 60 MODULES (SOLARIA POWER XT-355R-AC) WITH MICROINVERTERS (ENPHASE IQ7PLUS) LEADING TO A 200A LOAD CENTER. PANEL UPGRADE TO BE SEPARTELLY PERMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47056	17041-10000-40255	950 W WASHINGTON BLVD	90015	1	124-5A203  17	5124016028	(Q)CM-1-HPOZ, (Q)CM-2-HPOZ, (Q)P-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.03731	-118.27895	PV2 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER WITH SOLAR OPTIMIZERS. (33) MODULES, (1)14.4KW AC INVERTER, TOTAL SYSTEM SIZE IS 14.4KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47057	15041-10000-08465	758 N CAHUENGA BLVD	90038	13	141B185   271	5533032001	CM-1VL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			Reviewed by Supervisor	04/24/2015 12:00:00 AM	ADDRESS	34.0851	-118.3286	3 STORY OFFICE & SOUND STUDIO BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47058	18041-20000-37164	232 E 2ND ST Unit F	90012	14	129A213    19	5161024034		Central				2062.00	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.0495	-118.24258	First time tenant to commercial space in mixed-use building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47059	17041-10000-15761	3344 S LA CIENEGA BLVD	90016	10	120B173   249	5048016026	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.02695	-118.37186	PC FOR ENERGY ONLY. TI. CONNECTED LOAD < 400 AMP. TOTAL AREA 5665 SQ FT.B # 17016-10000-11668	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47060	14041-20000-24393	7057 N CALHOUN AVE	91405	6	183B153   373	2217017001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.19912	-118.44231	PV1 SFD. TOTAL SYSTEM SIZE 5.18KW AC USING MICROINVERTER. USING STANDARD PLAN. USING ENPHASE M215. TOTAL OF 24 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47061	19041-20000-49821	5127 W FRANKLIN AVE	90027	4	150A195   127	5589008002	RE9-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.10552	-118.30142	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 9.66 KW DC/8.96 KW AC. SCOPE OF WORK CONSISTS OF (28) PV MODULES WIITH MICROINVERTERS AND A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47062	14041-20001-10882	6505 N LUBAO AVE	91367	3	180B113   654	2134039019	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.18857	-118.56835	Fee for expedite*****Roof mounted PV system with Optimizer, system size 4.5KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47063	16041-20000-17457	11761 W ROSCOE BLVD	91352	6	192B169   438	2633031902	[Q]PF-1XL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1218.02	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Issued	08/31/2016 12:00:00 AM	ADDRESS	34.22177	-118.38982	PV2. ROOFMOUNTED SOLAR SYSTEM. USING (290) MODULES AND (3) ABB TRIO 27.6 INVERTERS  SYSTEM SIZE: 83KW  SYSTEM.Note: Fees are $0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47064	18041-10000-38758	13520 W SATICOY ST	91402	6	186B157   154	2303024018	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.20905	-118.42755	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47065	18041-30000-46995	2002 S SAWTELLE BLVD	90025	11	126B153   676	4261032054	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.04089	-118.44337	PC FOR T-24 ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING TO A RESTAURANT TI. TOTAL SQ. FT. 728. INSPECTION FEES HAVE BEEN PAID FOR IN PERMIT # 18041-30000-14375	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47066	17041-10000-39222	1055 N ALEXANDRIA AVE	90029	13	144B197   880	5538002034	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.09011	-118.298	PC for T24 only for outdoor lighting. Replacing existing fixtures with LED fixtures. Total 4900sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47067	17041-20000-15819	21820 W BURBANK BLVD Ste 150	91367	3	174B105    44	2146007121	PK(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.17228	-118.6032	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47068	14041-10000-11323	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			04/29/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.04594	-118.25757	PC FOR FIRE ALARM SYSTEM. NEW MIXED USED APARTMANT BUILDING. NO OF FIRE ALARM  DEVICES 2557 AND 6 PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47069	11041-10000-08936	303 S LA BREA AVE	90036	4	135B181   192	5508001032	C2-1	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.06866	-118.34435	NEW METHANE MITIGATION AND DETECTION SYSTEM IN A BRAND NEW COMMERCIAL 2-STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47070	08041-10002-02697	8231 W 3RD ST	90048	5	138B173   815	5511018020	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM			PC Approved	08/02/2010 12:00:00 AM	ADDRESS	34.07272	-118.36914	Change the priviously approved Plan . Remove the shunt trip for elevator. Plan check for the change. (((((((((((((((((((((((((New mixed used commercial building.   open gargae, 1 story of retail, 2 upper stories office.  Plan check for power (Core and shell only) and energy only. Note: EPC under 2008 L.A. elect. code.Fully rated system , undergorund 1200 Amp service- Methane zone.  Report is provided and signed ( attached to plan) .  Tenanats need to submit for plan check.))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47071	18041-10000-13789	4525 W WILSHIRE BLVD Suite #100	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	PLAN CHECK FOR FIRE ALARM TI IN TENANT SPACE (WORKSHOP CREATIVE).  SYSTEM CONSISTING OF 1 POWER SUPPLY   AND 54 DEVICES ON EXISTING FACP UNDER PERMIT # 17041-10000-21560	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47072	16041-10000-27968	5200 W WILSHIRE BLVD	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Closed	12/08/2017 12:00:00 AM	ADDRESS	34.06194	-118.3435	"FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A NEW BUILDING. CORE AND SHELL WAS PULLED UNDER SEPARATE PERMIT (10041-20000-20309). TI FOR A NEW RESTAURANT ""HUNGRY TRADER"". SCOPE INCLUDES 3 NEW SUBPANELS, ONE TRANSFORMER, AND NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2453 SQ. FT. B#16016-10000-18253"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47073	14041-20000-17621	768 S CERES AVE	90021	14	124-5A213 495	5146003033	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.03626	-118.24463	New industrial building.  New 400A service, panels, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47074	14041-20000-15558	1420 S FIGUEROA ST	90015	14	126A205   166	5134009019	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.03815	-118.26937	Plan check for revision to approved set of plans reference 13041-10000-20342.remove equipment form one panel to another delta 5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47075	11041-10000-21950	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM	09/21/2012 12:00:00 AM		Issued	09/21/2012 12:00:00 AM	ADDRESS	33.77884	-118.29327	Medium voltage, addition of new skid, new pumps, and other equipment , non classified area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47076	12041-10000-27058	7418 W 91ST ST	90045	11	093B157    60	4119015014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	33.95425	-118.42515	PV1 3.43 KW ROOF-MOUNT ENPHASE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47077	16041-20000-25287	16814 W MAYALL ST	91343	12	204B137   751	2685003003	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.25373	-118.49867	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system. (32) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47078	17041-20000-46115	11612 W DILLING ST	91604	2	162B169   194	2368008002	RE11-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2017 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	02/10/2018 12:00:00 AM	ADDRESS	34.14296	-118.38593	Plan check for the addition of a Tesla PowerWall onto an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47079	14041-10001-10252	11410 W DONA LOLA DR	91604	2	159B173   406	2380017016	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.13223	-118.37929	((EXPEDITE FEES))PV1 FOR ROOFMOUNTED SYSTEM. TOTAL SYSTEM SIZE 11KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47080	16041-20000-44273	1532 W CAMBRIA ST	90017	1	130-5A205 111	5142023010	R4-1	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			12/16/2016 12:00:00 AM			PC Info Complete	04/20/2017 12:00:00 AM	ADDRESS	34.05255	-118.271	new 40 unit apartment building 1600 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47081	16041-20002-21501	16912 W SAN FERNANDO MISSION BLVD	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.27132	-118.50023	Revisions to approved set.  Delta 3 revisions showing new proposed rooftop conduit routing with ampacity correction calculation included to justify conductor size.  (((PLANCHECK FOR POWER AND ENERGY. SERVICE UPGRADE AND TENANT IMPROVEMENT FIR URGENT CARE MEDICAL CLINIC.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47082	12041-20000-08311	57 E MARKET ST	90291	11	108A143   429	4226007009	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM			PC Approved	04/13/2012 12:00:00 AM	ADDRESS	33.98811	-118.47335	Plan check for energy efficiency standards and emergency egress/exit lights, load < 400A.(INTERIOR TI AND ADD NEW 2ND FLOOR STORAGE AREA WITHIN EXIST BLDG.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47083	18041-10000-03953	5822 S VERMONT AVE	90044	9	108B197  1460	6004001031	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			PC Info Complete	04/24/2018 12:00:00 AM	ADDRESS	33.9889	-118.28954	PC for T24 only for outdoor canopy lighting. Installing new lights. Total area is 7105sqft. B# 18016-70000-02970. This permit encompasses three different buildings under 18041-10000-03957 and 18041-10000-03959.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47084	13041-20001-00424	11754 W TERRA BELLA ST	91342	7	213B169   586	2530002026	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.04	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2013 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	ADDRESS	34.27978	-118.38865	INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM using enphase M215 inverters with monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47085	19041-20000-36331	700 S FLOWER ST STE 2600	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	T24 PLAN CHECK, ENERGY ONLY, FOR A TI TO AN EXISTING COMMERCIAL HIGH RISE OFFICE ON THE 26TH FLOOR. LIGHTS AND OUTLETS ONLY TOTAL SQUARE FOOTAGE = 8777 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47086	10041-20002-17894	11723 N FENTON AVE	91342	7	213B165   170	2531009041	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1041.03	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM			PC Info Complete	02/11/2011 12:00:00 AM	ADDRESS	34.28324	-118.39296	Supplemental from previous approved plans.  Additional lights at for parking lots.  Plan check for energy only.  Note: Permit is under 10041-20000-17894*****Plan check T-24 Energy for outdoor parking lot lights and externally illuminated sign lighting only.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47087	18041-20000-16471	14906 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29409	-118.45517	Plan check for PV roof mounted system, System size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47088	14041-20000-10784	12500 N GLADSTONE AVE	91342	7	219B161   168	2525019062	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.29734	-118.41327	Install 800A panel board to supply two chillers with an kirk key interlock (one of the chillers is existing).  Only one chiller be operated at at time.  Also install 40 Hp motore for the chillers.  Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47089	16041-10000-41740	11111 W SANTA MONICA BLVD 900	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.04771	-118.44481	T-24, PC FOR ENERGY ONLY. INTERIOR T.I. WORK ON 4,438SF OF TOTAL FLOOR SPACE  IN EXISTING OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4358 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47090	12041-10000-15373	3664 N BEVERLY RIDGE DR	91423	5	162B149   520	2274020014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.13763	-118.44741	Plan check for new roof mounted 6.63KW Photovoltaic System single family dwelling using transformerless inverter. Permit for PV system and includes fees for new service and service panel upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47091	18041-10002-20342	6505 S ESPLANADE #4	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	33.96159	-118.45071	Change to approved set by changing the inverter from 3.3kw to 3.8kw. All changes under delta-2 only.(((PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW LOAD CENTER, 6 MODULES(#SC325) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 1.95KWdc. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47092	14041-20001-08347	20932 W CANTARA ST	91304	3	189B109    55	2109007028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.21816	-118.5899	Expedited plan check fees per applicant request.  (((PV1.  Intall for 4kw roofmounted PV system, interconnected with main pannel. Transformerless inverter with power optimizer; Solaredge SE3800A, 16 modules Canadian Solar CS60-250PX.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47093	14041-20000-04532	1525 N LA BREA AVE STE 205	90046	4	147B181   557	5548011039	[Q]C4-2D-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	PIN	34.09870722	-118.34476326	plan check for energy plan check thai massage; All work will be interior	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47094	14041-20000-34395	777 S FIGUEROA ST 13TH FLOOR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.04828	-118.26116	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. ADDING LIGHTING AND BRANCH CIRCUITS TO EXISTING PANNEL. PLAN CHECK FOR TITLE 24 ONLY AND EMERGENCY LIGHTING. TOTAL SQFT. 1842	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47095	17041-10000-09754	1536 S SELBY AVE	90024	5	132B153   860	4325029017	[Q]RD1.5-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.05478	-118.4372	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 25650 SQ. INDOOR/OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47096	11041-10000-17308	11285 W SANTA MONICA BLVD	90025	11	129B149   809	4261007031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.04671	-118.44821	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47097	14041-10000-21173	5249 N LOLETA AVE	90041	14	163-5A227 155	5669011015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			Reviewed by Supervisor	08/15/2014 12:00:00 AM	ADDRESS	34.14273	-118.19827	PV1, INSTALL 4.08 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47098	06041-10012-23224	6250 W HOLLYWOOD BLVD	90028	13	148-5A189 132	5546029917	[T][Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	03/11/2010 12:00:00 AM		Permit Finaled	03/16/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	Revisions to approved set of plans- Delta 30-  REVISIONS OF SOME CIRCUIT DESIGNATIONS; NEW CIRCUITS TO PANEL L10H2, PANEL EL7H  AND PANEL EL2ACT; DELETED SOME CIRCUITS AND REVISED LOAD CALCULATIONS FOR THE PANELS;RELOCATED PANELS AND XFMR FROM 9TH FLOOR TO 10TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47099	10041-10000-03331	10345 W WILKINS AVE	90024	5	132B157    68	4327010012	[Q]R3-1-O	West Los Angeles	Westwood			2657.00	Electrical	Electrical	Apartment			02/25/2010 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.06158	-118.42489	PLAN CHECK POWER AND ENERGY FOR NEW FOUR STORY 16 UNIT APT OVER BASEMENT GARAGE. 1 TYPICAL UNIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47100	11041-20000-00963	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	T.I. to existing building.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47101	18041-20000-05391	22351 W VENTURA BLVD	91364	3	174B101   472	2146012015	C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM			PC Info Complete	08/09/2018 12:00:00 AM	ADDRESS	34.16907	-118.61427	New service station with retail and restaurant tenant spaces.  Site lighting and TI for retail - restaurant TI under separate permit.  800 A 208Y/120V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47102	13041-10000-05614	4206 S LINCOLN BLVD	90292	11	105B153    48	4230001019	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	33.9868	-118.4441	T24 LIGHTING FOR PHYSICAL THERAPY/OFFICE SPACE. SQRFT: 2455. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47103	11041-20001-20870	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.02174	-118.39786	"CHANGES MADE TO APPROVED SET OF PLANS. SERVICE UPGRADED TO 3000A WITH NEW SWITCH BOARD.  Plan check only for ""Delta 8"". <<<<New 131 unit, 6-story apartment building, with 3 levels of underground parking.  Fees calculated per customer application.  Plan check for Power and Energy.  A variance to seperate the fire alarm system from the electrical system was submitted on May 24, 2012.>>>>>."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47104	16041-20000-38145	4960 N STERN AVE	91423	4	171B153   825	2269020023	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.16102	-118.43435	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (37) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47105	17041-20000-27578	3443 S SEPULVEDA BLVD	90034	5	117B157   113	4251015006	C2-1VL, R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.01969	-118.4228	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from a super market to art studios/tenant improvement. Total lighting area = 36,199 sq. ft. Power work exceeds 400 amps. Note: Building application has been generated under 17016-10000-12365	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47106	11041-20000-20841	10210 W CIELO DR	90210	5	147B153   233	4357015014	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.09552	-118.43571	New 10.75 KW roof mounted pv system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47107	14041-10000-15433	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Expired	12/07/2016 12:00:00 AM	ADDRESS	33.79173	-118.23549	PLANCHECK FOR POWER. UGRADE MAIN OFFICE POWER DISTRIBUITION MCC-88. AT TESORO LOS ANGELES REFINERY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47108	13041-20001-34231	17822 W GREYHAWK PL	91344	12	216B129   280	2601066002	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.28732	-118.52047	New 12.48 kw rooftop pv system for an existing sfr.  System is UNGROUNDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47109	18041-10001-05055	9800 S LAUREL ST	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.94799	-118.23082	PC FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS COVERING A NEW HOUSE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47110	19041-10000-19118	8235 N WYNNE AVE	91335	12	192B125   701	2102022024	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.22045	-118.53024	pc for 4.65kw pv system, system consists of  15 modules with microinverter, 1 combinerbox.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47111	19041-20001-44242	7600 N BALBOA BLVD 111	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	FULL PLAN CHECK FOR FIRST TIME TENANT. INSTALL NEW PANELS, EQUIPMENTS. INSPECTION FEE UNDER 19041-20000-44242	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47112	15041-10000-02624	10960 W WILSHIRE BLVD	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	34.058	-118.44597	Title 24 plan check only.  Total area = 44,010 sq. ft.T.I. to two floors in existing highrise office space.  Lighting, recepticles, and one new 225 A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47113	12041-20000-31107	3580 W WILSHIRE BLVD Suite 1500	90010	10	132B193   154	5093026033	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.06156	-118.3028	NON-STRUCUTRAL TENANT IMPROVEMENT TO EXISTING OFFICE (13,745 SQ FT) ON 15TH FLOOR: REMOVE AND INSTALL NEW NON-BEARING PARTITIONS, PARTIAL NEW SUSPENDED CEILING, NEW MILWORK, FINISHES; EXISTING DEMISING WALL TO REMAIN.  T-24 and emergency lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47114	18041-20000-06379	18133 W VENTURA BLVD Ste 102	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	12/10/2021 12:00:00 AM	ADDRESS	34.16603	-118.52861	Plan check for power and energy. Project site is an existing commercial building. Project scope is a first time tenant improvement for a medical office. Total lighting area = 7,450 sq. ft.Note: Building application has been generated under 18016-20000-04282	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47115	12041-10000-18682	16052 W FILBERT ST	91342	7	228B141   128	2603023024	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Expired	10/07/2014 12:00:00 AM	ADDRESS	34.32315	-118.4835	Plan check for new roof mounted 8.16 KW (Aurora) transformerless photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47116	16041-20000-31886	14859 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29538	-118.45519	Plan check for roof-mounted solar array on SFD. Interconnect with 200A MSP.3kW ungrounded system. (11) 305W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47117	13041-20000-01812	1342 W ADAMS BLVD	90007	8	123B197   898	5055006011	R4-1L-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Apartment			01/23/2013 12:00:00 AM			Reviewed by Supervisor	03/08/2013 12:00:00 AM	ADDRESS	34.03251	-118.29008	Plan check for electrical. Historical building. Existing apartment renovation. METHANE BUFFER ZONE. Plan check fees per applicant..PLEASE VERIFY FEES DURING FINAL PAY PERIOD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47118	14041-10000-01778	25965 S NORMANDIE AVE A118	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM			PC Info Complete	01/22/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	Replacement of X-ray equipment with reduction in load in medical office building radiology room.    Plan check for Title 24 only due to relocation of 50% of existing fixtures in space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47119	19041-10000-31811	2765 E WABASH AVE	90033	14	130-5A227 296	5177012908	OS-1XL-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2032.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.05072	-118.19815	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47120	15041-10000-25466	10639 N SEPULVEDA BLVD	91345	7	207B145   352	2649012003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.26384	-118.46775	TI PC AT COUNTER T-24 TO DOLLAR TREE RETAIL STORE(1) ADDITIONAL ELECTRICAL PANEL, NEW INTERIOR LIGHTING AND OUTLETS.SQ FT = 12,111	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47121	09041-20001-12208	2701 N SEPULVEDA BLVD	90049	11	156B141    17	4490001015	PF-1XL, RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	1415.00, 2623.01	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.12326	-118.4793	Three story addition of the North Building Complex on top of an existing parking structure.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47122	15041-10000-16899	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Expired	06/30/2017 12:00:00 AM	ADDRESS	34.10137	-118.34182	INTERIOR REWIRE TO A SINGLE UNIT NUMBER 305 IN A HIGH RISE HOTEL PER ADA REQUIREMENT. PLAN CHECK REQUESTED PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47123	19041-20001-04441	8333 N VAN NUYS BLVD	91402	6	192B149   303	2638038002	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			Corrections Issued	06/26/2019 12:00:00 AM	ADDRESS	34.22236	-118.44896	Plan check for lost of aproved set of plans. Fire alarm system. Plan check only, permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47124	14041-20000-10430	12777 W JEFFERSON BLVD 3rd Floor	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	33.9778	-118.41768	T.I. to existing building on the entire 3rd floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47125	17041-30000-14437	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	Plan check for Power and energy wearhouse and office space T.I. new panels, lighting and receptacle. Total newly connected load exceed 400A feed from Existing 800A switch gear. Total area indoor lighting: 249,391 sq ft. B#17041-30000-04976	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47126	16041-20001-25769	10638 W WALNUT DR	91040	7	201B177   126	2542014029	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	34.24983	-118.36185	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.68 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47127	18041-10000-40724	17535 W DONMETZ ST	91344	12	210B129   112	2711007008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.27464	-118.51661	INSTALL 3 NEW 13.5KWH TESLA POWERWALL <<<<NEW 23.465 KW ROOF MOUNTED PV SYSTEM WITH 988 SOLAR PV MODULES ON A SINGLE FAMILY HOME AND 40.5KWH ENERGY STORAGE SYSTEM.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47128	18041-20000-36207	1646 S LA CIENEGA BLVD	90035	10	129B173  1179	5068008012	C2-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			PC Info Complete	09/21/2018 12:00:00 AM	ADDRESS	34.04751	-118.37594	ti to an existing retail psace.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47129	17041-10001-35365	250 N BURLINGTON AVE	90026	13	136-5A207 263	5159009008	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Apartment			10/03/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.06744	-118.26543	Supplemental for expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47130	10041-20000-22064	925 W 34TH ST 4th Floor	90089	8	120A201    20	5039003027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	PIN	34.02383917	-118.28572873	Tenant improvement - plan check T24 Energy (general/emergency lighting) for remodel of Lecture Room #4114, 4115, and 4117	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47131	18041-20000-07868	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			03/05/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/26/2020 12:00:00 AM	ADDRESS	34.16326	-118.37388	Plan check for a fire alarm system for a 7-story building with 2 levels of below grade parking garage. Fire alarm consists of (1) FACP, (2) annunciators, (12) RPSs, and (999) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47132	17041-20000-23704	2800 S CRENSHAW BLVD	90016	10	123B185  1058	5051008019	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.03095	-118.3349	Restaurant TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47133	19041-10000-01662	10346-10350 N LAUREL CANYON BLVD	91331	7	204B157   221	2646004020	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.25838	-118.43143	NEW RETAIL STORE. FULL PLAN CHECK POWER AND ENERGY. NEW 600 AMP SEVICE. 3850 SQR FT.BULDING PERMIT: 18016-20000-41315	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47134	17041-10002-40645	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	34.01366	-118.28294	SEE APPLICATION NOTES!!!!!PC FOR CHANGES TO APPROVED SET FOR TEMP POWER ALL CHANGES MARKED UNDER DELTA 2. SCOPE INCLUDES REVISIONS TO FEEDER SCHEDULES TO REFLEECT ON SITE INSTALLATION. ADDITIONAL PULLBOXES AND SPLICES SHOWN ON THE PLAN. THIS IS PLAN CHECK ONLY. Plan check for Power only, TEMPORARY POWER for the Coliseum. Add (N) 2000A 480/277V dist. board to the existing 5000A service, (7) temp. power panelboards, (3) tower cranes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47135	17041-10000-17275	1156 S VICTORIA AVE	90019	10	129B189   419	5082025021	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.05137	-118.32603	Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  1 new Tesla AC Powerwall 5.8 kVA 13.0 kWH battery and 1 new Solicia 7.6 kWac TL inverter (32 modules).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47136	19041-20000-33161	7343 W 88TH PL	90045	11	096B157   809	4119022024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	11/09/2019 12:00:00 AM	ADDRESS	33.95665	-118.42383	Install 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47137	14041-20000-07483	11372 W DONA LISA DR	91604	2	159B173   512	2380019015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.13075	-118.37796	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING STANDARD PLAN. 2 CENTRAL INVERTERS TRANSFORMERLESS TYPE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47138	17041-20001-24185	5225 N KELVIN AVE	91364	3	171B109   118	2166028030	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.1654	-118.5856	08/11/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,554 sq. ft.*****Previous Work Description*****COMPLETE REWIRE AND PANEL UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47139	14041-20000-02951	11554 N HUNNEWELL AVE	91342	7	213B165   419	2531022034	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Expired	03/09/2016 12:00:00 AM	ADDRESS	34.28035	-118.39682	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47140	18041-10000-42815	1016-1018 S SANTEE ST	90015	14	126A209   230	5145020034	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	02/16/2021 12:00:00 AM		Issued	02/16/2021 12:00:00 AM	ADDRESS	34.03849	-118.25526	PC FOR POWER AND ENERGY. 2 STORY FIRE DAMAGED LIGHT MANFACTURING BUILDING, UPGRADE TO EXISTING SERVICE PANEL TO 800A AND FOR REPLACEMENT OF FIRE DAMAGE POWER AND LIGHTING ON SECOND FLOOR AND ROOF.building # 17016-30000-37116	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47141	16041-20000-19398	3239 N PASADENA AVE Unit A	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	PV2.  Install 1.71 kW DC roof mounted PV system.  (6) modules with (1) 3 kW transformerless inverter with power optimizers.  1 of 3 PV systems proposed for property submitted concurrently.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47142	16041-10000-05131	1206 W SILVIUS AVE	90731	15	006B193    69	7470019003	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	33.71536	-118.30544	PV1, INSTALL NEW 5.98 KW DC / 5.0KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(23) MODULES: KYOCERA KU2606XPA(1) INVERTERS: ABB PVI 5000-OUTD--US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47143	13041-10000-30869	20332 W VIA BOTTICELLI	91326	12	219B113   257	2701059049	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Expired	05/11/2016 12:00:00 AM	ADDRESS	34.29746	-118.57668	PV1, Install 9.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 39 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47144	15041-10000-15030	21355 W SHERMAN WAY Space-7230	91303	3	186B105   631	2111029001	(T)(Q)M1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Expired	07/17/2017 12:00:00 AM	ADDRESS	34.20118	-118.5973	Energy plan check for an retail office T.I  with new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47145	14041-20000-00503	4613 N WOLFE WAY	91364	3	168A109   149	2172013039	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.15383	-118.58903	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47146	16041-10001-13889	641 E 80TH ST	90001	9	099B205   788	6029001023	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM			PC Approved	04/26/2016 12:00:00 AM	ADDRESS	33.96659	-118.26356	PC only under permit 16041-90000-13889.(12) KD255GX-LFB3(1) PVI-3.0-OUTD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47147	19041-10000-15896	3453 S FEDERAL AVE	90066	11	117B157   717	4249021030	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.01472	-118.43063	PV1 WITH ESS. Plan check for 5.76 KW AC / 6.66KW DC roofmounted system with (1)ESS, (1) load center, (1) combiner box, and (18) AC modules interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47148	14041-10000-08776	1935 E 7TH ST	90021	14	124-5A217 213	5164021009	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.03477	-118.2329	PV2 ROOF MOUNTED 3PHASE SYSTEM. TOTAL SYSTEM SIZE 50KWAC.((((((((((    10-17-14  M.Z no fees due to senate bill  #   1222   ))))))))))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47149	13041-10000-25294	7328 N QUARTZ AVE	91306	3	186B117   764	2115009011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.20371	-118.56434	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 12.75KW DC ON NON-STANDARD CENTRIAL INVERTER PLAN IN A SINGLE-STORY HOME. XFORMERLESS SYSTEM. WILL BE UTILIZING LOAD CENTER. DOWNSIZING MAIN BREAKER FOR TIE-IN.  (51) TRINA #TSM-250(2)SOLAREDGE SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47150	19041-20001-47934	7023 N VAN NOORD AVE	91605	2	183B161   443	2327021007	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.19815	-118.41507	12/30/19CHANGES TO APPROVED SET CHANGES TO REMOVING LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47151	15041-20000-19344	9335 N RESEDA BLVD	91324	12	198B125   179	2763004003	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.24004	-118.53628	Plan check for change of use from office to Medical space in existing building. 600A Service, total area: 12,700SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47152	18041-20000-39864	4048 N BALLINA DR	91436	5	165B137   586	2286007017	RE15-1-H	South Valley	Encino - Tarzana	Encino	Yes	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.14446	-118.49038	PV1.  Install 11.4 kW AC roof mounted grid tied PV system.  (40) modules with 11.4 kW rated string inverter.  Reduced rating of main breaker to 175A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47153	14041-20000-05297	7300 N SYLVIA AVE	91335	3	186B117   869	2104029022	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Expired	04/06/2016 12:00:00 AM	ADDRESS	34.20311	-118.5523	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. USING SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47154	18041-20000-02805	4840 S ALLA ROAD	90066	11	105B157   536	4223008005	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	33.98258	-118.42922	Permit 3 of 3 for (3) new 2-story core and shell commercial office buildings.  Building 3 distribution equipment/loads.  Plan check for power and energy.  Bldg permits for the (3) separate buildings are under the following permits:16010-10000-0393516010-10000-0393616010-10000-03937	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47155	16041-20000-40400	19514 W VALERIO ST	91335	3	186B117   988	2116019005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.20413	-118.55846	Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with a 200A MSP.4.86kW ungrounded system. (18) EnPhase S280 microinvrters. (18) 320W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47156	11041-10000-06131	7748 N GRAYSTONE DR	91304	3	189B089   287	2017027009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Expired	06/26/2013 12:00:00 AM	ADDRESS	34.21242	-118.65403	New 16.2 kw PV system for SFD. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47157	18041-20000-21308	820 W COLDEN AVE	90044	8	093A199   129	6054001009	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Apartment			06/07/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	33.94893	-118.29021	Plan check for 800 A Service supply power to State Approved Factory Built Housing Building(3 story 9 units appartment)**STATE APPROVED FACTORY BUILT HOUSING  (FBH) BUILDING **	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47158	17041-20000-04649	11249 W CALIFA ST	91601	2	177B173  1395	2337013011	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Apartment			02/13/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.1777	-118.37637	Plan check for installation of solar pv system, roof-mounted on apartment building (unit #B).3kW ungrounded system. (6) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47159	14041-20000-14635	8931 N STANWIN AVE	91331	6	195B161   467	2627029003	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.23191	-118.41741	4.4KW roof-mounted system with (14) Sun Power modules (SPR-E20-327) and (1) transformerless inverter (Aurora UNI  PVI-4.2-TL-OUTD)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47160	14041-10000-33231	555 W 5TH ST Suite 670	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check for Title 24 only.  Total area 3185 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47161	15041-10000-26872	745 S COLUMBIA AVE	90017	1	130-5A205 193	5142021002	R3-1	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.05167	-118.26946	PV1, ADDING NEW 6.89 KW DC SOLAR ARRAY TO AN EXISTING SOLAR ARRAY SYSTEM ON A SINGLE FAMILY HOME.(26) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47162	18041-10000-47224	15650 W NORDHOFF ST	91343	12	198B141   718	2672009036	[T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.23539	-118.47367	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47163	15041-20000-11763	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.2215	-118.42999	PC FOR POWER TO A NURSE CALL SYSTEM. PC FOR NURSE CALL SYSTEM IT SELF. VERIFY REQUIREMENTS OF ARTICLE 517.123. THIS IS AN OSHPD 3 BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47164	15041-10000-22888	4211 N BARRYKNOLL DR	90065	1	154-5A219 211	5472010012	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM			PC Approved	07/17/2015 12:00:00 AM	ADDRESS	34.11779	-118.22234	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.  (20) KYOCERA 2656ZPA MODULES(1) ABB PVI-5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47165	12041-10000-14703	5817 S CRENSHAW BLVD	90043	8	108B185  1036	4005004020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	33.98847	-118.33114	INTERIOR TENANT IMPROVEMENT OF AN EXISTING Winchell's donut shopPLAN CHK IS FOR TITLE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47166	15041-20000-01102	8501 N VINEVALLEY DR	91352	2	192B177   189	2404016066	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.22499	-118.35487	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.0KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47167	14041-20000-05477	7076 W MAYDOCK PL	91042	7	204B201   440	2565007074	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.25645	-118.28564	Roof mounted PV with optimizers, system size 5KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47168	14041-10000-34503	9140 N JORDAN AVE	91311	12	198B105   162	2746012005	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.23653	-118.60379	ENERGY PLAN CHECK ONLY FOR COMMERCIAL 3723 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47169	15041-20000-09517	1312 N PAVIA PL	90272	11	129B133    50	4425013009	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	ADDRESS	34.05327	-118.50434	PLANCHECK FOR POWER AND ENERGY. SINGLE FAMILY HOME. TWO STORIES. 600 AMP SERVICE. 120/240 SINGLE PHASE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47170	17041-10003-32559	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.06371	-118.2982	Changes to an approved set of palns. All changes are clouded under delta 3. Changes include adding 100A house panelboard and 4 circuits, revising floor plans, and single line diagram.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47171	17041-10000-42235	20808 W HORACE ST	91311	12	207B109    89	2706009014	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.26701	-118.5868	PV1  13kw roof mounted system with (45) modules and  Enphase microinverter connecting through a 100Amp sub panel.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47172	19041-10000-46983	6711 S SEPULVEDA BLVD	90045	11	102B165    39	4110001004	C4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Apartment			11/14/2019 12:00:00 AM	02/03/2020 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	33.97915	-118.39453	PC FOR ANEW FIRE ALARM SYSTEM, SCOPE OF WORK IS ONE FIRE ALARM PANEL, WITH 23 REMOTE POWER SUPPLIES AND ROUGHLY 812 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47173	14041-20000-34385	6929 N HAYVENHURST AVE	91406	6	183B137   328	2225002007	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			Corrections Issued	02/17/2015 12:00:00 AM	ADDRESS	34.19659	-118.49256	Change of use from warehouse to automobile sale/showroom.  New 1200A service and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47174	17041-20000-10926	8715 N TOBIAS AVE 1-27	91402	6	195B149   570	2653003123	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Apartment			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.2286	-118.45189	FIRE ALARM 27 UNIT 4 STORIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47175	17041-10000-37457	1541 W WILSHIRE BLVD SUITE 400	90017	1	132A205   216	5142027025	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Issued	10/18/2017 12:00:00 AM	ADDRESS	34.05529	-118.26949	PC for T24 for new lights in corridor in office TI.  Total are is 196sqft. B# 17016-10000-14948.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47176	19041-20000-09476	2334 N HIGHBURY AVE	90032	14	138A237   162	5221013025	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.07296	-118.16208	Plan check for a PV1 roof-mounted PV system. System size is 5.1 kWdc/4.335 kWac-CEC and consists of (1) 5 kWac-rated inverter and (17)  modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47177	19041-10000-00222	5801 S CENTRAL AVE	90011	9	108B209  1319	5103015033	MR1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.20	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM			PC Info Complete	07/16/2019 12:00:00 AM	ADDRESS	33.99004	-118.25665	Power plan check for a 600-Amp service replacement with multiple new meters, new transformers and new panels also added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47178	19041-10000-41096	7108 N DE SOTO AVE	91303	3	183B109   240	2137020054	QC1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.1994	-118.58825	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47179	10041-10000-01003	1452 W 36TH PL	90018	8	120B193  1484	5041019039	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM	01/20/2010 12:00:00 AM		Permit Finaled	02/01/2010 12:00:00 AM	ADDRESS	34.02177	-118.30178	New fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47180	17041-20001-34460	14325 W JOY DR	91331	6	198B153  1032	2644027244	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24154	-118.44537	Changes to an approved set of plans. Equipment ratings have changed and PV system size is now 3.8 kWac.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47181	14041-10000-11011	10455 N SUNLAND BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.25996	-118.3265	plan check for power and energy. TI to (E) ralphs. >400A connected load. emergency lighting installed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47182	14041-20001-03109	14042 W FOX ST	91340	7	210B153    48	2616003003	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.27621	-118.43956	Changes from previously approved plans.  Relocate main panel and inverter to a new location.  No change in inverter and module model numbers.Note: Permit is under the original application.*****Previous Description*****PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47183	15041-20000-19438	215 N VERMONT AVE	90004	13	138B197   568	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			06/22/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Closed	08/11/2017 12:00:00 AM	ADDRESS	34.07493	-118.29195	PLANCHECK FOR POWER AND ENERGY. NEW APARTMENT.  4-story �55' tall mixed-use apartment type VA over basement parking type 1A. 100 residential units , approximately 4500 sf of retail, and 112 parking stalls. METHANE ZONE.  fIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47184	18041-10000-37010	3821 E OLYMPIC BLVD	90023	14	118-5A229  74	5191001018	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.01903	-118.19251	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47185	12041-20000-10667	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin # 1610 CS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47186	17041-10000-08177	10250 W SANTA MONICA BLVD # FC-04	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PLAN CHECK FOR  ""CHICK-FILL-A""  IN WESTFIELD CENTURY CITY. SUITE FC-04. SERVICE TO THIS TENANT IS EXISTING."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47187	16041-20000-12186	416 W 8TH ST Basement-1st Floor	90014	14	127-5A209  58	5144018030	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.04471	-118.25646	Plan check for power only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement of the kitchens in the basement, ground floor, mezzanine, and roof.  Note: Building application has been created under 15016-10000-28551	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47188	17041-20000-28028	12263 N LIMA WAY	91342	7	219B149   936	2611046028		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.29408	-118.4562	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47189	16041-10000-27474	447 S HEWITT ST	90013	14	127-5A215 356	5163022017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.04216	-118.23526	Title 24 plan check only.  Total area = 4,456 sq. ft.  Two new panels with associated lighting and receptacle loads.  CHANGE OF USE FROM ARTIST IN RESIDENCE TO OFFICE ON THE SECOND FLOOR AND A SMALL SPACE ON THE GROUND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47190	10041-10000-19993	629 S JUNE ST	90005	4	135B185   445	5507017007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	10/25/2010 12:00:00 AM	ADDRESS	34.064	-118.33481	New 600 Amp service. Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47191	14041-20001-12041	12655 W SANDHILL LANE UNIT 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/06/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.97753	-118.41457	((EXPEDITE FEES))pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #2. 2/3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47192	17041-20001-26135	201 S RIMPAU BLVD	90004	4	135B185    80	5515008038	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.06934	-118.33094	Expedited plan check fee per applicant request.  PV1.  Install 9.27 kW CEC AC rated PV system, interconnect to 400 A 120/240V main service panel.  (32) modules with Enphase IQ6PLUS-72-2-US microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47193	13041-10000-08051	706 E DUCOMMUN ST	90012	14	130-5A217 264	5173016005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Info Complete	04/25/2013 12:00:00 AM	ADDRESS	34.05183	-118.23298	CHANGE SWITCHBOARD WITH ONE METER TO THREE METER SWITCH BOARD FOR COMMERCIAL WAREHOUSE BUILDING. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47194	19041-20000-14603	23455 W CALIFA ST	91367	3	177B093   846	2041003008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.17747	-118.63805	Plan checkf for PV roof mounted system, PV system size: 13.72KW DC, 11.4KW AC with 45 PV Modules and 1 inverter(11.4KW)Fees $65.01 due to California Senate Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47195	17041-10000-41553	5151 W ROMAINE ST	90029	13	144B193  1410	5537020039	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Apartment			11/17/2017 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.08864	-118.30414	PC FOR POWER AND ENERGY FOR A  NEW 4-story apartment with attached parking structure, with residential amenities over (1) level subterranean garage (76 affordable -  low- income seniors restricted units).SCOPE INCLUDES NEW SERVICE 2000A 120/208VCIRCUITS, PANELS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 9833 SQ.FT. B# 13010-10000-01894	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47196	17041-10002-00941	2023 S UNION AVE	90007	1	124-5A201  60	5124002021	[Q]C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Approved	07/07/2017 12:00:00 AM	ADDRESS	34.03665	-118.28252	changes to approved set of plans - scope includes addition of lighting and modification of formsoriginal permit under 17041-10000-00941Energy plan check for (2) new office in the first floor and new outlets on second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47197	14041-10000-17169	1602 N ELEVADO ST	90026	13	144A205   434	5425005019	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.08719	-118.27326	PV1, INSTALL 10.965 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OTIMIZERS.(43) MODULES: TRINA SOLAR TSM255PA05.18(2) TRANSFORMERLESS INVERTERS: SOLAREDGE SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47198	12041-10000-06574	14006 W RIVERSIDE DR #0245	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	REMODELING OF RETAIL STORE PINK VICTORIA'S SECRET AT THE WESTFIELD FASHION CENTER. NEW LIGHTING AND CIRCUITSPLAN CHK IS FORT TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47199	15041-10000-02307	724 W 48TH ST	90037	9	111A201    84	5018024009	RD1.5-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	33.99953	-118.28643	PV1.  Install 5.23 kW DC roof-mounted, utility-interactive PV system.  (1) Central inverter and (16) modules on a  standard plan.  Note. applicant was advised for online service, but still insisted to do plan check over the counter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47200	19041-10000-44479	7457 N DEERING AVE	91303	3	186B105   365	2111030004	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	34.20654	-118.59677	REPLACE FLOURESCENT TROFFERS WITH NEW LED RETROFITS KITS OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47201	14041-10000-24376	5160 N VINELAND AVE 101B	91601	2	171B173  1378	2419001042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.16418	-118.37009	Tenant improvement in a pet retail storeplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47202	13041-10000-32513	7755 W SUNSET BLVD 200-203	90046	4	147B177   985	5551021020	[Q]C1-1XL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.09823	-118.35855	T24 ENERGY ONLY. OFFICE SPACE ON  2ND FLOOR . 625SQFT. 2ND FLOOR. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47203	11041-10000-23626	8930 N VILLAGE AVE	91352	7	195B177   265	2404001006	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley	YES	1021.07	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	34.23076	-118.35614	Weight room for a private school.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47204	15041-20001-16306	936 S OLIVE ST UNIT 352	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #13 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47205	12041-20001-10692	5525 N ETIWANDA AVE	91356	3	174B125   518	2160011026	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.17048	-118.53094	Medical office TI. 5 new branch circuits. Plan check for energy. Plan check for power on 12041-20000-10692.  1754 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47206	19041-10000-25949	2215 S WESTWOOD BLVD D	90064	5	126B157   457	4322002025	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM			Corrections Issued	07/08/2019 12:00:00 AM	ADDRESS	34.04321	-118.43144	ENERGY PC ONLY FOR TI TO AN (E) RESTAURANT. AREA OF SCOPE 1560SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47207	19041-20000-04486	10200 W VENICE BLVD 109A	90232	5	120B165  1428	4208004033	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.02122	-118.40202	Plan check for Medical dental office change of use from retail to dentist office space # 109A. Total area: 1063 sq ft. 18016-10000-37471	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47208	16041-20000-17847	1974 N AVON ST	90026	13	144A211   370	5415009016	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.08703	-118.2482	Plan check for PV roof  mounted system. Sysem size:4.5 kW with 14 AC modules. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47209	10041-10000-18995	8631 W 3RD ST # 1040 E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	11/19/2010 12:00:00 AM	ADDRESS	34.07373	-118.38036	T-24 and emergency lighting plan check.  Suite 1040E	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47210	18041-10001-11405	1837 N MANDEVILLE CANYON ROAD	90049	11	135B137   223	4426007012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM			PC Approved	04/04/2019 12:00:00 AM	ADDRESS	34.06782	-118.4942	SUPPLEMENTAL CHANGES TO APPROVED SET CHANGING THE LOCATION OF EQUIPMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47211	18041-10001-24937	3801 S BROADWAY PL	90037	9	117A203   240	5122039036	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	11/02/2020 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.0136	-118.27616	Change to approved set by adding new ckts on the floor plan. All changes under delta-3 only.(((NEW WAREHOUSE. 600 AMP SERVICE. 49,796 SQR FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47212	18041-30000-11422	12820 W PANAMA ST	90066	11	105B157   395	4223008012	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	33.98477	-118.42659	Plan check for Title 24 only in existing space, new general lighting in the area under T.I. Total area: 13,140 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47213	18041-20000-47391	1710 S CARMELINA AVE pv1	90025	15	123B145   216	4259009003	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.03511	-118.46171	pv1install roof mounted pv system sized 4.1KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47214	14041-10001-34485	850 W WASHINGTON BLVD	90007	1	124-5A203  64	5124020022	[Q]C2-2-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM			PC Approved	02/23/2015 12:00:00 AM	PIN	34.0363201	-118.27708332	Expedited plan check per applicant request.  PV2.  Install 23.1 kW DC utility-interactive, rooftop-mounted PV system.  Transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47215	17041-10000-39474	701 S HILL ST	90014	14	129A209   229	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	01/14/2022 12:00:00 AM	ADDRESS	34.04582	-118.25475	FULL PLAN CHECK FOR AN EXISTING 17 STORIES OFFICE BUILDING CONVERTED TO MIXED USED - 125 APTS & RETAIL WITH A NEW 3000-AMP SERVICE 3-PHASE 480/277V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47216	16041-10000-16670	1927 S VIRGINIA ROAD	90016	10	126B185  1074	5061005004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Expired	06/14/2018 12:00:00 AM	ADDRESS	34.03903	-118.33589	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING 23 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47217	14041-20000-16839	11239 W VENTURA BLVD 214 & 215	91604	2	162B173  1248	2366035036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.14181	-118.37523	Per applicant requested, plans submitted for power and energy plan check.  T.I. to combine two retail spaces and convert to 26' x 55' irreg. shaped dance studio.  Install branch circuits and general/emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47218	17041-20000-32567	2216 N MEADOW VALLEY TER	90039	4	148-5A205 328	5432031008	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Expired	05/02/2024 12:00:00 AM	ADDRESS	34.1005	-118.27157	Install 13.5 kWh energy storage system.  (E) solar reconnected to new subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47219	11041-10000-16442	11801 W PICO BLVD	90064	11	123B149   813	4259038001	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	09/30/2011 12:00:00 AM		Permit Finaled	12/21/2011 12:00:00 AM	ADDRESS	34.03064	-118.44807	T.I.  2 existing store front.  One is being demolished to make room for a parking lot, and the other is being taken all the way to stubs and converted to a private school.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47220	15041-20000-21938	8034 N LANKERSHIM BLVD	91605	6	189B169   150	2311005017	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.21667	-118.38758	Plan check for power and energy for core and shell manufacture facility. 800A service new switch gear and panels. Total indoor and outdoor area: 10,908sqft and 8,881sqft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47221	18041-20000-18032	20740 W SPRUCE CIR (#79)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.29484	-118.58602	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47222	15041-20000-16127	7045 N BOTHWELL ROAD	91335	3	183B117   335	2130002008	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.19872	-118.56135	Plan check for PV roof mounted system. System size: 5.0kW with 18 modules and 1 inverter (5.0kW). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47223	15041-10000-04141	11149 N GLENOAKS BLVD	91331	7	210B161   340	2536007005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.27257	-118.41076	Plan check for PV 1 roof mounted system, system size 6.8kW with 10 modules and 2 inverters. Note: Plan check over the counter due to online payment issues and service restricts payment process.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47224	16041-20001-31357	1443 N DEVLIN DR	90069	4	147B169   938	5560001028	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.09572	-118.38735	Revisions to approved set of plans.  Plans updated to reflect existing site conditions with regard to locations of (E) equipment.  $0 plan check fee due to State Senate Bill SB 1222. (((Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (46) modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47225	12041-10000-27018	3914 W WILSHIRE BLVD	90010	10	132B193    79	5092030037	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Approved	11/09/2012 12:00:00 AM	ADDRESS	34.06153	-118.31173	Existing restaurant remodeling. Plan Check for Title 24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47226	14041-20001-20236	8120 N JASON AVE	91304	12	189B093    48	2020021014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	34.21782	-118.63511	Expedited plan check fees.PV1.  Install 11.98 kW roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47227	16041-10000-14332	11895 N WHEELER AVE	91342	7	216B165    52	2531033020	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.28661	-118.39877	PV1, INSTALL 5.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MICRO INVERTERS: ENPHASE M215-60-2LL(20) MODULES: CANADIAN SOLAR CS6P-260PSTANDARD PLAN IS USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47228	10041-10000-00536	505 S BONNIE BRAE ST 1-53	90057	1	133-5A205 267	5154026003	[T][Q]R4-1	Central	Westlake		YES	2089.03	Electrical	Electrical	Public Safety Only			01/12/2010 12:00:00 AM	01/12/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.05924	-118.27229	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47229	16041-20000-08152	4305 N LAUREL CANYON BLVD	91604	2	165B165   645	2367004045	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			03/08/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.14888	-118.39665	Plan check for a fire alarm for a 4-story apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (51) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47230	17041-10000-20742	13546 W DESMOND ST	91331	7	210B157    87	2523005006	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.27517	-118.42768	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47231	18041-10000-03393	1339 W VENICE BLVD	90006	1	127-5A201 198	5135008022	CM-1	Central	Westlake	Pico Union		2243.10	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.04346	-118.28302	PC for T24 only for replacing existing fixtures with LED fixtures. Total area 2900sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47232	15041-20001-10236	19119 W VICTORY BLVD BLDG 10	91335	3	180B121   530	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM			PC Approved	04/29/2015 12:00:00 AM	ADDRESS	34.18675	-118.54997	EXPEDITED PER APPLICANTS REQUESTPV2. APARTMENT BUILDING. ( TWO MIRRORED BUILIDING ONE ADDRESS) (2 OF 2) BUILDING 10 , SYSTEM SIZE: 9.75 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47233	14041-10000-02558	1001 N VERMONT AVE	90029	13	144B197   961	5538022021	[Q]C2-2D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			01/29/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.08964	-118.29193	PLAN CHECK FOR POWER AND ENERGY. TI FOR MARKET ON FIRST FLOOR AND RESTAURANT ON SECOND FLOOR. UPGRADING EXISTING SERVICE WITH NEW 800A, 120/240V, 3PH, 4WIRE UNDERGROUND SERVICE. NOT LOCATED IN METHANE ZONE. PROJECTED AREA IN LIGHTING WORK IS APPROX. 13538 SQ FT ( 8118 INDOOR, 5420 OUTDOOR) . NOTE: THIS PLAN WILL BE SUBJECTED TO 2011 NEC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47234	16041-10000-36272	2100 W SUNSET BLVD	90026	13	139-5A207 103	5402035001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.07739	-118.26381	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTUARANT. SCOPE INCLUDES NEW PANEL, NEW LIGHTS AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 1525 SQ. FT. B#16016-10000-07033	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47235	14041-10000-17066	15610 W MOORPARK ST UNIT 7	91436	5	168B141   602	2261029***	R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Apartment			06/26/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	PIN	34.1559257	-118.47396414	PV1, INSTALL 8.925 KW DC ROOF-MOUNTED SOLAR ARRAY ON A PARTMENT BUILDI NG, INTERCONNECT WITH MAIN SERVICE PANEL.(2) INVERTERS: SOLAREDGE SE3000A-US-ZB-U AND SE5000A-US-ZB-U(35) MODULES:TRINA SOLAR TSM-255PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47236	15041-20000-38541	20925 W FRANCINE LANE	91311	12	207B109   696	2706017040	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.26251	-118.58972	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel.(28) Kyocera KU265 Modules(1) Fronius Primo 7.6-1 Inverters(1) combiner box	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47237	12041-20000-17049	145 S FAIRFAX AVE	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM			PC Approved	07/23/2012 12:00:00 AM	PIN	34.07292853	-118.36175524	T-24 lighting plan check for ground floor elevator lobby remodel.  Existing permit 12041-90000-17007.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47238	13041-10000-28562	6255 W SUNSET BLVD 11TH FLOOR	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	TITLE 24 ENERGY PLAN CHECK ONLY. HIGH RISE. OFFICES. CHANGES TO COMMON AREAS. 11TH FLOOR. OTHER FLOORS ARE ALSO BEING DONE ON DIFFERENT APPLICATIONS #'S. 1435 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47239	10041-10000-04287	21747 W ERWIN ST	91367	3	177B105   124	2146029017	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM			Corrections Issued	04/13/2010 12:00:00 AM	ADDRESS	34.18325	-118.60307	Change of use to A3 occupancy for ballet classroom.  T.I. for existing building.  Plan check for power and energy. TO COORDINATE WITH 10041- 2000-04678	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47240	14041-20001-18405	13237 N GLADSTONE AVE	91342	7	225B157   672	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM			PC Approved	01/08/2015 12:00:00 AM	ADDRESS	34.31154	-118.42954	revisions to an approved set of plans.  energy corrections per inspectors instructions.  revising circuits, controls, and adding demend response.  Plan check for power and energy. Change Rite Aide retail store into a 99cents retail store. Existing service to remain. All other equipment is new, including panels and air conditioning units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47241	10041-10001-23576	10250 W SANTA MONICA BLVD #480	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM			Reviewed by Supervisor	05/11/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	NEW BJ RESTAURANT AT THE CENTURY CITY MALL  <<<<<<<<<<<<<<<<MODIFICATION TO APPROVED SET OF PLANS>>>>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47242	13041-10000-01857	701 E 59TH ST	90001	9	105B205    23	6007002017	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Expired	02/18/2015 12:00:00 AM	ADDRESS	33.98729	-118.26307	Install fire alarm to monitor sprinkler system for single story warehouse building. This fire alarm system installation is only for the office area. 5 devices and 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47243	14041-10000-17565	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	33.95667	-118.4165	"PLANCHECK FOR POWER AND ENERGY. INSTALLTION OF A NEW WORKSHOP BUILDING IN A N EXISTING ART AND DESIGN COLLEGE. VARIANCE HAS BEEN SUBMITTED FOR THE INSTALLATION OF A CUSTOM BUILT DISTIRBUTION BOARD MSC.BUILDING P: 14010-10000-01887 : CONSTRUCTION OF A NEW  66' X 79'  ""SHOP"" BUILDING FOR THE OTIS COLLEGE OF ART & DESIGN"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47244	19041-20000-32062	20810 W ACORN CIR UNIT #235	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.29427	-118.58702	PV1.  Install 3.15 kW roof mounted PV system.  (9) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47245	18041-10000-21550	1047 S WINDSOR BLVD	90019	10	132B189  1130	5082019021	R1-1-HPOZ	Central	Wilshire	Olympic Park		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.05437	-118.32621	Install new PV1 rooftop solar system 7.6 kW AC (25) modules, (1) inverter. System includes (1) ESS under separate application#	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47246	14041-10000-22686	4640 W HOLLYWOOD BLVD	90027	13	147B197 457	5542014007	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.10006	-118.29052	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. NOT A PATIENT CARE AREA PER APPLICANT. 2050 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47247	16041-30000-18171	13631 W TERRA BELLA ST	91331	6	201B157   163	2645007006	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.2499	-118.43016	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (21) modules, (2) combiner boxes, (2) inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47248	14041-20001-15811	2479 N LANTERMAN TER	90039	4	150A205   319	5432011014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.10413	-118.27037	PV1.  Install 7.66 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47249	14041-20000-10912	10250 W CONSTELLATION BLVD 10TH FLOOR	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	PLAN CHECK FOR T24 ENERGY. TI HIGH RISE 10TH FLOOR CORRIDOR ONLY.SQFT 1608, EMERGENCY LIGHTING. NO CHANGE IN OCCUPANCY AND NEWLY CONNECTED LOAD < 400AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47250	15041-10000-17008	1502 E OPP ST	90744	15	033B213   666	7425040009	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			PC Approved	06/03/2015 12:00:00 AM	ADDRESS	33.78372	-118.24473	CONSTRUCTION  OF NEW MEZZANINE AND OFFICE IN (E) WAREHOUSE,PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47251	16041-10000-18508	2789 W OLYMPIC BLVD 101-301	90006	10	129B197   186	5078007030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.0529	-118.29436	PC FOR POWER AND ENERGY. 3-STORY COMMERCIAL BUILDING. TOTAL AREA 16710 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47252	16041-10001-17475	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	10/24/2016 12:00:00 AM	ADDRESS	33.95667	-118.4165	EXPEDITE FEE. ----VOID CUSTOMER WITHDREW EXPEDITE. PC REGULAR ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47253	13041-20000-20538	17527 W ARMINTA ST	91325	12	189B129   665	2201030020	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.21431	-118.51508	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 5.184 KW. 24 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47254	13041-20000-05686	21155 W CALIFA ST	91367	3	177B105   104	2149002026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.17716	-118.59277	Change to lighting in an existing single-story office building.  Load is less than 400 amps per applicant.  Plan check is only for Energy, with Emergency lighting.  Permit is under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47255	15041-10000-31565	8500 W BEVERLY BLVD STE 623	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	T-24, TI TO A RETAIL TENANT INSIDE THE BEVERLY CENTER. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1494.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47256	16041-20000-24631	10730 N MEMORY PARK AVE UNIT B	91345	7	207B145   239	2649003028	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.26537	-118.46322	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED TO MSP FOR UNIT B.SOLAR CLEARANCE FOR THIS APPLICATION SHALL ACCOUNT FOR UNITS A-E UNDER THIS ADDRESS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47257	17041-10001-08936	6600 N TOPANGA CANYON BLVD SUITE 2092	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Changes to approved set.  Revised lighting layout and Title 24.  Inverter system used and exit signs changed to dual circuit.  Updated equipment schedule and power plan layout.  Panelboard loads reorganized and elevation drawings changed. All changes clouded under deta 4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47258	17041-10000-32526	16945 W SHERMAN WAY	91406	6	183B133    24	2227003054	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Issued	09/12/2017 12:00:00 AM	ADDRESS	34.20137	-118.50233	Remove HID fixtures and replace with new LED fixture  - Title 24 only. Total affected area 22000sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47259	14041-20002-03328	7722 N RESEDA BLVD	91335	12	189B125   819	2102021039	R3-1, RD5-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.21126	-118.53586	((((($0 plan check fee due to senate bill 1222 from 2012))))))change in system design. changes include: 1 less inverter, point of interconnection to 1 phase service, deduction in number of modules, new roof layout. new system size is now 42.8kw ac. total number of modules is now 160.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47260	17041-10000-20003	425 E ROSE AVE	90291	11	111B141   400	4240007008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	33.99806	-118.47436	PC FOR RESTAURANT TI. PC FOR POWER AND ENERGY. NEW 600A 120/240V SINGLE PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD.  A OCC LOAD > 100. TOTAL AFFECTED AREA IS 2766 SQ. FT.         BUILDING PERMIT 17016-10000-09808	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47261	14041-20000-03981	13909 W FOOTHILL BLVD	91342	7	225B153   331	2509002006	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Closed	01/29/2015 12:00:00 AM	ADDRESS	34.31239	-118.43634	PLAN CHECK FOR POWER AND ENERGY FOR OUTDOOR SOCCER FIELD. NEW 600A 120/240, 3PH, 4W SERVICE. INDOOR LIGHTING FOR 2 RESTROOMS, AND HARDSCAPE SCONCES LIGHTING FOR OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47262	15041-10000-21695	5971 W VENICE BLVD 1st Floor	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.03865	-118.37272	Energy plan check for a medical office T.I located in the 1st floor of  a 4-story commercial building;  Scope is for control receptacles in the front desk area only, No lighting involved.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47263	18041-20000-34710	14078 W HOYT ST	91331	6	201B153    49	2645021040	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.2515	-118.43998	Plan check for PV roof mounted system, system size: 6.0kW with 21 modules and 1 inverter connected to center feed.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47264	15041-20000-38832	15800 W ROSCOE BLVD	91406	6	192B141   492	2673021041	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.2212	-118.47638	$0 permit fee due to State Senate Bill SB-1222.  Plan check for PV roof mounted system. System size: 1,109kW(1MegaW) with 3,580 modules (Canadian Solar Max Power CS6X-31OP) and 24 inverters (CHINT CPS SCA36KTL-DO/US) connected to  new 1,600A switch gear.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47265	11041-20000-24310	4700 S LINCOLN BLVD	90292	11	105B153   151	4224014019	C4-1, P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	33.9803	-118.43846	T.I.  Restaurant remodel.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47266	14041-20000-22693	10447 N OKLAHOMA AVE	91311	12	207B109   629	2706015024	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.26046	-118.58664	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5.59kW.(26) EnPhase M215-IG microinverters(26) Hyundai HiS-M250MG pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47267	13041-20000-29716	15651 W RAYEN ST	91343	12	195B141   333	2672009034	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.23203	-118.47366	FOPV1 12.99KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-5000-OUTD-US and PVI-6000-OUTD-US] [( 53) MOD: yingli {YL245-29b}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47268	18041-10000-36452	933 S WESTERN AVE	90006	4	132B193  1013	5093001039	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2126.20	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.05487	-118.30929	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47269	12041-10000-09644	18782 W FAIRFIELD ROAD	91326	12	207B121   678	2728031032	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Expired	05/22/2014 12:00:00 AM	ADDRESS	34.26173	-118.54242	Plan check for 9.36KW roof mounted photovoltaic system single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47270	14041-10000-23503	445 S FIGUEROA ST SUIT #3210	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	HIGH RISE, TI. WE DOING LIGHT AND TITLE 24 ENERGY CAL THIS ALSO INCLUDING EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47271	17041-20000-37267	14647 W MORRISON ST	91403	4	169-5A149  36	2263027001	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.16043	-118.45252	addition of (1) tesla powerwall.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47272	17041-20000-46066	317 W PACIFIC COAST HWY #B	90744	15	036B205   998	7421024014	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	33.79117	-118.26668	Commercial retail TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47273	11041-10000-22888	10100 W GALAXY WAY	90067	5	132B161   690	4329007***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM			Corrections Issued	10/25/2011 12:00:00 AM	ADDRESS	34.05582	-118.41064	T.I. to the employee restroom of an existing commercial space.   PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47274	11041-20000-10098	11511 N HERRICK AVE	91331	7	213B157   558	2523014900	(T)R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM	05/19/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.27919	-118.42351	Recheck for NEC2008. New installation 53.8 KW roof top Photovoltaic System at charter school.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47275	19041-10001-00583	2113 N MOUNT OLYMPUS DR	90046	4	151-5A175  29	5569026009	RE40-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.11092	-118.36751	**expedite per applicant request**NEW GROUND MOUNT SOLAR SYSTEM CONSIST OF 64 MODULES (PANASONIC N330) , 64 OPTIMIZER (SE P400) AND 2 CENTRAL INVERTERS (SE11400A-US & SE7600H-US).  SYSTEM SIZE IS 21.12KWdc and 19KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47276	13041-10000-32393	2406 N PESQUERA DR	90049	11	141B133   363	4492020040	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.07884	-118.50823	PV1, Install 10.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 41 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47277	16041-10000-13658	7511 N PONCE AVE	91307	12	186B097   393	2022008018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Expired	05/21/2018 12:00:00 AM	ADDRESS	34.2069	-118.62227	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.46KWdc / 8.8KWac.(32)MODULES-SUNPOWER SPR-327NE-WHJT-D(2)INVERTERS-SMA 5000TL-US-22 & SMA 3800TL-US-22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47278	11041-10000-10581	10351 W SANTA MONICA BLVD	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM	06/06/2011 12:00:00 AM		Permit Finaled	08/12/2011 12:00:00 AM	PIN	34.0585564	-118.42324002	T24 and emergency lighting for remodeled restaurant.   T.I. TO EXIST. RESTAURANT.  EXPAND PATIO AREAS.  REDESIGN DINING AREAS, ADD RESTROOMS. NO CHANGE IN PARKING. LIMIT HOURS OF OPRERATION FROMM 7:00 AM TO 11:00 PM. SALES AND CONSUMPTION OF ALCOHOL IS NOT PERMITTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47279	15041-10000-36002	5051 W RODEO ROAD	90016	10	120B177  1408	5046013006	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.02173	-118.35358	T-24, CHANGE OF USE FROM OFFICE SPACE TO RETAIL IN AN (E) BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3761***INSPECTION FEEES WERE PAID UNDER EXPRESS PERMIT #'S:15041-10000-13749 AND 15041-10002-13749	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47280	18041-20000-21254	3831 S HUGHES AVE #608	90232	5	120B165  1276	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.02242	-118.39823	Plan check for power and energy. Project site is an existing suite in a commercial building. Project scope is a tenant improvement to a dental office. Total lighting area = 1,460 sq. ft.Note: Building application has been generated under 18016-20000-16956.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47281	15041-10008-06920	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.06326	-118.20213	PC FOR DELTA V CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47282	14041-20000-26057	7300 N QUARTZ AVE	91306	3	186B117   871	2115009006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.20297	-118.56434	PV1Central transformerless inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7kW.(1) SMA Sunny Boy SB7000TL-US-12 transformerless inverter(24) SunPower SPR-327NE-WHT-D pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47283	11041-20001-23370	6500 W WILSHIRE BLVD 23rd floor	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/03/2012 12:00:00 AM	ADDRESS	34.06371	-118.3703	CHanges to original plan. Removed offices from scope of work. 23rd floor. 1080 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47284	14041-20000-27345	6303 N OWENSMOUTH AVE 2nd floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI to (E) commercial office space in existing commercial highrise building.  Plan check for Title 24 Part 6 for lighting alteration.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47285	17041-20001-14962	110 E 9TH ST 12TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.04107	-118.25479	6.1.2017 - Plan check for modifications to approved set. Changing lighting fixtures in a corridor. Update lighting fixture schedule and T24 documents to reflect changes. Changes clouded delta 3. =====PLAN CHECK FOR POWER AND ENERGY 2016. TENANT IMPROVEMENT FOR OFFICES (IGNIGHTED SPACES) ON 12TH FLOOR EXISTING HIGH RISE. RELOCATE EXISTING TRANSFORMERS AND PANELS.  PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-20000-20001.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47286	13041-20001-11113	4082 S LINCOLN BLVD	90292	11	108B149  1565	4230002012	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/08/2013 12:00:00 AM	ADDRESS	33.98861	-118.44578	(((SUPP. ANOTHER CHANGE IN FIXTURE TYPE A. CHARGE ANOTHER PC HOUR. NO PERMIT TO BE ISSUED. PC ONLY, T24 ENERGY COMPLIANCE. )))TI TO EXISTING RETAIL SPACE. TOTAL AREA 4038 SQ FT. CHANGE OUT OF FIXTURES TO MORE ENERGY EFFICIENT FIXTURES. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47287	17041-20001-30775	8232 W JAYSEEL ST	91040	7	208-5A193 335	2555016015	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM			PC Approved	09/06/2017 12:00:00 AM	ADDRESS	34.2654	-118.31271	Expedited plan check fee.  PV1.  Install 5.5 kW roof mounted grid tied PV system, centerfed interconnection.  (19) modules with (1) 4.6kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47288	19041-20000-11871	5717 W CARLTON WAY	90028	13	148-5A191 190	5586035013	R4-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			04/02/2019 12:00:00 AM	06/14/2021 12:00:00 AM		Issued	06/14/2021 12:00:00 AM	ADDRESS	34.10061	-118.31425	Plan check for power and energy. Project site is a 7 story, 39 unit apartment building. Work includes a 1,200 amp service and a total lighting area of 20,209 sq. ft.Note: Building application has been generated under 18010-10000-05385	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47289	19041-20000-30081	14852 W VANOWEN ST	91405	6	180B149    49	2236001022	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.19371	-118.45695	T24 PLAN CHECK FOR INDOOR/OUTDOOR LIGHTING FOR EXISTING COMMERCIAL BUILDING IN A NON-CLASSIFIED AREA. LIGHTING AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE  = 3,620 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47290	13041-20000-09174	2018-2020 1/2 E CESAR E CHAVEZ AVE	90033	14	129A223   128	5183001020	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.04854	-118.21218	Plan check for energy and emergency lighting. Single story commercial building. Esquezani.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47291	15041-10004-36116	7326 N VANALDEN AVE	91335	3	186B121   819	2104026001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.20382	-118.54902	Revision to approved set under Delta-1: relocate 4 modules, all other remain the same. Permit under 15041-10000-36116. Zero fees due per California Senate Bill 1222.<<PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE: 9KW. (29) MODLUES AND (3) INVERTERS. (29) SUNPOWER SPR-327-NE-WHT-D(3) SMA AMERICA SB3000TL-US-22>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47292	12041-20000-20127	11855 N HIGHWATER ROAD	91344	12	216B129   273	2601065001	A1-1-O-K, RA-1-K, RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.28662	-118.51851	New 7.4kw rooftop photovoltaic system for an existing single family residence.  System is ungrounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47293	15041-10000-29330	300 S GRAND AVE #LP150	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Full PC for power and energy for a commercial bldg (restaurant/eat-carry out). NOTE TO PLAN CHECKER: FOR T-24, PERFORMANCE FORMS WERE USED INSTEAD OF PRESCRIPTIVE METHOD. sqft = 3088	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47294	13041-10000-00271	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Apartment			01/04/2013 12:00:00 AM	05/06/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.04403	-118.2199	replacement of an existing fire alarm system. building is a retirement home.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47295	16041-30001-23849	744 N TOYOPA DR	90272	11	126B129   439	4411007020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2016 12:00:00 AM			PC Approved	07/20/2016 12:00:00 AM	ADDRESS	34.04203	-118.52051	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (367) PV roofing shingles (1,635 sq. ft.), and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47296	11041-10000-17469	1631 N ECHO PARK AVE 1-5-bldg  6	90026	13	142-5A209 351	5419008036	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			08/17/2011 12:00:00 AM	03/23/2012 12:00:00 AM		Issued	03/23/2012 12:00:00 AM	ADDRESS	34.08274	-118.25473	NEW 5-UNIT APARTMENT BUILDING (BLDG 6).  PLAN CHECK FOR ENERGY AND POWER.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47297	14041-10001-06547	110 N GEORGE BURNS ROAD	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM			PC Approved	08/21/2014 12:00:00 AM	ADDRESS	34.07564	-118.38149	((8/21/2014 - Supp. app. for changes to approved set plan check at request of inspector.  Reorganization of panelboard circuites and change of breaker type))Master permit work description: TI in an existing lab for Cedars Sanai Medical center. Full plan check per applicant request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47298	19041-20000-36648	5249 E REMSTOY DR	90032	14	147A237   155	5309009044	R1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.0974	-118.16554	PLAN CHECK FOR NEW ROOFTOP PVSYSTEM ON EXISTING SFD. SYSTEM SIZE IS 3.78 KW DC/3.8 KW AC. SCOPE OF WORK CONSISTS OF (12) PV MODULES WITH OTPIMIZERS AND A 3.8 KW INVERTER,	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47299	18041-10000-48616	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/24/2018 12:00:00 AM			Verifications in Progress	03/05/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	Replacing two existing 500HP Fire Pumps with one new 400HP Fire Pump connected to normal power in a high rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47300	16041-20000-06784	13309 W WOODBRIDGE ST	91423	4	165B157   596	2360011***	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Apartment			02/26/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.14771	-118.42307	PV2. ROOFMOUNTED SOLAR SYSTEM FOR APARTMENT. SYSTEM SIZEl 15.6 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47301	19041-20000-32162	5250 N LANKERSHIM BLVD	91601	2	171B173  1421	2350018090	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	05/03/2020 12:00:00 AM	ADDRESS	34.16668	-118.37545	TI ON FLOORS 2 AND 3  OF 9 STORY BUILDING, WORK INCLUDES NO NEW PANELS, ONLY NEW LOADS AND T24. TOTAL SQUARE FOOTAGE = 39400SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47302	17041-10000-44607	15223 W LASSEN ST	91345	7	201B145   183	2660011011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.25016	-118.46394	PC FOR ROOF MOUNTED PV ON SFD.SYSTEM SIZE 6.08KWDC/ 5.0KWACSCOPE INCLUDES 19 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47303	16041-10000-22643	7760 N YARMOUTH AVE	91335	12	189B129  1072	2120001014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.21178	-118.51953	PV1,  NEW  12.426 KWDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE INTERCONNECTING THROUGH A LOAD CENTER AND MAIN SERVICE PANEL.(38) MODULES:  SUNPOWER SPR327NE-WHT(2) INVERTERS: SMA SB7700TL-US-22 AND SB3800	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47304	16041-10000-13760	10219 N CANOGA AVE	91311	12	204B105   421	2747010021	[T][Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.25589	-118.59748	PC for energy only. Remove HID fixtures and replace with new LED fixtures. Total sq ft = 4436	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47305	12041-10001-13993	8847 W VENICE BLVD	90034	10	123B169  1238	4312008045	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	08/15/2013 12:00:00 AM	ADDRESS	34.03063	-118.38653	DELTA 1 CHANGES TO PERMITTED SET OF PLANS- CHANGES ARE CLOUDED ON  PARTICULAR PAGES(((((((((Change of use to office.  New 800A service and switchboard.  Plan check for power and energy. Existing 2 story commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47306	17041-10001-32350	3525 W 8TH ST	90005	10	132B193   572	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			07/31/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.05782	-118.30714	"DELTA ""F"" CHANGES TO THE APPROVED PLANS FOR 7 ADDITIONAL CEILING SENSORS FOR A TOTAL OF 26 DEVICES. PLAN CHECK ONLY. PERMIT WILL BE ISSUED UNDER 17041-10000-32350<<<<METHANE DETECTION SYSTEM FOR METHANE LEVEL 5 ON (E) COMMERCIAL BUILDING>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47307	15041-10001-08256	8635 N ROBERT AVE	91352	6	192B173    89	2408018001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM			PC Approved	05/05/2015 12:00:00 AM	ADDRESS	34.22615	-118.3717	((EXPEDITE FEES))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC. 17 MODULES AND 1 INVERTER. SUBMITTED PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47308	19041-10000-21754	470 E BAUCHET ST	90012	14	133-5A217  56	5409018920	PF-1XL-RIO	Central	Central City North			2060.20	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM			PC Info Complete	07/26/2019 12:00:00 AM	ADDRESS	34.05765	-118.22942	T-24 PLAN CHECK FOR A TI TO REPURPOSE EXISTING EMPLOYEE BREAKROOM AREA AT AN EXISTING BUS MAINTANEANCE FACILITY FOR ACCESSORY FOOD SERVICES (EMPLOEES ONLY CAFETERIA). SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 2536 SQ.FTB# 19016-10000-09054	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47309	17041-10000-33868	3214 W 75TH ST	90043	8	102B185  1182	4012013010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Expired	09/17/2023 12:00:00 AM	ADDRESS	33.97169	-118.32924	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222. ((((((PV SYSTEM WITH BATTERY STORAGE. USING 3.8KW AC SYSTEM WITH 13 MODULES AND 5.8KW STORAGE UNIT WITH 13.5KWH OF STORAGE. NEW COMBINER PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47310	11041-10000-24683	5450 W PICO BLVD	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.04862	-118.35714	Fire alarm system for a new commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47311	18041-20000-24403	17312 W SUPERIOR ST	91325	12	201B133   435	2755008005	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.24655	-118.51197	pv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47312	14041-10000-14144	1501 N SOTO ST	90033	14	133-5A227   7	5202002019	[Q]C2-1	East Los Angeles	Northeast Los Angeles			2033.00	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.06079	-118.19919	SURFACE PARKING LOT  (317 PARKING SPACES)TITLE 24 PLAN CHECK FOR POLE SUPPORTED LUMINAIRES IN  NEW PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47313	16041-10000-23839	7855 N LEMP AVE	91605	6	189B169   500	2311013015	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Expired	08/14/2018 12:00:00 AM	ADDRESS	34.21357	-118.38464	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.98KWdc / 4.945KWac. STANDARD PLAN IS BEING USED.(23)MODULES-HYUNDAI HiS-S260RG(23)MICROINVERTERS-ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47314	16041-20000-29385	23508 W CANZONET ST	91367	3	171B093   362	2044019011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.16573	-118.63889	PV1INSTALL ROOF MOUNTED PPV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47315	17041-10000-27847	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC for T24 only for new lights and receptacles in airport ticketing counter. All work clouded under delta 1. Installing one new panel, new circuits and equipment. Load under 400A. Building #17016-10000-08505	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47316	17041-10000-04305	1830 N GLENDALE BLVD	90026	13	144A209   193	5423004001	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			02/13/2017 12:00:00 AM			Reviewed by Supervisor	02/23/2017 12:00:00 AM	ADDRESS	34.08863	-118.25922	Plan check for New 18 units Single family residence. 1600A Service.B#16020-10000-03941	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47317	18041-20000-47169	12400 N WOODLEY AVE	91344	12	219B137    79	2605005010	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.29607	-118.49338	Plan check for a PV1 roof-mounted PV system. System size is 7.15 kWdc/7.6 kWac and consists of (1) inverter, (22) modules, (1) load center, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47318	19041-10000-51230	3911 N OESTE AVE	91604	2	159B161   154	2384024024	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	08/03/2020 12:00:00 AM	ADDRESS	34.13452	-118.41018	POWER PLAN CHECK FOR A NEW 600A 120/240V SINGLE PHASE 3W RESIDENTIAL SERVICE FOR NEW SINGLE FAMILY DWELLING. SCOPE INCLUDE NEW 10HP ELEVATOR. PERMIT FOR SERVICE EQUIPMENT, PARTIAL FEES PAID UNDER COMBO PERMIT # 15010-10000-00541.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47319	17041-20000-31364	11100 W SANTA MONICA BLVD S Garage	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.04726	-118.44465	Replacement of fluorescent lighting fixtures to new LED types in two separate parking garage structures.  Plan check for energy for both South and West garages.  Permit is for South Garage only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47320	11041-10000-02004	1055 W WILSHIRE BLVD	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	04/22/2011 12:00:00 AM	ADDRESS	34.05232	-118.2629	ALTERATIONS IN EXISTING OFFICES-NEW CIRCUITSPLAN CHK IS FOR TITLE 24 AND 2EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47321	11041-10001-20632	1130-1138 E LAKE ST BLDG 26	90291	11	111B145    36	4243001040	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			08/28/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.00391	-118.45905	LINCOLN PLAZA APARTMENT BUILDING PROJECT.((((((((   ADDITION OF  THREE 20 AMPS ELECTRIC CHARGING STATIONS  EV.  )))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47322	19041-20001-22315	5330 N MANTON AVE	91367	3	171B093    76	2044011011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM			PC Approved	10/08/2019 12:00:00 AM	ADDRESS	34.16829	-118.64102	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, SCOPE OF WORK CONSISTS OF ADDING A 150A CIRCUIT BREAKER TO THE 225A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47323	15041-20001-11269	6360 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	34.18619	-118.5972	3.11.2016 - Plan check for modifications to approved set. Add controlled receptacles and occupancy sensor control in each guest room. Add Partial-Off occupancy sensors on 3rd and 4th floor corridors. Install new light in closets of each guest room. Change some guest room light fixtures. Changing to 3-way light switches in guest rooms. Changes clouded.---Plan check for power only.  Installation of two new 75 kVA transformers feeding four new panels in existing highrise hotel.  Loads will be feeding new guestroom lighting and refrigerators.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47324	17041-20000-44251	10915 N INDEPENDENCE AVE	91311	12	210B109   249	2706003003	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	04/28/2018 12:00:00 AM	ADDRESS	34.26869	-118.59086	Plan check for a PV1 ground-mounted PV system. System size is 11.2 kWac and consists of (40) modules, (40) micro-inverters, and (1) load center.$17.93 permit fee per State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47325	14041-20000-08617	9019 N BALCOM AVE	91325	12	195B129    92	2768030015	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.23438	-118.52152	PV1.  Install 9 kW roof-mounted PV system, interconnect with main service panel.  Central inverter standard plan.  36 modules: Canadian Solar CS6P-250P.  Central inverter: Fronius IG Plus v10.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47326	13041-10000-17796	860 S LOS ANGELES ST 7th floor	90014	14	126A211    98	5145013021	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.04085	-118.25367	permit to be pulled at EPC counter only. pc for energy only. TI TO EXISTING OFFICE. HIRISE. 7TH FLOOR***BEGIN PRINT: 331285 (7/5/13 15:35)BAS Number: 584097Address: 860 S LOS ANGELES-----------------------------------------------NO: 11111  -- Building/Electrical/MechanicalDO NOT ISSUE ANY PERMIT (BUILDING, MECHANICAL, OR ELECTRICAL) TOADD, ALTER, DEMOLISH OR CHANGE OF USE WITHOUT AN APPROVAL FROMCRA. THIS IS A HISTORICAL SIGNIFICANT BUILDING. THE EXCEPTION NOTREQUIRING SIGN OFF FROM CRA FOR TI ABOVE THE 2ND STORY DOES NOTAPPLY TO THIS BUILDING/STRUCTURE.Note:  If the permit is subject to CRA clearance and thisbuilding is also a City monument, instruct customer to obtainclearance from City Planning Office of Historic Resources priorto obtaining a CRA approval.(Created: KGILL / 11-23-11)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 100720  -- Building/Electrical/MechanicalThis site is located in a Community Redevelopment Agency (CRA)area. All applications within the Redevelopment Project Arearequesting a permit for construction, remodeling, improvements,alterations including seismic compliance, demolition and/or signsmust be referred to the CRA for a permit approval.(Created: WMCCONNA / 10-18-11)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~***END PRINT: 331285 (7/5/13 15:35)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47327	19041-10000-44491	9611 N BADEN AVE	91311	12	201B097   202	2724011043	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.24527	-118.61973	PV1. NEW ROOFTOP SOLAR MOUNTED SYSTEM. SYSTEM SIZE IS 9.8KW DC/ 9.4KW AC. SCOPE OF WORK INCLUDES 30 AC MODULES (SUNPOWER SPR-327-E-AC) AND PV 125 A SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47328	10041-20000-00089	933 S PARK VIEW ST 1-20	90006	1	132A201   336	5136002007	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Apartment			01/05/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Expired	10/30/2012 12:00:00 AM	ADDRESS	34.0541	-118.28277	NEW 4 STORY 21 UNIT APARTMENT BUILDING.  VARIANCE TOSEPERATE FIRE ALARMS HAS BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47329	14041-20000-07838	6330 W SAN VICENTE BLVD SUITE 305	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.06116	-118.36804	PC FOR POWER AND ENERGY. TI FOR NEW MEDICAL OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47330	13041-20000-30880	3155 N DONA MARTA DR	91604	2	159B173   649	2380022014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.12842	-118.37719	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.6KW AC USING MICROINVERTER STANDARD PLAN. ENPHASE M215. TOTAL OF 40 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47331	19041-10000-49984	20730 W DEARBORN ST	91311	12	198B109   156	2748037022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.23712	-118.58532	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS  ON FIRST FLOOR (INDOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47332	18041-10001-05969	10611 N TUJUNGA CANYON BLVD	91042	7	207B197  1083	2557017007	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.26147	-118.29376	SUPPL PLAN CHECK FOR UPGRADING THE EXISTING 100 AMP SERVICE TO 200 AMP INSTEAD OF 225 AMP.  New PV1 rooftop on a SFD, (21) modules with P370, (1) central inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47333	13041-10000-15044	1470 S CANFIELD AVE 1-7	90035	5	129B169   162	4305006005	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Apartment			06/10/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.05312	-118.38933	PLAN CHECK FOR POWER AND ENERGY. NEW 4 STORY 7 UNIT APARTMENT LOCATED IN A METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47334	15041-10001-35550	18135 W SHERMAN WAY	91335	3	186B125   875	2119028001	[Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM			PC Approved	06/07/2016 12:00:00 AM	ADDRESS	34.20134	-118.52851	"06/07/16Changes to an approved set of plans. Changes include replacing the pullsection and main distribution board. Relocating distribution board, ""DSH"" to an ajacent room. Adding ground detection/sensing for 3 phase 3 wire delta  system. All changes are made under delta 1. NOTE: PERMIT PULLED UNDER PCIS#15041-10000-35550(((((Power plan check for a service replacement of a 1600-Amp service with a 3-phase 3-wire @ 240V. new switchboard also being relocated to a new location."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47335	13041-10000-21390	900 N ALAMEDA ST PHASE-2	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.05855	-118.23671	TENANT IMPROVEMENT TO A COMPUTER ROOM #CR2. POWER PLAN CHECK. TOTAL 4 FLOOR, WORK DONE IS ON THE THIRD FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47336	12041-20000-21004	24710 W OVERLAND DR	91307	12	186B085    67	2017034007	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM			Reviewed by Supervisor	09/18/2012 12:00:00 AM	PIN	34.20774253	-118.66267566	Plan check installation of roof mounted 4.2 kw PV solar system. SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47337	14041-10000-15215	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM			PC Info Complete	06/06/2014 12:00:00 AM	ADDRESS	34.17705	-118.6144	New fire alarm system for a new recreation center.49 devices + pannel and annunciator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47338	17041-10000-23101	13451 W ALBERS ST	91401	4	174B157   808	2344009023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.17043	-118.4262	PC FOR PV SYSTEM USING 7.6KW AC USING CENTRAL INVERTER WITH 34 MODULES IN TOTAL.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47339	14041-10000-00749	1458 S SAN PEDRO ST #L-32	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in Fashion District retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47340	17041-20000-35677	7214 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.24853	-118.28905	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 1,789 sq. ft.Note: Building application has been generated under 17016-20000-26691	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47341	19041-10000-04324	5510 S LINCOLN BLVD STE 150	90094	11	102B157   355	4211022023	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	33.97299	-118.43051	T24 PLAN CHECK FOR EXISTING COMMERICAL BUILDING, TOTAL SQUARE FOOTAGE = 10,501 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47342	07041-20002-26058	1409 S BEVERLY DR	90035	5	132A167   267	4306002016	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			07/26/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.05475	-118.39552	(((SUPPLEMENTAL APPLICATION FOR CHANGES TO APPROVED SET OF PLANS. CHANGE IN MAIN SERVICE. RECHECK FAULT CURRENT. NO NEW EQUIPMENT AS BEEN ADDED. PLAN CHECK ONLY.))))6 UNITS  3 STORIES TOWNEHOMESRequest for Modification to separate Fire Alarm system filed .Methane detection syste is by others .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47343	12041-20001-23712	7080 W HOLLYWOOD BLVD #200	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.10134	-118.34445	Modifications to emergency lighting system for highrise building.  Work is on the second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47344	10041-10000-16207	1724 N HIGHLAND AVE 1-270	90028	13	148-5A185  63	5547011023	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	08/24/2010 12:00:00 AM	ADDRESS	34.10238	-118.3385	OUT DOOR LIGHTING ON AN EXISTING OUT DOOR SIGN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47345	15041-10000-03387	818 W 7TH ST #930	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM			PC Approved	02/04/2015 12:00:00 AM	ADDRESS	34.04895	-118.25943	ENERGY COMPLIANCE FOR CIRCUIT CONTROLS FOR 120-VOLT RECEPTACLES IN OFFICE SPACESPERMIT WAS OBTAINED ON 15041-9000-00540.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47346	15041-20000-31838	449 E 41ST PL	90011	9	114A205    16	5113005018	R2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	PIN	34.00845709	-118.26746205	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47347	16041-10001-43673	16913 W GAULT ST	91406	6	183B133   294	2227028016	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.19949	-118.50184	Change to approved set of plans. Changes include adding (1) module and (1) micro inverter to the plan. New system size is 4.95KWdc / 3.87KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47348	13041-20000-26259	1552 W ROCKWOOD ST	90026	13	135A207   285	5159013016	RD1.5-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.06355	-118.26143	New private school.  600 amp service, 30,000+ sq ft of Energy calcs.  Fire alarm is included in this plan check/permit.(((location in methane zone. methan alarm system required per methane level. methane alarm variance has been filed to separate methane alarm from electrical plans. Methane shall be provided under separate permit by others)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47349	15041-10000-28110	6701 S CENTER DR WEST 420	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	33.97907	-118.39369	TI TO AN EXISTING HIGH RISE COMMERCIAL.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 8152.  SCOPE OF WORK TO BE PEFORMED IN SUITE 420.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47350	15041-10000-43632	740 W 182ND ST	90248	15	063B201   114	6121020009	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM			No Progress	06/24/2016 12:00:00 AM	ADDRESS	33.86917	-118.28665	NEW 210KW FUEL CELL GENERATOR. UTILITY INTERACTIVE - NET METERED FUEL CELL GENERATOR. ASSOCIATED LOADS INCLUDED. INTERCONNECTED TO EXISTING MAIN SERVICE - 277/480V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47351	11041-10000-12890	101 N JUDGE JOHN AISO ST	90012	9	130-5A213  86	5161013905	PF-2D	Central	Central City	Historic Cultural		2074.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.05103	-118.24074	NEW FIRE ALARM (MONITORING) SYSTEM WITH FIRE ALARM PANEL AND DEVICES IN A 3-LEVEL, STAND-ALONE UNDERGROUND PARKING LOT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47352	18041-10000-20018	1350 N IVAR AVE BLG C-& PARKING	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM				NEW FIRE ALARM SYSTEM IN A NEW COMMERCIAL / PARKING BUILDING.BUILDING PERMIT #15010-10000-04706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47353	10041-10000-15771	14655 W BLYTHE ST 1-69	91402	6	189B149   324	2210020003	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Apartment			08/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.21532	-118.45271	3 story plus one garage apartment bldg. 226 devices and 4 panels	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47354	17041-20000-10120	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/29/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	33.95713	-118.3847	New fire alarm system for (N) 4-story apartment building over 2 levels subterranean parking.  (244) devices with FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47355	14041-10000-24052	930 S HILGARD AVE 1st floor	90024	5	135B153   541	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.06306	-118.44116	plan check for energy only per 2013 Energy standards. high rise. emergency lights installed. Total connected load less than 400A. Verify occupant load and if place of assembly. BLDG#:14016 - 10-17654 9/3/2014: INTERIOR REFURBISHMENT OF 1ST LEVEL LOBBY, LOBBY BAR, PRIVATE LOUNGE, ELEVATOR LOBBY, PASSENGER ELEVATORS, CONNECT LOUNGE, AND RECEPTION (TOTAL 5,556 SQ FT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47356	13041-20000-15134	11120 S HINDRY AVE #C	90045	11	087B173    72	4129038015	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/14/2013 12:00:00 AM	ADDRESS	33.93344	-118.3722	T24 FOR EXISTING FOOD PREP AREA. PLAN CHECK FOR ENERGY ONLY. 1171 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47357	16041-10000-12342	10250 W SANTA MONICA BLVD Suite 1270	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	Title 24 plan check only.  Total area = 1,059 sq. ft.T.I. to existing commercial office space.  New lighting and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47358	11041-20000-08789	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			PC Approved	07/07/2011 12:00:00 AM	ADDRESS	34.24253	-118.57768	Plan check for T24 Energy (general/emergency) lighting for electronic room (mfg)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47359	13041-20001-13850	20658 W LUGANO WAY	91326	12	213B109   277	2701064037	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	34.27903	-118.58353	Changes to approved set of plans. Two inverters instead of one and change to module layout. One 5kW inverter and one 3kW inverter for 8kW AC total. Zoning has been cleared on previous application.New rooftop PV System for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47360	12041-20001-29785	9711 N WHEATLAND AVE	91040	7	201B177   348	2544008014	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM			PC Approved	03/18/2013 12:00:00 AM	ADDRESS	34.2458	-118.35761	20.02kW DC System.Lost set of plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47361	19041-20000-46939	11766 W WILSHIRE BLVD ste 540	90025	11	129B145  1202	4263008064		West Los Angeles				2674.04	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.04804	-118.46227	T24 PLAN CHECK FOR LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1123 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47362	17041-20000-33194	6865 W FOOTHILL BLVD	91042	7	202-5A201 529	2568020042	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.24792	-118.2816	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,000 sq. ft.Note: Building permit has been issued under 17016-30000-14371	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47363	15041-20000-16125	8059 N BRIMFIELD AVE	91402	6	189B149   150	2209015030	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.21749	-118.45842	Plan check for PV roof mounted system. System size 6.0kW with 26 modules and 1 inverter(6.0kW). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47364	18041-10000-28156	120 S SAN PEDRO ST	90012	14	129A213    16	5161017029	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM			Reviewed by Supervisor	08/07/2018 12:00:00 AM	ADDRESS	34.04937	-118.24147	FULL PLAN CHECK FOR REMODELING OF EXISTING BANK SPACES , OCC. LOAD > 100. NEW LOADS FOR LIGHTING AND POWER FED FROM EXISTING PANELBOARDS. TOTAL AREA: 5,552 SQ.FTBUILDING PERMIT # 18041-10000-28156	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47365	19041-20000-11449	14948-14958 W DELANO ST	91411	6	177B145   382	2242024020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.18241	-118.4591	Service upgrade to 800A 240/120V 3ph-4w in (E) commercial multitenant building.  Changeout of tenant panels; reconnection of (E) loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47366	18041-20001-42874	8426 N SUNLAND BLVD	91352	6	192B177   217	2404023014	(Q)C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.22351	-118.3653	Revisions to approved set of plans - delta C revisions only.  New X-ray room panel, feeder/wiring detail changes, other miscellaneous details. (((Plan check for power and energy. Project site is a existing tenant space in a commercial building. Project scope is a change of use from retail to medical office. Total lighting area = 1,421 sq. ft.Note: Building permit has been issued under 18016-20000-18325)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47367	16041-10001-29528	821 S MATEO ST	90021	14	123A217    49	5166017013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			PC Approved	09/16/2016 12:00:00 AM	ADDRESS	34.03285	-118.23244	Expedite fees only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47368	15041-10002-16514	6411 W IMPERIAL HWY	90045	11	087B165    12	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	33.93238	-118.3989	01/19/2016CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES ON DELTA 2, CHANGE OF DEVICES.(((Modification to approved set.  Additional 5 devices added to scope of work.  )))(((New fire alarm system for a single story commercial building with (1) fire alarm panel, (2) power supplies and (45) fire alarm devices.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47369	17041-10001-22173	1723 S LIVONIA AVE	90035	5	129B169   976	4305023020	R1V2	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.04828	-118.38688	PC only for relocation of three rooftop pv panels from detached garage to main house.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47370	19041-10000-03799	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.11883	-118.2495	FULL PC FOR A NEW 3-STORY S-2 OPEN PARKING STRUCTURE WITH A PEDESTRIAN BRIDGE THAT CONNECTS LEVEL 2 OF THE PARKING STRUCTURE TO THE EXISTING POLICE STATION. THE NEW BUILDING IS FED FROM AN EXISTING SERVICE PANEL. SCOPE INCLUDES NEW PANELS, EQUIPMENT, RECEPTACLES AND LIGHTING. TOTAL AFFECTED AREA IS 93,569 SQ.FTB#: 19010-10000-00444	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47371	11041-20000-12872	2049 S CENTURY PARK EAST #1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Info Complete	06/21/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	Ti in an existing office #1940. EPC is for T24Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47372	12041-20002-23641	3658 W 3RD ST	90020	10	135B197   188	5502005053	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Expired	07/01/2015 12:00:00 AM	ADDRESS	34.06889	-118.2959	Changes to approved set of plans. Plan check for Delta 1. Service load calc. Fault current calc.Modification to previously approved set of plans.  The modification is to relocate the service.  The site is located in a methane zone.  Existing permit. 12041-20000-23641.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47373	12041-10000-13879	470 E SWINFORD ST	90731	15	021B201   230	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	33.74945	-118.2748	Catalina Express, Berth 95 at the port of LA.  Place of assembly.  Change to lighting, new panels, circuits, loads.  Full Plan Check.  (FINAL FEE VALUE TO BE VERIFIED BY PLAN CHECKER)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47374	17041-10001-26143	5602 W MANCHESTER AVE	90045	11	096B173   123	4125018020	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			PC Info Complete	08/23/2017 12:00:00 AM	ADDRESS	33.95967	-118.3791	PC FOR TI FO NEW DENTAL CLINIC. CHANGE OF USE. PC FOR MEDICAL REQUIREMENTS ART. 517.PC FOR POWER AND ENERGY. PC ONLY - PERMIT UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47375	19041-20000-42617	4025 N VERDUGO VIEW DR	90065	1	154-5A219 156	5472005022	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.1182	-118.22559	Plan check for energy storage system install into existing PV system, Tesla PowerWall 2.0 13.5KWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47376	11041-10000-08373	6120 N LINDLEY AVE BLDG 1	91335	12	177B125   657	2123024025	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	34.1812	-118.52711	NEW FIRE ALARM FOR CHILD'S WORLD SCHOOL BUILDING #1.  3 SEPARATE BUILDINGS USING ONE CONTROL PANEL.  BUILDING #1 (6120 LINDLEY), BUILDING #5, AND BUILDING #2 (61121 LINDLEY).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47377	14041-20000-28729	16964 W PAULETTE PL	91344	12	219B133   274	2609025032	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.29833	-118.50224	PV1.  Install 8.84 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47378	17041-10000-32011	6530 N SEPULVEDA BLVD 1-68	91411	6	180B145   491	2235002005	R1-1-RIO, R4-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.18936	-118.46595	PC for new fire alarm for five story apartment building with two subtarrenean levels. PC for 1 FACP, 4 RPS panels, one annunciator panel and 223 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47379	17041-30001-40731	101 S LA BREA AVE	90036	5	138B181   853	5513019042	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Issued	02/06/2018 12:00:00 AM	ADDRESS	34.07338	-118.34425	02-06-2018 Changes to an apporved set of plan. Changes include replace with different lighting fixtures. Changes as been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47380	13041-20002-07316	11121 W PENDLETON ST	91352	6	198B173    45	2538011010	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.23852	-118.37336	Modification to approved set.  Removal of inverter from SLD; feeder to inverter specified as C.O. - installation of PV system by others under future permit.   (((PLAN CHECK POWER AND ENERGY FOR NEW METAL BUILDING RECYCLING MATERIAL SORTING FACILITY AND TRANSFER STATION. 4000A SERVICE. SITE LOCATED IN METHANE BUFFER ZONE LEVEL II. NO METHANE MITIGATION REQUIRED PER REPORT)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47381	14041-10000-31490	10800 W MAGNOLIA BLVD	91601	2	171B177   705	2419008038	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.16477	-118.36612	Facade renovation of single-story commercial retail building.  Plan check for energy for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47382	16041-10000-05409	22222 W VICTORY BLVD BLDG H	91367	3	177B101     5	2146002040	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Apartment			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.18623	-118.61159	REPLACEMENT OF EXISTING RECESSED DOWNLIGHTS AT EXTERIOR ELEVATOR LOBBIES AND LAUDRY ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47383	17041-30000-44043	4327 N BECK AVE	91604	2	165B169   520	2365026004	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.14807	-118.38348	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (1) load center, and (30) modules. Standard plan is bein used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47384	18041-20000-23764	17304 W WESTBURY DR	91344	12	219B133   304	2608016028	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.29801	-118.51027	PV1.  Install 13.865 kW DC roof mounted grid tied PV system.  (47) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47385	16041-20000-10775	21600 W OXNARD ST SUITE 2000	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.179	-118.6002	PLANCHECK FOR T24 ENERGY. TI FOR OFFICES. SUITE 2000.  10778 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47386	10041-20000-18560	10889 W WILSHIRE BLVD	90024	5	132B153   290	4363022019	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			09/20/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	34.05908	-118.44352	PLAN CHECK ONLY. PLAN CHECK T-24 ENERGY FOR OFFICE, SECURITY OFFICE, CONFERENCE ROOM, AND OUTDOOR LIGHTING. EXISTING WIRING. PERMIT FOR NEW FIXTURES AND MANDATORY MEASURE CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47387	17041-20001-43135	6050 W CADILLAC AVE	90034	10	126B173  1006	5066001048	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM			Reviewed by Supervisor	12/04/2017 12:00:00 AM	ADDRESS	34.03776	-118.37635	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47388	18041-10000-36480	11616 W BURBANK BLVD	91601	2	174B169   875	2350001095	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Apartment			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.17192	-118.38543	Plan check for a fire alarm system for a 3-story apartment building. Scope includes (1) fire alarm panel, (1) power supply and (72) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47389	19041-10000-23554	8760 S MAIN ST	90003	8	096A205   134	6041003046	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Issued	06/20/2019 12:00:00 AM	ADDRESS	33.95772	-118.27367	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47390	16041-10001-39398	2828 N NEWELL ST B	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	PC FOR TI TO SUIT B. NEW LIGHITNG. PC FOR T24 ENERGY ONLY. NEW OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47391	15041-20000-07076	5055 W WILSHIRE BLVD 7th Floor	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.06235	-118.34036	TI to office space. Title 24 Plan check for energy only. Adding new lighting including emergency. 7th Floor of high rise building.  (11,927 S.F.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47392	17041-10000-43715	7525 W SUNSET BLVD	90046	4	147B177   982	5550010020	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.0982	-118.35355	PC for T24 only for restuarant TI. Total area is 850sqft (indoor+outdoor). Installing new panelboard, receptacles, lights and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47393	19041-20000-24827	3339 N ALANA DR	91403	5	159B141   368	2280025023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.13164	-118.47791	Plan check for a PV1 roof-mounted PV system. System size is 6 kWdc/5.48 kWac and consists of (20) modules, (10) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47394	14041-20000-26484	5250 N LANKERSHIM BLVD suite 550	91601	2	171B173   367	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			PC Info Complete	09/25/2014 12:00:00 AM	ADDRESS	34.16668	-118.37545	ti to an existing high rise building, first time tenant.  adding lighting and 1 subpanel.  work to be performed on suite #550. plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47395	14041-10000-31990	333 N BELMONT AVE	90026	13	136-5A207 221	5159003006	R4-1	Central	Westlake	Greater Echo Park Elysian		2083.02	Electrical	Electrical	Apartment			11/18/2014 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.06787	-118.26342	Plan check for power and title 24.  New 69 unit 4 story apartment building.  45 typical units with 42,050 sq. ft. of common area.  New 2,000 A service.  Fire alarm seperation variance has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47396	19041-10000-31841	812 N CHESTNUT AVE	90042	14	154-5A235 175	5493037004	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	34.11781	-118.17085	Plan check for a fire alarm system located in a 2-story, 5-unit apartment building. Scope includes (1) fire alarm panel, (1) power supply, and (17) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47397	19041-10000-40024	11509 N LAUREL CANYON BLVD	91340	7	213B149   396	2613027019	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.27887	-118.45394	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS UPGRADING FROM FLUOURSCENT LIGHTS TO LED, WILL BE USING EXISTING CONTROLS AND CIRCUITS. TOTAL AFFECTED AREA IS 1418 SQFT. B# 19016-10000-24609	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47398	11041-10000-22240	1788 S LA CIENEGA BLVD	90035	10	126B173   172	5066006011	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	10/26/2011 12:00:00 AM		Permit Closed	02/06/2012 12:00:00 AM	ADDRESS	34.04498	-118.37655	T.I. to an existing office building.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47399	18041-20000-04008	4619 N CARITINA DR	91356	3	168B117   516	2178020013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Issued	03/07/2018 12:00:00 AM	ADDRESS	34.15408	-118.5566	PV1.  INSTALL A NEW 13.8KW PV SYSTEM ON A SINGLE FAMILY HOME.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47400	14041-20000-26035	5667 W SPREADING OAK DR	90068	4	153A191   179	5587002016	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.11419	-118.3143	PV1.  Install 4.59 kW roof-mounted, utility-interactive PV system.  Microinverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47401	13041-10000-19611	11643 N GLENOAKS BLVD	91331	7	213B157   324	2524022006	C2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Apartment			07/24/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.28129	-118.42005	NEW FIRE ALARM SYSTEM IN 1-STORY APT. THE INSTALLATION WILL INCLUDE CONTROL PANEL, SMOKE DETECTORS, HEAT DETECTORS, DUCT DETECTORS, PULL STATIONS, STROBES, HORN/STROBES. FIRE ALARM WILL BE INTERFACED WITH AC UNITS FOR SHUT DOWN. STROBES AND HORN/STROBES WILL BE PLACED PER NFPA 72. 83 TOTAL NUMBER OF FIRE ALARM DEVICES WITH 1 FACP AND 1 COMMUNICATION PANEL(UDACT).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47402	18041-20001-39752	17990 W MAYERLING ST	91344	12	216B125   163	2601018047	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM			PC Approved	10/20/2018 12:00:00 AM	ADDRESS	34.28874	-118.52513	Expedite per applicant requestPlan check for PV roof mounted and Energy storage system, PV System size: 13.32kW DC with 37 PV AC Modules and 1 Battery SONNEN BATTERY SYSTEM ECO 10(10KW DC, 7KW AC at 240V 1PH)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47403	17041-10000-09880	3995 S WESTERN AVE	90062	8	114B193   239	5035008024	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.01114	-118.30912	PC for energy only, Outdoor Title 24. Existing Popeyes restaurant, installing new facade lighting, esterior modification. Total area: 2,112.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47404	15041-10000-38328	3813 S MAPLE AVE	90011	9	117A205   516	5121026006		South Los Angeles				2311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.01287	-118.27241	PV1, INSTALL NEW 2.385 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(9) MODULES:KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47405	14041-10001-00287	19759 W RINALDI ST	91326	12	210B117   409	2701040039	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.27504	-118.56375	Existing permit,  Title 24 plan check  only,  total  remodel area is 2266 SQ feet(((PLAN CHECK FOR POWER AND ENERGY . TI OF STARBUCKS. EQUIPMENT RATED 600AMPS.BUIDLING P# 13016-20000-26394)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47406	18041-10000-00333	8471 W MELROSE PL	90069	5	141B173   425	5528001056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.08374	-118.37567	T-24, PC for energy only. TI to an existing retail space. Scope includes new lights and receptacles. Total affected area is B#17016-30000-37272	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47407	11041-10001-13927	6291 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM			PC Approved	11/21/2011 12:00:00 AM	ADDRESS	34.18382	-118.60178	Revision delta 3 (a) Fixture Type A lamp changed from fluorescent to LED (b) Fixture type D changed from 4 ft fluorescent to 26 watt CFL (c) additional Type A fixtures  for Handicap Parking (d) relocate electrical room (e) delete Panel EPP and ATS 2  (BRAND NEW 3-STORY PARKING STRUCTURE.  FULL PLAN CHECK.  Variance to separate the Fire alarm system was submitted on August 12, 2011.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47408	19041-10000-36313	3575 N CAHUENGA BLVD W #610	90068	4	159B177   196	2425008023	C2-1VL, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	PIN	34.13362778	-118.35843173	Energy plan check for an office T.I located on the 6th floor of a commercial building. Scope includes new lighting an equipment with a total lighting area of 7,400 SQ FT.Bld #: 19016-10k-22770	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47409	19041-20000-00988	4764 E BALTIMORE ST	90042	1	154-5A223  73	5477011004	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.11915	-118.21197	Installation of 13.5 kWh energy storage system.  (E) PV system on site and reconnected to (N) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47410	15041-20005-37382	7900 N BALBOA BLVD BLD. LIMA	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.21347	-118.50092	11/18/15Plan check for title-24, energy only. total area is 6020 sq. ft.  permit pulled under pcis#15041-20003-37382.((((Changed on the floor plan (15041-20000-37382), adding 5 branch circuit. )))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47411	16041-20001-33325	12918 W RUBENS AVE	90066	11	105B157   485	4223007023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM			PC Approved	10/05/2016 12:00:00 AM	ADDRESS	33.98447	-118.42877	expedite per applicantpv1install roof mounted pv system sized 10.2kw (acm) interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47412	17041-10000-28876	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	10/14/2020 12:00:00 AM	ADDRESS	34.21922	-118.44896	NEW FA SYSTEM FOR ADAPT REUSE OF BUILDING. APARTMENTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47413	16041-10000-20320	19339 W LONDELIUS ST	91324	12	195B117   109	2783025049	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.22999	-118.55496	PC for T-24 only. TI to an (E) commecial space: Change of use from Office and Manufacturing to Office and Motion Picture Film Editing. New load < 400A, total area: 9,550 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47414	19041-10000-08367	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM			Reviewed by Supervisor	04/02/2019 12:00:00 AM	ADDRESS	34.09676	-118.29487	ADDING ADDITIONAL 420 DEVICES AND 3 PANELS TO AN EXISTING FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47415	18041-20003-37685	7945 N BALBOA BLVD	91406	6	189B133   476	2204024014	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	12/24/2018 12:00:00 AM	ADDRESS	34.21512	-118.50149	3rd revision to an approved set of plans. downsizing the main pv to 100A and revisied the routing of pv conduit. all changes has been clouded. PC only. fees $0 due to california senate bill 1222 and assembly bill ab1414Revision to approved set of plans.  Change of inverter ratings to (1) 10 kW and (1) 7.6 kW rated string inverters.  Change of interconnection point into building wiring system.  Minor wiring revisions. (((Plan check for PV roof mounted system, system size: 23.76KW DC, 22.19KW AC with 72 PV Modules and 2 inverters(10.0KW) connected to 400A panel supply side connection)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47416	17041-20002-44984	6640 N VAN NUYS BLVD	91405	6	180B149   272	2237001018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			PC Approved	05/23/2019 12:00:00 AM	ADDRESS	34.19188	-118.44844	05-23-2019 Changes to an permitted set, Changes include  update fault current calculation  at the ATSs and Disconnects. All changes has been clouded. Plan check only. **********Previous Work Description**************Plan check for power and energy. TI/Change of use to medical clinic/surgical center. New 125kW emergency generator. T24 area - 3,002 sq ft. Not OSHPD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47417	19041-10000-44058	10321 N QUILL AVE	91040	7	204B189   460	2560015004	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM			Verifications in Progress	11/08/2019 12:00:00 AM	ADDRESS	34.25683	-118.31681	[EPLAN] NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 11.34 KW DC/ 11.4 KW AC, USING A SOLAREDGE CENTRAL INVERTER (SE11400H-US), WITH 36 MODULES (HANWHA Q CELLS), AND 36 SOLAREDGE OPTIMIZERS (P400).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47418	16041-20000-42989	16633 W VENTURA BLVD Suite 925	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for energy only. TI to office suite 925 in high rise building. New lighting (incl. emergency) and receptacles. 769sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47419	12041-10000-28507	2919 W LOS FELIZ BLVD ste #6	90039	13	157-5A207 375	5594006023	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/28/2012 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.12656	-118.26333	Agent for engineer is filing application.  T.I. for an existing Starbucks located in Suite #6 of a single story building.  Modification is being done to the interior lighting.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47420	18041-10000-08373	7029 W WILLOUGHBY AVE T2	90038	4	144B181   803	5532010041	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.08719	-118.34253	Tenant improvement on 1st & 2nd floors of media production officesplan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47421	18041-20000-31724	17109 W STARE ST	91325	12	204B133   522	2694009020	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.25316	-118.50577	Plan check for PV roof mounted system, system size: 7.6kW with 25 modules and 1 inverter(7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47422	11041-20000-23715	524 E RIALTO AVE	90291	11	108B145  1815	4238016029	RD1.5-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2011 12:00:00 AM			Verifications in Progress	01/03/2012 12:00:00 AM	ADDRESS	33.98897	-118.46636	PV SYSTEM  hard copy from city planning was provided on 11/18/11 for approval of solar clearance	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47423	11041-20000-07538	2154 W SUNSET BLVD	90026	13	139-5A207 104	5402030016	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	07/24/2012 12:00:00 AM	ADDRESS	34.07735	-118.26555	New roof mounted 20.5 KW P.V. system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47424	18041-20001-29935	24202 S STERLING RANCH ROAD	91304	12	192B089   196	2017039007	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.21939	-118.65406	change of address	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47425	17041-10000-43604	4310 W JEFFERSON BLVD	90016	10	120B181   772	5046008004	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.02541	-118.34329	FIRST TENANT-RESTAURANT- IN REMODELED COMMERCIAL BUILDING; PERMIT FOR CORE AND SHELL UPGRADE 17041-30000-16666 HAS NOT BEEN FINALISED AT THIS TIME.BUILDING PERMIT FOR CORE AND SHELL UPGRADE IS 17016-10000-26137	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47426	13041-10000-11987	11444 W OLYMPIC BLVD	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.03654	-118.44363	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING IN EXISTING COMMERICAL LOCATION. REMOVE AND REINSTALL > 50% OF LIGHTING. 11964 SQ FT. REMINDER: ALL TITLTE 24 PERMITS SHALL BE OBTAINED TROUGHT THE ELECTRICAL PLAN CHECK COUNTER. SCOPE OF WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47427	13041-20000-12710	4626 W HOLLYWOOD BLVD	90027	13	147B197   481	5542014009	[Q]C2-2D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.0998	-118.29018	Plan check for energy and emergency lighting. Low-rise commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47428	19041-20001-19372	2476 E HUNTER ST	90021	14	121-5A219  79	5168030001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.02749	-118.22728	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CHANGE TO SINGLE LINE SERVICE UTILTIY CONDUCTOR SIZE, CLOUDED CHANGE ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47429	18041-20001-12011	9336 W WAYSIDE DR	91040	7	207B185   522	2549017009	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.26102	-118.33471	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (35) modules. System is interconnecting with a 400-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47430	09041-20006-24723	15301 W LANARK ST	91406	6	189B145    41	2654037029	R4-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM			PC Approved	03/21/2013 12:00:00 AM	PIN	34.2183683	-118.4669973	"Modification to previously approved set of plans.  The only change is the breaker type for series rating of MSR-1 and MSR-2 due to motor contributions.   PLAN CHECK ONLY FOR DELTA ""A"" ON SHEET E.03 & E0.3B.    <<<NEW 87-UNIT ""AFFORDABLE SENIOR HOUSING"">>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47431	17041-10000-13093	6150 W 96TH ST	90045	11	093B165   121	4124027906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	33.94871	-118.39284	PC for temporary power installation. Temporary connecting 7 existing panels to existing switcboard MSB.Total connected load under 400 A, PC per inspectors request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47432	16041-10000-41275	1433 E 55TH ST	90011	9	108B209   607	5104010016	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	33.99313	-118.24901	PV INSTALL  3920 W DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(14) MODULES: HANWA Q-CELL. Q PLUS-G4 280W(1) INVERTER: SOLAREDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47433	15041-10000-00902	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"Plan check for T-24 only. Replace existing fluorescent light sign to LED. Retrofit existing fluorescent light sign to LED. sing with with new face Panel. Added new LED sign connect to existing power circuit. PROPOSED 3'-0 X 10'-0"" Over head type sign (6-1), (6-2), (6-3), and (6-4)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47434	10041-10000-18711	8500 W BEVERLY BLVD # 778	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF AN (E) 2000 S.F. RETAIL SPACE. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47435	14041-10000-27169	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	09/29/2021 12:00:00 AM	ADDRESS	34.04342	-118.25478	PLANCHECK FOR POWER AND ENERGY.  ADAPTIVE REUSE BUILDING. Conversion from office space to residential/mixed use building. 8 Story building with 7 units and commercial on the first floor.Permit must be obtained by 1/29/2018. No additional time extensions will be approved.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47436	18041-10000-23808	906-908 E 80TH ST	90001	9	099B209   385	6029005026	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.9664	-118.25829	PLAN CHECK FOR ROOF MOUNTED PV(SYSTEM 2 OF 2) SYSTEM - TOTAL SIZE IS 5.0 KVA CONSISTING OF 1 CENTRAL INVERTER (SUNNY BOY-5.0US) WITH 17 MODULES NOTE: PROJECT TO BE ASSIGNED TO ONE PLAN CHECKER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47437	11041-10000-18357	6750 W SANTA MONICA BLVD	90038	4	144B185   764	5532027016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.09057	-118.33767	ADDITION OF SECOND LEVEL OFFICE AND EXTERIOR DECK. REPLACE EXISTING WINDOWS/DOORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47438	10041-30000-01994	789 N AMALFI DR	90272	11	126B133    78	4408013008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2010 12:00:00 AM			PC Approved	02/05/2010 12:00:00 AM	ADDRESS	34.04383	-118.51032	Dickerson Residence/Complete plan check for 600A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47439	18041-10001-01810	10036 N ILEX AVE	91331	7	204B161   708	2624001001	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM			PC Approved	02/05/2018 12:00:00 AM	ADDRESS	34.25266	-118.40943	PC for changes to appoved set. Shifting PV module on roof. PC per applicants request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47440	13041-10002-12380	7260 W HAWTHORN AVE 1-25	90046	4	147B181   443	5548010018	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			10/08/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.0996	-118.34834	[[[[10/8/14 CHANGES TO APPROVED SET OF PLANS. DELTA 2 CHANGES ONLY. ADDITION OF 4 SUMP PUMPS IN HOUSE PANEL]]]]]PLAN CHECK FOR NEW 4-STORY, 25 UNITS APARTMENT BUILDING OVER SUBTERRANEAN GARAGE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47441	16041-10000-07671	17383 W SUNSET BLVD 1st fl.-BLDG A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	Interior T.I. to 1st floor main lobby, elevator lobby, and restrooms; Area of work 1645 s.f.. PC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47442	16041-10000-39023	5243 E REMSTOY DR	90032	14	147A237   152	5309009045	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.09748	-118.1658	PV Installation of NEW  5.88 KW AC ROOF-MOUNTED SOLAR ARAY. (21) MICROINVERTERS: ENPHASE 280(21) MODULES: DIAMOND SERIES  ASM6610P	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47443	14041-10000-00379	1200 S SAN PEDRO ST #101	90021	14	124-5A211 326	5132012051	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	PIN	34.0334209	-118.25310746	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 1128 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47444	18041-10000-10197	2404 S BARRINGTON AVE	90064	11	123B153   763	4260033038	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.03139	-118.44531	PC FOR ENERGY ONLY, TI TO  EXISTING RESTAURANT, SCOPE OF WORK INLCUDES EXISTING LIGHTING AND NEW LIGHTING FOR RESTROOM. TOTAL SQ. FT. 1426.RESTROOM SQ.FT  63B#18016-10000-00450	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47445	19041-10000-53010	1817 W 41ST DR	90062	8	114B193   589	5022002004	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.00915	-118.31192	NEW PV1 INSTALLATION 4.88KWdc (4.47KWcec-ac & 3.8KWac) USING 16 QP305 MODULES, 16 SE P320 POWER OPTIMIZERS & 1 SE3800H-US CENTRAL INVERTER.CONNECTED T AN EXISTING 100 AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47446	18041-20000-36706	10741 N DELCO AVE	91311	3	183B125   454	2126008009	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.26536	-118.57844	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47447	13041-10000-02762	754 S WALL ST	90014	14	126A211   123	5145005008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	02/04/2013 12:00:00 AM	ADDRESS	34.04061	-118.24966	TI TO EXISTING COFFEE SHOP. PC FOR ENERGY. 792SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47448	16041-10000-20178	809 S HILL ST 807,809,-813,815	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.04431	-118.2562	CORE AND SHELL UPGRADE OF EXISTING BUILDING.  INSTALLING NEW 1600A SERVICE MS-B  AND HOUSE PANEL WITH 3 CONDUIT STUBS FOR FUTURE TENANTS.Building located on Methane (Buffer) zone per Zimas.B#15016-10000-26929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47449	13041-10000-25754	20253 W DELITA DR	91364	3	171B113   383	2166039022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.16286	-118.57555	PV1.  Install 10kW DC roof-mounted solar array, interconnect with main service panel.  Central inverter: Fronius IG Plus V 7.5. 40 modules: Trina Solar TSM-250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47450	12041-10000-29680	10041 N LARWIN AVE #1	91311	12	204B097    19	2724003***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			12/10/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.25546	-118.61797	PV1 PLAN CHECK ROOF MOUNTED 5.46KW PHOTOVOLTAIC INSTALLATION USING AURORA TRANSFORMERLESS INVERTER FOR CONDO UNIT #1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47451	17041-10000-32993	11906 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.05239	-118.47055	PC FOR RESTARUANT/CAFE  TI FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD <400A SCOPE INCLUDES NEW PANEL CIRCUITS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1202 SQ.FT.  B# 17016-10000-24783	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47452	14041-20000-33323	7640 N TAMPA AVE #C1, C2, D	91335	3	186B117   112	2104012066	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.20967	-118.55333	CHG OF USE FROM OFFICE TO MEDICAL OFFICE. PC FOR POWER AND ENERGY. NON OSHPD PER APPLICANT. PLAN CHECK FOR APPLICABLE REQUIREMENTS OF ARTICLE 517.  Note. Plan check is for core/shell and owner build out; Future T.I for each individual unit will require a separated permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47453	10041-10000-01609	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00, 2699.01	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	03/25/2011 12:00:00 AM	ADDRESS	34.03145	-118.41085	Install a new 2.5KW PhotoVoltaic System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47454	10041-20000-12048	2827 S HOOVER ST	90007	8	121-5A201  45	5055028001	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	12/07/2010 12:00:00 AM	ADDRESS	34.02859	-118.28415	INTERIOR REMODEL ON 2ND AND 3RD FLOORS.  office T-24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47455	12041-20000-11659	19755 W VANOWEN ST #A-2-a-28	91306	3	183B117   835	2135022005	(T)(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Closed	12/04/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	Space #12 tenant developmentComplete plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47456	19041-10000-22512	550 S HOPE ST # 450	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47457	18041-10000-21206	3217 N EASTERN AVE	90032	14	141A233    26	5213038036	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2014.01	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.08244	-118.17829	TWO TENANT SPACES CONVERTED TO ONE TENANT SPACE FOR OFFICENEW CIRCUITS AND LIGHTING; FIRST TENANT IN SPACES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47458	11041-10000-11179	7300 W HOLLYWOOD BLVD	90046	4	147B181   182	5550016024	[Q]R5-1	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.10144	-118.34913	at existing school, remodeling classrooms, restrooms, corridors at main and upperlevels of the buildingplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47459	17041-20000-33935	11051 W PENDLETON ST	91352	6	198B173    32	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM			Reviewed by Supervisor	11/03/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	Plan check for feed-in-tariff solar pv system, roof-mounted array on commercial building.1.562MW ungrounded system [(19) 80kW + (1) 42kW].(5,580) 380W pv modules.2,500A 480V 3ph 4w service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47460	16041-20000-02104	10842 W MAGNOLIA BLVD	91601	2	171B173   641	2419008056	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Apartment			01/20/2016 12:00:00 AM			Reviewed by Supervisor	03/03/2016 12:00:00 AM	ADDRESS	34.16477	-118.36729	New 46 unit apartment. Plan check for power and energy. Adding new lighting including emergency. Total sqft. 41,799.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47461	16041-20001-24249	11136 W CANTLAY ST	91352	2	183B173    59	2315028005	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Apartment			07/11/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.20199	-118.37378	EXPEDITE PER APPLICANT REQUESTPV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47462	14041-10001-10436	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Change to approve set of plan. Change 2 panels from (2) 200Amps panel to (1) 400Amps and (1) 200Amps panel. NOTE: Approve set of plan will be drop off on (02-05-15 or 02-06-15) per applicant((((PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT STARBUCKS ON AN EXISTING SWITCHBOARD.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47463	13041-10000-24414	9665 N JUMILLA AVE	91311	12	201B117   488	2761030057	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.2456	-118.56338	PV1 INSTALLING ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 13.25 KWDC ON CENTRAL-INVERTER NON-STANDARD PLAN, TRANSFORMERLESS.(53) MODULES: TRINA SOLAR #TSM-250PC05/PA05.18(2) INVERTER: POWER-ONE #AURORA PVI-5000-OUTD-US, POWER-ONE #AURORA PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47464	19041-20000-42512	8208 N GEYSER AVE	91335	12	192B121   892	2103004007	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.21965	-118.5425	PV1. INSTALL (28) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47465	14041-10000-18864	12746 W JEFFERSON BLVD suite 2200	90094	11	102B161  1237	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Closed	03/18/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE TO RESTAURANT. NEWLY CONNECTED LOAD > 400 AMPS. SUITE 2200.BUILDING PERMIT # 14016-10000-06608 .Change of use from retail to restaurant for space approved under building permit 12014-10000-01098	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47466	16041-20000-27582	550 S HILL ST 1 st floor	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.04753	-118.25268	Plan check Title 24 only in existing Bank T.I. Total area: 8,936  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47467	18041-20003-38825	20105 W RINALDI ST #100-110	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			PC Approved	08/16/2019 12:00:00 AM	ADDRESS	34.27543	-118.57209	Plan check only. Revisions to approved set.  Addition of details to single line and legends table. Update to Panel C load schedule values  Changes on sheets E-1 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47468	15041-10000-27142	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.93845	-118.42964	PLAN CHECK FOR POWER AND ENERGY.NEW  BUILDING WITH TYPE IIB  2-STORY OFFICE   AND 1--STORY AIRCRAFT HANGER BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47469	16041-10003-39304	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES TO SINGLE LINE AND PANELS. LOAD UPDATE. NO ADDITIONAL LOADS NOTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47470	14041-20000-29437	17144 W LORNE ST	91406	6	189B133   215	2204007009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Expired	11/17/2016 12:00:00 AM	ADDRESS	34.21712	-118.50715	PV1CENTRAL STRING INVERTER STANDARD PLAN SIZED 3.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47471	16041-20000-09177	17500 W RINALDI ST	91344	12	213B129   308	2711022028	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.27917	-118.5155	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (23) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47472	10041-10002-24535	13488 W MAXELLA AVE	90292	11	105B153    78	4212004012	[T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Public Safety Only			03/20/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	New fire alarm sytem for an appartment building. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47473	18041-20000-33431	20722 W BEECH CIR #300	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.29286	-118.58511	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47474	16041-10001-31360	2174 W 30TH ST	90018	10	120B189   374	5052025011	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.02728	-118.31431	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGNING POINT OF INTERCONNECTION AND UPGRADING THE SUBPANEL. ALSO CHANGE OF ADDRESS. CORRECT TIE IN ADDRESS IS 2174 W 30TH AS SHOWN ON THIS PERMIT. PERMIT ALSO INLCUDE NEW LOAD CENTER BEING INSTALLED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47475	19041-20000-49848	19248 W ALLANDALE DR	91356	3	162B117   384	2177043015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Expired	04/04/2024 12:00:00 AM	ADDRESS	34.13704	-118.55277	Plan check for PV roof mounted system, PV system size: 10.0KW  AC, 11.34KW DC with 36 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47476	16041-20000-23617	4040 N BERENICE PL	90031	1	144A225   216	5304005016	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.08927	-118.20338	PV1INSTALL ROOF MOUNTED PV  SYSTEM SIZED 3KW, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47477	14041-20000-20609	1636 W 8TH ST	90017	1	130-5A205 112	5142017021	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.05263	-118.27317	PV2.  Install 81.0 kW roof-mounted, utility-interactive PV system.  (9) Power One PVI-8.6-TL-OUTD-US-A transformerless inverters w/ DC AFCI protection.  324 modules.Note: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47478	15041-10000-36681	1888 CENTURY PARK EAST 5TH FLR	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	PIN	34.06160176	-118.41389445	PC FOR ENERGY. OFFICE, HIGH RISE BUILDING, 5TH FLOOR. TOTAL AREA 1785 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47479	14041-10000-08021	8938 W CADILLAC AVE	90034	10	126B169   847	4302017013	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.0405	-118.38593	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS STANDARD PLAN. SYSTEM SIZE: 7.395 KW DC.(29) RENESOLAR JC255M MODULES(1) POWERONE PV1 6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47480	14041-20000-21439	6514 N KEOKUK AVE	91306	3	180B113   641	2134021014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Expired	09/08/2016 12:00:00 AM	ADDRESS	34.18867	-118.57392	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(25) TRINA SOLAR TSM255 MODULES(25) SOLAR EDGE POWER OPTIMIZER P300(1) SOLAR EDGE SE6000 TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47481	16041-20000-13046	15105 W MISSION HILLS ROAD	91345	7	213B145    24	2664022013	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Apartment			04/14/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.28165	-118.4621	Plan check for power and energy. Project site is an existing commercial 3-story building (assisted-living apartments). Project scope is an addition of 44 units (3-stories) to the existing building. Note: Building application has been created under 16014-20000-01659	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47482	12041-10000-15763	4751 W WILSHIRE BLVD 205	90010	4	135B185   565	5505001021	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM			PC Approved	07/09/2012 12:00:00 AM	ADDRESS	34.06219	-118.3337	Plan check for energy and emergency lighting. Office (B Occupancy). 16230 sqft. Commercial low-rise. Suite 205.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47483	16041-20000-37699	15060 W VENTURA BLVD	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.15287	-118.46147	remove existing hid fixtures and replace with new led.  outdoors. plan check for energy 18050 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47484	16041-20000-33846	9251 N VANALDEN AVE	91324	12	198B121   476	2762035023	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.23876	-118.54932	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.7KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47485	15041-20000-26496	1973 N VAN NESS AVE	90068	4	150A191     8	5587016022	R1-1-HPOZ	Central	Hollywood	Hollywood United		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	09/10/2017 12:00:00 AM	ADDRESS	34.10731	-118.31602	Paln check for PV roof mounted system. System size: 4.5kW with 18 modules and 18 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47486	16041-10000-33847	639 N FAIRFAX AVE	90036	5	141B177   778	5527017007	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			09/23/2016 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.08281	-118.36175	PC FOR POWER AND ENERGY. NEW 63 UNITS APARTMENT BUILDING,  4-STORY, ONE LEVEL GARAGE AND ONE SUBTRANIAN LEVEL. 12-TYPE UNITS.SERVICE SIZE 1600A, 208/120 V 3 PHASE 4 WIRE. TOTAL AREA 59011 SQ FT.BUILDING APPLICATION 16010-10000-02964	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47487	17041-10001-37289	8619 S HAAS AVE	90047	8	097-5A191 317	6036001044	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM			PC Approved	11/13/2017 12:00:00 AM	ADDRESS	33.95936	-118.31736	EXPIDITE PER APPLICANT REQUESTPC FOR ROOFMOUNTED PV ON SFD. SYSTEM SIZE 3.0KWAC/3.0KWDCSCOPE INCLUDES SINGLE INVERTER WITH 10 MODULESPOWERWALL 2 BATTERY INCLUDED WITH  (UNDER SUPP.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47488	12041-10003-30549	8511 W BEVERLY PL	90048	5	138B173   350	4337012040	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM			PC Approved	05/05/2015 12:00:00 AM	ADDRESS	34.07669	-118.37705	TI-24 PC FOR ENERGY ONLY. CHANGING MODEL FIXTURES IN DINNING PANTRY.NEW  4 STORY  PRIVATE SCHOOL BUILDING OVER ONE SUBTERRANEAN LEVEL OF PARKING. PLAN CHECK FOR POWER AND ENERGY FOR AN ADDITION TO AN ACADEMY (CHARTER SCHOOL). PROJECT IS LOCATED IN A METHANE ZONE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47489	18041-10000-05363	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC for T24 only for sign lighting. Installing new LED signs for Dunking Donuts in LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47490	17041-10000-45062	301 S MUIRFIELD ROAD	90020	4	135B185   102	5505009012	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.0686	-118.32894	PC for rooftop solar for new 10.44kW(AC) system. Installing 29 AC modules with 125A load center and 200A subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47491	14041-20000-11921	6507 N BLUCHER AVE	91406	6	180B141   640	2234011014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.18881	-118.47297	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC WITH OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47492	13041-20000-14994	143 N OCEAN AVE	90402	11	120B129   164	4410004036	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.02751	-118.5152	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE: 10.46 KW. 32 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47493	19041-10000-30028	1003 E 4TH PL 8th flr	90013	14	127-5A217  55	5163018002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.04219	-118.23383	FOR INTERIOR TENANT REMODEL 8TH FLOOR ONLY. NON-STRUCTRUAL REMODEL PLAN CHECK IS FOR TITLE 24 ONLY-ADDED LOAD IS LESS THAN 400A	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47494	15041-10000-18138	12777 W JEFFERSON BLVD	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	33.9778	-118.41768	FULL PC, POWER AND ENERGY. NEW 5 STORY PARKING STRUCTURE. LOCATED IN METHANE ZONE WITH UNDERGOUND SERVICE. TOTAL SQ. FT. 224,153.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47495	16041-10000-14185	11881 W BRAY ST	90230	11	108B161   872	4218018043	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Issued	12/13/2016 12:00:00 AM	ADDRESS	33.98938	-118.40769	Installation of new Tesla PowerWall 6.4 kWh battery system interconnected to existing roof mounted solar system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47496	16041-20000-32999	23163 W LAUREN LANE	91304	12	186B093   727	2014033054	(Q)RD5-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.20883	-118.63183	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47497	17041-10000-24711	1218 S SANTA FE AVE	90021	14	121-5A217  29	5166007027	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.02903	-118.22976	Plan check for Title 24 only, remove HID fixtures indoor and replace with new LED fixtures, Total area: 5100 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47498	16041-20000-25268	400 W WORLD WAY TERMINAL-4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	TI TO AN EXISTING COMMERCIAL SPACE IN TERMINAL 4.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  TOTAL SQUARE FOOTAGE 60.  PLAN CHECK FOR ENERGY ONLY.  THIS IS PLAN CHECK ONLY.  PERMIT FEE UNDER APLICATION NUMBER 16041-30000-11049	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47499	18041-10000-20923	20739 W DEARBORN ST	91311	12	198B109   144	2748036022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.23733	-118.58579	*Permit fee is zero dollar per SB-1222/ AB-1414*PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 75.92 kW DC/ 72.08 kW AC, (208) modules, (2) central inverters, (1) 125A subpanel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47500	14041-20001-14970	3924 S DEGNAN BLVD PV1	90008	10	117B185  1133	5033015006	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.01391	-118.33028	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 1PV1. Install 3 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with power optimizers (DC-DC converters)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47501	17041-20000-36401	420 E 3RD ST ste 100	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.04686	-118.24182	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47502	16041-20000-29665	1425 N ALTA VISTA BLVD	90046	4	147B181   860	5548019054	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			08/22/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.09658	-118.34725	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is a remodel of the leasing office and lobby. Total lighting area = 1,145 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47503	12041-10000-04709	4816 N DON PIO DR	91364	3	168B105   716	2171019076	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2012 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.15496	-118.60367	INSTALL ROOF-MOUNTED 11.52KW SOLAR AND INTERCONNECT TO MAIN SERVICE PANEL. SERVICE PANEL UPGRADE TO 225A.  SINGLE STORY SINGLE FAMILY DWELLING 720 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47504	18041-10000-29639	25001 S DOBLE AVE	90710	15	036B197  1101	7413018***	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Issued	08/07/2018 12:00:00 AM	ADDRESS	33.79746	-118.29196	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47505	19041-10000-32003	9201 N OWENSMOUTH AVE	91311	12	198B105   144	2746012037	[Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	04/29/2020 12:00:00 AM		Permit Finaled	08/14/2020 12:00:00 AM	ADDRESS	34.23757	-118.60203	Permit fee is $0.00 due to AB1414PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 443 MODULES (SPR P17 330W), 222 OPTIMIZERS (P850 ), 2 INVERTERS ( SE 66.6K) SYSTEM SIZE IS 133.2KWac AND 146.2KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47506	11041-10000-06422	8500 W BURTON WAY	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47507	15041-20000-26435	515 S FLOWER ST 13th FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI to existing high rise commercial building (lounge). Plan check for energy only. Adding new lighting. Total sqft. 780	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47508	18041-20001-01968	16637 W RUNNYMEDE ST	91406	6	186B137   145	2226011017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	34.20632	-118.49588	expeditepv1install roof mounted pv system sized 5kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47509	14041-20000-25629	300 S GRAND AVE 1st floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	PIN	34.05243427	-118.25124731	TI to (E) commercial highrise office retail-level corridors and restrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47510	12041-10000-15808	3584 S FIGUEROA ST #2	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Closed	11/21/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	FIRST TENANT-restaurant Whichwich CHANGE OF USE: RETAIL TO RESTAURANT  INTERIOR TI, NEW PARTITIONS FINISHES, CEILINGS, MILLWORK approx 1300sqft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47511	11041-10000-00919	2000 S AVENUE OF THE STARS 2ND FL	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	05/10/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	TENANT IMPROVEMENTS IN THE CORRIDORS OF AN OFFICE BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47512	19041-10000-18581	6255 W SUNSET BLVD #620	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	Tenant improvement to the existing office tenant space #620. Installing new lights.T-24 Energy Only. Bulding Permit: 19016-40000-12272	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47513	14041-20000-01330	5033 N ORRVILLE AVE	91367	3	171B093   728	2047012035	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	07/12/2014 12:00:00 AM	ADDRESS	34.16226	-118.64388	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 12KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47514	19041-20000-36015	1940 S BEDFORD ST	90034	10	126B169   480	4302024019	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	Apartment			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	09/01/2022 12:00:00 AM	ADDRESS	34.0427	-118.38321	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN 3-STORY APARTMENT BUILDING. (53) FA DEVICES AND A FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47515	14041-10001-27214	1522 E COLON ST	90744	15	036B213   350	7426019017	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/30/2014 12:00:00 AM	ADDRESS	33.79175	-118.24464	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(6) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47516	16041-20000-44654	7179 W FOOTHILL BLVD	91042	7	202-5A199 450	2568014007	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.24867	-118.28837	Plan check for energy only. TI and addition to existing night club/banquet hall. New lighting (incl. emergency). 6,100sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47517	19041-20000-06702	1658 W CARSON ST	90501	15	051B193   977	7346003042	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM			Corrections Issued	02/25/2019 12:00:00 AM	ADDRESS	33.8313	-118.30868	Plan check for Title 24 only Tenant Improvement retail in existing space. Total area: 2,021 sq ft. B#18016-20000-10169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47518	18041-20000-04910	713 N CYPRESS AVE	90065	1	145-5A219 393	5453020024	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.09131	-118.22349	plan check for a roof mounted PV system for a commercial building. Plan check includes 20 modules with p370 power optimizers, and Solaredge SE6000. 6KVA system	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47519	16041-10000-10141	7950 W FOOTHILL BLVD	91040	7	204B193   174	2559006022	C2-1VL, R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Info Complete	03/23/2016 12:00:00 AM	ADDRESS	34.25936	-118.30626	T-24, PC FOR ENRGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW  LIGHTS. TOTAL AFFECTED AREA IS 2353 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47520	19041-10001-50617	1540 N SKYLARK LANE	90069	4	147B169   499	5561004028	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM			PC Approved	01/13/2020 12:00:00 AM	ADDRESS	34.09909	-118.3877	EXPEDITE FEESPV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 28.5 KWac/41.04KWdc. SCOPE OF WORK INCLUDES 114 MODULES (SOLARIA 360R-PD) WITH MICROINVERTERS (IQ7-60-2-INT), WITH FOUR COMBINER BOXES, A NEW 200A LOAD CENTER INTERCONNECTED TO AN EXISTING 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47521	14041-10000-30848	6943 N VALJEAN AVE	91406	6	183B137   308	2224022006	M1-1, P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.19676	-118.48601	Energy plan check for commercial building by replacing HID light fixture to LED fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47522	10041-10000-23329	10712 W VINEDALE ST	91352	2	195B177   524	2404009022	C2-1VL, R1-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1222.00	Electrical	Electrical	Public Safety Only			11/22/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Expired	01/17/2013 12:00:00 AM	ADDRESS	34.22857	-118.36411	REPLACING FA PANEL ; PANEL MONITORS 4 EA BELLS AND 9 PULL STATIONS -ALL FOR 16-UNITS APARTMENTS BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47523	13041-10000-04913	220 E 2ND ST 1-104	90012	9	130-5A213 175	5161024014	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			02/26/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Closed	02/05/2014 12:00:00 AM	ADDRESS	34.04978	-118.2429	TEMP POWER FOR 5STORY APARTMENT. 1600A TEMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47524	18041-20000-23165	305 S CLARENCE ST	90033	14	127-5A219  86	5172018011	MR1-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Info Complete	04/11/2019 12:00:00 AM	ADDRESS	34.0449	-118.22421	Plan check for power and energy. Project site is a new 1-story warehouse. Project scope is the core and shell. Work includes a 1600-amp service and a total lighting area of 12,187 sq. ft.Note: Building application has been generated under 17010-10000-03082	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47525	15041-10000-15011	1914 S BUNDY DR	90025	11	123B149   282	4259020013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.03484	-118.45635	Energy plan check for sport club (LA fitness) T.I.  Scope includes new lighting and receptacle outlets.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47526	13041-20003-35790	542 E ROSE AVE	90291	11	111B141   333	4240010008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM			PC Approved	04/07/2015 12:00:00 AM	ADDRESS	33.99853	-118.47286	Change to approve set of plan. Add 4  new circuits for Unit A and B for General light circuits per inspector request. Changes apply to delta 2 only on sheet E-5. ((((New mixed use with 2 residential units and retail space.  Full Plan Check for Power and Energy.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47527	17041-10000-29455	7800 N VINELAND AVE	91352	2	189B173   634	2409010025	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.21231	-118.37013	PC for T24 energy only, replace outdoor existing fixtures with LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47528	16041-10000-15042	12655 W JEFFERSON BLVD	90066	11	102B161    13	4211005019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	33.97916	-118.41469	FULL  PC FOR A COMMERCIAL T.I. IN A 6 STORY BUILDING. THIS APPLICATION WILL BE THE TI ON FLOORS 3, 4, 5, AND 6. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES CONNECTED LOAD > 400AMPS. . TOTAL SQ. FT. 78819.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47529	09041-10001-23766	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM			PC Approved	06/07/2010 12:00:00 AM	ADDRESS	34.04896	-118.25139	Revised single line diagram to show that the MS-4 is a 400A section and reconnecting the feeder directly to the existing ATS -14 switch; all the pump loads will be refed from another section in the near futur;E also installing a shunt-trip to elevator EL-5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47530	13041-10000-03733	2029 S CENTURY PARK EAST STE 1350	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY. 44 stories TI TO OFFICE. NOW A BRITISH CONSULATE. emergency lights. one existing exit sign	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47531	13041-10010-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta 30 revisions:  NEW CKTS/LOADS ON PANELS L4BM;L5BM;UPSPANELS AND DISTRIBUTION LOAD SUMMARYS UPDATED; ALL CHANGES ARE CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47532	11041-10002-27321	1801 E 50TH ST	90058	9	111A213   156	5106027004	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM			PC Approved	02/29/2012 12:00:00 AM	ADDRESS	33.99812	-118.24177	Plan check revision Delta 3 to approved plans. Changes consist of lighting layout, T24 calculation, and RTU location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47533	17041-10000-44392	13029 W VICTORY BLVD	91606	2	180B161   790	2326017013	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Apartment			12/11/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.18799	-118.4167	PC FOR RETAIL STORE (SPRINT) FOR T-24 ENERGY ONLY.TOTAL EFFECTED AREA IS 1770 SQ.FTSCOPE OF WORK INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. B# 17016-10000-36118	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47534	16041-10000-43867	4364 W FOUNTAIN AVE	90029	13	147A201   249	5542023046	C4-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.09564	-118.28513	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO VETERINARY CLINIC. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1115 SQ. FT. B#16016-10000-29803	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47535	16041-10001-01545	1851 W 82ND ST	90047	8	099B193  1274	6035009013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	33.96468	-118.31085	PV1. PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.42KWdc / 3.8KWac. (17) MODULES-Yingli Energy YL260P-29B(1)INVERTER-FRONIUS 3.8NOTE: PERMIT PULLED UNDER PCIS#16041-70000-01545 / X16SL00193 ((((Install a roof mounted photovoltaic system to existing single family dwelling (4.335      KW)Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47536	15041-20000-10536	10600 N PINYON AVE	91042	7	207B201   255	2566001076	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.26113	-118.28481	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC. THIS IS AN ADDITION OF THE 5KW AC SYSTEM. THE TOTAL PV BACKFEED ADTER INSTALL WILL BE 11KW AC. THIS PERMIT TO COVER NEW INVERTER, PANELS AND SOLAR COMBINER. THIS SYSTEM CONTAINS POWER OPTIMIZERS. THIS PERMIT ALSO COVERS RELOCATION OF EXISTING INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47537	15041-10000-20586	1455 N VAN NESS AVE	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.09728	-118.31598	PC FOR POWER. UPGRADING 2 OPTIONAL STANDBY 750 KW AC GENERATOR AND ADDING NEW 1200 A SWITCHBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47538	19041-20000-48480	18416 W CHATHAM LANE	91326	12	213B125   240	2870016036	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.28152	-118.53427	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 11.055 KW DC/10.141 KW AC. SCOPE OF WORK CONSISTS OF (33) PV MODULES WITH MICROINVERTERS AND A NEW LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47539	19041-10000-16109	5815 W 96TH ST APM-TPSS	90045	11	093B169   162	4125023931	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Issued	12/20/2019 12:00:00 AM	ADDRESS	33.94956	-118.38359	Full Plan Check, distribution from utility source to CTA West Station, CTA Center Station, ITF West and Traction powered substation at ITF East Station with (2) 12.4KV Feeders	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47540	14041-20000-15179	11310 W SHERMAN WAY Bld. #2	91605	2	183B173   112	2319001006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	PIN	34.19989971	-118.37702755	T.I. to existing building #2.  Install news 1600A service and panels. Plan check for power only.Note: Application for Bld. #1 is under 14041-20000-15176	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47541	19041-20000-49833	16204 W BERTELLA DR	91436	5	168B137   644	2284016022	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Issued	12/04/2019 12:00:00 AM	ADDRESS	34.15396	-118.48639	PV1 PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 7.56 KW DC/7.6 KW AC. ESS SIZE IS 40.5 KWH. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH OPTIMIZER, A 7.6 KW INVERTER, (3) 13.5 KWH BATTERIES, AND A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47542	15041-10000-02011	12861 W OSBORNE ST	91331	7	204B161   806	2623031012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.25196	-118.41292	PV1.  Install 8.28 kW roof-mounted solar PV system on single family dwelling.  (24) modules and (2) utility-interactive inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47543	10041-20000-08716	1118 S ABBOT KINNEY BLVD	90291	11	108B145  1151	4238003002	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM			PC Info Complete	08/24/2010 12:00:00 AM	ADDRESS	33.9915	-118.46999	CHANGE FROM RETAIL TO OFFICE AREA IN METHANE ZONE. EXISTING SERVICE. DOING NEW POWER LOADS AND LIGHTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47544	17041-20000-02476	3377 W WILSHIRE BLVD 202/204	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.06193	-118.29742	ti to an existing commecial building (dental office).  plan check for power and energy.  total square footage 2836 in suite 202 and 204	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47545	15041-20002-02007	1201 W 5TH ST SUITE 900	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM			PC Approved	05/08/2015 12:00:00 AM	ADDRESS	34.05429	-118.25967	"Changes to approved set.  New fixtures are being used.  Title 24 sheets have been updated.*****Previous Work Description*****TI TO AN EXISTING OFFICE COMMERCIAL HIGH RISE BUILDING.  NEW LIGHTING NEW CONTROLS USING EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN SUITE 900.  TOTAL SQUARE FOOTAGE 5062.""COMPLY WITH DEPARTMENT ORDER effective date 01/26/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47546	15041-20000-42326	6650 N CAMELLIA AVE	91606	2	180B169   375	2320022003	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.19181	-118.38219	PV1, rooftop installation 12kW AC system.(38) SPR-327NE-WHT-D(2) SB6000TL-US*Derate Main Breaker from 200A to 150A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47547	18041-30000-07180	2029-2049 CENTURY PARK EAST Level D-Corridor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	PIN	34.05864553	-118.41292403	Plan check for title 24 only existing corridor Level D.Total area: 1975 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47548	16041-20000-18033	10777 W SANTA MONICA BLVD	90025	5	129B153    23	4325030006	[Q]RD1.5-1-O, [Q]RD1.5-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.05147	-118.43332	PLANCHECK FOR T24 ENERGY. LIGHTING T.I. FOR LA TEMPLE GARDEN ROOM . 3027 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47549	19041-10000-10252	5401 W HIGHLIGHT PL	90016	10	120B177   735	5047014900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.02341	-118.36456	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47550	16041-10000-09061	4627 N MARY ELLEN AVE	91423	4	168B157   684	2360024023	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.15481	-118.41936	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER AND OPTIMIZERS. (47) MODULES AND (1) 11.4KW- INVERTER. TOTAL SYSTEM SIZE IS 11.4KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47551	14041-20000-23505	9020 N RESEDA BLVD Ste 103	91324	12	195B125    51	2769001028	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.2346	-118.53587	TI to drive thru restaurant (Urbane Cafe).  Plan check for power and energy per applicant request.   2013 Building Energy Efficiency Standards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47552	11041-20000-20831	700 N FAIRFAX AVE #A	90046	5	141B177   515	5527011005	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	09/29/2011 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.0841	-118.36119	First time tenant (Suite #A). Tenant loads were checked on core & shell. Plan check T24 Energy only, no change to power from core & shell. Permit for lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47553	13041-10000-35105	4433 S ALAMEDA ST BLDG A1	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.00295	-118.23924	"T24 PART 6 ENERGY FOR (E) 9,860 SQ FT COMMERCIAL SPACE BUILDING ""AA"" OR ""A1"".  RETRO-FITTING 4' FLUORESCENT LIGHT FIXTURES WITH NEW F54T5HO LAMPS ONLY.  SCOPE OF WORK < 400A.  PERMIT IS EXISTING UNDER 11041-10001-21647.  NO NEW/MOVED WIRING PER APPLICANT, INSTALLATION NOT SUBJECT TO LIGHTING CONTROL REQUIREMENTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47554	12041-20001-18799	147 N LARCHMONT BLVD	90004	4	138B189   757	5515019020	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Approved	12/18/2012 12:00:00 AM	ADDRESS	34.07437	-118.32384	energy plan check gym. place	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47555	14041-20000-05317	6329 N AGNES AVE	91606	2	177B165    36	2334003045	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Expired	04/05/2016 12:00:00 AM	ADDRESS	34.18575	-118.39555	Roof mounted PV system with 3.5KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47556	11041-20000-16779	2000 S AVENUE OF THE STARS suite 550N	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	energy plan checck suite 550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47557	18041-10001-22758	653 1/2 E MILWOOD AVE	90291	11	108B145   951	4241005024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	PIN	33.99226654	-118.46398708	Expedite per applicant request.(((Plan check for a PV1 5.2KW roof mounted system with (14) modules and (1) 5.2KW inverter interconnecting through a new load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47558	14041-10000-17454	523 W 6TH ST # 430	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Corrections Issued	07/03/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	PC FOR ENERGY ONLY. HIGH RISE. OFFICE.TOTAL AREA 5320 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47559	13041-10000-34161	1615 E MAURETANIA ST	90744	15	036B213   562	7425024029	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	33.79041	-118.24411	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 8661 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47560	12041-20001-27052	4253 N COLDWATER CANYON AVE	91604	2	165B161  1098	2375019041	C1.5-1VL, RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.1469	-118.414	Changes to approved set of plans. change from flourescent to LEDs. Changes to indoor lighting only.Plan check for energy and emergency lighting. two-story office. 3697 indoor sqft, 3127 outdoor sqft. Permit has already been pulled under 12041-20000-23638.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47561	11041-20000-01619	5219 N CRANER AVE	91601	4	171B173   519	2416004023	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	ADDRESS	34.1655	-118.36924	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT TO CONVERT EXISTING MANUFACTURING BLDG TO TV PRODUCTION OFFICES. SUBJECT FOR GREEN BUILDING COMPLIANCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47562	17041-10001-19827	2780 N LA CASTANA DR	90046	4	156B177   671	5570002029	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			Reviewed by Supervisor	06/20/2017 12:00:00 AM	ADDRESS	34.12103	-118.35768	Expedite fees only.       Installation of new roof mounted solar PV system on existing single family dwelling with battery back up system.  New Solaredge SE 7600A inverter with 27 SolarCity Standard SC325 modules and 1 Tesla AC powerwall 5.8 kVA / 13 kWH battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47563	14041-20000-18314	21308 W NASHVILLE ST	91311	12	210B105   187	2706032024	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.26892	-118.5959	PV1.  Install roof-mounted solar array on SFD. System size: 10kW.(1) IG Plus Advanced 10.0-1 UNI transformered inverter(30) SunPower SPR-327NE-WHT-D pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47564	17041-10000-17339	3201 S HOOVER ST STE 8-E2	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Issued	07/12/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	FIRST TIME TI TO RETAIL UNIT. PC FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47565	18041-10000-07997	929 W JEFFERSON BLVD Bldg #6-Suite 1630	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.02454	-118.28546	PC FOR POWER AND ENERGY FOR FIRST TIME TENANT RESTAURANT IN USC. SCOPE INCLUDES NEW EQUIPMENT, PANELS, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 824 SQ. FTB#18016-10000-03113	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47566	16041-10001-20713	18909 W KINZIE ST	91324	12	201B121   283	2762039005	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.24831	-118.54527	08/02/16Changes to an approved set of plans. Changes include relocating the solar modules on the roof-layout, converting two solar strings into three solar strings on the single line diagram, changing the module type from Canadian solar CS6P-255P to Canadian solar CS6K-275M, and changing the microinverters from Enphase M215-60-2ll-s2x-ig to Enphase M250-60-2ll-s22. New system size is 9.35KWdc / 8.16KWac (((((PV SYSTEM WITH 34 MODULES, MICROINVERTER SYSTEM. USING ENPHASE M215. PV SYSTEM WITH ROOF TOP MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47567	19041-20000-16701	22135 W ROSCOE BLVD LOT #43	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	pv1install roof mounted pv system sized 2.0KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47568	19041-20000-06316	3015 S HOOVER ST STE 186	90007	9	121-5A201 147	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	07/13/2020 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.02712	-118.28423	T24 PLAN CHECK FOR ENERGY ONLY. ADDING NEW LIGHTING, NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS. TOTAL SQUARE FOOTAGE = 1670 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47569	17041-20000-14321	5009 W MELROSE AVE	90038	13	141B193   569	5535017007	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.08365	-118.30964	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT TO (E) RESTAURANT. 698 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47570	19041-10000-38594	21300 W ROSCOE BLVD	91304	3	192B105   610	2109001003	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.21955	-118.59643	PC FOR FIRE ALARM SYSTEM. SYSTEM INCLUDES (1)FACP AND (53) DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47571	12041-10000-01738	6604 N FARRALONE AVE	91303	3	180B101   384	2139016004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2012 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.19025	-118.61008	New 6.21kw rooftop photovoltaic system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47572	19041-30000-52090	1801 W OLYMPIC BLVD 4TH FLOOR	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM			PC Info Complete	12/17/2019 12:00:00 AM	ADDRESS	34.05046	-118.27663	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 590 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47573	16041-10000-17522	1840 S CENTURY PARK EAST 2nd Flr	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI: TENANT IMPROVEMENT ON (E) OFFICE  2ND FLOOR.  NEW CONNECTED LOAD LESS THAN 400A. PC FOR T-24 ONLY. TOTAL AREA: 14,764 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47574	18041-20000-40443	5005 N SANLO PL	91364	3	168B113    25	2166038013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.16056	-118.57508	Plan check for PV roof mounted system and energy storage system, PV system size: 11.23KW AC CEC with 37 PV Modules and 37 Microinverters, Tesla Power Wall 2.0 13.5KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47575	17041-20001-45713	15040 W OXNARD ST	91411	4	177B145   482	2243021004	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.17912	-118.461	01/26/2018  Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from warehouse to dance academy/tenant improvement. Total lighting area = 9,417 sq. ft.Note: Building application has been issued under 17016-20000-23233*****Previous Work Description*****MOVE SURFACE MOUNT PLUGS INTO NEW WALLS AND REPLACE SWITCHES.  NO LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47576	13041-10000-09845	1501 W L ST	90744	15	033B201    66	7412010903	OS-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	33.78614	-118.28349	PARKING LOT FOR RECREATIONAL PARK. OUT DOOR LIGIHTING, OLTG. TOTAL AREA 160000 SQ FT.. per supervisor review pc ok.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47577	10041-10000-14772	1420 N COIL AVE	90744	15	036B213    16	7426029007	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	03/23/2011 12:00:00 AM	ADDRESS	33.79347	-118.24241	ROOF-MOUNTED 1.5MW PHOTOVOLTAIC SYSTEM DIVIDE INTO A 500KW AND A 1.0 MW  PV INSTALLATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47578	11041-10000-06549	6440 W HOLLYWOOD BLVD	90028	13	148-5A187 178	5546007001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			Corrections Issued	04/01/2011 12:00:00 AM	ADDRESS	34.10143	-118.33085	alterations in existing commercial spaceplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47579	10041-10000-01363	711 E DUCOMMUN ST	90012	14	130-5A217 233	5173017006	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM			PC Approved	01/26/2010 12:00:00 AM	ADDRESS	34.05203	-118.23277	INSTALL (1) SUBPANEL AND (4) CIRCUITS FOR MISC. RECEPTACLES.  TO INCLUDE REPLACEMENT OF LIGHTS UNDER EXISTING CIRCUITS. plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47580	08041-10001-23883	10445 W WILSHIRE BLVD 1-109	90024	5	135B157   207	4360029***	[Q]R5-3	West Los Angeles	Westwood			2651.00	Electrical	Electrical	Public Safety Only			02/01/2010 12:00:00 AM			PC Approved	02/01/2010 12:00:00 AM	ADDRESS	34.06606	-118.43087	Fire alarm system replacement and upgrade for a high rise residential building, some devices are existing, all panels are new.    (((((((((()))))))))  Add-on   (3) sheets to already approved set of plans, add (1) panel and (1) aux panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47581	15041-10000-07441	6250 W HOLLYWOOD BLVD	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM			PC Info Complete	09/23/2016 12:00:00 AM	ADDRESS	34.10133	-118.32547	Tenant improvement of existing retail space for bike membership storage.  Plan check for energy under 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47582	17041-20000-43368	635 W DOWNEY WAY FLR 2, 5	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.01874	-118.28387	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT FOR 5TH FLOOR. . AREA OF ALTERATION OCCURS ON 2ND FLR COVERING 220 SF AND 5TH FLR 9300 SFBUILDING P # 17016-10000-34533	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47583	18041-20000-28670	1380 W ROLLAND CURTIS PL	90062	8	117B193  1014	5036014020	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.01634	-118.30259	Plan check for PV roof mounted system, system size: 5.76kW with 18 pv modules and 18 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47584	15041-10004-05395	3201 S HOOVER ST	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			Reviewed by Supervisor	05/18/2016 12:00:00 AM	ADDRESS	34.02548	-118.28442	M.Z.  5-5-16  there are 6 buildings  name s are B-1   B4     B6      B7     B8    B9  .   to check the Z value on unit substation   and fault study. All changes are under delta-29 only.(((Full plan check for a central plant in a single story building (USC village, bld #1). Scope of work includes medium voltage, and all work is under building #1 only. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47585	18041-10000-07287	2139 S CAMDEN AVE	90025	5	126B153   609	4322018013	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Issued	03/06/2018 12:00:00 AM	ADDRESS	34.04151	-118.4366	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 9.43KWDC/ 7.6KWACSCOPE INCLUDES 29MODULES WITH OPTIMIZER AND CENTRAL INVERTER.(ESS UNDER SUPP).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47586	15041-20001-22534	3616 S TROUSDALE PKWY Room#145	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.01983	-118.28534	Supplemental 1, changing to an approved set: Adding women restroom and storage room. PC for Energy only. Total area increased from 2,456sq.ft to 2,692sq.ft.Permit under 15041-20000-22534((Plan check for Title 24 only in USC Allan Hancock Foundation (AHF) existing space. Total indoor area:2456sqft))WOMEN'S RESTROOM, STORAGE ROOM- B5A AND B5B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47587	14041-10000-26406	4454 N VENTURA CANYON AVE	91423	4	165B157   132	2360004***	(Q)R3-1, R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Apartment			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.15197	-118.42946	New fire alarm system in apartment building including (1) control device, (1) communication panel, (1) fire alarm panel, and  (31) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47588	19041-10000-34089	1900 E 15TH ST	90021	14	120A215   167	5167019056	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.02272	-118.2367	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47589	12041-10000-12255	659 S FLOWER ST	90017	14	129A209    49	5144008009	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	ADDRESS	34.04907	-118.2587	T.I. to an existing restaurant.  Load is less than 400A,  occupancy load is 38, per applicant.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47590	14041-20000-17466	6030 S SEABLUFF DR	90094	11	102B157   324	4211021039	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	33.97298	-118.42231	NEW APPARTMENT BUILDING PLAN CHECK FOR POWER AND ENERGY.  72 UNITS, 5 STORIES ABOVE GRADE AND  ONE UNDERGROUND LEVEL PARKING LOT. HAZARDOUS LOCATION, METHANE ZONE. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 CA ENERGY CODE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47591	15041-20000-12645	714 E DUCOMMUN ST	90012	14	130-5A217 270	5173016001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.05179	-118.23265	Plan check for power only.  Service upgrade to 600 A for existing commercial space.  Project is located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47592	14041-10000-20252	888 W 6TH ST	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.05062	-118.25846	ADDITIOIN TO EXISTING FIRE ALARM SYSTEM. 241 DEVICES, 2 PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47593	19041-20000-32611	1258 W 21ST ST	90731	15	012B193  1161	7460021018	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2973.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	33.72532	-118.30482	Plan check for PV install in to existing PV roof mounted system. New PV system size intall is 2.17 KW with 7 microinverters and 7 microinvergers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47594	19041-10000-31825	747 E 59TH ST	90001	9	105B205    17	6007002028	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	33.9873	-118.26122	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47595	16041-10000-38249	11766 W WILSHIRE BLVD 18TH FL	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	02/04/2017 12:00:00 AM	ADDRESS	34.04804	-118.46227	18TH FLOOR TI. PC FOR T24 ENERGY ONLY. NEW LIGHTING. OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47596	15041-10000-06077	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.06725	-118.41704	TI TO AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  REPLACING SWITCHBOARDS RECONNECTING TO EXISTING LOADS AND ADDING NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47597	12041-20000-05849	23801 W OXNARD ST	91367	3	177B089   604	2045013027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2012 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.17962	-118.64466	New roof mounted P.V. system (8.64KW) with microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47598	12041-20000-26925	7500 N GLENOAKS BLVD FAB LAB 2	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.02	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.20696	-118.3417	Install new fire alarm control panel, pull stations and hornstrobes and reconnect existing fire alarm circuit to the new panel.  For FAB LAB2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47599	18041-10000-46440	817 S TREMAINE AVE	90005	4	132B185   162	5090001002	R1V3-RG	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.06026	-118.33622	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 44 MODULES (Q.PLUS L .G4.2 325), 22 MICROINVERTERS (CP-720-60-72-208/240-MC4) AND COMBINER BOXES. SYSTEM SIZE IS 14.30 KWDC 15.8KWAC.PERMIT FEE IS $ 0 DUE TO AB 1441	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47600	17041-20003-38045	1015 S ORANGE GROVE AVE	90019	10	132B177   718	5086001053	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.0575	-118.36311	07-31-2018 Changes to an approved set of plans, changes include relocate inverter to roof. changes has been clouded as delta 1. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47601	17041-20000-22681	13478 W EGBERT ST	91342	7	228B157    60	2503016011	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	34.32548	-118.42682	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47602	19041-20000-53581	4450 N GAYLE DR	91356	3	168B121   584	2177008013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.15265	-118.54934	Plan check for PV roof mounted system, PV system size: 16.5KW with 50 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47603	18041-10001-20340	6505 S ESPLANADE #3	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	33.96159	-118.45071	3 OF 5******EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47604	16041-20000-15265	12326 W RIVERSIDE DR	91607	2	168B165   537	2356034011	R1-1-RIO, R3-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.15745	-118.40171	Plan check for Title 24 only. Project site is an existing commercial building (classroom). Project scope is a water damage repair. Total lighting area = 467 sq. ft.Note: Building application has been generated under 16016-20000-09432	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47605	14041-20000-01440	672 1/2 E INDIANA AVE	90291	11	111B145  1312	4239008019	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	33.99723	-118.46715	PV1 TWO FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC. THIS IS SECOND SYSTEM TO BE ON SAME INTERCONNECTION AS THE ORIGINAL ADDRESS RANGE. INTERCONNECTION IS 400A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47606	14041-10000-05201	4129 N FARMDALE AVE	91604	2	162B169   140	2368022004	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.14344	-118.38128	PV1, Install 7.5 kW DC roof-mounted solar array on a 2-story home, interconnect with EXISTING service panel. (1)Transformerless inverter: Solaredge SE 6000A-US. (30) Modules: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47607	12041-10000-20445	1888 S CENTURY PARK EAST	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.06104	-118.41402	TI in a Bank. New panels, x-former, and ckts. EPS is for power & T24.3RD FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47608	15041-10000-01302	21650 W OXNARD ST 18TH FL	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	ALTERATIONS IN EXISTING OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47609	16041-10000-36735	4853 W GLENCAIRN ROAD	90027	4	153B197   310	5588012028	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	01/28/2017 12:00:00 AM	ADDRESS	34.1142	-118.29647	PERMIT FEES ARE LIMITED DUE TO SENATE BILL 1222PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.6KWdc / 11.2KWac.(35)AC MODULES-SPR-X22-360-C-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47610	19041-20000-44902	15424 W VOSE ST	91406	6	183B145   294	2222034007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.19834	-118.46938	PV1. INSTALL 3.72 KW DC PV SYSTEM WITH (12) MODULES/OPTIMIZERS AND (1) INVERTER(SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47611	18041-10000-48938	3054 W PICO BLVD	90006	10	129B193  1324	5074001006	C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.04702	-118.30782	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47612	10041-20000-14976	707 N RIDGEWOOD PL	90038	13	141B189   293	5535002024	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			08/02/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	11/10/2010 12:00:00 AM	ADDRESS	34.08378	-118.31476	Plan check for power. Existing service. New 800A board supplying commercial section and 400A section for apartment section. New 400A Panel A for compliance of point of connection for PV system (150A+225A supplying OCPD). No new load. PV sytem on seperate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47613	14041-10000-20785	750 E 12TH ST #2	90021	14	123A211    50	5132012032	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.03273	-118.25185	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47614	17041-10000-07274	1028 W E ST B 10, LOT3	90744	15	030B201   686	7417011900		Harbor				2949.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM				INSTALLATION OF A NEW FA SYSTEM FOR A 3-FLOOR APARTMENT BUILDING. 2 FA PANELS AND 39 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47615	14041-20000-20686	8139 N CORBIN AVE	91306	3	189B117    78	2106014001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.21779	-118.56245	Standard Plan: 5KW PV1 roof-mounted system including: (20) Canadian Solar CS6P-250PX modules and one PVI-3.6-TL transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47616	11041-10000-03187	6353 W HOLLYWOOD BLVD # 204	90028	13	148-5A187 153	5546005014	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM			PC Approved	02/17/2011 12:00:00 AM	ADDRESS	34.10177	-118.32842	TI IN OFFICES; NO CHANGES  OF THE EMERGENCY LIGHTING AND EXIT CHANGESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47617	17041-10000-14813	7541 N BECK AVE	91605	2	186B169   335	2316012041	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.20776	-118.38355	PC FOR PV SYSTEM ROOF MOUNTED 5KW AC 20 MODULES TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47618	14041-20000-24065	11761 N ANDASOL AVE	91344	12	213B129    36	2601041052	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Expired	09/30/2016 12:00:00 AM	ADDRESS	34.2843	-118.51406	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.2kW.(2) Power-One Aurora PVI-3.6-OUTD-S-US-Z-A transformerless inverter(40) Trina Solar TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47619	17041-10000-39823	1491 W O'FARRELL ST	90732	15	018B193   375	7452002001	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	33.74604	-118.30845	Replace Outdoor existing fixtures with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47620	15041-20000-21814	15037 W ROXFORD ST #6	91342	7	228B145   805	2502002068	(Q)C1-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Expired	08/03/2017 12:00:00 AM	ADDRESS	34.32186	-118.4606	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47621	12041-20000-24418	189 S THE GROVE DR 1st floor-Valet	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	Plan check for energy and emergency lighting. 13437sqft. Indoor parking structure. Emergency is powered by a generator. Private High End Shopping Area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47622	12041-10000-27655	12760 W MILLENNIUM A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	Plan check for new methane mitigation system for Building A (retail and residential) with subterranean parking	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47623	10041-10000-20044	10341 S GRAHAM AVE	90002	15	090A213   191	6065023906	PF-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Expired	04/08/2014 12:00:00 AM	ADDRESS	33.94212	-118.24274	New 4 screens cinema building, and business offices.  Interior and exterior T24 energy cmopiance.  The DWP is requireing the 3 services 600 amperes , 480/277 3 Phase 4 wire. to account for transformer loading.   Contact at DWP is Alex Salvador,  (213) 367-8023.  A letter from the DWP requiring 3 services at the site will be submitted to plan check for review within 30 days.  Approximately August the 14, 2011  A variance to separte the fire warning system, and multiple service at the building was submitted on July 14, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47624	18041-20000-19193	1926 E 7TH PL	90021	14	124-5A217 332	5166017005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.03343	-118.23298	Change of use from warehouse to theater and 400A service upgrade.  Place of assembly exceeding 100 occupants.  Building permit under 17016-10000-03724.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47625	14041-10000-04979	4208 W DUNDEE DR	90027	4	154-5A201 457	5592018031	RS-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.11722	-118.28397	PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE5000A-US-ZB-U(18) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47626	19041-30000-17480	7501 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	07/07/2020 12:00:00 AM	ADDRESS	34.20692	-118.49233	Plan check for a PV2 roof-mounted PV system. System is feed-in tariff. System size is 908 kW DC / 823.72 kW AC-CEC and consists of (24) inverters, (6) load centers, and (2,270) modules.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47627	17041-10000-04962	2844 E 2ND ST	90033	14	126A225   296	5180022900	OS-1XL	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM			PC Approved	02/15/2017 12:00:00 AM	ADDRESS	34.03905	-118.20448	PC FOR ENERGY. T.I. TO EXISTING RESTROOM FOR DISABLED ACCESS, TOTAL AREA 231 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47628	19041-20000-25566	9006 N SEPULVEDA BLVD	91343	7	195B145   654	2654004052	[Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Closed	07/24/2020 12:00:00 AM	ADDRESS	34.23461	-118.46688	ti to an existing commercial building.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47629	19041-20000-51398	129 N ROCKINGHAM AVE	90049	11	132B137   318	4406001020	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	07/02/2020 12:00:00 AM		Permit Finaled	05/16/2022 12:00:00 AM	ADDRESS	34.05852	-118.49146	PV1. Install 17.3 kW roof mounted PV system. (60) modules with (2) 7.7 kW rated inverters.$0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47630	17041-20002-31627	2322 S DUXBURY CIR	90034	5	126B165   488	4309014015	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM			PC Approved	08/20/2018 12:00:00 AM	ADDRESS	34.04189	-118.39598	8/20/2018changes to an approved set of plans.  changes to point of connection and update plans to reflect field conditions.   this is plan check only.  (((permit fee $0.00 by state senate bill no.1222PV1.  Install 13.37 kW AC CEC roof mounted grid tied PV system.  (56) modules with microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47631	10041-10000-15411	14731 W RAYEN ST	91402	7	195B149   247	2651012028	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM	04/28/2011 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.23197	-118.45487	New 42 unit apartment building for Affordable housing with 3 stories over subterranean garage.  New service, panels, and branch circuits.  Plan check for power and energy. Plan chk fees may be needed to be adjusted.  To comply w/ dept. order dated 09-03-09. Permit will expire 30 days from issuance date.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47632	10041-30000-12589	165 S LA BREA AVE	90036	5	138B181  1156	5513019004	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	09/20/2010 12:00:00 AM	ADDRESS	34.07174	-118.34423	TI in an existing commercial space. Existing 400 amp service core and shell. Complete Electrical Plan Check may be required subject to field inspection. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47633	12041-10000-19012	10916 W LINDBROOK DR	90024	5	132B153   323	4363023034	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.05938	-118.44489	New Restaraunt in an existing space.   Load is greater than 400 Amps per applicant.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47634	14041-20001-24800	7000 S HOOVER ST Unit #5	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	expedite feesNew roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #5.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47635	09041-10001-24028	8640 W 3RD ST	90048	5	138B169   564	4334011021	C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.07338	-118.38114	REVISIONS TO PERMITTED SET OF PLANS: SERVICE IS 1000A NOT 800A; NEW PANEL BOARD FOR FUTURE X-RAY EQUIPMENT NEW CIRCUITS; SERVICE FROM NEARER POWER POLEPLANS ARE AS-BUILT SET OF PLANS(((((((((New 3-story Medical building.  Permit is for new service, new switchboard, new panels, new ckts, new equipment.  T-24 was not included in original submittal.  P/C is for Power and Energy.  A control panel shall be provided to allow no more than 2 car jacks on panel HJ to operate at the same time.  This is called out in Specific note 8 on sheet E-3.  Any changes on the system will require replan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47636	15041-20000-28568	3498 N ALANA DR	91403	5	159B141    45	2280017043	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.13547	-118.47963	PV1. Install roof mounted PV system sized 15.4 kW. Interconnected with main service panel.(56) Kyocera KD 265 Modules(2) SMA SB7700 TL InvertersNote: Fee is $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47637	19041-20000-38111	7668 W LE BERTHON ST	91042	7	207B197    51	2552025038	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.26791	-118.29966	PV1.  Install 5.22 kW DC / 4 kW AC roof mounted grid tied PV system.  (18) modules with 4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47638	17041-10000-34181	11050 W SANTA MONICA BLVD 3RD FLR	90025	5	129B153   810	4323019052	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.04783	-118.44275	Energy plan check for a partial office T.I located in the 3rd floor of a commerical building . Total area is 2954 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47639	18041-10000-35941	425 S PACIFIC AVE	90731	15	015B197    95	7451027021	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	33.74001	-118.28807	FULL PLAN CHECK FOR REMODELING AN EXISTING BUILDING INTO A PEDIATRIC CLINIC FOR OSHPD 3 CERTIFICATION.  SCOPE INCLUDES A NEW 800-AMP SERVICE, (5) PANELS AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47640	15041-10000-19106	1440 S SEPULVEDA BLVD	90025	5	129B149    38	4324016094	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.05107	-118.44699	PC FOR ENERGY ONLY. TI FOR OFFICE. FOX NETWORK. TOTAL AREA 10954 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47641	17041-10000-41429	5271 W SANCHEZ DR	90008	10	117B177   348	5029005016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Issued	11/15/2017 12:00:00 AM	ADDRESS	34.01545	-118.35992	PC FOR ROOF  MOUNTED PV ON SLD. SYSTEM SIZE 10.0KWAC / 11.52 KWDCSCOPE INCLUDES 36 MODULES WITH OPTIMIZERS. CENTERFED PANEL VARIANCE HAS BEEN SUBMITTED UNDER 17041-10000-37904 (OLDER ELECTRICAL DESIGN)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47642	18041-20000-44035	1476 E 92ND ST	90002	15	094-5A211  45	6048001017	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Expired	10/26/2023 12:00:00 AM	PIN	33.95297022	-118.24797128	PV1.  Install roof mounted PV system sized 5 kW AC interconnected with (N) subpanel.  (18) modules with 5 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47643	11041-10000-02292	10500 N SHERMAN GROVE AVE 1-71	91040	2	207B189  1086	2555033029	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	Apartment			02/04/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	05/02/2011 12:00:00 AM	ADDRESS	34.26005	-118.31993	INSTALLATION OF NEW FIRE SYSTEM WITH 118 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47644	11041-10000-11370	8655 S LINCOLN BLVD	90045	11	096B161   737	4119026038	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	06/08/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	33.95859	-118.41793	T.I.  Remodeling of light fixtures on a single story store (Centinela Feed and Pet Supply).  Plan check is for Energy and Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47645	15041-10000-42245	7101 N OSO AVE #15	91306	3	183B113   925	2136007***	(Q)RD6-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.19918	-118.57564	PV2. THIS IS SINGLE FAMILY DWELLING LOCATED ON TOWN HOUSING TRACK. THIS IS PV SYSTEM TOTAL SIZE 5.7KW AC UISNG TOTAL OF 24 MODULES. USING MICROINVERTER SYSTEM WITH ENPHASE M250.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47646	19041-20000-34473	10983 W BLUFFSIDE DR	91604	2	162B173   285	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	09/02/2022 12:00:00 AM	ADDRESS	34.1418	-118.36941	PV2 BUILDING #6 (N) 21.4 KW AC/23.76 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (66) PV MODULES WITH (1) 6 KW INVERTER, (2) 7.7 KW INVERTER, AND A 200A PANEL BOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47647	19041-20000-53589	1955 N TAMARIND AVE 1-24	90068	4	150A191    51	5586014***	RD1.5-1XL	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	10/02/2020 12:00:00 AM	ADDRESS	34.10669	-118.31948	Replace the existing old Fire Alarm Panel with a new one with 13 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47648	14041-20000-12541	15233 W VENTURA BLVD 210	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.1538	-118.46502	Plan check for the Title 24 lighting  on the office of 203 and 204 in  suite 210.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47649	12041-20000-22048	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/17/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	02/04/2013 12:00:00 AM	ADDRESS	34.06371	-118.3703	Tenant Improvement of 15th floor & partial 14th floor. (Removing and adding load. Connected load over 400 Amps)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47650	16041-20000-20535	1545 W 36TH PL	90018	8	120B193  1362	5041017015	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	34.02197	-118.30445	Plan check for PV roof mounted system. System size: 1.75kW with 7 microinverter and 7 modules. Note: Rent control prevent applicant from doing online	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47651	12041-10000-00986	3650 W MARTIN LUTHER KING, JR BLVD #101-A	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	New restaurant, change of use from Retail to Restaurant.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47652	10041-10000-20779	4160 S LINCOLN BLVD	90292	11	105B153    34	4230001006	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	33.98707	-118.44434	T-24 and emergency lighting plan check for remoded space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47653	18041-10000-39496	3540 W WILSHIRE BLVD	90010	10	132B193    47	5094001002	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Permit Closed	02/23/2022 12:00:00 AM	ADDRESS	34.06157	-118.30171	PC FOR NEW FIRE ALARM IN HIGH RISE BUILDING  LIVE-WORK (13 STORIES). SCOPE INCLUDES 595 DEVICES WITH 6 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47654	15041-10000-16337	8546 N REMICK AVE	91352	6	192B165   118	2634022009	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.22597	-118.4001	PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: TRINA SOLAR 225-WATT(22) MICRO INVERTER: ENPHASE M215-60-2LL-S22-IG	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47655	15041-10000-12730	3316 W BEVERLY BLVD	90004	13	138A201   136	5501018001	C2-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Closed	11/13/2017 12:00:00 AM	ADDRESS	34.073	-118.28499	Full plan check for a mix used of 5-story, 40-units commercial and apartment building.  Main scope includes a 2000-Amp 208/120V 3phase 4-wire service (14) typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47656	13041-10000-18850	13567 N FELLOWS AVE	91342	7	228B145   421	2502004008	RA-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.31874	-118.46111	ROOF-MOUNTED PV1, SUPPLEMENTAL TO PERMIT #13041-20000-16521(EXPRESS PERMIT): ADDDING PLAN CHECK, 1 COMBINER BOX AND 33 MODULES AND 3 STRINGS.SYSTEM SIZED AT 8.25KW DC. INVERTER # FRONIUS # IG PLUS 7.5. MODULE # CANADIAN SOLAR CS6P-250PX-BFREFERENCING TO: EXPRESS PERMIT # 13041-20K-16521 SUPPLMENTALPERMIT #13041-10001-16521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47657	19041-20000-31361	4971 S CENTINELA AVE #1-15	90066	11	105B161   171	4221023034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	Apartment			08/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/08/2021 12:00:00 AM	ADDRESS	33.98726	-118.4165	PLAN CHECK FOR NEW 1200A SERVICE, (1) 400A MAIN PANEL, (1) 800A MAIN PANEL, (17) SUB PANELS, (438) BRANCH CIRCUITS, AND (36) EQUIPMENT LOADS. T24 INCLUDED. TOTAL EFFECTED AREA 18,225 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47658	19041-20001-53510	3613 N DIXIE CANYON AVE	91423	4	162B157   635	2386009024	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM			PC Approved	01/17/2020 12:00:00 AM	ADDRESS	34.14	-118.42676	PV1. INSTALL 15.84 KW DC ROOFMOUNTED PV SYSTEM WITH (48) MODULES AND MICROINVERTERS(ENPHASE IQ7X-96-2)(TO BE ASSIGNED IN VN PER APPLICANT REQUEST)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47659	16041-30000-35027	3400 W SAN FERNANDO ROAD	90065	13	153B209    81	5458003006	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.11904	-118.25037	Title 24 plan check only.  Remove HID fixtures and replace with new LED fixtures.  Total area = 9,600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47660	13041-10000-09450	16356 W TULSA ST	91344	12	207B137    67	2680020020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.26787	-118.48869	PV1 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 5.39 KW. TRANSFORMERLESS. 22 MODULES AND 1 INVERTER. [INVERTER: SOLAR EDGE SE5000A-US] [PV MODULE: TRINA SOLAR TSM-245PC05/PA05.18].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47661	12041-20000-07501	12025 E WATERFRONT DR	90094	11	105B165   915	4211011031	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM			PC Approved	04/02/2012 12:00:00 AM	PIN	33.98296022	-118.40473838	Tenant improvement. 3rd floor of commercial high rise. Plan check for energy and emergency lighting. 26,341 conditioned sqft. USC Playa Vista.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47662	15041-20000-33626	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011065	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	33.98179	-118.40283	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 2980.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47663	16041-20000-41165	5670 W WILSHIRE BLVD Ste 1900	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI to (E) commercial office space in commercial highrise building.  1564 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47664	14041-20000-22608	1212 N LA COLLINA DR	90069	4	144B165   175	4392016032	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.09283	-118.39552	Remodel of (E) 4060 square feet single family dwelling.  Rewiring of house and new 600A service and service equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47665	11041-10000-23606	12100 W OLYMPIC BLVD Ste 470	90064	11	123B149   575	4259025010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.03215	-118.45396	T.I. to an existing office building.  PLAN CHECK ONLY for ENERGY with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47666	15041-20000-00711	6036 N RHODES AVE	91606	2	177B165   589	2333014019	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.18059	-118.40289	PV1 SFD. TOTAL SYSTEM SIZE 8.8KW AC USING 2 TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. TOTAL OF 30 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47667	17041-20000-02958	11900 N EL ORO WAY	91344	12	216B133   407	2606024006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.28762	-118.50311	permit fee $3.11 by state senate bill no. 1222Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 150A. 12kW ungrounded system (6kW*2). (44) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47668	11041-10001-20627	1048-1058 S DOREEN PL BLDG 3	90291	11	111B149   684	4243002068	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/11/2012 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Expired	02/04/2014 12:00:00 AM	ADDRESS	33.99968	-118.45883	REPAIRS & HISTORICAL REHABILITATION  / TI OF 22 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.(((((((((((((((((((((((((((((((((((( addition of 6 new ckts for dettached garage,  changes to previously approved set. )))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47669	13041-20000-15409	4319 N SHADYGLADE AVE	91604	2	165B165   587	2367002016	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.14916	-118.40203	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. OWNER BUILDER PROJECT. 32 MODULES AND 2 INVERTERS. TOTAL SYSTEM SIZE: 9.6KW WITH 2 5KW INVERTERS. (((FIELD VERIFY THAT LOAD CENTER CONTAINS NO SPACES FOR ADDITIONAL LOADS, 4 CIRCUIT LOAD CENTER ONLY)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47670	13041-10000-06695	3800 W MT LEE DR	90068	4	159B189    10	5581010900	OS-1XL	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.13546	-118.3184	(Francis) RENOVATION OF DATA/ TELECOMMUNICATIONS CENTER ON MOUNT LEE. BUILDING IS NEEDED FOR 24 HOUR OPPERATION AND WORK WILL BE COMPLETED IN PHASES TO KEEP THE SYSTEM OPEN. SCOPE OF WORK INCLUDES UPGRADE OF MAJOR POWER EQUIPMENT AND INCREASE THE RELIABILITY. NO NEW LOADS. PC FOR POWER SYSTEM ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47671	18041-20000-19561	2539 S PROSSER AVE	90064	5	126B161   165	4318010036	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.04108	-118.41833	PV1.  Install 6.21 kW roof mounted grid tied PV system.  (18) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47672	19041-20000-06173	1738 N NICHOLS CANYON ROAD	90046	4	147B177   117	5551009013	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	03/16/2019 12:00:00 AM	ADDRESS	34.10276	-118.35843	Plan check for a PV1 roof-mounted PV system. System size is 7.62 kWdc/6 kWac and consists of (25) micro-inverters, (25) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47673	12041-20001-04660	6614 W HOLLYWOOD BLVD Suite A, B	90028	13	148-5A185 130	5547015013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			PC Approved	08/30/2012 12:00:00 AM	ADDRESS	34.10141	-118.33371	Minor changes to previously approved set of plans. Small changes to indoor and outdoor lighting. Relocation of rooftop equipment. Emergency lighting was left intact.New 600A service, switchboard, and subpanels.  Plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47674	19041-20000-13181	217 S LA BREA AVE	90036	5	138B181  1331	5513022011	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Issued	04/19/2019 12:00:00 AM	ADDRESS	34.07052	-118.34422	Plan check for Title 24 energy only in existing space Tenant improvement  Art Display Area. Total area:4,068 sq ft. B#19016-10000-40537	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47675	19041-10000-15386	1015 S CROCKER ST STE Q26-B	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.0345	-118.2508	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47676	11041-10000-11527	1630 N MAIN ST BLDG 11	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	PIN	34.06623967	-118.22749482	Installation of an exterior  30 KW Photovoltaic sytem.   The modules are installed on the roof  of  buidling 11 as shown on the area plan.  The system is grid tied.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47677	19041-10000-14751	11111 W OLYMPIC BLVD 2nd FLOOR	90064	5	126B153   787	4322025046	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Issued	04/24/2019 12:00:00 AM	ADDRESS	34.0401	-118.43851	T-24 PLAN CHECK FOR A TI TO AN EXISTING OFFICE SPACE (2ND FLOOR). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 2490 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47678	19041-20000-22585	20801 W NORDHOFF ST UNIT C	91311	12	198B109   175	2748037017	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM			PC Info Complete	11/06/2019 12:00:00 AM	ADDRESS	34.23563	-118.5863	New distribution, power, and lighting for existing building supplied by existing 2000A 480Y/277V 3ph-4w service.  Plan check for power and energy.Associated building permit under 19016-20000-22765.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47679	18041-10001-30595	14001 W OSBORNE ST	91331	6	195B153   210	2642031021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.23346	-118.43824	SCOPE OF WORK INCLUDES TENANT BUILD OUT TO PREVIOUSLY APPROVED FIRE ALARM PANEL. ADDITION OF 122 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47680	18041-10000-47406	960 N LA BREA AVE	90038	4	144B181   634	5531015004	(Q)M1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/14/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	07/20/2022 12:00:00 AM	ADDRESS	34.08868	-118.34386	PC FOR A  FA FOR AN EXISTING 5 STORY COMMERCIAL BUILDING. SCOPE INCLUDE 1 FA CONTROL PANEL. 113 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47681	19041-20000-48618	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			PC Info Complete	01/24/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	FULL PLAN CHECK FOR 160 EV CHARGERS, (4) 1000 MDP, (16) 225A PANELS, (2) 125A, AND (4) 300 KVA TRANSFORMERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47682	14041-20000-17637	633 W 5TH ST 22ND FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.05099	-118.25468	INTERIOR TENANT IMPROVEMENTEXISTING OFFICE SPACE. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47683	18041-20001-48466	16841 W OAK VIEW DR	91436	5	168B133   412	2289018018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2019 12:00:00 AM			PC Approved	03/08/2019 12:00:00 AM	PIN	34.15498235	-118.50072065	03-08-2019 Changes to an approved set of plans, changes include point of interconnection of the PV system. All Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47684	12041-10000-12587	111 W PACIFIC COAST HWY C-D	90744	15	036B205  1071	7421022036	[Q]C1.5-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM			PC Approved	07/13/2012 12:00:00 AM	ADDRESS	33.7913	-118.26364	T.I. to an existing retail space.  Load is less than 200A and occupancy load is 63, per applicant.  Change to lighting and new receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47685	10041-10000-20457	1933 S BROADWAY 1ST,5TH-6TH FLRS	90007	9	123A207     2	5126031010	[Q]M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.03006	-118.26696	FULL TENANT IMPROVEMENT ON EACH FLOOR TO CREATE OFFICES, CONFERENCE ROOMS, RESTROOMS, CALL CENTER AND STORAGE ROOMS.  INCLUDES INTERIOR NON-BEARING WALLS, CEILING SYSTEMS, MILLWORK AND FINISHES.  139,140SFNOTE: PLANS FOR CORE /SHELL MUST BE PLAN-CHECKED APPROVED BEFORE  TI WORK CAN BE APPROVED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47686	12041-20000-23816	5462 S CENTINELA AVE	90230	11	105B161   849	4220012021	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	PIN	33.98288217	-118.41052878	Repair fire damage to an existing restaurant.  New panel and lighting.  Load is 163 amps and occupancy load is is 30, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47687	10041-10002-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/19/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	Addition and alteration to the TBIT.  The Core Design Notices in which each sheet  changes are noted. Changes include hand dyers and paper  towel dispensers update  panel schedules change layout of  lighting . new circuits. CDN sheets are attached to plans -	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47688	17041-10000-22475	2374 N EDGEWATER TER	90039	13	148-5A209 473	5439006032	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM			PC Info Complete	07/18/2017 12:00:00 AM	ADDRESS	34.09938	-118.26007	PC for rooftop PV for 13 new modules and optimizers, 1 central inverter, two load centers and one 1 energy storage battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47689	16041-20000-41887	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.23342	-118.3809	Plan check for power only. Upgrade existing commercial garage for maintenance of CNG fueled vehicles. Classified hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47690	19041-20002-20075	2222 E WASHINGTON BLVD	90021	14	118-5A217 138	5167005027	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM			PC Approved	08/01/2019 12:00:00 AM	ADDRESS	34.0188	-118.23256	8/1/2019changes to an approved set of plans.  changes to fault current and AIC ratings per utility.  this is plan check only.  ((((FULL PLAN CHECK FOR CHANGE OF USE FROM WAREHOUSE TO INDUSTRIAL HYDROPONICS. SCOPE OF WORK INCLUDES A NEW 100A PANEL,T24 INCLUDED. TOTAL SQUARE FOOTAGE = 3034 SFB#18016-10000-40841))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47691	13041-20001-03721	1901 S BUNDY DR BLDG 1	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.03497	-118.45709	Changes from previously approved plans.  Change in outdoor lighting control panel only.  *****Previous Description*****1901 S BUNDY DR BUILDING #1.  OUTDOOR LIGHTING AND INDOOR LIGHTING FOR HALLWAY AND RESTROOMS IN EXISTING SINGLE STORY OFFICE BUILDING.  ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47692	07041-10003-27331	5315 N BELLINGHAM AVE	91607	5	171B165   265	2347022015	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.01	Electrical	Electrical	Apartment			07/01/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	09/20/2011 12:00:00 AM	ADDRESS	34.16724	-118.39946	New 3-story 17-unit apartment building+ subterraneam garage. New 120/240 1Ph 3W 1200A service.  EPC: Power and Energy(T-24).PLAN CHK IS FOR AS-BUILT SET OF PLANS; OWNER TO TRANSFER ORIGINAL PERMIT TO NEW CONTRACTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47693	18041-20002-44434	9712 W HEATHER ROAD	90210	4	147B161    16	4352002039	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM			PC Approved	01/04/2019 12:00:00 AM	ADDRESS	34.10286	-118.40782	01-04-0219 Changes to permitted set of plans, changes include change PV Modules manufacturer from Trina mount #TSM-305D05A.18(II) to Hanwha Q-Cells #Q.Peak-G4.1/SC305. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47694	16041-10003-08982	9938 N DEBRA AVE	91343	12	201B137    30	2678015015	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.25138	-118.49043	04/04/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE CLOUDED AREAS. CHANGES INCLUDE THE MODULE LAYOUT. (((PV1 rooftop solar installation 12kW system    (39) SPR327NE-WHT-D     (1) SB7000TL-US   (1) SB5000TL-US   (1) 125A load center)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47695	12041-20000-27907	5712 N TAMPA AVE	91356	3	174B117   168	2156005005	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Expired	12/02/2014 12:00:00 AM	ADDRESS	34.1747	-118.55327	PV-1. Plan check for single family dwelling. 10.56kW system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47696	11041-10001-24370	1042 S FREDERICK ST BLDG 2-1	90291	11	111B145   881	4243003032	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/26/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	33.99935	-118.46048	Lincoln Place Apartment Building Project.  New 2-story apt. building with 8 units. Addition of three E.V system and one sub panel  and mete is added to existing section.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47697	10041-10001-21645	8601 S LINCOLN BLVD #160 & 170	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM			PC Info Complete	12/10/2010 12:00:00 AM	ADDRESS	33.95939	-118.41943	INSTALLATION OF 15 NEW FIRE ALARM DEVICES TO AN EXISTING FIRE ALARM SYSTEM @ T.I. AREA.  (DR. BRUKSCH - STE. #160 AND #170).   <<<<PLAN CHECK ONLY>>>>>   PERMIT WAS ISSUED 10041-10000-21645.   <<<<APPLICANT REQUESTED PLAN CHECK>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47698	10041-10000-06811	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	09/20/2010 12:00:00 AM	ADDRESS	33.9451	-118.37436	title 24 and emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47699	11041-10000-12811	4900 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	10/04/2011 12:00:00 AM		Permit Finaled	02/22/2012 12:00:00 AM	ADDRESS	34.09786	-118.29626	REPLACEMENT OF A 2000A PANEL AND 3 MCC, ONE-FOR-ONE, WITH SAME MANUFACTUERER.  WILL BE INSTALLED IN SAME LOACATION WITH NO NEW LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47700	18041-20001-29001	4827 N FULTON AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			12/05/2018 12:00:00 AM			PC Approved	12/05/2018 12:00:00 AM	ADDRESS	34.15858	-118.42347	10-05-2018 Changes to an approved set of plan. Changes include addtion of 10 relay modules. All Changes has been clouded as delta 1. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47701	17041-10000-46263	10561 N HORSE CREEK AVE	91040	7	207B177   243	2528035015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.26185	-118.36175	Install New PV1 rooftop on an (E) SFD. (30) AC modules SPR-X21-345-S-ACW, system 10.35kW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47702	11041-10000-03478	1303 S WELLESLEY AVE 1-18	90025	11	126B145   577	4267033023	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			02/23/2011 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.04118	-118.46773	FULL PLAN CHECK, TITLE 24, NEW 25 UNIT APARTMENT BUILDING.  4 TYPES OF UNITS.    NEW 1200 A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47703	19041-10000-35105	1215 W WASHINGTON BLVD	90007	1	126A201   156	5135012013	[Q]C2-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.03967	-118.28329	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47704	15041-10000-09098	4401 S CRENSHAW BLVD	90043	8	111B185   131	5013013013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	PIN	34.00326739	-118.33207301	PC FOR TITLE 24 AND TOTAL AREA 399 SQ FT.PERMIT WAS OBTAINED ON 15041-10000-25055 EMERGENCY LIOGHTING ARE EXISTING TO REMAIN. BANK OFFICE, COMMERCIAL TI OF EXISTING BANK FOR NEW OFFICE AND 3 INTERIOR ATM MACHINES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47705	12041-20000-22410	10940 W WILSHIRE BLVD 23rd FLOOR	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.05822	-118.4452	Plan check for energy and emergency lighting. 6366 sqft. MAESA Studio. 23rd Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47706	17041-10001-27969	23516 W CANZONET ST	91367	3	171B093   370	2044019012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM			PC Approved	09/01/2017 12:00:00 AM	ADDRESS	34.16555	-118.63928	PC FOR CHANGES TO APPROVED SET. CHANGES TO REFLECT  RELOCATION OF SUNPOWER METER FROM PV LOAD CENTER TO MAIN HOUSE PANEL. THIS IS PLAN CHECK ONLY!!!8.64 kw solar system (24) AC modules, (1) 100A combiner panel, (1) 60 AC Disconnect, (1) Snnpower monitoring. Roof mounted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47707	14041-20002-28809	3844 N WINFORD DR	91356	3	162B121    67	2177041003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.14043	-118.54927	04-28-2015 Change to approve set of plan. Changes apply to layout of the solar panels only. {{{{{{PV1, INSTALL 13.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(40) MODULES: SPR-X21-345 (2) INVERTERS: FRONIUOS IG PLUS A 6.0-240}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47708	14041-20000-17388	3183 W WILSHIRE BLVD	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.06196	-118.29111	TI to (E) bakery/restaurant space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47709	18041-10000-02727	10374 N VENA AVE	91331	6	204B153    91	2617018016	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.25938	-118.43951	PV1 new roof mounted solar system using a central inverter and power optimizers. (1) 5KWAC and (20) modules with DC optimizeres.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47710	19041-30000-09310	2049 S CENTURY PARK EAST 33rd Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is the 33rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 23,848 sq. ft.Note: Building permit has been issued under 18016-10000-37628	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47711	14041-10000-18112	1447 N DEVLIN DR	90069	4	147B169   901	5560001019	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Expired	09/08/2016 12:00:00 AM	ADDRESS	34.09576	-118.38732	Install roof mounted solar system on existing residential building.  Total system size = 3.6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47712	12041-10000-24686	3155 N STONE OAK DR	90049	11	159B137   500	4490010008	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.1293	-118.49713	9.8 kw roof mounted PV for a singlefamily. (Enphase M215). MONITORING SYSTEM HAS BEEN ADDED TO PERMIT FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47713	13041-10004-01320	2500 S WESTERN AVE	90018	8	123B193   477	5058015005	C2-1, RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Info Complete	05/14/2015 12:00:00 AM	ADDRESS	34.03373	-118.30879	Change to an approved set by adding (3) circuits on the floor plan. Note. All changes are under delta-23 only((((((4/7/2015)))  PLAN CHECK FOR POWER CHANGES TO FEEDERS AND DISTRIBUTION BOARD DBH-7F AND DBH-6F.Plan check for power   Change of feeders from copper to aluminum, miscellaneous new loads, and (2) additional lighting fixtures (minor T24 changes).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47714	13041-20000-16279	9160 N DEERING AVE	91311	12	198B105   148	2746010032	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM			PC Approved	06/21/2013 12:00:00 AM	ADDRESS	34.23739	-118.59594	RENOVATION OF OFFICE SPACE. OFFICE AND WAREHOUSE SPACE. PC FOR T24 ENERGY ONLY. TOTAL AREA 19121 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47715	18041-20000-24417	1482 N ANGELUS AVE	90026	13	142-5A205 172	5424007022	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.08555	-118.26834	battery back up system only to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47716	15041-20000-35678	21850 W OXNARD ST	91367	3	177B105    80	2146006045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.17895	-118.60413	Plan check for energy only for Guestroom & public space renovation. Conversion of concierge lounge back to guest rooms and meeting room to new lounge. Total area: 46,930 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47717	17041-10000-43082	16521 S ESTRELLA AVE	90247	15	069B201   368	6121005004	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	33.88104	-118.28567	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.03KWdc / 6.72KWac.(21)AC MODULES-SUNPOWER SPR-X21-335-BLK-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47718	19041-20000-13409	14001 W WEDDINGTON ST	91401	4	171B153   296	2247019002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.1668	-118.43795	PV1.  Install 15.840 kW DC / 14.125 kW AC-CEC roof mounted grid tied PV system. (44) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47719	14041-10000-14238	5732 N MURIETTA AVE	91401	2	174B153   408	2246018001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.17487	-118.43873	PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47720	11041-20000-03582	9105 W HAZEN DR	90210	5	153B165    74	4388020014	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.11815	-118.39566	Plan check for a new single family dwelling with 1200A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47721	12041-20000-15562	19755 W VANOWEN ST A-20	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	Full plan check for modification to space A-20.  CHANGE OF USE FROM RETAIL TO HAIR SALON AND INTERIOR TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47722	15041-10000-18431	1999 S AVENUE OF THE STARS SUITE 3200	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI TO AN EXISTING OFFICE SPACE IN HIGH RISE BLD., PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK ON THE 32ND FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47723	15041-10000-30511	700 S FLOWER ST ste 2580	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC for energy only, t-24. Tenant improvement to an high rise building on the 25th floor (offices). Scope of work: new lighting. sq ft = 1977	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47724	19041-20000-52864	14645 W VANOWEN ST	91405	6	183B149   750	2219022018	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	06/16/2020 12:00:00 AM		Permit Finaled	08/11/2021 12:00:00 AM	ADDRESS	34.19406	-118.45247	FULL PC FOR A NEW 600A SERVICE (20/240 1P,3W) THATS FEEDS A 600AMP DISTRIBUTION BOARD THAT SUBFEEDS NINE 100AMP SUBPANELS. THE NEW SERVICE ALSO FEEDS A 100A METER BOARD SECTION FOR ALL ASSOCIATED HOUSE LOADS. TOTAL AFFECTED AREA IS 5371SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47725	11041-20001-01080	13912 W SATICOY ST	91402	6	186B153    32	2214023020	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Expired	05/08/2013 12:00:00 AM	ADDRESS	34.2102	-118.43599	Changes from previously approved plans.  Changes include adding a 30KVA transformer for 480 volt P.V. system and 125A circuit breaker for 120 Volt P.V. system.*****PLAN CHECK FOR ROOF MOUNTED 15.8KW AND 29.9KW PHOTOVOLTAIC SYSTEM FOR 2 EXISTING SERVICES SUPPLYING ONE BUILDING.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47726	18041-10000-44910	1150 S OLIVE ST 15TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.03962	-118.26181	PC for ENERGY ONLY, TI PORTION OF 15TH FLOOR:SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUITS. TOTAL SQ. FT. 7802	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47727	14041-10000-32840	255 S MARIPOSA AVE	90004	10	135B197   110	5518007009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM			Reviewed by Supervisor	01/07/2015 12:00:00 AM	ADDRESS	34.06965	-118.29936	Full plan check per customer request; Energy plan check based on 2008 standard due to building permit 10016-10000-08786.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47728	17041-10000-04191	4122 N GLENALBYN DR 1-58	90065	1	145-5A223  16	5465022900	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	Apartment			02/08/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Issued	02/08/2017 12:00:00 AM	ADDRESS	34.09509	-118.21209	Plan check for Fire alarm system in existing appartment building 1 FACP  6 smoke detectors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47729	19041-20000-49857	15063 W GILMORE ST	91411	6	180B145   667	2235019029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.18776	-118.46174	PV1.  Install 11.220 kW roof mounted PV system.  (34) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47730	16041-10000-26953	3071 W OLYMPIC BLVD	90006	10	129B193   267	5080031054	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.05278	-118.30252	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (OUTDOOR) 7585 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47731	19041-20001-49396	5831 N COLUMBUS AVE	91411	4	174B145    81	2243018008	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.17675	-118.4641	EXPEDITED FEESNEW ROOF MOUNTED SOLAR SYSTEM USING SOLAR TILES AND CENTRAL INVERTER AND AC COUPLED BATTERY SYSTEM( TOTAL 27KWH / 10 KW ). TOTAL PV SYSTEM SIZE IS 6.55 KWDC/ 7.6 KWAC..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47732	15041-20001-01339	6858 N LONGRIDGE AVE	91605	2	183B157   749	2327007064	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2015 12:00:00 AM			PC Approved	02/25/2015 12:00:00 AM	ADDRESS	34.19558	-118.4213	[[[[ Change to approved set of plan switch modules from AXITEC AC-300P/156-72S to CANADIAN SOLAR CS6X-310M]]]]PV1 SFD. TOTAL SYSTEM SIZE 3.6KW DC/ 6KW MAX AC. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 12 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47733	15041-10000-32317	1030 W MARTIN LUTHER KING, JR BLVD STE 102-103	90037	9	114B197   259	5020029027	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.01067	-118.29278	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE/FINANCIAL TRANSACTIONS AREA). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 1488 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47734	11041-20000-13213	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	33.89279	-118.28725	RENOVATION ROSS DEPT STOREREQUEST FOR MODIFICATION TO SEPARATE FIRE ALARM SYSTEM FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47735	18041-20001-00946	4074 S BROADWAY	90037	9	115-5A203 294	5111022027	M1-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.00948	-118.27813	03/13/2018 Plan check for Title 24 only. Project site is a parking lot. Total outdoor lighting area = 6,304 sq. ft.Note: Building permit has been issued under 18020-20000-00333*****Previous Work Description*****INSTALL MAIN SERVICE 100 AMP.  INSTALL 3 POST LIGHT WITH 2 LIGHT LED EACH.  INSTALL 120V 20 AMP LINE FOR GATE.  INSTALL 3 GFI PLUGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47736	16041-20000-17381	171 S NORMANDIE AVE	90004	10	138B193  1263	5518002040	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.07169	-118.30055	"""0$ permit fees due to senate bill 1222""PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 40KW INTERCONNECTED WITH MSP."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47737	19041-20000-41382	11841 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47738	18041-10000-03463	11601 W WILSHIRE BLVD #370.	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	TENANT IMPROVMENT TO THE (E) OFFICE SPACE IN A HIGHRISE BUILD. , INSTALL NEW LIGHTS AND RECEPTACLES USING EXISTING CIRCUITS.((B# 17016-20000-35200)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47739	18041-20001-31226	8943 N OSO AVE	91311	12	195B113    39	2781001016	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.23374	-118.57549	04/24/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to reflect field conditions.*****Previous Work Description*****FULL PLAN CHECK (POWER+ENERGY) TO REPAIR OF FIRE DAMAGED INDUSTRIAL BLDG TO A CORE AND SHELL CONDITION. COMPLETELY OVER 500A OF NEW LOADS  ARE CONNECTED TO (E) 600A SWITCHBOARD, NEW PANELBOARDS AND HVAC LOADS. TOTAL AREA: 4,429 SQ.FT(B# 18016-70000-24067)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47740	14041-20000-31636	700 S FLOWER ST 6th floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	TENANT IMPROVEMENT TO EXISTING OFFICE BUILDING (6TH FLOOR) new lighitng. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47741	10041-10000-03132	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	NEW SERVICES AND FEEDERS TO SUPPLY POWER TO  EXISTING AND NEW STRUCTURES  AT HOTEL BEL-AIR.  AND SITE LIGHTING.  HATCHED AREA ON THE SINGLE LINE ARE ON SEPARATE APPLICATIONS AND PERMITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47742	12041-10000-28401	1722 S CHASTAIN PKWY EAST	90272	11	138B121   119	4431041074	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.07466	-118.54755	mICRO INVERTER, 43 MODULES AND 43 MICRO INVERTERS, TOTAL 10.7 KW, 2 COMBINER BOXES AND 2 CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47743	19041-10001-49758	10475 W WILSHIRE BLVD	90024	5	135B157   250	4360029251	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.06535	-118.43154	"TI in an existing commercial bulding. Installing lights in the commom areas such as meeting rooms, lobbies & restrooms of the ""Ground"" floor, ""First"" floor & ""6th"" floor. T-24 energy only. ALL EMERGENCY LIGHTS AND EXIT SIGNS ARE EXISTING TO REMAIN - SUBJECT TO FIELD INSPECTION.Plan check only. Permit # 19041-90000-49758."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47744	14041-10000-23268	5273 E RABER ST	90042	14	157-5A227  72	5479006012	RE11-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.12727	-118.19876	PV1 6.12KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(2) inverters: {PVI-3.0-OUTD-US }]. [(24)modules: {kyocera KD255GX-LFB3}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47745	14041-20000-19496	11290 N WOODCOCK AVE	91331	7	210B157    78	2534005005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.27531	-118.42021	New roof mounted PV system with Enphase, model M215--60-2LL.  Total system size 4.0 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47746	14041-20000-01998	3859 S DENKER AVE	90062	8	117B193  1181	5036012022	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			Corrections Issued	01/23/2014 12:00:00 AM	ADDRESS	34.01566	-118.30472	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47747	15041-20000-22781	6320 N TOPANGA CANYON BLVD G-1630	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title-24 (energy).  Total area = 1,825 sq. ft.  T.I. to existing retail rfirst time tenant.  New electrical distribution equipment, plug loads, HVAC, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47748	13041-10000-01346	9779 W OAK PASS ROAD	90210	5	156B157   467	4385013004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2013 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Closed	07/22/2017 12:00:00 AM	ADDRESS	34.11983	-118.42761	FIRE ALARM SYSTEM. ELEVATOR RECALL SYSTEM. FIRE ALARM PANEL AND 7 MODULES.SINGLE FAMILY DWELLING. 3 STORY DWELLING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47749	18041-20002-02539	6927 N REMMET AVE unit b	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	08/02/2018 Changes to an approved set of plans. Plans updated to match revised service configuration.*****Previous Work Description*****pv2install roof mounted pv system sized 5kw interconnected with msp to unit B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47750	16041-10000-36476	440 N VIRGIL AVE	90004	13	141A201   352	5539035028	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM			Reviewed by Supervisor	10/27/2016 12:00:00 AM	ADDRESS	34.07898	-118.28659	PV, INSTALLATION OF 5.520 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MICROINVERTERS: SUNPOWER SPR-X1-345-C-ACSystem include a battery rated at 8kw -  Sonnen  eco 16	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47751	14041-20000-15746	4719 N SAN SEBASTIAN DR	91364	3	168B097   689	2076011023	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.15395	-118.61963	PV1: 5KW roof-mounted system with (20) Trina Solar TSM-255 modules, (20) Solaredge P300-2NA4AZS Power Optimizer, and a 5KW Solaredge SE5000A-US-ZB inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47752	16041-20000-15914	700 S FLOWER ST Ste 630	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to (E) commercial office space in commercial highrise building.  Plan check for energy.   1347 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47753	15041-20000-28078	6416 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.1874	-118.6425	Plan check Title 24 only for barber shop T.I. Total indoor area: 1,067 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47754	17041-10002-42224	2305 S PADUA PL	90291	11	108B149   840	4237009006	R3-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	33.99194	-118.45582	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM AND SITE PLAN TO REFLECT AS BUILT. RELOCATING PV POINT OF INTERCONNECTION AND SHOWING EXISTING AC DISCONNECT.NOTE: PLAN CHECK ONLY. PERMIT HAS BEEN PULLED UNDER MASTER APPLICATION 17041-10000-42224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47755	16041-10000-43628	5355 N VAN NUYS BLVD	91401	4	172-5A151  26	2249004017	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.16824	-118.44892	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXTERIOR HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 52975 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47756	13041-10000-35479	4617 E HUNTINGTON DR NORTH	90032	14	142-5A231  34	5213012045	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.0864	-118.18681	PLANCHECK FOR POWER AND ENERGY.  FOR DOLLAR TREE. 10000 SQFT. existing service and distribution board, not new service or a core/shell (actually TI from retail to retail) . changes on plans: panels changed to fully rated 22kaic.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47757	18041-10000-08864	15903 W VENTURA BLVD	91436	5	168B141   589	2261021103	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM			PC Info Complete	03/12/2018 12:00:00 AM	ADDRESS	34.15607	-118.47954	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING LIGHTS IN A COMMERCIAL BANK. TOTAL AFFECTED AREA IS 10219 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47758	11041-10000-24859	8500 W BEVERLY BLVD # 743	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Expired	11/20/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	CONVERT ADJACENT VACANT TENANT SPACE TO STOCK ROOM FOR ADJACENT GUCCI STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47759	16041-10000-06526	725 S FIGUEROA ST SUITE 4050	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	"TENANT IMPROVEMENT TO EXISTING OFFICE SUITE ""TRIFECTA MULTI-MEDIA"", PC FOR ENERGY ONLY. TOTAL AREA 4,685 SQ.FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47760	15041-10000-36595	3785 W WILSHIRE BLVD unit 217	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.06187	-118.30858	Full PC. Change of use from retail to restaurant on a commercial building. Scope of work is being done on the 2nd floor (unit 217). Occupancy A2.  Sq ft = 2767.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47761	18041-10000-45109	16840 W KNOLLWOOD DR	91344	12	213B137    24	2610016019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Issued	11/27/2018 12:00:00 AM	ADDRESS	34.28445	-118.49836	Plan check for a 6.4KW AC PV1 roofmounted system with (21) modules and enphase microinverters interconnecting through a subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47762	19041-20000-15605	2933 1/2 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.10434	-118.24366	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47763	17041-20001-21886	14828 W RAYEN ST #1-14	91402	6	195B149   279	2653005002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	34.23171	-118.45633	9/4/2018changes to an approved set of plans.  changes to service feed from underground to overhead.  plan check for power only.  this is plan check only.(((New 3-story, 14-unit apartment building.  800 A 120/240V 1ph-3w service.  Building permit filed under 16010-20000-03664)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47764	18041-20000-37570	23912 W SCHOENBORN ST	91304	12	192B089   139	2017037007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM			Corrections Issued	10/02/2018 12:00:00 AM	ADDRESS	34.22082	-118.64745	Installation of 27 kWh energy storage system and critical load panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47765	13041-20000-00284	5900 W WILSHIRE BLVD 11th Floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/04/2013 12:00:00 AM			PC Approved	01/04/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for bathroom. 11th floor. 481 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47766	16041-10000-17645	755 E 82ND ST	90001	9	099B205  1165	6029010014	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.96479	-118.2611	INSTALLATION OF NEW ROOF MOUNTED SOLAR PV ARRAY ON EXISTING SINGLE FAMILY DWELLING.  TOTAL SYSTEM SIZE = 5 KWAC.  CENTRAL INVERTER SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47767	09041-10002-07807	8612 W BURTON WAY Units 1-11	90048	5	138B169   715	4334016008	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Apartment			10/13/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	10/18/2011 12:00:00 AM	ADDRESS	34.07189	-118.37986	in a level 2 methane site, install a methane sensor  in the garage area below grade; Sensor and conrolerpanel are compatible.(((((((((NEW FOUR STORY,  11-UNIT APARTMENT BUILDING OVER A TWO LEVEL BASEMENT PARKING GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47768	15041-20000-34972	8950 N GLENOAKS BLVD	91352	6	195B173   149	2408005031	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.2319	-118.36828	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING'S ROOF-TOP. TOTAL SYSTEM SIZE IS 68.85 KWac. (300) MODULES- QCELL.PRO BFR-G3 255-265(300) OPTIMIZERS-SOLAREDGE P300(6)INVERTERS-SOLAREDGE SE11400A-US(1) 225A LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47769	17041-10000-04927	1118 N MCCADDEN PL	90038	4	144B185   681	5532021029	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.09129	-118.33733	********PC SHALL VERIFY FEES ON THE PLANS. TITLE 24 SHEETS incomplete.total area according to electrical designer should be around 71000 sq.ft. Verify fees for Energy.  Update description !!!FULL PC FOR POWER AND ENERGY FOR A 4-STORY RETAIL, OFFICE, CLASSROOMS, AND SENIOR CENTER BUILDING. SCOPE INCLUDES A NEW 4000A 277/480V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. B#16010-10000-01468	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47770	15041-10000-36492	815 W 41ST ST	90037	9	114B197   413	5019002015	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.00929	-118.28782	PV1, roof mounted solar system 5.035kW(19) modules: #KU2656ZPA(1) inverter #PVI-3.6-OUTD-S-US-Z-AStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47771	13041-20001-33864	10618 N MELVIN AVE	91326	12	207B117   322	2708005005	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.26301	-118.55991	((EXPEDITE FEES))PV1 TRANFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC. 36 MODULES AND 2 INVERTERS. SUBMITTED PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47772	14041-20002-06440	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	"Changes from a previous approved plans (14041-20001-06440).  Change include feeder size to ""Buffalo Wild Wing"".  Delta 13, all  terminals rated at 90 degree. Change in terminations to meet 90 degree rated shall not violate listing of any equipment connected to."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47773	15041-10000-43653	519 W 120TH ST	90044	15	084B201  1089	6088027033	RD2-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	33.92386	-118.2834	PV1 roof mounted solar system installation to a single family home. Inverter: 4.2 kw, (18) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47774	11041-10000-13501	1916 W COLORADO BLVD Ste E & F	90041	14	162A223   106	5686007006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Finaled	01/17/2012 12:00:00 AM	ADDRESS	34.13906	-118.20911	New dental office.  Space used to be an auto repair shop.  New tenant will be reusing all existing panels.  Only new items will be the branch circuits.  Medical office with no chronic dialysis or surgical services,not plan reviewed for Oshpd III Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47775	17041-10000-28494	8500 S FIGUEROA ST	90003	8	097-5A201 184	6032035043	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	33.96105	-118.28251	PC for fire alarm system with 121 devices and 1 FACP panel and 1 annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47776	10041-10000-12568	6400 N TAMPA AVE	91335	3	180B117   788	2128031153	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.18677	-118.55325	TI in an existing commercial space. Yogurtland. Plan Check is for T-24 Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47777	11041-20000-20034	11868 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	34.28596	-118.50158	PLAN CHECK T24 ENERGY FOR NAIL SALON TENANT IMPROVEMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47778	12041-10000-28893	301 S CENTRAL AVE 1ST FL	90013	9	129A215   283	5147003038	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.04602	-118.23981	TI AND CHANGE IN USE FROM RETAIL TO OFFICES ON THE 1ST FLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47779	15041-10001-39021	8631 W 3RD ST #940E	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	12/10/2015Changes to approved set of plans. Changes include removing emergency fixtures from procedure rooms and reverting to bi level controls due to modification in place, table 141.0-F. (((T-24, TI TO A MEDICAL OFFICE SPACE IN A HIGHRISE BUILDING, STE #940E. SCOPE OF WORK INCLUDES ONLY NEW LIGHITNG. TOTAL SQ. FT. 1135.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47780	14041-20001-07399	11550 N INDIAN HILLS ROAD	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.27998	-118.45874	(((Expedite fees)))PV2 110.4KWAC SYSTEM FOR COMMERCIAL SPACE. BUILDING APPROVAL IS REQUIRED BEFORE PERMIT CAN BE ISSUED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47781	15041-20000-18910	5446 N NEWCASTLE AVE	91316	5	174B129   974	2162009191	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.16989	-118.5242	Installation of new roof mounted solar PV array.  Total system size = 33 kWac.  Three inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47782	14041-10000-19481	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.11883	-118.2495	Fire alarm system for new building and existing building.  Total number of devices = 466	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47783	18041-20000-34935	415 S LE DOUX ROAD	90048	5	138B173  1050	4334016038	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.07126	-118.37768	Plan check for new Fire alarm system for new multi-family 5 story 19 units. Total fire alarm devices: 104 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47784	18041-10000-35047	100 N JUNE ST	90004	4	138B185   233	5515003008	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM			Reviewed by Supervisor	09/27/2018 12:00:00 AM	ADDRESS	34.07414	-118.33414	Plan check for Power only on a Single Family Dwelling, Install New equipments: (1) 20kW Back up Generator,  (3) 4.8 kWh Battery Bank, (4) 5kW inverters, (1) 100A  AC combiner panel. There's existing PV system on site.<<PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.712 KWac. (24) AC MODULES-SUNPOWER SPR-250-BLK-AC (1) 100A LOAD CENTER+>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47785	16041-10000-37815	625 S BARRINGTON AVE unit 1-46	90049	11	132B145   276	4401012012	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.05687	-118.46824	PC FOR 46UNIT APT BUILDING.POWER AND ENERGY SCOPE INCLUDES  1600A SERVICE (208/120)  TOTAL AREA OF 41700SQ.FT (INDOOR & OUTDOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47786	18041-20000-01165	6025 N CRANER AVE 1-6	91606	2	177B173  1025	2414004013	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Apartment			01/11/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.18011	-118.36945	Plan check for power and energy. Project site is a new 4-story, 6-unit apartment building. Work includes a 600-amp service and a total lighting area of 9,296 sq. ft.Note: Building application has been generated under 17010-10000-02256.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47787	15041-30000-37291	10300 W WILSHIRE BLVD	90024	5	135B157   117	4327013027	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.06768	-118.42561	Installation of new roof mounted solar PV array on existing hotel.  Total system size = 120 kWac.  System consists of 5 identical 24 kWac inverters with 97 modules each.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47788	14041-10000-05098	3650 E OLYMPIC BLVD 2ND FLOOR	90023	14	118-5A227 227	5191024011	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.01861	-118.1992	PLAN CHECK FOR A NEW FIRE ALARM SYSTEM WITH 23 DEVICES PER INSPECTORS REQUEST. PERMIT PREVIOUSLY PULLED  FOR 23 DEVICES UNDER 14041-10000-03787. FACP PLANCHECKED FOR THE 23 DEVICES, FACP WAS PERMITED PREVIOUSLY UNDER 13041-10000-24244. ALL DEVICES TO BE INSTALLED ARE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47789	12041-20000-05007	2029 S CENTURY PARK EAST 710/715-North	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24 lighting plan check for a remodeled tenant space suite 710/715 North.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47790	15041-20000-27335	6255 W SUNSET BLVD 21st Floor	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			Not Ready to Issue	08/20/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for Title 24 only in existing highrise. Total indoor area: 14,503 sqft.Permit was issued under: 19041-30000-07474	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47791	14041-10000-26442	11220 S HINDRY AVE	90045	11	087B173   101	4129038019	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.93221	-118.37223	Title 24 plan check only.Remove HID light fixtures and replace with LED fixtures.Total area = 25,944 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47792	13041-10000-33776	2121 S AVENUE OF THE STARS 30th	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check for title 24 only.TI of existing office to office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47793	16041-20000-04536	19400 W VALERIO ST	91335	3	186B117   634	2116017035	RD5-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.20462	-118.55615	Fee is $0.00 due to 2012 CA State Senate Bill 1222.Plan check for a PV2 roof-mounted PV system (on a church). System size is 36kWac and consists of (4) 9kW inverters, (150) modules, (75) P600 optimizers, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47794	16041-20000-23657	10130 N TOPANGA CANYON BLVD	91311	12	204B101   367	2747017039	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.25473	-118.60582	Plan check Title 24 only in existing retail space T.I. Total area: 1,510 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47795	14041-20000-06070	8319 N LANKERSHIM BLVD	91605	6	192B169   465	2310006001	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.22169	-118.38815	pc for new lighting. t24 energy only. retail use	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47796	17041-10000-18023	1466 W JOHN S GIBSON BLVD BERTH136-BERTH139	90810	15	027B201   431	7440008901	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	33.76837	-118.28032	RELOCATING (2) 6.6KV - AMP - OUTLETS TO BE RELOCATED NEW WIRING - CONDUITS AND EQUIPMENT ALREADY IN PLACE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47797	19041-20001-09615	4347 N CORONET DR	91316	5	165B129   145	2184030004	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM			PC Approved	04/30/2019 12:00:00 AM	ADDRESS	34.15063	-118.51909	Revision to approved plans.  Change of module locations on rooftop.  $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((INSTALLING A 10.89KW DC/7.6KW AC ROOFTOP PV SYSTEM. SCOPE OF WORK INCLUDES (1) SE7600 INVERTER, AND (33) PANASONIC 330W PV MODULES WITH P400 OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47798	11041-10001-07038	7800 N HASKELL AVE	91406	6	189B141   209	2206001020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.21241	-118.47476	TI IN AN EXISTING WARHOUSE BUILDING.  INSTALL NEW PANELS, 112.5KVA TRANSFORMER AND CIRCUITS.  PLAN CHECK IS FOR POWER & ENERGY.   <<<<<Office area checked under 11041-10000-07038>>>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47799	13041-10000-28619	8750 S SEPULVEDA BLVD	90045	11	096B165   910	4123002001	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	33.95743	-118.39597	TITLE 24 ENERGY PLAN CHECK ONLY. SERVICE SIZE BELOW 400 AMPS. 1144 SQFT, EMERGENCY LIGHTING. CHANGE OF USE FROM BANK TO RESTAURANT. YOGURTLAND. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47800	10041-20000-04897	2530 E CINCINNATI ST	90033	14	129A225   348	5177033028	R3-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2037.20	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	10/28/2011 12:00:00 AM	ADDRESS	34.04626	-118.20433	New building variety boy and girls community center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47801	18041-10000-31233	6831 N VINELAND AVE	91605	2	183B173   213	2319005022	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.19523	-118.37056	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47802	17041-10000-09030	505 N SILVER LAKE BLVD	90026	13	139-5A203 706	5401013010	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	05/06/2022 12:00:00 AM	ADDRESS	34.078	-118.28001	POWER AND ENERGY PLAN CHECK FOR A 4-STORY AND 48 UNIT-APARTMENTBUILDING. PROJECT IS LOCATED IN A  METHANE BUFFER ZONE. TOTAL ENERGY PLAN CHECK AREA IS 32,000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47803	18041-10000-29384	348 S HAUSER BLVD	90036	4	135B181   117	5509005002	(Q)R4-2-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Apartment			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.06889	-118.35048	PC PER APPLICANT REQUEST TO RELOCATE GATE MOTORS TO EM. PANELS. TOTAL 14 RELOCATED CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47804	16041-10001-21669	888 S OLIVE ST	90014	14	127-5A209 127	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM			PC Approved	10/25/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	SUPPLEMENTAL TO APPROVED SET OF PLAN (10/25/16). CHANGING EMERGENCY CIRCUITS CONNECTION PER INSPECTOR REQUEST. CHANGES UNDER DELTA 2. T24 PLAN CHECK ONLY. ----------------------------------------------------------------------------------------------------------------------------------------------------<<<<PC FOR FULL PLAN CHECK. 1ST TIME TI TO (N) RESTAURANT. TOTAL AREA 2230 SQ FT.B# 16061-10000-14317>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47805	14041-20000-12306	15760 W VENTURA BLVD A-26	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.1552	-118.47684	Tittle 24 plan check for (6) office only on suite A-026	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47806	08041-20001-01846	2025 S FIGUEROA ST	90007	9	123A205    30	5126003025	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM			PC Approved	10/06/2010 12:00:00 AM	ADDRESS	34.03246	-118.27359	Plan check only. Changes from previously approved plans.  Changes in lighting and T-24 calculation with area exceed 30,000 s.f.  All changes indicate by DELTA 4 as shown on plans. *****Delta 2 revisions to PCIS # 06041-20000-23254.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47807	10041-10000-17141	8403 N FALLBROOK AVE	91304	12	192B097   589	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.22129	-118.62628	Install new 800A switchboard and ATS.  Plan check for power. Disconnect existing load from main switchboard reconnect to new switchboard and emergency generator. Misc permit for existing panels and ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47808	17041-10000-04817	5307 N SEPULVEDA BLVD	91411	4	172-5A145  58	2250001002	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			02/14/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Issued	09/25/2017 12:00:00 AM	ADDRESS	34.16692	-118.46643	Note: Permit is $0 due to Senate Bill 1222. PV2, Plan check for PV roof mounted system. System size: 144kW with 4 inverters(36kW) Yaskawa PVI 36TL and 468 Modules SUNPOWER X21-345-COM connected to 1000A switch borad	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47809	18041-20000-05742	1228 E 8TH ST	90021	14	124-5A213 447	5146018004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.03411	-118.24417	Plan check for a fire alarm system for a commercial building. Fire alarm system consists of (1) FACP, (1) annunciator, and (21) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47810	19041-20000-41749	8629 W WENTWORTH ST	91040	7	207B189   122	2551043056	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.26716	-118.32108	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 6 KW DC/5.29 KW AC CEC. SCOPE OF WORK CONSISTS OF (20) PV MODULES WITH MICRO INVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47811	12041-10000-30303	111 E UNIVERSAL HOLLYWOOD DR LL & TER	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	CHANGE OF USE FROM OFFICE TO EXERCISE ROOM.  PRIVATE FITNESS CENTER FOR USE BY BUILDING TENANTS ONLY. TERRACE= 2165 SQ  LOWER LEVEL= 1990 SQPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47812	12041-20000-19153	10201 W PICO BLVD Bldg 105	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check for new 4 story commercial building. Power, energy, and emergency lighting. Fee counts per customer (additional fees may be required). Fox Studio Building 105	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47813	19041-20000-32055	20807 W ACORN CIR UNIT #166	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	34.29452	-118.58684	PV1.  Install 3.15 kW roof mounted PV system.  (9) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47814	15041-10000-25612	200 WORLD WAY TERM 2-LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM			PC Approved	08/07/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	ALTERATIONS TO EXISTING STORAGE AREAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47815	18041-10000-03934	8441 N RESEDA BLVD	91324	12	192B125   381	2785018059	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Issued	02/02/2018 12:00:00 AM	ADDRESS	34.22391	-118.53629	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47816	15041-10000-21150	11557 N DRONFIELD AVE	91331	7	213B161   611	2532005012	A2-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.27964	-118.40661	PV1 6kW roof-mounted system with (22) Sunpower SPR327NE modules,  and (1) ABB PVI-6000_OUTD inverter interconnecting through a main service panel.Note. Applicant is notified about the online service, but insists to submit the plan as regular plan check.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47817	17041-20000-44134	700 S FLOWER ST Ste 860	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Tenant improvement okf (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47818	12041-10000-20548	7928 W HOLLYWOOD BLVD 1-79	90046	5	147B177   425	5551016003	R3-1XL	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.10106	-118.36259	NEW FIRE ALARM SYSTEM IN A NEW 4 STORY APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47819	17041-10000-05637	8744-8754 1/2 S BELFORD AVE B.DG 3	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Closed	05/29/2020 12:00:00 AM	ADDRESS	33.95708	-118.3838	PC FOR POWER ONLY FOR A NEW 600A 120/208 1 PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD, AND NEW SUBPANELS. SERVICE IS FOR AN EXISTING 12 UNIT TENANT SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47820	18041-30000-41472	601 S FIGUEROA ST 24th floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for T24 only, Tenant improvement to (e) Restroom area: 535 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47821	13041-20001-15552	4539 N MARMION WAY PV 1	90065	14	147A223   131	5466023008	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Expired	07/20/2015 12:00:00 AM	ADDRESS	34.09754	-118.20824	(((6/25/2013: CHANGED TO TRANSFORMERLESS INVERTER. 8 MODULES AND 1 INVERTER.)))INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM. 1.47 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47822	14041-20000-03438	6733 N YOLANDA AVE	91335	3	180B121   796	2126037052	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.19291	-118.54059	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47823	16041-10000-11250	2960 W BROADWAY	90041	14	165A217    42	5680027020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.14564	-118.22857	Power and Enegry plan check. Service and panel upgrades with all new branch circuits for GAS STATION with convience store and car wash. Service upgrade from 400A to 1200A. 5 New panels. 23513 sqrft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47824	14041-20000-23528	14612 W VENTURA BLVD	91403	4	166-5A151 119	2276001016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.15118	-118.45135	TI FOR A RESTAURANT.  NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTING.PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47825	16041-20000-17860	15760 W VENTURA BLVD SUITE 900	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Issued	05/20/2016 12:00:00 AM	ADDRESS	34.1552	-118.47684	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AD EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 4967.  SCOPE OF WORK IN SUITE 900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47826	10041-20000-20431	8616-8618 W PICO BLVD	90035	5	129B173    54	4303019004	C4-1-O	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	04/28/2011 12:00:00 AM	ADDRESS	34.05368	-118.37902	"PLAN CHECK POWER AND ENERGY FOR T.I. CHANGE OF USE FROM ""RETAIL"" TO ""WINE MARKET & TASTING"" ROOM (A3 OCCUPANCY TYPE)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47827	18041-10001-04538	2560 W OLYMPIC BLVD # 101B	90006	1	130-5A201 141	5076008030	(Q)C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.05219	-118.28707	[[[4/418 CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. DELTA 2 CHANGES ONLY.  CHANGING THE SERIES RATING TO REFLECT INSTALLATION]]]FULL PC FOR POWER AND ENERGY,  MEDICAL OFFICE SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1770.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47828	17041-10000-39625	4501 W COLORADO BLVD B7	90039	13	162B205    19	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Issued	12/15/2017 12:00:00 AM	ADDRESS	34.14246	-118.2705	PC for power for install of new computer server room system. Installing two new distribution boards connected to upstream ATS, computer servers, equipment, three panels and system is backed up by UPS unit. This permit covers installation for the Shire building 1. B# 17016-10000-16114.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47829	11041-20000-26684	12000 W RIVERSIDE DR 1-96	91607	2	168B165  1092	2355014128	(Q)R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.15739	-118.39452	New fire alarm system for three story apartment building.  83 devices and 1 fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47830	19041-10000-30944	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1-RIO, RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	34.15777	-118.43065	Full plan check for power and energy, scope of work is a new 3 story parking structure Type IB. Scope of work includes four new panels, a new emergency inverter, and a new 300 kva transformer. Service is existing 3000A 277/480 three phase four wire. Total affected area is 78011 sqft.B# 19010-20000-02332	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47831	14041-20000-01948	7047 N FIRMAMENT AVE	91406	6	183B141   300	2222036009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.19884	-118.47263	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47832	19041-10000-49095	4060 S GLENCOE AVE 1-96	90292	11	108B153  1415	4230007***	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			11/27/2019 12:00:00 AM			Ready to Issue	01/04/2022 12:00:00 AM	ADDRESS	33.99053	-118.44315	INSTALLATION OF 40 NEW EV CHARGERS AT 7.2 KW AND 2 SUB PANELS. SERVICE SIZE IS 120/208 V, 200 A, 3� 4 WIRE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47833	10041-10000-15757	2709 E MEDIA CENTER DR	90039	14	150B213  3653	5442032001	[Q]M1-1-CDO, [Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.00	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	PIN	34.11096076	-118.24539883	10 kw interactive photovoltaic system on roof of charter scheool	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47834	13041-20000-34261	6844 N WOODMAN AVE	91405	2	183B157   830	2328012040	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			12/10/2013 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.19531	-118.43098	NEW 15 UNIT APARTMENT.  NEW 1000A SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47835	12041-10000-01673	3650 S MCCLINTOCK AVE Floors 1-5	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Approved	01/24/2012 12:00:00 AM	ADDRESS	34.02081	-118.28964	Plan check T24 Energy for restrooms, canopy upgrade on floors 1 thru 5. Mandatory measures in office spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47836	16041-20000-09399	7633 N MASON AVE	91306	3	186B109   133	2108024032	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.20945	-118.57992	Plan check for a PV1 roof-mounted PV system. System size is 8 kWac and consists of (2) inverters, (37) modules, (1) load center, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47837	18041-10000-44595	6801 W HOLLYWOOD BLVD #271	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.10229	-118.33907	"NEW ""FOREVER 21"" RETAIL STORE IN UNIT# 271. PLAN CHECK FOR POWER & ENERGY. 11,020 SQR FEET. BUILDNG PERMIT: 18016-10000-37709"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47838	11041-20000-18764	127 S SAN VICENTE BLVD Bulletin-100	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 100  plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47839	16041-30000-17317	4209 W SANTA ROSALIA DR	90008	10	117B181   746	5032009012	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01304	-118.34503	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01104	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47840	09041-20002-22257	1016 N SYCAMORE AVE	90038	4	144B181   575	5532030010	MR1-1	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM	03/10/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.0895	-118.34265	SUPPLIMENTAL PERMIT TO EXISTING PERMIT NUMBER 10041-20000-22257 ADDING ADDITIONAL 10 CIRCUIT, 1 PANEL AND 200 FEET CABLE TREY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47841	16041-10000-27460	7945 N TOPANGA CANYON BLVD	91304	3	189B101   290	2012012016	(T)(Q)R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.21507	-118.60621	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING SENIOR ASSISTED LIVING BLDG. SCOPE INCLUDES 213 FA DEVICES, 1 FA PANEL, 1 COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47842	17041-10000-08114	18923 W VENTURA BLVD	91356	3	174B121   409	2161001042	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.17261	-118.54573	T24 ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES 8600 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47843	16041-10000-41416	3650 N BARHAM BLVD BLDG T	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.13881	-118.34145	PC FOR NEW PANELS, STACKED WASHERS & DRYERS IN CERTAIN APT. UNITS  IN BUILDING T OF CAMPUS STYLE COMPLEX.. THIS IS BUILDING 5/6(Add 1 laundry ckt to 45 units, and 1 microwave ckt to all 69 units in the building, total 114 new ckt in the building.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47844	13041-10000-09525	19336 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.23457	-118.55496	TITLE 24 PLAN CHECK FOR A NEW GROWLER STATION AT A WINE AND SPIRITS MARKET.  160 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47845	14041-10001-18031	1022 S SIERRA BONITA AVE	90019	4	132B177   844	5085004005	R1-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.05676	-118.3561	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSSTALL 7.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(27) MODULES: LG SOLAR LG265S1C-A3(27) MICRO INVERTER: ENPHASE M215-60-2LL-SX-IG 240V}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47846	17041-10000-14090	827 S BERENDO ST	90005	10	132B197   613	5094014024	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Closed	01/04/2023 12:00:00 AM	ADDRESS	34.05695	-118.29428	Remove Metal Halide fixture and replace with new LED fixrures- T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47847	15041-10000-02728	6325 W RODGERTON DR	90068	4	157-5A189 162	5582010019	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.12578	-118.32282	PV1, 8250 W DC GROUND -MOUNTED SOLAR ARRAY IN A ONE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL. 3 STRINGS. ONE INVERTER: SMA AMERICA SMA-SB7000-US(33)MODULES: PHONO SOLAR PS250P	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47848	18041-10002-20335	6505 S ESPLANADE #2	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	33.96159	-118.45071	Change to approved set by changing the inverter from 3.3KW to 3.8KW. All changes under delta-2 only.(((PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW LOAD CENTER, 6 MODULES(#SC325) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 1.95KWdc.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47849	13041-10000-10814	5815 W SUNSET BLVD 301	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/26/2013 12:00:00 AM			PC Approved	04/26/2013 12:00:00 AM	ADDRESS	34.09822	-118.31613	13041-10000-10814TITLE 24 FOR EXISTING SHOWROOM. 800 SQ.FT. SCOPE OF WORK IN UNIT 301. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47850	19041-10000-02191	333 S HOPE ST 53rd Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	TENANT IMPROVEMENT TO THE 53th FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.BUILDING PERMIT: 18016-10000-38166.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47851	14041-10000-33826	11961 W SHERMAN ROAD	91605	2	183B165    24	2317016004	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.20129	-118.39418	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47852	19041-10001-49580	9853 N AURA AVE	91324	12	201B117   133	2761010050	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM			PC Approved	01/08/2020 12:00:00 AM	ADDRESS	34.24965	-118.55459	PC for PV-1 system, system size 10.560KW, 33 Modules With 320 optimiziers, 1 solaredge SE7600-US.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47853	19041-10000-09862	1405 S WELLESLEY AVE	90025	11	126B145   801	4267032015	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Apartment			03/19/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	12/29/2020 12:00:00 AM	ADDRESS	34.03973	-118.46588	NEW FIRE ALARM SYSTEM IN A 2 STORY APPARTMENT COMPLEX. SYSTEM INCLUDES 1 FACP, 2 POWER SUPPLIES, CELLULAR DAILER PANEL AND 205 FA DEVICES. PLANS ARE SUBMITTED TO LAFD CONSECUTIVELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47854	17041-20001-40728	5511 W THORNBURN ST	90045	11	102B173   437	4103009013	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			06/05/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	33.97271	-118.3762	06-05-2018 Changes to an approved set of plan. Changes include MS2 distribution rating reduce to 800A 3 phase and revise feeder to reflect 3 phase conductor. All Changes has been clouded. as delat C. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47855	13041-10000-05303	4451 N HAYVENHURST AVE	91436	5	165B137    90	2284010025	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Expired	03/31/2015 12:00:00 AM	ADDRESS	34.15159	-118.49304	PV1 ROOF MOUNTED SOLAR INSTALLATION FOR 1 STORY DWELLING ON STANDARD PLAN. SYSTEM SIZE IS 10.56KW [INVERTER: FRONIUS# IG PLUS V 7.5 |||| MODULES: TRINA SOLAR # TSM-240 PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47856	14041-20000-06284	1601 S SOTO ST	90023	14	120A221   205	5169014003	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Expired	04/13/2016 12:00:00 AM	ADDRESS	34.02091	-118.2204	TI FOR EXISTING TWO STORY OFFICE BUILDING. PLAN CHECK FOR ENERGY ONLY. INVESTIGATION FEE TO BE COLLECTED DURING PERMITTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47857	14041-20001-20451	12030 N BEAUFAIT AVE	91326	12	216B125    28	2870004029	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM			PC Approved	08/05/2014 12:00:00 AM	ADDRESS	34.29169	-118.53667	Modifications to approved set: upsize of system via addition of 4 modules.$0 plan check fee is due to Senate Bill SB-1222.  (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(19) TRINA SOLAR TSM255 MODULES(1) POWERONE TRANSFORMERLESS INVERTER)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47858	10041-10000-10865	770 W WILSHIRE BLVD GND & 3RD-FLOORS	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM			PC Approved	06/08/2010 12:00:00 AM	ADDRESS	34.04914	-118.25811	PARTIAL TENANT IMPROVEMENT ON 1ST FLOOR AND FULL FLOOR REMODEL ON 3RD FLOOR LEVEL OF (E) OFFICE BLDG.  (N) INTERIOR WALL, CEILING SYSTEMS, MILLWORK AND FINISHES TO RECONFIGURE OFFCE AREAS AND EXIT STAIRWAY DOOR ON 3RD FLR. PLAN CHK ISFO RTITLE 24 AND 3 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47859	14041-30001-34558	5100 W WILSHIRE BLVD 1-138	90036	4	132B181    39	5507026001	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			08/31/2016 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.06187	-118.34094	08-31-2016 Changes to an approved set of plans. Changes include reduce quantity of washer and dryer, and add loundry circuts on MSA, MSB, MSC, and MSC, add new panel and circuits on Panel HPG4 & HPG5 and add new lighting fixtures relocate circuits on some of the panels. Changes apply to Delta 2 only. Title 24 based on 2008 Code. Power plan check for new 7 story 138 unit apartment building.  New 5000 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47860	17041-10000-32081	510 S BROADWAY	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.04767	-118.25088	PC FOR FA IN COMM. BUILDING (5 STORIES) TOTAL 87 DEVICES AND 3 PANEL .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47861	10041-10003-17254	5300 N LANKERSHIM BLVD	91601	2	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Approved	06/02/2011 12:00:00 AM	ADDRESS	34.16715	-118.37571	"changes to permitted set of plans: on the first floor, added luminaires in lounge and in mens restroom ( installed lighting power is still less than what is allowed )on the second floor, relocated luminaires in the cycleoom and in the basketball room;relocated few outlets on the first floor ((((((((((((New occupancy in a commercial area.  New ""24Hour Fitness"".  Plan Check is for Power & Energy."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47862	19041-20000-12703	8124 N RHODES AVE	91605	2	189B165    55	2309002018	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	34.21846	-118.40294	PV1.  Install 8.10 kW roof mounted grid tied PV system and 9.8 kWh energy storage system.  (27) modules with 7.6 kW rated string inverter.Fees $37.99 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47863	18041-10000-46204	29050 S WESTERN AVE SUITE 113-123	90275	15	021B193    39	7445004242	(Q)C2-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	PIN	33.75477294	-118.30875089	PC FOR  ENERGY ONLY  FOR STORE TI. SCOPE INCLUDES COMBINING  5 RETAIL STORS INTO ONE AUTOZONE STORE WITH  NEW PANELS, EQUIPMENT,  CIRCUITS AND LIGHTS. TOTAL EFFECTED AREA IS 6257 SQ.FT (INDOOR+OUTDOOR)B#18016-10000-39040	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47864	16041-30000-34670	10100 W SANTA MONICA BLVD STE 1050	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for Title 24 only in existing office space in high-rise building STE 1001. Total area: 6,710 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47865	13041-10001-27903	10857 N RESEDA BLVD	91326	12	207B125    23	2717015005	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.26803	-118.53641	][][EXPEDITED PER APPLICANT REQUEST ][][]PV1, 7KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(28)modules: {TRINA SOLAR  {#TSM-250PA05.18}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP259-LV-MC4SM-2NA-Z}. (E) 200A MAIN. THE 250W OPTIMIZERS WILL BE CHARGED UNDER NON-DWELLING POWER EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47866	13041-10000-31156	7257 W SUNSET BLVD	90046	4	147B181   607	5548010022	C4-1D	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.09816	-118.3483	"FULL PLAN CHECK FOR EXISTING RALPHS STORE. INSTALLATION OF POWER AND LIGHTING INCLUDING REFRIGERATION FOR RALPH STORE. TOTAL ILLUMINATED INDOOR AREA IS 47602 SQ FT. (E) 2000A 277/480, 3PHASE, 4WIRE SWITCHBOARD. (1) NEW 225 PANEL ""NT""; ALL OTHER PANELS TO REMAIN. (1) NEW 75KVA STEPPED-DOWN XFMR (480V-3PH-3W PRIMARY, 120/208V-3PH-4W SECONDARY)."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47867	15041-10000-00876	923 W BLOOM WALK 212-213	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM			PC Info Complete	01/12/2015 12:00:00 AM	ADDRESS	34.0202	-118.28926	PC FOR ENERGY ONLY. (T24) PART OF USC BUILDING FOR LABORATORY. TOTAL AREA 971 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47868	14041-10000-03190	707 W WILSHIRE BLVD 23RD FLOOR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.04893	-118.2572	Tenant improvement for office suite in existing commercial highrise building.  Title 24 plan check for changes to interior lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47869	19041-30000-15937	10201 W PICO BLVD Bldg 103-5th Floor	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			Corrections Issued	04/30/2019 12:00:00 AM	ADDRESS	34.04994	-118.41129	Plan check for Title 24 only. Project site is a part of the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,845 sq. ft.Note: Building application has been generated under 19016-30000-12692	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47870	12041-20000-02288	21160 W CALIFA ST	91367	3	174B105    17	2149002019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.17691	-118.5929	T24 lighting plan check for shaker room: industrial work room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47871	16041-10000-00935	8117 S STEWART AVE	90045	11	099B161   758	4112019013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	33.96498	-118.40926	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.44KWac. (16)MODULES-SUNEDISON SEF270KZD(16)MICROINVERTERS-ENPHASE ENERGY M215-60-2LL-S2X	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47872	15041-10000-31522	601 W 5TH ST Ground FL	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.05049	-118.25386	T-24, TI TO AN (E) OFFICE  HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. PC FOR ENERGY ONLY. TOTAL SQ FT. 3585. RECEPTACLE UNITS PAID UNDER EXPRESS PERMIT # 15041-90000-30509.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47873	10041-20001-12295	8252 N VAN NUYS BLVD CVS-FUTRE TENT	91402	6	192B149   400	2212004001	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			Reviewed by Supervisor	05/13/2011 12:00:00 AM	ADDRESS	34.22127	-118.44856	Changes from previously approved plans.  Changes include relocate equipment and loads.  Plan check for power only.  Note: Approved plans submitted for reference only.*****PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT TO 3000A SERVICE.  NEW PANELS AND REVISED LOAD. PLAN CHECK ALSO INCLUDE POWER AND ENERGY FOR FUTURE TENANT (8248 VAN NUYS BLVD.) WITHIN CVS (WILL REQUIRE COMPLETE PLAN CHECK) MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47874	15041-10000-31645	1055 W WILSHIRE BLVD GND-3	90017	1	130-5A207 106	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.05232	-118.2629	Energy plan check for an office T.I . Scope includes new lighting and receptacles; total area is 1919-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47875	19041-20000-52609	4204 S GLENCOE AVE	90292	11	108B153  1222	4230006010	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	06/01/2022 12:00:00 AM	ADDRESS	33.98849	-118.44124	FULL PLAN CHECK, (4) PANELS, (31) BRANCH CIRCUITS, (6) EQUIPMENTS,(Building 1)1 OF 3 Electrical Application BLDG : 19010-10000-05843ELECTRICAL  FOR BUILDING 2: 19041-20000-52607ELECTRICAL  FOR BUILDING 3: 19041-20000-52578One Electrical permit shall be issued due to there is 1 building permit(06-01-2022)This is plan check only, Electrical permit covered under: 19041-20000-52578	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47876	11041-20000-20173	11922 W KLING ST	91607	2	168B165   746	2355015012	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Apartment			09/22/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.1557	-118.39292	Plan check for fire alarm panel replacement to existing system. Includes smoke detector.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47877	17041-10000-36036	8090 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	33.95166	-118.43325	INSTALL 28 NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47878	16041-30000-27693	601 S FIGUEROA ST 4590	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,135 sq. ft.Note: Building application has been generated under 16016-10000-16205	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47879	13041-10000-16310	516 N PALISADES DR	90272	11	129B117   107	4419015025	(Q)C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.04485	-118.55177	Retail TI for a new Starbucks store.  New 400 A electrical panel fed by shopping center distribution board, all new lighting and electrical work.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47880	14041-10000-25824	2914 W 8TH ST	90005	1	132B197   497	5077023015	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.05751	-118.28966	PLANCHECK FOR T24 ENERGY. TI FOR CHILDCARE CENTER (5,000 SF).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47881	13041-10001-14986	5817 S CRENSHAW BLVD	90043	8	108B185  1014	4005004020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	33.98847	-118.33114	SUPPLEMENTAL PC FOR ENERGY ONLY. LESS THAN 400A PER APPLICANT. fat burger buffalo cafe. ADDITITON OF LUMINAIRES IN INDOOR AND ADDITION OF OUTDOOR LIGHTING.PERMIT PREVIOUSLY PULLED UNDER 13041-20000-26592.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47882	17041-20000-43173	2230 S BEVERLY GLEN BLVD PV-1	90064	5	129B157   650	4315009022	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.04961	-118.41969	pv2install roof mounted pv system sized 20kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47883	10041-10000-11000	711 W FLORENCE AVE	90044	8	102B201   861	6013023900	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	06/20/2011 12:00:00 AM	ADDRESS	33.9748	-118.28617	Ti in a medical clinic. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47884	14041-10001-21142	3556 S SAWTELLE BLVD	90066	6	117B157   583	4249032043	R3-1	West Los Angeles	Palms - Del Rey - Mar Vista			2718.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	PIN	34.01546922	-118.42258736	EXPEDITED RSES PLAN CHECK PER APPLICANT.<<PV1, INSTALL 5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(20) MODULES: TRINA SOLAR TSM-255A05.18(1) INVERTER: SOLAREDGE SE5000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47885	15041-10001-09399	340 N AVENUE 51	90042	1	151-5A225 282	5469012001	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1835.20	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM			Corrections Issued	04/18/2015 12:00:00 AM	ADDRESS	34.10881	-118.20326	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47886	16041-20000-26474	6740 N ALLOTT AVE	91401	2	180B157    77	2329011007	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Closed	05/18/2018 12:00:00 AM	ADDRESS	34.19316	-118.42805	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47887	13041-10000-19168	2748 W 8TH ST 104-107	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			Reviewed by Supervisor	08/09/2013 12:00:00 AM	ADDRESS	34.05747	-118.28552	TENANT IMPROVEMENT. FULL PLAN CHECK. LIGHTING AND POWER FOR FAST FOOD RESTAURANT. 2 STORY BUILDING: WORK IS ONLY ON FIRST FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47888	15041-10000-43443	9510 S VERMONT AVE	90044	8	093A199    65	6039017075	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	33.94986	-118.29139	ADDITION TO EXISTING COMMERCIAL BLDG. ; new 1200A service and swbdNEW ADDITION DOES NOT HAVE BUILD-OUT YET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47889	18041-10000-11348	6757 W HOLLYWOOD BLVD #12	90028	13	148-5A185  92	5547011016	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			Corrections Issued	03/29/2018 12:00:00 AM	ADDRESS	34.10172	-118.33778	Change of Use of 275 sf of Retail space to a Take Out Restaurant and related TI.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47890	13041-10001-34370	18050 W OSBORNE ST	91325	12	195B125   194	2768005010	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.23346	-118.52661	Expedited RSES plan check per applicant request.{{{PV1, install 7.5 kw DC roof-mounted solar array for a 1-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE6000A-US. (30) modules: Renesola JC250M-24Bb.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47891	18041-20000-36244	15365 W VALLEY VISTA BLVD	91403	5	166-5A145 166	2283021016	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Issued	09/21/2018 12:00:00 AM	PIN	34.14955467	-118.46954436	Plan check for a PV1 roof-mounted PV system. System size is 1.74 kWac and consists of (6) modules and (6) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47892	13041-10002-01320	2500 S WESTERN AVE	90018	8	123B193   477	5058015005	C2-1, RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.03373	-118.30879	Plan check for power   Change of feeders from copper to aluminum, miscellaneous new loads, and (2) additional lighting fixtures (minor T24 changes).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47893	15041-20000-36289	21700 W OXNARD ST SUITE 1250	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.17901	-118.60179	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. HIGH RISE. SUITE 1250. 3336 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47894	15041-10000-39854	5353 S GROSVENOR BLVD	90066	11	105B161   730	4211006001	M2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM			PC Approved	11/25/2015 12:00:00 AM	ADDRESS	33.98293	-118.41421	PC FOR T24 ENERGY ONLY. NEW LIGHTING. INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT 15041-10000-42383.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47895	17041-20000-07366	301-319 N GLENDALE BLVD NORTH BLDG	90026	13	136-5A207 349	5159020024	C2-1VL	Central	Westlake	Greater Echo Park Elysian	Yes	2083.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Issued	09/12/2017 12:00:00 AM	ADDRESS	34.06582	-118.26051	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT AND SERVICE UPGRADE.  PART 2 OF 2SOUTH BLDG301-319 GLENDALE NORTH BLDG325-345 GLENDALE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47896	10041-10000-25770	940 W HARRY BRIDGES BLVD	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM			Verifications in Progress	04/04/2012 12:00:00 AM	PIN	33.77046453	-118.27163726	NEW GUARD HOUSE FOR PORT OF LA. EPC IS FOR POWER AND ENERGY. FIRE ALARM SYSTEM WAS SUBMITTED SEPARATELY.  (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47897	15041-20001-09662	1075 W CHILDS WAY	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.02304	-118.29105	10/05/2015 Changes to an approved set of plans. All changes have been clouded. Changes include the addition of equipment, revised panel schedules, and revised lighting. Title 24 Compliance Forms have been updated.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.   TENANT IMPROVEMENT FOR MARKS TENNIS STADIUM IN USC. 9750 SQFT INDOOR AND 5500 SQFT OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47898	16041-10000-23330	658 E VENICE BLVD PV-1	90291	11	108B145  1545	4237002006	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Issued	09/15/2016 12:00:00 AM	ADDRESS	33.98963	-118.46093	PV2 3PHASE SYSTEM ON EXISTING COMMERCIAL STORAGE BUILDING. TOTAL SYSTEM SIZE = 175KWAC. 663 MODULES AND 2 INVERTERS. FEED IN TARRIF PROJECT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47899	13041-20000-10190	21217 W SHERMAN WAY	91303	3	183B105    66	2112023010	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM			Corrections Issued	04/19/2013 12:00:00 AM	ADDRESS	34.20119	-118.59494	TENTANT IMPROVEMENT TO (E) RETAIL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47900	16041-10000-40333	1500 N EL CENTRO AVE 1ST & 3RD-Floor	90028	13	148-5A189 331	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.09917	-118.32359	Plan check for power and energy First time TI's for 1st  3rd floor of a commercial building. Total area: 19,105 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47901	12041-10000-17888	8900 N DE SOTO AVE B101-North	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.23162	-118.58832	New 3000A and 1200A switchboards, new substation and loads for an existing commercial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47902	15041-20000-18204	4070 S MARLTON AVE	90008	8	114B185   215	5032002048	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.01092	-118.33887	Plan check for Title 24 only renovate of the entire building and site for a new lightingfor new restaurant facility. Total area: 3,819 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47903	10041-10000-06679	2106 W TEMPLE ST	90026	13	136-5A205  32	5157017028	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.01	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM			PC Info Complete	06/22/2010 12:00:00 AM	ADDRESS	34.07024	-118.26853	TI in an existing AM/PM Store in an ARCO gas station. The TI area is in a general (Non Classified) area. . The applicant is requesting complete plan check of  Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47904	17041-10000-18165	6723 N VAN NUYS BLVD	91405	6	180B149   136	2236010001	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.19269	-118.44905	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL SPACE. SCOPE INCLUDES 48 FA DEVICES AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47905	14041-10000-26663	3183 W WILSHIRE BLVD	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM			PC Approved	09/26/2014 12:00:00 AM	ADDRESS	34.06196	-118.29111	Energy plan check for TI office in a commercial building. Replacing existing lighting with regular T8 lamp with dimming ballast. Total area is 1448 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47906	12041-10000-18607	1425 N SAN PABLO ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.06176	-118.20365	INTERIOR TENANT IMPROVEMENT TO EXISTING OFFICE SPACE (1,200 SQ FT) ON 3RD FLOOR FOR USC MEDICAL LABORATORY BUILDING.  LOAD IS LESS THAN 400 AMPS PER APPLICANT.  PLAN CHECK ONLY FOR ENERGY, WITH EMERGENCY LIGHTING.  PERMIT FEES ARE UNDER INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47907	14041-20001-02840	20601 W TIARA ST	91367	3	177B109   177	2151001005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.17722	-118.58179	(((expedite fees)))pv1 single family dwelling total system size 6kw ac using 24 modules. using transformerless inverter nonstandard plan. using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47908	16041-10000-37559	301 W OLYMPIC BLVD	90015	14	127-5A209 251	5139004026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.04182	-118.25852	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING RETAIL AND RESTAURANT MIXED USE BUILDING. SCOPE INCLUDES A 26 FA DEVICES, AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47909	16041-20001-05935	10614 W RIVERSIDE DR	91602	4	165B177   108	2423003029	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.15204	-118.36207	03/30/2016 Changes to an approved set of plans. Changes have been made to the lighting and power floor plans to reflect field changes. *****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial 2-story building. Project scope is a change of use from office to medical office and a tenant improvement. Total lighting area = 3,041 sq. ft.Note: Building permit has been pulled under 15016-20000-14297	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47910	18041-10001-43853	6150 N LAUREL CANYON BLVD C100	91606	2	177B165  1100			South Valley	NORTH HOLLYWOOD VALLEY VILLAGE			1239.01	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	"PLAN CHECK ONLY FOR CHANGES TO AN APPROVED SET. CHANGE INCLUDES CHANGE TO LIGHTING FIXTURE SCHEDULE, T-24, SINGLE LINE DIAGRAM AND PANEL SCHEDULE*****ORIGIANL PLAN CHECKER FRANCIES**********ORIGINAL SCOPE****PC FOR POWER AND ENERGY FOR A NEW ""TRADERS JOE'S"" IN A  SHELL SPACE. SCOPE INCLUDES NEW 800 A DISTRIBUTION SECTION 277/480 3PH, PANELS, EQUIPMENT AND CIRCUITS. TOTAL AFFECTED AREA 15920 SQ.FT INDOOR AND OUTDOOR   B#18016-30000-36766"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47911	13041-10001-36033	414 N AVENUE 61	90042	1	154-5A229 369	5484018020	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.11605	-118.19165	Expeddited RSES plan check per applicant request.{{PV1, Install 2.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (9) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47912	16041-20001-11036	13227 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.31115	-118.42909	8.30.2016 - Plan check for modifications to approved set. Service equipment is now new. Update single line to reflect. Update to series rating for panel branch circuits. Have emergency lighting on backup 3.75kW inverter instead of integral batteries on each fixture. Update some fixtures to equal or lesser wattage. Changes clouded delta 2 and 3.=====PLANCHECK FOR POWER AND ENERGY. TI FOR A HEALTH CLUB .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47913	19041-10000-49347	10419 N RESEDA BLVD	91326	12	204B125   636	2728025005	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.25975	-118.53636	(E-PLAN)NEW ROOF-MOUNTED PV1 INSTALLATION WITH AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES  30 MODULES (SPR-320E-WHT-D), 30 MICROINVERTERS (ENPHASE IQ7X), 1 POWER WALL, 1 COMBINER BOX, AND 1 PANEL OF 200 AMPS.SYSTEM SIZE: 9.6 kW DC; 9.45 kW ACFees $54.55 due to California Senate Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47914	11041-10003-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	33.94386	-118.4047	revisions to permitted set of plansbattery disconnects and grounding and lv control wiringMODIFICATION OF PREVIOUSLY APPROVED SET OF PLANS.  NEW EQUIPMENT, CIRCUITS AND PANELS.  CHANGES TO LOADS, FEEDERS  <<<<<core and shell plan review for the central utility plant at LAX airport>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47915	10041-20000-23937	6300 W WILSHIRE BLVD	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.06319	-118.36591	energy plan check suite # 715	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47916	19041-10000-49378	18141 W KNOLL HILL	91344	12	216B125   384	2601076001	RE20-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.28995	-118.52869	NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SYSTEM OF 400 AMPS. INSTALLATION INCLUDES 22 MODULES (XT-350R-AC), 22 MICROINVERTERS (IQ7PLUS-72-2-US), AND 1 COMBINER BOX.SYSTEM SIZE: 7.7 KW DC; 6.38 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47917	17041-10000-34701	1956 E 20TH ST	90058	14	118-5A215  82	5167006009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.0179	-118.23785	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM(180KVA) ON COMMERCIAL BUILDING. SYSTEM CONSIST OF 6 CENTRAL INVERTERS (SMA STP-3000TL), AND 512 MODUES (SPR-P17-345). PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47918	16041-10000-20596	1875 CENTURY PARK EAST STE 380	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	PIN	34.06139196	-118.41527843	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES ON THE 3RD FLOOR OFFICE SPACE. TOTAL AFFECTED AREA IS 2487 SQ. F.T	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47919	19041-10000-37447	1837 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	03/23/2020 12:00:00 AM		Issued	03/23/2020 12:00:00 AM	ADDRESS	34.04328	-118.37672	PC FOR ENERGY ONLY, SCOPE OF WORK IS CHANGE OF USE FROM DISCOUNT STORE TO AUTO PARTS STORE, SCOPE OF WORK INCUDES NEW LIGHTING, CONTROLS AND CIRCUITS.  TOTAL AFFECTED AREA IS 7475 SQFT. NOTE FULL PLAN CHECK MAY BE REQUIRED, SUBJECT TO FIELD INSEPCTION B#: 19016-10000-29569	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47920	14041-20001-03784	16025 W CIRCLE DIAMOND ROAD PV1	91342	7	228B141    66	2582033021	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.32431	-118.48038	][][ expedited per applicant request [][]PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL.6.75 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS, WITH (27) trina SOLAR #cs6p-250px, (27) OP300-MV, (1)6000A-US-ZB-U SOLAREDGE INVERTERS,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47921	11041-10000-26116	214 W 8TH ST	90014	14	127-5A211 175	5144016058	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM			Not Ready to Issue	12/09/2011 12:00:00 AM	ADDRESS	34.04329	-118.2542	T.I. to an existing retail space.  PLAN CHECK ONLY for Energy, no emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47922	15041-10000-32005	18654 W PARTHENIA ST	91324	12	195B121   416	2785002025	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM			PC Info Complete	09/28/2015 12:00:00 AM	ADDRESS	34.22809	-118.54008	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ND EMERGNCY LIGHITNG ONLY.  THIS IS PLAN CHECK ONLY.  PERMIT FEES PAID UNDER 15041-20001-00172.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47923	04041-10007-31759	1925 W WILSHIRE BLVD	90057	1	132A203    23	5142001022	C4-2	Central	Westlake		YES	2089.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.0574	-118.27431	REVISIONS ( DELTA   H )TO PERMITTED SET OF PLANS-ADDED 5KVA EM INVERTER WHICH IS TO BE SUPPLIED FROM PANEL HP; NEW EM LIGHTING CKTS; FEW LUMINAIRES WERE RELOCATED : FEW LUMINAIRES WERE ADDED; TITLE 24 REVISIONS WERE PLAN CHECKED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47924	13041-10000-29911	960 E 3RD ST	90013	14	127-5A217  90	5163016011	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.04578	-118.23289	Full plan check. Two story additon and interior renovation to an existing, two story professional school.  FA variance is filed,  Paint booth are listed by recognized testing laboratory. cra clearnce obtained under building permit 13014-10000-04395	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47925	13041-10001-33036	10658 N VANORA DR	91040	7	207B185   445	2547025003	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.26192	-118.32905	Expedited RSES plan check per applicant request.[][][]PV1, Install 2.75 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE3000A-US. (11) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47926	15041-10003-01354	200 WORLD WAY TERM 2-ARRI LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM			PC Approved	03/31/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Change to approved set by adding additional light fixtures and receptacle outlets; all changes are under delta-5 only.(((TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 ARRIVAL LEV 1  SPACE 283PLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47927	15041-10005-27142	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Info Complete	09/02/2016 12:00:00 AM	ADDRESS	33.93845	-118.42964	review changes to approved set of plans. changes noted delta 7 on plans. changes clouded. work include use of generator as optional standby. emergency lighting will be provided by branch circuit connected emergency inverters. inverter connection to generator will be considered powered by normal. ats is non required. provided new panels schedules and updated floor plans. rearrangement of circuits.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47928	14041-10000-05207	1724 S LIVONIA AVE	90035	5	129B169  1009	4305021005	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.04821	-118.38663	PV1, Install 4.5 kW DC roof-mounted solar array on a 2-story home, interconnect with EXISTING service panel. (1)Transformerless inverter: POWER-ONE AURORA PV1-3.6-OUTD-S-US-Z-A. (18) Modules: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47929	15041-20000-33942	11001 N SEPULVEDA BLVD	91345	7	210B145   300	2664012031	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM			PC Info Complete	10/13/2015 12:00:00 AM	ADDRESS	34.2697	-118.4673	TI, Full PC, power & Energy for Kaiser Permanente medical office, scope includes Blood draw room (1st fl) and exam room (2nd fl). Total area:891 sq. ft, all electrical equipment are existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47930	18041-20001-33752	927 S FEDORA ST	90006	10	132B197   978	5094022034	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	09/01/2021 12:00:00 AM	ADDRESS	34.05511	-118.29774	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. REDUCTION OF ELEVATOR MOTOR SIZE ON SINGLE LINE AND ADDITION OF A 30KVA TRANSFORMER AND INVERTER PANEL. CHANGES MADE TO SINGLE LINE LOAD CALCS AND MINOR CHANGES TO FLOOR PLANS.CLOUDED DELTA B CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47931	12041-10000-19947	8655 S SEPULVEDA BLVD	90045	11	096B165   768	4122001003	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	33.95844	-118.39645	Plan check power and energy. Existing building (retail core & shell electrical).  New 1200 Amp service, panels, lighting and loads for future tenant.  Variance to separate fire alarm system has been filed. Future tenant subject for complete plan review.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47932	15041-10000-04551	1411 S LAWRENCE ST	90021	14	120A215    22	5167017014	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.02462	-118.23725	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 6576 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47933	13041-10000-24535	1801 S HOPE ST	90015	14	124-5A205 177	5126011009	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM			PC Approved	09/09/2013 12:00:00 AM	ADDRESS	34.03479	-118.26899	TITLE-24 ONLY PLAN CHECK FOR A MORTUARY. TENANT IMPROVEMENT IS FOR A 1562 SF AREA IN A SINGLE-STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47934	14041-20000-07719	5701 N BECKFORD AVE	91356	3	174B117   188	2156005014	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.17439	-118.55161	PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 13KWAC.Note: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47935	13041-20000-22937	2929 N GLENDOWER AVE	90027	4	153B197   204	5588010032	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.11535	-118.29874	150KW OPTIONAL STANDBY GENERATOR FOR A NEW HOUSE. THIS PLAN CHECK COVERS GENERATOR AND TRANSFERSWITCH ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47936	17041-10000-40594	10250 W SANTA MONICA BLVD #1893	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space ""Malin + Goetz""  suite 1893"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47937	18041-10000-12924	7776 W FOOTHILL BLVD	91042	7	204B193   304	2558004016	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.25811	-118.30203	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47938	14041-20000-28810	4274 W SEA VIEW LANE	90065	1	151-5A221 244	5471002018	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.10913	-118.21946	STANDARD PLAN MICROINVERTERS SIZED 6.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47939	18041-10001-09965	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.12626	-118.21412	PLAN CHECK ONLY, SUPPLEMENTAL FOR LOST PLAN REPLACEMENTTHE PROPOSED PROJECT CONSISTS OF  A canopy  for 343 SF  OUTDOOR STORAGE AREA AT THE BIOSCIENCE BUILDIng and alterations inside nearby locker/dressing roomPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47940	19041-10000-46145	6121 W SUNSET BLVD	90028	13	147A189   234	5546026044	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Info Complete	11/08/2019 12:00:00 AM	ADDRESS	34.09818	-118.32309	T-24 ENERGY PC FOR REMODELLING OF A KITCHEN SPACE. SCOPE INCLUDES INSTALLATION OF NEW BRANCH CKTS AND LIGHTING EQUIPMENT. TOTAL AFFECTED AREA 544sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47941	13041-10001-32778	6100 N TOPANGA CANYON BLVD	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Expired	07/07/2016 12:00:00 AM	ADDRESS	34.18131	-118.60555	Delta 1;2;3 changes to permitted set of plans: main swbd bus is 2400A; FEEDER , 300KVA XFMR AND 1000A  TO INSTALL NEW EV CHARGING STATIONS; NEW CIRCUITS; AND STORAGE ENC;LOSUREALL CHANGES ARE CLOUDED ON REVISED SETS OF PLANSPLAN CHECK FOR POWER AND ENERGY FOR A 4 STORY OPEN PARKING STRUCTURE. WESTFIELD MALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47942	14041-10000-35575	13160 W RIVIERA RANCH ROAD	90049	11	132B137   174	4425025001	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM			PC Info Complete	02/17/2015 12:00:00 AM	ADDRESS	34.06037	-118.49606	Power plan check for a new house with new 600-Amp service.Separate permits for the feed barn and the stalls/stable	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47943	18041-20001-08084	22349 W ALGUNAS ROAD	91364	3	168B101  1032	2076018020	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.15257	-118.61527	08/02/2018 Changes to an approved set of plans. All changes have been clouded. Battery back-up interconnection configuration has been revised.*****Previous Work Description*****INSTALLATION OF ENERGY STORAGE SYSTEM TO EXISTING PV SYSTEM. SYSTEM SIZE: 27KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47944	19041-10000-29350	2500 W 7TH ST	90057	1	133-5A201 278	5141014001	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/21/2020 12:00:00 AM		Permit Finaled	05/06/2022 12:00:00 AM	ADDRESS	34.0583	-118.28122	Full PC for power only, service replacement for a new 800A service, this is phase 2 of a project. Phase one is already permitted under 19041-10000-19612	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47945	13041-20000-32025	8905 N GLENOAKS BLVD	91352	6	195B173   278	2408008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.23033	-118.36723	POWER AND ENERGY FOR NEW BANQUET HALL. RELOCATIONING 3 PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47946	15041-10000-23901	430 S BROADWAY	90013	14	129A211    57	5149024008	[Q]C4-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.04864	-118.24991	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS IN A SPRINT RETAIL STORE PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47947	12041-10000-09779	500 W WORLD WAY #5S	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM			PC Info Complete	08/03/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	New retail kiosk at LAX Terminal 5, Space 5S.  Full plan check for Power and Energy requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47948	19041-10000-48202	351 N AMALFI DR	90402	11	123B129   451	4410024011	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Expired	08/28/2023 12:00:00 AM	ADDRESS	34.03334	-118.51314	[EPLAN] ADDING 2 ESS (TESLA POWERWALL), 1 TESLA ENERGY GATEWAY, AND 1 GENERATION PANEL CONNECTED TO EXISTING SERVICE OF 200 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47949	19041-10000-12073	1801 S CENTURY PARK EAST STE 2200	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.06201	-118.41537	Tenant improvement to (E) office in suite #2200, Area 1,516 SF.  Installing New Lights.Bulding Permit: 19016-40000-07598	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47950	16041-10001-27162	11811 W SAN VICENTE BLVD	90049	11	129B145    52	4401017018	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.0532	-118.46895	PC for changes to approved set. Changes include alteration to receptacle and lighting layout and relocationof shade panels from roof to basement. Upsizing inverter panel from 3.8 to 5kW see note on single line diagram. All changes clouded under delta 12.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47951	19041-10000-14630	1494 N MORAGA DR	90049	5	147B145   212	4377039007	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.09492	-118.46897	PC for PV, system includes 66 modules (LG365Q1C-A5) W/Optimizers (solar edge-P370). (2) solar edge inveter ( SE10000H-US) and 1 new 200A sub-Panel. $0 fees due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47952	10041-10000-22200	114 S CENTRAL AVE	90012	9	129A215    84	5161018021	[Q]C2-3D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	01/18/2011 12:00:00 AM	ADDRESS	34.0487	-118.23901	Ti in an exixting restaurant. New 400A 3ph 120/240v 3ph service plan chk is for power and title 24. Note that gas seals for conduits to and frm UGPS are required as the site is  in methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47953	15041-10000-21758	8979 N WOODMAN AVE	91402	6	195B153   366	2639039021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	PIN	34.23251159	-118.4387642	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2302.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47954	17041-20001-12003	450 S OXFORD AVE	90020										Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	08/01/2017 12:00:00 AM	ADDRESS	34.06562	-118.30766	expeditepv2install roof mounted pv system sized 30kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47955	14041-20000-26060	1357 W AMAR ST	90732	15	018B193   117	7446004007	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	33.74769	-118.3055	PV1Install roof-mounted solar array, interconnect with MSP. System size: 5kW.(1) SolarEdge SE5000A-US transformerless inverter(20) SolarEdge P300 power optimizers(20) SMX-250-P pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47956	12041-20000-12956	13247 W PARKLAND CIR	91342	7	231B157   325	2582036013	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2012 12:00:00 AM			PC Approved	08/06/2012 12:00:00 AM	ADDRESS	34.32646	-118.42146	Enphase P.V. system on roof of single family dwelling.Note: Permit issued under 11041-20000-26337	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47957	18041-20000-11686	4257 N NOELINE AVE	91436	5	165B137   273	2284019009	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.14852	-118.48753	battery back up system 16KWh to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47958	17041-20000-38690	10948 N OSO AVE	91311	7	210B113   138	2707031008	(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.26913	-118.57623	installation of (1) tesla power wall to an existing pv system.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47959	13041-10000-06908	11840 N BALBOA BLVD	91344	12	216B133   583	2610002005	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM			PC Approved	03/18/2013 12:00:00 AM	ADDRESS	34.28508	-118.50187	PC FOR ENERGY ONLY. LIGHTING CHANGE TO LEDs. MCDONALDS. ADDITION OF 192 sq. ft. to the dining room and 125 sq. ft. to the kitchen area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47960	17041-20000-17959	11819 W WILSHIRE BLVD	90025	11	129B145   758	4265013087	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM			Verifications in Progress	05/23/2019 12:00:00 AM	ADDRESS	34.04794	-118.46302	Improvements to (E) commercial parking garage and shopping center outdoor lighting.  Plan check for power and energy.  building permit # 17016-10000-13791	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47961	17041-10001-08898	680 W KNOX ST #125	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	04/19/2017 12:00:00 AM	ADDRESS	33.85408	-118.28767	LIGHTING, PLUGS AND SWITCHES FOR REMODEL. PC FOR T24 ENERGY ONLY. THIS IS PC ONLY - PERMIT ALREADY ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47962	13041-10000-04150	16622 W CALAHAN ST	91343	12	198B137   920	2687024013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.23655	-118.49456	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. SINGLE STORY DWELLING WITH DETACHED GARAGE. TOTAL SIZE OF 5KW. 18 MODULES. TRANSFORMERLESS INVERTER. PER SUPERVISOR REQUEST, BACK ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47963	18041-20000-22139	1025 W 34TH ST 2ND FLOOR	90731	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.02471	-118.28835	Plan check for Title 24 Energy only in existing building USC office T.I. new lighting and receptacles 2nd Floor. Total area: 3860 sq ft.B#18016-10000-17939	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47964	18041-20000-19619	3434 S GRAND AVE CAL 153-154	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.01912	-118.27658	Plan check for Title 24 Energy only in existing Carol Little Building(CAL) in room 153 and 154 training roomsrenovation. Total area: 1900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47965	13041-10000-00759	2525 S CENTRAL AVE	90011	9	118-5A209 348	5131026029	C2-1, [Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			01/11/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.01913	-118.25505	First time tenant general lighting and general wiring for retail space	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47966	17041-10000-16883	730 S SERRANO AVE 1-28	90005	10	132B193   438	5093014020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			05/19/2017 12:00:00 AM			PC Info Complete	11/01/2017 12:00:00 AM	ADDRESS	34.05884	-118.30642	Power plan check for energy only.  Service upgrade to new 1200A service for existing 28 unit apartment building.  Combine 2 units into 1, add 9 single units, and remodel 4 existing units.Building permit #17016-20000-02430	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47967	18041-10003-06179	1925 S TUDOR LANE	90034	10	126B173  3095	6207036031	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM			Reviewed by Supervisor	02/28/2018 12:00:00 AM	ADDRESS	34.04074	-118.37113	PC for Tesla powerwall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47968	18041-10000-32914	725 S FIGUEROA ST # 2150	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	REMODELING IN OFFICES SUITE 2150PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47969	16041-10002-06191	12775 W MILLENNIUM #135	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM	ADDRESS	33.97584	-118.4171	06/13/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE MADE UNDER DELTA 7 AND DELTA 8. SCOPE INCLUDES ADDING/REMOVING LIGHTING FIXTURES. CONTROL CREDIT FOR LIGHTING FIXTURES HAS BEEN UPDATED. NOTE: PERMIT PULLED PCIS#16041-10000-06191(((((T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO NEW FITNESS/GYM. TI TO AN EXISTING COMMERCIAL BUILDING (FITNESS CENTER). SCOPE INCLUDEW NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3,400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47970	15041-20001-09932	18241 W CHATSWORTH ST	91326	12	207B125   264	2715009014	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM			PC Approved	04/15/2015 12:00:00 AM	ADDRESS	34.26468	-118.53073	Supplemental application for expedite fees.Installation of new roof mounted solar PV array.  Total system size = 5.59 kWac.  Microinverter system with 26 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47971	16041-20000-08822	7071 N VINELAND AVE	91605	2	183B173   142	2319002018	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Issued	03/15/2016 12:00:00 AM	ADDRESS	34.19929	-118.37051	Plan check for power for pre-fab equipment: spray booth, industrial ovens, blasting room inside existing commercial building.  Hazardous classification around spray booth.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47972	15041-20000-02776	12476 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	33.97888	-118.41041	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47973	16041-10000-44623	200 N SPRING ST STE 220	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.05405	-118.24317	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE/WAITING SPACES FOR SUITE 220. TOTAL AFFECTED AREA IS 2926 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47974	19041-10000-15388	18300 W PARTHENIA ST	91325	12	195B125   845	2786001034	M1-1VL, PF-1XL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Issued	04/26/2019 12:00:00 AM	ADDRESS	34.22855	-118.53232	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47975	19041-10000-37134	10209 N SAMOA AVE #1-11	91042	7	204B197   939	2565015065	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1012.10	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM	05/24/2021 12:00:00 AM		Issued	05/24/2021 12:00:00 AM	ADDRESS	34.25442	-118.28745	FULL PC FOR A NEW 3 STORY APARTMENT WITH 11 UNITS. SCOPE OF WORK IS A NEW 800A (3P, 4W) SERVICE, TWO DISTRIBUTIONS BOARD, A HOUSE BOARD RATED AT 400A AND THE RESEDITINAL BOARD RATED AT 600A. TOTAL AFFECTED AREA IS 11,942 SQFT.  B#: 18010-10000-04255	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47976	12041-10000-30842	7083 W HOLLYWOOD BLVD 600	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM	12/24/2012 12:00:00 AM		Permit Finaled	02/04/2013 12:00:00 AM	ADDRESS	34.10173	-118.34439	t24 for highrise. ti for emergency lighting system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47977	14041-10000-08555	12501 N GLADSTONE AVE #A-5	91342	7	219B161   211	2525018061	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.29709	-118.41363	Title 24 only. Remove HID light fixtures and replace with new fluorescent fixtures. Total area 8720 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47978	17041-20003-36046	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM			PC Approved	02/21/2018 12:00:00 AM	ADDRESS	34.24912	-118.34256	Revisions to approved set.  Miscellaneous wiring changes.  $0 plan check fee per State Senate Bill SB 1222.(((01/18/2018 Changes to an approved set of plans. All changes have been clouded. Changes include the removal of the Tesla PowerWall from the PV system.Plan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.5.2kW unground pv system. (21) 315W pv modules. (1) 5kW Tesla Powerwall 2.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47979	13041-10000-03947	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.0346	-118.45665	PERMIT TO BE ISSUED BY PC ONLY PC FOR ENERGY ONLY. TI TO EXISTING BLDG (RESTROOMS AND OUTDOOR LIGHTING). LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47980	19041-10000-29980	1150 S HOPE ST	90015	14	126A207    58	5139021001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.04097	-118.26403	SERVICE UPGRADE TO 600 AMP AND INSTALLING 2 NEW 75 KVA TRANSFORMERS AND PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47981	18041-20000-06698	2601 N BOWMONT DR	90210										Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM	ADDRESS	34.11604	-118.39984	new sfd 2000 amp service.  plan check for power only. distribution board for home = 800Asee comments...........	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47982	15041-10000-07588	2556 E OLYMPIC BLVD	90023	14	120A219     8	5169015007	M3-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.02532	-118.2241	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACE HID LIGHTING FIXTURES WITH NEW LEDS.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 22586	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47983	18041-10003-09709	931 W OXFORD AVE	90292	11	105B149   457	4229002013	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	33.98604	-118.44881	Revision to approved set of plans.  Change of location of energy storage batteries and AC disconnects to the exterior of the single family dwelling.  Note: Permit is paid under PCIS#18041-20000-09709	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47984	14041-20001-13710	18341 W LAKE ENCINO DR	91316	5	165B125   397	2184041032	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.14564	-118.53082	PC FOR PV SYSTEM. USING MICROINVERTER ENPHASE M250. USING STANDARD PLAN. TOTAL OF 42 MODULES. SYSTEM SIZE 10.5 KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47985	13041-20000-04903	16701 W MARQUEZ TER PV-1	90272	11	129B121   607	4419014007	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.04824	-118.5453	PV-1. MIcroinverter standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47986	15041-20001-12630	1440 S VETERAN AVE	90024	5	129B153    17	4324038***	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			09/14/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	34.05284	-118.44327	Changes to an approved set of plans. Moving location of emergency lights.Plan check for T-24 only. Remodel the common area in The Colony. Total area: 3,327 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47987	12041-10004-27063	8500 W BURTON WAY SUITE 200	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM			PC Approved	04/24/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	(((Revision to supplemental 10003 Title 24 Part 6 plan check.  6 new incandescent pendant chandeliers added.  Each fixture is to have max 4 x 40 W incandescent bulbs installed.   UL listing of custom fixture to be verified in field.))) TI TO RESTAURANT PART OF THE crusoe project approved per mehdi . not a high rise . 1799 SFDELTA 6 CHANGES TO THE APPROVED PLANS.     CONDITION WAIVED PER BEHZAD BY MEHDI 10/22/2012 (((((((((((((( cHANGES MADE TO PREVIOUSLY APPROVED SET, ADDITION OF 15HP  FIRE PUMP AND 3/4 HP JUCKY PUMP, CONVERSION OF TWO UNITS TO ONE PENT HOUSE, RELOCATING PANEL, LOAD CALS )))))))))))))))))(((((((((((( Revision to previously approved set , change of out door and indoor lits and title 24, new added ckts, relocation and reckting..  8-9-12  ))))))))))))))))))))))))New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47988	17041-10000-23334	11401 N PORTER RANCH DR BLDG 4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 41 unit apartment with 1600 amp 208 volt service.       Building 4 of 10.  Type IV.       Building permit #17010-10000-02381	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47989	16041-10000-34481	10250 W SANTA MONICA BLVD # 1875	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Aveda"" Ste. 1875.  Install new transformr, panels and its circuits, lights and receptacles. Total effected area: 682 sq.ft. T-24 using performance method."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
47990	19041-20000-34929	9237 N WAKEFIELD AVE UNIT# 11	91402	6	198B149   619	2639008018	(T)(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.23831	-118.44831	Plan check for PV roof mounted system, PV system size: 3.78KW with 12 PV Modules and 1 inverter(3.8KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
47991	11041-10000-26895	927 S ARDMORE AVE	90006	10	132B193   999	5093023032	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2124.20	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	34.05495	-118.30211	New 6.3KW, rooftop, photovoltaic system for a single family residence.  And new 200A service.  One inverter and 33 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47992	18041-20002-11203	16444 W ROSCOE BLVD	91406	6	189B137     4	2205003906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.21987	-118.49574	18041-20002-11203SUPPLEMENTAL TO CHAGES TO APPROVED SET OF PLANS TO INDICATE CONDUCTORT SIZING FROM WEATHERHEAD TO TEMPORARY SERVICE (TPSB) - CHANGE IS NOTED UNDER DELTA 318041-20001-11203SUPPLEMEMNTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES NOTED UNDER DELTA 2 INCLUDING DISTRIBUTION BOARD TO MATCH FIELD CONDITIONS AND DWP SERVICE LETTER OF 600A, AND DECREASE CONDUCTOR SIZING FOR TRANSFORMER(LUGS TO BE RATED AT 75 DEG. C. MIN.)18041-20000-11203PLANCHECK FOR POWER. TEMPORARY POWER FOR AIRPLANE HANGAR. 600 AMP SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47993	19041-10000-30858	9200 N DEERING AVE	91311	12	198B105   115	2746010034	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.23783	-118.59594	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47994	18041-10000-08789	1875 CENTURY PARK EAST 17TH FLR	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			PC Info Complete	03/09/2018 12:00:00 AM	PIN	34.06139196	-118.41527843	T-24, PC FOR ENERGY ONLY. T.I. FOR AN  OFFICE SPACE.  SCOPE INCLUDES NEW LIGHTS FOR EXISTING OFFICE SPACE ON THE 17TH FLOOR. TOTAL AFFECTED AREA IS 16026 SQ. FT. B#18016-10000-02649	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47995	17041-20000-32395	620 S UNION AVE	90017	1	132A205   143	5142028031	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Issued	12/27/2017 12:00:00 AM	ADDRESS	34.05638	-118.26929	PV2.  Install 209.39 kW AC roof mounted grid tied PV system.  (7) 36kW rated transformerless string inverters.  (762) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
47996	11041-20000-04294	6105-6107 N CLYBOURN AVE Office-Lndry Bldg	91606	2	177B177   374	2414021021	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Apartment			03/07/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Issued	06/01/2011 12:00:00 AM	ADDRESS	34.18147	-118.35936	Plan check for Office/Laundry Building power supplied from Building 6. This application is part of #11041-20000-04291	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
47997	13041-10000-06149	411 N CENTER ST	90012	14	130-5A217 273	5173016008	M3-1	Central	Central City North	Historic Cultural		2060.30	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.05134	-118.23172	permit issued by this applicationti of industrical space for office and restroom/support areas. total area 946 sq ft.  PC FOR T24 ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47998	17041-10000-05480	3229 W CASITAS AVE	90039	13	153B209   518	5436002027	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.11548	-118.25102	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR) 28750 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
47999	17041-10000-02013	14057 W HERRON ST	91342	7	222B153   492	2508005007	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.30369	-118.43969	PC FOR PV SYSTEM. USING 2 CENTRAL INVERTERS AND 39 MODULES. SYSTEM SIZE 12.7KW AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48000	19041-20000-01383	4450 N CALLADA PL	91356	3	165B121    29	2177012027	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.15252	-118.54259	Plan check for a PV1 roof-mounted PV system. System size is 10.9 kWdc/10.79 kWac-CEC and consists of (1) 10 kWac rated inverter and (37) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48001	18041-20000-44443	5401 N SEPULVEDA BLVD BLDG B	91411	4	172-5A145  22	2250001020	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	34.16854	-118.46653	PV2.  Install 53.95 kW roof mounted grid tied PV system.  (166) modules with (4) 11.4 kW rated string inverters.  System 1 of 2.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48002	19041-20000-52869	10636 W ROCHESTER AVE	90024	5	132B153   451	4326015035	R1-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.05825	-118.4335	Plan check  for PV roof mounted system, PV system size: 8.4KW with 23 PV Modules and 23 Micorinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48003	12041-10000-17874	1959 N MANDEVILLE CANYON ROAD	90049	11	138B137   565	4492002012	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM	09/06/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.0704	-118.49701	New 5.87kw rooftop mounted photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48004	10041-10000-22413	12811 W SHERMAN WAY	91605	2	183B161     9	2324005033	C2-1VL	South Valley	North Hollywood - Valley Village			1233.03	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.20135	-118.41209	CHANGE FROM  AN EXISTING SEAFOOD MARKET TO A GROCERY STORE FRESH AND EASY STORE ).  SCOPE OF WORK TO INCLUDE INTERIOR REMODEL, MINOR SITE OWRK, LANDSCAPING AND EXTERIOR ELEVATIONS REMODEL, RESTRIP EXISTING PARKING.  ADDITION OF MEZZANINE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48005	18041-20000-43972	1055 W 7TH ST Suite 100	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.0507	-118.26334	Plan check for Title 24 only. Project site is the 1st floor of an existing commercial high-rise. Project scope is a tenant improvement. Total lighting area = 3,289 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48006	16041-20000-21559	18226 W VINTAGE ST	91325	12	204B125   358	2731023018	RA-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Expired	07/26/2018 12:00:00 AM	ADDRESS	34.25167	-118.53075	PV1.  Install 6 kW roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48007	16041-20000-38620	10265 W WOODBRIDGE ST	91602	4	165B177   517	2424022011	RE11-1-H-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM			PC Info Complete	12/14/2016 12:00:00 AM	ADDRESS	34.14859	-118.35475	Plan check for power only. Project site is a new single-family home with an accessory living quarters.Note: Building applications have been created under 16010-20000-03693 and 16010-20000-03694.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48008	13041-10000-30926	10055 N WOODLEY AVE	91343	12	204B141   806	2678010012	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.25353	-118.48509	PV1.  Install 9 kW DC roof-mounted PV system on 1-story house, interconnect with main service panel.  Transformerless inverters: SolarEdge SE5000A-US and SE3800A-US.  36 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48009	17041-10000-30270	10701 W VENICE BLVD	90034	5	117B161   337	4252030043	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.0188	-118.40732	Energy plan check for removing HID fixture and replacing with new LED fixture. Total area is 9050 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48010	19041-10000-04326	2502 S FIGUEROA ST	90007	9	121-5A203  24	5124027017	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.02877	-118.27536	PLAN CHECK FOR TITLE 24 ONLY FOR - CHANGE OF USE FROM (E) RETAIL TO (N) RESTAURANT. TENANT IMPROVEMENT INCLUDING NEW NON BEARING PARTITIONS, MILLWORKS, FINISHES. ENTERPRISE ZONE, NO CHANGE IN PARKING. - TOTAL AFFECTED AREA 2507 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48011	17041-10000-38950	1128 N HYATT AVE	90744	15	033B209   538	7423027058	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			Reviewed by Supervisor	11/07/2017 12:00:00 AM	ADDRESS	33.78589	-118.25403	Install new 5kW AC rooftop solar system, and 13.5 kWh ESS on a SFD.(20) modules with (20) optomizers, (1) inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48012	18041-10000-48931	1247 W MANCHESTER AVE	90044	8	097-5A197 306	6033013039	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.96018	-118.29741	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48013	10041-10000-01798	3655 S GRAND AVE	90007	9	118-5A203 278	5122023028	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM			PC Info Complete	02/18/2010 12:00:00 AM	ADDRESS	34.01726	-118.27819	"ALTERATION FOR EXISTING ROOF SIGN AT SAME SIZE & LOCATION, REFACE WITH NEW METAL PANELS FOR ""MERCADO LA PALOMA"" ( 10041-10000-00126) ; ALSO, NEW LUMINAIRES FOR EXISTING WALL SIGN ( 10048-10000-00125). PLAN CHK IS FOR TITLE 24 COMPLIANCE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48014	18041-20000-47001	14255 W DEARBORN ST	91402	6	198B153   810	2639028015	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.23725	-118.44407	PV1.  Install 12.540 DC kW roof mounted grid tied PV system.  (38) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48015	19041-10000-42804	2001 E 7TH ST	90021	14	124-5A217 238	5164020011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	06/05/2020 12:00:00 AM		Permit Finaled	03/23/2023 12:00:00 AM	ADDRESS	34.03474	-118.23211	FULL PLAN CHECK FOR A FRST TIME TENNANT, SCOPE OF WORK INCLDUES NEW CRICUITS POPULATING EXISTING PANELS ALL CONNECTED TO AN EXISTING 800A SERVICE (120/240 3P,4W), TOTAL AFFECTED AREA IS 6957 SQFT . NOTE ALL SUB PANELS ALONG WITH THE SERVICE WERE APPROVED UNDER 19041-10K-20938. THIS PERMIT COVERS THE TI ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48016	16041-20001-18000	22741 W VICTORY BLVD	91307	12	180B097   546	2038038021	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM			PC Approved	09/06/2016 12:00:00 AM	ADDRESS	34.18663	-118.6225	9.6.2016 - Plan check is/was Title-24 only, and there were no changes to the lighting system. Applicant requested restamp of plan due to removal of electric vehicle chargers and panel HC from the plan. =======PLANCHECK FOR TITLE 24 OUTDOOR LIGHTING ONLY.  FALLBROOK SHOPPING CENTER. 5850 SQFT	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48017	15041-10002-10802	555 W REDONDO BEACH BLVD	90248	15	072B201    97	6120028006	C1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	33.89286	-118.28458	Changes to approved set: relocation and slight changes to types/layout of devices to accommodate architectural layout changes.  (((Change to approved set by adding (58) fire alarm devices and power supply on the floor plan.)))  (((FIRE ALARM FOR 2 STORY(E) BUILDING. 99 FIRE ALARM DECIVES, 1 CONTROL PANEL AND 1 FIRE ALARM PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48018	16041-20001-00123	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.97615	-118.42138	(10/19/2016)changes to an approved set of plans.  changes noted delta 10.  changes include new energy management system, new panels and circuits.  PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENTS FOR OFFICE BUILDING, GROUND FLOOR AND MEZZANINE.Note: Building application has been submitted under 15016-10000-25133	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48019	16041-10002-28989	2005 W PICO BLVD	90006	1	129A201   230	5136023031	(Q)CM-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.04702	-118.28177	03/23/17Changes to approved set of plans. All changes are clouded under delta 2. Changes include relocating inverter on the roof-layout, and revising single line diagram to reflect what is on the field.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48020	13041-10000-27361	2650 W TEMPLE ST	90026	13	138A203   249	5156027010	C2-1	Central	Westlake	Greater Echo Park Elysian		2086.20	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			Corrections Issued	10/11/2013 12:00:00 AM	ADDRESS	34.07272	-118.27566	TITLE-24,PART6,EXTERIOR LIGHTING FOR 6 WALL MOUNTED LIGHTS, (2) BIG SIGNS(15' X 6'), (5) SMALLER SIGNS (7' X 3') .  RETAIL SPACE, SHOPPING CENTRE. CKT 1 FOR (6)WALL MOUNTED LIGHTS, CKT 2 FOR (2) BIG SIGNS, CKT # 3 FOR (5) SMALLER SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48021	16041-10000-07180	7349 N TOPANGA CANYON BLVD	91303	3	186B101   694	2023005012	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.20429	-118.60619	FULL PC FOR POWER AND ENERGY FOR A COMMERCIAL BUILDING. CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE. TOTAL AFFECTED AREA IS 972 SQ. FT.NOTE: PERMIT PAID UNDER PCIS#16041-70000-37298	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48022	18041-20000-40091	17536 W MELVILLE PL	91344	12	219B129   311	2608011024	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.29794	-118.51604	pv1install roof mounted pv system sized 10.4KW AC interconnected with msp.CEC system size 8.0686KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48023	13041-10000-28836	380 WORLD WAY T22-FB	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	FIRST TIME TENANT. POWER AND ENERGY PLAN CHECK. LAX BRADLEY TERMINAL. MASTER PLAN CONNECTED LOAD 72.80 KVA @ 480/277. LOAD FROM 3N1BC1 : 175.57 KVA @ 480/277. 3NMBC1 @ 306.58 KVA @ 480/277. FEES SHALL BE VERIFIED BY PLAN CHECKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48024	14041-10001-24953	3508 S ENVILLE PL	90016	10	120B173   462	5047002036	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.02288	-118.36998	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 3.315 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(13) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: POWER-ONE PV1-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48025	12041-10000-26873	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Approved	11/08/2012 12:00:00 AM	PIN	34.05182951	-118.41257696	Ti in an existing office BLDG. EPC is for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48026	15041-10000-17071	12508 W OSPREY LANE #3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			PC Approved	06/03/2015 12:00:00 AM	ADDRESS	33.97856	-118.41138	PV2 INSTALL ROOF MOUNTED PV SYSTEMFOR UNIT 3 SIZED 2.76KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19577	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48027	13041-20000-34603	900 N WESTERN AVE	90029	13	141B193   110	5535020011	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.08641	-118.30895	PC FOR T24 ENERGY ONLY. EXISTING OFFICES, NEW LIGHTING. LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48028	17041-20001-32508	8107 N ALDEA AVE	91406	6	189B133   170	2204009030	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.21758	-118.50894	[[ One time exception; Changes to approved online PV permit. Delta 1 changes. Plancheck Only to change to center fed panel interconnection. Derating main breaker to 150Amps, Service load calculation provided]]]]]Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48029	17041-10003-12815	380-384 WORLD WAY MSC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to apprpoved set of plans. Changes are noted under DCN-097 and DCN-098, delta number is correlated to these DCN on affected sheets. Scope consists of loads/circuits modification related to power and lighting circuits, adjusting panel schedules, load calculation, and floor plan accordingly. T24 information is to remain unchanged	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48030	19041-10001-50286	8020 W MANCHESTER AVE	90293	11	096B153   618	4118002101	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM			PC Approved	03/04/2020 12:00:00 AM	ADDRESS	33.95927	-118.43572	Expedite per applicant request Plan check for a 86.4 KW AC/ 107 KW DC roofmonted system. Scope includes (2) inverters, (246) modules and optimizer interconnecting through a load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48031	13041-10001-23061	11431 N LEMONCREST AVE	91342	7	213B177   177	2529008013	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.27728	-118.35734	"""PLAN CHECK EXPEDITE PER APPLICANT REQUEST"" *********************************************PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. MICROINVERTER SYSTEM ON A NON STANDARD PLAN. [MODULES: TRINA SOLAR # TSM-250PA05.08 |||| INVERTER: ENPHASE ENERGY # ENPAHSE M215-60-2LL-S22] SYSTEM SIZE IS 7.095 KW AC AND 8.25 KW DC."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48032	16041-10001-09451	222 N PARK VIEW ST	90026	13	136-5A205  23	5157012008	RD2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			06/21/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.07029	-118.27229	06/21/16Changes to an approved set of plans. All changes are clouded under delta A.  Changes include relocating the inverter on the site plan and adding an additional AC disconnect.  Note: permit is pulled under PCIS#16041-10000-09451((((PV2, rooftop solar installation under 4 unit (multifamily) dwelling. 3kW system.    (9) KU2656ZPA      (1) PVI-3.0-OUTD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48033	16041-10001-00572	1318 E 7TH ST	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM			PC Approved	08/10/2016 12:00:00 AM	ADDRESS	34.03608	-118.24052	Note changes delta 2. Change to medium voltage cable size. contractor taking design responsibility for delta 2 changes onlyPC FOR POWER AND ENERGY TO TWO BUILDINGS SERVED BY A SINGLE SERVICE. SCOPE INCLUDES  ADDING 4 NEW MEDIUM VOLTAGE SUBSTATION UNITS, AND NEW DISTRIBUTION EQUIPMENT. TOTAL AFFECTED AREA IS 14,003 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48034	15041-10000-28085	4226 E VERDANT ST	90039	13	159B205   455	5594006029	[T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.13138	-118.26456	Full plan check for a new SUNDAY SCHOOL, CLASSROOMS, MULTI-USE BUILDING ACCESSORY TO CHURCH BUIDING. Scope include (1) 3000-Amp 480/277V 3-phase service, (11) panels with (183) circuit and total of 48,136-SQ feet for T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48035	11041-10000-18538	600 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM	08/31/2011 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	CONVEYOR BELT SYSTEM FOR ALASKA AIRLINES, TERMINAL 6, LAX.  18 NEW PANALES. THIS PERMIT IS TO COMBINE THE PERMIT # 11041-10002-04160 WHICH WAS APPROVED FOR UPDATING THE SLD. AND PERMIT # 11041-10000-08338 WHICH WAS APPROVED FOR CONVEYORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48036	14041-10000-17469	3040 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.01637	-118.21457	Plan check for power and energy.  Total area = 17,060 sq. ft.Installing electrical for coolers in existing commercial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48037	14041-10000-32154	840 S ALVARADO ST	90057	1	130-5A203  50	5141020007	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.05355	-118.27845	PROPOSED CHANGE OF USE FROM FOOD MARKET TO RETAIlNEW LOAD IS LESS THAN 400APLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48038	17041-20001-14347	8110 N LANKERSHIM BLVD	91605	6	189B169    62	2311005040	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	PIN	34.21795078	-118.38731326	[[[[7/10/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ONLY. CHANGING PANEL A  AND B FEEDER AND BREAKERS. INDICATING SERVICE FEEDER SIZES ON THE PLANS]]]]]PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 600 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48039	10041-10000-17591	1238 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04998	-118.22617	Solar voltaic system installed on the roof of the building.  Consists of  7 modules,  7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48040	14041-20000-08944	2909 W RODIN PL	90065	14	160-5A219  77	5683040021	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.1352	-118.22747	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48041	13041-10000-07123	425 S SOTO ST	90033	14	126A223    76	5183014036	C2-1, P-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.0398	-118.21254	RENOVATION OF EXISTING GROCERY STORE. NEW LIGHT FIXTURES AND CHANGE IN PARTITIONS OF AREAS. TOTAL AREA 17041 SQ FT. PC FOR ENERGY ONLY T24. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48042	14041-20000-15815	9268 W ROBIN DR	90069	4	147B169   191	5561006015	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			Reviewed by Supervisor	06/24/2014 12:00:00 AM	ADDRESS	34.10121	-118.39137	Plan check for power only. New 2-story 17,542 sqft SFD. this is plan check only. permit fees collected by building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48043	19041-20000-30990	3291 W ROMULUS DR	90065	14	160-5A215  39	5679006023	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.1344	-118.23562	PV1.  Install 5.67 kW roof mounted grid tied PV system with 13.5 kWh energy storage system.  (18) modules with 5 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48044	14041-10000-00748	1458 S SAN PEDRO ST #L-36	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in Fashion District retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48045	16041-20000-23075	5665 N RHODES AVE	91607	2	174B165   492	2340017014	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.17399	-118.40322	PV1.  Install 15.04 kW roof mounted PV system.  (46) modules, (1) transformerless 11.4 kW inverter, (1) 5 kW inverter, and power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48046	15041-20000-00485	1200 W 7TH ST 5TH FLR	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.05136	-118.26616	TI TO AN EXISTING HIGH RISE OFFICE BUILDING. ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED ON THE 5TH FLOOR ONLY.  TOTAL SQUARE FOOTAGE 35,940.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48047	19041-20000-22139	1323 S ORANGE GROVE AVE	90019	10	129B177   233	5086004029	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			06/11/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.05256	-118.36538	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN NEW 5-STORY APARTMENT BUILDING. SCOPE OF WORK INCLUDES (370) FA DEVICES AND A FIRE ALARM PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48048	11041-10001-21206	10000 W PICO BLVD BLDG 1	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/17/2012 12:00:00 AM	ADDRESS	34.05211	-118.40654	Delta 4 revision to approved plans. Revision consist of changes to lighting and provide methane mitigation if installation penetrates hazardous area. BLDG. NO. 1(Pool equipment section inc. outside lighting) OF POOL HOUSE AT THE HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDG. NO. 1, 2, 3, & 5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48049	19041-20000-13387	5900 W WILSHIRE BLVD Ste 750	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48050	15041-20000-14452	22547 W GILMORE ST	91307	12	180B097   476	2038039007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.18788	-118.61857	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Two inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48051	15041-20000-37282	1745 E 7TH ST	90021	14	124-5A215  58	5164022001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.0349	-118.23475	Full PC. Convert a warehouse/storage building to parking at basement and at portion of the first floor, a 6000 sf commercial/retaurant space on the first floor, and 57 live work units.  Scope of work also included an addition of a two-level parking garage on west side of the existing building with one level at the basement. There are 23 typical units. Total area: 41839 sq.ftNote: Building application has been created under 15014-10000-00129	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48052	16041-30000-25404	6908 S KNOWLTON PL	90045	11	102B173   275	4103013104	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	33.97461	-118.37115	Plan check for power and energy. Project site is a new 3-story, 18-unit apartment building with 1 level of subterranean parking. Work includes a new 800 amp service. Area is a methan zone/methane buffer zone. Total lighting area = 16,635 sq. ft.Note: Building application has been created under 15010-30000-00317	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48053	12041-20000-22851	11744 N LUANDA ST	91342	7	213B169    32	2531031040	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.28451	-118.38725	New 8.57kw enphase system on rooftop of a single family residence including service upgrade to 225 ampere bussing with 200 ampere main to comply with the 120% rule of 690.64(B)(2).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48054	19041-10000-14056	1129 W 37TH ST	90007	8	120B197  1111	5040030019	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.02108	-118.29263	NEW FIRE ALARM SYSTEM WITH CENTRAL STATION MONITORING FOR 5UNITS CONDOS BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48055	19041-10000-53001	14124 W FOOTHILL BLVD STE 100	91342	7	225B153   159	2504011157	C2-1XL-CPIO	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.31595	-118.44168	REPLACE FLOURESCENT TROFFERS WITH NEW LED RETROFIT KITS (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48056	18041-10000-05882	7826 S BROADWAY	90003	9	099B201   549	6031020004	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	33.96808	-118.27809	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 13775 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48057	10041-20003-15146	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	as built drawings required by inspection	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48058	15041-10001-24183	2011 S WESTWOOD BLVD	90025	5	129B153  1025	4323003015	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.0463	-118.43402	SERVICEWAS CHANGED TO 120/240V 3PH 4W 600A FROM 1120/208V 3PH 4W 400A AC UNITS WERE SUPPLIED FROM EEDERS AND EACH PANEBOARD HAS A FEEDERTOTAL LOAD IS 457A)))))))). CHANGE OF USE TO RESTAURANT. ADDED LOAD IS LESS THAN 400APLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48059	15041-20000-39991	8724 N OAK PARK AVE	91325	12	195B133   399	2690010010	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	01/09/2016 12:00:00 AM	ADDRESS	34.22921	-118.50556	PV1. Install roof mounted PV system sized 11.4 kW. Interconnectd with main service panel.(41) SunEdison 325W Modules(41) SolarEdge P320 Power Optimizers(1) Solar Edge SE11400A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48060	17041-10000-05517	14668 W LIMEDALE ST	91402	6	201B149   712	2650024008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.24442	-118.4528	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.06KWdc / 3.6KWac.(14)MODULES-SOLARWORLD SW 290(1)INVERTER-SOLIS 3.6K-2G-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48061	17041-20001-20141	6033 W CENTURY BLVD 710	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	33.94572	-118.38954	Supplemental permit and plan check for replacement of luminaires and new controls throughout office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48062	14041-20000-27834	7022 N WHITAKER AVE	91406	6	183B137   209	2225012007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Expired	11/01/2016 12:00:00 AM	ADDRESS	34.19819	-118.49768	PV1.  Install 5.355 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48063	19041-20000-20450	5657 N LUBAO AVE	91367	3	174B113   256	2153002015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.17384	-118.5675	Plan check for PV roof mounted system, system size: 11.16kW DC, 14.47kW AC CEC with 36 PV Modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48064	13041-10001-27130	6247 S FAIRFAX AVE	90056	11	105B177   393	4002005004	R2-1XL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	33.98272	-118.36144	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 4.5 kW. TRANSFORMERLESS INVERTER. UNGROUNDED SYSTEM.(18) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-4.2-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48065	16041-10002-29528	821 S MATEO ST	90021	14	123A217    49	5166017013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.03285	-118.23244	10/04/16Changes to an approved set of plans. All changes are clouded. Changes include relocating AC disconnect, inverters, and solar load center on the roof layout. Note: Permit is paid under PCIS#16041-10000-29528((((((New PV solar system on existing commercial building.  38 new PV modules, two new 6 KW inverters, new subpanel feeding existing loads, and new load center to combine AC inverter outputs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48066	14041-20001-02177	9546 N MELVIN AVE	91324	12	201B117   617	2761007028	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	ADDRESS	34.24405	-118.56	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 16KW AC USING 2 INVERTERS WITH ISOLATION TRANSFORMER. 3 STRINGS/ INVERTER $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48067	14041-20001-01326	6522 N BELMAR AVE	91335	3	180B117   661	2131027003	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.18888	-118.55803	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN 2 STRINGS (((change in single line. removal of bonding jumper bonding 2 grounding electrodes together. each electrode must be 6ft away from the other.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48068	10041-20000-01804	13359 W VENTURA BLVD	91423	5	165B157   764	2360011023	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	02/09/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.14705	-118.42436	Tenant improvement -remodel of restaurant. Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48069	16041-10002-12519	3812 W OAKWOOD AVE	90004	13	138B197    84	5501001023	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM			PC Approved	07/21/2016 12:00:00 AM	ADDRESS	34.07761	-118.28979	NOTE: PERMIT FOR SOLAR ARRAYS ON STRUCTURES 3812 OAKWOOD, 3812-1/2 OAKWOOD, AND 3814-1/4 OAKWOOD ARE UNDER METER ADDRESS 3812 OAKWOOD AVE. ALL CHANGES ARE CLOUDED UNDER DELTA 4.Note: Permit was paid under PCIS#16041-10000-12519 (((PV1, INSTALL 9.75 KW AC, 10.725 KW DC  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(39) MODULES:SOLARWORLD SW 275 MONO BLK(39) MICROINVERTER: ENPHASE ENERGY M250-60-2LL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48070	12041-10002-04614	9301 N TAMPA AVE #216	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM			PC Approved	10/18/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	CHANGES TO APPROVED SET OF PLANS-increased size of phase conductors to meet voltage drop concerns ;also increased EGC per code(((((((((Change of use from commercial to a new restaurant.  New switchboard,  panels,  loads, circuits, receptacles, lighting.  Variance will be submitted to seperate the fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48071	17041-10000-12061	850 E 111TH PL	90059	8	088-5A209 241	6071022006	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Closed	11/13/2020 12:00:00 AM	ADDRESS	33.93557	-118.25914	PC FOR POWER. INSTALLING A NEW COMPERESSED NATURAL GAS(CNG) VEHICLE FUELING SYSTEM. INCLUDES 3 COMPRESSORS, AND ONE FUTURE GAS DRYER. HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48072	12041-20000-21785	707 W WILSHIRE BLVD Floors 57-60	90017	9	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.04893	-118.2572	Plan check for power and energy. Morrison and Foerster. 66335sqft. Floors 57-60.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48073	16041-20000-05829	5812 W VIRGINIA AVE	90038	13	144B189   519	5534017012	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			02/18/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.09167	-118.31619	Plan check for New appartment building 12 units. Service size: 800A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48074	14041-10000-02691	1323 S VICTORIA AVE	90019	10	129B185  1117	5082015010	R2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.04714	-118.32877	PV1, Install 4.24 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U.(16) Modules: SUNIVA OPT265-60-4-1B0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48075	17041-20000-37921	15435 W MILBANK ST	91403	5	168B145   521	2261038051	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	PIN	34.15698768	-118.47060755	Plan check for solar pv system, roof-mounted array on SFD.7,360kW ungrounded system.(32) EnPhase IQ6 microinverters.(32) 295W pv modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48076	11041-20000-20301	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Info Complete	09/23/2011 12:00:00 AM	ADDRESS	33.78808	-118.29535	Installing antenas on columns of parking structure.  Plan check was for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48077	13041-10000-21949	6332 S BRYNHURST AVE	90043	8	105B185  1015	4006008018	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			08/14/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	33.98193	-118.33365	FA FOR BRYNHURST APARTMENTS. 3 STORIES 12 UNITS. 1 panel. 1 anunciator. 53 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48078	17041-10000-35364	10250 W SANTA MONICA BLVD # 2660	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full PC for power and energy. First tenant - in commercial space at Century city mall- Hello Darling Salon. Scope includes new panels, circuits, and lights. Total affected area is 992 Sq. Ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48079	08041-10003-22171	448 S HILL ST 6th floor	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.04896	-118.25139	This is an AS BUILT aplication.  Work was done under a permit under 08041-10000-22171 that has since expired.  Applicant has included the original approved set of plans. <<<<<New work on the 6th floor.  A variance to separate the electrical and fire life safety system was submitted.  Electrical plan check is for Power, emergency lighting and T24 lighting.>>>>>>> changes to previously approved set	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48080	16041-10002-01112	6901 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM			PC Approved	03/02/2017 12:00:00 AM	ADDRESS	33.93195	-118.41136	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGE CIRCUIT DESIGNATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48081	16041-30000-18965	444 S FLOWER ST Suite 4300	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is Suite 4300 of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,590 sq. ft.Note: Building application has been created under 16016-10000-08862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48082	16041-10000-44326	555 W 5TH ST 2900	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	OFFICE TI IN SUITE 2900. TITLE T24 USE SHOWN AS SHOWROOM. THIS AREA MUST BE USED FOR THE PURPOSES OF PRODUCT DISPLAY/ RETAIL PURPOSES ONLY IN ACCORDANCE WITH CEC. INSPECTOR TO FIELD VERIFY USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48083	17041-10002-16935	1808 N VERMONT AVE	90027	4	150B197  1119	5590020001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM			PC Approved	07/31/2017 12:00:00 AM	ADDRESS	34.10392	-118.29162	Revision to approved set to reflect changes on the field. Channges includes additional lights some receptacles and equipment disconnect.Revision to T-24 documents to reflecet changes. Plan check only!!!****************************************************************************** T-24, PC FOR ENERGY ONLY. TI FOR EXISTING STORE. SCOPE INCLUDES NEW LIGHTS, NEW RECEPTACLES, AND ONE NEW 200A PANEL. TOTAL AFFECTED AREA IS 847 SQ. FT.  COMPLY WITH DEPT. ORDER DATED 4/18/17. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE.NOTE: MOST OF THE FEES FOR PERMIT WERE PULLED UNDER PCIS#17041-70000-16935	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48084	13041-20000-29653	634 W 23RD ST	90007	1	123A203   152	5124028004	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.03118	-118.27534	PC FOR T24 ENERGY ONLY. NEW LIGHTING FOR CLASSROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48085	12041-10000-01808	5200 N LANKERSHIM BLVD	91601	4	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.16511	-118.37448	low rise per customer , title 24 and emergency. lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48086	17041-10001-45719	1128 N HYATT AVE	90744	15	033B209   538	7423027058	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	33.78589	-118.25403	Supplementel PV expedite.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48087	10041-10000-23182	1311 W 37TH ST	90007	8	120B197  1150	5040009028	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	34.02109	-118.29795	T.I. in an existing church. EPC is for T24 and emergency lights. (Permit was pulled # 10041-4000-19082)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48088	10041-20000-14415	20122 W VANOWEN ST	91306	3	180B113    25	2134014024	(T)(Q)C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	34.19364	-118.57195	MODIFY EX CELL SITE. NEW 800 AMP SERVICE AND PANELS FOR FUTURE USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48089	12041-10000-16921	1801 S FIGUEROA ST	90015		124-5A205 281	5126002008	CM-2-O		South Los Angeles	Downtown Los Angeles			Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM			Reviewed by Supervisor	12/27/2012 12:00:00 AM	ADDRESS	34.03524	-118.27179	"PLAN CHECK POWER AND ENERGY FOR NEW 7-STORY BUILDING STRUCTURE W/ MEZZ AT 1ST LEVEL. GROUND LEVEL AUTO REPAIR SERVICE STATION. BUILDING IN METHANE ZONE. ""PORTION A"" PROJECT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48090	16041-20000-30066	23223 W LIAHONA PL	91364	3	168B093   252	2074033034	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.15459	-118.63155	PV1INSTALL ROOF MOUNTED PV SYSTEM (ACM) SIZED 10.2KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48091	14041-10004-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	12/23/2016 Changes to an approved set of plans. Changes include additonal load and panel boards, revised load calculaiton. Changes has bee clouded as delta 22, 23, and 24This project is phase 3 of Westfield Century City which includes all underground areas and parking garage areas plus main service, switchgear, conduits, and distribution panels for tenants.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48092	19041-10001-42079	2125 N DALY ST	90031	1	136-5A221  38	5204008021	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.07009	-118.21566	"DELTA ""1"" Changes to approved plans for relocating the PV Inverter, MSP & AC Disconnect. Plan Check Only.<<<PLAN CHECK FOR NEW PV SYSTEM, SYSTEM SIZE: 4.03 KW DC; 3.8 KW AC; 13 MODULES (CANADIAN SOLAR 310 WATT MODULES), 13 OPTIMIZERS (SE P320); 1  INVERTER (SOLAR EDGE 3.8 KW)>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48093	15041-10000-06518	6344 N TOPANGA CANYON BLVD BLDG A	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	09/06/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	NEW FIRE ALARM SYSTEM IN BUILDING A ON WESTFIELD PLAZA. 134 DEVICES AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48094	14041-10001-22160	5647 W TRYON ROAD	90068	4	151-5A193 263	5587021026	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			Reviewed by Supervisor	09/09/2014 12:00:00 AM	ADDRESS	34.10763	-118.31109	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 7.14 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(28) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48095	17041-20000-21338	3550 W WILSHIRE BLVD	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.06157	-118.30226	$0 permit fee per State Senate Bill SB 1222.PV2. ROOFMOUNTED SOLAR SYSTEM.  PARKING CANOPY ON ROOF OF A PARKING STRUCTURE. 914.55 KW DC/809.08 KW AC CEC.(2814) PS325M PV MODULES(12) PVI 60TL SOLECTRIABUILDING PERMIT # 17014-20000-03027	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48096	11041-20000-08682	9300 N MASON AVE	91311	12	198B109    98	2748022060	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM	04/29/2011 12:00:00 AM		Permit Expired	05/22/2013 12:00:00 AM	ADDRESS	34.23931	-118.57958	T.I. to an existing warehouse.  Install general lighting in Area 3 and Area 5 as shown on plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48097	19041-10000-03138	4959 W ROMAINE ST	90029	13	144B197  1098	5538003011	R3-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	06/29/2022 12:00:00 AM	ADDRESS	34.08863	-118.2994	PC for pwr upgrade from 300A to 600A switchboard. Upgrade of 20 tenant panels, (1) house panel, and adding a total of 102 ckts. scope of work 12000 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48098	16041-20001-16874	10626 S GORMAN AVE	90002	15	090A217   506	6066014065	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	33.93899	-118.23058	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 8.7kW with 35 modules and 35 microinverters Enphase.}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48099	18041-20001-05552	20821 W BERMUDA ST	91311	12	207B109   208	2706027028	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.26556	-118.58744	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.12 kWac and consists of (34) AC PV modules and (1) load center. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48100	15041-10000-29082	6801 W HOLLYWOOD BLVD #B157	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	TI for an existing commercial build. adding new lights, control ,new panel, newly connected load < 400 A.PC for Energy only. Total area: 1012 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48101	18041-30000-15534	5229 N WILLOW CREST AVE 1-24	91601	2	171B177   510	2416028047	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Issued	04/26/2018 12:00:00 AM	ADDRESS	34.16576	-118.3624	Plan check for a fire alarm system for an apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (77) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48102	18041-10000-42462	5014 E HUNTINGTON DR SOUTH	90032	14	144A235   263	5218009012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.08803	-118.17314	FULL ELECTRICAL PLAN CHECK FOR POWER AND ENERGY FOR COIN LAUNDRY 9 SUBPANELS AND 1 MAIN 600 AMP SWITCHBOARD WITH 3766 SQFT AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48103	17041-20000-18241	601 W 5TH ST ste 720	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	ti to an existing commercial high rise building.  adding new lighting new controls to existing panels.  plan check for energy and em lightig only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48104	15041-10000-12516	3760 S MOTOR AVE	90034	5	120B165  1357	4314004036	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.0213	-118.40438	TI TO AN EXISTING THREE STORY COMMERCIAL BUILDING, NO CHANGE IN USE.  NEWLY CONNECTED LOAD >400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL AQUARE FOOTAGE 15000. SCOPE OF WORK TO BE PERFORMED IN THE THREE FLOORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48105	16041-10000-10058	1635 N CAHUENGA BLVD 6TH FLR	90028	13	148-5A187 221	5546007028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.10071	-118.32971	T-24 FOR A TI IN AN (E) OFFICE BUILDING ON THE 6TH FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 7500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48106	15041-10000-19233	11333 N SEPULVEDA BLVD 2ND FLR	91345	7	213B145   166	2664001027	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.27646	-118.46863	TI TO AN EXISTING MEDICAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK IN THE 2ND FLOOR.  TOTAL SQUARE FOOTAGE 912.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48107	12041-20000-26466	20340 W SUPERIOR ST	91311	12	201B113   624	2748015039	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.24648	-118.5769	PV-1. Plan check for PV system. SIngle family dwelling. 20 microinverters =  4.3kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48108	12041-10000-28194	10457 W CAMARILLO ST	91601	4	168B177   418	2420005020	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	PIN	34.15830162	-118.35917206	ROOF MOUNTED PV1 5.39KW SOLAR INSTALLATION. 22 MICROINVERTERS USING STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48109	15041-10000-18080	11811 S TEALE ST	90230	11	105B165   298	4220006075	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Issued	01/21/2016 12:00:00 AM	ADDRESS	33.98545	-118.40128	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48110	18041-20001-35025	5232 E BALTIMORE ST	90042	1	154-5A225 270	5478017007	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM			PC Approved	09/22/2018 12:00:00 AM	ADDRESS	34.11776	-118.20222	Expedite per applicant requestPlan check for PV plus battery storage system, PV system size: 7.6kW with 12 modules and with LG Chem Resu 9.8kWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48111	16041-20000-41176	10705 N TURNBOW DR	91040	7	207B189   698	2547009002	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.26337	-118.32433	Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP. Derating main breaker to 175A. 3.8kW ungrounded system. (13) 260W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48112	15041-10000-19160	700 W 7TH ST G340	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR ENERGY. T.I. POST OFFICE  RETAIL STORE IN THE MALL. TOTAL AREA 1938 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48113	16041-20001-20065	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	"(2/2/2017)changes to an approved set of plans.  changes noted delta 3.  changes include new distribution board ""TDA"" and reconnect existing feeders to units 100, 101, and 102.PLANCHECK FOR POWER AND ENERGY ON PLAZA LEVEL. TENANT IMPROVEMENT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48114	12041-10000-20326	7550 W JALMIA WAY	90046	4	153B177   102	5571001021	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2012 12:00:00 AM			Reviewed by Supervisor	09/13/2012 12:00:00 AM	ADDRESS	34.11851	-118.35974	4.23 kw roof mounted pv system for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48115	16041-10000-43201	10250 W SANTA MONICA BLVD UNIT 1815	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER AND ENERGY FOR FIRST TIME TENANT IN SPACE 1815 - SWAROVSKI. NEW TRANSFORMER AND FEW LOADS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48116	14041-10000-04185	3850 W WILSHIRE BLVD SUITE 107	90010	10	132B193    82	5093005001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.06153	-118.31086	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM RESTARUANT TO COFFEE SHOP.; NEW KITCHEN. 1450 SQFT, EMERGENCY LIGHTING. all work to be indoorsBUILDING P# 14016-10000-01558 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48117	13041-10000-26331	22674 W CRESPI ST	91364	3	171B097   777	2075013042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.16342	-118.62017	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON STANDARD PLAN , XFORMERLESS SYSTEM; SYSTEM SIZE IS 5.145KW DC WITH (21) MODULES: TRINA #TSM-245PA05.18(1) POWER-ONE #AURORA PVI-3600	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48118	17041-20000-16211	1580 E JESSE ST	90021	14	124-5A217 119	5164018010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.03625	-118.22968	ti to an existing commercial building two story, coverting from warehouse to office.  existing service new tenant panels and circuits.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48119	19041-10000-33248	800 W 6TH ST 430	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	Energy plan check for an office TI located in the 4th floor of a high rise building. Scope includes new lighitng and equipment with a total lighting area of 2,923 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48120	15041-20001-39956	4849 N VAN NUYS BLVD #200	91403	4	169-5A151  98	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.15918	-118.44892	12/17/15Changes to approved set. Changes made under delta 2. Changes include new lighting fixtures, receptacles, and EGC conductor size increase from feeder. ((((Non structural tenant improvment to the (e) medical office, scope of work includes exam rooms. Total area 1,029sq.ft. Adding new X-Ray ckt breaker 100A (10kW).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48121	18041-20001-46238	8310 N PONCE AVE	91304	12	192B097   416	2004001030	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	34.21997	-118.62123	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWdc/10.6 kWac and consists of (2) inverters, (36) modules, (2) load centers, (1) transformer, and (1) back-up battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48122	13041-10000-23711	13480 W MAXELLA AVE	90292	11	105B153   738	4212004031	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	33.98522	-118.44179	PLAN CHECK FOR TITLE 24 ONLY. 8800 SQFT, EMERGENCY LIGHTING. 5 STORIES. WORK ON GROUND LEVEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48123	16041-20001-21199	10351 W DIAMOND ST LOT 6	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48124	18041-10000-20015	1355 N VINE ST BLG B	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM	ADDRESS	34.0956	-118.32685	NEW FIRE ALARM SYSTEM IN A NEW COMMERCIAL BUILDING.BUILDING PERMIT #15010-10000-04706	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48125	14041-10000-27907	6851 N LAUREL CANYON BLVD	91605	2	183B165   490	2321026040	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Public Safety Only			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.19528	-118.39677	NEW FIRE WARNING SYSTEM FOR APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48126	14041-10000-27405	412 S BUNDY DR	90049	11	132B141   788	4404022017	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.05535	-118.47547	PV1 Standard Plan with 8.8KW roof-mounted system including: (1) 3.8 and 5.0KW inverters, (39) Kyocera KD255 modules and (39) Solaredge P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48127	15041-20000-06438	5037 N FULTON AVE	91423	4	171B157   915	2359010005	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Expired	03/29/2017 12:00:00 AM	ADDRESS	34.16223	-118.42267	PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service pannel. (49) Kyocera 255 Modules(2) 5000W Inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48128	19041-20001-19948	9121 W LA TUNA CANYON ROAD	91352	7	198B185    42	2545024022	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.23661	-118.3316	Expedited plan check fee.PV1.  Install 21.00 kW DC / 18.85 kW AC roof mounted grid tied PV system.  (56) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48129	16041-10000-28595	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	Full Plan check. First time tenant TI for a new starbucks in a shopping center (The Bloc). Adding new electrical equipment (2 panelboards) to existing serice. New lighting and power. Total sqft = 1896	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48130	17041-20000-06452	21700 W OXNARD ST ste 1500	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Info Complete	02/28/2017 12:00:00 AM	ADDRESS	34.17901	-118.60179	ti to an existing commercial building (highrise) adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 1150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48131	14041-20000-00855	6417 W SELMA AVE	90028	13	148-5A187 302	5546007022	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Closed	01/04/2017 12:00:00 AM	ADDRESS	34.09988	-118.33008	New 10 story Hotel - Dream Hollywood.  2 services due to utility provisions. pc for power and energy. plan check time extension has been filed. 8/10/15.per building submittal, plan check in accordance to 2008 NECFire alarm variance has been filed. 9/4/15	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48132	15041-20000-27373	10146 N SHOSHONE AVE	91325	12	204B129   288	2734015002	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Expired	09/15/2017 12:00:00 AM	ADDRESS	34.25553	-118.51746	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48133	11041-20000-19079	19522 W VENTURA BLVD	91356	3	174B117   324	2164016027	C2-1VLD, P-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	12/01/2011 12:00:00 AM	ADDRESS	34.17252	-118.55869	ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48134	11041-10001-27270	470 E SWINFORD ST	90731	15	021B201   196	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	33.74945	-118.2748	"Cruise terminal bldg. for ""Catalina Express""(Change of Use from banquet hall to banquet hall/cruise terminal building with offices, cafe, and cocktail bar. Work includes interior tenant improvement, storefront remodel and door/window replacement and re-stripe the parking lot for H/C and green auto parking spaces.) 6-16-12 addition of panel c with refrigeration load and few ckts."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48135	10041-20000-20950	11075 W SANTA MONICA BLVD #200	90025	5	129B153   757	4324033022	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM			PC Info Complete	10/21/2010 12:00:00 AM	ADDRESS	34.04799	-118.44397	T.I. to low rise building in 2nd floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48136	14041-20000-24343	6534 N LUBAO AVE	91367	3	180B113   554	2134040014	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.18937	-118.56794	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48137	12041-20001-20565	11090 W SANTA MONICA BLVD	90025	5	129B153   858	4323020037	C2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.04751	-118.4439	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48138	13041-20000-04678	970 N MONUMENT ST #102	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM			PC Approved	02/22/2013 12:00:00 AM	ADDRESS	34.04646	-118.52393	Plan Check only for Energy to an existing retail space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48139	10041-10000-21629	2000 S AVENUE OF THE STARS Suite 1000	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	T24 lighting plan check for suite 1000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48140	17041-20001-29751	7601 N WHITE OAK AVE	91335	12	186B129   218	2120002031	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM			PC Approved	11/22/2017 12:00:00 AM	ADDRESS	34.20879	-118.51879	[[[11/22/17 CHANGES TO APPROVED T24 ENERGY. PLANCHECK ONLY. CHANGES ARE CLOUDED. DELTA 1 CHANGES]]]]Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 670 sq. ft.Note: Building permit has been issued under 17016-30000-11822	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48141	15041-20000-14100	6703 N VALJEAN AVE	91406	6	180B137   117	2233031041	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Expired	07/17/2017 12:00:00 AM	ADDRESS	34.19205	-118.4861	Service upgrade for existing manufacturing building.  New service is 800 A 3 phase 208 V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48142	11041-10000-01573	18700 W VENTURA BLVD #120-Starbucks	91356	3	174B121   811	2161026002		South Valley				1394.00	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.17045	-118.54081	First time tenant for a Starbucks Coffee in suite #120. EPC is for power & energy. (Core & Shell was approved under separate application 07041-10000-15722.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48143	13041-10000-03977	707 W WILSHIRE BLVD 4360	90017	9	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI OF EXISTING OFFICE SPACE. ALTERATION FOR NEW OFFICE SPACE. TOTAL SQ FT. 1812. PC FOR T24 ONLY. PERMIT TO BE ISSUED BY PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48144	12041-10000-23229	626 N NORTH MAIN ST	90012	14	132A215    40	5408011907	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Expired	10/22/2014 12:00:00 AM	ADDRESS	34.05757	-118.23817	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48145	15041-20000-14392	5430 S CRENSHAW BLVD UNIT A	90043	8	108B185   458	5006008008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.9922	-118.33046	PC FOR PV SYSTEM. 3KW AC USING SINGLE TRANSFORMERLESS INVERTER. THIS SYSTEM CONNECTS TO TENANT AT 5430A CRENSHAW. THIS IS PROJECT 5/5. ALL SYSTEMS CONNECT TO SINGLE 400A SINGLE PHASE SERVICE. ZONING AND CRA HAVE BEEN CLEARED UNDER PROJECT 1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48146	17041-10000-24584	10010 S JUNIPER ST 101-301	90002	15	091-5A217 111	6046019929	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/11/2020 12:00:00 AM	ADDRESS	33.94626	-118.23331	NEW 3 STORY, 7 UNIT APARTMENT BUILDING. 400 A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48147	12041-20000-24621	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM			PC Approved	10/17/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	T.I. to reception area in the basement level.  Install general/emergency lighting.  Plan check for energy only.  Per applicant, only the area in the reception area is included in the scope of work.  NO lighting fixtures in the corridor are to be relocated or changed..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48148	16041-20000-03741	5161 N LANKERSHIM BLVD 4th floor	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.16452	-118.37469	Plan check for power and energy. Project scope is an existing commercial building. Project scope is a tenant improvement to the 4th floor. Total lighting area = 34,010 sq. ft.Note: Building application has been created under 16016-10000-02082	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48149	14041-10000-07049	8144 N WILLIS AVE	91402	6	192B149   574	2210014018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.21917	-118.45516	PV1, INSTALL  A 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(14)MODULES: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48150	12041-20000-05120	865 S FIGUEROA ST # 3320	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.04653	-118.26275	T-24 lighting plan check for remodeled tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48151	16041-20001-13266	10452 N RAINTREE LANE	91326	12	207B121   739	2728031059	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.26107	-118.54283	RSES expedited plan check fee. PV1.  Install 18.285 kW DC roof-mounted PV system.  (53) 345 W PV AC modules - SPR-X21-345-C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48152	18041-10000-32516	2416 E HUNTER ST	90021	14	121-5A217 194	5168030008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.02751	-118.2291	PLAN CHECK FOR POWER AND ENERGY FOR TI on EXISTING WAREHOUSE - GARMENT MANUFACTURING - TOTAL NEW CONNECTED LOAD >400A , NEW PANELBOARDS ON EXISTING SERVICE. TOTAL NEW AFFECTED AREA = 23,399 SF(B# 18016-10000-12461)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48153	10041-20000-03319	707 S WESTMORELAND AVE	90005	10	132B197   217	5077017001	C2-1	Central	Wilshire	MacArthur Park		2122.03, 2122.04	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.05952	-118.28922	service upgrade to 800 AThis building is multitenant building with addresses 707-717 Westmoreland & 3000-3010 7th St.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48154	12041-10000-24856	14549 W WILLOWGREEN LANE	91342	7	228B149   732	2502023***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.31991	-118.45144	NEW 4.32 KW ROOF MOUNTED PV FOR A SINGLE FAMILY. (PV1)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48155	19041-20000-30136	925 W 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	PIN	34.02383917	-118.28572873	Power for simulation benches used in educational facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48156	16041-20000-31347	3160 W RIVERSIDE DR	90027	4	153A205    73	5434017005	[T][Q]R4-1-RIO	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	Apartment			09/02/2016 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	04/12/2021 12:00:00 AM	ADDRESS	34.11377	-118.26929	Plan check for power and energy. Project site is a new 5-story, 65-unit apartment building. Work includes a 2000-amp service, associated distribution boards, and a total lighting area of 57,916 sq. ft.Note: Building application has been generated under 16010-10000-02827	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48157	14041-10001-19705	17200 W VENTURA BLVD #224 & 225	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM			PC Approved	11/26/2014 12:00:00 AM	ADDRESS	34.16035	-118.50769	Change to approved set by adding a day-light control diagram on the original plan; change is under delta-1 only.(((Plan check for energy only. 2013 T24. BLDG#14016 10 14295 : TI TO (E) RESTAURANT. NO CHANGE OF USE. DEMO ALL INTERIOR PARTITIONS AND REPLACE WITH NEW PARTITIONS AND COUNTER AND KITCHEN.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48158	17041-10002-24720	1350 N IVAR AVE	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	11/20/2020 12:00:00 AM				Changes to an approved set, all changes are under bulletin 2.1,3,3.1,4.1,7,8,8.1. Scope of work includes upgrading various panels frm 225A to 400A, installing new equiment. A narrative letter was provided.((PC FOR SHELL  AND CORE FOR MIXED-USE COMMERCIAL DEVELOPMENT WITH 3 LEVELS BELOW GRADE PARKING FOR POWER AND ENERGY.SCOPE INCLUDES 3 SERVICES :TWO  5000A 277/480 AND ONE 4000A 277/480TOTAL AFFECTED AREA (INDOOR +OUTDOOR)  680682+82107=762789 SQ.FT.B# 15010-10000-04706))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48159	19041-10001-04385	4507 N ELLENITA AVE	91356	3	165B117    58	2178031008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.15189	-118.56324	Plan check for a roof-mounted solar PV 10.37KW DC/ 8.16KW AC system. Scope includes (34) Enphase IQ7 micorinverter and modules interconneting through the main service panel.portion of the permit fee is paid under 19041-90000-04385.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48160	12041-10002-09171	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.0754	-118.38272	(((6/25/14)))) CHANGES TO APPROVED SET OF PLANS. DELTA 10 CHANGES ONLY. CHANGING TO T24 AND ADDING RECEPETACLES. ADJUSTMENTS TO THE PANEL SCHEDULE AND LOAD CALS. PLAN CHECK ONLY.CHANGES TO APPROVED SET OF PLAN. PERMIT HAS NOT BEEN PULLED YET. CHANGES HAVE BEEN CLOUDED AND A SHEET OF CHANGES HAS BEEN INCLUDED. LOCATION OF NEW EQUIPMENT HAVE BEEN MOVED. SEDARS SINAI . AS-BUILT SET OF PLANSNew switch boards, 625 kva generator, , mechanical equipment, circuits for first floor of  an existing 2-story, Cedar's Sinai Laboratory building.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48161	19041-10000-33146	1772 S OGDEN DR	90019	10	126B173   366	5069004022	R1R3-RG	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	34.0433	-118.36677	PV1 roof mounted solar system using central inverter and Tesla battery back up system. Total (25) modules, (25) Optimizers, (1) 7.6 Inverter and (2)13.5 kwh Tesla Powerwall 2. Total system size is 7.6kwac/ 7.5kwdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48162	13041-20001-15458	4824 N VINELAND AVE	91601	2	168B173   369	2421014001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.15833	-118.37007	((CHANGES MADE TO APPROVED SET OF PLANS. ADDED SOME OUTDOOR LIGHTING AND REVISED SOME INDOOR LIGHTING))RENOVATION OF INTERIOR OF EXISTING RESTARAUNT, PC FOR T24 ENERGY ONLY.  NEW CONNECTED LOAD LESS THEN 400A.   Occupancy load is less that 99 per building permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48163	16041-20000-17597	20545 W PLUMMER ST	91311	12	198B109    19	2748003085	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.24291	-118.58123	Plan chek for Title 24 only. T.I to existing idustrial building/wearhouse. New offices; restrooms. New lighting and receptacle. Total area: 10,235 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48164	17041-10001-39185	312 S ALAMEDA ST	90013	14	127-5A215  66	5163010009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.04494	-118.23784	PC FOR CHANGES TO APPROVED  SET UNDER DELTA 8.SCOPE INCLUDES CAHNGES TO LIGHTS AND REVISIONS TO T-24. THIS IS PLAN CHECK ONLY. PERMIT PAID UNDER MASTER.  PC for power and energy for first time restuarant tenant. Installing three new panels, new equipment, circuits, lights and receptacles. Total area is 3520sqft. Total area is	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48165	19041-20001-46999	20422 W VIA BOTTICELLI	91326	12	219B109   225	2701059007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.29849	-118.57912	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE IN PV MODULE MODEL, SYSTEM DC SIZE CHANGED FROM 10.385 KW TO 10.85 KW, AC SYSTEM SIZE UNCHANGED, CHANGE MADE TO COVER PAGE, SINGLE LINE, AND ROOF LAYOUT PAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48166	16041-20001-09556	4318 S KANSAS AVE	90037	9	114B197  1199	5020025014	R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Apartment			06/27/2017 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	03/04/2022 12:00:00 AM	ADDRESS	34.00489	-118.29359	[[[ 6/27/17 CHANGES TO APPROVED SET. CHANGES ARE CLOUDED DELTA 1. ADDITION OF LOADS AND PANELBOARD HP3]]]]Plan check for power and energy. Project site is a new 3-story, 22-unit apartment building. Total lighting area = 21,165 sq. ft.Note: Building application has been generated under 16010-20000-00549	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48167	16041-20000-14814	9913 N TUNNEY AVE	91324	12	201B117    71	2726013017	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.25044	-118.55807	"""$0 permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48168	16041-10000-06317	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	T-24, TI TO AN OFFICE SPACE IN THE 22ND AND 23RD FLOOR OF A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 22,783.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48169	15041-10000-24061	1500 W PACIFIC COAST HWY Bldg F1	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 2-story, 2 unit apartment with garage, . 11 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48170	18041-10002-46963	3246 S BARBYDELL DR	90064	5	123B165   645	4316025009	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.0332	-118.40325	PC ADDITION OF 1 ESS TO AN APPROVED SET OF 10KW ROOFTOP PV SYSTEM AND 28KW ENERGY STORAGE SYSTEM. ESS IS 5KW. AND ADDITION OF  1 NEW LOAD CENTER. CHANGE IS MARKED DELTA-1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48171	15041-10000-23491	11985 W BLUFF CREEK DR CAFE	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.98221	-118.40251	FULL PC, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER IN THE CAFETERIA. PANELS FOR CAFETERIA ARE COVERED UNDER APP#: 15041-10000-23464,WORKSPACE.    TOTAL SQ. FT. 9971. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48172	17041-20000-32161	12112 W LAUREL TERRACE DR	91604	2	162B165   938	2376015005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.13797	-118.39635	Plan check for solar pv system, roof-mounted on SFD. Derating main to 175A.11.4kW ungrounded system. (47) 325W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48173	18041-10000-00801	854 N VERMONT AVE	90029	13	144B197  1388	5539010021	[Q]C2-1	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.08686	-118.29152	PC for T24 only for change of use from retail to restuarant. Installing new lights, receptacles and relocating panelboard.Total area is 1263sqft.B16016-10000-28991	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48174	13041-10000-16308	201 WORLD WAY	90045	11	090B165    76	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Expired	08/01/2017 12:00:00 AM	ADDRESS	33.94469	-118.40336	PLAN CHECK FOR TITLE 24 PART 6 ENERGY. INDOOR AND OUTDOOR/FACADE LIGHITNG AT LAX. SCOPE OF WORK < 400A. ONE TOWER FOUR FLOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48175	19041-10000-10873	4557 W ROSEWOOD AVE	90004	13	141B193  1357	5521019005	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.07911	-118.3037	PC for FA , Scope includes 1 FACP. 1 FCPS and 51 Devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48176	19041-20000-23105	20343 W LANDER DR	91364	3	168B113   399	2174017011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.15513	-118.57627	Plan check for PV roof mounted system, PV system size: 11.295 KW DC, 9.972KW AC CEC. with 37 PV Modules and 37 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48177	16041-10000-36471	6011 N BELLAIRE AVE	91606	2	177B161   909	2332028007	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.17975	-118.40961	PV1 roof mounted solar system installation to a single family home. Installing 3.0 KW inverter(Model #: ABB-=PV1-3.0-TL-OUTD), and 10 modules(Model # LG310N1C-G4).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48178	18041-10000-44474	624 S PACIFIC AVE	90731	15	015B197   463	7455005026	[Q]C2-1XL-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	33.73824	-118.28773	PC only. TI FOR A CHANGE OF USE RETAIL TO FURNITURE RETAIL. SCOPE INCLUDES NEW 400A PANEL, TWO 100A PANELS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA 9576 SQ.FT. T-24 ONLYPermit fees are paid under 19041-10000-11509 &19041-10001-11509	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48179	12041-10000-16644	13370 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15935	-118.42435	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #7	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48180	12041-20000-08673	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	T.I. to the main lobby.  Install general/emergency light.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48181	12041-20000-25881	1901 S AVENUE OF THE STARS # 1700	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/29/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.05949	-118.41705	Instll new lighting and power outlets for a remodel of vairious small offices of suite 1700.  Plan check for T-24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48182	18041-10000-42407	5343 W IMPERIAL HWY 700	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	33.93128	-118.37337	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48183	16041-20000-12672	2104 W COLORADO BLVD Suite B	90041	14	162A223   121	5686003018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM			PC Approved	04/12/2016 12:00:00 AM	ADDRESS	34.13897	-118.21223	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,731 sq. ft.Note: Building application has been generated under 16016-20000-07953	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48184	17041-20000-46278	10960 W BELLAGIO ROAD	90077	5	141B149   247	4366001006	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.07962	-118.4569	Plan check for solar pv system w/roof-mounted array on SFD.6.72kW ungrounded system.(24) EnPhase IQ6PLUS-72 microinverters.(24) 360W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48185	18041-10000-08657	11100 W SANTA MONICA BLVD #200	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLAN CHEK FOR TITLE 24 ONLY FOR - INTERIOR OFFICE REMODEL. DEMO NON-STRUCTURAL WALLS AND CONSTRUCTION. TOTAL AFFECTED AREA = 1577 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48186	15041-20005-02895	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	CHANGES TO APPROVED SET OF PLANS. CHANGES TO CIRCUIT DESIGNATION OF OVERRIDE SWITCHES. CHANGES CLOUDED. DELTA 27	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48187	13041-20000-31668	8917 N RESEDA BLVD	91324	12	195B125   372	2770005015	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.23242	-118.53628	T24 FOR EXISTING SWIMMING SCHOOL. TOTAL NEW LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48188	16041-10000-23420	5710 E STRATFORD ROAD	90042	14	156A229   270	5485010008	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.20	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.12159	-118.19296	PV1 roof mounted solar system installation to a roof mounted solar system. Installating a central inverter rated 3.8 kw and 15 solar modules and optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48189	12041-10002-16076	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM			PC Approved	11/03/2014 12:00:00 AM	ADDRESS	34.10158	-118.3062	REVISIONS TO LIGHTING PLAN OF PERMITTED SET OF PLANS PLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48190	19041-10000-13416	16906 W SAN FERNANDO MISSION BLVD	91344	12	210B133   995	2683028035	P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.27182	-118.50017	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48191	12041-20000-10288	22952 W OXNARD ST	91367	3	177B097   515	2041020016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01, 1373.01	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	ADDRESS	34.17905	-118.62737	10.56 kw PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48192	12041-20000-22421	735 S FIGUEROA ST SPACE #-116	90017	9	129A207    65	5144009089	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	First time tenant in a shell space per applicant.  New restaurant.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48193	16041-10000-22166	301 W OLYMPIC BLVD SUITE A	90015	14	127-5A209 229	5139004026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.04182	-118.25852	PC FOR POWER AND ENERGY. T.I. FOR CHIPOTLE MEXICAN GRILL RESTAURANT IN NEWLY CONSTRUCTED AND PREVIOUSLY UNOCCUPIED SPACE.B# 16016-10000-14619	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48194	14041-20000-23443	15910 W VENTURA BLVD SUITE 720	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.15561	-118.47969	OFFICE TI SUITE 720. NEW LIGHITNG AND NEW PARTITIONS. PLAN CHECK FOR 2013 BUILDING EFFICIENCY STANDARDS. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48195	11041-20000-24127	3666 E WHITTIER BLVD	90023	14	120A229    22	5188013001	A1-1XL, C1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			11/10/2011 12:00:00 AM			PC Approved	11/10/2011 12:00:00 AM	ADDRESS	34.02451	-118.19404	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR INTERIOR REMODEL IN THE EXISTING WHOLESALE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48196	15041-10000-21997	6301 W 3RD ST	90036	4	138B177  1148	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.07243	-118.35963	Energy plan check for a historical office T.I. Main scope includes new lighting, receptacles and an additional sub panel. Total area is 3215-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48197	18041-20000-17691	11601 W WILSHIRE BLVD STE 420	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing space T.I. office space. Total area: 2020 sq ft.B#18016-10000-13118	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48198	13041-10000-35376	933 S SANTEE ST	90015	14	126A209   148	5145016034	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.03947	-118.25446	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH FLUORESCENT FIXTURES. 1332 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48199	13041-10000-23472	16622 W HAYNES ST	91406	6	180B137   440	2231013030	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.18912	-118.4954	PV1 2.2KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: SOLAREDGE SE3000A-US] [( 9) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48200	17041-10000-18560	232 E 2ND ST STE C	90012		129A213   479	5161023035							Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM			PC Approved	06/02/2017 12:00:00 AM	ADDRESS	34.0495	-118.24258	Title 24 plan check.  T.I. and change of use from coffe shop to ice cream shop.  One new subpanel with new lighting and receptacles.  Total area = 1,137       Building permit #17016-10000-04970	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48201	14041-10000-27403	616 S LORNA LANE	90049	11	132B145   269	4401012009	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	34.05657	-118.4694	PV1 Standard Plan, 7.2KW roof-mounted system including: (1) 4.2 and 3.0KW inverters, and (38) Kyocera KD255 modules interconnected through a load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48202	14041-10000-28539	5644-5654 N VAN NUYS BLVD	91401	4	174B149   694	2245006036	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Issued	10/15/2014 12:00:00 AM	ADDRESS	34.17339	-118.44835	Plan check for T-24 energy outdoor lighting Keyes Automobile 28,298 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48203	12041-10000-26401	601 S FIGUEROA ST	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Expired	03/24/2015 12:00:00 AM	ADDRESS	34.05076	-118.25881	TENANT IMPROVEMENTS IN EXISTING COMMERCIAL HIRISE. NEW 120 KVA UPS SYSTEM, NEW PANELS AND CIRCUITS FOR IT EQUIPMENT ON THE 6TH THROUGH 11TH FLOORS.. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48204	12041-10000-09113	1045 S SANTEE ST	90015	9	126A209   255	5145020009		Central				2079.00	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	ADDRESS	34.03803	-118.25612	Elevator Monitoring and Fire Alarm System	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48205	10041-20006-24663	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	"(8/4/2016)CHANGES TO AN APPROVED SET OF PLANS.  ADDING WIRE REDUCER FOR FIRE PUMP CONTRLLER FEEDERS ILSCO HYPRESS LONG BARREL COUPLINGS.  ADDITION ON 18 CIRCUITS.  05-10-2016 CHANGES TO APPROVED SET OF PLANS. CHANGES ON DELTA ""F"", ADDITIONAL OF CIRCUITS FOR MECHANICAL DAMPERS, SOKE FIRE DAMPERS, IRRIGANTION CONTROLLER, VFD  FOR CT-1, VALVE FLOAT CONTROL, AND REVISED LIGHTING FIXTURE IN CORRIDOR 117, AND UDATE CIRCUTIS ON PANEL, RLA, 1LBA, 1LLA, 3LLA, 5LLA, 2EQLA, AND REQLA. ****************PREVIOUS WORK DESCRIPTION**************************************[[[ 1/7/16 CHANGES TO APPROVED SET. DELTA 67 CHANGES ONLY. CHANGES TO SHORTCIRCUIT RATINGS OF PANELBOARDS. SHORTCIRCUIT STUDY HAS BEEN PROVIDED.]]]]]PLAN CHECK FOR LOST SET OF PLANS. RECHECK THIS ENTIRE SET AS NEW. PER BUILDING PC IN ACCORDANCE TO 2008 ENERGY CODE. PERMIT WILL BE ISSUED FOR DIFFERENCE IN INSPECTION ITEMS FROM ORIGINAL APPLICATION."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48206	18041-20000-45238	2337 N OBSERVATORY AVE	90027	4	153A201    93	5592027015	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Issued	11/28/2018 12:00:00 AM	ADDRESS	34.11452	-118.28478	PV1.  Install 9.0 kW roof mounted grid tied PV system.  (25) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48207	19041-20002-23996	15030 W BLEDSOE ST	91342	7	222B145    15	2506015016	(T)R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.30963	-118.46019	CHANGES TO APPROVED SET DELTA 1 ONLY, RELOCATION OF AC DISCONNECT AND INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48208	18041-10000-02455	19350 W BUSINESS CENTER DR	91324	12	195B117    75	2783025096	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.2312	-118.55518	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48209	17041-20000-43907	7441 W WOODROW WILSON DR	90046	4	156B177   257	2427012021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.12423	-118.35693	Plan check for AC coupled battery backup system for SFD. Existing solar on site.(2) 5kW Tesla Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48210	14041-10000-07845	965 S FEDORA ST	90006	10	129B197    26	5078003006	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.10	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM	ADDRESS	34.05375	-118.29807	T24 . New 200A service  Total area 1705 sq ft.Hotel-apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48211	14041-20000-14303	13328 W TREGO ST	91342	7	231B157    67	2582019015	RE15-1-H	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.32914	-118.42305	Roof mounted PV system with Enphase, Model number M250-60-2LL.  PV system size 3.5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48212	17041-30000-40697	633 W 5TH ST 27th Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only in existing high-rise office T.I. Total newly connected load less than 400A. Total area: 21,380 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48213	14041-20001-24886	7014 S HOOVER ST UNIT 4	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	expedite feesINSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 4.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48214	19041-10000-52030	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	01/19/2021 12:00:00 AM		Permit Finaled	12/16/2022 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR TRACK LIGHTS AS AN ACCENT LIGHTS FOR ART DISPLAY CASE IN ROOM 1402B OF LAX. AREA OF SCOPE (202)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48215	16041-20000-01215	24034 W HILLHURST DR	91304	12	186B089   449	2027046012	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	PIN	34.20524059	-118.64969508	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (32) Kyocera KU2656 Modules(1) Solaredge SE6000A Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48216	18041-20000-06727	4525 W WILSHIRE BLVD ste 100-200	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Issued	02/23/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	ti to an existing commercial building.  adding new lighting new controls to new panels, newly connected load < 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48217	16041-30001-40623	1101-1133 S GAYLEY AVE	90024	5	132B149   118	4363023033	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM			Corrections Issued	11/17/2016 12:00:00 AM	ADDRESS	34.05994	-118.44648	Plan check for Title 24 only in existing space T.I. office. Total area: 4,410 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48218	11041-10000-27566	21031 W VENTURA BLVD 101	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	PIN	34.16717222	-118.59179488	UPDATED PLANS TO REFLEX AS-BUILT CONDITIONS Dental Office Tenant Improvement. Plan check for Power & Energy. Permit was issued 11041-90000-18640	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48219	18041-20000-40490	4136 N CACHALOTE ST	91364	3	165A107   376	2172026035	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Expired	04/27/2024 12:00:00 AM	ADDRESS	34.14516	-118.59412	Plan check for a PV1 roof-mounted PV system. System size is 20.46 kWdc/15.18 kWac and consists of (66) micro-inverters, (66) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48220	18041-10000-38207	15525 W CABRITO ROAD	91406	6	189B145   115	2654040013	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM			PC Approved	10/12/2018 12:00:00 AM	ADDRESS	34.21724	-118.47082	TI IN AN EXISTING COMMERCIAL AREA. T-24 ENRGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48221	16041-10001-44984	10250 W SANTA MONICA BLVD STE. 2990	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Revision to approved set: add 2 panels with its branch circuits, revise load calculation, revise floor and roof plans per new loads, revise single line diagram due to new panels. Revised plan is originally submitted with changes noted under Delta D,2,4,5,9, and final approved plan is noted under delta-10 <<Full PC for 1st time Tenant ""Tender Green"" Ste. 2990.  Install new electrical equipments,,  total affected area: 2,630 sq.ft>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48222	17041-20001-13844	18035 W BURTON ST	91335	12	192B125   710	2101020017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.22001	-118.52641	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48223	14041-10000-01394	12400 N MASON AVE	91326	12	216B113     1	2701002068	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.29257	-118.58291	plan check for T24 PART 6 ENERGY only . PROJECTED AREA IN OUTDOOR LIGHTING WORK IS APPROX. 265,027 SQ FT. PORTER RANCH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48224	19041-20000-06733	217 W AVENUE 37	90065	1	144A223   100	5451010009	[T][Q]RAS3-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1990.00	Electrical	Electrical	Apartment			02/25/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Issued	02/06/2020 12:00:00 AM	ADDRESS	34.08995	-118.21225	Plan check for power and energy for new 800A service with (7) panels with loads. T24 included, total square footage = 2791 sfB#18010-10000-05134	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48225	14041-20000-09281	17953 W VENTURA BLVD	91316	5	171B129   191	2162006002	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.16441	-118.52369	TI  for commercial classroom space in a two story commercial building. Plan check for Title 24 due to changes in lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48226	19041-20000-16737	7433 N IRONDALE AVE pv1	91306	3	186B109   583	2113010010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.20564	-118.58532	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48227	16041-10000-30631	1529 W 58TH ST	90062	8	108B193  1184	5003031022	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	33.98982	-118.30317	ROOF MOUNTED PV PV1 SFD TOTAL SYSTEM SIZE 3KW AC. USING TOTAL OF 15 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48228	18041-10000-41326	6307 N WILLOW CREST AVE	91606	2	177B177    74	2414017022	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.1851	-118.3628	PLAN CHECK FOR ROOF MOUNTED 6.48KVA PV SYSTEM CONSISTING OF AC 18 MODULES (SUNPOWER SPR-X22-360-D-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48229	19041-20000-17981	8025 N SEPULVEDA BLVD	91402	6	189B145   299	2654037009	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Apartment			05/14/2019 12:00:00 AM			PC Info Complete	11/15/2019 12:00:00 AM	ADDRESS	34.21638	-118.4664	PLAN CHECK FOR 1600A SERVICE, (70) 100A PANELS, (2) 200 A PANELS, A 60A PANEL, A 125A PANEL, (2) 40HP ELEVATORS, A 600A PANEL, A 1000A PANEL. T24 INCLUDED TOTAL SQUARE FOOTAGE = 79,429 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48230	18041-20000-27319	7127 N CANOGA AVE	91303	3	183B105   302	2111028032	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			Verifications in Progress	08/21/2018 12:00:00 AM	ADDRESS	34.19999	-118.59788	Plan check for power and energy in existing building for change to use for agriculture newly connected load exceed 400A. Building is feeding by several services 120/240 3 phase 4w Delta. Total area: 221 sq ft. Agriculture area excempt from Title 24. B#18016-20000-13343	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48231	14041-20000-15967	3103 S LA CIENEGA BLVD Unit B	90016	10	123B173  1531	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.02996	-118.37335	Partial T.I. to existing building.  Install new general lighting in office area.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48232	15041-20000-17679	19339 W BLYTHE ST	91335	3	189B117   398	2105013011	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2015 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.21496	-118.5552	Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (2) inverters, (1) load center, and (36) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48233	11041-20000-16191	1262 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/02/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	ADDRESS	34.02523	-118.29341	New 3.23 Kw PV System for Apartment Bldg #1262	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48234	15041-20000-29516	21217 W DE LA GUERRA ST	91364	3	171B105   532	2167004006	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.16479	-118.59505	Plan check for PV roof mounted system in multi-family complex. System size: 5.0kW with 25 modules and 1 inverter(5.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48235	10041-10000-14649	330 W WASHINGTON BLVD A , B, C,-D	90292	11	105A147   253	4225003005	C2-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM			PC Approved	08/17/2010 12:00:00 AM	PIN	33.98038877	-118.46355239	T-24 lighting plan check and emergency lighting for retail spaces.  See spaces A, B, C and D.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48236	13041-10000-22330	380 W WORLD WAY SPACE 33	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	PANDA EXPRESS AT LAX SPACE 33. APPROVED SET OF PLANS FOR T24 UNDER APPLICATION # 13041-10000-02906. THIS APPLICATION IS FOR FULL PLAN CHECK FOR FIRST TIME TENANT. NEW PANDS EXPRESS. PC FOR POWER UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48237	14041-10000-13039	14006 W RIVERSIDE DR #63	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	PLAN CHECK FOR ENERGY ONLY FOR EXISTING FOOTLOCKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48238	13041-20000-19925	10950 W BLOOMFIELD ST	91602	4	165B173   468	2423020012	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			07/26/2013 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.14907	-118.36968	NEW CONSTRUCTION OF 49 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED. LOW RISE RESIDENTIAL. PC FOR POWER ONLY. T24 FOR PARKING GARAGE. NON METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48239	18041-10000-19185	1423 N TAMARIND AVE	90028	13	147A191   133	5545014014	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.09633	-118.31918	PLAN CHECK FOR T-24 ENERGY ONLY.CONVERT EXISTING 3 UNIT APARTMENT UNITS TO CHILD CARE (AGES 2-K).INSTALL A NEW 400 AMP SERVICE, 3 PANELS AND CIRCUTS & LIGHTS.PERMIT #'S: 18016-10K-00057, 18016-10K-00058, 18016-10K-10411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48240	14041-20000-33268	5120 N WHITSETT AVE	91607	2	171B165   728	2356020006	R1-1, RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.16366	-118.40507	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6.6kW (3+3.6). Ungrounded system.33 255W pv modules across 4 strings (inv1 - 9+9; inv2 - 8+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48241	18041-10000-17519	18401 W NORDHOFF ST	91325	12	198B125   257	2764013012	(T)(Q)R3-1	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Closed	02/27/2020 12:00:00 AM	ADDRESS	34.23566	-118.53392	PC FOR POWER AND ENERGY FOR A NEW  5 STORY 146 UNIT MIXED USE- RETAIL AND APARTMENT BUILDING OVER A SUBTERRANEAN PARKING. INSTALLING A NEW 4000A 120/208 3PH SERVICE, NEW DISTRTIBUTION BOARDS, NEW PANELS, AND CIRCUITS. TOTAL AFFECTED AREA IS 115103 SQ. FT.  B#18010-10000-01024	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48242	16041-20001-33711	5159 N COSTELLO AVE	91423	4	171B153   527	2269008006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM			PC Approved	10/14/2016 12:00:00 AM	ADDRESS	34.16425	-118.43839	RSES expedited plan check fee per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48243	19041-20001-16303	2576 N BASIL LANE	90077	5	154-5A151 189	4379005***	RE15-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2019 12:00:00 AM			PC Approved	05/24/2019 12:00:00 AM	ADDRESS	34.1185	-118.44782	05-24-2019 Changes to an approved set of plan, changes include reuse exisiting service and panel. All changes has been clouded Plan check only. ********provious Work description********Plan check for Battery back up system, Battery size 13.5KWh install into existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48244	10041-20000-05243	6269 N VAN NUYS BLVD	91411	6	178-5A151 192	2241012003	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM			PC Info Complete	04/09/2010 12:00:00 AM	PIN	34.18430357	-118.44915121	RESTAURANTE T.I.ENERGY, EMERGENCY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48245	19041-10000-33036	16010 W SUNBURST ST	91343	12	195B141    93	2672027007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.23443	-118.48108	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15 MODULES (Q-CELL 285) , 23 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 4.275KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48246	11041-10000-05227	606 E 76TH ST	90001	9	099B205    94	6023017900	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	33.97105	-118.26477	REMODELING OF MULTIPUPOSE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48247	19041-10000-39063	3200 W JEFFERSON BLVD	90018	10	120B185   855	5044007008	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.02547	-118.33065	ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT COMBINING THREE RETAIL STORES  INTO ONE. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 1727-SQ FT.BLD #: 19016-10K-19152	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48248	15041-20000-04332	16238 W RAYMER ST BLDG 12-UNIT B	91406	6	189B137    19	2205029037	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.21771	-118.48681	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS, TRANSFORMER AND PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4951.  SCOPE OF WORJ TO BE PERFORMED IN BUILDING 12 UNIT B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48249	14041-20000-08348	3101 W VENICE BLVD	90019	10	126B189   256	5072034028	C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Apartment			03/28/2014 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.04375	-118.31795	New 3-story 48 apartment over parking garage in Methane Zone.  Install new 1200A service.  Plan check for power and energy.Note: Submit variance to separate fire alarm	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48250	18041-20000-48556	11350 W PALMS BLVD	90066	11	117B157   350	4249026028	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	05/18/2020 12:00:00 AM		Permit Finaled	11/17/2021 12:00:00 AM	ADDRESS	34.01769	-118.42601	Plan check for power and energy for  1600A service, lighting, receptacle and associated load. Total area:  28,178 sq ft. B#18010-20000-06288	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48251	18041-20000-43867	19020 W KINGSBURY ST	91326	12	207B121   552	2728014015	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.26291	-118.54717	pv1install roof mounted pv system sized 12.9KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48252	14041-20001-18183	19112 W HALSTED ST	91324	12	201B121   669	2762010019	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.24457	-118.54995	Modifications to approved set. Reduction in number of modules from 20 to 18.  $0 plan check fee is due to Senate Bill SB-1222.  (((PV1Microinverter standard plan.Install roof-mounted solar array on SFD. System size: 3.87kW(18) EnPhase M215 IG microvinverters(18) Solar World SW250 Poly pv modules)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48253	12041-10000-26509	6424 N DUNLO PL	91307	3	180B085    88	2032005007	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.18728	-118.65984	6.0 kw INSTALL ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR A SINGLE FAMILY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48254	15041-20002-06350	6320 N TOPANGA CANYON BLVD G-1690	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	08/13/15 Changes to an approved set of plans. Delta 3 changes. Changes to the location of area controls and rewiring of some circuits.  (((Plan check for power and Title 24 (energy).  Total area = 6,575 sq. ft.T.I. to (new) Wokcano restaraunt.  First time tenant.  3 new panels, 1 1125 KVA transformer, and lighting + equipment loads.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48255	18041-20000-30325	18455 S FIGUEROA ST	90248	15	060B201    20	7339008034	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM			Reviewed by Supervisor	12/13/2018 12:00:00 AM	ADDRESS	33.86353	-118.28198	Plan check for power and energy for existing Electric Car Manufacturer (Faraday Future) T.I. adding new equipment. Total area: 350 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48256	19041-20000-40678	6521 S BRYNHURST AVE	90043	8	105B185  1323	4006020010	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			10/08/2019 12:00:00 AM	11/10/2020 12:00:00 AM		Permit Finaled	04/01/2022 12:00:00 AM	ADDRESS	33.97998	-118.33402	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48257	19041-10000-35199	3400 W OLYMPIC BLVD 2nd floor	90019	10	129B193   344	5081031025	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Approved	09/05/2019 12:00:00 AM	ADDRESS	34.05245	-118.31249	Power plan check for a medical office T.I. Scope includes new lighting and equipment with a total medical office area of 2,088 SQ FT. Note. Portion of permit fee is paid under 19041-10000-30213(((PC FOR T24 ONLY SCOPE OF WORK IS CHANGE OF USE FROM RETAIL TO OFFICE ON THE ENTIRE 2ND FLOOR IN A LOW RISE BULDING. SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 9750 SQFT.BUILDING PERMIT: 19016-10000-08504 )))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48258	16041-20000-02856	5846 W VIRGINIA AVE	90038	13	144B189   527	5534017019	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.09167	-118.31734	Plan check for energy only. Installing outdoor lighting for parking lot. 7,500sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48259	19041-10001-35391	6101 N MAURY AVE	91367	3	177B085   253	2032019021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM			PC Approved	09/18/2019 12:00:00 AM	ADDRESS	34.18154	-118.66112	NEW ROOF MOUNTED 20.44KW PV SYSTEM WITH (56) PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48260	13041-20001-23924	10029 N GIERSON AVE	91311	12	204B101   548	2745007024	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.25273	-118.61163	((EXPEDITE FEES))PV1 TRANSFORMERLESS INVERTER. 28 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 6.0KWAC. 3 STRINGS FOR 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48261	14041-10000-06360	216 E C ST	90744	15	027B209   113	7418030005	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	33.77269	-118.26016	T24, REMOVING HID LIGHT FIXTURES WITH NEW FLORESCENT FIXTURS. TOTAL AREA 1247 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48262	11041-20000-18777	12199 W VENTURA BLVD	91604	2	162B165    60	2367017010	C2-1L, P-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM			PC Approved	09/28/2011 12:00:00 AM	ADDRESS	34.14344	-118.39842	T.I.  Existing retail space.  Remoel of the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48263	18041-10000-42490	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.02201	-118.28947	PC FOR ADDITION OF UPS AND POWER CONDITIONER TO BASEMENT OF USC BUILDING. CONNECTING TO EXISTING 3000A SERVICE AND A 4000A GENERATOR TO PROVIDE EMERGENCY POWER. SCOPE INCLUDES ADDING A 1000KVA UPS TO EXISTING DISTRIBUTION SYSTEM WITH ASSOCIATED EQUIPMENT - SEE SHEET E-600 FOR SINGLE LINE CHANGES - COPY OF EXISTING APPORVED SET OF PLANS HAVE BEEN ATTACHED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48264	16041-10003-02487	3900 W 6TH ST	90005	10	135B193   885	5503030001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	11/23/2019 12:00:00 AM	PIN	34.06325314	-118.30807759	Change to an approved set by remodeling lighting plan, power plan and service load calculation. All changes under delta-4 only. original plan checker Francies********ORIGINAL SCOPE********PC FOR POWER AND ENERGY. TI FOR RESTURANT. NO CHANGE OF USE, 2-STORY WITH ONE LEVEL BASEMENT, SMT LA RESTURANT. ADDING 6 NEW 200A PANELS AND TWO 45 KVA TRANSFORMER  TOTAL AREA 13660 SQ (INDOOR AND OUTDOOR).B# 15016-10000-25358	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48265	15041-30000-39697	20530 W WYANDOTTE ST	91306	3	186B109   951	2113022011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.20299	-118.58108	Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect new inverter and modules with existing PV system.  Total system size = 6.7 kWac (3 kWac new).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48266	14041-10000-26289	605 S NORMANDIE AVE	90005	10	135B193   873	5502032005	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM			Reviewed by Supervisor	10/03/2014 12:00:00 AM	ADDRESS	34.06323	-118.30053	Power plan check only; contractor replacing (3) 400 Amp to (1) 1000 Amp new services for a commerical building including hotel and retail. all load remain the same.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48267	12041-10000-18879	400 WORLD WAY Terminal 4-Space 4K	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	33.94221	-118.40701	New Tenant.  Full Plan check for Power and Energy for Homeboy Bakery Restaurant (Per applicant).  LAX Terminal 4, Space 4K.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48268	10041-10000-11243	15840 W MONTE ST #105	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	06/21/2010 12:00:00 AM		Permit Finaled	08/04/2010 12:00:00 AM	ADDRESS	34.31015	-118.47604	REMODELING OFFICES ON THE 1ST AND 2ND FLOORSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48269	16041-10000-44584	10250 W SANTA MONICA BLVD # 1620	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""La Colombe"" Ste. 1620.  Install new Xrfmr, and  panels, total area 1189 sq.ft. *New connected load 104A, demand lolad 80A to DB-ELA41"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48270	10041-20004-25118	1200 S SANTA FE AVE	90021	14	123A217   315	5166007011	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Info Complete	11/13/2013 12:00:00 AM	ADDRESS	34.02944	-118.22979	((CHANGES TO APPROVED SET. CHANGES CLOUDED DELTA 1. 100A UNIT PANELS. CHANGES COVERED UNDER DELTA 3. COMPLY WITH DEPARTMENT ORDER effective date11/18/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48271	16041-20000-43731	111 E UNIVERSAL HOLLYWOOD DR 19th FLR	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.13855	-118.36112	(RE PLANCHECK DUE TO DEPARTMENT ERROR, PERMIT UNDER THIS APPLICATION)   PC FOR TITLE 24  (HIGH RISE BLD)ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 20048 SQ.FT(16041-10000-42174  REFUNDED APPLICATION)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48272	17041-10000-07060	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Issued	08/24/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC FOR A NEW FIRE ALARM SYSTEM FOR A HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES 2087 FA DEVICES, AND 52 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48273	19041-20000-41543	20714 W BLUEBIRD CT	91326	12	219B109   502	2701108006	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.29726	-118.58489	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.725 KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48274	19041-10000-02231	545 S SAN PEDRO ST	90013	14	127-5A213 295	5148013006	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.04311	-118.24486	$0 Fees Due, Department Error to replace Building permit number 17010-10002-05068 to Electrical permit #19041-10000-02231.Electrical Plan Check & Permit Fees were paid under the above permit number.<<<TI IN AN EXISTING EMERGENCY HOMELESS SHELTER. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48275	12041-10000-04072	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	New Fire alarm system for Tom Bradley terminal @ LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48276	11041-20000-19746	127 S SAN VICENTE BLVD Bulletin-71TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta # 71 TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48277	13041-20000-16789	251 S RENNIE AVE	90291	11	111B141   313	4240006031	RD2-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	33.99865	-118.4741	PV2 FOR APARTMENT COMPLEX. TOTAL SYSTEM SIZE: 1.750 KWDC. 7 PANELS WITH MICROINVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48278	16041-10000-42835	10957 W CALVERT ST	91606	2	177B173   760	2414003021	C2-1VL, RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM			PC Info Complete	04/26/2017 12:00:00 AM	ADDRESS	34.18135	-118.36953	8 UNIT APARTMENT OVER 1 LEVEL GARAGE. NEW 120/240 V 3 PHASE 4 WIRE 600 A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48279	16041-10000-27431	12740 W ARROYO ST BUILD. D	91342	7	219B161   249	2525027014	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.29585	-118.41002	Plan check for T-24 only.  Remove indoor and outdoor HID fixtures and replace with new LED fixtures. Affected area: 44,144 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48280	13041-10004-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	CHANGES TO AN APPROVED SET OF PLANS FOR A SCHOOL. ALL CHANGES ARE CLOUDED UNDER DELTA 26. CHANGES INCLUDE RECONNECTING NEW AND EXISTING LOADS TO TWO EXISTING SERVICES. ALSO, ADDING A NEW 500A CIRCUIT BREAKER, NEW 225KVA TRANSFORMER, AND A NEW 600A DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48281	13041-10001-05477	20750 W VENTURA BLVD	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Approved	03/11/2013 12:00:00 AM	ADDRESS	34.16638	-118.58506	changes to approved set of plans:clarified luminaire schedulechanged notes to emphasize which emergency lights are existing. added extra bugeyes per supervisor correctionsT24 for non-emergency lighting in corridor and lobby for 2-story office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48282	10041-20000-21553	5303 N LANKERSHIM BLVD	91601	4	171B173   291	2350016006	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Issued	12/22/2010 12:00:00 AM	ADDRESS	34.16717	-118.37623	replace lighting in fire damage restaurant /bar	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48283	12041-10000-06511	1809 W 11TH ST	90006	1	129A203    73	5136010026	CR-1-HPOZ	Central	Westlake	Pico Union		2095.20, 2098.20	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.04901	-118.27769	Fire alarm system with 53 devices in an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48284	19041-10000-27486	12121 N BALBOA BLVD	91344	12	216B133    73	2606001014	[T]RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.29149	-118.50226	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48285	13041-10000-20883	800 S FIGUEROA ST SUITE 1270	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			Corrections Issued	08/06/2013 12:00:00 AM	ADDRESS	34.04771	-118.26116	TITLE 24 PLAN CHECK ONLY.  948 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. HIGH RISE. WORK ON SUITE 1270.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48286	19041-20000-31388	3710 N WINFORD DR	91356	3	162B121   118	2177043026	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.13618	-118.55116	PV1. INSTALL 8.06 KWDC/ 6.0 KWAC SYSTEM SIZE SOLAR ROOFMOUNTED SOLAR SYSTEM WITH (26) MODULES AND OPTIMIZERS (P320) AND (1) INVERTER (SE6000H-US) ON EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48287	19041-10001-15871	1500 S WESTWOOD BLVD	90024	5	132B153   972	4325020001	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM			PC Approved	11/20/2019 12:00:00 AM	ADDRESS	34.05401	-118.4404	PLAN CHECK FOR CHANGES TO AN APPROVED SET OF PLANS.  NOTE: CHANGES UNDER DELTA 3 ONLY. SCOPE OF WORK INCLUDES: CHANGE OF LIGHTING LAYOUT AND FLOOR LAYOUT.*Full PC for Tenant Improvement to existing Restaurant. existing service. scope of work area 1015SF.*	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48288	10041-20000-07842	624 S GRAND AVE # 1709	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	07/08/2010 12:00:00 AM	PIN	34.04778206	-118.25563275	ENERGY PLAN CHECK  UNIT # 1709	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48289	15041-10000-34982	960 W 62ND PL	90044	9	105B197  1072	6004015019	C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	ADDRESS	33.98261	-118.29095	T-24, TO AN (E)  APARTMENT BUILDING. SCOPE INCLUDES NEW FIXTURES IN THE COMMUNITY SPACE, PC FOR ENERGY ONLY. TOTAL SQ. FT. 3900. NOTE: THIS IS A PLAN CHECK ONLY INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT #: 15041-10000-31299.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48290	12041-10000-11879	8601 S LINCOLN BLVD 1-405	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			PC Info Complete	05/23/2012 12:00:00 AM	ADDRESS	33.95939	-118.41943	T.I. for LA Fitness to add a fire alarm to an existing shell building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48291	18041-20000-00702	18400 W BURBANK BLVD	91356	3	174B125   488	2160010037	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	PIN	34.17045874	-118.53384937	Plan check for power and energy. Project site is a new 6-story parking structure. Work includes a 2,000 Amp service and a total lighting area of 195,000 sq. ft.Note: Building application has been generated under 18010-10000-00353	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48292	12041-20000-10230	6600 N TOPANGA CANYON BLVD 97-B	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24 and emergency egress lighting plan check for space 97B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48293	17041-20000-17718	3434 S GRAND AVE 3rd FL	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.01912	-118.27658	Plan check for energy only. New lighting (incl. emergency) for office on third floor mezzanine. 1,676sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48294	14041-10001-10040	2450 W RIVERSIDE DR	90039	13	150A209   179	5438005017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.10517	-118.25568	((5/16/2014- ADDED 2 MODULES TO EXISTING SYSTEM))ROOF-MOUNTED 1.5KW PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48295	13041-20000-06128	7650 W IMPERIAL HWY	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	33.93066	-118.4334	FIRE ALARM SYSTEM HYPERIAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48296	17041-10000-21397	6500 W WILSHIRE BLVD 15TH  FLR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.06371	-118.3703	Title 24 plan check.  T.I. to office space in existing commercial highrise building.  New lighting and receptacles in rooms 1523, 1524, 1525, and 1507.  Total area = 640 sq. ft.       Building permit #17016-10000-14500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48297	10041-20000-01368	810 S FLOWER ST 1st floor	90017	9	129A209   164	5144020040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	03/10/2011 12:00:00 AM	ADDRESS	34.04692	-118.26018	Work in high rise residential building on first floor changing it to office area.  Request to seperate fire alarms submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48298	14041-10004-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			06/14/2017 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	33.95713	-118.3847	CHANGES TO APPROVED SET. CHANGES STILL ALL CLOUDED DELTA 6. UNDER THIS APPLICATION, CHANGE IS ONLY TO INCLUDE AN EXISTING 200A SERVICE TO 5000A TAP BOX. UPDATED LOAD CALCULATIONS AND FEEDER DIAGRAM PROVIDED. PC ONLY, PERMIT UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48299	14041-10000-00014	1043 S TOWNE AVE	90021	14	124-5A211 324	5132010039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.03342	-118.25043	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 390 SQ FT. REPLACING TOTAL OF 3 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48300	11041-10000-15800	1874 S WESTERN AVE	90006	10	126B193   874	5074015047	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.04037	-118.3088	T.I.  Existing 7-11 store.  Replacing 36 light fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48301	15041-10000-11709	2445 E 12TH ST Ste C	90021	14	120A217    96	5168003013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.02277	-118.22852	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48302	14041-10000-19099	8501 W PICO BLVD	90035	5	132B173  1242	4332028038	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.05355	-118.37643	PLANCHECK FOR T24 ENERGY.  BANK OF AMERICA  ATM LIGHTING. 500 SQFT, EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48303	18041-20001-37378	7701 N WOODLEY AVE	91406	6	186B137   423	2205010905	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.20948	-118.48389	SUPPLIMENTAL PC FOR DELTA 2 CHANGES ONLY. CHANGING ALL 880-Y COPPER FEEDERS TO A800-Y ALUMINUM FEEDERS. <<<<<<<<Plan check for power only. Project site is an existing commercial building (existing hangar at Van Nuys airport). Project scope is a new 800 amp serive at 4.8KV feeding a 2,000-amp switchgear which will re-feed existing distribution equipment and loads.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48304	19041-20000-28314	955 S MARIPOSA AVE	90006	10	132B197  1170	5078002032	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	34.05401	-118.29907	Plan check for PV roof mounted system, PV system size: 13KW DC, 11.91KW AC with 40 PV Modules and 1 inverter(11.4KW) connected to 600A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48305	18041-20000-18771	13088 W MONTAGUE ST	91331	7	198B161   710	2626016060	(T)(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.24283	-118.41758	Plan check for a PV1 roof-mounted PV system. System size is 5.8 kWac and consists of (25) modules, (25) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48306	11041-10001-00229	2101 E PACIFIC COAST HWY	90744	15	033B213    10	7428007003	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Info Complete	12/10/2012 12:00:00 AM	ADDRESS	33.79173	-118.23549	REPLACE AN EXISTING FIRE PUMP SYSTEM IN THE NORTH PLANT OF TESORO REFINARY. (((12-10-12  deleting interlock between main 200 amps BRKRS )))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48307	16041-10000-39307	1010 W KNOX ST	90502	15	057B197    30	7351034072	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	33.8541	-118.29433	T-24, PC FOR ENERGY ONLY. INTERIOR T.I. TO (E) OFFICES IN A  (E) WAREHOUSE BLDG. SCOPE INCLUDES ADDING LIGHTS AND RECEPTACLES FOR AN OFFICE AND WAREHOUSE SPACE. TOTAL AFFECTED AREA IS 48982 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48308	13041-20000-23818	348 S ARDEN BLVD	90020	4	135B189   371	5505018002	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Expired	11/12/2015 12:00:00 AM	ADDRESS	34.06745	-118.32564	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.25KW. 25 MODULES AND 1 INVERTER. WILL UPGRADE TO 200A SERVICE ON A SEPERATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48309	11041-10000-09948	879 W 190TH ST 4TH FL	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	33.85951	-118.28963	Interior tenant improvements for an office bldg. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48310	17041-10000-20168	3690 S MOTOR AVE	90034	5	120B165  1121	4314007900	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.02304	-118.40573	TItle 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48311	14041-10000-28820	5700 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.06218	-118.35303	Plan check for power and energy. Change of use from office to restaurant. Newly connected load greater than 400 amps. 5 story building. Work on 1st floor. Area = 2063 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48312	17041-20003-03783	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.30155	-118.46112	3/13/2018changes to an approved set of plans.  changes to light fixture types in corridor and retail spaces.  plan check for energy only. this is plan check only.(((02/02/2018 Plan check for a lost set of plans. Scope of work has not changed.*****Previous Work Description*****ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 3366.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48313	17041-20001-20807	8560 N TUJUNGA AVE	91352	6	192B169   252	2632008009	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.22512	-118.38032	DELTA 1 Changes to approved plans.=Plan check for power and energy. Redoing electrical for fire damaged commercial warehouse. New 800A 120/240 3ph 4w. New lighting (incl. emergency) - 8,600sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48314	13041-10001-34451	1751 W 36TH PL	90018	8	120B193  1339	5041014037	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.02209	-118.31047	Expedited RSES plan check per applicant request.{{PV1, Install a 2.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48315	12041-20003-22577	7270 W MANCHESTER AVE	90045	11	096B157   625	4119026042	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Apartment			09/10/2014 12:00:00 AM			PC Approved	10/22/2014 12:00:00 AM	ADDRESS	33.95959	-118.42143	Changes from previously approved plans to As-Built plans.  Changes include addition panel, circuits, and recalculation.  All changes indicate by DELTA 13 and DELTA 14 as shown on plans.   No change in Title 24 calculation.Note:  The approved plans will be submitted for reference before the plans assign, contact applicant Donald Warren.***** Previous Description *****NEW 6 STORY 260 UNITS APARTMENT BLDG WITH 3 LEVELS UNDERGROUND PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48316	12041-10001-02715	4501 W COLORADO BLVD (B-6)	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM			PC Approved	11/01/2012 12:00:00 AM	ADDRESS	34.14246	-118.2705	DELTA 9 REVISIONS TO PERMITTED SET OF PLANS; CHANGES ON EACH SHEET ARE CLOUDED AND ATTACHED TO THE SET OF PLANS ARE THE LIST OF CHANGES FOR EACH SHEET. CHANGES ARE COSMETIC SUCH AS THE LIGHTING CHANGES DUE TO FURNITURE LAYOUT AND REMOVAL OF HAND DRYERS IN THE REST ROOMS THROUGHOUT THE BUILDING.(((((((((New 5-Story, 87,700 sf Type I-B Office Building (BAXTER B6). EPC is for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48317	16041-20000-39799	8065 N WEBB AVE # C	91605	6	189B169    98	2310008003	C2-1VL-CUGU, M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.21748	-118.38966	ti to an existing commercial building adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 1726.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48318	13041-20000-24916	1300 N SEPULVEDA BLVD bldg B	90049	5	144B141    26	4368001015	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Info Complete	09/11/2013 12:00:00 AM	ADDRESS	34.08696	-118.47442	energy plan check building B classrooms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48319	14041-20000-22475	8111 N IRONDALE AVE	91306	3	189B109   154	2108008009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.21727	-118.58477	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(14) Kyocera #KD255GX-LFB3 pv modules(14) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48320	16041-20000-10316	5447 N WHITE OAK AVE	91316	5	174B129   980	2162016083	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Apartment			03/24/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.16986	-118.51874	Plan check for a PV2 roof-mounted PV system. System size is 20 kWac and consists of (2) inverters, (79) modules, (2) combiner boxes, and (1) load center.Note: This PV system is 1 of 2 that will be installed on this building. This system is interconnecting into meter #49412. System 2 can be found under application 16041-20000-10317.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48321	18041-20000-21546	6200 N CANOGA AVE #105	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.1833	-118.59719	Plan check for Title 24 only. Project site is an existing tenant space in a 4-story commercial building. Project scope is a tenant improvement. Total lighting area = 3,749 sq. ft.Note: Building application has been generated under 18016-20000-03950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48322	12041-10000-15811	8950 N GLENOAKS BLVD	91352	2	195B173   149	2408005031	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	08/23/2012 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	34.2319	-118.36828	Plan check for power and energy. Change of use from industrial to catering. 7489 indoor sqft and 25196 outdoor sqft. Commercial low rise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48323	19041-10000-46014	358 W 38TH ST	90037	9	117A203   152	5122027001	M1-2, [Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Closed	07/10/2020 12:00:00 AM	ADDRESS	34.01475	-118.27886	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS A NEW FIRE ALARM PANEL, COMMUNICATION PANEL, AND 6 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48324	11041-10000-26595	8130 W 3RD ST	90048	5	138B173   957	5511029018	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.07214	-118.36698	PLAN CHECK T24 ENERGY FOR EXISTING RETAIL STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48325	15041-20000-07139	6600 N TOPANGA CANYON BLVD #8	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			Corrections Issued	03/11/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for T-24 only for shoe place. Total area: 4051 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48326	19041-10000-45799	8155 N RESEDA BLVD	91335	12	192B125   802	2103007011	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.21921	-118.53641	REMOVE HID FIXTURES AND REPLACE WITH  LED FIXTURES- T/24 ONLY.. TOTAL AFFECTED AREA IS 6000 SQ. FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48327	10041-10000-16870	1325 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05147	-118.22461	Solar voltaic system installed on the roof of the building.  Consists of  14 modules,  14  A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48328	10041-10000-03940	1835 S STONER AVE	90025	11	126B149   991	4262023900	OS-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	04/07/2010 12:00:00 AM	ADDRESS	34.03846	-118.45325	replace existing sport lighting . wattage subject to be  verified by inspector ROSE. wattage shall be lesser or equal but no marthan old lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48329	18041-20000-35867	15230 W PARTHENIA ST #1 -#41	91343	6	195B145   561	2654022017	(T)(Q)RAS4-1VL/(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Apartment			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	34.22811	-118.46439	Plan check for new fire alarm system for new 41 units multi-family 4 story building. Total fire alarm devices: 144 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48330	18041-10000-05439	6101 W IMPERIAL HWY	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	33.93236	-118.39253	PC FOR TI-24 ENERGY ONLY FOR INTERIOR OFFICE TI ON 2ND FLOOR OF EXISTING KOREAN AIR CARGO FACILITY.INSTALLING NEW PANELS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 13640 SQ.FT. B#17016-10000-37641	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48331	15041-10000-30050	12073 W VENTURA PL	91604	2	165B165  1214	2368002013	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.14489	-118.39502	PC FOR POWER. NEW SERVICE 600A, 120/240 3 PHASE 4WIRE. MIXED USED APARTMENT AND  COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48332	16041-10000-07374	777 S SANTA FE AVE ANNEX	90021	14	124-5A217 270	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.03354	-118.23024	Installation of new fire alarm system in Ford Factory.  This is for ANNEX	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48333	17041-10000-08037	1318 E 7TH ST 524	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.03608	-118.24052	"T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 8998 SQ. FT. ""Comply with department order effective date 06/21/2006. Permit will expire 30 days from issuance date"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48334	16041-10000-27569	1999 S AVENUE OF THE STARS 4TH FLR	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	PC FOR TITLE 24. TOTAL AREA 8930 SQFT.  ENERGY ONLY, NEW LIGHTING AND RECEPTACLES LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48335	18041-10002-46954	1550 N RISING GLEN ROAD	90069	4	147B169   342	5561002035	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.10004	-118.38417	CHANGES TO AN APPROVED SET OF PLANS. CHANGES IN DESIGN FOR SOLAR MODULES. REPLACING MODULES FROM SOLARCITY STANDARD SC325 TO SC330.NOTE: PERMIT IS PAID UNDER PCIS#18041-10000-46954	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48336	19041-20000-41040	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48337	19041-10000-38455	3882 N CORBIN AVE	91356	3	162B113    70	2180013019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.14055	-118.56478	[eplan] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH  41 MODULES USING P320 OPTIMIZERS CONNECTED TO NEW 200A SERICE PANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48338	13041-10001-32634	701 WORLD WAY parking	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	33.94352	-118.40045	03/28/17Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding battery packs for lights in the elevator lobby. Note: permit is paid under PCIS#13041-10000-32634	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48339	18041-10000-06805	7230-7232 1/2 N OWENSMOUTH AVE	91303	3	186B105  1011	2111019007	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.20198	-118.60138	PC FOR ENERGY ONLY, TI TO AN (E) RETAIL. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3226.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48340	18041-10000-01026	717 S MORENO AVE	90049	11	126B141   235	4264007051	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Issued	06/12/2018 12:00:00 AM	ADDRESS	34.04281	-118.48391	"Install (2) New Battery back-up system 9.8 kWh each  LG-RESU10 on a single family dwelling (PV system is existing), also adding (1) 125A subpanel ""back-up panel""<<<<<<12.14.2016 - Plan check for modifications to approved set. Change inverters to more modern version of same brand, type (ungrounded), and rating (SMA Sunny Boy 7.0-US ==> SMA Sunny Boy 7000TL-US). Changes clouded.======pv1install roof mounte pv system sized 14kw interconnected with msp.>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48341	15041-20001-43777	15465 W EL CAJON ST	91342	7	222B145   174	2604012006	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM			PC Approved	01/04/2016 12:00:00 AM	ADDRESS	34.30505	-118.46888	EXPEDITE PER APPLICANTPV1, rooftop solar installation 6kW AC interconnects with 400MSP(28) KU2656ZPA(1) PVI-6000-OUTD-US-Z	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48342	17041-10000-19298	380 WORLD WAY Gateway-F/A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	07/27/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	"New Fire alarm system at the ""Gateway"" Midfield Satellite Concourse of LAX. (4) panels, (311) devices"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48343	19041-20002-11120	23100 W AVENUE SAN LUIS	91364	3	171B097   954	2074020035	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Apartment			10/18/2019 12:00:00 AM			PC Approved	10/18/2019 12:00:00 AM	ADDRESS	34.16191	-118.62958	10/18/19CHANGES TO APPROVED SET DELTA 2 ONLY CHANGES TO SHORT CIRCUIT CALC AND REMOVE CIRCUIT BREAKER.<<<PV2.  Install 141.99 kW DC / 129.74 kW AC roof mounted grid tied PV system.  (389) modules with (4) 33.3 kW rated inverters.  Supply side connection.  $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48344	15041-10002-14901	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	04/15/16Changes to an approved set of plans, Changes include deleting the occupant sensors due to having a time clock and being a 24 hour gym. (((04/13/16Changes to an approved set of plans. All changes are clouded and under delta 6. Changes include removing/adding lighting fixtures, adding smoke doors, receptacles, revising title 24 forms, and revising load calculations for panels 'MSB', and 'DP1.' Also new lights for staircase and common areas. )))(((((PLAN CHECK FOR POWER AND ENERGY FOR NEW GYM IN EXISTING MALL. 800A DISTRIBUTION FOR GYM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48345	19041-30000-14907	10635 W SANTA MONICA BLVD Suite 165	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Info Complete	04/23/2019 12:00:00 AM	ADDRESS	34.05353	-118.43031	Plan check for Title 24 only. Project site is an existing tenant space is a commercial building. Project scope is a tenant improvement. Total lighting area = 2,655 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48346	12041-20000-25361	13174 W ORTLEY PL	91401	2	180B157   776	2326022010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.18823	-118.42072	Plan check for PV system. Roof mounted. SIngle family dwelling. Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48347	14041-20000-24926	10250 W CONSTELLATION BLVD SUITE 1030	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS, NO NEW LOADS.  4677 SQFT.  WORK TO BE PERFORMED IN SUITE 1030.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48348	09041-10006-24226	13488 W MAXELLA AVE	90292		105B153    77	4212004014	[Q]M1-1, [T][Q]RAS4-1		Palms - Mar Vista - Del Rey	Del Rey			Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM			PC Approved	11/05/2012 12:00:00 AM	ADDRESS	33.98592	-118.44252	Delta 8 revisions to permitted set of plan: for apartment units feeders , equipment grounding conductors were increased propertionally in accordance with Section 250.122(B) OF THE NEC. CHANGES WERE CLOUDED AND IDENTIFIED ASDdELTA 8 CHANGES((((((((New 244 apartment building in methane zone.  Variance was filed to separate the the Fire Alarm plans and approval.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48349	15041-10001-10411	9246 N BALCOM AVE	91325	12	198B129   277	2766006007	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	34.23884	-118.52144	EXPEDITEDS RSES PLAN CHECK PER APPLICANT REQUEST.<<,PV1, INSTALL NEW 13.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, TIE WITH MAIN SERVICE PANEL. (40) MODULES: SUNPOWER SPR-E20-327, (2) INVERTERS:SMA SB6000TL-US-22>>.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48350	12041-10000-16114	4791 N VISTA DE ORO AVE	91364	3	169-5A111 147	2174014003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.15728	-118.58199	Plan check for new roof mounted 10.464KW Photovoltaic system (Sunpower transformerless inverters).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48351	17041-30000-04814	859 S LUCERNE AVE 1-12	90005	4	132B189  1263	4240008035		Central				2127.02	Electrical	Electrical	Apartment			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.05881	-118.326	Plan check for a fire alarm system for an existing apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (66) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48352	19041-10000-18357	15858 W GRESHAM ST	91343	12	195B141   465	2672018006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.23096	-118.47827	PC FOR PV-1 , SYSTEM INCLUDES 26 MODULES (HANWHA ) W 320 SOLAREDGE OPTIMIZERS AND 1 5000H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48353	17041-10001-31372	9939 N BABBITT AVE	91325	12	201B133    19	2694013028	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.25157	-118.5102	OFF HOUR PLAN CHECK PLAN CHECK UNDER 17041-10000-31372PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 54 AC MODULES(SUNPOWER SPR-X21-345-C-AC). SYSTEM SIZE 17.28KVA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48354	11041-10001-02482	532 S ARDEN BLVD	90020	4	135B189   760	5505020005	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2011 12:00:00 AM			Corrections Issued	05/27/2011 12:00:00 AM	ADDRESS	34.06426	-118.32561	INSTALLATION OF 13.43KW PHOTOVOLTAIC SYSTEM ON THE ROOFS OF A SFD AND DETACHED GARAGE. PERMIT HAS BEEN OBTAINED ON 10041-10000-23405((((( supplemental plan check for change of location of diconnect, invertor and conduit routing.)))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48355	10041-10000-01352	103 E 21ST ST	90011	9	121-5A207  16	5127025012	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM			Corrections Issued	02/04/2010 12:00:00 AM	ADDRESS	34.02899	-118.26577	TI in an existing 3 story building. Existing Service & Panels. Complete Rewire of the building. Applicant & Inspector are requesting plan check.  EPC is for Power, Energy & Emergency Lights.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48356	14041-20000-01107	7301 N QUARTZ AVE	91306	3	186B117   864	2115010018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.20309	-118.56466	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48357	13041-20001-09523	1794 W 36TH ST	90018	8	120B193  1244	5041014001	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	09/18/2013 12:00:00 AM	ADDRESS	34.02271	-118.31167	((7/10/2013: CHANGES MADE TO APPROVED SET OF PLANS. CHANGES MODULE MANUFACTURER AND ADDED 2 ADDITIONAL MODULES.))PV1 MICROINVERTER STANDARD PLAN. ROOF MOUNTED. SYSTEM SIZE IS 4KW. ENPHASE MICROINVERTER WITH TRINA SOLAR 240.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48358	17041-10000-19227	19736 W DEARBORN ST	91311	12	198B117   190	2761001088	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.23711	-118.56369	PC for T24 for outdoor lighting replacing 9 HID units for new LED lights. Total of 32725 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48359	16041-10003-32128	14566 W VENTURA BLVD	91403	4	166-5A151 122	2276001015	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.15112	-118.45096	T-24, PC FOR ENERGY ONLY. TI AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR RETAIL AND RESTROOM SPACE. TOTAL AFFECTED AREA IS 1618 SQ. FT. NOTE: PERMIT IS PAID UNDER PCIS#16016-10002-32128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48360	13041-10000-15696	1315 W 7TH ST	90017	1	130-5A205  94	5143013034	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			06/14/2013 12:00:00 AM			Corrections Issued	06/14/2013 12:00:00 AM	ADDRESS	34.05267	-118.26802	PLAN CHECK T24 ENERGY/EMERGENCY FOR EXISTING APARTMENT BUILDING PARKING GARAGES, CORRIDORS, AND COMMON AREAS. ALL WIRING ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48361	14041-20001-28727	4568 N NAGLE AVE	91423	4	168B157   838	2360020036	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			PC Approved	10/29/2014 12:00:00 AM	ADDRESS	34.15367	-118.42352	Expedited plan check fee per applicant request.  PV1.  Install 7.28 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48362	17041-20000-31585	20631 W GRESHAM ST	91306	3	195B109   104	2780009005	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.23071	-118.58299	PV1.  Install 7.15 kW roof mounted grid tied PV system.  Install 27 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48363	15041-20001-35557	14006 W RIVERSIDE DR SPACE 206	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	12/10/15Changes to an approved set. Scope includes adding/relocating receptacles/displays and adding new loads.  (((PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO NYX RETAIL AT WESTFIELD FASHION SQUARE. 1260 SQFT. SPACE #206)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48364	14041-10001-02648	3510 W GARDEN AVE	90039	13	154-5A207 347	5437007006	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.11673	-118.26051	Expedited RSES plan check per applicant request.{{PV1, Install 2.75 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel.(1) Transformerless inverter: POWER-ONE AURORA  PVI-3.0-OUTD-S-US. (11) Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48365	17041-10001-04826	2558 W SAN FERNANDO ROAD	90065	1	150B213   451	5457002013	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM			PC Approved	03/17/2017 12:00:00 AM	ADDRESS	34.10789	-118.24149	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 9kW with 27 modules and 1 inverter(9.0kW 3 phase) connected to 200A Panel.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48366	16041-10001-06677	9262 W NIGHTINGALE DR	90069	4	150B169  1376	5561007024	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2019 12:00:00 AM			PC Info Complete	02/21/2019 12:00:00 AM	ADDRESS	34.10344	-118.39091	CHANGES TO APPROVED SET OF PLANS -  RELOCATION OF LOADS AND LIGHTING SYSTEM, ADDITION OF NEW EQUIPMENT AND RECALCULATION OF LOADS. - ALL CHANGES HAVE BEEN CLOUDED UNDER DELTA 4. PLAN CHECK ONLY. ELECTRICAL PERMIT PULLED UNDER BUILDING APPLICATION: 15010-10000-03203	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48367	15041-10000-41136	10623 W VENICE BLVD	90034	5	117B161   250	4314001054	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.01927	-118.40695	Energy plan check for a restaurant (McDonald's) T.I. Scope includes new lighting and receptacles. Total area 4084-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48368	18041-10000-02271	1201 S HOPE ST	90015	14	126A207    67	5138026036	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	34.0408	-118.26471	PC for new FA system for 35 and 42 story builing(s) (Building composed of two towers that share the same parking structure). Installing 7 FACP's, 43 RPS and 3775 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48369	15041-20000-35852	300 S GRAND AVE 24th Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	05/02/2016 12:00:00 AM		Issued	05/02/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for energy only. TI to office in high rise office building on 24th floor. New lighting (incl. emergency) and receptacles. 12,235sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48370	18041-20000-18899	11246 W OTSEGO ST	91601	2	171B173   913	2353013003	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.16279	-118.37612	New 70-unit 6-story apartment building with 2 levels subterranean garage.  2000A 208Y/120V 3ph-4w service.Building permit filed under 16010-20000-06204	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48371	14041-20000-02140	2423 W LOY LANE	90041	14	162A221   152	5682023003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.13827	-118.21984	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48372	19041-10000-38438	6956 W 85TH ST	90045	11	096B161   460	4112002033	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Expired	03/20/2024 12:00:00 AM	ADDRESS	33.96109	-118.41265	[E-Plan] 0$ final fees per AB1414Changes to approved set, Changes include upgrande of New 225A Main Service Panel 2 Gang Meter. Changes have been clouded under delta F	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48373	13041-10000-30931	911 N ALFRED ST	90069	5	144B173   348	5529006074	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Verifications in Progress	12/18/2013 12:00:00 AM	ADDRESS	34.08737	-118.37541	PV1, Install 8.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US. 44 modules HANWHA # HSL60P6-PB-4-250TW..	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48374	17041-10000-17414	405 S MATEO ST	90013	14	127-5A217  62	5163018006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.04184	-118.23305	PC for new fire alarm system for 5 story building. PC for 119 devices, 1 FACP, 1annunciator panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48375	13041-10000-05024	1800 N CAMINO PALMERO	90046	4	150B181   697	5572029013	RE9-1	Central	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2013 12:00:00 AM	03/04/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.10368	-118.35012	PV1 SINGLE STORY ONE STORY HOME. TOTAL SYSTEM SIZE: 9.870 KW. TOTAL NUMBER OF MODELS: 42. [INVERTER: SUNNY BOY 8000-US-240] [SOLAR MODULE: ALEO. MODEL#: S79U235]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48376	17041-20000-38029	1584 E MARTIN LUTHER KING, JR BLVD	90011	9	115-5A213 203	5117012901	OS-1XL	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.01044	-118.24682	Plan check for fire alarm system. New fire alarm system for classroom buildings. 1 FACP. 36 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48377	10041-20000-12478	22932 W OXNARD ST	91367	3	177B097   518	2041020013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2010 12:00:00 AM			PC Approved	07/07/2010 12:00:00 AM	ADDRESS	34.17905	-118.62657	19KW PV SYSTEM FOR SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48378	12041-20000-01333	5955 N LINDLEY AVE	91356	3	177B125   762	2157013144	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.17874	-118.52748	PHASE 2 electrical work for St. Mary's Assyrian Church of the East.  Install lighting and branch circuits.  Plan check for power and energy.  Note: PHASE 1 approved under 10041-20000-18927	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48379	18041-20004-13383	6180 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	ADDRESS	34.18261	-118.39631	Revisions to approved set.  Addition of  equipment, outlets, miscellaneous power and lighting changes. clouded changes only  Associated building permits under 16010-10000-05907/05917/05918/05919/05920.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48380	11041-20000-04197	7166 W MELROSE AVE	90036	5	141B181   636	5525015003	C2-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	03/16/2011 12:00:00 AM	PIN	34.083207	-118.34574992	PLAN CHECK T24 ENERGY/EMERGENCY FOR EXTERIOR AND INTERIOR IMPROVEMENT TO EXISTING RESTAURANT. NEW LIGHTING ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48381	14041-20000-31500	814-830 E TRACTION AVE	90013	14	127-5A215 107	5163013006	(T)(Q)CM-1, M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.04489	-118.23562	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO PUB. BUILDING SUBMITTED PRIOR TO JULY1. BUILDING P# 14016-10000-03068: CHANGE OF USE FROM MANUFACTURING TO NEW BREW  PUB AND RESTAURANT IN GROUND FLOOR AND BASEMENT LEVELS OF EXISTING 3-STORY (+ BASEMENT) BUILDING PER  ZA CASE 2012-1655 (CUB)(ZV).   CREATE   OUTDOOR  EATING  AREA  73'  X  16.8'.   CONVERT  PORTION  OF  BASEMENT  STOGE  TO  MANUFACTURING.    add   outdoor  eating  canopy  irregular 16'  x   82.5'.  Connect brewery  equipment to  the  sturctural  slab   per  structural  details.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48382	16041-20001-10972	11332 W OSBORNE ST	91342	7	213B173   404	2530022005	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.27704	-118.37784	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17.11 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48383	15041-10000-43185	1127 W 187TH PL	90248	15	060B197   410	6109015024	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Expired	01/25/2018 12:00:00 AM	ADDRESS	33.86065	-118.2934	PV1, SOLAR ROOF MOUNTED SYSTEM WITH CENTRAL INVERTERS. (31) MODULES (1) INVERTER-6KW-AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48384	18041-20000-48552	21600 W OXNARD ST Suite 1755	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 only. Project site is a tenant suite in an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,266 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48385	13041-20000-26134	19565 W PARTHENIA ST	91324	12	195B117   172	2783025101	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.22837	-118.56015	T24 FOR REMODEL OF EXISTING SPACE. CONVERTING STORAGE SPACE TO HALF OFFICE HALF STORAGE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48386	15041-10000-07103	3020 W RIVERSIDE DR	90039	4	153A207   317	5434024026	CM-1VL-RIO	Central	Hollywood	Silver Lake	YES	1882.01	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.11155	-118.2669	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 4088 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48387	16041-10000-45090	697 S WITMER ST	90017	1	130-5A205 108	5143013022	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			01/11/2017 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.05267	-118.26754	PC FOR POWER AND ENERGY. NEW 6-STORY, 76 UNITS APARTMENT BUILDING. SERVICE > 1200 AB # 16010-10000-05931	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48388	10041-10000-05800	5700 W WILSHIRE BLVD #452	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	34.06218	-118.35303	T.I. for a high rise building of 4th floor.  Install general and emergency lighting in showroom area.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48389	10041-10000-03365	510 W 6TH ST # 104	90014	9	129A209   101	5144004037	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	07/09/2010 12:00:00 AM	ADDRESS	34.0482	-118.25464	T.I.   REMODEL OF EXISTING  RETAIL,  SPACE INCLUDING DOORS,  PARTITIONS,  FIXTURES,   862  SQ.FT.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48390	10041-10000-01728	2100 E PACIFIC COAST HWY FCCU	90744	15	033B213    10	7428007003	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	33.79122	-118.23692	INSTALLATION OF A STATE OF CALIFORNIA PERMITTED PRE-MANUFACTURED BUILDING TO FUNCTION AS AN EMPLOYEE OFFICE FOR THE TESORO REFINERY, AND NEW CANOPY AND A STORAGE SHED.   <<<<<>>>>> FCCU AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48391	12041-10000-03389	2509 S ROBERTSON BLVD	90034	5	126B169  1228	4302013005	[Q]C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	ADDRESS	34.0388	-118.38847	T.I. to an existing retail store, no suite number per applicant - stand-alone building.  Change to lighting.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48392	15041-10000-21961	8436 W 3RD ST	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Closed	02/12/2024 12:00:00 AM	ADDRESS	34.07301	-118.37448	PC FOR POWER AND ENERGY. REMODELING OF COMMON AREA OF AN MEDICAL BUIDING. TOTAL AREA 6537 SQ FT.  WORK ON 1ST, 6TH, 7TH, 8TH, AND 9TH FLOOR COMMON AREAS AND FACADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48393	14041-20000-08869	19600 W WELLS DR	91356	3	171B117   372	2175011004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM			Corrections Issued	04/03/2014 12:00:00 AM	ADDRESS	34.16395	-118.56074	PV1 10.53KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(2) inverters: {SOLAREDGE SE3800A-US, SOLAREDGE SE6000A-US}]. [(39)modules: {solarworld SunModule SW-275 mono}] with optimizers: [SOLAREDGE {POWERBOX 300W }]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48394	14041-20000-11526	12022 N ELNORA PL	91344	12	216B133   243	2606010028	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.28947	-118.50912	PV1Install roof-mounted solar array (4 strings) on SFD. Service size: 7.79kW(2) SMA  America SB3800TL-US-22  transformerless inverters(36) ET Solar ET-P660250BB pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48395	19041-20001-27709	4335 W CEDARHURST CIR	90027	4	150B201    80	5591007007	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM			PC Approved	09/06/2019 12:00:00 AM	ADDRESS	34.11121	-118.28435	09-06-2019 Changes to an approved set of plan, Changes include addition of PV meter and disconnecting means, and disconnect for Tesla Battery. All changes has been clouded. Plan check only, permit fee covered onder master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48396	12041-10000-08891	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	ADDRESS	34.01303	-118.24279	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT; 1ST & 2ND FLOOR OFFICE SPACES RENOVATION; RENOVATION AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48397	13041-10000-06899	11058 W SANTA MONICA BLVD	90025	5	129B153   827	4323020025	C2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM			PC Approved	03/18/2013 12:00:00 AM	ADDRESS	34.04769	-118.44324	T.I. WORK TO JOIN TWO (E) RESTAURANTS INTO (1) CREATE 2 (N) OPENINGS AND UPGRADE RESTROOMS.  (N) WALK-IN FREEZERS AND DINING AREA PLAN .CHECK IS FOR TITLE 24 . PERMIT IS OBTAINED AT ELECTRICAL COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48398	17041-20000-01582	7780 W TORREYSON DR	90046	4	159B173   643	5570014010	RE40-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.12857	-118.36833	permit fee $0.00 by state senate bill no. 1222pv1install roof monted pv system sized 14kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48399	13041-10000-35430	16601 W RINALDI ST BLDG B	91344	12	213B137   476	2610014008	A1-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	12/19/2016 12:00:00 AM		Issued	12/19/2016 12:00:00 AM	ADDRESS	34.27948	-118.49358	"FULL PLAN CHECK FOR POWER AND ENERGY TO NEW COMMERCIAL BUILDING. CONSTRUCTION OF 3 STORY  BUILDINGS(GYMNASIUM + CLASSROOM). THIS IS DESIGNATED AS BUILDING ""B"" ON THE PLAN. PLAN CHECKER PLEASE CHECK THE FEES FOR 3 BUILDING A,B AND C.BUILDING PERMIT: 13010-10000-04216"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48400	12041-10000-12954	19780 S PACIFIC GATEWAY DR	90502	15	057B197    48	7351034069	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	33.85141	-118.29512	Split 800A service into two 400A meters. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48401	11041-20000-12448	18040 W SHERMAN WAY 5th Floor	91335	3	183B125   226	2121023042	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			Corrections Issued	06/16/2011 12:00:00 AM	ADDRESS	34.20091	-118.52659	T.I. to existing high rise building.  Install general/emergency lighting on the 5th floor of the everest college.  Plan check for energy only.Note: Permit under 11041-20000-12449	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48402	16041-30000-38144	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	02/05/2018 12:00:00 AM		Issued	02/05/2018 12:00:00 AM	ADDRESS	34.26153	-118.50259	Permit fee is $0.00 due to Senate Bill 1222.Installation of new roof mounted solar PV array on existing commercial medical office.  System is connected directly to utility: feed-in-tarrif.  Total system size = 366.3 kWAC, (1114) modules, (557) optimizers, and (11) 33.3kw inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48403	15041-20000-05506	549 S OLIVE ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM			PC Approved	04/06/2015 12:00:00 AM	ADDRESS	34.04832	-118.25415	Plan check for Title 24 only. Project space is an existing tenant space within a high-rise building. Total lighting area = 1,425 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48404	19041-10000-20982	5536 N VINELAND AVE	91601	2	174B173  1111	2416001046	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Issued	06/04/2019 12:00:00 AM	ADDRESS	34.1712	-118.37009	Remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor)- T24 Only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48405	11041-20000-03664	8635 W 3RD ST #1190W	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.07373	-118.38073	T.I. to suite #1190W to high rise Cedar Sinai medical building.  Plan check for power and energy. No new ckts added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48406	18041-10003-22421	16127 W DEARBORN ST	91343	12	198B141   552	2671020010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.23761	-118.48366	Plan check only. R5 changes to approved set per inspector request to show all meter sockets location on the plans. Previous scope: CHANGES TO APPROVED SET TO UPDATE WORK DISCRIPTION SYSTEM AC VALUE TO 10KWAC WITH 11.39 KWAC(CEC) AS SHOWN ON THE PLANS AND CUTSHEETS. CHANGES ALSO INCLUDE THE INSTALLATION OF DWP PEODUCTION METER FOR A SYSTEM WITH CEC VALUE GREATER THAN 10KWACPrevious Scope: SUPPLEMENTAL FOR CHANGES TO APPROVED SET - PANEL UPGRADE FROM 200A CENTER FEED TO 225A PV END FEED. CHANGES ARE NOTED UNDER R2PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 11.685KWDC /10.95KWACSCOPE INCLUDES 41 MODULES WITH OPTIMZERS AND CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48407	18041-10000-02084	11961 W SANTA MONICA BLVD	90025	11	126B145   518	4263029052	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.04143	-118.46194	PLAN CHECK ONLY CHANGE OF USE FROM A RETAIL STORE TO A BEAUTY SALONPLAN CHECK IS FOR TITLE 24 AND 1 MERGENCY CKT ONLYELECTRICAL PERMIT WAS OBTAINED ON APPLICATION 17041-30000-42945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48408	13041-10013-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	MODIFYIING LIGHTING SYSYTEM IN AREA  THAT IS  PART OF ORIGINAL PERMIT ISSUEDPLAN CHK IS FOR CHANGES IN THE FIELD DURING CONTRUCTION((((((((((Replacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48409	16041-20000-31983	2066 N HILLHURST AVE	90027	4	150B201   343	5590008003	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.10948	-118.28726	Plan check for energy only. Change of use from retail to coffee shop + restrooms. New indoor (incl. emergency) and outdoor lighting. T24 - indoor area: 1,030sqft; outdoor area: 283sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48410	19041-20000-23191	20101 W WELLS DR	91364	3	171B113   408	2166009003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.16259	-118.57055	addition of (2) tesla ESS rested 5KW each to an existing pv sysetm.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48411	18041-20001-48686	864 S ROBERTSON BLVD 2nd floor	90035	5	132B169   100	4333015025	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.06106	-118.38339	REVISION FOR AN APPROVED SET T-24 ONLY.  REMOVING CONTROLLED REC IN OFFICES. DELTA AREV ONLY.ORIGINAL PC # 18041-20000-48686	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48412	13041-10000-36109	8532 N THUNDERBIRD DR	91343	6	192B145   727	2654020***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.22559	-118.46904	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(18)modules: {Renesola {JC250M-24/BB}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48413	11041-20000-22305	7703 N DENSMORE AVE	91406	6	189B141   270	2206010006	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	05/29/2012 12:00:00 AM	ADDRESS	34.21059	-118.47725	PLAN CHECK POWER AND ENERGY FOR NEW 600A SERVICE SERVING EXISTING BUILDING. NEW CKTS IN NEW PANELS AND EXISTING CKTS IN NEW PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48414	14041-20000-34866	7509 N WOODLEY AVE	91406	6	186B141   265	2205022002	[T][Q]MR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.20687	-118.48387	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(18) SOLAR WORLD SW 270 MODULES(18) ENPHASE M-215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48415	17041-20001-22160	22330 W MAYALL ST	91311	12	204B101   433	2745011046	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	07/12/2017 12:00:00 AM	ADDRESS	34.25388	-118.61379	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system, SFD.10.4kW ungrounded system. (38) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48416	14041-20000-35638	3800 S WESTERN AVE	90062	8	117B193   782	5036008006	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Closed	02/28/2017 12:00:00 AM	ADDRESS	34.01723	-118.30873	"""0$ permit fees due to senate bill 1222 ""PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 37.5KW INTERCONNECTED WITH MSP.(152) QCELL Q.PRO-G3 260W MODULES(4) FRONIUS UNI INVERTERS"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48417	12041-10000-10811	11019 W PENROSE ST	91352	6	195B173   312	2408027024	[T][Q]M1-1, [T][Q]P-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM			PC Info Complete	05/10/2012 12:00:00 AM	ADDRESS	34.2296	-118.37117	per owners request , plan check, addition of a xfrmr, and addition of kitchen equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48418	18041-10001-01026	717 S MORENO AVE	90049	11	126B141   235	4264007051	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	34.04281	-118.48391	PC for DELTA 1 changes to an approved set. Replacing permitted 2 LG RESU10 batteries with new compatable Sonnen eco12 batttery.  Inspector to verify UNIT LISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48419	14041-10000-06579	1234 W 7TH ST	90017	1	130-5A207 158	5143009003	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.05185	-118.26696	"PLANCHECK FOR POWER AND ENERGY. New 1200 AMPS service. Place of assembly. CHANGE OF USE FROM PRINTING SHOP TO: 1) DANCE HALL W/ STAGE AND A 'BAr and restaurant.Changes on plans: ""Shall have an equipment grounding conductor according to 250.118 or shall contain an insulated equipment grounding conductor sized in accordance with Table 250.122.""Bldg#13016-10-21682"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48420	14041-20001-24264	10464 W PENROSE ST	91352	7	195B177   241	2404003006	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.2321	-118.35954	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.8kW.(1) Power-One PVI-4.2-OUTD-S-US-A transformerless inverter(1) Power-One PVI-3.6-OUTD-S-US-A transformerless inverter(39) REC Solar REC260PE(BLK) pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48421	16041-10000-38001	4061-4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.99055	-118.44379	PC FOR POWER AND ENERGY FOR A MIXED USED BUILDING (49 UNITS)SCOPE INCLUDES NEW SERVICE (4000A /480V)B#16010-10000-04167	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48422	17041-10000-06615	3501 N EAGLE ROCK BLVD	90065	13	154-5A215 262	5457026011	[Q]CM-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.02	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.11604	-118.23591	PC FOR POWER .UPGRADING SERVICE TO 800A 120/240 3 PHASE 4W. COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48423	19041-20000-13020	7858 S BLERIOT AVE	90045	11	099B169   680	4106024029	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	33.96746	-118.3911	Plan check for PV roof mounted system, system size: 5.04KW with 14 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48424	18041-10000-22145	7880 N VAN NUYS BLVD 1-7	91402	6	189B149   638	2212028014	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.21541	-118.4462	T.I. IN AN EXISTING RETAIL STORE. T-24 ENERGY ONLY (9,528sqft)BUILDING PERMIT: 18016-10000-18967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48425	13041-10000-36039	11362 W DONA TERESA DR	91604	2	159B169   657	2381010009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.1293	-118.38081	PV1, Install 5 kW DC roof-mounted solar array for a two story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (20) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48426	16041-10000-27264	5510 S LINCOLN BLVD STE 420	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	33.97299	-118.43051	Tenant improvement. PC for title 24 to a commercial office building. Installing new lighting and power only. Total sqft = 3249.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48427	19041-20000-26397	7327 N KESTER AVE Bldg.B#4-6	91405	6	186B149   653	2221014008	RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.20387	-118.45764	plan check for new 3-story 3-unit townhouse with attached garage, building B. scope of work includes 3 125A panels and T24, total square footage = 2605 sfService installed on Building A.UNDER B#16010-20000-01946 UNIT B 4-6Second elec permit for building A under: 19041-20000-23307	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48428	19041-10000-01859	8826 N BRADLEY AVE	91352	6	195B173   315	2408025051	[T][Q]M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Issued	06/19/2019 12:00:00 AM	ADDRESS	34.22969	-118.37566	"FULL PLAN CHECK FOR TENANT IMPROVEMENTS & CHANGE 4,790 SF OF USE TO NURSERY/HYPROPONTIC AGRICULTURAL ENTERPRISE."" SCOPE OF WORK INCLUDES NEW LOAD, LIGHTING AND POWER. EXISTING SERVICE 800A, 120/240,3PH, 4W. TOTAL SQ. FT. 5268."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48429	15041-20001-32290	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	34.24253	-118.57768	** Changed to an approved set, adding lights to (E)(5) offices and (E)(2) conference rooms.New Total area: 8,186 sq.ft. Permit under the Master plan 15041-20000-32290	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48430	19041-20000-13274	315 S THURSTON AVE	90049	5	135B145    64	4366015021	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.06998	-118.4629	INSTALLATION OF (2) 5KW TESLA POWERWALL BATTERIES, A 200A EMERGENCY PANEL, AND (2) 125A SUB PANELS TO A EXISTING SFD WITH A EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48431	16041-10000-33533	1014 E MANCHESTER AVE	90001	9	097-5A209 264	6042023030	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	33.96	-118.25717	Plan check for power and energy for change of use from retail to Dental Office and exam rooms.  Total area: 2245 sq ft.   (B# 16016-10000-18516)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48432	12041-10000-27538	21340 W STANWELL ST	91311	12	207B105   478	2706028033	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.26208	-118.59677	PV1 11.52KW ROOF-MOUNT FRONIUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48433	14041-20001-18023	12196 W VENTURA BLVD	91604	2	162B165   214	2369004039	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			PC Approved	09/12/2014 12:00:00 AM	ADDRESS	34.14305	-118.39841	Inspector requested re-stamp. Change plans to show 22,000A available fault current and include DWP report on plans. Add note that new panel and all new breakers shall be rated for 22kAIC.[[[Title 24 plan check only.  Total area = 555 sq. ft.Kitchen remodeling for existing restaraunt space.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48434	12041-10001-13257	6129 E DELPHI ST PV1	90042	14	157-5A231 351	5486005002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	ADDRESS	34.12449	-118.18646	PLAN CHECK FOR 2.4KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING SOLAREDGE TRANSFORMERLESS INVERTER AND DC-DC POWER BOX. EXISTING PERMIT. ZONING CLEARANCE APPROVAL WAS ISSUED UNDER 12041-10000-13257.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48435	14041-20000-01684	1307 S ALVARADO ST	90006	1	129A201   232	5135001020	C2-1	Central	Westlake	Pico Union		2243.10	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			Reviewed by Supervisor	01/31/2014 12:00:00 AM	ADDRESS	34.04694	-118.28311	new service to existing market	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48436	14041-10000-20552	11620 W WILSHIRE BLVD #1150	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT.  OFFICES. 6000SQFT, EMERGENCY LIGHTING. 11TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48437	16041-30000-13090	1937 S PONTIUS AVE	90025	5	126B153   395	4323025024	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			PC Approved	04/29/2016 12:00:00 AM	ADDRESS	34.04323	-118.44144	Plan check for T.I. Title 24 energy only in existing space. Total area: 370 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48438	17041-10001-02880	13643 W MUSCATINE ST	91331	6	195B157  1199	2637007028	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.22682	-118.42955	02/02/2017 Changes to an approved set of plan. Changes include change main panel from 100 A to 200A. Changes has been clouded.  ((((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(1)INVERTER-SE3800A-US(12)MODULES-VBHN325SA16(12)OPTIIMIZERS-SOLAREDGE P400))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48439	19041-10000-15278	4960 E HUNTINGTON DR SOUTH	90032	14	144A235   333	5218009020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	05/29/2021 12:00:00 AM	ADDRESS	34.08745	-118.17453	PC PWR FOR SHELL TI. SCOPE INCLUDE NEW 1200A, 208/120V, 3PH, 4W SERVICE AND HVAC EQUIPMENT. AREA OF SCOPE IS APPROX 10,652SF.B PERMIT# 18016-10K-18409	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48440	14041-20000-24979	12231 W BRANFORD ST	91331	7	204B165   369	2537015059	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Expired	12/02/2016 12:00:00 AM	PIN	34.25166888	-118.40038778	Plan check for power only. New 1600 amp service and new standup section only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48441	19041-20000-24025	1417 N GLENDALE BLVD	90026	13	141A209   273	5419019017	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1956.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM			PC Info Complete	06/21/2019 12:00:00 AM	ADDRESS	34.08055	-118.26039	T24 PLAN CHECK FOR TI WORK IN EXISTING MCDONALDS. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2390 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48442	19041-10000-04594	611 W WILSHIRE BLVD	90017	14	129A209    82	5144005021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	11/08/2020 12:00:00 AM	ADDRESS	34.04838	-118.25639	REPLACING TWO EXISTING DEFECTIVE 125KVA UPS WITH TWO NEW UPS's AT THE SAME LOCATION LIKE TO LIKE. NO NEW LOADS WERE ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48443	16041-40000-03672	2029 S CENTURY PARK EAST SUITE 950	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, TI TO AN (E) OFFICE SPACE IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3850.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48444	16041-10002-19283	8101 W MELROSE AVE	90046	5	141B177   568	5528007014	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	ADDRESS	34.08389	-118.36609	PLANS ARE REVISED TO INDICATE WORK TO BE DONE UNDER ORIGINAL PERMIT; WIRING TO TENANT SPACES WERE NOT TO BE DONE UNDER ORIGINAL PERMIT. THE SCOPE OF WORK IS FOR CORE AND SHELL  POWER SUPPLY TO THE BUILDING. EACH TENANT WILL DEVEL0PE HIS  OWN SPACE ((((((((COMPLETE REWIRE OF EXISTING BUILDING REMODEL. PER BUILDING, PC IN ACCORDANCE TO 2008 ENERGY CODE. NEW SERVICE AND DISTRIBUTION THROUGHOUT. NEW LIGHTING AND POWER. PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48445	14041-10000-04003	3441 S MCCLINTOCK AVE	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.02421	-118.28812	"INSTALLATION OF NEW LED SCOREBOARD TO UPPER (2) FLOORS OF AQUATICS CENTER BUILDING (51'-2"" X 11'-6"") EPC IS FOR T24."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48446	12041-20000-23161	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.06188	-118.30486	New fire alarm system for 3 story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48447	15041-10000-23928	12055 W BURBANK BLVD	91607	2	174B165   742	2340028065	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.17231	-118.396	INSTALLATION OF A FIRE ALARM SYSTEM. SINGLE STORY BULDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48448	18041-20000-35981	3809 S GRAND VIEW BLVD	90066	11	114B157  1475	4235023001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	34.00441	-118.43106	Plan check for Title 24 only. Project site is an existing restaurant. Project scope is an expansion and tenant improvement. Total lighting area = 1,509 sq. ft.Note: Building application has been generated under 18016-10000-26894	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48449	12041-20000-06095			11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM			PC Approved	03/16/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	Revisions to 11041-10000-14514Change to routing of new feeder to existing Guard Post panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48450	17041-20000-38315	1420 N COIL AVE	90744	15	036B213    16	7426029007	[Q]MR2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.79347	-118.24241	Replacement of existing luminaires for cooler and freezer docking areas in commercial structure.  Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48451	14041-10002-23513	1124-1132 S SAN JULIAN ST	90015	14	124-5A211 205	5145025002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM			PC Approved	12/04/2014 12:00:00 AM	ADDRESS	34.03521	-118.25351	This supplemental permit is to reference , both permit  # 14041-10000-23513 and 23523 are approved by M.Zandi at ladbs. and are located in methane buffer zone according to Bldg permit number13016-10000-25985.PLANCHECK FOR POWER AND ENERGY FOR BLDG 16.PLANCHECKER TO ADJUST FEES FOR BLDG 16 AND 17.[[[13016-10000-25985 bldg 16]  RENOVATE (E) 3-STORY PRODUCE WHOLESALE BLDG TO REMOVE ALL INTERIOR STRUCTURES, REPLACE WINDOWS/DOORS, BUILD  NEW RAMPS, STAIRS,RESTROOMS, ELEVATOR (EXISTING PIT), LONG TERM BIKE PKG ROOM, NEW ROOFING/INSULATION AND NEW CONCRETE WALLS FOR STAIR AND ELEVATOR SHAFTS.  SEE COMMENT.]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48452	17041-20000-12374	3121 W OLYMPIC BLVD 101A-102	90006	10	129B193   271	5080024027	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Info Complete	04/17/2017 12:00:00 AM	ADDRESS	34.05277	-118.30387	"PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM RETAIL TO BANK. "" CBB BANK"" 2777 SQFT. UNIT 101A AND UNIT 102"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48453	17041-10001-15545	600 S LA BREA AVE	90036	4	135B181   610	5507023031	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Info Complete	06/25/2018 12:00:00 AM	ADDRESS	34.06474	-118.34381	"Changes to an approved set of plans. All changes are clouded under delta 3. Changes include relocating panel ""P3"" to be refed from Panel ""HP"" on the single line diagram.Note: Permit is paid under master application 17041-10000-15545"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48454	14041-10001-35138	717 N HIGHLAND AVE	90038	5	141B185  1187	5524012***	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	34.0842	-118.33898	EXPEITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 2.805 KW DC ROOF-MOUNTED SOLAR ARRAY ON 3-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(11) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48455	18041-10000-01362	710 S SANTA FE AVE Front-House	90021	14	124-5A217 285	5166002018	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	ADDRESS	34.03414	-118.22981	Full plan check for a two story building, change of use from Studio to a restaurant and (9) hotel  room. Note this is one of the two the application with the same plan under same address.  Bld: 17016-10000-25792	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48456	19041-20000-34182	20613 W BLUEBIRD CT	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.29714	-118.58277	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48457	07041-10003-20545	366 W 8TH ST Unit 1-Unit 18	90731	15	015B201   249	7455011023	C2-2	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Apartment			09/15/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	33.73704	-118.28519	DELTA 2 & DELTA 3 CHANGES TO THE APPROVED PLANS.  *. Changing underground service to overhead and changing the configuration of service.   Elevator motor changed from 7.5HP to 15HP. Garage exhaust fan changed from 5HP to 7.5HP. House panel changed from 200A to 400Amp.  MS changed from 1000A to 1200A.New 18 units condo.  with 8 typicals.  New 1000amp, 120/240, 1ph service.  Plan check for power and energy.  File variance for fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48458	10041-10000-23896	12160 W VICTORY BLVD	91606	2	180B165   754	2334001069	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1238.00	Electrical	Electrical	Public Safety Only			12/01/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	ADDRESS	34.18651	-118.39837	NEW FIRE WARNING SYSTEM IN AN EXISTING  9-STORIES BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48459	13041-20001-31884	12837 N SEAGLASS	90094										Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM				((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48460	19041-10000-39724	2137 N BANYAN DR	90049	11	138B133   278	4492010015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.07468	-118.50253	[EPLAN] PLAN CHECK FOR 3 ESS(TESLA POWERWALL) CONNECTED TO EXISTING PV1 SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48461	13041-10000-15004	4623 N EAGLE ROCK BLVD	90041	14	159A221   400	5473038005		East Los Angeles				1834.02	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.12813	-118.21786	"PC FOR ENERGY ONLY. MEDICAL OFFICE. standalone building per applicant.CHANGE OF USE FROM (E) OFFICE TO MEDICAL OFFICE. WORK INCLUDES NEW INTERIOR NON-BEARING PARTITIONS, SUSPENDED CEILING, MILLWORK. RESTRIPE PARKING LAYOUT WITH NEW  TRASH ENCLOSURE. SEE COMMENT. **""COMPLY WITH DEPARTMENT ORDER effective date 05/15/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""**"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48462	14041-20000-15422	6700 W DAY ST	91042	7	204B201   923	2570006021	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.25323	-118.27842	PV1Install roof-mounted solar array on SFD. System size: 3.8kW(1) SMA SB3800TL-US transformerless inverter(16) LG 270W pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48463	18041-10000-43951	2971 N PARTRIDGE AVE	90039	13	150B213   572	5442029020	OS-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.10652	-118.24544	PLAN CHECK FOR TITEL 24 ONLY FOR REPLACEMENT OF EXISTING HID FIXTURE WITH NEW LED FIXTURE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48464	10041-10000-22273	1201 E PLAZA DEL SOL	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.049	-118.22708	Solar voltaic system installed on the roof of the building.  Consists of 7 modules, 7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48465	11041-10000-21482	504 S HARBOR BLVD	90731	15	015B201   221	7440030***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			Reviewed by Supervisor	01/25/2012 12:00:00 AM	ADDRESS	33.74047	-118.27853	PLAN CHECK POWER, ENERGY, FIRE ALARM SYSTEM FOR NEW MUSEUM BLDG AT THE PORT OF LOS ANGELES. NO PLAN CHECK ON LOW VOLTAGE SECURITY AND CABLE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48466	12041-20000-17561	4322 N AGNES AVE	91604	2	165B165   577	2368013030	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.1493	-118.39523	PV system on roof of single family dwelling using enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48467	06041-10008-03444	10844-10852 W LINDBROOK DR	90024	5	132B153   242	4360003015	C4-2D-O	West Los Angeles	Westwood			2652.02	Electrical	Electrical	Apartment			08/30/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.06013	-118.44228	08/30/16Changes to an approved set of plans. All changes are clouded under delta XX. Changes include removing generator feeding emergency lights/exits, and using unit equipment for lights and exit signs.  Note: Permit is pulled under original application PCIS#06041-10000-03444(((((CHNAGES TO APPROVED SET, DELTA 33.   EMERGENCY LIGHT IS FED FROM DIFFERENT BUILDING TO FEED EXISTING BUILDING UNDER CONCTRUCTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48468	16041-10000-09375	662 S SANTA FE AVE	90021	14	124-5A217 149	5164018003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.03605	-118.23014	Service upgrade to 1600A, all loads are for future (No connected load at the moment). Scope of work includes 200A panels at address: 660 S. Santa Fe Ave.,  662 S. Santa Fe Ave.,  664 S. Santa Fe Ave.,  668 S. Santa Fe Ave	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48469	16041-10000-31791	13701 W VENTURA BLVD	91423	4	165B157   607	2271018008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM			PC Approved	09/07/2016 12:00:00 AM	ADDRESS	34.14822	-118.4314	TI FOR RESTAURANT. CHECKING FOR NEW LIGHTING T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48470	19041-10000-12599	6433 N PLATT AVE	91307	12	180B093   739	2033010039	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.18768	-118.64295	PC for Energy only. McDonald's Lighting renovation. Total affectyed area is  3767SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48471	18041-20001-08183	1636 S SAWTELLE BLVD	90025	11	129B149   480	4261008006	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM			PC Approved	03/23/2018 12:00:00 AM	ADDRESS	34.04627	-118.44804	03/23/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Electrical distribution equipment as noted has changed from single phase to three phase.*****Previous Work Description*****Plan check for power only. Project site is an existing commercial building. Project scope is the replacement of electrical distribution equipment due to a fire. Service size has remained the same. No new load has been added. Tenant panels have been replaced as noted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48472	17041-10000-44223	21300 W SUPERIOR ST	91311	12	201B105   193	2746006024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.24623	-118.59503	Plan check for T24 only, replace indoor existing fixtures with new LED fixtures, area: 7600 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48473	15041-10000-01577	8707 N BRADLEY AVE	91352	6	195B173   567	2408023022	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM			Reviewed by Supervisor	02/27/2015 12:00:00 AM	ADDRESS	34.22765	-118.37406	Consolidation of (E) electric services to (N) single 2000A service for light manufacturing building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48474	11041-10000-12754	6075 AVION WAY parking	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	07/11/2011 12:00:00 AM	PIN	33.94463112	-118.38247895	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48475	15041-10000-44011	10452 N FULLBRIGHT AVE	91311	12	207B113   242	2707017029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.26089	-118.57689	PV1, INSTALL 11550 WDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(42) MODULES:REC SOLR REC275TP(1) INVERTER: SOLAREDGE TECHNOLOGY SE 11400A-US 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48476	10041-10000-23519	801 N FAIRFAX AVE # 105	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1920.00, 1944.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	03/22/2011 12:00:00 AM	ADDRESS	34.08567	-118.36172	CHANGE OF USE FROM RETAIL TO MEAT MARKET RETAIL.( ~ 1272 S.F) PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48477	16041-10000-20410	5343 W IMPERIAL HWY	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	33.93128	-118.37337	FULL PC FOR POWER AND ENERGY FOR AN EXISTING WAREHOUSE BUILDING. SCOPE INCLUDES NEW REFRIGATION EQUIPMENT, EXAUST FANS, AND THREE NEW SUBPANELS. NEW CONNECTED LOAD IS >400A. TOTAL AFFECTED AREA IS 16151 SQ. FT.NOTE: FEES NEED TO BE VERIFIED BY PLAN CHECKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48478	17041-20000-43360	4904 S SAN PEDRO ST	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Info Complete	12/01/2017 12:00:00 AM	PIN	33.99751407	-118.26742354	INSTALLATION OF A FIRE ALARM SYSTEM. 1 FACP AND 16 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48479	14041-10000-22156	6863 N BABCOCK AVE	91605	2	183B161   771	2324027015	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Expired	11/09/2016 12:00:00 AM	ADDRESS	34.19555	-118.40746	PV1, INSTALL 9.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(37) MODULES: CANADIAN SOLAR CS6P-250PX(2) INVERTERS: SOLAREDGE SE3800A-US-ZB-U & SE5000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48480	11041-10000-17182	550 S HILL ST Ste 1560-Ste 1562	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	34.04753	-118.25268	T.I.  Remodel of office space on the 15th floor.  Converting one suite into two suites with Suite numbers 1560 and 1562.  Plan check is for energy only.  Emergency lights are existing and are to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48481	19041-10001-42101	749 S BROADWAY	90014	14	127-5A209  96	5144014028	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.04418	-118.25458	PLAN CHECK ONLY FOR TITLE 24 CHANGES ON APPROVED SET. ADDRESS DELTA 2 CHANGES. WORK INCLUDES NEW LIGHTING AND CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48482	13041-20000-00135	9307 W KIRKSIDE ROAD	90035	5	129B169   948	4306021010	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.04832	-118.39176	Plan check for PV system. PV-1. Enphase.  Friedman Residence. 200A panel upgrade has been added to inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48483	17041-10000-44711	11702 W VICTORY BLVD	91606	2	180B169  1270	2334006037	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.1865	-118.38806	PC FOR POWER AND ENERGY FOR CORE AND SHELL FOR A NEW 1-STORY W/ BASEMENT MEDICAL OFFICE BUILDING. NEW 800A SERVICE 120/208V. TOTAL CONNECTED LOAD > 400ATOTAL AFFECTED AREA 16526SQ.FT. B#17010-10000-04452	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48484	18041-10000-15489	18220 S WESTERN AVE	90248	15	063B193   242	6108001063	C1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	33.86496	-118.30893	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48485	19041-20001-06866	8700 S PERSHING DR	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Expedited plan check fee.PV2.  Install 23.04 kW DC / 20.68 kW AC roof mounted grid tied PV system.  (64) modules with (1) 20 kW rated string inverter.System 4 of 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48486	12041-10000-05130	3127 N OAKDELL LANE	91604	2	156B169   187	2382003011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.12652	-118.39041	New rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48487	13041-10001-24713	14722 W MAGNOLIA BLVD UNIT 3	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48488	16041-30000-23796	6920 S STANFORD AVE	90001	9	102B205   451	6007016015	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	33.97641	-118.26284	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 15,672 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48489	11041-10000-06114	2029 S CENTURY PARK EAST 3150	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. TO AN EXISTING HIGH-RISE OFFICE BUILDING, T-24 OVER THE COUNTER PLAN CHECK.  SUITE 3150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48490	12041-10001-06590	810 S SPRING ST	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	ADDRESS	34.04268	-118.25375	CHANGES TO  LIGHTING SYSTEM OF PERMITTED SET OF PLANS; ALSO ADDED WERE A 75KVA XFMR AND PANELBOARD  WHICH WILL SUPPLY LOADS TRANSFERED FROM OTHER PANELBOARDS((((((((((Plan check power and energy TI restaurant (Terroni Restuarant) on first floor of an high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48491	19041-20000-13430	10507 S COMPTON AVE	90002	15	090A213   132	6065016002	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	33.9403	-118.24638	PV3.  Installation of 21.9 kW DC / 19.07 kW AC CEC roof mounted grid tied PV system.  (60) modules with microinverters.$0 permit fee per State Senate Bill SB 1222 as amended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48492	12041-10000-06327	2680 N CHARL PL	90046	5	156B169   373	5565043014	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	ADDRESS	34.12071	-118.38758	PV system SFD 13.68	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48493	18041-10000-12854	505 E G ST	90744	15	030B209   310	7424010038	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	33.77896	-118.25678	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48494	17041-10000-17773	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Closed	09/08/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	Power plan check for medium voltage (5kv) equipment and all underground conduit work. This project is part of the USC Coliseum renovation project, Phase-1.Reference application: 16041-10000-42999                                          B#16016-10000-27246	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48495	16041-10000-34918	8631 W 3RD ST Suite 635	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check for power and energy. Tenant Improvement for (E) Medical Office, includes consultation area. Scope is in Suite 635 East, total affected area: 4,950 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48496	17041-10000-14871	380 WORLD WAY T50	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR ENERGY ONLY. TENANT IMPROVEMENT IN EXISITNG RETAIL SPACE, CONNECTED LOAD< 400AMP. TOTAL AREA 1531 SQ FT. B # 17016-10000-06943	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48497	17041-10001-07894	6400 S AVALON BLVD	90003	9	105B205  1049	6007018027	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Approved	05/01/2017 12:00:00 AM	ADDRESS	33.98114	-118.26497	PC FOR T24 ENERGY ONLY FOR CHANGE OUT OF LIGHTING FIXTURES. PC ONLY - PERMIT ALREADY ISSUED UNDER MASTER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48498	16041-20000-24761	14478 W VENTURA BLVD	91423	4	166-5A151 150	2266001026	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.15072	-118.44849	Plan check for Title 24 only in convenience store in 76 gas station and outdoor lighting around convenience store. Total indoor area: 1613 sq ft.  Total outdoor area: 10,521 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48499	16041-10000-44953	616 N ROSSMORE AVE	90004	4	141B185   779	5523010004	R4-2	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.08228	-118.32687	PC for energy only; Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 21,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48500	15041-10000-35388	201 N FIGUEROA ST #210	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	T-24, Ti to partial of the 2nd floor of an (E) high rise office building. Scope includes new lighting and receptacles connected to existing circuits, total sq. ft. 1065.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48501	14041-20000-26856	13360 W BEAVER ST	91342	7	225B157   235	2510024019	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.3159	-118.42384	PC FOR PV SYSTEM. TOTAL SIZE 6KW AC USING TRANSFORMERLESS INVERTER. TOTAL OF 25 MODULES. USING STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48502	11041-10000-09595	1515 W 240TH ST	90710	15	042B193   718	7439008032	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Public Safety Only			05/11/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Closed	07/19/2012 12:00:00 AM	ADDRESS	33.8074	-118.30413	new fire warning system in a commercial building- single floor with mezz	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48503	13041-10000-13579	1381 W SUNSET BLVD	90026	1	138A211    26	5406012038	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.07343	-118.25125	13041-10000-13579permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. RETAIL DOMINO'S PIZZA DELIVERY. less than 400A per applicant. 1story.CHANGE OF USE FROM RETAIL TO RESTAURANT. INTERIOR REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48504	13041-10000-27088	7900 N CASABA AVE	91306	3	189B113   739	2107025031	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.21408	-118.57667	PV1. ROOFMOUNTED 8.25 KW PHOTOVOLTAIC SYSTEM. 1 STORY HOUSE. STANDARD PLAN. (33) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48505	16041-20000-20618	5636 W FALLSGROVE ST	90016	10	117B173    36	5025005009	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.02089	-118.36832	Plan check for PV roof mounted system. System size: 5.0kW with 19 modules and 1 inverter(5.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48506	16041-10000-38975	18455 S FIGUEROA ST	90248	15	060B201    20	7339008034	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Closed	07/07/2023 12:00:00 AM	ADDRESS	33.86353	-118.28198	PC for TI;  power and energy.Scope includes new panels and additonal circuits.for title 24, total affected area is 51370 sq.ft.REF Bldg app# 16016-10000-26399	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48507	19041-10000-29785	6546 N WHITMAN AVE	91406	6	180B141   514	2233003039	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.18968	-118.4763	(ePlan) PLAN CHECK FOR PV ROOF MOUNTED SYSTEM, SYSTEM SIZE:9.52KW DC, 8.641KW AC  CONSISTING OF 1 CENTRAL INVERTER(SE7.600H-US 7.6KW) WITH 34 MODULES USING P320 OPTIMIZERS. CONNECTED TO EXISTING 200A SERVICEFEES $79.84 DUE TO CALIFORNIA SENATE BILL 1222 AND AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48508	19041-30000-46957	12775 W MILLENNIUM UNIT 140A-140B	90094	11	102B161  1237	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	33.97584	-118.4171	ENERGY PLAN CHECK ONLY, AREA OF SCOPE 1812SFBUILDING PERMIT # 19016-30000-18981	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48509	17041-20000-09874	12601 W PIERCE ST BLDG 43	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for installation of solar pv array, roof-mounted on apartment building (building 43).3kW AC/ 2.8kw DC ungrounded system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48510	11041-20000-01654	11021 W MCCORMICK ST	91601	4	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	34.16608	-118.37101	Plan check for power and energy for new work on ground floor of mixed-use building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48511	13041-10000-12144	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM			PC Approved	05/21/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	((permit to be pulled at EPC counter only))pc for energy only. TI TO EXISTING BUILDING OFFICES (mailroom,lactation room, office and supporting corridors). for cedar-sinai.  emergency lighting from generator. NOT MEDICAL and <400A PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48512	13041-10002-12614	9040 W PICO BLVD	90035	5	132B169   879	4305007029	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.05505	-118.38885	10-15-15Changes to an approved set, note changes on delta 6. scope includes new lighting fixtures. T-24 still qualifies under 2008 standards. All permit fees covered under 10001. (((pc for power and energy. CHANGE OF USE FROM EXISTING ONE STORY FURNITURE BUILDING TO AN ORTHODOX SYNAGOGUE INCLUDING PARTIAL DEMO  15215 SF)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48513	12041-20000-27321	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for energy and emergency lighting. restroom in 21st floor of commercial high-rise. 481 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48514	14041-10000-19188	1217 W PASEO DEL MAR	90731	15	006B193   361	7470031009	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	33.71325	-118.30682	Installation of roof mounted solar system.  Total system size = 2.5 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48515	14041-10000-25178	814 W 23RD ST	90007	1	123A203    94	5124029017	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			Verifications in Progress	10/31/2014 12:00:00 AM	ADDRESS	34.03246	-118.27812	REPLACE NEW FIRE PUMP INCLUDING FEEDER AND  JOCKEY PUMP IN HAZARDOUS LOCATION (OIL PUMP FIELD).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48516	14041-20000-26042	19755 W VANOWEN ST #6	91306	3	183B117  1051	2135022044	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.19397	-118.56386	TI TO RETAIL SPACE. PC FOR ENERGY ONLY. NEW LIGHTING. 2013 ENERGY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48517	14041-20000-18919	5555 N CAPISTRANO AVE	91367	3	174B101   260	2040014001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.17152	-118.61691	7.9KW PV1 roof-mounted system with (31) Trina Solar TSM -255P modules and SolarEdge Power Optimizers, and a SolarEdge SE6000A inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48518	12041-10000-19241	3984 N TARRYBRAE TER	91356	3	162B117   115	2180004017	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	34.14229	-118.56067	New 9.8kw rooftop, photovoltaic system using DC/DC Converters.  System is ungrounded.  Misc. Permit is for the DC/DC Converters.  Plan check is for PV system only.  NOT for reducing the main breaker size.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48519	19041-10000-29251	110 E 9TH ST A1094	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM			PC Info Complete	07/29/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	PC for T24 for a TI in the 10th floor of a 14 story highrise, connected load is under 400A. Scope of work includes new lighting, controls,  and receptacles. Total affected area is 12950 sqft. B#: 19016-10000-20863	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48520	12041-10000-26979	5657 W WILSHIRE BLVD	90036	4	135B181   885	5508014002	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Approved	11/08/2012 12:00:00 AM	ADDRESS	34.06262	-118.35187	PLAN CHECK FOR ENERGY. TI FOR EYEGLASS STORE. 1076 SF. 5 STORY UNIT EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48521	19041-10000-42120	655 N LA FAYETTE PARK PL	90026	10	133-5A201  60	5077006901	OS-1XL	Central	Wilshire	MacArthur Park, Rampart Village, Wilshire Center-Koreatown		2122.04	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			Reviewed by Supervisor	10/23/2019 12:00:00 AM	ADDRESS	34.0779	-118.274	POWER PLAN CHECK FOR 400A SERVICE 120/208 3PH 4W. T-24 EXEMPT.UPDATE ADDRESS BEFORE FINAL PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48522	13041-30000-25537	11715 W SAN VICENTE BLVD 1st fl	90049	11	132B145   522	4401017021	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	PIN	34.05384037	-118.46676399	NEW CANS AND NEW FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48523	14041-10000-11607	380 WORLD WAY Space T72	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	TITLE 24 ONLY. PERMIT TO BE PULLED UNDER INSPECTION. PROPOSED 541 SQFT  TENENAT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE ( Drink LA). T72  level 5.Plans were lost on this application#: 13041-10000-05746	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48524	17041-10001-31743	6569 W DE LONGPRE AVE	90028	13	147A187   258	5547026041	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	34.09624	-118.33278	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48525	13041-20000-35006	5330 N NEAL DR	90041	14	163-5A223  50	5671007018	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.14354	-118.21284	PV1 CENTRAL INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48526	12041-10000-04247	1031 E 34TH ST	90011	9	117A209   345	5114018009	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Expired	03/20/2014 12:00:00 AM	ADDRESS	34.01288	-118.25755	this is new fire alarm for 5 story bldg, commercial, B occupancy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48527	15041-10000-15301	600 WORLD WAY # 622	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	"T24 ONLY. INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM ROW. COPY TO READ ""STARBUCKS COFFEE"". TOTAL AREA 13.45 SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48528	14041-10003-14670	401 S GRAND VIEW ST	90057	1	135A203   316	5154036012	R3-1	Central	Westlake			2088.02	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM			PC Approved	06/02/2016 12:00:00 AM	ADDRESS	34.06322	-118.27542	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 REVISION. CHANGES INCLUDE UPDATE SERIES RATINGS AND SHORT CIRCUIT INFO.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48529	16041-20001-35905	10831 N ANDORA AVE	91311	12	207B105    84	2722005004	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.26698	-118.60339	12.6.2016 - Plan check for modifications to approved set. Modified interconnection point - connecting to new subpanel. Changes clouded.=====PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.2KWac.(60)MODULES-Q-CELLS 275W(60)OPTIMIZERS-SOLAREDGE P300(2)INVERTERS-SOLAREDGE SE7600A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48530	19041-10000-47074	384 WORLD WAY SPACE M38	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			Corrections Issued	03/05/2020 12:00:00 AM	ADDRESS	33.94339	-118.40887	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT - STARBUCKS - NEW APPROX 200A OF CONNECTED LOAD WITH TOTAL AFFECTED AREA = 1198 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48531	10041-20000-16768	10350 W OLYMPIC BLVD	90064	5	129B161   148	4315018001	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00, 2679.00	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.05139	-118.4185	400 Square Foot remodel (RETAIL). P/C IS FOR ENERGY ONLY. THERE IS EXISTING PERMIT FOR UNDER 10041 30000 13814 FOR 200 AMP SERVICE AND ONE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48532	17041-10000-02947	10285 S POST WAY	90045	11	087B165    13	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	33.94231	-118.39697	NEW VERIZON CELL SITE CONCISTING OF NEW MONOPOLE WITH ANTENNASS., NEW GROUND. (LAX ATTN: EDUARDO)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48533	14041-10000-01859	10555 CORBIN AVE	0	12	207B117   290	2708010***	(T)(Q)RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth, Northridge West	YES	1131.02	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM				OUTDOOR LIGHTING FOR A PRIVATE STREET. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48534	19041-30000-00275	14006 W RIVERSIDE DR #265	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Issued	05/30/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 2,039 sq. ft.Note: Building application has been generated under 18016-10000-40730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48535	17041-20001-44177	4551 N CONCHITA WAY	91356	3	168B117   531	2178028002	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.15384	-118.55926	Expedited plan check fee. PV1.  Install 17.64 kW roof mounted grid tied PV system.  (49) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48536	17041-10000-00119	6801 W HOLLYWOOD BLVD STE 235-SPC B2-241	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.10229	-118.33907	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL/STORAGE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A JEWELERY STORE. TOTAL AFFECTED AREA IS 822 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48537	16041-10000-10366	15260 W VENTURA BLVD 1ST,3RD,-4TH,5TH	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	ADDRESS	34.15356	-118.4658	COMMERCIAL INTERIOR TENANT IMPROVEMENT ON 1ST, 3RD, 4TH, AND 5TH FLOORS. NEW CONNECTED LOADS LESS THAN 400A, PC FOR T-24 ONLY. TOTAL AREA: 6,998 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48538	16041-20001-40355	18771 W WILLOWTREE LANE	91326	12	207B121   529	2728029072	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	34.26304	-118.54197	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (42) modules, (42) micro-inverters, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48539	16041-10000-27449	1924 E 103RD ST	90002	15	091-5A215 134	6066001041	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.94303	-118.23811	PC for energy only to an existing commercial space. Change of use from retail store to a juice bar. Adding new lighting and power. New 100 amps panel, newly connected load is less than 400 amps. Total sqft = 1125.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48540	18041-10000-22038	6361 W SANTA MONICA BLVD	90038	13	144B185   688	5533008011	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	08/24/2020 12:00:00 AM	ADDRESS	34.09087	-118.32815	FULL PLAN CHECK FOR CHANGE OF USE FROM OFFICE TO SCHOOL BUILDING. REUSING EXISTING 2000A SERVICE, INSTALL (3) 100 A PANELBOARDS, REUSING (4) EXISTING PANELBOARDS FOR NEW LOADS. TOTAL AREA FOT T24: 22,412 SQ.FT (INDOOR + OUTDOOR)(B# 18016-10000-13243)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48541	15041-20000-28642	916 S VICTORIA AVE	90019	4	132B189   885	5090034024	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.05619	-118.32338	PV1. Install roof mounted PV system sized 4.2 kW. Interconnected with main service panel.(17) LG280 Modules(1) PVI-4.2 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48542	18041-10000-19678	10608 W SANTA MONICA BLVD 1-28	90025	5	129B157   123	4321003035	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			05/25/2018 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	11/17/2020 12:00:00 AM	ADDRESS	34.05329	-118.42955	Full plan check for a new AFFORDABLE HOUSING 28-unit, 6-story Apartment over 1-level subterranean Parking Garage. Scope includes a 1400-Amps service and (6) typical units.Building permit # 17010-10000-00780	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48543	13041-10002-30044	6382 W RIGGS PL	90045	11	102B165   123	4110012010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	33.97801	-118.39895	Expedited RSES plan check per applicant request.(((PV1, Install 8.48 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 32 modules Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48544	16041-30000-29977	16792 W CHARMEL LANE	90272	11	132B117    32	4420026011	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.05981	-118.55155	Plan check for PV roof mounted system. system size: 14.8kW with 43 modules and 43 AC modules connected to existing MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48545	14041-10000-33351	744 E PICO BLVD	90021	14	123A211   160	5132019042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.03202	-118.25256	REMODELING & ADDITION  TO  (E)  2-STORY RETAIL & STORAGE & OFFICE  MALL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48546	18041-20000-12992	16929 W DEVONSHIRE ST	91344	12	204B133   147	2684012044	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.25767	-118.50122	PC for T24 only for new lighting for change of use from retail to restuarant. Installing new lights, receptacles and equipment. B#17016-20000-28924.CHANGE OF USE FROM RETAIL TO RESTAURANT (1600 SQ FT). SEE COMMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48547	16041-10000-05161	4330 W SUNSET BLVD	90029	13	145-5A201  13	5429006003	C2-1D	Central	Hollywood	Los Feliz		1913.02	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Info Complete	02/12/2016 12:00:00 AM	ADDRESS	34.09512	-118.28377	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RESTUARANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR RESTUARANT. TOTAL AFFECTED AREA IS 1640 SQ. FT.*** NOTE, INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT NUMBER 16041-10000-05952.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48548	16041-20001-02580	5410 N RHODES AVE	91607	2	171B165    39	2347006***	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			01/25/2016 12:00:00 AM			PC Approved	01/30/2016 12:00:00 AM	ADDRESS	34.16912	-118.40293	EXPEDITE PER APPLICANT REQUESTInstall a roof mounted solar array on an apartment building. Interconnect with a 400A MSP.System size: 8.2kW + 6kW = 14.2kW, ungrounded system. (63) 265W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48549	17041-10000-12555	10250 W SANTA MONICA BLVD STE. 1470	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for ""APPLE STORE"" Ste. 1470 at Westfield Century City.  Install new electrical equipments,  total affected area: 10,914 sq.ft"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48550	18041-10000-19931	6761 S ARLINGTON AVE	90043	8	102B189   869	4008017030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	33.97655	-118.31885	PC FOR ROOF MOUNTED PV ON SFD WITH ESS (ON SUPP. PERMIT). SCOPE INCLUEDS 10 MOUDULES WITH CENTRAL INVERTER. TOTAL SYSTEM SIZE 3.3KWAC/3.05KWDC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48551	16041-30000-01075	7932 N ROYER AVE	91304	12	189B097   527	2014023017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.21472	-118.62746	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48552	13041-10001-36253	11272 N ESKO AVE	91342	7	210B181    33	2550003025	A2-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.27493	-118.34728	Expedited RSES plan check per applicant request.{{PV1, Install 7.25 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US. (29) Modules: Trina Solar TSM-250PA05.18.(29) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48553	13041-20000-28799	16238 W LONDELIUS ST	91343	12	195B137   775	2688016003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.22917	-118.48652	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING 28 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48554	16041-20000-27560	642 N PERUGIA WAY	90077	5	141B149   189	4362003009	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.08098	-118.44933	Plan check for power only. Scope includes a new 800 A 120/240 single phase 4w service for a new 2 story single family dweling home.PERMIT FEES PAID UNDER APPLICATION NUMBER 12041-10000-02209	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48555	12041-20001-10008	8053 W BEVERLY BLVD	90048	5	138B177   392	5514007045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM			PC Approved	02/22/2013 12:00:00 AM	ADDRESS	34.07625	-118.36499	REPLACEMENT OF SERVICE AND SOME TENANT  PANEL BOARDSELIMINATE CONDUIT METHANE SEAL OFF ALL CONDUITS AND SERVICE OVERHEARD SEAL IS NOT REQUIRED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48556	15041-10000-33647	20821 W DEARBORN ST	91311	12	198B109   130	2748036012	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.23735	-118.58684	PC for energy. remove HID light fixtures and replace with LED fixtures. total area 9756 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48557	17041-10000-09582	8510-8512 S WESTERN AVE 1-2	90047	8	097-5A193 267	6034030042	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/05/2021 12:00:00 AM	ADDRESS	33.96053	-118.30882	Plan check for power and TItle-24.  Core and shell for new 2 story commercial building with surface parking.  First floor is retail and 2nd floor is office.  New 600 amp service with 5 subpanels.  Total area = 2,676 sq. ft.          Building permit #16010-10000-00060	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48558	17041-10000-19841	7320 N FIGUEROA ST	90041	14	162A229   338	5481013029	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			Reviewed by Supervisor	06/20/2017 12:00:00 AM	ADDRESS	34.13633	-118.18806	Installation of new roof mounted solar PV system on existing commercial building.  Microiverter system.  Total size = 12.75 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48559	19041-10000-52066	1314 N HOOVER ST	90027	4	147A201   206	5430032016	R2-1XL	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.09624	-118.28392	New PV1 roof mounted installation with a system size of 4.8KW DC/ 5KW AC, with 16 modules (SLA-M-300), 16 power optimizers (P320), 1 central inverter (SE5000H-US), and a main service panel rated for 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48560	17041-10003-11390	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Approved	09/15/2018 12:00:00 AM	ADDRESS	34.10222	-118.32701	DELTA 1 CHANGES TO AN APPROVED PLANS. CHANGING COPPER FEEDERS TO ALUMINUM.PANELS 2EB, 2EC AND 6EA HAVE BEEN UPDATED TO 22KAIC FOR AVAILABLE FAULT CURRENT. ELEVATOR CONDUCTORS SHALL BE #1AWG(CU) MIN<<<FULL PLAN CHECK INTERIOR AND EXTERIOR RENOVATION FROM GROUND FLOOR (1) TO ROOF (6) FOR EXISTING  HOTEL, NO CHANGE IN USE. EXISTING 2000 AMP SERVICE 120/208V 3PHASE 4WIRE. NEW DISTRIBUTION BOARDS BEING ADDED, NEW PANELS. 5 TYPICAL UNITS. NEW INDOOR/OUTDOOR LIGHTING. PANELS. AREA: 36,440. BLDG # 17016-10000-08652.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48561	08041-10001-19822	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM			PC Approved	01/20/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	Revision to approved set of plans: in  one section of a building , a 225KVA transformer is to be relocated to the second floor and be supplied from an outside feeder from the main swbd  MSC supplying the building. This transformer will supply swbd MSA which is on the first floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48562	17041-10000-41596	180 S LA BREA AVE	90036	5	138B181  1246	5513018017	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.07124	-118.34383	PC FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY!SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 1972 SQ.FTB# 17016-10000-27740INTERIOR TI  <<SECOND  RESTAURANT(1670SF)  CONSTRUCTED WITH NEW DEMISING WALL(17016-10000-16799) WITHIN EXISTING RESTAURANT TENANT SPACE>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48563	14041-20000-17690	1755 N GLENDALE BLVD	90026	13	144A209   285	5423006033	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.08742	-118.25984	TI for (N) yoga studio.  Power and energy per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48564	19041-10000-18372	5905 W WILSHIRE BLVD	90036	4	135B177   424	5508016902	PF-1D	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.06282	-118.35793	ADDITON OF AN EXTERIOR LIGHT FIXTURE TO AN EXISTING POLE FOR AN ADDITION OF AN OUTDOOR SHIPPING AND RECIEVING DOCK.T-24 ENERGY ONLY.BULDING PERMIT: 19020-10000-01294	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48565	19041-10001-44374	1034 S MARIPOSA AVE	90006	1	129B197   366	5078016017	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.05169	-118.2988	PLAN CHECK ONLY.CHANGES TO AN APPROVED SET. SCOPE OF WORK INCLUDES ADDITION OF LIGHTS AND WATER HEATER CIRCUIT. CHANGES ARE IN CLOUDED UNDER DELTA 1**Inspection fee under permit number: 19041-10000-44374	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48566	13041-10000-28201	800 W WILSHIRE BLVD main lobby	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.0493	-118.25841	Title 24 part 6,lighting,  plan check only for a high rise commercial building. Tenant improvement is for the main lobby.Adding 4 total fixtures. Total area is 1300sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48567	14041-20000-27792	8335 W MELROSE AVE	90069	5	141B173   436	5528003198	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			Corrections Issued	10/07/2014 12:00:00 AM	ADDRESS	34.0838	-118.37143	PC FOR TI. RETAIL STORE. NEW TRACK LIGHTING. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48568	17041-10000-27773	2510 W TEMPLE ST Unit 101-102	90026	13	138A205   221	5157008029	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.07192	-118.27348	PC for power and energy for first time tenant restuarant TI. Installing two new panels, new circuits, new lights and equipment. Total affected area of 1871 sqft. Building #17016-10000-15550.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48569	15041-20000-11253	3415 S SEPULVEDA BLVD Suite 1100	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM			PC Approved	04/15/2015 12:00:00 AM	ADDRESS	34.02055	-118.42347	Title-24 plan check only. Total area = 535 sq. ft. T.I. to existing office space in commercial highrise. New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48570	14041-10000-07344	1616 S FLOWER ST	90015	14	124-5A205  56	5134008006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.03649	-118.2689	PLANCHECK FOR T24 ENERGY. TI. NEW LIGHTING FOR A STORAGE. REPLACE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 17602 SQFT. ALL WORK TO BE INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48571	15041-20001-05183	612 S FLOWER ST 1st Floor	90017	14	129A209   264	5144005124	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM			PC Approved	07/02/2015 12:00:00 AM	ADDRESS	34.0497	-118.25759	07/02/2015 Changes to an approved set of plans. All changes have been clouded. Changes include the addition of how the EM lights tie into the EM generator/lighting panel.*****Previous Work Description*****Plan check for Title 24 energy only. Tenant improvement to existing restaurant on the first floor of a high rise building. New lighting including emergency. Total lighting area = 7,307 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48572	17041-10000-02694	3960 S BILL ROBERTSON LANE	90037	9	117A201     1	5037027937	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.01294	-118.28998	(N) 2 STORY BUILDING. WAREHOUSE ON FIRST WITH OFFICES ON 2ND. NEW SERVICE 1200A WITH FULL BUILD OUT. PC FOR POWER AND ENERGY.B# 17010-10000-00146	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48573	16041-30001-30753	3313 S BUTLER AVE	90066	11	117B157   123	4250019004	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM			PC Approved	09/30/2016 12:00:00 AM	ADDRESS	34.02003	-118.43039	Expedite per applicant requestPlan check for PV roof mounted system. System size:10kW with 36 modules and  2 inverters(5.0kW each) connect to MSB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48574	15041-20000-15220	1055 W 7TH ST 15th floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.0507	-118.26334	Plan check Title 24 only for LA Care T.I. office space 15th floor . Total area: 17,564 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48575	19041-10000-10891	4424 N BERGAMO DR	91436	5	165B137    59	2284016027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.15206	-118.48686	$0.00 fee due to senate bill12222 and AB1414Plan check for a 18.9KW AC / 18.36KW DC PV1 roof mounted system with (68) modules, (2) inverters, (1) subpanel interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48576	11041-10000-27049	4867 W SUNSET BLVD	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			12/20/2011 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Closed	10/17/2014 12:00:00 AM	ADDRESS	34.09832	-118.29564	Temporary 1200A power  for a construction of a new Kaiser hospital building. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48577	17041-10000-03298	5126 W WILSHIRE BLVD	90036	4	132B181    36	5507026022	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.06197	-118.34164	Plan check for Title 24 only change of use from retail to office T.I. Total area: 6,663 sq ft. Load under 400A.B#:16016-10000-31153	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48578	19041-20000-46000	350 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A203 152	5111003039	M1-1-CPIO	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			Corrections Issued	11/08/2019 12:00:00 AM	ADDRESS	34.01092	-118.27958	Temp power for (E) commercial building.  (2) 800 kVA and (1) 600 kVA vehicle mounted generators to feed (E) distribution equipment.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48579	16041-20004-30985	18957 W CARMEL CREST DR	91356	3	162B121   162	2177048014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.14115	-118.5437	5.11.2017 - Plan check for modifications to approved set.  Clouded revisions to line diagram.  4.27.2017 - Plan check for modifications to approved set. Revise roof layout, and reduce total number of pv modules to (31). Change model/manufacturer of pv modules, new modules have a rating of 325W. Changes clouded.========02/03/2017 Changes to an approved set of plans. System size has increased from 7.6 kWac to 10.6 kWac with the addition of (1) inverter, (2) modules, and (1) load center, for a total of (2) inverters, (34) modules, and (2) load centers. System is a battery back-up PV system.*****Previous Work Description*****PV1INSTALL ROOF MOUNTED PV SYSTEM WITH BATTERY BACK UP SIZED 7.6KW INTERCONNECTED WITH MSP.$10.37 permit fee is due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48580	19041-10000-33993	1771 W BLAKE AVE BLDG 1	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Corrections Issued	10/01/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	1 OF 11. BLDG 1POWER PLAN CHECK FOR 1200A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDING AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48581	15041-20000-02642	938 S MENLO AVE	90006	1	132B197  1049	5076002026	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	03/07/2015 12:00:00 AM	ADDRESS	34.05451	-118.29021	Roof mounted PV system with Enphase (M250-60-2LL).  Total system size 4KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48582	16041-10000-43277	1925 S COMPTON AVE	90011	9	118-5A213   1	5129014020	M1-1, M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.02025	-118.24425	PC for enrgy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total sqft: 85450	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48583	16041-10000-30643	835 W JEFFERSON BLVD 7-D	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	TI FOR OFFICE SPACE IN EXISTING ROOM. NEW LIGHTING. WORK DONE IN BUILDING 7 SUITE 7-D PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48584	16041-10000-45512	6000 N SEPULVEDA BLVD MMO	91411	6	177B145   439	2242026009	M3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.17961	-118.46592	PC for T24 for office space in Westfield Mall. Total affected area is 2675 sqft. Site on Methane Buffer zone with work being done above grade (Not a Hazardous location). Installing new lights and receptacles/ . Total isntalled load is uner 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48585	18041-20000-40768	1701 S LA CIENEGA BLVD	90035	5	129B173  1254	4303027042	C2-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.04701	-118.37637	New fire alarm system for nursery building.   (59) signaling line and notification devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48586	13041-10001-10577	19215 W VENTURA BLVD	91356	3	174B117   686	2163019013	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.17277	-118.55159	CHANGES TO APPROVED SET. Bugeye unit equipment removed. Emergency lighting supplied by battery backup for luminaies. T24 energy calcs and information updated.. TI TO GOODWILL INDUSTRIES. EXISTING BLDG. <400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48587	13041-20000-07833	3330 N ALANA DR	90049	5	159B141   341	2280023011	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	PIN	34.13196211	-118.47791486	New photovoltaic system for an existing single family residence.  Rooftop mounted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48588	17041-30000-07224	550 S HOPE ST STE 2640	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.04989	-118.25574	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 231 sq. ft.Note: Building permit has been pulled under 17016-10000-02965	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48589	17041-10001-30791	112 S LA BREA AVE	90036	5	138B181   894	5513018003	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.0731	-118.34383	This is plan check only for T24 per inspection request. Permit is obtained online under # 17041-90000-30791. Retail store remodel, new lighting and controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48590	19041-10000-08056	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	33.95887	-118.41869	T-24, PLAN CHECK FOR LIGHTING ONLY. SCOPE OF WORK INCLUDES REPLACEMENT OF EXISTING FIXTURES IN MEN'S AND WOMEN'S PUBLIC RESTROOMS IN AN EXISTING HOTELAT LEVEL 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48591	15041-10000-02367	819 S SANTEE ST	90014	14	126A211    46	5145013005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.04107	-118.25233	Plan check for a fire alarm system. System consists of (1) FACP, (4) RPSs, and (406) devices. Project is a residential high-rise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48592	16041-20000-32165	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022	A1-1-H, A2-1, PF-1XL, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.08694	-118.47588	Plan check for energy only. New driveway/entrance lighting for Getty Center. Outdoor T24 - 29,313sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48593	19041-20000-37430	291 S GLENROY AVE	90049	5	138B145   673	4366017034	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	05/21/2020 12:00:00 AM	ADDRESS	34.07044	-118.4606	Plan check for PV roof  mounted system and Energy storage system, PV system size: 8.38KW DC, 7.54KW AC CEC with 25 PV Modules and 25 microinverter and 1 Tesla Battery(13.5KWh)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48594	16041-20001-21206	10347 W DIAMOND ST LOT 8	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48595	11041-20000-19999	8928 N SEPULVEDA BLVD	91343	7	195B145   150	2654005015	M1-1	North Valley	Mission Hills - Panorama City - North Hills			1175.10	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.23317	-118.46736	PLAN CHECK POWER AND ENERGY FOR 2-STORY NEW OFFICE BUILDING WITH 800A SERVICE. PLAN CHECK DOES NOT INCLUDE 8938 N. SEPULVEDA BLVD BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48596	15041-10000-18728	12446 W OSPREY LANE 1-3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	33.97949	-118.41001	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'A'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'A' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48597	17041-10000-22296	6300 W WILSHIRE BLVD 1900	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for T24 only, TI on the lounge area Suite 1900, area 568 sq.ft.   ((B#17016-10000-12905))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48598	16041-20002-08449	14755 W VENTURA BLVD	91403	4	166-5A149  15	2265001006	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM			PC Approved	05/20/2016 12:00:00 AM	ADDRESS	34.15211	-118.4549	05/20/2016 Changes to an approved set of plans. Changes have been made to the light fixtures. All changes have been clouded and marked as Delta 2. All changes have been reflected onto the Title 24 Compliance Forms.05/04/2016 Changes to an approved set of plans. Changes have been made to the light fixtures. All changes have been clouded and marked as Delta 1. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,226 sq. ft.Note: Building permit has been pulled under 16016-10000-04236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48599	11041-10000-21544	10000 W PICO BLVD BLDG 4	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/21/2011 12:00:00 AM	ADDRESS	34.05211	-118.40654	"New ""Gateway Building"" - Building 4 at Hillcrest Country Club.  PLAN CHECK ONLY for Energy with Emergency lighting."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48600	12041-10000-11386	1200 S CLUB VIEW DR 1-35	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00, 2657.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.06748	-118.42481	NEAR APT 1201, A COMMOM CORRIDOR IS BEING BUILTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48601	15041-20000-05493	355 S GRAND AVE #01605	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.05191	-118.2525	TI TO OFFICE SPACE. PC FOR T24 ENERGY ONLY. WORK DONE IN SUITE 1605/. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48602	19041-10000-52705	1801 E 53RD ST	90058	9	108B213   113	5105008903	RD2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM			PC Info Complete	12/20/2019 12:00:00 AM	ADDRESS	33.99477	-118.24059	PLAN CHECK FOR TITLE 24 ONLY. SCOPE OF WORK INCLUDES NEW LIGHTS TO AN EXISTING SPACE. TOTAL AFFECTED AREA IS 2431 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48603	14041-10000-13068	12760 W MILLENNIUM	90094	11	102B161  1239	4211037053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/15/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	"METHANE MITIGATION PER SUPERVISOR. parcel 4A, Building A.  methane zone design level 4 with <= 2"" of water column."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48604	13041-20000-29695	333 S GRAND AVE 20TH FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	T24 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON THE 20TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48605	14041-10001-14463	13140 W ADDISON ST	91423	4	171B157  1111	2358009025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.16112	-118.41949	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{[PV1, INSTALL 11.47 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48606	19041-20000-48482	22139 W CANTLAY ST	91303	3	186B101   961	2023010020	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.20209	-118.60946	PV1 PLAN CHECK FOR NEW PV. SYSTEM SIZE IS 5.475 KW DC/4.35 KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48607	19041-20000-15553	225 S LINCOLN BLVD	90291	11	111B145   529	4240019061	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.00183	-118.46926	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,210 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48608	11041-20000-22207	6338 W 77TH ST	90045	11	102B165   886	4109003020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2011 12:00:00 AM	11/03/2011 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	33.97197	-118.39759	Plan check for Enphase Microinverter photovoltaic system single family dwelling. Variance to allow installation of M215 prior to testing agency approval or listing has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48609	15041-20000-35242	7214 N TOPANGA CANYON BLVD	91303	3	183B101    43	2111022007	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.20151	-118.60569	TI TO SECOND FLOOR. NEW MASSAGE, SPA. PC FOR T24 ENERGY ONLY.PERMIT TO BE ISSUED FOR FULL TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48610	14041-10000-22907	12839 W SYLVAN ST	91606	2	177B161    96	2332002018	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.185	-118.41303	PV1, INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: KYOCERA KD255CX-LFB3(1) POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48611	18041-20001-00413	13100 W GRIDLEY ST	91342	7	222B161    19	2512027030	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/15/2018 12:00:00 AM	ADDRESS	34.30958	-118.41836	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (10) modules, (1) load center, and (1) Tesla PowerWall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48612	16041-30000-24377	1490 W 7TH ST Suite 1494	90732	15	015B193   350	7452034042	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	33.73806	-118.30936	Plan check for power and energy. Project site is an existing tenant space within a commercial building. Project scope is a tenant improvement. Total lighting area = 1,304 sq. ft.Note: Building permis has been pulled under 15016-40000-27240	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48613	17041-20000-08019	3435 N ARDSLEY PL	91436	5	159B133   247	2292022015	(T)(Q)RE40-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	PIN	34.13114578	-118.50309081	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 400A MSP.13.23kW ungrounded system. (49) EnPhase S280 microinverters. (49) 320W pv modules.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48614	18041-20001-47384	3744 S MEIER ST	90066	11	111B153   359	4246018014	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM			Ready to Issue	04/18/2019 12:00:00 AM	ADDRESS	34.00238	-118.44081	$0 FEE DUE TO SB1222 AND AB1414Changes to approved set, addition of 5 more PV modules, change to a SE7600H inverter, and change to delta 2 wire size. System size is now 7.68KW DC/7.6KW AC clouded changes only*Original*Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48615	19041-10000-05760	4305 N VINELAND AVE	91602	4	165B173   552	2423013900	PF-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.14828	-118.37052	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48616	10041-10000-01876	12000 S VISTA DEL MAR F.O.G.	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	PIN	33.92817449	-118.43220714	New electrical for FOG and food waste containment site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48617	17041-20002-26736	11000 N NOBLE AVE	91345	7	210B145   362	2615011009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Issued	01/19/2018 12:00:00 AM	ADDRESS	34.26922	-118.45942	0/19/2018 Changes to an approved set of plans. PV system size has increased from 5 kWac to 6 kWac, the module count has increased by 1, for a total of (20) modules, and AC disconnects have been added to the Tesla PowerWalls.*****Previous Work Description*****pv1install roof mounted pv system sized 5kw with (2) battery backup tesla powerwalls interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48618	14041-10000-11061	1750 S SAWTELLE BLVD 1-15	90025	11	126B149   206	4261019019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			04/28/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.04429	-118.44625	NEW THREE STORY 15 UNITS APARTMENT BUILDING WITH TWO LEVEL BASEMENT PARKING.Plan check for power and energy - two typical types of units.  No title 24 was provided, fees have to be added later.  Methane buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48619	18041-10000-00989	21800 W MARILLA ST	91311	12	201B105   152	2746016900	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.24747	-118.60346	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 6900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48620	15041-10003-20170	6421 W SELMA AVE	90028	13	148-5A187 303	5546007023	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.09988	-118.33029	02/16/17CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 7. CHANGES INCLUDE REVISING FLOOR PLANS, SINGLE LINE DIAGRAM, AND ELECTRICAL ROOMS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48621	19041-20000-20264	4301 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   250	5045001008	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.01679	-118.34427	NEW FIRE ALARM SYSTEM FOR 3-STORY MIDDLE SCHOOL AND GYM.  (1) FACP, ANNUNCIATOR AND (204) FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48622	15041-10000-03106	12918 W KELOWNA ST	91331	7	204B161   459	2623023025	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.25459	-118.41397	PV1, 3KW AC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE,(11)  MODULES SUNPOWER SPR-327NE-WHT-D (1) SMA AMERICA SB 3000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48623	19041-10000-17701	14024 W OSBORNE ST	91331	6	195B153   260	2640016025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.23313	-118.43803	TI to an existing mcdonalds, scope of work includes adding and removing light fixtures. Affected area is 236 sqft. BLDG# 19016-20000-13666Note: change assingment, applicant has one check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48624	19041-10000-09636	1951 N GAFFEY ST	90731	15	024B197    78	7442022021	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	33.76336	-118.2935	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48625	11041-20000-04480	6301 N OWENSMOUTH AVE 11TH FL	91367	3	177B105   123	2146029016	WC	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/21/2011 12:00:00 AM	ADDRESS	34.18467	-118.60176	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT 11TH FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48626	16041-10000-26904	643 N LA CIENEGA BLVD	90069	5	141B173   532	4337003052	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.08325	-118.37674	FULL PC FOR POWER AND ENERGY. TI TO AN (E) RESTAURANT/NIGHT CLUB. ASSEMBLY OCCUPANT LOAD > 100. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 9000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48627	10041-20000-19671	21605 W PLUMMER ST	91311	12	201B105   245	2746015014	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Expired	09/19/2014 12:00:00 AM	ADDRESS	34.24286	-118.60083	Plan check T-24 Energy (general/emergency) lighting for TI (Phase I and Phase II) in Sanyo building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48628	12041-20000-18179	8150 N LANKERSHIM BLVD	91605	6	192B169   605	2311005001	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Approved	08/13/2012 12:00:00 AM	ADDRESS	34.21902	-118.38758	T.I. to existing building.  Install new general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48629	17041-20000-33666	5020 W SANTA MONICA BLVD	90029	13	144B197  1452	5538002***	C2-1D, R3-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Apartment			09/20/2017 12:00:00 AM			PC Info Complete	09/20/2017 12:00:00 AM	ADDRESS	34.09059	-118.29871	relocate electrical room , add car chargers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48630	12041-10000-10057	9400 N OAKDALE AVE	91311	12	198B113    97	2761040801	MR2-1	North Valley	Chatsworth - Porter Ranch			1133.03	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.24135	-118.56674	PLAN CHECK FOR NEW NATURAL GAS FUELING SYSYEM IN HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48631	15041-20000-03148	8912 S MANHATTAN PL	90047	8	096A193   218	6036017031	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	33.95588	-118.30999	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.3kW Ungrounded system.(20) EnPhase M215 microinverters with (20) 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48632	19041-10000-02444	100 WORLD WAY LAX TER-1-Level 3	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	Plan check for an interior display sign	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48633	10041-10000-23509	305 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Closed	05/17/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY  ( 2-DAYS ) STANDBY GENERATOR  TO SUPPLY POWER TO EACH OF TWO MCC WHICH POWERS EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48634	16041-10000-19127	1789 W JEFFERSON BLVD	90018	8	120B193   699	5053008008	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.02571	-118.30865	Change of use from KFC to NEW STARBUCKS WITH DRIVE-THRU, 600A service. PC for Power and energy. Total area: 1,930 sq.ftB# 16016-10000-12575	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48635	16041-10000-43635	401 E 2ND ST	90012	14	129A215   144	5161018007	[Q]C2-3D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.04771	-118.23908	PC FOR T24 ENERGY ONLY. REPLACING OLD LIGHTS FOR NEW LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48636	16041-20001-24362	11647 N SWINTON AVE	91344	12	213B137   255	2605018028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.28207	-118.48558	RSES expedited plan check fee per applicant request.  PV1.  Installation of 11.75 kW roof mounted PV system.  (41) modules with (2) 6 kW rated inverters with power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48637	16041-10000-18256	8436 W 3RD ST	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Issued	07/08/2016 12:00:00 AM	ADDRESS	34.07301	-118.37448	FA SYSTEM. 112 DEVICES. MOB RETROFIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48638	15041-10000-20987	6223 W SELMA AVE	90028	13	148-5A189 286	5546028033	C4-2D	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.09991	-118.32451	ADD EXTERIOR LIGHITNG TO AND EXISTING PARKING LOT. PLAN CHECK FOR ENERGY ONLY.  TOTAL HARDSCAPE 17,205.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48639	18041-10000-44548	380 WORLD WAY Space T-18	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR TENANT IMPROVEMENT FOR  EXISTING RETAIL STORE. TITLE 24 ONLYTOTAL SQFT: 583	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48640	14041-10000-09422	12156 W WIXOM ST	91605	2	189B165  1021	2307010004	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.21111	-118.39852	PV1 5KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(20)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48641	15041-10000-11679	611 W 124TH ST	90044	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	33.92019	-118.28524	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48642	12041-20000-15548	920 W BLOOM WALK	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			PC Approved	07/05/2012 12:00:00 AM	ADDRESS	34.01996	-118.28938	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48643	14041-10000-15410	5101 N WOODLEY AVE	91436	5	171B141   395	2260020013	RA-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.16222	-118.48386	PV1, Install 10.45 KW DC roof-mounted solar array on a 1-story house, interconnect with main service panel. Transformerless inverter. With optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48644	13041-20000-35624	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	T24 FOR EXISTING RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48645	18041-10000-09232	4850 N NOMAD DR	91364	3	168B113   101	2175017009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.15936	-118.5676	PC TO ADD AC DISCONNECT ON EXISTING INSTALLATION OF two  Tesla Powerwall2 units connecting to backup subpanel and existing solar system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48646	13041-10000-08247	112 W 5TH ST	90013	9	129A211   155	5149037010	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			04/01/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.04687	-118.24902	New fire alarm panel to be installed on grade level in lobby.  All other devices and wiring are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48647	14041-20000-29161	11911 W SAN VICENTE BLVD 150	90049	11	129B145    78	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	ADDRESS	34.05295	-118.47002	PLAN CHECK FOR TITLE 24 ENERGY, RETAIL, NO CHANGE IN OCCUPANCY, 1982 SQFT, EMERGENCY LIGHTING EXISTING TO REMAIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48648	11041-20000-05913	21515 W DEVONSHIRE ST	91311	12	204B105   174	2722007104	P-1, R3-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.12	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Approved	04/05/2011 12:00:00 AM	ADDRESS	34.2574	-118.59902	T.I. to existing restuarant.  Install general/emergency lighting in restroom, corridor, and kitchen area.  Plan check for energy only.Note: Permit issued under 11041-10000-02751	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48649	15041-20000-35105	1000 S WESTWOOD BLVD	90024	5	135B153   617	4363020006	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.06224	-118.44512	Full plan check for power and energy T.I. retail store. Total area: 5,151 sqft. Total load exceed 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48650	10041-10000-00459	7060 W HOLLYWOOD BLVD	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM			PC Info Complete	01/11/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	Title 24 emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48651	12041-10000-08974	13351 W RIVERSIDE DR	91423	2	168B157   293	2359019008	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.15778	-118.42452	Title 24 only , replace 11 lights at Starbucks	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48652	15041-10000-39388	20916 S DALTON AVE	90501	15	051B193    29	7349006022	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.83932	-118.30266	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(42) SILEV MODULES(2) ABB INVERTERS 6/4.2 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48653	18041-10000-03959	5864 S VERMONT AVE	90044		105B197    99	6004001024							Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	33.98758	-118.29131	PC for T24 only. Application fees covered under 18041-10000-03953. B# 18016-70000-02972.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48654	11041-20001-03800	5601 N DE SOTO AVE 2nd floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.17126	-118.58861	Changes from previously approved plans.  Relocate four fire smoke dampers.  All changes are clouded and indicated by DELTA-1 as shown on plans.*****Plan check power. T.I. for Kaiser Foundation structure systems upgrade for ambulatory care facilities.  Install subpanels, branch circuits in the emergency system.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48655	14041-10000-32390	9925 N CANOGA AVE	91311	12	201B105    47	2747010036	[Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.25072	-118.59747	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH  NEW LED FIXTURES. TOTAL AREA 2136SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48656	10041-10000-06875	19901 W NORDHOFF ST	91324	12	195B113    15	2782037034	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03, 1134.01	Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Closed	01/30/2012 12:00:00 AM	ADDRESS	34.23201	-118.56708	Replace failed bus duct anf upgrade existing switchboard to 100KAIC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48657	18041-10003-09952	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.12626	-118.21412	SUPPLEMENTAL FOR CHANGES TO APPROVED SET, LIGHTING FIXTURE CHANGE AND T24 UPDATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48658	10041-10000-05583	700 N FAIRFAX AVE	90046	5	141B177   515	5527011005	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	08/10/2010 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	34.0841	-118.36119	REVISION TO APPROVED PLANS. METHANE BUFFER ZONE.  EPC FOR POWER AND ENERGY OF ONE STORY RETAIL BUILDING I.  METHANE MITIGATION REPORT WAS PROVIDED. NEW SERVICE, PANELS, CKTS, & T24. ORIGINAL PLAN CHECK #08041-10000-07840	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48659	19041-20000-51026	5854 N TAMPA AVE	91356	3	177B117   821	2156004032	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.17735	-118.55326	PV1.  Install 13.5 kW roof mounted PV system with 9.8 kWh energy storage system.  (37) modules with 3.8 and 7.6 kW rated inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48660	17041-20001-39836	10330 W ROCHESTER AVE	90024	5	135B157   403	4327015002	R1V3-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.06412	-118.42492	expeditepv1install roof mounted pv system sized 13.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48661	18041-10000-28646	8321 N DE CELIS PL	91343	12	192B137   289	2689011027	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Closed	09/20/2018 12:00:00 AM	ADDRESS	34.22126	-118.49609	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48662	15041-10000-40760	12815 W VICTORY BLVD	91606	2	180B161  1047	2325032003	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.18684	-118.41231	NEW FIRE ALARM SYSTEM FOR EXISTING COMMERCIAL BUILDING. 69 DEVICES AND 1 FIRE ALARM CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48663	15041-20000-32749	1622 W 7TH ST	90017	1	132A205   345	5142016009	C2-2	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Expired	11/22/2017 12:00:00 AM	PIN	34.05412662	-118.27207044	pv2 commercial rooftop pv. total of 2 inverters and 54 modules. nonstandard plan. interconnected to existing service. may be multi meter bank 20kw	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48664	19041-10000-19049	3000 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	07/05/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.02726	-118.42829	T-24, PC ENERGY ONLY FOR TI  3133 SQ FT OF EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48665	18041-10000-15523	1132 N GLENDALE BLVD	90026	13	139-5A207 157	5404016020	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	34.07702	-118.26071	TENANT IMPROVEMENTS TO EXISTING SHELL SPACE. CHANGE OF USE FROM STORAGE TO OFFICES & CHRUCH ASSEMBLY AREA. FULL PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT # 18014-10000-02760	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48666	15041-20000-23149	19532 W GIFFORD ST	91335	3	186B117  1012	2116020015	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.20491	-118.55886	Installation of new roof mounted solar PV array.  Total system size = 7.9 kWac.  Two inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48667	15041-20002-29516	21217 W DE LA GUERRA ST	91364	3	171B105   532	2167004006	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.16479	-118.59505	10-06-2015 Change to approved set of plans. Changes include addition of solar modules, additional 4 modules , 4 optimizers and inverter size increase to 6.0kW to the system. Total modules: 29  and 29 optimizers[[[[[Plan check for PV roof mounted system in multi-family complex. System size: 5.0kW with 25 modules and 1 inverter(5.0kW)]]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48668	19041-20000-46727	22914 W CALVERT ST	91367	3	177B097   406	2039015014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.18086	-118.62589	PV1.  Install 22.08 kW DC roof mounted grid tied PV system.  (69) modules with (2) 7.6 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48669	17041-20000-29311	7409 N WISCASSET DR	91304	12	186B085   151	2017036004	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.20686	-118.66044	"""0$ permit fees due to senate bill 1222""Plan check a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (47) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48670	13041-10001-29400	4941 E MONTE VISTA ST	90042	1	150A225    43	5467031008	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.1069	-118.20434	Expedited RSES plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48671	15041-30000-37296	17550 W BURBANK BLVD	91316	5	174B129   852	2254037017	R3-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.17209	-118.51591	$0 FEE PER SENATE BILL 1222.Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 43 kWac.  System consists of 3 11 kWac inverters and 1 10 kWac inverter with 50 modules each.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48672	15041-10000-19567	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM			PC Info Complete	06/22/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 3373.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48673	10041-30000-08442	10100 W SANTA MONICA BLVD suite 1050	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	09/27/2010 12:00:00 AM	ADDRESS	34.06191	-118.41691	Installing additional lighting in office area. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48674	19041-10000-44906	5055 N AMESTOY AVE	91316	5	171B133   644	2258011020	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.16198	-118.50557	[EPLAN] PLAN CHECK FOR ENERGY STORAGE SYSTEM(TESLA POWER WALL) CONNECTED TO EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48675	13041-10000-01667	455 E 3RD ST	90012	14	129A215   242	5161020005	R5-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	01/22/2013 12:00:00 AM	PIN	34.04712471	-118.24102236	renovating rest rooms in multipurpose room of a mixed used high riseplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48676	12041-20001-27476	8743 W HOLLYWOOD HILLS ROAD	90046	4	153B169   644	5564012026	RE15-1	Central, West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	1943.00, 2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2013 12:00:00 AM			PC Approved	03/11/2013 12:00:00 AM	ADDRESS	34.11339	-118.38579	Changes to approved set of plans. Re-routing of AC conductors from inverter and change to mounting location of inverter. 5.0kW Inverter.Photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48677	17041-30000-21709	2049 S CENTURY PARK EAST Suite 1400	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is the 14th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 12,670 sq. ft.Note: Building application has been generated under 17016-10000-16566	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48678	16041-10000-01810	4371 E VALLEY BLVD	90032	14	135A229    71	5215014001	[Q]CM-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.06339	-118.19021	$0 final fee per senate bill 1222.PV2, rooftop solar insrallation 86.4 kW AC system(296) RENASOLA JC310M-24(6) SE14.4KUS(1) 300A subpanel no fees due to senate bill 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48679	10041-10000-25862	1114 S GRAND AVE	90015	14	126A207    49	5139020016	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			Reviewed by Supervisor	03/14/2011 12:00:00 AM	ADDRESS	34.04103	-118.26224	NEW 6 STIRIES MIXED USED BUILDING. 1 LEVEL OF COMMERCIAL/RETAIL PLUS 5 LEVELS OF PARKING ABOVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48680	14041-20000-15620	6957 N ALDEA AVE	91406	6	183B133   583	2230001024	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.19715	-118.5085	New roof mounted PV system with 300W optimizer and transformerless 3.8KW inverter.  Total system size 5.1KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48681	19041-10000-43874	2515 N CREST VIEW DR	90046	4	153B169   161	5564032041	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.11767	-118.39055	[EPLAN] PV1 NEW ROOF-TOP SOLAR INSTALLATION 7.6 KWac (10.05KWdc) USING 30 LG LG335NIC-VS  MODULES, 1 SOALREDGE SE7600H-US INVERTER & 30 SOLAREDGE P320 POWER OPTIMIZERS. CONNECTED TO A 225 AMP NEW SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48682	10041-10000-10300	3660 W WILSHIRE BLVD	90010	10	132B193    63	5093019020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			06/01/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.06155	-118.30505	Ti in an existing office building. Plan check for Energy & T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48683	17041-10001-22111	9046 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.23442	-118.55336	PC FOR CHANGES TO APPROVED SET UNDER DELTA 6 SCOPE INCLUDES CHANGING A FIXTURE TYPE TO REFLECT FIELD INSTALLATION AND REVISION TO T-24 FORMS TO REFLECT NEW FIXTURE. THIS IS PLAN CHECK ONLY!PLAN CHECK FOR T24 ONLY FOR TI (INTERIOR TI FOR CHANGE FROM EXISTING RESTAURANT TO BAKERY. TOTAL AFFECTED AREA = 3925SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48684	17041-10000-08106	20931 W NORDHOFF ST	91311	12	198B109   168	2746009026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.23563	-118.58992	T24 ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES 28175 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48685	17041-10000-12290	11737 W WICKS ST	91352	6	198B169   106	2538002039	M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Info Complete	09/06/2018 12:00:00 AM	ADDRESS	34.23802	-118.38857	PC for power only. Replacing (2) existing 3-phase 400-Amp 120/240v with (2) 3-phase 600-Amp 277/480v services. The (2) 400Amp board is being reused as distribution board for all existing load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48686	16041-10000-36727	1042 W PRINCETON DR SUIT B	90292	11	105B149   499	4229003049	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	33.98606	-118.44621	PC FOR TITLE 24. ENERGY ONLY. SCOPE INCLUDES NEW LIGHT AND RECEPTACLES.TOTAL AFFECTED AREA 2885 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48687	15041-20002-10592	3479 N CAHUENGA BLVD	90068	4	159B177   338	2425024028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.13249	-118.35498	pc for chnages to approved set of plans. addition of more lighitng fixtures. rechecking all lighitng. permit already issued	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48688	17041-10000-28796	10334 N ORO VISTA AVE	91040	7	204B189   392	2560013007	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.25711	-118.31562	PC FOR ROOF MOUNTED PV ON SLD SYSTEM SIZE 3.0KWAC USING CENTRAL INVERTER WITH STORAGE BATTERY. INCLUDING 11 MODULES AND LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48689	13041-10000-04299	1 W WORLD WAY WEST	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Expired	03/17/2015 12:00:00 AM	PIN	33.94461393	-118.39808495	TITLE 24 FOR INTERNALLY ILLUMINATED STORE SIGN FOR SUNGLASS HAT IN LAX TERMINAL 4 SPACE 42.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48690	13041-10000-01822	1600 N VINE ST	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.1	-118.32647	T24 for 6th floor. 1197 sqrft. for leasing offices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48691	11041-20000-00849	745 W ADAMS BLVD	90007	1	123A203   178	5124025001	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	01/18/2011 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.02985	-118.27941	new fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48692	18041-10000-32733	2400 S LINCOLN BLVD	90291	11	108B149   487	4236001020	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.99401	-118.45221	Plan check for Power only. New 200A, 480/277V 3phase 4-wire service  with (2) level 3 EVCS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48693	13041-10002-08845	621 W 152ND ST	90247	15	072B201    75	6120001017	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	33.89472	-118.28668	ADDITION OF TWO PANELBOARDS TO SERVE NEW MOTOR OPERATED EQUIPMENTADDING NEW FEEDERS TO EXISTING SYSTEM FOR CALIFORNIA WASTE MANAGEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48694	19041-10000-36919	1922 N HILLHURST AVE	90027	4	150B201   908	5590011006	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	05/18/2022 12:00:00 AM	ADDRESS	34.1061	-118.28725	FULL PC FOR A NEW 2 STORY BUILDING (MEDICAL OFFICES WITH EXAM ROOMS AND PROCEDURE ROOMS) WITH 3 STORY SUBTERRANEAN PARKING. SCOPE OF WORK INCLUDES A NEW 800A SERVICE (480/277 3P 4W) THAT FEEDS A 800A METERBOARD. WHICH SUBFEEDS TWO ELEVATOR, AN X-RAY MACHINE, AND VARIOUS SUBPANELS. TOTAL AFFECTED AREA IS 48,288B#19010-10000-02142	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48695	16041-10000-36494	10910 S LOU-DILLON AVE	90059	15	088-5A215 242	6068004018	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	33.93683	-118.23473	PV, INSTALL 7.95 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(30)  MODULES: KYOCERA KU2656ZPA(1) INVERTER: FRONIUS IG PLUSA 7.5	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48696	19041-10000-05124	111 N PIER S AVE	90731	15	024B213    77	7440012805	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM			Reviewed by Supervisor	02/20/2019 12:00:00 AM	ADDRESS	33.75884	-118.24168	PC FOR NEW ELECTRICAL SERVICE FOR (E) LONG BEACH HARBOR COMMERCIAL RUBBLE CRUSHING SITE, INSTALLATION OF (1) 2000A SERVICE, (1) 2000A PANEL BOARD, (1) 30KVA XFMR, (1) 75KVA XFMR, (1) 200A PANEL, AND (1) 100A PANEL.NOTE: INCLUDES INSTALLATION OF 1/2 MILE OF DUCT BANKS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48697	19041-30000-25438	2029 S CENTURY PARK EAST 30TH FL	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	07/13/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	ENERGY PC FOR T. I. RENOVATION TO PUBLIC RESTROOMS ON THE 30TH FLOOR.  AREA 410SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48698	17041-10000-44078	5249 W CENTURY BLVD	90045	11	090B173    93	4128017044	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM			Verifications in Progress	07/10/2018 12:00:00 AM	ADDRESS	33.94558	-118.37196	******new redesign work under 18041-10000-30005Per inspector request, this is power plan check only, (express) permits have been pulled under 17041-10000-17846 and 17041-20000-08504. Adding circuits for refrigerator and microwave for 254 units at LaQuinta Hotel. Demand load calculation for 12 months is attached.(B# 16016-10000-28180)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48699	16041-10000-18559	7701 N LAUREL CANYON BLVD	91605	2	189B165  1086	2307012022	R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Issued	05/26/2016 12:00:00 AM	ADDRESS	34.2106	-118.39672	PC FOR FA SYSTEM REPLACEMENT AND UPGRADE OF A FEW DEVICES. ADDITION OF DETECTORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48700	12041-10000-00791	1888 S CENTURY PARK EAST	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Info Complete	01/12/2012 12:00:00 AM	ADDRESS	34.06104	-118.41402	Title 24 only, TI 18th floor office space no change in occupancy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48701	13041-20000-15717	7412 N DORIE DR	91304	12	186B089   389	2027024018	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Expired	09/07/2015 12:00:00 AM	PIN	34.20598151	-118.64779811	PV1 PLAN CHECK FOR PV SINGLE FAMILY. 8.2KW SYSTEM. 33 PANELS AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48702	15041-20001-23905	21030 W GRESHAM ST	91304	3	195B105   139	2779003050	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM			Reviewed by Supervisor	08/07/2015 12:00:00 AM	ADDRESS	34.23048	-118.59195	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 46.5 kWac and consists of (186) modules, (186) micro-inverters, and (4) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48703	18041-10000-20723	6206 N SEPULVEDA BLVD	91411	6	177B145   332	2242010014	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.18325	-118.46593	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48704	13041-10000-22043	7600 S AVALON BLVD	90001	9	099B205    94	6023017900	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.02	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	PIN	33.97099935	-118.26484019	PV2. ROOF MOUNTED PHOTOVOLTAIC SYSTEM. 8.637 kW. TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48705	15041-10000-37310	2025 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.05978	-118.20504	New FA to a school building (USC Steven's Hall research building) 5 floors. (1) FA panel, (2) Control Panel, (3) Communication panels, (440) FA devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48706	11041-10000-23858	618-620 S BROADWAY	90014	14	129A211   228	5144002020	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			11/10/2011 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.04607	-118.25233	T.I. for an existing restaurant.  100 New circuits and new equipment.  All AC-units and panels are existing.  Plan Check for POWER and ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48707	19041-20000-27138	11610 N NORRIS AVE	91340	7	213B157   319	2523007009	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.2813	-118.42768	Plan check for a PV1 roof-mounted PV system. System size is 4.41 kWdc/3.8 kWac and consists of (1) inverter and (14) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48708	14041-10000-02820	15801 W MOORPARK ST	91436	5	168B141   508	2261012016	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.15688	-118.47729	Investigation fees to be collected under a different application.PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON TRANSFORMERLESS INVERTERS WITH POWER OPTIMIZER ON A ONE-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) INVERTER: SOLAREDGE SE5000A-US(19) MODULES: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48709	15041-10000-17689	11048 W OLYMPIC BLVD	90064	5	126B153   712	4322017001	R3-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Apartment			06/08/2015 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.04076	-118.43659	Full plan check for a new 4-story, 8-unit apartment; Scope includes a 600-Amp 3-phase 4-wires.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48710	13041-20000-15145	5727 N LANKERSHIM BLVD	91601	2	174B169   484	2338022023	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			Reviewed by Supervisor	06/25/2013 12:00:00 AM	ADDRESS	34.17468	-118.38084	RENOVATION OF EXISTING RESTARAUNT. 600A RATED EQUIPMENT. FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48711	17041-10000-35644	20753 W BLACKHAWK ST	91311	12	204B109   100	2706013001	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.25837	-118.58587	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(24)MODULES-SOLARIA POWERXT 320R-BX(24)OPTIMIZERS-SOLAREDGE OPTIMIZERS P400(1)INVERTER-SOLAREDGE SE7600H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48712	12041-10000-05756	2500 S NAVY WAY	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	33.73363	-118.2408	Plan check for new installation (5) shore to ship power, including 34.5KV and 6.6KV equipment. Methane Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48713	19041-20000-31505	1377 N SERRANO AVE 2nd Floor	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.0965	-118.30717	Power and lighting for commercial office TI on second floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48714	10041-10000-25335	6360 W 3RD ST	90036	4	138B177   796	5509018009	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM			PC Approved	01/03/2011 12:00:00 AM	ADDRESS	34.07122	-118.36074	T-24 Plan Check for exterior canopy lighting and facade.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48715	13041-20001-34353	16007 W LASSEN ST	91343	12	201B141   157	2669024007	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM			Reviewed by Supervisor	12/19/2013 12:00:00 AM	ADDRESS	34.25026	-118.4808	PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING 3 STRINGS TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48716	11041-10000-17316	5076 W SUNSET BLVD	90027	13	147A195   545	5543026034	C2-1D	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	34.09789	-118.3003	T.I.  Existing 7-Eleven.  Replacing the existing light fixtures with LED fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48717	17041-20000-22370	7206-7208 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.24846	-118.2889	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.building application number under 16016-10000-18172	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48718	16041-20000-13677	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	33.78808	-118.29535	Plan check for a PV2 carport PV system. System size is 212 kWac and consists of (8) inverters, (920) modules, and (1) load center.Note: Building application has been created under 16014-20000-01760	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48719	18041-20000-10621	1901 N ECHO PARK AVE	90026	13	142-5A211  34	5420022023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Apartment			03/23/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	11/23/2020 12:00:00 AM	ADDRESS	34.0864	-118.25188	Plan check for power and energy. Project site is a new 4-story, 13-unit apartment building. Work includes an 800-amp service and a total lighting area of 13,205 sq. ft.Note: Building application has been generated under 17010-30000-03242	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48720	16041-20000-15274	3637 N CAHUENGA BLVD	90068	4	159B177   146	2425005045	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.13455	-118.36054	NEW FIRE ALARM SYSTEM FOR SINGLE STORY COMMERCIAL BUILDING.  ADDING (1) FA PANEL AND 37 DEVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48721	18041-10000-15991	15809 W STRATHERN ST	91406	6	189B141    34	2206004004	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.21581	-118.4779	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48722	12041-20000-03476	560 S ST LOUIS ST	90033	14	126A221   109	5183019032	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	ADDRESS	34.03916	-118.21715	energy plan check office	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48723	18041-10001-09695	7426 S ALVERSTONE AVE	90045	11	102B165   621	4110004041	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	33.97388	-118.39697	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 4.20KWdc / 3.92KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER AND A METER ADAPTER. (14)MODULES-SOLARWORLD  SW-300(14)OPTIMIZERS-ENPHASE S280--60-LL-2-USNOTE: SOME FEES ARE COVERED UNDER MASTER PERMIT PCIS#17041-90000-09695	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48724	17041-10000-19990	5615 S MESMER AVE	90230	11	105B165   281	4220006076	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	33.98582	-118.40099	Title 24 plan check.  2nd story addition and change of use from factory/warehouse to new recording studio.  4 new subpanels connected to 2 existing services.  New lighting, receptacles, and HVAC.  Total area = 5,771 sq. ft. All changes under delta 1       Building permit #15016-30000-02405	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48725	14041-10000-14217	505 S VIRGIL AVE #106	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.0649	-118.28724	PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE FROM OFFICE TO DENTAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48726	16041-10000-02204	8463 N AURA AVE	91324	12	192B117   331	2783003014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Expired	02/19/2018 12:00:00 AM	ADDRESS	34.22434	-118.55478	PV1INSTALL ROOF MOUNTED PV SYSTEM ( ADDITION TO AN EXISTING SYSTEM) SIZED 7.6KW INTERCONNECTED WITH MSP.(32) HANWHA QCELLS 260 MODULES(32) OPTIMIZERS(1) SOLAREDGE 7600 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48727	14041-20000-14025	15724 W LEMARSH ST	91343	12	204B141   583	2661018018	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.25539	-118.47483	PV1.  Install 10.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48728	14041-10000-13752	3200 W WILSHIRE BLVD	90010	10	132B197    41	5094008026	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.06163	-118.29212	TITLE 24 PLAN CHECK ONLYTenant improvement for an existing commercial space highrise (bank)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48729	17041-10000-36368	26640 S WESTERN AVE	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	33.78015	-118.30862	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO CHARTER SCHOOL. SCOPE INCLUDESA NEW LIGHTS AND RECEPTACLES FOR OFFICE/RECEPTION/CONFERENCE SPACES. TOTAL AFFECTED AREA IS 7997 SQ. FT.  B#16016-10000-21429PC ONLY PERMIT PULLED UNDER 17041-10000-36335	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48730	13041-20000-04298	6600 N TOPANGA CANYON BLVD #1065A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Change to lighting in a Beauty Salon.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48731	19041-20000-00985	9764 N ABREGO CT LOT 9	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.2478	-118.45053	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48732	12041-10000-25434	21031 W WARNER CENTER LANE	91367	3	174B105    24	2149017007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.17501	-118.59119	Plan check T24 Energy/emergency lighting for corridor on the 1st floor. Permit for new branch circuit and lighting on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48733	19041-10000-31822	1250 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	08/01/2020 12:00:00 AM	ADDRESS	34.02528	-118.29315	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48734	16041-20000-02422	2700 N VERMONT AVE	90027	4	153B193   686	5593002913	OS-1XL	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.11803	-118.29221	Plan check for Title 24 only for Greek Theatre T.I in dressing rooms and corridor. Total area: 6,488 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48735	17041-10000-06602	100 S BARRINGTON WALK	90049	11	135B145   554	4401006004	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.06541	-118.46942	T-24, PC FOR ENEGY ONLY. T.I TO AN EXISTING 2nd floor office. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 583 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48736	19041-20000-21955	19350 W NORDHOFF WAY #F	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.23523	-118.55518	New 600A feeder and tenant space disconnect for future TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48737	16041-20000-02885	7900 N BALBOA BLVD BLDG 'G'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.21347	-118.50092	Plan check for power and energy Aircraft Hangar Building 'G' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' G' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48738	14041-20000-15487	8807 N SOPHIA AVE	91343	12	195B137   602	2688037031	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.23053	-118.4885	PV1.  Install 4.59 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48739	15041-10000-11525	3065-3079 N SAN FERNANDO ROAD	90065	13	153A213    91	5458009018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	PIN	34.11441394	-118.24493975	PC for power and energy.new service for ti,for a new tenant space, since the design changed completely the additional fees added to the fees.original app# 13041-10000-34099,plan check only.<<<STOREFRONT REMODEL TO EXISTING 3-RETAIL TENANT SPACES TO CREATE TOTAL OF 6-RETAIL TENANT STORES (SHELL ONLY).  POWER AND ENERGY.  LOADS ON (E) PANELS ARE EXISTING TO REMAIN PER APPLICANT.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48740	14041-20000-11209	5367 N WINNETKA AVE	91364	3	171B113    69	2166006007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.16778	-118.5711	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.25KW INTERCONNECT WITH MAIN PANEL.(1) TRANSFORMERLESS INVERTERS;  SOLAR EDGE SE6000 WITH OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48741	16041-10000-29898	2001 S VERMONT AVE	90007	1	126B197  1027	5075040001	[Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.03796	-118.29176	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 7752 SQ FT. (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48742	16041-10000-26737	888 S FIGUEROA ST STE#1700	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.0465	-118.26225	T-24, PC FOR ENERGY ONLY TI TO AN EXISTING HIGH RISE BUILDING ON THE 17TH FLOOR. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 4278 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48743	16041-20001-21203	10349 W DIAMOND ST LOT 7	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48744	10041-20000-12115	2788 S MONTE MAR TER	90064	5	126B165   493	4308015010	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.04205	-118.40072	Plan check for new installation of 13.8KW Photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48745	15041-20001-44018	13206 N CRANSTON AVE	91342	7	225B161    79	2512024046	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	ADDRESS	34.31163	-118.41753	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (12) micro-inverters and (12) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48746	19041-10000-17301	430 W PICO BLVD	90015	14	126A207   169	5134017032	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM			PC Info Complete	05/29/2019 12:00:00 AM	ADDRESS	34.03916	-118.26536	PC FOR ENERGY ONLY CHANGE OF USE RETAIL TO GYMNASIUM. AREA SCOPE OF WORK 1370 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48747	13041-10000-22806	10900 N JAMIE AVE	91331	7	210B165   532	2536021011	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.26808	-118.40439	PV1-ROOF MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 7.35KW DC, TRANSFORMERLESS WITH:30 MODULES-  TRINA SOLAR TSM-245PC05/PA05.18(2) 3.8 KW AC - SOLAREDGE # SE3800A-USPOWER OPTIMIZER: SOLAREDGE # OP250-LV-MC4SM-2NA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48748	14041-10001-05703	12418 W HAVELOCK AVE	90066	11	105B161   127	4221023024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	33.98737	-118.41742	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(15) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48749	19041-10000-46809	707 W WILSHIRE BLVD 33RD FLR	90017	14	129A209    50	5144005400	C2-4D, [Q]M3-1	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.04893	-118.2572	T-24 PC ONLY. SCOPE INCLUDES INSTALLATION OF NEW LIGHTING FIXTURES. NO NEW CKTS. AFFECTED AREA 1012sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48750	16041-20003-30272	18903 W RINGLING ST	91356	3	171B121   498	2176010009	RA-1	South Valley	Encino - Tarzana	Tarzana		1398.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	PIN	34.16229368	-118.54458786	Revisions to approved set of plans.  Change of module type and equipment layout to reflect existing conditions.  Change to equipment AIC ratings to reflect existing 320A meter switch amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48751	14041-10000-08018	3244 S GREENFIELD AVE	90034	5	120B157   481	4251022020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.02533	-118.42145	PV1. ROOF MOUNTED SOLAR SYSTEM. STANDARD TRANSFORMER INVERTER. SYSTEM SIZE: 7.02 KW DC. ( 27 ) REC SOLAR REC260 PE MODULES(1) POWER ONE PV1 6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48752	15041-20000-10713	6906 N CALVIN AVE	91335	3	183B117   815	2130019023	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.19579	-118.55535	Plan check for a PV1 roof-mounted PV system. System size is 3.4 kWac and consists of (16) modules and (16) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48753	14041-20000-08731	7251 N CHICOPEE AVE	91406	6	186B129  1180	2228013017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.20282	-118.51253	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. SYSTEM SIZE : 2.5 KW DC(10) CANADIAL SOLAR CS6P-250(1) SOLAR EDGE # SE3000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48754	16041-10000-19732	5900 W WILSHIRE BLVD 6TH & 11TH	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.06237	-118.35809	TITLE 24 FOR COMMERCIAL BUILDING 708 SQ. FT. LIGHTING ON 6TH FLOOR. ADDING 2 OUTLETS ON THE 11TH FLOOR WITH NO LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48755	15041-20001-25051	16940 W KNOLLWOOD DR	91344	12	216B133   401	2610001002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	34.28761	-118.50039	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.3 kWac and consists of (2) inverters, (36) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48756	10041-10001-01790	1129 E 5TH ST	90013	14	127-5A215 401	5163025009	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM			PC Approved	08/17/2010 12:00:00 AM	PIN	34.04171033	-118.23706491	Change to previously approved set plans. Change the quantity of inverters and strings. Plan check for PV system. ((((((((((((((((((INSTALLATION OF A 10.00 KW PHOTOVOLTAIC SYSTEM.  54 modules installed on the roof of the building.)))))))))))))))))  Existing permit 10041-10000-01790.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48757	14041-20000-11203	6454 N BAIRD AVE	91335	3	180B125   568	2127010004	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.18828	-118.53745	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 7.5kW(2) SolarEdge #SE3800A-US-ZB-U transformerless inverters(30) Canadian Solar #CS6P-250PX pv modules(30) SolarEdge #P300-2NA4AZS power optimizers(1) Bryant #BR816L125RP 125Amp load center(3) New branch circuits	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48758	18041-10000-49196	261 S FIGUEROA ST SUITE 200	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	12/31/2018 12:00:00 AM		Issued	12/31/2018 12:00:00 AM	ADDRESS	34.05546	-118.25446	DESIGN BUILD. Energy plan check for an office T.I, Scope includes new lighting and receptacles with a total area of 1546-SQ FT. bld # 18016-10000-14957	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48759	14041-10000-22290	13361 N GLENOAKS BLVD BLDG A	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.3146	-118.45921	Installation of fire alarm system in new charter school (plans cover bldg A, B and C - 14041-10000-22290 AND 32331 AND 32334 RESPECTIVELY).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48760	14041-10000-17495	2029 S CENTURY PARK EAST SUITE 3150	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Not Ready to Issue	08/07/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	TITLE 24 PLAN CHECK FOR OFFICE BUILDING. HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48761	14041-20000-14770	3138 W PICO BLVD	90019	10	129B193  1332	5073008001	C2-1VL	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.04701	-118.31048	New 1600A service for a commercial building for future tenants.  Plan check for future tenants to be required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48762	19041-10000-33577	10231 W WOODBINE ST	90034	5	120B161   104	4314023024	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	01/05/2021 12:00:00 AM	ADDRESS	34.02858	-118.40809	PLAN CHECK FOR A FIRE ALARM SYSTEM IN A 4 STORY, 9 UNIT MULTI-FAMILY DWELLING. SCOPE INCLUDES NEW FA PANEL, COMMUNICATOR, ANNUNCIATOR AND 61 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48763	15041-20001-18877	11315 N GOTHIC AVE	91344	12	210B137    19	2681013029	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2015 12:00:00 AM			PC Approved	06/20/2015 12:00:00 AM	ADDRESS	34.27619	-118.48923	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 125A MSP w/100A main disco.System size: 7.6kW. Ungrounded system. Using 400W power optimizers on each of the (32) 315W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48764	10041-10000-13218	4235 S REDWOOD AVE	90292	11	108B153  1232	4230006026	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM			PC Info Complete	07/12/2010 12:00:00 AM	PIN	33.9885825	-118.43893002	T.I in office and studio title 24 only.  permot is based on the number of units since no new circuits is added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48765	19041-20000-41912	6624 W MELROSE AVE	90038	5	141B185   613	5524017020	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Info Complete	10/15/2019 12:00:00 AM	ADDRESS	34.08331	-118.33948	TI to (E) office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48766	18041-10000-13265	1999 S AVENUE OF THE STARS 15TH FLR	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PC for T24 only for new lighting for 15th floor TI in high rise building. Installing new lights and receptacles in common areas and restrooms. Total area is 1931 sqft. B#18016-10000-06405.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48767	13041-20001-35611	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.08363	-118.32191	Alteration to approved set of plans. Re-checked for minor changes to lighting plan/design. [[[PC FOR T24 ENERGY ONLY. NEW LIGHITNS EXISTING STUDIO]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48768	14041-10001-32182	7450 N WISCASSET DR	91307	12	186B085   157	2017036018	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM			Verifications in Progress	03/03/2015 12:00:00 AM	PIN	34.20786502	-118.65907977	Expedited plan check per applicant request.  PV1.  Install 8.8 kW DC ground-mounted, utility-interactive PV system.  Enphase M250 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48769	16041-20001-36167	2441 S SEPULVEDA BLVD 1-595	90064	5	123B153   141	4256010006	(T)(Q)C2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM	ADDRESS	34.0358	-118.43461	[[[ RESUBMITTAL OF MAJOR DESIGN CHANGES TO SINGLE LINE DIAGARAM. 4160V SERVICE AND DISTRIBUTION. CORE AND SHELL ONLY PLANS , (MASTER PERMIT UNDER 16041-20000-36167)]]New 13-story (5 stories subterranean parking), 595-unit residential highrise with 1200A 4160V service.  Plan check for power and energy.  Building permit filed under 16010-10000-01422Fees adjusted to meet applicant check amount.  Plan checker to verify fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48770	14041-20000-33926	6344 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/08/2014 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	TI TO A RETAIL COMMERCIAL SPACE  [ BASSETT WOODLAND HILLS FURNITURE STORE] TWO STORY (WESTFIELD) .  FIRST TIME TENANT. NEW PANELS, TRANSFORMERS, CIRCUITS, LIGHTING. PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 14,681.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48771	17041-20001-33180	6540 W SUNSET BLVD	90028	13	147A187   165	5547026024	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.09782	-118.33292	12.4.2017 - Plan check for modifications to approved set. Changes clouded delta 2. Update lighting control system. Revise lighting design - update T24 forms and fixture schedule. Change exit signs to self-illuminating.======PC FOR OFFICE TI IN (E) A TWO STORY BLDG. TOTAL CONNECTED LOAD <400A  TOTAL AFFECTED AREA 6696 SQ.FTSCOPE INCLUDES NEW PANELS, CIRCUITS, LIGHTS AND EQUIPMEMNT. B#17016-20000-09488	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48772	18041-20001-44551	5161 N AMESTOY AVE	91316	5	171B133   350	2258008024	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.16454	-118.50558	(Expdite per applicant request)Plan check for 13.32KW PV solar rooftop w/37 ACM modules. connected to 400A main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48773	16041-10000-33669	14000 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Issued	10/04/2016 12:00:00 AM	ADDRESS	34.15735	-118.43783	Full PC FOR POWER AND ENERGY, PC for an existing Lenscrafters inside existing Macy's Department store. Scope includes new lights and receptacles. Total affected area is 1106 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48774	10041-20000-16640	3300 W TEMPLE ST	90026	13	139-5A201 235	5156003030	C2-1	Central	Westlake	Rampart Village	YES	2086.10	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.07554	-118.28238	New 2-story with 18 units appartment building over framed basement garage.  Building in methane zone with level II.  Plan check for power and energy.NOTE:A variance for separate fire alarm system has been file.  Fire alarm and methane gas detection systems are on separate plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48775	13041-20000-33633	19343 W OLIVOS DR	91356	3	168B117   173	2175006012	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/16/2014 12:00:00 AM	ADDRESS	34.15824	-118.55462	New rooftop PV system for an existing sfr.   System uses Solar Edge Power Optimizers.  (($0.00 Permit fee per law.))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48776	13041-10000-35152	1801 E 45TH ST BLDG E	90058	9	112-5A213 138	5106005033	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.00291	-118.24112	"T24 PART 6 ENERGY FOR (E) 17720 SQ FT COMMERCIAL SPACE BUILDING ""E"".  RETRO-FITTING 4' FLUORESCENT LIGHT FIXTURES WITH NEW F54T5HO LAMPS ONLY.  SCOPE OF WORK < 400A.  PERMIT IS EXISTING UNDER 11041-10001-21647.  NO NEW/MOVED WIRING PER APPLICANT, INSTALLATION NOT SUBJECT TO LIGHTING CONTROL REQUIREMENTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48777	18041-30000-37576	13670 W SHERMAN WAY	91405	2	183B157    70	2328008028	C1-1VL, P-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			Reviewed by Supervisor	10/12/2018 12:00:00 AM	ADDRESS	34.20091	-118.43098	Full plan check for Power and Energey for New CVS pharmacy.  New 1200A, 120/208V service, (3)New subpanels, new motor loads, and new ligting loads. Total area: 15,182 sq.ft(B# 18010-30000-04724)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48778	19041-10000-10377	11750 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	05/17/2022 12:00:00 AM	ADDRESS	34.04843	-118.4618	PLAN CHECK FOR POWER AND ENERGY FOR NEW 5000A SERVICE 480/277 WITH ASSOCIATED DISTRIBUTION EQUIPMENT AND 100KW GENERATOR. TOTAL AFFECTED AREA 417,000 Sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48779	19041-20000-01010	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.04538	-118.26335	Renovation to (E) 5-story commercial building elevator lobbies from first floor mezzanine to fifth floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48780	18041-10000-26433	1912 E CESAR E CHAVEZ AVE Unit A	90033	14	130-5A221 346	5174006060	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.04974	-118.21482	"T-24, PC for energy only. Change of use from office to retail. Scope includes new lights and receptacles. Total affected area is 1045 SQ. FT. B#18016-10000-20263 Investigation fee paid under building permit""COMPLY WITH DEPARTMENT ORDER effective date05/11/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48781	18041-10000-29964	19700 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	33.85221	-118.2903	PC FOR T-24 FOR REMODEL FOR LOBBY AND AMENITY SPACE ON FIRST FLOOR AND RESTROOMS ON SECOND FLOOR. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS.TOTAL AFFECTED AREA 8442 SQ.FT. (INDOOR +OUTDOORS).B# 18016-10000-25409	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48782	12041-20000-04176	18232 W KINZIE ST	91325	12	201B125   231	2764018006	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	05/21/2012 12:00:00 AM	ADDRESS	34.24807	-118.53088	3.06 KWdc pv system single family microinvereter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48783	10041-10003-12250	6280 W HOLLYWOOD BLVD	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/02/2011 12:00:00 AM			PC Approved	02/02/2011 12:00:00 AM	ADDRESS	34.10146	-118.32615	REVISIONS TO SINGLE LINE DIAGRAM TO SHOW TEMPORARY USE OF EXISTING  120/240V 3PH 3W SERVICE  UNTIL DWP CAN PROVIDE SERVICE AS SHOWN ON THE ORIGINAL DIAGRAMTi for a new restaurant. Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48784	16041-10004-12519			13	138B197    84	5501001023	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	PIN	34.07744456	-118.28982959	02/16/2017 Changes to an approved set of plan. Changes include adding AC disconnect Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48785	18041-10000-21975	2049 S CENTURY PARK EAST 13 Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN EXISTING RESTROOMS ON THE 13TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48786	19041-10000-30819	3022 N COOLIDGE AVE	90039	13	150B213   886	5442022020	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	12/21/2021 12:00:00 AM				PLAN CHECK FOR 800 AMP NEW SERVICE AND PANELS FOR 30 SMALL LOT SUBDIVISION SINGLE FAMILY DWELINGS. (3 OF 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48787	13041-10000-17666	951 W FLORENCE AVE	90044	8	102B197  1112	6013001029	[Q]C2-1VL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.97479	-118.2909	PLAN CHECK FOR POWER AND ENERGY FOR A NEW CAR WASH WITH A 600 A SERVICE. NEW PANEL AND ASSOCIATED LOADS, NEW VACUUM, NEW WATER PUMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48788	14041-10000-16978	1925 S CENTURY PARK EAST SUITE #400	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Issued	07/10/2014 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. SUITE #400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48789	16041-10000-42974	201 N FIGUEROA ST 8th Floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 8TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5622 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48790	09041-20001-08354	6100 N WOODLEY AVE Building 3	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.18088	-118.48309	as built drawings by sinspection delta 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48791	18041-20000-31876	11500 N SEPULVEDA BLVD	91345	7	213B145     9	2664006***	A2-1, RE20-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM			PC Info Complete	09/07/2018 12:00:00 AM	ADDRESS	34.27935	-118.46865	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,396 sq. ft.Note: Building application has been generated under 18016-10000-26770	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48792	14041-10000-05111	555 W 5TH ST SUITE 3300	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.05016	-118.25369	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 33RD FLOOR SUITE 3300. OFFICES. NO CHANGE IN OCCUPANCY.  < 400 AMPS NEWLY CONNECTED LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48793	17041-10000-11672	5950 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Approved	04/11/2017 12:00:00 AM	ADDRESS	33.94286	-118.38591	PC for relocated motor , controller and shut off for a reloacated propane tank in a hazardous location. Installing new conduits with seal -offs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48794	15041-20000-02651	8630 N NOBLE AVE	91343	6	195B145   589	2653010067	R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.22716	-118.46099	Roof mounted PV system with total system size 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48795	19041-10000-07388	5500 W 98TH ST Temp Power	90045	11	093B173   581	4128022906	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/08/2022 12:00:00 AM	ADDRESS	33.94764	-118.37749	Medium voltage temp powwer for a 5-story parking located in LAX airport. Scope includes a 3-section 5KV suppying a 5KV, 2000KVA tranformer connecting to a 3000AMP 277/480V distribution panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48796	11041-10002-10748	1900 S SEPULVEDA BLVD	90025	5	126B153   181	4323022031	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.04447	-118.4413	REVISIONS TO PERMITTED SET OF PLANS:ATTACHED TO THE PLANS ARE THE LISTS OF CHANGES MADE ; NEW CIRCUITS AND CHANGING PNL LP3A FROM 84 CKTS TO 126CKTS PANEL AND PANEL LP3B FROM 42CKTS TO 84 CKTS PANELExisting shell building 3 stories tall with 3 story parking garage.  Everything is new.  DWP is demo-ing existing 1000 amp service and putting in two 1000 amp services.  Applicant has submitted variance to have 2 services installed.  All wiring is new.  Everything to be considered new.  Also, applicant has submitted the architectural and demo plans for reference.  Applicant has also submitted plans for a fire alarm under a different application.  Regular plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48797	10041-20000-13338	8226-8244 N VAN NUYS BLVD #8226-8244	91402	6	192B149   446	2212004033	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	09/01/2010 12:00:00 AM	ADDRESS	34.22058	-118.44858	Plan check T-24 Energy (general/emergency) lighting from one existing retail to three retail space. This plan check is for addresses #8226 & #8240. Address #8244 will on seperate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48798	13041-20001-14831	2453 S PATRICIA AVE PV 1	90064	5	126B161    18	4318005027	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.04382	-118.41808	Plan check only. Permit on master application. Return to plan check due to discovery of combiner box.ROOF MOUNTED PV SOLAR SYSTEM 9.9 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48799	14041-20000-10669	6700 W SANTA MONICA BLVD	90038	4	144B185   780	5532026023	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.09055	-118.33652	TI in (E) 2-story commercial office building to existing restrooms on both floors.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48800	13041-10000-36065	741 E PICO BLVD	90021	14	123A211    71	5132012055	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.03226	-118.25258	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 683 SQ FT. REPLACING TOTAL OF 1 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48801	14041-20001-01489	16220 W ARMSTEAD ST	91344	12	213B141    42	2605019022	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.28279	-118.48536	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 5KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48802	16041-10001-37785	300 S FERRY ST PV	90731	15	018B205    66	7440023***	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	33.74748	-118.26198	EXPEDITED PER APPLICANT REQUEST ************************************************************************************PC FOR PV FEED IN TARRIF (FIT) . SYSTEM SIZE 645KW.DC  581KW.AC SCOPE INCLUDES TOTAL OF 1199 MOUDULES AND 7 INVERTERS (83KVA).WITH NEW DEDICATED SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48803	17041-20000-00983	11826 W SHELDON ST	91352	6	198B169    54	2538003030	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.24137	-118.39062	service upgrade 1600amp feeding (2) 800 amp sections.  loads to be future. plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48804	19041-20000-12669	11124 N AMESTOY AVE	91344	12	210B133   400	2697024020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.27284	-118.50632	Installation of 13.5 kWh energy storage system and associated distribution equipment/critical backup panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48805	15041-20000-35268	11250 N EL DORADO AVE	91331	7	210B153   269	2616021061	R1-1, [T][Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	PIN	34.27431215	-118.43382956	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING CENTRAL INVERTER SYSTEM. USING NONSTANDARD PLAN. TOTAL OF 16 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48806	17041-10001-04836	6329 S DENVER AVE	90044	8	105B201  1234	6004020014	R2-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	33.98157	-118.2839	02-22-2017 Changes to an approved set of plans. Changes include update Single line diagram to 2 meters Service. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48807	19041-20000-07454	1640 E MARENGO ST 2ND FL	90033	14	133-5A223  37	5201001001	C4-1-CUGU, P-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2033.00	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.05983	-118.21397	T24 PLAN CHECKFOR SUITE A 200 CORRIDOR OF EXISTING COMMERCIAL BUILDING, TOTAL SQUARE FOOTAGE = 1353 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48808	17041-20000-30035	19254 W LANARK ST	91335	3	189B117   160	2104003001	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.21733	-118.55313	Plan check for solar pv system, roof-mounted on SFD. Line-side tap interconnection.11.4kW ungrounded system. (48) 275W pv modules.Each module has a 320W power optimizer.$9.21 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48809	18041-10000-29667	8303 W MELROSE AVE	90069	5	141B173   427	5528003001	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	05/01/2021 12:00:00 AM	ADDRESS	34.08387	-118.37057	PLAN CHECK FOR POWER AND ENERGY FOR - CORE AND SHELL FOR A NEW 2 STORY OFFICE  SPACES WITH STACKED PARKING SPACES IN REAR (5391 SF) NEW SERVICE RATED AT 800A, TOTAL AFFECTED AREA = 2806 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48810	13041-10000-10880	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			04/26/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.06188	-118.30486	RENOVATION OF EXISTING KITCHEN SPACE. PC FOR ENERGY ONLY, T24. TOTAL AREA 1100 SQ FT.permit issued from this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48811	16041-30000-33622	9200 N OAKDALE AVE #500	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 in existing building office space T.I. Suite 500 Total area: 15,810 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48812	15041-10000-23211	20909 S LA SALLE AVE	90501	15	051B193    13	7349003010	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	33.83946	-118.30536	PV1, INSTALL 5.83 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY. (22) MODULES: KYOCERA KU2656ZPA(1) ABB PVI-5000-OUTD-US-Z-D	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48813	17041-10000-33535	747 N LILLIAN WAY	90038	13	141B185   328	5533032022	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.08482	-118.32797	PC FOR FA SYSTEM FOR APARTMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48814	11041-20000-16964	12020 W CHANDLER BLVD 3rd floor	91607	2	171B165   117	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.16825	-118.39512	Ti in an existing office. EPC is for T24& Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48815	19041-20000-49683	132 N ROSEMONT AVE	90026	13	136-5A205 182	5157018024	R3-1	Central	Westlake	Echo Park		2085.01	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM	04/27/2021 12:00:00 AM		Issued	04/27/2021 12:00:00 AM	ADDRESS	34.06864	-118.27209	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK CONSISTS OF NEW 800A SERVICE, 30 HP MOTOR, (4) EQUIPMENTS, (241) BRANCH CIRCUITS, (19) PANELS, AND T24 TOTAL SQUARE FOOTAGE = 12990 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48816	17041-30000-33521	2049 S CENTURY PARK EAST 8th Floor-Lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 onl. in existing highrise elevator lobby 8th Floor. Total area: 295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48817	19041-10000-00292	4314 W ADAMS BLVD	90018	10	123B185   717	5051005901	C2-1-O-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.02	Electrical	Electrical	Apartment			01/03/2019 12:00:00 AM	02/26/2021 12:00:00 AM		Permit Finaled	09/08/2022 12:00:00 AM	ADDRESS	34.03238	-118.33225	NEW 4 STORY, 38 UNITS OF AFFORDABLE  HOUSING OVER GRADE PARKING AND COMMON AREAS. FULL PLAN CHECK FOR POWER & ENERGY. (FEE ESTIMATE. VERIFY FEES DURING PLAN CHECK)BUILDING PERMIT: 19041-10000-00030	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48818	11041-20000-02551	22827 W VENTURA BLVD	91367	3	171B097   416	2042017018	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	07/18/2012 12:00:00 AM	PIN	34.16604326	-118.62429765	energy plan check foot massage	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48819	14041-10000-34502	1605 W LOCKNESS PL	90501	15	045B193   409	7347017042	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.81824	-118.3057	T24, REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 6908 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48820	16041-10000-43356	16244 W NORDHOFF ST	91343	12	195B137    14	2688003***	PF-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.23547	-118.48623	FA PANEL UPGRADE. INSTALLING NEW PANEL AND MODULES TO MAKE EXISTING LINES ADDRESSABLE. PC FOR UPDATED BATTERY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48821	19041-30000-39678	700 S FLOWER ST 14TH FL	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Issued	10/01/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR T-24 ONLY, NON-STRUCTURAL TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN LOBBY AND RESTROOMS AREAS. TOTAL SQ. FT. 1158.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48822	14041-20000-00283	833 1/2 W 40TH PL	90037	9	114B197   280	5019001010	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Expired	03/10/2016 12:00:00 AM	ADDRESS	34.01017	-118.28839	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 2.5KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48823	16041-20001-22352	19202 W SANTA RITA ST	91356	3	171B121   218	2163010006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	34.16697	-118.55148	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 18.20 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48824	18041-10000-30746	1055 S LA CIENEGA BLVD	90035	5	132B173   572	4332030021	C2-1-O, [Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.05785	-118.37637	NEW GYMNASIUM ACCESSORY TO AN EXISTING SCHOOLPLAN CHECK FOR POWER AND ENERGY.BLDG PERMIT: 17010-10000-04882	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48825	19041-10001-13366	7115 S HAAS AVE	90047	8	102B189  1212	6016032023	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	ADDRESS	33.97516	-118.31697	VOID (Master permit was updated to single family dwelling) .. Fee is $0 per AB1414. PC only. Change the project type to Single Family Dwelling. The project was previously issued as commercial under master permit. Original Scope: pc for pv . system includes (19)Hanwha Q-cell W/P320 optimizers. (1) central inverter (solar edge SE5000H). (1) 30A disconnect switch.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48826	15041-20000-23652	1380 E PRESTON WAY	90291	11	111B149   107	4244028021	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.00399	-118.45222	PV1. Install roof mounted PV system sized 7.5 kW. Interconnected with main service panel. (25) Sunpower X21-333 Modules(1) Fronius IG plus 7.5 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48827	18041-10000-32050	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	PLAN CHECK FOR FIRE ALARM SYSTEM CONNECTING TO EXISTING SYSTEM - TOTAL OF 157 DEVICES AND FIRE ALARM PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48828	19041-20000-12478	12147 W VENTURA BLVD	91604	2	162B165    22	2367016008	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.14356	-118.39685	Plan check for Title 24 only Tenant Improvemet in existing space. Total area: 1783 sq ft. B#19016-20000-08144	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48829	09041-20001-19616	4700 N LOUISE AVE	91316	5	168B133   426	2289009015	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2010 12:00:00 AM			PC Approved	10/13/2010 12:00:00 AM	ADDRESS	34.15474	-118.50947	Revision to approved plans. Delta 2 Plan check, changing Cu feeders to Al feeders.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48830	18041-10000-39962	13490 W FOOTHILL BLVD	91342	7	222B157   290	2513007041	RD1.5-1XL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Issued	10/19/2018 12:00:00 AM	ADDRESS	34.30485	-118.42772	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY, Total sq. ft. 3600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48831	14041-10000-17228	3655 S GRAND AVE	90007	9	118-5A203 278	5122023028	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			Corrections Issued	07/29/2014 12:00:00 AM	ADDRESS	34.01726	-118.27819	PC FOR T24 ONLY. TOTAL AREA 13670 SQ FT. FOOD COURT LIGHTING. SUBMITTAL PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48832	16041-20000-45669	9450 N FARRALONE AVE	91311	12	198B101    81	2727019015	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Issued	12/29/2016 12:00:00 AM	ADDRESS	34.24219	-118.61024	pv1install roof mounted pv system sized 3.4kw interconnected with msp. Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48833	11041-20001-05100	14149 W BESSEMER ST	91401	6	177B153   709	2240023007	M2-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM			PC Info Complete	08/15/2012 12:00:00 AM	ADDRESS	34.18092	-118.44162	Add three subpanels (HPA1, HPA2, and HPA3) that were originally allocated as future panel loads.  All changes on the plans are indicated by REVISION 2.  Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48834	18041-10002-00850	1030 N SWARTHMORE AVE SP2-108	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM			PC Approved	06/04/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR CHANGES TO APPROVED SET UNDER DELTA  5. Changes include removing receptacles in kitchen, relocating AHU units on the floor plans with circuit designation, revising lighting floor plans, revising panel schedules, and title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48835	19041-10000-35083	12105 W WATERFRONT DR 4TH FL	90094	11	105B161  1195	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	04/17/2020 12:00:00 AM	ADDRESS	33.98095	-118.40764	Full plan check for an office T.I located on the 4th floor of a commercial building. Scope includes new lighting and equipment with a total lighting area of 11,721-SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48836	19041-10000-35428	3324 S LA CIENEGA BLVD	90016	10	120B173   227	5048016028	C2-1-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			PC Info Complete	09/06/2019 12:00:00 AM	ADDRESS	34.02748	-118.37183	T-24 PLAN CHECK FOR A TI TO RETAIL STORE. SCOPE INCLUDES NEW RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1955 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48837	11041-10000-20813	4157 N EAGLE ROCK BLVD 1-9	90065	14	156A219   132	5473006017	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	34.12193	-118.22559	T.I. for a massage parlor to change light in restroom.  PLAN CHECK ONLY for Energy.  All emergency lighting is existing, not to be modified per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48838	10041-10000-19732	520 S VIRGIL AVE # 306	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM			Corrections Issued	10/19/2010 12:00:00 AM	ADDRESS	34.06457	-118.28687	CHANGE OF USE  CONVERTING AN OFFICE SPACE TO ORTHODONTIST'S OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48839	18041-20002-30350	1249 N SHADYBROOK DR	90210	5	144B157   140	4357017013	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.09363	-118.42976	12/13/2018changes to an approved set of plans.  changes to solarworld 295W modules, 64 total.this is plan check only.  ((((Plan check for a PV1 roof-mounted PV system. System size is 17.98 kWdc/15.86 kWac-CEC and consists of (64) micro-inverters, (64) modules, and (1) load center.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48840	19041-10000-05677	5128 N FIGUEROA ST	90042	1	150A227   154	5468005032	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	ADDRESS	34.1059	-118.19991	Energy plan check for a carwash T.I; Scope include new lighting and equipment with a total area of 11,872-SQ FT.Note ( Portion of permit fee is paid under 18041-10000-17113 NEW 400 AMP SERVICE/ELECTRICAL WORK)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48841	13041-20001-17467	8223 S FIGUEROA ST	90003	8	099B201  1336	6032021012	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Apartment			07/02/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	33.96368	-118.28297	((CHANGED VOLTAGE CLASS FROM 120/208 TO 120/240 DURING VERIFICATION. PLAN CHECK HOURS HAVE BEEN CHARGED))New 37 unit apartment building.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48842	15041-20000-42770	1515 W 190TH ST Ste 460	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	33.85852	-118.30531	Existing 2327 sq ft commercial office remodel.  New lights, existing circuits.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48843	15041-10000-22357	100 WORLD WAY TER1-SPT154FB	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR POWER AND ENERGY. NEW RESTURANT IN LAX TERMINAL 1, TOTAL AREA 4000 SQ FT.PER APPLICANT FEE.-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48844	18041-20000-21445	12000 N BRADFORD PL	91344	12	216B133   253	2606003037	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.28934	-118.50368	Plan check for PV  roof mounted sysem 7.0kW with 29 modules and 2 inverters(3.0kW and 4.0kW) connected to MSP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48845	11041-20000-14315	17383 W SUNSET BLVD B 140	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.03917	-118.55529	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR CHANGE OF USE FROM OFFICE TO BANK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48846	14041-10000-05440	800 S LA BREA AVE	90036	4	132B181   271	5084003001	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.06027	-118.34454	Remove HID light fixtures in existing commercial auto repair space and replace with fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48847	16041-20001-40262	1635 N FORMOSA AVE	90046	4	147B181   282	5548009021	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	06/16/2017 12:00:00 AM	ADDRESS	34.1008	-118.34688	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 30.4kW (5kW*3+7.7kW*2) ungrounded system. (118) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48848	17041-20000-34519	3333 N ALANA DR	91403	5	159B141   364	2280025024	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.13165	-118.47767	Plan check for solar pv system (roof-mounted array) for SFD.11.4kW ungrounded pv system. (47) 325W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48849	16041-20001-20339	410 W 7TH ST	90014	14	129A209   222	5144013021	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	01/22/2020 12:00:00 AM	ADDRESS	34.04606	-118.25495	Revisions to approved plans.  Series ratings applied to system design, elevator motor HP rating revisions, replacement of integral battery backup to EM lighting inverter.  Miscellaneous load changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48850	15041-10000-27625	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	33.74512	-118.26099	ADDING TWO MCC'S TO AN EXISTING 6 MCCs. NEW MOTOR LOADS ADDED TO EXISTING 6 MCC'S WITH ADDED LOAD.  PC FOR POWER ONLY. AUTHORIZED BY JOHN IBRAHIMI, LA PORT DEPT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48851	16041-10000-34288	725 S FIGUEROA ST 10th RR	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	T-24, PC FOR ENERGY ONLY. T.I TO AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS IN WOMEN AND MEN'S RESTROOMS. TOTAL AFFECTED AREA IS 499 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48852	10041-10000-10137	1600 N VINE ST #186	90028	13	148-5A189 346	4307013027	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM	06/28/2010 12:00:00 AM		Permit Finaled	10/27/2010 12:00:00 AM	ADDRESS	34.1	-118.32647	First time tenant in space 186, full plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48853	17041-10000-40578	7357 N JORDAN AVE	91303	3	186B105   622	2111012023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.20438	-118.603	PC for T24 ony for outdoor lighting for replacement of existing fixtureswith LED fixture. Total of 23400sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48854	19041-10000-20063	7431 N FALLBROOK AVE	91307	12	186B097   629	2021016019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.20521	-118.62363	PC FOR PV SYSTEM. SYSTEM SIZE IS 7.125KW. SYSTEM CONSISTS OF (25) HANWHA Q-CELL MODULES W/(25) P320 OPTIMIZERS, (1) SE6000 SOLAREDGE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48855	18041-20000-23645	3420 E ALTA PL	90031	1	141A225   131	5208017039	[Q]RE20-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	10/07/2020 12:00:00 AM	ADDRESS	34.08132	-118.20468	Plan check for a PV1 ground-mounted PV system. System size is 14.04 kWdc/12.48 kWac-CEC and consists of (39) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48856	14041-20000-01376	1404 N HOOVER ST	90027	4	147A201   153	5430032010	R2-1XL	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.09698	-118.28392	New PV rooftop system for an existing single family dwelling.  System uses Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48857	16041-20000-45306	12641 W BEATRICE ST	90066	11	105B161  1007	4211006011	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	09/07/2017 12:00:00 AM		Issued	09/07/2017 12:00:00 AM	PIN	33.98050018	-118.41745021	service upgrade to new 2000A main service panel. Subfeed old 1000A main panel from new main with additional new loads.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48858	14041-20000-20432	13791 N GAVINA AVE	91342	7	228B161   278	2582029041	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Expired	08/31/2016 12:00:00 AM	ADDRESS	34.32268	-118.40825	Standard plan for 7.65KW PV1 roof-mounted system including: (1) Solaredge SE6000A , (30) Trina Solar TSM-255 modules  and  Power-One P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48859	19041-10000-47909	11136 W OPHIR DR	90024	5	135B149    98	4366027016	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/28/2019 12:00:00 AM	ADDRESS	34.06927	-118.45629	Plan Check for PV-1 system, system size 5.28KW, 16 Solar modules with microinverters and Enphase combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48860	19041-20000-04017	12114 N DARBY AVE	91326	12	219B121   405	2870003003	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Issued	02/01/2019 12:00:00 AM	ADDRESS	34.29297	-118.54163	Plan check for PV roof mounted system, system size: 11.8KW DC with 36 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48861	15041-20000-43429	9660 N ANTELOPE ROAD	90210	5	153B157   412	4384006028	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.11672	-118.42408	New 2-story SFD with attached 9-car garage.  New 1200 A 120V/208Y service with optional backup generator.  Electrical wiring permit fees paid under residential combination permit issued under 15010-10000-03500.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48862	12041-20000-13844	20730 W PRAIRIE ST	91311	12	198B109    81	2748002048	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.24073	-118.58534	Replace two 5000A switchboard panels.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48863	14041-10002-13184	7448 N MILWOOD AVE	91303	3	186B105   426	2112010006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.206	-118.59415	CHANGES TO APPROVED SET OF PLANS. PLAN CHJECK ONLY.  LOAD CALCS PROVIDED TO PROVIDE 175A MAIN DISCONNECT WITH 60A SOLAR DISCONNECT.PV1, INSTALL A 11.55 KW DC ROOF-MOUNTED SOLAR ARRAY. INTERCONNECT WITH SERVICE PANEL. TRANSFORMERED. LOW PERMIT FEES DUE TO 2012 SENATE BILL NO. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48864	13041-10000-19154	333 S GRAND AVE	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	NEW FIREALARM FOR TENANT SPACE. HIGH RISE: WORK IS ON 46 STORY. 20 DEVICES AND 1 PANEL. 1 BRANCH CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48865	17041-10000-18404	19862 W VINTAGE ST	91311	12	204B113   725	2726005001	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.25166	-118.56633	Installation of new roof mounted solar PV system on existing single family dwelling.  AC module system.  Total system size = 10.8 kWac(30)AC Modules-SPR-X22-360-C-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48866	13041-10000-05440	2049 S CENTURY PARK EAST FLOOR 36	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	03/01/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	RENOVATION OF OFFICE SPACE. NO CHANGE OF USE. TOTAL AREA 19060 SQ FT. PC FOR T24 ONLY. PC ONLY, PERMIT TO BE ISSUED FROM PC STAFF ONLY. WORK DONE ON 36 FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48867	18041-10000-13264	10635 W WILSHIRE BLVD 1-46	90024	5	132B153    69	4360011003	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	03/15/2021 12:00:00 AM	ADDRESS	34.06138	-118.43484	PLAN CHECK FOR TITLE 24 ONLY FOR TI WITHIN COMMON AREAS OF AN APPARTMENT COMPLEX(LOW RISE BUILDING). EMERGENCY LIGHTING SHALL BE PROVIDED BY INVERTER(90 MIN. MINIMUM)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48868	19041-20000-12698	17966 W LAKE VISTA DR	91316	5	162B125   185	2184048003	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.1415	-118.52572	PV1.  Install 11.88 kW DC / 10.09 kW AC roof mounted grid tied PV system.  (36) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48869	18041-10000-15486	124 E I ST	90744	15	030B205   159	7423003901	PF-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	33.7811	-118.26157	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48870	16041-20000-18381	5500 N LANKERSHIM BLVD	91601	2	174B173  1383	2348003041	C2-2D, R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.17013	-118.37756	PLANCHECK FOR POWER AND ENERGY.  NEW 2-STORY  AUTO SALES SHOWROOM FOR NEW CARS DEALER ,  AND PART SALES.  NEW SERVICE CANOPIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48871	19041-20000-45899	11600 W DONA ALICIA PL	91604	2	159B169   561	2381014007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.13056	-118.38686	Plan check for PV roof mounted system, PV system size: 7.59KW with 23 PV Modules and 23 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48872	16041-10000-28873	811 S COLUMBIA AVE	90017	1	130-5A205 313	5142020004	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.05013	-118.27038	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES TI-24 ONLY. tOTAL AREA: 67,480 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48873	18041-10000-24183	10801 W CHANDLER BLVD	91601	2	174B173  1312	2416015900	PF-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/29/2020 12:00:00 AM		Permit Finaled	10/21/2022 12:00:00 AM	ADDRESS	34.16881	-118.36593	PC FOR POWER AND ENERGY FOR A NEW 2 STORY OFFICE BUILDING AND STORAGE ON 1ST FLOOR. SCOPE INCLUDES ADDING A NEW 1000A 120/208 3PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 54,844 SQ. FT.  B#18010-10000-01190	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48874	17041-20000-05690	21911 W VENTURA BLVD	91364	3	174B105    56	2168027037	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.16867	-118.60457	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO (E) RESTAURANT.  618 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48875	14041-10000-15013	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.01118	-118.33649	TITLE 24 PLAN CHECK ONLY TOTAL AREA = 5079 SQ FT.REMODELING A RETAIL TO NEW RETAIL IN MALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48876	10041-10000-22261	249 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.0498	-118.22618	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48877	18041-20000-04788	13155 W HARTSOOK ST	91423	4	171B157   686	2358001002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.16408	-118.41994	install (1) tesla powerwall to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48878	14041-20000-13617	127 S SAN VICENTE BLVD ROOF	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.07457	-118.37864	INSTALLING TWO 15 HP AND TWO 50HP  AIR HANDLING UNITS.  PERMIT PREVIOUSLY PULLED UNDER 14041-20000-12723.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48879	13041-20000-32441	22635 W VENTURA BLVD A	91367	3	171B097   166	2040028010	C1.5-1VLD, C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/20/2013 12:00:00 AM	PIN	34.16770476	-118.62042219	PC FOR T24 ENERGY ONLY. NEW YOUGURT. TOTAL AREA 1110 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48880	15041-10000-00038	4370 E WORTH ST	90063	14	135A229   163	5224005013	M3-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.06263	-118.19051	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 40120 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48881	17041-20000-20728	8405 N GLENOAKS BLVD	91352	6	192B177   484	2404019047	(Q)R3-1-CUGU, R3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Apartment			06/20/2017 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	09/19/2023 12:00:00 AM	ADDRESS	34.22264	-118.35972	Plan check for power and energy. New 19-unit, 4-story apartment building. 1000A 120/208V 3ph 4w service.T24 area - 18,534sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48882	18041-10001-18835	1232 W 61ST ST	90044	9	105B197   778	6003025007	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM			PC Approved	08/10/2018 12:00:00 AM	ADDRESS	33.98404	-118.29697	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOAL SYSTEM SIZE IS 5.60KWdc / 6.00KWac  (16)MODULES-HYUNDAI HiS-S350TI(16)OPTIMIZERS-SOLAREDGE P370(1)INVERTER-SOLAREDGE SE6000A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48883	15041-20000-05963	348 W 70TH ST	90003	9	102B201   553	6012011058	R2-1	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	33.97628	-118.28004	Installation of new roof mounted solar PV microinverter array.  Total system size = 5.59 kWacNote: PV plan check over the counter because B contractor can not pull permit online.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48884	12041-10000-26233	854 W DOWNEY WAY	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.02013	-118.28757	Two Story engineering building in USC (Robert Glenn Rapp building). New fire alarm panel and 157 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48885	17041-20000-22494	941 S FEDORA ST	90006	10	132B197  1034	5094022036	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			07/05/2017 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.05469	-118.29779	PLANCHECK FOR POWER AND ENERGY. 15 UNIT APARTMENT BUILDING. FOUR STORY  WITH BASEMENT. FIRE ALARM VARIANCE HAS BEEN SUBMITTEDBUILDING PERMIT # 17010-20000-00090	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48886	17041-20000-30881	12316 W LULL ST	91605	2	186B165   178	2307016014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.20927	-118.40147	PV1.  Install 11.04 kW DC (10.24 kW AC) roof mounted grid tied PV system.  AC modules.  Derating main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48887	17041-20000-10065	12035 W WILSHIRE BLVD	90025	11	126B145    25	4265016043	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.04541	-118.46622	New 3000 amp service for 5 story mix use apartment building.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48888	18041-20000-45700	16303 W BIRCHER ST pv1	91344	12	213B137   353	2605018016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.28135	-118.48682	pv1install roof mounted pv system sized 4.1KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48889	12041-10003-07640	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM			PC Approved	04/24/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	((((4/24/2015))))  CHANGES TO AN APPROVE SET OF PLANS.  RELOCATING EXISTING PANELS NOTED DELTA 21.  PANELS TO BE EMPTY WITH NO CONNECTED LOADS.  BRANCH CIRCUITS TO BE PULLED UNDER SEPARATE PERMIT.  Plan check power for LAX Terminal 5 Primary switchgear and distribution (infracture upgrade). New equipment, switchboards, and panels. Existing service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48890	17041-10000-02465	270 S WESTGATE AVE	90049	11	132B145   188	4401004006	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.05824	-118.47125	Plan check for PV roof monted system PV battery back up system. System size: 6kW  and 18 modules, 1 inverter(6.0kW) and Tesla battery (5kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48891	18041-20000-31032												Electrical	Electrical	1 or 2 Family Dwelling			08/15/2018 12:00:00 AM			PC Approved	08/15/2018 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48892	10041-20000-10178	19703 W NORDHOFF ST #19711-19713	91324	12	195B117    46	2782038004	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	06/10/2010 12:00:00 AM		Permit Finaled	10/08/2010 12:00:00 AM	ADDRESS	34.23216	-118.56258	Plan check T-24 Energy for office TI suite #19713 & #19711.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48893	14041-10000-19401	5856 1/2 S FIGUEROA ST	90003	9	108B201  1521	6004036011	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	33.98811	-118.28246	PV2 16.56KWdc. 240V. negative GND. NONstd. ?story. Roofmount. [(2) inverters: {Fronius IG PLUS V 7.5-1UNI, Fronius IG PLUS V 7.5-1UNI}]. [(48)modules: {SUNPOWER {spr-x21-345-com}}]. CHANGES     ON PLAN INCLUDE: NO MAIN ON SOLAR LOAD CENTER.COMMERCIAL PV SYSTEM.  ON FLAT ROOF TOP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48894	19041-20000-50118	17540 W MARGATE ST	91316	5	171B129    79	2257003025	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.16755	-118.51593	PV1.  Install 11.34 kW DC roof mounted PV system.  (36) modules with 10 kW rated inverter.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48895	18041-20000-12682	17701 W REVELLO DR	90272	11	126B117   401	4416020018	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.04145	-118.56116	Plan check for battery back up system Tesla PowerWall 2.0 connected to existing PV System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48896	18041-10000-27438	12308 W COVELLO ST	91605	2	186B165   306	2307023***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.20794	-118.40124	install new PV-1 ROOF TOP ON AN EXISTING SINGLE FAMILY DEWILLING. SYSTEM SIZE 2.475 KW DC/3KW AC. 9 MODULES ONE CENTRAL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48897	15041-10000-20264	12905 W LANDALE ST	91604	2	165B161    71	2362006013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			06/26/2015 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/06/2021 12:00:00 AM	ADDRESS	34.15231	-118.414	**[PLAN CHECK ONLY approved on 2/3/17] Changes from 9 unit to 10 units under 15041-10001-20264. PC for power and energy.  New 9 unit condominium. TOTAL CONDITIONED AREA IS 1427 AND UNCONDITIONED IS 7578 SQUARE FEET.PER APPLICANT FEE CALCULATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48898	11041-10000-00714	5344 N VAN NUYS BLVD	91401	2	172-5A151  27	2248014036	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.1678	-118.4485	New 415 Kw PV system. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48899	14041-10000-34506	1015 S CROCKER ST # Q28	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.0345	-118.2508	T24, REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 1680 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48900	14041-20001-05189	12695 W SANDHILL LANE UNIT 2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	33.97727	-118.41529	((EXPEDITE FEES)))Roof mounted PV system with 3KW AC USING TRANFORMERLESS INVERTER. THIS IS PART OF A SERIES SET OF SUBMITTALS. THIS PV SYSTEM TO INTERCONNECT TO COMMON SERVICE. THIS IS PROJECT 2 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48901	11041-10001-19293	380 W WORLD WAY FAN ROOM-NO.8	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	addition of two new circuits for card reade and upsize the motor-blowers for the SF fans.Renovation and addition to existing Tom Bradley International Terminal building-BRADLEY WEST RENOVATIONS: TO EXISTING MCC-5EZX,ADDING 2 EA 10 HP SF UNITS AS PART OF EDN-027AND CHANGES TO LIGHTING TO CORRIDOR AND CS16-56.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48902	17041-10003-28776	976 E 55TH ST	90011	9	108B209   893	5103019001	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	33.99242	-118.25841	PC FOR REVISION TO APPROVED SET. SCOPE INCLUDES RELOCATING ESS TO WEST WALL. ADDITION OF AC DISCONNECT TO COMPLY WITH CODE. ADDRESSING INSPECTION NOTES. THIS IS PLAN CHECK ONLY! PERMIT FEE UNDER MASTER PERMIT. PC FOR PV SYSTEM WITH BATTERY STORAGE. PV SYSTEM RATED 3KW AC AND BATTERY UNIT RATED 5.8KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48903	16041-10001-06703	600 W WILSHIRE BLVD STE 100	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Issued	11/14/2016 12:00:00 AM	ADDRESS	34.04796	-118.25622	11/14/2016 Changes to an approved set of plans. Changes include removed unit equipment, modify emergency lighing circuit for egress lighting. Changes apply to delta 7 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48904	10041-20000-12919	8379 W 3RD ST	90048	5	138B173   748	5511015015	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM	07/07/2010 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.0731	-118.37273	Upgrading existing 400amp service to 800 amp switch board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48905	15041-20001-35937	10101 W WILSHIRE BLVD South-Course	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.06725	-118.41704	10/24/2017changes to an approved set of plans.  changes noted delta 6.  changes reflect field conditions only, removal of existing equipment.  this is plan check only.(((((Plan check for a medium  voltage project, 4.16KV. Scope includes new substation distribution, and equipment for existing country club. Existing DWPservice located in methane zone.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48906	15041-20000-03256	925 W WEST 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM			PC Approved	02/03/2015 12:00:00 AM	ADDRESS	34.0239	-118.28647	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOMS ONLY. 803 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48907	15041-10000-17997	9000 S BELLANCA AVE	90045	11	096B169  1077	4125010011	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.95506	-118.38038	TI TO AN EXISTING WAREHOUSE.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 74312 INDOOR/OUTDOOR.(((permit pulled with notorized authorization letter)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48908	16041-20000-19928	6584 N FRANRIVERS AVE	91307	12	180B089   403	2034017034	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.19055	-118.65485	PV1.  Install 12.32 kW roof mounted PV system.  (44) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48909	16041-30000-41864	15230 W VANOWEN ST	91405	6	180B145    39	2235004009	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM			PC Info Complete	02/01/2017 12:00:00 AM	ADDRESS	34.19371	-118.46506	Plan check for Title 24 only in existing space T.I. retail O'reilly Auto Store. Total area: 14,933 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48910	14041-10000-17474	910 S FAIRFAX AVE	90036	4	132B177   328	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Public Safety Only			06/27/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.05978	-118.36284	NEW FIRE WARNING SYSTEM AT THE SHALHEVET HIGH SCHOOL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48911	16041-20000-43544	11820 W BLYTHE ST	91605	6	189B169   362	2310022009	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.2147	-118.39068	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (14) modules, and (14) power optimizers. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48912	16041-20000-08859	430 S HOBART BLVD 1-68	90020	10	135B193   543	5503011021	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.06624	-118.30518	PV2.  Install 44.6 kW DC roof-mounted PV system on (E) apartment building.  (4) 9000W inverters with (144) modules.$0 permit fee due to Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48913	19041-10000-23317	1492 W SUNSET BLVD 1-5	90026	1	139-5A209 292	5405001026	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1975.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM			PC Info Complete	10/01/2019 12:00:00 AM	ADDRESS	34.07547	-118.255	pc for new apartment building, 6 units. service size 600A, 1ph, 3wire. area of scope 13,442sf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48914	17041-10000-00759	450 S WESTERN AVE #222	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.06562	-118.30887	Plan check for power and energy 1st time tenant retail/coffee shop  connect to 277/480V 200A  tenant service. Total area: 4000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48915	15041-20000-12394	842 S MANNING AVE	90024	5	135B153   344	4360013011	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM			Reviewed by Supervisor	05/21/2015 12:00:00 AM	ADDRESS	34.06514	-118.43768	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Microinverter system with three branch circuits.  Two branch circuits connect to solar only subpanel which connects to main service panel.  The third branch circuit connects directly to main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48916	15041-20000-04237	21700 W OXNARD ST SUITE 1820	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Issued	02/12/2015 12:00:00 AM	ADDRESS	34.17901	-118.60179	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW CIRCUITS TO EXISTING PANELS.  PLAN CHECK FOE ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1469. SCOPE OF WORK IN SUITE 1820	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48917	14041-20000-31223	11640 W SAN VICENTE BLVD	90049	11	129B145    21	4265005022	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.05369	-118.46307	TI. JUICE BAR. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48918	18041-20000-37506	20714 W BEECH CIR #296	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.2927	-118.5848	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48919	16041-20000-27942	726 S MATEO ST	90021	14	124-5A217 319	5166015007	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.03377	-118.23211	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total outdoor lighting area = 8,817 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48920	18041-20000-43162	6647 N HAYVENHURST AVE	91406	6	180B137   165	2231008009	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.19165	-118.49259	Plan check for a PV1 roof-mounted PV system. System size is 7.8 kWdc/7.02 kWac-CEC and consists of (1) inverter, (26) modules, (1) back-up battery, (1) transformer, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48921	18041-20000-14841	20638 W WALNUT CIR	91326	12	219B109   358	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.29395	-118.58371	PC for rooftop solar for 3.84kW(ac)/4.02kW(dc) for SFD tract home. Installing 12 AC modules with AC disconnect.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48922	16041-10000-32123	17301 W VENTURA BLVD	91316	5	171B133   691	2257016001	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.16106	-118.51005	Energy plan check for a retail (T-mobile)  T.I.  Scope of work is for new lighting only; Total area is 1898 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48923	18041-10000-17063	2941 W 70TH ST	90043	8	102B189   584	4008011058	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	33.97648	-118.3254	25.06 kW AC CEC/ 33.3 kW AC SOLAR PHOTOVALTAIC ROOFTOP SYSTEM.82 PV Modules with Central Inverter. Building Permit: 18016-10000-14625	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48924	18041-20000-44661	11671-11677 W NATIONAL BLVD	90064	11	120B153   907	4258009031	C2-1VL, R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Apartment			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	34.02326	-118.43794	New fire alarm system for 4-story mixed use building.  FACP with 149 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48925	17041-20000-08119	3872 N REKLAW DR	91604	2	162B169   537	2369024007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.14018	-118.38985	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48926	17041-10000-00489	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.20103	-118.38536	PC for power for new 300 kW fuel cell for kaiser building. This application is for building located in 11668 sherman way and is circled on site plan of these plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48927	11041-10000-13658	4950 W SUNSET BLVD Floor 3, 5-, 6	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM			PC Approved	06/30/2011 12:00:00 AM	ADDRESS	34.09786	-118.29745	T24 plan check for alterations to various small work areas on floors 3, 5, and 6 of the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48928	14041-20000-22315	20040 W MAYALL ST	91311	12	204B113   496	2726022003	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Expired	09/15/2016 12:00:00 AM	ADDRESS	34.25351	-118.57032	Standard plan, 5.1 KW PV1 roof-mounted system including: (1)Power One PVI-4.2-OUTD inverter and (20) Trina Solar TSM-255 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48929	15041-20000-09752	10637 W CROCKETT ST	91352	2	192B177   722	2407001043	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.22035	-118.36307	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system with 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48930	19041-10000-20976	767 S ALAMEDA ST suite200	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	PC FOR T-24 ONLY CHANGE OF AN APPROVED SET. AREA 8,110SQFT.inspection fee under original application: 19041-10000-02245BULDING PERMIT: 18016-10000-39891	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48931	11041-10000-08606	1925 S CENTURY PARK EAST	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			Corrections Issued	08/31/2011 12:00:00 AM	ADDRESS	34.06066	-118.41426	T.I. TO AN EXISTING OFFICE BUILDING.  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48932	17041-10000-12692	929 W JEFFERSON BLVD 6D	90007	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	FIRST TI @ SUITES 6D TO CORE-AND-SHELL. JUICE BAR. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48933	12041-10000-11342	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			05/16/2012 12:00:00 AM			PC Approved	05/16/2012 12:00:00 AM	ADDRESS	34.10686	-118.33085	Plan check for T24 Energy/emergeny lighting in corridors of a 5-story residential building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48934	16041-20001-31191	21234 W MULHOLLAND DR	91364	3	162B105    86	2173018006	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.143	-118.59558	EXPEDITE PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48935	18041-10000-00412	550 S HOPE ST SUITE 275	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	CHANGE OF USE FROM OFFICE TO OFFICE FURNITURE SHOW ROOMPLAN CHECK IS FOR TITLE 24 AND ONE EMERGENCY CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48936	17041-20000-17545	4975 W MELROSE AVE	90029	13	141B193   528	5535018033	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.08366	-118.30871	Plan check for energy only. New outdoor site lighting for parking lot and building canopy. 25,648sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48937	10041-10000-03207	1100 N NORTH MAIN ST SUITE B	90012	1	135A217   147	5409010031	[Q]M2-1	Central	Central City North			2060.10	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.06328	-118.23339	PLAN CHECK T-24 ENERGY PLAN CHECK FOR A TI TO A NEW COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48938	11041-10004-26286	901 W OLYMPIC BLVD	90015	14	129A207   293	5138005036	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.04576	-118.26609	Delta 3 changes: revised single line diagram to add rectifiers, 2ea 600A DC panelboards and wiring to supply display signs. building permit required for signs Revised and added schedules for new DC panels.All changes are clouded on the plans Suppl. Application for the changes to the original Plan check for power aNOTE:nd enery for new 23-story Marriot Hotel with 393 rooms.PLAN CHK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48939	19041-10000-08905	12567 W BRANFORD ST	91331	7	201B161   791	2624014089	[Q]M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Info Complete	07/24/2019 12:00:00 AM	ADDRESS	34.2455	-118.40726	Energy plan check for an office/warehouse T.I. Scope includes new lighting and equipment with a total area of 3255-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48940	15041-20001-26452	10250 W CONSTELLATION BLVD 11th&12th-Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Expired	06/20/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 14. CAHNGE INCLUDES LIGHTING FOR TERRACE. NEW CIRCUITS AND T24 PROVIDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48941	14041-20000-33014	11139 N TELFAIR AVE	91331	7	210B153   539	2616022008	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	34.27218	-118.43489	pv1install roof mounted pv system sized 3.8kw interconnected with msp.(18) hyundai heavy his 250w modules(18) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48942	12041-10000-07067	6080 W CENTER DR 11TH Floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	33.97713	-118.39172	INSTALL A NEW 500KW STANDBY GENERATOR AND A 100KVA UPS SYSTEM FOR THE SERVER ROOM ON THE 11TH FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48943	17041-20000-12897	1015 S GAYLEY AVE	90024	5	132B149    55	4363025011	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.06157	-118.44786	Tenant improvement to (E) medical office.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48944	10041-20000-22319	959 E 108TH ST	90002	15	090B209  1489	6051015032	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	PIN	33.9385509	-118.256657	Plan check for roof mounted 94.35KW Photovoltaic System on commercial building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48945	15041-10000-18201	631 W JEFFERSON BLVD	90007	9	120A201    68	5123009010	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.02254	-118.28097	FULL PC FOR A NEW 6 STORY PARKING STRUCTURE WITH LOADING DOCK. PC FOR POWER AND ENERGY TOTAL SQ. FT.  392,669.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48946	11041-20000-12434	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM	06/16/2011 12:00:00 AM		Permit Finaled	06/20/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	Relocate general/emergency lighting in storage room of the mall.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48947	16041-10000-08071	1055 W 55TH ST	90037	9	108B197   752	5002023014	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Expired	04/06/2018 12:00:00 AM	ADDRESS	33.99242	-118.29358	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. STANDARD PLAN IS BEING USED. (28)MODULES-KYOCERA #KD255GX-LFB3(1)INVERTER- ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48948	16041-20000-37727	6734 N VALJEAN AVE	91406	6	180B141    95	2233030031	M1-1-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.19291	-118.48565	remove existing hid fixtures and replace with new led indoor and outdoor.  plan check for energy 28800 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48949	18041-10000-26426	1100 W TEMPLE ST	90012	1	135A211   255	5160025001	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	03/11/2022 12:00:00 AM	ADDRESS	34.06344	-118.2518	NEW 8 STORY, 53  APARTMENT BUILDING . (5 STORIES OF TYPE III-A  APRATMENT OVER 3 STORIES TYPE I-A PARKING GARAGE. SCOPE OF WORK INCLUDES NEW 2000AMP, 120/208V SERVICE.   TOTAL SQ. FT. 91,837. (LOW RISE BUILDING)COMPLY WITH DEPARTMENT ORDER effective date05/29/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48950	13041-20001-29825	5250 N LANKERSHIM BLVD 5TH FLOOR	91601	2	171B173  1421	2350018090		South Valley				1253.20	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Info Complete	12/13/2013 12:00:00 AM	ADDRESS	34.16668	-118.37545	Plan check for Power is requested by applicant.  Energy is on main application #.           <<T24 FOR EXISTING HIGHRISE SCHOOL. SCOPE OF WORK ON THE 5TH FLOOR>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48951	18041-20000-36333	20812 W SPRUCE CIR	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.29505	-118.58766	PV1.  Install 4.06 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48952	15041-20002-17541			4	135B185   445	5507017007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	PIN	34.06415581	-118.33512395	08-13-2015 Change to approved set of plans. Changes include layout of modules. {{{{PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SERVICE 600 AMPS. SYSTEM SIZE: 7KW. (26) LG LG305N MODULES WITH SOLAR EDGE P400 OPTOMIZERS. SOLARD EDGE SE 7600A US INVERTER}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48953	14041-20001-05227	5832 S WEST SEAGLASS CIR	90094	11	102B157   400	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97362	-118.41945	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48954	14041-10002-08145	12665 W VILLAGE LANE block 5	90094	11	102B161  1257	4211034036	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/28/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	33.97786	-118.41484	**Revision to the approve set of plan. Adding 16 devices and changing Horn's model type.(((*Revision to the approve set of plan. Adding less than 10 devices and removing some.<<FA FOR PLAYA VISTA II BLOCK 5. 4 buildings but only 1 FACP. Fee arrangment to be verified by plan checker.>>)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48955	13041-10000-35289	5161 N LANKERSHIM BLVD STE #280	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.16452	-118.37469	"T24 PART 6 ENERGY FOR (E) OFFICE SPACE, LOW-RISE. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING WORK IS APPROX. 1990 SQ FT. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.""COMPLY WITH DEPARTMENT ORDER effective date10/28/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48956	11041-10000-14261	1874 S WESTERN AVE	90006	10	126B193   874	5074015047	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			Corrections Issued	07/08/2011 12:00:00 AM	ADDRESS	34.04037	-118.3088	T.I.  Existing 7-11.  Replacing the existing flourescent light fixtures with LED fixture in the retail area.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48957	19041-10000-16379	5140 S CENTRAL AVE	90011	9	111A209   462	5104001032	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	33.99615	-118.25625	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48958	14041-10000-04384	8540 S SEPULVEDA BLVD STE 103	90045	11	096B165   472	4107035017	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	ADDRESS	33.96016	-118.39599	TI for commercial storage space in a medical office tenant suite.  Title 24 plan check for changes to lighting system per inspector request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48959	11041-20000-20971	7720 N GLORIA AVE	91406	6	189B141   261	2206010045	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/30/2011 12:00:00 AM	09/30/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.211	-118.47917	Plan check T24 energy for animal room. Permit for new lighting on existing fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48960	11041-10000-02066	3701 W SANTA ROSALIA DR	90008	8	114B185   631	5032002042	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/02/2011 12:00:00 AM	05/18/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.00755	-118.33781	NEW STAPLES STORE AT THE BALDWINS HILLS CRENSHAW PLAZA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48961	14041-20001-03565	11166 W LUCERNE AVE	90230	11	111B165   165	4215005005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.00102	-118.40183	PV1 SINGLE FAMILY DWELLING. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS((((EXPEDITE FEES))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48962	16041-20000-21939	7938 N KEER DR	91335	12	189B125  1027	2102015100	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21514	-118.53476	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48963	18041-20000-19670	3710 N WINFORD DR	91356	3	162B121   118	2177043026	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.13618	-118.55116	PV1.  Install 3 kW roof mounted grid tied PV system.  (10) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48964	19041-20000-11122	23150 W AVENUE SAN LUIS pv3	91364	3	171B093   784	2074021035	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.16135	-118.63106	permit fees $0.00 by state senate bill no. 1222Plan check for PV roof mounted system, system size: 73.3kW AC and 83.22KW DC with 228 PV Modules and 2 inverters(20KW) and (1) inverter (33.3KW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48965	14041-20000-19930	11262 N ILEX AVE	91331	7	210B153   208	2616020010	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.27458	-118.43298	new commercial building. 400A service. plan check for T24 energy only. new lighting for indoor and outdoor. Per building submittal, plan check in accordance to 2008 building efficiency standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48966	16041-10000-35657	836 W 30TH ST	90731	15	009B197  1349	7469010009	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Apartment			10/07/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	33.71751	-118.29663	Installation of new roof mounted solar PV array on existing 3 unit apartment building.  Total system size = 3 kWac.  Central inverter with new AC load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48967	19041-10001-08009	1661 W 240TH ST	90710	15	042B193   713	7439007033	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM			PC Approved	02/21/2020 12:00:00 AM	ADDRESS	33.80741	-118.3065	Expediter per applicant request.Plan check for a roofmounted 560KW DC / 662KW AC CEC / 725KW DC PV2 system. Scope includes (1836) modules, (918) optimizers,(51) strings, and (5) inverter interconnecting to the service panel. Note:this project is a second phase for the pv system. All service and switchgear is under 1st phase with the application #: 19041-10000-07987	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48968	15041-10001-25437	2155 N STRADELLA ROAD	90077	5	150B145    31	4377028001	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	34.11089	-118.46248	EXPEDITE PER CUSTOMER REQUEST.(((PV112KW ROOF MOUNTED SYSTEM WTIH (55) kYOCERA KU26556ZPA MODULES AND (2) ABB PVI-6000-OUTD INVERTERS INTERCONNECTED WITH MSP.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48969	11041-10000-17388	752 N LA CIENEGA BLVD	90069	5	141B173   248	5528001061	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.085	-118.37633	TENANT IMPROVEMENT OF THE CURRENT SPACE. COMBINE TWO TENANT SPACES INTO ONE TENANT SPACE.ADD A SALES DESK, ACCESSIBILITY FEATURES, AND AN EMPLOYEE LOUNGE.   CHANGE IN USE.    PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48970	16041-30000-00164	19811 W RINALDI ST	91326	12	213B113   306	2701040048	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	10/05/2016 12:00:00 AM	ADDRESS	34.27712	-118.56526	Title 24 plan check only.  Total area = 8,004 sq. ft.     T.I. to existing retail space.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48971	12041-10000-16639	13324 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	11/08/2012 12:00:00 AM	ADDRESS	34.15935	-118.42332	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48972	16041-30002-44582	1660 W BEVERLY BLVD	90026	13	135A207   240	5153012003	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM			PC Approved	02/15/2018 12:00:00 AM	ADDRESS	34.06404	-118.26497	02-15-2018 Changes to permitted set of plan. Changes include remove inverter circuit from exit sign and put battery back up for exit sign connected to normal circuit. Changes apply to delta 3 only. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48973	17041-20000-37018	1032 W 18TH ST	90015	1	126A203   211	5135026012	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.03916	-118.28001	Interior remodel of (E) sanitarium.  New 400A 120/240V service.  Plan check for power and energy.Note: Building permit filed under 17016-20000-29958. Originally submitted for power due to proposed 600-amp service. Service is now a 400-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48974	19041-10001-00600	10351 W ARNWOOD ROAD	91342	7	210B177    49	2529004008	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.27585	-118.35462	(((Expedite Fees))) NEW ROOF MOUNTED 16.43 KW (DC) PV SYSTEM WITH 53 PV MODULES AND 2 INVERTERS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48975	09041-10006-08059	6250 W HOLLYWOOD BLVD	90028	13	148-5A189 132	5546029917	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/15/2010 12:00:00 AM	01/15/2010 12:00:00 AM		Permit Finaled	02/11/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	Revise the panels schedules and add circits, equipment, and exit signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48976	13041-10002-02351	11725 N HUNNEWELL AVE	91342	7	213B165   172	2531032029	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1042.04	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.28326	-118.4002	(((changes to approved set of plans - rearranged the location of the modules. applicant requested plan check instead of having modified plans. PLAN CHECK ONLY)))--------------1st modificationMODIFICATION TO APPROVED SET OF PLANS. ADDITION OF TWO MODULES AND MAIN PANEL UPGRADE.  SYSTEMS SIZE INCREASED TO 5.184 KW. MODULES CHANGED FROM REC 245 TO REC 230PE-US.  *****************************************************************************originalPHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY TWO STORY DWELLING. TOTAL SYSTEM SIZE OF 4.75KW. USING 22 MODULES. ENPHASE M215-60-2LL-S22 MICROINVERTER. SOLAR PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48977	19041-10000-14842	730 S SERRANO AVE 1-32	90005	10	132B193   438	5093014020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			04/23/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.05884	-118.30642	Power plan check for 30-unit apartment building remodeling.  Scope includes all new ckts and panels for each unit with an existing service and common area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48978	19041-20001-30275	243 E 5TH ST	90013	14	127-5A213  13	5148010006	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM			Verifications in Progress	10/04/2019 12:00:00 AM	ADDRESS	34.04537	-118.24623	Expedited plan check fee.PV2.  Install 46.44 kW DC / 41.74 kW AC roof mounted grid tied PV system. (172) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48979	11041-20000-17519	700 W CHILDS WAY	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	34.01978	-118.28463	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48980	13041-10002-30098	18803 W MAPLEWOOD LANE	91326	12	207B121   786	2728031078	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.26044	-118.54324	Expedited RSES plan check per applicant request.(((PV1, Install 5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 20 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48981	14041-10000-09093	1525 W SUNSET BLVD	90026	13	139-5A209 206	5419027002	[Q]C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Issued	04/07/2014 12:00:00 AM	ADDRESS	34.07631	-118.25581	TENANT IMPROVEMENT ON EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48982	13041-10000-04081	5560 N VINELAND AVE	91601	2	174B173   998	2416001050	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	ADDRESS	34.17168	-118.37009	INSPECTOR TO VERIFY IF HAZARDOUS/CLASSIFIED.PC FOR ENERGY ONLY. CASA DE TORTILLA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48983	13041-10000-30912	1201 N GARBO LN	90038	4	144B185  1348	5532004041	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	PIN	34.09270578	-118.33667375	PV1, Install 1.59 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One  AURORA PV1-3.0-OUTD-S-US. 6 modules: Suniva OPT265-60-4-1B0. 3 story townhouse	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48984	16041-20002-40733	14043 W AUBREY ROAD	90210	4	159B153    17	2272033060	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.13567	-118.44026	[[[10/5/17 CHANGES TO APPROVED PLANS. PLANCHECK ONLY. CHANGING INVERTER TO MATCH THE 120/240V 3 PHASE SERVICE,  (3) SINGLE PHASE INVERTER CONNECTED TO 3 PHASE SERVICE]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48985	17041-10000-35464	3085 N FRANKLIN CANYON DR	90210	4	159B161   380	4386001010	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.12877	-118.40759	NEW 28.8KW PV SYSTEM INSTALLED ON ROOF OF SFD AND CONSISTING OF TWO SOLAR EDGE INVERTERS, 86 MODULES EACH WITH  SOLAREDGE P400 OPTIMIZERS, AND BATTERY BASED STORAGE SYSTEMpermit isnil per senate bill 122	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48986	16041-10002-22231	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			05/22/2017 12:00:00 AM			PC Approved	05/22/2017 12:00:00 AM	ADDRESS	34.03982	-118.24098	Delta 3 Changes : phase converter for the elevator; reduce the size of the inverter; reconfigure wiring to hvac units and replacing their branch circuit breakers with smaller ampere ratings; adding dimming controls for luminaires. CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA 3PLAN CHK ONLY((((((((PC FOR POWER AND ENERGY. INTERIOR/EXTERIOR BUILDING RENOVATION/REPAIRS/ALTERATIONS.UPGRADES AND IMPROVEMENTS TO UNITS. UPGRADING SERVICE FROM 600A TO 800A. ADDING RESTROOMS. TOTAL AREA 9965 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48987	15041-20000-16814	6344 N TOPANGA CANYON BLVD A-1075	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	Plan check for power and energy. Project scope is a first time tenant at The Westfield Village. Work includes the installation of (3) new panels, a 75 kVA transformer, and associated loads. Total lighting area = 1,116 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48988	19041-20000-44209	6770 N CANOGA AVE	91303	3	180B105    19	2148032902	PF-1XL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	10/02/2020 12:00:00 AM	ADDRESS	34.1935	-118.59722	PLAN CHECK FOR INSTALLING A NEW 2500A SERVICE, 2500A SWITCHBOARD, AND (2) 660 KVA EV CHARGERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48989	18041-30000-26159	2029 S CENTURY PARK EAST #1280	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Energy plan check for relocating (7) recessed light fixtures for offices with a total of 335 SQ FT. Permit fee is paid under 18041-90000-24448.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48990	16041-30000-30894	4145 N STANSBURY AVE	91423	4	165B153   914	2266012019	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.1457	-118.44128	Permit fee is $0.00 due to Senate Bill 1222Plan check for PV roof mounted system. System size: 12.2kW with 54 modules and 3 inverters(3.6kW, 3.6kW and 5.0kW) connected to MSB	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
48991	10041-10000-17695	221 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			Corrections Issued	09/18/2010 12:00:00 AM	ADDRESS	34.04947	-118.22718	Solar voltaic system installed on the roof of the building.  Consists of  9 modules,  9 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48992	14041-10000-28263	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.20696	-118.3417	plan check for t24, TI, office no change of use, total area 641 sq ft. with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48993	17041-10000-37873	6117 N SHOUP AVE	91367	3	177B101    98	2039006006	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.18134	-118.61486	TITLE 24 ONLY, RELACE outdoor HID FIXURES WITH NEW LED FIXURES, TOTAL SQUARE FOOTAGE 31925 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48994	19041-10000-15330	321 N BIXEL ST	90026	1	135A209   190	5160020028	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Apartment			04/25/2019 12:00:00 AM	04/13/2020 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.06418	-118.25512	PLAN CHECK FOR TITLE 24 ONLY. INSTALL NEW LIGHTS IN COMMON AND OUTDOOR AREA TOTAL AFFECTED AREA 3,760 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48995	17041-10001-29734	1630 W 186TH ST	90248	15	060B193   248	6108002022	P-1VL, [Q]MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	33.86187	-118.30705	Change to approved set by modifying the single line diagram with fault and voltage drop updated. classified area also being updated, and addional a new load added. All changes under delta-F only.(((PC for power and energy for new outdoor Hydrogen gas dispensing facility for Toyota(No public access). PC includes installation of vehicle fuel dispensing, fuel storage, air compressors and device control panel with control diagram on pg E6.1. Total area of 5723 sqft.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
48996	18041-10000-32263	107 N DELFERN DR	90077	5	141B157   130	4358005006	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.08012	-118.42866	PC FOR ROOF MOUNTED PV ON SFD. CONNECTION TO 1200A SERVICESCOPE INCLUDES 18 MODULES AND SINGLE CENTRAL INVERTER. TOTAL SYSTEM SIZE 5.4 KWDC /5.0 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
48997	17041-10000-21046	14401 W VENTURA BLVD	91423	4	166-5A151 296	2265014017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.15069	-118.44613	PC for title -24  only. Remove HID fixtures and replace with new LED fixtures. total affected area 63250 sq.ft (outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
48998	19041-10000-10069	1411 S WESTERN AVE	90006	10	129B193  1518	5073010018	C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.04585	-118.30924	T.I. FOR EXISTING OFFICE AREA-PLAN CHECK IS FOR TITLE 24 ONLYELECTRICAL PERMIT WAS OBTAINED ON 19041-10000-08383	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
48999	10041-20000-05324	17245 W VENTURA BLVD	91316	5	171B133   679	2258012022	[Q]C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM	04/21/2010 12:00:00 AM		Permit Finaled	06/03/2010 12:00:00 AM	ADDRESS	34.16084	-118.50856	CHANGING THE USE FROM CANDY SHOP ( RETAIL ) TO YOGURT SHOP W/ OUTDOOR DININGnew service upgrade submitted separatly under 10041-20000-04541	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49000	16041-20000-07490	3734 N BEVERLY RIDGE DR	91423	4	162B149   449	2274019001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Expired	04/06/2018 12:00:00 AM	ADDRESS	34.13868	-118.44688	Plan check for a PV1 roof-mounted PV system. System size is 8.4 kWac and consists of (2) inverters, (36) modules, (2) combiner boxes, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49001	14041-10001-15887	8018 W BEVERLY BLVD	90048	5	138B177   470	5511003023	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.07593	-118.3645	CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES ON DELTA 4. (((This is a 3 story with a basement. new fire alarm. 130 devices. and one panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49002	19041-10000-33782	3460 W 7TH ST 1-168	90005	10	132B193   313	5093025028	R4-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/10/2021 12:00:00 AM	ADDRESS	34.05958	-118.3025	TI IN AN EXISTING OFFICE AREA. INSTALLING LIGHTS. T-24 ENERGY ONLY.BULDING PERMIT: 19016-10000-13920	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49003	10041-20000-16644	12304 W SANTA MONICA BLVD	90025	11	126B145   865	4267031001	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	10/28/2010 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	ADDRESS	34.03925	-118.46584	Plan check for installation of 25KW Photovoltaic system and reduce the main breaker to 700A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49004	18041-10000-34114	10250 W SANTA MONICA BLVD 2863	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Issued	10/23/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for a first time retail tenant T.I. Scope includes new lighting and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49005	12041-20000-12034	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	T.I. to existing high rise building on the 5th floor of suite #500.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49006	19041-20000-32148	16830 W VENTURA BLVD Ste 140	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.15886	-118.50032	Power and lighting for commercial tenant space.  Plan check for energy - 1818 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49007	14041-20000-00329	18425 W BURBANK BLVD # 611	91356	3	174B125   635	2160001023	C2-1L, C4-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.17242	-118.53474	TITLE 24 FOR CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE. NO PHYSICAL WORK TO BE DONE. PSYCHIATRY OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49008	19041-10001-47445	1440 E 41ST ST	90011	9	115-5A211 269	5116011027	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	03/11/2020 12:00:00 AM	ADDRESS	34.00855	-118.24796	EXPEDITED FEES PER APPLICANT'S REQUEST.NEW ROOFTOP SOLAR INSTALLATION. SYSTEM SIZE 22.78KWdc (15.2KWac) USING 68 QP335 MODULES, 68 SE P370 OPTIMIZERS & 2 SE7600H-US CENTRALS INVERTERS. CONNECTED TO AN EXISTING 400Amp SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49009	12041-10000-13597	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Expired	07/08/2014 12:00:00 AM	ADDRESS	33.95466	-118.38556	INSTALLATION OF  (3) PARKING SHADE CANOPIES WITH LUMINAIRES INSTALLED UNDER THE CANOPIESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49010	14041-20000-15212	835 N SEWARD ST	90038	4	141B185    96	5533024028	MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.08621	-118.33326	CHANGE OF USE FROM INDUSTRIAL TO CREATIVE OFFICE AND SOUND STAGE.  PLAN CHECK FOR TITLE 24 PART 6 FOR CHANGES TO LIGHTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49011	18041-20000-39756	12611 W OXNARD ST #1-11	91606	2	177B161   875	2332021018	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Apartment			10/17/2018 12:00:00 AM	05/20/2020 12:00:00 AM		Issued	05/20/2020 12:00:00 AM	ADDRESS	34.17954	-118.40794	Plan check for power and energy for 11 units multi-family building 4 story with 800A Service. Total area: 800 sq ft. B#17010-20000-00030	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49012	14041-10000-15381	17288 W SATICOY ST	91406	6	186B133   237	2203017045	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.20827	-118.5096	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR ATT STORE.  2852 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49013	19041-10000-51220	11134 W WICKS ST	91352	7	201B173   249	2538017002	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	09/18/2020 12:00:00 AM	ADDRESS	34.24867	-118.37346	(E-PLAN) EXISTING PV1 SYSTEM WITH A SERVICE OF 200 AMPS (EXISTING). INSTALLATION INCLUDES 1 ENERGY STORAGE SYSTEM, 1 CENTRAL INVERTER (SE7600H-US), AND 1 PANEL OF 200 AMPSSYSTEM SIZE: 9.12 KW DC; 7.6 KW AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49014	18041-20000-27405	23747 W CROSSON DR	91367	3	174B089   207	2045025010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	PIN	34.17465927	-118.64562326	Plan check for a PV1 roof-mounted PV system. System size is 14 kWdc/12.2 kWac-CEC and consists of (40) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49015	15041-20000-20368	2121 S AVENUE OF THE STARS #2010	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check Title 24 only for Fiance department of high rise T.I. in existing office. Total lighting area: 3,413SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49016	17041-10000-28250	2000 E 7TH ST	90021	14	124-5A217 258	5166015005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.03442	-118.2321	PC for T24 for restuarant TI, PC for new lights. Total of 3500 sqft. Building# 17016-10000-22361. Installing new circuits and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49017	10041-10000-23566	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	01/18/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	New work at terminal 5, remodel of the FIS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49018	16041-10000-20439	1334 S CENTRAL AVE	90021	14	121-5A213   5	5130008044	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Issued	06/21/2016 12:00:00 AM	ADDRESS	34.02855	-118.24651	PC FOR SWITCHGEAR REBUILD. CONTRACTOR REBUILDING SWITCHGEAR AND UPGRADING A FEW PANELS AND BREAKERS TO MEET NEW AIC RATING REQUIREMENTS. UL WILL RECERTIFY THE EQUIPMENT. misc permits charged to recheck existing AIC ratings. breakers in MDP 2 and MDP 3 will need to be replaced with eq rating and match AIC as noted on plans.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49019	10041-10000-18534	8011 N WEBB AVE	91605	6	189B169   196	2310008005	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	ADDRESS	34.21614	-118.3884	Photovoltaic system installed on top of a commercial building.  The location of photo voltaic arrays approved by the fire department.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49020	14041-20000-20699	8759 N ZELZAH AVE	91325	12	195B129   334	2768007006	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Expired	09/26/2016 12:00:00 AM	ADDRESS	34.23054	-118.5232	$0 permit fee due to senate bill 1222 from 2012PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.0KW INTERCONNECTED WITH MSP.(47) TRINA SOLAR TSM255 MODULES(1) SOLAR EDGE SE6000 INVERTER(1) SOLAR EDGE SE5000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49021	19041-20001-21615	5005 N EDENHURST AVE	90039	13	162B201    20	5593012032	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.142	-118.2736	EXPEDITED PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON (2) NEW CARPORTS. SYSTEM SIZE IS 199.8KW DC/153.2KW AC.SCOPE OF WORK INCLUDES (540) HYUNDAI SOLAR MODULES WITH (270) P850 OPTIMIZERS, (4) SE33.3K INVERTERS, A SE20K INVERTER, AND A 230A PANELBOARD2 ELECTRICAL PERMITS ON SAME PLAN, SECOND PERMIT IS 19041-20000-21601PROJECT IS A (E) COMMERCIAL BUILDING WITH 2 NEW CARPORTS AND 3 SOLAR ARRAYS WITH 2 POINTS OF INTERCONNECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49022	11041-20001-00974	8530 N TOBIAS AVE	91402	6	192B149   115	2638039021	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			Corrections Issued	06/11/2011 12:00:00 AM	ADDRESS	34.22569	-118.45152	Modification to an existing approved set of plans.  Changes to lighting, addition of new receptacles, and new panels.  Customer has left the original approved set for reference.  Plan check is for Energy and Power.  <<<<<<T.I. to Food-4-Less.  Install panels, general and emergency lightings.  Plan check for energy and power. Subject for Green Building Compliance.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49023	11041-20001-16710	1940 N BEL-AIR ROAD	90077	5	150A151   662	4370013023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2012 12:00:00 AM			PC Approved	09/18/2012 12:00:00 AM	ADDRESS	34.10426	-118.45104	Modifications to approved plans. Addition of pool panel (future load), 9 kW dehumidifier, and revisions to lights in pool area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49024	18041-10000-29076	1411 S LINCOLN BLVD suite #4	90291	11	111B145  1243	4241008033	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	33.99757	-118.46044	PLAN CHECK FOR TITLE 24 ONLY FOR UPDATE OF EXISTING LIGHT FIXTURES - NO CHANGE OF USE - TOTAL AFFECTED AREA = 800 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49025	15041-10000-43688	234 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM			Reviewed by Supervisor	02/23/2016 12:00:00 AM	ADDRESS	34.05578	-118.25359	ADDITION OF 22,000 SF TO EXISTING HIGH RISE APARTMENT COMMUNITY; FACILITY TO INCLUDE  BASEMENT, LOUNGE, LOBBY, FITNESS CENTER, ROOFTOP DECK AND POOL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49026	18041-30000-08461	1501 N SUMMITRIDGE DR	90210	5	147B157   193	4355005039	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.09868	-118.41997	PV1. Ground-mounted 38.9 kW PV system with (1) 30kWac and 120 pv modules interconnecting to a 800 A 208Y/120V 3ph-4w service.Building application # 17020-10000-02977	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49027	14041-10001-34347	8520 N REMICK AVE	91352	6	192B165   176	2634022013	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.22545	-118.39956	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 4.08 KW DC SOLAR RRAY ON A SINGLE DWELLING HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: REC SOLAR REC256PE BLK (1) INVERTER: POWERONE PVI-3.6-OUTD-S-US-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49028	19041-20000-39302	6330 W SAN VICENTE BLVD Suite 245	90048	5	132B173   186	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.06116	-118.36804	T24 PLAN CHECK FOR TI TO EXISTING COMMERCIAL BUILDING STE 245. LIGHTS AND OUTLETS ONLY TOTAL SQUARE FOOTAGE = 1692 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49029	11041-20000-21645	19851 W NORDHOFF PL # 104	91311	12	198B113   150	2761001081	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	11/02/2011 12:00:00 AM	ADDRESS	34.23624	-118.56649	T24 ENERGY/EMEGENCY LIGHTING FOR T.I. IN EXISTING WAREHOUSE. PERMIT FOR NEW LIGHT FIXTURES ON EXISTING CKTS AND 1 MISC PERMIT FOR LOW VOLTAGE WIRING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49030	15041-20001-35739	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM			PC Approved	09/30/2016 12:00:00 AM	ADDRESS	34.21499	-118.4422	9/30/2016Changes to approved set delta-1 changes only. Changes are clouded. Relocation of panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49031	15041-20002-18343	20508 W BERGAMO WAY	91326	12	210B109   419	2701050042	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.27624	-118.57946	Changes to approved set.  Upgrading main service panel to 200 A MCB with 225 A busbar.Installation of new roof mounted solar PV array.  Total system size = 4.5 kWac.  Microinverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49032	15041-20000-39531	15301 W VENTURA BLVD P36	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.15411	-118.46654	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (NAIL SALON, UNIT P36). SCOPE INCLUDES ADDING NEW LIGHTS TO PANEL 'A'.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49033	18041-20000-06687	13618 W VAUGHN ST	91340	7	210B157    23	2523004045	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.27647	-118.42936	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49034	13041-10000-01671	3525 W 8TH ST #208	90005	10	132B193   572	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.05782	-118.30714	TENANT IMPROVEMENT IN EXISTING  COMMERCIAL SPACE-OX PIZZAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49035	10041-30000-06429	2049 S CENTURY PARK EAST 22nd FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	04/19/2010 12:00:00 AM		Permit Finaled	07/07/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check T-24 Energy (general/emergency) lighting on 22nd floor in high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49036	15041-10002-33436	4929-4931 N LANKERSHIM BLVD	91601	2	168B173    66	2353017001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.1605	-118.3723	02/18/2016Changes to an approved set of plans note changes on Delta 2. Scope of work includes new lighting. Scope of work includes the change of the lighting layout and revision of T-24 calculation.  Total sq. ft.  2109.  ((10-9-2015 PLAN CHECK FOR POWER. THIS IS A PLAN CHECK ONLY APPLICATION))(((PLAN CHECK FOR ENERGY ONLY FOR NEW RESTAURANT. PERMIT HAS BEEN PULLED UNDER APPLICATION: 15041-30000-30876. PLAN CHECK ONLY APPLCIATION)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49037	17041-10000-41607	4557 W ROSEWOOD AVE	90004	13	141B193  1357	5521019005	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Apartment			11/16/2017 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	34.07911	-118.3037	FULL PC FOR POWER AND ENERGY FOR A NEW 2-STORY  8-UNIT  APARTMENTS WITH ONE LEVEL OF MEZZANINE AND ONE LEVEL OF SUBTERRANEAN PARKING. SCOPE INCLUDES A NEW 600A 120/240V 3 PHASE 4 WIRE SERVICE, NEW PANELS, AND NEW LIGHTS(4 TYPICAL PANELBOARDS). TOTAL AFFECTED AREA IS 7180 SQ. FT. B#16010-10000-05771	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49038	15041-10001-16863	10638 N VARIEL AVE	91311	12	207B105   284	2706018029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM			PC Approved	08/28/2015 12:00:00 AM	ADDRESS	34.26369	-118.5928	EXPRDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTAALL 13.08 KW DC ROOF -MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(40) MODULES:SUNPOWER SPR327NE-WHT-D(2) INVERTER: ABB PVI-6000-OUTD-US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49039	15041-20001-00688	11954 N SALEM DR	91344	12	216B133   361	2606021026	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/20/2015 12:00:00 AM	ADDRESS	34.28787	-118.50669	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. Using 300W power optimizers.30  235/250W pv modules across 2 strings (15+15).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49040	19041-20000-53004	936 N LA CIENEGA BLVD	90069	5	144B173   286	5529006046	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.08792	-118.37624	TENANT IMPROVEMENT ADD NEW LIGHTS AND RECEPTACLES. PLAN CHECK FOR TITLE-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49041	16041-20000-19177	17047 W LASSEN ST	91325	12	201B133   131	2694008033	(T)RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.25042	-118.50396	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49042	13041-20000-29545	3809 S GRAND VIEW BLVD	90066	11	114B157  1475	4235023001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/17/2016 12:00:00 AM	ADDRESS	34.00441	-118.43106	T24 FOR EXISTING RESTAURANT. REPLACING 3 FIXTURES.EXISTING PERMIT 14041-90000-06978	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49043	14041-20001-25458	21301 W BURBANK BLVD 5TH FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.17351	-118.59524	[[[[11/12/14  CHANGES TO APPROVED SET OF PLANS. CHANGES HAVE BEEN CLOUDED. NO DELTA DESIGNATION PROVIDED.]]]]]TI FOR FULL 5TH FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49044	19041-10000-04327	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Issued	05/06/2019 12:00:00 AM	ADDRESS	34.04804	-118.46227	T24 PLAN CHECK FOR EXISTING COMMERCIAL BUILDING, TOTAL SQUARE FOOTAGE = 4,831 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49045	15041-20000-06441	15429 W VINCENNES ST	91343	7	198B145   102	2656016004	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.24099	-118.46877	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (28) modules, and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49046	19041-20000-08888	6606 N VARIEL AVE	91303	3	180B105    44	2148029009	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Closed	08/20/2021 12:00:00 AM	ADDRESS	34.19029	-118.59257	temporary power 800 amps for construction site.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49047	19041-10000-03687	12740 W ARROYO ST	91342	7	219B161   249	2525027014	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.29585	-118.41002	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49048	17041-10000-27969	23516 W CANZONET ST	91367	3	171B093   370	2044019012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.16555	-118.63928	8.64 kw solar system (24) AC modules, (1) 100A combiner panel, (1) 60 AC Disconnect, (1) Snnpower monitoring. Roof mounted.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49049	11041-20001-09507	20720 W MARILLA ST	91311	12	201B109   178	2748004046	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.24798	-118.58532	consolidate 200a and 400 amps services into one 600 amps with few relocation of branch circuits	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49050	12041-10000-10856	8701 S BELLANCA AVE	90045	11	096B169   683	4125016031	MR1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	33.95858	-118.38067	POWER AND ENERGY FOR EXISTING OFFICE/WAREHOUSE TI. MORE THAN 400A INSTALLED LOAD   ((((Permit for 78 circuits was paid on12041-10001-10856))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49051	10041-10000-17634	401 N LA CIENEGA BLVD	90048	5	141B173  1372	4337009001	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.07877	-118.37677	Ti for a restaurant. Plan check for power and energy.   (PARTIAL PERMIT,  EXISTING PERMIT # 10041-30000-23442.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49052	15041-20000-05762	777 N SARBONNE ROAD	90077	5	141B149    67	4370003014	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	11/25/2020 12:00:00 AM	ADDRESS	34.0845	-118.45039	Plan check for power and Title 24 (energy).  Installation of new electrical distribution equipment in single family dwelling.  New 1000 A switchgear with 7 subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49053	14041-20000-14538	5112 E ITHACA AVE	90032	14	138A233   204	5216025034	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Expired	07/15/2016 12:00:00 AM	ADDRESS	34.07223	-118.17528	3.4 Kw PV1 roof-mounted system with (12) Sunpower modules( E-20-327), and one Sunny Boy transformerless inverter ( 4000-TL-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49054	15041-20000-25341	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.20696	-118.3417	Plan check for replace fire alarm panel. Existing fire alarm divices and smoke detectors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49055	14041-20004-35577	706-720 N CAHUENGA BLVD	90038	13	141B185   537	5533032014	C4-1XL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.08371	-118.32861	2.11.2015 - Plan check for changes to approved set. Relocate connection of INV2 and INV2A from board MS to panel HP. Add disconnects for both INV1 and INV2. Changes clouded.[[[2/3/16  CHANGES TO APPROVED SET. ADDITION OF INV1A AND INV2A  INVERTERS.]]]11/17/15  changes to approve set. all changes made under delta 8. Scope includes adding site lighting. (((TI TO AN EXISTING COMMERCIAL 2 STORY BUILDING.  ADDING CIRCUITS TO EXISTINF PANELS, NEW LIGHTING AND CONTROLS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 27248.FEES ARE ESTIMATED PLAN CHECKER TO VERIFY.  CORE AND SHELL RENOVATION OF EXISTING STORE W/AXILLARY OFFICE, MANUFACTURING AND STORAGE TO OFFICE USE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49056	17041-20000-19507	9951 N MEMORY PARK AVE	91345	7	201B145    36	2660011031	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.25154	-118.46425	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (38) modules, (19) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49057	19041-10000-51749	8767 N PARTHENIA PL	91343	6	195B145   445	2654012026	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Apartment			12/16/2019 12:00:00 AM	03/28/2023 12:00:00 AM		Issued	03/28/2023 12:00:00 AM	ADDRESS	34.22923	-118.4666	FULL PC FOR NEW 73-UNIT 100% APARTMENT BUILDING. BUILDING IS 4 STORIES ABOVE GRADE. SERVICE SIZE IS 2000A,208/120V,3PH,4W. SCOPE INCLUDES DISTRIBUTION BOARDS, HOUSE PANELS, ELEVATOR MOTORS, UNIT PANELS, CICUITS, LIGHTING AND LIGHTING CONTROLS AND T-24 ENERGY COMPLIANCE FORMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49058	18041-10000-44956	2759 W ROWENA AVE	90039	4	151-5A207 179	5434031901	C4-1D	Central	Hollywood	Silver Lake	YES	1882.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.10747	-118.26373	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49059	12041-20000-10585	3680 S KEYSTONE AVE	90034	11	120B161  1178	4314009020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.02	Electrical	Electrical	Apartment			05/09/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.02189	-118.4079	New 12 unit apartment building. Fire alarm variance on file. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49060	17041-20001-01583	23000 W HARTLAND ST	91307	12	183B097   775	2026010001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM			PC Approved	01/23/2017 12:00:00 AM	ADDRESS	34.19447	-118.62847	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR. ADDITION TO EXISTING PV SYSTEM. ADDITION: 2.28 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49061	18041-20000-42874	8426 N SUNLAND BLVD	91352	6	192B177   217	2404023014	(Q)C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.22351	-118.3653	Plan check for power and energy. Project site is a existing tenant space in a commercial building. Project scope is a change of use from retail to medical office. Total lighting area = 1,421 sq. ft.Note: Building permit has been issued under 18016-20000-18325	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49062	18041-20000-19792	10517 N DES MOINES AVE	91326	12	207B117   427	2728006018	RE11-1	North Valley	Northridge	Northridge West	Yes	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.26103	-118.55583	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 11.4KVA SYSTEM CONSISTING OF 40 MODULES(WITH P320 OPTIMIZERS) AND CENTRAL INVERTER(SE11400A-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49063	11041-10000-08274	916 N WESTERN AVE	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	06/24/2011 12:00:00 AM	ADDRESS	33.75076	-118.30886	T.I.  EXISTING RETAIL SPACE.  ADDING DEVORATIVE AND CORRIDOR LIGHTING ALONG WITH REPLACING GARAGE LIGHTING.  TITLE 24 PLAN CHECK ONLY (APPLICATION ONE OF 2, PARKING LIGHTING IS UNDER SEPARATE APPLICATION 11041-10000-08268)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49064	14041-10000-04563	777 E 12TH ST #1-15	90021	14	123A211    59	5132010036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.03264	-118.25093	"PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 350 SQFT. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49065	13041-10000-22643	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	REPLACE STEAM EQUIPMENT THAT WAS DEMO'D WITH BUILDING. BUILDING UNDER SEPERATE PERMIT. METHANE ZONE. NEW PANEL. CLASSIFIED AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49066	16041-10002-10058	1635 N CAHUENGA BLVD 6TH FLR	90028	13	148-5A187 221	5546007028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.10071	-118.32971	PC FOR TITLE 24, PERMIT WILL BE UNDER MASTER APPLICATION.NEW DELTA INCLUDES CHANGES TO LIGHT FIXTURES AND ADDTIONAL UPS  PANEL. ***********************************************************************************This is Pc pC only for T-24, permit under the master E#,  Revise lighting fixtures and layout due to architectural change.  All changes noted under Delta-1<<T-24 FOR A TI IN AN (E) OFFICE BUILDING ON THE 6TH FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 7500. >>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49067	19041-20000-26618	23256 W MOBILE ST	91307	12	180B093   713	2036007017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.18804	-118.63287	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.64KW DC/3.84KW AC. SCOPE OF WORK INCLUDES (16) SOLAR WORLD PV MODULES WITH ENPHASE IQ7 MICROINVERTERS, AND A ENPHASE COMBINER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49068	17041-10002-16662	8500 W BEVERLY BLVD 629	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	12/15/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR REVISIONS  TO APPROVED SET UNDER DELTA 11 ONLY!SCOPE INCLUDES ADDING NEW EXHUST FANS PER INSPECTION. TOTAL CONNECTED LOAD <400A. INCLUDING NEW CIRCUITS AND EQUIPMENNT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49069	16041-10000-32725	10960 W WILSHIRE BLVD 8th flr	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	BATHROOM UPGRADES. PC FOR T24 ENERGY ONLY FOR NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49070	17041-20002-03636	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022058	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	34.21384	-118.44905	4/26/2018Revisions to approved set.  Changes noted delta G.  Revision of feeder schedule and associated feeder voltage drop and fault current calculations.  (((2/27/2018changes to an approved set of plans. changes noted delta D E F.  changes include revision of equipment/floor lay-out and circuits.  no additional load.  this is plan check only.    New 6-story commerical building gymnasium and parking (3 levels fitness center with 3 levels parking).  Underground 3000A 208V 3ph-4w service.  176,784 sq ft.  Plan check for power and energy.  Electrical permit has been issued under 15041-10000-28641 under previous design (same engineer).  Full resubmittal due to extensive scope of work changes - from 2000A to 3000A service, complete system redesign.)))Building permit under 13010-10000-04552.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49071	16041-10001-44428	12414 W EXPOSITION BLVD	90064	11	123B149   857	4259026002	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			PC Approved	10/21/2019 12:00:00 AM	ADDRESS	34.03061	-118.45624	CHANGES TO APPROVED SET, SCOPE OF WORK IS REMOVAL SCOPE OF WORK AND REVISIONS TO T24. ALL CHANGES ARE CLOUDED. PLAN CHECK ONLY, PERMIT COVERED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49072	16041-10000-16401	611 E SANTA CLARA AVE	90291	11	108B145   803	4239025049	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	33.99267	-118.46628	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.2KWdc / 3.0KWac.(8)MODULES-QCELL Q.PLUS-G3 275(1)INVERTER-SMA 3000 TL-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49073	14041-10000-15153	1327 E 15TH ST STE A	90021	14	121-5A213 148	5130011035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.02678	-118.24703	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 5404 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49074	18041-20000-37112	15900 W VALLEYVIEW CT 15012 A,B,-C	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.30584	-118.47951	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49075	17041-10000-45235	87 S FREMONT PL	90005	4	132B185   621	5090016008	RE11-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.05658	-118.32867	PC FOR ROOF MOUNTED PV ON SFD. TOTAL SYSTEM  SIZE 10.44KWACSYSTEM INCLUDES 36 PANELS WITH MICRO INVERTERS. PLAN CHECKER TO VERIFY SPLIT BUS AND VARIANCE IF APPLICABLE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49076	16041-10000-42012	1600 S FIGUEROA ST	90015	14	124-5A205  26	5134008003	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.03733	-118.26993	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 21975 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49077	11041-10000-03229	1240 S MENLO AVE	90006	1	129B197   982	5076019023	C2-1, R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			02/18/2011 12:00:00 AM	09/28/2011 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	34.0479	-118.29052	NEW 60 UNIT, 4 STORY PLUS 2 LEVELS OF GARAGE BELOW GRADE APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49078	16041-20000-21249	10360 W DIAMOND ST LOT 21	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49079	17041-10002-33864	24904 S PRESIDENT AVE	90710	15	039B193   667	7439026005	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	33.79859	-118.30398	03-21-2018 Changes to an approved set of plan. Changes include change PV inverter ratting from PVI-3.0-OUTD-S TO PVI-3.6-OUTD-S. Changes apply to delta B only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49080	15041-20000-35560	8107 W MCKIM CT	90046	4	153B173   944	5569032049	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Issued	10/23/2015 12:00:00 AM	ADDRESS	34.11131	-118.37046	Plan check for PV roof mounted system. System size: 5.0kW with 20 modules and 1 inverter (5.0). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49081	15041-20000-07600	21700 W OXNARD ST Suite 1200	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.17901	-118.60179	Title 24 plan check only.  Total area = 612 sq. ft.T.I. to existing office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49082	17041-10000-30926	4755 S ALLA ROAD	90292	11	105B157   549	4212007006	P-1, [Q]MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	33.9835	-118.43032	PC FOR T24 ENERGY ONLY. REVIEW LIGHITNG ALTERATION IN GENERAL COMMERCIAL WORKSPACE. MOST LIGHTING TO REMAIN. ADDITIONAL LIGHTING IN SOME AREAS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49083	17041-10000-36041	767 S ALAMEDA ST 6th floor	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	TITLE 24 PLAN CHECK FOR TI WITHIN EXISTING BUILDING - PROJECT IS COMPRISED OF EXIT ACCESS AND NEW TENANT DEMISING WALLS ON LEVEL 6 OF AN EXISTING TYPE 1A 7 STORY BUILDING; INTERIOR ALTERATION ONLY - TOTAL AFFECTED AREA = 2486 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49084	19041-20000-51598	13028 W HARTSOOK ST	91423	4	171B161   705	2358029013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.16385	-118.4169	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 6.6 KW DC/7.6 KW AC. SCOPE OF WORK CONSISTS OF (20) PV MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49085	09041-10001-05355	9480 W READCREST DR	90210	4	147B165   347	4352010046	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2010 12:00:00 AM			PC Info Complete	01/25/2010 12:00:00 AM	ADDRESS	34.09824	-118.40466	Plan check power for new electrical system with new 600A service, eeuipment, panels, and circuits for single family dwelling.((((((((((((((((((((((( Previosly three feeders E,F,G were fed from mau=in service panel. Now panel E, F are fed from panel G and total load decreased by about 45 amps. due to reduction of lights. 1-25-10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49086	14041-20000-14192	9960 N LARAMIE AVE	91311	12	204B113   689	2741013010	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.25197	-118.57317	pv1 single family. total system size 3.8kw AC using transformerless inverter. nonstandard plan. using power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49087	11041-20000-24448	8220 N REMMET AVE	91304	3	189B105    28	2110003040	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	11/05/2012 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.21824	-118.60014	Install new OPTIONAL STANDBY GENERATOR (500 KVA / 601 FLA)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49088	16041-10001-27194	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.97954	-118.41361	03-30-2017 Changes to an approved set of plans. Changes include revised lighting, power, egress lighting  and Title 24 calculation plan in pediatrics area. Additional circuits has been added.  Changes apply to delta PR-04 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49089	19041-10000-37637	3456 W OLYMPIC BLVD	90019	10	129B189   255	5081026036	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	03/21/2021 12:00:00 AM	ADDRESS	34.05232	-118.31379	New Fire Alarm System in a Mixed Use Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49090	18041-20001-45098	1520 N AMALFI DR	90272	11	132B133   153	4425021020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	34.0581	-118.50418	Expedite per applicant requestPlan check for PV roof mounted system, system size: 20.88kW DC, 18.619kW AC with 58 AC Modules connected to 400A panel, 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49091	15041-10000-24913	624 W 190TH ST	90248	15	060B201    98	6121022903	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		5435.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	33.86082	-118.28564	PLAN CHECK FOR POWER FOR REPLACEMENT OF GENERATOR IN HAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49092	15041-20000-38988	10100 N GLADBECK AVE	91324	12	204B121   443	2729012015	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Expired	12/21/2017 12:00:00 AM	ADDRESS	34.2535	-118.53911	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5KWac. (23) MODULES-KYOCERA #KU2566ZPA(1) INVERTER- ABB# PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49093	11041-20001-00924	8420 N LANKERSHIM BLVD	91352	6	192B169   383	2632022002	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM			PC Approved	05/19/2011 12:00:00 AM	ADDRESS	34.22367	-118.38757	Changes from previously approved.  Changes in lighting switching location.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49094	11041-10000-10198	2225 S SAN PEDRO ST	90011	9	120A209    53	5127007013	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	34.02438	-118.25972	PER DWP'S REQUEST, REPLACING SERVICE DROP CONDUCTORS WITH ALUMINUM CONDUCTORS AS THE ORIGINAL COPPER CONDUCTORS WERE VANDILISED;  THE ELECTRICAL INSTALLATION REMAINED THE SAME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49095	17041-20000-35671	18019 W VENTURA BLVD	91316	10	138B193  1029	5517009034	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.16485	-118.52493	permit fee $0.00 by state senate bill no.1222pv2install roof mounted pv system sized 60kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49096	13041-10002-33210	1133 N VINE ST	90038	13	144B185   591	5533007023	[Q]C2-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.09171	-118.32698	10/13/16Changes to an approved set of plans. All changes are clouded under delta B. Changes include relocating loads on panel shedules, removing distribution boards, and reconnection feeder panels to main service distribution board; replacing feeder conductors from copper to aluminum MC cables, and revising fault current values on feeder panels. ((((((PLAN CHECK FOR POWER AND ENERGY.DESCRIPTION FROM BUILDIN DEPARTMENT: 5 STORY, 112 ROOM HOTEL WITH 1 LEVEL OF UNDERGROUND PARKING (TYPE I-A GARAGE & TYPE V-A RESIDENTIAL ABOVE)  SEE COMMENTS...	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49097	17041-10000-27366	9115 N WOODMAN AVE	91331	6	198B153   937	2639031012	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.2358	-118.44103	REPLACE EXISTING FIXTURES WITH LED FICTURES- T24 ONLY. TOTAL SQUARE FOOT 15250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49098	18041-10001-18137	2714 S FORRESTER DR	90064	5	126B165   197	4308006019	R1V2-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.04379	-118.40398	Adding additional AC disconnect on the floor plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49099	11041-10000-03907	20901 W SHERMAN WAY	91303	3	183B109    58	2112017001	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.20126	-118.58873	TI WORK ON A NEW RESTAURANT, PREVIOUSLY TWO SEPERATE RESTAURANT.  NEW PANELS, CIRCUITS, AND EQUIPMENT.  FULL PLAN CHECK.  SINGLE STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49100	12041-20000-12136	7834 N VANSCOY AVE	91605	2	189B161   779	2308013009	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2012 12:00:00 AM			PC Info Complete	08/09/2012 12:00:00 AM	ADDRESS	34.2128	-118.40649	Photovoltaic system on roof of single family dwelling using enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49101	13041-10000-29902	801 E COMMERCIAL ST	90012	14	130-5A217 174	5173019006	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.05272	-118.231	TITLE 24 PART 6 ENERGY FOR OUTDOOR LIGHTING IN EXISTING COMMERCIAL BUILDING. SCOPE OF WORK IS <400A, AND INCLUDES INSTALLING 23 OUTDOOR LIGHTING FOR BUILDING FACADE. TOTAL ILLUMINATED AREA IS 30,378 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49102	11041-10000-09166	7060 W HOLLYWOOD BLVD	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Closed	11/23/2011 12:00:00 AM	ADDRESS	34.10137	-118.34379	NEW RESTAURANT IN EXISTING RETAIL SPACE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49103	13041-20000-27564	11507 W OXNARD ST	91606	2	177B169   797	2338004001	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.1796	-118.38271	NEW FIRE ALARM SYSTEM FOR EXISTING OFFICE SPACE. 35 DEVICES AND 1 NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49104	19041-10000-24942	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Issued	07/03/2019 12:00:00 AM	ADDRESS	34.06281	-118.2731	T-24 PLAN CHECK FOR A TI TO AN EXISTING MEDICAL OFFICE. SCOPE OF WORK IS LIMITED TO FIRST FLOOR LOBBY AND CONSTRUCTION OF ACCESSIBLE RESTROOMS.B# 19016-10000-13502	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49105	17041-10000-42242	568 E DENNI ST	90744	15	033B209   712	7423025015	[Q]R2-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	33.78489	-118.25593	PV1 3.0kw roofmounted system with (9) modules and (1) inverter directly connected to the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49106	13041-10000-08381	1041 S GLENDON AVE 1-115	90024	5	132B153  1097	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.06187	-118.44447	13041-10000-08381T24 FOR CHANGE OF USE FROM RETAIL TO HAIR SALON. NEW ADDED LOAD IS LESS THAN 400A. SQRFT: 6400. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.Home runs, circuit numbers and wire size and ci=onduit are indicated under key notes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49107	13041-20002-14127	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			PC Approved	12/10/2013 12:00:00 AM	ADDRESS	34.24143	-118.56249	(((ADDED SEPERATE SWITCHING FOR DAYLIT AREA TO COMPLY WITH T24)))Plan check power and energy for TI existing 2-story office building includes industrial area and associated labs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49108	15041-10000-16513	5901 W CENTER DR PHASE 1	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			06/10/2015 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	ADDRESS	33.97509	-118.38703	pc for power and energy. new apartment building, 5 story, 95 units. total area 60280 sq ft(unconditioned ) + 4365 sq (conditioned). PHASE 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49109	14041-10000-08573	911 S LUCERNE BLVD	90005	4	132B185   557	5090021015	R2-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	PIN	34.05748112	-118.3270089	PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(19) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49110	16041-20001-30532	9210 N DORRINGTON AVE	91331	6	198B153   744	2642027009	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.23764	-118.4363	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM . SYSTEM SIZE: 11.445 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49111	17041-30000-23588	2950 S VAN BUREN PL	90007	8	120B197   279	5054014022	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Apartment			07/13/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.02777	-118.29685	Plan check for a PV2 roof-mounted PV system. System size is 16.8 kWac and consists of (56) modules, (28)  micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49112	17041-10000-40114	3533 E SABINA ST	90023	14	121-5A227  35	5188003031	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Expired	03/06/2024 12:00:00 AM	ADDRESS	34.0284	-118.19606	PC for 3.8kW rooftop PV in SFD. Installing SE3800A-US central inverter and 10 PV panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49113	19041-10000-17739	1071 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   184	5037026025	P-1, [Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM			PC Info Complete	05/14/2019 12:00:00 AM	ADDRESS	34.01106	-118.29383	PC for T24 only to an exisiting mcdonalds, TI. Scope of work includes adding and removing fixtures. Affected area is 2190 sqft. BLDG# 19016-10000-13999	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49114	16041-10005-08351	524 E WASHINGTON BLVD	90015	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.0283	-118.25963	CHANGE TO APPROVED SET OF PLANS TO REFLECTE AS BUILT CONDITIONS. CHANGE NOTED DELTA 8 ON PLANS.SCOPE INCLUDES CHANGES IN WIRING SIZE AND QUANTITY.  ADDITINON OF PANEL AND REVIESE BREAKERS SIZE. ALSO, REMOVAL OF COMBINERS AND REPLACMENT WITH J-BOXES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49115	12041-10001-00324	7260 W MELROSE AVE	90036	5	141B181   625	5525013002	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			Corrections Issued	03/05/2012 12:00:00 AM	PIN	34.08325459	-118.3479113	TI in a spa/salon. EPC is for energy & T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49116	12041-20000-21539	458 S MAIN ST	90013	14	129A211   157	5148009015	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			PC Approved	09/11/2012 12:00:00 AM	ADDRESS	34.04683	-118.24814	T24 Planc check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49117	12041-10004-18057	630 W HARRY BRIDGES BLVD Main Bldg	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	33.77068	-118.26868	((8/19/2014 - Supp. app for changes made to approved set to reflect field changes at request of inspector.  Addition of series rated overcurrent protection device.  Changes made are marked with delta 13))Master permit scope of work: NEW ADMINISTRATION BUILDING.  EPC IS FOR POWER AND ENERGY.  FIRE ALARM IS SUBMITTED SEPARATELY.  Photovoltaic system is on supplemental application.  Building is in a Methane Zone.  Methane detection system is on a separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49118	13041-10000-31032	757 E PICO BLVD	90021	14	123A211    92	5132012018	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.03204	-118.25205	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  3860 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49119	13041-20000-22474	21650 W OXNARD ST #100	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Change to lights in 4 existing offices in a high rise building.  Plan check only for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49120	19041-10000-44817	12746 W JEFFERSON BLVD	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	06/15/2020 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	33.97756	-118.41709	[EPLAN] PLAN CHECK FOR NEW EV CHARGING STATION TO EXISTING 2 SERVICES(4000A 480/277V). INSTALL INCLUDES 14 TESLA SUPERCHARGERS, 7 TESLA CABINETS, 2 LEVEL 2 CHARGERS, (7) 160KVA TRANSFORMERS AND ASSOCIATED EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49121	11041-10001-23496	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022		West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	ADDRESS	34.08694	-118.47588	PLAN CHECK ONLY-- REVISED SINGLE LINE DIAGRAM TO SHOW THAT DISTRIBUTION BOARD IS REMOVED  AND PREVIOUS FEEDERS EDB-3,-2 THROUGH NEW PULL BOX TO CIRCUIT BREAKERS FROM THE GENERATOR; PREVIOUS  EM FEEDER EDB-1RE-ROUTE THRU EXISTING EM GUTTER TO EM PULL BOX TO CIRCUIT BREAKER FROM THE GENERATOR Plan submittal to replace expired originals approved under PCIS 10041-10000-08310, including a revision of the generator location.(Replace emergency generator from a 175Kw to 500Kw at the existing building (Getty Center).  Install new switchboard, panel, and two ATS.  Plan check for power only.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49122	17041-20000-43283	229 N BURLINGTON AVE #6	90026	13	136-5A207 286	5159006009	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM			Reviewed by Supervisor	01/12/2018 12:00:00 AM	ADDRESS	34.06717	-118.26626	plan check for power only.NEW 4 STORY SINGLE FAMILY DWELLING W/ ATTACHED GARAGE. (PART OF NEW SMALL LOT SUBDIVISION). 6 of 6 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49123	17041-20001-20755	16915 W ROSCOE BLVD	91325	12	192B133   234	2205001004	M2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM			PC Approved	09/11/2017 12:00:00 AM	ADDRESS	34.22139	-118.50174	[[9/11/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES. CHANGES ARE CLOUDED. PLANCHECK ONLY. CHANGES TO LIGHTING.]]]New addition at front of (E) 1-story animal hospital.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49124	14041-20000-01891	6923 ESTEPA DR	91042	7	198B201   107	2572031019	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	PIN	34.24176892	-118.28290574	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 24 MODULES TRANSFORMERLESS INVERTER NONSTNADARD PLAN WITH POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49125	11041-20001-00813	2707 W BEVERLY BLVD	90026	13	136-5A203  19	5156020019	C2-1	Central	Westlake	Rampart Village	YES	2086.20	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM			PC Info Complete	01/28/2011 12:00:00 AM	PIN	34.07021195	-118.27775843	Changes from previously approved plans.  Change in lighting fixture types.  Plan check for energy only.Note:  Permit is under 11041-20000-00813.*****T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49126	18041-10000-10181	711 N ALAMEDA ST	90012	14	132A215   123	5408009900	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.05492	-118.23798	PC for power only, Scope of work includes new 1000A service 120/240V, 1ph, 3W, for 5 modular builings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49127	13041-10000-08952	946 E 12TH ST	90021	14	123A211   196	5132013009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM			PC Approved	05/03/2013 12:00:00 AM	ADDRESS	34.03135	-118.24843	SINGLE STORY BUILDING.  3 RETAIL UNITS.  T24 INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49128	18041-10000-15200	1900 S AVENUE OF THE STARS 19TH Floor	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI IN AN OFFICE AREA, ON THE 19TH FLOOR OF A HIGH RISE BUILDING.T-24 ENERGY ONLY. TOTAL AREA: 19,157 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49129	18041-20000-07786	20655 W CHESTNUT CIR (#262)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.29376	-118.58446	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49130	11041-10000-17288	4343 W SLAUSON AVE	90043	8	108B181   188	5008016040	[Q]C1.5-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	33.98905	-118.35119	T.I.  Existing 7-Eleven.  Replaceing the existing light fixtures with LED light fixtures in the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49131	16041-20001-02406	7709 W FOOTHILL BLVD	91042	7	204B197   640	2558008015	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.25695	-118.3002	Expedited per customer request.PV2. System is being installed on a commercial building (medical). Install roof mounted PV system sized 5 kW. Interconnected with main service panel. (18) SolarWorld SW285 Modules(18) Solaredge P-400 Power Optimizers(1) Solaredge SE 5000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49132	18041-10000-07987	8500 W BEVERLY BLVD #788	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a retail T.I  (Space #788) ; scope includes new equipment , and new lighting. Total area is 2138-SQ feet. plan check is under Tailored method.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49133	15041-10000-20786	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	REPLACEMENT OF AIRHANDLERS ON DISTRIBUTION BOARD 3DPACA AND 3DPACB.  ADDING NEWLOAD < 400 AMPS.  PLAN CHECK REQUESTED BY APPLICANT.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49134	15041-20000-39903	1350 S ROXBURY DR	90035	5	132A165   286	4330013003	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			11/25/2015 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.05471	-118.40246	New 34 unit apartment. New 1600A service. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49135	13041-10000-00890	8556 W 3RD ST	90048	5	138B173   741	4334009027	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM			PC Approved	01/14/2013 12:00:00 AM	ADDRESS	34.07343	-118.37888	T24 PC FOR ENERGY. TI EXISTING BAKERY PER 06016-30000-29170. Per applicant, not hazardous because they do not store flour there.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49136	19041-20000-52896	970 N MONUMENT ST	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	05/03/2021 12:00:00 AM	ADDRESS	34.04646	-118.52393	Plan check for Title 24 Energy only, new lighting in the area. Total area: 558 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49137	15041-20001-09641	12682 W SANDHILL LANE 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/01/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	33.97708	-118.41507	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: SYSTEM SIZE: 1.38KW   LANE # 36 MODULES(1) 3.0 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49138	12041-10000-30499	12777 W JEFFERSON BLVD	90066	11	102B161  1158	4211009033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2676.00	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	33.9778	-118.41768	FIRE ALARM SYSTEM FOR EXISTING 2 STORY 1 BUILDING (ABC)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49139	15041-10000-36818	1833 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1-1, C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.04342	-118.37677	TI TO AN EXISTING COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD > 400 AMPS.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49140	10041-10000-17649	1201 E PLAZA DEL SOL ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	PIN	34.04979564	-118.22640016	Solar voltaic system installed on the roof of the building.  Consists of  7 modules,  7 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49141	15041-20001-43998	16654 W WYANDOTTE ST	91406	6	186B137   344	2226016009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	01/19/2016 12:00:00 AM	ADDRESS	34.20282	-118.49652	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.7 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49142	13041-10000-08954	946 E 12TH ST	90021	9	123A211   196	5132013009	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Closed	04/10/2013 12:00:00 AM	ADDRESS	34.03135	-118.24843	CONDUIT ONLY PERMIT IN REFERENCE APPLICATION NUMBER 13041-10000-02082.*****************************************************************SINGLE STORY BUILDING.  3 RETAIL UNITS.  T24 INDOOR AND OUTDOOR LIGHTING.	N	N	Express Permit	06/10/2024 12:00:00 AM
49143	18041-10000-37594	970 W 190TH ST 400	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	33.85812	-118.29302	PC FOR OFFICE TI IN A HIGHT RISE BUILDING FOR T24 ENERGY. SCOPE INCLUDES NEW LIGHTING AND CIRCUITS. TOTAL AFFECTED AREA 6357 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49144	15041-10001-14901	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Expired	05/28/2018 12:00:00 AM	ADDRESS	34.04797	-118.25815	04/13/16Changes to an approved set of plans. All changes are clouded and under delta 6. Changes include removing/adding lighting fixtures, adding smoke doors, receptacles, revising title 24 forms, and revising load calculations for panels 'MSB', and 'DP1.' Also new lights for staircase and common areas. (((((PLAN CHECK FOR POWER AND ENERGY FOR NEW GYM IN EXISTING MALL. 800A DISTRIBUTION FOR GYM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49145	09041-20001-21274	"5701 N PLATT AVE BLDG ""B"""	91367	3	174B093   222	2045024003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Info Complete	06/02/2011 12:00:00 AM	ADDRESS	34.17396	-118.64329	Plan check for revisions to approved plans only. Revisions indicated as Delta 1 on plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49146	13041-10000-02540	6530 N INDEPENDENCE AVE	91303	3	180B109   449	2148026046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Apartment			01/31/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.18916	-118.59044	Upgrade fire alarm panel for 3 story apartment complex plus adding 13 smoke detectors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49147	16041-20001-32644	3461 S GRAND VIEW BLVD	90066	11	114B153    96	4248017021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.01227	-118.43713	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of roof-mounted solar array on SFD. Interconnect with 400A split bus panel.15.2kW ungrounded system (7.6+7.6). (64) 320W pv modules. Each module has a 320W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49148	17041-20000-16856	700 S FLOWER ST ste 2380	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	ti to an existing commercial building.  adding new lighing new controls to existing panels.  plan check for energy and em lighitng.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49149	19041-30000-14956	2049 S CENTURY PARK EAST 35th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Issued	04/23/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is the elevator lobby on the 35th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 295 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49150	19041-20000-23267	10642 N BALBOA BLVD B	91344	12	207B133   597	2684001024	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Info Complete	06/18/2019 12:00:00 AM	ADDRESS	34.26355	-118.50206	TI to (E) commercial retail space.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49151	17041-10000-14950	1533 W WILSHIRE BLVD	90017	1	132A205   222	5142027016	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Issued	05/05/2017 12:00:00 AM	ADDRESS	34.05521	-118.26932	PC for energy only, Removing HID fixtures and replacing them with new LED. Area: 4,650 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49152	11041-10000-26462	7565 W BEVERLY BLVD	90036	5	138B177   410	5526041014	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.0763	-118.35487	Shell only to an Office/Dry storage/Food Distribution with at change of use to a FUTURE restaurant.  PLAN CHECK ONLY for Energy (Lighting, with Emergency lighting).  <<<<<Tenant space will require a full plan check once a tenant moves in.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49153	10041-10001-19567	11757 W CHENAULT ST	90049	11	132B145   386	4401013003	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.05511	-118.46941	NEW SINGLE FAMILY HOUSE. 2 LEVELS BELOW GRADE  (29,988 SQR FT) AND 2 LEVELS ABOVE GRADE (11,317 SQR FT).(((((((((((((((((((((((((( changes made to prviously approved set plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49154	19041-10000-46110	14312 W BERG ST	91342	7	222B153   398	2508015015	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.30443	-118.44493	NEW ROOF-TOP SOLAR INSTALLATION 5.36KWdc (3.8KWac) USING 16 QPEAK 335W MODULES, 16 SOLAREDGE P360 POWER OPTIMIZERS AND 1 SE3800H-US CENTRAL INVERTER. CONNECTED TO A 200 AMP NEW SERVICE. NEW SERVICE SHAL BE PERMITED SEPARATELY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49155	13041-20001-34228	4520 E HUNTINGTON DR NORTH	90032	14	142-5A229 296	5305035006	RD2-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM			Reviewed by Supervisor	12/19/2013 12:00:00 AM	ADDRESS	34.08413	-118.19022	EXPEDITE FEES ONLY.         <<<New 17.28kw rooftop PV system for an existing single family residence with 600 amp service.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49156	14041-10000-00076	8635 W METZ PL	90069	5	147B173   497	5559017001	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.09607	-118.37966	PLAN CHECK FOR POWER. UPGRADE OF SERVICE TO 600 AMPS.BUILDING PC# 12014-10000-01398. MAJOR RENOVATION AND ADDITION TO EXISTING SINGLE FAMILY DWELLING WITH BASEMENT. see comment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49157	16041-20003-20464	14748 W KESWICK ST	91405	6	186B149    26	2210028008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			PC Approved	08/01/2017 12:00:00 AM	ADDRESS	34.21015	-118.45472	08/01/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the distribution equipment AIC rating and some of the feeders. 7/14/17changes to an approved set of plans.  changes include updating plan to reflect field conditions.  this ia plan check only.  (((New service and build out for (E) plant cultivation building in response to code enforcement action.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49158	15041-20001-38783	4614 N WESTCHESTER DR	91364	3	168A111   107	2174012022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	ADDRESS	34.1536	-118.58228	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE : 21.582 KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49159	18041-10000-18487	22810 S FRAMPTON AVE	90501	15	045B197    56	7347018050	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	33.8185	-118.29945	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49160	12041-20000-17030	1053 S NEW HAMPSHIRE AVE	90006	10	129B197   376	5078011007	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			07/20/2012 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.05122	-118.29282	new 52 units apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49161	12041-10000-01703	10861 W WEYBURN AVE B1-B2	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.06247	-118.44344	Fire alarm system for a retail building with 256 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49162	14041-10000-30390	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.05494	-118.23752	Plan check for T24 energy only. Tenant improvment for new kiosk	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49163	17041-20002-22680	3660 W WILSHIRE BLVD	90010	10	132B193    63	5093019020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM			PC Approved	03/07/2019 12:00:00 AM	ADDRESS	34.06155	-118.30505	3/7/2019CHANGE TO APPROVED SET, CHANGE FROM 790 PHONO SOLAR 325W PV MODULES TO 765 LONGI SOLAR 345W PV MODULES.THIS IS PLAN CHECK ONLY.((((Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,052) modules, and (1) load center.Note: Permit Fees $0 due to SB 1222Note: Building application has been generated under 17014-30000-03171))))((((7/31/2018changes to an approved set of plans.  changes to decrease system size to 180KW AC.  Line side tap.this is plan check only.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49164	19041-10000-29685	14747 W ARMINTA ST	91402	6	189B149   479	2210021030	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Issued	07/31/2019 12:00:00 AM	ADDRESS	34.21379	-118.45456	INSTALL (75) FIRE ALARM DEVICES AND (1) PANEL FOR A COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49165	18041-10001-13799	7345 N MEDICAL CENTER DR	91307	12	186B093   586	2021014045	(Q)CR-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.20343	-118.62973	Supplemental plan check for power only per inspector's request, permit has been obtained online. Remove chiller pumps and Replace 175A  air cooled chiller to 296A air cooled chiller. New breaker and feeder for two chilled water pumps and vfd's. These new chillers are fed from existing MCC and the load of MCC has now been reduced from 423A to 324A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49166	15041-10002-09305	1828 S WESTERN AVE	90006	10	126B193   744	5074015051	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.04091	-118.30873	PC FOR POWER AND ENERGY REVISION TO THE APPROVED SET OF PLAN. DISAGGREGATION OF LOAD INTO TWO PANELS. CHANGEOF USE FROM LIVE/WORK TO COMMERCIALTOTAL NUMBER OF BRANCH CIRCUITS REDUCED TO 84 IN TOTAL.THIS IS NO LONGER RESIDENTIAL PLAN CHECK. ALL UNITS TO BE CHECK FOR NON RESIDENTIAL ENERGY COMPLIANCE. GREEN IS MANDATORY - REVIEW CAR CHARGER REQUIREMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49167	13041-20001-06510	1324 N BENEDICT CANYON DR PV-1	90210	5	147B157   434	4356011006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2013 12:00:00 AM			PC Approved	05/08/2013 12:00:00 AM	ADDRESS	34.09535	-118.42973	((CHANGES MADE TO PREVIOUSLY APPROVED SET OF PLANS. REROUTING CONDUIT THROUGH THE GARAGE. THIS IS A PLAN CHECK ONLY))Install a new Ground Mounted PV System for an existing single-family residence.  System uses Micro-inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49168	18041-10002-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.26056	-118.35206	PC FOR NEW ESS  TELSA POWERWALL 2 (AC)SCOPE INCLUDES TWO NEW POWERWALL 2 ESS AND NEW SUBPANELTHIS IS SUPP. TO MASTER TO INCLUDE ESS INSTALLATION WITH A PV INSTALLATION UNDER MASTER. NOTE: EXSITING SERVICE RATED AT 600A 120/240V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49169	16041-10002-01886	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	Addition of motor loads to distribution board T8-5.  Changes to floor plan layout and panel schedule.  New lighting in electrical room.  All changes clouded with delta 36.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49170	15041-10000-31498	6500 W WILSHIRE BLVD 21st - FLR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.06371	-118.3703	Energy plan check for an office (21st Floor ) T.I. Scope includes new lighting and receptacles. Total area is 2310-SQ feet. Portion of permit fee is paid under Permit # 15041-10000-29781.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49171	18041-10000-06121	11755 W EXPOSITION BLVD	90064	11	123B149   511	4260011019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.03286	-118.44853	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49172	14041-20001-02366	735 S FIGUEROA ST UNIT 139	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM			PC Approved	03/19/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	Change from previously approved plans.  Change includes reconnect emergency fixtures and exit signs to existing normal and emergency circuits.   Note: Permit is under the original application.*****PC FOR T24 ENERGY ONLY. NEW LIGHTING IN EXISTING RETAIL. TOTAL AREA 1327 SQ FT. WORK DONE FOR T-MOBIL, UNIT 120*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49173	16041-10002-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	1/4/2017CHANGES TO THE APPROVED SET OF PLAN. CHANGES UNDER ADD-006 INCLUDING RELOCATING SOME CIRCUITS AND FIXTURES AND ADDITION OF 2 MORE FIXTURES AND 8 NEW CIRCUITS.----PLAN CHECK FOR POWER AND TITLE-24BUILDING PERMIT #16016-10000-11862SCOPE OF WORK DENOTED BY DASHED AND SOLID LINES.  FACILITY IMPROVEMENT FOR TERMINAL 2 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUS OPERATION, AND OFFICE RENOVATION.  17 NEW PANELS TIED IN TO EXISTING POWER DISTRIBUTION SYSTEM WITH ASSOCIATED LIGHTING AND EQUIPMENT.-----	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49174	18041-10001-15523	1132 N GLENDALE BLVD	90026	13	139-5A207 157	5404016020	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	34.07702	-118.26071	Changes to an approved set to include the kitchen area in the scope of work. All changes are marked under delta 3. TENANT IMPROVEMENTS TO EXISTING SHELL SPACE. CHANGE OF USE FROM STORAGE TO OFFICES & CHRUCH ASSEMBLY AREA. FULL PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT # 18014-10000-02760	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49175	13041-20000-25409	13200 N LA TIERRA WAY	91342	7	225B165    19	2580018014	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.31241	-118.40371	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49176	18041-10000-14626	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.08469	-118.4849	PLANCHECK FOR T24 ENERGY. TENANT IMPROVENT. REPLACING FLUORESCENT FIXTURES WITH LED. 1572 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49177	14041-20000-24199	1800 N HIGHLAND AVE 3RD FLR	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.10436	-118.33763	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDITION OF LIGHTS USING EXISTING CIRCUITS AND PANELS.  10152 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49178	15041-20000-37580	6400 N LAUREL CANYON BLVD Suite 600	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.18693	-118.3963	Plan check for Title 24 only. Project site a suite within an existing commercial high-rise building (6th floor, Suite 600). Project scope is a tenant improvement. Total lighting area = 6,606 sq. ft.Note:  Building application has been filed under 15016-20000-20273	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49179	16041-20000-25541	10563 N AMBERWOOD LANE	91326	12	207B121   520	2728029081	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.2631	-118.54434	Plan check for PV roof mounted system. System size: 11kW with 38 modules and 38 microinverters(Enphase 280)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49180	13041-20006-03925	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.0344	-118.45642	changes to approved set of plans. changes to site lighting t24 energy only. site lighting 82000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49181	13041-10000-08897	10396 W LORENZO DR	90064	5	126B161   180	4318032008	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.04102	-118.41021	PV1 FOR 2 -STORY HOUSE.  7.5 KW AC SYSTEM SIZE.  {40 MODULES: TSM 245 PA05} {INVERTER: FRONIUS IG PLUS 7.5}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49182	14041-20000-12182	12500 N LITHUANIA DR	91344	12	219B133   289	2608021030	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.29817	-118.50736	PV1 SINGLE FAMILY. USING STANDARD PLAN. USING MICROINVERTERS ENPHASE M215. 3KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49183	16041-10000-28890	7355 W APPERSON ST	91042	7	204B197   732	2558020019	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.25608	-118.29285	Remove indoor & outdoor hid fixtures and replace with new LED fixtures. Plan check for TI-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49184	18041-20000-37033	2003 W JEFFERSON BLVD	90018	10	120B189   674	5052023038	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.02567	-118.31537	Plan check for Title 24 only in existing space T.I. art studio Total area: 4185 sq ft. B#17016-10000-22551	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49185	16041-20000-01909	19100 W NAPA ST	91324	12	192B121    83	2784007005	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.22631	-118.54949	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel. (42) Canadian Solar CS6pp Modules(1) Fronius Primo 7.6 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49186	14041-10002-28477	1043 S KINGSLEY DR	90006	10	129B193   528	5080025009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	01/12/2015 12:00:00 AM	ADDRESS	34.05133	-118.30329	expedite per customer request(((PV2, 21.1 Kw roof-mounted system including (4)Delta Solivia 5.2TL  inverters , and (88) LDK 280p-24 modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49187	16041-10000-27766	21422 W ROSCOE BLVD	91304	3	192B105   615	2110003054	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.21961	-118.59865	Remove outdoor HID fixtures and replace  with new LED fixtures - plan check T/24 only. Total area 74715 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49188	16041-20000-38586	9700 N WOODMAN AVE ste 10-a	91331	6	201B149   343	2644024025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.24599	-118.44723	ti to change of use from restaurant to medial office.  Plan check for power and energy.  total square footage 2800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49189	19041-20000-13099	6904 N VANTAGE AVE #120	91605	2	183B165   722	2321010***	(T)(Q)RD3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.19578	-118.39751	Plan check for PV roof mounted system, system size: 6.0KW with 23 PV modules and 1 inverter(6.0KW) connected to center fed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49190	19041-20000-27653	3792 N WINFORD DR	91356	5	165B125   112	2184013018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.13809	-118.55311	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM WITH ESS ON EXISTING SFD. SYSTEM SIZE IS 16.38 KW DC/15.2 KW AC. SCOPE OF WORK CONSISTS OF (52) PV MODULES, (2) SE7600 INVERTERS,  (4) 13.5 KWH POWER WALLS AND (4) SUBPANELS$0 fee due to SB1222 and AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49191	13041-10000-03015	624 S GRAND AVE 4TH FLR	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	INSTALLATION OF NEW DISTRIBUTION BOARD & NEW MOTOR LOADS ON THE 4TH FLOOR.  << THIS PERMIT WAS FINALED FOR A DIFFERENT SCOPE OF WORK. CONTRACTOR WILL BE PULLING A PERMIT UNDER SCOPE OF WORK UNDER THIS PC# 13041-10000-03015 >>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49192	17041-10000-01989	631 S MAPLE AVE 1ST STORY	90014	14	127-5A211 167	5148022011	C2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.04321	-118.24867	PC FOR CHANGE OF USE TO OFFICE SPACE. NEW PANELS, TRANSFORMERS, LIGHTING AND POWER. PC FOR POWER AND ENERGY. 2 SMALL MEDICAL ROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49193	14041-20000-11410	1347 E PALMS BLVD PV1	90291	11	111B149   258	4244028009	R1-1VLD	West Los Angeles	Venice	Venice		2731.00, 2737.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.00284	-118.45256	PV1.  Plan check only for existing residential roof-top PV system permit under 13041-10000-10553.  Change of inverter (to transformerless) and now requires plan check.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49194	16041-10003-45793	7157 WORLD WAY MSC-M/V	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM			Permit Finaled	06/04/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	Changes to an approved set of plans. All changes are clouded. Modification of circuits, aic ratings of panelboards, and revising floor plans. Applicant request Mehdi as the plan checker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49195	10041-10000-23236	10940 W WILSHIRE BLVD Suite #150	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM			PC Approved	11/19/2010 12:00:00 AM	ADDRESS	34.05822	-118.4452	TI IN AN EXISTING OFFICE AREA IN SUITE # 150. PLAN CHECK IS FOR T-24 ENERGY CALCS. PERMIT WAS ISSUED UNDER 10041-90000-22044.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49196	11041-20000-26290	127 S SAN VICENTE BLVD Bulletin-110CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM			PC Approved	12/09/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION  Bulletin #110CS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49197	18041-20000-04589	1038 S CARMELINA AVE	90049	11	126B145   207	4264021026	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.04351	-118.47214	Plan check for the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49198	13041-10000-06738	11787 N GLADSTONE AVE	91342	7	213B165   102	2531032052	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1042.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2013 12:00:00 AM	03/15/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.28403	-118.3996	SINGLE FAMILY DWELLING, TOTAL SYSTEM SIZE 3.672KW. MICROINVERTER STANDARD PLAN USING ENPHASE M216. TOTAL OF 17 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49199	17041-10000-08299	8421 W MELROSE PL	90069	5	141B173   443	5528002040	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	PIN	34.0838208	-118.3739021	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2966 SQ. FT. b#17016-40000-06140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49200	18041-10000-08246	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.04338	-118.26581	PC FOR OFFICE TI FOR EXISTING SUITE FOR TITLE 24 ENERGY ONLY. INSTALLING NEW LIGHTS ( ALL EXISTING CIRCUITS) AND RECEPTACLES.TOTAL AFFECTED AREA 1300 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49201	17041-10002-07322	2005 S MAGNOLIA AVE	90007	1	126B197  1080	5056029005	[Q]R4-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.0379	-118.28736	Plan check for a lost of plan, original plan is under 17041-30000-07322 ( PV1 roof-mounted PV system with a size of 11.4 kWac and consists of (1) inverter and (36) modules.) The application is for plan check only. All permit fee is paid under original application number.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49202	14041-20000-12043	12655 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97753	-118.41457	pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #3. 3/3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49203	13041-10000-12124	500 S CENTRAL AVE	90013	14	126A215    61	5147014005	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	05/17/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.04092	-118.23969	THIS IS A OLD WARE HOUSE  ADDITION OF 350 KW GEN SET. TITLE  24 FOR GEN SET ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49204	19041-20000-30138	19022 W HARTLAND ST	91335	3	183B121  1026	2129025007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.19463	-118.54796	Installation of a 13.5 kWh energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49205	13041-20000-22450	16167 W ROYAL OAK ROAD	91436	5	162B141   175	2286013008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.14143	-118.48363	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 27KW AC. ROOF MOUNTED. TOTAL OF 90 MODULES. USING TRANSFORMERLESS INVETER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49206	17041-10000-04284	1907 S ARLINGTON AVE	90018	10	126B189   941	5060031025	[Q]CM-1VL-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.03943	-118.31792	PC for outdoor Title 24 only. Removing HID fixtures and replacing them with  new LED ones. Area: 15,450.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49207	18041-20000-32923	777 S FIGUEROA ST 51ST FLR.	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only in existing space high-rise building on 51st Floor Office T.I. Total area: 14,640 sq ft. B18016-10000-27043	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49208	13041-10001-30824	10326 N ORO VISTA AVE	91040	7	204B189   442	2560013009	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/27/2013 12:00:00 AM	ADDRESS	34.2569	-118.31562	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 2.75 KW.(11) TRINA SOLAR # TSM-250PA05.18(11) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49209	18041-10002-06636	947 S TIVERTON AVE 1-494	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM			PC Approved	07/29/2019 12:00:00 AM	ADDRESS	34.06246	-118.44303	(This is plan check only, permit is covered under master# 18041-10000-06636) Change to approved set by changing all copper feeder to aluminum in the single line diagram. voltage drop and fault current also being updated. All changes are under delta-4 only. Note, design engineer also being changed; an authorized letter will be provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49210	19041-10001-32026	110 E 9TH ST 5TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLAN CHECK ONLY. CHANGES TO APPROVED SET TO REMOVE ALL TRACK LIGHTING. T-24 IS UPDATED ACCORDINGLY. ALL CHANGES ARE CLOUDED UNDER DELTA 1.. ((((Energy plan check for a partial office T.I located on the 5th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 18,931-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49211	17041-10000-40708	10717 S HICKORY ST	90059	15	088-5A215  17	6068002027	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	33.93838	-118.23598	PC for 3kW rooftop PV solar. Installing 15 modules with optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49212	16041-10000-04577	10250 W CONSTELLATION BLVD SUITE 2900	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	T-24, INTERIOR TENANT IMPROVEMENT TO A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3723	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49213	19041-10000-41703	1519 W VENICE BLVD	90006	1	126B197   128	5056006017	CM-1-CPIO	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.0444	-118.28731	T-24 PLAN CHECK FOR A TI TO A PORTION OF AN EXISTING BAKERY (KITCHEN AND RESTROOMS).SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA 315 SQ.FTB#19016-10000-26512	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49214	14041-20001-16949	11620 W WILSHIRE BLVD 10th floor	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM			PC Approved	11/25/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	11.25.2014 - Plan check for modifications to approved set. Title 24 only. Delta 1 changes. 2 fixtures changed, lighting plan and title-24 forms updated to reflect this.[pc for title 24 energy and emergency only.  existing high rise building. new lighting fixtures on the tenth floor all circuits are existing, no new loads.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49215	18041-10000-22577	333 S HOPE ST 32ND FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Power and Energy on (E) office. TI with new loads > 400A, total area: 22,907 sq.ft. 32nd floor.(B# 18016-10000-18244)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49216	15041-20001-36737	20700 W KINGSBURY ST	91311	12	207B109   432	2706011039	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM			PC Approved	11/09/2015 12:00:00 AM	ADDRESS	34.26339	-118.58452	Expedite fees per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (2) inverters, (29) modules, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49217	14041-20000-23973	6626 N MURIETTA AVE	91405	2	180B153   457	2238003027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.19119	-118.43876	PV1STANDARD PLAN CENTRAL/STRING INVERTER.SIZED 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49218	14041-20000-06887	11601 W WILSHIRE BLVD 11TH FLOOR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	T24 FOR EXISTING  HIGHRISE OFFICE BUILDING. SCOPE OF WORK IS ON THE 11TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49219	18041-10000-04588	6350 W 3RD ST	90036	4	138B177   796	5509018009	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.07119	-118.36054	PC for T24 only for new lighting in food bar area. Replacing existing track lights with new led lights. Installing new receptacles and equipment. Connected load under 400A. Total area is 1392sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49220	17041-10001-34428	2900 W TEMPLE ST	90026	13	138A203    79	5156016027	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	ADDRESS	34.07395	-118.2787	PC FOR CHANGES TO APPROVED SET PER FIELD INSTALLATION UNDER DELTA 1 ONLY!SCOPE INCLUDES NEW ROOF LAYOUT FOR STRINGING. THIS IS PLAN CHECK ONLY!NOTE FEES ARE $0 DUE TO SENATE BILL 1222.PC FOR PV SYSTEM. TOTAL OF 136 MODULES AND 2 CENTRAL INVERTERS. SYSTEM RATED 40KW AC. SYSTEM USES POWER OPTIMIZERS. NET METER. CONNECTING TO EXISTING SERVICE AHEAD OF MAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49221	19041-10000-18265	5400 W VENICE BLVD	90019	10	126B177   346	5064008027	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			Corrections Issued	06/10/2019 12:00:00 AM	ADDRESS	34.04384	-118.35767	FULL PC PWR AND ENERGY FOR NEW 2nd-STORY ADDITION TO EXISTING FOOD COMMISARY BUILDING, UPGRADE SERVICE TO 600A, NEW OFFICE SPACE , AND INT REMODEL OF EXISTING FIRST FLOOR. 2-NEW CAR LIFTS. AREA OF SCOPE IS 2,577SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49222	11041-10000-16398	12302 W EXPOSITION BLVD	90064	11	123B149   794	4259027001	M1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	09/20/2011 12:00:00 AM		Permit Finaled	03/05/2012 12:00:00 AM	ADDRESS	34.03091	-118.45489	TI IN AN EXITING 1-STORY OFFICE BUILDING. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49223	13041-10000-15804	20520 W NORDHOFF ST	91306	3	195B109    72	2780001050	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	PIN	34.23141269	-118.58091638	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. SINGLE STORY STORAGE AND MANUFACTURING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49224	10041-20000-23574	14622 W VENTURA BLVD # 104	91403	5	166-5A151 118	2276002066	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.01	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	34.15125	-118.45177	bundt cake bakery	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49225	17041-10001-16662	8500 W BEVERLY BLVD 629	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	12/15/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	"REVISIONS ( DELTA8 8 & 9) TO PERMITTED SET OF PLANSLISTS OF CHANGES ARE ATTACHED TO THE PLANS((((((((((((PC FOR TI  ""ZARA"" RETAIL POWER AND ENERGY. TOTAL CONNECTED LOAD >400A.TOTAL AFFECTED AREA 26841 SQ.FT. SCOPE INCLUDES NEW SWITCH BOARDS, PANELS AND CIRCUITS.BL#17016-1000-12851"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49226	13041-10000-16281	366 E 2ND ST	90012	14	129A215   135	5161020028	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM			PC Approved	06/19/2013 12:00:00 AM	ADDRESS	34.04794	-118.23998	permit to be pulled at EPC counter only. see inspection for permit fees. TI FOR EXISTING RESTAURANT. PC FOR ENERGY ONLY. emergency lighting . less than 400A per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49227	10041-10002-15129	20801 W RINALDI ST	91311	12	210B109   548	2706007024		North Valley			YES	1131.01	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	34.27025	-118.58647	luminaires located in the upper floor have been changed from metal halide to fluorscent -less wattage and using the same circuits; title 24 forms have been revised to show the changes)))))))))New gymnasium building.  New service, switchboard, panels, and branch circuits.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49228	18041-20000-04352	6701 S CENTER DR WEST ste 425	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	33.97907	-118.39369	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for indoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49229	16041-10001-25383	700 S FLOWER ST # 2340	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	CONNECT TO GENERATOR. DELTA 2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49230	15041-20000-18149	22950 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.18618	-118.62651	TI to existing commerical building (retail). Plan check for energy only. Adding new lighting including emergency. Total sqft.  12,924.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49231	16041-30000-08988	6014 N EL CANON AVE	91367	3	177B089   549	2045004013	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.18015	-118.65333	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10.14 KW.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49232	19041-10000-05407	422 W 92ND ST	90003	8	094-5A201 225	6039004031	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	33.95266	-118.28114	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL BUILDING. TOTAL SYSTEM SIZE IS 9.00KWdc / 8.00KWac. (25)AC MODULES -SUNPOWER SPR-X22-360-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49233	14041-10002-12416	525 S HEWITT ST	90013	14	126A215    76	5163023900	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.04076	-118.2351	Delta 7 Revisions to permitted set of plans:Sheet 2.11- relocated outletsSheet 3.11- Revised lighting wireSheet 5.00- removed some outlets	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49234	14041-20000-33212	16030 W VENTURA BLVD	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.15598	-118.48247	Plan check for energy only. TI to existing office on 2nd floor of high-rise office building. New receptacles and lighting (incl. emergency). 5,690sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49235	18041-10001-27394	7267 W MELROSE AVE	90046	5	141B181   541	5525012013	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM			PC Approved	09/16/2019 12:00:00 AM	ADDRESS	34.08365	-118.34807	PC FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES ADDING ONE ADDITIONAL FIXTURE TO THE LIGHTING LAYOUT, T24 FORMS HAVE BEEN UPDATED. PERMIT HAS BEEN PULLED UNDER 18041-10000-27394	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49236	16041-10000-17725	313 W 8TH ST	90014	14	127-5A209  91	5144014026	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.0442	-118.25506	Core & Shell of (E) Retail facility due to Fire damaged. 600A service 240V,3-phase, Delta. **Note: TI portion of this project is under separate PCAM (E16LA01933).B# 16016-10000-08743 (core&shell), 16016-10000-11439 (TI).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49237	12041-10001-16077	8500 W BURTON WAY	90048	5	138B173  1321	4334016086	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	Plan check only. Original plans lost. Plan check for installation of new roof mounted 43.3KW AC CEC photovoltaic system. Apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49238	16041-20000-36504	7052 N MAMMOTH AVE	91405	2	183B157   260	2216026002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.19912	-118.43228	PV1. Install (11,180kW) PV roof mounted system with microinverters (52) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49239	17041-20000-35658	550 S SERRANO AVE	90020	10	135B193   820	5503021025	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.06398	-118.30642	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.32 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49240	11041-10000-15978	4201 S CENTRAL AVE	90011	9	114A209    92	5115019908	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Apartment			07/29/2011 12:00:00 AM			Verifications in Progress	11/30/2012 12:00:00 AM	ADDRESS	34.00745	-118.25669	Converting 2 apartment units into 3 apartment units.  A variance has been filed for a separate fire alarm.  Full plan check.NOTE TO PLAN CHECKER:  Client did not provide single lne diagram when submitting plans.  Applicant requested I charge the three panels without consulting single line.  Verify fees during plan check process.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49241	15041-20001-16645	9012 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.23397	-118.55337	Plan check is for power only. Newly connected load exceeds 400-amps (there is 440-amps of newly connected load). Permit is to be pulled under this supplemental application. Title 24 portion of tenant improvement has been approved under master application (15041-20000-16645).*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,883 sq. ft.Note: Power portion of tenant improvement will be plan-checked and permitted under application number 15041-20001-16645.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49242	18041-10000-31760	10250 W SANTA MONICA BLVD 2385	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR POWER AND ENERGY FOR TENANT CORE AND SHELL- Interior alteration to existing space in preparation for future tenant T.I. including wall finish, ceiling grid - TOTAL 480 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49243	18041-20000-15513	8213 N ST CLAIR AVE	91605	2	192B165   669	2309011006	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Issued	04/26/2018 12:00:00 AM	ADDRESS	34.22014	-118.39999	PV1.  Install 4.87 kW DC roof mount grid tied PV system.  (15) modules with microinverters and PV monitoring circuit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49244	10041-20000-07638	614 W 35TH PL 1st FL	90089	8	118-5A201   5	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/26/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	ADDRESS	34.01998	-118.28258	Plan check T-24 Energy (general/emergency lighting) for TI of mechanical room (1st floor) at USC Marianne & J. Douglas Pardee Tower.  Permit for replacing MCC board, new ckts, new equipment and misc permit for refeeding existing equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49245	17041-10005-00340	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.16326	-118.37388	"DELTA ""A"" CHANGES TO APPROVED PLANS FOR ADDING 5 @ ""AIR PUMPS"" RATED 120V, 130W IN UNITS 315, 415, 515, 615 & 715<<<<Full PC for power and energy. New mixed use housing complex -297 dwelling-unit 6 levels of apartment on top of on grade market (core and shell)  above 2 -level of type I construction parking garage.  Scope includes three new services/distribution boards(2500A & 1600A), new panels, new circuits, and new lights for two structures. Total affected area is 266331 Sq. Ft.  B#16010-10000-04268@@@@BUILDING COVERS TWO ADDRESSES:  5101 LANKERSHIM BLVD AND 5130 KLUMP AVE.@@@>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49246	18041-10000-08526	9217 S AIRPORT BLVD AViS	90045	11	093B169    89	4124009920	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	33.95197	-118.38615	SERVICE AND POWER AND LIGHTING FOR NEW AVIS PARKING LOT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49247	18041-20000-15714	12759 W VAN NUYS BLVD	91331	7	210B161    41	2533019032	[Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.27548	-118.41208	TI for OSHPD-3 primary care clinic.  Plan check for power and energy.  6300 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49248	19041-10000-29861	6020 N ELMER AVE	91606	2	177B173  1050	2337007008	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.18014	-118.37683	PV1 roof mounted, Scope of work includes 16 modules(Q-peak 305) ,optimizers (SE P320), with a central inverter (SE3800H-US). System size is 3.8KWac/4.880KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49249	17041-10000-22206	18337 W VENTURA BLVD	91356	3	171B125    86	2160009030	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.1673	-118.53189	Plan check for power and Title 24.  Interior T.I. of existing Bank of America with rooftop AC replacement.  New connected load > 400 amps.  Lighting area = 9,763 sq. ft.       Building permit #17016-10000-16548	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49250	17041-10000-00185	2939 W LEEWARD AVE 1-80	90005	1	132B197   275	5077016030	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			01/04/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.05886	-118.28782	INSTALLATION OF NEW FIRE ALARM SYSTEM IN A 5-STORY APARTMENT BUILDING. 441 FA DEVICES AND 15 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49251	16041-10000-09725	22965 W OXNARD ST	91367	3	177B097   456	2039016016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.17929	-118.62756	PV1, INSTALL 10 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(38) MODULES: CANADIAN SOLAR CS6P-265P(1) INVERTER: SOLAREDGE 10000A-USSE-P300 is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49252	18041-10000-26003	3261 S OVERLAND AVE	90034	5	120B161   241	4254012053	R1-1, R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.02779	-118.41424	FIRE ALARM SYSTEM UPGRADE WITH 266 DEVICES IN AN EXISTING SCHOOL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49253	17041-20000-26340	6300 W SANTA MONICA BLVD	90038	13	144B185   768	5533017019	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.09052	-118.32692	Plan check for energy only. TI to restaurant (changing Yoshinoya to Jack in the Box). New lighting (incl. emergency): indoor-1,846sqft; outdoor-29,555sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49254	18041-10000-22582	6064 W OLYMPIC BLVD	90036	10	132B177   667	5086001066	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	08/11/2018 12:00:00 AM	ADDRESS	34.05791	-118.3635	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR T-MOBILE RETAIL. 2014 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49255	19041-30000-16994	1900 S AVENUE OF THE STARS Suite 1200	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for Title 24 only. Project site is an existing tenant space on the 12th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 3,754 sq. ft.Note: Building application has been generated under 19016-40000-12982	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49256	17041-10001-45140	4553 S GLENCOE AVE 155	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	33.98415	-118.43328	PC for T24 only for new lighting and receptacles for office TI. Master permit is under 17041-90000-45140. B# 17016-10000-31068.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49257	16041-20001-33295	7301 N QUARTZ AVE	91306	3	186B117   864	2115010018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.20309	-118.56466	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of pv system, roof-mounted solar on SFD. Interconnect with 200A MSP. Derating main to 175A. There is an exisitng 5kW pv system on SFD. New system is 3kW, ungrounded; (10) 315W pv modules; each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49258	14041-20000-03535	12459 W BRADDOCK DR	90066	11	108B157  1601	4221005055	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	33.98852	-118.42056	PV1 SINGEL FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49259	19041-10000-02288	961 S ELDEN AVE 1-45	90006	1	129B197    32	5076003031	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.05373	-118.28798	PLAN CHECK FOR ROOF MOUNTED 27.6KVA PV2 SYSTEM CONSISTING OF 3 CENTRAL INVERTERS ((2)SE10000H-US&(1)SE7600H-US) WITH 75 MODULES USING P400 OPTIMIZERSPERMIT FEE IS $ 0 IN ACCORDANCE WITH AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49260	12041-20000-01953	9301 N TAMPA AVE #189	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Info Complete	01/26/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I. to existing space inside the Northridge Mall.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49261	12041-20000-18386	6600 N TOPANGA CANYON BLVD #1082C	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM			PC Info Complete	09/19/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to existing retail space 1082C.  Install general/emergency lighting with Tailor Method.  Plan check for lighting only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49262	17041-20000-30961	19538 W LEMARSH ST	91324	12	204B117   338	2726015009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Issued	08/30/2017 12:00:00 AM	ADDRESS	34.25533	-118.55921	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49263	16041-10000-00576	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	Full plan check for a T.I located in the 2nd and 3rd floor (TSA inspection room) of Tom Bradly LAX airport.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49264	19041-20000-38168	9271 N CANTERBURY AVE	91331	6	198B153   684	2642024001	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.23869	-118.43436	PV1.  Install 7.92 kW DC roof mounted grid tied PV system.  (24) modules with (12) microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49265	16041-20000-45332	1203 S 5TH AVE	90019	10	129B189   652	5081009020	RD1.5-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.04968	-118.32157	Plan check for installation of solar pv arrays on SFD and detached guest house. SFD has a central string inverter, and the guest house has microinverters. Interconnect with a 200A MSP.3.8kW string inverter + 2.64kW microinverter system = total ungrounded system size of 6.44kW.(25) 300W pv modules, each with a 300W power optimizer. (11) 300W pv modules, each with an EnPhase M250 microinverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49266	15041-20000-05028	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.30237	-118.46212	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LGHTING.  TOTAL SQUARE FOOTAGE 2382	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49267	15041-10000-08729	800 S FIGUEROA ST SUITE 1020	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.04771	-118.26116	TI TO AN EXISTING HIGH RISE.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN SUITE 1020.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49268	18041-20000-16854	19950 W RINALDI ST #103	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Issued	09/11/2018 12:00:00 AM	ADDRESS	34.27535	-118.56939	Partial tenant improvement of (E) medical office space.   Plan check for power and energy.Building permit filed under 18016-20000-13347.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49269	19041-30000-05475	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Info Complete	04/08/2019 12:00:00 AM	ADDRESS	34.04994	-118.41129	Installation of optional standby generator and associated distribution equipment for digital vault upgrade.Note: Building applications have been generated under 19016-30000-04341/19020-30000-00400	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49270	17041-20000-18367	15260 W VENTURA BLVD #725	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH-RISE. SUITE 725	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49271	17041-10002-02345	6656 W HOLLYWOOD BLVD	90028	13	148-5A185 137	5547014010	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Issued	10/18/2017 12:00:00 AM	ADDRESS	34.10134	-118.33536	PC FOR CHANGES TO APPROVED SET UNDER DELTA 4. SCOPE INCLUDES CHANGES TO LIGHTING FIXTURES REVISIONS TO T-24 AND REVISIONS TO PANELS SCHEDULES. ADDING ADDITIONAL MOTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49272	18041-20003-20772	14235 W OXNARD ST	91401	6	177B153   828	2240025028	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.17954	-118.44357	03-12-2019 Changes to an approved set of plans, changes include update lighting fixture manufacture, Changes has been clouded. Plan check only. Permit covered under master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49273	17041-10001-20930	23872 W FRIAR ST	91367	3	177B089    35	2033018001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.18522	-118.64627	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49274	11041-20000-01459	10823 N ZELZAH AVE Bld. B, C1-,C2, D	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM			PC Info Complete	01/25/2011 12:00:00 AM	ADDRESS	34.2668	-118.52366	Install outdoor lighting.  Plan check for energy only.NOTE:  Permit is under 11041-20000-01457	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49275	14041-10000-18673	7419 N BELLAIRE AVE	91605	2	186B161   476	2305026036	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.20638	-118.40974	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT TO (E) INDUSTRIAL BUILDING; NEW FOOD PROCESSING FACILITY FOR BAKED GOODS  (4458 SQ FT) , EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49276	17041-20000-22771	19330 W WINGED FOOT CIR	91326	12	216B117   226	2822009016	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.28676	-118.55455	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (25) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49277	14041-20000-15307	432 S CITRUS AVE	90036	4	135B185   320	5507013018	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.06585	-118.33954	4.5KW roof-mounted PV1 system with (1)  Power one PVI-3.8-TL  inverter and (18) Canadian Solar CS6P-255M module.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49278	10041-10000-12055	2400 W OLYMPIC BLVD	90006	1	130-5A201 143	5136003018	C2-1	Central	Westlake	Pico Union		2095.10, 2098.10	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	09/27/2010 12:00:00 AM		Permit Finaled	03/18/2011 12:00:00 AM	ADDRESS	34.05222	-118.28386	PROPOSED TENANT IMPROVEMENT W/IN (E) AUTO REPAIR GARAGE INCLUDES NEW DISABLED UNISEX RESTROOM.  ADD 420 SQFT. STORAGE AREA.  plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49279	19041-10001-13794	110 S BARRINGTON AVE	90049	11	135B145   573	4401006020	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Issued	11/19/2019 12:00:00 AM	ADDRESS	34.06502	-118.46967	Changes to an approved set of plans. All changes are clouded. Changes include revising lighting floor plans, revising Title 24 calculations, and revising emergency photometrics. Changes to reflect as built.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49280	19041-20000-16938	13211 W VICTORY BLVD	91401	2	180B157  1175	2326025033	(T)(Q)RAS3-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Re-Activate Permit	08/20/2019 12:00:00 AM	ADDRESS	34.18684	-118.42076	new 600 amp service for sfd.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49281	19041-10000-35929	1506 W 84TH ST	90047	8	097-5A195  64	6034022011	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	33.96261	-118.30285	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.16KWdc / 5.0KWac. (16)MODULES-CANADIAN SOLAR 260W(16)OPTIMIZERS-SOLAREDGE P300(1)INVERTER- SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49282	13041-20000-09487	11831 W VOSE ST	91605	2	183B169   185	2321004004	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.19855	-118.39129	Changes to previously approved set of plans. 3000A 480 3-phase service changed to a 800A 3-phase delta service. Changes to voltage drops and fault current, all equipment inside building is the same as previously approved.NEW WAREHOUSE / OFFICE BLDG -	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49283	14041-10001-08724	1916 E 1ST ST	90033	14	129A221   284	5174016027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			Verifications in Progress	06/03/2014 12:00:00 AM	ADDRESS	34.04613	-118.21695	(((EXPEDITE FEES)))PV2 ROOF MOUNTED 3PHASE SYSTEM. TOTAL SYSTEM SIZE 10KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49284	19041-10000-42812	6310 W 3RD ST 1ST FLR	90036	4	138B177   796	5509018009	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.07108	-118.35975	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW CIRCUITS, NEW LIGHTS. NEW CONNECTED LOAD > 400A. TOTAL AFFECTED AREAS IS 4694 SQ. FT. (TI FOR E) RETAIL TYPE I-B COMMERCIAL BUILDING.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49285	18041-10000-32034	21240 W BURBANK BLVD BLDG #30	91367	3	174B105    40	2149016026	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.17307	-118.59314	PLAN CHECK FOR TITLE 24 ONLY - T.I. RENOVATION OF OFFICE SPACE, REMOVE AND CONSTRUCT NON-STRUCTURAL PARTITION WALLS AND CEILING. NO CHANGE IN USE. - 1264 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49286	19041-10000-08967	1106 N LINDA FLORA DR	90049	5	144B145   165	4369001013	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	05/25/2019 12:00:00 AM	ADDRESS	34.09002	-118.46472	"[E-plan]PC FOR 1 TESLA POWERWALL BATTERY BACKUP SYSTEM. PV permit pulled under Permit# 18041-90000-35385.INSPECTOR TO VERIFY BACK UP LOADS. ""COMPLY WITH DEPARTMENT ORDER effective date02/12/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49287	12041-20000-24806	400 S HOPE ST Lobby 1	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM			PC Approved	10/17/2012 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for Title 24 and emergency. Chase Bank. 6040 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49288	16041-10000-23662	57 E MARKET ST	90291	11	108A143   429	4226007009	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Issued	07/06/2016 12:00:00 AM	ADDRESS	33.98811	-118.47335	Installation of a roof mounted solar system to a commercial site. Installing a cetral inverter rated at 7.6 kW (SOLIVIA 7.6 TL) and 30 solar modules (Q.PEAK-G3 265-280).	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49289	15041-20000-17388	385 E SWINFORD ST	90731	15	021B201   194	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	33.7494	-118.27878	Plan check for a power only. Project site is a new commercial building. Project scope is the installation of a new 600-amp service and 600 amp distribution equipment only. No loads or tenant breakers are being installed. Project site is within a methane buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49290	15041-10000-33439	5141 RODEO ROAD	90018	10	120B177  1104	5047007010		South Los Angeles				2201.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	PIN	34.02183909	-118.35727162	PV1, INSTALL NEW 2.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49291	16041-20000-40967	5670 W WILSHIRE BLVD 10th Fl RR-Lobby-Corr	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/26/2016 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for energy only. TI to 10th floor corridor, lobby, and restrooms. New lighting (incl. emergency). 1,540sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49292	17041-20000-20978	10861 W WEYBURN AVE	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM			PC Approved	09/01/2017 12:00:00 AM	ADDRESS	34.06247	-118.44344	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 89,961 sq. ft.Note: Building application has been generated under 17016-20000-16817	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49293	17041-20000-23671	20016 W BLYTHE ST	91306	3	189B113   328	2106002***	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Expired	04/21/2024 12:00:00 AM	ADDRESS	34.21466	-118.56922	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49294	15041-20000-16553	565 N KENTER AVE	90049	11	135B137   132	4426037002	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.06899	-118.48766	Plan check for PV roof mounted system. System size 11.4kW with 35 modules and 1 inverter (11.5kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49295	14041-10001-11208	3037 N ARROWHEAD DR	90068	4	156B185    85	5577035011	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	07/15/2014 12:00:00 AM	ADDRESS	34.12419	-118.32767	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{[PV1, INSTALL 9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL WITH OPTIMIZER.(2) TRANSFORMERLESS INVERTER(S): SOLAREDGE SE6000A-US-ZB-U AND SE3000A-US-ZB-U(36) TRINA SOLAR # TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49296	14041-10001-04643	608 W OLIVER ST	90731	15	018B197   316	7448010038	R2-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM			PC Approved	09/03/2014 12:00:00 AM	ADDRESS	33.74704	-118.29034	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STANDARD PLAN. 3 KW DC.(13) TRINA TSM-235(13) ENPHASE M215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49297	16041-20000-10905	6116 N ST CLAIR AVE	91606	2	177B165   455	2333006036	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	34.18173	-118.39967	PV1.  Install 4.16 kW roof-mounted PV system.  (13) AC modules using microinverter/ACM standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49298	12041-10000-16212	6338 W 78TH ST	90045	11	099B165   139	4109004015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	33.97071	-118.39786	New rooftop 7.92kw photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49299	16041-20001-31925	7235 N NESTLE AVE	91335	3	186B125   953	2119026001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.20239	-118.53073	Changes to scope of online permit - reduction of number of modules from (22) to (17).  Reduction in inverter rating from 6 kW to 5 kW.  Plan check only for changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49300	14041-20001-01483	14714 W ORACLE PL	90272	11	132B129    53	4422032008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.05537	-118.51911	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.8KW AC USING 2 TRANSFORMERLESS INVERTTERS NONSTANDARD PLAN. TOTAL OF 40 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49301	13041-10000-05011	20600 W VENTURA BLVD NORTH	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			02/27/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR APARTMENT COMPLEX. TOTAL OF 2 PANELS AND 539 DEVICES. THIS APPLICATION IS FOR THE NORTH BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49302	13041-10000-29466	2259 N LINDA FLORA DR	90077	5	153B145   122	4377010003	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.11461	-118.46416	PV1, Installing roof-mounted solar array, interconnect with main panel. System size: 12.0 KW DC.48 panel and 720 sq ft.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49303	18041-10000-28555	510 E 2ND ST	90012	14	129A215   216	5163009901	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM			Corrections Issued	07/30/2018 12:00:00 AM	ADDRESS	34.047	-118.23761	PC FOR TITLE 24 ENERGY ONLY FOR CONVERSION OF  LABORATORY INTO OFFICE SPACE AND RESTROOM  WITH NEW LIGHTINGTOTAL AFFECTED AREA 2054 SQ.FT SCOPE INCLUDES NEW CIRCUITS AND LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49304	12041-10000-02176	560 S ST LOUIS ST	90033	14	126A221   109	5183019032	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Public Safety Only			01/30/2012 12:00:00 AM	01/30/2012 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.03916	-118.21715	New Fire Alarm system. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49305	14041-20000-17205	5522 W BARTON AVE	90038	13	144B193  1250	5535008008	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.08743	-118.31214	PV1.  install 5.2 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49306	14041-10001-25711	4039 N CODY ROAD	91403	4	165A147   279	2277013025	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	34.14436	-118.4639	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 14.03 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(55) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49307	17041-10005-37680	5455 W 111TH ST	90045	11	087B173    10	4129036910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	33.93635	-118.37364	Change to approved set by updating equipment and adding circuits. all changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49308	18041-10000-28580	6333 W 3RD ST STE  E16	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES INTERIOR T.I. OF EXISTING 2-STORY RETAIL BLDG, NEW PANEL, CIRCUITS AND LIGHTING IN CERTAIN LOCATIONS. DESIGN IS USING TAILORED METHOD TOTAL SQ. FT. 14486.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49309	18041-10000-09034	7120 N CORBIN AVE	91335	3	183B117   138	2130001086	RD5-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Issued	03/13/2018 12:00:00 AM	ADDRESS	34.19973	-118.56207	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49310	11041-10000-19108	2033 E 4TH ST	90033	14	127-5A221 201	5183012028	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Apartment			09/08/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Expired	10/02/2013 12:00:00 AM	ADDRESS	34.04247	-118.21558	3 story apartment  bldg, replacing one fire alarm  panel all devices existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49311	16041-10000-08157	2321 S FOX HILLS DR	90064	5	129B161   222	4315016006	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			03/08/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.05024	-118.41482	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 4-STORY,  8-UNIT APARTMENT BUILDING OVER BASEMENT GARAGE; NEW 600A 120/240 3PHASE, 4WIRE SERVICE. TOTAL AFFECTED AREA IS 9275 SQ. FT.  APARTMENT SITE IS ON A METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49312	12041-10000-12513	11146 W PALMS BLVD	90034	11	117B157   181	4252005017	C2-1VL	West Los Angeles	Palms - Del Rey - Mar Vista	Mar Vista		2718.01	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.01922	-118.42195	Change of use from a yougurt shop to a pizza restaurant.  Load is less than 200A and occupancy load is 27, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49313	16041-20000-01530	4558 W BRAZIL ST	90039	13	165B201   218	5593011039	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.14674	-118.2745	"""0$ permit fees due to senate bill 1222""Plan check for Feed In Tariff (FIT) PV roof mounted system on commercial building. System size: 140kWac with 540 modules and 7 inverters(20kW)"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49314	17041-10000-04991	20703 W COLLINS ST	91367	3	174B109   407	2151021027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.17288	-118.58364	PV INSTALL 8400W DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE(30) MODULES: HANWHA Q-CELL QPLUS-BFR-G4.1280(30)OPTIMIZERS-SOLAREDE P300(1) INVERTER: SOLAREDGE SE 7600A-UA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49315	15041-20002-19489	2734 N FLETCHER DR	90039	13	151-5A211  83	5436031015	[Q]C2-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Expired	04/11/2018 12:00:00 AM	ADDRESS	34.11088	-118.25053	03/10/2016 Plan check for a lost set of plans. Project scope has remained the same. Total lighting area = 3,125 sq. ft. Permit to be pulled under this application.*****Previous Work Description*****Title 24 plan check only.  Total area = 3,125 sq. ft.  T.I. to existing commercial space.  Change of use from retail to office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49316	16041-10000-45541	21141 W VENTURA BLVD	91364	3	171B105    79	2167001009	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.16731	-118.59372	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49317	19041-20000-22166	10960 W WILSHIRE BLVD Ste 980	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.058	-118.44597	Existing commercial office remodel.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49318	18041-20000-45272	7540-7546 N SEPULVEDA BLVD	91405	6	186B145   247	2221001025	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Issued	12/21/2018 12:00:00 AM	ADDRESS	34.20774	-118.46601	Plan check for Title 24 Energy only convert coin laundry to bakery/restaurant expandsion of existing Bakery/Restaurant/Market. Total area: 1822 sq ft. B#18016-20000-17937	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49319	17041-30001-12552	1777 S WESTWOOD BLVD #200	90024	5	129B153   439	4324028045	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.05045	-118.43782	Plan check for Title 24 only in existing space T.I. total area: 1,328 sq ft Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49320	16041-20000-13222	3531 E 3RD ST	90063	14	124-5A229 192	5179014021	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.03368	-118.19333	Plan check for a PV1 roof-mounted PV system. System size is 1.7 kWac and consists of (8) modules and (8) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49321	12041-20002-30756	12001 W VICTORY BLVD	91606	2	180B165   700	2322007056	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.18684	-118.39464	Plan check for power and energy.  Bakery and kitchen. Less than 100 occupants. Electrical work was within the scope of work for the Civil Engineer. 8419sqft. (((PC FOR NEW LIGHTING ONLY. CHANGE IN LIGHTING FROM ORIGINAL APPLICATION. PC IS T24 ENERGY ONLY. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49322	19041-10000-09666	10406 W MAGNOLIA BLVD	91601	4	171B177   655	2419024024	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Issued	03/19/2019 12:00:00 AM	ADDRESS	34.16477	-118.35749	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR ONLY) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49323	15041-10000-27688	11811 W CULVER BLVD	90066	11	111B161   959	4233022010	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Public Safety Only			08/24/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	33.99735	-118.41647	NEW FIRE WARNING SYSTEM FOR 5-STORIES 28 UNITS APT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49324	13041-20000-23806	10538 N PINYON AVE	91042	7	207B201   296	2566001060	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.2607	-118.28481	PV1 TRANSFORMERLESS SYSTEM. 6 MODULES AND 1 INVERTER. 1.47KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49325	11041-10000-03982	1248 S FIGUEROA ST #101	90015	9	126A205    19	5138025014	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	01/27/2012 12:00:00 AM	ADDRESS	34.04096	-118.2674	"TI  RESTAURANT,  4499 SF  CONSTRUCT  15'0"" X 9' 0""  ( 139 SQ FT )   MEZZANINE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49326	18041-10000-00132	3208 N HUMBOLDT ST	90031	1	141A221    16	5205006059	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.08254	-118.21583	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49327	16041-30001-15026	3242 E 6TH ST	90023	14	123A227   201	5186015023	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2016 12:00:00 AM			Reviewed by Supervisor	05/10/2016 12:00:00 AM	ADDRESS	34.03166	-118.20093	Expedite per applicant request((((((Plan check for PV roof mounted system. System size: 2.3kW ac with 9 panels and 9 microinverters. Submit per applicant.))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49328	15041-20000-24721	9459 N RUFFNER AVE	91343	12	198B137    64	2687014026	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.24268	-118.4973	Plan check for PV roof mounted system. System size: 6.0kW with 29 modules with 1 inverter(6.0kW) Stand plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49329	14041-20000-22473	16458 W BRYANT ST	91343	12	195B137   911	2689028021	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Expired	09/19/2016 12:00:00 AM	ADDRESS	34.2274	-118.49136	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.6kW(2) SolarEdge SE3800A-US-ZB-U transformerless inverter(34) Kyocera #KD255GX-LFB3 pv modules(34) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49330	18041-20000-19630	15167 W NORDHOFF ST	91343	7	198B145   370	2656022001	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM	ADDRESS	34.23565	-118.46299	Plan check power only 800A  Service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49331	16041-20000-20847	6032 W ROMAINE ST 1-6	90038	13	144B189   866	5534025007	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Apartment			06/14/2016 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.08872	-118.32337	NEW APARTMENT BUILDING 3 STORY.  600 AMP SERVICE. FULL PLAN CHECK.BUILDING APPLICATION NUMBER UNDER 15041-20000-02410	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49332	11041-20000-22398	20905 W SHERMAN WAY	91303	3	183B109    58	2112017001	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	34.20126	-118.58878	PLAN CHECK POWER AND ENERGY FOR  MEDICAL OFFICE TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49333	17041-10000-06589	686 E 42ND PL	90011	9	114A207   230	5115007011	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	04/01/2017 12:00:00 AM	ADDRESS	34.00649	-118.26364	PV1 INSTALLATION OF A NEW 6.52 KWdc/7.60KWac ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(34) MODULES: HANWHA Q-CELLS # Q PLUS-G4.1/SC-280(1) INVETER: DELTA # SOLIVIA 7.6 TL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49334	15041-20001-31800	7002 N OWENSMOUTH AVE	91303	3	183B105   664	2138008012	P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM			PC Approved	10/07/2015 12:00:00 AM	ADDRESS	34.19758	-118.60139	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 13.5 kWac and consists of (54) modules, (54) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49335	12041-20000-26891	4604 N CEDROS AVE	91403	2	168A149   114	2265003002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.15494	-118.45291	New rooftop photovoltaic system for an existing single family residence.  System uses Enphase microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49336	17041-20001-37035	627 N DILLON ST	90026	13	141A203   351	5401014015	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Apartment			08/23/2018 12:00:00 AM			PC Approved	09/19/2018 12:00:00 AM	ADDRESS	34.07914	-118.27881	8/21/2018changes to an approved set of plans.  changes noted delta 1.  changes to include new unit panels, feeders, and unit load calculations.  em lighting with battery back up and recircuiting of panel schedules.this is plan check only.    ((((Plan check for power and energy. Project site is a new 4-story, 30-unit apartment building over 1-story of basement parking garage. Work includes a new 1,600-amp service and a total lighting area of 31,570 sq. ft.Note: Building application has been generated under 17010-20000-02602))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49337	16041-10000-30048	3000 S ROBERTSON BLVD 2nd Floor	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	PC for TI-24 for office space only within medical administration building.Installing new 100 A panel, new LED lights and new receptacles.**TENANT IMPROVEMENT FOR (E) OFFICE. ADD NON BEARING PARTITIONS AND WORK STATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49338	18041-20000-02049	7201 W FLORAMORGAN TR	91042	7	201A199   259	2564029017	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Issued	02/07/2018 12:00:00 AM	ADDRESS	34.24464	-118.28893	Plan check for the addition of a Tesla PowerWall to an existing PV1 roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49339	13041-10003-34677	1200 S GRAND AVE	90015	14	126A207   138	5139023907	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			06/09/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.03989	-118.26331	6/9/16: Changes to approved set under Delta 48. Changes include: change circuit breakes, change lighting circuits, add exterior sign, add elevator smoke guard door power, RTU for methane blower, update photometrics.  01/19/16Changes to an approve set. All changes are made under delta 28.1. Changes include changing type A units to 100A breakers, updated voltage drop calculations, adding emergency photometrics, and updating title 24 forms.Note: permit pulled under PCIS#13041-10000-34677 permit pulled under pcis#13041-10000-34677((((((FULL PLAN CHECK FOR  New 7 Story (5 Story over 2 Story Podium) Mixed Use Building w/ 287 Unit Apartment & Retail Building over two level parking basement. PROJECTED AREA FOR LIGHTING WORK IS APPOXIMATELY 344,451 SQ FT AREA. SERVICEbuilding permit under: 13010-10001-02721, DESCRIPTION LISTED AS 347 UNITS; ELECTRICAL PLANS WERE BASED ON CALCULATIONS FOR 300 UNITS (REFER TO SHEET 1E0.03 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49340	13041-10000-34633	1888 S SEPULVEDA BLVD	90025	5	126B153   131	4323021013	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.04476	-118.44163	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 260 SQ FT. REPLACING TOTAL OF 1 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49341	19041-20000-36521	6908 N BERQUIST AVE	91307	12	183B093   577	2026021002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.1949	-118.63438	PLAN CHECK FOR NEW PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.34KW DC/10.4KW AC. SCOPE OF WORK CONSISTS OF (36) PV MODULES, (2) 5.2 KW INVERTER, AND A 125A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49342	17041-20000-12185	1742 N REEDVALE LANE	90049	11	135B137   406	4426016010	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM			Reviewed by Supervisor	04/26/2017 12:00:00 AM	ADDRESS	34.06537	-118.49241	NEW TWO STORY SINGLE FAMILING DWELLING WITH AN  ATTACHED GARAGE.  600A 240V 1PH-3W SERVICE.  PLAN CHECK FOR POWER.  PERMIT ISSUED UNDER 15010-10000-02527	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49343	18041-10000-36446	10701 W VANOWEN ST	91605	2	183B177    62	2466017023	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.19414	-118.36424	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49344	18041-20000-08676	7600 N BALBOA BLVD 101-206	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Closed	05/22/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO MASSAGE PARLOR. 878 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49345	14041-10000-07134	5555 W HOLLYWOOD BLVD	90028	13	148-5A193 134	5544003049	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.1019	-118.31132	950 SQ.FT. OF CORE TENANT IMPROVEMENT.  INCLUDING THE ADDITION OF AN OFFICE & BATHROOM.  (N) DEMISING WALL.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49346	13041-10000-17081	8500 W BEVERLY BLVD #649	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	APPLICATION FOR PLAN CHECK AND PERMIT. TI beverly center retail to retail hirise. load less than 400A per applicant. space #649 brookstone	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49347	19041-10000-02166	7518 S VERMONT AVE	90044	8	099B197    74	6020008004	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.97111	-118.29131	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49348	16041-10000-39461	444 S SAN VICENTE BLVD RM 601.7	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM			PC Info Complete	12/08/2016 12:00:00 AM	ADDRESS	34.07021	-118.37547	FULL PC FOR POWER AND ENERGY. TI  AT THE IMAGINGB ROOM # 601.7D  & CONTROL ROOM # 601.7B  ON THE 6TH  FLOOR OF ( E ) MEDICAL OFFICE  BUILDING : NEW X-RAY EQUIPMENT & GENERATOR. TOTAL AFFECTED AREA IS 199 SQ. FT.  B#16016-10000-26778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49349	12041-10000-05388	6114 W SUNSET BLVD T-mobile	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Info Complete	03/08/2012 12:00:00 AM	ADDRESS	34.09785	-118.32294	TI IN AN EXISTING T-MOBILE STORE.   PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49350	19041-10001-29457	1143 N ILIFF ST	90272	11	129B129   282	4423006017	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.05065	-118.51989	NEW ROOF MOUNTED 9.9 KW  PV SYSTEM WITH 30 PV MODULES, 30 ENPHASE MICROINVERTERS  AND A TESLA POWER WALL ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49351	12041-10000-02650	2301 E 7TH ST	90023	14	124-5A219 190	5171019007	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	07/02/2012 12:00:00 AM	ADDRESS	34.03467	-118.22307	TI in a bakery. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49352	15041-20001-18803	19950 W COLLIER ST	91364	3	171B113   574	2164005015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.16577	-118.56754	Expedite per applicant request[[[[[Plan check for PV roof mounted systm. System size: 6.0kW with 24 modules and 1 inveter(6.0kW) connected to 400A service panel.]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49353	14041-10000-35150	605 W BOCCACCIO AVE # A	90291	11	108B149  1432	4237006053	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	PIN	33.98921587	-118.45798338	PV1, INSTALL 4.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: YINGLY YL255P-29b(1) INVERTER: ABB PV1-3.6-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49354	16041-10000-32880	9857 N BALBOA BLVD	91325	12	201B133   161	2692012032	C2-1VL	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.24975	-118.5026	PC for T.I.   Title 24 energy only for a single story McDonaldsScope of work includes new lighting. Total area is 1388 sq.ft. (indoor only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49355	15041-10000-26356	3434 S HOPE ST	90007	9	118-5A203  74	5122021010	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Issued	11/13/2015 12:00:00 AM	ADDRESS	34.01983	-118.27801	PLAN CHECK FOR POWER AND ENERGY FOR TMOBILE SITE. INSTALLING NEW EQUIPMENT AND NEW DISTRIBUTION RATED >600AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49356	16041-10000-23818	206 W 6TH ST Basement	90014	14	129A211   220	5144002017	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.04603	-118.25128	PC FOR POWER AND ENERGY. CONVERT (E)  5469 SF  BASEMENT TO NEW BAR / ENTERTAINMENT AREA. OCCUPANCY LOAD > 100. 400A EXISTING SWITCH GEAR. TOTAL AREA OF LIGHTING 5370 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49357	17041-10000-27700	6922 N ALDEA AVE	91406	6	183B133   690	2230002004	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.1963	-118.50824	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 10KVA CONSISTING OF 38 MODULES(SOLARWORLD SW- 290 MONO) AND 1 INVERTER(SOLAR EDGE SE10000A-US) WITH 38 POWER OPTIMIZERS(P320)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49358	16041-10001-25130	15579 W MEADOWGATE ROAD	91436	5	165B141   244	2285003046	R1-1	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	34.14953	-118.47409	08/01/16Changes to an approved set of plans. Changes includes relocating the solar modules on the roof-layout.Note: permit is paid under PCIS#16041-10000-25130((((PV1, rooftop solar installation on SFD, 12.75 kW AC.(51) LG 320 N1C(51) Enphase M250(1) Load center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49359	17041-10000-45645	925 W WEST 34TH ST 4TH FL	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.0239	-118.28647	PC for T24 only for new lighting. Installing new lights, receptacles and equipment. New installed load under 400A. B# 17016-10000-37740. Total area is 1395sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49360	14041-10002-05603	5157 S CRENSHAW BLVD	90043	8	108B185   116	5013018006	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	33.99449	-118.33114	10/19/15CHANGES TO AN APPROVED SET, NOTE CHANGES ON DELTA 13. CHANGES INCLUDE THE ADDITION OF CIRCUITS AND WIRE GUARD PROTECTOR. (((Revisions to approved set.  Delta revisions 3, 6, and 9.  Change of feeders from copper to aluminum for value engineering, extra classroom (architectural revisions), lighting control changes throughout, and updates to elevator motor specifications.  )))(((PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY CHARTERED SCHOOL. 2 SERVICES.FIRE ALARM PLANS TO BE SUBMITTED SEPERATELY. (variance was filed)BUILDING P# 14010-10000-00540 : NEW 3 STORY SCHOOL (74' WIDE X 340' LONG) CONSTRUCTION TYPE II-B  FULLY SPRINKLERED, TOTAL SQUARE FOOTAGE 54,567 SF)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49361	19041-10000-28248	200 N SPRING ST	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.05405	-118.24317	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING BUILDING LA CITY HALL. SCOPE OF WORK INCLUDES 97,300 SQFT OUTDOOR/FACADE LIGHTING FOR PHASE 2 ONLY. ALL USING EXISTING CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49362	17041-20002-41503	1812 S ROXBURY DR	90035	5	129B165   711	4307013027	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.04821	-118.40115	Changes to approved set of plans.  Change of interconnection point to (E) 200 A subpanel within laundry room.  Plan check fee $0.00 by state senate bill no. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49363	18041-20000-24095	333 S HOPE ST 38th-39th Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 only. Project site are the 38th and 39th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 31,406 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49364	16041-20000-09181	15901 W BLACKHAWK ST	91344	12	204B141   211	2668016015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.25837	-118.47866	Install a roof-mounted solar array on a SFD. Interconnect with a 125A MSP.System size: 4.2kW. Ungrounded system. (18) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49365	19041-20000-24258	20700 W SESNON BLVD #174-pv1	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	pv1install roof mounted pv system sized 5.25KW AC interconnetced with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49366	13041-10000-30070	14615 OXNARD STREET	91411	6	177A151    96	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	PIN	34.17979092	-118.45215041	PLAN CHECK FOR POWER AND ENERGY FOR A 30 FOOT TALL HOSE TOWER ON A FIRE STATION.  FIRE STATION PLAN CHECK UNDER 13041-10000-23043. EXPEDITED  THROUGH CITY BOND PROGRAM. TO BE AHEAD OF ALL NORMAL PLAN CHECKS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49367	11041-10001-25029	2959 N GLENDALE BLVD	90039	13	153A207    93	5435028031	[Q]C1.5-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.1147	-118.26485	Modification to previously approved set of drawings to remove one inverter and string and replace one 5kw inverter with an 8kw inverter.          <<<<<PLAN CHECK 30KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49368	18041-10001-27846	7400 N COLDWATER CANYON AVE	91605	2	186B161   521	2324001011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			Reviewed by Supervisor	08/06/2018 12:00:00 AM	ADDRESS	34.20498	-118.41362	**Expedited per applicantInstall Rofftop solar system in a Commercial Building, Build.-A. System size, 20.060 kWptc/ 19.759 kW CEC/ 20kW AC. (68) modules, (68) optomizers, (2) central string inverter, (1) 600A panelboard/load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49369	12041-10000-17650	5620 S MESMER AVE	90230	11	105B165   299	4220015031	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	33.98511	-118.39992	New panel and circuits for an existing Medical Building.  Building is Not State Licensed, NOT CHECKED FOR OSHPD.   No change to lighting.  Plan check for Power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49370	19041-10002-19612	2500 W 7TH ST	90057	1	133-5A201 278	5141014001	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.0583	-118.28122	Change to an approved set by modifying the single line diagram, adding new panels,  and evenly distribute all panel load to balance the system. ckts being remaned and all changes under delta-6 only. ((Full pc (pwr and energy) for commercial tenant spaces 2 story building. Existing service 800A, 120/240V, 1ph, 3w will existing and new loads. area of scope is 21,000sqft.))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49371	10041-20002-03786	18370 W BURBANK BLVD unit # 707	91356	3	174B125   449	2160011029	[Q]C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	06/03/2010 12:00:00 AM	ADDRESS	34.17159	-118.53338	add unit # 707 to address	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49372	14041-20000-26527	8746 N AQUEDUCT AVE	91343	12	195B141   604	2672010004	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.22972	-118.47405	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(12) SUN POWER 327W MODULES(1) POWER ONE PVI-3.8-OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49373	12041-10000-02073	2230 N BARDALE AVE	90731	15	027B193   102	7442005010	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	03/21/2012 12:00:00 AM	ADDRESS	33.7661	-118.30197	New 4kw rooftop photovoltaic system for an existing single family residence.  System uses 17 Enpahse M215 Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49374	15041-20001-05427	10040 N NITA AVE	91311	12	204B101   494	2745007053	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM			PC Approved	03/09/2015 12:00:00 AM	ADDRESS	34.25294	-118.61357	NOTE: Plan check is being expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.25 kWac. System consists of (45) modules, (45) micro-inverters and (1) 100-amp rated PV distribution panel. The main service panel is being upgraded to a 225-amp rated panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49375	14041-20000-23692	16936 W SUPERIOR ST	91343	12	201B133   392	2686025033	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	34.24727	-118.50143	Modification to approved set under 14041-20000-13668.  Change of MSP bus rating and main OCPD.  Relocation of loads from MSP to (N) subpanel.  (((7.24KW PV1 roof-mounted system wtih (32) Yingli YL250P modules, and (2) Power-One-PVI-4.2 and 3.0-OUTD-S-US transformerless inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49376	15041-20000-24720	3256 N BERRY DR	91604	2	159B169   346	2380016015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.13302	-118.38021	Installation of new roof mounted solar PV array.  Total system size = 8.6 kWac.  Two inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49377	19041-10000-15539	6255 W SUNSET BLVD 21ST FL	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	Energy plan check for an office TI located on the 21th floor of a high rise building. Scope includes replacing lighting and equipment with a total area of 14,503 SQ FT. Permit fee is paid under 19041-30000-07474.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49378	13041-10001-27863	3767 S 2ND AVE	90018	10	117B189   251	5042009029	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.01976	-118.31907	EXPEDITED PER APPLICANTS REQUESTPV1. INSTALL ROOFMOUNTED SOLAR ARRAY. INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 7.5 kW. TRANSFORMERLESS UNGROUNDED  SYSTEM.(30) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PV1-6000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49379	14041-20001-31847	2125 S LOUELLA AVE	90291	11	111B149   790	4242022009	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	33.99945	-118.45088	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER WITH 27 MODULES. NONSTANDARD PLAN. DERATING MAIN BREAKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49380	19041-10000-02096	2165 W JOHN S GIBSON BLVD	90731	15	024B197   394	7440016911	PF-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	PIN	33.75805116	-118.28901935	FULL PLAN CHECK FOR POWER AND ENERGY FOR  NEW NAVIGATION CENTER FOR THE HOMELESS, OFFICE, CASE MANAGEMENT AND STORAGE LOCATED IN METHANE ZONE - TOTAL AFFECTED AREA = 5000 SF. b#19010-10000-00208	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49381	14041-10002-14426	3033 W WILSHIRE BLVD	90010	10	135B197  1253	5077008017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.06198	-118.28733	8/4/2016Changing the size of tranformer from 30 kva to 15 kva, Rearreanging branch circuits, indicating relay number. Note changes under delta 2. (((((   Changes to approved set of plans. Changes in title 24 and single line minor changes. changes clouded on plans. revised emergency required circuits to dedicated panel. NEW 18-STORY MIXED-USE BUILDING (CORE AND SHELL ONLY) CONSISTING OF 190 APARTMENT UNITS (LEVEL 5-17) ON TOP OF ABOVE GRADE PARKING GARAGE (LEVEL 1-4) AND ROOFTOP SWIMMING POOL AND ASSEMBLY AREA ON LEVEL 18. THE GROUND LEVEL INCLUDES RETAILS (___S.F), LEASING OFFICE (___S.F.) AND RESIDENT AMENITIES (___ S.F.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49382	13041-20000-04140	11830 W DAVID LANE	91352	6	195B169   663	2631025026	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.23191	-118.39085	New 5.28kw PV system.  Rooftop mounted, using Enphase Microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49383	10041-10002-09004	601 W 7TH ST	90017	14	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Approved	03/09/2011 12:00:00 AM	ADDRESS	34.0475	-118.25665	Revision to the approved plan. Remove the Frymaster and put the locked off  device on the breaker. EPC is for the change. ((((((((((((((((CHANGE OF USE FROM RETAIL TO RESTAURANT ( CHIPOTLE ))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49384	09041-10001-24270	380 W WORLD WAY NORTH-CONCOURSE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans for the north concourse at TBIT -Revisions are noted in  bulletins (GB1 to GB5). On the plans, each change is clouded and noted to the reference GB.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49385	19041-10001-11033	11053 W VENICE BLVD	90034	5	117B161  1032	4252008034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	PIN	34.01442334	-118.41569711	PLAN CHECK ONLY. CHANGES TO APPROVED SET. RELOCATING AC DISCONNECT AND 125A SERVICE SUB PANEL. ((((PV1 SYSTEM SIZE IS 2.14 KWdc, 1.90 KWac CEC. SEVEN CANDIAN SOLAR MODULES (305 WATTS) WITH SEVEN ENPHASE IQ7 MICROIVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49386	19041-10001-08169	20911 S NORMANDIE AVE	90501	15	054B197   168	7349034031	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	33.83966	-118.2994	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED DELTA B. CHANGES INCLUDE RELOCATING MODULES ON THE ROOF-LAYOUT AND RELOCATING ONE INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49387	19041-10000-14289	100 E SUNSET AVE	90291	11	109-5A143 198	4286015900	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.99395	-118.477	Temp' shelter for homeless people. Full plan check for one(Tensile membrane) structure building and shade structure. Scope includes a new 800A service feeding Tensile membrane structure, shade structure, and multiple state approved modular buildings for homeless. Adding new lighting and equipment with total load is more than 400-Amps. Total area is 35,748-SQ FT. B#19010-10000-01545(Tensile membrane structure)B#19010-10000-01546 (shade structure)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49388	17041-20000-13862	1100 S HOPE ST #C1	90015	14	127-5A207 333	5139005***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.04195	-118.2631	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO EXISTING RETAIL SPACE.  HIGHRISE. UNIT C1. 1,681sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49389	17041-10000-18650	331 N GRENOLA ST	90272	11	126B121   464	4414024020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			Reviewed by Supervisor	06/16/2017 12:00:00 AM	ADDRESS	34.04163	-118.54243	Installation of (1) new 200A load center with (1) 5.8 kVA  Tesla AC Powerwall battery for an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49390	11041-10001-16831	2914 W 8TH ST	90005	1	132B197   497	5077023015	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.05751	-118.28966	NEW 85-UNIT, 5-STORY APARTMENT COMPLEX WITH 2-LEVEL UNDERGROUND PARKING.  PLAN CHECK FOR POWER AND ENERGY.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.(((((((((((((( Changes made to existing  plans , all pages are clouded with all changes ,  ))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49391	11041-10000-18557	8601 S LINCOLN BLVD 1-405	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	33.95939	-118.41943	PLAN CHECK ONLY FOR T-24 FOR NEW OUTDOOR SIGN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49392	17041-10000-45700	20700 W DEARBORN ST	91311	12	198B109   159	2748037025	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.23712	-118.58477	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49393	19041-20000-38470	5400 N BALBOA BLVD 330-331	91316	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.1692	-118.50087	Plan check for power and  Energy for Tenant Improvement existing Medical office. Total area: 556 sq ft. B#19016-10000-28255	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49394	17041-10000-26778	13160 W RIVIERA RANCH ROAD	90049	11	132B137   174	4425025001	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.06037	-118.49606	PC FOR ROOF MOUNTED PV ON SFD (ON STABLE).SYSTEM SIZE 5.0 KW ACSCOPE INCLUDES CENTRAL INVERTER WITH 18 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49395	19041-10000-04422	926 N NORDICA DR	90065	1	153A221   316	5475017025	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.11284	-118.22039	PLAN CHECK FOR ENRGY STORAGE SYSTEM IN A SINGLE FAMILY DWELLING WITH EXISTING PV. SCOPE INCLUDES 2 x 13.5KWH  BATTERIES (TESLA POWERWALL), NEW LOAD CENTER 125A AND NEW DISTRIBUTION BOARD 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49396	13041-20000-16617	18924 W KIRKCOLM LANE	91326	12	219B121   353	2820013016	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.29344	-118.54585	PV1 SINGLE FAMILY DWELLING. USING TRANSFORMERLESS SYSTEM USING POWER OPTIMIZERS. TOTAL SYSTEM SIZE 8.84KW. USING TOTAL OF 34 MODULES. SYSTEM TO BE CHECKED FOR MAIN SERVICE UPGRADE AND PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49397	17041-20000-15070	2949 1/2 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.03799	-118.20329	PV2.  Install roof mounted grid tied PV system sized 1.2 kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49398	10041-10002-20309	5200 W WILSHIRE BLVD	90036		132B181    30	5507024010	[T][Q]C4-2D-CDO		Wilshire	Greater Wilshire			Electrical	Electrical	Apartment			06/26/2012 12:00:00 AM			PC Approved	09/11/2012 12:00:00 AM	ADDRESS	34.06194	-118.3435	PLAN CHK FOR FIELD CHANGESOF APPROVED SET OF PLANS- AS-BUILT SET OF PLANSNEW MIXED USE APT (478 UNITS) 6 stories	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49399	10041-10000-06956	1149 N GOWER ST	90038	13	144B189   386	5534008016	R3-1	Central	Hollywood	Hollywood Studio District		1908.00, 1909.02	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	05/14/2010 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.09219	-118.32242	Small restaurant on the first floor , title 24 , 1st time tenant , 200 amps panel , 1600 amps existing service , 7 days , 23 days will provide with variance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49400	15041-20000-34815	10300 W VENICE BLVD	90232	5	117B165    21	4208005020	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.02072	-118.40287	Plan check for power and lighting. Project site is a new 5-story, 34-unit apartment building. Building has (2) levels of parking (1 below-ground and 1 above ground) and (4) levels of residential units. Service size 2000-amps. Total indoor lighting area = 18,500 sq. ft. and total outdoor lighting area = 1,750 sq. ft. Note: Building permit application has been filed under 14010-10000-03787	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49401	18041-20000-13449	7317 N DELCO AVE	91306	3	186B109   908	2114016017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.20327	-118.57877	PC for 7.6kW(ac)/4.72kW(dc) rooftop solar for SFD with 5kW back-up battey . Installing 16 modules with optimizers, multimode inverer with autotransformer, backup panel and 5kW back up battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49402	16041-10000-45277	11752 W LA MAIDA ST	91607	2	168B169   355	2355017002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Issued	12/30/2016 12:00:00 AM	ADDRESS	34.15848	-118.38944	PC FOR ROOF MOUNTED PV ON SFD. SYS SIZE IS 3.8KW(AC)INCLUDES 1 CENTRAL INVERTER SOLAR EDGE SE3800A-US14 MOUDULES SUNMODULE SW 28514 OPTIMIZERS SOLAR EDGE P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49403	16041-20000-23219	3620 S VERMONT AVE B26, B28	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.02213	-118.29133	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISITNG PANELS.  PLAN CHECK FOR ENERGY AND EMERGENGY LIGHITNG.  TOTAL SQUARE FOOTAGE 612. SCOPE IN ROOM B26	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49404	14041-10001-06217	5250 N HERMOSA AVE	90041	14	163-5A225 142	5669023006	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	34.14269	-118.20757	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49405	14041-10000-17304	10459 W TUXFORD ST	91352	7	198B177   137	2544014003	A1-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.23764	-118.35908	Plan check for new fire alarm system.  Total system size = 25 devices.Install new fire alarm system at nature education facilities admin. building and classroom building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49406	10041-10000-22142	16403 W VENTURA BLVD STE-C	91436	5	168B137   347	2260009043	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.15747	-118.49025	Ti, retail to retail, title 24 and energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49407	14041-10002-12853	3351 S GAFFEY ST	90731	15	006B197     4	7469018904	OS-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	33.71374	-118.29306	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 4 ON PLANS. CHANGES CLOUDED. ADDED A COUPLE OF CIRCUITS AND A PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49408	18041-30001-22848	2818 S LA CIENEGA AVE 2nd & 3rd-floor	90034	10	123B173   926	5065003037	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.03228	-118.37838	PLAN CHECK FOR CHANGES TO APPROVED SET FOR T24.SCOPE INCLUDES CHANGE IN LUMINRES AND REVISION TO T24 FORMS. THIS IS PLAN CHECK ONLY.PERMIT PULLED UNDER MASTER. (B# 18016-30000-17955)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49409	18041-10000-26793	1310 S ABBOT KINNEY BLVD	90291	11	108B145  1283	4238004015	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.99094	-118.46783	FULL PC FOR POWER AND ENERGY. TI FOR A RETAIL STORE. COMBINE 3 RETAIL STORES INTO ONE. SCOPE INCLUDES RELOCATINGS PANELBOARDS, AND ADDING NEW LOADS. TOTAL AFFECTED AREA IS 4,342 SQFT. BULDING PERMIT# 18016-10000-22884	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49410	19041-10000-37750	10 S CHESTER PL Bldg 4	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	34.03079	-118.27732	$0.00 fees due to senate bill 1222 & lb1414[EPLAN] PLAN CHECK FOR NEW ROOF MOUNTED 131.4 KWDC/100KVAAC PV2 SYSTEM CONSISTING OF CENTRAL INVERTER(SE100K) WITH  365 MODULES USING 9730 OPTIMIZERS CONNECTED TO EXISTING 800A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49411	13041-10000-13590	5741 N LE SAGE AVE	91367	3	174B093   158	2041023022	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	34.17501	-118.64198	PV1.  Install roof-mounted solar array, interconnect with existing main service panel.  4.41 kW DC system size.  {18 modules: Trina Solar TSM-245PC05/PA05.18}  {Transformerless inverter: SolarEdge SE5000A-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49412	15041-20001-23805	21514 W SATICOY ST	91304	3	186B105   164	2111005005	(T)(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Apartment			02/02/2018 12:00:00 AM			PC Approved	02/02/2018 12:00:00 AM	ADDRESS	34.20807	-118.59943	Revisions to approved plan.  Approval for changes marked delta 4 and 5 only.  Revised elevator HP rating, luminaire schedule changes, and addition of Romex wiring to system design.  (((Plan check for new building. 29 appartment units. lot area 14,340 sq ft.  PLAN CHECK FOR POWER AND ENERGY.  FA VARIANCE WAS SUBMITTED.Note: Building application filed under 15010-20000-00976)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49413	13041-10000-16343	380 WORLD WAY T18	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	FIRST TIME TENANT SPACE (T18) AT LAX TBIT. POWER AND TITLE 24 PART 6 ENERGY. DUTY FREE STORES (DFS) RETAIL;. EMERGENCY LIGHTING FROM AN INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49414	18041-10001-34912	4470 N WINNETKA AVE	91364	3	165B113    20	2174026008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	34.15251	-118.57107	FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED 11.4KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE 11400A-US) WITH 50 MODULES USING P320 OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49415	11041-10000-15000	7131 W SUNSET BLVD B	90046	4	147B181   635	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			Ready to Issue	08/17/2011 12:00:00 AM	ADDRESS	34.09815	-118.34528	CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT, PLAN CHECK FOR POWER AND ENERGY.  WORK IS ALREADY PERMITED, PLAN-CHECK-ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49416	14041-10000-30151	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM			PC Approved	10/30/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	New lighting for temporary airport security baggage screening area on level 3 of Tom Bradely Int'l Terminal.   Replacement of less than 10% of existing luminaires in baggage pick-up area on level 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49417	18041-10000-24269	461 N ROBINWOOD DR	90049	11	135B141   282	4494016009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.06739	-118.48301	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.16KWdc / 11.04KWac. (48)MODULES-SOLARWORLD SW295MONO(48) MICROINVERTERS- ENPHASE IQ6-60-X-US, $0 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49418	15041-20000-11264	11220 W MOORPARK ST	91602	2	165B173   353	2366008002	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.15023	-118.3753	Plan check for PV roof mounted 28kWac system with 4 inverters(SMA AMERICA SB70000US-12) and 126 modules(HANWHAQ CELLS Q.PRO BFR-G3 260) Permit fee waived due to Senate Bill SB-1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49419	14041-10000-32381	9027 N CANOGA AVE # K	91304	3	195B105    39	2779018036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.23429	-118.59779	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH  NEW LED FIXTURES. TOTAL AREA 2139 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49420	14041-10000-33465	1330 E 16TH ST	90021	14	121-5A211 358	5130015009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.02576	-118.24799	Title 24 plan check only.  Total area = 3652 sq. ft.Remove HID lighting and replace with new LED fixtures (modification in place)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49421	14041-20000-33789	8902 N WOODMAN AVE	91331	6	195B153   475	2640016010	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			PC Info Complete	08/13/2015 12:00:00 AM	ADDRESS	34.23142	-118.43728	Plan check for power and energy. Convert 3rd floor office to medical office, and T.I. to the existing medical office on 1st/2nd floors. OSHPD 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49422	12041-10000-26211	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	PLAN CHECK POWER AND ENERGY. NEW ELECTRICAL SERVICE AND ELECTRICAL EQUIPMENT FOR DODGER STADIUM ELECTRICAL YARD. TWO MEDIUM VOLTAGE SERVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49423	14041-10000-13350	123 S HOBART BLVD	90004	10	138B193  1043	5517012030	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.07303	-118.30563	PV1, INSTALL 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49424	15041-20000-01681	21820 W BURBANK BLVD SUITE 325	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.17228	-118.6032	TI TO AN EXISTING COMMERCIL BUILDING. NEW LIGHTING NEW CONTROLS.  USING EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN SUITE 325.  TOTAL SQUARE FOOTAGE 2513. PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49425	19041-10000-04467	17720 W FULLERFARM ST	91325	12	204B129   388	2734005020	RA-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.25388	-118.52071	PV1, SCOPE OF WORK INCLUDES NEW ROOF MOUNTED PV SYSTEM USING MICROINVERTERS. TOTAL SYSTEM SIZE IS 11.8KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49426	17041-20002-01476	2211 W HILL DR	90041	14	163-5A221  76	5671002002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Expired	09/13/2023 12:00:00 AM	ADDRESS	34.143	-118.21427	changes to an approved set of plans.  changes include (2) 7.6kw inverters, new system size 15.2kw.pv1install roof mounted pv system sized 11.4kw interconected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49427	17041-20000-35688	415 S HARVARD BLVD 1-45	90020	10	135B193   477	5503011024	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.06664	-118.3043	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 29.92 KW$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49428	17041-20001-16298	13850 N GARRICK AVE	91342	7	228B157   230	2503016028	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM			Reviewed by Supervisor	06/01/2017 12:00:00 AM	ADDRESS	34.32383	-118.42564	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (18) micro-inverters, (18) modules, and (1) load center.Expedited per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49429	14041-20001-29806	430 W 6TH ST 2nd flr	90731	15	015B201    89	7455004005	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM			PC Info Complete	11/14/2014 12:00:00 AM	ADDRESS	33.73887	-118.28643	supplemental for addition of second floor energy calculations.  plan check for title 24 energy only.  Plan check for energy only. TI to an existing school building. New lighting (incl. emergency) and receptacles. 4,951sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49430	16041-20000-38919	1633 N LA BREA AVE 1-180	90028	4	147B181  1177	5548008***	C4-1VL-SN, R4-1VL	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	12/12/2016 12:00:00 AM	ADDRESS	34.10068	-118.34528	Plan check for energy only. TI for fitness center, wifi lounge, parcel pickup area, and pool lounge for mixed use building. New lighting (incl. emergency). 4,043sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49431	14041-20000-05217	5808 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.97391	-118.41962	ROOF-MOUNTED,PV1 SINGLE FAMILY DWELLINT. TOTAL SYSTEM SIZE 3KW AC USING 9 MODULE.S TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49432	17041-20001-05544	17836 W CATHEDRAL PL	91316	5	165B129   207	2184029008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.14922	-118.52188	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv system, roof-mounted on SFD. Interconnect with 400A MSP.Existing 15kW pv system on SFD. New system is 3kW ungrounded. (10) 315W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49433	18041-10000-17858	501 W 190TH ST	90248	15	060B201   140	7339008035	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Closed	02/21/2023 12:00:00 AM	ADDRESS	33.86259	-118.28248	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49434	11041-10000-25175	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			11/23/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.10686	-118.33085	P/check for compliance with lighting reqmts. of T-24 including emergency egress lights and exit signs (ONLY) , @ suite #101.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49435	18041-10000-30235	20121 W DEVONSHIRE ST	91311	12	204B113    51	2707023021	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.25742	-118.57217	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49436	12041-10000-25544	4024 N RADFORD AVE PV2	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	05/22/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.14441	-118.39252	"Note to LADBS Staff: Permit for buildings 9,10,11,12 (THIS APPLICATION) is under the ""Inspection"" fee period.PV-2, NEW 502KW ROOF MOUNTED PV SYSTEM ON THE CBS STUDIO BUILDING. Permit for BUILDING 21, 22, 23 has been paid on a separate application. Please charge permit for buildings 9, 10, 11, 12 on inspection fee period. Permit for buildings 21, 22, 23 has been paid for on 13041-20000-00414"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49437	18041-20000-33839	20708 W BEECH CIR #293	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.29258	-118.58458	pv1install roof mounted pv system sized 2.8KW AC interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49438	14041-10000-07089	9713 W OAKMORE ROAD	90035	5	129B165   745	4307016006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Expired	05/05/2016 12:00:00 AM	ADDRESS	34.04779	-118.39918	PV1, INSTALL  A 7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000-US-ZB-U(28)MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49439	16041-20000-34773	9811 N FULLBRIGHT AVE	91311	12	201B113   360	2748009019	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.24842	-118.57813	PV1.  Installation of 3.0 kW roof mounted grid tied photovoltaic system.  (10) modules with (1) 3.0 kW central inverter with power optimizers.  (E) 6 kW PV system also on site.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49440	14041-10000-17551	13513 W VANOWEN ST	91405	2	183B157   960	2328013012	R1-1, R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Expired	07/18/2018 12:00:00 AM	ADDRESS	34.19409	-118.42732	plan check for power and energy. no t24 provided. BLDG#13010-20000-04331: New 3-story, 8 unit apartment with attached garage. PROVIDE FIRE ALARM VARIANCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49441	13041-10000-33665	526 S SAN PEDRO ST	90013	14	127-5A213 317	5147025900	PF-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			PC Approved	12/04/2013 12:00:00 AM	ADDRESS	34.04338	-118.24419	TITLE 24 PART 6 ENERGY LIGHTING WORK FOR SINGLE STORY COMMERCIAL BUILDING. SCOPE OF WORK IS < 400A. TOTAL AREA IN SCOPE OF WORK IS 2500 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49442	16041-20000-18713	4118 W LOS NIETOS DR	90027	4	150B201   401	5591011002	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.10903	-118.28032	Plan check for a PV1 roof-mounted PV system. System size is 8 kWac and consists of (32) modules, (32) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49443	16041-10000-01082	950 S BOYLE AVE	90023	14	124-5A221 311	5189001040	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.03422	-118.21919	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE/SHOWROOM AREA). SCOPE INCLUDES TWO NEW PANELS, LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 6911 SQ. FT.NOTE: Permit fees paid under PCIS#15041-10000-22215/X15LA12725	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49444	19041-10000-09102	445 S FIGUEROA ST STE 2650	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLAN CHECK FOR T-24, Tenant improvement work on ST. 2650. Scope of work includes new lighting and receptacles. Total  Area = 4057 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49445	13041-10002-35796	2595 S HOOVER ST	90007	8	123A201    42	5055022034	C4-1VL-O, QC1.5-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM			PC Approved	09/26/2016 12:00:00 AM	ADDRESS	34.03206	-118.28429	Revision to approved set of plans due to change in fault current values. Changes under delta 2. *****PLAN CHECK FOR POWER AND ENERGY FOR EW DEVELOPMENT INCLUDING 46 RESIDENTIAL UNITS, 3 & 4-STORY AND +/- 7,000 SQ.FT. OF COMMERCIAL USE.BUILDING P # 1301010000-04326	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49446	15041-10000-27524	501 S SPRING ST	90013	14	129A211   112	5149034006	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.04739	-118.24992	917 sq. ft. single story restaurant TI.  Plan check for energy.  Existing permit already filed for this project under 15041-10000-20354	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49447	17041-10000-38063	8810 N TAMPA AVE	91324	12	195B121   511	2784003069	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	05/15/2019 12:00:00 AM		Issued	05/15/2019 12:00:00 AM	ADDRESS	34.23097	-118.55317	T-24, PC FOR ENERGY ONLY. T.I. TO EXISTING COSTCO (MEAT PREP AREA). SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 541 SQ. FT. B#17016-10000-31325	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49448	13041-10000-04831	20308 W STRATHERN ST	91306	3	189B113   511	2107025026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03, 1341.04	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	ADDRESS	34.21546	-118.5757	photovoltaic system for single family dwelling. 2 story dwelling. total size 4.41kw. using 18 modules and single transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49449	11041-10003-20630	1118-1120 E LAKE ST BLDG 25	90291	11	111B145   161	4243001039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/10/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.00361	-118.45925	LINCOLN PLAZA APARTMENT BUILDING PROJECT. ((((7/10/14 MZ addition of 3 20amp car chargers)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49450	14041-10000-13530	1516 N MERCURY DR	90042	14	157-5A229 630		R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.12729	-118.18886	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 2.59KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49451	19041-20000-03590	21600 W OXNARD ST 860	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 1,715 sq ft. B#19016-100000-01894	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49452	19041-20002-02047	8352 N COOPER PL	91306	3	192B109   955	2780005077	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.22201	-118.58696	03-14-2019 Changes to an approved set, changes include addition of 70A circuit breaker to main panel. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49453	17041-10000-28064	982 S CATALINA ST	90006	10	129B197   115	5078007019	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.05324	-118.29462	FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49454	14041-10001-04290	3607 S TROUSDALE PKWY 4th floor	90089	9	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.02013	-118.28566	plan check only. CHANGES TO APPROVED: LIGHTING UPDATED AND RECEPTACLES added. Changes are in clouds.  Plan check for power and energy. First time tenant.(USC university)Total area 11902 SQ FT. One New panel. Changes on plan include removal of emergency lights from classroom 404D and conference 401.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49455	18041-20000-20158	152 N MARIPOSA AVE	90004	13	138B197   673	5518010014	R3-1	Central	Wilshire	Wilshire Center-Koreatown		2112.01	Electrical	Electrical	Apartment			05/31/2018 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/25/2023 12:00:00 AM	ADDRESS	34.07436	-118.29926	Plan check for new appartment building 5 units and 3 story building. Total area: 6337 sq ft.Fire alarm has not been generated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49456	18041-10000-35667	4551 S GLENCOE AVE 140	90292	11	105B153   615	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Issued	10/01/2018 12:00:00 AM	ADDRESS	33.9844	-118.43407	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR OFFICE REMODEL TO CONSIST OF NEW OFFICES, NEW CONFERENCE ROOM, NEW BREAK ROOM, NEW STORAGE ROOM, NEW CEILING, NEW FINISHES THROUGHOUT. - TOTAL AFFECTED AREA = 6215 SF B#18016-10000-30234	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49457	12041-20000-15726	832 E 60TH ST	90001	9	105B209    86	6007007003	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	33.98557	-118.26002	600 Service upgrade.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49458	15041-20000-10706	10181 N AMBOY AVE	91331	7	204B157   747	2646022032	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.25534	-118.42573	Plan check for a PV1 roof-mounted PV system. System size is 3.4 kWac and consists of (16) modules, and (16) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49459	17041-10002-40640	8500 W BEVERLY BLVD #117	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	Changes to an approved set of plans. All changes are clouded under delta 10. Changes include revising lighting floor plans, revising panel schedules, and revising Title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49460	14041-20000-18610	10500 N AIRPARK WAY	91331	7	204B161     2	2536017906	OS-1VL, PF-1VL-O, [Q]MR2-1VL-O, [T][Q]MR2-1VL-O	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			Plans on Hold	09/16/2014 12:00:00 AM	PIN	34.2607102	-118.41087697	PV2 COMMERCIAL ROOFTOP PV SYSTEM. SYSTEM SIZE 342KW. USING TRANSFORMERLESS INVERTERS. NEW PV ONLY SERVICE. 800A 480V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49461	13041-20000-08042	1075 N WESTERN AVE 101-109	90038	13	144B193   779	5536019024	[Q]C2-2D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Issued	03/28/2013 12:00:00 AM	PIN	34.09038224	-118.30940652	New fire alarm system for an existing single-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49462	17041-20000-46109	4415 N WESTCHESTER DR	91364	3	166-5A109 121	2174013014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2017 12:00:00 AM			PC Approved	01/02/2018 12:00:00 AM	ADDRESS	34.15069	-118.58505	Plan check for a PV1 ground-mounted PV system. System size is 17.9 kWac and consists of (56) AC PV modules and (1) load center.Note: Building application for ground-mounted solar array has been generated under 16020-20000-03101. See application comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49463	11041-10000-26572	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Closed	07/29/2015 12:00:00 AM	ADDRESS	33.78054	-118.23195	NEW 5OKVA UPS SYSTEM FOR VALERO SUBSTATION #1. NEW 800A SWITCHBOARD, XFMRS, PANELS, CKTS, AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49464	11041-10000-23664	808 N NORTH SPRING ST	90012	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.06198	-118.23674	Interior work to an existing Shell of an 123 unit apartment building.  Plan check for POWER and ENERGY.  Variance to seperate fire alarm will be filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49465	17041-10000-24755	8360 W MELROSE AVE 3rd Floor	90048	5	141B173   498	5528016060	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.08338	-118.37235	PC FOR OFFICE TI ON 3RD FLOOR OF OFFICE BUILDING FOR TITLE -24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA 1781 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49466	13041-20000-21124	14326 W CHANDLER BLVD PV1	91401	4	171B153   130	2248016***	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.16822	-118.44508	INSTALL SOLAR PHOTOVOLTAIC SYSTEM (2.6KW)  MICROINVERTER STANDARD PLAN. USING 10 MODULES. PLAN CHECK ONLY. PERMIT ALREADY ISSUED UNDER EXPRESS PERMIT 13041-20000-19523	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49467	16041-10001-13491	9301 N TAMPA AVE STE 218	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			PC Approved	08/19/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Relocating existing track lighting. Installing  one new circuit for outdoor heating.PC FOR ENERGY AND POWER. T.I FOR  RESTAURANT I.I.. MAXIMUM OCCPANCY MORE THAN 100. TOTAL AREA 5,927 sq.ft B#16016-10000--08439	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49468	10041-20000-08128	8403 N FALLBROOK AVE	91304	12	192B097   589	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.22129	-118.62628	PLAN CHECK POWER AND ENERGY TI IN OFFICE BUILDING. NO NEW LOAD ADDED IN EXISTING PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49469	14041-10000-05034	1500 E LOMITA BLVD	90744	15	036B209    10	7426006001	[Q]M3-1VL, [Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM			Reviewed by Supervisor	03/12/2014 12:00:00 AM	ADDRESS	33.79983	-118.25006	PLAN CHEKCK FOR POWER. NEW 125 A PANEL. HAZARDOUS AREA.BUKDING APPLICATION NUMBER: 14020-10000-00424{{DESCRIPTION FROM BUILDING:  INSTALLATION OF (1) 6000 GALLON ABOVE GROUND STORAGE TANK TO CONTAIN DIESEL FUEL AND (1) PRE CAST TANK PAD WITH CONTAINMENT CURB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49470	09041-10001-17341	1616 N LA BREA AVE	90028	13	147B181   377	5548012046	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			02/11/2011 12:00:00 AM			PC Approved	02/11/2011 12:00:00 AM	ADDRESS	34.1002	-118.34456	REVISIONS TO APPROVED SET OF PLANS- ADDED AN EMERGENCY LUMINAIRE  FOR THE DRIVE WAY ON EACH LEVEL ; CHANGE THE LAYOUT OF SOME UNITS; FOR THOSE UNITS ON THE 4TH FL.THE LOFT LEVEL WAS REMOVEDNew 56-unit, 4 sotry mixed-use building.  Power and energy.  A variance has been filed to separate the fire alarm plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49471	14041-10000-18647	15963 W STRATHERN ST	91406	6	189B141    23	2206005021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Public Safety Only			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.21581	-118.48145	UPGRADE FIRE ALARM PANEL AND ADDED NEW FA DEVICES TO ADDITION OF LA BREA BAKERY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49472	15041-10000-26362	335 W 31ST ST STE D	90007	9	120A203   127	5122018021	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.0231	-118.27594	PC FOR T-24. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49473	17041-20000-45607	3322 N SCADLOCK LANE	91403	4	159B145   468	2279028013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.13153	-118.46782	pv1install roof mounted pv system sized 10kw interconnected with msp.effeciency rating 11.83kw AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49474	13041-10001-07408	1340 S ABBOT KINNEY BLVD	90291	11	108B145  1347	4238004039	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	33.99073	-118.46681	ENERGY PLAN CHECK RETAIL CHANGES TO APPROVED SET OF PLANS. MINOR T24 CHANGES.(((((((04/19/2013: SUBMITTAL 2 TO BE GENERATED AT TIME OF APPROVAL, DEPENDENT ON NUMBER OF HOURS SPENT DURING VERIFICATION)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49475	12041-10000-17844	333 S GRAND AVE	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.05271	-118.25179	REMODELING OF OPEN OFFICES AND PRIVATE OFFICES IN SUITE 2200PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49476	16041-30001-39250	1260 N VINE ST	90038	13	144B189   143	5534001400	C2-1-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.09406	-118.32645	12/15/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance forms. *****Previous Work Description*****PC for energy only. TI on existing restaurant space (Pollo Loco store #5386). Adding new indoor and outdoor lighting. Total sqft=5130.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49477	19041-20000-44034	22815 W CALIFA ST	91367	3	177B097   598	2041019005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.1775	-118.624	PV1.  Install 13.32 kW roof mounted grid tied PV system.  (36) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49478	14041-20000-34874	11826 W PALMS BLVD	90066	11	117B153   987	4249018022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.0141	-118.43272	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 10 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (40) SOLAR WORLD SW270 MONO MODULES(1) SOLAR EDGE 10,000A-US INVERTER(40) SOLAR EDGE P300 SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49479	15041-10000-16712	866 S TREMAINE AVE	90005	4	132B185   339	5090004017	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2015 12:00:00 AM			Verifications in Progress	07/23/2015 12:00:00 AM	ADDRESS	34.05909	-118.33638	PV 1, 45 MODULES AND 45 MICRO INVERTERS. TOTAL SIZE: 10.8(45) SW 280 MONO(45) ENPHASE M250	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49480	10041-20001-01445	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM			PC Approved	06/02/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	PLAN CHECK ONLY. REVISION TO POINT OF CONNECTION MARKED DELTA 2 (FIELD CHANGE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49481	10041-10002-05231	2930 E WHITTIER BLVD	90023	14	123A223   248	5189004040	C1-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2047.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	34.03069	-118.20803	Plan check power and energy for new service upgrade from 400A to 800A. New switchboards, panels, equipments, and ckts.(((((( The # 10041-10002  05231 is plan check only permit is already pulled under 10041-10000-05231.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49482	13041-20000-10101	5700 N CANOGA AVE flr 5	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.17365	-118.59715	"Full plan check for commercial. Addition to an existing building (addition is to 5th floor). highest floor is 5th floor. Addition of ""optional"" 750kW generator (other 750kW generator existing). Viking River Cruises. Not methane zone. PC fees per applicant."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49483	10041-20000-11996	555 W 5TH ST 7th Floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check T-24 Enegy for general/emergency lighting on the 7th floor. Add fixtures and relocate fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49484	11041-20000-03619	127 S SAN VICENTE BLVD Delta 40-Shell	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM			PC Approved	02/25/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision to approved plans shell building to reflect changes done oshpd plans part of the building is under oshpd jurisdiction  delta 40	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49485	16041-20000-16802	333 S GRAND AVE SUITE 2280	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. SUITE 2280.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49486	18041-20000-01782	505 W CENTURY BLVD	90044	8	091-5A201  99	6054021017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	33.9457	-118.28312	new single story commercial building (7 eleven) 800 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49487	19041-10001-15365	5905 W GRACIOSA DR	90068	4	153A191   344	5580011015	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM			PC Approved	07/10/2019 12:00:00 AM	ADDRESS	34.11285	-118.31824	"DELTA ""1"" CHANGES TO APPROVED PLANS FOR CHANGING THE LOCATION OF THE INVERTER. <<<NEW 4.56 KW ROOF MOUNTED PV SYSTEM WITH 16 PANELS ON A SINGLE FAMILY HOME.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49488	18041-10000-11913	15424 W CABRITO ROAD	91406	6	189B145   264	2654039013	M1-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.21664	-118.46898	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49489	18041-20001-43438	6536 N GAVIOTA AVE	91406	6	180B141   506	2233017029	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.1897	-118.48128	Expedited plan check fee.PV1.  Install 11.52 kW DC roof mounted grid tied PV system.  (32) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49490	15041-10000-42938	11150 W SANTA MONICA BLVD #1020	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.04704	-118.44563	OFFICE TI. NEW LIGHITNG. PC FOR T24 ENERGY ONLY. WORK DONE IN SUITE 1020	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49491	18041-20000-16085	767 S ALAMEDA ST #184	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	Plan check for Title 24 only in existing space T.I. restaurant total newly added load less than 400A. Total area: 1,101 sq ft.B#18016-10000-10007	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49492	17041-20000-22666	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.30584	-118.47951	Remodel of (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49493	16041-10000-45015	8211 N REMMET AVE	91304	3	189B105    35	2110019022	[Q]CM-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.05	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.21802	-118.60044	PC for energy only. Change of use from office to charter school. Adding a new panel, newly added laod is less then 400 amps. Total area: 10524 (indoor only).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49494	11041-10000-21467	1290 S LA CIENEGA BLVD	90035	5	129B173    20	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	34.05352	-118.37593	TI TO AN EXISTING RETAIL SPACE.  PLAN CHECK IS FOR ENERGY ONLY, WITH  EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49495	19041-10000-13136	4840 S ALLA ROAD	90066	11	105B157   569	4223008010	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	33.98258	-118.42922	Plan check for a new fire alarm system located in a new 2-story office building (core and shell only). Scope includes (1) fire alarm panel, (1) control panel, and (48) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49496	19041-20000-05464	23222 W OXNARD ST pv1	91367	3	177B093   785	2041006026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.17847	-118.6329	pv1install roof mounted pv system sized 8.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49497	17041-20001-06556	2205 S CRENSHAW BLVD	90016	10	126B185  1193	5061020047	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM			PC Approved	03/08/2017 12:00:00 AM	ADDRESS	34.0382	-118.33229	Expedite. 5.23kW single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49498	18041-10000-45088	380-384 WORLD WAY MSC-BHS	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	01/28/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	Power plan check for baggaging equipment located in the new terminal (Midfield Satellite Concourse), Building A. Scope include multiple motor under each ckt from subcontrol panel and main control panel.LAX project; Applicant request Mehdi for the application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49499	14041-20000-13693	2122 N NORTH BROADWAY	90031	1	138A221   111	5204006007	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.07333	-118.21814	Plan check cover for all 10490 square footage.PLAN CHECK FOR ENERGY ONLYSingle story commercial building, tenant retail space (Goodwill). All lighting indoors is new, including Emergency lighting. !!!!!Square footage incorrectly stated on forms, undercharged fees. Charge for remaining floor area on submittal 2.!!!!!!!!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49500	18041-10000-06707	312 W 5TH ST 103	90013	14	129A211   270	5149002***	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04822	-118.25128	PC for energy only, Change of use from Retail to Retail/Take-Out Restaurant. Scope of work includes new lighting and receptacles. Total Sq. ft. 1198	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49501	17041-10000-18829	10250 W SANTA MONICA BLVD 9200	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan Check, TI at Westfield Century City, 'Lette Macarons'.  Ste. 9200, 296 sq.ft area. Service and Dist. board are existing.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49502	16041-10000-06545	3322 W WILSHIRE BLVD	90010	10	132B197    69	5094007021	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.06156	-118.29485	FULL PC FOR POWER AND ENERGY. CHANGE OF USE OF  (E) 4 STORY HOTEL & OFFICE BUILDING TO  MIXED USE (E) OFFICE (ON FIRST FLOOR) AND  17 UNITS  APARTMENT BUILDING & TI TO (E) OFFICE. TOTAL AFFECTED AREA IS 8200 SQ. FT.  FIRE ALARM VARIANCE TO BE SUBMITTED AT A LATER TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49503	15041-10000-00403	2078 S COMPTON AVE #B	90011	9	118-5A213 363	5118025005	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.01834	-118.24455	Plan check T-24 only for retrofit existing lights to LED with retorfit kits. Total area: 9840SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49504	19041-10000-02767	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM			Corrections Issued	01/29/2019 12:00:00 AM	ADDRESS	34.05069	-118.24861	PLAN CHECK FOR TITLE 24 ONYL FOR - RENOVATION AND ADDITION OF TOILET FIXTURES TO EXISTING BASEMENT TOILET ROOMS AND REBUILDING OF EXISTING BASEMENT HISTORIC EXIT STAIR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49505	18041-10000-21702	5955 N LINDLEY AVE	91356	3	177B125   762	2157013144	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.17874	-118.52748	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49506	14041-10000-04950	4050 N HARCLARE LANE	91436	5	165B137   584	2291016021	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Expired	04/08/2016 12:00:00 AM	ADDRESS	34.14445	-118.49136	PV1, INSTALL 6.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE6000A-US-ZB-U(27) MODULES: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49507	17041-20001-14137	5747 N RHODES AVE	91607	2	174B165   283	2340014009	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM			PC Approved	05/26/2017 12:00:00 AM	ADDRESS	34.17522	-118.40321	Expedited plan check fee per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49508	18041-20001-33399	7355 N VARNA AVE	91605	2	186B157   379	2328027006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Approved	08/29/2019 12:00:00 AM	ADDRESS	34.20459	-118.42485	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY. RELOCATION OF MAIN SWITCHBOARD. <<<Plan check for power and energy. Project site is a 1-story warehouse. Work includes a 600 Amp service and a total lighting area of 11,400 sq. ft.Note: Building permit has been issued under 17010-20000-05184>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49509	15041-10000-43498	4676 ADMIRALTY WAY #550	0	5									Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM			PC Approved	12/24/2015 12:00:00 AM				ENERGY PLAN CHECK FOR A PRE-ACTION DETECTION CONTROL SYSTEM. EQUIPMENT LAB ROOM. #742.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49510	12041-10000-14552	2805 W AVENUE 30	90065	13	150B213    65	5457006019	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.02	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	ADDRESS	34.11126	-118.24209	Plan check new roof mounted 3.12KW photovoltaic system (transfomerless inverter) with solaredge DC-DC powerbox for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49511	15041-20000-23960	17854 W HARTLAND ST	91335	3	183B129  1000	2122014018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.19464	-118.52242	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49512	10041-10000-16866	1261 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/27/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.05166	-118.22569	Solar voltaic system installed on the roof of the building.  Consists of 12 modules, 12  A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49513	18041-20000-24583	1806 N GRAMERCY PL	90028	13	150A193   560	5544003034	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			07/02/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/10/2021 12:00:00 AM	ADDRESS	34.10364	-118.31211	Plan check for power and energy. Project site is a 4-story, 10-unit apartment building. Work includes a 1,000 Amp service and a total lighting area of 11,813 sq. ft.Note: Building permit has been issued under 14010-20000-02226	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49514	16041-30000-29865	7900 N VALLEY FLORES DR	91304	12	189B089   206	2020011023	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.21402	-118.64607	Plan check for PV roof mounted system. System size: 7.6kW with 34 modules and 1 inverter(7.6kW) Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49515	17041-10000-29444	5733 N LAUREL CANYON BLVD	91607	2	174B165   346	2340026032	R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.17474	-118.3967	REMOVE EXISTING (11) HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 5510 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49516	17041-20000-08115	18300 W LAHEY ST	91326	12	210B125   339	2715029027	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.27257	-118.53195	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49517	13041-10000-36099	901 E 12TH ST	90021	14	123A211    87	5132014001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	01/12/2015 12:00:00 AM		Issued	01/12/2015 12:00:00 AM	ADDRESS	34.03208	-118.24959	Plan chek for power and energy for a shopping center with basement and 2 stories.,3rd floor and roof as parking. New 4000 amp service. 54 new panels. Total area for indoor lighting 77617 sq ft and outdoor lighting 3095 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49518	16041-20001-01806	6415 W RIGGS PL	90045	11	102B165    61	4110013030	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	33.97882	-118.39928	Expedited per customer request.PV1. Install roof mounted PV system sized 8 kW. Interconnected with main servive panel.(32) Sunmodule Plus SW 286 Modules(32) Enphase M250 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49519	14041-10000-12495	4529 N AGNES AVE	91607	2	168B165  1027	2364001013	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.15296	-118.3955	PV1 6.75KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(2) inverters: {PVI-3.0-OUTD-US }]. [(27)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49520	15041-10000-13995	4816 W FOUNTAIN AVE	90029	13	147B197  1139	5540015017	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.09524	-118.29387	MAIN SERVICE UPGRADE, 800AMP, TO (E) BUILDING.  PC FOR POWERORIGINAL PLAN WAS APPROVED FOR 400 AMP SERVICE.  PANELS AND CIRCUITS ARE EXISTING TO REMAIN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49521	13041-10001-32288	3718 N CROWNRIDGE DR	91403	5	162B141   370	2280008018	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.13786	-118.47439	Expedited RSES plan check per applicant request.(((PV1, Install 15 kW DC roof-mounted solar array, interconnect with service panel. Transformered inverter. Fronius IG Plus A 11.4. 60 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49522	19041-10000-25051	6055 W PICO BLVD	90035	5	129B173   187	5087015021	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Apartment			07/03/2019 12:00:00 AM	10/19/2023 12:00:00 AM		Issued	10/19/2023 12:00:00 AM	ADDRESS	34.05279	-118.37237	New 5-story, 125-unit Apartment, over 1-story Commercial and Parking over 1-level subterranean parking with a new 3,000 Amp ServiceBulding Permit: 18010-10000-00206	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49523	13041-20000-21258	2121 S SAWTELLE BLVD	90025	11	126B153   971	4260002029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			Corrections Issued	08/08/2013 12:00:00 AM	ADDRESS	34.03889	-118.44213	pc for t24 energy only. original set of plans were lost/stolen. this application is for new plan check and restamp copy set.  permit has already been issued under application # 13041-10000-15374	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49524	18041-20002-27329	8620 N TAMARACK AVE	91352	6	195B169   430	2631018079	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.2283	-118.38502	02/15/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to reflect field changes and installation.2/4/19changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.*****Original Work Description*****change of use from warehouse/office to hydroponic agricultural enterprise/office.  (E) 2000A 480Y/277V 3ph-4w and 400A 240/120V 1ph-3w services with new distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49525	17041-10000-19821	11134 W WICKS ST	91352	7	201B173   249	2538017002	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			Reviewed by Supervisor	06/19/2017 12:00:00 AM	ADDRESS	34.24867	-118.37346	Installation of new roof mounted solar PV system on existing single family dwelling.  Two Delta Soliva 5.2 TL inverters with 22 Solarcity Standard SC325 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49526	18041-10001-21259	3029 S 11TH AVE	90018	10	120B185   598	5051033022	R2-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.02673	-118.32943	Installation of roof-mounted solar 3.4 (DC) KW, PV system, with 11 PV modules on a single family dwelling.Permit was issued under 18041-90000-21259	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49527	19041-20000-25355	10900 W WILSHIRE BLVD ste 340	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	02/04/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.05848	-118.44419	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49528	19041-10000-21107	263 W 7TH ST	90731	15	015B201   801	7455022***	CM-2D-CPIO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	33.73765	-118.2828	Energy plan check for a salon T.I. Scope includes new lighting and equipment with a total lighting area of 1710-SQ FT.Note. permit fee is paid under 19041-40000-10037.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49529	15041-10000-30305	2211 W CAMBRIDGE ST	90006	10	126B193   101	5074010011	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.04464	-118.30652	PV1 6KW AC roof-mounted system with (20) Sunpower SPR-327-NE modules and (1) Power-One PVI-6000-OUtd inverter interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49530	13041-20000-36139	19730 W MARIPOSA CREEK WAY	91326	12	213B113   158	2701028012	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.28234	-118.56547	New Ungrounded PV system on the roof of an existing single family dwelling.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49531	19041-20000-31561	323 S SYCAMORE AVE	90036	4	135B181   252	5507008005	R1R3-RG	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	08/31/2019 12:00:00 AM	ADDRESS	34.06819	-118.34306	PV1 PLAN CHECK FOR NEW ROO PV ON EXISTING SFD. SYSTEM SIZE IS 8.91 KW DC/7.573 KW AC. SCOPE OF WORK CONSISTS OF (27) PV MODULES WITH OPTIMIZERS AND A 10KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49532	10041-10000-25741	375 N LA CIENEGA BLVD 1-125	90048	5	138B173    80	4337012038	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Apartment			12/29/2010 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.07806	-118.37692	New 5 story 125 units appartment bldg. EPC is for Power & Energy. (Varience for a separate fire alarm plan was paid)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49533	14041-20000-08409	6525 W QUINTON LANE	91042	7	201A203    79	2570020015	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.24665	-118.27391	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 6 KW DC.(24) CANADIAN CS6P-250(24) ENPHASE M215-60	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49534	19041-10000-33079	4370 S HOOVER ST	90037	9	112-5A201  48	5019009900	PF-1	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.00408	-118.28693	Plan check for a fire alarm system located in a fire station. Scope includes (1) fire alarm panel, and (44) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49535	14041-20000-28685	22601 W SANTA SUSANA PASS ROAD	91311	12	210B101    11	2723002018	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.27227	-118.6163	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING/RELOCATING LIGHT FIXTURES AND CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.  3301 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49536	19041-10000-49981	6935 W MELROSE AVE	90038	5	141B181   579	5525007003	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.08357	-118.34258	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 (OUTDOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49537	18041-20000-09407	15311 W SATICOY ST	91406	6	186B145   135	2222013043	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.20859	-118.46667	Plan check for Title 24 only. Project site is an existing car wash. Project scope is car wash bay lighting. Total lighting area = 2,310 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49538	15041-10000-42223	2219 N GLOVER PL	90031	13	144B213   639	5445028054	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.09006	-118.23759	3kw ac pv system. using central inverter. nonstandard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49539	14041-10001-33141	9841 N AIRPORT BLVD Suite 812	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	33.94647	-118.38626	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO THE ENERGY CALCS AND LIGHTING FIXTURES.Plan check for Title 24 only. Total lighting area = 4960 sq. ft. Project site is commercial (single suite on the 8th floor of a high-rise office building).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49540	17041-10000-17273	3521 S 7TH AVE	90018	10	120B189  1089	5044016026	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.02347	-118.3249	Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 6.6 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49541	17041-10000-23256	6250 N LANKERSHIM BLVD	91606	2	177B169   159	2335029014	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Issued	07/11/2017 12:00:00 AM	ADDRESS	34.18436	-118.38616	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49542	16041-10000-00585	1818 S GLENDON AVE	90025	5	129B153   554	4321001***	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.04953	-118.43499	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(31) SOLARWORLD PLUS SW 260 WATTS(31) P300 OPTIMIZERS (1) SOALREDGE SE7600 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49543	15041-10000-13707	1817 S SOTO ST	90023	14	117A219    92	5169029017	M3-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.01594	-118.22017	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 33576	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49544	18041-10000-12499	1541 N WILCOX AVE	90028	13	147A187    48	5547017003	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	07/24/2021 12:00:00 AM	ADDRESS	34.09913	-118.33128	SUBMITTAL FOR 3 LEVEL GUARAGE STRUCTURE AS A PART OF HIGHRISE HOTEL. THIS IS A PLAN CHECK ONLY FOR CONDUITS. APPLICANT TO OBTAIN CONDUIT AND PERMIT WITH MODIFICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49545	15041-20001-11906	5695 S GOLDENEYE CT UNIT 1	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	33.97898	-118.41086	Expedite per applicant request********Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL APPLY TO UNIT # 2 AND #3 OF ADDRESS 5695 GOLDENEYE CORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49546	18041-10000-33466	7286 N CIRRUS WAY	91307	12	186B093   625	2027009022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.20277	-118.63685	PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 7.0 KW AC SCOPE INCLUDES 28 MODULES WITH 28 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49547	15041-20000-32362	8114 S AVALON BLVD	90001	9	099B205  1163	6029009032	R3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2398.01	Electrical	Electrical	Apartment			09/30/2015 12:00:00 AM			Reviewed by Supervisor	10/27/2015 12:00:00 AM	PIN	33.96506237	-118.26482088	Plan check for power and energy. Project site is a new 3-story, 16-unit apartment building. Building is 2 levels of residential over 1 level of above-ground parking. Overhead service size is 800 amps. Total indoor lighting area = 11,715 sq. ft. Outdoor lighting area = 2,000 sq. ft.Note: Building application has been filed under 15010-20000-02149	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49548	16041-10000-05085	8228 N NESTLE AVE	91335	12	192B125   718	2102022013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.22027	-118.53075	PV1 roof mounted solar system installation to a single family home with a central inverter rated at 6kw and 30 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49549	12041-10000-25391	4343 N BEEMAN AVE	91604	2	165B161   396	2375003042	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.14975	-118.40744	New 6.37 kw roof mounted PV for a single family using M215 microinverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49550	13041-10000-00115	7651 N SAN FERNANDO ROAD	91352	2	186B177   563	2466036***	M2-1, [T][Q]M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM	01/03/2013 12:00:00 AM		Issued	01/03/2013 12:00:00 AM	ADDRESS	34.20899	-118.35712	This is a on story bldg, equipment hook up, 3 xfmr, 5 panels, new and existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49551	19041-10000-16086	1150 S OLIVE ST 9TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.03962	-118.26181	Full PC for 9th Floor of an office TI. Scope of work inclues instaling new panels and equipment. The affected area is 18762 SQFT. Three building numbers are given for the three floors.B#1: 19016-10000-12257 (9th floor)B#2: 19016-10000-12315  (26th floor)B#3: 19016-10000-12301 (10th floor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49552	16041-10000-33519	17361 W SUNSET BLVD	90272	11	126B117   614	4416003015	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.03993	-118.55459	PC for energy only to an existing building. Change of use from bank to market. Installing new lighting and power. Total sqft = 1548	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49553	11041-10000-09699	1054 S ROBERTSON BLVD	90035	5	132B169   376	4332016024	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.00	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.05762	-118.38347	INSTALLATION OF A NEW FIRE ALARM SYSTEM IN A DAYCARE CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49554	18041-10000-05302	14753 W DELANO ST	91411	6	178-5A149 211	2241015901	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.18278	-118.45489	PC for T24 only for removal of HID fixtures and replace with new LED fixtures. Total are 5750sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49555	11041-10000-23285	6300 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM			PC Approved	12/02/2011 12:00:00 AM	ADDRESS	34.18492	-118.59722	T.I. to an existing office building on the 1st, 5th, and 16th floors.  Per applicant, load change is less than 400A.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Full plan check may be required, subject to field verification.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49556	19041-20000-12864	11606 N LYSTER AVE	91326	12	213B121   230	2871011016	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.28219	-118.54168	PC FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE 8.28KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (23) HYUNDAI 360W PV MODULES WITH SOLAR EDGE P400 OPTIMIZERS, AND A SE7600H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49557	09041-10001-23247	1347 N HIGHLAND AVE	90028	4	147A185   273	5548024043	C2-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM			PC Approved	09/13/2010 12:00:00 AM	ADDRESS	34.09571	-118.3389	REVISIONS TO APPROVED LIGHTING PLANS; CHANGE LUMINAIRES IN RETAIL AREAS ON 1ST THRU 3RD FLOORS TO RECESSED IAN LUMINAIRES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49558	16041-20003-36316	717 S MORENO AVE	90049	11	126B141   235	4264007051	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	34.04281	-118.48391	12.14.2016 - Plan check for modifications to approved set. Change inverters to more modern version of same brand, type (ungrounded), and rating (SMA Sunny Boy 7.0-US ==> SMA Sunny Boy 7000TL-US). Changes clouded.======pv1install roof mounte pv system sized 14kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49559	14041-20000-06565	2010 S CENTURY PARK	90067	5	132B161    28	4319001803	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	PIN	34.06026625	-118.41283172	Install new emergency ATS for new elevator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49560	18041-20001-00027	4601 N NOMAD DR	91364	3	168B113   393	2175018028	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.15534	-118.56877	expeditepv1install roof mounted pv system sized 11.7kw interconnected wtih msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49561	12041-10000-11164	700 W WORLD WAY #7G	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	PIN	33.94153561	-118.3984113	Plan check power and energy for B-Grill restaurant Space#7G Terminal 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49562	14041-10000-13075	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Closed	08/02/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	Full Plan check for new 5 stories parking structure,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49563	15041-10000-18131	10990 W WILSHIRE BLVD STE 800	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.0577	-118.44711	Energy plan check for an office T.I located at a high rise building; All lighting is reconnected from existing circuits, no new circuit involved.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49564	19041-20001-20614	11663 N SHEFFIELD WAY	91326	12	213B125    84	2870018009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2019 12:00:00 AM			PC Approved	06/14/2019 12:00:00 AM	ADDRESS	34.28351	-118.53167	06/14/2019 Changes to an approved set of plans. MCB is no longer being derated. MSP is being upgraded. All changes denoted in red text.*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWdc/10.2 kWac-CEC and consists of (32) AC PV modules and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49565	15041-20000-26133	1144 S WOOSTER ST	90035	5	132B169  1123	4332018012	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.05581	-118.38242	Plan check for PV roof mounted system. System size: 3.8kW with 15 microinvertersa and 15 modules. Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49566	18041-30000-41593	8727-8731 W PICO BLVD	90035	5	132B169   922	4332018045	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.05464	-118.38217	Full plan check for power and energy for change of use and tenant improvement to convert an existing restaurant (A occupancy) to a Medical Office (B Occupancy). Existing 400A delta dist. board to feed (3) new panelboards. Total area: 5,068 sq.ft(B# 18016-30000-33189)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49567	12041-10000-02985	3625 S GRAND AVE	90007	9	118-5A203 223	5122023027	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.01785	-118.2778	Service upgrade and adding 2 elevators in an existing public storage highrise building, resupply existing cellphone users. Adding office area.  Plan check for power and T24. <Hi Rise Retrofit Buiding - Inspector to verify the conditions of approval for installing 120Minute unit equipment for emergency lights.>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49568	13041-10000-15613	6600 N TOPANGA CANYON BLVD # 1082D	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Expired	07/08/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	"INSTALL 1'- 2"" X 28' -0"" ILLUMINATED INDIVIDUAL CHANNEL LETTER MALL SIGN ""CALIFORNIA PIZZA KITCHEN"" TITLE 24 PLAN CHECK AND PERMIT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49569	15041-10000-10794	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	33.98489	-118.42552	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49570	13041-20000-35460	7315 W SUNSET BLVD	90046	4	147B181   598	5550017021	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.09816	-118.34938	PC FOR T24 ENERGY ONLY. TOTAL AREA 742 SQ FT. NEW LIGHTING MASSAGE PARLOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49571	14041-20000-06957	1150 S OLIVE ST	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.03962	-118.26181	T.I. to existing high rise building portion of 22nd floor.  Install and relocate light fixtures.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49572	18041-10000-01505	7055 N SOPHIA AVE	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.20003	-118.4871	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 15950 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49573	16041-10000-14133	1319 W 37TH PL	90007	8	117B197    79	5040010017	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.02009	-118.29799	PV2, NEW ROOF SOLAR MOUNTING SYSTEM USING CENTRAL INVERTERS IN A MULTIUNIT RESIDENTIAL. (12 MODULES, 1 INVERTER, 3.0KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49574	10041-10000-16258	6600 N TOPANGA CANYON BLVD #62	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to existing building.  Install general/emergency lightings.  Plan check for energy only.2 OF 2 (10042-10000-14702).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49575	11041-20000-25043	2250 N PARKSIDE AVE	90031	1	138A227   214	5211012020	R3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Apartment			11/22/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.07193	-118.2	T24 lighting plan check for a multi buliding complex.  Extent to work is to replace existing exterior lighting with lower wattage high efficacy fixtures.   This lighting if site lighting, carport lighting, and stair lighting.  No new poles or lighting controls to be installed.  Replace 247 lighting fixtures in total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49576	18041-20000-16787	8142 N SUNLAND BLVD	91352	6	189B173    43	2409002032	[Q]C2-1VL-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.2183	-118.36947	Plan check for energy only in existing space T.I. new lighting. Total area: 4719 sq ftB#18016-20000-14389	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49577	13041-10000-35862	947 S TIVERTON AVE 6F,7F	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			12/24/2013 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.06246	-118.44303	pc for power and energy. assisted-living TI EXIST APT UNITS ON ENITRE 6TH AND 7TH FLOORS.4TH AND 5TH FLOOR PC # 13041-10000-35642ADDITION OF GENERATORS AND PANELS  PC # 13041-10000-35626	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49578	15041-10000-40766	1810 S PANDORA AVE	90025	5	132B157   764	4317001005	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			12/03/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.05644	-118.42429	PLAN CHECK FOR POWER AND ENERGY. NEW 9-UNIT 4-STORY APARTMENT BUILDING OVER PARKING GARAGE. 600 AMP SERVICE. methane zone. fire alarm variance filed on 1/15/2014. Energy code is based on 2008 standard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49579	15041-10001-06557	14640 W VICTORY BLVD	91411	6	180B149   895	2241003007	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.18644	-118.45224	(((4/10/2015- CHANGES MADE TO APPROVED SET. CHANGED FIXTURE A TO 60 WATTS. ENERGY CALCULATIONS TO BE RE-VERIFIED. THIS IS A PLAN CHECK ONLY APPLICATION)))Energy plan check for a change of use from a retail to a daycare center. Total area is 6315-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49580	17041-10000-38743												Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49581	12041-10000-27504	9311 N LASAINE AVE	91325	12	198B129   206	2766017014	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM			Reviewed by Supervisor	12/05/2012 12:00:00 AM	ADDRESS	34.23998	-118.5129	NEW 6KW ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49582	19041-20000-13991	3032 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	12/21/2021 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49583	09041-20002-10547	100 S THE GROVE DR	90036	4	138B177   451	5512004908	OS-1XL-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM			PC Approved	09/27/2010 12:00:00 AM	ADDRESS	34.0746	-118.35615	Plan check only. Revision delta 16 to approved plans permit # 09041-20000-10547. Plan check to clarify and show area control/multilevel control for media room and main gallery. Media room and main gallery controls via lighting control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49584	10041-10000-14225	111 E UNIVERSAL HOLLYWOOD DR 25th floor	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	12/10/2010 12:00:00 AM	ADDRESS	34.13855	-118.36112	T24 and emergency lighting plan check for the 25 floor.  Fire life safety variance was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49585	15041-10000-32997	7501 W SUNSET BLVD	90046	4	147B177   986	5550010022	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Closed	09/08/2017 12:00:00 AM	ADDRESS	34.0982	-118.35302	PC for power only. Service upgrade to an existing commercial building. Service is now 800 amps. Installing 17 new panels with no load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49586	14041-20000-17513	8000 W SUNSET BLVD #330	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.09783	-118.36466	TI to (E) commercial office space in (E) lowrise commercial office building.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49587	15041-20000-41807	837 S HARVARD BLVD	90005	10	132B193   774	5093017019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Apartment			12/11/2015 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.05675	-118.30436	Full pc for a New 6 story, 65 unit 5 level apartment building over a 2 level subterranean garage. Total area is 50359 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49588	18041-10000-39126	355 S GRAND AVE 8TH FLOOR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM			PC Info Complete	10/12/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLANCHECK FOR T24 ENERGY.  INTERIOR TENANT IMPROVEMENT OF 8TH FLOOR OFFICE. 312 SQFT BUILDING PERMIT # 18016-10000-32371	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49589	14041-10000-16959	1017 N LAS PALMAS AVE	90038	4	144B185   896	5532026036	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.08943	-118.33642	PLAN CHECK FOR POWER AND LIGHTIN.  TOTAL AREA = 17,685 SQ. FT.PROVIDE TRANSFORMERS + PANELBOARDS, RUN REC MECH AND LTG BRANCH CKT WIRING TO NEW EQUIPMENT.  PROVIDE EM LTG INVERTER.FEE ESTIMATE ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49590	13041-10000-15825	6834 W HOLLYWOOD BLVD	90028	13	148-5A185 161	5548006015	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.10138	-118.33965	13041-10000-15825This is a four story building, second floor TI second floor, title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49591	18041-20000-41920	953 N SYCAMORE AVE	90038	4	144B181   641	5531015010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	Plan check for fire alarm devices connect to fire alarm system(under core and shell permit) new fire alarm devices: 103 and 1 Power Supply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49592	13041-20000-35594	16060 W VENTURA BLVD SUITE 113	91436	5	168B141   600	2283011023	C2-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	ADDRESS	34.1561	-118.48335	pc for t24 energy only. new lighitng existing retail space. pizza cafe TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49593	12041-20001-25405	12161 W SATICOY ST	91605	6	186B165   215	2307015006	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.20863	-118.39866	(((3/18/2014- CHANGES MADE TO APPROVED SET HOWEVER NO PERMIT IS REQUIRED.  THIS IS A PLAN CHECK ONLY.)))New rooftop pv system for an existing single family residence.   System is ungrounded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49594	16041-20001-10878	21627 W DEVONSHIRE ST	91311	12	204B105   216	2722009005	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Issued	09/02/2016 12:00:00 AM	ADDRESS	34.2574	-118.60127	PC FOR POWER ONLY. T.I FOR A COMMERCIAL RETAIL STORE. SCOPE INCLUDES NEW 400 A SERVICE CONSOLIDATION SUPPLIED BY 800 A GUTTER, NEW LIGHTS, RECEPTACLES, AND ONE NEW PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49595	19041-20000-08542	21550 W OXNARD ST ste 990-995	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Issued	03/11/2019 12:00:00 AM	ADDRESS	34.179	-118.60001	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indooe energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49596	17041-20000-26264	9581 W PICO BLVD	90035	5	132A167   214	4330025005	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.05535	-118.39769	ti to an existing two storycommercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps, plan check for energy and em lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49597	19041-20000-36518	9922 N POOLE AVE	91040	7	201B177    50	2542013045	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	02/27/2024 12:00:00 AM	ADDRESS	34.25066	-118.36164	Plan check for PV roof mounted system, PV system size: 11.36KW DC, 11.52KW AC with 32 PV Modules and 16 microinverters, 1 sub panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49598	18041-20002-35301	4532 N WESTCHESTER DR	91364	3	166-5A111  15	2174016034	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Issued	10/30/2018 12:00:00 AM	ADDRESS	34.15237	-118.58225	10-30-2018 Changes to an approved set of plans. Changes include reduction of PV System size, from 15.3kW AC CEC to 11.5KW AC CEC, 12.5KW DC. All Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49599	11041-10000-16739	11932 N MALLOT PL	91344	12	216B137   315	2609008016	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2011 12:00:00 AM			Corrections Issued	08/11/2011 12:00:00 AM	ADDRESS	34.28745	-118.49544	New 8.28 KW roof mounted PV system.  Applicant is using the standard plan.  Plan check is for power,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49600	18041-20000-41578	11924 N SUSAN DR	91344	12	216B137   341	2609006004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.2872	-118.49787	Plan check for PV roof mounted system, system size: 11.4KW DC with 38 PV Modules and 38 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49601	15041-10000-16750	5109 E ALHAMBRA AVE PV1	90032	14	138A233   233	5216025002	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2016.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	34.07178	-118.17479	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(10) KYOCERA 260 MODULES(1) ABB PVI-3.0 INVERTER.PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-10000-15268Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.  2.6 KW PV SYSTEM (10) MODULES The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49602	12041-10000-07309	3731 W WILSHIRE BLVD 2ND, 4TH,-10TH, 11TH	90010	10	132B193    28	5503029017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.06188	-118.30736	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR EXISTING OFFICE TI SPACE ON THE 2ND,  4TH, 10TH AND 11TH  FLR. PERMIT FOR NEW BRANCH CIRCUITS. LESS THAN 400A LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49603	10041-10000-20350	2155 W VENICE BLVD	90006	10	126B193   280	5074009010	[Q]C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM			Corrections Issued	10/13/2010 12:00:00 AM	ADDRESS	34.04374	-118.30443	Ti in an existing commercial building. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49604	18041-10000-19833	2484 E OLYMPIC BLVD	90021	14	121-5A219 158	5168002900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.0254	-118.22674	PC FOR NEW FIRE ALARM. SCOPE INCLUDES TWO  NEW PANEL AND 21 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49605	12041-20000-00829	5244 N LAUREL CANYON BLVD	91607	2	171B165   385	2348008098	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM	01/12/2012 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.16618	-118.39624	energy plan check retail store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49606	19041-30000-34758	6255 W SUNSET BLVD STE 1520	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Issued	09/03/2019 12:00:00 AM	ADDRESS	34.09815	-118.32564	TENANT IMPROVEMENT TO EXISTING OFFICE IN HIGH-RISE. P.C FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49607	19041-10000-01067	5838 N LANKERSHIM BLVD	91601	2	174B169   118	2338013040	[Q]C2-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.17684	-118.38162	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49608	18041-20000-33420	20611 W CHESTNUT CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.29272	-118.5837	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49609	15041-10000-35073	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	33.94286	-118.39982	FULL PC FOR AN ADDITION TO TERMINAL 7 IN LAX. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES ON LEVEL 4, CONNECTED LOAD >400AMPS. Pg E040 CONTAINS THE PANEL SCHEDULES FOR THE SCOPE OF WORK. PANELS WERE APPROVED UNDER A DIFFERENT APPLICATION. TOTAL SQ. FT. 20,000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49610	10041-20000-24751	15301 W VENTURA BLVD 3rd Fl	91403	5	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	04/20/2011 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check T-24 energy (general/emergency) lighting for remodel of existing tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49611	13041-20000-35541	716 S SPRING ST 101-119	90014	14	127-5A211 124	5144015042	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Info Complete	03/21/2014 12:00:00 AM	ADDRESS	34.04398	-118.25255	PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT. OCCUPANT LOAD EXCEEDS 100 OCCUPANTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49612	11041-10001-16563	4411 W SLAUSON AVE	90043	8	108B181   695	5008015044	[Q]C1.5-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.98904	-118.35222	Plan check revision to approved plans. Changes to feeder location supplying Verizon Panel A and T24 Energy for new lighting in equipment room. Feeder now located on 600A switchboard with a new submeter and new 50KVA transformer. Additional permit for 50KVA transformer and submeter panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49613	17041-10001-46202	10250 W SANTA MONICA BLVD # 1400	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"This is supplemental plan check only. Revision to approved plan to add patio heaters for  tenant/restaurant ""CRACK SHACK"" ste. 1400 in Westfield Century City. Permit is covered under master #17041-10000-46202"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49614	15041-20000-42580	8609 N LANGDON AVE	91343	6	192B145    13	2654018015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Expired	01/22/2018 12:00:00 AM	ADDRESS	34.22686	-118.46999	Plan check for PV roof monted system. System size: 5.0kWac with 23 modules and 1 inverter(5.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49615	17041-10000-30778	10447 N MONTGOMERY AVE	91344	12	207B141   798	2668019030	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.26062	-118.48173	PV1, NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.09KWdc / 6.0KWac.(21)MODULES-SOLARWORLD SW 290 MONO BLACK (1)INVERTER-SMA SB-6000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49616	11041-20000-08579	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			Corrections Issued	04/28/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	Install indoor electrical sign.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49617	16041-10000-36631	600 W WILSHIRE BLVD 4TH FLOOR	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.04796	-118.25622	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 4TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE/CONFERENCE SPACES. TOTAL AFFECTED AREA IS 15195 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49618	18041-10000-04636	2807 W SUNSET BLVD	90026	13	141A205    69	5402001019	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.08197	-118.27165	PC for power and energy for office/resturant shell building. Installing new 2000A 120/208 service.Scope includes new sub-panels, lights, receptacles amd equipment for common areas. B# 18016-10000-04046. Total 18226sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49619	11041-20000-09935	18000 W DEVONSHIRE ST	91330	12	204B125   310	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.25313	-118.52557	PLAN CHECK T24 ENERGY FOR LIGHTING/EMERGENCY TENANT IMPROVEMENT ON 1ST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49620	19041-10000-17640	811 W WILSHIRE BLVD Suite 450	90017	14	130-5A209 205	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.04973	-118.2584	TENANT IMPROVEMENT IN EXISTING OFFICE SUITES: 401, 402, 403, 404, 405 & 406.INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-13311 was issued for Suite # 450 (Subject to field Inspection)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49621	17041-10000-05173	1020 W VENICE BLVD	90291	11	108B149   549	4237017001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Issued	05/09/2017 12:00:00 AM	PIN	33.99366681	-118.45280358	New service rated at 600A 3ph 120/240V for a new restaurant.Scope includes power and energy. Total affected area 13697 sq.ft. indoor and outdoor.Bld app# 15010-10000-03210	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49622	14041-10001-03876	1319 S OGDEN DR	90019	10	129B177   249	5086015009	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.05248	-118.36406	Expedited RSES plan check per applicant request.{{PV1, Install 45 kW DC roof-mounted solar array on a two-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 5000A-US. (18) Modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49623	18041-10000-43586	11150 W SANTA MONICA BLVD 10Th Flr	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI TO EXISTING PUBLIC RESTROOMS ON THE 10TH FLOOR.  T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49624	16041-10001-37796	400-562 S PIER A PV	90744	15	024B205    48	7440019907	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	12/09/2016 12:00:00 AM	PIN	33.75773794	-118.27050253	EXPEDITED PER APPLICANT REQUEST************************************************************************************.PC FOR ROOF MOUNTED PV.  FEED IN TARRIF (FIT) PROJECT . SYSTEM SIZE 1143KW.DC  913KW.AC SCOPE INCLUDES TOTAL OF 3362 MOUDULES AND 11 INVERTERS (83KVA).WITH NEW DEDICATED SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49625	18041-10000-43005	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Issued	11/19/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR POWER ONLY. TEMPORARY POWER FOR A CONSTRUCTION SITE. SCOPE INCLUDES INSTALLING A NEW 800AMP - 480/277 DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49626	15041-20000-43998	16654 W WYANDOTTE ST	91406	6	186B137   344	2226016009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.20282	-118.49652	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.7 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49627	16041-10000-00892	12700 W MILLENNIUM # 52	90094	11	102B161  1280	4211037036	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.5KW INTERCONNECTED WITH MSP.ADDITIONAL CIRCUIT FOR AC MODULE SUPERVISOR.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49628	11041-10001-20674	1034-1042 E ELKGROVE AVE BLDG 17	90291	11	111B145   518	4243001035	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			04/16/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.00166	-118.45883	LINCOLN PLACE APARTMENT PROJECT ((((((((((((((< Addition of 3 EV. 4-16-14))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49629	14041-10002-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Closed	05/20/2020 12:00:00 AM	ADDRESS	33.95637	-118.3838	"Changes to an approved set of plans. All changes are clouded under Delta-5. Changes include removing distribution boards ""MSA1"" and ""MSA2"", adding new distribution boards, adding new panels for each unit, adding house panels, revising floor plans, and revising single line diagram."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49630	16041-20000-17873	3833 N WINFORD DR	91356	3	162B121    39	2177047022	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.14068	-118.55007	$0 PERMIT FEE PER SENATE BILL SB 1222. PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 21KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49631	15041-10000-41001	416 W 8TH ST	90014	14	127-5A209  58	5144018030	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Public Safety Only			12/07/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04471	-118.25646	NEW FIRE WARNING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49632	10041-10000-04701	625 E ANAHEIM ST	90744	15	030B209     8	7423024016	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	08/27/2010 12:00:00 AM	ADDRESS	33.78052	-118.25524	INSTALLING A NEW 600A SECTION IN AN EXISTING MCC TO SUPPLY A NEW MCC-1 BOARD FOR NEW PUMPS, AGITATORS AND SKIMMERS AT A DEWATERING PLANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49633	17041-10000-08944	4622 W AMBROSE AVE	90027	4	150B197   223	5590005037	R3-1XL	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.10981	-118.29107	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 4400 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49634	13041-20000-12367	12930 W VENTURA BLVD 226C	91604	5	165B161  1027	2385026024	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			05/13/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.14513	-118.41481	FULL PLAN CHECK FOR CHANGE OF USE FROM CHIROPRACTOR TO DENTIST OFFICE. 2455 SQRFT. EXISTING BUILDING. NOT A STATE LICENSED BUILDING,  PER ENGINEER.  NOT CHECKED FOR OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49635	14041-20000-03102	1631 W 259TH PL	90710	15	033B193   216	7411003028	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	33.78761	-118.30548	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE5.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49636	16041-10000-04485	11111 W SANTA MONICA BLVD 400	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Info Complete	02/09/2016 12:00:00 AM	ADDRESS	34.04771	-118.44481	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 4TH FLOOR. SCOPE INCLUDETI ADDING NEW LIGHTS, RECEPTACLES, AND REMOVING/ADDING PARTITIONS. TOTAL AFFECTED AREA IS  5325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49637	10041-10000-23918	6090 W PICO BLVD	90035	10	129B173   245	5068002001	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.05263	-118.37368	ROOF MOUNTED 6.891KW SOLAR ARRAY INSTALLATION.  Existing permit 10041-10000-20417.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49638	15041-10000-22891	8065 N WEBB AVE SUITE A	91605	6	189B169    98	2310008003	C2-1VL, M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.21748	-118.38966	FULL PC,  CHANGE OF USE TO A MEDICAL BUILDING. CHANGE OF USE FROM RETAIL TO MEDICAL SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUITS.  PC FOR POWER AND ENERGY. 3 NEW PANELS. TOTAL SQ. FT. 1505.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49639	18041-10000-30245	2500 S HOOPER AVE	90011	9	118-5A211 416	5118009014	[Q]C1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.01717	-118.24945	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49640	16041-10000-24035	10990 W WILSHIRE BLVD 1040	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.0577	-118.44711	Plan check for Title 24 for 2629 sqft. Office TI..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49641	19041-20001-36135	8532 N VINEVALLEY DR	91352	2	192B177    56	2404030010	RA-1, RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.22566	-118.35538	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGE TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO SINGLE LINE ONLY, DISPLAYING EXISTING 175A MAIN CIRCUIT BREAKER ON EXISTING SUBPANEL AND REMOVING AIC RATING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49642	16041-10000-03858	4126 N TOLAND WAY	90065	1	154-5A219  10	5472004015	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.11987	-118.22551	PV1, rooftop solar installation 3 kW AC system(14) CS6P-260P      (14) ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49643	18041-20002-36457	11419 N MONTALCINO WAY	91326	12	213B109   412	2701068023	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.27907	-118.58671	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET. CHANGES TO SINGLE LINE DIAGRAM. CONVERSION FROM PARTIAL TO FULL HOUSE BACKUP AND MINOR CONDUCTOR SIZE INCREASE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49644	11041-20000-02628	16200 W STAGG ST	91406	6	189B137    71	2205004029	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	02/10/2011 12:00:00 AM		Issued	02/10/2011 12:00:00 AM	ADDRESS	34.213	-118.48645	Install new general lighting for a warehouse.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49645	17041-20001-34183	14319 W JOY DR	91331	6	198B153  1029	2644027241	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24167	-118.44518	Revision to approved set.  Change to higher power module type and inverter rating increased to 3.8 kW AC. (((Plan check for solar pv system, roof-mounted array on SFD.3kW ungrounded system. (12) 305W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49646	13041-20001-28379	734 N LA CIENEGA BLVD	90069	5	141B173   308	5528001064	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			PC Approved	07/21/2014 12:00:00 AM	ADDRESS	34.08459	-118.37633	Change from previously approved plans.  Changes include remove lighting control panels.  Plan check for power and energy.Note: Permit is under the original application.*****Previous Description*****Addition to (E) 1-story retail/gallery w/ mezzanine, addition of 2nd floor offices.  New main switchboard and other power distribution equipment.  Plan check for power and energy. Changes: includes addition of bugeyes in gallery 3, bugeyes on same ckt as general ltg.Plan check fees adjusted to meet applicant's check amount.  Full submittal fees to be recalculated at 34 branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49647	17041-10000-14945	9510 N TOPANGA CANYON BLVD	91311	12	201B101   596	2746018008	(Q)MR1-1, [T][Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24357	-118.60646	PC for energy only, Removing HID fixtures and replacing them with new LED. Area: 11,850 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49648	13041-10000-20233	1097 S GLENDON AVE	90024	5	132B153   132	4363020001	C4-2, D, O	West Los Angeles				2652.02	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	PIN	34.06099027	-118.44468397	REMODELING EXISTING RESTAURANTIBOILING CRABPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49649	11041-20000-05178	10780 W SANTA MONICA BLVD # 210	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	03/16/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.0504	-118.43387	energy plan check suite # 210	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49650	15041-10000-32909	8020 W BEVERLY BLVD 1st fl	90048	5	138B177   470	5511003023	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.07593	-118.36453	T-24 to an existing restaurant, scope: restroom remodel adding new fixtures and new addition of walk-in storage area. Total area: 377 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49651	16041-10000-31606	920 S CROCKER ST #107	90021	14	124-5A211 152	5132002059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Issued	09/07/2016 12:00:00 AM	ADDRESS	34.03569	-118.24958	PC FOR T24 ENERGY ONLY. NEW LIGHITNG FOR RETAIL SPACE. UNIT 107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49652	19041-20000-04190	1111 N LINDA FLORA DR	90049	5	144B145   168	4368026016	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2019 12:00:00 AM			PC Info Complete	09/04/2019 12:00:00 AM	ADDRESS	34.09008	-118.46522	Alteration to fire-damaged SFD.  New 600A 240/120V 1ph-3w service.  Plan check only for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49653	17041-20000-12077	20155 W JUBILEE WAY	91326	12	213B113   414	2701087040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.28261	-118.57342	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD ACM PLAN. SYSTEM SIZE: 4.8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49654	13041-20000-35599	9950 N WOODWARD AVE	91040	7	201B193   162	2562001010	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM			Reviewed by Supervisor	01/03/2014 12:00:00 AM	ADDRESS	34.24998	-118.3064	((((((((((((((((((((DUPLICATE APPLICATION))))))))))))))))))))))))))))))))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING TRANSFORMED INVERTER, SYSTME IS GROUND MOUNTED. APPLICATION INCLUDES MAIN PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49655	19041-10000-47610	11731 N VANPORT AVE	91342	7	213B165   181	2531026080	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.28311	-118.39576	NEW ROOF MOUNTED 6.4 KW (DC) PV SYSTEM WITH 21 PV MODULES (305W), 21 OPTIMIZERS,  AND 1 @ 5KW INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49656	19041-10000-32792	830 E JEFFERSON BLVD	90011	9	117A207   268	5121003008	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM			Corrections Issued	10/22/2019 12:00:00 AM	ADDRESS	34.01404	-118.2625	FULL PLAN CHECK FOR A NEW 2 STORY WAREHOUSE WITH ACCESSORY OFFICE ON SECOND FLOOR AND ROOF TOP DECK. SCOPE INCLUDES NEW 1200A 277/480 3PH 4W SERVICE. TOTAL AFFECTED AREA IS 23770 SQ.FTB#19010-20000-03116	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49657	19041-10000-19576	20800 W LASSEN ST	91311	12	201B109   117	2748004058	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			Reviewed by Supervisor	06/20/2019 12:00:00 AM	ADDRESS	34.24984	-118.58655	(Assign to Edwin or John per Mr. Nabil request)PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 1075 MODULES (Q-PEAK 390), 546 OPTIMIZERS (P850), 3 INVERTERS ( SE 99.9K), AND 1 INVERTERS ( SE 33.3K). SYSTEM SIZE IS 333.0KWac AND 419.25KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49658	18041-10000-22747	591 N IRVING BLVD	90004	4	141B189   663	5523030021		Central				1924.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/29/2018 12:00:00 AM	ADDRESS	34.08149	-118.31884	Plan check for a PV1 5.2KW AC roof mounted system with (17) modules and (1) 5.2KW inverter interconneting through the main service panel with center-fed connection.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49659	15041-10000-37478	17851 W CHATSWORTH ST	91344	12	207B129   359	2712030032	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.26514	-118.52322	PC for energy only,  T-24 to a commercial bulding (retail store). Scope includes new lighting and receptacles. Total area : 2075 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49660	14041-20000-27029	6930 N BALBOA BLVD	91406	6	183B133   682	2225023031	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			10/01/2014 12:00:00 AM			Reviewed by Supervisor	11/14/2014 12:00:00 AM	ADDRESS	34.19655	-118.50091	plancheck for power and energy. 10 new homes one service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49661	17041-20000-44482	500-506 S SAN PEDRO ST	90013	14	127-5A213 248	5147025022	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.0439	-118.24387	Plan check for energy only. TI to existing retail market. New lighting (incl. emergency) - 1,230sqft. Building permit application #17016-10000-31836.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49662	18041-10000-01317	23391 W MULHOLLAND DR #A	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM			PC Info Complete	01/12/2018 12:00:00 AM	ADDRESS	34.15972	-118.63416	Plan check for title 24 only in existing space, restaurant. Total area: 1205 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49663	16041-20001-04020	5601 N DE SOTO AVE	91367	3	174B109   380	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM			PC Approved	03/15/2017 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plans lost - this application is plan check only for reapproval.  (((PC for T-24 only. PV info on the plan is not part of this scope of work. Total area 228,880 sq. ft. All electrical equipments are existing.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49664	16041-20001-41136	13965 W SYLVAN ST	91401	2	177B153   173	2239009008	RS-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.18451	-118.43776	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP. Derating main to 150A. 10.2kW (4.2+6) ungrounded system. (37) 327W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49665	19041-10000-29850	917-933 N NORTH MAIN ST	90012	1	133-5A215  35	5409008023	[Q]C2-2-RIO	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	34.06161	-118.23518	PC for energy only. Outdoor title 24. Adding new lighting to parking lots. Total sqft = 24040.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49666	15041-10000-12700	3315 S GRIFFITH AVE	90011	9	117A207   263	5120028016	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Refund in Progress	10/06/2015 12:00:00 AM	ADDRESS	34.01414	-118.26134	T24 ONLY.  REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXUTRES. TOTAL AREA 3590 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49667	12041-10000-27670	11755 W WILSHIRE BLVD	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM			PC Approved	03/07/2013 12:00:00 AM	PIN	34.04869377	-118.46238681	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS ON A TENANT IMPROVEMENT. PERMIT WAS PULLED UNDER A SEPARATE APPLICATION NUMBER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49668	14041-20000-26827	14115 W VENTURA BLVD	91423	4	165B153   394	2265020022	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.14974	-118.44044	Plan check for energy only. TI for existing Taco Bell restaurant. New lighting (incl. emergency) in dining area and building permiter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49669	13041-10000-18669	1999 S AVENUE OF THE STARS #3450	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.05886	-118.41642	PERMIT TO BE PULLED AT EPC COUNTER ONLY. PC FOR ENERGY ONLY. TI to existing office. less than 400A. hirise 1999 AVE OF THE STARSSUN AMERICA CENTER (no retrofit on file - check for variance for unit equipment). #3450.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49670	18041-10000-31743	5533 S EA WAY	90094	11	102B157   295	4211022015	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	09/15/2020 12:00:00 AM	ADDRESS	33.97374	-118.42896	PC FOR NEW FA IN (E) COMM. BUILDING 8 STORIES (2 SUBTERRANEAN) LOW RISE. SCOPE INCLUDES 243 DEVICES AND 7 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49671	14041-20000-30674	1000 W WILSHIRE BLVD # 600	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	34.05085	-118.26078	T.I. to existing high rise building on the 6th floor.  Install general/emergency lighting.  Plan check for energy  only.Note: permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49672	11041-10000-21443	10830 W PICO BLVD	90064	5	126B157   962	4255028012	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Expired	10/30/2013 12:00:00 AM	ADDRESS	34.04014	-118.42803	New elevator recall system and sprinkler monitor system.(INTERIOR  ARCHITECTURAL REMODEL; REPLACE (2) ELEVATOR SHAFTS; (1) FREIGHT AND (1) PASSENGER)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49673	15041-10000-05831	2405 W OCEAN VIEW TER	90731	15	009B197  1661	7465010***	[Q]RD1.5-1	Harbor			Y	2976.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	PIN	33.72205776	-118.288511	PV1.  Install 3.75 kW roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49674	13041-10000-07845	7236 W 90TH ST	90045	11	096B157   886	4119031016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	33.9561	-118.42013	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. USING MICROINVERTER M215 USING 14 PANELS STANDARD PLAN. TOTAL SYSTEM SIZE 3KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49675	11041-10000-14576	9301 N TAMPA AVE Space 17	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	08/08/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I.  Existing retail space.  National University will occupy the space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49676	19041-10000-36413	18761 W SHERMAN WAY	91335	3	183B121   111	2118025001	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	08/04/2022 12:00:00 AM		Permit Finaled	03/13/2023 12:00:00 AM	ADDRESS	34.20127	-118.54216	FULL PC FOR A NEW RESTAURANT, SCOPE OF WORK INCLUDES A NEW 1,000A  SERVICE (120/208 , 3P 4W), THAT FEEDS A 1,000A MAIN DISTRIBUTION BOARD THAT FEEDS VARIOUS SUBPANELS AND ROOFTOP EQUIPMENT. TOTAL AFFECTED AREA IS 49,568 SQFT. B# 19010-10000-03599	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49677	14041-10000-35273	899 S FRANCISCO ST	90017	14	129A207   155	5144023054	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.04731	-118.2643	Plan check for New 18 story Hotel: 350 gust rooms on 14 floors, and a 4 story podium with pool deck, meeting and ballrooms, Restaurant/retail space. 2 level of parking. Core and Shell. Service size: 1200A at 4160V. PERMIT FEES UNDER INSPECTION DUE TO PARTIAL PLAN CHECK DONE UNDER 14041-10002-35273	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49678	16041-10000-31822	630 W 6TH ST	90017	14	129A209   260	5144005***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.04916	-118.25624	PC FOR 600A PANEL INSTALL AND RECONNECT EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49679	14041-20000-33840	19706 W TRAMMELL LANE	91311	12	210B117   403	2701054021	RE20-1-H-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.27203	-118.56301	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 11.4kW. Ungrounded system. Using 400W power optimizers.38  295W pv modules across two strings (19+19).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49680	11041-20000-25097	3470 W WILSHIRE BLVD 1st & 2nd-floor	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04, 2124.10	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	ADDRESS	34.06152	-118.3001	Electrical plan check for modification on the 1st and 2nd floor.  Power, emergency, and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49681	19041-20000-44401	4813 N LOCKHAVEN AVE	90041	14	162A219   266	5683028005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.1369	-118.22406	$0 fee per AB1414PV1. INSTALL 14.175 KW DC PV SYSTEM WITH (45) MODULES(310W), (2) INVERTERS (SOLVIA 5.2 AND 7.6) AND (2) TESLA STORAGE BATTERIES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49682	10041-10000-08965	890 N ALMA REAL DR	90272	11	129B129   927	4411001018	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM			PC Approved	06/06/2011 12:00:00 AM	ADDRESS	34.04526	-118.52495	REPLACING EXISTING 400 AMP SERVICE AND FOUR NEW PANEL TO FEED EXSITNG LOAD. PANEL A1 AND THE CIRCUITS ARE NEW FEEDING GAS PUMP.  PLAN CHECK REQUESTED BY INSPECTOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49683	14041-10000-30879	11900 W OLYMPIC BLVD	90064	11	123B149   541	4259024003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.03252	-118.45186	Fire alarm system replacement for (E) commercial highrise building.  New FACP and 333 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49684	17041-20001-37663	12940 W ADDISON ST	91423	4	168B161    16	2358023021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM			PC Approved	10/30/2017 12:00:00 AM	ADDRESS	34.16107	-118.41537	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.Total system size: 15.2kW ungrounded.(2) 7.6kW SolarEdge inverters. (27) 280W pv modules.(26) 300W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49685	18041-10000-19046	700 S FLOWER ST #200	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLAN CHECK FOR T-24, INTERIOR IMPROVEMENTS FOR (E) RETAIL SPACE; TI WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2294	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49686	16041-20000-44070	2814 E CINCINNATI ST	90033	14	127-5A225  73	5178019026	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.04492	-118.20137	PV1.  Install 5.940 kW roof mounted grid tied microinverter PV system.  Microinverter standard plan.  (22) modules with 215W rated microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49687	19041-10000-52288	19233 W BERCLAIR LANE	91356	3	165B117    28	2177003013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Issued	12/18/2019 12:00:00 AM	ADDRESS	34.15202	-118.5531	PV1. NEW SOLAR SYSTEM ON EXISTING ON RESIDENTIAL ROOF TOP SYSTEM. TOTAL SYSTEM SIZE IS 11.34KWdc / 10.0KWac / 10.34KWac CEC.(36)MODULES-HANWHA Q-CELLS#.PEAK DUO BLK-G5(36) OPTIMIZERS-SOLAREDGE P400(1)INVERTER- SOLAREDGE SE10000H	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49688	14041-10001-02820	15801 W MOORPARK ST	91436	5	168B141   508	2261012016	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.15688	-118.47729	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON TRANSFORMERLESS INVERTERS WITH POWER OPTIMIZER ON A ONE-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) INVERTER: SOLAREDGE SE5000A-US(19) MODULES: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49689	16041-20000-34954	618 E 1ST ST 1st flt	90012	14			CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	ADDRESS	34.04855	-118.23637	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.  total square footage 1973.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49690	18041-10002-29964	19700 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	33.85221	-118.2903	CHANGES TO AN APPROVED SET OF PLANS NOTE CHANGES UNDER DELTA B. CHANGES INCLUDE THE ADDITTION OF THE CORRIDOR SPACE AND REVISION OF TIME CLOCK OPERATION. ________________Note: Plan check only. Permit is paid under PCIS#18041-10000-29964	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49691	14041-10002-35273	899 S FRANCISCO ST	90017	14	129A207   155	5144023054	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	34.04731	-118.2643	(((3/13/2015- PERMIT TO BE PULLED ON MASTER APPLICATION. THIS PLAN CHECK COVERS ALL THE CHANGES FROM THE ORIGINAL TO THE VERIFICATION APPOINTMENT))))Plan check for New 18 story Hotel: 350 gust rooms on 14 floors, and a 4 story podium with pool deck, meeting and ballrooms, Restaurant/retail space. 2 level of parking. Core and Shell. Service size: 1200A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49692	19041-20001-33091	6514 N ALDEA AVE	91406	6	180B133   345	2230022014	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.18905	-118.5078	EXPEDITED.PV1. INSTALL 12.285 KW DC SYSTEM SIZE WITH 39 MODULES  INCLUDING (2) INVERTERS (solivia 7.6 , 5.2 TL) AND (3) TESLA ENERGY STORAGE BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49693	15041-10000-06557	14640 W VICTORY BLVD	91411	6	180B149   895	2241003007	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.18644	-118.45224	Energy plan check for a change of use from a retail to a daycare center. Total area is 6315-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49694	17041-20000-10941	21800 W OXNARD ST suite 300	91367	3	177B105    81	2146006046	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.17898	-118.60253	ti to an existing commercial building.  adding new lightingnew controls to existing panels.  plan check for energy  and em lighitng.  total square footage 10692.  scope in the 3rd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49695	12041-10000-10297	17941 W CHATSWORTH ST	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.26503	-118.52485	Ti for a restuarant, one story, stand alone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49696	13041-10000-09123	10856 N VALJEAN AVE	91344	12	207B137    74	2680004006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.26776	-118.48641	INSTALLING PV1 SYSTEM ON THE ROOF. SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE IS 8.4 kW. USING A TOTAL OF 25 MODULES. MICRO-INVERTER STANDARD PLAN. ENPHASE M215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49697	18041-10001-08727	1717 N VINE ST 1-57	90028	13	148-5A187 368	5546004404	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.10222	-118.32701	Change to approved set by modifying the floor plan, calculation, and adding new devices. All changes under 1-7 only. <<<PLAN CHECK FOR A NEW FIRE ALARMS SYSTEM CONSISTING OF 8 FIRE ALARM PANELS AND 363 FIRE ALARM DEVICES.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49698	12041-20000-17206	13569 W VENTURA BLVD	91423	5	165B157   649	2360007030	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.14789	-118.42933	T-24 lighting plan check.  Permit is for installing new circuits in existing space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49699	17041-10000-36843	7315 N LANKERSHIM BLVD	91605	2	186B169   863	2317018038	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.20331	-118.38798	PC for T24 for TI for change of use from office/warehoues to sound production and gym area. Installing two new panels, relocating two panels and adding cirucuits and equipment. Total area is 3537sqft. Building 16016-10000-29391.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49700	16041-20000-30205	6319 N COLFAX AVE 2ND FL	91606	2	177B169    68	2334006040	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.18543	-118.38794	TI TO AN EXISTING COMMERCIAL 2 STORY  OFFICE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD LESS THAN 400 AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49701	17041-20000-17783	8641 N TAMPA AVE	91324	12	195B117   309	2783023007	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			Reviewed by Supervisor	06/07/2017 12:00:00 AM	ADDRESS	34.22758	-118.55375	Plan check for roof-mounted solar pv array with AC-coupled battery backup system.(1) 7.6kW ungrounded inverter. (26) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49702	16041-20000-11829	8941 W WONDERLAND PARK AVE	90046	4	153B169   287	5564015043	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Expired	06/19/2018 12:00:00 AM	ADDRESS	34.11485	-118.38945	Plan check for a PV1 ground-mounted PV system. System size is 7.7 kWac and consists of (24) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49703	17041-10000-02273	8960 N LURLINE AVE	91311	3	195B109    40	2780001042	MR2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.23342	-118.58405	PC for Tile 24 only. Remove HID exterior fixtures and replace with new LED fixtures. Area: 10,350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49704	19041-20000-51619	8647 W EDWIN DR	90046	4	156B169   309	5564002026	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.12155	-118.39053	PV1. INSTALL 10.08 KW DC PV SYSTEM WITH (28) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49705	16041-20000-37728	1109 S BOYLE AVE	90023	14	123A219   119	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.03155	-118.22031	remove existing hid fixtures and replace with new led outdoors.  plan check for energy 45700 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49706	14041-10000-10480	923 E 3RD ST STE #109	90012	14	129A217   170	5163006016	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	PIN	34.04631555	-118.23425262	PLAN CHECK FOR ENERGY ONLY FOR TI OF EXISTING RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49707	19041-20002-14893	4758 W BONVUE AVE	90027	4	153B197   302	5588017008	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM			PC Approved	08/21/2019 12:00:00 AM	ADDRESS	34.11445	-118.29464	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. CHANGES TO SINGLE LINE. ADDITION OF A EXISTING PANEL AND RELOCATION OF LOADS AND CHANGE TO FEEDER SIZES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49708	16041-10000-22627	7900 N SEPULVEDA BLVD	91405	6	189B145   465	2209032042	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.21386	-118.46596	PC FOR FA SYSTEM WITH 36 DEVICES AND MAIN CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49709	18041-20000-31412	10209 S CENTRAL AVE	90002	8	090B209   424	6049026004	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Info Complete	08/17/2018 12:00:00 AM	ADDRESS	33.9438	-118.25437	Plan check  for Title 24 Energy only T.I. of retail store spaces. Total area: 1029 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49710	17041-20000-29062	15105 W MISSION HILLS ROAD	91345	7	213B145    24	2664022013	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.28165	-118.4621	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49711	14041-20001-25709	15566 W RAYEN ST	91343	6	195B141   882	2654015017	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Apartment			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.23174	-118.47244	9.26.2017 - Plan check for modifications to approved set. Remove common area laundry, instead installing laundry circuits (combo units) in every dwelling unit. Update floor plans, panel schedules, and load calcs to reflect this change. Changes clouded delta 1.======PC FOR POWER AND ENERGY. NEW 31 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED. DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 NEC AND 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49712	14041-10000-05544	189 S THE GROVE DR SPACE F90B	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07125	-118.35662	4 NEW BRANCH CIRCUITS HAD ALREADY PULLED PER EXPRESS PERMIT 14041-90000-05180.{{New lighting system and electrical upgrades for existing restaurant, 975 sf.  Title 24 plan check for changes to lighting system.}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49713	11041-10000-26862	8401 N FALLBROOK AVE 2nd flr-East Wing	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM			Corrections Issued	12/16/2011 12:00:00 AM	ADDRESS	34.22253	-118.62558	T.I. to an existing diagnostics lab.  Connection of  powered  equipment, uninteruptable power source installation, branch circuitry, lighting circuit modification.  Less than 400A of  load change, per applicant.  PLAN CHECK for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49714	15041-10000-16642	12499 W OSPREY LANE #2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	33.97883	-118.41112	PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 2 SIZED 1.38KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19520.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49715	11041-20000-06677	17830 W SHERMAN WAY	91335	3	183B129   183	2121021024	R4-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Apartment			04/04/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Expired	07/15/2013 12:00:00 AM	ADDRESS	34.20085	-118.52145	PLAN CHECK FOR 39.5KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM  AND DERATE MAIN OVERCURRENT PROTECTION FROM 600A TO 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49716	17041-20000-28141	440 S CATALINA ST	90020	10	135B197   637	5502011020	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.06619	-118.29524	Plan check for roof-mounted solar system on apartment building.20kW ungrounded system (10+10). (77) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49717	19041-20001-46695	17953 W MEDLEY DR	91316	5	165B125   145	2184036027	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.14996	-118.52527	12-11-2019 Changes to an approved set of plan, Changes include remove performance meter. Changes has been clouded. Plan check only, permit covered under master application.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49718	18041-10000-24073	6316 N TOPANGA CANYON BLVD Unit #2140	91367	3	180B105    60	2146029020	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.18578	-118.60514	TENANT IMPROVEMENT IN A COMMERCIAL AREA. FIRST TIME TENANT, BEAUTY SALON. FULL PLAN CHECK FOR POWER AND ENERGY. BUILDING PERMIT #: 18016-10000-20543	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49719	13041-10004-35469	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	Supplementel application to reflect work under permit 18041-10000-00227(E18LA00031). Plan checker created application 18041-10000-00227(E18LA00031) as new  job but should have been created as supplemental therefore this application will be used as reference for the job with all fees paid under 18041-10000-00227(E18LA00031).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49720	13041-10000-09448	4051 S ALAMEDA ST	90058	9	115-5A215  65	5117021020	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM			Reviewed by Supervisor	04/22/2013 12:00:00 AM	ADDRESS	34.00871	-118.23969	Power and energy for new 115,973 sq ft industrial building.  New 2,000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49721	11041-10000-21231	1168 S BARRINGTON AVE	90049	11	129B145  1183	4265001039	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			10/04/2011 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.0499	-118.46096	78 UNITS APARTMENT BLDG, 6 STORY, 2.5 LEVELS PARKING. VARIANCE IS TO BE FILED TO SEPARATE THE  FIRE ALARM PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49722	15041-10000-15053	15350 W SHERMAN WAY SUITE 140	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			PC Info Complete	05/18/2015 12:00:00 AM	ADDRESS	34.20099	-118.46808	TI-24 TO AN (E) OFFICE BUILDING. ADDING NEW LED LIGHTING TO ENTIRE FLOOR. TOTAL SQ. FT. 3594. PC FOR ENERGY ONLY .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49723	15041-10000-01260	9740 N COZYCROFT AVE	91311	12	201B109   191	2748005037	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.24763	-118.58186	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3876 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49724	18041-10000-14997	701 E NEW DOCK ST	90731	15	021B209    16	7440020908	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	33.75567	-118.25325	INSATALL A SUB-PANEL FOR THE NEW OPTICAL CHARACTER RECOGNITION (OCR) PORTALS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49725	13041-10000-07200	1901 S AVENUE OF THE STARS 15TH FL	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.05949	-118.41705	RENOVATION OF LIGHTING IN OFFICES. WORK DONE ON 15TH FLOOR IN OFFICES. TOTAL AREA 1530 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49726	14041-10000-02065	6171 W CENTURY BLVD STE #250	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	33.9457	-118.39324	T24 PART 6 ENERGY FOR (E) OFFICE SPACE, NON HIGHRISE BUILDING.  ADDING (7) NEW FIXTURES FOR AN APPROX. 7970 SQ FT AREA. REMAINING FIXTURES ARE EXISTING, AND RELOCATED.  PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.NOTE: PERMIT FEE ALREADY CALCULATED UNDER INSPECTION FEE FOR 7 NEW FIXTURES, AND 8 RELOCATED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49727	18041-20000-01857	355 S GRAND AVE 1st Floor	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	Plan check for Title 24 only. Project site is the ground floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,260 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49728	19041-10000-37986	1990 S BUNDY DR 350	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.03419	-118.45559	ENERGY PC ONLY FOR TI TO (E) OFFICE SUITE TO RELOCATE AND ADD NON LOAD BEARING PARTITIONS AND NEW MILLWORK. AREA OF SCOPE 1,616SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49729	19041-20001-08652	4500 S FIGUEROA ST	90037	9	112-5A201 144	5018034031	C2-1VL	South Los Angeles	South Los Angeles	Voices		2321.20	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.00263	-118.2825	Plan check for Title  24 only in existing space Tire shop and retail space Tenant Improvement. Total are:652 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49730	16041-10004-16332	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	33.76597	-118.28407	resubmit due to loss set of plans. Permit is existing.(((((PV2 5.1 Mega watts roof-mounted system with 23,184 modules, and 64 inverters interconnecting through utility transformers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49731	15041-10000-06987	2117 S 8TH AVE	90018	10	126B189  1330	5060016004	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.03739	-118.32614	PV1.  Install 4.050 kW DC roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49732	17041-20000-18042	19400-19408 W LONDELIUS ST	91324	12	195B117   145	2783027015	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.22976	-118.55588	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49733	12041-10000-29011	1432 N BEACHWOOD DR	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/31/2012 12:00:00 AM	ADDRESS	34.09679	-118.32107	PLAN CHECK FOR TITLE 24 WITH EMERGENCY LIGHTS. SINGLE STORY COMMERCIAL USING TAILORED METHOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49734	18041-20000-07890	20647 W CHESTNUT CIR (#266)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29359	-118.58414	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49735	17041-10000-24845	808 N CYNTHIA AVE	90065	1	151-5A223  71	5471008003	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.11066	-118.21423	PC FOR PV SYSTEM SFD TOTAL SYSTEM SIZE 2.5KW AC USING ENPHASE M215 MICROINVERTER AND 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49736	15041-20000-43070	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Expired	04/10/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Fee is $0.00 due to 2012 CA State Senate Bill 1222.PV2. NEW SOLAR CARPORT/CANOPY SYSTEM. TOTAL SYSTEM SIZE IS 815.0kWac. TAPPING ON THE LINE SIDE FOR PV INTERCONNECTION TO MAIN FOR TWO SERVICES.  LIGHTING NOT INCLUDED ON PC.   (3150)MODULES-LG NEON LG365N2W-B3(23)INVERTERS-SOLECTRIA RENEWABLES. (4)PANELS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49737	19041-10000-03295	16573 W VENTURA BLVD	91436	5	168B137   287	2259018022	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.15802	-118.49433	FULL PLAN CHECK FOR A RESTAURANT T.I WITH A NEW 1200-AMP SWITCHBOARD; SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH NEW PANELS AND LIGHTING LOAD. TOTAL AREA CONSIST OF  5910 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49738	19041-10000-29783	8334 S COLEGIO DR	90045	11	096B157   336	4114033022	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	05/25/2020 12:00:00 AM	ADDRESS	33.96133	-118.4216	PLAN CHECK FOR NEW ESS(TESLA POWERWALL) TO EXISING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49739	13041-10000-25585	3954 S HOBART BLVD	90062	8	114B193    66	5036027006	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	34.01249	-118.30765	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 6 KW DC ON MICROINVERTER STANDARD PLAN IN A SINGLE-STORY HOME. LOAD CENTER WILL BE USED.(24) MODULES: TRINASOLAR TSM-250PA05.08(24) 215W  ENPHASE MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49740	19041-20000-51041	12445 W MOUNTAINGATE DR	90049	11	150B137     1	4490024009	[Q]A1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	03/13/2020 12:00:00 AM		Permit Finaled	02/09/2021 12:00:00 AM	ADDRESS	34.1074	-118.48784	Power and lighting for indoor and outdoor commercial spaces.  Plan check for energy. T24, total square footage = 8700 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49741	16041-10000-13788	5251 W IMPERIAL HWY	90045	11	087B173   142	4129038001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	33.93108	-118.37125	PC for energy only. Remove HiD fixtures and replace with new LED fixtures. Total sqft = 26864	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49742	16041-20000-07890	21600 W OXNARD ST Ste 260	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.179	-118.6002	Existing office remodel.  Plan check for energy.  821 sq. ft.  All existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49743	17041-20001-33371	757 S ALAMEDA ST PHASE I	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.0318	-118.23916	10/24/18changes to an approved set of plans.  changes noted delta 11.  changes to add inverter to back up gas room exhaust fan.  ((((PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE OF EXISTING TYPE IA COMMERCIAL BUILDING - CORE AND SHELL.  PHASE I OF CORE AND SHELL DISTRIBUTION BASIC POWER AND LIGHTING.   BUILDING PERMIT UNDER 17016-10000-20345.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49744	11041-10000-00853	6600 W SANTA MONICA BLVD stage10&11	90038	4	144B185   776	5532024013	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10, 1919.00	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	34.09051	-118.33342	New PV system for a commercial building. EPC is for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49745	19041-10000-53495	1138 S HOBART BLVD	90006	10	129B193   849	5080021005	R3-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.04972	-118.30509	(E-PLAN) PERMIT FEES ARE $0 DUE TO ASSEMBLY BILL 1414. CHANGES TO AN APPROVED SET. SCOPE OF WORK INCLUDES ADDITIONAL DISCONNECTS TO TESLA BATTERIES. PER APPLICATION #: 19041-10000-49334.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49746	13041-10000-22318	1950 S SAWTELLE BLVD 2ND FLOOR-3RD FLOOR	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.04129	-118.44377	TITLE-24 FOR 2ND & 3RD FLOOR RESTROOMS;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49747	18041-10000-42343	3229 W CASITAS AVE	90039	13	153B209   585	5436002027	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Issued	01/31/2019 12:00:00 AM	ADDRESS	34.11548	-118.25102	Energy plan check for a commercial production facility T.I. Scope includes new lighting and receptacles with a total area of 3950-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49748	14041-20000-32678	160 S JUNE ST	90004	4	138B185   379	5515002007	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.07199	-118.33462	11.24.2014 - changes to approved set (permit issued under permit #14041-20000-26488.Delta changes. Change roof layout and number of modules on each string. Total number of modules is the same.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49749	19041-20000-14889	640 E SANTA CLARA AVE	90291	11	108B145   780	4239029007	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			04/23/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM	ADDRESS	33.99304	-118.46514	600A 240/120V 1ph-3w service upgrade to (E) 11-unit apartment building.  Replacement of unit and house subpanels with reconnected branch circuit wiring.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49750	11041-20000-25060	17207 W WILLARD ST	91406	6	192B133   458	2204004029	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2011 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.21885	-118.50791	Photovoltaic system with modules on the garage, and inverters by service adjacent to main house as on the plans.  The service is being upgraded to 200 amperes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49751	19041-10000-25682	7000 W 3RD ST	90048	5	138B177   793	5511027028	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.07135	-118.36168	POWER PLAN CHECK TO INSTALL 2 MANUAL TRANSFER SWITCHES AND DISCONNECTS WITH TEMPORARY GENERATOR TERMINATION ON 2 SERVICE SWITCHBOARDS (MSA AND MSB). EXISTING SERVICE SIZE IS 1000A EACH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49752	17041-20000-30280	3616 S TROUSDALE PKWY	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.01983	-118.28534	Plan check for power only. Project site is an existing commercial building (USC). Project scope is the replacement of a medium-voltage transformer and indicated distribution equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49753	18041-10000-06389	8160 W MANNIX DR	90046	4	150A175   189	5556004019	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	08/10/2019 12:00:00 AM	ADDRESS	34.10593	-118.37	PC FOR NEW ESS INSTALLATION. SCOPE INCLUDES NEW TESLA POWERWALL2 WITH NEW SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49754	15041-20000-24445	614 W HELLMAN WAY 2nd Floor	90089	9	118-5A201   5	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	PIN	34.02015856	-118.28226229	TI to existing commercial building (housing for USC). Plan check for energy only. 2nd floor. Adding new lighting including emergency. Total sqft. 2,009.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49755	10041-20000-22655	4242 W BEVERLY BLVD	90004	4	138B193   505	5518004032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	04/20/2011 12:00:00 AM	ADDRESS	34.07613	-118.30148	T.I. for Western Dental building.  Service upgrade.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49756	19041-10000-10262	1801 E 41ST PL	90058	9	114A213   137	5116029059	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.00713	-118.24109	Remove HID fixture and replace with new LED fixture, T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49757	19041-10000-42194	5324 W HOLLYWOOD BLVD	90027	13	148-5A195 119	5544020020	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.10157	-118.30651	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49758	14041-10001-14929	12244 W HUSTON ST	91607	2	168B165   278	2356010003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/23/2014 12:00:00 AM	ADDRESS	34.15929	-118.40018	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFPRMERLESS INVERTER. WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49759	13041-20000-08212	351 N FAIRFAX AVE	90048	5	138B177   147	5527036014	C2-1VL	Central	Wilshire	Mid City West		1945.00, 2144.00	Electrical	Electrical	Commercial			04/01/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	PIN	34.07764206	-118.36177355	Remodel of an existing 4,250 sq ft restaurant.  Occupancy load is greater than 99 (Place of assembly).  Full Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49760	12041-10000-07062	10500 S AVALON BLVD	90002	8	090A207   178	6051028031	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM			PC Approved	04/30/2012 12:00:00 AM	PIN	33.94090658	-118.26482862	Change out (55) existing light fixtures and relocate a 200A subpanel.  Load is less than 400A.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit is under #12041-7000-02068	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49761	10041-20000-18872	4500 W WILSHIRE BLVD 3rd Floor	90010	10	132B185    45	5090014001	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.00	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	ADDRESS	34.06175	-118.32753	T.I. to existing building in the entire 3rd floor.  Install new general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49762	14041-10001-14746	331 1/2 E 1ST ST	90012	14	130-5A215 321	5161012012	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Closed	03/03/2017 12:00:00 AM	ADDRESS	34.04992	-118.23998	Supplemental change to an approved set. Adding: (4)XFormers, Voltage rating change on (48) Panels <200A, and Voltage rating change on (5) Panels 201-600A ****CHANGE OF USE FROM RESIDENTIAL TO HOTEL. ALL CIRCUITS AND PANELBOARDS ARE CONSIDERED NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49763	15041-20000-35739	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.21499	-118.4422	adding distribution equipment to an existing warehouse before full ti moves in. pc for new feeder and transformers. ti and t-24 on new package in future.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49764	15041-10000-16384	3716 S VETERAN AVE	90034	5	117B161   652	4252020033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			05/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.01728	-118.41368	FA variance has not been filedNEW APARTMENT BUILDING 600 AMP SERVICE 4 stories with 4 units.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49765	17041-10001-43650	2847 W LEEWARD AVE	90005	1	133-5A201 214	5077015011	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.05886	-118.28554	PLAN CHECK ONLY. RE-STAMP NEW SET ( APPLICANT  LOST ORIGINAL)PERMIT FEES TO BE PAID UNDER ORIGINAL SET. (Original scope):PC for methane detection system on building with six stories above grade and two stories below grade. Installing 17 new devices, methane detection panel and fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49766	14041-10000-14871	12674 W SANDHILL LANE # 1 - 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	33.97715	-118.4149	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49767	16041-20002-44563	1828 E CESAR E CHAVEZ AVE 600	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	34.05014	-118.21571	01-16-2019 Changes to an approved set of plans, change work descriptionto Tenant Improvement  to Medical Officew and Lasick Center(Non-OSHPD-3) Non essential standby power system is installed. Changes apply to delta 5 only Plan check only. Note: This facility is not an ambulatory surgical center: reatments and procedures performed here will, at no timerender patients incapable of self perservation. NFPA 99 does not apply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49768	15041-10000-18723	12476 W OSPREY LANE 1-3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	33.97888	-118.41041	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'A'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'A' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49769	16041-10000-14753	4912 S VAN NESS AVE	90062	8	111B189  1179	5015023013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	33.99853	-118.31697	PV 1 roof mounted solar system installation to a single family home. (1) Inverter: 5.0 kw, (15) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49770	12041-10000-29469	6725 W SUNSET BLVD Suite #390	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.09814	-118.33717	TI IN AN EXISTING COMMERCIAL AREA IN SUITE #309 ON THE 3RD FLOOR.  PLAN CHECK FOR T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49771	16041-10000-00365	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	PIN	33.92817449	-118.43220714	PLAN CHECK FOR POWER ONLY, HYPERION WATER TREATMENT PLANT.  ADDING NEW 300HP MOTOR TO  DISTRIBUTION BOARD LVS-116.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49772	12041-10002-19058	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Approved	02/14/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	T24 PC FOR EN. CHANGES TO LTG IN BATH/KITCH/ENTRYChange to lighting, receptacles, load for an existing restaurant.  Load is 132.7 Amps and Occupancy load is 56, per applicant.  PLAN CHECK ONLY for Energy,  with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49773	13041-20001-25438	26316 S ATHENA AVE	90710	15	033B193   674	7411024016	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	ADDRESS	33.78321	-118.30484	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.25KW. 29 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49774	14041-10001-00520	8301 N RESEDA BLVD	91324	12	192B125   654	2785018068	C2-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.22097	-118.53628	SUPPLEMENTAL PLANCHECK ONLY. CHANGES TO THE WIRING AND MULTIWIRE SWITCHING. INSTALLATION OF OVERRIDE IN THE BACK AND ADJUSTING OF THE LOCATION OF THE SWITCHES.Plan check for T24 only. Total area 748 sq ft. El Polo Loco store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49775	15041-20001-38371	3833 S DUNN DR 1-40	90232	5	120B165  1292	4207005008	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			05/21/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.02201	-118.39919	5/21/2019changes to an approved set of plans.  changes to elevator and EV chargers.  this is plan check only.  ((((PC FOR A NEW 40 UNITS APARTMENT BUILDING, 6-STORY, 2 LEVEL PARKING GARAGE. TOTAL AREA 24874 SQ INDOOR+ 3423.924 SQ FT OUTDOOR.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49776	15041-10000-27353	11859 S AVALON BLVD	90061	15	084B205   939	6083022002	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	33.92534	-118.26541	PV1 roof mounted solar, interconnect with main service panel, system size: 2.12 kW(8) modules: KYOCERA # KU2656ZPA(1) inverter: PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49777	18041-10000-14537	14040 W ARMINTA ST	91402	6	189B153   969	2212001009	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.21283	-118.44134	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49778	10041-20000-16329	14808-14812 W OXNARD ST BLDG A	91411	2	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.17924	-118.45552	"Plan check for power only. Remove existing serivce and Upgrading service to 2000A service feeding existing load. ""COMPLY WITH DEPARTMENT ORDER effective date10/27/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49779	14041-20001-26750	21300 W VICTORY BLVD floors 10-12	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.18813	-118.59618	CHANGES TO APPROVED SET OF PLANS. CHANGE IN FEEDER TO PANEL 10PC. NO CHANGE IN LOADING, CHANGE IN FEED. PC ONLY. PERMIT FEES ALREADY COVER INSTALL. CHANGES CLOUDED DELTA 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49780	12041-10000-06323	1500 W PALOS VERDES DR NORTH	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	33.77939	-118.30372	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49781	16041-20000-13032	17420 W DONMETZ ST	91344	12	210B129   176	2711012032	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.27433	-118.51382	PV1.  Install 8.96 kW roof-mounted PV system.  (2) 5.0 kW central inverters with (32) 280W modules.  320A rated service equipment.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49782	10041-10003-16673	6515 S NORMANDIE AVE 1-20	90047	8	105B193  1578	6015008017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM			PC Approved	01/10/2012 12:00:00 AM	ADDRESS	33.98012	-118.30055	Delta A revision to approved plans. Indicating service entrance conductors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49783	16041-10000-43138	1471 N FOREST KNOLL DR	90069	4	147B169   717	5559014009	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM			PC Approved	03/06/2017 12:00:00 AM	ADDRESS	34.09757	-118.3806	Plan check for power to (N) 2-story Single family dwelling w/ attached garage. New service rated at 800 Amps 208Y/120V 3pahse 4wire. Plan check only. Permit for electrical was pulled under Application #16010-30000-01341	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49784	19041-10000-29612	510 S BROADWAY ST level 2	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	09/01/2020 12:00:00 AM		Issued	09/01/2020 12:00:00 AM	PIN	34.04751876	-118.25072319	FULL PC FOR TENANT IMPROVEMENT OF FLOORS 2,4, AND 5 IN AN EXISING BLDG. THIS IS THE 2ND FLOOR OF THE SERIES. SERVICE SIZE IS 600A, 120/240,3PH,4W AND 400A,120/240,1PH, 3W. AREA OF SCOPE 5670SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49785	14041-20000-11076	7900 N BALBOA BLVD BLDG M	91406	6	189B133   403	2205006902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Issued	09/11/2014 12:00:00 AM	ADDRESS	34.21347	-118.50092	PC FOR NEW SERVICE. BUILDING M. NEW 800A. ALL LOADS FUTURE. THIS IS PLAN CHECK FOR SERVICE ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49786	13041-10000-32282	5506 N MORELLA AVE	91607	2	174B169  1086	2348005009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Expired	02/23/2016 12:00:00 AM	ADDRESS	34.17059	-118.38982	PV1, Install 4.5 kW DC roof-mounted solar array for a 2 story house , interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 18 modules Yingli YL250P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49787	11041-20000-08400	2239 S COLBY AVE	90064	11	123B153   292	4260015028	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM			PC Approved	04/26/2011 12:00:00 AM	ADDRESS	34.03487	-118.44421	energy plan check warehouse	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49788	19041-20000-25298	11300 W TUXFORD ST	91352	6	195B173   307	2408024015	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Issued	07/03/2019 12:00:00 AM	ADDRESS	34.23025	-118.37686	service upgrade 800 amp to an exsitng commercial building.  NO LOADS.  plan check for power only.  all loads to be on separate permit under TI.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49789	14041-20000-18880	9010 N RESEDA BLVD	91324	12	195B125   108	2769001022	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.23445	-118.53589	NEW RESTAURANT, PER OCCUPANT LOAD, PLACE OF ASSEMBLY. PLAN CHECK FOR POWER AND ENERGY. PER BUILDING SUBMITTAL, ENERGY COMPLIANCE ACCORDING TO 2013 EFFICIENCY STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49790	17041-20000-21275	5700 W WILSHIRE BLVD Ste 540-550	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.06218	-118.35303	TI to an (E) commercial highrise office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49791	12041-10000-27129	1435 S CRESTVIEW CT	90024	5	132B157    35	4327010014	R1-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.06181	-118.4247	ROOF MOUNTED PV1 SOLAR INSTALLATION 12.099KW. (PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49792	16041-20000-19926	8741 N PENFIELD AVE	91324	12	195B113   447	2782030017	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.22939	-118.56904	PV1.  Install 10.08 kW roof mounted PV system.  (36) modules with microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49793	16041-20000-35357	11916 W PICO BLVD	90064	11	123B149   970	4259039009	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			10/05/2016 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.02999	-118.44856	Plan check for power and energy. Project site is a new 5-story, 100-unit mixed use apartment and retail building over 2 levels of basement parking garage. Total lighting area = 78,288 sq. ft.Note: Building application has been created under 16010-10000-01632	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49794	15041-20000-20670	12055 W BURBANK BLVD	91607	2	174B165   742	2340028065	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.17231	-118.396	Plan check Title 24 only for Yeshiva Ketana of Los Angeles. Total indoor lighting area: 1,091 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49795	16041-10000-31320	10740 W WILSHIRE BLVD Ground FL	90024	5	132B153   223	4325001023	[Q]R5-3-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.06028	-118.43733	Plan check for Titel 24 only in existing ground floor public area high rise hotel building. Total area: 10,135 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49796	17041-10000-00690	5860 W JEFFERSON BLVD	90016	10	120B173  1729	4205027022	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.02504	-118.37633	PLAN CHECK FOR POWER AND ENERGY FOR T.I BUILDING 3000A SERVICE 277/480 3 PHASE 4 WIRE 2 STORY BUILDING TOTAL AREA: 49,550 SQ FT. B#16016-10000-26214Note: Title 24(49,550 SQ FT.) and 49 Branch Circuits to be paid as part of verification. Applicant has precut check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49797	18041-20002-00601	12144 W LA MAIDA ST	91607	2	168B165   426	2356008003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.15841	-118.39803	SUPPLEMENTAL TO CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REARANGEMENT OF STRINGS AND MODULE RELOCATION - NO NEW ADDED LOAD PV1. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.16 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49798	18041-10003-08932	9764 N NATICK AVE	91343	7	201B149   385	2650016004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM			PC Approved	07/10/2018 12:00:00 AM	ADDRESS	34.24767	-118.45286	EXPEDITE PV PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49799	13041-10001-26851	1207 S VERMONT AVE	90006	1	129B197   797	5078028004	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			11/26/2014 12:00:00 AM			PC Approved	11/26/2014 12:00:00 AM	ADDRESS	34.04886	-118.29184	"Revisions to approved set.  Additional lighting proposed for individual tenant units.  (((plan check for power and energy to an Rehabilitation of (E) 13-stories apartment building.  12 floors, 9 units per floor. No change of use. 39 (E) panels to be replaced; charges will be based off new panels (not ckts) . existing 3000A, 208/120v 3ph, 4wire service. Installing new 80kW 120/208V 3ph-Y emergency gen set per applicant, with (2) new EM panels ( ""EM"" and ""EMA""). existing smoke detectors. To replace existing electric heaters with heat pump.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49800	16041-20000-26693	17618 W NORDHOFF ST	91325	12	198B129   448	2768024026	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.23569	-118.51865	PV1.  Install 6 kW DC roof mounted PV system.  (20) modules.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49801	19041-20001-39389	20301 W FULLBRIGHT PL	91311	12	207B113    83	2707004014	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.26477	-118.57572	Change of module from LG 340W to LG 350W.  $0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414. (((PV1.  Install 10.54 kW DC / 9.5 kW AC roof mounted grid tied PV system.  (31) modules with microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49802	14041-10000-26862	412 N FAIRFAX AVE	90036	5	141B177  1435	5527030018	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.07866	-118.36128	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT, NO CHANGE IN OCCUPANCY. MR. PIZZA. 1240 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49803	15041-10000-29908	207 N VERMONT AVE	90004	13	138B197   601	5518033020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.07477	-118.29189	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (RETAIL STORE). SCOPE INCLUDES REPLACING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AREA IS 4400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49804	14041-20000-20105	800 N PASEO MIRAMAR	90272	11	129B117    28	4416022039	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.04968	-118.55753	$0 permit fee is due to Senate Bill SB-1222.  (((PV1.  29 KW SOLAR SINGLE FAMILY)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49805	13041-10000-25433	1875 S CENTURY PARK EAST #1240	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.06115	-118.41457	PC FOR ENERGY ONLY. TI TO (E) OFFICE #1240. HIRISE EMERGENCY lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49806	11041-20000-00103	21031 W VENTURA BLVD 4th, 8th,-10th floor	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	02/09/2011 12:00:00 AM	PIN	34.16717222	-118.59179488	T.I. to existing high rise building.  Install general lighting in men/women restrooms near elevator lobby.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49807	10041-10000-22903	19707 W RINALDI ST	91326	12	210B117   380	2701040039	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	ADDRESS	34.27502	-118.56306	TENANT IMPROVEMENT FOR  AN  EXISTING RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49808	09041-10001-03947	8487 W 3RD ST BLDG  D	90048	5	138B173   683	5511013021	(T)(Q)C2-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM			PC Approved	01/26/2010 12:00:00 AM	ADDRESS	34.07344	-118.37533	Revise the single line diagram to reflect the actual field conditions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49809	11041-20000-21226	3624 S ROSEWOOD AVE	90066	11	111B149   252	4245010006	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.00299	-118.44589	pv system micro invereter single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49810	15041-20000-09497	2226 N STRADELLA ROAD	90077	5	153B145   176	4377029005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM			Not Ready to Issue	05/19/2015 12:00:00 AM	ADDRESS	34.11332	-118.46236	THIS IS PLAN CHECK ONLY APPLICATION. ALL PERMIT FEES HAVE BEEN COLLECTED FROM THE BUILDING PERMITPlan check for a new single family home. Project scope is the installation of a new 1000-amp service,  (1) 1000-amp rated main switchboard, (7) 225-amp rated panel boards, (1) 150-amp rated panel board, associated loads, and multiple A/C units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49811	17041-20001-32207	12811 N WOODLEY AVE	91344	12	222B133   494	2609002025	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.30296	-118.49954	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.11.4kW ungrounded system. (45) 330W pv modules.Each module has a 400W power optimizer.Derating main breaker to 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49812	19041-10000-45460	433 S SPRING ST 8th floor	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM	ADDRESS	34.04822	-118.24907	REMOELING OF OFFICE SPACE IN EXISTING TENANT SPACEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49813	12041-20003-10791	3183 W WILSHIRE BLVD STE 195	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.06196	-118.29111	(((CHANGES TO APPROVED SET OF PLANS. ENERGY CHANGES. PLAN CHECK FOR ENERGY CHANGES ONLY. NO CHANGES TO POWER.)))))Change of use from retail to restaurant.  Install new panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49814	15041-10000-33958	9805 W BURGEN AVE	90034	5	123B165   418	4311002026	R1-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM			Corrections Issued	10/21/2015 12:00:00 AM	ADDRESS	34.03471	-118.39911	PV1. SOLAR ROOF MOUNTED SYSTEM, TOTAL SIZE 6KW. NEW LOAD PANEL WITH EXISTING LOADS.  (30) MODULES AND (1) INVERTER. (30) KYOCERA #KU2656ZPA(1) ABB #PV1-6000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49815	18041-20000-33347	507 3/4 E BOCCACCIO AVE	90291	11	108B149  1622	4237007013	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	33.98841	-118.45857	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,644 sq. ft.Note: Building permit has been issued under 17016-30000-09405	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49816	16041-20001-05391	4444 N LANKERSHIM BLVD #108	91602	4	165B173   162	2423005011	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	05/17/2016 12:00:00 AM	ADDRESS	34.15169	-118.36642	05-17-2016 Change to approved set of plan. Changes include manufacturer control system change from L C & D to Lutron lighting control system. {{{{{TI to (E) commercial retail space.  2116 sq. ft. plan check for energy only.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49817	13041-20000-26772	7038 N OWENSMOUTH AVE	91303	3	183B105   519	2138008005	P-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.19845	-118.60139	T24 FOR OFFICE SPACE. TOTAL 7500 SQRFT. SCOPE OF WORK ON FIRST AND SECOND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49818	16041-20000-14086	3921 N LAUREL CANYON BLVD	91604	2	162B165   437	2369013019	R1-1-RFA-RIO, R1-1VL-RFA-RIO, [Q]RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.14179	-118.39477	Plan check for energy only. CHANGE OF USE OF PORTION OF DORMITORY TO EDUCATIONAL OFFICES AND CLASSROOMS. First floor TI. New lighting (incl. emergency) and receptacles.5,510sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49819	18041-10000-01113	11601 W WILSHIRE BLVD #100	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC for T24 only for office TI for exisiting tenant. Installing two new panels, 75kVA transformers, lighting, receptacles and equipment. Total area is 4186 sqft. B# 18016-10000-00905.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49820	19041-20000-52232	1031 W WEST 34TH ST	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	02/11/2020 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.02488	-118.28874	Plan check for Title 24 Energy only. new lighting install. Total area; 933 sq ft. B#19010-10000-04779	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49821	10041-10000-11692	7821 N HAYVENHURST AVE	91406	6	189B137   119	2205009088	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			06/18/2010 12:00:00 AM	06/18/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.2129	-118.49261	Ti in an existing warehouse. Plan check for T24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49822	15041-20000-39775	5800 W SUNSET BLVD PHASE 1C	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENTS FOR TV STUDIOS AND ASSOCIATED SUPPORT SPACES..  PHASE 4 of 5 PHASE PROJECT FOR STAGE 6 AND BUILDINGS 16. STAGE 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49823	16041-10003-10777	11109 N SEPULVEDA BLVD Suite 102	91345	7	210B145   124	2664007011	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.27256	-118.46785	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 15 ON PLANS. ADDED RESTROOM AND LIGHTING FOR IT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49824	19041-20000-08817	20229 W JUBILEE WAY	91326	12	213B113   396	2701087032	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.28317	-118.57444	PV1.  Install 9.1 kW roof mounted grid tied PV system.  (26) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49825	14041-20004-17303	5800 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.09728	-118.31693	8/18/2016Plan check for changes to approved set.  Add series rating for LA panels. Add insulated ground conductor for flex conduit.  Revised various mechanical equipment. Changes clouded delta-14. =====6/11/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 2 and Delta 3. Changes include downsizing the EM generator to 800 kW from 1000 kW, the EM distribution board has been separated to have sections, 10 new lighting control panels, the addition of 2 new civil sump pumps, addition of fire smoke damper circuits, relocation of additional circuits and upsizing of water heater circuit breakers. *****Previous Work Description*****A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49826	15041-20000-40841	1664 W OAK GROVE DR	90041	14	159A225    59	5689031013	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Expired	01/23/2018 12:00:00 AM	ADDRESS	34.13099	-118.20345	PV1, roof mounted solar 6kW AC, interconnect with (E) 200A service.(27) hanhwa q cell Q PRO G4 260(1) SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49827	18041-10001-06917	10628 N HALBRENT AVE	91345	7	207B145   407	2649009002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	ADDRESS	34.26333	-118.46542	Supplemental PC for changes to approved set. Revising main panel from new 225A to existing 200A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49828	14041-20000-06036	4912 N PLACIDIA AVE	91601	4	168B177   221	2420011014	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.15989	-118.35593	PV1 ROOFTOP TRANFORMERLESS SYSTEM. USING COMBINER BOX. TOTAL SYSTEM SIZE 5.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49829	13041-10000-27206	2131 W COLORADO BLVD	90041	14	162A223    98	5671010003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.13937	-118.21279	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALL NEW FLUORESCENT FIXTURES. 2280 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49830	18041-10000-16142	10717 W WILSHIRE BLVD 1-90	90024	5	132B153   109	4360011037	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			05/02/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.06101	-118.43634	Energy plan check for an apartment outdoor lighting. Total area is 600-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49831	12041-10000-09013	712 S GRAND VIEW ST	90057	1	132A203    39	5141017003	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			Reviewed by Supervisor	06/08/2012 12:00:00 AM	ADDRESS	34.057	-118.27908	New service upgrade for the shell only , building has no tenants,  only the house panel , other panels are future load.  Load and calculation to be provide	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49832	15041-10000-10686	13155 W HARTSOOK ST	91423	4	171B157   686	2358001002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.16408	-118.41994	PV1 ROOF MOUNTED, ONE FLOOR RESIDENTUAL. SIZE OF INVERTER7.5. AND 24 MODULES.  TOTAL 7.85KW -DC.  SUBMITTAL PER APPLICANT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49833	17041-20001-01333	10244 N WOODLEY AVE	91343	12	204B141   390	2669007018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	34.25673	-118.48466	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49834	10041-10000-00958	3435 W WILSHIRE BLVD #141	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00, 2123.04	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Finaled	08/25/2010 12:00:00 AM	ADDRESS	34.06194	-118.29866	T.I. for a high rise building1st floor (Tully's Coffee).  New general/emergency lightings, and circuits.  Plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49835	19041-10000-43305	9843 N MASON AVE	91311	12	201B109   365	2748005056	(Q)CM-1LD, (Q)M1-1D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	03/10/2020 12:00:00 AM		Permit Finaled	11/09/2020 12:00:00 AM	ADDRESS	34.24903	-118.58076	FULL PC (FIRE TIME TENNANT), SCOPE OF WORK INCLUDES THREE NEW HOUSE PANELS ALL AT 100A BUS, CONNECTED TO AN EXISTING 600A  SWITCHBOARD WHICH IS BEING FED BY AN EXISTING 1200A SERVICE (120/208 3P,4W).  TOTAL AFFECTED AREA IS 2400 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49836	15041-10003-28666	3150 W WILSHIRE BLVD # 200	90010	10	132B197   112	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			PC Approved	09/27/2016 12:00:00 AM	ADDRESS	34.06163	-118.29086	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE USE OF EMERGENCY PANEL TO POWER LIGHTING IN THE TENANT SPACE. IT IS NOTED ALL LIGHTING IS PROVIDED BY EMERGENCY POWER. ALL HOME RUNS REMAIN THE SAME. PROVIDED TRANSFROMER TO POWER LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49837	18041-10001-04827	3825 S 2ND AVE	90008	10	117B189   734	5034017021	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.01734	-118.31947	PLANCHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF INVERTER TO OPPOSITE SIDE OF HOUSE WITH 2 NEW AC DISCONNECTS LOCATED AT NEW INVERTER LOCATION, AND MAIN PANEL. ORIGINAL DRAWING REFLECT CHANGESPC FOR ROOF MOUNTED PV FOR SFD. SYSTEM SIZE 11.8KWDC/ 11.4KWACSCOPE INCLUDES 40 MODULES WITH OPTIMIZERS AND CENTAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49838	18041-20000-16781	6880 N TROOST AVE	91605	2	183B169   415	2320009005	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	05/04/2020 12:00:00 AM	ADDRESS	34.19595	-118.38628	New 3-story self-storage building (BLDG A) and accessory single story storage building (BLDG B). One 600A 480Y/277V service feeding 2 separate buildings.B#17010-10000-03291(3 Story Building(BLDG A)), B# 17010-10000-03321(A Single Story building(BLDG B))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49839	14041-10000-15008	2844 E 2ND ST	90033	14	126A225   188	5180022900	OS-1XL	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	34.03905	-118.20448	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MENS AND WOMENS BATHROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49840	15041-10000-24484	9410 N BALCOM AVE	91325	12	198B129   105	2766002027	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.24153	-118.52147	Permit fee is 0.00 due to Senate bill 1222PV1 INSTALL 13.6 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(59) MODULES:  REC SOLAR REC275TP(2) INVERTERS: SOLAREDGE SE6000 AND SE 7600A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49841	18041-20001-04532	6800 S AVALON BLVD	90003	9	102B205   234	6007019019	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Closed	10/30/2020 12:00:00 AM	ADDRESS	33.97824	-118.26497	4/19/18changes to an approved set of plans.  changes noted delta 1.  changes to add new transformers and associated panels with no loads.  change feeder type from CU to AL.  ((((2) new services 1200 amp each serving an existing commercial building.  plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49842	19041-10000-14087	6340 N LANKERSHIM BLVD	91606	2	180B169  1236	2335027013	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Issued	04/17/2019 12:00:00 AM	ADDRESS	34.18612	-118.38721	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49843	17041-10000-12197	2228 E 4TH ST	90033	14	126A223    42	5183017007	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.04113	-118.21337	PC for energy only, Indoor/Outdoor Title-24. Remove HID fixtures and replace with new LED. Area: 19,250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49844	16041-20000-21765	17725 W LEMARSH ST	91325	12	204B129   232	2734001015	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	07/30/2016 12:00:00 AM	ADDRESS	34.25599	-118.52076	PV1ADDITION TO EXISTING SYSTEM.  ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49845	10041-10000-19577	145 S SPRING ST 7th Floor	90012	14	130-5A213  30	5149001003	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/01/2010 12:00:00 AM			PC Approved	10/01/2010 12:00:00 AM	ADDRESS	34.05196	-118.24563	TI IN AN EXISTING OFFICE AREA ON THE 7TH FLOOR (LA TIMES).   PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49846	16041-10000-13737	2760 N HOLLYRIDGE DR	90068	4	154-5A191 220	5580016008	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.11768	-118.31844	PV1, NEW ROOF SOLAR MOUNTED SYSTEM USING 10 AC MODULES. TOTAL SYSTEM SIZE 3.27KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49847	17041-10000-23613	3361 N ANDRITA ST LOT 6	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 6 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05788	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49848	19041-10000-03810	16860 W DEVONSHIRE ST	91344	12	204B133   221	2685002041	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	PIN	34.2565482	-118.49956743	T-24 ENERGY ONLY PC FOR A CHANGE OF USE FROM RETAIL TO RESTAURANT DINING AREA. SCOPE INCLUDES NEW CIRCUITS, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 3080 SQ.FT B#18016-20000-26533	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49849	13041-10000-24267	4605 W DON MIGUEL DR	90008	8	114B177   417	5028019024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Expired	10/01/2015 12:00:00 AM	ADDRESS	34.00531	-118.35657	THE PCIS# IS ASSOCIATED WITH BOTH PLAN CHECK AND PERMIT.PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 8.82KW DC ON CENTRIAL INVERTER STANDARD PLAN (10KW LIMIT), 1 STORY-HOUSE. 36 MODULES:TRINA TSM-245PA05.181 COMBINER BOX: STG-CBRH-6-A 1 INVERTER: FRONIUS IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49850	17041-10000-35423	330 W 58TH ST	90037	9	108B201  1300	5101040009	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Issued	01/08/2018 12:00:00 AM	ADDRESS	33.98958	-118.27974	**zero dollar permit fee per California Senate Bill 1222PV2 84KW AC  roof mounted system with (324) module, (3) inverter, (3) transformer, and (3) sub panels.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49851	16041-20001-37022	1500 N EL CENTRO AVE 1st floor	90028	13	148-5A189 331	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.09917	-118.32359	SUPPLEMENTAL PLANCHECK FOR T24 ENERGY FOR ADDITIONAL LOBBY AND CORRIDOR.  1131 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49852	14041-20000-15473	7741 N BLUEBELL AVE	91605	2	189B161  1003	2305032016	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.2112	-118.41172	New roof mounted PV sytem with optimizers and transformerless inverter.  Total system size 10.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49853	16041-10000-21421	11111 W SANTA MONICA BLVD 14TH-15TH	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM			PC Approved	06/17/2016 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC FOR ENERGY ONLY, TI TO THE 14TH AND 15TH FLOOR OF A HIGH RISE OFFICE BUILDING WITH NEW CONVIENCE STAIR BETWEEN, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 6736.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49854	19041-10000-20208	3636 S BRONSON AVE	90018	10	120B185  1362	5044002011	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2342.00	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM			Reviewed by Supervisor	06/13/2019 12:00:00 AM	ADDRESS	34.02198	-118.33376	NEW 800KW, 277/480V, 3PH-4W, 1,200A GENERATOR. PENDING DWP POWER RE-CONNECTION TO AN EXISTING BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49855	14041-10000-13904	21717 W NORDHOFF ST	91311	11	150B133    42	4491005012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM			Corrections Issued	05/23/2014 12:00:00 AM	ADDRESS	34.23562	-118.60243	Permit to be pulled at EPC counter only. Plan check for energy only. Non-hazardous per applicant. Less than 400A and emergency lighting installed in 2 story building. BLDG#14016-10-09973: INTERIOR TENANT IMPROVEMENT FOR NEW WHOLESALE BAKERY APPROX 1600 SQ WITH APPROX 598 SQ OF WHOLESALE BAKERY STORAGE AND APPROX 495 SQ OF NEW COLD STORAGE AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49856	16041-30000-38094	1601 E OLYMPIC BLVD #203	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.02923	-118.24056	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49857	14041-10000-01836	12516 N NEDRA DR	91344	12	219B133   328	2609021025	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	06/11/2014 12:00:00 AM	ADDRESS	34.29771	-118.49924	PV1 7.31KWdc. 240V. microinverter. STD. 1story. Roofmount. [(34) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(34)modules: {solarworld SunModule SW-250 mono }]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49858	18041-10000-24778	1363 W COLTON ST	90026	1	135A209   208	5160011006	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			07/03/2018 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.06386	-118.25842	NEW 47 UNIT, 7 LEVEL APARTMENT BUILDING. SCOPE INCLUDES A 1600-AMP 3-PHASE 120/208V SERVICEWITH (13) TYPICAL UNIT. BUILDING PERMIT: 18010-10000-01729	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49859	12041-10000-02304	13535 W VENTURA BLVD C	91423	4	165B157   672	2360007038	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.14768	-118.42818	PLAN CHECK T24 ENERGY FOR TENANT IMPROVEMENT IN UNIT #C.  NEW SHOWER ROOM IN EXISTING DANCE STUDIO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49860	15041-10000-11691	1500 S EDRIS DR	90035	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.05223	-118.3974	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49861	10041-10000-06284	3764 W WILSHIRE BLVD	90010	10	132B193    68	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	06/03/2010 12:00:00 AM	ADDRESS	34.06148	-118.30835	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY)  LIGHTING FOR EXISTING AT&T TI IN HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49862	19041-10000-18518	111 W 9TH ST 1st Flr	90015	14	127-5A209 248	5144016051	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.04191	-118.25516	Energy plan check for a restaurant T.I  Scope includes new lighting only with a total lighting area of 575-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49863	13041-20001-25180	17631 W VANOWEN ST	91406	6	183B129  1030	2229001017	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.19401	-118.51769	CHANGES MADE TO APPROVED SET. INCLUDES REFERENCE SET. TAPPING OFF OF 1600A BUS TO A NEW 800A SECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49864	14041-20000-34316	4626 N ATOLL AVE	91423	4	168B157   683	2360024038	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.15481	-118.42019	PV1. CENTRAL/STRING INVERTER STANDARD PLAN. SYSTEM SIZE 7.2 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49865	19041-10000-43207	20065 W RINALDI ST Bldg A4-#170	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	04/27/2020 12:00:00 AM		Permit Finaled	10/25/2020 12:00:00 AM	ADDRESS	34.27548	-118.57184	First Time Tenant, Plan Check for Power & Energy. Installing Panels, 75KVA transformer & Lights in Bldg #A4, Suite#170.Core & Shell Electrical Permit: 17041-10000-04616(((Bldg Permit# 16010-10000-06137)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49866	12041-10000-19970	11620 W WILSHIRE BLVD # 445	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM			Reviewed by Supervisor	12/27/2012 12:00:00 AM	ADDRESS	34.05021	-118.45963	CHANGE OF USE OF SUITE #445 FROM EXISTING OFFICE TO MEDICAL DENTAL OFFICE (869 SQ FT): Full plan check for Power and Energy.  NOT CHECKED FOR OSPHD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49867	16041-20000-39497	13146 W KUEN PL	91401	4	171B157   128	2345021018	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	PIN	34.16789002	-118.41991756	Plan check for installation of solar PV system, roof-mounted on SFD. Interconnect with a 400A MSP.10kW ungrounded system. (28) 340W pv modules. Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49868	16041-20007-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			05/23/2019 12:00:00 AM			PC Approved	05/23/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	5/23/2019changes to an approved set of plans.  changes to revise the lighting schedule and update energy calculations.  this is plan check only.  ((((05/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 14. Changes have been made to indicated feeder sizes, lengths, and voltage drops.))))*****Previous Work Description*****SUPPLEMENTAL PLAN CHECK ONLYCHANGES TO AN APPROVED PLAN SET. CHANGES TO APARTMENT UNIT FEEDER SCHEDULE SIZES AND CALCS. CLOUDED DELTA 11 CHANGES ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49869	18041-10000-09041	601 E 23RD ST	90011	9	121-5A207 319	5127007001	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.02502	-118.26166	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49870	15041-10000-43046	964 S BERENDO ST PHASE 2	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.05378	-118.29358	12/21/15FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY BAPTIST CHURCH AND PRIVATE SCHOOL OVER ONE LEVEL OF SUBTER. PARKING GARAGE. NEW UNDERGRND SERVICE 2500A,480/277, 3-PHASE. TOTAL AREA (UNCONDITION + CONDITIONED) FOR ENERGY IS 229958 SQ FT. NONE METHANE ZONE ON ZIMAS*PROJECT WILL BE SPLIT INTO TWO PHASES. PHASE 2 OF 2. CHANGES INCLUDE SECOND FLOOR THRU 4TH FLOOR. ***PER APPLICANTS REQUEST NO CHANGES DONE FROM ORIGINAL TO NEW APPLICATION. BLDG PERMIT UNDER 12010-10002-02799)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49871	19041-20000-14903	2911 W BEVERLY BLVD	90057	13	138A201   301	5156019030	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.07133	-118.28058	800A 240/120V 3ph-4w service upgrade/service consolidation to (E) commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49872	15041-10000-11397	8746 N BURNET AVE	91343	6	195B145   695	2654007166	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Public Safety Only			04/16/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.22979	-118.46312	INSTALLATION OF FIRE WARNING SYSTEM IN A 3-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49873	10041-10000-21954	865 S FIGUEROA ST # 2700	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.04653	-118.26275	TENANT IMPROVEMENT IN OFFICES ; LIGHTING CONTROL PANEL IS EXISTINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49874	18041-10000-10939	1819 S OAK ST	90015	1	126A203   395	6001016901		Central				2244.10	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Closed	06/09/2022 12:00:00 AM	ADDRESS	34.0377	-118.27727	REEPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49875	10041-20000-21929	788 S CENTRAL AVE	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	34.03414	-118.24273	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49876	18041-10000-34684	6255 W SUNSET BLVD SUITE 850	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	TI TO EXISTING OFFICE AREA IN SUITE# 850. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-24415	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49877	16041-10002-10015	1245 W WILSHIRE BLVD # 780	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	PC FOR CHANGES TO APPROVED SET OF PLANS. USING LOW VOLTAGE LIGHTING CONTROLS. ALL CHANGES NOTED DELTA 1 ON PLANS. NO OTHER CHANGES NOTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49878	19041-10000-52670	3210 W RIVERSIDE DR	90027	4	153A205    26	5434016901	OS-1XL-RIO	Central	Hollywood	Hollywood United, Los Feliz	YES	1882.01	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	02/25/2020 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.11441	-118.27001	PC for power only. Scope includes new 400A480/277V 3 phase 4 service. Adding new electrical equipment that include panel boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49879	16041-20002-20464	14748 W KESWICK ST	91405	6	186B149    26	2210028008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.21015	-118.45472	7/14/17changes to an approved set of plans.  changes include updating plan to reflect field conditions.  this ia plan check only.  (((New service and build out for (E) plant cultivation building in response to code enforcement action.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49880	18041-10000-19534	3008 S SAN PEDRO ST	90011	9	118-5A207 267	5128015013	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.01804	-118.26336	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49881	13041-10000-17191	11705 W NATIONAL BLVD	90064	11	120B153  1026	4257011025	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.02268	-118.43912	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. TENANT IMPROVEMENT. SQUARE FOOTAGE IS 1348. THERE IS NO EMERGENCY LIGHTING IN THE SCOPE OF THIS WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49882	16041-10001-27381	1809 S WESTMORELAND BLVD	90006	10	126B193   735	5074016020	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM			PC Approved	11/04/2016 12:00:00 AM	ADDRESS	34.04097	-118.3068	11/04/2016 Changes to an approved set of plans. Changes include rearrange moduels on roof. Changes has been clouded.  {{{{{PC for PV1. Scope includes 32 modules and 32 microinverters installed in roof. Total solar system size is 7.68 KW.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49883	13041-10000-32727	12481 W FIELDING CIR	90094	11	102B161  1251	4211034032	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	33.97896	-118.41223	Plan check for power and energy. Fire alarm variance filed 6/19/2014.NEW 83 UNIT SENIOR INDEPENDENT APARTMENT OVER ONE STORY SUBTERENEAN GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49884	12041-20001-23469	11831 W VOSE ST	91605	2	183B169   185	2321004004	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.19855	-118.39129	"Changes to previously approved set of plans. 3000A 480 3-phase service changed to a 800A 3-phase delta service. Changes to voltage drops and fault current, all equipment inside building is the same as previously approved.  Plan Check Only for ""DELTA B"" Changes on page E2.0 & E2.1.NEW WAREHOUSE / OFFICE BLDG -"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49885	10041-10000-04088	8348 W BEVERLY BLVD	90048	5	138B173   478	5511010022	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/08/2010 12:00:00 AM			PC Approved	03/10/2010 12:00:00 AM	ADDRESS	34.07589	-118.37183	T-24 energy and emergency lighting plan check only.  Existing permit 10041-90000-02102.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49886	14041-20001-28601	8120 S WINSFORD AVE	90045	11	099B169  1130	4105027012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	33.96459	-118.38112	fee charge $0.00 by state senate bill no.1222revisions to an approved set of plans.  change of (1) inverter from 3.6kw to 3.8kw.PV1Central/String inverter standard plan. Rooftop solar array. System size: 7.4kW.(1) 3.8kW and (1) 3.6kW transformerless inverters(26) SunPower E20/327 pv modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49887	18041-20001-32466	13661 N BADGER AVE	91342	7	228B157   704	2511021019	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.32018	-118.41985	expeditepv1install roof mounted pv system sized 7.6KW AC interconnected with msp.  battery back up.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49888	17041-10003-26143	5602 W MANCHESTER AVE	90045	11	096B173   123	4125018020	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	33.95967	-118.3791	CHANGES TO AN APPROVED SET OF PLANS PER FIELD INSPECTION .ALL CHANGES ARE CLOUDED UNDER DELTA 3. CHANGES INCLUDE REVISING LIGHTING FIXTURE SCHEDULE FOR CORRECT WATTAGES AND CONTROLS IN PATEINT ROOMS. TITLE 24 FORMS REVISED TO REFLECT THE TOTAL WATTAGE INSTALLED.THIS IS PLAN CHECK ONLY!!!NOTE: PERMIT IS PAID UNDER MASTER APPLICATION.17041-70000-26143	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49889	11041-20001-02606	10819 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.26665	-118.52367	DELTA 1 REVISION TO APPROVED PLAN CHECK T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49890	15041-10000-38179	1801 W OLYMPIC BLVD	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Info Complete	12/08/2015 12:00:00 AM	ADDRESS	34.05046	-118.27663	PC FOR INSTALLATION OF GATE MOTOR. OPTIONAL PC FOR CUSTOMER REQUEST. GATE MOTOR INSTALLED ON Standby GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49891	12041-20000-24753	536 W AVENUE 46	90065	14	148-5A223  71	5466030023	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.10258	-118.21149	Enphase system on roof of SFD and detached garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49892	17041-10000-08489	3105 N NORTH BROADWAY	90031	1	138A223    27	5208006033	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.0739	-118.20873	TI TO MCDONALDS. NEW LIGHTING AND SOME PLUGS INSIDE AND NEW OUTDOOR LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49893	16041-20000-29513	933 N STONEHILL LANE	90049	11	138B141   155	4493022021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.07584	-118.48477	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49894	14041-20000-13576	5076 N ENCINO AVE	91316	5	171B129   284	2257016050	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.16371	-118.51404	Roof mounted PV system with Enphase Microinverter, model M250-60-2LL.  PV system size 4.77KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49895	15041-10000-31651	1930 E 15TH ST	90021	14	120A215   173	5167019023	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.02261	-118.23619	T-24. Tenant Improvement to an existing single story commercial building (wherehouse). Existing service and equipment. Installing new lighting and new receptacles. PC for enery only. Sq Ft = 165.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49896	16041-20000-23851	515 S FLOWER ST 2800-2850	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check Title 24 only in existing high-rise office space on 24th floor. Total area: 6,400 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49897	14041-10000-33841	652 N LA BREA AVE	90036	5	141B181   668	5525017011	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.08313	-118.34386	Plan check for Title 24 only. Project space is existing commercial (Wells Fargo Bank). Total lighting area = 3,210 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49898	13041-10000-15175	342 N SAN FERNANDO ROAD	90031	1	139-5A219   6	5447009017	MR2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			Not Ready to Issue	09/27/2013 12:00:00 AM	ADDRESS	34.07793	-118.22327	PC FOR POWER AND ENERGY. Goodwill Southern California. OFFICE BUILDING CAFETERIA INTERIOR TENANT IMPROVEMENT TO REMODEL KITCHEN, REVISE SEATING LAYOUT REMOVE / REBUILD NEW RESTROOMS,CONVERT 966 SF AREA  TO NEW OFFICES AND NEW OPENING ON EXTEIOR WALL  FOR NEW EXIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49899	14041-10000-17642	12701 N ENCINITAS AVE	91342	7	219B141    68	2604035014	[Q]CM-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.30058	-118.47489	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 8711 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49900	13041-10000-11611	16360 W ROSCOE BLVD	91406	6	192B137   317	2689023001	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.22113	-118.4895	permit to be pulled at epc counter only. PC FOR ENERGY.TI EXISTING OFFICE. LESS THAN 400A per applicant. only changing loads on panel 5A. 2STORIES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49901	13041-20000-26743	10454 W CHEVIOT DR	90064	5	126B161   702	4318021013	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	ADDRESS	34.03743	-118.41318	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING 22 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. PC REQUIRED. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49902	16041-20000-34633	8425 N SEPULVEDA BLVD	91343	6	192B145   280	2654027006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Closed	09/10/2018 12:00:00 AM	ADDRESS	34.22371	-118.46799	Plan check for Title 24 only. Project site is a new state-approved coach for office and restrooms accessory to new auto sales dealership. Project scope is a lighting within the coach. Total lighting area = 2,024 sq. ft. Note: Building permit has been pulled under 16010-10000-03127	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49903	14041-10001-26245	843-845 N SEWARD ST	90038	4	141B185    46	5533024021	MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.08649	-118.33326	06/07/16Changes to approved set of plans. Changes include replacing/removing/adding lighting fixtures on floor plans. Changes are not under a delta number since lighing fixtures have been replaced with completely different fixture type from original set.  (((((Plan check for energy only 2013  Standards.  Corrections issued for 9/23/2014. Approved 11/12/2014.  Renovation of existing 2566 sq. ft. office building (ground floor) and addition of 1690 sq. ft. (second floor). Indoor and outdoor lighting. BLDG#14014-10-04162. Changes on plans include added controls for outdoor and clarifying information on forms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49904	19041-10000-42029	1500 S GRANVILLE AVE	90025	11	126B149   386	4262006032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	04/13/2020 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	PIN	34.04297561	-118.45708387	$0 Fee per AB 1414. Plan check for a PV2 73.3KW AC/ 73.1kW DC roofmounted system. Scope includes (1) load center, (3) inverter, (186) modules, and (75) P860 optimizers and (36) P400 Optimizers interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49905	12041-10000-12356	1628 N EL CENTRO AVE	90028	13	148-5A189 201	5546027400	C4-2D	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.10066	-118.32361	RENOVATION OF AN EXISTING 55,500 SF SPORTS CLUB WHICH INCLUDES new interior finishes, revised locker rooms, plumbing fixture and electrical fixture changes (no increase in service load).  Remove and reconfigureation of interior walls.  Improvement to exterior site hardscape and building entrance.  No change in building floor area. (Bldg Permit# 12016-10K-07977)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49906	14041-20000-29117	18411 W CLARK ST #302	91356	3	174B125   488	2160010037	C2-1, P-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.16989	-118.53355	T.I. to existing medical building.  Install new subpanel, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49907	15041-10001-21023	4245 N LANKERSHIM BLVD	91602	2	165B177   832	2423022045	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM			PC Approved	04/21/2016 12:00:00 AM	ADDRESS	34.14719	-118.3642	Changes to approved set under Delta-2: added receptacles and light fixture (L-10) and revised qty of some light fixtures.  New panel, total connected load still under 400A.  This is supplemental PC only, permit under 15041-10000-21023<<PC FOR ENERGY. REMODELING OF BMW DEALERSHIP. TOTAL AREA 20202 SQ FT.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49908	15041-10000-01387	11811 W CULVER BLVD	90066	11	111B161   959	4233022010	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			01/16/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	33.99735	-118.41647	New 5 story 27 unit apartment building with 4 typical units and 1200 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49909	18041-10000-46767	5815 S NORMANDIE AVE	90044	8	108B193  1343	5003033013	[Q]CM-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	33.98937	-118.30036	PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 600A SERVICE 480/277 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD. NEW OUTDOOR LIGHTING. TOTAL NEW CONNECTED LOAD IS APPROX 300A WITH TOTAL AFFECTED AREA = 3651 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49910	13041-20000-00114	13833 W VENTURA BLVD # 105	91423	4	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.1487	-118.43426	T-24 lighting plan check for new beauty salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49911	13041-20000-07005	1300 N HIGHLAND AVE	90028	4	144B185   120	5547033400	C2-1-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.09453	-118.33843	Plan check for energy and emergency lighting. Fat Sal's Hollywood. Permit on 13041-90000-03266.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49912	18041-10000-43991	1315 W COLTON ST	90026	1	135A209   281	5160019003	CW	Central	Westlake	Echo Park	YES	2080.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	05/02/2024 12:00:00 AM	ADDRESS	34.06323	-118.257	plan check for pwr and t-24. new 60-unit apartments.6 residentil levels, 2 subterraneain parking levels. 2000A new service , 120/208V. with an EV charger panel. scope of work is 104k sq ft w/15 typical unit. missing panel EV.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49913	19041-10000-04024	10966 W RATNER ST	91352	6	189B173   161	2409003049	[Q]C2-1L-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.22	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	04/11/2020 12:00:00 AM	ADDRESS	34.21679	-118.36932	NEW FIRE ALARM SYSTEM IN THE BULDING. SCOPE INCLUDES 1 FA PANEL, 139 DEVICES WITH WITH POWER SUPPLIES AND CONTROL PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49914	17041-20000-13358	5929 W SUNSET BLVD	90028	13	147A191    69	5545009035	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.09821	-118.31893	5/29/19changes to an approved set of plans, changes noted delta 8.  changes to light fixtures and energy calculations. no new equipment, no new loads.((((Plan check for power and energy. New 22-story mixed use building: 299 residential units, ground floor retail, 2 floors of office, and 6-levels of parking (4 levels subterranean). (Core and shell only for commercial uses.) TI for commercial uses under separate permit. 5000A service.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49915	17041-10000-18160	900 N ALAMEDA ST 3rd floor	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC for new installation of equipment OVER 600A. Scope includes  PDU'sUPS AND PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49916	13041-10000-30860	1122 S WESTWOOD BLVD	90024	5	132B153   211	4363022006	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.06024	-118.4449	Remove HID light fixtures and replace with new fluorescent fixtures in retail space.  Title 24 only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49917	16041-20000-15404	4630 W HOLLYWOOD BLVD	90027	13	147B197   478	5542014008	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.09993	-118.29023	Plan check for Title 24 only remodel interior T.I. in existing space. Total area: 938 sq ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49918	18041-20000-32106	20790 W NORDHOFF ST Unit 4	91311	3	198B109   218	2780001059	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.23523	-118.58748	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,227 sq. ft.Note: Building application has been generated under 18016-20000-27123	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49919	11041-10000-12785	700 W WORLD WAY WEST TERMINAL-# 7	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/11/2011 12:00:00 AM	PIN	33.94386803	-118.39979044	REPLACEMENT OF4 ELEVATORS IN TERMINAL 7 AT LAXPLAN CHK IS REQUESTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49920	16041-20001-00100	281 N BENTLEY CIR	90049	5	138B149    66	4366004018	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM			PC Approved	03/09/2016 12:00:00 AM	ADDRESS	34.07702	-118.45744	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49921	19041-20000-02272	8201 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Issued	01/18/2019 12:00:00 AM	ADDRESS	34.21793	-118.6063	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is an indoor sign. Total lighting area = 93 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49922	18041-20000-17347	11384 N REY TERRACE WAY	91342	7	213B177   290	2529012041	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.27664	-118.36081	Plan check for PV roof mounted system, system size: 10.4kW with 30 modules and 2 inverters(5.2kW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49923	13041-20000-20522	1534 W 16TH ST	90732	15	012B193   409	7560025009	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	33.72988	-118.31109	solar single family, service upgrade 10.78 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49924	14041-20000-06251	22605 W GAULT ST	91307	12	183B097   861	2024040009	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.19997	-118.61934	PV1 ROOFTOP MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49925	15041-10000-00524	3951 W INGRAHAM ST 1-13	90005	10	132B193   120	5092030023	R4P-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Apartment			01/08/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.06079	-118.31303	Full plan check for a new 6-story apartment building with 13-unit; project includes a 1000-Amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49926	11041-10001-01371	10250 W SANTA MONICA BLVD # 113	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Info Complete	03/03/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	SUPPL. APPLICATION FOR CHANGES TO APPROVED PLANS.   TI - REMODEL EXISTING RETAIL SPACE  (#113)  INCLUDING; CEILING, PARTITIONS, STOREFRONT (LIGHTING & M.E.P. WORK).PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49927	10041-20000-13843	725 S FIGUEROA ST 27, 28 & 2-9th Floors	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Expired	05/08/2021 12:00:00 AM	ADDRESS	34.04886	-118.26071	TI FOR OFFICE BUILDING. ENERGY ONLY.permit for the new circuits on the 27, 28 & 29th Floors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49928	18041-20000-35112	17310 W BRONTE PL	91344	12	222B133   295	2602011007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.30487	-118.51105	pv1install roof mounted pv system sized 9.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49929	17041-10000-24960	5315 N LEGHORN AVE	91401	4	171B161   243	2345019006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.16711	-118.41599	PC FOR PV SYSTEM USING AC MODULES. TOTAL OF 35 MODULES. TOTAL SYSTEM SIZE IS 11.2KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49930	18041-10000-18956	1114 E 8TH ST #102	90021	14	124-5A213 367	5146019007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.03501	-118.24516	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR INDOOR USE. TOTAL AFFECTED AREA IS 1200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49931	16041-10000-43335	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	TI TO EXISTING BUILDING - NEW MECHANICAL ROOMS AND CORRIDOR AT 2ND FLOOR; (N) MECHANICAL SHAFT FROM GROUND LEVEL TO 2ND FLR. PLAN CHECK FOR ENERGY ONLY TOTAL SQ. FT. 2430.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49932	10041-10002-10084	530 W 27TH ST	90007	9	121-5A203 130	5123018019	(T)(Q) C2-2, D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM			PC Approved	10/10/2010 12:00:00 AM	ADDRESS	34.0269	-118.27607	Change the previosly approved plan. Change the size of the conductor, and VD calc. (((((((((((( New fire Alarm system for 5-STORY, TYPE III-A, 161-UNIT STUDENT HOUSING OVER TYPE 1-A, 2ND FLOOR GARAGE OVER TYPE 1-A,  (total 7-story building with one level basement parking per granted modification, see comments).((((( install new  voice evac fire alarm systems)))))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49933	14041-20000-24663	9667 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.24627	-118.5363	Plan check for replacement of receptacles in medical office tenant space.  All wiring existing to remain other than receptacles serving the rehab area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49934	19041-10000-14190	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Issued	12/30/2019 12:00:00 AM	ADDRESS	34.06086	-118.27891	POWER AND ENERGY PLAN CHECK FOR A HISTORIC BUILDING TI. SCOPE INCLUDES 3 EXISTING SERVICES ( MSA 2000A 480/277, MS 2500 208/120 AND MSB 2000 480/277), NEW PANELS, EQUIPMENT AND  LIGHTING. TOTAL AFFECTED AREA   14244 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49935	13041-20000-16268	1450 W JAMES M WOOD BLVD	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	PIN	34.04924238	-118.27035805	"NEW PV2 SYSTEM. LAW SCHOOL. ROOF MOUNTED. FOR THIS APPLICATION(2 OF 3) SYSTEM SIZE IS 48KW. PV MODULES LOCATED ON THE ""RAINS BUILDING"" TOTAL OF 240 MODULES. SINGLE SET OF PLANS HAVE BEEN SUBMITTED. ASSIGN ALL THREE APPLICATIONS TOGETHER. BUILDING CONTAINS OWN SERVICE LINE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49936	19041-20000-41449	23716 W ARMINTA ST	91304	12	189B089   264	2020015035	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	34.21308	-118.64431	PV roof mounted system, PV system size: 11.2KW DC, 10.182KW AC CEC with 28 AC Modules, sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49937	11041-10000-06528	11715 W GOSHEN AVE	90049	11	129B145   485	4265010005	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			04/01/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.05008	-118.46232	NEW FIRE ALARM SYSTEM FOR 9 UNIT APARTMENT BUILDING.  1 FIRE ALARM CONTROL PANEL.  87 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49938	15041-10000-25252	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/05/2015 12:00:00 AM			PC Approved	08/05/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	Power plan check( per customer request)  for a new Kiosk (Los Angeles magazine)  located in Terminal-6  of LAX airport. Approved Per F.Y	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49939	12041-20001-22195	6651 N FALLBROOK AVE	91307	3	180B097   183	2038040013	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.1915	-118.62498	Changes to approved set of plans. Most equipment relocated from previous plans. Only loads on right side (even circuits) of Panel LF, loads on left side (odd circuits) of Panel LF1, 112.5kVA transformer, and 1200A feeder to Distribution Panel HDP are new; about 9000sqft of lighting has been revised. (ALL CHANGES ARE PER APPLICANT, PLEASE VERIFY DURING PLAN CHECK)50,644 SF Health Club.  New 1600 Amp swb, circuits, and lighting.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49940	19041-20000-01481	19530 W TUBA ST	91324	12	204B117   254	2726009006	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.25621	-118.55865	PV1.  Install 10 kW AC / 9.28 kW AC-CEC roof mounted grid tied PV system.  (29) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49941	16041-10001-32754	5201 N LAUREL CANYON BLVD	91607	2	171B165  1234	2347018012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.16518	-118.39681	Changes to approved set.  New lighting layout and updated Title 24 sheets.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49942	14041-20001-16871	2254 N MICHELTORENA ST	90039	4	148-5A205 259	5432023015	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.10099	-118.26877	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.88KW INTERCONNECTED WITH MSP.(26) YINGLI ENERGY SOLAR MODULES YL2510P(26) M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49943	14041-20000-00236	15207 W SUNSET BLVD	90272	11	129B129   809	4423016073	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.04647	-118.52446	Office T.I. on the 2nd floor of an existing office building. Title 24 only. Total new connected load does not exceed 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49944	15041-10000-32601	1110 S WESTERN AVE 101	90006	10	129B193   694	5080010002	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.05041	-118.30886	FULL PC. FIRST TIME TENANT. SCOPE INCLUDES NEW LIGHTING FOR EXISTING COMMERCIAL BUILDING (COFFEE SHOP) AND ONE NEW PANEL FOR PLUG LOAD. TOTAL AREA IS 1460 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49945	14041-20000-17981	1642 S CHASTAIN PKWY EAST	90272	11	138B121    90	4431041008	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.07556	-118.54816	PV1Install roof-mounted solar array on SFD. System size: 5kW(1) SB5000TL-US-22 transformerless inverter(18) Solar World SW275 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49946	14041-20000-32559	17624 W VINCENNES ST	91325	12	198B129   159	2766001027	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.2408	-118.51875	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main breaker to 175A.System size: 10kW (5+5). Ungrounded system.44 255W pv modules across 4 strings (inv 1: 10+10; inv 2: 12+12).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
49947	19041-20000-07837	1021 W CHILDS WAY bdx	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.02281	-118.29046	ti to an existing commercial building. adding new lighitng new controls to existing panels.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49948	16041-10000-35587	4245 N LANKERSHIM BLVD	91602	2	165B177   832	2423022045	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.14719	-118.3642	T-24, PC FOR ENERGY ONLY. TI TO AN EXISING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 35000 SQ. FT. (outdoors)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49949	15041-20001-35422	17144 W KINGSBURY ST	91344	12	207B133   624	2695006029	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	34.26343	-118.5071	**Expedite Fee**PV1, roof mounted solar system 6kW AC.(27) modules: HANWHA Q-CELLS Q-PEAK-BLK-G3-270W(1) inverter: Solar Edge SE6000A-US (240V)(1) Power Optimizer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49950	14041-20000-12839	3430 S VERMONT AVE	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.02479	-118.29132	Install Temporary Research Facility (TRF) modular trailer at USC, Phase 3.  Modular trailer are approved by the State.   Install new 800 panel to feed the modular trailer subpanels. plan check for power only for power to trailers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49951	11041-10000-10033	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	34.09786	-118.29745	Provid power for new UPS for local area network upgrade, new XFMR, receptacls and panel boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49952	13041-10000-29389	8666 W PICO BLVD	90035	5	132B169  1067	4303011004	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.05404	-118.38084	PLAN CHECK FOR TITLE 24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  2000 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49953	15041-20001-10564	4761 N HASKELL AVE	91436	5	168B141   985	2261009028	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM			PC Approved	05/08/2015 12:00:00 AM	ADDRESS	34.1568	-118.47514	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 9kW (3+6). Ungrounded system. (33) 327W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49954	16041-20001-09437	6254 N BEEMAN AVE	91606	2	177B161   177	2332015002	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2016 12:00:00 AM			PC Approved	03/25/2016 12:00:00 AM	ADDRESS	34.18458	-118.40724	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 15.2kW (7.6+7.6). Ungrounded system. Each module has a 300W power optimizer.(55) 300W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49955	11041-10000-08121	5347 S 4TH AVE	90043	8	108B189   528	5006030036	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM			Corrections Issued	05/01/2011 12:00:00 AM	ADDRESS	33.9937	-118.32164	NEW ONE STORY MIDDLE SCHOOL FLEX CLASS BUILDING. NEW PANEL BOARD & BRANCH CIRCUITS. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49956	18041-10000-44961	2117 S BUTLER AVE	90025	11	123B153    39	4260005902	R2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.0372	-118.44495	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49957	16041-10000-01115	5126 N DAHLIA DR	90041	14	163-5A227 359	5669012015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Issued	01/13/2016 12:00:00 AM	ADDRESS	34.14037	-118.19959	PV1, rooftop mounted 15.2 kW Ac system interconnect with 200 MSA, 46 modules, (2) Fronius Primo 7.6, (2) load centers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
49958	16041-30000-18199	1901 S LINCOLN BLVD	90291	11	108B149    91	4241024001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	33.99585	-118.45685	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,520 sq. ft.Note: Building permit has been pulled under 15016-20000-27186	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49959	13041-10005-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.06488	-118.47066	"CHANGES TO AN APPROVED SET OF PLANS FOR A SCHOOL. ALL CHANGES ARE CLOUDED UNDER DELTA 26A. CHANGES INCLUDE REVISING FEEDER SCHEDULE TO INCLUDE FEEDER TAG# 600.3 AND CHANGING FEEDER CONDUCTORS FROM ""MST"" TO ""MS2"".NOTE: PERMIT HAS BEEN PULLED UNDER THE MASTER APPLICATION."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49960	17041-10000-45591	331 E 1ST ST	90012	14	130-5A215 321	5161012012	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/27/2017 12:00:00 AM	ADDRESS	34.04992	-118.23998	PC for T24 only for existing coffee shop TI. Installing new lights and equipment. Total area 276sqft. B# 17016-10000-31540.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49961	17041-10000-18168	741 S ALVARADO ST	90057	1	132A203   180	5141018014	C2-1	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.05545	-118.27764	CORE AND SHELL IN AN EXISTING BUILDING. SCOPE OF WORK INCLUDES A SERVICE UPGRADE TO 800 AMPS, LIGHTING AND RECEPTACLES IN THE TENANT SPACES. TOTAL SQ. FT. 10213	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49962	17041-10000-37320	11058 W CHANDLER BLVD BLDG 1	91601	2	171B173  1406	2350014015	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Issued	12/27/2017 12:00:00 AM	ADDRESS	34.168	-118.37216	INSTALL NEW F.A SYSTEM ON 5 STORY MIXED USE BUILDING. (15)PANELS  (1049) DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49963	10041-10000-15549	601 N LARCHMONT BLVD	90004	4	141B189   652	5523012013	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			08/10/2010 12:00:00 AM			PC Approved	08/10/2010 12:00:00 AM	ADDRESS	34.08187	-118.32385	REMODEL OF OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49964	17041-20001-38544	3285 S MOUNTAIN VIEW AVE	90066	11	117B153   786	4248014037	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.01573	-118.43861	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and DC coupled battery backup system for SFD.Total pv system size: 7.6kW.(1) 7.6kW SolarEdge inverter.(19) 290W pv modules.(19) 300W power optimizers.(1) 9.8kW DC battery bank.(1) 5kW auto-transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49965	18041-10001-46331	2155 N WESTRIDGE ROAD	90049	11	138B133   335	4492014008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.07382	-118.50352	(EXPEDITE PER APPL REQUEST)NEW ROOFTOP SOLAR SYSTEM CONSIST OF 40 MODULES (HANWHA Q-CELLS) AND 40 OPTIMIZERS (SOLAR EDGE) AND 10KW INVERTER ,  2 - 14KW ENERGY STORAGE SYSTEM.  SYSTEM SIZE IS 12.2KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49966	09041-20002-24320	10747 W MAGNOLIA BLVD	91601	2	171B177   600	2416024009	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			07/24/2012 12:00:00 AM			PC Info Complete	08/29/2012 12:00:00 AM	ADDRESS	34.16505	-118.36517	Plan check power and energy for new Delta 2 and Delta 3 modifications to the approved plan for a  126 unit apartment building.   Installing new circuits for signs, exterior lighting, and exercise equipment, new panel and changing feeder details for the apartment unit feeders.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49967	18041-20000-12224	500 S MATEO ST 102	90013	14	127-5A217  67	5163018005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.04146	-118.23294	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 5,327 sq. ft.Note: Building application has been generated under 17014-10000-06345	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49968	12041-10000-03169	11305 W MOORPARK ST	91602	2	165B173   315	2366003013	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.15052	-118.37715	New fire alarm system for 6 units appartment BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49969	13041-20000-00179	11241 N MONTGOMERY AVE	91344	12	210B141   197	2666022024	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.27486	-118.48182	New 8.46KW rooftop mounted PV system for an existing single family residence.   Part of the system is existing and additional modules are being added.  <<<ALL SPLICES MUST BE MADE IN THE PROPER ENCLOSURE>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49970	11041-10000-16181	11061 N BALBOA BLVD Ste 3	91344	12	210B133   507	2696017023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.27171	-118.50242	T.I.  Damage repair to a fire damaged restaurant.  Per inspector's request, plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49971	18041-10000-11916	4312 W JEFFERSON BLVD	90016	10	120B181   773	5046008004	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.02541	-118.34343	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR OFFICE SPACE. NEW CONNECTED LOAD IS APPROX 350A ON A 120/240V 3 PHASE SYSTEM - TOTAL AFFECTED AREA = 8000 SQ. FT. (25 SQ. FT. FOR OUTDOOR)ORIGINAL CORE AND SHELL DRAWINGS HAVE BEEN ATTACHED FOR REF.(B#17016-10001-37064, 16014-30003-05628)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49972	16041-30000-26263	6171 W CENTURY BLVD	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHTING.  TOTAL SQUARE FOOTAGE 2900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49973	15041-20000-23322	13249 W SHERMAN WAY	91605	2	183B157    50	2327002036	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.20136	-118.42191	plancheck for t24 energy. tenant improvement. Convert machine shop/warehouse to warehouse with accessory retail showroom, remodel exterior fascade. 10640 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49974	12041-10001-28786	11111 W SANTA MONICA BLVD ste 150	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Approved	02/25/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	changes to approved set of plans: demo ran into air shaft for electrical room. couldn't demo that so they revised the plans by shifting the bathroom layout and added some receptacles. lighting and power revisedT.I. On the ground floor for a high rise building.  Project is converting office space into a gym.  Change of use is triggered.  Full plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49975	17041-20000-18368	21650 W OXNARD ST 1650	91367	3	177B105    83	2146006042	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti to an existing commercial building.  adding ne lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49976	16041-20000-26392	400 N AMALFI DR	90272	11	123B129   407	4408024005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Expired	08/28/2023 12:00:00 AM	ADDRESS	34.03351	-118.51481	INSTALLATION OF A BATTERY BACKUP SYSTEM TO AN EXISTING PV SYSTEM.  8KW. SONNEN ECO 16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49977	16041-10001-41964	6701 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM			PC Approved	03/15/2017 12:00:00 AM	ADDRESS	33.93211	-118.40783	CHANGES TO APPROVED SET OF PLANS. SCOPE OF WORK NOW SHOWS HALLWAYS AND 2 OTHER ROOMS. PLANS ARE NOW ENGINEER DESIGN. RECHECKING SET AS NEW. STILL PC FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49978	15041-10000-40704	660 S FIGUEROA ST	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM			PC Info Complete	02/26/2016 12:00:00 AM	ADDRESS	34.04953	-118.25947	Full plan check for a change or use from business to restaurant. Scope includes a completed renovation and new tentant build out, area covers one halft of the first floor of a high rise building and a portion area of the basement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49979	16041-10001-04555	350 S GRAND AVE lobby	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE LOBBY LEVEL. SCOPE INCLUDES NEW LIGHTS FOR THE OUTDOOR CANOPY AND NEW LIGHTS FOR THE LOBBY AREA. TOTAL AFFECTED AREA IS 2396 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49980	14041-10000-05252	3625 S GRAND AVE	90007	9	118-5A203 223	5122023030		South Los Angeles				2311.00	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM			PC Info Complete	02/26/2014 12:00:00 AM	ADDRESS	34.01785	-118.2778	T-24 ONLY, aDDING LIGHTINGS ON THE OUTSIDE, ALSO INSTALL ONE LIGHT FOR DECORATIVE PURPOSES IN WINDOS ON FLOOR 3RD THRU 9TH FLOOR , CONTROL IS PROVIDED BY CONTACTORS.  cLEARANCE FOR cra IS OBTAINED THROUGH BUILIDNG PERMIT NO. 14016-10000-01528.  rti ISSUED AND PERMIT FEES UNDER INSPECTION.  ONE PANEL ON 9TH FLOOR IS ADDED WITH CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49981	18041-10000-04881	415 N FAIRFAX AVE	90036	5	141B177  1436	5527031024	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.07868	-118.36162	PC FOR  CONVERT (E) URM TAKE-OUT RESTAURANT TO RETAIL FOR T-24 ENERGY ONLY. SCOPE INCLUDES TBD. TOTAL AFFECTED AREA 5027 SQ FT .B#18016-10000-02087	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49982	17041-10005-32559	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.06371	-118.2982	PLAN CHEK ONLY. DELTA 5 CHANGES TO APPROVED SET, CHANGES INCLUDE:*ADDED MINI INVERTER TO PROVIDE EMEGRENCY LIGHTING TO BALCONLY*ADJUSTED LIGHTING PLAN AND UPDATED T24 ACCORINGLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49983	18041-10000-13495	1140 S GAYLEY AVE	90024	5	132B149   112	4363023030	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.05955	-118.44565	Install 15 new devices and a RPS to an existing Fire Alarm system in an existing bilding.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49984	16041-20000-19085	7347 N ATOLL AVE	91605	2	186B157   409	2327001020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.20424	-118.42119	Plan check for power only. Project scope is combining two existing buildings being combined into a single building, which a change of use from manufacturing to distribution/warehouse. Work includes a new 600-amp 240V 3ph service and associated distribution boards and loads.Note: Title 24 has been plan checked and approved under 16041-20000-03757. No changes made to lighting on this plan; lighting sheets included for reference.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49985	15041-10001-35253	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	Changes to approved set.  Changes to lighting fixture type and layout.  Title 24 sheets updated.  Changes are clouded.Etihad Airways lounge tenant improvement in Tom Bradley International Terminal.  Plan check for power and energy.  Plan checker to verify service and distribution load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49986	17041-30000-28288	1145 S GAYLEY AVE	90024	5	132B149   118	4363023033	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.05935	-118.44602	Plan check for power and energy T.I. of level 1 and 2 in existing 3 story commercial building. Existing electrical service equipment panel board. Total area: 29,613 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49987	16041-10000-44622	12842 W VENTURA BLVD	91604	2	165B161  1046	2384008027	(Q)P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.14484	-118.4131	PC FOR POWER AND ENERGY. T.I IN A RALPH GROCERY STORE. NEW INTERIOR LIGHTING AND RELOCATING EXTERIOR PARKING LOT POLE FIXTURES. CONNECTED LOAD >400A. TOTAL INTERIOR LIGHTING AREA 24110 SQ FT. THE EXTERIOR LIGHTING T24 FORMS ARE MISSING IN THE PLAN.B # 16016-10000-30457	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49988	15041-20001-15804	6324 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	34.18512	-118.59722	10/28/2015 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Type of light fixture has changed. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Title 24 plan check only.  Total area = 2,090 sq. ft.  T.I. to existing commercial space.  Change of use from restaraunt to office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49989	17041-20000-32559	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.06371	-118.2982	Plan check for power only. Core and shell/Change of use from residential studio to office. Building is historical. New 1,000A 277/480V 3ph 4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49990	13041-20000-04798	523 W 6TH ST 515	90013	9	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	Full plan check for lighting and powers in dental office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49991	19041-10000-17633	7007 W ROMAINE ST	90038	4	144B181   604	5532030011	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.08901	-118.34188	INSTALLING ADDITIONAL 108 DEVICES AND 2 POWER SUPPLIES TO AN EXISING FIRE ALARM SYSTEM IN AN EXISTING BULDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
49992	11041-10001-04869	10100 W SANTA MONICA BLVD	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM			Reviewed by Supervisor	04/25/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	ADDITION TO THE PLAN WAS SUBMITTED UNDER 11041-10K-04869. 2 NEW X-FORMER AND PANELS.  (((((((TI IN 13 & 14th FLOOR OF EXISTING OFFICE BLDG. EPC IS FOR POWER & ENERGY.))))))) EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49993	11041-10000-25941	124 N UDINE WAY	90077	5	138B153    15	4362011007	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2011 12:00:00 AM			PC Info Complete	01/25/2012 12:00:00 AM	ADDRESS	34.07776	-118.44393	Remodel of a 10,000 sq. ft. single family residence.  Upgrade to a new 600A service.  12 new panels, and 157 new circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49994	18041-10000-02778	5533 W HOLLYWOOD BLVD	90028	13	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM			PC Approved	02/05/2018 12:00:00 AM	ADDRESS	34.10188	-118.31038	PC (T24 only) FOR  COMMON AREA TI IN AN  A MIXED USED APARTMENT BUILDING. SCOPE INCLUDES INSTALLATION OF NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 3605. THIS IS PLAN CHECK ONLY!PERMIT PAID UNDER  17041-10000-40497B# 16016-20000-29632	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49995	16041-10000-26511	8202 W MELROSE AVE	90046	5	141B173   467	5528012033	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.08352	-118.36822	T-24, PC FOR ENERGY ONLY. change of use from retail, office and artist in residence to retail and office. SCOPE INCLUDES ONE NEW PANEL, NEW INTERIOR AND EXTERIOR LIGHTINGS. TOTAL AFFECTED AREA IS 10147 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49996	11041-10000-10090	10327 W SANTA MONICA BLVD	90024	5	132B157   401	4327017014	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Public Safety Only			05/17/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	PIN	34.05913764	-118.42238861	INSTALLATION OF A FIRE WARNING SYSTEM INSIDE THE PARAMOUNT RECORDING STUDIO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49997	16041-10000-23623	1149 S HILL ST 11TH FLR	90015	14	126A207   101	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Issued	07/18/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	T.I. ON THE 11TH FLOOR OF AN EXISTING BUILDING, SCOPE OF WORK INCLUDES HALLWAY AND CLASSROOM REMODEL ON THE NORTH-WEST CORNER. TOTAL SQ. FT. 1350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
49998	15041-20001-13484	1930 S LONG BEACH AVE EAST	90058	9	118-5A213 351	5167013042	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.01969	-118.2427	Expedite per applicant request{{{{{{Plan check for solar mounted roof for commercial with system size 82.6 kW and 259 modules and 3 inverters(26.8kW) combine to load center(200A)}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
49999	18041-10001-18529	15350 W OXNARD ST BLDG - B	91411	4	177B145   462	2243001031	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	34.17919	-118.46783	"DELTA ""1"" CHANGES TO APPROVED PLANS FOR BULDING ""B"". NEW TRANFORMER, PANELS, CIRCUITS, T-24 UPDATED.Note that permit for original plans has not been finalised  as of 10/03/19"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50000	17041-30000-05185	1025 S ABBOT KINNEY BLVD	90291	11	108B145   928	4239021026	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	33.99217	-118.47173	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to a restaurant on the ground floor. Total lighting area = 1,655 sq. ft.Note: Building permit has been pulled under 16016-10000-01852	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50001	10041-20000-06174	8522 W BEVERLY BLVD 779	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.07588	-118.37782	T.I within suite 779. this plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50002	10041-10000-20226	5705 S VERMONT AVE	90037	9	108B197  1290	5002018011	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	ADDRESS	33.99016	-118.29169	T.I. - Change of Use from Retail to Dental Office (Addition of 1465 sq. ft. to expand Dental Office permitted under 08016-20000-07096).  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50003	10041-10000-22274	1205 E PLAZA DEL SOL	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04896	-118.22658	Solar voltaic system installed on the roof of the building.  Consists of  9 modules, 9 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50004	13041-20000-17419	15426 W LEMARSH ST PV-1	91345	7	204B145   561	2660003020	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.25535	-118.46841	PV-1. Solaredge with power optimizers. Transformerless. Two 5kW Inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50005	16041-10000-44563	1828 E CESAR E CHAVEZ AVE 600	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.05014	-118.21571	Full plan check for TI medical office surgery center (non-oshpod 3) 6-story building. Adding new equipment and lighting. Total sqft =  6680.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50006	19041-10000-38595	13201 W SATICOY ST	91605	2	186B157   188	2303017018	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	34.20784	-118.41984	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50007	16041-20000-13422	12886 W KAMLOOPS ST	91331	7	204B161   559	2623026021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Expired	06/28/2018 12:00:00 AM	ADDRESS	34.25395	-118.4132	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.Existing solar array on roof. New system is 3.8kW, ungrounded. (15) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50008	17041-30000-40714	1999 S AVENUE OF THE STARS 34th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only in existing high rise building office T.I. renovation with new lights and power outlets. total area: 6,754 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50009	16041-20000-02247	17907 W CALVERT ST	91335	5	177B129   220	2123034012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	PIN	34.18212344	-118.52331989	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (2) inverters, (38) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50010	16041-20000-32813	16659 W ADDISON ST	91436	5	171B137   121	2259003032	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.16405	-118.49648	Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (36) AC modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50011	10041-10000-08363	1321 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			05/05/2010 12:00:00 AM			Corrections Issued	05/16/2010 12:00:00 AM	ADDRESS	34.05129	-118.22464	PV system for an appartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50012	16041-10000-45023	3280 S MOTOR AVE	90034	5	123B161   963	4314024020	M1-1	West Los Angeles	West Los Angeles			2699.07	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.02969	-118.41085	"Full plan check TI to a 2 story offce building. Adding (2) switchboards rated at 600 amps ""MT1"" for the first floor and 800 amps ""MT2"" for the second floor. New equipment, power, and lighting. Total sqft = 24510."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50013	18041-20000-48494	16507 W OTSEGO ST	91436	5	171B137   239	2259016026	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.16278	-118.49273	Plan check for a PV1 roof-mounted PV system. System size is 11.53 kWdc/10.27 kWac-CEC and consists of (32) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50014	15041-20002-07078	17302 W OSBORNE ST	91325	12	195B133   132	2768018013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2015 12:00:00 AM			PC Approved	04/01/2015 12:00:00 AM	ADDRESS	34.23324	-118.51172	[[[4/1/15  CHANGES TO APPROVED SET. MINOR CHANGES TO SINGLE LINE DIAGRAM PAGE; REMOVIE NOTES FOR 6X6 JOX, REDUCTIONG #8 TO #10 CONDUCTOR AND REMOVING 22K AIC NOTE]]]]Plan check for PV system roof mounted system with 36 enphase microinverter 250. Total system size: 9kW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50015	18041-20000-43436	8700 W CHALMERS DR	90035	5	132B169   109	4333012025	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	06/26/2020 12:00:00 AM	ADDRESS	34.06082	-118.38155	Plan check for a fire alarm system for a 4-story, 8-unit apartment building. System consists of (1) FACP and (35) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50016	13041-20001-34535	3440 S MILITARY AVE	90034	5	120B157   883	4251025024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.02178	-118.41986	EXPEDITE FEES ONLY  <<<New rooftop PV system using Enphase 215 microinverters.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50017	14041-10000-00364	9797 W EASTON DR PV1	90210	5	150B157    90	4384019009	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.10879	-118.43123	PV1, PROPOSED GROUND MOUNTED SOLAR PV SYSTEM 28.8 kW SYSTEM. TRANSFORMERED INVERTERS , WITH 120 TRINA 240W MODULES. TOTAL OF 12 STRINGS  WITH CONFIGURATION OF 10 MODULES PER STRING. (4) TOTAL COMBINER BOX, (1) 150A AC LOAD CENTER.MODULE SPECS: (120) TRINA 240W (TSM-240PA05)INVERTER SPECS: (4) SUNNYBOY SMA 7000W INVERTER W/ INTEGRATED DC DISCONNECTCOMBINER BOX SPECS: MIDNITESOLAR MODEL NO: MNPV4HV-DELUXE 80A2012 SENATE BILL 1222 DOES NOT APPLY TO GROUND-MOUNTED SOLAR INSTALLATION. BUILDING PERMIT: 13024-10000-00020note to plan checker: no solar clearance required at the electrical plan check counter due to plans already being checked @ building department	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50018	19041-30000-22161	6303 N OWENSMOUTH AVE 2nd Floor	91367	3	177B105   123	2146029016	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.18474	-118.60182	Plan check for Title 24 only. Project site is a part of the 2nd floor of an existing high-rise building. Project scope is a tenant improvement. Total lighting area = 4,160 sq. ft.Note: Building permit has been issued under 19016-30000-17100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50019	14041-10000-02957	10643 W SUNSET BLVD	90077	5	138B153   103	4362009012	A1-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.07571	-118.44485	PLAN CHECK FOR EMERGENCY LIGHTING IN CORRIDORS ONLY. MARYMOUNT HIGH SCHOOL . APPROX 2000SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50020	13041-20001-26816	4311 N FORMAN AVE	91602	4	165B177  1085	2424023011	RE11-1, H	South Valley				1431.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.14847	-118.35286	New Rooftop PV System for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50021	15041-10000-03629	432 S CURSON AVE TOWER 50-09F	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.0673	-118.35362	INSTALL (1) NEW 100 AMP PANEL & (4) NEW CIRCUITS	N	N	Express Permit	06/10/2024 12:00:00 AM
50022	10041-10000-15935	20750 W VENTURA BLVD	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	ADDRESS	34.16638	-118.58506	New Fire Alarm system for the office building. Plan check for power. (Plan was approved under# 10041-10000-14232, change the contractor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50023	15041-20000-08546	18248 W STRATHERN ST	91335	12	189B125   941	2102014044	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.21547	-118.53115	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 12kW (6+6). Ungrounded system.  (40) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50024	13041-20000-27477	1900 E SACRAMENTO ST	90021	14	123A217   242	5166020009	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.03044	-118.23387	T24 FOR EXISTING OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50025	16041-10000-38709	1506 N HAZELWOOD AVE	90041	14	156A221    73	5474013026	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Issued	11/01/2016 12:00:00 AM	ADDRESS	34.12337	-118.21473	PV2 roof mounted solar system installation to a single family home. Installing 8.2 central inverter along with 28 solar modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50026	12041-10000-22844	7342 N FULTON AVE	91605	2	186B157   361	2327001018	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	ADDRESS	34.20435	-118.42239	PLAN CHECK ONLY for T-24 Energy. All exit signs and emergency lightings are existing to remain. Permit to relocate light fixtures and add receptacles on existing branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50027	16041-20000-29604	1680 N VINE ST Suite 312	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for Title 24 only. Project site is an existing suite within a commercial building. Project scope is a tenant improvement. Total lighting area = 4,400 sq. ft.Note: Applicant has provided an Modification of Building Ordinaces Form that allows 90-minute battery back-up unit equipment to be used as emergency egress illumination. Modification was approved by Patrick Gilbert on 08-26-2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50028	13041-10000-16689	2801 W 6TH ST	90057	1	135A201   129	5155011001	C2-2	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	09/03/2013 12:00:00 AM	ADDRESS	34.06351	-118.28332	FA . change of occupancy of , and alterations to, an existing 4 -story building for use by a charter high school (Larchmont charter high school)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50029	19041-20000-29892	1501 N FIGUEROA ST	90744	15	036B201   484	7414001011	[Q]R2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	33.79256	-118.28229	T24 PLAN CHECK FOR EXISTING CHURCH BUILDING OUTDOOR PARKING LOT. LIGHTING ONLY. INSTALLING (11) OUTDOOR LED POLE LIGHTS. TOTAL SQUARE FOOTAGE = 33,456.52 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50030	16041-10001-27947	14006 W RIVERSIDE DR #228	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	09/29/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include replacing the track light fixture with a different type, adding lighting fixtures to the light floor plan, and revising title 24 calculations.Note: Permit is paid under PCIS#16041-10000-27947(((((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1525 SQ. FT. B#16016-10000-16565	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50031	15041-20000-35205	3644 S OVERLAND AVE	90034	5	120B161  1167	4314010077	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.02231	-118.40953	NEW 6 STORY 92 UNIT APARTMENT WITH 2500A 120/208 3PH-4W SERVICE.  VARIANCE TO SEPARATE FIRE ALARM PLANS HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50032	13041-20000-22293	3150 W SAN FERNANDO ROAD	90065	13	153B209   408	5458002013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.11582	-118.24713	Plan check for power and energy. Tenant Improvement. New 2000A Service. Existing fire alarm. NOT METHANE ZONE. Goodwill.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50033	19041-10001-38943	21255 W BURBANK BLVD SUITE 200	91367	3	174B105    87	2149019018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM			PC Approved	12/02/2019 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLAN CHECK FOR  ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS REVISIONS TO AN APPROVED FIRE ALARM SYSTEM, SCOPE OF WORK INCUDES ADDTIONAL DEVICES, CALCULATIONS HAVE BEEN UPDATED. NOTE ALL PERMIT FEES WILL BE UNDER 19041-10001-31975. NOTE THIS JOB WAS PREVISOULY SPLIT INTO THREE FLOORS. FIRST FLOOR IS UNDER 19041-10001-31975THE SECOND FLOOR IS UNDER  19041-10001-38943THE THIRD FLOOR IS UNDER 19041-10001-38944NOTE ALL CHANGES ARE CLOUDED UNDER DELTA 2. ---------ORGINAL WORK DESCRIPTION-----------THIS IS A PLAN CHECK ONLY FOR A TI TO AN EXISTING FIRE ALARM SYSTEM. SCOPE OF WORK IS ADDING DEVICES AND BATTERIES TO EXISITNG FIRE ALARM SYSTEM SPANNING THREE FLOORS. THIS IS THE SECOND FLOOR PORTION CONSISTING OF 98 DEVICES, AND TWO BATTERY. NOTE ALL FLOORS HAVE BEEN SEPARATED INTO THREE APPLICATIONS, ALL HAVE BEEN APPROVED BY FIRE. THE PERMIT FOR THE SECOND FLOOR HAS BEEN PULLED UNDER 19041-10000-31975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50034	16041-20000-06630	18722 W STRATHERN ST	91335	3	189B121   256	2103012013	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Expired	04/06/2018 12:00:00 AM	ADDRESS	34.21552	-118.54136	$0 permit fee due to State Senate Bill SB1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.4 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50035	16041-10001-22158	1318 E 7TH ST BLDG. B-1	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			PC Approved	01/12/2017 12:00:00 AM	ADDRESS	34.03608	-118.24052	THIS IS PLAN CHECK FOR EXISTING PERMIT. PLAN CHECK FOR FIRE PUMP CONNECTIONG TO EXISTING BUILDING DUE TO LOSS OF WATER PRESSURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50036	17041-10000-40558	10502 N ILEX AVE	91331	7	207B161   412	2620028031	[Q]M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.26077	-118.41785	REPLAVE INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50037	16041-10002-34072	21061 W SUPERIOR ST	91311	12	201B105   174	2746003004	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM			PC Approved	12/19/2016 12:00:00 AM	ADDRESS	34.24646	-118.59248	PLAN CHECK FOR REVISE IN INTERCONNECTION. CHANGES CLOUDED RED. THIS PLAN CHECK COVERS NEW MAIN BREAKER RATING AND POINT OF INTERCONNECTION COMPLIANCE. SEPARATE PERMIT WILL BE ISSUED FOR BUILDING LOAD RELOCATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50038	10041-10000-06718	1969 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	09/30/2010 12:00:00 AM	ADDRESS	34.06159	-118.20463	RENOVATION OF THE STORAGE AND FOOD PREPARATION AREA AT THE FOOD COURT/PLAZA CAFE AT THE USC HEALTH SCIENCE CAMPUS. THIS AREA IS COMMON TO OTHER FOOD TENANTS IN THE AREAPLAN CHK IS FOR TITLE . LIGHTING CONTROL PANEL IS EXISTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50039	15041-10000-33463	420 E CULVER BLVD	90293	11	096B149   175	4116010044	[Q]C4-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	33.961	-118.44556	NEW FIRE ALARM SYSTEM 68 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50040	11041-10000-04050	14006 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Closed	09/26/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	lOW RISE , TITLE 24 AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50041	17041-10000-23223	269 S WESTERN AVE 6-9	90004	4	135B193   204	5517001012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2115.00	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Info Complete	07/11/2017 12:00:00 AM	ADDRESS	34.06921	-118.30928	PC FOR RETAIL TI  FOR TITLE 24 ENRGY ONLY. INSTALLING NEW LIGHTS AND CONTROLS IN TENANT SPACES 6-9 (TOTAL OF 4)TOTAL AFFECTED AREA 2901 SQ.FT. NO BUILDING APPLICATION FOR THIS PROJECT, ALL EXISTING SPACES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50042	18041-20000-00928	10028 W MCBROOM ST	91040	7	207B181    66	2543010039	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.26358	-118.34876	Plan check for a PV1 roof-mounted PV system. System size is 11.45 kWac and consists of (1) inverter and (42) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50043	14041-10000-03315	1000 S GRAND AVE	90015	14	127-5A209 242	5139009008	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			02/05/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.04258	-118.26079	PLANCHECK FOR POWER AND ENERGY FOR A 273 UNIT APARTMENT.building p# 13010-10001-03605, 13010-10001-03605:7-story Mixed Use Building , 271 unit apt over 2 live/work unit & Retail (Shell only).  The building includes 5 stories of Type IIIA residential apartment on top of 2 stories on-grade Type IA  residential, retail, assembly, parking and 3 levels of Type IA subteranean parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50044	14041-10000-12647	6624 W ROMAINE ST PRKING-STRUCTURE	90038	4	144B185   969	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.08881	-118.334	NEW FIRE ALARM SYSTEM FOR PARKING STRUCTURE. 28 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50045	19041-20000-32416	2342-2350 S BEVERLY GLEN BLVD	90064	5	129B161   396	4315012002	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	10/01/2021 12:00:00 AM	ADDRESS	34.04745	-118.41781	800A 240/120V 1ph-3w service and meter board for small lot subdivision.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50046	19041-20000-48532	1918 S FOX HILLS DR	90025	5	132B157   692	4319011011	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.05683	-118.42002	Plan Check for PV-1, system size 11.47 KW, 32 Modules with P400 optimizers, (1) SE10000H inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50047	16041-20000-26638	21650 W OXNARD ST #2000	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check Title 24 only in existing high rise space. Total area: 4,184 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50048	15041-20000-43225	5716 N SUNNYSLOPE AVE	91401	2	174B157   327	2343014029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.17446	-118.42674	PV1 rooftop solar installation : system size: 10 kw(38) KU2656ZPA(1) SE10000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50049	14041-10000-06004	5308 N SEPULVEDA BLVD 1-36	91411	4	172-5A145  60	2250003023	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.16701	-118.46578	INSTALLATION OF A NEW FIREALARM SYSTEM FOR 36 UNIT APARTMENTS. FULLY SPRINKLERED. 2 PANELS AND 141 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50050	19041-10000-46025	12020 W CHANDLER BLVD	91607	2	171B165   117	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			Corrections Issued	05/14/2020 12:00:00 AM	ADDRESS	34.16825	-118.39512	PV2, NEW COMMERCIAL ROOFMOUNTED PV SYSTEM, SYSTEM SIZE IS 107.25 KWdc/100KWac. SCOPE OF WORK CONSISTS OF 330 MODULES (PHONO- SOLAR PS325P) LEADING TO TWO CENTRAL INVERTERS (TWO SOLECTRIA PVI-50TL). LEADING TO A SOLAR COMBINER PANEL WHICH IS INTERCONNECTED TO AN EXISTING 4000A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50051	17041-10000-09592	221 N FIGUEROA ST 16TH FLR	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.05882	-118.25099	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SPACE ON THE 16TH FLOOR. TOTAL AFFECTED AREA IS 3237 SQ. FT.  B#17016-10000-03342	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50052	17041-10000-16905	735 S FIGUEROA ST #303	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.04878	-118.26079	Title 24 plan check.  T.I. to existing Target store in suite #303.  New power poles, receptacles, and lighting.  New load < 400 amps.  Total area = 70,871 sq. ft.       Building permit #17016-20000-13245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50053	13041-20000-20005	15857 W LEMARSH ST	91343	12	204B141   532	2669004009	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.25561	-118.47829	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.2 KW USING 25 MODULES. 2 CENTRAL TRANSFORMERLESS INVERTERS. MORE THEN 2 STRINGS/INVERTER BACK ROOM PC. PERMIT TO INCLUDE SERVICE AND MAIN PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50054	18041-20001-23220	22641 W OXNARD ST	91367	3	177B097   482	2039017023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM			PC Approved	07/23/2018 12:00:00 AM	ADDRESS	34.17931	-118.62026	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 30.4 kWac and consists of (3) inverters, (91) modules, and (2) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50055	18041-20000-11326	718 S LOS ANGELES ST	90014	14	127-5A211 218	5145002002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.04275	-118.25081	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,860 sq. ft.Note: Building application has been generated under 18016-10000-09409	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50056	17041-10000-45118	10175 N SAN FERNANDO ROAD	91331	7	204B161   389	2623025030	C2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Issued	12/15/2017 12:00:00 AM	ADDRESS	34.2551	-118.41077	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50057	12041-10000-26632	11500 W OLYMPIC BLVD 6th FL	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			Corrections Issued	11/06/2012 12:00:00 AM	ADDRESS	34.03624	-118.44415	TENANT IMPROVEMENT IN EXISTING  FOUR SUITES, SAME TENANT, 6TH FLOOR PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50058	18041-20000-22127	13934 W HARTSOOK ST	91423	4	171B153   603	2269010005	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.16331	-118.43698	Plan check for a PV1 roof-mounted PV system. System rating is 11.527 kWac/12.73 kWdc consists of (1) 11.4 kWac rated inverter and (38) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50059	14041-10000-06744	3212 N BENDA ST	90068	4	157-5A183  37	5579036019	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			Reviewed by Supervisor	03/26/2014 12:00:00 AM	ADDRESS	34.1276	-118.34408	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(14) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50060	13041-10001-34458	1751 1/2 W 36TH PL	90018	8	120B193  1339	5041014037	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.02209	-118.31047	Expedited RSES plan checkper applicant request.{{PV1, Install a 2.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50061	18041-20000-42530	3831 S HUGHES AVE ste 102	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.02242	-118.39823	ti to an existing dental office.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50062	19041-10000-38419	11752 W TENNESSEE AVE	90064	11	123B149   701	4260029014	R1-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.03144	-118.4478	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(DR388H-US) WITH 12 MODULES USING P400 OPTIMIZERS AND ESS(TESLA POWERWALL) CONNECTED TO EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50063	17041-10001-34464	211 S AVENUE 20	90031	1	138A221   176	5447024033	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.07213	-118.22001	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.CHANGES TO APPROVED SET. ALL CHANGES ARE CLOUDED UNDER DELTA 3.SCOPE INCLUDES REVISING SINGLE LINE DIAGRAM, REMOVING/RELOCATING INVERTERS, RELOCATING MODULES, AND ADDING 54 MODULES. NEW SYSTEM SIZE  87.8KW DC /66.6KW ACTOTAL # OF MODULES 234 TOTAL # OF INVERTER 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50064	10041-20001-17824	5817-5835 N FIGUEROA ST	90042	1	151-5A229  93	5492012024	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.10	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.11051	-118.19129	"Supplemental from previously approved plans.  Add a new panel ""C"" as shown on plans for existing mezzanine lighting.  No changes in lighting.  Plan check for power only.  ****Plan check power and energy for TI of Dollar Tree. Existing 800A Service.*****"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50065	17041-30000-42276	4040 S DEL REY AVE	90292	11	108B149  1378	4230004022	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			11/21/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	33.98981	-118.44621	Plan check for power and energy 7-Story 228 Unit Mixed Use Apartment Building with 43 typical units. Total area: 161,386 sq ft. 4000A Service at 480VB#16041-10000-02510Fire alarm variance has NOT been File	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50066	19041-10000-19110	10811 W VANOWEN ST	91605	2	183B173   217	2466018047	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.19413	-118.36617	INSTALL (10) NEW FIRE ALARM DEVICES AND (1) COMMUNICATION PANEL ON EXISTING FIRE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50067	16041-20000-08597	240 W 118TH PL	90061	15	084B201   923	6087018005	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2414.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM	03/11/2016 12:00:00 AM		Permit Expired	04/12/2018 12:00:00 AM	ADDRESS	33.92546	-118.27758	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system. (13) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50068	14041-20001-10131	6028 S EILEEN AVE	90043	8	105B181   741	4004023007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	05/14/2014 12:00:00 AM	ADDRESS	33.98453	-118.34272	((expedite fees)))pv1 single family dwelling. total system size 3.8kw ac using transformerless inverter nonstandard plan. using power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50069	17041-10000-13680	9830 N RESEDA BLVD BLDG B	91324	12	201B125   137	2764001013	R3-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Apartment			04/26/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.24936	-118.53579	PC for 1 replaced FACP panel for fire alarm system in building B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50070	16041-10002-33650	3185 E WASHINGTON BLVD	90023	14	117A223    39	5169020003	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.01526	-118.21058	03/28/17Changes to an approved set of plans. Changes include reducing number of inverters, modules, revisig single line diagram and roof-layout. New total system size is 299.7KWac. (1118)Modules(614)Solaredge Power optimizers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50071	18041-10001-14971	227 N TIGERTAIL ROAD	90049	11	135B141   841	4403011026	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM			Reviewed by Supervisor	05/02/2018 12:00:00 AM	ADDRESS	34.06229	-118.47957	EXPREDITE PER APPLICANT REQUEST. (((PV1. INSTALL A NEW ROOF MOUNTED 5,360 DC W, PV SYSTEM WITH 16 PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50072	15041-20000-20237	6004 N DONNA AVE	91356	3	177B121   645	2156014046	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.17928	-118.54738	Plan check for PV roof mounted system. System size: 6.6kW with 26 microinverters and 26 modules. Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50073	14041-10000-02116	417 W PICO BLVD	90015	14	126A207   155	5139022015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.03928	-118.26478	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 6108  SQ FT. REPLACING TOTAL OF 6 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50074	12041-10001-07870	5700 W HOLLY OAK DR PV1	90068	4	151-5A191 153	5587013040	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2012 12:00:00 AM			Reviewed by Supervisor	05/31/2012 12:00:00 AM	ADDRESS	34.11006	-118.3137	PLAN CHECK FOR NEW INSTALLALLATION OF 5.89KW ROOF MOUNTED  PHOTOVOLTAIC SYSTEM. SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50075	14041-20000-20956	14148 W MAGNOLIA BLVD 2nd Floor	91423	4	171B153   452	2248022005	C1-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.16471	-118.44179	Convert existing office to medical office (Physical Therapy) on 2nd floor.  Install new  lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50076	14041-20001-04893	728 W WOODLAWN AVE	90291	11	108B149  1125	4237011001	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	33.99064	-118.45599	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 3 STRINGS/ INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50077	19041-10000-22903	19400 S HARBORGATE WAY BLDG B	90501	15	057B193   127	7351003011	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	33.85402	-118.30332	T-24 PLAN CHECK FOR A TI TO A WAREHOUSE (BUILDING B) GENERAL LIGHTING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 121,675 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50078	19041-20001-36622	22100 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.1863	-118.6083	Expedite per applicant request. Plan check for PV roof mounted system, System size: 33.06KW DC, 29.5KW AC with 76 PV Modules and 2 inverter(14.4KW )Applicant request: %%%%%%    Plan stay Van Nuys  %%%%%%%%Note: This is 12 buildings on 1 Plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50079	15041-20000-16489	8127 N JELLICO AVE	91325	12	189B129   106	2201001016	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.21819	-118.5177	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Microinverter system (standard plan used)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50080	14041-10000-19203	1925 S CENTURY PARK EAST #810	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Issued	07/23/2014 12:00:00 AM	ADDRESS	34.06066	-118.41426	Plan check for title 24 part 6 only.  Total area = 1,819 sq. ft.TI to existing commercial high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50081	19041-20000-18691	1875 CENTURY PARK EAST Unit K	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Issued	07/19/2019 12:00:00 AM	PIN	34.06139196	-118.41527843	Plan check for Title 24 only. Project site is an existing commercial tenant space in a high-rise building. Project scope is a tenant improvement. Total lighting area = 1,158 sq. ft.Note: Building application has been generated under 19016-20000-14778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50082	15041-20000-11451	16915 W NAPA ST	91325	12	195B133   507	2689018030	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Apartment			04/17/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	PIN	34.22705349	-118.50207694	redesign of pv system. new submittalPV2  COMMERCIAL ROOF TOP. TOTAL SYSTEM SIZE 21.4kw  AC. USING 2 CENTRAL TRANFORMED INVERTERS. total of 88 panels	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50083	16041-20000-22048	5750 W WILSHIRE BLVD FLR 1-6	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	RENOVATION OF EXISTING RESTROOMS BETWEEN FLOORS 1-6.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 10409.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50084	15041-10001-24151	11382 N BORDEN AVE	91331	7	213B161   916	2532007014	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.27702	-118.4092	EXPEDITED RSES PLAN CHECK PER APPLLICANT REQUEST.<<<PV 1 INSTALL 7.39 KW DC MOUNTED MICROINVERTER SOLAR SYSTEM. SINGLE FAMILY HOME. (29) MODULES TRIINA SOLAR 255 W (29) MICROINVERTER:ENPHASE  M215-60-2LL-S22-IG>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50085	17041-10000-27331	19600 S HAMILTON AVE	90502	15	057B201     4	7351033901	MR2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	33.85401	-118.28574	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY TOTAL 44850 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50086	19041-10001-36229	4145 N NOGALES DR	91356	3	165B121   407	2177007021	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.14684	-118.54961	Expediate fees for *********pc for pv-1 system. system size is 12.060KW. system consists of (34) modules (AXITEC AC-385MH/144S) with (34) P400 optimizers. (1) 11400 inverter.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50087	15041-20000-26399	11501 W DUQUE DR	91604	2	156B169   116	2381022002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.12715	-118.38472	Installation of new roof mounted solar PV array.  Total system size = 11.07 kW.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50088	14041-20000-23042	3783 S WADE ST	90066	11	111B153   436	4246032041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.00201	-118.43856	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTERS. USING STANDARD PLAN. TOTAL OF 20 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50089	15041-10000-05986	1277 S WESTERN AVE	90019	10	129B193  1281	5080005020	C4-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	PIN	34.0473965	-118.30939984	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 468.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50090	18041-20000-10393	1660 W 3RD ST	90017	1	133-5A205 190	5153008017	C2-1	Central	Westlake	Westlake North		2091.04	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.06052	-118.26744	MEDICAL CLINIC TI WITH CRITICAL CARE PATIENT AREAS.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50091	18041-10000-33314	522 W VERNON AVE	90037	9	112-5A201  72	5018033017	C2-1	South Los Angeles	South Los Angeles	Voices		2321.20	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.00355	-118.28356	New Fire Alarm System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50092	14041-20000-14070	4228 N ALHAMA DR	91364	3	165A107   120	2172016062	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.14745	-118.59268	Roof mounted PV system with Enphase microinverter, model number M215-60-2LL.  PV system size 3.24KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50093	10041-20000-25039	21044 W SHERMAN WAY	91303	3	183B105   227	2112030002	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.20085	-118.59206	energy plan chek 320 square feet stairways	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50094	16041-10000-29280	2300 W BEVERLY BLVD 1-49	90057	13	136-5A205 272	5154010034	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.06761	-118.27314	NEW 45 UNIT APARTMENT. NEW 1600A SERVICE. PC FOR POWER AND ENERGY. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50095	17041-10000-01514	13540-13546 W DESMOND ST	91331	7	210B157    70	2523005007	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.27544	-118.42731	PC FOR POWER. SERVICE UPGRADE FOR A INDUSTRIAL BUILDING FROM 200A TO 5000A. THE PLAN INCLUDES TWO BUILDINGS, WHICH MAIN SERVICE FEEDS BOTH OF THEM. THE SECOND BUILDING ADDRESS IS 13546 DESMOND ST WITH APPLICATION 17041-10000-01519THE PLAN INCLUDES BOTH BUILDING  DRAWINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50096	13041-10001-34233	12130 N BELLANDO CT	91344	12	219B125    91	2601073020	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.29435	-118.52546	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STD PLAN. 8KW DC .(32) SOLARWORLD 250W BLK(32) ENPHASE M215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50097	17041-20000-46359	1300 N WESTERN AVE	90027	13	147A193   247	5544031023	C2-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM	02/21/2019 12:00:00 AM		Issued	02/21/2019 12:00:00 AM	ADDRESS	34.09512	-118.30901	"Plan check for power and energy. Remodel to convert (E)service station to retail (7-Eleven), including replacing storefront and to add 16' x 29'-6"" extension. New lighting for (E) gas station canopy. New 800A 120/240V 3ph 4w service. T24 area: indoor-2,236sqft; outdoor-10,688sqft."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50098	19041-10000-05447	1540 S HAYWORTH AVE	90035	10	129B173   952	5068021017	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			02/14/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	07/31/2020 12:00:00 AM	ADDRESS	34.04858	-118.3682	Full plan check for a new 8 units, 3 story apartment builing over 1-level of subterranean garage. Scope includes a 800-Amp 3-phase 4-wire 120/240v with (2) typical unit panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50099	14041-10000-18521	16304 S VERMONT AVE	90247	15	069B197   333	6120018084	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Apartment			07/09/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.88328	-118.29117	FA FOR NEW APT BLDG. 194 devices and new panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50100	17041-10001-20104	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.07666	-118.3805	SEE APPLICATION NOTES*****PC FOR A LOST SET.  (((Plan check for power only.  Installation of new distribution board, UPS, and two subpanels in existing Cedars Sinai building.  New HVAC and data rack loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50101	10041-20000-00136	12669 N ENCINITAS AVE	91342	7	219B141    70	2604035022	[Q]CM-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM	01/22/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.29989	-118.47409	office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50102	16041-10000-44957	9325-9329 W PICO BLVD	90035	5	132A167   206	4330035014	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			Re-Activate Permit	04/29/2020 12:00:00 AM	ADDRESS	34.05542	-118.39361	PC FOR PV2 COMMERCIAL ROOFTOP SOLAR. SYSTEM SIZE IS 20KA AC USING CENTRAL INVERTER SYSTEM WITH TOTAL OF 57 MODULES AND POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50103	14041-10001-11584	8 S CHESTER PL Bldg 8 1/2	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM			PC Info Complete	04/25/2017 12:00:00 AM	ADDRESS	34.03102	-118.27718	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE REVISED CONNECTION OF MAIN SERVICE AND DISTRIBUTION TO EXISTING PANELS. PROVIDING 2 NEW SUBPANELS AND 1 TRANSFORMER. PROVIDING NEW ENGINEER ON RECORD TO APPROVE THE CHANGES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50104	14041-20001-11822	415 S WINDSOR BLVD	90020	4	135B189   465	5505027008	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.06653	-118.32159	PV1.  Install 6 kW roof-moutned PV system, interconnect with main service panel.  (24) modules w/ (24) microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50105	18041-10001-45785	11830 N PORTER VALLEY DR	91326	12	216B117   223	2822008005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.28675	-118.55351	SUPPLEMENT TO AN APPROVED SET FOR PV . SCOPE INCLUDES ADDING 1 SUB PANEL ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50106	18041-10000-02882	10250 W SANTA MONICA BLVD LL1600	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for fisrt time tenant ""Petros's Speakeasy"" ste.# LL1600. Installing (2) new panels, (1) 30 KVA xfrm, new lights and receptacles."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50107	13041-10000-03517	3501 S WATT WAY	90089	8	120A201    44	5039012030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Closed	01/29/2014 12:00:00 AM	ADDRESS	34.02243	-118.28658	Temporary power for constuction the renovation of the  USC Heritage Hall. 4160 MV unit substation will provide power to distribution panels. Modification to allow multiple feeders entering existing building to supply panel,  equipment, and trailer during construction has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50108	17041-10000-07497	1509 S 4TH AVE	90019	10	126B189    71	5072024002	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.0451	-118.32156	PV INSTALL NEW 2.7 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A COMMERCIAL BUILDING.(8) MODULES: SOLARWORLD 340W MONO (1) INVERTER: SOLAREDGE 3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50109	13041-10000-04528	3500 N VISTA HAVEN ROAD	91403	5	159B145   335	2279011006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.1332	-118.4699	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. USING 35 MODULES, 5 STRINGS, NON STANDARD PLAN. TOTAL SYSTEM SIZE 11.44KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50110	14041-20000-10967	15715 W MARILLA ST	91343	12	201B141   320	2671005002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Expired	07/08/2016 12:00:00 AM	ADDRESS	34.24749	-118.47439	Roof mounted PV system with Optimizers and transformerless inverters,  system size 9KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50111	15041-10000-34266	928 S BROADWAY	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Closed	06/24/2020 12:00:00 AM	ADDRESS	34.04154	-118.25658	600A TEMPORARY CONST SERVICE EQUIPMENT TO SUPPLY CRANE, MANLIFT AND TRAILERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50112	19041-10000-45848	4000 W SLAUSON AVE	90043	8	108B181   242	4019001025	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	33.98876	-118.3441	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50113	16041-20001-31370	300 N VIA NICOLAS	90272	11	126B117   124	4416002015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM			PC Approved	09/14/2016 12:00:00 AM	ADDRESS	34.044	-118.55426	Expedited plan check fee per applicant request.PV1.  Install 19.32 kW DC roof mounted PV system.  (E) 600 A service.  (56) modules with (2) 7.7kW rated central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50114	13041-20001-31720	19600 W WELLS DR PV1	91356	3	171B117   372	2175011004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2013 12:00:00 AM			Reviewed by Supervisor	11/15/2013 12:00:00 AM	ADDRESS	34.16395	-118.56074	EXPEDITE FEES ONLY.           <<<PV System for a new single family dwelling using Enphase M215.  Rooftop>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50115	17041-20002-03041	8800 S HOOVER ST	90044	8	096A201    80	6038013900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	33.95787	-118.28682	Partial renovation of community pool and pool house.  800A 240/120V 3ph-4w service replacement.  Plan check for power. Title 24 Part 6 plan review under original master permit.(((New outdoor lighting for pool facilities and interior lighting for pool house pump rooms and lifeguard room.  Plan check for energy.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50116	17041-10000-21997	380-384 WORLD WAY AOA-Lighting	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	11/17/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR MEDUIM VOLTAGE LIGHTS (SERIES CONNECTED) FOR  LAXINSTALLING NEW AIR FIELD TAXI LIGHTS WITH NEW LIGHTS AND CONUITS. BL#16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50117	12041-10000-01355	1032 S CRENSHAW BLVD C-2	90019	10	129B189    73	5081004024	C2-1-O	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.0536	-118.32335	"NEW ""AROMA FOOT MASSAGE"" IN SUITE C-2.  PLAN CHECK FOR POWER ONLY.  T-24 MAY BE REQUIRED.    APPLICANT IS REQUESTING PLAN CHECK."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50118	19041-20000-20987	2049 S CENTURY PARK EAST 38th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Power and lighting for new catering kitchen in commercial office tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50119	13041-10000-09794	6934 N LARAMIE AVE	91306	3	183B113   531	2135033018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.19665	-118.57304	6.86 KW DC PV1, roof-mounted single-story house.  {28 modules: YingLi YL245P-29B} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50120	18041-20000-07650	5711 N SEPULVEDA BLVD	91411	4	174B145   884	2260010017	CM-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.17435	-118.4665	"""0$ permit fees due to senate bill 1222, ab 1414""PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 240KVA CONSISTING OF 4 INVERTERS(CHINT SCA60KTL-DO/US-480) AND 1064 MODULES(CSUN320-72P) ON 600A LOAD CENTER"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50121	19041-20000-42150	14544 W VANOWEN ST	91405	6	180B149    43	2236009018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.19371	-118.45032	Power and lighting for new restroom.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50122	10041-10000-16839	10654 N BALBOA BLVD	91344	12	207B133   586	2684001023	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Public Safety Only			08/25/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.26387	-118.50206	NEW FIRE WARNING SYSTEM WITH MONITORING OF SPRINKLER SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50123	17041-10001-14296	3820 E UNION PACIFIC AVE	90023	14	117A229     8	5192001001	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.01638	-118.19256	PLAN CHECKING CHANGES TO APPROVE SET OF PLANS. NEW CONDUIT ROUTING. PULLBOX RATED 5000A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50124	17041-10000-33624	8717 N WHITAKER AVE	91343	12	195B133   426	2688041003	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.22912	-118.49945	PC for rooftop solar for SFD. Installing 26 new modules with optimizers and new 5kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50125	18041-20000-26209	5059 W PICO BLVD	90019	10	129B181   941	5070006012	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.04808	-118.34826	Plan check for Title 24 only in existing space offce T.I. Total area: 3857 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50126	16041-10000-15637	9024 N TELFAIR AVE	91352	6	195B165   883	2631021031	(T)(Q)R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.23323	-118.39319	PV1 installation to a single family home. Inverter: 4.2 kw, (21) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50127	18041-10000-25818	320 N MADISON AVE	90004	13	138B197   191	5501002032	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	07/21/2020 12:00:00 AM	ADDRESS	34.07708	-118.28902	NEW FIRE ALARM SYSTEM IN THE BUILDING WITH 460 DEVICES.BLDG PERMIT: 17010-10000-01411	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50128	18041-20000-38686	1025 S LA BREA AVE	90019	10	132B181   842	5084014027	C2-1	Central	Wilshire	P.I.C.O.		2162.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Info Complete	07/02/2019 12:00:00 AM	ADDRESS	34.05621	-118.34528	Plan check for power and energy. Project site is a new 2-story commercial building; 1st floor restaurant with 2nd floor dental office. Work includes a 400-amp service and a total lighting area of 3,664 sq. ft.Note: Building application has been generated under 18010-20000-03909	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50129	17041-20000-05462	6646 N BECK AVE laundry rm	91606	2	180B169   394	2320023004	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Apartment			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.19159	-118.38327	plan check for roof mounted pv system sized 0.5kw interconnected with laundry room panel.Partial permit fees paid under application number 16041-20000-32785.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50130	14041-10000-08935	9463 N BEACHY AVE	91331	6	198B157   224	2642017028	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Expired	05/06/2016 12:00:00 AM	ADDRESS	34.24176	-118.43178	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50131	14041-10000-07906	11562 W MORRISON ST	91601	2	168B169    91	2354006024	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			Reviewed by Supervisor	04/09/2014 12:00:00 AM	ADDRESS	34.16023	-118.38429	PV1,INSTALL 13.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U(54) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50132	16041-20000-17691	13075 W VICTORY BLVD	91401	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.18684	-118.41708	PLAN CHECK FOR POWER ONLY CORE AND SHELL IN EXISTING BUILDING. NEW 800A SERVICE AND 14 NEW CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50133	16041-10001-33896	555 S FLOWER ST 28th & 29t	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for Title 24 only in existing space high-rise Building T.I. Total area: 1,650 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50134	12041-10000-08632	4775 S BROADWAY	90037	9	111A203   100	5110015013	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	33.99939	-118.27853	New fire alarm panel with new devices on the 1st floor and replacement of devices on the 2nd and 3rd floors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50135	15041-20000-11900	8920 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.23117	-118.36753	Plan check for power and Title-24 (energy).  Total area = 14,355 sq. ft.T.I. to existing grocery store.  Space was vacant for several years previously.  New distribution equipment connected to existing landlord switchgear.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50136	16041-10000-32361	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	FULL PC FOR POWER AND ENERGY FOR AN EXISTING MEDICAL OFFICE AT LEVEL 3. SCOPE INCLUDES NEW LIGHTS AND ADDING RECEPTACLES FOR AN OFFICE, AND DRUG TESTING SPACE. PC IS FOR OFFICE SPACE/TESTING SPACE, NON INVASIVE PROCEDURES. TOTAL AFFECTED AREA IS 901 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50137	15041-20000-24414	18434 W VANOWEN ST	91335	3	180B125    16	2125014016	[Q]C2-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM			PC Info Complete	01/05/2016 12:00:00 AM	ADDRESS	34.19372	-118.53488	Plan check for power and energy. New commercial building (restaurant). Adding new lighting (indoor and outdoor) including emergency. New service. Outdoor dining. Outdoor open parking lot. Total sqft. 6,929 for indoor 24,000 outdoor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50138	11041-20000-18731	11001 N SEPULVEDA BLVD 1st floor	91345	7	210B145   300	2664012031	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1093.00	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM	01/18/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.2697	-118.4673	General radiology suite, rooms 10022, and 10021, and support rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50139	17041-10000-45718	9140 N VAN NUYS BLVD	91402	6	198B149   492	2639008056	(Q)P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.23662	-118.45005	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50140	13041-10000-21137	12652 W VILLAGE LANE bldg #1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50141	14041-10000-13882	1503 W OAK GROVE DR	90041	14	159A227    48	5689029018	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.13139	-118.19877	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50142	18041-20001-36970	12915 N TITIAN AVE	91344	12	222B133   260	2602016004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.30518	-118.50684	Removal of MSP upgrade from project scope.  Interconnecting PV system to (E) 100A MSP.  (((Plan check for PV roof mounted system, system size: 5.12KW DC, 4.574KW AC with 16 PV Modules and 16 Microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50143	14041-20002-29059	3541 N WESTFALL DR	91436	5	159B137    92	2293008005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	ADDRESS	34.13539	-118.49314	RECHECK FOR RELOCATION OF EQUIPMENT. NO CHANGE IN SYSTEM DESIGN. RESTAMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50144	19041-20002-02910	12322 W HESBY ST	91607	2	171B165   966	2356024003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM			PC Approved	02/07/2019 12:00:00 AM	ADDRESS	34.16215	-118.40179	Expedite fee forpc for pv system. system size is 14.04KW(DC)-12.771KW(AC). 39 modules model LG360Q1C. 39 enphase micro inverter iq7plus. 1enphase Iq combiner	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50145	19041-20001-20607	13109 W NIMROD PL	90049	11	129B137   285	4407011010	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	34.05111	-118.49541	PLAN CHECK ONLY, SUPPLEMENTAL, CHANGE TO APPROVED SET. CHANGE IN FIRE SETBACK ON ROOF LAYOUT PAGE. CLOUDED CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50146	12041-10000-12935	14850 W VICTORY BLVD	91411	6	180B149   867	2241001029	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	01/07/2013 12:00:00 AM	ADDRESS	34.18643	-118.45707	T.I. to an existing McDonald's.  Lighting changes, new circuits, and equipment.  Occupancy load is 93 people.  FULL Plan check for Power and Energy is requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50147	13041-10000-08156	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	RENOVATION OF INTERIOR CORRIDOR WIRING AND LIGHTING. RELOCATION OF SPACE. TOTAL AREA 385 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50148	18041-20000-40579	17911 W MONTAGUE CT	91344	12	219B129   253	2601063013	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.2984	-118.52477	pv1install roof mounted pv system sized 6.9KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50149	16041-10000-03181	18330 W OXNARD ST	91356	3	177B125   692	2157002131	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.18002	-118.53198	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 4980	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50150	14041-10001-21086	13031 W JEFFERSON BLVD #300	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM			Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	33.97451	-118.42531	REVISIONS TO PERMITTED SET OF PLANS;ABOUT 300KVA ADDED LOADS. EP3UPS panel updated to 600A.PC FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT OF (E) OFFICE BUILDING : NEW NON-BEARING PARTITION WALLS , NEW CEILING PANELS , NEW MILLWORK , FINISHES . TOTAL AREA  21190 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50151	16041-10000-19862	4907 S WALL ST	90011	9	111A205   250	5109004003	RD2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.99812	-118.27194	PV1 rooftop solar 3kW AC system.   (8) KU2656ZPA   (1) PVI-3.0-OUTD	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50152	13041-20000-20164	15503 W VENTURA BLVD STE 220	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.15504	-118.4723	Plan check for energy and emergency lighting. Low rise commercial, Office spaces. 2nd floor, suite 220. Asylum Entertainment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50153	10041-10000-04720	3504 W SUNSET BLVD	90026	13	144A203   217	5427025009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	05/03/2010 12:00:00 AM	ADDRESS	34.08874	-118.27673	First time tenant for a new SUBWAY. one story, new 200 amps panel , power and enegy.  According to the applicant the 1200 Amp is existing to be verified by the inspector. THE 1200 AMP SERVICE MAY REQUIRE COMPLETE PLAN CHECK AND PERMIT SUBJECT TO FIELD INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50154	12041-10001-18676	2206 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	ADDRESS	34.03796	-118.44083	MODIFICATIONS TO APPROVED SET OF PLANSUNDER APPLICATION NUMBER# 12041-10000-18676ADDITION OF PENDANT LIGHTS AND RECESSED DOWN LIGHTS.***********************************************************************************TENANT IMPROVEMENT TO EXISTING TAKE-OUT RESTAURANT.  Load is less than 400 Amps.  Change to lighting and receptacles.  PLAN CHECK ONLY for Energy, All emergency lighting is existing and Not a part of this plan check per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50155	19041-10001-43544	5825 W SANTA MONICA BLVD	90038	13	144B189   595	5534017022	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.09089	-118.31662	ROOF TOP SOLAR PLAN CHECK FOR 22.8KWac (26.478 KW CEC AC) (29.7 KWdc) USING 90 AXITEC-AC-330P/156-72S MODULES, 90 SOLAREDGE P400 OPTIMIZERS, AND 2 SOLAREDGE SE11400H-US INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50156	18041-20001-43411	4625 N SANTA LUCIA DR	91364	3	166-5A105  67	2171009065	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.1517	-118.60416	11/26/2018 Changes to an approved set of plans. Micro-inverter manufacturer and model has changed. PV module has remained the same. System size is now 15.84 kWdc/14.26 kWac-CEC.*****Previous Work Description*****PV1.  Install 15.84 kW roof mounted grid tied PV system.  (44) modules with microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50157	17041-10000-02643	10700 W SANTA MONICA BLVD #130	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.05167	-118.432	Plan check for Title 24 only in existing space. T.I. Total area: 1220 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50158	15041-20001-38556	20790 W NORDHOFF ST #4	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Issued	02/24/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	02/24/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Changes have been made to reflect on-field installation. Additional equipment has been installed to allow the disaggregated measurement of electrical load.*****Previous Work Description*****PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT. (THE SHELL WAS BUILD FOR RETAIL PUROSE). TOTAL AREA 1254 SQ FT.B# 15016-10000-23306	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50159	19041-10000-35977	13389 N WHEELER AVE	91342	7	225B157   395	2510001013	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Issued	09/10/2019 12:00:00 AM	ADDRESS	34.31447	-118.43089	PC FOR PV-1. SYSTEM SIZE 7.125 KW. 25 MODULES (HANWHA Q-CELL. QPLUS BFR-G4.1) WITH P320 OPTIMIZERS. 1 CENTRAL INVERTER (SE5000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50160	16041-10000-38517	10910 W KINROSS AVE	90024	5	132B149    98	4363023027	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.06033	-118.44604	PC FOR POWER ONLY. SCOPE INCLUDES UPGRADING AN EXISTING SERVICE TO 1600A, AND REPLACING SUBPANELS. SERVICE IS FOR A MULTI-TENENT COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50161	16041-10004-42610	695 S SANTA FE AVE	90021	14	124-5A2171363	5164019026	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.03508	-118.23039	CHANGES TO AN APPROVED SET OF PLANS. CHANGES ARE UNDER BULLETIN 18 & 19 AND DELTA U & T.  CHANGES INCLUDE ADDING BATTERY BACKS TO STAIRWAYS WITH EMERGENCY INVERTER. REVISING TITLE 24 CALCS, AND REVISING PANEL SCHEDULES. NOTE: PERMIT IS PAID UNDER PCIS 16041-10000-42610	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50162	11041-10000-18401	770 W WILSHIRE BLVD 7TH FL	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			PC Approved	08/30/2011 12:00:00 AM	ADDRESS	34.04914	-118.25811	TENANT IMPROVEMENTS IN THE ELEVATOR LOBBY AND REST ROOMS AND ADDING WIRED OFFICE  FURNITURE USING EXISTING BRANCH CIRCUITSPLAN CHK ONLY FOR TITLE 24 AND 1 EA EMERGENCY CKT;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50163	11041-10000-17130	4501 W MARTIN LUTHER KING, JR BLVD	90016	10	117B181   239	5046034014	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/12/2011 12:00:00 AM	PIN	34.01808559	-118.34594619	TI TO AN EXISTING 7-ELEVEN.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50164	15041-20003-06350	6320 N TOPANGA CANYON BLVD G-1690	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	8.17.2015 - Changes to approved set. Delta 4 changes only. Add 2 inverters to supply emergency power to EM-designated recessed LED lights in dining area. Add occupancy sensors for lighting in corridors (to satisfy partial-on control requirement).[08/13/15 Changes to an approved set of plans. Delta 3 changes. Changes to the location of area controls and rewiring of some circuits.  (((Plan check for power and Title 24 (energy).  Total area = 6,575 sq. ft.T.I. to (new) Wokcano restaraunt.  First time tenant.  3 new panels, 1 1125 KVA transformer, and lighting + equipment loads.)))]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50165	19041-20001-21361	12326 N FINCH CT	91326	12	219B109   533	2701102023	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	ADDRESS	34.29608	-118.58212	CHANGE OF ADDRESS TO 12326 N FINCH ST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50166	13041-10001-30871	15822 W CHATSWORTH ST	91344	12	207B141   422	2668001016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.26442	-118.47705	Expedited RSES plan check per applicant request. (((PV1, Install5.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 21 modules Yingli Yl245P-29b.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50167	17041-10000-15539	5359 W ADAMS BLVD	90016	10	123B177   926	5043002002	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.03265	-118.35992	PC FOR POWER AND ENERGY.  UPGRADE SERVICE TO 800A 120/240 3PH/4W SCOPE INCLUDES 4 UNIT RESEDINTIAL WITH 2 RESTAURANT SPACES, IN A MIXED USE BUILDING. B# 17014-10000-01929	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50168	12041-10000-19891	920 W BLOOM WALK 7th Floor	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.01996	-118.28938	Remodel of an existing lecture and laboratory area on the 7th floor at USC.  (Seaver Science Building.)  Place of assembly, Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50169	13041-10000-30446	11550 N GLENOAKS BLVD	91331	7	213B161   564	2524012024	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.27993	-118.41801	TENANT IMPROVEMENT FOR 7-ELEVEN. PLAN CHECK IS FOR POWER AND ENERGY . EXISTING 800A SERVICE.  TOTAL ILLUMINATED AREA IS 12555 (INDOOR + OUTDOOR) . ADDITIONS OF 5 PANEL BOARDS AND CKTS. CORE AND SHELL SUBMITTED UNDER 13041-10000-16128; APPROVAL PENDING, AS OF 10/30/13.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50170	12041-20000-24853	3387 S LIVONIA AVE	90034	10	120B165    26	4312013025	M1-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.02894	-118.39314	Removing a mezzanine and installing light fixtures in an existing commercial building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50171	14041-20001-00051	20636 W AETNA ST	91367	3	177B109     2	2149010044	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.17872	-118.58307	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50172	13041-20000-29229	2180 S WESTWOOD BLVD SUITE 2C	90025	5	126B157   253	4321012071	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	12/14/2013 12:00:00 AM	ADDRESS	34.04421	-118.4318	PC FOR POWER AND ENERGY FOR MEDICAL. DENTAL OFFICE REMODEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50173	11041-10000-20186	10320 W OLYMPIC BLVD	90064	5	129B161   103	4315018057	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	10/03/2011 12:00:00 AM	ADDRESS	34.0522	-118.41724	T.I. to an existing hotel lobby.  Plan Check ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50174	10041-20000-20621	355 S GRAND AVE 15TH FLR	90071	9	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	11/05/2010 12:00:00 AM		Permit Finaled	09/14/2011 12:00:00 AM	ADDRESS	34.05191	-118.2525	Plan check T24 Energy general/emergency lighting for office TI on the 15th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50175	18041-10000-11379	355 S GRAND AVE 5TH FL	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	TENANT IMPROVEMENTS IN OPEN OFFICES /STORAGE ROOMS / CORRIDORSPLAN CHECK IS FOR TITLE 24 AND 1 EAQ EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50176	10041-20001-15167	1870 S VETERAN AVE	90025	5	129B153   821	4323007***	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM			PC Approved	12/20/2010 12:00:00 AM	ADDRESS	34.04744	-118.43865	Plan check only. Revise T24 energy calculations and to indicate exit signs and emergency lighting are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50177	17041-20001-05566	16047 W LONDELIUS ST	91343	12	195B141   602	2672025018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.22948	-118.48209	Expedite feePV1.  Install 8.505 kW roof mounted grid tied PV system.  (27) modules with (2) 5.2 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50178	19041-30000-17475	864 N SWARTHMORE AVE	90272	11	129B125   668	4412002016	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	34.04658	-118.52587	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/addition of lighting to sales floor. Total lighting area = 18,215 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50179	13041-10000-33243	338 S WESTERN AVE STE C	90020	10	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.06777	-118.30889	PLAN CHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR FOOT MASSAGE.  2 STORIES, SUITE C. 925 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50180	14041-20000-32087	19203 W CANTARA ST	91335	3	192B117   821	2104001019	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.21937	-118.5514	PV1Install a roof-mounted solar array on SFD. interconnect with 200A MSP.System size: 4.2kW. Ungrounded system.15 327W pv modules across two strings (7+8).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50181	11041-20000-21068	6267 W OLYMPIC BLVD	90048	5	132B173   391	5088019017	[Q]R3-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			10/03/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	12/15/2011 12:00:00 AM	ADDRESS	34.05877	-118.3675	Plan check for roof mounted 4.6KW Photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50182	17041-10000-45189	6806 S LA TIJERA BLVD	90045	11	102B173   108	4103002025	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	01/02/2020 12:00:00 AM		Issued	01/02/2020 12:00:00 AM	ADDRESS	33.97705	-118.37181	EXISTING BUILDING WITH 4 EA TENANT SPACES EACH PROVIDED WITH MINIMUM LIGHTING  AND POWER CIRCUITS PRIOR TO TENANTS OCCUPING THE COMMERCIAL SPACES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50183	19041-20000-02009	11415 N LEMONCREST AVE	91342	7	213B177   208	2529008028	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.27684	-118.35741	Plan check for PV roof mounted system, system size: 12.675KW with 39 PV Modules and 2 inverters(5.2KW and 7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50184	19041-20001-17259	13801 W VENTURA BLVD	91423	4	165B153   543	2271017005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.14852	-118.43319	5/22/2019changes to an approved set of plans.  changes to relocate and install combinational exit/egress lighting.this is plan check only.  ((((T24 ONLY PLAN CHECK. TI TO EXISTING LOW RISE COMMERCIAL BUILDING. LIGHTS AND OUTLETS ONLY ON EXISTING BRANCH CIRCUITS. TOTAL SQUARE FOOTAGE = 1204SF))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50185	17041-20000-34235	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	10/07/2018 12:00:00 AM	ADDRESS	33.76094	-118.29308	replace existing outdoor luminaires with new led.  plan check for outdoor energy only.  total square footage 205000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50186	15041-20000-20644	500 N TOYOPA DR	90272	11	123B129    83	4411015001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.03665	-118.51973	Plan check for new single family dwelling. Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50187	15041-10002-25611	15232 W FOOTHILL BLVD Unit 151	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.32292	-118.46695	RELOCATION OF PV EQUIPMENT IN THE GARAGE.  THIS IS PLAN CHECK ONLY.  PV1, INSTALL 3.92 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(12) MODULES: SUNPOWER SPR327NE(1) INVERTER: ABB PVI-3.8-OUTD-US-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50188	10041-10000-01531	3335 S FIGUEROA ST SUITE-UGY-4	90007	8	120A203   177	5123009027	(T)(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM	04/01/2010 12:00:00 AM		Permit Finaled	09/17/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	First time tenant for a yogurt shop.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50189	13041-10000-34871	1001 S BROXTON AVE	90024	5	135B149   609	4363024012	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.06222	-118.44712	"T24 PART 6 ENERGY TO (E) COMMERCIAL BUILDING (""CALIFORNIA PIZZA KITCHEN"") ."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50190	13041-10001-35781	2403 W 4TH ST	90057	1	135A203   203	5154035003	R3-1	Central	Westlake		YES	2088.02	Electrical	Electrical	Apartment			12/23/2013 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.06409	-118.27662	EXPEDITED PER APPLICANTS REQUEST.PV2. APARTMENTS  ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19.2 KW DC. CENTRAL INVERTER.(64) RENESOLA JC300(2) SMA SB6000US(1) SMA SB7000US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50191	12041-10000-20762	1520-1520 1/2 S WESTERN AVE	90732	15	012B193   434	7560013045	R2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	33.72974	-118.31291	Plan check for 11KW roof mounted photovoltaic system. 2-family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50192	14041-20000-03568	10965 N GAZETTE AVE	91311	12	210B109   200	2706026010	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.26953	-118.58802	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.4 KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50193	15041-10001-04927	16826 W MONTE HERMOSO DR	90272	11	138B117   398	4431030003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM			Verifications in Progress	03/19/2015 12:00:00 AM	ADDRESS	34.07076	-118.55439	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  (2 inverters with a total of 5 strings)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50194	16041-20000-41474	1447 N MARTEL AVE SLS#4	90046		147B181  1153	5550021013							Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Plans on Hold	12/02/2016 12:00:00 AM	ADDRESS	34.09728	-118.35102	New 4-story single family dwelling with subterranean attached garage.  Small lot subdivision.  Collective service for (6) new SFDs on same lot.  Plan check for power and energy.  Service equipment, house panel, and energy fees charged on unit #1.  Building permit filed under 16010-10000-02540 et al	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50195	15041-20000-35058	11550 W VALERIO ST	91605	2	186B169   712	2316028014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.20472	-118.38421	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:  3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50196	14041-20002-04891	14006 W RIVERSIDE DR #270	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	4/28/2015 Changes to an approved set of plans. Changes include the relocation of receptacle circuits, lighting circuits, and a revised lighting floor plan. All changes have been clouded and marked as Delta A2.*****Previous Work Description*****Change to approve set of plan. Replace the light fixture in the plan to match it in the field. (((((((T.I. to existing building Space #270. Install general/emergency lighting. Plan check for energy only.Note: Permit is under a separate application))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50197	15041-20000-38296	5437 N LUBAO AVE	91364	3	174B113   541	2164003017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.16938	-118.56707	$0 permit fee due to State Senate Bill SB-1222. PV1, 18.98 kW system, roof mounted solar array.  (73)modules: Canadian Solar CS6P-260P   (2)inverters: FRONIUS   PRIMO 8.2-1	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50198	17041-20002-18438	22801 W ROSCOE BLVD Bldg. 2	91304	12	192B097   578	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.22014	-118.62547	06-01-2018 Changes to an approved set of plan. Changes include relocate load to panel 2HM. All changes has been clouded as delta 9.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50199	15041-20000-33525	1601 E 103RD ST #9	90002	15	091-5A213 176	6048013927	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	33.94385	-118.24586	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 1,105 sq. ft.Note: Building application has been filed under 15016-10000-20554	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50200	13041-20000-05139	6731 N FALLBROOK AVE	91307	3	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.19189	-118.62364	Remodel 7 theaters and associated support areas.  Assembly areas, full plan check required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50201	15041-20000-10561	9850 N TEXHOMA AVE	91325	12	201B129    86	2755011008	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.24999	-118.51709	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50202	17041-10000-28423	8541 N LEHIGH AVE	91352	6	192B173   210	2408016005	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.22477	-118.36882	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.92KWac.(31)MODULES-SUNPOWER SPR-X21	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50203	16041-10000-22117	2239 S VETERAN AVE	90064	5	126B153   659	4322011016	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Expired	07/30/2018 12:00:00 AM	ADDRESS	34.04114	-118.4336	PC FOR ADDITION TO EXISTING PV SYSTEM. TOTAL ADDITION 3KW AC USING 9 MODULES. NEW SUBPANEL ADDED TO COMBINE TOTAL PV OUTPUT.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50204	15041-20001-35387	3643 S EMPIRE DR 1-8	90034	5	120B165   769	4313003009	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.02527	-118.40381	05-15-2019 Changes to an permitted set of plans, changes include update as built changes(configuration layout). All changes are clouded as delta B. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50205	14041-20001-10871	20470 W NASHVILLE ST	91311	12	210B109   161	2707026019	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			Plans on Hold	05/07/2014 12:00:00 AM	ADDRESS	34.26998	-118.57907	this application is redudant. please ignore/refund	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50206	17041-20000-22495	10036 N SUNNY BRAE AVE	91311	12	204B109   416	2741024027	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.25273	-118.58081	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (56) modules, and (1) load center.  $0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50207	14041-20000-35672	10827 W CROCKETT ST	91352	2	192B177   711	2407024028	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.22038	-118.36594	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service pannel.(12) Sunpower E20/327 Panels(1) Power One PVI 3.8 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50208	18041-10000-14421	8327 S READING AVE	90045	11	096B169    79	4125004006	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	33.9627	-118.38216	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 22 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER. SYSTEM SIZE 7.26 KWDC 7.6KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50209	18041-20001-06012	4141 W SANTA MONICA BLVD	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. REUCTION IN SERVICE FROM 2000A TO 1600A. RELOCATING ELEVATOR MOTORS TO PANEL 1HP, CHANGES TO SINGLE LINE DIAGRAM, LOAD CALCS, AND PANEL SCHEDULES.*ORIGINAL*Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes a new service, new distribution equipment, lighting, and new loads throughout.Note: Building application has been generated under 17016-10000-17688	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50210	13041-20001-01216	17710 W ROSCOE BLVD	91325	12	192B129   324	2101001001	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.22072	-118.51902	VANILLA SHELL BUILDING. 800A SERVICE. NEW LIGHTING AND POWER FOR TENANT SPACES. THIS IS A RECHECK FOR LOST SET OF PLANS. PERMIT ALREADY ACTIVE. THIS IS A RESTAMP ONLY. POWER AND ENERGY. PC PER 2008 NEC AND ENERGY CODE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50211	12041-10000-24827	9214 N YOLANDA AVE	91324	12	198B121   601	2763011002	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.23777	-118.54031	NEW 7.2 KW ROOF MOUNTED PV SYSTEM FOR A SINGLE FAMILY. PV1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50212	17041-20000-18547	3258 S EDITH ST	90064	5	123B161   708	4316020005	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.03254	-118.40652	pv1install roof mounted pv system sized 11.7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50213	19041-10000-37916	333 S GRAND AVE 18th-Flr	90731	15	018B197  1671	7451019029	R2-1XL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM			PC Info Complete	09/20/2019 12:00:00 AM	ADDRESS	33.74081	-118.29031	Energy PC only for the 18th conferance room. area of scope 235sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50214	12041-10000-16985	2461 W WASHINGTON BLVD	90019	10	126B189   910	5073024013	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	PIN	34.04013353	-118.3167512	SERVICE UPGRADE FOR AN EXISTING AUTO REPAIR SHOP AND VERIZON WIRELESS.  REFEED EXISTING PANELS AND ADD NEW LOAD.  PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50215	17041-10000-21917	4011 S CENTRAL AVE	90011	9	115-5A209 261	5114010017	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.01063	-118.25682	PC FOR POWER AND ENERGY FOR  ADDITION TO (E) TWO STORY DRIVE-THROUGH  FASTFOOD RESTAURANT ( McDonalds). NEW SERVICE 1000A 120/208VTOTAL AFFECTED AREA 5097 SQ.FT. BL# 17014-10000-03112	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50216	11041-10000-05742	210 N LADERA DR	90077	5	141B157    93	4358006046	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2011 12:00:00 AM	05/09/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	PIN	34.08175061	-118.42308551	ADDITION TO RESIDENTIAL HOME.  CHANGE OF 400 AMP SERVICE TO 600 AMP SERVICE, WITH NEW 200 & 600 AMP PANEL FOR AC AND EXHAUST FANS.  36 NEW BRANCH CIRCUITS.((( This plan check is only for new srvice and panels , T.I is for future , no lighting power nor roofing plan is included in this approval.)))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50217	17041-10000-33820	13445 N GLENOAKS BLVD	91342	7	225B145    79	2501021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Issued	09/21/2017 12:00:00 AM	ADDRESS	34.31638	-118.4614	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50218	12041-10000-09746	12039 W OSBORNE ST Bldg 6	91331	7	210B165   543	2532017066	(Q)C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Pacoima		1041.06	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.27294	-118.39505	Thee-stories townhouses	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50219	19041-10000-04568	767 S ALAMEDA ST 4TH FL-SUITE 470	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	TI TO AN EXISTING COMMERCIAL BUILDING 6 STORY BUILDING'S 4TH FLOOR, CHANGE TO BUILDING LAYOUT ON 4TH FLOOR, SCOPE OF WORK (12) 225A PANELS, (8) 100A PANELS, (2) 75 KVA TRANSFORMERS, AND (8) 45 KVA TRANSFORMERS, INCLUDES T24, TOTAL SQUARE FOOTAGE = 50,971NOTE: MODIFICATION HAS BEEN FILED FOR EXISTING PEAK DEMAND READING PER ARTICLE 220.87.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50220	16041-10000-44023	1601 E OLYMPIC BLVD #324	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.02923	-118.24056	PC for energy only. Indoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 5850.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50221	15041-10000-43361	767 S ALAMEDA ST Bldg 2	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	RENOVATION OF EXISTING 6 STORY BUILDING AND CHANGE OF USE TO OFFICE/RETAIL/RESTURANT USES. CORE AND SHELL INSTALLATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50222	19041-20000-15514	23920 W HARTLAND ST	91307	12	183B089   687	2034029035	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.19427	-118.64722	Plan check for a PV1 roof-mounted PV system. System size is 6.8 kWdc/5.012 kWac-CEC and consists of (1) 6 kWac rated inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50223	14041-20001-01488	10410 N JELLICO AVE	91344	12	207B129  1035	2733012035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.25996	-118.51853	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50224	13041-10000-25821	14640 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Info Complete	01/08/2014 12:00:00 AM	ADDRESS	34.22128	-118.45128	This is a new parking lot , out door parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50225	16041-10000-19319	11021 W TUXFORD ST	91352	6	195B173    55	2408033041	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.23412	-118.37224	PC for T-24 only, Remove HID fixtures and replace to LED fixtures. Using existing branch ckt. Total area: 4,498 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50226	17041-10000-28944	1260 N PIEDRA MORADA DR	90272	11	135B121     6	4431033003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Expired	03/17/2020 12:00:00 AM	ADDRESS	34.07002	-118.55144	PC for new ground mounted 16.4kW pv system. Intalling 49 modules, one 5kW Invter, one 11.4kW Invter and one load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50227	15041-10001-27350	7447 N RUTHERFORD HILL DR	91304	12	186B089   333	2027045028	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM			PC Approved	08/31/2015 12:00:00 AM	PIN	34.20677858	-118.65014539	Expedited rses plan check per applicant request.<<<pv1 install new 13475 kw dc solar array for a single family home.(49) modules: rec solar recc275tp(1) inverter: solaredge se 11400a-us->>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50228	19041-20001-42643	5649 N COLBATH AVE	91401	2	174B153   592	2246030004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.17365	-118.4369	PV1. INSTALL 9.92 KW DC PV SYSTEM WITH (31) MODULES/OPTIMIZERS AND (1) INVERTER (SE6000H) NOTE: PARTIAL INSPECTION FEE UNDER 19041-90000-42643.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50229	18041-10000-29641	8349 N WINNETKA AVE	91306	3	192B113   479	2781017900	PF-1XL	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.2214	-118.57123	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50230	16041-10000-26452	21300 W VICTORY BLVD 9th floor	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.18813	-118.59618	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERICIAL BUILDING ON THE 9TH FLOOR. SCOPE INCLUDES NEW LIGHTS FOR CORRIDOR AND ELEVATOR LOBBY. TOTAL AFFECTED IS 1325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50231	15041-10000-37177	1211 W ALTON ST	90744	15	030B201   443	7416009014	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Expired	12/05/2017 12:00:00 AM	ADDRESS	33.77709	-118.27699	PV1 INSTALL 2.385 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (9) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50232	14041-10000-22296	24425 W CALVERT ST	91367	3	177B089   851	2032011074	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.18297	-118.65673	Installation of fire alarm system for new day care center.  Total number of modules = 85	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50233	14041-10000-09885	626 W WILSHIRE BLVD 1F	90017	14	129A209    83	5144006025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.04843	-118.25695	FEES UNDER SUBMITTAL 2. Plan check started as energy but realized it was PLACE OF ASSEMBLY. Plan check is now for POWER and ENERGY. Emergency lights installed - emergency circuit to be provided. fitness center. TI TO (E) BLDG. 3 SPACES CONSOLIDATED TO 1. 1ST Floor OF 12 STORY HIGHRISE. BLDG# application not submitted yet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50234	12041-10000-11982	8936 S SEPULVEDA BLVD # 200	90045	11	096B165  1080	4123001027	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	33.95499	-118.39596	PLAN CHECK T24 ENERGY/EMERGERNCY LIGHTING FOR OFFICE TENANT IMPROVEMENT ON 2ND FLOOR. PERMIT FOR NEW BRANCH CIRCUITS LESS THAN 400A INSTALLED LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50235	16041-20000-21203	10349 W DIAMOND ST LOT 7	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50236	18041-10000-33989	2007 W JEFFERSON BLVD	90018	10	120B189   675	5052023038	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			PC Approved	10/19/2018 12:00:00 AM	ADDRESS	34.02567	-118.31541	lost plan.......PLAN CHECK FOR ENERGY ONLY FOR - Change of use from (E) Retail to Office/Art Studio. Add two skylights,  remove portion of rear wall add storefont and double doors. Add new shearwalls.  No change in parking - TOTAL AFFECTED AREA = 894 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50237	16041-10000-34384	5455 S INGLEWOOD BLVD	90230	11	105B161   453	4220019033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Apartment			09/28/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	33.98529	-118.40735	PC FOR FIRE ALARM SYSTEM IN MULTI UNIT APT BUILDING. SCOPE OF WORK INCLUDES: 2 NEW PANEL : FACP AND COMM. PANELAND  46 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50238	14041-20000-12026	12642 W SANDHILL LANE Unit #1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97765	-118.41437	Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 1 of 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50239	14041-10002-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	33.95713	-118.3847	CHANGE TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2. RELOCATION OF DWELLING UNIT AND CIRCUITS. THIS IS PC ONLY. NO OTHER CHANGES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50240	09041-10003-21197	1511 N WILCOX AVE	90028				C4-2D-SN		Hollywood	Central Hollywood			Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	34.09839	-118.33114	as-built set of plans	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50241	19041-20000-29405	11263 N BALBOA BLVD	91344	12	210B133   116	2697021013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Issued	07/30/2019 12:00:00 AM	ADDRESS	34.2754	-118.50241	Plan check for Tilte 24 only in existing B Occupancy Church building, new lighting. Total area: 1953 sq ft. B#19016-20000-18427	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50242	15041-10000-40111	7508 W MELROSE AVE	90036	5	141B177   659	5526017027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	PIN	34.08337436	-118.35354775	PC FOR POWER AND ENERGY. TI TO AN EXISTING COMMERCIAL BUILDING (CVS PHARMACY). SCOPE INCLUDES NEW 1200A MAIN DISTRIBUTION PANEL, NEW SUBPANELS, AND NEW LIGHTING IN PARKING GARAGE AND IN RETAIL SPACE. TOTAL AREA IS 53981 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50243	16041-10004-10543	4865 N LOUISE AVE	91316	5	168B133   205	2290002003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM			Corrections Issued	11/17/2016 12:00:00 AM	ADDRESS	34.15843	-118.50997	Changes to approved set.  Derate circuit breakers from 22 kAIC to 10 kAIC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50244	11041-20000-00210	6626 N VALJEAN AVE	91406	6	180B141   319	2233029016	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.02	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	03/10/2011 12:00:00 AM	ADDRESS	34.19103	-118.48565	plan check T24 energy general/emergency lighting for dance studio TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50245	10041-20000-20369	3751 S HILL ST	90007	9	117A203    42	5122028001	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM			PC Approved	10/13/2010 12:00:00 AM	ADDRESS	34.01564	-118.27766	lobby and outdoor entry lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50246	19041-20000-34253	4404 S GRAND VIEW BLVD	90066	11	108B157   255	4232020019	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	33.99476	-118.42201	PV1 EXPEDITED PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.16 KW. SCOPE OF WORK CONSISTS OF (31) PV MODULES WITH MICRO INVERTERS, (2) BATTERY 27 KWH SYSTEM, AND A NEW PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50247	16041-10000-04555	350 S GRAND AVE lobby	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE LOBBY LEVEL. SCOPE INCLUDES NEW LIGHTS FOR THE OUTDOOR CANOPY AND NEW LIGHTS FOR THE LOBBY AREA. TOTAL AFFECTED AREA IS 2396 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50248	16041-10000-29576	1630 N NORTH MAIN ST	90012	1	136-5A219 638	5409013913	UI(CA)	Central	Central City North			2060.10	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM			Corrections Issued	08/19/2016 12:00:00 AM	ADDRESS	34.06682	-118.22728	Installation of roof mounted solar PV array on existing industrial building.  Feed in tarrif project.  Total system size = 3.92 kWac.  14 Enphase S280 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50249	16041-10000-37115	7640 N TAMPA AVE	91335	3	186B117    83	2104012066	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.20967	-118.55333	PC for power (I2 exempt form energy)Electrical change of use to ambulatory surgery center. NON OSHPD 3 PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50250	18041-10000-02513	404 S FIGUEROA ST	90071	14	130-5A209 238	5151020***	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.05326	-118.25596	PC for new 1200A switchboard section SSAH-H supplying boiler equipment, lights and pump equipment in equipment room in Bonaventure hotel . New 1200A section build out to be connected to existing 1600A section. See Comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50251	17041-20000-43096	15760 W VENTURA BLVD Suite 2000	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check for Title 24 only. Project site is a part of the 20th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,753 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50252	17041-10002-14793	1313 W SILVIUS AVE	90731	15	006B193    78	7470025026	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	33.71542	-118.30662	PC for one new Powerwall2, 225A load center, downsized main breaker. Total system size is 5.8kVA. Permit fees are under 17041-90000-14793	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50253	13041-10000-16746	921 N HIGHLAND AVE	90038	4	144B185  1094	5532012038	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.08774	-118.33877	FA FOR GYMNASIUM. 15 devices and 1 panel. 2 stories	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50254	17041-10000-46545	1414 N CATALINA ST	90027	13	147B197   848	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Issued	12/28/2017 12:00:00 AM	ADDRESS	34.09716	-118.29486	PERMIT FOR SERVICE AND SERVICE EQUIPMENT WHICH WAS APPROVED ON THE MAIN APPLICATION 17041-20000-14243	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50255	13041-10000-33845	1300 W 177TH ST BLDG E	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.87031	-118.29542	PLAN CHECK FOR POWER AND ENERGY NEW BUILDING. 1 STORY. BUILDING E( MEETING BUILDING).  PANEL HPF CHARGED UNDER BUILDING F 13041-10000-33846. Provision for EV charger on either of the panels serving E or F. Outdoor lights for decoration only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50256	18041-10000-04005	221 S AVENUE 55	90042	1	150A229   163	5468028016	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.20	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	06/16/2018 12:00:00 AM	ADDRESS	34.10559	-118.19435	NEW ROOF MOUNTED PV SYSTEM. CONSISTS OF 19 MODULES (JINKO 290W PV MODULES), OPTIMIZERS(SOLAR EDGE P320) AND 1 INVERTER(SOLAREDGE SE5000A-US)SYSTEM SIZE IS 5.51KWdc/5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50257	17041-10001-12433	992-998 W 8TH ST	90017	14	129A207   123	5144022028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.04846	-118.26264	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE REVISION OF LIGHTING AND CIRCUITS. NOTE CHANGES UNDER DELTA 2 CLOUDED AREAS. PLAN CHECK ONLY___________________________________________Plan check for power and Title 24.  Change of use from garage to 3 separate shell retail spaces.  New EV chargers, lights, receptacles, and HVAC.  Total connected load exceeds 400 amps.  Total area = 2,241 sq. ft.     Building permit #17016-10000-06201	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50258	10041-10006-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/21/2013 12:00:00 AM			PC Approved	02/21/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	REVIEW OF CHANGES TO PERMITTED SET OF PLANS AS CONSTRUCTION CONTNUES; CHANGES ARE IN THE TBIT WEST CORE AT DIFFERENT LEVELS AND INCLUDES NEW PANELS AND CKTS((((((((((single line diagrams with existing switchboards and distribution boards supplying tenant panel boards at the North and South Concourses Concessions. Review was requested such that approved plans will be on site as tenants are now moving into and modifyiny their tenant spaces. These show the tenant design loads and any modification from the design loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50259	15041-20000-02111	16121 S HOOVER ST	90247	15	069B197   252	6120020011	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	33.88468	-118.28719	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50260	14041-10000-34763	11908 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.05238	-118.47057	Tiyle  24 for a smal restaurant / coffee shop. ,  one story building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50261	15041-20000-12581	23751 W BURTON ST	91304	12	192B089    82	2020010015	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.21875	-118.64492	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER WITH 24 MODUKES. SYSTEM USES POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50262	15041-10000-04121	330 E 2ND ST # C	90012	14	129A213   113	5161022022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.04859	-118.24099	CHANGE OF USE FROM RETAIL TO RESTAURANT.OCCUPANT LOAD IS LESS THAN 50PLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50263	16041-20000-05986	600 W 7TH ST 6th Floor	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.04728	-118.25685	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of (3) 800-kVA UPSs, (3) 2500-amp battery disconnects, (3) 600-amp battery disconnects, and (6) 225-amp panels. Panels loads are all future loads and are not part of this scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50264	19041-10000-10643	2533 W 3RD ST	90057	13	135A203    57	5155033018	C2-1	Central	Westlake	Echo Park	YES	2085.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.0655	-118.27742	Replace fluorescent troffers with new LED retrofit kits (Indoor Only). Located in tenant space: Chirla Coalition Main.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50265	15041-10000-14600	9748 N VARIEL AVE	91311	12	201B105   136	2746003021	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.24773	-118.59279	TI-24 REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. PC FOR ENERGY ONLY. TOTAL SQ. FT. 14,276.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50266	17041-10000-00066	13589 N VIA SANTA CATALINA	91342	7	228B165    83	2581006***		North Valley				1061.11	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.31895	-118.39769	PV, INSTALL 4.53 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(18) MODULES: HANWHA Q-CELL. Q-PLUS BFR-G4.1 280V(1) INVERTER: SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50267	17041-10000-04709	121 N AVENUE 53	90042	1	151-5A227 341	5468020022	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.10764	-118.19853	PV FOR PV SYSTEM ON COMMERCIAL ROOFTOP. TOTAL SIZE 7.7KW AC USING 25 MODULES IN TOTAL WITH CENTRAL INVERTER SYSTEM	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50268	11041-10000-04175	15524 W LANARK ST	91406	6	189B145    64	2654040004	M2-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Closed	08/17/2011 12:00:00 AM	ADDRESS	34.21839	-118.47093	INSTALLATION FOR NEW MANUAL FIRE ALARM SYSTEM.  18 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50269	18041-20000-24812	6041 N VARIEL AVE	91367	3	177B105    60	2149005016	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Closed	04/01/2022 12:00:00 AM	ADDRESS	34.1802	-118.59303	temp power for construction site 800 amp.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50270	13041-20000-06191	5244 N DON PIO DR	91364	3	171B105   435	2168016077	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.16552	-118.60453	New pv system for an existing single family dwelling.  System is ungrounded, transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50271	16041-20000-16112	5161 N LANKERSHIM BLVD	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.16452	-118.37469	Paln check for power and energy load exceed 400A. Replace chillers, fan motors and pumps in office building 4 story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50272	18041-20001-24835	8008 N VAN NUYS BLVD	91402	6	189B149   632	2212028019	[Q]C2-1-CDO, [Q]C2-1VL-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			PC Approved	09/05/2018 12:00:00 AM	ADDRESS	34.21647	-118.44851	9/5/2018changes to an approved set of plans. changes noted delta 1.  changes to reflect field conditions,  panel circuiting.this is plan check only. (((ti to an existing commercial building single story.  adding new lighting new controls to new panel.  newly connected load <400 amps.  plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50273	17041-10001-01899	6670 W 85TH PL	90045	11	096B161   591	4112029018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM			Reviewed by Supervisor	02/01/2017 12:00:00 AM	ADDRESS	33.96029	-118.40688	EXPEDITED RSES P[L;AN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50274	16041-10000-19283	8101 W MELROSE AVE	90046	5	141B177   568	5528007014	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.08389	-118.36609	COMPLETE REWIRE OF EXISTING BUILDING REMODEL. PER BUILDING, PC IN ACCORDANCE TO 2008 ENERGY CODE. NEW SERVICE AND DISTRIBUTION THROUGHOUT. NEW LIGHTING AND POWER. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50275	11041-20000-01185	1822 N OLD ORCHARD ROAD	90049	11	135B137   211	4426013016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	08/25/2011 12:00:00 AM	ADDRESS	34.0679	-118.49309	New roof mounted 15.05 KW  P.V. system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50276	16041-10000-26110	1540 N SKYLARK LANE	90069	4	147B169   499	5561004017	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM			PC Approved	09/07/2016 12:00:00 AM	ADDRESS	34.09909	-118.3877	PC FOR POWER ONLY FOR A NEW SINGLE FAMILY DWELLING. SCOPE INCLUDES A NEW 800A 120/240V 1 PHASE 3 WIRE SERVICE, AND 9 NEW SUBPANELS. Modification has been filed for Car lift under app.# 500681 ETL. ***Permit is under Building SFD 'Combo' B# 14010-30000-02185	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50277	14041-20000-01268	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.23541	-118.47521	replace lost plans	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50278	15041-20002-01301	14511 W DAUBERT ST	91345	7	207B149    96	2615027019	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM			PC Approved	03/20/2015 12:00:00 AM	ADDRESS	34.26716	-118.44875	3/20/2015 Changes to an approved set of plans. Changes were made to the layout of the PV modules on the roof. PV module layout changes are reflected on all affected sheets. All changes have been clouded and marked as Delta 2.CHANGES TO APPROVED SET OF PLANS. CHANGE IN LOCATION OF AC DISCONNECT. RESTAMP NEW SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50279	13041-10001-35675	5835 N DONNA AVE	91356	3	174B121   777	2156012036	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.17647	-118.54771	Expedited RSES plan check per applicant request.{{PV1, Install 13.75 kW DC roof-mounted solar array for a 3 story house, interconnect with main service panel. (1) inverter: Fronius IG Plus V 11.4. (55) modules: Hanwha HSL60P6-PB-4-250TW.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50280	17041-10000-29448	1536 W 228TH ST ste. A	90501	15	045B193   410	7347017077	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	33.8189	-118.30499	PC for T24 energy only, replace indoor and outdoor existing fixtures with LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50281	11041-10002-06215	458 S HARTFORD AVE 1-66	90017	1	132A207   104	5153023034	CW	Central	Westlake		YES	2091.03	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM			PC Approved	04/01/2012 12:00:00 AM	ADDRESS	34.05693	-118.26342	Modification to approved set of drawings,  System is changed from Line-side to Load-side and uses a variable trip breaker.   <<<New 43. KW PV system for an appartment Bldg. EPC is for power.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50282	15041-10000-05839	1193 N PIEDRA MORADA DR	90272	11	135B117   107	4431032005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.06756	-118.55159	PV1.  8.32 kW roof-mounted system with (32) Kyocera KU260 modules, (2) ABB PVI-3.6-OUTD inverters  and (1) load center interconnecting through the main service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50283	19041-20000-44012	3140 N OAKDELL LANE	91604	2	156B169   140	2382002009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.1269	-118.39027	PV1.  Install 12.8 kW AC roof mounted grid tied PV system.  (35) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50284	14041-10000-03002	10421 W VENICE BLVD	90034	5	117B165    77	4314003017	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.02039	-118.40476	replacing 600A swbd; overhead drop is existing; loads remain the same;adding 200A PANEL BOARD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50285	18041-20000-46951	13271 W SEVILLANA WAY LOT 8	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.31518	-118.4227	Plan check for PV roof mounted system,system size: 1.68KW with 7 PV Modules and7 microinverters. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50286	18041-10000-47806	865 S FIGUEROA ST 3450	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.04653	-118.26275	INTERIOR OFFICE T.I. 7,500 SQFT. OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50287	14041-10000-24754	380 WORLD WAY Space 88	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	10/23/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 plan check only.  Total area = 46 sq. ft.T.I. to airport terminal kiosk.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50288	16041-10000-18598	633 W 5TH ST STE 6650	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY.T.I. Remodel of existing, Demo and construction of non bearing interior walls. TOTAL AREA 3177 SQ FT. t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50289	12041-10000-18517	4609 N VAN NUYS BLVD	91403	4	168A151   147	2265012004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.15506	-118.44889	Plan check for energy and emergency lighting. 3013 sqft. hot wings cafe. Occpancy load is less than 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50290	16041-20000-14416	3808 S BAGLEY AVE	90232	5	120B165   772	4206030003	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.02522	-118.39466	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTD LOAD <400AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOATGE 2556.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50291	12041-10000-19218	10516 N ETON AVE	91311	12	207B105   553	2706022017	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.26135	-118.59447	Plan check for new 9.8KW roof mounted photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50292	18041-10000-04799	400 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.04446	-118.25616	DESIGN BUILD. Energy plan check for outdoor canopy lighting. Total area is 460-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50293	13041-20002-20342	1420 S FIGUEROA ST	90015	9	126A205   176	5134009019	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			04/16/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	34.03815	-118.26937	"CHANGES TO APPROVED SET OF PLANS. DELTA ""3A"" REVISIONS. UPDATE TO REFLECT FIELD CONDITIONS. NO CHANGE IN LOAD OR OTHER CALCULATIONS. CHANGE IN SINGLE LINE ONLY 3A"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50294	13041-20001-19315	21052 W OXNARD ST	91367	3	177B105    77	2149002033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	34.17902	-118.59237	Plan check for energy and emergency lighting. Office spaces in a single-story commercial building. Electrical tenant improvement	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50295	13041-10001-16328	299 WORLD WAY parking	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	33.94454	-118.40534	PLAN CHECK ONLY. plan check fees on original application.][][] supplemental to existing work under 13041-10000-16328 (not yet approved) . supplemental is to account for the addition of lighting work in parking garage elevator and lighting upgrade. total projected area in new scope of work is 191,416 sq ft of illuminated area. Since the area is > 30,000 sq ft it could not be charged under submittal-2 fee under the original 10000-series application, which was marked over the counter. NOTE: SUBMITTAL-2 UNDER PC # 13041-100001-16328 WAS TO CHARGE FOR OUTDOOR LIGHTING AREA ( +3647 SQ FT) THAT WAS NOT ACCOUNTED FOR DURING SUBMITTAL-1][][][PLAN CHECK FOR TITLE 24 PART 6 ENERGY AT LAX. SINGLE TOWER FOUR FLOORS. SCOPE OF WORK < 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50296	16041-10003-38144	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	11/14/2018 12:00:00 AM	ADDRESS	34.26153	-118.50259	Supplemental plan check for re-designed PV2 solar system. System size, inverters and modules qty are remain the same; However, system to add new load centers (1) 200A and (1) 400A, system interconnect to main switchboardS are redesigned as well. (8) inverters connect to a switchboard, (3) inverters connect to another switchboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50297	18041-20001-17418	11015 N LOUISE AVE	91344	12	210B133   673	2696002009	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM			PC in Progress	05/19/2018 12:00:00 AM	ADDRESS	34.27014	-118.51122	Expedite per applicant request, Plan chekc fpr PV roof mounted system with battery back up, system size:7.6kW with 24 modules and 1 inverter(7.6kw)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50298	18041-20000-17107	15355 W SHERMAN WAY #F	91406	6	183B145    36	2222027039	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.20139	-118.46803	Plan check for Title 24 only. Project site is an exising tenant space is a commercial building. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 899 sq. ft.Note: Building permit has been issued under 18016-20000-04385	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50299	15041-20000-00893	5155 N BASCULE AVE	91364	3	171B109   186	2166028023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.16436	-118.58664	PV1. Install roof mounted PV system sized 11.76 kW. Interconnected with main service pannel.(49) MonoX LG300N1C Modules(49) Enphase M250 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50300	18041-10000-36749	20001 W RINALDI ST	91326	12	210B113    29	2701004***	[T]RE20-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	08/26/2020 12:00:00 AM	ADDRESS	34.27571	-118.57047	NEW 'CORE AND SHELL' BUILDING, NEW SERVICE, TRANFORMER, PANEL & LOADS. POWER & ENERGY  (6,992sqft)BUILDING PERMIT: 18010-10000-04519	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50301	16041-10000-25704	2000 S COTNER AVE	90025	5	126B153   513	4323024038	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.0421	-118.44158	PC FOR POWER. UPGRADING SERVICE FROM 400A TO 800A 120/240 3 PHASE 4 W. INDUSTRIAL BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50302	15041-10000-32153	9043 N LURLINE AVE Build.6	91311	3	198B109   193	2780001058	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Expired	10/25/2017 12:00:00 AM	ADDRESS	34.23512	-118.58442	PC ON SPRINKLER MONITORING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50303	16041-20001-45352	7043 N MAYNARD AVE	91307	12	183B097   294	2024020019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	34.19879	-118.62252	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv array, roof-mounted on a SFD. Interconnect with a 225A MSP.17.92kW ungrounded system. (56) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50304	12041-10000-22503	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	TEMPORARY RELOCATION OF PASSENGER BOARDING EQUIPMENT FROM EXISTING SOUTH CONCOURSE TO NORTH CONCOURSE GATES 119 AND 120. PART OF WORK BEFORE DEMOLITION OF SOUTH CONCOURSE.INSTALLATION OF NEW TEMPORARY DISTRIBUTION BOARDS TO KEEP NORTH CONCOURSE OPERATIONAL; INSTALLATION OF NEW DIST BDS AT EXISTING GATE 123 FOR TIE IN WITH  NEW BRADLEY WEST BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50305	16041-10000-24669	2368 W PICO BLVD	90006	1	129B197  1081	5056004007	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Apartment			07/13/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Closed	11/09/2020 12:00:00 AM	ADDRESS	34.04706	-118.28833	Full Plan check on a New 4 story 10-units Apartmenet build with 7-typical units. 1 subterranian parking, and 1st floor is use as Medical Office. 1000A MS, total area: 18,523 sq.ft*Build. # 15010-30000-00412	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50306	10041-20000-24731	14006 W RIVERSIDE DR #S273	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	01/04/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check T24 Energy (general/emergency) lighting for suite #S273	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50307	12041-10000-17185	11023 N CARDAMINE DR	91042	2	210B197   320	2552027013	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.20	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2012 12:00:00 AM	09/26/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.26931	-118.2973	New UNGROUNDED 5.28kw rooftop mounted photovoltaic system for an existing  single family residence.  System uses SolarEdge DC/DC Converters charged under Misc. for Permitting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50308	11041-10000-25732	6801 W HOLLYWOOD BLVD D3-331	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	12/30/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	"Install general/emergency lighting in existing retail space ""Lids"" om Hollywood and Highland Mall.  Plan check for energy only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50309	17041-20000-18426	816 S FIGUEROA ST ste 200	90017	14	129A207   173	5144021035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM			PC Approved	06/02/2017 12:00:00 AM	ADDRESS	34.0474	-118.26148	ti to an existing restaurant.  adding new lighting new controls to new panel.  newly connected load less than 400 amps.  plan check for energy and em lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50310	15041-10000-31496	701 E 3RD ST	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	PIN	34.04581508	-118.23784015	T-24. PC FOR ENERGY ONLY. TI SHELL AND CORE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING FOR THE GROUND, 2ND, 3RD, AND 4TH FLOOR RESTROOMS AND LOBBY. TOTAL AREA IS 4656 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50311	11041-10000-15817	8401 N VAN NUYS BLVD # 9	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Approved	08/01/2011 12:00:00 AM	ADDRESS	34.22308	-118.44896	T.I.  Existing ice cream shop.  Remodel of some light fixtures in the food prep area.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50312	18041-10000-25770	21036 W LULL ST	91304	3	186B105    96	2109024007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.20932	-118.59194	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM SIZE =3.8KVA WITH CENTRAL INVERTER(SE3800H-US) WITH 13 PANELSUSING POWER OPTIMIZERS(P-320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50313	18041-10000-03559	6221 W 96TH ST	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	33.94902	-118.39331	PC for T24 only for new outdoor fixtures. Installing new lights in parking lot of LAX. Installing three new panels, 37.5kVA transformer, lights and receptacles, equipment. 70000sqft. B#17026-10001-00441.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50314	19041-20000-04441	8333 N VAN NUYS BLVD	91402	6	192B149   303	2638038002	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.22236	-118.44896	new fire alarm system 136 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50315	11041-10001-19246	6701 N ETON AVE 1-298	91303	3	180B105    27	2148030035	(WC)C/I-60/1.0	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			09/17/2012 12:00:00 AM			PC Approved	10/15/2012 12:00:00 AM	ADDRESS	34.19217	-118.59564	Changes to previosly approved sets, , changes to title 24, feders and interior lightings.   No new ckt or panels. Revise elevator 1, 2, and 3, remove load from existing panels and relocate receptacle and luminaires. EPC is for delta I only. 9-13-12   (((((((((((((((((NEW FIVE-STORY, TYPE-III-A, 298-UNIT APARTMENT WITH ATTACHED PKG GARAGE (Automatic fire srpinkler throughout for the story increase). See separate permit  for attached parking garage.Need to file a variance to separate the FA plans from the electrical plans.Plan check fees were determined by client.))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50316	18041-10000-09594	11128 W GAULT ST	91605	2	183B173   145	2319022001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.19927	-118.3737	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50317	17041-20000-45572	17020 W ESCALON DR	91436	5	162B133   205	2287003034	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.13944	-118.50254	Plan check for solar pv system w/roof-mounted array for SFD.10.4kW ungrounded system. (2) 5.2kW inverters.(36) 300W pv modules.Derating main breaker from 200A to 175A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50318	18041-10001-11409	3377 W WILSHIRE BLVD #209-210	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Approved	10/23/2018 12:00:00 AM	ADDRESS	34.06193	-118.29742	DELTA CHANGES TO APPROVED PLANS FOR REDUCING LIGHTS. TITLE24 ENERGY ONLY. PLAN CHECK ONLY. PERMIT WAS ISSUED: 18041-10000-11409SCOPE INCLUEDS NEW CIRCUITS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 2137SQ. FT.  B# 18016-10000-00128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50319	15041-10000-43001	1925 S CENTURY PARK EAST 16th-Floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 1 REVISIONS. ORIGINAL APPLICATION UNER 15041-10000-40136	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50320	17041-20000-34647	19433 W RUNNYMEDE ST	91335	3	186B117   482	2116016065	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.20575	-118.55685	Plan check for solar pv system, roof-mounted array on SFD.5.88kW ungrounded system. (21) 280W AC modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50321	16041-10000-32575	26640 S WESTERN AVE	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	33.78015	-118.30862	DESIGN-BUILT; CHANGE OF USE FROM RETAIL TO CHARTER SCHOOL. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AREA IS 7690 SQ FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50322	17041-20000-04134	1800 N VINE ST	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.10393	-118.3265	(2/8/2017)replacement of lost plans. addition of (2) UPS 4.8kva to an existing commercial office building non-high rise. adding em lighting with new circuits.  this application to include general lighting for bathrooms and garage/garage lobby only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50323	17041-10000-19303	4501 N DESERET DR	91364	3	168B097   697	2074039016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	Yes	1374.02	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.1529	-118.63001	replace lighting with LED type	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50324	15041-10000-06079	630 W HARRY BRIDGES BLVD	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	33.77068	-118.26868	ROOF-MOUNTED ( ADMINISTRATION BLDG) INSTALLATION OF 7.2KW DC PHOTOVOLTAIC SYSTEM	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50325	15041-20000-09456	10808 N SUNNY BRAE AVE	91311	12	207B109   141	2707006007	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.26663	-118.58037	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (42) modules, and (1) 100-amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50326	13041-10000-01320	2500 S WESTERN AVE	90018	8	123B193   477	5058015005	C2-1, RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.03373	-118.30879	NEW 4 STORY BUILDING FOR OFFICE USE AND 2 STORY UNDERGROUND PARKING GARAGE, 2 ABOVE GROUND PARKING AND 2 STORIES OF OFFICE. NEW 4000A SERVICE. PC IS FOR T24 AND POWER. TOTAL AREA OF 186542 SQ FT. IMPORTANT >> METHANE HAZARD SITE, UNDERGROUND WORK PERFORMED<<PRE-MADE CHECK, PLEASE VERIFY # OF EQUIPMENT INSTALLED AND FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50327	17041-20000-25471	10250 W CONSTELLATION BLVD Suite 2850	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Issued	10/23/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for energy only. TI to existing office suite 2850 in high rise building. New lighting - 1,727sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50328	13041-10000-23237	620 S UNION AVE	90017	1	132A205   143	5142028031	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.05638	-118.26929	NEW FIRE ALARM SYSTEMS. FULLY-SPRINKLED SYSTEM, 10,700 SF. TOTAL NUMBER OF STORIES IS 3, WITH ADDITION OF A ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50329	19041-20000-16128	20744 W BEECH CIR #310-pv1	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.29367	-118.58554	pv1install roof mounted pv system sized 3.02KW AC interconnected with msp.  (9) acm at 335 W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50330	15041-20001-29388	11767 N CHIMINEAS AVE	91326	12	216B125   286	2870019035	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM			Reviewed by Supervisor	09/14/2015 12:00:00 AM	ADDRESS	34.28508	-118.53351	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (58) modules, (1) combiner box, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50331	19041-10000-35973	17025 W MARLIN PL	91406	6	183B133   563	2230005030	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.19722	-118.50422	Standard plan check for a PV1 3.8kw AC roof mounted system. Scope includes (1) inverter, (15) modules and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50332	14041-10000-18413	5535 S WESTLAWN AVE 1-309	90066	11	105B161  1012	4211005021	(Q)C2-2	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM			PC Approved	09/10/2014 12:00:00 AM	ADDRESS	33.98024	-118.41489	Title 24 plan check only. Total area = 3611 sq. ft. Title improvement to lobby, fitness center, leasing office, and exisitng apartment space. Change in lighting and recepticals.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50333	16041-10000-24889	649 E PALMS BLVD	90291	11	108B145  1037	4241012025	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	33.99179	-118.46283	PV1, INSTALL NEW 6 KW ROOF-MOUNTED PV SOLAR ARRAY WITH 5 KW, 13.5 KWH BATTERY BACK UP ON EXISTING SINGLE FAMILY HOUSE.      $0.00 PERMIT FEE DUE TO CALIFORNIA SENATE SOLAR BILL #1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50334	18041-20000-27644	20412 W ELKWOOD ST	91306	3	189B113  1023	2107013051	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.21225	-118.57759	pv1install roof mounted pv system sized 2.5KW AC interconnected with msp.(12) ES-195 evergreeen solar modules(1) SMA america inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50335	18041-10001-47410	234 S RIMPAU BLVD	90004	4	135B185    40	5515008035	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM			PC Approved	01/04/2019 12:00:00 AM	ADDRESS	34.06983	-118.3302	EXPEDITE PER CUSTOMER REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50336	16041-10000-02431	12655 W JEFFERSON BLVD	90066	11	102B161    13	4211005019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	33.97916	-118.41469	TI on (E) office building. Install new lighting & control receptacles on partial 1st floor and 2nd floor. PC for energy only. Total area: 15,733 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50337	15041-20000-02662	12500 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/31/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50338	14041-20001-01886	1440 W 37TH PL	90018	8	117B193   290	5041029008	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/02/2014 12:00:00 AM	ADDRESS	34.01987	-118.30159	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50339	17041-10002-00387	7157 WORLD WAY WEST F/A	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	33.94331	-118.4195	Plan check only. CHANGES TO APPROVED SET UNDER DELTA 6. CHANGES ONLY COVER REPLACING BOSCH B465 COMUNICATOR WITH TH-7LV COMMUNICATOR.  Plan check for new fire alarm system new substation. Total fire alarm devices: 22 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50340	17041-10001-40003	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/28/2020 12:00:00 AM	ADDRESS	34.07196	-118.24719	Revision to an approved set noted as Delta-3, changes include adding branch circuits, adding receptacles to existing branch circuit , revised floor plan elevatir hoistway lightings, revised panel schedule and T24 forms accordingly.B# 16041-10000-02730	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50341	19041-10001-31286	9215 W CATTARAUGUS AVE	90034	5	123B165   206	4301002007	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM			PC Approved	09/04/2019 12:00:00 AM	ADDRESS	34.03591	-118.39277	Change to an approved set by rearrange the number of module and the layout on the plan.(((pv-1 for 22 modules (panasonic VBHN330SA16) WITH OPTIMIZERS (SOLAREDGE P400). INVERTER (SOLAREDGE SE7600H-US). )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50342	15041-10000-13125	2630 S ALMA ST	90731	15	009B197   863	7463017005	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM			Verifications in Progress	06/23/2015 12:00:00 AM	ADDRESS	33.72005	-118.29889	PV1, INSTALL 2.86 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(11) MODULES: KYOCERA KU2606XPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50343	17041-10000-20148	10250 W SANTA MONICA BLVD FC-8	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Info Complete	07/20/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"ALTERATIONS IN FOOD COURT EATERY ""TIPSY COW"".  PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50344	11041-10000-09545	1055 W 7TH ST	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.0507	-118.26334	EXISTING FIRE ALARM.  ADDING AN ADDITIONAL 192 DEVICES AND POWER BOOSTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50345	14041-10000-30845	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016023	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.08758	-118.34425	Changes to approved set.  Addition of 44 fire alarm devices to an existing mixed use property.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50346	12041-20000-28142	76 S BEVERLY PARK LANE	90210	5	156B161    62	4386008016	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.12348	-118.41521	Plan check for power. Single family dwelling. New 2000A service. All new equipment, circuits are in bold (lighter lines are there for reference only [existing]).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50347	18041-20000-48202	1533 W COLORADO BLVD	90041	14	162A227    38	5669012011	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.13972	-118.19932	PV3.  Install 5.11 kW DC roof mounted grid tied PV system.  (14) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50348	17041-20000-15151	8717 N DARBY AVE	91325	12	195B125   809	2769025011	M1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.2292	-118.53371	new fire alarm system.  77 devices plus 1 facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50349	12041-20000-29187	9105 W HAZEN DR	90210	4	153B165    74	4388020014	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2011 12:00:00 AM			PC Info Complete	12/04/2012 12:00:00 AM	ADDRESS	34.11815	-118.39566	change feeders from coppers to aluminum and add 200kw generator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50350	19041-10000-48027	13955 N BALBOA BLVD	91342	7	228B137   226	2603025028	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.323	-118.49033	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50351	19041-10000-26373	540 S GAFFEY ST	90731	15	015B197  8035	7451029029	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	33.73896	-118.29214	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50352	12041-10000-24520	11160 N STRANWOOD AVE	91345	7	210B145     7	2664001***	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Public Safety Only			10/15/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.27332	-118.46675	Replace an existing fire alarm system with a new one. New panel and devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50353	14041-10001-14240	5715 N COLFAX AVE	91607	2	174B169   521	2339010008	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	PIN	34.17446004	-118.3881065	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH POWER OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50354	16041-20000-34063	600 E IMPERIAL HWY	90059	15	087A207   290	6072004026	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	33.93089	-118.26467	change of use from laundry mat to reatail store single story.  new 600 amp service core and shell, renovation.  plan check for power and energy. building application number 16016-10000-08786	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50355	19041-20000-13445	959 N SEWARD ST 4TH FL	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	T24 PLAN CHECK FOR EXISTING COMMERCIAL BUILDING TI. TOTAL SQUARE FOOTAGE = 3805 SF. LIGHTS AND OUTLETS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50356	15041-20000-34481	24244 W GILMORE ST	91307	12	180B089  1045	2033013024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Expired	11/20/2017 12:00:00 AM	ADDRESS	34.18555	-118.65377	PV1. NEW ROOF-MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 6KWac. (28)MODULES- KYOCERA#KU2656ZPA(1) INVERTER-ABB#PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50357	15041-10001-03969	27 E WAVE CREST AVE # 3	90291	11	108A143   245	4226003015	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	33.99013	-118.47518	EXPEDITED RSES PLAN CHECK PER APPLICANT REQEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50358	13041-10001-12998	380 WORLD WAY Space T26	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Added two new panel boards and 2 ea 30kva transformers and removed 75 kva transformerPROPOSED FIRST TIME  TENANT IMPROVEMENT N SPACE T26  (TBIT ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50359	13041-10000-15723	1875 S CENTURY PARK EAST #400	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM			PC Approved	06/14/2013 12:00:00 AM	ADDRESS	34.06115	-118.41457	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO EXISTING SUITE #400. PERMITS SHALL OBTAINED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50360	16041-20000-45075	6060 W CENTER DR Ste 825	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	33.97602	-118.39073	TI to (E) commercial office spaces in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50361	16041-20000-02463	6556 N FARMDALE AVE	91606	2	180B169   612	2335002001	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.19013	-118.38109	PV1. Install roof mounted PV system sized 3 kW. Interconnected with main service panel. (8) Solarworld 260W Modules(1) ABB PVI 3.0 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50362	17041-10000-16302	1723-1725 N IVAR AVE	90028	13	148-5A187  86	5546005016	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.10239	-118.32831	OFFICE TI. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50363	16041-10002-10543	4865 N LOUISE AVE	91316	5	168B133   205	2290002003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Expired	06/21/2018 12:00:00 AM	ADDRESS	34.15843	-118.50997	($0 PERMIT FEE PER SENATE BILL 1222.) Supplemental PC and Permit, changes per field installation : revised module layout and added new 200A Sub Main Panel.<<$0 PERMIT FEE PER SENATE BILL 1222.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 29.430KWdc / 25.4KWac.(90)MODULES-SPR-327NE-WHT-D(4)INVERTERS-2 SMA SB7700TL-US-22 AND 2 SMA SB5000TL-US-22>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50364	18041-20000-02286	22846 W VENTURA BLVD	91364	3	171B097   554	2042005062	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.16531	-118.62473	PLAN CHECK FOR ENERGY ONLY. SERVIE SIZE <400A FOR NEW STORAGE BLDG  AND AUTOMOBILE RENTAL AND SALES. TOTAL AFFECTED AREA = 20155 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50365	15041-10000-20455	317 S BROADWAY STE. A3-A4	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.05069	-118.24861	TI-24. PC FOR ENERGY ONLY TO AN EXISTING RESTAURANT. TOTAL AREA 535 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50366	16041-20000-01546	1659 N MALTMAN AVE	90026	13	145-5A203 342	5429022021	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.09219	-118.27548	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel. (16) Kyocera KU2656 Modules(1) Solaredge SE3800 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50367	18041-10002-08316	3489 S MAPLEWOOD AVE	90066	11	114B149  1035	4244022016	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.00497	-118.44891	PC FOR CHANGES TO APPROVED SETS PER FIELD INSTALLATION. SCOPE OF CHANGES INCLUDES: REPOSITION OF MODULES ON THE ROOF, RELOCATION OF PV EQUIPMENT ON THE EXTERIOR OF THE HOUES. RELOCATION OF MONITORING CIRCUIT. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50368	17041-20000-03233	11211 W VENTURA BLVD	91604	2	162B173   255	2366035036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.14214	-118.37468	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OUTDOOR LIGHTING. 3356 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50369	16041-20002-20447	326-338 S RENO ST	90057	1	136-5A201 249	5155009013	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Apartment			05/22/2019 12:00:00 AM	01/25/2021 12:00:00 AM		Permit Finaled	01/26/2021 12:00:00 AM	ADDRESS	34.06744	-118.28363	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. ADDITION OF  BOOSTER PUMPS , BOOSTER PUMP CONTORL PANEL, AND A 30A PANEL. CHANGES TO SINGLE LINE DIAGRAM, PANEL SCHEDULES, FEEDER SCHEDULE, FAULT CURRENT SCHEDULE, VOLTAGE DROP SCHEDULE, AND SOME FLOOR PLAN CHANGES. CLOUDED DELTA D CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50370	13041-20000-11297	2331 S GRAND AVE PV2	90731	15	009B197   365	7465007015	RD1.5-1XL	Harbor	San Pedro	Coastal San Pedro		2972.01	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	33.72274	-118.29035	PV2 FOR 4 UNIT DWELLING PLAN CHECK ONLY. EXPRESS PERMIT WAS PULLED UNDER THE APPLICATION#: 12041-20000-25375. 5.0 KW SYSTEM 14 MODULES AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50371	16041-30000-13057	9039 N WHITAKER AVE	91343	12	195B133    16	2688025032	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.23501	-118.49925	Plan check for PV roof mounted system. system size: 10kW with 35 modules and 1 inverter(10kW solar edge). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50372	12041-10000-03716	1601 N CAHUENGA BLVD	90028	13	148-5A187 317	5546007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM			PC Approved	02/17/2012 12:00:00 AM	ADDRESS	34.09987	-118.32967	title 24 , e lites, 1st floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50373	16041-20001-04867	4633 N CANOGA AVE	91364	3	166-5A107  10	2190016006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.15254	-118.59593	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Addition of a 6 kWac system onto an existing 5 kWac for a total system size of 11 kWac. Addition consists of (1) inverter, (30) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50374	19041-10001-15355	6316 N TOPANGA CANYON BLVD	91367	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Issued	08/02/2019 12:00:00 AM	ADDRESS	34.18578	-118.60514	Changes to an approved set of plans. All changes are clouded under delta 8. Changes include revising floor plans, emergency photometrics, and revising Title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50375	11041-20000-04685	18700 W VENTURA BLVD #170	91356	3	174B121   811	2161026002	C2-1VL	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Finaled	09/09/2011 12:00:00 AM	ADDRESS	34.17045	-118.54081	PLAN CHECK POWER AND ENERGY FIRST TIME TENANT TO SHELL BUILDING T.J. MAXX RETAIL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50376	14041-20001-00726	8416 N TYRONE AVE	91402	6	192B153   452	2638024021	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.22388	-118.44419	EXPEDITE FEES ONLY.        <<<New rooftop mounted PV system for an existing single family dwelling.  System is UNGROUNDED.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50377	18041-10002-47136	611 E FLOWER AVE	90291	11	111B145   985	4240011022	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	33.99867	-118.4709	Changes to approved set, scope of work includes upsizing the central inverter to SE3800H-US, and addiding five modules (SC325) with optimzers (SE P400)Orginal Scope(PV1 ROOFTOP SOLAR SYSTEM ON (E) SFD, INSTALL 13.5 KWH ENERGY STORAGE SYSTEM AND 3.25 KWDC PV ARRAY, WITH 10 MODULES(SC SC325), AND 1 INVERTER(UNO-DM-3.3-TL-PLUS-US-SZ).)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50378	18041-20001-17807	3144 N CORDA DR	90049	11	159B137   486	4490004049	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.1296	-118.48812	Expedite per applicant request Plan check for PV roof mounted system, system size: 19.6kWac with 66 modules and 66 microinverters connected to 400A MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50379	16041-10001-23431	13843 W MILBANK ST	91423	4	168B153   842	2271005003	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.15313	-118.43448	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM FOR AN EXISTING RESIDENTIAL ROOF-TOP. SOLAR SYSTEM INCLUDES BATTERY STORAGE SYSTEM AND AN INVERTER/CHARGER. TOTAL PV SYSTEM SIZE IS 6.45KWac.(30)MODULES-HYUNDAI HIS-S255RG(30)MICROINVERTERS-ENPHASE M215-60-2LL-S22(1)BATTERY STORAGE INVERTER-SCHNEIDER XW-5548  5500W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50380	18041-10000-41671	1080 S LA CIENEGA BLVD	90035	5	132B173   684	5087001038	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Issued	10/31/2018 12:00:00 AM	ADDRESS	34.05713	-118.37597	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50381	16041-10000-23894	12249 W VENICE BLVD	90066	11	114B153  1302	4248031002	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	06/24/2018 12:00:00 AM	ADDRESS	34.00466	-118.43212	T-24, PC FOR ENERGY ONLY. Change of use from existing pool hall and bar to new restaurant.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2700 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50382	18041-10000-20108	6325 W SANTA MONICA BLVD 1st & 2nd-floors	90038	13	144B185   700	5533007036	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.09087	-118.32754	INTERIOR T.I. : NEW KITCHEN SPACE on 1st floor ; 2ND FLOOR OFFICE SPACE,.plan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50383	14041-10000-22540	13625 W VENTURA BLVD	91423	4	165B157   627	2360006028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.14804	-118.43036	TENANT SPACE WAS ONCE A RESTAURANR;NEW TENANT REEMODELED AND KEPT THE TENANT SPACE AS A RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50384	09041-10001-06294	1377 N SERRANO AVE 3rd floor	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM			PC Approved	01/06/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	revisions to approved Title 24 energy plan chk appproval- removed T-bar ceiling in the corridor which will remain unconditioned space and added strip luminaires . no changes in the equipment roomplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50385	10041-20000-13603	6090 W PICO BLVD	90035	10	129B173   256	5068002001	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	08/26/2010 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.05263	-118.37368	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE/OCCUPANCY  FROM RETAIL TO SYNAGOGUE (PLACE ASSEMBLY).  EXISTING 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50386	15041-10000-11978	13020 W PACIFIC PROMENADE UNIT 7	90094	11	102B157   226	4211029***	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	33.97287	-118.42296	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1082	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50387	19041-20000-43575	9784 W SUFFOLK DR	90210	5	159B157   282	4385006057	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.12866	-118.42948	Plan check for Energy Storage System installed into existing PV system, Energy Storage System size: 40.5KWh. 3 Tesla PowerWall 2.0, 1 sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50388	12041-10000-28663	624 S GRAND AVE 2510	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM			PC Approved	12/10/2012 12:00:00 AM	PIN	34.04778206	-118.25563275	T24 FOR EXISTING COMMERCIAL. 25TH FLOOR.812SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50389	18041-20000-29655	6100 W CENTER DR ste 600	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Issued	08/07/2018 12:00:00 AM	ADDRESS	33.97733	-118.3922	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50390	13041-10001-33080	22538 W VANOWEN ST	91307	12	180B097    28	2038027008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.19356	-118.61806	PV1.  Install 4.75 kW roof-mounted PV system, interconnect with main service panel.  19 modules: Trina Solar TSM-250PA05.18.  Transformerless inverter: SolarEdge SE5000A-US.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50391	17041-10000-46679	2750 W COLORADO BLVD	90041	14	163-5A219 154	5682002025	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.14257	-118.22587	Design Build. Energy plan check for a commercial T.I (Massage Parlor). Scope includes new light and existing ckt. Total area is (533) SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50392	13041-20001-35351	3725 N BEVERLY RIDGE DR	91423	4	162B149   454	2274016008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.13853	-118.44734	(((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.8 KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50393	18041-10001-10897	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.17126	-118.58861	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS (CLOUDED UNDER DELTA 3)- CHANGES INCLUDE ADDITION OF FEEDERS FOR VISTA SWITCH AND ADDITION OF NEW BRANCH CIRCUIT.ORIGINAL PERMITPC for power for install of 3.141MW fuel cell system for Kaiser OSHPD building. Installing new switchboards, eight 300kW, one 210kW and two 262.5kW fuel cell units. Fuel cells designed to be used as the primary source of energy for building adnd supplies building through 1500kW and 2500kW transformers. All new equipment to be installed outside the building.B# 18020-10000-00754.INSTALL OF A FUEL CELL GENERATOR WITH CONCRETE PAD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50394	11041-20000-14746	6920 N VAN NUYS BLVD	91405	6	183B149   499	2217009801	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.19604	-118.44846	Installing a new 1000 Amp distribution board for new chillers. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50395	18041-20000-20272	5515 W 104TH ST	90045	11	090B173   269	4129033006	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.94208	-118.37687	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50396	16041-10000-36142	2909 N FLETCHER DR	90065	13	153B209   644	5458002012	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.1142	-118.24722	TITLE 24 ONLY FOR EXISTING LOW-RISE COMMERCIAL BUILDING ROMOVE EXISTING HID FIXTURES AD REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50397	14041-10001-09517	549 S MORENO AVE	90049	11	129B137   606	4264004004	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	34.04641	-118.48747	(((EXPEDITE FEES)))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 10.0KWAC. THESE WERE CHANGES MADE TO APPROVED SET HOWEVER CHANGES ARE >50%. ORIGINAL APPLICATION#: 13041-10000-24969.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50398	18041-30000-02517	2368 W PICO BLVD	90006	1	129B197  1081	5056004007	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.04706	-118.28833	Plan check for new Fire alarm system for office building. Total devices: 82 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50399	14041-20000-12923	1536 N ORANGE GROVE AVE PV 1	90046	4	147B177   781	5551020015	R1-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM			PC Approved	05/14/2014 12:00:00 AM	ADDRESS	34.09913	-118.36034	Roof mounted PV system with Optimizer and transformerless inverter.  System size 5.32KW.Note: Permit and zonning clearance is under 14041-20000-11611	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50400	15041-10000-42408	8856-8858 W PICO BLVD	90035	5	132B169   923	4305014007	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.05485	-118.38504	FULL PC, FOR POWER AND ENERGY.  CHANGE OF USE TO A MARKET AND TAKE OUT RESTAURANT. UPGRADING SERVICE TO 600 AMPS WITH  NEW ELECTRICAL EQUIPMENT. TOTAL SQ. FT. 2,931.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50401	14041-20001-02446	20000 S WESTERN AVE	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	33.85008	-118.30908	PV2 PHOTOVOLTAIC SYSTEM. TOTAL SYSTEM SIZE 930KWAC WITH ISOLATION TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50402	13041-20002-32925	5110 S CRENSHAW BLVD	90043	8	111B185   564	5013019023	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	33.99629	-118.33046	[[[[12/9/15 CHANGES TO APPROVED SET OF PLANS. DELTA 2 CHANGES ONLY, CHANGES HAVE BEEN CLOUDED. CHANGING MAIN SWITCHBOARD FROM FULLY RATED TO 100K SERIES RATED AND PROVIDE FEEDER DWP-1]]]]]][[[[[[10/23/2014     Changes to approves set of plans. Delta 1 changes only. Changing the service from 120/208 to 120/240 three phase four wire. ]]]]]]Plan check for power and energy for a  MULTI-FAMILY APARTMENT COMPLEX WITH 32 UNITS.Variance is been submitted to separate fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50403	12041-20000-11882	10623 W BLOOMFIELD ST	91602	4	165B177   435	2423017018	[Q]R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM	05/23/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.1497	-118.36223	fire alarm 14 units apartments	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50404	18041-10000-36644	11150 W SANTA MONICA BLVD 1020	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLAN CHECK FOR ENERGY ONLY INTERIOR TI IN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1936.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50405	19041-20002-43481	18917 W CARMEL CREST DR	91356	3	162B121   158	2177048010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.14117	-118.54499	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CLOUDED CHANGE ONLY, CHANGE TO ROOF PLAN, RELOCATION OF PV PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50406	17041-10000-43967	889 S FRANCISCO ST	90017	14	129A207   342	5144023***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.04769	-118.26404	PC FOR POWER ONLY FOR 10 TESLA CHARGING STATIONS.  SCOPE INCLUDES 5 SUPERCHARGERS AND TWO 600A 480/277V 3 PHASE 4 WIRE DISTRIBUTION BOARDS. B#17016-10000-36217	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50407	19041-20000-53196	1443 N KINGS ROAD	90069	4	147B173   519	5555013027	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	02/25/2020 12:00:00 AM		Issued	02/25/2020 12:00:00 AM	ADDRESS	34.09644	-118.37289	Plan check for PV roof mounted system, PV System, size: 15.54KW DC, 11.4KWAC with 42 PV Modules and 1 inverter(11.4KW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50408	17041-20000-14335	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Issued	09/25/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for installation of solar carports on roof of existing parking structure (Northridge Fashion Center). 825.9kW ungrounded system. (1992) 365W pv modules. Every two modules are connected to a 730W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50409	19041-10002-13745	5805 W 8TH ST ev2	90036	4	132B177   172	5089010024	R3-1-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.06086	-118.35605	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. CHANGES IN FEEDER SIZE AND BREAKER. <<<addition of (11) EV chargers to an existing service.  plan check for power only.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50410	14041-10000-21985	2173 N MANDEVILLE CANYON ROAD	90049	11	138B133   334	4492003004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.07395	-118.49976	PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(15) MODULES: KYOCERA KD 255GX(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50411	17041-20000-39699	6231 N WILBUR AVE	91335	3	177B121   252	2128010011	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.18362	-118.54508	Plan check for solar pv system, roof-mounted array on SFD.Total system size: 4.6kW ungrounded.(20) EnPhase IQ6 microinverters.(20) 305W pv modules.Using a standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50412	19041-20000-21926	14136 W ATTILLA ROAD	90402	11	123B129   373	4410027002	R1H1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	12/08/2020 12:00:00 AM	ADDRESS	34.03393	-118.51159	PV1.  Install 11.52 kW DC / 10.479 kW AC roof mounted grid tied PV system.  (32) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50413	14041-20000-10779	13361 N GLADSTONE AVE	91342	7	225B153   251	2509001007	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Expired	05/30/2016 12:00:00 AM	ADDRESS	34.31435	-118.43309	Roof mounted PV system with Optimizer, system size 6.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50414	16041-10000-28876	7315 W APPERSON ST	91042	7	204B197   732	2558020019	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.25609	-118.29164	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES TI-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50415	17041-10000-37223	11243 N GLENOAKS BLVD # 108	91331	7	210B161   155	2533018900	OS-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.27438	-118.41276	TENANT IMPROVEMENT TO AN EXISTING MULTI-PURPOSE COMMUNITY CENTER TO PROVIDE TRAINING KITCHEN FOR EDUCATIONAL PURPOSES.  NO COMMERCIAL SALES OF PRODUCTS PRODUCED IN TRAINING KITCHEN IS PERMITTED.  PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50416	19041-10000-01066	610 E 59TH ST	90001	9	105B205   172	6007005001	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.98705	-118.26446	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50417	17041-10000-19430	16320 W ROSCOE BLVD	91406	6	192B137   317	2689023001	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.22111	-118.48785	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50418	17041-10000-43733	20955 W DE MINA ST	91364	3	171B109   418	2167016017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Issued	12/19/2017 12:00:00 AM	ADDRESS	34.16121	-118.59026	Installing new 10kWh lithium storage battery  in SFD and upgrading main panel 225A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50419	19041-10000-12545	360 N SKYEWIAY ROAD	90049	11	135B141   574	4403015006	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.06508	-118.48112	Install roof mounted Solar system that consist of 1 inverte,10 Modules and 10 optimizerts @ 3.05KWdc amd 3KWac & 1 ESS @ 13.5KWH.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50420	11041-10000-21699	5200 W CENTURY BLVD ste 380	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			Corrections Issued	10/12/2011 12:00:00 AM	ADDRESS	33.94516	-118.37049	T.I. to an existing office building.  No Emergency lights per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50421	18041-30000-24261	767 N HILL ST	90012	1	135A215   327	5408019061	C2-2D	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.06256	-118.23987	POWER & ENERGY PLAN CHECK FOR A CHANGE OF USE FROM OFFICE TO AN EYE CLINIC TENANT IMPROVEMENT. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 1,025 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50422	11041-20000-12023	19831 W NORDHOFF PL #116-#117	91311	12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	06/10/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.23691	-118.56541	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50423	16041-20000-19961	5725 S ST ANDREWS PL	90062	8	108B193  1136	5005023020	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/23/2016 12:00:00 AM	ADDRESS	33.99021	-118.31148	PV1.  Install 3.75 kW roof-mounted PV system.  (13) modules with (1) 3.8 kW rated central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50424	12041-10000-02080	8944 N RUBIO AVE	91343	12	195B137   207	2688020015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.23354	-118.49551	NEW 8.64KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50425	19041-20000-40044	14548 W VENTURA BLVD	91403	4	166-5A151 130	2276001009	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.15103	-118.45038	Tenant improvement in existing retail space, new lighting in stock room in the back of the retail space. Title 24 Energy compliance. Total area: 304 sq ft. B#19016-30000-21603	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50426	17041-10002-38944	1508 N LACHMAN LANE	90272	11	135B121    50	4420035004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.06302	-118.54979	"[[[4/4/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ONLY. CHANGING SUBPANEL ""H"" MAIN BREAKER TO 200 AMPS]]]NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PV1, SOLAR ROOF MOUNTED SYSTEM USING TWO CENTRAL INVERTERS WITH (43) MODULES, (1) 5.2 INVERTER, (1) 6.6 INVERTER,  AND 125A LOAD CENTER. TOTAL PV SYSTEM SIZE IS 11.8KWac."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50427	12041-10001-25835	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.0754	-118.38272	Lab renovation work relocated to different lab space.  No new lighting in this lab space.  Revision tags C1, D1, D2, D3.  Original plan check by M.Z. 08/29/2013(((PLAN CHECK POWER AND ENERGY FOR T. I. OF EXISTING MEDICAL RESEARCH LABORATORIES   ON THE FIRST & THIRD FLOORS. NEW PANEL BOARD, LIGHTING,  CIRCUITS, AND ELECTRICAL DEVICES)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50428	13041-20000-09130	400 S HOPE ST flr 25-flr 26	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for energy and emergency lighting. restrooms for 25th and 26th floors. commercial high-rise. CBRE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50429	17041-20001-11436	400 N BRISTOL AVE	90049	11	135B137   617	4405017010	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.06274	-118.48842	04-19-2018 Changes to an approved set of plan. Changes include revised  panel C and reduced main breaker size from 250A to 200A and reduced conductor size feeding panel C. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50430	16041-10000-06374	222 S OXFORD AVE	90004	10	138B193  1427	5517008023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			Corrections Issued	02/23/2016 12:00:00 AM	ADDRESS	34.07046	-118.30775	CHANGE OF USE FROM OFFICE/DWELLING UNIT TO DAYCARE CENTER WITH (E) 200MSA. PC FOR ENERGY ONLY, TOTAL AREA 1,899SQ.FT (INDOOR) AND 2,120SQ.FT (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50431	17041-30000-40731	101 S LA BREA AVE	90036	5	138B181   853	5513019042	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.07338	-118.34425	Plan check for Title 24 only in existing space office T.I. Total area: 3,805 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50432	13041-10001-22301	5409 N ALDEA AVE	91316	5	174B133   817	2258001025	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.16941	-118.50819	EXPEDITED PLAN CHECK PER APPLICANT REQUEST.(((PV1.  INSTALL 11.5 KW AC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT INTO UPGRADED MAIN SERVICE PANEL (NEW PANEL UNDER SEPARATE EXPRESS PERMIT))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50433	11041-10000-27398	2430 E 11TH ST	90021	14	120A217    70	5168003008	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	ADDRESS	34.02355	-118.22911	AT EXISTING PRINT SHOP, UPGRADE SERVICE TO ACCOMODATE NEW PRINTERS AND ASSOCIATED EQUIPMENT; ORIGINALLY, BUILDING HAD 2 SERVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50434	12041-10001-27648	415 S LA BREA AVE	90036	4	135B181   536	5508006028	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.06635	-118.34436	((((CHANGES MADE TO APPROVED SET OF PLANS. UPGRADING SERVICE FROM 1600 A TO 2000 A. UPGRADING THE FEEDERS AND PANELBOARD/SWITCH BOARDS)))))T24 PLANS WERE ADDED TO OTHER SET OF PLANS 11/28/12Construct 1-level retail below roof top parking deck.  New service, panels, circuits, outdoor and indoor lighting. EPC is for power and energy. (T24 calc. not included @ the submittal, applicant will bring it later)SHELL ONLY; EXCEPT FOR ELEVATORS AND HOUSE PNEL, CONDUITS FOR FUTURE TENANT SPACES ARE STUB-UP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50435	15041-10000-24067	1500 W PACIFIC COAST HWY Bldg H	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 36 unit apartment with garage, 100 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50436	19041-10000-14327	777 S FIGUEROA ST 43RD FLR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Energy plan check for an office TI located in the 43th floor of a high rise building. Scope includes new lighting and equipment with a total area of 7,517-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50437	14041-20000-25452	21301 W BURBANK BLVD 3RD FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.17351	-118.59524	TI FOR FULL 3RD FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50438	17041-10000-02755	1115 N WILCOX PL	90038	13	144B185   660	5533010017	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.09134	-118.33164	Plan check for Title 24 only indoor and outdoor in existing space, remove HID fixtues and replace with new LED lighting fixtures. Total indoor and outdoor area: 6,450 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50439	19041-10000-35189	800 S LA BREA AVE	90036	4	132B181   271	5084003001	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.06027	-118.34454	NEW FIRE ALARM SYSTEM IN A BREWERY. SCOPE INCLUDES NEW FA PANEL, COMMUNICATOR,  POWER SUPPLY AND 16 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50440	13041-10000-11255	9647 N CEDROS AVE	91402	7	201B149   572	2650018011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.24554	-118.45285	PV1 MICRO INVERTER SINGLE STORY HOUSE. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: solarworld sw 270 mono]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50441	12041-20000-12390	6420 W WILSHIRE BLVD 1920	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I. ENERGY Existing permit permit for relocation of 6 circuits. 12041-20000-11080	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50442	16041-20000-03352	21606 W BLACKHAWK ST	91311	12	204B105   192	2722009013	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Expired	03/07/2018 12:00:00 AM	ADDRESS	34.25821	-118.60013	Plan check for a PV1 roof-mounted PV system. System size is 7.2 kWac and consists of (2) inverters, (28) modules, (2) combiner boxes, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50443	11041-10001-18110	11659 W SANTA MONICA BLVD	90025	11	126B149   212	4262002015	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.04421	-118.45548	Modification to previously approved set of plans for clouded areas only.  Removed a panel for the sushi restaurant.  Sushi Rest. will be served by only one meter.  New transformer to serve the single phase portion of restaruant and added new panels<<<<change of switch gear from outdoor to indoor>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50444	14041-20000-17118	19712 W ANADALE DR	91356	3	162B117   203	2180013009	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.14093	-118.56269	8.4KW PV1roof-mounted system with (30) Sunmodule Plus SW280 modules and Enphase M250 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50445	17041-20003-30167	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	06/01/2018 12:00:00 AM	ADDRESS	34.21445	-118.48429	06/01/2018 Changes to approved set of plans. Changes are noted under delta 3 which include upsizing on feeder schedule05-25-2018 Changes to an approved set of plan, Changes include remove part of the carport from plan. All changes has been clouded. Plan chcek only************************Provious Work description***************************Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size is 400 kWac. Ground-mounted portion of the system is 124 kWac and consists of (3) inverters, (404) modules, and (1) load centers.Note: Building permits for the ground-mounted carport system have been issued under building permits 17010-30000-03239/03464/03465. Roof-mounted portion of the system has application number 17041-20000-30164.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50446	17041-10000-38018	10990 W WILSHIRE BLVD 4TH FL	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.0577	-118.44711	NEW LUMINAIRES IN RESTROOMSPLAN CHECK IS FOR TITLE 24PERMIT WAS OBTAINED SEPARATELY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50447	13041-10000-28121	5019 N WILLOW CREST AVE	91601	2	171B177  1170	2419014016	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Expired	11/03/2015 12:00:00 AM	ADDRESS	34.16181	-118.36282	PV1, ROOF-MOUNTED SOLAR INSTALLATION ON A MICROINVERTER STANDARD PLAN. SYSTEM SIZE IS 4.320 KW AC. M215-60-2LL-S22 MICROINVERTER WITH 20 MODULES (REC 250PE) .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50448	18041-10000-36835	101 S THE GROVE DR	90036	4	138B177  1131	5512003038	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	10/22/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.07256	-118.35874	FULL PLAN CHECK FOR TENANT IMPROVEMENT OF EXISTING THEATER TO REMODEL CONCESSION STANDS. NEW LOADS WILL BE FED FROM EXISTING PANELS, TOTAL AREA UNDER THE SCOPE: 652 SQ.FT(B# 18016-30000-23459)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50449	14041-10000-33745	13210 W DEBELL ST	91331	6	198B157   516	2625006003	RS-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Expired	12/30/2016 12:00:00 AM	ADDRESS	34.23895	-118.42061	Installation of a PV1 roof-mounted PV system. System consists of (1) inverter, (1) combiner, and (31) modules. System size is 6 kWac. FEE AMOUNT REFLECT ON SENATE 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50450	15041-10000-04962	11175 W SANTA MONICA BLVD 6TH FLOOR	90025	5	129B149   297	4324035029	M1-2	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.04739	-118.44609	Title 24 plan check only.  Total area = 10,806 sq. ft.T.I. to existing office space including new lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50451	15041-20000-15363	1840 S CENTURY PARK EAST Suite 300	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.06188	-118.41473	Title 24 plan check only.  Total area = 10,219 sq. ft.  T.I. to existing highrise commercial office space.  Installation of two new panels, one new transformer, and alterations to three other panels.  New load is less than 400 A.  New lighting and recpeticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50452	19041-20000-06863	8700 S PERSHING DR PV5	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	04/18/2021 12:00:00 AM	ADDRESS	33.95471	-118.44097	PV2.  Install 71.18 kW DC / 65.04 kW AC roof mounted grid tied PV system.  (195) modules with (2) 33.3 kW rated string inverter.  Interconnecting with MSA-5.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50453	17041-10000-35375	9841 N AIRPORT BLVD	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.94647	-118.38626	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM OFFICE TO DOCTOR'S OFFICE AT GROUND FLOOR OF AN EXISTING COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS 9646 SQ. FT  B#17016-10000-17101	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50454	15041-10000-04399	8053 W 3RD ST SUITE A	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.07217	-118.36505	PLAN CHECK FOR ENERGY FOR RETAIL SPACE. TOTAL NEW LOAD DOES NOT EXCEED 400 AMPS. NOT A FIRST TIME TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50455	19041-20000-05624	20283 W LORENZANA DR	91364	3	171B113   274	2166041010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.16426	-118.57576	Plan check for a PV1 roof-mounted PV system. System size is 9 kWdc/8.1 kWac-CEC and consists of (1) 7.6 kWac-rated inverter and (30) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50456	19041-10001-33011	888 S FIGUEROA ST # 700	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	34.0465	-118.26225	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE RELOCATION OF THE FLOOR PLAN TO INCLUDE HALL WAYS. ____________________________________________TENANT IMPROVEMENT IN OFFICES-NEW PANEL BOARD AND CKTS AND LIGHTINGPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50457	18041-30000-43853	6150 N LAUREL CANYON BLVD	91606	2	177B165  1100			South Valley	NORTH HOLLYWOOD VALLEY VILLAGE			1239.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	07/03/2019 12:00:00 AM		Issued	07/03/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	"***SEEE APPLICATION NOTES*****PC FOR POWER AND ENERGY FOR A NEW ""TRADERS JOE'S"" IN A  SHELL SPACE. SCOPE INCLUDES NEW 800 A DISTRIBUTION SECTION 277/480 3PH, PANELS, EQUIPMENT AND CIRCUITS. TOTAL AFFECTED AREA 15920 SQ.FT INDOOR AND OUTDOOR   B#18016-30000-36766"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50458	14041-10000-08559	12548 W WOODBINE ST	90066	11	114B153   309	4247027030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.01097	-118.44199	PV1 ROOF MOUNTED MICROINVETER STANDARD PLAN. TOTAL SYSTEM SIZE 5.184KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50459	19041-20001-00997	20851-20853 N SHERMAN WAY	91306	3	183B109    62	2113013038	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	PIN	34.20136408	-118.5880133	PLAN CHECK ONLY, SUPPLEMENTAL CHANGE TO APPROVED SET. MINOR RELOCATION OF SERVICE EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50460	18041-20000-23643	7215 W WARING AVE	90046	5	141B181   259	5525002038	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Issued	08/23/2018 12:00:00 AM	ADDRESS	34.08537	-118.34667	Plan check for a PV2 roof-mounted PV system. System size is 34.56 kWdc/31.47 kWac-CEC and consists of (2) 14.4 kWac rated inverters, (96) modules, and (1) load center.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50461	15041-10000-41716	9201 N OAKDALE AVE 1st Flr	91311	12	198B113   214	2761001084	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.2381	-118.56706	Energy plan check for an office T.I located in the 1st floor of a commercial building. Scope includes new lighting and receptacle for (2) new office and a breakroom. Total area is 1208-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50462	19041-20000-44289	5256 N MT ROYAL DR	90041	14	163-5A225 124	5669018027	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	11/19/2020 12:00:00 AM	ADDRESS	34.14295	-118.20348	$0 fee per AB1414PLAN CHECK FOR NEW PV SYSTEM AND ESS. PV SYSTEM SIZE IS 18.48 KW/17.02 KW AC CEC. ESSS SIZE IS 26.4 KWH. SCOPE OF WORK CONSISTS OF (56) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, (3) SUB PANELS, AND (2) BATTERIES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50463	10041-20000-09133	145 N LA BREA AVE A-F	90036	5	138B181   632	5513002010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	02/16/2012 12:00:00 AM	ADDRESS	34.07488	-118.34438	PV SYSTEM ON ROOF OF COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50464	16041-20001-30477	17242 W PRAIRIE ST	91325	12	198B133   305	2692005008	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			PC Approved	09/26/2016 12:00:00 AM	ADDRESS	34.23932	-118.51023	Expedited plan check fee per applicant request.  PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.350 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50465	19041-10000-37604	837 W 82ND ST	90044	8	099B197  1154	6032006021	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Apartment			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	08/03/2021 12:00:00 AM	ADDRESS	33.96438	-118.2885	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS ONE NEW FIRE ALARM PANEL AND 57 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50466	16041-20001-43349	19548 W BALLINGER ST	91324	12	198B117    25	2761038009	RE15-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM			PC Approved	12/19/2016 12:00:00 AM	ADDRESS	34.24327	-118.55991	Expedited plan check per applicant request.  PV1.  Install 11.06 kW roof mounted grid tied PV system.  (33) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50467	15041-10001-17994	1026 S BROADWAY BLDG A	90015	14	126A209    92	5139014017	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM	ADDRESS	34.04029	-118.25788	NEW DESIGN.  Changes during verification; all changes include new modules, inverters, and sub load centers. permit shall be under original plan check. supplemental application is for plan check only. original plan checker J.H(((PV2, ROOF MOUNTED SOLAR SYSTEM TO AN APARTMENT BUILDING TOTAL SIZE 155KW. ( 598) MODULES INNOTECH ECO PLUS POLY-UP260.(2) PV INVERTERS SOLECTRIA PV1 75KW-PE)))Permit pulled under master application 15041-10000-17994	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50468	19041-10000-26099	5845 N SERRANIA AVE	91367	3	177B109   196	2149018005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.17739	-118.58854	PV1. Install 7.695 kWDC/6.54KWAC roof mounted grid tied PV system.  (27) modules with P320 OPTIMIZERS, (1) 7.6 KW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50469	18041-10000-05887	4005 W FOOTHILL BLVD	91214	2	198B205   222	2571006021	OS-1XL PER CITY PLANNING	North Valley				1013.00	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Issued	02/16/2018 12:00:00 AM	PIN	34.2408291	-118.2662085	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50470	12041-20000-15243	951 W VERNON AVE 1-16	90037	9	111B197    88	5020035013	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Apartment			06/29/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.00382	-118.2902	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50471	15041-10002-13995	4816 W FOUNTAIN AVE	90029	13	147B197  1139	5540015017	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM			PC Approved	09/10/2015 12:00:00 AM	ADDRESS	34.09524	-118.29387	THIS SUPLEMENTAL IS ISSUED BASED ON THE DEPARTMENT EEROR ON THE ORIGINAL APP PERMIT THAT HAS TO BE FIXEED THIS WAY: 600 A SERVICE INSTEAD OF 800A.[[[[[MAIN SERVICE UPGRADE, 800AMP, TO (E) BUILDING.  PC FOR POWERORIGINAL PLAN WAS APPROVED FOR 400 AMP SERVICE.  PANELS AND CIRCUITS ARE EXISTING TO REMAIN]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50472	17041-10000-37205	11550 W VENTURA BLVD	91604	2	162B169   593	2369035036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.13977	-118.38378	REPLACING INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50473	19041-10000-26330	12044 W ROSCOE BLVD 2100	91605	6	192B165   505	2310001031	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM			PC Info Complete	09/16/2019 12:00:00 AM	ADDRESS	34.22143	-118.39583	PC for T24 only in an exisitng restaurant. Scope of work incldues new lighting, controls, no new circuits. Total affected area is 2834 sqft both indoor and outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50474	18041-10000-24906	950 W 190TH ST	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	33.85814	-118.29219	PC FOR ENERGY ONLY, TENANT IMPROVEMENT OF (E) OFFICE SPACE, NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1728	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50475	13041-10000-33211	8500 W BEVERLY BLVD # 696	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I. REMODEL (E) RETAIL SPACE INCLUDING CEILING, DOORS, PARTITIONS, FIXTURES, FINISHES, ETC.  DOWNSIZE/REMODEL.  3,005 SQFT.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50476	15041-10000-14012	969 S HILGARD AVE 1-145	90024	5	135B153   657	4360001***	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Expired	08/18/2017 12:00:00 AM	ADDRESS	34.0621	-118.44187	(N) fire alarm system with 210 devices and one power supply and control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50477	16041-10000-45543	1585 S RIO VISTA AVE	90023	14	120A219    54	5169010011	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.02116	-118.22117	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50478	15041-20000-14407	12744 N SAN FERNANDO ROAD Bldg #2	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check for Title 24 only. Project site is an existing commercial space; change of use from office to office/warehouse. Project scope is a tenant improvement. Total indoor lighting area = 38,600 sq. ft. and total outdoor lighting area = 715 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50479	11041-20000-01833	13561 W VAN NUYS BLVD	91331	7	207B157   989	2619026006	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM			PC Info Complete	01/31/2011 12:00:00 AM	ADDRESS	34.26147	-118.42883	PLAN CHECK T24 ENERGY FOR CHANGE OF USE FROM OFFICE TO TAKE OUT ICE-CREAM SHOP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50480	16041-20000-04194	10835 N ARLETA AVE	91345	7	207B149   147	2615025011	RA-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	03/12/2016 12:00:00 AM	ADDRESS	34.26695	-118.45134	PV1.  Install 5 kW AC roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50481	15041-20000-06667	1079 N CARRARA PL	90049	11	141B137   217	4493018045	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	34.07901	-118.49114	Fee is $0.00 due to 2012 State Senate Bill 1222.PV1 SFD. TOTAL SYSTEM SIZE 13.6KW AC USING 2 CENTRAL INVERTER SYSTEMS. SYSTEM USES POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50482	19041-10000-30550	17601 S DENVER AVE	90248	15	063B201   105	7339007016	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM			Corrections Issued	08/06/2019 12:00:00 AM	ADDRESS	33.87066	-118.28305	ENERGY PC ONLY FOR CHANGE OF USE FROM OFFICE TO RETAIL. AREA OF SCOPE 5853SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50483	10041-10000-13045	8500 W BEVERLY BLVD # 739	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT OF AN (E) 3929 SF RETAIL SPACE; PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50484	13041-20000-22651	9301 N TAMPA AVE #34	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	New Track Lighting in an existing JCPEnny Store.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50485	16041-20000-16865	12004 N STONE GATE WAY	91326	12	217-5A115  86	2701018012	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.29101	-118.56635	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (27) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50486	16041-10000-13654	762-788 S KOHLER ST	90021	14	124-5A213 244	5146006006	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Expired	05/24/2018 12:00:00 AM	ADDRESS	34.03587	-118.24383	TI to an (E) commercial build. install light fixtures on the outdoor canopy.  PC for T-24 only. Total area: 2,424 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50487	14041-20003-35890	7887 N CLAYBECK AVE	91352	2	189B181   313	2405015015	R2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.05	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.214	-118.35227	05-28-2015. Change to approve set of plan. Changes include change to the layout of modules and inverter [[[[[PV1 SFD. TOTAL SYSTEM SIZE 7.5KW AC USING TRANSFORMED INVERTER. NONSTANDARD PLAN. USING 4 STRINGS.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50488	18041-10002-16194	23115 W SHERMAN PL	91307	12	183B097    55	2021014044	CR-1VL, P-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM			PC Approved	05/09/2018 12:00:00 AM	ADDRESS	34.20115	-118.63061	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES CHANGING THE FACP AND INITIATION DEVICES .  ALL CHANGES MARKED UNDER DELTA 1. NO NEW DEVICES ADDED. THIS IS PALN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50489	13041-20000-26363	10655 N VANALDEN AVE	91326	12	207B121   398	2728002026	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.26436	-118.54986	PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZER 7.3 KW AC USING 34 MODULES. USING ENPHASE MICROINVERTER. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50490	18041-10000-14980	1231 N SPRING ST	0	1	135A215   169	5414014001	C2-2, [Q]C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	PIN	34.06461924	-118.23604048	FULL PLAN CHECK, CHANGE OF USE FROM MANUFACTURING TO RETAIL/OFFICE AND RESTAURANT BUILDING.  SCOPE INCLUDES A NEW 2000A 480/277V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW HOUSE PANELS, AND NEW CIRCUITS. B#14016-10000-03788	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50491	17041-20000-18806	8300 S VERMONT AVE	90044	8	099B197  1482	6032009916	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	33.96338	-118.29134	Plan check for power only. Install 20 EVSE for commercial parking garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50492	15041-20000-24486	7727 N CORBIN AVE	91306	3	189B117  1030	2106012107	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.21151	-118.56251	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50493	19041-10000-02716	8530 N VISBY PL	91352	2	192B177   150	2404028043	RE15-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.22555	-118.3572	NEW PV GROUND MOUNTED SYSTEM. TOTAL SYTEM SIZE IS 5.76KWdc / 3.80KWac.(16)MODULES-HYUNDAI HIS-S360RI(16)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE3800H-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50494	12041-20000-02462	4403 N PORTICO PL	91316	5	165B133   141	2292001018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2012 12:00:00 AM			PC Approved	02/06/2012 12:00:00 AM	ADDRESS	34.15093	-118.50653	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM with line side connection.  Existing permits # 11041-20000-24304 for service upgrade, and 11041-20000-19199 for photovoltaic system equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50495	18041-10000-32275	6262 N VAN NUYS BLVD	91401	6	178-5A151 200	2240003907	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Issued	11/07/2018 12:00:00 AM	ADDRESS	34.18408	-118.44846	Plan check for a fire alarm system located in a commerical building with (1) fire alarm panel, (12) power supplies, and (363) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50496	16041-30000-28620	1153 S SANTEE ST	90015	14	124-5A209  66	5145021028	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.03654	-118.25728	Plan check Title 24 only in existing building. Total area: 350 sq ft.Note: Permit paid under PCIS#16041-10000-22094 (Changes to an approved set of plans. changes include going from a digital system to an analog control system).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50497	10041-20000-20187	605 S PACIFIC AVE	90731	15	015B197   387	7451037028	[Q]C2-1XL-CDO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	07/05/2011 12:00:00 AM	ADDRESS	33.73852	-118.28808	T.I. to existing space.  Install indoor general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50498	16041-10000-15594	1800 N ARGYLE AVE	90028	13	150A189   301	5546033015	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.10384	-118.32506	Installation of a new Fire Alarm system to a new highrise bulding (15 story hotel). FA panels: 1, Communication panels: 1. Fire alarm Devices : 760.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50499	13041-20000-35798	2450 N GLENDALE BLVD A	90039	13	148-5A209 232	5440002009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Info Complete	02/27/2014 12:00:00 AM	ADDRESS	34.10159	-118.25902	800A SERVICE UPGRADE TO EXISTING BUILDING. ADDING SOME NEW LOAD AND UPGRADING HVAC. REPLACING ALL PANEL BOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50500	13041-20000-03237	13287 N RALSTON AVE 2nd floor	91342	7	225B141   172	2501002027	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.31289	-118.47324	Plan check for energy and emergency lighting. 2nd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50501	11041-20000-04398	257 N TRANQUILLO ROAD	90272	11	126B117    62	4416016069	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.04442	-118.56227	PLAN CHECK FOR NEW ROOF MOUNTED 11.28KW PHOTOVOLTAIC SYSTEM ON SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50502	14041-10000-19058	229 N LARCHMONT BLVD	90004	4	138B189   553	5515018017	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM			PC Approved	07/16/2014 12:00:00 AM	ADDRESS	34.07551	-118.32389	PC FOR ENERGY. TI. NO CHANGE OF USE. ONE FLOOR REAL STATE OFFICE. TOTAL AREA 2006 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50503	15041-20000-06624	13417 W KITTRIDGE ST	91401	2	180B157   453	2329018018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Expired	04/06/2017 12:00:00 AM	ADDRESS	34.19041	-118.42528	Plan check for PV system roof top mounted with 4.0kW micor-inverter with 18 modules.Note: Plan submit over the counter becasue fail inspection due to online permits. Failed multiple job b/c of online permits.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50504	18041-20000-46235	550 S WITMER ST	90017	1	132A207   193	5153022009	CW	Central	Westlake	Westlake North		2091.03	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM			Verifications in Progress	01/18/2019 12:00:00 AM	ADDRESS	34.0558	-118.26528	Plan check for a PV2 roof-mounted PV system. System size is 19.44 kWdc/16.52 kWac-CEC and consists of (2) inverters, (54) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50505	19041-20000-28061	19602 W CITRUS RIDGE DR	91356	3	171B117   572	2175040004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM			Reviewed by Supervisor	08/29/2019 12:00:00 AM	ADDRESS	34.16219	-118.56065	PV1.  Install 46.08 kW DC / 40.6 kW AC roof and ground-mounted PV system interconnecting with 600A 240/120V 1ph-3w service.  (128) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50506	17041-10000-33212	2001 E 103RD ST	90002	15	091-5A215 121	6046021001	A1(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	05/30/2020 12:00:00 AM	ADDRESS	33.94325	-118.23651	Plan check for power and energy of new Community Education Center, Barn, Mastergardener Center. Total area: 44,220. Application 3 of 3 This permit covers panel B.Note: 3 Buildings supply by 1 Service(800A). There are 3 electrical application with 1 plan. Building application number: 17010-10000-02863	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50507	15041-10000-24451	2800 VIA CABRILLO MARINA	90731	15	009B197  1289	7440040906	PF-1XL	Harbor	San Pedro	Coastal San Pedro		2976.01	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	PIN	33.71792061	-118.28760715	PC AT COUNTER FOR ENERGY ONLY, T-24. SMALL RENOVATION FOR A (3) STORY HOTEL.SCOPE OF WORK INCLUDES NEW LIGHTING FOR RECEPTION, GIFT SHOP, LOBBY, WAITING AREA, FOYER, PARTY ROOM, AND BUFFET AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50508	10041-20000-08534	440 N CORONADO ST	90026	13	138A205    52	5157005001	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM			Corrections Issued	06/10/2010 12:00:00 AM	ADDRESS	34.07397	-118.27221	ROOF MOUNTED PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50509	11041-10000-08268	916 N WESTERN AVE	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	06/24/2011 12:00:00 AM	ADDRESS	33.75076	-118.30886	T.I.  NEW LIGHTING FOR EXISTING PARKING LOT.  TITLE 24 PLAN CHECK ONLY. (APPLICATION 2 OF 2, BUILDING LIGHTING IS UNDER APPLICATION # 11041-10000-08274)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50510	15041-20000-37727	18209 W PARTHENIA ST	91325	12	195B125   794	2769019041	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Issued	12/11/2015 12:00:00 AM	ADDRESS	34.2289	-118.52978	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERICAL ROOF-TOP. TOTAL SYSTEM SIZE IS 79.12KWdc/80.0KWac. (344) MODULES-SCHUCO MPE-230W (4) INVERTERS-GROWATT 20,000-UE (240V)(1) 200A SUBPANELNOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50511	10041-20000-15100	9157 N DE SOTO AVE	91311	12	198B109   148	2746009022	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM			PC Info Complete	01/31/2011 12:00:00 AM	ADDRESS	34.23726	-118.5888	PLAN CHECK POWER AND ENERGY FOR NEW RETAIL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50512	17041-10001-37396	3966-3976 W MELROSE AVE	90029	13	142-5A201 288	5539026025	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.08347	-118.28631	PLAN CHECK FOR CHANGES TO APPROVED SET UNDER DELTA #3 - CHANGES INCLUDE REDUCTION OF ONE LIGHT FIXTURE DUE TO CHANGE OF SITE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50513	13041-10002-34488	6320 N TOPANGA CANYON BLVD BLD # G	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Approved	08/06/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	ADDED STORAGE ROOM INCLUDE LUMINAIRE ( LIGHTING DENSITY LESS THAN 0.6W/SF) AND CU UNIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50514	16041-10000-07496	1575 N GOWER ST	90028	13	148-5A189 330	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	FULL PC, SIX FULL FLOORS OF INTERIOR TENANT IMPROVEMENT AND ONE ROOFDECK PATIO ENTIRE IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. WORK BEING DONE ARE IN THE 1ST, 2ND, 5TH, 6TH,  1/2 OF 3RD, AND 4TH FLOOR. TOTAL SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50515	15041-10007-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	34.25734	-118.50614	02-09-2018 Changes to an approved set of plan. Changes include addition of instantaneous Circuit breaker to elevator. Changes include delta only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50516	13041-10000-17162	14654 W NORDHOFF ST	91402	6	198B149   579	2651011005	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Apartment			06/27/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.23522	-118.45198	New fire alarm system for 4 story apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50517	16041-20001-19818	530 S CATALINA ST	90020	10	135B197   887	5502022017	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.06453	-118.29524	PV2.  Install 25.84 kW DC roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50518	11041-10000-23075	5600 W SUNSET BLVD	90028	13	147A193   109	5544029032	(Q)C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Expired	12/16/2015 12:00:00 AM	ADDRESS	34.09792	-118.3112	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50519	13041-10000-27448	1826 W COLORADO BLVD A-B	90041	14	162A225   127	5686009001	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/04/2013 12:00:00 AM	ADDRESS	34.13901	-118.2071	Remove HID light fixtures and install new fluorescent fixtures in a warehouse building.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50520	14041-10000-24938	13415 W BLYTHE ST	91402	6	189B157   437	2301020014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Expired	11/01/2016 12:00:00 AM	ADDRESS	34.21501	-118.42545	PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50521	19041-10000-04268	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR TITLE 24 ONLY FOR - T.I. to existing anchor building. - TOTAL AFFECTED AREA = 1605 SF. (TAILOR METHOD)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50522	18041-20001-45012	24214 S STERLING RANCH ROAD	91304	12	192B089   198	2017039009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.21939	-118.65454	change of address	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50523	16041-10000-40602	11120 W CHANDLER BLVD Build. 2	91601	2	171B173   257	2350015036	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Issued	03/10/2017 12:00:00 AM	ADDRESS	34.168	-118.37317	5 STORY MIXED USE, 106 RESIDENTIAL UNITS WITH 8-TYPICAL. PC FOR POWER AND ENERGY. NEW 2000A SERVICE  AND PRIVATE METER RESIDENTIAL UNITS. . TOTAL AREA INDOOR AND OUTDOOR: 122,538 SQ FT.B# 16010-10000-00103	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50524	14041-10000-00754	777 E 12TH ST #1-2	90021	14	123A211    59	5132010036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.03264	-118.25093	Remove HID light fixtures and replace with new fluorescent fixtures in retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50525	12041-20000-28848	5410 E HUNTINGTON DR SOUTH	90032	14	145-5A237 271	5219033023	RD1.5-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.09121	-118.16328	New rooftop mounted photovoltaic system for an existing duplex.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50526	14041-20002-21443	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			12/16/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.19603	-118.45077	12/16/2015 Changes to an approved set of plans. All changes have been clouded and marked as Delta E. Changes include the change of use of (1) of the aparment units to an office. Title 24 for the new office have been included.*****Previous Work Description*****12/03/15Changes to an approved set. All changes made under delta D. Scope includes adding a new panel/feeder to the main distribution panel. Going from a 49 unit apartment building to 50 unit apartment building. (((Plan check for power and energy (2008 Energy Code). New 49-unit apartment building, 3-stories. Fee calcs provided by applicant - verify. Fire alarm variance filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50527	16041-20000-36135	17551 W MARGATE ST	91316	5	171B129    54	2257003041	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.16774	-118.5159	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20.140 KW.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50528	15041-20000-39140	11937 W COHASSET ST	91605	2	186B165   364	2317011017	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	01/05/2016 12:00:00 AM	ADDRESS	34.20676	-118.39354	PV1, roof mounted solar panel, 10.335kW system(39)modules: #KU2656ZPA(1) inverter: PVI-5000-OUTD-US-Z-A(1) inverter: PVI-3.0-OUTD-S-US-Z-A(1) Load center 125AStandrad plan is used	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50529	14041-10001-25717	7554 W LOLINA LANE	90046	4	156B177   266	5570010041	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			Reviewed by Supervisor	10/07/2014 12:00:00 AM	ADDRESS	34.12432	-118.36112	EXEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 9.945 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(39) MODULES: KYOCERA KD255GX-LFB3(1) INVERTERS: FRONIUS IG PLUS A 7.5>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50530	19041-20000-33277	2554 S VETERAN AVE PV1	90064	5	123B157    67	4256004026	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.03692	-118.42938	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 8.28KW DC/7.245KW AC. SCOPE OF WORK INCLUDES (23) PV MODULES WITH INTEGRATED MICRO INVERTERS, AND A PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50531	19041-10000-10452	4551 S GLENCOE AVE #140	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC T-24 only for office. Scope of work is 2917sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50532	09041-10001-09726	433 S LUCAS AVE	90017	1	132A207   128	5153023013	CW R5(CW)-U/6	Central	Westlake		YES	2091.01, 2092.00	Electrical	Electrical	Apartment			07/29/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	11/19/2010 12:00:00 AM	ADDRESS	34.05665	-118.2629	Change the priviously approved plan. Addition of lights and branch circuits. Plan check for changes. ((((((((((((((PLAN CHECK POWER AND ENERGY FOR  9  UNIT  4  STORIES OVER LEVEL 1 PARKING  (APPLICATION 2 0F 2) VARIANCE TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.  T-24 ENERGY CALCULATIONS ARE COMBINED WITH #09041-10000-09723)))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50533	16041-10000-43806	3201 S HOOVER ST 8-C3	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	T-24, PC FOR ENERGY ONLY. TI FOR A RETAIL SPACE ON THE GROUND FLOOR FOR SUITE 8-C3. SCOPE INLCUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1303 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50534	17041-10000-16751	662 S KELTON AVE	90024	5	135B149   483	4363014009	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			05/18/2017 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	09/02/2020 12:00:00 AM	ADDRESS	34.06503	-118.45264	FULL PC FOR A NEW 12 UNITS  APARTMENT BUILDING. SERVICE SIZE 800AMP. TOTAL AREA OF LIGHTING : 18638 SQ FT.B# 14010-10000-04106	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50535	17041-10000-10812	515 S COLUMBIA AVE	90017	1	132A207    86	5153020001	PF-1XL	Central	Westlake	Westlake North		2091.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.05667	-118.26617	Title 24 only for Interior remodel (non-structural T.I.) of (E) 3-story office building. Total sq. ft. 17124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50536	17041-20000-09081	12700 W VAN NUYS BLVD bldg 19	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM			Reviewed by Supervisor	04/17/2017 12:00:00 AM	ADDRESS	34.27528	-118.4092	pv2install roof mounted pv system (ACM) sized 3.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50537	11041-10000-02634	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM			PC Info Complete	02/10/2011 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI FOR A COFFEE SHOPE KIOSK INSIDE THE SHOPPING MALL. EPC IS FOR T24 & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50538	16041-10001-11352	5854 S 6TH AVE	90043	8	105B189   123	4005017015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM			PC Approved	06/20/2016 12:00:00 AM	ADDRESS	33.98753	-118.32338	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KW.(14)MODULES-AU OPTORONICS #PM250M01_260W(1)INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-APERMIT PULLED PCIS#16041-90000-11352((((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50539	13041-10006-26820	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			10/26/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	33.97574	-118.39042	Change to approved set by changing all main feeders from Copper to Aluminum, service load calculation being   revised and some units load calculation also being updated. All changes are under delta-8 only.(((8/10/2015CHANGE OF ENGINEER.  APPLICANT TO SUBMIT LETTER FROM ORIGINAL ENGINEER/OWNER BEFORE PERMITTING.  PLAN CHECKER TO VERIFY LETTER FOR CHANGE OF ENGINEER BEFORE FINAL APPROVAL OF PLANS.  CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 7. CHANGES INCLUDE REVISIONS TO THE LIGHITNG FIXTURES AND REVISIONS TO THE ENERGY CALCS.New 218-unit apartment building at Howard Hughes Center.  Power and energy.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50540	19041-20000-32292	8412 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50541	10041-10002-23341	5771 W 96TH ST	90045	11	093B169   134	4125021010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Info Complete	10/19/2011 12:00:00 AM	ADDRESS	33.94955	-118.38342	New manufacture. New panel and circuits. EPC is for power and energy. (BLG# 5771) ((((((((((((((((((((((((((((((((((((((addition of 40  amps panel H4 withe two 20 HP and one 150 HP kettle))))))))))))))))))))))))))(   changes made  to previously approved set  10-13-11))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50542	18041-10000-39409	8404 W FOOTHILL BLVD	91040	7	204B189    68	2560006001	C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.25953	-118.31598	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50543	16041-10003-12868	20324 W REAZA PL	91364	3	171B113    68	2166035011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.16798	-118.577	06/30/16Changes to an approved set of plans. Changes include the derating of the main breaker to comply with the pv feedback connection. (((PV1, new solar system on existing residential roof-top. Total system size is  9.0kWac.        (36) Solarworld SW275 mono blk    (36) Microinverters-Enphase Energy M250-60-2LL-S25)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50544	14041-20000-17275	14809 W CALVERT ST	91411	6	178-5A149 295	2241017021	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.18178	-118.45577	TI of light industrial bldg.    Energy plan check for changes to lighting system.  BLDG PERMIT: CHG (E) 3 STORY LIGHT INDUSTRIAL TO 2 STORY WITH MEZZAZINE LIGHT INDUSTRIAL, ADD ELEVATOR SHAFT TO ROOF TOP . & TI  AT 1ST FLOOR & MEZZAZINE OFFICE, ADD STAIRWAY TO MEZZAZINE FLOOR, FULLY  SPRINKLER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50545	11041-20000-06036	10300 W SANTA MONICA BLVD	90025	5	132B157   485	4319009030	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.05855	-118.42191	Plan check for new 600A service and equipment. Load in panels are existing to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50546	19041-10000-04505	1031 S BROADWAY 12th Flr	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	02/20/2024 12:00:00 AM	ADDRESS	34.04041	-118.2583	FULL PLAN CHECK FOR POWER AND ENERGY FOR A HIGHRISE OFFICE. SCOPE OF WORK INCLUDES NEW 600AMP SERVICE,208/120 3PH, CIRCUITS, EQUIPMENT AND LIGHTING. TOTAL AFFECTED AREA 16050 SQFT.  BLD# 19016-10000-03302	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50547	19041-10000-31813	5720 S 2ND AVE	90043	8	108B189  1029	5005005901	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	33.99083	-118.31908	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50548	14041-20002-06289	428 N ALTA VISTA BLVD PV 1	90036	5	141B181  1385	5525026022	R2-1	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.07907	-118.3473	EXPEDITE FEES))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50549	18041-10000-35257	1515 W 190TH ST 1st Flr-STE 101	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	Design build. Energy plan check for an office TI. Scope includes new lighting and equipment with a total area of  1,626-SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50550	15041-20000-21011	7543 N BELLAIRE AVE	91605	2	186B161   384	2305031026	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.20789	-118.41006	Plan check for a PV1 roof-mounted PV system. System size is 3.9 kWac and consists of (18) micro-inverters, (18) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50551	16041-20000-20291	1999 S AVENUE OF THE STARS 20th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check Title 24 only in existing space T.I. Morgan Stanley. Total area: 3881 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50552	15041-10000-09376	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	ADDING ACCENT LUMINAIRES IN LOBBY SALON AND MEN'S SHOE SECTIONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50553	17041-20001-02544	8029 W KYLE ST	91040	7	208-5A193 397	2556004039	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.26475	-118.30805	06/12/2017 Plan check for the addition of a 3.8 kWac PV1 PV system onto an existing 4.2 kWac system for a total system size of 8 kWac. System addition consists of (1) inverter, (8) modules, and (1) load center.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50554	14041-10000-07968	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.09918	-118.32644	PLAN CHECK FOR TEMPORARY POWER (manlifts and crane).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50555	10041-20000-25279	310 S MAPLETON DR	90024	5	138B157    18	4359013022	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2010 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	34.07729	-118.4317	PLAN CHECK FOR NEW 600A SERVICE ELECTRICAL SYSTEM TO EXISTING SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50556	14041-10000-33655	14708 W LAKESIDE ST	91342	7	222B149   237	2505008002	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.30732	-118.45303	Installation of a PV1 roof-mounted PV system. System consists of (1) inverter and (12) modules. System size is 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50557	14041-10000-04681	12500 W BRANFORD ST	91352	6	201B165   107	2629001006	(Q)M2-EZ1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM			Corrections Issued	02/21/2014 12:00:00 AM	ADDRESS	34.24638	-118.40551	Addition of new devices to existing methane mitigation system serving a new maintenance building fed from control panel located in existing building on-site.  11 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50558	17041-10000-36391	555 W 5TH ST GE012	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 1414SQ. FT. B#17016-10000-25690	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50559	19041-30000-24305	4050 S FIGUEROA ST	90037	9	115-5A201 220	5019026009	C2-2D-CPIO	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	Apartment			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.01002	-118.2825	PC FOR FA . APARTMENT BUILDING 5 FLOORS. 1 FACP PANEL AND 165 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50560	15041-10000-13676	2049 S CENTURY PARK EAST 29TH FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	ALTERATIONS ON 29TH FLOOR OF AN OFFICE BUILDING- LIGHTING; CKTS; AND NEW PANEL BOARDPLAB CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50561	14041-10000-30990	5555 E VALLEY BLVD	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.07489	-118.16218	Energy plan check for (2) storage rooms inside a  commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50562	12041-10000-14991	1362 S ABBOT KINNEY BLVD	90291	11	108B145  1403	4238004041	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	33.99047	-118.46597	Plan check for energy and emergency lighting. 1600 sqft. single story commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50563	16041-30000-44696	620 S VIRGIL AVE 100	90005	10	135A201   140	5077007029	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.06288	-118.28683	Plan check for power and energy. Project site is an existing commercial building. Project scope is a first time tenant/tenant improvement for a new Target retail store with a Starbucks coffee shop. Total lighting area = 31,447 sq. ft.Note: Building application has been generated under 16016-30000-30481	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50564	16041-20000-20557	2601 S FIGUEROA ST Bldg 4 on-2 Floor	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Issued	06/15/2016 12:00:00 AM	ADDRESS	34.02804	-118.2763	Plan check Title 24 only in existing space office AAA T.I. Total area: 25,105 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50565	13041-20000-21315	9301 N CORBIN AVE STE 120	91324	12	198B117   116	2761040014	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.24034	-118.56251	Plan check for energy and emergency lighting. Addition of partitions. Building equipped with central battery (inverter). Low-rise office. Suite 120.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50566	19041-10000-02400	9211 N BALCOM AVE	91325	12	198B129   332	2766004011	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.23791	-118.5217	NEW ROOF MOUNTED 11.52 KW PV SYSTEM ON A SINGLE FAMILY HOUSE WITH 32 PV PANELS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50567	09041-10007-24226	13488 W MAXELLA AVE	90292		105B153    77	4212004014	[Q]M1-1, [T][Q]RAS4-1		Palms - Mar Vista - Del Rey	Del Rey			Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM			PC Approved	04/17/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	This revision entails addition of PV feeder to the previously approved plans (( master drawing  )).4-17-13 Mzandi,DELTA 7 REVISIONS (09041-10005-24226) TO PERMITTED SET OF PLANS ( WORK IS UNDER CONSTRUCTION ) CHANGES ARE TO THE LIGHTING SYSTEM AND TO THE LAYOUT  OF THE APARTMENT UNITSALL CHANGES ARE CLOUDED ON THE PLANS(((((((((New 244 apartment building in methane zone.  Variance was filed to separate the the Fire Alarm plans and approval.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50568	17041-20000-18875	865 S FIGUEROA ST 2nd Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for Title 24 only. Project site is a portion of the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,756 sq. ft.Note: Building permit has been issued under 17016-10000-10157	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50569	14041-10000-08545	3442 N LINDA VISTA TER	90032	14	142-5A235  86	5219012013	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.0859	-118.17115	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50570	11041-10000-26872	2301 N KENILWORTH AVE	90039	4	148-5A205 272	5432020021	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2011 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	03/08/2012 12:00:00 AM	ADDRESS	34.10093	-118.26742	Plan check roof mounted 3.05KW Enphase M215 microinverter photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50571	13041-20000-06900	18810 W KIRKCOLM LANE PV-1	91326	12	216B121   101	2820014018	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.29203	-118.54316	PV-1. Plan check for PV. 12.0kW roof mount. One 7kW inverter and one 2.5 kW inverter. Please include 225A service upgrade for permit fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50572	17041-20000-28522	20016 W BLYTHE ST	91306	3	189B113  1442	2106003135	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.21466	-118.56922	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (20) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50573	18041-10000-05061	334 S AVENUE 17	90031	1	136-5A219 133	5447029013	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.06827	-118.22162	Energy plan check for an existing warehouse. Scope includes new lighting and equipment. Total area is (9000) SQ Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50574	10041-10000-00052	1480 N VINE ST unit-B	90028	13	147A189   227	5546025027	(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			01/04/2010 12:00:00 AM			PC Info Complete	02/25/2010 12:00:00 AM	ADDRESS	34.09747	-118.32646	First time tenant for commercial building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50575	19041-20000-40265	1650 S SAWTELLE BLVD	90025	11	129B149   519	4261008024	(Q)RAS4-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Apartment			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	08/11/2021 12:00:00 AM	ADDRESS	34.04594	-118.44777	Plan check for new fire alarm system for 5 story  48 units building, new fire alarm devices: 151 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50576	15041-10000-01636	415 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.77391	-118.27885	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 8308 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50577	12041-10000-28240	3501 S WATT WAY	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.02243	-118.28658	REGULAR PLAN CHECK. USC HERITAGE HALL RECAPITALIZATION PROJECT. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50578	16041-20001-25578	2232 N LIVE OAK DR WEST	90068	4	151-5A193  84	5587005025	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.11085	-118.31095	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM.  ADDITION TO EXISITNG PV SYSTEM WITH BATTERY BACKUP.  JLM ENERGIZR 100 SMART INVERTER.  EXISTING SYSTEM SIZE: 8.8 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50579	15041-20000-30094	1930 W 94TH ST	90047	8	094-5A193 353	6057012024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	33.95112	-118.31258	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (25) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50580	15041-10001-31686	2218 S COTNER AVE	90064	5	126B153   968	4322024004	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.03874	-118.43869	Supplemental PC and Permit to 15041-10000-31686. PC for T-24, adding branch ckt. total area: 4461 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50581	15041-10000-08918	454 E COMMERCIAL ST PV	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.05313	-118.23621	PV2, INSTALL 336 KW AC ROOF-MOUNTED SOLAR ARAY ON ROOF OF THE PARKING STRUCTURE, PARKING LOT, AND M&O BUILDINGS. TIE WITH MAIN 3000 A SERVICE PANEL. (1399) MODULES AND 13 CENTRAL INVERTERS. ALL PV NET METERS 454 E COMMERCIAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50582	16041-10000-41122	10561 W BUTTERFIELD ROAD	90064	5	126B161   473	4318014029	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.03874	-118.41645	PV1 5.12 KW AC roof-mounted system with (16) AC modules interconnecting through the load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50583	18041-10000-24200	10801 W CHANDLER BLVD	91601	2	174B173  1312	2416015900	PF-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM			Reviewed by Supervisor	07/31/2018 12:00:00 AM	ADDRESS	34.16881	-118.36593	PV2. NEW SOLAR SYSTEM ON A COMMERCIAL BUILDING AND ON A CARPORT. TOTAL SYSTEM SIZE IS KWac.(222)MODULES-FRONIUS 12.0-3(5)INVERTER-FRONIUS 12.0-3(2)INVERTER-FRONIUS 15.0-3 (7)COMBINER BOXES(1)200A PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50584	14041-10000-13222	11622 W OXNARD ST	91601	2	177B169  1101	2338008024	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	PIN	34.17920081	-118.38519232	PV1, INSTALL  2.75  KW DC ROOF-MOUNTED SOLAR ARRAY ON A 4-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50585	14041-20001-24887	7014 S HOOVER ST UNIT 5	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 5.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50586	10041-20000-06743	12265 W VENTURA BLVD Unit 209	91604	2	162B165   111	2367017016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	04/21/2010 12:00:00 AM	ADDRESS	34.14328	-118.40035	Installing light in office areas of a building. This plan check is title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50587	14041-10000-33470	1875 CENTURY PARK EAST 15th FL	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	PIN	34.06139196	-118.41527843	Tenant improvements in office space plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50588	15041-10000-35942	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	33.94955	-118.38342	NEW FIRE ALARM PANEL TO A WAREHOUSE BUILDING. (135) DEICES, 1 FIRE ALARM PANEL, 1, ANNUNCIATOR PANEL, 3 POWER SUPPLIES. AND AN AUDIO AMPLIFIER PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50589	14041-10000-09754	12685 W PIERCE ST	91331	7	210B161   606	2536006010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Expired	05/20/2016 12:00:00 AM	ADDRESS	34.27004	-118.40966	PV1, Install 4.75 kw DC roof-mounted solar array on a one-story home, interconnect with main service panel.(1) Transformerless Inverter: SOLAREDGE SE3800A-US-ZB-U(19) CANADIAN SOLAR CS6P-250X	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50590	16041-10000-36292	777 S FIGUEROA ST SUITE 3650	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.04828	-118.26116	TI IN SUITE 3650. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50591	17041-10000-36375	1071 S GLENDON AVE	90024	5	132B153   117	4363020002	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.0612	-118.4445	INTERIOR TI INSIDE RESTAURANT-NEW LUMINIRES AND CONTROLSPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50592	10041-10000-24389	2501 W SUNSET BLVD Suite A	90026	13	141A205   271	5402015026	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	05/24/2011 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	34.07974	-118.26907	T-24 lighting plan check for combination restaurant bakery.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50593	10041-20000-14202	2801 N CLEARWATER ST	90039	13	150A211    28	5437028009	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1873.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Issued	09/01/2010 12:00:00 AM	ADDRESS	34.10727	-118.25344	service upgrade 600 amps	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50594	14041-10000-25722	10700 W SANTA MONICA BLVD	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM			PC Info Complete	09/18/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	PLANCHECK FOR T24 ENERGY. CHANGE OF OCCUPANCY FROM MEDICAL TO NON-MEDICAL OFFICES. NO PATIENT CARE AREA PER APPLICANT. 5146 SQFT, EMERGENCY LIGHTING.  3RD FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50595	10041-10000-22566	732 E 10TH ST #108 &109	90021	9	124-5A211 195	5132011030	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	12/22/2010 12:00:00 AM	ADDRESS	34.03504	-118.25099	First tenant in retail space formed by the combining two tenant spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50596	18041-10004-16557	4121 W SANTA MONICA BLVD	90029	13	145-5A201 370	5429002035	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM			PC Approved	09/04/2019 12:00:00 AM	ADDRESS	34.09205	-118.28241	DELTA 4 CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE MODIFICATION OF RESIDENTIAL AND HOUSE PANEL FEEDERS TO UPDATE LENGTH AND SIZE TO MATCH INSTALLED CONDITIONS. HOUSE PANEL RELOCATED TO SECOND FLOOR. VOLTAGE DROP AND FAULT CURRENT CALCULATIONS ARE UPDATED ACCORDINGLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50597	17041-10000-19444	1311 W CARSON ST	90501	15	051B197   138	7349030021	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	33.83171	-118.30005	REPLACE HID FIXTURES FOR LED TYPE(14 FIXTURES). TOTAL AFFECTED AREA 26000 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50598	15041-20001-11170	21031 W VENTURA BLVD 501	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	PIN	34.16717222	-118.59179488	Plan check for Title 24 for office T.I. Total area: 991 sq ft. Tenant Improvement of Office Suite 501	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50599	15041-20000-07307	1048 S LA BREA AVE	90019	10	132B181   763	5084013019	C2-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.05644	-118.34498	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 883 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50600	18041-10000-15942	11641 N CORBIN AVE	91326	12	213B113   277	2701057900	PF-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.28132	-118.5698	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50601	18041-10000-42741	3628 N VERDUGO VISTA TER	90065	1	154-5A219  56	5472013002	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.11928	-118.22334	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM AND ENERGY STORAGE SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600-USS), 23 MODULES/P30 OPTIMIZERS, AND LE CHEM BATTERY(9.8KVA)FEES $0.00 DUE TO CALIFNORNIA SENATE BILL 1222 AND AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50602	17041-10001-43627	1108 W SANTA CRUZ ST	90731	15	018B193   599	7452005036	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.02	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2017 12:00:00 AM			PC Approved	12/22/2017 12:00:00 AM	ADDRESS	33.74476	-118.30084	PC  FOR REVISIONS TO APPROVED SET. SCOPE OF CHANGES INCLUDES NEW ROOF LAYOUT FOR 8 MODULES  AND RELOCATION OF INVERTER. THIS IS PLAN CHECK ONLY. PERMIT PAID UNDER MASTER. PC for 5kW rooftop PV for SFD. Installing 25 new modules with optimizer and one central 5kW inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50603	19041-10000-14308	4130 N CAHUENGA BLVD	91602	4	165B177  1002	2424040008	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.14515	-118.36125	T-24 PLAN CHECK FOR A TI IN A PARKING STRUCTURE. SCOPE INCLUDES NEW CIRCUITS, LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 34527 SFB# 18016-10000-40917	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50604	15041-10001-07967	10431 W SANTA MONICA BLVD	90024	5	132B157   661	4327006008	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	PIN	34.05716086	-118.42526721	PLAN CHECK FOR TITLE 24 COMPLIANCE- CHANGES TO THE LIGHTING SYSTEM APPROVED ON ORIGINAL PERMIT{{{{{{{{{{Energy plan check for a change of use from retail store to a bank; .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50605	15041-20000-18663	6316 N TOPANGA CANYON BLVD SPACE 1130	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. SUNGLASS HUT AT VILLAGE AT TOPANGA.  1025 SQFT. BUILDING B - SPACE # 1130.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50606	17041-20000-21301	10905 W CHALON ROAD	90077	5	141B149    43	4369028002	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM			PC Approved	07/16/2019 12:00:00 AM	ADDRESS	34.08497	-118.45543	Plan check for power only. Project site is a new single-family home. Work includes a new 1,200-amp service and back-up generator.Note: Building permit has been issued under 14010-20000-03942. Electrical permit fees have been paid under the combination building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50607	16041-20000-36998	2616 N HYPERION AVE	90027	4	150A205   138	5432001012	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.10594	-118.27246	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. MAD HATTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50608	16041-10000-39196	2636 N LAKE HOLLYWOOD DR	90068	4	159B185   148	5577038034	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.12921	-118.32871	PV,  INSTALL NE 6.7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MICRO INVERTER: SUNPOWER SPR-X21-335-BLK-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50609	13041-20000-29986	6320 N KRAFT AVE	91606	2	177B169    51	2335018015	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.18558	-118.38	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.8 KW. 30 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50610	12041-20000-02374	300 S GRAND AVE 33RD FL	90071	9	132A211    50	5149010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	03/12/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.05283	-118.25116	Energy plan check floor # 33  <<<< fees for permit are under INSPECTION, new lighting, receptacles, loads for an existing high-rise office building on the 33rd floor.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50611	15041-10000-44020	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	PC FOR POWER , AMA BUILDING. TI FOR 22ND FLOOR. ADDING 6 NEW  PANELS AND 3 NEW 75 KVA TRANSFORMERS. TOTAL AREA  16046 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50612	16041-20000-16700	14837 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.17767	-118.4555	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50613	13041-10001-35542	2065 N SYCAMORE AVE	90068	4	150B181   298	5549024043	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.10779	-118.34126	Express RSES plan check per applicant request. {{PV1, Install 5.75 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (23) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50614	11041-10000-09573	20000 S WESTERN AVE	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	33.85008	-118.30908	NEW CORE AND SHELL FOR A BRAND NEW SINGLE STORY COMERCIAL BUILDING.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50615	19041-10000-19570	9741-9803 N INDEPENDENCE AVE	91311	12	201B105   158	2746003018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			Reviewed by Supervisor	06/20/2019 12:00:00 AM	ADDRESS	34.247	-118.59099	(Assign to Edwin or John per Mr. Nabil request)PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 1572 MODULES (Q-PEAK 390), 786 OPTIMIZERS (P850 ), 4 INVERTERS ( SE 99.9K), AND 1 INVERTERS ( SE 66.6K). SYSTEM SIZE IS 466.2KWac AND 613.08KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50616	13041-10000-20344	16000 W VENTURA BLVD 101	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.15584	-118.48164	BANK INTERIOR REMODELING IN HIGH-RISE BUILDING; EMERGENCY CIRCUITS ARE TO BE CONNECTED VIA EXISTING GENERATOR IN BUILDING. WORK IS DONE FOR TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50617	15041-10002-14961	5501-5505 W PICO BLVD	90019	10	129B177   824	5085030001	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	34.04914	-118.35756	Change to approved set by modifying the lighting plan and adding receptacles and equipment to approved set. Note. all changes are under delta-2 only.(((CHANGE IN NUMBER OF FIXTURES. REDUCE NUMBER OF INSTALLED. ALSO CHANGED EMERGENCY LIGHTING TO BUG EYE TYPE. PC FOR CHANGES CLOUDED DELTA  1 ONLY. NO OTHER CHANGES NOTES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50618	17041-20000-09615	9351 N LAUREL CANYON BLVD	91331	6	198B161   272	2629027014	(Q)MR1-1, (Q)P-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Closed	10/08/2021 12:00:00 AM	ADDRESS	34.23901	-118.41146	Plan check for power only. Project site is an existing commercial building (H-3 occupancy), chemical storage and no hazardous areas. Project scope is the installation of a generator and new load on existing distribution equipment.Note: Building application has been generated under 17016-20000-06967	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50619	13041-20000-20000	19723 W INGOMAR ST	91306	3	189B117   733	2106029023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.21249	-118.56315	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.2 KW USING 2 CENTRAL, TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 34 MODULES. PERMIT SHALL INCLUDE MAIN SERVICE AND PANEL UPGRADE TO 200 AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50620	10041-10002-20763	3233 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035012	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.02889	-118.37311	Modifications to previously approved set of plans.  Includes T24, emergency lighting , and new circuits.  Copy of the original approved set submitted with new plans. DELTA 3 & 4 CHANGES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50621	17041-30000-06382	905 N WILCOX AVE	90038	13	144B185  1161	5533022011	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.08735	-118.33123	Plan check for a fire alarm system for a 4-story, 17-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (76) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50622	19041-10001-41751	11518 W KILLION ST	91601	2	174B169  1012	2350007018	[Q]RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM			PC Approved	10/15/2019 12:00:00 AM	ADDRESS	34.17117	-118.38283	CHANGES TO AN APPROVED SET. INVERTER TYPE CHANGED FROM SE7600H-US TO SE7600A-US.PERMIT IS UNDER ORIGINAL.ORIGINAL WORK DESCRIPTION: PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 7.6KWac/7.705KWdc. SCOPE OF WORK IS 23 MODULES (LG335N1C-A5) WITH OPTIMZERS (SE P370), LEADING TO A CENTRAL INVERTER (SE7600H-US), NO MAIN PANEL UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50623	10041-10000-20550	637 S FAIRFAX AVE #101 & 102	90048	13	135B177   590	5510027***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM	11/01/2010 12:00:00 AM		Permit Finaled	12/27/2010 12:00:00 AM	PIN	34.06385859	-118.36170104	TI IN AN EXISTING COMMERCIAL SPACE IN UNIT #'S 101& 102 ON THE 1ST FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50624	17041-30000-46209	1224 S SOTO ST	90023	14	121-5A221 127	5170018019	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.10	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.02732	-118.21934	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,351 sq. ft.Note: Building application has been generated under 17016-20000-33598	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50625	16041-10001-26325	1603 E 53RD ST	90011	9	108B213   128	5105001019	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	33.995	-118.2453	Permit fees are $0 due to senate bill 1222. 08/04/16Changes to an approved set of plans. Changes include adding a new 100A subpanel on the single line diagram, changing conductors, and replacing the PV back-fed breaker. (((((PV1 roof mounted solar system installation to a single family home. Installing (12) microinverters M250-60-2LL rated at 250 watts each for a total system size of 3.0 kw.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50626	17041-10000-07544	11100 S CENTRAL AVE	90059	15	088-5A211 534	6070006010	PF-1, [Q]CM-1	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.93513	-118.254	PC FOR ENERGY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL ARAE 86550 SQ FT. /INDOOR+OUTDOOR/	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50627	18041-20000-07124	9541 N OAKRIDGE PL	91311	12	201B097   153	2724011006	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.24393	-118.62088	addition of (2) tesla power walls to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50628	16041-20000-16740	9628 N HILLHAVEN AVE	91042	7	201A199   282	2563036002	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.24447	-118.29081	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.2 KW.  MICROINVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50629	17041-10000-46678	1060 N VINE ST	90038	13	144B189   743	5534022032	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.09019	-118.32643	Plan check for Title 24 only in existing space Massage Parlor. Total area: 1,139 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50630	17041-20001-29062	15105 W MISSION HILLS ROAD	91345	7	213B145    24	2664022013	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM			PC Approved	07/13/2018 12:00:00 AM	ADDRESS	34.28165	-118.4621	07-13-2018 Changes to an approved set of plan. Changes include replace 2x4 Metalux Lighting fixture to 2x2 Metalus lighting fixture in Dining room,  Activites, Kitchenette, Laundry. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50631	14041-10000-35876	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.27455	-118.56289	Exterior lighting for tram stop serving existing church complex.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50632	14041-10000-14879	12650 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	33.9774	-118.4142	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50633	17041-10000-44330	2625 S ROBERTSON BLVD	90034	5	126B169  1420	4301006002	C4-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Info Complete	12/08/2017 12:00:00 AM	ADDRESS	34.03782	-118.38868	PC FOR T.I. OF EXISING RESTAURANT FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW EQUIPMENT CIRCUITS AND LIGHTING. TOTAL AFFECTED AREA 615 SQ.FTB# 17016-10000-31597	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50634	11041-10000-00306	1521 W PICO BLVD # 111	90015	1	127-5A203 102	5137032023	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.04432	-118.27583	TENANT IMPROVEMENT IN RETAIL SPACE-NEW PANEL/CKTS/LIGHTINGPLAN CHK IS FOR TITLE 24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50635	14041-10000-01393	1602 N CLEAR VIEW DR	90210	5	147B153   104	4356006021	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Expired	04/16/2020 12:00:00 AM	ADDRESS	34.1009	-118.43407	Plan check for new 600A service and switchboard upgrade for existing dwelling. All panels, circuits, and equipment are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50636	14041-20000-21763	8156 N KELVIN AVE	91306	3	192B109   838	2108008022	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.2188	-118.58542	PV1Central/String Inverter standard plan.Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 3.6kW(1) PowerOne PVI-3.6-OUTD-US-Z-A transformerless inverter(17) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50637	18041-10000-20125	1301 W 7TH ST	90017	1	130-5A205 108	5143013022	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Closed	12/31/2019 12:00:00 AM	ADDRESS	34.05249	-118.26766	NEW FIRE ALARM SYSTEM IN A 6 STORY MIXED USE BUILDING.INSTALL (1) FACP, (3) RPS, (<<Building Permit #16010-10000-05931>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50638	18041-10000-15028	1035 N SWARTHMORE AVE	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	NEW CORE AND SHELL FIRE WARNING SYSTEM FOR BUILDING 1 AT THE PACIFIC PALISADES VILLAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50639	19041-10000-48939	380 WORLD WAY BLDG B	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	POWER PLAN CHECK PER APPLICANT REQUEST FOR LAX CONTROL ROOM ADDITIONAL CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50640	17041-10000-16614	15760 W VENTURA BLVD #950	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	PC FOR TI IN OFFICE SPACE. TITLE-24 ENERGY ONLY. TOTAL AFFECTED AREA 1127 SQ.FTINSTALLING NEW  LIGHTS AND RECEPTACLES.BL# 17016-10000-12737	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50641	13041-10000-18211	6600 N TOPANGA CANYON BLVD #1002	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	07/29/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	permit to be pulled at EPC counter only. PC for energy only. TI TO EXISTING RADIOSHACK. INSPECTOR TO VERIFY IF MALL HAS GENERATOR. SPACE #1002. less than 400A  with emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50642	16041-20000-39650	17301 W VENTURA BLVD	91316	5	171B133   691	2257016001	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.16106	-118.51005	Plan check for energy only. TI to retail space (Three Dog Bakery). New lighting (incl. emergency). 1,211sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50643	18041-20000-02526	17000 W RINALDI ST	91344	12	213B133   720	2697019024	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	04/20/2021 12:00:00 AM		Permit Finaled	06/30/2022 12:00:00 AM	ADDRESS	34.2791	-118.50253	PLAN CHECK FOR POWER AND ENERGY FOR NEW MARKET FOR (E) GAS STATION  . DISTRIBUTION BOARD = 600A, TOTAL AFFECTRED AREA = 1954 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50644	18041-20000-32819	7230 W FOOTHILL BLVD D104	91042	7	202-5A199 503	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Closed	11/16/2022 12:00:00 AM	ADDRESS	34.24846	-118.28965	first time tenant. plan check for power and energy.partial permit fees paid under express permit 18041-20000-15874	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50645	15041-10000-06920	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.06326	-118.20213	New 5 story Medical Building. Includes Power & Energy and OSHPD  3 PLAN REVIEW.Core & Shell was approved under 14041-10000-29044	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50646	19041-10003-00182	3475 S STONER AVE	90066	11	117B153  1102	4249015003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.01339	-118.43259	SUPPLEMENTAL PLANS CHECK FOR ( DELTA 3 ) CHANGES TO APPROVED SET - CHANGES INCLUDE CHANGING ON MODULE MODEL FROM SC325 TO SC330.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50647	13041-20000-20168	9921 N WHEATLAND AVE	91040	7	204B177   200	2542013011	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.25177	-118.36074	pv1 single family dweling. total system size 2.45 kw using 10 modules. central inverter transformerless. nonstandard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50648	19041-20000-38493	1806 N GRAMERCY PL	90028	13	150A193   560	5544003034	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	10/29/2020 12:00:00 AM	ADDRESS	34.10364	-118.31211	Plan check for new fire alarm system for 4 story 10 units multi-family. Total fire alarm device: 67  and 1FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50649	19041-10000-52552	19201 W CELTIC ST	91326	12	210B121   557	2718010034	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Issued	12/19/2019 12:00:00 AM	ADDRESS	34.26976	-118.55094	NEW RESIDENTIAL ROOFTOP PV1 SOLAR SYSTEM WITH BATTERY BACKUP. SYSTEM CONSIST OF 24 MODULES (Q-PEAK 315), 1 CENTRAL INVERTER ( SOLIVIA 7.6 TK) AND 2 TESLA POWER WALL. SYSTEM SIZE IS 7.56KEDC AND 7.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50650	18041-10001-11087	1011 S SERRANO AVE	90006	10	129B193   356	5080014012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Public Safety Only			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.0522	-118.3065	Suppl App for DELTA changes to approved plans for the additional 62 devices to a Fire warning system for 5-stories 104 units apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50651	18041-10000-05121	817 N VINE ST Bldg A	90038	13	141B185   173	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.0858	-118.32679	New Fire Alarm system on a  Renovation of existing office building (Bldg A). (3) FA panels, (75) FA devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50652	18041-20000-17677	11601 W WILSHIRE BLVD STE 470	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing space T.I. office space. Total area: 3934 sq ft.B#18016-10000-13117	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50653	10041-20000-20846	18700 W VENTURA BLVD	91356	11	150B133    42	4491005012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM			PC Approved	10/20/2010 12:00:00 AM	ADDRESS	34.17045	-118.54081	install feeders to panels and panel boards future load need complete plan check existing permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50654	19041-10000-15910	10803 W SATICOY ST	91352	2	186B177   156	2409016043	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.20859	-118.3662	New 6kW AC rooftop solar on (E) SFD, install (1) 6kW inverter, (26)modules, (26) P320. System connect to 200A MSP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50655	16041-10000-21471	6871 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	33.93198	-118.41079	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 1200AMP ( 277/480V 3PHASE 4 WIRE) SERVICE.  NEW SERVICE IS FOR A MODULAR BUILDING/ IMPERIAL SUITES. SCOPE INCLUDES NEW CIRCUITS, 2 NEW PANELS, 2 NEW DISTRIBUTION BOARDS(1200 AND 1600 AMP).TOTAL AFFECTED AREA IS 20100 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50656	14041-10002-29516	6614 W HOLLYWOOD BLVD	90028	13	148-5A185 130	5547015013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM			PC Approved	11/05/2015 12:00:00 AM	ADDRESS	34.10141	-118.33371	Change to approved set by modifying the lighting plan and reducing the installation wattage; All changes are under delta-7 only.(((Change of use to joint living and work quarters. Energy plan check for 1st floor recording studio ONLY)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50657	14041-20001-02291	9019 N HASKELL AVE	91343	12	195B141    97	2672006044	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.23424	-118.47653	(((EXPEDITE FEES))PV1 SINGEL FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50658	15041-10000-17978	2753 W WAVERLY DR BLDG 9	90039	4	151-5A207 233	5438025***	RD2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.10855	-118.26334	NEW DEVELOPMENT FOR MULTI BUILDING TOWNHOUSES 600 AMP SERVICE.  THIS IS BUILDING 4 OF 5.  PLAN CHECK FOR POWER AND ENERGY.  EACH BUILDING HAS ITS OWN SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50659	13041-10000-25394	12057 W WILSHIRE BLVD	90049	11	126B145    66	4265016027	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	PIN	34.04495689	-118.46700701	Interior remodel for Ralph's supermarket.  T24 plan check only for changes to interior lighting (new track lighting).   All interior emergency egress lighting is existing to remain.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50660	17041-20001-41616	12700 W VAN NUYS BLVD bldg 19	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.27528	-118.4092	expeditepv2install roof mounted pv system sized 3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50661	19041-30000-05142	355 S GRAND AVE 14th Floor	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.05191	-118.2525	Plan check for Title 24 only. Project site is the 14th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,356 sq. ft.Note: Building permit has been issued under 19016-10000-00252	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50662	15041-10000-02341	8161 W BEVERLY BLVD	90048	5	138B173   375	5514008045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.07624	-118.36735	Plan check for methane gas mitigation detecting system with (1) communication panel, (1) control panel, & (21) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50663	16041-10000-31242	12463 W VICTORY BLVD	91606	2	180B165 704	2333033031	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	ADDRESS	34.18684	-118.40498	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING 7 ELEVEN CONVIENCE STORE. SCOPE INCLUDES REPLACING/ADDING LIGHTING FIXTURES WITH LEDS. TOTAL AFFECTED AREA IS 1756 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50664	17041-20000-16879	5142 S BRYNHURST AVE	90043	8	108B185    76	5013007018	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.99546	-118.33316	Plan check for a PV1 roof-mounted PV system. System size is 3.5 kWac and consists of (14) micro-inverters and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50665	06041-10010-09913	1633 N LA BREA AVE	90046	4	147B181   287	5548008010	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Apartment			08/15/2011 12:00:00 AM	08/26/2011 12:00:00 AM		Permit Closed	12/09/2011 12:00:00 AM	ADDRESS	34.10058	-118.34527	DELTA 15 THRU DELTA 18  REVISIONS TO APPROVED SET OF PLANS- CHANGES TO INTERIOR  AND APARTMENT LIGHTING SYSTEMS; CHANGE RECREATION ROOM TO FITNESS ROOM  ; NEW CIRCUITS; REVISED LOAD CALCULATIONS;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50666	17041-10000-24158	21621 W NORDHOFF ST	91311	12	198B105   180	2746011004	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.23563	-118.60152	Remove HID fixtures and replace with new LED fixtures - T 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50667	11041-10000-12950	17301 W PACIFIC COAST HWY	90272	11	126B117   670	4416003027	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			PC Approved	06/28/2011 12:00:00 AM	ADDRESS	34.03879	-118.55602	T.I.  Existing gas station.  Modification to interior lighting.  Per inspector's request, plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50668	18041-10001-17514	1942 W 1ST ST	90732	15	018B189   267	7559012023	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	09/25/2023 12:00:00 AM	ADDRESS	33.74306	-118.31845	SUPPLAMENTAL FOR THE ENERGY STORAGE SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50669	15041-10004-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR CHANGES TO APPROVED UNDER DELTA 11 AND 12.SCOPE INCLUDES : DELTA 11 CHANGES ARE MAINLY FOR MACY'S SPACE AND INCLUDE LIGHTING, SINGAGE, TRANSFORMER SIZE AND SOME CIRCUITS. DELTA 12 CHANGES TO REFLECT CHANGES ON FIELD MAINLY DUE TO CONSCIERGE ON 6TH FLOOR AND INCUDE NOTATIONS, LIGHTS REVISIONS, PANEL UPDATES ETC. *This is plan check only, permit is covered under master permit # 15041-10000-43822	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50670	16041-30000-37176	11060 W RANDALL ST	91352	6	198B173   103	2408003041	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.23647	-118.37205	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50671	19041-10000-00453	1415 S LA CIENEGA BLVD 1-6	90035	5	129B173   220	4303035035	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.05271	-118.37633	T-24 ENERGY ONLY PLAN CHECK FOR TI FROM DRYCLEANING TO MASSAGE PLACE. TOTAL AFFECTED AREA IS 858 SQ.FTB#18016-10000-39192	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50672	17041-10001-23505	15700 W VENTURA BLVD	91436	5	168B141   677	2283006049	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM			PC Approved	02/04/2019 12:00:00 AM	ADDRESS	34.15494	-118.47519	Change to an approved set of plan. Changes include adding 4000-SQ FT, distribution panel is changed from new to existing. Original plan checker is Mehdi Zandi,  applicant prefer Isaac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50673	16041-10001-45771	380 WORLD WAY MSC-PAX	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	02/10/2020 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Delta 2 and 3 changes to an approved set. Changes include circuit modification and load update. Scope includes 4 upgraded panels. Original Plan check: (Full Plan check. Adding new lighitng, power, and emergeny power to LAX MSC PAX tunnel (Scope includes anything under 'TPX' labels on single line). Total area: 54000. b#16014-10000-02498)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50674	18041-20000-30069	15932 W GAULT ST	91406	6	183B141   259	2224008038	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Issued	08/09/2018 12:00:00 AM	ADDRESS	34.19924	-118.48063	Plan check for PV roof mounted system, system size: 14.52KW AC CEC, 13.2KW DC, with 44 modules and 44 microinverters(Total wattage:10.5kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50675	15041-10000-06218	8839 N SNOWDEN AVE	91331	6	195B153   691	2640017007	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.2305	-118.43539	PV1.  Install 2.943 kW roof-mounted, utility-interactive PV system including (1) 3kw SB3000TL inverter, and (9) Sunpower SPR327 modules.  PV standard plan. Plan check per customer request	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50676	19041-10000-17672	10585 W SANTA MONICA BLVD 1st-3rd Flr	90025	5	132B157  1074	4326033042	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.05433	-118.42915	Full PC for a an office T.I loacted on the 1st, 2nd and 3rd floor of a commercial buidling. Scope includes new lighting and equipment with a total lighting area of 68,710-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50677	16041-20000-20180	7435 N VALJEAN AVE	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.20582	-118.48615	PLANCHECK FOR POWER AND ENERGY PER APPLICANTS REQUEST. T.I TO (E) CORE AND SHELL PROJECT UNDER CONSTRUCTION. VAN NUYS OFFICE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50678	17041-20001-26122	1251 S EDRIS DR	90035	5	132A167   372	4330024041	RD1.5-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			08/01/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.05575	-118.39818	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.65 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50679	14041-10000-02021	777 S CENTRAL AVE	90021	14	124-5A213 395	5146007005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Public Safety Only			01/23/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Closed	05/21/2014 12:00:00 AM	ADDRESS	34.03464	-118.24302	installation of sprinkler monitoring system in commercial buildingPLAN CHK IS REQUIRED BECAUSE OF FIRE ALARM PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50680	15041-20000-43937	816 N FAIRFAX AVE	90046	5	141B177   176	5527002034	C2-1VL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.08591	-118.36121	Plan check fornew fire alarm system for Fairfax Studio. Total devices: 13	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50681	10041-10000-12781	500 W WORLD WAY MCP-05	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	SABS baggage handling system, MCP-05. This applicaation separates MCP-05 from the entire project on PCIS 09041-10001-24166( Upgrade existing and add new conveyor systems in terminal 5 at L.A.X. )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50682	17041-10000-18811	8025 N HASKELL AVE #102	91406	6	189B141    42	2206004011	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.21671	-118.47512	PC for energy only, Indoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 5,500 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50683	12041-20000-09246	1100 S GLENDON AVE	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.06074	-118.44418	Plan check for energy. Small office. 765 conditioned sqft. High-rise. Emergency lighting is not within scope of work and is located in hallway.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50684	11041-10000-10645	20701 W PLUMMER ST	91311	12	201B109   305	2748003071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM	05/25/2011 12:00:00 AM		Permit Finaled	08/25/2011 12:00:00 AM	ADDRESS	34.24287	-118.58449	Ti in a commercial Bldg. Epc is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50685	18041-20000-37794	7043 N JORDAN AVE	91303	3	183B105   495	2138003019	(Q)R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.19858	-118.60298	Plan check for new fire alarm system for apartment building. Total fire alarm devices: 105 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50686	13041-10000-35522	1891 N ACADEMY DR TRAINING-FACILITY	90026	1	141B213    20	5415005902	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.08305	-118.2417	INSTALLATION OF NEW FIRE ALARM SYSTEM IN 2-STORY BUILDING. BUILDING OCCUPANCY B,E; FULLY-SPRINKLERED. 1 FIRE ALARM CONTROL PANEL, 78 DEVICES, (1) REMOTE POWER SUPPLYNOTE: ELECTRICAL PLANS APPROVED UNDER SEPARATE PC# 13041-10000-30473	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50687	18041-10000-27062	621-623 W 97TH ST	90044	8	093A201   239	6054027021	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	33.94836	-118.28546	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.64 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50688	19041-10000-34635	4371 S GLENCOE AVE	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.9857	-118.43834	PC for T24 only, scope of work is changing lights in a wax room to LED. Total affected area is 480 sqft. Note controls and circuits are exisiting to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50689	14041-10000-35908	1767 W BLAKE AVE	90031	13	147A213   170	5442009002	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.09633	-118.24227	Energy plan check by removing HID lighting and install LED fixture for 2 warehouses.warehouse-1 has (12) new LED lighting and will be inspected under T-24 inspection; Warehouse-2 only have (6) new LED and will be inspected under express permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50690	18041-20000-32614	11611 W MOORPARK ST	91602	2	165B169   260	2365002013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Apartment			08/27/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.15053	-118.38594	new fire alarm system 51 devices plus FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50691	17041-10001-45062	301 S MUIRFIELD ROAD	90020	4	135B185   102	5505009012	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	34.0686	-118.32894	Supplemental for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50692	13041-10000-34665	1248 N MARIPOSA AVE	90029	13	144B197    69	5540004004	RD2-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.09466	-118.29931	PV1. ROOFMOUNTED SOLAR SYSTEM, MICROINVERTER NON STD PLAN. 3 KW DC SYSTEM SIZE.UNGROUDED.( 12) 250W MODULES(12) ENPHASE 215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50693	17041-20001-21342	1055 W 7TH ST	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.0507	-118.26334	06-29-18 changes to an approved set, Changes include PV system reduction in size from 240kWac to 180kWac and from 776 modules to 608 modules. Plan check only. Building permit  # 17014-20000-03025  OPEN SOLAR PARKING CANOPY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50694	19041-20000-12635	9230 W NIGHTINGALE DR	90069	4	150B169  1353	5561007027	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	ADDRESS	34.10377	-118.38927	new sfd 800 amp service.  plan check for power only.  building application under 18010-30000-02336electrical fees under building combo permit, this is plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50695	16041-30000-35001	5757 W CENTURY BLVD 415-425	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	33.9457	-118.38274	Title 24 plan check.  T.I. to combine existing 2 suites(# 415 & # 425) in one.  New lighting, receptacles, and one new subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50696	16041-20003-26751	10534 W SANTA MONICA BLVD 1-9	90025	5	132B157  1078	4317004016	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.05456	-118.42769	09/07/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta E. There have been revisions to the lighting floor plan. Changes have been reflected onto the Title 24 Compliance Certs. Emergency lighting is now being powered with inverters.7.16.2018 - Plan check for change to approved set.  Reduction of elevator HP rating from 40 HP to 15 HP.  ======10.20.2017 - Plan check for changes to approved set. Adding 30HP fire pump and garage supply fan (GSF-1). Adding fire dampers. Service equipment boards MS1 and MS3 are fed through bussing instead of feeders. Changes clouded delta C.======plancheck for power and energy.  new 37 unit apartment 5 story over 3 subterranean parking. [ FEES ARE BASED ON PRECUT CHECK, PLANCHECKER TO RECALCULATE].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50697	13041-10001-19837	14800 S FIGUEROA ST	90248	15	075B201   141	6129001046	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	02/21/2014 12:00:00 AM	ADDRESS	33.89809	-118.28288	PLAN CHECK POWER TO FURNACE. TITANIUM TEMPER FURNACE; HAZARDOUS.  permit pulled under original (plan check per inspector request). charge the difference for this plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50698	19041-30000-14953	2049 S CENTURY PARK EAST 4th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site are common area restrooms on the 4th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50699	18041-20000-15775	126 N LA BREA AVE	90036	5	138B181   706	5513003012	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.07449	-118.34383	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50700	16041-20000-40827	24410 W CALVERT ST	91367	3	177B089   298	2032012009	A1-1, RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.1827	-118.65661	remove existing hid fixtures and replace with led.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50701	14041-20000-22943	6241 N PAT AVE	91307	12	177B085    37	2032008016	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.18505	-118.65887	PV1.  Install 7.905 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50702	17041-10000-18003	3201 S HOOVER ST STE # 1815	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.02548	-118.28442	PC FOR FIRST TIME TI TO RETAIL SPACE. PC FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50703	16041-10000-10073	5971 S MAIN ST	90003	9	105B201   542	6005015031	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	33.98545	-118.27419	Full PC for a newly constructed shopping center. 10 new retail spaces, 1 story building. New undergroud service size: 800A. Total sq ft = 15296	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50704	16041-20001-25006	3355 S OVERLAND AVE	90034	5	120B161   422	4254024024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			02/22/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.02662	-118.41332	02/22/2019 Changes to an approved set of plans. All changes have been clouded. Changes throughout plan set. Loads have been revised and lighting floor plans for units have been changed.changes are noted delta 1 only.this is plan check onlyNote: Building permit has been issued under 16010-30000-02948*****Original Work Description*****New 41-unit 6-story apartment building over 1 story parking garage and 1 level sub-grade parking garage.  1200A 208Y/120V service.  100kW emergency generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50705	16041-10000-02298	11975 W BLUFF CREEK DR	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			Corrections Issued	01/21/2016 12:00:00 AM	ADDRESS	33.98224	-118.40247	**FEES AND PC FOR ENERGY ONLY, POWER PC FEES ON SUPPLEMENTAL 16041-10001-02298.  TI ON THE FIRST FLOOR OF AN EXISTING OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 19,336.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50706	10041-10000-19481	5001 W RODEO ROAD	90016	10	120B181   948	5046013900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.02168	-118.35178	TI IN A PUBLIC RESTROOM. PLAN CHECK IS FOR FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50707	19041-20000-24263	20618 W BLUEBIRD CT pv1	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.29688	-118.58274	pv1install roof mounted pv system sized 5.25KW AC interconnetced with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50708	15041-10000-24112	427 S BOYLE AVE	90033	14	127-5A221 224	5174002016	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Apartment			07/28/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.04213	-118.21983	PV2, 120KW roof mounted system for an existing apartment building; Scope includes (404) modules , (3) combiner box, and (2) inverters interconnecting through a load center Site located in Methane Buffer Zone.(((((((((((((((((((   permit fees waved due to senat bill 1222  2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50709	18041-10000-03969	6360 W 80TH PL	90045	11	099B165   714	4108026034	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	33.96605	-118.39833	Plan check for PV roof mounted  battery back up system. System size: 7.6kW with 20 modules, 1 inverter and 1 battery LG Chem.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50710	10041-10000-11875	17276 W SATICOY ST	91406	6	186B133   237	2203017045	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00, 1319.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.20826	-118.50937	"TENANT IMPROVEMENT (NON-STRUCTURAL) TO CONVERT EXISTING 1,800 SQ. FT. TENANT SPACE FROM BEAUTY SALON TO PROPOSED ""PANDA EXPRESS"" RESTAURANT (B OCCUPANCY) plan chk is for title 24 and 1 ea emergency ckt-"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50711	14041-20001-11793	15931 W VOSE ST	91406	6	183B141   296	2224008045	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.19855	-118.48039	EXPEDITE PER CUSTOMER REQUESTPV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.75KW INTERCONNECTED WITH MAIN SERVICE PANEL.(1) SOLAREDGE 5000A TRANSFORMERLESS INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50712	19041-20000-46440	16100 W MEADOWCREST ROAD	91403	5	159B141    34	2280018045	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.13603	-118.48424	PV1. INSTALL 9.10 KW DC GRID-TIED PV SYSTEM WITH (28) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50713	15041-20000-33427	21650 W OXNARD ST ste. 350	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Remodel existing office space in a high rise build. STE. 350. Some new lights, all existing ckts.PC for T-24 only. Total area: 1005 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50714	15041-20000-29075	4631 N NORWICH AVE	91403	4	168B145   789	2264013022	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.1549	-118.46085	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(29) Kyocera KU 265 Moudles(1) PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50715	19041-20001-39897	22332 W LULL ST	91304	3	186B101   134	2012020046	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	34.20852	-118.61365	Plan check for online permit - project scope is a 1.240 kW PV system addition to an (E) 7.2 kW AC PV system - total system size below 10 kW.  (4) modules with microinverters.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50716	17041-10003-43816	11356 W DONA LOLA DR	91604	2	159B173   400	2380017022	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM			Not Ready to Issue	04/06/2018 12:00:00 AM	ADDRESS	34.13224	-118.37858	Supplemental PC for lost set:NEW ROOFTOP SOLAR SYSTEM WITH 52 MODULES (SILFAB SLG-M 370 WATT) AND 52 MICROINVERTERS (ENPHASE IQ6PLUS-72-2-US). SYSTEM SIZE IS (19.24KWdc/15.08KWac).Inspection to verify that existing 200A service from DWP remains and only a new 400A panel with 200A main breaker is installed.  ZERO PERMIT FEES DUE TO SENATE BILL 1222.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50717	15041-10001-14503	12484 W OSPREY LANE 1-3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM			PC Approved	08/10/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	Changes to approved set.  Change of minihorn model to enable low frequency tones.  (((NEW FIRE ALARM SYSTEM FOR NEW 4 STORY BUILDING. SCOPE INCLUDES 37 FIRE ALARM DEVICES, 1 CONTROL PANEL AND 1 FIRE ALARM PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50718	17041-10000-31379	16744 W HALSTED ST	91343	12	201B137   916	2686022002	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.24442	-118.49739	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 54 AC MODULES(SUNPOWER SPR-X21-345-C-AC). SYSTEM SIZE 17.28KVA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50719	10041-10001-06811	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/26/2010 12:00:00 AM			PC Info Complete	08/26/2010 12:00:00 AM	ADDRESS	33.9451	-118.37436	title 24 and emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50720	18041-20000-06308	8389 N SHOUP AVE	91304	12	192B101   442	2004009002	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.22232	-118.61494	Plan check for a roof mounted pv system(14.08KVA) consisting of 43 panels with microinverters(enphase iq6)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50721	13041-10000-28875	3901 N EAGLE ROCK BLVD BLDGG	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.11925	-118.23127	"INSTALLING FIRE ALARM SYSTEM,   APARTMENT BUILDING ""G"" (7 OF 7 buildings)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50722	17041-30001-06410			14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	PIN	34.0533007	-118.2570441	Changes to approved set. Changes include change of fixture type and size. Permit to be pulled under master application.Plan check for Title 24 only. Project site is a portion of the 36th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,325 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50723	12041-20000-02382	9310 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM			PC Approved	02/01/2012 12:00:00 AM	ADDRESS	34.23949	-118.53589	Lighting revisions to 11041-20000-16167Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50724	17041-10000-36893	6200 S SAN PEDRO ST	90003	9	105B205   774	6006021014	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	33.98316	-118.26942	REPLACE OUTDOOR EXISTING FIXURE WITH NEW LED FIXURE - TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50725	19041-10000-50987	1337 W LAS FLORES DR	90041	14	163-5A227 225	5691005020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.14163	-118.19488	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3.8KWac/4.56KWdc. SCOPE OF WORK IS 16 MODULES (HANWHA 285) WITH OPTIMZERS (SP320) AND A CENTRAL INVERTER (SE3800H-US). NO MPU.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50726	14041-20000-10706	445 S FIGUEROA ST SUITE 3600	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY, <400 NEWLY CONNECTED AMPS. 11737 SQFT, EMERGENCY LIGHTING. SUITE 3600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50727	15041-20001-16305	936 S OLIVE ST UNIT 254	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #12 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50728	10041-20000-20587	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM			PC Info Complete	10/15/2010 12:00:00 AM	ADDRESS	34.07666	-118.3805	revision to 3rd floor coridoor and facade task lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50729	11041-10000-07717	5955 N DE SOTO AVE 200	91367	3	177B105    78	2149002027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM			PC Approved	04/28/2011 12:00:00 AM	ADDRESS	34.17888	-118.59071	TI TO AN EXISTING 2-STORY OFFICE BUILDING.  T-24 WITH EMERGENCY PLAN CHECK OTC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50730	15041-10000-08102	743 1/2 E PICO BLVD	90021	14	123A211    71	5132012055	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Expired	04/13/2017 12:00:00 AM	ADDRESS	34.03224	-118.25253	RETROFIT EXISTING LIGHTS TO LED WITH RETROFIT KITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50731	14041-10000-04443	12473 N GLADSTONE AVE #6	91342	7	219B161   224	2525018060	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.29658	-118.41295	Remove HID light fixtures and replace with new fluorescent fixtures in commercial storage space.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50732	14041-20000-01886	1440 W 37TH PL	90018	8	117B193   290	5041029008	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Expired	02/29/2016 12:00:00 AM	ADDRESS	34.01987	-118.30159	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50733	14041-10000-21996	4425 N KATHERINE AVE	91423	4	165B153   156	2265018018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM			Reviewed by Supervisor	09/03/2014 12:00:00 AM	ADDRESS	34.15159	-118.44336	PV1, INSTALL 3.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(12) MODULES: KYOCERA KD 255GX(1) INVERTER: POWER-ONE AYRORA PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50734	15041-10000-40117	657 N OCCIDENTAL BLVD	90026	13	139-5A203 705	5401026012	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.07842	-118.27501	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP.  TOTAL SYSTEM SIZE IS 2.0KWac. (8)MODULES-SOLARWORLD-SW 280MBLK(8)MICROINVERTERS-ENPHASE-M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50735	16041-10000-34282	539 S WESTERN AVE	90020	4	135B193   798	5503018019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	04/04/2017 12:00:00 AM		Issued	04/04/2017 12:00:00 AM	ADDRESS	34.06419	-118.30939	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT. NO CHANGE IN USE. TOTAL AFFECTED AREA IS 1267 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50736	14041-10000-28156	333 S HOPE ST 23rd &-24th floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	Title 24 plan check only. Area = 3,740 sq. ft. Commercial high rise. Changes to lighting fixtures, receptacles, exit signs, emergency lighting.UPDATE (10/27/2014): Cutsheets for all luminaires have been provided and luminaire wattage values agree with calculations on the Title 24 NRCC pages.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50737	18041-10000-38511	777 S FIGUEROA ST 38th floor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	new lighting circuits in elevator lobby/ corridorplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50738	17041-10000-13616	2619 W SUNSET BLVD	90026	13	141A205   215	5402015023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1956.00	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.0804	-118.26999	RESTAURANT TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50739	18041-20000-45092	8331 N PONCE AVE	91304	12	192B097   381	2004001018	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.22039	-118.62158	Plan check for a PV1 roof-mounted PV system. System size is 13.725 kWdc/12.24 kWac-CEC and consists of (1) 10 kWac rated inverter and (45) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50740	13041-20000-31807	10809 W HORTENSE ST 3	91602	2	168B177  1130	2421024***	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.15488	-118.3662	PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 2.7 KW AC USING MICROINVERTER NONSTANDARD PLAN. ENPHASE M215. PART OF MULTI FAMILY. WORK DONE IN UNIT 3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50741	19041-20000-48684	2088 N RIDGE POINT DR	90049	11	150B137    31	4493033***	(Q)RD6-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	PIN	34.10493042	-118.48805487	PV1.  Install 8 kW DC / 6.8 kW AC CEC roof mounted PV system.  (25) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50742	11041-10001-22035	6333 W 3RD ST STALL #112	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM			PC Approved	12/27/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	Change the approved plan. Replace existing track lighting with new LED fixtures PLAN CHECK T24 FOR EXISTING STARBUCK'S COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50743	13041-10000-10900	957 N CORSICA DR	90272	11	129B133   374	4408011010	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.04555	-118.50795	NEW HOME WITH EQUIPMENT OVER 600A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50744	18041-10000-47230	1301 S PACIFIC AVE	90731	15	012B197    78	7454026026	C2-1XL-CPIO	Harbor	San Pedro	Central San Pedro		2969.01	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Issued	12/13/2018 12:00:00 AM	ADDRESS	33.7322	-118.28811	REMOVE HID INDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50745	13041-20000-35633	4937 N TOPEKA DR	91356	3	168B121    69	2176008003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.16032	-118.54767	PC FOR PV1 SINGLE FAMILY DWELLING. THIS IS PLAN CHECK FOR THE GROUND MOUNTED PART OF THE PV SYSTEM. GROUND MOUNTED 6KW AND SERVICE MAIN SERVICE PANEL UPGRADE. refer to building department for zoning clearance	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50746	14041-10001-05917	410 N BARRINGTON AVE	90049	11	135B141    80	4429021054	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.06949	-118.47343	"""EXPEDITED PER APPLICANTS REQUEST""PV1. ROOFMOUNTED UNGROUNDED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 18.84 kW DC.(60) BOSCH C-SI m 60 265 MODULES(12) BOSCH C-SI m 60 245 MODULES(3) PVI-6000  208 VAC POWER ONE INVERTER"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50747	18041-20000-39878	7639 N SOUTHBY DR	91304	12	189B089   442	2027038047	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.21052	-118.65237	PV1.  Install a 19.5 kW DC roof mounted grid tied PV system.  (60) modules with 10 kW and 3.0 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50748	18041-30001-15382	2720 S LA CIENEGA BLVD	90034	10	123B173   637	5065012003	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.03352	-118.37567	This is supplemental plan check only due to field installation <<<Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a second story addition/tenant improvement. Total lighting area = 4,175 sq. ft.>>Note: Building application has been generated under 16014-30000-05522. Electrical permit fees have paid under 18041-30000-12982.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50749	18041-20000-46723	8247 N QUARTZ AVE	91306	3	192B117   880	2106019008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.21924	-118.5646	pv1install roof mouinted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50750	15041-20001-31352	14732 W OXNARD ST	91411	4	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.17918	-118.45422	Title 24 plan check only.  Total area = 9,260 sq. ft.  T.I. to existing low rise office space.  **Changes to an approved set: Added new lighting fixtures and added control receptacles.Permit Under 15041-20000-31352	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50751	16041-10000-02512	7800 N TEXHOMA AVE	91325	12	189B129  1003	2201028013	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.21224	-118.51524	PV1 SFD, TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 36 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50752	17041-20000-18343	5325 S COMPTON AVE 1-2	90011	9	108B209   453	5104009030	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Apartment			06/01/2017 12:00:00 AM			Reviewed by Supervisor	06/13/2017 12:00:00 AM	ADDRESS	33.99414	-118.24792	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.94 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50753	17041-20001-23033	12476 N WOODLEY AVE	91344	12	219B137    49	2605005004	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.29779	-118.49503	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (18) micro-inverters, (36) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50754	17041-10000-18813	25112 S VERMONT AVE	90710	15	036B197   219	7413020045	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Issued	06/06/2017 12:00:00 AM	ADDRESS	33.79623	-118.2906	PC for energy only, Indoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 6,250 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50755	15041-20001-30923	17120 W VANOWEN ST	91406	6	180B133    24	2230011901	[Q]PF-1XL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.19363	-118.50653	05/25/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 15. Changes include the addition of a wireway to the main distribution equipment.*****Previous Work Description*****Power plan check for service upgrade (5000-Amp, 480/277V 3phase 4-wire) and new equipment added for supporting new data center connected as a whole package load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50756	15041-10000-15770	17472 W VENTURA BLVD	91316	5	171B129   445	2290004025	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM			PC Info Complete	05/22/2015 12:00:00 AM	ADDRESS	34.16129	-118.51394	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50757	17041-10000-22261	3525 W 8TH ST	90005	10	132B193   573	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.05782	-118.30714	PC FOR POWER AND ENERGY. SERVICE 480/277V 5000A. NEW CONSTRUCTION-SEVEN  STORY TYPE III-A 367??? UNIT APARTMENT BUILDING OVER TWO LEVELS TYPE IA RETAIL/COMMERCIAL/PARKING OVER THREE LEVELS SUBTERRANEAN PARKING.NOTE: PLAN CHECK HAS BEEN APPROVED UNDER SUPPLEMENTAL 17041-10001-22261	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50758	19041-20000-21195	9000 N CORBIN AVE	91324	12	195B117    23	2783028047	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.23458	-118.56205	Plan check for PV roof mounted system for commercial building, system size: 62.5KW AC CEC, 69.9KW DC with  212 PV modules and 2 Solaredge Inverters(14.4kW and 43.2KW) connected to 1200A 120/208V Service. Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50759	16041-20000-39733	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	33.97954	-118.41361	TI TO AN EXISTING COMMEECIAL BUILDING.  ADDING NEW LIGHTING OUTDOORS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOTAGE 37936.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50760	13041-20000-35417	19332 W NORDHOFF ST	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.23457	-118.55484	OUTDOOR ENERGY PLAN CHECK PERMIT FOR 2 CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50761	18041-20000-10382	20658 W WALNUT CIR	91326	12	219B109   358	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.29421	-118.58426	PV1.  Install 3.76 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50762	15041-30000-43256	445 S FIGUEROA ST 36 FLOOR	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.05295	-118.25675	Title 24 plan check only.  Total area = 820 sq. ft.    T.I. to lobby and restroom areas on 36th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50763	18041-10001-44175	811 W 7TH ST	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM			PC Info Complete	02/01/2019 12:00:00 AM	ADDRESS	34.04908	-118.25911	All equipment fees shall be under original REVISION TO APPROVED SET T-24 ONLY delta 4 and 5 .ORIGINAL SET # 18041-10000-44175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50764	16041-10000-40818	2570 S LINCOLN BLVD #103	90291	11	108B149  1026	4236031001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.99082	-118.44789	PC for energy only to an existing buiilding. Change of us from retail to yoga studio. Installing new lighting and power. Total sqft = 2766.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50765	17041-10000-44208	1625 W 190TH ST	90248	15	060B193   387	7351001024	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	33.85851	-118.30846	Plan check for T24 only replace outdoor HID fixtures with new LED fixtures, area: 35,675 sq.ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50766	14041-20005-17303	5800 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	ADDRESS	34.09728	-118.31693	9.1.2016 - Plan check for changes to approved set. Update panel schedules and floor plans to reflect as built conditions. Removing first floor lobby lighting from scope of project. Changes clouded delta 15.=====8/18/2016Plan check for changes to approved set.  Add series rating for LA panels. Add insulated ground conductor for flex conduit.  Revised various mechanical equipment. Changes clouded delta-14. =====6/11/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 2 and Delta 3. Changes include downsizing the EM generator to 800 kW from 1000 kW, the EM distribution board has been separated to have sections, 10 new lighting control panels, the addition of 2 new civil sump pumps, addition of fire smoke damper circuits, relocation of additional circuits and upsizing of water heater circuit breakers. *****Previous Work Description*****A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50767	17041-20001-44997	327 N CHESTNUT AVE	90042	14	153A233    90	5493031004	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.11489	-118.1752	EXPEDITED PER APPLICANTS REQUESTINSTALLATION OF TESLA POWERWALL ENERGY STORAGE SYSTEM . 27 KWH +  PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.575 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50768	13041-10000-36283	7530 N GLENOAKS BLVD	91504	2	186B181   214	2401042008	(Q)C1.5-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.20763	-118.34265	PLANCHECK FOR T24 ENERGY ONLY PER INSPECTORS REQUEST. PERMIT ALREADY PULLED UNDER 13041-10000-27038. (101) SWITCHES/OUTLETS/LIGHTS ALL ON EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50769	19041-10001-07916	614 E TERMINAL WAY	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	33.74201	-118.26431	Plan check only. CHANGES TO APPROVED SET, REMOVING 1 OF THE WIRELESS CHARGING PADS AND 1 POWER CABINETS. ALL CHANGES ARE MARKED.  (((INSTALL 2 NEW EQIPMENT PADS, CABLING, RACEWAY FOR WIRELESS CHARGING OF A FUEL CELL ELECTRIC TOP LOADER RATED AT 300KW EACH.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50770	10041-10000-20141	5574 W MELROSE AVE	90004	4	141B189   337	5523022001	C2-1VL	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM	05/02/2011 12:00:00 AM		Permit Finaled	08/26/2011 12:00:00 AM	PIN	34.08334761	-118.32242338	Ti in an existing restaurant. Plan check is for T24 and emergrncy lights.  Ref.#10042-10000-19581.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50771	18041-20000-35456	5217 N ELLENWOOD PL	90041	14	163-5A221 243	5671021023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.14139	-118.21836	Plan check for PV roof mounted system and battery back up, PV system size: 5.2kW with 18 modules and 1 inverter(5.2kW), Tesla PowerWall 2.0 13.5kWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50772	10041-10000-25246	12180 W MILLENNIUM #950	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	33.97975	-118.40731	Ti in an office building in Playa vista. EPC is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50773	13041-10000-28657	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	33.79173	-118.23549	Install new 100A 480V service switchrack and related conduit for biosparging operations.  Hazardous classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50774	16041-10001-11165	3560 S MAPLEWOOD AVE	90066	11	111B149   189	4245004015	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.00336	-118.44736	04/13/16CHANGES TO AN AN APPROVED SET OF PLANS.  SCOPE INCLUDES ADDING TWO ADDITIONAL YINGLI #YL250P-29b MODULES TO EXISTING PV STRING ARRAY. NOTE: PERMIT PULLED UNDER PCIS#16041-10000-11165((((ADD TO (E) SOLAR SYSTEM: 2.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(9) MODULES: YINGLI YL250P-29B(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50775	14041-10000-23613	9743 N INDEPENDENCE AVE	91311	12	201B105   140	2746003018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.24717	-118.591	PLANCHECK FOR T24 ENERGY. REPLACE HID FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 5184 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50776	12041-10000-09244	515 S FIGUEROA ST # 1230	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.05199	-118.25764	remodeling of officesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50777	17041-20002-26760	18611 W BRYMER ST	91326	12	213B125   145	2872019031	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.28251	-118.5386	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 4.6 kWac and consists of (1) inverter and (17) modules. PV interconnection is being made onto a center-fed panelboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50778	19041-10000-18705	10563 W ASHTON AVE	90024	5	132B157  1270	4326002200	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	ADDRESS	34.06161	-118.43204	Plan check for a monitoring system with (1) fire alarm panel, and (10) devices located in a 3-story 3-unit condo.Note. Portion of permit fee is paid under application number: 19041-20000-17884.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50779	18041-20000-09192	623 S ARDEN BLVD	90005	4	135B189   912	5505014010	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.06288	-118.32599	Plan check for a PV1 roof-mounted PV system. System size is 8.4 kWac/9.75 kWdc and consists of (30) modules and (30) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50780	15041-20000-23632	16633 W VENTURA BLVD Suite 1005	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.15823	-118.49571	Title-24 plan check only.  Total area = 1,477 sq. ft.  T.I. to existing commercial highrise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50781	17041-20001-02157	23001 W MULHOLLAND DR	91364	3	165B097    72	2074038001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.15169	-118.62644	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.2 kWac and consists of (40) modules, (40) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50782	18041-20000-02154	3826 N MOUND VIEW AVE	91604	2	162B165   640	2369011015	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.14012	-118.39502	Plan check for the addition of (4) Tesla PowerWalls onto an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50783	18041-20001-23107	15300 W PARTHENIA ST	91343	6	195B145   529	2654021038	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.22812	-118.46567	10/12/2018 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the lighting and power systems and the single line diagram. All lighting changes have been reflected onto the Title 24 forms.Note: Partial electrical permit fees have been paid under 18041-20000-23107, 18041-20000-23871, and 18041-20001-23871.*****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from restaurant to dental office/tenant improvement. Total lighting area = 1,240 sq. ft.Note: Building application has been generated under 18016-20000-18113	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50784	14041-20001-29422	19765 W RINALDI ST B	91326	12	210B117   380	2701040039	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Approved	05/26/2015 12:00:00 AM	ADDRESS	34.27504	-118.56378	Changes to approved set.  Relocating loads and new Isc calculations with reduced panel AIC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50785	17041-20001-32539	7283 W PACIFIC VIEW DR	90068	4	156A181   577	2428017004	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	ADDRESS	34.12057	-118.35109	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters and (50) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50786	17041-20000-42344	1542 N CAHUENGA BLVD	90028	13	148-5A187 356	5546012004	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	05/26/2018 12:00:00 AM	ADDRESS	34.0993	-118.32935	TI to existing commercial restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50787	16041-30000-10871	14915 W ROSCOE BLVD	91402	6	192B149   371	2653023013	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.06	Electrical	Electrical	Apartment			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.22163	-118.4582	Installation of fire alarm system in new 3 story apartment building.  Total system size = 67 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50788	14041-10000-07254	2122 W BEVERLY BLVD	90057	13	136-5A205 351	5154008032	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.06682	-118.27115	PLANCHECK FOR T24 ENERGY. EXISTING RESTAURANT. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS. 755 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50789	19041-20000-32012	1999 S AVENUE OF THE STARS Stes 1550-1575	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Issued	08/20/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI to (E) commercial office in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50790	15041-10000-38861	5164 W ROMAINE ST	90029	13	144B193  1090	5537023020	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.0884	-118.30442	PV1 SFD TOTAL SYSTEM SIZE 3.12KW AC USING MICROINVERTER SYSTEM. TOTAL OF 13 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50791	16041-10000-30642	835 W JEFFERSON BLVD 7-C	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	TI FOR OFFICE SPACE IN EXISTING ROOM. NEW LIGHTING. WORK DONE IN BUILDING 7 SUITE 7-CPC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50792	18041-20000-32040	20312 W GERMAIN ST	91311	12	207B113   171	2707017002	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.26206	-118.57641	Plan check for a PV1 roof-mounted PV system. System size is 7.68 kWdc/5.76 kWac and consists of (24) micro-inverters, (24) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50793	12041-10000-28730	1801 S FIGUEROA ST	90015	9	124-5A205 281	5126002008	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2242.00	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	34.03524	-118.27179	FIRE ALARM SYSTE FOR DOWNTOWN LA MOTORS. ADDING 1 PANEL AND 5 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50794	13041-20000-14786	13283 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24 KW. 15 PANELS IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50795	16041-10000-40685	127 S SAN VICENTE BLVD 4TH FLR	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.07457	-118.37864	PC for power only. I-Occupancy. 9 Story outpatient hospital (OSHPOD 3) building,TI on 4th floor only. Scope includes new panels, motors, circuits in  13 general operating rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50796	18041-10001-40894	5733 N STANSBURY AVE	91401	4	174B153   418	2245028014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.17488	-118.44127	Plan Check fee of '0' due to department errorPC FOR ROOFTOP PV SOLAR, 9 MODULES, 5.0 KW SYSTEM, 1 INVERTER/OPTIMIZER INCLUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50797	14041-20001-10368	16742 W MARILLA ST	91343	12	201B137   485	2686006003	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.24766	-118.49732	(((expedite fees)))pv1 single family dwelling. total system size 6kw ac using transformerless inverter. nonstandard plan. using power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50798	13041-10000-19457	4518 W GAINSBOROUGH AVE	90027	4	153B197   530	5588025007	RS-1	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	34.11259	-118.28913	PV1 7.1 KW 240V MICROINV 1 STORY. STD. ROOFMOUNT.[( 33 ) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: LG 260SICG3 ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50799	14041-10001-14576	2866 W 7TH ST	90005	1	133-5A201 181	5077015008	C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.05967	-118.28596	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV2, INSTALL 12 KW DC ROF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING, UPGRADING MAIN SERVICE PANEL TO 225 A SERVICE. MICRO INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50800	13041-20000-17004	8905 N GLENOAKS BLVD BLDG A	91352	6	195B173   278	2408008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.23033	-118.36723	TI OF EXISTING SHELL. PROVIDE LIGHTING FOR TENTANT LEASE SPACE. NO BUILD OUT YET. PC FOR T24 ENERGY ONLY. WORK DONE IN BLDG A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50801	17041-10000-15292	10707 W BURBANK BLVD	91601	2	174B177   554	2415019020	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Approved	05/09/2017 12:00:00 AM	ADDRESS	34.17232	-118.36408	Title 24 plan check.  Change of use from retail to office and sound recording studio.  New 400 amp service with 4 subpanels feeding lights and receptacles.  Total area = 3,611 sq. ft.     Building permit #16016-10000-29591	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50802	17041-10002-28208	22944 W COLLINS ST	91367	3	174B097   389	2041014031	RE9-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	34.17348	-118.62707	Changes to approved set: Relocation of an array (6 panels) from one side of the roof to another. System size and design remain the same. This is plan check only, permit is covered under master plan: 17041-10000-28208<<PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS           14.4KWac.(45)AC MODULES- SPR-X22-360-C-ACNote: Fee $0 due to SB 1222>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50803	13041-10001-13637	117 E WINSTON ST #101	90013	14	129A213   226	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.04713	-118.24718	changes to the lighting system and addition of 3ph washerPlan check power and energy for time tenant restaurant suite 101. Occupancy over 100.  Title 24 Energy plan under application #13041-10000-13609	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50804	14041-30001-17560	950 S FAIRFAX AVE	90036	4	132B177   555	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.05875	-118.3633	08-31-2017 Changes to an approved set of plan. Changes include relocate electrical room and change conductors from Cupper to aluminum. Changes has been clouded.Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50805	11041-20000-18785	8736 N CANBY AVE	91325	12	195B125   748	2769025016	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM	09/23/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.22975	-118.53467	Installation of a new 250 KW generator and factory camlock unit (Phase 3).  Previously approved set of plans that show approval of phase 1 and 2 of the system are provided.  Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50806	14041-10001-05697	2472 N LAKE VIEW AVE	90039	13	148-5A209 202	5440024025	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.10193	-118.25417	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(14) MODULES: TRINA SOLAR TSM-250PA05.18(1) SOLAREDGE SE3000A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50807	12041-10004-27734	2500 S NAVY WAY Terminal-BLDG	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			11/16/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.73363	-118.2408	Modify existing fire alarm system for Pola Maersk (port of LA) 5of 6 Terminal Operation Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50808	15041-10000-28472	707 W WILSHIRE BLVD 21TH FLR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	Energy plan check for coridor and restroom located at the 21th floor of a high rise building.  Total 2793-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50809	14041-20001-04852	8419 N RATHBURN AVE	91325	12	192B125   430	2786019011	RS-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.22344	-118.53292	Fee for expedite only.*****Roof mounted PV system with 4.75KWdc.******	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50810	19041-10000-38864	1472 W VERNON AVE	90062	8	111B193   172	5016002002	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.00358	-118.30263	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE  IS 5.58KWdc / 5.00KWac.(18)MODULES-CANADIAN SOLAR 310 W(18)OPTIMIZERS- SOLAREGDGE P320(1)INVERTER-SOLAREDGE SE 5000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50811	19041-20000-07342	1880 S CENTURY PARK EAST STE 508	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.06144	-118.41437	T24 PLAN CHECK FOR EXISTING COMMERCIAL BUILDING, LIGHTING ONLY, TOTAL SQUARE FOOTAGE = 2041 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50812	17041-10000-41036	5516 N HERMITAGE AVE	91607	2	174B165   856	2347012012	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.1708	-118.40019	Permit fee is $0.00 due to Senate Bill 1222.PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND OPTIMIZERES. (60) MODULES AND (1) 11.4KW INVERTER. TOTAL SYSTEM SIZE IS 11.4KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50813	14041-20000-16769	23388 W MULHOLLAND DR	91364	3	168B093   135	2068001003	(T)RS-1XL, R3-1, RA-1, RA-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.1563	-118.63495	PLAN CHECK FOR POWER DISTRIBUTION TO MOBILE MODULES. TEMPORARY POWER TAP FROM EXISTING 3000A SERVICE TO POWER TEN MOBILE MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50814	18041-10001-34797	4222 N VINELAND AVE	91602	2	165B173  1260	2366020002	[Q]C2-2D-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.03	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.1455	-118.37004	SUPPLEMENTAL FOR CHANGES TO AN APPROVED T-24 SET. CHANGES TO TYPE OF FIXTURES F AND G WITH WATTAGE REDUCTION PER FIXTURE FROM 18W TO 14.5W. TOTAL AFFECTED AREA 5121 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50815	18041-10000-08901	1121 S DOLPHIN ST	90732	15	015B193  1021	7459017015	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	33.73392	-118.30682	Plan check for PV roof mounted system. system size: 11.4 kW with 43 modules and 1 inverter(11.4kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50816	15041-10000-04284	9817 N VARIEL AVE	91311	12	201B105   111	2746004034	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.24863	-118.59306	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL  AREA 8268 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50817	11041-10000-01382	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	33.95887	-118.41869	AT THE CUSTOM HOTEL , RELOCATE ENTRY, NEW CANOPY, NEW DRIVEWAY.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50818	15041-10003-25608	621 W 54TH ST	90037	9	108B201   539	5001026013	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	33.99338	-118.28497	NEW LAYOUT TO ALLOW FIRE SETBACKS. PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50819	17041-10000-33787	4143-4149 S BUCKINGHAM ROAD BLDG B	90008	10	114B181    79	5032014003	R3-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			09/20/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.01121	-118.34335	PC FOR 600A SERVICE UPGRADE AND REPLACEMENT OF UNIT PANELS. ALL UNIT PANEL SUBS HAVE BEEN ISSUED UNDER SEPARATE PERMITS. THIS IS PLAN CHECK FOR ALL AND PERMIT FOR SERVICE SECTION ONLY. THIS IS SERVICE 1/2NOTE: PERMIT FEES TO BE PAID UNDER INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50820	15041-10000-32678	404 S FIGUEROA ST 2nd Floor	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.05326	-118.25596	TI to an existing meeting room in a highrise hotel build. Scope of work on the 2nd floor. Total area: 5,680 sq.ftPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50821	15041-10000-40655	1123 N VINE ST #6B	90038	13	144B185   639	5533007025	C2-1D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM			PC Approved	12/03/2015 12:00:00 AM	ADDRESS	34.09139	-118.32683	**PLAN CHECK ONLY**T-24, TI OF AN (E) OFFICE SPACE IN A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL SQ. FT. 957.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50822	16041-10001-43319	5634 W SANTA MONICA BLVD	90038	13	144B193   768	5536018021	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.09063	-118.31261	01/26/16Changes to an approved set of plans. Adding/removing/relocating bug eyes from lighting floor plans, and revising emergency photometrics, Note: permit is paid under PCIS#16041-10000-43319	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50823	15041-20000-23766	7100 N COSTELLO AVE	91405	2	183B153   339	2216008009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.19953	-118.43767	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (31) modules, and (1) combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50824	13041-10000-33989	1901 S AVENUE OF THE STARS SUITE 1450	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.05949	-118.41705	Tenant improvement of office spaces in a commercial highrise building.  Newly connnected load below 400A, Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50825	15041-10000-00296	12800 N MEADOWLARK AVE	91344	12	222B133   470	2602009002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2015 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.30313	-118.5085	Plan check for PV system roof mounted, system size: 10kW with 43 modules and 1 inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50826	19041-10001-01529	2841 N MONTCALM AVE	90046	4	156B177   363	2427014002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.12301	-118.35572	EXPEDITE PER APPLICANT REQUEST.((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.35KWdc / 11.4KWac. (41)MODULES-SOLARIA POWERXT-350R(41)OPTIMIZERS-SOLAREDGE P370(1)INVERTER-SOLAREDGE SE7600A-US(1)INVERTER-SOLAREDGE SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50827	14041-20000-27222	3441 N FIGUEROA ST	90065	1	144A221   304	5446004021	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.08825	-118.21663	install roof mounted pv system sized 1.5kw interconnected with msp.(6) solar world plus sw 275 modules(1) fronius galvo 1.5kw inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50828	11041-20002-14042	15208-15222 W VENTURA BLVD	91403	4	168B145   995	2276007058	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			08/15/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.15329	-118.46435	((((8/15/2013: CHANGES MADE TO APPROVED SET OF PLANS. CHANGED LIGHTING AND ALTERED CIRCUITS AND ADDED NEW CIRCUITS. THE TOTAL LOAD HAS NOT CHANGED FROM PANEL HPR))))NEW 5-STORY MIXED USE RESIDENTIAL AND COMMERCIAL BUILDING.  50 RESIDENTIAL UNITS WITH COMMERCIAL SPACE BELOW.  FULL PLAN CHECK.    (( 50 FEEDERS CHANGING FROM al TO cu  ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50829	10041-10000-13976	1080 N WESTERN AVE	90029	13	144B193   818	5536023023	C4-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.09026	-118.30895	Central station monitoring system for medical building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50830	15041-10001-33384	5792 W JEFFERSON BLVD	90016	10	120B173   313	4205031004	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.02554	-118.37522	Supplemental to approved set.  Revised  number of service entrance conductor, size, and type (AL), added (1) 100A panel with (22) circuits for lighting and receptacles. All changes noted as Delta-4. No change on T-24.<<PC FOR POWER AND ENERGY. TI FOR WEWORK. UPGRADING SERVICE FROM 1200 A TO 2000A.  NO CHANGE OF USE( OFFICE). TOTAL AREA 27143 SQ (CONDITIONED).B# FOR CORE AND SHELL 15016-10000-10510. BUILDING APP UNDER DIFFEENT APPLICATION.>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50831	15041-20001-04722	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	(T)(Q)M2-1, MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.23162	-118.58832	07/29/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 2. Changes have been made to reflect field changes.*****Previous Work Description*****Plan check for power. New large furnace infrastructure. Emergency lighting conversion to 24 hour nightlight operation. Installation of new substation. Medium Voltage 4160/480 1000 kVA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50832	19041-10000-30305	1351 S TREMAINE AVE	90019	10	129B181   636	5083021002	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.04988	-118.34044	0$ final fees per AB1414[EPLAN]PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS NOTED UNDER DELTA #B and C, CHANGES INCLUDE RELOCATION OF EQUIPMENT, INVERTER SIZE, AND ADDITIONAL DISCONNECT  ORIGINAL PERMIT #19041-10000-23238	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50833	16041-10000-01681	2544 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.10357	-118.25901	PC for energy only to a Wells Fargo bank. New lighting, new receptacles, new electrical equipment installed less than 600 Amps. Total Sq ft = 2481	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50834	16041-20000-17875	23021 W ELKWOOD ST	91304	12	189B097   787	2014028016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.21271	-118.62866	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50835	14041-10002-30103	314 W 6TH ST	90014	14	129A211   159	5144003016	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	05/19/2022 12:00:00 AM	ADDRESS	34.0468	-118.25247	SUPPLEMENTAL CHANGES TO APPROVED SET CHANGES APPLY TO CLOUDED AREAS. SCOPE OF WORK INCLUDES RELOCATION OF DWP TRANSFORMER TO BASEMENT AND VOLTAGE CHANGE FROM 480V TO 208 V, ADDITION OF NEW EQUIPMENT(FIRE PUMP) SWITCHBOARDS, AND CIRCUITS. NO CHANGE IN LIGHTING AND RESIDENTIAL UNITS.<<<Full plan check for power and energy for a mixed use building including (10) commerical tenants in the first floor and 50 units appartments on the 2nd -6th floor.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50836	19041-20001-44822	3485 S SAWTELLE BLVD	90066	11	117B157   389	4249026027	R3-1, [Q]R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM			PC Approved	11/20/2019 12:00:00 AM	ADDRESS	34.01702	-118.42433	Revisions to approved set of plans.  Reconfiguration of controlled receptacles in offices, removal of daylighting controls in non-required areas.  Subpanels changed from (N) to (E).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50837	15041-10000-32457	6033 S CENTRAL AVE	90001	9	105B209    92	6007007022	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			Reviewed by Supervisor	10/06/2015 12:00:00 AM	ADDRESS	33.98492	-118.25673	PV2, roof mounted solar system 159.250kW DC  on (E) 3 story storage build. (612) Modules: SW 260 Poly(5) inverters: (4) CPS SC28KTL-DO/US-480, and (1) CPS SC23KTL-DO/US-480(1) solar subpanel(1) AC Disconnect	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50838	15041-20000-05457	7947-7951 W FOOTHILL BLVD	91040	7	204B193    29	2556027028	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM			PC Approved	02/25/2015 12:00:00 AM	ADDRESS	34.25979	-118.30648	Title 24 plan check only.  Total area = 935 sq. ft. (building A) + 1,101 sq. ft. (building B)T.I. to two existing retail spaces located on the same lot.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50839	16041-30000-43756	801 S FIGUEROA ST 18th Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the 18th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 5,285 sq. ft.Note: Building application has been generated under 16016-30000-29870	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50840	18041-10000-14243	6922 W HOLLYWOOD BLVD 11TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	TI IN AN EXISTING RESTROOM ON THE 11TH FLOOR. INSTALL NEW LIGHTS AND CONTROLS.TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50841	18041-10000-31888	8829 W NATIONAL BLVD	90034	10	123B169  1385	4312015005	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.02913	-118.3864	FULL PC FOR POWER AND ENERGY FOR FIRST TENANT IMPROVEMENT IN AN OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10,385 SQ. FT. B#18016-10000-22302	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50842	18041-10001-21550	1047 S WINDSOR BLVD	90019	10	132B189  1130	5082019021	R1-1-HPOZ	Central	Wilshire	Olympic Park		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2018 12:00:00 AM			PC Approved	06/22/2018 12:00:00 AM	ADDRESS	34.05437	-118.32621	**Expedited per applicantInstall new PV1 rooftop solar system 7.6 kW AC (25) modules, (1) inverter. System includes (1) ESS under separate application#	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50843	11041-10000-04702	6733 N BAKMAN AVE	91606	2	180B173    65	2319007015	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	Apartment			03/10/2011 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Expired	04/02/2013 12:00:00 AM	ADDRESS	34.19319	-118.37807	Installing one F.A panel , 1 smoke detector , ann and communicatoe panel in a two story apartment BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50844	19041-20000-23045	11767 N CHIMINEAS AVE	91326	12	216B125   286	2870019035	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.28508	-118.53351	Plan check energy storage system, installed 2 power wall2.0 (13.5KWh). Battery Back Up System size: 27KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50845	19041-20000-15614	3034 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50846	17041-20000-32413	4806 N LAUREL CANYON BLVD	91607	2	168B165   456	2355010023	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.15809	-118.39628	Tenant improvement for new fast food restaurant.  Plan check for energy - 905 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50847	16041-20000-30884	3624 S 5TH AVE	90018	10	120B189  1373	5044030021	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.02208	-118.32226	PV1.  6 KW PV SYSTEM ADDITION TO AN EXISTING SYSTEM 2.4 KW PV SYSTEM.  (24) MODULES WITH (1) 6 KW RATED CENTRAL INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50848	15041-20005-30865	687 S HOBART BLVD	90005	10	132B193   184	5093006033	(T)(Q)C2-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM			PC Approved	05/03/2018 12:00:00 AM	ADDRESS	34.0605	-118.30557	05-03-2018 Changes to an approved set of plan, changes include relocate panel EM1 feeding from HL8 to HL9. Changes has been clouded as delta 4. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50849	11041-10000-17567	600 W 7TH ST #310	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	INSTALLATION OF A REDUNDANT 400KW UPS SYSTEM- ONE SUPPLIED FROM THE UTILITY AND THE OTHER FROM EXISTING NON-LEGALLY REQUIRED STANDBY GENERATOR IN SUITE #310.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50850	18041-10000-15016	14001 W OSBORNE ST	91331	6	195B153   210	2642031021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.23346	-118.43824	PC FOR  POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO I 2.1 AMBULATORY OCCUPANCY.SCOPE INCLUDES NEW SERVICES AT 800A 120/208 3PH WITH NEW AND EXISTING PANELS, NEW CIRCUITS AND EQUIPMENT.  TOTAL AFFECTED AREA 38129 SQ. FT. B# 17016-10000-29190	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50851	18041-20000-18918	1100 S GLENDON AVE 14TH FLOOR	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Issued	06/11/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	Minor tenant improvement in (E) commercial highrise building involving new receptacles, water heaters, and downlights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50852	18041-10000-33110	331 N FRIES AVE	90744	15	027B205    31	7418021036	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.77348	-118.26471	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50853	16041-10001-39353	524 S SPRING ST	90013	14	129A211   182	5149036010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Closed	06/06/2017 12:00:00 AM	ADDRESS	34.0467	-118.25006	CHANGES TO APPROVED SET OF PLANS. ADDED 3 PHASE PANEL TO SCOPE OF WORK. CHANGES NOTED DELTA 2 ON PLANS. UPDATED HOME RUNS AND PANEL SCHEDULES. ADDRESS HAS BEEN UPDATED ON THIS PLANSET	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50854	13041-10000-28420	5111 N DAHLIA DR	90041	14	162A227    42	5669013005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.13998	-118.19984	24-hour emergency medical dispatch call center renovation.  New generator for continuity of operations.  Title 24 plan check only for lighting.  Newly connected load less than 400 A.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50855	10041-10001-06234	300 S DOHENY DR 2nd Floor	90048	5	138B169   549	4335015050	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM			PC Approved	06/29/2010 12:00:00 AM	ADDRESS	34.07343	-118.38954	Suppl Application for changes to approved Plan check for T-24 Energy outdoor fitness area on 2nd floor (Pool Deck).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50856	18041-10000-32759	8309 N TUJUNGA AVE	91352	6	192B169   460	2632010007	M1-1-G-CUGU, M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.22179	-118.37924	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50857	16041-10001-19204	427 W 5TH ST	90013	14	129A211    12	5149028012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.04937	-118.25245	RE-PLAN CHECK FOR A LOST RTI SET FOR A NEW MEHTHANE GAS DETECTION SYSTEM. SCOPE INCLUDES 30 DEVICES AND 1 CONTROL PANEL.NOTE: MASTER APPLICATION IS UNDER PCIS#16041-10000-19204	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50858	17041-10000-06857	725 S FIGUEROA ST 33th Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only in existing space, office T.I. in high-rise building. Total area: 3,789 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50859	10041-20000-15671	10250 W SANTA MONICA BLVD #1040	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Adding panel and power and lighing in retail store SPACE #1040 . P/C is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50860	16041-20001-26073	23155 W DOLOROSA ST	91367	3	174B093   425	2042003075	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.17022	-118.63168	Expedite per applicant request. {{{{{Plan check for PV roof mounted system. System size: 11.5kW with 53 modules and 1 inverter(11.5kW) connected to 400A Service}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50861	13041-20000-26127	15611 W KALISHER ST	91344	12	213B145   219	2662008004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.27677	-118.47214	PV1 TRANSFORMERLESS SYSTEM. 2.53 KW. 11 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50862	13041-20000-21645	1159 N SOMERA ROAD	90077	5	144B145    36	4369031030	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Expired	08/30/2023 12:00:00 AM	ADDRESS	34.09426	-118.45845	Plan check for new house. 600A service. NOT METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50863	11041-10000-11508	5455 N VAN NUYS BLVD	91411	4	174B149  1115	2249003019	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM	06/06/2011 12:00:00 AM		Issued	06/06/2011 12:00:00 AM	PIN	34.1700491	-118.44918751	T.I  For Infinity car dealership.  Additon of new lights in new pace.  Plan check is T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50864	19041-10000-50735	20500 W NORDHOFF ST	91311	3	195B109    84	2780001049	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Issued	12/10/2019 12:00:00 AM	ADDRESS	34.23165	-118.58008	T-24, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES REPLACEMENT OF INDOOR AND OUTDOOR FIXTURES TO LED. TOTAL INDOOR SQ. FT. 18918 AND OUTDOOR SQ. FT. 20825.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50865	16041-20000-45806	2813 W SUNSET BLVD	90026	13	141A205    52	5402001020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Closed	08/06/2021 12:00:00 AM	ADDRESS	34.08208	-118.27184	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 1271	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50866	10041-20000-25190	5750 W WILSHIRE BLVD 2nd floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.06227	-118.3542	T.I. for a high rise building in office spaces 2011 to 2013 as shown on plans.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50867	14041-10001-28084	899 S FRANCISCO ST	90017	14	129A207   155	5144023054	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.04731	-118.2643	Changes to an approved set. Adding two 1000 amp distribution board for two tower with  18 skids and 25 tower crane..original approved set to be dropped off at electrical desk.<<<5,000 amp temp power for new hotel buildings with temp distribution equipment.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50868	14041-20001-28799	11430 W BURBANK BLVD	91601	2	174B169   839	2350004033	C4-1, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.17184	-118.38	05/18/2016 Changes to an approved set of plans. Changes have been made to the eletrical room layout, AIC rating of distribution boards and breakers/fuses, and redistribution of load due to the electrical room layout change. All changes have been clouded and marked as Delta 1.*****Previous Work Description*****NEW MIX USE APARTMENT BUILDING (2) SERVICES (1) 2000 AMP SERVICE (1) 1200 AMP SERVICE FIVE FLOORS WITH ONE UNDERGROUND PAKING LEVEL.  125 UNITS.  PLAN CHECK FOR POWEER AND ENERGY.Note: Variance to separate fire alarm plans submitted on 10/17/14.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50869	15041-20000-14837	13400 N GLENOAKS BLVD	91342	7	225B145   115	2502028020	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM			Reviewed by Supervisor	06/03/2015 12:00:00 AM	ADDRESS	34.31591	-118.46014	Plan check for PV roof mounted 13.8kW system with 53 modules (Kyocera) and 2 inverters(5.0kW and 6.0kW) connected to load center 125A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50870	19041-20000-42329	11321 N ENCINO AVE	91344	12	213B129   401	2711003015	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Issued	10/17/2019 12:00:00 AM	ADDRESS	34.2764	-118.51552	Plan check for PV roof mounted system, PV system size: 14.4KW DC, 13.092KW AC CEC with 36 AC Modules, new sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50871	13041-20000-31183	14530 W SYLVAN ST	91411	6	178-5A151 156	2241012024	[Q]C1.5-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.1845	-118.44983	PC FOR T24 ENERGY ONLY. TOTAL AREA 240 SQ FT.  EXISTING OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50872	15041-10000-27730	929 N HOBART BLVD	90029	13	144B193  1312	5535024019	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.08714	-118.30524	PV 2 roof mounted solar, 3.975 kW system.(15) modules: KYOCERA # KU2656ZPA(1) inverter: ABB #PVI-3.6-OUTD-S-US-Z-A*NOTE: Building has multiple meters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50873	13041-20002-35882	447 N FAIRFAX AVE	90048	5	141B177  1285	5527031018	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	PIN	34.07945639	-118.36178388	PLANCHECK FOR T24 ENERGY.  2008 T24 COMPLIANCE. PLANCHECK TO MATCH INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50874	11041-20000-12004	10880 W WILSHIRE BLVD 1005	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	06/10/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.05885	-118.44283	TI IMPROVEMENT TO AN EXISTING 25-STORY OFFICE BUILDING.  T-24 PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50875	19041-20001-03823	14200 W MULHOLLAND DR	90077	5	159B153   229	4379032011	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	34.13029	-118.44235	Revision to approved plans.  Additional disconnecting means.  (((addition of (2) tesla powerwalls(battery) 5KW each to an existing pv system.  plan check for power only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50876	15041-20001-34585	10430 N SEPULVEDA BLVD	91345	7	207B145   770	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.26014	-118.46701	"6.27.2017 - Plan check for modifications to approved set. Changing feeders from copper to aluminum + delta J clouded changes ONLY. ""PAD A"".=======PC FOR POWER AND ENERGY FOR A RETAIL SHELL BUILDING. TOTAL AREA 3750 SQ FT(CANOPY AREA).BUILDING # 15010-10000-03495"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50877	15041-20000-25592	11140 N YOLANDA AVE	91326	12	210B121   215	2717004009	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.27271	-118.54404	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (35) panels, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50878	12041-10000-16938	780 N SWARTHMORE AVE	90272	11	126B125   117	4412009031	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	ADDRESS	34.04464	-118.52629	PLAN CHECK T24 ENERGY FOR OFFICE SPACES ON THE 1ST AND 2ND FLOOR ON EXISTING PRIVATE SCHOOL. PERMIT FOR RELOCATION OF EXISTING LIGHT FIXTURES, INSTALL NEW FIXTURES, RECEPTACLES, SWITCHES, AND POWER FOR HVAC UNIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50879	12041-20000-18622	7401 N SHOUP AVE	91307	12	186B101   532	2022019023	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM			PC Info Complete	08/08/2012 12:00:00 AM	ADDRESS	34.20486	-118.61489	Installing two new panels and 16  AC units.  The assumed fault current at the 400 ampere 3 phase 3 wire service was 100,000 amps.  Calculations show the available fault current at the panel AC1 is 36000 amps with motor contribution of  1830 amps.  The circuit breakers in the new panels shall be fully rated for 65 KAIC JD6-A, and 42 KAIC QJ2H.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50880	11041-20000-12586	21021 W VENTURA BLVD #101	91367	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM	06/17/2011 12:00:00 AM		Permit Finaled	07/08/2011 12:00:00 AM	PIN	34.16705846	-118.59120236	T.I. to existing space (New York Deli).  Install general/emergency lighting in dining/food prep. area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50881	15041-10000-21056	1546 N WESTERN AVE	90027	13	148-5A193 329	5544022052	[Q]R5-2	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.09961	-118.30907	Design build: laundry remodel/tenant improvement.  (2) (E) single phase services.  (2) new panels.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50882	13041-10000-30114	7822 N QUARTZ AVE	91306	3	189B117   727	2106029016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.21279	-118.56395	PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 22 modules HANWHA # HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50883	18041-20000-28644	"19350 W NORDHOFF WAY ""E"""	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Info Complete	07/31/2018 12:00:00 AM	ADDRESS	34.23523	-118.55518	Plan check for Title 24 Energy only in existing space T.I. to Art Studio. Total area: 3184 sq ft. B#18016-20000-09109	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50884	17041-20000-08271	21777 W VENTURA BLVD #D	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.16858	-118.60238	ti to an existing commercial building.  adding new lighting new controls to new panel.  newly connected load <400 amps.  plan check for energy only.  total square footage 485.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50885	17041-10000-43061	359 S BROADWAY	90013	14	130-5A211 156	5149015023	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.0498	-118.2494	PC FOR CONDO MOCKUP TI IN EXISTING SPACE. TOTAL AFFECTED AREA 1830SQ. FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.B#17016-10000-20268	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50886	11041-20001-01324	19900 W PLUMMER ST	91311	12	198B113    85	2761040010	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM			PC Approved	06/06/2011 12:00:00 AM	ADDRESS	34.24259	-118.56723	Modification to an existing approved set of plans.  Reduction in the number of different light fixtures that are being installed.  Plan check is for Title 24 only.  <<<<<<PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR PHILIPS GRAD. INSTITUTE. WORK ON ELECTRICAL WIRING ON EXISTING CKTS. NO NEW LOAD ADDED.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50887	12041-10000-01570	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.10229	-118.33907	TI in the common area and the candy shop(suite 201). EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50888	14041-20000-08830	7118 N FAIR AVE	91605	2	183B173   127	2319022009	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.19994	-118.37482	Permit to be pulled at EPC counter only. Plan check for energy only as requested by inspector. Less than 400A. 1 story BLDG# 13016 40 22927: TI--FOR NEW OFFICE SPACE WITHIN (E) WAREHOUSE. changes on plan: added occupancy sensors to <250SF offices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50889	11041-20000-25858	970 W 190TH ST	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM			Corrections Issued	12/05/2011 12:00:00 AM	ADDRESS	33.85812	-118.29302	Per Inspector:   Existing office space.  Plan check is for energy only.  Aplicant already has a permit under 11041-90000-23347	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50890	18041-10000-21716	2628 S BRIGHTON AVE	90018	8	123B193   735	5053035031	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.03175	-118.30133	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50891	18041-30000-04306	11702 W VICTORY BLVD	91606	2	180B169  1215	2334006036	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.1865	-118.38806	Plan check power and energy for OSHPD 3  First Time Tenant  Dialysis Clinic. Total area:12,061 sq ft18016-30000-03731	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50892	16041-20000-02031	"4151 W PROSPECT AVE BLDG ""N"""	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Info Complete	02/01/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for power and energy. TI to existing commercial building (offices).  Adding new lighting. Work includes 1 new 600A board and 7 HVAC units. Total sqft. 6,279.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50893	19041-10000-38290	1515 W 190TH ST Ste. 190	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	Energy PC only for Tenant improvement on approx. 1570 SF of total floor area. New non-load bearing interior partitions and finishes. No change in use or occupancy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50894	18041-10000-07101	777 S FIGUEROA ST Suite 1950	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	PC for T24 only. Installing one new light, receptacles and equipment in NERA idf closet. Total 45 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50895	12041-10001-20350	5755 W 96TH ST	90045	11	093B169   128	4125021024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	33.94955	-118.38214	ELECTRICALSERVICE  UPGRADES FOR  THE 1ST FLOOR PRODUCTION AREANOTE THAT # 12041-10000-20345 IS FOR THE TI WORK(((((( 1-9-13   changes made to previously approverd set, cable pull calc.,  temp calcs, and shrt ckt protections.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50896	10041-10000-10197	3021 N ROSSLYN ST	90065	13	156B209   198	5459003005	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.01	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM			PC Info Complete	05/28/2010 12:00:00 AM	ADDRESS	34.12146	-118.25139	Replacing existing lights in the gym. Plan Check is for title 24 energy calcs. Emergency light existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50897	17041-10000-40710	1196-1204 W 35TH ST	90007	8	120B197   819	5040018004	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			11/09/2017 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	04/20/2022 12:00:00 AM	ADDRESS	34.02403	-118.29441	FULL PLAN CHECK FOR NEW 15 UNITS OF APARTMENT, 1200A 120/208V SERVICE, TOTAL INDOOR+OUTDOOR AREA: 30,434 SQ.FTB# 17010-10000-04375	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50898	13041-10000-04029	8435 N LURLINE AVE	91306	12	192B109   401	2780007015	(T)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	06/17/2013 12:00:00 AM	ADDRESS	34.22334	-118.58427	PV1 SINGLE STORY.  10 KW INSTALLATION.  50 MODULES - CENTRAL INVERTER  {MODULE: TRINA SOLAR TSM-240PA05} {TRANSFORMERLESS INVERTER: POWER-ONE AURORA PVI-5000-OUTD-US}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50899	14041-10000-25217	2029 S CENTURY PARK EAST Suit #400	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	Title 24 and emergency lighting for 4 th floor  Suit 400 , high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50900	10041-20000-05224	6100 N SEPULVEDA BLVD	91411	6	177B145   597	2242025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	03/23/2010 12:00:00 AM		Permit Finaled	08/23/2010 12:00:00 AM	ADDRESS	34.18076	-118.46437	INSTALLING LIGHTING AND SOME RECEPTACLE FOR PRE MANUFACTURED HEARING AIR BOOTH INSIDE COSTCO STORE. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50901	15041-10000-17624	8005 W FOOTHILL BLVD	91040	7	204B193   130	2556026017	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM			PC Approved	06/08/2015 12:00:00 AM	ADDRESS	34.25982	-118.30729	PLAN CHECK FOR ENERGY ONLY FOR EXISTING 1194 SQRFT RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50902	19041-10000-19556	15401 S FIGUEROA ST	90248	15	072B201   141	6120027006	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	10/06/2021 12:00:00 AM		Permit Finaled	06/20/2023 12:00:00 AM	ADDRESS	33.89164	-118.28318	$0 FEE per AB1414 PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 810 MODULES (Q-PEAK 390), 406 OPTIMIZERS (P850 ), 2 INVERTERS ( SE 99.9K), 1 INVERTERS (SE 20K) AND 1 INVERTERS ( SE 33.3K). SYSTEM SIZE IS 253.1KWac AND 315.9KWdcPERMIT FEE IS $0.00 IN ACCORDANCE WITH AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50903	15041-20001-13515	6316 N TOPANGA CANYON BLVD STE B-1150	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	08/27/2015 Changes to an approved set of plans. Changes include the addition of receptacles to the cashwrap and the gift registry.*****Previous Work Description*****Plan check for power and energy first time tenant Sur La Table at Village at Westfield Topanga.  Total area: 5317 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50904	15041-10000-37320	424 W PICO BLVD	90015	14	126A207   175	5134017032	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.03913	-118.26523	install new FaA system for a 7-story apartment building. 5 control panel, 1  fa panel, 1 communication panel, 486 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50905	16041-10000-37422	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.17705	-118.6144	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SITE SCOPE INCLUDES REPLACING A SIGN LIGHT FOR OUTDOOR USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50906	16041-20000-41299	3217 S CLUB DR	90064	5	123B165   512	4316026014	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.03398	-118.40209	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP. Derating main breaker to 175A. 11.4kW ungrounded system. (45) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50907	12041-10000-17850	1875 S CENTURY PARK EAST Plaza	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.06115	-118.41457	Plan check for energy and emergency lighting. Ground floor of high rise building (plaza level). 730 sqft. Copy center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50908	10041-10000-20821	12500 N GLADSTONE AVE	91342	7	219B161   168	2525019062	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.29734	-118.41327	This is a lab for manufacturing wafers for micro chips.  hazardous area. (variance for a separate fire alarm system should be filed)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50909	11041-10000-15316	22401 W VENTURA BLVD	91367	3	171B101    32	2040024023	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Expired	08/14/2013 12:00:00 AM	PIN	34.16896771	-118.61498442	T.I.  Existing 7-11.  Replacing 27 light fixtures using the existing branch circuits in the retail area of 7-11 only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50910	10041-10000-21843	3050 W PERLITA AVE	90039	13	151-5A211  38	5436032017	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	01/01/2013 12:00:00 AM	ADDRESS	34.11136	-118.24963	small ofice part of residentail. title 24 energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50911	17041-10001-16577	1736 S NEW HAMPSHIRE AVE	90006	1	126B197   505	5075017007	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.04156	-118.29227	Plan check for power and Title 24.  New two story retail building.  New 1,200 amp 120/208 volt service.  New electrical distribution system on this property to feed existing distribution panel at 1743 S. Vermont Ave.  Total area = 13,430 sq. ft.     Building permit #17010-10000-00433	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50912	19041-30000-17552	1901 N ECHO PARK AVE	90026	13	142-5A211  34	5420022023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.10	Electrical	Electrical	Apartment			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	10/27/2020 12:00:00 AM	ADDRESS	34.0864	-118.25188	Plan check for a fire alarm system for a 4-story, 13-unit apartment building. Fire alarm consists of (1) FACP and (50) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50913	19041-20003-28143	3860 S 3RD AVE pv1	90008	10	117B189  1008	5034017047	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.01608	-118.32022	Revision to approved set for 5.58 kW DC roof mounted PV system.  Change of roof layout details.  Change of module string details: (2) strings of 9 modules each modified to (1) string of 18 modules.  (2) extra trip fees per inspector correction notice.  (((pv1install roof mounted pv system sized 5.58KW DC interconnected with msp.this is an addition to an existing system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50914	18041-20000-35971	515 S FIGUEROA ST ste 1470	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	ti to an existing commercial building (high rise).  adding new lighting new controls to existinbg panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50915	17041-10003-44843	8500 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	06/05/2018, Changes to an approved set of plans, changes include the revision of lighting fixtures, circuits and addition of a new panel.  Note Changes on delta 1. _______________PC for power and energy for TI comercial medical facility (Located in suite 130). Connecting new 600A DBA and 400A DBB to existing electrical Dist. board. Installing distribution board, new panels, 218kVA generator, two transformers, lights and receptacles.  Areas includes donor rooms for blood extraction, bone marrow collection, and labs. No patient treatment is provided in this facility. Total area is 37003sqft. B# 17016-10000-37033.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50916	17041-20000-41826	15250 W VENTURA BLVD Suite 1102	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.15351	-118.46549	Plan check for Title 24 only. Project site is the 11th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,133 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50917	10041-10001-06335	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			Plans on Hold	04/08/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	Change the approved plan, Change the switchboard elevation, addition of mid-voltage X-former. EPC is for delta3. Methane zone.    (((((((((((((New office/gym building with two stories.  Plan check for energy and power. (Methane zone)))))))))))  <<<<<<PER APPLICANT'S REQUEST PUT ON HOLD.  APPLICANT WILL REQUEST FOR REFUND>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50918	14041-20006-08514	6801 W HOLLYWOOD BLVD #170	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.10229	-118.33907	3/4/2015 Changes to an approved set of plans. Changes include the merging of the rotunda lights onto the perimeter lighting circuit. Changes are the same for the first and second floor. All changes have been clouded and marked as Delta 11 and 12.Change to approved set by removing ,and adding light fixture and receptical outlets; all changes are under delta-9. (((((8/22/2014 - Changes made to approved set.  Deleted low voltage timeclock override switches 'SLV1' and 'SLV2'.  Updated lighting control riser diagram and title 24 forms to relect changes.  Changes marked with delta 8))Master permit work description:  T.I. to existing retail space for Shoe Palace.  Install new general/emergency lighting.  Plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50919	16041-30000-17307	4081 S HILLCREST DR	90008	10	114B181    47	5030019010	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.04	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01207	-118.34849	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01098	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50920	19041-10000-30403	345 E 51ST ST	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles	Zapata-King		2293.00	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM			PC Info Complete	08/06/2019 12:00:00 AM	ADDRESS	33.99665	-118.26853	PC for T24 only, scope of work is upgrading public restrooms, scope of work includes new lighting, controls, and receptacles. Total affected area is 316 sfqt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50921	14041-20001-07928	6203 N RADFORD AVE	91606	2	177B169   351	2334009059	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.18324	-118.39228	Fee for expedite only.*****Roof mounted PV system with tranformerless.  System size 4.5KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50922	13041-20000-19119	16760 W TIM LANE	91406	6	180B137  1008	2231018***	RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.19341	-118.49827	PV1 TRANSFORMERLESS SYSTEM. 4.41 KW SYSTEM WITH 18 PANELS AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50923	13041-10000-02248	1600 N VINE ST 7-10 Floor	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			01/29/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.1	-118.32647	TI for apartment 7-10th floor common area lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50924	15041-20001-05323	16996 W STRAWBERRY DR	91436	5	165B133   538	2292008026	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM			PC Approved	04/02/2015 12:00:00 AM	ADDRESS	34.14475	-118.50276	Supplemental application for expedite feesInstallation of new roof mounted solar PV microinverter array.  Total system size = 9.9 kWac. 3 branch circuits with 36 modules total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50925	17041-10000-29836	12821 S FIGUEROA ST	90248	15	081B201   294	6132003022	M2-1VL-O, P-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	33.91563	-118.28297	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50926	11041-10000-21165	5303 N SAN FERNANDO ROAD WEST	90039	4	165B201   170	5593009024	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM	10/04/2011 12:00:00 AM		Permit Finaled	10/19/2011 12:00:00 AM	ADDRESS	34.14851	-118.27339	NEW LUMINAIRES IN  WAREHOUSE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50927	13041-10000-27849	500 WORLD WAY T5-INFLIGHT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Public Safety Only			10/07/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	33.94248	-118.40461	TENANT IMPROVEMENT IN OFFICES PLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS. SCOPE OF WORK IS < 400A . PLAN-CHECK ONLY PER SUPERVISOR. PERMIT TO BE PULLED @ THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50928	18041-10001-28977	401 E 7TH ST	90014	14	127-5A211 284	5148024026	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			03/18/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.04196	-118.24829	DELTA 2 CHANGES TO AN APPROVED SET. ADDITION OF A NEW EM GENERATOR TO REPLACE THE 90 MINUTE INVERTER. CHANGES ALSO INCLUDE THE REMOVAL OF THE FIRE PUMP AND FIRE PUMP METER SECTION AND ONE NEW CIRCUIT TO ALL UNITS.  ALL CHANGES ARE CLOUDED UNDER DELTA 2. original scope of work: (((PC FOR NEW 6-story, 99-unit, affordable housing apartment building.NEW 2500 120/208 3PH SERVICE.  TOTAL AFFECTED AREA 27319 SQ. FT  (INDOOR + OUTDOOR)ONE TYPICAL UNIT WITH  SINGLE MANAGER UNIT.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50929	11041-10003-23452	20600 W VENTURA BLVD South-1-217	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			03/28/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	DELTA 10 CHANGES TO PERMITTED SET OF PLANS.ATTACHED TO THE PLANS ARE LISTS OF THE CHANGES.The garage site is included in plan.South Building of a New 217 unit Apartment building.  Building Permit is on 11010-10000-01956	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50930	19041-20000-15369	555 S FLOWER ST 36th flr	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	ti to an existing high rise building.  adding new lighting new controls to existing panels.  plan check for indoor and outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50931	15041-20000-06493	500 N KENTER AVE	90049	11	135B137   189	4494018009	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.06804	-118.48592	Plan check for ground mounted PV system with 17 modules(Sunpower SPR-E20-327) (1) 6k inverter(PVI-6000-OUTD-US)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50932	14041-20000-10777	13987 N WALLABI AVE	91342	7	231B161   145	2582025045	RE11-1-H	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.32601	-118.40899	pc for 3kw pv system. using transformerless inverter. nonstandard plan. PV1, single family. 12 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50933	14041-20000-12003	12650 W SANDHILL LANE Unit 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.9774	-118.4142	Roof mounted PV system with system size 1.38KW.  Using transformerless inverters.  This part of a series set of submittal.  This PV system to interconnect to common service.  This is project 1 of 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50934	16041-10000-06696	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	33.96577	-118.42406	T-24 TO A BATTING CAGE IN A BASEBALL FIELD, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES FOR INDOOR AND OUTDOOR. TOTAL SQ. FT. 1235.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50935	13041-20001-28266	5961 N LUBAO AVE	91367	3	177B113   131	2153003022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.17929	-118.56748	(((CHANGES MADE TO MODULES ORIENTATION AND EQUIPMENT RELOCATION)))PV1 SINGLE FAMILY DWELLING. roof mount SYSTEM. NO SOLAR CAP APPLICABLE. TOTAL SYSTEM SIZE 10KW AC USING 2 TRANSFORMERLESS INVERTERS AND 30 MODULES. 400A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50936	15041-10001-26228	3310 S MORGAN AVE	90011	9	115-5A213 190	5117010003	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.01045	-118.24484	PV1 ROOF MOUNTED SOLAR SYTEM FOR A SINGLE HOME FAMILY DWELLING. (1) INVERTER 3.8 KW AND (11) MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50937	19041-20000-30934	765 W 20TH ST	90731	15	012B197  1153	7462021006	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2972.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	33.72596	-118.29375	PV1.  Install 3.96 kW DC / 4.66 kW AC roof mounted grid tied PV system and 13.5 kWh energy storage system. (12) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50938	18041-10001-09101	316 W 2ND ST	90012	14	130-5A211  19	5149009024	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			PC Approved	05/09/2018 12:00:00 AM	ADDRESS	34.05265	-118.24741	SUPPLEMENTAL TO CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE UPDATING LIGHTING SYSTEM AND T24 DOCUMENTATION, ALL CHANGES NOTED UNDER DELTA 3PC for T24 only for new lighting for penthous/ office space. Installing new lights and receptacles. Total area 2215sqft. B# 18016-10000-07276.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50939	15041-20000-26363	201 N FIGUEROA ST 7th FLOOR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI to existing commercial building (offices). Plan check for t24 energy only. Adding new lighting including emergency. Total sqft. 12,215. 7TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50940	14041-10003-34822	1842 N CHEROKEE AVE	90028	13	150A185   300	5547004019	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			05/26/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.1044	-118.33463	Applicant lost correction sheet. Resubmitting plan check for power and energy.>>>>>>>Power plan check for  (8)  guestrooms located at the basement from  a 5-story apartment with new service upgrade from 400-Amp to 600-Amp. all (8) guestrooms are typical.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50941	15041-10001-30516	12700 W MILLENNIUM #16	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	33.97639	-118.41499	Expedite per applicant request(((PV1 3kW AC (AC MODULE) roof-mounted system with (12) modules and one load center interconnecting through the main service.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50942	15041-20000-11268	10825 W ROSE AVE	90034	5	120B161   598	4254017034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.02537	-118.41643	Plan check for a PV2 roof-mounted PV system. System size is 14 kWac and consists of (66) modules, (2) inverters, and (1) 100-amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50943	19041-20000-52863	7854 N YARMOUTH AVE	91335	12	189B129   803	2101036011	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.21361	-118.51953	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 6.6 KW DC/6.172 KW AC. SCOPE OF WORK CONSISTS OF (20) PV MODULES AND A 6 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50944	17041-10000-32034	300 W WORLD WAY TERMINAL 3-#338	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	"Install new sign lights on terminal 3 ste. #338, sign reads ""Hudson LAXPRESS"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50945	19041-10000-13396	2021 S FLOWER ST	90007	9	123A205    48	5126007008	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.03188	-118.27222	plan check for title 24 only for change of HID to LED lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50946	11041-10000-25906	1714 N LAS PALMAS AVE	90028	13	148-5A185  91	5547009020	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM	ADDRESS	34.10212	-118.336	T.I. to an existing restaurant/night-club.  Change to lighting, and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50947	19041-20001-34929	9237 N WAKEFIELD AVE UNIT# 11	91402	6	198B149   619	2639008018	(T)(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.23831	-118.44831	Revisions to approved plans - change of inverter from 3.8 kW rating to 3.0 kW rating.  All other details identical.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50948	15041-10000-30573	5971 W VENICE BLVD MOB    IM-G5407	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.03865	-118.37272	ALTERATIONS IN EXISITNG OFFICE SPCE: EXPAND WAITING ROOM AND ADDING UTILITY ROOM AND ONE EXAM ROOMPLAN CHK IS FOR TITLRE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50949	15041-10000-32907	5401 W WILSHIRE BLVD	90036	4	135B181   907	5508009001	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.06244	-118.34639	Central station monitoring system.  New FACP and 4 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50950	18041-20000-43448	21800 W OXNARD ST	91367	3	177B105    81	2146006046	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.17898	-118.60253	ti to an existing commercial building.  adding new lighting new controls to exiating panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50951	16041-30001-20843	19621 W WELLS DR	91356	3	171B117   310	2164020019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.16419	-118.56108	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 18.2 kWac and consists of (3) inverters, (90) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50952	19041-20000-41391	11825 W TERRA VISTA WAY #139	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50953	15041-10001-00300	10700 S PERSHING DR	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			Reviewed by Supervisor	02/05/2015 12:00:00 AM	ADDRESS	33.93748	-118.43218	Plan check for temporary power system on construction site.Temporary Power to Job Site Trailers from existing switch board	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50954	15041-20000-08906	1999 S AVENUE OF THE STARS Ste 2040	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only. Project scope is a tenant improvement to a suite of the 20th floor of a high-rise building. Total lighting area = 2,118 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50955	14041-10000-28004	11150 W SANTA MONICA BLVD SUITE 1500	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. 8360 SQFT, EMERGENCY LIGHITNG. SUITE 1500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50956	15041-10000-32381	4050 S LINCOLN BLVD	90292	11	108B149  1389	4230002008	[Q]M1-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	33.98922	-118.44633	PC FOR POWER AND ENERGY. T.I. TO AN EXISTING RESTAURANT, NO CHANGE OF USE.  TOTAL AREA 3090 SQ FT OUTDOOR PLUS 2137 SQ FT INDOOR AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50957	19041-10000-11714	767 S ALAMEDA ST SUIT 300	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING OFFICE INA HIGHRISE BUILDING TOTAL EFFECTED AREA 23233 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50958	11041-10000-25853	10612 N NEVADA AVE	91311	12	207B101   138	2723015056	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2011 12:00:00 AM	12/30/2011 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.26284	-118.60937	Plan check 11.28KW roof mounted photovoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50959	14041-10000-27708	3052 S 10TH AVE	90018	10	120B185   748	5051035019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.02612	-118.3281	PV1 standard plan roof mounted system including (20) Enphase M215, and (20) Renesola JC250 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50960	14041-10001-25423	1406 W MANCHESTER AVE	90047	8	097-5A195 289	6037015028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	33.95984	-118.30079	Resubmittal for a non hazardous area for new installation of soil vapor, ground pump and treatment system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50961	13041-20000-15016	8445 N RESEDA BLVD	91324	12	192B125   359	2785018060	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.22408	-118.5363	PLAN CHECK FOR ENERGY AND POWER FOR LAUNDRY MAT. NEW SERVICE SIZE 800A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50962	18041-10000-27172	20060 W PRAIRIE ST 1-204	91311	12	198B113   222		(T)(Q)CM-1-MPR, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Apartment			07/24/2018 12:00:00 AM	04/22/2020 12:00:00 AM		Permit Finaled	09/03/2022 12:00:00 AM	ADDRESS	34.239	-118.57029	New 6 Story, Low Rise, 204 Units Apartment Building with 35 typical floor plans.Building Permit:L 17010-10000-01513	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50963	16041-20001-36712	7511 W ALPINE WAY	91042	7	213B197    79	2552043019	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM			PC Approved	10/24/2016 12:00:00 AM	ADDRESS	34.27748	-118.29582	Expedite per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 13.5 kWac and consists of (54) modules, (54) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50964	19041-20000-03936	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.01366	-118.28294	New fire alarm system for press box tower in LA Memorial Coliseum.  New FACP with (515) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50965	16041-20000-19905	3616 S TROUSDALE PKWY #259	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.01983	-118.28534	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR USC AHF BUILDING. SECOND FLOOR RECEPTION AND CLASSROOM # 259. 1361 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50966	16041-20000-32488	3650 S MCCLINTOCK AVE SUITE 200	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.02081	-118.28964	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES IN USC-OHE INTERIOR RENOVATION. 2ND FLOOR SUITE 200. 1497 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50967	18041-10000-48969	6730 N LAUREL CANYON BLVD	91606	2	180B165   127	2322010039	C1-1VL, P-1VL	South Valley	North Hollywood - Valley Village	NoHo		1232.04	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.193	-118.39631	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
50968	17041-20000-37149	21040 W VICTORY BLVD	91367	3	180B105    53	2149003035	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Issued	10/16/2017 12:00:00 AM	ADDRESS	34.18814	-118.59248	new fire alarm control panel with 10 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50969	19041-10000-10666	7542 N DELIA AVE STE C	91352	2	186B181   273	2405010044	QM1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1021.05	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.2079	-118.35065	Remove HID fixtures and replace with new LED fixtures (Indoor Only), - T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50970	17041-10000-43413	4200 S 4TH AVE	90008	10	114B189  1155	5023026013	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.00696	-118.32126	Pv 1, New Roof Mounted solar system using central inverters and (16) modules with DC optimizers. Total system size is 3.8kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50971	18041-10001-22588	333 S HOPE ST 34th FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Info Complete	10/23/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	Suppl Plan Check to Approved Plans for reducing Lights. <<<Plan check for Power and Energy on (E) office. TI with new loads > 400A, total area: 22,907 sq.ft. 34th floor. (B# 18016-10000-18050)>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50972	19041-20000-49649	17540 W MARGATE ST	91316	5	171B129    79	2257003025	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.16755	-118.51593	PV1. INSTALL 11.34 KW DC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50973	14041-10000-14426	3033 W WILSHIRE BLVD	90010	10	135B197  1253	5077008017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.06198	-118.28733	NEW 18-STORY MIXED-USE BUILDING (CORE AND SHELL ONLY) CONSISTING OF 190 APARTMENT UNITS (LEVEL 5-17) ON TOP OF ABOVE GRADE PARKING GARAGE (LEVEL 1-4) AND ROOFTOP SWIMMING POOL AND ASSEMBLY AREA ON LEVEL 18. THE GROUND LEVEL INCLUDES RETAILS (___S.F), LEASING OFFICE (___S.F.) AND RESIDENT AMENITIES (___ S.F.).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50974	18041-20000-35296	20700 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.29443	-118.58472	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
50975	15041-10001-44015	7417 N PONCE AVE	91307	12	186B097   638	2022007010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.20514	-118.62158	Expedited fees. (((PV1 roof mounted installation to a single family home. (1) inverter : 10 kw, (46) solar modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50976	10041-20000-21345	3607 S TROUSDALE PKWY	90089	8	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	12/28/2010 12:00:00 AM	ADDRESS	34.02013	-118.28566	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50977	18041-30000-18091	634 S MATEO ST	90021	14	124-5A217  44	5164013037	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.03694	-118.23237	New Fire Alarm system (1) FACP, (105) devices on a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50978	14041-20000-21540	5916-5918 W SANTA MONICA BLVD	90038	13	144B189   669	5534020034	C2-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.09062	-118.31838	PC FOR T24 ENERGY ONLY. REPAIR FIRE DAMAGE RETAIL TENANT SPACE. FOR UNITS 5916 AND 5918. NEW LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS. PERMIT ALREADY ISSUED UNDER 14041-30000-08213. THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50979	16041-20002-30985	18957 W CARMEL CREST DR	91356	3	162B121   162	2177048014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.14115	-118.5437	02/03/2017 Changes to an approved set of plans. System size has increased from 7.6 kWac to 10.6 kWac with the addition of (1) inverter, (2) modules, and (1) load center, for a total of (2) inverters, (34) modules, and (2) load centers. System is a battery back-up PV system.*****Previous Work Description*****PV1INSTALL ROOF MOUNTED PV SYSTEM WITH BATTERY BACK UP SIZED 7.6KW INTERCONNECTED WITH MSP.$10.37 permit fee is due to State Senate Bill SB 1222.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50980	16041-10001-42035	5250 W SANTA MONICA BLVD #304	90029	13	144B193   736	5537020029	[T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.09066	-118.30496	PC FOR PERMIT ALREADY ISSUED. MEDICAL CLINIC TI. PF FOR POWER ONLY. PER ARTICLE 517	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50981	18041-20000-36920	20059 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			PC Approved	09/27/2018 12:00:00 AM	ADDRESS	34.2756	-118.57118	Permit for the electrical scope of work for the Dolby and Prime auditoriums. Design has been done by a different engineer than the rest of the building. Plan check has been completed under application 18041-20000-21729.*****Work Description For 18041-20000-21729*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a first-time tenant to a movie theater. Total lighting area = 38,400 sq. ft.Note: Building application has been generated under 18016-20000-18638	N	N	Express Permit	06/10/2024 12:00:00 AM
50982	18041-10000-22731	424 N LAKE ST	90026	13	138A205   242	5157016023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.10	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.07133	-118.26879	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50983	16041-10000-16088	10960 W WILSHIRE BLVD 1405-1407	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR SUITES 1407 & 1405. TOTAL AFFECTED AREA IS 5073 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50984	19041-20001-53572	15237 W WEDDINGTON ST Unit 2	91411	4	172-5A145 113	2250004065	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			PC Approved	01/24/2020 12:00:00 AM	ADDRESS	34.16742	-118.46535	PV2. INSTALL 5.94 KW DC PV SYSTEM WITH (18) MODULES AND MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50985	19041-10000-52199	417-419 1/2 W 8TH ST	90014	14	127-5A209  47	5144013029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Issued	02/06/2020 12:00:00 AM	ADDRESS	34.04493	-118.25627	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE INCLUDES NEW LIGHITNG, CIRCUITS, AND CONTROLS. TOTAL AFFCTEED AREA IS 2350 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50986	18041-10000-23462	2395 N GLENDALE BLVD A	90039	13	148-5A209 432	5439006005	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.09985	-118.25949	PLAN CHECK FOR T24 ONLY, CHANGE OF USE PORTION OF (E) STORAGE ROOM AND TWO ADJACENT RETAIL SPACES TO ENLARGE EXISTING WINE SHOP/ RETAIL. (1) 100A PANEL, 1060 SQ.FT AREA, NEW LOAD < 200A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50987	19041-10000-13133	4820 S ALLA ROAD	90066	11	105B157   569	4223008010	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	33.98277	-118.42936	Plan check for a new fire alarm system located in a (2) story office building (core/shell) only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50988	16041-20000-35652	7975 W WOODROW WILSON DR	90046	4	156B173   363	5570022001	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Issued	12/16/2022 12:00:00 AM	ADDRESS	34.12302	-118.37118	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.2 KW DC . 400 AMP MAIN PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
50989	15041-20001-39158	11987 N SHOSHONE AVE	91344	12	216B129   185	2601028034	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.28919	-118.51758	PV1INSTALL ROOF MOUNTE PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(20) SOLAR WORLD SW280(20) ENPHASE MICROINVERTERS M250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50990	13041-10000-04206	15060 W GREENLEAF ST	91403	5	166-5A147 146	2276020030	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.15037	-118.46187	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. USING 2 TRANFORMERLESS INVERTERS. TOTAL SYSTEM SIZE 11.5KW. SOLAR EDGE TOTAL OF 46 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50991	17041-10000-30897	1110 E 14TH ST	90021	14	123A211   454	5132022039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.02913	-118.24861	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURE T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50992	15041-10000-04646	2801 S SAN PEDRO ST	90011	9	118-5A207 124	5128013028	CM-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.01983	-118.26264	Plan check for power and Title 24 (energy).  Total area = 4,093 sq. ft.T.I. to medical office/clinic including lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
50993	11041-10000-15094	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	INSTALLATION OF DISPLAY LIGHTING IN AN EXISTING AUDITORIUM.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50994	14041-10000-04575	724 E 10TH ST	90021	14	124-5A211 184	5132011028	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.03523	-118.25112	"PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 1542 SQFT. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50995	19041-20001-06557	687 S HOBART BLVD	90005	10	132B193   184	5093006035	(T)(Q)C2-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.0605	-118.30557	07-18-2019 Changes to an approved set of plan, changes include addtional of lighting fixtures. All changes has been clouded as delta 3 only. Plan check only, permit covered under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50996	16041-20000-18233	15260 W VENTURA BLVD 1st Floor	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Issued	06/10/2016 12:00:00 AM	ADDRESS	34.15356	-118.4658	Tenant improvement. Change of use from bank to yoga studio.   Plan check for energy.  8,468 sq ftBuilding permit filed under 16016-30000-00831.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50997	17041-20001-38120	2351 N ACHILLES DR	90046	4	153B173   795	5569007056	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.11347	-118.36716	Revisions to approved plans.  Wiring configuration changes and additon of EV charger to service subpanel. (((Plan check for AC coupled battery backup system for SFD.Existing solar system on site.(2) Tesla Powerwall 2s.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50998	19041-20000-24150	440 S SEATON ST	90013	14	127-5A215 363	5163025010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	04/28/2023 12:00:00 AM	ADDRESS	34.0421	-118.23734	new fire alarm system 59 devices and FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
50999	13041-20000-29941	9340 N ETON AVE	91311	12	198B105    71	2746010046	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.2406	-118.59517	T24 FOR EXISTING WAREHOUSE/OFFICE BUILDING. TOTAL COMBINED NEW CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT. TOTAL SQRFT 28495	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51000	18041-20000-16460	14905 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29433	-118.45531	pv1install roof mounted opv system sized 3.8kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51001	16041-10002-38230	1253 N BISHOPS ROAD CLASSROOM	90012	1	136-5A215  10	5414019007	[Q]R3-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			PC Approved	11/17/2017 12:00:00 AM	ADDRESS	34.06976	-118.23428	PC only. Changes to an approved set of plans, Note changes on delta 4. Changes include the removal of methane sensors in the Classroom BLDG garage area. _______________Installation of a new methane gas control system for private school, methane zone design level 3. (53) Control Devices, (1) Control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51002	15041-20000-23730	6416 N WYSTONE AVE	91335	3	180B121   487	2128004065	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.18725	-118.5473	Plan check for PV roof mounted system. System size: 11kW with 36 modules and 2 inverters(6.0kW and 5.0kW, Power-One)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51003	14041-20000-25939	13949 W WEDDINGTON ST	91401	4	171B153   255	2247017008	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.1668	-118.43723	MICROINVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51004	18041-10001-42449	4950 W SUNSET BLVD	90027	13	147B197   813	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.09786	-118.29745	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS UNDER DELTA #1 - CHANGES INCLUDE MODIFICATION OF FEEDER SIZES AND EGC PLAN CHECK FOR BLOOM ENERGY (300KVA) FUEL CELL SYSTEM CONNECTING TO EXISTING DISTRIBUTION EQUIPMENT - CONNECTION CONSIST OF UPGRADING 600A PANEL TO 1200A, ALL BREAKERS ARE 100% RATED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51005	19041-10000-11048	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	Energy plan check for office T.I. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51006	19041-20000-53673	3434 S GRAND AVE	90007	9	118-5A203 116	5122030020	USC-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	04/11/2022 12:00:00 AM		Issued	04/11/2022 12:00:00 AM	ADDRESS	34.01912	-118.27658	Plan check for Title 24 Energy only, retrofit existing pole lighting , site lighting(outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51007	10041-10000-06423	800 E 12TH ST #145,146 &-147	90021	9	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	05/19/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	INTERIOR REMODELLINGOF RETAIL STORE- ADDING TWO ADJACENT TENANT SPACES TO MAKE ONE TENANT SPACE NEW LIGHTING CIRCUITSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51008	17041-20002-15684	19854 W BARBERRY LANE	91356	3	162B113    98	2180021005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.13977	-118.5667	7/18/17changes to an approved set of plans.  changes include solar city standards modules #sc325 and delta salivia 7.6kw inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51009	14041-10000-03097	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	Major electrical work at the Tom Bradley Terminal North and South. Distrbuting system ( panels and circuits).  Submittal fees to be verified at time of checking plan and also for permit fees purposes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51010	14041-10000-28972	200 WORLD WAY SPACE 231	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	First time tenant - coffee kiosk within existing terminal 2 concourse.  Gate area.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51011	12041-10000-21246	635 W DOWNEY WAY	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.01874	-118.28387	NEW USC SOCIAL SCIENCES INTERDISCIPLINARY BUILDING. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51012	19041-20000-21852	13158 W WENTWORTH ST	91331	6	195B161   528	2627021032	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.23117	-118.4191	PV1.  Install 5.1 kW DC / 4.3 kW AC roof mounted grid tied PV system.  (17) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51013	13041-20000-01591	7138 N SALE AVE PV-1	91307	3	183B097   879	2024040021	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.20009	-118.61882	solar system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51014	16041-10000-26799	10743 W CUMPSTON ST	91601	2	174B177   896	2416017029	R1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	07/29/2016 12:00:00 AM	ADDRESS	34.1701	-118.36511	changes to aprove set changes include inspectors corrections to match the field(PV2. INSTALL 4.578 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER SPR-327-NE-WHT(1) INVERTER: POWER-ONE PVI-4.2-OUTD-S-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51015	14041-20000-21342	4329 N GENTRY AVE	91604	2	165B165   532	2368009024	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.14951	-118.39333	PV1Microinverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5.805kW(27) EnPhase M215-IG microinverters(27) Solar World SW255MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51016	10041-20000-20698	16255 W VENTURA BLVD	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	34.15711	-118.48768	T.I. to existing high rise building of 3rd floor.  Install and relocate general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51017	18041-20000-40506	6330 W SAN VICENTE BLVD ste 400	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.06116	-118.36804	ti to an existing commercial building (high Rise) adding new lighting new controls to existing panels.  plan check for indoor energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51018	11041-10000-26319	2727 W OLYMPIC BLVD STE 301	90006	10	129B197   189	5078008033	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.05282	-118.29315	PLAN CHECK POWER AND ENERGY FOR TI EXISTING ORTHODONTIC OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51019	16041-10000-40660	1313 W 11TH PL	90015	1	127-5A205  23	5137022017	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.04534	-118.27164	PC for energy only. Remove HID fixtures and replace with new LED fixtures. Total sqft = 38750.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51020	14041-10000-07085	5938 W 75TH ST	90045	11	102B169   342	4104012019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	33.97302	-118.38725	PV1, INSTALL  A 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(24)MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51021	15041-20000-00582	11852 1/2 N BALBOA BLVD	91344	12	216B133   474	2610002048	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.28546	-118.50127	MASSAGE PARLOR. NON MEDICAL TO BE VERIFIED BY INSPECTOR. PC FOR T24 ENERGY ONLY. NEW LIGHTING. LOW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51022	18041-20000-04593	12245 W CREWE ST	91605	2	183B165   338	2321009024	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.19672	-118.40035	Plan check for the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51023	13041-20001-23743	5720 N FULCHER AVE	91601	2	174B173   546	2337028006	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.1745	-118.3729	pv1 single family dwelling total system seize 4.2 kw ac using 20 modules transformerless inverter nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51024	17041-10001-44491	7749 N LOMA VERDE AVE	91304	3	189B109   947	2109021015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.21137	-118.58976	PC FOR REVISION TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE INCLUDES  REDUCTION IN MODULE RATING ( TO 295W),  MODULE ADDITION OF SINGLE MODULE AND  INSTALLING 5KW INVERTER ( REDUCTION FROM 6.3KW). THIS IS PLAN CHECK ONLY!permit pulled under master application(online)Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51025	17041-30000-36666	601 S FIGUEROA ST #2790	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing space office T.I. Total area: 1685 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51026	18041-20000-32205	627 S BURLINGAME AVE	90049	11	126B141    76	4264006017	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.04501	-118.48463	Plan check for a PV1 roof-mounted PV system. System size is 17.25 kWdc/15.2 kWac and consists of (2) inverters, (50) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51027	19041-10000-46608	749 S LOS ANGELES ST	90014	14	127-5A211 209	5145001900	PF-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM			PC Info Complete	02/05/2020 12:00:00 AM	ADDRESS	34.04249	-118.25175	Plan check for power only. Scope includes a new installation of 30 DC fast EV charges (18-50KW and 12-175KW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51028	14041-20000-16226	7121 N WOODLEY AVE	91406	6	183B141   198	2224009005	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Apartment			06/17/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.19983	-118.48386	New 126-unit 4-story apartment building. Plan check for Power and Energy. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51029	14041-10000-24574	4700 W WILSHIRE BLVD	90010	4	132B185    28	5090008031	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.06183	-118.3324	installation of a new fire alarm system including (261) devices and one alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51030	15041-20000-21982	6600 N TOPANGA CANYON BLVD Suite 1086	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Title 24 plan check only.  Total area = 1,825 sq. ft.  T.I. to existing retail tenant space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51031	18041-10000-36925	937 N SYCAMORE AVE	90038	4	144B181   686	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.08824	-118.34291	PC FOR POWER ONLY. SCOPE INCLUDES NEW 2000A DISTRIBUTION BOARD,  AND 800A DISTRIBUTION BOARD FOR A CORE AND SHELL WAREHOUSE BUILDING.  SERVICE IS FED FROM AN EXISTING 5,000 SERVICE IN ADJACENT BUILDING. SERVICE UNDER PCIS#16041-10000-16336 B#17016-10000-33234.  ALL LOTS ARE ON THIS BLOCK HAVE BEEN TIED TOGETHER AND RECORDED TO MAKE ONE PROPERTY WITH ONE ADDRESS: 953 SYCAMORE AVE. THRER ARE NO NEW LOAD ADDED. ALL FUTURE TI's REQUIRED COMPLETE PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51032	13041-20000-33639	12311 W ROSCOE BLVD	91352	6	192B165   452	2633001007	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.22182	-118.40147	New rooftop PV for an existing Single Family Dwelling using Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51033	10041-10000-24655	1526 N EDGEMONT ST 6th Floor	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.09898	-118.29599	TI IN AN EXISTING OFFICE AREA ON THE 6TH FLOOR (Room #'s 6019, 6022, 6023 & 6057).   Plan Check is for t-24 energy calcs and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51034	18041-10000-26339	1600 N CAMPUS ROAD ATHLETICS-BLDG.	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.12626	-118.21412	ALTERATION OF EXISTING ATHLETIC DEPT. OFFICES.  INSTALL A NEW MED. VOLTAGE TRASFORMER 4,800V:208V PLUS PANELS AND CIRCUITS. PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT# 18016-10000-21523	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51035	14041-20000-27833	9338 N SWINTON AVE	91343	12	198B137   396	2676012017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.24041	-118.48599	PV1.  Install 6.63 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51036	19041-10000-32993	11101 S LA CIENEGA BLVD	90045	11	087B173    55	4129038025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	33.93379	-118.37023	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51037	19041-10000-42874	13642 N MARCHANT AVE	91342	7	228B161   466	2580003036	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.32109	-118.4075	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 19 MODULES (LG320N1K-A5) , 19 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 6.08KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51038	14041-10004-13075	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	3/30/16: (PC only per inspector) Field revision under Delta 5A. Add inverter panel, changes on sheet GE.0.10, GE.0.20, GE.2.102/08/16Changes to an approved set of plans. All changes are made under delta 5. Scope includes adding a cut-sheet from illsco manufacturer, changing feeder tie-in using muti-tap connectors, and changing the inverter layout in the electrical room. Note: permit paid under PCIS#14041-10002-13075(((Revisions to permitted plans for new 5-stories parking structure under construction.New circcuits, panelboards, and some feeders changed from CU to AL. (((((Full Plan check for new 5 stories parking structure,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51039	18041-20000-03381	8600 N RIVENDELL CT	91306	3	192B113   737	2782011***	(Q)R1-1, (Q)RD4-1XL	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.22585	-118.57016	pv1install roof mounted pv system sized 5kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51040	16041-20000-45453	1470 S BEVERLY DR 1-39	90035	5	129B165   132	4306008025	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.05309	-118.39518	(((PV2.  Install 32 kW AC roof mounted grid tied PV system.  (132) modules with (2) 10 kW and (1) 12 kW rated central inverters.)))$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51041	16041-10001-06170	5430 N SAN FERNANDO ROAD WEST	90039	13	165B201   256	5593005050	M2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.15154	-118.275	PC Only, 200kW Co-Generator Microturbine, interconnected with the utility.<<200KW GENERATOR>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51042	13041-20000-16355	12016 W VOSE ST	91605	2	183B165   201	2321008020	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.19833	-118.395	EXISTING WAREHOUSE TO BE RECORDING STUDIO. PLAN CHECK FOR T24 ENERGY ONLY. TOTAL AREA 4849 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51043	11041-10001-02334	1930 W WILSHIRE BLVD	90057	1	132A203    41	5142002019	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	08/08/2011 12:00:00 AM	ADDRESS	34.05713	-118.27464	INSTALLATION OF LUMINAIRES  UNDER NON-SALES CANOPY AND LUMINAIRES TO ILLUMINATE A WALKWAY AREAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51044	19041-10000-38593	333 N MARINE AVE	90744	15	030B205  1348	7418022008	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	33.77374	-118.26343	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51045	14041-20000-01884	4012 N SUMAC DR	91403	4	162B149   191	2275006024	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.14293	-118.44937	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51046	14041-20001-23952	13691 N GAVINA AVE #604	91342	7	225B165     2	2580017007	(T)(Q)RD6-1, (T)(Q)RD6-1-K, A1-1-K, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	34.31924	-118.40195	FEE CHARGE $0.00 BY STATE SENATE BILL NO. 1222.REVISIONS TO AN APPROVED SET OF PLANS. REMOVING 10 SUNMODULES SW-250 AND LOAD CENTER.PV1Microinverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5.59kW.(26) EnPhase M215 microinverters(26) SolarWorld SW250W POLY pv modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51047	19041-10000-09279	2756 W JAMES M. WOOD BLVD	90006	1	132B197   806	5077028011	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			03/14/2019 12:00:00 AM	03/20/2019 12:00:00 AM		Issued	03/20/2019 12:00:00 AM	ADDRESS	34.05572	-118.28821	REPLACING 28 EXISTING SMOKE DETECTORS WITH NEW SD/CO IN AN EXISTING 14 UNIT APARTMENT BULDING, PART OF THE FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51048	19041-10000-44499	10270 N BROOKE AVE	91311	12	204B101   178	2745001016	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.25691	-118.60751	PC FOR NEW ROOF TOP SOLAR 3.48 KWdc (3.80 KWac) using 12 REC290WTP2 MODULES, 12 SOLAREDGE P320 OPTIMIZERS AND 1 SOLAREDGE SE3800H-US CENTRAL INVERTER.CONNECTED TO AN EXISTING 100Amp SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51049	16041-30001-20841	11661 N GLADSTONE AVE	91342	7	213B165   270	2531022017	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.28202	-118.39754	Expedited per applicant request.Plan check for the addition of a PV1 system onto an existing PV1 roof-mounted PV system. Addition system size is 3 kWac for a total system size of 10.6 kWac. System addition consists of (1) inverter and (7) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51050	17041-10000-19832	4850 N NOMAD DR	91364	3	168B113   101	2175017009	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.15936	-118.5676	PC for two new Tesla Powerwall2 units connecting to backup subpanel and existing solar system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51051	17041-10000-03978	900 N ALAMEDA ST 4th floor	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	T-24, PC for energy only. Interior T.I. on the 4th floor Office Building. Scope includes new panels, new lights, and receptacles for a corridor space on the 4th floor. Total affected area is 8909 Sq. Ft. b#16016-10000-29338	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51052	14041-10001-23574	5539 N RIVERTON AVE	91601	2	174B173  1109	2416014026	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	34.17108	-118.36581	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. GROUNDED CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 100KW DC.(400) ECOSOLARGY 250 WATT MODULES(3) POWER ONE ABB 20KW INVERTERS.(1) POWER ONE ABB 27KW INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51053	15041-10000-18593	614 E TERMINAL WAY Transload-Bldg	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	33.74201	-118.26431	New fire warning system for Transload Building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51054	16041-20001-32461	247 N AMALFI DR	90402	11	123B129   701	4410022026	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM			PC Approved	10/05/2016 12:00:00 AM	ADDRESS	34.03164	-118.51386	EXPEDITE PER APPLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.7KW INTERCONNCTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51055	17041-10000-06023	419 S SPRING ST	90013	14	129A211    54	5149024027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM			PC Info Complete	07/07/2017 12:00:00 AM	ADDRESS	34.04843	-118.24885	FULL PC FOR POWER AND ENERGY.    CHANGE  OF  USE FROM  OFFICE  TO  HOTEL 14 STORY, 180 UNITS  IN A   HIGH RISE BUILDING,  FIRST FLOOR RESTAURANT CORE AND SHELL ONLY.  SCOPE INCLUDES TWO NEW 1200A 480/277 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARDS, NEW PANELS, AND NEW CIRCUITS.  TOTAL AFFECTED AREA IS 85,583 SQ FT.    B#13016-10000-26325	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51056	10041-10000-08034	423 W 8TH ST	90014	14	127-5A209  42	5144013028	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM			PC Info Complete	05/20/2010 12:00:00 AM	ADDRESS	34.04498	-118.25634	upgrading 7 story existing hotel with 3 existing service. 5 less than 200 amps panels and one 400 amps. 145 new ckt and 1 45kva xfmr. plan check for power .PERMITS WERE OBTAINE ON APPLICATIONS 10041-10000-00920; 10041-10001-00918;10041-10002-00918;10041-10003-00918;10041-10000-00919	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51057	13041-20001-30751	6333 W 3RD ST Stall 126	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.07157	-118.36014	((CHANGES MADE TO APPROVED SET OF PLANS. MADE REVISIONS TO THE SINGLE LINE))Outdoor Farmers Market. Change to lighting and electrical.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51058	18041-20000-43255	888 S FIGUEROA ST Ste 1050	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI to an existing commercial building (medical office).  Adding new lighting new controls to new  panels.  Newly connected load < 400 amps - plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51059	12041-10000-06162	12045-12049 W OSBORNE ST	91331	7	210B165   543	2532017066	(T)(Q)C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.06	Electrical	Electrical	Apartment			03/22/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	34.27283	-118.39518	PLAN CHECK  2 STORY APARTMENT BUILDING. BLDG #3 AND #4 ARE CONNECTED BY A ROOF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51060	18041-20000-18794	3115 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.02984	-118.37443	Tenant improvement to (E) manufacturing building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51061	18041-20002-07137	12106 N BELLANDO CT	91344	12	219B125    88	2601073017	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.29366	-118.52559	Plan check for Load calculation per inspector requestFees $0 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51062	16041-10000-33168	4420 S MENLO AVE	90037	9	111B197   225	5018005006	RD3-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	10/29/2016 12:00:00 AM	ADDRESS	34.003	-118.28953	PC FOR PV. SYSTEM SIZE 3.0KWAC  SYSTEM INCLUDES  (11) MODULES 265W KYOCERA # KU2656ZPA.  (1) PVI-3.0-OUTD-US**Note to inspector:There is an existing underground conduit from 125A panel at 4420 S. Menlo that connects to the 200A main service panel  located on 4421 S. Orchard Ave. Both addresses are on the same parcel and owner.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51063	17041-10000-10201	435 S CURSON AVE WEST GARAGE # 1	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.06738	-118.35657	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 24775 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51064	18041-10000-00297	10250 W SANTA MONICA BLVD #1150	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC for T24 only for retail TI ""samsonite (existing space with no change of use). Installing new lights and receptacles. Power connects to existing service in the building."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51065	13041-10000-35178	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Closed	01/31/2014 12:00:00 AM	ADDRESS	34.06209	-118.34912	TEMPORARY CONSTRUCTION SERVICE AND ASSOCIATED EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51066	15041-10000-26236	1348 N MARINETTE ROAD	90272	11	132B129    67	4422032016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM			Reviewed by Supervisor	09/18/2015 12:00:00 AM	ADDRESS	34.05461	-118.51963	PV1INSTALL GROUND MOUNT PV SYSTEM SIZED 22.8KW INTERCONNECTED WITH MSP.(74) MODULES(2) 11.4KW INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51067	11041-10000-21669	1440 N VINE ST	90028	13	147A189   104	5546023050	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.09695	-118.32648	TENANT IMPROVEMENT TO (E) RETAIL/SERVICE USE:  (N) INTERIOR NON-BEARING WALLS, CEILINGS SYSTEMS, MILLWORK AND FINISHES TO CREATE ACCESSORY ROOMS AND OFFICE.  INCLUDES REPLACEMENT OF RETAIL FIXTURES.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51068	16041-10000-15319	3740 S GRAMERCY PL	90018	8	117B189   228	5042015004	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.01979	-118.3137	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.84KWac.(12)MODULES-SUNPOWER SPR-327NE-WHT-D(1)INVERTER-SMA AMERICA SB3800TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51069	18041-10000-31390	1542 N TOWER GROVE DR	90210	5	147B157   255	4356019021	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	04/12/2022 12:00:00 AM	ADDRESS	34.09821	-118.42574	Install Ground mounted PV system with ESS. Install: (98) modules;   (2) 14.4 kW AC central inverters,  and (1) 7.6 kW AC central inverter that connects to (2) ESS, which  are connected to the Emergency Back-up Panel and routed through (E) ATS and (E) generator; (2) New 100A subpanel, (1) 10 kVA transformerPERMIT FEE IS $ 0 DUE TO ASSEMBLY BILL 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51070	19041-10000-48794	13420 W VENTURA BLVD	91423	4	165B157   832	2373005007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	05/11/2021 12:00:00 AM		Permit Finaled	05/10/2023 12:00:00 AM	ADDRESS	34.14692	-118.42559	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A CHANGE OF USE, SCOE OF WORK INCLUDES NEW LIGHITNG, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 1110 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51071	15041-20000-02661	12500 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/31/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51072	13041-10002-34431	1243 S OLIVE ST	90015	14	126A207   200	5139023900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/06/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.03859	-118.26331	(9/28/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGING FEEDERS FROM COPPER TO ALUMINUM. REVISED ENERGY CALCS AND LIGHTING FIXTURES TO EXISTING AREAS.  NEWLY ADDED LOAD < 400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.  CHANGES NOTED UNDER DELTA 27.  NARRATIVE LETTER PROVIDED WITH SUBMITTAL.   POWER AND ENERGY PLAN CHECK FOR for New 7 Story (5 Story Type III-A over 2 Story Type IA Podium) Mixed Use Building w/293 Unit Apartment & Retail Building. Located in methane zone.ASSOCIATED BUILDING PERMIT: 13010-10001-02722	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51073	15041-10000-07448	4708 W OAKWOOD AVE	90004	4	138B193   299	5522032013	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.07708	-118.30963	NEW FIRE ALARM SYSTEM 107 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51074	15041-20000-33054	801 S GRAND AVE Suite 600	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.04581	-118.25842	Plan check for Title 24 only. Project site is the 6th floor of an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 17,816 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51075	17041-20000-12613	3070 S EARLMAR DR	90064	5	123B165   159	4316015023	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.03636	-118.40468	PV1.  Install 9.6 kW roof mounted grid tied PV system.  AC module standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51076	14041-20000-04353	821 N STRADELLA ROAD	90077	5	141B149   114	4369023011	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.08375	-118.45353	Roof mounted PV system (6.48KW) with microinverters.Note: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51077	18041-20000-24002	3571 S COLONIAL AVE	90066	11	114B153   798	4246010012	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	07/21/2018 12:00:00 AM	ADDRESS	34.00809	-118.43855	Plan check for PV roof mounted system with battery back up, system size: 8.55kWac, 10.2kWdc, 29 modules LG350W1C-A5 MONO  and 29 microinverters Enphase IQ7PLUS-72-X-US 240V. , battery back up Tesla Powerwall AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51078	14041-20000-33262	7900 N SEPULVEDA BLVD	91405	6	189B145   465	2209032042	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.21386	-118.46596	Convert the existing manufacturing/auto part sales building to retail.  Add new subpanels and lighting with connected load exceed 400A.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51079	15041-20001-08299	17323 W SATICOY ST	91325	12	186B133   178	2202009008	C2-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Expired	06/02/2017 12:00:00 AM	ADDRESS	34.20855	-118.51074	Plan check for Humble Bee Restaurant Title 24 only. Total area: 1040 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51080	11041-10000-18238	861 W ROSECRANS AVE	90247	15	075B197   224	6119015009	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	33.90206	-118.29103	TI TO AN EXISTING 7-ELEVEN.  REPLACEMENT OF EXISTING LIGHT FIXTURES WITH LED FIXTURES.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51081	13041-10001-27874	12832 W INDIANAPOLIS ST	90066	11	114B149   313	4247012009	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.01033	-118.4486	][][]EXPEDITED PER APPLICANT REQUEST ][][]PV1, 2.16KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(9)modules: {Trina {TSM-240PA05}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}] . NEW 125A LOAD CENTER IS ADDED. THIS PV INSTALLATION IS IN ADDITION TO AN EXISTING 1 STRING OF 10 MODULES, (1) SUNNY BOY SB3000US PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51082	13041-10000-27204	3155 W SAN FERNANDO ROAD	90065	13	154-5A213 187	5458007009	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.11612	-118.2469	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALL NEW FLUORESCENT FIXTURES. 2200 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51083	19041-10000-40996	737 S LAMAR ST	90031	14	135A219   168	5410013011	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	10/24/2020 12:00:00 AM	ADDRESS	34.06375	-118.22383	This appliaction covers all the permit fees for the two systems, the supplemental permit under 19041-10002-40996 is for the second system. 0$ final fees per AB1414plan check for PV-2 system system has two components:1-system (1):(602)Hyundai HIA-S375HI modules, 225.8KW DC(2)SMA PV1 62-US-41 62KW inverters(1)SMA PV1 50-US-41 50KW inverters174KW AC total2-system (2):(238)Hyundai HIA-S375HI modules, 65.8KW DC(2)SMA PV1 33-US-41 62KW inverters66KW AC total(1)75kva	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51084	15041-10000-33954	10982 S GRAPE ST	90059	15	088-5A215 458	6067008081	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	33.93529	-118.23682	PV1, ROOF MOUNTED SOLAR SYSTEM. (28) MODULES AND (1) INVERTER. (28) KYOCERA #KU2656ZPA(1) PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51085	13041-20000-33836	6935 N AMESTOY AVE	91406	6	183B133   656	2230003022	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Expired	02/02/2016 12:00:00 AM	ADDRESS	34.19682	-118.50566	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8 KW AC USING 42 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51086	13041-10001-29599	3911 W FERNWOOD AVE	90027	4	147A203   334	5430026015	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.09646	-118.27766	Expedited RSES plan check per applicant request. ((((PV1.  Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3000A-US.  10 modules: Trina Solar TSM-250PA05.18.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51087	17041-10000-02854	160 N GLENDALE BLVD	90026	1	135A209   280	5160013011	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	05/19/2022 12:00:00 AM	ADDRESS	34.06352	-118.25967	Plan check for power and energy for office T.I. install equipment rated at 600A.  Total area: 17,075 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51088	17041-20000-02869	1520 W JAMES M. WOOD BLVD System B	90015	1	130-5A205 328	5137004029	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Issued	03/24/2017 12:00:00 AM	ADDRESS	34.05009	-118.27201	pv2install roof mounted pv system sized 3kw interconnected with msp.This is system B	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51089	14041-20000-25368	11812 W SAN VICENTE BLVD suite 125	90049	11	129B145   113	4265018016	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.0528	-118.4684	Plan check for energy only. TI for an existing office in suite 125 of existing low-rise office building. New receptacles and lighting (incl. emergency). 2,088sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51090	10041-10000-25423	8370 W 3RD ST	90048	5	138B173   843	5511031022	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	01/05/2011 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.07279	-118.3724	REMODEL EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24. PERMIT FOR NEW CKTS AND MISC. WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51091	13041-20000-11049	19761 W BAHAMA ST	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.23351	-118.56404	TI TO EXISTING WAREHOUSE. CHANGE IN LIGHTING FIXTURES FOR MORE ENERGY EFFICIENT TYPE. CHANGE IN CONTROLS. PC FOR T24 ENERGY ONLY. TOTAL AREA 8320 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51092	14041-20000-00308	8220 N VAN NUYS BLVD	91402	6	192B149   505	2212004033	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.22039	-118.44858	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING RESTAURANT. TOTAL SQRFT 9011	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51093	19041-20000-08605	12321 N FINCH ST	90039	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	PIN	34.3012906	-118.58563914	PV1.  Install 5.03 kW roof mounted grid tied PV system.  (15) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51094	14041-20000-04866	9175 N DE SOTO AVE	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.23782	-118.58874	PC FOR NEW FIRE ALARM SYSTEM WITH 10 DEVICES. 2 PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51095	19041-20000-02941	9077 N VAN NUYS BLVD	91402	6	198B149   581	2651010064	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	PIN	34.23515162	-118.45068506	T24 PLAN CHECK FOR LIGHTS AND OUTLETS, TOTAL SQFT'G = 1151	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51096	18041-10000-01226	1517 S MATEO ST	90021	14	121-5A217 284	5167001057	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Issued	01/12/2018 12:00:00 AM	ADDRESS	34.02671	-118.23238	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51097	12041-20000-30993	7626-7630 N VINELAND AVE	91352	2	186B173   209	2409016022	(T)(Q)C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.20897	-118.37008	"(N) 57'4"" X 190'4"" 2 STORY TYPE VB SPRINKLERED BUILDING WITH RETAIL ON 1ST FLOOR AND OFFICE ON 2ND FLOOR.  Plan checker to require T24 interior and exterior certificates and worksheets, and charge fees."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51098	12041-10000-00284	4610 S HOOPER AVE	90011	9	112-5A211 250	5107011013	RD2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10, 2287.20	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.00182	-118.25199	PLAN CHECK POWER AND ENERGY FOR 2-STORY ADDITION FOR EXISTING CHURCH. NEW 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51099	11041-10000-04195	640 S MAIN ST	90014	9	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	05/19/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.04429	-118.2507	NEW RESTAURANT IN HOTEL 1ST FLOOR, IN A 15-STORY BUILDING.  FULL PLAN CHECK W/ T-24.  FIRE ALARM WILL BE ON A SEPERATE APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51100	11041-10000-18042	1318 E OLYMPIC BLVD	90021	14	123A213   140	5130001041	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	34.03147	-118.24372	TI TO AN EXISTING COMMERCIAL COLD STORAGE FACILITY.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51101	19041-10000-21474	13255 W PONDEROSA DR	90049	11	138B133    47	4492007018	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	01/08/2021 12:00:00 AM	ADDRESS	34.07795	-118.50355	PV1. NEW ROOFTOP SOLAR SYSTEM WITH ENERGY STORAGE. SYSTEM CONSIST OF 18 AC MODULES (SUNPOWER SPR 360) AND 2 TESLA POWERWALL BATTERIES (27 KWH). SCOPE INCLUDES NEW 125A COMBINER BOX AND 125A LOAD CENTER. SYSTEM SIZE IS 5.67KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51102	17041-10000-17429	1318 E 7TH ST 154	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.03608	-118.24052	Title 24 plan check.  T.I. to existing restaurant space.  3 new subpanels and one new 45 kVA transformer to feed new lighting and receptacles.  Total area = 2,210 sq. ft.       Building permit #17016-10000-09323	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51103	19041-20000-50857	11049 W BLIX ST	91602	4	168B173   561	2353026019	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Issued	12/10/2019 12:00:00 AM	ADDRESS	34.1567	-118.37224	Plan check for PV roof mounted system, PV system size: 10.00KW with 25 AC Modules and 1 sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51104	10041-10002-17850	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM			PC Approved	06/07/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	MODIFICATION TO AN APPROVED SET OF PLANS.  MODIFICATION IS FOR T-24.  ADDITION OF 2 ADDITIONAL LIGHTS FOR THE WALK WAY.  T-24 PLAN CHECK ONLY <<<<<New canopy and addition of passenger loading area. Plan check for T24.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51105	14041-10000-17567	8500 W BEVERLY BLVD # 707	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	tenant improvement in retail store Club Monacoplan chk is for title 24 ane 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51106	13041-20000-22456	12616 W VENTURA BLVD	91604	2	162B161   123	2384022027	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	34.14365	-118.40828	T24 FOR EXISTING GROCERY STORE. TOTAL SQRFT 2283	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51107	16041-20001-44593	7324 N OWENSMOUTH AVE	91303	3	186B105   769	2111014008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.20358	-118.60141	PV1.  Install 3.5 kW roof mounted, grid tied PV system on SFD main house and detached garage.  (11) modules with Enphase M250 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51108	13041-20000-01629	6372 W SUNSET BLVD	90028	13	147A187   590	5546015043	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.09768	-118.32836	New  30KVA transformer, new panel, circuits, lighting to an existing restaurant space.  Place of Assembly, Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51109	19041-10000-44049	4139 N RHODES AVE	91604	2	165B165  1061	2367010034	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.14608	-118.40315	NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 12.48 KW DC/ 10KW AC, WITH A SOLAR EDGE CENTRAL INVERTER (SE10000H-US), 39 MODULES (LG320N1K), 39 SOALREDGE P320 OPTIMIZERS CONNECTED TO A NEW 225A SERVICE .NOTE: NEW SERVICE UNDER AN EXPRESS PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51110	13041-10000-35575	1001 S OLIVE ST	90015	14	127-5A209 272	5139010009	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.04228	-118.25988	PLAN CHECK FOR POWER AND ENERGY. NEW 7 STORY APARTMENT OVER RETAIL AND PARKING MIXED USE BUILDING. (2)  4000 AMP SERVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51111	15041-10000-39962	555 W 5TH ST 36TH FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.05016	-118.25369	PLANCHECK FOR POWER AND ENERGY FOR OFFICE ON THE 36TH FLOOR. NEW CONNECTED LOAD EXCEEDS 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51112	13041-20000-35337	7316 N BELLAIRE AVE	91605	2	186B161   535	2324002017	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.20428	-118.40929	T24 FOR EXISTING SHOWROOM FOR RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51113	17041-10000-13884	111 S LUCAS AVE	90026	13	133-5A209 113	5153030021	CW	Central	Westlake	Westlake North	YES	2083.02	Electrical	Electrical	Apartment			04/27/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.06147	-118.25986	NEW FIRE ALARM SYSTEM FOR A NEW  6-STORY BUILDING WITH 467 FA DEVICES AND 3 FIRE ALARM PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51114	16041-10000-32266	9613 N GOTHIC AVE	91343	12	201B137   825	2677011014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Issued	09/12/2016 12:00:00 AM	ADDRESS	34.24497	-118.49106	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(11)MODULES-SUNEDISON SEF270KZD3Y(11)OPTIMIERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51115	18041-10001-20368	461 W 41ST ST	90037	9	115-5A201 236	5019026018	C2-1L	South Los Angeles	Southeast Los Angeles	Voices		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM			PC Approved	07/11/2018 12:00:00 AM	ADDRESS	34.00934	-118.28199	DELTA 1 CHANGES TO APPROVED PLANS FOR RELOCATING 3 PANELS. PLAN CHECK ONLY<<<INSTALL A NEW 4.68 KW DC WITH 13 AC MODULES PV SYSTEM ON A SINGLE FAMILY HOME.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51116	14041-10000-32866	3201 S HOOVER ST Building 8	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Apartment			11/26/2014 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	Plan check for power and title 24.  Total common area for title 24 calculation = 165,064 sq. ft. (conditioned) and 6,436 sq. ft. (unconditioned).  New 5 story 103 unit dorm at The Village USC.  7 typical units with 1,378 residential branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51117	16041-10000-03786	3500 W WILSHIRE BLVD UNIT #201	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Info Complete	02/02/2016 12:00:00 AM	ADDRESS	34.06157	-118.30077	TI ON EXISTING FOOD FACILITY #201, INSTALL NEW LIGHTS ON THE BAR AREA 231 SQ.FT. PC FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51118	10041-10000-03827	7100 N WHITAKER AVE Bld. B	91406	6	183B137   525	2225011001	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	05/18/2010 12:00:00 AM	ADDRESS	34.19961	-118.49768	"New building ""B"" with 960 s.f.  Install new panel, branch circuitsm, and lighting.  Plan check for power and energy. The building ""B"" is part of the same structure as building ""A"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51119	16041-10000-39901	11145 N TAMPA AVE	91326	12	210B117    35	2701004014	(Q)C2-1, C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.27342	-118.55727	PC FOR T24 ONLY. REMOVE E HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA (OUTDOOR) 134003 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51120	15041-20000-33022	640 N LA BREA AVE	90036	4	141B181   665	5525017019	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.08306	-118.34386	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement; change of use from retail to gym. Total lighting area = 2,980 sq. ft.Note: Building permit has been issued under 15016-20000-13212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51121	19041-20000-20697	124 N FLORES ST	90048	5	138B173   708	5511017005	[Q]R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.07513	-118.37093	Plan check for a PV2 roof-mounted PV system. System size is 4.95 kWdc/4.6 kWac and consists of (1) inverter and (15) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51122	10041-10000-21396	10341 N WOODLEY AVE	91344	12	204B137   113	2679007039	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.25922	-118.48504	Upgrade service to 600A. this service willbe supplying power to three existing building/structure and a new building for a celluar site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51123	15041-10000-14009	939 S BROADWAY	90015	14	127-5A209 278	5139003006	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.04157	-118.25708	install new fire alarm system with 661 fa devics and 1 fa panel and two power supply.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51124	13041-10000-18514	10700 W SANTA MONICA BLVD 140	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/12/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.05167	-118.432	MEDICAL FACILITY DENTAL OFFICE SUITE 140. TITLE 24 ENERGY AND POWER PLAN CHECK AND PERMIT. CORE AND SHELL DONE UNDER SEPERATE APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51125	14041-20003-02818	15935 W GRESHAM ST	91343	12	195B141   407	2672024014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.23116	-118.47966	Changes to approved set.  Additional AC disconnect provided at front of house.  $0 submittal fee is due to Senate Bill SB-1222.  (((changes to approved set of plans. changes clouded delta 1)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51126	17041-10001-38950	1128 N HYATT AVE	90744	15	033B209   538	7423027058	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			Reviewed by Supervisor	11/07/2017 12:00:00 AM	ADDRESS	33.78589	-118.25403	*Fee expedited per applicantInstall new 5kW AC rooftop solar system, and 13.5 kWh ESS on a SFD.(20) modules with (20) optomizers, (1) inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51127	14041-20000-26959	6100 N FIGUEROA ST	90042	14	153A231   348	5492026027	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.11212	-118.18766	PV2: Install a roof-mounted solar array on roof of commercial office building, inteconnect at DWP transformer vault. System size: 37kW.  (3) ABB PVI-10.0-I-OUTD high frequency trasformered inverters(136) SunModule SW270 MONO pv modules.Note: Permit fee is $00.00 due to 2012 State Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51128	15041-10000-11036	336 W 31ST ST	90007	9	120A203   161	5122019024	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.0229	-118.27605	T24 only. Remove hid fixtures and replace with new LED fixtures. Total area 50076 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51129	13041-20000-22522	1011 S FIGUEROA ST 2ND FLOOR	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.04476	-118.26452	T24 FOR EXISTING HIGHRISE OFFICE SPACE. TOTAL NEW CONNECTED LOAD LESS THAN 400A PER APPLICANT. TOTAL SQRFT 7806. SCOPE OF WORK ON THE SECOND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51130	17041-20001-35358	2209 S SANTA FE AVE	90058	14	118-5A217 206	5167008028	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM			PC Approved	10/25/2017 12:00:00 AM	ADDRESS	34.01795	-118.23056	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 115 KW (320) NEO SOLAR POWER 360(3) SOLAR EDGE SE33.3KUS(160) P800 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51131	17041-10000-14235	1285 E VERNON AVE	90011	9	112-5A211  36	5115035028	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Info Complete	05/03/2017 12:00:00 AM	ADDRESS	34.00407	-118.2523	Title 24 plan check.  Addition of new 200 amp panel and lighting to car wash tunnel.  Total area = 821 sq. ft.     Building permit #15016-10000-04900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51132	19041-20000-16709	1617 N LUCRETIA AVE	90026	13	141A209    14	5419007012	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.20	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.08259	-118.25564	addition of (1) tesla battery ESS 5KW AC to an existing pv system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51133	12041-10001-28348	2231 S BARRINGTON AVE	90064	11	123B149   480	4260012027	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.03337	-118.44727	"SUPPL. APPLICATION FOR CHANGES TO THE APPROVED PLANS. REDUCED LIGHTS FOR THIS CORE & SHELL PORTION OF PROJECT. COMPLETE ELECTRICAL PLAN CHECK IS REQUIRED FOR THE ""TI"".  PERMIT WAS ISSUED UNDER PCIS # 12041-10000-28348"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51134	13041-20000-06388	11315 S FIGUEROA ST	90044	8	087A201   235	6075026029	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	PIN	33.93143118	-118.28297189	Change of use from Retail to Restaurat.  Not a first-time-tenant.  Load is less than 400 amps and occupancy laod is less than 99 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51135	19041-10000-38596	4810 N WHITSETT AVE	91607	2	168B165   458	2356032001	C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.15791	-118.40505	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51136	16041-10001-42206	838 W 30TH ST	90731	15	009B197  1349	7469010009	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			PC Approved	01/13/2017 12:00:00 AM	ADDRESS	33.71751	-118.29665	Expedited fees. PV2 roof mounted solar system installation to a commercial site. Intalling a 3.0 kw central inverter with 18 solar modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51137	14041-10000-05142	16860 W CHARMEL LANE	90272	11	135B117   127	4420035025	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.06338	-118.55188	New roof mounted PV system for sfd. 6.2kw system using M215 micro inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51138	17041-20001-08371	11755 W WILSHIRE BLVD ste 1250	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Approved	03/20/2017 12:00:00 AM	PIN	34.04869377	-118.46238681	03/20/2017 Changes to an approved set of plans. There has been an addition of a new panel board and branch circuits.*****Previous Work Description*****Plan check for energy only. TI to existing office suite 1250 on 12th floor of high rise office building. New lighting. 9,540sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51139	12041-20000-10569	6080 W CENTER DR 900	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	33.97713	-118.39172	T.I. to existing high rise building on 9th floor.  Install general/emergency lighting.  Plan chck for energy only.Note: Permit issued under 12041-90000-09627	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51140	13041-10003-29911	960 E 3RD ST	90013	14	127-5A217  90	5163016011	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.04578	-118.23289	"Changes to approved set.  Revisions to match field installation.  Note to permit issuing staff: fees for permit can be found under ""Inspection.""  No ""Final"" fees calculated.  (((Full plan check. Two story additon and interior renovation to an existing, two story professional school.  FA variance is filed,  Paint booth are listed by recognized testing laboratory. cra clearnce obtained under building permit 13014-10000-04395)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51141	16041-20000-07995	1743 S WESTWOOD BLVD	90024	5	129B153   343	4324028047	C4-1VL-O-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.0511	-118.43846	Plan check for power and energy. CHANGE OF USE FROM BEAUTY SALON TO DENTAL CLINIC: TENANT IMPROVEMENT. Subject to Article 517. 1,265 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51142	13041-10001-16314	401 WORLD WAY	90045	11	090B161    37	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	33.94281	-118.40686	][][] supplemental to existing work under 13041-10000-16314 (not yet approved) . supplemental is to account for the addition of lighting work in parking garage elevator and lighting upgrade. total projected area in new scope of work is 397632 sq ft of illuminated area. Since the area is > 30,000 sq ft it could not be charged under submittal-2 fee under the original 10000-series application, which was marked over the counter. ][][][permit to be pulled under original permit. Plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51143	10041-10001-15136	1521 W FRANCISCO ST Bldg A	90501	15	057B193    25	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM			PC Approved	10/14/2011 12:00:00 AM	ADDRESS	33.8496	-118.30518	New building.  New service, panels, and branch circuits.  Plan check for energy and power.NOTE: refer to 10041-10K-15139 for  Bldg B 99((((((((((((((((((((   title 24 changed by addition of 5 lights.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51144	13041-10000-09563	18021 W HATTON ST	91335	3	186B125    22	2120013002	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.21008	-118.52596	INSTALL ROOF- MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 5.88 kW. INVERTERS: SUNNY BOY 6000-US. TSM-245, 24 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51145	16041-10006-16336	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			PC Approved	04/05/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 17 ONLY ADDING POWER TO FC AND CONDENSOR.<<<<FULL PC FOR POWER AND ENERGY. NEW 4000A 277/480 3 PHASE 4 WIRE SERVICE FOR A NEW 8-Story Media Production Office Building (core and shell). TOTAL AFFECTED AREA IS 154499 SQ. FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51146	18041-20000-44134	7134 N SEPULVEDA BLVD	91405	6	183B145    83	2220022***	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.20015	-118.46599	Lights and dedicated circuits for remodel of bakery area in market.  Plan check for Title 24 Part 6 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51147	16041-10000-19585	19535 W MERRIDY ST	91324	12	204B117   489	2726014008	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.25285	-118.55925	PV1 STANDARD PLAN SINGLE FAMILY WITH MICRO INVERTERS TOTAL RATING @ 5.23KW.16 MODULES WITH INTEGRATED MICRO INVERTERS (SUN POWER E20-327-C-AC).  INCLUDING A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51148	10041-10000-01630	1831 S PACIFIC AVE	90731	15	012B197   920	7462007015	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro		2972.00	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	33.72718	-118.28825	New 7-11 Store - Permit is for new service, distribution, panels, equipment, ckts, and lighting.  P/C is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51149	12041-20000-01836	5311 S RUTHELEN ST	90062	8	108B193   440	5005020011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Apartment			01/25/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	33.99384	-118.31272	upgrade 20 units apartments	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51150	19041-20000-01173	1950 S SAWTELLE BLVD	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	05/26/2022 12:00:00 AM	ADDRESS	34.04129	-118.44377	ti to an existing commercial building, restroom and corridors. adding new lighting new controls to  existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51151	18041-10000-33324	19260 W NORDHOFF ST	91324	12	198B117   233	2784001023	(T)(Q)C2-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	11/07/2022 12:00:00 AM	ADDRESS	34.23522	-118.55294	Energy plan check for a NEW carwash addition to an existing gas stattion. Scope include new lighting and equipment with a total area of 995-SQ FT.  Scope is not part of the hazardous area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51152	16041-30000-15427	801 S FIGUEROA ST 1700	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is a portion of the 17th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 7,915 sq. ft.Note: Building application has been created under 16016-10000-09175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51153	19041-20000-35595	916 N ALVARADO ST #1-27	90026	13	139-5A207 253	5404004013	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1957.20	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	04/20/2021 12:00:00 AM		Permit Finaled	09/27/2022 12:00:00 AM	ADDRESS	34.0758	-118.26438	Install (N) 1200amps 208/120V 3 phase 4w service. Install new distribution boards, panels, equipments and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51154	15041-10000-06585	11975 W BLUFF CREEK DR	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	33.98224	-118.40247	PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING only.  NEW PARKING STRUCTURE (2 STORIES).  TOTAL SQUARE FOOTAGE 96472.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51155	15041-20000-05213	15910 W VENTURA BLVD 9th floor-restroom	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.15561	-118.47969	Plan check for Title 24 only. Project is a TI to a bathroom on the 9th floor of a high-rise building. Total lighting area = 351 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51156	12041-20000-17219	21700 W OXNARD ST #1900	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.17901	-118.60179	T.I. to high rise building of existing office space on 19th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51157	19041-20001-03805	15846 W NAPA ST	91343	12	192B141   100	2673009035	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM			PC Approved	07/10/2019 12:00:00 AM	ADDRESS	34.22642	-118.47802	07/10/2019 Changes to an approved set of plans. All changes have been clouded. PV module model has changed and an AC disconnect has been removed.*****Original Work Description*****Plan check for PV roof mounted system, system size: 9.1KW, 10.4KW AC with 28 PV Modules and 2 inverter(5.2KW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51158	11041-10000-02894	2222 S LA BREA AVE	90016	10	123B181   152	5062018028	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM			PC Approved	02/23/2011 12:00:00 AM	ADDRESS	34.03682	-118.34889	T-24 ONLY PER INSPECTOR'S REQUEST PER THE APPLICANT.   EXISTING OFFICE BUILDING NEW LIGHTING FIXTURES, SINGLE STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51159	13041-20000-33950	3524 E LAVELL DR	90065	1	151-5A217 175	5462006020	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.11015	-118.22973	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC. 12 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51160	18041-10000-37667	1533 N SCHRADER BLVD Admin Bldg	90028	13	147A187    32	5547018901	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	34.09901	-118.33257	New emergency temporary shelter for the homeless consisting of two separate state certified modular buildings-Admin Bldg; Hygiene Bldg  and new constructed building- Membrane Bldg-.The branch circuits inside the Admin Bldg and Hygiene Bldg will be part of the state certificationThis application is for the service equipment and the administration building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51161	18041-20001-30165	24208 S STERLING RANCH ROAD	91304	12	192B089   197	2017039008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.21939	-118.65432	change of address	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51162	12041-20000-06098	5841-5845 W CARLTON WAY	90028	13	148-5A191 205	5545004011	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.10059	-118.31725	New 5-story affordable housing apartment with 40 units over parking garage.  New 2000A service.  Plan check for power and energy.Note: Fire Alarm system submitted under 12041-10000-15727	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51163	16041-20002-33814	1915 N HYPERION AVE	90027	4	147A203   184	5430013021	C1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			Corrections Issued	08/01/2017 12:00:00 AM	ADDRESS	34.0977	-118.27553	Title 24 energy plan check only.  (((Supplemental Permit# 16041-10000-33814 change of address from 3808 w Udell CT to 1915 Hyperion Ave changed use code from sfd to commercial reference building Permit #16016-20000-10490)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51164	15041-10000-03570	3481 W OLYMPIC BLVD	90019	4	129B189   213	5081025020	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.05276	-118.31427	Plan check for power and energy (7 Eleven) 800Amp service with 5 panels. Total area: 2684SQ	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51165	19041-20000-39872	18342 W EDDY ST	91325	12	195B125   933	2786003027	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.22767	-118.53297	TENANT IMPROVEMENT FOR AN OFFICE P.C FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51166	19041-20000-00961	9703 S EVERS AVE pv1	90002	15	093A213   404	6048006021	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	33.94813	-118.24726	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.  (1) tesla battery 5KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51167	19041-10001-49397	10720 W CHALON ROAD	90077	5	141B149   146	4362003035	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			Verifications in Progress	04/06/2020 12:00:00 AM	ADDRESS	34.08291	-118.44997	EXPEDITE FEESPV1, PLAN CHECK FOR A NEW ROOFTOP SYSTEM, SYSTEM SIZE IS 28.8 KWaC, SCOPE OF WORK IS 80 MODULES (SOLARIA POWERXT-360R-PD) WITH OPTIMZERS (SE P740) LEADING TO TWO CENTRAL INVERTERS (SE14.4KUS) THAT LEADS TO A AC COMBINER BOX, TERMINATING IN A NEW 800A SERVICE. NEW MAIN SERVICE AND SERVICE PANEL TO BE SEPRATELY PERMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51168	14041-10000-17623	1600 N VINE ST	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Approved	07/14/2014 12:00:00 AM	ADDRESS	34.1	-118.32647	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT ON THE 11TH FLOOR. CONFERENCE ROOM AND BATHROOM. 1340 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51169	18041-10001-40388	1150 S OLIVE ST 1200	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.03962	-118.26181	[[CHANGES TO APPROVED T24 ENERGY. PLANCHECK ONLY. CHANGING LIGHTING LAYOUT AND T24.]]]PLAN CHECK FOR ENERYGY ONLY TO AN INTERIOR OFFICE T.I. NO CHANGE OF USE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 9510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51170	15041-10009-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Application wanted to stamp an extra set of plans for 15041-10007-07080. This aplication covers 1 pc hour to verify that approved plans where the same on new set.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51171	13041-20000-34055	8360 N SEDAN AVE	91304	12	192B097   260	2005005024	A1-1XL	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.22167	-118.63032	PC FOR T24 ENERGY ONLY. EXTERNALLY ILLUMINATED SIGNS. COMMON AREA OF RESIDENTIAL COMMUNITY. TOTAL AREA FOR ENERGY 24 SW FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51172	12041-10000-20439	1888 S CENTURY PARK EAST	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			Corrections Issued	08/29/2012 12:00:00 AM	ADDRESS	34.06104	-118.41402	TI for stairway between 2nd & 3rd floor. Epc is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51173	18041-10000-22727	13935 W FOOTHILL BLVD	91342	7	225B153   306	2509002024	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.31284	-118.43692	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51174	11041-20000-11812	865 S FIGUEROA ST STE 2610	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			PC Approved	06/08/2011 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR TENANT IMPROVEMENT SUITE #2610	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51175	15041-20000-15535	11310 N TAMARACK AVE	91340	7	210B153   101	2616017022	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.27551	-118.43641	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Central inverter system with 2 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51176	14041-20000-00541	1321 N SYCAMORE AVE	90028	4	144B181    34	5548022064	RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			01/08/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.09499	-118.34295	Change to lighting in the lobby of an existing low-rise apartment building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51177	16041-10001-21571	2645 S CRENSHAW BLVD	90016	10	123B185   910	5050001027	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.03125	-118.33541	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED ON PLANS, REVISION 6/9/17. INCLUDES CHANGES TO SERIES RATING SYSTEM AND CHANGES TO UNIT LIGTHING. PROVIDED ADDITIONAL RECEPTACLES FOR CORRIDOR AREAS. PC ONLY. PERMIT UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51178	11041-20000-18367	1831 N WHITLEY AVE 1-31	90028	4	150A185   306	5547004037	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	ADDRESS	34.10427	-118.33347	NEW 800A SERVICE UPGRADE, 13 SUBPANELS, AND 13 DWELLING UNITS. 18  DWELLING UNITS' PANELS, BRANCH CKTS ARE EXISTING TO REMAIN. FIRE DAMAGE REPAIR APT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51179	12041-10000-05379	1225 N ANGELO DR	90077	5	144B153   384	4357012004	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2012 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.09252	-118.43395	Plan check ground mounted 15.36KW Enphase M215 Microinverter photovoltaic system installation for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51180	12041-10000-28827	2445 N DALY ST 3RD FLOOR	90031	1	139-5A221 259	5204004803	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.07502	-118.21584	TI IN AN EXISTING COMMERCIAL SPACE ON THE 3RD FLOOR. (3RD FLOOR DC SWITCH ROOM)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51181	17041-10000-46307	1918 W 7TH ST	90057	1	132A203   168	5142003001	C2-2	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.0556	-118.27524	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51182	16041-20000-17858	1318 E 7TH ST #524	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.03608	-118.24052	Plan check for Title 24 only in existing building. Total area: 10,722 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51183	17041-20000-39148	18681 W HILLSBORO ROAD	91326	12	207B121   586	2728030013	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Issued	11/15/2017 12:00:00 AM	ADDRESS	34.26275	-118.54005	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (38) modules. System is interconnecting with a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51184	13041-20000-08481	18080 W CHATSWORTH ST 1-6	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.26439	-118.52639	Change to lighting, loads in an existing restaurant space.   Load is less than 400 amps and occupancy load is less than 99 people per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51185	15041-20000-09465	5424 S CRENSHAW BLVD	90043	8	108B185   458	5006008008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	33.99235	-118.33045	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 10.5 KW.  35 CANADIAN SOLAR MODULES(5 )GRO WATT INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51186	17041-10000-18846	8025 N HASKELL AVE	91406	6	189B141    42	2206004011	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.21671	-118.47512	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51187	19041-10000-50154	13620 S VERMONT AVE	90247	15	078B197   325	6119001005	RD3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	33.90752	-118.29131	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 18 (HYUNDAI HIS-370KI) MODULES, 18  (ENPHASE IQ7PLUS-72-2-US) MICRO INVERTERS, CONNECTED TO A 100A MAIN SERVICE PANEL. SYSTEM SIZE IS 6.66KW DC & 5.22KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51188	17041-10000-39398	189 S THE GROVE DR Q10-A	90036	4	138B177  1132	5512003042	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	34.07125	-118.35662	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN AN EXISTING MERCANTILE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 598 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51189	13041-20000-33073	9838 N CHICOPEE AVE	91325	12	201B129   115	2755013018	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.24986	-118.51353	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE IS 12KWAC. 51 MODULES AND 2 INVERTERS(($0.00 Permit fee due to Senate Bill)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51190	11041-20000-27619	23750 W NADIR ST	91304	12	192B089    62	2005021006	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2011 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.22019	-118.64528	Roof mounted photovoltaic system, SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51191	13041-10003-32334	5448 W HOLLYWOOD BLVD	90027	13	148-5A193 151	5544021910	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.10157	-118.30874	PLAN CHECK ONLY. CHANGES TO AN APPROVED SET OF PLANS, CHANGES UNDER CLOUDED AREAS. CHANGES INCLUDE THE REVISION OF LIGHTING PLAN AD T- 24 FORMS. 2008 ENERGY CODE. _________________________________________________________________PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES REVISONS TO SPACE LAYOUT AND REDESIGN OF ELECTRICAL SYSTEM.  INCLUDING NEW METER AND PANEL  AND ADDITIONAL CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51192	19041-10000-37790	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	10/27/2020 12:00:00 AM	ADDRESS	33.79173	-118.23549	Power plan check for a new installation of (2) new 600-Amp section, (2) new  480v 100-HP compessor skids, and other associated equipment located in a refinery hazardous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51193	19041-20000-34297	20312 W STRELNA PL	91364	3	168B113   171	2174003046	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.15838	-118.5758	PV1.  Install 9.3 kW roof mounted grid tied PV system.  (30) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51194	17041-20001-31656	6461 N PEACH AVE	91406	6	180B145   590	2234015005	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.18838	-118.46781	Expedited plan check fee. PV1.  Install 13.44 kW roof mounted grid tied PV system.  Microinverter system with (40) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51195	12041-10000-05843	5202 W ZOO DR	90027	4	168B193   134	5581001906	OS-1XL	Central	Hollywood	Greater Griffith Park	YES	1882.00	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM	03/15/2012 12:00:00 AM		Permit Finaled	07/24/2012 12:00:00 AM	ADDRESS	34.15524	-118.30207	PLAN CHECK T24 ENERGY (INDOOR AND OUTDOOR) FOR TICKET OFFICE AND RESTROOM FACILITY. PERMIT FOR 5 BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51196	15041-10000-07964	438 S MAIN ST	90013	14	129A211   137	5148009013	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM			Reviewed by Supervisor	05/01/2015 12:00:00 AM	ADDRESS	34.04716	-118.24785	PC FOR POWER AND ENERGY. REMODELING EXISTING BUILDING.( change of use of existing retail to bar ).TOTAL AREA 1776 SQ FT. FEE CALCULATION PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51197	13041-20002-05727	6600 N TOPANGA CANYON BLVD #51	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	"Change to approved set of plans to change feeder ""T1"" size only.  PLAN CHECK ONLY for Clouded Delta 5 Only (Feeder only).        <<<<PLAN CHECK FOR POWER AND ENERGY FOR EXISTING RESTUARANT SPACE (CHANGING FROM CALIFORNIA PIZZA KITCHEN TO CHEESECAKE FACTORY).INDOOR AND OUTDOOR LIGHTING: 17130 SQRFT. SERVICE UPGRADED TO 1200A.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51198	17041-10000-00078	8500 W BEVERLY BLVD UNIT 746	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR ENERGY ONLY. TAILORED METHOD . TENANT IMPROVEMENT TO EXISTING RETAIL STORE. TOTAL AREA 2428 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51199	18041-10000-01694	2301 E 1ST ST	90033	14	127-5A223 111	5183005008	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04426	-118.21065	INTERIOR LUMINIARES MODIFICATION IN PLACE - REPLACE WITH LED LUMINAIRES AND LED DRIVERS-AT A CHASE BANK; WIRING, CIRCUITS AND CONTROLS REMAIN AS-ISSIMILAR MODIFICATION FOR EXTERIOR LUMINAIRESPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51200	13041-20003-03947	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	34.0346	-118.45665	Changes from previously approved plans.  Permit issued under 20001 PCIS #.  Addition of one outdoor building sign resulting in changes to title 24 compliance sheets.*****Previous Description*****changes to approved set of plans. changes to site lighting. t24 only. pc only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51201	16041-20002-19398	3239 N PASADENA AVE Unit A	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/30/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	Revisions to approved set.  Change of inverter type from central inverter to microinverters.  $0 plan check fee due to State Senate Bill SB-1222(((PV2.  Install 1.71 kW DC roof mounted PV system.  (6) modules with (1) 3 kW transformerless inverter with power optimizers.  1 of 3 PV systems proposed for property submitted concurrently.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51202	14041-10000-34843	1824 N APEX AVE	90026	13	144A207    69	5423028017	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.09018	-118.26245	Plan check for a PV1 roof-mounted PV system. System size is 8.6 kWac. System consists of (2) inverters and (45) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51203	17041-10000-45719	1128 N HYATT AVE	90744	15	033B209   538	7423027058	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	33.78589	-118.25403	PC for SFD rooftop PV 6kW system. Installing 6kW inverter with 20 modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51204	19041-30000-22291	13434 W SATICOY ST	91605	2	186B157   180	2303024016	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.20873	-118.42593	$0 permit fee due to SB1222 and AB1414Plan check for a PV2 roof-mounted PV system. System size is 39.6 kWdc/35.484 kWac-CEC and consists of (1) 30 kWac rated inverter, (120) modules with (60) optimizers, and (1) 45kva transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51205	19041-20000-09945	19231 W VICTORY BLVD unit 100	91335	3	180B117   799	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.18678	-118.55214	ti to an existing commercial space (dental office).  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51206	14041-10000-19405	658 E VENICE BLVD	90291	11	108B145  1620	4237002006	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM			Verifications in Progress	10/10/2014 12:00:00 AM	ADDRESS	33.98963	-118.46093	Installation of roof mounted PV solar power system.  Total system size = 34.2 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51207	11041-10000-11897	132 S BEAUDRY AVE	90012	1	133-5A209 403	5152023008	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	06/09/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.05825	-118.25476	TI IN AN EXISTING OFFICE AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51208	16041-10000-07976	17331 W PARTHENIA ST	91325	12	195B129   402	2768016005	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.2287	-118.51244	PV1, NEW 15.70 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(48) MODULES: SUNPOWER SPR- E20-327-C-AC(48) MICROINVERTER: SUNPOWER E20-327-C-AC-GEN 2.2	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51209	19041-20000-05437	840 N OGDEN DR	90046	5	141B177    49	5527004004	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.08657	-118.35935	INSTALLING 1 NEW TESLA  ENERGY STORAGE SYSTEM ON EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51210	19041-10002-16599	6823 S LA CIENEGA BLVD	90045	11	102B173   135	4103001009	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	33.97634	-118.37052	Delta 5 changes, scope of work includes the revision of conduit routing and counduit runs. Note all changes on clouded areas.  Original scope of work: (((PLAN CHECK FOR NEW SERVICE. SERVICE SIZE 3000A.M SCOPE OF WORK INCLUDES (1) 400A HOUSE PANEL, (1) 3000A SERVICE, (1) 1600A PANEL, A 3000A PULL SECTION. AREA IS A METHANE BUFFER ZONE. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 213,498 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51211	19041-10000-53103	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Issued	02/18/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	TITLE 24 ENERGY PLAN CHECK ONLY. SCOPE WORK INCLUDES ADDING NEW LUMINAIRES TO A TI. TOTAL AFFECTIVE AREA:2907 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51212	17041-10000-10690	630 W 5TH ST	90071	14	130-5A209 151	5151025905	PF-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.05063	-118.25491	TI TO LIBRARY AREA. CREATE NEW COUNTER TOP READING AREA. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51213	10041-10000-16108	5432 W 102ND ST	90045	11	090B173   212	4129033008	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Public Safety Only			08/17/2010 12:00:00 AM	10/18/2010 12:00:00 AM		Permit Finaled	12/26/2013 12:00:00 AM	ADDRESS	33.9435	-118.37523	REPLACING AN EXISTING FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51214	18041-10000-32176	1331 N CAHUENGA BLVD	90028	13	147A187   342	5546017031	(T)(Q)C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	09/02/2021 12:00:00 AM	ADDRESS	34.09556	-118.32924	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM PANEL AND 1559 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51215	13041-20000-00095	22530 W ITASCA ST	91311	12	201B097   160	2727001003	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.2443	-118.61811	PV system on roof of single family dwelling with three transformerless inverters and PV sub panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51216	12041-20000-29339	14117 W HUBBARD ST UNIT 2	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.29849	-118.44081	Plan check for power and energy. First time tenant. Unit 2. 794 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51217	15041-10002-06557	14640 W VICTORY BLVD	91411	6	180B149   895	2241003007	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.18644	-118.45224	((((4/22/2015))))changes to an approved set of plans.  changes noted delta 2. plan check only.    (((4/10/2015- CHANGES MADE TO APPROVED SET. CHANGED FIXTURE A TO 60 WATTS. ENERGY CALCULATIONS TO BE RE-VERIFIED. THIS IS A PLAN CHECK ONLY APPLICATION)))Energy plan check for a change of use from a retail to a daycare center. Total area is 6315-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51218	19041-10000-34080	9111 S FALMOUTH AVE	90293	11	093B153    73	4118013915	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	33.95388	-118.43436	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51219	14041-20000-32220	17137 W INDEX ST	91344	12	210B133    88	2697013013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.27571	-118.50627	PV1 SFD. TOTAL SYSTEM SIZE 7.2KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51220	18041-20000-37299	20724 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.2929	-118.58518	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51221	17041-20000-36351	17734 W BALTAR ST	91335	12	189B129   300	2101005027	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/09/2017 12:00:00 AM	ADDRESS	34.21675	-118.52039	PV1.  Install 2.4 kW roof mounted grid tied PV system.  Derating of main breaker.  (E) solar PV systems on site.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51222	19041-10001-34238	3379 N MANDEVILLE CANYON ROAD	90049	11	150B133   111	4491006010	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	09/18/2019 12:00:00 AM	ADDRESS	34.10464	-118.50377	EXPEDITED PLAN PLAN CHECK FOR ROOF MOUNTED 11.4 PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 43 MODULES USIGN P400 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51223	10041-10000-14019	830 N VERMONT AVE	90029	13	141B197    37	5539015024	[Q]C2-1	Central	Hollywood	East Hollywood	YES	1914.20	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			PC Approved	07/21/2010 12:00:00 AM	ADDRESS	34.08631	-118.29154	renovation of a jackin- the box restaurant. Plan chk is for title 24. (Permit was pulled under # 10041-10000-07176)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51224	18041-10000-20618	8530 N BALBOA BLVD	91325	12	192B133    87	2689019011	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.22605	-118.50242	PLANCHECK FOR POWER ONLY. ADDITION OF EV CHARGERS. PART 2 OF 2. PLANCEHCK DUE TO APPLICANTS REQUEST. EV CHARGERS INSTALLED IN TWO BUILDINGS. MAIN BUILDING IS 8510 N BALBOA ( 18041-10000-20615)BUILDING PERMIT # 18020-10000-00234	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51225	16041-10000-00232	12025 W VOSE ST #5	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.3952	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51226	14041-10000-30292	6111 S GRAMERCY PL	90047	8	105B189   843	6001012022	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	33.98411	-118.31358	Power plan check for a 1600 Amp service equipment replacement,  plan also include installation of 2 new panels and a transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51227	19041-10000-31831	8732 S WESTERN AVE	90047	8	096A193    48	6037014028	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.95817	-118.30883	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51228	11041-10000-10975	747 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM			Verifications in Progress	08/22/2011 12:00:00 AM	ADDRESS	34.03186	-118.23915	NEW PARKING LOT LIGHTING.  T-24 FOR OUTDOOR LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51229	17041-10000-13049	111 N GLENDALE BLVD	90026	13	135A209   357	5159014020	C2-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			PC Approved	04/21/2017 12:00:00 AM	ADDRESS	34.06267	-118.25989	Title 24 plan check.  Interior T.I. to existing two story office building.  Convert lobby to gym on level 1.  3 new panels with one new 75 kVA transformer.  New lighting and receptacles.  Total area = 7,831 sq. ft.     Building permit #17016-10000-06406	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51230	19041-30000-09822	6360 W SUNSET BLVD	90028	13	147A187   584	5546015047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.09774	-118.32782	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 208 sq. ft.Note: Building application has been generated under 18016-10000-40042	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51231	17041-10000-39755	5711 W CENTURY BLVD	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	33.94573	-118.38128	at the lax hilton, replacing Porte Cochere lighting and controls with new LED lights and programmable Dimmer RackPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51232	16041-10000-38087	10250 W SANTA MONICA BLVD # 1320	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			PC Info Complete	11/10/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Jo Malone"" Ste. 1320.  Install new panels and its circuits, lights and receptacles. Total effected area: 599 sq.ft. using performance method."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51233	19041-20000-22747	7857 N BURNET AVE	91405	6	189B145   476	2209032025	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.2136	-118.46305	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of from warehouse to hydroponics agricultural enterprise. Total lighting area = 1,866 sq. ft.Note: Building permit has been issued under 18016-20000-38271. This scope of work only includes lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51234	12041-20000-22402	7344 N LAUREL CANYON BLVD	91605	6	186B165   550	2317015009	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.20413	-118.39608	Plan check for energy and emergency lighting. 9543 sqft (3146sqft unconditioned sqft).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51235	19041-10000-30952	4080 S GLENCOE AVE	90292	11	108B153  1429	4230030***	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	02/13/2020 12:00:00 AM		Permit Finaled	05/04/2020 12:00:00 AM	ADDRESS	33.99044	-118.44306	INSTALLATION OF 16 FUTURE ELECTRICAL VEHICLE CHARGERS TO A CONDO SPACES. TOTAL NEWLY ADDED LOAD > 400AMP	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
51236	17041-30000-28323	144 N BRISTOL AVE	90049	11	132B137   341	4405020007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM			PC Approved	04/09/2019 12:00:00 AM	ADDRESS	34.05794	-118.48823	Plan check for Single Family Dwelling 2 story 600A Service Plan check for power only. Electrical Permit paid under Building application number: 17010-30000-02685	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51237	19041-10000-17096	12027 W VENICE BLVD 1-4	90066	11	114B157  1270	4248029042	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Apartment			05/07/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.00603	-118.42987	PC for FA Proposed Type V-B 2 stories w/ mezz 4 units apartment over one story office / garage mixed use building ( 3 stories w/ mezz total ) and restrip existing parking lot.1 FACP and 11 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51238	18041-10000-22730	11862 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.28593	-118.50158	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51239	14041-10000-08548	12501 N GLADSTONE AVE #A-4	91342	7	219B161   211	2525018061	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.29709	-118.41363	Title 24 only. Remove HID light fixtures and replace with new fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51240	17041-30000-43090	386 S BURNSIDE AVE T34	90036	4	135B181   159	5509005008	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	05/14/2018 12:00:00 AM		Issued	05/14/2018 12:00:00 AM	ADDRESS	34.06796	-118.35215	Existing High-rise residential Building. Plan check for Core and shell power only Service upgrade to 4,000A 120/208V and distribution. Existing emergency generator. Replace new panel inside each unit, use exising panel as J-box and extend to new panel. All load existing to remain. This project is in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51241	13041-10000-03510	236 N BUNDY DR	90049	11	135B141   805	4402011007	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.06268	-118.47638	photovoltaic system for single family single story dwelling. total system size of 7.5 kw. using 30 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51242	14041-20000-10671	915 W WILSHIRE BLVD 7th floor	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI to 7th floor of (E) commercial high-rise building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51243	15041-20000-37009	6148 N CAHUENGA BLVD	91606	2	177B177   336	2414021003	R2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.18263	-118.3614	PV1, roof mounted solar panel, 4.24kW system(16)modules: #KU2656ZPA(1) INVERTER: pvi-3.6-outd-s-usStandrad plan is used	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51244	14041-20000-05564	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.0352	-118.45736	PLAN CHECK FOR ALL NEW ELECTRICAL EQUIPEMENT FOR EXISTING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51245	12041-20000-28370	8810 N TAMPA AVE	91324	12	195B121   511	2784003069	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	02/22/2014 12:00:00 AM	ADDRESS	34.23097	-118.55317	Plan check for power. Installation of an additive tank for gasoline. COSTCO. HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51246	13041-10000-22580	8000 W SUNSET BLVD 3RD FLOOR	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.09783	-118.36466	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING FOR A TENANT IMPROVEMENT.  3RD FLOOR OF AN OFFICE BUILDING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51247	17041-10000-11986	1815 E BRIDGE ST	90033	14	130-5A221 194	5174005038	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.05145	-118.21528	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 28500 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51248	19041-20000-38809	5757 W WILSHIRE BLVD 601	90036	4	135B177   594	5508015009	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 Energy only in existing space, Tenant Improvement. Total area: 2425 sq ft. B#19016-10000-20390	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51249	19041-10000-50232	9204 S CENTRAL AVE	90002	9	094-5A209 188	6049001029	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	05/29/2020 12:00:00 AM		Permit Finaled	06/22/2021 12:00:00 AM	ADDRESS	33.95302	-118.25622	FULL PC FOR A NEW 800A SERVICE (120/240V 3P,4W) WHICH FEEDS  2 EV CHARGERS AND SEVEN HOUSE PANELS. TOTAL AFFECTED AREA IS 17,905 SFQT. PER BUILDING ((CHANGE OF USE FROM (E) RETAIL TO (N) 1-STORY COIN LAUNDRY; RESTRIPE PARKING LOT.17016-10000-36084))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51250	15041-20000-05168	730 N BONHILL ROAD	90049	11	138B141   480	4494013018	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2015 12:00:00 AM			PC Info Complete	05/07/2015 12:00:00 AM	ADDRESS	34.07167	-118.48198	2 STORY ADDITION OVER BASEMENT TO (E) 1-STORY SFD W/ATT GARAGE.  New 600A service and complete rewire.pc only. permit issued from building dept.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51251	17041-10000-46305	2400 W OLYMPIC BLVD	90006	1	130-5A201 143	5136003018	C2-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.05222	-118.28386	REMOVE INDOOR AND OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51252	14041-20000-10996	19755 W VANOWEN ST A6	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM			PC Info Complete	07/03/2014 12:00:00 AM	ADDRESS	34.19397	-118.56386	First time tenant for restaurant in core/shell building.  Install branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51253	19041-10000-19730	7324 N CANBY AVE	91335	3	186B125   789	2119021044	[Q]C2-1VL-CDO, [T]R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.20383	-118.53463	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51254	13041-20001-31894	12833 N SEAGLASS	90094										Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM				((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KW. USING SOLADECK RELAY ON DC SIDE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51255	15041-10000-13060	11214 W MORRISON ST	91601	2	168B173    16	2353016003	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.16065	-118.37499	NEW FA SYSTEM FOR A NEW 6-UNIT ,3-STORY APARTMENT BUILDING. 38 FA DEVICES AND 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51256	15041-20000-19863	11453 N VIKING AVE	91326	12	213B121   530	2871004005	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.27932	-118.54545	Installation of new roof mounted solar PV array.  Total system size = 3.75 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51257	15041-10000-12406	16304 S VERMONT AVE	90247	15	069B197   333	6120018084	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	33.88328	-118.29117	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 36KW INTERCONNECTED WITH MSP.  (6) SMA 6000 WATTS INVERTERS(156) CANADIAN SOLAR MODULES CS6P-255P MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51258	12041-10000-06823	3555 N FIGUEROA ST #M	90065	1	144A223   141	5446002037	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.02	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Info Complete	05/22/2012 12:00:00 AM	ADDRESS	34.08957	-118.21405	First time tenant for an Eye Doctor,  Suite M on the 1st floor.  Plan check for Power and Energy.  Not to be a state licensed facility, not checked for OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51259	19041-10000-39261	743 N LILLIAN WAY 1-14	90038	13	141B185   355	5533032021	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			09/30/2019 12:00:00 AM			Reviewed by Supervisor	12/02/2019 12:00:00 AM	ADDRESS	34.08469	-118.32785	Full plan check for a new  3 story 14 unit apartment , type VA,  over basement type IA garage.scope icludes new 800a service. Fire Varience submitted. B#19010-20000-03502	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51260	14041-20001-15459	2522 S ANCHOVY AVE	90732	15	012B189   529	7563036016	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	33.72529	-118.32118	microinverter enphase m250. using nonstandard plan. total system size 7.9kw ac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51261	13041-10000-35300	5842 N COSTELLO AVE	91401	2	174B153   122	2246014002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.17697	-118.43765	Pv1, Install 7 kw DC roof-mounted solar array for a one story building,(28) Renesola JC250M-24/Bb solar modules,(1) Solaredge SE6000A-US inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51262	14041-20000-12450	8588 W APPIAN WAY	90046	4	150B169   786	5562012018	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.10784	-118.37964	Roof mounted PV system with transformerless inverter, syste size 8.84KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51263	16041-20000-17354	13544 W GAIN ST	91331	7	204B157   975	2646017021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	PIN	34.25373604	-118.4276565	PV1.  INstall 4.25 kW PV system.  Central inverter standard plan.  (17) modules with (1) 3 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51264	19041-20000-23962	10828 W VIA VERONA	90077	5	147B145   114	4377037017	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.09911	-118.4588	Install 13.5 kWh energy storage system, added to (E) 27 kWh energy storage system, and subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51265	17041-20002-38045	1015 S ORANGE GROVE AVE	90019	10	132B177   718	5086001053	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM			PC Approved	05/04/2018 12:00:00 AM	ADDRESS	34.0575	-118.36311	5/4/2018Changes to an approved set of plans.  Changes to replosition location of performance meter and AC disconnect.  This is plan check only. ((((Plan check for solar pv system, roof-mounted array on commercial building.Total system size: 20kW ungrounded.(2) 10kW SolarEdge inverters.(91) 300W pv modules.(91) 300W power optimizers.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51266	14041-20000-00054	18725 W SHERMAN WAY	91335	3	183B121    99	2118026018	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM			Reviewed by Supervisor	01/06/2014 12:00:00 AM	ADDRESS	34.20128	-118.54148	(((T24 FOR CHG OF USE FROM RETAIL TO ADULT DAYCARE. DINING AREA EXCEEDS 100 OCCUPANT LOAD.)))IGNORE THIS APPLICATION.  APPLICATION HAS BEEN RESUBMITTED UNDER SUPPLEMENTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51267	16041-20000-21232	10350 W DIAMOND ST LOT 16	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51268	17041-20000-19512	5518 N KEOKUK AVE	91367	3	174B113   333	2151012073	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.17291	-118.57458	Plan check for a PV1 roof-mounted PV system. System size is 12.4 kWac and consists of (36) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51269	16041-20004-38115	21425 W VANOWEN ST	91303	3	183B105   951	2138011023	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			PC Approved	09/21/2018 12:00:00 AM	ADDRESS	34.19399	-118.59858	9/21/18changes to an approved set of  plans.  changes noted delta 7 only.  changes to revise lighting fixtures and update energy calculations.  no change in load no new equipment.  this is plan check only.  ((((Full PC for new 6 story with 1 level of basement. 174 unit apartment. All new equipment. (2) New main switchboards rated at 5000A 120/208V 3 phase 4wire AND 2000Amps 120/208V 3phase 4wire. 17 typical units. Total sqft = 126,537.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51270	14041-10000-07391	21550 W OXNARD ST	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM			PC Info Complete	04/25/2014 12:00:00 AM	ADDRESS	34.179	-118.60001	INTERIOR OFFICE TI; EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51271	14041-10002-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	Changes to approved set.  New lighting fixtures used.  New lighting layout in parking garage levels A and B.  New euipment layout in electrical rooms.  New IT rooms and elevator.  Addition of elevator control rooms and security room.  Relocating connections to two switchboards (MS-ELB41 & MS-ELA42).  Tenant list has been revised with load calculations and feeder schedule updated accordingly.  Lighting and power floor plan seperated into two floor plans.   All changes are clouded with delta 19.This project is phase 3 of Westfield Century City which includes all underground areas and parking garage areas plus main service, switchgear, conduits, and distribution panels for tenants.NOTE: Modification of building ordinance has been filed for addition of loads to an existing installation that is not in immediate compliance with section 220.87.  7 day meter readings have been submitted at initial time of plan approval.  30 day meter readings shall be provided for plan check approval prior to finalizing of the project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51272	18041-20000-36253	23912 W SCHOENBORN ST	91304	12	192B089   139	2017037007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.22082	-118.64745	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (2) Tesla PowerWalls onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51273	17041-20000-45635	8335 N SPARTON AVE	91402	6	192B157   605	2637034020	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			Reviewed by Supervisor	12/28/2017 12:00:00 AM	ADDRESS	34.22247	-118.42589	PV1.  Install 14.26 kW AC roof mounted grid tied PV system.  (58) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51274	19041-10000-08666	3201 N FLETCHER DR	90065	13	154-5A213 168	5458017003	[Q]C1-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.11699	-118.24313	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51275	19041-20000-42825	7820 W ELECTRA DR	90046	4	150B177   314	5569018062	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	34.10588	-118.3631	PV1.  Install 17.280 kW DC / 15.568 kW CEC-AC roof mounted grid tied PV system.  (48) modules with 11.4 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51276	19041-10000-02776	6464 N CANOGA AVE	91367	3	180B105    56	2149001030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.18795	-118.5972	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51277	15041-20001-38547	14345 W NORDHOFF ST	91402	6	198B153   901	2639010001	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.23554	-118.44501	EXPEDITE PER APPLICANT REQUEST{{{{{{{Plan check for PV roof mounted system. System size: 18.5kw with 71 modules(Kyocera) and 2 inverters(7.6kW and 8.2kW) connectted to load center.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51278	18041-20000-12019	1555 S WESTERN AVE	90006	10	126B193   267	5073011028	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.04389	-118.30926	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,640 sq. ft.Note: Building application has been generated under 18016-20000-10056	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51279	16041-10000-19864	1326 E MORNINGSIDE WAY	90291	11	114B149  1031	4244020032	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Issued	06/07/2016 12:00:00 AM	ADDRESS	34.00506	-118.45521	PV1 rooftop solar 3.6kW AC system.   (18) KU2656ZPA   (1) PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51280	10041-10000-07447	777 E 10TH ST 1-78	90021	9	124-5A211 244	5132002028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	05/05/2010 12:00:00 AM	ADDRESS	34.03437	-118.24974	FIRST TIMME TENANT, TITLE 24 , POWER AND LITHING. PANELSAND TRANSFORMER ARE EXISTING. uNIT TO BE ISPECTED #   101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51281	14041-20000-26926	555 S FLOWER ST SUITE 2000	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.05048	-118.25755	PC FOR T24 ENERGY ONLY. 2013 BUILDING EFFICIENCY STANDARDS. TI TO CONFERENCE ROOM. NEW LIGHTING. WORK DONE ON 24 FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51282	15041-10000-20177	10821 N ARLETA AVE	91345	7	207B149   196	2615025013	RA-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM			Reviewed by Supervisor	08/11/2015 12:00:00 AM	ADDRESS	34.26661	-118.45112	PVI, INSTALL 13.4 KW DC ROOF--MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(41) MODULES: SUNPOWER SPR327NE-WHT(2) INVERTERS: POWER ONE PVI-6000 OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51283	14041-20000-36054	7232 N WHITEHALL LANE	91307	12	186B089   706	2027023044	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2014 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.20259	-118.65333	PERMIT FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service pannel. (57) KD 200-60 modules(2) PVI-6000 TL inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51284	16041-10000-14326	5259 W PICO BLVD	90019	10	129B181   879	5085036021	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.04842	-118.353	TI to an (E) commercial build. due to fire damage.  PC for Energy only, total area 2259 sq.ft.B#16016-10000-09167	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51285	14041-20000-34646	523 W 6TH ST 702	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	Plan check for energy only. TI to existing office on 7th floor of high rise office building. New lighting (incl. emergency) and receptacles. 440sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51286	14041-10000-13391	3771 W AVENUE 42	90065	1	156A219   175	5472001006	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.12117	-118.22387	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51287	15041-10000-34441	626 W WILSHIRE BLVD 12 FLR	90017	14	129A209    83	5144006025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.04843	-118.25695	NEW 1200 AMP CIRCUIT BREAKER TO FEED AN EXISTING ATS FROM PANEL BOARD SWBD.  PLAN CHECK FOR POWER ONLY.SWBD LOCATED ON THE 12 FLR CONDUIT RUN TO THE 6TH FLR TO THE EXISTING ATS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51288	12041-10000-18072	630 W HARRY BRIDGES BLVD MAIN GATE	90744	15	027B205   442	7440006***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	04/19/2013 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	33.77068	-118.26868	Main Gate and Main Enterance.  Plan check power  for new 400A switchboard, Main Entrance, high mast poles. Location in Methane Zone . Rear Berth 136-139.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51289	13041-10000-35180	6091 W SUNSET BLVD	90028	13	147A189    50	5545008400	[Q]C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.09819	-118.32187	Plan check for T24 only. One new  branch circuit for mergency lighting. Two story building and first floor for bakery store with the dinning option. Area 1197 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51290	14041-10000-21142	3556 S SAWTELLE BLVD	90066	6	117B157   583	4249032043	R3-1	West Los Angeles	Palms - Del Rey - Mar Vista			2718.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	PIN	34.01546922	-118.42258736	PV1, INSTALL 5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(20) MODULES: TRINA SOLAR TSM-255A05.18(1) INVERTER: SOLAREDGE SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51291	15041-20001-25412	2727 S LA CIENEGA BLVD	90034	10	123B173   749	5065004025	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	34.03316	-118.37578	Expedite fees only.  Installation of new roof mounted solar PV on existing commercial building.  Total system size = 14 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51292	19041-10000-18567	865 S FIGUEROA ST 31ST FLOOR	90017	14	129A207   241	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.04653	-118.26275	PC FOR ENERGY OFFICE TENANT IMPROVEMENT TO INCLUDE NEW PARTITIONS, NEW FLOOR, WALLS AND CEILING FINISHES. (5,500 SQFT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51293	14041-20000-02901	20209 W GRESHAM ST	91306	3	195B113   187	2781032027	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.23088	-118.57377	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51294	19041-20000-17274	19957 W CANTARA ST	91306	3	192B113   664	2106001038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.21894	-118.56859	PV1.  Install 5.94 kW DC / 5.55 kW AC roof mounted grid tied PV system.  (18) modules with 6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51295	13041-10000-33033	1160 N RAVOLI DR	90272	11	129B133   144	4425010019	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Expired	02/11/2016 12:00:00 AM	ADDRESS	34.05107	-118.50789	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 7.5 KW. STANDARD PLAN(30) TRINA SOLAR # TSM-250(1) FRONIUS IG PLUS 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51296	12041-10000-19255	960 E 12TH ST	90021	9	123A211   213	5132013029	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	34.03119	-118.24802	This is a one story existing bldg,  Ti work for six identical retail spaces., title 24 and e- lighting. Address covers, 960-962	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51297	13041-20001-35143	11821 N CLONLEE AVE	91344	12	216B137   513	2609005010	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM			PC Approved	12/22/2013 12:00:00 AM	ADDRESS	34.28492	-118.49711	((Expedite fees))PV1 TRANSOFRMERLESS SYSTEM. 3 STRINGS FOR 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51298	16041-10001-19794	9135 W LEANDER PL	90210	4	153B165   323	4388018017	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.11417	-118.39514	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLARSYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE 12.0KWac.(50)MODULES-KYOCERA# KU2656ZPA(2)INVERTER-ABB # PVI-6000-OUTD-US--Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51299	13041-10001-35517	7431 N TOPEKA DR	91335	3	186B121   533	2104015019	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.20577	-118.54634	Expedited RSES plan check per applicant request.{{PV1, Install 4.5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (18) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51300	16041-10000-15492	8000 N VAN NUYS BLVD	91402	6	189B149   632	2212028019	[Q]C2-1-CDO, [Q]C2-1VL-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.2163	-118.44852	T-24, PC FOR ENERGY ONLY. CONVERT A PORTION OF AN EXISTING RETAIL SPACE INTO OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3808 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51301	16041-10000-36097	11661 W SAN VICENTE BLVD	90049	11	132B145   504	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.05407	-118.46431	PC FOR T24 ENERGY ONLY. REPLACEMENT OF LIGHTING FIXTURES IN BATHROOM. THIS IS FOR RESTROOMS LOCATED 2ND THRU 9TH FLOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51302	18041-10000-07568	8333 N VAN NUYS BLVD	91402	6	192B149   303	2638038002	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.22236	-118.44896	Full plan check for TI on Walmart, SOW includes: new lightings and power due to floor plan changes, add 102 new circuitry to existing panels. Total area: 15,078 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51303	15041-20000-33960	10777 W WILSHIRE BLVD 1-56	90024	5	132B153   173	4360004219	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			10/13/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.06038	-118.43901	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 314 DEVICES AND 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51304	17041-20000-41616	12700 W VAN NUYS BLVD bldg 19	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	pv2install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51305	15041-10004-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 33 AND DELTA 34 CHANGES - LENGTHS OF SOME FEEDERS WERE REDUCED ; TWO DISTRIBUTION  BOARDS WERE RELOCATED TO EM DISTRIBUTION BOARDSCHANGES ARE CLOUDED AND IDENTIFIED(((((((((DELTA  30 (CHANGES ARE CLOUDED  ON THE PLANS) REVISIONS TO PERMITTED SET OF PLANS.PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51306	12041-20000-01881	18025 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.2649	-118.5256	energy plan check carter's clothing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51307	19041-20000-49532	641 N HOBART BLVD	90004	13	141B193   696	5521004020	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM	07/15/2020 12:00:00 AM		Permit Finaled	10/21/2022 12:00:00 AM	ADDRESS	34.08287	-118.30587	INSTALLATION TO A NEW 800 AMP 240/120 3 PHASE SERVICE. SCOPE OF WORK INCLUDES PANELS, EQUIPMENT, AND LIGHTING. TOTAL AFFECTED AREA: 10934 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51308	07041-10003-23889	311 S GRAMERCY PL APT 1-30	90020	4	135B193   278	5504024015	R4-1	Central	Wilshire	Greater Wilshire		2117.02	Electrical	Electrical	Apartment			04/29/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	09/30/2010 12:00:00 AM	ADDRESS	34.06845	-118.3131	DELTA 5 REVISIONS : ADD SUBPANEL HPB1 TO  HOUSE PANEL HPB TO SUPPLY NEW LANDSCAPE LUMINAIRES ON THE FIRST FLOOR ; 2 EA NEW CKTS TO PANEL HPB TO ENERGIZE 2 EA EMERGENCY STORAGE BATTERRY SYSTEMS WHICH WILL BE THE EMERGENCY SOURCES FOR THE EM LUMINAIRES /EXIT SIGNS IN THE CORRIDORS ON FLOORS 2nd THRU SIXTH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51309	16041-20001-17474	16417 W OTSEGO ST	91436	5	171B137   248	2260002008	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2016 12:00:00 AM			Reviewed by Supervisor	05/24/2016 12:00:00 AM	ADDRESS	34.16274	-118.49038	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (49) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51310	18041-10000-25604	9000 N RESEDA BLVD STE 102	91324	12	195B125   108	2769001022	(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.23439	-118.53589	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR NON STRUCTURAL TENANT IMPROVEMENT OF (E) RETAIL STORE UNDER 13014-10000-04869 - TOTAL AFFECTED AREA = 1294 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51311	13041-20000-25901	19565 W PARTHENIA ST	91324	12	195B117   172	2783025101	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.22837	-118.56015	T24 FOR REMODEL OF EXISTING SPACE. CONVERTING STORAGE SPACE TO HALF OFFICE HALF STORAGE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51312	12041-20000-06952	16710 W VENTURA BLVD 1-125	91436	5	168B137   335	2289020019	(Q)C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Info Complete	04/24/2012 12:00:00 AM	ADDRESS	34.15819	-118.49729	T24 plan check for energy and emergency lighting. Retail store for Equinox Gym. 2414 sqft conditioned area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51313	14041-20000-12843	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.08363	-118.32191	pc for power. 2 new 4160v feeders. serving 2 new service substations. distribution equipment. pc for energy for new lighting in electrical room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51314	18041-10000-13758	4880 N CORBIN AVE	91356	3	168B117   108	2175013019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.15934	-118.56298	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 60 MODULES WITH OPTIMIZERS AND 2 INVERTERS. TOTAL SYSTEM SIZE 18KWDC / 15.2 KWAC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51315	18041-20001-45878	3933 N DIXIE CANYON AVE	91423	4	162B157   432	2373020012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.14155	-118.42412	EXPEDITE PER APPLICANT REQUESTPC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 49 MODULES WITH OPTIMIZERS AND TWO CENTRAL INVERTERS. TOTAL SYSTEM SIZE 15.2KWAC/ 16.17 KWDCINCLUDING NEW LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51316	13041-10002-16112	835 S SAN JULIAN ST	90014	14	126A211   275	5145010020	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM			PC Approved	06/28/2013 12:00:00 AM	ADDRESS	34.0388	-118.25057	BATHROOM REMODEL: ADDING 1 GFI OUTLET, 2 LIGHTS, 1 SWITCH & 2 NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51317	18041-10002-26391	9045 W ORIOLE WAY	90069	4	147B169   770	5560004013	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	Yes	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM			PC Approved	03/27/2019 12:00:00 AM	ADDRESS	34.09694	-118.38765	PC change to an approved set , adding an 3 ATS per DWP request for PV system. original # 18041-10000-26391	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51318	14041-10000-18750	125 S LA BREA AVE	90036	5	138B181   965	5513019041	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.07276	-118.34423	PLANCHECK FOR T24 ENERGY. TENANT LEASE SPACE. BUILDING D1-B. 2230 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51319	15041-10000-17470	6007 S ST ANDREWS PL	90047	8	105B193   569	6001018009	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	33.98484	-118.3116	ADDING NEW FEEDERS TO FUTURE TENENT UNIT 1.  EXISTING SERVICE/SWITCHGEAR.  LOADS TO BE ON SEPARATE PERMIT.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51320	17041-20000-35098	9526 N HUNT CLUB LANE	91311	12	201B097   164	2724011037	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.24356	-118.62166	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.4 KW.$17.93 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51321	18041-10000-37934	23921 W KILLION ST	91367	3	171B089    37	2047011021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.16842	-118.64882	Plan check for PV1 9.631kw AC / 10.8KW DC roofmounted system with (30) AC modules and (1) subpanel interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51322	19041-20000-24626	343 N GLENDALE BLVD	90026	13	136-5A207 349	5159020024	C2-1VL	Central	Westlake	Echo Park	YES	2083.02	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Issued	07/24/2019 12:00:00 AM	ADDRESS	34.06663	-118.26074	Plan check for Title 24 only in existing restaurant Tenant Improvement. Total area: 1008 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51323	11041-10001-25713	18510 W VICTORY BLVD	91335	3	180B125   658	2127012009	C4-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	ADDRESS	34.18638	-118.53642	Revision to approved plans, Delta B. Revision to plan layout , relocate ckts and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51324	18041-20001-07867	1108 N OLANCHA DR	90065	1	154-5A221 369	5475008035	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM			PC Approved	03/30/2018 12:00:00 AM	ADDRESS	34.11601	-118.21663	03/30/2018 Changes to an approved set of plans. The battery back-up system has been removed and the scope of work has been reduced to PV only. *****Previous Work Description*****PV1.  Install 5.525 kW PV system.  13.5 kWh energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51325	14041-10000-34297	10324 N ZELZAH AVE	91325	12	204B129   153	2733001011	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	PIN	34.25783818	-118.52294926	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 1812 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51326	16041-10000-00596	2055 N FIGUEROA ST Store 6689	90065	1	142-5A219 495	5446013057	PF-1, UC(CA)	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.08273	-118.22429	New 210KW fuel cell system, interconnected to (E) service 277/408V. Fuel cell utility interactive.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51327	17041-20001-02806	920 S BERENDO ST	90006	10	132B197   952	5094025017	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			07/25/2019 12:00:00 AM			PC Approved	07/25/2019 12:00:00 AM	ADDRESS	34.05515	-118.29398	7/25/19changes to an approved set of plans.  changes to reflect field conditions, location of MS1.  this is plan check only.  ((((new 1200 amp service to new 4-story, 27-unit apartment building. 3 levels of residential over ground level & subterranean level parking.  plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51328	14041-20000-33051	5871 W PICO BLVD	90035	5	129B173   378	5086003027	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Expired	08/22/2017 12:00:00 AM	PIN	34.05187718	-118.3671302	((circuits existing. only reconnection. 5 new circuits. permit includes code enforcement investigation fees. reconnect the new laundry equipment. power only. no new lighting. )))**COMPLY WITH DEPARTMENT ORDER effective date11/10/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATEInvestigation fee due. Code Enforcement Order to Comply issuedwith effective date 11/10/2014 by Inspector JOHN MATTILLO atphone# (213)252-3035.  CEIS Case Number is 665867.****ti to an existing laundry facility.  existing service and panels.  new washing machines new circuits.  plan check for power only.no lighting nor controls involved.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51329	15041-10000-26336	3019 N FIERO ST	90065	13	156B209   292	5458004025	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.12065	-118.25075	PLAN CHECK FOR ENERGY ONLY. REPLACING EXISTING LIGHTS ON EXISTING CIRCUITS WITH LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51330	16041-10000-18748	2712 W AVENUE 34	90065	1	153A215   179	5457022011	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.11372	-118.23582	PC FOR ENERGY ONLY TO COMMERCIAL BUILDING. CHANGE OF USE FROM BAKERY TO MUSIC STUDIO. INSTALLING NEW LIGTHING AND POWER. TOTAL SQFT = 1680	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51331	18041-30000-05324	1999 S AVENUE OF THE STARS 36th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only in existing high-rise building office T.I. Newly connected load less than 400A Total area: 20,000 sq ft.B#18016-10000-03745	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51332	16041-10000-22133	330 S ALAMEDA ST #A	90013	14	127-5A215 134	5163010007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.04394	-118.23787	PC for T-24 only: Remove HID fixtures and replace with new LED fixtures. Total area: 10,760 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51333	18041-20002-24046	8425 N ZEILER AVE	91402	6	192B157   481	2637014057	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.22364	-118.42564	11/06/2018 Changes to an approved set of plans. MSP has been upgraded to 225 Amps with a MCB of 200 Amps.*****Previous Work Description*****Plan check for PV roof mounted with battery back up system, system size: 7.6kW with 12 modules, 1 inverter(7.6kW) and LG Chem REU 10H.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51334	16041-30000-35046	291 W 22ND ST	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	33.72447	-118.28383	Title 24 plan check.  Remove HID fixtures and replace witn new LED fixtures.  Total area = 52,300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51335	14041-20000-18471	6940 N PLATT AVE	91307	12	183B093   490	2028011010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.1957	-118.64169	PV1 standard plan with string inverter , 6.27 roof-mounted system including (22) LDK-285-24 modules and one Polaredge SE6000A inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51336	19041-10000-16126	1776 N SYCAMORE AVE	90028	13	150B181   705	5548003009	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Apartment			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.1036	-118.3432	TI IN AN EXISTING 3 STORY APARTMENT BUILDING. REPLACING EXISTING LIGHTS IN THE COMMON AREAS WITH NEW LED LIGHTS. T-24 ENRGY ONLY. EMERGENCY LIGHTS ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51337	12041-20000-29189	6640 N VAN NUYS BLVD #201	91405	6	180B149   272	2237001018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.19188	-118.44844	Change to lighting in an existing 2-story office building.   Load is less than 40 amps and occupanyc load is less than 99 people per applicant.  Not a Medical facility per applicant.  PLAN CHECK ONLY for Energy, with NO Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51338	14041-20001-04090	13438 W CANTARA ST PV1	91402	6	192B157   829	2301004029	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.21974	-118.42613	][][ EXPEDITED PER APPLICANT REQUEST ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (N) UPGRADED MAIN SERVICE PANEL. UNGROUNDED SYSTEM, SIZED @ 6.5 kW DC, WITH (26) YINGLY YL250P MODULES, (1) COMBINER BOX, (1) POWER-ONE-PVI-6000-OUTD-US-A INVERTER WITH AFCI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51339	18041-10000-48314	310 S VAN NESS AVE	90020	4	135B189   230	5504023012	R1-1XL-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	34.06846	-118.31498	PLAN CHECK FOR TITLE 24 ONLY FOR MULTI PURPOSE ROOM - TOTAL AFFECTED AREA = 754 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51340	18041-10001-48896	7463 N MASON AVE	91306	3	186B109   467	2113002011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2018 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.20648	-118.57991	**fee expedite per applicant**New rooftop solar system on SFD, 11.4 kW AC / 12.3 kW DC (STC). (41) modules, (41) P320 optimizers, (1) 11.4kW central inverter, system interconnect at 200A rated MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51341	12041-10000-20227	22220 S DENKER AVE	90501	15	048B193   669	7346021014	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	33.82499	-118.30355	INSTALLATION OF ROOF-MOUNTED 3.3KW PHOTOVOLTAIC SYYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51342	12041-10000-30629	5105 E YORK BLVD	90042	14	156A225   289	5478001016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.12115	-118.20447	TENANT IMPROVEMENT INSIDE A DONUT SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51343	14041-10001-00837	8850 N TAMPA AVE #104	91324	12	195B117   410	2784003072	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM	ADDRESS	34.23108	-118.55333	permit already on original. 1 story (Q&Q Hawaiian BBQ) Plan check only per inspector request for T24 energy plan check. bldg # 13016-30. 24932: RESTAURANT T.I.  - INSTALL LIGHTS, SWITCHES AND OUTLETS UNDER EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51344	17041-20002-45171	19600 W PLUMMER ST #400	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM			PC Approved	04/02/2018 12:00:00 AM	ADDRESS	34.2426	-118.5602	4/2/18changes to an approved set of plans. changes noted delta 3.  changes to include revised lighting and energy calculations.  this is plan check only.    (((1/30/2018first time tenant plan check for power.  energy has been approved under master application.  permit fees paid under 17041-20000-45171.  this is plan check only.))) (((PLANCHECK FOR T24 ENERGY. CONVERT (E) RETAIL TO (N) BANK (2421 SF). BUILDING PERMIT # 17016-10000-34865)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51345	17041-10000-08408	525 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05109	-118.25696	Plan check for Title 24 only in existing high-rise building T.I. coffee shop. Total area: 320 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51346	19041-10000-50184	1195 S MUIRFIELD ROAD	90019	10	129B185   277	5083011012	R2-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.05238	-118.33344	NW PV1 ROOFTOP SOLAR SYSTEM CONSIST OF 14 MODULES (TRINA TSM-305), 14 OPTIMIZERS (SE320) AND 1 CENTRAL INVERTER (SE3800H-US). SYSTEM SIZE IS 4.27KWDC AND 3.8 KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51347	13041-10001-32944	9329 N VALJEAN AVE	91343	12	198B137   425	2676008004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.24018	-118.48736	Expedited RSES plan check per applicant request.[][]PV1, Install 5.25 kw DC roof-mounted solar array for a one story house, interconnect with the main service panel. Transformerless inverter:SolarEdge SE5000A-US. 21 modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51348	18041-30000-43883	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			Verifications in Progress	12/14/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC FOR RETAIL TI FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA 652 SQ.FT SCOPE INCLUDES NEW PANEL, CIRUCITS AND LIGHTS. B#18016-30000-36916	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51349	13041-20000-17197	10351 W WILSHIRE BLVD 1-17	90024	5	135B157   100	4359016***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Expired	08/03/2015 12:00:00 AM	ADDRESS	34.0676	-118.42801	FIRE ALARM SYSTEM. REPLACE CONTROL PANEL WITH NEW. NEW DEVICES TO BE ADDED AND REPLACEMENT DEVICES CHARGED AS NEW. TOTAL OF 196 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51350	19041-20000-16403	7221 N HYANNIS DR	91307	12	183B093    51	2027012012	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.20137	-118.64149	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 14.8KW DC/11.4KW AC. SCOPE OF WORK INCLUDES (37) LG400N2W-A5 PV MODULES WITH P400 OPTIMIZERS, AND A SE11400 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51351	15041-20000-37012	15962 W NORDHOFF ST	91343	12	198B141   698	2672005031	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.23544	-118.48043	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (34) modules. Standard plan is being used.(34)modules-KYOCERA #KU2656ZPA(1)inverter-FRONIUS #PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51352	17041-20000-09774	12765 W VAN NUYS BLVD	91331	7	210B161    74	2533019032	[T][Q]C2-1VL-CDO-CUGU, [T][Q]P-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.27525	-118.41242	Remove recessed under canopy fixtures (fluorescent T12s) and replace with same quantity LED fixtures.  Plan check for energy.  Building permit filed under 17016-20000-02598	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51353	13041-10000-33912	1111 W WILSHIRE BLVD 102	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	05/02/2014 12:00:00 AM	ADDRESS	34.05259	-118.26348	Plan check for power and energy and T24 for a first time tenant retail store. Total area 1496 sq ft. New 400 A  Gutter.(Review by Mr. Frncis)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51354	18041-20000-33213	2424 E OLYMPIC BLVD	90021	14	121-5A217 390	5168002800	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM			Reviewed by Supervisor	09/05/2018 12:00:00 AM	ADDRESS	34.02545	-118.22917	Installation of grinder system and 75 HP compressor at (E) waste management facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51355	16041-10003-40751	1120 W WASHINGTON BLVD	90007	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.03867	-118.28211	DELTA 6 CHANGES TO APPROVED PLANS, B# 16010-10000-03993.***PC FOR POWER AND ENERGY FOR  NEW 9 STORY PARKING STRUCTURE. PC FOR NEW 1000 A SERVICE. TOTAL AREA IS 170703 SQFT. NEW KPARKING STRUCTURE (NINE TIERS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51356	17041-20000-06662			4	150B177   457	5551012025	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			Reviewed by Supervisor	04/11/2017 12:00:00 AM	PIN	34.10423808	-118.3578326	Plan check for power only. Project site is a new 2-story accessory living quarters.Note 1: Building permit has been issued under 14010-30000-04160Note 2: There is a 2-story single-family home with a habitable basement that has been included as part of this electrical plan check. A separate electrical application has been created under 17041-20000-06657 with building application number 14010-30000-04159.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51357	12041-10000-23687	1110 S WESTERN AVE	90006	10	129B193   694	5080010002	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.05041	-118.30886	NEW 2-STORIES SHOPPING CENETR WITH SUBTERRANEAN PARKING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51358	13041-10000-10822	8610 W 3RD ST	90048	5	138B169   567	4334009018	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/26/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.07333	-118.37996	TI FOR EXISTING OFFICE SPACE. NEW FIXTURES. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 1182 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51359	13041-10000-34488	6320 N TOPANGA CANYON BLVD BLD # G	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.18578	-118.60536	PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING G.BUILDING PERMIT # 13010-10000-02910.New  retail  bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51360	15041-20000-03277	23031 W SYLVAN ST	91367	3	177B097    93	2039011003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.18476	-118.62891	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. ADDITION TO EXISTING SYSTEM SIZE: 3.5 KW .  TOTAL SYSTEM SIZE: 8KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51361	19041-10000-41261	2049 S CENTURY PARK EAST STE 400	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Energy pc only for 4th floor of high rise building. area of scope 22825sf.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51362	17041-20000-22107	18133 W VENTURA BLVD A	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	ti to an existing commercial space.  first time tenant.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51363	18041-10000-12413	16931 W SHERMAN WAY	91406	6	183B133    25	2227003015	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.20137	-118.50217	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51364	16041-20000-15071	13055-13057 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.18915	-118.4171	PLANCHECK FOR T24 ENERGY.  INTERIOR ALTERATION OF EXISTING RETAIL SPACES.  VICTORY PLAZA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51365	19041-10000-14313	18301 W NAPA ST	91325	12	192B125   928	2786003037	M1-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Issued	04/19/2019 12:00:00 AM	ADDRESS	34.22658	-118.5317	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51366	16041-10001-29920	901 E NEW DOCK ST	90731	15	024B209   295	7440020908	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM			Corrections Issued	05/05/2018 12:00:00 AM	ADDRESS	33.7552	-118.25713	SUPPLEMENTAL FOR LOST SET OF PLANS  -  RE PLAN CHECK PC FOR 2400V CABLE TO CRANE CONNECTION. CRANE POWER WILL PICK UP AT THIS LOCATION. CHECKING FOR SHORT CIRCUITS AND LOADING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51367	14041-20000-06173	4320 N VAN NUYS BLVD	91403	4	166-5A151 234	2266006051	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Apartment			03/06/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.14953	-118.44884	PV2 ROOFTOP FOR EXISTING APARTMENT BUILDIND. TOTAL SYSTEM SIZE 34.2KWAC. ZERO FEES DUE TO SENATE BILL NO 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51368	19041-10000-34126	838 S BEACON AVE	90017	1	130-5A205 187	5142017022	R3-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	11/07/2020 12:00:00 AM	ADDRESS	34.05175	-118.27387	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51369	13041-10001-35614	12005 W BLUFF CREEK DR	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	33.98179	-118.40283	((10/28/2014 - Sup. application for changes to approved set.  Removing some lighting fixtures and change of service from overhead to underground))PLANCHECK FOR POWER AND ENERGY. CORE AND SHELL. NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY 29895 SF WITH NEW SURFACE PARKING LOT1 OF 2. BUILDING 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51370	12041-20000-29581	7400 N VAN NUYS BLVD # 109	91405	6	186B149   448	2215026048	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			12/07/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.20519	-118.44847	T-24 lighting plan check for remodeled reatil space.  Due to fire damage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51371	18041-10000-44212	4120 W PICO BLVD	90019	10	129B189   969	5072006026	C4-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	11/11/2020 12:00:00 AM		Permit Finaled	11/17/2020 12:00:00 AM	ADDRESS	34.04753	-118.32541	CHANGE OF USE FROM RETAIL/MEDICAL OFFICE TO CHURCH-FELLOWSHIP HALL W/ ACCESSORY BIBLE STUDY AREA.SERVICE AND PANEL BOARDS ARE EXISTING; FULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51372	13041-20000-31154	5949 N VAN NUYS BLVD	91411	4	177A151   145	2244001030	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	PIN	34.17890191	-118.44917219	"PV2 (1) 500KW INVERTER 1284 MODULES AND 13 COMBINER BOXES"" $0 PERMIT FEE IS DUE TO THE 2012 SENATE BILL NO. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51373	12041-20000-16248	19300 W RINALDI ST	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM			PC Approved	07/13/2012 12:00:00 AM	ADDRESS	34.27414	-118.55457	Install new exterior light and signage.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51374	14041-20001-29534	17141 W TRIBUNE ST	91344	12	207B133    85	2696023028	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.26736	-118.50684	11/18/2014 - Modification to approved set. Add AC disconnect on detached garage, update single line diagram and roof plan to reflect change. Delta 1 changes.[PV1INSTALL ROOF MOUNTED PV STSREM SIZED 4.0KW INTERCONNECTED WITH MSP.(16) SOLARWORLD SW 275 MODULES(16) ENPHASE M250 MICROINVERTERS]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51375	11041-10000-13921	12424 W WILSHIRE BLVD	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM			PC Approved	07/06/2011 12:00:00 AM	ADDRESS	34.04135	-118.47058	TI TO AN EXISTING OFFICE BUILDING, ON THE 8TH FLOOR.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51376	18041-10002-07688	7540 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			Corrections Issued	05/04/2019 12:00:00 AM	ADDRESS	33.94052	-118.42863	"DELTA CHANGES TO APPROVED PLANS FOR INSTALLING ""K"" KEY SWITCHES. (PER MZ)<<<PC for powery for LAX delta airlines high bay hangar with one story of office space. Installing new 3000A service, new service quipment, new panels and circuits.    Title 24 and lighthing is under a separate permit MZandi  . B# 18010-10000-00614.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51377	18041-20000-47315	7020 N RESEDA BLVD	91335	3	183B125   506	2125006016	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.19813	-118.53588	Plan check for Title 24 only in existing space T.I. Office. Total area: 4113 sq ft. B#18016-10000-10266	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51378	17041-20001-07282	13236 W AETNA ST	91401	2	177B157   783	2331029013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM			PC Approved	03/13/2017 12:00:00 AM	ADDRESS	34.18021	-118.42153	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP.Derating main breaker to 175A. 9.84kW ungrounded system. (41) EnPhase M250 microinverters. (41) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51379	13041-10000-16956	7301 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.94207	-118.423	Plan check power and energy. Intallation for new outdoor lighting for Administration Building West Employee Parking Lot. Site located in Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51380	17041-20000-19348	10635 W WILSHIRE BLVD	90024	5	132B153    69	4360011003	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			06/08/2017 12:00:00 AM			Reviewed by Supervisor	07/12/2017 12:00:00 AM	ADDRESS	34.06138	-118.43484	Renovation of (E) 45-unit apartment building to repair water and fire damaged areas.  15 residential units to be rewired.  New 208Y/120V 3 phase 2000A service.  Building permit application under 17016-10000-08840.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51381	14041-20000-09118	20953 W OSBORNE ST	91304	3	195B109    47	2779001030	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM			PC Info Complete	07/24/2014 12:00:00 AM	ADDRESS	34.23315	-118.59033	New 800A service and new lighting for existing building.  Plan check for power and energy.Note: Additional plan check fee need to be paid as submittal #2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51382	19041-20000-38830	18735 W LISBURN PL	91326	12	219B121   169	2870002012	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.29516	-118.54203	PV1. INSTALL 11.34 KW AC PV SYSTEM WITH (36) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE10000H). SCOPE OF WORK INCLUDES (3) NEW TESLA ENERGY STORAGE BATTERIES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51383	19041-20001-29072	2604 S MIDVALE AVE	90064	5	123B157   190	4256031023	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.03605	-118.42633	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET. CHANGES MADE TO SITE PLAN, SINGLE LINE, ELEVATIONS, AND PLOT PLAN. ADDING MORE DISCONNECTS TO THOSE PAGES. CLOUDED DELTA    A     CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51384	16041-20002-11761	11011 W OTSEGO ST	91601	2	171B173   834	2353007033	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			05/31/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.16308	-118.37103	SUPPLEMENTAL PLAN CHECK, CHANGES TO APPROVED SET, CLOUDED DELTA C CHANGES ONLY. ADDITION OF LOADS TO PANEL HBB, CHANGE TO SERVICE LOAD CALC, CHANGE TO MSA PANEL SCHEDULE, AND MINOR CHANGE TO POWER FLOOR PLAN(((Change to approved set by adding (2) new panel and new ckts on the floor plan. All changes under delta-B.)))(((Plan check for power and energy. Project site is a new 144-unit, 5-story apartment building over 2 levels of basement parking. Work includes a 3,000-amp service. Total lighting area = 122,863 sq. ft.Note: Building application has been created under 15010-20000-04055)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51385	11041-10000-21306	12218 N BROOKMONT AVE	91342	7	219B145   704	2611040006	RA-1	North Valley	Sylmar	Sylmar	YES	1066.05	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2011 12:00:00 AM	11/03/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	34.29327	-118.46385	New rooftop PV system for a single family residence.  Plan check for POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51386	19041-10000-22968	3420 N BLAIR DR	90068	4	159B181    84	5579010013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	06/28/2021 12:00:00 AM	ADDRESS	34.13469	-118.34563	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15  MODULES (PHONO SOLAR PS325M-24 AND 15 MICROINVERTERS (IQ7-60). SYSTEM SIZE IS 4.875KWdc AND 3.75KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51387	17041-20000-36796	333 S HOPE ST 27TH FLR-2ND PHASE	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. 4440 SQFT. PHASE 2 OF 2BUILDING PERMIT # 17016-10000-29724	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51388	16041-30001-18169	8621 S CIMARRON ST	90047	8	097-5A191 328	6036001006	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	33.95925	-118.31623	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (14) modules, (1) combiner box and (1) inverter. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51389	15041-10000-30430	503 S MAIN ST	90013	14	129A211   155	5149037010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM			PC Info Complete	09/15/2015 12:00:00 AM	ADDRESS	34.04665	-118.24887	Energy plan check for a grocery store. Scope includes new lighting, receptacles and equipment; total area is 2030-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51390	15041-10000-30082	6430 W SUNSET BLVD Ste 1220	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.09782	-118.32979	PC FOR ENERGY ONLY. T.I FOR OFFICE SPACES IN COMMERCIAL BUILDING. TOTAL AREA 1540 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51391	13041-20000-06957	823 N ORANGE GROVE AVE PV-1	90046	5	141B177   151	5527002020	R2-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.08614	-118.36063	PV-1. Microinverter standard plan. 4.3kW total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51392	18041-20000-07331	5021 N MONTEZUMA ST	90042	1	151-5A225  85	5469009039	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	34.11089	-118.20564	PLAN CHECK FOR A BATTERY BACKUP SYSTEM ON EXISTING PV SYSTEM - SYSTEM CONSIST OF NEW TESLA POWERWALL (14KWH) AND EXISTING 7.02KVA SOLAR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51393	18041-10000-20690	421 S BIXEL ST	90017	1	132A207   163	5152003001	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Issued	06/05/2018 12:00:00 AM	ADDRESS	34.05622	-118.26088	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51394	14041-10000-25886	4121 N EAGLE ROCK BLVD	90065	14	156A219   137	5473006006	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Apartment			09/19/2014 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.12142	-118.22666	Plan check for power and energy. Total area = 12500 sq. ft. New 4 story apartment building. Fire alarm variance.Building # - 14010-10000-02920	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51395	14041-10000-13415	15140 W BLEDSOE ST STE A	91342	7	222B145   103	2506002029	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.30714	-118.46302	T24, Remove HID light fixtures and replace with new fluorescent fixtures. Total area 7445 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51396	12041-20000-07408	15150 W SUNSET BLVD	90272	11	129B129  1012	4411001016	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM			PC Approved	03/30/2012 12:00:00 AM	ADDRESS	34.0458	-118.52423	Plan check for lighting compliance (900 sq. ft.).(INTERIOR ONLY T.I. OF 900 SQ FT PHARMACY SALES AREA INC. NEW STAIRS & RAMP HANDRAIL.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51397	12041-20000-02235	78 S BEVERLY PARK LANE	90210	5	156B161    69	4386008018	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2012 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.12303	-118.4152	Replace existing 600 ampere 3 phase service with new 1000 ampere 3 phase service.  reconnect existing subpanel feeders  and existing branch circuits to the new distribution board, and add to new 50 ampere single phase feeders for party receptacles, all other loads indicated on the load schedule are future.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51398	18041-10000-48271	400 S BROADWAY	90013	14	129A211   293	5149024118	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			12/20/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.04925	-118.24934	Fire plan check for a new high rise apartment building (35-story) with (2) Fire alarm panel, (23) control panels and (1806) fire alram devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51399	15041-30000-39803	8721 S METTLER ST	90003	9	096A207    50	6041018018	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			PC Approved	11/24/2015 12:00:00 AM	ADDRESS	33.95859	-118.26673	Title 24 plan check only.  Total area = 16,340 sq. ft.     T.I. to storage and light manufacturing building.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51400	14041-20000-19834	6315 N CREBS AVE	91335	3	177B121    63	2127022008	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.1853	-118.54388	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MAIN SERVICE PANEL.(33) TRINA SOLAR TSM-255 MODULES(1) SOLAREDGE SE6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51401	10041-10000-19062	16847 W VENTURA BLVD	91436	5	168B133    86	2259010001	C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	01/31/2011 12:00:00 AM		Permit Finaled	04/08/2011 12:00:00 AM	ADDRESS	34.15927	-118.50037	Small ti work for a grocery store. and title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51402	16041-10000-18162	12901 W CORAL TREE PL	90066	11	102B157    26	4211009005	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.97791	-118.42275	Title 24 plan check only.  Backroom at request of applicant.  Total area = 22,500 sq. ft.  Total load = 213 A @ 480 V (365 A @ nominal voltage)Renovation of existing school building including new lighting and plug loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51403	12041-10000-25116	165 S LA BREA AVE	90036	5	138B181  1156	5513019038	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			10/19/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.07174	-118.34423	IN AN EXISTING RETAIL STORE, NEW CIRCUITS AND LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51404	19041-10000-25924	13566 W HART ST	91405	2	183B157   514	2328010049	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Issued	07/08/2019 12:00:00 AM	ADDRESS	34.19744	-118.42912	PV1. Install 6.27kWdc AND 6KWac roof mounted grid tied PV system. (22) modules with (22) P320 OPTIMIZERS, (1) 6 KW (SE6000H-US) rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51405	15041-20000-24482	1055 W 7TH ST 19th Floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.0507	-118.26334	TI to existing high rise commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft 7,744	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51406	12041-10000-13218	680 N CHAUTAUQUA BLVD	90272	11	126B129   561	4411016002	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.04065	-118.51798	New single family residence with a 600Amp service.  Full Plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51407	13041-20000-21423	16936 W VOSE ST	91406	6	183B133   438	2227031007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Expired	09/02/2015 12:00:00 AM	ADDRESS	34.19855	-118.50264	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 1.47 KW. 6 MODULES AND 1 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51408	18041-20001-19734	16152 W COVELLO ST	91406	6	186B137    96	2205022015	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM			PC Approved	10/03/2018 12:00:00 AM	ADDRESS	34.20741	-118.48542	PV2.  Install 16.32 kW DC roof mounted grid tied PV system.  (108) modules with 15 and 20 kW rated string inverters.  2 systems with different service interconnections.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51409	17041-10000-21813	20133 W SATICOY ST	91306	3	186B113   120	2114004045	(Q)C1.5-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.20848	-118.57211	PC FOR T24 ENERGY ONLY FOR FIRE DAMAGE REPAIR. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51410	14041-20000-24827	7006 S HOOVER ST UNIT 1	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #1.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51411	13041-10001-33090	12942 W WENTWORTH ST	91331	6	195B161   152	2628010021	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.23456	-118.41447	][]expedited per applicant request ][][PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (N) 200A MAIN IN A 2-STORY HOME. non-standard plan. SYSTEM SIZE IS 5.5 kW DC, & transformerless, with power (22) optimizers (Solaredge #OP250-LV-MC4SM-2NA-Z).  The following components/equipment are used:(22) Trina solar #TSM-250PA05.18(1) Solaredge #SE5000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51412	15041-20000-20081	6236 N LANGDON AVE	91411	6	177B145   231	2242008014	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Expired	08/01/2017 12:00:00 AM	ADDRESS	34.18411	-118.46825	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51413	18041-10000-47412	737 N ORANGE DR	90038	5	141B181   401	5525007024	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.08453	-118.34172	PC FOR PV SYSTEM. SYSTEM SIZE IS 4.225 KW PV ARRAY + 13.5 KHW ENERGY STORAGE SYSTEM. 13 PV MODULES (SOLAR CITY SC325) W/SOLAREDGE OPTIMIZER. INVERTER MODEL (SE3800H-US000SNU2). ENERGY STORAGE SYSTEM MODEL (TESLA POWER WALL-120/240V)14KHW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51414	19041-10000-52610	21754 W VINTAGE ST	91311	12	204B105   763	2747020036	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.25204	-118.60359	NEW PV1 ROOF MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 9.12KW DC / 7.6KW AC (CEC VALUE 8.28 KW), 32 MODULES (285W),  1 CENTRAL INVERTER (SE7600H),  32 POWER OPTIMIZERS (P320),  AND EXISTING MAIN SERVICE PANEL RATED FOR 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51415	17041-20000-35089	10106 W TOLUCA LAKE AVE	91602	4	165B181   355	2424031015	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.14844	-118.35008	Installation of 40.5 kWh energy storage system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51416	12041-20001-09704	11900 W COURTLEIGH DR	90066	11	111B161  1000	4233019020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			05/09/2013 12:00:00 AM			PC Approved	05/09/2013 12:00:00 AM	ADDRESS	33.99718	-118.41875	"Modification to approved set of plans to change feeder size to ""28 MULTI-METER BANK"".  Plan check only for ""DELTA 3"" feeder change only.               <<<<<New 28 unit apartment building. Fire alarm variance was file. Plan check for power and energy, the building is 5 levels.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51417	14041-20000-07429	645 W 9TH ST	90017	14	129A207   330	5144027***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	PIN	34.04579989	-118.26058615	T.I. to existing Raphs supermarket.  Install new subpanel and branch circuit.  Install indoor lighting less than 50 percent within the enclosed area.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51418	19041-10000-52568	9930 N HANNA AVE	91311	12	201B101    62	2745004017	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Issued	12/19/2019 12:00:00 AM	ADDRESS	34.25088	-118.60733	PC FOR A NEW PV SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE 10.23KWdc / 9.45KWac.(31)MODULES- PANASONIC 300 MODULES(VBHN330SA16)(31) SOLAR EDGE P400(1)INVERTER-SOLAREDGE P400	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51419	14041-20001-22482	18325 W KINGSBURY ST	91326	12	207B125   378	2731003011	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM			PC Approved	08/27/2014 12:00:00 AM	ADDRESS	34.26283	-118.53266	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(18) SUNPOWER SPR-327NE MODULE(1) POWER ONE PVI-6000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51420	12041-10000-15435	341 S 6TH AVE	90291	11	111B145  1128	4240010015	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Expired	09/04/2014 12:00:00 AM	ADDRESS	33.99811	-118.47126	PV system for single family dwelling. 5.348kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51421	19041-10000-51262	11224 N ALTA AVE Lot 10	91345	7	210B145   523	2664007***	P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	02/14/2020 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.27426	-118.46889	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION, SYSTEM SIZE IS 4.095 KW DC;  3.8 KW AC. SYSTEM INCLUDES  INCLUDES 13 MODULES (HANWHA Q.PEAK BLK-G5 315), 13 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51422	15041-10000-01386	9025 N BALBOA BLVD	91325	12	198B133   654	2690006018	(Q)C2-1VL	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.23537	-118.50282	Plan check for T-24 only. Out side lighting. Total outside area: 16020SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51423	18041-10000-17079	5517 W VENICE BLVD 1ST FLR	90019	10	126B177   253	5069027007	C2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM			PC Approved	05/21/2018 12:00:00 AM	ADDRESS	34.04421	-118.3591	PC  FOR TITLE 24 ENERGY ONLY  FOR CHANGE OF USE OF EXISTING  FIRST FLOOR RETAIL SALES TO PRE-SCHOOL ( NURSERY ) OCC. LOAD= 48SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES TOTAL AFFECTED AREA 1027 SQ.FT. THIS IS PLAN CHECK ONLY.  PERMIT UNDER 18041-10000-17099  ((B#17016-20000-30239))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51424	18041-10000-03402	7415 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.2052	-118.49233	REPLACE INDOOR AND OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51425	16041-20000-42427	12385 N SAN FERNANDO ROAD #40	91342	7	219B149   648	2611007050	(T)(Q)RAS3-1-CPIO, C2-2D-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.29518	-118.45448	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51426	17041-10001-25554	350 E 1ST ST	90012	14	129A215   347	5161017022	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.04935	-118.23978	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE REDUCTION OF LIGHTING SCOPE. DINING AREA TO REMAIN. LIGHTING REMODEL IN CASHIER AREA. NO OTHER CHANGES NOTED. UPDATED TITLE T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51427	11041-10001-07792	401 W CENTER WAY	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM	06/28/2011 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	33.93790872	-118.42837934	due to DWP'S DELAY, CONSTRUCTION TRAILERS ARE TO BE TEMPORARILY SUPPLIED FROM 500kw GENSET AND FFEDERS REPLACED WITH TYPE W CABLES IN ACCORDANCE WITH ARTICLE 400OF THE NEC.(((((((((((((((TEMPORARY POWER AT LAX FOR CONSTRUCTION TRAILERS. 5000A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51428	16041-20000-25433	10539 W CROCKETT ST	91352	6	192B177   732	2407002019	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM				PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.4 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51429	11041-10000-11625	673 S SHATTO PL	90005	10	132B197   106	5077010009	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Apartment			06/10/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.06087	-118.29045	EXISTING 39 UNIT APARTMENT COMPLEX, 4-STORY.  NEW SERVICE, ALL NEW PANELS FOR THE UNITS, OUTLETS, AND ELECTRICAL HEATERS.  PLAN CHECK FOR POWER.  (PLAN CHECKER TO VERIFY # OF NEW CIRCUITS VS EXISTING)  Electric resistance space heating was approved for the building by Mechanical Plan Check on application number  11044-10000-08788.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51430	16041-10000-08316	801 S HOPE ST UNIT B	90017	14	129A209   268	5144020200	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.04656	-118.25938	FIRST TENANT IN COMMERCIAL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51431	13041-10000-09562	22254 W COHASSET ST	91303	3	186B101   401	2023021016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.2065	-118.61226	INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 5.39 kW. INVERTER: SUNNY BOY 5000-US, 22 MODULES; TSM-245 PA05.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51432	12041-10000-14006	709 S OLIVE ST #A, #B, #D	90014	14	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM			PC Approved	06/18/2012 12:00:00 AM	ADDRESS	34.04642	-118.25602	"Plan Check only for Power and Energy.  New lighting and circuits, all panels are existing.  (((Plans are originally submitted as First time tenant per applicant to a retail space for a full plan check.   Plans are resubmitted as an existing retail space per contractor.)))  Permit Fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51433	18041-10000-47735	13448 W BEACH AVE	90292	11	108B153  1002	4230004039	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	01/13/2021 12:00:00 AM	ADDRESS	33.99058	-118.44547	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES (483) FA DEVICES, (1) FIRE ALARM PANEL  (1) COMMUNICATION PANEL AND (4) POWER SUPPLIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51434	10041-10000-08414	10654 N BALBOA BLVD	91344	12	207B133   586	2684001023	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	07/12/2010 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.26387	-118.50206	Ti in a church. New AC units, Panel, branch circuits, and lights. Plan check for Power and Energy.  Emergency lighting is provided by ETL listed emergency lights with 90 min bat backup.  Photometrix calculation is provided on E6 A.  Load calculation is based on the peak DWP month data on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51435	19041-10000-31833	5976 W 79TH ST	90045	11	099B169   894	4107012017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	33.96602	-118.38777	NEW PV-1 ROOF MOUNTED 6.4 KW (DC) PV SYSTEM WITH 20 PV MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51436	14041-10000-15861	115 E PICO BLVD	90015	14	124-5A209  76	5139027013	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.03612	-118.25976	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 6152 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51437	15041-20000-12230	930 N VISTA ST	90046	5	144B181   722	5531025006	R1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.08795	-118.35207	Plan check for PV roof mounted 5Kw system 13 modules and 1 inverter(SMA SB5000TL US 22) with existing main panel. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51438	10041-30000-10466	5550 N TOPANGA CANYON BLVD Suite 100	91367	3	174B101   285	2146007119	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM			Not Ready to Issue	06/03/2010 12:00:00 AM	ADDRESS	34.17162	-118.60554	Installing lighting and power for office spaces. This p/c is for tilte 24 energy only.  Existing permit 10041-90000-09232.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51439	14041-20000-22939	20615 W LONDELIUS ST	91306	3	195B109   218	2780012019	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.2292	-118.58245	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP, system size: 4.2kW.(22) Kyocera TSM-255 pv modules(1) ABB PVI-4.2-OUTD-S-US-Z-A transformerless inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51440	19041-10000-35060	4645 W MARWOOD DR	90065	14	159A219   112	5684027025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.13084	-118.22433	$0.00 FEE UNDER INSPECTION DUE TO SENATE BILL 1222, 1414[EPLAN] CHANGES TO APPROVE SET TO REMOVE SOLAR METER CHAGES HAVE BEEN CLOUDED  ORIGINAL PERMIT Solar permit number is 19041-10000-27450	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51441	17041-10000-36822	3201 N LACY ST	90031	1	142-5A221 279	5205002902	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Public Safety Only			10/12/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	10/26/2020 12:00:00 AM	ADDRESS	34.08349	-118.21854	NEW FIRE WARNING SYSTEM FOR A ANIMAL SERVICES CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51442	16041-10002-01907	1830 W SLAUSON AVE Store 1039	90047	8	105B193  1872	6001001023	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	33.98779	-118.31204	Checking for DELTA 7 .Revisions include change to main service per AS BUILT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51443	18041-20001-30825	18460 W ROSCOE BLVD	91325	12	192B125   934	2102001018	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM			PC Approved	04/04/2019 12:00:00 AM	ADDRESS	34.22046	-118.53569	4/4/2019changes to an approved set of plans.  changes noted delta 2.  changes to the looby floor lighitng. New energy calculations and lighting layout.  this is plan check only.  ((((Plan check for Title 24 only. Project site is a 1st floor corridor of an existing commercial building. Project scope is an interior remodel. Total lighting area = 1,281 sq. ft.Note: Building application has been generated under 18016-20000-26164))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51444	18041-10000-26198	2434 N BIRKDALE ST	90031	13	144B213   151	5445003036	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Apartment			07/13/2018 12:00:00 AM			PC Info Complete	04/22/2021 12:00:00 AM	ADDRESS	34.09353	-118.2375	PC FOR NEW (N) 37 UNIT RESIDENTIAL APARTMENT BUILDING (N)NEW SERVICE RATED 2000A 3PH 120/208VSCOPE INLCLUDES NEW EQUIPMENT PANELS AND CIRCUITS.TOTAL AFFECTED AREA 89470 SQ.FT. B#18010-10000-02914	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51445	16041-10000-22232	145 S FAIRFAX AVE 4th Fl.-#400&403	90036	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.07288	-118.36166	PC for T-24 only. T.I.  on (E) commercial build. 7730 sq.ft. Install new lights and receptacles. New addition load < 400A.B# 16016-10000-14059	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51446	18041-20000-03780	601 N HANLEY WAY	90049	11	135B137    85	4494019030	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	34.06965	-118.48715	Plan check for power only. Project site is a new 2-story single-family dwelling with a basement.Note: Building permit has been issued under 16010-30000-03729, which has electrical permit fees included.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51447	18041-10000-38212	750 S LAMAR ST INBOUND-PORTAL	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (E) INBOUND PORTAL5 OF 10BUILDING PERMIT 13010-10000-00549	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51448	13041-20000-32762	940 S LA BREA AVE	90036	4	132B181   647	5084004008	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.05772	-118.34559	T24 FOR EXISTING RETAIL SHOP. CREATING NEW CLASSROOM WITHIN BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51449	14041-10001-26096			1	129B193  1466	5075011001	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	PIN	34.04605019	-118.30232539	Changes apply to approved set, all changes including removing indoor  auto timer and replacing with  occupancy sensors ,outdoor lighting also added to the plan. ((( PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 795 SQFT.  2008 T24 COMPLIANCE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51450	11041-20000-20246	13253 W VICTORY BLVD	91401	2	180B157   920	2326025023	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.18682	-118.42197	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51451	14041-10000-12030	1149 S HILL ST	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.03926	-118.26099	permit to be pulled at EPC counter only. Plan check for energy only. Emergency lighting in a highrise building. Less than 400A per applicant but other work is being done in the building under separate projects. BLDG#14016-10-08033: PROPOSED T.I. NON-BEARING PARTITIAL ACOUSTIAL CEILING AT CORRIDOR AREA ONLY.  OCCUPANY GROUP B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51452	18041-10001-32903	7007 W ROMAINE ST	90038	4	144B181   604	5532030011	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.08901	-118.34188	Changes to an approved set of plans. Scope of work includes revision of lighting, circuits and single line layout. Note changes under delta 6,7,8. Original plan checker is Esteban Claro. FULL PC FOR A FIRST TIME OFFICE TI. SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS TO AN EXISTING MAIN DISTRIBUTION BOARD. TOTAL SQ. FT. 17349.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51453	12041-10000-18538	10801 N SAN FERNANDO ROAD BLDG A	91331	7	207B157   342	2619017030	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.26635	-118.42259	"BUILDING ""A"".  RESTORATION OF BUILDING TO SUBDIVIDE INTO 3 SMALLER BUILDINGS. CHANGE OF USE FROM RETAIL TO RESTAURANT FOR PORTION OF THE BUILDING.  FULL PLAN CHECK FOR SHELL ONLY IN A METHANE ZONE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51454	14041-20001-35114	6600 N TOPANGA CANYON BLVD #2106A	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM			PC Approved	02/13/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	((2/13/2015))CHANGES TO AN APPROVED SET OF PLANS.  LIGHTING FIXTURES CHANGED NOTED DELTA 2 ON PLANS.  T.I. to a jewelry store on Level 2.  Install branch circuits and lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51455	12041-20000-19035	21255 W BURBANK BLVD Bldg D-6th Floor	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.17432	-118.59446	Remodel 6th floor of the building.  Plan check for power and energy and emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51456	12041-10000-27812	4550 W PICO BLVD C314	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.04842	-118.33486	"TENANT IMPROVEMENT AT THE MIDTOWN GNC STOREPLAN CGHK IS FOR TITLE 24***BEGIN PRINT: 331285 (6/26/13 11:14)Application Number: 12041 - 10000 - 27812Address: 4550 W PICO-----------------------------------------------NO: 114041  -- ElectricalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 06/17/2013 by Inspector GARY LYNCH at phone#(213)252-3089.  CEIS Case Number is 501237.Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.(Created: IMSV7 / 06-10-13)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 114042  -- ElectricalCode Enforcement Bureau has issued an order. This parcel iseligible for issuance of a 30 day time limit permit (includingBuilding, Electrical, HVAC and Plumbing) with a work descriptionas follows. ""COMPLY WITH DEPARTMENT ORDER effective date06/17/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation. Ifadditional assistance is needed, please call Inspector GARY LYNCHat (213)252-3089 of ON-SITE SIGN ENFORCEMENT.  CEIS Case Numberis 501237.(Created: IMSV7 / 06-10-13)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~***END PRINT: 331285 (6/26/13 11:14)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51457	12041-10000-07097	13007 W AETNA ST	91401	2	177B161   739	2331022004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.18043	-118.41609	NEW ROOF MOUNTED 7.92 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51458	14041-10001-09908	10324 N MASON AVE	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.25804	-118.57961	(((6/27/2014- CHANGES MADE TO APPROVED SET. ADDED STORAGE ROOM)))CHANGE OF USE FROM RETAIL TO BANK. PC FOR ENERGY AND EMERGENCY LIGHTING. TENANT IMPROVEMENT FOR A NEW LOGIX CREDIT UNION BANK IN AN EXISTING SINGLE STORY SHOPPING CENTEER. TOTAL AREA 3905 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51459	15041-10000-23531	2930 N MARSH ST	90039	13	150B213   647	5442029010	R2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.10606	-118.24669	PV1STANDARD PLAN SYSTEM SIZE 3.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51460	19041-10002-08009	1661 W 240TH ST	90710	15	042B193   713	7439007033	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM			PC Approved	02/21/2020 12:00:00 AM	ADDRESS	33.80741	-118.3065	void....for fee testing onlyPlan check for a roofmounted 560KW DC / 662KW AC CEC / 725KW DC PV2 system. Scope includes (1836) modules, (918) optimizers,(51) strings, and (5) inverter interconnecting to the service panel. Note:this project is a second phase for the pv system. All service and switchgear is under 1st phase with the application #: 19041-10000-07987	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51461	15041-20000-42589	9019 N SYLMAR AVE	91402	6	195B149   109	2639012007	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.23374	-118.44602	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (34) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51462	16041-20000-04773	8436 W 3RD ST Ste 601	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.07301	-118.37448	Tenant improvement/change of use for medical office in (E) highrise office building.  Plan check for power and energy. suite 601.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51463	16041-10000-11945	10100 W GALAXY WAY	90067	5	132B161   690	4329007***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.05582	-118.41064	T-24, PC FOR ENERGY ONLY. TI TO AN EXISITNG APARTMENT COMPLEX. SCOPE INCLUDES REWIRING EXISTING LIGHTING FIXTURES FOR THE FIRST FLOOR WALK WAY. TOTAL AFFECTED AREA IS 7239 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51464	10041-20000-05965	8614 W BEVERLY BLVD #155	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Closed	11/21/2011 12:00:00 AM	ADDRESS	34.07598	-118.37831	energy plan check mothball space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51465	12041-20000-27080	11310 W SHERMAN WAY BLDG #2	91605	2	183B173   112	2319001006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Info Complete	01/08/2013 12:00:00 AM	PIN	34.19989971	-118.37702755	Plan check for power only. 1600A service upgrade.   Reconnect exiting panels and equipment.  BLDG #2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51466	10041-10002-17254	5300 N LANKERSHIM BLVD	91601	2	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM			PC Approved	04/20/2011 12:00:00 AM	ADDRESS	34.16715	-118.37571	"DELTA 3 & 4 REVISIONS))))))))New occupancy in a commercial area.  New ""24Hour Fitness"".  Plan Check is for Power & Energy."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51467	11041-10000-13340	12001 W CHALON ROAD # 202	90049	11	141B141     5	4429003027	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01, 2623.02	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	08/08/2011 12:00:00 AM	ADDRESS	34.08469	-118.4849	renovation of  classroom  202 in the Humanities Buildingplan chk is for title 24 ; permit fee is in Inspection Fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51468	15041-20001-02619	12492 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	02/01/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	expedite per customer request.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51469	14041-10000-02757	6029 N NEDDY AVE	91367	3	177B089   502	2045004004	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.18066	-118.65271	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.PV1, Install 11.26 kW DC roof-mounted solar array for a residential home, interconnect with existing service panel. (2)Transformerless inverters: POWER-ONE  PV1-6000-TL(52) Modules: ET SOLAR ET-P660250BB	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51470	11041-10000-08901	8001 W MELROSE AVE	90046	5	141B177   545	5527014001	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	08/01/2011 12:00:00 AM	ADDRESS	34.08391	-118.36392	There is no tenant improvement for this space.  Space is tenant lease only.  Any tenant improvement done to the space must be submitted to plan check.  <<<<<<<T.I.  EXISTING RETAIL SPACE.  ADDING NEW LIGHTS TO A SHELL SPACE (OWNER IS PREPARING SPACE FOR FUTURE LEASE).   TITEL 24 PLAN CHECK USING TAILORED METHOD.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51471	15041-10000-00472	1455 N GORDON ST	90028	13	147A189    89	5545013002	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Expired	02/07/2017 12:00:00 AM	ADDRESS	34.09737	-118.32024	Power plan check only.  Installation of new power distribution system for existing commercial office building (property previously vacant).  New 600 A switchgear, 150 KVA transformer, and two subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51472	18041-10003-46954	1550 N RISING GLEN ROAD	90069	4	147B169   342	5561002035	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.10004	-118.38417	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE RELOCATION OF EQUIPMENT AND RELOCATION OF DISCONNECTS. _____________________________________________CHANGES TO AN APPROVED SET OF PLANS. CHANGES IN DESIGN FOR SOLAR MODULES. REPLACING MODULES FROM SOLARCITY STANDARD SC325 TO SC330.NOTE: PERMIT IS PAID UNDER PCIS#18041-10000-46954	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51473	15041-20000-41155	333 S HOPE ST FL 55	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	T.I NON STRUCTURAL PARTITION. PC FOR ENERGY ONLY. TOTAL AREA 1,830 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51474	14041-20002-30506	19500-19600 S VERMONT AVE	90502	15	057B197    21	7351033009	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	33.85326	-118.29031	08/10/2015 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes include the addition of (2) transformers, (5) panels, associated loads, and revised lighting.*****Previous Work Description*****(((6/23/2015- CHANGES MADE TO APPROVED SET. ADDING NEW CIRCUITS AND EXPANDING LUNCH ROOM. RELOCATING IT ROOM. T24 TO BE RE-VERIFIED)))Tenant improvement serving warehouse/office building.  Plan check for power and energy - more than 400A of connected load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51475	11041-10000-01072	2821 E PICO BLVD	90023	14	118-5A221  16	5169009002	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.02039	-118.21949	New fire alarm monitoring system. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51476	15041-10000-38368	1306 N ORANGE DR	90028	4	144B181   106	5548023037	R3-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.09457	-118.34142	Full PC for a newly constructed 12 unit aparment (4 stories). New service: 800 A. Sq ft = 8556	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51477	14041-20001-14484	10050 W CHARDONNAY CT	91352	2	189B181   715	2403010016	[Q]RD6-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2014 12:00:00 AM			PC Approved	08/25/2014 12:00:00 AM	ADDRESS	34.2164	-118.35041	Changes to approved set of plans.  Change of module layout on rooftop. $0 plan check fee due to State Senate Bill SB-1222.  (((PV1.  Install 6.00 kW roof-mounted utility-interactive PV system.  Microinverter standard plan.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51478	17041-10000-42426	725 S FIGUEROA ST 32ND FL.	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR OFFICE TI IN A HIGH RISE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA  2070 SQ.FTB#  17041-20000-33201	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51479	14041-10000-14934	631 N LAS LOMAS AVE	90272	11	129B121   857	4414014024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.04673	-118.53941	PV1, INSTALL 7.39 KW DC ROOF-MOUNTED SOLAR ARRAY ON 0NE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51480	14041-20000-15600	4119 N ST CLAIR AVE	91604	2	165B165  1180	2367013024	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.14539	-118.39994	PV1Install roof-mounted solar array on SFD. System size: 3.8kW.(1) SolarEdge SE3800A-US transformerless inverter(14) ReneSola JC250M-24/Bb pv modules(14) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51481	10041-20000-13766	6269 N VAN NUYS BLVD	91411	6	178-5A151 192	2241012003	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10, 1283.03	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	07/23/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	PIN	34.18430357	-118.44915121	Revison to approved set 10041-20000-05243. No permit pulled.  RESTAURANTE T.I.ENERGY, EMERGENCY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51482	19041-20000-48451	5406 N BURNET AVE	91411	4	172-5A147  67	2250005020	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/21/2019 12:00:00 AM	ADDRESS	34.16874	-118.46271	PV1.  Install 3.685 kW DC roof mounted PV system.  (11) modules with (6) 720W microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51483	15041-20001-18914	10933 W ROCHESTER AVE SYSTEM 1	90024	5	132B153   743	4324005087	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.05602	-118.4436	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 44 KW. (160) 310W MODULES(4) SMA SB11000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51484	14041-10000-23202	1954 N HILLHURST AVE	90027	4	150B201   744	5590010014	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.10698	-118.28724	CHANGE OF USE FROM RETAIL TO RESTAURANT. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51485	19041-20000-17363	4877 W 63RD ST	90056	11	105B177   449	4002002012	R1-1XL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	33.98217	-118.36389	PV1.  Install 9.76 kW roof mounted grid-tied PV system.  (32) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51486	18041-10000-24214	1002-1004 N HUDSON AVE #1-5	90038	13	144B185   953	5533013016	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			06/28/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.08908	-118.33194	PC FOR POWER FOR A NEW 4 STORY 5 UNIT APARTMENT BUILDING WITH NEW ROOF DECK. SCOPE INCLUDES A NEW 800A 120/240V 1 SINGLE PHASE  3WIRE SERVICE/DISTRIBUTION BOARD, NEW CIRCUITS, AND NEW LIGHTS. B#15010-20000-03333	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51487	15041-10000-43204	741 S BERENDO ST	90005	10	132B197   333	5094009016	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			12/22/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.05866	-118.29429	PV2, ROOF MOUNTED SOLAR SYSTEM TO A TENANT IN AN APARTMENT BUILDING.  (8) MODULES AND (1) CENTRAL INVERTER-3KW-AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51488	12041-10000-27431	6619 W BARTON AVE LOT E	90038	4	144B185  1076	5532014039	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.08781	-118.33594	LOT E POWER AND ENERGY FOR A NEW PARKING STRUCTURE. METHANE ZONE WITH NO UNDERGROUND WORK. 6 CAR CHARGERS iN SITE, 2 OF THEM ARE IN THE SCOPE OF THIS PROJECT. REMAINING CAR CHARGERS TO BE INSTALLED IN LOT D (PER GREEN BUILDING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51489	18041-30000-01671	3222 W SLAUSON AVE	90043	8	108B185   910	4005005028	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	33.98885	-118.32898	Plan check for power and energy for Change of use from retail to Assembly Occupancy. Total area: 9,643 sq ft. 18016-40000-00960	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51490	17041-10000-04622	20059 W RINALDI ST BLDG C1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.2756	-118.57118	PC FOR POWER AND ENERGY FOR A CORE AND SHELL BUILDING(C1). SCOPE INCLUDES A NEW 1200A 277/480 3 PHASE 4 WIRE SERVICE, AND NEW EXTERIOR LIGHTS. TOTA AFFECTED AREA IS  2756 SQ FT. B# 16010-10000-06138	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51491	19041-10000-26192	545 S SERRANO AVE	90020	10	135B193   821	5503020008	R4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Apartment			10/25/2019 12:00:00 AM			Reviewed by Supervisor	12/06/2019 12:00:00 AM	ADDRESS	34.06398	-118.30677	INSTALLING A NEW 1,000 AMP SERVICE, 32 PANLS AND LOADS.(((NEW 5 STORY,  30 UNIT APARTMENT BUILDING OVER 2 LEVELS OF  PARKING.  TYPE IIIA OVER TYPE IA PODIUM AND BASEMENT.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51492	18041-20000-25370	4221 N CLEAR VALLEY DR	91436	5	165B137   318	2284019024	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.14749	-118.48569	PV1.  Install 11.375 kW roof mounted grid tied PV system.  (35) modules with SolarEdge 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51493	13041-20000-21010	13923 W VAN NUYS BLVD	91331	6	204B153   446	2617003034	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.2561	-118.43622	NEW SUBWAY. PLAN CHECK FOR T24 ENERGY ONLY. RENOATION INCLUDES NEW LIGHTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51494	18041-10000-04609	449 N LA BREA AVE	90036	5	141B181  1302	5525028003	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Issued	03/21/2018 12:00:00 AM	ADDRESS	34.07968	-118.34423	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR AND EXTERIOR WORK . TOTAL AFFECTED AREA 12802 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51495	12041-10002-16348	3434 S HOPE ST	90007	9	118-5A203  74	5122021010	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM			Reviewed by Supervisor	03/16/2016 12:00:00 AM	ADDRESS	34.01983	-118.27801	03/09/16Re-plan check for lost set of plans.  NOTE: Permit pulled under PCIS#12041-10000-16348(((((INSTALLATION OF A TELECOM FACILITY INSIDE AN EXISTING PARKING STRUCTURE @ USC CAMPUS.  New 600A Service, panels, circuits, and lightintg.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51496	18041-20001-29500	16644 W DEMARET PL	91344	12	216B137    98	2609010002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM			PC Approved	08/12/2018 12:00:00 AM	ADDRESS	34.29105	-118.49525	expeditepv1install roof mounted pov system sized 10.3 KW AC interconnected with msp.This is an addition to an existing PV system.(45) sunspark modules(45) IQ6 microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51497	12041-10000-26341	123 W ANN ST PV2	90012	1	135A217    35	5409005028	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	34.06552	-118.23177	New 77.2 kw roof mounted PV system for a comercial BLDG. (PV2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51498	16041-10000-19325	1800 E BAY ST	90021	14	123A215    37	5166030011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.03126	-118.23525	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 24469 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51499	13041-10000-21489	5837-5841 W SUNSET BLVD UNITS 1-79	90028	13	147A191    55	5545011023	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			09/25/2013 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.09822	-118.3171	PLAN CHECK FOR POWER AND ENERGY. 79 UNIT APARTMENT COMMERCIAL. LOCATED IN CRA AREA. 3 LEVEL BELOW GRADE WITH 5 LEVEL TOTAL. 3 SERVICES. 75000 SQFT. VARIANCE TO SEPERATE FIRE ALARM SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51500	17041-20000-25099	10725 N SUTTER AVE	91331	7	207B157  1310	2535030001	M2-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.26491	-118.41977	new commercial single story building sub fed from an existing switchboard MSB. plan check for power and energy. no hazardous classification per applicant.BUILDING PERMIT # 17010-20000-02986	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51501	17041-10000-05156	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	Adding 60 new devices under Delta-4 only.  (Ref 16041-10000-36720)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51502	16041-10001-21086	7511 N PONCE AVE	91307	12	186B097   393	2022008018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.2069	-118.62227	EXPEDITE PER APPLICANT REQUEST.(((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.099KWdc / 11.0KWac.(37)MODULES-SUNPOWER SPR-327NE-WHJT-D(1)INVERTER-SMA 5000TL-US-22 & SMA 3800TL-US-22(1)INVERTER-SMA SB6000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51503	19041-10000-40295	6420 W WILSHIRE BLVD #220-LL	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	05/04/2023 12:00:00 AM	ADDRESS	34.06365	-118.36922	TI IN AN EXISTING COMMERCIAL SPACE. INSTALLING NEW LIGHT. AFFECTED AREA: 3000 SQR FT.Building Permit: 19016-10000-31815	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51504	19041-10000-14638	7633 N YARMOUTH AVE	91335	12	186B129   112	2120005001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Closed	08/01/2023 12:00:00 AM	ADDRESS	34.20957	-118.51995	PV1, system size is 7.6KWac/ 8.7KWdc. Scope of work includes 30 modules with optimizers (P370), a central inverter (SE7600H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51505	17041-10001-37032	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.05885	-118.44283	Change to approved set by modifying the lighting plan. all changes under delta-1 only.(((PC for T24 only for new lights in lobby, basement and outdoor in high rise building. Installed load under 400A. Total area indoor is 24607sqft and 24744sqft outdoor. Building# 17014-10000-04521.B# 17014-10000-04521)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51506	15041-20000-20261	11620 W WILSHIRE BLVD Suite 600	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	Plan check for Title 24 only. Project site is an existing commercial building (Suite 600). Project scope is a tenant improvement. Total lighting area = 9,100 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51507	15041-20000-22776	9201 N OAKDALE AVE Suite 100	91311	12	198B113   214	2761001084	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.2381	-118.56706	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,157 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51508	17041-20000-39575	11755 W WILSHIRE BLVD 23rd Floor	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for Title 24 only. Project site is the 23rd floor of an existing commercial building. Project scope is a tenant improvement, in Elevator lobby, restroom, and corridor. Total lighting area = 1,811 sq. ft.Note: Building application has been generated under 17016-10000-19962	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51509	11041-10000-19370	7857 W MANCHESTER AVE	90293	11	096B153  1188	4115024018	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Public Safety Only			09/13/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	33.95994	-118.43455	new fire warning system with central station monitoring for 3-stories condo building; note that there are 2 ea power expanders on level P1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51510	15041-10000-11997	8271 W BEVERLY BLVD	90048	5	138B173   393	5514009052	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.07623	-118.36975	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2270.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51511	16041-10000-42329	4755 S ALLA ROAD	90292	11	105B157   549	4212007006	P-1, [Q]MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	33.9835	-118.43032	PC FOR ENERGY. REPLACE OUTDOOR   FIXTURES WITH NEW LED FIXTURES  TOTAL AREA 85825 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51512	19041-10000-16893	21029 W OSBORNE ST	91304	3	195B105    42	2779048008	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	06/11/2019 12:00:00 AM	ADDRESS	34.23316	-118.59177	"PC FOR ""FIT"" Plan check for a 166kw AC / KW DC PV2 roofmounted system with (2) inverter, (432) modules, (216) optimizer interconnecting through the main service panel.SERVICE EQUIPMENT AND DISTRIBUITION UNDER EXPRESS PERMIT."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51513	14041-10000-24757	5518 N VENTURA CANYON AVE	91401	4	174B157   777	2344005007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.17078	-118.42893	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.9 KW AC. (24) ENPHASE M215 MICROINVERTER(24) LG 275 SLC MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51514	17041-10000-03074	20977 W KNAPP ST	91311	12	198B109   208	2746009012	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.23872	-118.59108	PC for Indoor/outdoor title 24 only. Removing HID fixtures and replacing with new LED ones. Area: 6,000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51515	16041-20000-20447	326-338 S RENO ST	90057	1	136-5A201 249	5155009013	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Apartment			06/10/2016 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	01/19/2021 12:00:00 AM	ADDRESS	34.06744	-118.28363	New 5-story, 65-unit apartment building.  1600A 208Y/120V service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51516	19041-20000-06986	13250 W MERCER ST	91331	7	210B157   832	2535016005	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	34.26913	-118.42142	pv1install roof mounted pv system sized 4.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51517	12041-10000-23476	14919 S FIGUEROA ST	90248	15	072B201    37	6120029002	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30, 2912.10	Electrical	Electrical	Commercial			10/02/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Issued	10/30/2012 12:00:00 AM	ADDRESS	33.89655	-118.28338	upgrade service to existing building to accomodate for future loads using old swbd as a distributing board	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51518	17041-30000-38671	9200 N OAKDALE AVE 7th Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is an existing commercial tenant space in a high-rise building. Project scope is a tenant improvement. Total lighting area = 9,635 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51519	16041-20000-24931	5077 N LANKERSHIM BLVD STE E	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.1626	-118.37361	TI TO AN EXISTING COMMERCIAL BUILDING TENANT E.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  ALL BRANCH CIRCUITS ARE NEW.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 2775.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51520	13041-10000-27110	5519 N VOLETTA PL	91607	2	174B161   561	2346001006	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.17083	-118.41123	PV1. ROOF MOUNTED 9KW  PHOTOVOLTAIC SYSTEM. CENTRAL INVERTER STANDARD PLAN.(36) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51521	19041-20000-28099	23551 W CALIFA ST	91367	3	177B093   849	2041002010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.17747	-118.64019	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 13.52KW DC/11.97KW AC. SCOPE OF WORK INCLUDES (22) SUNPOWER SPR-X22-360-E-AC PV MODULES, (16) SUNPOWER SPR-X21-BLK-350-E-AC PV MODULES, BOTH WITH INTEGRATED MICROINVERTERS, AND A 100A SOLAR SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51522	19041-20000-29671	8360 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM				Sales office first time tenant in model home.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51523	16041-20000-02863	19116 W LOS ALIMOS ST	91326	12	207B121   268	2718018004	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.26572	-118.54962	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (25) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51524	10041-10000-08432	1850 W MANCHESTER AVE	90047	8	097-5A193 346	6036011031	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00, 2384.00	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	11/02/2012 12:00:00 AM	ADDRESS	33.95979	-118.31086	INSTALL A NEW FIRE LIFE SAFETY SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51525	12041-10000-04380	931 E PICO BLVD	90021	14	123A211   217	5132013026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Closed	02/03/2015 12:00:00 AM	ADDRESS	34.03089	-118.24937	TITLE 24 ENERGY ONLY. LIGHTING AND RECEPTICLES. 4 STORY COMMERCIAL BUILDING. WORK DONE ON 2ND FLOOR ONLY. APPROX 9500SQ FT (2ND FLOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51526	13041-10000-19485	7130 N POMELO DR	91307	12	183B089   156	2028042023	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.19999	-118.64874	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE FAMILY DWELLING. SYSTEM SIZE IS 7.84 KW. 21 MODULES, 2 INVERTERS. [INVERTER: SOLAREDGE# SE3800A-US |||| MODULES: TRINA SOLAR # TSM-245PC05/PA05.18]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51527	14041-10000-09465	7160 W SUNSET BLVD	90046	4	147B181   677	5548018027	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.09778	-118.34615	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. 1 PANEL AND 3 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51528	18041-30002-12899	8620 S AIRPORT BLVD	90045	11	096B169   631	4125009020	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	33.95899	-118.38536	CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA 3 CHANGES. NEW RESCESSED LIGHTS ADDED. <<<Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the ground floor. Total lighting area = 6,000 sq. ft.Note: Building application has been generated under 17016-30001-05804>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51529	17041-10000-22371	3467 E WHITTIER BLVD	90023	14	121-5A227 147	5188004037	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.027	-118.19883	PC for power and energy for new youth center building.  New service 600A 120/208 VScope includes new panels, circuits and equipment. Total affected area 4935 sq.ft Building 17010-10000-02580.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51530	17041-20000-04635	14216 W GILMORE ST unit 1	91401	6	180B153   960	2237020009	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.18753	-118.4429	pv2install roof mounted pv system sized 3kw interconnected with msp.  This is system 1 of 5.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51531	12041-20000-25640	3415 S SEPULVEDA BLVD 12th floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.02055	-118.42347	Install new lighting in the restrooms, corridor, and elevator looby of the 12th floor.  Plan check for T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51532	15041-10000-12374	140 E HURRICANE ST	90292	11	103-5A147 272	4225010900	RW1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	33.97589	-118.46122	REPLACEMENT/UPGRADE OF EXISTING ELECTRICAL EQUIPMENT AT THE VENICE PUMPING PLANT AS PART OF THE EMERGENCY GENERATOR REPLACEMENT PROJECT. PC FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51533	15041-10000-13179	921 S CROCKER ST C-10	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	pc for energy only. TI for retail building. total area 1760 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51534	13041-10001-28202	4559 N MATILIJA AVE	91423	4	168B153   604	2271005001	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.15463	-118.43417	Layout of the modules on the roof changed.PV1. ROOFMOUNTED SOLAR ARRAY. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 6.5 kW DC. 1 STORY HOUSE. (26) SPARP ND-Q250F7 MODULES(26) ENPHASE M215-60-2LL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51535	19041-20000-20486	950 E 3RD ST Bldg 2-Suite 4	90013	14	127-5A217 112	5163016017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	12/03/2021 12:00:00 AM	ADDRESS	34.04578	-118.23334	PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES T24, (77) BRANCH CIRCUITS, (5) PANELS, AND (8) EQUIPMENT LOADS. TOTAL SQUARE FOOTAGE = 3031 SF.Building #2, Suite #4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51536	15041-20001-37144	12330 N EL ORO WAY	91344	12	219B133   553	2608022019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.41	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM			Reviewed by Supervisor	11/17/2015 12:00:00 AM	ADDRESS	34.29483	-118.50466	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8 KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51537	19041-10000-16132	1256 W 7TH ST 3RD FL	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.05216	-118.26774	NEW LUMINAIRES AND BRANCH CIRCUITS IN THE 3RD FL KITCHENpLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51538	19041-10000-04425	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.12626	-118.21412	THE PROPOSED PROJECT CONSISTS OF non-sales 347 SF OUTDOOR, LATTICE-ROOF LOUNGE AREAPlan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51539	14041-20001-02598	7466 N LOUISE AVE	91406	6	186B133  1166		R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.20652	-118.50969	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51540	12041-10000-01453	7366 N HAYVENHURST AVE	91406	6	186B137   238	2226001907	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Expired	10/09/2018 12:00:00 AM	ADDRESS	34.20377	-118.49397	"INSTALL A NEW SPRINKLER MONITORING SYSTEM IN AN EXISTING ""CASTLE & COOK AVIATION"" HANGER IN THE VAN NUYS AIRPORT.  1 @ FACP & 5 @ DEVICES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51541	19041-10000-42188	300 S MISSION ROAD	90033	14	127-5A219 153	5172015001	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.04423	-118.22747	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51542	11041-10000-21004	6081 W CENTER DR STE #201	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	33.97811	-118.39245	T.I. TO AN EXISTING MOVIE THEATRE CONCESSION STAND.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51543	14041-10000-00922	702 E GAGE AVE	90001	9	105B205  1041	6007017004	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	33.98174	-118.26272	Ti in a storage. EPC is for T24. Existing emergency and ckt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51544	13041-20001-29804	1500 W PACIFIC COAST HWY A-L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	[[[[[ 2/5/15  CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA 3 CHANGES. CHANGES TO THE LOCATION OF MSB DBL, DBK , DBJ AND DBI. FEEDERS FOR DBX AND DBE REROUTED AWAY FROM UNDERNEATH THE BUILDING( SAME DISTANCE). NEW ENGINEER DUE TO THE PASSING OF THE PREVIOUS STAMPING ENGINEER]]]]]BUILDING A:   NEW APARTMENT COMPLEX CONTAINING 12 SEPERATE BUILDINGS UNDER THE SAME ADDRESS. (2) 4000A SERVICES. PER APPLICANT REQUEST SUBMITTED AS ONE LUMP SUM. METHANE ZONE, HAS METHANE REPORT.Note: Variance to separate Methane Detection System has been filed.Permit Bld. B is under 14041-20000-06842Bld. C is under 14041-20000-06845Bld. D is under 14041-20000-06846Bld. E is under 14041-20000-06848Bld. F1 is under 14041-20000-06850Bld. F2 is under 14041-20000-06875Bld. G is under 14041-20000-06852Bld. H is under 14041-20000-06853Bld. I is under 14041-20000-06854Bld. J is under 14041-20000-06856Bld. K is under 14041-20000-06858Bld. L is under 14041-20000-06859Bld. Recreation is under 14041-20000-06860	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51545	18041-10000-10626	2727 S KRIM DR	90064	5	126B165   597	4308015016	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.04119	-118.40004	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND TWO ENERGY STORAGE SYSTEMS (TESLA POWERWALL TOTAL 27 KWH ) IN A SINGLE FAMILY DWELLING. SYSTEM CONSIST OF 30 MODULES AND TWO CENTRAL INVERTERS (DELTA SOLIVIA 5.2 AND 3.8) CONNECTED TO A PV ONLY PANEL. SYSTEM SIZE IS 9 KWac AND 9.75KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51546	13041-10000-26151	8600 W 3RD ST # 2	90048	5	138B169   567	4334009018	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.07344	-118.37992	Convert existing retail space to medical office (792 sqft). Title 24 plan check for lighting.  Permit obtained by applicant under 13041-10000-21710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51547	10041-10000-03034	17200 W VENTURA BLVD #225	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1VL, C2-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			02/22/2010 12:00:00 AM			Corrections Issued	02/22/2010 12:00:00 AM	ADDRESS	34.16035	-118.50769	T.I. for existing commercial space (Yogurtland).  Install emergency and general lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51548	16041-20000-08500	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	33.79072	-118.29449	Plancheck for addition of 11 RPS's and 199 devices to existing firealarm system. kaiser permanente medical center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51549	19041-20002-28670	2757 S MOTOR AVE	90064	5	126B165   543	4308010018	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2019 12:00:00 AM			PC Approved	09/20/2019 12:00:00 AM	ADDRESS	34.04162	-118.40352	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. CHANGE TO SINGLE LINE. CHANGE TO MAIN BREAKER SIZE AND RELOCATION OF MAIN PANEL LOADS TO A NEW SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51550	18041-10000-28977	401 E 7TH ST	90014	14	127-5A211 284	5148024026	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			08/23/2018 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.04196	-118.24829	PC FOR NEW 6-story, 99-unit, affordable housing apartment building.NEW 2500 120/208 3PH SERVICE.  TOTAL AFFECTED AREA 27319 SQ. FT  (INDOOR + OUTDOOR)ONE TYPICAL UNIT WITH  SINGLE MANAGER UNIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51551	15041-10000-43659	1200 W 7TH ST	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.05136	-118.26616	PC for energy only to a commercial building. Scope of work is being done in partial spaces at the 5th floor. Total SQft =  1784	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51552	18041-10000-27683	2131 W COLORADO BLVD	90041	14	162A223    98	5671010003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.13937	-118.21279	"Change of use from Retail to Restaurant. Existing 400 Amp service & panels. Install new circuits.Plan Check for T-24 Energy ONLY.  ""COMPLY WITH DEPARTMENT ORDER effective date11/27/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51553	15041-20000-23258	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	(T)(Q)M2-1, MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for the replacement of a 4160/480-277 1500 kVA substation transformer one for one.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51554	19041-10000-03131	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.14436	-118.27496	pc t-24 only for a lab in Kaiser. effected area 454 Sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51555	18041-20000-06694	1200 W MANCHESTER AVE	90044	8	097-5A197 346	6047002001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	33.95985	-118.2961	replace existing lighting fixtures with new led.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51556	17041-10000-46559	1125 W 190TH ST	90248	15	060B197   545	7351028021	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.85848	-118.29593	PC FOR NEW FA SYSTEM IN A 2 STORY COMM. BUILDING. SCOPE INCLUDES 116 DEVICES WITH  A SINGLE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51557	19041-20000-33331	10910 W PEACH GROVE ST	91601	2	168B173   314	2421014031	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Apartment			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.15889	-118.36851	Plan check for Fire alarm system for Townhomes. Total fire alarm devices: 50 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51558	10041-10000-06360	2524 S VERMONT AVE	90007	1	123B197   883	5055004026	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.03314	-118.29134	"1st time tenant. Existing 1200Amp Service, New Panel & Circuits. Plan chek is for power & energy in ""PIZZA PATRON""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51559	18041-20003-17751	11805 W GWYNNE LANE	90077	5	153B141   103	4378037075	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.11583	-118.47417	1/17/2019changes to an approved set of plans.  changes to module rating, solar city standard SC330.this is plan check only.  ((((PV1.  Install 9.425 kW DC roof mounted grid tied PV system.  (29) modules with (2) 5.2 kW rated string inverters.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51560	10041-20000-18323	23305 W MULHOLLAND DR	91364	3	168B093   181	2074001042	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.15615	-118.63354	T.I. to existing building from office space to dental space.  Install some new branch circuits.  EPC for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51561	17041-10000-29459	12301 W SHERMAN WAY	91605	2	183B165    20	2307021005	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.20137	-118.40102	REMOVE EXISTING (10) HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 21300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51562	17041-10000-00305	400 W WORLD WAY	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM			PC Approved	01/06/2017 12:00:00 AM	PIN	33.94340087	-118.39046685	PC FOR ENERGY. TENANT  IMPROVEMENT IN EMPLOEES BREAKROOM (LAX). CONNECTED LOAD < 400A. TOTAL AREA 892 SQ FT. B# 16016-10000-14927.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51563	15041-10001-37316	616 S KENMORE AVE	90005	10	135B197  1102	5502028022	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.06289	-118.29646	03/08/2017 Changes to an approved set of plan. Changes include addtional fire alarm devices 8 devices and relocate Fire alarm dvice. Changes apply to delta 1 only. {{{{{{INSTALL NEW FA SYSTEM FOR A 6-STORY APARTMENT BUILDING. 117 FA DEVICES, 1 FA PANEL, 1 FA COMMUNICATION APNEL, AND 4 CONTROL PANEL.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51564	16041-10000-12363	1175 E 21ST ST	90011	9	120A211   109	5131009036	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2016 12:00:00 AM			Corrections Issued	04/08/2016 12:00:00 AM	ADDRESS	34.02369	-118.25356	Installation of new roof mounted solar PV array on existing duplex.  Total system size = 2.5 kWac.  Central inverter system.7/11/16: Permit is pulled and PC under 16041-10000-12506	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51565	10041-10000-20662	10700 W SANTA MONICA BLVD	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	08/29/2011 12:00:00 AM		Permit Finaled	11/03/2011 12:00:00 AM	ADDRESS	34.05167	-118.432	New CHASE Bank. Plan Check is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51566	15041-10000-25082	143 W FLORENCE AVE	90003	9	102B201   807	6012013026	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	33.97488	-118.27557	PC FOR ENERGY ONLY, T-24 TO A (N) BUILDING. BUILDING CONTAINS A DUPLEX AND A COMMERCIAL TENANT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES, 200AMP SERVICE. TOTAL SQ. FT. 266	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51567	15041-10000-27494	8436 W 3RD ST 8&9 FL.	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.07301	-118.37448	Medical office TI (13,697 sq. ft.) for 8th and 9th floors of (E) commercial highrise building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51568	12041-10000-28750	"3740 W EVANS ST BLDG ""A"""	90027	4	150B201   845	5433023040	R2-1XL	Central	Hollywood	Greater Griffith Park	YES	1952.01	Electrical	Electrical	Apartment			12/11/2012 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.10626	-118.27387	"ALTERATION OF FOUR BUILDINGS ""A"", ""B"", ""C"" & ""D"". SERVICE UPGRADE,  ADDITION OF NEW METERS AND DISTRIBUTION PANELS, ADDITIONAL CIRCUITS TO UNITS, NEW AC UNITS,  NEW UTILITY TRANSFORMER ON SITE. THIS PERMIT IS FOR BUILDING ""A"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51569	12041-20000-03104	6201 W HOLLYWOOD BLVD	90028	13	148-5A189  54	5546031001	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Closed	10/02/2014 12:00:00 AM	ADDRESS	34.1018	-118.32461	Temporary 1600A service power for construction site of a new mixed-use building.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51570	11041-20000-26547	8444 N CANOGA AVE	91304	12	192B105   315	2779014028	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	ADDRESS	34.22348	-118.59686	New 3.68 KW roof mounted PV system for a single family residence.  Appicant is using the M215.  A variance has been filed to use the microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51571	19041-10000-25187	955 N OXFORD AVE 1-9	90029	13	144B193  1193	5535021005	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Apartment			07/01/2019 12:00:00 AM			Reviewed by Supervisor	08/01/2019 12:00:00 AM	ADDRESS	34.08783	-118.30791	PC FOR  REMODEL TO (E) APARTMENT BUILDING AND (E) DETACHED GARAGE . NEW WASHER AND DRYERS AT EACH UNIT. 9 UNITS , SERVICE SIZE 600A, 1PH, 3W. AREA OF SCOPE 3290.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51572	17041-10000-01571	10925 W KINROSS AVE	90024	5	132B149    92	4363024017	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.06062	-118.44628	Full plan check.  Change of use from retail to salon.  New service rated at 800 amps. 120/240V.   All new equipment, new lighting and power.  Total area: 2335.Fire alarm variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51573	18041-20001-19646	2919 N NORTH BROADWAY	90031	1	138A223    38	5204023003	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			12/14/2018 12:00:00 AM			PC Approved	12/14/2018 12:00:00 AM	ADDRESS	34.07387	-118.21084	122/14/2018changes to an approved set of plans. changes to aluminum service entrance conductor and main service fuse 500 amp.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51574	19041-20000-05375	4947 W LOS FELIZ BLVD	90027	4	150B197   119	5588009004	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.11031	-118.29732	Plan check for PV roof mounted and Battery system, PV system size: 10.7KW DC, 10.6KW AC with 37 PV Modules and 2 inverters(7.6KW and 3.0KW) and 1 LG Battery RESU 9.8KWh	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51575	18041-10000-28638	11336 W GOSS ST	91352	6	192B173   446	2632005010	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.22	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.22237	-118.37795	PLAN CHECK FOR FOR TITLE 24 FOR REMOVAL OF HID FIXTURE TO NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51576	17041-20000-22359	116-120 N ROBERTSON BLVD	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.0758	-118.38356	PLANCHECK FOR T24 ENERGY ONLY. T.I. FOR BIKE STORAGE AND ELECTRICAL ROOM ON THE PARKING LEVEL. HIGH RISE. NO EMERGENCY LIGHTING. 2116 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51577	19041-20000-03805	15846 W NAPA ST	91343	12	192B141   100	2673009035	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.22642	-118.47802	Plan check for PV roof mounted system, system size: 9.1KW, 10.4KW AC with 28 PV Modules and 2 inverter(5.2KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51578	19041-20000-35360	5919 N RESEDA BLVD	91356	3	177B125   808	2156025022	R3-1	South Valley	Encino - Tarzana	Tarzana		1393.02	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			Reviewed by Supervisor	09/19/2019 12:00:00 AM	ADDRESS	34.17806	-118.53633	Plan check for PV roof mounted system, PV system size: 12.96KW with 32 PV Modules and 1 inverter(10.0KW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51579	14041-10000-27242	11630 W TUXFORD ST	91352	6	192B169   355	2632023049	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.22408	-118.38532	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 16574 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51580	17041-20000-03768	7500 N LANKERSHIM BLVD	91605	2	186B169   461	2316013003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.20684	-118.38758	Plan check for a fire alarm system for a gym. System consists of (1) FACP, (1) annunciator, and (27) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51581	19041-10000-26367	9027 N CANOGA AVE STE J	91304	3	195B105    39	2779018039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.23429	-118.59779	T-24, PC for energy only. Remove HID fixtures and replace with new LED fixtures (Indoor Only). Total affected area is 750 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51582	19041-20000-36171	6701 S CENTER DR WEST Ste 770	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	TI to commercial office tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51583	17041-10001-10899	8620 S AIRPORT BLVD	90045	11	096B169   631	4125009020	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	33.95899	-118.38536	Changes to approved set.  Scope of work increased to > 400 amps connected load.  Power plan check for complete system and permit for added equipment included on 17041-10001-10899.   Title 24 plan check and permit for original equipment under master application 17041-30000-10899.   Scope includes new lights in corridors and remodel guest rooms and storage rooms on floors 2-6 of existing 6 story hotel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51584	15041-20000-16517	16515 W BALLINGER ST	91343	12	201B137   947	2677005004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.24394	-118.49185	pv1 sfd. total system size 3.2kw ac using microinverter system. using enphase m215. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51585	19041-10000-43413	1940 W 25TH ST	90018	8	123B193   487	5058019016	RD1.5-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.03368	-118.30698	REMOVE HID FIXTURES AND REAPLCE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51586	19041-10000-20062	1820 S GRAND AVE	90015	14	124-5A205  58	5126026005	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.03356	-118.26756	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51587	13041-20000-32818	5900 W WILSHIRE BLVD SUITE 1550	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. NEW LIGHTING. work done in suite 1550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51588	18041-10000-15153	7443 N LAUREL CANYON BLVD	91605	2	186B165   413	2307020031	C2-1VL, M1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Issued	04/25/2018 12:00:00 AM	ADDRESS	34.20578	-118.39677	REMOVE EXISTING HID FIXTURES AND REPLACE THEM WITH NEW LED FIXTURES. TITLE 24-ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51589	17041-10000-22794	11601 W WILSHIRE BLVD FLR 21ST	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR RESTROOMS CORRIDOR AND LOBBY  TI IN A HIGH RISE (21th FLOOR) FOR TITLE 24  ENERGY ONLY. TOTAL AFFECTED AREA  1600 SQ.FTINSTALLING NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51590	15041-10002-22296	15915 W INDEX ST	91344	12	210B141    80	2666013013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM			PC Approved	08/05/2015 12:00:00 AM	ADDRESS	34.27564	-118.47863	EXPRESS RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 8.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON ONE SINGLE FAMILY HOUSE.(29) MODULES: LG280S1C-B3(1) INVERTER: SMA AMERICA-SB7000TL-US-22>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51591	18041-10001-15216	811 E TRACTION AVE #3A	90013	14	127-5A215  36	5163015008	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.0452	-118.23546	TI  IN AN EXISTING OFFICE BUILDING ON THE 3RD FLOOR. PLAN CHECK FOR TITLE 24 ENERGY ONLY.BUILDING PERMIT NUMBER: 18016-10000-11108	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51592	16041-20000-32514	6400 1/2 W HOLLYWOOD BLVD	90028	13	148-5A187 174	5546007010	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	PIN	34.10137526	-118.32983045	Plan check for energy only. New lighting for dining area and restrooms in commercial space. 980sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51593	11041-10000-10207	9601 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Issued	05/31/2011 12:00:00 AM	ADDRESS	34.24501	-118.59876	NEW FIRE ALARM FOR A SINGLE STORY MANUFACTURING BUILDING.  REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51594	13041-20001-21838	9727 W OAK PASS ROAD PV-1	90210	5	153B157    99	4384007035	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	ADDRESS	34.11784	-118.42776	((Expedite fees))PV-1. Plan check for PV. 8kW with combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51595	13041-10000-22100	300 S GRAND AVE STE LP0700	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			Corrections Issued	08/16/2013 12:00:00 AM	PIN	34.05243427	-118.25124731	TI for existing fast food restaurant space in high rise building food court.  Title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51596	19041-20000-18313	4517 N FIRMAMENT AVE	91436	5	168B141   863	2283002009	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.15298	-118.47228	PLAN CHECK FOR NEW PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE 17.49KW DC/16.3KW AC CEC/11.4 KW AC. SCOPE OF WORK INCLUDES (53) PANASONIC PV MODULES WITH P400 OPTIMIZERS AND A SE11400 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51597	12041-10000-17705	12016 N EDDLESTON DR	91326	12	216B125    49	2870005031	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.29101	-118.53753	New 6.24kw rooftop mounted PV system for an existing single family residence.  System uses Enphase M215 Micro-Inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51598	19041-10000-39014	927 S GENESEE AVE	90036	4	132B177   539	5086019006	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.05869	-118.36049	[Eplan] Plan check  for 2 New Energy Storgae Systems(Tesla Power wall) @27KWH connected to existing pv system and 225a service	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51599	17041-10000-07271	310 N HAWAIIAN AVE LOT7, B 7	90744	15	027B201   392	7417010908	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM				INSTALLATION OF A NEW FA SYSTEM FOR A 3-FLOOR APARTMENT BUILDING. 2 FA PANELS AND 42 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51600	18041-20001-05807	17641 W RAYEN ST	91325	12	195B129   188	2768027008	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.23234	-118.51936	4/26/18changes to an approved set of plans.  changes noted delta 1.  changes to reflect field conditions.  (((Plan check for power only. Project site is a single family dwelling. Project scope is the addition of a Tesla PowerWall to an existing roof-mounted PV system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51601	11041-10001-12723	6310 W SAN VICENTE BLVD # 220	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			PC Approved	06/27/2011 12:00:00 AM	ADDRESS	34.06084	-118.36757	Per inspector, Title-24 plan check only.  Remodel of Dr.  Boodaghian's ofice.  Suite #220.  <<<<<T.I. RECEPTACLES & LIGHT FIXTURES.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51602	10041-20000-15412	2009 N MOUNT OLYMPUS DR	90046	4	151-5A175 200	5569035010	RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.10825	-118.36603	solar system over 10 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51603	14041-20001-01340	11119 N CABRIOLE AVE	91326	12	210B121   312	2717006004	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.27207	-118.54107	((EXPEDITE FEES))PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 7.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51604	14041-10000-28946	10979 W BLUFFSIDE DR BLDG 4	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	Note to plan check engineer, applicant returns and swaps in a new plan with additional circuits added on after original fee was paid. Plan check engineer needs to verify fee with all new changes. Per F.Y.(((Installing new washer/dryers and booster fans in apartment units.  Bldg 4 of 6.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51605	18041-20000-31209	16743 W SCHOENBORN ST C	91343	12	192B137   231	2689012013	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	05/24/2019 12:00:00 AM		Issued	05/24/2019 12:00:00 AM	ADDRESS	34.22285	-118.49793	Tenant improvement to (E) 2-story commercial building tenant space.  Plan check for power and energy.  Generator supplying additional loads not connected to service.Building permit issued under 18016-10000-13623.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51606	17041-10000-03130	2029 S CENTURY PARK EAST 11TH FLR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24, PC for energy only. Interior T.I. to 11th floor men's and women's restrooms within the common area to (e) Office Building. Total affected area is 380 Sq. Ft.  B#16016-10000-29589	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51607	11041-10000-18237	8500 W OLYMPIC BLVD	90035	5	132B173   353	4332030028	C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	34.05926	-118.37666	TI TO AN EXISTING 7-ELEVEN.  REPLACEMENT OF EXISTING LIGHT FIXTURES WITH LED FIXTURES.  PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51608	15041-10000-05773	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008023	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Expired	05/05/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	Temporary generator for fire pump operation during construction before release of power to site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51609	14041-10000-04859	11210 W PEACH GROVE ST	91601	2	168B173   285	2353022027	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			02/21/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	PIN	34.15890532	-118.3748892	PLANCHECK FOR POWER AND ENERGY FOR A NEW 15 UNIT APARTMENT. 3 STORIES.  FIRE ALARM PLANS SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51610	12041-10001-27734	2500 S NAVY WAY Maintenan-BLDG	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			11/16/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	33.73363	-118.2408	Modify existing fire alarm system for Pola Maersk (port of LA) 2of 6 Maintenance. Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51611	14041-10000-09899	10231 W VENICE BLVD	90034	5	120B165  1343	4314005005	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.02144	-118.40278	Title 24.  Remove HID light fixtures and replace with new fluorescent fixtures.Total area = 3486 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51612	17041-10000-34112	691 S MILL ST	90021	14	124-5A215  58	5164022012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.03499	-118.23474	Plan check for new fire alarm system for mixed use building. Total fire alarm devices: 209 and 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51613	17041-20000-34818	9410 N DE SOTO AVE	91311	12	198B109    75	2748002068	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM			PC Info Complete	07/19/2018 12:00:00 AM	ADDRESS	34.24147	-118.58834	Plan check for power and energy. Project site is an existing commercial building. Project scope is a fire damage repair. Work includes a new 4000 amp service and a total lighting area of 8,697 sq. ft.Note: Building permit has been  issued under 17016-20000-04534	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51614	18041-10000-07485	5600 W WILSHIRE BLVD	90036	4	132B181  1296	5089006***	(Q)C2-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.06214	-118.35085	PC for T24 only for replacement of indoor lighting to LED fixtures with LED driver for Chase bank. Egress lighting is not part of the scope. Total area Indoor  is 4470sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51615	13041-20000-26551	5900 W WILSHIRE BLVD #1600	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	TI energy plan check # 1600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51616	15041-10000-24058	1500 W PACIFIC COAST HWY Bldg D	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 5 unit apartment with garage, Typev VA construction. 18 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51617	19041-70000-38838												Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM					N	N	Express Permit	06/10/2024 12:00:00 AM
51618	12041-10000-24201	4225 S CENTRAL AVE	90011	9	114A209   153	5115019033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Public Safety Only			10/10/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.00695	-118.25669	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING FOR A BUILDING CHANGED FROM A HOTEL TO  APARTMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51619	17041-10000-41342	10325 W TABOR ST 1-42	90034	5	120B161   651	4314014002	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/07/2022 12:00:00 AM	PIN	34.02519429	-118.40712707	PC for power and energy for new apartment building with 7 story building with one level of commercial, ground level basement and subtarrenean basement. Installing new 1600A 120/240V service with two main distribution boards, subpanels, 42 unit panels, 80kW generator, equipment and cictuits. Total area is 52032sqft. B# 16010-10000-06155. NOTE address to change to 10325 Tabor Ave.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51620	16041-30000-21705	601 S FIGUEROA ST Suite 2775	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 320 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51621	10041-10000-21392	1600 W 240TH ST	90710	15	042B193   767	7439014013	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01, 2933.02	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	33.80713	-118.3054	TI IN AN EXISTING WAREHOUSE/OFFICE AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51622	12041-10000-02778	7520 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.20692	-118.4942	Plan check power and energy for new 37,760 sq ft airplane hanger with an additional 11,247 sq ft for office space.  Located at the Van Nuys airport.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51623	14041-20000-09217	5091 N CALATRANA DR	91364	3	171B105  1176	2168014064	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.1612	-118.60255	PV1Install roof-mounted solar array on SFD, interconnect with main panel.(28) PV Modules - Canadian Solar #CS6P-250PX(1) Transformless inverter - SolarEdge #SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51624	19041-10000-21606	10875 W LA TUNA CANYON ROAD	91352	6	195B173    14	2408004024	QM1-1-CUGU, QP-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.23453	-118.36812	Remove HID fixtures and replace with new LED fixtures- T24 only and Replace fluorescent troffers with new LED retrofit kits (Indoor and Outdoor)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51625	16041-10000-39022	6556 W HOLLYWOOD BLVD	90028	13	148-5A187 189	5547015017	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.10141	-118.33294	PC FOR TITLE 24 ENERGY ONLY IN A COMMERCIAL BLDG.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA  2136 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51626	12041-20000-08620	11425 N ALBERNI AVE	91342	2	213B177   203	2529007029	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	34.27697	-118.35572	New roof mounted P.V system with microinverter.  Replace main panel and install new subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51627	15041-10000-14598	340 S MAIN ST BLDG  B-LOBBY	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM			PC Approved	05/13/2015 12:00:00 AM	ADDRESS	33.99519	-118.47673	ALTERATIONS IN THE LOBBY OF AN OFFICE BLDGINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51628	16041-10000-17604	505 W 62ND ST	90044	9	105B201   859	6004025031	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	33.98338	-118.2831	PC for Power only. Service upgrade to 800A for a mix used 2 story (14 units) bldg. All other equipments are existing per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51629	19041-10000-02104	1011 S OCEAN FRONT WALK 1-2	90291	11	108A143   271	4226003004	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	33.98976	-118.47604	"PLAN CHECK FOR T24 ONLY, T.I. TO AN (E) RETAIL SPACE ""SNEAKERNSTUFF"" OF MIXED USE BUILDING.SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL AREA UNDER THE SOW: 6,433 SQ.FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51630	14041-20000-21931	11601 W WILSHIRE BLVD Ste 2040	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	Title 24 plan check only on a comereical building Suite 2040. Total working area is 6000 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51631	17041-10000-39114	5609 W SMILEY DR	90016	10	123B177  1486	5048025028	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM			Re-Activate Permit	01/30/2018 12:00:00 AM	ADDRESS	34.03011	-118.366	APPLICATION WITHDRAWN PER APPLICANT REQUEST. CHANGED TO PLAN CHECK ONLY!!PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 3.975KWDC/4.0 KWACSCOPE INCLUDES 15 MODULES AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51632	17041-20000-40038	5901 W OLYMPIC BLVD #109	90036	4	132B177   666	5086024025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.05771	-118.35996	PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT FOR MEDICAL OFFICE.BUILDING P# 17016-10000-28145	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51633	19041-20000-32288	8406 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51634	16041-10000-45589	12171 N CANYON HILL AVE	91342	7	216B145   233	2611043004	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.29165	-118.46628	PV , INSTALL NEW 5.79 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(23) MODULES: HANWA Q-CEL, Q-PLUS-G4 280W(1) INVERTER: SOLAR EDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51635	17041-10001-14659	3096 S MCCLINTOCK AVE SUITE 1415	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.02647	-118.28575	Supplemental for power only for new first time retail tenant. Original PC for T24 only. PC for two new panels and new cricuits. power equipment has been paid under master permit. this permit will cover plan check for power system and permit for change of address to add suite number 1415	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51636	16041-10000-17981	4402 S METTLER ST	90011	9	112-5A207  74	5109015013	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	07/16/2016 12:00:00 AM	ADDRESS	34.0037	-118.26636	PV1 INSTALL NEW 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51637	10041-10001-25423	8370 W 3RD ST	90048	5	138B173   843	5511031022	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM			PC Approved	01/18/2011 12:00:00 AM	ADDRESS	34.07279	-118.3724	Change the approved plan. Change the lighting & T24 calc. EPC is for the change.REMODEL EXISTING RESTAURANT. PLAN CHK IS FOR TITLE 24. PERMIT FOR NEW CKTS AND MISC. WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51638	11041-10007-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	33.94386	-118.4047	REVISION MADE TO PREVIOUSLY APPROVED SETS OF PLANS. ADDED TWO PANEL BOARD , RVISED ELEVATOR FEEDERS, REVISED MOTOR H.P. AND ADDED 15 NEW BRACH CKTS. FOR CENTRAL PLANT LAX. (((((((((((((((  tHE CLOUDED FEEDERS CHANGE FROM 200% NEUTRAL TO 100%. BECAUSE THE TRANSFER SWITCHES COULD NOT ACCEPT 200% NEUTRAL.))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51639	14041-10000-26437	6657 W SUNSET BLVD	90028	13	147A185    14	5547019031	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.09814	-118.33519	Title 24 plan check only.  Total area = 4592 sq. ft.  Remove HID light fixtures and replace with new fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51640	19041-10000-46672	2410 N LILLYVALE AVE	90032	14	139-5A237 104	5220034025	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM	03/09/2020 12:00:00 AM		Issued	03/09/2020 12:00:00 AM	ADDRESS	34.07504	-118.16432	Full plan check for power and energy. Scope includes adding new panels and transformers to an existing service. Total affected area is 8543 Sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51641	19041-10000-37402	7110 S MCKINLEY AVE	90001	9	102B205  1591	6007015022	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.97535	-118.26125	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51642	15041-10000-31407	12861 W RUNWAY ROAD lot 3	90094	11	102B157   394	4211033035	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	33.97535	-118.41996	PC for T-24 only per 2008 energy code, hardscape lighting. Total area 4323 sq. ft***scope located at: Lot 3 Tract 60110-01****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51643	17041-20000-05100	22153 W VALERIO ST	91303	3	186B101   589	2023013023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.20478	-118.60996	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.4KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51644	19041-20000-25321	1801 W OLYMPIC BLVD 3rd Floor	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.05046	-118.27663	Plan check for Title 24 only. Project site is the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,395 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51645	13041-10000-08104	10339 N MELVIN AVE	91326	12	204B117   107	2708024005	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	34.25837	-118.56022	photovoltaic system for single family dwelling. total suystem size 6 kw. using 30 modules. central inverter standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51646	18041-10001-03783	22846 W VENTURA BLVD	91364	3	171B097   554	2042005062	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Approved	04/12/2018 12:00:00 AM	ADDRESS	34.16531	-118.62473	CHANGES TO AN APPROVED SET OF PLANS. PC FOR TITLE 24 ENERGY ONLY FOR A NEW AUTOMOBILE RENTAL AND SALES. ALL CHANGES ARE CLOUDED UNDER DELTA 6. CHANGES INCLUDE ADDING J-BOXES FOR SIGN LIGHTING, AND REVISING PANEL SCHEDULES. NOTE: PERMIT IS PAID UNDER PCIS#18041-10000-03783	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51647	15041-20000-00821	17200 W OAK VIEW DR	91316	5	168B133   392	2289015001	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.15531	-118.50619	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 7.525kW. Ungrounded system.35 EnPhase M215 microinverters with 35  270W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51648	15041-10000-35189	2145 N MAYVIEW DR	90027	4	148-5A203 251	5430007013	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.10098	-118.27619	PV1 INSTALL 5.67 KWDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(18 MODULES: LG315N1C-G4(1) INVERETR: SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51649	14041-20000-08100	10221 N VALJEAN AVE	91343	12	204B137   454	2678004029	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.25621	-118.48725	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51650	17041-20001-33209	1210 W VENICE BLVD	90291	11	108B149   298	4236003019	[Q]R4-1XL	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Apartment			11/09/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	PIN	33.99476794	-118.45045604	[[11/9/17 PLANCHECK ONLY. TO UPDATE PLANS TO INCLUDE THE 5TH FLOOR ON THE RISER DIAGRAM.]]Replacement of defective fire alarm control panel and (1) new smoke detector.  Tie-in of existing devices to new FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51651	18041-20000-41708	19901 W NORDHOFF ST	91324	12	195B113    15	2782037034	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.23201	-118.56708	Plan check for Title 24 only in existing space replace new lighting only in clouded area only, all other lights are existing to remain.  Total area: 395 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51652	15041-10000-07468	759 N SPRING ST	90012	1	133-5A215  38	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	PIN	34.06161992	-118.23745547	Plan check for power and energy , work is on second and third floor. Inspector to verify routing of SEC. Changes on plan include updates to T24, Emergency lighting added for 2nd floor and put on general circuit, and lockon where exception used for unit equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51653	12041-10000-29371	10046 N ETON AVE	91311	12	204B105   683	2747013039	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.25317	-118.59499	PV1 SINGLE STORY ROOF MOUNTED SOLAR INSTALLATION. INTERCONNECTED WITH MAIN SERVICE PANEL. SYSTEM SIZE IS 6.24 KW. THREE STRINGS WITH 26 MODULES AND USING TRANSFORMERLESS INVERTERS [INVERTER: POWER-ONE # AURORA PVI-6000-OUTD-US ||||| PV MODULES:TRINA SOLAR # TSM-240PA05]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51654	17041-20000-34674	16908 W KINZIE ST	91343	12	201B133   305	2686025014	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.24844	-118.50059	Plan check for the addition of a battery back-up system to an existing PV system for a single-family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51655	18041-10000-37003	13805 W SATICOY ST	91402	6	186B153    11	2214019029	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.21	-118.43365	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51656	14041-10000-17042	777 S ALAMEDA ST SUITE 170	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.03396	-118.24117	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 7FORALLMANKIND . NEWLYCONNECTED LOAD <400 AMPS. 2160 SQFT, EMERGENCY LIGHITNG.  COMPLY W/ DEPT ORDER DATED 12/22/10. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. **INVESTIGATION FEE PAID THROUGH #12016-10000-16091**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51657	17041-10000-14108	531 S PARK VIEW ST	90057	1	133-5A203  16	5154038901	R4-1	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.06194	-118.27745	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 6500 SQ. FT. TOTAL OF 17 FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51658	16041-10000-02320	12690 W SANDHILL LANE UNIT 2	90094	11	102B161  1247	4211034***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Closed	11/10/2016 12:00:00 AM	ADDRESS	33.97692	-118.41538	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) MODULES(1) 3000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51659	19041-20000-36501	25975 S NORMANDIE AVE 1st Floor	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	33.78721	-118.29774	Plan check for Title 24 only for remove and reinstall existing lighting in the same location in Office location. All existing control shall remain at the same locationTotal area: 4452 sq ft.  B#19016-10000-16650	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51660	11041-10000-17673	2500 S NAVY WAY	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM			Corrections Issued	10/03/2011 12:00:00 AM	ADDRESS	33.73363	-118.2408	"INSTALL ONE NEW CONTAINER CRANE (#17) AT BERTH 406 IN PIER 400 IN ""CALIFORNIA UNITED TERMINAL""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51661	17041-20000-46034	8351 N SAN FERNANDO ROAD	91352	6	192B173   498	2632002008	[Q]C2-1-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM	06/25/2021 12:00:00 AM		Permit Finaled	06/29/2023 12:00:00 AM	ADDRESS	34.22169	-118.37313	T.I to an existing commercial building ( Banquet Hall).  service upgrade is 600 amps.  plan check for power and energy with a total area of 5,363-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51662	13041-10000-16817	11715 W BELLAGIO ROAD 1-23	90049	5	141B145   477	4368014019	[Q]R3-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Apartment			06/25/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.07869	-118.46956	PLAN CHECK FOR POWER AND ENERGY FOR A NEW APARTMENT BUILDING WITH 23 UNITS. FIRE ALARM VARIANCE TO FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51663	17041-10000-42137	5453 W LEMON GROVE AVE	90038	13	144B193  1316	5535008027	R2-1XL	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.08679	-118.31325	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51664	17041-10000-40562	2914 E 4TH ST	90033	14	124-5A225  13	5185013016	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2043.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.03726	-118.20484	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51665	11041-10000-17584	2616 N GLENDOWER AVE	90027	4	153B197   169	5588023040	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.11578	-118.29248	This is 4.6 kw pv , multi arrays , 400 amps service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51666	12041-10000-11421	750 S ALAMEDA ST	90021	14	123A215     9	5166031009	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM			Verifications in Progress	07/12/2012 12:00:00 AM	ADDRESS	34.03162	-118.23863	TITLE 24 AND EMERGENCY LIGHTING, SINLE  STORY , OFFICE , PART OF A  WAREHOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51667	15041-10001-07192	10926 W OLINDA ST	91352	6	192B173   136	2408013019	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			Reviewed by Supervisor	03/24/2015 12:00:00 AM	ADDRESS	34.22565	-118.36887	Expedite per customer request(((PV1 11kw roof-mounted system including (50) Kyocera KU2556 modules  and (2) ABB PVI-6000-OUTD inverters,  and (1) load center interconnecting through the main service..)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51668	12041-20000-05683	21054 W CLARENDON ST	91367	3	171B105    46	2167001011	(T)(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.168	-118.59193	T.I. to existing building.  Install general/emergency lighting in Wine area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51669	16041-10000-22482	631 S OLIVE ST SUITE 302	90014	14	129A209   124	5144004032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.04749	-118.25498	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT ON THE 3RD FLOOR OFFICE SUITE 302 IN EXISTING STORY OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 2065 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51670	18041-10001-07081	418 N NORTON AVE	90004	4	141B189  1134	5522022023	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.07908	-118.3169	Change to an approved set by adding (1) power supply, (6) ckts and (35) fire alarm devices on the plan. All changes under delta-1 only.(((Plan check for new fire alarm system for 4 story 35 units. Total fire alarm devices 150 and 1 FACP)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51671	19041-20001-07686	8717 N WOODMAN AVE	91331	6	195B153  1033	2637004033	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	34.22825	-118.43505	Recheck of lost set of plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51672	14041-10001-15802	8111 N REDBUSH LANE	91402	6	192B153  1194	2213003036	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	34.21891	-118.43747	Expedited RSES plan check per applicant request.{{PV1, Install 6.63 KW DC roof-mounted solar array on a 0ne-story house, interconnect with main service panel. Transformerless inverter. With optimizer.(26) Modules: Trina Solar # TSM-255pa05.18(1) Inverter: SOLAREDGE #SE6000A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51673	19041-20000-01443	245 N TOYOPA DR	90272	11	123B129   686	4411024027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.03161	-118.52	Installation of (2) Tesla battery back up (ESS) 5 kWh each to an existing PV system.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51674	14041-10001-09428	3174 W LARGA AVE	90039	13	153B209  1216	5436029012	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.11181	-118.25338	(((EXPEDITE FEES)))P V1 ROOF MOUNTED TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51675	19041-20000-33153	1537 S WILTON PL	90019	10	126B189   190	5073003006	R3-1-O-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.04	Electrical	Electrical	Apartment			08/22/2019 12:00:00 AM	12/14/2022 12:00:00 AM		Issued	12/14/2022 12:00:00 AM	ADDRESS	34.0442	-118.31468	1200A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51676	08041-10004-13153	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	10/15/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	Revisions to approved set based on Delta 4.   Install a 30KVA 480:208 3P and one panel and 5 projectors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51677	13041-10000-09568	4614 N GLENALBYN DR	90065	1	148-5A225 200	5466022012	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM			PC Info Complete	05/10/2013 12:00:00 AM	ADDRESS	34.09929	-118.20704	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 7.6KW. USING 31 PANELS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. POWER OPTIMIZERS. 2 INVERTERS AND LOAD CENTER. DC/DC CONVERTERS ARE CHARGED AS TOTAL KW TRANSFORMED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51678	11041-10000-13730	525 S SPRING ST	90013	14	129A211   143	5149035012	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/01/2011 12:00:00 AM			Corrections Issued	08/19/2011 12:00:00 AM	ADDRESS	34.04687	-118.25034	NEW 7-STORY, PLUS BASEMENT, PARKING GARAGE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51679	16041-20000-02829	18527 W ELKWOOD ST	91335	3	189B125   581	2103022016	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.21315	-118.53706	Plan check for PV roof mounted system. System size: 3.8kW with 15 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51680	19041-10000-09973	5221 N EAGLE ROCK BLVD	90041	14	163-5A223 165	5671014004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2019 12:00:00 AM	03/20/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.14164	-118.21408	NEW ROOF MOUNTED 3.8 KW SOLAR SYSTEM WITH 11 PV PANELS ON A SINGLE FAMILY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51681	12041-10001-13120	11686 W TUXFORD ST	91352	6	192B169   433	2632023027	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.22279	-118.38707	Revision to approved plans. Changes to inverter voltage, add additional AC disconnects, add 75KVA transformer, and change point of interconnection to supply side tap. No change on DC side.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51682	15041-20000-02391	11100 N LOUISE AVE	91344	12	210B133   467	2697006017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.27229	-118.51074	Roof mounted PV system with total size 3.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51683	17041-20000-29701	1141 E 12TH ST	90021	14	123A213   184	5132015040	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.03074	-118.24629	Plan check for power only. New 1,000A 277/480V 3ph 4w service and distribution equipment for existing commercial building. Building to be restored to core and shell condition - all loads on plan are temporary.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51684	17041-20000-01689	6656 N LANGDON AVE	91406	6	180B145   192	2234018029	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.19188	-118.469	PV1.  Install 8.19 kW roof mounted grid tied PV system.  (26) modules with 7.6 kW rated central inverter with power optimizers.  (E) 7.6 kW rated system already installed on site.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51685	16041-10000-20671	2315 S CHARITON ST	90034	10	126B173   977	4301026041	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	34.03802	-118.37835	PV1 SFD TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER SYSTEM WITH ENPHASE M215. 16 TOTAL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51686	17041-10000-06498	10854 W STRATHERN ST	91352	2	189B173   251	2409006039	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.21555	-118.3679	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(18)MODULES-AXIPOWER AC-265P/156-60S(1)INVERTER-FRONIUS PRIMO 5.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51687	11041-10001-22857	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM			PC Approved	03/29/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	DELTA 1 REVISION. REDUCE SCOPE OF WORK FROM APPROVED PLANS. REMOVE 4 BRANCH CIRCUITS FROM PANEL,  FIXTURE A EXISTING TO REMAIN, AND REVISE T24 CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51688	19041-20000-46511	15110 W SUTTON ST	91403	4	166-5A147 211	2276023003	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.14919	-118.46304	Installation of 27 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51689	19041-20000-49664	21304 W VELICATA ST	91364	3	171B105  1174	2167008008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.1612	-118.595	PV1. INSTALL 11.34 KW DC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51690	10041-10000-05846	9261 N JORDAN AVE	91311	12	198B105   217	2746013035	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.23886	-118.60411	New fire alarm	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51691	19041-10000-37903	1818 W 71ST ST	90047	8	102B193  1202	6016036018	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Apartment			09/20/2019 12:00:00 AM	05/19/2020 12:00:00 AM		Issued	05/19/2020 12:00:00 AM	ADDRESS	33.97522	-118.30968	0$ FINAL FEES PER AB1414PC FOR PV2 SYSTEM, SYSTEM SIZE IS 35.52KW-DC, 25.2KW-AC. SYSTEM WILL BE MOUNTED ON THE ROOF OF A RESIDENTIAL APARTMENT UNITS. SYSTEM CONSISTS OF (96) HYNDAI MODULES WITH OPTIMIZERS, (2) SOLAREDGE SE7600H INVERTER AND (1) SOLAREDGE SE10000 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51692	13041-20003-32067	1011 S GRETNA GREEN WAY	90049	11	129B145  1020	4264023010	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.04606	-118.46981	(((changes to approved set of plans. changes clouded delta 1))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING 33 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 4 STRINGS. 2 INVERTERS.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51693	08041-10005-05533	600 S SPRING ST	90014	14	129A211   252	5144001020	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM			PC Approved	02/17/2010 12:00:00 AM	ADDRESS	34.04568	-118.25098	REVISIONS TO APPROVED SET OF PLANS WITH CONNECTED LOAD REMAINING THE SAME- REMOVED SUMP PUMPS FROM HDB-1BE AND CONNECTED THEM TO DB-A; CHANGED SOME FEEDERS TO AL CONDUCTORS; SHOW GENERATOR AND ITS DIST BOARD AS ONE UNIT; ALL CHANGES ARE BUBBLED ON THE REVISED PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51694	12041-10000-23208	1342 N AVALON BLVD	90744	15	036B205  1260	7422005032	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	10/18/2012 12:00:00 AM	ADDRESS	33.79019	-118.26301	T.I. into an retail space- in an existing commercial building, combine 4 tenant spaces into 1 tenant space..  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51695	14041-20000-16681	16436 W TULSA ST	91344	12	210B137   905	2680012019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.2682	-118.49056	4.33KW PV1 roof-mounted system with (17) Trina Solar TSM-255 modules, and Solaredge P300 optimizers, and 1 Solaredge SE3800A-US transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51696	15041-20000-20774	345 E 51ST ST	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	33.99665	-118.26853	Plan check for Title 24 only. Project site is a park. Project scope is outdoor lighing. Total outdoor lighting area = 17, 067 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51697	13041-10000-24368	3470 W 6TH ST UNIT 2B	90005	10	135B197  1033	5502029026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM			PC Approved	09/06/2013 12:00:00 AM	PIN	34.06333997	-118.29761911	Change of use from retail to restaurant (920 sq. ft.) and interior tenant improvement.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51698	14041-20000-16183	300 S GRAND AVE Retail-Level	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Info Complete	06/17/2014 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for energy only. Ground floor/retail level bathroom and exit corridor renovation, new lighting (incl. emergency).  48-story (approx.) high rise building. ~900sqft (corridor sqft not inlcuded on form).Permit under separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51699	14041-20000-01903	16609 W VENTURA BLVD	91436	5	168B137   293	2259012018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.1581	-118.49489	PC FOR T24 ENERGY ONLY. TOTAL AREA 4538 SQ FT. NEW LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51700	14041-20000-33482	6320 N TOPANGA CANYON BLVD UNIT 1640	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.18578	-118.60536	New 1-story building for a restaurant.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy. Part of westfield village project. this is TI. Il Fornario	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51701	12041-10000-17319	8944 N FULLBRIGHT AVE	91311	12	195B113    38	2781001023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.23337	-118.57739	New 800A service, subpanels, transformers and lighting.  Shell only, no loads other than lighting.  Each new tennant will have to submit for plan review.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51702	16041-10000-42392	311 N GAFFEY ST	90731	15	018B197   703	7447031039	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	33.74529	-118.29249	SCOPE INCLUDES CHANGING FIXTURE TYPE AND LAYOUT IN A GAS STATION CANOPY AND IN THE STORE. ORIGINAL PERMIT IS UNDER 15041-10000-33890. PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51703	14041-10000-09408	9923 N EL DORADO AVE	91331	7	201B161   206	2624004032	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.25049	-118.4087	PV1 3.75KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(15)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51704	18041-10000-39625	18000 W CHATSWORTH ST	91344	12	207B125   637	2731008023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.26475	-118.52434	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51705	16041-20000-27515	1451 E 4TH ST	90033	14	127-5A219 339	5172020009	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.04249	-118.22532	Plan check Power and energy in existing building existing panels core and shell  load exceed 400A. Total area: 35,718 sq ft.Building permit filed under 15016-20000-25915.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51706	13041-10000-03727	661 S IMPERIAL ST	90021	14	124-5A217 146	5164020003	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.03599	-118.2315	PROPOSED TENANT IMPROVEMENT FOR 7,500 S.F. RETAIL GROCERY STORE.   CHANGE OF USE FROM MANUFACTURING TO MARKET/RESTAURANT w/ 7 SEATS (INDOOR ONLY).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51707	13041-20000-22655	1907 S CORNING ST	90034	10	126B169   431	4302028009	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	34.04288	-118.37988	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW USING TOTAL OF 16 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51708	18041-10000-19828	425 S SOTO ST	90033	14	126A223    76	5183014036	C2-1-CUGU, P-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.0398	-118.21254	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51709	17041-20001-22175	4513 N TYRONE AVE	91423	4	168B153   794	2265016063	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	07/12/2017 12:00:00 AM	ADDRESS	34.15347	-118.44452	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.7 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51710	15041-20000-30532	601 S FIGUEROA ST Suite 4400	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.05076	-118.25881	Title-24 plan check only.  Total area = 1,570 sq. ft.   T.I. to existing commercial highrise office space.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51711	17041-20002-31524	15060 W VENTURA BLVD #150	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.15287	-118.46147	9.25.2017 - Plan check for modifications to approved set. Update plans to show more detail per inspectors request. Overall lighting design has not changed (T24 calculations remain accurate). Provide/show daylighting controls.======Commercial TI - new partitions and modifications to (E) lighting system.  Title 24 plan check for energy only.  Permit under 17041-20000-31524.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51712	15041-20000-22889	5338 N CARTWRIGHT AVE	91601	2	171B177   202	2416027004	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			07/17/2015 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.16776	-118.36304	Plan check for 21 units apartment with 800A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51713	18041-20000-39894	5240 N DAHLIA DR	90041	14	163-5A227 153	5669011029	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.14272	-118.19971	pv1install roof mounted pv system sized 5KW AC interconnected with msp.(2) tesla Battery back up system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51714	18041-20000-19203	10537 W SANTA MONICA BLVD Ste. 220	90025	5	132B157   951	4326033041	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.05512	-118.42802	Tenant improvement combining two office spaces on the second floor - relocating existing lighting fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51715	11041-20000-13003	825 W COLORADO BLVD 1ST FLR	90041	14	163-5A231 142	5709002012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.1404	-118.18419	Plan check for T24 Energy. Install 2 new light fixtures and relocate 2 light fixtures on existing ckts for office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51716	12041-10000-00632	808 W 58TH ST	90037	9	108B197  1393	5001015032	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	33.98934	-118.28723	PLAN CHECK POWER REPLACING 600A SERVICE WITH NEW 800A SERVICE FOR MEDICAL OFFICE. INSTALLATION WILL USE EXISTING SERVICE DROP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51717	15041-20000-12906	7665 N VICKY AVE	91304	12	189B097  1173	2013031009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.2102	-118.61976	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel(20) Sunpower SPR 327 Modules(1) Sunpower SPR 6002 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51718	18041-20000-36970	12915 N TITIAN AVE	91344	12	222B133   260	2602016004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.30518	-118.50684	Plan check for PV roof mounted system, system size: 5.12KW DC, 4.574KW AC with 16 PV Modules and 16 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51719	14041-20001-10527	17022 W HARTSOOK ST	91316	5	171B133   447	2258023030	RE9-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.16395	-118.50412	Derating of main panel breaker from 200Amp to 150Amp - main panel is center fed.NO FEE DUE TO 2012 STATE SENATE BILL 1222[[[PV1 SINGLE FAMILY DWELLLING. TOTAL SYSTEM SIZE 7KW AC USING 3 STRINGS. 21 MODULES.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51720	16041-10000-28901	7324 W APPERSON ST	91042	7	204B197   861	2558021032	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.25579	-118.29209	Plan check for T-24 only.  Remove outdoor HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51721	13041-20000-05123	7800 N WOODLEY AVE	91406	6	189B141   290	2206009901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM			Reviewed by Supervisor	03/04/2013 12:00:00 AM	ADDRESS	34.21161	-118.48344	Installing new feeders and losds in excess of 400 amperes to existing service equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51722	14041-20000-17722	930 S HILGARD AVE	90024	5	135B153   504	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Info Complete	10/24/2014 12:00:00 AM	ADDRESS	34.06306	-118.44116	Remodel of guest rooms for existing highrise hotel.  Revised load greater than 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51723	17041-10000-18166	1399 S ROXBURY DR	90035	5	132A165   329	4330005046	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.05409	-118.40253	Plan check for Title 24 only in existing space T.I. Total area: 108 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51724	13041-20000-31511	800 W WILSHIRE BLVD Suite 1400	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.0493	-118.25841	T42 FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON SUITE 1400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51725	18041-10000-12024	2501 W SUNSET BLVD C-D	90026	13	141A205   271	5402015026	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1956.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.07974	-118.26907	PLAN CHECK FOR TITLE 24 ONLY FOR TI (Change of use from retail (existing tenant spaces C - D) to day care with one classroom). TOTAL AFFECTED AREA = 3785 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51726	18041-20000-36424	20436 W ESMERELDA LANE	91326	12	216B109   208	2701082009	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.29091	-118.57931	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (2) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51727	19041-20001-46461	4821 N OAK PARK AVE	91316	5	168B133   194	2289004011	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.1584	-118.50467	$0 plan check fee  due to SB1222 and AB1414supplemental plan check only, for change to approved set, change to single line, change to which main panel breaker ac disconnect connects to. clouded change only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51728	13041-20000-17388	13360 W DEBBY ST	91401	2	177B157   308	2330005007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	ADDRESS	34.18382	-118.42459	New microinverter PV, for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51729	18041-30001-35561	350 S GRAND AVE 18TH FL.	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	01/15/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3 and Delta 4. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.*****Original Scope of Work*****PLAN CHECK FOR T24 ONLY,  TENANT IMPROVEMENT WORK ON +/- 12,295 SQFT. OF THE EXISTING 18TH FLOOR SUITE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51730	19041-20000-33988	13517 W BAYLISS ROAD	90049	11	138B133   344	4492014019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	34.07375	-118.50495	PV1. INSTALL 7.75 KW DC SOLAR SYSTEM WITH (25) ROOF MOUNTED MODULES AND MICROINVERTERS (ENPHASE IQ-7-60-2-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51731	19041-10000-35540	4209 S WESTERN AVE	90062	8	114B193  1033	5021028002	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	06/27/2023 12:00:00 AM	ADDRESS	34.00692	-118.3092	FULL PC FOR POWER AND ENERGY FOR A NEW SCOPE OF WORK INCLUDES A NEW 600A SERVICE 120/240 3P 4W. FEEDING A 600A HOUSE AND DISTRIBTION BOARD THAT FEEDS TWO HOUSE PANELS, ELEVATOR. THE 600A DISTRIBUTION BOARD ALSO FEEDS A 600A METERING BOARD THAT FEEDS THE 25 SUB PANELS. TOTAL AFFECTED AREA IS 5575 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51732	10041-20000-23408	17642 W SHERMAN WAY	91406	12	183B129   161	2228022003	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.20092	-118.5178	Plan check new roof mounted 25.4 KW P.V. system. and install 250A rated main breaker pull section.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51733	19041-20001-46903	22624 W WATERBURY ST	91364	3	165B097   370	2078006024	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.14872	-118.61871	$0 Plan check fee due to SB1222 and AB1414.Supplemental plan check only for changes to approved set. Clouded changes only. Change to single line, cover page, signage page, and roof layout page. Removal of ac disconnect and performance meter. Also changed main panel bus rating and main circuit breaker size. Changes made to wire chart, wire calcs, and item schedule.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51734	19041-10000-03993	8500 W BURTON WAY 1-88	90048	5	138B173  1128	4334016087	(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			Not Ready to Issue	02/01/2019 12:00:00 AM	ADDRESS	34.07095	-118.37677	Plan check for T24 only to (E) express permit#18041-10000-28949 for existing trader Joes. area of scope 13,895 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51735	19041-10000-46852	4018 S BUCKINGHAM ROAD	90008	10	117B181  1088	5032004909	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			11/14/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	01/29/2021 12:00:00 AM	ADDRESS	34.0139	-118.34221	EXPEDITED PER APPLICANT REQUEST. PLAN CHECK FOR A NEW FIRE ALARM WHICH CONSISTS OF 1 FACP, 1 COMMUNICATOR, 1 ANNUNCIATOR, 5 POWER SUPPLIES AND 260 DEVICES. (100% AFFORDABLE HOUSING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51736	16041-20000-07065	21700 W OXNARD ST SUITE 130	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.17901	-118.60179	(E) bank remodel with all new lighting system.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51737	14041-20000-15277	11243 N NORRIS AVE	91331	7	210B157   149	2534003011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.2743	-118.42068	PV1Install roof mounted solar array on SFD, microinverter system. System size: 4.3kW(20) EnPhase M215 microinverters(20) Canadian Solar CS6P 250P pv modulesNew panel upgrade under separate permit	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51738	18041-20000-37378	7701 N WOODLEY AVE	91406	6	186B137   423	2205010905	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.20948	-118.48389	Plan check for power only. Project site is an existing commercial building (existing hangar at Van Nuys airport). Project scope is a new 800 amp serive at 4.8KV feeding a 2,000-amp switchgear which will re-feed existing distribution equipment and loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51739	13041-10000-35322	2049 S CENTURY PARK EAST 9TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLANCHECK AND PERMIT FOR T24 ENERGY ONLY. HIGHRISE OFFICES. 9TH FLOOR. 23083 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51740	11041-20000-14206	15230 W VANOWEN ST	91405	6	180B145    39	2235004009	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.19371	-118.46506	New Bakery for an existing Fresh & Easy store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51741	13041-10000-14457	8515 N PENFIELD AVE	91306	3	192B113   169	2782011034		North Valley				1134.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.22501	-118.56907	PV1.  Installation of a 13.72 kW DC roof-mounted array, interconnect into existing main service panel.  {Central inverters: two Kaco 5002XI and one 2502XI}  { 56 modules: EcoSolargy Orion Series ECO245A156P-60}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51742	12041-10000-27083	7923 N GLORIA AVE	91406	6	189B141    99	2206007034	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00, 1275.10	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	34.21451	-118.47946	"CONVERT PORTION OF EXIST. WAREHOUSE/OFFICE TO PACKAGING EDIBLE OIL, ""FOOD PRODUCTS MFG"". EPC IS FOR POWER AND ENERGY T24. (no classified area)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51743	19041-20000-33904	1621 N MCCADDEN PL	90028	13	148-5A185 221	5547013006	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM	07/14/2020 12:00:00 AM		Permit Finaled	12/31/2022 12:00:00 AM	ADDRESS	34.10036	-118.33708	Plan check for power and energy for new 8 story 69-unit multi-family building. 2000A 208/120 Volts 3 phase Fire Pump. B#18010-10000-06223Note: appliant has pre-cut check, additional fees shall be paid under submittal 2 total of $1669.01 .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51744	14041-10000-00419	6544 W HOLLYWOOD BLVD	90028	13	148-5A187 185	5547015018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.10142	-118.33267	T24 PART 6 ENERGY FOR (E) RETAIL 2 BUILDING STORY. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 7825 SQ FT. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51745	14041-10000-17628	742 W CHANNEL ST	90731	15	021B197   367	7445008034	M1-1VL	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	33.75392	-118.29334	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 1468 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51746	13041-10000-28239	1816 N SAN JACINTO ST	90026	13	145-5A205 279	5431032020	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM			Not Ready to Issue	10/10/2013 12:00:00 AM	ADDRESS	34.09239	-118.2695	PV1 2.1KWAC 240V MICROINV 2STORY. STD. ROOFMOUNT.[( 10) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: SOLARTECH ENERGY CORP.SEC-6P-60-240]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51747	15041-20000-04105	9530 N COZYCROFT AVE	91311	12	201B109   341	2748003084	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Issued	05/29/2015 12:00:00 AM	ADDRESS	34.24346	-118.58186	PLANCHECK FOR POWER. SERVICE UPGRADE TO 277/480 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51748	16041-20000-29380	7858 W DENIVELLE ROAD	91040	7	210B193   241	2552013012	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM			Reviewed by Supervisor	08/30/2016 12:00:00 AM	ADDRESS	34.27226	-118.30459	PV1.  Install 15.2 kW roof mounted utility interactive PV system.  (55) modules with (2) SolarEdge 7600 W inverters with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51749	17041-20000-17160	320 E SUNSET AVE	90291	11	109-5A143  83	4286007031	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	33.99526	-118.47456	Plan check for energy only. Addition to existing restaurant of new covered patio space to be used for dining. New lighting - 852sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51750	11041-20000-21845	8746 N CANBY AVE	91325	12	195B125   699	2769025023	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.23002	-118.53466	Existing building.  Building used to be a private school and is being converted to a rescue mission.  New switchboard, panels, lighting, etc.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51751	19041-20000-25322	10900 W WILSHIRE BLVD ste 350	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	02/04/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.05848	-118.44419	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51752	15041-10001-37205	2122 W 7TH ST	90057	1	132A203    83	5141018004	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.0567	-118.27768	changes to approved set of plans. changes include relocation of some lights. change in lighting type. changes noted delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51753	15041-10001-14924	9511 N HATILLO AVE	91311	12	198B113    32	2761029009	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	34.24322	-118.56617	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 7.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (22) MODULES: SUNPOWER SPR327NE-WHT-D (1) INVERTER: ABB-PVI-6000-OUTD-US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51754	16041-10000-22094	1153 S SANTEE ST FLR 1	90015	14	124-5A209  66	5145021028	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.03654	-118.25728	T-24, PC FOR AN EXISTING COMMERCIAL BUILDING ON THE 1ST FLOOR LOBBY AREA. TOTAL AFFECTED IS 286 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51755	19041-10001-42960	6471 W 84TH ST	90045	11	096B165    16	4108011016	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM			PC Approved	11/08/2019 12:00:00 AM	ADDRESS	33.96304	-118.40161	NEW ROOF MOUNTED 6.3 (DC) KW, WITH 17 SOLAR MODULES AND A POWER WALL BATTERY SYSTEM ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51756	15041-10000-35937	10101 W WILSHIRE BLVD South-Course	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.06725	-118.41704	Plan check for a medium  voltage project, 4.16KV. Scope includes new substation distribution, and equipment for existing country club. Existing DWPservice located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51757	10041-10000-08357	1277 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.05114	-118.22554	PV system for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51758	19041-30000-31452	11835 W OLYMPIC BLVD 10th floor	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.03301	-118.45119	tenant improvement to corridor on the 10th floor title 24 only. total area 1,684 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51759	14041-10001-21294	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016023	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.08758	-118.34425	Modifications to approved set.  Change of # and model of power supplies, changes to NAC wiring configurations, and duct smoke detectors added.  (((Installation of a complete, non high rise, code minimum, addressable fire alarm system.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51760	16041-10000-00085	5432 S WILTON PL	90062	8	108B189   782	5005016011	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Expired	02/02/2018 12:00:00 AM	ADDRESS	33.99224	-118.3148	PV1, rooftop solar installation 3kW AC(15) KU25556XPA(1) PVI-3.0-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51761	13041-10001-30297	20419 W DEVONSHIRE ST	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Approved	09/03/2014 12:00:00 AM	ADDRESS	34.25742	-118.57823	(((9/3/2014- CHANGES MADE TO APPROVED SET. REVISED TRACK LIGHTING ON LTG FORMS. T24 CALCULATIONS TO BE VERIFIED)))PLAN CHECK FOR POWER AND ENERGY FOR TI OF EXISTING RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51762	17041-10000-20076	360 E 2ND ST #374	90012	14	129A215   149	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	Title 24 plan check.  T.I. to existing retail.  Combine 3 suites into 1.  3 new subpanels with lighting and receptacles.  Total area = 3,496 sq. ft.       Building permit #17016-20000-12220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51763	17041-20001-00128	1200 N BEL-AIR ROAD	90077	5	147A153   602	4370029013	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.09497	-118.44366	Recheck of lost set of plans.  (((New three story SFD with 208Y/120V 1600A service.  Plan check for power only.  Electrical permit issued under building combination permit 14010-30000-02037.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51764	19041-10000-01894	12885 W FOOTHILL BLVD	91342	7	219B161   287	2514003043	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Issued	01/16/2019 12:00:00 AM	ADDRESS	34.29394	-118.41539	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51765	10041-20000-21643	7317 N RESEDA BLVD	91335	3	186B125   819	2118015009	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	34.20355	-118.53632	lost plans permit is 50 % of the original by doug verral	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51766	15041-10000-35920	6767 W SUNSET BLVD phase I	90028	13	147A185    57	5547020041	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.09814	-118.33821	INSTALLATION OF LED ACCENT VANITY LUMINAIRES IN CLASSROOMS AND LOUNGE AT A MUSIC SCHOOL. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51767	17041-20003-14641	4161 N FARMDALE AVE	91604	2	162B169    52	2368022016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.14418	-118.38128	[[12/15/17 CHANGES TO APPRVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. ADDITION OF DISCONNECT TO THE ENERGY STORAGE ]]]]Additional subpanel and disconnect.  ((Plan check for the addition of a PV1 roof-mounted PV system and a Tesla AC Powerwall to an existing PV system. PV system addition size is 3 kWac and consists of (1) inverter, (8) modules, and (1) load center. Tesla AC Powerwall rating is 7 kWac.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51768	16041-20000-06636	13724 W ALMETZ ST	91342	7	231B153    32	2582008009	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.32717	-118.43257	PV1.ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51769	15041-20000-01857	7509 N WOODLEY AVE	91406	6	186B141   265	2205022002	[T][Q]MR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.20687	-118.48387	REVISIONS TO AN APPROVED SET OF PLANS.  DOWNSIZE NUMBER OF MODULES FROM 18 TO 11 SOLARWORLD 270WATTS.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(18) SOLAR WORLD SW 270 MODULES(18) ENPHASE M-215 MICROINVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51770	16041-10001-17115	18427 W NORDHOFF ST Unit C	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.23565	-118.53484	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE REVISED FIXTURE SCHEDULE TO MATCH AS BUILT. UPDATING MANUFACTURER ON FIXTURES. NO CHANGE IN WATTAGE AND LAYOUT. T24 DOCUMENTS REMAIN THE SAME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51771	14041-20000-25101	8500 W BEVERLY BLVD #618	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Issued	09/18/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI to (E) commercial retail space in shopping center.  Plan check for energy per 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51772	18041-10001-25534	4204 S EAST BLVD	90066	11	111B157   473	4233007027	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.00077	-118.42008	EXPEDITE PER APPLICANT REQUEST.((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.91KWdc / 11.76KWac(42)MODULES-LG NEON R 355(42)MICROINVERTERS-ENPHASE IQ6PLUS-72	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51773	15041-10000-18140	1063 S WOOSTER ST	90035	5	132B169   422	4332016034	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			06/11/2015 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	11/30/2021 12:00:00 AM	ADDRESS	34.05743	-118.38271	Full plan check for a new 4-story 8-units apartment building over basement located in a methane zone; main scope includes a 600-Amp 3-phse 4-wires services and (10) other panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51774	12041-10000-10952	3616 S TROUSDALE PKWY	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/15/2012 12:00:00 AM	07/06/2012 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.01983	-118.28534	PLAN CHECK POWER AND ENERGY FOR OUTDOOR LIGHTING INSTALLATION FOR USC HAHN PLAZA HARDSCAPE. POWER SUPPLING FROM AHF BUILDING. SITE LOCATED IN METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51775	10041-10000-01359	1884 E 22ND ST	90058	14	117A215     6	5167006021	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Finaled	03/09/2010 12:00:00 AM	ADDRESS	34.0169	-118.23653	Tenant improvement for existing industrial building.  Install new general lighting in cooler areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51776	15041-20000-29753	22819 W MULHOLLAND DR	91364	3	165B097   156	2076013028	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.15094	-118.62394	Installation of new roof mounted solar PV array.  Total system size = 7.7 kWac. standard plan Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51777	12041-10001-05705	8575 W 3RD ST Parking #4	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.07372	-118.37914	Supplemental plan check for two new branch circuits for emergency lighting ELP panel. T-24 and emergency lighting plan check canopy and parking area of Parking structure #4 approved under #12041-10000-05705.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51778	13041-20000-09106	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	33.96577	-118.42406	Install new high voltage supply for sports field lighting.  Lighting is three phase.  Site is a Methane Zone.  12 month peak demand, metering report signed by engineer of record of the plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51779	19041-10000-53812	13202 S ESTRELLA AVE	90248	15	078B201    24	6132003015	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Issued	12/31/2019 12:00:00 AM	ADDRESS	33.91311	-118.28575	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51780	12041-10000-24678	3620 S MCCLINTOCK AVE	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.0213	-118.28935	REPLACE 2 EA 5KV 600A VACUUM SWITCHES CONNECTED TO PARALLEL FEEDERS TO EXISTING DUAL SWITHBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51781	15041-10000-21382	1234 S ELDEN AVE	90006	1	129B197   932	5076017007	R3-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2015 12:00:00 AM			Verifications in Progress	08/14/2015 12:00:00 AM	ADDRESS	34.04809	-118.28756	PV 1 ROOF MOUNTED SYSTEM. TOTAL SIZE 10.08 KW, 36 PANELS AND 2 INVERTERS. (36) LG280S1C-B3(1) ABB # PVI-5000-OUTD-US (1) ABB # PVI-3.6-OUTD(-S)-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51782	14041-20000-16737	15165 W VENTURA BLVD suite 425	91403	4	168B145   932	2264007010	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Expired	08/01/2016 12:00:00 AM	ADDRESS	34.15357	-118.46363	Plan check for energy only. Commercial high rise office remodel. All lights and circuits existing (lights relocated).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51783	16041-30000-15467	2121 S AVENUE OF THE STARS 26th Floor	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check for Title 24 only. Project site is a portion of the 26th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 230 sq. ft.Note: Building application has been created under 16016-30000-09928	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51784	17041-10000-45739	18625 W SUPERIOR ST	91324	12	201B121   469	2763033021	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	09/08/2018 12:00:00 AM	ADDRESS	34.24636	-118.5392	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 12.54KW(DC)/ 12KW(AC)SCOPE INCLUDES 44 MODULES WITH OPTIMIZERS AND SINGLE CENTRAL INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51785	19041-20000-01538	9533 N FULLBRIGHT AVE	91311	12	201B113   967	2748019034	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.24387	-118.57755	PV1.  Install 10.73 kW DC / 10 kW AC roof mounted grid tied PV system.  (37) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51786	10041-10000-23221	1925 S CENTURY PARK EAST 13th Floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI in an existing commercial building on th 13th Floor. EPC is for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51787	13041-10000-32988	17212 W LITHUANIA PL	91344	12	219B133   302	2608020023	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.29795	-118.50804	PV1, Install  5.5 kw DC roof-mounted solar array for a one story house, interconnect with the main service panel. (1)Transformerless inverter(s): SolarEdge SE5000A-US. (22)modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51788	10041-10000-25134	5715 N VAN NUYS BLVD	91411	4	174B149   525	2244028022	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM			Corrections Issued	12/28/2010 12:00:00 AM	PIN	34.17438287	-118.44919375	REMODEL EXISTING CAR DEALERSHIP - REMODELING INTERIOR W/EXTERIOR FACELIFT AND ADDITION OF OFFICE/SERVICE AREA AND STORAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51789	18041-20000-14837	20626 W WALNUT CIR	91326	12	219B109   358	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.29377	-118.58334	PC for rooftop solar for 3.84kW(ac)/4.02kW(dc) for SFD tract home. Installing 12 AC modules with AC disconnect.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51790	17041-10000-06225	2029 S CENTURY PARK EAST 31th FL-CORRIDOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Issued	03/07/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY ONLY (ALTERATION) . INTERIOR RENOVATION OF PUBLIC LOBBY ON THE 31TH FLOOR, CORRIDOR . EMERGENCY LIGHT IS NOT IN SCOPE.  AFFECTED AREA 3110 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51791	15041-10000-38215	801 S OLIVE ST	90014	14	127-5A209  31	5144019026	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			11/12/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.04514	-118.25715	New fire alarm system for a  new HIGH RISE 33-story (including 4-level parking above grade ) mix used apartment building with (363) units . Scope includes (2) fire alarm panels, (7) communication panels, (11) control panels and (1316) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51792	16041-10001-22643	7760 N YARMOUTH AVE	91335	12	189B129  1072	2120001014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM			PC Approved	07/20/2016 12:00:00 AM	ADDRESS	34.21178	-118.51953	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<<PV1, INSTALL NEW  12.426 KWDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(38) MODULES:  SUNPOWER SPR327NE-WHT(2) INVERTERS: SMA SB7700TL-US-22 AND SB3800>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51793	13041-10001-33039	13131 MESA VERDE WAY	0	7	225B165		RD6-1, Q					1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM				Expedited RSES plan check per applicant request.[][][]PV1, Install 6.5 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (26) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51794	13041-10000-04778	10050 W CONSTELLATION BLVD	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.05912	-118.41472	PC POWER & ENERGY. 1ST time TENANT.  use is ANNENBURG STUDIOS (PHOTOGRAPher ASSEMBLY - they assemble and discuss photos). applicant said that it was raw space before.CHANGE OF USE OFFICE TO ART STUDIO. INTERIOR T.I. - ADD NEW NON-BEARING PARTITIONS, RESTROOMS, MILLWORK, FINISHES,  AND CEILINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51795	13041-10000-21825	13645 W RIVERSIDE DR MAINT.BLDG	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.15777	-118.43065	New fire alarm system for Notre Dame High School maintenance building.  13 devices and one new fire alarm control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51796	15041-20000-41304	11568 W ARCHWOOD ST	91606	2	180B169  1361	2320024030		South Valley				1232.05	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.19204	-118.38414	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (24)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51797	15041-10001-35960	262 S VAN NESS AVE	90004	4	135B189   154	5516010012	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.06926	-118.31542	EXPEDITED PER CUSTOMER'S REQUEST, TROUBLE WITH ONLINE SYSTEM.(((PV1, ROOF MOUNTED SOLAR SYSTEM, TOTAL SIZW IS 6KW. (22) MODULES AND (1) INVERTER. (22)SUNPOWER 327W MODULES TOTAL. (1)POWER ONE-6000-OUTD-US-A)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51798	16041-10002-41570	1625 W OLYMPIC BLVD 9TH FLR	90015	1	130-5A203 305	5137002033	C2-2D, C4-2D	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM			PC Approved	08/14/2017 12:00:00 AM	ADDRESS	34.04973	-118.27494	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO GENERATOR CIRCUIT FOR EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51799	12041-10000-14265	12250 W MORRISON ST	91607	5	168B165   116	2356011008	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.16021	-118.40038	New photovoltaic system on the rooftop of an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51800	13041-20000-34234	11766 N PRESTON TRAILS AVE	91326	12	216B117   283	2822011011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.28597	-118.55854	Rooftop PV system for an existin sfr using Enphase microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51801	19041-20000-19992	1801 S CENTURY PARK EAST 24th-25th Flrs	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.06201	-118.41537	T24 ONLY PLAN CHECK FOR EXISTING HIGH RISE BLDG 24TH AND 25TH FLOOR LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 3170 SFBLDG PERMIT #19016-40000-05404	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51802	12041-10001-30650	380 W WORLD WAY #T60	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	12/15/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	First time tenant for airport concession space T60.  Power plan check, title 24 plan check already performed.  New 100A panel and associated wiring.   Original Work Description: T.I.  Remodel for airport concession space # T60.  Plan check is for Title 24 only using the Tailored Method.  Applicant wanted to have the T-24 plan check as back room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51803	16041-10000-26464	10908 N JAMIE AVE	91331	7	210B165   524	2536022001	RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.2682	-118.40455	Install new PV1 rooftop solar on SFD, 7.6 kW AC system.  (22) modules  (1) SE 7600A-US, using SEP 300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51804	11041-10000-18729	1525 W PIZARRO ST	90026	13	136-5A207 313	5159021027	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	34.06684	-118.261	title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51805	15041-20002-29952	555 S MATEO ST	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Closed	10/26/2017 12:00:00 AM	ADDRESS	34.03943	-118.23302	[[3-20-17  CHANGES TO APPROVED SET. DELTA 5 TO DELTA 10 CHANGES. PLANS ARE UPDATED PER INSPECTORS INSTRUCTIONS. CHANGES ARE CLOUDED. CHANGES TO SINGLE LINE, PANEL SCHEDULES AND SERVICE EQUIPMENT LOCATIONS. NEW BATHROOMS ADDED,  CHANGES TO LIGHTING]] 05-24-16 Changes to an approved set of plans. Changes include relocated service location and service single line diagram. Changes apply to delta 4 only. *************Previous work description*********************************Plan check for power and Title-24 (energy).  Total area = 119,893 sq. ft. (indoor) + 43,000 sq. ft. (outdoor)    New 3 story commercial building with 5,000 amp, 480/277 volt service.  Buildings labeled 1, 2, 3, and 4 on plans are connected structurally.  Plan checker to verify fees (applicant used pre-cut check).  Energy fees to be included on submittal 2 (per EM).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51806	13041-10000-22883	13361 N GLENOAKS BLVD BLDG B	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.3146	-118.45921	][][]FILE ALARM VARIANCES WILL BE FILED FOR THIS PC APPLICATION][][][]NEW HIGH SCHOOL BUILDING ADDITIONS ( 2 TOTAL- EACH HAS 27,354 SF & IS A REPLICATE OF THE OTHER) . FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW CHARTER HIGH SCHOOL. THIS APPLICATION IS FOR BUILDING B.  SINCE BOTH BUILDINGS ARE EXACT DUPLICATES OF THE OTHER, FEES WILL BE CHARGED BASED ON HALF OF THE TOTAL FOR BUILDING B, AND THE OTHER HALF WILL BE BASED OFF BUILDING C.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51807	16041-10000-43033	1770 N HIGHLAND AVE	90028	13	150A185   358	5547002036	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.10363	-118.33849	TI OF EXIST DONUT SHOP TO NEW 7-ELEVEN STORE. revised lighting. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51808	17041-30000-09771	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.05979	-118.41671	Title 24 plan check.  T.I. to suite 250 of existing commercial office highrise.  Two new subpanels with new lighting and receptacle loads.  Total area = 7,620 sq. ft.Building permit #17016-10000-02186	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51809	19041-20000-50718	844 S BROADWAY	90014	14	127-5A209 204	5144016060	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.04265	-118.25551	Plan check for Title 24 Energy only. for new lighting. Total area: 1432 sq ftB#19016-10000-18353	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51810	15041-10001-05063	8368 W 3RD ST	90048	5	138B173   844	5511031023	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.07279	-118.37236	Minor modifications to approved set and restamp to accommodate loss of originally approved plans.  (((Plan check for T-24 only. interior T.I. for a retail store. Total area: 809 sq ft. Isnpection Fees per applicant.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51811	13041-10000-22261	19948 W MAYALL ST	91311	12	204B113   502	2726002029	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.25351	-118.56831	FO PV1 10.045KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-3.6-OUTD-US and PVI-4.2-OUTD-US] [( 41) MOD: TRINA {TSM-245PC05.18}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51812	14041-10000-27867	730 N SAN FERNANDO ROAD	90065	1	144A219   114	5453007024	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.09012	-118.22683	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS.  947 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51813	18041-20001-01782	505 W CENTURY BLVD	90044	8	091-5A201  99	6054021017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM			PC Approved	06/17/2019 12:00:00 AM	ADDRESS	33.9457	-118.28312	6/17/2019changes to an approved set of plans.  changes to electrical layout and lighting design. this is plan check only.  (((((new single story commercial building (7 eleven) 800 amp service.  plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51814	18041-20000-28385	7261 W ESTEPA DR	91042	7	198B197    85	2562020015	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.2426	-118.29107	Plan check for PV roof mounted system, System size: 14.19kW with 43 pv modules and 43 microinverters.Permit fees $ 61.53 due to California Senate Bill 1222 and Assembly Bill 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51815	13041-20000-06297	5900 W WILSHIRE BLVD 20th FLoor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Info Complete	03/11/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for energy and emergency lighting. 20th Floor of Commercial High-rise	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51816	19041-20000-18475	17655 W DEVONSHIRE ST	91325	12	204B129    58	2733013009	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.25781	-118.51928	new 200 amp distribution board fed from MS to refeed existing panels A and B.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51817	19041-10000-41409	7011 N PARK MANOR AVE	91605	2	183B157   497	2328021016	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.19749	-118.42399	[E-PLAN] PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 35 MODULES (SUNPOWER 320) WITH 35 MICROINVERTERS (ENPHASE IQ7X). SYSTEM SIZE IS 11.2 KWdc AND 11.03KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51818	16041-20000-23621	765 E PALMS BLVD	90291	1	108B145   572	4241011035	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.99374	-118.46149	PV1INSTALL ROOF MOUNTED PV  SYSTEM SIZED 3KW, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51819	13041-20000-20238	2275 S PROSSER AVE PV-1	90064	5	129B157  1298	4320014020	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.04609	-118.42303	PV-1. 4752W AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51820	17041-10000-11455	523 W 6TH ST ST#830-840	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1570 SQ. FT. B#17016-10000-05522	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51821	11041-10001-16277	8333 N VAN NUYS BLVD	91402	6	192B149   303	2638038002	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM			PC Info Complete	01/25/2012 12:00:00 AM	ADDRESS	34.22236	-118.44896	T.I.  Existing Walmart.  Remodel of the lights and receptacles in the restrooms, 'vision center' and an unconditioned storage area and new loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51822	17041-10000-00940	22741 W VICTORY BLVD	91307	12	180B097   546	2038038021	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.18663	-118.6225	Plan check for power only install (1) 800A 277/4810V 3 phase 4 wires Service and (100A) Service equipment Underground	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51823	19041-20000-50270	110 E 9TH ST 3rd Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TI to commercial tenant spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51824	18041-20002-48713	10851 N BEE CYN	91311	12	207B101   586	2723005063	(T)(Q)RA-1-K, A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.26749	-118.60732	03-06-2019 Changes to an approved set of plans, Changes include update main panel to show 400A split bus 200A and 150 main disconnects. derate main breaker from 200A to 150A. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51825	18041-20000-47422	9122 N ORION AVE	91343	7	198B145   357	2656027067	R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Apartment			12/14/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.23623	-118.47182	Plan check for new fire alarm system for 14 units 3 story building. Totala fire alarm devices: 74 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51826	15041-10000-28096	4228 E VERDANT ST	90039	13	159B205   455	5594006029	[T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	34.1314	-118.26446	Full plan check for a NEW  TWO STORY CHURCH - SANCTUARY. building,  Scope includes (9) panels with (260) circuit fed by other building located at the same lot. Total area is 37,493-SQ feet for T24. Reference application # for 3000-Amp service panel: 15041-10000-28085.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51827	19041-10000-38442	6925 N GAZETTE AVE	91306	3	183B109   668	2137023005	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.19643	-118.58754	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10.3KVA  PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE7600H-US AND SE3000H-US) WITH 38 MODULES USING P400 OPTIMIZERS AND ESS(LGCHEM RESU10H 9.8KWH)      MAIN PANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51828	13041-10000-15086	1735 N LA BREA AVE 1-18	90046	4	147B181    80	5548001022	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Apartment			06/10/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.10267	-118.34589	FA R3-1 4 STORY OVER 2 LEVEL BASEMENT. 1 panel. 1 ann. 127 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51829	12041-10000-13960	618 S BROADWAY	90014	14	129A211   228	5144002020	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.04607	-118.25233	REPLACING AN EXISTING FIRE LIFE SAFETY SYSTEM IN THE BUILDING.  <<< COMPLY WITH DEPARTMENT ORDER effective date 07/08/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE>>> 23. new devices that are compatible with old system, plus one panel by silent knight.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51830	16041-10000-13872	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.01925	-118.37654	INTERIOR TI FOR OFFICE  1300 SQ. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51831	17041-20000-15251	22121 W CLARENDON ST	91367	3	174B101   404	2169026110	CR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Apartment			05/16/2017 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.16978	-118.60882	Plan check for power and energy. New 335-unit, 5-story apartment building. (2) 4000A services and (1) 3000A service. T24 area = 134,274sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51832	19041-20000-47652	1918 S ROXBURY DR	90035	5	129B165   803	4307014026	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Issued	12/11/2019 12:00:00 AM	ADDRESS	34.04739	-118.40124	PV1.  Install 20.3 kW roof mounted grid tied PV system.  (58) AC modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51833	13041-10000-20491	1888 CENTURY PARK EAST 20TH FLOOR	90067										Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM				TITLE 24 IN A HIGH-RISE BUILDING(20TH FLOOR). EMERGENCY LIGHTING WILL BE CONNECTED TO EXISTING EMERGENCY CKT. 4615 SF. SCOPE OF WORK IS LESS THAN 400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51834	18041-20000-10880	23001 W ROSCOE BLVD	91304	12	192B097   581	2005002901	A1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.21953	-118.62822	PLANCHECK FOR POWER ONLY. REPLACING EXISTING FEEDERS AND (2) UPS WITH NEW UPS STATIONS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51835	17041-10000-39619	727 N BROADWAY Suite 126	90012	1	133-5A215  39	5408021015	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	PIN	34.06159584	-118.23968606	PC for T24 only for new lighting in storage/office space. Installing new lights, receptacles and equipment. Total is 630sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51836	18041-10000-35851	6946 N VAN NUYS BLVD	91405	6	183B149   453	2217009902	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM			PC Approved	09/19/2018 12:00:00 AM	ADDRESS	34.19693	-118.44846	Energy plan check for (2) restroom T.I with a total area of 532-SQ FT. Permit is paid under 18041-70000-17008.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51837	19041-20000-16548	10550 W FONTENELLE WAY	90077	5	147B149   401	4370018030	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM			PC Approved	12/02/2019 12:00:00 AM	ADDRESS	34.09836	-118.44826	Distribution, power, and lighting for guest house permitted under 16010-10000-05214.  Note: Electrical permit fees have been paid under 16010-10000-05214. Guest house distribution is feeding off of the main SFD service. Service is 1,200 Amps and was reviewed under 17041-20000-20854.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51838	18041-20000-42938	11955 W LOSETO LANE	91352	6	195B165   880	2631021028	(T)(Q)R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Expired	08/24/2023 12:00:00 AM	ADDRESS	34.23374	-118.39326	PV1.  Install 3.96 kW roof mounted grid tied PV system. (12) modules with 3.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51839	12041-10000-21375	2002 S PENMAR AVE	90291	11	111B149  1443	4242019***	RD3-1XL	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	33.9999	-118.45479	3.43 KW ROOF-MOUNTED PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51840	17041-10000-19225	17101 W PLUMMER ST	91325	12	201B133     6	2692008007	(T)RA-1-H	North Valley	Northridge	Northridge East	Yes	1151.01	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.24317	-118.50558	PC for T24 for removal of 22 outdoor HID fixtures and replace with new led fixtures. Total sqft of 95250.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51841	17041-20000-46281	17722 W ORNA DR	91344	12	219B129   139	2601049019	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.29965	-118.52012	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. (E) solar system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51842	14041-20000-11426	5652 N VANTAGE AVE	91607	2	174B165   538	2340026044	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.17364	-118.3975	PV1.  Install 3.00 kW roof-mounted PV system, interconnect with main service panel.  (12) modules.  Transformerless inverter: SolarEdge SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51843	17041-20000-22125	11408 W SARAH ST	91602	2	168B173   980	2365013023	RD1.5-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Apartment			06/30/2017 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	PIN	34.15357905	-118.3793427	Plan check for power and energy. New 3-story, 10-unit apartment building, with parking garage and lobby on 1st floor (at grade). 800A 120/240V 3ph 4w service. Indoor T24 area = 7340sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51844	18041-20000-24986	11835 W OLYMPIC BLVD spec suite-695E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.03301	-118.45119	Plan check for Title 24 only in existing commercial office T.I. Total area: 1263 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51845	16041-10001-31733	269 S SAN PEDRO ST	90012	14	129A213   450	5161025***	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.0477	-118.2427	"Changes to approved set.  Remove subpanel ""C"" and relocated loads onto subpanel ""B"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51846	12041-10001-28671	16208 S VERMONT AVE	90247	15	069B197   287	6120017804	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	33.88408	-118.29119	INSTALL FUEL CELLS (1)ES-5400, (2) ES5700 & HARDWARE. 1200A MAIN     ((((((((((((((((    cHANGES MADE TO PREVIOUSLY APPROVED ADDITION OF TWO  XFORMERS AND TWO PANELS.   06-24-2014 MEDI ZANDI  ))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51847	18041-10000-02471	7035 N SOPHIA AVE	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.19852	-118.48711	REMOVE INDOOR / OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51848	13041-10001-31513	13841 N ELDRIDGE AVE	91342	7	228B157  1119	2503003005	(T)RE11-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.32351	-118.43219	Expedited RSES plan check per applicant.{{{PV1, Install 4.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 17 modules Trina Solar TSM-250PA05.18.(((NEW 2-STORY SINGLE FAMILY HOME WITH ATTACHED GARAGE.  2467 SF. PLAN 2 PER SMALL LOT SUBDIVSION TRACT 60341)))}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51849	19041-10001-02509	1800 S ROXBURY DR	90035	5	129B165   674	4307013019	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.04854	-118.40112	**fee expedited per applicant**New rooftop solar system on (E) SFD, (42) modules SOLARIA POWERXT-360 with power optimizer P400, (1) inverter SE 11.4 kW AC. System interconnect to 225A rated bus.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51850	17041-20000-23161	3376 N GLENDALE BLVD	90039	13	156B209   405	5436014001	[Q]C4-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.12	-118.25836	PLANCHECK FOR POWER AND ENERGY. PROPOSED 1 STORY COMMERCIAL RETAIL W/ MEZZ. 1135 SQFT.BUILDING PERMIT # 15010-10000-00327	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51851	13041-20001-20411	4540 N CHARMION LANE	91316	5	165B133    47	2290026019	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.15237	-118.51091	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 13 KW USING 44 MODULES. USING 2 CENTRAL INVERTERS WITH ISOLATION TRANSFORMER. NONSTANDARD PLAN. (((chnage in point of connection. plan check only for changes clouded))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51852	16041-10000-27778	5722 N TUJUNGA AVE	91601	2	174B173   533	2337037006	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.17469	-118.37885	Remove Indoor HID fixtures and replace  with new LED fixtures - plan check T/24 only. Total area 2708 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51853	13041-10001-30931	911 N ALFRED ST	90069	5	144B173   348	5529006074	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Verifications in Progress	12/18/2013 12:00:00 AM	ADDRESS	34.08737	-118.37541	Expedited RSES plan check per applicant request. (((PV1, Install 8.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US. 44 modules HANWHA # HSL60P6-PB-4-250TW.))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51854	14041-20000-17566	12324 W MOORPARK ST	91604	2	165B165   401	2367002021	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.15015	-118.40165	Fully sprinklered 3 story 8 unit apartment with basement garage.    New 800A service, panels, branch circuits, and lighting.  Plan check for power and energy.Note:  Per applicant, garage lighting/power floor plans and Title 24 calculations will be submitted within 3 days.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51855	17041-20001-03783	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			PC Approved	02/02/2018 12:00:00 AM	ADDRESS	34.30155	-118.46112	02/02/2018 Plan check for a lost set of plans. Scope of work has not changed.*****Previous Work Description*****ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 3366.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51856	17041-20000-20935	19343 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.18677	-118.55496	Plan check for energy only. TI to customer area of existing commercial retail space. New lighting. T24 area - 1,903sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51857	17041-20000-36052	2343 N RIVERDALE AVE	90031	13	144B213   440	5445018021	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.09135	-118.23453	Plan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.3kW unground pv system. (8) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each pv module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51858	12041-10000-25904	3900 E CHEVY CHASE DR	90039	4	159B205   748	5593002907	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Public Safety Only			10/29/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	03/18/2013 12:00:00 AM	ADDRESS	34.13327	-118.27281	New fire alarm system for a commercial Bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51859	17041-10000-29508	777 S SANTA FE AVE	90021	14	124-5A217 323	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.03354	-118.23024	PC FOR POWER ONLY FOR CORE AND SHELL UPGRADES. REUSING EXISTING BUILDING WITH SOME UPGRADES. SOME DISTRIBUTION EQUIPMENT TO REMAIN AND REBUILDING SOME NEW AS SHOWN ON PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51860	19041-20000-10292	5210 N HERMOSA AVE	90041	14	163-5A225 213	5669023013	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.14173	-118.20749	INSTALLATION OF A 5.4 KW DC/4.725KW AC ROOFTOP PVV SYSTEM FOR EXISTING SFD. SCOPE OF WORK TO INCLUDE (15) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND (2) 100A LOAD CENTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51861	17041-10000-24701	3855 W EVANS ST	90027	4	150B201   556	5433024004	R2-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.10791	-118.27529	Plan check for Title 24, remove Outdoor HID fixtures and replace wiht new LED  fixtures. Total area: 7,525  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51862	18041-20001-30959	4673-4683 W HOLLYWOOD BLVD	90027	4	147B197   304	5542001004	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.10096	-118.29101	07-29-2019 Changes to an approved set of plans, Changes include engineer of record, reduce scope of work in each tenant(lighting, power and service load calculation), layout on floor plan, service and panel board AIC ratting and service relocation. Plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51863	14041-10001-04979	4208 DUNDEE DR	90027	4									Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM				EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE5000A-US-ZB-U(18) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51864	18041-20000-04870	1471 E VERNON AVE	90011	9	112-5A211  57	5116007024	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.0041	-118.24803	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51865	19041-20001-03113	6411 N SEPULVEDA BLVD 2A	91411	6	180B145   763	2234016013	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.18729	-118.46647	Additional circuits for lighting and power for retail TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51866	19041-10000-48634	1828 E CESAR E CHAVEZ AVE #404	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	02/21/2020 12:00:00 AM		Permit Finaled	07/09/2020 12:00:00 AM	ADDRESS	34.05014	-118.21571	FULL PLAN CHECK FOR A SERVICE OF 1000 AMPS, 480/277 V, 3 PHASE 4 WIRE SYSTEM. SCOPE INCLUDES AN EXISTING SPACE WITH  AN ADDITION FOR 1 NEW PANEL INCLUDING RECEPTACLES, LIGHTING, AND CONTROLS CONNECTED TO THE EXISTING SYSTEM. TOTAL AFFECTED AREA: 3680 SQ FTPER BUILDING PERMIT #19016-20000-29914	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51867	18041-10000-40399	3035 N ANDRITA ST	90065	13	154-5A213 157	5458007801	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.11644	-118.24583	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51868	19041-10000-42193	631 E FLORENCE AVE	90001	9	102B205   745	6007019008	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	33.9749	-118.26414	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51869	13041-20000-31266	10526 W DUBNOFF WAY BLDG A	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.18656	-118.36106	PC FOR POWER. NEW 1600A SERVICE AND DISTRIBUTION. BUILDING A OF SERIESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51870	10041-20000-11999	915 W WILSHIRE BLVD 2175	90017	9	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.05069	-118.2599	energy plan chek # 2175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51871	18041-10000-01231	321 E G ST	90744	15	030B209   326	7423012044	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	33.77883	-118.25885	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51872	16041-10002-12995	419 S SPRING ST	90013	14	129A211    54	5149024027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	34.04843	-118.24885	Supplemental PC for relocated switchgear from basement to first floor and removal of temporary fire pump. All changes clouded under delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51873	16041-10001-15287	2215 E ALCAZAR ST	90033	14	135A225    11	5202001004	[T][Q]C2-1, [T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM			PC Approved	04/10/2017 12:00:00 AM	ADDRESS	34.06357	-118.20153	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA  4 AND 5. CHANGES CLOUDED ON PLANS. REDUCE RATING OF WATER HEATER AND UPDATED FLOOR PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51874	12041-10000-10760	1985 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM			PC Approved	05/10/2012 12:00:00 AM	ADDRESS	34.06159	-118.20463	Lab in USC, title 24 for 130 sqft , no emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51875	12041-20000-04392	6170 N WILBUR AVE	91335	3	177B121   336	2127014045	RA-1-K	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.18281	-118.54454	Replace 600A switchboard, transformer, and 400A subpanel.  All other subpanels and branch circuits, and feeder are existing and to be remained.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51876	19041-10001-30307	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	33.98076	-118.40716	PC FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES THE ADDITION OF FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51877	11041-10000-07465	926 S CROCKER ST	90021	9	124-5A211 165	5132002019	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/13/2011 12:00:00 AM	04/13/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.0355	-118.24971	CHANGE OF USE FROM WAREHOUSE TO  WHOLESALE ; THE BUILDING IS DIVIDED INTO 7 TENANT SPACES; PLAN CHK IS FOR CORE AND SHELL WITH FULL PLAN CHK OF TENANT SPACE # 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51878	19041-20000-29454	16000 W MULHOLLAND DR innovation-lab	90049	11	156B141     2	4490001***	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.13001	-118.48193	ti to an existing school.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51879	15041-20000-06020	1900 W 6TH ST	90057	1	133-5A205 334	5142001026	C2-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Expired	12/13/2017 12:00:00 AM	ADDRESS	34.05844	-118.27287	Title 24 plan check only.  Total area = 2,648 sq. ft.T.I. to existing restaraunt space including changes to envelope.  New emergency and general lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51880	16041-20000-06615	2888 W ROWENA AVE	90039	4	151-5A205 221	5434035027	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.10798	-118.26744	Plan check for power and energy. Project site is an existing commercial building. Project scope is power and lighting to a new additional building and a service upgrade. Total lighting area = 3,944 sq. ft.Note: Building permit has been issued under 15010-10000-02284	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51881	16041-20000-27025	9215 N CRANFORD AVE	91331	6	198B161   366	2629027904	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.23666	-118.41261	"New 2-story commercial building core and shell.  Plan check for power and energy.  service equipment only ""MSA"" all tenant panels and circuits to be future under seperate permit.  outdoor Title 24 only."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51882	19041-10000-43002	4641 N CARITINA DR	91356	3	168B117   474	2178015005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Issued	10/29/2019 12:00:00 AM	ADDRESS	34.15457	-118.55667	[E PLAN] 0$ FINAL FEES PER AB1414CHANGES TO AN APPROVED SET. CHANGES INCLUDE UPDATES TO CRITICIAL LOA D PANEL FROM 225A TO 200 A. (Revision to 19041-10000-35799)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51883	11041-10000-01902	10123 W RIVERSIDE DR Suite #-A	91602	4	165B181    38	2424008015	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM			PC Approved	01/31/2011 12:00:00 AM	ADDRESS	34.15238	-118.35147	REMODEL AN EXISTING 2,442 SQFT TO A COUNTER BURGER RESTAURANT , NO ALCOHOL BEVERAGES WILL BE SERVED , SOLD , OR CONSUMED ON OR AROUND PREMISES, MAX. 3-EMPLOYEE PER SHIFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51884	16041-20000-06610	13544 W PIERCE ST	91331	7	204B157   539	2646022007	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.25659	-118.4277	Plan check for a PV1 roof-mounted PV system. System size is 2 kWac and consists of (8) modules and (8) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51885	15041-20000-41925	13175 W MINDANAO WAY Unit A-2	90292	11	105B153   100	4212004006	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Info Complete	07/21/2016 12:00:00 AM	ADDRESS	33.98463	-118.43781	TI, PC for Energy only. Total area 1,430sq. ft. B# 15016-20000-27417  (CHG OF USE FROM RETAIL TO GYM)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51886	15041-20000-41799	329 S SYCAMORE AVE	90036	4	135B181   269	5507008006	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.06805	-118.34306	Plan check for a PV1 roof-mounted PV system. System size is 7.7 kWac and consists of (1) inverter and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51887	14041-20001-24827	7006 S HOOVER ST UNIT 1	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #1.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51888	15041-10000-13207	767 S ALAMEDA ST Building 2	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.03474	-118.24063	PLAN CHECK FOR MEDUIM VOLTAGE SWITCH GEAR. MAIN DISTRIBUTION SYSTEM IS UNDER APPLICATION #: 15041-10000-13198	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51889	13041-10001-00375	950-952 E 12TH ST	90021	9	123A211   200	5132013030	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.03131	-118.24832	Plan check for revision to approved plans. Delta 1. Replace the existing service to new 600A service and switchboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51890	14041-20000-31834	16916 W SHERMAN WAY	91406	6	183B133   167	2227026025	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Approved	12/22/2014 12:00:00 AM	ADDRESS	34.20094	-118.50182	"Convert the existing 38'5"" X 66'0"" restaurant/bar to retail, and restripe parking lot.  ""Comply with Department order effective date 9/8/2014.  Permit will expire 30 days from issuance date"".PC FOR T24 ENERGY ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51891	13041-10000-00197	111 E 1ST ST	90012	9	130-5A213  17	5161014902	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM	01/03/2013 12:00:00 AM		Permit Closed	01/25/2013 12:00:00 AM	ADDRESS	34.05206	-118.24284	Adding monitoring system panel to existing fire alarm system. 2 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51892	18041-10000-36581	8750 S VERMONT AVE	90044	8	096A199   110	6038010904	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			09/25/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	33.95806	-118.29132	NEW FIRE ALARM SYSTEM IN A NEW APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51893	13041-20000-21958	16869 W ENCINO HILLS DR PV-1	91436	5	162B133   234	2287002012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Expired	09/08/2015 12:00:00 AM	ADDRESS	34.13855	-118.50153	PV-1. Plan check for microinverter standard plan. 7.77kW Total	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51894	15041-20000-30793	7409 N WESTCLIFF DR	91304	12	186B089   324	2027044008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	PIN	34.20679065	-118.65240976	PV1 ROOF MOUNTED SYSTEM, TYING INTO AN EXISTING SYSTEM, INTERCONNECT WITH 225A MSP. (17) MODULES AND (1) UNGROUNDED INVERTER. TOTAL SIZE 3.8KW.(17) KYOCERA #KU2656ZPA(1)SE3800A-US-ZB-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51895	19041-10000-01833	810 E 3RD ST	90013	14	129A215   311	5163015016	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.04566	-118.23576	Energy plan check for a restaurant T.I . Scope includes new lighting and equipment with a total area of 1,194 SQ FT.Bld: 19016 10000 00669	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51896	15041-10001-14903	14518 W VENTURA BLVD	91403	4	166-5A151 139	2276001004	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.15087	-118.4494	((7/2/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2.  CHANGES INCLUDE ADDITION OF LIGHT FIXTURES AND REVISIONS TO ENERGY CALCULATIONS. MASTER PERMIT HAS NOT BEEN PULLED 15041-10000-14903, DO NOT ISSUE THIS SUPPLEMENTAL PERMIT UNTIL MASTER IS PULLED. Engery plan check for a retail to restaurant building (Presseat). Scope includes new lighting, equipment and receptacle outlet.**RELOCATE METER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51897	16041-20000-40732	5342 N SHOSHONE AVE	91316	5	171B129    33	2257003002	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.16828	-118.51615	pv1install rof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51898	13041-10000-05857	1120 S LOS ANGELES ST	90015	9	126A209   285	5145021002	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.03776	-118.25741	RENOVATION OF 3 TENANT SPACES TO ONE. USES INCLUDE OFFICE, WAREHOUSE AND RETAIL. PC FOR T24 ONLY. PERMIT TO BE ISSUED FROM PC STAFF ONLY. TOTAL AREA 6389 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51899	11041-10002-26376	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	33.98645	-118.44148	SUPPLEMENTAL: PERMITTED PLANS CHANGED IN THE FIELD (AS-BUILT); ADDITIONAL 7 BRANCH CIRCUITS; NO CHANGE IN LTGDELTA 4 CHANGES TO THE APPROVED PLANS. NEW CIRCUITS, LOADS & T-24.PLAN CHECK POWER AND ENERGY FOR RELOCATION OF 800A SWITCHBOARD, ESCALATORS, AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51900	11041-10000-10343	335 E 2ND ST 105	90012	9	129A215    54	5161017033	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.0487	-118.24051	TI TO AN EXISTING SALON.  T-24 OTC PLAN CHECK ONLY.  SUITE 105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51901	15041-20001-42620	300 S SANTA FE AVE WALKWAY	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	Change to approved set of plans. Changes include add 4 lighting fixtures and apply to delta 1 only. {{{{{{T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MIXED USED COMMERCIAL AREA (ONE SANTA FE YARDS ENCHANTMENTS). SCOPE INCLUDES NEW DECORATIVE LIGHTS. TOTAL HARDSCAPE AREA IS 22,162 SQ. FT.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51902	18041-10000-29139	1311 S WESTWOOD BLVD	90024	5	132B153   695	4324005017	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.05664	-118.44283	Plan check for T24 only, change of use from retail to retail with take out coffee ( no seating). Total area: 1,350 sq.ft. ((B# 18016-30000-23480))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51903	13041-20000-26368	5507 W HOLLYWOOD BLVD	90028	13	148-5A193 129	5544005024	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.10192	-118.30983	PC FOR POWER ONLY. NEW SERVICE UPGRADE. 2000A. NONHAZARDOUS. APPLICANT HAD PRE MADE CHECK. VERIFY FEES DURING PC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51904	18041-10001-42765	3061 S SAWTELLE BLVD	90066	11	120B157  1126	4250026036		West Los Angeles				2716.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.02552	-118.43114	PC ONLY TO DELTA 2 CHANGES TO REFLECT AS BUILT. cHANGES TO THE SINGLE LINE DIAGRAM WITH EXISTING 800A SERVICE. TOTAL CONNECTED LOAD IS LESS THAT 400A.  (((TITLE 24 PLAN CHECK WITH 2900 SQFT OUTDOOR AND INDOOR TO EXISITING SPACE SCOPE OF WORK INCLUDES NEW PANELS AND LIGHTING EQUIPMENTS. REGULAR PLAN CHECK PER CUSTOMER REQUEST.)))BL# 18016-10000-35738	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51905	19041-30000-09689	1423 S ABBOT KINNEY BLVD	90291	11	108B145  1348	4241036006	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	33.99059	-118.46514	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 906 sq. ft.Note: Building permit has been issued under 18016-30000-36113. Electrical permit fees have been paid under 19041-10000-07105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51906	11041-10000-13525	1000-1012 E LAKE ST Bldg 5-1	90291	11	111B145   574	4243003040	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.00142	-118.46071	New 2 story 11 unit apartment building.  Full plan check.Note to plan checker:  At the time application was generated plans were not provided.  Fees were generated based on what the engineer indicated in the plan check application form.  Verify fees and quantity of units during the plan check process.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51907	17041-20000-33860	1901 N ECHO PARK AVE	90026	13	142-5A211  34	5420022023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Apartment			09/21/2017 12:00:00 AM			PC Info Complete	12/21/2017 12:00:00 AM	ADDRESS	34.0864	-118.25188	Plan check for power and energy. New 13-unit (6 typ.), 3-story apartment over grade level parking. 800A 120/240 3ph 4w service. Total T24 area - 10,311sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51908	16041-10001-19569	1836 S ARAPAHOE ST	90006	1	126A201    82	5056011011	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM			PC Approved	08/14/2017 12:00:00 AM	ADDRESS	34.04075	-118.28511	PC FOR ELECTRICAL FIRE PUMP. PERMIT ALREADY ISSUED. THIS IS PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51909	14041-20000-16768	5314 N TOPANGA CANYON BLVD	91364	3	171B101   441	2169003045	C2-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.16641	-118.60555	New 400A service for a new hydrogen dispenser.  Install new equipment and panel.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51910	14041-20001-01478	23001 W BLYTHE ST	91304	12	189B097   589	2014027019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.21431	-118.62795	(((EXPEDITE FEEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. WITH POWER OPTMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51911	12041-10000-05926	355 S GRAND AVE 43, 44, 45-FLOORS	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK T24 ENERGY/EMERGENCY FOR REMODEL ON THE 43RD, 44TH, AND 45TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51912	14041-20000-08825	7100 N FAIR AVE	91605	2	183B173   136	2319022010	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.19988	-118.37482	Permit to be pulled at EPC counter only. Plan check for energy only as requested by inspector. Less than 400A. 1 story BLDG# 13016 40 22930: TI--FOR NEW OFFICE SPACE WITHIN (E) WAREHOUSE. changes on plan: added occupancy sensors to <250SF offices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51913	19041-20000-12853	5156 N WINDERMERE AVE	90041	14	163-5A221 246	5671017002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.14137	-118.21699	PV1.  Install 7.625 kW roof mounted grid tied PV system with 13.5 kWh energy storage system.  (25) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51914	16041-20000-00249	6119 ZELZAH AVE	91316	5	177B129   348	2123024021	RA-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Expired	02/02/2018 12:00:00 AM	PIN	34.18096724	-118.52360526	Plan check for PV roof mounted system. System size: 3.8kWac with 14 modules and 1 inverter(3.8kW). Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51915	14041-10000-25311	6290 W SUNSET BLVD STE B	90028	13	147A189   227	5546025029	(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.09777	-118.32646	"PLANCHECK FOR T24 ENERGY. INSTALLATION OF NEW PANEL FOR KITCHEN EQUIPMENT.  STE B""COMPLY WITH DEPARTMENT ORDER effective date07/17/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51916	12041-20000-02580	11041 N SEPULVEDA BLVD	91345	7	210B145   222	2664012048	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Approved	03/02/2012 12:00:00 AM	ADDRESS	34.27108	-118.46752	REMODEL AUTOMOBILE DEALERSHIP.ENERGY, EMERGENCY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51917	16041-20000-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	34.09822	-118.31812	Plan check for power and energy. Core and shell for new 16-floor Highrise Office Building with Ground Floor Retail. 1200A, 4160V service. T24 Area: indoor-463,185sqft; outdoor: 15,272sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51918	11041-10000-10022	8631 W 3RD ST #310	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.07373	-118.38036	Ti for a sandwich shop. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51919	16041-10001-07501	600 W WILSHIRE BLVD 5TH FLR	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			Corrections Issued	10/12/2016 12:00:00 AM	ADDRESS	34.04796	-118.25622	09/29/16Changes to an approved set of palns. All changes are clouded. Changes include removing unit equipment from lighting floor plan, providing two independent circuits for exit signs, and emergency lights are being fed from a geneator.  Changes per inspector's request.Note: Permit is paid under PCIS#16041-10000-07501((((((T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING COMMERCIAL BUILDING ON THE 5TH FLOOR (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 15,912 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51920	15041-10000-22239	900 E 4TH ST	90013	14	127-5A215 232	5163022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Closed	08/07/2018 12:00:00 AM	ADDRESS	34.04339	-118.23627	TI TO AN EXISITNG SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 8100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51921	16041-10000-24411	3924 S SYCAMORE AVE	90008	10	117B177   402	5029001031	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.01541	-118.35725	PC FOR ADDITION TO EXISTING SYSTEM. ADDITION OF 3KW INVERTER AND SOLAR LOAD CENTER. USING 8 MODULES AND POWR OPTIMIZERS	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51922	11041-10000-15916	111 N HOPE ST	90012	14	133-5A211 168	5161003910	PF-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			Corrections Issued	09/19/2011 12:00:00 AM	ADDRESS	34.05807	-118.24862	Relocate EV charchers and adding a new panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51923	16041-10001-38115	21425 W VANOWEN ST	91303	3	183B105   951	2138011023	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.19399	-118.59858	Supplemental PC for changes to approved set. Changes include removing grounding electrode, downsizing unit breakers from 125 to 100A , changing feeders from copper to aluminum and relocating electrical service equipment. Master permit 16041-10000-38115. All changes clouded under delta 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51924	18041-10000-38200	750 S LAMAR ST MAINTENANC-BLDG	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (D) THE MAINTENANCE BUILDING.4 OF 10BUILDING PERMIT # 13014-10000-04265	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51925	19041-20000-14380	1650 W FLORENCE AVE	90047	8	102B193  1413	6018003002	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	Apartment			04/19/2019 12:00:00 AM	06/09/2020 12:00:00 AM		Permit Finaled	02/01/2022 12:00:00 AM	ADDRESS	33.97435	-118.30648	Full plan check for a new apartment building 2000 amp service.  plan check for power and energy.Building application number 18010-10000-05189	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51926	13041-10001-12062	380 WORLD WAY #T53-R	90045	11			LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLAN CHK TO APPROVED SET OF PLANS-LIGHTING SYSTEM CHANGEDPLAN CHK ONLYPlan check power and energy. First-time tenant in retail space at Tom Bradley Int'l Terminal at LAX (Coach). Space #T53-R	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51927	16041-20000-08060	11110 W HARTSOOK ST	91601	2	171B173   788	2353007012	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			03/08/2016 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	34.16365	-118.37284	Plan check for power and energy. Project site is a new 5-story, 61-unit apartment building over 2 levels of sub-terranean parking garage. Total lighting area = 29,500 sq. ft.Note: Building application has been generated under 15010-20000-03668	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51928	12041-20000-15457	601 S FIGUEROA ST	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I. to existing high rise building on the 47th floor.  Install general/emergency lighting in rooms 4700, 47001 to 47007.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51929	17041-20000-11125	805 S MESA ST	90731	15	015B201   315	7455007021	R4-2-HPOZ	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	33.73671	-118.28586	permit fee $0.00 by state senate bill no.1222pv2install roof mounted pv system sized 34.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51930	14041-20000-31132	814 N SAN FERNANDO ROAD	90065	1	144A219    36	5453006048	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Info Complete	11/12/2014 12:00:00 AM	ADDRESS	34.09066	-118.22723	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW BRANCH CIRCUITS.  11,400 SQFT.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51931	11041-20000-27692	3401 N OAK GLEN DR	90068	4	159B177   500	2425021001	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2011 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.13086	-118.35321	New 7.13 KW roof mounted PV system for single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51932	17041-10000-17682	1925 S CENTURY PARK EAST SUITE 850	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.06066	-118.41426	PC for energy, Title -24 TI. on a high rise building, suite 850. New lighting and power. Load is less than 400 Amps. Area: 4,395 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51933	17041-20000-38709	1600 N CAMPUS ROAD 3RD FLOOR	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	Yes	1816.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.12626	-118.21412	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 4028 SQFT.3RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51934	16041-10000-37808	3838 S DUNN DR 1-86	90232	5	120B165  1263	4207004035	R5P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.02219	-118.39883	New Fire alarm system on a multi dwelling building. (5) panels,  (168) devices. Plan has been approved by the Fire Dept.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51935	14041-10000-31062	500 WORLD WAY Ter5 T5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	Firt time tenant for a retail (terminal 5, space 5T) at LAX airport.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51936	18041-20000-07809	20646 W CHESTNUT CIR (#334)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.29333	-118.58427	Plan check for a PV1 roof-mounted PV system. System size is 2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51937	16041-10000-44122	22445 W MICHALE ST	91304	12	192B101    67	2004017016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.2259	-118.61587	Plan check for PV roof mounted system. System size: 11.52kW with 36 modules LG LG320N1C(320W) and 36 microinverters Enphase S280-60-LL_2-US. Connect to 225 A panel with 200A Main Breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51938	11041-20000-23073	12614 W HESBY ST	91607	5	171B161   958	2357008038	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2011 12:00:00 AM	11/15/2011 12:00:00 AM		Permit Finaled	12/08/2011 12:00:00 AM	ADDRESS	34.16205	-118.408	New 10.5 KW DC roof mounted PV system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51939	18041-20001-07137	12106 N BELLANDO CT	91344	12	219B125    88	2601073017	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM			PC Approved	03/03/2018 12:00:00 AM	ADDRESS	34.29366	-118.52559	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 18.9KVA (11.4KVA NEW INVERTER (SE-11400-US), 7.5KVA EXISTING INVERTER) - NEW SYSTEM 35 PANELS WITH P400 OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51940	13041-10000-18143	11750 S JEFFERSON BLVD	90230	11	105B165   218	4220015033	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	PIN	33.98626775	-118.40053173	Demoliton of a Denny's restaurant and construction of a new Chick-Fil-A restaurant.  New 1000A service and distribution system.  Power and energy.  FA variance is submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51941	14041-20000-26294	10606 N COLLETT AVE	91344	12	207B141   539	2668007004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.26312	-118.48349	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(23) TRINA TSM-250 MODULES(1) ABB PVI-5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51942	17041-10001-31630	2100 W 3RD ST Suite 200	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.06281	-118.2731	PC for changes to approved set. Changes include change in lighting  layout and receptacles due to addition of health educational room. All changes clouded under delta 12.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51943	19041-10000-36781	21716 W COHASSET ST	91303	3	186B105   374	2111009001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.20632	-118.60208	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 5KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 16 MODULES(LG 330N1C-A5) USING P370 OPTIMIZERS CONNECTED TO EXISTING 200A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51944	18041-20000-43762	1128 S HUDSON AVE	90019	10	132B185   955	5083009019	R2-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.05408	-118.336	pv1install roof mounted pv system sized 6.4KW AC interconnected with msp.(20) panasonic 330W modules(20) enphase IQ7X micro inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51945	16041-10000-43968	445 S TOWNE AVE	90013	14	127-5A213 314	5147009001	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	34.04334	-118.2419	TI TO KITCHEN, OFFICE AND CHAPEL ON 1ST AND 2ND FLOOR. NEW LIGHTING UPGRADES AND POWER UPGRADES. THIS IS PLAN CHECK FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51946	17041-10000-38802	6171 N SEPULVEDA BLVD A-3	91411	6	177B145   355	2242001015	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			Reviewed by Supervisor	12/05/2017 12:00:00 AM	ADDRESS	34.18246	-118.46651	FULL PLAN CHECK TO A FIRST TIME TENANT. SCOPE OF WORK INCLUDES NEW RESTAURANT, AHIPOKI BOWL, RECEPTACLES AND LIGHTING. TOTAL SQ. FT. 1900.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51947	15041-10001-22890	3124 W SWAN PL	90026	1	154-5A219 211	5472010012	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/27/2015 12:00:00 AM	ADDRESS	34.09204	-118.27022	EXPEDITED FEES FOR ROOF MOUNTED SYSTEM. (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.4KW INTERCONNECTED WITH MSP.  (44) KYOCERA 2656ZPA MODULES(2) ABB PVI-4200 INVERTERS ((  SUBMITTAL PER APPLICANT))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51948	08041-10002-07922	18434 W VINCENNES ST	91325	12	198B125   170	2764011004	(T)(Q)R3-1L	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Apartment			11/16/2010 12:00:00 AM			PC Approved	12/09/2010 12:00:00 AM	ADDRESS	34.24083	-118.53505	25 units apartment building (8 typical). Electrical plan check for power and energy,  Original plans were lost.  The permit is existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51949	18041-20000-34926	520 N LA BREA AVE	90036	5	141B181  1058	5525020007	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.08092	-118.34385	New fire alarm system for (E) commercial building.  FACP with (13) notification and signaling line devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51950	18041-20000-22149	10250 W CONSTELLATION BLVD Suite 2710	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 Energy only in existing space office T.I.. Total area; 1246 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51951	11041-10003-17761	9247 N VAN NUYS BLVD 1-56	91402	6	198B149   342	2651009003	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Apartment			05/09/2013 12:00:00 AM			PC Approved	05/09/2013 12:00:00 AM	ADDRESS	34.23862	-118.45064	MODIFICATIONS TO APPROVED SET UNDER APPLICATION NUMBER 11041-10002-17761. DELTA- B CHANGES TO SHEETS E0.3CHANGeD FROM Al MC CABLES TO Al SE(R) cables**************************************************************************11041-10001-17761 DESCRIPTION: REVISIONS TO APPROVED SET OF PLANS- FEEDERS ON THE HOUSE DISTRIBUTION BOARD ARE CHANGRD FROM AL MC CABLES TO AL BUILDING WIRES; ALARM/STROBE AND HARD WIRED SMOKE ALARMS WITH 9V BATTERY BACK INSTALLED IN THE TWO SEEING AND HAIRING IMPAIRED UNITS.)))))))BRAND NEW 56 UNIT APARTMENT BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  FIRE ALARM WILL BE ON A SEPERATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51952	12041-10000-16869	1555 N GORDON ST	90028	13	148-5A191 299	5545007019	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			07/19/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	07/17/2013 12:00:00 AM	ADDRESS	34.09966	-118.31978	New Fire Alarm system for a new apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51953	16041-10000-10847	9622 S ANZAC AVE	90002	15	093A215   327	6046015041	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	33.9485	-118.23731	PV1, INSTALL 6 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (24) MODULES: CANADIAN SOLAR CS6P-260P(24) MICRO INVETERS: ENPHASE M250-60-2LL-S22-240standard plan is used.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51954	12041-10000-27523	315 W 9TH ST 1001	90014	9	127-5A209 141	5144018049	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	PIN	34.04341508	-118.25728547	PC FOR ENERGY. TI TO EXISTING COMMERCIAL OFFICE HIRISE. SUITE #1001	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51955	17041-10000-20782	941 N HIGHLAND AVE	90038	4	144B185  1015	5532012041	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.08829	-118.33879	PC FOR TI IN (E) MEDIA RELATED PRODUCTION SERVICES AND DEVELOPMENT FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES WITH NEW CIRCUITS.TOTAL AFFECTED AREA 8300 SQ.FT.BL# 17016-10000-08694	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51956	18041-10000-04057	5031 N ALONZO AVE	91316	5	171B129   362	2182007002	RA-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	10/06/2020 12:00:00 AM	ADDRESS	34.16167	-118.52046	PC for power and energy for new locker room building. Installing new 700A panelboard and 250kVA transformer lights, receptacles and equipment. Totala area is 47153sqft. B#18010-10000-00399	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51957	11041-20000-00255	13131 W SHERMAN WAY Bld. B	91605	2	183B157    37	2327003053	CM-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.20136	-118.41904	New auto service center Building B (West Building).   Core and Shell electrical plan check for power only.Note: Building A (East Building) is under 11041-20000-00253.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51958	11041-10001-27300	200 E WORLD WAY Terminal-#2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/28/2012 12:00:00 AM	PIN	33.94678571	-118.40391619	changes made to previously approved set, , conductors for the speaker circuits  changed from 14 to 16 awg.)))))))))))))))))))))))))))))))))))))))INSTALL A NEW FIRE ALARM SYSTEM IN TERMINAL #2 OF LAX. (((((((((((((((((((((((((((	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51959	14041-20000-05729	11478 W MOORPARK ST	91604	2	165B169   292	2365017003	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Apartment			03/03/2014 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	PIN	34.15006194	-118.38171208	NEW 8 UNIT APARTMENT BUILDING. FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51960	14041-10000-12535	2030 N KENILWORTH AVE	90039	4	147A205   328	5431018016	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.09625	-118.26809	PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER WITH OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51961	13041-20001-32791	5612 N VAN NUYS BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.17256	-118.44837	FIRST TIME TENANT REQUIRES FULL PLAN REVIEW. ENERGY HAS BEEN CHECKED AND APPROVED ON APPLICATION#: 13041-20000-32791. PERMIT HAS ALREADY BEEN PULLED, THIS IS A PLAN CHECK ONLY. PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51962	14041-10000-23608	2634 N ASTRAL DR	90046	4	153B177   169	5571022012	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.11767	-118.35744	pv1, install 17875 kw dc roof-mounted  solar array on a house, interconnect with main service panel, micro inverter(65) modules: sunmodule  plus sw 275 mono(65) microinverters: enphase m250Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0((((9/9/14))))Submittal 2:Standby emergency generator 48kW and backup battery system. Both with automatic transfer switches.No fee due to Senate bill 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51963	18041-10000-33950	14612 W SATICOY ST	91405	6	186B149   220	2218003033	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.20831	-118.45162	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51964	10041-10001-13704	1678 N ALTA MURA DR	90272	11	135B133   197	4425002020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2011 12:00:00 AM			PC Approved	04/26/2011 12:00:00 AM	PIN	34.06291525	-118.50074373	REVIEW OF THE CORRECTIONS AND CHANGES  TO CORRECTED SET OF PLANSPERMIT TO BE OBTAINED ON 10041-20000-13704Plan check for new single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51965	16041-10000-27962	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	33.95667	-118.4165	plan check T-24 only. in existing space TI. Private Schooltotal area 13840sq ft .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51966	18041-10000-26166	836 S STANFORD AVE	90021	14	124-5A213 300	5146023038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.03552	-118.24729	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51967	18041-20002-03145	19118 W MARILLA ST	91324	12	201B121   408	2762006012	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Issued	05/24/2018 12:00:00 AM	ADDRESS	34.24716	-118.55032	05/24/2018 Changes to an approved set of plans. All changes have been clouded. Tesla PowerWalls have been regrouped and there has been the addition of (1) load center.05/10/2018 Plan check for the addition of (2) Tesla PowerWalls onto an existing PV system. There are now a total of (3) PowerWalls.*****Previous Work Description*****Plan check of the addition of (1) Tesla PowerWall to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51968	14041-20001-29059	3541 N WESTFALL DR	91436	5	159B137    92	2293008005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.13539	-118.49314	EXPEDITE PER APPLICANT REQUEST[PV1Install roof-mounted solar array, interconnect with MSP. 2 inverters, system size 9.2kW. 50 255W pv modules across a total of 4 strings. 400A main service.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51969	19041-30000-46857	590 N VERMONT AVE	90004	13	141B197   978	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.08157	-118.2915	ENERGY PLAN CHECK ONLY, AREA OF SCOPE 2496SFBUILDING PERMIT # 19016-30000-36819	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51970	18041-10000-09311	100 WORLD WAY #T164	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	Plan check for Title 24 only in existing space T.I. LAX retail concession T1. Total area: 781 sq ft.B#18016-10000-07683	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51971	10041-20000-25795	17330 W CUMPSTON ST	91316	5	174B133   813	2257011054	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2010 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	34.16943	-118.51115	PHOTOVOLTAIC SYSTEM 16.9 KW AND 400 AMP SERVICE UPGRADE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51972	18041-20000-24234	960 N NORTH MAIN ST	90012	1	135A217   168	5409009005	UC(CA)	Central	Central City North			2060.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	05/14/2020 12:00:00 AM		Permit Finaled	12/20/2021 12:00:00 AM	ADDRESS	34.06236	-118.23416	Plan check for Title 24 only. Project site is a new 3-story self-storage building with 1 level of basement. Total lighting area = 63,736 sq. ft.Note: Building application has been generated under 17010-10000-04089	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51973	12041-10001-01164	9413 S SPRING ST	90003	8	093A203    60	6053006922	RD1.5-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Apartment			02/25/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	33.95054	-118.2769	CHANGES TO PERMITTED SET OF PLANS: UPGRADE SERVICE TO 1600A ; AL FEEDERS ON HOUSE SWBD DECREASED BUT THE LOADS ON THE PANELBBOARDS REMAINED AS-IS; LUMINAIRE P WENT FROM LED TO FLUORESCENT;REARRANGE LINE-UP IN ELECTRICAL ROOM;LUMINAIRE P1 BECAME PENEW 3-STORY, 49 UNITS APARTMENT BUILDING, TYPE VA,  98% AFFORDABLE HOUSING DEVELOPMENT.   W/48 SENIOR AFFORDABLE  UNITS, AND ONE MANGERS UNIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51974	17041-10000-40410	3064 N DEEP CANYON DR	90210	5	159B157   190	4385001022	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.13019	-118.43122	PC for rooftop solar PV system for 10kW AC system . Installing 37 modules with optimizers and central inverter. DC size is 13.14kW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51975	17041-10000-42935	651 WORLD WAY	90045	11	090B165   118	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.94326	-118.4019	Power plan check for temp' power supplying the trailers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51976	19041-10000-11937	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCLUDES THE EXTENSION OF AN EXISTING TENANT SPACE. NEW LIGHTING AND CIRCUITS. TOTAL SQ. FT. 820.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51977	19041-20000-34534	10006 N MELVIN AVE	91324	12	204B117   551	2726011022	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.25211	-118.56081	PV1.  Install 14.03 kW roof mounted grid tied PV system.  (46) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51978	10041-10000-05735	313 S 4TH AVE BLD E	90291	11	111B141   532	4286006034	[T][Q]CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	12/06/2010 12:00:00 AM	ADDRESS	33.99722	-118.47499	CHANGE OF USE PART OF  AN (E) CARETAKER AND (E) STOREGE SPACES TO RETAIL AND OFFICE SPACES.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51979	10041-20000-16597	3601 S TROUSDALE PKWY #202-#300	90089	8	118-5A201   1	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	09/28/2010 12:00:00 AM	ADDRESS	34.02017	-118.28558	Plan check T-24 Energy general/emergency lighting for USC Student Union #202 and #300. Permit for work on existing lighting ckts, additional ckts, and low voltage micro relay panels and devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51980	10041-10000-03767	403 W AVENUE 33	90031	1	142-5A221 168	5205003008	MR1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	34.08398	-118.21683	New LAPD auto/truck repair building.  Electrical plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51981	16041-30000-12217	21001 W SHERMAN WAY	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.20126	-118.59094	Plan check for power only.  Health care facility with exam and procedure rooms (planned parenthood).  Installation of new 15 kVA UPS and associated 60 A panel with receptacle loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51982	16041-10000-44484	1610 W CARSON ST	90501	15	051B193   930	7346003012	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Apartment			12/21/2016 12:00:00 AM			Reviewed by Supervisor	02/01/2017 12:00:00 AM	ADDRESS	33.83132	-118.3069	FULL PC FOR POWER AND ENERGY FOR A NEW 3-STORY 16 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW 800A 120/240V 1PHASE 3WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS(USING ONE TYPICAL PANEL FOR ALL UNIT TYPES). B#16010-10000-05889	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51983	13041-10000-34442	2607 E DARWIN AVE	90031	1	136-5A221 262	5210003037	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Expired	04/05/2016 12:00:00 AM	ADDRESS	34.06767	-118.21518	PV1, Install a 2.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (9) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. Ungrounded system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51984	12041-10000-04851	1246 E OLYMPIC BLVD	90021	9	123A213    53	5132006010	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	03/02/2012 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	34.03248	-118.24493	T. I. - COMMERCIAL SPACE. P/check for compliance with lighting requirements of T-24 including emergency egress lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51985	10041-20000-18330	6222 N SEPULVEDA BLVD	91411	6	177B145   292	2242010026	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/20/2010 12:00:00 AM		Permit Finaled	11/01/2010 12:00:00 AM	ADDRESS	34.1836	-118.4659	T.I. to existing building in office space.  EPC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51986	13041-10002-35017	21800 W VICTORY BLVD	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM			PC Approved	07/23/2015 12:00:00 AM	ADDRESS	34.18712	-118.60325	UPDATE PLANS TO REFLECT FIELD CHANGES TO THE PLANSSEE ATTACHED SHEET OUTLINING PAGES AND CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51987	17041-10000-08057	711 W FLORENCE AVE	90044	8	102B201   861	6013023046	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	07/24/2019 12:00:00 AM		Issued	07/24/2019 12:00:00 AM	ADDRESS	33.9748	-118.28617	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTING CLINIC. SCOPE INCLUDES A NEW 600A 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARDS, NEW PANELS, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 4667 SQ. FT.  B#17014-10000-01066	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51988	12041-20000-26577	6250 W HOLLYWOOD BLVD # 100	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.10133	-118.32547	CHANGE OF USE FROM RETAIL TO RESTAURANT WITH OUTDOOR SEATING. - T.I.   NEW PARTITIONS, NEW ADA RESTROOMS.  Plan check for T24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51989	19041-10000-14317	11919 W OXNARD ST	91606	2	177B165   516	2334011022	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.17955	-118.39265	REMOVE INDOOR / OUTDOOR FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS. (1ST AND 2ND FLOOR) AND METAL HALIDE FIXTURES TO LED	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
51990	13041-20000-22524	111 E UNIVERSAL HOLLYWOOD DR SUITE 2150	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	RENOVATION OF EXISTING OFFICES. NEW LIGHITNG. PC FOR T24 ENERGY ONLY. TOTAL AREA 5882 SQ FT. WORK DONE IN SUITE 2150	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51991	16041-20001-00515	17532 W SUPERIOR ST	91325	12	201B129   281	2755009020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	34.2466	-118.51692	EXPEDITE PER APPLICANT REQUEST[Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 10.2kW (4.2+6). Ungrounded system. (46) 265W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51992	15041-10000-26810	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	PC FOR ENERGY. PART 2 OF THE WEST FIELD CENTURY CITY PROJECT. TOTAL AREA = 1432 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51993	16041-20001-23271	8892 W COLLINGWOOD DR	90069	4	147B169   849	5560038003	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.09603	-118.385	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (3) inverters, (61) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51994	15041-10000-03195	639 N BROADWAY Unit G	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	PIN	34.05985996	-118.23998637	Energy plan check for a restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
51995	14041-20000-31046	5753 N BERTRAND AVE	91316	5	174B125   184	2159015029	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.17523	-118.52551	Roof mounted PV system with microinverter, model M215-60.  Total system size 3KW.Note: The solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
51996	14041-10001-09288	2630 S ALMA ST	90731	15	009B197   863	7463017005	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	33.72005	-118.29889	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3000A-US-ZB-U. (10) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51997	15041-20001-00794	3244 S SHELBY DR	90034	5	123B165   695	4311004033	R1-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/30/2015 12:00:00 AM	ADDRESS	34.03285	-118.40099	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.(28) SUNPOWER SPR-E20 MODULES(1) FRONIUS 10.0-1-UNI INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
51998	16041-10000-29528	821 S MATEO ST	90021	14	123A217    49	5166017013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.03285	-118.23244	New PV solar system on existing commercial building.  38 new PV modules, two new 6 KW inverters, new subpanel feeding existing loads, and new load center to combine AC inverter outputs.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
51999	16041-20000-16017	15831 W MOORPARK ST	91436	5	168B141   504	2261012012	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.15691	-118.47819	PV1INSTALL ROOF MOUNTED PV SYSTEM STANDARD PLAN.  SYSTEM SIZE 7.6KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52000	16041-20002-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	04/17/2018 12:00:00 AM	ADDRESS	34.09822	-118.31812	Revisions to approved set of plans.  Reduction of (2) floors from original approved set.  Revised medium voltage gear locations.  Revised fire pump location.  SLD changes throughout.  Floor plan layout changes.  (((Plan check for power and energy. Core and shell for new 16-floor Highrise Office Building with Ground Floor Retail. 1200A, 4160V service. T24 Area: indoor-463,185sqft; outdoor: 15,272sqft.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52001	17041-10000-37190	7857 N SEPULVEDA BLVD	91405	6	189B145   472	2222002013	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.21355	-118.4664	INDOOR AND OUTDOOR REPLACEMENT OF HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52002	15041-20000-43174	221 N FIGUEROA ST 14th flr	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.05882	-118.25099	Tenant improvements on  14th floor. PC for energy only, total area: 14,224 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52003	10041-10000-25286	4666 W SANTA MONICA BLVD	90029	13	144B197   761	5539003024	C2-1D	Central	Hollywood	East Hollywood	YES	1914.10	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	07/09/2012 12:00:00 AM	ADDRESS	34.09066	-118.29149	New convenience store for a gas station. EPC is for power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52004	19041-10000-03698	12391 N MONTERO AVE	91342	7	219B161   273	2525028018	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.29485	-118.4098	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52005	19041-10000-51345	937 E 25TH ST	90011	9	118-5A209  36	5131021007	R3-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Apartment			12/12/2019 12:00:00 AM	08/24/2021 12:00:00 AM		Permit Finaled	05/17/2023 12:00:00 AM	ADDRESS	34.0203	-118.25559	NEW APARTMENT BULDING. INSTALLING NEW 600 AMP SERVICE, PANELS & CIRCUITS.((((N) 3-STORY 17-UNIT 100% AFFORDABLE HOUSING APARTMENT BUILDING W/ MANAGER'S OFFICE. NO VEHICLE PARKING. BULDING PERMIT: 18010-10000-04286))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52006	15041-10000-04351	1111 S FIGUEROA ST	90015	9	127-5A207 149	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.04338	-118.26581	Plan check for fuel cell. Installation of Natureal gas powered Full Cell.Note: Address to be determined prior pulling permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52007	16041-10005-01886	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Application wanted to stamp an extra set of approved plans for 16041-10003-01886. This aplication covers 1 pc hour to verify that plans where the same on new set.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52008	19041-20000-00958	9661 W WENTWORTH ST	91040	7	207B181    32	2549004012	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.26427	-118.34278	Plan check for PV roof mounted system, sytem size: 18.58 KW DC, 15.5KW ACwith 58 PV Modules and 2 inverters(7.6kW)  connected to 400A Service.Permit fees $11.48 due to california senate bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52009	14041-20003-02681	14329 W CARL ST	91331	6	201B153   520	2644024011	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.24716	-118.44537	MODIFICATIONS TO APPROVED SET.  REDUCTION OF # OF JUNCTION BOXES FROM 2 TO 1.    $0 PC FEE DUE TO SENATE BILL 1222 FROM 2012(((CHANGE IN SET OF APPROVED PLANS. CHANGE IN OCPD RATING TO 30A. ADDITION OF SOLAR MONITORING BOX.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52010	17041-10000-19336	2750 W COLORADO BLVD suite 3	90041	14	163-5A219 154	5682002025	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.14257	-118.22587	PC for T24 only for TI for message rooms.PC for new lights. Total of 779 sqft. Building # 17016-10000-07031.CEIS 754009COMPLY WITH DEPARTMENT ORDER effective date02/24/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52011	10041-10000-01594	12035 E WATERFRONT DR	90094	11	105B161  1201	4211011029	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM	03/11/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	PIN	33.98250733	-118.40585209	FIRST TIME TENANT COFFEE  SHOP. NEW PANEL , XFORMR,AND TITLE 24. POWER, LIGHTING AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52012	19041-10000-49870	966 S DEWEY AVE	90006	10	129B197    45	5078006019	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.20	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM			Reviewed by Supervisor	12/11/2019 12:00:00 AM	ADDRESS	34.05364	-118.29567	NEW 2,000 AMP SERVICE, 42 PANELS, 806 CIRCUITS & 51,933 SFT ENERGY.((((Bldg Permit: 19010-10000-04075 --- NEW 99 GUESTROOMS HOTEL (6-STORY) 1 SUBTERRANEAN PARKING GARAGE, GROND LEVEL PARKING GARAGE, 6-STORY HOTEL TYPE III-A BASEMENT & GROUND PARKING TYPE I-A PER ZA-2017-3446-VCU-CUB-ZAA-SPR.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52013	17041-20001-45990	3876 W FRANKLIN AVE	90027	4	150B201  1404	5433012004	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM			PC Approved	01/01/2018 12:00:00 AM	ADDRESS	34.10363	-118.27665	EXPEDITED PER APPLICANTS REQUEST. INSTALLATION OF ENERGY STORAGE SYSTEM 13.5 KWH.  PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM 7.5 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52014	14041-20001-05155	12698 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/25/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	33.97714	-118.41552	)((EXPEDITE FEES)))PC FOR SERIES OF PHOTOVOLTAIC SYSTEMS FOR NEW CONDOS. THIS SYSTEM IS SPECIFIC FOR UNIT 3. SYSTEM SIZE 3KW AC. SYSTEM IS TIED TO MAIN SERVICE SERVING OTHER UNITS. THIS IS PLAN CHECK AND PERMIT SUBMITTAL 3 OF 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52015	12041-20000-11682	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin # 178 T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52016	17041-20001-45634	3774 W EFFINGHAM PL	90027	4	154-5A203 246	5592004029	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.11689	-118.27576	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.10.56kW ungrounded system. (33) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52017	19041-10000-47353	11582 W RIVERSIDE DR	91602	2	168B169  1090	2354016066	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.15741	-118.38496	NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 4.02KW DC/ 3.8KW AC, WITH A CENTRAL INVERTER (SE3800H-US), 12 MODULES (LG335N1C-A5), AND 12 POWER OPTIMIZERS (P370).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52018	14041-20000-06394	5408 E HUNTINGTON DR SOUTH	90032	14	145-5A237 271	5219033023	RD1.5-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.09122	-118.1633	Roof mounted PV system with 2.99KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52019	10041-20000-02485	6728 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	04/07/2010 12:00:00 AM	ADDRESS	34.11816	-118.33995	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52020	16041-20001-36730	4215 S GLENCOE AVE	90292	11	108B153  1423	4230032***	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			04/18/2019 12:00:00 AM			PC Approved	04/18/2019 12:00:00 AM	ADDRESS	33.98812	-118.44136	"SUPLEMENTAL CHANGE TO APPROVED SET, PLAN CHECK ONLY, CHANGE IN DISCONNECT SWITCH FUSE SIZE FROM 800 TO 600 FOR MSD AND 600 TO 500 FOR MSE, CHANGE IN CONDUCTOR SIZE FROM #500 TO #350 FOR MSD FEEDER, CHANGE IN FEEDER LENGTH TO 20 FEET.*original*Plan check for power only. Project site is an existing apartment complex. Project scope is the addition of distribution equipment ""MSD"" and ""MSE"" for future EV chargers."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52021	14041-20000-35749	4824 N SUNNYSLOPE AVE Bld. 4D	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.15859	-118.42562	New 3 story apartment with 26 units and 3 level subterranean garage.  New 2000A service, panels, branch circuits, and lighting.    Plan check for power and energy.Note: variance to separate fire alarm plans submitted on 12/29/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52022	15041-20000-07483	14141 W VENTURA BLVD	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM			Reviewed by Supervisor	03/24/2015 12:00:00 AM	ADDRESS	34.14992	-118.44152	Power plan check only.  Installation of new 400 A subpanel to provide power to first time tenant retail space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52023	17041-10000-18096	305 E 7TH ST	90014	14	127-5A211 232	5148023019	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.0424	-118.24888	Title 24 plan check.  Remove HID fixtures and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52024	14041-20000-23237	8846 N HATILLO AVE	91324	12	195B113    80	2782034003	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.23164	-118.56545	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS IVNERTER, USING STANDARD PLAN. SYSTEM USES 23 MODULES. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52025	12041-10000-26679	10801-10807 N SAN FERNANDO ROAD Bldg A	91331	7	207B157   309	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Info Complete	11/26/2012 12:00:00 AM	ADDRESS	34.26635	-118.42259	"Methane mitigation submittal - Building 'A' Restoration of building. Interior and Exterior remodel. (Buildings A through D were submitted together application numbers are: (A) 12041-10000-26679, (B) 12041-10000-26680, (C) 12041-10000-26681, (D) 12041-10000-26682). <<Per applicant's request, Mr. Jose Delgado, the status was changed to ""Plan Check Only"".>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52026	09041-20010-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to previously approved set of plans.  PLAN CHECK ONLY for ""DELTA 223"".         <<<T. I. - new medical office bldg.(NEW HIGH RISE BUILDING, MEDICAL OFFICE, SHELL UNDER PCIS 08041-20000-22411)>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52027	17041-10000-14845	1019 S CATALINA ST	90006	1	129B197   297	5078013005	C2-1, R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			05/04/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	04/12/2021 12:00:00 AM	ADDRESS	34.05214	-118.29493	PC FOR FA SYSTEM FOR NEW APARTMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52028	10041-20000-06315	13571 W VAUGHN ST	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM	04/07/2010 12:00:00 AM		Permit Finaled	05/17/2010 12:00:00 AM	ADDRESS	34.27758	-118.42846	REVISION TO APPROVED PLANS MOVE SOURCE OF FEEDER FROM 1200a TO EXISTING 1600A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52029	16041-20000-45659	4814 W OAKWOOD AVE	90004	4	138B193   312	5522033017	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.07702	-118.31194	Plan check for fire alarm only. New fire alarm system for 11-unit apartment building. 1 FACP, 44 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52030	13041-20000-36032	623 W ROMULO ST	90065	1	144A219   181	5453017023	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.08935	-118.22159	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52031	10041-20000-23811	816 S BROADWAY	90014	14	127-5A209 160	5144016064	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			PC Info Complete	11/30/2010 12:00:00 AM	ADDRESS	34.04321	-118.25497	Plan check T-24 Energy for general/emergency lighting. Permit under #10041-10000-20096	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52032	18041-20000-12919	3303 W WILSHIRE BLVD 3rd Floor	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.06195	-118.29439	Plan check for Title 24 only in existing high-rise building office T.I. New lighting and receptacles. Total new load less than 400A. Total area: 8,983 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52033	14041-10003-34558	5100 W WILSHIRE BLVD 1-138	90036	4	132B181    39	5507026001	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			06/04/2018 12:00:00 AM			PC Info Complete	06/21/2018 12:00:00 AM	ADDRESS	34.06187	-118.34094	** changes to approved plan noted as Delta-4. Scope includes circuit breaker change, series rating change, number of units change, apartment numbering change, load change on distribution board, elevation drawing change change.<<<08-31-2016 Changes to an approved set of plans. Changes include reduce quantity of washer and dryer, and add loundry circuts on MSA, MSB, MSC, and MSC, add new panel and circuits on Panel HPG4 & HPG5 and add new lighting fixtures relocate circuits on some of the panels. Changes apply to Delta 2 only. Title 24 based on 2008 Code. Power plan check for new 7 story 138 unit apartment building.  New 5000 A service.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52034	15041-20000-01899	13420 W VAN NUYS BLVD	91331	7	207B157   704	2620007028	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.26363	-118.42505	INTERIOR TENANT IMPROVEMENTS ON EXISTING THREE STORY OFFICE BUILDING. GROUND FLOOR AND 2ND FLOOR OFFICE SPACE ONLY.PC FOR T24 ENERGY ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52035	15041-20001-29259	10201 W PICO BLVD Galaxy grg	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	PIN	34.05182951	-118.41257696	Expedite per customer((PV2 Installation of (1) commercial carport canopy solar PV Power system,(2128) modules: sunpower SPR-E20-327-COM(19 inverters: CPS SCA 28KTL-DO/US1 out of 3 sites on the same address.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52036	17041-20000-09740	926 N SYCAMORE AVE	90038	4	144B181   717	5532010049	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			Reviewed by Supervisor	04/05/2017 12:00:00 AM	ADDRESS	34.08796	-118.34265	Proposed 4-story addition to existing 1 story manufacturing building.  Commercial core and shell.  3000 A 480Y/277V service.  Plan check for power and energy.  Building permit submitted under 16014-10000-03639	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52037	17041-10000-24583	10050 S JUNIPER ST 101-206	90002	15	091-5A217 111	6046019929	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/11/2020 12:00:00 AM	ADDRESS	33.94618	-118.23331	NEW 3 STORY, 10 UNIT APARTMENT BUILDING. 600 A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52038	12041-20000-12528	431 W 7TH ST	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM			PC Approved	05/31/2012 12:00:00 AM	ADDRESS	34.04654	-118.25516	T.I. to existing high rise building on 1st. floor.  Install general/emergency lighting in common corridor and restrooms.  Plan check for energy only.Note: Permit issued under 12041-20000-12060.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52039	19041-20000-06872	8700 S PERSHING DR PV4	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	07/11/2021 12:00:00 AM	ADDRESS	33.95471	-118.44097	PV2.  Install 25.55 kW DC / 23.34 kW AC roof mounted grid tied PV system.  (70) modules with (1) 20 kW rated string inverter.  Interconnecting with MSA-4.  $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52040	17041-10000-43336	10637 W OHIO AVE	90024	5	132B153   510	4326015031	R1-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.05759	-118.43343	PC FOR roof mounted pv ON SFD. System size is 8.12KWac 8.4KWdc SCOPE INCLUDES 28 modules (SolarWorld SWA 300) WITH MICRO INVERTERS AND NEW LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52041	14041-20000-27244	224 N TROTWOOD AVE	90732	15	018B189   183	7559009022	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	33.74501	-118.317	PV STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52042	19041-10001-42029	1500 S GRANVILLE AVE	90025	11	126B149   386	4262006032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	04/10/2020 12:00:00 AM	PIN	34.04297561	-118.45708387	Expedite per applicant's request.Plan check for a PV2 73.3KW AC/ 73.1kW DC roofmounted system. Scope includes (1) load center, (3) inverter, (186) modules, and (75) P860 optimizers and (36) P400 Optimizers interconnecting through the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52043	19041-10000-28542	20101 W RINALDI ST #100	91326	12	213B113   483	2701100006	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.27545	-118.57197	POWER AND ENERGY PLAN CHECK. TENANT IMPROVEMENT FOR RESTAURANT (FIRST TIME TENANT). SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 2122 SQ.FTB#19016-10000-22822	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52044	10041-20000-16999	1269 S WESTWOOD BLVD	90024	5	132B153   602	4324004015	C4-1VL-POD	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	05/11/2011 12:00:00 AM	ADDRESS	34.05732	-118.44321	PLAN CHECK POWER AND ENERGY CHANGE OF USE ON SECOND FLOOR FROM GENERAL OFFICE TO DENTAL OFFICE. NEW 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52045	11041-10000-27345	6600 N TOPANGA CANYON BLVD #2102	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	T. I.  for clothing store, load <400A, plan check for T-24 lighting compliance and emergency egress lighting.(T. I. - REMOVE INT. DEMISING WALL TO EXPAND 3 (E) UNITS INTO ONE SPACE (6,540 sq.ft.) INSIDE COVER MALL -  work includes interior t.i. and replacing (E) store front windows and doors.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52046	17041-30000-45004	5919 N RIVERTON AVE	91601	2	177B177   691	2415012023	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.17812	-118.36606	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52047	14041-10000-30167	12005 W VOSE ST	91605	2	183B165   117	2321003032	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.19855	-118.39457	Title 24 plan check only.  Total area = 2,592 sq. ft.Remove HID lighting and install LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52048	18041-20000-02660	9750 N ANDORA AVE	91311	12	201B097    78	2724009012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.24788	-118.6225	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 11.4KVA CONSISTING OF 1 CENTRAL INVERTER(SOLAREDGE SE11400A-US), AND 35 MODULES WITH P400 POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52049	12041-10000-28227	7159 W 91ST ST	90045	11	096B157   935	4119031009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	33.9555	-118.42005	PV1 roof mounted 2.1 kW AC / 2.45 kW DC system using the ENPHASE M215 micro inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52050	18041-20000-04909	501 N SOTO ST	90033	14	129A225   101	5175009029	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.04865	-118.20687	Plan check for a PV2 roof-mounted Pv system. System size is  11.4 kWac/15.0 kWdc and consists of (1) inverter and (50) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52051	15041-20000-31009	841 N KENTER AVE	90049	11	138B137   328	4426030007	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.07374	-118.49131	Plan check for PV roof mounted system. System size: 15.4kW with 56 modules and 2 inverters (7.7kW)Note: fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52052	10041-10001-05583	700 N FAIRFAX AVE	90046	5	141B177   515	5527011005	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	03/08/2011 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	34.0841	-118.36119	REVISION TO APPROVED PLANS. METHANE BUFFER ZONE.  EPC FOR POWER AND ENERGY OF ONE STORY RETAIL BUILDING I.  METHANE MITIGATION REPORT WAS PROVIDED. NEW SERVICE, PANELS, CKTS, & T24. ORIGINAL PLAN CHECK #08041-10000-07840(((((  CHANGE FUSES TO BREAKERS AND SERVICE FROM UNDER GROUND TO OVER HEAD NE CHANGES TO THE FAULT VALUE FULLY RATED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52053	16041-30000-36786	1349 S ABBOT KINNEY BLVD	90291	11	108B145  1282	4239027016	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	33.99083	-118.46621	Title 24 plan check.  New lighting in restrooms and around chairlift.  Permit is for new lighting.  Other items permited under 16041-30000-2022	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52054	19041-10000-12883	10731 W PICO BLVD	90064	5	126B157   734	4320004113	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.04152	-118.42593	PC T-24 only for BofA (change of use). Area scope 6,517SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52055	12041-10000-28184	23345 W SANDALWOOD ST	91307	3	186B093   530	2027007011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	01/02/2013 12:00:00 AM	ADDRESS	34.20369	-118.63692	PV1 5.616 KW ROOF-MOUNT ENPHASE MICROINVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52056	15041-20001-39576	21770 W LOS ALIMOS ST	91311	12	207B105   135	2722035009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.26598	-118.60334	EXPEDITE PER APPLICANT REQUEST. (((PV1, roof mounted solar panel, interconnected with 200MSP.  (42)modules: SW285   (42)microinverters: Enphase M250-60-2LL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52057	13041-10000-17758	3322 W SUNSET BLVD	90026	13	142-5A203  16	5426007018	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.08694	-118.27577	permit to be pulled at EPC counter. PC for energy only. TI existing restaurant . 1 story	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52058	14041-10000-10057	535-537 W 7TH ST	90731	15	015B197   551	7454003007	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	33.73774	-118.28879	PLAN CHECK FOR ENERGY ONLY FOR EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52059	16041-20000-06666	7712 N PASO ROBLES AVE	91406	6	189B133   920	2203012022	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Expired	03/28/2018 12:00:00 AM	ADDRESS	34.21079	-118.5022	Install a roof-mounted solar array on a SFD. Interconnect with a 100A MSP.System size: 3kW. Ungrounded system. (12) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52060	14041-20000-14905	7323 N ETHEL AVE	91605	2	186B161   557	2327003016	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Expired	04/17/2017 12:00:00 AM	ADDRESS	34.20377	-118.41827	Service upgrade to 600A.  New service panel, transformer, and panels.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52061	15041-10000-08111	330 S HOPE ST # 100	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.05319	-118.25252	ALTERATIONS  IN EXISTING RESTAURANT-NEW CIRCUITS PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52062	16041-10000-09077	450 S WESTERN AVE #216	90020	10	135B193   649	5503014020	R3-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	T-24, PC FOR ENERGY ONLY. TI FOR A NEW RETAIL STORE ON SECOND FLOOR WITHIN (E) SHELL COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND TWO NEW PANELS. TOTAL AFFECTED AREA IS 665 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52063	13041-10000-11236	12001 W CHALON ROAD	90049	11	141B141     5	4429003027	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/01/2013 12:00:00 AM	ADDRESS	34.08469	-118.4849	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING FOR 4700 SQUARE FEET OF A CONFERENCE ROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52064	15041-10000-23220	1631 E 42ND ST	90011	9	114A213   218	5116014020	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.00652	-118.24445	PV1, INSTALL 9.62 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY. (37) MODULES: KYOCERA KU2656ZPA(1) ABB PVI-5000-OUTD-US-Z-D AND ADD PVI-3.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52065	11041-10001-00227	2100 E PACIFIC COAST HWY	90744	15	033B213    10	7428007003	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Info Complete	12/10/2012 12:00:00 AM	ADDRESS	33.79122	-118.23692	REPLACE AN EXISTING FIRE PUMP SYSTEM IN THE SOUTH PLANT OF TESORO REFINARY.(((((((((((((((  12-10-12 deleting the interlock  tie between the main 400 amps brkrs..))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52066	18041-30000-43482	2029 S CENTURY PARK EAST 13TH FLOOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT RENOVATION OF PUBLIC RESTROOMS. NEW LIGHTS WILL CONNECT TO EXISTING BRANCH CIRCUIT SERVING THE AREA. TOTAL AREA: 410 SQ.FT(B# 18016-10000-25387)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52067	15041-10002-26870	864 S VERMONT AVE	90005	10	132B197   748	5077024038	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM			PC Approved	08/12/2019 12:00:00 AM	ADDRESS	34.0563	-118.29145	CHANGES TO PERMITTED SET OF PLANS TO REPRESENT AS-BUILT CONDITIONS. CHANGES ARE MARKED AND CLOUDES AS DELTA 4 CHANGES. CHANGES INCLUDE DISCONNECT FOR FIRE PUMPS, ADDITION OF SUMP PUMPS, OUTDOOR LIGHTING ARE NOW WALL-MOUNTED, CHANGES TO 2ND AND 5TH FLOORS LIGHTING SYSTEMS. ISC VALUES SHOWN ON THE PLANS. eLEVATORS ARE NOW TRACTION TYPE-LESS LOADING PLAN CHECK ONLY((((((((NEW 5-STORY COMMERCIAL BLDG WITH RETAIL AND ABO.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52068	17041-10000-18837	5901 N CANOGA AVE	91367	3	177B105   103	2146006019	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.17755	-118.59772	Title 24 plan check.  T.I. to existing bank office.  One new 225 amp panel with new lighting, receptacles, and HVAC.  Total area = 6,104 sq. ft.Building permit #17016-10000-14677	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52069	17041-20000-08171	4300 N ARCOLA AVE	91602	4	165B177   697	2424023008	RE11-1-H-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.14805	-118.35489	PV1.  Install roof mounted PV system sized 23kw interconnected with MSP. This design is changes to an approved set with changes exceeding 50% of total design.  Partial permit fees were paid under application number 15041-10000-22844.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52070	17041-20002-45363	19821 W FALCON CREST CT	91326	12	217-5A115 155	2701018026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.29071	-118.56524	07-16-2018 Changes to an approved set of plan. Changes include increase PV roof mounted system. inverter size to 11.4kW Solaredge Single Phase Inverter. all Changes has been clouded. Plan check only Fees $0.00 due to California Senate Bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52071	18041-10000-34690	350 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-2D-CPIO	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.76597	-118.28432	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52072	15041-10000-10973	2710 E MEDIA CENTER DR	90039	1	150B213  3658	5442032006	[Q]M2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Issued	04/21/2015 12:00:00 AM	PIN	34.10636393	-118.24150489	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 25761.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52073	17041-10000-30991	5531 W WASHINGTON BLVD	90016	10	126B177  1593	5064017001	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.03731	-118.36423	PC FOR OFFICE TI (E) TITLE-24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA 1967 SQ.FT. PERMIT IS REFER TO APPLICATION # 16041-30000-32232	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52074	14041-20000-22698	13849 N ELDRIDGE AVE	91342	7	228B157  1119	2503003005	(T)RE11-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.32363	-118.43232	PV1.  Install 4.16 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52075	18041-10000-12275	818 N HILL ST	90012	1	135A215   289	5408032026	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM			PC Info Complete	09/11/2018 12:00:00 AM	ADDRESS	34.06338	-118.23906	PC FOR Restaurant TI ON FIRST FLOOR OF THREE STORY HOTEL FOR T-24 ENERGY ONLY.SCOPE INCLUDES NEW PANEL, EQUIPMENT, LIGHTS. TOTAL AFFECTED AREA 2992 SQ. FTB#18016-100000-02848	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52076	14041-20000-02089	8011 N TROOST AVE	91605	6	189B169   199	2311005022	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.21605	-118.38644	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. USING SOLAR OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52077	11041-10000-02243	2230 W 6TH ST	90057	1	133-5A203 110	5141003900	OS-1XL	Central	Westlake	MacArthur Park	YES	2088.00	Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM	02/16/2011 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.06036	-118.27704	NEW PUBLIC RESTROOM. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52078	17041-20000-43969	17550 W EMBASSY DR	91316	5	171B129   318	2257008047	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.16329	-118.51589	PV1.  Install 21.125 kW roof mounted grid tied PV system.  (65) modules.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52079	14041-20001-20989	12540 W VOSE ST	91605	2	183B161   427	2324031008	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.19835	-118.40673	Change from previously approved plans.  Change the PV module model number from SW250 to SW280, and reduce the number of modules.  No change in Optimizers and Inverter.Note: Permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****New roof mounted PV system with Optimizers, total system size 7KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52080	19041-10000-16663	2504 N VIA ARTIS	90039	13	147A211   765	5443031021	(T)(Q)RD6-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.09757	-118.25134	Plan check for a PV1 5kw AC / 5.9kW DC roofmounted system with (1) inverter, (20) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52081	17041-10000-16567	3549 E SISKIYOU ST	90023	14	121-5A227 300	5188016023	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Expired	03/06/2024 12:00:00 AM	ADDRESS	34.0251	-118.19765	Installation of new roof mounted solar PV array.  Central inverter system.  Total system size = 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52082	17041-20000-14313	520 W MANCHESTER AVE	90044	8	097-5A201 280	6038001901	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	33.95992	-118.28343	Plan check for the installation of (2) temporary generators for existing pumps at a Public Works pumping plant. Temp generators will be used while the previously permitted back-up generator and ATS are being installed.Scope of permit is for temporary (1) day installation.  Note: Permit for the permanent back-up generator and ATS has been pulled under 15041-10000-24894	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52083	17041-30000-00822	8020 S DUNFIELD AVE	90045	11	099B165   424	4109008028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	33.96837	-118.39966	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3 kWac.  Central inverter system with DC optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52084	12041-10000-15657	9641 N ODESSA AVE	91343	12	201B137   705	2677006006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.24586	-118.49196	Plan check for PV System. SIngle Family dwelling. 7.848 kW DC. Transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52085	19041-20000-07213	13356 W WASHINGTON BLVD	90066	11	108B153  1311	4230008056	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	PIN	33.99199935	-118.44390738	Tenant improvement to (E) retail - plan check for energy 1316 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52086	14041-20000-11635	334 S MAIN ST #5002	90013	14	129A213   129	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.04841	-118.24668	CHANGE OF USE FROM RETAIL TO RESTAURANT. LOAD LESS THAN 400A. PC FOR T24 ENERGY ONLY. NEW LIGHTING. PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52087	13041-20000-01329	2029 S CENTURY PARK EAST 1010	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	34.05956	-118.41375	Change to lighting in conference room on the 10th floor of an existing office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52088	15041-20000-01024	3125 S LA CIENEGA BLVD	90016	10	123B173  1581	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.02985	-118.37256	T.I. to existing building.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy.due to building submittal, pc in accordance to 2008 energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52089	12041-10000-04910	8500 W BEVERLY BLVD # 678	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	remodel retail space #678 ( sunglass hut ) at the beverly centerplan chk is for title 24 compliance	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52090	15041-20000-30860	1975 E ZONAL AVE ROOM 405	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.06159	-118.20463	TI-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (USC). SCOPE INCLUDES NEW  LIGHTING AND A NEW PANEL. TOTAL AREA IS 102 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52091	16041-20001-13183	22960 W CALABASH ST	91364	3	168B097   150	2074026002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2016 12:00:00 AM			PC Approved	04/23/2016 12:00:00 AM	ADDRESS	34.15951	-118.62815	Expedited per applicant request.Plan check for an addition of a PV1 roof-mounted 3 kWac PV system onto an existing system. PV addition consists of (1) inverter, (10) modules, and (1) load center. Total system size is 9 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52092	17041-20001-30167	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.21445	-118.48429	4/4/2018changes to an approved set of plans.  changes noted delta 1.  changes to downsize total  system size to 360kw AC.  Ground mounted portion of the system is 60kw AC consisting of (1) inverter, (204) modules, and (1) load center.This is plan check only. ((((Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size is 400 kWac. Ground-mounted portion of the system is 124 kWac and consists of (3) inverters, (404) modules, and (1) load centers.Note: Building permits for the ground-mounted carport system have been issued under building permits 17010-30000-03239/03464/03465. Roof-mounted portion of the system has application number 17041-20000-30164.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52093	18041-10000-43680	3638 S MOTOR AVE	90034	5	120B161   825	4314007017	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			11/14/2018 12:00:00 AM			PC Info Complete	07/31/2019 12:00:00 AM	ADDRESS	34.02409	-118.40653	FULL PLAN CHECK FOR LOW RISE 6 STORY 63 UNIT APARTMENT BUILDING SCOPE OF WORK INCLUDES 1 SERVICE SIZE OF 1600 AMP WITH 2 TYPICAL UNITS. TOTAL SQFT IS 30546 BUILDING # 16010-10000-03000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52094	17041-20001-17313	11807 W LAUREL HILLS ROAD	91604	2	159B169    70	2377004020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.13566	-118.38965	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on a SFD.13.2kW ungrounded system. (44) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52095	17041-10000-08419	630 S LOS ANGELES ST	90014	14	127-5A211 119	5148022011	C2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.04387	-118.2495	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 186,275 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52096	16041-20002-05773	1377 N SERRANO AVE FLOOR 1-3	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Approved	01/11/2017 12:00:00 AM	ADDRESS	34.0965	-118.30717	01/11/2017 Changes to an approved set of plans. Lighting control system has been changed from WattStopper to Leviton and the split bus panel detail has been deleted.[[[[CHANGES TO APPROVED SET. CHANGES TO  SINGLE LINE ARE CLOUDED IN 3 SEPARATE PAGES . CHANGES TO FEEDERS BACK TO CORE AND SHELL SIZES.   CHANGES IN 1ST PAGE FLOOR 1, 2ND PAGE FLOOR 2, 3 PAGE FLOOR 3.  AS-BUILT DESIGN - CHANGES AFFECT SLD ONLY.]]]Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement/chance of use from motion picture film editing to office to floors 1 - 3 (building has a total of 6 floors). Total lighting area = 62,311 sq. ft. PLANCHECK ONLY FOR ALL 3 FLOORS.PERMIT FOR 1st FLOOR  UNDER  # 16041-20000-08761 ( 1ST FLOOR: 20,823 SQFT)PERMIT FOR 2ND FLOOR UNDER #16041-20000-08764 ( 2NDFLOOR: 20,986 SQFT)PERMIT FOR 3RD FLOOR UNDER #16041-20000-08766 ( 3RD FLOOR: 20,502 SQFT)Note: Building application has been generated under 16016-10000-03638 (1st Floor), 16016-10000-03605 (2nd Floor), and 16016-10000-03607 (3rd Floor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52097	13041-10000-06986	9131 N OAKDALE AVE	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.23697	-118.56716	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. NOTE: TITLE 24 PART 6 LIGHTING PERMITS SHALL BE OBTAINED THROUGHT THE ELECTRICAL PLAN CHECK COUNTER. T.I. to create  corridor within (e) Office/MFG bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52098	16041-30000-31127	5025 S MCKINLEY AVE	90011	9	111A207   261	5108013004	R2-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	33.99679	-118.26099	Plan check for Title 24 only in existing space, remove outdoor HID lighting fixtures and replace with new LED lighting fixtures. Total area: 19,590 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52099	19041-10000-49101	317 S BROADWAY A-1	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.05069	-118.24861	PLAN CHECK FOR TITLE 24. TOTAL SQUARE FOOTAGE FOR AREA: 350 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52100	17041-10000-45523	9640 N OWENSMOUTH AVE	91311	12	201B105   205	2746015006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.24548	-118.60221	PC FOR POWER AND ENERGY; FOR A TI AND CHANGE OF USE FROM WAREHOUSE/OFFICE TO MOTION PICTURE PRODUCTION; SCOPE INCLUDES ADDING NEW SECTION TO EXISTING SERVICE (2500A 277/480)ALSO NEW PANELS EQUIPMENT CIRCUITS AND LIGHTS TOTAL AFFECTED AREA 72000 SQ.FTB#17016-10000-08963	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52101	19041-10000-38439	2175 W JOHN S GIBSON BLVD	90731	15	024B197   394	7440016911	PF-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	33.75725	-118.28938	PC for fire alarm system for a homless shelter. (1) FACP, (1) communication panel, and (40) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52102	14041-10000-31037	3500 W 6TH ST 238	90005	10	135B197  1110	5502030016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM			PC Approved	11/07/2014 12:00:00 AM	PIN	34.06293154	-118.29881515	T.I. IN COMMERCIAL RETAIL SPACE.  PLAN CHECK FOR ENERGY.  PERMIT ALREADY OBTAINED UNDER 14041-30000-25605.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52103	12041-10000-24034	901 S FLOWER ST	90015	9	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.04579	-118.26176	TI on the first floor for a studio design. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52104	17041-20000-32256	7253 N LURLINE AVE	91306	3	186B109   974	2113015006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.20263	-118.58426	Plan check for solar pv system, roof-mounted on SFD.7kW ungrounded system [(1) 4kW + (1) 3kW].(26) 285W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52105	19041-20000-14919	10737 W HORTENSE ST 1-9	91602	2	168B177   784	2421024004	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Apartment			04/23/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.15487	-118.36502	New 9-unit 4-story apartment building.  800A 240/120V 3ph-4w service.  Building permit under 18010-20000-00247.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52106	17041-10000-40161	620 W AVENUE 27	90065	1	144A219   390	5453011020	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.08692	-118.22469	Remove HID fixtures and replace with new LED fixtures  T-24 only.10100 SQ.FT.  OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52107	17041-10000-30889	710 E PICO BLVD STE  107	90021	14	123A211    85	5132019005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.03237	-118.25355	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURE T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52108	14041-20000-26076	14731 W HAGAR ST	91345	7	210B149   157	2664011037	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.2754	-118.45355	PV1.  Install 5.8 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52109	14041-20000-14506	4300 N BECK AVE	91604	2	165B169   594	2365027014	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.14741	-118.38321	Roof mounted PV system size 6.75KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52110	19041-20000-11793	11100 W SANTA MONICA BLVD	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Issued	06/21/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	T24 PLAN CHECK FOR EXSITING PARKING STRUCTURE, CHANGE/UPGRADE OF LIGHTS FROM FLOURESCENT TO LED FOR NORTH PARKING STRUCTURE ONLY. TOTAL SQUARE FOOTAGE = 254,940SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52111	14041-10003-08594	1288 N ANGELO DR	90077	5	144B153   281	4357014006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.09339	-118.43608	Fee is $0.00 due to Senate bill No. 1222. Change to approved set by removing (1) Existing 200-Amp breaker on the designed plan. The only change is under the clouded area only.(((Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0..PV1 14.04KWdc. 240V. microinverter. STD. 1story. Roofmount. [(52) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(52)modules: {mono lg270s1c-a3}]     )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52112	15041-10000-19494	333 S ALAMEDA ST # 222	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.04448	-118.23824	ALTERATION INA VETERINARY CLINICPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52113	17041-20000-45509	11645 W WILSHIRE BLVD Ste 600	90025	11	129B145   489	4265001036	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.05013	-118.46034	Additional distribution for equipment branch for eye clinic facility in existing commercial highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52114	13041-10000-35677	5467 W 8TH ST	90036	4	132B181   203	5089003033	R3-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.06071	-118.34849	PLANCHECK FOR POWER AND ENERGY.  PLAN CHECK PER APPLICANTS REQUEST. 1 BUILDING ACCORDING TO APPLICANT. HOUSING FOR NUNS. 13014-10000-05096 RENOVATION AND ADDITION TO EXISTING  PROVENCIAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52115	19041-10000-30307	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	11/03/2021 12:00:00 AM	ADDRESS	33.98076	-118.40716	PC FOR A NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. SCOPE INCLUDES 263 FA DEVICES, AND 6 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52116	16041-10000-36174	10250 W SANTA MONICA BLVD STE. 1830	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM			PC Info Complete	11/10/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Kookai "" Ste. 1830.  Install new 15KVA transformer and 2 panels < 200 each, total effected area: 2,432 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52117	11041-10000-12901	1800 E OLYMPIC BLVD	90021	14	121-5A215  93	5166026036	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.02736	-118.23883	CHANGE USE/OCCUPANCY:  Remodel of existing auto repair bays to new 7-11 Store.  Gas service to remain.  Canopy to remain.  EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52118	14041-10000-01839	11135 N VIKING AVE	91326	12	210B121   293	2717004026	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.27217	-118.5426	PV1 6.45KWdc. 240V. microinverter. STD. 1story. Roofmount. [(30) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(30)modules: {solarworld SunModule SW-250 mono }]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52119	12041-10000-00761	6080 W CENTER DR 6TH FLR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	ADDRESS	33.97713	-118.39172	PLAN CHECK FOR T24 ENERGY MANDATORY MEASURES FOR TENANT IMPROVEMENT EXISTING OFFICE 6TH FLOOR. PERMIT FOR RELOCATE AND REPLACE LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52120	12041-10000-14217	10504 W WILSHIRE BLVD	90024	5	135B157   424	4326003020	[Q]R5-3	West Los Angeles	Westwood	Westwood		2656.00	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.06391	-118.43211	New Fire alarm for an existing Temple.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52121	19041-20000-03377	10824 W BURBANK BLVD	91601	2	174B173  1015	2416014016	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM			Plans on Hold	03/01/2019 12:00:00 AM	ADDRESS	34.17199	-118.3668	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW OFFICE. SCOPE OF WORK INCLUDES NEW 1200AMPS SERVICE,208/120 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 11332 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52122	16041-10000-17525	1840 S CENTURY PARK EAST 3rd floor	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Closed	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	OFFICE TI TO 3RD FLOOR. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52123	17041-20002-38052	660 S VETERAN AVE	90024	5	135B149   467	4363013038	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.06501	-118.45379	Revisions to approved set.  Change of module type to 320W version, module count to (120), change of inverter system to (2) 14.4 kW SolarEdge 3 phase inverters.  Revised SLD details and wiring.  (((Plan check for solar pv system, roof-mounted array on apartment building.Total system size: 32.4kW ungrounded.(2) 9kW SolarEdge inverters.(1) 14.4kW SolarEdge inverter.(125) 275W pv modules.(125) 300W power optimizers.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52124	18041-10001-28536	5500 W JEFFERSON BLVD	90016	10	120B173  1730	5047015033	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			Corrections Issued	01/02/2020 12:00:00 AM	ADDRESS	34.02557	-118.3665	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE LOCATION AND REMOVAL OF DEVICES - ALL CHANGES HAVE BEEN CLOUDED UNDER DELTA 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52125	12041-10000-06151	12059 W OSBORNE ST	91331	7	210B165   543	2532017066	(T)(Q)C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.06	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.2726	-118.39552	PLAN CHECK FOR NEW 3 STORY 42 UNIT APARTMENT BUILDING (BLDG 1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52126	19041-20001-35360	5919 N RESEDA BLVD	91356	3	177B125   808	2156025022	R3-1	South Valley	Encino - Tarzana	Tarzana		1393.02	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM			Reviewed by Supervisor	09/19/2019 12:00:00 AM	ADDRESS	34.17806	-118.53633	Expdite per appliant request Plan check for PV roof mounted system, PV system size: 12.96KW with 32 PV Modules and 1 inverter(10.0KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52127	18041-20000-14953	1558 E 25TH ST	90011	9	117A213   207	5118018005	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.01513	-118.2449	Plan check for power only in existing building upgrade to 800A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52128	19041-20001-21601	5005 N EDENHURST AVE	90039	13	162B201    20	5593012032	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.142	-118.2736	EXPEDITED PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS 66.6KW DC/66.6KW AC.SCOPE OF WORK INCLUDES (180) HYUNDAI SOLAR MODULES WITH (90) P850 OPTIMIZERS, AND A SE66.6K INVERTER2 PERMITS ON SAME PLAN, SECOND PERMIT IS 19041-20000-21615PROJECT IS A (E) COMMERCIAL BUILDING WITH 2 NEW CARPORTS AND 3 SOLAR ARRAYS WITH 2 POINTS OF INTERCONNECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52129	15041-10000-18900	200 WORLD WAY # 239	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	SIGN LIGHTING FOR CNBC, POWER SUPPLY EEFICIENCY >80%.  PLAN CHECK FOR ENERGY ONLY.  CONTROLS AND WIRING TO BE UNDER SEPERATE PERMIT BY GC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52130	19041-10000-13129	4800 S ALLA ROAD	90066	11	105B157   569	4223008010	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	33.98292	-118.42948	Plan check for a new fire alarm system located in a new 2-story office building (core and shell only). Scope includes (1) fire alarm panel, (1) control panel, and (48) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52131	12041-10000-09950	400 S WESTERN AVE 1-2	90020	4	135B193   439	5503014023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.01	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.067	-118.30888	upgrade sevice supplying commercial building; existing 800a swbd be supplied from new service with new 1200a swbd; loads on 800a swbd  are existing; house panel will be supplied from new swbd	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52132	19041-20000-10429	11705 W VENTURA BLVD	91604	2	162B169   335	2368006025	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Issued	03/22/2019 12:00:00 AM	ADDRESS	34.14159	-118.388	T24 PLAN CHECK FOR EXISTING RETAIL LOW RISE, LIGHTS AND OUTLETS ONLY USING EXISTING BRANCH CIRCUITS, TOTAL SQUARE FOOTAGE = 3919SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52133	12041-10000-17195	9233 N MONOGRAM AVE	91343	12	198B137   660	2676022023	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.23844	-118.49282	New 7.92kw rooftop mounted photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52134	15041-10000-27102	12460 W OSPREY LANE 1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	PV2 ROOF MOUNTED. TOTAL SYSTEM SIZE 1.84 KW ON COMMERCIAL 4-STORY BUILDING (BUILDING 8 UNIT 22) UNIT ONE (8) MODULES: SUNPOWER MODULES SPR-230NE-BLK-D(1) INVERTER PVI3.0 OUTD-S-US-A (POWER ONE) 240VACZONING CLEARANCES FOR UNIT 1,2, AND 3 INCLUDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52135	17041-10002-29734	1630 W 186TH ST	90248	15	060B193   248	6108002022	P-1VL, [Q]MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM			PC Approved	07/03/2019 12:00:00 AM	ADDRESS	33.86187	-118.30705	Change to approved set by modifying the single line diagram and floor plan with fault and disconnects updated. All changes under delta-H only.(((PC for power and energy for new outdoor Hydrogen gas dispensing facility for Toyota(No public access). PC includes installation of vehicle fuel dispensing, fuel storage, air compressors and device control panel with control diagram on pg E6.1. Total area of 5723 sqft.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52136	16041-10000-12845	189 S THE GROVE DR STE G-5	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE FOR THE GROVE, SUITE G-5. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, ONE NEW 75KVA,  AND ONE NEW 225A PANEL. TOTAL AFFECTED AREA IS 3075 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52137	19041-10000-13367	14718 W HART ST	91405	6	183B149   408	2219015009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.19744	-118.45377	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 18 MODULES (QCELL 285) , 18 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 5.13KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52138	12041-20000-12498	20628 W VINTAGE ST	91311	12	204B109   505	2741028052	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.25164	-118.58297	Photovoltaic system on roof of single family dwelling using enphase inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52139	14041-20001-04719	5525 N ETIWANDA AVE SUITE 112	91356	3	174B125   518	2160011026	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.17048	-118.53094	SUPPLEMENTAL APPLICATION. FULL PLAN CHECK FOR 517 HEALTH CARE, PATIENT CARE ROOMS. SUPPLEMENTAL FROM T24 APPROVED SET OF PLANS. THIS APPLICATION WILL COVER PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52140	13041-10000-11584	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	TENANT IMPROVEMENTS/ REMODEL. ADD (2) NEW 120/208V, 150A PANNELBOARDS TO SERVE NEW YORK. pLAN CHECK FOR POWER AND TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52141	19041-10000-17307	7913 S KENTWOOD AVE	90045	11	099B165   197	4109018017	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	33.9703	-118.40209	[E-plan] Install 2 Energy Storage Systems @27KWH total & 1 New 125A Load Center & (1) 200A Sub Panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52142	12041-10001-08396	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Expired	05/20/2015 12:00:00 AM	ADDRESS	34.14246	-118.2705	New fire alarm system for a 2-story healthcare office building.((((((((((((((( 4-25-13   changes made to previously approved set , added some devices and deleted some.)))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52143	19041-20001-28683	625 N KINGMAN AVE pv1	90402	11	124-5A133 153	4408034023	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	08/12/2019 12:00:00 AM	ADDRESS	34.03507	-118.50885	expeditepv1install roof mounted pv system sized 4.9KW Ac interconnected with msp.(1) tesla ESS rated at 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52144	15041-10000-24189	8731 S LINCOLN BLVD	90045	11	096B161   737	4119026038	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	33.95818	-118.41793	Full plan check for interior remodeling; Scope include new lighting, eqpuipment and receptacle. Total (10) panels, (100) circuits, and 27,284-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52145	19041-20001-38648	2071 W RIDGEVIEW AVE	90041	14	159A223    41	5685018017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.13147	-118.21282	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO SITE PLAN, RELOCATING PV MODULES, CHANGE TO SIGNAGE PAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52146	14041-20000-27838	700 S FLOWER ST SUITE 2650	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Issued	10/09/2014 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING LIGHTING AND RECEPTACLES.  USING EXISTING POWER EQUIPMENT.  WORK TO BE PERFORMED IN THE 26TH FLOOR SUITE 2650.4300SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52147	15041-20000-39285	1680 N VINE ST #612	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.10133	-118.32648	PLANCHECK FOR TITLE 24 ENERGY ONLY. OFFICE TI. HIGHRISE. MODIFICATION TO USE UNIT EQUIPMENT EXISTING UNDER 09016-10000-14109. SUITE 612	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52148	16041-20000-05796	1999 S BUNDY DR 2nd Floor	90025	11	123B149   406	4259019007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.03406	-118.45593	TI to (E) 2nd-story commercial office space in (E) lowrise office building.  Plan check for energy only.  Alteration of (E) lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52149	11041-10000-11146	3450 S WATT WAY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	06/10/2011 12:00:00 AM	ADDRESS	34.02275	-118.28604	T.I.  Crating two seperate areas for the USC School of Music.  Plan check is for Energy and Emergency Lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52150	13041-20001-35802	3501 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM			PC Approved	05/14/2014 12:00:00 AM	ADDRESS	34.02194	-118.28455	Changes from previously approved plans.  Change in the type of light luminaires.  Plan check for energy only.Note:  Permit is under a separate application.*****Previous Description*****T24 FOR OFFICES AT USC. SCOPE OF WORK ON NORTH SIDE OF THIRD FLOOR AND SOME OFFICES ON THE FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52151	17041-10000-29816	19640 W HORACE ST	91311	12	207B117    89	2708011012	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Issued	10/06/2017 12:00:00 AM	ADDRESS	34.26696	-118.56196	Permit fee is $0.00 due to Senate Bill 1222.PC FOR ROOF MOUNTER PV (WITH BATTERY) ON SFD. TOTA L PV SIZE 19.8KW DC / 18.2KW AC. CENTRAL INVERTER SYSTEM. SCOPE INCLUDE 63 PV MODULES WITH OPTIMIZERS2 (DC SIDE) BACK UP BATTERIES, 3 SUBPANELS, (2) 7.6KW INVERTERS AND (1) 3KW INVERTER. (BACKUP AND LOAD CENTER).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52152	16041-10000-22165	11845 W OLYMPIC BLVD 9TH FLR	90064	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.03291	-118.45177	TI on the 9th floor Corridor. Install new lights using existing circuits, PC for T-24 only. Total area: 1,530 sq.ftB# 16016-30000-11010	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52153	15041-10000-38339	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	33.79072	-118.29449	PC FOR T24 ENERGY ONLY. CHANGING OUT FIXTURES IN COMMON AREAS. NO OTHER WORK BEING DONE. WORK ONE ON LEVELS 1-3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52154	14041-20000-22612	12016 N YOUNGDALE AVE	91342	7	216B149   427	2611024010	RS-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.28835	-118.45712	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(17) SolarEdge P300 power optimizers(17) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52155	16041-20001-16310	4047 N ELLENITA AVE	91356	3	162B117    47	2180004033	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.14379	-118.55994	EXPEDITE PER APPLICANT REQUEST{{{{PLAN CHECK FOR PV ROOF MOUNTED SYSTEM. SYSTEM SIZE: 15KW WITH 45 MODULE AND 2 INVERTER(7.6KW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52156	17041-20001-43713	8421 N ZEILER AVE	91402	6	192B157   493	2637014056	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.22353	-118.42553	Expedite plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52157	18041-10000-06412	415 N LOS ANGELES ST 1ST FLR	90012	14	132A215   110	5408008905	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM			PC Info Complete	04/27/2018 12:00:00 AM	ADDRESS	34.05553	-118.23933	08/14/2019 VOID- Under new application number. E.CT.I. FOR EXISTING MUSEUM (1ST FLOOR)- new feeder with xfmr/panelboard/new circuitsPLAN CHECK S FOR TITLE 24 AND 1 EA EMERGENCY CKTTOTAL AFFECTED AREA 2967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52158	16041-20000-27510	15239 W LA CRUZ DR	90272	11	129B125   795	4412002017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.04564	-118.52549	INSTALLATION OF A FIRE ALARM SYSTEM.  1 FACP, 27 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52159	19041-20000-24709	3009 S PATRICIA AVE pv1	90064	5	123B161   233	4318022027	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Issued	06/26/2019 12:00:00 AM	ADDRESS	34.03599	-118.41294	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52160	13041-10001-27191	4550 W PICO BLVD #D-303	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.04842	-118.33486	REVISIONS TO LIGHTING PLAN AND TO POWER PLAN; REVISIONS ARE CLOUDED ON THE PLANSPLAN CHECK POWER AND ENERGY FOR SMART & FINAL STORE (SUITE D-303)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52161	13041-10000-10628	255 E ADAMS BLVD	90011	9	120A207   122	5127036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.02379	-118.2657	PERMIT IS FOR EXISTING BRANCH CIRCUITS, LIGHTING LOADS AND TWO RECEPTACLES ON EXISTING BRANCH CIRCUITS, AND TWO NEW CONDENSER UNITS.**********************************************************RENOVATION OF EXISTING LIQUOR STORE. INSTALLATION OF NEW LIGHTING. MINOR CHANGES IN POWER. PLAN CHECK FOR T24 ENERYG ONLY. TOTAL AREA 2720 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52162	17041-10000-13016	101 N LA BREA AVE	90036	5	138B181   828	5513002001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.07377	-118.34423	PC for energy only for interior TI retail store. Indoor Title-24. no change in use or occupancy. New lighiting and power. Area: 1310 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52163	14041-10000-25759	12751-12775 W MILLENNIUM 4150	90094	11	102B161  1175	4211033020		West Los Angeles				2756.02	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT. TOTAL AREA( 5596 INDOOR+ 1170 OUTDOOR) Q FT.B# 14016-10000-14645.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52164	17041-10001-09444	10250 W SANTA MONICA BLVD #1940	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			PC Approved	07/20/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1ST REVISION TO APPROVED SET FOR RETAIL ""PENHALIGON'S""  IN WESTFIELD CENTURY CITY. SUITE 1940. SCOPE INCLUDES REVISE LIGHT FIXTURE, UPDATE T24 INFORMATION, ADD AND REMOVE LOADS FROM PANEL L. This is Plan Check only, permit is covered under master plan check#"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52165	19041-10000-21150	15359 W OXNARD ST	91411	6	177B145   440	2242001020	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.17957	-118.46823	POWER PLAN CHECK FOR INSTALLING A MANUAL TRANSFER SWITCH TO EXITING 2000A 480/277 SWITCH BOARD. THIRD PARTY EQUIPMENT RELISTING MAY BE REQUIRED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52166	13041-20000-10761	541 N ROCKINGHAM AVE	90049	11	135B137   430	4406004004	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Expired	07/22/2015 12:00:00 AM	ADDRESS	34.06523	-118.49074	single family new	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52167	15041-10000-36114	764 N TERRACE 49	90042	1	153A223   397	5471015024	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM			PC Info Complete	10/28/2015 12:00:00 AM	ADDRESS	34.11165	-118.20945	Void.... PV1, INSTALL 3.0 KW DCROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: HYUNDAI SOLAR (1) INVERTER: ABB PVI-3.0-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52168	17041-20000-23788	11133 S AVIATION BLVD	90045	11	087B173    99	4129037908	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Closed	10/09/2018 12:00:00 AM	ADDRESS	33.93246	-118.37734	Relocate portable rock crushing plant (originally permitted under 17041-20000-10033 -- relocating feed to 3000A main switchboard).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52169	15041-10000-25050	1337 S FLOWER ST 1st fl	90015	14	126A205    70	5134010008	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.0391	-118.2677	REMODEL EXISTING OFFICE SPACE SO AS TO BE USED AS TEMPORARY CONSTRUCTION OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52170	18041-10000-05065	332 S AVENUE 17	90031	1	136-5A219 125	5447029010	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.06837	-118.22168	PC FOR TITLE 24 ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A WAREHOUSE. TOTAL AFFECTED AREA IS 9000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52171	15041-20000-22331	1506 W 12TH ST	90015	1	127-5A203  34	5137029019	C2-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.04543	-118.27458	Plan check for Title 24 only. Project site is an existing 2-story commercial building. Project scope is a tenant improvement. Total lighting area = 2,491 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52172	19041-10000-20978	1541 S CENTRAL AVE	90021	14	121-5A211 260	5132023027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Issued	06/04/2019 12:00:00 AM	ADDRESS	34.02676	-118.24871	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52173	13041-10000-01868	6151 W PICO BLVD	90035	5	129B173    23	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM			PC Approved	01/24/2013 12:00:00 AM	ADDRESS	34.05337	-118.37542	EXISTING BLDG >SHELL. PC FOR ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52174	14041-10000-02401	1015 S CROCKER ST #R-15	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	Remove HID light fixtures and replace with new fluorescent fixtures in retail space.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52175	12041-10000-23843	6148 W 75TH PL	90045	11	102B165   870	4106007021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2012 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	33.97212	-118.39371	NEW PV ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52176	15041-10000-16286	1755 N HIGHLAND AVE	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.10323	-118.33897	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTIN NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK IN THE RESTAURANT RESTROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52177	17041-20000-02645	100 WORLD WAY SUITE 120	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLANCHECK FOR T24 ENERGY. SIGN LIGHTING FOR REILLY'S IN LAX. SUITE 120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52178	18041-20000-01271	5363 N BALBOA BLVD Suite 111	91316	5	171B133    38	2258027016	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.16893	-118.50129	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvment to a medical office. Total lighting area = 1,541 sq. ft.Note: Building application has been generated under 17016-40000-32208	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52179	16041-20000-05709	12751 W MILLENNIUM B 5115	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Issued	04/12/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. LIGHTING ONLY IN BATHROOM, REST TO BE FUTURE TI. BUILDING B, UNIT 5115.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52180	11041-20000-14883	4151-4155 W BEVERLY BLVD	90004	13	138B197   319	5520025006	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20, 2112.00	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.07643	-118.2996	Plan check for new 600A service and upgrade and new panels to existing commercial building. All loads are phase 2 submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52181	17041-10001-36932	5850 W 3RD ST unit A,B	90036	4	135B181   171	5509002015	C2-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.06907	-118.34746	PC PER APPLICANT REQUEST. SCOPE INCLUDES  CHANGE TO VOLTAGE CLASS OF PANELS TO REFLECT ON SITE EXISTING INSTALLATION OF 120/240V. THIS IS PLAN CHECK ONLY!PC FOR RESTAURANT TI  FOR TITLE 24  ENERGY ONLY.SCOPE INCLUDS NEW CIRCUITS LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 1609SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52182	17041-10000-40613	6500 N SEPULVEDA BLVD	91411	6	180B145   564	2235002007	R4-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Public Safety Only			11/09/2017 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	08/14/2020 12:00:00 AM	ADDRESS	34.1886	-118.46595	NEW FIRE WARNING SYSTEM FOR A 160 UNITS 6-STORIES APARTMENT BUILDING. SCOPE INCLUDES 579 FA DEVICES, AND 1 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52183	14041-20001-29403	6701 S CENTER DR WEST SUITE 700	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Expired	05/08/2017 12:00:00 AM	ADDRESS	33.97907	-118.39369	Change to approve set of plan. Changes apply to delta 4 only*********TI TO AN EXISTING HIGH RISE BUILDING.  ADDING LIGHTING TO EXISTING POWER EQUIPMENT.  WORK TO BE DONE IN SUITE 700.   5390 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52184	16041-20001-00846	13117 W CORCORAN ST	91340	7	216B161   331	2514017008	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM	ADDRESS	34.28716	-118.4188	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6.5 kWac and consists of (26) modules, (26) micro-inverters, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52185	10041-10000-14138	825 W BLOOM WALK	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.01915	-118.28686	TI - LAB IMPROVEMENTS @ 1ST FLR ROOMS 103, 107, 109 & 112 - , title 24 and emergency lighthing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52186	18041-20000-17584	13700 W RIVERSIDE DR 1st floor	91423	4	168B157   318	2269025002	C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.15744	-118.43168	Plan check for Title 24 Energy only, in existng Bank Of America T.I. Total area: 4452 sq ft.B#18016-10000-13879	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52187	11041-20001-18555	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.02	Electrical	Electrical	Public Safety Only			03/08/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.20696	-118.3417	added smoke detectors to existing permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52188	16041-20000-32089	6345 N VARIEL AVE	91367	3	180B105    66	2149001032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM			Verifications in Progress	11/02/2016 12:00:00 AM	ADDRESS	34.18643	-118.5936	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 476 KW. LINE SIDE TAP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52189	16041-30000-16374	18925 W SATICOY ST	91335	3	186B121   153	2104013034	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.20852	-118.54595	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52190	18041-20000-00522	6080 W CENTER DR 7th Floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	33.97713	-118.39172	TI to (E) commercial restroom space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52191	16041-20000-40960	10258 ANGEL LANE	91331	7	204B165   425	2537004035	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25715446	-118.40460319	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52192	12041-10000-16683	333 S ALAMEDA ST	90013	9	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.04448	-118.23824	full plan check per owners request, title 24 and emergency lighting, 5 new panel , arcade, restaurant, bowling. must use area catagory. plann check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52193	17041-10000-03431	4041 N WHITSETT AVE	91604	2	162B165  1118	2375018904	A1-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.14437	-118.40544	PC for outdoor title 24. Removign HID fixtures and repalcing them with new LED ones. Area: 26,800 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52194	14041-20000-09234	9803 W CRAIGMITCHELL LANE	91040	7	207B181   262	2549024027	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.26023	-118.34493	PV1.  Install 4.5 kW roof-mounted PV system.  18 modules: ET Solar ET-P660250BB.  Transformerless inverter: PowerOne PVI--3.8-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52195	15041-10000-26171	854 S OXFORD AVE	90005	10	132B193   845	5093010002	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			08/12/2015 12:00:00 AM	10/05/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.05611	-118.30765	PC FOR POWER ONLY. REPLACE EXISTING SUBPANEL TO EACH UNIT. (72) UNITS TOTAL. EXISTING SERVICE , AND EXISTING DISTRIBUTION BOARD.permit for 61 panels was obtained on 15041-10000-11593	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52196	19041-10000-44916	515 S FLOWER ST SUITE 5050	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES LOADS. TOTAL SQ. FT. 3493.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52197	15041-20000-14689	7032 N ENCINO AVE	91406	6	183B129   421	2228027006	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.19846	-118.51408	Plan check for PV system  roof mounted 4.0kWac system with 18 modules and 18 micro-inverter(Enphase )	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52198	16041-10000-00297	10901 W RIVERSIDE DR	91602	4	165B173    48	2423009049	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Mid-Town North Hollywood		1432.00	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.15243	-118.36779	T-24, TI TO THE DINNING AREA IN AN (E) RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3314	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52199	17041-10000-18110	18411 W VINCENNES ST	91325	12	198B125   135	2764010026	R3-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.24105	-118.53394	REMOVE EXISTING HID FIXTURES AMD REPLACE WITH NEW HID FIXTURES - TOTAL OF 6 FIXTURES. SQ. FT. 11825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52200	18041-20000-39365	11801 W OLYMPIC BLVD	90064	11	123B149   392	4259023006	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.03317	-118.45051	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52201	16041-20000-03568	617 N SAN PASCUAL AVE	90042	14	154-5A235 192	5716027003	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.04	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.11754	-118.17357	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. Each module has a 300W power optimizer.(19) 270W pv modules. Using a standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52202	13041-10000-19814	377 N DOUGLAS ST 1-4	90026	1	136-5A209 308	5160008022	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			07/25/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.06674	-118.25719	PV1.  Install 3.675 kW DC roof-mounted solar array and interconnect with main service panel.  {Transformerless inverter: Power-One Aurora PVI-3.0-OUTD-US} {15 modules: Trina Solar TSM-245PC05/PA05.18}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52203	15041-20000-41347	15233 W VENTURA BLVD #500	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.1538	-118.46502	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 5TH FLOOR. OFFICES. PER APPLICANT NEWLY CONNECTED LOAD >400 AMPS .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52204	14041-10006-35068	1311 W SEPULVEDA BLVD	90501	15	045B193   791	7347018097	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM			PC Approved	02/07/2018 12:00:00 AM	ADDRESS	33.81492	-118.30044	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. CHANGES INCLUDES REVISED T-24 FORMS AND RECEPTACLES ARRANGMENT AND TYPE (INCLUDING TV RECEPTACLES).THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52205	14041-10000-11760	18881 S HOOVER ST	90248	15	060B201    31	6121020010	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	33.86411	-118.28622	T24, Remove HID light fixtures and replace with new florescent fixtures.  Total area 23411 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52206	11041-10000-13012	201 S WOODBURN DR	90049	11	135B145   250	4365004035	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2011 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Expired	08/08/2014 12:00:00 AM	ADDRESS	34.0684	-118.46741	New 2 story single family residence with new 600 amps service.   Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52207	19041-10000-30850	7100 N TUJUNGA AVE	91605	2	183B173   138	2319001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.19969	-118.37887	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52208	10041-10000-04690	10808 W KLING ST	91602	4	168B177   748	2421024016	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Public Safety Only			03/16/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	04/22/2010 12:00:00 AM	ADDRESS	34.15552	-118.36608	Installation of a fire alarm central station monitoring system for a 5-units apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52209	10041-30000-10104	1660 W 3RD ST	90017	1	133-5A205 153	5153008014	C2-1	Central	Westlake		YES	2091.04	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM			PC Info Complete	06/03/2010 12:00:00 AM	ADDRESS	34.06052	-118.26744	Core and shell for existing building and existing service change of occupancy. Lighting and power in commen area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52210	14041-20001-18651	9427 N COLLETT AVE	91343	12	198B141   156	2671015015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	ADDRESS	34.24177	-118.48403	Expedite per customer request(((PV1 10.2 roof-mounted system with (40) trina Solar TSM-255p modules and Solaredge p300 optimizers, (2) inverters se3800A and SE6000A connecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52211	15041-10000-16064	2462 W PICO BLVD	90006	1	129B197  1091	5056001001	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.04708	-118.29083	Full plan check for a change of use from retail to laundrymat; Scope include new 1200-Amp service and all equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52212	16041-20000-42848	15503 W VENTURA BLVD Ste 340	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.15504	-118.4723	Change of use from office to medical suite.  2054 sq ft. TI.  Plan check for power and energy.  Building permit filed under 16016-20000-20387.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52213	10041-10000-09516	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, [Q]R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.02	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.20696	-118.3417	Ti in  fabrication lab for Woodbury University. Plan check for T24 and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52214	14041-20000-20997	8623 N RUDNICK AVE	91304	12	195B101   404	2004021029	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.22751	-118.61183	New roof mounted PV system, total system size 11.12KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52215	10041-20000-10531	9711 N CANOGA AVE	91311	12	201B105   157	2746015002	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	07/06/2010 12:00:00 AM	ADDRESS	34.24665	-118.59942	energy plan check industrial	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52216	16041-20000-36644	5511 N CAHUENGA BLVD	91601	2	174B177   872	2416020038	CR-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.17036	-118.36172	ti to an existing commercial building.  adding new lighitng new controls to new panels.  newly connected load < 400 amps plan check for energy only.  total square footage 12526	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52217	18041-10000-15684	10966 W RATNER ST	91352	6	189B173   168	2409003015	[Q]C2-1L-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.22	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.21679	-118.36932	PC FOR POWER AND ENERGY FOR A NEW 4-STORY, 44 UNITS AFFORDABLE HOUSING. SCOPE INCLUDES NEW SERVICES, PANELS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 24895 SQ.FT.FIRE ALARM VARIENCE HAS NOT BEEN SUBMITTEDB#17010-10000-04614	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52218	15041-10000-12515	600 WORLD WAY TERM 6,	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR POWER AND ENERGY. TERMINAL 6 OF LAX. FIRST TIME TENANT ( SEE'S CANDY). TOTAL AREA 111 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52219	13041-20004-04124	616 S KENMORE AVE	90005	10	135B197  1102	5502028006	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.06289	-118.29646	10/16/2017 Changes to approved set of plans.  Approval for changes clouded and marked as Delta 5 only.  Deletion of standby generator supplying elevator.  (((06/28/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes include the addition of a subpanel, re-circuiting home-runs, and minor lighting changes.)))(((5/1/2017changes to an approved set of plans.  changes noted delta 2.  new generator with em lighitng and associated loads in the cooridors and outside podium level only.  general lighitng fixtures changed in common areas.  plan check for energy and power.  2008 title 24.))) (((((Full plan check for new 57 unit apartment. Fire alarm variance has been filed. METHANE Zone.extention granted to 8/19/15)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52220	17041-20000-09073	12700 W VAN NUYS BLVD Bldg 8	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	Plan check for a PV2 roof-mounted PV system. System size is 6 kWac and consist of (1) inverter and (25) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52221	17041-10000-33720	965 S NORMANDIE AVE	90006	10	129B193    50	5078001914	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.05367	-118.30011	Plan check for Title 24 only addition of kitchen space in 2nd floor community center. Total area: 535 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52222	18041-10001-06265	1030 N SWARTHMORE AVE 2-111	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	Change to approved set by changing the feeder and conduit size. All changes under delta-4 only..(((PC for power and energy for retail first time tenant. Installing new panel, lights, receptacles and equipment. Total 580sqft. B# 18016-10000-05243.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52223	13041-10000-07230	535 S CURSON AVE WEST Tower 49	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Issued	05/21/2013 12:00:00 AM	ADDRESS	34.06635	-118.35533	Service upgrade to 4000A for a 13-story apartment building (Tower 49).  Install new switchboards, feeders, house panels, and replace unit panels.  All the existing branch-cirucit conductors to be remained and reconnected to the replacement unit panels.  No work done on branch circuit equipment and lighting.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52224	14041-10001-30554	8000 W SUNSET BLVD ste B310	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			01/05/2015 12:00:00 AM			PC Approved	01/05/2015 12:00:00 AM	ADDRESS	34.09783	-118.36466	Change to approved set by removing 1 fixture (F) at the pantry area. all changes apply to Delta-1 only(((T24 total area = 3612sq ft.  Tenant improvement 3rd floor of existing commercial building.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52225	15041-10001-26135	2401 W BEVERLY BLVD	90026	13	136-5A203 160	5157010019	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.01	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	PIN	34.06858015	-118.27392721	Expedite per applicant request(((PV2 22.8KW roof-mounted system with (96) Hanwha Q-cells-265 modules, (3) Solaredge SE7600-US inverters, and (96) P300 power optimizers interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52226	13041-20004-35606	11995 W BLUFF CREEK DR BLDG #4	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	PC FOR CHANGES TO APPROVED SET OF PLANS. CHECKING FOR CHANGES TO AIC RATINGS AND FAULT CURRENT VALUES DUE TO CHANGE IN CONDUCTOR TYPE. NEW AIC RATINGS ON VFD AND RELOCATION OF CIRCUIT FOR SITE LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52227	17041-20000-11743	13790 W FOOTHILL BLVD 162-164	91342	7	222B153    30	2509019003	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			Reviewed by Supervisor	05/10/2017 12:00:00 AM	ADDRESS	34.30953	-118.43339	PLANCHECK FOR POWER AND ENERGY. INSTALLTION OF 1200AMP SWITCHBOARD AND TENANT IMPROVEMENT FOR 3 UNITS. UNIT 162-164	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52228	19041-20001-16713	24641 W CANYONWOOD DR	91307	12	183B085   109	2031010036	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/01/2019 12:00:00 AM	ADDRESS	34.19828	-118.66152	CHANGES TO APPROVED SET DELTA 2 ONLY. CHANGES APPLY TO LOAD CALCS. <<<Plan check for Battery back up system installed in to existing PV system, Battery system size: 13.5kWh>>> .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52229	19041-10000-29502	7501 S OGELSBY AVE	90045	11	102B165   507	4110020017	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	09/29/2021 12:00:00 AM	ADDRESS	33.97454	-118.40014	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.72KWdc / 8.757KWac.(27)MODULES- SOLARIA POWER XT-360R-PD(27)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SE 10000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52230	13041-20000-18110	3752 S OCEAN VIEW AVE	90066	11	114B153  1192	4248031053	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Expired	08/05/2015 12:00:00 AM	ADDRESS	34.00536	-118.43308	pv1 sinlge FAMILY DWELLING. TOTAL SYSTEM SIZE 5.88KW. USING TOTAL OF 24 PANELS. 2 STRINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52231	11041-10001-13142	960-968 E ELKLAND PL BLDG 1	90291	11	111B145   999	4243004036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/11/2012 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99855	-118.45949	REPAIRS & HISTORICAL REHABILITATION  / TI OF 17 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.(((((((((((((((((((((((((((((((((((((((( Addition of 7 new ckts for dettached garage. changes made to previously approved set.)))))))))))))))))))))))))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52232	19041-20000-10875	230 E 1ST ST	90012	14	130-5A215 337	5161017003	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Info Complete	03/26/2019 12:00:00 AM	ADDRESS	34.05074	-118.24176	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.Duplicate approved plan. Permit issued under 19041-10000-17677	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52233	12041-10000-22344	624 S GRAND AVE	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	PIN	34.04778206	-118.25563275	PLAN CHECK FOR REPLACEMENT OF UPS SYSTEMS AND EQUIPMENT ON 11TH FLOOR. OPTIONAL STANDY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52234	14041-10001-32803	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.01768	-118.42494	Changes to approved set - addition of sound stage effects lighting, minor revisions to general lighting.  (((PC FOR ENERGY. NEW HVAC AND CHANGING SOME LIGHTS FOR GYMNASUM. TOTAL AREA 10972 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52235	17041-10000-19748	12725 N ENCINITAS AVE	91342	7	219B141    66	2604035012	[Q]CM-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.30137	-118.47599	REPLACE  LIGHTING FIXTURES TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52236	14041-10000-14600	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	TITLE 24 AND EMERGENCY LIGHTING FOR SUITE 800 OF A HIGH  RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52237	14041-20000-35686	4421 N BELLINGHAM AVE	91604	2	165B165   304	2364003070	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.15105	-118.39882	PV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. ROOF MOUNTED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52238	18041-10000-15475	5528 N VINELAND AVE	91601	2	174B173  1153	2416001040	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.17092	-118.37008	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52239	13041-10000-26295	15451 W SUPERIOR ST	91343	7	201B145   461	2656004029	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.24654	-118.46932	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 225A MAIN; WORK DONE ON A STANDARD PLAN. 4 TOTAL STRINGS; COMBINER BOX WILL BE USED; SYSTEM SIZE IS 12KW DC WITH (48) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG PLUS V 11.4	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52240	11041-10000-27392	127 S SAN VICENTE BLVD Bulletin-134TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM	12/23/2011 12:00:00 AM		Permit Closed	02/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION Delta #134TI. Added (5) Branch ckts	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52241	14041-10000-04668	2757 S DUNLEER PL	90064	5	123B157   167	4255007006	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.03644	-118.42004	PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(17) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52242	16041-20000-14828	10870 W LA TUNA CANYON ROAD	91352	6	195B173    72	2408005033	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.23409	-118.36778	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 18424.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52243	14041-10001-13278	6555 W FOOTHILL BLVD	91042	7	201A203   106	2570019008	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Info Complete	08/20/2014 12:00:00 AM	ADDRESS	34.24594	-118.27468	(((8/19/2014 - Changes made to approved set.  Revised lighting layout, revised power layout, revised low voltage plan)))Master permit work description:  TI FOR EXISTING SMART AND FINAL. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52244	17041-10000-45914	1039 S LA CIENEGA BLVD	90035	5	132B173   489	4332030025	C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.05828	-118.37637	Full plan check for an assembly area with  new lighting and circuits.  Total load is less than 400A. Total area: 5,855 sq ft.B#17016-10000-35178	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52245	13041-10002-05741	380 WORLD WAY space T71	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	changes to approved set of plans: relocate 150kva xfrmr. changes to kitchen layout. revision 14. added exhaust fan. hood equipment. delta 9 under previous supplemental. original description: PROPOSED 6,092 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (III FORKS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52246	18041-10001-42888	2160 W ADAMS BLVD	90018	10	123B189   697	5052031021	R3-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.03248	-118.3142	PLAN CHECK ONLY, SUPPLEMENTAL FOR CHANGES TO APPROVED SET, ADDITION OF A WATER HEATER, A FCU, ALTERATION OF SOME OUTLETS, CHANGE TO PANEL LOAD, DELTA 5 CHANGES ONLYFULL PLAN CHECK FOR POWER AND ENERGY FOR OFFICE SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING  DISTRIBUTION SYSTEM. TOTAL EFFECTED AREA 17840 SQFT NEW CONNECTED LOAD OVER 497.24 AMPSBLD# 18016-10000-34802BLD# 18016-10000-28799	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52247	18041-10001-45023	6543 N TAMPA AVE	91335	3	180B117   586	2131009018	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.18959	-118.55376	Plan check for a lost set of plan. Permit is already pulled under original (master) set. (((PC FOR NEW ROOFTOP PV SYSTEM FOR (E) SFD. 3.8KW AC SYSTEM, (13) SOLAR MODULES, (1) 3.8KW SE3800H-US INVERTER, (13) P320 OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52248	13041-20000-06511	19865 W COVELLO ST PV-1	91306	3	186B113   267	2115016042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Expired	04/10/2015 12:00:00 AM	ADDRESS	34.20756	-118.56637	PV-1. Micro inverter standard plan. 3.67kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52249	11041-20000-22035	6333 W 3RD ST STALL #112	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM			PC Approved	10/14/2011 12:00:00 AM	ADDRESS	34.07157	-118.36014	PLAN CHECK T24 ENERGY/EMERGENCY FOR TENANT IMPROVEMENT TO EXISTING STARBUCK'S COFFEE SHOP LOCATED WITHIN LA FARMER'S MARKET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52250	14041-10000-14123	8736 N STANSBURY AVE	91402	6	195B153   906	2638009004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.22892	-118.44398	PV1 5.1KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(20)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52251	17041-10000-04619	20045 W RINALDI ST BLDG A5	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	ADDRESS	34.27564	-118.57092	PC FOR POWER AND ENERGY. NEW BUILDING A5  -SHELL ONLY  COMMERCIAL  - 1 STORY   SERVICE SIZE 800A 277/480 V, TOTAL AREA 6027 SQ FT.BUILDING APPLICATION 16010-10000-06139	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52252	17041-20000-17303	7919 N MASON AVE	91306	3	189B109   566	2108019006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Issued	06/01/2017 12:00:00 AM	ADDRESS	34.21426	-118.57993	Plan check for roof-mounted solar pv system on a SFD.10.4kW ungrounded system. (30) 295W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52253	16041-20000-04342	16300 W SHADOW MOUNTAIN DR	90272	11	132B121   218	4420039003	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.05841	-118.5395	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (34) modules, (1) inverter, and (1) combiner box. System is being interconnected with a 600-amp main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52254	18041-20000-34729	539 S MAPLETON DR	90024	5	138B157    57	4359013038	RE40-1	West Los Angeles	Westwood	Bel Air-Beverly Crest, Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.07466	-118.42924	pv1install roof  mounted pv system sized 18KW AC interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52255	16041-20000-34241	2631 W SOUTHWEST DR D	90043	8	105B189  1430	4007020017	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	33.9813	-118.3224	ti to an existing commercial space.  plan check for energy only.  total square footage 600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52256	14041-20001-04851	10989 N BARTEE AVE	91345	7	210B149  1062	2615020018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.2695	-118.45244	Fee for expedite fee only.****Roof mounted PV system with 4KWdc.****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52257	17041-10000-02381	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.05855	-118.23671	Plan check for Medium Voltage  supply Data equipment in exising building Service size: 1,200A  at 34.5kV 3 phase 3 W with 5 generators at 2500kW at 12.4kV	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52258	15041-20000-20763	21800 W OXNARD ST suite 950	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.17898	-118.60253	TI enery plan check  suite 950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52259	15041-10000-18477	1055 W WILSHIRE BLVD	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.05232	-118.2629	replacement of existing fire alarm panel.  applicant provided compatability sheet from manufacture to opearte with existing devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52260	14041-20000-29952	18936 W KESWICK ST	91335	3	186B121    49	2104013005	(T)(Q)R1-1, RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.21008	-118.54619	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MAIN SERVICE PANNEL(18) SUNPOWER E20-327 MODULES(1) SUNNY BOY SB6000 TRANSFORMER INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52261	19041-10000-43141	24111 W ALBERS ST	91367	3	171B089   111	2047013019	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Issued	11/25/2019 12:00:00 AM	ADDRESS	34.16758	-118.65072	$0 FEE DUE TO AB1414 [E-PLAN]CHANGES TO APPROVED SET. CHANGES TO THE ROOF TOP MODULES LAYOUT AND NUMBER OF MODULES PER STRING. NO CHANGES TO THE SYSTEM SIZE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52262	13041-10000-34007	6656 W FOOTHILL BLVD	91042	7	201A203    86	2564010012	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.24679	-118.27757	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 8100 SQ FT. REPLACING TOTAL OF 16 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52263	19041-20000-19399	1495 W OAK GROVE DR	90041	14	159A227    44	5480023019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.13147	-118.19843	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.64KW DC/3KW AC. SCOPE OF WORK INCLUDES (8) LG ELECTRONICS PV MODULES WITH A SOLIS 1P3K INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52264	12041-10000-23603	22716 W BALTAR ST	91304	3	189B097   320	2013030028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.21627	-118.62194	FOR A SFD, ROOF-MOUNTED 7.35KW PHOTOVOLTAIC SYSTEM USING MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52265	11041-20000-11547	18401 W VANOWEN ST	91335	3	183B125   942	2125011017	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM			PC Info Complete	07/21/2011 12:00:00 AM	ADDRESS	34.194	-118.53366	T.I.  Exisiting restaraunt doing a complete rhab.  Customer would like full plan check.  All citcuits in the panels are new.  The only thing to remain from the old restaurant are the service and the panels.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52266	19041-10000-21190	3916 W SUNSET BLVD	90029	13	145-5A203 391	5427007003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.09192	-118.28012	Energy plan check for a retail T.I. Scope includes new lighting and equipment with a total lighting area of 1458-SQ FT.(((EXTERIOR REFINISHING, INTERIOR REMODEL/BUILD OUT, NEW PARTITIONS, FIXTURES, FINISHES, STORE FRONT WORK, CHANGE OF USE - RESTAURANT TO RETAIL (1,558 SF))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52267	15041-10000-37205	2122 W 7TH ST	90057	1	132A203    83	5141018004	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.0567	-118.27768	Energy plan check for an new restaurant T.I.  permit fee is paid under 15041-10000-35978. Total area is 1158-SQ feet. Application is for plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52268	14041-10002-04305	345 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.05424	-118.25562	PC for lost set of plans. Originall permit under 14041-10000-04305. Original word description:Change of use for a portion of the first 4 floors of hotel to private school (grade 9-12) with basement and basement mezzanine use as auditorium. Classroom on the first floor and second floor dormitories on first floor mezzanine level and 3rd floor. (New light fixtures of 1371 are replaced on existing 277 v ckt. )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52269	14041-10003-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			07/31/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	DELTA 12 CHANGES TO THE APPROVED PLANS. LIGHTING AND POWER CHANGES IN THE SOCIAL CLUB & LEASING OFFICE.<<<<<PLANCHECK FOR POWER AND ENERGY FOR  A  NEW 472 Unit Type III  Apt. Building Over Type I Commerciasl Use & Garage Structure. TITLE 24 ENERGY SQFT NOT INCLUDED IN FEES. FEES ARE BASED APPLICANT.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52270	12041-20000-06236	6835 W FOOTHILL BLVD	91042	2	202-5A201 539	2568020027	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM	04/02/2012 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.24785	-118.28061	Service upgrade	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52271	17041-20000-28389	18801 W PASADERO DR	91356	3	165B121   330	2177020011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM			Reviewed by Supervisor	08/23/2017 12:00:00 AM	ADDRESS	34.14847	-118.54338	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (57) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52272	15041-20000-16829	6320 N TOPANGA CANYON BLVD G-1610	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT.  DRY BAR. 1658 SQFT. UNIT 1610	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52273	15041-20001-35413	3480 S 2ND AVE	90018	10	120B189  1158	5042003020	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.0232	-118.31876	FEES PER APPLICANT REQUEST.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.4 KWac.(28)MODULES-SUNPOWER 327W MODULES(2)INVERTER PVI-4.2OUTD-US (240V))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52274	13041-10000-10637	11411 W MISSISSIPPI AVE	90025	11	126B153  1038	4261035020		West Los Angeles				2677.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Issued	04/26/2013 12:00:00 AM	ADDRESS	34.03831	-118.44485	PV1 for 2 story house. 26 modules 1 inverter. [Solar Module: Innotech Solar 230 Module. Model#: 230W Module] [Inverter: Solar Edge. Model#: SE6000US]. Transformerless inverter. Total system size: 5.98KW system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52275	18041-20000-00601	12144 W LA MAIDA ST	91607	2	168B165   426	2356008003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.15841	-118.39803	PV1. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.16 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52276	15041-20000-02385	11903 W ART ST	91352	6	195B169    60	2631022017	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.23386	-118.39142	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.2kW. Ungrounded system.13  327W pv modules across two strings (6+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52277	18041-30001-12899	8620 S AIRPORT BLVD	90045	11	096B169   631	4125009020	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM			PC Approved	10/18/2018 12:00:00 AM	ADDRESS	33.95899	-118.38536	[[CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA 2 CHANGES. MINOR CHANGES TO LIGHTING.]]Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the ground floor. Total lighting area = 6,000 sq. ft.Note: Building application has been generated under 17016-30001-05804	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52278	17041-10001-04959	10400 N SEPULVEDA BLVD	91345	7	207B145   772	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM			PC Approved	06/16/2017 12:00:00 AM	ADDRESS	34.25939	-118.46706	PLAN CHECK FOR T-24 ONLY. SCOPE INCLUDES (DELTA 1 AND 2) CHANGES TO FIXTURES AND REVISIONS TO T-24 FORMS ORIGINAL 17041-10000-04959Plan check for Title 24 only T.I. existing sapce  retail. Total area: 2,705 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52279	19041-20000-46675	10400 N KEOKUK AVE	91311	12	204B113    77	2707022015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.25901	-118.5739	Plan check for PV roor mounted system, PV system size: 14.76KW DC, 11.4KW AC with 41 PV modules and 1 inverter(11.4KW) connected to existing 200A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52280	16041-10001-15170	12077 W VENTURA PL	91604	2	165B165  1214	2368002013	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.14493	-118.39507	07/14/16Changes to an approved set of plans. Changes include adding a switch bank for restaurant lights and replacing the occupancy sensors with time clock. No changes to the number of lighting fixtures. Note: Original application is under PCIS#16041-10000-15170(((((T24 - CHANGE OF USE TO A TAKE OUT RESTAURANT. SCOPE OF WORK INCLUDES NEW INDOOR AND OUTDOOR LIGHTING AND RECEPTECALS. TOTAL SQFT 650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52281	09041-20008-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to previously approved set of plans.  PLAN CHECK ONLY for ""DELTA 206""  on pages E305, E305B, E718.         <<<T. I. - new medical office bldg.(NEW HIGH RISE BUILDING, MEDICAL OFFICE, SHELL UNDER PCIS 08041-20000-22411)>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52282	15041-10000-32893	201 N FIGUEROA ST 12TH-FLOOR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	T24, TI TO THE 12TH FLOOR IN AN (E) HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. ONE NEW PANEL CONNECTED LOAD < 400 AMPS. PC FOR ENERGY ONLY TOTAL SQ. FT. 1501.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52283	15041-10000-07065	200 WORLD WAY # 283	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR ENERGY. INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM  ROW. TOTAL AREA  34.39SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52284	19041-20000-38588	117 N ARDEN BLVD	90004	4	138B189  1417	5515011018	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.07366	-118.32623	PV1. INSTALL 12 KW DC / 10.91 KW AC PV SYSTEM WITH (30) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52285	13041-20000-30768	7192 W ESTEPA DR PV1	91042	7	198B197   121	2562021007	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.24227	-118.28902	"New 18.639kw Photovoltaic System on the roof of an existing single family dwelling.  System is UNGROUNDED. ""$0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52286	14041-20000-29072	20548 W GERMAIN ST	91311	12	207B109   565	2707012024	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.26158	-118.58154	PV1Using standard plan. Install roof-mounted solar array on SFD. System size: 7.2kW. Two 3.6kW inverters with 2 strings each. 42 255W pv modules. Ungrounded system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52287	17041-10000-34065	427 W 5TH ST	90013	14	129A211    12	5149028017	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	08/18/2020 12:00:00 AM	ADDRESS	34.04937	-118.25245	PC FOR FA IN A NEW HIGH RISE BUILDING.SCOPE INCULDES 1932 DEVICES AND 13 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52288	17041-20000-37151	8016 N 3RD ST	90048	3	138B177   762	5511028027	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	PIN	34.07166893	-118.36446535	new fire alarm control panel with 33 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52289	18041-20001-44035	1476 E 92ND ST	90002	15	094-5A211  45	6048001017	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	PIN	33.95297022	-118.24797128	expeditepv1install roof mounted pv system sized 5KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52290	15041-20001-20270	7120 N INDEPENDENCE AVE	91303	3	183B109   187	2112031017	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	34.19989	-118.59048	Revisions to approved plan.  Design set submitted to reflect as-built conditions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52291	16041-20001-37078	12203 W MOORPARK ST	91604	2	165B165   349	2364003046	[Q]R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			12/11/2018 12:00:00 AM			PC Approved	12/11/2018 12:00:00 AM	ADDRESS	34.15056	-118.39892	12/11/2018changes to an approved set of plans.  changes to install bug eye and battery backup EM fixtures.this is plan check only.  ((((Plan check for power and energy. Project site is a new 3-story, 16-unit apartment building. Work includes a new 1,200-amp service and associated distribution equipment. Total lighting area is 15,410 sq. ft.Note: Building application has been generated under 16010-30000-01740))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52292	13041-20000-26116	225 N CAROLWOOD DR	90077	5	141B157   408	4358005027	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.08188	-118.42612	PV1 CENTRAL INVERTER. TOTAL 11.42KWAC SYSTEM. 36 MODULES AND 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52293	19041-20000-28310	5050 N NAGLE AVE pv1	91423	4	171B157   847	2359010021	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.16281	-118.42347	pv1install roof mounted pv system sized 9.41KW AC, 10.44KW DC  with 29 PV Moduels and 1 inverter(10KW) interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52294	14041-20000-30988	7311 N DARNOCH WAY	91307	12	186B089   622	2027020021	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.20347	-118.64461	pv1central string inverter standard plan system sized 8.6kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52295	12041-10000-17141	7966 W BEVERLY BLVD	90048	5	138B177   463	5511002025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM			PC Approved	07/23/2012 12:00:00 AM	ADDRESS	34.07593	-118.36326	Plan check for energy only. Outdoor 2273 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52296	18041-20000-10452	3349 N CAHUENGA BLVD WEST #6	90068	4	159B181   496	2425026010	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.13103	-118.35142	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 854 sq. ft.Note: Building application has been generated under 18016-20000-08035	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52297	14041-10000-06674	3207 S SAN PEDRO ST	90011	9	118-5A207 425	5120020017	[Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.01676	-118.26466	PLANCHECK FOR POWER AND ENERGY FOR NEW AUTOMATIC CARWASH.  ( PLANS INCOMPLETE, SUBMITTED UPON APPLICANTS REQUEST. APPLICANT WAS INFORMED ABOUT ADDITIONAL FEES)BUILDIGN P# 14010-10000-00819 : NEW AUTOMATIC CAR WASH WITH 11 VACUUM STATIONS.Electricla permiotb is under the supplementa l (14041-10001-06674) due to cahnge in voltage,  This application is plan check only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52298	13041-20000-18899	17300 W PACIFIC COAST HWY	90272	11	126B117   675	4416009901	OS-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Info Complete	07/26/2013 12:00:00 AM	ADDRESS	34.03835	-118.55615	RENOVATION OF AREA INSIDE EXISTING RESTAURANT. ASSEMBLY OCCUPANCY. NEW BAR. NEW LIGHTING AND CIRCUITS. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52299	16041-20000-42778	7412 N BALBOA BLVD	91406	6	186B133   704	2226029004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.20514	-118.50093	pv1install roof mounted pv system sized 11kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52300	11041-10000-17403	1888 CENTURY PARK EAST	90067										Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM				TI TO AN EXISTING BANK.  PLAN CHECK IS FOR ENERGY WITH EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52301	16041-10000-23582	6915 S LA TIJERA BLVD	90045	11	102B173   146	4103003016	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	33.97595	-118.37359	PC for energy only to store #8075 in commercial building. Adding new lighting and power. Total sqft = 3350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52302	15041-20000-11421	11310 W SHERMAN WAY	91605	2	183B173   112	2319001006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM			PC Approved	04/16/2015 12:00:00 AM	PIN	34.19989971	-118.37702755	Title 24 plan check only.  Total area = 3,980 sq. ft.Interior renovation and addition to industrial space.  Area of work does not include any hazardous locations and is to be used 24 hours/day per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52303	16041-20000-41652	10701 W ARTRUDE ST	91040	7	201B177   256	2542020025	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.24725	-118.36259	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (46) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52304	19041-10000-31775	1798 W WASHINGTON BLVD	90007	1	126B197   814	5075033009	[Q]CM-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	10/10/2020 12:00:00 AM	ADDRESS	34.03978	-118.29713	PC ENERGY ONLY FOR CHANGE OF USE PORTION OF EXISTING MANUFACTURING BUILDING TO COFFEE SHOP. AREA SCOPE 1446. BUILDING PERMIT #: 18016-30000-39318	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52305	17041-20000-17242	611 S GAYLEY AVE	90024	5	135B149   217	4363006021	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			05/23/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.06777	-118.44876	Plan check for power and energy. New 22-unit, 4-story student dormitory over 2-levels of parking. 800A service. T24 area: indoor - 20,069sqft; outdoor - 4,719sqft.Building permit filed under 15010-10000-01460.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52306	16041-10000-41756	818 W 7TH ST	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.04895	-118.25943	T-24, PC FOR ENERGY ONLY LOBBY RENOVATION AND ADDITION OF NEW SEATING PADS ON THE 2ND FLOOR AND DECORATIVE FIXTURE HANGING FROM 3RD FLOOR.SCOPE INCLUDES NEW LIGHTS FOR LOBBY AREA. TOTAL AFFECTED AREA IS 9744 SQ. FT. B#16016-30000-24184	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52307	15041-20000-03932	2029 S CENTURY PARK EAST MEZZANINE	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Expired	04/13/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI TO AN EXISTING OFFICE BUILDING HIGH RISE.  ADDING NEW LIGHTING AND NEW CONTROLS.  USING EXISTING CIRCUITS AND PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2260.  SCOPE OF WORK TO BE PERFORMED IN MEZZANINE SUITE 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52308	19041-10000-31812	7000 W MANCHESTER AVE	90045	11	096B161   691	4122022927	OS-1XL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.95957	-118.41378	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52309	16041-20001-05736	20930 W COMMUNITY ST	91304	3	192B109   921	2779006195	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.22197	-118.58964	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 3 kWac, for a total system size of 6.8 kWac. Addition consists of (1) inverter, (10) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52310	18041-10000-34165	16190 W MULHOLLAND DR	90049	11	159B137   491	4490003005	RE40-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.12959	-118.48538	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52311	14041-10000-30933	3216 S BROADWAY	90007	9	118-5A205  61	5122006025	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	34.02016	-118.2729	Energy plan check for outdoor lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52312	17041-10001-21623	421 E 116TH ST	90061	15	084B205  1548	6083006029	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2017 12:00:00 AM			Hold Released	09/15/2017 12:00:00 AM	ADDRESS	33.92928	-118.26569	EXPIDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV SYSTEM WITH STORAGE BATTERY. PV SYSTEM SIZE 3.0 KW ACTOTAL OF 8 PV MODULES WITH OPTIMIZERSBATTERY IS TESLA POWERWALL 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52313	12041-10000-23498	4238 N COLBATH AVE	91423	5	165B153   737	2266017013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.14721	-118.43599	Plan check new roof mounted 10.5KW photovoltaic sytem using Aurora transformerless inverters. Original permit under #12041-2000-21538. Additional permit for inverter and subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52314	15041-20000-42898	16136 W ROYAL MOUNT DR	91436	5	165B141   374	2285016013	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.14686	-118.48481	PV1.  Install 8.99 kW roof-mounted, utility-interactive PV system.  (29) Canadian Solar 310 modules with (1) SolarEdge SE7600A-US transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52315	17041-20001-22659	11114 N BORDEN AVE	91331	7	210B165   379	2532030011	RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			PC Approved	07/10/2017 12:00:00 AM	ADDRESS	34.2719	-118.4038	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52316	15041-20000-12428	8034 N LLOYD AVE	91605	2	189B181   140	2403024011	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.21701	-118.42057	Plan check for PV roof mounted 5kWac system with 25 modules and 1 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52317	18041-10001-01266	1508 N LACHMAN LANE	90272	11	135B121    50	4420035004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM			Reviewed by Supervisor	01/24/2018 12:00:00 AM	ADDRESS	34.06302	-118.54979	expedite per applicant requestPC FOR NEW ROOFTOP SOLAR SYSTEM CONSIST OF 43 MODULES (SOLAR CITY SC325) AND 2 INVERTERS( DELTA SOLIVIA 6.6TL @ 6.6KW & DELTA SOLIVIA 5.2TL @ 5.2KW ) .  SYSTEM SIZE IS 13.975KWdc and 11.8KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52318	18041-20000-48901	5751 W VALLEY OAK DR	90068	4	151-5A191 155	5587013038	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.10984	-118.31483	INSTALLING 2 NEW TESLA 27KWH ENERGY STORAGE BATTERY ON EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52319	14041-20000-34426	12100 W WILSHIRE BLVD	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.0438	-118.46755	TI TO AN EXISITNG HIGH RISE COMMERCIAL BUILDING.  ADDING LIGHTING TO VARIOUS OFFICES ON THE 8TH FLOOR SUITE 800.  USING EXISTING PANELS WITH WITH NEW CIRCUITS. TOTAL SQUARE FOOTAGE 4,730.  PLAN CHECK FOR ENERGY AND EMERGENCY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52320	19041-10000-40760	8485 N PENFIELD AVE	91306	3	192B113   232	2782010127	(T)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.22438	-118.569	PLAN CHECK FOR ROOF MOUNTED 3.12KVA PV1 SYSTEM CONSISTING OF 13 MODULES USING EMPHASE IQ7-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52321	16041-20001-08618	337 W 45TH ST	90037	9	112-5A203 110	5110003016	RD2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Apartment			03/11/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.00299	-118.2796	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a single unit of a 3-unit property.System size: 3.6kW. Ungrounded system. (13) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52322	18041-10000-41287	624 S GRAND AVE 1610&1500	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	PLANCHECK FOR POWER AND ENERGY FOR DATA CENTER. INSTALLING MEDIUM VOLTAGE SWITGEAR AND LIGHTING IN SUITE 1610 AND SUITE 1500. NO CONNECTEDLOAD UNDER THIS SOW, LOAD ON DISTRIBUTION PANEL AND FLOOR PLANS ARE FOR REFERENCE ONLY (FOR FUTURE INSTALLATION). TOTAL AREA: 13,745 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52323	19041-10001-44941	20209 W RINALDI ST	91326	12	210B113   291	2701100009	A1-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM			PC Approved	02/12/2020 12:00:00 AM	ADDRESS	34.27509	-118.57388	Plan check for a PV2 158 KW AC / 191 KW DC roofmounted system. Scope include 440-module, (3) inverter interconnecting throgh the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52324	12041-10000-07779	7301 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM			PC Approved	05/15/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	Change to outdoor canopy lighting at Tom Bradly International Terminal.  Load is 30A per applicant.   PLAN CHECK ONLY for Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52325	17041-10000-13463	10348 N SEPULVEDA BLVD	91345	7	204B145   168	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Issued	04/25/2017 12:00:00 AM	ADDRESS	34.25886	-118.46706	PC FOR FA SYSTEM IN BANK. NEW PANEL AND DEVICES. USING WIRELESS TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52326	14041-20001-13607	10158 N BALBOA BLVD	91343	12	204B133   309	2685002026	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM			Corrections Issued	08/22/2014 12:00:00 AM	PIN	34.2556262	-118.50116066	PLAN CHECK FOR RESTAMP LOST SET OF PLANS. PLAN CHECK TO VERIFY CALCULATIONS ONLY. RESTAMP T24 CALCS. REMODELING OF A SALVATION ARMY STOREPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52327	11041-10002-25912	3023 S WESTERN AVE 1-60	90018	10	120B193   522	5053006903	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Apartment			07/09/2012 12:00:00 AM			PC Info Complete	07/09/2012 12:00:00 AM	ADDRESS	34.02667	-118.30906	"Delta 6 Changes only to add one 20A circuit for a ""grey water"" pump to a previously approved set of drawings for new apartments in a methane zone.                                                     <<<CONSTRUCT NEW 4-STORY, 60-UNIT, TYPE VA, AFFORDABLE HOUSING BLDG IN A METHANE ZONE W/ FIRST LEVEL FOR PKG AND RESIDENTIAL/COMMON AREA. NFPA-13 automatic fire sprinkler sytem for story and allowable floor area increase. Variance is filed to separate the FA PLANS.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52328	16041-10001-12080	5735 W ADAMS BLVD	90016	10	123B173   824	5048005039	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	34.03262	-118.36814	EXPEDITE PER APPLICANT REQUEST. ((((PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 17.00KWac INTERCONNECTED WITH MSP (SINGLE PHASE SYSTEM).(68) SOLARWORLD 285 MODULES(68) ENPHASE 250 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52329	13041-10003-19659	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			04/06/2015 12:00:00 AM			PC Approved	04/06/2015 12:00:00 AM	ADDRESS	34.09918	-118.32644	REVISED SINGLE LINE NOTE 14 TO INDICATE THE USE OF LISTED 2-HOUR FIRE RESITIVE MINERAL CABLE BY PENTAR(((((POWER AND ENERGY PLAN CHECK 287 UNIT APARTMENT BUILDING WITH FUTURE RETAIL SPACES. 7 STORY  LOW RISE BUILDING. VARIANCE TO SEPERATE FIRE ALARM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52330	14041-10001-28477	1043 S KINGSLEY DR	90006	10	129B193   528	5080025009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	01/12/2015 12:00:00 AM	ADDRESS	34.05133	-118.30329	PV2, 21.1 Kw roof-mounted system including (4)Delta Solivia 5.2TL  inverters , and (88) LDK 280p-24 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52331	13041-10000-34163	726 E ANAHEIM ST	90744	15	030B209   199	7424011042	[Q]M2-1VL-O, [Q]MR2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	33.78028	-118.25354	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 19095 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52332	12041-20000-23112	14718 W WYANDOTTE ST	91405	6	186B149   780	2218022004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.2029	-118.45371	New 13.47kw rooftop mounted PV system for an existing single family residence.  System is transformerless and ungrounded.  Additional circuit is for the monitoring system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52333	16041-10000-28907	1801 S CENTURY PARK EAST 1600/1700	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.06201	-118.41537	Plan check for T-24 only.  TI on the  16th and 17 floors to  plans.   Scope of work covers offices, small corridor area, pantry, conf. room.  Install new lights, receptacle, and 225A with newly connected load < 400A.  Total effected area: 2,240 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52334	17041-20000-09088	726 W 167TH ST	90247	15	066B197    60	6121008008	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	33.87976	-118.2879	pv1install roof mounted pv system sized 1kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52335	19041-20000-26818	704 E 62ND ST	90001	9	105B205   809	6007010003	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM			PC Info Complete	01/31/2020 12:00:00 AM	ADDRESS	33.98311	-118.26273	Distribution, power, and lighting for (E) commercial building change of use.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52336	16041-10000-34067	20181 W ADELE DR	91364	3	168B113   319	2175028025	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.15617	-118.57311	New PV1 rooftop solar system, 7.6 kW AC. Using (22) AC Modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52337	17041-10000-31372	9939 N BABBITT AVE	91325	12	201B133    19	2694013028	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.25157	-118.5102	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 54 AC MODULES(SUNPOWER SPR-X21-345-C-AC). SYSTEM SIZE 17.28KVA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52338	16041-10002-34648	10250 W SANTA MONICA BLVD #1570	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"**Changes to approved set: Changes due to architectural design: Update location of EF1, add track lights, update T24 forms. Changes noted under delta-3.  Permit is covered under master plan 16041-10000-34648.*Changes to approved set: Change of use from restroom to storage. Others remained the same, changes noted under delta-2.  Permit shall be issued under master plan 16041-10000-34648.<<Full Plan check for a first time tenant space at westfield mall ""Zadig"". Adding a new panel and a tranformer under existing service. New lighting and power. Total sqft = 2243.  43A to MS-ELA42"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52339	19041-20000-00589	9432 N FARRALONE AVE pv1	91311	12	198B101   108	2727019018	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.2418	-118.61024	pv1install roof mounted pv system sized 13.5KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52340	16041-10001-09376	2626 N ZORADA DR	90046	4	153B177    25	5569020014	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.11904	-118.36226	*Zero dollarPermit fee due per CA Senate Bill 1222*7/22/16: Revision to approved set of plan: revise electrical equipment layout (relocate AC disconnect) and add LADWP performance meter. All other remain the same.<<PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (58) SUNPOWER MODULES AND (2) SMA SUNNYBOY INVERTERS AT 7KW. TOTAL SYSTEM SIZE 14KW.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52341	16041-20000-10186	4675 N GALENDO ST	91364	3	166-5A105  98	2171024063	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.15144	-118.60088	"""$0 permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.76 KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52342	19041-10000-18551	3501 W JEFFERSON BLVD	90018	10	120B185  1545	5051029***	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	ADDRESS	34.02572	-118.33394	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52343	16041-10000-23611	1150 S OLIVE ST 2350	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	Title 24 plan check only.  Total area = 5,585 sq. ft..T.I. ON THE 23RD FLOOR OF AN EXISTING COMMERCIAL HIGHRISE BUILDING.  NEW LIGHTING AND RECEPTACLES.  ALL PANELS TO REMAIN EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52344	18041-10000-39721	6500 W HOLLYWOOD BLVD	90028	13	148-5A187 179	5547016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	05/11/2020 12:00:00 AM		Permit Finaled	01/11/2021 12:00:00 AM	ADDRESS	34.10143	-118.33126	NEW 7 ELEVEN CONVENIENCE STORE. PLAN CHECK FOR POWER & ENRGY. 2220 SQR FT.BUILDING PERMIT: 18016-10000-26224	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52345	17041-20003-36915	742 N ORANGE DR	90038	5	141B181   378	5524014004	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.08467	-118.34147	Changes to approved set.  Reduction of feeder OCP rating to 125A; wire detail changes. Approval for hand-drawn clouded portions only. (((PC FOR CHANGES TO APPROVED SET.SCOPE INCLUDES TWO ADDITINOAL  ESS'S (TESLA POWERWALL 2 )WITH NEW PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52346	12041-20000-00992	444 S FLOWER ST 32nd floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Info Complete	01/17/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	T.I. to existing high rise building on 32 floor in restrooms.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52347	18041-10000-38507	725 S FIGUEROA ST # 1860	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	ALTERATIONS IN EXISITNG OFFICE SPACEPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52348	13041-10000-35873	11065 W SUNSET BLVD	90049	5	138B149   122	4366002014	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2013 12:00:00 AM			Reviewed by Supervisor	05/01/2014 12:00:00 AM	ADDRESS	34.07469	-118.45729	"NEW ADDITION 9,647 SQ FT 2-STORY HOUSE TO EXISTING 2-STORY RESIDENCE 9,868 SQ FT. UPGRADING SERVICE TO 800A, 120/204V, 1PH, 3W. NEW DISTRIBUTION BOARDS ""MSA-1 & MSA-2"" 800A BUS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52349	14041-10000-17258	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.06488	-118.47066	Title 24 plan check only.  Total area = 3,310 sq. ft.Classroom remodel of existing school, including new lighting and relocated recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52350	16041-10000-34835	3866 S CRENSHAW BLVD	90008	10	117B185   878	5033003002	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	ADDRESS	34.01531	-118.33473	CHANGE OF USE FROM RETAIL TO RESTAURANT 1876SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52351	16041-10000-00690	605 N FLINT AVE	90744	15	030B209   448	7424024006	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	33.77804	-118.24941	PC for energy only to a commercial building (fish plant).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52352	15041-10000-01563	12121 W WILSHIRE BLVD #1103	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM			PC Approved	01/26/2015 12:00:00 AM	PIN	34.04391963	-118.46825257	Plan check for T-24 only. T.I. for office. Total area: 3140SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52353	18041-20000-08550	3019 E ASBURY ST	90065	1	147A217    68	5454031025	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Issued	03/08/2018 12:00:00 AM	ADDRESS	34.09865	-118.23001	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.85 KW  + INSTALLATION OF ENERGY STORAGE 13.5 KWH	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52354	15041-10000-01895	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.21328	-118.45279	Plan check for T24 only. Total area: 8490SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52355	12041-10000-14483	23235 W ARMINTA ST	91304	3	189B093   472	2020022033	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.21304	-118.63329	"Plan check for PV System. 10.20kW DC using transformerless inverters.  Plan check is only for Photovoltaic System.  Permit fees, including Service Upgrade, are under ""INPSECTION""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52356	17041-10000-29841	11025 S FIGUEROA ST	90061	8	088-5A201 351	6075022014	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	33.93495	-118.28278	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52357	15041-20000-41077	10457 N VARIEL AVE	91311	12	207B105   630	2706020021	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.26061	-118.59314	PV1 roof mounted solar installation. 12kW AC (Panel derate)(40) SPR-327NE-WHT-D(2) PVI-6000-OUTD-S	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52358	14041-20000-28383	15766 W COBALT ST	91342	7	222B141   255	2604014076	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.30269	-118.47413	INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.4KW INTERCONNECTED WITH MSP.(28) SUN POWER SPRE20 MODULES(2) POWER ONE PVI-4.2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52359	13041-20000-10034	751 N FAIRFAX AVE 1-12 PV	90046	5	141B177  1448	5527012***	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.08526	-118.36177	PV. Plan check for central inverters on mixed-use building (retail + appartment). 48 panels, one 11.5kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52360	16041-10000-39510	10250 W SANTA MONICA BLVD # 1810	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Steve Madden"" Ste. 1810.  Install new Xrfmr, and  panels < 200A, total area 1500 sq.ft*** New load is 37A to MS-ELA33"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52361	11041-10000-00777	175 S FAIRFAX AVE	90048	5	138B177   750	5511026004	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	NEW 1 STORY COMMERCIAL BUILDING. PLAN CHECK IS FOR POWER & ENERGY. CORE & SHELL ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52362	17041-10000-32137	3860 S GRAND VIEW BLVD	90066	11	111B157    88	4235025036	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	04/15/2022 12:00:00 AM	ADDRESS	34.0035	-118.42997	TITLE 24 PLAN CHECK FOR REPLACEMENT OF EXISTING (14)HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA  75750 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52363	13041-10000-09305	19500 W PLUMMER ST G2	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	Buidling G improvement.  Add new branch circuits and  new two 150KVA transformer (Class 155).   Relocate 75KVA transformer in the electrical room.  Install new general/emergency lighting for tenant G-2.  All panels are existing.    Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52364	17041-10000-07299	835 W JEFFERSON BLVD STE 1740	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	"FULL PC FOR RESTAURANT ""RANCE'S PIZZA"", FIRST TIME OCCUPANCY IN BUILDING UNIT 7J, TOTAL AREA: 1,621 SQ. FT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52365	17041-10001-32414	415 S OCCIDENTAL BLVD 1-15	90057	1	135A201    18	5155010013	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Apartment			09/11/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.06581	-118.28359	expedite feeesPC FOR PV SYSTEM ON APARTMENT BUILDING. TOTAL SIZE 15.4KW AC/ 20.4KW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52366	13041-10002-22485	11040 W PICO BLVD	90064	5	126B153  1136	4256008014	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			PC Info Complete	11/05/2014 12:00:00 AM	ADDRESS	34.03753	-118.43352	[[[10/7/14 CHANGES TO APPROVED SET. DELTA  A CHANGES ONLY. PERMIT HAS BEEN PULLED UNDER 13041-10001-22485, ORIGINAL HAS BEEN INCLUDED]]]]][][CHANGES MADE TO FIRST SUBMITTAL PLANS; CHANGES IS TO COVER THE FOLLOWING: 1)TITLE-24, 2) DELTA-A and DELTA C CHANGES TO THE MASTER PLAN, ][][][PC FOR POWER AND ENERGY. TI TO (E) RETAIL.  99c STORE FULL TENANT IMPROVEMENT. 1000A service. previously a furniture store. not a methane zone. WITH PARKING LOT RE-STRIPING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52367	15041-10000-25578	1726 S HOOPER AVE	90021	14	120A213   278	5129009023	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM			PC Info Complete	08/13/2015 12:00:00 AM	ADDRESS	34.02255	-118.24535	ALTERATION TO EXISTING FACTORY SPACE. PC FOR T-24. per Francise	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52368	12041-20000-30691	61 N BEVERLY PARK	90210	5	156B161    80	4386008009	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2012 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Expired	02/03/2015 12:00:00 AM	ADDRESS	34.12091	-118.41587	Upgrade an existing generator on a 1200 amp service single family home to 438kva.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52369	11041-10000-02847	930 S HILGARD AVE	90024	5	135B153   541	4360006025	[Q]R5-1L-O	West Los Angeles	Westwood	Westwood		2652.00	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.06306	-118.44116	Replacing the mechanical units & generator for an existing hotel. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52370	09041-10002-03128	6215 W SUNSET BLVD	90028	13	147A189    23	5546026019	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/25/2010 12:00:00 AM			PC Approved	01/25/2010 12:00:00 AM	ADDRESS	34.09817	-118.3244	Revise single line diagram to add transformer secondary protection and relocate an exhaust fan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52371	19041-20000-02900	22122 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			01/24/2019 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.1863	-118.60916	Replacement of (E) pole lights with new in apartment complex common area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52372	15041-10000-03554	904 E 116TH ST	90059	15	084B209   143	6084030023	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	33.92905	-118.25831	Plan check for PV1 roof mounted system 8.925kW with 35 modules (yingli YL255p-29b) and (1) PVI-5000-OUTD-US-Z-A and (1) PVI-3.0-OUTD-US-Z-A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52373	14041-10000-17631	1391 W SUNSET BLVD	90026	1	138A211    26	5406012038	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.07391	-118.25153	INTERIOR TENANT IMPROVEMENT, CHANGE OF USE FROM (E) RETAIL TO RESTAURANT (108 OCCUPANT LOAD).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52374	12041-10001-14645	2749 W 15TH ST	90006	10	129B193  1514	5075011023	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM			PC Approved	08/24/2012 12:00:00 AM	ADDRESS	34.04555	-118.30175	Modification to previously approved set of plans to change some devices from ceiling mount to wall mount.  Plan Check Only.                  <<<<New fire alarm system.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52375	15041-20000-26323	2000 S AVENUE OF THE STARS MEZANINE-SUITE 500	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	34.05868	-118.41546	TI TO AN EXISTING OFFICE BUILDING HIGH RISE.  ADDING NEW LIGHTING AND NEW CONTROLS.  USING EXISTING CIRCUITS AND PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2260.  SCOPE OF WORK TO BE PERFORMED IN MEZZANINE SUITE 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52376	16041-20001-40610	13758 1/2 W ROSCOE BLVD	91402	6	192B153   773	2213016003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.22139	-118.43316	01/19/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for energy only. TI to commercial space - donut shop. New lighting (incl. emergency). 780sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52377	15041-10000-39142	2010 W WILSHIRE BLVD	90057	1	132A203    31	5141002019	C4-2	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Public Safety Only			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.05745	-118.27519	REPLACING FACP  WHICH IS AN UPGRADE BY THE SAME MANUFACTURER;EXISTING FA DEVICES ARE BY SAME MANUFACTURER ALSO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52378	18041-20000-12509	8408 W HILLSIDE AVE	90069	4	148-5A173 480	5558028027	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.09935	-118.3728	permit fees $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 3.9kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52379	12041-20000-07282	14117 W HUBBARD ST #1	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.29849	-118.44081	Ti first time tenant. Plan check for power, energy, and emergency lighting. 1422 conditioned floor area. single story commercial.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52380	13041-10000-28006	1834 S WILTON PL	90019	10	126B189   770	5073018007	[Q]R3-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Apartment			10/08/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Expired	11/05/2015 12:00:00 AM	ADDRESS	34.04066	-118.31428	PV2 2.5KWdc. 240V. negative GND. NONstd. 1story. Roofmount. [(1) inverters: {SMA SB2000HF}]. [(10)modules: {Hanwha {HSL60P-PB-4-250QB}}]     part of a quadplex. changes made on plans: bollards in front of equipment, equipment fully rated for 22KAIC, and #8 from inverter to sub panel - mt 10/11/2013)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52381	18041-10000-09060	5722 W JEFFERSON BLVD	90016	10	120B173   311	5047018002	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.02588	-118.36994	PC FOR TI INSIDE AN EXISTING FACILITY. T-24 ONLY. SCOPE INCLUDE NEW LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 5650 SQ.FTB# 17016-10000-33624	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52382	17041-10001-36884	742 S CLOVERDALE AVE	90036	4	132B181   166	5089002015	[Q]R4-1-HPOZ	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.06096	-118.34655	Supplemental for expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52383	12041-20000-07112	19361 W SATICOY ST	91335	3	186B117    45	2116014020	QC2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.20851	-118.55515	CHG OF USE TO DENTAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52384	17041-20001-32215	6447 N CLEON AVE	91606	2	180B173   741	2414030021	QRD4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.18804	-118.36826	expeditepv1install roof mounted pv system sized 6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52385	16041-10000-42382	355 S GRAND AVE # 1650	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.05191	-118.2525	PC FOR ENERGY ONLY, TI NO CHANGE OF USE OFFICE, HIGH RISE BUILDING . TOTAL AREA 8823 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52386	11041-20000-15918	15350 W SHERMAN WAY	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			Corrections Issued	07/29/2011 12:00:00 AM	ADDRESS	34.20099	-118.46808	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52387	18041-20000-36257	5555 W MELROSE AVE TELECOM-GENERATOR	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	01/29/2024 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for power only replace new generator, distribution equipment and installed UPS equipment; relocate some load to UPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52388	19041-20002-33091	6514 N ALDEA AVE	91406	6	180B133   345	2230022014	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Issued	10/08/2019 12:00:00 AM	ADDRESS	34.18905	-118.5078	$0 plan check fee due to SB1222 and AB1414Supplemental plan check, changes to approved set, clouded changes only. Removal of a 13.5 KWH battery. minor change to site plan, single line, and elevations. Reduction of 12.285 KW PV/40.5 KWH energy storage system to 12.285 KW PV/27 KWH energy storage system.original PV and ESS permit under 19041-20000-33091	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52389	13041-20002-16324	11929 W COURTLEIGH DR	90066	11	111B157  1103	4233018006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			02/26/2015 12:00:00 AM			PC Approved	02/26/2015 12:00:00 AM	ADDRESS	33.99687	-118.41943	[[[2/26/15 CHANGES TO APPROVED SET. DELTA 3 CHANGES ONLY. UPDATING PLANS TO REFLECT INSTALLATION PER INSPECTORS REQUEST AND MINOR LIGHTING CHANGES]]]revisions to permitted set of plans:residential distribution board is rated 1phase 3W INSTEAD OF 3PH 4W;SUMP PUMPS AND BOILER EQUIPMENT ARE REMOVED AND EV CHARGERS UPSIZED; ALL CHANGES ARE CLOUDED; SERVICE LOAD CALCULATIONS WERE REVISED ACCORDINGLY(((((((((New 4-story 22-unit apartment building.  Power and energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52390	15041-30000-37299	17400 W BURBANK BLVD	91316	5	174B129   863	2254036026	R3-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.17211	-118.51191	$0 PERMIT FEE PER SENATE BILL 1222.Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 30.8 kWac.  System consists of 4 7.7 kWac inverters with 27 modules each.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52391	19041-30000-31940	1267 S WESTWOOD BLVD	90024	5	132B153   588	4324004016	C4-1VL-POD	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.05736	-118.44323	energy plan check  only for new lighting in area. Total area of scope 842sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52392	19041-20002-01450	665 E BROOKS AVE	90291	11	111B145  1720	4239008***	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	33.99668	-118.46674	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CLOUDED CHANGE ONLY, CHANGE TO SUB PANEL B BUS RATING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52393	16041-10000-16057	11500 W PICO BLVD	90064	11	123B153   492	4260034038	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.03326	-118.44223	T-24, CHANGE OF USE FROM OFFICE & RESTAURANT TO CHARTER SCHOOL - ELEMENTARY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3620	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52394	14041-20000-23615	1221 W 30TH ST	90007	9	120B197   251	5055010027	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.02754	-118.2897	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.STANDARD PLAN CENTRAL TRANSFORMERLESS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52395	11041-10000-26778	1400 S GRAND AVE #801, 804	90015	9	124-5A207  58	5134020023	C2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.03697	-118.26528	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING  SUITE # 801 & 804 OF EXISTING  MEDICAL OFFICE. NO WORK IN PATIENT CARE AREA. PERMIT TO REPLACE EXISTING AND ADD NEW LIGHT FIXTURES, ADD EXIT SIGNS, ADD RECEPTACLES ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52396	19041-20000-44889	22230 W SCHOENBORN ST	91304	12	192B101   586	2010020031	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.22025	-118.61146	PV1. INSTALL 9.72 KW DC PV SYSTEM WITH (27) MODULES/OPTIMIZERS AND (1) INVERTER (SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52397	17041-10000-31436	1801 S CENTURY PARK EAST	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.06201	-118.41537	PC for T24 only for TI to lobby, parking, outdoor and mezanine area in 23 story high rise building. Installing new lights, receptacles and circuits. Total area of 6,677sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52398	14041-20000-21914	10753 W ARMINTA ST	91352	2	189B177   402	2409007020	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.21384	-118.36538	FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 11.4kW.(1) SolarEdge SE11400A-US transformerless inverter(54) Solar World Sunmodule SW250 Poly pv modules(54) SolarEdge P300 power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52399	15041-10001-38812	121 W 115TH ST	90061	15	087A203   368	6087001018	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	33.93021	-118.27466	Supplemental PC, change orientation of the inverter, adding 125A load center.<<<PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) KYOCERA 2656 MODULES(1) ABB PVI-3.0 INVERTER>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52400	14041-10000-08358	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	33.94248	-118.40461	PLANCHECK FOR T24 ENERGY. SIGN LIGHTING FOR FARMERS MARKET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52401	13041-10000-18275	8436 N FABLE AVE	91304	12	192B093   184	2005018018	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.22172	-118.64176	PV1  XFRMless. 1 STORY HOUSE. nonSTD. 2 INVERTERS: SOLAREDGE SE5000A-US,  SE3800A-US. MODULES: 39 TRINA TSM-245PC05/PA05.18 . POWER OPTIMIZERS. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 9.555 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52402	10041-10000-13610	12403 W WASHINGTON PL	90066	11	111B157   696	4235018026	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	33.99957	-118.43071	Upgrade electrical service from 400 oh to 600 amps under ground, intercept to old service about four ft with STOW cable and derated for 67% and remove and cover the old meter and use the panel as branch panel. transformer and fuses provided.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52403	12041-10000-06507	6801 W HOLLYWOOD BLVD # 201	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	TENANT IMPROVEMENTS FOR A CANDY STORE W/SOME CANDY MAKING FACILITIES; COMBINE 2 TENANT SPACES. PLAN CHECK FOR POWER, ENERGY, AND EMERGENCY LIGHTING.16190 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52404	15041-20001-22272	8928 N WHITAKER AVE	91343	12	195B133   155	2688027004	RA-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.23311	-118.49926	Expedited per applicant request.Plan check for the addition of a 3 kWac system onto an existing 3.8 kWac system, for a total system size of 6.8 kWac. System addition consists of (1) inverter, (12) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52405	13041-20001-30410	3315 N CAHUENGA BLVD WEST	90068	4	159B181   570	2425026001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM			PC Info Complete	08/06/2014 12:00:00 AM	ADDRESS	34.13043	-118.35048	Change from previously approved plans.  Changes include relocate service equipment, additional of subpanel, recalculate load, and lighting.  All changes indicate by DELTA 1 and DELTA 2.  Plan check for power and energy.*****Previous Description*****PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT. ((submittal 2 for expedite fees)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52406	16041-10000-08883	4677 E WORTH ST	90063	14	135A233   328	5223002016	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Info Complete	12/15/2016 12:00:00 AM	ADDRESS	34.06234	-118.18141	Service upgrade 4000A on an (E) commercial build. Core & Shell, all loads are for future. PC for Power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52407	19041-20000-05378	6226 N COLFAX AVE	91606	2	177B169   283	2335032012	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	07/07/2022 12:00:00 AM	ADDRESS	34.18362	-118.3876	INSTALLING 151 NEW FIRE ALARM DEVICES PLUS 1 CONTROL PANEL FOR APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52408	17041-10000-35700	3780 S WATT WAY	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	PIN	34.01877902	-118.28765493	PC for power and energy for new three story building. Installing new 1200A 480/277V service, new panels, new circuits and equipment. Total area  27300 sqft.b#17010-10000-02957	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52409	19041-10000-48857	3321 W HYDE PARK BLVD	90043	8	105B185  1217	4006010034	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Issued	11/26/2019 12:00:00 AM	ADDRESS	33.98077	-118.33017	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52410	17041-10000-22671	14675 W RINALDI ST E & F	91340	7	213B149   125	2612015011	C2-1-CPIO	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.2813	-118.45299	Title 24 plan check.  T.I. to (E) retail space.  New lighting and receptacles.  Total area = 1,875 sq. ft.       Building permit #17016-10000-17752	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52411	12041-10001-14509	1429 N GOWER ST	90028	13	147A189    94	5546024804	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Approved	08/09/2012 12:00:00 AM	ADDRESS	34.09699	-118.32249	REVISION TO APPROVED PLANS. LIGHTING LAYOUT AND T24 ENERGY CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52412	19041-10000-12738	2712 N GRIFFITH PARK BLVD	90027	4	150A205    27	5433026040	C4-1D	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	07/09/2020 12:00:00 AM	ADDRESS	34.10715	-118.2726	PC T-24 only for a change of use from a laundromat to TI.  Area 2529SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52413	11041-10000-02543	8635 W 3RD ST MOT973W	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM			PC Approved	02/09/2011 12:00:00 AM	ADDRESS	34.07373	-118.38073	ALTERATIONS IN OFFICES  IN A MEDICAL OFFICE BUILDINGPERMIT OBTAINED  ON 11041-9000-01662PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52414	11041-20000-13559	8969 N WOODMAN AVE	91402	7	195B153   366	2639039021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40, 1199.00	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	PIN	34.23251159	-118.4387642	Plan check power and energy for ghange of use from retail to medical office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52415	11041-20000-24330	1880 CENTURY PARK EAST 11, 14, 15-Floors	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	12/14/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	Plan check T24 Energy/Emergency for corridors on floors 11, 14, and 15. New light fixtures and exit signs. Existing ckts.Fire/ Life safety existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52416	18041-10000-43922	1248 N ALAMEDA ST	90744	15	033B213    63	7428003048	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.78937	-118.24132	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52417	15041-10000-25712	20120 W VIA MEDICI	91326	12	219A115   350	2701041009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.29497	-118.57171	PV 1 ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY HOME. (2) INVERTERS 13.6KW INTERCONNECTED WITH THE MAIN SERVICE PANEL, (56) MODULES.***PERMIT FEE IS $0 PER STATE SENATE BILL #1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52418	16041-10001-13962	841 E MILWOOD AVE	90291	11	108B145   146	4241007031	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	33.99551	-118.46155	05/16/2016 CHANGES TO APPROVED SET, CHANGES INCLUDE SWITCHING PV MODULES FROM (SPR-E20-327-C-AC) TO (SPR-X21-345-C-AC)PERMIT: PERMIT PAID UNDER PCIS#16041-10000-13962PV1, rooftop solar installation with AC modules (18) SPR-E20-327-C-AC .    Standard plan is used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52419	13041-10001-28088	6055 S VERMONT AVE	90044	9	105B197   610	6003021023	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	33.98472	-118.29168	[[[[9/19/2014   PLANCHECK FOR T24 ENERGY TO MATCH THE LOCATION PER INSPECTORS REQUEST.]]]]]TITLE 24 ENERGY PLAN CHECK ONLY .  RESTAURANT. NO CHANGE IN OCCUPANCY. 8938 SQFT.  EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52420	15041-10000-36091	1611 N CAHUENGA BLVD	90028	13	148-5A187 299	5546007013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Closed	08/03/2017 12:00:00 AM	ADDRESS	34.10011	-118.32973	PC FOR POWER AND ENERGYR. EMODEL OF EXISTING 2-STORY RESTAURANT.( BEAUTY & ESSEX). NEW 800A SERVICE AND ADDITION OF  8 NEW LESS THAN 200A PANELS . TOTAL AREA 14033 SQ FT(INDOOR+ OUTDOOR)B# 15014-10000-04593	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52421	19041-10000-04530	13367 N BORDEN AVE	91342	7	225B149   196	2505027027	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.31434	-118.45233	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52422	16041-10002-32713	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	PIN	34.04222127	-118.45848597	Suppl App FA , adding 97 devices and 1 power suppl to an existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52423	15041-10000-04983	5060 W PICO BLVD	90019	10	129B181   999	5070016044	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	ADDRESS	34.04775	-118.34842	Title 24 plan check only.  Total area = 3,250 sq. ft.T.I. to existing building converting from retail to bakery space.  New 400 A service and associated power distribution equipment.  Changes to lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52424	15041-10001-07191			5	147B157   241	4356015022	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	PIN	34.09829254	-118.4261785	EXPEDITE PER CUSTOMER REQUESTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.6KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52425	19041-10000-29552	5800 W SUNSET BLVD	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			Reviewed by Supervisor	09/03/2019 12:00:00 AM	ADDRESS	34.09728	-118.31693	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING TENANT IMPROVEMENT(OFFICE TO OFFICE) - TOTAL AFFECTED AREA =  583 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52426	13041-20000-28900	9029 N DE SOTO AVE	91304	3	195B109    20	2779001035	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.23441	-118.58877	T24 FOR EXISTING RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52427	16041-10001-15317	13901 W VENTURA BLVD	91423	4	165B153   479	2271015015	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM			PC Approved	07/12/2016 12:00:00 AM	ADDRESS	34.14894	-118.43571	PC for enery only to a 7--eleven retail store. Scope includes the additoin of new liighting units only. Total sqft = 1137	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52428	17041-10001-29699	5326 E YORK BLVD	90042	14	156A227   462	5478004023	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.1198	-118.19937	DELTA 1 CHANGES TO APPROVED PLANS. CHENGING THE AC UNITS ON THE ROOF.PLAN CHECK ONLY. PERMIT #: 17041-10000-29699<<<<PC FOR 7/11 TENANT. PC FOR POWER AND ENERGY. FIRST TIME TENANT TO NEW LANDLORD SERVICE>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52429	16041-10000-24938	23369 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.15853	-118.63421	PC FOR ENERGY ONLY. CHANGE OF USE FROM TAKE OUT ICE CREAM PARLOR TO TAKE OUT JUICE BAR. TOTAL AREA 1574 SQ FT. B # 16016-10000-16370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52430	19041-20000-38707	5525 E ASH ST 1-18	90042	1	153A227   329	5469029033	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1835.20	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Issued	10/08/2019 12:00:00 AM	ADDRESS	34.11182	-118.19679	NEW 600 AMP SERVICE FOR 19 UNIT MULTIFAMILY BUILDING AND REPLACEMENT OF SUBPANELS, WITH NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52431	14041-10000-35366	1046 S SERRANO AVE	90006	10	129B193   559	5080017085	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	ADDRESS	34.05119	-118.30618	Installing new fire alarm system with central station for a new 20 units apartment building. 71 devices adn one control panel and one communication panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52432	18041-20000-46098	8911 S RAMSGATE AVE	90045	11	096B169  1009	4125012010	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Apartment			12/26/2018 12:00:00 AM			Verifications in Progress	09/02/2020 12:00:00 AM	ADDRESS	33.95621	-118.3828	New 30 unit 7-story apartment building with 2000A 208Y/120V service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52433	16041-20001-12929	19701 W VALDEZ DR	91356	3	165B117    64	2178032007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.15148	-118.56202	05/18/2016 Changes to an approved set of plans. Inverter size has changed to reflect field installation. Standard plan is being used.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter, (44) modules, and (1) combiner box. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52434	11041-20001-03820	1330 N ORANGE DR	90028	4	147B181  1086	5548023050	RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			03/10/2011 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Finaled	03/14/2011 12:00:00 AM	ADDRESS	34.09536	-118.34142	RE-PLAN CHECK FOR REPLACMENT OF EXISTING FIRE ALARM PANEL AND MANUAL PULL STATION.  ORIGINAL PLANS 09041-20000-13709 WERE LOST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52435	13041-10000-30413	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	33.97811	-118.39245	"PLACE OF ASSEMBLY, TENANT IMPROVENT FOR ""CINEMARK"" 3D THEATER. TOTAL AREA FOR LIGHTING WORK IS 6300 SQ FT. LOCATED IN METHANE BUFFER ZONE PER ZIMAS.""COMPLY WITH DEPARTMENT ORDER effective date 07/19/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". NOTE: STE NUMBER IS TO BE PROVIDED BY APPLICANT BEFORE THE APPROVAL OF THE PLAN, IF APPLICABLE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52436	14041-10000-32978	17655 W VINCENNES ST	91325	12	198B129   107	2766001032	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.24101	-118.51951	PV1.  Install 10.46 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52437	17041-20000-15373	15834 N PARTHENIA PL	91343	12	195B141   764	2673005022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	PIN	34.22804928	-118.47767061	install roof mounted pv system sized 8.2kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52438	12041-10000-14157	2710 W TEMPLE ST	90026	13	138A203   229	5156023911	PF-1XL	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.07287	-118.27623	Plan check power and energy for existing LAPD building. All new electical system with 1000A service. Building not designated Critical Operations Power System (COPS) per LAPD. Area located in methane zone. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52439	17041-10001-33239	1313 W SEPULVEDA BLVD	90501	15	042B193   827	7347018096	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Approved	06/21/2018 12:00:00 AM	ADDRESS	33.81424	-118.30074	Supplemental plan check only, permit is covered under master #17041-10000-33239. Changes due to field installation and are clouded and noted as Delta 6,7,8. Scope of changes: Replace and add couple of light fixtures, T24 calculation and lighting floor plan are revised accordingly; Add and remove some loads, panel schedules are revised accordingly.<<PC for power and energy for first time tenant fish restuarant.Installing 2 new panels, circuits, lights and equipment.Total area of 2803sqft. B 17016-10000-27013>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52440	19041-10001-41540	1475 N BEL-AIR ROAD	90077	5	147B149   458	4370018026	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM			PC Approved	10/21/2019 12:00:00 AM	ADDRESS	34.09756	-118.44635	Changes to approved set, changes include revising feeder schedule, going from copper to aluminum, and revising loads on panel schedules. All changes are clouded under delta 1Orginal scope((Power plan check for a new 600-Amp service located in a new single family dwelling unit. Scope includes (1) 600-amp service, (5) equipment, (4) main panels and other ckts. Note. Most of the permit fee is paid under combination permit, (15010-20000-03794)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52441	19041-10000-36487	601 S FIGUEROA ST 16TH FLR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM			PC Info Complete	09/26/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Energy plan check for an office T.I located on the 16th floor of a commercial building. Scope inlcudes new lighting and equipment with a total lighting area 20,000SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52442	13041-10001-31537	7242 N EASTHAVEN LANE	91307	12	186B089   699	2027022027	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.20278	-118.6477	Expdited RSES plan check per applicant request.(((PV1, Install 4.75 kW DC roof-mounted solar array for a 2-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 19 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52443	14041-20000-02493	6767 W FOREST LAWN DR SUITE 201	90068	4	162B181   617	5581028005	C1-1D	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.14432	-118.33993	T24 FOR EXISTING LOWRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 201	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52444	14041-10001-22930	3657 N MEADVILLE DR	91403	4	159B145    81	2279018009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.13598	-118.46847	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 7.905 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(31) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52445	19041-20000-44135	1262 E PALMETTO ST 1ST FLR	90013	14	126A217    44	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	09/22/2020 12:00:00 AM		Permit Finaled	07/16/2021 12:00:00 AM	ADDRESS	34.04005	-118.23347	New distribution, power, and light for first time tenant space improvements.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52446	16041-10000-11270	8370 N VANALDEN AVE	91324	12	192B121   559	2784020025	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.22247	-118.54905	PV1 rooftop solar installation 10kW AC system on SFD.  (45) CS6P-265P      (1) SE10000A-US     SE P-300 is used.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52447	10041-10000-21768	515 S FIGUEROA ST	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	REMODEL OF OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52448	12041-10000-14491	4356 W FOUNTAIN AVE	90029	13	147A201   282	5542023046	C4-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.09539	-118.28498	Plan check for energy only. restaurant. Emergency lights are existing. 1495 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52449	17041-20000-06285	8428 N VAN NUYS BLVD	91402	6	192B149   209	2638022040	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.22414	-118.44858	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR AMERICAN BEAUTY ACADEMY.  3620SQFT.   PLANCHECK ONLY.  PERMIT UNDER 17041 20000 02351.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52450	16041-10000-02590	3726 W 6TH ST	90005	10	135B193   877	5503026007	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	PIN	34.06331601	-118.30372719	T-24, CHANGE OF USE FROM RETAIL TO SIT DOWN COFFEE SHOP. NO CHANGE IN PARKING ENTERPRISE ZONE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. F.T 875.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52451	15041-20000-23319	21800 W OXNARD ST Suite 1060	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for Title 24 only. Project site is an existing high-rise commercial space. Project scope is a tenant improvement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52452	12041-10000-00781	1371 W JEFFERSON BLVD	90007	8	120B197   610	5040023027	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.02565	-118.29672	PLAN CHECK POWER FOR NEW DISTRIBUTION PANEL SUPPLYING TWO INJECTION  PUMPS. EXISTING SERVICES. SITE LOCATED IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52453	11041-20000-08958	8500 W BEVERLY BLVD #657	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			PC Approved	05/03/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	Plan check T24 energy (general/emergency) lighting for existing retail #657	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52454	19041-20001-47004	19656 W FALCON RIDGE LANE	91326	12	217-5A117 183	2701022028	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.28965	-118.56213	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE IN PV MODULE MODEL, SYSTEM DC SIZE CHANGED FROM 9.715 KW TO 10.15 KW, AC SYSTEM SIZE UNCHANGED, CHANGE MADE TO COVER PAGE, SINGLE LINE, AND ROOF LAYOUT PAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52455	12041-20001-17445	18600 W DEVONSHIRE ST Sale-Office	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.25704	-118.53922	Modification to previously approved set of plans.       <<<New panels and circuits for the sales office building.  Plan checked for T-24 and emergency lighting only.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52456	14041-10000-04277	2511 N DALY ST	90031	1	139-5A221 205	5204003020	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.07571	-118.21587	permit to be pulled at EPC counter. PC for energy only. Less than 400A per applicant - Inspector to verify. Meat room and electrical rooms have lighting changes.TI TO (E) RETAIL. CHANGE TO SMART & FINAL. 621 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52457	14041-20001-28670	8976 N LAUREL CANYON BLVD	91352	6	195B165   167	2629019021	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM			PC Approved	10/29/2014 12:00:00 AM	ADDRESS	34.23276	-118.40423	EXPEDITEPV2 COMMERCIAL ROOFTOP SOLAR. NEW SYSTEM DESIGN. THIS IS NOW AN 8KW SYSTEM. USING 32 MODULES. SINGLE INVERTER TRANSFORMER TYPE. 2 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52458	19041-20000-23523	22552 W NAPA ST	91304	12	192B097    49	2004016004	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.22564	-118.61836	PV1.  Install 11.7 kW DC / 10 kW AC roof mounted grid tied PV system.  (39) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52459	15041-10000-26870	864 S VERMONT AVE	90005	10	132B197   748	5077024038	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Closed	01/21/2020 12:00:00 AM	ADDRESS	34.0563	-118.29145	NEW 4-STORY COMMERCIAL BLDG WITH RETAIL AND ABO.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52460	15041-10000-20413	1519 W EWING ST	90026	13	144A211   322	5420037013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Expired	07/27/2017 12:00:00 AM	ADDRESS	34.08734	-118.249	PV1Install a roof-mounted solar array on a SFD. Interconnect with a (N) 125A load center, fed from existing 200A MSP.System size: 3.0kW. Ungrounded system. (15) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52461	14041-20000-34398	8926 N SUNLAND BLVD	91352	7	195B177   317	2404008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.23146	-118.3665	Plan check for power and energy. TI to charter school. All wiring and lighting is new, interior is completely redone. Services and main distribution sections are existing, all other equipment is new. 48,986sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52462	16041-10000-07491	11667 N PRAGER AVE	91342	7	213B165   248	2531026037	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.28226	-118.39635	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.0KWac. (26)MODULES- SUNPOWER 327 WATT MODULE(1)INVERTER-SB5000TL-US-22 AND (1)SB3000TL-US-22Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52463	18041-10000-00104	9925 N CANOGA AVE	91311	12	201B105    47	2747010036	[Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.25072	-118.59747	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 3850 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52464	17041-20000-33078	14000 N CAROL LANE	91342	7	228B141   514	2603026012	(Q)R1-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.32042	-118.48197	PV1.  Install 6.88 kW roof mounted grid tied PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52465	12041-10000-25856	21021 W ERWIN ST	91367	3	177B109     7	2149004007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.18304	-118.59175	Plan check for power and energy. New 7 story parking structure accessory to proposed apartment building. Low rise structure. Includes 6 electrical vehicle charging station and 34 station for future.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
52466	14041-20000-17700	1016 N COLE AVE	90038	13	144B185   888	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.08942	-118.32972	PC FOR POWER AND ENERGY PER APPLICANT REQUEST. NEW TRANSFORMER AND SUBPANEL. ADDED LAUNDRY CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52467	12041-10000-02690	625 S ST ANDREWS PL	90005	10	135B193   973	5504028017	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Public Safety Only			02/06/2012 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	08/28/2012 12:00:00 AM	ADDRESS	34.06262	-118.31173	New Fire alarm system. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52468	13041-20000-01230	1113 W 65TH PL	90044	8	105B197  1612	6014006007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2013 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	33.97993	-118.29413	New 3.36kw Rooftop PV system for an existing single family dwelling using Enphase Micro-Inverters.  The Plan Check is only for the PV System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52469	17041-20000-31103	511 S LUCERNE BLVD	90020	4	135B189   669	5505020014	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.06483	-118.32462	permit fee $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 15.3kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52470	17041-10000-18139	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	TITLE 24 FOR - Tenant improvement for American Airline club lounge (13000sf area) at Terminal 5. TOTAL AFFECTED AREA = 8973 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52471	16041-20000-02261	7277 N GLENHAVEN CT	91307	12	186B089   579	2027049025	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Expired	03/02/2018 12:00:00 AM	ADDRESS	34.20386	-118.64865	PV1. Intalling roof mounted PV system sized 9.6 kW. Interconnected with main service panel.(38) Kyocera KU265 Modules(1) ABB PVI-6000 Inverter(1) ABB PVI-3.6 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52472	19041-20000-49212	555 S MATEO ST BLDG 2	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	02/05/2021 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.03943	-118.23302	Power and lighting for coffee kiosk in commercial office building.  Plan check for power and energy. 2 separate electrical permits under same plan check approval:19041-20000-4921019041-20000-49213	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52473	10041-20000-24096	10800-10850 W PICO BLVD	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/03/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.04054	-118.4272	Install indoor/outdoor lighting in valet parking area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52474	18041-10000-46322	249 S LOS ANGELES ST	90012	14	129A213    47	5161026910	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	05/26/2020 12:00:00 AM	ADDRESS	34.04908	-118.24445	SEnate Bill 1222LB1414   NEW ROOFTOP SOLAR SYSTEM CONSIST OF 150 MODULES (Mitsubishi electric pv-MLE280HD2 280W) AND 5 CENTRAL INVERTERS (HIQ SOLAR TS480-8K).  SYSTEM SIZE IS 42.0KWdc and 37.059KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52475	18041-10000-15372	1028 N SWARTHMORE AVE #3-102	90272	11	129B125   834	4423016008	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.04774	-118.52527	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR NEW REATIL SPACE(WHITE BOX). TOTAL AFFECTED AREA = 1186 SQ. FT.B#18016-10000-12690	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52476	14041-10000-07613	4846 N KATHERINE AVE	91423	4	168B153   242	2248026003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Expired	09/20/2016 12:00:00 AM	ADDRESS	34.15893	-118.44311	PV1, INSTALL 4.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOME, INTERCONNECT WITH THE MAIN SERVICE.(14) MODULES:  CANADIAN SOLAR CS6X-305P(14) MICROINVERTER: ENPHASE MC4/H4 M250	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52477	10041-10000-25464	1513 S GRAND AVE 4TH Floor	90015	9	124-5A207 123	5134015027	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	05/24/2011 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.03622	-118.26632	NEW MEDICAL CLINIC ON THE 4TH FLOOR.  FIRST TIME OCCUPANCY. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52478	18041-30000-27634	1545 S FAIRFAX AVE	90019	10	129B173   994	5068021007	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.04831	-118.36762	Install New Fire Alarm system on a New 4-story 10-unit apartment building over one level subterranean garage. (1) Panel, (66) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52479	13041-10000-13108	15454 W SHERMAN WAY	91406	6	183B145    74	2222030014	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.20091	-118.47008	pc for power only. REPLACE 2 CHILLERS & 1 COOLING TOWER W/ VFD. RELOCATE FEEDERS FOR NEW equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52480	10041-10000-24823	5056 N VAN NUYS BLVD	91403	2	171A151    91	2248009901	OS-1XL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	34.16369	-118.4485	Fire alarm system for 3 separate buildings.  The FACP is located in building B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52481	13041-10000-02184	8500 W BEVERLY BLVD # 671	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	03/15/2013 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI for existing retail space in beverly center mall. Title 24 only and emergency circuit. 2993 sqrft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52482	17041-10000-15332	1601 N VINE ST 5TH-6TH FLRS	90028	13	148-5A187 301	5546009154	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.09996	-118.32693	FULL PLAN CHECK FOR A TENANT IMPROVEMENT IN THE 5TH AND 6TH FLOOR. ADDING NEW PANELS WITH A NEW ADDED LOAD GREATER THAN 400 AMPS. NEW LIGHTING. AREA: 26,824 SQFT.B#17016-10000-11792	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52483	17041-10000-30595	221 E PICO BLVD	90015	14	124-5A209 133	5145028009	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Issued	12/04/2017 12:00:00 AM	ADDRESS	34.03547	-118.25864	PC FOR SERVICE UPGRADE TO 600A 120/240 3PH.SCOPE INCLUDES NEW ELECTRICAL ROOM WITH NEW SERVICE SECTION, CIRCUITS  AND LIGHTS. TOTAL AFFECTED AREA 97 SQ.FT TI to in (E) store building to inlcude new partitions for (N) 6'x16' electrical room.  B# 17016-10000-17113	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52484	13041-10000-28852	3901 N EAGLE ROCK BLVD BLDGA	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.11925	-118.23127	"INSTALLING FIRE ALARM SYSTEM,   APARTMENT BUILDING ""A"" (1 OF 7 buildings)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52485	16041-10000-10771	2619 W EXPOSITION BLVD	90018	10	117B189    81	5044024046	[Q]CM-1VL-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.02047	-118.32419	PC FOR POWER AND ENERGY. T.I FOR A COMMERCIAL BUILDING. NEW 800A SERVICE, CHANGE OF USE FROM WEARHOUSE TO  COMMERCIAL OFFICE  1-STORY 14,475 SF. STRUCTURE WITH  MEZZANINE. TOTAL AREA 19627 SQ FT(OUTDOOR+ INDOOR).B# 16014-10000-00639	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52486	15041-10000-41339	1141 W 2ND ST	90012	1	133-5A209 224	5152009901	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Expired	06/28/2018 12:00:00 AM	ADDRESS	34.0588	-118.25625	Permit fee is $0.00 due to Senate Bill 1222. PV2 COMMERCIAL CARPORT PV SYSTEM. TOTAL SYSTEM SIZE 276KW AC. USING TOTAL OF 1107 MODULES. THIS IS PV ONLY SERVICE. FEED IN TARRIF. SYSTEM COMPLIES WITH MASTER CUP. SYSTEM IS RESERVING CAPACITY FOR FUTURE EXPANSION.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52487	15041-20000-02537	10515 N COLLETT AVE	91344	12	207B141   691	2668006017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.2616	-118.48384	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52488	19041-10000-25160	6711 S SEPULVEDA BLVD	90045	11	102B165    39	4110001004	C4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Apartment			07/05/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Closed	03/17/2021 12:00:00 AM	ADDRESS	33.97915	-118.39453	PC FOR TEMP POWER FOR A NEW 8-STORY APARTMENT BUILDING OVER 1-LEVEL OF SUBTERRANEAN PARKING.SCOPE INCLUDES 800A 277/480V 3PH SERVICE WITH EQUPIMENT AND PANELS. B#19020-10000-00361	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52489	18041-30001-41474	633 W 5TH ST 16TH FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.05099	-118.25468	01/15/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2 and 3. Restrooms have been added to the scope of work. Exit signs have been added. All changes have been reflected onto the Title 24 compliance forms.*****Original Work Description*****PLAN CHECK FOR T24 ONLY, FULL FLOOR INTERIOR OFFICE TI. ON THE 16TH FLOOR. TOTAL AREA: 20,870 SQ.FT(B# 18016-10000-34017)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52490	19041-30000-42283	2049 S CENTURY PARK EAST SUITE#1450	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Energy PC only, Area of scope 7132sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52491	13041-20000-10097	17221 W SUNBURST ST Pv-1	91325	12	195B133    27	2690001004	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM			Reviewed by Supervisor	05/02/2013 12:00:00 AM	ADDRESS	34.23462	-118.50944	PV-1. Transformerless inverter. one 4.6kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52492	16041-10000-20790	1302 W 65TH ST	90044	8	105B197  1496	6014008041	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Expired	07/18/2018 12:00:00 AM	ADDRESS	33.98052	-118.29825	INSTALL NEW 6.89 KW DC / 5.0KW AC  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(26) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52493	15041-10000-41539	3470 W 6TH ST # 3	90005	10	135B197  1033	5502029026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	PIN	34.06333997	-118.29761911	ALTERATIONS IN A RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52494	17041-10002-42742	981 S ELDEN AVE 1-16	90006	1	129B197   158	5076003014	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Apartment			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.05302	-118.28797	Change to approved set. Changes include revising single line diagram to reflect as built. All changes are clouded under delta-2 only.Note: Permit is paid under master application 17041-10000-42742	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52495	14041-20000-30259	21600 W OXNARD ST 19TH FLOOR	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.179	-118.6002	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS. 19TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52496	10041-20000-13590	6061 N TOPANGA CANYON BLVD	91367	3	177B101   111	2146025005	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	07/22/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.18066	-118.60615	Plan check T-24 Energy (general/emergency) lighting for existing Chevron  gas station.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52497	18041-10000-32018	2339 W WASHINGTON BLVD	90018	10	126B193   919	5073018901	[Q]CM-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Apartment			08/22/2018 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	04/30/2021 12:00:00 AM	ADDRESS	34.04009	-118.31327	PLANCHECK FOR POWER AND ENERGY. New 4-story, 64-unit, affordable housing apartment building over 1 level of subterranean parking . Total 5-typical unit.NOTE. FEE PROVIDED BY APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52498	12041-10001-24445	108 W 2ND ST #104	90012	14	130-5A213 201	5149006010	C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.05097	-118.24511	Tenant improvement in existing restaurant. Plan chk is for title 24. Permit was obtained on 12041-10000-24445RELOCATE (8) RECEPTACLES & RELOCATE (12) LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52499	18041-20000-13490	7000 W ROMAINE ST Rest Room	90038	4	144B181   631	5532010050	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Approved	04/12/2018 12:00:00 AM	ADDRESS	34.08879	-118.34215	Plan check for title 24 only in existing Men and \Women Rest Room T.I. Total area: 840 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52500	15041-20002-14171	6316 N TOPANGA CANYON BLVD 1115-B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM			PC Approved	10/09/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	10/07/2015 Changes to an approved set of plans. Revisions have been made to match field installation. All changes have been clouded and marked as Delta 12. *****Previous Work Description*****Plan check for 1st time tenant for DAVIDsTEA Suite 1115-B. New interior reatil  alteration for tea retail store. Tenant work includes new light, electrical, HVAC and stroe front. Total area: 1490 sq ftSupplemental permit to collect fees for (1) additional inspection per inspection Correction Notice dated 9/24/2015.  This permit does not authorize any additional work or extend the expiration date of the original permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52501	13041-10000-24709	153 S IRVING BLVD	90004	4	138B189  1185	5516004029	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.0716	-118.31855	PV1.  Install 5.72 kW DC roof-mounted solar array of 22 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52502	13041-10000-16921	3540 E MISSION ROAD	90031	1	136-5A227  63	5211021901	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	PIN	34.06665286	-118.20074688	Outdoor parking lot lighting.  Title 24 plan check only.  Permit to be issued  at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52503	17041-10000-05237	15400 W SHERMAN WAY	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.20099	-118.46839	FULL PC FOR POWER AND ENERGY. CHANGE OF USE TO OFFICE. SCOPE INCLUDES NEW PANELBOARDS, NEW CIRCUITS, AND NEW LIGHTS. NEW CONNECTED LOAD >400A. TOTAL AFFECTED AREA IS 41801 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52504	13041-20002-33303	5260 N BELLINGHAM AVE	91607	2	171B165   327	2347020015	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			03/21/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.1663	-118.39912	SUPPLEMENTAL APPLICATION TO REVISE SERVICE TYPE. THIS IS NOW A 3PHASE 4 WIRE 240 HIGH LEG. PERMIT FOR ELEVATOR CONNECTION TO HOUSE PANEL. NO CHANGE IN LOADS. CHANGES CLOUDED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52505	19041-10000-35826	6390 W DE LONGPRE AVE	90028	13	147A187   290	5546016002	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	11/19/2020 12:00:00 AM	ADDRESS	34.09602	-118.32852	Fire alarm system with partial voice evacuation for new high-rise building.  (1009) signaling line and notification appliance devices, (40) remote power supplies, and (3) FACPs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52506	15041-10002-05395	3201 S HOOVER ST	90007	9	121-5A201 145	5039020034	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.02548	-118.28442	03/30/2016CHANGES TO AN APPROVED SET OF PLANS, PC TO VERIFY THE SETTING OF BREAKERS ON THE SINGLE LINE DIAGRAM UNDER DELTA 27. PC ONLY. (((Full plan check for a central plant in a single story building (USC village, bld #1). Scope of work includes medium voltage, and all work is under building #1 only. note. customer paid with preprint check, and there are (6) lighting circuits need to be paid when permit is pulled.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52507	15041-20000-35617	6540 N BELLINGHAM AVE	91606	2	180B165   465	2322005030	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.18973	-118.3986	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZEl 3.3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52508	14041-20000-33608	9301 N TAMPA AVE ROOMS 718-724	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM			PC Approved	12/09/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI TO EXISTING STORAGE ROOMS. PC FOR T24 ENERGY ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52509	13041-20000-15639	11100 W SANTA MONICA BLVD 20TH FLOOR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.04726	-118.44465	Change to lighting in an existing high-rise office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52510	11041-10000-00229	2101 E PACIFIC COAST HWY	90744	15	033B213    10	7428007003	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	33.79173	-118.23549	REPLACE AN EXISTING FIRE PUMP SYSTEM IN THE NORTH PLANT OF TESORO REFINARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52511	13041-20000-08298	1865 W BLAKE AVE	90039	13	147A213    82	5442008036	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/01/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Expired	04/28/2015 12:00:00 AM	ADDRESS	34.09832	-118.24348	Change to lighting in an existing Workspace for an artist.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52512	16041-10000-39243	111 E AVENUE 26	90031	1	139-5A221 170	5205021002	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.0766	-118.21516	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL STORE(RITE AID). SCOPE INCLUDES NEW LIGHTS FOR THE RESTROOMS, LOUNGE, AND CONSULTING AREAS. TOTAL AFFECTED AREA IS 480 SQ. FT. B#16016-10000-26603	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52513	11041-20000-16826	18017 W CHATSWORTH ST	91344	12	207B125   100	2715025054	(Q)C2-1L	North Valley	Granada Hills - Knollwood			1112.02	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.26492	-118.52553	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR UPS STORE. PERMIT FOR NEW CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52514	14041-10000-28281	8635 W 3RD ST Ste 590	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.07373	-118.38073	T.I. to medical office.  Installation of lighting and recepticles.  Total area = 5341 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52515	14041-10000-17646	1424 S BENTLEY AVE	90025	5	129B149    30	4324016031	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.05133	-118.44604	plan check for power and energy. PROPOSED 4 STORY 8 UNIT APARTMENT BUILDING WITH ROOF AND DECK + SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52516	12041-10000-11131	5742 S MORGAN AVE	90011	9	108B213   649	5105020022	MR1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			05/15/2012 12:00:00 AM	05/15/2012 12:00:00 AM		Permit Finaled	04/02/2013 12:00:00 AM	ADDRESS	33.99008	-118.24441	New stand-alone industrial building with 200A service.  Non-hazardous location per applicant.  PLAN CHECk only for Energy, no emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52517	19041-10001-20647	1303 W ANAHEIM ST	90744	15	030B201   196	7416003019	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	33.77925	-118.2784	Changes to an approved set for a TI in an existing warehouse, T24 only. Note all changes are under delta 1. Note Plan check only. Orginal Scope(TI IN AN EISTING WAREHOUSE. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52518	16041-10000-43865	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			Corrections Issued	12/29/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for conduit only.  Plan reflect relocation  electrical conduit for infrastructure underground. Plan check only highlighted on the plan, associated with LAWANote: Permit for conduit will be pull at the later time	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52519	18041-20000-14395	2189 E WHITTIER BLVD UNIT C	90023	14	124-5A221 121	5183021023	R3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.03614	-118.21937	Plan check for power and energy in existing space T.I. coin laundry.  Install 600A equipment.  Total area: 3,223 sq ft.COMPLY WITH DEPARTMENT ORDER effective date 09/15/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.B# 18016-20000-11498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52520	17041-10002-06760	1101 S VERMONT AVE #102	90006	1	129B197   480	5078027037	C2-1, R4-1VL	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.05073	-118.29194	"Change to approved set by replacing lighting fixture ""C"" and ""D"" on the floor plan. All changes under delta_2 only.(((T-24, PC FOR ENEGY ONLY. T.I. FOR EXISTING RESTAURANT TO REMODEL DINING AREA, SUSHI BAR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2745 SQ. FT.   ALL WORK PER ENGINEERING PLANS.  A-OCCUPANT LOAD < 100. b#17016-10000-04693)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52521	12041-20000-20418	14006 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	New Lighting in food court tenant. Energy only. Load less than 400 amps, occupancy less than 99. Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52522	17041-20000-44782	14119 W RIVERSIDE DR	91423	4	168B153   430	2248024015	[Q]C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	33.9787	-118.31759	Plan check for power only. New 1200A 120/208V 3ph 4w service for (E) commercial building (Trader Joe's). Refeed existing panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52523	19041-20000-32659	15755 W SATICOY ST	91406	6	186B141    61	2206011052	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	03/08/2021 12:00:00 AM	ADDRESS	34.20857	-118.47675	Plan check for New Fire alarm system in multi-family building new fire alarm devices: 96 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52524	18041-20000-33146	4828 N SUNNYSLOPE AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	05/19/2021 12:00:00 AM	ADDRESS	34.1586	-118.42623	Plan check for a fire alarm system for a 3-story apartment building. System consists of (1) FACP, (1) annunciator, and (55) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52525	17041-10000-10863	1541 S PALOS VERDES ST	90731	15	012B201   400	7456020017	R2-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	33.72984	-118.28153	PC FOR PV SYSTEM ROOF MOUNTED. USING 3KW INVERTER WITH POWER OPTIMIZERS. USING 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52526	16041-20000-10853	1301 N COLLINGWOOD PL	90069	4	144B169    86	5560003002	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.09458	-118.38367	Plan check for power only. New SFD with 1000A service. 2 stories over a basement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52527	12041-10000-16651	13450 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15935	-118.42644	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #11	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52528	17041-10000-34653	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	33.97704	-118.40702	PC for T24 only for office TI. Installing new lights and receptacles. Total area of 1887 sqft. B#17016-10000-26252	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52529	14041-20010-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			10/03/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Closed	05/11/2020 12:00:00 AM	ADDRESS	33.95713	-118.3847	10-03-2018 Changes to an approved set of plan. Changes include addition of exit signs and fire smoke dampers on the 1st, 2nd, 3rd, and 4th floor. Total 19 exit signs and 4 fire smoke dampers connected to existing circuit. All changes has been clouded as delta 15.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52530	15041-10000-07591	757 S TOWNE AVE	90021	14	126A213   543	5146027029	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.03833	-118.24676	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACE HID LIGHTING TO LEDS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 5700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52531	13041-20001-33726	484 S SAN VICENTE BLVD	90048	5	135B173   219	5510005035	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	34.06911	-118.37479	Changes from previously approved plans.  Change to indoor and outdoor lighting only.  Plan check for energy only.Note: Permit is under the original application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52532	17041-20000-16312	10321 N WYSTONE AVE	91326	12	204B121    93	2728019011	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.25797	-118.54709	Plan check for solar pv system, roof-mounted on SFD.12.6kW ungrounded system (7.6+5).(40) 320W pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52533	17041-10001-36002	326 W 58TH ST	90037	9	108B201  1296	5101040009	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	33.98958	-118.27935	Off hour plan check feesRoof mounted PV system.System size 56KVA consisting of two inverters rated at 28KVA each, using 151 modules (Q.Peak G4.1-300),	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52534	19041-10000-19752	1403 E 21ST ST	90011	9	120A211   390	5119030020	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.02099	-118.24952	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52535	16041-20000-04082	17331 W CUMPSTON ST	91316	5	174B133   784	2257011014	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.16954	-118.51117	plan check for PV roof mounted system. System size 9.6 kW with 40 PV modules and 40 microinverters connected to 400 A panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52536	13041-20000-06353	16030 W VENTURA BLVD 240	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.15598	-118.48247	Change to lighting only, no other work in an existing office space on the 2nd floor of an existing high-rise office building.  Load is less than 400 amps per the applicant.  Load greater than 400 amps (INCLUDING WORK FROM OTHER FLOORS) will require full plan review, subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52537	18041-20000-41432	10718 W ACAMA ST 1-5	91602	2	165B177   956	2423029028	RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Apartment			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.1457	-118.36385	new fire alarm system 65 devices and facp.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52538	16041-20000-03490	15300 W ANTIOCH ST	90272	11	129B125   627	4412003006	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04689	-118.52616	TI to (E) commercial space being used as a break room/storage room.  (E) panel per contractor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52539	16041-20000-10129	12423 N GLADSTONE AVE #18	91342	7	219B161   251	2525018057	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.29571	-118.4121	Plan check for energy only. TI to existing commercial building. New lighting (incl. emergency). 1,276sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52540	11041-10002-18357	6750 W SANTA MONICA BLVD	90038	4	144B185   764	5532027016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.09057	-118.33767	Modification to previously approved set of plans to remove main breaker and use lockable panel breakers instead.            <<<<<<<<ADDITION OF SECOND LEVEL OFFICE AND EXTERIOR DECK. REPLACE EXISTING WINDOWS/DOORS.(((((((((( CHANGES MADE TO PREVIOUSLY APPROVED SET ADDITION OF NEW CKTS AND NEW PANEL AND TITLE 24.))))))))))))))))))))))))))))>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52541	14041-10000-17500	2049 S CENTURY PARK EAST SUITE 2500	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 FOR HIGH RISE OFFICE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52542	19041-10000-38602	9049 N WOODMAN AVE	91331	6	195B153   158	2639033013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	34.23405	-118.43978	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFITS KITS INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52543	18041-20002-48782	3984 N TARRYBRAE TER	91356	3	162B117   115	2180004017	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	34.14229	-118.56067	Changes to an approved set of plans.  Reconfiguration of AC portion of system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52544	14041-10001-13342	14959 W LANARK ST	91402	6	189B145    22	2209010002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.21801	-118.45947	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52545	15041-20000-24355	10455 N SUNLAND BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.25996	-118.3265	ADDITION & EXTERIOR T. I. TO (E) RETAILpc for t24 energy only for new outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52546	17041-10000-07291	7610 S HALLDALE AVE	90047	8	099B193   145	6018023003	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Issued	03/07/2017 12:00:00 AM	ADDRESS	33.97059	-118.30231	PC FOR PV ROOF MOUNTED SYSTEM USING 12 MODULES AC TYPE. TOTAL OF 3.8KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52547	19041-10000-44486	1135 N MISSION ROAD	90033	14	133-5A223  21	5210007030	M2-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.06144	-118.21353	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52548	16041-30000-21204	2180 S WESTWOOD BLVD 2F, 2G, 2H	90025	5	126B157   253	4321012071	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.04421	-118.4318	Plan check for Title 24 only. Project site is an existing commercial tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,340 sq. ft.Note: Building application has been generated under 16016-30000-08345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52549	16041-20000-12395	201 N FIGUEROA ST 13TH FLR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for Title 24 only. Project site is the 13th floor of an existing commercial building. Project scope is a tenant improvment. Total lighting area = 5,933 sq. ft.Note: Building permit has been pulled under 16016-10000-03884	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52550	14041-20000-28713	20558 W TIARA ST	91367	3	174B109    25	2151018048	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Closed	07/28/2015 12:00:00 AM	ADDRESS	34.17699	-118.58155	Changes from previously approved plans.  Upsize from 5.61KW to 6.375KW, upsize inverters and additional modules.  *****Previous Description*****PV1.  Install 5.355 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.  Previous application 14041-20000-20275	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52551	15041-10000-29803	26640 S WESTERN AVE 1-K	90710	15	030B193   177	7411009024		Harbor				2933.06	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	33.78015	-118.30862	Energy plan check for TENANT IMPROVEMENT FOR AN EXISTING MASSAGE PARLOR. Scope includes new lighting and receptacles; total area is 1290-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52552	14041-10001-17195	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.27455	-118.56289	REVISED PLANS TO INCORPORATE FIELD CHANGES-DELTAS C AND 2Plan check for power and lighting.  Total area = 126,234 sq. ft. conditioned, 54,763 sq. ft. outdoor.Service, pannels, lighting, for new church.  Place of assembly. Future eqwuipment: (A/V equipment) .PLAN CHK IS FOR CORE AND SHELL; PLANS SHALL BE SUBMITTED FOR NEW CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52553	17041-20000-26581	400 S CATALINA ST	90020	10	135B197   500	5502011026	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			08/03/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.06707	-118.29525	Plan check for power and energy. Project site is a new 5-story, 61-unit apartment building with 1 level of below grade parking. Work includes a new 1,600-amp service and a total lighting area of  38,945 sq. ft.Note: Building permit has been issued under 15010-20000-04491	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52554	16041-20001-41299	3217 S CLUB DR	90064	5	123B165   512	4316026014	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.03398	-118.40209	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP. Derating main breaker to 175A. 11.4kW ungrounded system. (45) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52555	11041-10000-09749	202 W 1ST ST 3rd Floor	90012	14	130-5A213  10	5149001006	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Info Complete	05/12/2011 12:00:00 AM	ADDRESS	34.05285	-118.24474	TI IN AN EXISTING OFFICE AREA ON THE 3RD FLOOR OF LA TIMES BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52556	18041-30000-39984	4847 W BEVERLY BLVD	90004	4	138B189   379	5522028015	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	04/12/2021 12:00:00 AM	ADDRESS	34.07636	-118.31517	PLANCHECK FOR POWER AND ENERGY (N) 4 STORY APARTMENT BUILDING (16-UNITS) OVER A BASEMENT PARKING GARAGEBUILDING PERMIT # 17010-30000-05074	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52557	15041-10000-04470	505 N HAYWORTH AVE	90048	5	141B177  1154	5527019011	R3-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.08027	-118.36291	New fire alarm system for a 3-story building, project including (1) Fire alarm panel, (1) annunciator, & (31) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52558	15041-10000-01265	11196 W PENDLETON ST	91352	6	198B173   109	2408034023	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.23689	-118.37512	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 10660 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52559	19041-20000-14095	5525 N ETIWANDA AVE 312	91356	3	174B125   518	2160011026	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.17048	-118.53094	INSTALLATION OF OUTLETS AND RELOCATION OF EXISTING X RAY MACHINE TO NEW X RAY ROOM CONVERTED FROM EXISTING WAITING ROOM IN EXISTING MEDICAL BUILDING IN SUITE 312.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52560	13041-20000-13693	925 W BLOOM WALK RM 103	90089	8	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.02018	-118.2892	PLAN CHECK ONLY FOR CONTROLS. T24 ENERGY ONLY. NO CHANGE IN LIGHTING, NO CHANGE IN FIXTURES. NO CHANGE IN PARTITIONS. PLAN CHECK FOR CONTROL OF FIXTURES ONLY. WORK DONE IN ROOM 103 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52561	19041-20001-23192	5670 W WILSHIRE BLVD 13TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			Corrections Issued	08/12/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	7/18/19changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.  ((((TI IN COMMON AREAS & CORRIDORS OF THE 13TH FLOOR. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.  1,072 SQR FT.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52562	17041-10000-08997	21025 W OSBORNE ST	91304	3	195B105    42	2779048008	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.23318	-118.59167	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES FOR OUTDOOR USE. TOTAL AREA 1650 SQ FT. INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52563	14041-20000-24834	7010 S HOOVER ST Unit #3	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #3. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52564	17041-30000-06869	159 S LA BREA AVE	90036	5	138B181  1114	5513019038	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.07196	-118.34423	Plan check for Title 24 only. Project site is an existing tenant space. Project scope is a tenant improvement. Total lighting area = 3,266 sq. ft.Note: Building application has been generated under 17016-30000-04875	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52565	12041-10000-18719	8500 W BURTON WAY	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Closed	04/15/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	DELTA 4 CHANGES TO THE APPROVED PLANS.     (((((((((((( Revision to previously approved set , change of out door and indoor lits and title 24, new added ckts, relocation and reckting..  8-9-12  ))))))))))))))))))))))))New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52566	16041-20000-35284	9720 N DONNA AVE	91324	12	201B121   364	2762032032	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.24766	-118.5474	Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter, (40) modules, (1) load center, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52567	18041-10000-40415	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.06488	-118.47066	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52568	14041-10000-16582	11620 W WILSHIRE BLVD 500	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	permit to be pulled at EPC counter only. Plan check for energy only. Suite 500. High rise with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52569	17041-10001-16895	4680 N EAGLE ROCK BLVD	90041	14	159A221   231	5685026010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.12969	-118.21667	12-21-2017 Changes to an approved set of plan. Changes to an approved set of plan. Changes include remove lighting fixture B, C, and E and replance with lighting fixture A. Changes has been clouded as delta 1. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52570	13041-10000-06741	4554 N SANCOLA AVE	91602	4	168B177   924	2420036003	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2013 12:00:00 AM	03/15/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.15368	-118.35366	SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 5.6 KW. TOTAL OF 26 UNITS. USING ENPHASE MINCROINVTERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52571	14041-10000-19646	1165 N MCFARLAND AVE	90744	15	033B209  1188	7423027065	(T)(Q)RU-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	33.78706	-118.25325	SOLAR PV STANDARD PLAN. CENTRAL/STRING INVERTER SYSTEMS FOR 1 AND 2 FAMILY DWELLINGS.  SYSTEM SIZE: 5.1 kW. total # of inverters installed: 1. Inverter AC output rating: 4200 watts.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52572	14041-10000-31771	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR RESTAURANT IN THE SHERATON AT THE BLOC; NOTE THAT THE OWNER IS DEVELOPING THIS SPACECORE AND SHELL PERMITTED ON 14041-10000-14771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52573	16041-10000-44431	517 N HARVARD BLVD	90004	13	141B193  1151	5521011024	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			12/19/2016 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.0805	-118.30471	New 9-unit, 2-story w/ mezzanine apartment building with parking garage at grade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52574	14041-20000-06844	19300 W ESPINOSA ST	91356	3	165B117   239	2177005001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.14906	-118.55383	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.6KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52575	13041-10000-06609	6840 N RESEDA BLVD	91335	3	183B125   874	2125010019	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.19506	-118.53584	PLAN CHECK FOR TITLE 24. TENANT IMPROVEMENT IN AN EXISTING STARBUCKS (1668 SQUARE FEET).  PERMIT ISSUED UNDER SUPPLEMENTAL APPLICATION 13041-10001-06609	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52576	17041-10000-29646	1258 W 21ST ST	90731	15	012B193  1161	7460021018	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2973.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	33.72532	-118.30482	PC for single family PV system. Total system size is 3.8kW. Installing one 3.8kW central inverter, 12 new modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52577	16041-10000-14036	1562 W 49TH ST	90062	8	111B193   957	5016028006	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Expired	05/23/2018 12:00:00 AM	ADDRESS	33.99903	-118.30551	PV1, INSTALL 2.3 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(11) MODULES: HYUNDAI HIS-M250MG(11) M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52578	18041-10000-27075	8548 N RESEDA BLVD	91324	12	192B125   161	2786006003	C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Apartment			07/19/2018 12:00:00 AM	07/13/2020 12:00:00 AM		Permit Finaled	10/29/2021 12:00:00 AM	ADDRESS	34.22606	-118.53587	PC POWER CHECK. SCOPE INCLUDES A NEW 800A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTINO BOARD, NEW PANELBOARDS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 13,382 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52579	12041-10000-03512	11600 W WILSHIRE BLVD Main-Lobby	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM			PC Approved	02/15/2012 12:00:00 AM	ADDRESS	34.05034	-118.45947	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR INTERIOR RENOVATION OF MAIN LOBBY LOCATED ON THE GROUND FLOOR OF AN (E) 5 STORY MEDICAL OFFICE BUILDING. NO WORK IN PATIENT CARE AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52580	19041-20002-04642	12300 W 1ST HELENA DR pv1	90049	11	129B141   246	4405039011	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.0519	-118.47793	03/18/2019 Changes to an approved set of plans. Distribution B panel OCPD has been derated down to 150 Amps.*****Original Work Description*****PV1.  Install roof mounted PV system sized 18.3 kW AC interconnected with MSP.  $0 permit fee per State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52581	15041-10003-33019	3350 W WILSHIRE BLVD	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/25/2020 12:00:00 AM	ADDRESS	34.0615	-118.29586	UPDATE PLANS TO SHOW ALL CHANGES MADE TO PERMITTED SET OF PLANS. CHANGES INCLUDE NEW SWBD TO REDISTRIBUTE POWER TO EXISTING LOADS . RESIDENTIAL DIST BOARDS SUPPLIED FROM 300KVA  TRANSFORMERS. CHANGES ARE CLOUDED.(((((CONVERSION OY 12-STORIES/BASEMENT OFFICE/GARAGE TO 216 ADAPTIVE REUSE UNITS AND RETAILS ON THE 1ST FLOOR.BLDG PERMIT 13016-10000-26033	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52582	16041-10001-10135	9107 N VAN NUYS BLVD	91402	6	198B149   542	2651009055	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.23588	-118.45045	07/27/16CHANGES TO AN APPROVED SET OF PLANS.ALL CHANGES ARE MADE UNDER DELTA B. CHANGES INCLUDE RELOCATING THE MANUAL AREA CONTROLS FOR LIGHTING FIXTURES. NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-10135((((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS FOR INDOOR AND OUTDOOR. TOTAL AFFECTED AREA IS 3675 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52583	15041-10002-06920	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.06326	-118.20213	REVISION TO THE APPROVED SET OF PLAN, ALL CHANGES IS UNDER DELTA N1:ADD AND REMOVE BRANCH CKTS, CHANGES ON T-24.Plan check hours charged due to initial applicant submittal of wrong set of plans. (((New 5 story Medical Building. Includes Power & Energy and OSHPD  3 PLAN REVIEW.Core & Shell was approved under 14041-10000-29044<<Fee Calcs were provided by applicant with a preprinted check. Fees to be verified during EPC>>)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52584	12041-10000-10925	8901 N ONEIDA AVE	91352	6	195B165   342	2631019048	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.23117	-118.3958	7.85 kw solar pv system , roof mounted, one story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52585	19041-20000-35644	1616-1622 N MARTEL AVE	90046	4	147B181   322	5550016050	R3-1	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.10041	-118.35005	Power and lighting for new parking structure.  Plan check for Title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52586	15041-10000-05317	8157 N LANKERSHIM BLVD	91605	6	192B169   634	2310007024	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.21902	-118.38801	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 14776 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52587	18041-10000-01311	17331 W TRAMONTO DR Bldg # 3	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 3 (CAMPUS STYLE)SCOPE INCLUDES 105 DEVICES AND 2 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE.B#15010-10001-03651BUILDING 3  (PLAN A1/ A1R)  8 UNITS AND 4 STORY  TYPE IIA  APARTMENT  BUILDING WITH  TYPE IB GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52588	15041-20001-12906	7665 N VICKY AVE	91304	12	189B097  1173	2013031009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	34.2102	-118.61976	EXPEDITE PER APPLICANT REQUESTPV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel(20) Sunpower SPR 327 Modules(1) Sunpower SPR 6002 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52589	18041-10000-28738	18337 W VENTURA BLVD	91356	3	171B125    86	2160009030	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Info Complete	07/31/2018 12:00:00 AM	ADDRESS	34.1673	-118.53189	T-24, PC FOR OUTDOOR LIGHTING ONLY, EXISTING BANK OF AMERICA SCOPE OF WORK INCLUDES NEW OUTDOOR LIGHTING. TOTAL SQ. FT. 18000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52590	11041-20000-16697	2121 S WESTWOOD BLVD	90025	5	126B153   180	4322001016	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM			PC Approved	08/08/2011 12:00:00 AM	ADDRESS	34.04456	-118.43252	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR NEW 2 STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52591	10041-10000-19388	11355 W OLYMPIC BLVD 3rd-floor	90025	11	126B153  1080	4260003008	[Q]C2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	01/14/2011 12:00:00 AM	PIN	34.03771362	-118.44301473	Ti in an existing restaurant. Plan check is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52592	10041-10000-17757	1017 N ORANGE DR	90038	10	132B181   749	5084013003	RD1.5-1	Central	Wilshire			2162.00	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	ADDRESS	34.08943	-118.34178	TENANT IMPROVEMENT IN CLASSROOMSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52593	13041-10000-32751	1500 W PACIFIC COAST HWY BLDG E	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING E THIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52594	17041-20000-32995	1440 N GORDON ST	90028	13	147A191   118	5545014045	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			09/14/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	08/12/2020 12:00:00 AM	ADDRESS	34.09687	-118.31997	New 4-story, Type VA, 41-Unit apartment building over two level, Type IA, basement parking garage. New 1200 A 208Y/120V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52595	16041-10001-34161	10250 W SANTA MONICA BLVD # 1750	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check only, changes to approved set, noted under Delta B3. Changes include relocation of the panels, transformer and HVAC in the kitchen; also, revise the load of panel 'M'.  Permit is covered under the master plan 16041-10000-34161	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52596	11041-10000-12403	936 S BARRACUDA ST BERTH 302-305	90731	15	018B201   298	7440026903		Harbor				2971.10	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	33.73774	-118.2636	NEW CONSTRUCTION FOR SHIP TO SHORE POWER AT BERTHS 302-305.  UNIT SUBSTATIONS ARE OVER 3 MVA AND ARE CHARGED UNDER PANEL BOARDS OVER 1200A, PLUGS TO SHIP (TOTAL OF 30) CHARGED AS NON-DWELLING POWER EQUIPMENT OVER 100.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52597	16041-10002-25486	407 N ARDMORE AVE	90004	13	138B193   162	5521023013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.07789	-118.30254	PLAN CHECK ONLY. CHANGES TO AN APPROVED SET. CHANGES TO THE SERVICE EQUIPMENT TO MATCH INSTALLED CONDITIONS. SWITCHBOARD INSTALLED GREATER THAN 600A. ALL CHANGES ARE MARKED UNDER DELTA 3. DELTA 2 CHANGES UNDER 16041-10001-25486 ARE NOT FOUND. DELTA 3 TO INCLUDE DELTA 2 PREVIOUS CHANGES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52598	17041-10000-00340	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	08/31/2020 12:00:00 AM	ADDRESS	34.16326	-118.37388	Full PC for power and energy. New mixed use housing complex -297 dwelling-unit 6 levels of apartment on top of on grade market (core and shell)  above 2 -level of type I construction parking garage.  Scope includes three new services/distribution boards(2500A & 1600A), new panels, new circuits, and new lights for two structures. Total affected area is 266331 Sq. Ft.  B#16010-10000-04268((((BUILDING COVERS TWO ADDRESSES:  5101 LANKERSHIM BLVD AND 5130 KLUMP AVE.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52599	11041-10000-12766	401 WORLD WAY parking	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/08/2011 12:00:00 AM	ADDRESS	33.94281	-118.40686	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52600	14041-20000-23862	21700 W OXNARD ST suite 860	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for energy only. TI for an office on 8th floor of high rise office building. New lighting incl. emergency. 2614sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52601	16041-10009-01886	700-800 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 41 ON PLANS. ADDITION OF CIRCUITS AND PANEL(S). UPDATED QUANTITY LIGHTING TO MATCH FLOOR PLANS .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52602	12041-10000-17130	845 S FIGUEROA ST	90017	9	129A207   195	5144022036	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.04698	-118.26234	Plan check power and energy for Smart & Final on the first level of an existing 5-story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52603	13041-10000-05270	10250 W CONSTELLATION BLVD 23RD FLOOR	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			PC Approved	03/05/2013 12:00:00 AM	ADDRESS	34.05735	-118.41746	PERMITS FOR TITLE 24 PLANS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER. PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN EXISTING OFFICE BUILDING IN A HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52604	15041-10000-33528	6255 W SUNSET BLVD 21 FLOOR	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	Energy plan check for corridor TI located in the 21th floor of a l high rise building. Scope of work includes  new light fixtures and receptacles.  total area 903-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52605	18041-20001-15077	7600 N BALBOA BLVD STE 109	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	08/14/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5 and 6. Changes have been to circuiting and feeders on the SLD.*****Previous Work Description*****T-24 PC, CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE OF WORK INCLUDES NEW PANELS, LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1776.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52606	19041-20001-41123	5505 N CALHOUN AVE	91401	4	174B153  1042	2245023013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM			PC Approved	11/06/2019 12:00:00 AM	ADDRESS	34.17036	-118.44231	11/6/19CHANGES TO APPROVED SET DELTA 1 ONLY.<<<PV roof mounted system, PV system size: 15.12KW with 42 PV Modules and 2 inverter(7.6KW), sub-panel and main panel PV ready.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52607	15041-10000-16218	21012 W STRATHERN ST	91304	3	189B105   174	2109010007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.21584	-118.59143	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION 15041-20000-13290	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52608	16041-20000-39269	8238 N SEPULVEDA PL	91402	6	192B145   470	2209001005	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM			PC Approved	11/04/2016 12:00:00 AM	ADDRESS	34.22083	-118.46605	pv1install roof mounted pv system sized 3.8kw interconnectedw ith msp.  standard plan.  This is plan check only.Permit fees paid under application number 15041-90000-20198	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52609	17041-10000-14052	5715 N FIGUEROA ST	90042	1	151-5A229 170	5492001015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.10994	-118.19246	PC FOR TI. TITLE 24 ENERGY ONLY FOR A COMM. BUILDING. TOTAL AFFECTED AREA OF 6284 SQ.FT.SCOPE INCLUDES NEW LIGHT AND RECEPTACLES.B# 16016-10000-27683TI FOR A RECORDING STUDIO (URM BUILDING) AT BASEMENT. NO CHANGE OF USE. ADD NONBEARING PARTITION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52610	14041-10001-30011	1740 W 62ND ST	90047	8	105B193   825	6002029017	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	33.98314	-118.30812	PV 2 ROOF MONTED SOLAR ARRAY, INTERCONNECT WITH MAN PANEL.  SYSTEM SIZE 3 KW WITH 12 MODULES WITH 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52611	08041-20008-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM			PC Approved	01/31/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to Previously approved set of plans.  Plan Check Only for DELTA #221 Only.<<<<NEW HIGH RISE BUILDING - MEDICAL OFFICE (SHELL ONLY)P/check is approved subject to the ""Conditions of Approval"" on a request for modification regarding campus style feeder to a fire pump.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52612	15041-30001-41383	8124 W 3RD ST	90048	5	138B173   960	5511029032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.0721	-118.36676	Plan check for Title-24 only.  Total area = 5,210 sq. ft.   T.I. to office space in existing commercial low rise building.  1 new subpanel + lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52613	19041-20000-47452	7674 N HATILLO AVE	91306	3	189B113  1302	2106011070	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.21028	-118.56511	PV1. INSTALL 3.96 KW DC GRID-TIED PV SYSTEM WITH (12) MODULES/MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52614	17041-10000-32471	8500 W BEVERLY BLVD Spc#646	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC for T24 only for new lights. Total area is 5540sqft. Installing two new panels and 75kVA transformer. RETAIL TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52615	19041-20000-39297												Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM				VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52616	11041-20000-06999	11755 W WILSHIRE BLVD #1400	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	PIN	34.04869377	-118.46238681	T.I. to existing high rise building.  Install general/emergency lighting on 14th floor of phase 2 as shown on plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52617	11041-10000-22524	100 W PACIFIC COAST HWY	90744	15	036B205  1125	7420007041	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	ADDRESS	33.79093	-118.26356	T.I. for an existing restaurant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  New load is less than 400A and occupancy load is less than 99.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52618	14041-20000-16749	1515 W 190TH ST suite 103	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.85852	-118.30531	Plan check for energy only. High rise office building, remodel of existing office on the first floor. All circuits are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52619	16041-10000-39102	9356 N LEMONA AVE admin bldg	91343	7	198B149   174	2650034019	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Closed	12/13/2018 12:00:00 AM	ADDRESS	34.24086	-118.45871	PC FOR POWER AND ENERGY. DEVELOPMENT OF A NEW PUBLIC CHARTER HIGH SCHOOL- CONSRUCTION OF ONE NEW ADMINSTRATION/MULTI-PURPOSE BLDG. PLAN CHECK AND FEES ARE UNDER 16041-10000-39098. B# 16010-10000-04639	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52620	13041-20000-05099	11620 W WILSHIRE BLVD ste 710	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	34.05021	-118.45963	full plan check for dental office. Suite #710. High-rise commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52621	16041-10000-45538	1601 E OLYMPIC BLVD #201	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.02923	-118.24056	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52622	12041-20000-27965	5140 W WASHINGTON BLVD	90016	10	126B181   939	5062006021	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Expired	12/16/2014 12:00:00 AM	ADDRESS	34.04097	-118.35231	New partition wall and exterior door opening with interior remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52623	15041-10000-32695	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Expired	10/30/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	New fire alarm system for an existing office tower at the bloc core and shell for renovations on street level through third, and additional devices on 20th, 32nd, and roof levels. Existing  devices with 190 new FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52624	19041-20000-50633	146 S AVENUE 53	90042	1	150A227   176	5468016011	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	07/06/2020 12:00:00 AM	ADDRESS	34.10552	-118.19765	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 8 KW DC/7.052 KW AC. SCOPE OF WORK CONSISTS OF (25) PV MODULES WITH MICROINVERTERS, AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52625	18041-10000-24132	10215 N CANOGA AVE	91311	12	204B105   421	2747010021	[T][Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.25564	-118.59748	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52626	14041-20000-14207	1250 W VALROSE CT	90041	14	162A229   199	5690007042	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.13781	-118.19428	PV1.  Install 5.0 kW roof-mounted utility-interactive PV system.  Transformerless inverter w/ power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52627	15041-20000-17399	6600 N TOPANGA CANYON BLVD 1058D	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is an existing tenant space withing the mall. Project scope is a tenant improvement. Total lighting area = 1,374 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52628	17041-10003-17169	3763 S WALL ST	90011	9	117A205   431	5121023003	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	Apartment			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.01319	-118.27108	PC FOR REVISION TO APPROVED SET. CHANGES INCLUDE CHANGES TO PANELS LOCATION PER INSPECTIONTHIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER MASTER PERMIT. Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system 4.8KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52629	12041-10001-30238	5857 S CENTRAL AVE	90001	9	108B209  1518	6007003902	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	((4/18/2014- CHANGES MADE TO APPROVED SET OF PLANS. RELOCATION OF EV CHARGER LOADS TO NEW SUBPANEL. LOAD CALCS TO BE VERIFIED. DELTA 10 CHANGES)))SHOP BUILDING (RETAIL) . PLAN CHECK FOR site lighting. (Title 24 requirements).  Also stubbing for future signage (outdoor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52630	16041-20000-21972	7944 N KEER DR	91335	12	189B125  1024	2102015097	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.2154	-118.53476	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52631	10041-20000-10281	300 W WORLD WAY Terminal 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/01/2010 12:00:00 AM			Permit Finaled	02/25/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check T-24 Energy for Continental Terminal 6 Arrival Level	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52632	16041-20001-04523	4641 N LIBBIT AVE	91436	5	168B137   565	2284001022	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.15463	-118.48875	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.7 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52633	18041-20000-04590	19144 W SALT LAKE PL	91326	12	210B121   341	2718004032	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.2718	-118.54971	Plan check for the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52634	14041-10000-08182	7007 W IMPERIAL HWY	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.93185	-118.41447	FA FOR AIR NEW ZEALAND.  1 story. B,S-1 fully sprinklered, III/B. 1 panel, 46 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52635	13041-10000-03834	4301 W AVENUE 42	90065	14	159A217   262	5684011025	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.12922	-118.22968	PV1  ROOF MOUNTED SOLAR INSTALLATION IN A SINGLE STORY HOME USING MICROINVETER STANDARD PLAN. INSTALLING 14 MODULES IN A SINGLE CIRCUIT. SYSTEM SIZE IS 3.024KW [INVETER: ENPHASE # M215-60-2LL-S22 |||| MODULES: REC # REC 245 PE]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52636	16041-10000-04411	127 E 73RD ST	90003	9	102B205   983	6022001022	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	33.97393	-118.27284	PV1, ROOF MOUNTED SYSTEM USING CENTRAL INVERTERS. (20) MODULES AND (1) 6KW INVERTER. TOTAL SIZE IS 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52637	10041-10000-21968	800 N ALAMEDA ST K1	90012	14	132A215    65	5409023054	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.05494	-118.23752	"TI IN AN EXISTING RETAIL AREA IN ""WETZEL'S PRETZELS"" IN SPACE # K1.   PLAN CHECK IS FOR T-24 ENERGY CALCS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52638	19041-10000-14383	600 W 7TH ST #425	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.04728	-118.25685	Full plan check for (E) 7-story office building, Suite #425. Scope include new lighting and equipment with a total area of 7,058 SQ FT.B# 19016-10000-11455	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52639	19041-20001-01443	245 N TOYOPA DR	90272	11	123B129   686	4411024027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM			PC Approved	04/11/2019 12:00:00 AM	ADDRESS	34.03161	-118.52	Revision to approved set.  Change of PV subpanel bus rating to 125A.  (((Installation of (2) Tesla battery back up (ESS) 5 kWh each to an existing PV system.  Plan check for power only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52640	14041-20001-05289	5454 N NORWICH AVE	91411	4	174B145   717	2250013036	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.17011	-118.46054	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52641	11041-10000-07322	3233 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035012	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	08/03/2011 12:00:00 AM	ADDRESS	34.02889	-118.37311	SPRINKLER MONITORING SYSTEM.    TWO STORY BUILDING.  INSTALLING ONE FIRE ALARM PANEL, 21 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52642	17041-10001-16855	4625 N ALGER ST	90039	13	159B205    22	5593021007	MR1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.13589	-118.26712	PC FOR WAREHOUSE AND OFFICE TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 9122 SQ.FT. (indoor and outdoor conditioned and not conditioned)MISSING OUTDOOR HARDSCAPE AREA. INSTALLING NEW LIGHTS AND RECEPTACLES.This is plan check only !!! 10 NEW CIRCUITS FOR AREA LIGHTING RESTROOMS GFI'S AND INSTANT HOT, 7 NEW EXIT SIGNS, REPLACE LIGHT FIXTURES 18 WAREHOUSE SIGNS, REPLACE LIGHT FIXTURES 18 WAREHOUSE AND LIGHTS IN FRONT OFFICES REPLACE RECEPT. REWIRE 2 EXISTING AC UNITS. 2 LIGHTS OUTSIDE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52643	15041-20000-20163	21255 W BURBANK BLVD	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.17432	-118.59446	TI to existing commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 1,750.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52644	18041-10000-30203	7265 W MELROSE AVE	90046	5	141B181   541	5525012013	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM			Verifications in Progress	09/06/2018 12:00:00 AM	ADDRESS	34.08365	-118.348	Energy plan check for a change of use from autopart repair store to restaurant tenant improvement; Scope includes new lighting and equiptment with a total area of 1,862-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52645	11041-10000-22187	828 E TRACTION AVE	90013	9	127-5A215 107	5163013006	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	34.04467	-118.23527	Per applicant, change of use to create a new bakery in a 3-level building.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52646	18041-20000-32378	10211 S CENTRAL AVE	90002	8	090B209   424	6049026004	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM			PC Info Complete	08/24/2018 12:00:00 AM	ADDRESS	33.94376	-118.25435	Plan check for Title 24 only in existing retail space T.I. Total area: 1023 sq ft. B#18041-10000-26917	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52647	15041-10002-29087	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Issued	11/14/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	09/14/16Changes to an approved set of plans. All changes are clouded under delta 4. Scope includes upgrading two transformers for emergency distribution boards(boards EDG-1 & EDB-A) to 45KVA transformers, replacing the EBLB panel with a new 100A panel, and revising panels schedules. (((((3/9/16: Changes to approved set under Delta-3: (1) Adding branch circuit to panel AA, AB, and GE    (2) install Temporary EM. lights to tenant space.   ***FULL PLAN CHECK FOR TENANT IMPROVEMENT; SCOPE INCLUDES ELECTRICAL WORK WITH NEW EQUIPMENT AND LIGHTING FROM LEVELS BASEMENT  THRU 2ND FL;  PLAN CHECK ONLY - PERMIT WAS PREVIOUSLY OBTAINED UNDER 14041-10000-09802 IN CONJUNCTION WITH APPROVED PLANS STAMPED BY PREVIOUS ENGINEER HIRED FOR PROJECT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52648	16041-10000-38452	201 S BROADWAY	90012	14	130-5A213  21	5149009019	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			PC Info Complete	11/01/2016 12:00:00 AM	ADDRESS	34.05237	-118.24698	Plan check for Title 24 only in existing space high-rise building T.I. Total area: 490 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52649	14041-10000-34533	12516 N MCLENNAN AVE	91344	12	219B133   379	2609025058	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	34.29723	-118.50138	PV1.  Install 8.83 kW roof-mounted, utility-interactive PV system.  (27) modules with (2) transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52650	19041-20000-22146	15301 W VENTURA BLVD Ste 330	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.15411	-118.46654	Existing commercial office remodel.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52651	19041-20000-50273	110 E 9TH ST 4th Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	04/10/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TI to commercial tenant spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52652	17041-20001-43252	9527 GLORY AVE	91042	7	198B201   186	2572039010	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	Yes	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	PIN	34.24086904	-118.28002593	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (23) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52653	17041-20003-44997	327 N CHESTNUT AVE	90042	14	153A233    90	5493031004	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	ADDRESS	34.11489	-118.1752	07-02-2018 Changes to an approved set of plan. Changes include remove battery back up system from project and sub-panel. PV System size 3.575kWFees $0 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52654	18041-10000-30259	8511 N FALLBROOK AVE 1ST FL	91304	12	192B097   585	2005022004	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.22466	-118.62773	TI IN AN EXISTING OFFICE AREA IN SUITE NUMBERS 120 & #140 (4105 SF). T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-19881	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52655	15041-10000-35057	9057 N NORRIS AVE	91352	6	195B173   106	2408036031	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Issued	10/20/2015 12:00:00 AM	ADDRESS	34.23333	-118.37727	T-24, TO AN (E) COMMERCIAL BUILDING. REMOVED HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 2944.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52656	17041-20000-40423	8745 N GOTHIC AVE	91343	12	195B137   683	2688038026	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Closed	04/07/2023 12:00:00 AM	ADDRESS	34.22978	-118.48969	pv1install roof mounted pv system sized 6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52657	13041-10000-00141	1500 E ANAHEIM ST	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			01/03/2013 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	33.78074	-118.24357	INSTALLATION OF NEW FIRE ALARM SYSTEM IN THE PACIFIC MARITIME ASSOCIATION., DISPATCH HALL BUILDING. 2 STORY BUILDING. 1 Fire alarm panel 59 Devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52658	15041-10001-15682	12180 W MILLENNIUM 5th Flr	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Expired	09/11/2017 12:00:00 AM	ADDRESS	33.97975	-118.40731	"Change to approved set by adding (3) equipment and (2) circuits to Panel ""5LD-B2"",  minor load changes have also being adjusted from the panel; All changes is under delta-7 only.(((Full plan check for first time tenant, office located at the 5th floor of a commercial building. Scope include new equipment, lighting and receptacles.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52659	13041-10000-21326	6555 W BARTON AVE WEST BDLG	90038	4	144B185  1067	5532014032	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.08785	-118.33475	NEW BUILDING, CORE & SHELL OFFICE , 5 STORIES BUILDING, 13760 SF, PC IS FOR POWER AND ENERGY. 1 PLAN WILL BE SUBMITTED FOR 3 BUILDINGS; THIS IS BUILDING # 3 OF 3,WEST BUILDING. SWITCHBOARD SECTIONS NEEDS TO BE CHARGED, ELEVATION DIAGRAM IS MISSING. LOCATION IS IN METHANE ZONE .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52660	18041-20000-37582	18215 W SYLVAN ST	91335	3	177B125  1035	2124018074	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.18535	-118.53013	PV1.  Install 11.65 kW AC CEC roof mounted grid tied PV system.  (39) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52661	17041-20000-05535	7220 W BEVERLY BLVD	90036	5	138B181   443	5512023002	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.07598	-118.34699	"New lighting and change of use from beauty shop to office.  Building permit filed under 17016-10000-00331.  Plan check for energy.  ""COMPLY WITH DEPARTMENT ORDER effective date11/17/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52662	17041-10000-02650	615 W 41ST PL	90037	9	114A201    28	5019019011	RD1.5-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.00794	-118.28465	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(20)MODULES- LG LG300N1K-G4 (20)ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52663	10041-20000-13704	1678 N ALTA MURA ROAD	90272	11	135B133   197	4425002020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2010 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	06/15/2012 12:00:00 AM	ADDRESS	34.06295	-118.50109	Plan check for new single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52664	15041-10000-05557	8705 S CROCKER ST	90003	9	096A205     8	6041017018	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Expired	03/22/2017 12:00:00 AM	ADDRESS	33.9589	-118.26823	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 4116 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52665	18041-10000-26025	12020 W CHANDLER BLVD 4TH FL	91607	2	171B165   200	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.16825	-118.39512	PC FOR OFFICE T.I,  ON THE 4TH FLOOR FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 1222.SCOPE INCLUDES NEW CIRCUITS, EQUIPMNET AND LIGHTS. B#18016-10000-19225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52666	14041-10001-08654	6940 ESTEPA DR	91042	7	198B201   177	2572042004	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	06/12/2014 12:00:00 AM	PIN	34.24095021	-118.28301165	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(18) MODULES: CANADIAN SOLAR CS6P-250PX}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52667	18041-10000-02609	740 S BROADWAY	90014	14	127-5A209 107	5144015023	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.04414	-118.25412	PC for T24 only for new lighting in kitchen an food prep area of theater. Installing new lights. b# 18016-10000-02288. Total area is 366sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52668	16041-10000-35333	1121 S WESTERN AVE	90006	10	129B193   752	5080003041	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM			PC Approved	10/05/2016 12:00:00 AM	ADDRESS	34.0501	-118.30928	Plan check Title 24 only in existing restaurant El Cholo T.I. in restroom.  Total area: 336 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52669	14041-10000-13430	903 S NEW HAMPSHIRE AVE 1-16	90006	10	132B197   836	5094025002	(T)(Q)R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			05/20/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.05572	-118.29316	PROPOSED 16 UNIT APARTMENT  W/ GARAGE.  4 STORY W/ MEZZ, TYPE IIIA CONSTRUCTION OVER TWO LEVELS (BASEMENT AND 1ST FLOOR)  OF TYPE I GARAGE.SPRINKLERS ARE BEING USE FOR AN INCREASE IN THE ALLOWABLE NUMBER OF LEVELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52670	12041-20000-20450	23211 W CALVERT ST	91367	3	177B093   436	2035023037	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.18144	-118.63203	Photovoltaiac system on roof of single family dwelling, using enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52671	14041-20000-04129	17737 W ALONZO PL PV1	91316	5	168B129   745	2182025012	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Expired	04/12/2016 12:00:00 AM	ADDRESS	34.15277	-118.51955	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 400A MAIN SERVICE PNL. UNGROUNDED SYSTEM, SIZED @ 9 kW DC, WITH (36) CANADIAN SOLAR #CS6P-250PX,  (36) OP300 OPTIMIZERS, (2) SOLAREDGE SE3800-US-ZB-U, (1) 125A LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52672	13041-10000-05529	6133 N TOPANGA CANYON BLVD	91367	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.18184	-118.60616	THIS APPLICATION IS FOR THE PERMANENT INSTALLATION OF ELECTRICAL EQUIPMENT. PC FOR POWER AND ENERGY. TEMPORARY POWER APPLICATION ALREADY SUBMITTED SEPERATLY. USE OF BUILDING, AUTO DEALERSHIP.RENOVATION OF AUTO DEALERSHIP. TWO PLANS HAVE BEEN SUBMITTED. ONE PLAN FOR TEMPORARY POWER FOR CONSTRUCTION UNDER THIS APPLICATION. ANOTHER FOR POWER AND ENERGY FOR INSTALLATION. THIS APPLICATION IS FOR TEMPORARY POWER FOR CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52673	13041-20000-34159	11601 W WILSHIRE BLVD #1825	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	Change to lighting in an existing high rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  NO Emergency lighting.  18th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52674	15041-20000-09946	1556 W 22ND ST	90007	8	123B197   137	5054023011	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Expired	07/20/2017 12:00:00 AM	ADDRESS	34.03622	-118.29347	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system with 16 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52675	14041-10000-17846	7315 N FIGUEROA ST # 102	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.13628	-118.18852	CHANGE OF USE AND T.I. FOR NEW RESTAURANT PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52676	12041-10000-23822	7901 N VENTURA CANYON AVE	91402	6	189B157   570	2214026025	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Public Safety Only			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	07/15/2013 12:00:00 AM	ADDRESS	34.21406	-118.42891	NEW FIRE WARNING SYSTEM FOR 3-STORIES 30 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52677	17041-20000-43350	19508-19516 W CARDIN PL	91324	12	198B117   258	2761035101	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.23751	-118.55832	new apartmernt building 600 amp service.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52678	15041-10000-11689	2272 W 29TH ST	90018	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.02896	-118.31691	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52679	18041-10000-00484	20200 W SUNBURST ST	91311	12	195B113    29	2781035007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.23439	-118.5736	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52680	13041-10001-30830	9617 S LA SALLE AVE	90047	8	093A195   244	6055019046	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	33.94805	-118.30587	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 3.5 KW.(14) TRINA SOLAR # TSM-250PA05.18(14) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52681	17041-10000-44927	11150 W SANTA MONICA BLVD 7TH FL	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	ALTERATIONS IN PUBLIC LOBBY AND RESTROOMS  OF OFFICES PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52682	17041-10000-06611	5757 W WILSHIRE BLVD #473	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	"Plan check for Title 24 only in existing space high-rise building office T.I. Total area:1,842 sq ft.  ""COMPLY WITH DEPARTMENT ORDER effective date 02/16/17. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52683	18041-10000-14793	8911-8917 N RESEDA BLVD	91324	12	195B125   400	2770005015	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Public Safety Only			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Issued	04/23/2018 12:00:00 AM	ADDRESS	34.23228	-118.53628	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 65 FA DEVICE, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52684	19041-20000-23613	350 S GRAND AVE STE 3560	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	T24 PLAN CHECK FOR TI TO A EXISTING HIGH RISE COMMERCIAL 35TH FLR STE 3560. LIGHTS ONLY. TOTAL SQUARE FOOTAGE =  2,118 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52685	19041-10000-11221	17081 W DEVONSHIRE ST BLDG C	91325	12	204B133    79	2695020030	[Q]C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	34.2577	-118.50558	(1 SET OF PLANS WITH 3 APPLICATIONS), 3 OF 3 PLAN CHECK FOR POWER AND ENERGY FOR NEW BLDG C, 3 STORY CLASSROOM BLDG. SCOPE INCLUDES NEW 1600A SERVICE. THIS IS THE MAIN BUILDING OF THE PROJECT. BUILDING C FEEDS BLDS A AND B.  REFFER TO THE PERMIT NUMBERS BELOW. B-A# 19010-10000-01179E-A# 19041-10000-11217B-B# 19010-10000-01180E-B# 19041-10000-11215B-C# 19010-10000-01182E-C# 19041-10000-112213 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52686	12041-20001-24338	15840 W MONTE ST 108	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/26/2012 12:00:00 AM	ADDRESS	34.31015	-118.47604	Plan check for power only. First-time tenant. Plan check for energy done on 12041-20000-24338.Plan check for energy and emergency lighting. Office space. Suite 108. VERIFICATION:  EMERGENCY LIGHTING REMOVED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52687	16041-20000-11007	314-326 S LINCOLN BLVD	90291	11	111B145   634	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.00118	-118.46712	PLANCHECK FOR T24 ENERGY( LIGHTING ONLY). TENANT IMPRVEMENT OF INTERIOR AND EXTERIOR. [INSPECTOR TO VERIFY LOAD < 400 AMPS FOR FULL PLANCHECK, NOT REQUIRED PER APPLICANT].BUILDING PERMIT # 15016-10000-26847 :SHELL AND CORE RENOVATIONS: EXTERIOR WALL ALTERATION; EXTERIOR FACADE RENOVATIONS; PARAPET EXTENSION; NEW CANOPY; NEW GLAZING AND STOREFRONT; RE-ROOF; (N) SKYLIGHTS; (SEE COMMENTS FOR ADDITIONAL SCOPE OF WORK)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52688	15041-20001-20542	11524 W HUSTON ST	91601	2	168B169   195	2354012002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	07/05/2015 12:00:00 AM	ADDRESS	34.15939	-118.38289	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Plan check is for the addition of a 3 kWac system onto an existing 4 kWac system. Total system size is 7 kWac. System consists of (1) inverter, (12) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52689	14041-20001-24880	7014 S HOOVER ST UNIT 3	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 3.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52690	12041-10000-21199	7135 N HAYVENHURST AVE	91406	6	183B137    90	2225004042	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Expired	12/31/2014 12:00:00 AM	ADDRESS	34.20027	-118.49257	INSTALL A NEW OPTIONAL  STANDYBY BACKUP 200KW GENERATOR, ATS, AND CIRCUITS IN THE BUILDING FOR METRO PCS. NO BATTERY BACK-UP EMERGENCY LIGHTING AND EXIT SIGNS IN SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52691	19041-20000-22198	22135 W ROSCOE BLVD LOT #22	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 22.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52692	11041-10000-16093	11348 W SUNBURST ST	91342	7	213B173   367	2530020035	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.04	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.27775	-118.37857	TI TO AN EXISTING 7-ELEVEN BUILDING.  REPLACEMENT OF EXISTING FIXTURES IN THE RETAIL AREA ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52693	17041-10000-04095	12777 W JEFFERSON BLVD #B 100	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	33.9778	-118.41768	Plan check for Title 24 only in existing building T.I. office space. Total area: 11,683 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52694	16041-20001-20723	7900 N BALBOA BLVD	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM			PC Approved	03/02/2017 12:00:00 AM	ADDRESS	34.21347	-118.50092	"[[[ 3/2/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. CHANGES ARE CLOUDED. ADDING PTAC UNIT TO 5 LARGE OFFICES, ADD TWO ADDITIONAL FIXTURES IN 2 SMALLER OFFICES, AND REPLACE HANGER LIGHTS FROM FLUORESCENT TO HIGH BAY LED]]]]Plan check for power and energy for Van Nuys Airport Building ""D"" (Delta) aircraft hangar. Service size: 800A. Total area: 32,845 sq ftBuilding Applicant #: 16010-30000-01587"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52695	15041-10001-44014	12733 N DARYL AVE	91344	12	222B129   309	2608001025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.3019	-118.51464	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 11550 WDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(66) MODULES:REC SOLR REC275TP(2) INVERTER: SOLAREDGE TECHNOLOGY SE 7600A-US 240V>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52696	15041-20000-15522	7824 N KENTLAND AVE	91304	12	189B101   610	2013011016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.21275	-118.61748	Plan check for PV roof mounted 6.7kW system with 27 modules and microinverters. Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52697	16041-10001-30277	636 S MARIPOSA AVE	90010	10	135B197  1222	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	PIN	34.06223337	-118.29881302	"09/01/16Changes to an approved set of plans. All changes are clouded under delta 1. no changes in lighting. Changes include adding an electric water heater on panel ""A"" and on the floor plans. Note: Original application is under PCIS#16041-10000-30277(((((((((((CHANGE OF USE FROM EXISITING OFFICE TO  ART GALLERY WITH BAR (1402SQFT). (original application was for art gallery)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52698	16041-20000-23889	1880 S CENTURY PARK EAST 5TH FLOOR	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.06144	-118.41437	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOM AND ELEVATOR LOBBY. 5TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52699	11041-10000-26658	2501 N ZORADA DR	90046	4	153B177   261	5569021060	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.11687	-118.36138	PLAN CHECK TWO STORY SINGLE FAMILY DWELLING WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52700	14041-20001-28696	18935 W COVELLO ST	91335	3	186B121   235	2104014018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM			PC Approved	11/07/2014 12:00:00 AM	ADDRESS	34.20759	-118.54618	Modification to approved pv plan set. Change string configuration (from 6+6 to 4+8). Relocate 2 panels on roof. Change location of service equipment. Change main service panel from 100A to 200A. See Delta 1 changes.[PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING TOTAL OF 12 MODULES.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52701	18041-20000-17688	11601 W WILSHIRE BLVD STE 460	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	TI to (E) commercial office space in highrise building.  Plan check for energy - 2475 sq ft.(((TI WORK ON +/- 2475 SF OF THE TOTAL FLOOR AREA. NEW NON-LOAD BEARING NON-RATED INTERIOR PARTITIONS, POWER, LIGHTING, AND FINISHES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52702	17041-10000-23627	515 S COLUMBIA AVE	90017	1	132A207    86	5153020001	PF-1XL	Central	Westlake	Westlake North		2091.02	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Issued	07/13/2017 12:00:00 AM	ADDRESS	34.05667	-118.26617	PC FOR FA SYSTEM. TI, NEW PANEL AND 124 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52703	17041-20000-12453	"7900 N BALBOA BLVD BLDG ""C"""	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	"PLANCHECK FOR POWER AND ENERGY. NEW SERVICE. NEW AIRCRAFT HANGAR ARTICLE 513 SPECIAL OCCUPANCY, BLDG ""C"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52704	10041-10000-08897	900 N ALAMEDA ST 2ND FLOOR	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	12/02/2010 12:00:00 AM	ADDRESS	34.05855	-118.23671	TI IN AN EXISTING COMERCIAL AREA ON THE 2ND FLOOR. INSTALL A 2MVA STEPDOWN (4160:480) TRANSFORMER, UPS'S, PANELS & LOAD TO A COMPUTER ROOM. PLAN CHECK IS FOR POWER, ENERGY & EMERGENCY LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52705	17041-20000-10669	14921 W CALVERT ST	91411	6	178-5A149 316	2242024049	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.18133	-118.45821	service upgrade to an existing commercial building 1200 amps with new panels.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52706	19041-20000-00915	13287 N RALSTON AVE	91342	7	225B141  1540	2501002069	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	34.31289	-118.47324	New 250 kW emergency generator and associated distribution for industrial facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52707	19041-10000-09578	8740 S SEPULVEDA BLVD 1-11	90045	11	096B165   900	4123002005	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM			Reviewed by Supervisor	07/02/2019 12:00:00 AM	ADDRESS	33.95762	-118.39595	Full PC for power and energy. Change of use from office to retail & addition at mezz level. Scope includes a new 800A Service/Distribution boards, new circuits and lights. Total affected area is 6254.4 Sq. Ft.  B#19014-30000-01250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52708	17041-20001-39776	5309 N ALHAMA DR	91364	3			R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM			PC Approved	11/04/2017 12:00:00 AM	ADDRESS	34.16566	-118.59398	expeditepv1install roof mounted pv system sized 3.8kw interconnected with msp.this is system (2) of a two part system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52709	16041-10004-08351	524 E WASHINGTON BLVD	90015	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Info Complete	06/28/2017 12:00:00 AM	ADDRESS	34.0283	-118.25963	CHANGE TO APPROVED SET OF PLANS. CHANGE NOTED DELTA 5 ON PLANS. CHANGE TO INTERCONNECTION TO EXISTING SERVICE IS NOW LINE SIDE TAP.2000 switch gear under seperate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52710	12041-10000-13612	4301 W 3RD ST	90004	4	135B193   200	5517007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	05/03/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	PIN	34.06916769	-118.30825671	PLAN CHECK POWER AND ENERGY FOR NEW 2 STORY YMCA BUILDING WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52711	19041-10000-10635	111 N HOPE ST	90012	14	133-5A211 168	5161003910	PF-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.05807	-118.24862	INSTALLING (1) LITIUM BATTERY AND (15) FLOW BATTERIES FOR TOTAL OF 100KW FOR 1 YEAR PILOT PROGRAM. BLD# 19020-10000-00395	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52712	10041-10001-05484	1241 N VINE ST	90038	13	144B185   204	5533005001	C2-1D, RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM			PC Approved	07/13/2010 12:00:00 AM	ADDRESS	34.09373	-118.32682	Changes to the approved  plans. TITLE 24 AND EMERGENCY LIGHTING , NO HIGH RISE , COFFEE SHOP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52713	19041-10000-15271	4343 N LANKERSHIM BLVD 3rd Fl	91602	4	165B177   566	2423019075	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	07/25/2021 12:00:00 AM	ADDRESS	34.14909	-118.36531	INTERIOR TI AT THE THIRD FLOOR OF EXISTING MEDICAL OFFICE BUILDING. IMPROVEMENT FOR IMAGING MEDICAL CLINIC - MRI, CT SCANNER, MAMMOGRAPHY, ULTRASOUND AND ROOF TOP EQUIPMENT.  SCOPE OF WORK INCLUDES NEW 1600AMPS 480/277 3PH SWITCH BOARD CONNECTED TO EXISTING 3000A SERVICE , CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL AFFECTED AREA 10640 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52714	19041-10000-08658	338 E 111TH ST	90061	8	088-5A205 287	6073019007	R2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	33.9347	-118.26815	Plan check for a 3.8KW AC / 2.3KW CEC AC / 2.5KW DC pv system with (9) modules, (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52715	17041-10000-11435	189 S THE GROVE DR O-10	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Info Complete	05/16/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC for outdoor Title-24. New lighting and power for a new canopy for an outdoor bar. Area: 382.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52716	17041-10000-09747	5950 W COLGATE AVE GARAGE # 4	90036	4	135B181   159	5509005008	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.06917	-118.35267	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 55300 SQ. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52717	19041-20000-15079	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	06/16/2021 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial space.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52718	14041-20000-15485	17438 W HORACE ST	91344	12	210B129   684	2712015019	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Expired	05/08/2017 12:00:00 AM	ADDRESS	34.26955	-118.51448	PV1.  Install roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52719	12041-10000-09373	325 S LOS ANGELES ST	90013	9	129A213   143	5148001016	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.04807	-118.24551	T.I. to an existing Retail space.  Change to lighting, receptacles and circuits.  Load is 100A, per applicant.  PLAN CHECK  for Energy, with Emergency lighting.   Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52720	14041-20001-14624	7301 N DARNOCH WAY	91307	12	186B089   633	2027020022	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.20329	-118.64469	Expedite per customer request7.5KW roof-mounted system with (30) Canadian Solar modules( CS6P-250PX) , (30) Solaredge Powerbox Optimizer and (1) Solaredge transformerless inverter (#SE6000A-US).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52721	19041-10000-06894	5800 W SUNSET BLVD	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	34.09728	-118.31693	pc t-24 to TI. area  918 sqft. all secondary 24V class 1 circuits must be installd in an approved raceway (including LED strips)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52722	09041-10002-15382	8050 W 3RD ST	90048	5	138B177   753	5511028012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM			PC Approved	03/04/2010 12:00:00 AM	ADDRESS	34.07194	-118.36552	CHANGES TO APPROVED SET OF PLANS - REMOVE  SUBPANEL B AND REFEED ITS LOADS FROM PANEL A; REMOVE TRACK LIGHTING; RELOCATE REST ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52723	13041-10000-25203	21031 W VENTURA BLVD 12th flr	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	PIN	34.16717222	-118.59179488	TITLE-24 ONLY TENANT IMPROVEMENT IN A HISE-RISE ; EMERGENCY LIGHTS FED VIA EXISTING EMERGENCY CKT BY BUILDING GENERATOR. WORK IS DONE ON THE 12TH FLOOR. PERMIT ALREADY PULLED IN PLAN CHECK # 13041-90000-25041	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52724	17041-10001-34298	127 E 9TH ST	90015	14	126A211    33	5145014002	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.04104	-118.25421	REVISIONS TO PERMITTED SET OF PLANS CT UNITS CHANGED FROM TWO FANS TO ONE FAN EACH; ADDED THREE SP UNITS AND 1 EA CMP UNIT((((((PC for power for new roofmounted HVAC and chiller equipment. Load over 400A. Installing two new distribution panels on (E) build.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52725	12041-10000-23342	116 N KINGS ROAD 1-21	90048	5	138B173   556	5511010020	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			10/01/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.075	-118.37199	PLAN CHECK NEW FIRE ALARM SYSTEM FOR A 4 STORY, 21 UNIT APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52726	12041-10000-20610	20525 W NORDHOFF ST	91311	12	195B109    13	2748001037	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03, 1134.21	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.2322	-118.58093	1139.04 kw roof mounted pv system for a commercial Bildg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52727	12041-10000-05430	1048-1058 S DOREEN PL	90291	11	111B149   684	4243002068	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			03/09/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99968	-118.45883	Lincoln place apartments, two story , new fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52728	18041-10001-44005	110 E 9TH ST BLD. C	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	01/07/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	"DELTA 3, 4 AND 5 CHANGES TO APPROVED SET. DETAILED NARRATIVES ARE PROVIDED FOR EACH DELTA SEPARATLY. CHANGES TO POWE AND ENERGY WHICH INCLUDES DOWNSIZING TENANT TRANSFORMERS AND UPDATING ASSOCIATED WIRING AND EQUIPMENT ACCORDINGLY. SCOPE ALSO INCLUDE MECHANICAL AND EMERGENCY POWER UPDATES.ALL CHANGES ARE CLOUDED   ORIGINAL PLAN CHECK: FULL PLAN CHECK FOR POWER AND ENERGY (CORE & SHELL) IN AN EXISTING 14 STORY HI RISE BUILDING ""C"".   3 NEW 277/480 SERVICES (4000A + 2500A + 1600A), AREA APPROX. 583,018 SQR FT.  BUILDING PERMIT:"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52729	14041-10000-13784	5222 N SALOMA AVE	91411	4	172-5A149 254	2250021015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.16558	-118.45841	Install roof mounted solar pannels.System size = 8 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52730	18041-10001-28141	777 S SANTA FE AVE	90021	14	124-5A217 323	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	03/15/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	PC for delta 5 change only.y. CHANGES TO LUMINAIRES AND NEW CIRCUITS; NO INCREASES TO LIGHTING DENSITY;original electrical # 18041-10000-28141ORIGINAL PROJECT DESCRIPTION: FULL PLAN CHECK FOR TENANT IMPROVEMENT TO 1ST AND 2ND FLOORS OF OFFICE/ SPACE; INSTALL NEW PANELS, CIRCUITRY, LIGHTING AND POWER. TOTAL AREA UNDER THE SOW: 30,995 SQ.FTB# 18016-10000-22178	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52731	13041-20000-22372	13923 W VAN NUYS BLVD	91331	6	204B153   446	2617003034	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.2561	-118.43622	TI TO EXISTING MIX USE. NEW SUBWAY. PC FOR T24 ENERGY ONLY. TOTAL AREA 1295 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52732	18041-20000-06814	515 S FLOWER ST 32nd Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 only. Project site are the common areas and the restrooms of the 32nd floor of an existing high-rise building. Project scope is a tenant improvement. Total lighting area = 2,973 sq. ft.Note: Building permit has been issued under 17016-10000-34022	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52733	12041-10000-07965	6850 N WHITAKER AVE	91406	6	183B137   403	2225014018	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.19524	-118.49778	Roof mounted PV System on roof of single family residence using Enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52734	19041-10000-46159	660 N OXFORD AVE	90029	13	141B193   630	5521003051	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1925.10	Electrical	Electrical	Apartment			11/08/2019 12:00:00 AM	03/12/2020 12:00:00 AM		Permit Finaled	12/08/2021 12:00:00 AM	PIN	34.08322818	-118.30766577	FULL PC FOR A NEW 1600A SERVICE (208/120, 3P,4W), THAT FEEDS A 1600 MAIN SWITCHBOARD WHICH SUBFEEDS 42 SUBPANELS RATED AT 125A, TOTAL AFFECTED AREA IS 11,528 SQFT. PER BULDING((NEW 42 UNIT APARTMENT BUILDING 5 STORY (TYPE III-A) RESIDENTIAL UNITS OVER 1 LEVEL OF TYPE I-A RESIDENTIAL UNITS OVER 1 LEVEL OF TYPE I-A COMMUNITY ROOM  ( 5 EXTREMELY LOW INCOME AFFORDABLE HOUSING UNITS)B#19010-10000-01602))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52735	19041-10000-15778	6951 N LENNOX AVE	91405	6	183B149   423	2217010048	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Issued	04/30/2019 12:00:00 AM	ADDRESS	34.19703	-118.44562	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52736	17041-10000-17900	4224 E MERCURY AVE	90032	14	142-5A227 173	5305027028	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	1991.10	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2017 12:00:00 AM	05/30/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.08519	-118.19491	PV1 roof mounted solar system on single family home. New central inverter rated at 3.8 KW and 17 solar modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52737	16041-30000-00489	8735 N WHITE OAK AVE	91325	12	195B129   362	2768012010	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.22967	-118.52026	Addition of roof mounted solar PV array to existing roof mounted solar PV system.  Total system size = 9 kWac (5 kWac new + 4 kWac existing).  Two inverters total.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52738	19041-10000-00575	905 S VERMONT AVE	90006	10	132B197   834	5094026002	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	06/22/2020 12:00:00 AM		Issued	06/22/2020 12:00:00 AM	ADDRESS	34.05569	-118.29192	FULL PLAN CHECK FOR POWER AND ENERGY FOR - NEW 7 STORY MIXED USE HIGH RISE  BUIDLING WITH 67 UNITS.  NEW 2000A SERVICE 120/208V 3 PHASE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52739	18041-20000-17251	3456 W OLYMPIC BLVD	90019	10	129B189   255	5081026036	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	03/21/2021 12:00:00 AM	ADDRESS	34.05232	-118.31379	Plan check for power and energy. Project site is a new 2-story mixed-use building with basement parking garage. Building consists of (3) offices, (2) of which are medical offices, and (2) dwelling units. Work includes an 800 service and a total lighting area of 23,191 sq. ft.Note: Building permit has been issued under 18010-10000-01047	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52740	15041-10000-38825	1555 W SEPULVEDA BLVD A;B;C	90501	15	045B193   500	7347017068	M2-1VL, [Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	33.81603	-118.30485	ALTERATIONS IN EXISTING CAFE SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52741	19041-10000-14314	19450 W BUSINESS CENTER DR	91324	12	195B117    70	2783025068	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Issued	04/19/2019 12:00:00 AM	ADDRESS	34.2313	-118.55749	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52742	17041-20000-30960	24008 W SCHOENBORN ST	91304	12	192B089   147	2017037015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.22101	-118.64926	PV1.  Install 8.54 kW roof mounted grid tied PV system.  (28) modules with 7.6 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52743	10041-20000-08133	701 W EXPOSITION BLVD	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM			PC Info Complete	05/03/2010 12:00:00 AM	ADDRESS	34.01842	-118.2857	Plan check T-24 Energy (general/emergency) lighting for office TI in Hoffman Hall Suite #103, 300 at USC. New application under #10041-20000-10156	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52744	17041-10000-29843	3053 W LOS FELIZ BLVD	90039	13	157-5A207 162	5594028036	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.12509	-118.26595	REPLACE LIGHTING FOR LED TYPE. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52745	12041-10001-15683	5838 W GREGORY AVE	90038	13	141B189    64	5534031007	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Apartment			09/04/2012 12:00:00 AM	09/04/2012 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.08609	-118.32353	Revision to the approved plan. Plan check for fire sprinkler monitoring system. 7 unit apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52746	13041-10000-29928	17200 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Expired	01/29/2016 12:00:00 AM	ADDRESS	34.20827	-118.50773	PLAN CHECK FOR POWER AND ENERGY. PHASE 2 :TENANT IMPROVEMENTS AND EXPANSION OF CHASE BANK. 3 TOTAL PHASES.  PHASE 2: ADDING PANEL 3.  ENERGY BEING CHARGED IN PHASE 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52747	18041-20001-39895	2807 N NICHOLS CANYON ROAD	90046	4	156B177   709	5570033055	RE11-1	South Valley	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM			PC Approved	10/20/2018 12:00:00 AM	ADDRESS	34.1207	-118.35909	expeditepv1install roof mounted pv system sized 16.6KW AC interconnected with msp.  (4) tesla battery banks 5KW each	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52748	17041-20001-24809	17607 W BURBANK BLVD	91316	5	174B129   779	2254014011	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.17242	-118.51653	08/03/2017 Changes to an approved PV standard plan. Changes have been made to reflect existing distribution equipment ratings. *****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52749	16041-10000-02393	4119 W DUNDEE DR	90027	4	154-5A201  35	5592017030	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.11851	-118.2833	PV1 SFD TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM WITH POWR OPTIMIZERS. TOTAL OF 28 MODULES IN TOTAL. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52750	14041-10001-10190	837 N KODAK DR	90026	13	142-5A201 224	5427020002	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.08408	-118.28027	Expedited RSES plan check per applicant request.{{ Install 5.25 kW DC roof-mounted solar array on a two-story house, interconnect with  main service panel. (1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U. (21) Modules: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52751	15041-10000-13206	13231 W LOUVRE ST	91331	7	210B157   171	2534003018	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.27353	-118.42124	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES,, TOTAL AREA 11436 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52752	19041-20000-16979	24014 W GILMORE ST	91307	12	180B089   917	2033012003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.18654	-118.64894	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM FOR EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK INCLUDES 1 13.5 KWH TESLA POWERWALL BATTERY AND A 125A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52753	18041-20000-04832	1840 S CENTURY PARK EAST 4th flr-suite 440	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.06188	-118.41473	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52754	13041-10000-06847	1302 W 177TH ST BLDG C	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	PLAN CHECK FOR POWER AND ENERGY FOR A NEW 14-UNIT APARTMENT BUILDING (BUILDING C). MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52755	13041-20001-21990	1673 W 251ST ST	90710	15									Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	33.79689	-118.30671	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM WITH DC COMBINER. TOTAL SYSTEM SIZE 8KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52756	18041-10000-11497	1782 N ORANGE DR	90028	13	150B181   645	5548004010	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.10395	-118.34162	NEW SINGLE STORY OFFICE BUIDLING  2870 SF WHICH IS SUPPLIED BY A FEEDER FROM AN EXISTING SWITCHBOARD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52757	14041-10000-21621	4501 W COLORADO BLVD B8-2ND FLR	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.14246	-118.2705	PLANCHECKF FOR POWER AND ENERGY. TENANT IMPROVEMENT .  ADDING 3 NEW PUMPS FOR BLOOD TANK. HAZARDOUS LOCATION. CLASS DIV 2. INSTALL NEW VERTICAL MATERIAL LIFT. BUILDING P# 14016-10000-12718.(2008 T24 COMPLIANCE).  SEE APPL. COMMENTS...	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52758	10041-20000-17824	5817-5835 N FIGUEROA ST	90042	1	151-5A229  93	5492012024	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.10	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.11051	-118.19129	Plan check power and energy for TI of Dollar Tree. Existing 800A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52759	11041-10002-25989	189 S THE GROVE DR STE C-10	90036	4	138B177  1132	5512003042	C1.5-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.07125	-118.35662	revised permitted set of plans to reflect AS-BUILT conditionsRESTAURANT TENANT IMPROVEMENT WITHIN EXISTING LEASE SPACE; CHANGE OF USE; PROJECT INCLUDES AN EXTERIOR DINING PATIO  ( 3566 SF)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52760	09041-10002-24136	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005019	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM			PC Approved	04/04/2012 12:00:00 AM	ADDRESS	34.15303	-118.39667	SMALL CHANGES TO PERMITTED SET OF PLANS- ADDED A FEW RECEPTACLES AND CIRCUITS; ROOM 212 SUBDIVIDED INTO 3 EA OFFICES; LANDSCAPE LIGHTING ADDED;ATTACHED TO THE PLANS IS A LIST OF THE CHANGES AND THE PAGES ASSOCIATED WITH THE CHANGES.CHANGES TO PERMITTED SET OF PLANS: ADDED 80KVA UPS, AND CRAC UNITS FOR NEW ITE ROOM. DISTRIBUTION BOARD WAS UPGRADED FROMM 600A TO 800A. LIGHTING FIXTURES REMAINED THE SAME(((((((((NEW  PRIVATE SCHOOL BUILDING ; VARIANCE WAS FILED TO SEPARATE THE FA PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52761	12041-20000-02627	6960 N VESPER AVE Bldg.B	91405	6	183B149   391	2219026001	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Apartment			02/03/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.19734	-118.45077	New 3 unit apartment building.  Everything is new.  Full plan check.Request for Modification to separate Fire Alarm system filed 02.03.12	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52762	14041-20000-26521	9814 S FIGUEROA ST	90003	8	093A201   381	6054031037	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	33.94682	-118.28245	TI FOR AN EXISTING COMMERCIAL ONE STORY BUILDING.  NEW LIGHTING USING EXISTING EQUIPMENT POWER EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52763	15041-30001-22907	535 E VICTORIA AVE	90291	11	108B145  1755	4237003028	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	33.98906	-118.45895	Plan check for Title 24 only in exising space T.I. Total inddor and outdoor area: 5,661 sq ft. {{{{{NEW 400 AMP,  (2) 200 AMPS SUB-PANELS (2) 60 AMP HVAC UNITS , AND 8 BRANCH CIRCUITS.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52764	13041-10000-36327	2041 W BEVERLY BLVD	90026	13	136-5A205 336	5157021001	C2-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	PIN	34.0668634	-118.26993785	PLAN CHECK FOR POWER AND ENERGY, TI. UPGRADING 400 AMP SERVICE TO A NEW 800 AMP SERVICE.RETAIL STORE.ADDING 3 NEW PANELS.building description 13010.10.02216: NEW 2 STORY RETAIL  BUILDING (6500 SQ FT) WITH IN  THE  GAS STATION: BEER AND WINE SALE AND OFF SITE CONSUMPTION PER ZA 2011-3243 (CUB)(CU) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52765	19041-10001-22748	584 E AVENUE 28	90031	1	142-5A225 213	5206018004	[Q]R2-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.0827	-118.20563	Plan check for a 5.6KW DC / 3.8KW AC roof mounted system connecting through the load center along with the existing PV system. Scope includes (16) module and a load center interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52766	13041-10001-13166	21411 W PRAIRIE ST	91311	12	198B105    80	2746014003	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.2392	-118.59803	changes to approved plans:  Electrical/HVAC Changes Some equipment loads decreased and circuiting diagrams have to be revised. There was a discrepancy between the architectural and electrical lighting layouts. HVAC - Revised load calculations indicate that two (2) HVAC units (AC-1A and AC-1C) can be eliminated due to decrease in electrical heat loads. Two units will be removed along with associated ductwork. Increase in load for granulation rooms and decrease in load for mixing rooms. 3 pieces of equipment added to HEQ2 [sheets 0.2,0.3,0.4,2.1,2.1p,2.2,2.3]original description: pc for power and energy. 3 new panels: HEQ1/HEQ2/ACD and corresponding equipment for restrooms, granulation room, blending room. maintenance office/room, and processing line powder filling & packing. TENANT IMPROVEMENT OF EXISTING SUPPLEMENT PROCSSING PLANT AND WAREHOUSE:  DEMOLISH SOME EXISTING PARTITIONS, DEMOLISH EXISTING MULTIPLE ACCOMMODATION RESTROOMS AND RELOCATE (RECONSTRUCT), RECONFIGURE SOME PARTITIONED AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52767	17041-10001-34806	10635 W SANTA MONICA BLVD #350	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM			PC Info Complete	12/15/2017 12:00:00 AM	ADDRESS	34.05353	-118.43031	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include relocating/removing/replacing lighting fixtures on the floor plans, adding new receptacles, and revising title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52768	16041-20000-08561	18133 W VENTURA BLVD 3RD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM			Verifications in Progress	04/21/2016 12:00:00 AM	ADDRESS	34.16603	-118.52861	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. 3RD FLOOR OF A 4-STORY MED BUILDING. Medical outpatient (Oncology) center. 26,497sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52769	19041-20000-50749	14930 W VICTORY BLVD	91411	6	180B149   863	2242017021	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Apartment			12/13/2019 12:00:00 AM	08/02/2022 12:00:00 AM		Issued	08/02/2022 12:00:00 AM	ADDRESS	34.18642	-118.45854	FULL PLAN CHECK FOR NEW 800A SERVICE, (1) 800A MAIN PANEL, (12) 0-200A SUB PANELS, (1) 5.1-20 HP-KVA EQUIPMENT, (23) 3.1-5 HP-KVA EQUIPMENTS, (11) SMOKE DETECTORS, AND (173) BRANCH CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52770	14041-10000-28433	145 N LA BREA AVE UNIT B	90036	5	138B181   632	5513002010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.07488	-118.34438	PC FOR POWER AND ENERGY. CHANGE OF USE FOR A RESTURANT. TOTAL AREA  2587 SQ FT. FEES PER APPLICANT CALCULATION.(PER SHAUN )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52771	17041-10000-43247	662 S KELTON AVE	90024	5	135B149   483	4363014009	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	09/02/2020 12:00:00 AM	ADDRESS	34.06503	-118.45264	PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. SCOPE INCLUDES A 72 FA DEVICES AND ONE 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52772	17041-10000-01462	5340 S ALLA ROAD 111	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	33.9773	-118.42567	PC FOR ENERGY. TI OF EXISTING OFFICE SPACE, CHANGE OF A PORTION OF BUILDING FROM OFFICE TO STUDIO. CONNECTED LOAD < 400A, TOTAL AREA 23622 SQ FT. CORE $ SHELL UNDER SEPRATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52773	10041-10000-02919	11755 W WILSHIRE BLVD Suite#1200	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	07/30/2010 12:00:00 AM	PIN	34.04869377	-118.46238681	TI in an existing office area in suite # 1200. plan check is for power, energy & emergency lights, existing Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52774	13041-10000-29717	1108 N TAMARIND AVE	90038	13	144B189   645	5534010011	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.09102	-118.3189	TENANT IMPROVEMENT TO (E) ART STUDIO; TITLE 24 PART 6 ENERGY, LIGHTING FOR A 2-STORY STUDIO COMMERCIAL BUILDING. SCOPE OF WORK IS LESS THAN 400A .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52775	17041-20000-09879	12601 W PIERCE ST BLDG 5, 6	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for a PV2 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (41) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52776	15041-10000-02355	4433 S ALAMEDA ST	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM			PC Approved	01/26/2015 12:00:00 AM	ADDRESS	34.00295	-118.23924	Plan check for T-24 only. Total area: 682SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52777	10041-10000-23446	6330 W SAN VICENTE BLVD # 400	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	01/13/2011 12:00:00 AM	ADDRESS	34.06116	-118.36804	TENANT IMPROVEMENT IN OFFICE SPACESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52778	18041-10000-01209	10010 S INTERNATIONAL ROAD	90045	11	090B169    33	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	33.94517	-118.38136	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52779	15041-10000-41756	380 WORLD WAY T08	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	FULL PC, TI TO A RESTAURANT IN LAX TOM BRADLEY, NEW PANELS, LIGHTING AND RECEPTACLES. TOTAL CONNECTED LOAD > 400AMPS. TOTAL SQ. FT. 1906.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52780	18041-10001-26255	1302 S LA BREA AVE	90019	10	129B181   660	5070001036	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM			PC Approved	08/02/2019 12:00:00 AM	ADDRESS	34.04983	-118.34395	"change to an approved set, change under delta 1 which include energy and power changes. original plan checker ""kumar""B# 18016-10000-21119"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52781	16041-20001-26775	327 S HOOVER ST 1-48	90020	13	136-5A201 207	5501022007	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.06799	-118.2845	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 40kW with 176 modules and 4 inverters(10.0kW) connected to MSP}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52782	10041-10000-09988	834 W 28TH ST	90007	8	121-5A201  88	5123004402	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Public Safety Only			05/26/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	ADDRESS	34.02813	-118.28222	REPLACE FA panel and some FA devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52783	11041-10000-24398	6022 W AVION DR	90045	11	090B165    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	33.94182	-118.39269	New restaurant at LAX Terminal C, Space C1.  First time tenant, with new panel, circuits, and equipment.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52784	15041-10000-40809	5231 N MOUNT HELENA AVE	90041	14	163-5A227 163	5691006039	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Issued	01/13/2016 12:00:00 AM	ADDRESS	34.1426	-118.19593	PV1, Install 14.05 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (2)INVERTER: SMA SB7700TL-US-22 & SB5000TL-US-22. (43) modules SUNPOWER SPR327NE-WHT-D	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52785	19041-10000-44605	16040 W SHERMAN WAY	91406	6	183B141   128	2224004017	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	12/14/2020 12:00:00 AM		Permit Finaled	05/03/2022 12:00:00 AM	ADDRESS	34.20094	-118.48305	FULL PC FOR A NEW SERVICE 1600A (277/480), THAT FEEDS THREE DISTRIBUTION BOARDS, TWO AT 1600A AND ONE AT 800A. THESE DISTRIBUTION BOARDS FEED VARIOUS SUBPANELS AND OTHER ASSOCIATED EQUIPMENT. TOTAL AFFECTED AREA IS 159,357 SQFT. PER BULDING((CHANGE OF USE FROM RETAIL TO MARKET AND ADDITION (35718 SF) TOTAL FLOOR AREA OR REMODEL + ADDITION IS 43845. UPGRADE /REDSIGN ENTIRE ____________ FOR LATERAL AND FOUNDATION SYSTEM.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52786	10041-20000-16032	3494 E PICO BLVD	90023	14	118-5A225 320	5190036804	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.0179	-118.20314	revision to approved plans delta 4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52787	11041-20000-05551	6301 N OWENSMOUTH AVE 8TH FL	91367	3	177B105   123	2146029016	WC	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/21/2011 12:00:00 AM	ADDRESS	34.18467	-118.60176	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT 8TH FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52788	14041-20000-20982	10502 N WILLOWBRAE AVE	91311	12	207B105   608	2722034006	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.26108	-118.59879	PV1.  Install 4.52 kW roof-mounted, utility-interactive PV system.  Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52789	19041-20000-50701	11601 W WILSHIRE BLVD Suite 1820	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Issued	12/10/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only, for new lighting. Total area: 44 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52790	19041-10000-25903	519 E 7TH ST	90014	14	126A213    56	5148025024	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			07/08/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	08/17/2021 12:00:00 AM	ADDRESS	34.04093	-118.24682	Fire alarm PC for New 5-story  apartment  over 2 levels of  parking garage ( total 7 story building). 1 FACP and 253 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52791	15041-20000-24473	6220 N TOPANGA CANYON BLVD #9030	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.1841	-118.60553	Plan check for power and lighting. Project site is an existing commercial building. Project scope is a first time tenant at the Westfield Village. Total lighting area = 226 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52792	11041-10000-14359	240 E 6TH ST	90014	9	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			07/14/2011 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.0435	-118.24761	USING A COMMERCIAL BUILDING ,ADDING STATE-CERTIFIED PREFABRICATED UNITS TO PROVIDE TEMPORARY SHELTER FOR HOMELESS PEOPLE.THIS IS NOT AN APARTMENT BUILDING- IT IS MORE LIKE A HOTEL/SHELTER.REVISION WERE MADE AND REVIEWED ON 11041-10002-14359 IS ASBUILT SET	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52793	16041-10000-06153	5907 S WILTON PL	90047	8	105B189   195	6001007018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	33.98708	-118.31498	PV1, ROOF MOUNTED SOLAR SYSTEM. (12) MODULES AND (1) INVERTER-3.8KW. TOTAL SIZE IS 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52794	15041-10000-17983	2524 S PACIFIC AVE	90291	11	105A145   184	4227010008	RD1.5-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	33.98241	-118.46777	PLAN CHECK FOR ENERGY ONLY FOR DELI. 2008 TI-24, TOTAL SQ FT. 2500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52795	16041-20000-05773	1377 N SERRANO AVE FLOOR 1-3	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.0965	-118.30717	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement/chance of use from motion picture film editing to office to floors 1 - 3 (building has a total of 6 floors). Total lighting area = 62,311 sq. ft.PLAN CHECK ONLY FOR ALL 3 FLOORS.PERMIT FOR 1ST FLOOR UNDER  # 16041-20000-08761 ( 1ST FLOOR: 20,823 SQFT)PERMIT FOR 2ND FLOOR UNDER #16041-20000-08764 ( 2NDFLOOR: 20,986 SQFT)PERMIT FOR 3RD FLOOR UNDER #16041-20000-08766 ( 3RD FLOOR: 20,502 SQFT)Note: Building application has been generated under 16016-10000-03638 (1st Floor), 16016-10000-03605 (2nd Floor), and 16016-10000-03607 (3rd Floor).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52796	19041-20000-35419	515 S FIGUEROA ST 11TH FL-RSTM & COR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.05199	-118.25764	T24 PLAN CHECK FOR HALLWAY AND RESTROOMS ON 11TH FLOOR OF EXISTING COMMERCIAL HIGH RISE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2428 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52797	17041-20000-37634	15900 W VALLEYVIEW CT 1st & 2nd-Fl Bathrm	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for energy only. TI to 1st and 2nd floor bathrooms in commercial building. New lighting - 1,475sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52798	11041-20000-11180	20401 W PRAIRIE ST	91311	12	198B109    91	2748022085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Finaled	08/12/2011 12:00:00 AM	ADDRESS	34.23922	-118.57764	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR WAREHOUSE OFFICE SPACE INTERIOR REMODEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52799	14041-20000-03229	11740 W WILSHIRE BLVD	90025	11	129B145   644	4263009030	R4-1, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.04876	-118.46141	Repair and replacement of fire damaged units on 10th and 11th floors. PLAN CHECK IN ACCORDANCE TO 2008 NEC PER BUILDING PLAN CHECK SUBMITTAL. TOTAL REMODEL UNITS OF 20 UNITS. RECONNECTION OF 20 ADDITIONAL FEEDERS. SCOPE OF WORK TO INCLUDE REPLACE 20 EXISTING UNITS WITH NEW AC UNITS ON 12TH AND 13TH FLOORS. EXISTING DISTRIBUTION EQUIPMENT TO BE FIELD INSPECTED FOR INTEGRITY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52800	19041-20000-31482	4950 W SUNSET BLVD 3rd Floor	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM	ADDRESS	34.09786	-118.29745	General radiation equipment replacement for (E) medical office facility.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52801	10041-20000-21966	21300 W ERWIN ST	91367	3	177B105    36	2149005042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Public Safety Only			11/03/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.18266	-118.59548	PLAN CHECK FOR FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52802	13041-10000-36057	8500 W BEVERLY BLVD 767	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	pc for energy only. MALL. TI TO BURBERRY <400A TOTAL CONNECTED LOAD. with emergency lights. TENANT IMPROVEMENT OF AN (E) 4,365 S.F. RETAIL SPACE IN A COVERED MALL. SCOPE OF WORK: DEMOLITION OF (E) NON-STRUCTURAL WALLS, (E) STOREFRONT, (E) INTERIOR FINISHES AND RELOCATE (E) UNISEX RESTROOM. WORK TO INCLUDE (N) NON-STRUCTURAL WALL,S (N) STOREFRONT, (N) INTERIOR FINISHES, (N) CEILING, (N) LIGHT FIXTURES AND RELOCATE (E) UNISEX RESTROOM WITH FIXTURES. NO CHANGE IN USE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52803	17041-10000-03971	2222 N MARAVILLA DR	90068	4	150B181   103	5549013025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Expired	09/13/2022 12:00:00 AM	ADDRESS	34.11034	-118.34337	ROOF MOUNTEDPC FOR PV SYSTEM TOTAL OF 9.8KW AC USING BATTERY BACK UP INVERTER RATED 6KW AND 3.8 INVERTER ON THE SIDE. TOTAL OF 28 PV MODULES. PV LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52804	19041-20001-34461	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	10/23/2020 12:00:00 AM	ADDRESS	34.13829	-118.34154	PV2.  Install 140.4 kW AC / 173.565 kW DC roof mounted grid tied PV system.  (399) modules with (14) 9 kW and (1) 14.4 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52805	18041-30000-01558	864 S ROBERTSON BLVD 1ST&2nd-Rest Room	90035	5	132B169   100	4333015025	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.06106	-118.38339	Plan check for Title 24 only in existing restroom 1st and 2nd floor restroom. Toal area: 320 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52806	19041-10000-32281	5746 W VENICE BLVD	90019	10	126B177   592	5064021003	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	07/25/2020 12:00:00 AM	ADDRESS	34.04265	-118.36393	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52807	16041-30000-24356	10212 N GAVIOTA AVE	91343	12	204B141   502	2669009028	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.25601	-118.48254	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52808	14041-20000-30993	17043 W PARTHENIA ST	91325	12	195B133   432	2690010004	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.22865	-118.50404	Roof mounted PV system with microinverter model M215-60. Total system size 4.75KW.Note: The solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52809	19041-20000-32202	11000 N CANBY AVE	91326	12	210B125   575	2715003033	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.26983	-118.53474	Plan check for PV roof mounted PV system, PV system size: 11.5KW with 35 PV Modules and 35 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52810	12041-10000-19142	21230 W PROVIDENCIA ST	91364	3	168B105   296	2167011037	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.15874	-118.59444	New7.848kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52811	15041-20000-34161	4330 N PETIT AVE	91436	5	165B137   180	2291004005	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Expired	11/09/2017 12:00:00 AM	ADDRESS	34.14991	-118.49555	PV1, roof mtd. solar 6.36 kW system. (24) modules #KU2656ZPA, (1) INVERTER PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52812	17041-10000-38737	7001 WORLD WAY WEST Gate 130	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	33.94447	-118.41469	Install 2 @ 220KVA Generators and 2 @ 150HP motors in a non-classified area for sanatery system at Gate 130 of LAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52813	13041-20000-03290	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM			PC Approved	02/08/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Change to lighting to an existing office space.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52814	11041-10000-06961	732 E 10TH ST 103	90021	9	124-5A211 354		M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	04/20/2011 12:00:00 AM	ADDRESS	34.03504	-118.25099	TI IN AN CLOTHING STORE IN UNIT #103 ON THE 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52815	17041-10000-08674	19161 S HARBORGATE WAY 1st Floor	90501	15	060B193   442	7351021044	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	33.85627	-118.30374	Plan check for Title 24 only in existing space T.I. on the 1st floor Total area: 3248 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52816	15041-10001-24067	1500 W PACIFIC COAST HWY Bldg H	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION of 96 devices and 2 power supply for future ADA requirement.(((NEW FA SYSTEM FOR A New 3-story, 36 unit apartment with garage, 100 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52817	10041-20004-24663	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Info Complete	01/15/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	[[[ 1/7/16 CHANGES TO APPROVED SET. DELTA 67 CHANGES ONLY. CHANGES TO SHORTCIRCUIT RATINGS OF PANELBOARDS. SHORTCIRCUIT STUDY HAS BEEN PROVIDED.]]]]]PLAN CHECK FOR LOST SET OF PLANS. RECHECK THIS ENTIRE SET AS NEW. PER BUILDING PC IN ACCORDANCE TO 2008 ENERGY CODE. PERMIT WILL BE ISSUED FOR DIFFERENCE IN INSPECTION ITEMS FROM ORIGINAL APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52818	13041-10000-34458	1751 1/2 W 36TH PL	90018	8	120B193  1339	5041014037	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.02209	-118.31047	PV1, Install a 2.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52819	15041-10001-01167	6944 S KNOWLTON PL	90045	11	102B173   375	4103013008	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			12/05/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	33.97371	-118.37115	CHANGES OF APPROVED SET OF PLANS. CHANGES UNDER DELTA 3 AS REFLECTED ON SINGLE LINE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52820	15041-20001-36731	3007 N LAKE GLEN DR	90210	4	159B161   426	4386003017	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.1282	-118.40932	Expedite fees.Plan check for a PV1 ground-mounted PV system. System size is 15.4 kWac and consists of (2) inverters, (45) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52821	19041-20000-21294	13630 W WILLARD ST	91402	6	189B157   147	2213019041	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.2175	-118.42943	Plan check for power and energy for new lighting  and equipment in General Radiology room. Total area: 491 sq ft. B#19016-10000-16454	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52822	19041-10000-19446	601 S FIGUEROA ST 12TH FL	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Energy plan check for an office T.I located in the 12th floor of a high rise building. Scope inlcudes new lighting and equipment with a total lighting area of 17,881-SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52823	12041-10000-00430	333 S LOS ANGELES ST	90013	9	129A213   149	5148001006	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.04788	-118.24566	PLAN CHECK POWER. ENERGY, NEW 13.2 KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR EXISTING TYPE R1OCCUPANCY BUILDING. EXISTING 800A SERVICE, NEW DISTRIBUTION BOARDS, PANELS, EQUIPMENT, AND ADDITIONAL CKTS. VARIANCE TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52824	15041-10000-14818	9769 W PICO BLVD	90035	5	132A165   307	4330013024	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.05431	-118.40168	Energy plan check for a commercial building ( Roxbury Market place) T.I ; Scope includes service upgrade to 400-Amp ,new lights, ewuipment and  receptacle outlets.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52825	19041-30000-16866	11601 W WILSHIRE BLVD Suite 2400	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 only. Project site is an existing tenant suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 3,484 sq. ft.Note: Building permit has been issued under 19016-40000-10982	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52826	14041-20000-25174	4100 N BAKMAN AVE	91602	2	162B173   261	2366033037	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2014 12:00:00 AM	09/12/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.14234	-118.37774	PV1STANDARD PLAN CENTRAL TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52827	12041-20000-16126	6350 W 3RD ST	90036	4	138B177   796	5509018009	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	08/15/2012 12:00:00 AM	ADDRESS	34.07119	-118.36054	Changes from previously approved plans.  Change the indoor lighting.  Plan check for lighting only.Note: Applicant unable to provide the previous approved plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52828	16041-10000-21030	5912 W ABERNATHY DR	90045	11	099B169    59	4105006023	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Expired	07/19/2018 12:00:00 AM	ADDRESS	33.97119	-118.38561	PV1 rooftop solar installation, 4.2 kW AC   (20) KU2656ZPA     (1) PVI-4.2-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52829	14041-10000-16287	818 W 7TH ST 850	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.04895	-118.25943	permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A. high rise. BLDG#14016-10-11768:TENANT IMPROVEMENT  APPROX 5183 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52830	12041-10000-31122	3849 E FILION ST	90065	14	156B213   227	5459017020	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.12412	-118.23465	PV1 3 STORY HOUSE 22 MODULES [MODULES: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52831	18041-10002-18230	8525 N VARIEL AVE	91304	3	192B105   176	2779011036	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2018 12:00:00 AM			PC Approved	07/13/2018 12:00:00 AM	ADDRESS	34.22506	-118.59302	[[[7/13/18 CHANGES TO APPROVED. PLANCHECK ONLY FOR DELTA 1 CHANGES. CHANGES INCLUDE RELOCATING THE INTERCONNECTION OF SOLAR INTO EXSITING 400AMP 120/240 SPLIT BUS SINGLE PHASE SERVICE]]]]PV1, roof mounted solar system using central inverters. (88) modules and (3) 7KW inverters. Total system size is 21KWAC and 23.6 KWDC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52832	14041-20001-03594	8407 N CREBS AVE	91324	12	192B121   500	2785013026	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	02/15/2014 12:00:00 AM	ADDRESS	34.22305	-118.54386	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52833	14041-20001-24992	4365 S PURDUE AVE	90066	11	111B161   320	4217006021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.00124	-118.41377	EXPEDITE PER CUSTOMER REQUEST.PLAN CHECK FOR RESIDENTIAL SERVICE UPGRADE TO TWO HUNDRED AMPS WITH PV SYSTEM SIZED 5KW INTERCONNECTED WITH MAIN SERVICE.PLAN CHECK FOR ENERGY AND POWER.PROJECT FUNDED BY CITY OF LOS ANGELES.SUBMITTAL REQUESTED BY CUSTOMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52834	18041-10000-13746	10201 W PICO BLVD BLDG 54	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	02/18/2022 12:00:00 AM	ADDRESS	34.04994	-118.41129	INSTALL NEW FIRE ALARM SYSTEM FOR 2-STORY OFFICE BUILDING (BLDG #54).  (1) FACP,  (31) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52835	17041-10000-32199	2021 N WESTERN AVE	90027	4	151-5A193 483	5587022022	RE11-1	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.10746	-118.30946	TITLE 24 PLAN CHECK FOR REPLACEMENT OF EXISTING (29)HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA  105700 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52836	17041-20001-38937	7831 N GENESTA AVE	91406	6	189B133   677	2204019005	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.21306	-118.50417	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 21.12 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52837	15041-20000-25392	5525 N SEPULVEDA BLVD	91411	4	174B145   590	2250001035	C2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.17114	-118.46644	Plan check Title 24 only for existing restaurant Denny's. Total  indoor area: 3,548 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52838	15041-10000-11478	1744 S SANTEE ST	90015	14	123A207   185	5127022013	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.03038	-118.26196	IN AWAREHOUSE/OFFICE, REPLACING LUMINAIRES WITH LEDSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52839	14041-20001-34872	4420 N ALFARENA PL	91356	3	165B121   109	2177021004	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			PC Approved	12/29/2014 12:00:00 AM	ADDRESS	34.15156	-118.5446	EXPEDITED PER CUSTOMER REQUEST.PV1. ROOF MOUNTED PV SYSTEM SIZED 11.4 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(49) SOLAR WROLD 275W MODULES(49) SOLAR EDGE P300 POWER OPTIMIZERS(1) SOLAR EDGE SE11400A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52840	10041-20000-21989	334 N LA BREA AVE	90036	5	138B181   227	5525032005	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	34.07726	-118.34384	Plan check T24 Energy (general/emergency) lighting for bookstore TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52841	16041-10000-37027	1629 W 6TH ST	90017	1	132A205    47	5153005001	C2-4	Central	Westlake	Westlake North		2091.02	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.05739	-118.26962	PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 4375 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52842	14041-10002-15005	20750 W SHERMAN WAY	91306	3	183B109    80	2137020037	(T)RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Apartment			04/08/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	34.20086	-118.5852	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGE ALL FEEDERS FROM FROM AL TO CU.  PLAN CHECK FOR POWER ONLY.  CHANGES NOTED DELTA 1.NEW 3-STORY,  95 UNIT ELDER CARE FACILITY: 94 SENIOR UNITS (32 Independent units & 62 Assisted Living units),  ONE MANAGERS UNIT and ONGRADE PARKING LOT per ZA2012-0644-ELD-SPR.  New 2000A service, panels, circuits, and lighting.  Plan check for power and energy.Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52843	16041-10000-44246	11701 W WILSHIRE BLVD #15-#16	90049	11	129B145   573	4265010084	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.04949	-118.4611	Plan check Title 24 only in existing retail space #15 T.I. Total area: 1,434 sq ff	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52844	12041-10000-05184	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	PIN	33.93847109	-118.41935625	Energy only. Install outdoor lighting for a new parking lot for Police department in LAX area.  Power will be taken from an abandoned building on property. Project scope consists of  (7) new luminaires, (1) new 20A enclosed breaker, (1) new 30A lighting contactor, (1) new photo cell. Above/below grade raceways and conductors will also be installed. Lighting will be on 480V.  Square footage of 157,000 square feet with 2,250 foot perimeter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52845	16041-20000-01277	15511 W LA MAIDA ST	91403	5	168B141   277	2261036032	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	PIN	34.15875761	-118.47247489	Install roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derating main to 175A.System size: 8.8kW (3.8kW + 5kW). (31) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52846	19041-10000-07774	920 W BLOOM WALK #715	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.01996	-118.28938	TENANT IMPROVEMENT IN EXISTING LASER LAB IN ROOM # 715 OF USC UNIVERSITY PARK CAMPUS. (USC - SEAVER SCIENCE CENTER ROOM 715). INSTALLING NEW LIHTS. T-24 ENERGY ONLY. BULDING PERMIT: 19016-10000-06137	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52847	13041-10000-07127	13955 N BALBOA BLVD	91342	7	228B137   226	2603025028	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	05/08/2013 12:00:00 AM	ADDRESS	34.323	-118.49033	FA WAREHOUSE INDUSTRIAL NONHAZARDOUS PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52848	18041-20001-47169	12400 N WOODLEY AVE	91344	12	219B137    79	2605005010	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.29607	-118.49338	PLAN CHECK ONLY CHANGES TO APPROVED SET. ADDITION OF A TESLA POWER WALL AND MODULE MODEL SWAP FROM SC325 TO SC330'S. SOME CHANGES TO CONDUCTOR AND BREAKER VALUES. CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52849	19041-20000-16123	20750 W BEECH CIR #313-pv1	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.29391	-118.58547	pv1install roof mounted pv system sized 3.02KW AC interconnected with msp.(9) acm at 335 W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52850	14041-20000-00792	5510 S LINCOLN BLVD 2nd FLOOR	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	33.97299	-118.43051	T24 FOR EXISTING NONHIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE SECOND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52851	13041-20002-33708	16304 S VERMONT AVE	90247	15	069B197   333	6120018084	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Apartment			11/21/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	33.88328	-118.29117	new 79 units apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52852	19041-20000-02904	3576 N LOWRY ROAD	90027	4	154-5A203 292	5592008022	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.11638	-118.27726	pc for 2 eneregy storage systems, each is 13.5Kwh-Tesla power wall model. 1 load center 125A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52853	14041-20000-24837	7010 S HOOVER ST Unit #5	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #5. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52854	13041-10000-03699	7701 N PENFIELD AVE	91306	3	189B113  1228	2106008018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.21072	-118.56915	"PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE STORY HOME. [INVERTER: SUNPOWER #SPR-7000M |||| MODULES: SUNPOWER # SPR-327NE-WHT-E] 24 MODULES IN FOUR STRINGS. SYSTEM SIZE IS 7.84 KW.""COMPLY WITH DEPARTMENT ORDER effective date09/10/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52855	11041-20000-09524	2121 S AVENUE OF THE STARS SUITE2000	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	09/28/2011 12:00:00 AM	ADDRESS	34.05554	-118.41342	ti ENERGY PLAN CHECK SUITE 2000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52856	13041-20000-17269	11281 W HUSTON ST	91601	2	168B173   101	2353016016	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			06/28/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.16001	-118.37716	New 8-unit apartment building.  Not a methane site.  600 amp service.  Full Plan Check. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52857	18041-10001-14335	2626 W COLORADO BLVD	90041	14	163-5A219 162	5682002024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			PC Approved	05/07/2018 12:00:00 AM	ADDRESS	34.14192	-118.22342	PLAN CHECK ONLY. CHANGES TO AN APPROVED SET UNDER DELTA 1 CLOUD CHANGES. CHANGES FROM 600A NON FUSED TO 600A FUSED DISCONNECT.  ______________________________________________________________________(((PC FOR NEW COMMERCIAL ROOF MOUNTED (ON A TARGET STORE) 3PHASE PV SYSTEM. SCOPE INCLUDES 840 MODULES AND 6 INVERTERS. TOTAL SYSTEM SIZE 323KW.AC AND A 365.4 KW.DC B#18016-10000-12055	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52858	16041-20000-09556	4318 S KANSAS AVE	90037	9	114B197  1199	5020025014	R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Apartment			03/18/2016 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	03/04/2022 12:00:00 AM	ADDRESS	34.00489	-118.29359	Plan check for power and energy. Project site is a new 3-story, 22-unit apartment building. Total lighting area = 21,165 sq. ft.Note: Building application has been generated under 16010-20000-00549	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52859	14041-20000-11139	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.04443	-118.29612	PC FOR T24 ENERGY ONLY. NEW LIGHTING FOR EXISTING LIBRARY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52860	19041-10000-14432	303 S GAFFEY ST	90731	15	018B197  1550	7451020033	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	33.74122	-118.29251	Plan check for (4) NEW INFORMATION SIGNS LOCATED IN THE DRIVE THOUGH AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52861	11041-10000-00307	1521 W PICO BLVD # 108	90015	1	127-5A203 102	5137032023	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.04432	-118.27583	TENANT IMPROVEMENT IN RETAIL SPACE-NEW PANEL/CKTS/LIGHTINGPLAN CHK IS FOR TITLE 24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52862	11041-10001-15420	153 N GLENDALE BLVD 1-4	90026	13	135A209   300	5159015032	C2-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Apartment			09/30/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	34.06346	-118.26018	REVISIONS TO PERMITTED SET OF PLANS-EMERGENCY LUMINAIRES IN THE CORRIDORS ON EACH FLOORNEW 3 STORY 45 UNITS APARTMENT BUILDING OVER 1 LEVELS OF GARAGE AND ONE LEVEL OF COMMERCIAL IN A MIXED USED BUILDING. <<<VARIANCE FOR FIRE LIFE SAFETY SYSTEM  has been submitted	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52863	19041-10000-29691	6150 N LAUREL CANYON BLVD	91606	2	177B165  1100	2334011029	(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	06/15/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	FULL PLAN CHECK FOR FIRST TIME TENANT. SCOPE OF WORK INCLUDES NEW LIGHTING, PANELS AND CIRCUITS. T-24 USING TAILORED METHOD, TOTAL SQ. FT. 1113.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52864	15041-10000-25437	2155 N STRADELLA ROAD	90077	5	150B145    31	4377028001	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Expired	09/15/2017 12:00:00 AM	ADDRESS	34.11089	-118.46248	Permit fee is 0.00 due to Senate Bill 1222.PV112KW ROOF MOUNTED SYSTEM WTIH (55) kYOCERA KU26556ZPA MODULES AND (2) ABB PVI-6000-OUTD INVERTERS INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52865	18041-10000-24701	3045 S CRENSHAW BLVD	90016	10	120B185   700	5050031040	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.02629	-118.33529	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52866	12041-20000-15467	601 S FIGUEROA ST	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I. to a high rise building on the 3rd floor.  Install general/emergency lighting in corridor area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52867	15041-20000-10066	8452 N RANCHITO AVE	91402	6	192B153   275	2637032009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.22499	-118.43666	Plan check for PV1 4.2kW(ABB PVI04.2-OUTD-US-A) with 17 modules(HYUNDAI HIS-M250RG). Derated the main circuit breaker to 175A. Applicant provided the load calculation.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52868	16041-10000-05604	10760 N DES MOINES AVE	91326	12	207B117   189	2728001012	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Expired	04/02/2018 12:00:00 AM	ADDRESS	34.26519	-118.55434	PV1, INSTALL 12.43 KW DCROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(38) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTER: SMA SB6000TL& 5000TL US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52869	13041-20000-28449	22601 W LASSEN ST	91311	12	204B101   525	2724005902	A1-1XL	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11, 1132.13	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.25009	-118.61925	T24 FOR CHANGE OF USE FROM CARETAKERS RESIDENCE TO FLOWER SHOP. TOTAL CONNECTED LOAD DOES NOT EXCEED 400A PER APPLICANT. EXISTING SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52870	15041-10000-20819	1925 S CENTURY PARK EAST STE.460	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI-24 FOR NEW OFFICE LAYOUT,  INSTALL LIGHT FIXTURES, CONTROLS, AND RECEPTACLES, NO NEW PANNEL ADDED. TOTAL AREA: 2328 SQ. FT. P/C FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52871	16041-20001-14138	3515 W HYDE PARK BLVD	90043	8	105B185  1231	4006007028	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			11/06/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	ADDRESS	33.98072	-118.33417	Change of lighting controls to corridors/common areas from low voltage to line voltage controls.  ((Plan check for power and energy. NEW 5-STORY 51 UNIT APARTMENT BUILDING. 1200A service.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52872	16041-20000-39552	4705 N LAUREL CANYON BLVD Suite 500	91607	2	168B165   697	2356037030	[Q]C2-1VL-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.15593	-118.39668	Plan check for energy only. TI to office suite 500. New lighting (including emergency). 4,881sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52873	14041-20000-05602	10647 W ASHTON AVE	90024	5	132B153   219	4326001023	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			02/28/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.06015	-118.43457	New 4-story apartment with subterranian parking.  New 1200A service. Plan check for power and energy.Note: A variance to separate fire alarm plans is submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52874	19041-10000-12801	412 S LOS ANGELES ST	90013	14	129A213   261	5148007003	C2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	34.04687	-118.24645	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52875	19041-10001-07703	2155 N STRADELLA ROAD	90077	5	150B145    31	4377028001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.11089	-118.46248	EXPEDITED FEESPV1 ROOF MOUNTED SYSTEM USING CENTRAL INVERTER AND POWER OPTIMZERS. TOTAL NUMBER OF MODULES 44, 44 OPTIMZERS , (2) 7.6 KW INVERTERS. TOTAL SYSTEM SIZE 15.8 KW DC, 14.05 KW AC CEC, 15.2 KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52876	15041-10000-07114	803 W 69TH ST	90044	8	102B197   586	6013008029	C2-1VL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	05/30/2015 12:00:00 AM	ADDRESS	33.97737	-118.28726	PV1 ROOF MOUNTED STANDARD PLAN TOTAL SYSTEM SIZE 4.2KWAC. 21 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52877	17041-10001-34261	1120 W WASHINGTON BLVD	90015	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	PIN	34.03794253	-118.28208997	PC for changes to approved set of FA system. Installing 261 devices and two remote power supply panels. All changes clouded and boxed on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52878	12041-20000-29762	1015 W 34TH ST # B2	90089	9	120B197   699	5039002032	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	12/11/2012 12:00:00 AM	PIN	34.02460032	-118.28769856	T-24 lighting plan check for storage room and restroom.  Indicated as B2 on the plan.  The location is in the basement of the Webb Tower building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52879	13041-20000-31846	2704 S BEVERLY DR	90034	5	126B165  1018	4309025010	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.03809	-118.39585	pv1 single family dwelling. total system size 6 kw ac using 25 modules. 2 strings. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52880	13041-20001-22296	2603 W SAN FERNANDO ROAD	90065	1	150B213   379	5457007001	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.10877	-118.2411	Plan check for energy and outdoor lighting. Indoor and outdoor lighting. Patio Futures  LLC.(((change in lighting. plan check for changes.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52881	16041-10000-24559	3707 S HILL ST	90007	9	117A203    42	5122028001	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.01611	-118.27736	PV2 roof mounted solar system installation to a commercial site 4 story building used for storage. Installing 8 central inverters rated at 28 Kw each (PVI 28TL) for a total system rating of 224 Kw, and 768 Solar moduels (Canadian Solar CS6X-320P).**NOTE: FEES ARE $0 DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52882	14041-20000-31977	9945 W BEVERLY GROVE DR	90210	5	147B157   501	4356021036	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM			Reviewed by Supervisor	12/05/2014 12:00:00 AM	ADDRESS	34.09549	-118.42591	PLANCHECK FOR POWER AND ENERGY FOR A NEW SINGLE FAMILY DWELLING. 2 STORIES WITH BASEMENT  WITH ATTACHED GARAGE. 600 AMP SERVICE. THIS IS PLAN CHECK ONLY. PERMIT HAS BEEN ISSUED WITH BUILDING/COMBO PERMIT FROM BUILDING DEPARTMENT. THIS IS PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52883	12041-10000-12536	4424 N LA BARCA DR	91356	3	165B117    88	2177006013	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	ADDRESS	34.15095	-118.55186	New roofmounted photovoltaic system for a single family dwelling 8.7KW system using Enphase M215 Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52884	15041-20000-37014	5602 N AMORITA PL	91367	3	174B109   344	2151023009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.17343	-118.5818	Install a roof mounted solar array on a SFD, interconnect with subpanel for existing solar system on roof. New inverter is 5kW and is ungrounded. Existing system is 7.6kW. With additional 5kW, total system size is now 12.6kW.(23) new 265W pv modules connected to new 5kW inverter. MSP is 200A, derating main to 150A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52885	19041-10000-19706	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey, Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	33.98095	-118.40764	PC FOR A NEW FIRE ALARM SYSTEM IN AN EXISTING COMMERCIAL BULDING WITH 290 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52886	13041-10000-10675	939 S HILL ST	90015	14	127-5A209 229	5139004008	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.04215	-118.25823	PLAN CHECK FOR 281 UNIT AND 3 LIVE/WORK UNIT 5-STORY APARTMENT BUILDING WITH TWO 5000A  SERVICES. PLAN CHECK FOR POWER AND ENERGY. SITE LOCATED IN METHANE ZONE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM FROM PLANS ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52887	17041-20001-20865	3814 N GLENEAGLES DR	91356	3	162B117   266	2180019019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM			PC Approved	06/26/2017 12:00:00 AM	ADDRESS	34.13912	-118.56429	Expedited plan check fee.  PV1.  Install 13.44 kW roof mounted grid tied PV system.  (42) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52888	15041-20001-34169	23314 W FRIAR ST	91367	3	177B093    36	2035020033	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.18526	-118.63467	EXPEDITE FEESPV1 SFD TOTAL SYSTEM SIZE 10.2KW AC USING TOTAL OF 2 CENTRAL INVERTERS AND 49 MODULES. SOLAR LOAD CENTER INCLUDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52889	14041-20001-35859	1659 E 47TH ST	90011	9	112-5A213 345	5106014020	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	34.00111	-118.24428	Expedited per customer request.PV1. Install roof mounted PV system sized 10 KW. Interconnected with main service pannel. (32) Sunpower 327W Modules(2) PVI-5000- TL Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52890	19041-10000-16316	5555 W MELROSE AVE Stg 1 & 2-Head	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	01/13/2021 12:00:00 AM	ADDRESS	34.08363	-118.32191	PC FOR POWER IN PRODUCTION BLDGS (Stages) 1 & 2 + OFF BLDG 208 (Head)  NEW DITRIBUITION FED FROM MIDIUM VOLTAGE 800A 3PH 3W 480INCLUDING NEW EQUIPMENT AND CIRCUITS. B#19020-10000-01132	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52891	15041-20000-29945	5957 N LAUREL CANYON BLVD	91607	2	177B165   793	2340004029	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.17887	-118.39677	Plan check for power and energy for new one story retail bldg(3 retail spaces)Note: 2 separate building on the same plan and take in as 1 PCAMNote: Building permit has been issued under 14010-20000-01600	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52892	10041-10000-22111	700 W IMPERIAL HWY	90044	15	087A199   243	6088002001	C2-1VL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.00, 2413.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	ADDRESS	33.93073	-118.28718	TI IN AN EXISTING RETAIL. PLAN CHECK FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52893	13041-10000-09567	12026 N NUGENT DR	91344	12	216B129   129	2601027051	RE15-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.29006	-118.51541	INSTALL ROOF- MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 8.82KW. INVERTERS: SUNNY BOY 7000-US. TSM-245, 36 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52894	19041-20000-49373	6204 S BERTHA ST	90042	14	153A231   364	5492028020	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1837.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	02/08/2020 12:00:00 AM	ADDRESS	34.11197	-118.18642	PV1.  Install 9.12132 kW rated solar roof system.  (156) shingle modules and 7.6 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52895	13041-20001-29994	821 N STRADELLA ROAD	90077	5	141B149   114	4369023011	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	34.08375	-118.45353	((CHANGES MADE TO APPROVED SET OF PLANS. CHANGED LAYOUT OF PANELS. NOTHING ELSE HAS CHANGED FROM THE APPROVED SET. THIS IS A PLAN CHECK ONLY APPLICATION))pv1 single family dwelling. total system size 6.4 kw ac using 30 modules. using enphase microinverter. standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52896	14041-10001-04112	2916 W FRANCIS AVE	90005	1	132B197   658	5077024002	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.0567	-118.28969	PV1.  Install 5.886 kW DC roof-mounted PV system on rear garage (load center in interior storage room), interconnect with main service panel at main house.  18 modules: SunPower SPR-327NE-WHT-D.  Transformed inverter: SRP-5000m	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52897	17041-10003-04636	20215 W RINALDI ST BLDG S4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	34.27499	-118.57438	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  28. CHANGES INCLUDE REMOVING ELECTRICAL CIRCUITS ON THE PANEL SCHEDULES. NOTE: PERMIT HAS BEEN PULLED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52898	18041-10000-38015	1155 N LEMOYNE ST	90026	13	139-5A209 139	5404016900	R4-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1975.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.07717	-118.25989	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52899	17041-10002-19840	968 N SOMERA ROAD	90077	5	144B149   325	4369033014	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.0879	-118.45678	Supplemental PC for change of elevation height of Tesla Powerwall to be 3ft above grade level.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52900	19041-10000-42067	1742 W 84TH PL	90047	8	097-5A193 143	6034025020	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	08/04/2020 12:00:00 AM		Issued	08/04/2020 12:00:00 AM	ADDRESS	33.96169	-118.30836	$0 Fee per AB1414. PV2, NEW ROOFTOP MOUNTED PV SYSTEM, SYSTEM SIZE IS 25.2KWac/36.3KWdc. SCOPE OF WORK IS 99 MODULES (HIS-S370RI) ALL WITH OPTIMZERS (SE P400), LEADING TO THREE CEMTRAL INVERTERS (TWO SE7600H-US AND ONE SE10000H-US), LEADING TO A PV SUBPANEL, INTERCONNECTING TO AN EXISTING SERVICE (PLAN CHECKER TO VERIFY SERVICE SIZE AND FAULT CURRENT).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52901	17041-20000-37540	8612 N RIVENDELL CT	91306	3	192B113    94	2782011036		North Valley				1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.22614	-118.57017	Plan check for solar pv system, roof-mounted array on SFD.4.76kW ungrounded system. (17) EnPhase IQ6 microinverters.(17) 360W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52902	19041-10000-06936	4131 S GLENCOE AVE	90292	11	108B153  1196	4230005034	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	33.98906	-118.44215	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52903	17041-10000-13352	1026 N RAMPART BLVD	90026	13	141A205   330	5402014012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.07929	-118.27017	PC FOR NEW PV SYSTEM ON ROOFTOP SFD, 3.8KW AC USING CENTRAL INVERTER WITH 10 MODULES AND POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52904	13041-10000-11066	10911 W CHALON ROAD	90077	5	141B149    68	4369028001	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.08453	-118.45569	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 4.41KW. TWO STRINGS AND A SINGLE INVERTER.  [MODULES: TRINAL SOLAR # TSM--245PC05 ||| INVERTER: POWER-ONE # AURORA PVI-3.6-OUTD-S-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52905	17041-10000-25883	953 N SYCAMORE AVE	90038	4	144B181   641	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	New Fire Alarm system on an 8-story Media Production Office Building with 2-levels of subterranian parking. Total 409 devices and 4 FA panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52906	18041-10000-12936	13420 W CHALON ROAD	90049	11	138B133   357	4492003002	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Expired	06/02/2024 12:00:00 AM	ADDRESS	34.07333	-118.50037	PC FOR ADDITION OF 2 STRINGS TOTAL OF 14 MODULES (TRINA  TSM-300D05A)TO AN EXISITING, ROOF MOUNTED, PV SYSTEM FINALED UNDER 15041-90000-22699TOTAL NEW SIZE 12.945KW DC. AC SIZE TO REMAIN AT 9.6KWAC (USING EXISTING CENTRAL INVERTERS).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52907	15041-10000-39639	16777 W BOLLINGER DR	90272	11	129B121  1018	4415008021	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.04544	-118.54521	PV1, ROOF MOUNTED SOLAR SYSTEM WITH AC MODULES AND A SUN POWER MONITOR TYING INTO A 15AMP BREAKER. (16) SUNPOWER, SPR-X20-250-BLK-B-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52908	15041-20000-43767	4094 S GLENCOE AVE	90292	11	108B153  1063	4230006003	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	33.99	-118.44273	PC for Energy Only. Total area: 15,462sq.ft. ((CHANGE OF USE AND NEW INTERIOR SECOND LEVEL ADDITION FROM WAREHOUSE TO OFFICE))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52909	12041-10000-18686	8824 N COMANCHE AVE	91306	3	195B113   209	2781031028	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2012 12:00:00 AM			Corrections Issued	08/18/2012 12:00:00 AM	ADDRESS	34.23082	-118.57203	Plan check for new roof mounted 9.60KW photovoltaic system (Kaco transformerless inverters) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52910	17041-20000-37257	18838 W MAPLEWOOD LANE	91326	12	207B121   835	2728031007	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.26014	-118.54413	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.73KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52911	13041-10001-26186	10948 N OSO AVE	91311	12	210B113   138	2707031008	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.26913	-118.57623	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLARY ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 14.5kW. 58 TSM 250 MODULES. UNG ROUNDED SYSTEM. 2 POWER ONE PVI 6000 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52912	10041-10000-03932	13065 W BLUFF CREEK DR	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/25/2010 12:00:00 AM	ADDRESS	33.97037	-118.42371	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52913	15041-10002-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR CHANGES TO APPROVED SET OF PLANS. CHECKING FOR DELTA 6,7,8.  MAINLY CONDUIT REVISIONS. OTHER REVISIONS INCLUDE LIGHTING AND CONTROLS. UPDATED TITLE 24 AND UPDATED PANEL SCHEDULES TO REFLECT FLOOR PLANS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52914	14041-10000-09287	324 S JUNE ST	90020	4	135B185   154	5505003003	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Expired	07/18/2016 12:00:00 AM	ADDRESS	34.06802	-118.33405	PV1, Install 2 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3000A-US-ZB-U. (8) Modules: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52915	18041-10000-46988	6801 W HOLLYWOOD BLVD #B-153	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.10229	-118.33907	"Plan check for T24 only, TI on (E) commercial space ""Ben&Jerry's"" space B-153. New loads are connected to existing panelboard. Total area: 1,083sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52916	10041-10000-04575	3055 W WILSHIRE BLVD # 1120	90010	10	135B197  1241	5077008016	C4-2	Central	Wilshire	Wilshire Center - Koreatown	YES	2111.20, 2122.04	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	34.06198	-118.28784	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52917	18041-10001-17287	10250 W SANTA MONICA BLVD Delta-42	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	DELTA 42 CHANGES TO APPROVED PLANS.  Revise tenant suite number from 1975 to 1985 on Distribution board DB-ELA44 ON PAGE 3.E.04.13 ONLY.This is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52918	16041-20000-02250	7518 N SUNNY BRAE AVE	91306	3	186B109   395	2113002016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.2071	-118.58071	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel. Standard plan in use.(21) Kyocera KU265 Modules(1) ABB PVI-5000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52919	12041-20000-16251	5340 S ALLA ROAD	90066	11	102B157    39	4211008023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	33.9773	-118.42567	Remodel men and women's restroom, installing luminaires, and receptacles.  Plan check for T-24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52920	16041-10001-13627	1330 W PACIFIC COAST HWY	90710	15	033B197    21	7411007021	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	33.78921	-118.30005	EXPEDITE FEESPV2 ROOFTOP SOLAR ENERGY. TOTAL SYSTEM SIZE 32KW AC USING 2 CENTRAL INVERTERS CONNECTED TO A TRANSFORMER FOR BACKFEED TO MATCH BUILDING VOLTAGE CLASS. TOTAL OF 105 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52921	19041-10001-11607	10074 W SULLY DR	91352	2	189B181    75	2403019012	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM			Reviewed by Supervisor	04/08/2019 12:00:00 AM	ADDRESS	34.218	-118.34978	PV1. NEW SOLAR SYSTEM WITH STORAGE SYSTEM BATTERY. TOTAL SYSTEM SIZE IS 11.4KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52922	15041-10002-37316	616 S KENMORE AVE	90005	10	135B197  1102	5502028022	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			07/16/2018 12:00:00 AM			Corrections Issued	07/16/2018 12:00:00 AM	ADDRESS	34.06289	-118.29646	07/16/2018 Changes to an approved set of plan. Changes include the addtion of fire alarm devices, 9 devices and relocate Fire alarm dvice. Changes apply to delta 2 only. {{{{{{INSTALL NEW FA SYSTEM FOR A 6-STORY APARTMENT BUILDING. 117 FA DEVICES, 1 FA PANEL, 1 FA COMMUNICATION APNEL, AND 4 CONTROL PANEL.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52923	10041-10000-06509	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	Ti for grount level 1st and 2nd floor of existing hotel , power lighting and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52924	14041-10000-30459	1590 E 54TH ST	90011	9	108B213   216	5105004900	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Public Safety Only			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	33.99373	-118.24514	Fire alarm system with (10) new devices and a control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52925	18041-20001-42039	4101 S REDWOOD AVE	90066	11	108B153   929	4230006233	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM			PC Approved	11/19/2018 12:00:00 AM	ADDRESS	33.99086	-118.44043	SUPPLIMENTALFOR CHANGES TO AN APPROVED SET FOR A TI TO AN EXISTING COMMERCIAL BUILDING. DELTA 1 CHANGES TO RESTROOM FIXTURES FROM F2(19 W) TO F2A(9.5 W). PC PER INSPECTOR REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52926	17041-20000-29471	5300 N FORBES AVE	91436	5	171B133   171	2259023009	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.16719	-118.49901	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (12) micro-inverters, (24) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52927	13041-10000-23429	656 S MAIN ST	90014	14	127-5A211 120	5148021012	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Info Complete	08/28/2013 12:00:00 AM	ADDRESS	34.044	-118.25101	existing restaurant. T24 ONLY FOR MEZZANINE AND 1ST FLOOR LIGHTING. SCOPE OF WORK IS REMODOLING OF LIGHTING FIXTURES. TOTAL AREA OF 1726 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52928	15041-10000-36138	111 E UNIVERSAL HOLLYWOOD DR 31ST FL	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	PC FOR ENERGY. T.I FOR OFFICE BUILDING. TOTAL AREA 20278 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52929	19041-10000-17996	5750 W HOLLYWOOD BLVD	90028	13	148-5A191 157	5586035044	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			05/14/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	04/19/2022 12:00:00 AM	ADDRESS	34.10154	-118.31491	plan check for a fire alarm system located in a 7-story and 161 unit apartment building. Scope includes (2) fire alarm panel, 9-control panels ,and 417-fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52930	14041-20000-34490	5121 N COLBATH AVE	91423	4	171B153   579	2269007014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.16367	-118.43668	PV1 SFD. TOTAL SYSTEM SIZE 7.115KW AC USING CENTRAL TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52931	19041-10000-38710	3186 S LELAND ST	90731	15	009B193   898	7469013011	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Expired	10/03/2023 12:00:00 AM	ADDRESS	33.71722	-118.30171	PV1. LADWP Community Solar Program: 5.00KWdc / 3.910KWac - 17 solar modules and 17 enphase IQ7-60-2-US micro-inverters. 1 service interconnected as a new service drop 100ACA.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52932	15041-10000-25019	3120 W LACLEDE AVE	90039	13	153B209  1050	5436010004	[Q]RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.11258	-118.24972	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. 7.8KW SYSTEM. 28 MODULES AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52933	19041-10000-17336	926 N SYCAMORE AVE	90038	4	144B181   760	5532010047	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	12/23/2020 12:00:00 AM	ADDRESS	34.08796	-118.34265	PC FOR FA, PROPOSED 8 STORY TYPE I-B MULTI MEDIA PRODUCTION & SERVICES OVER ONE LEVEL TYPE I-B   SUBTERRANEAN  PARKING GARAGE. SYSTEM CONSITS OF 1 FACP AND 160 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52934	12041-10000-25454	888 S OLIVE ST	90014	14	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			11/15/2012 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.04383	-118.25785	NEW 33 STORIES HIGH-RISE MIXED USE BUILDING ( COMMERCIAL AND 283 UNITS ) OVER PRIVATE PARKING GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52935	18041-20000-11800	2121 S AVENUE OF THE STARS P4 LEVEL-GARAGE	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Issued	04/11/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52936	15041-20001-10536	10600 N PINYON AVE	91042	7	207B201   255	2566001076	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM			PC Approved	04/15/2015 12:00:00 AM	ADDRESS	34.26113	-118.28481	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 5KW AC. THIS IS AN ADDITION OF THE 5KW AC SYSTEM. THE TOTAL PV BACKFEED ADTER INSTALL WILL BE 11KW AC. THIS PERMIT TO COVER NEW INVERTER, PANELS AND SOLAR COMBINER. THIS SYSTEM CONTAINS POWER OPTIMIZERS. THIS PERMIT ALSO COVERS RELOCATION OF EXISTING INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52937	10041-10000-13916	3200 S MOTOR AVE Admin Bldg	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00, 2699.01	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	34.03145	-118.41085	New Administration building. Plan check for Title24, Energy, Regular and emergency lights. Permit is for new service, panels & circuits. Complete EPC may be required, subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52938	13041-10001-33116	8609 N GLORIA AVE	91343	12	192B141    37	2673004029	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.22684	-118.48094	Expedited RSES plan check per applicant request.[][]PV1, Install 4 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE3800A-US. (16)modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52939	18041-20000-16689	10320 W CLUSTERBERRY CT	90077	5	156B153   131	4382025***	RE15-1-H-RPD-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2018 12:00:00 AM	05/07/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.12409	-118.44446	Plan check for PV roof mounted system, system size 5.04kW with 14 AC Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52940	07041-10003-18431	905 N YALE ST	90012	1	135A215   138	5414003015	C2-2D-O	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.06537	-118.23984	REVISED SINGLE LINE TO SHOW THE ADDITION OF A TERMINATION SECTION TO THE SWBD .THROUGH THIS SECTION THE OPTIONAL STANDBY GENERATOR WILL BE CONNECTED TO THE  BUS OF THE SWBD AHEAD OF THE MAIN DISCONNECT WITH A KIRK KEY SET-UP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52941	18041-20000-35265	857 N FORMOSA AVE	90046	5	144B181   843	5525002001	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	PIN	34.08693635	-118.34640304	Plan check for a PV1 roof-mounted PV system. System size is 1.475 kWdc/1.15 kWac and consists of (5) modules and (5) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52942	15041-10000-04412	10900 W WILSHIRE BLVD	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.05848	-118.44419	Plan check for Title 24 only. Project site is a high-rise office building. Total lighting area = 8,540 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52943	11041-10001-27189	1901 S AVENUE OF THE STARS	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.05949	-118.41705	DELTA 4 CHANGES. INSTALL A 1500KVA 4160V:48OV TRANSFORMER FOR NEW CHILLERS AND BOILERS AND MOTORS AT PARKING LEVEL. PLAN CHECK POWER FOR CENTRAL PLANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52944	10041-10003-03056	6750 W SUNSET BLVD	90028	13	147A185    92	5547021001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	ADDRESS	34.09769	-118.33815	CHANGE THE APPROVED PLAN. ADDED A PULL SECTION AND CIRCUITS. ((((((((((NEW RESTAURANT- CHICKEN FILLET)))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52945	18041-20000-17337	24052 W BESSEMER ST	91367	3	177B089   433	2045006014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Issued	05/10/2018 12:00:00 AM	ADDRESS	34.18133	-118.65127	Plan check for the addition of (1) Tesla PowerWall onto an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52946	19041-20000-21064	3408 S KEYSTONE AVE 1-33	90034	5	120B161   449	4314018017	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			06/04/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	02/04/2022 12:00:00 AM	ADDRESS	34.02642	-118.41139	Plan check for power and energy for new 1600 amp service, panels and equipments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52947	10041-20002-02461	12744 N SAN FERNANDO ROAD Bldg #4	91342	7	222B145   396	2506003010	M2-1	North Valley				1065.20	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM			PC Approved	11/18/2010 12:00:00 AM	ADDRESS	34.30155	-118.46112	Plan check revision to approved plans. Changes indicated Delta 10 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52948	15041-20000-39863	888 W WILSHIRE BLVD	90017	14	130-5A209 211	5144008017	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Expired	01/10/2018 12:00:00 AM	ADDRESS	34.04984	-118.25918	Plan check for t24 energy only.   TI to existing commercial building (restaurant). Adding new lighting including emergency.  2529 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52949	15041-20001-44041	1254 W YOSEMITE DR	90041	14	160-5A229 292	5480020009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.13323	-118.19322	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52950	14041-10000-34976	13294 N RALSTON AVE	91342	7	225B141   156	2501002052	[Q]MR1-1-K, [Q]P-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.31368	-118.47379	Full plan check for commercial building in change of use from manufacturing building to baking operation.note. Panel LE is existing but all load in the panel is new. Tittle 24 should be based on 2013 energy code.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52951	13041-10000-22207	100-800 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	Plan check for new power centers to supply new roadway lighting and ribbon lighting of LAX CTA - Phase II. Power centers are located outdoor and adjacent to Parking structure #1, 2, 5, and 7. Deferred approval for custom roadway light poles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52952	18041-10000-16231	12121 W WILSHIRE BLVD #910	90025	11	126B145   208	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.04386	-118.46816	PLAN CHECK FOR TITLE 24 ONLY FOR INTERIOR REMODEL TO THE (E) OFFICES LOCATED IN THE 9TH FLOOR OF A HIGH RISE BUILDING, ENLARGE (E) CONFERENCE ROOM, NEW STORAGE ROOM - TOTAL AFFECTED AREA = 1732 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52953	16041-10007-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.23567	-118.5584	This is plan check only for changes to approved set. Permit is covered under master. Changes is clouded/noted as Delta 31 on the plan, narrative of change is attached to the plan.Changes include added, remove, relocate, repurpose loads inside the units.<<PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE  APARTMENT WITH 215UNITS.   AND RESTAURANT/ RETAIL CORE & SHELL.  FOUR FLOORS OF RESIDENTIAL OVER TWO FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL. THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMP, 4000 AMP, AND 1600 AMP.  TOTAL AREA = 408,828 SQ. FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52954	16041-10000-22495	6901 S MCKINLEY AVE	90001	9	102B205   344	6007016029	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Closed	10/11/2016 12:00:00 AM	ADDRESS	33.97679	-118.26159	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (WAREHOUSE). SCOPE INCLUDES REPLACING THE HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTEDA AREA IS 9192 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52955	16041-10000-09552	900 S UNION AVE	90015	1	130-5A205 295	5137003004	C2-2	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	ADDRESS	34.05061	-118.27306	PC for enery only to a parking lot. Installing 2 new light posts. Total area: 18400. Note: Permit pulled under an express permit 15041-10000-37649	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52956	13041-20000-11854	1555 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	34.09923	-118.32707	NEW YOGA STUDIO. RELOCATION EQUIPMENT COUNT AS NEW INSTALLATION. RATED 600A. NEW CIRCUITS LIGHTING FIXTURES. PC FOR POWER AND ENERGY. LOW RISE BUILDING PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52957	14041-20000-17033	10351 W SANTA MONICA BLVD 2, 3, 4 Fl	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	PIN	34.0585564	-118.42324002	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY ONLY.  REPLACING LIGHTING FIXTURES ON 2,3,AND 4TH FLOOR.  NO NEW LOADS, ALL CIRCUITS ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52958	11041-10003-05846	4417 S STAUNTON AVE	90058	9	112-5A213 135	5106004006	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM			PC Approved	03/04/2013 12:00:00 AM	ADDRESS	34.00334	-118.24214	supplamental to original pc for t24 only. addition of outdoor lighting. pc for outdoor energy compliane. T.I.  EXISTING STORE.  INSPECTOR REQUESTED PLAN CHECK.  LIGHT FIXTURE CHANGES.  TITLE 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52959	18041-20001-38403	9524 N SHOSHONE AVE	91325	12	201B129   410	2755009011	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	34.24414	-118.5176	expeditepv1install roof mounted pv system sized 10.3KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52960	16041-10000-36115	2049 S CENTURY PARK EAST 500	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24, PC FOR ENERGY ONLY. INTERIOR RENOVATION OF EXISTING OFFICE SPACE ON THE 5TH FLOOR OF A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 21199 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52961	19041-20000-15551	11545 W OLYMPIC BLVD	90064	11	123B153   152	4260005017	C2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.03621	-118.44494	T24 ONLY PLAN CHECK FOR LIGHTS ONLY IN EXISTING COMMERCIAL MEDICAL OFFICE. TOTAL SQUARE FOOTAGE = 2,845SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52962	14041-10005-35068	1311 W SEPULVEDA BLVD	90501	15	045B193   791	7347018097	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	33.81492	-118.30044	PC FOR CHANGES TO APPROVED SET DUE TO INSPECTION. CHANGES INCLUDES REVISED  LIGHTING FIXTURES IN THE COMMON AREA  AND T-24 FORMS. TOTAL AFFECTED AREA 7701 SQ. FT . THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52963	16041-10000-44936	1561 W WASHINGTON BLVD	90007	1	126B197   662	5056023040	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.04017	-118.29084	PC for energy only; Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 18150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52964	16041-10000-08079	21 E THORNTON AVE 1-35	90291	11	109-5A143 411	4286023028	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Apartment			03/08/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	33.99248	-118.47759	PC FOR A FIRE ALARM SYSTEM. SCOPE INCLUDES UPGRADING A FIRE ALARM PANEL AND ADDING NEW FIRE ALARM DEVICES TO AN EXISTING 3 STORY APARTMENT BUILDING.  1 FA PANEL, 8 FA DEVICES, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52965	19041-10000-20525	251 S MCCADDEN PL	90004	4	135B185    66	5513028015	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.06945	-118.33731	PV1 - NEW 8.99KW ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOME WITH 29 PV MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52966	15041-20001-34574	1845 S PONTIUS AVE 3RD FLR	90025	5	126B153   198	4323026015	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.04443	-118.44248	01-28-16 Change to approved set of plans. Changes include additional lighting fixtures and area. Total new area: 558 sq ft. {{{{{{T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING FOR THE 3RD FLOOR. TOTAL AREA IS 480 SQ. FT.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52967	17041-10000-40225	158 E 66TH ST	90003	9	102B205    30	6011002016	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	33.97959	-118.2718	PC for new 5KW roof mounted solar system. Installing 21 modules with optimizers and one central inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52968	18041-20000-33760	4829 N FULTON AVE	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	12/17/2021 12:00:00 AM	ADDRESS	34.15876	-118.42353	new fire alarm system with 81 devices and (1) FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52969	19041-10000-29594	510 S BROADWAY	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	12/15/2020 12:00:00 AM	ADDRESS	34.04767	-118.25088	FULL PC FOR TENANT IMPROVEMENT OF FLOORS 2,4, AND 5 IN AN EXISING BLDG. THIS IS THE 5TH FLOOR OF THE SERIES. SERVICE SIZE IS 600A, 120/240,3PH,4W AND 400A,120/240,1PH, 3W. AREA OF SCOPE 6,265SF.BUILDING PERMIT NUMBER 19016-10000-22744	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52970	18041-10000-04753	7117 N VALJEAN AVE	91406	6	183B137   108	2224012034	[T][Q]MR1-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.19975	-118.48605	Energy plan check for a (N) 2- STORY WAREHOUSE ( 2425 SF )/ OFFICE ( 2186 SF ) BLDG. Scope include a new service of 400 Amp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52971	15041-10000-40830	12723 W WENTWORTH ST	91331	6	198B161   319	2629027017	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.23711	-118.41145	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE EXISTING HID LIGHITNG FIXTYRES AND REPLACE WITH NEW LEDS.  TOTAL SQUARE FOOTAGE 10944	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52972	17041-10000-35583	13027 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Issued	10/23/2017 12:00:00 AM	ADDRESS	34.18799	-118.41667	"Plan check for power and energy on a  first time tenant  ""UPS"". Total area: 1,411  sq ft."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52973	14041-20000-03188	109 N LAUREL AVE	90048	5	138B177   560	5511004009	R1-1	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Expired	03/02/2016 12:00:00 AM	ADDRESS	34.07465	-118.36488	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52974	18041-20000-34470	8985 W VENICE BLVD	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.02733	-118.39241	Installation of (7) private fleet EV chargers and associated 800A 277/480V distribution to existing 4000A  277/480V service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52975	19041-10000-15774	9805 N MASON AVE	91311	12	201B109   364	4378016028		North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	05/15/2019 12:00:00 AM	ADDRESS	34.24803	-118.5802	Full PC power and energy for site lighting , EV stations and sign (scope of work under phase 2 only). service is 2000A,208/120V, 3ph, 4 wire. area of scope 75,521SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52976	15041-20000-27195	838 E 6TH ST	90021	14	126A213   271	5147030062	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Expired	09/13/2017 12:00:00 AM	ADDRESS	34.03991	-118.24183	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,105 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52977	15041-20000-21386	1100 S GLENDON AVE Suite 1600	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.06074	-118.44418	Title 24 plan check only.  Total area = 9,000 sq. ft.  T.I. to existing hightise commercial office space.  New lighting only for suite 1600, including emergency lights and exit signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52978	15041-10000-01919	14006 W RIVERSIDE DR #22A	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Issued	04/01/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for T-24 only for T.I. remodel of existing retail space. Total area: 2257 SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52979	13041-20000-13507	1251 E OLYMPIC BLVD	90021	14	123A213    47	5146017010	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.03249	-118.24443	T24 FOR EXISTING SUBWAY RESTAURANT. 930 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52980	19041-10001-25593	11662 N RICASOLI WAY	91326	12	213B109   709	2701076071	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	34.28404	-118.58406	Plan check only.........(((Permit under original application.)))(((Plan check for a PV1 11.4kW AC / 10.8KW DC roof mounted system. Scope includes (1) inverter, (30) modules and optimizers interconnecting through the main serivce panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52981	15041-20000-14538	4124 N STANSBURY AVE	91423	4	165B153   976	2266026010	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Expired	07/26/2017 12:00:00 AM	ADDRESS	34.14515	-118.44095	"""$0 fees due to senate bill 1222""PV1. Install roof mounted PV system sized 24.7 kW. Interconnected with main service panel.  q  (115) Yingli YL250-P Modules(115) Enphase M215 Inverter"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52982	11041-10000-23625	600 W WORLD WAY Terminal 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	New conveyor motors for LAX Terminal 6  (Alaska Air Lines).  (Install conveyor motor loads to existing panels approved under 11041-10000-20814). Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52983	15041-10000-12226	811 W 7TH ST	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.04908	-118.25911	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW AND EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2800.  SCOPE OF WORK TO BE PERFORMED IN FLOORS 2,9,10,12 PLUS PENTHOUSE ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52984	16041-20000-08383	8336 W BEVERLY BLVD	90048	5	138B173   475	5511010005	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM			Corrections Issued	03/09/2016 12:00:00 AM	ADDRESS	34.0759	-118.37138	Plan check for energy only. TI to existing retail space. New lighting. 1,307sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52985	15041-10000-06762	11955 W BLUFF CREEK DR	90045	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	33.9836	-118.40144	Methane mitigation sysyetm for new two-story open parking garage. (49,000 sf for each story; total 98,000 sf).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52986	11041-20000-13109	600 W WORLD WAY T6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK T24 ENERGY (GENERAL LIGHTING/EMERGENCY) FOR COFFEE BEAN & TEA LEAF.  INTERIOR TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52987	17041-10001-06760	1101 S VERMONT AVE #102	90006	1	129B197   480	5078027037	C2-1, R4-1VL	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.05073	-118.29194	PC FOR CHANGES TO APPROVED SET UNDER DELTA 1. SCOPE INCLUDES CHANGES TO REFLECT FIXUTRE CHANGE AND UPDATING TITLE 24.THIS IS PLAN CHECK ONLY!!!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52988	12041-10000-04454	1162 N VIA DE LA PAZ	90272	11	129B125   278	4423001002	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	05/31/2012 12:00:00 AM	ADDRESS	34.05084	-118.52603	Plan check for 7.22KW roof mounted for Photovoltaic system for single family dwelling. Modules connected DC to DC vBoost device.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52989	18041-10000-36654	5971 S MAIN ST	90003	9	105B201   542	6005015031	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.01	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	33.98545	-118.27419	PLAN CHECK FOR POWER AND ENERGY FOR - PROPOSED DENTIST OFFICE TENANT IMPROVEMENT; WORK TO INCLUDE PARTIAL NEW CEILING, NEW NON BEARING PARTITIONS - ALL CHANGES SHOWN ON PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52990	14041-10000-14880	12642 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	33.97765	-118.41437	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52991	13041-10000-05746	380 WORLD WAY Space T72	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 541 SQFT  TENENAT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE ( Drink LA). T72  level 5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
52992	19041-10000-53602												Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			PC Approved	12/27/2019 12:00:00 AM					N	N	Express Permit	06/10/2024 12:00:00 AM
52993	18041-20000-21166	15303 W VENTURA BLVD Suie 700	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.15413	-118.46661	Plan check for Title 24 only in existing sapce office remodel lighting circuits Total area: 18,082 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52994	18041-10000-35098	14439 W VAN NUYS BLVD	91331	6	201B149   288	2647028015	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.24797	-118.44724	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
52995	15041-10000-00619	13907 W DAVENTRY ST	91331	7	207B153   325	2618003020	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2015 12:00:00 AM			PC Approved	01/30/2015 12:00:00 AM	ADDRESS	34.26558	-118.43589	Installation of new roof mounted solar PV array.  Total system size = 12 kVacRestamp for permit issued 14041-10000-23566 (original stamped set lost)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
52996	15041-20000-19298	7610 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.20894	-118.46479	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
52997	14041-10000-15572	1111 S CENTRAL AVE	90021	14	123A213   216	5132015048	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.03063	-118.2452	Title 24 plan check only.  Total area = 5412 sq. ft.Remove HID light fixture and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52998	15041-10000-05559	7782 N SAN FERNANDO ROAD	91352	2	189B177   432	2405001005	[Q]CM-1, [T][Q]MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.21264	-118.35851	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 4400 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
52999	16041-20000-23827	6420 W WILSHIRE BLVD 4th floor-Terrace	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for Title 24 only outdoor area terrace on 4th floor. Total area: 2,053 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53000	16041-10000-38834	750 E MANCHESTER AVE	90002	9	097-5A207 297	6042002003	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	33.95994	-118.26142	Plan check for power only for service upgrade 600A.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53001	16041-10002-41752	752 E WASHINGTON BLVD	90021	9	121-5A209 195	5131006011	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	34.02678	-118.25595	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1. REVISED LIGHTING PLAN TO SHOW DAYLIGHT AREA AND SHOW LOCATIONS OF PHOTOCELLS FOR DAYLIGHT HARVESTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53002	12041-10001-02033	10100 S AVIATION BLVD	90045	11	090B173   144	4129029013	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM			Re-Activate Application	09/12/2012 12:00:00 AM	ADDRESS	33.94466	-118.37822	REVISED SINGLE LINE TO SHOW THAT SERVICE  AMPERE RATING IS 600A NOT 800A AND REVISED SOME PANEL LOADS(((((((((New commercial kitchen space, change of use.  New 800A Switchboard and 4 new subpanels, new circuits and loads.  11,450 sq ft of T-24.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53003	16041-20001-44973	3376 S MOTOR AVE	90034	5	120B161   169	4314023013	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.0281	-118.40963	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on a commercial building.Interconnect with a 400A MSP. 10kW ungrounded system. (36) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53004	14041-20000-20051	7354 N HESPERIA AVE	91335	3	186B125   708	2121003022	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Closed	03/10/2016 12:00:00 AM	ADDRESS	34.20452	-118.52608	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD. Interconnect with MSP. System size: 7.6kW(2) SolarEdge SE3800A-US-ZB-U transformerless inverters(34) Trina Solar #TSM-255PA05.18 pv modules(34) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53005	14041-20000-01168	7327 W ELMO ST	91042	7	202-5A199  17	2568009028	MR1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.25131	-118.29198	pv2 commercial system. total system size 20kw ac using 2 transformerless inverters nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53006	11041-10000-02384	400 S HOPE ST 8th & 9th-floors	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM			PC Approved	03/17/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	alterations in offices on the 8th & 9th floors: the outr offices have the luminaures replced with those of lower wattages other luminaires in open offices are new; new panelboards. title 24 only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53007	10041-10000-18578	8480 W BEVERLY BLVD # A101.2	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	03/15/2012 12:00:00 AM		Permit Finaled	05/01/2012 12:00:00 AM	ADDRESS	34.07577	-118.37599	New Marshall retail store in existing at the Beverly Connection	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53008	18041-10000-09308	2515 W BEVERLY BLVD	90057	13	136-5A203 121	5157009027	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.06907	-118.27536	FULL PLAN CHECK, CHANGE OF USE FROM OFFICE TO CHARTER SCHOOL; NEW 800A SERVICE, (12) PANELBOARDS, TOTAL AREA 30,825 SQ.FT (INDOOR+OUTDOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53009	17041-10000-13045	21000 W PLUMMER ST	91311	12	204B133   217	2685002016	C2-1VL, [T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch, Granada Hills - Knollwood	Chatsworth, North Hills West		1133.03	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.24253	-118.59179	PC for energy only, Outdoor Title-24.  Removing HID fixtures and replacing with New LED. area: 69,275.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53010	14041-20000-05106	15945 W VENTURA BLVD	91436	5	168B141   542	2261021101	C2-1L, P-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.15624	-118.48082	T.I. to existing building (Marshall store) in dressing area only.  Install lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53011	16041-20000-22711	5700 W WILSHIRE BLVD	90036	4, 8	135B177   580	5089008031	C2-1VL, QC4-2-CDO	Central, South Los Angeles	South Los Angeles, Wilshire	Empowerment Congress Southwest Area, Mid City West		2163.00, 2384.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.06218	-118.35303	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MAIN LOBBY AREA. 2522 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53012	12041-10000-04972	7753 DENSMORE BLVD	91406	1	129A205   247	5137011005	[Q]C2-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	PIN	34.04743442	-118.27091233	TI in an existing office. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53013	15041-20001-39236	1446 N DEVLIN DR	90069	4	147B169   855	5560001020	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM			PC Approved	01/25/2016 12:00:00 AM	ADDRESS	34.09575	-118.38711	01/25/2016 Changes to an approved set of plans. Changes have been made to the single-line diagram to show the addition of a performance meter.*****Previous Work Description*****$0 permit fee is due to Senate Bill SB-1222. PV1, roof mounted solar panel, interconnected with 600A MSP.  21.5 kW AC system(86) modules: SW280MONO(86) microinverters: Enphase M250-72-2LN-S2(1) load center 125	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53014	18041-20000-17829	5418 S MCCONNELL AVE	90066	11	102B157    32	4211009018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Issued	05/21/2018 12:00:00 AM	ADDRESS	33.97832	-118.4197	Plan check for Title 24 energy only T.I. office wearhouse. Total area: 12,798 sq ft.Newly connected load is less than 400A. B#18016-20000-10142	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53015	14041-20000-05228	12805 W NORTH SEAGLASS CIR	90094	11	102B161  1224	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	33.97505	-118.41793	ROOF-MOUNTED, PV1 TRANSFORMERLESS SYSTEM.  TOTAL SYSTEM SIZE 2.25 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53016	17041-10000-40223	1206-1210 S MARIPOSA AVE	90006	1	129B197   839	5078034025	R3-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			11/07/2017 12:00:00 AM			Re-Activate Permit	03/27/2019 12:00:00 AM	ADDRESS	34.04884	-118.29879	PROPOSED ADDITION OF A 3 STORY,  7 UNIT, TYPE VA  APARTMENT  W/GROUND LEVEL PARKING AND UPGRADE EXISTING DWELLINGS TO CODE. THERE ARE TWO EXISTING BUILDINGS (SFD AND DUPLEX) THAT WILL BE CONNECTED WITHE THE PROPOSED ADD'N TO CREATE A 10 UNIT APARTMENT. THE ENTIRE NEW BLDG WILL BE OF TYPE VA CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53017	16041-10001-40948	868 W MT WASHINGTON DR	90065	1	148-5A221 127	5464014034	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.10036	-118.22108	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53018	13041-10000-31237	1038-1048 S MARIPOSA AVE	90006	1	129B197   387	5078016016	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			11/07/2013 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.05151	-118.2988	"FULL POWER PLAN CHECK FOR A NEW 32 UNIT APARTMENT BUILDING. PLAN CHECK IS FOR POWER AND ENERGY. NEW 1600A 120/208 3PH 4WIRE ""MSA"". TOTAL ILLUMINATED AREA TO BE 38,434 SQ FT (INDOOR + OUTDOOR). 5 FLOORS FROM GND, APPROXIMATELY 9 DIFFERENT UNIT TYPES PER ARCHITECT. (7) 1200A SWITCHBOARD SECTIONS & (32) SFD SMOKE DETECTORS WERE ACCOUNTED FOR AND CHARGED."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53019	15041-10000-22296	15915 W INDEX ST	91344	12	210B141    80	2666013013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.27564	-118.47863	PV1, INSTALL 8.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON ONE SINGLE FAMILY HOUSE.(29) MODULES: LG280S1C-B3(1) INVERTER: SMA AMERICA-SB7000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53020	16041-20000-16247	10100 W SANTA MONICA BLVD STE 1000	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1623.  SCOPE TO BE PERFORMED IN THE 10 FLOOR SUITE 1000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53021	14041-10000-28817	12154 W MONTAGUE ST	91331	7	204B165    89	2537018027	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.25712	-118.39806	PC FOR POWER AND ENERGY. COMMERCIAL TI TO EXISTING OFFICE SPACE INCLUDING OFFICES, BREAK ROOMS AND RESTROOMS. TOTAL AREA 30415 SQ FT. See additional comments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53022	18041-20000-19041	5135 W ADAMS BLVD	90016	10	123B177   883	5049009050	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.03265	-118.35318	Plan check for a fire alarm system for a 3-story apartment building. Fire alarm consists of (1) FACP, (1) annunicator, (2) RPSs, and (40) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53023	12041-10001-13375	505 S VIRGIL AVE	90020	13	135B197   873	5077004028	R4P-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.0649	-118.28724	"((DELTA 3 CHANGES MADE TO PREVIOUSLY APPROVED PLANS (BY P.U.). CHANGES MADE TO FLOOR PLAN. ADDITIONAL 3 PANELS W/ NEW CIRCUITS. METHANE ZONE))PLAN CHECK POWER AND ENERGY FOR EXISTING THREE STORY BUILDING.  CHANGE OF USE TO MEDICAL BUILDING. TWO  2000A SERVICES SUPPLYING BUILDING IN METHANE ZONE. ""COMPLY WITH DEPARTMENT ORDER effective date11/30/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53024	14041-20001-06224	2421 N NALIN DR	90077	5	156B145   353	4378002021	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM			PC Approved	03/21/2014 12:00:00 AM	ADDRESS	34.11997	-118.46656	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM .TOTAL SYSTEM SIZE 5.0KWAC WTIH SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53025	13041-10000-00798	770 W WILSHIRE BLVD 6th FLOOR	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/11/2013 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.04914	-118.25811	RETROFITTING EXISTING 136 2X4 FIXTURES WITH LED RETROFIT KIT ON 6 th FLOOR OF 9 FLOOR BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53026	14041-10000-12338	4021 W ROSEWOOD AVE	90004	13	141B197  1101	5520006012	(Q)CR-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.07919	-118.29256	permit to be pulled at EPC counter only. Plan check for energy only. Emergency lights installed,  lowrise building. TI TO (E) AMERICAN CAREER COLLEGE 3RD FLOOR. No patient care per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53027	16041-20001-39871	20320 W SCHOENBORN ST	91306	3	192B113   505	2781028043	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.22117	-118.57609	11/29/2016 Plan check for the addition of a PV1 roof-mounted system onto an existing PV system. System addition size is 3.8 kWac and consists of (1) inverter, (12) modules, and (1) load center. Total system size is 6.4 kWac.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53028	14041-20000-30174	12000 S VISTA DEL MAR Learning-Center BLD	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	PIN	33.92817449	-118.43220714	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING POWER EQUIPMENT.  9267 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53029	18041-20000-05983	3470 S TROUSDALE PKWY	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.02202	-118.28393	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 7,920 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53030	16041-10004-20314	19600 W PLUMMER ST STE 300	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.2426	-118.5602	Changes to approved set of plans Optometrics office. Removing lighting lighting fixtures and changing model types. Uptdaded Title 24. All changes are clouded under delta 2.  Total area: 1,821.Note: Permit is paid under PCIS#16041-10002-20314	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53031	12041-20000-07653	4500 N GABLE DR	91316	5	165B125    24	2184016007	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2012 12:00:00 AM			Verifications in Progress	06/21/2012 12:00:00 AM	ADDRESS	34.15215	-118.5283	Roof mounted 8.64KW PV system with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53032	19041-20001-51365	23501 W ARMINTA ST	91304	12	189B093   456	2020004040	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM			PC Approved	12/31/2019 12:00:00 AM	ADDRESS	34.21339	-118.63867	12/31/19CHANGES TO APPROVED SET CHANGES TO REMOVE THE AC DISCONNECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53033	15041-10000-04583	216 N ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.05027	-118.23789	Power plan check only.  Installation of new medium voltage temporary power substation for the regional connector transit corridor light rail project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53034	14041-10000-00641	161 N ISLAND AVE	90744	15	027B205   441	7440006911	PF-1D	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	33.77052	-118.2659	New LADWP Administrative Office (5,513 sf) and 2,160 sf maintenance building.  New 500A 480/277V service and distribution equipment.  Methane zone. Plans were expedited and paid  under submittal-2 fees period on same application in the amount of $882.21	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53035	16041-10001-35118	10928 N BATON ROUGE AVE	91326	12	210B121   694	2718016001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.26882	-118.55104	EXPEDITE PER APPLICANT REQUEST.(((((PV1. NEW SOLAR SYSTEM FOR EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.42KWdc / 11.52KWac.(36)AC MODULES-SPR-X21-345-C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53036	19041-20000-05230	12707 W HATTERAS ST	91607	2	174B161   147	2341011017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.17587	-118.40986	Plan check for a PV1 roof-mounted PV system. System size is 10.56 kWdc and consists of (1) 11.4 kWac rated inverter and (32) modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53037	16041-10001-31416			15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	PIN	33.76073675	-118.29107835	expedite feesPV FOR ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE 1920AC USING 80KW INVERTERS - TOTAL OF 24ALSO USING 6048 PV MODULESPV SYSTEM IS FEED IN TARRIF. INTERCONNECTION IS DIRECTLY TO UTILITY. PV ONLY SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53038	15041-10002-27087	1329 E 3RD ST	90033	14	127-5A219  42	5172010003	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.04513	-118.22559	04/27/16CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1. (((PC for enrgy and emergency lighting. TI to an existing bldg adding new lighting new controls to new panels, newly connected load less than 400 amps. Total sq ft = 4841.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53039	17041-20001-16584	18549 W ST MORITZ DR	91356	3	165B125   374	2184050023	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.14541	-118.53674	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53040	16041-10000-38960	15411 S FIGUEROA ST	90248	15	072B201   156	6120027007	M1-1VL, P-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	33.89139	-118.28317	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53041	16041-20000-26493	9301 N TAMPA AVE 46A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is an existing tenant space within commercial building. Project scope is a tenant improvement. Total lighting area = 994 sq. ft.Note: Building application has been created under 16016-20000-17325	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53042	14041-10000-35279	145 N LA BREA AVE E	90036	5	138B181   632	5513002010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.07488	-118.34438	T.I. to convert art gallery into spa/massage parlor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53043	18041-10000-19529	16933 W PARTHENIA ST	91343	12	195B133   439	2688041039	C1-1VL, C2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.22863	-118.50131	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53044	15041-10000-05351	18060 W CHATSWORTH ST 1-6	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.26446	-118.52593	Fire alarm system upgrade for existing building.  48 total devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53045	14041-20000-14903	20532 W RHODA ST	91367	3	174B109   333	2151023014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.17378	-118.58089	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. USING 22 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53046	19041-10000-07643	244 S SAN PEDRO ST	90012	14	129A213   168	5161020019	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	34.04787	-118.24192	T-24, PC FOR ENERGY ONLY. INTERIOR IMPROVEMENT OF ELEVATOR VESTIBULE, RESTROOM AND MULTIFUNCTION SPACE WITH PANTRY ON LOWER FLOOR. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND NEW PANELBOARDS. TOTAL AFFECTED AREA IS 5888 SQ. FT. B19016-10000-06000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53047	13041-10000-18320	425 S SOTO ST	90033	14	126A223    76	5183014036	C2-1, P-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Expired	08/05/2015 12:00:00 AM	ADDRESS	34.0398	-118.21254	UPGRADING AN EXISTING MONITORING FIRE ALARM SYSTEM IN A COMMERCIAL AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53048	18041-10000-11875	543 S BROADWAY	90013	14	129A211   125	5149033002	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.04718	-118.25186	PLAN CHECK FOR TITLE 24 ONLY FOR CHANGE OF USE FROM RETAIL TO TAKE-OUT RESTAURANT(DONUT SHOP - 19.5' x 153.86'). TOTAL CONNECTED LOAD <400A FEEDING FROM 2 DIFFERENT SERVICES. TOTAL TITLE 24 AREA = 2545 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53049	14041-20000-11574	6623 W MELROSE AVE	90038	5	141B185   553	5524012022	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.08359	-118.33946	Interior remodel for first floor restaurant of three story office building -- New 800 amp service with new panelboards. Reconnect existing 2nd floor panels to new service. New wiring for receptacles and appliances.  Plan check for power and energy.  \INT. T.I. TO EX RESTAURANT CORE & SHELL BLDG UNDER 11016-10005-19227. THIS PERMIT TO INCLUDE ONSITE SALES AND CONSUMPTION OF ALCOHOLIC BEVERAGES PER ZA2013-0566(CUB)(CU) & UNROOFED OUTDOOR SEATING (12 SEATS). SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53050	11041-10000-04523	4757 N LAUREL CANYON BLVD	91607	2	168B165   567	2356037045	RD1.5-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	05/25/2012 12:00:00 AM	ADDRESS	34.15728	-118.39672	New car wash at minimart.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53051	19041-20000-02071	24341 W STONE BEND LANE	91304	12	192B089   178	2017038010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.22012	-118.65555	PV1.  Install 7.56 kW roof mounted grid tied PV array.  (24) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53052	16041-10001-18950	10519-10519 1/2 N SAMOA AVE	91042	7	207B197  1541	2566007033	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.25996	-118.28703	07/14/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES TO REFLECT WHAT IS ON THE FIELD. CHANGES INCLUDE THE TRENCH LENGTH FROM 60FT TO 100FT.NOTE: PERMIT PAID UNDER PCIS#16041-10000-18950 ((((PV1, INSTALL A 7.6 KW AC ROOF-MOUNTED SOLAR SYSTEM ON AN EXISTING SINGLE FAMILY HOUSE.(40) MODULES; SOLARCITY STANDARD 265W(1) INVERTER: FRONIUS PRIMO 7.6 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53053	14041-10001-07076	1835 N BOLKER PL	90731	15	024B197   111	7442020004	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	33.76288	-118.29682	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL  A 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800-US-ZB-U(17)MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53054	14041-20000-34872	4420 N ALFARENA PL	91356	3	165B121   109	2177021004	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.15156	-118.5446	PV1. ROOF MOUNTED PV SYSTEM SIZED 11.4 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(49) SOLAR WROLD 275W MODULES(49) SOLAR EDGE P300 POWER OPTIMIZERS(1) SOLAR EDGE SE11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53055	14041-20000-15700	11764 W IDAHO AVE 1-8	90025	11	126B149   575	4262013008	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			06/12/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.0417	-118.4563	new 8 unit apartment. 4 stories. connected to 3 phase 4 wire delta. fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53056	13041-10000-04928	1375 N WESTERN AVE	90028	13	147A193   196	5544030055	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	PIN	34.09622604	-118.30960264	PC IS FOR T24 ENERGY. BUILDING ADDITION AND RENOVATION FOR AN EXISTING RESTAURANT; EXPAND RESTAURANT INTO (E) POST OFFICE (CHANGE OF USE FROM POST OFFICE TO RESTAURANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53057	19041-10000-05044	1062 N SWARTHMORE AVE 2-101	90272	11	129B125   462	4423016***	[Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.04804	-118.52468	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL TOTAL EFFECTED AREA 1640 SQFT.  FULL PLAN CHECK APPLICATION UNDER 18041-10000-41478.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53058	13041-10000-08010	1300 W 177TH ST F	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	33.87031	-118.29542	T24 for new juvenile impact program shelter.  1776 sq ft.  Permit to be pulled at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53059	14041-10000-33728	2000 S AVENUE OF THE STARS	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05868	-118.41546	Energy plan check for a high rise building T.I (elevator lobby and stair only from top to ground level)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53060	15041-10000-03340	9758 N BURNET AVE	91343	7	201B145   360	2656007007	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.24814	-118.46293	Installation of roof mounted solar PV array on existing single family dwelling.  Total system size = 8.4 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53061	19041-30000-36012	110 E NAVY ST	90291	11	111B141   545	4286017***	(Q)C4-2D	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			PC Approved	09/10/2019 12:00:00 AM	ADDRESS	33.9972	-118.47917	PLAN CHECK FOR ENERGY ONLY, TENANT IMPROVEMENT TO RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1050 OUTDOOR AND 4395.Withdrawn by Jeff Salman Authororized Kristopher Keith	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53062	14041-20000-14564	5601 W WILSHIRE BLVD	90036	4	135B181   891	5508013034	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.06252	-118.35061	T.I. to existing grocery store (Ralphs).  Install lighting in the coffee vendor kiosk.  Plan check for energy only.Note: The original approved plans were lost.  Lost plans approved under 14041-20000-09165.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53063	18041-30000-35685	10100 W SANTA MONICA BLVD CAFE-SPC.100	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM			PC Info Complete	09/18/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	PLAN CHECK FOR T24 ONLY, TI ON (E) CAFE SPACE 100, TOTAL AREA UNDER THE SOW: 1,206 SQ.FT. SCOPE ALSO INCLUDE REPLACING TRANSFORMER AND EMERGENCY PANEL LIKE FOR LIKE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53064	15041-20000-28316	465 N FAIRFAX AVE	90036	5	141B177  1183	5527031014	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Closed	02/12/2024 12:00:00 AM	ADDRESS	34.07996	-118.36169	Plan check for power and Title-24.  Total area = 1,450 sq. ft. (indoor) + 5,307 sq. ft. (outdoor)  New electrical distribution system for new restaraunt.  600 A service with 3 subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53065	18041-30000-45397	17330 W VENTURA BLVD	91316	5	168B133    18	2290001002	QC4-1VL, QP-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.16085	-118.511	PC FOR TITLE 24  ENERGY ONLY. TI FOR change of use from office to ice cream parlor with sit down dining. Since it was a change of use full plan check was performed M.ZSCOPE INCLUDES NEW PANEL, CIRUCITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 1076 SQ.FT B#18016-30000-38282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53066	19041-30000-15230	5637 W LEXINGTON AVE	90038	13	144B193   363	5536004037	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Issued	04/25/2019 12:00:00 AM	ADDRESS	34.09289	-118.31218	Plan check for a fire alarm system for a 3-story, 27-unit apartment building. Fire alarm consists of (1) FACP and (144) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53067	18041-10000-07194	5700 N FIGUEROA ST	90042	1	151-5A229 252	5492002029	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.1096	-118.19241	PC for T24 only for replacement of indoor and outdoor existing fixtures with LED luminaires for Chase bank. Egress lighting is not part of the scope. Total area Indoor and outdoor is 7989sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53068	17041-10000-02246	307 S OCCIDENTAL BLVD	90057	1	136-5A201 221	5155009042	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.0675	-118.28255	PC for outdoor tile 24. Remove HID and replace with new LED fixtures. Total area: 6,700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53069	18041-10000-20515	226 E 1ST ST	90012	14	130-5A213 106	5161016007	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.05086	-118.24181	Energy plan check for a change of use from Retail to Restaurant. Scope includes new lighting and equipment with a total T24 area is 879 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53070	19041-20000-51712	1305 N SYCAMORE AVE	90028	4	144B181   110	5548022040	R3-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			12/16/2019 12:00:00 AM			Corrections Issued	03/15/2023 12:00:00 AM	ADDRESS	34.09459	-118.34302	Plan check for power and energy, 800A Service120/240 3 phase high leg. Total area:11,229 sq ft.  Verify Building permit. Building work description:****************************13 units apartment building****************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53071	19041-20001-35584	11552 W CANTLAY ST	91605	2	186B169   980	2316029008	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.20241	-118.38422	09-19-2019 Changes to an approved set of plan, Changes incude reduce number of PV Modules and Microinverters to 33 PV Modules and 33 microinverters and new PV system size: 11.055KW DC, 9.570KW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53072	14041-20000-03165	1217 N GARBO LN	90038	4	144B185  1345	5532004038	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	PIN	34.09303245	-118.3366744	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING SINGLE TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 6 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53073	13041-10001-34456	1133 S LONGWOOD AVE	90019	10	132B185   865	5084023036	R2-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.05474	-118.33956	Expedited RSES lan check per applicant request.{{PV1, Install a 4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53074	11041-20000-21773	10940 W WILSHIRE BLVD Ste 1050	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM			PC Approved	10/12/2011 12:00:00 AM	ADDRESS	34.05822	-118.4452	T.I.  Remodel of the light fixtures in Suite # 1050.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53075	10041-10000-04222	725 S FIGUEROA ST 9TH FL	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.04886	-118.26071	TENANT IMPROVEMENT IN THE REST ROOMS ON THE 9TH  FLOORPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53076	17041-10000-17584	14535 W HAMLIN ST	91411	6	180B149   577	2236015015	[Q]CR-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.18885	-118.45005	Title 24 plan check.  Change of use from office to dental.  Two new subpanels with lighting and receptacles.  Total area = 2,201 sq. ft.       Building permit #17016-10000-13928	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53077	15041-10000-03386	1732 N NEPTUNE AVE	90744	15	036B205    30	7421002005	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	33.79818	-118.27015	"Plan check for PV roof mounted 3.8KW with 1 inverter and 12 modules.Reason submit over the counter: Online system does not accept ""B"" license for Solar"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53078	15041-20000-37503	7400 N COLDWATER CANYON AVE	91605	2	186B161   521	2324001011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.20498	-118.41362	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a renovation to fire-damaged areas (replacement of light fixtures on existing circuits). Total lighting area = 488 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53079	17041-20000-08122	16244 W DORILEE LANE	91436	5	159B141   327	2293013020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.13208	-118.48479	pv1install roof mounted pv system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53080	18041-20000-20985	541 S SPRING ST 129	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Approved	06/06/2018 12:00:00 AM	ADDRESS	34.04657	-118.2507	PLAN CHECK FOR TITLE 24 ONLY FOR CHANGE OF USE FROM (E) RETAIL TO RESTURANT. CONVERSION OF (E) 750 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53081	15041-10000-07599	8040 N SAN FERNANDO ROAD	91352	2	189B177   955	2407025008	[Q]MR1-1-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.21721	-118.36523	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACING HID LIGHTING TO LEDS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 4279	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53082	15041-10001-16514	6411 W IMPERIAL HWY	90045	11	087B165    12	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Closed	01/23/2018 12:00:00 AM	ADDRESS	33.93238	-118.3989	Modification to approved set.  Additional 5 devices added to scope of work.  (((New fire alarm system for a single story commercial building with (1) fire alarm panel, (2) power supplies and (45) fire alarm devices.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53083	14041-20000-11153	6600 N TOPANGA CANYON BLVD # 1084	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. EXISTING RETAIL. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 4600 SQ FT. USING TAILORED METHOD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53084	17041-10001-01942	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	02/22/2018 12:00:00 AM		Issued	02/22/2018 12:00:00 AM	ADDRESS	34.18684	-118.3977	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES CLOUDED UNDER DELTA 2 & 3. CHANGES INCLUDE REVISING AVAILABLE FAULT CURRENT TO DISTRIBUTION EQUIPMENT, REVISING AIC RATINGS, REVISING PANEL SCHEDULES, REVISING LIGHTING FLOOR PLANS, AND REVISING TITLE 24 CALCULATIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53085	15041-10000-27351	3607 W MONT CLAIR ST	90018	10	123B189  1046	5051017012	R1-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.02976	-118.32385	PV1.  Install roof-mounted solar, interconnect with main service panel.  Sytem size: 2.805 kW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53086	19041-20000-01361	555 S FLOWER ST 40TH FL	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for Title 24 only in existing high-rise building elevator  lobby and restroom. Total area: 1589 sq ft. B#18016-10000-35393RENOVATION OF EXISTING ELEVATOR LOBBY AND RESTROOMS FOR EXISTING OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53087	15041-20001-25056	18124 W CHARDON CIR	91316	5	165B125   165	2184031030	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	34.15004	-118.52891	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (4) inverters, (90) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53088	19041-10000-45703	5625 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	33.93197	-118.382	PLAN CHECK FOR ENERGY ONLY (T-24). TOTAL AFFECTIVE AREA  2856 SQ/FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53089	19041-20000-05455	24209 S STERLING RANCH ROAD	91304	12	192B089   197	2017039008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.21965	-118.65435	PV1.  Install 2.835 kW roof mounted grid tied PV system.  (9) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53090	18041-10000-46887	1901 S AVENUE OF THE STARS 1400	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Issued	12/12/2018 12:00:00 AM	ADDRESS	34.05949	-118.41705	T-24 Only, INTERIOR OFFICE TI TO REMOVE AND ADD NON BEARING WALL TO CREATE (N) OFFICE SPACES. Scope includes new lights and receptacles. Total affected area is 8614 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53091	14041-10000-11960	380 WORLD WAY T-73 &-T74	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Install illuminated signage not visible from ROW.( Four identicl signs) T-73 & T74.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53092	16041-30000-08103	350 S GRAND AVE #2300	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for Title 24 in T.I. existing high-rise. Total area: 1,915 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53093	15041-10000-07133	10323 W LORENZO DR	90064	5	126B161   195	4308011034	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			Reviewed by Supervisor	03/18/2015 12:00:00 AM	ADDRESS	34.04039	-118.40725	PV1, INSTALL 6 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2 STORY  DWELLING. INTERCONNECT WITH MAIN SERVICE PANEL. (32) MODULES: YINGLI YL250P-29B(1) INVERTER: ABB PV1-6000-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53094	12041-20000-24452	8226 W 3RD ST	90048	5	138B173   918	5511030032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	ADDRESS	34.07239	-118.36886	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53095	16041-30000-01492	10969 W ROCHESTER AVE 1-38	90024	5	132B153   783	4324006040	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.05576	-118.44483	Replace FACP in existing 31 unit 4 story apartment building.  Elevator modernization including recall relays, smoke detectors, and heat detectors.  7 new devices total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53096	17041-20000-09083	12700 W VAN NUYS BLVD bldg 21,22	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM			Reviewed by Supervisor	04/13/2017 12:00:00 AM	ADDRESS	34.27528	-118.4092	pv2 ~~ install roof mounted pv system (ACM) sized 17.5kw AC, (66) modules, (34 ACM)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53097	13041-10000-32614	800-820 S FLOWER ST	90017	14	129A209   156	5144020040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Expired	12/29/2015 12:00:00 AM	ADDRESS	34.04702	-118.26009	T24 ENERGY FOR FACADE LIGHTING. 810-820 FLOWER BUILDING.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53098	19041-20000-35177	24250 W MARIANO ST PV1	91367	3	171B089   229	2047016020	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.16604	-118.6537	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.24 KW DC/11.082 KW AC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH MICROINVERTERSAND A PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53099	16041-10001-01169	3705 W SUNSET BLVD	90026	13	145-5A203 457	5429021034	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.09079	-118.27782	2/19/16: supplemental PC Only, added 6 outdoor lights using an (E) branch circuit. Revised T-24 LTO form only. Permit under: 15041-10000-41741, and 15041-10000-42402Change of use from Retail to Restaurant. All electrical equipments are existing. This is PC only for T-24 only. Total area: 5192 sq.ft (indoor+non sale canopy)Permit under: 15041-10000-41741, and 15041-10000-42402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53100	14041-20000-17576	8328 N DE SOTO AVE	91304	3	192B109   684	2780005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Winnetka		1132.34	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.22068	-118.58831	Remodel of (E) commercial single-story building for laundromat.  New 1000A 120/208V service and service equipment.Applicant to submit panel schedules before assignment.  Fees to be readjusted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53101	14041-10000-05509	1700 N INDIANA ST	90063	14	133-5A229  14	5224007002	M3-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM			PC Info Complete	02/28/2014 12:00:00 AM	ADDRESS	34.06191	-118.19249	PLANCHECK FOR POWER PER INSPECTORS REQUEST DUE TO HAZARDOUS LOCATION ( PROPANE). WIRING AND CONDUIT INSTALLATION FOR THE  PROPANE TANK. PERMIT PREVIOUSLY PULLED UNDER 13041-10000-31734.  Equip located in hazardous area is approved for the classsification.   Deal off is provided on both sides of the connections.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53102	14041-20000-01872	1768 S HAYWORTH AVE	90035	10	126B173   264	5066018017	R1-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.0439	-118.36982	pv1 single family dwelling. total system size 5kw ac using 20 modules. transformerless inverter with power optmizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53103	13041-10001-09207	10635 N IRMA AVE	91042	2	207A195   188	2557024045	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.26243	-118.30087	changes to approved set of plans. REC250 to ET Solar: ET-P660255 255W. Fees charged per applicant request. PV1 4.32kwAC MICRO INVERTER 2 STORY HOUSE. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53104	15041-10000-31376	216 N GRAND AVE	90731	15	018B197   820	7448032026	R2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	33.74455	-118.28995	PV2, INSTALL NEW 3.71 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(14) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53105	18041-20000-24103	5407 W SIERRA VISTA AVE	90038	13	144B193   882	5536019025	C4-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Apartment			06/27/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.08965	-118.30959	Plan check for power only. Project site is an existing apartment building. Project scope is a service upgrade to 600-amps. All tenant panels to be re-fed and existing to remain. No new loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53106	10041-10000-03249	7333 W WORLD WAY 4th FL	90045	11	090B161    67	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/24/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	PIN	33.94534804	-118.41786236	TI for offices on the 4th floor of the existing LAWA Admin Building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53107	13041-20000-21426	6911 N PETIT AVE	91406	6	183B137   342	2225013014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.19601	-118.4972	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING 26 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53108	15041-10001-36182	764 N TERRACE 49	90042	1	153A223   397	5471015024	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.11165	-118.20945	changes to approved set of plans. relocated inverter into garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53109	10041-10000-20501	16208 W PARTHENIA ST	91343	12	195B137   957	2689024023	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	05/13/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.22816	-118.48611	EXTENSION OF EXISTING FUELING CANOPY AND ADDING 2 NEW DISPENSERS ; WIRING IN HAZARDOUS AREAS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53110	15041-10000-15719	1234 S WESTERN AVE	90006	10	129B193  1106	5080011002	C2-1	Central	Wilshire			2132.02	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			Reviewed by Supervisor	06/29/2015 12:00:00 AM	ADDRESS	34.04833	-118.30885	TI TO AN (E) BUILDING, CHANGE OF USE FROM RETAIL TO FOOD LAB. ADDING NEW LIGHTING AND NEW 600 AMP SERVICE. PC FOR POWER AND ENERGY. TOTAL SQ. FT. 1950 .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53111	15041-20002-10430	1159 N SOMERA ROAD	90077	5	144B145    36	4369031030	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.09426	-118.45845	01/31/2017 Changes to an approved set of plans. Changes have been clouded. Changes have been made to the location of electrical equipment. Inverter is now located at the PV array. *****Previous Work Description*****Plans lost per applicant.  Recheck and restamp of plan set.  (((Plan check for PV system ground mounted 7.28kW system with 26 modules(SunModule Plus SW280 Mono) and 1 inverter(Fronius Promo 7.6-1))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53112	19041-10001-46425	5500 W OLYMPIC BLVD	90036	4	132B181   683	5085010001	R3-1-O-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM			PC Approved	12/24/2019 12:00:00 AM	ADDRESS	34.05705	-118.34935	Suppl Permit under original application. this scope fire sprinkle monitoring onlyOriginal Scope:  NEW FIRE ALARM SYSTEM WITH 26 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53113	14041-10000-04976	2840 W FRANCIS AVE	90005	1	132B197   645	5077025008	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Public Safety Only			02/24/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.05662	-118.28778	NEW FIRE ALARM SYSTEM FOR A 5 STORY APPARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53114	17041-20000-21541	4641 W COLORADO BLVD	90039	13	162B205    99		PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.14099	-118.2739	Plan check for energy only. TI to veterinarian clinic. New lighting. 1,166sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53115	17041-10000-40309	835 E 3RD ST	90013	14	129A215   259	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.04604	-118.23525	ALTERATIONS IN A GALLERY-NEW LUMINAIRES/CIRCUITS IN ART GALLERY/PANTRY/RECEPTION/RESTROOMS/CORRIDORPLAN CHEDK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53116	17041-10001-22182	1035 N SWARTHMORE AVE 1-105	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER DELTA  ONE AND TWO. SCOPE OF DELTA 1 INCLUDES -  SPATIAL RECONFIG IN BASEMENT FLOOR AND POWER RELOCATION IN SPACE SOME CIRCUITRY ADDITION ( SOME KITCHEN EQUIP. TO BE CHANGES).SCOPE OF DELTA 2 INCLUDES - CHANGES TO LIGHTING AND REVISIONS TO T-24 FORMS. SOME REVISIONS TO CIRCUITS AND LCP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53117	19041-10001-32025	110 E 9TH ST 7TH FLR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLAN CHECK ONLY. CHANGES TO APPROVED SET TO REMOVE ALL TRACK LIGHTING.. T-24 FORMS ARE UPDATED ACCORDINGLY. ALL CHANGES ARE CLOUDED UNDER DELTA 1. ((((Energy plan check for a partial office T.I located on the 7th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 26,231-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53118	19041-10000-32089	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.06664	-118.46903	Replacing the existing Fire Alarm system with 36 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53119	13041-10000-20552	7021 W HOLLYWOOD BLVD	90028	13	147B181   115	5548003020	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.1017	-118.34273	"pc for power and energy. CHANGE OF USE FROM RESTAURANT TO RETAILS OF 100' X 120' TENANT SPACE FOR ""MUJI USA""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53120	11041-10000-02289	1900 N MARIANNA AVE	90032	14	135A233    64	5223002006	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	Apartment			02/04/2011 12:00:00 AM			No Progress	06/17/2011 12:00:00 AM	ADDRESS	34.06363	-118.1789	EXISTING SERVICE AND DP, UPGRADE THE RESIDENTIAL UNIT, MATCH EXISTING AIC FROM THE DP FOR PANEL C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53121	13041-10000-12504	707 W WILSHIRE BLVD 52, 53, 54	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.04893	-118.2572	PLAN CHECK FOR TITLE 24 OF 6,400 SQ FEET. TENANT IMPROVEMENT FOR THREE RESTROOMS ON 52, 53, AND 54TH FLOOR. PLAN CHECK ONLY, PERMIT PULLED UNDER APPLICATION NUMBER 13041-10000-12504.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53122	13041-10000-23191	23708 W STAGG ST	91304	12	189B089   458	2027032006	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.21057	-118.64488	PV1 8.82KWdc 240V XFMR(-) INV. 2STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 36) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53123	19041-10000-07585	3526 S BURNSIDE AVE	90016	10	120B177  1037	5047012006	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.02256	-118.36254	PLAN CHECK FOR NEW PV SYSTEM USING CENTRAL INVERTER AND AC BATTERY BACK UP. (10) MODULES, (1) 3W INVERTER AND (1) 5KW AC TESLA POWERWALL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53124	14041-10000-24955	1333 W 42ND ST	90037	9	114B197   713	5020004018	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.00743	-118.29924	PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: POWER-ONE AURORA PV1-4.2-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53125	17041-10000-38197	11830 W SATICOY ST	91605	2	186B169   263	2317009013	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.20832	-118.39085	REPLACE OUTDOOR  HID LUMINAIRES WITH LED TYPEPLAN CHECK S FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53126	16041-10001-40450	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM			Corrections Issued	04/19/2017 12:00:00 AM	ADDRESS	33.97902	-118.43558	Replacing (28) light fixtures.(THIS PLAN CHECK WAS NOT FINALIZED BECAUSE ANOTHER SET OF APPROVED PLANS UNDER 16041-10000-02353 ALREADY EXISTED FOR  THE SAME PROJECT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53127	14041-10001-12531	1335 S SIERRA BONITA AVE	90019	10	129B177   510	5085028026	R1-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM			PC Approved	08/21/2014 12:00:00 AM	ADDRESS	34.05094	-118.35876	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTERS WITH OPTIMIZERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53128	19041-20000-53254	515 S FIGUEROA ST 12TH FLR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLAN CHECK FOR ENERGY TO (E) RESTROOMS ON 12TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53129	12041-10000-17222	913 S BROADWAY	90015	14	127-5A209 232	5139003003	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/24/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Closed	01/30/2014 12:00:00 AM	ADDRESS	34.04211	-118.25652	TEMPORARY 600A CONSTRUCTION SERVICE ONLY;SEALS PROVIDED IN THE CONDUITSOTHER PERMIT WILL BE FOR THE CONSTRUCTION EQUIPMENT; CONDUITS STUB UP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53130	19041-20000-01562	17455 W ROSCOE BLVD	91325	12	192B129   288	2787017012	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Apartment			01/14/2019 12:00:00 AM	05/27/2020 12:00:00 AM		Permit Finaled	07/15/2022 12:00:00 AM	ADDRESS	34.22121	-118.51393	1600A 208Y/120V 3ph-4w service, distribution, power and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53131	18041-20001-16002	4754 N AMIGO PL	91356	3	168B125   161	2176017003	RA-1	South Valley	Encino - Tarzana	Tarzana	Yes	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM			PC Approved	07/10/2018 12:00:00 AM	ADDRESS	34.15926	-118.53788	07-10-2018 Changes to an approved set of plans. Changes include upsize load center to 225A and increase main breaker to 175A. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53132	12041-10001-29913	12760 W MILLENNIUM BLDG A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			01/22/2014 12:00:00 AM			PC Info Complete	01/22/2014 12:00:00 AM	ADDRESS	33.97549	-118.41705	REVISION TO APPROVED PLANS. DELTA 10 - ADD NEW CENTRAL WATER HEATING, CIRCULATING PUMP FOR BUILDING AND REMOVE GAS WATER HEATER FOR DWELLING UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53133	13041-20000-28854	6200 N LEDERER AVE	91367	3	177B093   319	2035012020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.18306	-118.63905	New rooftop mounted PV system for an existing single family residence.  System is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53134	19041-10001-14224	945 W 8TH ST	90017	14	129A207    16	5144009079	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.04892	-118.26244	PLAN CHECK ONLY. CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE REVISION OF THE SINGLE LINE DIAGRAM AND CHANGE OF EQUIPMENT. NOTE CHANGES UNDER DELTA 2 & 3. ______________________________Plan check for temporary power for construction of new design build mixed use building. Highrise	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53135	15041-10001-01528	742 N HUDSON AVE 3-4	90038	4	141B185  1197	5533035***	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	34.08467	-118.33194	Expedited per applicant request.Install roof mounted solar array, interconnect with main panel. system size 1.53kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53136	19041-20000-25942	19846 W HAYNES ST	91367	3	180B113   526	2134026021	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.18959	-118.56585	Plan check for a PV1 roof-mounted PV system. System size is 5.28 kWdc/5.04 kWac and consists of (16) modules, (16) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53137	19041-20000-00574	15309 W CABRITO ROAD	91402	6	189B145   332	2654037024	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Apartment			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	12/22/2020 12:00:00 AM	PIN	34.21597403	-118.46661685	new fire alarm system 127 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53138	17041-10000-45016	915 N SYCAMORE AVE	90038	4	144B181   746	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.08769	-118.34291	PC FOR WAREHOUSE TI FOR T-24 ENERGY ONLY.SCOPE INCLUDES NEW PANEL CIRCUITS EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 27704 SQ.FT. VOLUNTARY STRUCTURAL RETROFIT OF (E) 1-STORY WAREHOUSE W/ MEZZANINE. (N) ENTRANCE AND WINDOWS ON EAST FACADE.B# 17016-10000-33233	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53139	17041-20000-44373	5670 W WILSHIRE BLVD Suite 450	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for Title 24 only. Project site is a suite on the 4th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,526 sq. ft.Note: Building application has been generated under 17016-10000-32453	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53140	19041-10000-53803	1259 S WEST BLVD	90019	10	129B185   714	5083031001	R2-1-O, R3-1	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Issued	12/31/2019 12:00:00 AM	ADDRESS	34.04987	-118.33342	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53141	17041-20001-22793	6551 N VAN NUYS BLVD Ste 201	91401	6	180B149   514	2236011023	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.1898	-118.449	8.3.2017 - Plan check for modifications to approved set. Update plans to show existing lighting in operatories, steri, and office areas. Update T24 compliance forms to include existing lighting in calculations.======Tenant improvement of (E) dentist's office.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53142	13041-10000-32546	10167 W MOTOR PL	90064	5	126B165   606	4308010011	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	12/31/2013 12:00:00 AM	ADDRESS	34.04119	-118.40272	PV1, ROOF-MOUNTED SOLAR ARRAY. (E)200A MAIN. DESIGN IS DONE ON MICROINVERTER STANDARD PLAN. SYSTEM IS 9.5kW AC. LOAD CENTER IS USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53143	15041-10002-35736	1622 N WILCOX AVE	90028	13	148-5A187 245	5546007006	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.10042	-118.33085	PC FOR CHANGES TO APPROVED SET OF PLANS. UPDATE SHORT CIRCUIT RATING OF INVERTER UNIT. CHANGE CLOUDED IN RED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53144	10041-20003-17057	825 E 4TH ST 1-53	90013		127-5A215 174	5163011028	M3-1		Central City North	Historic Cultural			Electrical	Electrical	Apartment			06/19/2012 12:00:00 AM			PC Approved	06/30/2012 12:00:00 AM	ADDRESS	34.0435	-118.23728	Resubmit for As-Built.   All changes indicate by DELTA-A3 as shown on plans.  Add pool panel, water heaters, and replace lighting fixtures.Note: Permit issued under a separate application.*****Change from commercial to adoptive reused in Methane Zone area.  New service, panels, and branch circuits.  Plan check for energy and power.  Variance for separate fire alarm system submitted. *****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53145	15041-10000-36118	9425 N CANOGA AVE	91311	12	198B105    45	2746014015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	04/15/2016 12:00:00 AM		Issued	04/15/2016 12:00:00 AM	ADDRESS	34.24205	-118.59773	$0 permit fee is due to State Senate Bill SB-1222. PV2, ROOF MOUNTED SYSTEM UNDER LADWP FIT (FEED IN TARIFF) PROGRAM - TOTAL SIZE 705.87 KW-DC, 624KW-AC. (2139) MODULES, (26) INVERTERS AND (3) LOAD CENTERS. (2139) SUNIVA OPT 330-72-4-100(26) SMA AMERICA STP-24000TL-US-10	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53146	15041-20000-25845	5700 W ADAMS BLVD	90016	10	123B173   950	5048030033	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Expired	09/04/2017 12:00:00 AM	ADDRESS	34.03226	-118.3671	PC FOR 600A SERVICE UPGRADE. RECONNECT ALL EXISTING EQUIPMENT. PC FOR NEW SERVICE AND SHORT CIRCUIT RATINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53147	13041-20000-00573	5437 N DAHLIA DR PV-1	90041	14	165A227    78	5669009001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.14621	-118.19859	PV-1. Albers Residence. 2.6kW. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53148	13041-10000-11453	8426-8428 W 3RD ST	90048	5	138B173   812	5511032041	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	08/12/2013 12:00:00 AM	ADDRESS	34.07289	-118.3741	CHANGE OF USE FROM RETAIL AND BEAUTY SALON TO COMBINED USE OF SMALL RESTAURANT (998 SQ FT) AND RETAIL (560 SQ FT), PLAN CHECK DOES NOT INCLUDE RETAIL SPACE IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53149	14041-10001-17165	16625 W BOSQUE DR	91436	5	165B137   308	2291006020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM			PC Approved	07/15/2014 12:00:00 AM	ADDRESS	34.14776	-118.49516	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 10.455 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS.(41) MODULES: TRINA SOLAR TSM-250PA05.18(2) SOLAREDGE SE6000A-US-ZB-U AND SE3000-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53150	15041-10001-43025	964 S BERENDO ST PHASE 1	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.05378	-118.29358	2/19/16:  Change to approved set: Removed some loads and added 3 branch circuits for control panel. Removed classroom area from the scope of work.12/21/15FULL PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY BAPTIST CHURCH AND PRIVATE SCHOOL OVER ONE LEVEL OF SUBTER. PARKING GARAGE. NEW UNDERGRND SERVICE 2500A,480/277, 3-PHASE. TOTAL AREA (UNCONDITION + CONDITIONED) FOR ENERGY IS 229958 SQ FT. NONE METHANE ZONE ON ZIMAS*PROJECT WILL BE SPLIT INTO TWO PHASES. PHASE 1 OF 2. CHANGES INCLUDES THE PARKING STRUCTURE AND 1ST FLOOR OF THE CHURCH AND SCHOOL. *Note 1/25/16: The building under this project covers addresses as follow (APN to all is 5078008034):964 S. Berendo St., 979 S. New Hampsire Ave., 979 1/2 S. New Hampsire Ave., 981 S. New Hampsire Ave.***PER APPLICANTS REQUEST NO CHANGES DONE FROM ORIGINAL TO NEW APPLICATION. BLDG PERMIT UNDER 12010-10002-02799)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53151	17041-10000-20019	7864 N GAZETTE AVE	91306	3	189B109   645	2108028009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.21362	-118.58732	Installation of new roof mounted solar PV system on existing single family dwelling.  Central inverter system with AC coupled battery back up.  Total system size = 5 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53152	17041-30000-39368	15200 W MAGNOLIA BLVD	91403	4	171A147    14	2263002014	[Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.16459	-118.46421	Plan check for new fire alarm system for 10 units appartment. Total fire alarm devices: 64 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53153	17041-10000-15998	15031 W RINALDI ST	91345	7	213B145    64	2664022028	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.27918	-118.46029	PLAN CHECK FOR POWER AND ENERGY FOR TI (NEW ADMIN OFFICE). SCOPE INCLUDES ADDITION OF LOAD TO EXISTING DISTRIBUTION EQUIPMENT(30 DAY METER READING ARE PROVIDED ON SINGLE LINE DIAGRAM). TOTAL CONNECTED LOAD >400A. TOTAL SQ FT. 7316.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53154	18041-10000-17329	7830 N FARMDALE AVE	91605	6	189B169   588	2311010017	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.21297	-118.38052	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 3.8KVA(AC) & 4.72KVA(DC) CONSISTING OF 1 CENTRAL INVERTER (SOLAR EDGE SE3800H-US) WITH 16 MODULES AND P320 POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53155	13041-20000-07234	5700 W WILSHIRE BLVD #100	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	34.06218	-118.35303	Installation of New outdoor canopy lighting to an existing commercial building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.  ((Permit fees are under INSPECTION))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53156	17041-10000-45558	207 N LAKE SHORE TER	90026	13	135A207   195	5159017009	R3-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.06462	-118.26119	PC for 3.8 kW roofmounted solar PV.  Installing 11 modules and optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53157	12041-20000-08700	8456 N SAN FERNANDO ROAD	91352	6	192B173   259	2632027030	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.22364	-118.37468	Tenant improvement. 1250 conditioned sqft. Single story commercial. Office space. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53158	17041-10000-12661	2045 E WASHINGTON BLVD	90021	14	118-5A215   5	5167019046	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.01926	-118.23579	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 355,500 SQFT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53159	15041-20000-12035	16829 W DEVONSHIRE ST	91344	12	204B133   189	2684007014	CR-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.25766	-118.49903	TI to existing commercial building (dental office). Change of use from retail. Plan check for power and energy. Adding new lighting including emergency. Total sqft. 2,568	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53160	16041-20000-40388	6028 N CALVIN AVE	91356	3	177B117   619	2153035022	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.17989	-118.55544	Plan check for a PV1 roof-mounted PV system. System size is 15.4 kWac and consists of (55) modules, (55) micro-inverters, and (1) load center.$0 permit fee is due to Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53161	18041-10000-02708	219 1/2 W 90TH ST	90003	8	094-5A203  27	6040029006	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	04/03/2018 12:00:00 AM	ADDRESS	33.95471	-118.27661	PC FOR ROOF MOUNTED PV ON SFD at 219 1/2 90th St.SCOPE INCLUDES 18 MODULDES WITH OPTIMIZERS AND CENTRAL INVERTER. SYSTEM SIZE 5.76 KWDC (OPTIMIZERS) 3.8 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53162	11041-20000-02257	9221 N CORBIN AVE	91324	12	198B117   166	2761001073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	ADDRESS	34.23786	-118.56248	energy plan check lobby	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53163	17041-20001-38468	6129 N ST CLAIR AVE	91606	2	177B165   419	2333006017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.18205	-118.39994	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted solar array on SFD.Total system size: 11.52kW ungrounded.(36) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53164	16041-10001-24333	515 N HOMEWOOD ROAD	90049	11	135B137   250	4426036003	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.06761	-118.48758	Expedited feesPV1 roof mounted solar system installation to a single family home. Installing 45 Microinverters rated at 250 Watts each (M250-60-2LL). Total system size is equivalent to 11.25 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53165	11041-10000-24599	3992 S INGLEWOOD BLVD	90066	11	111B157   319	4214021045	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Apartment			11/16/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.00232	-118.42561	new fire alarm for a three story apartment bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53166	14041-10001-13367	1677 S ROOSEVELT AVE	90006	10	126B193   401	5074025009	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.04286	-118.30196	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53167	13041-10001-29717	1108 N TAMARIND AVE	90038	13	144B189   645	5534010011	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			PC Approved	12/10/2013 12:00:00 AM	ADDRESS	34.09102	-118.3189	][][changes made to an approved set of plans; changes is to account for lighting additions ][][TENANT IMPROVEMENT TO (E) ART STUDIO; TITLE 24 PART 6 ENERGY, LIGHTING FOR A 2-STORY STUDIO COMMERCIAL BUILDING. SCOPE OF WORK IS LESS THAN 400A .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53168	12041-10000-03886	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	04/16/2012 12:00:00 AM		Permit Finaled	06/05/2012 12:00:00 AM	ADDRESS	34.30237	-118.46212	Ti in a cafeteria. New lighting, panel, and CKTs. EPC is for power and Energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53169	13041-10001-34442	2607 E DARWIN AVE	90031	1	136-5A221 262	5210003037	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.06767	-118.21518	Expedited RSES plan check per applicant request.{{PV1, Install a 2.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (9) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. Ungrounded system.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53170	15041-20001-07043	7748 N GRAYSTONE DR	91304	12	189B089   287	2017027009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.21242	-118.65403	EXPEDITE FEESPV1 SFD TOTAL SYSTEM SIZE 12.2KW AC USING TOTAL OF 3 INVERTERS AND 64 SOLAR MODULES. TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. ROOF MOUNTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53171	19041-10000-45586	8373 S WESTLAWN AVE	90045	11	096B161   479	4112028008	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	33.96104	-118.40638	INSTALLATION OF ONE NEW TESLA POWERWALL2 BATTERY TO AN EXISTING 3.8KWAC PV1 SYSTEM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53172	13041-10000-32074	1945 W 26TH ST	90732	15	012B189   522	7563007016	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	33.72525	-118.32016	PV1.  Install 9.00 kW DC roof-mounted PV system, interconnect with main service panel.  36 modules: LDK 250W.  2 inverters (transformered and transformerless): SolarEdge SE5000A-US and Sunny Boy 5000-US.  Permit already issued under 13041-10000-27008 and covers most of the proposed equipment except for the additional inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53173	13041-10000-28136	255 S GRAND AVE	90012	14	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Expired	04/26/2016 12:00:00 AM	ADDRESS	34.05332	-118.25122	permit to be pulled at EPC counter only. PC FOR ENERGY. TI TO (E) MIXED USE FOR COMMON AREA OF RESIDENTIAL HIGH rise (lobby/driveway, second floor, and terrace).Subject to full plan check as determined by inspector.CRA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53174	19041-10000-50541	1721 N NORTH BROADWAY	90031	1	138A219    88	5447020006	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.07205	-118.22323	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS ONE NEW FIRE ALARM PANEL, ONE NEW COMMUNICATOR, AND 72 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53175	14041-20000-25757	1840 S CENTURY PARK EAST 5TH FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.06188	-118.41473	TENANT IMPROVEMENT ON SUITE 500 (10,487 SF) NEW LIGHTING. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53176	15041-20000-26411	8631 W 3RD ST East Tower	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to the corridors and lobbies for floors 1 through 11. Total lighting area = 18,049 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53177	18041-20001-45133	20447 W NORDHOFF ST	91311	12	195B109    60	2781001037	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.232	-118.57917	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, CHANGE FROM UNDERHEAD TO OVERHEAD FEEDS FOR DISTRIBUTION BOARDS, REMOVED A SECTION FROM THE ELEVATIONS, AND MINOR CHANGE TO SITE PLAN. CLOUDED DELTA A CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53178	18041-20000-04014	3667 S MENTONE AVE	90034	5	120B161  1081	4314009015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			02/02/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.02268	-118.40734	Full plan check for  a new 3-story, 10-unit apartment building with a basement parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53179	15041-20001-30225	2117 N PRINCETON AVE	90026	13	144A211   129	5420035013	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.08963	-118.24918	Change to approved set of plans. Changes include add 2 modules of  Solar World SW315 XL MONO to existing modules{{{{{{{{{PV1 system,Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3kWac. Ungrounded system. Using (1) 400W power optimizer per pv module.(6) 320W pv modules.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53180	17041-20001-28151	310 S MARIPOSA AVE 1-43	90020	10	135B197   238	5502003016	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.06862	-118.29902	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on apartment building.20kW ungrounded system (10+10).(66) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53181	19041-20000-07753	9570 W HIDDEN VALLEY ROAD pv1	90210	4	156B165   249	4387007006	RE20-1	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.12046	-118.40493	pv1install roof mounted pv system sized 20.2KW AC interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53182	16041-20000-45070	5670 W WILSHIRE BLVD Ste 1650	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI to (E) commercial office space in highrise building.  16016-10000-30004.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53183	14041-10000-26928	4503 W PICO BLVD	90019	10	129B185   964	5083031006	C4-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.04868	-118.3339	TI fort existing commercial space.  Total area = 832 sq. ft. permit previously pulled under 14041-10000-24629.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53184	13041-10002-03643	16500 W VENTURA BLVD	91436	5	168B137   382	2284005036	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.15743	-118.49262	Changes to approved set going with two transformers ( existing 30 KVA) and new 45 KVA --Change of use, new Dental office.  Full plan check.  Existing 4-story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53185	17041-10000-08972	535 N MAIN ST	90012	14	132A215    59	5408007007	[T][Q]PF-2D	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	PIN	34.05695881	-118.23964661	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 20850 SQ FT. INDOOR + OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53186	15041-20000-24417	12500 W BRANFORD ST	91352	6	201B165   107	2629001006	(Q)M2-EZ1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Expired	10/25/2017 12:00:00 AM	ADDRESS	34.24638	-118.40551	Plan check for power and energy.  Install task lighting in existing space, part of the space is being alter(lighting). Total indoor enclosed area: 292,189 sqft. Total motor on MCP133: 13, Total motor on  MCP 192: (3) 3HP, Total motor on MCP 141: 7, Total motor on MCP 191: 11, Total motor on MCP 031: 1Note: orginally approved set of plan indoor lighting is included	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53187	13041-20000-28858	8700 W BEVERLY BLVD Rm G-107C-Rm 6032	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.07666	-118.3805	Plan check for power and energy. Scope of work in the oxygen tank storage area. Room G-107C and Room 6032. New panel AAP-2&3 not in scope, to be provided by others.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53188	18041-10000-23474	6211 S VERMONT AVE	90044	8	105B197   999	6003030013	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2371.01	Electrical	Electrical	Apartment			06/22/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	08/20/2023 12:00:00 AM	ADDRESS	33.9828	-118.29168	PC FOR POWER AND ENERGY FOR NEW 4 STORY 15 UNITS APARTMENT BUILDING. THIS PROJECT IS FOR AFFORDABLE HOUSING. SCOPE INCLUDES A NEW 800A 120/240 SERVICE/DISTRIBUTION BOARD, NEW CIRCUITS, NEW LIGHTS.  TOTAL AFFECED AREA 6773 SQ.FT. B# 17010-30000-01077	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53189	16041-10000-29775	8519 W PICO BLVD	90035	5	132B173  1243	4332028039	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	03/18/2017 12:00:00 AM	ADDRESS	34.05369	-118.37695	FULL PC FOR POWER AND ENERGY. CHANGE OF USE CORE & SHELL FROM RETAIL TO RESTAURANT. SCOPE INCLUDES ADDING A NEW 100A SUBPANEL, NEW RECEPTACLES, AND NEW LIGHTS FOR A NEW RESTUARANT. TOTAL AFFECTED AREA IS 2235 SQ. FT. B#16016-10000-19748	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53190	15041-10000-19355	8500 W BEVERLY BLVD Space 847	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a retail (VANS) T.I. with Tailored method. Scope of work includes new lighting and receptacles. Total area is 3536-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53191	17041-10000-22483	1431 W E ST	90744	15	030B201   666	7412021035	[Q]M3-1VL-O-CUGU	Harbor	Wilmington - Harbor City			9800.15	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Issued	08/29/2017 12:00:00 AM	ADDRESS	33.77476	-118.28036	PC FOR SERVICE UPGRADE. REPLACE SERVICE WITH NEW 2000A AND REFEED ALL EXISITING LOADS. UPGRADING 1200A TO COMPLY WITH NEW AIC RATING. PC FOR POWER SYSTEM ONLY. NOTE THAT CLOUDED DISTRIBUTION BOARD MCC79 IS UNDER A SEPERATE PERMIT AND SHALL NOT BE ENERGIZED UNITL MCC79 PERMIT IS FINALED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53192	18041-10000-12405	13680 W SAYRE ST	91342	7	225B157   588	2509016004	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.31229	-118.4311	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURE AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53193	19041-10000-51875	5856 S WEST BLVD	90043	8	108B185  1090	4004006001	C2-1VL-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	33.98773	-118.335	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53194	16041-20000-36990	18711 W SHERMAN WAY	91335	3	183B121   100	2118026019	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.20128	-118.54074	office energy and power plan check retail for future just temp lighting in multiuse building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53195	17041-10000-22380	6960 S CENTINELA AVE	90230	11	105B165   480	4220014057	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	33.9837	-118.39937	New Fire alarm system on an (E) 3 story commercial building, (2) FA panel, (48) FA devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53196	12041-10000-06016	8732 S READING AVE 1-11	90045	11	096B169   627	4125016012	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	33.95901	-118.3814	Plan check for fire alarm system for an new 11 unit apartment building.  1 panel and 86 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53197	15041-20000-39771	5800 W SUNSET BLVD PHASE 1A	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENTS FOR TV STUDIOS AND ASSOCIATED SUPPORT SPACES..  PHASE 2 of 5 PHASE PROJECT FOR STAGE 6 AND BUILDINGS 16. STAGE 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53198	16041-10000-36149	13215 W BOMBAY ST	91342	7	225B157   436	2512020060	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.31397	-118.42066	PV1. NEW SOLAR SYSTME ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(9)MODULES-JINKO EAGLE 265W(9)OPTIMIZERS-P300(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53199	17041-10000-45515	4826 N BILOXI AVE	91601	4	168B177   412	2420006017	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.15853	-118.35812	PC for rooftop solar for new 20kW(AC)/ 23.1kW(DC) system. Installing 70 PV modules with optimizers, two inverters and 100A solar load.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53200	13041-10000-26071	2222 S BEVERLY DR	90034	5	126B165   381	4309017006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.04277	-118.39516	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 5.25KW DC IN A 2-STORY HOME. NON-STANDARD PLAN , WITH 2 STRINGS.(21) MODULES: TRINA SOLAR #TSM-250PA05.18(1)INVERTER: POWER-ONE #AURORA PVI-4.2-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53201	19041-10000-44895	17242 W GOYA ST	91344	12	222B133   505	2602015017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.30285	-118.50798	[EPLAN] PLAN CHECK FOR NEW ESS(TESLA POWERWALL) TO EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53202	16041-30002-26769	345 S NEW HAMPSHIRE AVE 1-66	90020	10	135B197   394	5502007009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.21	Electrical	Electrical	Apartment			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.06775	-118.29309	02/09/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Inverter manufacturer has changed and the power rating of (1) inverter has been reduced to 8.2 kWac, for a total system size of 38.2 kWac. *****Previous Work Description*****Plan check for PV roof mounted system. System size: 40kW with 176 modules and 4 inverters(10.0kW) connected to MSP.Note: $0.00 permit fees due to Senate Bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53203	13041-10001-29577	9110 N CREBS AVE	91324	12	198B121   771	2763021052	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.23597	-118.54401	Expedited RSES plan check per applicant request. ((((PV1.  Install 9.75 kW DC roof-mounted solar array, interconnect with main service panel.   Inverter: Fronius IG Plus V 7.5.  39 modules: Trina Solar TSM-250PA05.18.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53204	17041-20000-14794	10440 W MAGNOLIA BLVD	91601	4	171B177   659	2419021002	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.16476	-118.35852	new fire alarm system 49 devices and 1 facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53205	15041-20000-27124	12500 W RAJAH ST	91342	7	231B165    11	2582038038	RE11-1-H	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Info Complete	09/18/2015 12:00:00 AM	ADDRESS	34.32666	-118.40585	Plan check for PV GROUND MOUNTED system. System size: 5 kW with 20 modules and 20 microinverters.     Building plan check #15020-20000-02533	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53206	19041-20000-03997	11222 W CHALON ROAD	90049	5	141B145   191	4369010004	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.083	-118.4613	Plan check for PV roof mounted system, system size;:19.8KW DC, 18.211 AC with 60 AC Modules  connected to existing 400A service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53207	18041-30000-41585	1800 S CENTURY PARK EAST 700	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.06244	-118.41523	PLAN CHECK FOR T24 ONLY TO 8,159 SQFT. INTERIOR OFFICE T.I. NEW LOADS ARE FED FROM EXISTING PANELBOARDS.  (B# 18016-10000-30804)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53208	16041-10000-19681	1875 CENTURY PARK EAST #1100	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			PC Info Complete	06/06/2016 12:00:00 AM	PIN	34.06139196	-118.41527843	"TI on an (E) commercial build. chnag eof use from hair salon to a restaurant ""Let's Roll Sushi"". New connected load < 400A. PC for T-24 only. Total area: 900 sq.ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53209	17041-10001-32807	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM			PC Approved	02/06/2018 12:00:00 AM	ADDRESS	33.94221	-118.40701	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include revising power/lighing floor plan layout. No changes to Title 24 calculations. Changes to reflect as built.Note: Permit is paid under PCIS#17041-10000-32807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53210	14041-10001-04667	4652 N WORTSER AVE	91423	4	168B161   660	2362003002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.15553	-118.4169	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(19) MODULES:  CNADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53211	19041-10000-37797	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Issued	12/03/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	ENERGY PC ONLY FOR TWO NEW RESTROOMS IN COMMON AREA OF GROUND FLOOR PARKING GARAGE. AREA OF SCOPE 317SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53212	15041-20000-08690	17383 W SUNSET BLVD Suite A342	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.03917	-118.55529	Title 24 plan check only.  Total area = 926 sq. ft.T.I. to existing office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53213	14041-10000-09253	1902 E MARENGO ST 103-104	90033	14	132A223    33	5201016003	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.05756	-118.21009	CHANGE OF USE AND TENANT IMPROVEMENT FROM RETAIL TO RESTAURANT. FIRST TENANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53214	14041-20001-31388	20832 W VALERIO ST	91306	3	186B109  1048	2113013***	(Q)RD2-1, (Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.20456	-118.58754	EXPEDITE PER APPLICANT REQUEST[PV2Install a roof-mounted solar array on a Condominium. Interconnect with 200A MSP.System size: 6kW. Ungrounded system. Using 300W power optimizers.31 255W pv modules across 2 strings (13+18).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53215	19041-10000-00866	11329 W OXNARD ST 1-10	91606	2	177B173  1097	2337009004	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Apartment			01/08/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	12/10/2021 12:00:00 AM	ADDRESS	34.17956	-118.37797	Full plan check for three-Story Ten-Unit Apartment Building with attached Garage. Scope of work includes new 800 amp service 120/240 single phase, circuits equipments and lighting total effected area 4000 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53216	19041-10000-32231	12565 W STRATHERN ST	91605	2	189B161   358	2308010002	[T][Q]MR1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			Reviewed by Supervisor	08/27/2019 12:00:00 AM	ADDRESS	34.21585	-118.40784	PV2, New rooftop mounted system, system size is 48.9 KWdc/39.2KWac. Scope of work is 127 modules (Qcell 385) with optimzers (SE P505), four inverters (3 SE11400H-US, and 1 SE5000H-US), leading to a combiner panel, terminating in a line side tap. No panel uprgrade, and service is existing.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53217	10041-10000-23525	3650 W MARTIN LUTHER KING, JR BLVD Unit # 187	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	05/12/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	<<<<<<<<<<PER INSPECTOR'S REQUEST, MISC PERMIT FOR UNIT # 191 ISSUED UNDER 10041-10001-23525 AND UNIT # 195 ==> 10041-10002-23525 . >>>>>>>>>TENANT IMPROVEMENT-SUBDIVIDING COMMERCIAL SPACE INTO 3 EA TENANT SPACES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53218	15041-20000-03475	9200 N OAKDALE AVE 9TH FLOOR	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.23811	-118.56674	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 9TH FLOOR. 16875 SQFT, EMERGENCY LIGHTING. NEWLY CONNECTED LOAD < 400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53219	16041-10000-19487	8900 N DE SOTO AVE # 101	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Issued	06/03/2016 12:00:00 AM	ADDRESS	34.23162	-118.58832	PC for energy only to a pre-fabricated metal bulding (manufacturing building) Adding new lighting and power. Adding new equipment, newly connected load is less than 400 amps. Total sqft= 1013	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53220	14041-20000-25392	23355 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Closed	04/29/2015 12:00:00 AM	ADDRESS	34.1579	-118.63422	Replacement of 800A service equipment and unit panel in disrepair with new 1200A service equipment - ER1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53221	19041-10000-50046	350 S GRAND AVE 25TH FLOOR	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.05173	-118.2522	Energy plan check only. Area of scope for an existing space 1975SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53222	13041-10000-30010	3045 S CRENSHAW BLVD	90016	10	120B185   700	5050031040	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	ADDRESS	34.02629	-118.33529	PLAN CHECK FOR FIRE ALARM SYSTEM. 2 STORY BUILDING. CHURCH.  1 FIRE ALARM PANEL AND 289 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53223	12041-10000-18326	920 W DOWNEY WAY	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.02063	-118.28879	Plan check for replacing substation Electric Vault A  (EVA)  to supply Biegler Hall (BHE). New medium voltage switchgear, panels and circuits. New panel and ATS to seperate life safety and optional load in a methane zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53224	17041-20000-43921	6634 W 87TH PL	90045	11	096B165   864	4122019006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Expired	03/20/2024 12:00:00 AM	ADDRESS	33.95777	-118.40571	Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.3kW ungrounded pv system. (9) 300W pv modules. (1) Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53225	10041-10000-16405	452 S MAIN ST	90013	9	129A211   150	5148009011	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.04697	-118.24801	Installation of new fire alarm system for a 6 stories apartment bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53226	18041-10000-31791	10250 W SANTA MONICA BLVD 2740	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR POWER AND ENERGY, CORE AND SHELL TENANT IN SUITE # 2740 OF CENTURY CITY WESTFIELD MALL.2,175 SQR FT. BLDG PERMIT: 18016-10000-26063.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53227	19041-10000-17296	333 S GRAND AVE #1000	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	Energy plan check for an office T.I located on the 10th floor of a high rise building. Scope includes new lighting and equipment with a total area of 1889-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53228	14041-10000-08937	1447 S SIERRA BONITA AVE	90019	10	129B177  1050	5069019036	R2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.0481	-118.35953	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53229	19041-10000-43089	3101 W EXPOSITION BLVD	90018	10	120B185  1292	5044003016	CM-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	05/28/2020 12:00:00 AM		Permit Finaled	03/29/2021 12:00:00 AM	ADDRESS	34.02175	-118.32982	FULL PC FOR POWER AND ENERGY.  EXISTING 3000A SERVICE, 480/277V.  ADDING NEW PANELS, XFORMERS, INVERTER, AND ELECTRICAL EQUIPMENT. TITLE 24 ENERGY TOTAL AFFECTED AREA IS 44942 SQ/FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53230	18041-10000-07986	1500 N EL CENTRO AVE 6TH FL	90028	13	147A189   234		(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.09917	-118.32359	PC for power and energy for first time tenant for office space. Installing two new panels, lights, receptacles and lights. Total area is 13864sqft. B#18016-10000-06785	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53231	13041-10000-11782	19917 W CANTARA ST	91306	3	192B113   656	2106001030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.21895	-118.56727	PV1 ROOF MOUNTED SOLAR INSTALLATION, TRANSFORMERLESS ON NON STANDARD PLAN. SYSTEM SIZE IS 4.9KW USING TWO STRINGS AND 20 MODULES. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: POWER-ONE # AURORA PVI-5000-OUTD-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53232	14041-10000-22930	3657 N MEADVILLE DR	91403	4	159B145    81	2279018009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.13598	-118.46847	PV1, INSTALL 7.905 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(31) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53233	12041-10000-24934	8931 W ELLIS AVE 3RD FLOOR	90034	10	123B169  1440	4312011006	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.02949	-118.38998	Change to lighting for an existing 3-story office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY FOR ENERGY.  No change to the emergency lighting per the applicant and is NOT part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53234	15041-10000-05812	700 S FLOWER ST SUITE 650	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	T24 FOR EXISTING HIGH RISE OFFICE BUILDING ON 6TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53235	10041-20000-14468	1801 W BEVERLY BLVD	90026	13	135A207    77	5159007004	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2084.00	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	PIN	34.06551064	-118.26702214	lighting in office area. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53236	10041-10000-11280	21300 W ERWIN ST	91367	3	177B105    36	2149005042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.18266	-118.59548	TENANT  IMPROVEMENT  AND CHANGE OF USE FROM MFG/OFFICES TO MEDICAL OFFICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53237	17041-10000-27978	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	PC FOR POWER  FOR BATTERIES REPLACMENT FROM LEAD BATTERY TO LITHIUM BATTERY RACKS FOR UPS SYSTEM  (DC SIDE).SCOPE INCLUDES 6 RACKS OVER 600 A  EACH.CALL APPLICANT MR. KHAZRA  AT  (310) 753-8923 FOR QUESTIONS AND CLARIFICATIONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53238	12041-10001-29023	10125 W VALLEY SPRING LANE	91602	4	165B181   478	2424035011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM			PC Approved	02/11/2013 12:00:00 AM	ADDRESS	34.14651	-118.35118	"(((((( Plans were approved for 1"" conduit size however the contractor is using a .75"" conduit. and mounting height changed 28"" . made changes on new standard plan)))))New roof mounted PV1 for a single family. (use enphase 215, MODULES SHALL BE ISTED BY THE CITY OF LA RECOGNIZE TESTING AGENCY)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53239	16041-10001-43185	4147 S SUNNYSIDE AVE	90066	11	108B153  1049	4230011017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2016 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	33.99028	-118.43885	EXPEDITE FEESPC FOR PV SYSTEM ROOF MOUNTED, TOTAL SYSTEM SIZE 13KW AC USING 2 CENTRAL INVERTERS AND TOTAL OF 49 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53240	18041-10001-08687	1005 S MATEO ST	90021	14	123A217   204	5166019004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM			PC Approved	06/27/2018 12:00:00 AM	ADDRESS	34.03128	-118.23244	SUPPLPEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - SCOPE INCLUDES RELOCATION OF PANEL M2 FROM OUTSIDE OF THE BUILDING TO INSIDE. CHANGES APPROVED UNDER DELTA #2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53241	12041-10000-20791	17366 W CHASE ST	91325	12	192B129   229	2787019004	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.22308	-118.51211	Plan check for 15.369KW roof mounted photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53242	16041-10000-34573	18716 W PRAIRIE ST	91324	12	198B121   495	2763015014	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.23901	-118.5411	PV1 installing new solar system for a single family dwelling. Installing 26 micro inverters rated at 345 watts each for a total system size of 8.97 kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53243	14041-10000-13742	1314 S SANTEE ST	90015	14	124-5A209 228	5133018007	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.03465	-118.25851	T24, REMOVE HID LIGHT FIXTURES AND REPLA CE WITH NEW FLUORESCENT FIXTURES. TOTAL AREEA 880 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53244	16041-20000-39615	4707 N TYRONE AVE	91423	4	168B153   509	2248002044	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.15616	-118.44448	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.7.68kW ungrounded system. (32) EnPhase M250 microinverters. (32) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53245	14041-10000-31686	4616 W DE LONGPRE AVE 5th Floor	90027	13	147B197   891	5542017033	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.0968	-118.29007	Remodel of an existing clinic on the 5th floor of an existing outpatient medical office building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53246	12041-10000-28953	20750 W VENTURA BLVD #150	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.16638	-118.58506	(#150)  TENANT IMPROVEMENT WORK ON 1,740 SF OF TOTAL OFFICE FLOOR AREA;  NEW LIGHTING AND RECEPTACLE. EPC IS FOR T24 AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53247	16041-20002-45779	20922 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.21974	-118.58937	10/16/2017changes to an approved set of plans.  changes to reflect field conditions, noted delta 1.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53248	14041-20000-10698	15350 W SHERMAN WAY #423	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.20099	-118.46808	new plan check for change in design. new license designer on record. T.I. to existing offices.  Install general/emergency lighting on the 4th floor.  Plan check for energy only.plan check only application. permit already issued.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53249	17041-20000-28659	1748 W CUMBRE DR	90732	15	012B189    24	7560028001	R1-1XL	Harbor	San Pedro	Coastal San Pedro, Northwest San Pedro	YES	2974.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	07/30/2020 12:00:00 AM	ADDRESS	33.72945	-118.31623	Plan check for power and energy. Project site is an existing commercial building. Project scope is a fire rebuild/tenant improvement. Work includes a 1,600 Amp service and a total lighting area = 30,314 sq. ft.Note: Building permit has been issued under 15016-40000-05472.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53250	14041-20000-25457	21301 W BURBANK BLVD 4TH FLR	91367	3	174B105    82	2149019014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.17351	-118.59524	TI FOR FULL 4TH FLOOR. NEW DISTRIBUTION EQUIPMENT AND POWER AND LIGHTING. PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53251	18041-20000-14996	1070 N SOMERA ROAD	90077	5	144B149   166	4369032017	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Expired	09/22/2023 12:00:00 AM	ADDRESS	34.09151	-118.45886	Installation of 27 kWh rated energy storage system and associated distribution for (E) SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53252	17041-30002-29371	10432 N SEPULVEDA BLVD	91345	7	207B145   734	2649019009	C2-1, P-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM			PC Info Complete	12/08/2017 12:00:00 AM	PIN	34.26038748	-118.46690796	Plan check for First Time tenant resturant power only per inspector request. Energy plan check was approve previously on 17041-30000-29371. Building application Number: 17016-20000-11298***********************Previouse Work Description***********************************Plan check for Title 24 only in Tenant improvement to (e) resturant. Total area: 1,825 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53253	18041-10000-10718	123 E WASHINGTON BLVD	90292	11	105A145   405	4227018029	C4-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	33.98014	-118.46527	PLAN CHECK FOR TITLE 24 ONLY - SCOPE INCLDUES REPLACEMENT AND ADDITION OF EXISTING LIGHTING WITHIN A  RESTAURANT - TOTAL AFFECTED AREA = 980 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53254	16041-20000-42292	9223 N DEERING AVE	91311	12	198B105   114	2746010048	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.23859	-118.59622	TRANSFORMER, PANEL AND CORD DROPS FOR CIRCUITS (NO LIGHTING) PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53255	16041-20001-11023	5727 W LA MIRADA AVE	90038	13	144B189   118	5536001017	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			07/27/2017 12:00:00 AM			PC Approved	07/27/2017 12:00:00 AM	ADDRESS	34.09387	-118.31452	Removal of corridor and stairwell occupancy sensor control - building qualifies as lowrise multifamily residential, control features not required.  Delta-2 revisions only. (((New 28 unit apartment building 3 story type V-A over 1 story of subterranean parking type I-A.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53256	16041-10000-38509	15242 W BLACKHAWK ST	91345	7	204B145   225	2649020003	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.25816	-118.46454	PC FOR PV ROOF MOUNTED SYSTEM WITH 8 MODULES. USING MICROINVERTER SYSTEM ENPHASE M250.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53257	18041-20000-33693	9617 N GIERSON AVE	91311	12	201B101   479	2727010006	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.2448	-118.61175	installation of battery back up system to an existing pv system. 5KWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53258	12041-20000-02398	11818 W DOROTHY ST 1-26	90049	11	129B145   285	4265017049	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			02/01/2012 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.05151	-118.4671	fire alarm system 26 units apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53259	19041-10000-20343	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM			PC Info Complete	06/11/2019 12:00:00 AM	ADDRESS	34.05885	-118.44283	PC for T24 for a TI for conversion from office to a bank. Total affected area is 8684 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53260	18041-20000-44743	8314 N GLORIA AVE PV1	91343	12	192B141   452	2673018038	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.22184	-118.48067	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53261	17041-10000-39684	2652 S LONG BEACH AVE EAST UNIT 3	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM			PC Approved	11/16/2017 12:00:00 AM	ADDRESS	34.01303	-118.24279	PC for T24 only for new lights in cooler rooms and office spaces. Installing one new panel, new lights, receptacles and cooler equipment. B# 17014-10000-04876.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53262	17041-20002-29159	19161 W ARMINTA ST	91335	3	189B121   301	2104006026	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.21392	-118.55141	09/05/2017 Changes to an approved set of plans. Changes have been made to reflect field conditions and revisions. *****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. Systems size is 14.4 kWac and consists of (2) inverters and (46) modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53263	15041-20000-21842	9025 N OAK PARK AVE	91325	12	198B133   636	2690005003	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.23519	-118.5058	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (20) micro-inverters, (20) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53264	16041-10000-41256	1860 W 38TH PL	90062	8	117B189   949	5035027025	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.01634	-118.31543	PV1 roof mounted solar system installation. installing 16 micro inverters rated at 320 watts each for a total system size of 5.12 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53265	11041-10000-18818	714 E TRACTION AVE	90013	14	127-5A215  41	5163012007	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM			PC Approved	09/12/2011 12:00:00 AM	ADDRESS	34.04535	-118.23623	T.I. TO AN EXISTING RESTAURANT.  PER APPLICANT, ALL EMERGENCY IS EXISTING AND NOT TO BE CHANGED.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53266	16041-20001-41846	1120 W 6TH ST Suite 103	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.05418	-118.26297	Revisions to approved set of plans.  Changes made to lighting system.  Approval for delta-6 revisions only.  (((FULL PLAN CHECK FOR A CHANGE OF USE FROM RETAIL TO GROCERY MARKET ON PROPOSED CORE AND SHELL SPACE. SCOPE INCLUDES A NEW 800-AMP BOARD, AND ALL NEW ELECTRICAL EQUIPMENT CONNECTING TO AN EXISTING 3000-AMP SERVICE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53267	19041-10001-34206	634 N ALMA REAL DR	90272	11	126B129   736	4411011009	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.03906	-118.52375	EXPEDITE FEESPV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 7.6KWac/10.8KWdc. SCOPE OF WORK INCLUDES 32 MODULES (LG340N1C-V5) WITH OPTIMZERS (SE P370) LEADING TO A CENTRAL INVERTER (SE7600A-US), WITH A BATTERY (LG CHEM RESU 10H) AND A CRITICAL LOADS PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53268	17041-10000-21881	1718 N LAS PALMAS AVE 1-224	90028	13	148-5A185  78	5547009009	C4-2D-SN / [Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			06/28/2017 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	11/20/2020 12:00:00 AM	ADDRESS	34.10226	-118.33601	PC FOR 6 STORY  MIX USED APARTMENT BUILDING TOTAL OF 224 UNITS WITH 4000-AMP 277/480V SERVICE. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53269	17041-10001-15738	10250 W SANTA MONICA BLVD STE. 2440	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	1st revision to apporved set noted under delta 4. Scope: add qty of fixture C; revise T24 info accordingly; increase the load size of AHU 1, 2, and 3. Permit is covered under master plan.<<Full Plan check for UCLA medical office located in Westfield Century City Ste#2440. Total area: 3,134 sq.ft, fed from MS-ELA11>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53270	19041-10000-14680	189 S THE GROVE DR #J/A	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC PWR AND ENERGY FOR FIRST TIME TI. EXISTING 600A,480/277V, 3PH SERVICE. SCOPE OF WORK AREA 11,505SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53271	11041-10001-12934	823-829 W EXPOSITION BOULEVARD N/R 111 &-210	90089	8	117B197   224	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	08/26/2011 12:00:00 AM	PIN	34.01877902	-118.28765493	Modification to an approved set of plans.  Plan check is for energy only.  <<<<T.I. for suites number 111 and 210.  Remdeling of the light fixtures.  Plan check is for energy only.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53272	10041-10000-18432	725 S FIGUEROA ST # 3250	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	12/26/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	REMODEL OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53273	14041-10000-01447	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR ENERGY. permit to be pulled at EPC counter only. NEW outdoor CANOPY AT LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53274	18041-10000-05067	1262 E PALMETTO ST 1ST FLR-SUITE 515	90013	14	126A217    44	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.04005	-118.23347	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A RETAIL AND OFFICE SPACE. TOTAL AFFECTED AREA IS 13,889 SQ FT. B#18016-10000-02462	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53275	13041-20000-09406	11726 W SAN VICENTE BLVD #240	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.05328	-118.46625	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53276	17041-30000-01796	801 S FIGUEROA ST #400	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Title 24 plan check only.  T.I. to 4th floor of commercial office highrise.  New lighting and receptacles to be supplied by existing subpanels.Building permit #16016-10000-30780	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53277	16041-20000-03268	21800 W BURBANK BLVD #100	91367	3	174B105    42	2146007122	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.17267	-118.60262	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,987 sq. ft.Note: Building application has been created under 16016-20000-01742	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53278	15041-20000-42205	3880 S SYCAMORE AVE	90008	10	117B177   314	5029001026	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	01/26/2016 12:00:00 AM	ADDRESS	34.01593	-118.35703	Plan check for PV roof mounted system. System size: 3.8kW with 15 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53279	13041-10001-02969	13764 W ALDERGROVE ST	91342	7	231B153    86	2582007003	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.32638	-118.43389	CHANGES TO APPROVED SET OF PLANS. ONLY CHANGES IS FOR AC DISCONNECT. PER INSPECTOR REQUEST, PC FOR CHANGE IN AC DISCONNECT ONLY. ORIGINAL PC # 13041-10001-02969PV1 for two story house. Total system size 11.03 KW DC. {Inverter used: Power one. Model#: PVI-3.6-OUTD-S-US} {Inverter used: Power one. Model#: PVI-6000-OUTD-S-US} {Solar Module used: Yingli Energy. Model#: YL245P-29B 245W}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53280	15041-10001-32566	1201 E 7TH ST	90021	14	126A213   652	5147034016	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Info Complete	08/17/2016 12:00:00 AM	ADDRESS	34.03762	-118.24209	PC FOR DELTA 8 CAHNES. ADDING NEW MICROWAVE CIRCUIT FOR ALL UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53281	16041-20000-25732	12732 W MARLBORO ST	90049	11	132B137   609	4405022016	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.05475	-118.48679	NEW 2-STORY SINGLE FAMILY DWELLING 800 AMP SERVICE.  PLAN CHECK ONLY FOR POWER -  ELECTRICAL PERMIT FEES PAID UNDER BUILDING PERMIT 14010-10000-01324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53282	19041-10000-24797	3756 W SANTA ROSALIA DR	90008	8	114B185   457	5032024014	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.00913	-118.33916	Plan check for removing HID fixtures and replace with new LED Fixture for outdoor area with a total lighting fixture of 50675-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53283	13041-10000-31125	6801 W HOLLYWOOD BLVD C3-343	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	TENANT IMPROVEMENT FOR A NEW RESTAURANT IN EXISTING SPACES. FULL PLAN CHECK FOR POWER AND ENERGY. NO UNDERGRD WORK. TWO NEW 1200A SERVICE PER APPLICANT. 33779 SQ FT OF ILLUMATED AREA (INDOOR + OUTDOOR).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53284	10041-10004-01492	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM	10/04/2011 12:00:00 AM		Permit Finaled	01/17/2012 12:00:00 AM	ADDRESS	34.09676	-118.29487	Modification to previously approved plans.  This modification is to install a disconnect ahead of the fire pump.  <<<<<<TI - existing church of scientology -highrise>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53285	14041-20000-30978	10205 N TELFAIR AVE	91331	7	204B161   330	2623011001	R1-1	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM			Corrections Issued	11/07/2014 12:00:00 AM	ADDRESS	34.25561	-118.41738	Roof mounted PV system with tranformerless inverter.  Total system size is 4.3KW.Note: The solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53286	19041-10001-09937	2600 S HOOVER ST BLD. A	90007	9	123A201   122	5123001900	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			06/03/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	02/17/2022 12:00:00 AM	ADDRESS	34.03132	-118.2838	[This set of plan covers plan check for both buildings] Full plan check for power and energy for alteration and minor addition and repair of existing SRO hotel building with 37 units total. Scope includes new 1600A service and all new equipment. Fully new electrical system. There are two building permits assigned to this property for two different building on the same lot with one electrical system serving both. Building B, C, D: B#18016-10000-31040: Conversion of existing historic 46 units into 27 units of low income housing and supportive services.  New elevator to be provided.Building A: B#18016-10000-31043: Conversion of existing historic 9 guestrooms into 10 unit of low income housing and supportive services.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53287	19041-20000-01860	22721 W KITTRIDGE ST	91307	12	180B097   149	2038021015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Issued	01/16/2019 12:00:00 AM	ADDRESS	34.19163	-118.62248	Plan check for a PV1 roof-mounted PV system. System size is 9.1 kWdc/8.5 kWac-CEC and consists of (1) 7.6 kWac rated inverter, (28) modules, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53288	19041-10000-47445	1440 E 41ST ST	90011	9	115-5A211 269	5116011027	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	ADDRESS	34.00855	-118.24796	NEW ROOFTOP SOLAR INSTALLATION. SYSTEM SIZE 22.78KWdc (15.2KWac) USING 68 QP335 MODULES, 68 SE P370 OPTIMIZERS & 2 SE7600H-US CENTRALS INVERTERS. CONNECTED TO AN EXISTING 400Amp SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53289	17041-10000-20037	902 S 4TH AVE	90291	11	108B145   604	4239010022	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			06/14/2017 12:00:00 AM			Reviewed by Supervisor	06/20/2017 12:00:00 AM	ADDRESS	33.99368	-118.47158	Installation of new roof mounted solar PV system on existing 3 unit residential building.  Central inverter system.  Total size = 3 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53290	16041-20001-34735	4259 N TARZANA ESTATES DR	91356	3	165B117   340	2178005095	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	34.14732	-118.56407	EXPEDITED PLAN CHECK FEE PER APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53291	19041-10001-19099	13262 W GALEWOOD ST	91423	4	162B157   331	2385006034	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.14224	-118.42152	(EXPEDITE FEE) PC FOR PV-1, SYSTEM CONSISTS OF 1600SF TESLA SOLAR TILE, 4 INVERTERS (SOLIVIIA(1)3.8AND (3)7.6) , 1 200AMP LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53292	11041-10000-10026	3060 S CRENSHAW BLVD	90018	10	120B185   804	5051029029	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			05/17/2011 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.02579	-118.33489	Core & Shell for a commercial Bldg. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53293	10041-20000-21244	10880 W WILSHIRE BLVD #2020	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM			PC Approved	10/25/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check T-24 energy general and emergency lighting for office TI for suite #2020	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53294	14041-20000-13266	8576 N LIMERICK AVE	91306	3	195B109   435	2780017009	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.22668	-118.58316	PV1 SINGLE FAMILY DWELLING. 4 MICROINVERTERS. USING ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53295	15041-20000-43900	4183 S NORMANDIE AVE	90062	8	114B193   946	5021016040	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Expired	02/14/2018 12:00:00 AM	PIN	34.00744303	-118.30051295	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (20) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53296	17041-30000-29300	170 S GLESS ST	90033	14	127-5A219  27	5172003042	RD3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.04542	-118.22293	Plan check for Title 24 only, total load is less than 400A  new 2 story school. Total area: 18,263 sq ft. Building Application # 17041-10000-01410	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53297	15041-20000-30761	10727 W WILSHIRE BLVD	90024	5	132B153   123	4360033***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			09/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Expired	10/13/2017 12:00:00 AM	ADDRESS	34.06081	-118.43692	Plan check for power only.  Installation of new distribution board for installation of new car chargers in existing highrise residential building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53298	11041-10000-27718	621 W 152ND ST BLDG J	90247	15	072B201    75	6120001017	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM			PC Info Complete	08/28/2012 12:00:00 AM	ADDRESS	33.89472	-118.28668	Existing 2000A service. Plan check for new feeder supplying two service rated disconnects and disconnect for future equipment control panel in Building J. Building K under #12041-20303. Installation in Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53299	15041-10000-18838	542 S ALAMEDA ST	90013	14	126A215   141	5163027011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	06/17/2015 12:00:00 AM	ADDRESS	34.04014	-118.23809	TI-24 PC FOR ENERGY TO AN (E) COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING, NEW EQUIPMENT AND A 400 AMP SERVICE UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53300	15041-20000-33041	225 N VERMONT AVE	90004	13	138B197   512	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.07529	-118.29188	Plan check for Title 24 only. Project site is a new 100-unit apartment. Project scope is outdoor lighting only. Total outdoor lighting area = 6,845 sq. ft.Note: Building application has been filed under application 15010-10000-01132	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53301	16041-10000-13962	841 E MILWOOD AVE	90291	11	108B145   146	4241007031	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	33.99551	-118.46155	PV1, rooftop solar installation with AC modules (18) SPR-E20-327-C-AC .    Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53302	17041-20000-07615	9401 N DE SOTO AVE ste b	91311	12	198B109    69	2746008007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.24091	-118.58876	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.  total square footage 3013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53303	19041-10000-38615	11418 W MOORPARK ST	91602	2	165B169   284	2365015013	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Issued	09/26/2019 12:00:00 AM	ADDRESS	34.15023	-118.37969	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53304	12041-10000-27311	4371 S WESTLAWN AVE	90066	11	108B157   691	4231014030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	33.9927	-118.42644	ENPHASE MICROINVERTER STANDARD PLAN. ROOF MOUNTED PV1 SOLAR INSTALLATION. SYSTEM SIZE IS 4.16 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53305	18041-20000-42786	6171 N SEPULVEDA BLVD STE. A1	91411	6	177B145   355	2242001026	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.18246	-118.46651	Full Plan check for First Time Tenate ATT Retail new panel lightings and receptacles. Total area: 1705 sq ft.B#18016-20000-36149	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53306	13041-10000-32260	1914 S BUNDY DR	90025	11	123B149   282	4259020013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.03484	-118.45635	Fire alarm for 2 story la fitness center. 95 devices and  one panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53307	14041-20000-04664	4714 S LINCOLN BLVD	90292	11	105B153   149	4224014018	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	33.98016	-118.43828	PLAN CHECK FOR T24 PART 6 ENERGY ONLY IN A 1,971 SQ FT COMMERCIAL BUILDING. SCOPE OF WORK < 400A. WORK ALSO INCLUDES EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53308	18041-10000-32762	11076 N NORRIS AVE	91331	7	210B161   417	2534026031	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.27154	-118.41726	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53309	19041-10000-52775	10045 W RIVERSIDE DR	91602	4	165B181    22	2424008036	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	05/13/2020 12:00:00 AM		Permit Finaled	02/04/2021 12:00:00 AM	ADDRESS	34.15237	-118.34981	NEW TENANT. INSTALLING PANELS, LIGHTS, LOADS, ETC. Affected area: 11,081 SFT.Building Permit: 19014-10000-06518	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53310	16041-20000-31782	9070 N VAN NUYS BLVD	91402	6	198B149   582	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.23513	-118.45006	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,812 sq. ft.Note: Building application has been generated under 16016-20000-21098	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53311	13041-10001-24724	13224 W FERNMONT ST	91342	7	222B157   295	2512006042	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.30504	-118.42122	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53312	16041-10000-30445	811 W WILSHIRE BLVD 15TH FLR	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	"PC FOR TI. TITLE-24 ENERGY ONLY,  ENERGY ONLY.  A HIGH RISE ENTIRE 15TH FLOOR. TOTAL AREA OF 14595 SQ.FT.SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. ALSO, 2 NEW PANELS WITH TOTAL LOAD OF <150A.REFER TO BUILDING APPLICATION 16016-10000-12892Full floor, approximately 14,480 sq ft, tenant improvement on the 15th floor of an existing office building to include new ceiling, finishes, partitions and mill work.  NO CHANGE IN USE OR PARKING.  ""COMPLY WITH DEPARTMENT ORDER effective date 9/01/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53313	15041-20001-01131	15994 W FILBERT ST	91342	7	228B141    46	2603023046	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2015 12:00:00 AM			PC Approved	01/20/2015 12:00:00 AM	ADDRESS	34.32469	-118.48312	Expedited per customer request.PV1. Install roof mounted PV system sized 8.8 kW. Interconnected with main service pannel.(26) Sunpower SPR-E20-327 modules(1) SMA SB 5000 TL inverter(1) SMA SB 3800 TL inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53314	16041-10000-32076	13859 W RUNNYMEDE ST	91405	2	186B153   246	2215007001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.20585	-118.43538	PV, NEW 11.2 KW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (40) MODULES: SUNIVA OPT280-60-4-1B0(40) MICROINVERTERS: ENPHASE M250-60-2LL-S22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53315	13041-20000-35751	13653 W CANTARA ST	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.21997	-118.43062	"Replacement Emergency Generator for a 5-story outdoor parking structure for Kaiser Permanente.  New Generator will serve the ""North"" parking structure and the ""North 1 MOB"".  Connection to North 1 MOB is on application #13041-20000-35757 (E13VN02687)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53316	16041-10000-21591	635 E 118TH PL	90059	15	084B205   795	6084004026	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.92566	-118.26393	PV1, rooftop solar installation 3.6 kW AC system.   (16) KU2656ZPA   (1)  PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53317	14041-10000-34867	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.05069	-118.24861	Title 24 plan check only.  Total area = 700 sq. ft. Lighting T.I. to existing restaraunt space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53318	13041-10000-00821	6623 N BLEWETT AVE	91406	6	180B141   343	2233012023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	ADDRESS	34.19093	-118.4784	PV1 SINGLE STORY HOUSE 10.78 KW DC.  44 PV MODULES.  2 CENTRAL INVERTERS.[MODULES: SOLAR PV MODULE YINGLI ENERGY {YL245P-29B}][INVERTER: POWER-ONE-PVI-4.6-I-OUTD-S-US-NG]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53319	16041-10001-30421	19903 W GRESHAM ST	91324	12	195B113   179	2782033027	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			PC Approved	10/13/2016 12:00:00 AM	ADDRESS	34.23095	-118.56693	EXPEDITED RSES PLAN CHECKING PER APPLICANT REQUEST.<<<PV1, INSTALL 14.715 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(45) MODULES: SUNPOWER-SPR-e20-327-C-AC(45) MICROINVERTER>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53320	15041-10000-24075	1500 W PACIFIC COAST HWY Bldg L	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FA SYSTEM FOR A New 3-story, 20 unit apartment with garage, 53 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53321	13041-10000-00730	601 N VIRGIL AVE	90004	13	141B197   743	5539025014	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			01/10/2013 12:00:00 AM			PC Info Complete	01/11/2013 12:00:00 AM	ADDRESS	34.08187	-118.287	T24 for existing grocery store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53322	16041-20000-40360	7235 N ROCK RIDGE TER	91307	12	186B089   710	2027023032	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	12/19/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.20261	-118.65062	__low permit fee due to senate bill 1222 from 2012....PV1.  Install 15.2 kW DC roof-mounted grid-tied PV system.  (44) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53323	19041-10000-12882	152 W PICO BLVD	90015	14	124-5A207  34	5133001003	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM			PC Info Complete	10/29/2019 12:00:00 AM	ADDRESS	34.03719	-118.26166	Full plan check for power and energy.  Scope includes new lighting and equipment (1000-Amps service)  with a total area of 14,183-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53324	15041-10001-20096	12073-12075 W VENTURA PL	91604	2	165B165  1214	2368002013	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM			PC Approved	09/04/2015 12:00:00 AM	ADDRESS	34.14489	-118.39502	Changes to approved set.  Change of architectural layout.  (((Title 24, plan check for energy. TI existing coffee shop to ice cream shop. total square footage is 1010.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53325	19041-20001-29520	1745 E 7TH ST	90021	14	124-5A215  58	5164022012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.0349	-118.23475	"10/31/19CHANGES TO APPROVED SET DELTA ""G"" ONLY.<<<addition of new 600 amp distribution board (restaurant distribution) fom an existing service MSA.  plan check for power only.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53326	14041-10000-07016	926 N CITRUS AVE	90038	4	144B185  1081	5532012030	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.08787	-118.33954	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR PARKING LOT. OUTDOOR LIGHTING. 5770 ILLUMINATED HARDSCAPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53327	13041-10000-05912	146 N CORONADO ST	90026	13	136-5A203  24	5157009010	RD5-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			03/06/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.07021	-118.27498	PV2 FOR 2 STORY 4 UNIT APARTMENT BUILDING. TOTAL SYSTEM SIZE: 6.86 KW. 28 MODULES AND 4 INVERTERS WITH NEW MAIN SERVICE ENTRANCE AND METER SECTION UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53328	13041-20000-15025	6087 W SUNSET BLVD	90028	13	147A189    49	5545008002	[Q]C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Expired	07/07/2015 12:00:00 AM	ADDRESS	34.09819	-118.32178	"Plan check is on 13041-20000-04836. This application was created to separate job into two permits (two buildings). Permit fee is under ""inspection"" fee period."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53329	18041-10001-02694	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.02174	-118.39786	DELTA 1 CHANGES T THE APPROVED PLANS. Reduce feeder to Panel A1 to 200 Amp and add a 90KW water heater.<<<<FIRST TIME OCCUPANCY IN UNIT #103.CHANGE OF USE FROM RETAIL TO DANCE STUDIO, EPC FOR POWER AND ENERGY.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53330	19041-20000-09256	7569 W MELROSE AVE	90046	5	141B177   580	5526013024	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.08381	-118.35502	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53331	15041-20000-31845	2801 S BRIGHTON AVE	90018	8	123B193  1046	5053029035	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.02986	-118.3017	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53332	17041-10000-00277	19400 W VENTURA BLVD	91356	3	174B117   334	2163002059	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.17246	-118.5559	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA (OUTDOOR) 26700 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53333	17041-20002-31585	20631 W GRESHAM ST	91306	3	195B109   104	2780009005	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.23071	-118.58299	06-07-2018 Changes to an approved set of plan. Changes include relocate load to main panel. Changes has been clouded.Plan check onlyFees$0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53334	16041-10000-43108	5575 N WOODMAN AVE	91401	4	174B157   608	2247001017	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.17176	-118.43146	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total area:11,550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53335	14041-10000-08076	216 N JOY ST	90042	1	150A225   165	5467029005	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1851.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.10572	-118.204	PV1 2.25KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(9)modules: {Canadian Solar {CS6P 250PX}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53336	12041-10000-20480	12115 W BLUFF CREEK DR	90094	11	105B165   936	4211010064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	33.97884	-118.4045	Change to lighting and receptacles for an existing two-story office building.  Load is less than 200Amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53337	19041-20001-30918	4208 N ALLOTT AVE	91423	4	165B157   924	2373009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.14616	-118.4281	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CHANGE ON SINGLE LINE DIAGRAM, CHANGING FROM FULL HOUSE BACKUP TO PARTIAL BACK UP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53338	19041-20000-05908	17438 W HATTERAS ST	91316	5	174B129   231	2254022002	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.17603	-118.5136	PV1.  Install 8.775 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (27) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53339	17041-10000-37036	1149 S BROADWAY 9TH FL	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Issued	10/16/2017 12:00:00 AM	ADDRESS	34.03859	-118.26015	REPLACING  8 EA FLUORESCENT 2X2 TROFF LUMINAIRES WITH LED TYPES IN THE RECEPTION/MULTI PURPOSE OPEN AREAPLAN CHECK  IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53340	16041-10000-12080	5735 W ADAMS BLVD	90016	10	123B173   824	5048005039	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.03262	-118.36814	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 17.00KWac INTERCONNECTED WITH MSP (SINGLE PHASE SYSTEM).(68) SOLARWORLD 285 MODULES(68) ENPHASE 250 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53341	16041-10000-19307	1027 S PLEASANT VIEW AVE	90291	11	108B145    91	4239017027	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	33.99591	-118.46343	PV1, INSTALL  4.25 KW DC ROOF-MOUNTED SOLAR ARRAY FOR A SINGLE FAMILY.(13) MODULES: SUNPOWER SPR -327NE(1) INVERTER: SMA SB -3800TL-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53342	18041-10000-40295	7843 N LANKERSHIM BLVD	91605	6	189B169   517	2310025***	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	NEW COMMERCIAL  ROOFTOP SOLAR SYSTEM CONSIST OF 42 MODULES (HANWHA Q PEAK-L-G4.2 365) AND 21 MICROINVERTERS (AP YC-600).  SYSTEM SIZE IS 15.33KWdc and 12.6KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53343	18041-20000-41154	242 N ADERNO WAY	90272	11	126B121   440	4415032013	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.04189	-118.54541	Plan check for a PV1 roof-mounted PV system. System size is 8.91 kWdc/8.5 kWac and consists of (27) modules, (27) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53344	19041-10000-34630	1126 S WESTWOOD BLVD	90024	5	132B153   211	4363022006	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.06019	-118.44486	PC for energy only, scope of work is replacing lights in a wax rooms to LED. Total affected area is 480 sqft. All controls and circuits are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53345	15041-10000-38985	701 E 3RD ST	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	PIN	34.04581508	-118.23784015	TI TO AN EXISTING COMMERCIAL BUILDING.  RELOCATING 16 PANELS INTERSECTING EXISTING FEEDER FROM EXISTING SWITCHGEAR.  NEW OPTIONAL STANDBY GENERATOR 80KW.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53346	10041-10000-02980	1340 W STORM PKWY	90501	15	045B193   784	7347018077	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			02/19/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	06/14/2010 12:00:00 AM	ADDRESS	33.81676	-118.30128	T.I. for a warehouse.  Install general and emergency lightings in office, restroom, and lounge rooms.  Plan check for Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53347	17041-20000-11351	5446 N IRONDALE AVE	91367	3	174B109   617	2151032070	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.16998	-118.58526	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD ACM PLAN. SYSTEM SIZE: 4.16 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53348	13041-20001-21029	16800 W LABRADOR ST	91343	12	201B137   288	2686001024	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.24918	-118.49823	((8/6/2013 EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 7.848KW. 24 MODULES AND 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53349	19041-10000-08382	3656 E NOAKES ST	90023	14	117A227    89	5192017003	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Info Complete	09/12/2019 12:00:00 AM	ADDRESS	34.01419	-118.198	FULL PC FOR POWER AND ENERGY. CHANGE FROM WAREHOUSE TO MANUFACTURING, STORAGE, INDOOR CULTIVATION. NEW PANELS CONNECT TO EXISTING 2500A, 27/480V, 3PH, 4W SERVICE. TOTAL AFFECTED AREA IS 25635 SQ. FT.  B#19016-10000-06628	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53350	18041-10000-19586	6430 W SUNSET BLVD #1105	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.09782	-118.32979	T-24 PC ENERGY ONLY FOR A TENANT IMPROVEMENT TO AN OFFICE SPACE. SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA 1837.6 SQ.FTB# 18016-20000-09234	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53351	11041-10000-15164	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM			Corrections Issued	08/14/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I.  Remodel of the lights in the dining terrace only.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53352	10041-10000-14763	10250 W SANTA MONICA BLVD # 45	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Ti in a retail space. Plan check for T24 & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53353	18041-20000-04740	11335 W DONA DOROTEA DR	91604	2	156B169    99	2381007029	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	08/11/2018 12:00:00 AM	ADDRESS	34.12722	-118.38066	Plan check for power only. Project scope is the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53354	15041-20000-07926	13202 W WEDDINGTON ST	91401	4	171B157   465	2345027008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Expired	04/12/2017 12:00:00 AM	ADDRESS	34.16611	-118.4203	Plan check for PV1 roof mounted system with 5.0kW inverter and 24 modules(2 strings)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53355	19041-20000-41768	5460 N WHITE OAK AVE	91316	5	174B129   929	2257019259	R3-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Apartment			10/15/2019 12:00:00 AM	03/13/2020 12:00:00 AM		Issued	03/13/2020 12:00:00 AM	ADDRESS	34.17036	-118.51819	1000A 240/120V 1ph-3w service upgrade to (E) building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53356	18041-20000-24408	20732 W SPRUCE CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.29481	-118.58573	Plan check for PV roof mounted system, system size: 4.2kW with 12 AC Modules .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53357	17041-10000-35950	1424 S MANHATTAN PL	90019	10	129B193  1559	5073010019	R2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.04556	-118.30998	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53358	13041-10000-28246	5066 W HOLLYWOOD BLVD	90027	13	147B197   266	5543001002	[Q]C2-2D	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Info Complete	05/15/2014 12:00:00 AM	ADDRESS	34.10162	-118.30008	Change of use from retail to restaurant (Hoy-Kay Thai).  Install new 200A service, panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53359	13041-10000-32942	6941 N JELLICO AVE	91406	6	183B129   656	2229001004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Expired	01/19/2016 12:00:00 AM	ADDRESS	34.19674	-118.51752	PV1, Install  4 kw DC roof-mounted solar array for a 1 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 16 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53360	15041-10000-04243	6622 W HOLLYWOOD BLVD	90028	13	148-5A185 132	5547015028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			Reviewed by Supervisor	03/18/2015 12:00:00 AM	ADDRESS	34.10138	-118.33408	Plan check for power and Title 24 (energy).  Total area = 10,703 sq. ft.Renovation of existing mixed use building to office space.  New 800 A service and power distribution equipment.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53361	19041-10001-33054	11966 W WAGNER ST	90230	11	108B161   222	4218007001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	33.99441	-118.41666	NEW 12KW ROOF MOUNTED PV SYSTEM WITH 39 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53362	17041-20000-11698	17606 W CHATSWORTH ST	91344	12	207B129   472	2733009010	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Info Complete	04/18/2017 12:00:00 AM	ADDRESS	34.26463	-118.51788	ti to an existing commercial building.  adding new lighting new controls to new panels.  plan check for energy and em lighting only.  total quare footage 1827.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53363	16041-10000-38304	501 W EL SEGUNDO BLVD SPC 102	90248	15	081B201   259	6132002024	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Issued	10/31/2016 12:00:00 AM	ADDRESS	33.91659	-118.28337	PC FOR TITLE 24. ENERGY ONLY IN COMMERCIAL BUILDINGSCOPE INCLUDES NEW LIGHTS AND  RECEPTACLES. TOATL  AFFECTED AREA 1104 SQ,FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53364	15041-10002-01072	12534 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.97822	-118.412	((((5/10/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO ENERGY CALCULATIONS, OCCUPANCY SENSORS AND LIGHTING SWITCHES.  THE CHANGES APPLY TO ALL THE FOLLOWING APPLICATION NUMBERS AS NOTED BELOW.Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant).Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53365	15041-10000-20828	1925 S CENTURY PARK EAST suite 400	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMS.  PLANCHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 3291. SCOPE OF WORK TO BE PERFORMED IN 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53366	18041-10000-38396	6928 N OWENSMOUTH AVE	91303	3	183B105   755	2138007027	(Q)P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.19636	-118.60139	Remove indoor HID fixtures and replace with new LED fixtures - T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53367	19041-10000-45547	13385 W INWOOD DR	91423	4	162B157   674	2373027028	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.13958	-118.42471	$0 FEE PER AB1414 [EPLAN] NEW ROOF-TOP SOLAR INSTALLATION. SYSTEM INCLUDES 36 (Q.PEAK DUO BLK-G5 315) MODULES,  36 POWER OPTIMIZERS (SOLAR EDGE P400 ZEP),  1 CENTRAL INVERTER (SOLAR EDGE SE 10000A-US), 2 ENERGY STORAGE SYSTEMS (TESLA POWERWALLS),  CONNECTED TO A NEW 225A MAIN SERVICE. SYSTEM SIZE: 11.34KW DC,  10.0KW AC.MAIN PANEL UPGRADE UNDER SEPERATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53368	15041-20001-03319	11111 N BECKFORD AVE	91326	12	210B121   294	2718003011	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.27217	-118.54893	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.3KW INTERCONNECTED WITH MSP.(25) E20-327NE SUNPOWER MODULES(2) SPR INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53369	16041-10000-05554	600 WORLD WAY SP 643-644	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR ENERGY AND POWER. FIRST TIME TENANT. SMALL BAR(EARTH BAR) IN LAX TERMINAL 6. TOTAL AREA 335 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53370	19041-20000-27923	21031 W VENTURA BLVD Suite 700	91364	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.16693	-118.5916	Plan check for Title 24 only. Project site is an existing commercial tenant space in a high rise building. Project scope is a tenant improvement. Total lighting area = 7,047 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53371	18041-10000-41257	5162 S MANHATTAN PL	90062	8	108B193   110	5005029012	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	04/20/2019 12:00:00 AM	ADDRESS	33.99561	-118.31001	NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 2.4K Wdc/2.24K Wac.THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PEFORFANCE METTER AND A METER ADAPTER. (8) MODULES-SOLARWORLD SW 300 (8)MICROINVERYTERS-ENPHASE S280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53372	14041-10000-01885	5032 N EAGLE ROCK BLVD	90041	14	162A223   211	5686004031	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.13787	-118.21419	PLAN CHECK FOR TITLE 24 ENERGY. FOR A NEW BUILDING. 2 OVERNIGHT PARKING SPOTS  AND MEZZANINE WITH OFFICE. [[METHANE BUFFER ZONE. NO PENETRATION FOR ELECTRICAL WORK.]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53373	15041-10001-07589	123 S FIGUEROA ST	90012	14	132A211     6	5151001026	C2-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.05725	-118.25278	Changes to approved set.  New lighting fixture layout and remove photocell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53374	13041-10002-07994	8985 W VENICE BLVD CB-2	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.02733	-118.39241	Modification to previously approved drawings.    <<<<RENOVATION OF EXISTING STARBUCKS. CHANGE IN LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53375	15041-20000-00991	4322 S FIGUEROA ST	90037	9	114A201   377	5019029027	C2-1VL	South Los Angeles	Southeast Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM			PC Info Complete	01/13/2015 12:00:00 AM	ADDRESS	34.00485	-118.28251	TI to an existing single storing commerical building (Rite Aid). Adding new lighting and controls to existing pannel. Plan check for energy and emergency lighting. Total sqft. 3262. Scope of work to be in storage and pharmacy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53376	11041-20000-14726	5700 W WILSHIRE BLVD suite 350	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	ADDRESS	34.06218	-118.35303	Ti in an existing office. EPC is for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53377	14041-20000-19412	12813 W LEAGUE ST	91605	2	189B161   224	2305008006	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.21728	-118.41235	Standard Plan: 5.72KW PV1 roof-mounted system with (22) Rec Solar 260PE modules and a Power One PVI 4.2-OUTD transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53378	14041-20000-13665	20816 W CAMPANIA LANE	91326	12	213B109   402	2701068013	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.27972	-118.58661	6.33KW PV1 roof-mounted system with (28) Yingli YL250P modules and a PVI-6000-OUTD-US transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53379	18041-20000-27536	9089 N GLENOAKS BLVD	91352	6	195B173    67	2408032025	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM			PC Approved	07/23/2018 12:00:00 AM	ADDRESS	34.23402	-118.37115	New 400A 240/120V 1ph-3w service and tenant improvement to (E) service station.  Plan check for energy only.  Fuel dispensers and associated wiring (E) to remain - scope of work does not include any wiring passing through classified hazardous locations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53380	12041-10000-00346	3400 W 6TH ST 309-311	90005	10	135B197  1012	5502028018	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM			PC Info Complete	03/30/2012 12:00:00 AM	PIN	34.06339483	-118.29573965	Installing new 125 kva gen set, and 7 new feeders, new DP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53381	13041-20001-29370	4614 N MIRADOR PL	91356	3	168B121   470	2176032011	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2013 12:00:00 AM			PC Approved	11/01/2013 12:00:00 AM	ADDRESS	34.15412	-118.54778	((Expedite fees only))PV1 10.92 KW NEGATIVELY GROUNDED SYSTEM. 42 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53382	13041-10000-36168	1007 S SAN JULIAN ST	90015	14	124-5A211  35	5145019012	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.03677	-118.25253	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53383	11041-10001-21019	321 S SERRANO AVE PV1	90020	10	135B193   284	5503004015	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2012 12:00:00 AM			PC Approved	04/24/2012 12:00:00 AM	ADDRESS	34.0683	-118.30702	ROOF MOUNTED SOLAR (44) PANELS 8.36 KW SYSTEM, 621.65SQFT. *UPGRADED SERVICE TO 125A. Solar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.Note that an electrical permit was obtained earlier.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53384	12041-10001-24316	448 S HILL ST Basement	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.04896	-118.25139	plan check for energy only. CHANGES TO APPROVED PLANS: FIXTURE LAYOUT AND SPECS CHANGED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53385	16041-20000-29463	830 N FAIRFAX AVE BLDG B	90046	5	141B177    97	5527002032	C2-1VL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.08635	-118.36121	PLANCHECK FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT. TWO BUILDINGS IN ON PLAN.  BUILDING B	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53386	16041-10000-18056	380 W WORLD WAY LVL. 3-#T04	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	PC for Power and Energy.  TI to an (E) commercial space inside the Tom Bradley Int'l airport Level.3 Ste. T04.  New connected load > 400A.  Total area: 2,713 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53387	10041-10000-22489	2323 E OLYMPIC BLVD	90021	14	121-5A217 342	5167001036	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM			PC Approved	11/12/2010 12:00:00 AM	ADDRESS	34.026	-118.23134	"Ti in an existing commercial building. Plan check is for T24 and Emergeny lights. ""COMPLY WITH DEPARTMENT ORDER effective date  11/24/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  Permit was issued under #10041-10000-21221."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53388	13041-10001-32861	500 W WORLD WAY TERMINAL-5-EXIT STAIR	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM			PC Info Complete	01/31/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	pc for energy only. plan check per applicant request. less than 400A connected load.see inspection fees. permit to be pulled at EPC counter only. Includes the addition of an exit stair on teh east side of terminal 5 that will provide a means of egress from teh sky club and concession levels to teh apron level. exit stair 31a will serve as a replacement egress stair once stair 32 is removed for the restroom renovation project. which is being submitted as a concurrent design package. this project also includes the addition of exit stair #50.52.54.55. also included is teh relocation of eelctrical conduits in conflict with the new stairs. the electrical work will include new exterior light fixtures with new exit signs, fire alarm pull station and acams at new exit doors.original description: pc for energy? permit to be pulled at EPC counter only.LIGHTING WORK FOR TERMINAL 5 OUTDOOR EXIT STAIRS(ADDITIONED TO AN EXISTING BUILDING). CONDUIT-REROUTING TO GO AROUND THE ADDED EXIT STAIR WAYS.PER APPLICANT REQUEST, THE PLAN WAS SUBMITTED AND EXPEDITED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53389	17041-10006-00340	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.16326	-118.37388	PLAN CHECK FOR CHANGES TO APPORVED SET OF PLAN (DELTA 11 CHANGES ONLY)- CHANGES INCLUDE MODIFICATION TO EMERGENCY SYSTEM,  ALTERATIONS TO EXISTING LIGHTING PLAN, NEW PANEL AND MODIFICATION OF EXISTING CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53390	14041-20000-09024	15954 W BLYTHE ST	91406	6	189B141   107	2206007020	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.21468	-118.48108	PC FOR FIRST TIME TENANT - COMMERCIAL MACHINE SHOP.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53391	17041-10000-41461	8631 S STANMOOR DR	90045	11	096B157   645	4119002026	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			Reviewed by Supervisor	12/22/2017 12:00:00 AM	ADDRESS	33.95887	-118.4251	PC FOR A NEW FIRE ALARM SYSTEM IN EXISTING SCHOOL WITH VOICE EVACUATION SYSTEM. SCOPE INCLUDES 3 FA PANELS, AND 157 FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53392	14041-20000-09213	11916 N DUNNICLIFFE CT	91326	12	216B125   177	2870021026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.28811	-118.53668	PV1.   INSTALL ROOF MOUNTED PV SYSTEM SIZE 13KW INTERCONNECTED WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS MODEL# SE5000A AND SE6000A.   $0.00 PERMIT DUE TO SENNET BILL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53393	13041-20000-28946	5620 N WILBUR AVE 302,317,-319/322	91356	3	174B121   416	2160002042	(Q)CR-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.17273	-118.54456	NEW DENTIST NOT STATE LICENSED, NOT CHECKED FOR OSHPD3.   EXISTING 2000AMP SWITCHBOARD. EVERYTHING ELSE IS NEW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53394	16041-10000-00711	1130 E 55TH ST	90011	9	108B209   803	5104017014	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	33.99284	-118.25556	PV1 roof mounted installation to a single family home. Inverter rating: 3.6 kw, (16) Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53395	18041-10000-08249	9745 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	34.24644	-118.41942	Alterations for a Chase bank-replacing indoor and outdoor luminaires with Led type using existing branch circuits.total affected 1512 sq. ft. Plan check is for title 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53396	11041-20000-13333	5404 S JANDY PL	90066	11	105B161   885	4211006004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			PC Approved	06/27/2011 12:00:00 AM	ADDRESS	33.98159	-118.41622	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR TENANT IMPROVEMENT OF EXISTING OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53397	13041-20000-10046	1050 W CHILDS WAY Basement	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM			PC Approved	04/19/2013 12:00:00 AM	ADDRESS	34.02262	-118.29103	13041-20000-10046Change to lighting and receptacles in an existing USC Laboratory.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  (No Emergency lighting per applicant.)  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53398	10041-10000-03557	125 S SWEETZER AVE	90048	5	138B173   715	5511017012	R3-1-O	Central	Wilshire	Mid City West		2146.00, 2148.00	Electrical	Electrical	Apartment			03/01/2010 12:00:00 AM	03/01/2010 12:00:00 AM		Permit Finaled	08/18/2010 12:00:00 AM	ADDRESS	34.07359	-118.37026	New fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53399	16041-20000-04868	990 W 190TH ST 1 st Fl	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	33.85813	-118.29505	Plan check Title 24 only for existing  highrise building  1st main Lobby. Total area: 1,682 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53400	19041-20000-01455	4157 S MARCASEL AVE	90066	11	111B157   683	4233015010	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	33.99967	-118.42206	Installation of (2) Tesla battery back up (ESS) 5 kW each to an existing PV system.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53401	10041-10000-08726	705 W 9TH ST 1st floor	90017	9	129A207   265	5144021040		Central				2077.10	Electrical	Electrical	Apartment			05/11/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	08/19/2010 12:00:00 AM	ADDRESS	34.04607	-118.2616	Remodel of the common area on the 1st floor of  an appartment building.  Plan check for T24 and emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53402	19041-30000-38390	4751 W WILSHIRE BLVD Suite 310	90010	4	135B185   565	5505001021	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.06219	-118.3337	Plan check for energy only, Interior, non-structural tenant improvement to the 3rd floor of (E) office building Scope of work includes new lighting and receptacles. Total sq. ft. 5547.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53403	19041-10000-30747	3201 W 6TH ST	90020	10	135B197   956	5502024009	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.01	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	05/05/2021 12:00:00 AM	ADDRESS	34.06376	-118.29222	PLAN CHECK FOR POWER AND ENERGY FOR (E) RETAIL EXAM ROOMS. SCOPE OF WORK INCLUDES NEW LOADS AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53404	18041-10000-48854	936 N WESTERN AVE	90029	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Issued	12/27/2018 12:00:00 AM	ADDRESS	34.08749	-118.30896	TI in an existing commercial area. Install new lights. 1946 Sqr Ft. T-24 Only.Building Permit: 18016-10000-41087	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53405	18041-10000-19378	9241 N VALJEAN AVE	91343	12	198B137   635	2676018027	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Issued	05/24/2018 12:00:00 AM	ADDRESS	34.23871	-118.48735	INSTALL A NEW 8.85KW / 30 MODULES PV SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53406	18041-20000-41617	345 N FULLER AVE	90036	5	138B181   195	5526037005	R1V2-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.07756	-118.34995	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53407	17041-10000-28801	11047 N DE SOTO AVE	91311	12	210B109   544	2706001045	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.01	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.27142	-118.58911	T-24,  PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 55975 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53408	19041-20000-01155	5333 N LOUISE AVE pv1	91316	5	171B133   800	5594004018	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Issued	01/10/2019 12:00:00 AM	ADDRESS	34.16821	-118.51004	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53409	16041-20001-21211	10343 W DIAMOND ST LOT 10	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53410	18041-10000-00980	12101 N DRONFIELD AVE	91340	7	216B161    87	2514019025	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.28922	-118.4168	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 150500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53411	13041-20000-01499	6710 W 85TH PL	90045	11	096B161   596	4112029013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	33.96029	-118.40771	Photovoltaic system on roof of single family dwelling using a transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53412	18041-20000-41609	16940 W DEVONSHIRE ST	91344	12	204B133   217	2685002016	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.25735	-118.50161	ti to an existing commercial space.  adding new lighting new controls to exising panels.  plan check for indoor energy only.  Plan check only - permit issued separately under 19041-90000-43239.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53413	18041-10001-10693	647 S SAN PEDRO ST	90014	14	126A213    23	5148025009	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			09/17/2018 12:00:00 AM			PC Approved	09/17/2018 12:00:00 AM	ADDRESS	34.04132	-118.24643	[This is plan check only, permit is covered under master plan #18041-10000-10693]  Supplemental plan check to approved set of plan, changes noted as Delta-1. Scope includes: Replacing all units panelboard and reusing existing series rated breakers, to show kitceh homerun per panel schedule. Loads and other information remain the same. <<Plan check per applicant request. Plan check for power and residentail lighting requirements. Addition of load to each unit and new lighting in each dwelling units.B#18016-10000-08890>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53414	18041-10000-22037	6300 W WILSHIRE BLVD 1ST FLR.	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.06319	-118.36591	****SEE NOTE*****PC FOR CHANGE OF USE TI FROM OFFICE TO GYM IN A HIGH RISE BUILDING FOR TITLE-24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, EQUIPMENT CIRUCITS AND LIGHTS. TOTAL AFFECTED AREA 3794 SQ.FT B# 18016-10000-21939	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53415	16041-10000-41177	732 S SPRING ST	90014	14	127-5A211 168	5144015028	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.04346	-118.25305	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW MIXED USED BUILDING. SCOPE INCLUDES 1753 FA DEVICES, AND 8 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53416	14041-20000-10926	10844 W BLIX ST	91602	2	168B173   609	2421023001	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			04/25/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.15658	-118.3674	New 2-story apartment building (10 units) and one level of parking garage.  600A 120/240V 3ph-4w service.  Applicant to submit Title 24, floor and site plans, and panel schedules.  Fees to be reverified.  Conduit only permit issued.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53417	16041-10001-34648	10250 W SANTA MONICA BLVD #1570	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM			PC Approved	01/05/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"*Changes to approved set: Change of use from restroom to storage. Others remained the same, changes noted under delta-2.  Permit shall be issued under master plan 16041-10000-34648.<<Full Plan check for a first time tenant space at westfield mall ""Zadig"". Adding a new panel and a tranformer under existing service. New lighting and power. Total sqft = 2243*New load 46A to MS-ELA42Fire alarm system and low voltage are not subject to this plan check.>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53418	14041-10000-11671	5633 N RIVERTON AVE	91601	2	174B177   438	2415008016	R2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Expired	06/13/2016 12:00:00 AM	ADDRESS	34.1731	-118.36606	PV1, INSTALL 5.0 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER: POWER-ONE # AURORA PVI-4.2-OUTD-S-US-Z-A(20) MODULES: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53419	18041-20001-39858	11428 W SHERMAN WAY	91605	2	183B169   683	2320001022	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.20103	-118.37983	Revision to approved set of plans.  (1) transformer's % impedance changed to as-built condition, ground detectors added on secondary side of all ungrounded separately derived systems. (((PLAN CHECK FOR COSTCO DUE TO CHANGE OF DESIGN FROM ORIGINAL SUBMITTAL (18041-10000-24350). NEW EQUIPMENT AND CKTS ALSO ADDED. ALL CKTS AND EQUIPMENT FEE WILL BE UNDER INSPECTION FEE ONLY. BUILDING PERMIT: 18016-10000-20836)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53420	16041-10001-22238	507 S MAPLE AVE	90013	14	127-5A213  55	5148018027	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.0453	-118.24692	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. CLOUDED. CHANGES INCLUDE REVISION TO COMMON AREA LIGHTING, NEW T24 PROVIDED. UPDATED NOTES AND REVISED A COUPLE OF CIRCUITS. ADDED HEATERS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53421	17041-10001-22471	9454 N GIERSON AVE	91311	12	198B101    50	2727020020	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.24241	-118.61131	Expedite fees only       Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 12.395 kWac.  AC module system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53422	19041-20000-23367	5800 W SUNSET BLVD BLDG 11-#201	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.09728	-118.31693	ENERGY ONLY PLAN CHECK. T24 LIGHTS AND OUTLETS ONLY. EXISTING HIGH RISE COMMERCIAL OFFICE 2ND FLOOR. TOTAL SQUARE FOOTAGE = 4,910 SFB#19016-10000-12432	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53423	16041-20000-31887	14861 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29534	-118.45525	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53424	11041-20000-21533	970 W 190TH ST Ste 550	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	33.85812	-118.29302	T.I.  Remodel of the light fixtures in Suite # 550.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53425	18041-20001-39536	8550 W WENTWORTH ST	91040	7	207B189   169	2555003002	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.26677	-118.31971	Revisions to approved plans.  Relocation of equipment.  $0 pan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((Plan check for PV roof mounted with Energy storage system, PV system size: 4.575kW with 15 PV Modules and 1 inverter(3.8kw) and 1 Tesla Battery 2.0 13.5kWh)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53426	15041-20000-30225	2117 N PRINCETON AVE	90026	13	144A211   129	5420035013	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.08963	-118.24918	PV1 system,Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3kWac. Ungrounded system. Using (1) 400W power optimizer per pv module.(6) 320W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53427	18041-30000-05370	19509-19517 W ASTOR PL	91324	12	198B117   253	2761035014	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			02/13/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.23731	-118.55834	Plan check for power only New 5 units townhouse building with 600A Service. B#17010-30000-04712	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53428	16041-10000-35934	6529 S BRYNHURST AVE	90043	8	105B185  1343	4006020015	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	33.97971	-118.33395	PV1, ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS. 15 SOLAR PANELS AND (15) ENPHASE M215. TOTAL SYSTEM SIZE 3.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53429	11041-20000-05547	6301 N OWENSMOUTH AVE 5TH FL	91367	3	177B105   123	2146029016	WC	Central, South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	06/21/2011 12:00:00 AM	ADDRESS	34.18467	-118.60176	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT 5TH FL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53430	18041-30000-35052	8330 N RESEDA BLVD	91324	12	192B125   576	2786022026	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.22174	-118.53587	Plan check for a fire alarm system for a commercial building. Fire alarm consists of (1) FACP and (146) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53431	18041-20000-38072	4960 N SEPULVEDA BLVD	91403	4	168B145    67	2263017038	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.16069	-118.46592	Plan check for new fire alarm system, for apartment building. Total fire alarm devices: 92 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53432	15041-10000-41436	420 N CENTRE ST	90731	15	018B201   331	7449008023	R2-1XL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Expired	02/28/2018 12:00:00 AM	ADDRESS	33.74634	-118.28337	PV1, INSTALL 3.0 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(9) MODULES: KYOCERA KU2656ZPA(1) INVERTER:SOLAREDGE SE3000A-US-ZB	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53433	16041-20003-08861	15303 W VENTURA BLVD SPACE P10	91403	4	168B145   821	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/26/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	6.6.2017 - Plans lost. Rechecking electrical plan for Title 24 only.=======Original approved plans lost at job site - recheck of electrical drawings - T-24 Part 6 plan check only.  (((T-24, PC for energy only. TI on (E) Restaurant inside the Sherman Oaks Galleria - SPACE P-10. Total area: 2,691 sq. ft)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53434	19041-10000-46357	227 S WOODBURN DR	90049	11	135B145   328	4365004013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.0679	-118.46703	[EPLAN] PLAN CHECK FOR 2 TELSA POWERWALL'S, CONNECTED TO AN EXISTING 400A MAIN SERVICE PANEL. EXISTING PV1 SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53435	18041-10000-06618	808 N LILLIAN WAY	90038	13	141B185   199	5533030010	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.08566	-118.32757	Plan check for a fire alarm sprinkller monitoring system. Scope includes new fire alarm panel and (10) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53436	11041-20000-18339	6500 W WILSHIRE BLVD 19th floor	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TI WORK ON 19TH FLOOR.  Only units were counted based on the contractor's agent's  statement of extent of workm, indicated no new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53437	19041-10000-51786	3625 W STOCKER ST	90008	8	114B185   529	5032002038	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM			PC Info Complete	12/16/2019 12:00:00 AM	ADDRESS	34.00827	-118.33612	PLAN CHECK FOR TITLE 24. SCOPE OF WORK INCLUDES ALTERATIONS TO LIGHTING FIXTURES AND NEW CIRCUITS. TOTAL AFFECTED AREA: 333 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53438	15041-30000-36049	2029 S CENTURY PARK EAST Suite 2950	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	Title 24 plan check only.  Total area = 5,230 sq. ft.    T.I. to existing commercial highrise office space.  Lew lighting and receptacles to office and show room area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53439	15041-20000-34965	515 S FIGUEROA ST 18th Fl.	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI on the 18th floor corridor of a high rise commercial build. Replacing all fixtures to new lighting fixtures.Total area: 1,493 sq.ft. PC for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53440	10041-20000-12677	12210 W VENICE BLVD	90066	11	114B157  1487	4235023002	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.00456	-118.4314	Plan check T-24 Energy for general/emergency lighting for market TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53441	17041-20000-41029	1888 CENTURY PARK EAST 1400	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	PIN	34.06160176	-118.41389445	Tenant improvement in (E) commercial highrise office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53442	17041-20000-10662	7017 N DEVERON RIDGE ROAD	91307	12	183B089   358	2028044008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.19759	-118.64784	pv1install roof mounted pv system sized 5.2kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53443	17041-20000-29543	6600 N TOPANGA CANYON BLVD ste 2018	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53444	13041-10000-26382	1924 N MYRA AVE	90027	4	150B201   913	5591018024	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.10616	-118.28022	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 2.5 KW DC ON non-standard PLAN IN A SINGLE-STORY HOME. power optimizers IS UTILIZED.(10) MODULES: TRINASOLAR TSM-250PA05.18(1) INVERTER: FRONIUS #IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53445	16041-20000-07189	7438 N JAMIESON AVE	91335	3	186B129   693	2120030007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.20593	-118.52173	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (11) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53446	17041-20003-31690	3019 E ASBURY ST	90065	1	147A217    68	5454031025	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.09865	-118.23001	Change of conductor routing - inverter output circuit routed in same raceway as energy storage system output circuit.  $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.(((07-31-2018 Changes to an approved set of plan, changes include addtion of disconnect. Plan check only)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53447	15041-20000-03535	12777 W JEFFERSON BLVD 2ND  FLOOR	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.9778	-118.41768	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR OFFICES. TWO STORY BUILDING.  SECOND FLOOR ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53448	18041-20002-01292	641 N CRANE BLVD	90065	1	150A223   111	5466006017	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM			PC Approved	03/02/2018 12:00:00 AM	ADDRESS	34.10672	-118.20996	03/02/2018 Changes to an approved set of plans. Location of PV equipment has changed. PV system size has remained the same. *****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (1) load center, and (25) modules. PV system is interconnecting to a center-fed MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53449	19041-20000-42428	13261 W SEVILLANA WAY	91342	7	225B157  1048	2510026013	(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	ADDRESS	34.31555	-118.42235	Plan check for PV roof mounted system, PV System size: 1.68KW with 7 PV Modules and 7 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53450	16041-10000-37327	12169 N STEWARTON DR	91326	12	219B121   377	2820017025	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.29327	-118.54446	PV1 roof mounted solar system to a single family home. Installing 16 microinverters rated at 345 watts each for a total size of 5.52 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53451	16041-20000-32346	12640 W SATICOY ST	91605	2	186B161   454	2305025010	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.2067	-118.40901	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53452	17041-10000-10897	4436 S LONG BEACH AVE EAST	90058	9	112-5A213 196	5106007001	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.0028	-118.24293	Plan check for Title 24.   T.I. to restaurant including new lighting.  Total area = 2,393 sq. ft.Building permit #16016-10000-22945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53453	15041-10000-00081	4645 N VAN NUYS BLVD #201	91403	4	168A151    62	2265012015	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.15597	-118.44889	Plan check for Title 24 only. Project is an existing commercial space. Total lighting area = 1,491 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53454	13041-10000-08845	621 W 152ND ST	90247	15	072B201    75	6120001017	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	33.89472	-118.28668	ADDING NEW FEEDERS TO EXISTING SYSTEM FOR CALIFORNIA WASTE MANAGEMENT. METHANE ZONE. DOING UNDERGROUND AND SURFACE LEVEL WORK HOWEVER UNDERGROUND CONDUIT IS EXISTING ONLY ADDING NEW WIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53455	19041-20000-21554	17813 W WELBY WAY	91335	3	180B129    79	2122017010	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.1931	-118.52116	pv1install roof mounted pv system sized 3.8KW aC interconected with msp.(1) LG battery rated 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53456	15041-20000-23266	15930 W RINALDI ST	91344	12	213B141   143	2666006002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Expired	08/16/2017 12:00:00 AM	ADDRESS	34.27886	-118.47926	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53457	13041-20000-32793	15233 W VENTURA BLVD SUITE 1212	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.1538	-118.46502	PC FOR  T24 ENERGY ONLY. EXISTING OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53458	17041-20000-39882	10727 W WILSHIRE BLVD 1-109	90024	5	132B153   123	4360033***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.06081	-118.43692	11/3/2017change of contractor.Plan check for power only.  Installation of new distribution board for installation of new car chargers in existing highrise residential building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53459	13041-10000-17381	11776 W IDAHO AVE	90025	11	126B149  1247	4262013001	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			07/01/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.04143	-118.45674	Plan Check for fire alarm system in an apartment. 4 stories. 39 devices and 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53460	14041-10000-05603	5157 S CRENSHAW BLVD	90043	8	108B185   116	5013018006	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Closed	10/26/2016 12:00:00 AM	ADDRESS	33.99449	-118.33114	PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY CHARTERED SCHOOL. 2 SERVICES.FIRE ALARM PLANS TO BE SUBMITTED SEPERATELY. (variance was filed)BUILDING P# 14010-10000-00540 : NEW 3 STORY SCHOOL (74' WIDE X 340' LONG) CONSTRUCTION TYPE II-B  FULLY SPRINKLERED, TOTAL SQUARE FOOTAGE 54,567 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53461	17041-20000-10593	7835 S GLORIA AVE	91406	6	189B141   290	2206009901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Info Complete	07/02/2018 12:00:00 AM	ADDRESS	34.2115	-118.47956	Change of use from commercial warehouse space to office.  Plan check for power and energy - newly connected load in excess of 400A.BUILDING PERMIT : 17016 20000 07030	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53462	18041-10000-04266	4552 W COLORADO BLVD	90039	13	162B205   102	5593018008	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.1413	-118.27231	PC for T24 only for replacement of metal halide fixtures with new LED fixtures in indoor and outdoor areas. Total area 31800sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53463	13041-10000-07293	18770 W FAIRFIELD ROAD	91326	12	207B121   680	2728031034	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	34.26173	-118.54196	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. PV1. 10.5KW. USING TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. TOTAL OF 43 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53464	10041-20000-07848	11150 W SANTA MONICA BLVD 400	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	ENERGYB PLAN CHECK # 400 RELOCATE  FIXTURES  ONLY EMERGENCY LIGHTING EXISTING TO REMAIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53465	13041-10001-30240	633 S MISSION ROAD	90023	14	124-5A219   3	5171015001	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	PIN	34.0373651	-118.22637397	PV2.  Install 287 kW DC roof-mounted solar array, interconnect with existing 1200A switch board.  1157 modules: Orion Series ECO250A-156P-60.  Commercial inverter: Solectria SGI 250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53466	11041-10000-11632	1545 W WILSHIRE BLVD 4th fl	90017	1	132A205   208	5142027025	CW	Central	Westlake			2091.02	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.05543	-118.26977	new panelboards and 60KVA UPS and circuits in renovating offices on the 4th flplan check is for title24 and 1 ea emergency ckt ; permit fee is in Inspection fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53467	15041-10000-23647	1201 N MARIPOSA AVE	90029	13	144B197   303	5540002020	R4-1	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Apartment			08/13/2015 12:00:00 AM			Reviewed by Supervisor	09/23/2015 12:00:00 AM	ADDRESS	34.09339	-118.29965	NEW THREE STORY 33 UNIT APARTMENT BUILDING WITH TYPICAL UNITS.   PLAN CHECK FOR POWER AND ENERGY.FIRE VARIANCE TO BE FILED AT A LATER TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53468	15041-20000-28732	11929 W COURTLEIGH DR 1-22	90066	11	111B157  1103	4233018022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	33.99687	-118.41943	PV2 COMMERCIAL ROOFTOP. TOTAL SIZE 15KW AC USING 54 MODULES. INTERCONNECT TO HOUSE PANEL OF EXISTING APARTMENT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53469	18041-30000-30660	9301 N TAMPA AVE #184	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 energy only, Tenant Improvement for existing retail space within Northridge Fashion Center. Space 184 Total area: 3132 sq ftB# 18016-30000-02252	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53470	15041-20000-32741	4521 N AIDA PL	91364	3	165B097    40	2074037029	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Expired	10/31/2017 12:00:00 AM	ADDRESS	34.1521	-118.62522	PV1. Install roof mounted PV system sized 6.0 kW. Interconnected with main service panel.(24) Kyocera KU 265 Modules(1) ABB PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53471	15041-10000-42973	1925 S CENTURY PARK EAST 14th floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Issued	12/31/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	Tenant Improvement , PC for energy only to a commercial building (offices). Adding new lighting and power to the 14 floor common area. Sq ft = 1487	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53472	18041-10001-19969	11580 W SUNSET BLVD	90049	11	135B145   278	4365004018	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.06826	-118.46983	>> expedited fee per applicant <<New PV1 rooftop solar, 11.05 kW DC/ 10 kW AC system. (34) modules, (1) inverter.**Note: New service at 225 A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53473	12041-10000-00072	210 N MOTT ST	90033	14	127-5A225 248	5180016010	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM			PC Approved	02/06/2012 12:00:00 AM	ADDRESS	34.04308	-118.20525	Change of lights to an existing retail space.  PLAN CHECK ONLY for Energy only with No emergency lighting.  Permit has already been pulled for the project.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53474	10041-10000-03924	13061 W BLUFF CREEK DR	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/25/2010 12:00:00 AM	ADDRESS	33.97047	-118.42362	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53475	19041-10000-06943	13630 W VICTORY BLVD	91401	2	180B157   958	2330012022	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.1865	-118.43001	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53476	17041-20001-46494	10625 W TABOR ST	90034	5	120B161   930	4314011014	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			12/28/2017 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.02357	-118.41014	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on apartment building.9kW ungrounded system. (31) 360W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53477	14041-20001-00638	8531 N RUBIO AVE	91343	12	192B137   104	2689016004	RA-1	North Valley		North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.22584	-118.49683	EXPEDITE FEES ONLY     <<<<New 10.5kw rooftop PV system for an existing single family dwelling.  System is Ungrounded.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53478	16041-20001-04044	3665 S HUGHES AVE	90034	5	120B165   600	4313008036	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.02575	-118.4009	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR INSTALLATION. CENTRAL INVERTER SYSTEM. SYSTEM SIZE: 55 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53479	18041-10000-30098	1999 S AVENUE OF THE STARS 24TH	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PC FOR T-24 ENERGY ONLY FOR OFFICE TI FOR MORGAN STANELY ON THE 24RD FLOOR. TOTAL AFFECTED AREA 5489 SQ.FT SCOPE INCLUDES EQUIPMENT, CIRCUITS AND LIGHTS. B#18016-10000-25346	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53480	17041-20000-28509	1026 W 34TH ST Suite 127	90731	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.02414	-118.28985	Plan check for Title 24 only. Project site is an existing exercise room. Project scope is a tenant improvement. Total lighting area = 1,852 sq. ft.Note: Building application has been generated under 17016-10000-20496	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53481	16041-10000-37038	2851 W PICO BLVD	90006	10	129B193  1225	5080035014	[Q]C2-2	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.04737	-118.30181	PC for T24 energy only for outdoor lighting. Provide new light to replace existing in same location. More efficient luminaires.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53482	12041-10000-05956	221 S GRAND AVE	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.05419	-118.2505	NEW FIRE ALARM SYSTEM FOR BROAD MUSEUM PARKING STRUCTURE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53483	14041-10000-14332	1307 S OCEAN FRONT WALK	90291	11	108A143   412	4226006003	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	33.98828	-118.47474	Change of use to take out tenant imporovement of existing two story building.Total area = 1713 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53484	19041-10000-31821	1510 S LA BREA AVE	90019	10	129B181  1180	5070019037	C2-1-O	Central	Wilshire			2172.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	07/25/2020 12:00:00 AM	ADDRESS	34.04643	-118.34501	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53485	14041-20000-12568	11755 W WILSHIRE BLVD suite 1700	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	PIN	34.04869377	-118.46238681	PLAN CHECK FOR ENERGY ONLYHigh rise commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53486	17041-20001-08283	4201 N ALEMAN DR	91356	3	165B113   192	2178008024	A1-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM			PC Approved	03/31/2017 12:00:00 AM	ADDRESS	34.14602	-118.56512	expedite.pv1install roof mounted pv system sized 12kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53487	16041-20000-27079	17780 W RIDGEWAY ROAD	91344	12	213B129    92	2601039028	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.28287	-118.52091	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (44) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53488	16041-10001-14128	5343 W IMPERIAL HWY #900	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	33.93128	-118.37337	10/20/16Changes to an approved set of plans. All changes are clouded under delta 2. Changes on the single line diagram to reflect what is on the field. Note: permit is paid under PCIS16041-10000-14128((((((T-24, PC FOR ENERGY ONLY. TI TO A TWO-STORY EXISTING COMMERCIAL BUILDING(OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 9010 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53489	15041-20000-08331	17823 W CHATSWORTH ST	91344	12	207B129   365	2712030017	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.26513	-118.52237	Plan check for power and  energy T.I. for restauruant and new service 400A. Total area: 3252 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53490	17041-10001-23569	1316 N GLENDALE BLVD	90026	13	139-5A209  16	5419031015	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.0786	-118.25998	PC FOR CHANGES OF USE FROM WAREHOUSE TO GYM. A3 OCCUPANCY LOAD GREATER THAN 100. FULL PC FOR POWER AND ENERGY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53491	18041-20000-11079	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015037	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.09649	-118.33888	Tenant improvement for ground floor cafe tenant space.   Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53492	11041-10000-22285	1134 N VERMONT AVE	90029	13	144B197   506	5542029039	C2-1D, C2-2, P-1	Central	Hollywood	East Hollywood		1913.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	34.09188	-118.29154	TENANT IMPROVEMENT AT THE WABA GRILLPLAN CHK IS FOR TITLE 24. PERMIT FOR NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53493	18041-20001-41886	13254 W ARMINTA ST	91605	2	189B157  1036	2303004021	RE9-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.21324	-118.42245	Expedite per applicant rquestPlan check for PV roof mounted system, system size: 14.4kW DC, 12.24KW AC with 40 AC Modules connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53494	18041-20000-48746	14930 W DRELL ST pv1	91342	7	225B149   137	2502008034	RA-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.3156	-118.45773	pv1install roof mounted pv system sized 5.985KW with 19 PV Modules, 1 inverter(7.6KW) and 27KWH Energy Storage System interconnected with msp.(2) tesla 13.5KWh batteriesPermit Fees $94.67 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53495	13041-10000-00996	936 E PICO BLVD A,B,1/2	90021	14	123A211   255	5132018013	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.03058	-118.24946	FULL PC POWER AND ENERGY PLAN CHECK. NEW 600 A SERVICE. not methane. the 3 spaces will share a common domed roof made of woodCHANGE OF USE FROM WAREHOUSE TO RETAIL/WHOLESALE. TI TO EXISTING BLDG. CHANGE SPACE TO 3 separate RETAIL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53496	01041-10001-01661	851 S GRAND AVE	90017	14	127-5A209  54	5144020012	[Q]R5-4D	Central	Central City			2077.10	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM			PC Approved	07/30/2012 12:00:00 AM	ADDRESS	34.04476	-118.25923	Plan review for as-built set of plansRooms and corridor remodeling , 4th to 9th floor, EMBASSY HOTEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53497	16041-10000-28519	10161 N WHITE OAK AVE	91325	12	204B129   262	2734004022	RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.25577	-118.52003	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 12 kWac.  Two SMA SB6000TL inverters with 37 modules total.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53498	15041-20002-00885	21434 W OSBORNE ST	91304	3	195B105    66	2779047006	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	34.2335	-118.59873	PC FOR T24 ENERGY ONLY. RECONNECTION OF 400A SERVICE WILL REQUIRE SEPARATE PLANS AND PERMIT. permit for this scope of work already issued under master	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53499	16041-20000-26843	6901-6907 N HAYVENHURST AVE	91406	6	183B137   350	2225002002	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM			PC Info Complete	10/04/2016 12:00:00 AM	ADDRESS	34.19574	-118.49262	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD<400 AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHTING ONLY. TOTAL SQUARE FOOTAGE 12553.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53500	11041-10000-21067	950 N HIGHLAND AVE	90038	4	144B185   987	5532013030	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.08857	-118.33841	"T.I. to change retail to ""Pooch Hotel"".  Plan check is for POWER and Energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53501	14041-20001-11523	10476 N VANALDEN AVE	91326	12	207B121   706	2728015002	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.26144	-118.54922	((expedite fees)))pv1 single family dwelling. total system size 10kw ac using transformerless ivnerter. nonstandard plan. using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53502	14041-10000-20663	1625 E 4TH ST	90033	14	127-5A219 257	5172024011	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.04311	-118.22186	"plan check for power and energy (2008 standards). Dentist office and Non oshpd per applicant. Partial permit fees covered under 14041-10-15031. AC unit to be charged under this application. BLDG#14016.10.04870: CHANGE OF USE FROM A SFD TO A MEDICAL OFFICE 23' 8""  x   25'1""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53503	16041-10000-16196	827 E 3RD ST	90012	14	129A215   261	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.04599	-118.23556	TI AND INTERIOR RETAIL ADDITION ON  FIRST AND 2ND FLOOR .  CHANGE OF USE PORTION OF RETAIL TO RESTAURANT, TATOO SHOP. PARTIONAL TAILOR METHOD( 1792 SQ FT FOR RETAIL SPACES) AND 2504 SQ FT FOR AREA CATEGORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53504	11041-10000-14179	8417 W 3RD ST	90048	5	138B173   737	5511014017	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM	09/16/2011 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.07321	-118.37368	T.I.  Office space being converted to beauty salon.  This is a single story building.  Change of use.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53505	13041-10000-22274	23625 W STRATHERN ST	91304	12	189B093   259	2020018050	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.21519	-118.64164	PV1.  INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53506	18041-20000-18838	21600 W OXNARD ST	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM			Reviewed by Supervisor	05/31/2018 12:00:00 AM	ADDRESS	34.179	-118.6002	Installation of (20) EV charging stations in (E) commercial parking garage supplied by new 150 kVA transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53507	15041-20000-34335	5762 W MORLEY ST	90045	11	093B169    54	4125011013	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			10/15/2015 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	33.95362	-118.38262	Plan check for New appartment building 31 units. 800A Service.Note: additional 20 circuit fees has been added  to the submittal fees  due to applicat has pre-cut check; upon pulling permit 20 circuit shall be remove..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53508	19041-20000-10404	16909 W ARMSTEAD ST	91344	12	213B133   224	2610009004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.28259	-118.50024	pv1install roof mounted pv system sized 7.6KW AC with battery 5KW interconnected with msp. Fees $65.01 due to California Senate Bill 1212 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53509	12041-20001-26278	18616 W INGOMAR ST	91335	3	189B121   575	2103025047	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	34.21184	-118.53892	Modification to previously approved set of plans.  New main service panel with 225 Amp bus.  Main breaker to remain the same and no new loads added.     <<<<<New 11.0kw rooftop mounted photovoltaic system for an existing single family residence.  Plan check is Only for the PV system and NOT for de-rating the main breaker.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53510	14041-10000-00137	1001 S TOWNE AVE #110	90021	14	124-5A211 269	5132010049	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.03417	-118.24984	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 364 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53511	14041-20000-09708	10017 N WISH AVE	91325	12	204B133   578	2694007026	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.25289	-118.50807	Roof mounted PV system with transformerless inverter.  System size 6KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53512	11041-10000-06727	7861 W MELROSE AVE	90046	5	141B177   517	5527011020	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Expired	04/29/2013 12:00:00 AM	ADDRESS	34.08395	-118.36093	TENANT IMPROVEMENT IN A MINI MART PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53513	17041-20000-42261	10205 N TELFAIR AVE	91331	7	204B161   330	2623011001	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.25561	-118.41738	PV1. Install roof mounted PV system sized 10.4 kW intetrconnected with MSP.$11.83 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53514	16041-20000-16553	1663 S LA CIENEGA BLVD	90035	5	129B173  1220	4303028034	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.04727	-118.37639	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR RESTAURANT. 1545 SQFT.NOTE: PERMIT PAID UNDER PCIS#16041-10000-05885	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53515	11041-20000-19201	4040 N BECK AVE	91604	2	162B169   391	2368023058	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	03/05/2012 12:00:00 AM	ADDRESS	34.14113	-118.38319	Plan check roof mounted photovoltaic system 15.12KW single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53516	18041-10000-46878	225 N VERMONT AVE 139A	90004	13	138B197   512	5518033032	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2112.02	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	34.07529	-118.29188	PC FOR TENANT IMPROVEMENT TO FIRST TIME TENANT( SALON) RETAIL SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53517	15041-10000-20589	1605 N CHEROKEE AVE 1-66	90028	13	148-5A185 268	5547014***	PF-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.09994	-118.3353	temp power for construction site 800 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53518	17041-20000-43099	7341 W VALMONT ST	91042	7	204B197  1066	2558022008	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	07/16/2021 12:00:00 AM	ADDRESS	34.25243	-118.29238	Plan check for power and energy. Project site is a new 3-story, 5-unit apartment building. Work includes a 600-amp service and a total lighting area of 14,410 sq. ft.Note: Building application has been generated under 16010-10000-04776	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53519	18041-10000-18579	1532 N HIGHLAND AVE	90028	13	147A185    22	5547020011	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.099	-118.33847	Plan check for a fire alarm system located in a commercial building. Scope includes (1) fire alarm panel, (1) control panel, and (98) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53520	11041-10000-23502	725 W 7TH ST	90017	9	129A209   265	5144029***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	05/15/2012 12:00:00 AM	ADDRESS	34.04858	-118.25834	New circuits and panels for restaraunt.  Plan check for POWER and ENERGY per applicants request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53521	16041-10000-34553	689 S MESQUIT ST	90021	14	124-5A217 235	5164018009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.03501	-118.2292	PC FOR ENERGY ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. INDOOR LIGHTING AREA 5800 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53522	18041-20000-26660	7439 N VAN NUYS BLVD	91405	6	186B149   389	2218004016	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Issued	02/05/2019 12:00:00 AM	ADDRESS	34.20587	-118.44898	"Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 1,000-amps.""Comply with Department Order effective date01/24/2019. If additional assistance is needed please call SeniorInspector MICHAEL SCHULZINGER at (213)252-3962.  CEIS Case Numberis 842997."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53523	13041-10000-30824	10326 N ORO VISTA AVE	91040	7	204B189   442	2560013009	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.2569	-118.31562	PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 2.75 KW.(11) TRINA SOLAR # TSM-250PA05.18(11) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53524	10041-10000-11868	310 S CENTRE ST	90731	15	018B201   821	7455019919	C2-2-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	03/22/2011 12:00:00 AM	ADDRESS	33.74099	-118.28332	New fire alarm system. Plan check for power. (addition to the new fire alarm system # 10041-10000-11864)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53525	11041-10000-27647	175 S FAIRFAX AVE	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	Plan check for new 110.7KW roof mounted photovoltaic system for Trader Joe's	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53526	17041-10000-20723	593 W 6TH ST	90731	15	015B197   378	7451037025	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	33.73865	-118.28983	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53527	13041-20001-25818	11555 W NATIONAL BLVD	90064	11	120B153   745	4258015033	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.02401	-118.43641	((EXPEDITE FEES))PV2 (Church) NEGATIVELY GROUNDED SYSTEM. 8.1KW SYSTEM. 4 STRINGS AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53528	13041-10000-34900	7450 WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Closed	08/07/2014 12:00:00 AM	ADDRESS	33.94114	-118.42608	pc for energy only .  permit to be pulled at EPC counter. CAnOPY WITH LIGHTS FOR BAGGAGE HANDLING AREA. 277V 10 lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53529	18041-10000-27049	818 W 7TH ST SUITE 700	90017	14	129A209    74	5144010018	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.04895	-118.25943	PLAN CHECK FOR POWER AND ENERGY FOR TENANT IMPROVEMENT OF 12,027 S.F. OFFICE SPACE. TOTAL CONNECTED AND RELOCATED LOAD IS APPROX 400A IN A HIGH RISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53530	17041-20001-38045	1015 S ORANGE GROVE AVE	90019	10	132B177   718	5086001053	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.0575	-118.36311	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on commercial building.Total system size: 20kW ungrounded.(2) 10kW SolarEdge inverters.(91) 300W pv modules.(91) 300W power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53531	19041-10000-12605	13595 W HERRON ST	91342	7	225B157   548	2510017023	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Issued	04/08/2019 12:00:00 AM	ADDRESS	34.31273	-118.42952	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 22 MODULES (CANADIAN SOLAR 305W), 22 OPTIMIZERS (SE P320) AND 1 CENTRAL INVERTER (SE6000H-US). SYSTEM SIZE IS 6.71KWdc AND 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53532	12041-10000-18573	445 S FIGUEROA ST	90071	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.00, 2077.10	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	Change to lighting, loads, and receptacles to 20th floor of an existing high-rise office building.  Per the engineer, the electrical load is 129Amps.  Plan check is only for T-24 Energy, with Emergency lighting.  Full Plan Check may required if there is any other work in the building with a combined load over 400Amps.  Permit Fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53533	10041-20000-11852	3415 S SEPULVEDA BLVD 10TH FL	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	08/27/2010 12:00:00 AM	ADDRESS	34.02055	-118.42347	"PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING ON 10TH FLOOR. ALL CIRCUITS ARE EXISTING. COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53534	12041-10000-15816	444 S FLOWER ST	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.05189	-118.25546	REMODEL EXISTING OFFICE SPACES ON THE 35TH FLPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53535	17041-10000-06039	13274 W FIJI WAY #375	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	33.97902	-118.43558	Plan check for Title 24 only in existing space T.I. office space. total area: 1,051 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53536	15041-10002-39684	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	Changes to approved set of plans. Scope includes adding new fixture and  ckts on the floor plan.  All changes under delta_6 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53537	15041-10000-35051	814 N SAN FERNANDO ROAD	90065	1	144A219    36	5453006048	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.09066	-118.22723	T-24, TO AN (E) COMMERCIAL, WORK AREA, BUILDING. REMOVED HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53538	18041-10000-45019	22216 W MAYALL ST	91311	12	204B101   445	2745011041	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.25385	-118.61117	PC FOR NEW ROOFTOP PV SYSTEM FOR (E) SFD. 5KW AC SYSTEM, (16) SOLAR MODULES, (1) 5KW SE5000H-US INVERTER, (16) P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53539	18041-20001-24497	5050 W PICO BLVD	90019	10	129B181  1004	5070017003	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Apartment			11/14/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	09/20/2021 12:00:00 AM	ADDRESS	34.04771	-118.34793	Revisions to approved plans.  Increased service and distribution amp ratings to accommodate change from gas to electric appliances in dwelling units and revised HVAC configuration.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53540	18041-20000-17963	20627 W CHESTNUT CIR (#275)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.29325	-118.58341	Plan check for a PV1 roof-mounted PV system. System size is 2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53541	11041-10001-15782	680 S SANTA FE AVE	90021	14	124-5A217 169	5164018004	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	ADDRESS	34.03555	-118.23008	"As-built set of drawings. Removal of panel ""PC"" and four air conditioners.T.I.  One story warehouse was damaged during a fire.  Work to be done is to install a 600 amp service, 2 panels, and to re-wire the entire area including lighting.  Plan check is for energy and power"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53542	17041-10000-38108	4365 S GLENCOE AVE	90292	11	105B153    82	4212004025	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	33.98574	-118.43849	Alterations in a Pavilion  grocery store- one new panel, new circuits and lighting changes and addition	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53543	19041-10000-44663	711 N MAIN ST 2ND FL	90012	1	133-5A215 338	5408013033	C2-2	Central				2071.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	03/15/2021 12:00:00 AM		Issued	03/15/2021 12:00:00 AM	PIN	34.05848271	-118.23802112	CONVERTING 2ND FLOOR OF COMMERCIAL BUILDING TO 26 HOTEL UNITSNEW PANELBOARDS AND CIRCUITS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53544	15041-20000-15799	11550 N INDIAN HILLS ROAD #160	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.27998	-118.45874	"Plan check for power only~ Providence Holly Cross Surgery Center (Out Patient Center). Replace A/C units(Condensing unit and Fan coil units). Lighting replacement. ""I"" occupancy according to the applicant, which is exempt from title-24 lighting compliance."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53545	19041-10000-48395	9850 S LAUREL ST	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	33.94793	-118.23082	"NEW FIRE ALARM SYSTEM IN A NEW RETAIL STORE ""SMART & FINAL""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53546	16041-10000-41249	12520 N ARISTO PL	91344	12	219B129   304	2608011035	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.29786	-118.51505	PV1 roof mounted solar system installation. Installing new central inverter rated at 3.8 KWac. and 16 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53547	12041-10000-17642	879 W 190TH ST #935	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	08/10/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	33.85951	-118.28963	Change to lighting in an existing high-rise building.  No new load, existing circuits only and no change to emergency lighting.  PLAN CHECK ONLY for Energy.  Emergency lighting is NOT PART of this Plan Check.  Permit Fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53548	10041-10000-14224	745 W ADAMS BLVD	90007	1	123A203   178	5124025001	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	34.02985	-118.27941	CHANGE OF USE FROM APARTMENT BUILDING TO OFFICE BUILDING.  NEW 600 AMP SERVICE, PANELS, CIRCUITS, LOADS & LIGHTING. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53549	14041-10000-30293	469 N EL MEDIO AVE	90272	11	126B125   531	4413009002	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.04168	-118.53506	Installation of new roof mounted solar PV array.  31 modules, (1) load center, and 2 inverters (4 kW and 3 kW), connected to an existing 400A  panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53550	18041-10000-00539	15355 W MULHOLLAND DR	90077	4	159B145   557	2279027004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.12978	-118.4678	PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A DISTRUBTION PANEL (200A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53551	18041-30000-26577	6922 W HOLLYWOOD BLVD 4TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLAN CHECK FOR T24 ONLY, RESTROOM RENOVATION ON THE 4TH FLOOR. APPROX 303 SF TOTAL. PROVIDING NEW LIGHTING AND RECEPTACLES, CIRCUITS ARE FED FROM EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53552	18041-10000-03427	1333 W 190TH ST	90248	15	060B197   575	7351001022	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	33.85855	-118.30048	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53553	17041-10000-08619	13153 W FOOTHILL BLVD	91342	7	219B157   187	2513027052	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.29895	-118.42071	PC for energy only, outdoor. Removing HID fixtures and replacing them with new LED ones. Area: 26,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53554	17041-20001-29488	1895 N RISING GLEN ROAD	90069	4	150B169  1611	5562019018	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2017 12:00:00 AM			PC Approved	09/11/2017 12:00:00 AM	ADDRESS	34.10513	-118.3852	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (2) inverters, (60) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53555	16041-20000-41558	6657 N LAUREL CANYON BLVD	91606	1	180B165   234	2322004070	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.19192	-118.39674	PLAN CHECK FOR ENERGY OUTDOORS (PARKING LOT) ONLY.  TOTAL QUARE FOOTAGE 59981.REPLACEMENT WITH NEW LED LIGHT FIXTURES WIRING TO REMAIN.  NO NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53556	18041-10000-06095	19191 S VERMONT AVE #100	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR TITLE 24 ENERGY ONLY. TENANT IMPROVEMENT TO (E) OFFICE SPACE (HIGHRISE) SCOPE INCLUDES NEW AND RELOCATED FIXTURES TOTAL AFFECTED AREA 1160 SQ FT BUILDING#18016-20000-03482	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53557	13041-10000-08315	20050 S VERMONT AVE	90502	15	057B197   154	7351033062	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/01/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	33.84838	-118.29024	RENOVATION OF EXISTING EDUCATIONAL CENTER. NEW TENANT FOR CHURCH USE, PLACE OF ASSEMBLY. PC FOR ENERGY COMPLIANCE AND EMERGENCY LIGHTING. LOW ADDITIONAL LOADS. MOST EXISTING ELECTRICAL WORK..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53558	19041-20000-28761	555 W 5TH ST 3rd flr	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/02/2020 12:00:00 AM	ADDRESS	34.05016	-118.25369	Power and lighting for TI to (E) commercial highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53559	13041-20000-20335	146 S CITRUS AVE	90036	5	138B185   365	5513014010	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.07222	-118.33954	PV1 TRANSFORMERLES SYSTEM. TOTAL SYSTEM SIZE 4.41 KW. 18 MODULES AND 1 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53560	16041-10000-30090	8550 N BALBOA BLVD #232	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.22649	-118.5024	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1875 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53561	15041-20000-28447	8 S BEVERLY PARK	90210	5	150B157   105	4386028019	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.10889	-118.42209	PLANCHECK FOR  A SINGLE FAMILY HOME. 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53562	19041-10000-43402	2717 W 3RD ST	90057	13	136-5A203 321	5155022030	C2-1	Central	Westlake	Echo Park		2086.20	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Issued	10/24/2019 12:00:00 AM	ADDRESS	34.06675	-118.27931	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53563	19041-20001-51175	4312 N HAYVENHURST AVE	91436	5	165B137   217	2291005020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	01/13/2020 12:00:00 AM	ADDRESS	34.14943	-118.49465	***VOID***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53564	19041-10000-01900	14831 W BESSEMER ST	91411	6	177A149    46	2241024012	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	06/13/2020 12:00:00 AM	ADDRESS	34.18091	-118.45637	REMOVE HID INDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53565	15041-20000-40493	8000 W SUNSET BLVD C-110	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.09783	-118.36466	Change of use from retail to medical office. TI to existing commercial building. Plan check for power and energy. Total sqft. 1,397.Note: Building application has been created under 15016-20000-20920	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53566	16041-10007-01886	700-800 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Info Complete	05/11/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET UNDER DELTA 40.TITLE -24 ENERGY ONLY.INCLUDES: 1.ADDITION OF 2000 SQ.FT AND 3.5KW OF LIGHTING LOAD.2. ADDITION OF NEW RESTROOMS AND STORGE SPACES3.CHAGES TO FIXTURE COUNT4. ADDING 2 NEW BRANCH CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53567	18041-20000-23660	18559 W BRYMER ST	91326	12	213B125   282	2872019021	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.28104	-118.53699	Plan check for power only. Project scope is the addition of a Tesla PowerWall onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53568	16041-20000-11845	18355 W VENTURA BLVD	91356	3	171B125    79	2160008038	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.16757	-118.53255	Renovation of (E) single-story commercial restaurant space.  (N) 1000 A 120/208Y service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53569	17041-10000-04329	241 W WATCHORN WALK	90731	15	009B201     4	7440036906		Harbor				9800.31	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	33.72201	-118.28186	Plan check for Title 24 only in existing space  Replace outdoor HID fixtures with new LED fixtures. Total area: 114,850 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53570	15041-10000-29333	3838 S DUNN DR 1-87	90232	5	120B165  1263	4207004017	R5P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			09/04/2015 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.02219	-118.39883	PC FOR POWER AND ENERGY. NEW 7 STORY , 87 UNITS APARTMENT BUILDING. TOTAL AREA 51000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53571	15041-20000-30670	19601 W BASSETT ST	91335	3	183B117   740	2130009027	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.19612	-118.55996	PV1. NEW ROOF-MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 6.0 KW.(16) MODULES-LG LG300N1K-G4(2) INVERTERS- ABB PVI-3.0-OUTD-S-US-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53572	16041-20000-12522	22950 W VANOWEN ST SUITE A	91307	12	180B097    22	2038040006	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.19343	-118.62746	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR URGENT CARE MEDICAL OFFICE. 2000SQFT. SUITE A.  FIRST TIME TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53573	17041-10000-03365	3939 S VERMONT AVE	90037	8	117B197   994	5037019059	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.01361	-118.2919	Plan Check for power and energy for new 2 story High School Building. Service size: 1,200AB#17010-10000-00374	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53574	11041-10000-07665	6060 W SUNSET BLVD	90028	13	147A189    57	5545013043	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	06/27/2011 12:00:00 AM	ADDRESS	34.09786	-118.32167	T-24 lighting plan check only.  Permit to be issued on same application number.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53575	14041-10000-15434	3640 W WILSHIRE BLVD	90010	10	132B193    62	5093019018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			06/10/2014 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.06145	-118.30446	plan check for power and energy. 28 Typical units. fire alarm variance required. not methane. zone.BLDG#13010-10-01719: 7 Stories 209 Dwelling units Apartment w/  2 Basement Levels parking	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53576	13041-10000-04789	550 S CERES AVE	90013	14	126A215   134	5147015042	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	02/25/2013 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.04022	-118.24082	FA INSTALLATION OF AN AUTOMATICA AND MANUAL FIRE ALARM SYSTEM IN WAREHOUSE/OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53577	13041-20000-31773	10939 W PENDLETON ST	91352	6	198B173    11	2538012015	(Q)M1-1, [T][Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.24127	-118.3697	T24 FOR EXISTING WAREHOUSE/OFFICE. SCOPE OF WORK IN LAB.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53578	08041-10001-03829	440 S OCCIDENTAL BLVD 438-440	90057	1	135A201    58	5155011011	R4-1	Central	Westlake	Rampart Village	YES	2087.10	Electrical	Electrical	Public Safety Only			07/12/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	ADDRESS	34.065	-118.28357	EPC Methane Gas Dectection Sytem for apartment building (5 stories above grade/1story below grade).  (Plan checked & approved under # 08041-10000-03829 and plan was expired on 8/21/2009)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53579	17041-10000-32362	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.01366	-118.28294	Replace Fire control panels along with 210 devices on LA Memorial Coliseum	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53580	17041-10000-23640	3195 N GLENDALE BLVD	90039	13	154-5A207 219	5435026022	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Info Complete	07/21/2017 12:00:00 AM	ADDRESS	34.11796	-118.26127	RESTAURANT TI. PROVIDING NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53581	17041-10000-00921	11019 S MAIN ST	90061	8	088-5A203 363	6074017005	C2-1	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	33.93504	-118.27403	PC FOR ENERGY ONLY, T-24. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN (E) COMMERCIAL SPACE. TOTAL SQ. FT. 945.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53582	17041-10000-24431	8500 W BEVERLY BLVD LEVEL 8-ste 860	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	05/23/2018 12:00:00 AM		Issued	05/23/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR POWER AND ENERGY FOR A RESTAURANT TI ON THE 8TH FLOOR.  SCOPE INCULDE NEW DIST. BOARD, PANELS, CIRCUITS, LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 14168 SQ.FT.  INDOOR.PLAN CHECKER BE ADVICED  BEVERLY CENTER HAS VARIANCE IN PLACE FOR USAGE OF BUGEYES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53583	14041-10000-35469	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	33.94248	-118.40461	T24 for added new fixtures. Delta Airlines T-5 LAX. Total sq. ft. = 1045	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53584	16041-20000-13733	3507 S TROUSDALE PKWY 1st Floor	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.02187	-118.2846	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the restrooms. Total lighting area = 308 sq. ft.Note: Building plan check has been done under application 16016-10000-06647	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53585	14041-10008-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	33.95637	-118.3838	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 14 AND DELTA 15. SCOPE OF WORK INCLUDE CHANGES TO LIGHTING LAYOUT (REMOVAL OF FIXTURES AND ADDITION OF FIXTURES). NARRATIVE LETTER IS PROVIDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53586	17041-30000-24104	639 N NORTH BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.05972	-118.2398	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is (2) new trash and recycle enclosures. Total lighting area = 900 sq. ft.Note: Building application has been generated under 16016-10000-09348	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53587	16041-20000-01387	15821 W VENTURA BLVD Suite 425	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Expired	02/13/2018 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for energy only. TI to office on 4th floor of existing high rise building. New lighting (incl. emergency) and receptacles. 4,250sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53588	17041-10000-39724	110 W 4TH ST LV1-LV2	90013	14	129A211    69	5149022013	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.04828	-118.24772	PC FOR OFFICE TENANT IMPROVEMENT ON THE FIRST AND SECOND FLOORS.SCOPE INCLUDES NEW PANELS LIGHTS AND RECEPTACLES WITH NEW EQUIPMENT. TOTAL AFFECTED AREA 6696 SQ.FT. PLAN CHECK IS FOR TITLE 24 ONLY  B# 17016-10000-25487	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53589	14041-10000-11208	3037 N ARROWHEAD DR	90068	4	156B185    85	5577035011	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.12419	-118.32767	PV1, INSTALL 9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL WITH OPTIMIZER.(2) TRANSFORMERLESS INVERTER(S): SOLAREDGE SE6000A-US-ZB-U AND SE3000A-US-ZB-U(36) TRINA SOLAR # TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53590	17041-10001-21313	2805 S MCCONNELL DR	90064	5	126B165   650	4308014010	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.04091	-118.40132	Supplementeal for rooftop expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53591	11041-10000-22052	6500 W WILSHIRE BLVD #100	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM			PC Approved	11/17/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	title 24 for portion of indoor and out door	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53592	17041-10001-33261	8758-8762 W PICO BLVD 8760 &-8762	90035	5	132B169  1007	4303001002	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.05445	-118.38292	PC FOR LOST SET OF PLAN. THIS IS PLAN CHECK ONLY. PERMIT TO BE PULLED UNDER MASTER.  PC FOR fire damage repair FOR TITLE 24 ENERGY ONLY ALL EQUIPMENT REPLACED IS ONE TO ONE. TOTAL AFFECTED AREA 8930 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.B#17016-30000-23140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53593	19041-10000-14820	8860 N TYRONE AVE	91402	6	195B149   274	2639005005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.23163	-118.44815	PV1, system size is 5KWac/5.49KWdc.  Scope of work includes 18 modules (Candian Solar CS6K-305MS) with optimizers (P320)  and a central inverter Solar Edge (SE5000H-US).  Panel upgrade pulled under a seprate express permit ( 19041-10000-14403)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53594	18041-10000-32894	110 W 11TH ST 5th-7th FLR	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Expired	11/16/2022 12:00:00 AM	ADDRESS	34.0392	-118.25858	Full plan check for first time tenant T.I. Scope include new lighting and equipment for 5th, 6th and 7th floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53595	18041-10000-44600	355 S GRAND AVE 14TH FLR.	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.05191	-118.2525	TI FOR A CORRIDOR AND ELEVATOR LOBBY IN A HIGH-RISE 14TH FLOOR. SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1863 SQ.FT. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53596	18041-20000-29051	4212 N LANKERSHIM BLVD	91602	4	165B177   892	2423024044	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.14626	-118.36314	Plan check for power and energy for T.I. of existing restaurant, Service upgrade to 600A. Total area: 4771 sq ft. B#14016-10000-15144	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53597	18041-10000-04508	563 N HOOVER ST	90004	13	141A201   145	5539028004	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Public Safety Only			02/07/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.08125	-118.28469	PC FOR NEW FA  IN APARTMENT BUILDING. SCOPE INCLUDES 2 PANELS  AND 46 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53598	14041-10000-05050	1900 AVE OF STARS 5TH FLOOR	0	5									Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM				T24 ONLY FOR A COMMERCIAL BUILDING. TOTAL AREA IS 1168.5 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53599	11041-20000-12911	7789 W FOOTHILL BLVD	91042	2	204B193   163	2558001028	QC2-1VL, QP-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10, 1031.02	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.25909	-118.30244	Installing new ights and receptales to addition for Vons Pharmacy.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53600	16041-20001-33162	3854 N VALLEY MEADOW ROAD	91436	5	162B141   182	2286019014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2016 12:00:00 AM			Reviewed by Supervisor	10/07/2016 12:00:00 AM	ADDRESS	34.14087	-118.47852	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of roof mounted solar array on SFD. Interconnect with 400A MSP.12.8kW ungrounded system. (40) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53601	19041-10000-24678	6137 N LANKERSHIM BLVD	91606	2	177B169   474	2338006027	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.05	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.18226	-118.38534	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53602	13041-10000-09452	3722 S MILITARY AVE	90034	11	117B161   827	4252014030	RD2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.01622	-118.415	PV1 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 2.97 KW. TRANSFORMERLESS. 12 MODULES AND 1 INVERTER. [INVERTER: SOLAR EDGE SE3000A-US] [PV MODULE: TRINA SOLAR TSM-245PC05/PA05.18].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53603	10041-20005-15146	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM			PC Approved	09/05/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	Plan check for power and energy. Podium floor. 1425 conditioned + 920 unconditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53604	12041-20000-08149	19630 W FRIAR ST	91335	3	177B117    16	2132017006	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	05/08/2012 12:00:00 AM	ADDRESS	34.18547	-118.56114	8.55KW roof mounted P.V. system with change of existing services main circuit breaker to 175 amperes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53605	14041-10000-33074	1017 N LAS PALMAS AVE	90038	4	144B185   896	5532026036	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.08943	-118.33642	NEW FIRE ALARM SYSTEM WITH ONE PANEL  AND 86 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53606	19041-10000-02018	1925 S CENTURY PARK EAST STE 1300-&1380	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	ENERGY PC FOR TITLE 24 ONLY FOR EXISTING COMMERCIAL OFFICE SPACE. TOTAL SQUARE FOOTAGE = 6017.34 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53607	16041-10002-18374	12030 W RYNGLER ROAD	91604	2	162B165   675	2369019031	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.13985	-118.39295	Note: plan check fee is $0 due to senate bill 1222. 8/30/16: This is plan check only, changes to approved set of plans. Rearrangement of solar panels. Note changes delta 1. Permit under master plan E# ((((Note: Permit is $0 due to senate bill 1222New 12 kW AC PV installation. 44 Canadian Solar PV modules. Installing 2 SMA SB6000TL-US Inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53608	12041-10001-18053	940 W HARRY BRIDGES BLVD GUARD-HOUSE	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Closed	02/07/2014 12:00:00 AM	PIN	33.77046453	-118.27163726	PLAN CHECK NEW FIRE ALARM SYSTEM FOR GUARD HOUSE. PORT OF LA  (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53609	17041-20001-38540	8870 N TAMPA AVE	91324	12	195B117    63	2783025083	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.23179	-118.55382	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on commercial building.Total system size: 33.3kW ungrounded.(1) 33.3kW SolarEdge inverter.(120) 360W pv modules.(60) 800W power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53610	12041-20000-14549	14708 W VENTURA BLVD	91403	5	166-5A149  67	2276002020	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	05/22/2013 12:00:00 AM	ADDRESS	34.15154	-118.45347	First time tenant (Panera Bakery) to approved core and shell building.  Install subpanels, branch circuits, and lighting.  Plan check for fire alarm, power, and energy.  Fire alarm is submitted seperatly	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53611	10041-20000-05395	17100 W VENTURA BLVD	91316	5	168B133    80	2289005012	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM	04/29/2010 12:00:00 AM		Permit Finaled	08/04/2010 12:00:00 AM	ADDRESS	34.16003	-118.50552	roof mounted PV system. PERMIT FEE WAS RECALCULATED CONSIDERING PERMIT PAID ON APPLICATION 10041-20000-02702.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53612	19041-20000-53281	9135 N RESEDA BLVD	91324	12	198B125   245	2763034001	(T)(Q)C2-1L, C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	07/10/2020 12:00:00 AM	ADDRESS	34.23639	-118.53634	PLAN CHECK FOR ENERGY ADD NEW LIGHTS AND EQUIPMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53613	14041-10000-26304	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.05554	-118.41342	Title 24 only for remodeling (2) public restrooms in a high rise office commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53614	15041-20000-36202	11221 N ILEX AVE	91331	7	210B157   181	2616020016	M1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	34.27369	-118.43246	Plan check for Title 24 only for  Torres Iron Works. Total area: 2,725 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53615	13041-10001-16311	301 WORLD WAY	90045	11	090B161    33	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM			PC Approved	11/05/2014 12:00:00 AM	ADDRESS	33.94423	-118.40709	][][] supplemental to existing work under 13041-10000-16311 (not yet approved) . supplemental is to account for the addition of lighting work in parking garage elevator and lighting upgrade. total projected area in new scope of work is 357558 sq ft of illuminated area. Since the area is > 30,000 sq ft it could not be charged under submittal-2 fee under the original 10000-series application, which was marked over the counter. ][][][plan check only. permit to be pulled under original permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53616	18041-10000-44393	2025 S AVENUE OF THE STARS	90067	5	132B161   724	4319004***	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	03/21/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	NEW METHANE DETECTION SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53617	15041-10001-31696	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Special Equipment			12/02/2015 12:00:00 AM			PC Info Complete	12/02/2015 12:00:00 AM	ADDRESS	33.79173	-118.23549	12-2-2015 M.Z  changes to previosly approved set. added over load protection on the bus.                                                                  INSTALLING A 1250 KVA, 15KV/480V 3 PHASE POWER DISTRIBUTION TRANSFORMER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53618	13041-10000-26829	10250 W CONSTELLATION BLVD	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.05735	-118.41746	PV2.  NEW ROOF MOUNTED PHOTOVOLTAIC SYSTEM. SYSTEM SIZE 136,800 kW DC. 120,531 AC. TRANSFORMER LESS INVERTER.   ZERO PERMIT FEE CAP DUE 2012 SB1222(456) ASTRONERGY CHSM6612P 300W MODULES(3) SNA SUNNY TRIPOWER 20000TL-US 20KW (480V)(2) SNA SUNNY TRIPOWER 15000TL-US 15KW (480V)(2) SNA SUNNY TRIPOWER 12TL-US 12KW (480V)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53619	18041-10001-47864	2801 1/2 S VINEYARD AVE	90016	10	123B181  1294	5057010013	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.0311	-118.34477	PC FOR A SOLAR PV (APATMENT BUILDING,COMMERCIAL). SYSTEM CONSIST OF 8 MODULES (Q.PEAK-G4.1/SC 295-305). 1 CENTRAL IVERTER (ABB UNO-DM-3.3-TL-PLUS-US).1-125A LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53620	14041-10000-27952	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Expired	03/09/2017 12:00:00 AM	ADDRESS	34.20103	-118.38536	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR KAISER PERMANENTE HOSPITAL. 1 STORY. 78,000 SQFT, EMEREGENCY LIGHTING.((((((    2-13-15  M.Zandi  customer agrees to bring new sheet of these plans with new UL labels reflecting the the new amp rating for the retro fit fixtures. , This is to be brought back to plan check for re-stampping by 2-27-15.)))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53621	13041-20000-25007	1210 W CHANDLER ST	90744	15	036B201   252	7414018012	R1-1XL	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	33.79578	-118.27782	Modification to approved set of plans on 13041-20000-19056.  Plans now show 200 Amp bus vs. 225 Amp Bus.  Service upgrade and panel must be on a separate permit.  PLAN CHECK ONLY for PV portion.        <<<PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW. USING 16 MODULES. CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.>>>	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53622	19041-10000-30741	3724 S CRENSHAW BLVD	90016	10	117B185   240	5033001039	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.01932	-118.33437	PLAN CHECK FOR POWER AND ENERGY T.I AT EXISTING WALGREENS EXAM ROOMS. SCOPE OF WORK INCLUDES NEW LOADS AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53623	16041-10000-26153	11868 N PHILLIPPI AVE	91331	7	216B161   495	2527004007	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.28594	-118.41521	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. USING LADBS'S STANDARD PLAN. (25)MODULES-RENESOLAR JC250M-24/BB(1)INVERTER-FRONIUS PRIMO 6.0-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53624	18041-10000-43449	17915 W ERWIN ST	91316	5	177B129    15	2123022022	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.184	-118.52364	PLAN CHECK FOR ROOF MOUNTED 10KVA PV SYSTEM REMOTELLY MOUNTED ON GARAGE CONSISTING OF 1 CENTRAL INVERTER(10000H-US) WITH 35 MODULES USING P320 OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53625	19041-10000-18397	5122 N ENCINO AVE	91316	5	171B129   235	2257014038	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.16442	-118.51393	Note: Fees are $0 due to AB 1414 and Senate Bill 1222.(ePlan) PLAN CHEKC FOR ROOF MOUNTED 17.39KWdc / 15.04 KWac PV SYSTEM CONSISTING OF 47AC MODULES(SPR-X22-370-D-AC) CONNECTED TO AN EXISTING 400A MAIN PANEL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53626	16041-20000-21721	6200 N VARIEL AVE	91367	3	177B109     7	2149004007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			06/21/2016 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.18341	-118.59258	New mixed use apartment building 241 dwelling units, 4 guest rooms, retail and office space. Total area: 158,000 sq ft.  (3) 3000A 208Y/120V, (1) 1600A 208Y/120V, and (1) 800A 208Y/120V services to the building.Building permit # 16010-10000-01844	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53627	18041-20001-30696	17891 W RIDGEWAY ROAD	91344	12	216B129   336	2601032037	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM			PC Approved	09/26/2018 12:00:00 AM	ADDRESS	34.2851	-118.52415	Expedited plan check fee.PV1.  Install 7.50 kW DC/6.53 kW AC-CEC ground mounted grid tied PV system.  (25) modules with 6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53628	17041-10000-46388	2001 N HILLCREST ROAD	90068	4	150B181   386	5549021038	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.10683	-118.34049	PC FOR NEW FA SYSTEM FOR THREE STORY BUILDING WITH SUBTERRANEAN BASEMENT. INSTALLING ONE FACP, RPS PANEL AND 32 DEVICES. INSTALLING WIRELESS HEAT AND SMOKE DETECTORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53629	13041-10000-09170	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	POWERING IEMS VIDEO BO. EXISTING SERVICE AND 8 NEW PANELS. WORK LOCATED IN CORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53630	15041-20000-08899	21650 W OXNARD ST Suite 1960	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for T-24 only T.I. existing office remodel. Total area: 1953 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53631	10041-20000-25503	12780 N CHALON ROAD	90049	11	141B137    49	4493005011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2010 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Finaled	12/06/2011 12:00:00 AM	ADDRESS	34.08327	-118.49819	Plan check for new ground mounted 16.17 KW Photovoltaic system for single family in addition to previously approved roof mounted system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53632	15041-10000-41422	5701 S ST ANDREWS PL	90062	8	108B193  1037	5005023015	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	33.99079	-118.31148	PV1, INSTALL 9.01  KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(34) MODULES: KYOCERA KU2656ZPA(1) INVERTER: FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53633	11041-10001-03353	3909 W OLYMPIC BLVD	90019	4	132B189  1243	5092016012	C2-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.05371	-118.31989	CHANGES TO LIGHTING SYSTEM AND CONVERTING PART OF THE RESTAURANT AREA  TO ENCLOSED OFFICES ; NO CHANGES TO THE SINGLE LINE DIAGRAMPROPOSED TENANT IMPROVEMENT W/IN AN  EXISTING OFFICE, RESTAURANT AND GYM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53634	19041-20000-15913	1811 S MESA ST	90731	15	012B201   778	7456029029		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	33.72757	-118.28601	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR NEW SFD. SYSTEM SIZE IS 3.02KW DC/2.88KW AC. SCOPE OF WORK INCLUDES (9) SUNPOWER PV SYSTEMS WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53635	19041-20000-45338	4920 N VAN NUYS BLVD	91403	4	169-5A151  47	2248007139	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			11/05/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	02/26/2021 12:00:00 AM	ADDRESS	34.15995	-118.4485	INSTALL (446) NEW FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53636	15041-20000-07771	12100 W OLYMPIC BLVD	90064	11	123B149   575	4259025019	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM			PC Approved	03/17/2015 12:00:00 AM	ADDRESS	34.03215	-118.45396	Plan check for Title 24 only. Project scope is a tenant improvement. Total lighting area = 7,068 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53637	17041-20001-45733	18801 W PASADERO DR	91356	3	165B121   330	2177020011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.14847	-118.54338	EXPEDITE PER APPLICANT REQUEST.Plan check for a SFD roof-mounted PV system and DC coupled battery backup system. PV system size is 15.2 kWac and consists of (2) 7.6kW inverters, (46) 335W pv modules, (46) 370W power optimizers, (2) 5kW batteries, and (3) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53638	16041-20000-24474	735 S FIGUEROA ST STE 170	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.04878	-118.26079	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 705.  SCOPE OF WORK IN SUITE 170.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53639	19041-20001-42672	4817 W ROUND TOP DR	90065	14	160-5A219  31	5683035007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.13592	-118.22507	Revisions to approved set.  Revised distribution/interconnection details, change of wire size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53640	10041-10000-18243	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			09/15/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	02/01/2011 12:00:00 AM	ADDRESS	34.07594	-118.35916	new pv system for CBS bldg, 100 and 260 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53641	14041-10000-35156	1656 W 36TH PL	90018	8	120B193  1423	5041022014	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.02178	-118.30766	PV1, INSTALL 2.805 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(11) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53642	15041-20000-22505	2097 W 29TH ST	90018	10	123B193  1153	5053003002	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.02926	-118.31183	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53643	16041-10000-44009	10250 W SANTA MONICA BLVD # 1580	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Kiehl's"" Ste. 1580.  Install new Xrfmr, and  panels, total area 1180 sq.ft*** New load is 38 A demand load to MS-ELA42"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53644	19041-20000-49892	2751 N GLENDOWER ROAD	90027	4	153B197    78	5588011030	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.11651	-118.2964	Plan check for PV roof mounted system, PV system size: 7.6KW AC, 5.16KW AC CEC with 17 PV Modules  and 1 LG battery 9.8kWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53645	10041-20000-11630	8723 W ALDEN DR 3RD FL	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM			PC Approved	06/17/2010 12:00:00 AM	ADDRESS	34.0754	-118.38272	CSMC  user requested changes to approved plans 10041-20000-03934 ( plans were approved & permitted ).Power only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53646	18041-20002-34027			13	144A203   261	5427026007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM			PC Approved	09/26/2018 12:00:00 AM	PIN	34.08815273	-118.2765378	09-26-18 Changes to an approved set of plan. Changes include update to current limiter track. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53647	16041-10000-13374	14394 W VENTURA BLVD 1st floor	91423	4	166-5A151 191	2266002054	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	34.15018	-118.44568	PC for energy only to an existing bank (Banc of California) 2 story building plus garage. All equipment is existing. Adding new lighting and power. Total sqft =  2439.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53648	13041-10001-04706	810 S SPRING ST #B2	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.04268	-118.25375	MODIFICATION TO APPROVED SET OF PLANS. MODEL AND MANUFACTURER CHANGED FOR L3 AND L4 LUMINAIRES.*******************************************************PLAN CHECK POWER AND ENERGY FOR RESTAURANT (UNIT #B2) TI. OCCUPANCY OVER 100. ENERGY FEES PAID UNDER APPLICATION #13041-10000-04701.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53649	18041-20001-30350	1249 N SHADYBROOK DR	90210	5	144B157   140	4357017013	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.09363	-118.42976	Revisions to approved set of plans.  Change of inverter from microinverters to (2) 7.6 kW rated string inverters, module count increased to (64) total.  (((Plan check for a PV1 roof-mounted PV system. System size is 17.98 kWdc/15.86 kWac-CEC and consists of (62) micro-inverters, (62) modules, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53650	17041-20000-41281	19701 S HAMILTON AVE Ste 160	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	33.85221	-118.28625	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53651	12041-10000-01743	801 S FIGUEROA ST	90017	14	129A207   153	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Approved	01/24/2012 12:00:00 AM	ADDRESS	34.04789	-118.26153	"TI TO (E) RESTAURANT; REPLACING ENTRANCE DOORS TO EXISTING RESTAURANT & PATIO, CONSTRUCTION OF NEW BAR IN EXISTING BAR AREA, CONSTRUCTION OF NEW ""FEATURE WALL""; REPLACE STOREFRONT TO (N) ENTRANCE DOOR"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53652	16041-10000-39323	429 W 106TH ST	90003	8	090A201   249	6061031012	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2412.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	33.9402	-118.28164	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.1 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53653	17041-10000-36846	6303 S MAIN ST	90003	9	105B201  1045	6005023022	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	33.98221	-118.2741	REPLACE OUTDOOR EXISTING FIXURE WITH  NEW LED FIXURE - TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53654	18041-20000-18752	5110 N WHITSETT AVE	91607	2	171B165   793	2356020011	R1-1, RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			05/21/2018 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	11/06/2020 12:00:00 AM	ADDRESS	34.16343	-118.40506	Plan check for power and energy. Project site is a 3-story, 15-unit apartment over 1 level of basement parking garage. Work includes a 1,200 Amp service and a total lighting area of 24,367 sq. ft.Note: Building application has been generated under 17010-10000-05170	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53655	17041-10001-25693	16058 W ANOKA DR	90272	11	132B125   110	4420006005	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2017 12:00:00 AM			PC Approved	08/07/2017 12:00:00 AM	ADDRESS	34.0535	-118.53399	EXPEDITE PER APPLICANT REQUESTPC FOR ROOF MOUNTED PV SYSTEM ON SFD. SYSTEM SIZE IS 18KW ACSCOPE INCLUDES 62 MODULES WITH OPTIMIZERS.ZONING NEED TO BE DONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53656	10041-10000-06405	3415 S SEPULVEDA BLVD 9th Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.02055	-118.42347	"Plan check T-24 Energy (general/emergency) lighting on the 9th floor TI. ""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53657	18041-10000-40659	111 E UNIVERSAL HOLLYWOOD DR 3,5,7 & 10-FLRS.	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.13855	-118.36112	TITLE 24 ONLY. RENOVATE AND UPGRADE RESTROOMS ON 3RD, 5TH, 7TH AND 10TH FLOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53658	18041-10000-46213	11136 N BALBOA BLVD	91344	12	210B133   327	2682021032	C4-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.27311	-118.50197	T-24 plan check. Change of use from Retail to Restaurant. Scope of work includes new lighting and receptacles. Total sq. ft. 957.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53659	17041-20003-11832	17075 W DEVONSHIRE ST	91325	12	204B133   139	2695020031	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Approved	01/22/2018 12:00:00 AM	ADDRESS	34.2577	-118.50483	Plan check only for review of lost set of plans.  (((PV2.  Install roof-mounted PV system sized 57.6kW interconnected with MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53660	18041-20000-17288	17501 W RAYEN ST	91325	12	195B129   200	2768026009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.23232	-118.51605	Plan check for PV roof mounted system, system size: 19.55kWac with 85 modules and 85 microinverters connected to MSP via line side connection.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53661	13041-10000-20254	9790 W BURNLEY PL	90210	5	156B157   267	4385022023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.12379	-118.43023	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A STANDARD PLAN. SYSTEM SIZE IS 4.9 KW DC AND 4 KW AC. USING 20 MODULES IN TWO STRINGS. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: FRONIUS # IG 4000]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53662	12041-10000-30867	6507 W SUNSET BLVD	90028	13	147A187   133	5547017014	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM			PC Approved	12/28/2012 12:00:00 AM	ADDRESS	34.09815	-118.33133	T24 FOR RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53663	16041-20000-21783	5243 N BOTHWELL ROAD	91356	3	171B117   150	2164019006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.16732	-118.56134	PV1ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53664	13041-20000-23238	616 N LA JOLLA AVE	90048	5	141B173   733	5528011014	R1-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.08205	-118.36785	New rooftop PV System on an existing 2-unit residential building.  System uses Enphase Microinverters.  Plan check is only for PV system, NOT for service upgrade or de-rating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53665	13041-10000-02782	10250 W SANTA MONICA BLVD SUITE FC-2	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	03/14/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	13041-10000-02782T24 FOR REMODEL OF A CHIPOTLE RESTAURANT IN CENTURY CITY MALL FOOD COURT.   STORE #2095, SUITE FC-2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53666	17041-10003-33475	11924 W FOOTHILL PL	91342	7	210B165   107	2532012038	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			PC Approved	11/28/2018 12:00:00 AM	PIN	34.27497571	-118.39643615	[[[11/28/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES TO COOLERS TYPE AND SIZE, RMOVING AND REALLOCATING LOAD]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53667	17041-20000-30953	16000 W VENTURA BLVD Suite 440	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.15584	-118.48164	Plan check for energy only. TI to existing office suite 440 in high rise building. New lighting (incl. emergency) - 997sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53668	17041-10000-26104	9301 N WINNETKA AVE	91311	12	198B113   122	2748038032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Issued	08/01/2017 12:00:00 AM	ADDRESS	34.23934	-118.57134	TITLE 24 PLAN CHECK FOR REMOVAL OF (22) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA = 62,600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53669	17041-10000-46306	8720 N BALBOA BLVD	91325	12	195B133   419	2688041038	C1-1VL, C2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.22939	-118.50239	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53670	16041-20001-30985	18957 W CARMEL CREST DR	91356	3	162B121   162	2177048014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.14115	-118.5437	EXPEDITE PER APPLICANT.PV1INSTALL ROOF MOUNTED PV SYSTEM WITH BATTERY BACK UP SIZED 7.6KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53671	17041-20000-43713	8421 N ZEILER AVE	91402	6	192B157   493	2637014056	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.22353	-118.42553	PV1.  Install 3.9kW roof mounted grid tied PV system.  (12) panels with 7.6 kW rated central inverter and 9.8 kWh battery backup system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53672	15041-20001-17775	19143 W VICTORY BLVD #6	91335	3	180B121   534	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/09/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.18674	-118.55078	Expedite per applicant request[[[[[Plan check for PV roof mounted system on appartment unit 6. System size: 6.0kW]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53673	13041-10001-36204	11958 W BURTON ST	91605	6	192B165   616	2310003010	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	34.22061	-118.3938	EXPEDITED rses PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL ROOF-MOUNTED SOLAR  , INTERCONNECTING TO (E) 200A MAIN IN A  HOUSE. non-standard plan. SYSTEM SIZE IS 4 kW DC. (16)power  optimizers:Solaredge Op250-LV-MC4SM-2NA-Z   (16)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3800A-US}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53674	12041-10000-30354	8366 W 3RD ST	90048	5	138B173   844	5511031023	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Approved	12/18/2012 12:00:00 AM	ADDRESS	34.07268	-118.37231	"PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT FOR ""JUICE SERVED HERE'."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53675	10041-10000-19567	11757 W CHENAULT ST	90049	11	132B145   386	4401013003	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.05511	-118.46941	NEW SINGLE FAMILY HOUSE. 2 LEVELS BELOW GRADE  (29,988 SQR FT) AND 2 LEVELS ABOVE GRADE (11,317 SQR FT).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53676	19041-20001-27653	3792 N WINFORD DR	91356	5	165B125   112	2184013018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM			PC Approved	08/01/2019 12:00:00 AM	ADDRESS	34.13809	-118.55311	expeditepv1install roof mounted pv system sized 15.2KW AC interconnected with msp.(4) tesla ESS each rated at 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53677	14041-20001-05005	6626 N KENTLAND AVE	91307	12	180B101   285	2038031010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.19098	-118.61745	((EXPEDITE FEES)))pv1 single family dwelling. total system size 6.6kw ac using microinverter. enphase m215. nonsandard plan	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53678	11041-20001-25683	4541 N COLFAX AVE	91607		168B169   967	2364007043	[Q]RD1.5-1		Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City			Electrical	Electrical	Apartment			03/16/2012 12:00:00 AM			PC Approved	03/16/2012 12:00:00 AM	ADDRESS	34.15324	-118.38793	energy plan check apartment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53679	14041-10000-15759	1028 S WESTWOOD BLVD	90024	5	132B153    38	4363020008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.06195	-118.44516	Installation of new fire alarm devices in existing retail store, TI to meet proper area coverage per NFPA 72	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53680	17041-20000-45881	5757 W WILSHIRE BLVD 3rd Floor	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.06259	-118.35341	Replacement of 1200A 480Y/277V switchboard in 3rd floor electrical room.  Replacement of 600A 240V 3ph panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53681	13041-20000-10352	14500 W SHERMAN CIR	91405	6	183B149   800	2219007034	(T)(Q)RAS3-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			04/22/2013 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.19972	-118.44963	Plan check for new 284 appartment. NOT a methane hazard site. Fire Alarm Variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53682	10041-10000-08905	12811 S FIGUEROA ST	90061	15	081B201   272	6132003030	M2-1VL-O, P-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	07/12/2010 12:00:00 AM	PIN	33.91597635	-118.28400452	Ti in an existing ofice building. Plan check for T24 and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53683	19041-20001-32290	8408 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM				10-11-2019 Changes to an approved set of plan, Changes to an approved set of plan, relocate PV disconnect. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53684	14041-20001-03539	12610 W HAVELOCK AVE	90066	11	105B157   500	4221027030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	33.98428	-118.42274	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.SUPPLEMENTAL TO ORIGINAL APPLICATION. THIS WILL PERMIT 12 MODULES. NO OTHER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53685	19041-30000-38435	2029 S CENTURY PARK EAST #980	90067	5	132B161   697	4319016029		West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY ONLT, INTERIOR T.I. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN A PORTION OF THE FLOOR. TOTAL SQ. FT. 5079	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53686	14041-10000-21255	625 W 121ST ST	90044	15	084B201  1261	6117002018	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	33.9228	-118.28568	Installation of roof mounted solar PV system.  Total system size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53687	15041-20002-23703	15800 W STRATHERN ST Bldg. 3	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Approved	12/22/2016 12:00:00 AM	ADDRESS	34.21559	-118.47752	Changes made to (E) panel AIC ratings to reflect (E) site conditions.  APPROVAL FOR DELTA-7 CHANGES ONLY.  CHANGES MADE TO E0.2 AND E0.5 SHEETS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53688	16041-10000-25486	407 N ARDMORE AVE	90004	13	138B193   162	5521023013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	34.07789	-118.30254	Full plan check for a new 3 story 6 unit apartment building.  Subterreanean garage, with upper 2 levels of residential.  2 typical units.  New service rated at 600 Amps 120/240V 3phase 4Wire.  4,654 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53689	16041-10000-13867	8707 N SHIRLEY AVE	91324	12	195B117   178	2783025802	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.22881	-118.55807	INSTALLATION OF NATURAL GAS FUEL CELL ON PRECAST CONCRETE PAD.  DERATE MAIN BREAKER FROM 2,500 A to 1,600 A TO ACCOMIDATE 800 A BACKFEED BREAKER.  FUEL CELL WILL CONNECT TO 1,000 A BUS WHICH REPLACES EXISTING 800 A BUS.  MAIN SWITCHBOARD TO BE RE-LISTED BY A CITY OF LOS ANGELES APPROVED ELECTRICAL TEST LAB.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53690	19041-20001-05931	10536 W GARWOOD PL pv1	90024	5	135B153   143	4360020014	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.06808	-118.43489	expeditepv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53691	11041-10000-26045	700 W WORLD WAY #7D	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	Plan check power and energy. New Restaurant Space-7D (Wolfgang Puck Express) at Terminal 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53692	15041-10000-42992	116 N ROBERTSON BLVD 2nd fl	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.0758	-118.38356	PC for energy only to a commercial building. Adding new lighting and power to a screening room. Total sq ft =2000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53693	16041-10000-39324	1726 S 5TH AVE	90019	10	126B189   731	5072022018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Expired	09/08/2023 12:00:00 AM	ADDRESS	34.041	-118.3223	Installation of new roof mounted solar PV array on existing two family dwelling.  Total system size = 1.5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53694	18041-10000-01210	682 W 9TH ST	90731	15	015B197   799	7454005049	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	33.73624	-118.29185	PC for new FA system for single story building. Installing 13 devices and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53695	12041-10000-19441	21505 W RINALDI ST	91311	12	210B105   275	2723004020	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM			Verifications in Progress	12/19/2012 12:00:00 AM	ADDRESS	34.27132	-118.59951	PLAN CHECK POWER AND ENERGY. 1 NEW SINGLE STORY MULTI PURPOSE ROOM (BLD 1 B) FOR CHARTER SCHOOL (APPLICATION 2 OF 6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53696	14041-10000-07221	746 W 11TH ST	90731	15	015B197  1184	7454014013	RD2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Expired	04/12/2016 12:00:00 AM	ADDRESS	33.73436	-118.29347	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN FOR CENTRAL TRANSFORMERLESS INVER SYSTEM. SYSTEM SIZE: 2.5 KW.(10) CANADIAN SOLAR # CS6P-250(1) POWER ONE # AURORA PVI 3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53697	18041-10000-15653	1422 W 11TH ST	90015	1	129A205   312	5137024213	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.04661	-118.27321	PLAN CHECK FOR POWER ONLY - CHANGE OF USE FROM WAREHOUSE/OFFICE TO NEW CORE & SHELL I-2.1 OCCUPANCY ( EXEMPT FROM T24) FOR FUTURE DIALYSIS CLINIC USE.  PROJECT IS SHELL RENOVATION (ONLY).SCOPE INCLUDES TAPPING TO EXISTING SERVICE, ELECTRICAL COMPONENTS AND TITLE 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53698	10041-20000-12060	6820-6826 S CENTINELA AVE	90230	11	105B165   433	4220014026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	ADDRESS	33.98415	-118.40155	NEW SERVICES, PANELS,  CIRCUITS.  TWO BUILDING IN ONE APPLICATION. 6820 AND 6820 CENTINELA AVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53699	18041-10000-45661	11675 W PICO BLVD	90064	11	123B149   587	4260027045	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.03195	-118.44551	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53700	14041-10003-03293	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	NEW CIRCUITS AND HEAT PUMPS FOR EACH OF THE THREE RETAIL SPACESThis a high rise 12 story office building, converte to a hotel , 231 guest rooms. power, lighting , indoor and out door title 24, fire alarm deffered, deisel fire pump.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53701	19041-10000-14932	7300 N DEERING AVE	91303	3	186B105   868	2112025029	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.20295	-118.5965	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53702	13041-10000-34309	1540 E ALCAZAR ST G-24 LAB-G-25 LAB	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.06338	-118.20434	TITLE 24 PART 6 ENERGY ONLY PLAN CHECK, LIGHTING WORK FOR G-24 AND G-25 COMPOUNDING LAB. PROJECTED AREA IN LIGHTING WORK IS APPROXIMATELY 3192 SQ FT, AND INCLUDES EMERGENCY LIGHTING.  SCOPE OF WORK < 400A. INDOOR WORK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53703	15041-20002-13938	9000 N RESEDA BLVD 103	91324	12	195B125   108	2769001022	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	ADDRESS	34.23439	-118.53589	7.27.2015 - Supplemental plan check for First Time Tenant. Plan check for power only. (energy compliance checked under parent application)TI TO SUITE 103. NEW LIGHTING. PC FOR ENERGY ONLY. T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53704	14041-20000-13633	7951 N HESPERIA AVE	91335	12	189B125   403	2101023013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Expired	07/15/2016 12:00:00 AM	ADDRESS	34.21524	-118.52644	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 6.885kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(27) Trina Solar #TSM-255PA05.18 pv modules(27) SolarEdge #P300 power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53705	19041-20000-22193	22135 W ROSCOE BLVD LOT #20	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 20.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53706	15041-10001-20238	610 W FLORENCE AVE	90044	8	102B201   919	6020028005	C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	33.97439	-118.28428	Supplemental PC and Permit: Change Panel HP (1-phase) to Panel HPB (3-phase), add Panel HPA (100A 3-phase). Relocate Electrical Equipments to Unit B1. No additional change on T-24.<<<Full plan check for service upgrade from (2) 200-Amp single phase 120/240 to (1) 800-Amp 3-phase 4-wire 120/240V; All existing load will reconnect to new service equipment. Total T24 area is 6805-SQ feet.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53707	14041-20000-15481	6951 N COLUMBUS AVE	91405	6	183B145   407	2220021010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.19727	-118.46378	PV1Central Transformerless Inverter standard plan.Install roof-mounted solar array on SFD. System size: 6kW(2) Sunny Boy 3000TL-US-22 transformerless inverter(27) Hyundai HIS-245MG pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53708	17041-10000-37763	2828 N GLENDALE BLVD	90039	4	151-5A207 129	5438019012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Issued	10/24/2017 12:00:00 AM	ADDRESS	34.1082	-118.26347	PC FOR CHANGE OF OF USE FROM CHURCH TO SCHOOL TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS. OCCUPANT LOAD<100 TOTAL 8100SQ.FT. THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER 17041-1000-37065B# 17016-2000-02365	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53709	17041-30000-10899	8620 S AIRPORT BLVD	90045	11	096B169   631	4125009020	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Issued	06/02/2017 12:00:00 AM	ADDRESS	33.95899	-118.38536	PC FOR TITLE 24 IN A 6 STORY HOTEL. FOR FLOORS 2-6.TOTAL AFFECTED AREA OF 6000 SQ.FT. SCOPE INCLUDES NEW LIGHTS IN CORRIDORS, ADA GUEST ROOMS AND STORAGE ROOMS INCLUDES LIGHTS AND NEW RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53710	18041-10000-47297	655 E GAGE AVE	90001	9	105B205   892	6007010015	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM			Corrections Issued	12/13/2018 12:00:00 AM	ADDRESS	33.98212	-118.2631	PLAN CHECK FOR SERVICE UPGRADE TO 1000amps, 277V/480V, FOR FUTURE PLANT GROWTH FACILITY. CORE AND SHELL ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53711	11041-20000-05029	515 S FLOWER ST 21 Floor	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	03/15/2011 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	T.I.  to existing high rise building.  Install general/emergency lighting partial of 21st. floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53712	14041-10000-00984	1225 N BEVERLY ESTATE TER	90210	5	144B157   160	4356012004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Expired	03/08/2016 12:00:00 AM	ADDRESS	34.09311	-118.42848	PV1, Install 13.39 kW DC roof-mounted solar array for a two story house, interconnect with existing service panel. (2) Inverters: Fronius IG PLUS V 7.5 and IG 4000 NEG. (57) modules: SHARP NU-235F1.****ZERO FEES DUE TO 2012 SENATE BILLNO 1222 ****	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53713	17041-10000-06253	25975 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	PIN	33.78930534	-118.29537445	PC FOR FUEL CELL SYSTEM. INTERCONNECTING TO 2 DIFFERENT SERVICE METERS. THIS IS PROJECT 2/2. SPECIFIC FOR ADDRESS 1050 PACIFIC COAST HIGHWAY. CONTROL SYSTEM AND LOCATION IS SHARED WITH OTHER PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53714	17041-20000-40633	5930 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	08/12/2020 12:00:00 AM	ADDRESS	34.10527	-118.18406	Plan check for power and energy. Project site is a new commercial building. Project scope is a fire-rebuild. Work includes a 2,000-amp service and new distribution equipment. Total lighting area = 1,455 sq. ft.Note: Building application has been generated under 17016-20000-05871	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53715	13041-20000-34020	19771 W BUCKEYE MEADOW LANE	91326	12	213B113   226	2701029024	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.28087	-118.56665	PV1 LF TRANSFORMER WITH MICROINVERTER. TOTAL SYSTEM SIZE 7.2KW. 30 PANELS 1 INVERTER AND 4 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53716	17041-10000-29753	4205 S ZAMORA ST	90011	9	114A211   151	5115028024	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.10	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.00728	-118.25306	PC FOR PV SYSTEM RATED 3.8 KW AC USING 12 MODULES. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53717	14041-10001-02558	1001 N VERMONT AVE	90029	13	144B197   961	5538022021	[Q]C2-2D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM			PC Approved	03/13/2015 12:00:00 AM	ADDRESS	34.08964	-118.29193	CHANGES TO AN APPROVED SET OF PLANS.  ADDING (8) CONDENSING UNITS.  CHANGES MARKED DELTA FOUR ON FLOOR PLANS.PLAN CHECK FOR POWER AND ENERGY. TI FOR MARKET ON FIRST FLOOR AND RESTAURANT ON SECOND FLOOR. UPGRADING EXISTING SERVICE WITH NEW 800A, 120/240V, 3PH, 4WIRE UNDERGROUND SERVICE. NOT LOCATED IN METHANE ZONE. PROJECTED AREA IN LIGHTING WORK IS APPROX. 13538 SQ FT ( 8118 INDOOR, 5420 OUTDOOR) . NOTE: THIS PLAN WILL BE SUBJECTED TO 2011 NEC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53718	12041-20000-14572	11301 W PICO BLVD 109	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM			PC Approved	06/22/2012 12:00:00 AM	ADDRESS	34.03517	-118.43924	"T.I. to existing retail space inside ""BEST BUY"".  Install general/emergency lighting.  Plan check for energy only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53719	14041-20001-33312	1905 W 9TH ST	90732	15	015B189   240	7560026027	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	33.73656	-118.31835	1/9/2015 - Modification to approved set. Change the location of the inverter from an exterior wall to the inside of the garage only. PV disconnect shall be lockable. Delta 1 changes. [pv1install roof mounted pv system sized 3.8kw interconnected with msp.(17) canadian solar cs6p-250p modules(1) solar edge se3800 transformerless inverter]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53720	18041-10000-45101	7716 N CLYBOURN AVE	91352	2	189B177   821	2466030023	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.21097	-118.36339	PLAN CHECK FOR POWER AND ENERGY FOR SERVICE UPGRADE TO 800A 120/240V WITH ASSOCIATED EQUIPMENT AND CONNECTION OF EXISTING LOADS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53721	16041-10000-25130	15579 W MEADOWGATE ROAD	91436	5	165B141   244	2285003046	R1-1	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.14953	-118.47409	PV1, rooftop solar installation on SFD, 12.75 kW AC.(51) LG 320 N1C(51) Enphase M250(1) Load center	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53722	14041-10000-14576	2866 W 7TH ST	90005	1	133-5A201 181	5077015008	C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.05967	-118.28596	PV2, INSTALL 12 KW DC ROF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING, PV2 10.368KWAC. 240V. microinverter. NONstd. 2story. Roofmount. [(1) inverters: {0}]. [(48)modules: {Canadian Solar {CS6P 250P}}]     UPGRADING MAIN SERVICE PANEL TO 225 A SERVICE. MICRO INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53723	13041-10000-35138	7211 N WINNETKA AVE	91306	3	183B113    24	2114019009	C4-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.20145	-118.57119	"T24 PART 6 ENERGY FOR (E)  1210 SQ FT COMMERCIAL SPACE (""EL POLLO LOCO"" ).  (E) 600A SWITCHBOARD. SCOPE OF WORK < 400A. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53724	13041-20001-23194	9301 N TAMPA AVE # 67	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	(((2/25/2014- CHANGES MADE TO APPROVED SET OF PLANS. PLAN CHECK FOR ENERGY ONLY.)))) TI retail space in mall.  Power and energyNote: this should be Title 24 only plan check-remodeling existing retail store ;added power load is less than 100A; CONDUCTORS, PANELBOARDS AND MAIN SWITCH ARE EXISTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53725	18041-10001-18463	4501 W COLORADO BLVD	90039	13	162B205    19	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.14246	-118.2705	[This is plan check only, permit is covered under master # 18041-10000-18463]  Revision to approved set, plan check for T24 only, install lighing on two storage room. Total area under the scope revised from 70.5 sq.ft to be 171 sq.ft, also adding one light.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53726	11041-10000-15364	1614 W WILSHIRE BLVD STORE# 1	90017	1	132A205   217	5142012005	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.05542	-118.27078	TI TO AN EXISTING RETAIL SPACE.  SPACE WILL BE FOR FURNITURE/LAMP RETAIL.  PLAN CHECK IS FOR ENERGY ONLY.  ((((((((TWO SEPERATE APPLICATIONS WILL BE ASSIGNED TO THIS SINGLE PLAN FOR TWO SEPERATE STORES.  THIS PLAN CHECK IS FOR STORE #1))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53727	18041-10000-15836	4018 S MICHAEL AVE	90066	11	108B153   392	4230017007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	33.9936	-118.44013	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER WITH POWER OPTIMIZERS. (11) MODULES WITH OPTIMIZERS AND (1) INVERTER, 3.0KW. TOTAL SYSTEM SIZE IS 3.0KWAC AND 3.025KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53728	16041-30000-01383	3650 W MARTIN LUTHER KING, JR BLVD 113	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	Title 24 plan check only.  Total area = 2,940 sq. ft.   T.I. to existing commercial retail space.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53729	18041-20000-40728	956 N CORSICA DR	90272	11	126B133    21	4408010007	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.04524	-118.50808	PV1.  Install roof mounted PV system sized 15.2kW AC interconnected with MSP.$6.77 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53730	16041-10002-45568	685 S CATALINA ST	90005	10	132B197   147	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			10/17/2019 12:00:00 AM			Reviewed by Supervisor	10/29/2019 12:00:00 AM	ADDRESS	34.06047	-118.29555	PC FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES RELOCATING LOADS, UPDATING LOAD CALCULATIONS, VOLTAGE DROP CALCULTIONS, REMOVING EQUIPMENT AND UPSIZING A TRANSFORMER. ALL CHANGES ARE CLOUDED UNDER DELTA 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53731	16041-10001-12056	1317 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	33.78944	-118.24737	CHANGES TO APPROVED SET OF PLANS. CHANGE BREAKER RATING AND LAYOUT. ALL CHANGES NOTED DELTA 1 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53732	16041-30000-10024	1146 S WESTWOOD BLVD	90024	5	132B153   246	4363022009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.05998	-118.4446	Title 24 plan check only.  Total area = 821 sq. ft.T.I. to existing restaraunt space.  New lighting and receptacles.  Subpanels to remain existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53733	18041-20000-07071	6150 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Closed	02/27/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	Plan check for power only. Project scope is a 1,600-amp temporary power service and related distribution equipment.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53734	19041-20000-53399	2915 W EXPOSITION PL Unit #1	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM				NEW ROOF MOUNTED 2.56KW PV SYSTEM WITH 8 @ 320W PANELS AND A CENTRAL INVERTERS ON AN APARTMENT BUILDING FOR UNIT #1.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53735	19041-10000-26391	4777 W SANTA MONICA BLVD	90029	13	144B197   714	5540022018	C2-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.09103	-118.29346	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53736	16041-10000-19118	12548 W TERRA BELLA ST	91331	7	207B161    87	2536026009	RS-1	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.26653	-118.40628	PV1 roof mounted solar system installation to a single family home. 24 microinerters solar modules. Total system rated: 5.16 kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53737	17041-10000-02312	1875-1885 W 20TH ST	90007	1	126B197   980	5075029016	R3-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Apartment			02/13/2017 12:00:00 AM			Reviewed by Supervisor	03/13/2017 12:00:00 AM	ADDRESS	34.03826	-118.29968	Full Plan check for power and energy for a new 4 story 18 unit appartment building. Scope includes a new 1200A 120/240 3 phase 4 wire service/distribution board, new panels, and new lights. Total affected area: 21,565 sq ft. b#16010-10000-06451	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53738	15041-10000-11333	9301 N TAMPA AVE # 60	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	09/26/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	REMODEL JEWLRY STORE INSIDE THE NORTHRIDGE FASHION MALLPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53739	19041-20000-07025	7724 N GRAYSTONE DR	91304	12	189B089   366	2017027005	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.21175	-118.65408	NEW 10.2KW DC/10KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD, 34 SILFAB 300W PV MODULES, 34 P320 OPTIMIZERS, AND 1 SE10000H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53740	13041-10001-34486	14161 W SAYRE ST	91342	7	222B153   617	2508013018	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.3028	-118.44221	Expedited RSES plan check per applicant request.{{PV1, Install a 3.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (13) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53741	12041-20000-11687	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Approved	05/21/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin # 173 T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53742	12041-10001-09812	4600 W COLORADO BLVD	90039	13	162B205   273	5593018903	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.14094	-118.27314	REVISIONS TO PERMITTED SET OF PLANS:Sheet  E-8: USE 250KCMIL FEEDERS INSTEAD OF 350KCMIL FEEDERS SUPPLYING 4160V 1500HP MOTORS. FLA for each motor is 185.2A ;feeder ampacity is 280ASheet EE-8: on MCC-B, CHANGE CIRCUIT BREAKERSFOR FEEDERS SUPPLYING LCP  AND FCV MOTOR. skids #3 & #4 Include note # 3 0n sheet O-E-3 FOR EYS SEAL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53743	13041-10000-04796	7801 W BEVERLY BLVD	90036	5	138B177   437	5527038001	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			Corrections Issued	03/04/2013 12:00:00 AM	ADDRESS	34.07628	-118.35956	T24 FOR A MUSIC SCHOOL CHANGE OF USE FROM RETAIL SPACE TO MUSIC SCHOOL.  1665 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53744	12041-10000-24732	17622 W HORACE ST	91344	12	210B129   665	2712013014	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.26958	-118.51835	New 13.4 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53745	18041-10000-15820	20209 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Issued	11/02/2018 12:00:00 AM	ADDRESS	34.27509	-118.57388	FULL PC FOR WHOLE FOODS MARKET BUILDOUT (41,00SF) TO EXISTING CORE AND SHELL RETAIL BUILDING WITH 1 LEVEL MEZZANINE. SCOPE OF WORK INCLUDES NEW CIRCUITS AND PANELS. TOTAL SQ. FT. 42517.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53746	14041-20000-13560	500 N KENTER AVE	90049	11	135B137   189	4494018009	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.06804	-118.48592	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING 3 STRINGS. TRANSFORMERLESS IVNERTER. NONSTANDARD PLAN. 17 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53747	13041-10000-30347	111 S KINGS ROAD	90048	5	138B173   660	5511015010	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			10/30/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.07409	-118.37238	NEW FIRE ALARM SYSTEM IN 20 UNITS 4-STORY APARTMENT BUILDING. BUILDING AREA IS 31,586 SQ FT. BUILDING IS EQUIPPED W/ AUTOMATIC FIRE SPRINKLERE SYSTEM. TOTAL OF 99 DEVICES, 2 PANELS. UNDERGROUND PARKING, 4 STORIES, AND ROOF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53748	09041-10001-05753	177 S MOUNTAIN VIEW AVE	90057	13	135A205   145	5154007002	C2-1	Central	Westlake		YES	2084.01	Electrical	Electrical	Commercial			01/13/2010 12:00:00 AM			PC Approved	01/13/2010 12:00:00 AM	ADDRESS	34.0644	-118.27118	Change motors from 3 phase to single phase, change feed for the elevator and revise the location of occupancy sensor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53749	18041-10000-24937	3801 S BROADWAY PL	90037	9	117A203   240	5122039036	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.0136	-118.27616	NEW WAREHOUSE. 600 AMP SERVICE. 49,796 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53750	18041-10000-22192	4155 W RUSSELL AVE	90027	4	150B201  1105	5591022901	R2-1XL	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.1046	-118.28028	**SEE APPLICATION NOTES****PC FOR  SERVICE UPGRADE 1600A 3PH 120/208 FOR EXISITIGN SCHOOL.SCOPE INCLUDES NEW SERVICE EQUIPMENT AND PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53751	17041-30000-10258	17147 W BURTON ST	91325	6	192B133   536	2204001050	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Issued	03/30/2017 12:00:00 AM	ADDRESS	34.22028	-118.50727	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53752	12041-10000-26403	17351 W SUNSET BLVD	90272	11	126B117   567	4416003034	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	Apartment			11/02/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.04039	-118.5542	"NEW FIRE ALARM SYSTEM IN AN APARTMENT BULDING.""COMPLY WITH DEPARTMENT ORDER effective date 08/22/2008. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53753	13041-20000-20984	8519 W PICO BLVD	90035	5	132B173  1243	4332028039	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.05369	-118.37695	Tenant improvement to add a new restroom and guardrail to an existing retail (2,422 sf). NEW LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT ISSUED UNDER THIS APPLICATION))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53754	10041-10000-17709	1548-1550 W SLAUSON AVE	90047	8	108B193  1359	6002003019	[Q]CM-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM			PC Approved	09/08/2010 12:00:00 AM	ADDRESS	33.98894	-118.30418	2-STORIES mIXED USED : OFFICE OVER RETAILPLAN CHK IS FOR TITLE 24  ;PERMIT WAS OBTAINED ON 10041-10000-01730	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53755	13041-10000-21052	708 N LA CIENEGA BLVD 2ND FLOOR	90069	5	141B173   431	5528001059	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.08395	-118.37636	TITLE 24 PLAN CHECK ONLY. OFFICE BUILDING. 2 STORIES. WORK ON FIRST FLOOR AND PRIVATE STAIR. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53756	16041-10000-39067	950 E 3RD ST	90013	14	127-5A217  91	5163016016	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			11/03/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	Installation of a new fire alarm system for a new 7 story joint live and work quarters over a commercial use garage structure.  Total system size = 1,560 FA devices + 8 FA panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53757	15041-10000-11201	10440 N ORO VISTA AVE	91040	7	204B189    85	2560007022	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Expired	05/09/2017 12:00:00 AM	ADDRESS	34.2591	-118.31562	RETROFIT OF 16 EXISTING LIGHTS TO LED WITH RETROFITS KITS. TITLE 24,  PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53758	17041-10000-34706	3201 S HOOVER ST STE 1870	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	PC FOR FIRST TIME TENANT FOR A RESTAURANT (THE VILLAGE AT USC) FOR POWER AND ENERGY.SCOPE INCLUDES NEW PANELS, CIRCUITS AND EQUIPMENT.TOTAL AFFECTED AREA  2290 SQ.FT (INDOOR).B#17016-10000-13980	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53759	15041-10002-06714	1836 N DOHENY DR	90069	4	150B169  1192	5561008043	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.10553	-118.3879	Change to approved set.  Change to upgraded MSP ratings.  $0 PLAN CHECK FEE IS DUE TO STATE SENATE BILL SB-1222. (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.7KW INTERCONNECTED WITH MSP.(51) CANADIAN SOLAR 260W MODULES(2) SUNNY BOY TL INVERTERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53760	15041-10000-23492	6817 W FRANKLIN AVE	90068	4	150A185   287	5549018024	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	PIN	34.10444099	-118.33917245	SERVICE UPGRADE TO 1200 AMPS.  RECONNECT EXISTING LOADS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53761	11041-20000-26397	8332-8334 S OSAGE AVE	90045	11	096B173    52	4127024002	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	33.96253	-118.3786	T24 Energy plan check for auto body shop. Permit for new light fixtures on exiting branch ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53762	12041-20000-03096	19128 W CASTLEBAY LANE	91326	12	219B121   261	2820010015	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2012 12:00:00 AM			Corrections Issued	03/23/2012 12:00:00 AM	ADDRESS	34.29436	-118.54999	New roof mounted 7.68KW PV system with microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53763	15041-10000-23880	2114 S SAWTELLE BLVD STE 211	90025	11	126B153   894	4260001031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			Not Ready to Issue	08/05/2015 12:00:00 AM	ADDRESS	34.03909	-118.44181	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO A NEW PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG. TOTAL SQUARE FOOTAGE 909.  SCOPE OF WORK IN SUITE NUMBER 211	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53764	15041-10000-30820	1803 W 29TH ST	90018	8	123B193  1166	5053026026	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.02924	-118.30336	PV1, INSTALL 5.565 KW DC ROOF-MOUNTED ROOF-MOUNTED ON  A SINGLE FAMILY HOUSE.(21) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53765	19041-20000-53181	836 W 42ND PL	90037	9	114B197   922	5019006016	R3-1	South Los Angeles	South Los Angeles	Voices		2317.10	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM	05/29/2024 12:00:00 AM		Issued	05/29/2024 12:00:00 AM	ADDRESS	34.00631	-118.28855	PC FOR INSTALLATION OF 1200 AMP 120/208 V 3P 4W SERVICE FEEDING A MIXED USE BUILDING. SCOPE IS DISTRIBUTION BOARDS, PANELS, ELEVATOR MOTOR, EV CHARGERS, UPS, UNIT PANELS, LIGHTING AND LIGHTING CONTROLS.***********************************************************************************PER BUILDING# 19010-10000-01996: NEW 31 UNIT 4 STORY TYPE VA  APARTMENT BUILDING OVER 1 STORY TYPE 1A  ON-GRADE GARAGE. 1 Extremely low income unit and 4 Very low income unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53766	19041-20000-29301	7933 W WENTWORTH ST	91040	7	208-5A195  39	2552017033	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.26708	-118.30592	PV1.  Install 8.58 kW DC / 7.902 kW AC roof mounted grid tied PV system.  (26) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53767	12041-10000-10507	10701 W PICO BLVD	90064	5	126B157   691	4320005064	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	ADDRESS	34.04183	-118.42538	INTERIOR REMODELING OF AN EXISTING CHASE BANK.CUSTOMER REQUESTED FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53768	16041-10000-02111	5603 S CENTRAL AVE	90011	9	108B209  1119	5103016030	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	33.99131	-118.2567	NEW RETAIL BUILDING TO BE SUBDIVIDED INTO 6 EA TENANT SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53769	14041-20002-19844	455 S LORRAINE BLVD	90020	4	135B189   602	5504003011	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM			PC Approved	08/26/2014 12:00:00 AM	ADDRESS	34.06565	-118.32015	$0 PLAN CHECK FEE DUE TO SENATE BILL 1222 FROM 2012CHANGES TO APPROVED SET OF PLANS. CHANGE IN MODULE LOCATION. PC FOR SITE PLAN AND SINGLE LINE CHANGES. NO PERMIT TO BE ISSUED FORM THIS APPLICATION. PLAN CEHCK ONLYOriginal permit issued under permit number #14041-20000-19844	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53770	12041-10000-02091	1615 N VINE ST	90028	13	148-5A187 258	5546009400	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM			Corrections Issued	02/05/2012 12:00:00 AM	ADDRESS	34.10036	-118.32687	existing theater, two services, new panel, ckts and title 24 and emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53771	16041-10000-10396	3825 N MISSION ROAD	90031	1	136-5A227  10	5211011030	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.07009	-118.19958	SECOND FLOOR ADDITION <<1,916SF> TO EXISTING CHARTER SCHOOLnew lighting. pc for t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53772	19041-10000-03880	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.08469	-118.4849	This is plan check for Power only, scope includes: Replacing a 450A service breaker to 600 Amp in an existing 600A service, Installing new HVAC system, new 75KVA transformer and new phase converter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53773	14041-20000-01734	24221 W HILLHURST DR	91307	12	186B089   638	2027043024	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.20317	-118.65195	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5KWAC. 3 STRINGS 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53774	13041-20000-12769	13928 W MORRISON ST	91423	2	168B153    72	2269014005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.16047	-118.43613	PV1 SINGLE FAMILY DWELLING. USING ENPHASE MICROINVERTER STANDARD PLAN. TOTAL SIZE 3.4KW. USING 16 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53775	19041-10000-24581	13469 W TERRA BELLA ST	91331	7	204B157  1104	2646016015	R1-1	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.25258	-118.42649	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 MODULES (Q-PEAKG4.1 305), 20 OPTIMIZERS (SE P320) AND A CENTRAL INVERTER (SE6000H-US). SYSTEM SIZE IS 6.10KWdc AND 6KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53776	14041-10000-34648	1073 S BROXTON AVE	90024	5	132B149    72	4363024003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.06118	-118.44618	plan check for energy 2013 Standards. TENANT IMPROVEMENT PROJECT OF A RESTAURANT IN AN RETAIL SPACE.  CAVAGRILL WILL OCCUPY 2,000 SF. BLDG#14016-10-25298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53777	16041-10002-35144	9350 N DE SOTO AVE	91311	12	198B109    80	2748002071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM			PC Approved	05/10/2017 12:00:00 AM	ADDRESS	34.2406	-118.58834	REVISION TO THE APPROVED SET OF PLAN INCLUDING ADDITON OF AC DISCONNECT TO THE INVERTERS TO PROVIDE THE SHUT DOWN FOR EACH INVERTR AND  TWO 6-POLE DISCONNECT TO SHUT DOWN THE 2 CARPORTS  (5/10/2017)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53778	13041-10000-20962	8427 N OUTLAND VIEW DR	91352	2	192B177   326	2404015046	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	34.22361	-118.35701	PV1 2.808KW 240V MICROINV 1STORY. nonSTD. ROOFMOUNT.[( 13) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: talesun tp660P 240w]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53779	12041-10000-16485	8121 W MULHOLLAND TER	90046	2	156B173   323	2381029004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.12381	-118.37668	Plan check for new roof mounted 5.04KW photovoltaic system (SolarEdge transformerless inverter) using solar DC-DC powerbox. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53780	19041-20000-53199	1546 S ORANGE GROVE AVE	90019	10	129B177  1106	5068026015	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM			PC Info Complete	08/03/2020 12:00:00 AM	ADDRESS	34.04816	-118.36621	INSTALL NEW 1600 AMP 208V SERVICE, (32) PANELS WITH EQUIPMENTS AND LIGHTING LOADS. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 29198 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53781	15041-10000-14552	8448 S LINCOLN BLVD	90045	11	096B157   278	4113014035	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	05/14/2018 12:00:00 AM	ADDRESS	33.96096	-118.42001	Full plan check per applicant request for a super market (Bristol Farms) remodel. Scope includes relocating panels and installing new lighting, equipment  and receptacle outlet.  Note. plan checker verify additional fee for key note #4 on panel schedule sheets.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53782	15041-10000-18093	639 N BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM			PC Info Complete	06/15/2015 12:00:00 AM	PIN	34.05985996	-118.23998637	TI TO AN EXISTING SINGLE STORY COMMERCIAL BLD. ADDING NEW LIGHTING, CONTROL TO A NEW PANEL, NEWLY CONNECT A LOAD <400 A, PLAN CHECK FOR ENERGY AND EMERGENCY PLANNING ONLY. TOTAL SQ.FT: 1387.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53783	15041-10000-37543	11936 N RICASOLI WAY	91326	12	216B109    55	2701078001	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.28981	-118.58467	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(20) SUNPOWER SPR-X20-250 MODULES(1) SUNNYBOY SB5000 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53784	19041-20000-06868	8700 S PERSHING DR PV3	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	33.95471	-118.44097	PV2.  Install 22.27 kW DC / 20.34 kW AC roof mounted grid tied PV system.  (61) modules with (1) 20 kW rated string inverter.  Interconnecting with MSA-3.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53785	14041-20000-24862	13848 W CUMPSTON ST	91401	4	174B153  1249	2247013062	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.16933	-118.435	pv1 sfd. using standard plan central inverter system. using 24 modules, 7.5 kw invterter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53786	10041-10000-12431	10250 W SANTA MONICA BLVD 114	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	REMODELING OF RETAIL STORE AT THE CENTURY CITY MALLPLAN CHK IS FO RTITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53787	16041-10000-41220	1950 W SLAUSON AVE	90047	8	108B193  1519	6001001022	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.98884	-118.31277	PC FOR T24 ENERGY ONLY. LIGHTING FIXTURE REPLACEMENT IN PARKING LOT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53788	18041-10000-14320	879 W 190TH ST 500	90248	15	060B197   499	6121021008	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Info Complete	04/19/2018 12:00:00 AM	ADDRESS	33.85951	-118.28963	PC FOR OFFICE TI ON THE 5TH FLOOR IN A HIGH RISE  COMMERCIAL OFFICE .SCOPE OF WORK INCLUDES NEW CIRCUITS, LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 3944 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53789	08041-10001-18612	1633 N SAN PABLO ST	90033	14	135A225    12	5201004003	CM-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.06502	-118.2025	T24 FOR OPEN PARKING.ORIGINAL SET WAS LOST, ONLY A COPY AVAILABLE. NO CHANGE IN P DESIGN, SAME ENGINEER SIGNED THE ORIGINSL AND CURRENT SET.<<Permit is for outdoor lighting (new lighting poles <30') for a parking lot.  P/C is for Energy only.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53790	16041-10000-17130	3377 W WILSHIRE BLVD #104	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.06193	-118.29742	T-24, PC FOR ENERGY ONLY.  TI FOR A SMOKEHOUSE BBQ RESTAURANT. TOTAL AFFECTED AREA IS 2422 SQ. FT. B# 16016-10000-09705,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53791	19041-20000-20182	537 S BROADWAY 400	90013	14	129A211   120	5149033003	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.04731	-118.25166	T24 plan check for lights only in suites 400 for existing high rise office. Total square footage = 3190sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53792	15041-20001-10592	3479 N CAHUENGA BLVD	90068	4	159B177   338	2425024028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.13249	-118.35498	[[[6/19/15 CHANGES TO APPROVED SET OF PLANS. ADDITION OF 50 NEW LED FIXTURES. ]]]]Plan check for Title 24 only. Project site is an existing commercial space (existing hair salon). Project scope is a tenant improvement. Total lighting area = 1,746 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53793	19041-20000-53164	3614 N AMESBURY ROAD	90027	4	154-5A203 312	5592009039	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Expired	09/20/2023 12:00:00 AM	ADDRESS	34.11615	-118.2798	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER WITH OPTIMIZERS INTERCONNECTED TO ENERGY STORAGE SYSTEM. (1) 3.8 KW INVERTER, (2) 5.8KVA ESS . TOTAL SYSTEM SIZE IS 3.78KWDC/ 3.8KWAC, ESS TOTAL SIZE 27KWH, 11.6KVA.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53794	15041-10000-03490	4000 W 6TH ST	90005	10	135B193   892	5503032006	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	PIN	34.06331902	-118.31071092	Title 24 plan check only.  Total area = 1,085 sq. ft. (820 indoor & 265 outdoor hardscape)Installation of new lighting in new addition to gas station building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53795	19041-10000-03693	18981 W VENTURA BLVD	91356	3	174B121   401	2163020020	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.17265	-118.5472	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53796	14041-30002-34558	5100 W WILSHIRE BLVD 1-138	90036	4	132B181    39	5507026001	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			05/24/2018 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.06187	-118.34094	Change to approved set by adding new load on roof floor, new ATS and new generator. All changes under delta-5 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53797	10041-10000-22216	215 N LARCHMONT BLVD A-C	90004	4	138B189   604	5515018015	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM			PC Approved	11/05/2010 12:00:00 AM	ADDRESS	34.07516	-118.32394	TI in an existing beauty salo plan chk is for title 24; permit was obtained on 10041-10000-20410	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53798	15041-20000-07863	7202 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.24844	-118.28882	Plan check for power and Title-24 (energy).  Total area = 1,639 sq. ft.T.I. to first time tenant nail salon.  3 new panels.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53799	10041-10000-03181	3410 S LA CIENEGA BLVD	90016	10	120B173   310	5047018901	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Public Safety Only			02/23/2010 12:00:00 AM	02/23/2010 12:00:00 AM		Permit Closed	02/22/2011 12:00:00 AM	ADDRESS	34.02602	-118.3719	Plan check for new installation of fire alarm system in a LA City Air Treatment Facility	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53800	18041-10000-26945	4820 W FOUNTAIN AVE	90029	13	147B197  1142	5540015021	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.09522	-118.29408	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53801	15041-20000-41252	5611 N FIGUEROA ST	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.10937	-118.19392	Plan check for Core and shell in existing space power and energy. Service upgrade 1600A. Total area: 2115 sqft.Note: Building permit # 15016-10000-13162	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53802	12041-20000-03649	21801 W OXNARD ST	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13, 1351.14	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.17941	-118.60306	Full plan check for remodel of a portion of a  (E) MOVIE THEATER - DEMO & REMODEL 3-CONCESSION STANDS, SEAT CUSHION REPLACEMENTS; BOX OFFICE FINISHES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53803	17041-20001-01594	5365 N VANALDEN AVE	91356	3	171B121   618	2163011028	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.16865	-118.55032	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.24 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53804	11041-20000-02382	126 N GLENDALE BLVD	90026	1	135A209   387	5160013005	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.06266	-118.25957	PLAN CHECK POWER AND ENERGY FOR REMODEL OF (E) COMMERCIAL KITCHEN WITH NEW 600A SERVICE, EQUIPMENT, AND CKTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53805	17041-20001-46142	18951 W KINBRACE ST	91326	12	219B121    69	2820003032	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2017 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.29652	-118.54708	Expedited plan check fee.PV1.  Install 5.1 kW roof mounted grid tied PV system.  (18) modules with 5 kW rated string inverter.  Center-fed panel connection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53806	17041-20001-42970	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	34.23541	-118.47521	expeditepv2install roof mounted pv system sized 46.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53807	19041-20000-39354	3200-3210 S GRAND AVE	90007	9	120A203   247	5122008002	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.0215	-118.27525	Power, lighting, and distribution for change of use from retail/office to F-1 agricultural.  Plan check for energy only - connected load less than 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53808	14041-20000-29984	1426 N FULLER AVE	90046	4	147B181   824	5548019011	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			10/29/2014 12:00:00 AM			PC Info Complete	07/02/2015 12:00:00 AM	ADDRESS	34.09671	-118.34942	plancheck for power and energy for 8 units apartment building. 4 stories, variance for fire alarm on hand	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53809	13041-10000-33874	5335 E VALLEY BLVD	90032	14	139-5A237  91	5220033006	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Expired	12/30/2015 12:00:00 AM	ADDRESS	34.07475	-118.16696	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURE. 3000 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53810	17041-20000-05743	60 N BEVERLY PARK	90210	4	156B161    81	4386013013	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Expired	12/18/2021 12:00:00 AM	ADDRESS	34.12101	-118.4164	Plan check for power only. Project site is an existing SFD. Project scope is a service upgrade and refeeding certain distribution equipment.Note: Building permit has been issued under 15016-20000-10640	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53811	16041-10000-39731	906 S CRENSHAW BLVD	90019	4	132B189   914	5092003027	CR-1VL	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.05608	-118.32204	PV SYSTEM ROOFTOP COMMERCIAL. PC FOR 4.5KW WITH 18 MODULES IN TOTAL.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53812	17041-10000-01962	1725 N ARGYLE AVE	90028	13	148-5A189  68	5546030002	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM			Reviewed by Supervisor	01/30/2017 12:00:00 AM	ADDRESS	34.10252	-118.32534	NEW SINGLE STORY STORAGE AND LOADING DOCK BLDG WITH BASEMENTPC FOR POWER AND ENERGY. SERVICE RATED AT 600A (277/480V  3PHASE)TOTAL AFFECTED AREA OF 7332 SQ.FT.Bld App# 16010-10000-06281	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53813	13041-20000-30112	18020 W GAUGUIN ST	91344	12	219B129   333	2601024059	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	PIN	34.2969093	-118.52322386	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 10KWAC. 39 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53814	14041-10000-27769	1101-1145 S WESTWOOD BLVD Panera-Bread	90024	5	132B149    94	4363023029	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.06046	-118.44567	CONVERT (E) OFFICE TO A PANERA RESTAURANT,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53815	10041-20000-12428	300 S GRAND AVE #3920-3950	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM			PC Approved	06/29/2010 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check T-24 Energy office general/emergency lighting spaces on the 39th Floor (suite #3920 & 3950).  All lighting fixtures are existing. Work consist of relocating fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53816	14041-20001-34490	5121 N COLBATH AVE	91423	4	171B153   579	2269007014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	34.16367	-118.43668	EXPEDITED PER APPLICANTS REQUEST.PV1 SFD. TOTAL SYSTEM SIZE 7.115KW AC USING CENTRAL TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53817	16041-10000-32135	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for 1st time tenant, a restaurant within Nordstrom area.  Title 24 (energy compliance forms) has ben covered under the approved master plan for Nordtsrom full store area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53818	12041-10000-29909	415 E ADAMS BLVD	90011	9	120A207   161	5127011033	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Apartment			12/12/2012 12:00:00 AM			Reviewed by Supervisor	12/26/2012 12:00:00 AM	ADDRESS	34.02335	-118.26491	PV2: Plan check 36.6KW roof mounted photovoltaic system for apartment building.  Plans were previously approved under 12041-10000-04367 using different modules and different inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53819	18041-20001-16245	1110 W 48TH ST	90037	9	111B197   823	5017021010	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2018 12:00:00 AM			PC Approved	05/07/2018 12:00:00 AM	ADDRESS	33.99949	-118.2943	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (18) modules, (1) load center, and (1) auto-transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53820	13041-10000-27464	1621 N SOTO ST	90033	14	135A227    22	5202001002	PF-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.06279	-118.19812	MONUMENT SIGN #1- NORTHWEST CORNER OF ALCAZAR/SOTO.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53821	13041-10001-13867	824 S FRANCISCO ST	90017	14	129A207   124	5144022035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.04795	-118.26326	Delta-4 changes to approved set.  Change of location of panels and emergency generator.  Minor load additions (additional receptacles) to existing panel schedule.  (((T.I. to existing parking structure.  Install new 600A service, new switchboard, 25KW generator, and parking light.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53822	11041-20000-16208	1224 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/08/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.02523	-118.2924	"New 3.23 Kw Pv solar equipment ( max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) system for an apartment Bldg"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53823	18041-10001-11208	6523 W HOLLYWOOD BLVD SUIT 3	90028	13	148-5A187 109	5547007012	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	34.10175	-118.33175	DELTA 1 CHANGES TO THE APPROVED PLANS. PLAN CHECK ONLY.<<<<FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO NEW RESTAURANT. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. A-OCCUPANT LOAD > 100. TOTAL AFFECTED AREA IS 2951 SQ. FT. B#17016-10000-06324>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53824	17041-10000-21255	1000 S LAWRENCE ST	90021	14	123A215    50	5166030007	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.03091	-118.23653	T24 ONLY - REPLACEMENT OF EXISTING LIGHT FIXTURES WITH (32) LED FIXTURES.  TOTAL AFFECTED AREA =   20050 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53825	15041-20001-28632	11062 N WINNETKA AVE	91311	12	210B113    69	2708021009	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.27121	-118.56932	Expedite fees.     Installation of new roof mounted solar PV array.  Total system size = 34.2 kWac.  System consists of 160 Solar World 250 W modules divided into 8 strings connected to 3 Solar Edge SE 11400A inverters.  Existing 600 A MSP to have main breaker derated to 500 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53826	12041-10000-17124	6957 N AMESTOY AVE	91406	12	183B133   588	2230003024	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.19716	-118.50562	PV system for Single family dwelling. 15.696kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53827	12041-10000-04330	8835 W PICO BLVD	90035	5	132B169   830	4332014015	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM			PC Approved	03/02/2012 12:00:00 AM	ADDRESS	34.05509	-118.3845	Plan check for compliance with lighting requirements of T-24 including emergency egress and exit lights. Express permit was previously issued under PCIS 11041-10000-22694.(REWIRE & CHANGE/INSTALL A NEW PANEL. 2 OF 2 W/ #11042-10000-18717.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53828	15041-20001-15530	5881 N HILLVIEW PARK AVE	91401	2	174B157    24	2343020013	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM			PC Approved	06/05/2015 12:00:00 AM	ADDRESS	34.17734	-118.42678	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 10.8 kWac.  Central inverter system with 3 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53829	16041-20000-15102	12622 N AMBOY AVE	91342	7	219B145    48	2604015020	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.3006	-118.47168	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSMTEM SIZE: 9.52 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53830	15041-10000-03220	915 S TOWNE AVE	90021	14	124-5A211 147	5132002037	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM			Reviewed by Supervisor	03/05/2015 12:00:00 AM	ADDRESS	34.03534	-118.24896	New 4-story commercial building core and shell with retail spaces including storage and office on the ground and 2nd Floor, office and parking on the third floor.  Rooftop parking with (2) Mechanical Rooms and (1) office space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53831	14041-10001-17190	540 S KINGSLEY DR	90020	10	135B193   794	5503024004	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			09/28/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	ADDRESS	34.06422	-118.30266	(9/28/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGING FEEDERS FROM COPPER TO ALUMINUM.  THIS IS PLAN CHECK ONLY. Plan check for power and lighting. New 35 unit apartment building. New electrical service, new diesel generator,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53832	14041-20001-21435	19941 W LORNE ST	91306	3	189B113   179	2106026012	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM			PC Approved	08/13/2014 12:00:00 AM	ADDRESS	34.2173	-118.56811	Modifications to approved set.  Upgrade of MSP from 125A bus rating and 100A main OCPD to 200A bus rating and main OCPD.  (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(1) SOLAR EDGE SE6000 TRANSFORMERLESS INVERTER(33) TRINA SOLAR TSM255 MODULES(33) SOLAR EDGE OPTIMIZER P300)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53833	19041-20001-30976	5457 N LEMONA AVE	91411	4	174B145   718	2250013028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	34.17014	-118.45982	08-29-2019 Changes to an approved set of plan, Changes include relocate inverter and battery powerwall and addition of load center panel. All Changes has been clouded.Fees $4.63 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53834	19041-20000-28656	11152 N LANGMUIR AVE	91040	7	210B193   263	2551038016	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.27205	-118.30854	addition of (1) ESS rated 5KW to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53835	16041-10002-17687	8274 N SUNLAND BLVD	91352	2	192B173   562	2407024039	[Q]C2-1VL-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.22101	-118.3672	Supplemental PC for lost set of plans for 16041-10001-17687.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53836	16041-20000-05213	307 N WILMINGTON BLVD 4B	90744	15	027B205   209	7417010905	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM			PC Approved	08/29/2016 12:00:00 AM	ADDRESS	33.77243	-118.27378	PLAN CHECK ONLY, Plan check for new appartment building 12 residential buildings, with total of 88 units, include new services, site lighting, community blde. Total area: 2000 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53837	11041-10000-06785	3660 S GRAMERCY PL	90018	8	120B189  1495	5042018031	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.00	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.02143	-118.3137	Ti in an existing church. Adding 2 new panels and circuits. EPC is for energy & emergency lights. (Complete plan check may be required by field inspection)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53838	11041-10000-02370	12230 W OSBORNE PL	91331	7	207B165   247	2537001032	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Apartment			03/03/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.26102	-118.39981	NEW CONSTRUCTION APARTMENT BUILDING WITH 5 UNITS, ADDRESS FOR THIS BUILDING IS 12230 (BUILDING @ 12232 OF PROJECT IS ON A SEPERATE PERMIT).  FULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53839	10041-20000-11403	1901 S AVENUE OF THE STARS 4th Floor	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	08/26/2010 12:00:00 AM	ADDRESS	34.05949	-118.41705	Plan check T-24 Energy (general/emergency) lighting for office spaces TI on 4th floor. All circuits are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53840	14041-20000-12848	14333 W ADDISON ST 1-46	91423	4	171B153   727	2248008039	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			05/14/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.16135	-118.44556	PV2 MULTIFAMILY DWELLING. USING 3 CENTRAL TRANSFORMERLESS INVERTERS. TOTAL SYSTEM RATING 18KW AC. USING TOTAL OF 70 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53841	12041-20005-01921	10643 W SUNSET BLVD Bldg #3	90077	5	138B153   103	4362009012	A1-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.07571	-118.44485	Modification to previously approved set of plans for BLDG #3.        <<<Plan check for new 2000A service and distribution boards. Existing charter school buildings. Consolidating multiple services into one service. No new loads added.  (3 of 3 - Permit 12041-10000-01921 is for building #1,  Permit #12041-10001-01921 is for Building #2 and This Permit #12041-10002-01921 is for Building #3)>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53842	12041-20000-05082	680 W KNOX ST	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	04/18/2012 12:00:00 AM		Permit Finaled	05/16/2012 12:00:00 AM	ADDRESS	33.85408	-118.28767	Additional of 800 Amp subpanel.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53843	13041-20000-13664	7300 W HOLLYWOOD BLVD	90046	4	147B181   182	5550016024	[Q]R5-1	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Info Complete	05/28/2013 12:00:00 AM	ADDRESS	34.10144	-118.34913	NEW 1200A SERVICE. PC FOR NEW SERVICE ONLY. FUTURE EXPANSION NOT IN CONTRACT.  FUTURE TENANTS WILL REQUIRE FULL PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53844	13041-20000-29385	6600 N TOPANGA CANYON BLVD #9028	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	churro stix at topanga mall kiosk	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53845	19041-20000-53140	2025 S PACIFIC AVE	90291	11	106-5A145 394	4226013016	[T][Q]C1.5-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	33.98512	-118.47027	T-24, PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE LOADS. TOTAL SQ. FT. 3162.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53846	15041-20005-02760	6530 N SEPULVEDA BLVD	91411	6	180B145   491	2235002005	R1-1, R4-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Apartment			04/18/2018 12:00:00 AM			PC Approved	04/18/2018 12:00:00 AM	ADDRESS	34.18936	-118.46595	04/18/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta F. Indicated feeder lengths and sizes have been revised.04-05-2018. Changes to an permitted set of plan. Changes include Service entrance conductor from Copper to Aluminum and from 2 Service entrance to 1 service entrance conductor, reconfigured meter bank in the electrical room single line diagram. Changes apply to delta E only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53847	12041-10001-06008	3900 N STANSBURY AVE	91423	4	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1417.00	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			PC Approved	03/20/2013 12:00:00 AM	ADDRESS	34.14084	-118.44264	revised permitted set of plansNew 2-story private school.  Plan check for Power and Energy.  622A of load.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53848	12041-20000-23399	10462 N MARKLEIN AVE	91345	7	207B145   655	2649016022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.26092	-118.47016	Plan check for PV System for a SFD. 4.41 kW DC. TRANSFORMERLESS INVERTER (UNGROUNDED ARRAY)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53849	13041-10000-26407	11755 W WILSHIRE BLVD 8TH -9TH	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	PIN	34.04869377	-118.46238681	TITLE 24 PLAN CHECK ONLY. HIGH RISE. WORK ON 8TH AND 9TH FLOOR. 28,581 SQFT. EMERGENCY LIGHTING.  PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53850	16041-10000-45560	2005-2011 S HOOPER AVE	90011	9	118-5A213  36	5119031027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Info Complete	01/10/2017 12:00:00 AM	ADDRESS	34.02037	-118.24693	PC FOR ENERGY. T.I. REMODELING TI. RETAIL. CONNECTED LOAD =400 A. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR RETAIL SPACE. TOTAL AREA 2720 SQ FT. B#16016-70000-25226Note: permit is pulled under PCIS#16041-10000-45579	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53851	19041-20000-19674	2049 S CENTURY PARK EAST 37TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	T24 PLAN CHECK FOR TI REMODEL OF 37TH FL OF EXISTING OFFICE BUILDING. LIGHTS AND OUTLETS ENERGY ONLY PLAN CHECK. TOTAL SQUARE FOOTAGE= 22,961 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53852	19041-10000-30733	800 E ANAHEIM ST	90744	15	030B209   197	7424011056	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	07/15/2020 12:00:00 AM		Permit Finaled	11/08/2021 12:00:00 AM	PIN	33.78008939	-118.25296777	Plan check for power only, Tenant improvement of (E) warehouse to manufacturing (R&D). Scope of work inlcudes new service upgrade to 480/277V, 1200Amp, 3ph. and new motor loads. Note mehtane zone per zimas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53853	18041-20001-13877	7240 N HAYVENHURST PL	91406	6	186B137   239	2205010905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.20231	-118.49217	05/21/2018 Changes to an approved set of plans. Changes have been made to reflect field installation. Addition of devices has increased to (87).****Previous Work Description*****Plan check for a fire alarm system for an existing commercial building. Scope of work is the replacement of the FACP and the addition of (67) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53854	19041-10000-43394	11480 W GATEWAY BLVD	90064	11	123B153   499	4260036043	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.03308	-118.44166	REMOVE HID FIXTURES AND REPLACE NEW LED FIXTURES -T/24 ONLY INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53855	18041-10000-33752	927 S FEDORA ST	90006	10	132B197   978	5094022034	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			09/04/2018 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	08/26/2021 12:00:00 AM	ADDRESS	34.05511	-118.29774	NEW 32 UNIT 4 STORY APPARTMENT OVER GROUND FLOOR GARAGE/LOBBY AND SUB-TER GARAGE.  SCOPE OF WORK INCLUDES NEW 120/240V, 1600AMP SERVICE WITH 8 TYPICAL ROOM LAYOUTS. TOTAL SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53856	10041-10000-09480	2102 E 1ST ST	90033	14	127-5A223  98	5183008027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2044.20	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.04467	-118.21366	CHANGE OF USE FROM A GYMNASIUM TO A THEATER (CASA 101 THEATER )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53857	17041-10000-22786	1224 S NORTON AVE	90019	10	129B189   828	5081008900	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.04845	-118.32326	TITLE 24 ONLY SCOPE INCLUDES - REMOVE HID FIXTURES(6) AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA (2920SQ. FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53858	16041-20000-13418	3750 W 59TH ST	90043	8	105B185   133	4004013011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	33.98704	-118.3396	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER STANDARD PLAN. SYSTEM SIZE: 3.3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53859	14041-20001-31803	22853 W COVELLO ST	91307	12	186B097   339	2021012022	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.20736	-118.62525	12.23.2014 - Plan check for modifications to approved set. Change panel layout on roof only. Delta 1 changes.[PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING SINGLE TRANSFORMERLESS INVERTER.  NONSTANDARD PLAN. SYSTEM USES POWER OPTIMIZERS.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53860	18041-10003-40482	6600 N TOPANGA CANYON BLVD SPC 49A-&B	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	"DELTA ""8"" CHANGES TO AN APPROVED SET. REVISED FIXTURE SCHEDULE & EMGCY LTS. Original Scope: PLAN CHECK FOR TITLE 24 ONLY. CHANGE OF USE FROM RETAIL TO RETAIL. NEW TENANT SPACE, ALL (E) ELECTRICAL AND SYSTEMS TO BE REMOVED AND NEW ELECTRICAL IS TO BE INSTALLED.building permit #18016-10000-32575*T.I. FOR CONSTRUCTION OF NEW NON LOAD BEARING WALLS; NEW MALL STOREFRONT; NEW FLOORING FINISHES; NEW FURNITURE AND FIXTURES; NEW OD OFFICE EQUIPMENT.*"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53861	19041-20000-16210	9125 S SEPULVEDA BLVD	90045	11	093B165    47	4122024051	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Closed	05/22/2019 12:00:00 AM	ADDRESS	33.95397	-118.39645	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53862	16041-10000-01601	3411-3417 W FLORENCE AVE	90043	8	102B185   784	4006033011	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	33.97469	-118.33127	PC FOR POWER AND T24. NEW  1-STORY  BUILDING INCLUDING 4 RETAIL STORE AND ONE MINI MART. 800A SERVICE. TOTAL AREA 7213 SQ FT(INDOOR AND OUTDOOR).  Fire alarm variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53863	15041-10000-33608	9366 W FLICKER WAY	90069	4	147B165   556	4392006017	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2015 12:00:00 AM			PC Info Complete	12/18/2015 12:00:00 AM	ADDRESS	34.09571	-118.39353	PC FOR POWER. NEW TWO-STORY OVER THE BASEMENT HOUSE. PHASE ONE UNDER THE SCOPE OF THE JOB.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53864	19041-30001-45566	1919 S LINCOLN BLVD	90291	11	108B149   119	4241024028	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	33.9957	-118.45664	PLAN CHECK ONLY FOR T24, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING AND CONTROLS, TOTAL AFFECTED AREA IS 1005 SQFT. NOTE ALL PERMIT FEES ARE PAID UNDER 19041-30000-45566	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53865	19041-20001-24474	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM			Re-Activate Permit	06/02/2020 12:00:00 AM	ADDRESS	34.16935	-118.53104	09-17-2019 Changes to an approved set of plan, changes include change  manufacture to Silent Knight for initiation devices and FACP. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53866	16041-10001-12682	10743 W CUMPSTON ST	91601	2	174B177   896	2416017029	R1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.1701	-118.36511	05/10/16Changes to an approved set of plans. Changes include relocating solar pv modules on the rooflayout, and rearranging the pv equipment on the single line diagram such as the AC disconnect and subpanel. NOTE: Permit paid under the PCIS#16041-10000-12682((((PV2. INSTALL 4.578 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER SPR-327-NE-WHT(1) INVERTER: POWER-ONE PVI-4.2-OUTD-S-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53867	14041-10000-32507	501 S HEWITT ST	90013	14	127-5A215 413	5163023904	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	34.04165	-118.23516	Title-24 plan check only for a public park outdoor lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53868	14041-20000-07628	17336 W INDEX ST	91344	12	210B129    86	2711008022	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.2755	-118.51228	PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS 6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53869	19041-20000-43803	1214 N BEVERLY VIEW DR	90210	5	144B157   189	4357017027	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM			Corrections Issued	11/05/2019 12:00:00 AM	ADDRESS	34.09273	-118.43059	PV1.  Install 11.34 kW roof mounted grid tied PV system.  (36) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53870	14041-10000-32750	833 S SPRING ST	90014	14	127-5A209 206	5144016054	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.04241	-118.25451	PC FOR TITLE 24 ENERGY AND EMERGENCY ONLY. EXISTING COMMERCIAL BUILDING SQUREFOOTAGE 2046,  1717 conditioned and 689 unconditioned.  under ther old code	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53871	19041-20000-46664	1162 N MCFARLAND AVE	90744	15	033B209   371	7425005015	[T][Q]RD2-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	33.78686	-118.25287	PV1.  Install 3.77 kW DC roof mounted grid tied PV system.  (13) modules with 3 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53872	11041-10000-05767	11811 W KIOWA AVE 1-9	90049	11	129B145   548	4265015035	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			03/23/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.04961	-118.46467	FIRE ALRAM SYSTEM FOR 2-STORY 8 UNIT APARTMENT COMPLEX.  OVER THE COUNTER PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53873	19041-20000-34292	12444 W VENICE BLVD	90066	11	111B153   326	4235013027	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/09/2020 12:00:00 AM		Permit Finaled	12/08/2022 12:00:00 AM	ADDRESS	34.0028	-118.43476	PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES NEW 3000 AMPS SERVICE,120/208 3PH, CIRCUITS EQUIPMENTS AND LIGHTING. TOTAL EFFECTED AREA 36,572 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53874	13041-10000-15328	380 WORLD WAY T43-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Info Complete	08/14/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI- BRANCH CIRCUIT & LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53875	12041-10001-23591	4292 S CAMPBELL DR	90066	11	108B157   126	4232014015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	33.99542	-118.42465	PV1 REVISION TO APPROVED PLANS. REVISE PANEL LAYOUT ON ROOF. ROOF-MOUNTED 3.43KW  PHOTOVOLTAIC SYSTEM USING MICRO INVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53876	15041-10000-42292	6600 N TOPANGA CANYON BLVD # 13	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	ALTERATIONS IN RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53877	13041-20002-01005	21650 W OXNARD ST 11TH FLR	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Changes to switching. Inspection per inspector. NO added lights. Optional standby.TI AT OFFICES ON 11TH FLOOR. NON BEARING PARTITIONS, MILLWORK AND SUSPENDED CEILING. CREATE NEW FITNESS AREA FOR TENANT USE ONLY.  22539 SQ.  Plan check for T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53878	18041-10000-41844	333 S HOPE ST 23rd	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	FULL PLAN CHECK FOR POWER AND ENERGY FOR OFFICE T.I. 23rd floor ONLY. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING . TOTAL EFFECTED AREA 21282 SQFT. NEW CONNECTED LOAD OVER 400AMPS.BLD# 18016-10000-35366	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53879	15041-10000-07825	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Expired	04/28/2017 12:00:00 AM	ADDRESS	34.07196	-118.24719	PC FOR ENERGY ONLY. ALTERATION OF EXISTING INDOOR LIGHTING(LEVEL 5 PRESS CORRIDOR LIGHTING) DODGER STADIUM. TOTAL AREA 5116 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53880	11041-10000-12373	621 S WESTERN AVE #201	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	34.0628	-118.30928	CHANGE OF USE FROM RETAIL TO NEW MEDICAL CLINIC OFFICE (DENTIST OFFICE)  1,300 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53881	17041-10000-26383	1414 S GRAND AVE #380	90015	14	124-5A207  83	5134020024	C2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.0367	-118.26549	PC FOR POWER AND ENERGY TO MEDICAL OFFICE  TO CONTAIN EXAM ROOMS, PHYSICIAN OFFICES, BLOOD DRAW, RECEPTION/WAITING AND SUPPORT SPACES (NON HIGH RISE)SCOPE INCLUDES NEW PANEL CIRCUITS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 8016 SQ.FTBldg # 17016-10000-21525	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53882	15041-10001-20833	2522 W 75TH ST	90043	8	102B189  1900	4009015011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	33.97175	-118.32179	(((VOID EXPEDITE)))) EXPEDITR PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2KW INTERCONNECTED WITH MSP.(36) SUNPOWER MODULES(2) POWER-ONE INVERTERS 4.2/6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53883	18041-10002-02653	7681 W WILLOW GLEN ROAD	90046	4	153B173    75	5569001003	RE11-1	South Valley	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2019 12:00:00 AM			PC Approved	06/25/2019 12:00:00 AM	ADDRESS	34.11872	-118.36855	"DELTA ""1"" CHANGES TO APPROVED PLANS.<<<New 8,600 Sqr Ft SFD with 600 amp service,  Building permit is issued under combined 16010-20000-00614.  Permit for the scope under combo permit above.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53884	12041-10000-16671	13411 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15778	-118.4248	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #19	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53885	17041-10000-28954	1320 E 7TH ST SUITE #114	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	PC for T24 only for new lights for retail TI. Total area of 993sqft. building #17016-10000-23551	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53886	17041-10000-39101	1500 S EVERGREEN AVE	90023	14	118-5A223  69	5169004002	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.01966	-118.21519	NEW 154KW  STANDBY GENERATOR TO SUPPLY A  240V 1PH 400A DSTBD AND A 240V 3PH 400A DISTBD EACH THROUGH A 400 ATS SWITCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53887	16041-10001-06768	333 E 1ST ST	90012	14	130-5A215 321	5161012012	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.04991	-118.23994	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED ON PLANS. EMERGECY LIGHTING NOW USING BUG EYE TYPE FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53888	16041-20001-21306	17822 W ERWIN ST	91316	5	177B129    91	2123025037	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.18378	-118.5219	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.38 KW.   AC MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53889	18041-10004-09952	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM			PC Info Complete	01/09/2020 12:00:00 AM	ADDRESS	34.12626	-118.21412	DELTAS 13 & 15 CHANGES ONLY.  ADDITION OF PANELS AND CIRCUITS, CHANGES TO LIGHTING, EMERGENCY PHOTMETRICS & T-24. RELOCATING EQUIPMENT AND RECEPTACLES. NO OTHER CHANGES APPROVED UNDEER THIS SET**********original Scope*********FULL PLAN CHECK FOR THE ANDERSON CENTER AND BIOSCIENCE BUILDING.  SCOPE INCLUDES RENOVATIONS AND ADDITION OF 860 SF OF STORAGE WITH NEW LIGHTING AND EQUIPMENT COVERING A TOTAL TITLE-24 AREA OF 8,000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53890	13041-10000-23491	4816 W FOUNTAIN AVE UNITS 1-60	90029	13	147B197  1139	5540015017	[Q]C4-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			08/28/2013 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.09524	-118.29387	RENOVATION OF A 60 UNIT, 4 FLOORS, RESIDENTIAL BUILDING. REPLACING/ADDING NEW PANELS TO EACH FLOOR. SERVICE SIZE OF 400A. CKTS IN EXISTING PANELS WILL REMAIN EXISTING(JUST PANEL UPGRADE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53891	17041-10000-01223	13847 N TUCKER AVE	91342	7	228B161   152	2582027019	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM	01/13/2017 12:00:00 AM		Issued	01/13/2017 12:00:00 AM	ADDRESS	34.32373	-118.40612	PV, INSTALLATION OF NEW 4.77 KW DC/ 4.55535 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(18) MODULES: AXITEC AXIPOWER AC-265P/1156-605(1) INVERTER: FRONIUS PRIMO 5.0-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53892	14041-10000-17195	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.27455	-118.56289	Plan check for power and lighting.  Total area = 126,234 sq. ft. conditioned, 54,763 sq. ft. outdoor.Service, pannels, lighting, for new church.  Place of assembly. Future eqwuipment: (A/V equipment) .PLAN CHK IS FOR CORE AND SHELL; PLANS SHALL BE SUBMITTED FOR NEW CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53893	19041-10000-18954	736 W 130TH ST	90247	15	081B197   455	6117025006	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	33.91425	-118.2883	pc for pv-1 system. system size is 7,360kw. 23 hanwha q-cell modules w solaredge optimizers, 1 se5000 solaredge inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53894	10041-20000-11753	9301 N TAMPA AVE S.04	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.2392	-118.55379	FOREVER 21 T.I.( CHECK IS PRECUT, NO T-24 FEES INCLUDED ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53895	19041-20000-20322	100 N WOODBURN DR	90049	11	135B145    22	4429028039	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Issued	05/29/2019 12:00:00 AM	ADDRESS	34.07001	-118.4699	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM. SYSTEM SIZE IS 21.9KW DC/15.2KW AC. SCOPE OF WORK INCLUDES (60) LG ELECTRONICS PV MODULES WITH SOLAR EDGE P320 OPTIMIZERS, A 100A LOAD CENTER, AND (2) SE7600H-US INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53896	13041-10000-31120	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	PLAN CHECK FOR POWER AND ENERGY. LAX TERMINAL 5 RESTROOM UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53897	18041-10000-08087	1000 W VIN SCULLY AVE	90026	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	PIN	34.07114879	-118.24664847	CLUBHOUSE EXTENSION T.I. - INTERIOR REMODEL RECOVERY ROOM, X-RAY ROOM & QUIET ROOM.PLAN CHECK IS FOR TITLE 24Approved per Francis Ysaguirre	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53898	15041-10000-19681	7900 N SEPULVEDA BLVD	91405	6	189B145   465	2209032042	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.21386	-118.46596	NEW FA SYSTEM FOR A COMMERCIAL SYS. WITH 30 DEVICES AND ONE FA AND ONE COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53899	14041-20000-17625	772 S CERES AVE	90021	14	124-5A213 497	5146003035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.03617	-118.24471	New industrial building.  New 400A service, panels, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53900	16041-20001-22645	8907 N DE SOTO AVE #8907	91304	3	195B109    57	2779002032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.23198	-118.58872	01/25/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HALA KAUSAR MEAT MARKET. 1300 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53901	15041-20000-17647	4740 N ARCOLA AVE	91602	4	168B177   594	2420023001	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.15699	-118.35479	PV1 SFD. TOTAL SYSTEM SIZE 10.9KW DC/ 9.5KW AC USING MICROINVERTER SYSTEM WITH ENPHASE M250. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53902	15041-10000-08551	4931 N LANKERSHIM BLVD # C	91601	2	168B173    66	2353017001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.16057	-118.37233	new luminires and circuits in retail spaceplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53903	11041-20002-00529	2800 W RIVERSIDE DR	90039	4	151-5A207  93	5438025011	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	11/23/2011 12:00:00 AM	ADDRESS	34.10921	-118.26198	Plan check for revisions of an approved set of plans. Revision is the addition of an isolation transformer due to the use of transformerless inverters.  <<<<<<<<<Plan check for revision to approved plans. Revision to point of connection from supply side to load side and module type from 230W to 235W.  Derate main overcurrent protection from 400A to 200A.>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53904	14041-10000-27837	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.06307	-118.2	TI Plan check for Power and Energy, USC Imaging Center cyclotron.  New panels, transformer, and branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53905	18041-10000-25870	424 W PICO BLVD	90015	14	126A207   179	5134017004	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM			Reviewed by Supervisor	07/19/2018 12:00:00 AM	ADDRESS	34.03913	-118.26523	*****SEE APPLICATION COMMENTS**** PC FOR  TIME TENANT IN RETAIL 2 SPACE.  TOTAL AFFECTED AREA 1702 SQ.FT SCOPE INCLUDES NEW EQUIPMENT PANELS AND RECEPTACLES ( LIGHTS ARE EXISTING FROM CORE AND SHELL).  PERMIT PAID UNDER 18041-90000-17368THIS IS PLAN CHECK ONLY!	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53906	13041-10003-31899	16407 W HAMLIN ST	91406	6	180B137   507	2231003028	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.18854	-118.49054	(((3/25/2014- CHANGES MADE TO APPROVED SET OF PLANS. SPLIT INTO 2 STRINGS AND SUBPANEL FOR COMBINING THE STRINGS. NUMBER OF MODULES DID NOT CHANGE)))PV1.  Install 5.25 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverters: Enphase M215.  21 modules: Canadian Solar CS6P-250P	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53907	17041-10000-40566	6330 W SAN VICENTE BLVD # 250	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.06116	-118.36804	REPLACE LUMINAIRES AND LIGHTING CONTROLS IN OFFICE SPACEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53908	17041-20000-03616	15303 W VENTURA BLVD # 200&220	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	Plan check for Title 24 only. Project site is suites within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,668 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53909	12041-20001-31052	20815 W HORACE ST PV1	91311	12	207B109    39	2706008008	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.26734	-118.58694	((( ADDED ADDITIONAL 17 MODULES AND 1 COMBINER BOX )))INSTALL ROOF MOUNTED SOLAR, INTERCONNECT MAIN SERVICE PANEL.(5.39KW) Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53910	10041-20000-24601	4583 E HUNTINGTON DR SOUTH	90032	14	142-5A231  86	5213013025	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.08534	-118.18652	Replace Fire Alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53911	20041-10000-22764												Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53912	13041-10000-34613	4007 W PICO BLVD	90019	10	129B189   917	5081008015	C4-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.04763	-118.32313	NEW 800A, 120/240V, 3PH, 4WIRE, OVERHEAD SERVICE FOR 'PRINT LAND BUILDING' ; 1-STORY BUILDING. SCOPE OF WORK ALSO INCLUDES (6) NEW FEEDERS  .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53913	18041-20000-00864	21165 W ESCONDIDO ST	91364	3	165A107   417	2172026016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.14456	-118.59449	Note: $0.00 permit fee due to CA Senate Bill 1222pv1install roof mounted pv system sized 10.4kw interconnected with msp with two battery back up tesla power walls.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53914	17041-20000-13029	4123 N ST CLAIR AVE	91604	2	165B165  1154	2367013023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.14553	-118.39993	pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53915	16041-20000-31171	7779 W VERAGUA DR	90293	11	099B153    67	4114002014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	33.96481	-118.43382	PV1INSTALL ROOF MOUNTED PV SYSTEM (ACM) SIZED 10.5KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53916	15041-10000-36288	1212 S FLOWER ST 5TH FLR	90015	14	126A207    34	5138026030	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.04113	-118.26555	T-24, TI TO THE 5TH FLOOR OF AN (E) COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES  NEW LIGHITNG AND RECEPTACLES, CONNECTED LOAD IS LESS THAN 400AMPS. TOTAL SQ. FT. 11945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53917	19041-20000-32009	12680 N BRADLEY AVE UNIT # 6	91342	7	219B149    11	2506031038	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	07/13/2021 12:00:00 AM	ADDRESS	34.30069	-118.4534	POWER PLAN CHECK ONLY, FOR NEW 800 AMP 240/120 1 PHASE 3 WIRE SERVICE. SCOPE OF WORK INCLUDES 800A SERVICE AND A 800A PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53918	15041-10000-11730	10720 W ROCHESTER AVE	90024	5	132B153   539	4325013005	R1-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.05773	-118.43597	PV1.  Install 4.83 kW roof-mounted, utility-interactive PV system.  Ungrounded system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53919	14041-10000-17353	962 S BOYLE AVE	90023	14	124-5A221 339	5189001024	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Info Complete	12/08/2014 12:00:00 AM	ADDRESS	34.0339	-118.21929	PLANCHECK FOR POWER AND ENERGY. NEW 3 STORY WITH SUBTERRANIAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53920	15041-10000-11480	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	PIN	34.12750533	-118.21285206	T24 FOR RENOVATION OF RESTROOMS AT OCCIDENTAL COLLEGE BRAUN HALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53921	11041-20000-04136	7963 N VAN NUYS BLVD	91402	6	189B149   310	2210019004	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Finaled	02/08/2012 12:00:00 AM	ADDRESS	34.21603	-118.44897	INTERIOR NON-STRUCTURAL REMODEL ...COMBINING TWO RETAIL SPACES & CHANGING THE USE FROM RETAIL TO MEDICAL OFFICE. New 800A service, Panel boards & circuits. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53922	18041-10000-35946	11100 W SANTA MONICA BLVD 1100	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI IN AN EXISTING OFFICE SPACE IN PORTION OF SUITE #1100.T-24 ENERGY ONLY.  BLDG PERMIT: 18016-10000-28421	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53923	14041-20000-00547	14944 W CHATSWORTH ST	91345	7	207B149   421	2648004008	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.26432	-118.45785	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 5.18 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53924	13041-10000-17460	4550 W PICO BLVD SUITE D304	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	New tenant (Petsmart) in single story commercial building.  18,000 sq ft, retail and animal clinic.  Newly connected load over 400 A, 600 A rated panel.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53925	17041-10004-01942	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM			PC Info Complete	04/11/2019 12:00:00 AM	ADDRESS	34.18684	-118.3977	PC FOR CHANGES TO APPROVED SET FOR DELTA 11 CHANGES. SCOPE INCLUDES NEW PANEL AND TRANSFORMER WITH CIRUCUITS RELOCATION. REVISION TO SERIES COMBONATION TO REFLECT CORRECT INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53926	17041-20000-20357	7702 N BALBOA BLVD	91406	6	189B133   905	2205008029	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Issued	06/16/2017 12:00:00 AM	ADDRESS	34.21031	-118.50093	Plan check for power only. Replacing damaged 800A service panel and utility service due to LADWP transformer failure. Reconnecting existing unit panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53927	13041-10000-03033	1875 S CENTURY PARK EAST SUITE 1550	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM			PC Approved	02/06/2013 12:00:00 AM	ADDRESS	34.06115	-118.41457	T24 FOR EXISTING OFFICE SPACE. RELOCATION OF LIGHTING FIXTURES. TOTAL SQ FT 6132.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53928	17041-10001-37585	15050 W ALTATA DR	90272	11	123B129   573	4411024012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.03267	-118.52326	Plan check only, scope of work includes the revision of the single line diagram to match field conditions. and relocation of dryers and washers. Note changes under delta 1, clouded areas. ___________________________________PC for new house addition. Installing new 800A 120/240V service, new service equipment, four panels, circuits, lights, receptacles and equipment. Reconnecting existing panels to new service equipment. This is plan check only under combo permit 16014-30000-00663.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53929	13041-10001-22769	3000 W 6TH ST	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM			Verifications in Progress	11/05/2013 12:00:00 AM	PIN	34.06351748	-118.28745252	EXPEDITED PER APPLICANTS REQUESTPV2. ROOF MOUNTED PV INSTALLATION. SYSTEM SIZE: DC RATING 27.54 KW. AC RATING 23.4.  TRANSFORMER INVERTER- NEGATIVELEY GROUNDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53930	15041-10000-00464	707 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	33.78001	-118.24199	"Installation of new roof mounted solar PV array on existing locomotive repair facility.  20 strings with 14 modules per string connected to one 100 kWac ""Power Gate Plus"" inverter (480 Vac). ZERO FEES DUE TO 2012 SENATE BILL NO. 1222"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53931	19041-20000-50538	9237 N WAKEFIELD AVE #2	91402	6	198B149   423	2639008***	(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.23831	-118.44831	PV1.  Install 3.78 kW DC roof mounted PV system.  (12) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53932	15041-20000-23801	13425 S FIGUEROA ST	90248	15	078B201    80	6132004024	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM			Reviewed by Supervisor	08/25/2015 12:00:00 AM	PIN	33.90971921	-118.28334947	Plan check for power and Title-24 (energy).  Total area = 43,136 sq. ft.  Remodel of first and second floors of existing commercial low rise space.  Change from warehouse to office/storage space.  New 2,500 A service and distribution boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53933	19041-20000-50477	13263 N WHEELER AVE UNIT 13	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	10/16/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS (ENPHASE IQ7PLUS)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53934	19041-20000-11592	8335 N SHOUP AVE	91304	12	192B101   567	2004009008	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.22065	-118.61498	Plan check for a PV1 roof-mounted PV system. System size is 13.6 kWdc/11.4 kWac and consists of (1) inverter and (40) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53935	16041-10001-14225	6570 S WEST BLVD	90043	8	102B185    90	4006020022	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			01/13/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	33.97915	-118.33503	Zero dollar permit fee due per California Senate Bill 122201/13/2017 Changes to an approved set of plans (16041-20000-14225). Changes include replace optimizer from P320 to P700(P700 can connect to up to 2 module per optimizer) and replace modules from LG SOLAR 305N1C-B3 to LG SOLAR 320N1C-G4 and additional 2 modules added to system. System size: 120kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53936	18041-20001-35624	350 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A203 152	5111003039	[Q]M1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.01092	-118.27958	Revision to approved set of plans.  Change of feeder wiring details, equipment rating changes, and architectural layout and equipment location changes.  Approval for clouded revisions only.  (((ti to an existing commercial building (green house) with service upgrade 5000 amp.  adding new transformers, panels, circuits and backfeeding existing panels.  plan check for power and energy.serice to suppy the following address 4001 S. Broadway.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53937	19041-20000-47506	12800 W MILBANK ST	91604	2	168B161  1084	2362016033	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	34.15315	-118.41155	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM IS 5.12KWac. SCOPE OF WORK IS 14 AC MODULES, TWO SOLAR LOAD CENTERS, INTERCONNECTED TO AN EXSITING 200A SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53938	17041-20000-02928	23388 W MULHOLLAND DR	91364	3	168B093   135	2068001003	(T)RS-1XL, R3-1, RA-1, RA-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.1563	-118.63495	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR  NEW LANDSCAPE LIGHTING AND THEATRE LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53939	16041-10001-29411	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	"CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE REVISING FLOOR PLANS, REVISING SINGLE LINE DIAGRAM, ADDING HVAC EQUIPMENT, AND RELOCATING/ADDING LOADS ON PANEL SCHEDULES. ALSO REFEEDING DISTRIBUTION BOARD ""MS/CP"" TO A NEW UTILTY TRANSFORMER INSTEAD OF AN EXISTING  MEDIUM VOLTAGE SUBSTATION."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53940	19041-10000-52103	216 N LARCHMONT BLVD 216A	90004	4	138B189   584	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.07531	-118.32344	PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SPACE - TOTAL AFFECTED AREA = 1025 SF. SCOPE OF WORK INCLUDES INSTALLATION OF NEW PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53941	17041-20000-43348	18655 W ELKWOOD ST	91335	3	189B121   406	2103022001	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.21305	-118.54014	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53942	18041-10000-47329	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/02/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 670 FA DEVICES, AND 31 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53943	15041-20000-21211	5057 N ESCOBEDO DR	91364	3	171B105   982	2167017002	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Expired	07/31/2017 12:00:00 AM	ADDRESS	34.16236	-118.59209	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53944	14041-20000-02324	16201 W STAGG ST	91406	6	189B137    55	2205004047	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.21324	-118.48681	T24 FOR EXISTING RETAIL STORE. TOTAL CONNECTED LOAD DOES NOT EXCEED 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53945	18041-20000-34652	14013 W REMINGTON ST	91331	6	201B153   838	2644009005	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.24482	-118.43857	Plan check for PV roof mounted system, system size: 10.4kW AC with (2) 5.2 kW inverters and (30) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53946	19041-10000-16955	625 W COLLEGE ST	90012	1	135A215   133	5414003011	C2-2D-O	Central	Central City North	Historic Cultural North		2071.03	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.06526	-118.24063	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53947	18041-10000-14718	7313 N HESPERIA AVE	91335	3	186B125   840	2121001020	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.20342	-118.52636	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 7.59KW DC /7.04 KW ACSCOPE INCLUDES 22 AC MOUDULES WITH NEW PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53948	13041-10000-03348	654 N PALMERA AVE	90272	11	129B121   835	4414012009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	34.04684	-118.53803	PV1 for 2 story house. Total system size: 8.82 KW. 36 Modules used. [Invertor: Fronuis Model#: IG PLUS 10.0-1 @ 8.82KW] [Solar Module:Trina Solar Model#: TSM-245 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53949	17041-20002-09897	12601 W PIERCE ST Bldg 14	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	123-19-2018 Changes to an approved set of plan, Changes include addtion of sub-panel. All changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53950	17041-10000-13937	708 W 42ND ST	90037	9	114A201   165	5019016025	RD2-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	34.0069	-118.28619	PV INSTALLATION OF 3.2 KW DC/2.8 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOME. 10 AC MODULES. PLAN CHECK ONLY, PERMIT FEE IS UNDER 17041-90000-10118.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53951	15041-10002-10402	304 W ORD ST	90012	1	133-5A215 144	5408015003	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.06005	-118.23881	Changes to approved set per field installation. Change the light fixtures and qty. Changes under Delta-2. Permit under Master E#.<<ALTERATIONS TO AN EXISTING RESTAURANT SPACE. PC FOR TITLE 24 ONLY. SQ. FT. 930>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53952	13041-10000-15880	4545 N KATHERINE AVE	91423	4	168B153   684	2265017006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.15421	-118.44337	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SFD. SYSTEM SIZE IS 4.165 KW USING 24 MODULES AND A SINGLE INVERTER. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: POWER-ONE # AURORA PVI-5000-OUTD-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53953	15041-10000-06524	6320 N TOPANGA CANYON BLVD BLDG G	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.18578	-118.60536	NEW FIRE ALARM SYSTEM IN BUILDING G ON WESTFIELD PLAZA. 80 DEVICES AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53954	18041-10000-00535	728 E NOWITA PL	90291	11	108B145   841	4241020007	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			Reviewed by Supervisor	01/18/2018 12:00:00 AM	ADDRESS	33.99274	-118.4609	PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53955	18041-30000-36971	1900 S AVENUE OF THE STARS GROUND FLR	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.05979	-118.41671	PC FOR TITLE 24  ENERGY ONLY FOR T.I. WORK ON GROUND FLOOR RESTROOMS AND LOBBY IN HIGH RISE BUILDING.TOTAL AFFECTED AREA 891 SQ.FTSCOPE INCLUDES NEW LIGHT ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53956	13041-10000-27870	4335 S GLENCOE AVE	90292	11	105B153    56	4212004015	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	33.98632	-118.43959	Install a new fire alarm system - movie theater TI.  71 devices and 1 new FACP Silent Knight IFP-100ECS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53957	14041-20000-35114	6600 N TOPANGA CANYON BLVD #2106A	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. to a jewelry store on Level 2.  Install branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53958	19041-10000-45679	850 S LA BREA AVE	90036	4	132B181   468	5084003009	C2-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM			PC Info Complete	11/26/2019 12:00:00 AM	ADDRESS	34.0591	-118.345	PC FOR A NEW METHANE DETECTION SYSTEM (LEVEL 5), SCOPE OF WORK IS 16 DEVICES, ONE BATTERY BACKUP, AND A GAS DETECTION CONTROL PANEL AND A FIRE ALARM CONTROL PANEL. ((B#16010-10001-05471))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53959	11041-10000-13322	24101 W HATTERAS ST	91367	3	174B089   302	2046006010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.17354	-118.65123	NEW 8.6KW PV SYSTEM FOR A SINGLE FAMILY RESIDENCE.  OVER THE COUNTER PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53960	19041-20000-08138	1831 S MESA ST LOT 19	90731	15	012B201   794	7456029045		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	33.72725	-118.28612	PLAN CHECK FOR NEW SOLAR ROOFMOUNT PV SYSTEM 3.015KW DC/2.88KW AC, SCOPE OF WORK INCLUDES (9) SUNPOWER SPR-X21-335-BLK-D-ACPV PANELS WITH INTEGRATED MICROINVERTERS, ON A NEW SFD TOWNHOUSE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53961	18041-20000-31704	7843 N LANKERSHIM BLVD	91605	6	189B169   517	2310025***	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM			PC Info Complete	12/13/2018 12:00:00 AM	ADDRESS	34.21329	-118.38805	Plan check for fire alarm only. New fire alarm system for New 2-story commercial building.Note: below grade parking is shared between commercial building and existing 4-story apartment building. The 4-story apartment building is under application number 16041-20000-38463. permit fees paid under application number 18041-20000-30977this is plan check only.50 devices. existing FACP.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53962	11041-20000-07164	22440 W SHERMAN WAY	91307	3	183B101   100	2024016109	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			04/11/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.20079	-118.61614	ADDITION TO AN EXISTING FIRE ALARM SYSTEM.  48 NEW DEVICES NO NEW PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53963	16041-20000-08967	14143 W BURBANK BLVD	91401	4	174B153   773	2245027036	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Apartment			03/15/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.17232	-118.44138	New 10 unit 2-story apartment building over basement garage.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53964	10041-20000-07464	555 W 5TH ST 41st FL	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	05/20/2010 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check T-24 Energy for video conference lighting which are excluded if meets the requirments less than 2.5 watts per square foot of lighting in a videoconferencing studio provided the videoconferencing lighting is in addition to and separately switched from a general lighting system. On 41st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53965	14041-20000-01340	11119 N CABRIOLE AVE	91326	12	210B121   312	2717006004	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.27207	-118.54107	PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 7.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53966	18041-20001-44048	5158 N CALVIN AVE	91356	3	171B117   265	2163007023	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM			PC in Progress	11/25/2018 12:00:00 AM	ADDRESS	34.16547	-118.5551	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.6 kWdc/14.4 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (48) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53967	12041-10000-07169	2528 W OLYMPIC BLVD #110 & 111	90006	1	130-5A201 138	5076007036	C2-2	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	34.05226	-118.28483	NEW DENTAL OFFICE IN SUITE #'S 110 & 111. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53968	15041-20000-30941	920 W DOWNEY WAY 2nd Floor	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.02063	-118.28879	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the 2nd floor. Total lighting area = 2,520 sq. ft.Note: Building application filed under 15016-10000-04507	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53969	19041-20000-16808	8020 N CANBY AVE NO     4	91335	12	189B125   201	2102025***	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Apartment			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.21626	-118.53429	Plan check for PV roof mounted system, system size: 4.8kW DC, 5.0KW AC with 16 PV Modules and 1 inverter(5.0KW) Note to inspector: please verify AIC rating of 400A service equipment	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53970	15041-20000-07748	11846 N SHOSHONE AVE	91344	12	216B129   331	2601041057	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Closed	07/21/2015 12:00:00 AM	ADDRESS	34.28637	-118.51615	Plan check for PV1 roof mounted 14.5kW system with 58 enphase microinverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53971	17041-20001-43275	11633 W GORHAM AVE 1-10	90049	11	132B145   355	4401022028	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.05538	-118.46471	EXPEDITED PER APPLICANTS REQUEST. PV2. ROOMFOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53972	14041-10001-27226	8900 W DEVLIN PL	90069	4	144B169    70	5560036001	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.09456	-118.38498	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<INSTALL 12.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(48) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER(S): SOLAREDGE SE3800A-US-ZB-U & SE6000A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53973	19041-10000-33552	9026 N WOODLEY AVE	91343	12	195B141    69	2672001004	(Q)C2-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	09/13/2020 12:00:00 AM	ADDRESS	34.23441	-118.48487	Change to an approved set for Title 24 only in existing space Tenant Improvement. Total area: 4232 sq ft. change include changing fixtures type and replacing HVAC equipments.B#19016-20000-02499	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53974	11041-10000-12332	1139 S GLENDON AVE	90024	5	132B153   241	4363022010	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Public Safety Only			06/15/2011 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	ADDRESS	34.06007	-118.44389	Installation of a fire warning system with central station monitoring in an existing restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53975	12041-10000-21521	685 N SPRING ST	90012	1	133-5A215 166	5408014018	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Expired	04/04/2016 12:00:00 AM	PIN	34.05979754	-118.23833413	CHANGE OF USE OF RETAIL SPACE TO DINING AREA OF EXISTING RESTAURANT. EXISTING RESTAURANT OCCUPIES SPACE # H  AND THIS ADDITION OCUPPIES # E,F,AND G.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53976	18041-10000-02025	10036 N ILEX AVE	91331	7	204B161   708	2624001001	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Issued	01/18/2018 12:00:00 AM	ADDRESS	34.25266	-118.40943	PC for rooftop solar for 5kW ac system. Installing 24 modules (7.32kW DC) with optimizers and new central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53977	13041-10000-06131	17943 W CHATSWORTH ST	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.26501	-118.52499	New tenant (Pieology) in core and shell building of a single story building.  Install a new subpanel and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53978	14041-20000-01541	16417 W VENTURA BLVD	91436	5	168B137   347	2260009043	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.1575	-118.49052	pc for t24 energy only. all existing fixtures except work room. new lighitng. plan check for new lighitng in work room only. total area 100 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53979	19041-10000-37491	835 N FAIRFAX AVE	90046	5	141B177    69	5529021028	C2-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/24/2021 12:00:00 AM	ADDRESS	34.08649	-118.36166	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53980	17041-10000-12646	16914 W BLACKHAWK ST	91344	12	204B133   108	2684012034	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Issued	04/19/2017 12:00:00 AM	ADDRESS	34.2587	-118.50067	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 5,925 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53981	13041-10002-16250	1350 S RIDGELEY DR PV1	90019	10	129B177   775	5085033011	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	ADDRESS	34.04964	-118.35521	PV1. Original express permit for 13041-10000-16249 for a roof-mounted system with transformered inverter modified to transformerless inverter. Plan check only. (((INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE: 1.47KW   Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53982	17041-10000-12656	1166 S SOTO ST	90023	14	121-5A221  24	5170005026	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.02828	-118.2191	PC for energy only, outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 40,925 SQFT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53983	18041-20000-22020	6212 N YARMOUTH AVE	91316	5	177B129   162	2123030012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	07/14/2018 12:00:00 AM	ADDRESS	34.18274	-118.51942	Plan check for PV roof mounted system. System size: 5.76kW with 18 AC Modules .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53984	17041-20000-08158	2269 S GUTHRIE CIR	90034	5	126B165   477	4309017028	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.04224	-118.3932	pv1install roof mounted pv system sized 12.4kw (ACM) interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
53985	16041-10000-26794	189 S THE GROVE DR H-2	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR TENANT H2. SCOPE INCLUDES FOUR NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 2022 SQ. FT. b#16016-40000-17632	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53986	19041-20000-47593	3500 S CHESAPEAKE AVE	90016	10	120B181  1018	5046015032	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Closed	05/07/2021 12:00:00 AM	ADDRESS	34.02354	-118.34506	Fire alarm system for new construction.  (72) signaling line and notification devices with fire alarm control panel, cellular communicator, and graphic annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53987	17041-10000-17162	1415 W TORRANCE BLVD	90501	15	054B193   315	7351020019	M2-1VL, MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	33.84207	-118.30215	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 35,000 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53988	16041-10000-16918	3651 N MIMOSA DR	90065	1	154-5A217 252	5460004004	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.11615	-118.23065	PV1, rooftop solar installation 3.8 kW AC.    (16) TSM-250PA        (1) SE3800A-US    SEP300 is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53989	17041-20000-18653	13033 N GRADE AVE	91342	7	222B157   158	2512008029	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.30691	-118.42114	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53990	12041-10000-09905	300-302 S MARIPOSA AVE	90020	4	135B197   205	5502003009	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	12/20/2012 12:00:00 AM	ADDRESS	34.06885	-118.29903	PLAN CHECK POWER AND ENERGY FOR A CHANGE OF USE FROM DWELLING AND BANQUET HALL TO DENTAL OFFICE/OFFICE TENANT SPACES ON THE FIRST FLOOR AND OFFICE ON THE 2ND FLOOR.  NEW 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53991	14041-20001-21312	4101 N VANALDEN AVE	91356	3	162B117    33	2180008011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.14403	-118.55637	Expedite per customer request.(((19.8KW PV1 roof-mounted system including: (72) Solarworld Plus SW275 mono black, (2) Fronius IG Plus A 10.0 and 6.0 inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
53992	17041-10000-35325	20834 W SHERMAN WAY	91306	3	183B109    76	2137020041	C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.20086	-118.58738	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 15300 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53993	15041-10000-40143	801 S FIGUEROA ST Valet area	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.04789	-118.26153	TI for (E) valet area. Total area14,101sq.ft. PC for Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53994	19041-20000-51428	11540 W CLOVER AVE	90066	11	120B153   990	4250016014	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.02305	-118.43545	PV1.  Install 12.90 kW DC roof mounted PV system with 19.6 kWh energy storage system and 2 Energy Storage(9.8KWh).  Existing (43) modules with new 7.6KW and 3.8 KW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53995	18041-20000-36935	1823 S MESA ST LOT 17	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	33.72737	-118.28616	Plan check for PV roof mounted system, system size: 3.02KW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
53996	14041-10000-11911	7021 W HOLLYWOOD BLVD	90028	13	147B181   115	5548003020	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.1017	-118.34273	permit to be pulled at EPC counter only. Plan check for energy only. TI (E) RESTAURANT. SUBWAYS. 1 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53997	16041-10000-22610	7713 N GAZETTE AVE	91306	3	189B109  1069	2108032027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.21046	-118.58752	PV1 roof mounted solar system installtion to a single family home. Installing a central inverter rated at 6.0kw system and 20 solar modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
53998	12041-10000-07684	7116-7122 N LAUREL CANYON BLVD	91605	6	183B165    91	2321003037	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.19993	-118.39631	Plan check for replacing existing 800A service equipment with two 400A section to one 800 service equipment. Relocate existing branch circuits to new house panel and new panel. No new loads added. All existing panels shall be suitable for new fault current.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
53999	14041-10000-03087	1491 S OAKHURST DR	90035	5	129B169   275	4306005006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.05264	-118.39112	New 9.16kw DC PV system.  Rooftop mounted, sfr.   removed battery back up. 2-4-14	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54000	11041-20000-19198	1100 S GLENDON AVE 1080	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	T24 Energy/Emergency lighting for Tenant improvement to existing office #1080.  New ckts and working on existing work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54001	15041-20000-27046	4106 N VERDUGO ROAD	90065	14	157-5A217 251	5459026036	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.12528	-118.23158	Plan check for power and energy for fire damage inside electrical room. New 1600A service equipment and distribution equipment.Note: Each tenant shall pull permit for panel separately	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54002	16041-10000-42834	19840 W KINZIE ST	91311	12	201B113   410	2761019020	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.24822	-118.56594	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.2KWac.(35)MODULES-SUNPOWER SPR-X21-345-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54003	14041-20000-23941	12751 W MILLENNIUM B155	90094	11	102B161  1227	4211033053		West Los Angeles				2756.02	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	CHANGE OF USE, RETAIL TO RESTAURANTT.I FOR NEW RESTAURANT AND OUTDOOR DINIG AND PATIO AWNING (3000 SQFT)PLAN CHECK FOR POWER AND ENERGY. PLACE OF ASSEMBLYPLAN CHECK IN ACCORDANCE TO 2013 BUILDING EFFICIENCY STANDARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54004	16041-10000-30720	12121 W WILSHIRE BLVD SUITE 530	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.04386	-118.46816	TENANT IMPROVEMENT; NON LOAD BEARING INTERIOR PARTITIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54005	17041-10000-43757	11540 W SANTA MONICA BLVD	90025	11	126B149    98	4261012039	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Issued	12/06/2017 12:00:00 AM	ADDRESS	34.04508	-118.45259	REMOVE OUTDOOR METAL HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54006	13041-10000-13508	246 1/2 W 62ND ST	90003	9	105B201   890	6005021013	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Expired	07/13/2015 12:00:00 AM	PIN	33.98304763	-118.27763429	PV1.  Installation of roof-mounted 2.616 kW array to be interconnected into existing main service panel.  {8 modules: SunPower SPR-327NE-WHT-D} {Transformerless inverter: PowerOne PVI-3.0-OUTD-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54007	16041-20000-39553	20524 W LANTANA CT	91326	12	216B109   235	2701082049	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.2914	-118.58067	PV1.  Install 10.89 kW AC PV system, grid-tied.  (44) modules with Enphase M250 microinverters.$14.69 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54008	12041-10000-24586	207 S PATTON AVE	90732	15	018B193  1336	7452019031	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	33.74221	-118.30663	PV1 - PLAN CHECK 5.52KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING AURORA TRANSFORMERLESS INVERTER - 2 STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54009	12041-10001-06462	1657 S SHENANDOAH ST PV1	90035	5	129B169   966	4303009015	R2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2012 12:00:00 AM			Reviewed by Supervisor	05/31/2012 12:00:00 AM	ADDRESS	34.0485	-118.38255	PLAN CHECK FOR NEW ROOF MOUNTED  3.42KW PHOTOVOLTAIC SYSTEM. SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54010	10041-10000-24449	800 W 6TH ST 14th Floor	90017	9	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.05011	-118.2577	Ti in an existing office. EPC is for power and Energy.  The transformer impedance shall not be less than 4.5 percent.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54011	15041-20001-05819	7337 W PACIFIC VIEW DR	90068	4	156B177   611	2428016005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM			Reviewed by Supervisor	03/10/2015 12:00:00 AM	ADDRESS	34.12144	-118.35321	[[[[Expedite per applicant request]]]]]Plan check for PV1 roof mounted 9.8kW system using micro-interters with 46 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54012	16041-20001-12185	1854 N CANYON DR	90028	13	150A191   186	5586029005	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.10508	-118.31675	04/27/2016 Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (32) modules, and (1) combiner box. Standard plan is being used.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54013	12041-10002-08494	4157-4163 1/2 W BEVERLY BLVD	90004	13	138B197   270	5520025005	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.07642	-118.29977	SUPPL. PLAN CHECK AND PERMIT FOR A NEW 800 AMP SERVICE IN AN EXISTING COMMERCIAL BUILDING.  THE PANELS AND CIRCUITS WERE PERMITTED UNDER 12041-10000-08494.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54014	18041-20002-20448	4620 N TOBIAS AVE	91403	4	168A151   112	2265007008	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	34.15534	-118.45184	08-30-2018 Changes to permitted set of plans, Changes include relocate PV equipments from outside of the building to inside garage, All Changes has been clouded, Plan check only, Permit covered  under Master Application. Fees $0.00 due California Senate Bill 1222 ans Assembly Bill 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54015	13041-20000-27806	18907 W DEARBORN ST PV1	91324	12	198B121   623	2762025032	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Expired	11/09/2015 12:00:00 AM	ADDRESS	34.23745	-118.54522	((System is connected ahead of the main, Must be Approved by DWP)) PV1 TRANSFORMERLESS SYSTEM. 5.75 KW 23 MODULES AND 1 INVERTER. ZONING WAS COMPLETED ON ORIGINAL PLAN CHECK APPLICATION#: 13041-20000-21427	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54016	10041-10000-00753	1884 E 22ND ST	90058	14	117A215     6	5167006021	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	01/14/2010 12:00:00 AM		Permit Finaled	06/22/2010 12:00:00 AM	ADDRESS	34.0169	-118.23653	enclosing dock area and remode existing rest roomplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54017	18041-20000-31691	7729 W GRANITO DR	90046	4	150B177   569	5551007030	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM			Reviewed by Supervisor	09/27/2018 12:00:00 AM	ADDRESS	34.10362	-118.35985	Plan check for power only in Single Family Dwelling for 800A Service 2 story building. B#16010-30000-01754Plan check only, permit pulled under Building application 16010-30000-01754	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54018	14041-20000-27417	1985 E ZONAL AVE SUITE 605/-610	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.06159	-118.20463	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING. ADDING LIGHTING TO EXISTING POWER EQUIPMENT.  1560 SQFT. WORK TO BE PERFORMED ON THE THIRD FLOOR SUITE 304.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54019	12041-10000-17635	16255 W SAN FERNANDO MISSION BLVD	91344	12	210B137   298	2681011036	C2-1VL, P-1VL, QC2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			Reviewed by Supervisor	08/13/2012 12:00:00 AM	ADDRESS	34.27208	-118.48642	New Dollar Tree store.  Load is 505Amps per applicant.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54020	19041-10000-39725	581 N WILCOX AVE	90004	4	141B185   879	5523037034	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.08121	-118.33105	0$ fees per AB1414[EPLAN] PLAN CHECK FORCHANGES TO APPROVED SET - CHNAGES HAVE BEEN CLOUDED AND INCLUDE RELOCATION OF EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54021	18041-10000-01873	20955 W DE MINA ST	91364	3	171B109   418	2167016017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Issued	02/23/2018 12:00:00 AM	ADDRESS	34.16121	-118.59026	PC FOR INSTALLATION OF NEW ESS. SCOPE INCLUDES SONNEN ECO 10 (AC TYPE 7KW) WITH NEW SUBPANEL. RESIDENCE HAS EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54022	14041-10000-09898	13885 W POLK ST	91342	7	228B153   422	2503005026	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	08/02/2014 12:00:00 AM	ADDRESS	34.31999	-118.43604	PV1 ROOFMOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54023	16041-10000-34874	1411 W 190TH ST STE 675	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	33.85852	-118.30317	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE FOR SUITE 675. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2020 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54024	16041-20000-44107	12828 W RIVERSIDE DR	91607	4	168B161   460	2357033019	(T)(Q)RAS4-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.15745	-118.41266	Plancheck for power and energy. New four story hotel.  2000amp service Building permit: 16010-20000-05742	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54025	19041-10000-33007	2155 N MOUNT OLYMPUS DR	90046	4	151-5A175   9	5569026018	RE40-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.11151	-118.3688	$0 permit fee due to SB1222 and AB1414PV1, new rooftop mounted system, system size is roughy 70.83 KWdc/56.8KWac. Scope of work is 196 modules (Longi Green Energy LR6-72VH-340M) with micro inverters (Iq7Plus-72-2-us), leading to a PV subpanel (800A), terminanting in a exisitng 600A service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54026	15041-20000-43769	12101 W VAN NUYS BLVD 3	91342	7	216B165   292	2531001***	(T)(Q)RD6-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.28562	-118.39579	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54027	13041-10001-33053	13549 W RELIANCE ST	91331	6	192B157   122	2637009016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.22602	-118.42796	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54028	19041-20001-51033	4359 N CAMELLIA AVE	91604	2	165B169   415	2365018010	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	01/27/2021 12:00:00 AM	ADDRESS	34.14907	-118.38239	Expedited plan check fee.PV1.  Install 7.8 kW roof mounted PV system.  (104) roof shingle modules with 6 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54029	17041-10000-37385	6429 W SELMA AVE	90028	13	148-5A187 308	5546007018	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			Verifications in Progress	04/11/2018 12:00:00 AM	ADDRESS	34.09988	-118.33062	CONSTRUCTION OF TYPE 1A ONE STORY RETAIL OCCUPANCY BUILDING W/ 3 BELOW GRADE PARKING GARAGENOTE THAT ENERGY COMPLIANCE FORMS WERE NOT WITH THE SUBMITTED PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54030	13041-10000-09206	19270 W DEARBORN ST	91324	12	198B117   184	2762017037	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.23725	-118.55241	PV1 SINGLE FAMILY DWELLING 1 STORY HOUSE. 5.184 kW SOLAR INSTALLATION. ENPHASE MICROINVERTER M215. TOTAL MODULES 24: REC 250 PE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54031	07041-10003-24502	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Apartment			08/10/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.05562	-118.27458	Recalculate dwelling unit demand loads by optional method, 220.82.  Reduce various feeder overcurrent protective device ratings, and feeder AWG.  All residential feeders to be aluminum MC Cable as on previous approval.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54032	11041-20000-01508	5160 N VINELAND AVE #101A	91601	4	171B173  1378	2419001042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	08/02/2011 12:00:00 AM	ADDRESS	34.16418	-118.37009	T.I. for existing space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54033	12041-20002-30859	21728 W VENTURA BLVD	91364	3	171B105    41	2168024064	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.16814	-118.60169	Supplemental Plan Check for Emergency Lighting Only.     <<<Installing track lighting in an Existing Yoga Studio.  Not a first-time tenant and not a place of assembly per applicant.  Load is less than 400 amps.  >>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54034	11041-20000-22154	21650 W OXNARD ST s.100	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.17901	-118.60107	s.100 office t.i.Energy, emergencyFite Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54035	10041-10000-20750	2015 S SANTA FE AVE	90021	14	118-5A217  20	5167012036	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM			PC Approved	10/21/2010 12:00:00 AM	ADDRESS	34.02066	-118.2304	T-24 lighting plan check for remodeled space.  Existing permit number 10041-10000-15080.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54036	15041-20000-26207	7857 N SEPULVEDA BLVD	91406	6	189B145   472	2222002013	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	PIN	34.21366659	-118.46684864	PC FOR TITLE 24 ONLY. REMOVE AND REPLACE LIGHTS/ RECEPTACLES. TOTAL INDOOR AREA = 902 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54037	11041-20000-16710	1940 N BEL-AIR ROAD	90077	5	150A151   662	4370013023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2011 12:00:00 AM			PC Info Complete	08/02/2012 12:00:00 AM	ADDRESS	34.10426	-118.45104	New single family house with 800A service.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54038	13041-10000-22833	10585 W SANTA MONICA BLVD 3rd fl	90024	5	132B157  1074	4326033042	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	PIN	34.05439965	-118.42928472	F INTERIOR DEMOLITION AND TENANT IMPROVEMENT ON THE 3RD FLOOR.  NEW NON STRUCTURAL PARTITIONS, NEW CEILING AND NEW MILLWORK.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54039	19041-20000-23819	5550 N TOPANGA CANYON BLVD STE 150	91367	3	174B101   285	2146007119	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.17162	-118.60554	T24 PLAN CHECK FOR EXISTING COMMERCIAL BLDG STE 150. LIGHTS ONLY. TOTAL SQUARE FOOTAGE  = 4136 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54040	14041-10000-09260	5656 W MANCHESTER AVE	90045	11	096B169   549	4125018014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	33.95972	-118.38021	NEW TENANT IN AN EXISTING BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54041	12041-20000-15331	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.2215	-118.42999	Alteration to existing medical office building on basement, first, second, and third floors.  Remove the existing light fixutres and replace with new light fixtures.  All new light fixtures reconnect to existing branch circuits.  No new branch circuits, receptacles, and wiring are added or changed.  Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54042	12041-10000-19058	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	Change to lighting, receptacles, load for an existing restaurant.  Load is 132.7 Amps and Occupancy load is 56, per applicant.  PLAN CHECK ONLY for Energy,  with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54043	17041-10002-20044	10011 W CHEVIOT DR	90064	5	123B165   225	4316015006	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM			Corrections Issued	04/10/2018 12:00:00 AM	ADDRESS	34.03578	-118.40305	Supplemental plan check for relocation of loads and equipment. back-up batteries to be relocated to garage areaInstallation of new energy storage system.  New 200 amp load center and Tesla AC Powerwall 5.8 kVA 13 kWH battery.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54044	16041-20000-09794	13080 W DESMOND ST	91331	7	213B161   128	2524009013	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.28381	-118.41747	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54045	16041-20001-44967	3340 S MOTOR AVE	90034	5	120B161    80	4314023016	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.02863	-118.41004	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv array, roof-mounted on a commercial building.Interconnect with a 400A MSP. 20kW (10+10) ungrounded system. (72) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54046	19041-10000-49182	13704 W SATICOY ST	91402	6	186B157   139	2214023011	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Closed	10/05/2023 12:00:00 AM	ADDRESS	34.20934	-118.43163	FULL POWER & ENERGY PC FOR A NEW 800 AMP 208/Y120 3P 4W SERVICE. AFFECTED AREA 29900sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54047	14041-20000-01357	100 W WORLD WAY T1-Baggage	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	PIN	33.94684048	-118.40128468	New lighting, panels, and 15kva transformer in the baggage handling area of LAX Terminal 1.  FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54048	19041-10000-28640	1925 S CENTURY PARK EAST 8th Flr	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24, PC FOR ENERGY ONLY. T.I. FOR (E) OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPACLES. TOTAL AFFECTED AREA IS 1619 SQ. FT. B#19016-10000-22384	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54049	19041-20000-04788	5920 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Hermon		1837.02	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.10509	-118.18418	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a fire rebuild/tenant improvement. Total lighting area = 855 sq. ft.Note: Building application has been generated under 17016-20000-05871	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54050	16041-20000-29066	19850 W LINNET ST	91364	3	171B113    96	2164002013	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	PIN	34.1672967	-118.56561045	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system.Each module has a 300W power optimizer. (29) 285W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54051	19041-20000-17266	4675 N GALENDO ST	91364	3	166-5A105  98	2171024063	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.15144	-118.60088	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM FOR EXISTING SFD WITH EXISTING PV. SCOPE OF WORK INCLUDES NEW 200A LOAD CENTER, NEW 200A DISTRIBUTION PANEL, AND (2) 13.5 KWH TESLA POWERWALLS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54052	19041-20000-48950	19268 W NORTHFLEET WAY	91356	3	162B117   230	2177046009	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.13982	-118.55312	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 17.6 KW DC/15.2 KW AC. SCOPE OF WORK CONSISTS OF (55) PV MODULES WITH AND (2) 7.6 KW INVERTER$0 PERMIT FEE PER STATE SENATE BILL SB 1222 AND ASSEMBLY BILL AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54053	13041-10000-29740	19373 W VICTORY BLVD STORE 1656	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.1878	-118.5556	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW RETAIL SINGLE STORY 'ROSS' STORE. SCOPE OF WORK INCLUDES INTERIOR LIGHTING, ADDITION OF OFFICES, AND NEW EXTERIOR SIGNAGE. TOTAL AREA FOR LIGHTING = 31274 (INDOOR + OUTDOOR). EMERGENCY FIXTURES/EXIT SIGNS WILL BE ON UNIT EQUIPMENT. EXISTING 800A 277/480-Y-3PHASE, 4WIRE SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54054	10041-20000-13090	960 N LA BREA AVE	90038	4	144B181   634	5531015004	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM			Corrections Issued	08/03/2010 12:00:00 AM	ADDRESS	34.08868	-118.34386	ADDITIONAL BUILDING TO APPROVED PLANS (090412000013048)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54055	13041-20001-19173	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			Corrections Issued	09/16/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	((changes to approved set of plans. new fixtures. floor plan stays the same. ))existing mix use low rise. pc for t24 energy only for common areas. work done in leasing offices. total area 2104 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54056	11041-20000-27611	1513 S GRAND AVE 4th floor	90015	14	124-5A207 123	5134015027	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM			PC Approved	12/29/2011 12:00:00 AM	ADDRESS	34.03622	-118.26632	Existing Women's Clinic, on the fourth floor) that recently got their certificate for occupancy.  Client has decided to build out the conference room.  Work being done is in the conference room only!  Adding light fixtures to the space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54057	12041-10000-22157	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM	09/25/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check  for Fox Building 101 3rd floor office TI.PLAN CHK IS FOR TITLE 24 AND 1 EACH EMERGNCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54058	19041-20000-51850	2211 S UNION AVE	90007	1	124-5A201 181	5124001005	C2-1VL-O-HPOZ-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Apartment			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	06/03/2022 12:00:00 AM	ADDRESS	34.03545	-118.28328	Plan check for new fire alarm system, new fire alarm devices: 83 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54059	14041-20000-20436	7325 N GREENBUSH AVE	91605	2	186B157   520	2328026040	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			PC Info Complete	08/08/2014 12:00:00 AM	ADDRESS	34.20332	-118.42643	PC FOR POWER ONLY. NEW SERVICE EQUIPMENT DUE TO FIRE DAMAGE. CONSOLIDATION OF EXISTING 200A 1-PHASE AND A 400A 3-PHASE TO A SINGLE 800A 3-PHASE 4W DELTA. NO ADDITIONAL LOADS. RELOCATION OF LOADS TO NEW DISTRIBUTION EQUIPMENT. DUE TO 2013 BUILDING EFFICIENCY STANDARDS, NEW SERVICE EQUIPMENT REQUIRES LOADS TO BE IN AGGREGATE. PC FOR POWER AND POWER DISTRIBUTION PER 2013 BUILDING EFFICIENCY STANDARDS. EXISTING 480V SERVICE TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54060	19041-10000-36777	320 N LARCHMONT BLVD 3RD FLR	90004	4	138B189   329	5523021038	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.07681	-118.32346	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI IN AN EXISTING OFFICE SPACE. SCOPE OF WORK INCLUDES NEW LIGHTS, CONTROLS AND CIRCUITS. TOTAL AFFECTED AREA IS 4342 SQFT. B#: 19016-10000-24632	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54061	13041-20001-34357	4159 N STANSBURY AVE	91423	4	165B153   860	2266012017	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.14612	-118.44129	(((EXPEDITE FEES)))PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING 3 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54062	13041-10000-29594	1 WORLD WAY terminal 4-T30	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	33.94469	-118.39817	"TITLE,24 PART 6 LIGHTING TO INSTALL ILLUMINATED BLADE SIGN 1'8'W' X 4'10W FOR LAX TERMINAL 4, FOODCOURT. SIGN READS""UMAMI BURGER"" . total sign area = 8.33 sq ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54063	13041-20001-12937	1542 S 4TH AVE PV1	90019	10	126B189   202	5072027017	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.20	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.04414	-118.32108	((( PC ONLY FOR PERMIT ALREADY ISSUED. APPL # 13041-20000-12937. )))TRANSFORMERLESS INVERTER. MULTIFAMIY DWELLING. INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM AND MONITORING DEVICE. 3.924 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54064	10041-20000-04826	17424 W SHERMAN WAY	91406	12	183B129   173	2228020015	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM	03/17/2010 12:00:00 AM		Permit Finaled	06/10/2010 12:00:00 AM	ADDRESS	34.20088	-118.51285	Fire Alarm sytem for City School	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54065	17041-10000-33129	333 S SAN PEDRO ST	90013	14	129A213   301	5148005010	C2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.04644	-118.24303	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 6500 SQ.FT (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54066	16041-20000-44601	222 N MANHATTAN PL	90004	4	138B193   638	5517004014	R3-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	Apartment			12/20/2016 12:00:00 AM			PC Approved	12/20/2016 12:00:00 AM	ADDRESS	34.07541	-118.31012	2 STORY 8 UNIT APT WITH SUBTERRANEAN GARAGE.  PLAN CHECK FOR ENERGY IN COMMON AREAS.  BUILDING PERMIT FILED UNDER 16010-10000-01223	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54067	18041-20000-12015	6902 W LOS TILOS ROAD	90068	4	151-5A185  75	5549014025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM			PC in Progress	04/07/2018 12:00:00 AM	ADDRESS	34.11071	-118.33961	PC for power for new three story SFD with basement and attached garage. Installing 600A service, panels ,lights and receptacles. Permit fees paid under combo permit B# 15010-10000-03243.NEW 3-STORY OVER BASMENT ATTACHED 6-CAR GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54068	16041-20000-31931	14631 W MORRISON ST	91403	4	169-5A151  22	2263027006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.16043	-118.45203	Plan check for a PV1 roof-mounted PV system. System size is 7.3 kWac and consists of (29) micro-inverters, (29) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54069	14041-20000-27146	2306 S WESTWOOD BLVD	90064	5	126B157   613	4320002025	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.04228	-118.43015	ti to an existing one story commercial building.  Lighting to be added to existing power equipmment. plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54070	13041-10001-34712	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.04835	-118.25882	Revisions to permitted set of plansPLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. WORK ON FLOORS 3 - 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54071	14041-20000-11081	4834 N EXCELENTE DR	91364	3	168B101   477	2076008061	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.1572	-118.61688	Roof mounted PV system with microinverter, system size 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54072	11041-20000-27275	5326 N LEGHORN AVE	91401	5	171B161   196	2345016020	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	ADDRESS	34.16744	-118.4158	Install of photovoltaic system on the roof  of a single family dwelling single story, with enphase model m215 inverters.  A variance to use un approved equipment , M215 micro inverters, was submitted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54073	15041-10001-39194	3640 W WILSHIRE BLVD 1-209	90010	10	132B193    62	5093019018	(T)(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.06145	-118.30446	PC FOR REVISIONS TO APPROVED SET FOR FA IN A HIGH RISE BUILDING.CHANGES MARKED UNDER DELTA 3. SCOPE INCLUDES REMOVAL AND ADDITION OF DEVICES. REVISIONS TO VOLTAGE DROP AND BATTERY CALCULATIONS ON AFFECTED CIRCUITS.NUMBER OF AFFECTED DEVICES ABOUT 200  THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER MASTER. NEW FIRE WARNING SYSTEM FOR  7 STORIES 209 APT UNITS BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54074	13041-20000-22950	7969 N STANSBURY AVE	91402	6	189B153   471	2212024017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.21592	-118.44008	New 6.5kw rooftop PV system.  System is UNGROUNDED.  Plan check is only for PV, not for service upgrades or derating of main breaker.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54075	16041-10000-40958	1025 W ELYSIAN PARK DR	90026	1	141B213     3	5415005906	OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.08589	-118.24622	Replacing exiting fire alarm system; Scope include  one communication panel, (1) fire alarm panel and  (5) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54076	14041-10000-20844	651 N DIMMICK DR	90065	1	150A223   256	5466013012	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.10556	-118.21078	Installation of roof mounted solar PV system.  Total size = 4.6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54077	18041-10000-24449	4725 N RADFORD AVE 1-21	91607	2	168B169   645	2355014041	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.15663	-118.39239	FIRE ALARM TO A NEW 4 STORY CONDO BLDG. NEW FIRE ALARM PANEL AND 90 FIRE DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54078	19041-10000-47221	11120 W SHERMAN WAY	91352	2	183B173   117	2319002021	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM			Corrections Issued	12/20/2019 12:00:00 AM	ADDRESS	34.20103	-118.37291	NEW ROOF MOUNTED 204KW PV SYSTEM WITH 510 @ (400W) PV PANELS AND 255 OPTIMIZER AND TWO CENTERAL INVERTER RATED 99KW & 66KW ON A COMMERCIAL BULDING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54079	19041-10001-05103	1216 S BURNSIDE AVE	90019	10	129B181   180	5085015043	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.05276	-118.35301	PV1. New Solar system on existing residential roof-top. Total system size is 3.00KWdc / 2.673KWac. Note: Plan Check Only. Permit under original application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54080	18041-20002-16526	320 E 18TH ST	90015	14	123A209   211	5127022018	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.03073	-118.26056	05/22/2018 Changes to an approved set of plans. System size is now 33.3 kWac with (1) inverter and module count has increased to (112).*****Previous Work Description*****Express permit for a change of work description. Work description shall now read: PV2. Install roof mounted PV system sized 40 kWdc/30 kWac interconnected with MSP.Note: No fee. Department error. *****Previous Work Description*****PV2.  Install roof mounted PV system sized 10kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54081	15041-20000-20430	5404 N ENCINO AVE	91316	5	174B129  1016	2257010007	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2015 12:00:00 AM			Reviewed by Supervisor	07/08/2015 12:00:00 AM	ADDRESS	34.16922	-118.51405	Plan check for a PV1 roof-mounted PV system. System size is 6.3 kWac and consists of (25) modules, (25) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54082	14041-10000-17402	523 W 6TH ST Suite 1223	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Expired	08/04/2016 12:00:00 AM	PIN	34.04872199	-118.25441618	Title 24 plan check only.  Total area = 950 sq. ft.Installation of new lighting in existing commercial space.  No changes to power equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54083	18041-20000-07671	6261 W FOOTHILL BLVD	91042	7	198B205   168	2571006024	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.24164	-118.26777	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54084	15041-10000-04180	7000 W WORLD WAY WEST 24R-6L	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	PIN	33.93847109	-118.41935625	Replace airfield lighting (FAA) on runway.  Runway 24R-6L	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54085	14041-20000-23259	1225 S VERMONT AVE	90006	13	129B197   894	5078028006	C2-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			08/26/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.04827	-118.29188	PV2.  Install 14.84 kW utility-interactive PV system on apartment building rooftop.  3ph 120V/208Y transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54086	15041-10000-11360	411 E ROSE AVE	90291	11	111B141   409	4240007004	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM			Corrections Issued	04/16/2015 12:00:00 AM	ADDRESS	33.99785	-118.47476	PC FOR ENERGY. TI, CHANGE OF USE FROM MOTORCYCLE REPAIR TO RETAIL CAFE. TOTAL AREA 2309 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54087	12041-20000-19087	815 W COLORADO BLVD	90041	14	163-5A231 107	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	09/14/2012 12:00:00 AM	ADDRESS	34.14051	-118.18382	Plan check for energy and emergency lighting. 3rd Floor. 12044 sqft. Commercial low-rise building (72') per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54088	17041-20000-39319	1545 S FAIRFAX AVE	90019	10	129B173   994	5068021007	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			10/31/2017 12:00:00 AM	04/17/2018 12:00:00 AM		Issued	04/17/2018 12:00:00 AM	ADDRESS	34.04831	-118.36762	New 4-story 10-unit apartment building over one level subterranean garage.  600 A 120/240V 1ph-3w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54089	16041-10000-45095	515 S FLOWER ST STE 5000	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC FOR A TI ON THE 50TH FLR OF A COMMERCIAL HIGH RISE.SCOPE INCLUDES POWER AND ENERGY WITH NEW LIGHTING,  RECEPTACLES AND PANELS.TOTAL AFFECTED AREA OF 18592 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54090	18041-20001-45123	6727 N BUFFALO AVE	91401	2	180B157   158	2329001052	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.19284	-118.43027	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET CLOUDED CHANGES ONLY. REDUCTION IN SYSTEM SIZE TO 8.64 KW DC/7.705 KW AC CEC/ 7.68 KW AC. ALSO REMOVAL OF (7) PV PANELS AND THE PV METER. MAIN PANEL IS DOWNSIZED TO 200A. MINOR CHANGES TO FRONT PAGE, ROOF LAYOUT PAGES, SINGLE LINE, SIGNAGE PAGE, AND SERVICE LOAD CALC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54091	17041-20000-28602	11433 W ALBERS ST	91601	2	174B169  1079	2350007049	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			08/14/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.17056	-118.38016	Plan check for power and energy. (N) 59-unit, 4-story apartment building over 1-Level of subterranean garage. 1600A 120/208V 3ph 4w service. 26 typical units. T24 area: indoor-25,039sqft; outdoor-3,468sqft. Fire alarm variance on file.Building permit # 16010-20000-05094	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54092	17041-20000-08371	11755 W WILSHIRE BLVD ste 1250	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	PIN	34.04869377	-118.46238681	Plan check for energy only. TI to existing office suite 1250 on 12th floor of high rise office building. New lighting. 9,540sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54093	19041-10000-48986	111 E UNIVERSAL HOLLYWOOD DR 21st & 26t-h floor	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.13855	-118.36112	new lighting in the restroom/corridor on the 21st & 26 th floors of office buildingPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54094	17041-20000-31250	1707 N MANDEVILLE LANE	90049	11	135B137   507	4426017010	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.06404	-118.4925	Plan check for power only. (N) accessory living quarters for SFD. New 800A 120/240V 1ph 3w service.Reconnect existing SFD distribution to new service. this is plan check only.Permit fees covered under building combo permit 16010-30000-02321	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54095	19041-20001-29052	8378 N COZYCROFT AVE pv1	91306	3	192B109   516	2780024013	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.22227	-118.58201	Revision to approved set of plans.  Change of module type.  $0 plan check fee per State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54096	16041-10000-23088	220 S HOOVER ST	90004	13	136-5A201  49	5155007010	RD1.5-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Expired	08/07/2018 12:00:00 AM	ADDRESS	34.06993	-118.28419	PV 7.8 kw dc rooftop solar array on a triplex unit. with 2 meters and one address.   (30) SW 260   (1) FRONIUS 7.6 PRIMO	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54097	14041-10000-21992	9857 N CEDROS AVE	91402	6	201B149   215	2650019005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.2497	-118.45125	PV1 6.375KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(25)modules: {KYOCERA KD255GX-LFB3}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54098	13041-20001-21766	15206 W PARTHENIA ST	91343	6	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.2281	-118.46381	((CHANGES MADE TO APPROVED SET OF PLANS. SCOPE OF WORK ONLY COVERS OCCUPANCY SENSORS, ALL LUMINAIRES ARE EXISTING.))Plan check for energy only. No exam rooms in scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54099	14041-20000-16204	22300 W MULHOLLAND DR	91364	3	165B101   186	2173001015	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.14916	-118.61059	Plan check for energy only. Remodel of ground floor of single-story library. New lighting, incl. emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54100	14041-20000-18646	12051 W BURBANK BLVD	91607	2	174B165   720	2340028035	C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM			PC Info Complete	07/10/2014 12:00:00 AM	ADDRESS	34.17231	-118.39576	PLAN CHECK FOR ENERGY ONLY.  TI TO AN EXISTING SCHOOL ONE FLOOR.  NEW LIGHTING WITH EXISITNG CIRCUITS NO NEW LOADS.  1673 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54101	15041-20000-05476	225 S LINCOLN BLVD	90291	11	111B145   529	4240019061	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM			PC Approved	06/23/2015 12:00:00 AM	ADDRESS	34.00183	-118.46926	Plan check for Title 24 only. Project site is existing commercial space (Whole Foods). Total lighting area = 2,594 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54102	16041-20001-39253	1315 E OPP ST	90744	15	033B213   613	7425033022	[Q]R2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	33.78382	-118.24702	plan check for lost set of plans. this is plan check only.pv1install roof mounted pv system sized 2.6kw interconnected with msp.  standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54103	16041-20000-09307	637 N GULF AVE	90744	15	030B205   758	7416017013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	33.77757	-118.27285	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54104	19041-10000-25023	1390 E 7TH ST	90021	14	124-5A215   2	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	08/07/2020 12:00:00 AM		Issued	08/07/2020 12:00:00 AM	ADDRESS	34.03498	-118.23893	PLAN CHECK FOR POWER ONLY. NEW CONNECTION FROM AN EXISTING MEDIUM VOLTAGE DISTRIBUTION BOARD. NEW 4.8KV / 480 V TRANSFORMER AND TEMPORARY INSTALLATION OF A 1000A DISTRIBUTION BOARD FOR CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54105	16041-20000-13984	9814 N PENFIELD AVE	91311	12	201B113   381	2761015012	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.24844	-118.56945	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. PV addition system size is 6 kWac and consists of (2) inverter, (30) modules, and (1) load center. Total system size is 9 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54106	14041-20001-12086	19200 W LASSEN ST	91324	12	201B121   161	2762003026	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.24973	-118.55147	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 11.73kW(2) SolarEdge #SE5000A-US-ZB-U transformerless inverters(46) Trina Solar #TSM-255PA05.18 pv modules(46) power optimizers (1) Load center 125Amp]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54107	14041-10000-00608	1458 S SAN PEDRO ST #L-23	90021	14	123A209   397	5132027***	M2-2D	Central		Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with fluorescent fixtures in 735 sq. ft. retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54108	19041-20000-40374	18444 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54109	19041-20000-06850	14006 W RIVERSIDE DR SPACE 23	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	100A 480Y/277V service to tenant improvement.  Plan check provided per applicant request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54110	17041-20000-18100	3671 N SUNSWEPT DR	91604	2	162B165   878	2376011008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.13845	-118.40509	Plan check for solar pv system, roof-mounted on SFD.20kW ungrounded system. (77) 340W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54111	16041-10000-15134	11011 N CORBIN AVE	91311	12	210B117    97	2708009015	(T)(Q)RA-1-H, (T)(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Issued	09/14/2016 12:00:00 AM	ADDRESS	34.26836	-118.56416	PC FOR ENERGY ONLY. OUTDOOR LIGHTING FOR HARDSCAPE - PRIVATE TRACT DEVELOPEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54112	14041-10000-29745	12626 W ADDISON ST	91607	2	171B161  1087	2357025057	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.16113	-118.40808	This is a roof top 8.38 kw solar one story.  32 modules and one inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54113	13041-10000-28001	1420 S FIGUEROA ST	90015	14	126A205   166	5134009019	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			10/08/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.03815	-118.26937	NEW FIRE ALARM SYSTEM.  6 LEVELS WITH ROOF, 2 UNDERGROUND PARKING LEVELS. 2 PANELS. 484 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54114	19041-10000-14855	13100 W SATICOY ST	91605	2	186B161   426	2303023031	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Issued	04/23/2019 12:00:00 AM	ADDRESS	34.20722	-118.41821	Remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54115	16041-10001-09714	450 S WESTERN AVE # 213	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM			PC Approved	04/25/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	PC only for Power system: first time tenant (per field inspection). Permit and T-24 approval under master: 16041-10000-09714<<T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM EXISTING RETAIL TO BANK. SCOPE INCLUDES NEW LIGHTS AND THREE NEW PANELS. TOTAL AFFECTED AREA IS 1005 SQ. FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54116	18041-20000-47046	19225 W SUPERIOR ST	91324	12	201B117   376	2762005011	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Issued	12/11/2018 12:00:00 AM	ADDRESS	34.24674	-118.55263	PV1.  Install 12.54 kW DC roof mounted grid tied PV system.  (38) modules with 9 kW and 3 kW string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54117	19041-20000-15151	12746 W JEFFERSON BLVD SUITE 2200	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	33.97756	-118.41709	Remodel/addition of (E) restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54118	10041-10000-19020	12920 W RUNWAY ROAD	90094	11	102B157   315	4211021030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	06/20/2011 12:00:00 AM	ADDRESS	33.97447	-118.42112	New fire alarm system for 3 story residential building. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54119	19041-10000-26309	20900 W SESNON BLVD	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	01/05/2024 12:00:00 AM		Issued	01/05/2024 12:00:00 AM	ADDRESS	34.29609	-118.58894	Energy plan check for a private Street Lighting for Tract Homes. Scope includes new lighting and equipment with a total lighting  area of 109,120 Sqr Ft.  Building Permit: 18030-10000-06031	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54120	16041-20002-02542	21155 W CALIFA ST	91367	3	177B105   104	2149002026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.17716	-118.59277	REPLANCHECK DUE TO LOST PLANS, PLANCHECK ONLY. Plan check for Title 24 only T.I. existing building. Total area: 14,556 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54121	13041-20000-11045	1305 S ABBOT KINNEY BLVD	90291	11	108B145  1166	4239027002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	33.99127	-118.46797	NEW RESTAURANT. NEW 800A RATED EQUIPMENT. PC FOR POWER AND ENERGY. ORIGINAL PLAN CHECK EXPIRED, APPLICATION IS FOR RE-SUBMITTAL AND CHEANGES TO PREVIUOS PLANS. THIS APPLICATION IS NEW SUBMITTAL.((((LOCATION IS IN METHANE ZONE, UNDERGROUND WORK INVOVLED. PC FOR METHANE MITIGATION, ADDITIONAL PC HOURS ADDED)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54122	12041-20000-22468	20740 W MARILLA ST	91311	12	201B109   177	2748004045	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Closed	03/02/2015 12:00:00 AM	ADDRESS	34.24795	-118.5856	Relocate machinery, additional lights (with emergency lighting)  & AC in an existing industrial building.  Not in a classified/hazardous location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54123	19041-20000-29985	4909-4909 1/2 S CENTRAL AVE	90011	9	111A209   152	5108018003	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2292.00	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	33.9989	-118.25665	Remodel of (E) retail spaces.  Plan check for energy.  Permit for lighting circuits only - subpanels and other circuits under separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54124	15041-10000-18589	614 E TERMINAL WAY Primary-Mar Bldg	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	33.74201	-118.26431	New fire warning system for Primary Marine Building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54125	18041-10003-06012	4141 W SANTA MONICA BLVD Basement-Parking	90029	13	145-5A201 428	5429001048	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.09161	-118.28307	change to an approved set. change includes adding 3 exit signs and removing one onlyoriginal scope:Replacing existing Lights in the Basement / Parking area with new LED lights. T-24 Energy Only.Affected Area: 11,825 SFTBuilding Permit:17016-10000-17688	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54126	10041-10000-25739	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.04842	-118.33486	New electrical for Lowe's.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54127	15041-20000-11286	8640 W 3RD ST #101	90048	5	138B169   564	4334011021	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.07338	-118.38114	Plan check for T24 only for pharmacy area. Total area: 606 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54128	16041-10000-23010	1488 W 45TH ST	90062	8	111B193   327	5016009005	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Expired	08/16/2018 12:00:00 AM	ADDRESS	34.00269	-118.3031	PV1, INSTALL NEW 5.83 KW DC ROOF-MOUNTED FOR A ONE UNIT OF A 3-UNIT BUILDING.(22) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54129	10041-10000-13977	11307 W MISSISSIPPI AVE	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	09/27/2010 12:00:00 AM	ADDRESS	34.03947	-118.44296	TI IN AN EXISTING RETAIL STORE. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54130	16041-10000-04424	22458 W VENTURA BLVD	91364	3	171B101   218	2040034010	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			02/08/2016 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.16795	-118.61638	T-24, NEW OUTDOOR LIGHTING TO AN (E) RESTAURANT. TOTAL SQ.FT. 1500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54131	13041-10000-03649	100 N LA CIENEGA BLVD 231	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.07466	-118.37629	TI OF EXISTING RETAIL SPACE FOR USE AS RETAIL SPACE. TOTAL SQ FT. 3037. PC FOR T24 ONLY, ENERGY COMPLIANCE. THIS IS A PLAN CHECK ONLY APPLICATION. PERMIT HAS BEEN PULLED UNDER APPLICATION NUMBER 13041-10000-09549.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54132	14041-10000-21047	4346 N EMPRESS AVE	91436	5	165B133   154	2291001007	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.15036	-118.50378	PV1, INSTALL 13.5 KW DC ROOF-MOUNTED SOAR ARRAY INTERCONNECT WITH MAIN SERVICE PANEL.No fees due to Senate 1222. Mehdi(54) MODULES: KYOCERA KD250GX-LFB3(2)INVETERS: SOLAREDGE  SE5000A-US-ZB-U & SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54133	12041-20000-15439	6801 W HOLLYWOOD BLVD SPACE B2-# 243	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Approved	07/12/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	T-24 lighting plan check for new retail store Space B2 # 243.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54134	18041-20000-24593	24016 W BESSEMER ST	91367	3	177B089   449	2045006017	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.18124	-118.65025	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54135	16041-20000-20114	13674 W JUDD ST	91331	7	207B157   688	2619027015	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.26366	-118.43065	PV1. ROOFMOUNTED SOLAR SYSTEM/ SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54136	16041-10000-21833	5134 E DARTMOUTH AVE	90032	14	138A235   114	5216020014	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.07329	-118.17471	NEW PV1 SYSTEM 5 KW AC ROOF MOUNTED. INCLUDES (17)MODULES (KYOCERA KU2656ZPA)   AND 5KW INVERTER(ABB PVI-5000-OUTD-US-Z-A).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54137	14041-10000-13053	9649 W LAWLEN WAY	90210	5	144B161   412	4355019043	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Expired	08/01/2016 12:00:00 AM	ADDRESS	34.09484	-118.41636	"PV1 22.715KWdc. 208V. microinverter. NONstd. ???story. Roofmount. [(77) inverters: {MICROINVERTER: ENPHASE ENERGY M250-60-2LL-S22]}]. [(77)modules: {LG295N1-C-A3}]     'Expedited plan check per applicant request' Plan checker to verify system size."" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54138	18041-20001-43433	12400 N MCLENNAN AVE	91344	12	219B133   546	2609026045	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.29504	-118.50083	Expedited plan check fee. PV1.  Install 11.4 kW roof mounted grid tied PV system.  (34) modules with 11.4 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54139	16041-10000-03730	5401 N SHIRLEY AVE	91356	3	174B117   649	2164017008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.16903	-118.55798	PV1 roof mounted system to a single family home. Microinverter total rating system: 11kw. (44) modules. (100) A Load center with a monitoring system.Note: Low permit fees and $0 fee due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54140	16041-10000-02085	17532 W SUPERIOR ST	91325	12	201B129   281	2755009020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Closed	05/20/2016 12:00:00 AM	ADDRESS	34.2466	-118.51692	PV1, Install 12.19 KW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (2) INVERTER:  ABB PVI-4.2 & 6000-OUTD-S-US-Z-A.  (46) Modules: KYOCERA  KU2656ZPA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54141	19041-20000-46728	3253 N LONGRIDGE TER	91423	4	159B161   368	2385011013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.12931	-118.41831	Plan check for PV roof mounted system, PV system size: 11.45KW AC, 12.96KW DC with 36 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54142	18041-20000-37308	20703 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.29305	-118.58483	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54143	14041-10000-32784	865 S FIGUEROA ST	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.04653	-118.26275	Energy plan check for an office T.I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54144	18041-10000-22428	1030 N SWARTHMORE AVE 4-104B	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first time tenant. Total lighting area = 513 sq. ft.Note: Building application has been generated under 18016-10000-12045	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54145	14041-20001-16506	5938 N JUMILLA AVE	91367	3	177B117   711	2153020028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	07/22/2014 12:00:00 AM	ADDRESS	34.17859	-118.56375	EXPEDITE FEES))PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 7.6 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. CONNECT TO 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54146	14041-20000-17620	4227 N LANKERSHIM BLVD	91602	2	165B177   886	2423026001	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Corrections Issued	08/07/2014 12:00:00 AM	ADDRESS	34.14659	-118.36379	TI to (E) AIDS Healthcare Foundation medical lab & retail sales.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54147	10041-10000-15485	8101 W MANCHESTER AVE	90293	11	096B153   675	4115013031	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	12/20/2010 12:00:00 AM	ADDRESS	33.95889	-118.43778	TI IN AN EXISTING RETAIL STORE. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54148	13041-10001-33007	19041 W CELTIC ST	91326	12	210B121   615	2718011001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Verifications in Progress	03/14/2014 12:00:00 AM	ADDRESS	34.2693	-118.54777	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 9.25KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(37) TRINA SOLAR # TSM-250(37) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A(1) SOLAREDGE # SE5000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54149	18041-10000-21800	1901 1/2 S BUNDY DR	90025	11	123B149   379	4259019014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.03435	-118.45789	INSTALLING A NEW FIRE ALARM PANEL WITH NEW AND EXISTING DEVICES IN A PARKING STRUCTURE. TOTAL OF (30) NEW DEVICES AND (1) FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54150	18041-20000-03530	5359 W ADAMS BLVD	90016	10	123B177   926	5043002002	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.03265	-118.35992	Plan check for power and energy. Project site is a tenant space in an existing commercial building. Project scope is a first-time tenant/tenant improvement. Total lighting area = 3,168 sq. ft.Note: Building application has been generated under 17016-30000-38624	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54151	14041-10000-07345	13200 S ESTRELLA AVE #A	90248	15	081B201   340	6132003033	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	33.91286	-118.28606	TI. NEW LIGHTING FOR A STORAGE.. EPC IS FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54152	13041-10000-32027	8425 N WEBB AVE	91352	6	192B165   338	2633007005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.22357	-118.39509	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING WITH (E) 200A MAIN. SYSTEM SIZE IS 5 kW DC WITH (20) MODULES RENESOLA JC250M-24/BB IN 1 STRING, AND (1) SOLAR EDGE INVERTER SB5000A-US WITH OPTIMIZERS OP250-LV ON NON-STANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54153	15041-10001-40493	8000 W SUNSET BLVD C-110	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.09783	-118.36466	"6/8/16: Supplemental PC and Permit per field installation: additional two ""5.1-20kW"" circuits and adjusted load calc.; Revised wattage of F1 fixture.  Changes moted under Delta-1<<Change of use from retail to medical office. TI to existing commercial building. Plan check for power and energy. Total sqft. 1,397.Note: Building application has been created under 15016-20000-20920>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54154	13041-20000-33562	24642 W STONEGATE DR	91304	12	186B089    55	2017029009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.20975	-118.6573	New 11.25 kw rooftop PV modules for an existing sfr. ***LOW PERMIT FEES DUE TO 2012 SENATE BILL***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54155	10041-20002-16539	225 S 26TH ST #25	90049	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			10/01/2010 12:00:00 AM			PC Info Complete	10/01/2010 12:00:00 AM	PIN	34.04786183	-118.49061927	Plan check for T-24 energy (general/emergency) lighting for restaurant/market TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54156	18041-10000-05349	5700 N RUDNICK AVE	91367	3	174B101   158	2146010015	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.17388	-118.61212	REPLACE OUTDOOR AND INDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54157	13041-10001-29531	7607 N RUDNICK AVE	91304	3	186B101   141	2012020082	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.2086	-118.6123	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54158	18041-20000-23675	226 N LAKE ST	90026	13	136-5A205 169	5157020023	R4-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			06/25/2018 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.06878	-118.2701	New apartment building with 1200A 208Y/120V 3ph-4w service.  Building permit filed 17010-20000-05064	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54159	16041-10000-38683	1700 E CESAR E CHAVEZ AVE L100	90033	14	130-5A221 257	5174008024	C2-1-RIO-CUGU, [Q]R5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.05093	-118.21753	Power plan check for an existing dialysis medical center (OSHPD-3); total 3 circuits is added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54160	17041-20000-30269	21730 W DEVONSHIRE ST	91311	12	204B105   294	2747015007	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.25707	-118.60282	Plan check for solar pv system, roof-mounted on commercial building.10kW ungrounded system. (34) 380W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54161	14041-10002-00419	6544 W HOLLYWOOD BLVD	90028	13	148-5A187 185	5547015018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM			PC Approved	02/27/2014 12:00:00 AM	ADDRESS	34.10142	-118.33267	Changes to design spec to match installed design per inspector request.  (((T24 PART 6 ENERGY FOR (E) RETAIL 2 BUILDING STORY. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 7825 SQ FT. ALL WORK WILL BE INTERIOR.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54162	18041-20000-46238	8310 N PONCE AVE	91304	12	192B097   416	2004001030	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.21997	-118.62123	PV1.  Install roof-mounted PV system. System size is 10.8 kWdc / 9.75 kW CEC-AC and consists of (2) inverters, (36) modules, (2) load centers, (1) transformer, and (1) back-up battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54163	12041-10002-24962	4560 N COMBER AVE PV1	91316	5	165B129    63	2290018003	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.15238	-118.51607	PVI:  PV ssytem for a single family residence.  This project has already been permitted under 12041-10000-24962.  This is a plan check only application.  Installing 41 modules, 1 inverter 3.1-5 KW and one inverter 5.1 -10 KW.  <<<<<ROOF MOUNTED SOLAR, (41) MODULES. 10KW Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54164	15041-10000-34252	2500 S SIGNAL ST BERTH 59	90731	15	018B201   298	7440026903		Harbor	PORT OF LOS ANGELES			2961.00	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM			PC Info Complete	01/25/2017 12:00:00 AM	ADDRESS	33.72053	-118.27222	AT BERTH 59, INSTALLATION OF SERVICE EQUIPMENT TO SUPPLY FUTURE STATE CERTIFIED MODULAR BUILDINGS AND A WAREHOUSE AT THE BERTH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54165	18041-10000-11519	20721 W MARILLA ST	91311	12	201B109   154	2748004040	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.24819	-118.58497	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54166	17041-10000-08657	17299 W PACIFIC COAST HWY	90272	11	126B117   665	4415019008	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.03877	-118.55471	PC for energy only, outdoor. Replacing HID fixtures with new LED ones. Area: 15,330.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54167	15041-10002-01075			11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	PIN	33.97828408	-118.41198037	((((5/10/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO ENERGY CALCULATIONS, OCCUPANCY SENSORS AND LIGHTING SWITCHES.  THE CHANGES APPLY TO ALL THE FOLLOWING APPLICATION NUMBERS AS NOTED BELOW.Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps. Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54168	19041-20000-03820	14920 W JADESTONE DR	91403	4	162B149   576	2278011009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	34.1369	-118.45874	Plan check for PV system and battery back up system, PV system size: 9.765KW with 31 PV Modules. Battery back up system size: 27KWh with 2 Tesla Powerwall 2.0.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54169	19041-10001-49767	3262 S BUTLER AVE	90066	11	117B157    30	4250020011	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			PC Approved	12/16/2019 12:00:00 AM	ADDRESS	34.02066	-118.43058	Expedite per applicant request. NEW ROOF MOUNTED PV SYSTEM WITH 128 PV TILES (TESLA SRV 3) AND 2 CENTRAL INVERTERS( DELTA SOLIVIA 5.2 & DELTA SOLIVIA 3.8  )  ON A SINGLE FAMILY HOME. SYSTEM SIZE IS 7.48 KWdc AND 9 KWac WITH 3 ENERGY STORAGE SYSTEMS (TESLA POWERWALL)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54170	12041-10000-08101	3534 N DIXIE CANYON PL	91423	5	159B157   108	2386031003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	04/12/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	ADDRESS	34.13473	-118.42316	New 3.01kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54171	19041-10000-15816	11100 W SANTA MONICA BLVD 3RD FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	Energy plan check for INTERIOR REMODEL OF CORRIDOR, LOBBY, AND RESTROOMS ON THE 3RD  FLOOR OF HIGH RISE OFFICE BUILDING. Scope includes new lighting and equipment with a total area of 789-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54172	18041-20000-31208	1032 W 18TH ST	90015	1	126A203   211	5135026012	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.03916	-118.28001	Plan check for a fire alarm system for a commercial building. Fire alarm consists of (1) FACP and (49) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54173	14041-20000-04953	16000 W VENTURA BLVD	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.15584	-118.48164	T.I. to existing high rise building 9th floor, suite #900.  Install/relocate lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54174	18041-10000-34080	14455 W ROSCOE BLVD	91402	6	192B149   361	2638022044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.22172	-118.44839	PLAN CHECK FOR TITLE 24 ONLY FOR - CHANGE OF USE FROM RETAIL AND DANCE STUDIO TO OFFICE WITH WORK INCLUDING: REMOVAL OF NON-BEARING DEMISING WALL AND PARTION WALLS, AND MILLWORK - TOTAL AFFECTED AREA = 2003 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54175	18041-10000-45079	11954 W WASHINGTON PL	90066	11	111B157   367	4233016017	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.00202	-118.42492	T-24 PLAN CHECK ONLY TO A TI OF AN OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUITS. TOTAL SQ. FT. 2808	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54176	15041-10000-36839	11721 W RUNNYMEDE ST	91605	2	186B169   538	2317010020	C2-1VL, R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Public Safety Only			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.20585	-118.38836	FIRE WARNING SYSTEM FOR 4-STORIES APT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54177	19041-20000-51955	11435 N SKYLAND ROAD	91040	7	213B189    39	2551004006	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.27732	-118.31558	Plan check for PV roof mounted system, PV system size: 14.1KW DC 12.44KW AC CEC with 47 PV Modules and 47 Enphase, 2 sub-panels connected to existing 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54178	18041-10000-34195	10703 W VANOWEN ST	91605	2	183B177    62	2466017023	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Issued	09/07/2018 12:00:00 AM	ADDRESS	34.19414	-118.36449	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54179	17041-20000-35936	281 S FIGUEROA ST ste 200	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.0554	-118.25452	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.  2nd floor suite 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54180	15041-10000-15628	3829 S BROADWAY	90037	9	117A203   251	5122038024	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.01336	-118.27776	TI TO AN EXISITNG SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 4091.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54181	14041-20002-12029	12642 W SANDHILL LANE Unit #2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM			PC Approved	10/24/2014 12:00:00 AM	ADDRESS	33.97765	-118.41437	REVISIONS TO AN APPROVED SET OF PLANS.  REMOVAL OF SMS MONITORING SYSTEM.Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 2 of 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54182	14041-10000-32078	17900 W CHATSWORTH ST	91344	12	207B129   441	2731008022	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			11/18/2014 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.26468	-118.52395	Renovations to an (E) bank.  Electronic banking equipment kiosks and (2) new private offices.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54183	19041-20000-51074	12143 W VIA SANTA BARBARA	91342	7	228B165    83	2581006***	(Q)RD6-1-K	North Valley		Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	34.31938	-118.39802	PV1.  Install 4.16 kW roof mounted PV system.  (13) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54184	13041-10000-12998	380 WORLD WAY Space T26	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED FIRST TIME  TENANT IMPROVEMENT N SPACE T26  (TBIT ).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54185	15041-10000-22371	7120 N BELLAIRE AVE	91605	2	183B161   155	2324021012	[Q]RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.19983	-118.40929	Plan check for power and energy. Project site is a new 4-story, 29-unit apartment building. Building is 3-story residential above 1-story street level parking garage. Service size is 1,200 Amps.Note: Building plan check under application number 15010-10000-01619	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54186	16041-20000-07813	19050 W OLYMPIA ST	91326	12	207B121   436	2728012017	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.2641	-118.54823	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (29) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54187	16041-20000-27263	8430 N COLBATH AVE	91402	6	192B153   377	2638036012	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.22433	-118.43742	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.15 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54188	16041-10005-39304	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.01173	-118.28296	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 5 ON PLANS. CHANGES TO SINGLE LINE AND PANELS. LOAD UPDATE. NO ADDITIONAL LOADS NOTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54189	11041-10000-09750	800 S FIGUEROA ST	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM			PC Info Complete	05/12/2011 12:00:00 AM	ADDRESS	34.04771	-118.26116	ADDITION TO AN EXISTING FIRE ALARM SYSTEM.  OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54190	19041-20000-10329	20732 W BEECH CIR #304	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.29319	-118.58554	INSTALLATION OF A 3.02KW DC/2.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (9) SUNPOWER 335 BLK PV MODULES WITH INTEGRATED MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54191	18041-10000-27369	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.2215	-118.42999	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT, REMODEL OF 8 TOILET ROOMS, WORK INCLUDES REPLACEMENT OF PLUMBING AND LIGHTING FIXTURES - TOTAL AFFETED AREA = 1155 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54192	10041-10000-18086	6801 W HOLLYWOOD BLVD B-127	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	T-24 lighting plan check only for space B-127.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54193	18041-20000-17660	5525 N CASE AVE	91601	2	174B173  1166	2350003059	R4-1L	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Apartment			05/14/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	02/14/2022 12:00:00 AM	ADDRESS	34.17084	-118.37214	Plan check for Fire Alarm System for 6 story 98 units appartment and 240 devices and 1 FACP. B#17010-30000-02978	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54194	16041-20001-04897	8600 N GLENOAKS BLVD 1-60	91352	2	192B177    43	2404009013	(T)(Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.03	Electrical	Electrical	Apartment			10/28/2016 12:00:00 AM			PC Approved	10/28/2016 12:00:00 AM	ADDRESS	34.22667	-118.36307	10/28/2016 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the elevators and other items as marked.*****Previous Work Description*****Plan check for a power and energy. Project site is a new 3-story, 60-unit apartment building: 3 floors of residention over 1 level of basement parking garage. Servize size is 1600 amps. Total indoor lighting area = 40,390 sq. ft. and total outdoor lighting area = 5,029 sq. ft.Note: Building application has been generated under 15010-20000-04561	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54195	19041-20001-07353	5225 N BLAKESLEE AVE	91601	2	171B173   535	2350018084	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.16534	-118.37263	PLAN CHECK FOR NEW 254.88KW DC/228.74KW AC ELEVATED ROOFMOUNTED PV SYSTEM INSTALLED ON A EXISTING 5 STORY APARTMENT BUILDING. SCOPE OF WORK INCLUDES (708) ADANI SOLAR MODULES WITH (354) P730 SE OPTIMIZERS, (8) SE30KUS INVERTERS, (1) 500KVA TRANSFORMER, (1) NEW 2000A SERVICE, (1) 2000A MAIN PANEL, AND (1) 400A PV LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54196	15041-10000-12436	20101 S HAMILTON AVE	90502	15	054B197   127	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.84769	-118.28637	TI TO AN EXISTING BUILDING. PC FOR POWER AND ENERGY. TOTAL SQ. FT. 27658. FEES PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54197	16041-10000-13632	22738-22740 W VENTURA BLVD	91364	3	171B097   405	2040031045	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.16622	-118.62188	PC FOR ENERGY. T.I  FOR FIRE LOSS IN A BARBER SHOP. TOTAL AREA 1580 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54198	14041-20001-04065	22044 W RUNNYMEDE ST	91303	3	186B101   558	2023004003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.20542	-118.60761	Expedite Fee ONLY*****Roof mounted PV system with 5.5KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54199	11041-10000-26383	3210 INGLEDALE TER	90039										Electrical	Electrical	1 or 2 Family Dwelling			12/09/2011 12:00:00 AM			Reviewed by Supervisor	01/25/2012 12:00:00 AM				ROOF MOUNTED PV SYSTEM  FOR SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54200	18041-20000-17191	12283 N WINDMERE DR	91342	7	219B149   882	2507009***	(Q)RD3-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.2942	-118.45096	Plan check for solar PV roof mounted system. System size: 4.49kW with 13 AC Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54201	19041-10000-30864	700 E JACKSON ST	90012	14	130-5A217 320	5173015011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	02/06/2021 12:00:00 AM	ADDRESS	34.05095	-118.23318	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54202	19041-20000-41479	17341 W WENTZEL WAY	91344	12	222B133   164	2601019047	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.30633	-118.51076	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 7.82 KW DC/6.67 KW AC. SCOPE OF WORK CONSISTS OF (23) PV MODULES WITH MICROINVERTERS AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54203	18041-10000-18627	11668 W SHERMAN WAY 1st Flr	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM			PC Info Complete	05/18/2018 12:00:00 AM	ADDRESS	34.20103	-118.38683	Energy plan check for a laboratory T.I located on the 1st floor. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54204	18041-10000-09062	737 W 144TH ST	90247	15	075B197   256	6119018002	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	33.90112	-118.2889	Plan check for a utility own residential PV 2.8kw AC roof mounted system with (10) modules and mircroinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54205	18041-20001-35492	6930 N OWENSMOUTH AVE	91303	3	183B105   749	2138007007	(Q)P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM			Reviewed by Supervisor	09/27/2018 12:00:00 AM	ADDRESS	34.1965	-118.60139	Expedite per applicant requestPlan check for PV roof mounted system, system size: 17.39kW AC with 54 PV Modules and 1 inverter(14.4KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54206	15041-10000-05754	5161 N LANKERSHIM BLVD 3rd Floor	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.16452	-118.37469	Installation of lighting and receptacles in (N) corridor in (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54207	17041-10000-07970	1800 N VINE ST	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.10393	-118.3265	NEW FIRE ALARMS SYSTEM FOR AN EXISTING OFFICE BUILDING. SCOPE INCLUDES 67 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54208	15041-20000-00820	11030 N DE FOE AVE	91331	7	210B161   620	2536004020	R1-1	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.27006	-118.41202	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.44kW. Ungrounded system.16 EnPhase M215 microinverters with 16  250W pv modules on a single string.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54209	18041-20000-02291	5363 N BALBOA BLVD #100	91316	5	171B133    38	2258027016	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.16893	-118.50129	Medical office tenant improvement.consultation only.  Building permit application under 17016-40000-32208.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54210	14041-20000-34954	18555 W VENTURA BLVD	91356	3	174B125   543	2160007037	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	03/09/2015 12:00:00 AM		Issued	03/09/2015 12:00:00 AM	ADDRESS	34.1697	-118.53779	Plan check for power and energy. TENANT IMPROVEMENT TO RECENTLY REMODELED SHELL. Build out shell unit into a medical office. Wiring in patient care ares. New lighting system. 2,820sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54211	14041-20001-15212	835 N SEWARD ST	90038	4	141B185    96	5533024028	MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.08621	-118.33326	Modifications to approved set.  Changes to circuiting of emergency lighting and additional exterior accent lights.  (((CHANGE OF USE FROM INDUSTRIAL TO CREATIVE OFFICE AND SOUND STAGE.  PLAN CHECK FOR TITLE 24 PART 6 FOR CHANGES TO LIGHTING SYSTEM.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54212	10041-20001-15411	14731 W RAYEN ST	91402	6	195B149   247	2651012028	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Apartment			05/24/2011 12:00:00 AM			PC Approved	05/24/2011 12:00:00 AM	ADDRESS	34.23197	-118.45487	Plan check only. Delta 3 only. Reduce AIC of distribution board from 100K to 65K.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54213	18041-10000-12918	12734 W BRANFORD ST	91331	6	198B161    62	2629003***	(Q)MR1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Issued	04/10/2018 12:00:00 AM	ADDRESS	34.24234	-118.41092	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54214	18041-20000-10929	20332 W AETNA ST	91367	3	177B113   186	2149009002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.17864	-118.5765	PV1.  Install 5.4 kW roof mounted grid tied PV system.  (15) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54215	13041-10000-15942	3601 S WATT WAY GRADE FORD-HALL	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	07/09/2013 12:00:00 AM	ADDRESS	34.02113	-118.28752	GRACE FORD SALVATORI HALL (GFS) RENOVATION PROJECT AT USC;  DEMOLITION OF  INTERIOR FINISHES IN ROOMS 106, 134, & 135;  FIXED SEATING,, LIGHTING,  title 24 and emergency lighting. 1st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54216	11041-10000-26246	23734 W FITZGERALD ST	91304	12	189B089    27	2020010036	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.2175	-118.64515	New 4.59KW rooftop mounted photovoltaic system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54217	14041-10000-10120	1300 S ELECTRIC AVE	90291	11	108B145  1078	4239028008	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.99169	-118.4676	PLAN CHECK FOR POWER AND ENERGY. NEW SERVICES AND OUTDOOR LIGHTING. METHANE ZONE, HAZARDOUS LOCATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54218	15041-20000-01669	4414 N PETIT AVE	91436	5	165B137   106	2284010003	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.15108	-118.49541	New roof mounted PV system with Microinverter (Enphase M250) and Power one Inverter.  Total system size 9.72KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54219	19041-10000-45573	12746 W JEFFERSON BLVD # 1100	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	08/20/2020 12:00:00 AM		Permit Finaled	09/30/2020 12:00:00 AM	ADDRESS	33.97756	-118.41709	T-24 PLAN CHECK FOR A TI TO A PART OF EXISTING SPACE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. ROTAL AFFECTED AREA IS 568 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54220	19041-20000-32871	10359 N MT GLEASON AVE	91040	7	204B193   394	2559013012	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.25767	-118.30283	PV1. INSTALL (18) MODULES AND OPTIMIZERS WITH (1) SOLAREDGE 6.0 KW INVERTER. SYSTEM SIZE IS 5.76 KW DC AND 4.89 KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54221	10041-20000-09747	923 W 37TH PL 1-12	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM			PC Approved	05/24/2010 12:00:00 AM	PIN	34.02030756	-118.28890608	Remodeling mechanical and electrical room. This P/C is only title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54222	18041-10000-33313	8550 N BALBOA BLVD STE 195	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.22649	-118.5024	REPLACE INDOOR FLUORESENT TROFFERS WITH NEW LED RETROFIT KITS T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54223	17041-20000-02168	6339 N SUNNYSLOPE AVE	91401	2	180B157  1037	2330009028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.18601	-118.42701	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.11.52kW ungrounded system. (48) EnPhase M250 microinverters. (48) 275W pv modules.$0 permit fee per State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54224	10041-10000-23270	2029 S CENTURY PARK EAST 20th floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/19/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	02/18/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	Ti in an existing office building in Suite # 2010.   EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54225	14041-20000-17486	18555 W DEVONSHIRE ST	91326	12	204B125    99	2728028016	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Issued	06/27/2014 12:00:00 AM	PIN	34.25817975	-118.53780185	Plan check for energy only. New lighting in single story retail space. 8169 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54226	17041-10000-04299	2241 N HYPERION AVE 1-11	90027	4	148-5A205 237	5430010022	C1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Apartment			02/09/2017 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	03/31/2021 12:00:00 AM	ADDRESS	34.10131	-118.27345	Plan check for new 11 units appartemt building. 4 story building with subtarrenean parking and 800 A ServiceB#13010-10000-04524Fire alarm variance was filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54227	12041-10000-16643	13360 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15935	-118.42423	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54228	17041-10000-20564	6064 W HOLLYWOOD BLVD	90028	13	148-5A189 153	5545006030	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.10148	-118.32211	MUSIC SCHOOL TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54229	13041-10000-26133	17327 N AVENIDA DE LA HERRADURA	90272	11	141B117    15	4431013020	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.07957	-118.56289	PV1. INSTALL ROOFMOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. 2 STORY HOUSE. SYSTEM SIZE: 6.25 kW. TRANSFORMER LESS INVERTER. 25 TRINA SOLAR TSM 250P MODULES. 1 POWERONE AURORA PV1-6000 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54230	17041-10001-23326	11401 N PORTER RANCH DR BLDG 7	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	06/30/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 7 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 15 unit apartment with 1,200 amp 208 volt service.       Building 7 of 10.  Type II.       Building permit #17010-10000-02384	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54231	18041-10000-18665	523 W 6TH ST R525S	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM STORE TO RESTUARANT. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2261 SQ. FT. B#18016-10000-15858	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54232	18041-20000-25641	9418 W LA TUNA CANYON ROAD	91352	7	198B185   113	2401037004	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Issued	07/19/2018 12:00:00 AM	ADDRESS	34.2358	-118.33802	Plan check for PV roof mounted system, addition PV to existing system, new PV size: 9.31KW AC CECwith 36 modules and 36 microinverters. Total new + existing system size: 19.86KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54233	17041-10001-00489	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.20103	-118.38536	pc for changes to new set of plans. changes noted delta 3 on plans. addition of transformer to establish a 4 wire system for fuel cells.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54234	16041-10003-00290	1070 S BEDFORD ST 1-19	90035	5	132B169   448	4332021027	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			12/04/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.0573	-118.38026	"DELTA ""2"" & ""1"" CHANGES TO APPROVED PLANS ONLY. (Those clouds without ""2"" or ""3"" are not inluded). Changes are listed on Page E-1. (Location of service, feeder types & sizes, added and changed loads)<<<FULL PC FOR A NEW 19-UNIT APARTMENT BUILDING. TOTAL AFFECTED AREA IS 22661 SQ. FT.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54235	17041-20001-35954	17947 W VALLEY VISTA BLVD	91316	5	168B129   353	2182013016	R1-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM			PC Approved	10/14/2017 12:00:00 AM	ADDRESS	34.15817	-118.52358	expeditepv1install roof mounted pv system sized 10.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54236	12041-20001-29780	1654 N MANDEVILLE CANYON ROAD	90049	11	135B137   614	4426018030	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	34.0629	-118.49281	Original plans were in error. There are actually 11 modules per string with 3 strings. (plan check and permit is for 9 extra modules) No Other Changes.Photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54237	15041-10000-28255	8401 N VAN NUYS BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	ADDRESS	34.22308	-118.44896	PC FOR ENERGY. COMMERCIAL/ RETAIL BUILDING.T.I. RUE 21. TOTAL 6975 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54238	17041-10000-31855	7625 S CRENSHAW BLVD	90043	8	099B185   142	4012021005	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM			PC Info Complete	09/26/2017 12:00:00 AM	ADDRESS	33.97015	-118.33105	PC for T24 only for outpatient Veterinary clinic. Installing new 200 A panel, new circuits, lights, receptacles and equipment. Total area of 1771sqft. Building# 17016-10000-16231	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54239	17041-10000-28720	1516 N SAN PABLO ST	90033	14	135A225    64	5202004042	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM			PC Info Complete	09/26/2017 12:00:00 AM	ADDRESS	34.06268	-118.20282	PLAN CHECK FOR T24 ONLY T.I. FOR STARBUCKS COFFEE, SCOPE : INSTALL LIGHTS AND RECEPTACLES ONLY ON THE KITCHEN AND WORKROOM AREA: 446 SQ.FT.  ((B# 17016-10000-18917))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54240	13041-20000-28765	17339 W HALSTED ST	91325	12	201B129   358	2755008034	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.24492	-118.51295	New 4.2kw rooftop PV system for an existing single family dwelling.  System uses Enphase M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54241	13041-10000-18410	2715 N CARMAR DR	90046	4	156B169   457	5565041018	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.1199	-118.38191	ROOF-MOUNTED SOLAR ARRAY INSTALLATION, SYSTEM SIZED AT 13.72KW DC AND 11 KW AC, IN A TWO-STORY HOUSE. 2 INVERTERS, PVI-5000-OUTD-US, PVI-6000-OUTD-US, BOTH DC UNGROUNDED(TRANSFORMERLESS). MODULE SPECS TSM-245PC05/PA05.18. SUBMITTED BEFORE IMPLEMENTATION OF RSES FEE SCHEDULE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54242	16041-10000-25164	11322 W COVELLO ST	91352	2	186B173   415	2315016007	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Issued	07/18/2016 12:00:00 AM	ADDRESS	34.20743	-118.3777	PV1, rooftop solar installation. Total system size is 6.25 kW AC.   (25) Modules SW275,  and (25) microinverters Enphase M250	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54243	12041-20000-03510	8463 N AURA AVE	91324	12	192B117   331	2783003014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.22434	-118.55478	pv system transformerless 5.4 kw single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54244	15041-10000-10979	3335 S FIGUEROA ST UNIT G	90007	9	120A203   503	5123009042	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Closed	09/28/2015 12:00:00 AM	ADDRESS	34.02224	-118.28008	CHANGE OF USE FROM RETAIL TO MEDICAL FACILITY.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54245	16041-20001-09548	16901 W NAPA ST	91343	12	195B133   508	2689018032	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	05/05/2017 12:00:00 AM	ADDRESS	34.22679	-118.50046	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM.  TOTAL SYSTEM SIZE: 364 KW.   TWO BUILDING CONNECTED AS ONE FEED IN TARRIF SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54246	18041-10000-04518	12918 W RUBENS AVE	90066	11	105B157   485	4223007023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Re-Activate Permit	10/21/2019 12:00:00 AM	ADDRESS	33.98447	-118.42877	Plan check for battery back up power wall to existing PV roof mounted system. Total battery back up size: 13.5kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54247	19041-10000-06367	1609 W 25TH ST	90732	15	009B189   138	7563016018	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	33.72309	-118.31342	Plan check for T24 only, tenant improvement to (E) retail space to prepare core-and-shell retail space for future tenant.  New lights and power are fed from existing subpanel in the area. Total area under the SOW: 1,475 sq.ft(B# 19016-40000-04793)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54248	18041-20001-02543	6253 N AUCKLAND AVE	91606	2	177B177    96	2414019011	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM			PC Approved	02/08/2018 12:00:00 AM	ADDRESS	34.18453	-118.36062	expeditepv1install roof mounted pv system sized 3.8kw interconnected with msp.  this is an addition to an existing pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54249	12041-10000-13172	8513 S VERMONT AVE	90044	8	097-5A199 225	6033026026	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Approved	06/07/2012 12:00:00 AM	ADDRESS	33.9605	-118.292	Plan check T24 Energy for retail TI. Existing permit #12041-10000-06366.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54250	19041-10000-29378	7245 N LAUREL CANYON BLVD	91605	2	186B165   260	2307022010	(T)(Q)M2-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	34.20265	-118.3968	PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES TREATMENT PLANT ROOM TO AN EXISTING SERVICE.NEW LIGHTING AND RECEPTACLES  TOTAL SQ. FT. 5126.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54251	13041-10000-36132	555 W 5TH ST CONCOURSE-LEVEL	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Closed	07/12/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	TENANT IMPROVEMENT IN OFFICESON THE CONCOURSE LEVEL PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54252	12041-10000-30087	12541 W BEATRICE ST	90066	11	105B161   940	4211006026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM			PC Approved	03/01/2013 12:00:00 AM	ADDRESS	33.98116	-118.41478	12041-10000-30087permit to be pulled at PC only . T24 ONLY. TI OFFICE (MEDIA ART labs). 2 STORY. METHANE 6538SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54253	16041-20000-29600	13931 W POLK ST	91342	7	228B153   451	2503006018	RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.31909	-118.43699	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.25 KW.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54254	17041-10001-07716	4235 S REDWOOD AVE	90066	11	108B153  1232	4230006026	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	33.98872	-118.43837	PC only.  Recheck for lost set of wet stamps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54255	16041-10000-29148	1999 S AVENUE OF THE STARS 3300	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON SUITE 3300. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 12955 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54256	18041-10001-19185	1423 N TAMARIND AVE	90028	13	147A191   133	5545014014	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM			PC Approved	07/24/2018 12:00:00 AM	ADDRESS	34.09633	-118.31918	CHANGES TO AN APPROVED SET OF PLANS. CHANGES TO REFLECT AS BUILT. PLAN CHECKING FOR VOLTAGE DROP PER TITLE 24. (((((PLAN CHECK FOR T-24 ENERGY ONLY.CONVERT EXISTING 3 UNIT APARTMENT UNITS TO CHILD CARE (AGES 2-K).INSTALL A NEW 400 AMP SERVICE, 3 PANELS AND CIRCUTS & LIGHTS.PERMIT #'S: 18016-10K-00057, 18016-10K-00058, 18016-10K-10411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54257	18041-10000-07218	16444 W ROSCOE BLVD	91406	6	189B137     4	2205003906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21987	-118.49574	New Airplane Hanger and related offices in Van Nuys Airport. EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54258	18041-20001-38946	962 N SOMERA ROAD	90077	5	144B149   333	4369034012	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM			PC Approved	11/16/2018 12:00:00 AM	ADDRESS	34.08764	-118.45671	Expedite per applicant requestPlan check for PV roof mounted system, syste size: 13.86KW DC, 11.4KW AC with 24 PV modules and 1 inverter(11.4KW) connected to existing 600A  Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54259	15041-10000-06192	746 E 61ST ST	90001	9	105B205   596	6007009012	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	33.9843	-118.2616	IN A WAREHOUSE /STORAGE AREAS, RETROFIT EXISTING LUMINAIRES TO LED WITH RETROFIT KITSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54260	17041-20001-28497	14526 W HARTLAND ST	91405	6	183B149   674	2219025034	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.19496	-118.44984	12/30/19CHANGES TO APPROVED SET CHANGES TO SERVICE ROUTING FROM UTILITY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54261	17041-10000-02735	5750 S MESMER AVE	90230	11	105B165   299	4220015038	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	33.98373	-118.39868	Plan check for power only in existing building load exceed 400A install car lifts in dealership. Existing service, distribution panels. No lighing work is being done. B#16016-20000-18845	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54262	15041-10004-08987	380 W WORLD WAY TBIT/T4-CONNECTOR	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	12/25/16Changes to an approved set of plans. All changes made under delta 5. Scope includes separating fire alarm permits for T4 connector(380 w. World Way) and terminal 4(400 Wolrd way)  due to two different addresses.      NOTE: Fire alarm permit for terminal 4 is pulled under PCIS#16041-10000-05967(((12/22/2015Changes to an approved set of plans, note changes on delta 4. Changes include addition and removal of devices. ((8/6/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3. CHANGES INCLUDE REMOVAL AND ADDITION OF DEVICES.New fire alarm system (full evacuation) for Terminal 4 connector on levels 1-4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54263	17041-10000-10634	21725 W VICTORY BLVD	91303	3	180B105    77	2139004045	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.18791	-118.60217	Title 24 plan check.  T.I. to existing Nordstrom store.  New lighting and receptacles in 3 vignete shell spaces for future tenants.  Total area = 2,500 sq. ft.            Building permit #17016-10000-07927	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54264	12041-10000-11416	21255 W BURBANK BLVD 3RD FLR-CORRIDOR	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	08/29/2012 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT ON THE THIRD FLOOR OF A 6-STORY HIGH RISE BUILDING IN THE COMMON AREAS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54265	18041-10000-35563	10960 W WILSHIRE BLVD 14TH FLR.-CORRIDOR	90024	5	132B149   134	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM			PC Info Complete	09/18/2018 12:00:00 AM	ADDRESS	34.058	-118.44597	TI IN AN EXISTING CORRIDOR AND ELEVATOR LOBBY ON THE 14TH FLOOR.T-243 ENERGY ONLY. ELECTRICAL PERMIT: 18041-10000-34309BLDG PERMIT: 18016-10000-23993	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54266	19041-20000-12661	21026 W NASHVILLE ST	91311	12	210B105   175	2706003039	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.26887	-118.5916	Plan check for Tesla Power Wall installed into existing PV system. Install 2 Tesla Power Wall 2.0.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54267	16041-20000-31352	14006 W RIVERSIDE DR Suite 213A	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only. Project site is an existing tenant space within a commercial building. Project scope is a tenant improvement. Total lighting area = 795 sq. ft.Note: Building application has been generated under 16026-20000-00386	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54268	15041-20001-11261	3475 S CLARINGTON AVE 1-37	90034	5	120B165    64	4313001034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM			PC Approved	08/06/2015 12:00:00 AM	ADDRESS	34.02859	-118.40528	Expedite per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 20 kWac and consists of (93) modules, (93) micro-inverters, and (1) 200-amp load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54269	14041-10001-03875	2207 W 75TH ST	90043	8	102B189  1776	4009009023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	33.97198	-118.31813	"""EXPEDITED PER APPLICANTS REQUEST""PV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. POWER OPTOMIZERS. ONE STORY. SYSTEM SIZE: 4 KW DC.(16) CANADIAN SOLAR # CS6P-250PX(16) SOLAREDGE OP300(1) SOLAREDGE SE3800A"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54270	15041-10000-43581	8005 W FOOTHILL BLVD	91040	7	204B193   130	2556026017	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.25982	-118.30729	PC FOR ENERGY. TI FOR A FAST FOOD RESTURANT. ONE STORY BUILDING. TOTAL AREA 1194 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54271	15041-10000-30148	4505 S GLENCOE AVE	90292	11	105B153    96	4212007009	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	11/20/2015 12:00:00 AM	ADDRESS	33.98462	-118.43495	Ti, pc for energy only to an existing commercial 2 story bldg (offices). Scope of work: adding new branch circuits, lighting, receptacles and motors. Sq ft = 11350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54272	12041-10003-20762	1520-1520 1/2 S WESTERN AVE	90732	15	012B193   434	7560013045	R2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM			Corrections Issued	07/16/2013 12:00:00 AM	ADDRESS	33.72974	-118.31291	Plan check for 11KW roof mounted photovoltaic system. 2-family dwelling(((((((((((((((((((    7-16-13  UPGRADE SERVICE TO 400 AMPS, NEW PANEL AND TWO NEW SUB PANELS)))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54273	13041-10000-30491	200 S LOS ANGELES ST	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM			PC Info Complete	11/26/2013 12:00:00 AM	ADDRESS	34.05007	-118.2433	TI of leasing office on first floor of mixed-use apartment/retail building.  Newly connected load less than 400 A.  Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54274	12041-20000-12254	5200 N LANKERSHIM BLVD #200	90068	4	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM	05/30/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	PIN	34.16536072	-118.37437627	energy plan check # 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54275	19041-10001-05907	700 W 9TH ST	90015	14	129A207   333	5138017***	C2-4D-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.04579	-118.2618	PLAN CHECK ONLY FOR CHNAGES TO AN APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 3 AND DELTA 4, CHANGES IS SHOWING THE NORMAL AND EMRGENCY CIRCUIT FOR ALL EMERGENCY LIGHTING. ------------------------------------ORINGAL SCOPE OF WORK------------------------------------------------------CHANGE OF USE FROM RETAIL (CORE AND SHELLL) TO RESTAURANT IN A 28-STORY MIXED USE (RESIDENTIAL AND COMMERCIAL BLDG). PLAN CHECK FOR POWER & ENERGY. BULDING PERMIT: 19014-10000-00059	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54276	19041-20000-33751	6901 W SANTA MONICA BLVD	90038	4	144B181   392	5532017046	C2-1D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Closed	01/27/2023 12:00:00 AM	PIN	34.09154829	-118.34126757	1200A 480Y/277V  3ph-4w service and distribution for construction temp power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54277	17041-10000-41386	1330 N CORONADO ST	90026	13	141A207    78	5424021009	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.08198	-118.26711	Install new rooftop solar system, 5kW AC, (16) modules, (1) central inverter in a single-family dwelling.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54278	13041-10000-17165	16534 W LAS CASAS PL	90272	11	129B121   419	4419013066	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.04995	-118.54192	PV1.  Install 7.13 kW DC roof-mounted solar array, interconnect with main service panel.  {Microinverters: Enphase M215-60-2LL-32} {33 modules: Talesun TP660P240}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54279	18041-10000-13150	5865 S CAMPUS CENTER DR SOUND-STAGES	90094	11	102B161  1149	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	IN AN EXISTING AIRPLANE HANGER(1 OF 2), TWO SOUNDSTAGES ARE TO BE BUILT; THIS APPLICATION ARE FOR NEW CIRCUITS SUPPLIED FROM PANELBOARDS REVIEWED ON 18041-10000-13143	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54280	16041-10000-05375	1800 CENTURY PARK EAST 220	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	PIN	34.06270629	-118.4150769	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  SCOPE OF WORK 1970 SQFT IN SUITE 220.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54281	15041-10000-16214	2121 S AVENUE OF THE STARS 16 TH FL	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Apartment			05/28/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	ALTERATIONS IN CORRIDORS AND RESTROOMS ON THE 16TH FLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54282	15041-10000-31347	200 WORLD WAY SPACE 284-C	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	T-24, NEW KIOSK FOR CURRENCY EXCHANGE. ADDING NEW LIGHTING AND RECEPTACLES. PC FOR ENERGY ONLY. TOTAL SQ. FT. 122	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54283	14041-10000-27105	13237 W WEDDINGTON ST	91401	4	171B157   289	2345023002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.16679	-118.42156	Standard plan PV1, 6kw roof-mounted  system including (1) ABB PVI -6.0 inverter and (25) Kyocera KD255 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54284	13041-10007-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.10155	-118.31097	CHANGES TO APPROVED SET OF PLANS. CHANGES TO AIC RATING AND SERIES RATING COMBINATION FROM SUB DISTRIBUTION TO  RESIDENTIAL  UNIT BREAKERS. ALL CHANGES UNDER DELTA-7 . PC ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54285	14041-10000-11465	621 S WESTERN AVE	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.0628	-118.30928	IN AN EXISTING THEATER, INSTALLING PANEL BOARD TO SUPPLY BRANCH CIRCUITS TO POWERMOTORIZED LIFT MOTORS FOR PROJECTORS; TWO EACH METAL HALIDE LUMINAIRES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54286	16041-10001-30642	835 W JEFFERSON BLVD 7-C	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	34.02411	-118.28451	CHANGES TO APPROVED SET OF PLANS. REMOVAL OF RESTROOM. PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54287	16041-10000-12305	1224 E 21ST ST	90011	9	120A211   179	5131014013	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Expired	05/10/2018 12:00:00 AM	ADDRESS	34.02322	-118.25329	PV1 NEW ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS. (13) MODULES AND (13) MICROINVERTERS. TOTAL SYSTEM SIZE IS 3250.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54288	19041-10000-44812	1261 S STONER AVE 1-8	90025	11	129B145   887	4263008009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Apartment			11/01/2019 12:00:00 AM			Reviewed by Supervisor	11/20/2019 12:00:00 AM	ADDRESS	34.04711	-118.46065	NEW ROOF MOUNTED 8.96 KW (DC) PV SYSTEM WITH 32 PV MODULES WITH ENPHASE MICROINVERTERS ON AN APARTMENT BULDING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54289	10041-10000-11150	888 S FIGUEROA ST	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/11/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	08/19/2010 12:00:00 AM	ADDRESS	34.0465	-118.26225	title 24 and emergency lighting. high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54290	17041-30000-26189	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Closed	08/01/2018 12:00:00 AM	ADDRESS	34.0834	-118.37568	Plan check for T.I. retail existing space. Total area: 431 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54291	14041-20000-02579	4221 W BURNS AVE 1-28	90029	13	144A201   295	5539007021	RD1.5-1XL	Central	Hollywood	East Hollywood	YES	1914.10	Electrical	Electrical	Apartment			02/10/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.0878	-118.28523	EXISTING 28 UNIT APARTMENT. ALL ELECTRICAL IS NEW. 4 TYPICAL UNITS , TYPE 'A', TYPE 'B', TYPE 'C', AND TYPE 'D'. TWO STORY.NOTE: VARIANCE FILED ON 2/10/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54292	19041-10000-06946	10621 W VICTORY BLVD	91606	2	180B177    19	2412001***	A1-1XL	South Valley	North Hollywood - Valley Village	NoHo		1231.03	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.18686	-118.36296	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54293	18041-20000-00166	9011 S MAIN ST	90003	8	094-5A203 101	6040034004	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM			PC Info Complete	01/03/2018 12:00:00 AM	ADDRESS	33.95428	-118.27404	Plan check for power only. Project site is a new car garage. Project scope is a new service.Note: Building application has been generated under 17010-70000-03394.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54294	18041-10000-34767	13056 W SATICOY ST	91605	2	186B161   435	2303023042	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.20705	-118.41733	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54295	17041-20000-11240	7401 N SHOUP AVE	91307	12	186B101   532	2022019023	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Issued	07/03/2017 12:00:00 AM	ADDRESS	34.20486	-118.61489	TI to an existing school.  (2) services existing to remain - adding new panels AC, B1, B2, B3.  Plan check for power and energy.  Total square footage - 44565 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54296	14041-10008-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	PC FOR REARRANGEMENT OF PROJECTED LOADS. ALL LOADS PROJECTED AT THIS POINT IN TIME. ACTUALY LOAD SUBJECT TO METERING POST OCCUPANCY. THIS IS PC FOR APPLICANT REQUEST. CHANGES NOTED DELTA 28	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54297	16041-20001-02561	3883 S DEGNAN BLVD	90008	10	117B185   940	5033012023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.01508	-118.33014	Expedite per applicant request{{{{{{{Plan check for PV roof mounted system. System size: 3.8kW with 15 Canadian solar panels with 1 inverter(3.8kW)}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54298	12041-10000-17546	3200 E PIER B ST	90744	15	030B217    31	7440002286	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	33.77888	-118.22923	Plan check for installation of a liquid petroleum pipline metering system in an existing pipeline lateral connection. Existing service supplied from SCE Company. Equipment located in hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54299	15041-20000-00911	11414 W HATTERAS ST	91601	2	174B169   310	2338024014	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			01/12/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.17553	-118.37969	New fire alarms system for new 14 units apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54300	17041-10002-38945	5750 W HOLLYWOOD BLVD	90028	13	148-5A191 160	5586035002	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/09/2021 12:00:00 AM	ADDRESS	34.10154	-118.31491	PC FOR CHANGES TO APPROVED SET . All change under delta b, change include regroup resdeintial units, feeder and fault current and voltage drop will be changed, load calc will be recalculated. ((FULL PLAN CHECK FOR A 7 STORY MIXED USE BUILDING WITH 161 APARTMENT UNITS. BUILDING INCLUDES (2) 208/120V, 3ph,  2500AMP SERVICES FROM DWP. 7 TYPICAL UNIT LAYOUTS WITH 2 TYPICAL PANEL SCHEDULES. PLAN CHECK IN ACCORDANCE  WITH 2014 LAEC. HORIZONTAL EXIT IS PROVIED PER BUILDING PERMIT B#16010-10000-05275))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54301	19041-10000-01963	1541 N BUNDY DR	90049	11	141B137    17	4493029020	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM			Reviewed by Supervisor	01/22/2019 12:00:00 AM	ADDRESS	34.08581	-118.48569	INSTALLING 2 NEW TESLA ENERGY STORAGE BATTERIES. NO PV EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54302	16041-10001-17544	6256 N TOPANGA CANYON BLVD # 1350	91364	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM			PC Approved	06/21/2016 12:00:00 AM	PIN	34.1851785	-118.60468145	6/21/2016Title 24 only. Changes to approved set of plans Addition of a new light fixture. Total sq ft 2320Note changes under delta 4(((Tenant improvement of existing retail space. FIRST TIME TENANT. FULL PLAN CHECK. POWER AND ENERGY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54303	11041-10000-21891	1277 N WILCOX AVE	90038	4	144B185  1331	5533002066	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/18/2011 12:00:00 AM	ADDRESS	34.09413	-118.33125	T.I. to an existing office.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54304	18041-20000-21520	21443 W IGLESIA DR	91364	3	165A107    84	2190011030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Issued	06/08/2018 12:00:00 AM	ADDRESS	34.14775	-118.59751	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 4.2KVA WITH 11 MODULES (SC-B2 SERIES) AND 1 CENTRAL INVERTER (PVI-4.2-OUTD-US) WITH BATTERY BACK UP SYSTEM (POWER WALL)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54305	16041-20003-26775	327 S HOOVER ST 1-48	90020	13	136-5A201 207	5501022007	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.06799	-118.2845	"3.21.2017 - Plan check for changes to approved set. Reduce main to 200A, only change (clouded Delta 2).=====2.14.2017 - Delta 1 changes to an approved set of plans.  Changes include downsize (1) inverter to 8kw and reconnect to msp.====='0$ permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 40kW with 176 modules and 4 inverters(10.0kW) connected to MSP"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54306	16041-10000-30147	5714 N MATILIJA AVE	91401	2	174B153   490	2246023018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Expired	10/05/2018 12:00:00 AM	ADDRESS	34.17437	-118.43329	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.24kWdc / 6.72kWac.  SCOPE INCLUDES 21 ACMS, AND ONE 125A SUBPANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54307	19041-20000-52218	15503 W VENTURA BLVD 240,380-,390	91436	5	168B145   722	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	01/13/2021 12:00:00 AM		Permit Finaled	04/26/2022 12:00:00 AM	ADDRESS	34.15504	-118.4723	Plan check for power and energy for Medical equipment wiring according to 517 NEC, new lighting, new 600A distribution and newly connected load is over 400A. Total area: 9,713 sq ft. B#19016-20000-40318	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54308	18041-10000-02467	9927 N CANOGA AVE	91311	12	201B105    47	2747010036	[Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.25094	-118.59754	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 7000 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54309	13041-20000-04843	13730 W ROSCOE BLVD N. 2 MOB-RM M	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.22149	-118.43179	Plan check for energy and emergency lighting. conference room for Kaiser. Conference Room M in NOrth 2 MOB (Medical Office Building).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54310	18041-10002-42602	7722 W MELROSE AVE	90046	5	141B177   626	5527022027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.08355	-118.35817	SUPPLEMENTAL  DELTA 2 CHANGES. REMOVING DAYLIGHT SENSORS FROM MULTIPLE LOCATIONS AND ADDITION OF 3 CIRCUITS TO THE POWER AND LIGHTING PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54311	12041-10001-13835	12930 W RUBENS AVE PV1	90066	11	105B157   501	4223007021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2012 12:00:00 AM			PC Approved	09/17/2012 12:00:00 AM	ADDRESS	33.98426	-118.42914	SOLAR/(22) MODULES/5.610KW. Solar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.  System uses Enphase Micro-Inverters.  System is in a methane zone and has underground trenching.  (Permit is under main application.  Supplemental application is Plan Check Only.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54312	12041-10000-23730	10549 N COZYCROFT AVE	91311	12	207B109   517	2707010011	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.26235	-118.58229	Plan check for new 5.2KW roof mounted photovoltaic system for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54313	16041-10000-38523	523 W 6TH ST 5th Floor	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	RESTROOM UPGRADES. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54314	13041-10000-04149	9526 N JELLICO AVE	91325	12	201B129   408	2755006008	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	ADDRESS	34.24417	-118.51869	PV1 6.7KW ROOF-MOUNT STD PLAN. 33 modules (solar world sunmodule sw240poly). MICROINVM215-60-2LL-S22. single story	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54315	10041-10000-22680	17732 W MELVIN LANE	91325	12	195B129   337	2768012038	RA-1	North Valley	Northridge	Northridge South		1151.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2010 12:00:00 AM	01/27/2011 12:00:00 AM		Permit Expired	02/21/2013 12:00:00 AM	ADDRESS	34.23045	-118.52155	INSTALL A NEW 20KW PV SYSTEM IN A SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54316	14041-10000-16166	7872 N VAN NUYS BLVD	91402	6	189B149   646	2212028012	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.21445	-118.44622	"PLANCHECK FOR T24 ENERGY.   T. I. OF NEW ""GAP"" RETAIL STORE IN EXISTING RETAIL SPACE.  APPROXIMATED 10,000SQFT TAILORED METHOD.  T24 TO INCLUDE BOTH  AREAS. BUILDING PERMIT :14016-10000-11743 AND 14016-10000-11744"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54317	17041-10000-08078	2216 S PURDUE AVE	90064	11	123B153   108	4260018022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Issued	03/14/2017 12:00:00 AM	ADDRESS	34.03644	-118.44248	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 12500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54318	12041-20000-17449	18600 W DEVONSHIRE ST Site-Lighting	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.25704	-118.53922	Install new panel and circuits for site lighting.  The panel location is in the electrical room of the Use Car Building as shown on page E-2.1.  Plan checked for T-24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54319	13041-10000-00901	8928 N SEPULVEDA BLVD	91343	7	195B145   150	2654005037	M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.23317	-118.46736	INSTALLATION OF NEW CENTRAL STATION FIRE ALARM PANEL AND DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54320	16041-10000-43199	350 S GRAND AVE	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM			Ready to Issue	05/25/2017 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only existing space T.I. sandwich shop in high-rise Building. Total area: 896  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54321	13041-10001-09575	5453 W HOLLYWOOD BLVD SUITE D	90027	13	148-5A193 342	5544007***	C4-1VL, R3-1, [Q]C4-2D	Central	Hollywood	Greater Griffith Park		1904.02	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.10193	-118.30871	Supplemental for additional plan check hours.  This was created due to additional plan check hours incurred under 13041-10000-09575.  M.Z. Original Work Descirption: T24 energy plan check for a Starbucks remodel.  2052 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54322	10041-10000-16572	1220 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.05011	-118.22642	Solar voltaic system installed on the roof of the building.  Consists of 8 modules, 8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54323	15041-20000-21897	1973 N VAN NESS AVE	90068	4	150A191     8	5587016022	R1-1-HPOZ	Central	Hollywood	Hollywood United		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.10731	-118.31602	Plan check for PV roof mounted system. System size: 5.0kW with 18 modules and 1 inverter(5.0kW). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54324	15041-10001-40464	21215 W BURBANK BLVD #620-BLDG E	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM			Ready to Issue	04/19/2016 12:00:00 AM	ADDRESS	34.17353	-118.59268	PC FOR POWER ONLY TO AN EXISTING OFFICE HIGH RISE BUILDING ON THE 6TH FLOOR(SUITE 620 BLDG E).  FIRST TIME TENANT SPACE. SCOPE INCLUDES 3 NEW SUBPANELS, 1 NEW 175KVA TRANSFORMER, AND NEW LOAD EQUIPMENT. NOTE: PC FOR ENERGY WAS COMPLETED UNDER PCIS#15041-20000-40464.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54325	13041-20000-35419	10965 W WEYBURN AVE	90024	5	135B149   594	4363017009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.06239	-118.44756	Change of use from retail to restaurant.  New lighting.  Occupancy load is 52 per the applicant.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  INSPECTOR TO VERIFY THAT EMERGENCY LIGHTING COMPLIES WITH 1 FC AVERAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54326	18041-20000-34601	5630 W LA MIRADA AVE	90038	13	144B193   292	5536004033	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.09365	-118.31203	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54327	13041-20000-05391	5055 W WILSHIRE BLVD SPC# 500	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Info Complete	03/11/2013 12:00:00 AM	ADDRESS	34.06235	-118.34036	Plan check for energy and emergency lighting. Space #500. Broadway Fed. High rise commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54328	13041-10000-36330	19913 W MARTHA ST	91367	3	174B113   291	2153017019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.17348	-118.56639	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS W/ OPTOMIZERS. SYSTEM SIZE: 6.5KW DC.(26) TRINA SOLAR TSM-250(1) SOLAR EDGE SE 6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54329	16041-20002-15077	5971 W VENICE BLVD	90034	10	126B173   934	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	34.03865	-118.37272	[[ 11/9/16 CHANGES TO APPROVED SET. CHANGE TO THE INTERCONNECTION OF SOLAR FROM LINE SIDE TAP TO CONNECTING TO A FEEDER ON THE LOAD SIDE OF A DISTRIBUTION PANEL PER 2014 NEC. VARIANCE HAS BEEN SUBMITTED TO USE 2014 NEC IN LIEU OF 2011 NEC]]]]PV2.  INSTALLATION OF SOLAR SYSTEM ON CANOPY GARAGE. SYSTEM SIZE: 220 KW DC.BUILDING PERMIT # 16014-20000-01949Note: Fees $0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54330	15041-20000-29702	10739 W STALLION RANCH ROAD	91040	7	204B177   260	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.25715	-118.36484	Plan check for PV ground mount System in a single family dwelling. System size: 20.0kW with 80 modules and 80 micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54331	19041-10000-36296	9816 W LA CANADA WAY	91040	7	207B181   208	2549024011	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.26189	-118.34584	$0 FEE PER AB1414. Plan check for a PV1 14.4KW AC / 18.3KW DC roofmounted system. Scope includes (1) subpanel, (2) inverters, (62) modules and optimizers interconnecting through the service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54332	10041-20000-02070	4760 W PICO BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.04831	-118.33938	PLAN CHECK POWER AND ENERGY FOR RALPHS MARKET REMODEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54333	12041-20000-24268	500 W WORLD WAY NORT SPACE 5G-F	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	"TERMINAL 5 / SPACE 5G-F. tenant improvement of existing restaurant. full plan check for power and energy for ""ford la times"", a new restaurant at LAX terminal 5G-F. 1236 SF"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54334	15041-10000-22097	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	NEW SERVICE FOR EDUCATIONAL RESEARCH FACILITY.  THIS APPLICATION IS FOR ROUGH FEES ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54335	13041-20000-19108	3187 S ALAMEDA ST	90058	9	115-5A215  12	5117017015	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.01068	-118.23993	RENOVATION OF EXISTING OFFICES. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 3950 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54336	14041-10000-02668	8019 N LEMONA AVE	91402	6	189B145   258	2209019008	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			Reviewed by Supervisor	02/11/2014 12:00:00 AM	ADDRESS	34.21663	-118.46025	PV1, Install 3 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3000A-US-ZB-U. (12) Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54337	12041-10002-30236	5867 S CENTRAL AVE	90001	9	108B209  1458	6007003900	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.98775	-118.25672	Delta-7 changes to approved set.  Single tenant space split into two separate retail spaces.  Additional panel for newly created space and additional loads (for #210).  (((New single story retail building.  New service, new panels, new ckts.  Full plan check.  Core and shell only.  No tenant build out.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54338	15041-20001-05056	12354 W TIARA ST	91607	2	177B165   890	2340007003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.17824	-118.4026	"""EXPEDITED PER APPLICANTS REQUEST ""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 21.84 KW DC.(84) KYOCERA # KU2606XPA(1) FRONIUS IG PLUS A 7.5(1) FRONIUS IG PLUS A  10"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54339	15041-20000-24360	15471 W DICKENS ST	91403	5	168B145   892	2283016024	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.15383	-118.47158	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54340	14041-10000-00166	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Closed	11/02/2016 12:00:00 AM	ADDRESS	33.93845	-118.42964	pLAN CEHCK FOR TEMPORARY CRUSHER AT lAX, PLAN CHECK FOR SERVICE/BOARD  FEEDING CRUSHERS WAS APPROVED UNDER 13041-10000-32206.  CRUSHER IS INSTALLED FOR PERIOD OF TIME ( 6 MONTHS TO 1 YEAR).  CRUSHER TO BE HANDEL UNDER SPECIAL EQUIPMENT INSP3ECTION PER INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54341	13041-10000-06153	10000 W SANTA MONICA BLVD	90067	5	135B161    35	4319001001	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Closed	04/21/2017 12:00:00 AM	ADDRESS	34.06351	-118.41446	TEMPORARY POWER FOR A 40-FLOOR HIGH RISE CONSTRUCTION PROJECT.  2 CRANES AND MULTIPLE TEMPORARY POWER SKIDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54342	14041-10000-09381	1627 S CRESCENT PL	90291	11	108B145  1276	4241013009	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	33.99103	-118.46204	PV1 ROOF MOUNTED MICROINVERTER. SERVICE SIZE 400A. TOTAL SYSTEM SIZE 8.0KW. No WEEB for bonding (Burndy lugs to be used instead) and equipment to be fully rated for 22KAIC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54343	13041-10000-09970	1536 N HIGHLAND AVE	90028	13	147A185    15	5547020046	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.09911	-118.33847	fire alarm system on first floor. new system including panel and 43 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54344	18041-30000-11052	14751-14761 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.17767	-118.45487	Plan check for Title 24 only in existing space lighting and receptacle in restroom and outdoor lighting. Total area: 6,140 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54345	18041-10000-13523	21600 W NORDHOFF ST	91311	3	195B105     7	2779018038	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.23525	-118.60067	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54346	15041-10008-14660	1002 W CHILDS WAY 4TH FL	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	34.02201	-118.28947	REVISIONS OF THE LIGHTING AND POWER IN A LABORATORY  AND OFFICES ON THE 4TH FLOOR.EXISTING EMERGENCY LUMINAIRES AND EXIT SIGNS TO REMAIN. TITLE 24 SHEETS ARE UPDATED PLAN CHECK ONLY. LEV4 AREA A REGIONS 2 & 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54347	16041-20001-28110	11276 N HERRICK AVE	91331	7	210B161   101	2533008018	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM			PC Approved	08/19/2016 12:00:00 AM	ADDRESS	34.27522	-118.41895	EXPEDITE PER APPLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MAP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54348	19041-10000-33997	1771 W BLAKE AVE BLDG 2	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Corrections Issued	10/01/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	2 OF 11. BLDG 2POWER PLAN CHECK FOR 1200A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDING AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54349	13041-20000-15390	10132 N WYSTONE AVE Pv-1	91324	12	204B121   306	2729003037	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.25484	-118.54682	PV-1. MIcroinverter plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54350	15041-10000-31583	353 S BROADWAY STE 200	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.04991	-118.24934	T-24. PC FOR ENERGY ONLY. TI  UNIT #200 ON EXISTING 6 STORY COMMERCIAL BUILDING (OFFICE). SCOPE INCLUDES NEW LIGHTING AND ONE NEW PANEL. TOTAL AREA IS 1944 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54351	11041-10000-26823	18223 W CHARLTON LANE	91326	12	213B125   126	2870018013	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2011 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.28292	-118.53088	PLAN CHECK 10.56KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54352	17041-20000-35537	2910 S 12TH AVE	90018	10	120B185    27	5051025003	R2-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Apartment			10/04/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.02899	-118.33153	fire sprinkler monitering system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54353	19041-20003-03586	12919 W SATICOY ST	91605	2	186B161   432	2303021012	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.20689	-118.41507	SUPPLEMENTAL PERMIT FEES PER INSPECTOR'S REQUESTCHARGING FOR ADDITION OF 12 BRANCH CIRCUITS AND 90 EXSISTING UNITS PER APPLICANT'S REQUEST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54354	10041-10000-06421	22159 W SHERMAN WAY	91303	3	183B101    60	2023009012	C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	04/22/2010 12:00:00 AM	ADDRESS	34.20119	-118.61014	fire alarm sysstem for care home.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54355	19041-20001-09620	8809 N ENFIELD AVE	91325	12	195B129   332	2768008006	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.23054	-118.52475	04/01/2019 Changes to an approved set of plans. PV module mounting details have been revised. System size and equipment has remained the same.*****Original Work Description*****INSTALLING A 12.87KW DC/10KW AC ROOFTOP PV SYSTEM. SCOPE OF WORK INCLUDES (1) SE10000 INVERTER, AND (39) PANASONIC 330W PV MODULES WITH P400 OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54356	11041-10001-08695	10850 W PICO BLVD #M2	90064	5	126B157  1663	4256001025	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Expired	09/09/2013 12:00:00 AM	ADDRESS	34.03983	-118.42857	REVISED SINGLE LINE DIAGRAM-NEW PANEL HC SUPPLIES THE TRANSFORMERS; CONNECTED LOADS REMAIN THE SAME(((((((((((Install new panels and branch circuits.  Plan check for power only.Note:  Lighting plan check approved under 11041-20000-07866	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54357	16041-10000-16347	359 W 42ND ST	90037	9	114A203    83	5111006022	RD2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Expired	06/12/2018 12:00:00 AM	ADDRESS	34.00752	-118.27975	PC FOR PV SYSTEM. TOTAL 5KW AC USING 23 MODULES. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54358	11041-10000-01376	8500 W BEVERLY BLVD # 684	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	06/27/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT IN RETAIL STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54359	14041-20000-35882	5048 N SHIRLEY AVE	91356	3	171B117   452	2175033007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.16233	-118.55683	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGE OF (2) INVERTERS FROM SUNNY BOY 80.KW AND 10.0KW INVERTERS TO FRONIUS 7.5KW AND 10.0KW INVERETRS. MASTER PERMIT UNDER 14041 20000 31034. ((PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 19.6 DC.(60) SUNPOWER 327W(1) SMA SB8000TL(1) SMA SB10000TL))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54360	17041-10000-30679	333 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   594	2424044021	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.13838	-118.35964	OFFICE TI, NEW LIGHTING. PC FO T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54361	13041-10000-21959	317 S BROADWAY #A7-#A8	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/14/2013 12:00:00 AM	ADDRESS	34.05069	-118.24861	TITLE-24, TENANT IMPROVEMENT FOR EXISTING RESTAURANT; TWO SPACES(BOTH RESTAURANT BEFORE) ARE BEING COMBINED TO ONE BIG SPACE FOR A TO-GO  RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54362	18041-20000-02499	21820 W BURBANK BLVD #301	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.17228	-118.6032	PLAN CHECK ONLY FOR TITLE 24 FOR TENANT IMPROVEMENT TO THE (E) OFFICE SPACE. INSTALL NEW PARTITIONS,  MILLWORK AND FINISHES. TOTAL NEW ADDED LOAD <400A. AFFECTED AREA 4332 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54363	14041-10000-26342	4670 W 62ND PL	90043	8	105B177   399	4002026008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Expired	10/18/2016 12:00:00 AM	ADDRESS	33.98267	-118.3578	PV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 6.375 KW DC.(25) TRINA SOLAR 255(1) POWER-ONE # AURORA PV1 6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54364	12041-10001-23664	560 N WESTERN AVE	90732	15	018B193     7	7446001901	OS-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00, 2964.00	Electrical	Electrical	Public Safety Only			06/18/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	ADDRESS	33.7478	-118.30907	This is rec park, the only changes are, service, and two new distribution boards. ((((((((((((((((((((((((((( changes made to previously approve set.  addition of pump, lighting control panel, separate feed to xformer.)))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54365	16041-10000-19316	4652 W HOLLYWOOD BLVD	90027	13	147B197   438	5542014005	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.10028	-118.29085	PC FOR ENERGY. CHANGE OF USE FROM PRINT SHOP TO MUSIC SCHOOL.  TENANT IMPROVEMENT .  CONNECTED LOAD LESS THAN 400 A. TOTAL AREA 1694.9 SQ FT. B # 15016-10000-23881	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54366	16041-10000-14029	10561 W PICO BLVD	90064	5	126B157   249	4315005003	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.04431	-118.42087	PC FOR POWER AND ENERGY TO AN EXISTING RETAIL BUILDING. EXISTING BUILDING IS BEING REMODELED AND GUTTED (CORE AND SHELL). SCOPE INCLUDES ADDING A NEW 600A 120/240 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, ONE NEW 200A SUBPANEL, AND ONE NEW 600A SUBPANEL. TOTAL AFFECTED AREA IS 8807 SQ. FT.  PLANS RESUBMITTED AS SUPPLEMENTAL  16041-10001-14029 WITH SIGNIFICANT CHANGES PRIOR TO APPROVAL.  APPROVED SET OF PLANS IS UNDER SUPPLEMENTAL.Stamp on plan show the master and supplemntal application number	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54367	11041-10000-14246	16450 W VANOWEN ST	91406	6	180B137    26	2231006051	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.1937	-118.4921	T.I  Exisitng 7-11 store.  Replacing the florecent light fixtures for LED in the retail floor area.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54368	14041-10001-08573	911 S LUCERNE BLVD	90005	4	132B185   557	5090021015	R2-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			Corrections Issued	06/18/2014 12:00:00 AM	PIN	34.05748112	-118.3270089	EXPEDITED RSES PLAN CHECK PER A PPLICANT REQUEST.{{PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(19) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54369	11041-20000-22145	11835 W SOUTH PARK AVE	90066	11	111B157   581	4233011006	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2011 12:00:00 AM			PC Approved	11/21/2011 12:00:00 AM	ADDRESS	33.99997	-118.42154	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.  An express permit was pulled for the the items listed in this plan check.  The permit number is 11041-20000-21894	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54370	15041-20000-29963	9124 N CLAIRE AVE	91324	12	198B121   721	2762035012	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.23634	-118.55023	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (1) combiner, and (34) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54371	17041-10000-38673	1461 1/2 W SUNSET BLVD	90026	13	139-5A211 161	5406001043	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.07539	-118.25374	Change of use to take-out restaurant; permit was obtained on separate applicationUNDER 17041-10000-36584THIS IS PLAN CHECK ONLY!!!PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54372	17041-20000-05536	8641 N GLENOAKS BLVD	91352	6	195B177   480		(Q)R3-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Apartment			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.22733	-118.36433	Plan check for power only. Replace 600A main service panel due to fire damage. All feeders and unit panels existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54373	14041-10000-16977	1925 S CENTURY PARK EAST SUITE #420	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. SUITE #420.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54374	19041-10000-41290	3020 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.01664	-118.21526	FULL PC FOR A TI IN A COMMERCIAL SPACE. SCOPE OF WORK INCLUDES ADDING SUBPANELS, A NEW 400A SWITCHBOARD AND REFRIGATION EQUIPMENT TO AN EXISTING ELECTRICAL SYSTEM. TOTAL CONNECTED LOAD IS OVER 400A. TOTAL AFFECTED AREA IS 32,664 SFQT. NOTE THERE ARE FOUR EXISTING SERVICES IN THIS ELECTRICAL SYSTEM. B#19016-10000-29988	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54375	13041-10001-31540	9714 N VALJEAN AVE	91343	12	201B137   564	2677015016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.24696	-118.48704	Expedited RSES plan check per applicant request.(((PV1, Install 6.75 kW DC roof-mounted solar array for a 1-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 27 modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54376	18041-10000-22138	7422 W 80TH ST	90045	11	099B157   286	4114014017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	33.96364	-118.42711	NOTE: PERMIT FEES ARE REDUCED DUE TO SENATE BILL 1222.INSTALL A 11.375 (DC) KW, 10.46 (AC) KW, WITH 35 SOLAR MODULES ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54377	17041-30000-07322	2005 S MAGNOLIA AVE	90007	1	126B197  1080	5056029005	[Q]R4-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Issued	03/16/2017 12:00:00 AM	ADDRESS	34.0379	-118.28736	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (36) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54378	19041-10000-09842	321 S FICKETT ST 1-16	90033	14	126A223   131	5180005027	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Apartment			03/19/2019 12:00:00 AM	07/28/2021 12:00:00 AM		Issued	07/28/2021 12:00:00 AM	PIN	34.03984547	-118.20929096	FULL PC FOR 800 amp 120/240 3 PHASE SERVICE WITH A TOTAL  AREA OF 7000 SQFT.  B#18010-20000-03215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54379	18041-10001-47188	6500 W WILSHIRE BLVD 17TH FLR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.06371	-118.3703	"DELTA ""4"" CHANGES TO THE APPROVED PLANS FOR ADDITIONAL ""EXIT"" SIGNS ON THE 17TH FLOOR.<<<PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT OF ENTIRE 17TH FLOOR <EXISTING OFFICE BUILDING.>. TOTAL AREA: 15,902 SQ.FT((B# 18016-10000-35164))>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54380	14041-10000-34632	2216 W COLORADO BLVD	90041	14	162A221   110	5686002027	[Q]C2-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	03/11/2015 12:00:00 AM		Issued	03/11/2015 12:00:00 AM	ADDRESS	34.13897	-118.21504	TI to (e) starbucks.  Plan check for energy only.  Permit to be pulled at EPC counter only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54381	13041-10000-35412	9901 N WYSTONE AVE	91324	12	201B121   117	2729005018	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.2503	-118.54723	PV1, Install 6.25 kw DC roof-mounted solar array, interconnect with main service for a one story house. (1)Transformerless inverter(s): SOLAREDGE SE 6000A-US, (25)Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54382	17041-10001-18426	816 S FIGUEROA ST ste 200	90017	14	129A207   173	5144021035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	34.0474	-118.26148	Supplemental PC for T24 only. Adding lighting fixtures in hallway area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54383	19041-10000-23579	4075 S LINCOLN BLVD	90292	11	108B149  1588	4229005040	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	33.98863	-118.4463	Energy plan check for removing HID fixtures and replace with new LED fixtures in a commeical building with a total lighting area of 2345-SQ FT. (in/outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54384	19041-20000-50913	11764 W CANTON PL	91604	2	159B169   304	2377020006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.13338	-118.39037	Plan check for PV roof mounted system, PV system size: 12.285KW with 39 PV Modules and 2 inverters(5.0KW) with 2 Energy Storage System Tesla PowerWall 2.0. Total Energy Storage System size: 27KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54385	15041-20002-36704	11505 N VIMY ROAD	91344	12	213B129   228	2601037045	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.28018	-118.52193	12.16.2015 - Plan check for changes to approved set. Moving inverter from exterior wall to inside of garage. Adding 20A fused DC disconnect to exterior wall. Changes clouded.[PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.4KWac. (36) MODULES-SUNPOWER SPR-E20-327(36) OPTIMIZERS-SOLAREDGE P400(1) CENTRAL INVERTER-SOLAREDGE SE11400A-US ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54386	17041-20001-18438	22801 W ROSCOE BLVD Bldg. 2	91304	12	192B097   578	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.22014	-118.62547	Changes to approved set of plans - changes include addition to lighting system, electrical equipment, addition panels, load redistribution. changes noted under delta 5, 6, 7, 8 only.  Original permit(((Change of use from educational institution to medical reserach office (non-clinical).  Plan check for power and energy.)))  BUILDING PERMIT ISSUED UNDER 16016-10000-27352	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54387	16041-10000-07938	333 S ALAMEDA ST # 109	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.04448	-118.23824	PC FOR T24 ONLY. T.I.FOR 3 STORY BUILDING IN SHOPPING MALL. TOTAL ARAEA 1020 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54388	17041-20000-01588	13025 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.18799	-118.41664	"new 1200 amp service upgrade.  reconnect existing distribution boards ""DB1"" and 'DB2"".  plan check for power only."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54389	17041-10000-31216	1553 N SCHRADER BLVD	90028	13	148-5A187 334	5547018029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.09953	-118.33258	PC for T24 only for removal of outdoor HID fixtures and replace with new LED fixtures.Total area 29725sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54390	19041-10000-28566	1630 W SEPULVEDA BLVD	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	ADDRESS	33.81654	-118.30809	PC for New service for starbucks 600A,208/120V,3ph,4w.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54391	15041-20002-04509			5	117B161   645	4252025007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	PIN	34.01728852	-118.41188377	12/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Feeder sizing has been modified as indicated and a unit has been removed. 11/23/15 Changes to an approve set. Changes made under cloud/bubble. Scope includes adding two new panels and branch circuits.  Loads for panel 'hp' is distributed to the two new panels to comply with disaggregation of the loads (hvac/plumbing/lighting). permit under pcis#15041-20000-04509((((PLANCHECK FOR POWER AND ENERGY FOR NEW APARTMENT BUILDING . FIFTEEEN UNITS. 18 PARKING SPACES IN SUBTERRANEAN GARAGE 4 STORIES W/ ROOF DECK. FIRE ALARM VARIANCE HAS BEEN SUBMITTED.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54392	19041-20000-37309	611 W 82ND ST	90044	8	099B201  1121	6032024022	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.10	Electrical	Electrical	Apartment			09/18/2019 12:00:00 AM	07/09/2020 12:00:00 AM		Permit Finaled	04/24/2023 12:00:00 AM	ADDRESS	33.96442	-118.28461	1000A 240/120V 1ph-3w service, distribution equipment, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54393	19041-10000-05946	8500 W BEVERLY BLVD 111	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	FULL PLAN CHECK FOR - T.I. FOR RESTAURANT IN SHEL SPACE WITHIN A COVERED MALL. WORK INCLUDES (N) CEILING, (N) FLOORING AND FOUNDATION, (N) INTERIOR, (N) LIGHTING - TOTAL NEW CONNECTED LOAD IS APPROX 250A WITH TOTAL AFFECTED AREA = 2959 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54394	16041-20000-28991	21300 W VICTORY BLVD Suite 630	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check for energy only. TI to existing office (suite 630) in high rise building. New lighting (incl. emergency) and receptacles. 1,434sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54395	15041-10000-34083	6562 W HOLLYWOOD BLVD	90028	13	148-5A187 189	5547015017	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.10141	-118.33308	T-24, CHANGE OF USE FROM A RETAIL TO OFFICE SPACE IN AN (E) BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACELS. TOTAL SQ. FT. 2731	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54396	18041-20000-36342	20829 W SPRUCE CIR	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.29532	-118.58782	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54397	13041-20001-23226	9458 N RUFFNER AVE	91343	12	198B137    65	2687015018	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.24269	-118.49693	EXPEDITE FEES.<<<<New ungrounded PV system with two inverters.  Rooftop, single family dwelling.  Plan check is for PV System only, NOT for Service upgrade or derating of main breaker.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54398	19041-10000-11370	1640 W 9TH ST	90732	15	015B193   393	7560002004	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	33.73667	-118.31306	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54399	15041-20001-10048	12460 W OSPREY LANE Unit #2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	Expedite per applicant request((((Plan check for PV roof mounted system for tri-plex unit #2 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10046)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54400	17041-20001-14123	7767 N JAMIESON AVE	91335	12	189B129  1064	2120007013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.21184	-118.52157	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.325 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54401	11041-20000-12100	10201 W PICO BLVD BLDG#95	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM			Corrections Issued	06/19/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check power for new substation Building #95 FOX Chiller Plant Upgrade	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54402	13041-10001-30147	2651 W IVANHOE DR	90039	4	150A207   157	5439011009	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM			PC Approved	11/20/2013 12:00:00 AM	ADDRESS	34.10537	-118.26339	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54403	13041-20000-16379	15871 W MULHOLLAND DR	90049	5	159B141   390	4490001009	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.12917	-118.47917	FULL PLAN CHECK FOR POWER AND ENERGY FOR EXISTING SCHOOL. TOTAL NEW LOAD EXCEEDS 400 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54404	10041-10000-16266	5151 W WILSHIRE BLVD	90036	4	135B181   919	5507022016	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Public Safety Only			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	08/24/2011 12:00:00 AM	ADDRESS	34.06244	-118.34233	INSTALLATION OF A SPRINKLER / CENTRAL STATION  MONITORING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54405	17041-30000-42271	1226 S BEDFORD ST # 1-20	90035	5	132B169   917	4332022041	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			11/21/2017 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	11/09/2022 12:00:00 AM	ADDRESS	34.05485	-118.3804	Paln check for new appartment NEW 20- UNIT , FIVE -STORY APARTMENT BUILDING OVER. 1200 A. Total area: 14959 sq ftB#15010-10000-04477	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54406	17041-10000-31159	2833 1/2 N HYPERION AVE	90027	4	151-5A205 135	5433027030	C4-1D	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			PC Info Complete	08/30/2017 12:00:00 AM	ADDRESS	34.10899	-118.27179	PC FOR  TAKE OUT COFFEE SHOP(CHANGE OF USE FROM RETAIL)  FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS, EQUIPMENT AND RECEPTACLES. TOTAL AFFECTED AREA 650 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54407	17041-10000-23468	1025 W 34TH ST	90731	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Closed	09/20/2017 12:00:00 AM	ADDRESS	34.02471	-118.28835	COFFEE STAND IN STUDENT SERVICES BUILDING. STARBUCKS. PC FOR T24 ENERGY ONLY. CHECKING LIGHITNG UPGRADES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54408	12041-20000-30369	929 S BROADWAY	90015	14	127-5A209 256	5139003005	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.04174	-118.25687	"600 amp ""Temp Power"" for a hotel.  New 75kva transformers and subpanels.  Site is in a Methane Zone"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54409	19041-10000-50151	17840 W PORTO MARINA WAY	90272	11	126B117   338	4416015060	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	06/19/2020 12:00:00 AM	ADDRESS	34.04199	-118.56405	[EPLAN] NEW PV1 ROOF MOUNTED INSTALLATION WITH SYSTEM SIZE OF 7.56KW DC/ 7.6KW AC, 24 MODULES (HANQHA Q-CELLS 315W), ONE CENTRAL INVERTER (SOLIVIA 7.6TL), ONE ESS (TESLA POWERWALL) CONNECTED TO A LOAD CENTER RATED AT 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54410	13041-20000-17020	6217 N CALVIN AVE	91335	3	177B117   357	2131018006	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.18306	-118.55574	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.55 KW. USING 2 INVERTERS TRANSFORMERLESS. USING 30 MODULES. ROOF MOUNTED. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54411	14041-10000-29154	1800 S AVENUE OF THE STARS Suite 120	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.06095	-118.41786	Energy plan check for a finanical office T.I . total area covers 1557 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54412	14041-20001-06413	10450 N DE SOTO AVE	91311	12	207B109   628	2706015033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.26047	-118.58835	(((expedite fees))pv1 single family dwelling. total system size 9.8kw ac using 46 microinverters. nonstandard plan. interconnection to 400A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54413	19041-20001-51026	5854 N TAMPA AVE	91356	3	177B117   821	2156004032	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	02/12/2020 12:00:00 AM	ADDRESS	34.17735	-118.55326	Expedited plan check fee.PV1l  Install 13.5 kW roof mounted PV system with 9.8 kWh energy storage system.  (37) modules with 3.8 and 7.6 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54414	13041-10003-07819	1529 E PLEASANT AVE 1-3	90033	14	129A221    57	5174021035	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Apartment			03/21/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	34.04894	-118.2212	03/21/16Changes to an approved set of plans. All changes are made under delta 1. Changes include replacing/removing outdoor lighting fixtures, and replacing feeder circuit breakers. NOTE: PERMIT PULLED UNDER PCIS#13041-10000-07819((((T24 FOR NEW 3 STORY APARTMENT BUILDING TOTAL CONNECTED LOAD LESS THAN 400A. INDOOR AND OUTDOOR LIGHTING. TOTAL SQRFT FOR OUTDOOR: 3995 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54415	17041-10000-03329	23001 W ROSCOE BLVD	91304	12	192B097   581	2005002901	A1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.21953	-118.62822	PROVIDING NEW DISTRIBUTION BOARD TO BYPASS 2 UPS STATIONS. NO ADDED LOADS AND NO OTHER CHANGES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54416	19041-30001-03490	1736 S SEPULVEDA BLVD	90025	5	129B153   950	4323020035	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.04663	-118.44316	03/28/2019 Changes to an approved set of plans. Lighting fixtures have changed and Title 24 forms have been updated. Lighting controls have been updated. *****Original Work Description*****Plan check for energy only. Project site is an existing commercial building. Project scope is a change of use from animal hospital to print shop on the first floor. Total lighting area = 7,035 sq. ft.Note: Building permit has been issued under 17016-10000-05216	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54417	18041-20000-29008	7536 N WOODLEY AVE	91406	6	186B141   163	2206019003	C1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Issued	09/11/2018 12:00:00 AM	ADDRESS	34.2077	-118.48347	Plan check for service upgrade to 600A  1 phase 3 w feeding 6 spaces, 2 existing panel and 5 new panels. B#17016-20000-03821	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54418	15041-20001-33986	10948 N HILLHAVEN AVE	91042	7	210B197   416	2553018013	RE9-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.26839	-118.28803	**Expedite FeePV1, Install (1) inverter and  (16) new roof mounted PV modules and connect to (E)(30) modules, system has optimizer for the entire system. New system total 13.8 kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54419	17041-20000-36495	515 S FLOWER ST 18TH- 19TH-FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT FOR OFFICES ON THE 18TH AND 19TH FLOOR OF A COMMERCIAL HIGHRISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54420	12041-10000-23363	5600 N VAN NUYS BLVD	91401	2	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.17244	-118.44837	central station monitoring system , one story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54421	15041-10000-29929	9000 N WINNETKA AVE	91324	12	195B113    40	2782037004	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.23374	-118.57085	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERICIAL BUILDING (RETAIL & WAREHOUSE). SCOPE INCLUDES REPLACING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AREA IS 21980 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54422	19041-10001-07561	7201 S SAN PEDRO ST	90003	9	102B205   874	6022009029	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	33.97452	-118.26972	PLAN CHECK FOR CHANGES TO APPROVED SET AND TO COVER UNCHECKED/UNPERMITTED SCOPES. THIS PLAN CHECK TO COVER AND INCLUDE ALL PREVIOUS APPLICATIONS (18041-10000-16739, 19041-10000-42889 AND 19041-10000-07561) IN ADDITION TO ANY CHANGES FOR FINAL INSPECTION.PERMIT FEES TO INCLUDE ALL CHARGES NOT COVERED UNDER PREVIOUS PERMITS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54423	16041-10001-14185	11881 W BRAY ST	90230	11	108B161   872	4218018043	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			Reviewed by Supervisor	06/04/2018 12:00:00 AM	ADDRESS	33.98938	-118.40769	PC ONLY FOR LOST SET OF PLANS. SCOPE INCLUDES 1 TESLA STORAGE  SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54424	18041-10000-27096	6000 W SANTA MONICA BLVD	90038	13	144B189   689	5534020***	(T)(Q)A1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.09049	-118.32049	FULL PC, TI ON A CHAPEL OCCUPANCY A > 100.  SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS. TOTAL SQ. FT. 2906.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54425	17041-10000-01071	10906 N LAUREL CANYON BLVD	91340	7	210B153  1096	2616011***	(Q)RD2-1-O-CUGU, RD2-1, T, Q	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.26863	-118.44228	PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON EXISTING 8 UNIT CONDOS(COMERCIAL). SYSTEM SIZE 4.96KVA TOTAL OF 16 MODULES(MODEL: CANADIAN SOLAR (CS6X-310P)), WITH SOLAREDGE POWER OPTIMIZERS(P400), AND 5KW CENTRAL INVERTER(SOLAREDGE SE5000A-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54426	16041-10000-31805	3221 1/2 N ANDRITA ST	90065	13	154-5A213  99	5458016023	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.11823	-118.24369	ROOF MOUNTED PVPV1 SFD TOTAL SYSTEM SIZE 3KW AC USING CENTRAL INVERTER SYSTEM AND 8 MODULES. PV SYSTEM IS CONNECTED TO METER ADDRESSED 3221 1/2 ANDRITA.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54427	16041-10000-10246	17383 W SUNSET BLVD A410-BLDG A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, PC FOR ENERYG ONLY. TI FOR AN EXISTING COMMERCIAL OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1090 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54428	17041-10000-40163	3950 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   636	5032007006	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.0149	-118.34226	Remove HID fixtures and replace with new LED fixtures  T-24 only7175 SQ.FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54429	19041-20000-07149	5536 N LINDLEY AVE 1-129	91316	5	174B125   454	2159005021	R3-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/08/2020 12:00:00 AM	ADDRESS	34.17161	-118.52708	PV2.  Install 100.38 kW DC / 91.72 kW AC roof mounted grid tied PV system.  (275) modules with (3) 30 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222 as amended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54430	16041-20000-40271	3100 W 3RD ST	90020	13	136-5A201 170	5501022026	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Expired	11/17/2022 12:00:00 AM	ADDRESS	34.06844	-118.28464	Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 30kW (6kW*5) ungrounded system. (105) 340W pv modules.$0 permit fee is due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54431	18041-10000-30594	9901 N MASON AVE	91311	12	201B109    84	2741004026	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.25039	-118.57998	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54432	16041-10003-09173	501 W EL SEGUNDO BLVD	90248	15	081B201   259	6132002024	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	33.91659	-118.28337	12/14/16PC ONLY FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED UNDER DELTA 5 ON PLANS. REVISED SINGLE LINE LAYOUT, REASSIGNING HOMERUNS, AND RELOCATING CIRCUITS BETWEEN PANELS.NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-09173	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54433	18041-10000-27903	12001 W VENTURA PL #210	91604	2	162B165    80	2368002001	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.14403	-118.39307	TI IN AN EXISTING OFFICE AREA IN SUITE #210.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54434	13041-10001-30920	2049 S THAYER AVE	90025	5	129B157   549	4317006022	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.05036	-118.42535	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54435	14041-20001-02843	13460 W POLK ST	91342	7	231B157   142	2582031054	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.32823	-118.4296	(((expedite fees)))pv1 single family dwelling. total system size 5kw ac using transformerless inverter nonstandard plan using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54436	10041-20000-03398	433 N HOOVER ST	90004	13	141A201   383	5539035005	R3-1	Central	Wilshire	East Hollywood	YES	1927.00	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM			PC Info Complete	08/30/2010 12:00:00 AM	ADDRESS	34.07874	-118.28455	Plan check power and energy for 2 story new office building.  Modification to seperate fire alarm plans has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54437	14041-10000-27747	5400 N BALBOA BLVD	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	PIN	34.16914714	-118.50029545	INTERACTIVE PHOTOVOLTAIC SYSTEM MOUNTED ON THE ROOF OF A COMMMERCIAL BLDGPERMIT FEE OF $0 IS DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54438	15041-10000-06006	1649 W SEPULVEDA BLVD	90501	15	045B193   440	7347017025	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	33.8169	-118.30807	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54439	13041-10000-04492	634 W 27TH ST 1-19	90007	9	121-5A203  72	5123015005	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			02/21/2013 12:00:00 AM			PC Approved	02/27/2013 12:00:00 AM	ADDRESS	34.02753	-118.27793	RENOVATION OF APARTMENT COMPLEZ. UPGRADE SERVICE TO 400A. PC FOR T24 ONLY. TOTAL AREA 204 ST FT FOR COMMON AREAS. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54440	17041-10000-33698	189 S THE GROVE DR EV	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM			Reviewed by Supervisor	09/27/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	PC FOR EV CHARGING STATION FOR THE GROVE. DWP TO PROVIDE NEW SERVICE OR EV CHARGING STATION ONLY FOR TESLA CHARGERS. INSTALLING 2000A SERVICE AND 12 SUPERCHARGERS THAT HAVE 2 CONNECTORS EACH. USING AUTOTRANSFORMERS FOR EACH SUPERCHARGER.B#17016-10000-27434	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54441	14041-20000-00510	10123 N WISH AVE	91325	12	204B133   386	2694004015	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.25482	-118.50795	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 9KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54442	12041-20000-14185	1910 S LA CIENEGA BLVD	90034	10	126B173   520	5066004018	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.04218	-118.37626	"Install indoor/outdoor general lighting.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date10/01/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54443	18041-10000-31024	333 S GRAND AVE 20TH FLR	90731	15	018B197  1671	7451019029	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	33.74081	-118.29031	20TH FLOOR TI OF 333 S GRAND AVE, LOS ANGELES CA INCLUDING ASSOCIATED ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54444	15041-20000-24629	500 S SANTA FE AVE	90013	14	126A217   245	5164004010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.04107	-118.23124	Plan check for Title 24 outdoor light under the bridge. Total outdoor light area: 71,653sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54445	13041-10000-12068	10031 N SYLVIA AVE	91324	12	204B117   511	2729026003	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.25283	-118.55291	PV SYSTEM 15.68 kw SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54446	14041-10001-18581	609 S LINCOLN BLVD	90291	11	111B145   817	4240016053	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM			PC Approved	08/12/2014 12:00:00 AM	ADDRESS	33.99989	-118.46525	(((8/6/2014  Suppl. application for change of lighting fixture b from recessed to surface mounted and increase in current limiter amperage for track lighting fixture c  (changes marked with delta 2 on plans))))PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR JUICE SERVED HERE. 1255 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54447	16041-10000-34913	3650 W MARTIN LUTHER KING, JR BLVD #224 & 226	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.01118	-118.33649	"Plan check for T-24 only. TI on existing ""Carter"" and ""Oshkosh"". Install new lights, receptacles, and panels. Total additional load is < 400A. Affected area: 8,144 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54448	15041-20000-35559	3001 E 11TH ST # 3	90023	14	120A223   136	5170024016	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.02096	-118.21424	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,150 sq. ft.Note: Building permit has been filed under 15016-20000-19169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54449	16041-10001-39068	6709 W SELMA AVE	90028	13	148-5A185 275	5547014039	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM			Reviewed by Supervisor	08/14/2019 12:00:00 AM	ADDRESS	34.09981	-118.3367	"DELTA ""3"" CHANGES TO APPROVED PLANS for changing 2 @ 1000 Amp CB's to Fused Disconnectes and changing the feeder lengths, adding an elevator, Etc. per as built plans.  AIC from LADWP is 95,400Amps. <<<Full PC for new 6 story apartment building (109 units) with subterranean parking garage and retail on ground floor. 21 typical units. New service rated 4000 Amps 208/120 3phase 4wire. Total sqft =103498  Building B.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54450	18041-10000-00799	10250 W SANTA MONICA BLVD # 1765	90067	5	132B161   512	4319003066		West Los Angeles				2679.01	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for first time tenant ""Blue Bottle Coffee"" ste. 1765 in Westfield Century City"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54451	17041-20000-05885	7992 N HOLLYWOOD WAY	91352	2	189B181   205	2403024007	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.21587	-118.34521	PV1.  Install 13.8 kW roof mounted grid tied PV system.  (40) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54452	12041-10000-27124	20305 W GRESHAM ST	91306	12	195B113   176	2781002001	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.23088	-118.57573	ROOF MOUNTED PV1 SOLAR INSTALLATION 3.07 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54453	11041-20001-08188	2029 S CENTURY PARK EAST 39th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			Corrections Issued	08/14/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to existing high rise building of entire 39th floor.  Plan check for power and energy.revision only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54454	18041-20000-25213	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022058	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.21384	-118.44905	New fire alarm system for three-story gymnasium and parking structure.  (142) devices with new FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54455	14041-20000-10997	13548 W PIERCE ST	91331	7	204B157   558	2646022006	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.25649	-118.42783	PV1. 3.9kw roof-mounted system with (1)Sunpower inverter tranformerless PVI -3.8-OUTD- US and (12)SPR-327NE modules interconnected with main panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54456	19041-10000-04532	5899 W VENICE BLVD	90019	10	126B173   737	5066016034	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.0403	-118.36952	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54457	11041-20000-18247	12504 W VANOWEN ST	91606	2	180B165    61	2325001005	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM	08/26/2011 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	PIN	34.19361778	-118.40563909	yogurt haven energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54458	13041-10000-16311	301 WORLD WAY	90045	11	090B161    33	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Closed	08/08/2018 12:00:00 AM	ADDRESS	33.94423	-118.40709	permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. PARKING  UPGRADES. LAX PS301 (elevator upgrades for priority II, III, and IV units)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54459	13041-10000-03868	620 S MORENO AVE	90049	11	126B137    35	4264006003	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.0446	-118.48544	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.86KW. USING CENTRAL INVERTER SOLAR EDGE SE6000A-US. 28 SOLAR PANELS TRINA SOLAR TSM-245PC05	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54460	17041-20000-32539	7283 W PACIFIC VIEW DR	90068	4	156A181   577	2428017004	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.12057	-118.35109	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters and (50) modules.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54461	17041-10004-09168	6904 S LA TIJERA BLVD	90045	11	102B173   202	4103010004	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	33.97579	-118.37323	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA CB5. INCREASE SIZE OF RTU'S AND REVISED TOTAL DEMAND READING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54462	18041-20000-36377	10545 N TUJUNGA CANYON BLVD	91042	7	207B197  1263	2557018015	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.26076	-118.29338	Plan check for a PV1 roof-mounted PV system. System size is 10.24 kWac and consists of (32) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54463	19041-20000-18553	13889 N ELDRIDGE AVE	91342	7	228B153   686	2503003018	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.32433	-118.43322	PLAN CHECK FOR NEW PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 5.025KW DC/4.271KW AC CEC/3.6KW AC. SCOPE OF WORK INCLUDES (15) LG SOLAR PV MODULES WITH ENPHASE IQ7 MICROINVERTERs.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54464	12041-20002-10803	4108 S DEL REY AVE	90292	11	108B153  1216	4230005040	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			01/21/2014 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.98836	-118.4448	(((CHANGES MADE TO APPROVED SET OF PLANS. SCOPE OF WORK IN STORAGE AREA IN THE LEASING TOWER. PLAN CHECK ONLY COVERS DELTA LT CHANGES)))New 77 unit apartment. Plan check for power and energy. 4 story apartment. Equipped with a generator. 106130 conditioned sqft. Fire alarm variance on file.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54465	11041-20000-13549	5838 W GREGORY AVE	90038	13	141B189    64	5534031007	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Apartment			06/29/2011 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.08609	-118.32353	PLAN CHECK POWER AND ENERGY NEW 7 UNITS 2 STORY APARTMENT WITH ONE LEVEL BASEMENT GARAGE. BUILDING IN METHANE BUFFER ZONE. NO METHANE MITIGATION REQUIRED ACCORDING TO METHANE REPORT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54466	17041-20000-42150	1925 S CENTURY PARK EAST 22nd floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT - REMODEL TO AN EXISTING OFFICE BUILDING ON PORTION OF THE 22ND FLOORBUILDING PERMIT # 17016-10000-30955	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54467	18041-20000-37188	17717 W LEMARSH ST	91325	12	204B129   234	2734001016	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.25604	-118.52046	Plan check for a PV1 roof-mounted PV system. System size is 16.8 kWdc/15 kWac and consists of (2) inverters, (48) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54468	15041-20000-38557	11682 N JACKMAN AVE	91342	7	213B149   111	2612017021	RS-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Expired	12/18/2017 12:00:00 AM	ADDRESS	34.28285	-118.45395	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(25) Kyocera KU265 Modules(1) ABB PVI-6000 Inverters(1) combiner box	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54469	19041-10001-08783	6600 N TOPANGA CANYON BLVD Suit 1080	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	11/20/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	"Replacing the Lost Plans. Plan Check Only.(((TI in an exiting retail ""Amazon"" store. Energy plan check only. Scope includes new lighting and equipment with a total area of 4,444-SQ FT.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54470	15041-30000-39704	11529 N COLLETT AVE	91344	12	213B141    99	2605020026	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.28015	-118.48444	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54471	15041-20004-39931	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Closed	03/08/2018 12:00:00 AM	ADDRESS	34.23911	-118.3725	Supplemental PC for changes to approved set. Adding receptacles and new panelboard LP1 and removing HVAC equipment. All changes clouded under delta 7.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54472	12041-20000-10046	10301 S AVALON BLVD	90003	8	091-5A207 318	6063013043	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	33.94271	-118.26543	TI for existing retail. O'Reilly Auto parts. 6290 condioned sqft. Single story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54473	17041-20000-32509	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.24138	-118.60168	New fire alarm system in 2-story commercial manufacturing building - new FACP and (133) notification/signaling line devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54474	19041-20000-18724	4224 S CLOVERDALE AVE	90008	10	114B177   157	5029041005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Expired	11/18/2023 12:00:00 AM	ADDRESS	34.01036	-118.36614	Plan check for PV with battery back up system, PV system size: 9.90KW with 33 PV Modules and 1 inverter(7.6kW), LG Chem, panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54475	14041-20000-35625	18165 W NAPA ST	91325	12	195B125  1030	2786002028	M1-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.22657	-118.52954	TI to existing  indstrial warehouse. Title 24 plan check only. 1340 Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54476	10041-20000-23884	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check for power new 600A board for electrical boiler equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54477	19041-10000-38998	17017 W LIVORNO DR	90272	11	126B121   315	4419017030	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.04279	-118.54959	[eplan] Roof-mounted  10.85 kW DC/8.99 AC pv1 system using 31 modules and microinverters(IQ7 plus)  with ess(tesla powewall) connected to existing 225a service	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54478	12041-10000-26495	20717 W STAGG ST	91306	3	189B109   935	2108036030	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.21128	-118.58471	4.57 kw roof mounted PV system for a single family. (PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54479	13041-20000-01318	7121 N CASE AVE	91605	2	183B173   128	2319022012	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.19995	-118.37345	T-24 and emergency lighting plan check for office remodel of existing vacant building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54480	14041-20001-13007	17544 W RAYMER ST	91325	12	192B129    70	2787024012	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.22619	-118.51743	EXPEDITE PER CUSTOMER REQUESTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.71KW INTERCONNECTED WITH MAIN PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54481	16041-10000-21595	12660 W RIVERSIDE DR STE 215	91607	4	168B161   467	2357033017	(Q)C1-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.15745	-118.40938	PC FOR ENERGY. TI - INTERIOR RENOVATION OF (E) MEDICAL OFFICE BUILDING.  NO CHANGE IN USE OR OCCUPANCY. TOTAL AREA 3418 SQ FT.B# 16016-10000-11086	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54482	11041-10000-24169	6301 W 3RD ST #J1	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			11/10/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	34.07243	-118.35963	T.I. for existing retail (Anthropologie) in first floor.  Install general/emergency lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54483	17041-10000-40183	412 1/2 W 95TH ST	90003	8	093A201   114	6039007024	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	33.94996	-118.28107	PC for 3.8kW rooftop solar voltaic system. Installing one central inverter, 10 PV modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54484	17041-20000-28100	14921 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29458	-118.456	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54485	10041-20000-09790	5727 N CANOGA AVE	91367	3	174B105    28	2146031200	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM	05/24/2010 12:00:00 AM		Permit Finaled	09/02/2010 12:00:00 AM	ADDRESS	34.17529	-118.5978	Adding some receptacles for trad mill and replaceing some lighting for gym of an appratment complex.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54486	18041-20001-02157	17647 W KITTRIDGE ST	91406	6	180B129   432	2229017014	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM			PC Approved	02/08/2018 12:00:00 AM	ADDRESS	34.19036	-118.51801	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (12) modules, (1) load center, and (1) Tesla PowerWall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54487	18041-10000-13480	612 S BROADWAY	90014	14	129A211   216	5144002019	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Info Complete	10/04/2018 12:00:00 AM	ADDRESS	34.0462	-118.25221	PLANCHECK FOR POWER AND ENERGY. CORE AND SHELL RETROFITTING BUILDING DUE TO SEISMIC RENOVATION . NEW SERVICE. HIGHRISE. SQFT 57,469.BUILDING PERMIT # 17016-10000-38600	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54488	14041-20000-05065	2000 N LAS PALMAS AVE	90068	4	150A185   143	5575011017	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.10631	-118.33622	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.78KW AC USING A COMBINATION OF MICROINVERTERS M215 AND CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54489	13041-10000-29863	735 S FIGUEROA ST # 203	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	"FIRST TIME TENANT FOR A ""MAC COSMETIC"" STORE. PLAN CHECK FOR POWER AND ENERGY. ADDING 2 NEW PANELS, 30KVA XFORMER. EXISTING 1200A, 480/277V 3PH 4W SERVICE. TOTAL ILLUMINATED AREA TO BE 1494 SQ FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54490	19041-20000-46753	10923 W WEYBURN AVE	90024	5	135B149   586	4363018034	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.06274	-118.44623	New fire alarm system for commercial renovation project.  (27) signaling line and notification devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54491	13041-10000-32169	12871 W RUNWAY ROAD UNIT 1-6-BLDG 3	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/26/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	33.97499	-118.41991	INSTALLATION OF A NEW FIRE ALARM SYSTEM for a 4 story residential building (Building 3). THIS IS BUILDING 3 OF 6.  THE FACP IS ON BUILDING # 2. There are two building types for the site. Building 3 plan is type 6 ( SIGNIFYING 6 PLEX ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54492	18041-20001-48175	555 S MATEO ST Bldg 2-1ST FLR	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.03943	-118.23302	08-28-2019 Changes to an approved set of plan, Supplemental plan check only, to recheck plans due to changes to power and lighting floor plans and T24. Single line and panel schedules are unchanged.Permit under this plan check covered under master application 18041-20000-48175	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54493	19041-10001-09131	8505 S WESTERN AVE	90047	8	097-5A193 263	6035032039	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM			PC Approved	05/03/2019 12:00:00 AM	ADDRESS	33.96069	-118.30921	"DELTA ""1"" CHANGES TO APPROVED PLANS.  TITLE 24 ENERGY ONLY FOR OUTDOOR LIGHTS IN A SCHOOL. TOTAL EFFECTED AREA 9389 SQFT. ""PLAN CHECK ONLY"".PERMIT #: 19041-10000-09131"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54494	11041-10001-27303	12123 W GREENOCK LANE	90049	11	135B141   476	4402018024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2012 12:00:00 AM			PC Approved	03/13/2012 12:00:00 AM	ADDRESS	34.06549	-118.47701	Revision to approved plans. Revise interconnection on the distribution panel, reduce one of two main overcurrent protection from 200A to 175A. Remove load center from installation.  Existing 400A panel. Sum of supplying overcurrent protection 200A+175A+25A=400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54495	19041-20000-51523	3730 N WOODCLIFF ROAD	91403	4	162A145   122	2279003010	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.13809	-118.46756	Plan check for Energy Storage System installed into existing PV System, Energy Stroage System size: 40.5KWh with 3 Energy Storage Devices(Tesla Power Wall 2.0).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54496	18041-10001-09709	931 W OXFORD AVE	90292	11	105B149   457	4229002013	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM			PC Approved	06/27/2018 12:00:00 AM	ADDRESS	33.98604	-118.44881	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES ADDING DISCONNECTS TO ESS PER DWP.THIS IS PLAN CHECK ONLY!  PC FOR TWO ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (125A) AND A NEW DISTRIBUTION PANEL (200A). PV IS EXISTING. TOTAL BATTERY SIZE INSTALLED : 10KWAC / 27KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54497	14041-20001-27288	17424 W CUMPSTON ST	91316	5	171B129    24	2257010055	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM			Reviewed by Supervisor	10/15/2014 12:00:00 AM	ADDRESS	34.1689	-118.51284	Expedite feePV1.  Install 5.50 kW roof-mounted, utility-interactive PV system.  AC Modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54498	19041-10000-08326	6160 N LAUREL CANYON BLVD #C	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	"NEW FIRE ALARM SYSTEM IN BUILDING ""C""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54499	19041-20000-08222	328 N KINGSLEY DR	90004	13	138B193   253	5521033014	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1925.20	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.07709	-118.30338	NEW 800A SERVICE, AND A NEW 800A MAIN DISTRIBUTION PANEL FOR FEEDING 7 DUPLEXES AND 2 TRIPLEXES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54500	19041-10000-26847	11779 W SHELDON ST	91352	6	198B169    30	2537023001	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	05/27/2020 12:00:00 AM		Permit Finaled	12/08/2023 12:00:00 AM	ADDRESS	34.24235	-118.38988	PC (POWER AND ENERGY) FOR 1-STORY  INDUSTRIAL BUILDING CORE AND SHELL. AREA OF SCOPE 6543SF. NEW SERVICE SIZE 800A, 120/240V, 3PH, 4WIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54501	15041-10000-31014	12457 W VALLEY VISTA WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.30841	-118.4059	PV1, roof mounted solar, 5.72 kWDC, adding new 125A subpanel for solar system to existing 200A panel, new utility lockable AC disconnect (22) modules: Hyundai solar HiS-S260RG(22) microinverters: Enphase M215-60-2LL-S22-IG	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54502	18041-10000-35841	4441 W SUNSET AVE F	90027	4	147A201   110	5542009028	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	PIN	34.09786301	-118.2859835	FULL PLAN CHECK FOR POWER AND ENERGY FOR - INTERIOR TI AT EXISTING SHELL FOR NEW GYM. - TOTAL CONNECTED APPROX. LOAD = 120A WITH AFFECTED AREA = 1321 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54503	19041-20000-21689	202 S MAIN ST	90291	11	111B141   444	4286003001	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Issued	08/07/2019 12:00:00 AM	ADDRESS	33.99763	-118.47899	TI to (E) commercial kitchen.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54504	17041-20001-28129	2440 S BARRINGTON AVE	90064	11	123B153  1166	4260032058	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	ADDRESS	34.03057	-118.44464	Expedite fee.PV2.  Install 20 kW roof mounted grid tied PV system.  (65) modules with (2) Fronius Primo 10 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54505	12041-10000-03320	1735 N LA BREA AVE 1-18	90046	4	147B181    80	5548001022	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Apartment			02/13/2012 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.10267	-118.34589	<<<Customer has a pre-cut check, additional fee for 220 New Cirucits (+$2,000) is required.>>>>>New 18 unit apartment building.  1200A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54506	11041-10000-10702	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM			PC Approved	05/25/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	ALTERATIONS IN DEL REY CLASSROOM PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54507	15041-10000-09942	8055 W 3RD ST UNIT A	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.07218	-118.36515	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2439	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54508	19041-10000-31800	949 E 2ND ST	90012	14	129A217   106	5163005018	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.04728	-118.23339	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54509	19041-10001-53498	7378 W PERIGORD CT	91042	7	210B197   517	2552048004	R1-1, RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM			PC Approved	01/22/2020 12:00:00 AM	ADDRESS	34.27163	-118.29428	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 60  (REC290TP2) MODULES, 60 (SE320) OPTIMIZERS, 2 SOLAREDGE INVERTERS (SE11400H-US & SE3800-H-US),  CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. DERATED MAIN BREAKER.  SYSTEM SIZE: 17.40KW DC, 15.20KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54510	14041-10000-22130	3033 W WILSHIRE BLVD	90010	10	135B197  1240	5077008018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.06198	-118.28733	New methane gas detection system for new 17 story apartment building.  Total # of devices = 52**SEE APPLICATION COMMENTS**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54511	17041-10000-39818	1609 W LOCKNESS PL	90501	15	045B193   408	7347017043	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.81827	-118.30584	Remove outdoor HID Fixtures and replace it with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54512	17041-10000-20800	110 W 11TH ST ste 300	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			No Progress	07/23/2018 12:00:00 AM	ADDRESS	34.0392	-118.25858	PC FOR T.I. FOR  OFFICE TITLE-24  ENERGY ONLY NEW LIGHTS, RECEPTACLES AND CIRCUITS. TOTAL AFFECTED AREA 4778 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54513	10041-10000-15180	11010 W PICO BLVD	90064	5	126B153  1103	4256007001	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	10/04/2010 12:00:00 AM	ADDRESS	34.03798	-118.43258	T.I. to existing building (Jack In The Box restuarant).  Install general/emergency lighting in dinning and restroom areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54514	16041-20000-36729	10611 W STALLION RANCH ROAD	91040	7	204B177   264	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.25746	-118.36078	pv1install roof mounted pv system sized 15kw interconnected with msp.$6.05 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54515	17041-10000-46493	230 S ALVARADO ST	90057	13	135A205   231	5154020031	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.06317	-118.27235	PC FOR COFFEE SHOP TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, CIRCUITS, LIGHATS AND EQUIPMENT. TOTAL AFFECTED AREA 1426 INDOOR AND XXXX OUTDOOR. B#17016-10000-38390	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54516	16041-20000-21319	2736 E BLANCHARD ST	90033	14	129A227    65	5177019023	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.04914	-118.19993	PV1.  Install 3.38 kW roof mounted PV system.  (13) modules with microinverters; microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54517	10041-20000-14534	4533 N LAUREL CANYON BLVD	91607	2	168B165  1003	2364005018	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Public Safety Only			07/27/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.15303	-118.39667	Plan check for installation of new fire alarm system for temporary portable trailers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54518	12041-20000-10278	1743 S WESTGATE AVE 1-3	90025	11	126B149  1082	4259014022	RD1.5-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	ADDRESS	34.03853	-118.45616	pv system for 1-family (? ) dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54519	17041-20001-38690	10948 N OSO AVE	91311	7	210B113   138	2707031008	(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.26913	-118.57623	01/19/2018 Changes to an approved set of plans. All changes have been clouded. There has been an addition of an AC disconnect for the Tesla PowerWall.*****Previous Work Description*****installation of (1) tesla power wall to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54520	16041-20000-11651	13933 W LEADWELL ST	91405	2	186B153   519	2216003012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.20398	-118.43679	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54521	14041-10000-25727	4706 W OAKWOOD AVE	90004	4	138B193   298	5522032012	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.07713	-118.30958	new 5-stories 27units apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54522	14041-10000-33586	933 S WESTWOOD BLVD	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.06311	-118.44559	Tenant improvement to (E) 3,234 sq. ft. commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54523	11041-20000-00745	612 S FLOWER ST	90017	9	129A209   264	5144005124	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	ADDRESS	34.0497	-118.25759	PLAN CHECK T24 ENERGY (GENERAL/ENERGENCY) LIGHTING FOR BAR/RESTAURANT LIGHTING REMODEL IN HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54524	19041-20000-22423	8862 W PICO BLVD	90035	5	132B169  1141	4305014***	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.05475	-118.38522	Plan check for PV roof mounted system, System size: 21.045KW with 61 PV  Modules and 2 inverters(9KW) connected to 2000A distribution system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54525	16041-30000-05362	1200 N CAHUENGA BLVD	90038	13	144B185   461	5533006032	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.09273	-118.32869	Title 24 plan check only.  Total area = 11,704 sq. ft. (conditioned) + 233 sq. ft. (unconditioned)     Renovation of private school with no change of use.  Existing distribution boards and subpanels to remain.  New or relocated loads totaling 378 Amps are on panels PA, PB, and PG only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54526	19041-10000-20979	6333 W 3RD ST #614	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.07157	-118.36014	T-24 PLAN CHECK FOR A TI OF A RETAIL STORE. NO CHANGE OF USE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 255 SQ.FT.B#18016-10000-41286	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54527	18041-10000-14845	734 E 3RD ST	90013	14	127-5A215  12	5163012004	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.04556	-118.23683	Addition to (E) single-story commercial retail building.  New 800A 240/120V 3ph-4w service, house lighting and power, and new distribution.Building permit under 18014-10000-00332.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54528	19041-20000-14238	10436 W TROON AVE	90064	5	126B161   412	4318018043	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.03916	-118.41204	PLAN CHECK FOR INSTALLATION OF NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 5.4 KW DC/4.725KW AC. SCOPE OF WORK INCLUDES (15) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND (2) 100A SOLAR LOAD CENTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54529	18041-20000-10461	21300 W VICTORY BLVD 7th Floor	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Issued	03/22/2018 12:00:00 AM	ADDRESS	34.18813	-118.59618	Existing corridor remodel in commercial highrise building.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54530	13041-10001-22256	23724 W MIRANDA ST	91367	3	174B093   180	2045024038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.17444	-118.64391	"""Expedited plan check per applicant request"".PV1 10.78KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-3.6-OUTD-US ] [( 44) MOD: TRINA {TSM-245PC05.18}]"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54531	12041-10000-19990	546 N OXFORD AVE 1-25	90004	13	141B193  1005	5521013004	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			08/23/2012 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.08121	-118.30785	PLAN CHECK POWER ANS ENERGY FOR NEW 25-UNIT APARTMENT BLDG; 2-STORY BLDG. WITH BASEMENT PARKING GARAGE. 1200A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54532	19041-10000-11102	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/03/2020 12:00:00 AM	ADDRESS	34.16326	-118.37388	Full PC, first time TI for a portion of a building under owner build out with new ligthing and equipment, the other portion is under plan check, currently under Medhi with application number: 18041-10000-32309.  Note. Client to request Medhi as plan checker due to two plans supplied by one distrubition panel. BUILDING PERMIT: 18016-10000-27289	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54533	19041-10000-09588	1403 N GARDNER ST	90046	4	147B177  1248	5550025902	[Q]PF-1XL	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.09638	-118.353	Plan check for power only in a hazardous area Class I Div. 2. Install (2) 50HP  Fan Motor in a Carbon Scrubber Facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54534	16041-10001-19558	22258 W JAMES ALAN CIR 1-8	91311	12	207B101   244	2723013***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.25979	-118.61169	07/14/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REVISING THE SOLAR ROOF-LAYOUT FOR THE PV MODULES.NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-19558((((PV1 6.54kw STANDARD ROOF-MOUNTED SYSTEM WITH (20) AC modules interconnecting through the load center and main service panel. Sun Power solar monitor is being installed on the load center. Note: Standard Plan, plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54535	15041-10000-15226	2870 W ROWENA AVE	90039	4	151-5A207 162	5434033034	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.10775	-118.26679	T24 ONLY. TI FOR A RESTURANT. TOTAL AREA 925 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54536	12041-10000-15507	253 N WESTERN AVE 2nd floor	90004	4	138B193   488	5517004018	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10, 2115.00	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.07609	-118.30932	"Change to lighting and circuits to an existing office space on the 2nd floor.  Load is 122 Amps, per applicant.  Plan check only for Energy, with Emergency lighting.  Permit fees are under ""INSPECTION""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54537	19041-10000-35135	17540 S DENVER AVE	90248	15	063B201    83	7339007013	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	33.87108	-118.28304	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54538	15041-20001-16317	936 S OLIVE ST UNIT 249	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #16 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54539	15041-20000-25059	7359 N AMESTOY AVE	91406	6	186B133   776	2227011016	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.20454	-118.50607	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel.(16) Sunpower E320 Modules(1) ABB PVI 5000z	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54540	15041-10000-34687	717 N ARAGON AVE	90065	1	145-5A219 333	5453027005	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	08/27/2016 12:00:00 AM	ADDRESS	34.09169	-118.22154	PV1.  Installation of 2.12 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54541	17041-10000-32551	3455 E PERCY ST	90023	14	121-5A227  53	5188004053	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.0282	-118.19859	Remove HID fixtures and replace with new LED fixture  - Title 24 only. Total affected area 18075sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54542	17041-10000-04431	2015 S SANTA FE AVE	90021	14	118-5A217  20	5167012036	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.02066	-118.2304	PC for indoor title 24. Removing HID fixtures and replacing them with new LED fixtures. Area: 4,100 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54543	10041-10001-09529	10250 W SANTA MONICA BLVD 206	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Changes to approved Plans. Install a 30KVA step down transformer 480:280V, 3 Phase for the 24KW, AC unit on the roof.    CHANGE OF USE FROM RETAIL TO RESTAURANT. 1968 sq. ft.  EPC for power  and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54544	13041-10000-14563	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. NO EMERGENCY LIGHTING IS INCLUDED IN SCOPE OF WORK. PROJECT IS IN A HIGH RISE. REMINDER: TITLE 24 PERMITS SHALL BE OBTAINED THROUGHT THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54545	11041-10001-24005	929 N CYPRESS AVE	90065	1	145-5A219 184	5453022900	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Info Complete	05/10/2013 12:00:00 AM	ADDRESS	34.09307	-118.22495	Title 24 energy and emergency lighting.  plan check previously approved but expired.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54546	15041-20000-35234	20043 W ARMINTA ST	91306	3	189B113   836	2106022046	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.21328	-118.57005	PV1, roof mounted solar system 9.01 kW.(34) modules: #KU2656ZPA(1) inverter: PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54547	15041-20000-29145	300 S GRAND AVE 17th Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	Title 24 plan check only.  Total area = 1,773 sq. ft.  New lighting in corridor of existing commercial highrise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54548	14041-10001-06723	735 S AVENUE 61	90042	14	150A233   119	5312024079	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.10542	-118.17943	EXPEDITED RSES PLAN CHECK  PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  2-STORY HOME. INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12)MODULES: TRINA SOLAR TSM-250PA05.18THIS PLAN HAS ALREADY AN EXPRESS PERMIT AND THIS APPLICTION IS PROVISION REGARDING FIRST PERMIT# 13041-20000-32619.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54549	11041-10002-09464	8500 W BEVERLY BLVD #820	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	REVISIONS TO APPROVED SET OF PLANS- ADDED 2 EA SEF UNITS AND SHOW ON THE PLANS THE WORK TO BE DONE IN EACH PHASE OF WORK)))))))TENANT IMPROVEMENT TO (E) RETAIL SPACE (#820):	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54550	19041-10000-00600	10351 W ARNWOOD ROAD	91342	7	210B177    49	2529004008	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.27585	-118.35462	NEW ROOF MOUNTED 16.43 KW (DC) PV SYSTEM WITH 53 PV MODULES AND 2 INVERTERS ON A SINGLE FAMILY HOME. $0 PERMIT FEE PER ASSEMBLY BILL AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54551	15041-20000-13268	13920 W VAN NUYS BLVD 101-106	91331	6	204B153   484	2645001025	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.25584	-118.43585	Plan check for power and energy to Building Addition to existing space. New service and equipment rated for 800A with mutiple tenants. Total area: 19,951 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54552	17041-20000-23707	3274 S VETERAN AVE	90034	5	120B157   501	4254020020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.02511	-118.42006	Plan check for roof-mounted solar pv system w/AC coupled battery backup system (on SFD).System size: 6.16kW ungrounded.(22) EnPhase IQ6PLUS microinverters.(22) 320W pv modules.(1) 5kW Tesla Powerwall 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54553	15041-10000-42056	1435 S CARMONA AVE	90019	10	129B177  1071	5069024007	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.04809	-118.35842	PV1, INSTALL 6.89 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (246 MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB-PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54554	11041-10001-10386	1114 S GAYLEY AVE	90024	5	132B149   105	4363023027	C4-2D-O	West Los Angeles	Westwood			2652.02	Electrical	Electrical	Commercial			10/13/2011 12:00:00 AM			PC Approved	10/13/2011 12:00:00 AM	ADDRESS	34.05987	-118.44596	REVISED PERMITTED SET OF PLANS-LIGHTING PLANS CHANGED RESULTING IN LESS LUMINAIRES AND LIGHTING WATTAGE INSTALLED. NO CHANGES IN THE POWER PLANS((((((((((CHANGE OF USE FROM EXISITING  PORTION OF RETAIL TO   RESTUARANT, T.I ON EXISITIN PORTION ( 15' X 78 ') OF RESTAURANT ;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54555	16041-10000-29603	8400 N BALBOA BLVD	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.22376	-118.50243	Full PC for new fitness center construction with new 1200 A service and 39065 sqft.**PROPOSED (1) STORY 37,000 SF FITNESS CENTER; PROJECT WILL CONSIST OF AREAS FOR WEIGHT TRAINING, CARDIO, CIRCUIT TRAINING, BASKETBALL COURT, AEROBICS, CYCLING, LAP POOL, RESTROOMS, LOCKER ROOMS, KID'S KLUB AND PERSONELLL TRAINING AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54556	16041-10000-21992	34 W ST JAMES PARK BLDG B	90007	1	123A201   135	5124024011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Apartment			06/22/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.03121	-118.28053	Install New F.A system on (E) Senior Residence Apt.  (3) panels    (42) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54557	13041-10000-35310	4330 W BURNS AVE 1-67	90029	13	144B197  1285	5539011027	RD1.5-1XL	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Apartment			12/18/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.08756	-118.28819	FIREALARM PANEL REPLACEMENT ONLY.  REPLACING EXISTING FIRELITE MS-124 PANEL WITH FIRELITE MS-4 PANEL. ALL DEVICES EXISTING TO REMAIN. WORK IS ONLY ON EAST BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54558	13041-10000-10394	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			PC Approved	04/23/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	TI of medical office patient waiting room and reception.  Partition separating reception and waiting area demoed and replaced with a counter.  Lighting and receptacles installed.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54559	13041-20000-11377	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Info Complete	06/13/2013 12:00:00 AM	ADDRESS	33.78734	-118.29768	FULL PLAN CHECK FOR EXISTING MEDICAL OFFICE. 1887 SQRFT. PER APPLICANT NOT OSHPOD3 BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54560	11041-10000-21426	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	New Fire Alarm installation with 70 devices and one fire control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54561	16041-10000-01209	9185 N DE SOTO AVE	91311	12	198B109   127	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Expired	02/20/2018 12:00:00 AM	ADDRESS	34.23801	-118.5888	PC FOR ENERGY RENOVATION FOR A MCDONALD BUILDING STORE. CHANGE FIXTURES TO LED LLIGHT FIXTURES.  TOTAL AREA 1525 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54562	13041-10000-26100	380 WORLD WAY #T-59	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	installation of led sel-illuminated signs on the external walls of a the tenant space CNN Newstand Los Angeles on the 4th fl of the TBIT; A TIME CLOCK CERTIFIED BY THE California Energy Commission will be controlling the frontal signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54563	15041-10000-42427	101 N ROBERTSON BLVD	90048	5	138B169   353	4334001012	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.07543	-118.3839	T-24, TI TO AN (E) COMMERCIAL BUILDING, SCOPE OF WORK INCLUDES NEW LIGHTING TO INDOOR AND OUTDOOR SPACES. TOTAL SQ. FT. 3968.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54564	17041-20000-06930	5700 W WILSHIRE BLVD Floors-2,3,4,6	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.06218	-118.35303	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is elevator lobby remodels to floors 2, 3, 4, and 6. Total lighting area = 1,387 sq. ft.Note: Building permit has been pulled under 16016-10000-30618	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54565	14041-20000-30755	15746 W ADDISON ST	91436	5	171B141   475	2261004003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2014 12:00:00 AM			PC Approved	11/19/2014 12:00:00 AM	ADDRESS	34.16155	-118.47645	CHANGE TO APPROVED SET. ORIGINAL PLAN 14041-20000-27991. CHANGE LOCATION OF INVETER TO OTHER SIDE OF DWELLING UNIT. AC CONDUCTORS RETURN BACK TO SERVICE VIA ROOF.THIS IS PLAN CHECK FOR CHNAGES DELTA 2. REFER TO THIS NEW SET OF PLANS FOR COMPLETE INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54566	19041-10001-06925	1243 W DENNI ST	90744	15	033B201   613	7415020029	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	33.78423	-118.2795	(VOID app)pc for pv system. system includes (21) modules (REC solarr: RETP2), (21) 320 solar edge optimizers, (1) LG chem 5kw battery, (1) solar edge 7600 inverter. (1) load panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54567	16041-10000-27063	5681 W JEFFERSON BLVD	90016	10	120B173   249	5048016026	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	11/07/2017 12:00:00 AM		Issued	11/07/2017 12:00:00 AM	ADDRESS	34.02671	-118.3714	PC FOR POWER. CONSOLIDATING SERVICES INTO ONE 1600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54568	15041-20000-15459	11251 W SUNSHINE TER	91604	2	162B173   589	2378010029	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.13981	-118.37474	Plan check for PV roof monted 6.0kW system 24 modules and microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54569	18041-20000-09643	1437 S ROBERTSON BLVD	90035	5	129B169    65	4305014029	C2-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.05365	-118.38412	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 1,502 sq. ft.Note: Building application has been generated under 17016-20000-01916	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54570	15041-10000-10591	968 S BERENDO ST	90006	10	129B197    41	5078008034	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.05365	-118.29357	NEW FIRE ALARM SYSTEM WITH 302 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54571	18041-10000-12535	2566 W SAN FERNANDO ROAD	90065	1	150B213   435	5457002013	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Info Complete	12/12/2018 12:00:00 AM	ADDRESS	34.10836	-118.24175	SERVICEE UPGRADE FROM 200A TO 600A.NO NEW LOADS ARE ADDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54572	17041-10000-30511	845 S BURLINGTON AVE	90057	1	130-5A203 125	5142005021	R3-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.0523	-118.27533	Plan check for Title 24 only in existing space.  replace existing fixtures with LED fixtures. Total area: 8550 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54573	19041-10001-39436	8656 N SEPULVEDA BLVD	91343	6	195B145   525	2654021132	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	34.22784	-118.46743	DELTA C CHANGES TO APPROVED SET. CHANGES TO DINING AREA LIGHTING LAYOUT AND ADDITION OF COVE LIGHTS. ADDITIONAL PERMIT FEES ARE ADDED TO THE MASTER PERMIT. ****ENERGY PC FOR INTERIOR AND EXTERIOR TENANT IMPROVEMENT OF EXISTING DRIVE-THRU RESTAURANT. AREA OF SCOPE 2924SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54574	17041-20000-46554	100 WORLD WAY Space 140	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	Plan check for power and energy. TI to LAX airport terminal kiosk SPACE 140 - coffee/cafe (Urth Cafe). New lighting (incl. emergency) and elec. eqiupment - 2,055sqft.Note: Building application has been generated under 18016-10000-00413	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54575	13041-10000-32971	201 N FIGUEROA ST	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Public Safety Only			11/25/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Issued	03/04/2014 12:00:00 AM	ADDRESS	34.05859	-118.25142	Fire warning system replacement	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54576	12041-20000-13118	1300 W 24TH ST	90007	8	123B197   573	5055003026	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	ADDRESS	34.03423	-118.28913	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54577	15041-20000-27030	930 N ONEONTA DR	90065	1	153A221   228	5475015026	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.11362	-118.21572	Plan check for PV roof mounted system. System size: 6.12kW with 24 modules. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54578	15041-20000-31821	13539 W TERRA BELLA ST	91331	7	204B157  1216	2646015033	R1-1	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.25152	-118.42793	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.  Central inverter system	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54579	11041-10001-03497	250 E MANCHESTER AVE	90003	9	097-5A205 350	6041016003	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM			PC Approved	03/16/2011 12:00:00 AM	ADDRESS	33.95987	-118.27031	CHANGE THE APPROVED PLAN. CHANGE THE LIGHTING AND SWITCHES. EPC IS FOR T24. ((((((((((((T.I.  EXISTING OFFICE SPACE.  ELECTRICAL PLAN CHECK FOR TITLE 24)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54580	15041-10000-41225	810 E PICO BLVD # 316	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.03119	-118.25079	ALTERATIONS IN EXISTING OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54581	19041-10000-19785	7670 N HOLLYWOOD WAY	91505	2	189B181   651	2405017002	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1021.05	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.21063	-118.34833	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54582	17041-10000-00565	719 E 25TH ST APT D	90011	9	120A209   250	5131023022	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Apartment			01/06/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.02228	-118.26008	PV2, INSTALL NEW 3.8 KW AC ROOF-MOUNTED SOLAR SYTEM FOR AN EXISTING MULT-FAMILY HOUSE .(12)MODULES: AXITEC AXLPOWER AC-265P/156-60(1) INVERTER:FRONIUS PRIMO 3.8-1	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54583	12041-20000-24539	1815 W FAIR PARK AVE	90041	14	160-5A225 248	5689001011	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.13454	-118.20689	New M215 Enphase Microinveter photovoltaic system.  4.8kwDC, rooftop mounted on an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54584	17041-10000-35969	5343 W IMPERIAL HWY 800-850	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	33.93128	-118.37337	PC FOR WAREHOUSE TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES REPLACING LIGHTS. TOTAL AFFECTED AREA 17,827 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54585	12041-10000-30627	8156 W MELROSE AVE	90048	5	141B173   461	5528011004	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	PIN	34.08346465	-118.36725718	TENANT IMPROVEMENT  AT AN IMPROV/RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54586	10041-10000-19016	9301 N TAMPA AVE # 29A	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM			PC Approved	09/24/2010 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVEMENT  472 SQ FT  TO EXISTING RETAIL SPACE; PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54587	12041-20000-20630	3724 N LITCHFIELD LANE	91356	3	162B117   392	2177043010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.1367	-118.55187	New 16.2kw rooftop photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54588	13041-20000-19104	5890 W HOLLYWOOD BLVD	90028	13	148-5A191 180	5545004004	[Q]C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.10151	-118.31777	T24 FOR EXISTING GAS STATION CONVENIENCE STORE. SCOPE OF WORK ONLY IN CONVENIENCE STORE AND REPAIR GARAGE. 2305 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54589	13041-20002-35198	3415 N GREEN VISTA DR	91436	5	159B133   182	2287010070	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.13243	-118.49905	"(((CHANGES MADE TO APPROVED SET OF PLANS. INVERTER AND SUBPANEL RELOCATION. SINGLE LINE HAS NOT BEEN CHANGED OTHER THAN THE FEEDER LENGTH)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.  "" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54590	18041-20000-29305	12033 N LONGACRE AVE	91344	12	216B125   408	2601031039	(Q)RE40-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM			PC Approved	08/28/2018 12:00:00 AM	ADDRESS	34.2896	-118.53069	Plan check for PV roof mounted system, sysem size: 22.8kW with 69 pv modules and 2 inverters(11.4kW) connected to 400A panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54591	14041-20000-28001	2541 S DUNSMUIR AVE	90016	10	123B177   832	5043002004	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Expired	11/02/2016 12:00:00 AM	ADDRESS	34.0331	-118.35955	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(16) SOLAR WORLD 270W MODULES(1) POWER ONE 3.8KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54592	19041-10000-40202	20720 W COMO LANE	91326	12	213B109   183	2701053002	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.27834	-118.58417	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 6KVA PV1 SYSTEM CONSISTING OF 25 MODULES(HANWHA Q CELLS G3 315) USING MICROINVERTERS(ENPHASE IQ7-60-2-US) CONNECTED TO EXISTING 200A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54593	13041-20000-27920	5700 W WILSHIRE BLVD #350	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			Ready to Issue	10/08/2013 12:00:00 AM	ADDRESS	34.06218	-118.35303	Relocate 6 lights only in an existing high-rise office building.  All loads are existing per the applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54594	14041-10000-15117	619 S HAUSER BLVD	90036	4	135B181   676	5508014010	[Q]R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			06/06/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.06428	-118.35157	plan check for power only. Changes on plan include notes and parallel conductors for service. SERVICE UPGRADE FOR EXISTING APARTMENT BUILDING. 120/240 1P3W 600A SERVICE. REPLACING ALL SUBPANELS AS WELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54595	13041-20001-34049	7250 N HAZELTINE AVE	91405	2	186B153   714	2216002058	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Apartment			12/06/2013 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.20287	-118.43981	((Expedite fees))PV2 MICROINVERTER SYSTEM FOR APARTMENT. TOATL SYSTEM SIZE 30KWAC. 120 MODULES AND MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54596	16041-10000-40889	1035 S CRESCENT HEIGHTS BLVD 1-2	90035	5	132B173   562	5087013022	R2-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Expired	09/08/2023 12:00:00 AM	ADDRESS	34.05783	-118.36993	PV ISTALL NEW 7.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON A DWELLING HOUSE.(22) MODULES: SPR-X21-345W(1) INVERTER: SB7000TL-US-22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54597	18041-20001-35459	314 S GLENROY AVE	90049	5	135B145    63	4366020008	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			PC Approved	09/22/2018 12:00:00 AM	ADDRESS	34.06999	-118.46033	Expedite per applicant requestPlan check for PV roof mounted system, system size: 12.87kW DC 39 PV modules and 1 inverter(11.4kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54598	15041-20000-31377	19520 W NORDHOFF ST UNIT 6	91324	12	195B117    12	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.23378	-118.55808	NEW OFFICE TI. ALL NEW OFFICE SPACE IN UNIT 6. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54599	17041-10000-29596	10700 N PELUSO AVE	91040	7	207B185   295	2548009021	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.26395	-118.33529	PC FOR PV SYSTEM. 6KWAC USING 21 MODULES. SYSTEM USES POWER OPTIMIZERS AND CENTRAL INVERTER. USING LADBS STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54600	17041-10000-25533	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC for T24 for outdoor ornamental lighting to a highrise building facade. Load under 400 A. Total sqft 102400 sqft. Building# 17016-10000-20778.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54601	16041-10000-44335	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC for title 24 to existing conference room on first floor.  New 112.5 kVA transformer feeding a 400 amp distribution board with one subpanel.  Adding new lighting and power.  Totals sqft: 4,426.**SEE APPLICATION COMMENTS**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54602	17041-30000-33494	2029 S CENTURY PARK EAST 12th Floor-RR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing highrise men and women restroom 12th Floor. Total area: 410 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54603	12041-20000-31003	9541 N OAKRIDGE PL	91311	12	201B097   153	2724011006	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.24393	-118.62088	Enphase photovoltaic system on roof of single family dwelling with PV subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54604	14041-20000-06003	10030 W RUTLEDGE PL	91352	2	189B181   262	2403012018	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.21479	-118.3493	PV1 ROOFMOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54605	13041-10000-30812	2227 S MALCOLM AVE	90064	5	126B157   301	4320001044	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.04413	-118.42939	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 18 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54606	15041-10000-20833	2522 W 75TH ST	90043	8	102B189  1900	4009015011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	33.97175	-118.32179	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.2KW INTERCONNECTED WITH MSP.(36) SUNPOWER MODULES(2) POWER-ONE INVERTERS 4.2/6000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54607	15041-20000-14866	16826 S ORCHARD AVE	90247	15	066B197   124	6121009050	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	33.87837	-118.28746	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (28) power optimizers. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54608	14041-10000-06042	800 W 6TH ST 2ND FL	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.05011	-118.2577	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54609	19041-10000-23132	6126 W BARROWS DR	90048	5	132B177   302	5088004041	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.06009	-118.36384	(ePlan)  Install 2 Energy Storage Systems @ @27KWH total, 2 New 125A Load Centers, 1 New 200A Load Center.*Note: 200A New Main Service panel shall be under separate express permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54610	19041-10000-02777	5877 W FRANKLIN AVE	90028	4	150A191   167	5586023039	C2-1, P-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.10542	-118.31769	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54611	18041-20000-07995	2201 S DUXBURY CIR	90034	5	126B165   226	4309009035	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM			PC Approved	05/03/2018 12:00:00 AM	ADDRESS	34.04357	-118.39644	New SFD with a 600A 240/120V service.  Plan check for power only.  Electrical permit fees paid under builing combination permit.  Building permit under 16010-20000-05426.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54612	14041-10000-19542	1603 W WILSHIRE BLVD	90017	1	132A205   392	5142009035	C2-2, C4-2, R4P-2, R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.05565	-118.27031	CHANGE OF USE FROM RETAIL TO RESTAURANT (2,176 SF). NEW NON-BEARING PARTITIONS, T-BAR CEILIBG, WALK-IN COOLER, NEW TYPE I HOOD WITH NEW EXHAUST FANS AND MUA UNIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54613	13041-20000-35473	14823 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			Reviewed by Supervisor	02/12/2014 12:00:00 AM	ADDRESS	34.17768	-118.45525	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING SPACE THAT HAS BEEN GUTTED. NEW LOAD EXCEEDS 400A AND NEW SERVICE DROP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54614	17041-10001-28243	403 N CENTRE ST	90731	15	018B201   356	7449009015	R2-1XL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	33.74618	-118.28363	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54615	10041-10000-10553	3566 W 3RD ST	90020	4	135B197   176	5502007001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.20	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.0689	-118.29359	New Coin Laundry. (Previously it was Medical Office)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54616	13041-20000-01597	445 S FIGUEROA ST 30th Floor-31st Floor	90071	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.00, 2077.10	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for energy and emergency lighting. 30th and 31st floors. 846sqft total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54617	19041-20000-09596	516 N LA BREA AVE	90036	5	141B181  1083	5525020008	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.08081	-118.34385	T24 PLAN CHECK FOR EXISTING COMMERCIAL RETAIL BUILDING. TOTAL AREA = 2480 SF INSTALLING LIGHTS, OUTLETS, AND EQUIPMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54618	18041-20000-18704	1670 W BEVERLY BLVD 2nd Floor	90026	13	135A207   236	5153012023	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.06416	-118.26523	First-time tenant to 2nd-floor commercial office space.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54619	18041-20001-36716	7037 N RESEDA BLVD	91335	3	183B125   454	2126008009	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.19878	-118.53624	11/30/2018changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.((((pv2install roof mounted pv system sized 7.7KW AC interconnected with msp.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54620	12041-20000-03152	1100 S GLENDON AVE #1600	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Expired	03/06/2014 12:00:00 AM	ADDRESS	34.06074	-118.44418	energy plan check # 1600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54621	13041-20000-17994	418 S SPRING ST	90013	14	129A211   276	5149038***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	10/24/2013 12:00:00 AM		Permit Expired	11/18/2015 12:00:00 AM	ADDRESS	34.04834	-118.2485	PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT IN EXISTING HISTORIC BUILDING. TOTAL SQRFT 9053.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54622	19041-20000-37554	21800 W OXNARD ST Ste. 1140	91367	3	177B105    81	2146006046	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for Title 24 energy only in existing office space Tenant Imporvement. Total area: 2884 sq ft. B#19016-40000-20147	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54623	16041-10000-11579	6701 S CENTER DR WEST 3RD FLR	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM			PC Approved	05/23/2016 12:00:00 AM	ADDRESS	33.97907	-118.39369	Full PC. Tenant improvement to 3rd floor of a highrise building (office space). New lighting and power. Newly connected load is greater than 400 amps. Total sqft = 22,185.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54624	18041-10000-42045	551 S LORENA ST	90063	14	123A227   236	5186008033	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.20	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Issued	11/02/2018 12:00:00 AM	ADDRESS	34.03117	-118.19904	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54625	19041-20001-36596	22110 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	09/16/2020 12:00:00 AM	ADDRESS	34.1863	-118.60874	Expedite per applicant request. Plan check for PV roof mounted system, system size: 19.14KW DC, 16.9KW AC CEC with 44 PV Modules and 2 inverters(9KW)Applicant request: plan stay %%%%%%%%%%%%%   Van Nuys     %%%%%%%%%%Note: 12 Buildings in 1 plan set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54626	18041-10000-48443	4400 S BROADWAY	90037	9	112-5A203  68	5110002026	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2319.00	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.00363	-118.27812	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54627	18041-20001-25009	19010 W KESWICK ST	91335	3	186B121    45	2104013009	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM			PC Approved	09/27/2018 12:00:00 AM	ADDRESS	34.21003	-118.54741	09/27/2018 Changes to an approved set of plans. PV system interconnection configuration has been revised.*****Previous Work Description*****Plan check for PV roof mounted system, system size: 10.79kW AC CEC with 47 modules and 2 inverters(5.2kW and 7.6kW) connected to MSP 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54628	17041-10001-18929	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Issued	07/07/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	Plan check only for fire alarm in pre-fabricated building under master permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54629	16041-10001-07377	777 S SANTA FE AVE CMU	90021	14	124-5A217 270	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.03354	-118.23024	09/29/16Changes to an approved set of plans. All changes are clouded under delta 5. Changes include removing 1 duct smoke detectors, and revising battery calculations. Note: Permit is paid under PCIS#16041-10000-07377(((((Installation of new fire alarm system in Ford Factory.  This is for CMU	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54630	10041-10000-02488	3560 S WATT WAY #130	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	03/22/2010 12:00:00 AM		Permit Finaled	06/09/2010 12:00:00 AM	ADDRESS	34.02169	-118.28671	Plan check T-24 Energy for general/emergency lighting USC Ped #130 office renovation. Permit is for work on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54631	19041-10000-21077	20800 W LASSEN ST	91311	12	201B109   117	2748004058	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			Reviewed by Supervisor	06/27/2019 12:00:00 AM	ADDRESS	34.24984	-118.58655	(Assign to Edwin or John per Mr. Nabil request) Power plan check for a medium voltage equipment system  with a scope of 5KV 600Amp service including (1) 500KVA step transformer and (1) 600-Amp 480/277V distribution panel. Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application # 19041-10000-19576	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54632	13041-10000-27191	4550 W PICO BLVD #D-303	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.04842	-118.33486	PLAN CHECK POWER AND ENERGY FOR SMART & FINAL STORE (SUITE D-303)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54633	13041-10000-33355	520 S VIRGIL AVE # 506 &-# 507	90020	13	141A201   239	5539029041	CR-1, R3-1	Central	Wilshire	East Hollywood, Rampart Village		1927.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.06457	-118.28687	pc for power and energy. T.I. DOCTOR'S OFFICE.  (2,863 S.F.)  NON-BEARING WALLS, NEW INTERIOR FINISHES. 13016-10-23518.  Expedite & energy fee on Submittal 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54634	14041-20001-01872	1768 S HAYWORTH AVE	90035	10	126B173   264	5066018017	R1-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/02/2014 12:00:00 AM	ADDRESS	34.0439	-118.36982	(((EXPEDITE FEES)) pv1 single family dwelling. total system size 5kw ac using 20 modules. transformerless inverter with power optmizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54635	12041-20000-17072	12103 W VENTURA BLVD	91604	2	162B165  1112	2367016013	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM			PC Approved	07/23/2012 12:00:00 AM	ADDRESS	34.14369	-118.39571	T24 energy plan check for remodel of pizza restaurant.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54636	18041-20000-09275	1926 E 7TH ST	90021	14	124-5A217 252	5166016005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.03446	-118.23293	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from warehouse to office/tenant improvement. Total lighting area = 1,035 sq. ft.Note: Building application has been generated under 17016-10000-36627	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54637	15041-20000-03469	10960 W WILSHIRE BLVD SUITE 1050-1060	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.058	-118.44597	PC FOR T24 ENERGY ONLY. NEW LIGHITNG TO EXISTING HIGH RISE OFFICE SPACE. WORK DONE IN SUITE 1050-1060	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54638	14041-10001-27207	5215 N EAGLE DALE AVE	90041	14	163-5A217  45	5680028008	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	34.14332	-118.22836	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 2.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(8) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54639	11041-10000-08611	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02, 2780.00	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	04/28/2011 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	33.95667	-118.4165	REPLACEMENT OF EXISTING NON-FUNCTIONING FIRE ALARM PANEL WITH NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54640	15041-20001-21982	6600 N TOPANGA CANYON BLVD Suite 1086	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	08/13/15 Changest to an approved set of plans. Delta 3 changes. Adding a current limiter for track lighting. Relocating transformer. Adding a circuit for sanitary lift pump.(((Title 24 plan check only.  Total area = 1,825 sq. ft.  T.I. to existing retail tenant space.  New lighting and recepticles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54641	18041-30000-42983	2049 S CENTURY PARK EAST ROL #16	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR RESTAURANT TI FOR NEW STARBUCKS FOR T-24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1405 SQ.FT.  B# 18016-10000-35890	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54642	12041-10000-06743	6957 N FIGUEROA ST	90042	14	159A229   340	5480009019	R1-1, RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Expired	07/01/2014 12:00:00 AM	ADDRESS	34.12876	-118.18798	NEW ROOF MOUNTED 57KW PHOTOVOLYAIC SYSTEM FOR PRIVATE SCHOOL. PV MODULES INSTALLED ON THREE SEPERATE BUILDINGS TO ONE CENTRAL INVERTER LOCATED IN ADMIN BUILDING. PERMIT FOR ADMIN BUILDING (1 OF 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54643	19041-10000-24710	4671 E WORTH ST	90063	14	135A233   232	5223002015	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/25/2020 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM				PC FOR A NEW APPROXIMATELY 208,057 SF  (WAREHOUSE & OFFICE BLDG WITH  ROOF TOP PARKING DECK). SERVICE SIZE IS 1600A, 277/480V, 3PH, 4WIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54644	11041-20000-14449	6141 W AFTON PL	90028	13	147A189   180	5546021014	R3-1XL	Central	Hollywood	Hollywood Studio District		1908.00	Electrical	Electrical	Apartment			07/12/2011 12:00:00 AM	07/12/2011 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	ADDRESS	34.0954	-118.32362	upgrade service to 600 Amps	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54645	12041-20000-11486	13452 W VENTURA BLVD	91423	5	165B157   802	2373007005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	34.14711	-118.42667	T.I. / ENERGYexist. permit  12041-20000-06306	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54646	18041-10003-46963	3246 S BARBYDELL DR	90064	5	123B165   645	4316025009	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.0332	-118.40325	"DELTA ""2"" Changes to approved plans. Service Upgrade to 400Amp & Installing a New 200Amp Fuseable disconnect with Type ""T"" fuses. All panels and disconnects are rated for 22KAIC."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54647	11041-20000-18845	11845 W OLYMPIC BLVD #500 W	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM			PC Approved	09/06/2011 12:00:00 AM	PIN	34.03325831	-118.45191172	PLAN CHECK T24 ENERGY/EMERGENCY TENANT IMPROVEMENT #500W.  PERMIT UNDER #11041-30000-16068	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54648	15041-10000-04910	2900 E OLYMPIC BLVD	90023	14	120A221   148	5170025001	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.02224	-118.21557	Plan check for Title 24 only. Project site is an existing building. Total lighting area = 4,656 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54649	16041-10000-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	PIN	34.2363795	-118.55851216	PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE 214 UNITAPARTMENT WITH RETAIL CORE & SHELL. 4 FLOORS OF RESIDENTIAL OVER 2 FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL.  THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMPS, 4000 AMPS, AND 1000 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54650	15041-20000-35921	11244 W ERWIN ST	91606	2	177B173   442	2336031003	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.18294	-118.37633	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter, and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54651	18041-20001-20186	22704 W SYLVAN ST	91367	3	177B097   158	2039019026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM			PC Approved	06/26/2018 12:00:00 AM	ADDRESS	34.18442	-118.62132	supplemental for fee expeditePlan check for a PV1 roof-mounted PV system. System size is 15.2KVA consisting of (2) inverter - solivia 7.6TL, (53) modules, and (1) load centers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54652	17041-10000-05078	3825 W DON FELIPE DR	90008	8	114B181   376	5032021025	[Q]RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.00771	-118.34215	Plan check for Title 24 only in existing space, remove outdoor HID lighting fixtures and replace with new LED fixtures. Total area:49300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54653	13041-10001-35505	15801 W MOORPARK ST	91436	5	168B141   508	2261012016	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Apartment			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/23/2014 12:00:00 AM	ADDRESS	34.15688	-118.47729	Expedited RSES plan check per applicant request.{{PV1, Install 4.75 kW DC roof-mounted solar array for a two story house, interconnect with main service panel.(1) Transformerless inverter(1): Solaredge SE 5000A-US. (19) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54654	09041-20003-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			PC Approved	04/07/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 26	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54655	13041-10000-23385	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.06307	-118.2	FA FOR USC USC CLINICAL SCIENCES CENTER. TYPE 1 - FULLY SPRINKLERED. b OCCUPANCY. 2 STORIES + BASEMENT. 154 DEVICES, 1 PANEL, 1 ANNUNCIATOR AND 3 BATTERY CABINETS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54656	18041-30000-46872	10880 W WILSHIRE BLVD #980	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.05885	-118.44283	PC FOR ENERGY ONLY, TENANT IMPROVEMENT TO EXISTING OFFICE SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING. (TOTAL SQ. FT. 4920 SQFT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54657	15041-20000-36546	300 S GRAND AVE 9th & 10th-Floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for power and energy. Project site is an existing commercial, high-rise building. Project scope is a tenant improvement to the 9th and 10th floor. Total lighting area = 41,206 sq. ft. (9th floor is 20,286 sq. ft. and 10th floor is 20,920 sq. ft.).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54658	14041-10001-05692	3821 N MONTEREY ROAD	90032	14	145-5A229 288	5302028034	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			Reviewed by Supervisor	03/12/2014 12:00:00 AM	ADDRESS	34.09125	-118.18834	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(10) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER:  POWER-ONE AURORA PVI-3.0-OTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54659	18041-10000-19114	3667 S MENTONE AVE	90034	5	120B161  1081	4314009015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.02268	-118.40734	New Fire alarm system on a new 3-story, 10-unit apartment building with a basement parking garage.  (1) FACP, (41) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54660	13041-10000-04811	375 N LA CIENEGA BLVD 1-125	90048	5	138B173    80	4337012068	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.07806	-118.37692	FA INSTALLATION 5 STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54661	19041-10000-00356	251 W MANCHESTER AVE	90003	11	096B149   731	4116018007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	33.96025	-118.27758	PLAN CHECK FOR TITEL 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54662	11041-20000-12539	1638-1640 N LAS PALMAS AVE	90028	13	148-5A185 182	5547014041	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.10082	-118.33601	"PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT OF EXISTING RESTAURANT. ""COMPLY WITH DEPARTMENT ORDER effective date07/31/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54663	13041-20000-20014	7540 S WHITLOCK AVE	90293	11	093B149   100	4117004003	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	33.95205	-118.44555	pv1 single family dwelling total system size 5.2 kw using transformerless inverter nonstandard plan. using total of 16 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54664	13041-20001-22744	1946 S WESTHOLME AVE PV-1	90025	5	129B157   385	4317005012	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.05146	-118.42717	EXPEDITE FEE.PV-1. Plan check due to 50A branch circuit. ONe 6.5kW inverter and one 2.5kW inverter for 9kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54665	17041-20000-12005	415 S BERENDO ST	90020	10	135B197   540	5502011024	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.06681	-118.2943	PV2.  Install roof mounted PV system sized 40.0 kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54666	14041-10001-01939	5108 E YORK BLVD	90042	14	156A225   354	5478006012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Info Complete	02/19/2014 12:00:00 AM	ADDRESS	34.12087	-118.20441	NEW LIGHTING FOR A TAKE OUT RESTAURANT. T24 PLAN CHECK AND ADDITIONAL PERMIT PER INSPECTOR REQUEST(((((((((((((((((INSTALL OUTLETS UNDER EXISTING CIRCUITS.  (PERMIT #14041-10000-01939))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54667	14041-10002-32975	8559 W EDWIN DR	90046	4	156B169   341	5565044010	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.12115	-118.38741	Fee is $0.00 due to Senate bill 1222.Change to approved set by replacing (2) Uno-8.6TL-OUTD Powerone inverters to (3) PVI-6000OUTD, and strings are being rearranged; Number of modules remain the same.(((Fee is $0.00 due to senate bill 1222.  (PV1.  Install 20 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54668	11041-10000-19776	1756 E 23RD ST	90058	9	117A213   141	5167015020	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.0157	-118.24108	TI IN AN EXISTING COMMERCIAL AREA IN THE NORTH EAST CORNER OF THE BUILDING. PLAN CHECK IS FOR ENERGY CALCS.  EXISTING PERMIT 11041-10000-17402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54669	11041-20000-23068	4734 N FARMDALE AVE	91602	2	168B169   571	2354013050	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	02/27/2012 12:00:00 AM	ADDRESS	34.15678	-118.38105	Plan check 3.45KW Enphase Microinverter solar photovoltaic system single family dwelling. Variance to install M215 prior to testing agency listing or approval has been filed.  The are two branch circuits in the system.  The wiring from the garage to the house is an overhead span and shall comply with CEC 225.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54670	17041-20000-14200	14435 W SHERMAN WAY #110-113	91405	2	183B149    39	2217003046	C1-1VL, C2-1VL, P-1VL, QP-1VL, [Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.20136	-118.44753	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement to a dental office. Total lighting area = 3,359 sq. ft.Note: Building permit has been issued under 17016-30000-11059	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54671	17041-10000-21393	523 W 6TH ST 9TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	TI TO DEMO (E) COMMON CORRIDOR SUSPENDED CEILING AND REPLACE WITH NEW SUSPENDED CEILING W/ NEW GRID, TILE, LIGHTING 1,431 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54672	17041-10001-18659	1642 S CIMARRON ST	90019	10	126B189   506	5073019022	R2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.04228	-118.31531	EXPEDITE PER APPLICANT REQUEST. ((((((PV1. SCOPE INCLUDES A NEW PV SYSTEM WITH A 5.8KVA POWERWALL BATTERY. TOTAL SYSTEM SIZE IS 3.0KWac.(12)MODULES-LG# LG315N1C-Z4(1)INVERTER-ABB# PVI-OUTD-S-US-Z-A(1)200A SUBPANEL(1)TESLA AC POWERWALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54673	19041-20000-24554	704 S HARTFORD AVE PV	90017	1	130-5A205 165	5143009002	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.05179	-118.26737	Install roof mounted PV system sized 10KW AC on a commercial bulding interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54674	19041-10000-46441	22321 W HART ST	91303	3	183B101   294	2024037002	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.19782	-118.61326	NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 10.73KW DC/ 10 KW AC, WITH A CENTRAL INVERTER (SE10000-US), 37 MODULES ( TWINPEAK 2 SERIES),  AND 37 SOLAREDGE OPTIMIZERS (P320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54675	13041-10000-02940	19339 W VICTORY BLVD #35	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Approved	02/05/2013 12:00:00 AM	ADDRESS	34.18678	-118.5549	"""COMPLY WITH DEPARTMENT ORDER effective date 2/13/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"" INSPECTOR ANGEL SINDAYENPC FOR ENergy T24. TI TO EXIST RETAIL  UNLEASEHED (PET STORE) taking over blockbusters - separate building in mall complex."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54676	16041-10000-31873	1256 W 7TH ST	90017	1	130-5A205 150	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	04/18/2023 12:00:00 AM	ADDRESS	34.05216	-118.26774	FULL PC FOR POWER AND ENERGY.  THE ADDED LOAD IS GREATER THAN 400AMP.SCOPE INCLUDES  ENERGY AND POWER. INCLUDING NEW PANELS AND CIRCUITSTOTAL AREA IS 25779 SQ.FT.Interior remodel of existing hotel. b#14016-10000-12619	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54677	19041-10001-24186	6605 S OCEAN FRONT WALK	90293	11	096B149   322	4116002047	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	33.95981	-118.45206	"DELTA ""1"" CHANGES TO APPROVED PLANS. INSTALLING A NEW ""LOAD CENTER"" PANEL. PLAN CHECK ONLY. PERMIT IS REQUIRED.<<<PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND TESLA SOLAR ROOF MODULES, (98) ROOF MODULES (1)7.6 KW INVERTER. TOTAL SYSTEM SIZE IS 6.7925 KWDC AND 7.6 KWAC.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54678	14041-20000-23212	16226 W BALLINGER ST	91343	12	201B137   989	2677020045	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.24372	-118.48608	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(18) KYOCERA TSM-255 MODULES(18) SOLAR EDGE POER OPTIMIZERS P300(1) SOLAR EDGE SE 3800 TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54679	19041-10000-53016	11920 S CENTRAL AVE	90059	15	084B209   716	6148014012	C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Info Complete	12/23/2019 12:00:00 AM	ADDRESS	33.92427	-118.25413	PLAN CHECK FOR TITLE 24 ONLY. SCOPE OF WORK INCLUDES ALTERNATIONS TO LIGHTING FIXTURES. (INDOOR LIGHTING ONLY; OUTDOOR LIGHTING EXCLUDED FROM SCOPE OF WORK) TOTAL AFFECTED AREA: 2263 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54680	19041-10000-10060	888 S VERMONT AVE	90005	10	132B197   748	5077024038	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM			PC Approved	03/20/2019 12:00:00 AM	ADDRESS	34.05601	-118.29141	CHANGE OF LIGHTING SYSTEM IN THE PARKING STRUCTURE OF A COMMERCIAL BUILDING UNDER CONSTRUCTION AND PERMITTED ON 15041-10000-26870 ON 4/19/2017.PLAN CHECK IS FOR TITLE 24 REVISIONS FOR THE LIGHTING IN THE PARKING STRUCTURE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54681	13041-20000-01456	7227 N VAN NUYS BLVD #400	91405	6	186B149   837	2218024013	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.20225	-118.44905	Plan check for power and energy. TI for a grocery store. SUPER KING MARKET NO.6. 52834sqft. Equipment count per applicant---PLEASE VERIFY FOR FINAL FEE PERIOD---> Permit fees have been computed under final fee period.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54682	17041-20000-08330	19731 W VANOWEN ST	91306	3	183B117  1051	2135022046	(Q)C4-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Intent to Revoke	06/15/2017 12:00:00 AM	ADDRESS	34.19397	-118.56313	Plan check for energy only. TI to existing retail (Marshall's). New lighting in storage room and offices. 672sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54683	14041-10000-20160	11100 W SANTA MONICA BLVD #1910	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	permit to be pulled at EPC counter only . plan check for energy only TI (E) OFFICE SPACE WITH 2013T24 STANDARDS. hirise with emergency lighting installed. Suite #1910	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54684	18041-10000-47219	2729 E CESAR E CHAVEZ AVE	90033	14	127-5A225  54	5177032027	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.04485	-118.20297	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54685	11041-20000-27242	1990 S BUNDY DR #540	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	02/09/2012 12:00:00 AM	ADDRESS	34.03419	-118.45559	energy plan check # 540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54686	13041-20000-18250	9201 N JELLICO AVE	91325	12	198B129   325	2766007020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.23795	-118.51914	New Enphase PV rooftop PV System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54687	12041-10000-01340	241 S RIMPAU BLVD	90004	4	135B185    73	5515008015	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.06934	-118.33047	New roof mounted 17.9KW photovoltaic system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54688	09041-20001-16690	7764 N SAN FERNANDO ROAD UNIT #3	91352	6	189B177   528	2405001017	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	03/17/2010 12:00:00 AM	ADDRESS	34.21233	-118.35805	supplimental permit to existing permit adding 4 additional circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54689	19041-10001-30213	3400 W OLYMPIC BLVD 2nd floor	90019	10	129B193   344	5081031025	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM			PC Approved	11/01/2019 12:00:00 AM	ADDRESS	34.05245	-118.31249	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REPLACING DIMMERS IN OFFICES <100 SF - AFFECTED CHANGES ARE CLOUDED UNDER DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54690	17041-20001-18891	649 S WALL ST	90014	14	127-5A211 227	5148023018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	12/31/2020 12:00:00 AM	ADDRESS	34.04256	-118.24822	POWER ONLY PLAN CHECK FOR DELTA 22 CHANGES TO APPROVED SET. THE CHANGES INCLUDE THE FOLLOWING: REMOVE FIREPUM AND FIRE PUMP SECTION FROM DISTRIBUTION BOARDREVISE & ADD NEW CIRCUITS TO THE SYSTEM.UPDATE LOAD CALCULATIONS. CONNECT STAIRS LIGHTING TO 2 EM CIRCUITS FED FROM EM BACKUP INVERTERNO ELECTRICAL CHANGES TO MEDICAL PATIENT AREAS. Plan check for power and energy. Project site is a new 7-story building: 5 levels of residential and medical office over 2 levels of podium medical office and parking. Project scope is a core and shell. Total lighting area = 12,641 sq. ft.Note: Building application has been generated under 16010-10000-03925	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54691	14041-20000-20259	7149 N CASTLE PEAK DR	91307	12	186B085   138	2031004068	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.20205	-118.6617	Standard plan: 4.2KW PV1 roof-mounted system with (20) Trina Solar TSM-255p modules and one Power-One Aurora PVI-4.2-OUTD transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54692	19041-10000-33126	6223 W 96TH ST TEMP	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	08/14/2020 12:00:00 AM	ADDRESS	33.94902	-118.3934	INSTALLATION OF TEMPORARY TRAILERS IN THE CONSTRUCTION OF THE ITF WEST FACILITY AT LAX FOR THE LAMP PROJECT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54693	17041-10000-39631	7913 N WHITE OAK AVE	91335	12	189B129   691	2101037008	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.21427	-118.5188	PC FOR ROOF MOUNTED PV ON SFD SYSTEM  9.28 KWDC / 10 KWACSCOPE INCLUDES  29 MODULES WITH OPTIMZERS (P400) AND SINGLE INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54694	13041-20000-30105	601 S FIGUEROA ST 14th floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	Change to lighting in an existing high rise office building.  Load is less than 400 amps per applicant.  PLAN CHECK for Energy, with Emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54695	18041-20000-07141	5244 N LEGHORN AVE	91401	4	171B161   380	2345017082	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.16601	-118.41581	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 15.2KVA CONSISTING OF 2 INVERTER(SE7600H-US) AND 55 PANELS WITH P400 OPTIMIZERS$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54696	14041-20000-13629	117 N SERRANO AVE	90004	10	138B193   871	5517010009	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.07417	-118.30688	PV1. STANDARD MICROINVERTER PLAN. SYSTEM SIZE 3.4 KW(16) SE F275  MODULES(16) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54697	14041-20000-26347	925 W WEST 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.0239	-118.28647	PC FOR EMERGENCY LOADS ONLY. PER APPLICANT, BUILDIN USE IS 24 HOUR OPERATION, EXEMPT FROM SHUT OFF. REFEED EXISTING LUMINAIRES TO EMERGENCY SYSTEM TO PROVIDE PROPER EMERGENCY ILLUMINATION. NO ENERGY CHECK REQUIRE, NO CHANGE IN ENERGY DENSISTY. PC FOR EMERGENCY LOAD CAL ONLY TO ENSURE GENERATOR CAN HANDLE ADDITIONAL LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54698	16041-10000-43804	3630 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	34.02045	-118.37799	PC FOR FA SYSTEM - ALL DEVICES RUNNING OFF MAIN PANEL. TOTAL OF 31 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54699	14041-10001-09088	2040 N COMMONWEALTH AVE	90027	4	150B201   432	5591009021	R2-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM			PC Approved	05/05/2014 12:00:00 AM	ADDRESS	34.10885	-118.28511	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 2 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE3000A-US-ZB-U.(8) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54700	19041-10000-06685	5220 N HARMONY AVE	91601	2	171B177   550	2416010066	[Q]R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			02/25/2019 12:00:00 AM			Reviewed by Supervisor	03/06/2019 12:00:00 AM	ADDRESS	34.16552	-118.36633	PC FOR A NEW FA SYSTEM TO AN EXISTING 3 FLOOR  APARTMENT BLDG . SYSTEM CONSIST OF 1 FACP, 10 POWER SUPPLIES, AND 325 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54701	16041-20000-27779	13192 W BRACKEN ST	91331	6	198B157   817	2625009016	RS-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Expired	09/20/2018 12:00:00 AM	ADDRESS	34.23686	-118.42014	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (13) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54702	19041-20000-15993	2407 N NORTH BROADWAY	90031	1	138A221    59	5204004014	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	34.07379	-118.21661	PV3.  Install 27.01 kW DC / 21.608 kW AC-CEC roof mounted grid tied PV system on commercial building.  (74) modules with (2) 11.4 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54703	13041-20000-19970	15826 W VALERIO ST	91406	6	186B141   572	2206030029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Expired	08/27/2015 12:00:00 AM	ADDRESS	34.20464	-118.47817	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3 KW. USING 19 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54704	14041-20000-01342	13172 W VAUGHN ST	91331	7	213B157   100	2524007002	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Expired	03/01/2016 12:00:00 AM	PIN	34.28340913	-118.41953629	PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54705	13041-10000-06062	888 S FIGUEROA ST 18TH	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM			PC Approved	03/07/2013 12:00:00 AM	ADDRESS	34.0465	-118.26225	REMODELING EXISTING OFFICE TENANT SPACESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENC CKTPERMIT TO BE OBTAINED AT ELECTRICAL COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54706	10041-10000-20583	12312 W OLYMPIC BLVD	90064	11	123B149   659	4259025008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.03166	-118.45665	750 kva stand by gen  set supplying  an UPS and CRAC units located at  adjacent building ( 12200 W Olympic ). it will require disconnect switch at the other bldg for fire department shut off.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54707	18041-10000-36873	1621 S SOTO ST	90023	14	118-5A221  20	5169015004	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	09/27/2021 12:00:00 AM	ADDRESS	34.02038	-118.22047	New 1,200 Amp 277/480V service. Core & Shell ONLY. 400Amp for 3 future warehouses each.  Replacing Damaged equipment. No Connected Load. All future TI's require complete Plan Check.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54708	16041-10000-44018	8323 N WOODMAN AVE	91402	6	192B153   694	2637029011	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.22246	-118.43295	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 20874.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54709	17041-10000-07338	660 S FIGUEROA ST #1940	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR ENERGY. T.I. OFFICE IN A HIGH RISE BUILDING. TOTAL AFFECTED AREA 1724 SQ FT.B# 16016-10000-81021	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54710	19041-10000-47298	11462 N JEFF AVE	91342	7	213B177   100	2529016018	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.2786	-118.36545	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 11.84KWdc (11.66KWac) USING 37 SPR-320E-WHT-D MODULES, 37 Enphase IQ7X-96-2-US MICROINVERTERS.CONNECTED TO AN UPGRADED 225Amp SERVICE.UPGRADED SERVICE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54711	13041-20000-05787	11700 W NATIONAL BLVD STE G	90066	11	120B153  1083	4250001026	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Approved	04/17/2013 12:00:00 AM	PIN	34.02218411	-118.43889497	Plan check for energy and emergency lighting. N.Y. Bagel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54712	13041-10000-28645	8560 N RUDNICK AVE	91304	12	195B101   456	2004019019	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.22684	-118.61291	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 4.0 kW DC.(16) CANADIAN SOLAR CS6P 250P(16) ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54713	17041-20001-38957	3627 N CODY ROAD	91403	4	159B145    65	2278024004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.1361	-118.46394	1/25/2018changes to an approved set of plans.  Changes to match field conditions.This is plan cvheck only.(((Installation of 27 kWh energy storage system for SFD.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54714	10041-20000-13791	15031 W RINALDI ST	91345	7	213B145    64	2664022022	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1066.06	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	07/23/2010 12:00:00 AM		Permit Finaled	09/13/2010 12:00:00 AM	ADDRESS	34.27918	-118.46029	This plan check is for title 24 energy only. Plan checked under 2008 T-24 Energy code, plans has 2005 T-24 compliance forms. No work on power in exam room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54715	13041-10001-27866	4232 N RHODES AVE	91604	2	165B165   816	2367007006	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.14776	-118.40288	Expedited plan check per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54716	11041-20000-08188	2029 S CENTURY PARK EAST 39th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	08/30/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. to existing high rise building of entire 39th floor.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54717	19041-10000-07855	20929 W VENTURA BLVD UNIT 39	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTING AND EXIT SIGN TO EXISITNG RETAIL SPACE FOR FUTURE TENANTPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54718	18041-20001-19770	1738 S CHASTAIN PKWY EAST	90272	11	138B121   131	4431041019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.07423	-118.54729	Expedited plan check fee. PV1.  Install 16.1 kW DC roof mounted grid tied PV system.  (46) modules with 3.8 and 10.0 kW rated string inverters.  Main breaker derate.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54719	13041-10000-12289	6100 N SEPULVEDA BLVD	91411	6	177B145   597	2242025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.18076	-118.46437	TI to an existing bldg for the opening of a Dollar Tree store.  Newly connected load < 400 A.  Title 24 plan check only.Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54720	15041-20000-35897	7210 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.2485	-118.28897	TI on an (E) retail, PC for Energy only. Total area 2300 sq.ft, two new 100A (Bus) panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54721	16041-10000-34232	4905 S ASCOT AVE	90011	9	111A211   258	5107029001	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	10/29/2016 12:00:00 AM	ADDRESS	33.99822	-118.25007	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(9)MODULES-KYOCERA# KU2656ZPA(1)INVERTER-PVI-3.0-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54722	16041-10000-39883	2911 W SAN FERNANDO ROAD	90065	1	153A213  1265	5457005013	R1-1-CDO, [Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.11262	-118.24301	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURS. TOTAL AREA 74800 SQ FT. PC FOR T24 COVERED AREAS AND PERMIT WILL BE ISSUED FOR ENTIRE SCOPE, INCLUDING T24 EXEMPTED ATHLETIC FIELD.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54723	15041-20000-24352	22845 W CALVERT ST	91367	3	177B097   375	2039014042	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Refund in Progress	08/31/2016 12:00:00 AM	ADDRESS	34.18115	-118.62484	"""0$ permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 21.2 KW. 400amp main panel with 200 amp main and 100 amp solar."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54724	17041-20001-38130	11335 W DONA DOROTEA DR	91604	2	156B169    99	2381007029	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.12722	-118.38066	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.Total system size: 15.2kW ungrounded.(2) 7.6kW SolarEdge inverters(57) 330W pv modules.(57) 400W power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54725	17041-10001-07060	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			Reviewed by Supervisor	03/21/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	Supplemental for changes to approved set. Scope includes changes in FA circuits and addition of CI cable for 8th to 12th floor. All changes clouded under delta 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54726	12041-10001-16520	645 S LA BREA AVE	90036	4	135B181   770	5508007022	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/10/2012 12:00:00 AM	ADDRESS	34.06359	-118.34421	Change the approved plan. Change the T24 and lighting. EPC is for delta 3 change. (((((((((((((((New retail space in an Existing Commercial Building.  New 800Amp Service.  Plan check for Power and Energy.))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54727	14041-10000-30306	700 N NORTH FARING ROAD	90077	5	144B153   738	4358007025	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.0893	-118.43496	New fire alarm system for a middle school, total (1) fire alarm panel, (1) power supply, and (36) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54728	15041-10000-16397	12515 W OSPREY LANE #1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	33.97893	-118.41131	((((5/28/2015))))PV1 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 1  SIZED 1.38KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19525	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54729	18041-10001-31030	6951 S CENTINELA AVE	90045	11	105B165   931	4211011063	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM			PC Approved	09/21/2018 12:00:00 AM	ADDRESS	33.98326	-118.39974	SCOPE OF WORK INCLUDES REMOVAL AND REPLACEMENT OF EXISTING RECESSED LIGHTS, RECEPTACLES AND SWITCHES LOCATED AT THE COACHES LOCKER ROOM, OPEN OFFICE AND CONFERENCE ROOM. PLAN CHECK FOR ENERGY ONLY TO COACHES LOCKER ROOM TOTAL SQ. FT. 280.PERMIT FEES HAVE BEEN PAID FOR UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54730	18041-10000-07540	360 E 2ND ST 3RD FLR.	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	T- 24, INTERIOR T.I. TO THE 3RD FLOOR OF AN EXISTING SPACE FOR SUITE 300 & 325. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 7011 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54731	18041-10002-23447	1035 N SWARTHMORE AVE	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	"Replacing the ""LOST PLANS"".Plan check only.  Permit Number: 18041-10000-23447<<<NEW 61.05 KW PV SYSTEM WITH 185 PV MODULES ON THE ROOF.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54732	17041-20000-09067	12700 W VAN NUYS BLVD Bldg 3	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	Plan check for a PV2 roof-mounted PV system. System size is 3 kWac and consist of (1) inverter and (8) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54733	15041-10000-29015	2043 S IMPERIAL ST	90021	14	118-5A217  59	5167012026	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			Reviewed by Supervisor	09/16/2015 12:00:00 AM	ADDRESS	34.0202	-118.23157	UPGRADE UNDERGROUND SERVICE TO 800A; LOADS REMAINING THE SAME	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54734	16041-30000-15918	4600 N COLDWATER CANYON AVE	91604	2	168B161   906	2362019013	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			05/05/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.15402	-118.4136	Plan check for a fire alarm system for a 4-story, 32-unit apartment building. System consists of (1) FACP, (1) annunciator, and (123) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54735	18041-10001-29772	10250 W SANTA MONICA BLVD #2720	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"DELTA 3 CHANGES TO THE APPROVED PLANS. <<<Full plan check for the first time T.I virtual reality entertaininment space ""Dreamscape Immersive"" within Westfield Century City Mall. Scope includes new lighting and equipment with a total area of 7,783-SQ FT. (Tailored Method)>>>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54736	13041-10000-24803	5834 E EATON ST	90042	14	157-5A229 318	5485018006	RE11-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			Verifications in Progress	01/23/2014 12:00:00 AM	ADDRESS	34.12474	-118.19078	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 3.75 KW DC AND 3.8 KW AC. [MODULES: TRINA SOLAR # TSM-250PC05/PA05.18 |||| INVERTER: SOLAR EDGE # 3800A-US |||| POWER OPTIMIZER: SOLAREDGE # OP250-LV]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54737	14041-10000-20052	675 S CENTRAL AVE	90021	14	126A213   700	5147034001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	PIN	34.0374039	-118.24094014	Title 24 plan check only.  Total rea = 5,051 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54738	18041-10000-39412	270 S WESTERN AVE	90004	10	135B193   202	5517007021	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2114.10	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.06919	-118.30891	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54739	18041-30000-41475	11115 W MCCORMICK ST	91601	2	171B173   389	2350018915	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	07/06/2020 12:00:00 AM	ADDRESS	34.16605	-118.373	INSTALL NEW FIRE ALRM SYSTEM  FOR NEW 5 STORY 14 UNIT MIXED USE BUILDING. (1) FACP, (74) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54740	12041-20000-11264	12148 N EDGECLIFF AVE	91342	7	216B145   200	2611037015	RA-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2012 12:00:00 AM			PC Info Complete	05/16/2012 12:00:00 AM	ADDRESS	34.29171	-118.46189	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM using Enphase inverter model 215. permit is on 12041-20000-09208 and 12041-20001-09208.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54741	14041-10000-14882	12655 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	33.97753	-118.41457	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54742	16041-30000-42283	18409 W SANDRINGHAM CT	91326	12	213B125   294	2870016017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.28072	-118.53381	Plan check for a PV1 roof-mounted PV system. System size is 3.3 kWac and consists of (10) AC PV modules and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54743	10041-10001-06707	6600 N TOPANGA CANYON BLVD #49A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/28/2010 12:00:00 AM			PC Approved	04/28/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	Changes from previously approved plans.  Changes include general lighting and panel board.  Plan check for energy only.******TENANT IMPROVEMENT AT THE TOPANGA MALL- YOGURTSHOP BERICUPPLAN CHK IS FOR TITLE 24******	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54744	18041-30000-37454	350 S GRAND AVE #2850	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	PLAN CHECK FOR T24 ONLY, TI ON (E) OFFICE SPACES STE. 2850 ON 28TH FLOOR, TOTAL AREA: 2340 SQ.FT(B# 18016-10000-20633)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54745	19041-10000-53622	11014 W COHASSET ST	91352	2	186B173   566	2315018003	R1-1, R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.20652	-118.37085	[EPLAN] NEW PV1 INSTALLATION 10.23KWdc (10KWac) usinhy 31 SOLARIA POWERXT-330R-PX modules, 31 SUN20000-375W-USP0 POWER OPTIMIZERS & 1 SUN2000-10KTL-USL0 CENTRAL INVERTER. CONNECTED TO A 225 AMP NEW SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54746	15041-10000-03999	1136 W 10TH ST	90731	15	015B193   772	7458009016	RD2-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Closed	02/18/2015 12:00:00 AM	ADDRESS	33.73529	-118.30207	T24 only. remove hid light fixtures and replace with LED fixtures. total area 8792 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54747	17041-10000-11025	3610 1/2 S SOMERSET DR	90016	10	120B185  1202	5046002025	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.02364	-118.33724	PV INSTALLATION OF A NEW 2.320 KW DC/2.054 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A  DWELLING FAMILY HOUSE.(8) MODULES: SOLARWORLD 290 SW290 MONO(8) MICRO INVERTERS: ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54748	19041-20000-44640	5805 N SEPULVEDA BLVD	91411	4	174B145   102	2243001009	M1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	02/27/2020 12:00:00 AM		Permit Finaled	12/05/2020 12:00:00 AM	ADDRESS	34.17593	-118.46647	PV2,  Install 166.5 kW DC/ 161 kw AC carport mounted PV system.  (444) modules with (3) 33 kW rated inverters and (1) 62 kW rated inverter. $0 permit fees due to AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54749	18041-30000-41462	19191 S VERMONT AVE 9TH FL	90502	4	150B197   778	5589027010	R3-1XL	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLAN CHECK FOR T24 ONLY, TI WORK APPROXIMATELY 7700 SF OF THE TOTAL FLOOR AREA. POWER FED FROM EXISTING PANEL BOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54750	17041-20000-07435	725 S BIXEL ST bldg b	90017	1	130-5A207 631	5143004012	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.0501	-118.26506	ti to an existing commercial space. adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.  total square footage 4720.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54751	10041-10000-24969	848 W 7TH ST	90017	9	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	34.04904	-118.25956	TENANT IMPROVEMENTS OF EXISTING  7-11 STORE RETAIL  SPACE(~2946 S.F.) ;  NEW FINISHES, CEILINGS.  REMODEL RESTROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54752	12041-10000-10243	345 S GRAMERCY PL 1-46	90020	4	135B193   386	5504024081	R4-1	Central	Wilshire	Greater Wilshire		2117.02	Electrical	Electrical	Apartment			05/04/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	05/31/2013 12:00:00 AM	ADDRESS	34.06755	-118.31312	New Fire Alarm system for a new apartment complex.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54753	17041-10001-21343	1721 N NAUD ST	90012	1	136-5A219  25	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	04/14/2022 12:00:00 AM	ADDRESS	34.06911	-118.22594	CHANGES TO APPROVED SET.SCOPE INCLUDES NEW PROPOSED TEMP POWER RATED FOR 600A 120/240V,  ALL CHANGES ARE MARKED ON THE PLAN. PLAN CHECK FOR POWER AND ENERGY FOR TI (CHANGE OF USE FROM PAINT SHOP TO RESTAURANT). PLAN CHECK INCLUDES TEMPORARY  CONNECTION,  POWER WILL BE SUPPLIED BY 2 EXISTING SERVICES, 100A AND 400A. TOTAL AFFECTED AREA =  6672 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54754	10041-10001-23301	4376 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			04/21/2011 12:00:00 AM			PC Approved	04/21/2011 12:00:00 AM	PIN	34.09636699	-118.28547339	Delta C modification to originally approved set of plans which is a relocation of the service in the building.  New Del Taco Restaurant. New servise, Panelboard and circuits. Plan check is for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54755	14041-20001-05477	7076 W MAYDOCK PL	91042	7	204B201   440	2565007074	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.25645	-118.28564	Expedite Fee ONLY*****Roof mounted PV with 5KWdc.******	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54756	14041-10001-26626	100 S VOLADOR PL	90732	15	018B193   940	7559017029	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	33.74366	-118.31338	Expedite under customer's request(((PV1 microinverter, 9.89KW roof-mounted system including (46) Enphase M215 and (46) LG Electronics solar 270W modules  interconnecting through a load center.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54757	15041-10000-09041	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	Temp power plan check for CVS pharmacy ; main scope of work  including (1) 800-Amp service, and (1) 300kva transformer. PHASE A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54758	16041-10001-11732	5281 N EAGLE DALE AVE	90041	14	165A217    54	5680027003	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.14507	-118.22823	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{{PV1, INSTALL 13.52 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (52) MODULES: SOLARWORLD SW260 POLY(2) INVERTERS FRONIUS PRIMO 6.0-1 240V:}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54759	19041-20000-51429	1943 W ESTES ROAD	90041	14	163-5A223  39	5671005009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			Reviewed by Supervisor	01/02/2020 12:00:00 AM	ADDRESS	34.14385	-118.21089	PV1. INSTALL 11.16 KW DC PV SYSTEM WITH (191) TESLA TILE MODULES, (2) INVERTERS AND (2) ENERGY STORAGE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54760	19041-10001-12882	152 W PICO BLVD	90015	14	124-5A207  34	5133001003	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.03719	-118.26166	Plan check only. CHANGES TO ORIGINAL DESIGN. RESUBMITTAL FOR FULL PLAN CHECK. PERMIT FEES ARE PAID UNDER ORIGINAL. ((Full plan check for apower and energy.  Scope includes new lighting and equipment (1000-Amps service)  with a total area of 14,183-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54761	12041-20002-09659	2340 E OLYMPIC BLVD	90021	14	121-5A217 381	5167010008	M3-1-S	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.02561	-118.231	Modification to previously approved set of plans.  Upgrade service 800 amp service,  new feeders, new panels.  Site is in a Methane Buffer Zone        <<<<Relocation of 600A service. Plan check for power and energy. 12610 conditioned sqft. Single-story warehouse (no generator).>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54762	16041-20000-08836	18637 W VENTURA BLVD	91356	3	174B121   588	2160006010	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.17036	-118.53949	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. IMAGINE CENTER. 618 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54763	17041-10000-25478	19700 W VANOWEN ST	91306	3	180B117    62	2134002020	C4-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, West Los Angeles	Winnetka		1348.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.1936	-118.56251	PC for T24. Replace existing fixtures with LED fixtures. Total area 10700 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54764	11041-10002-20655	1403-1407 S ELKGROVE CIR BLDG 8	90291	11	111B145   666	4243002069	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.00106	-118.45876	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54765	15041-20000-07407	4870 N LANKERSHIM BLVD	91601	2	168B173   215	2353019010	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.15948	-118.37117	Plan check for Title 24 only. Project scope is a tenant improvement to an existing commercial space. Total lighting area = 2,750 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54766	17041-20000-12060	7501 N GLENOAKS BLVD	91504	2	186B181   296	2401042013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.04	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.20677	-118.34209	ti to an existing hotel.  adding new lighting new controls to new panels.  newly connected load less than 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54767	16041-10004-16012	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			08/10/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	PIN	34.04222127	-118.45848597	CHANGE TO AN APPROVED SET BY MODIFYING THE LIGHTING PLAN, MAINLY  IN CORRIDORS, AND ELEVATOR LOBBYS. CHANGES TO BREAKER SIZING, FEEDERS AND LOADING ON PANELBOARDS WITH NEW CIRCUITS. ALL CHANGES UNDER DELTA-5 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54768	19041-20002-29198	7362 N BOTHWELL ROAD	91335	3	186B117   626	2116003040	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM			PC Approved	09/09/2019 12:00:00 AM	ADDRESS	34.20459	-118.56079	09-09-2019 Changes to an approved set of plan, Changes include relocation equipment. All changes has been clouded. Plan check only Fee $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54769	10041-30000-11066	416 W 6TH ST	90731	15	015B201    91	7455004001	C2-1-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	33.73899	-118.28602	Installing light and power inside office area. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54770	14041-10000-24984	11818 W VOSE ST	91605	2	183B169   217	2321007023	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.19833	-118.39065	Title 24 plan check only.  Total area = 2,960 sq. ft.Remove HID light fixtures and replace with new LED fixtures.  LPD < .5 W/sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54771	17041-10000-16283	520 W ATHENS BLVD	90044	15	081B201    71	6117013004	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	33.92089	-118.28385	PV1 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTAL WITH OPTMIZERS.  (18) MODULES AND (1) SOLAR EDGE INVERTER. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54772	17041-10000-11376	1349 S ABBOT KINNEY BLVD	90291	11	108B145  1290	4239027016	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	33.99083	-118.46621	PC FOR TITLE 24 ENERGY ONLYTI FOR A RETAIL SPACE INSTALLING NEW LIGHTSTOTAL AFFECTED AREA 5299 sq.ft.Building app # 17016-10000-05146INTERIOR TENANT IMPROVEMENT TO EXISTING RETAIL SPACE. NEW NON-BEARING PARTITIONS, CEILING AND FINISHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54773	13041-10000-32938	12587 W CATHY ST	91342	7	228B161   670	2580006016	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.31953	-118.40785	PV1, Install  4.5 kw DC roof-mounted solar array for a 1 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 18 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54774	13041-20001-34244	1462 N LACHMAN LANE	90272	11	135B121    83	4420031001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.0621	-118.54941	((EXPEDITE FEES))PV1 FOR INVERTER/CHARGER WITH COMBINERS AND CHARGE CONTROLLERS. THIS SYSTEM ALSO CONSISTS OF A BATTERY BANK. TOTAL SYSTEM SIZE 8KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54775	13041-20000-26892	11651 W SAN VICENTE BLVD	90049	11	132B145   503	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.05412	-118.46401	PC FOR POWER AND ENERGY. RESTAURANT REMODEL. GREATER THEN 400A LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54776	07041-10002-11169	4550 W PICO BLVD	90019	10	129B185  1008	5083033004	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/06/2011 12:00:00 AM	ADDRESS	34.04842	-118.33486	New 2-level retail building and connected three level parking stucture with retail on top level. Three 3000 A services.  Core and shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54777	18041-20000-36268	3501 S TROUSDALE PKWY Basement-B4	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.02194	-118.28455	Tenant improvement to (E) commercial office spaces B4.  Plan check for energy. Total area: 668 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54778	15041-10000-16715	13315 W BROMWICH ST	91331	6	198B157   315	2625002018	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.24071	-118.4234	PV1.  Install 6.24 kW rooftop-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54779	15041-10000-05495	6304 W YUCCA ST 3RD FLR	90028	13	150A187   371	5546004027	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.10361	-118.32726	Energy plan check for a food store located in the third floor of a commercial building. total area is 380-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54780	15041-20000-25540	1999 S AVENUE OF THE STARS 12th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only. Project site is an existing high-rise commercial building. Project scope is a tenant improvement. Total lighting area = 13,370 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54781	19041-10000-29119	6363 W HOLLYWOOD BLVD	90028	13	148-5A187 154	5546005013	C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.10177	-118.32877	PLAN CHECK ONLY, PERMIT IS UNDER 19041-20000-19873TENANT IMPROVEMENT IN RETAIL/OFFICE SPACE; PERMIT HAS BEEN OBTAINEDPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTPLAN CHECK ONLY(((((((ADDING/REPLACING  ELECTRICAL EXISTING LIGHTS, OUTLETS, SWITCHES AND RECEPTACLES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54782	16041-20000-33577	12322 W COHASSET ST	91605	2	186B165   261	2307024***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.20654	-118.40137	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54783	17041-10000-04154	1509 S ABBOT KINNEY BLVD	90291	11	108B145  1400	4241036011	C2-1-O-CA	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	33.99035	-118.46434	TI TO RETAIL STORE. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54784	15041-10001-36565	7525 S BROADWAY	90003	9	099B201    49	6031010019	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	33.97113	-118.27849	T24. RECHECKING FOR LOST SET OF PLANS. PERMIT TO BE ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54785	11041-20000-12398	7000 W HOLLYWOOD BLVD 3rd floor	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM			PC Approved	06/15/2011 12:00:00 AM	ADDRESS	34.10137	-118.34182	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR INTERIOR REMODEL CORRIDOR ON THE 3RD FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54786	16041-10000-36108	800 WORLD WAY A1-16D4880	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	33.94305	-118.39757	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT  OF (E) FOOD & BEVERAGE CONCESSION AT LEVEL 3(PANDA EXPRESS). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 497 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54787	14041-10000-02426	528 E E ST	90744	15	030B209   843	7424005046	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	PIN	33.77567421	-118.25592409	Remove HID light fixtures and replace with new fluorescent fixtures in a retail space.  Title 24 plan check for fixture one-for-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54788	19041-20000-46836	1807 S STANFORD AVE	90021	14	121-5A209 128	5131005014	CM-2D-O-CPIO	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	34.02746	-118.25525	T24 PLAN CHECK FOR LIGHTS AND OUTLETS ONLY, TOTAL SQUARE FOOTAGE = 2012 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54789	19041-20000-09377	2930-2936 E CESAR E CHAVEZ AVE	90033	14	127-5A227 253	5180019048	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.04342	-118.20083	T24 PLAN CHECK FOR EXISTING DENTAL OFFICE, INSTALLING LED LIGHTS AND OUTLETS, USING EXISTING BRANCH CIRCUITS, TOTAL SQUARE FOOTAGE = 1898 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54790	12041-20000-14412	6221 N COLUMBUS AVE	91411	6	177B145   283	2242012017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	09/14/2012 12:00:00 AM	ADDRESS	34.1837	-118.4642	Enphase system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54791	17041-10001-08669	3350 W WILSHIRE BLVD	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	34.0615	-118.29586	Changes to approved set.  Change fire alarm wire schedule to specify CIC/MC Cable.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54792	16041-20000-41465	17400 W KLEE ST	91325	12	195B129   304	2768015025	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.23116	-118.51376	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54793	15041-20000-36328	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	03/24/2016 12:00:00 AM		Issued	03/24/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	$0 permit fee due to senate bill 1222 from 2012Plan check for PV roof mounted system. System size: 681kW AC with 2856 modules. 885kw DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54794	16041-10000-30965	1000 W 8TH ST	90017	14	129A207    78	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.04866	-118.26309	PLAN CHECK FOR POWER AND ENERGY FOR BLD R3,  A HIGH RISE MIXED USE, RETAIL, PARKING, AND RESIDENTIAL BUILDINGS (TOWER 3 (BLD R3) PART 1 OF 2). NEW RESIDENTIAL TENANT SPACES GROUND FLOORS, LEVEL 5 THROUGH LEVEL 25(APPLICATION FOR FLOORS 26 TO 59 IS ON A SEPARATE APPLICATION, BUT THE PLANS FOR BOTH APPLICATIONS IS ONLY ONE SET OF PLANS). TOTAL AFFECTED AREA IS 98,009 SQ. FT.ORIGINAL CORE/SHELL APPLICATION COVERS BUILDING R2 AND R3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54795	19041-20000-29368	11957 N LOUISE AVE pv1	91344	12	216B129   212	2606026033	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM			Reviewed by Supervisor	08/06/2019 12:00:00 AM	ADDRESS	34.28854	-118.51244	pv1install ground mount pv system sized 15.2KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54796	11041-10000-23705	12448 W BRADDOCK DR	90066	11	108B157  1555	4221006058	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.10	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	33.98877	-118.41951	one story fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54797	19041-20001-52394	20140 W SHERMAN WAY	91306	3	183B113    63	2135038015	(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	09/23/2020 12:00:00 AM	ADDRESS	34.20085	-118.57213	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54798	11041-10000-25014	601 W 5TH ST	90071	9	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	ADDRESS	34.05049	-118.25386	T.I. to an existing bank at ground level.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54799	14041-10000-11659	10700 W SANTA MONICA BLVD 309	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	Plan check for power and energy for first time tenant on third floor - fitness center.1850 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54800	17041-10001-39250	449 S MCCADDEN PL	90020	4	135B185   351	5507014014	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM			PC Approved	12/15/2017 12:00:00 AM	ADDRESS	34.06547	-118.3373	Changes to an approved set of plans.  All changes to reflect as built. All changes are clouded under delta 1. Also, relocating modules on the roof-layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54801	14041-10001-28581	4816 W FOUNTAIN AVE	90029	13	147B197  1139	5540015017	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.09524	-118.29387	220 device fire alarm system for a new apartment building.(((((((((((((((((  12-11-14 m.z  all system smoke detectors wither sounder baseses removed no other devices added.))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54802	13041-10000-09438	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM			PC Approved	04/12/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	T24 FOR EXISTING LOBBY SPACE FOR A NON HIGHRISE BUILDING. 815 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54803	19041-20000-07712	1550 S BROCKTON AVE 1-9	90025	11	126B145   708	4263034024	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Apartment			03/04/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	05/14/2021 12:00:00 AM	ADDRESS	34.04022	-118.46005	new apartment building 800 amp service.  plan check for power and energy.  (9) units all typical	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54804	17041-20000-02118	13435 W BURBANK BLVD	91401	2	174B157   542	2343015032	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			01/23/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.1723	-118.42571	Plan check for power only. Project site is an existing apartment building. Project scope is the replacement of all service distribution equipment and tenant and house panels due to damage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54805	16041-20002-44200	5170 N SEPULVEDA BLVD 140-170	91403	4	171A145    43	2263002041	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.16461	-118.46592	[[[7/3/17 CHANGES TO APPROVED SET. CHANGES TO T24 LIGHTING AND EMERGENCY LIGHTING]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54806	17041-20000-26301	8408 MAGELLAN LN	91343	12	192B141   234	2673019073	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consists of (15) AC PV inverters and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54807	15041-20002-35678	21850 W OXNARD ST	91367	3	177B105    80	2146006045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.17895	-118.60413	REVISIONS TO AN APPROVED SET OF PLANS.  REMOVING/ADDING LIGHT FIXTURES RELOCATING  EXISTING CIRCUITS.  PANELS EXISTING.  PLAN CHECK FOR ENERGY ONLY.  APPROVAL FOR CHANGES NOTED DELTA 8 THRU DELTA 12 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54808	16041-30000-15803	9200 N OAKDALE AVE 3rd Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 23,285 sq. ft.Note: Building application has been created under 16016-10000-09233	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54809	12041-10000-30649	14006 W RIVERSIDE DR 260	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	02/01/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	multiple owners. find correct APNT24.TI TO EXISTING RETAIL FOR NEW KIEHLS STORE. 1126SF space 260	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54810	13041-10000-34655	2143 S PONTIUS AVE	90025	5	126B153   812	4322025013	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.04001	-118.4388	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 4038 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54811	18041-20000-16475	14908 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29404	-118.45523	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54812	14041-20000-35054	12726 W FILMORE ST	91331	7	213B161   571	2532004002	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.27997	-118.40996	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(18) SUNPOWER 327W MODULES(1) AURORA PVI-6000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54813	17041-10000-37297	4005 N VERDUGO ROAD	90065	14	156A217    77	5459015013	[Q]C1.5-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			PC Info Complete	01/09/2018 12:00:00 AM	ADDRESS	34.12323	-118.23153	PC FOR POWER AND ENERGY FOR MEDICAL TI WITH SERVICE UPGRADE TO 600A. SCOPE INCLUDES NEW SERVICE 600A 277/480VNEW PANELS, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 3181 SQ.FT. INDOOR (NO OUTDOOR  LIGHTS WORK)B# 17014-10000-04932	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54814	12041-10000-20669	1314 N GORDON ST	90028	13	144B189    22	5545014031	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			08/30/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.09492	-118.31997	Plan check 1.26 KW roof mounted Photovoltaic system for a dwelling unit (Enphase M215 Microinverters). Multiple dwellings on property.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54815	18041-10000-02393	403 W ADAMS BLVD LOWMAN-BLDG	90007	9	121-5A205 317	5126017018	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02746	-118.27394	FULL PLAN CHECK: TENANT IMPROVEMENT TO AN (E) OUTPATIENT CLINIC. WORK INCLUDES ADDING PANELS, TRANSFORMERS, ATS, LIGHTING & RECEPTACLES. TOTAL AREA UNDER THIS SCOPE: 43,397 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54816	15041-10001-02011	12861 W OSBORNE ST	91331	7	204B161   806	2623031012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	34.25196	-118.41292	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 8.28 ROOFMOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.24 MODULES AND 2 INVERTERS.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54817	14041-20000-05183	4424 N BERGAMO DR	91436	5	165B137    59	2284016027	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Closed	07/15/2019 12:00:00 AM	ADDRESS	34.15206	-118.48686	PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 18.9KWAC. (E) 600A SERVICENote: Permit fee is $00.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54818	13041-10000-03964	170 N GLENDALE BLVD	90026	1	135A209   230	5160013013	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.0639	-118.25974	ON SITE ARE TWO BUILDINGS ( 170 AND 180 GLENDALE ) SERVICE IS UPGRADED TO SUPPLY BOTH BUILDINGS; ONLY THE BUILDING AT 170 GLENDALE WILL BE UNDER THIS PLAN REVIEW; PLAN REVIEW FOR THE OTHER BUILDING WILL BE UNDER A SEPARATE APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54819	15041-10000-42996	1875 CENTURY PARK EAST 3RD FLR	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Issued	12/31/2015 12:00:00 AM	PIN	34.06084104	-118.41471001	COMMON AREA RENOVATION. NEW LIGHITNG. PC FOR ENERGY ONLY T24. 3RD FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54820	14041-10001-28309	3650 E OLYMPIC BLVD	90023	14	118-5A227 227	5191024011	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM			PC Approved	11/26/2014 12:00:00 AM	ADDRESS	34.01861	-118.1992	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV2, INSTALL 343.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  RETAIL STORE(FOOD FOR LESS),  INTERACTION WITH THE MAIN PANEL. 66 STRINGS.(1347) MODULES: ZNSHINE ZXP6-60-255/P(11) INVERTERS:SOLAECTRIA PV1 28TL}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54821	15041-10001-13253	2978 W WILSHIRE BLVD 2nd  flr	90010	10	133-5A201  49	5077013013	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.06166	-118.28637	Power plan chk for  alterations in an existing medical office as required by electrical inspector((((((((((Energy plan check for an existing office T.I; Scope include new lighting and receptalces on the second floor of a 3-story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54822	17041-20001-17952	12909 W MAGNOLIA BLVD	91423	4	171B161   527	2345017014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM			PC Approved	06/13/2017 12:00:00 AM	ADDRESS	34.16503	-118.41422	6.13.2017 - Plan check for power only. Checking power due to feeder running through hazardous location.======TI TO AN EXISTING COMMERCIAL BUILDING (CONVENIENCE STORE) .  ADDING NEW LIGHTING NEW CONTROLS TO EXSTING EQUIPMENT.  FACILITY TO BE OPERATED 24 HOURS A DAY.  PLAN CHECK FOR ENERGY ONLY.PERMIT FEES COVERED UNDER APPLICATION NUMBER 16041-30000-40160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54823	15041-20000-01006	5999 N TOPANGA CANYON BLVD	91367	3	177B101   178	2146006013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.17887	-118.60554	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO DENTAL CLINIC. 2570 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54824	13041-20000-18383	735 S FIGUEROA ST LEVEL M3	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	Plan check for power and energy. Addition of loads to emergency panel and changes to lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54825	19041-10000-30791	9500 N SEPULVEDA BLVD	91343	7	198B145    46	2656010037	(Q)P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.24294	-118.46723	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54826	14041-20000-24275	517 S SPRING ST	90013	14	129A211   127	5149034005	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.04702	-118.25027	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING LIGHTING AND MECHANICAL EQUIPMENT ON EXISTING PANELS.  NEW CIRCUITS. 2338 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54827	19041-20000-03217	5638 N SEPULVEDA BLVD	91411	4	174B145   394	2243003026	C2-1VL-RIO, R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Apartment			01/28/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.17325	-118.46595	Replace receptacles, light switch and light fixtures in guestrooms and corridors.  Add new light fixtures at elevator lobby.  New circuit for washer and dryer.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54828	16041-10000-16311	600 S COMMONWEALTH AVE 13TH FLR	90005	10	135A201   145	5077006011	C4-2	Central	Wilshire	MacArthur Park, Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.06348	-118.28545	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO 13TH FLOOR OF HIGH RISE. SCOPE INCLUDES NEW LIGHTS RECEPTACLES FOR OFFICE SPACE ON THE 13TH FLOOR. TOTAL AFFECTED AREA IS 15400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54829	14041-10000-32366	8325 N LAUREL CANYON BLVD	91352	6	192B165   411	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	34.22241	-118.39768	Plan check for title 24. Modify one existing  cooler and replacement of refrigrator cases.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54830	17041-10000-02607	5550 W THORNBURN ST	90045	11	102B173   388	4103005038	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.97352	-118.37727	PC for title 24. Outdoor. Remove HID fixtures and replace with new LED fixtures. Area: 3,700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54831	14041-20000-11111	7224 S HOBART BLVD	90047	8	102B193  1530	6018002010	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	33.97373	-118.30772	PV1.  Install 3.060 kW roof-mounted PV system, interconnect with main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54832	17041-20000-11699	9102 N SEPULVEDA BLVD	91343	7	198B145   383	2656023027	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.23593	-118.46733	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO (E) RESTAURANT.  3750 SQFT.Building permit # 16016-20000-25528	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54833	12041-20000-06171	1103-1109 S BOYLE AVE	90023	14	123A219    19	5170007015	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.03162	-118.2203	Proposed 1 story with mezzanine (type III-B) warehouse building with accessory office (shell only).  Tenant improvement is an separate permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54834	13041-10000-22279	17440 W WEDDINGTON ST	91316	5	171B129   128	2257001015	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.1666	-118.51372	PV1.  INSTALL 10.29 KW DC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54835	14041-20000-01982	14162 W WEIDNER ST	91331	6	204B153   155	2617021004	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Expired	02/17/2016 12:00:00 AM	ADDRESS	34.25897	-118.44186	pv1 single family dwelling. total systemsize 3kw ac using transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54836	18041-10000-13328	11111 W SANTA MONICA BLVD 17th FL	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTROOMS.  (17th floor)BUILDING PERMIT # 18016-10000-10258	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54837	10041-10001-10058	1902 W PARK AVE	90026	13	139-5A207 209	5404002009	R3-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Apartment			05/25/2011 12:00:00 AM			PC Info Complete	07/27/2011 12:00:00 AM	ADDRESS	34.07616	-118.26168	THREE STORY TYPE-VA APARTMENTS OVER ONE STORY TYPE -1A SUBTERRANEAN PARKINGNOTE THAT VARIANCE TO SEPARATE THE FA PLANS IS REQUIRED AND PLAN CHK FEE NEEDS TO BE INCREASED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54838	11041-20000-19017	3111 N GLENDALE BLVD UNIT-C	90039	13	154-5A207 367	5435027020	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.11653	-118.26292	T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT TI. UNIT C	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54839	18041-10000-15956	8331 N BALBOA BLVD	91325	12	192B133   223	2690023189	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.22199	-118.50288	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54840	19041-20000-22243	22135 W ROSCOE BLVD LOT #36	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD.  SYSTEM SIZE IS 2.17 KW DC/1.68 KW AC.  SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54841	16041-10001-17698	7816 N SIMPSON AVE	91605	6	189B169   604	2310025031	R4-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM			PC Approved	05/23/2016 12:00:00 AM	ADDRESS	34.21268	-118.38874	Supplemental PC only to Permit #16041-10000-17698.  Add photometric floor plan for egress lightings.<<NEW FIRE WARNING SYSTEM IN MIXES USED BUILDING>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54842	11041-10000-05585	11951 W OLYMPIC BLVD #101	90025	11	123B149   526	4259023017	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	PIN	34.03265741	-118.45359065	NEW ADDITION COMMERCIAL SPACE IN SPACE  #101. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54843	15041-20000-02606	12492 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54844	18041-20000-47151	8756 N VANALDEN AVE	91324	12	195B121   324	2784003026	M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Issued	12/26/2018 12:00:00 AM	ADDRESS	34.22981	-118.54906	Plan check for emergency egress illumination for an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54845	17041-10000-23756	380 WORLD WAY PAX-Tunnel	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/13/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	instalation of new EFSO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54846	17041-10000-33125	13500 W HUBBARD ST	91342	7	225B157   825	2512001078	C4-1-K-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.30982	-118.42736	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 3700 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54847	13041-10000-14668	8714 W SKYLINE DR	90046	5	153B169   435	5564010010	RE15-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.11496	-118.38473	PV1 6.54KW XFRMLESS. 2 STORY HOUSE. NONSTD. ROOFMOUNT. ( INVERTER) powerone PVI-6000-OUTD-US. (20 MODULES)  SUNPOWER SPR-327NE-WHT-D	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54848	16041-20000-20339	410 W 7TH ST	90014	14	129A209   222	5144013021	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.04606	-118.25495	Plan check for power and energy.   Renovation of (E) commercial retail/office building.  Core and shell drawings. 2000amp 120/208 service Bldg permit filed under 16016-10000-10056	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54849	17041-10000-33441	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Issued	11/30/2017 12:00:00 AM	ADDRESS	34.02557	-118.3665	PC FOR METHANE MITIGATION SYSTEM. PROVIDING NEW ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54850	13041-10000-21459	1825 N BRONSON AVE 1-33	90028	13	150A191   280	5586027006	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			08/09/2013 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.10425	-118.31823	power and energy. APARTMENT BUILDING. REPLACING 40 PANELS, 33 of 40 ARE UNIT PANELS.  EXISTING BRANCH CIRCUITS TO REMAIN, RECEPTACLES TO BE REPLACED IN THE SAME LOCATION. Changes on plans include AFCI breakers, fully rated for 32kaic, and delta load calcs	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54851	19041-10000-50730	7166 W MELROSE AVE	90046	5	141B181   636	5525015003	C2-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	10/02/2020 12:00:00 AM		Permit Finaled	03/15/2021 12:00:00 AM	ADDRESS	34.08334	-118.34573	T.I PC FOR ENERGY ONLY. TOTAL AFFECTED AREA 2032sqft. SCOPE INCLUDES INSTALLATION OF NEW PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54852	16041-20000-20407	13930 S FIGUEROA ST	90061	15	075B201    24	6132044028	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Expired	08/13/2018 12:00:00 AM	ADDRESS	33.90432	-118.28254	"""0$ permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 40kW with 160 modules and 2 inverters(20.0kW) on commercial building ."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54853	12041-10000-10979	4503 S GLENCOE AVE 100-150	90292	11	105B153    96	4212007009	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM	ADDRESS	33.98462	-118.43524	T.I. to the first and second floors of an existing high-rise office building.  Change to lighting and new circuits.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit was previously pulled on a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54854	15041-20000-05894	4200 S OLIVE ST	90037	9	114A203   123	5111007025	RD2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	34.00723	-118.27932	Plan check for PV1 roof mounted 8.1kW with 36 module microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54855	13041-10001-32027	8425 N WEBB AVE	91352	6	192B165   338	2633007005	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.22357	-118.39509	][][EXPEDITED PER APPLICANT REQUEST ][][]PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING WITH (E) 200A MAIN. SYSTEM SIZE IS 5 kW DC WITH (20) MODULES RENESOLA JC250M-24/BB IN 1 STRING, AND (1) SOLAR EDGE INVERTER SB5000A-US WITH OPTIMIZERS OP250-LV ON NON-STANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54856	19041-10000-29414	1811 W PICO BLVD	90006	1	129A203   405	5137034021	CM-1	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	34.04586	-118.27921	REMODEL 1ST AND 2ND FLOOR OF 2 STORY BUILDING (URM BLDG).SERVICE 400A IS EXISTING; 4 EA 100 A  NEW PANELS AND CIRCUITS. 1ST FLOOR THERE ARE OFFICES; 2ND FL THERE ARE TWO DWELLING UNITSPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54857	12041-20000-21815	2990 N SILVER LAKE BLVD	90039	13	151-5A209 191	5437002901		East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM			PC Info Complete	10/02/2012 12:00:00 AM	ADDRESS	34.10939	-118.2559	"18"" X 12' 8"" X 3' 3""  SEWER GAS SCRUBBER FOUNDATION. NEW SERVICE, PANEL & CKTS. (work within classified area)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54858	15041-10000-23630	2828 N NEWELL ST	90039	13	148-5A213 150	5442017040	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.10192	-118.24324	ALTERATIONS IN AREA SUBDIVIDED INTO 3 TENAT SPACES-EACH WITH OFFICES AND WAREHOUSE AND RESTROOMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54859	14041-20000-20954	3500 W WILSHIRE BLVD	90010	10	132B193   108	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM			PC Info Complete	09/15/2014 12:00:00 AM	ADDRESS	34.06157	-118.30077	PC FOR POWER ONLY. NEW SERVICE AND DISTRIBUTION FOR FUTURE 2 STORY MINI MALL. EXISTING BUILDING WITH NEW ELECTRICAL CORE AND SHELL. PER BUILDING SUBMITTAL, PLAN CHECK FOR BUILDING EFFICIENCY BASED ON 2008 STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54860	19041-10000-36670	20335 W VENTURA BLVD	91364	3	174B113   533	2166033041	(Q)C4-1LD, (Q)P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.1693	-118.57652	Plan check for a PV1  3.8KW AC / 4.9KW DC roof mounted system. Scope includes (1) inverter, (14) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54861	19041-20001-47323	12325 W ERWIN ST	91606	2	177B165   292	2333009084	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.18318	-118.40173	12/12/19CHANGES TO APPROVED SET CHANGES TO PV BREAKER SIZE FROM 120 TO 125 AMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54862	16041-20000-38051	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR TOURNEAU INSIDE BLOOMINGDALES. 1177 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54863	18041-10000-27330	6171 N SEPULVEDA BLVD UNIT A2	91411	6	177B145   355	2242001026	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.18246	-118.46651	PC FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR  RESTAURANT TI.SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1033 SQ.FT B#18016-10000-23248	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54864	19041-20000-01367	4324 S VERMONT AVE	90037	9	114B197  1221	5020035018	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices		2317.10	Electrical	Electrical	Apartment			01/22/2019 12:00:00 AM	06/03/2022 12:00:00 AM		Issued	06/03/2022 12:00:00 AM	ADDRESS	34.00478	-118.29134	Plan check for power and energy.  Work includes an 800 amp service and a total lighting area of 7,619 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54865	17041-10000-17615	1720 N WILTON PL	90028	4	148-5A193  84	5544002066	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Issued	05/25/2017 12:00:00 AM	ADDRESS	34.1024	-118.31352	pv, installation of a new 4.55 kw DC/3.6 kw AC roof-mounted solar system on apartment building. (1) inverters: ABB PVI-3.6-OUTD-S-US   (14) modules: Solarcit SC325	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54866	13041-10000-04588	6543 N AMIGO AVE	91335	3	180B121   355	2127005010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.18971	-118.53871	PV1 solar panel installation for single story home. Total system size: 11.52 KW. [Inverter: Fronius IG Plus PV inverter. Model#: 10.0-1] [Solar Panel: Trina Solar. Model#: TSM-240 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54867	13041-20000-14766	22622 W VANOWEN ST	91307	3	180B097    33	2038020063	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.19355	-118.61959	NEW FIRE ALARM SYSTEM FOR SCHOOL. TOTAL DEVEICE 335 AND 1 FIRE ALARM PANEL W/ POWER SUPPLIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54868	18041-10000-39951	5781 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93503	-118.38291	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
54869	13041-20000-00752	15024 W MAGNOLIA BLVD	91403	2	171A147    24	2263004013	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00, 1289.10	Electrical	Electrical	Apartment			01/11/2013 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.16458	-118.46045	Fire alarm system for 5 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54870	18041-10000-27423	8345 N LAUREL CANYON BLVD	91352	6	192B165   367	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1210.10	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.22292	-118.39669	FULL PLAN CHECK TO A CHANGE OF USE FROM (E) RETAIL TO (N) MEDICAL OFFICE(DENTAL ) SPACE. SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS, LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3626.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54871	19041-20000-03357	957 N FIGUEROA TER 1-28	90012	1	136-5A213  93	5406024005	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			05/08/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.0678	-118.24372	CONDUIT ONLY IN DECK. FOR LOW VOLTAGE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54872	17041-10000-42586	21800 W OXNARD ST #800	91367	3	177B105    81	2146006046	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Issued	11/29/2017 12:00:00 AM	ADDRESS	34.17898	-118.60253	PC FOR NONSTRUCTURAL TI FOR OFFICE SPACE IN HIGH RISE FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 10469 SQ. FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. B# 17016-10000-34186	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54873	17041-20000-25044	13033 W VENTURA BLVD	91604	2	165B161   958	2375020028	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.14585	-118.41713	PLANCHECK FOR T24 ENERGY. CHANGE OF USE TO TANNING SALON. 1152 SQFT.BUILDING PERMIT # 15016-10001-12871	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54874	15041-20000-08242	17621 W SUPERIOR ST	91325	12	201B129   252	2755010026	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Expired	05/03/2017 12:00:00 AM	ADDRESS	34.24686	-118.51875	FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.Plan check for a PV1 roof-mounted PV system. System size is 12.8 kWac and consists of (64) modules, (3) inverters, and (1) 125-amp rated load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54875	19041-10001-18955	1719 W 265TH ST	90710	15	030B193    89	7411028027	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM			PC Approved	06/27/2019 12:00:00 AM	ADDRESS	33.78102	-118.30771	PLAN CHECK ONLY. DELTA ONE CHANGES TO AN APPROVED SET. UPDATING PLANS TO MATCH EXISTING CONDITION. (200A MAIN BRAKER INSTEAD OF APPROVED 150A).NO OTHER CHANGES PERMITTEDOriginal Scope:NEW ROOFTOP SOLAR SYSTEM CONSIST OF 17 MODULES (LG320N1K-A5) , 17 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 5.44KWdc and 3.8KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54876	12041-20000-10655	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			Corrections Issued	05/09/2012 12:00:00 AM	ADDRESS	34.17307	-118.59314	replace 100kw generator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54877	16041-20000-33682	4415 N WESTCHESTER DR	91364	3	166-5A109 121	2174013014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.15069	-118.58505	Plan check for a PV1 ground-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (51) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54878	12041-20000-05165	819 S FLOWER ST	90017	9	129A207   199	5144021032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.04688	-118.26067	energy plan check spa at mezzanine	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54879	18041-20001-48109	11050 W ARMINTA ST 1-110	91352	6	189B173   477	2314008041	(T)(Q)R3-1, (T)(Q)R3-1-CUGU, QRD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	Apartment			11/08/2019 12:00:00 AM			PC Approved	11/08/2019 12:00:00 AM	ADDRESS	34.21377	-118.37214	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CLOUDED DELTA 1 CHANGES ONLY. INCREASE TO NUMBER OF CONDUCTOR SETS ON FEEDER SCHEDULE ON SINGLE LINE, UPDATE TO VOLTAGE DROP VALUES, AND UPDATE TO SHORT CIRCUIT VALUES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54880	13041-20000-10598	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.01925	-118.37654	Install new 1500kw optional standby generator, new 1600 Amp swbd, new 150kva UPS Module.  New circuits and relocate circuits and sub panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54881	17041-10000-26113	9047 N MORNING GLOW WAY	91352	7	195B181   147	2403027008	RE20-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.23315	-118.34541	PC FOR ROOF MOUNTED PV SYSTEM ON SFD. SYSTEM SIZE 15.12KW ACSCOPE INCLUDES 42 AC MODULES WITH SOLAR PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54882	12041-20000-17707	140 N HOMEWOOD ROAD	90049	11	132B141   221	4403007006	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.05986	-118.47992	PV system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54883	19041-10000-04305	742 W GARDENA BLVD	90247	15	069B197   456	6121006047	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	33.88146	-118.28857	PLAN CHECK FOR FIRE ALARM SYSTEM CONSISTING OF 1 FIRE ALARM CONTROL PANEL AND 30 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54884	14041-10000-05498	333 S HOPE ST LEVEL D	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOMS FOR WELLS FARGO. HIGH RISE. LEVEL D BASEMENT. 570 SQFT.  ALL WORK TO BE INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54885	14041-20000-21079	12400 W WILSHIRE BLVD Stes 450-460	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM			Not Ready to Issue	08/05/2014 12:00:00 AM	ADDRESS	34.04157	-118.47031	Office TI under 2008 Title 24 in an (E) highrise office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54886	16041-30000-28614	2029 S CENTURY PARK EAST 23rd Floor-Restroom	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check Title 24 only in existing high-rise men and women restroom on 23rd floor. Total lighting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54887	18041-20000-02358	9336 W WAYSIDE DR	91040	7	207B185   522	2549017009	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Re-Activate Permit	07/10/2018 12:00:00 AM	ADDRESS	34.26102	-118.33471	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (35) modules. System is interconnecting with a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54888	13041-10000-34471	152 S SERRANO AVE	90004	10	138B193  1184	5517012011	R1-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.0722	-118.30656	PV1, Install a 10.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformered inverter(s)[FRONIUS # IG Plus V 10.0] and (42) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54889	19041-10000-21470	2905 W EXPOSITION PL	90018	10	117B185    13	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2342.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.02038	-118.3277	pc for fire sprinkler system. 1 FACP and 9 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54890	17041-10000-28565	1246 W 30TH ST	90007	9	120B197   346	5039001065	(Q)R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.02732	-118.29025	Replace existing fire alarm control panel to a new ones, all notification devices are existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54891	11041-20003-23488	8750 N SEPULVEDA BLVD	91343	6	195B145   409	2654012007	C2-1	North Valley	Mission Hills - Panorama City - North Hills			1175.20	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.22986	-118.46741	Changes to automatic lighting controls for approved plan under 11041-20001-23488.  No change to the installed lighting, oknly replace the LCP with intermatic ET90000 atuomatic time switch.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54892	11041-10000-10397	6060 W SUNSET BLVD	90028	13	147A189    57	5545013043	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	34.09786	-118.32167	T24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54893	18041-20000-27242	20203 W GERMAIN ST	91311	12	207B113   144	2707020008	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.26285	-118.57454	Plan check for a PV1 roof-mounted PV system. System size is 16.5 kWdc/15.4 kWac and consists of (2) 7.6 kWac rated inverters, (50) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54894	18041-10000-07456	6161 W PICO BLVD	90035	5	129B173    23	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.05339	-118.37556	PC for T24 only for replacement of indoor lighting to LED fixtures with LED driver for Chase bank. Egress lighting is not part of the scope. Total area Indoor  is 6170sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54895	13041-20000-23813	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Closed	01/15/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	PC FOR SIGN. T24 ENERGY ONLY. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54896	11041-20000-09681	11926 W ALLEGHENY ST	91352	6	198B169   140	2631003030	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	08/01/2011 12:00:00 AM	ADDRESS	34.23707	-118.39293	PLAN CHECK FOR NEW 600A SERVICE AND SWITCHBOARD. TO REPLACE EXISTING 200A SERVICE AND PANEL. NO NEW LOADS AND CKT WIRING ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54897	11041-10000-20621	1088-1092 E ELKGROVE AVE BLDG 23	90291	11	111B145   234	4243001038	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.00285	-118.45953	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54898	17041-10000-28676	1171 S SOTO ST	90023	14	121-5A221  29	5170006010	MR2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.02846	-118.21949	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY TOTAL SQ FT 6700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54899	13041-20000-14949	11601 W WILSHIRE BLVD 1ST FLOOR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	T24 FOR HIGHRISE OFFICE SPACE. SCOPE OF WORK LOCATED IN MAIN LOBBY (FIRST FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54900	15041-20001-32672	18852 W KILLOCH WAY	91326	12	216B121   169	2820015024	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.2912	-118.54413	Expedited per customer request.PV1. Install roof mounted PV system sized 7.5 kW. Interconnected with main service panel.(30) SolarWorld 280 Modules(30) Enphase Energy M250 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54901	18041-20000-43428	11541 W CANTON DR	91604	2	159B169   309	2377017003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Expired	06/09/2024 12:00:00 AM	ADDRESS	34.13308	-118.38501	PV1.  Install roof mounted PV system sized 10.7 kW AC interconnected with MSP.  (57) modules with 10 and 7.6 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54902	17041-20000-08635	15303 W VENTURA BLVD 9th Floor	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Issued	03/17/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	Plan check for Title 24 only. Project site is the 9th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,031 sq. ft.Note: Building permit has been issued under 17016-10000-04146	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54903	13041-10002-17467	8223 S FIGUEROA ST	90003	8	099B201  1336	6032021012	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Apartment			09/30/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	33.96368	-118.28297	RESTAMPING AN APPROVE SET. FEES PAID UNDER PERMIT# 13041--20000-17467 (((New 37 unit apartment building.  Full Plan Check.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54904	17041-10000-39906	7732 S STEWART AVE	90045	11	099B161   171	4112023021	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	33.96972	-118.41143	PC FOR POWER, SCOPE OF WORK INCLUDES THE ADDITION OF (2) TESLA BATTERIES TO AN EXISTING SOLAR SYSTEM AND THE ADDITION OF A LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54905	15041-10000-30844	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.04166	-118.26677	install  new fire alarm system for a new 34-story and 2 below ground parking levels building. total devices 3535 devices and one control panel and one fa panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54906	19041-20000-05451	24215 S STERLING RANCH ROAD	91304	12	192B089   182	2017038014	RE11-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.21965	-118.65458	Plan check for a PV1 roof-mounted PV system. System size is 2.83 kWdc/3 kWac and consists of (1) inverter and (9) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54907	16041-20000-33715	10862 N BONITA LANE	91345	7	207B149   114	2615022038	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.26761	-118.45537	Plan check for installation of pv system for SFD, roof-mounted. Interconnect with 200A MSP. 4.8kW ungrounded system. (15) 320W ac modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54908	17041-10000-30490	20929 W VENTURA BLVD 6,7,9,10	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Closed	09/26/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	TITLE 24 PLAN CHECK FOR - T.I. FOR EXISTING RETAIL (UNIT 6,7,9,10) INCLUDING: DEMO FLOORING AND SUSPENDED CEILING. ADD NEW PARTITION WALLS. NO CHANGE OF USE. NO FIXTURES - TOTAL AFFECTED AREA = 5300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54909	15041-20001-35651	19412 W MAYALL ST	91324	12	204B117   477	2726019024	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.25352	-118.55589	Epress Permit pulled under 15041-30000-35651. Inspector requested PC.(66) modules SUNIVA OPT 275-60-4-1B0, 280W(66) microinverters: ENPHASE M250-60-22L-S22-IG((ROOF MOUNTED GRID-TIED, STRING INVERTER SYSTEM.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54910	19041-10000-11314	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			PC Info Complete	05/02/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	PLAN CHECK FOR POWER AND ENERGY IN TERMINAL 2 OF LAX. PHASE 0S: ALTERATIONS TO TERMINAL 2 AIRSIDE EGRESS STAIRS, ASSOCIATED UPDATES TO THE MASTER FIRE LIFE SAFETY EXHIBITS. bUILDING PERMIT: 19016-10000-07540	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54911	14041-10000-34842	8560 W DAY ST	91040	7	204B189   938	2560035028	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.25415	-118.31992	Installation of new roof mounted solar PV array.  Total system size = 8 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54912	18041-10000-24814	3323-3333 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	09/29/2022 12:00:00 AM	ADDRESS	34.02738	-118.37232	Install new Fire Alarm System on New 910 unit mixed-use building. (4037) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54913	18041-10000-30202	19321 W VENTURA BLVD	91356	3	174B117   304	2163001018	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.17285	-118.5543	TI IN AN EXISTING BAKERY DUE TO FIRE DAMAGE. T-24 ENERGY ONLY. BLDG PERMIT: 18016-20000-20562NO CHANGE IN OCCUPANCY.NO NEW LOAD ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54914	11041-10000-13326	5907 N SHIRLEY AVE	91356	3	177B117   770	2153027008	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	01/06/2012 12:00:00 AM	ADDRESS	34.17757	-118.55805	NEW PV SYSTEM FOR A SINGLE FAMILY RESIDENCE.  OVER THE OCUNTER PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54915	14041-20000-03589	3183 W WILSHIRE BLVD 1st Floor	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			02/07/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.06196	-118.29111	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE FIRST FLOOR. all work to be indoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54916	19041-10000-42261	2121 S AVENUE OF THE STARS STE 2450	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM			PC Info Complete	10/17/2019 12:00:00 AM	ADDRESS	34.05554	-118.41342	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 3774 SFQT. B#19016-40000-30013	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54917	16041-10000-39524	11025 W WEDDINGTON ST	91601	2	171B173   258	2350014007	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.16709	-118.37106	PC FOR ENERGY, T24 ONLY. RELOCATION AND CHANGE OF FROM SINGLE FAMILY HOUSE TO A RECREATION FACILITY.  LOAD < 400A. TOTAL AREA 1361 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54918	18041-20000-44149	2490 N CHEREMOYA AVE	90068	4	154-5A189 484	5580005016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Apartment			11/19/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Issued	12/18/2018 12:00:00 AM	ADDRESS	34.11577	-118.32088	PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 6 MODULES (SW 325 XL MONO) AND 6  MICROINVERTERS.  SYSTEM SIZE IS 1.95 KWdc and 1.68 KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54919	13041-10000-35221	4700 W WESTERN HERITAGE WAY	90027	4	162B201     5	5593002***	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.14865	-118.28197	Plan check for power and energy. T24 2008 standards. Tenant imrovement for Autry museum. Utilizing existing panels. No new distribution equipment. 1st extension filed on 6/29/2015 to extend to 12/30/2015.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54920	16041-10000-05628	12636 W MATTESON AVE	90066	11	111B153   823	4235004009	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Apartment			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	33.99965	-118.43637	NEW FIRE ALARM SYSTEM TO A 30 UNIT APARTMENT. (1) FIRE ALARM PANEL, (85) FIRE ALARM DEVICES AND (1) COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54921	19041-20000-52091	10045 N VANALDEN AVE	91324	12	204B121   500	2729026018	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	34.25285	-118.54935	PV1. INSTALL 11.34 KW DC/10.34 KW CEC AC PV SYSTEM WITH (36) MODULES, OPTIMIZERS AND (1) INVERTER(SE1000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54922	17041-10000-44218	1650 S WESTMORELAND BLVD	90006	10	126B193   367	5074018004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.04303	-118.30641	PC FOR ROOFMOUNTED PV ON SFD WITH ESS SYSTEM INSTALLED (UNDER SUPP. APPLICATION).SYSTEM SIZE 3.0KWAC ADN 4.4KWDC SCOPE INCLUDES 11 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54923	16041-10002-42324	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Info Complete	05/11/2017 12:00:00 AM	ADDRESS	34.24138	-118.60168	PC FOR TITLE -24 ENERGY ONLY.CHANGES TO APPROVE SET PER INSPECTION TO REFLECT NEW FIXTURE INSTALLED. TOTAL AREA HAS INCREASED TO 17883 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54924	18041-10000-23424	5220 W CENTINELA AVE	90045	11	102B173    95	4103002016	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	33.97718	-118.37106	Energy plan check for a restaurant T.I. Scope includes new lighting and equipment with a total Title-24 area cover 1,894-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54925	18041-20000-17446	3333 E MISSION ROAD	90031	1	136-5A225 304	5211004019	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	PIN	34.06677133	-118.20531249	$0.00 fee due to senate bill 12222 and lb1414Plan check for PV roof mounted system on commercial building, system size: 32.48kWac with 141 modules and 141 microinverters connected to 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54926	17041-20000-08270	22785 W CHARLEMONT PL	91364	3	165B097   433	2078004032	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Issued	04/26/2017 12:00:00 AM	ADDRESS	34.14775	-118.62358	"""0$ permit fees due to senate billl 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54927	14041-20001-27682	5334 N OVERING DR	91367	3	171B089   136	2047018016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM			PC Approved	11/19/2014 12:00:00 AM	ADDRESS	34.16722	-118.64765	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 12kW.(2) Aurora PVI-6000TL-OUTD-S-US-A transformerless inverters(40) Sun Power SPR-E20-327 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54928	14041-20001-12488	19120 W ERWIN ST	91335	3	177B121   244	2128024015	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.1839	-118.54922	expedite per customer request.pv1 install roof mounted pv system sized 4.5kw interconnected with main panel.  (1) transformerless inverter model #solaredge se500A with power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54929	14041-20000-11498	11601 W WILSHIRE BLVD SUITE 500	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	pc for t24 energy only. existing office remodel. new lighting. WORK DONE IN SUITE 500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54930	16041-10000-35656	1267 N LAKME AVE	90744	15	033B209   150	7422007020	R1-1XL-O-HPOZ-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	33.78874	-118.26019	PV1. Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6.0kWac.  Central inverter system with 28 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54931	10041-20000-20669	6600 N TOPANGA CANYON BLVD #1044	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	10/18/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	energy plan check # 1044	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54932	15041-20000-37172	1107 N BRONSON AVE	90038	13	144B189   644	5534010009	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.09102	-118.31808	Plan check for power and lighting. Project site is an existing commercial building (rock-climbing gym). Building occupancy is A3 with an occupant load of 246. Project scope is a tenant improvement. Total lighting area = 20,590 sq. ft.Note: Building permit has been issued under 14016-10000-21613	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54933	16041-10000-18570	6201 W HOLLYWOOD BLVD 104	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	RESTAURANT TI. PC FOR T24 ENERGY ONLY FOR NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54934	18041-20000-43965	5750 W WILSHIRE BLVD ste 640-645	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.06227	-118.3542	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54935	12041-20000-01412	9636-9660 N COZYCROFT AVE	91311	12	201B109   243	2748003088	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	02/29/2012 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	ADDRESS	34.24548	-118.58185	FIRE DAMAGE REPAIR OF WAREHOUSE;  INSTALL NEW 800A SERVICE, NEW PANELS.  INSTALL NEW LIGHTS FOR SPACES 9654, 9656, 9560.  REPLACE SUBPANELS FOR SPACES 9636 AND 9642.  ALL EXISTING BRANCH CIRCUITS FOR SPACES 9636 AND 9642  RELOCATE TO REPLACEMENT SUBPANELS.  NO NEW LIGHTING INSTALL IN SPACES 9636 AND 9642.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54936	17041-10001-20195	14040 W FOOTHILL BLVD	91342	7	225B153   250	2504019049	R3-1-CPIO	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.31435	-118.43968	MODULES WERE REPLACED AS MANUFACTURER FOR ORIGINAL MODULES WENT OUT OF BUSINESS. PV SYSTEM ( 355 MODULES 56.695KW AC) WAS ADJUSTED FOR THIS CHANGE OF MODULES(((((((PC FOR PV SYSTEM CONNTECTED TO EXISTING MAIN PANEL. THIS IS COMMERCIAL PV. THIS SYSTEM USES 6 INVERTERs, TOTAL RATED 56.695KW AC. THIS SYSTEM NET METERS METER # PMS222-11509. THIS IS SYSTEM 1/3 ON SAME ROOF. SYSTEM USES POWER OPTIMIZERS. Note: Permit fees are $0 due to senate bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54937	11041-10000-24535	668 S BONNIE BRAE ST	90057	1	132A205   150	5142007015	C2-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM			PC Approved	01/05/2012 12:00:00 AM	ADDRESS	34.05622	-118.27383	T.I. to an existing office building.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54938	19041-10000-21462	18028 W HORACE ST	91344	12	210B125   564	2715022067	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Issued	06/18/2019 12:00:00 AM	ADDRESS	34.26996	-118.52669	(ePlan) PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.095KWdc / 10.60KWac CONSISTING OF 2 INVERTERS(SE7600H-US & SE3000H-US) WITH 41 MODULES USING P320 OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54939	16041-10000-37707	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR T24 REVISION OF ROOF LIGHTING FOR DINING AREAS AND STORAGE SPACES.. MINOR REVISIONS TO INTERIOR BATHROOMS. TOTAL AFFECTED AREA IS 22,000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54940	14041-10004-18948	2590 E ARVIA ST	90065	1	144A217   404	5445006907	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.09482	-118.23131	12/02/2016 Changes to an approved set of plans. Changes include add additional circuits receptacle in DAS room and MSO Circuit. Changes apply to delta 7 only. {{{{{{New 108 unit apartment and future commercial. Plan check for power and energy. 5 typical units. No methane for applicant. Plan checker to verify fees. Applicant will bring a new set of plans designed for the old 2010 energy code. Fire alarm variance has been filed already.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54941	18041-20001-34978	12301 W WILSHIRE BLVD ste 405	90025	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.04271	-118.46948	2/21/2019changes to an approved set of plans.  changes to provide fusible disconnect switch to existing bus bar.this is plan check only.  ((((ti to an existing commercial building (Dental Office).  adding new lighting new controls to a new panel, plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54942	10041-10000-09381	120 N ROBERTSON BLVD 201 & 202	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	06/25/2010 12:00:00 AM	ADDRESS	34.07585	-118.38356	INTERIOR TENANT IMPROVEMENT ON SECOND FLOOR IN EXISTING BUILDING. PROJECT INCLUDES NEW PARTITIONS, NEW MILLWORK, AND NEW CEILINGS. IN OFFICE AREAS.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54943	15041-20000-12960	2590 E ARVIA ST	90031	1	145-5A217 505	5445006907	[Q]CM-1-CDO-RIO, [Q]PF-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			04/30/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	PIN	34.09366281	-118.23090869	Plan check for 4-Story Appartmet fire alarm system. Total device: 268 and 1 fire alarm panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54944	18041-20000-25698	8708-8722 N SUNLAND BLVD	91352	6	195B177   525	2404026082	(Q)C2-1VL-CUGU, C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.01	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	08/11/2020 12:00:00 AM	ADDRESS	34.22791	-118.36595	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor canopy lighting. Total lighting area = 2,010 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54945	12041-10000-19237	12938 W AETNA ST	91401	2	177B161   804	2331023019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.18019	-118.41531	PLAN CHECK 1.17KW ROOF MOUNTED PHOTOVOLTAIC (GROWATT TRANSFORMLESS INVERTER) SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54946	14041-10000-17416	523 W 6TH ST Suite 1220	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Expired	08/04/2016 12:00:00 AM	PIN	34.04872199	-118.25441618	Title 24 plan check only.  Total area = 775 sq. ft.Install new lighting in existing commercial space.  No changes tto power equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54947	17041-10000-27810	1130 W SLAUSON AVE	90044	9	108B197  1495	6003003044	P-1, [Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	33.98887	-118.29488	REMOVE HIS FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY. TOTAL SQUARE FT 3375.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54948	16041-10000-21983	2148 E SANTA ANA BLVD NORT	90059	15	088-5A217 726	6067028034		South Los Angeles				2430.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	PIN	33.93575566	-118.23375765	PV1, rooftop solar installation on SFD, 4kW AC system   (16) CS6P-250P     (16) Enphase M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54949	16041-20001-18213	6600 N TOPANGA CANYON BLVD space 68	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Expired	10/18/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	09/06/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. Indicated home-runs have been modified or added.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY PER APPLICANT. Tenant improvment of (e) retail space.building permit #16016-20000-11972	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54950	16041-10000-27658	405 S MATEO ST	90013	14	127-5A217  62	5163018006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.04184	-118.23305	PC FOR POWER AND ENERGY. CORE&SHELL RENOVATION OF EXISTING BLDGS, NO TENANT IMPROVEMENT IS INCLUDED AS PART OF SCOPE. SERVICE 4000A, 480/277 3 PHASE AND 4W. TOTAL AREA 5919 SQ FT.B#  16016-10000-17710	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54951	16041-20000-19305	8912 N SEPULVEDA BLVD	91343	7	195B145   238	2654005038	M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.23227	-118.46736	Plan check for power and energy for service upgrade new 1,200A service  in existing wearhouse. Total area:16,830  sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54952	14041-10000-01898	19824 W FALCON CREST CT	91326	12	217-5A117 245	2701018032	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.29041	-118.56514	PV1 7.74KWdc. 240V. microinverter. NONstd. 2story. Roofmount. [(36) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(36)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54953	16041-10001-45023	3280 S MOTOR AVE	90034	5	123B161   963	4314024020	M1-1	West Los Angeles	West Los Angeles			2699.07	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM			PC Info Complete	09/06/2017 12:00:00 AM	ADDRESS	34.02969	-118.41085	CHANGES TO APPROVED SET OF PLANS. CHANGE TO DISTRIBUTION SYSTEM. RELOCATED ALL FEEDERS TO RUN FROM MAIN SWITCHBOARD. REPLACED AN EXISTING PANEL, ADDDED OUTDOOR LIGHTING AND T24. ALL CHANGES UNDER DELTA-1 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54954	13041-10000-36000	1209-1215 S BEDFORD ST	90035	5	132B169   835	4332019033	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			12/26/2013 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.05537	-118.38074	PLANCHECK FOR POWER AND ENERGY. NEW 21 UNIT APARTMENT BLDG. 5 STORIES. Fire alarm variance filed 10/28/2014.BLDG PC: 13010-30000-02593	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54955	19041-10000-05462	4340 W LOCKWOOD AVE	90029	13	144B197  1146	5539008032	RD1.5-1XL	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.08859	-118.2882	Energy plan check for a kitchen lighting replacement in the same location of a commercial building. Total area is 549-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54956	12041-10000-09216	2560 W OLYMPIC BLVD # 101	90006	1	130-5A201 141	5076008028	(Q)C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.05219	-118.28707	CHANGE OF USE FROM OFFICES TO MASSAGE/BEAUTY  SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54957	17041-10000-38256	18226 W VENTURA BLVD	91356	3	171B125   309	2181010028	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.16616	-118.52995	replaCe  indoor stairwell luminaires and outdoor HID lumInaIres with LED TYPESPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54958	10041-10000-21036	2500 S NAVY WAY BLDG 200	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	11/01/2010 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	33.73363	-118.2408	T-24 LIGHTING PLAN CHECK- ONLY- FOR ALTERATION TO EXISTING LIGHTING SYSTEM.  TI-BUILD NEW PARTITION WALLS TO CREATE OFFICE SPACES. REPAIR CEILING AS NECESSARY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54959	15041-10000-02465	350 S GRAND AVE Suite 3950	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Issued	02/05/2015 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for Title 24 only. Project is a TI for a single suite in a high-rise building (Suite 3950 on the 39th floor) Total lighting area = 6,250 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54960	15041-20001-31202	5107 N GAVIOTA AVE	91436	5	171B141   393	2261025010	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.16234	-118.48164	Expedited per customer request.PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service panel. (47) Hanwha BLK-G3 270W Modules(1) Solar Edge TL SE10000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54961	15041-10000-31221	1245 S LA BREA AVE	90019	10	129B181   260	5084028008	C2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.05216	-118.34429	T-24, TI TO AN (E) COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 915. PC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54962	18041-20001-40063	3333 S BARBYDELL DR	90064	5	123B165   782	4316024019	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.03228	-118.40384		N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54963	14041-20000-15452	6705 N FALLBROOK AVE	91307	12	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.19106	-118.62366	PLAN CHECK FOR ENERGY ONLY T-24 (EXTERIOR) FOR AN EXISTING HOMETOWN BUFFET.2110 LINEAR FEET FOR OUTSIDE PERIMETER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54964	19041-20000-09204	240 N ROCKINGHAM AVE	90049	11	132B137   204	4406008001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	06/10/2022 12:00:00 AM	ADDRESS	34.05974	-118.49126	PV1.  Install 11.7 kW DC / 9.36 kW AC roof mounted grid tied PV system.  (39) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54965	15041-10000-39459	4151 W PROSPECT AVE LOWER LV	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Issued	12/01/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	T-24, TI TO AN OFFICE SPACE, TOTAL SQ. FT. 4226. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54966	17041-10000-15391	1310 N GORDON ST	90028	13	144B189    39	5545014030	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			06/09/2017 12:00:00 AM			PC Info Complete	07/25/2018 12:00:00 AM	ADDRESS	34.09478	-118.31997	NEW 21 UNIT FOUR STORY APARTMENT WITH SUBTERRANEAN PARKING. PC FOR POWER AND ENERGY. Building # 16010-10000-05916.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54967	16041-20000-36535	1001 E VERNON AVE	90011	9	112-5A209  16	5115014019	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.00408	-118.25812	Plan check for a fire alarm system for a single-story commercial building. System consists of (1) FACP, (1) annunciator, and (22) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54968	17041-20000-19454	11938 W PICO BLVD	90064	11	123B149  1015	4259039012	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.02973	-118.4491	Tenant improvement of (E) restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54969	13041-20000-18428	920 W STATLER ST	90731	15	024B197    33	7442003040	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	08/08/2013 12:00:00 AM	ADDRESS	33.76416	-118.29831	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW. USING 28 MODULES ENPHASE MICROINVERTER M215. PV STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54970	14041-20001-19186	18050 W PARTHENIA ST	91325	12	195B125   856	2787001024	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM			PC Approved	08/08/2014 12:00:00 AM	ADDRESS	34.22851	-118.52649	Modification to approved set.  Proposed buried conduit from detached garage array to main house to run alongside existing gutter spanning garage to main house.   (((5KW PV1 roof-mounted system with (1) SolarEdge SE5000A-US inverter, (18) Trina Solar TSM 255P and SolarEdge P300 Power Optimizers.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54971	18041-20000-48226	8619 N NORWICH AVE pv1	91343	6	195B145   618	2653010070	R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.22696	-118.46041	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54972	19041-20000-49851	14261 W JUDD ST	91331	6	204B153   619	2647020036	RS-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.25445	-118.44409	PV1.  Install 11.220 kW roof mounted PV system.  (34) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54973	13041-10000-33486	4501 W COLORADO BLVD B8 MNTANCE-SHOP	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	TITLE 24 PART 6 TO EXISTING BUILDING; TI TO BUILDING MAINTENANCE SHOP IN BASEMENT; LIGHTING ALTERATION TO AN PROJECTED AREA OF 793 SQ FT.. SCOPE OF WORK < 400A. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54974	10041-10000-17531	558 S BROADWAY	90013	14	129A211   167	5149035011	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	09/03/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	34.04675	-118.25174	T24 energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54975	15041-10000-04917	11952 N DUNNICLIFFE CT	91326	12	216B125   135	2870021020	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.28898	-118.53758	PV1.  Installation of new roof mounted solar PV array.  Total system size = 8.64 kWac (microinverter)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54976	13041-10000-00060	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/02/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	290.5KW  PV SYSTEM  INSTALLED ON THE ROOFS  3 BUILDINGS AT SHOPPING MALL OF MODULE - HANWHA HSL60P6-PA-0-250K, INVERTER - SOLECTRIA SGI 500-480. WITH  INTERNAL TRANSFORMER;  1162 MODULES, 83 STRINGS, AND 4 COMBINER BOXES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54977	17041-10000-08562	6111 N TOPANGA CANYON BLVD #4	91367	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM			Verifications in Progress	05/22/2017 12:00:00 AM	ADDRESS	34.18157	-118.60615	PC for Power only. Replacing existing service with new Temporary switchboard service that is being installed for car dealership use.  New Switchboard is rated at 600 amps 277/480 V 3phase 4wire. Existing load is being rewired, and also adding new load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54978	10041-10001-25267	733 N NEW HIGH ST # C	90012	1	133-5A215  77	5408023004	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM			PC Approved	01/14/2011 12:00:00 AM	ADDRESS	34.06106	-118.23828	ADDING PANEL AND CIRCUITS IN BEAUTY SALONPLAN CHK IS FOR TITLE 24  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54979	19041-20001-38830	18735 W LISBURN PL	91326	12	219B121   169	2870002012	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	34.29516	-118.54203	EXPEDITED PER CUSTOMER REQUESTPV1. INSTALL 11.34 KW AC PV SYSTEM WITH (36) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE10000H). SCOPE OF WORK INCLUDES (3) NEW TESLA ENERGY STORAGE BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54980	19041-10000-26933	3912 S GRAND AVE	90037	9	117A203   277	5122046028	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	34.01322	-118.28039	PC FOR POWER ONLY. SCOPE INCLUDES A NEW 300KW TEMPORARY GENERATOR. TEMPORARY POWER FOR A FREE STANDING SIGN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54981	12041-20000-01841	12541 W BEATRICE ST	90066	11	105B161   940	4211006026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Expired	07/29/2014 12:00:00 AM	ADDRESS	33.98116	-118.41478	PROPOSE TO CREATE A KITCHEN, 450 S.F. TO AN EXISTING BUSINESS BLDG. ON LEVEL 1.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54982	18041-20000-43440	2415 N GREEN VIEW PL	90046	4	153B169   248	5564033020	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.11635	-118.38911	Installation of 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54983	14041-10002-30539	837 E 4TH PL	90013	14	127-5A215 207	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.04401	-118.23553	PC FOR TITLE 24 FOR  A NEW EMC( ELECTRONIC MESSAGE CENTER).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54984	14041-20000-13867	1638 S HIGHLAND AVE	90019	10	126B181   172	5067006011	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.04482	-118.34448	Roof mounted PV system with transformerless inverter.  PV system size 7.1KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54985	19041-20001-50126	4830 N NOMAD DR	91364	3	168B113   145	2175017003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.15889	-118.56786	PV1. INSTALL 8.06 KW DC PV SYSTEM WITH (138) TESLA TILE MODULES (2) INVERTERS, AND (2) ENERGY STORAGE BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54986	17041-20001-32172	10701 W LONGFORD ST	91342	7	213B177   137	2529016014	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.27793	-118.36355	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.67 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54987	14041-20000-06148	12180 W MILLENNIUM	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			Corrections Issued	03/06/2014 12:00:00 AM	ADDRESS	33.97975	-118.40731	T24 FOR EXISTING OFFICE BUIDLGIN OUTDOOR AND SOME INDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54988	18041-10000-19484	1835 W 88TH ST	90047	8	096A193    36	6036011007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	33.95827	-118.31038	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 6.82KWDC/ 7.6KWDCSCOPE INCLUDES 22 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER. NOTE: USING  A SOLAR READY PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
54989	16041-10000-30843	6200 W HOLLYWOOD BLVD	90028	13	148-5A189 130	5546028002	[T][Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.10136	-118.32459	Installation of fire alarm system in new 7 story low-rise mixed use apartment building.  Total system size = 3,180 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54990	16041-10000-32907	13050 W SAN VICENTE BLVD #101	90049	11	129B137   501	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.0483	-118.49125	Plan Check for T-24 only.  TI on (E) retail space. Install new lightings and receptacles, new 200A panel. Total affected area: 1,495 sq.ft((B# 16016-10000-21242))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54991	18041-20000-23507	611 N FAIRFAX AVE	90036	5	141B177   859	5527017012	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.08204	-118.36164	Plan check for Title 24 Energy only T.I. existing space. Total area: 1290 sq ft.B#18016-10000-10381	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54992	19041-10001-04467	17720 W FULLERFARM ST	91325	12	204B129   388	2734005020	RA-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM			PC Approved	04/04/2019 12:00:00 AM	ADDRESS	34.25388	-118.52071	SUPPLEMENTAL CHANGES TO APPROVED SET AIC RATING OF METER TO 10KAIC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54993	19041-10000-14627	1050 W ARROYO ST	91340	7	216B161   160	2514019014	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	05/15/2020 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	PIN	34.2881352	-118.41898074	POWER PLAN CHECK FOR NEW 800A 277/480V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD. Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters back feed to the distribution panel with the application # 19041-10000-14636	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
54994	14041-20000-12193	5553 W SUNSET BLVD	90028	13	147A193    94	5544023024	[Q]C2-2D	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.09826	-118.31121	Chnage of use from retail to pizza restaurant.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54995	18041-10000-08501	1700 S SANTA FE AVE 1st floor-# 101	90021	14	120A217    21	5168001004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.02438	-118.22983	first tenant in commercial office spacefull plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54996	19041-10000-26386	9027 N CANOGA AVE Suite - L	91304	3	195B105    39	2779018039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.23429	-118.59779	Remove HID fixtures and replace with new LED fixtures (Indoor Only) Suite #L - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54997	17041-10000-23761	1626 S LONG BEACH AVE	90021	14	120A213   271	5167002038	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Issued	08/28/2017 12:00:00 AM	ADDRESS	34.02242	-118.24254	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING ROOF-TOP. TOTAL SYSTEM SYSTEM SIZE IS 16.8 KWdc / 15.0 KWac.(42) MODULES-SOLARBINE SB-M380NA1 & SB-S410SA1(1)INVERTER-STL15000TL-US(1)TRANFORMER-15KVA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
54998	12041-10001-06138	116 N ROBERTSON BLVD #900	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	34.0758	-118.38356	PLAN CHECK REVISION TO T24 ENERGY APPROVED PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
54999	12041-10000-30636	5165 W FOUNTAIN AVE	90027	13	147A195   255	5544038018	R3-1, RD1.5-1XL	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Expired	09/15/2015 12:00:00 AM	PIN	34.09560111	-118.30193166	Church of Scientology.  Existing 4 story building plus basement.  Complete remodel of the interior with service upgrade.  Building is to be converted to dormitory with 197 guest rooms.  Fire alarm plans are included.  Plans were previously plan checked and approved under 10041-10000-01486.  Applicant says that the electrical design has changed and the load has increased and is therfore submitting for a new plan check.  At time of submittal, aplicant will include the previously approved set of plans.  vARIANCE SUBMITTED FOR FIRE ALARM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55000	19041-10000-05239	639-659 S BROADWAY	90014	14	129A211   230	5144003040	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.04587	-118.25309	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW OUTDOOR LIGHTS FOR EXISTING COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55001	18041-10000-27606	5340 W 102ND ST	90045	11	090B173   206	4129032007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.9435	-118.37386	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55002	17041-10000-26064	843 N VIA DE LA PAZ	90272	11	129B125   735	4412004022	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.04604	-118.52755	Plan check for Title 24 only indoor ATM room and outdoor area. Total area: 347 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55003	19041-20000-42944	9016 W HOPEN PL	90069	4	147B169   507	5561010009	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.09914	-118.38712	Plan check only, plan check for power only, scope of work consists of new 1200A service, 1200A MDP, (10) subpanels, (2) 3.1-5 HP-KVA equipments, (11) 5.1-20 HP-KVA equipments, (1) 20.1-50 HP-KVA equipments, and (169) branch circuitspermit paid under building combo permit #18010-30000-01620	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55004	17041-10000-23286	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Info Complete	07/11/2017 12:00:00 AM	ADDRESS	34.27455	-118.56289	ADDITION OF STORAGE ROOM. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55005	16041-10000-18612	725 S FIGUEROA ST STE 2050	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR ENERGY. TI WORK ON 3100 SQ FT OF TOTAL FLOOR AREA; NEW WALL, POWER, LIGHTING AND FINISHES; SCOPE OF T24 3123 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55006	18041-10000-19009	15350 W NORDHOFF ST B	91343	7	195B145   652	2654004050	[Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.23519	-118.46701	PC FOR RETAIL TI IN T-MOBILE STORE FOR TITLE 24  ENERGY ONLY!SCOPE INCLUDES NEW PANEL, LIGHTS AND EQUIPMENT.TOTAL AFFECTECD AREA 1910 SQ. FT. B# 18016-10000-15350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55007	12041-10000-00674	16530 W HIAWATHA ST	91344	12	204B137    79	2679023002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2012 12:00:00 AM	01/30/2012 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.25947	-118.49198	New 4.2 kw roof mounted photovoltaic system for an existing single family residence.  Enphase M215 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55008	11041-20000-07827	16000 W VENTURA BLVD #500	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	34.15584	-118.48164	T.I. to a high rise building.  Install general/emergency lighting of 5th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55009	04041-30006-31759	1925 W WILSHIRE BLVD	90057	1	132A203    23	5142001022	C4-2	Central	Westlake		YES	2089.02	Electrical	Electrical	Commercial			09/30/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	34.0574	-118.27431	REVISIONS ( DELTA C)TO PERMITTED SET OF PLANS-ADDED LUMINAIRES; NEW CIRCUITSRENOVATION FOR THE LA OPEN DOOR PRESBYTERIAN  CHURCHREVISIONS TO APPROVED SET OF PLANS-CU FEEDERS HAVE BEEN CHANGED TO AL FEEDERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55010	10041-10000-20900	13455 W MAXELLA AVE Unit # 270	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM			Corrections Issued	11/01/2010 12:00:00 AM	ADDRESS	33.9867	-118.44159	"Install a new Fire Alarm System in an existing ""AMC Marina 6"" Theatre building.  <<<<Power and energy submitted under 10041-10000-20893>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55011	16041-10001-34971	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.06086	-118.27891	1ST CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DETLA 1 ON PLANS. CHANGE TO ELEVATOR FEEDER TO NOW INCLUDE A TRANSFORMER TO FEED THE CONTROLLER. ALSO REVISED FLOOR PLAN TO TAKE SOME LIGHTING TO ROUTE TO EMERGENCYT PANEL. ADDED 3 EMERGENCY PANELS AND REVISED LOADS. UPDATED T24. NEW EQUIPMENTS UNDER THIS SCOPE HAVE BEEN INCLUDED UNDER MASTER PERMIT #16041-10000-34971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55012	18041-10001-33838	11018 N BAIRD AVE	91326	12	210B125   521	2717014012	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			PC Approved	09/18/2018 12:00:00 AM	ADDRESS	34.27034	-118.53708	PLAN CHECK FOR ROOF MONTED PV SYSTEM USING 32 AC MODULES (SUNPOWER SPR-X22-360-D-AC). SYSTEM SIZE 10.273 WITH MONITORING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55013	19041-10000-12870	5151 S VERMONT AVE	90037	9	108B197    75	5002030017	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices		2323.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	33.9958	-118.29167	PLAN CHECK FOR POWER UPGRADING 600 A SERVICE. NO NEW LOADS ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55014	19041-10000-22519	550 S HOPE ST # 430	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55015	10041-10000-10869	1829 S WESTERN AVE	90019	10	126B193   747	5073013006	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Expired	11/19/2012 12:00:00 AM	PIN	34.04092388	-118.30934236	New PV system for a church.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55016	14041-10000-29849	1655 N SERRANO AVE 1-40	90027	13	148-5A193 139	5544021029	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			10/28/2014 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.1014	-118.30734	New 5-story apartment building including (40) units for mix-use purposes of commercial and apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55017	15041-20000-17139	21650 W OXNARD ST 2300	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only remodel existing commercial office, new lights and exiting circuit. Total area: 1827 SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55018	19041-20000-37226	22540 W JEFFREY MARK CT #2	91311	12	204B097    15	2724004***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.2564	-118.61793	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 8.88 KW DC/7.6 KW AC. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH OPTIMIZERS AND 7.6 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55019	16041-20000-41202	563 N HOOVER ST	90004	13	141A201   145	5539028004	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Apartment			11/22/2016 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.08125	-118.28469	Plan check for power and energy. New 4 story, 9 unit apartment building - 3 typ units. 3 stories residential over 1st floor parking. 600A service. T24 area: indoor-6,875sqft; outdoor-1,750sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55020	11041-20000-08195	21044 W SHERMAN WAY	91303	3	183B105   227	2112030002	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	ADDRESS	34.20085	-118.59206	energy plan check sign	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55021	16041-10001-31140	10250 W SANTA MONICA BLVD # 1903	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"((""Johnny Was"" Ste. 1903)) Changes to approved set noted under Delta 3 and Delta 4: Revise lighting plan and T24 and power plan, demand load remain the same. Permit is under the master: 16041-10000-31140"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55022	13041-10000-29801			1	123A203   152	5124028004	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			Corrections Issued	10/24/2013 12:00:00 AM	PIN	34.03110835	-118.27546499	TITLE-24 PART 6 ENERGY FOR A CHARTER SCHOOL. SCOPE IS < 400A . TOTAL ILLUMINATED AREA TO BE 2170 SQ FT. EXISTING PERMIT FOR (1) OUTLET IS UNDER 13041-10000-26994. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.TO COMPLY W/ DEPT. ORDER DATED 09-11-06.  PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55023	19041-10000-51264	11228 N ALTA AVE Lot 12	91345	7	210B145   525	2664007***	P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.27442	-118.46892	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 9 MODULES (HANWHA Q.PEAK BLK-G5315), 9 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)SYSTEM SIZE: 2.835 KW DC;  3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55024	18041-20000-16425	14907 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29426	-118.45539	pv1install roof mounted pv system 3.8kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55025	18041-20001-30381	19520 W NORDHOFF ST #4	91324	12	195B117    12	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.23378	-118.55808	2/6/2019changes to an approved set of plans.  chamges to reflect field conditions.  this is plan check only.  ((((ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor lighting only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55026	13041-10000-06114	4627 N ARRIBA DR	91356	3	168B121   385	2176024012	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.15517	-118.54265	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.1 KW. USING STANDARD PLAN. 44 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55027	14041-20000-35757	4827 N FULTON AVE Bld. 5E	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.15858	-118.42347	New 3 story apartment with 24 units and 2 level subterranean garage.  New 1600A service, panels, branch circuits, and lighting.  Plan check for power and energy.Note: variance to separate fire alarm plans submitted on 12/29/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55028	11041-20000-27716	11001 N SEPULVEDA BLVD	91345	7	210B145   300	2664012031	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1093.00	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM	05/09/2013 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.2697	-118.4673	ADDITION OF NEW 25 HP elevator and elevator lobby	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55029	19041-20000-34853	12639 N GLENOAKS BLVD	91342	7	219B153    17	2508027013	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	12/01/2020 12:00:00 AM		Issued	12/01/2020 12:00:00 AM	ADDRESS	34.29974	-118.43991	FULL PLAN CHECK. SCOPE OF WORK INCLUDES NEW 1000A SERVICE, 3 SUB PANELS WITH LOADS, AND T24 FOR OUTDOOR LIGHTING. TOTAL OUTDOOR SQUARE FOOTAGE = 27680 SFB#19010-20000-03870	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55030	16041-10000-43485	5100-5102 E YORK BLVD	90042	14	156A225   348	5478006014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.12084	-118.20463	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM (E) BAKERY TO RESTAURANT. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLE FOR BAKERY/RESTAURANT. TOTAL AFFECTED AREA IS 2018 SQ. FT.  B#16016-10000-29374	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55031	19041-20000-40128	6367 N VAN NUYS BLVD	91401	6	180B149   936	2241004003	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.18626	-118.44902	T24 PLAN CHECK FOR TI REMODEL OFFICE SPACE. LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 2842 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55032	15041-20000-42329	14832 W HESBY ST	91403	4	171A149   243	2263030031	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.162	-118.45636	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.0KWac/13.407KWdc.(41) MODULE-SUNPOWER SPR-327NE-WHT-D(2)INVERTER-SUNNYBOY SMA SB6000TL-US AND SMA SB70000TL-USNote: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55033	19041-10000-12221	1833 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Issued	05/29/2019 12:00:00 AM	ADDRESS	34.04342	-118.37677	FULL PLAN CHECK FOR POWER AND ENERGY FOR RETAIL T.I. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING DISTRIBUTION SYSTEM. TOTAL EFFECTED AREA 9173 SQFT NEW CONNECTED LOAD OVER 400AMPSLD# 19016-10000-09627	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55034	12041-10000-11620	770 W WILSHIRE BLVD 4th FLOOR	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	34.04914	-118.25811	RETROFITTING EXISTING  130  2X4 FIXTURES WITH LED RETROFIT KIT ON 7 th FLOOR OF 9 FLOOR BUILDING.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55035	13041-20000-01304	4011 W JEFFERSON BLVD	90016	10	120B185   826	5050027060	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			PC Approved	01/17/2013 12:00:00 AM	ADDRESS	34.0257	-118.33977	Plan check for energy and emergency lighting. 2524 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55036	18041-10000-16472	5427 N SATSUMA AVE	91601	2	174B173  1346	2416012027	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Issued	05/04/2018 12:00:00 AM	ADDRESS	34.16944	-118.36764	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55037	18041-20000-32340	11840 W FOOTHILL BLVD UNIT E	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			Reviewed by Supervisor	08/29/2018 12:00:00 AM	ADDRESS	34.27347	-118.39434	Plan check for First Time Tenant space for a restaurant with existing lighting existing panel, new circuits and outlets. B#18016-20000-27332	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55038	15041-20000-08946	1000 W WILSHIRE BLVD 19th Floor	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for Title 24 only. Project scope is a tenant improvement to the 19th floor of an existing high-rise building. Total lighting area = 21,680 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55039	18041-10000-23897	6555 W BARTON AVE STE 500	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.08785	-118.33475	PC FOR ENERGY ONLY. INTERIOR TENANT IMPROVEMENT TO PORTION OF EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTLA AFFECTED AREA IS 655 SQ. FT. B#18016-10000-15699	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55040	12041-10000-11003	726 N ENCHANTED WAY	90272	11	129B121   516	4419012032	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.04907	-118.54915	New photovoltaic 7.59kw rooftop system for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55041	19041-20001-46966	6610 N ENSIGN AVE	91606	2	180B173   463	2319019022	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.19057	-118.37163	Expedite fee.PV1.  Install 11.02 kW DC / 8.8 kW AC roof mounted grid tied PV system.  (38) modules with 5.0 kW and 3.8 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55042	14041-20000-02657	5201 S FIGUEROA ST	90037	9	108B201   103	5001029001	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	33.99562	-118.28298	PLAN CHECK FOR POWER AND ENERGY. REPLACING EXISTING 600A SERVICE EQUIPMENT WITH NEW 600A SERVICE EQUIPMENT ALONG WITH NEW PANELS FOR NEW TENANTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55043	13041-10000-35199	735 E 12TH ST STE #112	90021	14	124-5A211 353	5132011241	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.03328	-118.25222	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 504 SQ FT. REPLACING TOTAL OF 2 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55044	17041-10000-37146	1003 E 4TH PL	90013	14	127-5A217  55	5163018002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.04219	-118.23383	Resubmitted due to more than 50% electrical design change from the original plan, service size changed to 1600A, adding more equipments and fire pump. Permit is covered under this new plan check number.  (old plan check# 16041-10000-45410) <<Original PC# 16041-10000-45410 --- FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION, DESIGN BUILD 216 STALL PARKING STRUCTURE (6 LEVEL PARKING WITH A 2 STORY (33,537 SF) OFFICE BUILDING ABOVE IT - BUILDING IS 8 STORIES TOTAL.)  SERVICE SIZE = 4000A. TOTAL SQ FT. 82143>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55045	19041-10000-17186	8730 N NORRIS AVE	91352	6	195B173   549	2408007010	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.2277	-118.37021	Plan check for a 3.8KW AC / 4kw DC roof mounted system with (1) inverter, (14) modules and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55046	17041-10000-33164	11450 W TUXFORD ST	91352	6	195B173   519	2408024001	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Issued	09/15/2017 12:00:00 AM	ADDRESS	34.22779	-118.38026	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 56275 SQ.FT (IN + OUT DOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55047	19041-10000-37311	6527 S CRENSHAW BLVD	90043	8	105B185  1333	4006018901	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	08/19/2021 12:00:00 AM		Permit Finaled	11/30/2023 12:00:00 AM	ADDRESS	33.97984	-118.33113	FULL PC FOR NEW MIXED USE PROJECT CONSISTING OF AFFORDABLE HOUSING APARTMENT. SCOPE INCLUDES A NEW SERVICE SIZE OF 1600A, 120/208V, 3PH, 4 WIRE, WHICH FEEDS A  800A HOUSE DISTRIBUTION BOARD WHICH FEEDS ALL ASSOCIATED HOUSE LOADS. THE NEW SERVICE ALSO FEEDS A 800A METER DISTRIBUTION BOARD. TOTAL AFFECTED AREA IS  37,779 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55048	14041-10001-35143	1286 W 36TH ST APT #1	90007	8	120B197   964	5040007019	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	34.02268	-118.29705	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 4.08 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: YINGLI YL255P-29b(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55049	17041-10000-17254	10250 W SANTA MONICA BLVD #1315	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PC FOR FIRST TIME TENANT IN WESTFIELD CENTURY CITY ""PRESSED JUICERY"". SUITE 1315, 497 SQ.FT"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55050	16041-20000-02326	9570 W PICO BLVD 2nd & 3rd-Floors	90035	5	132A167   257	4306002022	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.05499	-118.39734	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the 2nd and 3rd floors. Total lighting area = 11,997 sq. ft.Note: Building permits have been pulled under 15016-10000-27853 (2nd floor) and 15016-10000-27842 (3rd floor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55051	16041-10000-05668	2674 E ROSEVIEW AVE	90065	1	145-5A219 123	5453003019	RD3-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Expired	03/19/2018 12:00:00 AM	ADDRESS	34.09386	-118.22693	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. STANDARD PLAN IS BEING USED. (33)MODULES-SOLARCITY STANDARD(1)INVERTER-FRONIUS #PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55052	16041-10001-21790	145 S FAIRFAX AVE 2nd-3rd	90036	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.07288	-118.36166	02/16/17Changes to reflect what is on the field. All changes are clouded under delta 7. Rivising single line diagram to reflect what is on the field.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55053	12041-20000-19305	9613 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.24453	-118.59843	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55054	11041-10003-20387	8158 W BEVERLY BLVD	90048	5	138B173   448	5511006031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.07591	-118.36736	PLAN CHECK FOR DELTA 5 REVISION TO APPROVED PLANS. RELOCATE CIRCUITS AND ADDITIONAL BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55055	16041-10000-40688	327 N BOYLSTON ST	90012	1	135A211   216	5160022040	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Apartment			11/17/2016 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.06376	-118.25371	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR AN APATMENT BUILDING. 7 FA PANELS, 361 FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55056	11041-10002-00246	8725 N WOODMAN AVE	91402	6	195B153  1015	2637004026	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM			PC Approved	02/17/2011 12:00:00 AM	PIN	34.22835041	-118.43533744	TI IN DENTAL OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55057	14041-20000-21379	20924 W COSTANSO ST	91364	3	171B109   133	2167022003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.1654	-118.58916	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 4.73kW(22) EnPhase M215 microinverters(22) Hyundai M250MG pv module	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55058	15041-10000-33028	2280 S CENTINELA AVE	90064	11	123B149   977	4259026007	M1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.02970316	-118.45561355	TI AND CHANGE USE OF EXIST FIRST FLOOR TO RECORDING STUDIO AND REMODEL PORTION OR EXIST 2ND FLOOR OFFICE AREA.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55059	16041-20001-21217	10342 W DIAMOND ST LOT 12	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55060	13041-10000-05727	6600 N TOPANGA CANYON BLVD #51	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING RESTUARANT SPACE (CHANGING FROM CALIFORNIA PIZZA KITCHEN TO CHEESECAKE FACTORY).INDOOR AND OUTDOOR LIGHTING: 17130 SQRFT. SERVICE UPGRADED TO 1200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55061	15041-20000-39133	8350 N FULLBRIGHT AVE	91306	3	192B113   458	2781021017	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.22188	-118.57623	PV1, roof mounted solar panel, 6kW AC   (25)modules: #KU2656ZPA     (1)inverter: PVI-6000-OUTD-US-Z-A.  Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55062	12041-10001-10359	9301 N TAMPA AVE #58	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM			PC Approved	09/06/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK ONLY REVISION TO APPROVED PLANS. DELTA 4 & 5.  CHANGES TO T24 CALCULATION AND LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55063	17041-10000-07582	16665 W ARMINTA ST	91406	6	189B137    28	2205009030	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.21497	-118.49677	Plan check for Title 24 only in existing space wearhouse T.I. Total area: 20,000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55064	11041-10000-26781	16226 W VENTURA BLVD	91436	5	168B137   433	2284003026	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.15658	-118.48647	Existing restaurant.  Change of lighting to food prep area and new equipment.  PLAN CHECK ONLY for Energy.  All emergency lighting is existing with no change per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55065	15041-10000-12213	19807 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.85114	-118.28712	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 6440 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55066	15041-20001-18219	5825 W CAMERFORD AVE 1-34	90038	13	141B189   175	5534034017	R3-1XL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			09/09/2016 12:00:00 AM			PC Approved	09/09/2016 12:00:00 AM	ADDRESS	34.0845	-118.3253	((9/9/20116))changes to an approved set of plans.  change feeders from cooper to aluminum and remove cold water pipe grounding due to pvc inlet piping, grounding to remain ufer.  this is plan check only.  delta 2 changes only.pc for power and energy. apartment structure with 3 levels of Type VA construction above grade and 1 level Type I garage below grade. 34 residential units. total area 30311 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55067	18041-20001-42366	8046 W OKEAN TER	90046	4	156B173   296	5570019033	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.12433	-118.37302	Expedite per applicant rquestPlan check for PV roof mounted system, system size: 14.21KW AC, 19.36KW DC with 49 PV Modules and 49 Microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55068	11041-10001-21204	10000 W PICO BLVD BLDG 3	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00, 2691.00, 2695.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.05211	-118.40654	Plan check Delta 4 revision to approved plans. Revision consist of lighting, additional branch ckts, and review methane mitigation. BLDG. NO. 3 (Men's room section inc. outside lighting) OF POOL HOUSE AT THE HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDGS. NO. 1, 2, 3, & 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55069	19041-20001-08817	20229 W JUBILEE WAY	91326	12	213B113   396	2701087032	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.28317	-118.57444	05-07-2019 Changes to an approved set of plan, changes include remove load center, update service size, update PV system size to 8.45KW and inverter(7.6kW).permit fees $0.00 due to California Senate Bill 1222 and AB1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55070	10041-10000-12446	1828 S OAK ST 1st fl/mez-zanine	90015	1	124-5A203  22	5124017002	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2242.00	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Expired	10/30/2012 12:00:00 AM	ADDRESS	34.03705	-118.27728	remodel of part of the first floor mezzanineplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55071	16041-10001-29544	990 W 190TH ST Suite 440	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM			PC Approved	09/09/2016 12:00:00 AM	ADDRESS	33.85813	-118.29505	09/09/2016 Changes to an approved set of plans. Changes include lighting fixtures layout and reduce number of fixtures from 57  to 53 fixtures. (((((TITLE 24 PLAN CHECK ONLY.  TENANT IMPROVEMENT (4,573SF) TO EXISTING OFFICE SPACE. NEW LIGHTING AND RECEPTACLES.  NO CHANGE OF USE, NO CHANGE TO EXTERIOR.))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55072	18041-10000-24143	20362 W PLUMMER ST	91311	12	198B113    76	2748022077	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.24252	-118.57755	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55073	13041-10000-23547	2944 N GLENEDEN ST	90039	13	150A211    31	5442031901	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.10723	-118.24816	PLAN CHECK FOR POWER AND ENERGY. NEW 600 AMP SERVICE FOR MARSH PARK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55074	17041-20002-43487	1813 N AVENUE 53	90042	14	157-5A227 286	5479016020	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.12502	-118.19932	3/12/2018changes to an approved set of plans.  changes include downsize inverter to 5kw and downsized modules to 18.  This is plan check only.    (((Plan check for PV roof mounted system with battery back up system. Total system size: 6.5kW with 20 modules and 1 inverter(6.0kW) and 5.0KW Tesla battery. $0 fees due to Sennete Bill 1222)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55075	19041-10000-29434	1605 W GRAFTON ST	90026	13	141A209   240	5419009021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.20	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	02/24/2023 12:00:00 AM	ADDRESS	34.08087	-118.25524	New Fire Alarm System, scope of work includes one new fire alarm panel, and 112 new devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55076	17041-20000-40680	13772 N BORDEN AVE	91342	7	228B145    99	2502002048	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Issued	11/09/2017 12:00:00 AM	ADDRESS	34.32232	-118.46277	PV1.  Install 7.8 kW roof-mounted grid-tied PV system. (30) modules with power optimizers and 6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55077	19041-10001-07450	12309 W MILBANK ST	91604	2	168B165   986	2364014031	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.15326	-118.40116	SUPPLEMETAL FEE EXPEDITEPLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(DELTA SILIVIA 5.2TL) WITH 2 ENERGY STORAGE SYSTEM(POWER WALL) USING SOLAR TILES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55078	11041-10000-08318	11111 W SANTA MONICA BLVD # 1810	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.04771	-118.44481	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55079	15041-10000-36931	2707 S CASTLE HEIGHTS PL	90034	5	126B165   954	4309024018	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Expired	12/01/2017 12:00:00 AM	ADDRESS	34.03858	-118.39702	PV1INSTALL ROOF MOUNTD PV SYSTEM SIZED 8.2KW INTERCONNECTED WITH MSP.(40) MODULES(1) PVI 8200 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55080	17041-10000-17089	2136 W WASHINGTON BLVD	90018	10	126B193   944	5074033042	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.02	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.03974	-118.30707	PC for power and energy for change of use TI project for new adult day care center. Scope includes having exisiting panels with new circuit and new equipment. Total affected area is 21750 sqft. Plan checker to verify outoor area during verification.building #16016-10000-22539	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55081	19041-10000-51717	1183 N KINGSLEY DR	90029	13	144B193   400	5537010007	RD1.5-1XL	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.09287	-118.30261	NEW PV1 INSTALLATION 3.84KWdc (3KWac & 3.51KWcec) using 13 REC295TP2 MODULES, 13 SE P320 POWER OPTIMIZERS & 1 SE3000H-US CENTRAL INVERTER.CONNECTED TO AN EXISTING 100 AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55082	13041-10000-25006	13337 W ASTORIA ST	91342	7	228B157    12	2582015013	(T)RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.32551	-118.42372	PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 6 KW DC IN A 2-STORY HOUSE. TRANSFORMERLESS SYSTEM, UNGROUNDED.(24) MODULES: CS6P-250P(1) INVERTER:  POWER-ONE-PVI-6000-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55083	19041-10000-28008	935 N GALLOWAY ST	90272	11	129B129   827	4423019022	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.0465	-118.52106	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 3.48KVA PV SYSTEM CONSISTING OF 12 MODULES USING IQ7PLUS-72-2-US MICROINVERTERS CONNECTED TO EXISTING 400A SERVICE WITH DEDICATED PV BREAKER ON PANEL (200A MAXIMUM).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55084	17041-20000-35684	845 S MANHATTAN PL 1-33	90005	4	132B193   754	5093002024	R4-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			Reviewed by Supervisor	10/11/2017 12:00:00 AM	ADDRESS	34.05676	-118.31027	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.54 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55085	14041-20000-12110	21329 W NORDHOFF ST UNIT C	91311	12	198B105   169	2746010002	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.23562	-118.59582	TI in single-story general office/warehouse tenant space for renovation of break room, restrooms, and corridors.  Plan check for Title 24 Part 6 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55086	11041-10000-03218	1617 W BEVERLY BLVD	90026	13	135A207   244	5159012029	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2083.00	Electrical	Electrical	Commercial			02/18/2011 12:00:00 AM	02/18/2011 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	PIN	34.06391785	-118.26334214	new two story fire alarm, one panel and 110 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55087	16041-10000-25272	17350 W SUNSET BLVD BUILDING-AB	90272	11	126B117   516	4415018016	C2-1VL, [Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.04043	-118.55311	**Plan 2 of 2 PLAN CHECK FOR POWER AND ENERGY ON (E) EXISTING CONDOMINIUM BUILDING. INSTALL NEW MECHANICAL EQUIPMENTS. VOLTAGE RATING IS 4800V, NEWLY CONNECTED LOAD > 400A. TOTAL AFFECTED AREA: 3,467 SQ.FT*This plan is 2 of 2. One Service feeding both buildings AB, and CD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55088	19041-10000-03017	3011 E PICO BLVD	90023	14	118-5A223 104	5169004001	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Issued	03/28/2019 12:00:00 AM	ADDRESS	34.01862	-118.21515	PLAN CHECK FOR POWER UPGRADING EXISTING SWITCHBOARD TO 1200A. PROVIDING NEW SWITCHBOARD WITH MULTI METER SECTION TO SEPARATE EACH TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55089	12041-20000-30115	245 S MAIN ST	90291	11	111B141   545	4286017***	(Q)C4-2D	West Los Angeles	Venice	Venice		2734.00	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	33.99681	-118.47872	Install new circuits for power and lighting for new coffee shop.   Plan check for T24 lighting plan check only.  Spazio Caffe.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55090	15041-20000-18041	1430 E WASHINGTON BLVD	90011	9	120A213   272	5129006031	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Closed	06/27/2016 12:00:00 AM	PIN	34.02232585	-118.24732255	Changes to approved set of plans. Master application # 14041-20000-07575.  office. Addition (4) 200A panels to existing equipments. Total area: 60,000 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55091	07041-20002-12647	1020 S OLIVE ST	90015	14	127-5A209 286	5139012008	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.04162	-118.2599	Modification an approved set of plans.  All changes have been clouded.  Changes are an addition of LED light fixtures on rooftop and 2 light fixtures in the corridor and stair wells.  Plan check is for energy only.   <<<<<<<<Redesigned the mix use units, offices and dormitories(100 units) and classrooms.  Original submittal was under 05041-10000-12420.Changes from previous approved plan.  Permit is under: 07041-10000-12647.  Plan check ONLY.>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55092	10041-20000-23114	14806-14812 W OXNARD ST	91411	2	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.17923	-118.45543	"Plan check power and energy for site lighting. Site lighting supplied from HV-10. Core and shell under 10041-20000-16329. ""COMPLY WITH DEPARTMENT ORDER effective date10/27/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". Allpermits shall be for the same time period limitation."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55093	11041-20001-01666	6110 N VARIEL AVE	91367				WC		Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center			Electrical	Electrical	Commercial			03/25/2011 12:00:00 AM			PC Approved	04/04/2011 12:00:00 AM	ADDRESS	34.18136	-118.59257	energy plan check office revision only to title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55094	18041-20000-42544	6708 N NEVADA AVE	91303	3	180B101   162	2139007027	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.19218	-118.609	PV1.  Install 15.275 kW roof mounted grid tied PV system.  (47) modules with (2) 7.6 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55095	12041-10000-06711	189 S THE GROVE DR F5 & F6	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	First  time tenant in a retail space # F5 & F6.   Plan check for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55096	10041-20000-00420	10585 W SANTA MONICA BLVD	90024	5	132B157  1074	4326033042	[Q]C2-1VL-O	West Los Angeles	Westwood			2656.00	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Finaled	03/10/2010 12:00:00 AM	PIN	34.05439965	-118.42928472	Intalling lighting in commercial building. This plan check is only for title 24 energy and power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55097	14041-10000-25053	9448 W PICO BLVD	90035	5	132A167   237	4306003001	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.05508	-118.39513	"PROPOSED NEW 2-STORY OFFICE, MARKET & FOOD-TO-GO ADDN (45'10""X25'7"") TO EXISTING 1-STORY AUTO SERVICE BLDG WITHIN EX GAS STATION."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55098	19041-10000-03623	1141 W 187TH PL	90248	15	060B197   413	6109015018	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	33.86065	-118.29391	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 16 MODULES (Q-CELL 305) , 16 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 4.8KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55099	12041-10002-22577	7270 W MANCHESTER AVE	90045	11	096B157   625	4119026042	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Apartment			06/25/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	33.95959	-118.42143	changes to approved set of plans: CHANGE FEEDERS COMING FROM MS-2 TO DWELLING PANELS (lengths have shrunk). correction to be added for field verification by inspector. 6 additional plan check hours per supervisorNEW 6 STORY 260 UNITS APARTMENT BLDG WITH 3 LEVELS UNDERGROUND PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55100	14041-20001-01481	10521 N SEPULVEDA BLVD	91345	7	207B145   574	2649013004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.26162	-118.46772	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTA SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55101	15041-20000-12830	6801 N VAN NUYS BLVD	91405	6	183B149   778	2219025030	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.19423	-118.44897	Title 24. TI to existing commercial space. Change of use from a shoe store to a financial bank services center. Plan check for energy only. Adding new lighting including emergency. Total Sqft. 5,733	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55102	15041-20001-25655	6245 W WILSHIRE BLVD	90048	5	135B177   481	5510027014	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.06356	-118.36478	10/10/2017changes to an approved set of plans.  changes include exterior lighting and revised enery outdoor calculations.plan check for outdoor energy only.   (((((PC FOR POWER AND ENERGY FOR A 20 STORY HIGH RISE MIXED USE BUILDING.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55103	14041-20000-15626	4131 N ELLENITA AVE	91356	3	165B117   459	2180005012	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Expired	08/01/2016 12:00:00 AM	ADDRESS	34.14508	-118.55917	New roof mounted PV system with 300W Optimizers, and 6KW and 3.8KW transformerless inveters.  Total system size is 11KWdc.  Note: Permit is $0.00 due to Senate Bill 1222 from 2012	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55104	17041-10000-09560	6254 N TAMPA AVE	91335	3	177B117   185	2128029027	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.18443	-118.55325	PV1, ROOF MOUNTED SOLAR SYSTEM TO A SFD, SYSTEM CONSIST OF AC MODULES, TOTAL SYSTEM SIZE IS 12.6 KW AC.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55105	10041-10000-09795	5609 W SUNSET BLVD	90028	13	147A193    74	5544028026	C2-1	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM	07/22/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.09825	-118.3118	TI, CHANGE FROM RESTAURANT TO 7-ELEVEN STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55106	15041-20000-26423	13630 W SATICOY ST	91402	6	186B157   140	2214025004	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.20928	-118.42941	Plan check for power and Title-24 (energy).  Total area = 21,127 sq. ft.  T.I. to existing commercial space.  Complete electrical renovation for new restaraunt space.  New 1,200 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55107	18041-10000-34454	3500 W WILSHIRE BLVD # 201	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM			PC Info Complete	09/10/2018 12:00:00 AM	ADDRESS	34.06157	-118.30077	Energy plan check for an existing  FOOD COURT COMBINING 2 SPACES INTO 1 T.I. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55108	13041-10000-33136	7381 W FOOTHILL BLVD	91042	7	202-5A199  29	2568009026	(T)MR1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.25128	-118.2928	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 2220 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55109	07041-10001-24502	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-4	Central	Westlake			2089.02	Electrical	Electrical	Apartment			01/10/2011 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.05562	-118.27458	Delta 7, 8, and 9  modifications on pages E0.04, E1.00, and E1.01 of approved set of plans for a new 90 unit apartment building.  Original permit issued on application # 07041-10000-24502.  Installation of fire pump, jockey pump, panel G3-R101, Dist board R1-101, feeders to RDB1U and RDB2U, and change feeders to various motor loads and panel GL1U/H1 supplied by HMS1U.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55110	15041-10004-32591	7809 N BOTHWELL ROAD	91335	3	189B117   774	2105006016	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM			PC Approved	03/29/2016 12:00:00 AM	ADDRESS	34.21248	-118.56137	03/29/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED. CHANGES INCLUDE RELOCATING/REARRANGING SOLAR MODULES ON ROOF-LAYOUT. NOTE: PERMIT PAID UNDER PCIS#15041-10000-32591((((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.15KW INTERCONNECTED WITH MSP.(28) MODULES(2) INVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55111	19041-20000-06694	21820 W BURBANK BLVD Ste 325	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.17228	-118.6032	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55112	17041-10000-23917	13573 N GLADSTONE AVE	91342	7	228B153   509	2504009010	RA-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.31855	-118.43852	Note: Permit Fees are $0 due senate bill 1222.PV1, install new solar system on existing residential roof-top. Total system size is 15.2 kW AC, (69) modules, and (2) inverters 7.6kW each.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55113	10041-20000-12292	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	PIN	34.12750533	-118.21285206	ADDITION/ REMODEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55114	17041-20000-12970	19101 W LANARK ST	91335	3	189B121   102	2104002034	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Issued	04/20/2017 12:00:00 AM	ADDRESS	34.21756	-118.54949	PV1.  Install 3.6 kW roof mounted grid tied PV system.  Standard plan.  (16) modules with (1) 3.6 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55115	13041-10002-30078	3292 S WOODBINE ST	90064	5	123B161   770	4316021011	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.03153	-118.406	Expedited RSES plan check per applicant request.(((PV1, Install 7.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 29 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55116	19041-10000-18039	6705 N RESEDA BLVD	91335	3	180B125   200	2126034023	[Q]C2-1VL-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.19218	-118.53631	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55117	14041-10000-05394	4222 N VINELAND AVE	91602	2	165B173  1260	2366020002	[Q]C2-2D	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.1455	-118.37004	Existing hotel lobby renovation (low-rise).  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55118	13041-10002-30061	3503 E 3RD ST	90063	14	124-5A229 166	5179014002	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.03404	-118.19414	Expedited RSES plan check per applicant request.(((PV1, Install 2.5 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 10 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55119	12041-10001-13858	21730 W SHERMAN WAY	91303	3	183B105   151	2111025002	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.20086	-118.60267	Plan check for power only.  Plans were previously approved under 12041-10000-13858.  Changes were made to the approved set of plans.  The changes are the removal of load from Panel B and shifted over to Panel E.  No changes to the lighting have been made.  <<<<<Plan check for power. Changes to original approved plan (changes are to power only, not lighting) under 11041-1000-11755:[CHANGE OF USE FROM RETAIL TO RESTAURANT IN EXISTING SINGLE STORY BUILDING.  PLAN CHECK FOR ENERGY AND POWER>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55120	16041-30000-08080	350 S GRAND AVE #2800	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for Title 24 only T.I. on existing high-rise building. Total area: 8,120 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55121	12041-20000-24434	1100 W WILSHIRE BLVD BASEMENT	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	ADDRESS	34.05228	-118.26384	Plan check for energy and emergency lighting. Indoor garage converted to storage for mixed use building. high rise. 9715 sqft. BASEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55122	15041-20001-01907	1254 E 54TH ST	90011	9	108B209   557	5104015005	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	33.9938	-118.25296	Change to approved set by rotating the PV module on the roof plan.(((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55123	16041-20000-11654	7206 N SAUSALITO AVE	91307	12	183B101    94	2022020011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.20125	-118.6159	PV1.  Install 5 kW roof-mounted PV system.  (20) modules with 5 kW inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55124	16041-20000-45838	5924 E WEAVER ST	90042	14	156A229   341	5485026014	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.20	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.12106	-118.18948	Plan check for a PV1 roof-mounted system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55125	10041-10001-10865	770 W WILSHIRE BLVD GND & 3RD-FLOORS	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM	07/22/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.04914	-118.25811	PARTIAL TENANT IMPROVEMENT ON 1ST FLOOR AND FULL FLOOR REMODEL ON 3RD FLOOR LEVEL OF (E) OFFICE BLDG.  (N) INTERIOR WALL, CEILING SYSTEMS, MILLWORK AND FINISHES TO RECONFIGURE OFFCE AREAS AND EXIT STAIRWAY DOOR ON 3RD FLR. PLAN CHK ISFO RTITLE 24 AND 3 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55126	14041-20000-10177	8635 W 3RD ST 850 WEST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.07373	-118.38073	TI to medical existing office building.  No surgery and no procedures being done, no medical equipment install.  Rolocate subpanel, and install new branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55127	15041-20000-22533	3450 S WATT WAY Room#135	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.02275	-118.28604	Plan check for Title 24 only in existing space. Total indoor area: 79 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55128	18041-10000-46095	511 N POINSETTIA PL	90036	5	141B181  1122	5526022014	R1V2	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.08062	-118.34877	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 37 MODULES (SOLARIA POWER XT 360R-PD), 37 MICROINVERTERS (ENPHASE IQ7-PLUS-72-2-US). SYSTEM SIZE IS 13.32 KWdc. SCOPE INCLUDES 80amp  AC COMBINER BOX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55129	12041-20000-19166	318 N LA BREA AVE	90036	5	138B181   308	5525032009	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM			PC Approved	09/11/2012 12:00:00 AM	ADDRESS	34.07682	-118.34384	Change of use from grocery market to retail store.  Install indoor general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-90000-17572	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55130	15041-20000-11567	12751 W MILLENNIUM B-135	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Plan check for power and energy for New restaurant (800 Degree Pizzeria). Total newly connected load: 559A. Area: 3630 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55131	19041-20000-51235	8523 W DAY ST	91040	7	204B189   898	2560020011	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Issued	12/12/2019 12:00:00 AM	ADDRESS	34.25436	-118.3187	PV1. INSTALL 9.76 KW DC PV SYSTEM WITH (32) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55132	12041-10000-14254	11941 W SAN VICENTE BLVD	90049	11	129B145    64	4404025025	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	34.0528	-118.47095	Plan check for energy and emergency lighting. CVS. 187 sqft addition.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55133	14041-10006-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Issued	05/18/2016 12:00:00 AM	ADDRESS	34.0504	-118.26023	"Changes to permitted plans. Plans identify(clouded) each change on each sheet. CHANGES INCLUDE  NEW 30KVA XFMR FEED FROM EXISTING PNL TO PROVIDE 120/208V TO NEW PANEL WHICH SUPPLIES 15BRANCH CKTS AND A 18KVA UPS FOR DRAPER EQUIPMENT ((((((((((PLANCHECK FOR POWER AND ENERGY. HIGH RISE CORE AND SHELL BUILDING INCLUDING 5 LEVEL PARKING GARAGE. "" WILSHIRE GRAND "" PROJECT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55134	17041-10000-02326	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.13829	-118.34154	FULL PLAN CHECK REMODEL POOL BATH SOUTH BLDG. 5 OF 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55135	14041-20001-08408	6326 N LINDLEY AVE	91335	5	177B125   148	2123022001	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	PIN	34.18466698	-118.52697308	Fee for expedite only.****Roof mounted PV system on child care with size 7.2 KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55136	19041-20000-37173	6701 S CENTER DR WEST 10th floor	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	Restroom remodel on 10th floor of (E) office building P.C for title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55137	16041-10000-28874	1607 S GRAND AVE	90015	14	124-5A207 187	5134014020	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.03549	-118.2667	Plan check for T-24 only. Remove outdoor HID fixtures and replace with new LED fixtures.  Total area: 14,061 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55138	16041-10002-07103	216 W 47TH ST	90037	9	112-5A203 385	5110011006	R2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.00083	-118.27677	change to approved set of plans. location of modules change and showing disconnect at detached structure. this application will cover permit fees for panel upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55139	13041-10000-15861	6601 N CAPISTRANO AVE	91307	3	180B101   334	2038031013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	09/10/2013 12:00:00 AM	ADDRESS	34.19073	-118.61682	PV1 6.37KW XFRMLESS. 1STORY. NONSTD. ROOFMOUNT. (1) solaredge SE6000A-US. (26)TRINA TSM-245PC05.18} with optimizers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55140	12041-10000-26478	4550 W PICO BLVD # C1-306	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	Plan check power & energy for first time tenant. New Carter's retail store.  Suite #C2-06. New panels, ckts, and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55141	10041-10000-21480	410 N HAWAIIAN AVE 1-100	90744	15	030B201   819	7417012905	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			10/28/2010 12:00:00 AM	12/10/2010 12:00:00 AM		Permit Finaled	09/13/2011 12:00:00 AM	ADDRESS	33.7736	-118.27616	new fire alarm system for new 3 story residential bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55142	17041-20000-38969	509 S BENTLEY AVE	90049	5	135B145   478	4366033026	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.06639	-118.4593	PV1.  Install 14.15 kW roof mounted grid tied PV system.  (41) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55143	14041-20000-27401	10700 W SANTA MONICA BLVD SUITE 213	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM			PC Info Complete	10/03/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING LIGHTING TO OFFICES, USING EXISTING POWER EQUIPMENT.  1369 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55144	17041-20000-30257	6940 N VANSCOY AVE	91605	2	183B161   612	2324030040	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	PIN	34.19690011	-118.40605312	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55145	16041-10000-42280	649 W ADAMS BLVD	90007	1	123A203   204	5124026013	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.02895	-118.27743	PLAN CHECK FOR FIRE ALARM SYSTEM FOR EXISTING LOW RISE-BUILDING WITHIN SCHOOL CAMPUS.TOTAL FIRE ALARM DEVIDES 49 DEVICES AND 1 FIRE ALARM CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55146	13041-20001-33968	7404 N WISCASSET DR	91307	12	186B085   154	2017036012	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			PC Approved	12/27/2013 12:00:00 AM	PIN	34.20626576	-118.65928574	((Expedite fees))PV1 GROUND MOUNTED SYSTEM. TOTAL SYSTEM SIZE 10KWAC. 40 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55147	17041-10000-04303	12950 W PIERCE ST	91331	7	207B161   165	2536016014	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.26561	-118.41533	PC for indoor and outdoor Title 24. Removing HID fixtures and replacing them with new LED onesArea: 138,810	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55148	14041-10000-26586	9620 S AIRPORT BLVD	90045	11	093B169   171	4125023034	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	33.94842	-118.38574	Plan check for title 24 energy. High rise, work is on 2nd story. No change in occupancy, Gym in side. 2061 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55149	13041-10000-25778	505 S VIRGIL AVE ste 101	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.0649	-118.28724	TITLE-24 ONLY; WORK IS FOR INTERIOR TENANT IMPROVEMENT FOR DOCTOR'S OFFICE, IN STE 101. NO SURGICAL OPERATION WILL BE DONE IN THE DOCTOR'S OFFICE PER APPLICANT. TOTAL AREA IS 1585 SF. PERMIT TO BE PULLED @ THE ELECTRICAL PLAN CHECK COUNTER 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55150	13041-10000-03939	1355 S FLOWER ST	90015	9	126A205    96	5134010018	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			02/14/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.03876	-118.268	PLAN CHECK FOR INSTALLATION OF NEW FIRE ALARM SYSTEM ON A 7 STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55151	12041-10000-19190	10019 N GENESTA AVE	91325	12	204B133   568	2694009004	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	11/02/2012 12:00:00 AM	ADDRESS	34.25305	-118.50419	Plan check new roof mounted 9.69KW photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55152	10041-10000-08134	6370 W SUNSET BLVD	90028	13	147A187   584	5546015047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.09768	-118.32832	T.I. for existing building.  Install general lighting in kitchen area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55153	13041-10000-16377	5940 W CARLOS AVE	90028	13	148-5A191 397	5545003027	R4-2	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Apartment			06/20/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.10277	-118.31953	FA. REPLACEMENT OF FA PANEL AND ASSOCIATED INPUT DEVICES. 8 STORIES. silvercrest residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55154	15041-10000-21994	11650 W PICO BLVD	90064	11	123B153   717	4260033033	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			07/14/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.03185	-118.4448	PC FOR POWER AND ENERFY FOR NEW MIX USE OF 71 UNITS APARTMENT, (5) RETAIL STORES,  AND  (2) SUBTERRANEAN PARKING BUILDING. SCOPE INCLUDE 3000-AMP SERVICE 3-PHASE 120/208V. AND  (15) TYPICAL UNITS FOR APARTMENT UNITS. TOTAL AREA FOR T-24 IS 59,885-SQ FEET. ALL MIS.-LOAD IN RETAIL PANEL ARE FOR DESIGN ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55155	14041-20001-22688	17543 W CHATSWORTH ST	91344	12	207B129   401	2712027029	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	09/10/2014 12:00:00 AM	ADDRESS	34.26507	-118.51683	Modifications to approved set.  Change of track lighting current limiting device and other minor changes to circuiting.  (((TI for (E) commercial retail space.  Plan check for energy conservation standards.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55156	18041-10000-11944	921 N VIGNES ST	90012	14	132A217    58	5409016006	[Q]M3-1-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.05741	-118.23197	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55157	17041-20001-22684	10810 N SWINTON AVE	91344	12	207B137   211	2680006012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.26661	-118.48575	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55158	16041-10000-28083	601 W 5TH ST ste #600	90071	9	130-5A211  96	5151017029	C2-4, D	Central			YES	2075.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	TITLE 24 FOR EXISTING COMMERCIAL BUILDING T I AT 6TH FLOOR(SUITE 600).TOTAL AREA = 2949 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55159	17041-10000-04352	4550 N VAN NUYS BLVD #A1	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Expired	08/18/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	Plan check for Title 24 only in existing space. T.I. in restaurant load less than 400A. Total area: 3,015 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55160	19041-10000-10475	1031 S BROADWAY 11TH FL	90015	14	126A209    99	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	02/20/2024 12:00:00 AM	ADDRESS	34.04041	-118.2583	Full plan check per applicant request; Scope include new lighting and equipment with a total area of 16,050-SQ FT for an office T.I  on the 11th floor of a high rise building. Install 5 new panelboards fed from (E) Dist. BoardBld #: 19016-10000-08192	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55161	17041-10000-22154	11052 N INDEPENDENCE AVE	91311	12	210B105   271	2706001038	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.11	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.27154	-118.59103	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55162	13041-20000-31343	14117 W HUBBARD ST 8-9	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.29849	-118.44081	PC FOR POWER AND ENERGY. NEW DENTAL OFFICE. MEDICAL AND CLINICAL CARE. TOTAL AREA 2658 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55163	15041-20000-38205	6115 W SUNSET BLVD B100&200	90028	13	147A189    24	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.09819	-118.32261	Plan check for Title 24 only for exist space on 1st floor(#B100) & mezzanine and 2nd floor(#200) . Total area:8,761sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55164	18041-10000-14938	5809 S MAIN ST	90003	9	108B201  1349	5101023014	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	33.98945	-118.27417	PC FOR NEW ONE STORY RETAIL AND COIN LAUNDRY BUILDING FOR POWER AND ENERGY. SCOPE INCLUDES NEW SERVICE 800A 120/240V WITH NEW SUBPANELS CIRCUITS AND EQUIPMENT .TOTAL AFFECTED AREA 11585 SQ.FT B#17010-10000-03955	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55165	13041-10001-04444	19943 W HEMMINGWAY ST PV1	91306	3	189B113   718	2106003100	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2013 12:00:00 AM			PC Approved	06/28/2013 12:00:00 AM	ADDRESS	34.21414	-118.56815	Applicant submits for electrical plan check due to change of design from transformered inverters to transformerless.  {13 modules: Trina Solar TSM-245} {Transformerless inverter: Power-One PVI-3.0}Original Work Description: INSTALL ROOF-MOUNTED SOLAR, INTERCONNECT W/ MAIN SERVICE PANEL.  SYSTEM SIZE 3.185KW Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55166	18041-10000-23290	1400 S LINCOLN BLVD	90291	11	111B145  1013	4243004034	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	33.99802	-118.46056	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55167	13041-10000-01797	10782 W WEYBURN AVE	90024	5	132B153    41	4360004022	R1-1-O	West Los Angeles	Westwood	Westwood		2652.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	ADDRESS	34.06183	-118.43954	PV1 ROOF MOUNTED SOLAR INSTALLATION USING MICROINVETER STANDARD PLAN. SINGLE STORY HOUSE. SYSTEM SIZE IS 3.024 KW. USING 14 MODULES IN A SINGLE CIRCUIT. [INVETER: ENPHASE # M215-60-2LL-S22 |||| MODULE: REC # REC 245 PE]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55168	17041-10002-01430	2694 W JAMES M. WOOD BLVD	90006	1	132A201   210	5077028002	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM			PC Approved	03/09/2017 12:00:00 AM	ADDRESS	34.05575	-118.28671	Changes to an approved set of plans. All changes are clouded. Changes include resizing equipment grounding size from the inverter to the AC disconnect, resizing AC disconnect from 30A to 60A, and relocating modules on the roof-layout.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55169	15041-10000-13032	1180 W OAK GROVE DR	90041	14	159A229    73	5480016016	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.13143	-118.19289	PV1, install 6.76 kw dc roof-mounted solar array tie with main service panel. (26) Modules: KYOCERA  KU2606XPA(1)INVERTER: ABB PV1-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55170	10041-30001-00272	11301 W PICO BLVD	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM			PC Approved	02/11/2010 12:00:00 AM	ADDRESS	34.03517	-118.43924	2-11-10 - Supplemental is a recheck of previously approved plans because plans were lost.  P/C is for Energy only :: TI - existing Best Buy remodel of area clouded in plans - Permit is for new panel, new equipment + 75 kVA XFMR, new ckts, new lightingis for display only.  New load is < 400 A.  P/C is for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55171	16041-20000-35699	5166 N AVENIDA HACIENDA	91356	3	171B125   434	2161023004	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	02/24/2018 12:00:00 AM	ADDRESS	34.16517	-118.5335	"""0$ permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 24.85 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55172	18041-10000-23341	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	09/22/2022 12:00:00 AM	ADDRESS	33.78808	-118.29535	PLAN CHECK FOR POWER FOR NEW - Installation of foundation for fuel cell generator with concrete pads. - TOTAL NEW CONNECTED POWER = 2162KVA SYSTEM	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55173	14041-20001-33531	3354 N WRIGHTWOOD DR	91604	2	159B173   356	2380038008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM			PC Approved	06/02/2015 12:00:00 AM	ADDRESS	34.13238	-118.37327	Changes to an approved set of plans. Changes have been done to the PV module layout, and to the amount of modules per string; the new layout has 5 strings instead of 6 (10+10+11+13+11).*****Previous Work Description*****PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 11.825kW. Ungrounded system.55 EnPhase M215-IG microinverter with 55  250W pv modules across 6 strings (10+9+10+9+9+8).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55174	17041-20000-01536	10400 N SEPULVEDA BLVD tmobile-1c	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.25939	-118.46706	"ti to a first time tenant (tmobile) unit ""1C"".  plan check for power and energy.  total square footage 2038."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55175	19041-20000-03672	1603 S LA CIENEGA BLVD	90035	5	129B173   902	4303028031	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.04895	-118.37642	Plan check for Title 24  for new parking garage. Total area: 3053 sq ft. Newly connected load is less 400A. B#17014-30000-02711	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55176	18041-10001-23117	450 S WESTERN AVE 204	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM	ADDRESS	34.06562	-118.30887	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE NEW LIGHTING SYSTEM AND NEW POWER LAYOUT FOR FIRST TIME TENANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55177	15041-10000-24830	7228 N AMIGO AVE	91335	3	183B121  1185	2118028063	(T)(Q)R3-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			08/03/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.20195	-118.53846	NEW FIRE ALARM SYSTEM FOR A 3 STORY, 22 UNIT APARTMENT BUILDING . 82 DEVICES. ONE FIRE ALARM PANEL AND CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55178	14041-10000-13138	970 N MONUMENT ST #204	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Apartment			05/16/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.04646	-118.52393	Ti , two story commercial , title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55179	15041-10000-24386	300 S GRAND AVE LOWER-PLAZA	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	PC FOR ENERGY AND EMERGENCY LIGHTING ONLY. T-24 SCOPE OF WORK INCLUDES NEW LIGHTING IN THE COMMON AREA. TOTAL  SQ FT = 8100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55180	15041-20000-31875	5757 W WILSHIRE BLVD 5th Floor	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Closed	05/05/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Work is being done on the 5th floor. Total lighting area = 4,577 sq. ft.Note: Building permit filed under application 15016-10000-16497	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55181	11041-10000-10163	1741 N CHEROKEE AVE Office	90028	13	148-5A185  32	5547009014	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	06/24/2011 12:00:00 AM	ADDRESS	34.10281	-118.33488	T24 for remodeled office building.  On same lot as new garage building.  See existing permit 11041-10000-08849 for this building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55182	14041-10000-06152	629 E MILFORD ST	90042	14	150A231   112	5312023066	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	34.10626	-118.18228	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(8) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55183	14041-20000-13680	835 W WEST 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM			PC Approved	05/22/2014 12:00:00 AM	ADDRESS	34.02321	-118.28491	Renovation of (2) restrooms in USC University Religious Center.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55184	17041-20001-14697	12370 N TELFAIR AVE	91342	7	219B145   492	2604032026	RE9-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.29518	-118.46073	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55185	15041-10001-24075	1500 W PACIFIC COAST HWY Bldg L	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION OF 54 DEVICES AND 1 POWER SUPPLIES, FOR FUTURE ADA REQUIREMENT.  ((((NEW FA SYSTEM FOR A New 3-story, 20 unit apartment with garage, 53 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55186	16041-10000-12538	1418 W 36TH ST	90018	8	120B193  1296	5041018019	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Expired	05/11/2018 12:00:00 AM	ADDRESS	34.02268	-118.30082	PV1, INSTALL 3.825 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(15) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55187	15041-10000-02965	9211 N CAYUGA AVE	91352	6	198B165   260	2629013070	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.2369	-118.39904	PV1 STANDARD PLAN RESIDENTIAL. 19 MODULES AND 1 INVERTER. 6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55188	19041-20000-31094	8500 N CAPISTRANO AVE	91304	12	192B101   227	2004017027	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.22459	-118.6163	PV1. INSTALL 12 KWDC/11.094KWAC SYSTEM SIZE (40) MODULES WITH MICROINVERTER (YC600).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55189	17041-10001-30156	8319 S MAIN ST	90003	9	099B201  1376	6031036029	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2397.02	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM			PC Info Complete	07/03/2018 12:00:00 AM	ADDRESS	33.96357	-118.27404	DELTA 2 Changes to an approved set of plans dated 6/25/2018. Changes include relocation of service,  addition of 3 new planes and revision of single line diagram, Revisions include change of feeder length, panel name. TI TO EXISTING MULTI TENANT BUILDING. UPDATING SERVICE AND DISTRIBUTION TO RESERVE AND REBUILD TENANTS. REFEED SOME EXISTING LOADS. NEW 800 SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55190	16041-20001-38333	22728 W OXNARD ST	91367	3	177B097   532	2040002003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.17906	-118.62183	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE; 24 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55191	14041-20000-19404	1322 S BRINKLEY AVE	90049	11	129B137   272	4407011014	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.05128	-118.49655	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.84KW INTERCONNECTED WITH MAIN SERVICE PANEL.(41) ENPHASE MICROINVERTERS M250(41) SOLAR WORLD SW280 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55192	16041-10000-29883	1366 S SPENCE ST	90023	14	118-5A225 351	5191021019	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.01762	-118.20267	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 5940 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55193	16041-10000-05589	8814 N HAYVENHURST AVE	91343	12	195B137   565	2688034006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.23074	-118.49367	PV1, rooftop solar installation 3.2kW AC system(15) HYUNDAI HiS-S260RG(15) M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55194	13041-20000-21117	3256 S BUTLER AVE	90066	11	120B157  1011	4250020010	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.0208	-118.4307	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING TOTAL OF 17 MODULES. 3 STRINGS/ INVERTER. NONSTANDARD PLAN. TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55195	10041-10000-15866	811 W WILSHIRE BLVD 5TH FL	90017	9	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.04973	-118.2584	TENANT IMPROVEMENT FOR OFFICE 2,860 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55196	15041-10000-09464	1412 N GLENDALE BLVD	90026	13	141A209   335	5419020017	C2-1L, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.08004	-118.25986	PC FOR ENERGY, T24. TI, CHANGE OF USE FROM RETAIL TO BAR/CAFE. TOTAL AREA 1901 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55197	16041-20002-44549	1060 S BROADWAY	90015	14	126A209   131	5139014011	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.0397	-118.25861	2/28/2019changes to an approved set of plans.  changes noted delta 8.  changes to consolidated services into (1) 2000 amp.  Addition of panels and associated circuits.  plan check for power only.  ((((Plan check for power and energy. Remodel (E) 10-story high rise building, convert from office to hotel. (2) New 1000A services. ~174 hotel units. T24: indoor area- 188,264sqft.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55198	19041-10000-06908	1156 S CLARK DR	90035	5	132B169   806	4332014901	R3-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.05555	-118.38462	REMOVE HID FIXTURES AND REPLACE WITH NEW INDOOR AND OUTDOOR LED FIXTURES-T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55199	15041-10000-03522	1232 W LEIGHTON AVE	90037	8	117B197  1163	5037003002	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.01311	-118.29842	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (22) modules, and (1) inverter. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55200	18041-10000-43887	10316 N NORRIS AVE STE A	91331	7	204B165    84	2537003036	[T][Q]MR1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Issued	11/16/2018 12:00:00 AM	ADDRESS	34.25717	-118.40275	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55201	14041-20000-26392	13964 W SYLVAN ST	91401	2	177B153   241	2239009029	RS-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.18429	-118.43777	CENTRAL STRING INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55202	11041-20001-06937	12300 N GLADSTONE AVE	91342	7	219B161   303	2525028001	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.29325	-118.41006	Changes from previously approved plans.  Changes include additional panels, branch circuits, and lighting.  Plan check for power and energy.  *****New 600 amp service for an existing warehouse.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55203	17041-10000-29217	10900 N YOLANDA AVE	91326	12	210B121   710	2717013023	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.26861	-118.54081	PLAN CHECK FOR ROOF MOUNTED SOLAR SYSTEM ON SLD. CENTRAL INVERTER SYSTEM RATED AT 5.0 KW ACSCOPE INCLUDES 26 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55204	12041-10000-28195	10114-10116 W EMPYREAN WAY Bldg #14 &-#15	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Apartment			11/26/2012 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	07/15/2013 12:00:00 AM	ADDRESS	34.05357	-118.40916	REPLACING EXISTING SWITCHGEARS WITH NEW EQUIPMENT LIKE TO LIKE (SAME RATINGS) DUE TO WATER DAMAGE.  REPLACE THE 2,000AMP PULL SECTION, ONE 1,200 AMP AND ONE 600 AMP SECTIONS. NO NEW LOAD ADDED. ALL THE UNIT FEEDERS AND UNIT PANELS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55205	10041-20000-19277	11513 N ORCAS AVE	91342	2	213B173   240	2529025028	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2010 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	34.27955	-118.36927	New ground mounted 13.6kw P.V. system for single family dwelling.  EPC for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55206	18041-20003-17332	6927 N REMMET AVE Unit A	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	08/02/2018 Changes to an approved set of plans. Plans updated to match revised service configuration.Note: $0.00 plan review fee due CA Senate Bill 1222 07/23/2018 Revision to approved set of plans.  Change of inverter from ABB-PVI-3.6-OUTD-S-US-Z-A to ABB UNO-DM-3.3-TL-PLUS-US-SZ-RA.(((Plan check for a PV2 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (15) modules. Service size is 400 Amps.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55207	14041-20003-07472	7727 W FORSYTHE ST	91042	7	208-5A195 154	2557001030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.26607	-118.30118	$0 PLAN CHECK FEE DUE TO SENATE BILL 1222 FROM 2012((CHANGES TO APPROVED SET OF PLANS. CHANGES IDENTIFIED BY CLOUDED DELTA 3PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55208	14041-10001-35637	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	33.97902	-118.43558	Plan check for Title 24 for office TI in 6-story commercial office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55209	14041-20000-35542	1424 S BENTLEY AVE	90025	5	129B149    30	4324016031	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.05133	-118.44604	PC FOR FIRE ALARM SYSTEM. 39 DEVICES. CONTROL PANEL. 8 UNIT APARMENT. 4 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55210	14041-20000-29074	8406 N NOBLE AVE	91343	6	192B145   317	2653025009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Expired	11/14/2016 12:00:00 AM	ADDRESS	34.22306	-118.46099	PV1Using standard plan. Install roof-mounted solar array on SFD. Interconnect with MSP. System size: 6.8kW. Two inverters. Ungrounded system. 31 255W pv modules across 3 strings. Using 300W power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55211	19041-10000-20006	2600 S VERMONT AVE	90007	8	123B197   900	5055005033	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Issued	07/12/2019 12:00:00 AM	ADDRESS	34.03252	-118.29135	PC for outdoor T24 to an exisitng Ralphs, total affected area is 88,581 sqft. Scope of work includes replacement of existing fixtures with exisitng wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55212	17041-10001-14285	1501 N SUMMITRIDGE DR	90210	5	147B157   193	4355005039	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.09868	-118.41997	REVISED SINGLE LINE DIAGRAM TO SHOW THAT ATS IS RATED 400A  AND PANEL E IS RATED 400A WITH 225A MAIN CB. (((((((Plan check for power.  Remodel and addition to single family dwelling.  New 800 amp 208/120 volt service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55213	14041-10000-35143	1286 W 36TH ST APT #1	90007	8	120B197   964	5040007019	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			Reviewed by Supervisor	12/31/2014 12:00:00 AM	ADDRESS	34.02268	-118.29705	PV1, INSTALL 4.08 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: YINGLI YL255P-29b(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55214	11041-10000-12756	7301 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	07/11/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of 3 elevator unit in ADMIN at LAX. East Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55215	10041-10000-03159	9200 N GLENOAKS BLVD	91352	6	198B173   111	2408001003	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Public Safety Only			02/23/2010 12:00:00 AM			PC Approved	02/23/2010 12:00:00 AM	ADDRESS	34.2363	-118.37296	CHANGES TO ORIG APPROVED PLANS # 10041-10000-00145.  fire alarm system for office building 1 and 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55216	13041-20000-28085	21700 W OXNARD ST SUITE 680	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	10/09/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.17901	-118.60179	PC FOR T24 ENERGY ONLY. OFFICES. 1822SQ FT. LOW ADDITIONAL LOAD. WORK DONE IN SUITE 680.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55217	17041-20000-34516	24052 W BESSEMER ST	91367	3	177B089   433	2045006014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.18133	-118.65127	Plan check for AC coupled battery backup system for SFD (w/existing solar on site).(1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55218	19041-10000-04472	2424 S SAN PEDRO ST	90011	9	120A209   253	5131023024	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.02255	-118.26046	PLAN CHECK FOR TITLE 24 ONLY FOR - PROPOSED RETAIL ADDITION TO (E) TAKE-OUT RESTAURANT - TOTAL AFFECTED AREA = 761 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55219	18041-10000-39173	6067 W WILSHIRE BLVD 5TH FLR	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	02/01/2021 12:00:00 AM	ADDRESS	34.0631	-118.36086	FULL PLAN CHECK FOR POWER AND ENERGEY, TI OF AN EXISTING SHELL SPACE FOR A COMMERCIAL KITCHEN AT MUSEUMS 5TH FLOOR DINING HALL; INSTALL (2) 45kVA TRANSFORMERS, (2) PANELBOARDS, POWER AND LIGHTING. TOTAL AREA 1,450 SQ.FT(B# 18016-10000-33090)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55220	17041-10000-41466	601 W 5TH ST 5th Floor	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.05049	-118.25386	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING OFFICE BUILDING ON THE 5TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 12816 SQ. FT. B#17016-10000-32292	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55221	12041-10001-28467	9160 N SEPULVEDA BLVD	91343	7	198B145   317	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM			PC Approved	03/01/2013 12:00:00 AM	ADDRESS	34.23735	-118.46731	applicant brought in set of plans to be re-plan checked because the contractor lost the set of plansTUTTI FRUTTI YOGURT SHOPTenant improvement and change of use from beauty salon to take-out restaurant, including interior, non-structural remodel. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55222	18041-10000-40691	11866 RICASOLI WAY	91326	12	216B109   122	2701078036	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	PIN	34.28856498	-118.58424273	PLAN CHECK FOR ROOF MOUNTED 7.68kw AC PV SYSTEM ON SFD. SCOPE INCLUDE 24 MODULES SUNPOWER 360W-AC MODULE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55223	15041-20000-11117	540 S KINGSLEY DR	90020	10	135B193   794	5503024004	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			04/14/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.06422	-118.30266	Plan check for new fire alarm system (New appartment 35 units 5 story high). Total fire alarm devices: 133 devices and 4 fire alarm panels. Submit back room b/c it'll take more than 1 hr	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55224	15041-10005-27170	426 E 58TH ST	90011	9	108B205  1058	5101006006	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	33.98972	-118.26645	Changes to approved se of plans. Delta 8 changes. ((((CHANGES TO APPROVED SET OF PLANS. RECONNECTING 2 EXISTING PANELS TO NEW DISTRIBUTION SYSTEM. CHANGES NOTED DELTA 7 ON PLANS. permit issued for the reconnections))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55225	14041-10000-11929	3238 N HURON ST	90065	1	142-5A221  17	5446009013	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.08671	-118.22003	PV1 2.55KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(10)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55226	14041-20000-25798	1011 S FIGUEROA ST SUITE B101	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.04476	-118.26452	TI TO AN EXISTING RESTAURANT.  ADDING LIGHTS AND NEW BRANCH CIRCUITS.  USING EXISTING PANELBOARDS.  1655 SQFT. suite b101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55227	17041-10001-41639	8643-8645 N DARBY AVE	91325	12	195B125   941	2786004009	P-1VL, [Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.22762	-118.53401	This is plan check only, changes to approved set per field installation.<<<Power plan check only for a service upgrade of 800 Amp, 120/240V consists of (2) 400 Amp meter section for (2) building sharing a common wall. Scope only consists of 800A service with (2) 400A MSP, and (6) 200A panelboards. All loads and its circuitry are not part of this scope of work.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55228	14041-10000-09749	1101 S HARVARD BLVD	90006	10	129B193   713	5080021017	R3-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Apartment			04/14/2014 12:00:00 AM			Corrections Issued	05/08/2014 12:00:00 AM	ADDRESS	34.05066	-118.30443	plan check for power and energy. not methane. 10 typical units typical across 4 story. NEW 40 UNIT APARTMENT BUILDING WITH AFFORDABLE HOUSING INCENTIVE (BLDG# 07010-10-05432).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55229	17041-10000-27866	1308 S SOTO ST	90023	14	121-5A221 193	5170018015	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.10	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.02595	-118.21948	TITLE 24 PLAN CHECK FOR BANCK OF AMERICA PARKING LOT. SCOPE INCLUDES CHANGING AND ADDING OUTDOOR LIGHTING. TOTAL AFFECTED AREA = 23892 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55230	14041-20000-33272	24629 W STONEGATE DR	91304	12	186B089   117	2017028049	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Expired	12/27/2016 12:00:00 AM	ADDRESS	34.20924	-118.65717	PV1 SFD. TOTAL SYSTEM SIZE 7.5KW AC USING STRANSFORMERLESS INVERTER. USING STANDARD PLAN. TOTAL OF 40 MODULES. 4 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55231	15041-10000-31563	921 S CROCKER ST STE C-11	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (RETAIL SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 990 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55232	12041-10000-05412	351 E SUNSET AVE 1-6	90291	11	109-5A143 577	4286006036	[T][Q]CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			03/09/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	33.9959	-118.474	New fire alarm system for 6 unit condominium.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55233	15041-10000-07604	1550 W 8TH ST	90017	1	130-5A205 151	5142018001	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.05213	-118.27207	NEW 4 STORY COMMERCIAL OFFICE BUILDING, 600AMPS SERVICE, PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55234	19041-10000-12453	20450 W LASSEN ST	91311	12	201B109   131	2748006030	C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	10/19/2021 12:00:00 AM	ADDRESS	34.24983	-118.57925	PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES NEW 800AMPS SERVICE,120/208 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 1527 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55235	18041-10003-39776	21019 W ELKWOOD ST	91304	3	189B105   388	2109015024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.21286	-118.5915	"DELTA ""1"" Changes to approved plans. Installing a new Load Center.<<<<New roof-mounted 4.96KW solar PV system with 16 PV Panels on a single family home.Plan Check Only. Permit Number: 18041-90000-39776>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55236	17041-10000-23766	6850 N SEPULVEDA BLVD	91405	6	183B145   632	2220020012	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.19538	-118.46594	T24 plan check to remove existing 13 fixtures and replace with new LED fixtures. total affected area 36575 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55237	12041-10000-06221	940 N WESTERN AVE #B	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM			PC Approved	04/19/2012 12:00:00 AM	ADDRESS	33.75105	-118.30881	New addition to an existing retail space.  Less than 400A of new load.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Unit #B (Ross)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55238	16041-20000-02450	7888 N VAN NUYS BLVD 1-2	91402	6	189B149   639	2212028015	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	34.21514	-118.44612	Revisions to approved set.  Reduction of main service disconnect to 400A. Delta 3 revisions only.  Original issued permit under 14041-20000-35962(((Supplemental change to an approved set of plan. Adding lighting fixtures A/AE, A1/A1E. PC for T-24 only. Total area: 11,096sq. ft. Permit Under 14041-20000-35962. )))  (((Plan check for power and energy. CHG OF USE FROM TRADE SCHOOL TO RETAIL (Pet's Mart) ALSO EQUIPMENT PLATFORMS @ ROOF. Existing service, pull section, and service disconnect, all other electrical work is new.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55239	19041-10000-22742	5856 W MANCHESTER AVE	90045	11	096B169   560	4125009012	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.95971	-118.3847	Replacing Existing HID Fixtures with new LED Fixtures (Outdoor).Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55240	16041-10000-18194	1840 S CENTURY PARK EAST 8TH FLOOR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	PC for T-24 only.  TI to an (E) space 8th floor.  Install new lightings and controlled receptacles. New connected loads < 400A.  Total area: 9,291 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55241	17041-10000-31320	8500 W BEVERLY BLVD 113	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	RESTAURANT TI. PC FOR POWER AND ENERGY. NEW DISTRIBUTION AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55242	14041-10000-25396	328 S LA BREA AVE	90036	4	135B181   261	5507008021	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.06807	-118.34383	SERVICE UPGRADE TO 800AMPS FOR EXISTING COMMERCIAL BUILDING. SCOPE OF WORK COVERS SWITCHBOARD AND MAIN BREAKERS (FULLY RATED) ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55243	11041-10000-16390	2500 S NAVY WAY	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM			PC in Progress	09/19/2011 12:00:00 AM	ADDRESS	33.73363	-118.2408	"INSTALL ONE NEW CONTAINER CRANE (#18) AT BERTH 406 IN PIER 400 IN ""CALIFORNIA UNITED TERMINAL""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55244	17041-10000-26629	8400 N BALBOA BLVD	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.22376	-118.50243	PC FOR FA SYSTEM. TOTAL OF 63 DEVICES AND MAIN PANEL. USING POWER BOOSTER PANEL. LA FITNESS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55245	17041-10000-38355	17144 W LORNE ST	91406	6	189B133   215	2204007009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.21712	-118.50715	Add a new Tesla Battery System to an existing PV system in a single family home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55246	18041-10000-22916	1801 S CENTURY PARK EAST #800	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Issued	06/20/2018 12:00:00 AM	ADDRESS	34.06201	-118.41537	PC FOR OFFICE TI  IN A HIGHRISE BUILDING ON THE 8TH FLOOR FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 6000SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55247	18041-10000-37989	10169 N TUJUNGA CANYON BLVD	91042	7	202-5A199 135	2568011001	M1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.25021	-118.28929	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55248	17041-10001-29905	11327 N BERTRAND AVE	91344	12	213B125   614	2715019027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South	YES	1112.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM			Verifications in Progress	10/06/2017 12:00:00 AM	ADDRESS	34.27666	-118.52531	expedite feesPC FOR ROOF TILED PV SYSTEM. USING 692 MODULESS (TILES) AND 2 INVERTERS SYSTEM SIZE 15.2KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55249	15041-10006-33053	9254 N WINNETKA AVE BLDG C	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM			PC Approved	08/06/2019 12:00:00 AM	ADDRESS	34.23884	-118.57087	08/06/19CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF STAIRWELL LIGHTING TO INCLUDE NORMAL AND EMERGENCY LIGHTING, ALSO THE CONNECTION OF CORRIDOR SCONCE LIGHTING TO OCCUPANCY SENSOR. NOTE CHANGES ON CLOUDED AREA. ___________________________________________DELTA 25. 26, 27, & 31 CHANGES TO APPROVED PLANS. REPLACING ONE AIR CONDITIONER TO TWO AC's IN EACH UNIT, ADDING NEW CIRCUITS TO UNIT PANELS, CHANGES TO LIGHTNG IN THE COMMON AREAS AND CHANGES TO FEEDERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55250	13041-10002-27139	20314 W VIA MANTUA	91326	12	219B113   238	2701059030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Expired	12/01/2015 12:00:00 AM	ADDRESS	34.29836	-118.57602	][][]  $0 permit fee is due to the 2012 Senate Bill No. 1222. CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGES IS FOR MODULE RELOCATION AND CHANGING OF INVERTER FROM POWER-ONE PVI-5000 TO SOLAREDGE #SE6000A][][]ORIGINAL WORK DESCRIPTION:::PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 6.25 kW. TRANSFORMERLESS INVERTER. 2 STORY.(25) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-5000-OUTD-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55251	15041-10003-41798	7007 W ROMAINE ST	90038	4	144B181   605	5532030012	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.08901	-118.34188	*****SEE COMMENTS*****PC FOR CHANGES TO APPROVED SET UNDER DELTA 9 ONLY. SCOPE INCLUDES NEW 57KW AC UNITS ON THE 5TH AND 6TH DISTRIBUTION BOARDS (DB5F, DB6F) WITH ADDITIONAL SUPPORT EQUIPEMNET (EFS AND PUMPS). ADDITIONALLY, SOME CIRCUITRY AND EQUIPMENT AS MARKED ON THE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55252	16041-10000-04758	8951 N TAMPA AVE	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.23298	-118.55405	T-24, TI TO AN (E) RETAIL STORE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. F.T 5714	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55253	16041-10000-28871	3820 W SANTA ROSALIA DR	90008	10	114B181   113	5032018006	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.01087	-118.34043	Plan check for T-24 only. Remove indoor & outdoor HID fixtures and replace with new LED fixture.  Total area: 15,768 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55254	15041-20000-00478	700 S FLOWER ST # 2950	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to existing office building. Title 24 plan check for energy only. Adding lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55255	17041-10000-18076	2851 S OVERLAND AVE	90064	5	123B161  1309	4255011017	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.03405	-118.4192	REPLACE HID FIXTURES FOR MORE ENERGY EFFICIENT LED TYPE. REDUCE IN WATTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55256	19041-20001-23261	20869 W LASSEN ST	91311	12	201B109    90	2741002005	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM			PC Approved	12/13/2019 12:00:00 AM	ADDRESS	34.25013	-118.58824	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGE ONLY, CHANGE TO T24 SHEET, CHANGE TO REQUIRED DOCUMENT INDICATORS AND MANDATORY DEMAND RESPONSE CONTROL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55257	17041-30000-03889	11100 W SANTA MONICA BLVD Suite 110	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.04726	-118.44465	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,377 sq. ft.Note: Building permit has been pulled under 16016-10000-30491	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55258	13041-20000-16015	1006 N COLE AVE #3100	90038	4	144B185   930	5533015018	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.08915	-118.32971	Change to lighting only in an existing single story office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55259	18041-20000-07744	7368 N CARTWRIGHT AVE	91352	2	186B177   399	2410012024	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Issued	03/02/2018 12:00:00 AM	ADDRESS	34.20461	-118.36364	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (12) modules, (2) load center, and (1) Tesla PowerWall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55260	14041-20000-27467	12615 N EL ORO WAY	91344	12	219B133   158	2608005006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.29955	-118.5068	PV1.  Install 4.86 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55261	17041-10000-01079	19701 S HAMILTON AVE	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Issued	01/17/2017 12:00:00 AM	ADDRESS	33.85221	-118.28625	PC for energy only to a 2-story office building. Office remodel, adding new lighting and receptacles on second floor only. Total area: 2350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55262	14041-10000-29897	973-977 E ELKHART PL BLDG 45	90291	11	111B145   756	4243003035	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			10/28/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	33.99997	-118.46096	removing existing wall heaters from 28 units and replacing with split system heat pump. also addition of site lighting to existing house panel, revise existing lighting in the kitchens.  <<Multiple addresses in this building 934 - 936 Lake St & 1002 - 1012 Frederick St & 973 - 977 E. Elkheart >>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55263	12041-10001-23021	4301 W 3RD ST	90004	4	135B193   200	5517007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10, 2118.01	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	PIN	34.06916769	-118.30825671	[][][]CHANGES MADE TO A SET OF APROVED PLANS; THE ADDITION OF EF-7 AND POWER FOR DOOR STRIKES, REMOVED AC UNIT AND REMOVED ONE EV CHARGER; NOT INCLUDING LOW VOLTAGE AND CAMERAS ADDITIONS IN THE SCOPE OF PLAN CHECK , ALL CHANGES ARE CLOUDED ON PLANS, PL, 7-26-13[][][][]NEW CONSTRUCTION FOR A MULTI LEVEL PARKING GARAGE. EPC IS FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55264	12041-10000-30966	4477 W BEVERLY BLVD	90004	4	138B193   476	5521029020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10, 2114.10	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Expired	11/13/2013 12:00:00 AM	ADDRESS	34.07637	-118.30636	CHANGE OF USE FROM (E) COMMERCIAL SHOP  TO (N) LAUNDROMAT. PLAN CHECK IS FOR T24 AND REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55265	19041-10000-12844	1700 N NAUD ST	90012	1	136-5A219 129	5409002021	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM			PC Info Complete	05/17/2019 12:00:00 AM	ADDRESS	34.06865	-118.22638	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM WAREHOUSE TO PHOTOGRAPHY STUDIO.  SCOPE OF WORK INCLUDES, NEW PANELS, AND CIRCUITS. TOTAL SQ. FT. 9843.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55266	12041-20000-05590	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	(T)[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Closed	10/04/2013 12:00:00 AM	ADDRESS	34.09787	-118.31961	1200 A temp.construction service	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55267	10041-10001-03484	13401 W BROMWICH ST	91331	6	198B157   525	2625021010	RA-1, RS-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2010 12:00:00 AM			PC Approved	01/03/2011 12:00:00 AM	ADDRESS	34.23872	-118.42646	ROOF MOUNTED SOLAR VOLTAIC SYSTEM.  AN ORIGINAL PERMIT WAS ISSUED FOR THIS PROJECT. THIS REVIEW IS FOR PLAN CHK ONLY AS PERMIT WAS OBTAINED ON 10041-10000-03484	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55268	13041-10000-25746	2303 S FIGUEROA WAY	90007	1	123A203   162	5124028010	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.03049	-118.27509	TITLE 24 PLAN CHECK ONLY. TENANT IMPROVEMENT ON CHARTER SCHOOL. 2 STORY BUILDING. WORK ON FIRST FLOOR ( EXPANSION OF KITCHEN AREA). 685 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55269	17041-10000-18115	8401 W MELROSE PL	90069	5	141B173   440	5528002029	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.08378	-118.37333	Title 24 plan check.  T.I. for retail tenant in existing Nordstrom building.  One new 150 amp subpanel to feed new lighting and receptacles.  Total area = 3,617 sq. ft.       Building permit #17016-30000-14328	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55270	17041-20000-22262	584 S MATEO ST	90013	14	126A217   105	5164007001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.03898	-118.23266	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55271	17041-20001-03787	14347 W BURTON ST	91402	6	192B149   438	2212004018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM			PC Approved	02/13/2017 12:00:00 AM	ADDRESS	34.22074	-118.44626	expeditepv1addition to an existing pv system.  install roof mounted pv system sized 3kw interconnected wtih msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55272	09041-10002-19509	7660 W SUNSET BLVD	90046	4	147B177  1009	5550030001	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM			PC Approved	07/15/2010 12:00:00 AM	ADDRESS	34.09787	-118.3566	REVISIONS TO APPROVED SET OF PLANS-RELOCATED THE WATER FRM THE INSIDE TO THE ROOF; CHANGE TYPE G LUMINAIRE TO A SINGLE LIGHTING FIXTURE AND RELOCTED THE MAINSWBD TO A NEARBY LOCATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55273	11041-20001-21605	104 S ROBERTSON BLVD	90048	5	138B169   373	4334005002	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM			PC Approved	10/25/2011 12:00:00 AM	ADDRESS	34.07505	-118.3836	"Modification to an approved set of plans.  The modifications are that the previous ""existing"" light fixtures will now be replaced with new light fixtures.  Plan check is for energy only.  <<<<<TI - retail P/C is for Energy and emergency lighting.>>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55274	16041-20000-15473	14144 W VENTURA BLVD #200	91423	4	165B153   434	2266003092	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.14958	-118.44166	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 2ND FLOOR. 2380 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55275	17041-10000-36854	7315 N LANKERSHIM BLVD	91605	2	186B169   863	2317018038	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			Corrections Issued	10/13/2017 12:00:00 AM	ADDRESS	34.20331	-118.38798	PC FOR FA SYSTEM IN A 2 STORY BUILDING FOR THE FIRST FLOOR SPACE. SCOPE INCLUDES NEW PANEL AND  22 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55276	17041-10000-11759	5700 N CANOGA AVE 100	91367	3	174B105    83	2149019015	CO(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Info Complete	04/26/2017 12:00:00 AM	ADDRESS	34.17365	-118.59715	T-24. INTERIOR BANK TI. SCOPE OF WORK INCLUDES NEW LIGHTING IN A SMALL PORTION OF THE SPACE AND NEW RECEPTACLES. TOTAL SQ. FT. 1802Permit issuer to verify inspections feesya	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55277	17041-10001-40168	825 S HILL ST 1st floor	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.04392	-118.25657	PC FOR CHANGES TO APPROVED SET FOR  First tenant in office space full plan check.SCOPE OF CHANGES INCLUDES ADDITIONAL SQ.FT OF AROUND 50SQ.FT WITH NEW CIRCUITS AND CHANGES TO LIGHTING FIXTURES. B# 17016-10001-33330	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55278	14041-10000-06253	200 N AVENUE 64	90042	14	154-5A233 385	5493016013	[Q]C4-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.11564	-118.18062	PV2, INSTALL 2.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL.(9) MICRO INVERTERS: HANWHA HSL60P6-PB-0-240(9) MODULES: ENPHASE ENEERGY MICRO INVERTER M215-60-240V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55279	16041-10000-32223	407 W 7TH ST	90731	15	015B201   797	7455006***	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Apartment			09/12/2016 12:00:00 AM			Corrections Issued	09/12/2016 12:00:00 AM	ADDRESS	33.73766	-118.28583	T-24, PC for energy only. tenant improvement. Change of use of a vacant commercial space to a recreational space/Gymnasium. Scope includes new lights and receptacles. Total affected area is 2125 Sq. ft. Note: Permit is paid under PCIS#16041-40000-15442 and 16041-40001-15442	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55280	18041-10000-00342	10211 S AVALON BLVD	90003	8	091-5A207 261	6063012023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	33.94339	-118.26535	INSIDE A SUPERIOR GROCERY STORE, ENCLOSING A SPACE FOR  A WELLS FARGO BANKING/OFFICEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55281	15041-20000-31720	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Expired	11/14/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is an existing mall. Project scope is outdoor parking lot lighting. Total lighting area = 1,140,250 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55282	14041-10000-14119	828 N KENMORE AVE	90029	13	141B197    22	5538014009	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.08673	-118.29688	PV1 4.59KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(18)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55283	10041-20000-09132	3501 S TROUSDALE PKWY	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	ADDRESS	34.02194	-118.28455	Plan check T-24 Energy (general/emergency) lighting for USC Mark Taper Hall of Humanities Classroom #221	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55284	19041-10000-39252	23064 W ENADIA WAY	91307	12	183B097   291	2026028020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.19871	-118.6296	[E-PLAN] PV1. New Roof-mounted solar system installation consist of 42 modules (Panasonic 330) with 42 microinverters ( IQ7X-96). System size is 13.86 kW DCand 13.44 kW AC.Connected to a new 200A service. Panel upgrade to be permitted separately	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55285	16041-10000-29267	6526 N GROSS AVE	91307	12	180B093   569	2036023023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.18906	-118.64026	ROOF TOP SOLARPV1 SFD TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 40 MODULES IN TOTAL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55286	15041-10000-23391	1100 S WESTWOOD BLVD	90024	5	132B153   178	4363022004	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.0605	-118.44507	TI ON EXISTING AT&T RETAIL STORE. SCOPE OF WORK INCLUDES NEW LIGHTING.  TOTAL AREA = 7675 SQ. FT. PC FOR ENERGY ONLY, TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55287	15041-20000-10573	3338 E SCARBORO ST	90065	1	148-5A217  46	5464028008	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.10301	-118.22874	PC FOR 6KW AC PV SYSTEM. USING 2 INVERTERS. TOTAL OF 23 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55288	13041-10000-07092	401 N WESTERN AVE	90004	4	138B193    16	5522019012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1924.20	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.07856	-118.30934	13041-10000-07092pc for energy only. 2 NEW 15' POLE LIGHT 435  W PSMH for existing parking lot. less than 400 A per applicant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55289	18041-10003-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2018 12:00:00 AM			PC Approved	05/07/2018 12:00:00 AM	ADDRESS	34.26056	-118.35206	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REMOVING A TESLA BATTERY AND RECONFIGUING THE SINGLE LINE DIAGRAM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55290	16041-10000-44575	11674 W CANTARA ST	91605	6	192B169   556	2311005002	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.21924	-118.38725	PC FOR ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA7,475 SQ FT. (OUTDOOR+ INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55291	12041-20000-17843	2188 W STRATFORD CIR	90049	5	150B141    85	4377048019	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.1094	-118.47493	New single family house with new 800A serivce.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55292	12041-10001-14319	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	(T)[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Public Safety Only			10/16/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.09787	-118.31961	delta 5 changes reducing the number of FA devices that were permitted; devices have similar manufacturerJob was approved by francis on counter, plan check only.  this job should have been done at counter....NabilNEW FIRE WARNING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55293	14041-20000-30932	4740 N VIVIANA DR	91356	3	168B117   382	2178018018	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.15584	-118.55423	PV1 ROOFMOUNTED SOLAR SYSTEM. NON STANDARD CENTRAL INVERTER. SYSTEM SIZE 10260W DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55294	14041-20001-14380	800 W WILSHIRE BLVD #102	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.0493	-118.25841	SUPPLEMENTAL PERMIT TO REMOVE AND ADD LIGHTING FIXTURES.ORIGINAL PERMIT UNDER 14041-20000-14380.TI for (E) restaurant space in existing commercial highrise building.  Title 24 plan check for changes to lighting system.  Newly connected load below 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55295	12041-10002-30783	"12746 W JEFFERSON BLVD ""1"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM			PC Approved	01/08/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Change to approved set by down size the OCPD  for elevators and escalators from approved set to match up with installation on the field. Requested by inspector; all change is under delta A only.(((Change to approved set, changes include adding circuits, removing and adding lighting, and relocate some electrical devices.(((Plan check power and energy for Building 1. One story retail shell on top of common subterranean parking with Building 2, 3, and 4. Service supplying Building 1 and Building 2. Site located in methane zone. Modification to separate fire alarm system has been filed.)))  )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55296	18041-20000-02620	245 N ALVARADO ST	90026	13	136-5A205 137	5157020104	R4-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.06907	-118.26912	Note: $0.00 permit fee due to CA Senate Bill 1222PLAN CHECK FOR PV ROOF MOUNTED SYSTEM FOR COMMERCIAL BUILDING. SYSTEM SIZE = 40KVA. SYSTEM CONSIST OF 2 CENTRAL INVERTERS (SOLAREDGE_SE20KUS) AND 150 MODULES WITH P320 POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55297	16041-10000-02850	15857 W STRATHERN ST	91406	6	189B141    30	2206005023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.21581	-118.47928	New FA system for a commercial site single story. Installing (1) new FA panel, (3) Communication panels, (4) control panels, (127) FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55298	14041-10000-21975	3785 W WILSHIRE BLVD # 36	90010	10	132B193    30	5503030903		Central				2118.02	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.06187	-118.30858	Title 24 plan check only.  Total area = 755 sq. ft.T.I. to existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55299	13041-20000-29082	333 S GRAND AVE 10th floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	Change to lighting on the 10th floor of an existing office building.  Load is decreased per applicant, All existing circuits.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55300	10041-10000-00540	404 W PACIFIC COAST HWY	90744	15	036B205  1154	7420004030	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	01/19/2011 12:00:00 AM	ADDRESS	33.79073	-118.26716	CHANGE OF USE FROM EXISTING DONUT SHOP TO STORAGE AREA TO EXPAND EXISTING ADJACENT RETAIL SPACE.  T-24 AND EMERGNECY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55301	10041-10000-07697	145 S ROBERTSON BLVD	90048	5	138B169   524	4334001022	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	05/25/2010 12:00:00 AM	ADDRESS	34.07394	-118.38392	ALTERATIONS IN AN EXISTING RESTAURANT- NEW LUMINAIRES, EQUIPMENT AND RECEPTACLESAND NEW FACADE LUMINAIRES.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55302	19041-10000-09719	601 W 5TH ST 9th Flr	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.05049	-118.25386	TI TO 9TH FLOOR. NEW LIGHTING THROUGHOUT. T-24 ENERGY ONLY. BUILDING PERMIT: 19016-10000-01556	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55303	11041-10000-06658	3500 W WILSHIRE BLVD	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Expired	05/21/2013 12:00:00 AM	ADDRESS	34.06157	-118.30077	T.I. FOR AN EXISTING RESTAURANT.  T-24 OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55304	17041-20000-06458	601 W 5TH ST 2nd, 3rd &-7th Floors	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for energy only. New lighting (incl. emergency) in corridors and restrooms on 2nd, 3rd, and 7th floors of existing high rise building. 5,578sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55305	18041-20000-11034	1374 W 35TH ST	90007	8	120B197   735	5040004025	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.02449	-118.29977	Plan check for power and energy. Project site is an existing commercial building.  Change of use from middle school to elementary/tenant improvement. Total lighting area = 2,600 sq. ft.Note: Building application has been generated under 18016-10000-08891	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55306	11041-10000-08443	2930 E WHITTIER BLVD	90023	14	123A223   248	5189004040	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Expired	05/21/2013 12:00:00 AM	ADDRESS	34.03069	-118.20803	NEW FIRE ALARM IN EXISTING COMMERCIAL STORAGE BUILDING.  OTC PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55307	18041-10001-05459	3863 S COOLIDGE AVE	90066	11	114B157  1033	4214013025	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM			PC Approved	02/13/2018 12:00:00 AM	ADDRESS	34.00755	-118.42279	04/06/2018 PC ONLY FOR CHANGES TO AN APPROVED SET.  CHANGES INCLUDE RELOCATING THE INVERTER, AC DISCONNECT AND THE MAIN SERVICE PANEL. CHANGES ARE UNDER DELTA A. CHANGES ARE ON PV-1A, PV-2, PV-4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55308	12041-10000-12382	221 S GRAND AVE	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.05419	-118.2505	New fire alarm system for Broad Museum.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55309	15041-10000-24281	5919 W 3RD ST STE 1A	90036	5	135B181    83	5512019012	C1-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.06973	-118.34927	TI ON EXISTING COMMERICIAL (DENTAL OFFICE) BUILDING. PC FOR ENERGY AND POWER. SCOPE INCLUDES 1 NEW PANEL.  TOTAL AREA = 1357 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55310	12041-20000-01927	601 S FIGUEROA ST #2790	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Info Complete	01/26/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I. to high rise building on 27th floor.  Install general/emergency light.  Plan check for energy only.Note: Permit issued under 12041-20000-05995	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55311	18041-10001-27721	7662 W MELROSE AVE	90046	5	141B177   639	5527023025	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	34.08351	-118.35688	Changes to an approved set of plans. Scope of work includes revision of emergency lighting and fixture schedule. Note changes on clouded areas, delta 1. Plan check only. _______________________________T-24, PC FOR ENERGY ONLY. CHANGE OF USE OF (E) OFFICE TENANT SPACE TO COFFEE SHOP. SCOPE INCLUDES NEW 125A PANEL, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 971 SQ. FT. B#18016-10000-16819	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55312	10041-10000-08103	1640 S SEPULVEDA BLVD #100	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood			2655.20	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	05/03/2010 12:00:00 AM		Permit Finaled	06/14/2010 12:00:00 AM	ADDRESS	34.04838	-118.44468	T.I. for office space in existing building.  PC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55313	12041-20000-11301	707 W WILSHIRE BLVD Unit 3650	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM			PC Approved	05/17/2012 12:00:00 AM	ADDRESS	34.04893	-118.2572	Remodel. Plan check for energy and emergency lighting. Commercial high-rise, 36th floor. 2530 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55314	10041-10000-24298	5939 W HOLLYWOOD BLVD	90028	13	148-5A191  72	5545003028	C4-1-SN, R4-2	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Public Safety Only			12/07/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Expired	01/24/2013 12:00:00 AM	ADDRESS	34.10186	-118.31926	REPLACEMENT OF FA PANEL FOR A FA SYSTEM THAT MONITORS A SPRINKLER SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55315	19041-10000-40472	415 S LA BREA AVE	90036	4	135B181   428	5508006029	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.06635	-118.34436	Full plan check for an existing space. Scope include new panels, circuits, lighting and equipment with a total lighting area of 61,173-SQ FT. Existing service 2000-Amp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55316	15041-20000-18901	10100 W SANTA MONICA BLVD 1st  Floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for Title 24 only. Pro ject site is 1st floor of an existing highrise commercial building. Project scope T.I. Total indoor area: 4.493 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55317	19041-20000-07064	9218 N ENCINO AVE	91325	12	198B129   300	2766011006	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	03/26/2021 12:00:00 AM	ADDRESS	34.23841	-118.51548	Plan check for a PV1 roof-mounted PV system. System size is 16.2 kWdc/13.77 kWac-CEC and consists of (2) 7.6 kWac rated inverters, (45) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55318	17041-10000-34887	10730 W PICO BLVD	90064	5	126B157   760	4255028008	C2-1VL, PB-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/22/2021 12:00:00 AM	ADDRESS	34.04128	-118.42564	FULL PLAN CHECK FOR SHELL IMPROVEMENTS TO EXISTING RETAIL BUILDING FOR CONVERSION TO MIXED USED OFFICE/RETAIL. THERE ARE (2) 4000A SERVICES AT 480/277V, 3PH, 4W, TOTAL AREA PER SOW IS 255,022 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55319	15041-10002-35360	7051 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM			PC Approved	03/10/2016 12:00:00 AM	ADDRESS	33.94265	-118.41882	3/10/2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 7 ONLY. CHANGES INCLUDE PANEL LP4 RATING TO 225AMPS NO NEW LOAD. CHANGES ON PAGES E301, E404, AND E405. (((02/19/2016 CHANGES TO AN APPROVES SET OF PLANS, CHANGES INCLUDE THE DETAILS OF GROUNDING METHODS, ADDITION OF METHANE PULL SECTION TO SWITHGEAR 'A' AND THE CONFIGURATION OF PANEL LP4.  (((PC for power, Temporary medium voltage, 4.16KV, from LAWA power trailor #1 to feed Switchgear A and Panel LP4. Switchgear A has three feeders feeding  A-1, A-2 and A-3.  A-1 and A-2 have existing loads and A-3 is for future construction load. Panel LP4 is for power shelter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55320	13041-20000-04035	18632 W DELANO ST	91335	3	177B121   830	2127015103	(Q)RE11-1-K	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	34.18279	-118.5397	Photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55321	17041-20001-30213	11515 W PICO BLVD	90064	11	123B153   462	4260026001	[Q]CM-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.03321	-118.44302	8.31.207 - Plan check for energy only. TI - change of use from hair salon to office. New lighting - 2,050sqft.Permit fees pulled under parent application #17041-90000-30213.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55322	19041-20000-41035	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55323	14041-10000-34612	1943 N VINE ST	90068	4	150A187   101	5576019065	R2-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.1065	-118.32681	PV1.  Install 9.483 kW roof-mounted, utility-interactive PV system.  Array and inverter proposed to be installed on roof of 1943 S. Vine St.  Point of interconnection to be at service point of 1946 Vedanta Pl.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55324	19041-10000-42588	1417 W 187TH PL	90248	15	060B193   319	6108011012	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	33.86056	-118.3006	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.20KW. (13)AC MODULES- SUNPOWER SPR-A400-G-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55325	18041-20001-37697	4550 N NAGLE AVE	91423	4	168B157   900	2360020028	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM			PC Approved	10/07/2018 12:00:00 AM	ADDRESS	34.15323	-118.4235	Expedite per applicat requestPlan check for PV roof mounted system, system size: 11.5KW DC, 10.78KW AC with 35 PV Modules and 1 inverter(11.4kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55326	19041-20001-43999	2107 N WEST SILVER LAKE DR	90039	4	147A207    34	5439031025	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.09738	-118.26668	$0 fee per department error changes to work description.PV1. INSTALL 6.67 KW AC PV SYSTEM WITH (23) MODULES/OPTIMIZERS, (1) INVERTER (SE7600), AND (1) ENERGY STORAGE SYSTEM (5KW).INSPECTION FEE UNDER PERMIT NUMBER 19041-20000-43999	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55327	17041-30000-45502	2112 S BARRINGTON AVE Bldg E	90025	11	123B149   250	4260008012	C2-1, R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.03531	-118.44854	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,126 sq. ft.Note: Building application has been generated under 17016-30000-14384	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55328	13041-20000-21287	1000 W WILSHIRE BLVD 16TH FLR	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.05085	-118.26078	RENOVATION OF EXISTING OFFICE SPACE. NEW LIGHTING. TOTAL AREA 11470 SQ FT. WORK DONE ON 16TH FLOOR. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55329	16041-10000-17661	11726 W SAN VICENTE BLVD 150	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.05328	-118.46625	T-24, PC FOR ENERGY ONLY.TI TO AN (E) RESTAURANT. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND ONE 200A NEW PANEL. TOTAL AFFECTED AREA IS 1560 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55330	17041-10000-04124	4250 S GLENCOE AVE	90292	11	105B153     8	4230006036	[Q]CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	33.98761	-118.4405	RENOVATION TO AREAS IN EXISTING APARTMENT BUILDING. PC FOR T24 ENERGY ONLY. COMMON AREA REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55331	15041-10000-08564	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	AT TBIT TERMINAL-LEVELS 1THRU4, ALTERATIONS OF LIGHTING SYSTEM FOR SECURITY SCREENING AREA S AND CONVEYOR SYSTEMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55332	10041-10000-00772	4628 W HOLLYWOOD BLVD	90027	13	147B197   481	5542014009	C2-1	Central	Hollywood	East Hollywood		1913.00, 1953.00	Electrical	Electrical	Commercial			01/15/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	04/26/2010 12:00:00 AM	ADDRESS	34.09982	-118.29022	CONVERT TRAFFIC SCHOOL(OFFICE) SPACE TO JUICE BAR (covell)plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55333	14041-10000-17212	145 S SPRING ST 7th floor	90012	14	130-5A213  30	5149001003	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.05196	-118.24563	Title 24 energy for corridors in a high rise building. Existing offices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55334	18041-10001-06618	808 N LILLIAN WAY	90038	13	141B185   199	5533030010	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.08566	-118.32757	Plan Check for a lost of plans. Plan check for a new fire alarm sprinkler monitoring system. Scope includes new fire alarm panel and (10) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55335	11041-10000-02888	2000 S AVENUE OF THE STARS 12th floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	04/14/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	Ti in an office area of a highrise building. EPC is for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55336	18041-20001-33972	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM			PC Approved	09/19/2018 12:00:00 AM	ADDRESS	34.1937	-118.49152	09-17-2018 Changes to an approved set of plan, changes include update fault current calculation to existing panels. Changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55337	18041-10001-05281	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM			PC Approved	05/30/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET TO REFLECT INSTALLATION OF MEANWELL DRIVERS. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER APPLICATION. PC for T24 only for sign lighting. Installing new LED signs in food court area in LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55338	18041-10000-45303	11643 W SHELDON ST	91352	6	201B169   105	2537023014	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Reviewed by Supervisor	12/18/2018 12:00:00 AM	ADDRESS	34.24519	-118.386	NEW ROOFTOP MOUNTED 6.37 KW PV SYSTEM ON (E) COMMERCIAL BUILDING (21)MODULES ON ONE PORTION OF THE BUILDING AND (17) ON ANOTHER . THIS ONE INCLUDE THE (21) MODULES ACSYMO 10.0-3 INVERTER . SEE 18041-10000-45293 FOR CROSS REFERENCE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55339	17041-20000-42970	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.23541	-118.47521	Plan check for a PV2 roof-mounted PV system. System size is 56.95 kWac and consists of (4) inverters, (174) modules, and (1) load centers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55340	19041-10000-24167	2913 W EXPOSITION PL Units 1-5	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.02048	-118.32811	PC FOR FA ALARM SYSTEM FOR WATER FLOW MONITORING. 1 FACP AND 9 DEVICES.***BUILDING PERMIT 18010-10000-00126***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55341	09041-20002-22390	320 S BRISTOL AVE	90049	11	129B137   141	4405023005	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2011 12:00:00 AM			PC Info Complete	10/26/2011 12:00:00 AM	ADDRESS	34.05248	-118.48669	PLAN CHECK FOR DELTA 2 REVISION. NEW CKTS AND RELOCATED CKTS TO NEW PANEL 2EB ADDED. INTERLOCK DEVICE CONNECTED TO BE2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55342	10041-20000-12010	7325 N MEDICAL CENTER DR 202-204	91307	12	186B097   830	2021014040	(Q)CR-1VL, CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM			PC Approved	06/23/2010 12:00:00 AM	ADDRESS	34.20328	-118.62963	revision to approved plans energy plan check only and relocation of outlets.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55343	19041-10000-33840	9945 N WORNOM AVE	91040	7	201B181    69	2543033001	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Issued	10/01/2019 12:00:00 AM	ADDRESS	34.25083	-118.35211	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 6.0KVA PV1 SYSTEM CONSISTING OF 1 CENTRSAL INVERTER (SE6000H-US) WITH 18 MODULES USING P400 OPTIMIZERS AND ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55344	19041-20001-41784	1919 S PONTIUS AVE	90025	5	126B153   332	4323025014	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			PC Approved	02/07/2020 12:00:00 AM	ADDRESS	34.04362	-118.44177	EXPEDITE FEEPV3 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS 23.1 KW DC/20 KW AC CEC. SCOPE OF WORK CONSISTS OF (70) PV MODULES WITH OPTIMIZERS, (2) 9 KW CENTRAL INVERTERS, AND A 125A PV SUB PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55345	15041-20000-21693	15060 W VENTURA BLVD	91403	4	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.15287	-118.46147	Title 24 plan check only.  Total area = 4,567 sq. ft.  T.I. to existing low-rise commercial office space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55346	15041-20000-23446	550 S HOPE ST Suite 1600	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM			PC Approved	07/22/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	Title-24 plan check only.  Total area = 1,663 sq. ft.  T.I. to existing commercial office highrise space.  New lights and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55347	19041-20000-22178	22135 W ROSCOE BLVD LOT #16	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 16.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55348	12041-10002-31058	15154 W WEDDINGTON ST PV1	91411	2	172-5A147 168	2250003010	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.16715	-118.46373	((((CHANGES MADE TO ORIGINAL PLANS. ADDED 9 MORE MODULES AND IT IS A TRANSFORMERLESS SYSTEM))))))INSTALL ROOF MOUNTED SOLAR, INTERCONNECT MAIN SERVICE PANEL.(8.4KW) Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55349	19041-20000-34986	602 S WESTLAKE AVE	90057	1	133-5A205 317	5142001013	C2-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Apartment			09/04/2019 12:00:00 AM	07/24/2020 12:00:00 AM		Issued	07/24/2020 12:00:00 AM	ADDRESS	34.05869	-118.27365	NEW 2500 AMP 3PH 120/208V SERVICE. SCOPE OF WORK INCLUDES PANELS, EQUIPMENTS AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55350	18041-10000-16847	7545 W FOOTHILL BLVD	91042	7	204A197   298	2558029018	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.25385	-118.29673	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55351	13041-20000-29416	604 E ROSE AVE	90291	11	111B145   964	4240011047	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			Reviewed by Supervisor	10/28/2013 12:00:00 AM	ADDRESS	33.99915	-118.47166	PLAN CHECK FOR INSTALLATION OF OPTIONAL STANDBY GENERATOR IN CLINIC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55352	18041-20000-23162	1405 S WELLESLEY AVE	90025	11	126B145   822	4267032015	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	12/24/2020 12:00:00 AM	ADDRESS	34.03973	-118.46588	Plan check for power and energy for change of use from Home of the Age to Hotel mixed use existing building. Total area: 47739 sq ft. B#18016-1000004044	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55353	18041-10000-46698	1660 W RIVERSIDE DR	90031	13	144B213    13	5445001037	C2-1VL-RIO, P-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley			1972.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.09469	-118.24235	FULL PLAN CHECK FOR POWER AND ENEGY FOR - INTERIOR  TI OF COMMERCIAL OFFICE BUILDING, NEW STORAGE ROOM (ADDITION) NON HIGHRISE BUILDING - TOTAL CONNECTED LOAD >400A WITH 8542 SF OF AFFECTED AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55354	15041-20000-02968	1380 E 48TH PL	90011	9	111A211   143	5107024005	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.20	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	02/21/2015 12:00:00 AM	ADDRESS	33.99918	-118.25021	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 4KW DC.(16) HUYINDAY MODULES(16) ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55355	14041-20000-27352	14870 W LA VALLE ST	91342	7	225B149   330	2505001044	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.3121	-118.45657	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNECTED WITH MSP.(16) HYUNDAI 250 MODULES(16) ENPHASE M215 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55356	18041-10000-07019	9915 W ANTHONY PL	90210	5	150B153   998	4356004012	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.10322	-118.43263	Full pc for power only for a New two story single family dwelling. Scope includes a new 600A 120/240 single phase  3 wire service/distribution board, new panels, and new circuits. B#14010-30000-04009NOTE: Permit is paid under building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55357	14041-10002-28084	899 S FRANCISCO ST	90017	14	129A207   155	5144023054	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	34.04731	-118.2643	MODIFYING SINGLE LINE DIAGRAM TO SHOW THE REFEEDING OF RISERS R2 AND R3 WHICH ARE TO SUPPLY THE TEMPORARY POWER SKIDS; IDENTIFYINY MV FUSES ON MV-DB-R2((((((5,000 amp temp power for new hotel buildings with temp distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55358	15041-20000-32025	15222 W VENTURA BLVD	91403	4	168B145  1166	2276007059	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.15331	-118.46466	Plan check for energy only. TI to existing retail space (adding partition walls to create new offices). New lighting (incl. emergency) and receptacles. 4,090sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55359	16041-10001-23998	850 S CRENSHAW BLVD	90005	4	132B189   661	5092002031	R3-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			10/13/2017 12:00:00 AM			PC Info Complete	10/13/2017 12:00:00 AM	ADDRESS	34.05763	-118.32112	Changes made to previously approved set. Described as standup switchgear section changed from attached to detached. Per MZ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55360	18041-10000-41651	20928 W OSBORNE ST	91304	3	195B109    59	2779002089	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Issued	10/31/2018 12:00:00 AM	ADDRESS	34.23292	-118.58933	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55361	18041-20000-40364	1990 S BUNDY DR Ste 430	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.03419	-118.45559	Tenant improvement to (E) commercial high-rise office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55362	13041-10001-14444	6901 N TUJUNGA AVE	91605	2	183B173   184	2320002013	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			06/04/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.19626	-118.37921	8/18/14  CHANGES TO APPROVED SET. DELTA 3 CHANGES ONLY. ALL CHANGES ARE CLOUDED. CHANGES TO T24. REMOVING AND ADDITION OF FIXTURES.Main App Description:    NEW BUILDING WITH NEW 277/480 VOLT 3-PHASE 4-WIRE, 3000 AMP SERVICE. 66,469 SQUARE FEET OF INDOOR LIGHTING AND 3,036 SQ FT OF OUTDOOR LIGHTING. OFFICE, INDUSTRIAL, AND STORAGE USE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55363	10041-10000-23376	4848 W JEFFERSON BLVD	90016	10	120B181   805	5046011004	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/01/2010 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	04/21/2011 12:00:00 AM	ADDRESS	34.02539	-118.35009	New service for remodeled building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55364	17041-10000-13432	5353 W PICO BLVD	90019	10	129B177   948	5085033017	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.04858	-118.35493	NEW FA SYSTEM FOR SCHOOL. PC FOR FIRE ALARM ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55365	14041-10000-34475	12930 W HAMLIN ST	91606	2	180B161   917	2326016015	R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.18833	-118.41494	Title 24 plan check only.  Total area = 4,565 sq. ft.Remove HID light fixtures and replace with LED lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55366	14041-20000-35731	4828 N SUNNYSLOPE AVE Bld. 1A	91423	2	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	12/16/2021 12:00:00 AM	ADDRESS	34.1586	-118.42623	New 3 story apaartment with 20 units.  New 800A service, panels, and branch circuits. Plan check for power only.Note: Variance to separate fire alarm plans submitted on 12/29/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55367	15041-20000-19380	7320 N WOODLAKE AVE #200	91307	12	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Expired	07/14/2017 12:00:00 AM	ADDRESS	34.20263	-118.63189	PLANCHECK FOR T24 ENERGY ONLY. RELOCATION OF LIGHTING FIXTURES FOR BVC PHYSICAL THERAPY. 1367 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55368	18041-10000-09307	3632 S KEYSTONE AVE	90034	5	120B161   999	4314009030	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			03/14/2018 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	12/31/2020 12:00:00 AM	ADDRESS	34.02304	-118.40879	Full PC for a New 4-story 10 unit apartment. Scope includes one 600A 120/240 1 phase 3 wire service/distribution boards and one 300A 120/240 3 phase 4 wire service/distribution board. Also adding new panelboards, new circuits and new lighting. There are three typical unit panelboards. Total affected area is 13,664 Sq. Ft. B#17010-30000-05113	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55369	16041-10000-13513	1527 E 32ND ST	90011	9	117A213   373	5117001008	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	ADDRESS	34.01264	-118.24751	TI to an (E) storage build. Install new lights and control receptacles. PC for Energy only, total area: 4,821 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55370	15041-10001-05482	3770 N CAHUENGA BLVD	91604	4	162B177   423	2425001069	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	34.13641	-118.3623	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE NEW LIGHTING LAYOUT AND NEW LOCATION OF SERVICE. ALL CHANGES CLOUDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55371	17041-20001-22680	3660 W WILSHIRE BLVD	90010	10	132B193    63	5093019020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.06155	-118.30505	7/31/2018changes to an approved set of plans.  changes to decrease system size to 180KW AC.  Line side tap.this is plan check only.  (((Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,052) modules, and (1) load center.Note: Permit Fees $0 due to SB 1222Note: Building application has been generated under 17014-30000-03171)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55372	15041-10000-39568	12411 W FIELDING CIR	90094	11	105B161  1220	4211034062	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	33.97968	-118.40871	"PROPOSED 5' X  20' S/F  LEDs ILLUM BLADE  SIGN ""B""  ("" VILLAS AT PLAYA VISTA  APARTMENT HOMES)PLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55373	15041-10000-32157	9031 N LURLINE AVE	91311	3	198B109   193	2780001058	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.23463	-118.58443	NEW FIRE ALARM PANEL FOR A SPRINKLER MONITORING SYSTEM. PC FOR APPLICANTS REQUEST. FEES FOR DEVICES PAID UNDER APP# 15041-10000-10956.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55374	13041-20000-28718	12455-12457 N SAN FERNANDO ROAD	91342	7	219B149   497	2611001008	(T)(Q)RAS3-1VL	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Apartment			10/15/2013 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.29675	-118.45633	PC FOR POWER AND ENERGY. NEW 61 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55375	14041-10000-22889	1505 S PACIFIC AVE	90731	15	012B197   377	7454032025	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.01	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	33.73036	-118.28812	plancheck for t24 energy. Tenant improvement to existing retail building,13340 sqft, emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55376	17041-10000-11784	6222 W WILSHIRE BLVD #500	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.06309	-118.36418	PC FOR ENERGY. T.I OFFICE. CONNECTED LOAD <400A. AFFECTED AREA 776 SQ FT. B# 17014-10000-00272	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55377	16041-10001-26174	540 E ROSE AVE	90291	11	111B141   333	4240010008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	33.99852	-118.4729	11/18/16. Changes to approved set of plans. All changes are clouded under delta 6. Changes to include to reflect what is on the field for the lighting fixtures, and adding 1 water heater.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55378	14041-20001-13379	2768 W FYLER PL	90065	14	159A219    69	5684019020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	05/27/2014 12:00:00 AM	ADDRESS	34.13152	-118.22676	Expedite per customer request7.5KW PV1 roof-mounted system with (2) Solaredge transformerless inverter model #  SE3800A-US, (30) Renesola modules model # JC250M-24/BB and a Solaredge Power Optimizer model # P300.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55379	15041-20000-17995	3754 E MERCURY AVE	90031	1	142-5A227 226	5305012012	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.0847	-118.19841	Installation of new roof mounted solar PV array.  Total area = 3.75 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55380	10041-10001-06167	5333 W ZOO DR LSS, STILT-HARPY	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	9800.09	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM			PC Approved	05/29/2012 12:00:00 AM	ADDRESS	34.14867	-118.28623	Change the approved plan. Rerouting the conduite to meet the bending requirments from inspector.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55381	17041-20000-02968	21650 W OXNARD ST Ste 1900	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.17901	-118.60107	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55382	15041-10000-08256	8635 N ROBERT AVE	91352	6	192B173    89	2408018001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.22615	-118.3717	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.2KWAC. 17 MODULES AND 1 INVERTER. SUBMITTED PER APPLICANT REQUEST. delete additional comments	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55383	14041-20000-02926	11111 W TUXFORD ST	91352	6	195B173   102	2408033037	M3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.23321	-118.37349	UPGRADE SERVICE TO 600A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55384	19041-10000-21958	21725 W VICTORY BLVD	91303	3	180B105    77	2139004045	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.18791	-118.60217	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INLCUDES INTERIOR T.I. TO (E) RETAIL SPACE INCLUDING-ALTERATIOS TO (E) FITTING ROOMS. NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 610	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55385	14041-20002-21435	19941 W LORNE ST	91306	3	189B113   179	2106026012	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2014 12:00:00 AM			PC Approved	09/17/2014 12:00:00 AM	ADDRESS	34.2173	-118.56811	FEE IS $0.00 BY STATE SENATE BILL NO. 122MODIFICATIONS TO AN APPROVED SET OF PLANS.  REMOVE FIVE TRINA SOLAR TSM-255 MODULES AND CHANGE INVERTER FROM SOLAREDGE TO POWER ONE 6000. PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(1) SOLAR EDGE SE6000 TRANSFORMERLESS INVERTER(33) TRINA SOLAR TSM255 MODULES(33) SOLAR EDGE OPTIMIZER P300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55386	18041-10001-24626	4538 W MELBOURNE AVE	90027	4	150B197  1172	5590022004	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Apartment			05/24/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	34.10348	-118.28897	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 2 INVERTERS (SE3600H-US) WITH 28 MODULES USING P370 OPTIMIZERS. TOTAL SYSTEM SIZE IS 9.38KWdc / 7.60KWac.NOTE: PERMIT FEES ARE PAID UNDER MASTER APPLICATION PCIS#18041-90000-24626	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55387	18041-20000-36380	6255 W SUNSET BLVD ste 800	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	ti to an existing commercial building (high rise) adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55388	19041-20002-25136	6617 N BEN AVE pv1	91606	2	180B165   354	2322009052	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1232.04	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.19086	-118.39444	SUPPLEMENTAL, PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET. CHANGE OF MAIN SERVICE PANEL FROM 225A TO 200A AND DERATING MAIN CIRCUIT BREAKER FROM 200A TO 175A, AND ADDITION OF A SERVICE LOAD CALC PAGE. CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55389	19041-20002-06857	8500 S PERSHING DR PV-1	90293	11	096B153  1023	4118004015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Issued	07/22/2019 12:00:00 AM	ADDRESS	33.9561	-118.442	Revisions to approved set.  Change of module type and quantity - (105) modules total.  Change of supply-side interconnection detail. Work description revised to: PV2.  Install 38.33 kW DC / 35.02 kW AC roof mounted grid tied PV system.  (105) modules with (2) 20 kW rated inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55390	11041-20000-26669	8900 N DE SOTO AVE Blg 102	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.23162	-118.58832	T24 lighting plan check for remodeled room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55391	18041-20000-21178	15910 W VENTURA BLVD SUITE 1405	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Issued	06/07/2018 12:00:00 AM	ADDRESS	34.15561	-118.47969	PLAN CHECK AT THE COUNTER FOR TITLE 24 ONLY FOR TI FOR EXISTING OFFICE - TOTAL AFFECTED AREA = 1172 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55392	17041-10000-41591	835 W 255TH ST	90710	15	036B197   773	7413024046	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	33.79289	-118.29024	PC for T24 only for new outdoor parking lighting. Total area is 30362sqft. B#17030-40000-04177	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55393	19041-10000-16205	2329 S CLOY AVE	90291	11	106-5A147 131	4228007013	R1-1	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	33.98678	-118.45968	[e-Plan]  Install New 13.5 kWh Tesla Energy Storage System & New 200 AMP Load Center. There's an (E) 5.2 kW AC PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55394	16041-10000-44929	3551 W CASITAS AVE LOT 1	90039	13	156B209   288	5436004026	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.12102	-118.25697	Plan check for Power 11 buildings SFD live work  2 story building on 1 parcel  feed by 1 Service 1000A. 11 Buildings are on 1 plan.  Note: Master Application Lot 1 type D	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55395	16041-10000-00087	10400 S MANHATTAN PL	90047	8	090A193    84	6058023024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Expired	02/02/2018 12:00:00 AM	ADDRESS	33.94163	-118.31003	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.64KWdc/3.6KWac.(16)MODULES-SILEVO #TRIEX U290 BLACK(1)INVERTER-ABB #PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55396	19041-20000-30141	4800 S AVALON BLVD	90011	9	111A207    96	5108009036	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2292.00	Electrical	Electrical	Apartment			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	33.99952	-118.26503	Plan check for new fire alarm system for 5 story 33 multi-family building. Total fire alarm devices: 141 and 1FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55397	17041-10000-28559	3644 S OVERLAND AVE	90034	5	120B161  1167	4314010077	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.02231	-118.40953	FA SYSTEM FOR NEW 6 STORY APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55398	18041-10000-19468	5563 W ADAMS BLVD	90016	10	123B177   969	5048001057	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.03264	-118.36417	CONSTRUCTION OF A NEW TWO STORY COMMERCIAL BUILDING.FULL PLAN CHECK FOR POWER AND ENERGY.BLDG PERMIT # 18010-10000-01372	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55399	18041-10000-39341	6130 S AVALON BLVD	90003	9	105B205   683	6007009025	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	33.98365	-118.26499	NEW FIRE ALARM SYSTEM TO A COMMERCIAL BUILDING. (1) FA PANEL, (170) FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55400	15041-20000-22869	10459 N DE SOTO AVE	91311	12	207B109   603	2706016019	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.26062	-118.58889	Plan check for PV roof mounted system. System size: 3.8kW with 14 modules and 1 inverter(3.8kW). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55401	18041-30000-31722	3301 S CORINTH AVE	90066	11	120B157   998	4250023026	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.02109	-118.42886	Install New Rooftop Solar System (PV1) on a SFD. (6) AP system YC500A, (12) SWA300 Mono modules. System rated is 3kW AC/ 3.06 kW DC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55402	13041-10000-12496	14932 W BLEEKER ST	91342	7	216B149    59	2611019021	RS-1	North Valley	Sylmar	Sylmar	YES	1066.05	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Finaled	07/15/2013 12:00:00 AM	ADDRESS	34.29219	-118.45616	PV1 9.3KW 38PANELS (TSM-245PA05.08 ). 2 INV (inverters SE3800A-US and  optimizers OP250LV). SOLAREDGE/OPTIMIZERS ROOFMount. NONSTandarD plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55403	15041-10001-03037	812 S GRAND AVE	90014	14	127-5A209  24	5144019025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	PIN	34.04527178	-118.25793792	03/08/2016Changes to an approved set of plans, note changes on delta 5. Changes include the relocation of the electrical room. voltage drop is minimal and AIC at panel H is 35k, fully rated.  ((PC FOR POWER AND ENERGY. NEW 4 STORY PARKING STRUCTURE WITH SHELL TENANT SPACE AT GROUND LEVEL, DRUG STORE. TOTAL AREA  65569 SQ FT. NON HIGH RISE BUILDING.PLAN CHECKER TO VERIFY THE ISSUE WITH 14041-20000-098765.B# 15010-10000-00375.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55404	18041-10000-36119	333 S GRAND AVE #4100	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLAN CHECK FOR TITLE 24 ONLY FOR - Tenant improvement for (e) office space. Scope include new interior non bearing partitions, millworks, finishes, ceiling, flooring. - TOTAL AFFECTED AREA = 3808 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55405	14041-10000-17817	2200 S UNION AVE	90007	1	124-5A201 216	5124006001	C2-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM			PC Info Complete	08/07/2014 12:00:00 AM	ADDRESS	34.03549	-118.28294	PC FOR POWER AND ENERGY. 4651 S.F. ADDITION TO AN EXISTING 2475 S.F. BLDG and remodel of the (E) 2475 sf bldg.  THE USE OF THE BUILDING WILL BE ADULT DAY HEALTH CARE.BUILDING REFERENCE #: 14014-10K-00364	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55406	12041-10000-16900	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Cut over of existing service to new service located in new TBIT Building and all associated work.  New Building to be completed under separate permit.  (Plan checker to verify fees before issuing permit)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55407	19041-20001-06630	4920 N VAN NUYS BLVD pv1	91403	4	169-5A151  47	2248007139	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Approved	04/29/2019 12:00:00 AM	ADDRESS	34.15995	-118.4485	expeditepv3install roof mounted pv system sized 90KW AC interconnected with msp.(278) adani solar modules 360W(3) solaredge 30KW inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55408	16041-20001-37749	5601-5667 W SANTA MONICA BLVD	90038	13	144B193   593	5536012014	(T)(Q)RAS4-2D	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			08/15/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.0909	-118.31159	Supplemental for change of design for temporary power for construction.Downsizing from 1600A to 1200A 480Y/277V service. Installing temporary cranes, elevators, transformers and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55409	11041-20000-22920	555 W 5TH ST 19th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I.  Remodel of the light fixtures on the 19th floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55410	19041-20000-16804	20439 W MANDELL ST	91306	3	192B109   577	2781026014	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.22182	-118.57915	PV1.  Install 4.68 kW AC roof mounted grid tied PV system.  (13) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55411	14041-10000-15329	18571 W CASPIAN CT	91344	12	219B125   160	2601075045	RE20-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.29756	-118.53784	PV1 11KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(40) inverters: {MICROINVERTER: ENPHASE ENERGY M250-60-2LL-S22]}]. [(40)modules: {solarworld SunModule SW-275 mono}]     the solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55412	18041-10000-23122	1000 N SWARTHMORE AVE #5-103	90272	11	129B125   562	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.04747	-118.52552	"***SEE APPLICATION NOTES****PC FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR  ""Amazon"" book store IN PALASADES VILLAGE MALL. TOTAL AFFECTED AREA 4388 SQ. FT. SCOPE INCLDES NEW PANEL, CIRCUITS, EQUIPMENT AND LIGHTS. B#18016-10000-19786"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55413	13041-10000-26911	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	TITLE 24 ENERGY PLAN CHECK ONLY. NO CHANGE IN OCCUPANCY. TOPANGA MALL. UNIT # TO BE PROVIDED.  593 SQFT . EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55414	16041-20000-26315	13755 W ROSCOE BLVD	91402	6	192B153   739	2637029003	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	04/22/2024 12:00:00 AM	ADDRESS	34.22182	-118.43315	New 2-story commercial building core and shell with subterranean parking garage.  4000A 120/208V service.  Plan check for power and energy.COMPLY WITH DEPARTMENT ORDER effective date 02/01/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATEBuilding permit under 16010-30000-03198	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55415	13041-10000-00769	942 N YALE ST	90012	1	135A215    46	5414004006	C2-2D	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			01/11/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.0661	-118.23918	2 STORY OFFICE SPACE/SUNDAY SCHOOL.  REMODEL OF BUILDING, EXISTING SERVICE AND PANELS BUT NEW LOADING AT GREATER THAN 400 AMPS. ALL WORK WILL BE INTERIOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55416	17041-20000-43200	410 S LINCOLN BLVD	90291	11	111B145   694	4243018002	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Issued	12/21/2017 12:00:00 AM	ADDRESS	34.00072	-118.46616	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55417	14041-10000-17555	1281 S WESTWOOD BLVD 2nd Floor	90024	5	132B153   638	4324004013	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.05712	-118.44308	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55418	16041-10000-26376	12100 W WILSHIRE BLVD STE 340	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	PC FOR T.I. TITLE 24 (ENERGY ONLY). INSTALLATION OF LIGHT AND RECEPTECALES. TOTAL AREA 1486 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55419	10041-10003-20702	928 S WESTERN AVE # A-3	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM			PC Approved	02/07/2011 12:00:00 AM	ADDRESS	34.05485	-118.30886	Change the approved plan. Change the quantity of lights. EPC is for T24. (((((((((((((T-24 ( and emergency lighting) for remodeled space A-3.))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55420	07041-10001-26024	1401 S KELTON AVE 10968-Wilkins	90024	5	132B153   980	4324038004	[Q]R4-1L	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Apartment			09/14/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.054	-118.44347	(((((((((((((((Resubmit Expired Plans))))))))))         New 5-story 24-unit condominium building with 2 levels of subterranean garage.  New 120/240V 3ph 4W 2000A service. Buildinglocated in a methane zone.  EPC: Power and Energy(T-24).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55421	14041-20000-30002	5056 E YORK BLVD	90042	1	156A225   340	5477001012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.12099	-118.20503	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING TRACK LIGHTING TO EXISTING POWER EQUIPMENT.  1077 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55422	18041-10000-17504	3724 S VINTON AVE	90034	5	120B165  1178	4314005015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.02277	-118.4039	CORE & SHELL FOR THE INSTALLATION OF A 600 AMP SERVICE AND 5 PANELS FOR 5 SINGLE FAMILY HOMES. UTILITY EASMENTS WERE FILED FOR THE SUBDIVISION TO BE VERIFIED DURING PLAN CHECK.BUILDING PERMIT # 16010-30000-01380	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55423	14041-10000-23824	213 S 1ST ANITA DR	90049	11	132B141   986	4405030032	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.05406	-118.48303	PV1 Microinverter Standard Plan, 6.45kw roof-mounted system including (19) Solarworld sw270 modules and Enphase M215 microinverters; connecting thrould a load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55424	13041-10000-23800	11205 S BROADWAY	90061	8	087A203   167	6074024002	R3-1	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Apartment			08/30/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	33.93272	-118.27879	"Senate Bill No. 1222. Plan check and permit not to exceed $1000. Permit fee $0. for PV 2 ( APARTMENT).  PLAN CHECK FOR ROOF MOUNTED 36.6KW DC PHOTOVOLTAIC SYSTEM. THE PHOTOVOLTAIC SYSTEM IS UNDER LADWP ""FEED IN TARIFF"" PROGRAM. INTERCONNECTION DIRECTLY TO LADWP GRID AND IS INDEPENDENT FROM BUILDING ELECTRICAL SERVICE."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55425	10041-10000-13799	1999 S AVENUE OF THE STARS 20TH FL	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	09/03/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.05886	-118.41642	REMODELING OF OFFICE SPACESPLAN CHK IS FO RTITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55426	18041-20001-00660	110 W 11TH ST Ste 400	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.0392	-118.25858	04-06-2018 Changes to an approved set of plan. Changes include additonal lighting in corridor. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55427	17041-20003-16993	9408-9410 N OWENSMOUTH AVE	91311	12	198B105    66	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/13/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	PIN	34.2410613	-118.60115579	"12/13/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes include the removal of ""HDS2"" and the relocation of a transformer and a fused disconnect switch.11/30/17changes to an appropved set of plans.  changes noted delta 1.  changes include alteration to existing lighting system, revised energy calculations.  plan check for energy indoor only.  (((PC for power and energy for TI for electronic manufacturing facility in second floor of building. PC includes check for new 3000 A 277/480 service, new electronic manufacturing equipment, spray booth, outdoor compressor and power supply units for equipment. Total affected area is 15369 sqft.Bulding # 17016 20000 05741)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55428	18041-10001-00231	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			Not Ready to Issue	10/09/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR CHANGES TO APPROVED SET FOR RESTROOM RECONFIG BASED ON SPATIAL CHANGES AND CORRIDOR STAIREWELL AREA. SCOPE INCLUDES NEW LIGHTS AND RECETACLES. PERMIT UNDER MASTER  THIS IS IS PC CHECK ONLY! B#17014-10001-05320.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55429	12041-20003-14826	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM			PC Approved	10/18/2012 12:00:00 AM	ADDRESS	33.97704	-118.40702	Changes to 12041-20000-14826. Removal of all car chargers, associated panels, and transformer.Plan check per customer's request.{ 12041-20000-14826: Install new 3000 ampere service equipment, feeders to new buildings, and site lighting for industrial park.  Plan check to ask for all missing  93.0207 details.  Methane zone. }	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55430	11041-20000-02943	1100 S GLENDON AVE 12TH FL	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING TENANT IMPROVEMENT ON 12TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55431	12041-10000-00873	500 S VIRGIL AVE #308	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM			PC Approved	01/13/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	T.I. to an existing Office building with  no surgery in suite #308.  Change to lighting and adding receptacles.  4-story building.  Plan Check ONLY.  Permit was issued under 12041-10000-07393	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55432	13041-20000-01144	20465 W SHERMAN WAY	91306	3	183B109    59	2114017015	P-1VL, [Q]C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM			PC Approved	01/16/2013 12:00:00 AM	ADDRESS	34.20128	-118.57936	T-24 and emergency lighting plan check for storage space identified as storage #2 and #3 on the plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55433	15041-20000-44028	14101 W GOLETA ST	91331	6	198B153   730	2642006008	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.23806	-118.44023	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (18) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55434	15041-20003-36375	10420 N SEPULVEDA BLVD BLDG 2	91345	7	204B145    23	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.25976	-118.46706	"8/10/17changes to an approved set of plans.  changes noted ""EV"" only.this is plan check only.(((7/11/17changes to an approved set of plans.  changes noted delta EV only.  adding panel 2EVB and circuits.Revisions to approved set of plans.  Value engineering changes and gear orientation revision.  Approval for clouded changes delta-J only.)))  (((NEW TWO FLOOR MULTI USE BUILDING. CORE AND SHELL ONLY.  PLAN CHECK FOR POWER AND ENERGY.BUILDING APLLICATION# 15010-10000-03863)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55435	16041-10000-35454	25424 S BELLE PORTE AVE	90710	15	036B193   604	7410027067	[Q]R3-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	33.79299	-118.30095	PV1 roof mounted solar system installation to a singe family home. Installing a central inverter rated at 3.8KWAC and 16 solar modules with its respective optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55436	15041-10000-23445	333 S GRAND AVE 19TH FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Closed	08/10/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLAN CHECK FOR ENERGY ONLY FOR TI TO EXISTING OFFICE SPACE. SCOPE OF WORK IS ON THE 19TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55437	19041-20000-50448	2242 N CHESWIC LANE	90027	4	150B197    19	5588009019	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	02/03/2021 12:00:00 AM	ADDRESS	34.11151	-118.29663	PV1. INSTALL 7.68 KW DC PV SYSTEM WITH (24) MODULES/OPTIMIZERS AND (1) INVERTER(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55438	12041-10000-26512	17329 W SAN JOSE ST	91344	12	207B133   751	2733026***	(Q)RD6-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM			Reviewed by Supervisor	12/07/2012 12:00:00 AM	ADDRESS	34.26133	-118.5121	INSTALL ON ROOF OF SFD A 5.04KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55439	14041-10001-16478	5177 W PICKFORD ST	90019	10	126B181   290	5067001015	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	08/21/2014 12:00:00 AM	ADDRESS	34.04402	-118.35229	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{[PV1, INSTALL 3.57 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 4 UNIT PROPERTY, INTERCONNECT WITH MAIN SERVICE PANEL. ON TRANSFORMERLESS INVETER, WITH OPTIMIZERS.(14) MODULES: TRINA SOLAR # TSM-255PA05.18(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3800A-US-ZB-U}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55440	16041-10000-16053	17383 W SUNSET BLVD	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, PC FOR ENERGY ONLY, NEW OUTDOOR LIGHTING TO AN EXISTING SPACE. TOTAL SQ. FT. 2352	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55441	12041-10001-16348	3434 S HOPE ST	90007	9	118-5A203  74	5122021010	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM			PC Approved	08/30/2012 12:00:00 AM	ADDRESS	34.01983	-118.27801	SUPPL APP. FOR THE CHANGES TO THE ORIGINAL DESIGN FOR INSTALLATION OF A TELECOM FACILITY INSIDE AN EXISTING PARKING STRUCTURE @ USC CAMPUS.  New 600A Service, panels, circuits, and lightintg.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55442	18041-20000-36274	17600 W MCCORMICK ST	91316	5	171B129   167	2257005039	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.16571	-118.51677	PV1.  Install 19.101 KW AC CEC roof mounted grid tied PV system with 74 modules and 74 microinverters connected to 400A panel service.  $0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55443	18041-10000-07377	2175 W COLORADO BLVD	90041	14	162A223   101	5671012029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.13932	-118.21389	PC for T24 only for replacement of indoor lighting to LED fixtures with LED driver for Chase bank. Egress lighting is not part of the scope. Total area Indoor  is 4800sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55444	11041-10000-12068	3240 W WILSHIRE BLVD # 510	90010	10	132B197    42	5094008018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.06162	-118.2924	ADDITION TO EXISTING DENTAL OFFICESPLAN CHK IS FOR TITLE 24 ;PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55445	18041-10000-47521	7055 N BELLAIRE AVE	91605	2	183B161   314	2324018086	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.19904	-118.40961	$0 FEE DUE TO ASSEMBLY BILL 1414PC FOR (N) ROOFTOP PV SYSTEM (5.76 KW AC 240V) FOR (E) SINGLE FAMILY DWELLING. Installing (24) SUNSPARK TECHNOLOGY PV MODULES EACH WITH INDIVIDUAL  MICROINVERTER (ENPHASE IQ-60-2-US) WITH 1A OUTPUT, AND (1) 200 A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55446	17041-10000-00312	6380 W 6TH ST	90048	5	135B173   697	5510025018	R2-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.06549	-118.36773	PV, INSTALL NEW 5.40 KW DC/4.80 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A DWELLING HOUSE.(15) PANELS: SPR-X22-360-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55447	12041-10000-22979	1914 S BUNDY DR	90025	11	123B149   282	4259020013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.03484	-118.45635	TI in an existing sport club. New panels, ckts, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55448	13041-20000-16581	16430 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Expired	07/21/2015 12:00:00 AM	ADDRESS	34.1937	-118.49137	NEW LIGHTING IN TENANT SPACE. PC FOR T24 ENERGY ONLY. NEW CONNECTED LOAD < 400A. PC AND PERMIT UNDER THIS APPLICATION. TOTAL AREA 9321 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55449	19041-20001-01682	732 S LOS ANGELES ST C	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.04251	-118.25112	APPROVAL OF COPY OF ORIGINAL SET. PLAN CHECK ONLYPLAN CHECK FOR TITLE 24 ONLY FOR HAIR SALON. SCOPE INCLUDES TOTAL SQFT OF 1151.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55450	15041-20001-13181	112 E 22ND ST Bldg 9-10	90731		012B201   214	7440034901							Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	33.72783	-118.27968	expedite feesPV2 commercial rooftop solar system. system utilizes 2 buildings. both buildings interconnect to a single service point. The solar system is a Feed in terrif. System directly sells electrical energy to utility company. This system is noted as a single 1.2MW DC system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55451	19041-20000-30976	5457 N LEMONA AVE	91411	4	174B145   718	2250013028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.17014	-118.45982	PV1.  Install 4.095 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (13) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55452	19041-10001-03645	150 N SOTO ST	90033	14	127-5A223  77	5180002025	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			03/29/2019 12:00:00 AM			Reviewed by Supervisor	04/08/2019 12:00:00 AM	ADDRESS	34.04488	-118.20883	Replacement of the Lost Marked up Plans<<<PLAN CHECK FOR POWER ONLY. CONVERTING EXISTING 61 GUESTROOMS TO LIGHT HOUSE-KEEPING. SCOPE OF WORK INCLUDES NEW PANELS AND CIRCUITS EQUIPMENT ON AN EXISTING 800A DISTRIBUTION SYSTEM. NEW CIRCUITS ARE FOR RANGES, WASHERS AND DRYERS UNITS. ONE NEW LIGHT FIXTURE FOR ONE COMMON AREA BATHROOM. TOTAL CONNECTED LOAD OVER 400AMPS.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55453	13041-20000-13962	2638 N WALLINGFORD DR	90210	5	156B153   189	4382007015	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	ADDRESS	34.12122	-118.43439	PV1 MICROINVERTER PLAN CHECK. 51 MODULES. TOTAL SYSTEM SIZE IS 13KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55454	19041-10000-29763	2550 W BEVERLY BLVD	90057	13	136-5A203 130	5155024015	C2-1	Central	Westlake	Echo Park		2086.20	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/15/2020 12:00:00 AM	ADDRESS	34.06898	-118.27614	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55455	13041-20000-18841	14800 W VENTURA BLVD	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.15186	-118.45547	INSTALLATION OF FUEL CELL SYSTEM. UTILITY INTERACTIVE. PC FOR POWER. 200KW RATING EACH FUEL CELL. TOTAL SYSTEM SIZE 1MW. NEW TRANSFORMER, 3 PANELS, 600V EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55456	10041-10000-24980	566 S SAN PEDRO ST 1ST FL	90013	14	127-5A213 437	5147024023	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Finaled	11/02/2011 12:00:00 AM	ADDRESS	34.04245	-118.24485	REMODELING OF EXISTING OFFICE SPACESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55457	13041-10000-36048	1105 S SAN JULIAN ST	90015	14	124-5A211 350	5145024***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.03572	-118.25342	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 468 SQ FT. REPLACING TOTAL OF 3 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55458	15041-10000-20844	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	Installation of (N) fire alarm system to (E) commercial retail building.  122 device system with new fire alarm control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55459	11041-10000-26987	1425 E 6TH ST	90013	14	126A217   118	5164007017	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	12/27/2011 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	PIN	34.03864449	-118.2318869	T.I. to fire damage building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55460	19041-10000-29549	22205 W ERWIN ST	91367	3	177B101    60	2146002***	[Q]R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.18299	-118.61083	[EPLAN]PLAN CHECK FOR ROOF MOUNTED 6KVA(AC)PV2 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE6000H-US) WITH 17 MODULES USING P400 OPTIMIZERS CONNECTED TO EXISTING 600A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55461	18041-20001-47179	10749 N FARRALONE AVE	91311	12	207B101    54	2723006031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	12/24/2018 12:00:00 AM	ADDRESS	34.26547	-118.61065	Expedite per applicant request Plan check for PV roof mounted system, system size: 15.12kW DC, 13.44kW with 42 AC Modules, 100A sub panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55462	17041-10000-31787	555 S FLOWER ST FLR 31	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.05048	-118.25755	OFFICE TI ON 31ST FLOOR. PC FOR T24 ENERGY ONLY.  SCOPE OF WORK INCLUDES THE REPLACEMENT OF LIGHTING TO LED AND CHANGE OF A SPACE TO OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55463	17041-10000-01746	4016 S CENTRAL AVE	90011	9	115-5A209 248	5114033033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.01063	-118.25627	FULL PC FOR POWER AND ENERGY FOR A NEW TWO STORY COMMUNITY CENTER AND OFFICE FOR SCHOOL(BLDG 1 OF 3). SCOPE INCLUDES A NEW 600A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 9240 SQ. FT. B#16010-10000-03364NOTE: ONE SET OF PLANS ARE SUBMITTED FOR THREE STRUCTURES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55464	18041-10000-20558	318-332 W 15TH ST	90015	14	124-5A207 394	5134015026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.03661	-118.26649	T-24, PC FOR ENERGY ONLY. TI FOR RESTROOMS  ON FLOOR LEVELS 1 THROUGH 4. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1060 SQ. FT. B#17016-10000-24652	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55465	19041-20000-23687	13637 W VENTURA BLVD	91423	4	165B157   618	2360006025	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.14812	-118.43078	T24 ENERGY PLAN CHECK ONLY, FOR TI CHANGE OF USE IN EXISTING COMMERCIAL BUILDING FROM OTPOMETRIST TO BEAUTY SALON. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1,673SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55466	13041-20000-03858	1733 N CHEROKEE AVE	90028	13	148-5A185  50	5547009016	[Q]R5-2D	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			02/14/2013 12:00:00 AM			PC Info Complete	02/25/2013 12:00:00 AM	ADDRESS	34.1025	-118.33488	Plan check for service upgrade. Service upgrade and tenant panels plus house panel. No unit loads. Permit is on 13041-20001-03858.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55467	19041-20000-40916	7911 W HILLROSE ST	91040	7	207A195    74	2556031016	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.2634	-118.30527	PV roof mounted system, PV system size: 8.25KW DC, 7.6KW AC with 17 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55468	17041-20000-20700	639 N FAIRFAX AVE	90036	5	141B177   747	5527017005	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.08281	-118.36175	Plan check for fire alarm system. New fire alarm system for 5-story, 63-unit apartment building. 1 FACP. 172 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55469	16041-10004-38993	10250 W SANTA MONICA BLVD 2705	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Issued	02/20/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Revision to ""Eataly"" approved plan due to Fire Department Correction Notice dated 1/30/18. Revision noted under Delta 17 and only applies to Level 5: Add (2) inverters, exit signs and egress lights in restroom hallway, keg room (chiller/fridge room), restroom vestibule, RVT Dining, Top of Spiral stairwell, kitchen BOH, Bar and BOH corner. Exit signs and emergency lights are fed from inverters.*Note: This set of plan is stamped and signed by different engineer but still under the same engineering company as the previouse EoR."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55470	14041-20001-35853	20524 W GERMAIN ST	91311	12	207B109   568	2707012021	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.26155	-118.58078	Expedited per customer request.PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service pannel.(34) Sunpower SPR-327NE Modules(1) Sunnyboy SB3000 Inverter(1) Sunnyboy SB7000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55471	18041-20000-18908	5670 W WILSHIRE BLVD STE 1350	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI to (E) highrise commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55472	11041-10000-03859	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/29/2011 12:00:00 AM		Permit Finaled	05/03/2011 12:00:00 AM	ADDRESS	34.07149	-118.19797	NEW GENERATOR AND UPS FOR FOREVER 21.  REGULAR PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55473	16041-10001-45800	802 S FRIES AVE	90744	15	024B205    34	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM	06/19/2018 12:00:00 AM		Issued	06/19/2018 12:00:00 AM	ADDRESS	33.76172	-118.26356	CHANGES TO APPROVED SET TO REFLECT ON SITE CHANGES UNDER DELTA 3 ONLY. SCOPE INCLUDES TAPPING EXISTING SWITCH BOARD TO FEED NEW SECTION ON SWITCH BOARD  AND DOWNSTREAM TRANSFORMER FOR FUTURE PV SYSTEM. ALL EQUIPMENT IS MEDIUM VOLTAGE 4160V TRANSORMER RATED AT 1250KVA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55474	18041-20001-25128	7923 N MCNULTY AVE	91306	3	189B109   591	2108014007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	ADDRESS	34.21419	-118.58469	expeditepv1install roof mounted pv system sized 11.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55475	15041-20001-09457	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	ADDRESS	34.2312	-118.36756	10-01-2015 Change to approved set of plans. Changes include add light fixture to restroom, layout changes for the parking lot lighting.  Changes apply to delta 1 only. [[[[[[PC FOR SHELL OUT FOR FUTURE STARBUCKS. INSTALLING BUS EXTENSION FOR FUTURE RETAIL. PC FOR POWER and ENERGY. INSTALL RESTROOM LIGHTS.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55476	10041-20000-06822	"17940 W VENTURA BLVD UNIT ""A"""	91316	5	171B129   266	2182001004	C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1395.02	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	ADDRESS	34.16393	-118.52349	INSTALLING LIGHTING IN CANDY STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55477	16041-20000-45347	2466 E 16TH ST 1ST FLR-MEZZANINE	90021	14	118-5A217 294	5168010013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.01949	-118.2277	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 2940 SQ. FT. B#16016-10000-30124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55478	17041-10001-36876	4222 S EDGEHILL DR	90008	10	114B185   659	5024023025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	ADDRESS	34.00768	-118.33033	Supplemental for expedite PV fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55479	16041-10000-04551	1101 W VIA FRANCISCA	90732	15	021B193    97	7445018044	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Expired	03/09/2018 12:00:00 AM	ADDRESS	33.75434	-118.30236	PV1 rooftop solar installation 8.2kW.(41) KU2656ZPA(1) FRONIUS PRIMO 8.2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55480	16041-20000-09548	16901 W NAPA ST	91343	12	195B133   508	2689018032	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.22679	-118.50046	PV2. ROOFMOUNTED SOLAR SYSTEM.  TOTAL SYSTEM SIZE: 364 KW.   TWO BUILDING CONNECTED AS ONE FEED IN TARRIF SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55481	17041-10000-03637	2816 E 11TH ST	90023	14	120A221   150	5169007004	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.02224	-118.21775	PC for energy only outdoor title 24. Removing HID fixtures and replacing them with new  LED ones. Area: 7,900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55482	18041-10000-33955	1501 W CARSON ST	90501	15	051B193   876	7349032033	C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	33.83167	-118.30406	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55483	14041-20000-33181	17075 W CELTIC ST	91344	12	210B133   772	2696014024	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.26937	-118.50488	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING SINGLE TRANSFORMERLESS INVERTER. NON STANDARD PLAN. SYSTEM USES POWER OPTIMIZERSNote: Solar PV installation shall comply with FPB requirement No 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55484	19041-10000-05135	5170 W ADAMS BLVD	90016	10	123B177  1003	5049017008	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Closed	08/03/2021 12:00:00 AM	ADDRESS	34.03226	-118.35495	Full plan check for a new 3-story,  42- guest room  Hotel with retail and restaurant on Ground floor over 1 level subterranean parking garage. Scope includes (1) 2000-Amp 120/208v 3-phase services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55485	16041-10000-18694	12475 BLUFF CREEK DR	90094	11	102B161  1149	4211010059	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	05/17/2017 12:00:00 AM		Issued	05/17/2017 12:00:00 AM	PIN	33.97754762	-118.40825973	PC FOR POWER, SCOPE OF WORK INCLUDES 4 NEW WATER PUMP, 2 UNDER CP-1100, 1 UNDER CP3100, AND 1 UNDER CP 2100, TO A PREVIOUSLY APPROVED SYSTEM. PC PER APPLICANTS REQUEST. CONNECTED AMPS<400AMPSNOTE: LAST PERMIT IS UNDER 05041-10005-03477.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55486	12041-20000-10778	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM			PC Approved	05/10/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I. to existing space for Sub-Zero Icecream (Suite #9210) inside Mall.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55487	16041-10002-40751	1120 W WASHINGTON BLVD	90007	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.03867	-118.28211	03/20/2018PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE SERIES RATING ONLY PANELS HA AND PA, AS WELL AS GROUNDING DETAIL ON SINGLE LINE DIAGRAM - CHANGES HAVE BEEN MADE UNDER DELTA 5 ONLY 11/17/2017CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 3 ONLY. CHANGES INCLUDE THE RELOCATION OF THE PULL SECTION, DOWNSIZING TO 800A SERVICE,  AND MODIFICATION OF EXTERIOR LIGHTING. B# 16010-10000-03993.***PC FOR POWER AND ENERGY FOR  NEW 9 STORY PARKING STRUCTURE. PC FOR NEW 1000 A SERVICE. TOTAL AREA IS 170703 SQFT.*NEW KPARKING STRUCTURE (NINE TIERS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55488	12041-10000-22938	2511 N DALY ST	90031	1	139-5A221 205	5204003020	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			09/26/2012 12:00:00 AM			PC Info Complete	09/26/2012 12:00:00 AM	ADDRESS	34.07571	-118.21587	Title 24 only inside Wells Fargo which is located inside Smart and Final (Existing Wells Fargo) replacing lights and adding 222 square feet to an existing Wells Fargo.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55489	17041-20000-30983	16251 W VINTAGE ST	91343	12	204B137   976	2678008010	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Issued	08/29/2017 12:00:00 AM	ADDRESS	34.25199	-118.48673	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55490	17041-30000-40286	6221 W 96TH ST	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	33.94902	-118.39331	Plan check for Title 24 in Parking Lot C LAWA. Change out the outdoor light heads and relocate 7 light poles. Total area: 855,000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55491	15041-20000-10855	4306 N GRIMES PL	91316	5	165B125   214	2184033018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.14881	-118.52635	Installation of new solar PV array.  Total system size = 10.5 kWac.  Microinverter system with 3 branch circuits.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55492	17041-10000-39026	1253 N BISHOPS ROAD	90012	1	136-5A215  10	5414019007	[Q]R3-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.06976	-118.23428	PC for new FA system for two story school auditorium and small classroom. Installing one FACP, two annunciators, 111 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55493	12041-10000-03475	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	33.89279	-118.28725	Fire alarm for an existing retail store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55494	13041-10000-10059	601 S FIGUEROA ST	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Issued	05/02/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR TITLE 24 SIGN LIGHTING. 4 SIGNS AND 4 CIRCUITS. REFERENCED BUILDING APPLICATION NUMBER IS 13048-10000-00539. REMINDER: TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55495	17041-10000-07292	118 W 95TH ST	90003	8	093A203    72	6053008008	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	33.95005	-118.27475	PC FOR  ROOF TO MOUINT PV SYSTEM USING AC MODULE TYPES. PC FOR 10 MODULES. 3.2KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55496	14041-10000-20605	5861 N SYLMAR AVE	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.17736	-118.44672	PV1 5KWdc. 240V. microinverter. STD. 2story. Roofmount. [(20) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(20)modules: {Trina {TSM-250PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55497	18041-10000-41669	16040 W SHERMAN WAY	91406	6	183B141   128	2224004017	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.20094	-118.48305	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55498	16041-20001-20407	13930 S FIGUEROA ST	90061	15	075B201    24	6132044028	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	33.90432	-118.28254	Expedite per applicat request(((((Plan check for PV roof mounted system. System size: 40kW with 160 modules and 2 inverters(20.0kW) on commercial building ._))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55499	12041-10001-00418	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	33.74512	-118.26099	"ADDED 2HP SUMP PUMP TO MCCB and REPLACED 6HP SUMP PUMP TO MCCAPLANS ARE ""ASBUILT"" SET.(((((((((Install two new 600 ampere MCC in non classified areas, and new motors and associated circuits in hazardous classified areas, Class 1 Div 2."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55500	11041-20000-19780	936 S WESTWOOD BLVD #GR936&290	90024	5	135B153   567	4363019902	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.06291	-118.44513	Plan check T24 Energy/Emergency lighting for UCLA - Care Connect (Suite #GR936 & #290)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55501	15041-10001-01978	403 W ADAMS BLVD A-B	90007	9	121-5A205 317	5126017018	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.02746	-118.27394	04/05/16Changes to an approved set of plans. All change are made under delta 7. Changes to reflect what is on the field per inspector. Note: Permit paid under PCIS#15041-10000-01978 (((CHANGE OF USE FROM OUT MEDICAL OFFICE TO PATIENT CLINIC.    INT TI OF EXISTING BASEMENT IN OUTPATIENT CLINIC,  OSHPD3 AMBULATORY SURGERY CENTER PROJECT OF APPROX 11,000sqft, 2-ORTHOPEDIC OPERATING ROOMS, 5-RECOVERY ROOMS, 1-TREATMENT ROOM, STAFF SUPPORT AREAS, AND FAMILY WAITING ROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55502	17041-10000-03895	9216 N ETON AVE	91311	12	198B105   110	2746010009	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.23851	-118.59429	Plan check for Title 24 only in existing space, remove indoor and outdoor HID fixtures and replace with new LED lighting fixtures. Total area: 35,500 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55503	16041-20000-42436	15855 W COMMUNITY ST	91343	12	192B141   369	2673015044	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.22302	-118.47833	Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter, (42) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55504	19041-20000-14509	2120 N SAN YSIDRO DR	90210	5	150B157    88	4384028007	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.10969	-118.42396	PLAN CHECK FOR ADDITION TO EXISTING SFD PV SYSTEM. ADDING (16) LG PV PANELS WITH IQ7 ENPHASE MICROINVERTERS RAISING THE TOTAL SYSTEM SIZE TO 11.92KW DC/8.64KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55505	16041-10000-23239	255 W 42ND PL	90037	9	114A203   188	5111017015	R2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Expired	08/08/2018 12:00:00 AM	ADDRESS	34.00664	-118.27747	pv1, install new 6625 WDC roof-mounted solar array on a single family house.(25)modules: candian solar CS6P-265p(2) inverters: ningbo ginlong technologies: solis-3k-2g-us	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55506	17041-20000-43236	7834 N SEPULVEDA BLVD	91405	6	189B145   489	2209032003	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.21305	-118.46599	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55507	11041-10000-15690	250 S ROSSMORE AVE	90004	4	135B185    14	5515013001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM			Permit Closed	12/19/2011 12:00:00 AM	ADDRESS	34.06991	-118.32716	T.I.  Existing school gymnasium  / multipurpose room.  Retrofit of the lighting.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55508	17041-20000-20159	6417 N FIGUEROA ST	90042	14	154-5A231 104	5493004008	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Apartment			06/16/2017 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	34.11841	-118.18387	Plan check for power and energy. New 2-story  21-unit apartment building over open garage. 1,000A service.T24 area - 17,729sqft.Note: Building application has been generated under 17010-10000-01480	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55509	19041-30000-04238	6718 N SYLMAR AVE	91405	2	180B149   171	2237003057	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Apartment			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	09/18/2020 12:00:00 AM	ADDRESS	34.19273	-118.44638	Plan check for a fire alarm system for a 2-story, 11-unit apartment building. Fire alarm system consists of (1) FACP and (46) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55510	19041-20000-29435	7310 N ETON AVE #1 - #9	91303	3	186B105   821	2112024012	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Apartment			07/30/2019 12:00:00 AM	06/02/2020 12:00:00 AM		Permit Finaled	05/24/2022 12:00:00 AM	ADDRESS	34.20323	-118.59534	Plan check for power and energy for new 4 story 9 unit multi-family building 800A Service 120/240 3 Phase 4W. Total area: 4600 sq ft. B#15010-20000-02175	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55511	17041-10000-16482	900 W WILSHIRE BLVD	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM			PC Info Complete	05/17/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR RETAIL TI, NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55512	17041-20000-16184	1515 W 240TH ST	90710	15	042B193   718	7439008032	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Info Complete	06/06/2017 12:00:00 AM	ADDRESS	33.8074	-118.30413	replace existing lighting in manufacturing warehouse to LED.  alteration, reduction in lighting load by 50/35 percent.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55513	13041-20000-14821	15301 W VENTURA BLVD SUITE 220	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	34.15411	-118.46654	RENOVATION OF OFFICE SPACE. PC FOR ENERGY ONLY. NEW FIXTURES AND PARTITION CHANGES. EMERGENCY LIGHTING AS WELL. TOTAL AREA 8350 SQ FT. permit already issued under application # 13041-90000-12417	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55514	17041-20000-34732	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	Plan check for solar pv system, roof-mounted on SFD and detached garage.8.88kW ungrounded system.(37) EnPhase M250 microinverters.(37) 290W pv modules.Plan check only.  Permit for this project previously issued under 17041-20000-20266.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55515	12041-10000-06307	1520 W PALOS VERDES DR NORTH BLDG Q	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77935	-118.30423	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building Q. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55516	15041-20000-23432	380 WORLD WAY T19	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	33.94373	-118.40888	TItle-24 plan check only.  Total area = 400 sq. ft.  Remodel of existing duty-free store in LAX.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55517	11041-10000-22739	19755 W VANOWEN ST	91306	3	183B117  1051		(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	08/03/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	FIRE ALARM SYSTEM FOR A NEW COMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55518	19041-10000-15389	14422 W OXNARD ST	91401	4	177A151   121	2245002024	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Issued	04/26/2019 12:00:00 AM	ADDRESS	34.17921	-118.44735	Remove HID fixtures and replace with new LED fixtures (Indoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55519	15041-20002-36741	2500 N SILVER LAKE TER	90039	4	148-5A207  26	5439019017	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2015 12:00:00 AM			PC Approved	11/30/2015 12:00:00 AM	ADDRESS	34.10319	-118.26202	Changes to approved set.  Removal of subpanel and changes to routing details.  (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. PV SYSTEM CONNECTED TO A 400A MAIN PANEL.  TOTAL SYSTEM SIZE IS 3KWac. (12)ACM-SUNPOWER X20-250-BLK-B-AC(1) 60A SUBPANEL)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55520	19041-10000-42772	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	04/22/2020 12:00:00 AM		Permit Finaled	09/09/2022 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR POWER ONLY, SCOPE OF WORK IS ADDING A 225KVA TRANSFORMER AND A 800A DISTRIBUTION BOARD TO AN EXISTING ELECTRICAL SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55521	16041-10000-04266	10990 W WILSHIRE BLVD 5th fl.-	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.0577	-118.44711	TI on 5TH, all electrical equipment are existing. PC for T-24 only. Total area 1040sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55522	15041-10000-43895	12751 W MILLENNIUM	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	TI TO AN EXISTING COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANEL.  PC FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQYARE FOOTAGE 1260.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55523	10041-10000-14711	1446 S BUTLER AVE Bldg 8	90025	11	129B149   200	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Corrections Issued	09/24/2010 12:00:00 AM	ADDRESS	34.0473	-118.45329	NEW SERVICE , PANELBOARDS AND CIRCUITS FOR 19 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55524	19041-20000-12674	2225 W AVENUE 31	90065	1	150B213   675	5456007011	R2-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.04	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.10534	-118.23482	addition of (1) tesla ESS rated 5KW to an existing pv system. plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55525	15041-10000-06514	1050 N VINE ST	90038	13	144B189   743	5534022032	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.08996	-118.32643	PLAN CHECK FOR ENERGY ONLY FOR TI TO EXISTING RESTAURANT SPACE. NOT A FIRST TIME TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55526	10041-20000-03605	9215 N RESEDA BLVD	91324	12	198B125   240	2763009037	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	04/19/2010 12:00:00 AM	ADDRESS	34.23786	-118.53629	PV SYSTEM 1.4 KW FOR RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55527	08041-10002-19283	3000 W 6TH ST 1st-2nd Floor	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown	YES	2111.20	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	PIN	34.06351748	-118.28745252	Minor changes to previously approved set of plans to show as built condition.  Delta # 6 changes only.  Replace prevously approved pages with modified pages.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55528	12041-10000-23593	8024 S COWAN AVE	90045	11	099B165   429	4109019014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	33.96841	-118.40274	FOR A SFD, ROOF-MOUNTED 2.45KW PHOTOVOLTAIC SYSTEM USING MICROINVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55529	13041-20000-21024	2451 E 15TH ST	90021	14	120A217   193	5168010919	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.02083	-118.22863	New Commercial Shell Building 226,955 sq ft.  Full Plan CHeck.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55530	14041-10000-20737	1000 S GRAND AVE	90015	14	127-5A209 199	5139009012	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			08/12/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.04258	-118.26079	new fire alarm system. Exisiting apartment building with commercial spaces on bottom floor. High rise	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55531	17041-20000-21342	1055 W 7TH ST	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.0507	-118.26334	PV2. ROOFMOUNTED SOLAR SYSTEM.  PARKING CANOPY ON ROOF OF A PARKING STRUCTURE. 309  KW DC.( 952) PS325M PV MODULES(5) PVI 60TL SOLECTRIABuilding permit  # 17014-20000-03025  OPEN SOLAR PARKING CANOPY$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55532	17041-20001-29817	18205 W RAYEN ST	91325	12	195B125   381	2769013001	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM			PC Approved	09/11/2017 12:00:00 AM	ADDRESS	34.23194	-118.52974	[[9/11/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO MEET SITE CONDITIONS. MAIN PANEL CHANGED TO 200AMPS]]]]PC FOR PV SYSTEM RATED 13.1KW AC USING 38 MODULES AC TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55533	16041-20000-31868	12344 N VILLAR WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29498	-118.45482	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55534	18041-20000-32850	20101 W WELLS DR	91364	3	171B113   408	2166009003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.16259	-118.57055	Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWdc/13.99 kWac-CEC and consists of (2) inverters, (48) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55535	19041-20000-18617	5506 W THORNBURN ST	90045	11	102B173   503	4103022009	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Apartment			05/17/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	12/09/2022 12:00:00 AM	ADDRESS	33.97234	-118.37618	new apartment building 800 amp service.  plan check for power and energy.3 story, 12 units, 4 typical unitsbuilding application number 18010-20000-04140	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55536	10041-10000-17481	2000 S AVENUE OF THE STARS 1ST Floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	TI IN AN EXISTING COMMERCIAL AREA ON THE 1ST FLOOR in Suite #30. PLAN CHECK IS FOR T-24 ENERGY CALCS.  Variance was submitted to seperate the fire life safety system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55537	16041-30000-26313	12628 N AMBOY AVE	91342	7	219B145    37	2604015021	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Expired	09/21/2018 12:00:00 AM	ADDRESS	34.30082	-118.47175	"""0$ permit fees due to senate bill 1222""PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55538	19041-20000-23816	5550 N TOPANGA CANYON BLVD STE 300	91367	3	174B101   285	2146007119	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.17162	-118.60554	T24 PLAN CHECK FOR EXISTING COMMERCIAL BLDG STE 300. LIGHTS ONLY. TOTAL SQUARE FOOTAGE  = 2073 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55539	12041-20000-08976	15301 W LANARK ST 1-87	91406	6	189B145    72	2654037082	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	PIN	34.21812679	-118.46686872	Fire alarm system. Low rise Senior Apartments. Plan check for fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55540	15041-20000-41018	631 E 24TH ST	90011	9	120A207   116	5127008009	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.02382	-118.26128	PV1 rooftop solar installation 3.8kW AC system(14)SE F720-KZC-2Y(1) inverter: SE3800A-USpower optimizer SE P300standard plan is used	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55541	18041-30000-02590	4847 W OAKWOOD AVE	90004	4	138B193   216	5522030003	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			01/23/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	34.0774	-118.31305	Plan check for new fire alarm system for 49 units appartment. Total Fire alarm devices: 188 and 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55542	13041-20000-23185	12168 N YOUNGDALE AVE	91342	7	216B149   102	2611020002	RS-1	North Valley	Sylmar	Sylmar	YES	1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.29158	-118.45757	ROOF MOUNTED SOLAR, FEES HAVE BEEN CAPPED. FINAL FEE PERIOD NO CHARGE.New 12.25kw Roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED.  Plan check and permit are for the PV system only, NOT for main service upgrade or derating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55543	11041-10000-00855	2414-2416 W JAMES M WOOD BLVD Bldg A/B	90006	1	132A201   279	5136002031	C2-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM			Corrections Issued	01/14/2011 12:00:00 AM	PIN	34.05479598	-118.28256063	CHANGE OF USE FROM PRINTING SHOP TO CHILDREN DAY CARE  (8,288 SQ FT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55544	19041-10000-02831	8340 N VAN NUYS BLVD STE A	91402	6	192B149   292	2638022061	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.22301	-118.44856	TENANT IMPROVEMENT in the DD'S DISCOUNTS STORE ;NEW 800A  TENANT PANEL INSTALLED TO SUPPLY OTHER NEW ELECTRICAL EQUIPMENT .PLAN CHECK IS FOR POWER AND LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55545	18041-10000-03380	4528 W BRAZIL ST SUITE D	90039	13	165B205    89	5593011004	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.14674	-118.27336	REPLACE MH LUMINAIRES INDOOR WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55546	15041-10001-02101	12180 W MILLENNIUM WEST	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	Supplemental application for plan check only.  Title 24.  Changes to approved set.  New fixture type and arrangement.*****Previous Work Description*****Plan check for Title 24 only. Project is the ground floor lobby. Total lighting area = 1,686 sq. ft. 2008 compliance forms have been used as the building permit was submitted before 7/1/2014. Plan check for power, outdoor lighting, and the rest of the indoor lighting is under application 14041-20000-06257.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55547	13041-10002-26030	12411 W FIELDING CIR Block 7	90094	11	105B161  1220	4211034054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	33.97968	-118.40871	DELTA 14 CHANGES TO SERVICES SINGLEL LINE DIAGRA; CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA 14PLAN CHECK FOR POWER AND ENERGY.  BLOCK 7 OF PLAYA VISTA PROJECT. ELECTRICAL INSTALLATION FOR MULTI-FAMILY 4-STORY OVER PODIUM; 5 SERVICES (SERVICE 1,2,3,4,5), LOCATED IN METHAN ZONE, METHANE DESIGN LEVEL 1.  (2) GENERATORS INSTALLED. TOTAL 703 UNITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55548	18041-10001-20550	642 N SAINT CLOUD ROAD	90077	5	144B153   881	4362017050	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	12/23/2021 12:00:00 AM	ADDRESS	34.0872	-118.44004	Supplemental Plan Check and permit for new guest house building, connected to new single family dwelling. Add new panelboards to existing service at the main house (plan approved under separate submittal)BUILDING PERMIT # 15010-10000-02172	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55549	14041-10000-24902	355 E 1ST ST	90012	14	129A215    13	5161012903	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.04958	-118.23946	Fee estimate only for title 24 plan check; new load and equipment have been added on the plan and the load may be more than 400 amp. plan check engineer need to request for confirmation of new  load added in case  suplimental application neededfor power plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55550	12041-10000-28399	5460 N NOBLE AVE	91411	2	174B145   678	2250012031	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.1703	-118.46162	New 3.74 kw roof mounted PV for a single family. X-formerless INV with optimizer.(PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55551	11041-10000-04859	322 N BROAD AVE	90744	15	027B209    29	7418025021	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM			PC Approved	03/11/2011 12:00:00 AM	ADDRESS	33.77349	-118.26046	T-24 ENERGY CALCS IN A ATM ROOM IN A COMMERCIAL AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55552	15041-20000-22910	6201 W HOLLYWOOD BLVD ste 126	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	Plan check for power and Title-24 (energy).  Total area = 13,342 sq. ft.  T.I. to existing commercial first time tenant.  New power distribution system.  Installation of lights and power outlets.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55553	16041-20000-04944	15733 W HAYNES ST	91406	6	180B141   560	2233003046	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	PIN	34.18944964	-118.47614197	Plan check for PV roof mounted system. System size: 6.0kW with 26 modules and 1 inverter(6.0kW) Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55554	14041-10001-27747	5400 N BALBOA BLVD	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	PIN	34.16914714	-118.50029545	ROOF-MOUNTED PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55555	13041-10000-09075	5931 N OAKDALE AVE	91367	3	177B113   221	2153016021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM			Reviewed by Supervisor	05/02/2013 12:00:00 AM	ADDRESS	34.17834	-118.56589	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SIZE 13.47 KW. USING 55 PANELS. THREE TRANSFORMERLESS INVERTERS AND LOAD CENTER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55556	14041-20000-08631	912 E 3RD ST	90013	14	129A215   298	5163015022	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.0458	-118.23462	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO THE FIRST AND GROUND FLOOR OF SUITE 103. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS. 16398 SQFT. EMERGEGENCY LIGHTING IS EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55557	18041-10000-04298	611 N HENRY FORD AVE	90744	15	030B213   374	7440001912	[Q]M3-1	Harbor	Port of Los Angeles			2947.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	33.77781	-118.24174	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55558	16041-10002-08351	524 E WASHINGTON BLVD	90015	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM			PC Approved	02/13/2017 12:00:00 AM	ADDRESS	34.0283	-118.25963	CHANGE TO APPROVED SET OF PLANS. CHANGES TO RACKING SYSTEM TYPE TO ANOTHER BRAND. RECHECK FOR UL COMPLIANCE 2703 PV RACKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55559	18041-10000-23889	1129 W 37TH ST 1-5	90007	8	120B197  1111	5040030019	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			06/26/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.02108	-118.29263	Energy plan check for a new (3) story (5) unit apartment outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55560	18041-10002-13577	634 N KINGMAN AVE	90402	11	124-5A133 150	4408036007	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.03522	-118.50854	SUPPLIMENTAL FOR THE ENERGY STORAGE SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55561	15041-20001-09948	12048 W RYNGLER ROAD	91604	2	162B165   694	2369019028	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	34.13966	-118.39349	expedited per applicants requestpv1. addition to an existing system. system total size; 9kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55562	19041-10000-53509	142 E VERNON AVE	90011	9	112-5A205  87	5109001007	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Zapata-King		2285.00	Electrical	Electrical	Apartment			12/27/2019 12:00:00 AM			PC Info Complete	05/18/2022 12:00:00 AM	ADDRESS	34.00363	-118.27312	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW 1000A SERVICE (120/240 3P,4W) FEEDIN A NEW 1000A DISTRIBUTION SECTION THAT CONTAINS ALL DOWNSTREAM SUBPANELS (DWELLING UNITS), SERVICE ALOS FEEDS OTHER ASSOCIATED HOUSE LOADS AND EQUIPMENT. TOTAL AFFECTED AREA IS 10,330 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55563	16041-10002-44408	750 S GRAND AVE #30	90017	14	129A209   250	5144012058	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	34.04628	-118.25721	Changes to approved set under delta 2. Plan check only.Scope includes replacment of emergency and exit lights from unit equipment to emergency panel to reflect connection on the field.New luminaires rated for 277V.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55564	16041-10000-15669	16027 W VENTURA BLVD 301	91436	5	168B141   538	2261022106	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.15641	-118.48225	NEW TENANT IMPROVEMENT ON (E) OFFICE AREA STE. 301. NEW CONNECTED LOAD < 400A. PC FOR T-24 ONLY. TOTAL AREA: 6,560 SQ.FTB# 16016-10000-07151	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55565	18041-10000-47838	402 W ANAHEIM ST	90744	15	030B205   434	7416028005	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.7796	-118.26666	REMOVE HID INDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55566	15041-20001-13947	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.20696	-118.3417	06/19/2015 Changes to an approved set of plans. Changes include the addition of (4) devices.*****Previous Work Description*****PC FOR FIRE ALARM SYSTEM. TOTAL OF 212 DEVICES. NEW FIRE CONTROL PANEL. ASSOCIATED ANNUNCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55567	11041-20000-03795	116 N ROBERTSON BLVD 9th Floor	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM			PC Approved	03/21/2011 12:00:00 AM	ADDRESS	34.0758	-118.38356	Plan check for T24 Energy (general/emergency) lighting on the 9th floor. Permit under #11041-90000-04331	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55568	16041-20000-34284	11618 W VALERIO ST	91605	11	186B169   704	2316028008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.20472	-118.3852	pv1install roof mounted pv system sized 7.5kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55569	19041-20000-31257	11421 W CANTON DR	91604	2	159B169   239	2377010014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	03/25/2021 12:00:00 AM	ADDRESS	34.13373	-118.38252	Install 27 kWh energy storage system, associated distribution, and 200A main panel upgrade.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55570	19041-10000-07586	2132 E 7TH PL	90021	14	124-5A217 351	5166003006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	05/05/2020 12:00:00 AM	ADDRESS	34.03336	-118.22873	FULL PLAN CHECK FOR POWER AND ENERGY FOR A  T.I. TO RESTAURANT. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES AND LIGHTING. MODIFICATION OF TEMPORARY POWER CONNECTION FROM TWO ADJACENT BUILDINGS.  TOTAL AFFECTED AREA IS 8667 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55571	17041-10000-31817	15430 W ROSCOE BLVD	91406	6	192B145   435	2654036032	[T][Q]CM-1VL	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.22119	-118.469	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 76625 SQ. FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55572	13041-20000-10724	19313 W STARLIGHT DR Pv-1	91356	3	168B117    31	2175003014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.16033	-118.55442	PV-1. Plan check for addition to existing PV system. Addition of a 3kW inverter. Existing 225A service. loads calcs provided for downgrade breaker	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55573	15041-20001-29012	19809 W PRAIRIE ST	91311	12	198B113   115	2761040023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.23925	-118.56529	Expedite fees only.     Installation of new roof mounted solar PV array.  This is a feed-in-tarif project.  Total system size = 140 kWac.  540 PV modules are being connected to 7 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55574	12041-20000-25305	14526 W HARTLAND ST	91405	6	183B149   674	2219025027	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			10/22/2012 12:00:00 AM			Verifications in Progress	01/17/2014 12:00:00 AM	ADDRESS	34.19496	-118.44984	NEW 22-UNIT, 3-STORY APT. BUILDING.   New 1600 Amp Service.  Full Plan Check.  Not a Methane Zone.  Variance will be filed to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55575	15041-20000-10163	3354 N WRIGHTWOOD DR	91604	2	159B173   356	2380038008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM			Reviewed by Supervisor	04/28/2015 12:00:00 AM	ADDRESS	34.13238	-118.37327	Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (55) micro-inverters, (55) modules, and (1) 125-amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55576	13041-10000-26018	380 WORLD WAY T 53R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Installation of 4 ea self-illuminated signs LED at the tenant space Coach at the TBITSIGNS WILL BE CONROLLES BY A California Energy Certified time clock.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55577	17041-10000-41773	6728 N TROOST AVE	91606	2	180B169   166	2320013008	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Apartment			11/17/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	34.19306	-118.38648	PC for new 3.8kW PV system for rooftop solar. Installing 10 modules with optimizers and one central inverter. System is connected to seperate existing 100A panel. Inspector to verify rating of existing 100A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55578	13041-10000-36184	161 S AVENUE 49	90042	1	148-5A227  54	5467012015	R3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.20	Electrical	Electrical	Public Safety Only			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.10172	-118.20126	fire alarm with central station monitoring at charter school with 4 classrooms and offices and restrooms-single floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55579	14041-10000-17361	12510 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	33.97839	-118.4121	PLANCHECK FOR METHANE MITIGATION.  1 PANEL AND 27  DEVICES.14010-10000-01301 . NEW Type VA  6-unit  4-story  APARTMENT BUILDING with attached parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55580	17041-10000-07756	9330 N WINNETKA AVE	91311	12	198B113   108	2761040027	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.24019	-118.5708	PC for energy only. Removing and replacing HID fixtures with new LEDs for indoor use. Area: 26,400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55581	18041-10000-41771	8500 W BEVERLY BLVD #654	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGE USE/OCCUPANCY OF 6TH FLOOR MALL TENANT SPACE (916 SF) FROM RETAIL TO TAKE-OUT COFFEE SHOP & TENANT IMPROVEMENT. (N) CEILING, (N) FLOORING, (N) INTERIOR, (N) LIGHT,(N) NON-BEARING PARTITIONS; (E) REMODEL ADA GENDER RESTROOM. NO SEATING PROVIDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55582	18041-10003-23086	977 N NORTH BROADWAY	90012	1	136-5A215 263	5414007022	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	34.06611	-118.23652	SUPPLEMENTAL FOR CHANGES TO APPROVE SET, PLAN CHECK ONLY, DELTA 2 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55583	12041-10000-26102	613 S GAYLEY AVE	90024	5	135B149   241	4363006020	[Q]R4-1VL	West Los Angeles	Westwood			2653.05	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.06762	-118.44862	Plan check new fire alarm system for fraternity house with 23 bedrooms over parking garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55584	14041-20000-13204	6644 N COLDWATER CANYON AVE	91606	2	180B161   377	2325006021	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.19162	-118.41362	PV1. ROOFMOUNTED SOLAR SYSTME. NON STANDARD PLAN. MICROINVERTER. SYSTEM SIZE: 2.65 DC.(10) SUNIVA 265W MODULES.(10) ENPHASE M215 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55585	12041-20000-11799	2476 W LOY LANE	90041	14	162A219    96	5683025035	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM			Reviewed by Supervisor	06/15/2012 12:00:00 AM	ADDRESS	34.13944	-118.2213	pv system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55586	19041-10000-24323	1641 S PREUSS ROAD	90035	5	129B169   717	4305020900	OS-1XL-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	07/31/2020 12:00:00 AM	ADDRESS	34.04927	-118.38467	New Fire Alarm System with 28 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55587	10041-20000-16395	8732 S READING AVE #1-11	90045	11	096B169   627	4125016012	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM	01/18/2012 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	33.95901	-118.3814	New 11 units 4 story apartment building. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55588	17041-20001-11125	805 S MESA ST	90731	15	015B201   315	7455007021	R4-2-HPOZ	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	33.73671	-118.28586	expedite.pv2install roof mounted pv system sized 34.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55589	16041-10000-45683	22001 W NORDHOFF ST	91311	12	198B101   298	2727021024	(T)(Q)RD3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Issued	01/19/2017 12:00:00 AM	ADDRESS	34.23556	-118.60629	PC for energy only (outdoor) for private property. Total affected area: 57,942.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55590	19041-10001-23373	612 S BROADWAY	90014	14	129A211   216	5144002019	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM			PC Info Complete	11/06/2019 12:00:00 AM	ADDRESS	34.0462	-118.25221	Changes to an approved set of plans. All changes are clouded under delta X. Changes include removing 277V fixtures and replacing them with 208V, and revising panel schedules for lighting fixture loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55591	11041-20000-07074	1607 S PACIFIC AVE	90291	11	106-5A143  28	4226009022	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM			PC Info Complete	05/24/2011 12:00:00 AM	ADDRESS	33.98735	-118.47224	Install general/emergency lighting for a restuarant.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55592	09041-20006-24366	3327 E SABINA ST Bldg A	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			11/22/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 6 Revision to approved plans for New Apartment Complex w/ multiple buildings (Bldg A) 1of 2 Building. Panel schedules changes to match as built condition	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55593	14041-20000-04124	7742 N AMESTOY AVE PV1	91406	6	189B133   819	2203007014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.21161	-118.50537	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PNL. UNGROUNDED SYSTEM, SIZED @ 4.25 kW DC, WITH (17) TRINA #TSM-250PA05.18,  (17) OP300 OPTIMIZERS, (1) SOLAREDGE SE3800-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55594	11041-20000-24076	800 W WILSHIRE BLVD #1080	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM			PC Approved	11/09/2011 12:00:00 AM	ADDRESS	34.0493	-118.25841	PLAN CHECK ENERGY/EMERGENCY TENANT IMPROVEMENT WITHIN SUITE #1080	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55595	16041-20001-19809	433 S WESTMORELAND AVE	90020	5	132B153   800	4324006020	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/06/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.06559	-118.28861	EXPEDITEPV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 64KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55596	15041-20000-41786	10250 W CONSTELLATION BLVD 30TH FLR-CORRIDOR	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON 30TH FLOOR (CORRIDOR/HALLWAY  SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL  AFFECTED AREA IS 1495 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55597	12041-20000-25406	11017 W VENTURA BLVD # 216	91604	2	162B173   458	2366023013	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.14084	-118.37075	T-24 for beauty salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55598	15041-10000-34603	10340-10378 N SEPULVEDA BLVD bldg 3	91345	7	204B145   201	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.2586	-118.46705	PC FOR POWER AND ENERGY.  NEW 3500A SERVICE. CHANGE OF USE FROM COMMERCIAL TO RESTURANT. PART OF THE JOB IS FOR SHELL. CAHSE BANK AS EXISTIN REMAINS. TOTAL AREA 3760 SQ FT(OUTDOOR LIGHTING) PLUS 696 SQ FT(INDOOR).B# 15018-10000-21181.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55599	12041-20002-25389	22333 W SHERMAN WAY	91303	3	183B101     5	2023028044	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.20119	-118.61325	Changes to previously approved set of plans. Plan check for energy only. Delta 2 changes.T-24 LIGHTING PLAN CHECK FOR ADDITIONAL LIGHTING TRACK IN SALES AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55600	13041-10000-24096	2920-2930 W ROWENA AVE BLDG 6	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.10823	-118.26884	TOWN HOUSES BUIILDING 6 OF 6. SERVICE SIZE IS 600 AMPS. 10 DWELLING UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55601	15041-10000-18700	437 S BROADWAY	90013	14	129A211    47	5149026008	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Expired	12/13/2017 12:00:00 AM	ADDRESS	34.04875	-118.25034	Full plan check for an existing 4-story building; The main scope is for core/shell only, work include new HVAC units, minimum lighting and receptacle outlets. Note. Applicant comes in with a preprint check. plan checker need to add (20) circuits for final fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55602	14041-20001-07472	7727 W FORSYTHE ST	91042	7	208-5A195 154	2557001030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM			PC Approved	05/08/2014 12:00:00 AM	ADDRESS	34.26607	-118.30118	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55603	18041-10000-00657	718 N ARAGON AVE	90065	1	145-5A219 365	5453020010	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.09164	-118.22187	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWdc / 2.80KWac.(10)MODULES-SOLARWORLD SW-300 MONO(10)MICROINVERTERS-ENPHASE S280-60-LL-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55604	15041-10001-27725	11261 N EL DORADO AVE	91331	7	210B153   267	2616021057	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.27433	-118.43434	(((EXPEDITE FEES)))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.2KWAC. 47 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55605	15041-10007-35073	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES UNDER DELTA 41.SCOPE INCLUDES ADDITION OF LUMINAIRES, REVISION ON TITLE 24 FORMS AND ADDITION OF EQUIPMENT AND CIRCUIT.REMOVAL OF CU-721-B FROM PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55606	16041-20000-31340	20740 PLUMMER ST	91311	12	198B109    48	2748002032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	PIN	34.24217305	-118.58551034	New mixing room and weight room in (E) warehouse.  Plan check for energy only.  1252 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55607	12041-20000-27126	22710 W NAPA ST	91304	12	192B097    40	2004015029	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.22585	-118.6221	PV-1. Plan check for PV system. microinverters. 6.4 kW. FEE FOR MONITORING SYSTEM HAS BEEN INCLUDED IN PERMIT FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55608	13041-20002-26892	11651 W SAN VICENTE BLVD	90049	11	132B145   503	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.05412	-118.46401	changes to approved set of plans. change to lighting. pc for new T24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55609	13041-10001-35686	20140 W DELITA DR	91364	3	171B113   241	2166010020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/29/2014 12:00:00 AM	ADDRESS	34.16494	-118.57323	Expedited RSES plan check per applicant request. {{PV1, Install 8 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US. (32) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55610	18041-10000-48481	523 W 6TH ST SUIT 616	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.04864	-118.25484	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT FOR (E) OFFICE, INCLUDING DEMOLITION OF (E) PARTITIONS, NEW NON-BEARING PARTITIONS, LIGHTING AND FINISHES, TOTAL 3660 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55611	19041-20001-50859	24351 W PHILIPRIMM ST	91367	3	174B089   482	2046010011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM			PC Approved	01/14/2020 12:00:00 AM	ADDRESS	34.17148	-118.65558	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 15.525 KW DC/14.079 KW AC CEC. SCOPE OF WORK CONSISTS OF (45) PV MODULES WITH OPTIMIZERS, A 125A LOAD CENTER, AND (1) 6 KW INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55612	13041-20000-21145	23150 W DOLOROSA ST	91367	3	174B093   508	2042007049	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	08/15/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.16992	-118.63149	New Roof mounted PV using Enphase Microinveters.  Plan check and Permit are for the PV system only, NOT for any service upgrade or Main Service Breaker changes.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55613	18041-20000-47177	4536 E BEND DR	90065	1	153A221   386	5475018026	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.11216	-118.22032	Plan check for a PV1 roof-mounted PV system. System size is 5.76 kWdc/5.12 kWac and consists of (16) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55614	17041-20000-26760	18611 W BRYMER ST	91326	12	213B125   145	2872019031	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.28251	-118.5386	Plan check for a PV1 roof-mounted PV system. System size is 4.6 kWac and consists of (1) inverter and (17) modules. PV interconnection is being made onto a center-fed panelboard.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55615	12041-10000-03750	888 S FIGUEROA ST #100	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM			PC Approved	02/21/2012 12:00:00 AM	ADDRESS	34.0465	-118.26225	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR BANK AT BASEMENT, FIRST FLOOR AND MEZZANINE OF SUITE #100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55616	18041-20001-47800	15131 W WEDDINGTON ST pv1	91411	4	172-5A147 137	2250004025	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM			PC Approved	01/02/2019 12:00:00 AM	ADDRESS	34.16744	-118.46294	01-02-2019 Changes to an approved set of plans, Changes include remove sub-panel. All changes has been clouded. plan check onlyFees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55617	14041-20000-34371	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	03/20/2015 12:00:00 AM		Issued	03/20/2015 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check for energy only. TI to an general use office in a medical building. Approx. 10,000sqft. New lighting and relocation of existing lighting in space. New receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55618	13041-10000-28553	6255 W SUNSET BLVD 7TH FLOOR	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	TITLE 24 ENERGY PLAN CHECK ONLY. HIGH RISE. OFFICES. CHANGES TO COMMON AREAS. 7TH FLOOR. OTHER FLOORS ARE ALSO BEING DONE ON DIFFERENT APPLICATIONS #'S. 1209 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55619	17041-30000-33482	2029 S CENTURY PARK EAST #415	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing high-rise building T.I. office building space. Total area: 632 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55620	17041-10000-25669	13209 N GLADSTONE AVE	91342	7	225B157   700	2509016019	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.31092	-118.42879	TITLE 24 PLAN CHECK TO REPLACE EXISTING (25) FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA = 249100 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55621	15041-10000-28093	1831 S SAWTELLE BLVD 1-10	90025	11	126B149   385	4261021024	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Public Safety Only			08/26/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.04294	-118.4457	new fire warning system for 30 units apt bldg	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55622	17041-20000-11189	3535 S LA CIENEGA BLVD	90016	10	120B173   388	4205028002	[Q]C4-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.02292	-118.37248	ti to an existing commercial building (target).  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 120460.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55623	15041-20000-24723	19738 W WINGED FOOT WAY	91326	12	216B117   160	2701026009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.28734	-118.56405	Installation of new roof mounted solar PV array.  Total system size = 6.665 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55624	11041-10001-20621	1088-1092 E ELKGROVE AVE BLDG 23	90291	11	111B145   234	4243001038	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/10/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.00285	-118.45953	LINCOLN PLAZA APARTMENT BUILDING PROJECT(((((((   7-10-2014   M.Z   addition of three 2 amps car chargers. )))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55625	14041-10000-14924	4534 N VAN NOORD AVE	91604	2	168B161  1071	2362006005	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.15323	-118.41483	PV1, INSTALL 4.335 ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFPORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55626	14041-20001-02277	17100 W CALAHAN ST	91325	12	198B133   591	2692019030	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.23631	-118.50588	(((expedite fees)))pv1 single family dwelling. total system size 11.4 kw ac using 3 transformerless inverters nonstandard plan. using power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55627	14041-10000-03184	777 S FIGUEROA ST SUITE 1390	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.04828	-118.26116	Tenant improvement for office suite in an existing commercial highrise building.  Title 24 plan check for changes to interior lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55628	14041-20000-19334	20750 W VENTURA BLVD	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.16638	-118.58506	Restroom remodel on 1st floor of (E) 4-story commercial office building.  Plan check for energy compliance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55629	18041-20000-39313	17430 W CHATSWORTH ST	91344	12	207B129   498	2733019017	CR-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.26459	-118.51435	Change of use from SFD to medical office.  Plan check for power and energy.  New 400 amp service.Building permit under 18014-20000-04558	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55630	14041-20000-28698	9899 N AMBOY AVE	91331	7	201B157   167	2622018012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.25005	-118.42022	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 3 STRINGS. TOTAL OF 18 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55631	19041-20000-48877	521 E BOCCACCIO AVE	90291	11	108B149  1522	4237007008	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	33.98877	-118.45821	Fire sprinkler monitor panel.  (1) FACP with annunciator and (5) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55632	19041-10000-32274	602 N BROAD AVE	90744	15	030B209   564	7423013012	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.77736	-118.26074	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55633	15041-20001-32028	16621 W NORDHOFF ST	91343	12	198B137   973	2687024006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM			Reviewed by Supervisor	10/06/2015 12:00:00 AM	ADDRESS	34.23587	-118.49459	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 15.2KW AC USING 2 CENTRAL INVERTERS WITH 62 MODULES IN TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55634	18041-10000-47265	321 W OLYMPIC BLVD SUITE E	90015	14	127-5A209 231	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM			Reviewed by Supervisor	12/24/2018 12:00:00 AM	ADDRESS	34.04211	-118.25895	FULL PLAN CHECK FIRST TIME TENANT POWER AND ENERGY IN MEDICAL FACILITY. SCOPE INCLUDES ADDING TWO NEW PANELS TO EXISTING 2000A METER. TOTAL EFFECTED AREA 2033SQFT.BL#18016-10000-38995	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55635	15041-10000-42782	508 W BERNARD ST	90012	1	136-5A215 154	5414006029	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM			PC Approved	12/18/2015 12:00:00 AM	ADDRESS	34.06723	-118.23769	Energy plan check only for an commercial T.I (Nest Studios) ; Scope includes new lighting and receptales. Total area 1260 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55636	17041-10000-01754	4016 S CENTRAL AVE	90011	9	115-5A209 248	5114033033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Closed	01/11/2024 12:00:00 AM	ADDRESS	34.01063	-118.25627	FULL PC FOR POWER AND ENERGY FOR A NEW MINARET STRUCTURE (BLDG 3 OF 3, ONE SET OF PLANS SUBMITTED). SCOPE INCLUDES NEW PANELS AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 35079 SQ. FT. B#16010-10000-03365	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55637	14041-10000-29140	7605 N LOUISE AVE	91406	12	186B133   190	2202009009	C2-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Apartment			10/21/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	PIN	34.20870027	-118.51021237	Plan check for fire alaram system. (80) new devices and (3) new fire alarm panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55638	15041-20001-27377	14534 W SATICOY ST 1-26	91405	6	186B149   214	2218003015	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			PC Approved	08/29/2015 12:00:00 AM	ADDRESS	34.20831	-118.45021	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55639	18041-10000-32517	1320 N LAKE SHORE AVE	90026	13	141A209   702	5419031013	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1974.20	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.07876	-118.2599	TI IN AN EXISTING COMMERCIAL SPACE (GYM). T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55640	16041-30000-16309	12400 W SANTA MONICA BLVD	90025	11	126B145   919	4267031003	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.03888	-118.46666	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,687 sq. ft.Note: Building permit has been pulled under 15016-30000-11624	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55641	10041-10000-02808	954 E SEASIDE AVE DIVE HOUSE	90731	15	018B201   130	7440026903	M2-1, [Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Public Safety Only			02/17/2010 12:00:00 AM	02/17/2010 12:00:00 AM		Permit Finaled	03/30/2010 12:00:00 AM	PIN	33.7478016	-118.27948576	NEW FIRE WARNING SYSTEM AT THE DIVE HOUSE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55642	16041-10001-27719	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Closed	04/18/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES TO NUMBER OF DEVICE COUNT, REVISION TO FLOOR PLAN AND ADDITION OF MORE MODULES FOR DUCT DETECTORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55643	14041-10000-23500	4045 N CARTWRIGHT AVE	91604	2	162B177   202	2423033007	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.14266	-118.36397	Installation of roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55644	16041-10000-17973	4400 S METTLER ST	90011	9	112-5A207  74	5109015013	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	07/16/2016 12:00:00 AM	ADDRESS	34.00373	-118.26636	PV1. NEW SOLAR SYSTEM ON EXISITNG RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.18KWdc / 3.0KWac. (12)MODULES-KYOCER#KU2656ZPA(1)INVERTER-ABB# PVI-3.0-OUTD-S-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55645	14041-10000-09650	16238 W RAYMER ST	91406	6	189B137    19	2205029037	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.21771	-118.48681	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55646	14041-10001-16519	9034 N BURNET AVE	91343	7	195B145   635	2654006027	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.2348	-118.46302	Changes to an approved set of plans. Changes include the addition of a 200-amp rated panel and the change of mechanical units from single phase to 3-phase. All changes have been clouded and marked as Delta 1.*****Previous Work Description*****Full plan check for power and lighting.  Total area = 25,899 sq. ft.Construction of new public charter middle school and site development. fire alarm variance has filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55647	13041-10000-26385	18252 W BERMUDA ST	91326	12	207B125   179	2715010019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.2661	-118.53144	PV1.  Install 6.75 kW DC roof-mounted solar array, interconnect with main service panel.  Central inverter: Fronius IG 5100 NEG.  27 modules: Trina Solar TSM-250PA05.18	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55648	14041-10000-00424	3325 W WILSHIRE BLVD SUITE 101	90010	10	135B197  1123	5502027010	C4-2, R5-2, R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	ADDRESS	34.06195	-118.2949	Office suite TI for Uniti Bank, 1887 sq ft.  Title 24 plan check only for changes to lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55649	18041-10000-12412	1057 N KINGSTON AVE	90033	14	132A223    54	5201016023	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.05714	-118.20965	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55650	17041-10000-32271	5889 S TOWNE AVE	90003	9	105B205    96	6006030017	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	07/07/2018 12:00:00 AM	ADDRESS	33.98743	-118.26761	PC FOR PV SYSTEM USING 11 MODULES AND CENTRAL INVERTER SYSTEM. 3.8KW WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55651	17041-20000-21776	6420 W WILSHIRE BLVD 15th Floor	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for energy only. TI to to corridor and elevator lobby on 15th floor of high rise building. New lighting (incl. emergency) - 1,050sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55652	13041-10000-32242	1340 W 35TH ST	90731	15	009B193  1035	7470021022	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.71759	-118.30693	PV1, Install 3.25 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 13 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55653	13041-20000-00204	3835 W FRANKLIN AVE	90027	4	148-5A203  91	5433015022	R1-1	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	ADDRESS	34.10235	-118.27601	New 5.39kw rooftop mounted PV system for an existing single family residence.  System is ungrounded/transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55654	14041-20000-08114	22608 W GAULT ST	91307	12	183B097   863	2024040011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.19958	-118.61919	PV1 TRANSFORMERLESS SYSTEM USING STANDARD PLAN. TOTAL SYSTEM SIZE 6.0KWAC(26) canadian solar cs6p-250px(1) Power one aurora pvi-6000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55655	16041-10001-33650	3185 E WASHINGTON BLVD	90023	14	117A223    39	5169020003	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.01526	-118.21058	Installation of a roof mounted solar system in a commercial storage building. Installing 12 string inverters rated at 33.3Kw each for a total system size of 399.6 Kw. Installing 1534 solar modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55656	17041-10000-45892	813 N HARPER AVE	90046	5	141B173   148	5529010027	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.0858	-118.36932	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.07KWdc / 3.8KWac.(11)LG 360Q1C-A5(11)OPTIMIZERS-P370 SOLAREDGE(1)INVERTER-SOLAREDGE 3.8H	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55657	13041-20000-08145	7606 N FALLBROOK AVE #10	91307	12	186B097   194	2013008054	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	PIN	34.20860599	-118.62297665	Plan check for energy and emergency lighting. Change of use from cellphone retail to nail salon. Commercial low-rise. Cyn's Pretty Nails. Unit 10.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55658	18041-20000-02199	22160 W VENTURA BLVD	91364	3	171B101   122	2169001044	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	07/07/2021 12:00:00 AM	ADDRESS	34.16836	-118.61018	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. BUILDING PERMIT # 17016-10000-29864	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55659	13041-20001-13991	4446 S TOWNE AVE PV 1	90011	9	112-5A205 190	5109014007	R2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Expired	07/20/2015 12:00:00 AM	ADDRESS	34.00253	-118.26749	(((6/25/2013: CHANGED TO TRANSFORMERLESS INVERTER. 19 MODULES AND 1 INVERTER.)))INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.  4.655 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55660	18041-20001-10510	10828 W VIA VERONA	90077	5	147B145   114	4377037017	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.09911	-118.4588	12/10/2018changes to an approved set of plans.  changes to relocate battery and associated disconnects to exterior wall.this is plan check only.  Plan check for the installation of (2) Tesla PowerWalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55661	17041-10000-05693	14006 W RIVERSIDE DR STE 112	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only in existing space T.I. retail. Total area: 1845 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55662	19041-10000-41830	3910 N KENTUCKY DR	90068	4	159B177    61	2425002025	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	12/22/2020 12:00:00 AM		Permit Finaled	10/24/2023 12:00:00 AM	ADDRESS	34.13552	-118.36293	NEW  APARTMENT BUILDING WITH A PARKING GARAGE. 800 A SERVICE 120-240V. TOTAL AFFECTED AREA 10,208 SQ FT. NO TYPICAL UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55663	18041-10000-40353	14436 W VALERIO ST	91405	2	186B149   578	2217002033	C1-1VL, R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Issued	10/23/2018 12:00:00 AM	ADDRESS	34.20471	-118.44802	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55664	15041-10000-22365	100 WORLD WAY TER1-SPT156R	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR POWER AND ENERGY. NEW SPA IN LAX TERMINAL 1, TOTAL AREA 1000 SQ FT.PER APPLICANT FEE.-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55665	16041-20000-41120	120 S GRANVILLE AVE	90049	11	135B145   691	4401002131	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			11/21/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.06333	-118.47138	Plan check for installation of solar PV system, roof-mounted on aparment building.28kW (14+14) ungrounded system. (96) 310W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55666	15041-20004-16378	940 S FIGUEROA ST basement-5th floor	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.04538	-118.26335	09/27/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the fire pump wiring and fused disconnects.09/12/2016 Changes to an approved set of plans. Changes include the relocation of power equipment to a new electrical room. All changes have been clouded and marked as Delta 4. Note: Building application for the new electrical room is under 14016-10003-1352805/04/2016 Changes to an approved set of plans. Changes have been made to provide power to electrical equipment. Transformer has been added to change voltage class to power said equipment.02/18/2016  CHANGES TO APPROVED SET. ADDITION OF FIREPUMP AND JOCKEY PUMP TO THE SYSTEM REQUIRED BY MECHANIAL*****Previous Work Description*****New service upgrade and distribution equipment for assembly occupancy. new design. This is core and shell clear out of existing building. TI package will be submitted at a later date. per building submittal, PC is accordance to 2008 building efficiency standards.project is in methane buffer zone. NOT A HIGHRISE PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55667	07041-10003-25079	625 S BIXEL ST	90017	1	130-5A207  30	5143024008	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			06/11/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.05322	-118.26286	Application #   07041-10000-25079 status correction, under old app there were 14 panels feeding 76 units, new submittal is for 76 new sub panels and re-routing new branches.(((((((((((((((((((((((((((((((( removed emon demon set up and added 16 new 20 amps circuits. title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55668	17041-20000-02865	1520 W JAMES M. WOOD BLVD System A	90015	1	130-5A205 328	5137004029	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Issued	03/24/2017 12:00:00 AM	ADDRESS	34.05009	-118.27201	pv2install roof mounted pv system sized 15.2kw interconnected with msp.This is system A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55669	15041-10000-32343	333 S ALAMEDA ST STE-300	90013	9	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.04448	-118.23824	Energy plan check for an existing bowling alley area. scope includes new circuits, receptalces and lighting. Total work area is 3790-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55670	11041-10000-00641	3699 S CRENSHAW BLVD	90016	10	117B185   139	5046023011	C2-1	South Los Angeles	Wilshire	Rampart Village	YES	2195.00	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.02001	-118.3354	T-24 and emergency lighting plan check for remodeled office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55671	17041-10000-20169	7166 W FOOTHILL BLVD	91042	7	202-5A199 550	2564001017	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Issued	06/15/2017 12:00:00 AM	ADDRESS	34.24825	-118.28815	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55672	10041-20001-16585	11766 W WILSHIRE BLVD 15th-16th floor	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM			Corrections Issued	11/04/2010 12:00:00 AM	ADDRESS	34.04804	-118.46227	Changes from previously approved plans.  Changes include wattage for some lighting fixture.   Plan check for energy only.*****Plan check T-24 Energy (general/emergency) lighting on 15th and 16th Floor*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55673	16041-10001-21622	13681 W FOOTHILL BLVD	91342	7	222B157    46	2509015027	(T)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM			PC Info Complete	12/30/2016 12:00:00 AM	ADDRESS	34.30865	-118.4315	PLAN CHECK FOR POWER. ENERGY HAS ALREDY BEEN APPROVED UNDER APPLICATION 16041-10000-21622 (INSPECTION IS REQUIRING POWER PLAN CHECK FOR NEW TENANT).EXISTING SERVICE SIZE = 800A - CONNECTECTED LOAD IS SLIGHTLY UNDER 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55674	13041-20000-22771	5432 N HERMITAGE AVE	91607	2	174B165   990	2347013014	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			08/22/2013 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.16958	-118.40019	"NEW 5 UNIT AND 3 STORY APARTMENT BUILDING WITH 600A SERVICE. NOT IN METHANE ZONE.No outside lighting or lighting in the common areas is to be installed per the applicant.""COMPLY WITH DEPARTMENT ORDER effective date07/10/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55675	15041-10000-16743	3320 S GAFFEY ST	90731	15	006B197   260	7467002055	RD2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2976.02	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	33.71388	-118.2927	PV 1, ROOF MOUNTED SYSTEM. 15 MODULES AND 1 INVERTER 3KW. TOTAL SIZE 3.9.(15) KYOCERA #KU2606XPA(1) PV1-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55676	13041-20000-18164	3330 N CAHUENGA BLVD WEST	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.13099	-118.35061	RENOVATION OF OFFICE SPACE FOR CORE, TENANT LEASE SPACE. EMPTY SPACE. PC FOR T24 ENERGY ONLY. EXIT SIGNS AND EMERGENCY LIGHTING INCLUDED. PERMIT already issued under #13041-10000-17510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55677	13041-10000-15218	10530 N DENSMORE AVE	91344	12	207B141   645	2668011005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	07/05/2013 12:00:00 AM	ADDRESS	34.26204	-118.47813	PV1 8.5KW MICROINV 1STORY. NONSTD. ROOFMOUNT.[ 33 MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: 33 m215-60-2LL-S2X]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55678	15041-10000-41062	16321 W KINZIE ST	91343	12	201B137   360	2677023008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.2484	-118.48798	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 22KW INTERCONNECTED WITH MSP.(72) SUNPOWER E20-327(4) SMA SB5000/6000TL INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55679	18041-10000-21817	2601 S FIGUEROA ST Bld #4	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.02804	-118.2763	Fire plan check for an eixising fire alarm system located at the buildig #4 of the same lot of a  multi building structure. All fire alarm system located  in the lot shall interconnced through a same fire alarm system.Total 4 applications under 1 plan including building 1, 4,5 and 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55680	14041-20000-17930	811 W 7TH ST	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.04908	-118.25911	TI to common area restrooms on 3rd and 8th floors of (E) commercial highrise buidilng.  Plan check for Title 24 (2013) for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55681	15041-20000-00087	11938 W RUNNYMEDE ST UNIT B	91605	2	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2015 12:00:00 AM			PC Approved	01/02/2015 12:00:00 AM	ADDRESS	34.20563	-118.39354	Revisions to an approved set of plans. Relocation of the AC disconnect and PV meter from South facing wall to West facing wall. Reference application number: 14041-20000-31863	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55682	16041-10001-28771	1241 S SOTO ST	90023	14	121-5A221 147	5170017030	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.02743	-118.21975	Changes to approved set.  All changes clouded.    Increase inverter size and add 4 new circuits.  Change rooftop playground lighting fixture and add one facade light.  Outdoor Title 24 calculations updated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55683	13041-20000-25180	17631 W VANOWEN ST	91406	6	183B129  1030	2229001017	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.19401	-118.51769	NEW 1600A AND 600A SERVICES. RECONNECTING EXISTING PANELS TO NEW SWITCHGEARS.  ALL LOADS ARE EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55684	16041-10002-30260	157 S FAIRFAX AVE	90036	5	138B177   716	5511025012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.07256	-118.36158	PC for energy only. TI on 1st floor of a 2 story existing office/wholesale building.  Installing new lighting and power. Continuation project for phase 2 on Imax theater. Total sqft = 8099.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55685	13041-10000-30169	16645 W GRESHAM ST	91343	12	195B137   508	2688040037	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.23091	-118.49553	PV1, Install 5.75 kW DC roof-mounted photovoltaic system interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US., power optimizer, 23 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55686	18041-10000-39411	7255 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	33.94208	-118.42063	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55687	13041-10000-31881	545 W 130TH ST	90061	15	081B201   292	6132003019	M2-1VL-O, P-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	33.91464	-118.28459	PV2.  Install 42 kW DC roof-mounted PV system.  168 modules: CENTROSOLAR E250B.  2 inverters: PV1-TRIO-20.0-480.$0 PERMIT IS DUE TO THE 2012 SENATE BILL No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55688	19041-10000-51304	16926 W DULCE YNEZ LANE	90272	11	129B121   854	4419018043	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.04672	-118.54983	(E-PLAN) - CHANGES TO AN APPROVED SETCHANGES INCLUDE RELOCATION OF EQUIPMENT. $0 DUE TO SENATE BILL 1222/1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55689	16041-10000-17752	14006 W RIVERSIDE DR #19	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24, PC FOR ENERGY ONLY.  TI TO AN EXISTING COMMERCIAL BUILDING (RETAIL STORE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1392 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55690	14041-20001-05367	14955 W DICKENS ST 1-18	91403	4	166-5A147  52	2276004011	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			02/26/2014 12:00:00 AM			Reviewed by Supervisor	03/12/2014 12:00:00 AM	ADDRESS	34.15153	-118.45925	((Expedite fees))PV2 NEGATIVELY GROUNDED SYSTEM FOR APARTMENT BUILDING. TOTAL SYSTEM SIZE 12KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55691	13041-20000-29324	333 S GRAND AVE 7TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC AND PERMIT FOR T24 ENERGY LIGHTING. TOTAL AREA 20000 SQ FT. NEW LIGHTING. EXISTING OFFICES. WORK DONE ON 7TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55692	15041-20000-00774	649 E 111TH ST	90059	8	088-5A207 345	6071005019	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	33.93489	-118.26341	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.7KW INTERCONNECTED WITH MSP.(22) HYUNDAI HEAVY INDUSTRIES HIS M250 MODULES(22) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55693	18041-10000-32286	2773 W OLYMPIC BLVD	90006	10	129B197   184	5078007012	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2133.20	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.05282	-118.29388	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55694	18041-10000-48403	4563 W COLORADO BLVD	90039	13	162B205    11	5593012025	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.14233	-118.27364	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55695	13041-10001-01014	9826 N COLUMBUS AVE	91343	7	201B145   289	2656006031	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2013 12:00:00 AM			PC Approved	04/22/2013 12:00:00 AM	ADDRESS	34.24905	-118.46503	Trench relocated along with DC disconnects.  Main service panel main breaker upgraded from 175A to 200A. Permitted under 13041-10000-01014Original Work Description: PV1 9.36KW STD PLAN 1 STORY. 39 MOD ROOFMOUNT. sunnyboy 70000US. TSM-240 PC/PA05. has existing pv system as well.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55696	16041-10000-44086	523 W 6TH ST 11th Floor-Corridors	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Issued	12/16/2016 12:00:00 AM	ADDRESS	34.04864	-118.25484	Plan check for Title 24 only in existing corridor 11 Floor. Total area: 1,630 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55697	14041-10000-03010	11111 W SANTA MONICA BLVD 4TH FLOOR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLANCHECK FOR T24 ENERGY. TI FOR COMMON AREA ON THE 4TH FLOOR( PUBLIC CORRIDORS AND RESTROOMS). 1820.6 SQFT, EMERGENCY LIGHTING. HIGH RISE.  4TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55698	12041-10000-28405	306 W MUSEUM DR	90065	14	148-5A225 170	5467019002	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	34.10027	-118.20744	New 3.84 kw roof mounted PV for a single family. X-formerless INV with optimizer.(PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55699	19041-20000-42591	17952 W KAREN DR	91316	5	168B129   587	2184023002	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.15509	-118.52378	Plan check for PV roof mounted system, PV system size: 11.16KW DC, 10KW AC with 36 PV modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55700	19041-20000-23536	11848 W VANOWEN ST	91605	2	180B169    16	2322014030	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1232.03	Electrical	Electrical	Apartment			06/19/2019 12:00:00 AM	04/15/2021 12:00:00 AM		Permit Finaled	04/04/2023 12:00:00 AM	ADDRESS	34.19367	-118.39165	1200A 208Y/120V 3ph-4w service, distribution, power, and lighting for new apartment building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55701	17041-20000-00355	8843 N DEBRA AVE	91343	12	195B137   457	2688039014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.23153	-118.49073	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55702	10041-20000-19750	8312 W 3RD ST	90048	5	138B173   896	5511031037	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	ADDRESS	34.07258	-118.37052	T.I. for existing space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55703	13041-10000-03069	4700 S HONDURAS ST	90011	9	112-5A213 349	5106010900	OS-1XL	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.00089	-118.24395	3 lighting poles being newly installed in a municipal property park.  T24 OTC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55704	10041-20000-02513	6600 N TOPANGA CANYON BLVD #1012	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM			Corrections Issued	03/15/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	T. I FOR NEW DISNEY STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55705	16041-10000-31345	9448-9462 N TOPANGA CANYON BLVD	91311	12	198B101    79	2746013020	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.24211	-118.60602	TI FOR NURSERY/ OFFICE BUILDING. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55706	18041-10000-29061	1826 N CANYON DR	90028	13	150A191   282	5586029011	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	01/25/2022 12:00:00 AM	ADDRESS	34.10418	-118.31642	PC FOR FOR A SMALL LOT SUBDIVISION PROJECT CONSIST OF 5 UNIT NEW SFD  WITH ATTACHED GARAGE. NEW SERVICE RATED AT 600 120/240V 1PH. SCOPE INCLUDES SUBPANELS AND CIRCUITS. B# 17010-10000-00122, 17010-10000-00124, 17010-10000-00125, 17010-10000-00126, 17010-10000-00127,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55707	11041-20000-17059	19801 W NORDHOFF PL #110	91311	12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM	08/12/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.23568	-118.56464	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55708	13041-10000-21152	12652 W VILLAGE LANE bldg #8	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #8	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55709	13041-20000-29222	9175 N DE SOTO AVE	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.23782	-118.58874	PC FOR T24 ENERGY ONLY. NEW CHIPOTLE. LOAD LESS THAN 400A. TOTAL AREA 2230 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55710	18041-10000-42578	6300 W WILSHIRE BLVD 880	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.06319	-118.36591	TI TO EXISTING OFFICE SUITE (3070SF). INSTALLING NEW AND RELOCATING LIGHTS IN SUITE #880. T-24 ENERGY ONLY.BUILDING PERMIT: 18016-10000-31938	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55711	17041-10001-19500	10388 N SEPULVEDA BLVD	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	PIN	34.25931857	-118.46630746	"first tenant- RESTAURANT - ""JERSEY MIKE"", PLAN CHECK FOR power only;PLAN CHECK FOR TITLE 24 AND PERMIT ONLY WERE OBTAINED ON THE ORIGINAL APPLICATION 17041-10000-19500 FOR THIS TENANT SPACEPLAN check only"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55712	18041-20000-46111	12028 W KESWICK ST	91605	6	186B165   114	2317002036	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.20969	-118.39523	Plan check for PV roof mounted system, system size; 6.67 KW with 21 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55713	13041-10000-29377	14923 W OXNARD ST	91411	6	177A149    85	2242027012	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Info Complete	10/22/2013 12:00:00 AM	ADDRESS	34.17955	-118.45844	REPLACEMENT OF EXISTING 800A SWITCHBOARD TO NEW ONE. WILL BE ADDING 7  NEW SUBMETERS (0-200AMPS) AND 2 SPARES TO BE DISTRIBUTED OUT.  APPLICANT HAS BEEN INFORMED THAT IF FINAL FAULT CURRENT REPORT IS INCREASED FROM PRELIMINARY FAULT CURRENT VALUES, HARDSHIPS WILL NOT BE ACCEPTABLE AND RE-PLAN CHECK WILL BE REQUIRED..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55714	11041-20000-07100	18614 W KIPTON PL	91356	3	165B125    84	2177016008	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	07/08/2011 12:00:00 AM	ADDRESS	34.15176	-118.53762	INSTALL ROOF MOUNTED SOLAR AND INTERCONECT TO MAIN SERVICE PANEL.  UPGRADE SERVICE TO 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55715	10041-10000-08438	680 S WILSHIRE PL	90005	1	132B197   124	5077014041	C2-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM			PC Approved	05/26/2010 12:00:00 AM	ADDRESS	34.06055	-118.28764	TI for a dental office. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55716	14041-20000-11633	17405 W HORACE ST	91344	12	210B129   637	2712006021	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.26984	-118.51336	PV1Install roof-mounted solar array on SFD. System size: 7.41kW(1) SMA America SB3800TL-US-22 transformerless inverter(1) SMA America SB4000TL-US-22 transformerless inverter(33) Suniva OPT260-60-4-1B0 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55717	16041-10001-38798	24728 W WOODED VISTA	91307	12	177B085    30	2032004019	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.1854	-118.66444	02/28/2017 Changes to an approved set of plan. Changes include removed 3 solar modules from 30 modules to  27 modules and the System size from 7.5kW to 6.75kW  . Changes has been clouded	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55718	12041-20000-02694	7518 N DEERING AVE	91303	3	186B105   305	2112007013	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.20699	-118.59654	Install new 800 amp service, optional standby generator, switchboad, subpanels, branch circuits, and lighting for unmanned cable headend facility.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55719	18041-10000-08512	3206 W 8TH ST	90005	10	132B197   490	5094017010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			03/08/2018 12:00:00 AM			PC Info Complete	03/09/2018 12:00:00 AM	ADDRESS	34.05758	-118.29807	PC FOR T-24 ENERGY ONLY.  FOR CORRIDOR TI.SCOPE INCLUDES NEW LIGHTS AND CIRCUITWORK IS DONE ON THE 3RD AND 4TH FLOORS.  TOTAL AFFECTED AREA 1680 SQ.FT. PARTIAL PERMIT PULLED UNDER 18041-10000-06533 FOR RECESS LIGHT (16).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55720	19041-10000-49078	13080 W PACIFIC PROMENADE	90094	11	099B157   479	4211021***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	11/09/2021 12:00:00 AM	ADDRESS	33.97131	-118.42537	PLAN CHECK FOR INSTALLATION OF 34 NEW EV CHARGERS EACH AT 7.2 KW AND 2 NEW SUB PANELTOTAL LOAD: MORE THAN 400 AMPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55721	14041-20001-01339	20530 W WYANDOTTE ST	91306	3	186B109   951	2113022011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.20299	-118.58108	(((Expedite fees)))PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55722	10041-10000-02540	4935 N BALBOA BLVD	91316	5	168B133    61	2258018900	[Q]PF-1XL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.1604	-118.50137	Plan check for new 600A service and switchboard.  Removing 400A existing service and equipment.  No new load added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55723	17041-10000-18444	13540 W DESMOND ST	91331	7	210B157    70	2523005007	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.27544	-118.42731	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55724	19041-10000-07894	6350 N LAUREL CANYON BLVD	91606	2	180B165   762	2334003027	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.18619	-118.39631	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55725	14041-10000-10712	550 S HOPE ST	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.04989	-118.25574	Ti for a high rise blvd. , title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55726	18041-10000-35559	350 S GRAND AVE GROUND-FLR.	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	PLAN CHECK FOR T24 ONLY,  TENANT IMPROVEMENT WORK ON +/- 7525 SQFT. OF THE EXISTING 1ST FLOOR SUITE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55727	19041-10000-42580	707 W WILSHIRE BLVD 43th floor	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.04893	-118.2572	Plan check for energy only. Scope includes adding lighting fixtures and adding receptacles. Total affected area is 515 Sq. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55728	16041-20000-20117	9800 N VENA AVE	91331	6	201B157   301	2621001007	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.24844	-118.42824	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55729	16041-10000-36668	10100 W SANTA MONICA BLVD 1500	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24, PC FOR ENERGY ONLY. FULL FLOOR TI ON THE 15TH FLOOR OF AN EXISTING COMMERCIAL HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 20488 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55730	17041-10000-18876	5370 E ALHAMBRA AVE	90032	14	139-5A235 238	5220031009	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.07649	-118.16861	Full Plan check for a TI renovation on existing office building. Two new services rated at 1600 A and 800A, New panels and equipment. Installing lighting and power. Total area affected area 17,546 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55731	15041-10000-12085	6922 W HOLLYWOOD BLVD	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.10137	-118.34103	Replacement of existing fire alarm system with new Edwards EST3 system in (E) HIGH RISE commercial office building.  Modification of notification devices, adding new initiation devices and monitor modules/relays on the floor plan; scope includes (2) fire alarm panels, (4) power supplies, and (291) fire alarm devices. Approved per F.Y.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55732	19041-20000-51593	10852 W KESWICK ST	91352	2	186B173    52	2409015010	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Issued	12/13/2019 12:00:00 AM	ADDRESS	34.21013	-118.3678	PV1. INSTALL 4.65 KW DC PV SYSTEM WITH (15) MODULES/OPTIMIZERS AND (1) INVERTER (SE50000) CONNECTED ON EXISTING PV SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55733	19041-20000-40989	8225 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	10/04/2020 12:00:00 AM	ADDRESS	34.21902	-118.60624	T24 PLAN CHECK FOR CHANGE OF USE FROM DONUT SHOP TO LAUNDROMAT. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 3128 SFBUILDING PERMIT 19016-20000-32400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55734	19041-10000-32140	600 N GRAMERCY PL 1-13	90004	4	141B193   905	5522008013	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			08/16/2019 12:00:00 AM			Reviewed by Supervisor	09/20/2019 12:00:00 AM	ADDRESS	34.08183	-118.31242	New Four story, 13 unit, Apartment building over garage with a 800Amp Service.Buiding Permit: 14010-30000-01474	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55735	11041-10002-26750	810 S SPRING ST	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM			PC Approved	02/28/2012 12:00:00 AM	ADDRESS	34.04268	-118.25375	Electrical work for future TENANT LEASE SPACE.  Adding new panels, transformers, lighting.  PLAN CHECK for Energy, with Emergency lights approved under App# 11041-10000-26750.((((((((2/28/2012   PREVIOUS PLAN CHECK (11041-10001-26750) WAS FOR 4 RETAIL STORES; THIS ONE IS FOR 3 RETAIL STORES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55736	13041-10000-25852	18805 W BRASILIA DR	91326	12	213B121    84	2872014023	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.28374	-118.54237	PV1. ROOFMOUNTED SOLAR ARRAY. 2 STORY HOUSE. SYSTEM SIZE: 12 KW DC. 1 10KW IG PLUS INVERTER. 48 TRINA SOLAR MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55737	16041-20000-02636	10705 W PENROSE ST Unit B	91352	7	195B177   108	2544027007	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.23241	-118.36447	Plan check for a PV2 roof-mounted PV system. System size is 2.2 kWac and consists of (10) modules, (10) micro-inverters, and (1) load center. Multi-tenant building (3 tenants) will have a total of (3) PV systems interconnecting to it.Note: Solar clearance shall apply to all (3) tenants.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55738	19041-10000-13419	3351 N DREW ST	90065	13	156B213   283	5459009029	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.12093	-118.2419	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55739	18041-10000-35094	9520 N DE SOTO AVE	91311	12	201B109   356	2748023054	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.24345	-118.58835	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55740	16041-10002-17364	1906 W 3RD ST	90057	1	133-5A205  28	5154027029	C2-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.06192	-118.27064	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HOTEL BUILDING. SCOPE INCLUDES NEW LIGHTS FOR COMMON AREAS (CORRIDOR/STAIRWAY). TOTAL AFFECTED AREA IS 9615 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55741	14041-20000-12625	6526 N PENFIELD AVE	91367	3	180B113   575	2134039011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Expired	07/07/2016 12:00:00 AM	ADDRESS	34.18918	-118.56881	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 4.75kW(1) SolarEdge #SE5000A-US-ZB-U transformerless inverter(19) Canadian Solar #CS6P-250PX pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55742	15041-20000-29269	10201 W PICO BLVD Pico-parking	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Issued	03/02/2016 12:00:00 AM	PIN	34.05182951	-118.41257696	PV2 Installation of (1) commercial carport canopy solar PV Power system,(764) modules: sunpower SPR-E20-327-COM(7) inverters: CPS SCA 28KTL-DO/US2 out of 3 sites on the same address.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55743	12041-10000-03551	6290 W HOLLYWOOD BLVD	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM	06/11/2012 12:00:00 AM		Permit Finaled	08/14/2012 12:00:00 AM	ADDRESS	34.10146	-118.32639	NEW STARBUCK'S COFFEE, CHANGE OF USE FROM RETAIL TO RESTAURANT.  No tenant suite number per applicant, stand alone building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55744	17041-10000-34675	820 W COLDEN AVE	90044	8	093A199   129	6054001009	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	33.94893	-118.29021	PC for FA system with one FACP panel, one annunciator and 19 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55745	14041-20001-24848			8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	PIN	33.97582135	-118.28671939	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #5.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55746	16041-20000-10833	18818 W LEADWELL ST	91335	3	186B121   831	2118022015	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.20373	-118.5433	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55747	12041-20001-02382	9310 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.23949	-118.53589	revision added 2 panels and load schedule requested by inspector	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55748	16041-30000-17316	3994 S HILLCREST DR	90008	10	117B181   714	5032010008	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01393	-118.34607	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01103	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55749	17041-10001-40255	950 W WASHINGTON BLVD	90015	1	124-5A203  17	5124016028	(Q)CM-1-HPOZ, (Q)CM-2-HPOZ, (Q)P-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.03731	-118.27895	FEE EXPEDITE PER APPLICANTPV2 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER WITH SOLAR OPTIMIZERS. (33) MODULES, (1)10KWAC INVERTER, TOTAL SYSTEM SIZE IS 10KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55750	12041-10002-02033	10100 S AVIATION BLVD	90045	11	090B173   144	4129029013	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	33.94466	-118.37822	(((SUPPLEMENTAL TO PERMIT # 12041-10000-02033))) New commercial kitchen space, change of use.  New 800A Switchboard and 4 new subpanels, new circuits and loads.  11,450 sq ft of T-24.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55751	16041-10000-35489	6600 N TOPANGA CANYON BLVD SPACE 2016	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL RETIAL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1979 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55752	15041-20001-02915	14752 W ALBERS ST	91411	4	174B149  1103	2249015002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.17012	-118.45489	Expedited per customer request.PV1. Install roof mounted solar system sized 7.6 kW. Interconnected with main service panel.(24) Sunpower E20/327 Modules(2) Sunny Boy 3800 TL Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55753	19041-20000-32404	2957 N ALLESANDRO ST	90039	13	150B213   693	5442025034	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/19/2019 12:00:00 AM	08/08/2023 12:00:00 AM		Issued	08/08/2023 12:00:00 AM	ADDRESS	34.10543	-118.24504	1200A Service, Plan check for power and energy. Total area: 6,607 sq ft. B#18010-20000-04950	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55754	19041-10000-25111	15202 W OXNARD ST	91411	4	177B145   475	2243019011	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.17916	-118.46409	Energy plan check for removing HID fixture and replace with new LED fixture for outdoor lighting with a total area of 3900-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55755	14041-20000-17049	1901 S AVENUE OF THE STARS 15th floor	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.05949	-118.41705	TI to (E) commercial office space.  Plan check for energy for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55756	16041-20000-18364	13827 W SATICOY ST	91402	6	186B153     9	2214019033	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.21009	-118.4341	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55757	10041-10000-08399	6104 N LANKERSHIM BLVD	91606	2	177B169   518	2338005008	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.01	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.18156	-118.38447	T.I. in existing building (Pacheco Vitamim).  Install general and emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55758	13041-10000-11558	6125 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			Reviewed by Supervisor	05/13/2013 12:00:00 AM	ADDRESS	34.09818	-118.32319	AS PART OF THE COLUMBIA SQUARE REDEVELOPMENT, TWO BUILDINGS SHARING  A CONNECTING CANOPY WILL HAVE THE CANOPY REMOVED. A BUILDING PERMIT WAS ISSUED FOR EACH BUILDING-6125 W SUNSET BLVD HAVING 6 FLOORS AND 6121 W SUNSET BLVD HAVING THREE FLOORS. BOTH BUILDINGS ARE UNDER CRA DEVELOPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55759	19041-20000-09824	227-229 N LARCHMONT BLVD	90004	4	138B189   553	5515018017	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.07544	-118.32384	adding new egress lighting and exit signs to (2) existing commercial spaces.  plan check for energy and power.this is plan check only.  permit fees paid under application number 19041-10000-07506	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55760	11041-10000-20866	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	33.94386	-118.4047	new fire alarm system for LAX. 266 devices and 5 panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55761	10041-20000-21566	1880 CENTURY PARK EAST # 100	90067	5	135B161    42	4319001001		West Los Angeles				2679.01	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM			PC Approved	10/28/2010 12:00:00 AM	PIN	34.06321806	-118.4136341	revisie energy calc's	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55762	17041-20001-34454	14321 W JOY DR	91331	6	198B153  1030	2644027242	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24164	-118.44527	Revision to approved set.  Change to higher power module type and inverter rating increased to 3.8 kW AC. (((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.66 KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55763	17041-10001-01145	3219 N ANDRITA ST	90065	13	154-5A213  99	5458016023	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM			PC Approved	02/15/2017 12:00:00 AM	ADDRESS	34.11813	-118.24371	OFF-HOUR PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55764	14041-10000-09744	1517 W 83RD ST	90047	8	099B193  1395	6034014017	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	33.96379	-118.30319	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. USING STANDARD PLAN. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55765	11041-20000-02963	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM	04/28/2011 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT TO EXPAND EXISTING EXAM ROOM AND WORK IN EXISTING OFFICES. (OPTICAL CONTACT LENS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55766	19041-10000-33947	4067 S CLOVERDALE AVE	90008	10	117B177   476	5029039011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.01395	-118.36351	PV1. ADDING AND SOLAR ARRAY TO AN EXISTING PV RESIDENTIAL SYSTEM. ADDING 4.275KWdc / 3.633KWac TO AN EXISTING 7.00KWac pv system. TOTAL SYSTEM SIZE IS 10.8KWac. (17)MODULES- HANWHA 285 WATTS(17)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE HD WAVE 3.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55767	15041-20001-15904	11620 W WILSHIRE BLVD	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	"09-01-2015 Change to approved set of plan. Changes include reuse existing feeder and conduit board(7A) from main switchboard ""MSB2"" to the 75KVA transformer and reuse existing panel(7A). Changes apply to delta 2 only. {{{{{Plan check for power and Title-24.  Total area = 2,723 sq. ft.T.I. to medical office.  Two new panels connected to step down transformer.  Lighting and recepticles.}}}}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55768	12041-10000-04102	783 W GATUN ST Pool-Building	90731	15	021B197  1088		[T][Q]C2-1, [T][Q]RD1.5-1	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	33.75748	-118.29434	Plan check T24 Energy for Pool Building located in Harbor Highlands gated homes. Outdoor lighting around pool area exempt from T24 calculations. Permit for panel and branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55769	11041-10000-17214	12840 W MOORPARK ST	91604	2	165B161   378	2375007075	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM	10/31/2011 12:00:00 AM		Permit Finaled	12/09/2011 12:00:00 AM	ADDRESS	34.15021	-118.41287	NEW ROOFTOP PV SYSTEM FOR AN EXISTING APARTMENT BUILDING WITH 3 8KVA INVERTORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55770	17041-10000-13673	9830 N RESEDA BLVD BLDG A	91324	12	201B125   137	2764001013	R3-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Apartment			04/26/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.24936	-118.53579	PC for 1 replaced FACP panel for fire alarm system in building A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55771	17041-10000-44996	7051 W WILLOUGHBY AVE	90038	4	144B181   804	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.08719	-118.34309	PC FOR WAREHOUSE TI FOR POWER AND ENERGY (FOR A CORE AND SHELL SPACE).  INSTALLING MINIMUM LIGHTING AND EXIT SIGNS REQUIRED PER BUILDING CODE.SCOPE INCLUDES NEW  PANEL RATED AT 600A CIRCUITS EQUIPMENT AND LIGHTS TOTAL AFFECTED AREA 10721 SQ.FT.B# 17016-10000-33840	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55772	18041-10001-21018	1844 W CYPRESS AVE	90065	1	148-5A215 107	5442004011	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	ADDRESS	34.10065	-118.23482	expedited feesPV2, ROOF MOUNTED SOLAR SYSTEM TO A COMMERCIAL BUILDING. (91) MODULES AND (2)INVERTERS, 10KW AND 15KW. TOTAL SYSTEM SIZE IS 35KWAC AND 27.7KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55773	15041-20001-23251	5548 N IRONDALE AVE	91367	3	174B109   509	2151033084	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.17153	-118.58527	Expedite fees.  Addition of solar modules and inverter to existing roof mounted PV array.  Addition size = 3 kWac.  Total system size = 9 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55774	17041-10000-07860	6719 S LA TIJERA BLVD	90045	11	102B173   831	4102001028	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	33.9779	-118.37141	Title 24 plan check.  Change of use from bank to restaraunt.  Three new subpanels with new lighting, kitchen equipment, and HVAC loads.  Total area = 2,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55775	10041-10000-20638	11641 W MORRISON ST	91601	2	168B169    39	2354009030	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2010 12:00:00 AM			PC Approved	12/15/2010 12:00:00 AM	ADDRESS	34.16049	-118.38687	Install a new 4.3KW PV system on the roof os a Single Family House.  Plan check was requested by the Inspector.Permit was issued under PCIS # 10041-10000-17079.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55776	17041-10000-36811	320 N MADISON AVE	90004	13	138B197   191	5501002032	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Apartment			11/29/2017 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.07708	-118.28902	PLAN CHECK FOR POWER AND ENERGY FOR NEW 6-STORIES MIXED USE BUILDING WITH 122 AFFORDABLE APARTMENT UNITS. TOTAL LIGHTING AREA 23118 SQ FT.Building application number: 17010-10000-01411	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55777	18041-10000-14532	1100 S SANTEE ST	90015	14	126A209   297	5145022001	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.03755	-118.25617	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55778	18041-30000-15382	2720 S LA CIENEGA BLVD	90034	10	123B173   637	5065012003	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	34.03352	-118.37567	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a second story addition/tenant improvement. Total lighting area = 4,175 sq. ft.Note: Building application has been generated under 16014-30000-05522. Electrical permit fees have paid under 18041-30000-12982.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55779	19041-20001-02741	11970 N SALEM DR	91344	12	216B133   351	2606021022	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.28796	-118.50785	Expedite per applicant request Plan check for PV roof mounted system, system size: 13.12KW with 41 PV Modules and 1 inverter(11.4KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55780	11041-10000-14595	5133 N LOUISE AVE	91316	5	171B133   396	2257014012	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.16442	-118.51002	NEW PV SYSTEM FOR SINGLE FAMILY RESIDENCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55781	18041-10000-30614	7640 N TOBIAS AVE	91405	6	186B149    42	2210031016	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.20973	-118.45183	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55782	18041-20000-29986	1141 N MANSFIELD AVE	90038	4	144B181   360	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.09202	-118.34057	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,720 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55783	17041-20001-18547	3258 S EDITH ST	90064	5	123B161   708	4316020005	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	34.03254	-118.40652	expeditepv1install roof mounted pv system sized 11.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55784	19041-20000-19393	3911 W EFFIE ST pv1	90029	13	145-5A203 138	5429012036	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.09396	-118.27851	pv1install roof mounted pv system sized 3.8KW AC interconnetced with msp.  (1) LG battery 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55785	14041-20000-31481	12780 N SAN FERNANDO ROAD PLANT 1	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Info Complete	11/13/2014 12:00:00 AM	ADDRESS	34.30237	-118.46212	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTS TO EXISTING PANELS.  2382 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55786	12041-10000-24103	5941 S WESTERN AVE	90047	8	105B193    94	6001014002	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	33.9867	-118.30911	SERVICE UPGRADE IN AN EXISTING BUILDING.  PLAN CHECK FOR POWER & ENERGY. TWO BUILDINGS IN ONE LOT.   (2 OF 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55787	19041-20000-02412	8537 N LOUISE AVE	91325	12	192B133    58	2787025003	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	04/15/2021 12:00:00 AM	ADDRESS	34.22589	-118.51	NEW PV1 ROOFTOP SOLAR SYSTEM CONSIST OF 49 MODULES, 49 OPTIMIZER, 1 LOAD CENTER, AND 2 CENTRAL INVERTERS. SYSTEM SIZE IS 16.41 kWdc and 13.95 kWac.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55788	14041-20000-28727	4568 N NAGLE AVE	91423	4	168B157   838	2360020036	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.15367	-118.42352	PV1.  Install 7.28 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55789	15041-20000-41528	11553 N BABBITT AVE	91344	12	213B133   470	2607007035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.28092	-118.50834	PV1.  Install 3.99 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.  (14) SolarWorld SW285 Mono panels w/ SB-5000TL transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55790	10041-10000-00489	1423 W PICO BLVD	90015	1	127-5A203 147	5137031014	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	02/18/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	34.04381	-118.27473	T24 lighting plan check only for change of use from retail space to restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55791	18041-20000-46936	4580 W ELECTRONICS PL	90039	13	162B201    16	5593012037	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.14436	-118.27496	Plan check for power only, replacement for circuit breakers and power equipment to existing distribution board. Indicated subpanels fitted with retrofit kits. No new load added, existing load to remain, all feeders to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55792	15041-10000-26358	335 W 31ST ST STE C	90007	9	120A203   127	5122018021	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.0231	-118.27594	PC FOR T-24. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55793	16041-20000-17305	9002 N DEBRA AVE	91343	12	195B137   143	2688033018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.234	-118.49044	PV1INSTALL ROOF MOUNTED PV SYSTEM STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55794	13041-10002-06157	3000 S HOOVER ST	90007	9	121-5A201 144	5123005031	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.02712	-118.28376	Changes to a approved set include change of 3 pole panel to 2 pole panel and a disconnect added for a ice mechine. page replace with the previously approved set.{{{8/12/14 changes to approved set. changing panel rr from 3phase to 1phase. relocation of receptacle in restroom building. plan check only. revisions to approved set of plansMinor changes to approved set of plansPLAN CHECK FOR POWER AND ENERGY FOR A NEW FIRE STATION #15. NEW 1000A SERVICE. INDOOR SQRFT: 15944 OUTDOOR SQRFT: 26617.}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55795	11041-10000-04831	3600 W WILSHIRE BLVD roof  of-21st floor	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM			PC Info Complete	03/15/2011 12:00:00 AM	ADDRESS	34.06156	-118.30335	The scope of work is to replace an existing 125 KW emergency generator with a new 150KW emergency generator in the same location, and a new 3 wire 4/0 AWG feeder to an existing 400 ampere 3 pole ATS.  No change in load or conditions of load useage indicated by the engineer.  Inspector please verify the rating of the circuit breaker  protecting the 350 MCM copper normal feeder to the ATS which does not comply with 240.4(B) as shown on the single line.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55796	13041-10000-06129	18970 W OXNARD ST	91356	3	177B121   582	2156014037	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.1801	-118.54689	PV1 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 5.88KW. 24 MODULES 1 INVERTER. TRANSFORMERLESS. [INVERTER: SOLAR EDGE SE6000A-US] [SOLAR MODULE: TRINASOLAR TSM-245 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55797	13041-20000-26143	2805 W LAWNDALE DR	90065	14	160-5A219 133	5683041003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.1345	-118.22605	pv1 single family dwelling. 3 inverters. less than 10k combined. total system size 7.8 kw AC using 26 modules. transformerless inverter nonstandard plan. 2 strings inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55798	19041-10000-11922	5855 W CENTURY BLVD	90045	11	090B169    11	4125025039	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	33.94572	-118.38488	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INLCUDES HOTEL ALTERATIONSBALLROOMS, MEETING ROOMS, AND BALLROOM RESTROOMS RENOVATIONREPLACING FINISHES, WALL SCONCES, DOWN LIGHTS AND DECORATIVE LIGHT FIXTURES. TOTAL SQ. FT. 59000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55799	15041-20000-19191	21501 W VENTURA BLVD	91367	3	171B105     7	2168027031	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	PIN	34.16881252	-118.59888323	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 10,210 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55800	11041-10000-18970	7046 N DARBY AVE	91335	3	183B125   420	2125004025	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	09/07/2011 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.19882	-118.53336	TI IN AN EXISTING OFFICE RAEA ON THE 1ST FLOOR.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55801	17041-10000-40437	16951 W AVENIDA DE SANTA YNEZ	90272	11	138B117   237	4431004050	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.07338	-118.5609	PC FOR ENERGY STORAGE, POWER WALL 2.BATTERY RATED AT 5.8KWac (13.5KWh)SCOPE INCLUDES ADDITIONAL NEW LOAD CENTER (200AMP)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55802	14041-20000-09839	6171 N PAT AVE	91367	3	177B085   134	2032010011	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.18328	-118.65888	PV1.  Install 7.5 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55803	16041-10000-25176	822 N SARBONNE ROAD	90077	5	141B149    78	4370002026	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.08479	-118.44904	ADDITION TO EXISTING SFD. ALL ELECTRICAL WILL BE NEW. NEW 800A SERVICE. INSTALLATINO OF STANDBY 60W GENERATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55804	14041-20000-21837	12746 W JEFFERSON BLVD SUITE 3140	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Issued	10/16/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR POWER ONLY. ENERGY TO BE CHECKED FOR NEW POWER DISTRIBUTION. NO LIGHTING UNDER THIS SCOPE OF WORK. PLAN CHECK FOR 2013 BUILDING EFFICIENCY STANDARDS FOR POWER. NEW TRANSFORMER AND PANEL FOR FUTURE TENANT SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55805	17041-20000-22306	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/03/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55806	19041-20000-46083	1611 S VICTORIA AVE	90019	10	126B185   150	5071004002	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Issued	11/08/2019 12:00:00 AM	ADDRESS	34.04469	-118.32996	Plan check for PV roof mounted system, PV system size: 4.32 KW with 12 PV Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55807	17041-10001-07174	1422 W 223RD ST	90501	15	048B193   688	7347003007	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM			PC Approved	04/24/2017 12:00:00 AM	ADDRESS	33.82438	-118.30231	Addition of new modules to an existing PV system on a single family home roof top. Adding 9 new micro inverters rated at 250W for total addition of 2.25KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55808	17041-10000-18209	17322 W PARQUE VANOWEN WAY	91406	6	180B133   597	2229008040	(Q)RD3-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.19338	-118.51076	Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system.  Total system size = 13.407 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55809	11041-10000-20454	7911 N HASKELL AVE	91406	6	189B141   131	2206003018	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00, 1274.00	Electrical	Electrical	Public Safety Only			09/26/2011 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	ADDRESS	34.21408	-118.47511	new fire warning/full evacuation ssytem for single store office building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55810	13041-10001-21996	4081 W 8TH ST	90005	4	132B189   531	5092011025	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.05822	-118.3171	"][]$0 FEE, DUE TO 2012 SENATE BILL 12222. CHANGES MADE TO APPROVED SET OF PLANS; CHANGES IS TO ACCOUNT FOR DOWNSIZING MAIN FROM 200A TO 125A BUS, CONDUIT SIZE FROM 1"" TO 3/4"". ORIGINAL DESCRIPTION:PV1 ROOF-MOUNTED INSTALLATION . SYSTEM SIZED AT 5.25 KW. (21) MODULES : HANWHA HSL 60 250W(21) MICROINVERTER: M215-60-2LL-S22"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55811	14041-10001-12380	100 WORLD WAY TERMINAL 1	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	33.94572	-118.40095	(((12/18/2014- REMOVING GENERATOR FROM THIS PHASE. WILL BE SHOWN ON THE PLANS UNDER THE FOLLOWING APPLICATION#: 14041-10000-27847. PLAN CHECK ONLY APPLICATION)))LAX TERMINAL 1 2 NEW SWITCHBOARDS SERVED VIA NEW 5000A BUSWAY. ALL DISTRIBUTION EQUIPMENT IS NEW. **NOTE, FUTURE LOADS ON EACH SERVICE SHALL NOT EXCEED 2500 AMPS AFTER LOAD SHEDDING**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55812	18041-10000-41262	3938 S BURNSIDE AVE	90008	10	117B177   310	5029028008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.01603	-118.36504	PV1. NEW UTILITY OWNED PV SYSTEM. TOTAL SYSTEM SIZE IS 3.6 KWdc/3.36 KWac. PV SYSTEM IS CONNECTING TO THE POINT OF INTERCONNECTION OF A SINGLE FAMILY  HOME. (12) MODULES-SOLARWORLD SW 300 AND  (12)MICROINVERTERS-ENPHASE S280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55813	12041-10001-30782	12751 W MILLENNIUM A	90094	11	102B161  1235	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/22/2014 12:00:00 AM			PC Info Complete	01/22/2014 12:00:00 AM	ADDRESS	33.9761	-118.41651	REVISION TO APPROVED PLANS. DELTA 27 AND 28 - ADD NEW CENTRAL WATER HEATING, CIRCULATING PUMP FOR BUILDING AND REMOVE GAS WATER HEATER FOR DWELLING UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55814	14041-20000-35320	141 N NEW HAMPSHIRE AVE 1-10	90004	13	138B197   718	5518027018	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			12/23/2014 12:00:00 AM			PC Info Complete	12/02/2015 12:00:00 AM	ADDRESS	34.07392	-118.29321	PLANCHECK FOR POWER AND ENERGY.  NEW 10 UNIT 4 STORY APARTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55815	14041-20000-08820	1837 N LA BREA AVE	90046	4	150B181   608	5572031004	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	Apartment			04/03/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Issued	05/02/2014 12:00:00 AM	ADDRESS	34.10441	-118.34619	Service upgrade from 400A to 600A for 3-story 15-unit apartment building.  Replacement of existing main and metered switchboard sections.Submittal fees altered to meet applicant's check amount.  4 vertical switchboard sections to be changed to 201-600A from 0-200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55816	15041-10001-08056	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.2426	-118.55846	Delta 2 changes only.TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING, INSTALLING NEW LIGHTING NEW CONTTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1131	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55817	16041-10000-16622	1502 W ROCKWOOD ST	90026	13	135A209   348	5159014010	(T)(Q)RAS4-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM			PC Info Complete	04/25/2017 12:00:00 AM	ADDRESS	34.06288	-118.26002	NEW 40 UNITS 4 STORIED TENANT BUILDING WITH NEW ELECTRICAL SERVICE (1600A) UNDERGROUND SERVICE.17 TYPICAL PANELS/UNITS.  34000SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55818	16041-10000-37446	21255 W CALIFA ST	91367	3	177B105    99	2149002009	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Issued	11/09/2016 12:00:00 AM	ADDRESS	34.17715	-118.59393	PC for power for replacing AC units. water heater and VAV boxes within office space. Total load being replaced exceeds 400A. Re-using existing feeder wiring for AC unit installation previously used for supplying pre-existing AC units reducing total load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55819	15041-10000-31437	12740 W MILLENNIUM lot 32	90094	11	102B161  1241	4211037012	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	33.97581	-118.4163	T-24 per 2008 energy code for hardscape. Total area: 18000 sq.ft***Scope: Park B, tract#60110-01-REC, Lot 32; 60110-REC, Lot3****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55820	11041-10000-08697	701 S HILL ST	90014	14	129A209   229	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM			PC Info Complete	06/22/2011 12:00:00 AM	ADDRESS	34.04582	-118.25475	T.I.  EXISTING HIGH RISE BUILDING.  ADDING NEW PANELS FOR FUTURE TENANTS.  FULL PLAN CHECK.  NO NEW LOAD ADDED. APPLICANT IS REQUESTING EPC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55821	15041-20000-03875	930 S HILGARD AVE	90024	5	135B153   601	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.06306	-118.44116	PC FOR POWER AND ENERGY. PLACE OF ASSEMBLY. T.I. TO EXISTING RESTAURANT. NEW LIGHITNG AND EQUIPMENT. NEW DIMMING PANELS. PART OF A HIGHRISE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55822	14041-20001-00776	3809 N ROCK HAMPTON DR	91356	3	162B125   241	2184057010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.14001	-118.53382	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS FOR 1 INVERTER. TOTAL SYSTEM SIZE 6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55823	15041-10000-36600	5616 E ASH ST	90042	1	153A227   317	5469032007	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	01/16/2016 12:00:00 AM	ADDRESS	34.11248	-118.19593	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.16KWac.(24)MODULES-HYUNDAI HIS-M255MG(24)MICROINVERTERS-ENPHASE m215-60-2LL-S23	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55824	19041-10000-21274	2727 W DICTURN ST	90065	14	157-5A219 137	5473018020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.12649	-118.22575	New PV1 rooftop 7.6 kW AC system/ 6.57 AC CEC. Installation of (23) modules, (23) P320, (1) 7.6 kW SE inverter. System connect to (E) 200A MSP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55825	13041-10000-04477	5410 N GENTRY AVE	91607	2	171B165    56	2348011007	[Q]RD2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.16908	-118.39308	PV1 for one story, single family dwelling. Total system size 4.32KW. Transformerless system. [Microinverter: SolarEdge Single Phase Inverters. Model#: SE3800A-US] [Solar Module: Trinamount II. Model#: TSM-240-PC/PA05.18] [Power Optimizer: Solar Edge Power Optimizer. Model#: OP250-LV]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55826	18041-20000-28133	2857 W 7TH ST	90005	1	133-5A201 145	5077014026	C2-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.05994	-118.28577	Plan check for a PV2 roof-mounted PV system. System size is 9.24 kWdc and consists of (1) 10 kWac rated inverter and (28) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55827	13041-10001-10816	6245 W 87TH ST	90045	11	096B165   717	4123003026	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM			PC Approved	12/20/2016 12:00:00 AM	ADDRESS	33.95867	-118.39444	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 2. REVISED LIGHTING LAYOUT AND UPDATED KITCHEN EQUIPMENT CIRCUITRY. THIS IS PLAN CHECK ONLY. NO ADDITIONAL PERMIT ITEMS NEEDED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55828	13041-10000-11513	12114 W IDAHO AVE 1-11	90025	11	126B145   985	4259004043	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			05/03/2013 12:00:00 AM	05/03/2013 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.03841	-118.46159	New fire alarm system in 4-story apartment building.  1 new fire alarm panel, 35 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55829	16041-20000-24633	10730 N MEMORY PARK AVE UNIT C	91345	7	207B145   239	2649003028	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.26537	-118.46322	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED TO MSP FOR UNIT C.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55830	19041-20001-28109	19864 W FALCON CREST WAY	91326	12	217-5A115 120	2701025015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM			PC Approved	08/19/2019 12:00:00 AM	ADDRESS	34.28944	-118.5668	Expedited plan check fee.PV1.  Install 6.48 kW roof mounted grid tied PV system.  10 kWh energy storage system.  Protected load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55831	19041-10000-02851	8340 N VAN NUYS BLVD STE B	91402	6	192B149   292	2638022061	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.22301	-118.44856	TENANT IMPROVEMENT IN A ROSS RETAIL STORE; PLAN CHECK IS FOR POWER AND LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55832	16041-10004-24464	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			PC Info Complete	05/07/2018 12:00:00 AM	ADDRESS	34.09818	-118.35187	Changes to an approved set of plans. All changes are clouded under delta 14 & delta 15. Changes include relocating/replacing lighting fixtures, updated lighting floor plans, revising title 24 calculations, revising emergency photometrics, revising panel schedules, and adding/removing circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55833	19041-10000-06119	3737 S MOTOR AVE	90034	5	120B165  1341	4314003037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			02/20/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	02/25/2022 12:00:00 AM	ADDRESS	34.02157	-118.40525	New 5-Story, 30 Units, Apartment with Commercial space over 1-level subterranean Parking Garage and 1 level at grade parking with 800 Amp Service. Building Permit: 17010-10000-04508	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55834	18041-10000-20842	1585 W CURRAN ST	90026	13	145-5A211 168	5443016015	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	06/30/2018 12:00:00 AM	ADDRESS	34.09359	-118.24784	Plan check for a PV1 2.8KW DC roof mounted system with (10) modules and microinverter interconnecting through a subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55835	11041-20002-13962	22100 W ERWIN ST	91367	3	177B101    79	2146003022	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Apartment			08/11/2011 12:00:00 AM			PC Approved	08/11/2011 12:00:00 AM	ADDRESS	34.18263	-118.60809	PLAN CHECK T24 ENERGY AND EMERGENCY LIGHTING REVISION TO APPROVED PLANS. EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55836	17041-10000-20718	2430 E PORTER ST	90021	14	121-5A217 295	5168029024	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.02651	-118.22916	PC FOR REPLACE LIGHTING FIXTURES TO LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55837	17041-20003-18438	22801 W ROSCOE BLVD Bldg. 2	91304	12	192B097   578	2005002011	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.22014	-118.62547	9/4/2018changes to an approved set of plans.  changes noted delta 10 only.  changes to include new transformer to limit fault level to existing back up chiller.  plan check for power only. (((06-01-2018 Changes to an approved set of plan. Changes include relocate load to panel 2HM. All changes has been clouded as delta 9.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55838	19041-10000-34121	1901 S WESTWOOD BLVD	90025	5	129B153   785	4323002024	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	34.04791	-118.43543	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55839	10041-20000-10809	15821 W VENTURA BLVD #270 & 280	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	06/08/2010 12:00:00 AM		Permit Finaled	07/30/2010 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check T-24 Energy general/emergency lighting for office TI on the 2nd floor (suite #270 &280).  New lighting circuits and existing branch circuits for receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55840	14041-10000-16088	3040 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.01637	-118.21457	Plan check for power only. Addition of (1) 1200A 480/277 3p4w 65kaic section with GFI to (E) SERVICE EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55841	10041-20000-23802	600 W WILSHIRE BLVD #1450-#1400	90017	9	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	ADDRESS	34.04796	-118.25622	T.I. to existing high rise building.  Relocate general/emergency light on 14th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55842	19041-10000-09937	2600 S HOOVER ST BLD. B, C,-D	90007	9	123A201   122	5123001900	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			03/20/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	11/15/2021 12:00:00 AM	ADDRESS	34.03132	-118.2838	[This set of plan covers plan check for both buildings] Full plan check for power and energy for alteration and minor addition and repair of existing SRO hotel building with 37 units total. Scope includes new 1600A service and all new equipment. Fully new electrical system. There are two building permits assigned to this property for two different building on the same lot with one electrical system serving both. Building B, C, D: B#18016-10000-31040: Conversion of existing historic 46 units into 27 units of low income housing and supportive services.  New elevator to be provided.Building A: B#18016-10000-31043: Conversion of existing historic 9 guestrooms into 10 unit of low income housing and supportive services.*See application comments	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55843	19041-10000-21628	6001 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	05/05/2020 12:00:00 AM	ADDRESS	34.06297	-118.35952	PC for T24 only, scope work is a new storage space, provide new lighting, recpactles, and equipment. Total affected area is 932 sqft.IN LOADING DOCK AREA. BLDG Scope((FOR NEW STORAGE BUILDING COMPRISED OF LIGHT GAUGE METAL CONSTRUCTION, INTERIOR LIGHT FIXTURES, POWER RECEPTACLES AND EXHAUST FANS))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55844	11041-20000-24255	5112-5118 W JEFFERSON BLVD	90016	10	120B177   742	5047001003	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	34.02537	-118.35568	PLAN CHECK T24 ENERGY FOR EXISTING COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55845	16041-30000-06713	11200 N CORBIN AVE Suite 200	91326	12	210B117   384	2701040027	(Q)C1.5-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.27517	-118.5618	Title 24 plan check only.  Total area = 4,294 sq. ft.     T.I. to existing two story office building.  Two new subpanels + new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55846	18041-20000-17697	11601 W WILSHIRE BLVD 4th Floor-Rest Rooms	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing space T.I. restroom. Total area: 533 sq ft.B#18016-10000-13112	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55847	17041-10000-25415	234 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.05578	-118.25359	PC for T24 only for new hallway lighting and facade lighting. Total affected area 18858 sqft. Building # 16016-10000-01392	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55848	12041-10000-21099	5570 S LINCOLN BLVD	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	33.97271	-118.43031	TI IN AN EXISTING COMMERCIAL BUILDING. CHANGE OF USE TO A NEW LA FITNESS CENTER ON FIRST FLOOR OF 2 STORY BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55849	16041-20000-11169	800 S FIGUEROA ST Ste 1000	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	TI for an (E) commercial office space in an (E) commercial highrise building.  Plan check for energy.  2,186 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55850	17041-10000-17806	2708 E CESAR E CHAVEZ AVE 101-302	90033	14	127-5A225  74	5180017002	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.04477	-118.2039	PC per inspector request for energy only, Indoor Title 24. TI on Banquet hall (2nd floor and 3rd floor hallway ) under 2008 energy code. Permit under original #15041-10000-36772.Total affected area is 4,568 Sq. Ft.Plan check only!Building  permit  done under previously expired permit #10016-10000-20904 (building application has been extended under 17016-10000-13576). Total affected area is 4,568 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55851	16041-30000-38091	9180 N KELVIN AVE	91311	12	198B109   125	2748036008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.23794	-118.58525	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55852	16041-10002-37492	200 WORLD WAY T2 LEVEL 4	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA DCN-029 ON PLANS. UPDATED LIGHTING SCHEDULE, T24 AND PANEL SCHEDULE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55853	15041-20000-00761	4912 N MORSE AVE	91423	4	168B161   186	2358023007	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Expired	02/06/2017 12:00:00 AM	ADDRESS	34.15988	-118.41583	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING STANDARD PLAN. TOTAL OF 30 MODULES.Note: solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55854	17041-10000-30995	23506 W DOLOROSA ST	91367	3	174B093   486	2044007016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.1699	-118.63865	PC for new 11.4kW rooftop solar. Installing 44 PV panels and one solaredge SE11400A central inverter.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55855	14041-10000-34636	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	PC FOR ENERGY , TITLE 24, AND POWER. TOTAL AREA 1161 SQ FT. FIRST TIME TENANT. PART OF HIGH RISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55856	15041-20000-18877	11315 N GOTHIC AVE	91344	12	210B137    19	2681013029	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.27619	-118.48923	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 125A MSP w/100A main disco.System size: 7.6kW. Ungrounded system. Using 400W power optimizers on each of the (32) 315W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55857	17041-20002-24776	8500 N BALBOA BLVD SUITE #170	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM			Verifications in Progress	02/26/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	01.29.2018 - Plan check for changes to approved set.  Approval for clouded changes only.  Grounding detail changes, revisions to SLD, and luminaire schedule/aluminum feeder schedule revisions.  (((12.7.2017 - Plan check for changes to approved set. Update feeders >100A from copper to aluminum. Update fault current study (sheet  E-921) to show aluminum feeders. Add aluminum fixture schedule (sheet E-901). Changes clouded delta 13. Note: changes to lighting fixture schedule ignored for this plan check. ======Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area of 96,648 sq. ft.Note: Building application has been generated under 17016-10000-15426)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55858	18041-20000-18391	1260 N PIEDRA MORADA DR	90272	11	135B121     6	4431033003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	09/15/2018 12:00:00 AM	ADDRESS	34.07002	-118.55144	PV1.  Install 13.58 kW DC/12.44 kW AC roof mounted grid tied PV system.  (41) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55859	16041-10001-01606	1734 S BAGLEY AVE	90035	5	129B169   904	4305025015	R1-1	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.04877	-118.39059	7/11/16: Revision to approved plan:1. Change inverter from PVI-6000-OUTD to SE7600A-US2. Additional (1) module, total now (33) modules.3. System is using Power Optomizer (Permit is issued under the Master PCIS#)<<INSTALL 8.48 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(32) MODULES: KYOCERA KU2656ZPA(1) INVERTER:  ABB PVI-6000-OUTD-US-Z-A* standard plan is being used>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55860	19041-20000-18972	16501 W ALYSE CT	91436	5	168B137   808	2284005037	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	07/08/2019 12:00:00 AM	PIN	34.1561989	-118.49263244	(4) tesla powerwalls ESS.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55861	14041-20000-02843	13460 W POLK ST	91342	7	231B157   142	2582031054	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.32823	-118.4296	pv1 single family dwelling. total system size 5kw ac using transformerless inverter nonstandard plan using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55862	14041-20000-03831	9117 S HOOVER ST	90044	8	094-5A199 120	6039002061	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	33.95374	-118.28711	pv1 single family dwelling. total system size 3kw AC using transformerless inverters nonstandard plan. using power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55863	19041-20000-35090	8637 W OLIN ST 1-3	90034	10	123B169   504	5065009008	[Q]R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Apartment			09/05/2019 12:00:00 AM			Corrections Issued	09/05/2019 12:00:00 AM	ADDRESS	34.03467	-118.38126	NEW 3-UNIT APARTMENT BUILDING WITH 400 AMP 120/240 SINGLE PHASE. PLAN CHECK FOR POWER FIRST TIME TENANT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55864	19041-10000-49954	12061 W LUCILE ST	90230	11	105B161   556	4220013023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.98457	-118.40897	[EPLAN]] CHANGES ON APPROVED SET. MODULE LAYOUT HAS CHANGED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55865	17041-10000-31469	2029 S CENTURY PARK EAST 1280	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for T24 only, TI  on the interior of (E) office space Ste.# 1280. Panels are existing, just add few circuitry with new load < 200A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55866	11041-10000-03294	1888 S CENTURY PARK EAST 2ND FLOOR	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/18/2011 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	04/01/2011 12:00:00 AM	ADDRESS	34.06104	-118.41402	TI IN THE RESTROOM ON THE 2ND FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS AND THE EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55867	12041-20000-23640	5757 W CENTURY BLVD GF 102	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	33.9457	-118.38274	Plan check for energy and emergency building. High rise building. Ground Floor. 8840 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55868	18041-10000-07321	9151 W PICO BLVD	90035	5	132B169   750	4332002049	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.05542	-118.39094	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK INCLUDES A  NEW MICROTURBINE C1000, ELECTRICAL RATINGS: 480V,3PH, 990KW, NEW MOTORA LOADS, AND STEP DOWN TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55869	14041-20000-05722	15724 W COVELLO ST	91406	6	186B141   179	2206014023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Expired	04/11/2016 12:00:00 AM	ADDRESS	34.20742	-118.47589	Roof mounted PV system 4KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55870	15041-20000-42783	16470 W OLDHAM ST	91436	5	162B137    82	2293004002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.14306	-118.49189	"""0$ permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:14.28 KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55871	15041-20000-08808	13793 N WHEELER AVE	91342	7	228B153   261	2503002040	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.32248	-118.44104	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system.  Main circuit breaker to be derated to 150 A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55872	14041-10000-18002	8018 N CANTALOUPE AVE	91402	6	189B153   366	2213013022	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.21672	-118.43362	Install roof-mounted solar array, interconnect with main panel. System size 11.43kW. Two solar edge converter. One 6000 one 5000. Ungrounded system. Expedited	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55873	17041-10000-33578	7565 N LOCKHEED DR	91505	2	186B177   568	2466036008	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.20774	-118.35396	PLAN CHECK FOR POWER AND ENERGY FOR A (T.I. REMODEL 1ST FL & MEZZANINE, NON-BEARING INTERIOR PARTIONS ; NO CHANGE OF USE). PLAN CHECK INCLUDES EXISTING 480/277-400A SERVICE WITH TOTAL CONNECTED LOAD > 400A, WITH A TOTAL AFFECTED AREA = 24179 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55874	15041-20000-24284	2159 E SACRAMENTO ST	90021	14	123A217   222	5166005008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.0307	-118.22801	Plan check Title 24 only for T.I.  in existing office space and industrial. Total indoor lighting area: 10,343 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55875	15041-10000-22124	828 W 108TH ST	90044	8	088-5A199  60	6061007008	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	33.93807	-118.29048	PV1, ROOF MOUNTED SYSTEM, 27 MODULES AND 1-6KW INVERTER. TOTAL SIZE 7.155 KW(27) KYOCERA #KU2656ZPA(1) PV1-6000-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55876	15041-10000-03400	17401 W VENTURA BLVD Space B13	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.16136	-118.51189	TI to new hair salon in existing commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55877	19041-10000-04485	3030 W OLYMPIC BLVD SUITE #113	90006	10	129B193   316	5080033029	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.0524	-118.3013	TI IN AN EXISTING COMMERCIAL AREA IN SUITE #113. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-01343	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55878	17041-20000-25745	15206 W PARTHENIA ST	91343	6	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.2281	-118.46381	0$ permit fees due to senate bill 1222pv2install roof mounted pv system sized 55kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55879	17041-10000-41771	9068 N DE GARMO AVE	91352	6	195B173    59	2408033009	M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.23385	-118.37328	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55880	13041-10000-27831	11150 W SANTA MONICA BLVD STE 900	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.04704	-118.44563	TITLE-24 ONLY; TI FOR EXISTING COMMERCIAL(OFFICES) HIGH-RISE BUILDING. EMERGENCY LIGHTING IS NOT IN SCOPE OF WORK PER ENGINEER. REPLACING INCANDESCENT LIGHTS FOR CFL AND RELOCATING PENDANT LIGHTS AND WALLWASHERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55881	16041-10000-06370	1649 1/2 W 59TH PL	90047	8	105B193   192	6002009018	R1-1	South Los Angeles	South Central Los Angeles	Empowerment Congress Central Area		2372.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Expired	03/26/2018 12:00:00 AM	ADDRESS	33.98682	-118.30628	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(8)MODULES-KYOCERA #KU2606XPA(1)INVERTER-ABB-3.0_OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55882	17041-10000-23614	3361 N ANDRITA ST LOT 7	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 7 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05789	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55883	10041-20002-16671	12740 W ARROYO ST	91342	7	219B161   249	2525027014	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM			PC Approved	12/09/2010 12:00:00 AM	ADDRESS	34.29585	-118.41002	PLAN CHECK ONLY. PLAN CHECK FOR DELTA 2.  REVISION TO CHANGE SCOPE OF INSTALLATION. REMOVE (2) AIR COMPRESSOR EQUIPMENT AND XFMRS FROM PREVIOUS APPROVED PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55884	10041-10000-23504	505 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Closed	05/17/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY  ( 2-DAYS ) STANDBY GENERATOR  TO SUPPLY POWER TO EACH OF TWO MCC WHICH POWERS EXISTING LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55885	14041-20001-10123	22412 W SENTAR ROAD	91364	3	168B101   332	2076006031	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.15813	-118.61526	EXPEDITED BY CUSTOMER REQUESTPV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.25KW INTERCONNECTED WITH MAIN PANEL  TRANSFORMERLESS AURORA PVI-3.6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55886	14041-20000-16018	6541 N HAYVENHURST AVE	91406	6	180B137   357	2231008033	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.18986	-118.4926	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55887	14041-10000-22980	8256 N LAUREL GROVE AVE	91605	2	192B165   521	2309011027	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Expired	09/22/2016 12:00:00 AM	PIN	34.22128715	-118.40056431	Installation on the roof of SFD 7.395 KW PV system	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55888	19041-10000-07345	21045 W OSBORNE ST	91304	3	195B105    41	2779048009	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.23322	-118.59228	TI IN AN EXISTING COMMERCIAL SPACE. INSTALL NEW LIGHTS.13,099 SQR FT. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-03172	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55889	16041-20000-41002	10255 ANGEL LANE	91331	7	204B165   437	2537004047	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25691842	-118.40478932	pv1install roof mounte pv system sized 3.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55890	14041-10000-24016	2080 CENTURY PARK EAST #707	90067	5	132B161    39	4319001014	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	PIN	34.05920818	-118.41153897	T24. TI for doctor's office in high rise. New lights and plugs. total area = 1675 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55891	17041-20001-31574	8800 N CHIMINEAS AVE	91325	12	195B125   688	2769016013	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	09/11/2017 12:00:00 AM	ADDRESS	34.23023	-118.52829	Expedited plan check fee. PV1.  Install 4.13 kW roof mounted grid tied PV system.  (14) modules with 3.0 kW rated central inverter.   13.5 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55892	10041-20000-00253	21727 W NORDHOFF ST Bldg. A	91311	12	198B105   182	2746012001	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM	01/19/2010 12:00:00 AM		Permit Finaled	03/01/2010 12:00:00 AM	ADDRESS	34.23562	-118.60323	Tenant improvement in Building A, office/wholesale space. Title 24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55893	16041-10000-45478	330 E 90TH ST	90003	9	094-5A205  71	6041027028	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	33.95454	-118.26842	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(17)MODULES-HANWHA Q-CELL Q PLUS(1)INVERTER-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55894	17041-10000-09844	1126 W 11TH ST	90731	15	015B193   914	7458010026	RD2-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	33.7345	-118.30187	PC FOR ROOF TOP PV SYSTEM TOTAL OF 26 MODULES AND 6.6KW CENTRAL INVERTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55895	13041-10000-06434	15864 W SHERMAN WAY	91406	6	183B141   137	2224003073	[T][Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.20098	-118.47924	ON THE 1ST, 3RD AND FIFTH FLOORS OF AN OFFICE BUILDING, REPLACING LUMINAIRES -ONE FOR ONE-. EMERGENCY LUMINAIRES AND LIGHTING CONTROLS REMAIN THE SAMEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55896	15041-10000-30970	11455 W BURBANK BLVD Bldg C	91601	2	174B169   780	2338027***	R4-2, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.17232	-118.38083	TI to an exisiting religious assembly site (2-story building), Church of Scientology-Area C. New 600 Amp service, all equipment is new. Full Plan Check. Total Sq ft = 29,141.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55897	14041-10001-15893	5213 E MONTE VISTA ST STE#B	90042	1	151-5A227 248	5469019024	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.10885	-118.2008	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55898	16041-30001-44903	107 N DELFERN DR	90077	5	141B157   130	4358005006	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.08012	-118.42866	01/08/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Optional standby generator and additional panels have been added and loads have been relocated to accomodate new configuration.*****Original Work Description*****Plan check for power only. Upgrade service to 1200A for (E) SFD and (N) Guest House. Guest house wiring and distribution are all new. Reconnect existing SFD distribution/wiring to new service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55899	18041-10000-46170	3046 S FARMDALE AVE	90016	10	120B181   651	5057022026	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Issued	12/05/2018 12:00:00 AM	ADDRESS	34.02624	-118.3459	New 3.465 KW Roof mounted PV system with 11 PV panels on a single family house.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55900	17041-10000-20427	16200 W VENTURA BLVD	91436	5	168B137   450	2284003020	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Issued	06/19/2017 12:00:00 AM	ADDRESS	34.15647	-118.48571	T-24 for outdoor lighting only. Lighting to be installed under the benches as decorative lighting. Total sq. ft. 465.     Building permit #16016-10000-23812	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55901	15041-10000-14079	1140 S GAYLEY AVE	90024	5	132B149   112	4363023030	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM			PC Info Complete	06/16/2015 12:00:00 AM	ADDRESS	34.05955	-118.44565	Plan check for power and energy for a new restaurant, first time tenant, located at  mix-use building. Scope includes installation of  4-new panels, equipment, lighting and receptacles..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55902	14041-20000-18407	14920 W PARTHENIA ST	91402	6	195B149   610	2653010018	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	Apartment			07/08/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	34.228	-118.45803	EXTESION GRANTED ON 7-8-2014 TO EXTEND UNTIL JANUARY 7-2015.  THE JOB COSIST OF NEW 39 UNITS APARTMENT BUILDING IN ADDITION TO RENAVATION TO EXISTING 88 UNITS.  THE RENOVATION CONSIST OF FEEDER TO PANELS ONLY.  ADDITINAL PLAN CHECK HOUR WAS CHARGED TO COVER THE FEEDER TO EXISTING PANELS AND CHANGE OF SERVICE LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55903	16041-10001-45795	9301 N TAMPA AVE SUITE #177	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	04-06-2017 Changes to an approved set of plans. Changes include revised lighting fixtures and update panels schedule. Changes has been clouded as delta 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55904	17041-10000-34986	3420 N PORTOLA AVE	90032	14	142-5A235 118	5219010001	[Q]RD5-1D	East Los Angeles	Northeast Los Angeles	LA-32	Yes	2015.03	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.08552	-118.17248	REPLACE HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55905	17041-10000-43371	811 W 7TH ST 2nd Flr	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.04908	-118.25911	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS FOR EXISTING MENS'S AND WOMEN'S RESTROOMS ON SECOND FLOOR. TOTAL AFFECTED AREA IS 147 SQ. FT. B#16016-10000-16932	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55906	11041-10000-18013	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI TO AN EXISTING OFFICE SPACE.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55907	19041-10000-36887	5784 W MELROSE AVE	90038	4	141B189   392	5523010020	C2-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM			Reviewed by Supervisor	11/13/2019 12:00:00 AM	ADDRESS	34.08327	-118.32615	FULL PC FOR 7-ELEVEN RETAIL. EXITING SERVICE IS 2000A, 208V, 3PH, 4W. SCOPE OF WORK AREA 2039SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55908	12041-10000-30008	380 W WORLD WAY level 3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Recalculate fees since applicant brought check.FULL POWER AND ENERGY. LAX. storage for the DUTY-FREE shops (Unit # 3s2-07C-G). 1ST TIME TENANT.  Located on level 3 back of the house. Methane. Separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55909	17041-10001-24311	1180 S BEVERLY DR	90035	5	132A167   184	4330031026		West Los Angeles				2691.00	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.05581	-118.39554	PC FOR CHANGES TO AN APPROVED SET UNDER DELTA 8. SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55910	17041-10000-44014	2826 E 1ST ST	90033	14	126A225    44	5180014003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.04097	-118.20394	CHANGE OF USE FROM WAREHOUSE TO RECORDING STUDIO, OFFICE, AND (TWO) LIVE-WORK UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55911	17041-20000-31073	5738 N OAKDALE AVE	91367	3	174B113   152	2153018019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.17554	-118.56553	PV1.  Install roof mounted PV system sized 12 kW interconnected with MSP.  $0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55912	12041-10001-22577	7270 W MANCHESTER AVE	90045	11	096B157   625	4119026042	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Apartment			03/26/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.95959	-118.42143	Supplemental Title 24 plan check for outdoor and facade lighting for a 6 floor apartment building.  Not a highrise as per applicant.  Total hardscape area 25,663 sq ft.  All changes indicated by Bulletin #5.(((NEW 6 STORY 260 UNITS APARTMENT BLDG WITH 3 LEVELS UNDERGROUND PARKING.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55913	11041-10000-11657	8500 W BEVERLY BLVD 778-A	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Finaled	08/30/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT OF AN (E) 1029 SF REMOTE STORAGE AND RECORDSplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55914	12041-10003-23829	236 S LOS ANGELES ST	90012	9	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			10/29/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Closed	03/18/2015 12:00:00 AM	ADDRESS	34.04922	-118.24386	Addition of retail distribution section (for future tenant move-in).  (((Construct 176-unit apartment with retail and basement garage. Variance is required to separate the FIRE ALARM plans...  ((((((((((((( VALUE ENGINEERING,    4000 AMPS FEEDER, TO AL.  ALL  METER SECTION TO 80 AMPS , ELEVATION. ETC)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55915	10041-10000-20071	4021 W ROSEWOOD AVE 1ST & 2ND	90004	13	141B197  1101	5520006012	(Q)CR-2	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.07919	-118.29256	ON THE 2ND AND 1ST FLOORS, REPLACING THE LUMINAIRES IN THE CORRIDORSPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55916	13041-10000-30473	1891 N ACADEMY DR	90026	1	141B213    20	5415005902	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.08305	-118.2417	NEW 2 STORY LAPD ACADEMY TRAINING FACILITY. PLAN CHECK IS FOR POWER AND ENERGY.NOTE: FIRE ALARM PLAN APPROVED UNDER 13041-10000-35522	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55917	11041-10000-25971	940 W HARRY BRIDGES BLVD	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	PIN	33.77046453	-118.27163726	LEVEL V METHANE  MITIGATION SYSTEM FOR NEW GUARD HOUSE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55918	17041-20001-35822	20406 W VIA MANTUA	91326	12	219B109   318	2701059026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.29947	-118.57867	EXPEDITED PER APPLICANTS REQUEST. (4) 14KW ENERGY STORAGE SYSTEM + PV1 ROOFMOUNTED PV SYSTEM. SYSTEM SIZE: 14.95 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55919	19041-10000-09637	13190 N TELFAIR AVE	91342	7	225B141   186	2604002039	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.31055	-118.47872	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR AND OUTDOOR)- T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55920	18041-10001-40691	11866 RICASOLI WAY	91326	12	216B109   122	2701078036	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	PIN	34.28856498	-118.58424273	SUPPLEMENTAL FOR CHANGES TO APPROVED SET. CHANGING WIRE SIZE AND ASSOCIATED CALCS (VD CALCS AND MIN WIRE SIZE CALCS) FOR J-BOX TO LOAD CENTER WIRE RUN.NOTE: PERMIT FEES ARE COVERED UNDER MASTER APP: 18041-10000-40691	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55921	16041-20000-38810	6303 N OWENSMOUTH AVE 6th Floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.18474	-118.60182	Plan check for energy only. TI to existing office (XLAB Suite) in high rise building. New lighting (incl. emergency) and receptacles. 1,802sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55922	19041-20000-17938	17343 W SIGNATURE DR	91344	12	216B129   279	2606026025	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.28725	-118.51262	pv1install roof mounted pv system sized 22.8KW AC interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55923	14041-10000-11124	10100 W SANTA MONICA BLVD SUITE 200	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55924	14041-10001-11993	8201-8203 W 3RD ST	90048	5	138B173   840	5511019036	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM			PC Approved	01/14/2015 12:00:00 AM	ADDRESS	34.07259	-118.36814	Plan check only. Change to approved set by changing the service  from overhead to underground in a methane zone with seal off is provided.  Note. all changes are applied to Delta-A only. (((Plan check for power and energy. Core and Shell only. Tenant to pull separate permit for TI.  TOTAL AREA INDOOR 1306 SQ FT. BLDG#14010-10-01124: PROPOSED NEW 1 STORY RESTAURANT W/ROOF DECK OUTDOOR DINING AREA - CORE & SHELL PERMIT (T.I. UNDER SEPARATE FUTURE PERMIT). SEE COMMENTS. TV = 220,000 (1 OF 2))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55925	19041-10000-45878	11330 W MCCORMICK ST	91601	2	171B173   479	2350017021	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.16579	-118.37851	PC FOR ENERGY ONLY T-24 FOR OUTDOOR LIGHTING. TOTAL AFFECTED AREAS IS 13025 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55926	16041-20000-38470	21610 W VENTURA BLVD	91364	3	171B105    54	2168023067	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			PC Approved	10/31/2016 12:00:00 AM	ADDRESS	34.168	-118.6002	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 653 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55927	11041-10000-11457	11311 W MISSISSIPPI AVE	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.03944	-118.443	TI TO AN EMPTY SHELL, FIRST TIME TENANT.  SINGLE STORY.  PLAN CHECK IS FOR ENERGY AND POWER.  NEW ICE CREAM SHOP.  ALL PANELS AND SERVICE ARE EXISTING, NEW CIRCUITS ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55928	12041-10000-20331	735 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Issued	12/06/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	TENANT IMPROVEMENTS FOR EXISTING SHELL ONLY RESTAURANT(2313 S.F.)  WITH REMOTE STORAGE /FOOD PREPARATION AREA (500 S.F.) AND ADD SEATING AREA (312 S.F.) AT INTERIOR OPEN PATIO IN EXISTING FOODCOURT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55929	14041-20000-17431	16501 W VENTURA BLVD SUITE 104,-110	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Issued	06/27/2014 12:00:00 AM	ADDRESS	34.1578	-118.49275	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY ONLY.  EXISTING HIGH RISE BUILDING. INSTALLING NEW LIGHTING FIXTURES ON EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55930	16041-10000-19526	149 E 75TH ST	90003	9	102B205  1330	6022003036	R1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	33.97224	-118.27217	PV1. NEW SOLAR SYSTEMON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS  2.65KWdc / 3.0 KWac(10) MODULES (KU-2656ZPA)(1)INVERTER-ABB INVERTER (PVI -3.0-OUTD-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55931	19041-10000-36140	15263 W FRIENDS ST	90272	11	123B125   169	4412026013	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.0357	-118.5268	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIVIA 3.8 TL) WITH 13 MODULES USING RAPID SHUTDOWN DEVICE AND 2 ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55932	14041-10001-08776	1935 E 7TH ST	90021	14	124-5A217 213	5164021009	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	10/17/2014 12:00:00 AM	ADDRESS	34.03477	-118.2329	(((EXPEDITE FEES)))PV2 ROOF MOUNTED 3PHASE SYSTEM. TOTAL SYSTEM SIZE 50KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55933	16041-10000-41685	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.20615	-118.41279	PC FOR REPLACEMENT OF FA SYSTEM LIKE NEW. PROVIDING NEW CONTROL PANEL AND REPLACE ALL DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55934	13041-10000-20573	919 S GRAND AVE	90015	14	127-5A209  97	5139007036	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.04413	-118.25988	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. CLASSROOM TENANT IMPROVEMENT. SCOPE OF WORK IS LESS THAN 400A.EMERGENCY LIGHTING IN CORRIDOR IS FED FROM EXISTING EMERGENCY CKT, VIA GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55935	13041-20000-35225	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	INTERIOR TENANT IMPROVEMENT OF 12,329 SF  OFFICE SPACE ON THE FIRST FLOOR FOR PORTION BLDG A AND ENTIRE BLDG B; (((work done in medical exam rooms and common areas. full plan check per aticle 517, NON OSHPD 3 required))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55936	18041-20001-17245	900 N NORTH BROADWAY # 1080	90012	1	135A215   238	5414013901	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.06408	-118.23726	[[[7/6/18 CHANGES TO APPROVED T24 ENGERY. PLANCHECK ONLY. CHANGING ROOM LAYOUT ]]]]Plan check for Title 24 only in existing spce T.I. retail space number: 1080. Total area: 1815 sq ft. B#18016-10000-09503	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55937	10041-10000-11981	542 S LOS ANGELES ST	90013	9	127-5A211  63	5148017005	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.04496	-118.24835	TI IN A RETAIL STORE. PLAN CHECK FOR T24. (Permit is allready issued #10041-10000-09092, Plan check per inspector request.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55938	12041-20000-09630	752 S MAIN ST 111-113	90014	14	127-5A211 211	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Info Complete	04/27/2012 12:00:00 AM	ADDRESS	34.04283	-118.2527	Plan check for energy and emergency lighting. 3286 conditioned sqft. 1st floor is commercial. Units 111 & 113 were checked. Plan check per customer's request. All lights, wiring were existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55939	19041-20000-51559	6629 N NEVADA AVE	91303	3	180B101   305	2139016009	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.1909	-118.60938	Plan check for PV roof mounted system, PV system size: 4.48KW with 14 PV Moduels and 1 inverter(3.8KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55940	13041-10000-29539	3115 N DONA MARTA DR	91604	2	156B173    46	2380023006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.12766	-118.37798	Permit to be pulled over the counter. PV1.  Install 9 kW DC Photovoltaic system interconnect with main service panel at the opposite end of main OCPD. Inverter: Fronius IG Plus V 7.5.  16 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55941	18041-10000-35678	15452 W VISTA HAVEN PL	91403	4	159B145   124	2279020003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.13537	-118.46924	NEW ROOF MOUNTED 11.88 KW (DC) / 10.4 KW (AC) PV SYSTEM WITH 36 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55942	16041-20000-16675	2140 S BUTLER AVE	90025	11	123B153    83	4260004030	(T)(Q)C2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			05/12/2016 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	11/23/2021 12:00:00 AM	ADDRESS	34.03687	-118.44429	Plan check for new 77 units appartment 5 story building. Service 3,200A.Building permit # 16010-10000-00799Note: Fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55943	12041-10000-09390	19045 W VANOWEN ST	91335	3	183B121  1079	2129025020	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1325.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.1941	-118.54866	Plan check for installation of roof mounted 9.5KW photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55944	16041-20000-20000	5525 N ETIWANDA AVE Suite 110	91356	3	174B125   518	2160011026	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.17048	-118.53094	TI to (E) medical office.  Plan check for power and energy.  2063 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55945	19041-20001-51430	11200 W PICO BLVD	90064	5	123B153   155	4256010012	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	06/25/2020 12:00:00 AM	ADDRESS	34.03581	-118.43706	Expedited plan check fee. PV3.  Install 226.4 kW DC roof mounted PV system.  (566) modules with (9) 20 kW inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55946	16041-10000-13547	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Closed	07/15/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR EMERGENCY LIGHTING FOR A TEMPORARY CONSTRUCTION SITE. SCOPE INCLUDES TEMPORARY LIGHTING AND EXIT SIGNS FOR EMERGENCY LIGHTING TO AN EXISTING COMMERCIAL MALL. EMERGENCY LIGHTING AND EXIT SIGNS WILL BE REMOVED AFTER CONSTRUCTION HAS ENDED. TITLE 24 IS EXEMPT DUE TO THE REMOVAL OF THE BARRICADE ALONG WITH THE EMERGENCY LIGHTS AND EXIT SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55947	19041-20000-08039	22565 W UHEA ROAD	91364	3	168B097   823	2076015064	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.15232	-118.61936	Plan check for PV roof mounted system, system size: 11.71KW AC CEC, 12.54KW DC with 38 PV Modules and 1 inverter(11.5KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55948	10041-10000-15493	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	03/11/2011 12:00:00 AM	ADDRESS	34.09786	-118.29745	INSTALLATIONS OF 2 EA CHILLERS, 2 EA COOLING TOWERS, AND COOLING PUMPS AT THE KAISER PERMANENTE PLANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55949	15041-20000-05079	10825 N SEPULVEDA BLVD	91345	7	207B145   135	2664013023	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			Corrections Issued	02/20/2015 12:00:00 AM	ADDRESS	34.26687	-118.46769	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOMS. 455 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55950	19041-20000-22471	7414 S LA SALLE AVE	90047	8	102B193  1810	6018013004	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.97225	-118.3056	PLAN CHECK FOR NEW 13.5KWH ESS SYSTEM WITH ADDITIONAL PV TO EXISITNG PV SYSTEM ON EXISTING SFD. INSTALLED ADDITIONAL SYSTEM SIZE 1.28KW DC/11.6KW AC. SCOPE OF WORK INCLUDES (4) SILFAB PV MODULES WITH ENPHASE IQ7+ INVERTERS, (2) NEW 125A PANELS, AND A 13.5KWH TESLA POWERWALL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55951	14041-10000-17044	600 WORLD WAY TER # 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	TERMINAL 6 POWER DISTRIBUTION SYSTEM UPGRADEREPLACE PANEL AND DISTRIBUTION BOARDS AS NEW MV SERVICE WAS PERMITTED UNDER SEPARATE APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55952	19041-10001-13802	9543 S COMPTON AVE	90002	15	093A213   172	6048004046	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			10/15/2019 12:00:00 AM			PC Approved	10/15/2019 12:00:00 AM	ADDRESS	33.94954	-118.24646	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES REVISING THE LIGHTING LAYOUT, T24 FORMS HAVE BEEN UPDATED ACCORDINGLY. ALL CHANGES ARE CLOUDED UNDER DELTA 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55953	13041-20000-36214	1526 S ARMACOST AVE	90025	11	126B145   564	4263033021	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.04116	-118.45944	PLANCHECK FOR NEW 26 UNIT APARTMENT W/ GARAGE. 4 STORIES OF TYPE IIIA  OVER TWO LEVELS (BASEMENT AND 1ST FLOOR) OF TYPE I GARAGE AND RESIDENTIALpc for power and energy. fire alarm variance has been filed))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55954	11041-10000-18005	400 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	title 24 and energy for a room in termial 4 A.A , small portion for outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55955	19041-10000-49684	7132 N SALISBURY ROAD	91307	12	183B089    79	2028039025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.20088	-118.65229	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 27  (SILFAB SLA-M300) MODULES, 27  (SOLAREDGE P320) OPTIMIZERS, 1 (SE7600H-US) CENTRAL INVERTER, CONNECTED TO A NEW 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 8.1KW DC & 7.6KW AC.MAIN PANEL UPGRADE TO BE PULLED UNDER SEPERATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55956	16041-20000-45798	1724 N ORANGE GROVE AVE	90046	4	147B177   224	5551008016	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.10231	-118.36034	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (15) AC PV modules and (1) load center. System is interconnecting with a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55957	15041-20000-28643	7917 S MAIN ST	90003	9	099B201   650	6031024015	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Expired	12/05/2017 12:00:00 AM	ADDRESS	33.96737	-118.27406	PV1. Install roof mounted PV system sized 2.5 kW. Interconnected with main service panel.(9) LG280 Modules(1) ABB UNO-2.5 Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55958	13041-10001-32414	1822 W 50TH ST	90062	8	111B193  1146	5015007005	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	33.99788	-118.3121	Expedited RSES plan check per applicant request.(((PV1, Install 1.5 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter.  Power-One Aurora PVI-3.0-0utd-s-us. 6 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55959	16041-20000-37490	1534 W FLORENCE AVE	90047	8	102B193  1368	6018005030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	33.97441	-118.30372	pv2install roof mounted pv sytem sized 10kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55960	10041-20000-12472	11947 W SUNSHINE TER	91604	2	162B169   838	2369021013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.1376	-118.39182	new single family house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55961	12041-20001-13338	6350 W SANTA MONICA BLVD	90038	4	144B185   733	5533016002	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.0906	-118.32785	Changes to approved set of plans. Small changes to lighting (employee cafe/kitchen) and addition of six branch circuits, one 100A panel, and one 4.6kW equipment. Plan check for power and energy. Low-rise commercial. 24296 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55962	19041-10000-51277	2207 W COLORADO BLVD	90041	14	162A221    66	5671013025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	02/22/2021 12:00:00 AM	ADDRESS	34.13936	-118.21434	Replacing Existing outdoor HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55963	19041-20000-26899	6922 W HOLLYWOOD BLVD 12th flr	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.10137	-118.34103	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55964	17041-10000-36904	8724 N BRADLEY AVE	91352	6	195B173   459	2408026035	[T][Q]M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.22816	-118.37405	PC for new FA system for single story building. Installing 20 devices, new FACP and one annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55965	13041-20001-15958	2023 S PARNELL AVE PV-1	90025	5	129B157   655	4321006036	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Expired	09/11/2015 12:00:00 AM	ADDRESS	34.04973	-118.4275	PV-1. Two 6kW inverters for 12kW total. Transformerless.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55966	16041-20000-33394	7551 W BEVERLY BLVD	90036	5	138B177   404	5526041012	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.0763	-118.35448	TI to (E) automotive shop.  Plan check for energy.  Indoor lighting and outlets in waiting room, restroom, and storage only per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55967	12041-10000-10165	6753 W HOLLYWOOD BLVD part B	90028	13	148-5A185  97	5547011015	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.10172	-118.33758	title 24 and emergency lighting, 7 stories not a high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55968	18041-10000-28177	333 S GRAND AVE 1710&1711	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	T-24, PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES INTERIOR TI TO AN EXISTING OFFICE SPACE IN A HIGH RISE BUILDING. NEW LIGHTING AND RECEPTACLE LOAD, TOTAL SQ.FT. 9024.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55969	11041-10000-10222	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	05/18/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	title 24 and emergency lighting.  OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55970	14041-20000-19202	18642 W CANTARA ST	91335	12	192B121   932	2103006014	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.21916	-118.53996	PV1Central/String Inverter standard plan.Install roof-mounted solar array on SFD. System size: 6kW.(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(25) SolarEdge P300 power optimizers(25) Trina Solar TSM-255 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55971	15041-30000-38151	5000 S CENTINELA AVE 316	90230	11	105B161    54	4221022***	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Apartment			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	PIN	33.98705865	-118.41416731	REPLACE FLOURESCENT WITH LED LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55972	13041-10000-01604	20520 W GRESHAM ST	91306	12	195B109   137	2780010009	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.23052	-118.58042	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. TOTAL OF 10KW WITH 41 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55973	16041-10000-20314	19600 W PLUMMER ST	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.2426	-118.5602	Plan check for power and Title 24.  Total area = 1,861 sq. ft.     T.I. to existing health care building.  New sub-panel, receptacles, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55974	18041-30000-07164	2029 S CENTURY PARK EAST 41st Floor-lobby	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing space elevator lobby on 41st floor. Total area: 295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55975	14041-20000-07452	10700 W SANTA MONICA BLVD 3rd. floor	90025	5	129B157   367	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	Install lighting on 3rd floor corridor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55976	18041-10000-46414	2640 N CAHUENGA BLVD EAST	90068	4	153A185    22	5577023904	[Q]PF-1XL-H	South Valley	Hollywood	Hollywood Hills West, Hollywood United	Yes	1897.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.11522	-118.3359	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55977	17041-20000-28149	511 S KENMORE AVE	90020	10	135B197   809	5502020008	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.06497	-118.29682	Plan check for roof-mounted solar pv system on apartment building.24.6kW ungrounded system (8.2+8.2+8.2). (97) 340W pv modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
55978	16041-20000-07579	7231 N ENSIGN AVE	91352	2	186B173  1099	2315025024	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.20229	-118.37159	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55979	16041-10000-06775	5670 W WILSHIRE BLVD 16TH FLR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.06222	-118.35208	T-24, TENANT IMPORVEMENT TO AN OFFICE SPACE IN THE 16TH FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 5180.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55980	18041-10000-29186	660 S FIGUEROA ST #2220	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	TI IN AN EXISTING OFFICE AREA IN SUITE #2220. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-07238	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55981	11041-10000-27243	1550 N CAHUENGA BLVD	90028	13	148-5A187 345	5546012400	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM			PC Approved	12/21/2011 12:00:00 AM	ADDRESS	34.09942	-118.32908	PLAN CHECK T24 ENERGY FOR RESTAURANT WITH OUTDOOR DINING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55982	15041-20001-14731	6250 N TOPANGA CANYON BLVD F Ste 1580	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	9.30.2015 - Plan check for changes to approved set. Lighting system updated, recheck lighting compliance only. Delta 2 changes.[Plan check for 1st time tenant. Interior T.I. of retail store[VARGAS] within an existing shopping center to include new accessible employee restroom, new changing rooms and new storage room. Total area:1880 sq ft. SUITE 1580]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55983	19041-10002-33054	11966 W WAGNER ST	90230	11	108B161   222	4218007001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	33.99441	-118.41666	NEW 12KW ROOF MOUNTED PV SYSTEM WITH 39 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55984	18041-30000-40575	13445 N GLENOAKS BLVD	91342	7	225B145    79	2501021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.31638	-118.4614	Install new Fire alarm system, (1) FACP, (73) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55985	17041-10000-09297	1327 W 64TH ST	90044	8	105B197  1176	6003034018	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Expired	05/21/2020 12:00:00 AM	ADDRESS	33.98153	-118.29899	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 10425 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55986	12041-20000-29567	9710 N FRANKIRST AVE	91343	12	201B137   575	2677019049	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	12/24/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.24678	-118.4887	Plan check for single family dwelling PV system. 3 strings per inverter. 7.92kW ROOF MOUNTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55987	17041-20001-40678	7901 S HULBERT AVE	90293	11	099B153   136	4114007001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	33.96356	-118.43322	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (26) modules, (26) micro-inverters, (3) load centers, and (1) battery back-up system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55988	08041-10001-17216	452 S MAIN ST	90013	9	129A211   150	5148009011	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			01/24/2012 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.04697	-118.24801	changes to permitted set of plans-in all the units, the electric range was replaced by a gas range ( may require CO detector in each unit); new panelboards and circuitsPlan check power and energy for new 6 story mixed use apartment building (106 units).  Plan check was extended to allow obtainning permit until July 30, 2010.  Plan was reviewed based on the 2007 California Electrical Code, and 2008 California Energy Standard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55989	17041-10000-32517	10250 W SANTA MONICA BLVD # 1912	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan review for First tenant - Gerard Darel - in retail space #1912	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55990	10041-10000-25831	3980 W MARTIN LUTHER KING, JR BLVD UNIT#4	90008	10	117B181   606	5032007022	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	12/30/2010 12:00:00 AM	ADDRESS	34.01508	-118.34254	REPLACE/INSTALL LIGHTS, SWITCHES,  TO AN EXISTING CIRCUITS. EPC IS FOR ENERGY, T24 & EMERGENCY LIGHTS. UNIT#4OF 4 (PERMIT WAS PULLED UNDER# 10041-10000-23248)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55991	17041-20001-21338	3550 W WILSHIRE BLVD	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	ADDRESS	34.06157	-118.30226	Reduction of system size.  System reduced to (2263) modules with (10) PVI 60TL Solectria inverters.  Miscellaneous changes throughout. (((PV2. ROOFMOUNTED SOLAR SYSTEM.  PARKING CANOPY ON ROOF OF A PARKING STRUCTURE. 914.55 KW DC/809.08 KW AC CEC.(2814) PS325M PV MODULES(12) PVI 60TL SOLECTRIA)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55992	10041-20000-10720	11918 W SAN VICENTE BLVD	90049	11	129B145  1149	4265007036	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM			Corrections Issued	06/21/2010 12:00:00 AM	ADDRESS	34.05238	-118.4706	T.I RESTAURANT BY COMBINING TWO OTHER TENANT SPACES AND THEIR PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55993	18041-10001-31301	1202 N AVENUE 54	90042	14	154-5A227  57	5478023031	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	09/17/2018 12:00:00 AM	ADDRESS	34.11935	-118.19905	EXPEDITED PLANSPLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 10KVA USING CENTRAL INVERTER(SE 10000A-US) WITH 34 PANELS WITH (P400) OPTIMIZRS.APPLICATION TIED IN WITH 18041-10000-31315 SAME PROPERTY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
55994	16041-20000-38283	19901 W NORDHOFF ST	91324	12	195B113    15	2782037034	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	34.23201	-118.56708	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is lighting in packaging area. No hazardous locations per applicant/engineer. Total lighting area = 6,670 sq. ft.Note: Building application has been created under 16016-20000-25901	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55995	18041-20000-30350	1249 N SHADYBROOK DR	90210	5	144B157   140	4357017013	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.09363	-118.42976	Plan check for a PV1 roof-mounted PV system. System size is 17.98 kWdc/15.86 kWac-CEC and consists of (62) micro-inverters, (62) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
55996	10041-10000-01579	9700 N WOODMAN AVE SUITE 1 A	91331	6	201B149   343	2644024025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.00, 1193.10	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	ADDRESS	34.24599	-118.44723	Tenant expansion of an existing store.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55997	12041-10000-26569	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Approved	11/06/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	TITLE 24 PLAN CHECK ONLY. NO EMERGENCY LIGHTS.  LOBBY RE-IMAGING PROJECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
55998	19041-10000-46407	1308 W WILSHIRE BLVD	90017	1	130-5A207  11	5143014003	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	01/02/2020 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.05382	-118.26707	REMODEL  OF OFFICE BUILDINGSPLAN CHECK IS FOR TITLE 24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
55999	16041-30000-31121	1860 S WESTWOOD BLVD	90025	5	129B153   645	4321001102	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.04875	-118.43571	Plan check Title 24 only in existing space, remove outdoor HID lighting fixture and replace with new LED lighting fixture. Total area: 15,300 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56000	14041-10000-11258	620 N RAMPART BLVD	90026	13	139-5A205 286	5402010017	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.07608	-118.27222	PV1 Install roof-mounted solar array, interconnect with main panel.System size = 3 kW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56001	12041-10001-13693	205 S VERMONT AVE	90004	13	135B197    24	5518030022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.07015	-118.29188	SUPPLEMENTAL: T24 CHANGE LTG AND ADD LTGCHANGE OF USE FROM EXISTING RETAIL TO RESTAURANT (1406  SQ FT): NEW ADA UNI-SEX RESTROOM, NEW NON-BEARING PARTITIONS. (NON-ALCOHOL SALE)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56002	17041-30000-44116	12126 W WATERFRONT DR	90094	11	105B161  1203	4211010119	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	33.98076	-118.40716	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 7,062 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56003	16041-20000-19005	3480 N CAHUENGA BLVD	90068	4	159B177   238	2425001073	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.13295	-118.35549	Plan check title 24 outdoor courtyard lighting remodel. Total outdoor area: 4,571 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56004	16041-20001-40358	2604 S ANCHOVY AVE	90732	15	012B189   548	7563036014	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	33.72508	-118.32142	Expedited per applicant requestPlan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (40) modules, (40) micro-inverters, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56005	15041-10000-29241	907 E 3RD ST	90012	14	129A215   266	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	PIN	34.0461867	-118.23487077	full plan check for HWS LA, aadaptive rebuild for wharehouse. The original contractor is changed. plan check is required based on new engineer.<<PC FOR POWER AND ENERGY. CHANGE OF USE FROM MANUFACTURING TO GALLERY. ADDITION 1000A TO EXISTIN 1200A SERVICE. TOTAL AREA(CONDITIONED AND UNCONDITIONED) 116005 SQ FT. PHASE 2 OF PROJECT WITH APP# 14041-10000-33875.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56006	13041-10001-30905	12945 W CORCORAN ST	91340	7	216B161   135	2514010059	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.28907	-118.4152	Expedited RSES plan check per applicant request. (((PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 16 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56007	17041-20000-44997	327 N CHESTNUT AVE	90042	14	153A233    90	5493031004	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.11489	-118.1752	INSTALLATION OF TESLA POWERWALL ENERGY STORAGE SYSTEM . 27 KWH +  PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.575 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56008	19041-10000-53020	444 W UNIVERSAL HOLLYWOOD DR	91608	4	162B177   616	2424044037	[Q]C2-1-SN	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		3200.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	10/21/2021 12:00:00 AM		Issued	10/21/2021 12:00:00 AM	PIN	34.1391226	-118.35899994	FULL PC FOR A FIRST TIME TENANT TO A CORE AND SHELL. TOTAL AFFECTED AREA 25965sqft. SOPE OF WORK INCLUDES ADDITION OF NEW PANELS AND CKTS.************************************************************************************PER BUILDING APPLICATION#19016-70000-40735:INTERIOR TENANT IMPROVEMENT WITHIN PORTIONS OF LEVEL 1, 2,  AND 7	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56009	17041-20000-35687	3746 N HAWLEY AVE	90032	13	159B205   752	5594010016	(Q)RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Expired	09/13/2023 12:00:00 AM	ADDRESS	34.09066	-118.19042	expeditepv1install roof mounted pv system sized 3.8kw with powerwall (battery back-up) interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56010	13041-10000-15910	928 S WESTERN AVE 225 & 226	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/17/2013 12:00:00 AM	ADDRESS	34.05485	-118.30886	Retail TI for suites 225 and 226 for jewelry store in a 3-story shopping center.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56011	16041-10001-03725			12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	PIN	34.23996545	-118.55452285	6/24/16: Changes to approved set, noted under Delta-4 and Delta 5. This is Plan chek only, permit shall be under the Master E#.*Note: There's change in Engineer under this plan, owner's letter is attached.<<Plan check for Title 24 only. Project site is a tenant space with an existing mall. Project scope is a tenant improvement. Total lighting area = 4,309 sq. ft.Note: Building application has been created under 15016-20000-27568>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56012	18041-10001-39377	802 E E ST	90744	15	030B209  1216	7424015063	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	33.77585	-118.25274	Changes to an approved set of plans, Changes include the addition of fixtures and space layout. Plan Check only.(((PLAN CHECK FOR A ADDITION TO AN EXISTING SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES ON THE 2ND AND 3RD FLOOR. TOTAL SQ. FT. 5535.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56013	13041-10000-06035	1331 N WATERLOO ST	90026	13	141A207   127	5424023005	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			03/07/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.08135	-118.26535	PHOTOVOLTAIC SYSTEM FOR MULTIFAMIYL DWELLING. TOTAL SYSTEM SIZE 1.68 KW. THIS APPLICATION IS PART OF A SERIES OF 3. DUE TO THE COMPLEX NATURE OF THE METERING SECTION, BACK ROOM WAS RECOMMENDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56014	16041-10000-39765	3600 N BARHAM BLVD W	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.13829	-118.34154	PC FOR ADDITION OF LAUNDRY CIRCUIT WHICH IS COMBO UNIT WASHER AND ELECTRIC DRYER. TOTAL OF 182 UNITS BEING ALTERED. FULL PC FOR NEW CONNECTED LOADS GREATER THAN 400A this is permit for unit w	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56015	16041-20000-02663	1525 N GOWER ST	90028	13	148-5A189 330	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Issued	03/18/2016 12:00:00 AM	ADDRESS	34.09849	-118.32256	Plan check for 1st time tenant for power and energy Tender Fender-Hollywood 2 story office building existing service and generator. Total area: 21,379 sq ft.Note: Building plan check is under 16016-10000-01289Note: Electrical Core and shell have been done on Application # 13041-20000-33082	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56016	18041-20000-30639	6923 N WISH AVE	91406	6	183B133   691	2230002021	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Issued	08/21/2018 12:00:00 AM	ADDRESS	34.1963	-118.50706	new 600 amp serive for new guest house and reconnect to existing main house. plan check for power only. this is plan check only.permit fees paid under building combo permit 18010-10000-02966	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56017	14041-20000-26885	13615 N MARCHANT AVE	91342	7	228B161   564	2580003031	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.32055	-118.40681	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3KW INTERCONNECTED WITH MSP.(20) SUN MODULE SW 270(20) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56018	19041-10000-31160	806 E 61ST ST	90001	9	105B205   594	6007009014	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	03/18/2020 12:00:00 AM		Permit Finaled	07/02/2020 12:00:00 AM	ADDRESS	33.98431	-118.26099	PLAN CHECK FOR ENERGY ONLY TO A WAREHOUSE TENANT IMPROVEMENT FOR NEW PARTITIONS, NEW ACCESSIBLE RESTROOMS AND EXTERIOR ALTERATIONS. SCOPE OF WORK INLCUDES NEW LIGHTING AND RECEPTACLES. SERVICE IS PLAN CHECK UNDER SEPARATE APPLICATION # 19041-10000-23889.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56019	17041-10001-30926	4755 S ALLA ROAD	90292	11	105B157   549	4212007006	P-1, [Q]MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	33.9835	-118.43032	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE  REVISING FLOOR PLANS, ADDING/RELOCATING RECEPTACLES, AND REVISING PANEL SCHEDULE. NOTE: PERMIT WILL BE PULLED UNDER APPLICATION 17041-10000-30926	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56020	18041-10000-45081	12121 W BLUFF CREEK DR STE  250	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	33.97874	-118.40463	PLAN CHECK FOR TITLE 24 ONLY FOR COMMERCIAL SCOPE OF WORK INCLUDES 9539 SQFT AREA.BLD# 18016-10000-33764	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56021	14041-10000-05912	13603 W MARINA POINTE DR	90292	11	105B153    74	4229003066	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.98559	-118.44433	REPLACING 1 FIREALARM PANEL TYPE EST2 WITH EST3 IN GARAGE LEVEL. SAME MANUFACTURER AND 1  GRAPHIC ANNUNCIATOR PANEL.  ALL DEVICES ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56022	12041-10000-24724	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.05886	-118.41642	RENOVATION OF EXISTING OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56023	19041-30000-38345	21550 W OXNARD ST STE 980	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.179	-118.60001	PC for t-24, Interior to (E) office suite 980.  Scope of work includes new lighting and receptacles in an existing space. Total sq. ft. 1199.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56024	16041-10000-09625	7038 W SUNSET BLVD	90028	4	147B181   698	5548017023	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Expired	05/03/2018 12:00:00 AM	ADDRESS	34.0978	-118.34294	T-24, TI TO AN (E) RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING FOR INDOOR AND OUTDOOR SPACES AND RECEPTACLES. TOTAL SQ. FT. 5653.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56025	13041-20001-30768	7192 W ESTEPA DR PV1	91042	7	198B197   121	2562021007	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2013 12:00:00 AM			Corrections Issued	11/09/2013 12:00:00 AM	ADDRESS	34.24227	-118.28902	Fees for Expedite only.<<New 18.639kw Photovoltaic System on the roof of an existing single family dwelling.  System is UNGROUNDED.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56026	17041-20000-43064	20700 W SESNON BLVD	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Issued	11/30/2017 12:00:00 AM	ADDRESS	34.29545	-118.58467	pv1install roof mounted pv system sized 5.7kw interconnected with msp.new development, general site address to be updated accordingly.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56027	19041-10000-01572	17025 W CALAHAN ST	91325	12	198B133   558	2692019020	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.2365	-118.50343	PV1. ROOF MOUNTED 9135 kw DC SYSTEM WITH (29) MODULES , (1) AC INVERTER 6 KW POWER OUTPUT,  (29) POWER OPTIMIZERS P320.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56028	16041-10000-05084	8045 N LANKERSHIM BLVD	91605	6	189B169   119	2310007030	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.21687	-118.38798	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW OUTDOOR LIGHTING FOR AN (E) RESTAURANT, MCDONALDS. TOTAL SQ. FT. 520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56029	16041-10000-20534	400 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.04446	-118.25616	Core and shell with service upgrade to 2000A.  New house panel and conduit for three future tenants.  Change of use from Night Club and Restaurant to Restaurant with future interior and exterior alterations done under separate permits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56030	17041-10000-08208	929 W JEFFERSON BLVD	90007	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING FEDEX OFFICE/RETAIL SPACE. TOTAL AFFECTED AREA IS 2601 SQ. FT. B#17041-10000-08208	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56031	18041-10000-45086	4320 S VERMONT AVE	90037	9	114B197  1198	5020035019	[Q]C2-1VL	South Los Angeles	South Los Angeles	Voices		2317.10	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.0049	-118.29134	T-24 ENERGY ONLY TI FOR RESTROOMS IN MARKET. NO CHANGE OF USE. SCOPE INCLUDES NEW SERVICE, PANEL LIGHTING AND RECEPTACLES. TOTAL EFFECTED AREA IS 1633 SQ.FTPORTION OF THE FEES ARE PAID UNDER 18041-70000-33310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56032	18041-20001-46378	346 N LAUREL AVE pv1	90048	5	138B177   180	5527034005	R1V3	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	34.07744	-118.36464	12/6/2018change of word description to include 15.84KW DC.department error $0.00 fee.((((pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56033	14041-10000-19839	500 WORLD WAY 4thFloor	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	33.94248	-118.40461	plan check for power and energy. 4th floor. Delta airline Terminal 5 SKYCLUB Renovations. Changes include clarifications on T24 and 100% rated breakers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56034	13041-10000-34876	8500 W BEVERLY BLVD Space 792	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I. OF AN (E) 8,500 S.F. RETAIL SPACE. plan chk is for title 24 and 2 ea emergency ckts	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56035	18041-10000-12870	1228 W SUNSET BLVD	90026	1	136-5A211 140	5405023014	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.06906	-118.25063	TI IN AN EXISTING RESTAURANT. T-24 ENERGY ONLY. TOTAL AFFECTED AREA IS 1155 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56036	18041-20000-33066	13121 N PORTOLA WAY	91342	7	225B165    19	2580018***	RD6-1XL	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.31104	-118.40531	Plan check for PV roof mounted system, system size: 5.76kW AC with 18 pv modules and 18 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56037	12041-10000-16215	14257 W CHANDLER BLVD	91401	2	171B153    72	2245024036	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	ADDRESS	34.16871	-118.44399	New rooftop 9.90kw photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56038	11041-20000-04375	5900 W WILSHIRE BLVD LOBBY	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM			PC Approved	03/07/2011 12:00:00 AM	ADDRESS	34.06237	-118.35809	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR INTERIOR TENANT IMPROVEMENT ON  GROUND FLOOR LOBBY LOUNGE AREA. EXISTING PERMIT #11041-90000-03953	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56039	19041-20000-36917	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	09/29/2020 12:00:00 AM	ADDRESS	34.10137	-118.34182	TENANT IMPROVEMENT ADD NEW PANELS, EQUIPMENTS,  AND LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56040	15041-20000-07240	6250 N TOPANGA CANYON BLVD #F1520	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for first time tenant power and energy (susiecakes).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56041	16041-20000-14360	16633 W VENTURA BLVD Ste 1050	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	TI to (E) commercial tenant space in commercial highrise building.  Plan check for energy.  1745 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56042	14041-20000-24318	15211 W VANOWEN ST Ste 206	91405	6	183B145   702	2220020020	(Q)C2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Issued	09/18/2014 12:00:00 AM	ADDRESS	34.19412	-118.46446	TI to (E) commercial medical office.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56043	14041-20000-35510	1940 CENTURY PARK EAST	90067	5	132B161    17	4319001007	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	PIN	34.06086276	-118.41331133	TI TO AN EXISTING 4 STORY CHILD CARE CENTER. SCOPE OFWORK TO BE PERFORMED ON THE THIRD FLOOR ONLY.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS.  TOTAL SQUARE FOOTAGE 950. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56044	16041-20000-09178	1250 N BEL-AIR ROAD	90077	5	147A153   463	4370029011	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.09618	-118.44375	PLANCHECK FOR SINGLE FAMILY RESIDENCE.  SERVICE UPGRADE AND NEW ELECTRICAL SYSTEMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56045	15041-10000-02193	425 S SHATTO PL	90020	13	135B197   648	5077003025	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.06611	-118.29014	Plan check for a new fire alarm system to be installed in a high-rise office building consisting of (6) floors. System consists of (238) devices, (8) RPSs, and (1) FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56046	10041-10000-16121	6842 N VAN NUYS BLVD 7th & 8th-Flrs	91405	6	183B149   647	2217009011	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM			PC Info Complete	08/17/2010 12:00:00 AM	ADDRESS	34.19499	-118.44846	T.I. to existing high rise building (7th & 8TH FloorS).  Install general/emergency lighting.   Plan check for  T-24 energy and emergency lights only.  Complete EPC may be required subject to field inspection.  Variance was filed to seperate the Fire Life Safety System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56047	10041-10000-15175	116 N ROBERTSON BLVD # 808	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	ADDRESS	34.0758	-118.38356	REMODEL SPACE TO THAT OF AN OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56048	12041-10000-18755	347 S BROADWAY	90013	14	130-5A211 143	5149015021	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.05004	-118.24923	Two new exterior lights and one circuit for a future sign for a shell building.  PLAN CHECK ONLY for Energy for the exterior light and sign.  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56049	18041-10000-34128	3807 W 6TH ST	90020	10	135B193   833	5503021023	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.06367	-118.30577	CHANGE OF USE FROM RETAIL TO ICE CREAM PARLORFULL PLAN REVIEW	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56050	10041-20001-06004	15840 W MONTE ST B-109	91342	7	225B141  1523	2604003036	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM			PC Approved	05/14/2010 12:00:00 AM	ADDRESS	34.31015	-118.47604	PLAN CHECK FOR DELTA 1 REVISION ONLY TO T-24 ENERGY OFFICE T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56051	11041-20000-26339	2235 N HERCULES DR	90046	4	150B177    26	5569007070	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2011 12:00:00 AM	01/12/2012 12:00:00 AM		Issued	01/12/2012 12:00:00 AM	ADDRESS	34.1112	-118.36484	New photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56052	12041-20000-10244	6600 N TOPANGA CANYON BLVD #1002	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM			PC Approved	06/18/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24 and emergency lighting plan check for space 1002.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56053	13041-10001-27759	20163 W VIA MEDICI	91326	12	219B113    53	2701041018	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.29453	-118.57286	PV1 6KWdc. 240V. negative GND. STD. 1story. Roofmount. [(1) inverters: {Fronius IG 5100}]. [(24)modules: {Trina {TSM-250PA05.08}}]     'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56054	09041-30001-21674	11748 W RIVERSIDE DR	91607	2	168B169   503	2355019037	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	01/19/2010 12:00:00 AM		Permit Finaled	03/30/2010 12:00:00 AM	ADDRESS	34.15739	-118.38936	1-19-10 - Supplemental is for plan recheck after original plans lost.  P/C is for Energy only :: TI in an existing office building. plan check is for title 24 energy calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56055	12041-10000-03575	11725 N SIERRA MORENA CT	91326	12	213B121    67	2872013036	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.28399	-118.53958	INSTALL A NEW 5KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56056	19041-20000-23217	529 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.04871	-118.25495	ti to an existing commercial building.  replacing existing light fixtures with LED.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56057	18041-10000-34881	6901 S MAIN ST	90003	9	102B201   485	6012009065	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.10	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	33.9772	-118.27422	NEW CONSTRUCTION - 4 STORY, 50 UNIT,  AFFORDABLE APARTMENT BUILDING. 1 LEVEL OF TYPE 1 PARKING STRUCTURE AND 3 LEVELS. SCOPE OF WORK INCLUDES NEW 120/208, 2500A SERVICE WITH TWO 1200AMP DISTRIBUTION BOARDS FOR TENANTS AND HOUSE LOADS. 5 TYPICAL UNITS. TOTAL SQ. FT. 89470 OUTDOOR AND 26115 INDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56058	10041-10000-06683	4324 W JEFFERSON BLVD	90016	10	120B181   776	5046008002	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Public Safety Only			04/13/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.02541	-118.34366	INSTALL A NEW FIRE LIFE SAFETY SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56059	13041-10001-35964	1361 W 190TH ST STE 120	90248	15	060B193   382	7351001020	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM			PC Approved	10/01/2014 12:00:00 AM	ADDRESS	33.85852	-118.3026	CHANGE TO APPROVED SET, ALL CHANGES APPLY TO EMERGENCY LIGHT RELOCATION OF G AND H FIXTURES.(((T.I. to existing Autozone store.  New 800A service, panels, branch circuits, and lighting.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56060	11041-20000-21609	10118 N SAN FERNANDO ROAD	91331	7	204B161   473	2537010002	[Q]CM-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	01/18/2012 12:00:00 AM	ADDRESS	34.25423	-118.40867	Plan check power and energy for TI of core & shell, sign ckts are future.   Unit 2 thru 8 currently not occupied. Core & shell under #10041-20000-20455. Unit 1 first time tenant under #11041-20000-17660	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56061	15041-10001-32099	935 N HUDSON AVE	90038	13	144B185  1027	5533023005	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM			PC Approved	09/22/2016 12:00:00 AM	ADDRESS	34.08815	-118.33232	CHANGES TO APPROVED SET.CHANGES INCLUDE RELOCATION OF SERVICE,  LOAD CALC FROM MAIN SERVICE,  ADDITION OF ELECTRIC OVEN AND LED LIGHTING IN THE KITCHEN. SOME ADDITIONAL MINOR CHANGES ALSO BEING MODIFIED ON THE FLOOR PLAN.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56062	13041-10000-29595	1575 N QUEENS ROAD	90069	4	147B173    40	5559025002	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.09896	-118.37732	PV1.  Install 12.5 kW DC roof-mounted photovoltaic system to interconnect with main service panel using Fronius IG Plus V 11.4.  50 modules: HANWHA # HSL60P6-PB-4-250TW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56063	19041-10000-11747	18460 W ROSCOE BLVD	91325	12	192B125   934	2102001018	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.22046	-118.53569	PC FOR NEW FA SYSTEM IN A 3 STORY BUILDING. SCOPE INCLUDES 240 DEVICES AND 3 PANELS (1 FACP AND 2 BPS'S)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56064	15041-20000-02797	12473 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.97916	-118.41034	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56065	17041-20000-18407	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM			PC Info Complete	06/02/2017 12:00:00 AM	ADDRESS	34.07666	-118.3805	plan check for outdoor lighting only.  adding new lighting new controls to existing panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56066	12041-20000-18953	111 E UNIVERSAL HOLLYWOOD DR #2100	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	Install power circuits and lighting circuits for connection of new and relocated lighting.  Emergency circuit is existing. T-24 and emergency lighting plan check for remodeled space. TENANT IMPROVEMENT TO SUITE # 2100 OF (E) OFFICE BUILDING: -  NEW DEMISING WALL, NEW INTERIOR PARTITIONS, NEW SINK;  EXISTING ACOUSTIC TILE AND GRID TO REMAIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56067	13041-20002-25612	7479 N WESTCLIFF DR	91304	12	186B089   312	2027045013	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	PIN	34.20703816	-118.64845321	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.6 KW AC USING TRANSFORMERLESS INVERTERS. 2 CENTRAL INVERTERS. 4 STRINGS/ INVERTER. NONSTANDARD PLAN.(((changes to approved set of plans. 4.2 kw inverter. clouded. ))) $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56068	14041-20000-11639	11358 W SHELDON ST	91352	7	201B173   124	2538023005	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.25037	-118.37842	PV1Install roof-mounted solar array on SFD. System size: 8kW(2) SMA American SB4000TL-US-22 transformerless inverter(33) ET Solar ET-P660250BB pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56069	12041-20000-18454	13310 W SHERMAN WAY	91605	2	183B157    92	2328025027	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.20097	-118.42324	NEW 48' x 124' 2 STORY BUILDING W/ CARWASH ON 1ST FLOOR AND OFFICE ON 2ND FLOOR.  Plan check for power, emergency lighting, and energy conservation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56070	16041-10000-26567	10923-10929 W WEYBURN AVE	90024	5	135B149   586	4363018011	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	07/07/2020 12:00:00 AM	ADDRESS	34.06274	-118.44623	Plean check for power and energy. TI to an (E) commercial building.  Replace 2000A main switchboard to create multi metering system for future tenants. Install new 200 Distribution panel. Total affected area for energy is 1,118 sq.ft.  Service size remain the same (2000A)(B# 16016-10000-17446)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56071	18041-10000-32413	5628 E KENDALL AVE	90032	14	147A239    41	5309026020	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.09851	-118.1574	NEW 12.095 KW (DC) ROOF MOUNTED PV SOLAR SYSTEM WITH 41 PV MODULES ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56072	16041-20000-44605	12622 W VANOWEN ST	91605	2	180B161    39	2325002040	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	Apartment			12/20/2016 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.19374	-118.40804	New 3-story 6-unit apartment building with private garage.  Connected load over 400A.  (2) new services - (1) 200A 240V 3ph and 400A 240V 1ph.  Plan check for power and energy.  Building permit under 16010-20000-01231	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56073	12041-20000-26798	2844 W ROWENA AVE Lot 3	90039	4	151-5A207 173	5434033010		East Los Angeles			YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.10762	-118.26616	Enphase system on roof of single family dwelling. Address is also 2846 Buzz Ct.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56074	16041-10000-27278	9775 S AIRPORT BLVD	90045	11	093B169   276	4124029031	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM			PC Approved	08/02/2016 12:00:00 AM	ADDRESS	33.9478	-118.38617	TITLE 24 FOR NEW CANOPY LIGHTING (AREA=2879) IN FRONT OF CAR RENTAL(AVIS BUDGET).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56075	13041-10000-33015	2834 S POTOMAC AVE	90016	10	123B181  1531	5057007016	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/10/2013 12:00:00 AM	ADDRESS	34.03005	-118.34379	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 3.5KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(14) TRINA SOLAR # TSM-250(14) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56076	19041-10001-10334	1208 W PASEO DEL MAR	90731	15	006B193   319	7470027025	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	33.71341	-118.30624	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE UPDATING EXISTING PV(MATCH INSTALLATION) AND UPDATE LOAD CENTER RATINGORIGINAL PERMIT PC to 1 ESS and a new panel to be connected to an existing PV System	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56077	10041-10000-25479	2636 S PORTLAND ST 1ST & 2ND-Floors	90007	9	123A201   237	5123002406	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM			Reviewed by Supervisor	03/15/2011 12:00:00 AM	ADDRESS	34.02981	-118.28258	TI ON THE FIRST AND SECOND FLOORS OF AN EXISTING DORMATORY IN USC.  PLAN CHECK IS FOR POWER.  15 EXISTING OLD PANELS ARE REPLACED WITH NEW PANELS AND 9 EXISTING FEEDERS ARE ALSO REPLACED WITH NEW FEEDERES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56078	13041-10000-21144	12652 W VILLAGE LANE bldg #3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56079	17041-20000-22615	624 S MANSFIELD AVE	90036	4	135B181   679	5507020028	R1R3-RG	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.06424	-118.34063	PV1.  Install 3.84 kW roof mounted grid tied PV system.  ACM standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56080	11041-20000-13424	635 S HARVARD BLVD 1st floor	90010	10	135B193  1017	5503027016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM	06/28/2011 12:00:00 AM		Issued	06/28/2011 12:00:00 AM	PIN	34.06214927	-118.30497205	Plan check T24 Energy general/emergency lighting for classrooms, toilet room, corridor on 1st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56081	16041-10000-16665	10880 W WILSHIRE BLVD SUITE 905	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.05885	-118.44283	TI TO SUITE 905. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56082	19041-10000-24680	1405 W 240TH ST	90710	15	042B193   742	7439009018	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	33.80718	-118.30119	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor )- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56083	16041-10000-35644	1888 S CENTURY PARK EAST	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Issued	10/24/2016 12:00:00 AM	ADDRESS	34.06104	-118.41402	Plan check for T24 only for TI for Bank offices. Scope of work includes new lights and receptacles with 9460 sqft. **TENANT IMPROVEMENT CREATE NEW OFFICE ROOMS AND STORAGE ROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56084	17041-10001-43487	1813 N AVENUE 53	90042	14	157-5A227 286	5479016020	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM			PC Approved	02/07/2018 12:00:00 AM	ADDRESS	34.12502	-118.19932	Expedited Fees per applicant,  Plan check for PV roof mounted system with battery back up system. Total system size: 6.5kW with 20 modules and 1 inverter(6.0kW) and 5.0KW Tesla battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56085	12041-10000-19776	4001 W WILSHIRE BLVD	90010	4	132B189    43	5504018018	[Q]C1.5-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM			PC Info Complete	09/19/2012 12:00:00 AM	ADDRESS	34.0619	-118.31433	CONVERT (2) RETAIL SPACES ( B & C ) TO RESTAURANT.  FULL PLAN CHK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56086	19041-10000-06325	610 W 6TH ST	90017	14	129A209   266	5144005125	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.04881	-118.25573	pc t-24 only. Interior tenant improvement to existing resataurant.  scope of work 1863sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56087	18041-10000-17059	603 E 115TH ST	90059	15	087A207   339	6072004027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	33.93021	-118.26482	*Zero permit fee due per AB-1414/ SB-1222*New rooftop solar system. System size is  33.48 kW AC CEC / 30 kW AC per inverter's size, with  93 PV Modules and 47 optimizers P730.(Building Permit Number: 18016-10000-14624)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56088	19041-10000-40132	1255 S ELDEN AVE	90006	1	129B197  1060	5076018024	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	01/22/2021 12:00:00 AM	ADDRESS	34.04755	-118.28789	NEW FIRE ALARM SYSTEM WITH 532 DEVICES..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56089	17041-10000-25575	335-337 N GLENDALE BLVD	90026	13	136-5A207 349	5159020024	C2-1VL	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.06652	-118.2607	T24 PLAN CHECK FOR TI(BAKERY) - TOTAL  AFFECTED AREA = 2487 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56090	12041-20000-14224	444 S FLOWER ST suite 2000	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	energy plan check suite 2000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56091	17041-10000-02319	300 S GRAND AVE LP-155	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	PIN	34.05243427	-118.25124731	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM (E) OFFICE TO COFFEE SHOP. SCOPE INCLUDES ONE NEW PANEL, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 836 SQ. FT.   B#16016-10000-29227	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56092	16041-10000-38598	5701 N LANKERSHIM BLVD	91601	2	174B169   579	2338022001	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.17417	-118.38045	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR LIGHTING). TOTAL AREA 4375 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56093	17041-20001-30992	4504 N BRUNSWICK AVE	90039	13	159B205   258	5593026010	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			PC Approved	09/08/2017 12:00:00 AM	ADDRESS	34.13362	-118.26912	expeditepv1install roof mounted pv system sized 3.8kw interconnected with msp.  center fed panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56094	15041-10000-43181	825 W STATLER ST	90731	15	024B197    66	7442003023	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	33.76395	-118.29708	PV1, ROOF MOUNTED SYSTEM WITH CENTRAL INVERTERS. (39) MODULES (2)  INVERTERS, 5KW  AND A 3KW-AC. TOTAL SIZE IS 8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56095	17041-20000-17097	3430 S DUNSMUIR AVE	90016	10	120B177   845	5047011025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.02448	-118.36224	Plan check for solar pv system, roof-mounted on SFD.4.16kW ungrounded system.(13) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56096	18041-20000-38194	700 S FLOWER ST ste 400	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	ti to an existing commercial building adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56097	17041-10001-01444	5343 W IMPERIAL HWY	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	33.93128	-118.37337	PERMIT ALREADY ISSUED. THIS IS PLAN CHECK FOR TEMP. 500KW GENERATOR. USING 600A FEEDER TO FEEDER PANELS APPROVED UNDER SEPARATE PERMIT FOR TEMP DURING CONSTRUCTION.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56098	17041-10001-04996	9410 N OWENSMOUTH AVE	91311	12	198B105    55	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Approved	06/23/2017 12:00:00 AM	ADDRESS	34.24138	-118.60168	CHANGES TO AN APPROVED SET OF PLANS - CHANGES INCLUDE ADDITION OF NEW SEALING FAN AND RELOCATION OF LIGHTS - CHANGES UNDER DELTA 1ORIGINAL PERMIT # 17041-10001-04996OFFICE AND FACTORY AREA TI. NEW MACHINES AND EQUIPMENT. PC FOR POWER AND ENERGY. NEW CONNECTED LOADS GREATER THAN 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56099	14041-20001-31963	12205 W VENTURA BLVD	91604	2	162B165   117	2367017007	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.14344	-118.39864	07-01-2015 Change to approve set of plan; Changes include relocate 800A distributaion equipment to a new room, changes apply to delta 2 only. [[[[[[Plan check for power only. Upgrade service from 400A to 800A. New service distribution equipment. New feeders to existing equipment and panels. 2 new panels. Commercial retail low rise building.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56100	16041-20000-30623	21650 W OXNARD ST Lobby	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for energy only. TI to existing elevator lobby. New lighting (incl. emergency). 664sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56101	11041-10000-20628	1110-1114 E LAKE ST BLDG 24	90291	11	111B145   161	4243001039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.00316	-118.45956	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56102	19041-10000-04050	6555 W BARTON AVE 100	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.08785	-118.33475	TI FOR FIRST FLOOR FIRST TIME TENTANT COMMERCIAL OFFICE, SCOPE OF WORK INCLUDES (1) 150A, (1) 100A PANEL, (1) 30KVA  AND (1) 45 KVA TRANSFORMER, T24, TOTAL SQFT'G = 2600 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56103	13041-10000-17954	1893 N LUCRETIA AVE	90026	13	142-5A211 100	5420032039	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.08557	-118.25003	PV1 2.45kw XFRMless. 2 STORY. nonSTD. ROOFMOUNT.  [ 1 INV: solaredge SE3000A-US] [ 10 MOD: TRINA TSM-245PC05} with optimizers]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56104	19041-20001-01778	1266 N BENEDICT CANYON DR	90210	5	144B157   234	4356028005	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.09156	-118.42791	PLAN CHECK ONLY FOR NEW ROOF TOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 7.15 KWDC/7.6 KW AC. SCOPE OF WORK INCLUDES (22) Q PEAK DUO-G5 325W PV MODULES WITH P370 OPTIMIZERS, AND (1) SE7600 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56105	16041-10000-28169	706 N CITRUS AVE	90038	5	141B185   553	5524012022	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Closed	11/17/2016 12:00:00 AM	ADDRESS	34.08374	-118.33955	PV2 roof mounted system with 5KW AC and (21) modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56106	19041-20000-49213	555 S MATEO ST BLDG 4	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	02/05/2021 12:00:00 AM		Permit Finaled	12/28/2021 12:00:00 AM	ADDRESS	34.03943	-118.23302	Power and lighting for storage area in commercial office building.  Plan check for power and energy.  2 separate electrical permits under same plan check approval:19041-20000-4921019041-20000-49212	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56107	18041-20000-41183	18864 W KILLOCH WAY	91326	12	216B121   162	2820015026	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.29126	-118.54457	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWdc/10.42 kWac-CEC and consists of (1) 10 kWac rated inverter and (38) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56108	11041-10000-24954	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.20	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	33.79072	-118.29449	T.I. to examination and procdure room of a medical office.  Plan check for POWER and ENERGY.  No suite number, per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56109	15041-10001-36479	2807 E BOULDER ST	90033	14	129A227   321	5178010023	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2015 12:00:00 AM			PC Approved	11/19/2015 12:00:00 AM	ADDRESS	34.0465	-118.20003	PC FOR PV SYSTEM INTERCONNECTION TO SUBPANEL. NONSTANDARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56110	13041-10000-09176	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	PIN	34.05182951	-118.41257696	New fire alarm system for 4-story Building 105 at 20th Century Fox Studios.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56111	16041-20002-08558	18133 W VENTURA BLVD 201	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	[[ 3/1/17  CHANGES TO APPROVED SET. DELTA 3 CHANGES ONLY.  REMOVING  INSTAHOT WATER HEATERS AND PANELBOARD. REDUCING HV2 MAIN BREAKER TO 800 AMPS]]]]]PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. 2ND FLOOR OF A 4-STORY MED BUILDING. Medical outpatient center. 13,973sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56112	15041-20000-21592	15602 W SIMONDS ST	91344	12	210B145    16	2662006031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.27615	-118.47187	Installation of new roof mounted solar PV array.  Total system size = 6.5 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56113	19041-20000-39206	7315 N RUTHERFORD HILL DR	91307	12	186B089   598	2027043020	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.20372	-118.65172	PV1.  Install 16.06 kW roof mounted grid tied PV system.  (44) modules with (2) 7.6 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56114	17041-20000-07330	1042 S GRAND AVE	90015	14	127-5A207 282	5139010005	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM			PC Info Complete	03/07/2017 12:00:00 AM	ADDRESS	34.04188	-118.26139	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 800 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56115	19041-10000-00436	6326 W LINDENHURST AVE	90048	5	135B177   331	5510020029	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.06612	-118.36579	INSTALLATION OF 1 ENERGY STORAGE SYSTEM TO PV PERMITTED. SCOPE INCLUDES: ONE LG CHEM RESU10H 9.8KWH BATTRY. SOLAREDGE AUTO TRANSFORMER, AND ONE PANEL.PV FEES WERE PAID UNDER THE ONLINE PERMIT NUMBER 18041-90000-29872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56116	14041-20001-07486	19648 W CRYSTAL RIDGE LANE	91326	12	219A117   402	2701012091	RD3-1, RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch		1082.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.29385	-118.56208	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING TRANSFORMERLESS INVERTER USING NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56117	14041-20000-21910	19641 W CRYSTAL HILLS DR	91326	12	219A117   245	2701013020	RD3-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch		1082.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Closed	03/12/2015 12:00:00 AM	ADDRESS	34.29481	-118.56198	pv1install roof mounted pv system sized 4.2kw interconnected with msp.(20) trina solar tsm-250 modules(1) ABB string inverter 4.2-tl	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56118	18041-10000-12555	1100 S GLENDON AVE PH 1	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	06/24/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	PLAN CHECK FOR TITLE 24 ONLY FOR TI FOR EXISTING OFFICE SPACE. TOTAL AFFECTED AREA = 2041 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56119	19041-10000-09170	12935 W ARROYO ST	91340	7	216B161    18	2514002***	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.29271	-118.41483	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56120	15041-10001-41493	200 N NORTH MAIN ST	90012	14	130-5A213 115	5161026023	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	07/07/2021 12:00:00 AM	ADDRESS	34.05326	-118.24219	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED. INCLUDES ENCLOSURE OF SERVER ROOM AND ADDITION OF 4 SUPPLY FANS. UPDATED LOAD CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56121	14041-20000-32155	15910 W VENTURA BLVD #801	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.15561	-118.47969	TI # 801	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56122	19041-10000-06692	907 S WESTWOOD BLVD	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.06335	-118.44565	PC T-24 only for TENANT IMPROVBEMENT TO UPS RETAIL. AREA OF SCOPE 690 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56123	12041-10000-09132	1034 S CATALINA ST	90006	10	129B197   357	5078012017	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Expired	08/05/2014 12:00:00 AM	ADDRESS	34.05171	-118.29462	Plan check for apartment bldg. PV system, 23.26KW. roof-mounted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56124	19041-20002-20650	1226 S ORANGE DR	90019	10	129B181   197	5084028029	R2-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.05266	-118.34514	08-26-2019, Changes to an permitted set of plan, changes include modify conductor size to: 10 AWG and 4 conductor in a raceway. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56125	19041-10000-03251	990 W 190TH ST 3rd Floor	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	33.85813	-118.29505	PC T-25 only for Full floor tenant improvement to (E) office suite (22,321 SF).  No change in occupancy or parking.  ((B# 19016-40000-02530))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56126	17041-30002-15490	1429 S WESTWOOD BLVD	90024	5	132B153   916	4324010009	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.05467	-118.44147	08-10-2017 Changes to an approved set of plan. Changes include remove scope of work. Changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56127	19041-10000-08674	107 N AVENUE 64	90042	14	153A231    78	5493014012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.11481	-118.18138	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56128	15041-10001-05839	1193 N PIEDRA MORADA DR	90272	11	135B117   107	4431032005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM			Reviewed by Supervisor	03/09/2015 12:00:00 AM	ADDRESS	34.06756	-118.55159	PV1.  Install 8.32 kW roof-mounted PV system.  (N) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56129	17041-20000-07457	7724 N LAUREL CANYON BLVD	91605	6	189B165  1031	2317001046	(T)(Q)R3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2017 12:00:00 AM			PC Info Complete	03/30/2017 12:00:00 AM	ADDRESS	34.21093	-118.39631	PV1.  Install 7.6 kW AC roof mounted grid tied PV system.  (49) modules with (1) 7.6 kW AC roof mounted.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56130	15041-10000-43107	6909 S VAN NESS AVE	90043	8	102B189   792	4008018028	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	PIN	33.9767712	-118.31803304	PV1, ROOF MOUNTED SOLAR SYSTEM. (12) MODULES AND (1) INVERTER. TOTAL SIZE 3.0 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56131	11041-10000-15377	16023 W VANOWEN ST 1-10	91406	6	183B141   768	2224028029	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	Apartment			07/22/2011 12:00:00 AM			Corrections Issued	07/22/2011 12:00:00 AM	ADDRESS	34.19409	-118.48217	FIRE ALARM SYSTEM FOR NEW TOWN HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56132	14041-20000-08063	14860 W ROSCOE BLVD	91402	6	192B149   421	2210003074	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			Corrections Issued	03/26/2014 12:00:00 AM	ADDRESS	34.22131	-118.4572	Install temporary portable MRI equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56133	14041-20000-21435	19941 W LORNE ST	91306	3	189B113   179	2106026012	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.2173	-118.56811	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(1) SOLAR EDGE SE6000 TRANSFORMERLESS INVERTER(33) TRINA SOLAR TSM255 MODULES(33) SOLAR EDGE OPTIMIZER P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56134	17041-20001-15684	19854 W BARBERRY LANE	91356	3	162B113    98	2180021005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM			PC Approved	05/24/2017 12:00:00 AM	ADDRESS	34.13977	-118.5667	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.6.6kW ungrounded system, (26) 315W pv modules.Interconnecting with an existing 7.5kW pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56135	12041-20000-29288	700 W WORLD WAY Terminal 7-Space 7C	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	PIN	33.94153561	-118.3984113	Plan check for power and energy. Terminal 7, Space 7C. 5936 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56136	19041-20003-04168	6245 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	(WC)TOPANGA-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.18421	-118.60617	10/3/19CHANGES TO APPROVED SET DELTA 5 ONLY ELECTRICAL DISTRIBUTION CONFIGURATION.<<<Service upgrade for (E) retail shell building.  1600A 480Y/277V service.  Building permit under 19016-20000-03245.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56137	11041-20000-23887	888 W 6TH ST 2ND FL	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/08/2011 12:00:00 AM			PC Approved	11/08/2011 12:00:00 AM	ADDRESS	34.05062	-118.25846	s.200 T.I.ENERGY, EMERGENCYFire/ Life safety is existing to remainexist. permit 11041-90000-23200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56138	18041-20000-02543	6253 N AUCKLAND AVE	91606	2	177B177    96	2414019011	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.18453	-118.36062	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  this is an addition to an existing pv system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56139	13041-10000-33143	4437 N SIMPSON AVE	91607	2	165B169   148	2364010018	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	ADDRESS	34.15143	-118.38901	PV1.  Install 4 kW roof-mounted PV system, interconnect with main service panel.  16 modules: Trina Solar TSM-250PA05.18.  Transformerless inverter: SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56140	13041-20000-19271	22223 W SCHOOLCRAFT ST	91303	3	183B101   504	2024035010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.19643	-118.61111	pv1 single family dwelling. total system size 4.3 kw. using microinverter standard plan. using total of 20 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56141	15041-20000-17258	13111 W KITTRIDGE ST	91606	2	180B161   654	2326013031	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	PIN	34.1899643	-118.41851723	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56142	10041-10000-07877	2580 N GLENDALE BLVD	90039	4	150A209   185	5438016002	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM			Corrections Issued	05/08/2010 12:00:00 AM	ADDRESS	34.10497	-118.25927	NEW CAR WASHcancell job by owner contractor left the job permit is under different application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56143	19041-10000-32088	6442 N PLATT AVE	91307	12	180B093   512	2036024053	(Q)C1-1VL, (Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL, C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.188	-118.64248	T-24 PLAN CHECK FOR TI TO BANK OF AMERICA PARKING AND CANOPY LIGHTING. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 43935 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56144	10041-10000-25768	1160 W HARRY BRIDGES BLVD	90744	15	027B201   208	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Public Safety Only			12/29/2010 12:00:00 AM			Corrections Issued	02/14/2011 12:00:00 AM	PIN	33.77018478	-118.27675111	NEW FIRE ALARM SYSTEM FOR 1-STORY DRIVER SERVICE BUILDING FOR THE PORT OF LA. EPC IS FOR POWER (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56145	16041-10000-44191	8500 W BEVERLY BLVD #601	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	Plan check Title 24 only in existing mall Beverly Center Space # 601 T.I. retail. Total area: 1,744 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56146	10041-20000-09422	10635 W SANTA MONICA BLVD Suite 170	90024	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood			2656.00	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	05/21/2010 12:00:00 AM		Permit Finaled	11/21/2010 12:00:00 AM	PIN	34.05365874	-118.43036269	Installing lighting in part of office area. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56147	18041-20000-26649	9014 N HASKELL AVE	91343	12	195B141   102	2672008***	[Q]RD5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.23403	-118.47614	Plan check for PV roof mounted system, system size: 8.71 KW AC CEC with 32 pv modules and 2 inverters(5.2KW) connected to 225A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56148	15041-10000-00343	550 S HOPE ST 8TH FLOOR	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/06/2015 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	PC FOR ENERGY ONLY. PARTIAL FLOOR OFFICE BUILD OUT. TOTAL AREA 7216 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56149	19041-10000-07925	1925 S CENTURY PARK EAST 10th Floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	Energy plan check for a tennant improvement to (e) commercial office building to create a  screening room. Scope includes new lighing and equipment with a total area of 504-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56150	17041-20000-29506	1880 S CENTURY PARK EAST Suite 215	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only. Project site is an existing tenant space in a commercial building. Project scope is a tenant improvement. Total lighting area = 807 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56151	13041-20000-20004	7859 N CRANER AVE	91352	2	189B173   482	2409010012	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	ADDRESS	34.21367	-118.36937	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW USING 20 MODULES. TRANSFORMERLESS INVERTER. 4 STRINGS PER INVERTER, BACK ROOM PC. NONSTANDARD PLAN. PERMIT TO INCLUDE SERVICE AND PANEL UPGRADE. extra circuit included for monitor system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56152	18041-20000-21372	1639 N NORTH MAIN ST	90012	1	136-5A217 151	5409003034	UI(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.06664	-118.22839	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES. 9525 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56153	15041-10002-34685	603 N ST LOUIS ST	90033	14	130-5A223 353	5175027001	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.05069	-118.21025	EXPEDITE PER CUSTOMER REQUEST.PV1.  Installation of 3.445 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56154	14041-10000-03106	8254 N WHITE OAK AVE UNIT 4	91325	12	192B129   323	2201001032	(Q)C2-1VL, C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.22073	-118.51841	Install T-bar ceiling and lighting for empty tenant space for future lease.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56155	18041-10000-02948	510 N BRONSON AVE	90004	4	141B189  1087	5522025008	R2-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.07923	-118.31774	PC for 8.28kW (AC) rooftop solar for SFD. Installing 24 AC modules and one load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56156	15041-20000-42081	5201 W 20TH ST	90016	10	126B177   953	5063001014	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Apartment			12/14/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.04046	-118.35441	PV1 on multi family dwellings (4 units). Roof mounted installation 3.8kW AC system.(10) Q-Pro BFR-G4 260(10) Power Optimizer SE-P300(1) Inverter SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56157	15041-10000-16285	200 WORLD WAY T-2-DEPT. LV.3	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	TI-24 TO (E) RETAIL STORE IN LAX. ADDING NEW LED LINEAR LIGHTING.  TOTAL SQ. FT. 300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56158	14041-20001-14897	20205 W STRATHERN ST	91306	3	189B113   447	2107017120	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.21571	-118.57323	((EXPEDITE FEES)))PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56159	14041-10000-14892	5826 W OLYMPIC BLVD	90019	4	132B177   757	5085003031	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			06/06/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.05724	-118.35691	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 15 DEVICES AND 1 PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56160	17041-20000-39920	15760 W VENTURA BLVD Suite 500	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check for energy only. TI to office suite 500 in high rise building. New lighting (incl. emergency) - 10,435sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56161	19041-30000-00858	2029 S CENTURY PARK EAST Ste 1130N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is an existing tenant space in a commercial building. Project scope is a tenant improvement. Total lighting area = 2,251 sq. ft.Note: Building application has been generated under 18016-10000-32653	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56162	16041-20000-22983	9620 N WHEATLAND AVE	91040	7	201B177   448	2544006052	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.2435	-118.35835	Plan check for PV roof mounted system. System size: 15.2kW with 56 modules and 2 inverters(7.6kW)Note: Fee $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56163	15041-10000-17325	960 E 3RD ST	90013	14	127-5A217  90	5163016015	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.04578	-118.23289	TI TO AN EXISITING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 8011.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56164	10041-20002-25118	1200 S SANTA FE AVE	90021	14	123A217   315	5166007011	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.02944	-118.22979	Clouded modification to approved plans.  To show new bathrooms.  No new lighting installed.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56165	17041-10000-27804	1710 N GLENDALE BLVD	90026	13	142-5A209  65	5423008016	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.08604	-118.25965	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY. TOTAL SQUARE FT 25150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56166	16041-20000-25627	5950 N CANOGA AVE SUITE 100	91367	3	177B105    93	2149002014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.17806	-118.59721	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR OFFICES. 2017 SQFT. SUITE 100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56167	17041-10001-36332	4227 W 59TH ST	90043	8	105B181   161	4019006029	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM			PC Approved	11/03/2017 12:00:00 AM	ADDRESS	33.9872	-118.34861	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE MICROINVERTER MODEL TYPE TO IQ6-PLUS-72  AND ROOF LAYOUT. __________________________PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.25KWdc / 4.830KWac. USING 21 MODULES AND MICROINVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56168	12041-20000-17102	14800 W VENTURA BLVD	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.15186	-118.45547	New generators for ATT building.  Electrical for building and energy for outdoor lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56169	19041-20000-43293	17323 W VENTURA BLVD	91316	5	171B133   685	2257016056	(Q)C4-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.16115	-118.51065	$0 FEE PER AB 1414. PV3.  Install 82.02 kW DC / 69.60 kW AC roof mounted grid tied PV system.  (228) modules with 100 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56170	17041-10000-41800	900 W WILSHIRE BLVD 15th floor	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR OFFICE TI IN A HIGH RISE BUILDING (15TH FLOOR) FOR T-24 ENERGY ONLY.SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTING. TOTAL AREA EFFECTED 16,958SQ-FTB#17016-70000-31977TI - non bearing interior partition on 15th floor.  No change in parking	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56171	10041-20000-10734	6300 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM	06/08/2010 12:00:00 AM		Permit Finaled	07/07/2010 12:00:00 AM	ADDRESS	34.18492	-118.59722	Lighting and power in existing office area. This P/C is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56172	16041-10000-40322	8015 S SEPULVEDA BLVD	90045	11	099B165   597	4108027007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	33.9664	-118.39647	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56173	12041-10000-22783	3200 W SAN FERNANDO ROAD	90065	13	153B209   352	5458002005	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.11652	-118.24791	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56174	12041-20000-22373	633 S LA BREA AVE	90036	4	135B181   737	5508007021	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.06387	-118.34429	NOT CHECKED FOR OSHPD3, NOT A STATE LICENSED BUILDING PER ENGINEER..  2 STORY ADDITION TO EXISTING 2- STORY BUILDING,  CONVERT (E) TAKE OUT RESTAURANT AND OFFICE TO (N) MEDICAL OFFICE  AND SHELL ONLY GENERAL OFFICE SEPARATE TENANTS.  FULL PLAN CHECK REQUIRED.  SITE IS IN A METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56175	12041-20000-26382	19755 W VANOWEN ST	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM			PC Approved	11/02/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56176	12041-10000-19925	12458 N LONGACRE AVE	91344	12	219B125   124	2601075060	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.29608	-118.53607	This is a two story SFD, 11.52KW pv system, with xfmr, regular inverter. (service & main panel board are existing)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56177	17041-10000-19827	2780 N LA CASTANA DR	90046	4	156B177   671	5570002029	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			Reviewed by Supervisor	06/20/2017 12:00:00 AM	ADDRESS	34.12103	-118.35768	Installation of new roof mounted solar PV system on existing single family dwelling with battery back up system.  New Solaredge SE 7600A inverter with 27 SolarCity Standard SC325 modules and 1 Tesla AC powerwall 5.8 kVA / 13 kWH battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56178	19041-20000-22153	15301 W VENTURA BLVD 2nd Floor	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.15411	-118.46654	Existing commercial corridor remodel.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56179	15041-10001-26538	633 W 5TH ST LEVEL 2	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM			PC Approved	04/07/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	04/07/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REMOVING LIGHTING FIXTURES. NOTE: PERMIT PULLED UNDER PCIS#15041-10000-26538(((PC FOR ENERGY. LOBBY ENTRY AREA, LEVEL 2. TOTAL  AREA 300SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56180	15041-10000-23071	2911 E 11TH ST	90023	14	120A221   178	5170025015	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	04/11/2016 12:00:00 AM		Issued	04/11/2016 12:00:00 AM	ADDRESS	34.02157	-118.21566	UPGRADE SERVICE TO 800A FOR FUTURE LOAD ADDITION. LOADS ARE EXISTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56181	16041-20000-17474	16417 W OTSEGO ST	91436	5	171B137   248	2260002008	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2016 12:00:00 AM			Reviewed by Supervisor	05/24/2016 12:00:00 AM	ADDRESS	34.16274	-118.49038	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (49) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56182	14041-10000-27638	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Medium voltage switchgear and new feeder replacement with same size and same location. total 1200 Amp equipment with 4160 volts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56183	13041-20000-34886	6309 N BEN AVE	91606	2	177B165    94	2334003058	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.18519	-118.39446	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56184	16041-10001-18796	2939 W LEEWARD AVE 1-80	90005	1	132B197   276	5077016017	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			10/03/2019 12:00:00 AM			PC Approved	10/17/2019 12:00:00 AM	ADDRESS	34.05886	-118.28782	Changes to an approved set of plans. All changes clouded under delta 7. Changes include adding a meter for the fire pump, and revising floor plans to reflect new fire pump meter. Note: Plan Check Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56185	18041-10001-18140	7919 S CROYDON AVE	90045	11	099B165   707	4107005032	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	33.96609	-118.39262	** expedited per applicantNew rooftop solar system on SFD, (32) modules with (32) power optimizers, (1) 7.6 kW inverter, (1) 13.5 kWh ESS, (1) 200A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56186	11041-10000-18428	2911 W 8TH ST	90005	1	132B197   424	5077018009	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			PC Approved	09/06/2011 12:00:00 AM	ADDRESS	34.05786	-118.28955	TI TO AN EXISTING OFFICE BUILDING.  PLAN CHECK IS FOR ENERGY, WITH EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56187	17041-20001-18042	19400-19408 W LONDELIUS ST	91324	12	195B117   145	2783027015	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM			PC Approved	11/13/2017 12:00:00 AM	ADDRESS	34.22976	-118.55588	11/13/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes include the addition of equipment and minor lighting revisions. All lighting changes have been reflected onto the Title 24 forms.*****Previous Work Description*****ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56188	19041-10000-29719	2003 S CORINTH AVE	90025	11	126B153   790	4261034002	R2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.0401	-118.44451	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56189	15041-20000-09756	16600 W SHERMAN WAY	91406	6	183B137    71	2225005010	(Q)CR-1VL, (Q)P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Issued	04/02/2015 12:00:00 AM	ADDRESS	34.20096	-118.495	Title 24 plan check only.  Total area = 4,470 sq. ft.T.I. to existing office space.  New lighting and recepticles.  New fixtures to be connected to existing lighting circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56190	18041-20000-09941	7600 N BALBOA BLVD 202	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. RETAIL . UNIT 202	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56191	12041-10000-26723	16450 W VENTURA BLVD	91436	5	168B137   385	2284002044	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.15731	-118.49192	Plan check for service upgrade from 240V to 480V. Gelson's Market. New 2000A service, 2000A panel, seven 150kVA transformers, and one 75kVA transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56192	12041-10000-05364	5358 W WILSHIRE BLVD	90036	4	132B181    18	5089002022	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Approved	03/14/2012 12:00:00 AM	ADDRESS	34.06203	-118.34566	T.I. to an existing restaurant.  New lighting, recptacles, and loads.  PLAN CHECK ONLY for Energy, All Emergency lighting is existing per applicant and not a part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56193	17041-20000-41830	821 W COEUR D'ALENE AVE	90291	11	108B149  1071	4237019008	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	PIN	33.99082321	-118.4532346	pv1install roof mounted pv system sized 4.5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56194	14041-20000-22620	5900 N LINDLEY AVE	91316	5	174B125    25	2159009010	R1-1	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.17729	-118.52709	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(15) TRINA SOLAR TSM-255 MODULES(15) SOLAR EDGE POWER OPTIMIZERS P300(1) SOLAR EDGE SE3800 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56195	18041-20000-26970	640 N LAS LOMAS AVE	90272	11	129B121   819	4414013009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.04692	-118.53922	pv1install roof mounted pv system sized 7.3KW AC interconnected with msp.(20) LG365Q1C-A5 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56196	15041-20000-01991	10914 N DARBY AVE	91326	12	210B125   700	2715004019	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.26864	-118.53368	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZED 5.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56197	10041-10000-15844	6120 N LANKERSHIM BLVD	91606	2	177B169   432	2338005008	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.01	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	10/08/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.18187	-118.38467	TENANT IMPROVEMENT FOR NEW DOLLAR TREE STORE.   PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56198	14041-20001-05985	8635 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Expired	07/05/2017 12:00:00 AM	ADDRESS	34.07373	-118.38073	THIS IS PLAN CHECK FOR CHANGES TO WEST TOWER SET OF PLANS. CHANGE IN ADDRESS AS WELL. THIS PERMIT REFLECTS WEST TOWER LOCATED AT 8635 W 3RD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56199	15041-10000-12346	621 S WESTERN AVE # G02	90005	10	135B193   955	5503031019	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM			PC Approved	04/24/2015 12:00:00 AM	ADDRESS	34.0628	-118.30928	Energy plan check for a retail T.I. located in # G02 of a commerical building;  scope includes installing new equipment, lighting and receptacle in a retail store of 690-SQ feet area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56200	10041-10001-03056	6750 W SUNSET BLVD	90028	13	147A185    92	5547021001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	09/02/2011 12:00:00 AM	ADDRESS	34.09769	-118.33815	CHANGE THE APPROVED PLAN. CHANGE THE OUTDOOR LIGHTS AND T24 CALC (OLTG-1C). ((((((((((NEW RESTAURANT- CHICKEN FILLET)))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56201	13041-20000-19113	18015 W RAYMER ST	91325	12	195B125   919	2787001061	R1-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.22761	-118.5257	PV1 TRANSFORMERLESS INVERTER. 33 PANELS AND 2 PANELS. 8.085 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56202	13041-20001-34372	6500 W SELMA AVE	90028	13	148-5A187 328	5547017001	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM			PC Approved	10/22/2014 12:00:00 AM	ADDRESS	34.09966	-118.33121	[[[[10/22/14  CHANGES TO APPROVED SET. DELTA 2 CHANGES ONLY. CHANGES TO INDOOR LIGHTING PLUS INCLUSION OF MEZZANINE IN T24.]]]]POWER AND ENERGY FOR LOWRISE HOTEL WITH 2000A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56203	18041-20000-44182	5150 W WILSHIRE BLVD lobby	90036	4	132B181    35	5507025021	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Issued	11/19/2018 12:00:00 AM	ADDRESS	34.06202	-118.3421	ti to an exisitng commercial building lobby only.  adding new lighting new controls to existing panels.   plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56204	18041-10000-27646	319 E WASHINGTON BLVD	90015	14	123A207   194	5127022015	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	07/13/2020 12:00:00 AM	ADDRESS	34.0299	-118.26173	PLAN CHECK FOR TITLE 24 ONLY FOR FOR TI - WAREHOUSE - TOTAL AFFECTED AREA = 2582 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56205	18041-10000-30324	3415 S SEPULVEDA BLVD Suite# 670	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.02055	-118.42347	TI TO EXISTING OFFICE IN SUITE #670, (1300 SF). T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-23165	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56206	12041-10000-07433	14006 W RIVERSIDE DR #0245	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Change of lighting and receptacles for an existing retail store.  Occupant load of  99 and load of 82A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56207	18041-20000-31017	3736 W CLAYTON AVE	90027	4	148-5A203 340	5430009014	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	02/01/2020 12:00:00 AM	ADDRESS	34.10041	-118.2756	Plan check for battery back up system, install 2 Tesla PowerWall 2.0(13.5kWh) battery to existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56208	16041-10000-05173	9301 N TAMPA AVE Space-39	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Energy plan check for a retail ( Space-39) T.I located in the Mall. Scope includes new lighting and receptacles with a total area of 5283-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56209	12041-20002-17445	18600 W DEVONSHIRE ST Sale-Office	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/01/2013 12:00:00 AM	ADDRESS	34.25704	-118.53922	changes to approved set of plans. fixture count remains. minor changes in arrangment of fixtures and area partitions. pc for changes of approved set. t24 energy only. New panels and circuits for the sales office building.  Plan checked for T-24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56210	13041-20000-22810	10342 N STAFFORD LANE	91311	12	204B113   101	2707015014	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.25863	-118.57747	pv1 single family dwelling. total system size 6kw using 17 modules. transformerless inverter. 2 strings. non standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56211	19041-20000-22614	16027 W MALDEN ST pv1	91343	12	192B141   127	2673003059	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.22576	-118.4818	pv1install roof mounted pv system sized 7.6KW AC interconnecte with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56212	11041-10002-11376	1902 E MARENGO ST	90033	14	132A223    33	5201016003	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM			PC Approved	01/09/2014 12:00:00 AM	ADDRESS	34.05756	-118.21009	SUPPLEMENTAL PLAN CHECK. DELTA 1 CHANGES ONLY. T24 CHANGES. MOVING PUMPS FROM PANEL HP2 TO HP1. 2 HAND DRYER CKTS ADDED TO HP2. FEW FUTURE CKTS ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56213	14041-20000-23817	13367 N CANYON RIDGE LANE	91344	12	225B133    24	2601016023	RS-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	10/08/2014 12:00:00 AM	ADDRESS	34.31414	-118.50412	PV1.  Install 6.000 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56214	19041-10000-49717	15105 W WEDDINGTON ST	91411	4	172-5A147 143	2250004063	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Issued	12/13/2019 12:00:00 AM	ADDRESS	34.16745	-118.46198	$0 Fee due to AB1414(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION WITH AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES  49 MODULES (PANASONIC 335 WATTS), 49 MICROINVERTERS (ENPHASE IQ7X MICROINVERTERS), 3 POWERWALLS, 2 PANELS OF 125 AMPS, AND 2 PANELS OF 200 AMPSSYSTEM SIZE: 16.415 KW DC; 15.435 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56215	15041-20001-08331	17823 W CHATSWORTH ST	91344	12	207B129   365	2712030017	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	34.26513	-118.52237	02/17/2016 Changes to an approved set of plans. Changes have been made to the lighting and power floor plans. All changes have been clouded and marked as Delta 2.*****Previous Work Description*****Plan check for power and  energy T.I. for restauruant and new service 400A. Total area: 3252 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56216	19041-10000-28776	1174 S LA BREA AVE S1	90019	10	132B181  1219	5084021016	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.054	-118.3433	PC for Methane mitigation system (Lever 4), 1 fire alarm panel, 1 power supply and 5 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56217	14041-20001-05479	6355 W BLANCHARD CANYON ROAD	91042	7	204A205    16	2569019053	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.25459	-118.27006	Fee for Expedite fee only.*****Roof mounted PV system with 8.25KWdc.*****Note: Permit include upgrade the service panel to 225A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56218	14041-20000-04440	567 S COMSTOCK AVE	90024	5	138B157    97	4359015017	RE20-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.07181	-118.42987	New story SFD with 600A service.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56219	15041-20000-13153	11050 W PENDLETON ST	91352	6	198B173    49	2408001904	[T][Q]M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.2392	-118.37196	Plan check for Title 24 only. Project scope is the installation of outdoor canopy lighting and power. Total outdoor lighting area = 1,205 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56220	14041-20002-31042	4260 N EAGLE ROCK BLVD 1-56	90041	1	156A219   115	5474022023	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Apartment			05/14/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	34.12246	-118.22336	CHANGE TO APPROVED SET OF PLANS. CORRECTED SERVICE SIZE. CHANGES INCLUDED MODIFY CIRCUIT WIRING AND ADDED MORE DETAILED NOTES. ALL CHANGES CLOUDED DELTA 1 REVISIONS. ROOF PLAN RESTAMP FOR CHANGE IN LAYOUT. THIS IS PLAN CHECK ONLY. NO PERMIT ISSUED. PERMIT UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56221	18041-20000-17752	20444 W VIA CELLINI	91326	12	219B109   258	2701055008	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.29443	-118.58072	Plan check for PV roof mounted system, system size: 10.4kW with 34 modules and 2 inverters(5.2kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56222	17041-30000-45500	2112 S BARRINGTON AVE Bldg A	90025	11	123B149   250	4260008012	C2-1, R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.03531	-118.44854	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,024 sq. ft.Note: Building application has been generated under 17016-30000-13011	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56223	18041-20000-13349	1001 S OLIVE ST # 120	90015	14	127-5A209 222	5139009016	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.04228	-118.25988	Plan check for first time tenant Verizon in the mix-use building 1st floor STE 120. Total area: 1680 sq ft. B#18016-20000-11216	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56224	19041-20000-25115	6080 W CENTER DR 11th flr-restroom	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56225	10041-10000-01181	5333 W ZOO DR Elephant-Barn	90027	4	162B197     1	5593002907	OS-1XL	Central	Hollywood	Greater Griffith Park	YES	1882.00	Electrical	Electrical	Public Safety Only			01/22/2010 12:00:00 AM	01/22/2010 12:00:00 AM		Permit Finaled	03/11/2011 12:00:00 AM	ADDRESS	34.14867	-118.28623	Plan check for new installation of fire alarm system in the Elephant Barn & Cambodian Bldg. of the LA ZOO. This application for permit in the Elephant Barn. Cambodian Bldg under permit #10041-10000-01184	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56226	12041-10000-28805	15551 N SORBONNE ST	91342	7	228B141   197	2603020010	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.32177	-118.47486	9.36 kw Roof mounted PV for a single family. (PV1)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56227	17041-20003-19012	817 N VINE ST Bldg A	90038	13	141B185   173	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.0858	-118.32679	Change of lighting control package from nLight to Lutron system.  Corresponding updates to lighting plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56228	18041-10001-05183	1177 S WEST BLVD	90019	10	129B185   241	5083012010	R3-1	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	34.05248	-118.33238	Change to approved set by modifying the single line and floor layout.  New service upgrade is under a separated permit.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.5KWdc / 5.0KWac. (20)MODULES-SOLARCITY STANDARD SC325(20)OPTIMIZIERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE5000H-US000SNU2)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56229	19041-10000-11243	3329 E UNION PACIFIC AVE	90023	14	117A223    12	5190031004	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Issued	03/28/2019 12:00:00 AM	ADDRESS	34.01657	-118.2079	PLAN CHECK FOR NEW FIRE ALARM SYSTEM  IN A 2 STORIES COMM. BUILDING. TOTAL DEVICE COUNT 43 WITH 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56230	19041-20000-20027	333 S HOPE ST 25th flr	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	ti to an existing commercial building (bathrooms).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56231	17041-20000-22782	20709 W MARTHA ST	91367	3	174B109   386	2151035018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.1728	-118.58416	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.75 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56232	16041-20000-17051	1218 S FLOWER ST Tower 1	90015	14	126A207    34	5138026030	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.04096	-118.26567	Plan check for power and energy. Project scope is a new Mixed use 31 and 39 story High-rise commercial building  (two towers with adjoining underground parking lot). Total lighting area = 790,539 sq. ft.This application is for Tower 1, equipment fees have been charged under application number 16041-20000-12275Refference 2 Building Applicantion #: 14010-100000-01784 & 14010-100000-01777	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56233	14041-20000-24743	11727 W FOLKSTONE LANE	90077	5	153B141   128	4377041051	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM			Corrections Issued	09/10/2014 12:00:00 AM	ADDRESS	34.11523	-118.47349	New 4400W Roof Mounted PV System on a Single Family House.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56234	18041-10000-29189	1005 N GAFFEY ST	90731	15	021B197   522	7447022901	CM-2D-CPIO	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.75317	-118.29303	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56235	17041-20000-32533	12431 W ROCHESTER AVE 1-50	90025	11	126B145   898	4267034020	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			09/12/2017 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	12/04/2020 12:00:00 AM	ADDRESS	34.03904	-118.46767	Plan check for power and energy. New 5-story, 50-unit apartment building over 2 levels of subterranean garage. 6 typical units. 1600A 120/208V 3ph 4w service. T24 area - 31,711sqft. Fire alarm variance on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56236	17041-10000-35319	4300 S LINCOLN BLVD	90292	11	105B153    81	4212004011	[Q]M1-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	09/10/2021 12:00:00 AM	ADDRESS	33.98556	-118.443	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 12050 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56237	19041-10000-13733	2337 W RIDGEVIEW AVE	90041	14	159A221    89	5685027005	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	09/20/2021 12:00:00 AM		Permit Finaled	09/24/2021 12:00:00 AM	ADDRESS	34.13131	-118.21785	BLDG 5 OF 5Provide new 600 A service for entire property feeding new sub meters to each house. Each house is a three story single family dwelling, Each house is fed 200 A. Note please assign to the same plan checker, 5 different applications under the same project.  All the fees will be listed under the application for  building 5, this building is adjacent to the main service. BLD# for BLD 5: 19010-30000-01525Electrical App # for Bld 1: 19041-10000-13725Electrical App # for Bld 2: 19041-10000-13726Electrical App # for Bld 3: 19041-10000-13728Electrical App # for Bld 4: 19041-10000-13732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56238	12041-10000-07783	20201 W WELLS DR	91364	3	171B113   535	2166038023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.16103	-118.57257	New 13.44kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56239	13041-20000-13856	833 N STRADELLA ROAD	90077	5	141B149    86	4369023012	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	34.08434	-118.45293	Plan check for new SFD. NOT methane hazard. 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56240	16041-20000-23804	3227 W PERLITA AVE	90039	13	153B209   716	5436011026	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.11425	-118.25258	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 2.5KW, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56241	13041-10000-35051	726 E 12TH ST #103	90021	14	123A211    22	5132012060	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.03314	-118.25248	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 936 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56242	14041-20001-04506	14723 W ADDISON ST	91403	4	171A149   295	2263031052	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.16135	-118.45378	changes to approved set of plan. change in conduit size and conductor size.%0 plan check fee due to senate bill 1222 from 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56243	15041-20000-32363	15910 W VENTURA BLVD 18TH FLOOR	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.15561	-118.47969	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOM. 18TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56244	18041-10000-46548	1925 S CENTURY PARK EAST 1st Flr	90067	5	132B161    30	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	1ST FLOOR.  REMODEL OF CORRIDOR & LOBBY AREA.  INSTALING NEW LIGHTS, T-24 ONLY. 1,115 SQR FT. BLDG PERMIT: 18016-10000-36517	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56245	14041-20000-19845	5192 N KNOLLWOOD WAY	91364	3	171B097  1774	2075039001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.16498	-118.61972	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(17) TRINA SOLAR TSM-255 MODULES WITH OPTIMIZERS P300 SOLAREDGE(1) SOLAREDGE SE3800 A-US-ZB-U INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56246	17041-20000-17575	19140 W CHARLES ST	91356	3	168B121   221	2176031007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM	07/03/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.15742	-118.55044	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 11.6 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56247	13041-20000-04153	15725 W PARTHENIA ST	91343	12	195B141   558	2672011043	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	06/19/2013 12:00:00 AM	ADDRESS	34.22848	-118.47482	energy plan check office remodel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56248	19041-20000-51976	2073 N REDCLIFF ST	90039	4	147A205   210	5431015003	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.09739	-118.26996	Plan check for PV roof mounted system, PV system size: 11.15KW DC, 9.92KW AC with 31 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56249	12041-20000-24750	2222 W OCEAN VIEW AVE #210	90057	1	135A203   382	5154033021	C2-2, PB-2	Central	Westlake			2088.01	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			Corrections Issued	10/16/2012 12:00:00 AM	ADDRESS	34.06274	-118.27489	T.I. to a laboratory Suite 210 in an existing two-story building.  Convert a conference room to individual offices, lighting, receptacles and new A/C on the roof.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56250	18041-20000-35669	11415 W VENICE BLVD #1-13	90066	11	114B157   422	4234008025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Apartment			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.01048	-118.42205	Renovations to (E) 13-unit apartment building.  400A 240/120V 1ph-3w service upgrade.  Plan check for energy only for common areas.  Building permit under 18016-30000-27500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56251	16041-10000-33217	2179 E CENTURY BLVD 101-208	90002	15	093A217   273	6049019***	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	33.9467	-118.23369	PC for power only for a mixed use 3-story 8-unit apartment C1 building with commercial office space and parking garage (Bldg 8 of 8). Scope includes a new 600A 120/208V 3 phase 4 wire service/distribution board. One plan is submitted for multiple apartment buildings. B#16010-10000-02993	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56252	15041-20001-42326	6650 N CAMELLIA AVE	91606	2	180B169   375	2320022003	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.19181	-118.38219	Expedite FeePV1, rooftop installation 12kW AC system.(38) SPR-327NE-WHT-D(2) SB6000TL-US*Derate Main Breaker from 200A to 150A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56253	19041-10000-32804	20835 W TIARA ST	91367	3	174B109    64	2149013031	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.17651	-118.58588	$0 fee due to AB1414[EPLAN] PLAN CHECK FOR ROOF MOUTED 11KVA SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(SOLIS-1P6K-4G-US, SOLIS 1P5K-4G-US) AND 45 MUDULES(HANWHA QCELLS BLK-315) USING RAPID SHUTDOWN DEVICESPanel upgrade to be permitted separately	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56254	12041-20000-06895	127 S SAN VICENTE BLVD Bulletin-153 TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 1153  TI  plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56255	17041-10000-23617	3361 N ANDRITA ST LOT 8	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 8 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05790	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56256	12041-10000-30968	1038 E VERNON AVE	90011	9	112-5A209  62	5108028008	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.00369	-118.25748	CHANGE OF USE FROM (E) RETAIL TO (N) LAUNDROMAT.  NO CHANGE IN PARKING.PLAN CHECK IS FOR TI AND REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56257	13041-20000-23948	8401 N VAN NUYS BLVD #19	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.22308	-118.44896	Change to lighting in an existing retail space at the Panorama Mall, space 19.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56258	14041-20000-18937	11821 N ANDASOL AVE	91344	12	216B129   353	2601041044	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.28559	-118.51491	5.8KW PV1 roof-mounted system with (1) Soleredge SE6000A -US inverter, (20) Silevo Triex U290 Solar modules and (20) Solaredge P400 Optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56259	16041-10000-41226	14061 W ROSCOE BLVD	91402	6	192B153   770	2638037017	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.22179	-118.43948	PC for title 24, outdoor lighting. Remove HID fixtures and replace with new LED fixutures. Totalsqft = 23713	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56260	15041-20001-39126	23212 W SYLVAN ST	91367	3	177B093   166	2035022031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.18443	-118.63204	EXPEDITE PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.0KWac. (50) MODULES-KYOCERA #KU2656ZPA(2) INVERTER-ABB PVI-5000 & ABB PVI-6000(1) 125A SUBPANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56261	17041-10000-31596	10250 W SANTA MONICA BLVD Kiosk 9191	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Issued	09/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for power and energy on a core and shell for future tenant on Kiosk 9191. Install one panel and its circuitry.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56262	19041-10000-09184	19191 S VERMONT AVE ste. 250	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	Design build: Energy plan check for an office T.I located in suite 250, common corridors, restrooms and elevator lobby of a high rise building. Scope inlcudes new lighting and equipment with a total area of 16330-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56263	17041-10000-25660	14918 W VENTURA BLVD	91403	4	166-5A149  29	2276004005	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.15229	-118.45802	TITLE 24 PLAN CHECK TO REPLACE EXISTING (6) FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA = 11100 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56264	19041-20000-06622	10001 W VENICE BLVD	90034	5	120B165  1150	4313006041	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	04/02/2021 12:00:00 AM	ADDRESS	34.02296	-118.40001	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING APARTMENT BUILDING. SYSTEM SIZE IS 127.75KW DC/116.73 KW AC CEC. SCOPE OF WORK INCLUDES (350) CHINT SOLARAND (4) SE33.3KUS INVERTERS, A 200 LOAD CANTER, AND A 225KVA TRANSFORMER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56265	14041-10000-03801	1601 S SOTO ST	90023	14	120A221   205	5169014003	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM			Corrections Issued	02/11/2014 12:00:00 AM	ADDRESS	34.02091	-118.2204	"PLANCHECK FOR T24 ENERGY.CONVERT 1630 EXISTING GROUND FLOOR AUTO SPRAY PAINTING AREA TO OFFICES AND ADD  NEW OFFICE MEZZANINE ON TOP.  2762 SQFT, EMERGENCY LIGHTING.""COMPLY WITH DEPARTMENT ORDER effective date 11/08/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56266	13041-20000-26333	16133 W VENTURA BLVD	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Issued	09/23/2013 12:00:00 AM	ADDRESS	34.15675	-118.4847	Change to lighting and loads to an existing office building.  Load is less than 400 amps.  High rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56267	15041-20001-04509	3743 S MIDVALE AVE	90034	5	117B161   645	4252025007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			11/23/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.01737	-118.41181	11/23/15Changes to an approve set. Changes made under cloud/bubble. Scope includes adding two new panels and branch circuits.  Loads for panel 'hp' is distributed to the two new panels to comply with disaggregation of the loads (hvac/plumbing/lighting). permit under pcis#15041-20000-04509((((PLANCHECK FOR POWER AND ENERGY FOR NEW APARTMENT BUILDING . FIFTEEEN UNITS. 18 PARKING SPACES IN SUBTERRANEAN GARAGE 4 STORIES W/ ROOF DECK. FIRE ALARM VARIANCE HAS BEEN SUBMITTED.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56268	11041-10001-07647	6355 N DE SOTO AVE Bldg 2	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	02/29/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.18639	-118.58869	revised permitted set of plans as follows: change feeders to residential panels  from cu to al and added 1ea 10hp trash compactor and 1 ea panel board( no loads add4ed)New 4 story 116 unit apartment building.  This application was generated to create a separate plan check and permit application for building 2.  The plan check submittal fee was adjusted to a lower value to account for building 2 plan check fees paid on  application 10041-10000-24305.The fee for permit is indicated under the inspection fee period for this application.The fire alarm plan and permit for building 2 was issued on application # 11041-10000-04061.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56269	15041-10000-31911	435 W 8TH ST	90014	14	127-5A209  30	5144013027	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.04517	-118.25662	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 1736	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56270	15041-20001-21955	7962 W OCEANUS DR	90046	4	153B173   906	5569025024	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2015 12:00:00 AM			PC Approved	07/18/2015 12:00:00 AM	ADDRESS	34.11231	-118.36825	Expedite per applicant request{{{{Plan check for PV roof mounted system. System size: 11.0kW with 42 modules and 42 microinveters.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56271	13041-20000-22847	724 W ACADEMY ROAD	90012	1	139-5A217  22	5415024032	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural	YES	2060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.0777	-118.23346	pv1 single family dwelling. total system size 3kw using 11 modules. transformerless inverter. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56272	16041-20000-09890	220 N BRISTOL AVE	90049	11	132B137   230	4405019019	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM			Reviewed by Supervisor	04/11/2016 12:00:00 AM	ADDRESS	34.05934	-118.48845	Plan check for power only. NEW 2-STORY SINGLE FAMILY DWELLING W/BASEMENT. 1600A service. 22,715sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56273	14041-10000-24969	11730 W SHELDON ST	91352	6	198B169    17	2538004025	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.24294	-118.38846	Plan check for title 24 energy. Remove HID light fixtures and replace with new fluoresent fixtures. 23200 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56274	18041-10000-38062	4201 W WILSHIRE BLVD #203	90010	4	135B189   972	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.06189	-118.31911	PLAN CHECK FOR ENERGY ONLY FOR - TENANT IMPROVEMENT INCLUDING NON-BEARING WALL MODIFICATION, FINISHES, AND CEILING. - TOTAL AFFECTED AREA = 3665 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56275	18041-20000-37687	10635 W SANTA MONICA BLVD ste 100	90025	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.05353	-118.43031	ti to an existing commercial building (dental office).   plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56276	14041-10000-03876	1319 S OGDEN DR	90019	10	129B177   249	5086015009	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Expired	04/27/2016 12:00:00 AM	ADDRESS	34.05248	-118.36406	PV1, Install 45 kW DC roof-mounted solar array on a two-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 5000A-US. (18) Modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56277	13041-20000-12135	521 E VENEZIA AVE	90291	11	108B145  1757	4237003011	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM			PC Approved	05/09/2013 12:00:00 AM	ADDRESS	33.9891	-118.45995	Load is less than 400 amps.  Plan check for energy and emergency lighting only.  Existing Bicycle construction.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56278	12041-20001-08833	6600 N TOPANGA CANYON BLVD #2008	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Changes to approved set of plans. Change from unit equipment to inverter in dining area. T. I. - New restaurant in exist. Westfield Topanga Mall	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56279	14041-10000-04723	1851 W SAN FERNANDO ROAD	90065	1	148-5A215 107	5442004011	[Q]MR1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM			Corrections Issued	02/20/2014 12:00:00 AM	ADDRESS	34.10033	-118.23528	TI IN A COMMERCIAL KITCHEN. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56280	14041-10000-02995	380 WORLD WAY SUITE 0041	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF EXISTING OFFICE SPACE IN SUITE 0041 OF TOM BRADLEY INTERNATIONAL TERMINAL. 740 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56281	14041-10000-31084	10210 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.25591	-118.57964	Plan check for Title 24 only. 1-story office building. Indoor lighting area = 5850 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56282	19041-20001-06181	321 E ROSE AVE	90291	11	111B141   549	4286002014	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			02/20/2019 12:00:00 AM			PC Approved	04/09/2019 12:00:00 AM	ADDRESS	33.997	-118.4764	Expedited plan check fee.PV2.  Install 13.44 kW roof mounted grid tied PV system.  (42) modules with (4) 3.8 kW rated string inverters and one string on microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56283	18041-20000-43637	451 N BRISTOL AVE	90049	11	135B137   541	4406006013	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.06377	-118.48889	pv1install roof mounted pv system sized 10.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56284	14041-10000-00335	1820 E INDUSTRIAL ST	90021	14	124-5A2171372	5164021121	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.03563	-118.23389	PLAN CHECK FOR POWER. UGRADE OF SERVICE AND DISTRIBUTION BOARD TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56285	11041-20001-26258	4141 N WHITSETT AVE	91604	2	165B161   914	2375018020	A1-1XL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.14613	-118.40546	outdoor tennis courts exempt from title 24 calculation only required mandatory control	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56286	15041-20000-27088	12629 N AMBOY AVE	91342	7	219B145    51	2604040012	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Expired	09/18/2017 12:00:00 AM	ADDRESS	34.30064	-118.47216	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel.(10) Canadian CS6P-255P Modules(5) Canadian CS6P-235PX Modules(1) Solard edge SE3800A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56287	09041-20001-22685	8126 W MELROSE AVE	90048	5	141B173   460	5528010001	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM			PC Approved	03/16/2010 12:00:00 AM	PIN	34.08347203	-118.36676186	Supplimental to previously approved plan. The change has been doing outdoor lighting and re-arranging interior lighting. INTERIOR REMODEL & TENANT IMPROVEMENTS.  CHANGE OF USE FROM RETAIL TO RETAIL & BEAUTY SALON. TITLE 24 AND EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56288	11041-10000-22635	11237 W LUCERNE AVE	90230	11	111B165   233	4215031014	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	33.99953	-118.40319	New 6.4 KW, rooftop, Photovoltaic system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56289	17041-20000-43520	5054 S VERMONT AVE	90037	9	111B197  1346	5018018019	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	33.99673	-118.29133	Plan check for power and energy. TI/Change of use of portion of building from child care facility to office, new 1st and 2nd floor addition to (E) office. New 600A 120/240V 3ph 4w service. T24 area - 11,022sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56290	13041-10000-20284	1601 E MARTIN LUTHER KING, JR BLVD	90011	9	115-5A213 170	5117009030	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Expired	08/25/2015 12:00:00 AM	ADDRESS	34.01059	-118.24645	PV1. INSTALLING ROOF MOUNTED SOLAR ARRAY, INTERCONNECTED WITH MAIN PANEL. SYSTEM SIZE: 7.35 kW. NO COMBINER BOX. 3 CONDUITS TERMINATING IN THE INVERTER. 2 STORIES. INVERTER HAS 3POLE INTEGRATED DISCONNECT. TRANSFORMER TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56291	15041-20000-18701	905 S ARDMORE AVE 1-12	90006	10	132B193   892	5093023027	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.20	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.05563	-118.30221	New 12 unit apartment building. Plan check for power and energy. Adding new 800A service. Adding new lighting including emergency. Total sqft. 8,910.Note: 2008 Title 24 Compliance Forms are being used. Building application was filed on 03/03/2014 under application number 14010-30000-00558	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56292	16041-10000-10027	6501 S 2ND AVE	90043	8	105B189  1611	4007026029	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	33.98093	-118.31979	PV1 roof mounted system with (9) module and (1) inverter interconnecting through the main service	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56293	15041-10000-17107	13728 N SIMSHAW AVE	91342	7	228B161   383	2511033012	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.32166	-118.41571	PV1, ROOF MOUNTED SYSTEM. 16 MODULES AND 16 MICROINVERTERS, ENPHASE M250. TOTAL 3.9 KW(16) SOLAR WORLD 285 MOMO MODULES (16) ENPHASE M250-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56294	18041-20000-06404	1017 N CROFT AVE #1-16	90069	5	144B173   142	5529007023	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	07/17/2023 12:00:00 AM	ADDRESS	34.08945	-118.37446	Plan check for power and energy for new 4 story 16 unit apartment building with basement garage - scope includes 800A 120/208V. Total affected area = 18,311 sq. ft.BUILDING PERMIT # 16010-1000-06280	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56295	13041-20000-35489	1423 N MCCOLLUM ST	90026	13	142-5A205 394	5424016023	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.08371	-118.26743	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING 10 MODULES TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56296	14041-20001-02117	23255 W ARMINTA ST PV1	91304	12	189B093   419	2020024004	RE11-1	South Valley		West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.21337	-118.63435	((EXPEDITE FEES))))New ungrounded PV System for an existing single family dwelling with two inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56297	11041-20000-14797	127 S SAN VICENTE BLVD Bulletin-72TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta # 72 TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56298	16041-10003-23960	2409 N GRIFFITH PARK BLVD	90039	4	148-5A205  38	5432003004	RD2-1VL, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Apartment			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.10303	-118.27254	"DELTA 2 CHANGES TO APPROVED PLANS FOR ADDING ""EXIT"" SIGNS.DELTA 3 CHANGES FOR RE-LOCATION OF EQUIPMENT IN THE ELECTRICAL ROOM. **INSTALLATION OF UNPROTECTED CONDUCTORS TO THE OTHER SIDE OF ELECTRIC ROOM, SUBJECT TO FIELD INSPECTION.**<<<PC FOR POWER AND ENERGY. PROPOSED 3 STORY, 13 UNITS,  RESIDENTIAL APARTMENT BUILDING OVER SEMI SUBTERRANEAN PARKING.  SERVICE SIZE 1200 A. 4 TYPICAL UNITS.B # 16010-10000-02240>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56299	19041-10000-22425	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	33.97954	-118.42015	PLAN CHECK FOR A MEDICAL OFFICE TI (KAISER PERMANENTE). SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROL. NO SURGICAL OPERATIONS. TOTAL AFFECTED AREA IS 39,059 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56300	19041-10000-24795	7007 N LANKERSHIM BLVD	91605	2	183B169   250	2321007037	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Closed	12/29/2022 12:00:00 AM	ADDRESS	34.19774	-118.38805	Plan check for removing HID fixtures and replace with new LED Fixture for outdoor area with a total lighting fixture of 9100-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56301	18041-20001-02146	17116 W LABRADOR ST	91325	12	201B133   206	2692012023	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	34.24967	-118.50574	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.025 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56302	18041-20000-33399	7355 N VARNA AVE	91605	2	186B157   379	2328027006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	08/19/2022 12:00:00 AM	ADDRESS	34.20459	-118.42485	Plan check for power and energy. Project site is a 1-story warehouse. Work includes a 600 Amp service and a total lighting area of 11,400 sq. ft.Note: Building permit has been issued under 17010-20000-05184	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56303	15041-20000-28664	221 N FIGUEROA ST 7th floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM			PC Approved	08/31/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	TI to existing commercial building (offices). Plan check for energy only. Total sqft. 20,248.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56304	18041-10000-00969	10435 W SANTA MONICA BLVD	90025	5	132B157   686	4326032031	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	34.05686	-118.42548	PC for FA system in two story commercial building. Installing 1 FACP, 1 annunciator, 2 RPS panel and 53 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56305	14041-20000-20042	7921 N OSO AVE	91306	3	189B113   674	2107025057	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Expired	08/29/2016 12:00:00 AM	ADDRESS	34.21442	-118.57554	Standard plan: 7.6KW PV1 roof-mounted system with (2) Solaredge SE3800A transformerless inverters, (33)  Trina Solar TSM-255 modules and Solaredge P300 power optimizers; connecting through a 125Amp load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56306	16041-20000-14537	9199 W THRASHER AVE	90069	4	147B169   916	5560006021	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM			PC Info Complete	04/26/2016 12:00:00 AM	ADDRESS	34.09552	-118.39013	Plan check for power only. New 130kW natural gas generator for SFD, connect to new ATS. Remove link between bus and main disconnect in MSB. Feed ATS from load side of MSB main breaker, then re-feed MSB bus from ATS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56307	19041-20000-44238	4971 S CENTINELA AVE	90066	11	105B161   144	4221023034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	12/07/2021 12:00:00 AM	ADDRESS	33.98726	-118.4165	Plan check for new fire alarm system, Fire alarm devices: 86 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56308	15041-20000-35545	117 E 51ST ST	90011	9	111A205   326	5109004044	RD2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	33.99661	-118.27328	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (2) inverters, (16) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56309	18041-20000-07137	12106 N BELLANDO CT	91344	12	219B125    88	2601073017	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.29366	-118.52559	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 18.9KVA (11.4KVA NEW INVERTER (SE-11400-US), 7.5KVA EXISTING INVERTER) - NEW SYSTEM 35 PANELS WITH P400 OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56310	18041-20000-30959	4673-4683 W HOLLYWOOD BLVD	90027	4	147B197   304	5542001004	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	09/17/2019 12:00:00 AM		Issued	09/17/2019 12:00:00 AM	ADDRESS	34.10096	-118.29101	1200A 208Y/120V service upgrade for multi-tenant commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56311	13041-20000-00562	3936 N TOLAND WAY PV-1	90065	14	154-5A217  68	5460027004	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.11896	-118.22842	PV-1. Transformerless inverter. Gaytan Residence. 2.16kw.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56312	17041-10000-12087	11300 W OLYMPIC BLVD STE 920	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	03/31/2022 12:00:00 AM	ADDRESS	34.03792	-118.44134	Energy plan check for an office T.I. Total area is 395 SQ ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56313	16041-10001-07551	5317 E YORK BLVD	90042	14	156A227   382	5478003014	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM			Corrections Issued	06/16/2016 12:00:00 AM	ADDRESS	34.12031	-118.19996	RECHECKING FOR LOST SET OF PLANS. $0 PLAN CHECK FEE DUE TO CLERICAL ERROR. OK FOR PAYMENT. THIS APPLICATION IS PLAN CHECK ONLY. PERMIT SHALL BE ISSUED UNDER MASTER APPLICATION.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56314	13041-10000-26831	12746 W JEFFERSON BLVD #1160	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	PLAN CHECK FOR POWER TO CHASE BANK SUITE #1160 IN BUILDING #1. LANDLORD FEEDER TO TENANT WHICH INCLUDES EQUIPMENT, PANELS, AND CIRCUITS. CHASE BANK TI UNDER #13041-10000-20412.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56315	14041-10000-12054	210 W 7TH ST #4	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			Corrections Issued	05/06/2014 12:00:00 AM	ADDRESS	34.04461	-118.25275	T24 FOR SIGN INSTALLING FOR CVS PHARMACY. #2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56316	16041-10000-17155	1840 S CENTURY PARK EAST 18TH FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	12/10/2016 12:00:00 AM	ADDRESS	34.06188	-118.41473	T-24, PC FOR ENERGY ONLY. INTERIOR FULL FLOOR TENANT IMPROVEMENT FOR AN EXISTING HIGH RISE BUILDING ON THE 18TH FLOOR OFFICE SPACE. TOTAL AFFECTED AREA IS 14846 SQ FT. B # 16016-10000-10294	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56317	19041-20000-37663	11116 N WOODLEY AVE	91344	12	210B141   495	2666019003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.27241	-118.48451	PV1. INSTALL 11.34 KW DC SOLAR SYSTEM WITH (36) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE10000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56318	16041-10000-35116	6421 W SELMA AVE	90028	13	148-5A187 303	5546007023	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Closed	01/04/2017 12:00:00 AM	ADDRESS	34.09988	-118.33029	FA installation to new restaurant. (1) FA panel, (107) FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56319	15041-20001-27518	7195 W FORMOSA FUSION CT	90046	5	141B181  1711	5525003036	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.08566	-118.3459	[[CHANGES TO APPROVED SET. ADDING ADDITIONAL 4 MODULES, AND 4 MICROINVERTERS TO THE EXISTING SYSTEM]]]PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56320	15041-20000-37562	10443 N LARWIN AVE Unit 2	91311	12	207B101   276	2723012***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.2601	-118.61384	Plan check for a PV2 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (20) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56321	19041-10000-08681	5151 W PICO BLVD	90019	10	129B181   916	5070009039	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.04828	-118.35054	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56322	17041-10000-19297	2144 W COLORADO BLVD	90041	14	162A223   132	5686003010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.13893	-118.21341	FIRST TIME TI. PC FOR POWER AND ENERGY FOR SMALL CELL PHONE STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56323	15041-10000-30985	816 S SANTA FE AVE	90021	14	123A217    45	5166003013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.03293	-118.22982	PC FOR ENERGY & POWER. CHANGE OF  USE TO (CHOCOLATE FACTORY)WHOLE SALE INDUSTRIAL. TOTAL AREA 4500 SQ PER APPLICANT (PLANCHECKER TO VERIFY THAAT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56324	18041-20000-42779	12549 W MARTHA ST pv1	91607	2	174B161   336	2341016030	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Issued	11/07/2018 12:00:00 AM	ADDRESS	34.17321	-118.40711	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.  (1)Battery back up 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56325	14041-10000-22201	14626 W RAYMER ST	91405	6	189B149   548	2210030017	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			Verifications in Progress	11/18/2014 12:00:00 AM	ADDRESS	34.21194	-118.45167	PC FOR ENERGY AND POWER FOR A  new commercial kitchen within adult cabaret. TOTAL AREA 550 SQ FT. (MEHDI)B# APPLICATION 14016-10000-16328 ON 08/15/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56326	19041-10000-37395	3650 N VERDUGO ROAD	90065	1	154-5A217 234	5460004900	OS-1XL	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.11661	-118.23319	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56327	17041-20000-40024	1039 N GALLOWAY ST	90272	11	129B129   569	4423013020	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Expired	09/28/2023 12:00:00 AM	ADDRESS	34.04841	-118.52148	Installation of a 15.5 kWh energy storage system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56328	14041-10001-00401	5107 W HAROLD WAY	90027	13	148-5A195 238	5544013008	RD1.5-1XL	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.09947	-118.30083	Supplemental to changes to approved set of plans - Changes under delta 3 only - scope only includes upsizing feeders and changing all unit feeders to aluminum only. See sheet E-1 for changes NEW 7 UNIT APARTMENT BUILDING. SERVICE SIZE 600A. plan check in accordance to 2008 NEC due to building submittal	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56329	19041-10000-09782	1515 W 190TH ST 4th	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	T-24 PLAN CHECK FOR A TI IN AN OFFICE BUILDING (HIGH RISE). SCOPE INCLUDES NEW LIGHTING IN COMMON AREA, LOBBY AND RESTROOMS USING EXISTING CIRCUITS.  TOTAL AFFECTED AREA IS 3265 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56330	19041-20000-40198	9768 N CEDROS AVE	91402	6	201B149   894	2650019067	(Q)RD2-1, (Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.24783	-118.4514	PV1. INSTALL 3.02 KW DC PV SYSTEM WITH (9) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56331	19041-20002-04734	687 S HOBART BLVD Unit D	90005	10	132B193   184	5093006035	(T)(Q)C2-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.0605	-118.30557	Plan check for power only for first time tenant Energy plan check has been done under application number 19041-20000-04734B# 18016-20000-37076	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56332	19041-10000-17595	8305 S GRAMERCY PL	90047	8	099B189   825	6035019011	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.96321	-118.3135	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56333	10041-10000-14540	122 S ROBERTSON BLVD 204	90048	5	138B169   422	4334005005	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM			PC Info Complete	07/28/2010 12:00:00 AM	ADDRESS	34.0746	-118.3836	T24 only for tenant space suite 204.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56334	14041-10000-20945	900 N BROADWAY	90012	1	135A215   235	5414013900	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	PIN	34.06407564	-118.23656378	PC FOR METHANE GAS DETECTION SYSTEM.  24 CONTROL DEVICES AND 1 PANEL AND 1 FIRE ALARM DEVICE,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56335	18041-20000-21368	11361 W NATIONAL BLVD	90064	11	120B153   448	4258016001	C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.02569	-118.43304	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56336	16041-20000-41984	16836 W SHERMAN WAY	91406	6	183B133   124	2225018012	R3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			12/01/2016 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.20089	-118.50004	(N) 18-UNIT 3-STORY TYPE V-A  APARTMENT OVER 1-STORY TYPE 1-A GARAGE.  1200A 120V/208Y 3PH-4W SERVICE.  PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT FILED UNDER 16010-20000-00883.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56337	17041-10000-39203	1423 E 15TH ST	90021	14	121-5A213 354	5130012013	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	04/06/2021 12:00:00 AM	ADDRESS	34.02519	-118.24453	PC for power and energy for two story office/warehouse building. Installing new 600A service and service panel, two subpanels, equipment, receptacles and lights. Building 14010-10000-02790	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56338	18041-10000-39847	304 S BROADWAY #430	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR TI IN A COMMERCIAL OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTICALS. TOTAL EFFECTED AREA IS 1175SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56339	15041-10000-24890	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	33.96577	-118.42406	ON THE LMU CAMPUE, INSTALLING MV 225KVA OIL-FILLED TRANSFORMER, A MV SWITCH ON THE PRIMARY SIDE AND A 800A DISTRIBUTION BOARD ON THE SECONDARY SIDEALL LOADS ARE EXISTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56340	14041-20000-34337	19020 W DEVONPORT LANE	91356	3	162B121    15	2177040016	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	34.14184	-118.54799	$0 permit fee due to senate bill 1222 from 2012PV1. INSTALLING ROOF MOUNTED. 18.5 AC KW SYSTEM SIZE. (64) SUNPOWER SPR-E20-327(1) SMA SB8000-US-22(1) SMA SB70000-US-22(1) SMA SB3000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56341	18041-20000-01375	2516 E 1ST ST	90033	14	127-5A223 275	5180006004	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	01/11/2019 12:00:00 AM		Issued	01/11/2019 12:00:00 AM	ADDRESS	34.04278	-118.20817	Change of use from retail to coin-op laundry.  Service upgrade to 600A 240/120V 3 phase.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56342	13041-10000-26851	1207 S VERMONT AVE	90006	1	129B197   797	5078028004	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			12/10/2013 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.04886	-118.29184	"plan check for power and energy to an Rehabilitation of (E) 13-stories apartment building.  12 floors, 9 units per floor. No change of use. 39 (E) panels to be replaced; charges will be based off new panels (not ckts) . existing 3000A, 208/120v 3ph, 4wire service. Installing new 80kW 120/208V 3ph-Y emergency gen set per applicant, with (2) new EM panels ( ""EM"" and ""EMA""). existing smoke detectors. To replace existing electric heaters with heat pump."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56343	11041-20000-25477	17701 W ORNA DR	91344	12	219B129   681	2601071037	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.29994	-118.51953	New 5.0 KW roof mounted PV system for single family residence.  Applicant is suing the standard plan for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56344	18041-10000-09850	7117 N LAUREL CANYON BLVD	91605	2	183B165   108	2321001010	M1-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM			Corrections Issued	03/24/2018 12:00:00 AM	ADDRESS	34.1998	-118.39673	PC for power and energy for first time Retail & Office tenant. Installing new panels, lights, receptacles andequipment. Total area 8870sqft. B#18016-10000-08176. CHANGE OF USE FROM FACTORY & WAREHOUSE TO RETAIL & OFFICE AT A PORTION OF (E) 1-STORY BUILDING. TENANT IMPROVEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56345	10041-10000-00832	7307 W WORLD WAY WEST 10th floor	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/15/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	07/16/2010 12:00:00 AM	PIN	33.94386821	-118.41794839	TI on the 10th floor in an existing office building at LAX.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56346	14041-20000-16403	11132 W VENTURA BLVD	91604	2	162B173   371	2378009007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.1414	-118.37315	PV2.  Install 32.94 kW DC roof-mounted, utility-interactive PV system.  (3) transformerless inverters.$0 permit fee due to Senate Bill SB-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56347	14041-20001-00923	15834 W SEPTO ST PV1	91343	12	201B141   123	2669025012	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.25091	-118.4774	EXPEDITE FEES ONLY.            <<<INSTALL ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56348	16041-20000-21969	7934 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21495	-118.53476	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56349	15041-10000-19128	2190 W 30TH ST	90018	10	120B189   377	5052025008	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.02728	-118.31476	PV1, ROOF MTD. 29 MODULES, 1 INVERTER, 6.0KW AC. XFORMERLESS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56350	19041-20000-16696	22135 W ROSCOE BLVD LOT #41	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	pv1install roof mounted pv system sized 2.0KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56351	19041-10000-02866	337 S CONWAY AVE	90024	5	138B153   124	4359007008	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM			Verifications in Progress	02/07/2019 12:00:00 AM	ADDRESS	34.07612	-118.43384	PLAN CHECK FOR 5 TESLA POWERWALL 13.5KWH BATTERIES IN A SINGLE FAMILY DWELLING. NO PV SYSTEM. SCOPE INCLUDES 2 NEW LOAD CENTER 200A EACH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56352	14041-10000-16635	6255 W SUNSET BLVD 10thFloor	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Permit to be pulled at EPC counter only. Plan check for energy only. emergency lighting installed. TI to restroom and elevator lobby 10th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56353	15041-20000-03005	7200 W FOOTHILL BLVD Unit 102	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM			PC Approved	03/04/2015 12:00:00 AM	ADDRESS	34.24842	-118.28878	Applicant lost plan. Permit shall not been pull under this application(((T24 for change of use from retail space to yogurt shop. Total collective load does not exceed 400 Amps.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56354	11041-10001-26083	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	33.94386	-118.4047	REVISIONS TO PERMITTED SET OF PLANS-: TEMPORARY EM GENNRATOR REDUCED FROM 80KVA TO 25KVA AND USES A 20 SWITCH TO INPUT TO 5KVA STEPDOWN IPH TRANSFORMERPlan check power and energy for new LAX maintenance building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56355	14041-10001-04952	738 W 20TH ST	90731	15	012B197  1073	7462016024	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2972.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	33.72619	-118.29326	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE5000A-US-ZB-U(23) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56356	15041-10002-18367	8000 W SUNSET BLVD #B135	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM			PC Approved	11/19/2015 12:00:00 AM	ADDRESS	34.09783	-118.36466	changes made to permitted set of plans including lighting - all marked changes are DELTA 2(((((((((PLAN CHECK FOR POWER AND ENERGY FOR NEW ATT STORE FIRST TIME TENANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56357	17041-10001-24177	16307 W STARE ST	91343	12	204B137   816	2678006019	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.25305	-118.48747	Changes to an approved set of plans for a PV system. Changes include relocating Main service panel, adding an additional AC disconnect, and revising single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56358	12041-20000-17980	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005021	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM			PC Approved	08/01/2012 12:00:00 AM	ADDRESS	34.15303	-118.39667	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56359	19041-10000-01015	8716 S RAMSGATE AVE	90045	11	096B169   759	4125015017	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM			PC Info Complete	08/12/2020 12:00:00 AM	ADDRESS	33.95845	-118.38253	FULL PC PWR AND T-24 FOR (N) 5-STORY 30-UNIT  APARTMENT BUILDING. SERVICE 2000A, 208/120V, 3PH, 4W. AREA 43,412SF.(3 EXTREMELY LOW, 2 VERY LOW & 1 LOW INCOME HOUSING) OVER 2-STORY  BASEMENT GARAGE [TOC TIER  3] (NFPA-13 FIRE SPRINKLERS THROUGHOUT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56360	19041-20000-34332	4750 W WILSHIRE BLVD 1ST FLR	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.06185	-118.3338	Plan check for Title 24 only in existing space Tenant Improvement office. Total area: 25,700 sq ft. B#19016-10000-25287	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56361	18041-10000-11552	1030 N SWARTHMORE AVE #4-103	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR FIRST TIME TENANT IN A MALL FOR POWER AND ENERGY. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 650 SQ.FT. B#18016-10000-02831	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56362	17041-20000-45634	3774 W EFFINGHAM PL	90027	4	154-5A203 246	5592004029	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.11689	-118.27576	Plan check for solar pv system w/roof-mounted array on SFD.10.56kW ungrounded system. (33) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56363	19041-20000-49430	16551 W BOSQUE DR	91436	5	165B137   438	2291006012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.14596	-118.49427	New 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56364	11041-10000-03967	5615 W HOLLYWOOD BLVD	90028	13	148-5A193 113	5544003023	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	34.10187	-118.3119	installation of luminaires outdoors for the patio area of existing restaurantplan chk is for title 24PERMIT FOR 4 EA CIRCUITS WILL BE OBTAINED ON SEPARATE CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56365	18041-10000-23084	19191 S VERMONT AVE STE 410	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR OFFICE TI IN A HIGH RISE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS. TOTAL  AFFECTED AREA TENANT IMPROVEMENT WORK ON APPROX. 3,465 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56366	15041-20001-30793	7409 N WESTCLIFF DR	91304	12	186B089   324	2027044008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	PIN	34.20679065	-118.65240976	EXPEDITED FEES FOR ROOF MOUNTED SYSTEM. (((PV1 ROOF MOUNTED SYSTEM, TYING INTO AN EXISTING SYSTEM, INTERCONNECT WITH 225A MSP. (17) MODULES AND (1) UNGROUNDED INVERTER. TOTAL SIZE 3.8KW.(17) KYOCERA #KU2656ZPA(1)SE3800A-US-ZB-US)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56367	13041-20000-20664	5900 W WILSHIRE BLVD FLR 16	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for energy and emergency lighting. 16th floor restrooms. Commercial high-rise. Ratkovich Company.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56368	14041-20000-13976	13263 W VENTURA BLVD	91604	2	165B157   828	2375017005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.14662	-118.42179	"T.I. to a portion of to existing office 2-story building.  Install indoor and outdoor general lighting.  Plan check for energy only. ""COMPLY WITH DEPARTMENT ORDER effective date11/01/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56369	18041-20000-42135	3711 S HILLCREST DR	90016	10	117B181   121	5046032032	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.01966	-118.34339	Plan check for PV roof mounted system, system size: 5.4KW AC  with 15 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56370	18041-10000-31007	2029 W BLAKE AVE	90039	13	148-5A213  73	5442017001	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			08/15/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.10243	-118.24364	Plan check for T24 only, Tenant Improvement to existing Restaurant.  Combine two restaurant spaces into one. Total area: 1,252 sq.ft(B# 18016-10000-25196)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56371	18041-10000-47011	4252 S CRENSHAW BLVD	90008	10	114B185   958	5024017007	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Apartment			12/11/2018 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.00668	-118.33443	Full plan check for a 4-story, 111-unit FACTORY BUILT STATE APPROVED HOUSING apartment building.Scope includes 2000-Amp 120/208v 3phase 4-wire service. Bld application: 18010-10000-02786FA system under #19041-10000-05036	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56372	19041-20001-25136	6617 N BEN AVE pv1	91606	2	180B165   354	2322009052	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1232.04	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	34.19086	-118.39444	expeditepv1install roof mounted pv system sized 11KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56373	18041-10000-41667	3002 W ROWENA AVE	90039	4	151-5A205 190	5434036027	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Issued	10/31/2018 12:00:00 AM	ADDRESS	34.10852	-118.26949	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56374	14041-20000-29698	12621 W DEBELL ST	91331	7	201B161   637	2624015009	RA-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.24682	-118.40883	PV1Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size: 3.8kW. System is ungrounded.12 327W pv modules across two strings (5+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56375	11041-20000-17463	5404 S JANDY PL	90066	11	105B161   885	4211006004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			08/18/2011 12:00:00 AM	10/19/2011 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	33.98159	-118.41622	PLAN CHECK POWER AND ENERGY FOR T.I. TOMS SHOE'S BUILDING. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56376	15041-10000-37316	616 S KENMORE AVE	90005	10	135B197  1102	5502028022	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.06289	-118.29646	INSTALL NEW FA SYSTEM FOR A 6-STORY APARTMENT BUILDING. 117 FA DEVICES, 1 FA PANEL, 1 FA COMMUNICATION APNEL, AND 4 CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56377	10041-20000-20844	2121 S AVENUE OF THE STARS 4th fl-Phase 2	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	12/13/2010 12:00:00 AM	ADDRESS	34.05554	-118.41342	Remodeling offices in a highrise building 4th floor Phase 2.  Plan check for Title 24 Energy and 1 emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56378	19041-20000-00983	7432 N RESEDA BLVD	91335	3	186B125   557	2119017054	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.20567	-118.53585	permit fee $0.00 by senate bill no.1222Plan check for a PV2 roof-mounted PV system. System size is 128.7 kWdc/112.4 kWac and consists of (4) inverters, (390) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56379	16041-10000-12868	20324 W REAZA PL	91364	3	171B113    68	2166035011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.16798	-118.577	PV1, new solar system on existing residential roof-top. Total system size is  9.0kWac.        (36) Solarworld SW275 mono blk    (36) Microinverters-Enphase Energy M250-60-2LL-S25	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56380	15041-10000-30925	633 N SANFORD AVE	90744	15	030B209   385	7424019044	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.77862	-118.25072	Service upgrade to 1200 A,  3 new panels 200 A bus each. connect new equipment over 400 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56381	12041-10000-05678	1355 S FLOWER ST	90015	9	126A205   115	5134010019	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			03/28/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.03876	-118.268	NEW 7-STORY, 80 DWELLING UNITS (76 APARTMENTS AND 4 LIFE/WORK UNITS) COMPLEX WITH SUBTERRANEAN PARKING.PLAN CHECK POWER AND ENERGY. IN METHANE ZONE.VARIANCE TO SEPARATE THE FA PLANS WAS OBTAINED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56382	12041-20000-01079	6100 W WILSHIRE BLVD 2nd & 3rd-Floor	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			Reviewed by Supervisor	01/24/2012 12:00:00 AM	ADDRESS	34.06282	-118.36187	T.I. to a high rise building.  Install new panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56383	14041-20000-22484	20754 W INGOMAR ST	91306	3	189B109   878	2108036020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Expired	09/19/2016 12:00:00 AM	ADDRESS	34.21186	-118.586	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.(1) ABB PVI-6000-OUTD-US-Z-A transformerless inverter(29) Trina Solar TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56384	15041-10000-07929	2334 E 8TH ST	90021	14	123A217   321	5166008006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.02942	-118.23093	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 10980 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56385	19041-10000-52078	3625 S GRAND AVE	90007	9	118-5A203 223	5122023030	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	07/07/2023 12:00:00 AM		Issued	07/07/2023 12:00:00 AM	ADDRESS	34.01785	-118.2778	FULL PC FOR POWER AND ENERGY FOR A HIGH RISE BUILDING. NEW 3000A 480/277 3 PHASE 4 WIRE SERVICE THAT INCLUDES ELECTRICAL EQUIPMENT. ELECTRICAL EQUIPMENT INCLUDE XFMRS, PANELBOARDS, AND A GENERATOR. TOTAL AFFECTED AREA IS 260,000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56386	18041-20000-41776	6109 S CRENSHAW BLVD	90043	8	105B185   609	4006004032	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			10/31/2018 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	04/30/2020 12:00:00 AM	ADDRESS	33.98429	-118.33116	Fire alarm system for new construction 5-story 75-unit apartment building.  164 signaling and notification devices and FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56387	19041-10000-51118	1204 S DANIELS DR	90035	5	132A165   176	4330017013	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	34.056	-118.40182	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTIMIZERS. (1) INVERTER, (22) MODULES, AND (22)OPTIMIZERS. TOTAL SYSTEM SIZE IS 6.380KWDC/5KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56388	15041-10000-01467	10243 N HAYVENHURST AVE	91343	12	204B137   368	2685015016	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.2569	-118.49377	Installation of new roof mounted solar PV system.  7.75 kW microinverter system consisting of (31) 250 W modules (2 strings)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56389	10041-10002-18263	6150 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	33.94474	-118.39224	"Plan check is for temporary trailor that is actually four trailors connected to form one.  The trailor will be placed inside the hangar. <<<<<TI IN AN EXISTING OFFICE AREA AND HANGER AT LAX FOR ""RATHEON"" (ADJACENT TO DELTA HANGER).  PLAN CHECK IS FOR POWER AND ENERGY.>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56390	10041-10000-25452	634 W 34TH ST 1st floor	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Info Complete	01/14/2011 12:00:00 AM	PIN	34.02192429	-118.28551249	T.I. to partial of 1st floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56391	18041-20000-43160	23710 W CARARD ST	91367	3	174B089   345	2045025019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.1734	-118.64489	Plan check for a PV1 roof-mounted PV system. System size is 7.08 kWdc/6.47 kWac-CEC and consists of (1) 7.6 kWac rated inverter and (24) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56392	12041-10000-12778	10230 N SEPULVEDA BLVD	91345	7	204B145   388	2660016028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.02	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.25618	-118.46707	"Remodel of an existing Car Dealer, upgrade to 1200Amp service, new subpanels, circuits, lighting.  Full plan check.  ""COMPLY WITH DEPARTMENT ORDER effective date 01/21/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56393	17041-20001-25745	15206 W PARTHENIA ST	91343	6	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.2281	-118.46381	expeditepv2install roof mounted pv system sized 55kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56394	14041-10000-28945	10979 W BLUFFSIDE DR BLDG 3	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.14174	-118.36926	Note to plan check engineer, applicant returns and swaps in a new plan with additional circuits added on after original fee was paid. Plan check engineer needs to verify fee with all new changes. Per F.Y.(((Installing new washer/dryers and booster fans in apartment units.  Bldg 3 of 6.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56395	14041-20000-16746	7909 N NITA AVE	91304	3	189B101   441	2012009012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.214	-118.61384	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56396	17041-20001-29802	4734 N CEDROS AVE	91403	4	169-5A149 267	2265003032	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.15702	-118.45293	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.5 kWac and consists of (42) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56397	13041-20001-06860	20832 W VALERIO ST #22	91306	3	186B109  1048	2113013***	(Q)RD2-1, (Q)RD6-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.20456	-118.58754	(((SUPP. APPLICATION FOR CHANGE IN PANEL. SOLAR PANEL IS NOW YINGLI YL-250. PLAN CHECK ONLY APPLICATION. PERMIT ALREADY ISSUED FOR PANELS UNDER ORIGINAL APPLICATION. )))photovoltaic system for single family dwelling. zoned as a condo. total system size 4.4 kw. using 18 panels. non standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56398	16041-20000-44870	139 S OCCIDENTAL BLVD	90057	13	136-5A201  39	5155004021	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Apartment			12/21/2016 12:00:00 AM			PC Info Complete	08/15/2017 12:00:00 AM	ADDRESS	34.06992	-118.28097	Plan check for power and energy. New 5-story 48-unit apartment building. 3 typical units. 1600A service. T24: indoor - 34,430sqft; outdoor - 3,335sqft. Fire alarm variance is on file.building permit # 16010-10000-05277	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56399	12041-20000-29944	4750 W WILSHIRE BLVD	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00, 2161.00	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.06185	-118.3338	T.I. to 1st, 2nd, and 3rd floors of an existing low-rise commercial building.  Load is greater than 600 amps.  New subpanels, circuits, lighting, Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56400	14041-20000-16177	7545 N SAN FERNANDO ROAD BLDG 2	91505	2	186B177   570	2466036010	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.20906	-118.35474	T.I. to existing warehouse, office, manufactureing building.  Install general/emergency lighting in office area.Relocate general lighting in the warehouse area and reconnect to existing circuits.  Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56401	10041-10000-20002	3901 S WESTERN AVE	90062	8	117B193  1416	5035017001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	04/05/2011 12:00:00 AM	ADDRESS	34.01444	-118.30916	fire alarm for one story dialysis center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56402	15041-10000-21700	2415 W AVENUE 30	90065	1	150B213   548	5457010028	R3-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Public Safety Only			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.1068	-118.2385	NEW FIRE WARNING SYSTEM IN A CHILD CARE CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56403	18041-10001-43449	17915 W ERWIN ST	91316	5	177B129    15	2123022022	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.184	-118.52364	SUPPLEMENTAL FOR FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED 10KVA PV SYSTEM REMOTELLY MOUNTED ON GARAGE CONSISTING OF 1 CENTRAL INVERTER(10000H-US) WITH 23 MODULES USING P320 OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56404	11041-10000-03825	"3327 E SABINA ST Bldg ""A"""	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			03/01/2011 12:00:00 AM	05/18/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	"NEW FIRE ALARM SYSTEM IN THREE BUILDINGS A, B & C.  THIS PERMIT IS FOR BLDG ""A"". <<<<<<<BLDG ""B"" PERMIT # 11041-10001-03825 AND BLDG ""C"" PERMIT # 11041-10002-03825>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56405	12041-10003-05876	8900 N CORBIN AVE	91324	12	195B117    43	2783025026	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Info Complete	02/04/2013 12:00:00 AM	ADDRESS	34.23252	-118.56211	SUPPLEMENTAL OF 12041-10002-05876. RELOCATION OF PANEL, RECONFIGURATION OF BRANCH CIRCUIT LOADS. NEW OUTDOOR LIGHTING.  *************************12041-10002-05876 DESCRIPTION: SHELL STATION. NEW 225A PANEL. ADDING NEW FUEL PUMPS IN CLASS I, DIVISION I HAZARDOUS AREA. PLAN CHECK FOR LIGHTING AND POWER. 768 SQFT CANOPY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56406	13041-20000-08911	7514 N LANKERSHIM BLVD	91605	6	186B169   445	2316013003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	34.20703	-118.38758	Install new 600 Ampere overhead service to supply future panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56407	18041-10001-28121	3501 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.06371	-118.2982	Changes to approved plans. Additional 5 devices to the Fire Alarm System. (((Install new Fire Alarm System Core and shell/Change of use from residential studio to office. Building is historical. (1) FACP, (115) devices)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56408	11041-20000-02861	8941 N TAMPA AVE #103	91324	12	195B117    25	2783028013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.23285	-118.55413	Plan check T24 Energy/Emergency lighting for TI suite #103 Sarku Japan	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56409	13041-10001-30569	1800 N ARGYLE AVE	90028	13	150A189   301	5546033015	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM			PC Info Complete	09/11/2015 12:00:00 AM	ADDRESS	34.10384	-118.32506	This application for plan check only.  Permit is issued under 13041-10000-30569PLAN CHECK FOR POWER AND ENERGY. 16 STORY HIGH RISE HOTEL WITH 200 ROOMS. mzandi    04-27-2015   changes to original design,  lighting changed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56410	16041-10000-44270	1600 S GAFFEY ST	90731	15	012B197   427	7454034031	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.01	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	33.72959	-118.29219	INSTALLATION OF NEW 20.52 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING  CONSISTING OF (76) MODULES: CANADIAN SOLAR CS6K-270M BLACK(2) INVERTERS: SOLAREDGE SE7600A-US(240V)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56411	17041-20000-46642	1452 N AVENUE 57	90042	14	157-5A229 281	5485016001	RE11-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	Yes	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Expired	09/13/2023 12:00:00 AM	ADDRESS	34.12517	-118.19359	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. Existing solar pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56412	13041-20003-16949	7528 N KRAFT AVE	91605	6	186B169   384	2316010026	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.20742	-118.38001	Modifications to approved set.  Modules on detached garage rooftop removed.  (((PV-1 Plan check for 11.5KW roof mounted photovoltaic system. Ungrounded system using Power-One inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56413	17041-10001-23328	11401 N PORTER RANCH DR BLDG 1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	06/28/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDE REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 1 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 33 unit apartment with 1600 amp 208 volt service.       Building 1 of 10.  Type III.       Building permit #17010-10000-02377	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56414	12041-10001-26781	6148 W PICO BLVD	90035	10	129B173   180	5068001005	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.05298	-118.37549	PC FOR power only , title 24 was approved under 12041-10000-26781.  Inspector sent applicant back for load calculation and PC power approval to make sure service is okay for the load.  Change of use from retaail to dry cleaning. changed panel B2 from single to three phase during plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56415	16041-20003-16708	3400 W SUNSET BLVD	90026	13	144A203   344	5427026021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.08744	-118.27608	12/17/19CHANGES TO APPROVED SET DELTA 10 ONLY CHANGES TO LIGHTS IN LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56416	16041-20000-15426	201 N FIGUEROA ST 13th floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for Title 24 only in existing high-rise building. Total area: 11,081 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56417	18041-10001-20342	6505 S ESPLANADE #4	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	33.96159	-118.45071	4 OF 5******EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56418	15041-10000-26765	7424 N HASKELL AVE 1-35	91406	6	186B141   418	2206028014	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Info Complete	08/17/2015 12:00:00 AM	ADDRESS	34.20546	-118.47476	ADDITION OF EXIT SIGNS TO AN APARTMENT BLDG IN CORRIDORS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56419	13041-10000-28634	5125 N LANKERSHIM BLVD	91601	2	171B173   800	2353004027	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.16376	-118.37417	Remove HID light fixtures and replace w/ fluorescent fixtures.  Title 24 plan check only, permit to be issued at EPC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56420	12041-20000-17804	7540 N SEPULVEDA BLVD	91405	6	186B145   247	2221001025	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.20774	-118.46601	T-24 lighting plan check for a portion of a food market.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56421	17041-10000-20895	777 S FIGUEROA ST #900	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for power and Title 24.  Office T.I. to suite 900 of existing commercial highrise.  Three new subpanels and one new 75 kVA transformer.  New lighting and receptacle loads > 400 amps.  Lighting area = 17,280 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56422	18041-10000-11111	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.08469	-118.4849	PC for power only. Scope includes adding a new 800A 120/208V 3 phase 4 wire service/distribution board for USC Rossiter Hall Student Housing. Replacing existing panelboards and refeeding existing equipment. Adding new Fan Coil units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56423	14041-10000-34869	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM			Corrections Issued	12/16/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	Plan check for Title 24 only. Project is in an existing commercial space (Sbarro's). Total lighting area = 376 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56424	14041-10000-06333	1305 W SEPULVEDA BLVD	90501	15	042B197    11	7347018005	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	33.81372	-118.29936	FULL PLAN CHECK FOR FIRST TIME TENANT(WELLS FARGO BANK). TOTAL AREA 4250 SQ FT. BULDING PERMIT# 14016-10000-04289.PLAN CHECKER PLEASE VERIFY THE # OF DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56425	11041-10000-20041	444 N NORTH FARING ROAD	90077	5	141B153    24	4358007007	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2011 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.08651	-118.43273	NEW ELECTRICAL SERVICE FOR A SINGLE FAMILY RESIDENCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56426	15041-20000-27126	16445 W TRIBUNE ST	91344	12	207B137   173	2680015003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.26673	-118.4909	Plan check for PV roof mounted system. System size: 3.8kW with 14 modules and 1 inverter(3.8kW). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56427	16041-10000-15587	8621 S BELLANCA AVE	90045	11	096B169   625	4125016030	MR1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			Corrections Issued	05/04/2016 12:00:00 AM	ADDRESS	33.95929	-118.38073	PC for energy only to a commercial site (Los Angeles Healing Center). Work is being done on second floor for a two story building. Adding new lighting only. All Equipment is existing. Total Sqft = 300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56428	18041-20000-47435	1454 S HI POINT ST 1-8	90035	10	129B173   646	5068017037	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			12/14/2018 12:00:00 AM	02/21/2020 12:00:00 AM		Permit Finaled	02/05/2021 12:00:00 AM	ADDRESS	34.0503	-118.36893	Plan chek for power only in existing building, service upgrade 600A with new feeders and panel, load existing to remain with addtion of A/C load in each unit, additon of laundry circit for each unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56429	19041-10000-09576	4209 W WASHINGTON BLVD	90016	10	126B185   927	5071002042	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			Verifications in Progress	10/23/2019 12:00:00 AM	ADDRESS	34.04003	-118.33134	Plan check canceled per contractor Joe Nguyen on 11/08/2019. License #850795FULL PLAN CHECK FOR PROPOSED TENANT IMPROVMENT FOR 7-ELEVEN CONVENIENCE RETAIL STORE. NEW 600A DIST. BOARD, (4) NEW PANELBOARDS, ALL CONNECT TO (E) SERVICE IN THE BUILDING. TOTAL AREA UNDER THE SCOPE APPROX. 2,585 SQ.FT Plan check canceled per contractor Joe Nguyen on 11/08/2019. License #850795<<TO ADD NEW PARTITIONS, COUNTERS, FINISHES. EXTERIOR ALTERATIONS TO ADD NEW MECHANICAL EQUIPMENTS ON ROOF. B# 18016-10000-37901>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56430	14041-10001-24758	380 WORLD WAY Space 89	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to approved set.  PC at request of inspector.  Removal of dimming from title 24 sheets.***** Previous Work Description*****Title 24 plan check only.  Total area = 24 sq. ft.TI to airport terminal kiosk.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56431	13041-10000-05261	7172 W MELROSE AVE	90036	5	141B181   635	5525015004	C2-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM			PC Approved	03/08/2013 12:00:00 AM	PIN	34.08320991	-118.34588198	RENOVATION OF EXISTING RETAIL SPACE FOR USE IN RETAIL. NO CHANGE OF USE. PC FOR T24 ENERGY ONLY. CONTRACTOR WILL PULL PERMIT FROM PC STAFF. TOTAL AREA 2903 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56432	10041-20000-02491	6720 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	34.11789	-118.33923	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56433	18041-20001-22980	13181 W MINDANAO WAY	90292	11	105B153   104	4212004007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	33.98449	-118.43785	8/14/2018changes to an approved set of plans.  changes to alter the existing lighting and recalculate energy installed wattage.  This is plan check only.(((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,043 sq. ft.Note: Building application has been generated under 17016-10000-03999)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56434	12041-10000-24251	4601 W PROSPECT AVE	90027	4	147B197   215	5590026021	RD1.5-1XL	Central	Hollywood	Greater Griffith Park		1891.01	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.10191	-118.2898	AT AN EXISTING CHURCH , NEW PANELBOARDS ARE ADDED TO SUPPLY NEW AC UNITS AND LIGHTING CIRCUITS-ADDED LOADED IS LESS THAN 300APLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56435	19041-10000-13842	17840 W VENTURA BLVD	91316	5	171B129   478	2182002014	C4-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	03/10/2020 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.16305	-118.52135	Full PC PWR AND ENERGY FOR RALPH'S STORE (RENOVATION). EXISTING SERVICE. AREA OF SCOPE 30,330SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56436	18041-10000-31244	5951 S BROADWAY	90003	9	105B201   400	6005004001	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2392.01	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.98589	-118.2785	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56437	19041-10000-36719	6500 W HOLLYWOOD BLVD	90028	13	148-5A187 179	5547016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	02/19/2020 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.10143	-118.33126	PLAN CHECK FOR POWER ONLY FOR SERVICE UPGRADE - NEW SERVICE RATED AT 800A 120/240V 3 PHASE WITH HOUSE PANEL.-7 ELEVEN - DONE BY OTHERS UNDER PERMIT 18041-10000-39721-JOE PIZZA- EXISTING 12 MOTH PEAK DEMAND IS INCLUDED-HOUSE PANEL - HOUSE PANEL (EXISTING) - LOAD TO BE DETERMINED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56438	11041-10000-12748	400 W WORLD WAY WEST TERMINAL-# 4	90045	11	090B165   100	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	05/23/2012 12:00:00 AM	PIN	33.94386803	-118.39979044	REPLACEMENT OF 9 ELEVATORS IN TERMINAL 4 AT LAXPLAN CHK IS REQUESTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56439	19041-10000-02475	11111 W SANTA MONICA BLVD 12th floor	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.04771	-118.44481	ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT OF CORRIDOR AND RESTROOMS FOR EXISTING OFFICE BUILDING ON THE 12TH FLOOR. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 965-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56440	16041-20001-25393	16741-16753 W SCHOENBORN ST	91343	12	192B137   231	2689012013	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	34.2228	-118.49793	9.20.2016 - Plan check 800A MSP replacement per inspector request. Permit pulled under parent application.=====ONE FOR ONE REPLACEMENT OF 800 AMP SERVICE BOARD WITH FOUR METERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56441	11041-20000-11835	555 W 5TH ST 16th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Finaled	02/17/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I. on the 16th floor of a high rise building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56442	10041-10000-03807	1415 W TORRANCE BLVD	90501	15	054B193   315	7351020019	M2-1VL, MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Public Safety Only			03/03/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	05/10/2010 12:00:00 AM	ADDRESS	33.84207	-118.30215	NEW FIRE ALARM SYSTEM TO MONITOR THE FIRE SPRINKLER SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56443	10041-20000-11821	2121 S AVENUE OF THE STARS #2230	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check T-24 Energy general/emergency lighting for office spaces for suite #2230	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56444	10041-20000-02725	4312 N WOODMAN AVE Unit 102	91423	2	165B157   591	2360006060	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM	02/17/2010 12:00:00 AM		Permit Finaled	04/20/2010 12:00:00 AM	ADDRESS	34.14854	-118.43103	CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE ON THE FIRST STORY OF AN TYPE V-1HR. FULLY SPRINKLERED BLDG -	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56445	19041-20000-50902	555 S FLOWER ST 34TH FLR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	06/15/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for Title 24 Energy only new lighting and lighting control in the area. Total area: 7600 sq ft. B#19016-10000-38545	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56446	14041-10001-28817	12154 W MONTAGUE ST	91331	7	204B165    89	2537018027	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM			PC Approved	04/14/2015 12:00:00 AM	ADDRESS	34.25712	-118.39806	SELTA 4 REVISIONS: SOME FEEDERS CHANGED TO AL CONDUCTORS; REDUCTION OF NUMBER OF LUMINAIRESAS BUILT SET OF PLANSPC FOR POWER AND ENERGY. COMMERCIAL TI TO EXISTING OFFICE SPACE INCLUDING OFFICES, BREAK ROOMS AND RESTROOMS. TOTAL AREA 30415 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56447	19041-10000-48061	6321 S WEST BLVD	90043	8	105B185  1000	4004034020	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	33.98203	-118.33536	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56448	16041-20000-31881	14855 W NAVARRE WAY	91342	7	219B149   648	2611007050	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29549	-118.45508	"Fully sprinklered 47' x 21' irreg. shaped 2 story SFD with attached 2 car garage(Plan #1490), LOT 49.   ""Small lot subdivision pursuant to Tentative Tract Map No. VTT-68157-SL-M1.  A certificate of occupancy (temporary or final) shall not be issued until after the final map has been recorded."""	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56449	18041-10000-42406	8110 S AIRPORT BLVD	90045	11	099B169   982	4105017021	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.96519	-118.38502	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56450	14041-20000-01744	1811 N WESTERN AVE	90028	13	150A193   287	5544004033	[Q]C4-2D	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	PIN	34.10384665	-118.30970193	energy plan check ahf research	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56451	19041-30000-14879	8514 W HILLSIDE AVE	90069	4	148-5A173 319	5558028033	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Expired	11/08/2023 12:00:00 AM	ADDRESS	34.10108	-118.37336	Plan check for a PV1 roof-mounted PV system. System size is 14.49 kWdc/10 kWac and consists of (1) inverter and (46) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56452	14041-10000-09120	3502 S WATT WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.02207	-118.28645	T24 FOR EXISTING COMPUTER LAB TURN INTO OFFICE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56453	19041-20000-43386	15303 W VENTURA BLVD Ste 1260	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	Power and lighting for tenant improvement.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56454	13041-10000-18884	323 S ANITA AVE	90049	11	129B141   236	4405031014	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.05211	-118.48158	PV1 4.9kwXFRMless. 2STORY. nonSTD. ROOFMOUNT. [ 1INV: solaredge SE5000A-US] [ 20MOD: TRINA TSM-245PC05.18} with optimizers] POWERBOX 250W OP250-LV-MC4SM-2NA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56455	16041-10000-29437	501 S SHATTO PL	90020	13	135B197   762	5077003032	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.06509	-118.29014	Installation of new fire alarm system in existing 5 story commercial building.  Total system size = 277 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56456	13041-20000-26679	4671 W 62ND PL	90043	8	105B177   347	4002024026	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	33.98289	-118.35777	PV1 TRANFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.25KW. 13 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56457	18041-10000-25362	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Issued	07/09/2018 12:00:00 AM	ADDRESS	34.13829	-118.34154	NEW FIRE ALARM PANEL IN A RECREATIONAL BUILDING, TOTAL OF 52 FA DEVICES AND 1 NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56458	19041-10000-53361	20000 W PRAIRIE ST	91311	12	198B113   168	2761001***	MR2-1, PF-1XL, [T]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			Reviewed by Supervisor	01/08/2020 12:00:00 AM	ADDRESS	34.23899	-118.56833	PLAN CHECK FOR TI ON EXISTING BUILDING CONNECTINGTO EXISTING SERVICE. SERVICE SIZE IS 5000A 3PH 4W. TOTAL AFFECTED AREA IS 31089 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56459	15041-10000-43530	5823 S VILLAGE DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	33.97543	-118.41544	Full plan check for a new building under a single plan, located in the same job site of a Methane ZONE, consists of  (6) new stand alone buildings with (6) different addresses and application numbers; Each building is identical and has 4-story and 6 units supplied by a 600-Amp service;  All electrical work for the plan are identical to  reference electrical applicaton #15041-10000-27550 located at the same site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56460	18041-10000-17363	1602 W LOCKNESS PL	90501	15	045B193   449	7347017040	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	33.81805	-118.3056	REPLACE INDOOR / OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56461	18041-10000-41496	6556 W HOLLYWOOD BLVD	90028	13	148-5A187 187	5547015017	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM			Corrections Issued	10/30/2018 12:00:00 AM	ADDRESS	34.10141	-118.33294	PC FOR T-24 ONLY, 2 NEW CKTS FOR TRACK LIGHTING IN EXISTING RETAIL STOREBUILDING PERMIT #18016-10000-33172	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56462	15041-10000-35177	4760 W SUNSET BLVD RECEPTION	90027	13	147B197   733	5543015021	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.09788	-118.29343	T-24, TI TOA  KAISER RECEPTION LOBBY ONLY, NO PATIENT CARE AREAS. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 442	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56463	14041-20000-06474	8902 S SEPULVEDA BLVD	90045	11	096B165  1026	4123001031	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	33.95571	-118.39596	PLAN CHECK FOR POWER AND ENERGY FOR RENEVATION OF EXISTING SPACE DIVIDING INTO TWO SEPERATE SPACES. EVERYTHING IS NEW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56464	11041-20000-20686	9301 N TAMPA AVE 29B back	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	09/28/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	energy plan check cooridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56465	18041-10000-04171	11608 W CULVER BLVD	90066	11	111B161   683	4217018032	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	07/20/2021 12:00:00 AM	ADDRESS	33.99904	-118.41413	Full plan check for New mix  use apartment building, service at 2000A, 240/120 V, 3ph, 4W, Delta system. Total area for energy plan check SOW: 31,723 sq.ft indoor + 11,178 sq.ft outdoor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56466	19041-20001-25977	7731 N HAYVENHURST AVE B	91406	6	189B137   123	2205009092	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	34.21159	-118.49261	12/5/19CHANGES TO APPROVED SET DELTA 2 ONLY CHANGES TO SERIES RATED BREAKERS AND MAIN BREAKER. <<<FULL PLAN CHECK CHANGE OF USE FROM WAREHOUSE TO WAREHOUSE/MANUFACTURING AND RETAIL.  AREA OF SCOPE IS 22,700SF. EXISTING SERVICE SIZE IS 600A, 277/480V, 3PH.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56467	14041-10000-14701	742 S WILTON PL	90005	4	132B189   510	5092027010	R3-1	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Expired	08/03/2016 12:00:00 AM	ADDRESS	34.05858	-118.31411	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. NON STANDARD PLAN. SYSTEM SIZE: 3.06 DC.(1) SOLAREDGE SE3000A(12) TRINA SOLAR TSM 255P(12) POWEROPTOMIZERS P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56468	17041-20002-23707	3274 S VETERAN AVE	90034	5	120B157   501	4254020020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.02511	-118.42006	8/30/17changes to an approved set of plans.  changes include updating single line diagram, removal of tesla powerwall.  this is plan check only.(((Plan check for roof-mounted solar pv system w/AC coupled battery backup system (on SFD).System size: 6.16kW ungrounded.(22) EnPhase IQ6PLUS microinverters.(22) 320W pv modules.(1) 5kW Tesla Powerwall 2.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56469	13041-10000-02526	1828 E CESAR E CHAVEZ AVE	90033	14	130-5A221 325	5174008022	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	08/23/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.05014	-118.21571	EXISTING CORE AND SHELL, PC FOR TENANT IMPROVEMENT. FIRST TIME TENANT. MEDICAL CLINIC OUT PATIENT FACILITY. PC FOR POWER AND ENERGY, T24. TOTAL 1466 SQ FT. 6th floor. Fire variance submittedAPPLICANT HAD PRE-MADE CHECK. VERIFY FEES. TOTAL COUNTER COUNT OF 23 CIRCUITS, 2 LIGHTING CIRCUITS @ 277V. NO ADDITIONAL POWER EQ.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56470	18041-10000-26012	1250 W SUNSET BLVD	90026	1	136-5A211  53	5405022003	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	06/06/2023 12:00:00 AM	ADDRESS	34.06983	-118.25066	PC FOR POWER AND ENERGY FOR NEW BREWERY. SCOPE INCLUDES NEW SERVICE AT 600A 3PH 120/208NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA   5953 SQ.FT.  INDDORS AND OUTDOORSB#17016-10000-37729	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56471	13041-10000-08681	11546 W CANTON DR	91604	2	159B169   358	2377016020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.13288	-118.38537	PV1 ROOF MOUNTED SOLAR INSTALLATION ON 2 STORY FAMILY DWELLING. 48 MODULES. SYSTEM SIZE IS 11.76 KW.. USING TWO INVETERS WITH TWO STRINGS PER INVETER. [INVETER: SMA AMERICA # SUNNY BOY SB6000US AND SMA AMERICA # SUNNY BOY SB5000US  |||| MODULES: REC SOLAR # REC245PE(BLK)]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56472	13041-10000-18778	3031 S VIRGINIA ROAD	90016	10	120B185   620	5050027050	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.02661	-118.33958	PV1. Single story house. Roof mounted PV. System size 2.16 kw. 9 modules: hanwha solar hsl60p-pa-0-240k. 9 Micro Inverters : Enphase Energy m215-60-2ll-s2x.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56473	18041-20000-45049	24228 S ROSCOE BLVD	91304	12	192B089   200	2017039011	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.21938	-118.65502	Plan check  for PV roof mounted system, system size: 2.835kW with 9 PV Modules and 1 inverter(3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56474	11041-10000-21191	864 E JEFFERSON BLVD	90011	9	117A207   308	5114001013	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM			PC Approved	10/04/2011 12:00:00 AM	ADDRESS	34.01356	-118.26138	T.I. for and existing warehouse.  PLAN CHECK ONLY for ENERGY, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56475	17041-20000-34496	12354 W HUSTON ST	91607	2	168B165   266	2356029002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.15929	-118.4027	Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.3.8kW ungrounded pv system. (12) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56476	13041-10001-24796	8053 W BEVERLY BLVD	90048	5	138B177   392	5514007045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM			Corrections Issued	11/04/2014 12:00:00 AM	ADDRESS	34.07625	-118.36499	install 200 amp panel. new title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56477	16041-10000-04950	1787 W 37TH DR	90018	8	117B193   329	5041035047	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Expired	03/13/2018 12:00:00 AM	ADDRESS	34.01945	-118.31152	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.40KWdc/4.3KWac. (20) MODULES-SUNEDISON SE-270KzD-3Y(20) MICROINVERTERS-M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56478	19041-20000-00596	6113 N MARY ELLEN AVE	91401	2	177B157   595	2331024042	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Issued	01/07/2019 12:00:00 AM	ADDRESS	34.18166	-118.4194	Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWdc/13.48 kWac-CEC and consists of (42) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56479	12041-20000-01437	8917 N LANKERSHIM BLVD	91352	6	195B169   232	2631015041	(F)CM-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	ADDRESS	34.23141	-118.38808	new warehouseEnergy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56480	12041-20001-01881	18025 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM			PC Approved	02/10/2012 12:00:00 AM	ADDRESS	34.2649	-118.5256	revision to approved energy plans	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56481	16041-10000-12370	2919 W LOS FELIZ BLVD Suite #1	90039	13	157-5A207 375	5594006023	[Q]C4-1XL-RIO, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.12656	-118.26333	Title 24 plan check only.  Total area = 1,296 sq. ft.     T.I. to existing commercial retail space.  One new subpanel.  New lighting, receptacles, and emergency inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56482	10041-10000-16166	1212 E PALMETTO ST	90013	14	126A215   160	5164001902	PF-1XL	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	08/25/2011 12:00:00 AM	ADDRESS	34.03997	-118.23549	New 50kw P.V.  system for existing commercial building.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56483	12041-10001-18985	15359 W OXNARD ST	91411	6	177B145   440	2242001020	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM			Verifications in Progress	12/05/2012 12:00:00 AM	ADDRESS	34.17957	-118.46823	New Fire Alarm for            <<<<Replace existing underground process gravity drainage piline and UST with new lift stations.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56484	13041-10000-27903	10857 N RESEDA BLVD	91326	12	207B125    23	2717015005	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.26803	-118.53641	PV1, 7KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(28)modules: {TRINA SOLAR  {#TSM-250PA05.18}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP259-LV-MC4SM-2NA-Z}. (E) 200A MAIN. THE 250W OPTIMIZERS WILL BE CHARGED UNDER NON-DWELLING POWER EQUIPMENT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56485	15041-20000-16272	936 S OLIVE ST UNIT 255	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #4 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56486	19041-10001-00144	929 W JEFFERSON BLVD UNIT 1660	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.02454	-118.28546	Supplement to an approved plan, scope include adding a bugeye to service area and reducing fixture AE from 8.6w/f to 1.7w/f	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56487	15041-10000-32610	437 S HILL ST	90013	14	130-5A211 148	5149027013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.0495	-118.2514	Install NEW Methane Detection System 24 devices on a NEW 8-story mixed-use Bldg. with 2 subterranian parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56488	13041-10000-31463	1236 W LEIGHTON AVE ste#3	90037	8	117B197  1164	5037003003	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.01307	-118.29858	PV1, Install 3 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US.  12 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56489	14041-10001-04958	2921 E CALLE PEDRO INFANTE	90063	14	124-5A225 260	5185019016	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.03455	-118.20535	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(14) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56490	13041-10000-31255	380 WORLD WAY T43-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLANCHECK FOR T24 ENERGY ONLY ( SIGN LIGHTING). LAX STOREFRONT SIGNAGE. PORSHE DESIGN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56491	19041-10000-53465	10848 W VICTORY BLVD	91606	2	180B173   877	2414008038	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Apartment			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	34.18653	-118.36762	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56492	13041-10000-27886	4200 W 59TH ST	90043	8	105B181   246	4019009016	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	33.98698	-118.34763	PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 3.5 kW.  TRANFORMERLESS. UNGROUNDED. POWER OPTIMIZER.(14) TRINA SOLAR # TSM-250PA05.18(14) POWER OPTIMIZER(1) SOLAREDGE # SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56493	17041-20000-45358	941 W 35TH ST	90089	9	120A201    44	5039012030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Closed	05/22/2018 12:00:00 AM	PIN	34.02328797	-118.28705198	"Use existing ""MSS"" switboard to feed new ""DBLDSR"" switchboard and associated panels and loads down stream and refeed existing panel ""MCC BMCC"".  Replacement of receptacles and associated wiring in BSR Residence Hall at USC. Plan check for power only."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56494	17041-20001-04899	11711 W PICO BLVD	90064	11	123B149   653	4260029033	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM			PC Approved	06/11/2018 12:00:00 AM	ADDRESS	34.03159	-118.44613	New plan design for lighting system for office addition. Plan check for energy.  (((Office addition to (E) commercial structure.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56495	15041-20004-28493	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	34.24143	-118.56249	1/28/16  CHANGES TO APPROVED SET. DELTA 6 CHANGES ONLY. REDUCING THE FEEDER SIZE TO THE 30 KVA CONVERTER TO #4 . 12.23.2015 - Plan check for modifications to approved set of plans - delta 5 changes only. Adding a new 30kVA - 400Hz converter(Variance has been submitted for approval prior to equipment listing), 400Hz distribution panel, and 400Hz branch circuits serving lab (incl. receptacles). *****Previous Work Description*****12/23/2015 Changes to an approved set of plans. Changes include revisions of power plan and the addition loads. All changes have been clouded and marked as Delta 1, 3, and 4.*****Previous Work Description*****Plan check for power and energy for T.I. work within existing space. Total indoor area: 4,536 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56496	19041-20000-13478	20200 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Issued	04/12/2019 12:00:00 AM	ADDRESS	34.27515	-118.57076	INSTALLATION OF A 75KVA TRANSFORMER, 400A PANEL, 400A SERVICE, AND A 200A PANEL WITH 2 3.8KVA EQUIPMENT, AND 34 NEW BRANCH CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56497	12041-10000-10943	1516 N KINGSLEY DR	90027	13	147A195    50	5544015033	RD1.5-1XL	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			05/11/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.09878	-118.30311	sprinkler monitoring system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56498	16041-20000-18550	19333 W SANTA RITA ST	91356	3	171B117    96	2163004011	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.16778	-118.5546	PV1Install photovoltaic roofing shingles on a SFD. Interconnect with a 200A MSP.System size: 4kW. Ungrounded system. (208) 23W sunslate roofing shingles.Resubmittal of plans - original submittal under 15041-20000-14421.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56499	12041-10000-06379	4155 N FARMDALE AVE	91604	2	162B169    61	2368022023	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2012 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.14404	-118.38129	New 6.96kw photovolatic, rooftop system for an existing sfr.  System uses Enphase Inverters, with 29 panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56500	19041-10000-44717	1515 W 190TH ST STE 550	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	Energy PC only,  Area of Scope 426 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56501	18041-20000-45046	24220 S ROSCOE BLVD	91304	12	192B089   199	2017039010	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.21938	-118.65478	Plan check for PV roof mounted system, system size: 2.835kW with 9kW with 3.0kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56502	14041-20000-21171	12154 N BEAUFAIT AVE	91326	12	219B121   267	2870004015	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Expired	09/06/2016 12:00:00 AM	ADDRESS	34.29405	-118.53918	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(21) TRINA SOLAR TSM-255 MODULES(1) POWER ONE PVI-4.2-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56503	19041-10000-23373	612 S BROADWAY	90014	14	129A211   216	5144002019	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	02/28/2020 12:00:00 AM		Permit Finaled	08/25/2021 12:00:00 AM	ADDRESS	34.0462	-118.25221	FULL PLAN CHECK FOR A  RETROFITTING 8-STORY HIGH RISE BUILDING AND OFFICE T.I. FROM FROM 2ND FLOOR TO 6TH FLOOR. SCOPE INCLUDES A NEW 1000-AMP 277/480V SERVICE WITH A TOTAL LIGHTING AREA OF 71,875 SQ FT.BUILDING PERMIT # 17016-10000-38600                                     #18041-10000-13480 (for core / shell referrence)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56504	19041-20000-36486	5153 N WINDERMERE AVE	90041	14	163-5A221 248	5671020012	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	11/23/2019 12:00:00 AM	ADDRESS	34.1413	-118.21729	PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.8KW DC/ 4.188KW AC. SCOPE OF WORK CONSISTS OF (12) PV MODULES WITH INTEGRATED MICROINVERTERS AND (2) 100A SOLAR LOAD CENTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56505	19041-20001-28663	22720 W MARTHA ST pv1	91367	3	174B097   501	2040011026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	34.17265	-118.62192	expeditepv1install roof mounted pv system 9.4KW AC interconnected with msp.(1) tesla ESS rated 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56506	12041-20000-06032	3000 W 6TH ST	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM			PC Approved	03/16/2012 12:00:00 AM	PIN	34.06351748	-118.28745252	Plan check only. new emergency lighting.  Permit under#12041-10000-06106	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56507	16041-20000-42686	6800 N VARIEL AVE	91303	3	183B105   995	2138023045	(Q)R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1349.03	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.19402	-118.59264	New 5-story 18-unit residential condo/garage (4 stories residential over 1 story garage). 1200A 120/240V 3ph-4w service. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56508	14041-10000-12050	210 W 7TH ST #3	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			Corrections Issued	05/06/2014 12:00:00 AM	ADDRESS	34.04461	-118.25275	T24 FOR SIGN INSTALLING FOR CVS PHARMACY. #2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56509	09041-10002-15447	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM			PC Approved	07/06/2010 12:00:00 AM	ADDRESS	34.27548	-118.56626	"Changes from previously approved plans.  Changes include relocate equipment and available fault calculation.  All changes indicate by DELT-2 on the plans.  Approved plans submitted for reference only.  Plan check for power.*****Walmart remodel - interior gut and installation of new service gear, panels, ckts, equipment, and lighting.  P/C is for Power and Energy.  Variance for Fire Alarm Separation may need to be filed.  FINALS FEES SHOULD BE VERIFIED PRIOR TO PERMIT ISSUANCE.********Click on  ""Application Comment"" for DWP Isc update."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56510	19041-10001-14105	10250 W SANTA MONICA BLVD 2360	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	01/27/2020 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK ONLY. DELTA 4 CHANGES TO AN APPROVED SET. ADDITION OF LT-90 FIXTURES AND INCREASE THE NUMBER OF TRACK LIGHTS WITH CHANGES TO THE CURRRENT LIMITERS. SCOPE ALSO INCLUDES UPATED LOADS. TOTAL SQUARE FOOTAGE: 3,367 SQ FT  *ORIGINAL PLAN IS ATTACHED FOR REFERENCEORIGINAL SCOPE: Full PC for First T.I. (First time tenant). space is served by 200A,480V/277, 3PH,4wire. Area scope 3,367SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56511	15041-20000-38572	20641 W SATICOY ST	91306	3	186B109   237	2108025035	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.20846	-118.58324	PV system.Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. (30) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56512	15041-20000-37871	13441 W VOSE ST	91405	2	183B157   330	2328017024	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	12/14/2015 12:00:00 AM	ADDRESS	34.1986	-118.42614	PV1, roof mounted solar panel, 6.8kW(1) inverter: SE6000A-USpower optimizer: Solar Edge P300(24) modules: SW285 Mono SilverStandard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56513	12041-10000-24819	7065-7065 1/2 W SUNSET BLVD	90028	4	147B181   582	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.09813	-118.34362	CONVERTING AN EXISTING COMMERCIAL SPACES TO A NEW BAR (7065 1/2) AND RETAIL SPACE (7065).  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56514	17041-20000-23180	5360 N DON PIO DR	91364	3	171B105   118	2168026092	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	08/12/2017 12:00:00 AM	ADDRESS	34.16741	-118.60405	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (17) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56515	15041-10000-22499	21601 W VICTORY BLVD	91303	3	180B105    75	2139001009	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.18827	-118.59992	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 38089.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56516	17041-20002-46640	6020 N MELVIN AVE	91356	3	177B117   614	2153028029	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Issued	02/06/2019 12:00:00 AM	ADDRESS	34.17999	-118.55979	02-06-2019 Changes to an approved set of plan, changes include to central inverter system, New PV system size: 15.84KW DC, 13.46KW AC with 48 PV Modules and 2 inverters(7.6KW), 125 A Panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56517	18041-10000-08345	19400 S HARBORGATE WAY #B	90501	15	057B193   127	7351003011	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	33.85402	-118.30332	PC FOR ENERGY ONLY TO AN OFFICE BUILDINGS TENANT IMPROVEMENT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE TO A PORTION OF BUILDING B. TOTAL SQ. FT. 3525.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56518	17041-20001-37699	13337 W ALMETZ ST	91342	7	231B157   156	2582017032	RS-1	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	34.3276	-118.42322	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56519	14041-10000-34264	410 N LA CIENEGA BLVD	90048	5	138B173    27	5514001011	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.07843	-118.37638	Full plan check for office T.I  in a 2-story building including new 800-Amp service upgrade	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56520	12041-10000-17597	700 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM			PC Approved	07/27/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	TILT 24 AND 6 CKTS,  FOR B GRILL AT LAX FOR TERMINAL 7. SPACES 7 J	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56521	14041-20000-12150	16830 W SAN FERNANDO MISSION BLVD	91344	12	210B133   998	2683028038	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Expired	05/31/2016 12:00:00 AM	ADDRESS	34.27181	-118.49871	PC FOR T24 ENERGY ONLY. NEW 2 NEW SIGNS. INTERNALLY ILLUMINATED W/ LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56522	16041-30000-10909	2151 S AVENUE OF THE STARS 1-375	90067	5	132B161   193	4315019006	R4-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.05439	-118.41225	Plan check for power only.  Install 12 VFD (9 @ 40 amps each + 2 @ 27 amps, + 1 @ 3 amps) and replace 2 chillers (340 amps each).  Replace 9 pumps (30 HP), relocate 2 cooling towers (20 HP), and instal new EF (1.5 HP).  New 5 HP sperator and new 3 kVA transformer as well.  Work is being done in basement of a highrise hotel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56523	19041-10000-28264	8110 N WOODMAN AVE	91402	6	189B157    55	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.21819	-118.43077	T-24 PLAN CHECK FOR TI/REMODEL OF EXISTING PHARMACY AT KAISER PERMANENTE NON-OSHPD BLDG. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. NO ALTERATION TO EXAM ROOMS. TOTAL AFFECTED AREA IS 282 SQ.FTB#19016-10000-14599	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56524	17041-20000-41459	155 S BARRINGTON PL	90049	11	135B145   552	4401006018	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.06545	-118.4691	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56525	16041-10001-34579	8425 N SEPULVEDA BLVD	91343	6	192B145   296	2654027007	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.22371	-118.46799	PLAN CHECK FOR POWER ONLY. THIS IS POWER FOR TEMPORARY SALES ARE AND POWER FOR FUTURE TRAILER CONNECTION. TRAILER INTERIOR STATE APPROVED NO INTERNAL PC REQUIRED. LOAD IS GIVEN AS MAXIMUM CONSUMED. ENERGY PLAN CHECK UNDER MASTER. THIS IS POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56526	17041-10000-38775	15232 W FOOTHILL BLVD # 122	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.32292	-118.46695	SFD ROOF-MOUNTED 2.4KW 10 MODULES/ENPHASE MICROINVERTERS PHOTOVOLTAIC SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56527	14041-10000-01544	127 E 9TH ST	90014	14	126A209    39	5145014002	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	PIN	34.04111679	-118.25410856	REPLACING F.A.PANEL, IT MUST MTCH AND BE COMPATIBLE WITH PRESENT DEVICES. ONE NEW DEVICE. HIGH RISE 12 FLOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56528	13041-10000-17335	3850 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Info Complete	08/07/2013 12:00:00 AM	ADDRESS	34.07049	-118.19866	Plan check power and energy for 6-story parking structure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56529	17041-20000-04887	449 S BROADWAY	90013	14	129A211    56	5149026001	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.04848	-118.25056	Plan check for energy only. New outdoor facade lighting for existing building. 4,430sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56530	11041-10001-20648	1049-1057 E ELKGROVE AVE BLDG 38	90291	11	111B145   504	4243003043	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/23/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.00181	-118.4592	LINCOLN PLAZA APARTMENT BUILDING PROJECT((((((((((((((((((((((((  7-23-14    Addition of 3 E.V chargers M.Z. )))))))))))))))))))))))	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56531	12041-10000-20934	10250 W SANTA MONICA BLVD FC-10	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	"NEW ""WHICH WICH"" RESTAURANT IN SAPCE # FC-10. PLAN CHECK FOR POWER & ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56532	19041-20001-28652	9307 N TAMARACK AVE pv1	91352	6	198B165   172	2629012023	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	34.23802	-118.3973	expeditepv1install roof  mounted pv system sized 19.4KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56533	17041-20000-20128	7809 N FAUST AVE	91304	12	189B097   888	2013028021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	08/26/2017 12:00:00 AM	ADDRESS	34.21222	-118.62065	Plan check for solar pv system, roof-mounted on SFD.10.4kW ungrounded system. (28) 300W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56534	13041-10000-35628	845 N FULLER AVE 1-9	90046	5	141B181    50	5526006010	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.08659	-118.35007	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR 9 UNITS 3-STORY APT OVER BASEMENT. 1 FACP, 1 ANNUNCIATOR AND 61 DEVICES (EXCLUDING RELAY/CONTROL MODULES).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56535	15041-10000-13056	2200 W OLYMPIC BLVD	90006	1	130-5A201 159	5136014025	C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM			PC Approved	04/30/2015 12:00:00 AM	ADDRESS	34.05198	-118.28133	"Energy plan plan check for a tear-down and rebuild building (Office Bldg) , orginal pemit is under #12041-10000-15035 and the permit of this application is already paid under permit # 13041-10000-35459. This application is for PLAN CHECK ONLY,  (((""Phase 2"" of a motel remodel with a tear-down and rebuild of a builiding.  Two new 200A panels, loads, circuits.  Full plan check for Power and Energy requested by applicant.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56536	15041-10000-31629	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Closed	11/30/2017 12:00:00 AM	ADDRESS	34.0631	-118.36086	Fire Alarm System. Installing 1 new Fire alarm panel, 1 new communication panel, and 33 fire alarm devices. Scope of work is being done in a new commercial 5 story building (Interim).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56537	14041-10001-25152	355 E 1ST ST	90012	14	129A215    13	5161012903	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM			PC Info Complete	06/25/2015 12:00:00 AM	ADDRESS	34.04958	-118.23946	PC FOR T24. SUPLEMENTAL TO AN APPROVED SET OF PLAN. ADDING ONE NEW PANEL AND REVISIONS TO T24 ENERGY CALCS.CHANGES NOTED AND CLAUDED BY #1. (Fees paid under master permit 14041-10001-25152)<<<<Plan check for title 24 only; new load and equipment have been added on the plan and the load does not exceed 400 amps.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56538	19041-10000-19581	1133 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	08/30/2021 12:00:00 AM		Permit Finaled	11/15/2022 12:00:00 AM	ADDRESS	34.03014	-118.2206	(((((((PERMIT FEE IS $0.0 IN ACCORDANCE WITH AB1414PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 666 MODULES (Q-PEAK 390), 786 OPTIMIZERS (P850 ), 2 INVERTERS ( SE 99.9K). SYSTEM SIZE IS 199.8KWac AND 259.74KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56539	18041-10000-37002	2730 E 12TH ST	90023	14	120A221   172	5169009017	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.02146	-118.21931	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56540	17041-10000-04741	2580 W OLYMPIC BLVD	90006	1	129B197   330	5076008018	C2-2D	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.05219	-118.28726	NEW SANDWICH SHOP AND OFFICE. INCLUDES NEW 600A 120/240 MAIN SERVICE FEEDING THREE STRUCTURES SHARING THE SAME METER, ROOF AND PATIO. PC FOR POWER AND ENERGY. TOTAL AREA IS 23812SQFT. ALL THREE BUILDINGS UNDER THE SAME BUILDING PLAN. BUILDING PERMIT 16010-10000-04748.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56541	18041-20001-22678	9401 N DE SOTO AVE A	91311	12	198B109    69	2746008007	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.24091	-118.58876	Plan check for Title 24 Energy only in existing building T.I. in bathrooms and offices. Total area: 2073 sq ft.  B#18016-10000-16004Permit pulled under Application number 18041-20000-22678	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56542	15041-20000-32309	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for power and energy for T.I. clen room renovation. Total area phase 2 of 3: 16,195 sqft. Newly connected load: more than 400A. Note: refer to Building permit # 15016-20000-20385	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56543	15041-10000-21841	1033 N COLE AVE	90038	13	144B185   841	5533014901	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM			PC Info Complete	09/23/2015 12:00:00 AM	ADDRESS	34.08983	-118.33006	Full plan check for a LADWP one story customer service center and community center. Main scope includes (1) 600-Amp service, (8) panels, (9) equipment, (87) circuits, and total 17390-SQ feet for T-24. Note, building permit is approved in 2010. PERMIT WILL BE PULLED UNDER INSPECTION ONLY. Reference application: 10041-10000-25222,...... and 13041-10000-34371Plan is resubmitted due to expiration and lost plans from 2010 and 2013.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56544	19041-10000-20515	4636 S LINCOLN BLVD	90292	11	105B153   124	4224014023	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Issued	05/31/2019 12:00:00 AM	ADDRESS	33.98239	-118.44062	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56545	13041-10000-25177	1518 W 15TH ST	90732	15	012B193   258	7560024016	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	33.73078	-118.3106	PV1. ROOF MOUNTED SOLAR ARRAY. ENPHASE 215 MICRO INVERTERS. 30 MODULES. SYSTEM SIZE: 7.5 KW DC. 1 STORY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56546	18041-20002-30381	19520 W NORDHOFF ST #4	91324	12	195B117    12	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.23378	-118.55808	02-12-2019 Changes to an approved set of plan, Changes include revised circuit to use normal lighting in the area to supple unit equipment and exit signs. Changes apply to delta 3 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56547	18041-10000-13319	15260 W VENTURA BLVD	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.15356	-118.4658	TI IN AN EXISTING OFFICE SPACE ON THE 22ND FLOOR IN SUITE # 2250.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56548	10041-10000-05058	10942 W WEYBURN AVE	90024	5	135B149   601	4363018020	C4-2D-O	West Los Angeles	Westwood			2652.02	Electrical	Electrical	Commercial			03/19/2010 12:00:00 AM			PC Info Complete	04/07/2010 12:00:00 AM	ADDRESS	34.06239	-118.44657	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR TENANT IMPROVEMENT TO (E) YOGURT SHOP STORE. OUTDOOR LIGHTS ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56549	12041-20000-09890	3041 N DONA NENITA PL	91604	2	156B173   127	2380024008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.12652	-118.37775	"Solar power system for single family dwelling. 9.12 kW DC.""COMPLY WITH DEPARTMENT ORDER effective date12/10/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56550	18041-10000-39115	2049 S CENTURY PARK EAST 20TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. OFFICE SPACE, SUPPORT ROOMS, CONFERENCE ROOMS, NON-STRUCTURAL. 22198 SQFT. HIGH RISE.  SUITE 2000, 20TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56551	19041-10000-13421	617 W 7TH ST # 1000	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.04779	-118.2571	ENCLOSING OPEN OFFICE SPACE -NEW CONFERENCE ROOM STORAGE SPACEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56552	19041-20002-31326	23410 W BESSEMER ST	91367	3	177B093   614	2035004030	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM			PC Approved	09/30/2019 12:00:00 AM	ADDRESS	34.18012	-118.63771	PV1. INSTALL 9.72 KW DC ROOFMOUNTED SYSTEM WITH (27) AC MODULES AND (1) SONNEN BATTERY SYSTEM ON EXISTING 200 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56553	17041-10000-23258	4876 W ADAMS BLVD	90016	10	123B181  1043	5057013011	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.03238	-118.34699	Title 24 plan check.  Replace HID fixtures with new LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56554	17041-10002-01514	13540-13546 W DESMOND ST	91331	7	210B157    70	2523005007	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM			PC Approved	09/06/2017 12:00:00 AM	ADDRESS	34.27544	-118.42731	Changes to permitted set of plans: 150KVA TRANSFORMERS ARE REPLACED WITH 75KVA TRANSFORMERS. PRIMARY AND SECONDARY CONDUCTORS ARE ALSO DECREASED IN SIZE PER CODE REQUIREMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56555	14041-10000-10018	121 N CLARK DR 1-19	90048	5	138B169   304	4335001019	R3-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Public Safety Only			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.07588	-118.38507	NEW FIRE WARNING SYSTEM FOR 19 UNITS APT BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56556	14041-10000-17721	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Corrections Issued	06/30/2014 12:00:00 AM	ADDRESS	33.94558	-118.4039	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT, CONCOURSE LEVEL LIGHTING. 16916 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56557	17041-10003-15761	3344 S LA CIENEGA BLVD GRND FL	90016	10	120B173   249	5048016026	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.02695	-118.37186	REVISED LIGHTING PLAN TO SHOW INCREASED NUMBER OF UNIT EQUIPMENT FOR EGRESS ILLUMINATION . COMPLIANCE FORMS WERE REVISED((((((((((PC FOR ENERGY ONLY. TI. CONNECTED LOAD < 400 AMP. TOTAL AREA 5665 SQ FT.B # 17016-10000-11668	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56558	18041-10000-27137	8526 N INTERNATIONAL AVE	91304	3	192B105   109	2779022052	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Apartment			07/19/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.22533	-118.59931	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES . T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56559	17041-10000-19709	1011 S FIGUEROA ST 4TH FLR	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Info Complete	06/12/2017 12:00:00 AM	ADDRESS	34.04476	-118.26452	TI FOR OFFICE SPACE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56560	15041-20000-30693	741 S SOTO ST	90023	14	124-5A221 254	5183027041	C1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.03475	-118.21569	CONSTRUCT A NEW RESTAURANT BUILDING. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56561	12041-20000-25620	6501 N VAN NUYS BLVD Ground flr	91411	6	180B149   596	2236015004	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02, 1281.00	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	12/26/2012 12:00:00 AM	PIN	34.18884506	-118.44926172	TENANT IMPROVEMENT TO PORTION OF EXISTING OFFICE SPACE ON GROUND FLOOR (AREA OF WORK: 11,651 sq ft): NEW 1-HR RATED CORRIDOR, NON-BEARING PARTITIONS FOR PRIVATE OFFICES, NEW SUSPENDED CEILIGN, FINISHES AND MILLWORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56562	13041-10001-22948	10239 N HELENDALE AVE	91042	7	204A197   104	2558031004	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.25529	-118.29648	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.15 KW USING 10 MODULES. ENPHASE MICROINVERTER. NONSTANDARD PLAN. PC REQUIRED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56563	19041-20001-34253	4404 S GRAND VIEW BLVD	90066	11	108B157   255	4232020019	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			PC Approved	11/20/2019 12:00:00 AM	ADDRESS	33.99476	-118.42201	PV1 EXPEDITED PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.16 KW. SCOPE OF WORK CONSISTS OF (31) PV MODULES WITH MICRO INVERTERS, (2) BATTERY 27 KWH SYSTEM, AND A NEW PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56564	10041-10000-09460	1041 S TIVERTON AVE	90024	5	132B153   137	4363021800	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	11/01/2010 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	34.06085	-118.44328	TI IN AN EXISTING COMMERCIAL BUILDING FOR THE NEW AC UNITS. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56565	17041-10000-05144	11414 S TOWNE AVE	90061	15	087A207   321	6083006027	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	33.93058	-118.2663	Plan check for PV1 roof mounted system. System size: 2.15kWac with 10 modules and 10 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56566	16041-20001-04880	8623 N BURNET AVE	91343	6	192B145     7	2654041***	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Apartment			02/11/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.22692	-118.46345	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. PV system is for Unit 1 of a 6-unit apartment building. System size is 3 kWac and consists of (1) inverter, (6) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56567	17041-20000-41998	8521 N FALLBROOK AVE SUITE #300	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.22368	-118.62797	Change of use from office space to dental lab.  Plan check for power and energy.Building permit under 17016-10000-33693	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56568	13041-10000-26519	8311 N HASKELL AVE	91343	12	192B141   454	2673016064	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.22171	-118.47663	FACU/IPGSM upgrade for existing fire alarm system in retail building.  Addition of 4 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56569	17041-10000-36293	1200 W 7TH ST 2nd Floor	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Issued	12/05/2017 12:00:00 AM	ADDRESS	34.05136	-118.26616	TI TO THE ENTIRE 2ND FLOOR OF A HIGH RISE BUILDING. TOTAL CONNECTED LOAD IS >400A, SQ. FT. 40595.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56570	17041-10000-35533	1726 N NORTH SPRING ST	90012	1	136-5A219  47	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	12/13/2019 12:00:00 AM		Issued	12/13/2019 12:00:00 AM	ADDRESS	34.06983	-118.2261	PC for power and energy for new service to two buildings C and D. Installing new 4000A 120/208V service in new electrical room, new outdoor lights, conduit runs only to other buildings and two subpanels. Building# 17010-30000-03758. Total area is  65679sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56571	14041-20000-21578	12968 W MACNEIL ST	91342	7	219B161    62	2525022029	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.30071	-118.41544	PV1 SFD. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 14 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56572	13041-10000-26223	4943 S MCCONNELL AVE STE D-K	90066	11	105B157   596	4221031004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	ADDRESS	33.98268	-118.42352	TITLE-24 ; TI TO EXISTING OFFICES & RESTROOMS FOR SUITES D - K, IN A SINGLE STORY BUILDING. TOTAL AREA IS 2939 SF. APPLICATION IS ASSOCIATED WITH PLAN CHECK AND PERMIT. EXISTING PERMIT FOR HANDICAP RESTROOMS WAS ALREADY PULLED UNDER 13041-30000-20964 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56573	17041-10000-13513	933 W 253RD ST	90710	15	036B197   434	7413018025	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2944.10	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Issued	04/25/2017 12:00:00 AM	ADDRESS	33.79482	-118.29204	Plan check for new Fire alarm system commercial Total Fire alarm devices: 14  and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56574	13041-10000-30883	22443 W HAYNES ST	91307	12	180B101   425	2038033017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Expired	01/08/2016 12:00:00 AM	ADDRESS	34.18981	-118.61625	PV1, Install 3.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 13 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56575	14041-20000-32600	2045 W 70TH ST	90047	8	102B189   850	6016029011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Expired	12/16/2016 12:00:00 AM	ADDRESS	33.97634	-118.31496	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system.28 255W pv modules across 4 strings (7+7+7+7).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56576	12041-20000-00578	16005 W SHERMAN WAY	91406	6	183B141    86	2206035033	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	02/16/2012 12:00:00 AM		Issued	02/16/2012 12:00:00 AM	ADDRESS	34.20138	-118.48171	Replace existing 400 ampere single phase and three phase 120/240 volt services with new combined 800 ampere 120/240 three phase 4 wire service.   Reconnect existing three phase feeders.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56577	14041-10000-23948	3323 S CLUB DR	90064	5	123B165   761	4316025013	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.03234	-118.40276	INSTALL 10.965 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(43) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGED SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56578	14041-20000-35785	16619 W BASSETT ST	91406	6	183B137   352	2225007004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.19585	-118.49519	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.6kW. Ungrounded system.12  327W pv modules across two strings (8+4).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56579	11041-20000-01500	13200 W OSBORNE ST	91331	6	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.20	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.2458	-118.42068	T.I. for Autozone.  Install general/emergency lighting.  Plan for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56580	18041-10000-31619	6600 N TOPANGA CANYON BLVD #1084B	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR ENERGY ONLY FOR - T.I. FOR EXISTING RETAIL SPACE WITHIN MALL (MONT BLANC). - TOTAL AFFECTED AREA = 1830 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56581	19041-20001-39606	16443 W BRYANT ST	91343	12	195B137   874	2689028017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	34.22761	-118.49083	Revision to approved online permit plan.  Inverter changed from 5 kW to 6 kW model and miscellaneous revisions to address new rating.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56582	12041-20000-16030	15231 W LA CRUZ DR	90272	11	129B125   771	4412002018	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM			PC Approved	07/11/2012 12:00:00 AM	ADDRESS	34.04579	-118.52507	energy plan check retail bakery	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56583	15041-20001-13495	1001 S BROADWAY	90015	14	126A209    61	5139013022	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM			PC Approved	06/24/2015 12:00:00 AM	ADDRESS	34.04086	-118.25782	Power plan check only.  Total area = 1,084 sq. ft.  T.I. to existing low rise commercial space.  Change of use from retail to restaraunt.  131 A new connected load.  Plan check at request of inspector.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56584	15041-20000-38546	5353 N DEL MORENO DR	91364	3	171B113    53	2166035032	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.16815	-118.57608	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (30) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56585	16041-30000-23400	20116 W STARE ST	91311	3	204B113   597	2741012022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.25264	-118.57178	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56586	16041-20000-19820	414 S CLOVERDALE AVE 1-58	90036	4	135B181   423	5508005029	[Q]R4-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.06644	-118.34603	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE : 34.0 KW with 123 Modules and 3 invertersNote: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56587	14041-10000-25445	1327 S HILL ST	90015	14	124-5A207  37	5134025010	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.03703	-118.26296	PLANCHECK FOR T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 6156 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56588	19041-10000-15494	5552 W CENTURY BLVD	90045	11	090B173   137	4129029022	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	33.94522	-118.37789	PC FOR ENERGY ONLY INTERIOR REMODEL OF EXISTING CONVENIENCE STORE, ADDITION OF NEW METAL CANOPY AT STORE FRONT. SCOPE AREA 1,678SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56589	11041-20001-15026	18001-18137 W CHATSWORTH ST BLDG A	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM			PC Approved	12/08/2011 12:00:00 AM	ADDRESS	34.26501	-118.52523	Modidfication to an approved set of plans.  The modifications all occur in space 15. The modifications are the removal of the light fixtures in the space so that the tenant can do their own lighting.  Changes were made to the lighting plan, title 24 sheets, panel shedule and single line sheet.  All changes are denoted by DELTA 8A.  <<<<<<PLAN CHECK POWER AND ENERGY FOR VANILLA SHELL RETAIL/RESTAURANT SPACES TO EXISTING SERVICE AND BUILDING.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56590	11041-10000-20635	1601-1613 S PENMAR AVE BLDG 29	90291	11	111B149   204	4243001042	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.00337	-118.458	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56591	19041-20000-19306	110 S FAIRFAX AVE a-17	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.07371	-118.36119	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56592	13041-10000-21156	12652 W VILLAGE LANE bldg #12	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #12	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56593	18041-20000-27755	3324 N BONNIE HILL DR	90068	4	159B177   743	2427002015	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2018 12:00:00 AM			PC Info Complete	08/28/2018 12:00:00 AM	PIN	34.12821085	-118.35598321	Plan check for PV roof and ground mount system . System size: 31.4kW AC with 92 modules and 3 inverters(10KW, 10KW, 11.4KW) connected to MSP 400AFees $0.00 Due to California Senate Bill 1222 and Assembly Bill 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56594	12041-10000-08747	18441 W VENTURA BLVD	91356	3	171B125    19	2160008031	C2-1, C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Approved	04/17/2012 12:00:00 AM	ADDRESS	34.16839	-118.5346	inside an existing CVS pharmacy, remodel the pharmacy area- new luminaires and circuits. EMS is existingPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56595	14041-20000-04227	8112 N CLEMENS AVE	91304	12	189B093    40	2020021022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Expired	04/28/2016 12:00:00 AM	ADDRESS	34.21793	-118.63765	Roof mounted PV system with Optimizers.  System size is 9KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56596	17041-10001-18314	2002 W SLAUSON AVE	90047	8	105B189    20	6001001900	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	33.98891	-118.31398	Expedite fees only.       Installation of new solar PV system on two new carports and one new office building roof.  260 modules connected to 5 new inverters which feed 200 amp 208/120 volt solar only load center.  Supply side tap connection.  Total system size = 56 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56597	15041-20000-19728	22963 W CASS AVE	91364	3	168B097   552	2074010036	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.15551	-118.62106	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (49) modules, (49) power optimizers, and (1) load center.Note: Permit fees $0.00 due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56598	16041-10005-26899	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.32381	-118.49103	PC FOR TITLE 24 ENERGY ONLY FOR GIFT SHOP  AREA. THIS AREA PREVIOUSLY REMOVED FROM PLAN  ON 10003 SUPP. SCOPE OF WORK INCLUDES LIGHT FIXTURES AND CONTROLS ONLY. PERMIT UNDER MASTER THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56599	16041-20000-07538	120 S RENO ST	90057	13	138A201   373	5155004025	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.07077	-118.28154	$0 permit fee is due to State Senate Bill SB 1222PV2. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM 2 SIZE: 61.9 KW.TOTAL SYSTEM SIZE: 234 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56600	15041-10001-31374	4181 S MARCASEL AVE	90066	11	111B157   800	4233015005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	33.99896	-118.42182	1/28/2016APPROVAL OF PLANS PER INSPECTOR. PC ONLY, ORIGINAL FEES WERE PAID UNDER MASTER APLLICATION. (((PV1. NEW ROOF-MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 7.6 KW. (31) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-FRONIUS #PRIMO 7.6)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56601	11041-10000-18480	13455 W MAXELLA AVE #206-02	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM	09/07/2011 12:00:00 AM		Permit Finaled	09/15/2011 12:00:00 AM	ADDRESS	33.9867	-118.44159	T.I. TO EXISTING RETAIL SPACE.  (STE. 206)  PLAN CHECK ONLY FOR ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56602	11041-20001-04398	257 N TRANQUILLO ROAD	90272	11	126B117    62	4416016069	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.04442	-118.56227	Modification to an approved set of plans.  Change from 2 inverters to 1 inverter and add AC disconnect inside dwelling unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56603	18041-20000-09463	22331 W MULHOLLAND DR	91364	3	165B101   218	2076024006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.14927	-118.61251	Plan check for a PV1 roof-mounted PV system. System size is 8.795 kWac/12.2 kWdc and consists of (1) inverter and (40) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56604	11041-10001-20344	19481 S HARBORGATE WAY	90501	15	057B193    21	7351021016	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM			PC Approved	04/11/2012 12:00:00 AM	ADDRESS	33.85326	-118.30372	Revision to approved plans. Reduce scope of work from original plans. Changes to T24 calculations and lighting plan. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56605	16041-20000-19003	3347 W SAN FERNANDO ROAD	90065	13	153B209   103	5458006002	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.11858	-118.24925	$0 permit fee is due to State Senate Bill SB-1222PV2.  Install 36 kW rooftop mounted PV system.  (126) 285 W modules with (1) 30kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56606	19041-20000-53344	5758 N CAMELLIA AVE	91601	2	174B169   317	2338023005	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	02/01/2022 12:00:00 AM	ADDRESS	34.17551	-118.3821	NEW FIRE ALARM SYSTEM IN A 4 STORY APARTMENT BULDING WITH 82 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56607	18041-20000-23126	3438 W SUNSET BLVD	90026	13	144A203   261	5427026007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.08833	-118.27648	Plan check for Title 24 only in existing space. new lighting. Total area: 960 sq ft. B#18016-10000-11758B#18016-20001-11758	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56608	11041-10000-26525	9851 N TUNNEY AVE	91324	12	201B117   123	2761034005	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/18/2012 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.2496	-118.55807	New 9.69KW, rooftop, Photovoltaic system for a single family residence.  Two inverters with 73 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56609	17041-10001-07840	916 N WESTERN AVE 130	90029	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM			PC Approved	04/21/2017 12:00:00 AM	ADDRESS	34.08674	-118.30896	T-24 PC ONLY FOR A T.I. ELECTRICAL FOR SALAD BAR RESTAURANT. FEES ARE PAID UNDER THE MASTER APPLICATION. BUILDING PERMIT#16016-100000-28391	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56610	16041-10002-31733	269 S SAN PEDRO ST	90012	14	129A213   450	5161025***	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Info Complete	05/02/2017 12:00:00 AM	ADDRESS	34.0477	-118.2427	PC FOR CHANGES TO APPROVED SET. EXRAY MACHINE AND TRANSFORMER ARE NEW TO SCOPE. PC AND PERMIT FOR ADDITIONAL SCOPE OF WORK. DELTA 1 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56611	16041-10000-17687	8274 N SUNLAND BLVD	91352	2	192B173   562	2407024039	[Q]C2-1VL-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.22101	-118.3672	PLAN CHECK FOR POWER AND  ENERGY .NEW SINGLE-STORY RESTAURANT BUILDING WITH A NEW 600 A SERVICE. TOTAL AREA FOR THE SCOPE IS 32,795 SQ FEET (IN/OUTDOOR).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56612	17041-20001-41228	10033 N CASABA AVE	91311	12	204B113   579	2741019025	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.25281	-118.57618	expeditepv1install roof mounted pv system sized 12.6kw intercvonnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56613	15041-20000-00068	5670 W WILSHIRE BLVD SUITE 820--850	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 5892.  SCOPE OF WORK TO BE DONE ON THE EIGTH FLOOR SUITE 850 AND 820	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56614	10041-20000-11316	10960 W WILSHIRE BLVD 5TH FLR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Expired	12/11/2015 12:00:00 AM	ADDRESS	34.058	-118.44597	PLAN CHECK T-24 ENERGY GENERAL/EMERGENCY LIGHTING FOR OFFICE SPACE TI ON 5TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56615	10041-10000-12857	1400 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 404	5173029909	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	06/08/2011 12:00:00 AM	ADDRESS	34.05032	-118.22517	New PV System on commerical building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56616	12041-20000-15338	16500 W SHERMAN WAY	91406	6	183B137    75	2225004049	[Q]C2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.20093	-118.49259	T.I. to existing building space A18.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56617	16041-20000-35662	453 S KENMORE AVE	90020	10	135B197   728	5502013063	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Apartment			10/07/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.06567	-118.29698	Plan check fire alarm system for 7 story apartment building. 1 FACP. 287 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56618	10041-20000-13895	16909 W PARTHENIA ST #202-205	91343	12	195B133   421	2688041013	CR-1VL, P-1VL	North Valley	Northridge			1173.02	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM			PC Info Complete	07/20/2010 12:00:00 AM	ADDRESS	34.22864	-118.50078	Plan check T-24 Energy (general/emergency) lighting for office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56619	15041-10001-25785	8640 S VERMONT AVE	90044	8	097-5A199 334	6038010018	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	33.95922	-118.29137	12/13/16Changes to an approved set of plans. All changes are clouded under delta 3. Changes include replacing/removing lighting fixtures on the lighting floor plans, adding bug eyes, and revising title 24 calculations. Changes to reflect what is on the field. Note: Permit is paid under PCIS#15041-10000-25785(((((((FULL PC FOR A NEW RETAIL BLDG. 4 NEW TENANTS (1) STORY BLDG, INDOOR AND OUTDOOR LIGHTING  TOTAL SQ FT = 8175.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56620	19041-10000-52656	15043 W GILMORE ST	91411	6	180B145   675	2235019047	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.18772	-118.46097	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 11  (PANASONIC 330W) MODULES, 11  (ENPHASE IQ7X) MICROINVERTERS, 1 TESLA  POWERWALL, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL.  SYSTEM SIZE: 3.63KW DC, 3.46KW AC. EV OUTLET UNDER SEPERATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56621	17041-10000-24614	3525 W 8TH ST	90005	10	132B193   573	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM			Reviewed by Supervisor	10/04/2017 12:00:00 AM	ADDRESS	34.05782	-118.30714	PC FOR FA FOR A NEW CONSTRUCTION-SEVEN  STORY TYPE III-A 367 UNIT APARTMENT BUILDING OVER TWO LEVELS TYPE IA RETAIL/COMMERCIAL/PARKING OVER THREE LEVELSTOTAL DEVICE COUNT 1624 WITH 27 PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56622	18041-10000-08601	1418 N BEVERLY DR	90210	4	147B161   307	4355016032	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	09/01/2018 12:00:00 AM	ADDRESS	34.09646	-118.41458	((Zero permit fee due per Senate Bill 1222))  PC FOR ROOF MOUNTED PV ON SFD.   SYSTEM SIZE 12.21KWDC/10KWACSCOPE INCLUDES 37 MODULES WITH OPTIMIZERS AND 2 CENTRAL INVERTERS WITH NEW LOAD CENTER .	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56623	19041-10000-45248	4942 N MAMMOTH AVE	91423	4	168B157    33	2269023026	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.16078	-118.43232	(E-PLAN) NEW PV1 ROOF-MOUNT INSTALLATION TO A SERVICE OF 225 AMPS. INSTALLATION INCLUDES 1 COMBINER BOX, 36 MICRO INVERTERS (Enphase IQ-7-60-2-US), 36 MODULES (LG LG350N1C-V5).  SYSTEM SIZE: 12.6 KW DC; 8.64 KW AC  NOTE: MAIN PANEL UPGRADE WILL BE PULLED ON A SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56624	12041-10001-24819	7065-7065 1/2 W SUNSET BLVD	90028	4	147B181   582	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.09813	-118.34362	CHANGES TO APPROVED SET. ASBUILT-SWAP PANELS.ADD 8 LIGHTS TO BRANCH.CONVERTING AN EXISTING COMMERCIAL SPACES TO A NEW BAR (7065 1/2) AND RETAIL SPACE (7065).  PLAN CHECK FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56625	16041-20000-14121	555 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM			PC Approved	04/22/2016 12:00:00 AM	ADDRESS	34.13776	-118.3584	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,960 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56626	14041-20000-01595	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC FOR T24 ENERGY ONLY FOR SIGN. SLTG FORMS ATTACHED. TOTAL AREA OF SIGN 120 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56627	15041-10001-14904	1050 S GRAND AVE	90015	14	127-5A207 294	5139010013	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.04171	-118.26155	changes to approved set including addition of 2 servise rated disconnects ahead of two fire pump controllers required by DWP. per Mike Packard and M. ZandiPC FOR POWER AND ENERGY. NEW HIGH RISE, MIXED USED BUILDING, WITH 22 STORIES AND 151 UNITS AND 10 TYPES APARTMENTS. TOTAL AREA 38813 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56628	19041-10000-53600	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.05189	-118.25546	T-24 ENERGY PC ONLY. TOTAL AFFECTED AREA 1196sqft. SCOPE OF WORK INCLUDES INSTALLATION OF NEW LIGHTS USING EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56629	15041-20000-07105	436 N LA CIENEGA BLVD	90048	5	141B173  1304	5514001005	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			PC Approved	03/11/2015 12:00:00 AM	ADDRESS	34.07915	-118.37637	PC FOR T24 ENERGY ONLY. NEW/ MODIFIED LIGHTING DESIGN.permit already issused under 15041-10000-04642	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56630	13041-10000-03504	19524 W INGOMAR ST	91335	3	189B117   849	2116010006	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.21191	-118.55897	PV1 Plan check 5.2KW photovoltaic system roof-mount Permit includes service panel upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56631	17041-10001-12235	11766 W WILSHIRE BLVD 17TH FL	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Info Complete	05/04/2017 12:00:00 AM	ADDRESS	34.04804	-118.46227	PLAN CHECK FOR LOST SET OF PLANS.  17TH FLOOR TI, COMMON AREA UPGRADES. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56632	16041-20000-34024	18038 W VALLEY VISTA BLVD	91316	5	168B125   299	2181028021	R1-1	South Valley	Encino - Tarzana	Encino		1397.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.15805	-118.52622	pv1install roof mounted pv system sized 12.7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56633	15041-10000-19449	240 S CHADBOURNE AVE	90049	11	129B137   104	4406020014	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.05272	-118.49066	Power plan check for a new house with a  600-Amp 120/240V single phase service equipment, (4) panels,  (102) circuits and other equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56634	14041-20001-33616	7940 N VAN NUYS BLVD	91402	6	189B149   634	2212028020	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM			PC Approved	03/09/2015 12:00:00 AM	ADDRESS	34.21548	-118.44851	PC FOR NEW 400A METER SECTION. MAKING ROOM FOR FUTURE CHIPOTLE. EXISTING DEMAND READINGS HAVE BEEN PROVIDED BY DWP. PC FOR POWER ONLY. PC ONLY. PERMIT ALREADY ISSUED UNDER MASTER APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56635	15041-10001-42820	701 W EXPOSITION BLVD	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.01842	-118.2857	08-15-2016 Changes to an approved set of plans. Changes include change lighting fixture from 2x4 to 2x2 in vending and seminar room, and remove some of lighting fixtures LN2-2 and LN2-4, and remove scope of work on Third and Fourth Floor Jannitor & Women restroom, and add branch circuits assciated loads. Changes apply to delta 4&5 only. {{{{{{{{{{PC FOR POWER AND ENERGY. 8-STORY BUILDING IN USC CAMPUS. (BUSINESS SCHOOL). T.I FOR BASEMENT THROUGH 4TH FLOOR. ADDITION OF NEW LOADS TO EXISTING PANELS. TOTAL AREA 23439 SQ FT. (FULL PC PAER APPLICANT REQUEST)}}}}}}}}}	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56636	11041-20001-12115	6902 W SANTA MONICA BLVD	90038	4	144B181   478	5532029013	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Info Complete	01/24/2012 12:00:00 AM	ADDRESS	34.09049	-118.34078	revision 1 as built drwaings add 3 a/c remove 2 panels	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56637	15041-10001-33197	1435 W 7TH ST	90732	15	015B193   409	7459001016	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	33.7377	-118.30896	Changes to approved set. Replacing duct detectors for smoke detectors. Changing type of amplifier panel. Note changes in Delta 1  (((INSTALL NEW FA SYSTEM FOR A  two-story temple(assembly Area). 93 DEVICES, ONE FA PANEL AND ONE AMPLIFIER PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56638	15041-10000-40406	865 S FIGUEROA ST 8TH FLOOR	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	T-24, TI IN THE 8TH FLOOR OF AN OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPATCLES. TOTAL SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56639	18041-10000-28722	1400 S ESPERANZA ST	90023	14	118-5A227 286	5191023001	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.01704	-118.20086	PLANCHECK FOR POWER AND ENERGY.  CHANGE OF USE FROM WAREHOUSE TO INDOOR NURSERY( PLANT GROWTH) . BUILDING PERMIT #18016-10000-05342	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56640	15041-20000-17225	14857 W BESSEMER ST #5	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	34.18089	-118.45716	Plan check for Title 24 only for retail T.I. Total area: 2,400 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56641	10041-20000-20030	6300 N CANOGA AVE 13th Floor	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	12/09/2010 12:00:00 AM	ADDRESS	34.18492	-118.59722	T.I. to exist high rise building of New England Life Insurance.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56642	19041-10000-47509	3001 W BEVERLY BLVD	90057	13	138A201   263	5156011009	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Closed	10/24/2023 12:00:00 AM	ADDRESS	34.07165	-118.28136	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56643	19041-10000-40830	7257 W SUNSET BLVD	90046	4	147B181   607	5548010022	C4-1D	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM			Ready to Issue	05/08/2020 12:00:00 AM	ADDRESS	34.09816	-118.3483	Energy plans for new restrooms located in an existing employee break room of a single story building. Scope includes new lighting and equipment with a total lighting area of 637 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56644	16041-20000-17301	20546 W INGOMAR ST	91306	3	189B109   899	2108023013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	34.21184	-118.58138	PV1INSTALL ROOF MOUNTE PV YSTEM  SIZED 6KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56645	13041-10003-01320	2500 S WESTERN AVE	90018	8	123B193   477	5058015005	C2-1, RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM			PC Approved	04/08/2015 12:00:00 AM	ADDRESS	34.03373	-118.30879	(((4/7/2015)))  PLAN CHECK FOR POWER CHANGES TO FEEDERS AND DISTRIBUTION BOARD DBH-7F AND DBH-6F.Plan check for power   Change of feeders from copper to aluminum, miscellaneous new loads, and (2) additional lighting fixtures (minor T24 changes).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56646	19041-10001-13330	216 S LAKE ST	90057	13	135A205    63	5154008019	R3-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM			PC Approved	04/29/2019 12:00:00 AM	ADDRESS	34.0657	-118.27208	EXPEDITE PER APPLICANT REQUEST. (((NEW ROOFTOP SOLAR SYSTEM CONSIST OF 48 AC MODULES (SPR-X22-360-D-AC). SYSTEM SIZE IS 17.28KWac. SCOPE INCLUDES NEW 125A SUBPANEL. MORE THAN 50% CHANGES TO AN APPROVED-PERMITTED SET.  APPROVED SET UNDR 18041-10000-46011.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56647	19041-10000-09090	445 S FIGUEROA ST ste. 2140-2160	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	PLAN CHECK FOR T-24, Tenant improvement work on  Suite 2140, Suite 2160. Scope of work includes new lighting and receptacles. Total  Area = 4345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56648	15041-10001-35449	9857 N RATHBURN AVE	91325	12	201B125    95	2764002001	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM			Reviewed by Supervisor	11/03/2015 12:00:00 AM	ADDRESS	34.24968	-118.53319	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 12.426 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (38) MODULES: SUNPOWER SPR-327-NE-WHT-D(2) INVERTER: POWER-ONE PVI-6000-OUTD-US-A 240>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56649	16041-10000-42448	917 N NORTH MAIN ST	90012	1	133-5A215  35	5409008023	[Q]C2-2-RIO	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	34.06161	-118.23518	PC for energy only. Outdoor title 24. Adding new lighting to parking lots. Total sqft = 24040.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56650	12041-10000-11447	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	09/10/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check of power. New installation distribution boards and baggage handling systems for LAX TBIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56651	17041-10001-41266	1370 N ST ANDREWS PL	90028	13	147A193   175	5544030056	(Q)C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.09641	-118.31076	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE UNDER DELTA 1. CHANGES INCLUDE REMOVING LIGHTING FIXTURES FOR POD A, AND REDUCING POWER CIRCUITS, AND REVISING TITLE 24 CALCULATIONS. B#17010-10000-04088NOTE: PERMIT FEES WILL BE PAID UNDER PCIS# 17041-10000-41266	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56652	14041-10000-19715	907 S SHENANDOAH ST	90035	5	132B169   121	4333012024	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.06063	-118.3816	4 story apartment fire alarm. 50 devices and 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56653	11041-20000-19204	16204 W PARTHENIA ST	91343	12	195B137   957	2689024023	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			09/09/2011 12:00:00 AM	09/09/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.22816	-118.48596	ENERGY PLAN CHECK NAIL SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56654	19041-20000-22480	575 N HANLEY AVE	90049	11	135B137    33	4494019027	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.06992	-118.48616	Plan check for the addition of a battery back-up unit to an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56655	17041-10000-33475	11922 W FOOTHILL BLVD	91342	7	210B165   107	2532012038	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.27524	-118.3962	PC for T24 only for altereration in lighting system for TI. Installing new circuits, equipment and lighting. Load <400A.Total of 3300 sqft.Build# 17016-10000-27114	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56656	19041-20000-52210	649 W 34TH ST	90731	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	02/11/2020 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	34.02191	-118.28195	T24 PLAN CHECKENERGY ONLY,  FOR LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 1450 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56657	16041-20000-12927	22948 W ELKWOOD ST	91304	12	189B097   849	2014022012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.21246	-118.62731	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (40) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56658	12041-10000-25220	8876 N MOORCROFT AVE	91304	12	195B101   112	2004023010	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Expired	12/11/2014 12:00:00 AM	ADDRESS	34.23211	-118.61011	5.88 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56659	14041-10006-29996	616 S NORMANDIE AVE	90005	10	135B197  1114	5502031011	R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			12/14/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.06287	-118.30017	12/14/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 9. CHANGES INCLUDE ADDING A SWITCHBOARD TO DISTRIBUTE POWER FROM THE EMERGENCY GENERATOR TO THE STANDBY AND EMERGENCY SYSTEMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56660	17041-20000-44161	8011 N SEPULVEDA BLVD	91402	6	189B145   332	2654037024	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Apartment			12/08/2017 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	01/13/2021 12:00:00 AM	ADDRESS	34.21607	-118.4664	Plan check for power and energy. Project site is a new 5-story, 32-unit apartment building over 1 level of basement parking garage. Total lighting area = 31,455 sq. ft.Note: Building application has been generated under 17010-20000-03717	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56661	15041-10000-00744	6255 W SUNSET BLVD suite 711	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for Title 24 only. Project is a tenant improvement to an existing suite within an existing high-rise building. Total lighting area = 1,450 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56662	15041-20001-39933	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	10.18.2017 - Plan check for modifications to approved set. Reducing MSA, service disconnect, and DBA to 800A. Removing sewage pump and controls. Changes clouded delta 5.=======Full PC for new warehouse shell only, Scope includes New Xformer, elec.room, house panels and site lighting.2000 MSA, total area: 255,181sq.ft (uncondition+hardscape)((WHSE SHELL))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56663	12041-10001-22239	11350 W VICTORIA AVE	90066	11	114B157    91	4234003040	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.01234	-118.42223	PV1 REVISION TO APPROVED PLANS. REVISE PANEL LAYOUT ON ROOF. INSTALLATION ROOF MOUNTED 4.16KW PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56664	15041-10000-36393	13274 W FIJI WAY 2ND FLR	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	33.97902	-118.43558	T-24, TI TO THE 2ND FLOOR CORRIDOR OF AN (E) OFFICE BUILDING. TOTAL SQ. FT. 571.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56665	19041-10000-34376	827 N VINE ST	90038	13	141B185   150	5533030031	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	06/15/2022 12:00:00 AM	ADDRESS	34.08598	-118.32689	PC FOR A NEW FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES REPLACEMENT OF EXISITNG FIRE ALARM PANEL TO A BIGGER SIZE AND ADDING 421 NEW FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56666	18041-20000-40093	6635 N PETIT AVE	91406	6	180B137   196	2231017028	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.19141	-118.49702	pv1install roof mounted pv system sized 15.23KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56667	13041-20000-22893	11963 W VENTURA BLVD	91604	2	162B169    82	2368006002	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.14366	-118.39247	Change of use from Retail to Nail Salon.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  Per applicant there is no Emergency lighting in the space.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56668	12041-10000-27314	12012 W THERMO ST	90066	11	117B153   526	4248012009	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.0176	-118.43855	MICROINVERTER ENPHASE STANDARD PLAN. ROOF MOUNTED PV1 SOLAR INSTALLATION. SYSTEM SIZE IS: 4.16KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56669	12041-20000-06043	9911 W PICO BLVD #990	90035	5	129B165    65	4330005043	C4-1VL-O	West Los Angeles	West Los Angeles			2690.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.05339	-118.40441	energy plan check # 990	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56670	10041-10000-04390	21747 W ERWIN ST	91367	3	177B105   124	2146029017	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM			PC Approved	03/11/2010 12:00:00 AM	ADDRESS	34.18325	-118.60307	TENANT IMPROVEMENT OF EXISTING BALLET CLASSROOMPLAN CHK FOR TITLE 24 IS REQUESTED BY THE SUBMITTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56671	11041-10000-09913	7621 S FIGUEROA ST	90044	8	099B201   213	6020020027	C2-1VL	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	Apartment			05/16/2011 12:00:00 AM	10/04/2011 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	33.97005	-118.28302	NEW 35 UNIT 4 SORY SENIOR HOUSING WITH PARKING ON THE FIRST FLOOR.  FIRE ALARM TO BE SUBMITTED SEPARATELY.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56672	15041-10000-07183	600 W WORLD WAY SPACE 645	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			PC Info Complete	04/22/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	TI FOR AN EXISTENCE COMMERCIAL SPACE AT LA X TERMINAL 6. ADDING NEW LIGHTING NEW CONTROLS NEW PANELS PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 1938. SCOPE OF WORK TO BE PERFORMED IN SPACE 645.INSPECTION FEES PAID UNDER APPLICATION NUMBER 15041-90000-22964.  THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56673	11041-10000-26974	10329 W PALMS BLVD 1-31	90034	5	120B161   400	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Public Safety Only			12/19/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.02679	-118.40832	INSTALLATION OF A FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING IN IN A MIXED USE  (APTS & RETAIL) BUILDING-	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56674	17041-10000-03442	4600 W ADAMS BLVD	90016	10	123B181  1008	5050003012	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.03238	-118.34069	PC for outdoor title 24. Removing HID fixtures and raplaing them with LED ones. Area: 3825 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56675	16041-10000-13064	2633 S ROBERTSON BLVD	90034	5	126B169  1448	4301006001	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			PC Info Complete	04/14/2016 12:00:00 AM	ADDRESS	34.03779	-118.38871	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. CHANGE OF USE FROM RETAIL TO AN ICE CREAM SHOP. TOTAL AFFECTED AREA IS 589 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56676	17041-20003-41504	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.28583	-118.51165	"01/31/2018 Changes to an approved set of plans. Changes have been made to clarify the type of AC disconnect being installed. AIC rating of OCPDs has been specified.*****Previous Work Description*****SUPPLEMENTAL PERMIT TO ADDRESS TEMPERATURE CORRECTIONS FACTOR. CONDUIT WILL BE RAISED TO 4"" ABOVE THE ROOF TO BOTTOM OF CONDUIT PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.145 KW"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56677	10041-10001-23788	528 S WESTERN AVE	90020	4	135B193   763	5503019015	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	05/24/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.06449	-118.30891	NEW COFFEE SHOP WITH OUTSIDE DINING((((  cHANGES MADE TO PREVIOUSLY APPROVED SET OF PLAN , ADDITION OF 19 CIRCUITS , NEW RECEPTACLES AND CHANGE OF FIXTURES FOR TITLE 24  )))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56678	19041-30000-08866	6080 W CENTER DR Suite 710	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	Plan check for Title 24 only. Project site is part of the 7th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 215 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56679	14041-10000-01415	601 N GRAND AVE 1-302	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural		2071.01	Electrical	Electrical	Apartment			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.06097	-118.2438	REPLACING FIRE ALARM CONTROL PANEL TO AN EXISTING FIRE ALARM SYSTEM. ALSO, ADDING (1) NEW SMOKE DETECTOR. FACP MANUFACTURER : MIRCOM, FX-2003-12XTDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56680	11041-10000-17313	12450 W BURBANK BLVD	91607	2	174B165   776	2347001072	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	34.17197	-118.40477	T.I.  Existing 7-Eleven.  Replacing the existing fixtures with LED fixtures in the retail area only.  Plan check is for energy only..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56681	16041-10000-27256	1653 S ABBOT KINNEY BLVD A	90291	11	108B145  1636	4241036038	(T)(Q)CM-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM			PC Approved	08/02/2016 12:00:00 AM	ADDRESS	33.98939	-118.46274	T-24, PC FOR ENERGY ONLY. TI TO (E) RETAIL SPACE. CHANGE OF USE FROM RETAIL TO TAKE OUT JUICE BAR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1160 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56682	11041-20000-19585	805 N BROOM WAY	90049	11	138B141   476	4494011016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.07169	-118.48477	New roof mounted 5.85KW Photovoltaic system for single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56683	15041-10000-33223	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Closed	01/22/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC for power. Providing temp power for existing panels, addition of 6 temp distribution panel to feed the existing panels. Range of the boards amper is 1000A to 3200A . Original permit  15041-10000-07080.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56684	12041-10000-23832	6225 W CENTURY BLVD	90045	11	090B165     5	4124026005	LAX, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.9457	-118.39456	INSTALL 6 NEW 60KW ELECTRICAL SPACE HEATERS IN THE BALLROOM OF A HOTEL.  EXISTING SERVICE AND PANELS.  (INSPECTOR TO VERIFY THE SIZE OF 8,000 AMP 277/480 SERVICE AND THE TOTAL NUMBER OF 7 FEEDERS WITH A TOTAL OCPD LIMITED TO 4,200 AMPS MAX.).  COMPLY WITH DEPARTMENT ORDER effective date 05/29/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56685	18041-20002-03282	5610 N CAMELLIA AVE	91601	2	174B169   787	2338028019	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			04/03/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	02/03/2021 12:00:00 AM	ADDRESS	34.17257	-118.38211	4/3/2019changes to an approved set of plans.  changes to include new panels and associated circuits, revised unit floor plans.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56686	19041-20000-23996	15030 W BLEDSOE ST	91342	7	222B145    15	2506015016	(T)R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.30963	-118.46019	Plan check for PV roof mounted and energy storage system, PV system size: 9.9 KW  and 1 Tesla 13.5KWh. with 30 PV modules and 1 inverter(7.6KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56687	11041-20000-01964	6404 W WILSHIRE BLVD 5TH-12TH FL	90048	5	135B173   870	5088013022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM			No Progress	02/01/2011 12:00:00 AM	ADDRESS	34.06351	-118.36852	PLAN CHECK ONLY. T24 ENERGY AND EMERGENCY LIGHTING FOR CORRIDOR TI FROM 5TH-12TH FLOOR AND OFFICE AREA ON 12TH FLOOR. EXISTING PERMIT FOR 12TH FLOOR #11041-30000-00918.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56688	18041-10000-37363	4525 W WILSHIRE BLVD STE. 150	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	PC FOR ENERGY ONLY, TENNANT IMPROVEMENT WORK TO AN EXISTING SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUITS TO EXISTING PANELS. TOTAL SQ. FT. 9615.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56689	16041-10000-36988	11320 N MCLENNAN AVE	91344	12	210B133    30	2682026020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.27622	-118.50091	****************************************************************************PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.65KWdc / 11.2KWac.(46)MODULES-REC SOLAR REC275TP(1)INVERTER-NINGBO GINLONG TECHNOLOGIES: SOLIS-3.6-2G-US(1)INVERTER-NINGBO GINLONG TECHNOLOGIES: SOLIS-3.6-2G-US(1)INVERTER-NINGBO GINLONG TECHNOLOGIES: SOLIS-4K-2G-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56690	17041-10000-18436	12501 W CHANDLER BLVD	91607	2	171B165    55	2346011054	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.1688	-118.40569	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56691	14041-10001-11914	5245 W SANTA MONICA BLVD	90029	13	144B193   695	5537009018	[Q]C2-2D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM			PC Approved	01/10/2018 12:00:00 AM	ADDRESS	34.09094	-118.30401	UPDATED SET OF PLANS TO INCLUDE CORRECT AVAILABLE SHORT CIRCUIT AT POINT OF  SERVICE AND AT PANELBOARDS AND SWITCHES AND SHOW THAT A REDUCED BUS REPLACE CONDUCTOR SUPPLYING HOUSE DISTRIBUTION BOARD, PLANS ARE AS BUILT .(((((((PC power and energy for a new 52 units, residential/commercial building. modification for early start conduit only permit has been filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56692	16041-10002-45793	7157 WORLD WAY MSC-M/V	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check for a lost set of plan (16041-10001-45793). Permit shall be under the lost application. Applicant request Mehdi as the plan checker.(((CHANGES TO APPROVED SET OF PLANS PLAN CHECK FOR POWER AND ENERGY - SCOPE INCLUDES ADDITION OF NEW PANELS AND CIRCUITS WITHIN MULTIPLE PANELS, AS WELL AS RELOCATION OF LIGHTING (PHOTOMETRICS)FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES  Adding new lighting, medium voltage power, and emergency power to LAX MSC utility equipment room Total area: 5285. b#16014-10000-02498)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56693	15041-10000-22464	15233 W VENTURA BLVD GRND FLR-#100	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.1538	-118.46502	TI TO AN EXISITNG COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. SCOPE OF WORK IN GROUND LEVEL TOTAL SQUARE FOOTAGE 11335	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56694	18041-10000-33182	3222 S COMPTON AVE	90011	9	115-5A211  60	5117007004	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.01211	-118.24869	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56695	16041-10000-11121	6300 W WILSHIRE BLVD #830	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Info Complete	03/31/2016 12:00:00 AM	ADDRESS	34.06319	-118.36591	T-24, PC FOR ENERYG ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON SUITE 830. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING OFFICE SPACE ON THE 8TH FLOOR. TOTAL AFFECTED AREA IS 1809 SQ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56696	14041-20000-03224	2749 W LOMPOC ST	90065	14	160-5A219 293	5683019014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.13231	-118.22598	PV1 TRANFORMERLESS SYSTEM. USING POWER OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56697	15041-20000-34012	13042 W LULL ST	91605	2	186B161   286	2303021019	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.20872	-118.41755	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:  12KW DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56698	15041-10000-00804	2770 N ROSCOMARE ROAD	90077	5	156B145    80	4378014001	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.12538	-118.46527	Plan check for a PV1 roof-mounted PV system. System size is 9.2 kWac and consists of (2) inverters and (45) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56699	16041-10001-38057	10500 S AVALON BLVD	90003	8	090A207   178	6051028031	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	33.94087	-118.265	PC FOR TITLE 24 ENERGY ONLY. NON HIGH RISETOTAL AFFECTED AREA OF 2392 sq.ftSCOPE INCLUDES NEW LIGHTS RECEPTACLES UNDER EXPRESS PERMIT  16041-70000-38057	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56700	19041-10000-16625	1202 S KENMORE AVE	90006	1	129B197   809	5078032025	R3-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	10/21/2020 12:00:00 AM		Permit Finaled	11/14/2021 12:00:00 AM	ADDRESS	34.04888	-118.2967	Full plan check add new 400 amp service 120/240 single phase. Scope includes lighting, panels and equipment with a total area (in/outdoor) of 13,130-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56701	19041-10000-33394	12775 W MILLENNIUM	90094	11	102B161  1175	4211033020	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	03/23/2021 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	33.97584	-118.4171	Plan check for a commercial gym interior T.I . Scope includes new lighting and equipment with a total lighting area of 7019-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56702	18041-20001-07504	14006 W RIVERSIDE DR #73	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	05-25-2018 Changes to an approved set of plans. Changes include replance lighting fixture with different manufacture. All Changes has been cluded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56703	12041-20000-01846	1100 S BERENDO ST	90006	1	129B197   485	5078026028	R4-1VL	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			01/25/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.05071	-118.29357	upgrade existing 20 units apartments	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56704	17041-20000-19497	20415 W ARBELLA PL	91326	12	219B109   349	2701082025	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.29272	-118.57854	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56705	15041-20000-33596	10250 W SANTA MONICA BLVD Suite 108	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	PIN	34.0586034	-118.41904766	Plan check for Title 24 only. Project site is an existing commercial space (tenant within a mall). Project scope is a tenant improvement. Total lighting area = 848 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56706	12041-20000-17460	15301 W VENTURA BLVD	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM			PC Approved	07/26/2012 12:00:00 AM	ADDRESS	34.15411	-118.46654	energy plan check suite 3000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56707	15041-20000-23708	21650 W OXNARD ST Suite 1450	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lightign area = 1,306 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56708	14041-20000-29557	2134 N THOMAS ST	90031	1	136-5A225  11	5211007013	RD3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Expired	11/24/2016 12:00:00 AM	ADDRESS	34.07015	-118.20501	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(14) SUN POWER E20 327 MODULES(1) POWER ONE PVI-4.2 OUTD TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56709	14041-20000-04717	19631 W STRATHERN ST pv1	91335	3	189B117   301	2105004024	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.21572	-118.56123	pv1, roof mounted solar installation, interconnecting with (E)125a main service PNL. (N) 125A load center. ungrounded system, sized @ 6.25 kW DC, with (25) trina solar #tsm-250pa05.18, (25) OP300 power optimizers, (1) solaredge #SE6000a-us-zb-u	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56710	14041-20000-34846	1950 S SAWTELLE BLVD Suite 303	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.04129	-118.44377	Plan check for energy only. TI to existing office on third floor of office building. New lighting (incl. emergency) and receptacles. 2,890sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56711	14041-10000-22985	778 E 12TH ST # 2	90021	14	123A211    83	5132012025	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.03239	-118.25109	T24, REPLACE HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 702 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56712	12041-10000-08793	2440 S SEPULVEDA BLVD #220	90064	5	123B157  1427	4256008016	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Approved	04/17/2012 12:00:00 AM	ADDRESS	34.03617	-118.43421	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT OF EXISTING OFFICE SPACE  #220 WITH LABORATORY. NON HAZARDOUS AREA AND LESS THAN 400A CONNECTED LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56713	10041-20000-09603	13622-13622 1/2 W FOOTHILL BLVD	91342	7	222B157   155	2513006022	C2-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM			PC Approved	06/29/2010 12:00:00 AM	ADDRESS	34.30717	-118.43031	Interior dining room and restroom remodel Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56714	16041-20000-00733	8318 N DENSMORE AVE	91343	12	192B141   434	2673016058	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.22201	-118.47857	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (26) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56715	17041-20000-43115	1411 N CAPRI DR	90272	11	132B133   299	4425018016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.05498	-118.50275	New 2-story SFD with attached garage and basement.  600A 208Y/120V 3ph-4w service.Building permit under 16010-30000-06368	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56716	19041-20000-16989	10509 W CAMARILLO ST	91602	4	168B177   481	2420004016	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM			Corrections Issued	05/07/2019 12:00:00 AM	ADDRESS	34.15781	-118.35961	PV1.  Install 10.725 kW DC roof mounted grid tied PV system with 27 kWh energy storage system.  (33) modules with 10 kW rated inverter and (2) 13.5 kWh battery units.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56717	19041-10002-07345	21045 W OSBORNE ST	91304	3	195B105    41	2779048009	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.23322	-118.59228	Changes to an approved set of plans. All changes are clouded under delta 4.NOTE: PC only. Permit has been pulled under master application 19041-10000-07345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56718	09041-10018-24270	380 W WORLD WAY NORTH-CONCOURSE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan Review for RFI -8518 IN WHICH LIGHTING DIST BD 3S1BL1 WILL BE SUPPLIED FROM 3SMBP1 AS 3SMBL1 IS NOT LARGE FOR ALL ITS LOADS; FOR RFI-8523  THE 3S3-INV INVERTERS ARE TO BE SUPPLIED FROM A DIFFERENT PHASE BUS IN THE SAME PANELBOARDS.Construct north concourse of TBIT - full plan check , power lighting and energy. Fire alarm under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56719	19041-10000-48030	5121 W JEFFERSON BLVD	90016	10	120B177   680	5049032065	CM-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.02565	-118.35567	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56720	15041-20000-38568	21606 W BLACKHAWK ST	91311	12	204B105   192	2722009013	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Expired	12/18/2017 12:00:00 AM	ADDRESS	34.25821	-118.60013	PV1. NEW SOLAR SYSTEM ON EXISTING ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (27) MODULES-KYOCERA#KU2656ZPA(1)INVERTER-ABB#-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56721	18041-10000-32631	736 S CERES AVE	90021	14	124-5A213  69	5146004025	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	09/07/2022 12:00:00 AM	ADDRESS	34.03707	-118.24395	Power plan check for a new 600-Amp service 120/240v 3-phase 4-wire.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56722	17041-10000-21313	2805 S MCCONNELL DR	90064	5	126B165   650	4308014010	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.04091	-118.40132	$0 permit fee due to senate bill 1222 from 2012PC for rooftop solar. New 15.2KW system. PC for two new SE7600A inverters, 51 Hanwha solar modules, 51 optimizers and one load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56723	19041-10000-42303	2400 W GLENDALE CT	90039	13	147A209   511	5439001041	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	07/09/2020 12:00:00 AM	ADDRESS	34.09799	-118.25945	PC FOR POWER ONLY, SCOPE OF WORK IS ADDING A  HOUSE PANEL,  NEW 600A SERVICE AND PULL SECTION (120/240 1P 3W). SERVICE AND LOAD CALCULATION ALSO PROVIDED.NOTE. All INDIVIDUAL UNITS ARE UNDER SEPARATED PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56724	09041-20001-22451	525-531 W 7TH ST	90731	15	015B197   553	7454003009	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	33.73765	-118.28849	Changes from previously approved plans.  Changes in lighting and load.  Plan check for energy and power.panel c was added with all 29 branch cktsnew.*****TENANT IMPROVEMENT AND STRUCTURAL ALTERATIONS TO CONNECT TWO BLDGS AND CHANGE OF USE FROM RETAIL/ RESTAURANT TO MEDICAL CLINIC WITH PHYSICAL THERAPY ROOM.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56725	17041-10000-45711	11151 W VANOWEN ST	91605	2	183B173   261	2319005036	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.19409	-118.37403	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56726	15041-10000-00912	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"PC FOR ENERGY T24 ONLY. REPLACE EXISTING FLOURESCENT LIGHTSIGN WITH LED LIGHTSIGNS. RETROFIT EXISTING FLUORESCENT LIGHT SIGN WITH THE NEW FACE PANEL. ADDED NEW LED SIGN CONNECT TO EXISTING POWER CIRCUIT.REFERENCE BUILDING PERMIT: 14048-10000-02686. PROPOSED 3'-9"" X 4'-10"" D/F ILLUM. POLE SIGN (9-0)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56727	16041-10000-15253	5101 E MONTEZUMA ST	90042	1	153A225   414	5469008003	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Expired	06/01/2018 12:00:00 AM	ADDRESS	34.11222	-118.20478	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.924KWdc / 3.80KWac.(12)MODULES-SUNPOWER SPR-E20-327(1)INVERTER-SUNNYBOY SMA SB3800TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56728	19041-10001-29132	11574 N SEMINOLE CIR	91326	12	213B117   122	2822023013	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.28266	-118.55649	Expedite per applicant request.(((Plan check for a 11.4KW AC / 13.3KW DC roofmounted system with (1) inverter, (38) modules and optimizers interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56729	18041-10000-17861	1063 N SWARTHMORE AVE #1-102	90272	11	129B125   836	4423016021	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.04833	-118.52494	"FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A RESTAURANT ""PORTA VIA"" WITHIN PACIFIC PALISADES VILLAGE. SCOPE INCLUDES NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 2126 SQ. FT. B#18016-10000-12878"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56730	18041-10000-36594	3415 S SEPULVEDA BLVD 10TH FLR.	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.02055	-118.42347	Energy plan check for an office TI located on the 10th floor of a high rise buidling.  Scope includes new lighting and equipment with a total area of  12802-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56731	17041-20001-23038	22100 W LONDELIUS ST	91304	12	195B101   298	2010010007	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.229	-118.6083	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.55 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56732	13041-20000-29644	550 S HOPE ST SUITE 1825	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	34.04989	-118.25574	PC FOR T24 ENERGY ONLY. TOTAL AREA 4228 SQ FT. EXISTING OFFICES. NEW LIGHTING. WORK DONE IN SUITE 1825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56733	15041-20000-16487	834 W 111TH ST	90044	8	087A199     8	6075008006	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	33.93443	-118.29069	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56734	19041-10000-36896	13207 N BRADLEY AVE	91342	7	225B145   352	2501005009	[Q]MR1-1, [Q]P-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Closed	06/16/2022 12:00:00 AM	ADDRESS	34.31041	-118.46654	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING, CONTROLS, AND CIRCUITS IN 3 EXECUTIVE OFFICE SPACES. TOTAL AFFECTED AREA IS 1678 SQFT. TOTAL NEW CONNECTED LOAD IS UNDER 400AB#: 19016-10000-29353	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56735	18041-10001-27854	5225 N SEPULVEDA BLVD	91411	4	172-5A145  97	2250002147	(Q)C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.16562	-118.46644	*Expedited per applicantInstall New Rooftop solar system on a commercial building, 42.25 KwPDC/ 37.775 kW AC CEC/ 33kW AC central inverter. (130) modules, (65) optimizer P700, (1) inverter, (1) 45 kVA transformer	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56736	17041-10000-42169	2101 E PACIFIC COAST HWY Phase 0	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	04/12/2018 12:00:00 AM		Issued	04/12/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	PC FOR POWER ONLY FOR AN OIL REFINERY(Phase 0). SCOPE INCLUDES ADDING TWO NEW 2.4KV MEDIUM VOLTAGE MOTOR CONTROL CENTERS(MCC) AND RELOCATE FIVE EXISTING MEDIUM VOLTAGE MOTORS TO THE TWO NEW MCCs. PROJECT IS LOCATED IN A HAZARDOUS LOCATION(CLASS 1 DIVISION 2).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56737	17041-10003-43082	16519 S ESTRELLA AVE	90247	15	069B201   368	6121005004	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2018 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	33.88117	-118.28568	Changes to an approved set of plans. Scope of work inlcudes new ground rod and change of address to the plan. *****Revision to approved set: reduced modules qty to 17, and modules model# to SPR-X21-345-D-AC. System now becomes 5.9 kW AC.  This is plan cehck only, permit is covered under master plan.<<PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.03KWdc / 6.72KWac.(21)AC MODULES-SUNPOWER SPR-X21-335-BLK-D-AC>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56738	19041-20002-11122	23150 W AVENUE SAN LUIS pv3	91364	3	171B093   784	2074021035	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1374.02	Electrical	Electrical	Apartment			10/07/2019 12:00:00 AM			PC Approved	10/07/2019 12:00:00 AM	ADDRESS	34.16135	-118.63106	10-07-2019 Changes to an approved set of plan, Changes include update fault current calculation from 1600A main distribuition to performance meter and 400A disconnect. All changes has been clouded. Plan check only.permit fees $0.00 by state senate bill no. 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56739	19041-10000-04413	3139 N CHANDELLE ROAD	90046	4	156B177    37	5570023034	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.12757	-118.3647	PLAN CHECK FOR ENRGY STORAGE SYSTEM IN A SINGLE FAMILY DWELLING WITH EXISTING PV. SCOPE INCLUDES (3) 13.5KWH  BATTERIES (TESLA POWERWALL), NEW LOAD CENTER 200A AND NEW DISTRIBUTION PANEL 200A FOR RELOCATED LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56740	15041-20000-24425	740 S CROCKER ST	90021	14	126A213   437	5146032037	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.03903	-118.24682	THIS PERMIT IS PART OF 3 UNITS. THIS IS FOR PERMIT 736 CROCKER, THIS PERMIT ALSO INCLUDES HOUSE PANEL AND MAIN 600A SERVICE, PLAN CHECKED AND APPROVED UNDER 15041-20000-01570.    OTHER UNITS UNDER SEPARATE PERMITS.	N	N	Express Permit	06/10/2024 12:00:00 AM
56741	15041-10000-04560	11125 W VANOWEN ST	91605	2	183B173   182	2319005017	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.19409	-118.37319	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 15416 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56742	13041-10000-30945	10922 N WHITEGATE AVE	91040	7	208-5A195  35	2552017012	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.2677	-118.30519	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 18 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56743	15041-10000-01644	8430 N TUJUNGA AVE	91352	6	192B173   332	2632006012	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.2231	-118.37917	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 19016 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56744	14041-20000-20242	9249 N FORBES AVE	91343	12	198B133   339	2687008024	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.23896	-118.50006	New roof mounted PV system with Optimizers, total system size 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56745	16041-20000-15241	1625 W OLYMPIC BLVD Suite 920	90015	1	130-5A203 305	5137002033	C2-2D, C4-2D	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.04973	-118.27494	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,477 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56746	11041-10000-09154	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	07/12/2011 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.02224	-118.28008	RESTAURANT, FIRST TIME TENANT, IN A NEW MIXED USE BUILDING.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56747	19041-10001-17397	15287 W SUNSET BLVD	90272	11	129B125   862	4423016077		West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	34.04723	-118.52537	PC FOR CHANGES TO APPORVED SET TO REFLECT MINOR CHANGES IN PANEL. SCOPE INCLUDES ADDITION OF SINGLE CIRCUIT. THIS IS PLAN CHECK ONLY!!!PC for energy only (tailor method employed). scope of work is 2,629SF. Change of use to retail store	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56748	17041-20000-12949	19115 W STAGG ST	91335	3	189B121   595	2104010010	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.21119	-118.54975	PV1.  Install 3.245 kW roof mounted grid tied PV system.  (E) 6 kW system is also on site.  (11) modules with 3.0 kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56749	17041-20001-19175	9550 N DONNA AVE	91324	12	201B121   689	2762033033	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM			PC Approved	06/23/2017 12:00:00 AM	ADDRESS	34.24446	-118.54735	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on SFD.12kW ungrounded system. (43) 290W pv modules.Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56750	11041-20001-13726	4900 N VINELAND AVE 1-58	91601	2	168B173   211	2421011002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			11/01/2012 12:00:00 AM			PC Approved	11/01/2012 12:00:00 AM	ADDRESS	34.1595	-118.37008	Modification to previously approved set of plans to change emergency lighting circuits.          <<<<New 82-unit 100% Sr. Affordable Apartment with on-grade parking.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56751	12041-10000-04862	28090 S WESTERN AVE	90732	15	024B193     4	7442030206	P-1XL, [Q]C2-1XL, [Q]C4-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	ADDRESS	33.76533	-118.31014	PLAN CHECK POWER AND ENERGY FOR T. I. - GROCERY STORE. INSTALL NEW LIGHTING AND NEW EQUIPMENT TO EXISTING SYSTEM. TWO EXISTING SERVICES SUPPLYING BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56752	16041-20000-06199	14646 W KESWICK ST	91405	6	186B149    39	2210029017	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.21016	-118.45257	Plan check for power only. Project site is an existing commercial building (machine shop). Project scope is a new 600-amp service and electrical distribution equipment. Scope of work does not include loads.Note: This tenant is being fed from the electrical service located at 14647 Lull St. Plan check for service is being done under 16041-20000-06194	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56753	16041-10000-41863	19028 W LOGAN LANE	91356	3	174B121   809	2156011021	(Q)RS-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.17392	-118.54875	PV1 6KW AC roof mounted system with (28) panel and (1) central inverter interconnecting through the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56754	19041-20001-06868	8700 S PERSHING DR	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Expedited plan check fee.PV2.  Install 21.96 kW DC / 19.71 kW AC roof mounted grid tied PV system.  (61) modules with (1) 20 kW rated string inverter.System 5 of 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56755	14041-20000-32455	19501 W VINTAGE ST	91324	12	204B117   562	2726014015	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.25191	-118.55838	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 10 KW INTERCONNECTED WITH MAIN SERVICE PANEL. (34) SUNPOWER 327W MODULES(2) POWERONE PVI-5000 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56756	10041-20001-20867	2941 W 70TH ST	90043	8	102B189   584	4008011058	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01, 2352.02	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.97648	-118.3254	Supplemental application to approved plans. New panel and ckts for receptacles. Changes are clouded on plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56757	18041-10000-15246	145 N MAPLETON DR	90077	5	141B153   126	4358003014	RE20-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.0836	-118.43325	PC for power for new two story SFD with subtarenean basement. Installing new 600A service, new panels, lights receptacles and equipment. Permit fees are covered under combo permit 17010-20000-03499.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56758	13041-10000-34790	420 E CULVER BLVD	90293	11	096B149   175	4116010044	[Q]C4-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	33.961	-118.44556	plan check for power and energy. BUILDING RENOVATION, TENANT IMPROVEMENT AND NEW ROOF DECK ADDITION TO (E) OFFICE BUILDING.  NO CHANGE OF USE.  (E) SWITCHBOARD and service to remain.  Chipton-ross.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56759	14041-20001-24842	7010 S HOOVER ST Unit #8	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #8. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56760	14041-10000-31601	3221 W JEFFERSON BLVD	90018	10	120B185   781	5051032030	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	11/13/2014 12:00:00 AM	ADDRESS	34.02574	-118.33124	Remodeling of (E) 3,950 square foot single-story church.  Plan check for energy.  Permit already obtained under 13041-10000-34395	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56761	12041-10001-09644	18782 W FAIRFIELD ROAD	91326	12	207B121   678	2728031032	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2013 12:00:00 AM			Corrections Issued	10/31/2013 12:00:00 AM	ADDRESS	34.26173	-118.54242	SUPPLEMENTAL PLANCHECK FOR 12041-10000-09644. ADDITION OF 5 MODULES AND CHANGE OF MODULES FROM YINGLI 240W TO TRINA 250W . NEW SYSTEM SIZE: 11KW.PREVIOUS PC: Plan check for 9.36KW roof mounted photovoltaic system single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56762	18041-20001-40719	4707 N COLUMBUS AVE	91403	4	168B145   660	2264005026	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM			PC Approved	10/27/2018 12:00:00 AM	ADDRESS	34.15599	-118.46397	expeditepv1install roof mounted v system sized 15.2KW aC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56763	19041-10000-40368	514 E C ST	90744	15	027B209    89	7424001056	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	10/19/2019 12:00:00 AM	ADDRESS	33.77292	-118.25592	Plan check for a fire alarm system located on a 2-story of a commerical building. Scope includes (1) fire alarm panel, and (27) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56764	10041-20000-17297	9649 W LAWLEN WAY	90210	5	144B161   412	4355019043	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2010 12:00:00 AM			PC Approved	09/01/2010 12:00:00 AM	ADDRESS	34.09484	-118.41636	revise panel schedule to as build drawings by inspector	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56765	13041-10000-09244	20364 W VIA URBINO	91326	12	219B113   236	2701060030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.29956	-118.57769	PV 1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.35 KW. STANDARD PLAN. MAIN BUS SIZE 400A. PHOTOVOLTAIC SYSTEM USING 30 MODULES. COMBINER BOX TRANSFORMED INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56766	10041-10000-06419	2208-2212 W BEVERLY BLVD	90057	13	136-5A205 323	5154010020	C2-1	Central	Westlake		YES	2085.00	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.06709	-118.27181	fire alarm system for 1 story + mezzaine building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56767	17041-10000-45331	944 S SERRANO AVE	90006	10	132B193  1104	5080016009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	11/13/2019 12:00:00 AM		Issued	11/13/2019 12:00:00 AM	ADDRESS	34.05422	-118.30619	PC FOR POWER AND ENERGY FOR 32 UNIT 5 STORIES CONDO BUILDING WITH ONE LEVEL OF SUBTERANIAN PARKING. SCOPE INCLUDES NEW 2500 AMP SERVICE WITH TWO MAIN DISTRIBUTION BOARDS AND 32 UNIT PANELS. TOTAL AREA AFFECTED IS 31552 SQ FT. FIRE ALARM VARIANCE HAVE BEEN FILED. B# 17010-10000-04950	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56768	11041-20000-21513	1990 S BUNDY DR Ste 705	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.03419	-118.45559	T.I.  Expanding to new office space.   Plan check is for energy , emergencyFire alarm is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56769	19041-10000-33839	5940 N LINDLEY AVE	91316	5	177B125   799	2159009002	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/05/2019 12:00:00 AM	ADDRESS	34.17839	-118.52711	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER WITH 25 MODULES USING P400 OPTIMIZERS AND ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56770	11041-10000-23363	1028 S WESTWOOD BLVD	90024	5	132B153    38	4363020008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM			Corrections Issued	12/13/2011 12:00:00 AM	ADDRESS	34.06195	-118.44516	T.I. to a retail space with new panels and circuits.  Plan check for POWER and Energy, per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56771	18041-20001-43867	19020 W KINGSBURY ST	91326	12	207B121   552	2728014015	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM			PC Approved	11/25/2018 12:00:00 AM	ADDRESS	34.26291	-118.54717	expeditepv1install roof mounted pv system sized 12.9KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56772	13041-10002-07822	380 W WORLD WAY T38	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM			PC Approved	11/01/2013 12:00:00 AM	PIN	33.94461393	-118.39808495	CHANGES TO APPROVED SET OF PLANS. DELTA 4 CHANGES ONLY. ADDITION AND REMOVAL OF LIGHTS. T24 CHANGES ONLY.FROM ORIGINAL: renovation of retail space. new restaurant. FULL PLAN CHECK FOR POWER AND ENERGY PER INSPECTOR REQUIST. BACK ROOM SUBMITTAL. TOTAL ENERGY 625 SQ FT. ASSIGN TO FRANCIS. LAX AIR PORT CONCESSION. TOM BRADLEY TERMINAL. T38	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56773	18041-20000-15845	20623 W CHESTNUT CIR (#277)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.29312	-118.58348	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56774	19041-10000-13399	210 S ANDERSON ST	90033	14	127-5A219   3	5172010001	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.04565	-118.22676	Plan check for title 24 only . Replace fluorescent troffers with new led retrofit kits. Indoor. 2nd Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56775	14041-10000-13023	2356 S COTNER AVE	90064	5	123B153    99	4322023019	M2-1	West Los Angeles	West Los Angeles - Century City - Rancho Park			2678.00	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	PIN	34.03666589	-118.43667419	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLOURESCENT FIXTURES, TOTAL AREA 11223 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56776	12041-10000-18154	16042 W VOSE ST	91406	6	183B141   332	2224007060	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.19836	-118.48283	New 4.25kw rooftop PV system for an existing sfr.  System is Ungrounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56777	19041-20000-27002	10929 W SANTA MONICA BLVD	90025	5	129B153   545	4324028014	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.04943	-118.43905	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to massage parlor. Total lighting area = 915 sq. ft.Note: Building permit has been issued under 19016-30000-17591	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56778	15041-20000-21562	20200 W SHERMAN WAY 1-20	91306	3	183B113    62	2135038014	C2-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Apartment			07/08/2015 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.20074	-118.57314	Full Plan check for New 20 units appartment 4 story. 800A service with 2 typical unitsfire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56779	19041-20000-14642	1430 E PACIFIC COAST HWY	90744	15	036B213   510	7425022049	[Q]C1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	33.79089	-118.24553	Plan check for Title 24 Energy only for tenant improvement Mini-Mart, load less than 400A. Total area: 1885 sq ft. B19016-20000-11659	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56780	13041-10000-12918	10250 W SANTA MONICA BLVD UNIT 200A	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	Title 24 plan check for a TI for a restaurant space (Unit 200A).  New lighting and power equipment loading < 400 A.  Permit to be issued at electrical plan check counter only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56781	19041-20000-45833	10107 W CAMARILLO ST	91602	4	168B181    77	2420016032	[Q]C2-1XL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.15829	-118.35222	New panel, power, and lighting for (E) commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56782	17041-10001-02436	5200 N LANKERSHIM BLVD	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC FOR CHANGES TO APPROVED SET. REVISED THE CEILING. USING DOWNLIGHTS INSTEAD OF CELING STRIPS. PC FOR DELTA 1 CHANGE ONLY. UPDATED FLOOR PLANS AND T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56783	15041-20000-42785	1470 N KENTER AVE	90049	11	141B137   116	4493017012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.0809	-118.49406	Plan check for PV roof mounted system. System size: 10.0kW with 40 modules and 1 inverter(10.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56784	16041-20000-28003	2102 W COLORADO BLVD	90041	14	162A223   120	5686003018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Issued	08/08/2016 12:00:00 AM	ADDRESS	34.13897	-118.21215	Plan check for power only. Upgrade commercial building's service to 600A. New tenant panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56785	11041-10000-19596	6849 N TOPANGA CANYON BLVD	91303	3	183B101   647	2024005023	[Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.19515	-118.60614	T24 lighting plna check for Sherwin Williams Paint	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56786	15041-20000-43347	16964 W ENCINO HILLS DR	91436	5	159B133    74	2287005059	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.13479	-118.50213	PV1.  Install 11.6 kW AC roof-mounted, utility-interactive PV system.  (2) SMA SB5000TL-US-22 transformerless inverters with (37) SunPower X21-345 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56787	13041-20000-12560	250 E 1ST ST #1100	90012	14	130-5A213 150	5161016014	[Q]C2-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.05038	-118.24114	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON 11TH FLOOR ROOM #1100. 3586 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56788	11041-10000-03350	3900 E CHEVY CHASE DR	90039	4	159B205   748	5593002907	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Public Safety Only			02/22/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	10/21/2011 12:00:00 AM	ADDRESS	34.13327	-118.27281	REPLACE AN EXISTING FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56789	16041-20000-28154	5500 N LANKERSHIM BLVD	91601	2	174B173  1259	2350008025	C2-2D	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.17013	-118.37756	600 AMPS TEMPORARY POWER FOR 8 MODULAR STATE APPROVED TRAILERS. PER APPLICANT: WIRING TO CIRCUITS PREBUILT PART OF TRAILER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56790	10041-10000-13515	5780 N CANOGA AVE # C	91367	3	174B105    79	2149019010	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	34.17493	-118.5972	Ti in an existing restaurtant. Plan check for T24.      Permit is for new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56791	19041-20001-17827	615 W FLORENCE AVE	90044	8	102B201   857	6013024013	C2-1VL	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	08/24/2020 12:00:00 AM	ADDRESS	33.97482	-118.28428	12-18-2019 Changes to an approved set of plan, changes apply to Title 24 Energy only(no power plan check), load less than 400Amps, update service location, new service not located in hazardous location. changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56792	14041-20000-16552	8461 N GLENOAKS BLVD	91352	6	192B177   353	2404019003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.2238	-118.36097	NEW AUTOSHOP REPAIR BUILDING. PLAN CHECK ENERGY AND POWER FOR HAZARDOUS LOCATION.  NEW 600 AMP 120/240V SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56793	18041-20000-23132	22785 W CHARLEMONT PL	91364	3	165B097   433	2078004032	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.14775	-118.62358	Plan check for PV roof mounted system, system size: 11.4kW with 40 modules and 1 inverter(11.4kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56794	13041-10000-32747	1500 W PACIFIC COAST HWY BLDG A	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING ATHIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56795	17041-20000-18643	4534 N VAN NOORD AVE	91604	4	168B161  1071	2362006005	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.15323	-118.41483	installation of new powerwall 5kw (battery back up) to an existing pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56796	15041-10000-25038	5839 S VILLAGE DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/21/2015 12:00:00 AM			Reviewed by Supervisor	09/03/2015 12:00:00 AM	ADDRESS	33.97517	-118.41484	NEW APARTMENT BLDG TYPE A . ONE OF 7 UNITS APARTMENT BUILDING. BLDG NUMBER 6  BLDG APP: 15010 - 10000 - 01751	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56797	19041-30000-45356	12751 W MILLENNIUM 5-165	90094	11	102B161  1235	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	10/07/2020 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	33.9761	-118.41651	FULL PC FOR A TI (FIRST TIME), SCOPE OF WORK IS ADDING TWO NEW PANELS, CONNECTED TO AN EXISITNG SERVICE SWITCHBOARD RATED AT 2000A (208/120 3P, 4W). TOTAL AFFECTED AREA IS 1597 SQFT. ((B#18016-70001-41269)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56798	18041-10000-14588	100 WORLD WAY 140F+B	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLANCHECK FOR T24 ENERGY. SIGN LIGHTING FOR URTH CAFE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56799	13041-10000-16808	330 S CENTRE ST	90731	15	018B201   821	7455019922	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	33.74055	-118.28332	Upgrade existing FACP and replace ntofication appliances to voice in a 3-story police headquarters.  Replacement of 387 devices, building size 125,643 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56800	19041-10000-07826	1660 W RIVERSIDE DR	90031	13	144B213    13	5445001037	C2-1VL-RIO, P-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley			1972.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.09469	-118.24235	PC FOR NEW FA SYSTEM IN 2 STORY BUILDING. TOTAL DEVICE COUNT 75 WITH SINGLE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56801	13041-10002-30038	6841 N MAMMOTH AVE	91405	2	183B153   980	2216024005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.19517	-118.43248	Expedited RSES plan check per applicant request.((((PV1, Install 4.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 19 modules Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56802	15041-10003-11736	6256 N TOPANGA CANYON BLVD C-1200	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	(9/24/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 4.  CHANGES INCLUDE FIXTURE TYPE, ENERGY CALCS, AND PANEL MAIN MAIN OCPD. THIS IS PLAN CHECK ONLY.TI to new commercial building (restaurant). Plan check for power and energy.  Total Sqft. 2235.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56803	12041-10000-04090	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	PIN	33.92817449	-118.43220714	Substation Seperation at 35KV and transfer of load to a new distribution panel at Hyperion. (Plan was originaly submitted on 2008 and expired. New submittal to comply with the requirment.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56804	17041-10000-39246	555 W 5TH ST 31ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	ALTERATIONS IN CORRIDORS AND RESTROOMS ON 31 ST FLOOR OF AN OFFICE BLDGPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56805	16041-20000-25693	15250 W VENTURA BLVD #300	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.15351	-118.46549	Plan check for Title 24 only in existing commercial offie remodel. New light fixture and existing circuits. Total area: 8,870 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56806	18041-10000-48197	434 S SAN PEDRO ST	90013	14	127-5A213 135	5147007020	PF-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.04473	-118.24336	PLAN CHECK FOR ROOF MOUNTED 11.5KVA SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(TS208-5K75) WITH 36 MODULES(RECOM RCM-325-6MA(325W)) CONNECTED TO EXISTING 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56807	16041-10000-05138	658 E VENICE BLVD	90291	11	108B145  1620	4237002006	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	33.98963	-118.46093	TI TO AN EXISTING COMMERCIAL BUILDING (FIRST FLOOR).  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.TOTAL SQUARE FOOTAGE 930BUILDING APPLICATION NUMBER 15016-10000-09294	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56808	11041-20001-21712	4440 N VANTAGE AVE	91604	2	165B165   200	2364002051	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			12/28/2012 12:00:00 AM			PC Approved	01/22/2013 12:00:00 AM	ADDRESS	34.15143	-118.39737	Modification to a previously approved set of plans to combine two separate main swbds.       <<<NEW 30-UNIT APARTMENT WITH GARAGE>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56809	13041-20000-20411	4540 N CHARMION LANE	91316	5	165B133    47	2290026019	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.15237	-118.51091	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 13 KW USING 44 MODULES. USING 2 CENTRAL INVERTERS WITH ISOLATION TRANSFORMER. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56810	14041-20000-02954	17761 W SIDWELL ST	91344	12	219B129   655	2601071007	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.30072	-118.52147	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 TRANSFORMERLESS INVERTER NOSNTANDARD PLAN.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56811	16041-10000-10107	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	(TI) to F.A system, adding 41 devices to (E) F.A Panel (system).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56812	16041-10000-18571	7010 W CHARRICK PL	91042	7	198B201   347	2572045017	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.23854	-118.28375	STANDARD PLAN IS IN USE.PV1, NSTALL NEW 7.19 KW DC ROOF-MOUNTED SOALR ARRAY ON A SINGLE FAMILY HOUSE.(22) MODULES:SUNPOWER SPR-E20-327-C-AC(22)MICROINVERTERS: THE SAME BRAND	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56813	12041-10000-07979	217 N TIGERTAIL ROAD	90049	11	132B141    21	4403011030	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.06206	-118.47941	New addition to an existing single family residence.  600A service upgrade, new main panel, new A/C	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56814	11041-20000-09132	14724 W VENTURA BLVD #1110	91403	5	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	05/10/2011 12:00:00 AM	ADDRESS	34.15162	-118.45395	Plan check T24 Energy for relocate and new lighting in existing office space #1110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56815	17041-20000-07443	11135 W MAGNOLIA BLVD	91601	2	171B173  1385	2350018082	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.16512	-118.37381	ti to an existing commercial building single story.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 8236.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56816	13041-10000-26616	1115 S BOYLE AVE	90023	14	123A221   272	5170008***	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	ADDRESS	34.0308	-118.22044	TITLE 24 PLAN CHECK ONLY. 2 STORY BUIDLING. OFFICES. WORK ON 2ND FLOOR. 6156 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56817	16041-10015-35308	19535 W NORDHOFF ST	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	PIN	34.2363795	-118.55851216	CHANGES TO AN APPROVED SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56818	18041-20000-41500	20611 W DEFOREST ST	91364	3	169-5A111  12	2166019008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.16035	-118.58202	pv1install roof mounted pv system sized 5.2KW AC interconnected with msp.(2) tesla powerwall 5Kw each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56819	18041-20000-21250	19231 W VICTORY BLVD #352	91335	3	180B117   799	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.18678	-118.55214	PLAN CHECK FOR POWER AND ENERGY FOR - INTERIOR NON STRUCTURAL REMODEL AND TENANT IMPROVEMENT (E) 1240 SF DENTAL OFFICE A MEDICAL BUILDING. - TOTAL AFFECTED AREA 1190 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56820	14041-10005-15434	3640 W WILSHIRE BLVD	90010	10	132B193    62	5093019018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			10/24/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.06145	-118.30446	PC for power only. Changing clouded feeders from copper to aluminum and changing AIC value of panel. All changes clouded under delta 6.Note: Permit has been pulled under master application. (PC only).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56821	13041-10000-29461	13111 W COMMUNITY ST	91352	6	192B161    41	2634029006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.22337	-118.41871	PV1, installing roof-mounted photovoltaic system interconnect with main panel. System size: 6.75 KWDC.Transformerless inverter using SOLAREDGE # SE6000A-US, Trina solar modules with power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56822	19041-20002-47556	755 N STRADELLA ROAD	90077	5	141B149   145	4369022003	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM			PC Approved	12/10/2019 12:00:00 AM	ADDRESS	34.08265	-118.45298	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED DELTA 4 CHANGES ONLY. CHANGE MADE TO SINGLE LINE AND PANEL SCHEDULES, ADDITION OF BREAKER TYPES AND SERIES RATED BREAKER CUTSHEETS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56823	19041-20000-29531	10664 W KINNARD AVE #1-4	90024	5	132B153   825	4326025007	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Apartment			07/31/2019 12:00:00 AM	07/20/2020 12:00:00 AM		Issued	07/20/2020 12:00:00 AM	ADDRESS	34.05558	-118.4333	Plan check for power and energy for 4 story building 4 units multi-family, 800A Service 120/240 Volts 3phase 4 W Delta. Total area: 6959 sq ft. B#17010-20000-03770	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56824	12041-10000-02931	8856 N ENCINO AVE	91325	12	195B129   241	2768015012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	34.23191	-118.51556	ROOF-MOUNTED 12.8KW ,40 MODULES PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56825	12041-20000-04660	6614 W HOLLYWOOD BLVD Suite A, B	90028	13	148-5A185 130	5547015013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.10141	-118.33371	New 600A service, switchboard, and subpanels.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56826	14041-20001-24836	7010 S HOOVER ST Unit #4	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #4. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56827	16041-20000-35593	12105 W BLUFF CREEK DR 1ST-2ND FL	90094	11	105B165   936	4211010103	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	33.97901	-118.40436	Plan check for energy only. TI to office, 1st and 2nd floors. New lighting (incl. emergency) and receptacles. 18,469sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56828	11041-10004-14514	7149 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM			PC Info Complete	04/13/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	NEW FIRE WATER DELUGE PUMP BUILDING AT LAX.  FULL PLAN CHECK.((((((( changes made to previously approved set, remove exhust fans from emergency board feedinf fire pumps and remove neutral from the wiring system. 3-2-12))))))))))))))))))(((((( REarrange fire pump cabinet hoock up, and add OC for juckey pump on nermal side, re calculate fult current.)))))))))))))))))))))))))))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56829	14041-10000-05741	338 S WESTERN AVE	90020	10	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			03/03/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.06777	-118.30889	PLAN CHECK FOR T24 ENERGY ONLY. NEWLY CONNECTED LOAD <400 AMPS.  OCCUPANCY WAS CAHNGED FROM MEDICAL OFFICE TO RETAIL. 1355 SQFT, EMERGENCY LIGHTING. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56830	16041-20000-04793	16312 W COMMUNITY ST	91343	12	192B137   224	2689005024	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.2234	-118.48767	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56831	18041-20000-48743	17636 W GLEDHILL ST	91325	12	198B129    74	2766001039	RA-1	North Valley				1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	PIN	34.24176691	-118.51906283	installation of (4) tesla battery 5KWh to an exisitng PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56832	19041-10000-21313	1431 W KNOX ST	90501	15	057B197   111	7351002029	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	33.85442	-118.29964	T-24 PLAN CHECK FOR AN INTERIOR TI OF T-MOBILE RETAIL STORE. SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2027 SQ.FT.TOTAL CONNECTED LOAD IS LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56833	10041-20000-20172	2000 S AVENUE OF THE STARS 10th floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	T.I. for a high rise building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56834	18041-10000-38330	5821 S CENTRAL AVE	90011	9	108B209  1407	5103015035	MR1-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.20	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	33.98962	-118.2566	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56835	12041-10000-02549	2134 S SEPULVEDA BLVD	90025	5	126B153   689	4322019007	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Info Complete	02/03/2012 12:00:00 AM	ADDRESS	34.04078	-118.43812	TI IN AN EXISTING WAREHOUSE. INSTALL LIGHTS IN THE OFFICE AREA. PLAN CHECK FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56836	15041-10001-42455	10545 W AYRES AVE	90064	5	126B157   378	4318002016	R2-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.04347	-118.42029	06/23/16PC FEES ARE $0 due to senate bill 1222.Changes to an approved set of plans. All changes are made under delta 1. Change include resizing the main breaker from 100A to 200A. NOTE: permit is  pulled under PCIS#15041-10000-42455((((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3KW INTERCONECTED WITH MSP.(20) SILFAB SLA 260W MODULES(20) ENPHASE 215 MICROINVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56837	15041-10000-42230	736 E 29TH ST	90011	9	118-5A207 268	5128015041	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.01822	-118.26182	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE EXISTING HID LIGHTING AND REPLACE WITH LEDS FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUAREFOOTAGE 24050	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56838	19041-20000-18146	3315 S COLBERT AVE	90066	11	117B153   368	4249007013	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.0186	-118.43359	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 6.27KW DC/5.985KW AC. SCOPE OF WORK INCLUDES (19) PANASONIC PV MODULES WITH ENPHASE IQ7 MICROINVERTERS, AND A ENPHASE IQ COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56839	15041-10000-35658	1110 S WESTERN AVE #202	90006	10	129B193   694	5080010002	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM			PC Approved	10/26/2015 12:00:00 AM	ADDRESS	34.05041	-118.30886	PC for energy only. T-24, ti to an existing commercial building (optical retail). Adding new lighting and receptacles only. Total sq ft = 850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56840	19041-20000-15081	4429 N EDENHURST AVE	90039	13	159B205   285	5594013010	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.13309	-118.27004	Plan check for battery back up system install into existing PV system, Energy battery system size: 13.5kWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56841	14041-10000-16868	1520 N SAN PABLO ST	90033	14	135A225    64	5202004041	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.0627	-118.20276	Title 24 only.  Total area = 427 sq. ft.Install lighting and X-ray machine (100 A) in existing empty room in a healthcare facility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56842	14041-20000-04030	22737 W BERDON ST	91367	3	174B097   644	2040012005	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.17115	-118.62251	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.4 KW AC USING MICROINVERTER. NEW APPLICATION FOR CHANGE IN SYSTEM DESIGN. USING MICROINVERTER STANDARD PLAN. USING ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56843	15041-10000-35832	5210 N LANKERSHIM BLVD	91601	2	171B173  1384	2350018081	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.16634	-118.37406	NEW FIRE ALARM SYSTEM 125 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56844	13041-10000-04653	2500 S NAVY WAY	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	33.73363	-118.2408	Installation of two above ground fuel tanks with four pumps.  Class 1 Div 2 hazardous location and methane zone.  The power panel supplying the four pumps, which is listed on the plans as 'existing,' has been permitted but has not received final approval from LADBS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56845	12041-10001-02284	127 S SAN VICENTE BLVD Bulletin-149CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Revision bulletin # 149.  Plan check only. Relocate 800A feeders from US-A to US-B switchboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56846	18041-10000-46479	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	Yes	1952.02	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	PC FOR TI TO A COMMERCIAL SOUND STAGE. SCOPE OF WORK INCLUDES NEW 800A SWITCHBOARD, 18 NEW EQUIPMENTS, 30 KVA TRANSFORMER AND 100A PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56847	14041-20000-17252	10201 N MOUNTAIR AVE	91042	7	204B197   958	2558023032	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			06/26/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.2542	-118.29329	Plan check for power and energy. New 10-unit, 3-story apartment building (plus subterannean parking garage). Fire alarm filed under variance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56848	13041-10000-24253	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	PLAN CHECK FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT. TENANT IMPROVEMENT FOR A NEW RESTAURANT. 3,197 S.F. 3 NEW PANELS.FA ALARM PLAN BY A DIFFERENT CONTRCATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56849	15041-20001-02895	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	Changes to approved set.  PC at request of inspector.  Emergency lights and exit signs are to be connected to normal circuit instead of inverter (with 90 min battery backup unit equipment).    **********    TENANT IMPROVEMENT FOR BUILD OUT OF NEW OFFICE & SHOWROOM WITHING (E) CORE & SHELL BUILDING.  FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.  PC IN ACCORDANE TO 2008 ENERGY DUE TO DATE OF BUILDING SUBMITTALSQUAREFOOTAGE FOR WAREHOUSE UNCONDITION SPACE NOT INCLUDED IN FEES TO BE ADJUSTED AT LATER TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56850	12041-10001-15293	600 W 7TH ST	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM			PC Approved	07/30/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	Plan check only. Plan check for revision to feeders supplying 75KVA transformer from #2 AWG to #1 AWG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56851	16041-10000-26295	9618 N VARIEL AVE	91311	12	201B105   207	2746006019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.24536	-118.59269	Plan check for T-24 only.  Remove HID fixtures and replace with new LED fixtures. Total affected area: 16,995 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56852	14041-10000-04467	10344 N LANGMUIR AVE	91040	7	204B193   460	2559004032	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.25697	-118.30904	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. 5KW DC.(20) ENPHASE M215 MICROINVERTER(20) RENESOLA JC250M MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56853	11041-10000-14917	12412 W PACIFIC AVE	90066	11	111B153   384	4235014002	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.00	Electrical	Electrical	Apartment			07/18/2011 12:00:00 AM	07/18/2011 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.00241	-118.43318	NEW FIRE ALARM SYSTEM FOR A NEW APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56854	15041-10001-03694	200 WORLD WAY SPACE 225	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Revisions to approved set.  Additional circuits and other miscellaneous changes under delta-3 revisions only.  (((Plan Check for power and energy for new restaurant. Total area = 1604 sq. ft. 2 New panels, exisiting service)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56855	19041-30001-08859	10940 W WILSHIRE BLVD 18TH FL	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.05822	-118.4452	03/14/2019 Plan check for Title 24 only. Project site is a tenant space in a commercial high-rise. Project scope is a tenant improvement. Total lighting area = 810 sq. ft.Note: Building permit has been issued under 19016-40000-03937*****Original Work Description*****EXISTING BRANCH CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56856	12041-10001-11205	635 W DOWNEY WAY	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.01874	-118.28387	(( FIRE PUMP EMERGENCY BOARD MODIFIED, NEW SET IS SUBMITTED. MODIFICATIONS ARE ALL DONE PER MZ)))  12041-10000-11205 WORK DESCRIPTION - Re-route of conductors in duct bank.  4000A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56857	19041-10000-24633	8404 W MELROSE AVE	90069	5	141B173   526	5528016034	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.08326	-118.37342	P.C FOR TITLE-24 T.I FOR A RETAIL STORE. TOTAL AFFEECTED AERA 655 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56858	11041-10000-11311	10550 W WILSHIRE BLVD 1-50	90024	5	135B153   584	4326003***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2656.00	Electrical	Electrical	Apartment			06/02/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	11/23/2011 12:00:00 AM	ADDRESS	34.06277	-118.43255	Modification to an exisiting fire alarm for a 14 story condominium building.  The modification is the replacement of the existing fire alarm panel and the addition of a announciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56859	12041-10000-22827	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	PIN	34.12750533	-118.21285206	T.I. to the entire building.  New high voltage (4800V) service, new panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56860	12041-20000-29302	18700 W VENTURA BLVD #140	91356	11, 3	174B121   811	2161026002	(Q)C2-1VL, C2-1VL, R1-1	South Valley, West Los Angeles	Encino - Tarzana, Palms - Mar Vista - Del Rey	Mar Vista, Tarzana		1394.01, 2719.02	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.17045	-118.54081	Plan check for power and energy. 3902 sqft. Restaurant with over 100 occupants per applicant. LYFE KITCHEN.RESTAURANT T.I. IN (E) RESTAURANT - INDOOR AND OUTDOOR SEATING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56861	16041-20000-34239	2631 W SOUTHWEST DR B	90043	8	105B189  1430	4007020017	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	33.9813	-118.3224	ti to an existing commercial space.  plan check for energy only.  total square footage 600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56862	14041-10000-33832	1360 E 16TH ST	90021	14	121-5A213 364	5130015006	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.02532	-118.24716	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56863	16041-10002-14568	1616 W 209TH ST # 3	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM			PC Approved	07/13/2016 12:00:00 AM	ADDRESS	33.84074	-118.3073	07/13/16Changes to an approved set of plans. Changes include adding a 20A fuse to the 30A AC disconnect, upgrading the subpanel 125A to 200A subpanel, and upgrading the main service panel from 100A to an 400A 4 bank meter. The address for the tenant is actually Unit 3, not Unit 1. Note: permit is pulled under PCIS#16041-10000-14568 and PCIS#16041-10001-14568((((CHANGES TO APPROVED SET OF PLANS. CHANGE INCLUDES USE OF 8 MODULES AND CHANGE INVERTER TO SOLAREDGE SYSTEM WITH POWER OPTIMIZERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56864	18041-20001-08960	14837 W WYANDOTTE ST	91405	6	186B149   708	2218020023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			PC Approved	03/17/2018 12:00:00 AM	ADDRESS	34.20313	-118.4566	expeditepv1install roof mounted pv system sized 14.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56865	16041-20000-20732	8633 N WOODLEY AVE	91343	12	195B137   956	2689024022	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.22755	-118.48551	Plan check for Title 24 only for T.I. existing restaurant (Wing Stop). Total area: 1,941 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56866	19041-10000-35093	1515 W 190TH ST Ste. 555	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	TENANT IMPROVEMENT WORK ON APPROX. 3,814 SF OF TOTAL FLOOR AREA IN SUITE# 555. INSTALLING LIGHTS. T-24 ENERGY ONLY. PERMIT FOR NEW CIRCUITS.BULDING PERMIT: 19016-40000-23716	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56867	12041-10000-12810	1905 S ARMACOST AVE	90025	11	123B149   235	4259020005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/04/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.03603	-118.45531	Plan check new fire alarm system for charter school.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56868	19041-20000-04244	9728 W ARBY DR	90210	5	156B157   427	4385014023	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.12099	-118.4262	Plan check for PV roof mounted system and Battery energy storage system, System size: 20.475KW with 63 PV Modules and 2 inverters(7.6KW and 11.4KW) and 3 battery Tesla powerwall 2.0 9.8kWh connected to 600A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56869	18041-20001-34093	16908 W SAN FERNANDO MISSION BLVD	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Issued	11/16/2018 12:00:00 AM	ADDRESS	34.27132	-118.50018	11/16/2018 Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to restaurant. Total lighting area = 3,080 sq. ft.Note: Building permit has been issued under 18016-20000-08692*****Previous Work Description*****INSTALL 20 PLUGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56870	13041-10000-08823	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	04/12/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	T24 plan check for an office room remodel.  New lighting being installed.  No emergency lighting in the space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56871	14041-10000-21086	13031 W JEFFERSON BLVD 300	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	33.97451	-118.42531	PC FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT OF (E) OFFICE BUILDING : NEW NON-BEARING PARTITION WALLS , NEW CEILING PANELS , NEW MILLWORK , FINISHES . TOTAL AREA  21190 SQ FT.METHANE HAZARD SITE.FIRE ALARM VARIANCE FILED ON 9/18/2014.B# 14046-10000-14892	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56872	17041-20000-41503	1812 S ROXBURY DR	90035	5	129B165   711	4307013027	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.04821	-118.40115	permit fee $0.00 by state senate bill no. 1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19.80 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56873	16041-10000-38557	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Expired	11/23/2022 12:00:00 AM	ADDRESS	34.10229	-118.33907	PC FOR NEW LIGHTING IN SHOE STORE. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56874	19041-20000-39215	8836 S READING AVE 1-8	90045	11	096B169   951	4125017010	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Apartment			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	33.95676	-118.38145	Plan check for new Fire alarm system for new 8 units apartment. Total fire alarm device: 33 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56875	14041-20001-21421	12280 N DERWENT AVE	91326	12	219B121    76	2820001026	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.29659	-118.54981	Expedited plan check per applicant request.  (((PV1.  Install 5.886 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56876	15041-20000-44045	9627 N DORRINGTON AVE	91331	6	201B149   606	2644019010	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.24539	-118.44603	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (17) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56877	12041-20001-23641	3658 W 3RD ST	90020	10	135B197   188	5502005053	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.06889	-118.2959	Modification to previously approved set of plans.  The modification is to relocate the service.  The site is located in a methane zone.  Existing permit. 12041-20000-23641.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56878	14041-10005-17121	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.03941	-118.25893	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 39 BULLETIN 42. CHANGES INCLUDE RELOCATING PANELBOARDS ON THE SINGLE LINE DIAGRAM, RELOCATING LOADS ON PANEL SCHEDULES, RELOCATING CIRCUITRY ON THE FLOOR PLANS, REVISING SERVICE LOAD CALCULATIONS, AND REVISING TITLE 24 CALCULATIONS.NOTE: PC ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56879	18041-20000-48747	3130 N BEACHWOOD DR	90068	4	157-5A191 151	5581027032	RE9-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.12681	-118.31757	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWdc/10 kWac and consists of (1) inverter, (32) modules, (2) battery back-up units, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56880	13041-20000-33925	22601 W SANTA SUSANA PASS ROAD	91311	12	210B101    11	2723002018	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.27227	-118.6163	T24 FOR EXISTING CHURCH. SCOPE OF WORK IN BATHROOMS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56881	19041-10000-33535	6112 S ST ANDREWS PL	90047	8	105B193   722	6001017009	M2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Issued	10/07/2019 12:00:00 AM	ADDRESS	33.98383	-118.31132	POWER PLAN CHECK FOR 800A SERVICE WITH 200A PANEL CONNECTED AND 3 FUTURE LOADS. SERVICE UPGRADE FROM THREE 200A SERVICES TO ONE 800A SERVICE PER DWP REQUEST.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56882	10041-20000-12623	15910 W VENTURA BLVD 9TH FL	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	08/26/2010 12:00:00 AM	ADDRESS	34.15561	-118.47969	ENERGY PLAN CHECK 9TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56883	16041-20000-41855	7277 N GLENHAVEN CT	91307	12	186B089   579	2027049025	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.20386	-118.64865	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP. Derating the main to 175A. 10.56kW system. (33) 320W ac modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56884	11041-10001-02008	20801 W RINALDI ST	91311	12	210B109   548	2706007024	(T)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.00	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	10/19/2011 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.27025	-118.58647	REVISED  PLANS- ADDING  4 FA DEVICES((((((((New fire alarm system for the athletics building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56885	18041-20002-47866	15455 W SHERMAN WAY pv3	91406	6	183B145   785	2222025***	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.20148	-118.47029	8/15/19changes to an approved set of plans delta 1 only. changes to relocation of solar modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56886	12041-20000-20102	7040 N VALJEAN AVE	91406	6	183B141   248	2224010034	(Q)M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.19864	-118.48571	Showrrom T.I Title 24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56887	17041-10000-12247	707 W WILSHIRE BLVD 10th Floor	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.04893	-118.2572	Plan check for Title 24 only in existing space T.I. in rest room and  elevator lobby. Total area: 1,325 sq ft.     Permit pulled online under #17041-90000-12314	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56888	14041-10000-10832	14651 W OXNARD ST	91411	6	177A149    92	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.17954	-118.4527	NEW FIREALARM MONITORING SYSTEM. 1 PANEL 1 ANNUNCIATOR AND 13 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56889	16041-20000-22722	5700 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.06218	-118.35303	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MAIN LOBBY AREA. 2522 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56890	19041-20000-26365	12400 W WILSHIRE BLVD STE 1440	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM			PC Info Complete	07/10/2019 12:00:00 AM	ADDRESS	34.04157	-118.47031	T24 PLAN CHECK FOR TI TO EXISTING HIGH RISE COMMERCIAL BLDG SUITE 1440. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1,419 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56891	17041-20000-36367	10400 N FARRALONE AVE	91311	12	204B101    66	2723017116	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.25915	-118.61019	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56892	14041-10000-08724	1916 E 1ST ST	90033	14	129A221   284	5174016027	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			Verifications in Progress	06/03/2014 12:00:00 AM	ADDRESS	34.04613	-118.21695	PV2 ROOF MOUNTED 3PHASE SYSTEM. TOTAL SYSTEM SIZE 10KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56893	19041-30000-03379	1121 S GLENDON AVE	90024	5	132B153   200	4363022003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.06034	-118.44439	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to a restaurant. Total lighting area = 5,371 sq. ft.Note: Building permit has been issued under 18014-10000-06350	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56894	10041-10002-02737	12920 W RUNWAY ROAD	90094	11	102B157   315	4211021030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			03/31/2011 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	33.97447	-118.42112	PROPOSED 4-STORIES, 52-UNITS CONDOMINIUM W ONE LEVEL BASEMENT PARKINGDELTA 3 REVISIONS TO PERMITTED SET OF PLANS - Installed 2 new 45KVA Stepup transformers 208:480 for elevators and changed to AL feeders and type of conductors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56895	16041-10001-14759	13583 W RAYEN ST	91331	6	198B157   520	2625026014	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	34.23872	-118.42919	rechecking plans for lost set	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56896	16041-10000-43107	2625 S VERMONT AVE	90007	8	123B197  1022	5054028029	[Q]C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	01/06/2017 12:00:00 AM	ADDRESS	34.03195	-118.29175	Plan check for Title 24 only remove outdoor lighting and replace with new LED fixtures, existing wiring to remain. Total outdoor area: 105,800 sq ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56897	13041-10000-26386	15931 W KALISHER ST	91344	12	213B141   298	2666007016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.27749	-118.47928	PV1. ROOFMOUNTED SOLAR ARRAY. INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 4.41 kW. 18 TRINA TSM 245 MODULES. 1 POWERONE AURORA PVI 4.2. 2 STORY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56898	16041-20001-18014	9117 S LA SALLE AVE	90047	8	094-5A195 106	6037006025	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM			PC Approved	05/28/2016 12:00:00 AM	ADDRESS	33.95402	-118.30587	RSES expedited plan check per applicant request.  PV1.  Install 3.36 KW roof mounted PV system.  (12) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56899	18041-10000-23313	14093 N BALBOA BLVD	91342	7	228B137   187	2603007031	[T][Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.31962	-118.48691	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56900	18041-20002-04018	926 N NORDICA DR	90065	1	153A221   316	5475017025	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.11284	-118.22039	06/14/2018 Changes to an approved set of plans. The Tesla PowerWalls and associated distribution equipment has been removed. The scope of work has been reduced to the PV system only. 3/12/2018changes to an approved set of plans.  changes to include addition of (2) AC disconnects.  changes are noted delta B only.  (((PV1.  Install 3.9 kW PV system.  (12) modules with 3.8 kW rated string inverter.  27 kWh energy storage system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56901	11041-10000-23063	8540 S SEPULVEDA BLVD	90045	11	096B165   472	4107035017	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM			Corrections Issued	11/20/2011 12:00:00 AM	ADDRESS	33.96016	-118.39599	New (N) FUEL CELL energy  system ON (E) GARAGE BUILDING ON 6TH FLOOR AND ROOFTOP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56902	16041-10001-34165	10250 W SANTA MONICA BLVD # 1855	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	{Plan check only} Revision to approved set due to floor plan changed and updated load calculation. Changes are noted under Delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56903	15041-20000-32707	222 N CARMELINA AVE	90049	11	132B141    47	4405004007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.06095	-118.48416	Plan check for a Pv1 roof-mounted PV system. System size is 12.5 kWac and consists of (50) micro-inverters, (50) modules, and (1) load center.NOTE: FEES $0 DUE TO SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56904	17041-10000-18554	232 E 2ND ST Suite G-1-240	90012	14	129A213    28	5161024034	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM			PC Info Complete	07/21/2017 12:00:00 AM	ADDRESS	34.0495	-118.24258	Plan check for power and Title 24.  First time T.I. of bank space including new ATMs.  Total area = 1,859 sq. ft.       Building permit #17016-10000-14730	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56905	18041-20000-04864	9671 N SUNLAND BLVD	91040	7	201B177   261	2542018030	(Q)C1-1VL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.24723	-118.358	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56906	18041-10000-01314	17331 W TRAMONTO DR Bldg # 6	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Issued	04/09/2018 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 6 (CAMPUS STYLE)SCOPE INCLUDES 51 DEVICES AND 1 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE. B# 15010-10001-03646 BUILDING 6 PLAN B1   4 UNITS 4 STORY TYPE IIA  APARTMENT BUILDING WITH  ATTACHED GARAGE .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56907	14041-20000-13008	5166 N TOWNSEND AVE	90041	14	163-5A227 268	5669013025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.14151	-118.20097	PV1 MICROINVERTER STANDARD PLANInstallation of roof-mounted solar array on SFD. System size: 5.1kW(20) EnPhase M-215-60 microinverters(20) Solar World SW-255W MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56908	11041-10000-02953	1825 E 22ND ST	90058	14	118-5A215 107	5167006014	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Closed	07/02/2012 12:00:00 AM	ADDRESS	34.01646	-118.23907	CHANGE OF USEFROM SEWING FACTORY TO COLD STORAGE WAREHOUSE- NEW SERVICE AND PANELBOARDS AND COOLER FANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56909	15041-10000-39995	23330 W OXNARD ST	91367	3	177B093   845	2041006017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.1777	-118.63561	PV1. Install roof mounted PV system sized 13.65 kW. Interconnectd with main service panel.(42) SunEdison 325W Modules(42) SolarEdge Power Optimizers(1) Solar Edge SE11400A-US Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56910	19041-20001-40949	3221 W GLENHURST AVE	90039	13	153B209  1168	5437011004	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.11194	-118.25748	PV1. INSTALL 4.2 KW DC ROOFMOUNTED PV SYSTEM WITH (12) MODULES AND MICROINVERTERS.INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-40949	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56911	14041-20000-33020	642 E 118TH ST	90059	15	084B205   720	6084004009	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	33.92632	-118.26379	pv1install roof mounted pv system sized 3.4kw interconnected with msp.(16) hyundai heavy his m250 modules(16) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56912	16041-10000-42851	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	Full Planc check of a new commercial building core and shell (expected to be a distribuition center). New serice rated at 800 amps 277/480 3phase 4wire. Indoor lighting for restroom only. Total sqft =  72468.No DWP service sheet provided(Per supervisor(Francis) it was ok to approve main distribution at 65KAIC). Field ispector to verify fault current provided from DWP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56913	16041-10000-01443	1515 N VERMONT AVE 6TH FLR	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.09867	-118.29207	T-24, TI TO EXISTING MEDICAL OFFICE SPACE ON 6TH FLOOR WITH NEW EYE TESTING STATIONS AND REMODEL EXISTING RECEPTION. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ FT:1054	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56914	18041-20000-14865	21250 W CALIFA ST #106B	91367		174B105    16	2149002018							Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.1769	-118.59414	Tenant improvement for (E) commercial space.  Plan check for energy.  Building permit under 16016-20000-24392.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56915	11041-20000-16189	1266 W JEFFERSON BLVD 1-8	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/02/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29348	New 3.23 KW PV System for Apartment building #1266	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56916	14041-10000-18116	6301 S VISTA DEL MAR	90293	11	096B149    31	4116005001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Expired	08/10/2016 12:00:00 AM	ADDRESS	33.96263	-118.45058	Install roof mounted solar system on existing residential building.  Total system size = 4.2 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56917	18041-10000-47023	13101 W SAYRE ST	91342	7	228B157    54	2511016900	OS-1XL	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.324	-118.41849	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS  236,942SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56918	14041-20001-09566	16357 W PLUMMER ST	91343	12	198B137    32	2677020013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.24309	-118.48919	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56919	18041-20000-24275	5876 W 77TH PL	90045	11	099B169   138	4105009019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	33.97066	-118.3866	Plan check for battery back up system to existing PV system. battery Tesla Powerwall	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56920	16041-20001-19690	13107 W AZTEC ST	91342	7	228B161   592	2511018008	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.32004	-118.41862	EXPEDITE PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.5KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56921	12041-20000-08166	10861 W WEYBURN AVE 1st Floor	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	ADDRESS	34.06247	-118.44344	T.I. to the first floor of garage level.  Instaall general/emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56922	19041-20000-15554	6100 N WOODLEY AVE	91436	6	177B141     3	2251002906	OS-1XL-RIO, [Q]PF-1XL-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	12/09/2020 12:00:00 AM	ADDRESS	34.18088	-118.48309	Interim ozone system for DC Tillman Water Reclamation Plant.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56923	19041-10000-07165	123 S ROBERTSON BLVD	90048	5	138B169   433	4334001900	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.07462	-118.3839	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR AND OUTDOOR) - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56924	15041-10001-26552	3003 W RODEO ROAD	90018	10	117B185    65	5044011010	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.02028	-118.32915	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL NEW 6.36 KW DC ROOF-MOUNTED SOLAR ARRAY ON  SINGLE FAMILY HOME.(24) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56925	10041-20000-15055	633 W 5TH ST 53rd Floor	90071	9	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	09/22/2010 12:00:00 AM		Permit Finaled	12/10/2010 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check T-24 Energy (general/lighting) office TI on the 53rd Fl at US Bank Tower. Existing lighting ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56926	19041-10000-35842	7548 S MIDFIELD AVE	90045	11	099B173   206	4127002015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	33.96885	-118.37422	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 28 MODULES USING P400 OPTIMIZERS AND 2 ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56927	17041-10000-32048	12663 W FILMORE ST	91331	7	213B161   439	2527029015	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.28091	-118.40933	Installation of roof-mounted solar PV system on a SFD, 7.6kW AC/ 10.2kW DC system. (40) modules, (40) power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56928	19041-20000-33031	6600 N VAN NUYS BLVD	91405	6	180B149   420	2237001017	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/17/2020 12:00:00 AM		Issued	08/17/2020 12:00:00 AM	ADDRESS	34.19081	-118.44843	2500A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56929	18041-20000-19258	19524 W NORDHOFF ST	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.23527	-118.55871	Plan check for Title 24 only. Project site is a tenant space in an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 4,339 sq. ft.Note: Building application has been generated under 18016-30000-09586	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56930	19041-20000-21175	1900 S FIGUEROA ST	90007	9	124-5A205 238	5126008018	C2-2D-O-CPIO	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			Corrections Issued	06/04/2019 12:00:00 AM	ADDRESS	34.03412	-118.27196	T24 PLAN CHECK FOR LIGHTS AND OUTLETS ONLY IN EXISTING CAR DEALERSHIP. TOTAL SQUARE FOOTAGE  = 11378SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56931	19041-20000-52578	4204 S GLENCOE AVE	90292	11	108B153  1222	4230006010	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	08/26/2022 12:00:00 AM		Issued	08/26/2022 12:00:00 AM	ADDRESS	33.98849	-118.44124	FULL PLAN CHECK, NEW 5000A SERVICE, T24 INCLUDED, TOTAL SQUARE FOOTAGE = 252,360 SFSCOPE OF WORK INCLUDES(Building 3)BLDG PERMIT: 19010-10000-058431 OF 3 Electrical Application ELECTRICAL FOR BUILDING 2: 19041-20000-52607ELECTRICAL FOR BUILDING 1: 19041-20000-52609One Electrical permit shall be issued due to there is 1 building permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56932	15041-20000-01678	21820 W BURBANK BLVD Suite #201	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.17228	-118.6032	Plan check for energy only. TI to office, new lighting (incl. emergency) and receptacles. 4,123sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56933	17041-30000-39388	18840 W SHERMAN WAY	91335	3	183B121   135	2126001001	(T)(Q)RAS4-1-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	Apartment			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.20083	-118.54423	Plan check for new fire alarm system for 49 units appartment. Total fire alarm devices: 147 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56934	15041-10000-12943	510 S BURNSIDE AVE	90036	4	135B181   237	5509005014	R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.06599	-118.35011	REPLACEMENT OF 1 FIRE ALARM PANELS AND 300 FIRE ALARM DEIVCES. PC FOR FIRE ALARM SYSTEM. DEVICES CHANGE 1 FOR 1, EXCEPT ADDING LOW FREQUENCY HORN IN THE APARTMENT SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56935	15041-20000-14565	12751 W MILLENNIUM Building B	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Title 24. Plan check for energy for energy only. Existing retail building. Adding new lighting including emergency. Total sqft. 2,700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56936	14041-20000-10047	12490 W FIELDING CIR	90094	11	102B161  1250	4211034031	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	33.9788	-118.41237	New senior living facility: 5 levels of senior living with 175 independent living units, 24 assisted living units and amenity spaces over parking at building foundation level. high rise residential. pc for power and energy. new construction. per building submittal, pc inaccordance to 2008 NEC((NOTE: NEW CONSTRUCTION IN HAZARDOUS LOCATION. PROJECT IN METHANE ZONE)))CUSTOMER HAS PRE-MADE CHECK. ABOUT 90% FEES COVERED. ENSURE DURING PLAN CHECK ADDITIONAL TIME IS ADDED FOR METHANE COMPLIANCE STANDARDS AND FOR UNIT SMOKE DETECTORS. FIRE ALARM VARIANCE WILL NEED TO BE FILED AS A CORRECTION.10/3/14 - fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56937	14041-20000-17699	2810 N HYPERION AVE	90039	4	151-5A205 199	5434036008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	PIN	34.10824019	-118.27122784	Remodeling of (E) night club bar.  Plan check for Title 24 Part 6 for changes to lighting system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56938	17041-20000-42262	8755 W YATES ST	91040	7	204B189   414	2546002019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.25675	-118.32433	pv1install roof mounted pv system sized 5kw interconnected with msp, with battery back up.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56939	16041-20001-09890	220 N BRISTOL AVE	90049	11	132B137   230	4405019019	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	34.05934	-118.48845	2/9/2018recheck plans in compliance with 2014 NEC.See comments.....permit under building combo 15010-10000-03062, this is plan check only. (((Plan check for power only. NEW 2-STORY SINGLE FAMILY DWELLING W/BASEMENT. 1600A service. 22,715sqft.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56940	17041-10000-28866	604 S MAPLE AVE	90014	14	127-5A211 145	5148023027	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Approved	08/21/2017 12:00:00 AM	ADDRESS	34.04361	-118.24786	OFFICE TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56941	10041-10000-22098	310 W WASHINGTON BLVD BLDG #3	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 7 UNIT TOWN HOME.   (BUILDING #3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56942	16041-10000-00230	12025 W VOSE ST #4	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.3952	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56943	17041-20000-03783	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Closed	05/01/2019 12:00:00 AM	ADDRESS	34.30155	-118.46112	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 3366.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56944	11041-10000-27133	9229 N SEPULVEDA BLVD	91343	7	198B145   269	2656026004	R4-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Apartment			12/20/2011 12:00:00 AM			Verifications in Progress	03/21/2012 12:00:00 AM	ADDRESS	34.23807	-118.46786	Plan check for roof mounted photovoltaic system for apartment building. 96KW supplying house panel and 3KW supplying for each units (81).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56945	14041-10000-09595	633 W 5TH ST # 6400	90731	15	015B197   195	7451029032	[Q]R3-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	33.73956	-118.29085	TENANT IMPROVEMENT IN SUITE 6400PLAN CHK IS FOR TITLE AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56946	18041-20002-12992	16929 W DEVONSHIRE ST	91344	12	204B133   147	2684012044	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.25767	-118.50122	08/01/2018 Changes to an approved set of plans. Changes have been clouded. Changes have been made to reflect field condictions. Title 24 complaince forms have been updated to reflect new lighting layout.04/16/2018 Changes to an approved set of plans. Changes have been made to reflect field conditions. Single-line diagram and load home-runs have been updated. *****Previous Work Description*****PC for T24 only for new lighting for change of use from retail to restuarant. Installing new lights, receptacles and equipment. B#17016-20000-28924.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56947	17041-20001-32975	18913 W SHERMAN WAY	91335	3	183B121    83	2104034014	[Q]C1-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.20129	-118.54532	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 14.7 kWac and consists of (64) modules, (64) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56948	10041-10000-05112	610 S RAMPART BLVD	90057	1	133-5A201  20	5141009023	C2-2	Central	Westlake	MacArthur Park	YES	2087.20	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.062	-118.28146	REMODEL COMMERCIAL SPACE TO A SUBWAY SANDWICH SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56949	16041-10000-20255	1901 N ROWAN AVE	90032	14	135A229    60	5215018011	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.06511	-118.18825	Minimum Permit fee due per California Senate Bill 1222.Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10.8 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56950	18041-20000-00208	515 S FLOWER ST #4860	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 only. Project site is a portion of the 48th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 5,503 sq. ft.Note: Building aaplication has been generated under 17016-10000-34733	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56951	13041-10000-26174	359 S LA BREA AVE	90036	4	135B181   359	5508001031	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	12/24/2013 12:00:00 AM		Permit Closed	05/06/2014 12:00:00 AM	ADDRESS	34.06719	-118.34433	New 800A service and distribution board for core and shell - single story restaurant building.  Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56952	11041-10000-10631	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/24/2011 12:00:00 AM	05/24/2011 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	PIN	34.05182951	-118.41257696	BRAND NEW FIRE ALARM SYSTEM IN AN EXISTING  2-STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56953	15041-10000-15646	111 E UNIVERSAL HOLLYWOOD DR 35th FLOOR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.13855	-118.36112	Energy plan check for 35TH floor office T.I. Scope includes a completed demolation for the whole floor except exising panels and transformers; all circuits, lighing and receptacles will be new. Total sq. ft. 20,185 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56954	13041-10000-33089	2800 N PHELPS AVE	90032	14	139-5A233  11	5217005012	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.07845	-118.17706	PV1.  Install 6 kW roof-mounted PV system, interconnect with main service panel.  24 modules: Trina Solar TSM-250PA05.18.  Transformerless inverter: SE6000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56955	15041-20000-18517	19155 W VICTORY BLVD #3	91335	3	180B121   526	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.18675	-118.55116	Plan check for PV roof mounted system. System size: 8kWAC with 35 modules and 2 inverters 4.0kW connected to 200A unit panel and connected to 600A Meter Bank	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56956	12041-20000-29736	8900 N DE SOTO AVE Bldg 104	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.23162	-118.58832	New laboratory, with medium voltage substation, loads and lighting.  (Campus System).  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56957	15041-20000-26942	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLANCHECK FOR T24 ENERGY. PARKING GARAGE ENTRANCE RAMP AND EXIT TUNNEL. 18,648 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56958	19041-10000-47411	11764 W CANTON PL	91604	2	159B169   304	2377020006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			Reviewed by Supervisor	11/22/2019 12:00:00 AM	ADDRESS	34.13338	-118.39037	[EPLAN]C NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 11.34KW DC/10KW AC, WITH 36 MODULES (HANWHA Q-CELLS), 36 POWER OPTIMIZERS (P400),  AND A CENTRAL INVERTER WITH (SE10000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56959	16041-20000-31341	515 S FIGUEROA ST Parking-Level D	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for power and energy. Project site is an existing commercial high-rise building. New 3-hour fire-rated room classified as Class 1, Division 2 used for the diesel fuel tank. Total lighting area = 612 sq. ft. New exhaust fan and leak detection panel.Note: Building application has been generated under 16016-10000-20105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56960	16041-10002-21889	7954 N MCLAREN AVE	91304	12	189B097   442	2014012020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.2153	-118.62433	07/11/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED. CHANGES INCLUDE REUSING FOUR EXISTING MODULES WITH MICROINVERTERS FOR NEW SOLAR SYSTEM. TOTAL SYSTEM SIZE IS ACTUALLY 5.95KWdc / 5.280KWac.(18)MODULES-CANADIAN SOLAR CS6K-275M(4)MODULES-SUNMODULE SW 250 MONO(22)MICROINVERTER-ENPHASE M250-60-2LL-S22Note: Permit is paid under PCIS#16041-90000-21889(((((PC AND PERMIT FOR CHANGE IN MODULES TYPES AND SIZES. NOW USING 275W DC MODULES AND ENPHASE M250 MICROINVERTER. NONSTANDARD PLAN. TOTAL KW OUTPUT = 52.28KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56961	14041-10000-07491	6859 N LAUREL CANYON BLVD	91605	2	183B165   471	2321026041	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.19565	-118.39671	FA - NEW PANEL TO REPLACE DAMAGED OLD PANEL (Fire Lite). 2 story. Devices are existing per applicant. Monitoring only. Fire department does not stamp. Building permit was in 1984. *2 STORY, TYPE V, 65X95 20 UNIT APT & SUBTERRANEAN PARKING. 22 PARKING SPACES REQ'D & PROVIDED. 20 STANDARD & 2 COMPACT. R-1/B-1 OCCUPANCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56962	16041-10000-18382	7920 N GLORIA AVE	91406	6	189B141   309	2206003023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	PIN	34.21439494	-118.47892676	PC for T-24 only. Remove HID fixtures and replace with new LED fixtures.  Total area: 6,133 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56963	19041-20000-42782	4529 W CURLEW CT	90065	14	159A217    48	5684002035	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	PIN	34.13196065	-118.23238392	PV1. INSTALL 7.20 KW DC GRID-TIED PV SYSTEM WITH (18) MODULES/MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56964	14041-20000-02649	19100 W SALT LAKE PL	91326	12	210B121   373	2718004025	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.27155	-118.54824	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56965	18041-10000-37051	13622 W VENTURA BLVD	91423	4	165B157   714	2373013029	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Approved	10/02/2018 12:00:00 AM	ADDRESS	34.14769	-118.43024	Energy plan check for a beauty shop T.I . Scope includes new lighting with a total area of 1040-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56966	19041-10001-03618	654 E VERNON AVE	90291	11	111B145  1229	4239003018	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	33.99767	-118.46818	**Fee expedite per applicantPV1 with ESS, Install 7.6 kW AC/ 6.175 kW DC roof-mounted solar array, with 13.5 kWh ESS, interconnect with 200A service panel. (19) modules, (1) 7.6 kW inverter, (1) 200A load center, (1) 13.5 kWh ESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56967	14041-10001-28828	1157 N GALLOWAY ST	90272	11	129B129   270	4423004022	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2014 12:00:00 AM			PC Approved	11/04/2014 12:00:00 AM	ADDRESS	34.05075	-118.522	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.85 KW DC ROOF-MOUNTED SOLAR ARRAY ON HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH BATTERY BACK UP.(14) MODULES: SOLARWORLD SW275(1) INVERTER: SCHNIDER E;ECTRICAL MPPT 80 600}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56968	14041-20001-34333	1156 N AMALFI DR	90272	11	129B133   167	4425012006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM			PC Approved	01/05/2015 12:00:00 AM	ADDRESS	34.05052	-118.50683	PV1. INSTALLING ROOF MOUNTED. 6.37 AC KW SYSTEM SIZE. (20) SUNPOWER SPR-X21-345(1) SMA SB70000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56969	18041-30001-00772	7999 WORLD WAY WEST	90045	11	090B157    17	4129026910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM			Verifications in Progress	05/31/2018 12:00:00 AM	ADDRESS	33.94186	-118.43203	Change to approved set by modifying the single line. All changes under clouded area only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56970	14041-20000-25855	13447 W CORNELIUS ST	91331	7	213B157   577	2523022014	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.27836	-118.42572	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.5KW INTERCONNECTED WITH MSP.(16) HYUNDAI M250 MODULES(16) ENPHASE MICROINVERTERS M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56971	11041-20000-01457	10823 N ZELZAH AVE Bld. A1 &-A2	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	04/27/2011 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.2668	-118.52366	Install outdoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56972	19041-20000-17192	515 S FLOWER ST 8TH FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI to (E) commercial tenant space in highrise building.  Plan check for energy - 11,100 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56973	12041-20000-04838	6301 N OWENSMOUTH AVE 11th floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM			PC Approved	03/02/2012 12:00:00 AM	ADDRESS	34.18467	-118.60176	T24 lighting plan check for a portion of the 11th floor.  Emergency lighting was not affected.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56974	18041-10000-44011	6390 W DE LONGPRE AVE	90028	13	147A187   290	5546016002	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Apartment			02/12/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	04/30/2021 12:00:00 AM	ADDRESS	34.09602	-118.32852	PC FOR POWER AND ENERGY FOR A 20 STORY TRANSIENT OCCUPANCY RESIDENTIAL STRUCTURE HIGHRISE BUILDING. 193 APPARTMENTS. SCOPE INCLUDES NEW (4000A) DISTRIBUTION EQUIPMENT CONNECTED TO EXISTING 4000A SERVICE PERMITED UNDER (17041-10001-24720 REFERENCE ONLY), PANELS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA IS 82333 SQ.FT - UNIT PANELS ARE SERIES RATED WITH ASSOCIATED FEED ONLY ALL OTHER EQUIPMENT IS FULLY RATED. B# 16010-10000-05333podium and basement parking under separate permit (15010-10000-04706).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56975	18041-10000-21613	14127 W CHANDLER BLVD	91401	4	171B153    36	2245025017	RS-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.16872	-118.44102	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 9.75KVA SYSTEM. CONSISTING OF 39 PANELS WITH P250 MICROINVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56976	17041-10001-24569	18620 W VENTURA BLVD	91356	3	174B121   644	2161015013	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.16987	-118.53933	"[[6/29/18 CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA ""3"" CHANGES. ISTALLATION OF A 500KVA TRANSFORMER BETWEEN MAIN SWITCHGEAR AND DP1 ]]] PC power and energy for LA fitness TI. PC includes new 1600A service, three new panels, new circuits and equipment. Total affected area is 24536 sqft. Building # 17016-10000-16949."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56977	11041-20000-01644	4920 N TOPANGA CANYON BLVD	91364	3	168B101   431	2171016042	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	03/16/2011 12:00:00 AM	ADDRESS	34.15747	-118.60559	Plan check for T24 Energy tenant improvement to existing retail/beauty salon center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56978	18041-10000-32109	11938 W PICO BLVD	90064	11	123B149  1015	4259039012	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.02973	-118.4491	Install a new Fire Alarm System with 22 Devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56979	10041-10000-01577	10250 W SANTA MONICA BLVD #56	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM			Corrections Issued	03/01/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. for existing commercial space (Intimacy)  Install new lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56980	16041-20000-42706	735 W 7TH ST G-735	90017	14	129A209   265	5144029***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.04867	-118.25847	TI to (E) commercial restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56981	18041-20001-28708	17036 W CALAHAN ST	91325	12	198B133   598	2692019004	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Issued	08/21/2018 12:00:00 AM	ADDRESS	34.2363	-118.5038	08/21/2018 Changes to an approved set of plans. System size is now 9.6 kWdc/8.8 kWac-CEC and consists of (2) inverters, (30) modules, and (1) load center. Module model has changed.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 8.775 kWdc/8.1 kWac-CEC and consists of (2) inverters, (29) modules, and (1) load center. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56982	12041-10000-11639	915 W WILSHIRE BLVD	90017	9	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.05069	-118.2599	Plan check for energy and emergency lighting. High rise commercial building. 1760 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56983	15041-10000-23577	1100 S SAN PEDRO ST A-13	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.03515	-118.25194	PLAN CHECK FOR ENERGY ONLY FOR DIVIDING EXISTING SINGLE RETAIL INTO TWO (2) RETAIL SUITES WITHIN THE EXISTING RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56984	16041-20000-07486	20640 W COVELLO ST	91306	3	186B109   408	2113007007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.20705	-118.5835	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (33) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
56985	13041-20000-28534	6060 W WILSHIRE BLVD BASEMENT	90036	4	135B177   526	5086009014	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.06273	-118.36103	TI for basement level of a 3-story museum, conversion of storage space to office.  Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56986	12041-20000-27839	333 S HOPE ST Ste 3700	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/19/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	T.I.  Office Suite # 3700.  Existing commercial place.  Modification to existing lighting.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56987	17041-10000-20350	8240 N LANKERSHIM BLVD	91605	6	192B169   512	2311001011	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.22052	-118.38755	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
56988	17041-20000-24636	13764 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.30935	-118.43315	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT & CHG OF USE TO RESTAURANT. 1371 SQFT. SUITE 152 BUILDING PERMIT # 17016-20000-20044	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56989	14041-20000-02595	20911 W ARCANA ROAD	91364	3	166-5A109 201	2172022070	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Expired	03/07/2016 12:00:00 AM	ADDRESS	34.14939	-118.58885	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
56990	15041-10000-23800	7121 W SUNSET BLVD	90046	4	147B181   636	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.09815	-118.34508	Full plan check for a medical office ( Chiropractic) TI; Scope includes new lighting, equipment and receptacles. Total area is 828-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56991	17041-20000-09405	2117-2121 W SAN FERNANDO ROAD	90065	1	148-5A215  23	5442004005	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.10282	-118.23719	Installation of (N) 800A 120/240V 3ph-4w service for (E) commercial building.  Reconnection of (E) panels and loads to new service equipment.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56992	14041-10000-21694	9301 N TAMPA AVE #144	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPORVEMENT. CHANGE OF USE FROM RETAIL TO RESTAURANT. 3865 SF, WITH OUT DOOR SEATING AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56993	11041-10001-20643	1030-1038 E LAKE ST BLDG 36	90291	11	111B145   346	4243003044	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/23/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.00215	-118.46028	LINCOLN PLAZA APARTMENT BUILDING PROJECT.(((((((((((((((((((((((((((((((((   7-23-14   Addition of 3 E.V. charginger.   M.Z.  )))))))))))))))))))))))))))	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56994	16041-10000-40663	6655 N ETIWANDA AVE	91335	3	180B125   225	2125017001	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Apartment			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.19202	-118.5318	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 5550 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56995	10041-10000-02568	14955 W ROXFORD ST	91342	7	228B145    54	2502002061	(Q)C1-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	Public Safety Only			02/12/2010 12:00:00 AM	02/12/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.32308	-118.46054	New Fire Alarm Plan.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56996	14041-20001-04622	1965 N CANYON DR	90068	4	150A191    24	5586023032	R1-1-HPOZ	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.10715	-118.31711	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING 2 CENTRAL INVERTERS. TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
56997	13041-20000-24620	990 W 190TH ST STE 450	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM			PC Approved	09/09/2013 12:00:00 AM	ADDRESS	33.85813	-118.29505	Plan check for energy and emergency lighting. Commercial low rise. Suite 450. Nagano Morita LLP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56998	16041-10000-22691	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC FOR ENERGY. TENANT IMPROVEMENT: CONVERT  EXISTING RESTAURANT SPACE  TO OFFICE SPACE. TOTAL AREA 14085 SQ FT.B # 16016-10000-13493.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
56999	14041-20000-04271	1537 N NORFOLK ST 5th Fl	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.06138	-118.20223	T.I. to USC Doheny Eye Institute (partial of the fifth floor).  Replace X-Ray equipment and add subpanels.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57000	19041-10000-45864	15027 W KESWICK ST	91405	6	189B145   626	2209037047	MR2-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.21042	-118.45999	PC FOR ENERGY ONLY. SCOPE INCLUDES NEW INDOOR/OUTDOOR LIGHTING. TOTAL AFFECTED AREA IS 23655 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57001	14041-10000-04569	1004 S CROCKER ST	90021	14	124-5A211 256	5132010050	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.0344	-118.25047	"PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 676 SQFT. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57002	14041-20000-15197	5823 N KEOKUK AVE	91367	3	174B113    66	2151002028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Expired	07/20/2016 12:00:00 AM	ADDRESS	34.17656	-118.57628	PV1.  Install 5.1 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57003	15041-20000-24708	2901 S CENTRAL AVE	90011	9	117A209   108	5128021001	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.01561	-118.25643	Plan check for change of use from warehouse to office and service upgrade 800A. Total area: 10,001sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57004	15041-20001-33299	1117 S NORMANDIE AVE	90006	10	129B193   703	5078019004	R4-1VL	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.0503	-118.3002	PV1, roof mounted solar 6.39 kW AC, (27) modules: Q.PRO- BFR-G4 260, (1) inverter: Solar Edge -SE600A-US, (27) solar edge power optimizer P300	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57005	15041-10000-01465	1061 S OXFORD AVE 1-9	90006	10	129B193   601	5080009026	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.05104	-118.30766	Plan check for fire alarm installation inside, on the roof and parking structure.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57006	18041-10000-16841	16000 W STRATHERN ST	91406	6	189B141    74	2206006022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.21559	-118.48176	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57007	12041-10000-09900	11957 W SANTA MONICA BLVD #101	90025	11	126B145   505	4263029053	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.04143	-118.46175	"PLAN CHK IS FOR TITLE 24CHANGE OF USE FROM RETAIL TO MASSAGE PARLOR WHERE ANY PERSON WHO PROVIDES MASSAGE SERVICES AT THIS PREMISE SHALL BE CERTIFIED AS A MASSAGE THERAPIST OR MASSAGE PRACTITIONER PURSUANT TO CALIFORNIA BUSINESS AND PROFESSIONS SECTION 4600 ET ESQ. NO PATIENT CARE PROVIDED""COMPLY WITH DEPARTMENT ORDER effective date01/19/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57008	15041-10000-34769	1570 W 226TH ST	90501	15	045B193   156	7347011011	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	33.8212	-118.30609	PV1, INSTALL 5.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(18) MODULES: LG MONO-X 280-S C-B3(1) INVERTER: FRONIUS PRIMO 3.8-A 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57009	13041-10000-30037	2110 W 7TH ST	90057	1	132A203   100	5141018002	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Info Complete	11/27/2013 12:00:00 AM	ADDRESS	34.0565	-118.27737	PLAN CHECK FOR POWER ONLY. SERVICE UPGRADE FROM 400 AMPS TO 600 AMPS. TITLE 24 ENERGY PLAN CHECK PREVIOUSLY DONE UNDER 13041-10000-20742. CARLS JR RESTAURANT. Permit is existing this plan check only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57010	11041-10000-25542	6101 N VARIEL AVE	91367	3	177B105    52	2149005045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.18081	-118.59299	T.I. to convert an existing Office/Warehouse building into Panavision film equipment for equipment repair and testing.  New services for 2000A and 2500A, 774 new circuits, new panels and equip.  131,000 square feet building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57011	14041-10000-30016	672 E 120TH ST	90059	15	084B205  1197	6086026021	RD2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Expired	03/30/2017 12:00:00 AM	ADDRESS	33.9235	-118.26268	PV 2 ROOF MOUNTED SOAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 3 KW 7 MODULES WITH 1 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57012	18041-20000-10316	11320 W MAGNOLIA BLVD	91601	2	171B173   672	2353002008	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.16469	-118.37817	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57013	19041-20000-20653	1319 S ORANGE GROVE AVE	90019	10	129B177   213	5086004009	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			05/31/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	12/15/2021 12:00:00 AM	ADDRESS	34.05271	-118.36531	Plan check for power and energy. Work includes 1,200-amp service and a total lighting area of 30,131 sq. ft.Note: Building application has been generated under 18010-30000-02518	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57014	11041-20000-23123	4331 N NATOMA AVE	91364	3	166-5A111 102	2174010017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04, 1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2011 12:00:00 AM	11/10/2011 12:00:00 AM		Permit Finaled	11/21/2011 12:00:00 AM	ADDRESS	34.14919	-118.58018	Plan check roof mounted 10.56KW Photovoltaic system  single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57015	16041-20000-19184	14500 W OLIVE VIEW DR THE ELM	91342	7	228B149    20	2502024024	QRD1.5-1, RD1.5-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	Apartment			06/01/2016 12:00:00 AM			Reviewed by Supervisor	07/13/2016 12:00:00 AM	ADDRESS	34.32399	-118.44867	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(62) CANADIAN CS6P255P MODULES(2) SMA INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57016	19041-20001-19840	6213 E BURWOOD AVE	90042	14	157-5A231  32	5483022019	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	34.12757	-118.18416	Revision to approved plan.  Energy storage system location change. (((Install 13.5 kWh energy storage system.  125A load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57017	16041-10001-38001	4061-4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.99055	-118.44379	Changes to an approved set of plans. All changes are clouded under delta 1. changes include adding new sump pumps, adding EV chargers, revising panel schedules, revising single line diagram, and revising load calculations. PC FOR POWER AND ENERGY FOR A MIXED USED BUILDING (49 UNITS)SCOPE INCLUDES NEW SERVICE (4000A /480V)B#16010-10000-04167	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57018	14041-20000-29376	975 S FOSTER DR	90048	5	132B173   346	5088007033	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.05914	-118.36999	$0 permit fee due to senate bill 1222 from 2012PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 10.32kW.48 EnPhase M215 microinverters and 48 260W pv modules across 3 strings (16+16+16).Derating the main breaker from 200A to 175A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57019	16041-10001-30987	5760 W ARBOR VITAE ST	90045	11	093B169   344	4125020014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	33.9525	-118.38238	UPDATED PLAN TO SHOW NEW FEEDER SOURCE AND FEEDER ROUTING. NO CHANGE TO T24. RESTAMPING PLANS. PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57020	14041-10001-07912	1829 N LEMOYNE ST	90026	13	142-5A209  87	5420012003	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.08554	-118.25483	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(16) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57021	17041-30001-39696	1301 S OCEAN FRONT WALK #1	90291	11	108A143   398	4226006001	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	33.98842	-118.47485	Plan check for Title 24 only in restaurant Joe's Pizza. Total area: 241 sq ftPlan check onlyNote: permit shall refer to 17041-30000-39696	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57022	14041-10000-23103	7640 N BURNET AVE	91405	6	186B145    61	2209035005	P-1, [Q]CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.20959	-118.46279	PLANCHECK FOR T24 ENERGY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. 7246 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57023	14041-20000-07581	13129 N CONSTABLE AVE	91344	12	222B133    51	2602002009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.30858	-118.50329	PV1 CENTRAL INVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 12kw DC/ 10.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57024	16041-10000-14135	6220 N TOPANGA CANYON BLVD K9090	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.1841	-118.60553	Title 24 Plan check only for a small TI kiosk located in outdoor mall. Space number 9090. New power receptacles and new lighting. Floor area of 238 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57025	13041-10000-18221	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Issued	11/18/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	DISTRIBUTION BOARD REPLACEMENT ON 4TH FLOOR OF THE BEVERLY CENTER. One-for-one replacement of Distribution board associated with MSAA, MSBA, MSCA , MSDA, DSAA,  DSBA, DSBB, DSDB, EDUA, EDRB, EDRC, EDRD. See 13041-10000-27554 for Generator related issues.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57026	19041-10000-46900	9214 N HAYVENHURST AVE	91343	12	198B137   721	2676022003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	05/28/2020 12:00:00 AM		Permit Finaled	12/09/2020 12:00:00 AM	ADDRESS	34.23794	-118.4936	$0 PERMIT FEES DUE PER AB 1414. PV1, NEW ROOFTOP SOLAR SYSTEM, SYSTEM SIZE IS 14.5KWac/15.7KWdc, SCOPE OF WORK IS 50 MODULES (Q-CELL 315) WITH MICROINVERTERS (IQ7PLUS) LEADING TO A COMBINER PANEL. MAIN BREAKER HAS BEEN DERATED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57027	19041-20000-32432	4402 N LEDGE AVE	91602	4	165B177   353	2424005014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	12/28/2019 12:00:00 AM	ADDRESS	34.1506	-118.35694	Install 27 kWh energy storage system and associated distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57028	19041-20000-52302	818 W 7TH ST #980	90017	14	129A209    60	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.04895	-118.25943	Plan check for Title 2 Energy only, new lighting. Total area: 5773 sq ft. B#19016-10000-30422	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57029	19041-10000-36511	233 S ANITA AVE	90049	11	129B141    57	4405030004	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.05351	-118.48225	PV1, NEW ROOFTOP MPUNTED SYSTEM, SYSTEM SIZE IS 11.55 KWdc/11.2 KWac. SCOPE OF WORK IS 35 MODULES (PANASONIC VBHN330SA17E) WITH MICRO INVERTERS (ENPHASE IQ7X-96-2-US), LEADING TO A ENPHASE COMBINER BOX, LEADING TO A MAIN BREAKER DERATE (PERMIT  HAS BEEN PULLED FOR THE BREAKER DERATE).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57030	14041-10000-23364	15410 W LEADWELL ST	91406	6	186B145   656	2222022005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.20381	-118.46877	5.94KW roof-mounted system including (27) Kyocera KD255GX  modules, (2) PVI-3.8.OUTD inverters interconnect through a load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57031	16041-10000-20668	134 W 55TH ST	90037	9	108B201   756	5101030023	R2-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.99229	-118.27521	PV SYSTEM WITH 17 MODULES. USING MICROINVERTERS ENPHASE M215. TOTAL 3.65KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57032	19041-20001-47294	1320 N HOOVER ST	90027	4	147A201   196	5430032015	R2-1XL	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.09632	-118.28393	Revision to approved plans.  Approval for design drawings that incorporate (E) 3.8 kW AC PV system.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57033	15041-10000-43935	8532 W CASHIO ST	90035	5	129B173   569	4303032005	R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM			Reviewed by Supervisor	01/19/2016 12:00:00 AM	ADDRESS	34.05076	-118.37735	Full plan check for a 4 story 7 unit apartment with basement garage; Total 4-typical units. Title-24 is based on 2013 Energy code.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57034	14041-20000-28043	1230 S OLIVE ST	90015	14	126A207   209	5139024016	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.03857	-118.26278	NEW 7 STORY 361 UNIT APARTMENT BUILDING 5000AMP SERVICE WITH TWO UNDERGROUND PARKING LEVELS.  VARIANCE FOR FILE ALARM HAS BEEN FILED 5/6/15NOTE TO PLAN CHECKER:ADDITIONAL EQUIPMENT CHARGE WILL BE REQUIRED FOR (1) SEVICE AND (361) SMOKE ALARMS DUE TO PREMADE CHECK FOR SUBMITTAL CHERGE.FINISHEDDUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57035	17041-10000-02863	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	FULL PC FOR POWER AND ENERGY. APPROX.  TENANT IMPROVEMENT  FOR  AIRLINE TENANTS AT LAX TERMINAL 6. SCOPE INCLUDES NEW CIRCUITS, NEW LIGHTS, AND RECEPTACLES. NEW CONNECTED LOAD >400A TOTAL AFFECTED AREA IS 21045 SQ. FT. B#16016-10000-28397	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57036	14041-20000-17787	4262 N MOONCREST PL	91436	5	165B133   239	2292003013	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.14937	-118.50399	PV1.  Install 6.04 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57037	17041-10000-27198	4550 N VAN NUYS BLVD C	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	PC for power and energy for first time tenant juice bar. PC for two new panels, new circuits and new equipment. Total sqft 1444 sqft. Building # 17016-10000-12031.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57038	15041-10000-11798	11111 W SANTA MONICA BLVD SUITE 650	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.04771	-118.44481	ADDING NEW LIGHTING AND NEW CONTROLS TO AN (E)  HIGH RISE OFFICE BUILDING . PC FOR ENERGY ONLY. SCOPE OF WORK ON SUITE 650. TOTAL SQ FT. 2194	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57039	19041-10000-42262	1422 N EL BOSQUE CT	90272	11	138B117   164	4431026016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.07499	-118.55608	(E-PLAN)NEW ROOF-MOUNTED PV1 (12.73KW DC; 11.02 KW AC ) SYSTEM INCLUDES 38 MODULES, ENPHASE IQ7+ MICROINVERTER (290 VA), 2 ENERGY STORAGE SYSTEMS (TESLA POWERWALL) CONNECTED TO AN EXISTING 225 AMP SERVICE.Fees $3.97 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57040	18041-20002-14334	6822 W PARSONS TR	91042	7	207B201    23	2553014002	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	9800.26	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	34.26631	-118.28268	06/19/2018 Changes to an approved set of plans. PV system strings have been revised. Equipment count has remained the same. *****Previous Work Description*****Note: $0.00 permit fee due to CA Senate Bill 1222PC for 12.42kW(ac)/17.55kW(dc) system for SFD. Installing 54 modules with microinverters with combiner box.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57041	14041-20000-34920	10924 N KEY WEST AVE	91326	12	210B117   312	2718021005	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.26878	-118.55357	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(23) CANADIAN SOLAR CS6P-250P MODULES(1) SOLAR EDGE SE5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57042	17041-20001-28856	8932 N WOODMAN AVE	91331	6	195B153   373	2640016027	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.23211	-118.43779	11/15/2018Changes to an approved set of plans.  update plans to reflect Fault current report and AIC ratings.this is plan check only.    ((((Plan check for power and energy. Project site is an existing dental office. Project scope is a tenant improvement. Total lighting area = 10,370 sq. ft.Note: Building application has been generated under 17016-20000-23488))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57043	17041-10001-07538	20929 W VENTURA BLVD Building C	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	"[[7/31/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING FEEDER SIZES AND BREAKERS FOR FUTURE PANELS TO THE ""MSC"" MAIN SWITCHBOARD ]]]]Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 1200-amps.Note: Building application has been generated under 16016-20000-22114"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57044	17041-10000-00876	333 S HOPE ST #3625	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 only in existing office space high-rise building. Total area: 2183 sq ft. Suite # 3625	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57045	10041-20000-16242	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	C2-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	08/18/2010 12:00:00 AM		Permit Finaled	02/08/2012 12:00:00 AM	ADDRESS	34.04338	-118.26581	Plan check for T-24 Energy for Staples Center (Nike Vault). Replacing lighting fixtures. Existing T-24 mandatory measures and circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57046	19041-20000-22210	22135 W ROSCOE BLVD LOT #29	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 29.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57047	14041-20000-21827	7500 N VINELAND AVE	91352	2	186B173   507	2410001031	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Apartment			08/13/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.20664	-118.37007	12 units apartment building 3 stories fire alarm variance on hand	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57048	12041-10000-19590	225 S GRAND AVE	90012	14	132A211    60	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Apartment			08/20/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.05388	-118.25078	NEW HIGHRISE MIXED USE APARTMENT & COMMERCIAL (RESTAURANT) BUILDING OVER PRIVATE PARKING GARAGE. 22 STORIES W/ 1 LEVEL BASEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57049	13041-10000-28406	110 S FAIRFAX AVE A14	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.07371	-118.36119	TITLE 24 ENERGY PLAN CHECK ONLY.  BLAZE RESTAURANT. NO CHANGE IN OCCUPANCY. EMERGENCY LIGHTING. 1,127SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57050	10041-10000-17298	5905 W WILSHIRE BLVD	90036	4	135B177   424	5508016901	PF-1D	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Finaled	02/11/2011 12:00:00 AM	ADDRESS	34.06282	-118.35793	Ti in LA County Museum. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57051	10041-20000-09336	2709 E MEDIA CENTER DR	90039	1	150B213  3653	5442032001	[Q]M1-1-CDO, [Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM			PC Approved	06/15/2010 12:00:00 AM	PIN	34.11096076	-118.24539883	lighing and power in charter school. This plan check is for title 24 energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57052	14041-10000-03647	7940 N LLOYD AVE	91605	2	189B157   458	2303003023	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.21514	-118.42057	PV1, roof-mounted solar installation, to interconnect with (E) 200A main service. system sized @ 7 kW DC, with (28) modules & optimizers (OP250-LV) , (1) SE6000A-US solar edge inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57053	14041-10000-03830	350 S FIGUEROA ST	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Public Safety Only			02/11/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Expired	03/09/2016 12:00:00 AM	ADDRESS	34.05438	-118.2549	REPLACING FIRE ALARM PANEL ;NEW PANEL WILL BE COMPATIBLE WITH EXISTING FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57054	19041-10001-03384	8533 W HARGIS ST	90034	10	123B169   717	5065007029	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.03329	-118.37956	"DELTA ""1"" CHANGES TO APPROVED PLANS FOR MOVING PV PANELS. <<<Plan check for a 5.2KW AC roofmounted system with (14) modules and (1) inverter interconnecting through the service panel.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57055	14041-10000-03939	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.24143	-118.56249	NEW INSTALLATION  FOR  AN  AUTOMATIC FIRE SUPPRESSION SYSTEM. LOW VOLTAGE WIRING IN  CONDUITS . 3 CHAMBERS IN THE SYSTEM. 46 DEVICES , 2 PANELS. ( SUPPRESSION PANEL AND CONTROL PANEL)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57056	13041-10000-20717	9745 N LAUREL CANYON BLVD SUITE B	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.24644	-118.41942	TITLE 24 PLAN CHECK ONLY. CHASE BANK. TENANT IMPROVEMENT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. 1573 SQFT. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57057	13041-10000-34861	500 W WORLD WAY TERMINAL-5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	T24 PART 6 ENERGY LIGHTING ONLY; PROJECTED AREA IN SCOPE OF LIGHTING WORK IS APPROX. 1215 SQ FT. FOR LOBBY/MAIN ENTRY & ELECTRICAL ROOM AREAS. SCOPE OF WORK < 400A. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57058	14041-10000-27710	2750 W BROADWAY	90041	14	163-5A219 120	5682036029	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.14301	-118.22512	CONVERT 1650 SF PORTION OF (E) MEDICAL OFFICE TO NEW DENTAL CLINIC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57059	13041-10000-25541	811 W 7TH ST #600	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.04908	-118.25911	TITLE 24 PLAN CHECK ONLY. HIGHRISE. WORK ON THE 6TH FLOOR. 1615 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57060	19041-10000-18792	3484 W SAN MARINO ST	90006	10	132B193  1080	5080008019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.05433	-118.30862	T-24 PLANCHECK FOR A TI OF AN EXISTING RETAIL STORE. (SUBDIIVDE (1)-TENANT INTO (3)-TENANTS. NEW RESTROOM) SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, CONTROLS AND RECEPTACLES. TOTAL CONNECTED LOAD IS LESS THAN 400A. TOTAL AFFECTED AREA IS 3563 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57061	19041-20000-32059	20803 W ACORN CIR UNIT #164	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM	ADDRESS	34.2945	-118.58668	PV1.  Install 3.15 kW roof mounted PV system.  (9) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57062	19041-20000-38038	17512 W OSBORNE ST	91325	12	195B129   158	2768026007	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	04/11/2022 12:00:00 AM	ADDRESS	34.23334	-118.51636	PV1.  Install 11.34 kW roof mounted grid tied PV system.  (36) modules with 7.6 and 3.8 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57063	15041-10000-01594	5933 W CENTURY BLVD ste C	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	Energy plan check for a restaurant (pizza ) T.I with new circuits and a panelboard; Circuits are paid under separated permit #: 15041-10000-07603.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57064	14041-10001-13895	13604 W SHERMAN WAY	91405	2	183B157    75	2328008008	(T)(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			04/02/2015 12:00:00 AM			Reviewed by Supervisor	04/13/2015 12:00:00 AM	ADDRESS	34.20102	-118.4293	PC FOR POWER AND T24. CHANGES  TO THE APPROVED SET AOF PLANS. REVISED TITLE 24 FOR CHANGING FIXTURES AND CALCULATIONS, CORRIDOR LIGHTING FOR 2, 3, 4 AND 5TH FLOOR. TOTAL AREA 12000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57065	15041-10000-13242	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Relocation of existing 6 kVA transformer and panel to serve new lighting and walk-in cooler.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57066	12041-10000-26992	8459 W MELROSE PL	90069	5	141B173   422	5528001034	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.08374	-118.37513	TENANT IMPROVEMENT TITLE 24 AND EMERGENCY LIGHTS. 1940 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57067	12041-20000-31078	18211 W VENTURA BLVD	91356	3	171B125   273	2160014010	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.16621	-118.52912	Plan check for energy and emergency lighting. Stand alone building. Office Depot. 7460 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57068	15041-10001-29072	1120 S GRAND AVE	90015	14	126A207    60	5139020024	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			09/28/2016 12:00:00 AM			PC Approved	10/17/2016 12:00:00 AM	ADDRESS	34.04095	-118.26231	09/28/2016 Plan check for power and energy changes to an approved set of plans. Changes include  size of the transformer from 225 KVA to 300KVA and 500KVA, changes to lighting layout. All changes under delta 6.** This is Plan Check only, Permit shall be issued under the master PCIS# 15041-10000-29072** ((((((((New 41 story apartement  building, 536 units. PC for Power and Energy. FA variance on file.Building app. under 13010-10000-03761 architect to update building submittal at a later time.**Fees per applicant, additional fees may apply.)))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57069	13041-10000-31529	8419 S TRUXTON AVE	90045	11	096B165   219	4107031007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	33.962	-118.3936	PV1, Install 2.75 kW DC roof-mounted photovoltaic system interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US., power optimizer, and 11 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57070	14041-10000-35599	111 E UNIVERSAL HOLLYWOOD DR 28th Floor	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	34.13855	-118.36112	TI of the 28th floor of a commercial highrise office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57071	14041-10000-30377	11460 N DORAL AVE	91326	12	213B121   440	2822031025	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.28009	-118.54884	6.54 kW DC roof mounted PV1 system. System consists of (20) 327 W modules and (1) 6000 W rated (transfomer-less) inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57072	14041-20000-12062	17336 W RANCHO ST	91316	5	168B133   347	2290021016	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.1562	-118.51103	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 12KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING 2 INVERTERS. INTERCONNECT TO 400A SERVICE.Fee is $0.00 due to State Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57073	17041-10000-15295	10866 W ART ST	91040	7	201B173   268	2542025010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.24841	-118.36746	PC for PV1 roof mounted in a single family home. Adding new central inverter to existing system. The new inverter is rated at 3 KW, (12) new panels. Total system size: 14.4 KW, (47) solar panels.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57074	15041-10000-27973	6201 W HOLLYWOOD BLVD SUITE 116	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC FOR ENERGY ONLY ON EXISTING COMMERCIAL (NAIL SALON) 1-STORY BUILDING. SCOPE INCLUDES NEW PANELS AND LIGHTING. TOTAL AREA IS 1558 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57075	13041-20000-03378	10570 N EL DORADO AVE PV1	91331	7	207B157   836	2620004018	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Expired	03/17/2015 12:00:00 AM	ADDRESS	34.26247	-118.421	INSTALL ROOF MOUNTED PHOTOVOLTAIC SYSTEM 4.2 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57076	10041-20000-15449	1551 N WILMINGTON BLVD	90744	15	036B201   416	7414027030	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.00	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	02/07/2012 12:00:00 AM	ADDRESS	33.79401	-118.2753	Plan check T-24 Energy for office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57077	16041-10000-26095	953 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.08865	-118.34299	New Methane Mitigation Design Level IV on a 8-Story Media Production Office Building over 2 level subteranian parking space.  (1) Panel    (19) Devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57078	17041-20000-17297	5012 N MAMMOTH AVE	91423	4	171B157  1013	2269002020	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Issued	06/05/2017 12:00:00 AM	ADDRESS	34.16154	-118.43229	Plan check for roof-mounted solar pv system with dc coupled battery backup for SFD.6kW ungrounded system. (18) 325W pv modules. (1) 5kW Tesla Powerwall backup battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57079	11041-10000-19781	2311 S FAIRFAX AVE	90034	10	123B173  2062	5064029907	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.037	-118.36902	INSTALL A NEW 45KW PV SYSTEM ON THE ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57080	16041-20000-16607	7066 N MIDDLESBURY RIDGE CIR	91307	12	183B089   215	2028042014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.19922	-118.6482	Plan check  PV roof mounted system addition of 3.0kW to existing 5.0kW. Addition of 8 modules and 1 inverter(3.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57081	07041-10003-12960	1724 N HIGHLAND AVE Club House	90028	13	148-5A185  63	5547011023	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM			PC Info Complete	02/17/2010 12:00:00 AM	ADDRESS	34.10238	-118.3385	Expansion of the club house area approximately 375 square feet of gym area.  T24 lighting to be done for the entire club house portion for compliance purposes.  Work associated with Delta 7 modifications only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57082	12041-20000-00765	16605 W OLDHAM ST	91436	5	162B137   106	2291014032	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	ADDRESS	34.14305	-118.49491	Photovoltaic system on roof of single family dwellling using Enphase inverter model M215.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57083	11041-10000-01371	10250 W SANTA MONICA BLVD # 113	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM			PC Approved	01/24/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	TI - REMODEL EXISTING RETAIL SPACE INCLUDING; CEILING, PARTITIONS, STOREFRONT (LIGHTING & M.E.P. WORK). PERMITS WERE OBTAINED ON 11041-90000-05362 AND 11041-90000-05199  PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57084	17041-20000-41825	11250 W CANTON DR	91604	2	159B173   255	2377014021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Expired	03/23/2024 12:00:00 AM	ADDRESS	34.13372	-118.37807	PV1.  Install roof mounted PV system sized 11.4kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57085	15041-20001-03067	12491 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	03/01/2015 12:00:00 AM	ADDRESS	33.97895	-118.41081	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57086	14041-20000-28141	601 W 5TH ST	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for energy only. TI for office on 11th floor of existing office building (suite #1100). New lighting (incl. emergency). 4,645sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57087	16041-10003-33058	20600 W VENTURA BLVD	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM			PC Approved	09/08/2017 12:00:00 AM	ADDRESS	34.16715	-118.58204	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 2. CHANGE FEEDER LENGTHS AND LOCATION ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57088	10041-10000-15067	1330 E FACTORY PL D&E	90013	14	126A215   231	5164008032	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	10/29/2010 12:00:00 AM	ADDRESS	34.03898	-118.23515	TI IN AN EXISTING COMMERCIAL BUILDING. PLAN CHECK FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57089	15041-10000-32232	4846 W PICO BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.048	-118.342	T.I. FOR YOSHINOYArelocate panels and new circuits and luminairesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57090	10041-10000-09204	14006 W RIVERSIDE DR # 63	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	06/08/2010 12:00:00 AM		Permit Finaled	08/26/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	TENANT IMPROVEMENT IN RETAIL SPACE AT THE SHERMAN OAKS FASHION SQUAREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57091	17041-20000-02157	23001 W MULHOLLAND DR	91364	3	165B097    72	2074038001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Issued	02/02/2017 12:00:00 AM	ADDRESS	34.15169	-118.62644	Plan check for a PV1 roof-mounted PV system. System size is 11.2 kWac and consists of (40) modules, (40) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57092	14041-10001-03315	1000 S GRAND AVE	90015	14	127-5A209 242	5139009008	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			08/12/2015 12:00:00 AM			PC Approved	08/12/2015 12:00:00 AM	ADDRESS	34.04258	-118.26079	8/12/2015CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 4.  CHANGES INCLUDE ORIENTATION TO THE SLD LAYOUT.  THIS IS PLAN CHECK ONLY. PLANCHECK FOR POWER AND ENERGY FOR A 273 UNIT APARTMENT.building p# 13010-10001-03605, 13010-10001-03605:7-story Mixed Use Building , 271 unit apt over 2 live/work unit & Retail (Shell only).  The building includes 5 stories of Type IIIA residential apartment on top of 2 stories on-grade Type IA  residential, retail, assembly, parking and 3 levels of Type IA subteranean parking.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57093	15041-10001-07363	3273 W CASITAS AVE	90039	13	153B209   393	5436002023	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.11638	-118.25202	CHECKING FOR CHANGES TO APPROVED SET OF PLANS. ADDED SCOPE OF WORK NOTED DELTA 1 ON PLANS. ADDED LIGHTING AND RECEPTACLES FOR BUILDING B AND 1ST FLOOR OF BUILDING A. PC FOR 2008 ENERGY CODE DUE TO BUILDING SUBMITTAL. THIS IS CONTINUED CONSTRUCTION FROM BUILDING PERMITS CORE AND SHELL 2014	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57094	13041-10000-06802	1724 W EL REY ROAD	90732	15	015B193    91	7559023005	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2013 12:00:00 AM	03/15/2013 12:00:00 AM		Permit Expired	04/13/2015 12:00:00 AM	ADDRESS	33.73978	-118.31355	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE STORY HOME USING MICROINVETER STANDARD PLAN. SYSTEM SIZE IS 4.32 KW USING 20 MODULES AND MICROINVETERS AND A LOAD CENTER. [INVERTER: ENPHASE # M215 |||| MODULES: CENTRO SOLAR # E250B] (1 STRING OF 14 AND ANOTHER OF 6) LOCATION OF PHOTOVOLTAIC ARRAYS ARE APPROVED BY THE FIRE DEPARTMENT ON 3/16/13 ON SEPERATE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57095	18041-20000-00515	2414 E MICHIGAN AVE	90033	14	127-5A223  81	5180002023	[Q]R4-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Apartment			01/05/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Closed	04/26/2018 12:00:00 AM	ADDRESS	34.0449	-118.20834	PV2.  Reinstallation of 7.695 kW DC rated PV system for reroofing project.  (27) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57096	15041-10000-22629	3825 N MISSION ROAD	90031	1	136-5A227  10	5211011030	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.07009	-118.19958	PC FOR NEW FIRE SAFETY SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57097	13041-20000-36076	7349 N RUTHERFORD HILL DR	91304	12	186B089   522	2027043014	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	PIN	34.20459046	-118.65283254	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTALSYSTEM SIZE 6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57098	14041-20000-10139	20300 W TAU PL	91311	12	207B113   245	2707017015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.2609	-118.57574	New roof mounted PV system with Optimizer and transformerless inverters.  System size 4.75KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57099	18041-10000-38772	18255 W VICTORY BLVD	91335	3	180B125   648	2124001902	OS-1XL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1329.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.18677	-118.53094	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57100	17041-20001-24333	20257 W JUBILEE WAY	91326	12	216B113     9	2701002069		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM			PC in Progress	07/23/2017 12:00:00 AM	ADDRESS	34.28352	-118.57523	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.48 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57101	19041-20000-52095	7539 W SUNNYWOOD LANE	90046	4	156B177   176	5570034013	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	03/12/2020 12:00:00 AM		Issued	03/12/2020 12:00:00 AM	ADDRESS	34.12618	-118.36184	PV1.  INSTALL 10.8 KW DC/9.778 KW AC CEC PV SYSTEM AND 20 KWH ENERGY STORAGE SYSTEM.   (30) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, A LOAD CENTER,  AND A 8 KVA BATTERY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57102	11041-10000-12743	5758 W CENTURY BLVD virgin-atlantic	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/27/2011 12:00:00 AM	ADDRESS	33.94442	-118.38252	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57103	16041-10002-38115	21425 W VANOWEN ST	91303	3	183B105   951	2138011023	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.19399	-118.59858	Changes to an approved set of plans. All changes are clouded under delta 4. Changes include adding/removing circuits, revising load calculations, relocating receptacles/lights on the floor plans, and revising title 24 controls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57104	16041-10001-37815	625 S BARRINGTON AVE unit 1-46	90049	11	132B145   276	4401012012	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			05/31/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.05687	-118.46824	"PC CHANGES TO APPROVED SET. CHANGES MARKED UNDER DELTA ""B"". SCOPE INCLUDES INSTALLATION OF NEW ELEVATORINCLUDING 2 NEW CIRCUITS. *************************************************  NOTE: FIRE ALARM VARIANCE HAS NOT BEEN FILED  *************************************************"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57105	16041-20003-26899	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM			PC Approved	01/29/2018 12:00:00 AM	ADDRESS	34.32381	-118.49103	1/29/2018changes to an approved set of plans.  changes are noted delta 3.  changes include removal of light fixtures and revised energy calculations.  this id plan check only.  (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,341 sq. ft.Note: Building application has been generated under 16014-20000-03627)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57106	19041-20000-50753	3341 N CAHUENGA BLVD WEST	90068	4	159B181   512	2425026009	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	04/15/2021 12:00:00 AM		Permit Finaled	04/30/2024 12:00:00 AM	ADDRESS	34.13086	-118.35124	800A 240/120V 3ph-4w service, distribution, power, and lighting for commercial office TI.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57107	19041-20000-07538	14607 W DEL PLAYA ST	91402	6	201B149   361	2650019024	(Q)RD2-1, (Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.24795	-118.45059	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57108	18041-20000-17371	7750 N GEYSER AVE	91335	3	189B121   581	2103018024	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.21178	-118.54236	Plan check for PV roof mounted system, system size: 10kW with 36 modules and 1 inverter(10kW) connected to center feed(200A bus)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57109	19041-10000-36438	3564 S MCCLINTOCK AVE	90089	9	120B197   779	5039012029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	08/20/2020 12:00:00 AM		Permit Finaled	07/09/2021 12:00:00 AM	ADDRESS	34.02211	-118.28883	Full plan check for power and energy. Scope includes adding a new 300KVA  Medium voltage transformer, (1) 600-amp panel and other associated equipment with a total lighting area of 8148-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57110	13041-10000-11619	201 N LARCHMONT BLVD	90004	4	138B189   682	5515018013	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.07478	-118.32383	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. INTERIOR TENANT IMPROVEMETN OF EXISTING SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57111	11041-20000-03327	13606-13616 W VICTORY BLVD	91401	2	180B157   959	2330012022	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	05/02/2011 12:00:00 AM	ADDRESS	34.1865	-118.42958	Plan check T24 Energy for outdoor lighting. Permit for (2) exterior lighting ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57112	14041-10000-32396	9027 N CANOGA AVE STE #M	91304	3	195B105    39	2779018036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.23429	-118.59779	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH  NEW LED FIXTURES. TOTAL AREA 1048SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57113	17041-20001-40113	10962 W LE CONTE AVE	90024	5	135B149   560	4363017002	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.06346	-118.44754	02/13/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes have been made to the lighting and power floor plans. All lighting changes have been reflected onto the Title 24 compliance forms.*****Original Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LEVEL 1  of an  (e) 2 story office building. 2790 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57114	13041-10000-08920	11900 W OLYMPIC BLVD #101	90064	11	123B149   541	4259024003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	34.03252	-118.45186	PC FOR ENERGY. ti to OFFICE.  part of hirise with GENERATOR 1750 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57115	14041-20000-20238	20140 W DELITA DR	91364	3	171B113   241	2166010020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.16494	-118.57323	PV1.  Install 8.16 kW roof-mounted, utility-interactive PV system.  Transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57116	11041-10000-09186	6801 W HOLLYWOOD BLVD 2 & 3 FLR	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	07/05/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	EXISTING MALL BATHROOMS REMODEL ON THE SECOND AND THIRD FLOOR.  WOMEN'S BATHROOM ON THE SECOND FLOORV IS TAKING OVER EXISTING MEN'S BATHROOM AND NEW MEN'S BATHROOM IS BEING BUILT ON THE SECOND FLOOR.  ON THE THIRD FLOOR IT IS JUST A BASIC REMODEL OF THE LIGHTING FIXTURES FOR BOTH MEN AND WOMEN'S BATHROOM.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57117	19041-20000-14409	10532 W BURBANK BLVD	91601	2	174B177   587	2417001046	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.17201	-118.36066	T24 PLAN CHECK ONLY FOR LIGHTS AND OUTLETS FOR A LOW RISE OFFICE BUILDING. TOTAL SQUARE FOOTAGE = 5680 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57118	10041-20000-11817	2121 S AVENUE OF THE STARS 14th Floor	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	07/29/2010 12:00:00 AM	ADDRESS	34.05554	-118.41342	Plan check T-24 Energy general/emergency lighting for office spaces on te 14th floor. Lighting on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57119	16041-20002-16355	14708 W VENTURA BLVD 2nd Floor	91403	4	166-5A149  67	2276002020	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Info Complete	02/16/2017 12:00:00 AM	ADDRESS	34.15154	-118.45347	2/16/2017(((changes to an approved set of plans.  changes noted delta 3 on plans.  relocating light fixtures verify em lighting and adding new circuits.)))[[[[2/8/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES. PROVIDING OCCUPANCY SENSORS IN ALL AREAS TO MEET SHUTOFF REQUIREMENTS]]]]Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement/change of use from office to hair salon. Total lighting area = 6,950 sq. ft.Note: Building application has been created under 16016-30000-10197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57120	15041-10000-08516	1940 CENTURY PARK EAST	90067										Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM			Corrections Issued	03/24/2015 12:00:00 AM				Energy plan check for the lobby and corridor of a commercial building. total area is 901-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57121	11041-20000-19301	4701 W JEFFERSON BLVD	90016	10	120B181   718	5057024022	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM	09/14/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.02568	-118.34737	"PLAN CHECK T24 ENERGY FOR WAREHOUSE TI. PERMIT FOR NEW CKTS. ""COMPLY WITH DEPARTMENT ORDER effective date 07/06/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57122	13041-10000-20685	15760 W VENTURA BLVD	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Issued	09/06/2013 12:00:00 AM	ADDRESS	34.1552	-118.47684	TI IN AN OFFICE BUILDING, 17TH.  TITLE 24 ONLY, REARRANGING OFFICE SPACE WITH REPLACINGSOME FIXTURES. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57123	19041-10000-33491	425 S PALOS VERDES ST	90731	15	018B201   824	7455019916	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			PC Info Complete	01/17/2020 12:00:00 AM	ADDRESS	33.74102	-118.28156	Power pc only for LA Harbor Dept admin building. Project includes replacing existing HVAC units with new ones. Scope is greater than 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57124	10041-20001-15655	6061 N TOPANGA CANYON BLVD	91367	3	177B101   111	2146025005	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.18066	-118.60615	Revision to approved plan  and existing permit # 10041 20000-13590. Change was to show power plan as installed per inspector request. Plan check T-24 Energy (general/emergency) lighting for existing Chevron  gas station. Supplimenting also 10041 20000 15655 for adding  page E-1 to complete plan as built running a conduit for low voltage camera and for sensor at the pump.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57125	16041-20000-23226	2250 E ALCAZAR ST 134B	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.06307	-118.2	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NE LIGHITNG NEW CONTROLS TO EXISTING PANELS.  TOTAL SQUARE FOOTAGE 960. SCOPE IN ROOM 134B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57126	17041-20000-18267	9355 N RESEDA BLVD	91324	12	198B125   167	2763004001	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.24065	-118.53629	PLANCHECK FOR T24 ENERGY OUTDOOR LIGHTING. DUNKIN DONUTS  9367 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57127	17041-10001-38268	1234 S DANIELS DR	90035	5	132A165   217	4330018005	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM			Reviewed by Supervisor	10/31/2017 12:00:00 AM	ADDRESS	34.05535	-118.40122	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH TESLA POWERWALL BATTERY.  TOTAL PV SYSTEM SIZE IS 5.2KWac WITH 5.8KVA STORAGE BATTERY.(10)MODULES-SOLARCITY STANDARD SC325(1)INVERTER-SOLIVIA 5.2 TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57128	14041-20000-27553	10330 N ALDEA AVE	91344	12	204B133   124	2695017006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.25859	-118.50867	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 8.8kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(41) SolarEdge P300 power optimizers(41) Kyocera KD255GX-LFB3 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57129	16041-10000-04700	704 N VERMONT AVE	90029	13	141B197   412	5539021023	C4-1VL	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	34.08405	-118.29152	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT (TAKE-OUT) COFFEE SHOP AT EXISTING SHOPPING CENTER. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND THREE NEW PANELS. TOTAL AFFECTED AREA IS 839 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57130	17041-20000-07813	201 N FIGUEROA ST 8th Floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for energy only. TI to corridor and elevator lobby on 8th floor of existing high rise office building. New lighting (incl. emergency). 1,299sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57131	15041-20000-27339	3651 S TROUSDALE PKWY CL 130	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.01922	-118.28617	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LAB IN USC. COMPUTER LAB 130.  1273 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57132	17041-10000-36232	944 E PICO BLVD # 2	90021	14	123A211   265	5132018034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.03051	-118.24925	INTERIOR ALATERATION- REPLACE HID WITH LED LUMINAIRESTITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57133	17041-10000-41863	15350 W SHERMAN WAY	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.20099	-118.46808	PLAN CHECK FOR - ADDITION TO EXISTING DISTRIBUTION BOARD. SCOPE INCLUDES NEW 1600A SECTION. WITH 1 PANEL AND 2 NEW CHILLERS, AND POWER(T-24)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57134	13041-10000-03525	20842 W TIARA ST	91367	3	174B109   108	2149013062	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.17626	-118.58588	PHOTOVOLTAIC SYSTEM FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE OF 7.2 KW. USING 30 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57135	19041-20000-33123	3450 N FLOYD TER	90068	4	159B181    82	5579005018	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Apartment			08/22/2019 12:00:00 AM			Reviewed by Supervisor	10/17/2019 12:00:00 AM	ADDRESS	34.13476	-118.3431	POWER AND ENERGY CHECK FOR NEW 5-STORY 18 UNIT APARTMENT BUILDING. NEW 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57136	13041-10000-33105	8144 N WILLIS AVE	91402	6	192B149   574	2210014018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.21917	-118.45516	PV1. ROOF MOUNTED SOLAR SYSTEM. 1 STORY. SYSTEM SIZE: 3.25 KW DC. TRANSFORMERLESS UNGROUNDED SYSTEM.(13) TRINA SOLAR TSM250P(13) SOLAR EDGE POWER OPT 250(1) SOLAR EDGE SE3000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57137	17041-10000-04128	16200 W VENTURA BLVD	91436	5	168B137   450	2284003020	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM			Corrections Issued	02/08/2017 12:00:00 AM	ADDRESS	34.15647	-118.48571	T-24, PC FOR ENERGY ONLY. INTERIOR TI REMODEL AT 2ND, 3RD, and  4TH FLOOR OF AN EXISTING COMMERICAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2472 SQ. FT. B#16016-10000-23812	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57138	16041-10000-30234	6435 N CANOGA AVE	91367	3	180B105    57	2146005186	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.18733	-118.59771	PC for energy only to an existing restaurant. Tenant improvement, adding new lighting and power. Total sqft = 2800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57139	16041-10000-16307	1888 S CENTURY PARK EAST 11TH FLR	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.06104	-118.41402	TI TO (E) COMMERCIAL BUILD., SCOPE ON THE CORRIDOR AND RESTROOM. INSTALL NEW LIGHT FIXTURES. PC FOR T-24 ONLY. TOTAL AREA: 2,169 SQ. FTB# 16016-10000-05919	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57140	19041-20000-36005	4234 S GRAND VIEW BLVD	90066	11	111B157  1114	4232015020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	33.99681	-118.42486	Plan check for PV roof mounted system, PV system size: 3.96kW DC, 3.591KW AC with 12 PV Modules and 6 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57141	11041-10000-04563	3801 S GRAND AVE	90037	9	117A203   118	5122026011	[Q]CM-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	03/24/2011 12:00:00 AM	ADDRESS	34.015	-118.27962	REMODELING OF OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57142	19041-20000-19481	1457 N VAN NESS AVE 2nd &3rd-FLR	90028	13	147A191   102	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM			PC Info Complete	05/22/2019 12:00:00 AM	ADDRESS	34.09731	-118.31598	Plan check for Title 24 only in existing space T.I. Partial 2nd and 3rd circuits existing to remain. Total area: 2350 sq ft. B#18016-10000-39976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57143	10041-20000-10653	4051 S LEIMERT BLVD	90008	10	114B189   344	5023003025	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM			PC Approved	06/07/2010 12:00:00 AM	ADDRESS	34.01067	-118.32351	REVISION TO APPROVED PLAN # 09041-20000-07505. CHANGE IS FEEDING PANEL C FROM PANEL B AND REMOVING PANEL PHP-2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57144	17041-20000-43170	3915 W 7TH ST	90005	10	132B193   262	5092029045	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Apartment			11/30/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05982	-118.31184	pv2install roof mounted pv system sized 16.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57145	13041-10000-34509	7118 N BURNET AVE	91405	6	183B145   135	2220004180	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			Verifications in Progress	03/06/2014 12:00:00 AM	ADDRESS	34.19992	-118.46212	PV1, Install a 4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57146	17041-20000-19457	1825 N WESTERN AVE	90027	13	150A193   262	5544004015	C4-1D	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Closed	07/11/2017 12:00:00 AM	ADDRESS	34.10411	-118.30957	Plan check for a fire alarm system for a 2-story apartment building. System consists of (1) FACP, (1) annunciator, and (19) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57147	18041-10000-43920	5870 W JEFFERSON BLVD UNIT F	90016	10	120B173   383	4205027010	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.02285	-118.37583	Energy plan check for an office T.I located in the first floor of a commerical building. Scope includes new lighting and equipment with a total area of 6857-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57148	15041-10000-29693	2030 E 7TH ST	90021	14	124-5A217 264	5166015018	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.03439	-118.23113	FULL PC FOR POWER AND ENERGY TO A (N) 4 LEVEL,  W/  ROOF, PARKING STRUCTURE. NEW 600AMP DISTRIBUTION BOARD BEING FED FROM EXISTING DISTRIBUTION BOARD. TOTAL SQ. FT. 153,000, VERIFY ENGINEER'S LICENSE NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57149	13041-20000-06777	22344 W LULL ST	91303	3	186B101   132	2012020048	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	PIN	34.20853989	-118.61399448	Photovoltaic system on roof of single family dwelling. 200A service upgrade has been included in permit fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57150	18041-20001-42034	787 S ALAMEDA ST UNIT #100	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM			PC Approved	12/03/2018 12:00:00 AM	ADDRESS	34.03365	-118.24048	PC FOR T24 ENERGY ONLY FOR A SALON. SCOPE INCLUDES LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 875 SQ.FT THIS IS PLANCHECK ONLY! PERMIT PAID UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57151	16041-20000-22725	5750 W WILSHIRE BLVD	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MAIN LOBBY AREA. 2522 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57152	15041-10000-32605	11726 W BARRINGTON CT	90049	11	135B145   652	4401007018	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.06407	-118.46956	T-24, PC FOR ENERGY ONLY, TO AN (E) RETAIL SPACE. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND 2 NEW PANELS. TOTAL SQ. FT. 746.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57153	13041-10000-35709	807 E 12TH ST #148	90021	14	123A211    42	5132009013	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.03247	-118.25043	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 168 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57154	15041-10000-41316	7100 N HAYVENHURST AVE	91406	6	183B137   146	2224017022	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Expired	11/17/2017 12:00:00 AM	ADDRESS	34.19917	-118.49222	$0 FEE PER SENATE BILL 12222.<<PV2, ROOF MOUNTED SYSTEM TO A COMMERCIAL BUIDLING. 320 MODULES AND 3 INVERTERS, TOTAL SIZE 84KW-AC. (320) SOLAR WORLD 320 XL MONO(3) SOLECTRIA-PV1 28TL>>	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57155	19041-20000-28606	9456 N CREEMORE DR	91042	7	198B205   274	2572029017	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.24007	-118.27147	pv1install rof mounted pv system sized 7.5KW AC interconnected with msp.standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57156	18041-10000-31627	11668 W DARLINGTON AVE	90049	11	129B145    96	4265005019	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			08/20/2018 12:00:00 AM	02/10/2023 12:00:00 AM		Permit Finaled	05/30/2024 12:00:00 AM	ADDRESS	34.05304	-118.46343	PC FOR POWER AND ENERGY FOR 5 STORY 17 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW 1000A 120/240V 3 PHASE 4 WIRE SERVICE, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 16943 SQ. FT. B#18010-10000-02991	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57157	15041-20002-01212	10342 N LINDLEY AVE	91325	12	204B125   120	2731010016	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			03/27/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	PIN	34.25819985	-118.52695571	[[[[3/27/15 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. CHANGES ARE CLOUDED. RELOCATION OF SUB PANEL]]]]PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20.0KW INTERCONNECTED WITH MSP.THIS IS 1  PV DESIGN OF TWO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57158	13041-10000-01025	6109 N KENTLAND AVE	91367	3	177B097   368	2039029010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2013 12:00:00 AM	02/04/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.18174	-118.61789	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 9.6 KW ON A SOLAR PV STANDARD ELECTRICAL PLAN. USING 40 MODULES IN 4 STRINGS.  [INVERTER: FRONIUS # IG PLUS 10.0-1 |||| MODULES: TSM-240 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57159	10041-30000-07428	7060 W HOLLYWOOD BLVD 5th FL	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM			PC Approved	03/18/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	Plan check T-24 Energy for a TI  on 5th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57160	19041-10000-31202	9106 S WESTERN AVE	90047	8	094-5A193  75	6037028037	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	33.95423	-118.3088	pc for FA for after school building. 1-FACP and 31-device	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57161	14041-20000-15155	20050 W VINTAGE ST	91311	12	204B113   708	2726003058	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.25165	-118.57066	PV1.  Install 9 kW rooftop-mounted, utility-interactive PV system.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57162	12041-10003-27063	8500 W BURTON WAY SUITE 200	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	(((Revision to original Title 24 Part 6 plan check.  3 new LED wall sconce fixtures added.))) TI TO RESTAURANT PART OF THE crusoe project approved per mehdi . not a high rise . 1799 SFDELTA 4 CHANGES TO THE APPROVED PLANS.     CONDITION WAIVED PER BEHZAD BY MEHDI 10/22/2012 (((((((((((((( cHANGES MADE TO PREVIOUSLY APPROVED SET, ADDITION OF 15HP  FIRE PUMP AND 3/4 HP JUCKY PUMP, CONVERSION OF TWO UNITS TO ONE PENT HOUSE, RELOCATING PANEL, LOAD CALS )))))))))))))))))(((((((((((( Revision to previously approved set , change of out door and indoor lits and title 24, new added ckts, relocation and reckting..  8-9-12  ))))))))))))))))))))))))New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57163	14041-20000-20262	6910 N NEWCASTLE AVE	91335	3	183B129   770	2122008008	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.19598	-118.52515	Standard plan: 5KW PV1 roof-mounted system with one Solaredge SE5000A transformerless inverter, (22) Trina Solar TSM-255p modules and Solaredge P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57164	17041-20000-28910	10964 W VENTURA BLVD	91604	2	162B173   572	2378007012	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.14	-118.3695	Plan check for energy only. TI - change of use from retail to restaurant. New lighting (incl. emergency) - 1,088sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57165	19041-10000-20912	10560 W DRAPER AVE	90064	5	126B161   534	4318016033	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.03849	-118.41602	[E-plan] PV1 11.4 kW AC rooftop solar system on (E) SFD.  Install (2) Inverters: 7.6 kW and 3.8 kW,  (35) Modules, (1) New 125A Load Center**Note: Derating MCB to 175A shall ne under express permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57166	19041-10000-32279	9717 W PICO BLVD	90035	5	132A165   258	4330018024	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.05485	-118.40008	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57167	16041-10000-42005	2118 S BROADWAY	90007	9	121-5A205  26	5126032002	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Issued	11/30/2016 12:00:00 AM	ADDRESS	34.02882	-118.26722	PC FOR T24 ENERGY ONLY. REPLACEMENT OF LUMINAIRES TO MORE ENERGY EFFICIENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57168	12041-10000-30852	10435 N SCOVILLE AVE	91040	7	204B189   111	2560008001	R3-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Apartment			12/24/2012 12:00:00 AM			Reviewed by Supervisor	11/19/2013 12:00:00 AM	ADDRESS	34.25887	-118.3141	new 40 unit apartment complex 4 floors with 2 level of sub-terrainial parking 5 typical units. fire alarm plans NOT included. Four separate buildings but one plan for all buildings. Each building has 10 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57169	17041-20000-31231	244 N LADERA DR	90210	5	141B157    71	4358006042	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.08252	-118.42398	New single family dwelling with 1200A 208Y/120V 3ph-4w service.  175 kW backup generator.Building permit under 16010-20000-05465.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57170	13041-20001-36028	15111 W NORDHOFF ST PV1	91343	7	198B145   375	2656022007	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.23565	-118.46139	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 6.0KWAC. PERMIT HAS ALREADY BEEN PULLED AND ZONING HAS BEEN CLEARED ON APPLICATION#: 13041-20000-35714	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57171	16041-30001-35498	14570 W EL CASCO ST	91342	7	225B149   114	2504003003	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.31604	-118.44984	Expedite fees only.            Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 9.5 kWac.  Microinverter system with 3 branch circuits and a new 100 amp AC load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57172	17041-20000-22044	1517-1521 W 8TH ST	90017	1	130-5A205 145	5142023003	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			06/29/2017 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.05203	-118.27103	new 34 unit apartment building 1200 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57173	18041-10000-28379	6300 W WILSHIRE BLVD	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.06319	-118.36591	PLAN CHECK FOR TITLE RESTAURANT TI FOR T- 24  ENERGY ONLY. FOR A TAKEAWAY COFFEE SHOP ON THE FIRST FLOOR IN A HIGH RISE BUILDING. TOTAL AFFECTED AREA 843 SQ. FT.SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS.B# 18016-10000-22961	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57174	11041-20000-23490	10430 W WILSHIRE BLVD 1-124	90024	5	135B157   223	4326036***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Public Safety Only			11/03/2011 12:00:00 AM	02/17/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.06564	-118.43046	new Fire/ Life safety system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57175	15041-20001-23142	325 S CROCKER ST	90013	14	129A213   385	5147004018	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.0458	-118.24093	Title 24 plan check only.  Total area = 750 sq. ft.  T.I. to existing office space.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57176	13041-20001-13862	4266 S LINCOLN BLVD SUITE K	90292	11	105B153    73	4230001018	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	33.98605	-118.4435	(((SUPPLEMENTAL APPLICATION FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED. PC FOR T24 ENERGY ONLY. )))) ORIGINAL APPLICATION # 13041-10000-13862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57177	15041-10001-22097	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Changes to approved set of plans . Note, changes under delta 14 only. Scope of work includes the addition of the lab panels and space. Total sq. ft. 29459. The permit fee is paid for application 15041-10001-14660	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57178	15041-10001-32526	1950 E 103RD ST	90002	15	091-5A215 138	6066005001	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	33.94298	-118.23783	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE REVISION TO TYPE OF FIXTURE FOR INDOOR. REVISION TO SITE LIGHTING. ALL CHANGES CLOUDED DELTA 1 REVISIONS IN BLUE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57179	13041-10000-24603	750 N HILL ST UNIT P	90012	1	135A215   384	5408020003	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	34.06203	-118.2397	Tenant improvement of retail space in (E) 2-story shopping center.  T24 plan check only per inspector's request (under express permit 13041-10000-22464).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57180	17041-10000-46167	4610 N EAGLE ROCK BLVD	90041	14	157-5A221  34	5474003004	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.12767	-118.21745	PC FOR CHANGE OF USE PORTION OF THE BUILDING FROM RETAIL TO  SMALL RESTAURANT FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1264 SQ.FT B# 17016-10000-25031	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57181	15041-20000-02260	5706 W SANTA MONICA BLVD	90038	13	144B189   691	5536017034	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	34.0906	-118.31392	Plan check for energy only. First time tenant (7/11). New lighting including emergency. Total sqft. 2,260.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57182	19041-10000-02260	1431 NAGOYA WAY	90731	15	012B201    16	7440031904	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	06/17/2020 12:00:00 AM		Permit Finaled	11/16/2021 12:00:00 AM	PIN	33.73191747	-118.27658596	INSTALL 93 LIGHTS & SECURITY EQUIPMENT. T-24 ENERGY. 78,495 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57183	19041-10000-12242	4551 S GLENCOE AVE	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC FOR T24  ENERGY ONLY FOR OUTDOOR LIGHTING WORK.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES TOTAL AFFECTED AREA 1386 B#19010-10000-00953	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57184	15041-10000-20822	777 W COLORADO BLVD	90041	14	163-5A231 101	5709002018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.14074	-118.1832	ADDITION TO EXISTING CHURCH BUILDING; THIS ADDITION WILL SERVE AS PARKING ON FIRST FLOOR WITH ACCESS TO ROOF.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57185	16041-10000-25536	101 S BRIDEWELL ST	90042	14	153A233   288	5492038025	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.03	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.11282	-118.17794	PV 2 solar system installation roof mounted to apartment complex. System is connected to house main switchboard. (477) Solar modules, Installing (9) central inverters rated at 15.0 kw each for a total system size of 135 kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57186	13041-10000-02654	4950 N LEDGE AVE	91601	4	168B177    38	2420009021	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.16092	-118.35702	PHOTOVOLTAIC SYSTEM FOR SINGLE STORY SINGLE FAMILY DWELLING. PV1 SYSTEM TOTAL SIZE OF 3.67KW. TOTAL OF 17 UNITS. MICROINVERTER ENPHASE M215-60-2LL-S22. PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57187	17041-10000-37567	444 S FLOWER ST 33rd Floor-Rest Room	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only in existing sapce restroom 33th Floor. Total area: 625 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57188	16041-20000-44236	10240 N SEPULVEDA BLVD	91345	7	204B145   388	2660016028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.25651	-118.4671	remove existing hid fixtures and replace with new led.  plan check for energy outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57189	13041-20000-11843	1625 W VERNON AVE	90062	8	111B193    95	5021023014	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.00383	-118.30756	PV1 SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 12.24 KW. USING 48 MODULES, 2 TRANSFORMED INVERTERS. NONSTANDARD PLAN. ROOF MOUNTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57190	16041-20004-44615	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED DELTA 19 CHANGES ONLY. CHANGES MADE TO LIGHTING FIXTURE SCHEDULE, T24 SHEET VALUES, CHANGES MADE TO ALL LIGHTING FLOOR PLANS WITH ADDITIONS OF LIGHTS TO STAIRWELL. LASTLY, REMOVAL OF ALL PERMANENT LIGHTS AND EQUIPMENT AND INSTALLING TEMPORARY LIGHTS INSTEAD FOR THE BASEMENT FLEXIBLE EVENT SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57191	16041-20001-06286	16541 W LASSEN ST	91343	12	201B137   139	2678026001	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Apartment			02/23/2016 12:00:00 AM			PC Approved	04/01/2016 12:00:00 AM	ADDRESS	34.25035	-118.49255	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a residential building part of a shared parcel/service (3 units w/3 meters). Interconnect with a 125A MSP. System size: 4.2kW. (21) 265W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57192	16041-20000-45343	8590 W PICO BLVD	90035	5	129B173    75	4303035074	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			12/27/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.05344	-118.37821	Fire alarm plan check only. New fire alarm system for a 36-unit, 7 story apartment building over 1-level subterranean parking. FACP w/ 150 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57193	12041-20000-29992	4824 N TUJUNGA AVE 1-31	91601	2	168B173   368	2353023007	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.15833	-118.37877	Plan check for new 31 unit apartment building. Full plan check. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57194	14041-20001-15930	3691 N FREDONIA DR	90068	4	159B177   295	2425006003	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM			PC Approved	07/11/2014 12:00:00 AM	ADDRESS	34.13297	-118.36147	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 3 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57195	15041-10000-28784	5904 W SUNSET BLVD	90028	13	147A191    82	5545015001	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Info Complete	09/01/2015 12:00:00 AM	ADDRESS	34.09788	-118.31824	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-70000-26646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57196	16041-10000-43673	16913 W GAULT ST	91406	6	183B133   294	2227028016	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.19949	-118.50184	Plan check for PV roof mounted system. System size: 4.7kW with 17 modules  and 17 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57197	16041-10000-33179	1501 E 41ST ST	90011	9	115-5A211 171	5117013900	OS-1XL	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Issued	09/19/2016 12:00:00 AM	ADDRESS	34.00873	-118.24735	Plan check for T24 only. Remove indoor+outdoor HID fixtures and replace with new LED fixtures. Total area: 27,625 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57198	17041-10000-38042	1601 N VINE ST 2ND-4TH	90028	13	148-5A187 367	5546009***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.09996	-118.32693	Full PC for First time tenant on 2nd, 3rd and  4th floors of an 8-stories office / retail building. # 14010-10000-01878	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57199	11041-10002-18110	11659 W SANTA MONICA BLVD	90025	11	126B149   212	4262002015	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.04421	-118.45548	Modification to previously approved set of plans for Rev (3) only.  Relocated dist. xfrmr to elec room, new dist. board to feed xfrmer with subpanels and also feed panel A.         <<<<change of switch gear from outdoor to indoor>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57200	15041-10000-17830	4256 N CALEDONIA WAY	90065	14	159A215   184	5678020015	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	34.12824	-118.23426	INSTALL NEW 2.86 KW DC  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (11) MODULES: KYOCERA KU2606XPA(1) INVERTER: PVI-3000-OUTD-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57201	14041-20000-02256	16007 W LASSEN ST	91343	12	201B141   157	2669024007	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.25026	-118.4808	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57202	16041-10000-35681	11468 N MEADOWVIEW LANE UNIT 158	91331	7	213B165   548	2532011***	(Q)RD2-1-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM			PC Info Complete	10/07/2016 12:00:00 AM	ADDRESS	34.27865	-118.40064	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(12)MODULES-CANADIAN SOLAR CS6-320P(1)INVERTER-GROWATT-5000MTL-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57203	14041-20000-32556	6624 N NESTLE AVE	91335	3	180B125   364	2125019007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.19108	-118.53066	PV1Install a roof-mounted solar array on a SFD. Interconnec with a 200A MSP.System size: 4.3kW. Ungrounded system.20 EnPhase M215-IG microinverters with 20 250W pv modules across two strings (12+8).Note: the solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57204	15041-20000-39349	7737 N ARCOLA AVE	91352	2	189B177   763	2405007001	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.21143	-118.3532	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11 kW AC.(50) SW 250 Poly(1) PRIMO 6.0-1(1) PRIMO 5.0-1Permit Fee's zero dollar ($0) per California State Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57205	14041-10000-07764	155 W WASHINGTON BLVD	90015	14	123A207    74	5126028010	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM			PC Approved	04/09/2014 12:00:00 AM	ADDRESS	34.03191	-118.26615	permit to be pulled at EPC counter only. PC for energy only. TI TO (E) RESTAURANT on the 1st floor in a high rise (03016 20000 06323?) [MODE-O-DAY BUILDING COMPANY retrofit=yes]. 100A service existing,  emergency lighting installed (Inspector to verify if generator is present). Less than 400A, relocating meter and panel within the storage room, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57206	13041-10000-20574	800 S HOPE ST 5th floor	90017	14	129A209   202	5144020900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.0463	-118.25904	PC FOR ENERGY ONLY. permit to be pulled at EPC counter only. Hirise. *** NEEDS THE DUAL INPUT EXIT SIGNS ***T.I AND CHANGE OF USE TO AN EXISTING OFFICE BUILDING ON LEVEL 5 PROPOSED TO INSTALL NON-STRUCTURAL PARTITIONS TO CREATE SPACE FOR A TRADE SCHOOL F.D.I.M. (TOTAL S.F = 14430)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57207	12041-20001-28878	2131 S BEVERLY GLEN BLVD	90025	5	129B157   395	4317012062	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			11/27/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.05151	-118.42183	TWO STORY 6 UNIT APT OVER SUBTERRANIAN GARAGEchange service from overhead to underground	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57208	15041-10001-10973	2710 E MEDIA CENTER DR	90039	1	150B213  3658	5442032006	[Q]M2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	PIN	34.10636393	-118.24150489	03/14/16Changes to an approved set of plans. Changes include adding/removing/relocating receptacles, and lighting fixtures for the first floor conference rooms. Also, adding a 100A panel.  (((((TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 25761.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57209	19041-10000-34997	5453 W HOLLYWOOD BLVD A-D	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	12/15/2021 12:00:00 AM		Permit Finaled	09/27/2023 12:00:00 AM	ADDRESS	34.10193	-118.30871	FULL PC  FOR NEW NORM'S RESTURANT IN EXISTING TENANT SPACE. TOTAL NEW LOAD IS MORE THAN 400A. AREA OF SCOPE 5,836SFBUILDING PERMIT: 19016-10000-27907	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57210	13041-10005-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Approved	09/03/2014 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delt 10 revisions to permitted set of plans : HID luminaires replaced with LED luminaires ; Title 24 compliance forms were revised to incorporate the changes; Replacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57211	10041-20000-12717	8013 W MELROSE AVE	90046	5	141B177   550	5527014003	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM	07/02/2010 12:00:00 AM		Permit Finaled	07/26/2010 12:00:00 AM	ADDRESS	34.08391	-118.36425	Plan check T-24 Energy (general/emergency) lighting for retail (Salsa) TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57212	19041-30000-04234	601 S FIGUEROA ST 43rd Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is the 43rd floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 16,390 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57213	14041-20001-06927	1100 W WILSHIRE BLVD suite B	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.05228	-118.26384	change feeder tap to 2 oddadd two pumps on generator.COMPLY WITH DEPARTMENT ORDER DEFFECTIVE DATE 12/13/2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57214	11041-20000-06146	10940 W WILSHIRE BLVD #1250	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	03/29/2011 12:00:00 AM		Permit Finaled	04/28/2011 12:00:00 AM	ADDRESS	34.05822	-118.4452	T.I. to existing high rise building.  Install general/emergency lighting on 12th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57215	12041-10000-04924	19310 S PACIFIC GATEWAY DR	90502	15	057B197     9	7351031030	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	33.85616	-118.29473	New warehouse/distrbution building with office space on 2 floors.  Plan check for Power and Energy.  (((Applicant has a pre-printed check, additional fees will need to be collected.  424,349 sq ft for Energy, etc))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57216	14041-10000-16628	6255 W SUNSET BLVD 17thFloor	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Issued	06/20/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Permit to be pulled at EPC counter only. Plan check for energy only. TI to restroom 17th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57217	16041-10000-39010	1430 W MIRAMAR ST	90026	13	133-5A207 232	5153028022	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Apartment			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.05965	-118.2619	PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. SCOPE INCLUDES 57 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57218	13041-10001-09206	19270 W DEARBORN ST	91324	12	198B117   184	2762017037	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM			PC Approved	08/14/2013 12:00:00 AM	ADDRESS	34.23725	-118.55241	Change of module from REC 250 PE to ET Solar ET-P660250WB.  (((PV1 SINGLE FAMILY DWELLING 1 STORY HOUSE. 5.184 kW SOLAR INSTALLATION. ENPHASE MICROINVERTER M215. TOTAL MODULES 24: REC 250 PE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57219	19041-20002-07146	411 S VIRGIL AVE	90020	13	135B197   628	5077002034	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			06/12/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.06621	-118.28724	6/12/2019CHANGES TO AN APPROVED SET OF PLANS.  CHANGES TO RELOCATE MODULES AND EQUIPMENT.  THIS IS PLAN CHECK ONLY.  ((((PV2.  Install 22.27 kW DC / 20.45 kW AC-CEC roof mounted grid tied PV system.  (61) modules with (2) 10 kW rated string inverters.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57220	18041-20000-03607	10925 W BLUFFSIDE DR	91604	2	162B173   304	2366021008	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			01/31/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.14115	-118.36774	Plan check for a fire alarm system for an existing 4-story apartment building. Scope of work is the replacement of the existing FACP and the addition of devices. New FACP will interact with existing devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57221	13041-20000-35738	14006 W RIVERSIDE DR MACY's	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	Change to lighting and loads in an existing department store.  Full plan check is requested by the applicant for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57222	19041-20001-06839	9333 S LINCOLN BLVD	90045	11	096B161   838	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	33.95576	-118.41559	Expedited plan check fee.PV2.  Install 120.96 kW DC / 108.54 kW AC roof mounted grid tied PV system.  (336) modules with (4) 30 kW rated string inverters.  System 3 of 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57223	12041-10000-28707	5510 S LINCOLN BLVD 2ND FLOOR	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	33.97299	-118.43051	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57224	18041-30000-38374	11444 W OLYMPIC BLVD 8TH FLR	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.03654	-118.44363	Plan check for Title 24 Energy only in existing high-rise building T.I. office area. Total area: 19,335 sq ft. B#18016-10000-19001	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57225	12041-10000-06845	5216 S FIGUEROA ST	90037	9	108B201   172	5001033033	C2-1VL	South Los Angeles	Southeast Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Apartment			03/27/2012 12:00:00 AM	03/13/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	33.99536	-118.28247	new 2-stories apartment building having 19 units -600A SERVICE; 8 CIRCUITS  PER UNIT; VARIANCE IS FILED TO SEPARATE THE FA PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57226	19041-10000-49142	11458 W BURBANK BLVD	91601	2	174B169   844	2350004038	C4-1, R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Apartment			11/27/2019 12:00:00 AM			PC Info Complete	03/18/2020 12:00:00 AM	ADDRESS	34.17199	-118.38088	PLAN CHECK FOR POWER ONLY. SCOPE OF WORK INCLUDES REPLACEMENT OF UNIT PANELS, NEW HOUSE PANEL, AND NEW 600 AMP SECTION. SERVICE SIZE IS AN EXISTING 600 AMPS, 120/240 VOLTS, 1�, 3W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57227	14041-10000-11933	1409 E 48TH PL	90011	9	111A211    91	5107022025	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.20	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM			Corrections Issued	05/05/2014 12:00:00 AM	ADDRESS	33.99945	-118.24959	2.55 KW, ROOF MOUNTER ONE STRINGS, LOAD CENTER, MAN DE RATED. ONE STORY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57228	13041-10000-03233	316 N JUANITA AVE	90004	13	138B197   221	5501001800	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.07694	-118.29037	LIGHTING FOR OUTDOOR CANOPY. TOTAL AREA 890 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57229	14041-10000-33067	4812 S AVALON BLVD 1-7	90011	9	111A207   106	5108009029	[Q]R4-1	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Apartment			11/26/2014 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	09/07/2015 12:00:00 AM	ADDRESS	33.9993	-118.26494	Power plan check for a new 2-story 7-units apartment construction with 400 amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57230	17041-10000-18977	938 N NORDICA DR	90065	1	153A221   304	5475017028	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	Yes	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.11294	-118.2199	PC FOR BATTERY STORAGE UNIT. USING TESLA POWERWALL 2.0. SYSTEM IS 5.8KW WITH STORAGE UP TO 13KWH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57231	19041-10001-45898	170 S GLESS ST	90033	14	127-5A219  27	5172003042	RD3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM			PC Approved	02/14/2020 12:00:00 AM	ADDRESS	34.04542	-118.22293	EXPEDITE FEESPV2, NEW COMMERCIAL ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 44KWac/53KWdc. SCOPE OF WORK IS 136 MODULES (HANWHA 390), TWO CENTRAL INVERTERS (SMA STP 24000 AND SMA STP 20000), LEADING TO TWO PV SUBPANELS, AND A BATTERY BANK THAT IS RATED AT 30KW. CONNECTED TO AN EXISITING 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57232	11041-10000-18871	15900 W VALLEYVIEW CT 2ND FL	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			09/06/2011 12:00:00 AM	09/06/2011 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.30584	-118.47951	AT ST JUDE MEDICAL, OFFICES ARE REMODELED FOR THE DEMONSTRATION OF MEDICAL SIMULATOR  EQUIPMENT- NON PATIENT USEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57233	17041-20000-38318	901 E E ST	90744	15	030B209   720	7424014095	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Issued	10/24/2017 12:00:00 AM	ADDRESS	33.77631	-118.25153	Replacement of (E) luminaires with LED fixtures in freezers and freezer dock.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57234	14041-10000-35665	921 W VENICE BLVD	90015	1	126A203   113	5135030011	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			12/26/2014 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.04013	-118.27572	Plan check for power and energy. Project site is a new 3-story building (warehouse). Total lighting area = 15,187 sq. ft. New 800 amp service. Installation of a new 800 amp-rated switchboard and (4) panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57235	12041-10000-21455	716 N HIGHLAND AVE	90038	4	141B185   470	5524011026	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			PC Approved	09/11/2012 12:00:00 AM	ADDRESS	34.08412	-118.33839	TI in an existing restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57236	18041-10000-43636	5171 N OTIS AVE	91356	3	171B125   421	2161019013	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	01/12/2019 12:00:00 AM	ADDRESS	34.16516	-118.53565	*Permit fee is zero dollar per AB-1414/SB-1222*NEW ROOF MOUNTED 15 kW AC PV SYSTEM WITH 56 PV MODULES WITH OPTIMIZERS  AND (2) INVERTERS: (1) SE10000, (1) SE5000 ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57237	14041-20000-21597	6422 N WILKINSON AVE	91606	2	180B165   669	2333003021	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Expired	10/20/2016 12:00:00 AM	ADDRESS	34.18748	-118.40402	New roof mounted PV system with system size 6.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57238	11041-10000-22958	770 W WILSHIRE BLVD	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM			PC Approved	10/26/2011 12:00:00 AM	ADDRESS	34.04914	-118.25811	T.I. to an existing high-rise office building.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57239	13041-20000-30124	633 W 5TH ST 16TH FLOOR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.05099	-118.25468	T24 FOR EXISTING HIGHRISE OFFICE SPACE. RETROFITTING LIGHTING, RECONNECTING TO EXISTING CIRCUITS. SCOPE OF WORK ON THE 16TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57240	18041-20000-37800	5629 N LANKERSHIM BLVD	91601	2	174B169   740	2338027008	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.17299	-118.37974	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57241	16041-20002-02885	7900 N BALBOA BLVD BLDG 'G'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Issued	08/05/2019 12:00:00 AM	ADDRESS	34.21347	-118.50092	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 3 ONLY. CHANGES INCLUDE ADDING NEW LOADS AND SUBPANEL.<<<Plan check for power and energy Aircraft Hangar Building 'G' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' G' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57242	19041-20000-48675	9333 W KIRKSIDE ROAD	90035	5	129B169   901	4306021015	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.04854	-118.39254	INSTALL (2) NEW TESLA POWERWALL ON EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57243	10041-20000-02966	440 S VERMONT AVE	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			02/19/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	04/11/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Plan check power and energy for tenant development to new 3 story retail building and basement with levels 2 and 3 as parking. Level 1 Methane.Shell bldg. 09041-20000-22007	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57244	15041-20000-04195	582-588 S MATEO ST	90013	14	126A217   105	5164007001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.03901	-118.23266	replace existing 800 amps service	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57245	15041-10000-02289	3528 E EMERY ST	90023	14	117A225   329	5192016007	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.01402	-118.20178	Plan check for Title 24 only. Project scope is to remove existing HID light fixtures and replace with new LED fixtures. Total lighting area = 2,920 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57246	13041-20000-32151	9600 N TOPANGA CANYON BLVD	91311	12	201B101   464	2746018010	QMR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.24476	-118.60676	PC FOR T24 ENERGY ONLY. TOTAL AREA 3420 SQ FT. NEW LIGHITNG. EXISTING OFFICES. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57247	13041-10000-24781	6250 W HOLLYWOOD BLVD #600	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			Corrections Issued	09/10/2013 12:00:00 AM	ADDRESS	34.10133	-118.32547	INSTALL SMALL  LIGHT AND OCCOUPANCY SENSOR FOR RESTROOM. NO LIGHTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57248	15041-10000-01014	2635 N PASADENA AVE	90031	1	139-5A221  42	5205020022	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.07776	-118.21553	PC FOR T24 ONLY. ALTERATIONS TO EXISTING GYMNASIUM & ADMINISTRATION AREA. TOTAL AREA 5658 SQ FT.B#14016-10000-25662.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57249	12041-10000-30495	15905 W SUNSET BLVD	90272	11	129B125   402	4420001003	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.04898	-118.53375	PV2 SOLAR INSTALLATION ROOF MOUNTED ON A CHUCRCH/SCHOOL.  108 PANELS IN TWO ARRAYS. SYSTEM SIZE IS 27.5KW. USING ENPHASE M215 MICROINVERTERS AND LG 255 S1C MODULES.  SINGLE STORY BUILDING PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57250	16041-10000-17077	1147 N VINE ST	90038	13	144B185   551	5533007033	C2-1D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.09215	-118.3268	T-24, PC for energy only. Change of use from office to child care facility. TI to existing building. Installing 3 new 100A panels. Newly connectd load is less than 400 Amps. Total sq ft = 6532	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57251	16041-20001-18738	1901 W BEVERLY BLVD	90057	13	135A205    38	5157027052	C2-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	ADDRESS	34.06582	-118.26799	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 18.53 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57252	16041-20001-43656	20312 W HAMLIN ST	91306	3	180B113   401	2136022003	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.19072	-118.57598	1.26.2017 - Plan check standard plan that matches site installation per inspector request.=====Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57253	17041-10001-38547	9753 N SUNLAND BLVD	91040	7	201B177   231	2543032022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.24724	-118.35395	((*FEE EXPEDITED PER APPLICANT))INSTALL NEW ROOFTOP SOLAR SYSTEM ON A SFD, 9KW AC SYSTEM WIRH (28) AC MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57254	16041-10000-22231	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			06/23/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.03982	-118.24098	PC FOR POWER AND ENERGY. INTERIOR/EXTERIOR BUILDING RENOVATION/REPAIRS/ALTERATIONS.UPGRADES AND IMPROVEMENTS TO UNITS. UPGRADING SERVICE FROM 600A TO 800A. ADDING RESTROOMS. TOTAL AREA 9965 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57255	17041-10000-08113	20539 W VENTURA BLVD	91364	3	171B109    50	2166033033	(Q)C2-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	33.9787	-118.31759	T24 ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES 131250 SQ FT. (OUTDOOR+ INDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57256	12041-10000-09015	1311 N SAN FERNANDO ROAD BLDG B	90065	1	150B213  3619	5442002908	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.09591	-118.23223	Plan check for new 16 unit apartment bldg. 'B'Application for deferred approval of fire alarm system NOT submitted.(Taylor Yard Apartment (Building B) - construct new 16 unit low restricted affordable apartment with parking option II  - 100% PDPP.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57257	18041-20002-19250	4166 N MURIETTA AVE	91423	4	165B153   871	2266024036	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Closed	01/13/2023 12:00:00 AM	ADDRESS	34.14579	-118.43742	08/21/2018 Changes to an approved set of plans. System size is now 11.2 kWdc and consists of (2) inverters, (35) modules, and (2) load centers. Module model has changed.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (2) inverters, (34) modules, and (2) load centers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57258	11041-20000-24963	9258 W NIGHTINGALE DR	90069	5	150B169  1384	5561007023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2011 12:00:00 AM	12/09/2011 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	ADDRESS	34.10357	-118.39049	13.2 KW photovoltaic system on roof of single family residences.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57259	17041-10000-08310	8561 W HILLSIDE AVE	90069	4	148-5A173 415	5558030013	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM			PC Approved	05/09/2017 12:00:00 AM	ADDRESS	34.10006	-118.37312	PC FOR NEW SFD. 1000A SERVICE. PC ONLY. PERMIT ISSUED UNDER BUILDING COMBO. 2016 PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57260	15041-20002-07426	13215 W OTTOMAN ST	91331	6	195B157   158	2627014023	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM			PC Approved	04/06/2015 12:00:00 AM	ADDRESS	34.23396	-118.42091	Change to approved set. derated the main circuit breaker to 150A. The applicant provided the load calculation for derated the main circuit breaker*****Changes to approved set.  Inverter changed from Power One UNO-7.6-TL to ABB PVI-6000.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (27) modules and (1) inverter. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57261	11041-20000-22582	1232 N SUNSET PLAZA DR	90069	4	144B169    58	5559008020	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2011 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	34.09401	-118.38112	new single family house	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57262	18041-10000-11945	1645 N NORTH MAIN ST	90012	1	136-5A219 643	5409003036	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.06727	-118.22714	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57263	16041-10000-04914	385 E SWINFORD ST	90731	15	021B201   194	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	33.7494	-118.27878	"New Fire alarm system installation on (E) 2-story commercial build. ""Catalina Express"". (1) FA panel, (1) Comm.panel (43) devices."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57264	17041-10000-34352	3831 S HUGHES AVE #A	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Issued	10/05/2017 12:00:00 AM	ADDRESS	34.02242	-118.39823	PC for T24 only for luminaire modification in place. Total of 1755sqft. Installing new receptacles and circuits. B# 17016-10000-23505	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57265	18041-20000-22454	8216 S WESTERN AVE	90047	8	099B193  1432	6034016027	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM			PC Info Complete	12/19/2019 12:00:00 AM	ADDRESS	33.96409	-118.3088	1600A 208Y/120V 3ph-4w service, distribution, power, and lighting for new commercial building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57266	13041-10000-32955												Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM					N	N	Express Permit	06/10/2024 12:00:00 AM
57267	18041-20001-34473	12024 RICASOLI WAY	91326	12	216B109   373	2701084023	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	PIN	34.29188411	-118.58500462	10/9/2018changes to an approved set of plans.  changes to add (3) tesla powerwalls 5KW to the existing pv system.plan check for power only.PV1.  Install 14.95 kW roof mounted grid tied PV system.  (46) modules with 11.4 kW rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57268	12041-10000-19576	6600 N TOPANGA CANYON BLVD #1049	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	2,868 SF RETAIL SPACE IN TOPANGA.  T.I. REMOEL,  DISPLAY FOR ELECTRIC VEHICLE ONLY.   Load is less than 400Amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57269	19041-20000-52228	13212 W ERWIN ST	91401	2	177B157   442	2331025017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.18293	-118.42097	PV1. INSTALL 7.56 KW DC PV SYSTEM WITH (24) MODULES, (1) INVERTER (7.6KW), AND (2) TESLA ENERGY STORAGE SYSTEMS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57270	11041-10000-25363	1321 E WHOLESALE ST	90021	14	124-5A215  11	5164010005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.03652	-118.23498	Equipment replacement & Control upgrade for banana ripening room.  PLAN CHECK ONLY for Energy, no Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57271	14041-10000-32901	3150 W SAN FERNANDO ROAD Suite 5	90065	13	153B209   408	5458002013	[Q]C2-1VL-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.11582	-118.24713	Plan check for Title 24 only. Project site is a commercial space (not first time tenant; space will stay commercial). Total lighting area = 523 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57272	19041-20000-41576	22540 W JEFFREY MARK CT 3	91311	12	204B097    15	2724004***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	02/08/2020 12:00:00 AM	ADDRESS	34.2564	-118.61793	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING APARMENT UNIT 3. SYSTEM SIZE IS 9.25KW DC/7.6KW AC. SCOPE OF WORK CONSISTS OF (25) PV MODULES WITH OPTIMIZERS AND A 7.6 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57273	14041-20001-31034	5048 N SHIRLEY AVE	91356	3	171B117   452	2175033007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	34.16233	-118.55683	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 19.6 DC.(60) SUNPOWER 327W(1) SMA SB8000TL(1) SMA SB10000TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57274	16041-10000-00529	800 WORLD WAY TERM 8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	33.94305	-118.39757	REVISIONS TO PERMITTED SET OF PLANS. RELOCATED IT ROOM 8232 AND UTILITY ROOM 8232-1PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57275	17041-20000-10886	19915 W FRIAR ST	91367	3	180B113   797	2134025019	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Issued	04/19/2017 12:00:00 AM	ADDRESS	34.1866	-118.56685	pv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57276	19041-10000-45862	445 S FIGUEROA ST 22nd flr	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	08/27/2020 12:00:00 AM		Permit Finaled	03/12/2021 12:00:00 AM	ADDRESS	34.05295	-118.25675	High Rise TI.  INTERIOR RENOVATION OF (E) RESTROOMS AND ELEVATOR LOBBY INCLUDING NEW PARTITIONS, CEILING AND FINISHES. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.AREA OF WORK: 1,988 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57277	14041-20000-25870	2251 S BARRY AVE	90064	11	123B149   459	4260013012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	06/09/2015 12:00:00 AM	ADDRESS	34.03357	-118.44596	INTERIOR TI. ADDITION OF DECK. OFFICE. NEW LIGHTING AND NEW SERVICE. 600A >120/240V< 3P4W. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57278	16041-10000-35597	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	33.97615	-118.42138	PC FOR A NEW METHANE GAS DETECTION SYSTEM (LEVEL 5). SCOPE INCLUDES 58 GAS DETECTION DEVICES, AND 1 CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57279	19041-10000-02792	5306 S COMPTON AVE	90011	9	108B213   152	5105003905	OS-1XL	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	33.99463	-118.2476	PC FOR FIRE ALARM. REPLACING EXISTING FA SYSTEM . SCOPE INCLUDES NEW FA PANEL ,  1 POWER SUPPLY AND 96 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57280	18041-10000-00972	3036 N FLETCHER DR	90065	13	153A213    24	5458009900	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.11544	-118.24478	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 6250 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57281	11041-20001-01600	1565 S WESTERN AVE	90019	10	126B193   272	5073011028	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM			PC Approved	05/27/2011 12:00:00 AM	PIN	34.0437836	-118.30937412	Changes from previously approved plans.  Changes include the use of the area in lunch and grown rooms.  Plan check for energy only.*****PLAN CHECK POWER AND ENERGY INTERIOR REMODELING TO EXISTING DENTAL CLINIC*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57282	13041-20001-08610	17311 W PARTHENIA ST Pv-1	91325	12	195B133   406	2768016003	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.22872	-118.51146	New rooftop mounted PV.   2.5kW inverter and one 5kw inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57283	10041-20000-25453	2470 N FLETCHER DR	90039	13	150A209    42	5437033009	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1873.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	ADDRESS	34.1071	-118.25499	Plan check for replacing 600A meter section and new feeders to existing subpanel. Existing 600A service and all loads are existing to remain. Permit for replacing 600A meter section and misc. permit for new feeders to existing subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57284	17041-10000-24527	1076 N LILLIAN WAY	90038	13	144B185   732	5533017001	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.09035	-118.32759	PC FOR T24 ENERGY ONLY. PC FOR BAR TI, LIGHTING UPGRADES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57285	14041-20000-00443	14727 W SHERMAN WAY	91405	6	183B149   827		[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.20141	-118.45381	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57286	14041-20001-16721	1340 E 6TH ST 5th Floor	90021	14	126A217   152	5164011001	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.03813	-118.23423	"REVISIONS TO AN APPROVED SET OF PLANS.  ADDING ADDITIONAL RECEPTACLES TO UNITS 501 THRU 532.Convert entire 5th from warehouse to manufacturing on the existing building.  Install tenant panels, branch circuits, and lighting.  Plan check for power and energy.""COMPLY WITH DEPARTMENT ORDER effective date03/17/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57287	18041-10001-40491	703 E MACHADO DR	90291	11	111B145   532	4240019033	R3-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.00177	-118.47099	EXPEDITE FEE PV1, NEW ROOFMOUNTED SOLAR SYSTEM USING CENTRAL INVERTER  AND TWO NEW AC STORAGE. (1) 5KW INVERTER, (16) MODULES AND (2) 5KWAC POWERWALLS    TOTAL SYSTEM SIZE 5KWAC/5.2KWDC AND 27.0 KWH ENERGY STORAGE SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57288	16041-10001-05129	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM			PC Approved	12/09/2016 12:00:00 AM	ADDRESS	34.09783	-118.36466	12/09/2016 Changes to approved set of plans. Note changes under clouded areas as delta 2. Existing building CVS store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57289	14041-20003-05564	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	34.0352	-118.45736	Changes from previously approved plans.  Permit issued under 20000 PCIS #.  Addition of one outdoor building sign resulting in changes to title 24 compliance sheets.  Addition of kirk key interlock to give option for portable generator.*****Previous Description*****PLAN CHECK FOR ALL NEW ELECTRICAL EQUIPEMENT FOR EXISTING BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57290	18041-20000-15257	7101 N MCLAREN AVE	91307	12	183B097   247	2026004003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.19926	-118.62473	Plan check for PV roof mounted system. System size: 7.6kW with 31 modules and 1 inverter(7.6kW) connected to center feed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57291	14041-20001-11219	20020 W MAYALL ST	91311	12	204B113   498	2726022005	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	34.25351	-118.56978	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 6.5kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(26) Trina Solar #TSM-250PA05.18 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57292	14041-10000-25965	11099 S LA CIENEGA BLVD SUITE 210	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	33.93534	-118.37106	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. 3045 SQFT, EMERGENCY LIGHTING. SUITE 210.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57293	14041-20000-33557	15313 W CABRITO ROAD	91406	6	189B145   331	2654037025	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.21591	-118.46699	PLAN CHECK FOR POWER AND ENERGY. A NEW 24 UNIT APARTMENT FOUR STORY BUILDING. 1200 A SERVICE. FIREALARM VARIANCE HAS BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57294	12041-20000-30856	925 W WEST 34TH ST	90089	9	120A201    20	5039003027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.0239	-118.28647	4800V service upgrade. Fees calculated by applicant. Title 24 fees have not been paid. NORRIS DENTAL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57295	18041-10000-13075	1155 S FLOWER ST TOWER 3	90071	14	127-5A207 344	5138015045	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			07/05/2018 12:00:00 AM			Reviewed by Supervisor	07/17/2018 12:00:00 AM	PIN	34.04253434	-118.26540471	[3 OF 3]  Changes to approved set (Refer to plan check# 15041-10004-26464), Plan check fee for Tower 2 is paid under the Podium plan check fee. Only one set of plan is provided for Tower 2, Tower 3, and Podium under this SOW. Master plan #15041-10004-26464 and narrative of changes are attached to this submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57296	16041-20000-09405	8409 N FAUST AVE	91304	12	192B097   164	2004013016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.22331	-118.62051	Plan check for a PV1 roof-mounted PV system. System size is 8.6 kWac and consists of (2) inverters, (41) modules, (1) load center, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57297	12041-20000-00131	8850 N SYLMAR AVE	91402	7	195B153   541	2639018004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/22/2012 12:00:00 AM	ADDRESS	34.2314	-118.44547	Enphase inverter PV system on roof of SFD.  A variance to install Enphase M215 inverters was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57298	14041-20000-16778	1800 N HIGHLAND AVE 3rd flr	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.10436	-118.33763	Title 24 plan check only on a 3rd floor with 10,152 SQ feet of a 10stories commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57299	13041-20000-27579	23741 W KILLION ST	91367	3	174B089   597	2047010002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.16999	-118.64505	Modification to approved plans to change location of PV modules on the roof.  Og app. 13041-20000-21584.        <<<PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 11.13 KW. 42 MODULES AND 2 INVERTERS.>>>	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57300	18041-30000-42851	11601 W WILSHIRE BLVD 2ND FLOOR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/02/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR T-24  ENERGY ONLY FOR RESTOOM AND CORRIDOR TI IN A HIGH RISE BUILDIND ON THE 2NDTH FLOOR. TOTAL AFFECTED AREA 1867 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLESB#18016-10000-31082	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57301	12041-10000-09595	3900 N STANSBURY AVE	91423	4	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1417.00	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM			PC Approved	04/26/2012 12:00:00 AM	ADDRESS	34.14084	-118.44264	T.I. to an existing private school.  Load is less than 200A per applicant.  PLAN CHECK ONLY for T-24, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57302	17041-20001-10244	2828 N NEWELL ST Suite 1	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	09/12/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the fixtures being installed; changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 921 sq. ft.Note: Building permit has been pulled under 17016-10000-02810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57303	17041-10000-41957	6080 W CENTER DR 7TH-FLOOR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	33.97713	-118.39172	PC for T24 only for new lights in offices and corridors in 7th floor. Installing new lights and receptacles. Total area is 5014sqft. B# 17016-10000-27345.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57304	14041-10000-32905	9345 N GLENOAKS BLVD	91352	6	198B173    66	2538010006	M2-1-G, M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.23837	-118.37581	Plan check for T-24. Total area: 4460 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57305	13041-20001-04124	616 S KENMORE AVE	90005	10	135B197  1102	5502028006	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			05/01/2017 12:00:00 AM			PC Info Complete	06/07/2017 12:00:00 AM	ADDRESS	34.06289	-118.29646	5/1/2017changes to an approved set of plans.  changes noted delta 2.  new generator with em lighitng and associated loads in the cooridors and outside podium level only.  general lighitng fixtures changed in common areas.  plan check for energy and power.  2008 title 24. (((((Full plan check for new 57 unit apartment. Fire alarm variance has been filed. METHANE Zone.extention granted to 8/19/15)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57306	11041-10000-26524	215 N ARDEN BLVD	90004	4	138B189  1434	5515011008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	02/17/2012 12:00:00 AM	ADDRESS	34.07504	-118.32613	New 6.6KW roof mounted photovoltaic system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57307	16041-20000-44257	5331 N CORBIN AVE	91356	3	171B117   114	2164002036	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	02/21/2017 12:00:00 AM	ADDRESS	34.16748	-118.56288	Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (61) modules, (1) load center, and (2) combiner boxes.$0 permit fee is due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57308	13041-10000-18442	5601 N COMANCHE AVE	91367	3	174B113   326	2151010014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.17314	-118.57217	INSTALL ROOF MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 7.105 KW. INVERTER: POWER-ONE AURORA PVI 6000. 29 TRINA SOLAR TSM-245PC05/PA05.18 MODULES. DC UNGROUNDED TRANSFORMERLESS SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57309	16041-10000-05675	21500 W VICTORY BLVD	91367	3	180B105    57	2146005186	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.18793	-118.59894	FULL PC FOR A TI IN A RETAIL STORE, SCOPE OF WORK INCLUDES NEW LIGHTING  AND RECEPTACLES. TOTAL SQ. FT. 29982.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57310	10041-10000-17340	520 S VIRGIL AVE	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM			PC Approved	10/04/2010 12:00:00 AM	ADDRESS	34.06457	-118.28687	TI IN AN OFFICE BUILDING. PLAN CHECK FOR T24 AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57311	18041-10001-12128	729 S BERENDO ST	90005	10	132B197   320	5094009015	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			04/04/2018 12:00:00 AM			Verifications in Progress	06/14/2018 12:00:00 AM	ADDRESS	34.05886	-118.29429	EXPEDITED PER APPLICANT'S REQUEST.PV2. NEW ROOF MOUNTED PV SYSTEM ON AN APARTMENT BUILDING. 3KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57312	16041-10000-29887	1678 S STAUNTON AVE	90021	14	120A213   396	5167003034	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.02092	-118.24142	T24, REMOVE HID  FIXTURE AND REPLACE WITH LED FIXTURE. TOTAL AREA 3150 SQ FT. (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57313	19041-20000-15214	300 WORLD WAY 330 & 331	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	33.94502	-118.40714	REPLACEMENT OF A INDOOR ELECTRICAL SIGN FOR EXISTING COMMERCIAL BUILDING. LAX T-3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57314	17041-10000-16926	3670 W 3RD ST	90020	10	135B197   189	5502005055	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.06888	-118.29611	PC FOR A TI IN EXISITNG REATIL (7 ELEVEN) TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 2176 SQ.FT.SCOPE INCLUDES NEW PANELS, CIRCUITS AND LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57315	11041-10000-00198	6666 W SANTA MONICA BLVD	90038	4	144B185   760	5532025004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM			PC Info Complete	01/10/2011 12:00:00 AM	ADDRESS	34.09053	-118.33537	CHANGE OF USE FROM OFFICE/WAREHOUSE TO VETERINARY CLINIC.(~ 50' X 80') tittle 24 energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57316	19041-20000-35578	11500 W EMELITA ST	91601	2	174B169   195	2338015002	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	05/21/2021 12:00:00 AM		Permit Finaled	02/10/2023 12:00:00 AM	ADDRESS	34.17641	-118.38244	New 800 amp 120/240v 3 phase 4w service. Install new panels, equipments and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57317	09041-10004-08041	241 S DETROIT ST	90036	5	135B181    68	5513021028	RD6-1	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM			PC Approved	03/26/2010 12:00:00 AM	ADDRESS	34.06971	-118.34525	Plan check only. Supplemental is for changes to previously approved plans. Changes on single line from fully rated system to series rated system.  Panel schedules and loads to be verified in next application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57318	15041-20000-43823	23210 W CASS AVE	91364	3	165B097    31	2076015018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.15217	-118.62113	PV1 rooftop solar instalation. (38) Q-PRO BFR-G4(38) M215-60-2LL(1) load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57319	14041-20001-28745	7012 N OWENSMOUTH AVE	91303	3	183B105   617	2138008010	P-1VL-RIO, [Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM			PC Approved	11/17/2014 12:00:00 AM	ADDRESS	34.19776	-118.60139	EXPEDITE FEESPV2 COMMERCIAL ROOFTOP SOLAR. USING ENPHASE MICROINVERTER MODEL 215. TOTAL SIZE 10.75KW AC UISNG 50 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57320	19041-20000-32391	5222 W SUNSET BLVD	90027	13	147A195   114	5544034037	C2-1D	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM			PC Info Complete	08/19/2019 12:00:00 AM	ADDRESS	34.09794	-118.30402	T24 PLAN CHECK FOR TI TO EXISTING COMMERCIAL RETAIL. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1175 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57321	11041-10000-25390	2551 W BEVERLY BLVD	90026	13	136-5A203  98	5157001019	C2-1	Central	Westlake	Greater Echo Park Elysian		2086.20	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			PC Approved	11/29/2011 12:00:00 AM	PIN	34.0693901	-118.27601164	Title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57322	19041-20001-34460	10975 W BLUFFSIDE DR PV1	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.14171	-118.36918	PV2 BUILDING #1 (N) 18.4 KW AC/20.52 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (57) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57323	19041-10000-11450	5555 W MELROSE AVE ARCHIVE-BLDG 330	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	NEW FIRE ALARM SYSTEM IN A LOWRISE (4 FLOORS). SCOPE INCLUDES 1 FACP AND 138 DEVICES. STARTING VOLTAGE IS 29Vdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57324	17041-10000-24778	15800 W ROSCOE BLVD	91406	6	192B141   492	2673021041	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.2212	-118.47638	PC for T24 for 480/277 outdoor lighting fixtures in parking lot. Total affected are is 86,000 sqft outdoor. PC to verify squarefootage and add more area fees if applicable.Load under 400A. Building PC# 17026-10000-00172	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57325	17041-10000-37504	10108 N HALBRENT AVE	91345	7	204B145   743	2660014011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.25394	-118.46573	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWAC.(26)MODULES-LG335N1C-A5(26)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE7600H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57326	16041-10000-16671	1149 N GULF AVE	90744	15	033B205   700	7415023017	[Q]RD2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM			Corrections Issued	05/12/2016 12:00:00 AM	ADDRESS	33.78579	-118.27352	PV2 multifamily TOTAL SYSTEM SIZE 3KW AC USING 8 MODULES AND POWER OPTIMIZERS	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57327	12041-10000-24697	19301 W SUPERIOR ST	91324	12	201B117   403	2761009017	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.24649	-118.5541	New 11.20 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57328	18041-10000-30236	8256 W FOOTHILL BLVD	91040	7	204B193   150	2560009011	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Issued	08/10/2018 12:00:00 AM	ADDRESS	34.25953	-118.31333	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57329	18041-20000-44007	2239 N TALMADGE ST	90027	4	150B201   253	5591005013	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM			Not Ready to Issue	11/16/2018 12:00:00 AM	ADDRESS	34.11015	-118.28172	pv1install roof mouned pv system sized 6.4KW AC interconnected with msp.this is plan check only permit fees paid under application number 18041-90000-42243	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57330	17041-10002-10505	2697-2701 W JAMES M. WOOD BLVD	90006	1	132A201   169	5077025015	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			07/10/2019 12:00:00 AM			PC Approved	07/10/2019 12:00:00 AM	ADDRESS	34.05606	-118.28673	"DELTA ""2"" chqnges to approved plans ONLY. Changing all residential unit feeder from copper to alluminum conductors, revising load calculations due to reduction of elevator size, relocating service location, revising short circuit calculations, and relocating EV chargers on the floor plans. Note: Permit Fees are paid under PCIS#17041-10000-10505"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57331	13041-10004-11563	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM			PC Info Complete	05/06/2015 12:00:00 AM	ADDRESS	34.09818	-118.32309	((5/6/2015- changes made to approved set. Adding 2 new panels to single line diagram.)))Modifications to approved set.  Additional 800A distribution equipment.   Revised lighting layout.  Relocation of distribution equipment and loads.  (((AS PART OF THE COLUMBIA SQUARE REDEVELOPMENT, TWO BUILDINGS SHARING A CONNECTING CANOPY WILL HAVE THE CANOPY REMOVED. A BUILDING PERMIT WAS ISSUED FOR  EACH BUILDING-6125 W SUNSET BLVD HAVING 6 FLS AND 6121 W SUNSET BLVD HAVING THREE FLOORS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57332	19041-10000-08783	6600 N TOPANGA CANYON BLVD Suit 1080	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	"TI in an exiting retail ""Amazon"" store. Energy plan check only. Scope includes new lighting and equipment with a total area of 4,444-SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57333	13041-10001-29590	2485 S ARMACOST AVE	90064	11	120B149   165	4257002011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			Reviewed by Supervisor	11/04/2013 12:00:00 AM	ADDRESS	34.02776	-118.44796	Expedited RSES plan check per applicant request. ((((PV1.  Install 4 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US.  16 modules: Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57334	10041-20000-22549	3000 W 6TH ST	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown	YES	2111.20	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	12/06/2011 12:00:00 AM	PIN	34.06351748	-118.28745252	Plan check for roof mounted 11.5 KW photovoltaic system for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57335	18041-10000-12410	15244 W PARTHENIA ST	91343	6	195B145   531	2654022016	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.22811	-118.46475	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57336	13041-20000-22846	941 E 35TH ST	90011	9	115-5A209  87	5114016001	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.01191	-118.25916	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.0 KW USING 15 MODULES. NONSTANDARD PLAN. TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57337	18041-10000-01563	401 S DETROIT ST	90036	4	135B181   387	5508005028	[Q]R4-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Apartment			01/16/2018 12:00:00 AM			Reviewed by Supervisor	02/16/2018 12:00:00 AM	ADDRESS	34.06671	-118.34524	PC FOR POWER ONLY FOR AN EXISTING APARTMENT BUILDING. SCOPE INCLUDES ADDING A NEW 600A 120/240V 1 PHASE 3 WIRE DISTRIBUTION BOARD FOR REFEEDING APARTMENT UNITS AND ADDING 58 LAUNDRY CIRCUITS TO EXISTING UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57338	18041-10000-10178	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	NEW CORE AND SHELL FIRE WARNING SYSTEM FOR BUILDINGS 2 THRU 5 AT THE PACIFIC PALASADES VILLAGE.ANOTHER APPLICATION  FOR THE PLAN REVIEW FOR THE CORE AND SHELL  FIRE WARNING SYSTEM IN BUILDING 1 SHALL BE SUBMITTED; ALSO, LAFD APPROVAL STAMPS AND SIGNATURES ARE REQUIRED  ONALL  FIRE WARNING PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57339	18041-20000-23598	4120 S NAOMI AVE	90011	9	115-5A211 264	5115028004	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.10	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.00858	-118.25363	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (9) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57340	11041-20000-06048	5700 W WILSHIRE BLVD 5th floor	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	05/13/2011 12:00:00 AM		Permit Finaled	07/01/2011 12:00:00 AM	ADDRESS	34.06218	-118.35303	T.I. to a high rise building.  Install general/emergency lighting in corridor of 5th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57341	11041-10000-03125	5705 W 98TH ST BLDG 5705	90045	11	093B169   345	4125024022	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	05/02/2011 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	33.94752	-118.3811	CHANGE OF PORTION OF EXISTING WAREHOUSE USE TO RESEARCH LABORTARY.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57342	14041-20002-07399	11550 N INDIAN HILLS ROAD	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.27998	-118.45874	Change of inverter from PowerOne Trio 27.6 kW to Chint Power CPS SCA28KTL-DO/US-480 and substitution of solar load center with fused disconnects and gutter tap.  (((PV2 110.4KWAC SYSTEM FOR COMMERCIAL SPACE. BUILDING APPROVAL IS REQUIRED BEFORE PERMIT CAN BE ISSUED.)))(($0 plan check fee due to senate bill 1222 from 2012)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57343	11041-10000-01437	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	33.89279	-118.28725	New Fire alarm and panel 3 story commercial building.  Full evacuation.  1 alarm panel and 271 devices.  This building previously carried an application under 10041-10000-21175 for fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57344	19041-20000-51365	23501 W ARMINTA ST	91304	12	189B093   456	2020004040	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.21339	-118.63867	PV1.  Install 13.87 kW DC / 11.4 kW AC roof mounted PV system.  (38) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57345	13041-20000-00167	1302 N CHEROKEE AVE	90028	4	144B185   105	5547030024	R3-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	34.0946	-118.3351	New 5.52KW rooftop mounted PV system for an existing single family residence.   System is ungrounded/transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57346	15041-20000-11136	10429 W VENICE BLVD	90034	5	117B165    88	4314003042	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.02032	-118.4049	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 810 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57347	18041-10001-16323	10250 W SANTA MONICA BLVD #2330	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"[[8/9/18 CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA ""3"" AND ""4"" CHANGES .  MINOR CHANGES TO LIGHTING AND LOAD]]]Full plan check for first time tenant ""Volcom"" in Westfield Cetury City. Install (3) panelboards, and (1) 30 kVA transformer. Power fed from DB-ELA 44. Total area: 2,536 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57348	18041-10000-38323	22505 S NORMANDIE AVE	90501	15	045B197    11	7347006030	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	33.82181	-118.29928	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57349	14041-20000-35501	3431 S REDONDO BLVD	90016	10	120B177   846	5047008014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.02447	-118.35946	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. Using 300W power optimizers.24 235/250W pv modules across two strings (12+12).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57350	12041-20000-24814	3821 N DIAMANTE PL	91436	5	162B137   399	2293002013	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2012 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.13935	-118.49547	PV1 10.29KW DC. GRID-TIE ROOF MOUNTED W/O ENERGY STORAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57351	17041-10001-19841	7320 N FIGUEROA ST	90041	14	162A229   338	5481013029	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			Reviewed by Supervisor	06/20/2017 12:00:00 AM	ADDRESS	34.13633	-118.18806	Expedite fees only.       Installation of new roof mounted solar PV system on existing commercial building.  Microiverter system.  Total size = 12.75 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57352	16041-30000-26312	6719 N MELVIN AVE	91335	3	180B117   174	2132005012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.1926	-118.55975	PV1ADDITION TO AN EXISTING PV SYSTEM. ROOF MOUNTED 3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57353	14041-10000-08542	9341 N KESTER AVE	91402	6	198B149   204	2650032052	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.24053	-118.45605	PV1 ROOFMOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57354	15041-10000-15254	6150 W 96TH ST	90045	11	093B165   121	4124027906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	33.94871	-118.39284	CONNECT NEW FEEDERS TO EXISTING 600 AMP DISTRIBUTION BOARD TO ENERGIZE MODULAR TRAILERS ((UNDER SEPARATE PERMIT)) AND SITE LIGHTING FOR OPEN PARKING LOT.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 107,600	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57355	15041-10000-37357	21030 W GRESHAM ST BLDG 2	91304	3	195B105   139	2779003050	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Expired	12/06/2017 12:00:00 AM	ADDRESS	34.23048	-118.59195	BUILDING 2 OF TWO BUILDINGS.  FEES PAID UNDER APPLICATION NUMBER 15041-20000-29377((PLAN CHECKING FOR NEW DESIGN. PV2 COMMERCIAL ROOFTOP SOALR. PC 108 MODULES, 3 CENTRAL INVERTERS AND LOAD CENTERS. PV TO INTERCONNECT TO EXISTING SERVICE. NET METERED. TOTAL SYSTEM SIZE 27KW AC))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57356	16041-20000-39085	11153 W TUXFORD ST	91352	6	195B173   131	2408035008	[T][Q]M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM			PC Approved	11/03/2016 12:00:00 AM	ADDRESS	34.23248	-118.37448	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is lighting for bathrooms only. Total lighting area = 1,777 sq. ft.Note: Building application has been created under 15016-20000-13724	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57357	18041-10000-10145	15273 W DE PAUW ST	90272	11	126B125   822	4412028029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Issued	04/30/2018 12:00:00 AM	ADDRESS	34.03865	-118.52584	PC FOR TWO ENERGY STORAGE SYSTEMS (TESLA POWERWALL 5.8kVA each) IN A SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57358	13041-10008-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	04/13/16Changes to an approved set of plans, note changes on delta 35. Changes include the addition of 3 security gate circuits, change fuse to a type L and addition of a receptacle. (((03/29/16Changes to an approved set of plans, Note changes on delta 34. Changes include the removal of light fixture and addition of a smoke guard door circuit. )))(((10/18/2015Changes to an approved set of plans. Changes are cluded on delta 28. Changes include the relocation of the inverter battery cabinet and adding block splices from MSB to RA-2. PC only.  )))(((REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  )))((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57359	16041-20000-26200	3501 S TROUSDALE PKWY 3rd Floor	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.02194	-118.28455	TI to (E) 3rd floor university admin offices and storage room.  Plan check for energy.  443 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57360	13041-10000-35535	6577 S 4TH AVE	90043	8	102B189   164	4008005007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	33.97923	-118.32174	PV1, Install 3.75 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (15) modules: Yingli YL250p-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57361	19041-10000-19569	5500 W JEFFERSON BLVD	90016	10	120B173  1730	5047015033	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.02557	-118.3665	T-24 CHECK FOR OFFICE TI , AREA OF SCOPE IS 818 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57362	19041-20001-34231	2624 S PALM GROVE AVE	90016	10	123B181  1180	5057010022	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.0317	-118.34514	09-11-2019 Changes to an approved set of plans per inspector correction notice for as-builts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57363	15041-10000-02409	1701 E WASHINGTON BLVD	90021	14	118-5A213   9	5167002059	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.02073	-118.24257	Title 24 plan check only.  Total area = 8,730 sq. ft.T.I. to existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57364	14041-10001-19956	5530 E VALLEY BLVD	90032	14	138A237    30	5221013038	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	34.07423	-118.16225	Change to approved set by removing panel F from the main plan and all  lightings and sign from the canopy area. All changes are under delta-1 only.(((PC FOR POWER AND ENERGY. NEW 7 ELEVEN WITH A RETAIL STORE 14010-10000-02403:DISPENSERS AND CANOPY UNDER APPLICATION14041-10000-32528ESTIMATION OF THE # OF DEVICES PER APPLICANT REQUEST AND ADDING THE MISSING PANELS DUE TO UNSHOWN PANEL SCHDEULES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57365	16041-10000-37478	777 S FIGUEROA ST STE 2600	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.04828	-118.26116	TITLE 24 ONLY FOR EXISTING HIGH-RISE COMMERCIAL BUILDING (SECOND FLOOR SUITE # 2600).TOTAL SQ. FT. 4964	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57366	10041-10000-10210	1925 S CENTURY PARK EAST Suite#2050	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM			PC Info Complete	05/28/2010 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI in an existing office area on the 20th floor, Suite #2050. Plan Check is for T-24 Energy Calcs & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57367	12041-10000-02700	2020 S BUNDY DR	90025	11	123B149   367	4259020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Public Safety Only			02/06/2012 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	12/26/2014 12:00:00 AM	ADDRESS	34.03347	-118.45477	INSTALLATION OF A FIRE WARNING SYSTEM WITH CENTRAL STATION SYSTEM FOR A COMMERCIAL STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57368	12041-10000-09171	8723 W ALDEN DR	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.0754	-118.38272	New switch boards, 625 kva generator, , mechanical equipment, circuits for first floor of  an existing 2-story, Cedar's Sinai Laboratory building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57369	17041-10001-34706	3201 S HOOVER ST Suite 1870	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	REVISED PERMITTED SET OF PLANS TO INCLUDE CORRECT SUITE NUMBER AND REVISED LIGHTING PLANS AND TITLE 24 COMPLIANCE FORMS  FOR CHANGES TO THE LIGHTING SYSTEM.((((((((PC FOR FIRST TIME TENANT FOR A RESTAURANT (THE VILLAGE AT USC) FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57370	19041-10000-29912	380 WORLD WAY SPACE T56	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC for T24 only, scope of work is a TI new load under 400A. Scope of work includes new lighting, controls, and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57371	15041-10002-23931	11970 N SHOSHONE AVE	91344	12	216B129   204	2601051004	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.28871	-118.51716	CHANGES TO AN APPROVED SET, CHANGES NOTED ON DELTA 1. CHANGES INCLUDE REPLACEMENT OF A 3KW INVERTER TO A 5KW INVERTER. NOTE: FEES ARE  $0 DUE TO SENATE BILL 1222(((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECETD WITH MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57372	14041-10000-13278	6555 W FOOTHILL BLVD	91042	7	201A203   106	2570019008	C2-1VL, P-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			05/19/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.24594	-118.27468	TI FOR EXISTING SMART AND FINAL. PLAN CHECK FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57373	18041-10000-12193	11350 W PALMS BLVD	90066	11	117B157   350	4249026028	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	11/17/2021 12:00:00 AM	ADDRESS	34.01769	-118.42601	PC FOR REPLACMENT OF FACP FOR EXSITING FA SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57374	14041-10000-11953	15435 W VANOWEN ST	91406	6	183B145   732	2234025016	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Apartment			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.19405	-118.46976	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57375	18041-10000-02098	7708 N SEPULVEDA BLVD	91405	6	189B145   681	2209033059	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.21043	-118.46597	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57376	15041-10000-12294	517 N FAIRFAX AVE	90048	5	141B177  1096	5527020007	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	PIN	34.0805721	-118.36179	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHT NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOE ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57377	16041-20000-23305	3118 N JOHNSTON ST	90031	1	141A225    79	5206019005	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.08193	-118.20766	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57378	10041-10000-19239	701 E NEW DOCK ST	90731	15	024B209   298		[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2961.00	Electrical	Electrical	Public Safety Only			09/28/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	03/23/2011 12:00:00 AM	ADDRESS	33.75567	-118.25325	NEW FIRE WARNING SYSTEM FOR A 4-STORIES COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57379	18041-20000-01542	6530 N LANKERSHIM BLVD UNIT R & S	91606	2	180B169   731	2335009022	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Issued	02/14/2018 12:00:00 AM	ADDRESS	34.18952	-118.38758	Tenant improvement of commercial restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57380	16041-10000-37830	555 W 92ND ST 1-46	90044	8	094-5A201 151	6039016029	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	33.95296	-118.28418	INSTALLATION OF NEW FIRE ALARM SYSTEM . 200 FA DEVICES AND ONE FIRE ALARM PANEL, 2 REMOTE POWER SUPPLY, ONE COMMUNICATOR AND ONE ANNONCIATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57381	16041-20001-40732	5342 N SHOSHONE AVE	91316	5	171B129    33	2257003002	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2017 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.16828	-118.51615	1.25.2017 - Recheck standard plan due to customer losing the original approved/stamped set.======pv1install rof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57382	16041-10001-21088	400 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.04446	-118.25616	"This is Plan check only for a lost master plan. Permit shall be issued under 16041-10000-21088Restaurant remodel on existing commercial space. Change of use from nightclub/restaurant to a restaurant ""Shake Shack"". This is full plan check, total affected area: 2,767 sq.ft((B# 16016-40000-11947))"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57383	16041-30000-45045	5327 N HERMITAGE AVE 1-7	91607	2	171B165   215	2347025013	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.16757	-118.40046	Plan check for a new fire alarm system for a 4-story, 42-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (142) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57384	19041-10000-53689	11502 W CUMPSTON ST	91601	2	174B169  1253	2350010015	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Apartment			12/30/2019 12:00:00 AM	07/27/2020 12:00:00 AM		Permit Finaled	04/21/2022 12:00:00 AM	ADDRESS	34.16955	-118.38246	Full plan check for New apartment units, service size is 800A, 120/240V, 3phase, 4wire. area of scope 7420SF***********************************************************************************NEW 3 STORY 12 UNITS APARTMENT WITH OPEN ROOF DECK OVER BASEMENT GARAGE (TYPE VA/IA CONSTRUCTION, R2/S2 OCCUPANCY) _ BUILDING SHALL BE FULLY SPRINKLER W/ NFPA 13.  _1 extremely low, 1 very low, 1 low, and 1 market rate RSO unit required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57385	18041-20000-45018	6216 W LA MIRADA AVE	90038	13	144B189   258	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Issued	02/12/2019 12:00:00 AM	ADDRESS	34.09333	-118.32514	Plan check for a PV2 roof-mounted PV system. System size is 35 kWdc/34.2 kWac and consists of (3) inverters, (100) modules, and (1) load center.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57386	19041-10000-45430	700 W 7TH ST U270-S270	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	34.04797	-118.25815	New Fire Alarm System with 306 devices networking with existing FA system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57387	16041-20000-11973	22701 W CLARENDON ST	91367	3	174B097   887	2040020013	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Expired	05/30/2018 12:00:00 AM	ADDRESS	34.16934	-118.62132	"""$0 permit fees due to senate bill 1222""Install a roof-mounted solar array on a SFD and it's detached garage. Interconnect with a 225A MSP.System size: 14kW (3+5+6). Ungrounded system. (44) 327W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57388	12041-20000-13284	139 S KINGS ROAD	90048	5	138B173   758	5511015017	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Approved	06/07/2012 12:00:00 AM	ADDRESS	34.07325	-118.3723	T.I. to beauty salon.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57389	11041-10000-10418	4703 W BEVERLY BLVD 1-6	90004	4	138B193   403	5522033012	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			05/20/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.07643	-118.31152	21 devices and one panel , for two story 6 units appartment bldg	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57390	16041-20000-45640	5645 N LINDLEY AVE	91356	3	174B125   293	2157008072	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM			Reviewed by Supervisor	02/02/2017 12:00:00 AM	ADDRESS	34.17359	-118.52746	Plan check for power and energy. Alteration to existing senior assisted living housing apartment. Converting 15 guest rooms into 3 new recreation rooms, one new employee room, and 8 new assisted living units. New lighting (incl. emergency). >400A of new load. T24 area: indoor - 10,790sqft; outdoor - ~4,000sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57391	12041-20000-30637	19300 W RINALDI ST SUITE L	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.27414	-118.55457	Plan check for energy and emergency lighting. 12065 sqft. Suite L.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57392	12041-10000-02647	3680 W WILSHIRE BLVD suite# 103	90010	10	132B193    65	5093006028	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM	04/06/2012 12:00:00 AM		Permit Finaled	05/25/2012 12:00:00 AM	ADDRESS	34.06149	-118.30603	TI in a office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57393	18041-20000-12816	3726 S KELTON AVE	90034	5	117B161   629	4252025030	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			04/09/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	10/04/2020 12:00:00 AM	ADDRESS	34.01739	-118.4127	PC power and energy for 3 story 5 unit apartment with subter. garage. Installing 600A 240/120V service, panels, lights, receptacles and equipment. Building#17010-20000-00302. Total area 6024sqft. Read comments for additional information.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57394	11041-10000-09371	"11154 W AQUA VISTA ST Blgd ""A"""	91602	2	162B173    14	2366027152	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Public Safety Only			05/09/2011 12:00:00 AM			Ready to Issue	05/16/2011 12:00:00 AM	ADDRESS	34.14476	-118.37362	"New fire warning system for a 128 units apartment building. This permit is for the Bldg ""A"".  <<<<<Permit for Bldg ""B"" 11041-10001-09371>>>>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57395	14041-20000-07808	7307 N FIGUEROA ST STE 202	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.13662	-118.18837	T. I. FOR (E) 1,959 SF RESTAURANT. PC FOR T24 ENERGY ONLY. NEW LIGHTING. LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57396	14041-10000-07297	6100 W CENTER DR SUITE 800	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	33.97733	-118.3922	PLANCHECK FOR T24 ENEGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. HIGHRISE. SUITE 800. 6292 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57397	19041-10000-53900	1149 S HILL ST STE 900	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	03/13/2020 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.03926	-118.26099	Enegy PC only , area of scope 6508Sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57398	19041-30000-09293	2049 S CENTURY PARK EAST 32nd Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is the 32nd floor of an existing high-rise building. Project scope is a tenant improvement. Total lighting area = 24,020 sq. ft.Note: Building permit has been issued under 18016-10000-37771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57399	19041-10000-40246	6180 N LAUREL CANYON BLVD #D130	91606	2	177B165  1105	2334011029	(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	01/22/2020 12:00:00 AM		Permit Finaled	09/15/2021 12:00:00 AM	ADDRESS	34.18261	-118.39631	FULL PLAN CHEC5 FOR POWER AND ENERGY. SCOPE INCLUDES 45KVA TRANSFORMER, NEW TWO 200A PANELBOARDS, NEW CIRCUITS, AND NEW LIGHTING. TOTAL AFFECTED AREA IS 1301SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57400	19041-10000-16983	21040 W NORDHOFF ST	91311	3	195B105    24	2779048004	[Q]MR2-1, [T][Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	07/24/2019 12:00:00 AM	ADDRESS	34.23524	-118.59224	PLAN CHECK FOR A ROOF MOUNTED 333KVA PV2 SYSTEM CONSISTING OF 4 INVERTERS(3-SE99.9K-US & 1-SE33.3K-US) WITH 1065 MODULES USING 533 OPTIMIZERS(P850)PLANS TO BE ASSIGNED TO EDWIN OR JOHN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57401	17041-10000-36881	1327 W 71ST ST	90044	8	102B197   960	6014032022	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	33.9755	-118.29898	PC FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE 3.2KWDC 3.0 KWACSCOPE INCLUDES NEW SINGLE INVERTER WITH 8MOUDULES AND OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57402	13041-20000-05980	9420 N RESEDA BLVD #6	91324	12	198B125   131	2764010041	(Q)C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM	03/08/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.24152	-118.53589	T.I. and change the use of (E)18' x 60' portion of retail space into take-out restaurant.  Lighting and loads.  NOT A FIRST TIME TENANT SPACE PER APPLICANT.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, NO EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57403	15041-20000-27369	15020 W FLORENTINE ST	91342	7	219B149   782	2611028005	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.29423	-118.45883	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (22) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57404	16041-10000-09394	9570 W PICO BLVD PV-1	90035	5	132A167   257	4306002022	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.05499	-118.39734	PV2 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH A PERFOMANCE METER. (56) MODULES AND (2) FRONIUS INVERTERS AT 10KW. TOTAL SYSTEM SIZE 20KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57405	16041-10000-32735	6334 W ARIZONA PL	90045	11	102B165    44	4110013006	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	33.97934	-118.39757	"PC FOR TI  AND TITLE 24A COMMERCIAL BUILDING (SINGLE STORY)SCOPE OF WORK INCLUDES NEW ""MSB"" @800 AMP, PANELS,  LIGHTS AND RECEPTECALES.TOTAL AREA 34,289 SQ.FT FOR INDOOR AND OUTDOOR."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57406	14041-10000-03875	2207 W 75TH ST	90043	8	102B189  1776	4009009023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	33.97198	-118.31813	PV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. POWER OPTOMIZERS. ONE STORY. SYSTEM SIZE: 4 KW DC.(16) CANADIAN SOLAR # CS6P-250PX(16) SOLAREDGE OP300(1) SOLAREDGE SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57407	19041-10000-32809	6251 N CREBS AVE	91335	3	177B121   232	2127013044	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.18406	-118.54392	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 34 MODULES USING 9320 OPTIMIZERS AND 1 ESS(LG CHEM RESU 9.8KWH)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57408	14041-20001-05052	1183 N VERMONT AVE	90029	13	144B197   367	5540019019	RD1.5-1XL, [Q]C2-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	34.09304	-118.29194	((10/27/2014 - Supp application for changes made to approved set.  Title 24 plan check only.  Changes indicate that facility is to operate 24 hours a day.))T. I.  AND  CHG OF USE FROM RETAIL TO LAUNDRY.PC FOR POWER AND ENERGY. NEW LOAD GREATER THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57409	13041-20000-18369	5311 N BABCOCK AVE	91607	5	171B161   255	2346013038	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.16702	-118.40652	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.7 KW USING MICROINVERTER ENPHASE M215. STANDARD PLAN. TOTAL OF 22 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57410	14041-10001-21615	1754 W SLAUSON AVE	90047	8	108B193  1385	6002001001	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	33.98899	-118.30847	Plan check only. SIGNIFICANT DESIGN CHANGE to switchgear; number of circuits stayed the same. FEES ON ORIGINAL PLANS and permit should only be pulled on original application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57411	17041-30000-08536	2029 S CENTURY PARK EAST Suite 2920	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is an existing tenant space in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,505 sq. ft.Note: Building permit has been pulled under 17016-10000-03518	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57412	16041-10000-40303	1060 S CRENSHAW BLVD	90019	10	129B189   150	5081004012	C2-1-O	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.05319	-118.32361	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTING 2 STORY OFFICE BUILDING.  SCOPE INCLUDES NEW PANELS, NEW HVAC EQUIPMENT, AND NEW RECEPTACLES. NEW CONNECTED LOAD >400A. TOTAL AFFECTED AREA IS 20,565 SQ. FT. . B#16016-10000-25934	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57413	13041-20000-01525	21330 W VENTURA BLVD	91364	3	171B105   115	2167002003	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Closed	02/27/2013 12:00:00 AM	ADDRESS	34.1675	-118.59669	Plan check for energy and emergency lighting. Lamborghini dealership. 1932 (outdoor) + 6064.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57414	17041-10000-26199	232 E 2ND ST Unit B	90012	14	129A213    28	5161024034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			Corrections Issued	08/01/2017 12:00:00 AM	ADDRESS	34.0495	-118.24258	VOIDED. THE SPACE IS FIRST TIME TENANT. SEE SUPP. FOR FULL POWER AND ENERGY SUBMITTELPC for T24 only for restuarant TI. Installing one new panel, new circuits and equipment. Total affected area of 1980 sqft. Building #17016-10000-10743.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57415	13041-20000-26633	1150 N HIGHLAND AVE	90038	4	144B185   530	5532020003	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.09211	-118.33841	PC FOR T24 ENERGY ONLY. OFFICES. NEW LIGHTING. PERMIT TO BE ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57416	17041-20000-14651	13312 W MAGNOLIA BLVD	91423	4	171B157   642	2359001022	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Issued	05/03/2017 12:00:00 AM	ADDRESS	34.16472	-118.42285	Plan check for solar pv system, roof-mounted on SFD.7.6kW ungrounded system. (31) 295W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57417	16041-20000-45855	924 1/4 N MALTMAN AVE	90026	13	142-5A203 492	5427022030	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.085	-118.27959	pv1install roof mounted pv system sized 3.8kw inteconnected with msp.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57418	13041-20000-30297	20419 W DEVONSHIRE ST	91311	12	204B109    57	2707014002	(Q)C1-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.25742	-118.57823	PLAN CHECK FOR POWER AND ENERGY FOR TI OF EXISTING RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57419	11041-10000-12713	843 W PACIFIC COAST HWY	90710	15	036B197   995	7413031021	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	02/20/2013 12:00:00 AM	ADDRESS	33.79133	-118.29049	CREATE A NEW 1,500 SQ FT.  RESTAURANT FROM PART OF AN EXISTING RETAIL SPACE.  NEW SERVICE, PANEL, EQUIPMENT.  FULL PLAN CHECK.   (New service not determined @ submittal, 7/13/11)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57420	14041-20001-07201	10954 N WHITEGATE AVE	91040	7	210B193   765	2552016026	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.26861	-118.30517	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57421	10041-10002-05484	1241 N VINE ST	90038	13	144B185   204	5533005001	C2-1D, RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/03/2011 12:00:00 AM	ADDRESS	34.09373	-118.32682	Changes to approved plans.  TITLE 24 AND EMERGENCY LIGHTING , COFFEE SHOP. COMPLETE EPC MAY BE REQUIRED, SUBJECT TO FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57422	11041-10000-20811	8500 W BEVERLY BLVD # 628	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT OF AN (E) 12,000 S.F. RETAIL SPACE IN A COVERED MALL. plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57423	15041-10000-16284	3700 N COLDWATER CANYON AVE 1ST FL	91604	2	162B161   397	2384007005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	34.13809	-118.41286	NEW LUMINAIRES IN OFFICE/CORRIDOR  IN COPSES POOL HOUSE  ON THE HARVARD WESTLAKE CAMPUSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57424	16041-20000-29717	15760 W VENTURA BLVD STE 1800	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.1552	-118.47684	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  TOTAL SQUARE FOOTAGE 1743.  PLAN CHECK FOR ENERGY AND EM LIGHITNG.SCOPE IN SUITE 1800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57425	13041-10001-06027	1333 1/2 N WATERLOO ST	90026	13	141A207   127	5424023005	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.08138	-118.26534	MODIFICATION TO APPROVED SET OF PLANS. CHANGE TO MODULE TYPE FROM TRINA SOLAR # TSM-240PA05 TO TRINA SOLAR # TSM-245PC05.***************************************************************PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. PART OF MULTI FAMILY COMPLEX. THIS APPLICATION IS IN CONJUNCTION WITH TWO OTHERS. TOTAL SYSTEM SIZE FOR THIS APPLICATION IS 1.68 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57426	15041-20000-10041	12452 W OSPREY LANE #2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	Installation of new roof mounted solar PV array on 3 unit apartment building (triplex).  Each unit panel is fed by a seperate inverter (3 inverters total).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57427	15041-20000-41065	7644 N FARRALONE AVE	91304	3	186B101    34	2012021072	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.20945	-118.61016	T-24, PC FOR ENERGY. TI TO EXISTING COMMERCIAL BUILDING (GUARD SHACK). SCOPE INCLUDES ADDING NEW LIGHTING TO AN 8' X 10' GUARD SHACK. GUARD SHACK IS LOCATED BY THE ENTRANCE OF A CHURCH/SCHOOL DRIVEWAY. TOTAL AREA IS 96 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57428	15041-10001-27106	12452 W OSPREY LANE Unit #2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	EXPEDITE PER APPLICANT REQUESTPV2 installed roof mounted pv system for UNIT #2. Size 3KW, interconnected with the main service panel.(8)modules: SPR-230NE-BLK-D(1)PVI 3.0-OUTD-S-US inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57429	11041-20000-10672	18933 W LA MONTANA PL	91356	3	168B121   598	2176029032	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Expired	09/24/2013 12:00:00 AM	ADDRESS	34.1583	-118.54625	Plan check power ground mounted Photovoltaic system with 19.11 KW for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57430	13041-20000-08467	3207 S SAN PEDRO ST	90011	9	118-5A207 425	5120020017	[Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Info Complete	05/15/2013 12:00:00 AM	ADDRESS	34.01676	-118.26466	Plan check for power and energy. Golden State Laundry Systems.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57431	17041-10000-09579	300 WORLD WAY LT3-04-F3-07	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	TI IN TERMINAL 3, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN THE DELTA CLUB AREA. EXISTING LIGHTING WILL BE REMAINING WITH NEW DECORATIVE LIGHTING. TOTAL SQ. FT. 4200.  BUILDING PERMIT # 16016-10004-11866.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57432	13041-20000-29694	3650 W MARTIN LUTHER KING, JR BLVD SUITE 241	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	pc for t24 energy only. total area 1117 sq ft. hair salon	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57433	15041-10004-33019	3350 W WILSHIRE BLVD	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	06/26/2020 12:00:00 AM		Permit Finaled	11/25/2020 12:00:00 AM	ADDRESS	34.0615	-118.29586	"DELTA ""22"" CHANGES TO APPROVED PLANS. CHANGING THE SIZE OF THE EMERGENCY GENERATOR FROM 350KW TO 500KW. CHANGING THE SIZE OF THE FIRE PUMP FROM 100HP TO 125HP PLUS OTHER VAROUS CHANGES IN THE SYSTE. (PLAN CHECKER: FY)(((((CONVERSION OY 12-STORIES/BASEMENT OFFICE/GARAGE TO 216 ADAPTIVE REUSE UNITS AND RETAILS ON THE 1ST FLOOR.BLDG PERMIT 13016-10000-26033"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57434	13041-10000-16852	12505 W SHELDON ST	91352	6	195B165   332	2634006904	(T)(Q)RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			Corrections Issued	06/26/2013 12:00:00 AM	ADDRESS	34.23089	-118.40556	New bathroom building in outdoor park.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57435	19041-10000-23352	155 S LAYTON DR	90049	11	135B145   327	4365004032	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.06769	-118.46857	T-24 PLAN CHECK FOR  A CHANGE OF USE FROM SNACK BAR TO LOCKER ROOM, RESTROOM AND OFFICE SPACE. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFCTED  AREA IS 1085 SQ.FTB# 19016-10000-09362	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57436	12041-10001-26604	18515 W BURBANK BLVD	91356	3	174B125   373	2160003039	C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM			PC Approved	06/21/2013 12:00:00 AM	ADDRESS	34.1725	-118.53644	Modification to approved set: changes to lighting fixtures A, B, and C from fluorescent fixtures to LED fixtures.  Original Work Description: TI IN AN EXISTING GAS STATION. INSTALL NEW PANEL & LOAD IN HAZARDOUS AREA. PLAN CHECK FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57437	14041-10006-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	33.95605	-118.38499	CHANGES TO APPROVED SET. CHANGES STILL ALL CLOUDED DELTA 6. UNDER THIS APPLICATION, CHANGE IS ONLY TO INCLUDE AN EXISTING 200A SERVICE TO 5000A TAP BOX. UPDATED LOAD CALCULATIONS AND FEEDER DIAGRAM PROVIDED. PC ONLY, PERMIT UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57438	19041-10002-14630	1494 N MORAGA DR	90049	5	147B145   212	4377039007	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	34.09492	-118.46897	DELTA 1 CHANGES TO AN APPROVED SET TO SHOW THE PV PERFORMANCE METER ON THE PLANS AND PROVIDE LOAD CALCULATIONS PER INSPECTOR REQUEST. PC for PV, system includes 66 modules (LG365Q1C-A5) W/Optimizers (solar edge-P370). (2) solar edge inveter ( SE10000H-US) and 1 new 200A sub-Panel. $0 fees due to senate bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57439	14041-10001-21985	2173 N MANDEVILLE CANYON ROAD	90049	11	138B133   334	4492003004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.07395	-118.49976	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(15) MODULES: KYOCERA KD 255GX(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57440	18041-20000-00039	15555 W SATICOY ST	91406	6	189B145   706	2222005001	RA-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.20861	-118.47223	PLANCHECK FOR T24 ENERGY. FIRE DAMAGE REPAIR FOR APPORXIMATELY 10% DAMAGE OF (E) CHURCH. 1964 SQFT.BUILDING PERMIT # 17016-20000-23519	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57441	10041-20000-25162	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	12/07/2011 12:00:00 AM		Issued	12/07/2011 12:00:00 AM	ADDRESS	34.04342	-118.25478	"Service upgrade from 600 Amp to 2000 Amp.  Install switchboard and subpanels.  No branch circuits and lighting are install.  Plan check for power only.""COMPLY WITH DEPARTMENT ORDER effective date07/14/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57442	14041-20000-04873	11008 N MONTGOMERY AVE	91344	12	210B141   730	2667005013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.27023	-118.48133	Roof mounted PV system with 2.43KWdc (Microinvert, Enphase M215 model)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57443	11041-20000-12098	10201 W PICO BLVD BLDG#24	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM			Corrections Issued	06/19/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	Plan check power for new substation Building #24 FOX Chiller Plant Upgrade	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57444	17041-20000-09228	12303 W MONTAGUE ST	91331	7	204B165   175	2537005016	M2-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.2551	-118.40128	PLANCHECK FOR INSTALLTION OF A NEW ELECTRICAL ROOM, PIPING, AND COMPRESSED NATURAL GAS EQUIPMENT FOR FUELING TRASH TRUCKS. HAZARDOUS CLASSIFICATION.BUILDING PERMIT # 17026-20000-00113 , 17010-20000-01227	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57445	10041-20000-03151	11726 W SAN VICENTE BLVD 650	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	02/23/2010 12:00:00 AM		Permit Finaled	03/03/2010 12:00:00 AM	ADDRESS	34.05328	-118.46625	T.I WORK FOR OFFICE SPACE. THIS P/C IS FOR TITLE 24 ENERGY ONLY.  There is existing permit with out lighting of permit number 10041-20000-00852.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57446	19041-10000-46488	6200 W SUNSET BLVD	90028	13	147A189    60	5546025001	(T)(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	06/29/2020 12:00:00 AM		Permit Finaled	06/29/2022 12:00:00 AM	ADDRESS	34.09779	-118.32422	FULL PLAN CHECK FOR A NEW MIXED USE 7-STORY 270 UNITS BUILDING. SCOPE INCLUDES 2 NEW SERVICES (5000A 208/120V 3PH 4W , 2500 277/480V3PH 4W).  TOTAL AFFECTED AREA IS 55628 SQ.FT ((((BUILDING PERMIT #: 19010-10000-02936.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57447	16041-10000-03198	20316 W ACRE ST	91306	3	195B113   365	2781004027	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.22983	-118.57608	PV1, ROOF MOUNTED SOLAR SYSTEM WITH POWER OPTIMIZERS. (10) MODULES AND (1) INVERTER- 3KW. POWER OPTIMIZER IS USED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57448	15041-10001-05124	12655 W JEFFERSON BLVD	90066	11	102B161    13	4211005019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM			PC Approved	02/01/2016 12:00:00 AM	ADDRESS	33.97916	-118.41469	Supplemental change on approved set of plan, revise lighting fixtures, adding fan coils. <<Plan check for power and energy. Renovation of existing office building. Applicant approved to bring in T24 sheets and more panel schedules another day. Verify fees.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57449	19041-20000-23815	12301 W MAGNOLIA BLVD	91607	2	171B165   522	2347026001	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			06/20/2019 12:00:00 AM	11/17/2020 12:00:00 AM		Permit Finaled	09/21/2023 12:00:00 AM	ADDRESS	34.16499	-118.40092	1200A 208Y/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57450	18041-20002-41886	13254 W ARMINTA ST	91605	2	189B157  1036	2303004021	RE9-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	34.21324	-118.42245	1/9/2019changes to an approved set of plans.  changes to relocate existing equipment to rear of house.  this is plan check only.  (((Plan check for PV roof mounted system, system size: 14.4kW DC, 12.24KW AC with 40 AC Modules connected to 400A Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57451	15041-20001-27278	8907 S SEPULVEDA BLVD #8907	90045	11	096B165  1035	4122036031	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	33.95566	-118.3965	09/30/2015 Changes to an approved set of plans. The ballasts of the flourescent light fixtures have been replaced with dimmable ballasts. All changes have been clouded and marked as Delta 3.*****Previous Work Description*****Plan check for title 24 only for existing retail space. Total indoor area: 2,233sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57452	16041-20001-06143	9801 N SHOUP AVE	91311	12	201B101   242	2727004013	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2016 12:00:00 AM			Reviewed by Supervisor	03/03/2016 12:00:00 AM	ADDRESS	34.24818	-118.61505	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derating main to 150A.System size: 14kW (7+7). Ungrounded system. (52) 300W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57453	16041-10000-32756	900 N LA BREA AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.08727	-118.34386	METHANE MITIGATION FOR 8 STORY MIXED USE. MITIGATION AND METHANE ALARM PLAN PROVIDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57454	14041-10001-27492	300 S SANTA FE AVE # Q	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	Change to approved set by modifying the lighting plan and removing the partio heater load. All changes are under delta-4 only. (((Plancheck for power and energy.  First time tenant resturant. Total area 1580 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57455	18041-10000-08599	22708 W VICTORY BLVD	91367	3	180B097   634	2039020026	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Issued	03/09/2018 12:00:00 AM	ADDRESS	34.18625	-118.62139	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57456	13041-10000-02206	8500 W BEVERLY BLVD # 709	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI for existing retail space (LK Bennett London) in beverly center mall. Title 24 only and emergency circuit. 1746.5  sqrft. (PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57457	18041-20001-41260	2455 N RIVERSIDE PL	90039	13	148-5A211 125	5440026027	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.10154	-118.25327	11-20-2018 Changes to an approved set of plan. Changes include layout of modules on roof. All Changes has been clouded. Plan check only. Fees $0 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57458	16041-10000-43613	907 E 3RD ST	90013	14	129A215   276	5163006089	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.04611	-118.23458	PC FOR T24 ENERGY ONLY. NEW TRACK LIGHTS IN SHOWROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57459	13041-20000-31600	4140 W BEVERLY BLVD	90004	13	138B197   355	5518004022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.01	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.07616	-118.29977	Upgrade 600 amp service and 11 tenant sub panels in an existing comercial space.  Site is in a METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57460	14041-10000-14765	5822 E FAYETTE ST	90042	14	154-5A229  57	5484009005	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.11937	-118.19116	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57461	19041-10000-47834	4427 S GRAND VIEW BLVD	90066	11	108B157   376	4232022008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	33.9942	-118.42167	$0.00 FEES DUE TO SENATE BILL 1222 & ASSEMBLY BILL 1414 (E-PLAN)*CHANGES TO AN APPROVED SET RELOCATION OF EQUIPMENT FOR AN EXISTING SERVICE OF 225 AMPS. ORIGINAL E-PLAN PERMIT #:  19041-10000-31719REFERENCE #: 1399	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57462	15041-20002-37663	15127 W PLUMMER ST	91343	7	198B145    13	2656008014	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.24288	-118.46202	Revisions to approved set.  Changes to MSP details, interconnection of PV system method,  and roof/equipment layout.  Derating of main breaker to 175 A.  (((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 16.125KWac. (75)MODULES-HANWHA Q CELLS Q.PRO-G3 265W (75)MICROINVERTERS-ENPHASE ENERGY M215-60-S2X(1)100A SUBPANELPermit Fees $0 per California State Bill 1222)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57463	19041-20000-09690	12050 W VENTURA BLVD C-101	91604	2	162B165   141	2369015019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM			PC Approved	04/26/2019 12:00:00 AM	ADDRESS	34.14349	-118.39426	Dental office TI.  Plan check for power and energy.  NOTE: Electrical permit previously issued under 18041-90000-32158.  Permit fees paid in full.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57464	18041-10000-42409	25928 S WESTERN AVE	90710	15	033B193   240	7411001031	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	33.78725	-118.30743	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57465	11041-10000-05769	940 E 2ND ST	90012	14	129A217   202	5163006017	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			03/23/2011 12:00:00 AM			PC Approved	03/30/2011 12:00:00 AM	ADDRESS	34.04698	-118.23369	ADDING 4EA PENDANT LUMINAIRES AT INTERIOR STAIRWAYS ON 2ND FL AND LUMINAIRES FOR THE FACADE AND AT THE BUILDING ENTRANCE plan chk is for title24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57466	15041-10000-07083	3410 N GLENDALE BLVD	90039	13	156B209   359	5436005023	CM-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.1204	-118.25788	New fire alarm system with (1) fire alarm panel, (1) power supply, and (109) fire alarm devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57467	18041-20001-45049	24228 S STERLING RANCH ROAD	91304	12	192B089   200	2017039011	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.21937	-118.65502	change of address	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57468	19041-20000-31254	825 W DICKSON ST	90292	11	105B149   364	4229014063	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	33.98654	-118.45172	PV1. 5.94 KWDC/5.04 KWAC. INSTALL (18) MODULES P320 OPTIMIZERS AND (1) SOLAR EDGE (SE7600) INVERTER ON NEW 200 AMP SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57469	19041-20000-16185	22650 W CALIFA ST	91367	3	174B097   930	2040004084	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.17719	-118.62059	PV1.  Install 10.72 kW DC roof mounted grid tied PV system.  (32) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57470	10041-20000-19054	4742 N NOMAD DR	91364	3	168B113   294	2175039009	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.15674	-118.5677	Ground mounted new 13kw P.V. system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57471	14041-20001-09212	22537 W WELBY WAY	91307	12	180B097    64	2038027028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	04/24/2014 12:00:00 AM	ADDRESS	34.19296	-118.61831	EXPEDITED PLAN CHECK PER APPLICANT REQUEST(((PV1Install roof-mounted solar array, interconnect with main panel.(18) Modules - Canadian Solar #CS6P-250PX(1) 4.5kW transformerless inverter - SolarEdge #SE5000A-US-ZB-U))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57472	19041-10000-33892	21828 W MICHALE ST	91304	3	192B105    59	2779028015	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.2263	-118.60395	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 13 MODULES (HYUNDAI S365), OPTIMIZERS (SE P400) AND CENTRAL INVERTER (SE 3800H-US). SYSTEM SIZE IS 4.75 KWdc AND 3.8 KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57473	17041-20001-40108	17512 W CORINTHIAN DR	91316	5	168B129   461	2290012028	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.15687	-118.51466	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57474	11041-10000-22875	5371 E ALHAMBRA AVE	90032	14	139-5A235 198	5220017027	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM			PC Approved	11/07/2011 12:00:00 AM	ADDRESS	34.07685	-118.1687	T.I. to an existing Deli.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57475	13041-20000-14969	2515 N ROSCOMARE ROAD	90077	5	156B145   236	4378016006	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.12294	-118.46287	PV-1. Microinverters for single family dwelling. 6.88kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57476	16041-10000-05784	3909 S NORTON AVE	90008	10	117B185  1063	5033006051	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.01428	-118.33276	PV1 SFD TOTAL SYSTEM SIZE 5KW AC USING CENTRAL INVERTER SYSTEM USING SOLAR EDGE SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57477	16041-20000-38333	22728 W OXNARD ST	91367	3	177B097   532	2040002003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	02/22/2017 12:00:00 AM	ADDRESS	34.17906	-118.62183	"""0$ permit fees due to senate bill 1222""  Inspector to verify if new service and panelboard installed matches plan.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE; 24 KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57478	11041-10000-24386	956 E LAKE ST BLDG 4-3	90291	11	111B145   632	4243003036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.0012	-118.46086	Lincoln Place Apartment Building Project.  New 2-story apt. building with 4 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57479	17041-10000-40568	1030 S SANTEE ST	90015	14	126A209   256	5145020049	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Issued	11/09/2017 12:00:00 AM	ADDRESS	34.03817	-118.25562	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECKIS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57480	15041-20000-26148	19113 W LUDLOW ST	91326	12	210B121   489	2718009010	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.27033	-118.54914	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57481	19041-10000-24547	15255 W PALISADES VILLAGE LANE B1M-115	90272	11	129B125   863	4423016078	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM			PC Info Complete	06/26/2019 12:00:00 AM	ADDRESS	34.04758	-118.52462	pc (energy only) for Interior alternation to existing storage mezzanine level. area of scope 495sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57482	19041-10000-18539	2010 W JAMES M. WOOD BLVD	90006	1	130-5A203  87	5136007009	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.05289	-118.27815	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57483	16041-20000-41865	7556 N HESPERIA AVE	91335	3	186B125   213	2120021003	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.2081	-118.5261	Plan check for a PV2 roof-mounted PV system. System size is 12.6 kWac and consists of (45) modules, (45) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57484	10041-10001-17850	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Info Complete	02/11/2011 12:00:00 AM	ADDRESS	34.17126	-118.58861	New canopy and addition of passenger loading area. Plan check for T24.  <<<<<PERMIT WAS ISSUED 10041-10000-17850>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57485	11041-10000-14502	620 S MAIN ST	90014	14	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.04457	-118.25041	Per inspector, Title 24 plan check is required for both indoor and outdoor lighting.  <<<<<<<RELOCATING (8) INCANDESCENT FIXTURES AND (26) FLUORESCENT FIXTURES.  EXTENDING EXISTING LIGHTING CIRCUITS. >>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57486	13041-10000-16515	13722 W SHERMAN WAY	91335	2	183B157   987	2216027023	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM			PC Approved	06/28/2013 12:00:00 AM	PIN	34.20070651	-118.43211614	Relocation of existing 225 A subpanel for new office-type building.  2375 sq ft.  Plan check for energy only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57487	18041-10000-22071	3620 S VERMONT AVE 239 &241	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.02213	-118.29133	TI IN AN EXISTING OFFICE AREA ON THE 2ND FLOOR IN SUTE #'S 239 & 241. T-24 ENERGY ONLY.BUILDING PERMIT#: 18016-10000-18396	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57488	15041-10003-28938	14749 W VINCENNES ST	91402	6	198B149   175	2650030006	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM			PC Approved	10/18/2016 12:00:00 AM	ADDRESS	34.24038	-118.45553	change in the way main panel is configured and the way pv interconnects. to other changes. pc only. no permit needed under this application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57489	15041-10000-31497	2478 N FLETCHER DR	90039	13	150A209    31	5437033011	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.10724	-118.25482	FULL PC FOR POWER AND ENERGY, CHANGE OF USE FROM STORAGE TO RESTAURANT. NEW 800 AMP SERVICE. ADDING ANOTHER  EXISTING TENANT TO NEW SWITCHGEAR. TOTAL SQ. FT.  4726	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57490	16041-20001-21501	16830-16924 W SAN FERNANDO MISSION BLVD	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.27181	-118.49871	Revisions to approved set.  Additional subpanel and change of equipment manufacturer.   Approval for delta-2 changes only.  (((PLANCHECK FOR POWER AND ENERGY. SERVICE UPGRADE AND TENANT IMPROVEMENT FIR URGENT CARE MEDICAL CLINIC.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57491	15041-10000-41535	6300 W WILSHIRE BLVD SUITE 850	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.06319	-118.36591	PLAN CHECK FOR ENERGY ONLY FOR EXISTING OFFICE BUILDING. SCOPE OF WORK IS ON SUITE 850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57492	12041-20000-24275	800 W WORLD WAY 8A	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	PIN	33.94153561	-118.3984113	TENANT IMPROVEMENT OF EXISTING RESTAURANT. FULL PLAN CHECK (PER APPLICANTS REQUEST)  FOR POWER 7 ENERGY FOR ENGINE CO.28 RESTAURANT AT LAX TERMINAL 8 SPACE 8A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57493	13041-20000-12996	13383 W ELSIE LN	91342	7	225B157  1033	2510019073	(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	PIN	34.31283768	-118.42552268	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 1.7KW USING 8 PANELS. USING ENPHASE MICROINVERTER M215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57494	16041-10002-41399	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Approved	07/07/2017 12:00:00 AM	ADDRESS	34.27455	-118.56289	Changes to approved set per inspection. Plan check only!  All changes clouded under delta 4.  Scope inculdes revisions to title-24 form to reflect correct rating of luminaire.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57495	16041-20000-40883	15760 W VENTURA BLVD #960	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check for energy only. TI to office suite 906 in high rise building. New lighting (incl. emergency) and receptacles. 3,012sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57496	16041-20000-22269	9140 N LURLINE AVE	91311	12	198B109   129	2748001034	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.23663	-118.58406	Plan check Title 24 only in existing space office and corridor T.I. Total area: 14,480 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57497	19041-20001-49401	9560 N SUNLAND BLVD	91040	7	201B177   390	2544009***	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.24523	-118.36321	PV1.  Install 20.0 kW DC roof mounted grid tied PV system.  (50) modules with (2) 7.6 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57498	12041-10000-18485	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.30237	-118.46212	pLAN CHECK FOR FIRE ALARM SYSTEM. REPLACEMENT OF PANEL. ALL DEVICES ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57499	12041-20000-12970	7231 1/2 N RESEDA BLVD	91335	3	183B125    38	2118029018	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	PIN	34.20210477	-118.53644398	T-24 lighting plan check for CONVERTE EXISTING RETAIL TO TAKE OUT RESTAURANT AND TI (900SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57500	14041-20001-02949	19547 W SAN JOSE ST	91326	12	207B117   434	2708005021	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.26082	-118.55949	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57501	16041-10000-39567	5850 S VERMONT AVE	90044	9	105B197    72	6004001024	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	33.98773	-118.29129	PC FOR ENERGY AND POWER. . T.I CHANGE OF USE FROM  ONE RETAIL TO 4 RETAIL STORE. SCOPE INCLUDES NEW 2000 AMP 277/480 3 PHASE 4 WIRE  SERVICE/ DISTRIBUTION BOARD, NEW PANELS, AND CIRCUITS. TOTAL AREA 575 SQ FT.b# 16014-10000-05439	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57502	13041-10000-00794	7221 N VAN NUYS BLVD	91405	6	183B149    24	2218024015	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			01/11/2013 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.20192	-118.44901	replace existing fire alarm panel and 9 devices for restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57503	19041-10000-42429	401 E 7TH ST	90014	14	127-5A211 276	5148024026	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.04196	-118.24829	Plan check for a new fire alarm system. Scope includes (1) fire alarm panel, (5) power supplies, and (248) fire alarm devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57504	17041-20000-19194	865 S FIGUEROA ST 5th Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for energy only. TI to existing office on 5th floor of high rise building. New lighting (incl. emergency) - 1,893sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57505	12041-20000-13668	5979 W 3RD ST	90036	5	135B181    40	5512016017	C1-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.07002	-118.3508	T.I. to existing building partial of 2nd floor.  Install new lights in the coference and production rooms.  All other lights are existing.  Plan check for energy only.Note: Permit issued under 12041-90000-07191	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57506	19041-20002-02298	13115 N TELFAIR AVE	91342	7	222B141   327	2604002050	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.30778	-118.47865	Revision to approved set of plans.  Interconnection details changed - main service disconnect downrated to 500A.  (((PLAN CHECK FOR ROOF MOUNTED 166.5KVA PV2 SYSTEM CONSISTING OF 3 CENTRAL INVERTERS (5)SE33K-US WITH 500 MODULES USING P860 OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57507	15041-20000-16325	936 S OLIVE ST UNIT 246	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #20 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57508	18041-20001-35431	12710 W ADMIRAL AVE	90066	11	105B157   140	4223021020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			PC Approved	09/22/2018 12:00:00 AM	ADDRESS	33.98721	-118.42623	Expedited plan check fee.  PV1.  Install 7.250 kW DC roof mounted grid tied PV system with energy storage system.  (25) modules with 7.6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57509	13041-10000-04772	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.07417	-118.26931	NOTE: T24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER. PLAN CHECK FOR T24 IN EXISTING SPACE. TENANT IMPROVEMENT. EMERGENCY LIGHTS EXISTING AND NOT IN SCOPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57510	14041-10000-25693	12542 W FIELDING CIR	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	33.97819	-118.41198	PLAN CHECK FOR FIRE ALARM SYSTEM FOR APARTMENT COMPLEX WITH MULTIPLE BUILDING WITH MULTIPLE ADDRESSES. THIS IS BUILDING 3 OF 7. ALL BUILDING UNDER ONE SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57511	13041-10002-30569	1800 N ARGYLE AVE	90028	13	150A189   301	5546033015	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	06/09/2016 12:00:00 AM	ADDRESS	34.10384	-118.32506	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE NEW FIXTURE TYPES AND REVISION TO FLOOR PLAN. REVISED NUMBER OF ROOMS TO TOTAL OF 216 ROOMS. UPDATED PANEL SCHEDULES AND SINGLE LINE TO REFLECT CHANGES. ALL NOTED DELTA 4 AND 5 ON PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57512	16041-10000-13972	907 E 3RD ST	90012	14	129A215   276	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	PIN	34.04608986	-118.23489239	PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT WITH 400AMP FEEDER, FEEDING FROM A 1200AMP SWITCHBOARD. TOTAL AREA 3470 SQ FT.B# 15014-10000-05332	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57513	15041-10002-20170	6421 W SELMA AVE	90028	13	148-5A187 303	5546007023	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.09988	-118.33029	CHANGE TO APPROVED SET OF PLANS. UPDATE ELECTRIC ROOM. PC ONLY. PERMIT ALREADY UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57514	16041-10000-01446	633 W 5TH ST 44TH FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57515	19041-20000-00046	5670 W WILSHIRE BLVD 100	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for Title 24 only in existing space Interrior Remodel Total area: 7789 sq ft. B-18016-10000-41259	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57516	17041-20000-02303	5302 N CLEON AVE	91601	2	171B173   296	2416007009	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			01/24/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.16718	-118.36845	Plan check for power and energy. Project site is a new 2-story, 7-unit apartment building. Work includes an 800-amp service and a total lighting area of 6,362 sq. ft.Note: Building application has been generated under 16010-20000-05289	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57517	14041-10000-08166	939 S HILL ST	90015	14	127-5A209 229	5139004008	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			04/01/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.04215	-118.25823	NEW FIRE ALARM SYSTEM FOR MIXED USE AND 281 UNIT APARTMENT BUILDING. BUILDING PERMIT #: 12010-10000-02348	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57518	14041-20001-09881	20138 W ELKWOOD ST	91306	3	189B113  1043	2107022050	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.21222	-118.57234	PV1.  Install 12.25 kW roof-mounted PV system, interconnect with existing main service panel.  Transformerless inverter: SolarEdge SE6000A w/ power optimizers.  (49) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57519	13041-20000-25482	8900 N DE SOTO AVE Grit Blast	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	ADDRESS	34.23162	-118.58832	T24 FOR GRIT BLAST ROOM. ADDING NEW LIGHTS AND EQUIPEMENT. NEW CONNECTED LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57520	10041-20000-09305	731 W 32ND ST	90007	8	120A201    24	5123011011	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	06/21/2010 12:00:00 AM	ADDRESS	34.02478	-118.2815	FIRE ALARM SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57521	16041-10000-26099	23340 W AVENUE SAN LUIS	91364	3	168B093   227	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.15957	-118.63536	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1356 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57522	16041-20000-43274	5611 N FIGUEROA ST #4	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.10937	-118.19392	TI TO (E) RETAIL SPACE AND CONVERT TO GROCERY STORE WITH ACCESSORY KITCHEN IN BACK.  PLAN CHECK FOR ENERGY.  Building permit filed under 16016-10000-26331.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57523	19041-10000-03403	304 S BROADWAY #330	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.05076	-118.248	TI IN AN EXISTING LOW-RISE OFFICE BULDING IN SUITE#330.  T-24 ENERGY ONLY. BULDING PERMIT: 18016-10000-39002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57524	14041-20001-11639	11358 W SHELDON ST	91352	7	201B173   124	2538023005	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.25037	-118.37842	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 8kW(2) SMA American SB4000TL-US-22 transformerless inverter(33) ET Solar ET-P660250BB pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57525	15041-20000-31697	21013 W SHERMAN WAY	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			PC Approved	11/20/2015 12:00:00 AM	ADDRESS	34.20125	-118.5914	"PLANCHECK FOR T24 ENERGY. CHANGE OF USE RETAIL TO RESTAURANT. ""RASPADOS Y CHURROS FRUTAL INC "" 1760 SQFT.***2/23/16: changed of tenant, NEW PC under 16041-10000-06296 ""CORN N' CRAB"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57526	15041-10000-06485	722 N VAN NESS AVE	90038	13	141B189   230	5535002004	R3-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Closed	12/05/2017 12:00:00 AM	ADDRESS	34.08418	-118.31559	PV2, INSTALL NEW 16.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING. (60) MODULES; (3) INVERTERS: DELTA -SOLIVIA 5.2TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57527	10041-20001-19694	9355 N REMICK AVE	91331	6	198B161   275	2629027023	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.23892	-118.41323	PLAN CHECK T24 PLAN CHECK GENERAL/EMERGENCY LIGHTING FOR SHOW ROOM TI. ADDITIONAL PERMIT FOR CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57528	12041-10000-20728	4886 N WINNETKA AVE	91364	3	168B113    91	2175019009	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.15965	-118.56961	Photovoltaic system. roof mounted, 9.2 KW, 28 modules.  Note: Permit includes the new 225A main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57529	10041-10001-13764	3455 S OVERLAND AVE	90034	5	120B161   672	4254026006	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM			PC Approved	01/19/2011 12:00:00 AM	ADDRESS	34.02511	-118.41213	Change the priviously aproved plan. Change the lighting & T24 calc. EPC is for T24. (((((((((((((EPC title 24 and emergency lighting one story restuarant.))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57530	19041-10000-50875	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM			Permit Finaled	06/16/2022 12:00:00 AM	ADDRESS	33.94558	-118.4039	Full plan check for LAX Terminal 2 Renovation. Scope include new lighting and equipment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57531	12041-10000-13686	8401 N VAN NUYS BLVD #25	91402	7	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.22308	-118.44896	TENANT IMPROVEMENT FOR RETAIL STORE, 31' X 151'.  NON-BEARING PARTITION WALLS, NON-STRUCTURAL, SUSPENDED CEILING, NEW FITTING ROOMS AND HC RESTROOM.plan chk is for title 24  (PERMIT FEES ARE UNDER INSPECTION.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57532	14041-10000-10252	11410 W DONA LOLA DR	91604	2	159B173   406	2380017016	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.13223	-118.37929	$0 permit fee is issued per senate 1222.PV1 FOR ROOFMOUNTED SYSTEM. TOTAL SYSTEM SIZE 11KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57533	14041-20000-29087	444 S FLOWER ST 2ND FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	TI TO AN EXISTING HIGHRISE COMMERCIAL BUILDING.  ADDING LIGHT FIXTURES TO RESTROOM IN THE SECOND FLOOR. 420SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57534	17041-20000-03710	700 S FLOWER ST Ste 2625	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to (E) commercial office space.   Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57535	18041-10000-20324	7843 N LANKERSHIM BLVD Suite #200	91605	6	189B169   517	2310025034	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	FIRST TIME OCCUPANCY OF A NEW OFFICE SPACE ON 2ND FLOOR.FULL PLAN CHECK FOR POWER AND ENERGY.BULDING PERMIT # 16016-10000-30375	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57536	18041-20000-32862	4327 W ADAMS BLVD	90018	10	123B185   658	5059005001	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.02	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.03275	-118.33285	Renovation of (E) restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57537	10041-10000-08808	540 W PATRICE PL	90248	15	063B201   194	7339008023	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	08/25/2010 12:00:00 AM	ADDRESS	33.86597	-118.28322	TI IN AN AN EXISTING WAREHOUSE. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS. PERMIT IS FOR NEW CONDENSING UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57538	16041-10000-29367	11646 W PENDLETON ST	91352	6	195B169   448	2631018084	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.22864	-118.38644	PC FOR POWER ONLY. SCOPE INCLUDES A NEW 800A 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, AND TWO NEW PANELS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57539	17041-10000-12268	515 S FIGUEROA ST STE 1400	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Approved	04/14/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	PC for T24 only for lights and receptacles for TI project in office in high rise. Total area is 9771 sqft. Load is under 400A. Building #17016-10000-07550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57540	10041-10011-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Addition and alteration to the TBIT.  The Core Design Notices in which each sheet  changes are noted. Changes include installation of unit equipment, J-boxes for wiring to security access doors,exterior wal luminaires, and circuits for GFCI receptacles in janitors' closets. Include CDN-0261,-0301, and -0285; RFI-0342,-285, and-0281.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57541	10041-10000-21089	1300 E FACTORY PL	90013	14	126A215   235	5164008031	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM	12/10/2010 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.03904	-118.23584	This is a 4 stories commercial bldg. New Fire Alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57542	12041-10000-02110	11333 N SEPULVEDA BLVD	91345	7	213B145   166	2664001801	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1092.00	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.27646	-118.46863	1st time tenant, new restaurant on the first floor of a new medical office building.  (((Approved building plans are attached as reference)))  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57543	12041-10000-19537	5811 S SAN PEDRO ST	90011	9	108B205  1113	5101021001	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	33.98946	-118.2703	REMODEL SMALL AREA IN EXISTING OFFICES-NEW LUMINAIRES AND RECEPTACLESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57544	14041-10001-17500	2049 S CENTURY PARK EAST SUITE 2500	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM			PC Approved	04/02/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	SUPLEMENTAL ON LOST APPROVED SET OF PLANS , SUIT # 2500.NO CHANGE IN THE SCOPE OF WORK, ONLY T24. PERMIT TO BE PULLED UNDER MASTER APPLICATION.<<<TITLE 24 FOR HIGH RISE OFFICE BUILDING.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57545	14041-20000-01404	1907 W BELLEVUE AVE	90026	13	138A207   187	5404011017	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Expired	02/10/2016 12:00:00 AM	ADDRESS	34.07227	-118.26465	New roof mounted PV system for an existing single family dwelling.  System is UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57546	11041-20000-25549	11126 W CHANDLER BLVD	91601	2	171B173   166	2350015043	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM			PC Approved	11/30/2011 12:00:00 AM	ADDRESS	34.168	-118.37334	Commercial installation of a roof mounted PV system.  Plans were originally plan checked and aproved under 11041-20000-03913 but the approved set of plans were lost.  A permit has already been pulled for this project.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57547	17041-20000-18521	321 N LARCHMONT BLVD STE 1023	90004	4	138B189   360	5523020038	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM			PC Info Complete	06/02/2017 12:00:00 AM	ADDRESS	34.07682	-118.32384	TI TO SUITE 1023 - PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57548	09041-20001-24366	3327 E SABINA ST Bldg A	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			06/29/2011 12:00:00 AM			PC Approved	07/12/2011 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 4 Revision to approved plans. Change from CU feeders to AL feeders for New Apartment Complex w/ multiple buildings (Bldg A) 1of 2 Building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57549	11041-10000-01955	4734 W FOUNTAIN AVE	90029	13	147B197  1140	5540018012	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM			PC Info Complete	05/09/2011 12:00:00 AM	ADDRESS	34.09527	-118.29296	NEW LAUNDRY FACILITY.  ELECTRICAL PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57550	18041-30000-37876	10866 W WILSHIRE BLVD #870	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM			PC Approved	10/04/2018 12:00:00 AM	ADDRESS	34.05907	-118.442	PC FOR TI-24  ENERGY ONLY FOR OFFICE TI IN A HIGH RISE.  SCOPE INCLUDES NEW LIGHTS ONLY.TOTAL AFFECTED AREA  2186 SQ.FT THIS IS PLAN CHECK ONLY.  B#18016-10000-27591PERMIT UNDER 18041-10000-34292	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57551	16041-10000-41420	3636 N BARHAM BLVD BLDG S	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.13868	-118.34148	PC FOR NEW PANELS, STACKED WASHERS & DRYERS IN CERTAIN APT. UNITS, NEW ELECTRICAL DRYER VENTS. INSTALLATIONS IN BUILDING S OF CAMPUS STYLE COMPLEX. THIS IS BUILDING 4/6. (Add 1 laundry ckt to 24 units, and 1 microwave ckt to all 36 units in the building, total 60 new ckt in the building.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57552	11041-20000-17660	10118 N SAN FERNANDO ROAD #1	91331	7	204B161   473	2537010002	[Q]CM-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	ADDRESS	34.25423	-118.40867	Subway1st time tenent in new bldg.Shell 10041-20000-20455	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57553	17041-20000-44226	2106 S NARCISUS CT	90291	11	108B145  1834	4237003030	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	01/14/2021 12:00:00 AM	ADDRESS	33.98883	-118.45995	Full PC for Power and Energy for a New 2-story manufacturing building.  Scope includes a new 600A Service/distribution board, new panels, and circuits. Total affected area is 6793 Sq. Ft. B#17010-20000-04835.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57554	11041-10000-00009	2536 W TEMPLE ST	90026	13	138A203   320	5157002026	(Q)P-1	Central	Westlake	Greater Echo Park Elysian	YES	2086.20	Electrical	Electrical	Commercial			01/03/2011 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	34.07191	-118.2747	Ti for a medical office building. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57555	15041-10000-37982	5700 N CANOGA AVE 2ND FLR	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM			Corrections Issued	11/10/2015 12:00:00 AM	ADDRESS	34.17365	-118.59715	T-24, TI IN AN OFFICE BUILDING, SCOPE OF WORK INCLUDES NEW FIXTURES TO BE DIMMABLE IN A PORTION OF AN OPEN OFFICE. TOTAL SQ. FT. BEING WORKED ON 2920.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57556	15041-20000-29131	6171 N SEPULVEDA BLVD	91411	6	177B145   355	2242001015	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			Reviewed by Supervisor	10/02/2015 12:00:00 AM	ADDRESS	34.18246	-118.46651	Plan check for power and lighting. Project scope is a new 1-story commercial building. Work includes a new 1200-amp service, and (1) house panel. Total outdoor lighting area = 10,240 sq. ft. Core and shell.Note: Building permit filed under application number 15010-10000-03148	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57557	13041-10001-26701	8500 W BEVERLY BLVD UNIT 695	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGES TO APPROVED SET OF PLANS  # 13041-10000-26701.  DELTA 5 CHANGES ONLY. CHANGING F8 LUMINAIRE AND CIRCUIT CHANGES. REPLACING 30 SPACE PANEL WITH 42 SPACE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57558	14041-10000-17814	3550 W WILSHIRE BLVD	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.06157	-118.30226	Fire alarm panel replacement and common area HIV upgrade for 21 story building.. Riser (e) to remain. One-for-one replacement of initiating devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57559	17041-10000-13659	20151 W NORDHOFF ST	91311	12	195B113    68	2781035035	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.232	-118.57341	OFFICE TI WITH SOME EXAMINATION ROOMS. THIS IS OFFICE SPACE, NEW POWER AND LIGHTING. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57560	14041-20001-04832	1309 N LA BREA AVE	90046	4	144B181   105	5548022097	[Q]C2-2D-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM			PC Approved	12/30/2015 12:00:00 AM	PIN	34.09463172	-118.34444205	changes to approved set of plans. changes include new lighting fixture, new ceiling layout. updated title 24 forms and lighting plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57561	12041-10000-25337	3607 W SUNSET BLVD	90026	13	144A203    58	5429022002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.09019	-118.2769	This is a full plancheck for a change of use from a hair solan to a market, mew sevice, panels, ckts and title 24, one story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57562	11041-10000-22362	8600 S CENTRAL AVE	90002	9	097-5A209 255	6043001027	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	33.95988	-118.25616	New single-story commercial building, Core and Shell.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57563	15041-20000-14782	16000 W VENTURA BLVD Ste 900	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.15584	-118.48164	Plan check for Title 24 only. Project site is a suite on the 9th floor of a high rise building. Total lighting area = 259 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57564	17041-20001-39735	5245 N VINELAND AVE 1st floor-#5	91601	2	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.16636	-118.37064	Plan check for energy only per inspector correction notice for change of use. this is plan check only.  no new circuits. (((INSTALL CIRCUITS FOR NEW OUTLETS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57565	14041-10000-03033	3426 S COCHRAN AVE	90016	10	120B177   859	5047010007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Expired	03/30/2016 12:00:00 AM	ADDRESS	34.02434	-118.3613	PV1. ROOFMOUNTED SOLAR SYSTEM. INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 3KW.TRANSFORMERLESS UNGROUNDED SYSTEM.(12) TRINA SOLAR # TSM-250(12) SOLAREDGE POWER OPTOMIZERS OP300(1) SOLAREDGE # SE3000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57566	16041-10000-08826	13409 W TRUESDALE ST	91402	6	192B157   543	2637014020	(T)R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Expired	04/13/2018 12:00:00 AM	ADDRESS	34.22251	-118.42426	PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 46 MODULES IN TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57567	16041-10000-23637	189 S THE GROVE DR H20	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	Plan check per customer request in regard to an existing Methane detecting system with one sensor and the the control panels being relocated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57568	13041-10000-07087	20337 AVENIDA ALEGRE	91326	12	210B113   222	2701075157	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			03/19/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	PIN	34.27551645	-118.57692108	INSTALLATION OF NEW LIGHTS FOR OUTDOOR USE. LIGHTING FOR GENERAL HARDSCAPE LIGHTING. TOTAL AREA 165,345 SQ FT.PLAN CHK IS FOR TITLE 24 ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57569	16041-10002-45423	2268 W VENICE BLVD	90006	10	126B193   316	5074014048	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.04337	-118.30833	TI FOR COFFEE SHOP. PC FOR T24 ENERGY ONLY. PC ONLY. PERMIT ALREADY COVERED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57570	19041-10000-32278	16717 S FIGUEROA ST	90248	15	066B201    50	6121004039	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.87973	-118.2827	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57571	15041-20000-10155	19333 W BUSINESS CENTER DR	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.23134	-118.55494	Power plan check for a new dialysis clinic. Project scope is a new 800-amp service, and includes the installation of (1) 800-amp MSB, (4) 200-amp panels, (1) 225-amp, and associates loads. I-2.1 occupancy areas exempt from Title-24, rest of building is not. Project is OSHPD-3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57572	18041-30000-33734	9006 W THRASHER AVE	90069	4	147B169   733	5560004010	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM			PC Approved	11/16/2018 12:00:00 AM	ADDRESS	34.09761	-118.38638	Plan check for Power only on a new one story single family dwelling with basement and attached garage. New 800A, 120/240V, 1ph service, (10) new panelboards, (1) 30 kW Generator, (1) 10 kVA steam generator, (2) elevators, and (2) EVCS **This is plan check only, permit is covered under Building Combo Permit # 16010-30000-04367**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57573	14041-10000-10682	1000 S HOPE ST	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.04346	-118.2617	MIXED USE/RETAIL. TI to SHELL LEASE SPACE: ADDITION OF LTG IN HIGH RISE to show off space only. Exit signs to have dual inputs (EM-2 per engineer). BLDG#13016-10-09530.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57574	14041-10001-26721	7454 1/2 W BEVERLY BLVD	90036	5	138B181   471	5512008001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM			PC Approved	12/15/2014 12:00:00 AM	ADDRESS	34.07596	-118.35248	Delta-1 revisions.  Change of lighting fixtures.  (((Title 24 energy plan check.  Code based on 2008 and no change in occupancy. Newly connected load < 400 amps, indoor.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57575	19041-10000-52973	12580 W SATICOY ST BLDG C-2ND FLOOR	91605	2	186B161   405	2305025022	M1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.2075	-118.40783	REMOVE 2ND FLOOR INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57576	12041-10000-05987	8550 N BALBOA BLVD SUITE 195B	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	ADDRESS	34.22649	-118.5024	TI IMPROVEMENT OF OFFICE. PLAN CHECK AT COUNTER FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57577	11041-20000-12524	3601 S WATT WAY 2ND & 3RD-FLR	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	ADDRESS	34.02113	-118.28752	Plan check T24 Energy compliance for alteration to existing lighting. Relocate light fixtures and mandatory measure switching.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57578	16041-20000-15967	6420 W WILSHIRE BLVD 4th FL	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	05/06/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check Title 24 only T.I. in existing building. Total area: 2,856 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57579	14041-10000-35959	730 S LOS ANGELES ST	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM			PC Info Complete	06/04/2015 12:00:00 AM	ADDRESS	34.04254	-118.25109	HIGH RISE new fire alarm system with (1) fire alarm control panel, 7 power supplies and 361 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57580	17041-10000-04608	20201 W RINALDI ST BLDG A2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	34.27512	-118.57373	PC FOR POWER AND ENERGY. NEW BUILDING A2   -SHELL ONLY  COMMERCIAL BLDG - 1 STORY   SERVICE SIZE 800 A, 277/480 V, TOTAL AREA 2805 SQ FT.BUILDING APP 16010-10000-06135, BUILDING 2 OUT OF 13 BUILDINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57581	17041-20000-28893	9900 N BALBOA BLVD	91325	12	201B133   127	2685009020	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	ADDRESS	34.25067	-118.50215	Plan check for power and energy. New commercial retail building (Starbucks w/drive-thru). 600A 120/208V 3ph 4w service. T24 area: indoor-2,045sqft; outdoor-20,000sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57582	13041-20000-23728	17830 W TUSCAN DR	91344	12	222B129   367	2601056005	A1-1-K, A1-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Expired	10/13/2015 12:00:00 AM	ADDRESS	34.30121	-118.52321	pv1 single family dwelling. tota system size 6 kw ac using 25 modules. transformerless inverter nonstandard plan. using 2 strings/inverter.  PLAN CHECK/PERMIT IS FOR PV SYSTEM ONLY, NOT FOR RELOCATING CIRCUITS, NEW PANELS, OR DERATING MAIN BREAKERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57583	16041-20001-07385	1757 N BEL-AIR ROAD	90077	5	147B149   108	4370014023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.102	-118.44823	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (37) AC modules and (1) load center. PV system is interconnecting with a 400-amp split-bus MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57584	14041-10000-33632	10700 W SANTA MONICA BLVD 301	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.05167	-118.432	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A DENTAL OFFICE. TOTAL AREA 1730 SQ FT. PLAN CHECKER TO VERIFY THE FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57585	17041-10000-45922			15	030B205   397	7423002012	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			Reviewed by Supervisor	01/19/2018 12:00:00 AM	PIN	33.77978611	-118.26137665	PC FOR ROOF MOUNTED PV ON COMM. BUILDING WITH LINE SIDE CONNECTIONSYSTEM SIZE 43.2KWDC 34.2KWAC. SCOPE INCLUDES 144  PANELS WITH OPTIMIZERS. 3 SOLAREDGE INVERTERS 11400 A-US.  AND NEW 250A LOAD CENTER. B# 17016-10000-37947	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57586	15041-20000-28016	230 S SANTA FE AVE SPACE N	90012	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			Corrections Issued	08/26/2015 12:00:00 AM	ADDRESS	34.04661	-118.2324	PLANCHECK FOR POWER ONLY. INSTALLTION OF 2 PANELS AND A TRANSFORMER FOR FUTURE TENANT BUILD OUT. SPACE N	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57587	16041-10000-29497	10201 W PICO BLVD BLDG 307	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	09/17/2016 12:00:00 AM	ADDRESS	34.04994	-118.41129	New Fire alarm for an existing building.Total of 12  new devices and 1 control panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57588	13041-20000-06037	14139 W GILMORE ST	91401	6	180B153   892	2237018020	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.00	Electrical	Electrical	Apartment			03/07/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.18776	-118.44137	Plan check for fire alarm system. Existing apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57589	13041-10001-06035	1331 N WATERLOO ST	90026	13	141A207   127	5424023005	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.08135	-118.26535	MODIFICATION TO APPROVED SET OF PLANS. CHANGE OF MODULET TYPE FROM TRINA SOLAR # TSM --240PA05 TO TRINA SOLAR # TSM-245PC05.***********************************************************************PHOTOVOLTAIC SYSTEM FOR MULTIFAMIYL DWELLING. TOTAL SYSTEM SIZE 1.68 KW. THIS APPLICATION IS PART OF A SERIES OF 3. DUE TO THE COMPLEX NATURE OF THE METERING SECTION, BACK ROOM WAS RECOMMENDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57590	10041-20001-17057	825 E 4TH ST 1-53	90013		127-5A215 174	5163011028	M3-1		Central City North	Historic Cultural			Electrical	Electrical	Apartment			09/02/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	34.0435	-118.23728	revise electrical room split two 800 amps swbds to fit in electrical room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57591	14041-10000-14728	15963 W STRATHERN ST	91406	6	189B141    23	2206005021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.21581	-118.48145	Power and energy plan check for change of use from open warehouse to production office and utility space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57592	12041-10004-30779	"12746 W JEFFERSON BLVD ""4"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM			PC Approved	05/05/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	SUPPLEMENTAL RO AN APPROVE SET, APPLICANT PROVIDED SHORT CIRCUIT CALCULATIONS ON DISTRIBUTION BOARD 'DL4'.  'DELTA E'(((Plan check power and energy for Building 4. Five story parking garage building with common subterranean parking to Building 1, 2, 3, and 4. Service supply from Building 3. Site located in methane zone. Modification to separate fire alarm system has been filed))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57593	14041-10001-32210	117 S BOYLE AVE	90033	14	129A221   232	5174013905	C2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.04687	-118.22011	REVISIONS TO PERMITTED SET OF PLANS: REPLACING AN ELEVATOR WITH A PUMP MOTOR OF THE SAME HP RATING; ADDING 1/2 HP JOCKEY PUMP((((((((((((Full plan check for new appartment(4 stories) with partial first floor commercial(core and shell for commercial first floor).  Service size 2,500 Amps. Note: Variance to seperate fire alarm has been filed (11/19/2014)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57594	18041-10001-46439	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	06/08/2022 12:00:00 AM	ADDRESS	33.94502	-118.40714	LAX Terminal 3 Renovation (Phase I). Concourse and Head House.Building Permit: 18016-10000-19512	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57595	16041-20000-40575	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.18686	-118.37207	TI to (E) Target retail store.  Additional display lighting for liquor aisles.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57596	17041-20000-44441	9376 W READCREST DR	90210	4	147B165   564	4352012019	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.09564	-118.40394	Plan check for solar pv system w/roof-mounted array on SFD.7.6kW ungrounded system. (29) 360W pv modules. (29) 370W power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57597	14041-10000-13100	4214 S LINCOLN BLVD	90292	11	105B153    50	4230001010	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	33.98678	-118.44402	Plan check for power and energy. FIRST TIME TENANT (Bevmo).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57598	17041-10000-37840	6157 N RHODES AVE	91606	2	177B165   338	2333011020	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.18272	-118.40315	PLAN CHECK FOR ROOF MOUNTED PV ON SINGLE FAMILY. SYSTEM SIZE 10.4KWAC/12.0KWDCSCOPE INCLUDES 40 MODULES WITH MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57599	17041-10000-23746	6201 N VINELAND AVE	91606	2	177B173   365	2336021009	PF-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.18337	-118.37062	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 23400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57600	19041-20000-47213	18050 W VANOWEN ST	91335	3	180B125    48	2122028013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/09/2021 12:00:00 AM	ADDRESS	34.19372	-118.52686	Plan check for Title 24 energy only add new lights, total area: 2050 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57601	18041-10000-05730	1360 S FIGUEROA ST	90015	14	126A205    86	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.03896	-118.26891	"PC FOR POWER ONLY. SCOPE INCLUDES INSTALLING TWO FEEDER TAPS  TO DISTRIBUTION BOARD ""MS1C"" WITH FUSED DISCONNECTS, AND INSTALLING FIVE NEW PANELBOARDS.  NOTE: SOME PERMIT FEES WERE PAID UNDER ORIGINAL PERMIT PCIS#17041-10000-39737"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57602	12041-20000-08358	318 S LA BREA AVE	90036	4	135B181   238	5507008023	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.06827	-118.34383	TI for existing ice cream shop. Single story commercial building. Plan check for energy and emergency lighting. 1000 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57603	12041-10000-27953	6087 W SUNSET BLVD	90028	13	147A189    49	5545008002	[Q]C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.09819	-118.32178	PLAN CHECK FOR FIRE ALARM WITH 11 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57604	19041-20000-47925	22940 W DOLOROSA ST	91367	3	174B097   816	2042008093	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.16994	-118.6269	PV1.  Install 10.89 kW roof mounted grid tied PV system.  (33) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57605	13041-20000-07905	1863 W BLAKE AVE	90039	13	147A213    71	5442008034	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.0983	-118.24347	Existing low-rise Commercial Workspace for Artist.  New 400 amp service, new lighting, new loads/circuits.  Permit fees are under Inspection.  INVESTIGATION FEES HAVE BEEN ADDED TO THE PERMIT TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57606	11041-20000-25231	1220 N HIGHLAND AVE 1ST FL.	90038	4	144B185   341	5532005038	C2-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.09323	-118.33841	"new lighting for bathroom & hallwayEnergy & emergency""COMPLY WITH DEPARTMENT ORDER effective date 08.11.2011.  PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57607	15041-20000-25334	5771 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Info Complete	11/24/2015 12:00:00 AM	ADDRESS	33.94955	-118.38342	Plan check for power and Title-24 (energy).  Total area = 27,000 sq. ft.  Construct new 2 story addition to existing building to contain a loading dock, warhouse, maintenance shop, and supporting offices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57608	18041-10000-16844	11439 N ENCINO AVE	91344	12	213B129   333	2711022027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.27848	-118.51547	PC for T-24 only. Removal of  HID and replacment with new LED fixtures	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57609	17041-20000-28121	12249 N LIMA WAY	91342	7	219B149   929	2611046021		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.294	-118.45558	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57610	15041-10000-21823	1808 S CARMONA AVE UNIT 2	90019	10	126B177   903	5064010010	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.04106	-118.36071	PV2, ROOF MOUNTED SOLAR, 2.6 KW PV ARRAY.(1)INVERTER: PVI-3.0-OUTD-S-US-Z-A(10)MODULES: KU2606XPA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57611	19041-10000-05126	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.21302	-118.45859	PLAN CHECK FOR POWER ONLY FOR EV CHARGING STATIONS AND NEW SERVICE RATED AT 1600A - EQUIPMENT CONSIST OF (3) 150KVA-240FLA CHARGERS AND 1 LEVEL 2 CHARGER WITH POWER UNITS CONNECTED TO A NEW 1600A 480/277V SYSTEM. B#19016-10000-04073	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57612	16041-20000-15848	5840 N ETIWANDA AVE NO 4	91356	3	174B125    32	2157012***	(Q)RD3-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.1772	-118.53064	Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a COMMERCIAL BUILDING.THIS IS PLAN CHECK ONLY.  PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-90000-13577	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57613	15041-10000-42776	10410 N SEPULVEDA BLVD	91345	7	204B145    69	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.25968	-118.46706	Full Plan check for an existing  building being remodeled.  Service upgrade to 1200. Panel LA and LB loads to be featured. Total sqft = 7258.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57614	16041-20000-35240	8436 W 3RD ST 602	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.07301	-118.37448	ti to an existing commercial office building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 948.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57615	19041-10000-18375	13620 W SUNSET BLVD	90272	11	129B133    86	4408001008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.05241	-118.50314	$0 Fee per AB1414. [E-PLAN] PV1. PLAN CHECK FOR A ROOF MOUNTED 21.46KWac PV SYSTEM CONSISTING OF 58 AC MODULES(SPR-X22-370-D-AC) CONNECTED TO EXISTING 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57616	15041-10002-08748	462 E COMMERCIAL ST	90012	14	130-5A215  46	5173001905	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.05309	-118.23584	CHANGES TO AN APPROVED SET OF PLANS - PLAN CHECK FOR POWER ONLY(DELTA 5 AND 6 CHANGES).SCOPE OF WORK INCLUDES UPGRADE OF MAIN SERVICE FROM 4000A TO 6000A, RELOCATION OF MAIN SWITHCBOADS, AND RELOCATION OF EXISTING LOADS. SCOPE ALSO INCLUDES ADDITION TO EV BUS CHARGING STATION(6 TO 28) WITH NEW CONDUIT AND BREAKERS(NO EQUIPMENT).SERVISE LOAD CALCULATIONS HAVE ALSO CHANGED ORIGINAL PERMIT (15041-10000-08748 & SUPPLEMENTAL TO LOST SET 15041-10001)  PC only due to lost approved set.This is 1 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************PC FOR POWER AND ENERGY. NEW 3000 A SERVICE FOR LOS ANGELES DEPT OF TRANSPORTATION FACILITIES CONSISTANT OF MAINTENANCE AND OPERATION BLD, PARKING STRUCTURE, TANK FORM BLDG AND SERVICE BLDG.(MAINTANANCE INCLUDES CLASS ONE DEVISION 2 AREA). TOTAL AREA (INDOOR 36875)  + (67828 OUTDOOR) 104703 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57617	15041-10000-25797	7440 N FULTON AVE	91605	2	186B157   282	2327001005	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.20582	-118.42241	PC FOR ENERGY ONLY, T-24 TO A FIRE DAMAGE BLDG. SCOPE OF WORK INCLUDES INSIDE RENOVATIONS TO THE BLDG. TOTAL SQ FT  = 5151	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57618	17041-20001-01430	2694 W JAMES M. WOOD BLVD	90006	1	132A201   210	5077028002	R4-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.05575	-118.28671	expedite per applicantpv2install roof mounted pv system sized 6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57619	13041-10001-34279	21720 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/09/2014 12:00:00 AM			Corrections Issued 2	07/09/2014 12:00:00 AM	ADDRESS	34.18733	-118.60234	REVISED PERMITTED SETS OF PLANS TO INCUDE CONDUITS ONLY FOR  LOW VOLTAGE/ COMMUNICATION WIRING PLAN REVIEW FOR THE 35KV SERVICE AND ASSOCIATED DISTRIBUTION SYSTEM TO SUPPLY A NUMBER OF BUILDINGS TO BE CONSTRUCTED AS PART OF A NEW MALL.PLAN CHK WILL BE FOR THE 35KV LANDINGS TO THE OUTSIDE PERIMETER OF EACH BUILDING FOOTPRINT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57620	11041-10000-22762	5150 W WILSHIRE BLVD 2nd floor	90036	4	132B181    35	5507025021	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM			PC Approved	10/24/2011 12:00:00 AM	ADDRESS	34.06202	-118.3421	T.I. to an existing office building on the 2nd floor.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57621	14041-10000-14926	5324 S 9TH AVE	90043	8	108B185   216	5006018020	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	33.99417	-118.32677	PV1, INSTALL 3.315 KW DC ROOF-MOUNTED SOLAR ARRAY ON ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57622	14041-10000-35904	8563 N SAN FERNANDO ROAD	91352	6	192B173   199	2632007003	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.22491	-118.3779	PLAN CHECK FOR ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57623	19041-20001-50382	4575 W DUNDEE DR	90027	4	153B197    43	5588033022	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM			PC Approved	12/14/2019 12:00:00 AM	ADDRESS	34.1172	-118.28756	PV1 PLAN CHECK FOR NEW ROOF PV AND ESS. SYSTEM SIZE IS 16.17 KW DC/14.89 KW AC CEC. ESS SIZE IS 13.5 KWH. SCOPE OF WORK CONSISTS OF (49) PV MODULES WITH MICROINVERTERS, (2) SUB PANELS, AND (1) 13.5 KWH BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57624	14041-10000-11979	3370 S LIVONIA AVE	90034	5	123B169  1520	4312013031	M1-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2701.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.02921	-118.39258	Remove HID light fixtures and replace with new flourescent fixture	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57625	18041-20000-38952	4316 N LANAI ROAD PV3	91436	5	165B137   222	2284012028	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM	01/17/2019 12:00:00 AM		Issued	01/17/2019 12:00:00 AM	ADDRESS	34.14892	-118.49181	permit fees $0.00 by senate senate bill no.1222Plan check for PV roof mounted system on commercial building, System size: 199.75KW DC, 172KW AC with 655 modules and 4 inverters(43.2KW) Supply side connection to Exist 1600A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57626	15041-10000-04820	546 N OXFORD AVE	90004	13	141B193   978	5521013026	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			02/18/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.08121	-118.30785	Plan check for a fire alarm system. Project site is an existing building. Fire alarm consists of (1) FACP and (84) devices. Building is not a high-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57627	16041-10000-42204	834 W 30TH ST	90731	15	009B197  1349	7469010009	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	33.71751	-118.29644	PV2 roof mounted solar system installation. Intalling a 3.0 KW central inverter with 8 solar modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57628	19041-10000-13828	800 N CHESTNUT AVE	90042	14	154-5A235 617	5493037016	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Apartment			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.1176	-118.17112	PV2. NEW ROOFTOP SOLAR SYSTEM IN AN APPARTMENT COMPLEX. CONSISTS OF 12 MODULES ( SUNPOWER AC 370). SYSTEM SIZE IS 4.44KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57629	19041-30000-53402	1127 W WILSHIRE BLVD SUITE#1618	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Issued	01/28/2020 12:00:00 AM	ADDRESS	34.05287	-118.26415	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFCTED AREA IS 4356 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57630	16041-20000-25552	10130 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.25424	-118.57964	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR A NEW HEALTH CLUB. FITNESS 19.Note: Building application has been generated under 16016-20000-16773	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57631	16041-10001-22361	4350 N LAUREL CANYON BLVD	91604	2	165B165   455	2368013052	[Q]C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	34.14989	-118.39625	PC FOR POWER AND ENERGY PER INSPECTOR REQUEST. CHANGE OF USE TO RESTAURANT. NEW KITCHEN EQUIPMENT AND OTHER RELATED LOADS. THIS APPLICATION IS PLAN CHECK ONLY. PERMIT ALREADY ISSUED UNDER MASTER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57632	19041-10000-21730	627 S SAN JULIAN ST	90014	14	127-5A213 434	5148024018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.04231	-118.24675	PLANCHECK FOR A NEW FIRE ALARM IN A MIXED USE COMMERCIAL BUILDING. SCOPE INCLUDES NEW FA CONTROL PANEL, COMMUNICATOR PANEL, AND 50 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57633	15041-10000-42637	512 E ROSE AVE	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/17/2016 12:00:00 AM	ADDRESS	33.99813	-118.47363	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR RESTURANT. TOTAL AREA 2278 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57634	10041-20000-12370	8229 W FOOTHILL BLVD	91040	2	204B193   135	2555022004	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			06/29/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	11/18/2010 12:00:00 AM	ADDRESS	34.25984	-118.31235	Installing a 200 amp subpanel to be used for new tenant and two ac units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57635	19041-20000-47644	4820 N SAN FELICIANO DR	91364	3	168B101   705	2170016026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.15509	-118.60971	PV1.  Install 12.24 kW roof mounted grid tied PV system.  (34) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57636	12041-10000-06204	700 W WORLD WAY 7H	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM			PC Approved	03/19/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	EMERGENCY LIGHTING AND ENERGY TITLE 24 ONLY.  LAX, TERMINAL 7.  2ND FLOOR.  RETAIL SPACE, 1356SQFT.  SUITE 7H. HARLEY DAVIDSON STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57637	17041-20000-10033	11212 S CONTINENTAL CITY DR	90045	11	087B173    97	4129037911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Closed	03/04/2019 12:00:00 AM	ADDRESS	33.93252	-118.37629	PORTABLE ROCK CRUSHING PLANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57638	12041-20000-12839	4151 W PROSPECT AVE 1st floor	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Greater Griffith Park	YES	1952.00	Electrical	Electrical	Commercial			06/04/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.10191	-118.28217	T.I. to server room.  New electrical load exceed 400A.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57639	18041-10000-48227	110 W 11TH ST #200	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.0392	-118.25858	Energy plan check for an office T.I located on the second floor of  a commercial building; Scope includes new lighting and equipment with a total area of 6227-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57640	15041-10000-02902	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016023	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Closed	12/24/2015 12:00:00 AM	ADDRESS	34.08758	-118.34425	1000Amp  temp power for site construction. consists of power to a crane, manlift, and spiderboxes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57641	18041-20000-22464	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.20696	-118.3417	new fire alarm for one story commercial	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57642	16041-20002-23923	411 S CATALINA ST	90020	10	135B197   557	5502012021	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.06673	-118.29556	[[[CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. DELTA 1 CHANGES ONLY. CHANGING INVERTER MODEL TO FRONIUS PROMO 10.0 ]]]]$0 permit fee due to State Senate Bill SB 1222PV2.  Install 59.8 kW DC roof-mounted PV system.  (176) modules with (4) 10kW transformerless central inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57643	18041-20000-33690	18200 W CHATSWORTH ST	91326	12	207B125   307	2731007001	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.2643	-118.52927	PV1.  Install 5.61 kW DC roof mounted grid tied PV system. (17) modules with 5.0 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57644	14041-20000-03100	4900 N RADFORD AVE	91607	2	168B169   181	2355013008	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.15972	-118.39194	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE8.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57645	14041-20000-11797	18764 W WILLOWTREE LANE	91326	12	207B121   571	2728029063	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Expired	05/26/2016 12:00:00 AM	ADDRESS	34.26271	-118.54172	PV1.  Install 6.912 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57646	16041-20001-34447	2358 N KIMRIDGE ROAD	90210	4	153B165   285	4388011041	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM			PC Approved	10/13/2016 12:00:00 AM	ADDRESS	34.11478	-118.39983	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of PV system on SFD, roof-mounted. Interconnect with 400A MSP.7.6kW ungrounded system. (22) 295W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57647	16041-10000-35968	10721 W STRADELLA CT	90077	5	144B149    78	4370006031	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.09326	-118.45398	New 1-story detached Accessory Living Quarter with basement, Building 3 of 3. Main building under plan check 16041-10000-35957.Plan check only. Note Permit is cover under 16010-30000-01646	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57648	19041-20000-26652	5068 W ROMAINE ST	90029	13	144B193  1083	5537024004	R3-1XL	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Apartment			07/11/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Permit Finaled	02/03/2023 12:00:00 AM	ADDRESS	34.08831	-118.30264	Full plan check for new 800A 240/120V 3ph-4w service, (25) panels with loads, a elevator, and a car charger.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57649	16041-20000-35234	8436 W 3RD ST 603	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.07301	-118.37448	ti to an existing commercial office building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 564.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57650	19041-10000-35091	1515 W 190TH ST Ste. 515	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	TENANT IMPROVEMENT WORK ON APPROX. 898 SF OF TOTAL FLOOR AREA IN SUITE# 515. INSTALLING LIGHTS. T-24 ENERGY ONLY. PERMIT FOR NEW CIRCUITS.BULDING PERMIT: 19016-40000-23525	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57651	13041-10000-12231	1411 S BARRY AVE 1-25	90025	11	129B149   487	4263020026	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			05/10/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.04628	-118.45709	FA FOR NEW 25 UNITS APT. 4 STORY OVER BSMT. 135 DEVICES AND PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57652	16041-30001-45776	380 WORLD WAY NBHS	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	02-06-2018 Changes to an approved set of plan LAX Project 5 Midfiled Satallite Concourse North(MSCN) NBHS. Changes include circuit revision and lighting layout. Changeshas been clouded and apply to delta 1 only. ***************************Proviouse Work Description**********************************Plan check for power and Title 24.  Provide normal and emergency power to North Baggage Building in LAX.Building permit #16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57653	14041-10001-24965	5824 N WILKINSON AVE	91607	2	174B165   149	2340014041	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.1764	-118.40404	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 10.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(40) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER: SOLAREDGE SE3800A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57654	18041-10000-47928	121 E WINDWARD AVE	90291	11	108A143   434	4238014006	C4-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	33.98815	-118.47182	TI IN AN EXISTING LOBBY OF A COMMERCIAL AREA (B of A). T-24 ONLY. BUILDING PERMIT: 18016-10000-40296	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57655	13041-10000-13880	8090 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2766.02, 2780.00	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Closed	06/19/2013 12:00:00 AM	ADDRESS	33.95166	-118.43325	CONDUIT ONLY PERMIT IN REFERENCE TO APPLICATION NUMBER # 13041-10000-11306.****************************************************************************13041-10000-11306 DESCRIPTION: TEMPORARY CONSTRUCTION SITE. INSTALLATION OF TEMPORARY TRAILERS. SCOPE OF WORK INCLUDES (1) 1200 AMP SERVICE, (3) 300 KVA TRANSFORMERS, AND (3)  1000 AMP SWITCHBOARD. PROJECT LOCATED IN A METHANE ZONE. APLLICANT HAS OBTAINED ADDRESS FROM ADRESSING COUNTER (APN: 4117-036-900)	N	N	Express Permit	06/10/2024 12:00:00 AM
57656	11041-10000-22841	515 S FLOWER ST 45TH FL	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	TENANT IMPROVENT IN OFFICE SPACESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57657	17041-20001-19464	2872 N LAS ALTURAS ST	90068	4	156A181   511	2428012008	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	Yes	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM			PC Approved	07/10/2017 12:00:00 AM	ADDRESS	34.12121	-118.34915	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 8 kWac and consist of (32) modules, (32) micro-inverters, and (1) load center. System interconnects with a 400-amp rated MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57658	11041-10000-05848	4414 S LONG BEACH AVE EAST	90058	9	112-5A213 136	5106004007	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM			PC Approved	04/05/2011 12:00:00 AM	ADDRESS	34.00332	-118.2429	T.I.  EXISTING OFFICE.  PER INSPECTOR REQUEST, TITLE 24 PLAN CHECK ONLY.  MODIFICATION TO LIGHTING FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57659	10041-10000-21337	812 E 59TH ST	90001	9	105B205   153	6007005900	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/26/2010 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	33.98709	-118.26081	Ti in a manufacture building. Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57660	14041-10000-06450	10560 W WILSHIRE BLVD 1ST FLOOR	90024	5	135B153   632	4326035***	[Q]R5-3-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.06229	-118.43273	Renovation of existing social room & exercise room in existing apartment high-rise building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57661	18041-20000-39640	12024 RICASOLI WAY	91326	12	216B109   373	2701084023	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	PIN	34.29188411	-118.58500462	Plan check for a PV1 roof-mounted PV system. System size is 14.95 kWdc/13.74 kWac-CEC and consists of (1) inverter, (46) modules, (1) load center, and (3) PowerWalls.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57662	13041-20000-03921	7323 W BEVERLY BLVD	90036	5	138B181   391	5526036017	C2-1VL-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	08/15/2013 12:00:00 AM	ADDRESS	34.07632	-118.34953	Full plan check. Low rise commercial building. PC fees per applicant, please verify during final fee period.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57663	13041-10002-07837	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Changes to permitted set of plans-Revision to the Lighting systemPLAN CHECK FOR LAX FIRST TIME TENANT DUTY FREE SHOP (BURBERRY STORE). 1250 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57664	12041-10000-06290	1506 W PALOS VERDES DR NORTH BLDG  C	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.77938	-118.30387	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building C.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57665	17041-20000-05572	21501 W VENTURA BLVD	91364	3	171B105     7	2168027031	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.16834	-118.599	"(2/21/2017)install outdoor lighting.  plan check for energy only.this is plan check only. the permit fees paid under application number 16044-10000-34762  (((REMOVE / INSTALL 36 POLES AND FIXTURES ""COMPLY WITH DEPARTMENT ORDER effective date01/31/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57666	13041-10000-25105	20000 W LASSEN ST	91311	12	201B113   205	2761012007	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	34.24979	-118.56889	PV1 10KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: SOLAREDGE SE5000A-US] [( 40) MOD: Trina {TSM-250PA05.08} with optimizers {POWERBOX 250W OP250-LV-MC4SM-2NA}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57667	17041-10000-14522	6033 W CENTURY BLVD	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Info Complete	06/02/2017 12:00:00 AM	ADDRESS	33.94572	-118.38954	Plan check for power and Title 24.  Renovation of existing office spaces at ground level and 3rd level in LAX terminal 6.  3 new subpanels with with lighting and receptacles.  New connected load exceeds 400 amps.  Total area = 20,445 sq. ft.     Building permit #17016-10000-10031	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57668	13041-20000-13986	1680 N VINE ST #200	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	RENOVATION OF INTERIOR LIGHTING IN OPEN OFFICE. WORK DONE IN SUITE 200. NEW FIXTURES. PC FOR T24 ENERGY ONLY. TOTAL AREA 2385 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57669	19041-20000-02479	1690 N DOHENY DR	90069	4	147B169    68	5561006040	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM			PC Info Complete	03/21/2019 12:00:00 AM	ADDRESS	34.10241	-118.38819	FULL PLAN CHECK FOR POWER AND ENERGY FOR EXISTING 4 STORIES S.F.D UPGRADING SERVICE TO 600AMP 120/240 1PH. SCOPE OF WORK INCLUDES GENERATOR, CIRCUITS EQUIPMENTS AND LIGHTIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57670	15041-20000-36502	1139 N ROBERTO LANE	90077	5	144B145    56	4377023045	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.09386	-118.45978	Plan check for a PV1 roof-mounted PV system. System size is 10.25 k Wac and consists of (41) modules, (41) micro-inverters, (1) combiner box, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57671	14041-20001-35184	707 W WILSHIRE BLVD 47 FLR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	[[[7/30/15 CHANGES TO T24 ENERGY ONLY PLANCHECK  (DELTA 2 CHANGES). UPDATE FIXTURE SCHEDULE AND REDUCE THE AMOUNT PREVIOUSLY INSTALLED]]]TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND CONTROLS TO EXISTING PANELS AND CIRCUITS.  PLAN CHECK FOR ENERGY AND EMERGENCY.  TOTAL SQUARE FOOTAGE 16570.  SCOPE OF WORK TO BE ON THE ENTIRE 47TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57672	18041-20000-18214	9173 N BURNET AVE	91343	7	198B145   451	2656023***	(Q)RD2-1, RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.23708	-118.46347	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (19) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57673	19041-20000-41034	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57674	15041-20000-37390	2301 S RAYMOND AVE	90007	8	123B197   338	5054002007	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.03531	-118.29772	PV1, roof mounted solar 5kW AC(16)modules: SunPower E20-327(1)inverter:PVI-5.0-OUTD-USStandar plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57675	15041-20000-18836	400 S HOPE ST #900	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for Title 24 only T.I. office space. Total area: 1749SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57676	16041-20000-14747	1108 S LOS ANGELES ST	90015	14	126A209   262	5145021022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.03808	-118.25716	TI WITH SERVICE UPGRADE TO 800 AMPS.  PC FOR POWER AND ENERGY.  ALL POWER EQUIPMENT NEW WITH NEW CIRCUITS.  TOTAL SQUARE FOOTAGE 2570.  BUILDING APPLICATION UNDER 15016-20000-27129.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57677	17041-20000-01880	1233 S NORTON AVE	90019	10	129B189   811	5081007021	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Apartment			01/19/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.04852	-118.3238	Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnecting with individual unit's 100A MSP. 3.8kW ungrounded system. (15) 300W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57678	11041-20000-02891	1860 S LA BREA AVE	90019	10	126B181   989	5067013030	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	09/23/2011 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04074	-118.34717	PLAN CHECK FOR POWER AND ENERGY FOR NEW 3-STORY COMMERCIAL BLDG .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57679	16041-10000-44460	17985 W PACIFIC COAST HWY	90272	11	126B113     6	4416005012	A1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.04184	-118.56677	Full plan check for a museum T.I, scope includes adding new load and modification on the lighting system in different location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57680	17041-20000-37254	8547 N AMESTOY AVE	91325	12	192B133    36	2690015023	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.22614	-118.50713	Note: $0.00 permit fee due to CA Senate Bill 1222pv1install roof mounted pv system sized 14.7kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57681	13041-10000-29930	17200 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.20827	-118.50773	PLAN CHECK FOR POWER AND ENERGY. PHASE 3 :TENANT IMPROVEMENTS AND EXPANSION OF CHASE BANK. 3 TOTAL PHASES.  PHASE 3:   ENERGY BEING CHARGED IN PHASE 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57682	17041-20000-17760	3649 N WOODCLIFF ROAD	91403	4	162A145   203	2279014018	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.13662	-118.46728	Plan check for solar pv system, roof-mounted on SFD.15.2kW ungrounded system. (54) 330W pv modules.Each module has a 400W power optimizer.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57683	16041-10000-22435	4620-4620 1/2 N EAGLE ROCK BLVD	90041	14	157-5A221  18	5474003006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.12792	-118.21732	T-24, PC FOR ENERGY ONLY FOR A NEW TWO-STORY SINGLE FAMILY DWELLING AND OFFICE DWELLING. SCOPE INCLUDES A NEW 200A 120/240V 1 PHASE, 3WIRE SERVICE, NEW PANELS, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 549 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57684	15041-10001-03554	904 E 116TH ST	90059	15	084B209   143	6084030023	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM			PC Approved	06/23/2015 12:00:00 AM	ADDRESS	33.92905	-118.25831	Expidite per applicant request(((((Plan check for PV1 roof mounted system 8.925kW with 35 modules.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57685	19041-20000-02309	24046 W SCHOENBORN ST	91304	12	192B089   153	2017037021	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.22122	-118.65065	PV1.  Install 2.835 kW roof mounted grid tied PV system.  (9) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57686	18041-10000-38947	5011 N LANKERSHIM BLVD	91601	2	171B173  1230	2353011002	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Info Complete	11/05/2018 12:00:00 AM	ADDRESS	34.16108	-118.37255	PLAN CHECK FOR TITLE 24 ONLY FOR - Tenant improvement to existing retail store to accessible ugrades to ramp and bathrooms. - TOTAL AFFECTED AREA = 1696 SFNote: Permit is paid under PCIS#18041-90000-34505	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57687	17041-20002-04511	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.10158	-118.3062	5.31.2017 - Plan check for modifications to approved set. Restroom walls rearranged, two L-1 fixtures removed. Changes clouded.==========Plan check for energy only. Interior TI of (E) restaurant. New lighting (incl. emergency). 2,862sqft.This supplemental 17041-20001-04511 to act as master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57688	14041-10000-11559	1380 N AVALON BLVD	90744	15	036B205  1118	7422005031	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	33.79097	-118.26304	Title 24 for commercial restaurant spaceArea = 3540 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57689	11041-10000-09910	517 S WILTON PL	90020		135B189   696	5504019020	R3-1		Wilshire	Greater Wilshire			Electrical	Electrical	Apartment			05/16/2011 12:00:00 AM			Verifications in Progress	02/13/2012 12:00:00 AM	ADDRESS	34.06469	-118.31433	NEW 6 UNIT TOWNHOUSE BUILDING 3 STORY OVER PARKING GARAGE.  EVERYTHING IS NEW.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57690	17041-10001-34889	14944 W CHATSWORTH DR	91345	7	207B149   200	2615023007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	34.26657	-118.45832	PC FOR REVISION TO APPROVED SET. SCOPE INCLUDES DIFFERENT PV MODULES (SAME OPTIMIZERS) WITH REDUCTION IN QUATITY (FROM 33 TO 31).AND CHANGES TO ROOF LAYOUT. NEW DC SIZE 9.920KWDC. THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER MASTER. ROOF-MOUNTED 9.075KW PHOTOVOLTAIC SYSTEM-2 SRTINGS , 7.6kw INVERTER AND 33 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57691	13041-10000-14526	264 S ALEXANDRIA AVE	90004	13	135B197   129	5518014023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Apartment			06/04/2013 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.06937	-118.29772	PLAN CHECK FOR FIRE ALARM FOR A TWO STORY BUILDING. 32 DEVICES AND A FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57692	16041-20000-10916	3227 E 6TH ST	90023	14	123A225   120	5186004040	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2041.20	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	PIN	34.0322502	-118.20132123	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.25 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57693	10041-20000-17057	825 E 4TH ST 1-53	90013	9	127-5A215 174	5163011028	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Apartment			08/30/2010 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.0435	-118.23728	Change from commercial to adoptive reused in Methane Zone area.  New service, panels, and branch circuits.  Plan check for energy and power.  Variance for separate fire alarm system submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57694	19041-10000-13392	2310 E ALCAZAR ST	90033	14	135A227    99	5202002020	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.06251	-118.19887	plan check for title 24 only for change of HID to LED lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57695	17041-10001-01481	10250 W SANTA MONICA BLVD 1720	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Approved	04/11/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	This is plan check only for changes to approved set, replacing dimming panel from Eaton to Blue Box.Permit is under 17041-90000-01481, Full plan cehk is under 16041-10000-37608	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57696	18041-10001-35822	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	REVISIONS TO PERMITTED SET OF PLANS-  XFMR SUPPLIES (E) PANEL EP3 WHICH SUPPLIES (E) UPS WHICH SUPPLIES (N) PANEL UPS1 . CKTS FROM EPS ARE LOCATED TO PANEL UPS1; DWP SWITCH ADDED OUTSIDE & EQUIPMENT REAARANGED TO ACCOMODATE THE CHANGES;18 NEW CKTS ADDED; ALL CHANGES ARE CLOUDED AND MARKED DELTA 1DESIGN BUILD. Full plan check for a office/warehouse TI. Scope include new lighting, and equipment with a total area of 312,000-SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57697	11041-10000-00882	8640 W 3RD ST	90048	5	138B169   564	4334011021	C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Public Safety Only			01/14/2011 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	34.07338	-118.38114	New Fire alarm system. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57698	16041-20001-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	34.09822	-118.31812	"[[[[4/14/17 CHANGES TO APPROVED SET.  REMOVING COMPLETE LIGHTING IN TENANT SPACES ON FLOORS 7-15 ]]]]""COMPLY WITH DEPARTMENT ORDER effective date04/24/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""Plan check for power and energy. Core and shell for new 16-floor Highrise Office Building with Ground Floor Retail. 1200A, 4160V service. T24 Area: indoor-463,185sqft; outdoor: 15,272sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57699	15041-10000-24894	520 W MANCHESTER AVE	90044	8	097-5A201 280	6038001901	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	33.95992	-118.28343	POWER PLAN CHECK  FOR REPLACEMENT OF A  GENERATOR IN AN EXISTING PUMPING PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57700	19041-20001-05906	4725 N EL CABALLERO DR	91356	3	168B121   335	2176030032	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.15585	-118.54571	PV1.  Install 13 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (40) modules with 10 kW rated string inverter and (2) 13.5 kWh battery storage units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57701	17041-10000-04427	634 S CROCKER ST	90021	14	126A213   121	5147027040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.04081	-118.24494	PC for inddor Title 24. Removing HID fixures and replacing them with new LED fixtures. Area: 25,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57702	13041-20000-00171	11940 W WESTMINSTER AVE	90066	11	114B153   141	4249016029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.01201	-118.4331	New 5.52KW rooftop mounted PV system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57703	15041-10000-19761	3554 S MOUNTAIN VIEW AVE	90066	11	114B153   261	4248022029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.01106	-118.4341	PV.1 ROOF MTD., 7.5 KW DC, 30 PANELS, 30 MICROINVERTERS, NEW 125 SUBPANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57704	18041-20000-09428	6255 W SUNSET BLVD Suite 810	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,155 sq. ft.Note: Building application has been generated under 18016-20000-05425	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57705	14041-10001-07890	1409 S WALGROVE AVE	90291	11	114B149   683	4244003009	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			Reviewed by Supervisor	04/09/2014 12:00:00 AM	PIN	34.00767071	-118.45473846	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US(17) MODULES: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57706	12041-20003-24240	18452 W HALSTED ST	91325	12	201B125   404	2764008001	(T)(Q)R3-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM			PC Approved	08/03/2015 12:00:00 AM	ADDRESS	34.24439	-118.53563	Changes to approved set.  Sump pumps to be changed to 240V (1.5 HP) with 208/240 transformer.  Light fixtures in stairwell to be changed.   (50% Southland Lighting with integral occupancy sensor and 90 min battery backup and 50% Southland Lighting with 90 min battery backup but no occupancy sensor).  *****Previous Work Description*****   New 47 unit apartment. Variance is being submitted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57707	15041-20000-03727	2821 N JOHNSTON ST	90031	1	141A223   296	5206011012	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1993.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	05/12/2015 12:00:00 AM	ADDRESS	34.07974	-118.21073	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.44KW. (16) EnPhase M215-IG microinverters with (16) 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57708	19041-10000-51535	811 E AMOROSO PL	90291	11	108B149   718	4241025019	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	01/05/2021 12:00:00 AM		Permit Finaled	03/02/2021 12:00:00 AM	ADDRESS	33.99282	-118.45847	$0 FINAL FEES PER AB1414PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 8KWac, SYSTEM INCLUDES 88 TESLA SOLAR ROOF TILES, A  CENTRAL INVERTER (M8-TL-US) A NEW 225A LOAD CENTER WITH A NEW ESS. INTERCONNECTED TO AN EXISTING 200A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57709	15041-20001-28973	17074 W CALAHAN ST	91325	12	198B133   593	2692019032	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM			Reviewed by Supervisor	09/18/2015 12:00:00 AM	ADDRESS	34.2363	-118.50542	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 12.0kW with 44 modules  SUNPOWER 327 WATT and 2 inverters(6.0kW each)}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57710	15041-20000-14817	10560 N COLLETT AVE	91344	12	207B141   567	2668007012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.26279	-118.4835	installation of new roof mounted solar PV array.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57711	17041-10000-18822	4960 N BALBOA BLVD	91316	5	171B133   723	2259005904	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.16115	-118.50088	PC for energy only, Outdoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 21,750 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57712	14041-10000-34728	8556 S EMERSON AVE UNIT 2	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	02/24/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 2 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57713	19041-10000-02783	1701 E CESAR E CHAVEZ AVE	90033	14	130-5A221 204	5174007047	C2-1-RIO-CUGU, RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.05126	-118.2173	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57714	19041-20000-27762	6100 W CENTER DR 1190	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	33.97733	-118.3922	ti to an existing commercial building.  adding new lighting new controls to existing panels.   plan check for interior energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57715	18041-10004-07709	8913 W 25TH ST	90034	10	126B169  1229	4302015022	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.03864	-118.3858	CHANGES TO AN APPROVED SET OF PLANS CHANGES INCLUDE THE ADDITION OF A DISCONNECT. NOTED UNDER DELTA 2 CHANGES ONLY.___PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING.  CONISIT OF 24 MODULES(Trina Solar 300W) AND A CENTRAL INVERTER (DELTA SOLIVIA 5.2) . SYSTEM SIZE IS 5.2KWac AND 7.2KWdc.SCOPE INCLUDES NEW LOAD CENTER (200A each).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57716	13041-20000-14095	601 S FIGUEROA ST FLOOR 21	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	T24 FOR HIGHRISE OFFICE SPACE 21ST FLOOR. SCOPE OF WORK 765 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57717	14041-10000-27077	403 S HIGHLAND AVE	90036	4	135B185   254	5507013001	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM			Corrections Issued	10/01/2014 12:00:00 AM	ADDRESS	34.06668	-118.33875	PV1,  New roof mounted solar PV system.  Total system size = 6 kWac. 25 modules and 1 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57718	15041-10000-03484	15301 W VENTURA BLVD P-17	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	34.15411	-118.46654	Title 24 plan check only.  Total area = 85 sq. ft.T.i. to existing commercial restaraunt space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57719	16041-10000-20660	5604 S FORTUNA ST	90011	9	108B213   402	5105015020	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	33.9919	-118.24543	PV1 INSTALL NEW 2.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(10) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57720	19041-20000-44242	7600 N BALBOA BLVD 111	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.2087	-118.50093	PLAN CHECK FOR TI REMODEL, ENERGY ONLY T24. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 3210 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57721	10041-10000-17266	1375 N WESTERN AVE	90028	13	147A193   170	5544030055	C2-1	Central	Hollywood	Hollywood Studio District		1909.01, 1911.10	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	PIN	34.09654211	-118.30960546	CHANGE PORTION OF EXISTING BLDG FROM REPAIR GARAGE TO RESTAURANT, 5800 SF, TYPE V-B CONSTRUCTION, OCCUPANCY CHANGE FROM F-1 TO A-2. TI CONSISTS OF INTERIOR WORK, NEW RESTROOMS, EQUIPMENT, DINING/SEATING.  REF.#10042-10000-19412.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57722	13041-10000-13509	13151 W STAGG ST	91605	2	189B157   822	2303010005	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.2116	-118.42004	PV1 ROOF MOUNTED SOLAR INSTALLATION USING TRANSFORMERLESS INVERTERS ON NON STANDARD PLANS. SYSTEM SIZE IS 5.232 KW USING TWO STRINGS OF 8 MODULES AND A SINGLE INVERTER. [MODULES: SUNPOWER # SPR-327NE-WHT-D |||| INVERTER: POWER ONE PVI-5000-OUTD-US]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57723	10041-10000-07507	2000 S CENTRAL AVE	90011	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			04/23/2010 12:00:00 AM			PC Approved	04/23/2010 12:00:00 AM	ADDRESS	34.02249	-118.25156	DEVELOPEMENT OF FIRST TENANT SPACE; SHELL PERMIT INCLUDE TENANT PANELBOARD AND SOME CIRCUITS.  For permit see application # 10041-10002-01626.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57724	18041-20001-38383	19615 W ROSCOE BLVD	91324	12	192B117   699	2783012012	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/18/2018 12:00:00 AM	PIN	34.22105589	-118.56075713	PV1.  Install 16.2 kW roof mounted grid tied PV system.  (45) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57725	19041-20001-46994	20228 W VIA GALILEO	91326	12	219B113   175	2701043011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.29488	-118.57462	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE IN PV MODULE MODEL, SYSTEM DC SIZE CHANGED FROM 11.725 KW TO 12.25 KW, AC SYSTEM SIZE UNCHANGED, CHANGE MADE TO COVER PAGE, SINGLE LINE, AND ROOF LAYOUT PAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57726	17041-10000-34498	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.04797	-118.25815	Energy plan check for the first floor of a commercial building. Total plan check area is 3,155 SQ FT. Rewiring ciruits to SMP3 and SMP2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57727	16041-10000-40513	11611 W SAN VICENTE BLVD STE 650	90049	11	132B145   488	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.0541	-118.46261	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE ON SUITE 650. TOTAL AFFECTED AREA IS 1991 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57728	10041-20000-13178	21031 W VENTURA BLVD 3,5,7 flr	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	08/18/2010 12:00:00 AM	PIN	34.16717222	-118.59179488	energy plan check 3,5,7	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57729	18041-10000-31351	8500 W BEVERLY BLVD STE 153	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Info Complete	08/17/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a change of use from a restaurant to a nail salon. Scope includes new lighting and equipment with a total area of 950-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57730	12041-10000-29747	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	ADDRESS	34.04842	-118.33486	T24 FOR CORE/SHELL. OLTG. METHANE. power and lighting for future retail. the retail building is next to a parking lot.appplicant dropped plans off on thursday, 12/6/12, by Tran but PCIS was down so she left plans and check. payment receipt will be faxed to 562-628-8005	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57731	12041-10000-16889	626 S LORNA LANE	90049	11	132B145   286	4401012007	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.05636	-118.46918	New 9.16kw rooftop PV system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57732	16041-20000-16183	23210 W VENTURA BLVD	91364	3	171B093   722	2044026045	(Q)C1-1VLD, (Q)P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.16209	-118.63143	Change of use from retail to veterinary clinic.  New 800A 120/240V three phase service.  Plan check for power and energy.  2865 sq ft.Building permit under 16016-20000-09634	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57733	12041-10001-28877	5419 W SUNSET BLVD	90027	13	147A193    65	5544022053	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	34.09827	-118.30768	(6/24/2014) CHANGES TO APPROVED SET PER INSPECTORS REQUEST. CHANGES TO T24 ENERGY ONLY. CHANGES ARE CLOUDED.T.I.  2 story building with open parking on top.  Current use of the space is retail, converting it to an adult trade school that will occupy the whole building.  New panels, circuits and lighting.  Full plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57734	14041-20000-10131	6028 S EILEEN AVE	90043	8	105B181   741	4004023007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	33.98453	-118.34272	pv1 single family dwelling. total system size 3.8kw ac using transformerless inverter nonstandard plan. using power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57735	15041-20000-06437	20321 W AETNA ST	91367	3	177B113   145	2149008010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.17902	-118.57625	""" 0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (58) modules, (3) inverters, and (1) 125-amp rated load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57736	16041-10001-28519	10161 N WHITE OAK AVE	91325	12	204B129   262	2734004022	RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	34.25577	-118.52003	Expedite fees only.         Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 12 kWac.  Two SMA SB6000TL inverters with 37 modules total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57737	17041-10000-44999	937 N SYCAMORE AVE	90038	4	144B181   686	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.08824	-118.34291	PC FOR WAREHOUSE TI FOR TITLE 24 ENERGY ONLY.  SPLITING EXISTING SPACE INTO TWO SPACES FOR FUTURE TENANTS. INSTALLING MINIMUM LIGHTING AND EXIT SIGNS REQUIRED PER BUILDING CODE.SCOPE INCLUDES NEW LIGHTS AND PANELS. TOTAL AFFECTED AREA  6558 SQ.FT. B# 17016-10000-33840VOLUNTARY STRUCTURAL RETROFIT OF (E) LIGHT MANUF / WAREHOUSE. NO CHANGE OF USE.***  Project is subject to Change of Use per  ZA-2017-1968-CU, Resubmittal is required for change of use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57738	17041-20001-11886	7842 N MELBA AVE	91304	12	189B093   505	2020023007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM			PC Approved	04/28/2017 12:00:00 AM	ADDRESS	34.21298	-118.63443	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (2) inverter, (84) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57739	19041-20000-41209	20828 W PINECONE CIR UNIT# 34	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	04/13/2020 12:00:00 AM	ADDRESS	34.29564	-118.58799	PV roof mounted system, PV system size: 4.2KW with 12 AC Modules connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57740	13041-10000-01016	12533 W CUMPSTON ST	91607	5	174B161   729	2346011031	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.16968	-118.40647	PV1 7.92KW STD PLAN 1 STORY. 33 MODULES ROOFMOUNT. INV: FRONIUS10.0-1.   module TSM-240 PC/PA05	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57741	19041-20001-21689	202 S MAIN ST	90291	11	111B141   444	4286003001	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM			PC Approved	10/09/2019 12:00:00 AM	ADDRESS	33.99763	-118.47899	10/9/19CHANGES TO APPROVED SET DELTA (A) ONLY, CHANGES IN LIGHTS. <<<TI to (E) commercial kitchen.  Plan check for energy.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57742	18041-10000-40570	222 N HARVARD BLVD	90004	10	138B193   524	5517017010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Approved	10/24/2018 12:00:00 AM	ADDRESS	34.07602	-118.30417	TI IN AN EXISTING ONE STORY OFFICE BUILDING. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY. PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER 18041-10000-40888	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57743	13041-10000-02302	334 S MAIN ST #1106	90013	14	129A213   129	5148001018	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	08/01/2013 12:00:00 AM	ADDRESS	34.04841	-118.24668	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT FOR NEW RESTAURANT SUITE #1106.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57744	19041-20000-49832	9657 N LUBAO AVE	91311	12	201B113   744	2761025013	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.24548	-118.56873	PV1. INSTALL 11.34 KW DC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER(SE10000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57745	10041-20001-25893	705 W 34TH ST	90089	9	120A201   206	5123023024	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Approved	06/01/2011 12:00:00 AM	PIN	34.02214675	-118.28186522	USC - UNIVERSITY CLUB REMODEL AND ADDITION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57746	19041-20000-13193	22301 W MARILLA ST	91311	12	201B101   280	2727006033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.24767	-118.61294	NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 9KW DC/7.6KW AC. SCOPE INCLUDES (25) SOLARIA POWERXT-360R-PD PV MODULES WITH SE P370 POWER OPTIMIZERS, AND A SE7600H INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57747	19041-20000-12264	2020 N MANDEVILLE CANYON ROAD	90049	11	138B137   462	4426023017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.07235	-118.49511	addition of (2) tesla ESS 5KW each.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57748	19041-20000-20717	21715 W COHASSET ST	91303	3	186B105  1088	2111003028	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	PIN	34.20669202	-118.60216064	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.32KW DC/3.84KW AC. SCOPE OF WORK INCLUDES (12) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57749	18041-20000-08671	6032 W ROMAINE ST 1-6	90038	13	144B189   866	5534025007	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.08872	-118.32337	INSTALLATION OF A FIRE ALARM SYSTEM. 61 DEVICES 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57750	18041-10000-28128	4733 W SUNSET BLVD	90027	13	147B197   604	5543012018	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	Yes	1912.01	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	34.09833	-118.29305	PLAN CHECK FOR POWER FOR - INSTALL OF A FUEL CELL GENERATOR WITH CONCRETE PADS - SYSTEM SIZE = 900KVA CONSISTING OF 3 FUEL CELLS(BLOOM ENERGY - 300KVA EACH)***See comment on back of B-form application***	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57751	15041-10000-36699	6500 W WILSHIRE BLVD 1800	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.06371	-118.3703	PC FOR ENERGY. HIGH RISE BUILDING. TOTAL AREA 4889 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57752	19041-20000-30275	243 E 5TH ST	90013	14	127-5A213  13	5148010006	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM			Verifications in Progress	10/04/2019 12:00:00 AM	ADDRESS	34.04537	-118.24623	PV2.  Install 46.44 kW DC / 41.74 kW AC roof mounted grid tied PV system. (172) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57753	14041-10000-10604	900 N ALAMEDA ST 4TH FLOOR	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.05855	-118.23671	PLAN CHECK FOR ENERGY ONLY FOR EXISTING HIGHRISE OFFICE BUILDING. SCOPE OF WORK IS ON THE 4TH FLOOR CORRIDOORS AND ELECTRICAL ROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57754	14041-20000-01919	5337 W LA CRESTA CT	90038	13	141B193   219	5535011021	R2-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Expired	02/25/2016 12:00:00 AM	ADDRESS	34.08563	-118.31066	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57755	17041-20000-22164	19339 W LORNE ST	91335	3	189B117   202	2105016013	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.21656	-118.55513	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists (1) inverter and (34) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57756	15041-10000-07721	10151 N RESEDA BLVD	91324	12	204B125   215	2729011004	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.25544	-118.5364	NEW RESTAURANT IN NORTHRIDGE SHOPPING CENTER- GEN KOREAN BBQ HOUSE- PLAN CHK IS FOR TITLE 24 (NEW LOAD IS LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57757	15041-10000-08189	3435 W WILSHIRE BLVD #104	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM			PC Approved	03/20/2015 12:00:00 AM	ADDRESS	34.06194	-118.29866	Energy plan check for an office T.I . Total area is 1004-SQ feet. Inspection fee is paid under permit # 15041-10000-06071	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57758	14041-20000-04389	18833 W RAYEN ST	91324	12	195B121   229	2770001016	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.23197	-118.5437	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57759	14041-20000-28701	8761 N AQUEDUCT AVE	91343	12	195B141   559	2672011009	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.23007	-118.47436	PV1 SDF TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 16 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57760	11041-10000-17305	7920 W SUNSET BLVD # 3rd fl	90046	5	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.09787	-118.36238	remodeling of officesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57761	19041-30000-09337	2029 S CENTURY PARK EAST 16th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is common area restrooms on the 16th floor. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57762	19041-20001-25797	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	Revisions to approved set of plans.  Minor power and lighting changes delta 1 only; relocation of distribution equipment.  (((POWER AND ENERGY PLAN CHECK BY APPLICANTS REQUEST. T24 INCLUDED TOTAL SQUARE FOOTAGE = 3,047 SF. 1 225A AND 1 200A PANEL, AND 1 75KVA TRANSFORMER RELOCATED WITH 1 NEW 100A PANEL ADDED.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57763	18041-20000-30457	6430 W SUNSET BLVD 6th Floor	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.09782	-118.32979	Tenant improvement to (E) commercial office space in highrise building.  Plan check for energy.  Building permit under 18016-20000-24123.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57764	13041-10000-20811	1740 S CRENSHAW BLVD	90019	1	126B197   806	5075036024	M1-2	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.04243	-118.32944	FA NEW FA FOR (E) BLDG FOR BOARDING HOUSE. 23 devices and 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57765	18041-10000-27198	4616 W DE LONGPRE AVE 4TH FLOOR	90027	13	147B197   891	5542017033	C2-CSA1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.0968	-118.29007	PLANCHECK FOR POWER AND ENERGY. CONVERSION OF OFFICE TO EXAM ROOMS. OSHPD 3. 675 SQFT.  4TH FLOORBUILDING PERMIT # 18016-10000- 23161  CONVERSION OFFICE AREAS TO EXAM ROOMS INCLUDING NEW NON-BEARING WALLS, DOORS & HARDWARE, CEILINGS, LIGHTING, AND MODIFICATIONS TO MECHANICAL AND ELECTRICAL SYSTEMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57766	14041-20000-05025	1731-1747 S WESTWOOD BLVD	90024	5	129B153   302	4324028047	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.05138	-118.43868	T.I. to existing building for addresses 1731-1747.  Install outdoor lighting in facade.  Plan check for energy.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57767	16041-20000-45670	8007 N MAESTRO AVE	91304	12	189B093   267	2020018031	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.21532	-118.63983	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating the main breaker to 175A. 11.52kW ungrounded system. (36) 345W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57768	12041-10000-30933	12115 W VENTURA BLVD	91604	2	162B165   107	2367016014	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			12/26/2012 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.14366	-118.39605	t.i of retail to retail. clothing to clothing. title 24 counter plan check. emergency lights. 4.6k sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57769	18041-20000-08347	21600 W OXNARD ST Suite 800	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,335 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57770	12041-10000-04983	13357 W RIVERSIDE DR	91423	4	168B157   293	2359019008	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.15778	-118.42455	Ti in the El Pollo Loco Restaurant. EPC is for T24. (Emergency lights are existing to remain)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57771	19041-20000-02090	24235 W STONE BEND LANE	91304	12	192B089   179	2017038011	RE11-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.21998	-118.65543	PV1.  Install 2.835 kW roof mounted grid tied PV system.  (9) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57772	14041-20000-07713	13897 N ELDRIDGE AVE	91342	7	228B153   687	2503003019	RE11-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			Reviewed by Supervisor	04/03/2014 12:00:00 AM	ADDRESS	34.32445	-118.43353	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57773	13041-20000-23518	1050 S FLOWER ST	90015	14	127-5A207 206	5138013072	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	08/28/2013 12:00:00 AM	ADDRESS	34.04303	-118.26381	pc for t24 energy only. common area lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57774	15041-10000-29297	232 W 2ND ST	90012	14	130-5A213  31	5149008031	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Issued	10/09/2015 12:00:00 AM	ADDRESS	34.05206	-118.2465	PC FOR POWER FOR TWO 600A 480/277V SERVICES.  SCOPE INCLUDES TEMPORARY POWER TO BE INSTALLED IN CONSTRUCTION SITE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57775	16041-20001-06784	13309 W WOODBRIDGE ST	91423										Electrical	Electrical	Apartment			02/26/2016 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	34.14771	-118.42307	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM FOR APARTMENT. SYSTEM SIZEl 15.6 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57776	10041-20000-09833	11111 W SANTA MONICA BLVD UNIT 700	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles			2673.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	06/17/2010 12:00:00 AM	ADDRESS	34.04771	-118.44481	TI WORK IN PORTION OF OFFICE AREA. THIS P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57777	19041-20000-49536	1515 E 15TH ST	90021	14	121-5A213 395	5130019031	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	10/01/2020 12:00:00 AM	ADDRESS	34.02483	-118.24354	PLAN CHECK FOR TENANT IMPROVEMENT. SCOPE OF WORK INCLUDES T24, (36) BRANCH CIRCUITS, (20) 3.1-5 KVA EQUIPMENT, (5) 5.1-20 KVA EQUIPMENT, (1) 20.1-50 KVA EQUIPMENT, (3) 50.1-100 KVA EQUIPMENT, AND (4) PANELS. TOTAL SQUARE FOOTAGE = 9530 SFBLDG PERMIT UNDER 19016-20000-25270	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57778	17041-20001-19001	827 N VINE ST BLDG B	90038	13	141B185   150	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.08598	-118.32689	1/10/19plan check only for supplemental changes to approved set. scope includes change from fully rated to series rating, removal of digital meters, and update to load and available fault current calcs. address changed to correct address from 825 to 827 N Vine st.Plan check for power and energy. New 3-story office building (Bldg B). Core and shell. Methane zone.3,000A service @ 480V 3ph-4W.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57779	16041-20001-44682	5509 N SHOUP AVE	91367	3	174B101   374	2040016002	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.1704	-118.61482	12/21/2016 Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (34) modules. Standard plan is not being used. *****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57780	18041-20000-33589	3411 S 12TH AVE	90018	10	120B185  1541	5044006031	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM	ADDRESS	34.02518	-118.33182	NEW 800 AMP SERVICE CONVERT CLASSROOMS TO JOINT LIVE/WORK QUARTERS.PLAN CHECK FOR POWER AND ENERGY.BUILDING APPLICATION 17016-10000-27986	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57781	15041-10000-28454	5051 W RODEO ROAD	90016	10	120B177  1408	5046013006	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			Reviewed by Supervisor	09/16/2015 12:00:00 AM	ADDRESS	34.02173	-118.35358	DEMO ALL INTERIOR OF EXISTING BUILDING AND INSTALL STORAGE MODULES.  CHANGE OF USE FROM OFFICE TO STORAGE BUILDING.  NEWLY CONNECTED LOAD > 400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57782	16041-10000-14141	230 N RIDGEWOOD PL	90004	4	138B189   547	5516013006	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.07545	-118.31444	PV1 NEW ROOF MOUNTED SOLAR SYS TIED TO AN EXISTING SOLAR SYS. 21 MOUDELS  AND ONE 3.6KW INVERTER.  NEW LOAD CENTER AND DE-REATED THE MAIN BREAKER. NEW TOTAL SYS SIZE 6.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57783	14041-10000-34720	8556 S EMERSON AVE UNIT 7	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	01/21/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 7 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57784	18041-20001-06783	5440 N TROOST AVE	91601	2	174B169  1207	2348001037	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Approved	11/07/2018 12:00:00 AM	ADDRESS	34.1697	-118.38649	11-07-2018 Chages to an approved set of plan. Changes include update lighting fixture control system. All Changes has been clouded area delta 2 and 3. plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57785	16041-10001-45066	10250 W SANTA MONICA BLVD UNIT 2830	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set: removed all bug eyes, added inverter as an emergency back-up power, provided photometric.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57786	19041-10000-26394	883 S CRENSHAW BLVD	90005	4	132B189   737	5090033016	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.05706	-118.32203	Plan check for a new sprinkler monitoring system located in a 3-units apartment building. Scope includes (1) fire alarm panel and (10) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57787	15041-20001-20523	21031 W VENTURA BLVD 502	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	PIN	34.16717222	-118.59179488	Plan check for title 24 only T.I. office in existing space. Total indoor area: 2372 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57788	13041-10000-23738	460-468 S LA BREA AVE	90036	4	135B181   575	5507009014	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.06521	-118.34382	Plan check power and energy for new restautant/bakery space (460-468 La Brea). Existing service. In methane zone, no installation below grade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57789	15041-20000-12909	13119 MIRA MAR DR	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	PIN	34.31120672	-118.40409465	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (17) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57790	15041-10000-16357	1423 S FLOWER ST	90015	14	126A205   181	5134009006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.0378	-118.26853	TI-24 TO AN (E) BUILDING. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL SQ. FT. 4416 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57791	11041-10001-14765	333 S GRAND AVE 25Th Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			Corrections Issued	07/26/2011 12:00:00 AM	ADDRESS	34.05271	-118.25179	FIRE ALARM SYSTEM ON THE 25TH FLOOR.  EPC APP# 11041-10000-14765.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57792	19041-10000-31060	15500 W ROSCOE BLVD	91406	6	192B145   438	2654038047	[T][Q]CM-1VL	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Issued	01/21/2020 12:00:00 AM	ADDRESS	34.22124	-118.4705	PC FOR T24 ONLY, TOTAL NEW CONNECTED LOAD IS UNDER 400A, SCOPE OF WORK IS A TI TO AN EXISITNG AUTOMOBILE SHOWROOM. SCOPE OF WORK INCLUDES NEW LIGHTING, CONTROLS, CIRCUITS ARE EXISTING. TOTAL AFFECTED AREA IS 35,674 SQFT. B#: 19014-10000-04310	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57793	14041-10000-33244	5263 N BAKMAN AVE	91601	2	171B173   355	2350017019	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.16663	-118.37756	Plan check for the installation of a new manual fire alarm system in a A-3 occupancy (temple; place of assembly). Consists of (47) devices and (1) FACU.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57794	12041-10000-08269	707 W WILSHIRE BLVD 4875	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/11/2012 12:00:00 AM			PC Approved	04/11/2012 12:00:00 AM	ADDRESS	34.04893	-118.2572	Tenant Improvement in offices-new circuits and luminaires; plan chk is for title 24; permit obtained on 12041-90000-07158	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57795	16041-10000-02034	1117 1/2 S HOPE ST	90015	14	127-5A207 262	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.04196	-118.26367	ALTERATIONS IN EXISTING SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57796	13041-20000-23967	6736 N LAUREL CANYON BLVD # 360	91606	2	180B165    87	2322010037	C1-1VL, P-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.04	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.19322	-118.39632	T24 FOR EXISTING OFFICE. TOTAL SQRFT 2457.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57797	14041-10000-04627	9616 W PICO BLVD	90035	5	132A167   260	4306001037	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.05497	-118.39811	(((2/19/2014: PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT (STARBUCKS) IN RALPHS STORE. PLAN CHECK HAS BEEN APPROVED FOR THE RALPHS ON 13041-10000-15927)))pc for power and energy. interior remodel of the (e) ralphs store, removal and replacement of sales area and food prep area fixtures with all associated electrical items. remodel (e) interior lighting	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57798	12041-10000-13607	9144 N DEERING AVE	91311	12	198B105   160	2746010031	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.237	-118.59594	Plan check for new installation of new sprinkler monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57799	15041-20001-36328	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	Expedite per applicant request{{{{{{{Plan check for PV roof mounted system. System size: 720kW with 3,200 modules with 20 inverters(36kW @ 277/480V)Note: Building Application # 15041-20000-04961}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57800	13041-10003-14606	217 E 8TH ST	90014	14	127-5A211 327	5145003005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Closed	09/21/2015 12:00:00 AM	ADDRESS	34.04155	-118.25168	changes to approved set of plans. PC for t24 plan check  only. changes under delta5. total area  15799 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57801	17041-20000-10406	21300 W VICTORY BLVD Suite 820	91367	3	180B105    55	2149001031	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,916 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57802	19041-10000-20060	8600 N WILBUR AVE	91324	12	192B121    31	2785023008	[Q]M1-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.22676	-118.54464	Replace fluorescent troffers with new LED retrofit kits -  Indoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57803	16041-10000-30461	5300 S HOOPER AVE	90011	9	108B209   327	5104012017	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	33.99462	-118.25196	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.TOTAL AREA (OUTDOOR) 7307 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57804	19041-10000-14656	970 N MORAGA DR	90049	5	141B145   222	4368019023	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/06/2021 12:00:00 AM	ADDRESS	34.08202	-118.46797	Plan check for a 17.6KW AC / 17KW DC roofmounted system with (1) load center, (2) inverters, (54) modules and optimizers interconnecting through the service. Final inspection fees are $0 due to Sentae Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57805	18041-20000-11097	11740 W SAN VICENTE BLVD Suite 108	90049	11	129B145    75	4265006074	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.05308	-118.4669	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is change of use from retail to beauty salon/tenant improvement. Total lighting area = 941 sq. ft.Note: Building application has been generated under 18016-20000-08919	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57806	15041-10000-23326	3919 W BEVERLY BLVD	90004	13	138B197   299	5520020008	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.07647	-118.2939	TI TO AN EXISITNG MEDICAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANELS.  FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57807	17041-20001-40905	24022 W SCHOENBORN ST	91304	12	192B089   149	2017037017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	34.22111	-118.64972	expeditepv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57808	16041-10000-31862	1800 W 11TH ST	90006	1	129A203   133	5136020026	C1-1-HPOZ	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Apartment			09/08/2016 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.04867	-118.27781	Full PC for a new 3 story 25 unit apartemtn building. 3 typical units. New serivce 1200A 120/208 3phase 4wire. Total sqft = 7007. Note *** Outdoor title 24, and green building complicance fees were not added on submittal fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57809	16041-10000-33500	5315 E CONEY ROAD	90032	14	138A237   183	5221006016	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.07269	-118.16805	PV1 roof mounted solar system installation to a single family homel. Installing 20 solar system directly to a central inverter rated at 4.6 Kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57810	14041-10000-27110	7407 W COASTAL VIEW DR	90045	11	099B157   530	4114035001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	33.96452	-118.42662	Standard Plan PV1, 6Kw roof-mounted system including (1) Solaredge SE6000A inverter, (25) Kyocera KD255G  modules and power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57811	10041-10000-10934	10341 N WOODLEY AVE	91344	12	204B137   113	2679007039	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM			Reviewed by Supervisor	06/21/2010 12:00:00 AM	ADDRESS	34.25922	-118.48504	New service and panelboard for a church. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57812	13041-20000-25297	515 W 101ST ST	90044	8	091-5A201 161	6054020028	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	33.94472	-118.2833	PV1 TRANSFORMERLESS INVERTER. TOTAL SYSTEM SIZE 3 KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57813	17041-10000-06394	5019 N LANKERSHIM BLVD	91601	2	171B173  1230	2353011002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.16132	-118.3727	PC PC FOR POWER ONLY. SCOPE INCLUDES A NEW 600A SERVICE/ DISTRIBUTION BOARD FOR A A SHOPPING CENTER (BUILDING 1 OF 3).NOTE PLANS ARE SUBMITTED UNDER THE SAME SET OF PLANS. B#16014-30000-02106	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57814	17041-10000-18985	1380 W HILL DR	90041	14	163-5A227  55	5691007009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.14389	-118.19458	PC FOR PV SYSTEM WITH BATTERY STORAGE UNIT. PV RATED 5.2KW AC WITH 20 MODULES AND BATTERY UNIT RATED 5.8KW WITH A CAPACITY OF 13KWH. INSTALL SOLAR LOAD CENTER. ZERO DOLLARS FOR PERMIT DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57815	10041-10000-23614	1401 W PACIFIC COAST HWY	90710	15	033B193    45	7410009042	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	33.7896	-118.30157	Ti in a 7-11 store. EPC is for T24 and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57816	18041-10000-21597	300 S GRAND AVE 31ST FLR.	90071	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	34.05283	-118.25116	Plan check for POWER AND ENERGY FOR OFFICE IN A HIGH RISE BUILDING ON THE 31ST FLOOR. SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 20687 SQ.FT (B# 18016-10000-16970)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57817	18041-20000-26258	505 W 31ST ST	90007	9	120A203    80	5123020009	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			07/13/2018 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	08/26/2021 12:00:00 AM	ADDRESS	34.02382	-118.27755	Plan check for power and energy for (N)Building 7 story 73 units Affordabld Housing 2000A 208/120Volt 3Phase 4W. Total area: 60,175 sq ft. B#16010-100000-06041	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57818	16041-20001-39707	1205 E 6TH ST	90021	14	126A215   332	5164009012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			11/17/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.03828	-118.23807	RSES expedited plan check fee per applicant request.PV2.  Install 4.80 kW DC roof mounted grid-tied PV system.  (15) modules with (1) 10.0 kW rated central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57819	14041-20000-11560	417 W 57TH ST	90037	9	108B201  1048	5001036053	RD2-1	South Los Angeles	Southeast Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	33.99068	-118.28123	PV1.  roof mounted system with (16) Canadian solar CS6P-250P modules and (16) Enphase M215 240v micro inverter. total of 3.44kw.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57820	18041-20000-16466	555 S FLOWER ST	90017	14	130-5A209  96	5151023400	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	PIN	34.05190831	-118.25695148	Tenant improvement to floors 12, 13, 19, 20, and 21 of (E) commercial highrise building.  Plan check for power and energy.  Building permit filed under 18016-10000-13444.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57821	14041-10000-34721	8556 S EMERSON AVE UNIT 1	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	02/10/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 1 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57822	19041-10000-13345	17312 W SUPERIOR ST	91325	12	201B133   435	2755008005	RA-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM			Reviewed by Supervisor	04/25/2019 12:00:00 AM	ADDRESS	34.24655	-118.51197	Installation of (3) ESS Tesla Powerwalls total of 40.5 kWh, interconect with Existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57823	20041-10000-12534	10853 W VANOWEN ST	91605	2	183B173   229	2466018045	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM			PC Info Complete	04/29/2020 12:00:00 AM	ADDRESS	34.19413	-118.36777	PLAN CHECK FOR TITLE 24 ONLY FOR - fire damaged repair of entire roof and portion of 2nd floor of existing storage bldg.  Tie in the 2nd foor & roof diaphragm & sub-diaphragms to CMU walls and add new accessible parking. - TOTAL AFFECTED AREA = 5743 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57824	12041-10000-18984	943 W STATLER ST	90731	15	024B197    56	7442003011	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	33.76399	-118.29909	Plan check for new roof mounted photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57825	12041-20001-27729	3636 W BEVERLY BLVD	90004	13	138B197   449	5501009024	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.07557	-118.28737	Changes made to approved set of plans for clouded delta 3 changes only.<<<<TI IN AN EXISTING 13 STORY TOWER. EXISTING SELF STORAGE AND OFFICE WITH A 700 SQ FT ADDITION.  UPGRADE LIGHTING AND PANELS. EPC IS FOR POWER & ENERGY.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57826	17041-10000-10768	4680 S LINCOLN BLVD	90292	11	105B153   147	4224014021	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	33.98105	-118.43929	PC for energy only, Outdoor/Indoor Title 24. Adding new lighting and power at McDondald's Restaurant. Area:4,598.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57827	17041-20001-46483	5012 N MAMMOTH AVE	91423	4	171B157  1013	2269002020	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.16154	-118.43229	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled batter backup system for SFD.5.2kW ungrounded system. (18) 325W pv modules. (1) 5kW Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57828	16041-20000-23187	515 S FLOWER ST 25th Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 only in existing office high-rise. Total area: 22,411 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57829	17041-20000-00689	16934 W PLUMMER ST	91343	12	198B133    79	2687001029	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.24279	-118.50135	pv1install roof mounted pv system sized 11.2kw interconnected with msp.Note: $0.00 permit fee due to Senate 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57830	13041-10000-23192	4462 W DON MIGUEL DR	90008	8	114B181   695	5027003002	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.00594	-118.35224	PV1 8.82KWdc 240V XFMR(-) INV. 2STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 36) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57831	16041-10000-15451	1150 S OLIVE ST 11TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR AN EXISTING OFFICE ON THE 11TH FLOOR OF AN EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 14493 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57832	17041-10001-23479	3321 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Closed	01/05/2023 12:00:00 AM	ADDRESS	34.0275	-118.3723	PC for PWR, scope include construction change to added fire pump, transformer. change to panels and feeders and adding new CKTS.Note. Applicant prefer original plan checker, Mehdi, to check the plan.Electrical permit for tower #17041-10000-21151Building permit #16010-10000-04628	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57833	15041-20001-36863	1238 W 50TH ST	90037	9	111B197  1136	5017010021	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	33.99767	-118.29731	This is PC only, changed module rooftop configuration. Online permit under 15041-90000-36863.(15) SW285 Mono(15) microinverter M250-60Standard plan is used.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57834	12041-20000-29553	13606 W ROSCOE BLVD	91402	6	192B157   710	2213021013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/07/2012 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.22145	-118.42935	NEW RETAIL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57835	13041-10000-05868	1110 S GLENVILLE DR	90035	5	132B169   510	4332002059	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.05675	-118.39261	FIRE ALARM SYSTEM FOR APARTMENT COMPLEX. TOTAL OF 93 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57836	18041-10000-14533	20539 W VENTURA BLVD	91364	3	171B109    50	2166033033	(Q)C2-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	33.9787	-118.31759	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57837	17041-20000-01439	3620 S MCCLINTOCK AVE sgm 529	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.0213	-118.28935	ti to an existing commercial office building non high rise.  adding new lighting new controls to existing panels.  plan cehck for energy only.  total square footage 658.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57838	10041-20000-09845	15031 W RINALDI ST canser-treatment	91345	7	213B145    64	2664022022	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1066.06	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	09/13/2010 12:00:00 AM	ADDRESS	34.27918	-118.46029	Equipment change out / upgrade for new linear accelerator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57839	13041-10000-32359	9164 W PICO BLVD	90035	5	132B169   891	4306004002	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.05507	-118.39143	TITLE 24 PART 6 ENERGY WORK; REMOVING (E) HID FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57840	14041-10000-02679	4299 S CRENSHAW BLVD	90008	8	114B185  1064	5024007023	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Info Complete	04/23/2014 12:00:00 AM	ADDRESS	34.00545	-118.33406	Resubmittal of plans due to expiration of plan check.  Customer has submitted original approved set as well as sheets modified to conform with current NEC cycle.  Original plan check submitted under 11041-10000-27336.  11041-10000-27336: (((Plan check power and energy for new 7-Eleven tenant in existing building. Main 1000A service approved under #13041-10000-16216	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57841	17041-20000-29331	931-933 N HIGHLAND AVE	90038	4	144B185  1043	5532012042	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM			PC Approved	08/17/2017 12:00:00 AM	ADDRESS	34.08802	-118.33877	Plan check for energy only. TI to existing school - (2) classrooms. New lighting - 1,018sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57842	12041-10000-19701	7247 N DARNOCH WAY	91307	3	186B089   773	2027020030	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.20207	-118.64533	New 9.36kw, rooftop mounted, photovoltaic system for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57843	18041-10000-04619	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.04337	-118.23442	PC for T24 only for new lights for office ti. Installing new lights, recetpaces and equipment. Total area 1305sqft. B# 17016-20000-36909.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57844	14041-20008-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM			PC Approved	06/06/2018 12:00:00 AM	ADDRESS	33.95713	-118.3847	05-10-2018 Changes to an permitted set of plans,  changes include revised emergency lightig source from battery to inverter system . All changes apply to delta 12 only. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57845	15041-10000-04561	7110 S MCKINLEY AVE	90001	9	102B205  1591	6007015022	M3-1, MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	33.97535	-118.26125	Title 24 plan check only.  Total area = 9,788 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57846	17041-20000-46643	3760 S STEWART AVE	90066	11	111B153   247	4246028024	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.00307	-118.43795	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. Existing solar pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57847	15041-10001-37840	462 E COMMERCIAL ST SERVICE-BLDG	90012	14	130-5A215  46	5173001905	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05309	-118.23584	PC only due to lost approved set.This is 5 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************ONE-STORY SERVICE BUILDINGSEE 15010-10000-01117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57848	15041-20001-33408	1418 S VAN NESS AVE	90019	10	129B189  1237	5073002011	[Q]R3-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.04	Electrical	Electrical	Apartment			10/08/2015 12:00:00 AM			PC Approved	11/20/2015 12:00:00 AM	ADDRESS	34.04567	-118.31555	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (18) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57849	15041-20000-01245	2024 N CUMMINGS LANE	90027	4	151-5A195 180	5589009033	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.10793	-118.30124	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(36) SUNPOWER SPR-E20 MODULES(2) SMA SB6000TL INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57850	14041-20001-15476	806 N KENMORE AVE	90029	13	141B197   111	5538014013	RD2-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.08615	-118.29688	Fee for expedite only.*****New roof mounted PV system with optimizers and transformerless inverter.  Total system size 9.52KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57851	15041-10000-05299	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	INSTALLATION IN EACH OF 4 ROOMS, UPS, PANELBOARDS AND CKTSPLAN CK IS FOR TITLE 24 IN ROOMS 7127;7128;7129;7130  TERMINAL 7	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57852	15041-20000-32034	12300 N SAN FERNANDO ROAD	91342	7	219B149   761	2507007001	R2-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Expired	10/24/2017 12:00:00 AM	ADDRESS	34.29442	-118.45204	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING STANDARD PLAN. TOTAL OF 25 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57853	18041-10000-10521	777 S FIGUEROA ST 31st &33rd-flrs	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	ALTERATIONS IN REST ROOMS ON 31ST AND AND33RD FLOORS OF OFFICE BUILDING PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57854	15041-20000-02919	11538 N SANTINI LANE	91326	12	213B109   363	2701067003	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.28151	-118.58797	PV1. Install roof mounted PV system sized 6.0 kW. Interconnected with main service panel.(33) Modules(1) 6.0 kW Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57855	16041-10000-39491	1145 E 11TH ST	90021	14	123A213   120	5132007042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.03147	-118.24568	Title 24 plan check.  Remove HID fixtures and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57856	19041-20002-50568	6014 N FAIR AVE	91606	2	177B173  1112	2337005024	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.17989	-118.37457	12-30-2019 Changes to an approved set of plan, Changes include revised feeder size from #3 AWG to #4 AWG conductor. All Changes has been clouded. Plan check onlyFess $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57857	19041-20000-48879	8701 N VINEVALLEY DR	91352	2	195B177   484	2404027022	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.22757	-118.35927	PV1.  Install 9.425 kW DC / 7.6 kW AC roof mounted grid tied PV system with 9.8 kWh energy storage system.  (29) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57858	17041-10000-00398	15715 W LASSEN ST	91343	12	201B141   175	2661029003	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.25025	-118.47449	PV, INSTALLATION OF 6.1 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(17) AC MODULES: SUNPOWER SPR-X22-360-C-AC. System equipped with rapid shut down by UL report  Refference # E479127.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57859	17041-10001-27221	510 N BONHILL ROAD	90049	11	135B141   234	4403019004	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	34.06798	-118.4812	Supplemental PC for PV expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57860	16041-10001-45835	2644 E ROSEVIEW AVE	90065	1	145-5A217  90	5453003054	RD3-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			Reviewed by Supervisor	01/23/2017 12:00:00 AM	ADDRESS	34.09342	-118.22769	FEE EXPEDITEPV2, PC FOR PV ROOF MOUNTED SYSTEM IN AN APARTMENT BUILDING. SYSTEM SIZE 3KW (AC) CENTRAL INVERTER WITH 8 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57861	16041-10000-42764	17324 W TRAMONTO DR 1-8-Bldg 5	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	12/07/2021 12:00:00 AM	ADDRESS	34.04158	-118.55502	Plan check for power and energy New appartment building 4 story 8 units (Type A) .  With 1 service 4,000A feeding all 9 buildings. Performance method is being use for Title 24. Total area: 14,623 sq ft.Note: This is 9 buildings submit  in 1 plan. 5 of  9  building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57862	13041-20000-14699	13273 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELING. TOTAL SYSTEM SIZE 3.2 KW USING 15 MODULES. ENPHASE MICROINVERTER M215 STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57863	16041-20000-27492	10830 N OWENSMOUTH AVE	91311	12	207B105    70	2722031008	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.26711	-118.60154	Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP. 6.72kW ungrounded system.(28) EnPhase M250 microinverters and (28) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57864	13041-20000-33752	11509 N LAUREL CANYON BLVD	91340	7	213B149   396	2613027019	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.27887	-118.45394	T24 FOR EXISTING CARLS JR. DOING OUTDOOR LED STRIP LIGHT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57865	11041-20000-27019	5700 W WILSHIRE BLVD Ste 510	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	03/14/2012 12:00:00 AM	ADDRESS	34.06218	-118.35303	T.I. For Suite 510.  Relocation of light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57866	16041-20000-20965	888 S FIGUEROA ST	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 3680.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57867	12041-10000-26789	3470 W WILSHIRE BLVD 200	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.06152	-118.3001	PLAN CHECK FOR ENERGY. 940 SF. CHANGE FROM OFFICE TO BAR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57868	18041-20000-34867	12217 W WILSHIRE BLVD	90025	11	126B145   243	4264026005	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Info Complete	09/12/2018 12:00:00 AM	ADDRESS	34.04331	-118.46874	Plan check for Title 24 Energy only in existing restaurant T.I. Total area: 2,911 sq ftB#18016-20000-08824	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57869	17041-10000-23460	6401 W WESTCHESTER PKWY	90045	11	096B165   959	4122022928	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	33.95473	-118.39853	PC FOR POWER ONLY. TEMPORARY POWER FOR 7 TRAILERS AT LAX. SCOPE INCLUDES ADDING SEVEN 100A PANELS AND ONE 100A METER SECTION TO AN EXISTING DISTRIBUTION BOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57870	14041-10000-08145	12665 W VILLAGE LANE block 5	90094	11	102B161  1257	4211034036	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/26/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	33.97786	-118.41484	FA FOR PLAYA VISTA II BLOCK 5. 4 buildings but only 1 FACP. Fee arrangment to be verified by plan checker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57871	16041-30000-23865	600 W 7TH ST Suite 120	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.04728	-118.25685	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 980 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57872	16041-30001-39954	700 W 7TH ST G80, G230,-G420, G630	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Issued	02/23/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	02/23/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance forms.*****Previous Work Description*****PC FOR TITLE-24. ENERGY ONLY. SCOPE INCLUDES  4 TENENAT SPACES. TOTAL AFFECTED AREA OF 6303 SQ.FT. BLDG APP# 16016-10000-26529: Suites G80, G230, G420, & G630.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57873	15041-20002-13675	6250 N TOPANGA CANYON BLVD BldgF#1530	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	09/02/2015 Changes to an approved set of plans. Changes include the replacement of a split bus panel with (2) panels, revised home-runs, and the relocation of the transformer. All changes have been clouded and marked as Delta 3.*****Previous Work Description*****09/01/2015 Changes to an approved set of plans. Changes include the relocation of outlets in the Open Area.*****Previous Work Description*****Plan check for 1st time tenant at Westfield Village at Tapanga(Bldg F #1530) for Credit Union. Total area: 2,000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57874	13041-20000-03640	2323 S HOOVER ST	90007	8	124-5A201 259	5055020001	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			Reviewed by Supervisor	03/27/2013 12:00:00 AM	ADDRESS	34.03453	-118.28423	Plan check for power and energy. 1st time tenant. Cast Iron Restaurant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57875	12041-10000-20076	325 W ADAMS BLVD	90007	9	121-5A205 132	5126018032	(T)(Q)C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.02712	-118.27319	Plan check power and energy first time tenant in mixed used building. Cafe Lorenzo.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57876	18041-20001-45062	1617 N CASALE ROAD	90272	11	132B133    39	4425001012	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM			PC Approved	12/04/2018 12:00:00 AM	ADDRESS	34.06141	-118.50295	Expedite fee.PV1.   Installation of a 20.5 kW roof mounted grid tied PV system.  (52) modules with microinverters.  Removal of (E) PV system.  Derating of main service disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57877	16041-10000-19286	1929 S HAUSER BLVD	90016	10	126B177  1090	5064010024	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Expired	07/05/2018 12:00:00 AM	ADDRESS	34.03996	-118.36028	PV1, rooftop solar installation on SFD, 3.8 kW AC system.  (12) HiS-M260     (1) fronius primo 3.8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57878	18041-10000-01004	18716 W OXNARD ST	91356	3	177B121   591	2156019046	(Q)MR1-1, (Q)P-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.18002	-118.54138	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 16990 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57879	15041-20000-10548	10000 N ALDEA AVE	91325	12	204B133   633	2694007008	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.25248	-118.5088	PV1 SFD. TOTAL SYSTEM SIZE 4.8KW AC USING NONSTANDARD PLAN. INSTALLING MICROINVERTER SYSTEM USING ENPHASE M250. TOTAL OF 20 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57880	18041-20000-35924	19209 W KNAPP ST	91324	12	198B121   541	2762036024	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.23831	-118.55067	Plan check for a PV 1 roof-mounted PV system. System size is 14.4 kWdc/13.1 kWac and consists of (40) modules, (40) micro-inverters, (1) load centers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57881	11041-10000-11368	444 S FLOWER ST 7th & 8th-floors	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Approved	06/02/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	alterations in the elevator lobbys on the 7th & 8th floors- plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57882	13041-10002-23043	14615 W OXNARD ST	91411	6	177A151    96	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.17955	-118.45137	PC FOR Changes to approved set UNDER DELTA 8SCOPE INCLUDES : SERIES RATING OF PANELS WITH MAIN DISTRIBUTION BOARD. SIEMENS COMBINATION FD6-A WITH BL & JXD2-A WITH BLH CHANGES ARE CLOUDED UNDER DELTA 8	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57883	19041-20000-16560	337 N KINGS ROAD pv1	90048	5	138B173   258	5514010018	R1V3-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.07711	-118.37226	pv1install roof mounted pv system sized 7.6KW AC interonnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57884	17041-20001-38126	11846 W SATICOY ST	91605	2	186B169   260	2317009003	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.20832	-118.3919	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.Total system size: 11.52kW ungrounded.(36) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57885	12041-10000-27245	7271 N DARNOCH WAY	91307	3	186B089   708	2027020027	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.2025	-118.64518	PV1. 6.37 KW ROOF MOUNTED SOLAR PV ELECTRIC SYSTEM INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57886	19041-10000-48854	2635 N HYPERION AVE	90027	4	150A205    50	5433025013	C4-1D	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	04/05/2022 12:00:00 AM	ADDRESS	34.10663	-118.27256	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57887	16041-20000-25784	941 E 35TH ST	90011	9	115-5A209  87	5114016001	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Expired	10/05/2018 12:00:00 AM	ADDRESS	34.01191	-118.25916	Plan check for power only in USC HOFFAN COANTRACT RESEARCH BUILDING install Transformer 150 KVA 1 600A panel and 3 subpanel with no load on the panel boards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57888	18041-10000-28159	5639 E HUNTINGTON DR NORTH 1-13	90032	14	147A239   188	5309027016	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Apartment			07/26/2018 12:00:00 AM	05/07/2020 12:00:00 AM		Permit Finaled	11/15/2022 12:00:00 AM	ADDRESS	34.09625	-118.15699	PLAN CHECK FOR POWER AND ENERGY FOR (N) 13 units 2-story apartment building over 1-story basement garage.NEW SERVICE RATED AT 600A 120/240V 1PH, 3W.  WITH 3 TYPICAL UNITS. TOTAL AFFECTED AREA  11045 SQ.FTB#15010-10000-02318	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57889	16041-10000-08301	300 S SANTA FE AVE # I	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	FIRST TENANT IN NEW COMMERCIAL SPACE -NAIL SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57890	16041-10000-00862	12700 W MILLENNIUM # 53	90094	11	102B161  1280	4211037036	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.5KW INTERCONNECTED WITH MSP.ADDITIONAL CIRCUIT FOR AC MODULE SUPERVISOR.ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO UNITS #49, 50, 51, 52 AND 53.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57891	16041-10000-09714	450 S WESTERN AVE # 213	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM EXISTING RETAIL TO BANK. SCOPE INCLUDES NEW LIGHTS AND THREE NEW PANELS. TOTAL AFFECTED AREA IS 1005 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57892	16041-10000-25617	17250 W SATICOY ST	91406	6	186B133   238	2203017042	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.20822	-118.50895	Full Plan TI to existing Ralphs commercial building grocerystore. Existing main service, adding 2 new panels and tranformers. Adding new load to existing panels. Newly connected load is greater than 400 amps. Total sqft = 2850	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57893	17041-10000-40288	821 N CHESTNUT AVE	90042	14	154-5A235 115	5493036002	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.11816	-118.17088	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 3.0KVA CONSISTING OF 1 CENTRAL INVERTER(SOLAREDGE SE3000H-US) WITH 10 MODULES AND POWER OPTIMIZERS(P320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57894	16041-20000-34597	2915 N KNOX AVE	90039	13	148-5A213 650	5442018014	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.10318	-118.24338	Renovation of (E) building - core and shell drawings.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57895	19041-20001-32382	6400 N LAUREL CANYON BLVD SUITE 400	91606	5	180B165   677	2322007057	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	34.18693	-118.3963	12/19/19CHANGES TO APPROVED SET DELTA 1 ONLY. CHANGES TO LIGHTS AND RECEPTACLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57896	19041-10000-25046	6616 N YOLANDA AVE	91335	3	180B121   298	2126033002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.19077	-118.54026	[e-plan] PV1. PLAN CHECK FOR ROOF MOUNTED SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 19 MODULES USING P370 OPTIMIZERS AND 1 ESS(TESLA POWER WALL) CONNECTED TO 200A SERVICE WITH 225A SERVICE PANEL BOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57897	13041-10000-19741	23752 W LADRILLO ST	91367	3	171B093   523	2047004016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.16417	-118.64296	Plan check for 14KW roof mounted photovoltaic system with FRONIUS IG Plus 10.0  56 MODULES : TRINA SOLAR # TSM-250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57898	12041-10000-21027	8639 W LE BERTHON ST	91040	2	207B189    15	2551043029	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.2681	-118.32135	Plan check roof mounted 4.5KW photovoltaic system using SunPower transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57899	17041-20000-42258	555 W 5TH ST 1ST FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	TENANT IMPROVEMENT OF WEWORK OFFICE SPACE (CHANGE OF USE TO OFFICE AND RESTAURANT), PC FOR POWER &  ENERGY.  CONNECTED LOAD > 400AMP. TOTAL AREA: 8681SQ FT.B # 17016-10000-11625	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57900	16041-20001-05644	16101 W BLACKHAWK ST	91344	12	204B141   199	2668020010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	34.2584	-118.48286	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 6.0kW with 20 modules and 1 inverter(5.0kW) and 5 microinverter. System mix with microinverters and central inverter.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57901	16041-10000-42627	13233 W BOMBAY ST	91342	7	225B157   468	2512020057	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.31364	-118.42109	ROOFTOP SOLARPC FOR PV SYSTEM TOTAL OF 3.8KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57902	11041-10000-08411	8275 W BEVERLY BLVD	90048	5	138B173   394	5514009051	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	10/05/2011 12:00:00 AM	ADDRESS	34.07623	-118.36982	NEW FIRE ALARM SYSTEM IN EXISTING OFFICE BUILDING.  OTC PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57903	15041-20000-01340	21040 W CALIFA ST SUITE A	91367	3	174B105     8	2149002021	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.17715	-118.59163	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE OF FROM OFFICE TO DIALYSIS CLINIC. PC FOR MEDICAL PER ARTICLE 517. NO CRITICAL CARE AREAS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57904	14041-10000-14621	1229-1233 S WESTGATE AVE	90025	11	129B145   961	4263007082	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Apartment			06/02/2014 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.0465	-118.4629	PC FOR POWER AND ENERGY. NEW APARTMENT BUILDING  WITH 57 UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57905	19041-30000-39523	350 S GRAND AVE 3050	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	08/26/2020 12:00:00 AM	ADDRESS	34.05173	-118.2522	PLAN CHECK FOR ENERGY ONLY, TI TO AN EXISTING SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4695.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57906	19041-20000-27869	23417 W BALMORAL LANE	91307	12	183B093   218	2028019011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.19866	-118.63675	Plan check for PV roof monted and energy stroage system, PV system size: 8.19 KW with 26 PV Modules and 1 inverter(7.6kW), and 1 Tesla Power Wall 2.0 13.5kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57907	18041-20000-42036	5808 W SUNSET BLVD 5TH FLOOR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check for Title 24 only in existing high-rise space office T.I. partial 5th Floor. Total area: 11688 sq ft. B#18016-10000-34019	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57908	13041-10000-27681	170 N GLENDALE BLVD	90026	1	135A209   230	5160013013	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Info Complete	11/05/2013 12:00:00 AM	ADDRESS	34.0639	-118.25974	PV2. ROOF MOUNTED 6.0KW DC PHOTOVOLTAIC SYSTEM ON STEEL CANOPIES ATTACHED TO COMMERCIAL BUILDINGS. (170 AND 180 GLENDALE AVE. USING LUMOS LSX 250 MODULESAND (1) SMA SUNNY BOY 4000US. PERMIT BASED ON SUPPLEMENTAL P.C #13041-10002-27681, WHERE MODULES WERE REDUCED FROM 24 TO 17 AND INVERTER DOWNSIZED FROM 5 kW TO 4 kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57909	16041-10002-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			06/01/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	SEE APPLICATION NOTES***********PC FOR  CHANGES TO APPROVED SET UNDER DELTA 7 & 9 .SCOPE INCLUDES CHANGES TO LIGHTS  AND T-24 IN ALL FLOORS. ADDITIONAL AREA HAS BEEN ADDED FOR AROUND 3000SQ.FT FROM LAST APPROVED SET.  (((FULL PC FOR POWER AND ENERGY  FOR A NEW 7 STORY MIXED USE BLDG.:  169 UNIT APARTMENT WITH RETAIL AND PARKING. SCOPE INCLUDES A NEW 4000A 277/480V 3 PHASE, 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. THERE ARE 11 TYPES OF APARTMENT UNIT PANELS. TOTAL AFFECTED AREA IS 160530 SQ. FT. B#16010-10000-03070Fire alarm modification was filed with the department 4/5/2017.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57910	13041-20000-18718	11175 W SANTA MONICA BLVD	90025	5	129B149   297	4324035029	M1-2	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.04739	-118.44609	FIRE ALARM SYSTEM TO BE RENOVATED. NEW DEVICES, REPLACE DEVICES, AND REPLACE CONTROL PANEL. PART OF OFFICES BUILDING. HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57911	18041-10003-02129	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	PLAN CHECK ONLY. DELTA ASI 008 CHANGES TO AN APPROVED SET. CIRCUIT MODIFICATION AND LOAD UPDATES ON PANEL 1LCB2. NO NEW CIRCUITS ADDEDPLAN CHECK PER APPLICANT REQUEST. Original Scope: (PC for power and energy for terminal 5 of LAX. Scope includes adding new panels, lights, receptacels, equipment to kiosk/ticketing, offices, common areas and outdoor.Total area is 29666sqft. B# 17016-10000-33718Tenant Improvement to LAX Terminal 5 to include (1) installation of new storefront glazing system, (2) new public restrooms, (3) new AA and OAL offices on Arrival Level, (4) linear ticket counters at Departure Level, (5) new medical offices on Mezzanine Level, and (6) alteration and addition to existing structural.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57912	14041-20000-07212	15157 W GAULT ST	91405	6	183B145   804	2220001029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.19949	-118.46381	Roof mounted PV system with 4.25KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57913	17041-20000-33371	757 S ALAMEDA ST PHASE I	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.0318	-118.23916	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE OF EXISTING TYPE IA COMMERCIAL BUILDING - CORE AND SHELL.  PHASE I OF CORE AND SHELL DISTRIBUTION BASIC POWER AND LIGHTING.   BUILDING PERMIT UNDER 17016-10000-20345.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57914	15041-10000-34366	639 N SIERRA BONITA AVE	90036	5	141B177   707	5526016004	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.08304	-118.35439	PV1, INSTALL NEW9.54 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY.(36) MODOULES: KYOCERA KU2656ZPA(1) INVERTER: FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57915	10041-20000-20795	11541 N BLUCHER ST bldg5	91344	12	213B145    79	2605002012	QC1-1VL, QP-1VL	North Valley	Granada Hills - Knollwood		YES	1092.00	Electrical	Electrical	Apartment			10/19/2010 12:00:00 AM			PC Approved	11/08/2010 12:00:00 AM	PIN	34.27943684	-118.47043731	Permit expired (BLDG. 5).  EPC for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57916	16041-20001-17387	330 S BERENDO ST	90020	10			R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.06809	-118.29397	EXPEDITE PER APPLICANT REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 48KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57917	15041-10000-23369	24500 W PAT PL	91367	3	177B085   536	2032014002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2015 12:00:00 AM			PC Approved	07/22/2015 12:00:00 AM	ADDRESS	34.17822	-118.65852	CHANGES TO AN APPROVED SET OF PLANS.  CHANGE INVERTER FROM ABB 5000 TO ABB 3.8 KW SIZE AND REDUCTION OF ONE MODULE.REFERENCE APPLICATION NUMBER 15041-10000-16492 FOR MASTER PERMIT.THIS IS PLAN CHECK ONLY.PV1, INSTALL 14.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(43) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-3.8 AND PVI-3.8 AND PVI 5000-OUTD -US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57918	19041-10000-03083	20441 W ESMERELDA LANE	91326	12	216B109   262	2701082077	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.29114	-118.57954	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.60KWac.(24)OPTIMIZERS-PANASONIC VBHN330SA16(24)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE7600H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57919	19041-20000-08725	6701 S CENTER DR WEST 5th flr-restroom	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	ti to an existing commercial building.  adding new lighting new control to existing panels.  plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57920	11041-10002-13923	3377 W OLYMPIC BLVD	90019	4	129B193   285	5081033011	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			PC Approved	08/30/2012 12:00:00 AM	ADDRESS	34.0528	-118.31175	REVISIONS TO APPROVED SET OF PLANS-RELOCATE THE SWITCHBOARD INSIDE THE BUILDING AND CHANGE LIGHTING TO TRACK LIGHTING.tHESE ARE AS BUILT SET OF PLANS.Existing restaurant T.I.  Upgrading service from 400 Amps to 600 Amps.  Plan check is for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57921	10041-10000-08165	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	08/16/2010 12:00:00 AM	PIN	33.94094587	-118.40577128	TI IN TOM BRADLEY TERMINAL (GUCCI SHOP). PC FOR T24 AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57922	19041-30000-17556	4322 N GENTRY AVE	91604	2	165B165   573	2368009085	[Q]RD1.5-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Apartment			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	06/05/2020 12:00:00 AM	ADDRESS	34.14929	-118.39304	Plan check for a fire alarm system for a 2-story, 10-unit apartment building. Fire alarm consists of (1) FACP and (52) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57923	13041-10000-36176	1238 S WALL ST	90015	14	124-5A209 259	5145026037	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.0341	-118.25591	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57924	12041-20000-10791	3183 W WILSHIRE BLVD STE 195	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20, 2122.03	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.06196	-118.29111	Change of use from retail to restaurant.  Install new panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57925	10041-20000-11061	11100 W SANTA MONICA BLVD #380	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	06/10/2010 12:00:00 AM		Permit Finaled	07/12/2010 12:00:00 AM	ADDRESS	34.04726	-118.44465	s.380 office t.i.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57926	14041-10000-08527	9840 N WISH AVE	91325	12	201B133   188	2692014020	RA-1-H	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.24953	-118.50776	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 14KWAC., LOW FEES DUE TO 2012 SENATE BILL NO. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57927	14041-10000-07875	11216 W EXPOSITION BOULEVARD S/R	90064	5	123B153   276	4256011902	[Q]PF-1XL	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	PIN	34.03456305	-118.43511483	NEW FIRE ALARM SYSTEM FOR PARKING STRUCTURE. 12 devices and 1 panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57928	13041-20001-17880	11854 W OLYMPIC BLVD	90064	11	123B149   529	4259024004	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Issued	03/04/2014 12:00:00 AM	ADDRESS	34.03259	-118.45147	Change to lighting and receptacle loads from previuosly approved set. changes clouded delta 4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57929	18041-20000-18852	19500 W PLUMMER ST STE A2	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.2426	-118.55846	Change of use from retail to children's gym.  Assembly occupancy over 100 occupants.  Plan check for power and energy.Building permit under 18016-10000-13882.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57930	12041-10000-03580	3430 S SEPULVEDA BLVD 1-8	90034	5	117B157    27	4251028032	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Apartment			02/16/2012 12:00:00 AM	02/16/2012 12:00:00 AM		Permit Finaled	02/27/2012 12:00:00 AM	ADDRESS	34.02048	-118.42295	installation of new panel and one smoke detector.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57931	15041-10000-33327	21700 W OXNARD ST SUITE-#200	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.17901	-118.60179	T-24, TI ON THE 2ND FLOOR TO AN (E) HIGH RISE OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 19680.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57932	13041-10000-24720	17224 W BULLOCK ST	91316	5	177B133    49	2255007018	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	10/19/2013 12:00:00 AM	ADDRESS	34.17969	-118.50854	PV1.  Instal 7.84 kW DC roof-mounted solar array of 32 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57933	16041-10000-41501	1150 S OLIVE ST SUITE 1350	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.03962	-118.26181	PC FOR TITLE 24 ENERGY ONLY SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.TOTAL AFFECTED AREA 3680 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57934	10041-20002-19833	8719 N BRADLEY AVE	91352	6	195B173   541	2408023017	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM			PC Approved	02/24/2011 12:00:00 AM	ADDRESS	34.22785	-118.37426	Supplemental plan check on revision to approved plans. Site plan revise to indicate property line.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57935	16041-10000-14196	15500 N STEPHEN S WISE DR	90077	5	159B145   579	4378001008	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.12835	-118.46993	Plan check for power and Title 24.  Total area = 10,545 sq. ft.RENOVATION/ADDITION TO (E) SANCTUARY SPACE INCLUDING (N) GYM, RENOVATED OFFICES, RESTROOMS. ASSEMBLY OCCUPANCY.  NEW 400 PANEL TAPPED FROM MAIN DISTRIBUTION SECTION WHICH FEEDS 4 SUBPANELS AND ASSOCIATED LIGHTING AND PLUG LOADS.Building permit #16014-10000-01040	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57936	14041-10000-16137	1575 N GOWER ST	90028	13	148-5A189 331	5546026024	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Closed	08/02/2018 12:00:00 AM	ADDRESS	34.09907	-118.32257	NEW FIRE ALARM SYSTEM.406 NEW DEVICES. 1 CONTROL PANEL. 5 LEVEL PARKING GARAZHE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57937	13041-10000-20786	1530 N HILLHURST AVE 1st & 2nd	90027	4	147B197   561	5542006022	[Q]C2-2D	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.09931	-118.28724	TI for clinic (healthcare faciilty) on 1st and 2nd floors. Lobbies, check-in, nursing, exam rooms, and relocate rest rooms	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57938	19041-20000-22442	1437 N KINGS ROAD	90069	4	147B173   542	5555013028	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Issued	07/08/2019 12:00:00 AM	ADDRESS	34.09628	-118.37285	Plan check for PV ground mounted system, PV system size: 14.625KW DC, 14.18KW AC with 45 PV Modules and 45 microinverters connected to 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57939	17041-10000-07751	2619 N FIGUEROA ST	90065	1	142-5A219 129	5446010023	UC(CA)	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.08438	-118.22201	PC for title 24 only, outdoor. Replacing existing fixtures and replacing them with new LEDS for outdoor use. Area: 41,500.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57940	13041-20000-35634	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			Reviewed by Supervisor	01/03/2014 12:00:00 AM	ADDRESS	33.9867	-118.44159	PLAN CHECK FOR POWER FOR FIRST TIME TENANT. THIS PLAN CHECK COVERS PANELS AND PROJECT LOAD CALC ONLY. TENANT MOVING IS REQUIRED TO GO TO PLAN CHECK FOR A FULL PLAN REVIEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57941	13041-10000-00262	24911 S WESTERN AVE	90717	15	039B193   649	7372017031	[Q]C2-1VL, [Q]P-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			01/04/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	33.79838	-118.30784	scope of work pertaining to hvac system only. removal of existing (1) 40 tons and install new 8 RTUs . all lighting and other power distribution will be under sparate submittal.This area was a grocery store now will be a retail store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57942	17041-20001-24347	7061 W FOOTHILL BLVD	91042	7	202-5A201 456	2568016050	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.20	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.24814	-118.28543	Expedite fee per applicant requst.  (((PV2.  Install 50.3 kW roof mounted grid tied PV system.  Feed-in-tariff project.  (168) modules with (2) SolarEdge inverters)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57943	17041-10000-16471	4143 S CLOVERDALE AVE	90008	10	117B177   540	5029040011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.01312	-118.36599	PC FOR ROOF MOUNTED PV SYSTEM.SYSTEM SIZE 7.6KWACSCOPE INCLUDES 27 MOUDLUES WITH OPTIMIZERS ONE SINGLE INVERTER SOLAR EDGE 7600.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57944	15041-20000-05077	7943 N MOORCROFT AVE PV1	91304	3	189B101   321	2012029031	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.21493	-118.61173	CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 5KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57945	19041-20000-36632	6330 N RANDI AVE	91367	3	177B101    17	2146001024	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	06/02/2022 12:00:00 AM	ADDRESS	34.18503	-118.61009	PV2.  Plan check for PV roof mounted system, System size: 30.015KW DC, 26.7KW AC with 69 PV Modules and 2 inverter(14.4KW )Note: This is 12 buildings on 1 Plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57946	17041-10000-02801	3655 W PICO BLVD	90019	10	129B189   950	5081014025	C4-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.04743	-118.32085	T-24, PC FOR ENERGY OF ENERGY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 14900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57947	18041-10000-10862	8065 W 3RD ST	90048	5	138B177   731	5511022032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.07221	-118.36535	PC T24 only for restuarnt TI for (E) restuarant. Installing new lights, receptacles and equipment. Total area is 1080sqft. B#18016-10000-03358.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57948	19041-10000-19713	5975 N SHOUP AVE	91367	3	177B101   160	2040041008	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	11/18/2020 12:00:00 AM	ADDRESS	34.17892	-118.61491	FULL PLAN CHECK FOR SCHOOL TENANT IMPROVEMENT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 9100 SQ.FTBUILDING # 62-5B#19016-10000-15464	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57949	17041-10000-43033	6576 W QUINTON LANE	91042	7	201A203    42	2570019014	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.24723	-118.27547	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.8KWdc / 5.0KWac.(20)MODULES-SOLARWORLD 290(20)OPTIMIZER-P320(1)INVERTER-SOLAREDGE 5000H(240)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57950	19041-20000-44944	4619 N NAGLE AVE	91423	4	168B157   699	2360017034	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.15456	-118.42385	PV1 PLAN CHECK FOR NEW 4.95 KW DC/4.207 KW AC PV SYSTEM. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH OPTIMIZERS, A 5 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57951	12041-20000-18332	707 W WILSHIRE BLVD 29TH FLR.	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM			Corrections Issued	08/06/2012 12:00:00 AM	ADDRESS	34.04893	-118.2572	T.I. to a high rise building on the entire 29th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57952	10041-10000-14906	114 S CENTRAL AVE	90012	9	129A215    84	5161018021	[Q]C2-3D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.0487	-118.23901	Ti in an exixting restaurant. Plan check is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57953	14041-20000-34941	1327 N MCCADDEN PL	90028	4	147A185   330	5547033020	RD1.5-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.09513	-118.33758	PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.5 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (18) SUNMODULE PLUS SW275(18) EMPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57954	19041-10000-36995	755 S LOS ANGELES ST 4th floor	90014	14	127-5A211 230	5145001013	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	07/19/2021 12:00:00 AM	ADDRESS	34.04231	-118.25201	FULL PC FOR A FIRST TIME TENNAT IN THE 4TH FLOOR OF AN EXISTING CORN AND SHELL SPACE, THE CORN AND SHELL IS APPROVED UNDER 18041-10000-20031. SCOPE OF WORK INCLUDES FOUR NEW SUBPANELS, AND A NEW TRANSFORMER. TOTAL AFFECTED AREA IS 13,418 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57955	14041-10000-22126	13361 N GLENOAKS BLVD	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Public Safety Only			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.3146	-118.45921	Temporary installation of a fire warning system with central station monitoring for modular buildings which are used temporarilyas class rooms until school buidings can be constructed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57956	19041-20001-25634	915 W WILSHIRE BLVD 7TH FL-8TH FL	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.05069	-118.2599	10/29/19CHANGES TO APPROVED SET CHANGES TO DAYLIGHT SENSORS.<<<Tenant improvement on 7th and 8th floor of existing office high-rise building, newly connected load in excess of 400A. Total area: 35,420 sq ft. B#19016-100000-17777>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57957	16041-10000-01928	3621 S VIRGINIA ROAD	90016	10	120B185  1334	5046020005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.02233	-118.33939	PV1 roof mounted solar installation to a single family home. inverter rating: 3.8 kw. (15) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57958	19041-10000-24585	100 S GRAND AVE Tower #2-Residentia	90012	14	132A211    94	5149021***	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	34.05536	-118.24876	Full plan check for a brand new high rise 42-floor 436-unit  residential building (Tower #2) sharing a common parking at lower floor/underground with two other buildings (a 6th floor common podium and a 24-floor 308-hotel unit  buidling (Tower # 1)). Scope of tower # 2 includes a medium voltage 5kv 1200A service suppling tower #1 and tower #2. Note Tower# 1 and Podium building will be under a seperated applications.  Most of  title-24 energy calculation is under the application of podium building. All 3 application is under 1 set of plan.Related building application including: 17010-10000-01468                                                                       17010-10008-01468  (((PROPOSED MIXED USE HIGHRISE BUILDING CONSISTING OF 2 TOWERS OVER PARKING. 20 STORY HOTEL AND A 39 STORY APARTMENT BUILDING WHICH INCLUDES  **** AFFORDABLE UNITS. THE COMMERCIAL SPACES WILL BE APPROVED AS A CORE AND SHELL, THE HOTEL ROOMS WILL BE REVIEWED AND APPROVED UNDER THE 10008 PERMIT. THE TENANT IMPROVEMENTS TO BE APPROVED UNDER SEPARATE PLAN CHECK/PERMIT.STEEL STAIRS AND RAILS, CURTAIN WALLS- ALL DOORS AND WINDOWS/STORE FRONTS, GLASS COVERED STRUCTURES ARE DEFERRED STRUCTURALLYVERIFY THAT THE SUSMP CLEARANCE OBTAINED)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57959	12041-10000-05968	2256 S FIGUEROA ST	90007	9	123A205    92	5126006016	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Apartment			03/15/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	09/10/2013 12:00:00 AM	ADDRESS	34.03092	-118.27347	cHANGE OF USE , ADAPTIVE REUSE, 3 STORY, WORK IS ON PART OF THE 1ST FLOOR, 15 UNITS. NO TITLE 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57960	15041-10000-03206	724 S SPRING ST Unit 202-204	90014	14	127-5A211 131	5144015041	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.04384	-118.25268	TENANT IMPROVEMENT/CHANGE OF USE FROM OFFICE TO DANCE STUDIO IN A COMMERCIAL HIGH RISE BUILDING. TOTAL AREA 3188 SQ FT.  PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57961	17041-20001-42743	8815 N QUAKERTOWN AVE	91324	12	195B113   263	2782032013	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.23055	-118.56991	expeditepv1install roof mounted pv system sized 6kw interconnected  with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57962	09041-10004-24226	13488 W MAXELLA AVE	90292		105B153    77	4212004014	[Q]M1-1, [T][Q]RAS4-1		Palms - Mar Vista - Del Rey	Del Rey			Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	33.98592	-118.44252	<<<<MODIFICATION TO APPROVED SET OF PLANS>>>New 244 apartment building in methane zone.  Variance was filed to separate the the Fire Alarm plans and approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57963	19041-20000-05885	7101 W FOOTHILL BLVD	91042	7	202-5A201 451	2568014029	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	12/14/2020 12:00:00 AM		Permit Finaled	08/03/2021 12:00:00 AM	ADDRESS	34.2482	-118.28609	PC FOR INSTALLATION OF  A NEW CARWASH BEHIND A EXISTING 76 GAS STATION. SCOPE OF WORK INCLUDES NEW 600A SERVICE AND SWITCHBOARD, (1) NEW 200A PANEL, (1) NEW 100+ KVA CAR WASH MCC, AND (1) NEW 45KVA XFMR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
57964	13041-20000-19498	12037 W HART ST	91605	2	183B165   234	2321008025	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Apartment			07/23/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.19768	-118.39551	NEW 4 STORY APARTMENT WITH 1 SUB TERRANEAN GARAGE. 1200A SERVICE. FIre alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57965	19041-10001-03889	3387-3389 N EAGLE ROCK BLVD	90065	1	153A215   110	5457024001	R3-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.11443	-118.23648	PLAN CHECK ONLY. DELTA 1 CHANGES TO AN APPROVED SET. CHANGES TO THE SERVICE DROP LOCATION AND NUMBER OF SERVICE FEEDERS. COUNDUITS ARE AT 1/2' MINIMUM ABOVE ROOF.Original Scope:Service upgrade to 600 Amp in a mixed use building / 2 unit Apt & future commercial space. Plan Check for power & energy. Building Permit: 18016-10000-01325	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57966	15041-20000-22576	15207 FRED WAY	91405	6	186B145  1131		(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	PIN	34.20923851	-118.46436556	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57967	19041-20000-36727	11829 W NORFIELD CT	90077	5	150B141    84	4377046013	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	02/22/2020 12:00:00 AM	ADDRESS	34.10935	-118.477	$0 PERMIT FEE DUE TO SB1222 AND AB1414PLAN CHECK FOR NEW ROOF PV SYSTEM AND ENERGY STORAGE ON EXISTING SFD. PV SYSTEM SIZE IS 12.2 KW DC/15.2KW AC. BATTTERY SYSTEM SIZE IS 39.2 KWH. SCOPE OF WORK CONSISTS OF (40) PV MODULES WITH OPTIMIZERS, (2) 7.6 KW INVERTERS, A COMBINER PANEL, (2) LOAD PANELS, (2) 5KW AUTO TRANSFORMERS, AND (4) 9.8 KWH BATTERIES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57968	14041-10000-32456	368 E IMPERIAL HWY	90061	15	087A207   299	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	33.93087	-118.26711	Per�Senate�Bill�No.1222, Fee cap reached, thus fee is $0.PV2, INSTALL  15.68 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMERCIAL  BUILDING. INTERCONNECT WITH MAIN SERVICE PANEL. 6 STRINGS.(2) INVERTERS:  DELTA-SOLIVIA 7.6TL (56) MODULES: LDK SOLAR LDK-280P-24	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57969	15041-10000-24665	1633 N LA BREA AVE 1-180	90046	4	147B181  1177	5548008***	C4-1VL-SN, R4-1VL	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.10058	-118.34527	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT RETAIL STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57970	14041-10000-33857	907 E 3RD ST	90012	14	129A215   266	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	PIN	34.0461867	-118.23487077	Plan check for power only. Any future improvements or buildouts to have separate permits. Scope of project includes Removal of (E) distribution equipment and installation of New service and distribution equipment: 1 for 1 1200A 3p3w service replacement (MSB); Transformers (T-A,B,C,D,E); distribution board (LA1), panels  (HA-3,4,5,6) and underground conduit stub-outs to be installed. No loads in scope of this phase of project except Temp power circuits for construction.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57971	18041-10000-08793	4708 W FOUNTAIN AVE	90029	13	147B197  1135	5540017010	C2-CSA1	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM			Reviewed by Supervisor	04/11/2018 12:00:00 AM	ADDRESS	34.09537	-118.29201	PC FOR SHELL WORK  TO EXISTING COMMERCIAL BUILDING DUE TO FIRE DAMAGE.  SCOPE INCLUDES SERVICE UPGRADE AT 1200A 120/208V 3PH WITH NEW PANELS FOR TENANTS AND HVAC EQUIPMENT ONLY TO SOME TENANTS. ONLY EXTIRIOR LIGHTS. TOTAL AFFECTED AREA 4463 SQ.FT B#17016-30000-36917	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57972	13041-20000-13650	5115 W SUNSET BLVD	90027	13	147A195    66	5544014025	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.09829	-118.30109	Plan check for energy only. Tennis court and accessory building. Sunset Padel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57973	17041-10000-43681	1333 W TEMPLE ST	90026	1	136-5A209 262	5160005001	CW	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM			PC Info Complete	12/05/2017 12:00:00 AM	ADDRESS	34.06719	-118.25558	T-24, PC FOR ENERGY ONLY. T.I TO (E) PHOTO STUDIO. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4590 SQ. FT. B#17016-10000-26061	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57974	13041-20000-30089	7813 S ALVERSTONE AVE	90045	11	099B165   199	4109004012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	33.97029	-118.39738	PV1 MICROINVERTER NONSTANDARD PLAN. TOTAL SYSTEM SIZE 4.53KWAC. 20 MODULES WITH MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57975	15041-10000-18591	614 E TERMINAL WAY Second-Mar Bldg	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			06/15/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	33.74201	-118.26431	New fire warning system for Second Marine Building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57976	15041-20001-14826	2029 S CENTURY PARK EAST Suite 500	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			Ready to Issue	08/06/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	Changes to an approved set of plans. Reducing the scope of work. Total area: 2,383 sq ft.Original:Plan check for title  24 only T.I. for for office CAA Crative Artist Agency.  Total area: 5,034 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57977	10041-10000-03931	13067 W BLUFF CREEK DR	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/25/2010 12:00:00 AM	ADDRESS	33.97029	-118.42379	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57978	16041-20002-19401	3239 N PASADENA AVE Unit B	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/30/2016 12:00:00 AM			Not Ready to Issue	06/30/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	Revisions to approved set.  Change of inverter type from central inverter to microinverters.  Reduction of (10) modules from system to a total of (10) modules for this system.(((PV2.  Install 5.7 kW DC roof mounted PV system.  (20) modules with (1) 5 kW transformerless inverter with power optimizers.  2 of 3 PV systems proposed for property submitted concurrently.Zoning clearance obtained under 16041-20000-19398))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57979	17041-10008-00340	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM			PC Approved	12/14/2019 12:00:00 AM	ADDRESS	34.16326	-118.37388	"DELTA ""A"" & ""B"" changes to aproved plans for removing all lights from all bedrooms and living rooms and providing ""Half Switched Receptacles"" AND replacing all lights in dining rooms with ""Track Lights"".(Original Plan Checker was Edwin)<<<<Full PC for power and energy. New mixed use housing complex -297 dwelling-unit 6 levels of apartment on top of on grade market (core and shell)  above 2 -level of type I construction parking garage.  Scope includes three new services/distribution boards(2500A & 1600A), new panels, new circuits, and new lights for two structures. Total affected area is 266331 Sq. Ft.  B#16010-10000-04268((((BUILDING COVERS TWO ADDRESSES:  5101 LANKERSHIM BLVD AND 5130 KLUMP AVE.))))))>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57980	19041-10000-25515	6956 W 85TH ST	90045	11	096B161   460	4112002033	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Expired	03/20/2024 12:00:00 AM	ADDRESS	33.96109	-118.41265	[e-plan] PV1. PLAN CHECK PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE5000H-US) WITH 15 MODULES  USING P400 NOPTIMIZERS AND 1 ESS SYSTEM(TESLA POWER WALL) CONNECTED TO EXISTING 125A SERVICE PANEL WITH EXISTING 100A SERVICE. SYSTEM SIZE IS 5KWac AND 4.95KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
57981	19041-10000-13044	19218 W MALDEN ST	91324	12	192B117   214	2784006053	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.22544	-118.55199	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.78KWdc / 9.120KWac.(38)MODULES-(38)MICROINVERTERS-IQ7-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57982	17041-20000-42713	3500 W WILSHIRE BLVD # 207	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.06157	-118.30077	TENANT IMPROVEMENT TO (E) FOOD COURT.  808 SQFT.  PLANCHECK FOR T24 ENERGY. BUILDING PERMIT # 17016-10000-19814	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57983	19041-10000-26118	1327 N SEWARD ST	90028	4	147A185   327	5547029015	RD1.5-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.09514	-118.33332	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 MODULES (SP-E19-320), 20 OPTIMIZERS (SE P400) AND 1 CENTRAL INVERTER (SE5000H-US). SYSTEM SIZE IS 5.76KWdc AND 5KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57984	19041-10000-29714	22611 W VENTURA BLVD	91364	3	171B097   168	2040028002	C1.5-1VLD, QP-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.16752	-118.61925	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57985	11041-10000-00860	15821 W VENTURA BLVD	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	05/10/2011 12:00:00 AM	ADDRESS	34.15584	-118.47812	Ti in an existing office. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57986	12041-10000-08952	301 S WESTERN AVE 110-111	90020	10	135B193   233	5503002022	C2-1	Central	Wilshire			2117.03	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			PC Approved	04/19/2012 12:00:00 AM	ADDRESS	34.06877	-118.30952	T.I. to an existing Beauty Salon.  Less than 200A of Load and occupancy load is 14, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57987	16041-10000-34538	5077 N LANKERSHIM BLVD Suite B	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.1626	-118.37361	Plan check for power and Title-24.  First time tenant.  New restaraunt in 5 story mixed use building. One new 200 A panel with associated lighting, HVAC, and plug loads.  Total area = 945 sq. ft.         Original building permit is 08010-20000-01500.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57988	14041-20000-02626	11120 W HUSTON ST 1-34	91601	2	168B173   208	2353020031	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.15954	-118.37245	New 4-story, low rise residential building with 34 unit apartment.  New 1200A service.  Plan check for power and energy.  Note: Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57989	11041-10000-03554	10006 S BROADWAY	90003	8	091-5A203 121	6053022008	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Public Safety Only			02/24/2011 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	33.9453	-118.27796	NEW FIRE ALARM SYSTEM FOR 4-STORIES APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57990	14041-20000-28053	4354 N TEESDALE AVE	91604	2	165B161   332	2375003044	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			10/09/2014 12:00:00 AM			PC Info Complete	10/09/2014 12:00:00 AM	ADDRESS	34.14998	-118.40825	NEW FIRE ALARM SYSTEM IN AN EXISTING 16 UNIT APARTMENT BUILDING.  4 STORIES OVER ONE LEVEL GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57991	16041-20000-13389	350 S GRAND AVE STE 3910	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	04/18/2016 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for Title 24 only. Project site is a portion of the 39th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,279 sq. ft.Note: Building application has been created under 16016-10000-07675	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57992	17041-10003-28602	11433 W ALBERS ST	91601	2	174B169  1079	2350007049	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			02/04/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.17056	-118.38016	Changes to an permitted set of plan. All changes are clouded under delta D.  Changes include revising single line diagram, adding 5 additional circuit, and revising load calculation, and revising title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
57993	14041-20000-15339	18942 W PLUMMER ST	91324	12	198B121    77	2762028002	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.24261	-118.54635	PV1Central Transformerless Inverter Standard Plan.Install roof-mounted solar array on SFD. System size: 4.2kW(1) Power-One PVI-4.2-OUTD-S-US-A transformerless inverter(20) Renesola Jinagsu: JC255M-24/BXH pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
57994	15041-10000-03236	801 S HOPE ST UNIT A	90017	14	129A209   268		C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.04656	-118.25938	First time tenant restaurant in (E) highrise building.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57995	11041-20000-18519	14800 W VENTURA BLVD 8TH FL.	91403	5	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	07/02/2012 12:00:00 AM	ADDRESS	34.15186	-118.45547	8th floor t.i. / PHASE 2complete plan checkRequest for Modification to separate Fire Alarm system filed .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57996	16041-10001-03395	2226 N STRADELLA ROAD	90077	5	153B145   176	4377029005	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM			PC Approved	02/29/2016 12:00:00 AM	ADDRESS	34.11332	-118.46236	Expedite per applicant requestPV1 28kW AC roof mounted system with (91) SunPower SPR-x21 modules, and (2) CPS SC 14KTL inverter interconncecting through the main existing 1000-Amp service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57997	12041-30001-30870	4801-4803 W ADAMS BLVD	90016	10	123B181   955	5057002005	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM			PC Info Complete	12/01/2017 12:00:00 AM	ADDRESS	34.03269	-118.34516	PLAN CHECK FOR LOST SET OF PLAN. MIXED USE: NEW 6 UNIT APARTMENT BUILDING, LOW INCOME HOUSING W/ GROUND LEVEL RETAIL AND ACCESSORY OFFICE USE.  3 STORY BUILDINGNOTE: ADDRESS IS 4801-4803 W ADAMS BLVD PER BUILDING APPLICATION NUMBER: 12010-10000-02534	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57998	16041-10001-06178	3060 W OLYMPIC BLVD	90006	10	129B193   469	5080030019	C2-1, R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			08/25/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.05239	-118.30229	CHANGES TO APPROVED SET OF PLANS -  NOTE CHANGES ON DELTA 3,6,7 AND 8. CHANGES INCLUDE LOAD CALCULATIONS, FEEDER SCHEDULE(EGC & UNGROUNDED CONDUCTORS),  ADDITION OF NEW LOAD AND CORRECTING LIGHTING LAYOUT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
57999	13041-10000-35268	7950 W SUNSET BLVD STE # 105	90046	4	147B177  1021	5554003055	(Q)RAS4-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	12/18/2013 12:00:00 AM	ADDRESS	34.09777	-118.36322	"T24 PART 6 ENERGY FOR (E) RESTAURANT (""9021 PHO ) . TENANT IMPROVEMENT; SCOPE OF WORK < 400A. PROJECTED AREA IN SCOPE OF LIGHTING WORK IS APPROX. 1886 SQ FT.  ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58000	19041-20000-16352	20740 W BEECH CIR #308-pv1	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.29352	-118.58554	pv1install roof mounted pv system sized 3.02KW AC interconnected with msp.(9) acm with 335W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58001	14041-10000-06367	1114 E 8TH ST #101	90021	14	124-5A213 367	5146019007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.03501	-118.24516	T24, REMOVING HID LIGHT FIXTURES WITH NEW FLORESCENT FIXTURS. TOTAL AREA 2227 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58002	17041-10000-30161	1716 N SAN REMO DR	90272	11	135B133   200	4432007022	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			No Progress	08/06/2018 12:00:00 AM	ADDRESS	34.06305	-118.49971	SFD W/ATTACHED GARAGE 3 STORY W/BASEMENT. PC FOR POWER SYSTEM ONLY. PC ONLY. PERMIT ISSUED UNDER BUILDING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58003	10041-10001-01359	1884 E 22ND ST	90058	14	117A215     6	5167006021	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM			PC Approved	02/08/2010 12:00:00 AM	ADDRESS	34.0169	-118.23653	Suppl. EPC for Title 24 Energy Calcs for relocation switches per inspector's request. Tenant improvement for existing industrial building.  Install new general lighting in cooler areas.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58004	18041-10000-09952	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.12626	-118.21412	FULL PLAN CHECK FOR THE ANDERSON CENTER AND BIOSCIENCE BUILDING.  SCOPE INCLUDES RENOVATIONS AND ADDITION OF 860 SF OF STORAGE WITH NEW LIGHTING AND EQUIPMENT COVERING A TOTAL TITLE-24 AREA OF 8,000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58005	12041-10000-01099	544 N LILLIAN WAY	90004	4	141B185  1006	5523009026	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Approved	01/30/2012 12:00:00 AM	ADDRESS	34.08023	-118.32823	New  9.9KW  44 MODULES/4 STRINGS  Photovoltaic system  to be installed on the roof of a SFD. EPC is for power. Permit obtained on 11041-10000-26112	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58006	17041-10000-06631	215 W 7TH ST #203	90014	14	127-5A211 340	5144026***	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.04496	-118.25266	PC for T24 only for tea shop. Load is under 400 A. Total affected area is 511 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58007	15041-10000-23185	726 N LA BREA AVE	90038	5	141B181   449	5525008040	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.08425	-118.34386	TI 24 REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ FT = 2914 NUMBER OF BRANCH UNITS = 9	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58008	17041-20001-40242	4416 N LIBBIT AVE	91436	5	165B137    30	2284010009	RE15-1-H	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM			PC Approved	11/16/2017 12:00:00 AM	ADDRESS	34.1526	-118.49492	EXPEDITEPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58009	19041-20000-38028	611 S LA BREA AVE	90036	4	135B181   628	5508007015	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	34.06454	-118.34421	Plugs, lights, and lighting controls for existing commercial building.  Plan check for Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58010	15041-10001-07391	8431 W MELROSE PL	90069	5	141B173   416	5528001030	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	34.08376	-118.37442	Changes to approved set.  Additional proposed lighting added and additional panel to supply additional lighting loads.  (((TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1387)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58011	17041-10000-24566	2300 E CENTURY BLVD 101-302	90002	15	091-5A217 109	6046019921	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/07/2021 12:00:00 AM	ADDRESS	33.94631	-118.2307	POWER PALN CHECK FOR A  3-STORY, 17-UNIT APARTMENT BUILDING. SCOPE INCLUDING A 800A SERVICE AND (18) PANELS.NOTE TO PLAN CHECKER, VERY THE FLR PLAN AND PANEL FOR FEE CALCULATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58012	10041-10000-06881	201 N PARK PASEO	90033	14, 3	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		1343.06	Electrical	Electrical	Apartment			04/15/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	34.04901	-118.22591	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58013	18041-20000-07872	4419 N FIGUEROA ST	90065	1	147A223   287	5467005027	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1851.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.09571	-118.20777	"addition of 200 amp panel to an existig distribution board ""MSB"" for a carwash.  plan check for power only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58014	19041-10001-25540	18220 W SHERMAN WAY	91335	3	183B125   217	2125036021	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.20092	-118.5303	Changes to an approved set of plans, changes include the addition of smoke detectors and relays. Note changes to clouded areas. __________________________________________Plan check for a fire alarm system located in a a 2-story commercial building. Scope includes (1) fire alarm panel, (1) communication panel, and (65) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58015	17041-20000-01215	10738 W RIVERSIDE DR #A	91602	4	165B177    94	2423005015	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.15208	-118.36495	"Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,160 sq. ft.   ""COMPLY WITH DEPARTMENT ORDER effective date12/28/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58016	15041-10000-32220	3973 S NORMANDIE AVE	90062	8	114B193   138	5036016017	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	PIN	34.01221053	-118.30050995	PV1. NEW ROOF MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 3KW. (12) MODULES- KYOCERA #KU2656ZPA(1) INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58017	12041-20000-06716	7726 N GLORIA AVE	91406	6	189B141   256	2206010026	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Issued	03/23/2012 12:00:00 AM	ADDRESS	34.21103	-118.47917	Pet Clinic t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58018	14041-10000-10318	812 N CORONADO ST	90026	13	139-5A205 181	5402021011	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1957.10	Electrical	Electrical	Apartment			04/18/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.07696	-118.27038	PV2 ROOFTOP TRANSFORMERLESS SYSTEM USING SOLAR EDGE OPTIMIZERS FOR DUPLEX? TOTAL SYSTEM SIZE IS 3.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58019	17041-20000-35954	17947 W VALLEY VISTA BLVD	91316	5	168B129   353	2182013016	R1-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.15817	-118.52358	pv1install roof mounted pv system sized 10.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58020	19041-10000-22952	7907 S MCCONNELL AVE	90045	11	099B161   404	4112008020	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	33.96768	-118.4133	[E-PLAN] Install 2 Energy Storage Systems @ 27KWH to an existing PV system. scope includes new 200A Load Center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58021	16041-10000-23859	10700 W SANTA MONICA BLVD UNIT 140	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	04/26/2017 12:00:00 AM		Issued	04/26/2017 12:00:00 AM	ADDRESS	34.05167	-118.432	PC FOR MEDICAL TI. NEW DENTAL CLINIC. PC FOR POWER AND ENERGY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58022	13041-10000-21082	2202 S MALCOLM AVE	90064	5	126B157   140	4320006048	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.04479	-118.42964	PV1 4.165KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: powerone PVI-5000-OUTD-US-Z] [( 17) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58023	12041-10000-23290	9700 N FARRALONE AVE	91311	12	201B101   386	2727011006	RA-1, RE11-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.2462	-118.61025	New 9.2 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58024	19041-10000-43423	2208 S UNION AVE	90007	1	124-5A201 209	5124006023	C2-1VL-O-HPOZ-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.03535	-118.28303	REMOVED HID FIXTURES AND REAPLCE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58025	19041-20000-52277	9779 W PICO BLVD	90035	5	132A165   316	4330013001	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Info Complete	12/18/2019 12:00:00 AM	ADDRESS	34.0542	-118.40199	TENANT IMPROVEMENT PLAN CHECK FOR TITLE-24 ONLY. SCOPE OF WORK IS ONLY RETAIL AREA OF GAS STATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58026	15041-10001-38928	5330 N LOLETA AVE	90041	14	163-5A227  24	5691001012	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	34.14427	-118.198	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, ROOF MOUNTED SYSTEM. INSTALLING (25) MODULES AND (2) 4.2 INVERTERS. TOTAL SIZE 8.4KW-AC.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58027	19041-20000-16074	8986 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.23341	-118.55337	Plan check for Title 24 only. Project site is an existing commercial tenant space in a commercial building. Project scope is a change of use from retail to veterinary clinic. Total lighting area = 4,320 sq. ft.Note: Building application has been generated under 19016-20000-12755	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58028	12041-20000-00661	1912 S TOBERMAN ST	90007	1	124-5A203  29	5124016010	R3-1-HPOZ, [Q]C2-2-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			01/11/2012 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	ADDRESS	34.03715	-118.27966	Plan check T24 Energy/Emergency lighting for TI of existing charter school. New offices, storage, and corridor spaces. Permit for new branch circuits and AC unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58029	17041-10000-30683	523 W 6TH ST SUITE 1134	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	Pc for T24 only for new lights on 11th floor Office TI. Total area of 3136 sqft. Installing new ciruits. Building# 17016-10000-18928.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58030	17041-10000-00281	20105 W SATICOY ST	91306	3	186B113   177	2114004047	C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.20848	-118.57133	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA (OUTDOOR) 11650 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58031	14041-10001-04950	4050 N HARCLARE LANE	91436	5	165B137   584	2291016021	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	ADDRESS	34.14445	-118.49136	PV1, INSTALL 6.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE6000A-US-ZB-U(27) MODULES: TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58032	13041-10000-08582	333 S HOPE ST 15TH FL	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	REMODELING EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCDY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58033	18041-10000-17066	2320 W BERKELEY AVE	90026	13	142-5A207 248	5424003004	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Issued	05/09/2018 12:00:00 AM	ADDRESS	34.08464	-118.26289	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 27 AC MODULES WITH NEW LOAD CENTER. TOTAL SYSTEM SIZE 9.72KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58034	19041-20000-42791	6056 W JEFFERSON BLVD	90016	10	117B169     7	4204008011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		7025.02	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.02058	-118.3807	Plan check for methane system, addition of 10 methane sensors to existing system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58035	12041-10000-17050	338 S WESTERN AVE F	90020	10	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM			PC Approved	07/23/2012 12:00:00 AM	ADDRESS	34.06777	-118.30889	Modification to previously approved set of drawings 12041-10000-17050 to change switching from dual switches to dimmers and change emergency lighting fixture type only.  PLAN CHECK ONLY for T-24 Only, with Emergency lighting.                <<<<<CONVERT PORTION OF EXISTING COMMERCIAL BUILDING FROM RETAIL TO MEDICAL OFFICE>>>>>.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58036	17041-10001-07839	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	Yes	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	ADDRESS	34.24912	-118.34256	Expedite per applicant request. Plan check for PV roof mounted system. System size:  6kW with 21 modules and 1 inverter(6.0kW) with Tesla battary back up	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58037	12041-20000-12049	12210 1/2 W NEBRASKA AVE	90025	11	123B149   265	4259018012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/24/2012 12:00:00 AM	ADDRESS	34.03549	-118.45855	energy plan check car show room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58038	11041-10001-17025	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	PLANS REVISED TO INCLUDE CHANGES TO PERMITTED SET OF PLANS- A 9KW HEATER 480V 3PH; ADED 2 EA NEW CIRCUITS AND REVISED A FEW circuits FROM 1POLE 1PH TO 2-POLES 1PH; PROVIDE SUMMARY SCHEDULE FORPHOTOMETRIC RESULTS; NO CHANGES TO THE LIGHTING SYSTEMT.I.  Core and shell.  New gym to occupy the space.  Two story building. Plan check is for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58039	17041-10000-41132	5715 N FIGUEROA ST # 101	90042	1	151-5A229 170	5492001015	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.10994	-118.19246	ALTERATIONS IN EXISTING RESTAURANTPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58040	11041-10000-17789	609 S GRAND AVE	90017		129A209    68	5144005022							Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/25/2011 12:00:00 AM	ADDRESS	34.04858	-118.25572	TI TO AN EXISTING RESTAURANT.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58041	14041-20000-12184	5816 N CLEON AVE	91601	2	174B173   237	2415011005	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.1764	-118.36798	PV1 SINGLE FAMILY. USING STANDARD PLAN. USING MICROINVERTER ENPHASE M215. 2.8KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58042	13041-10000-13195	347 W 6TH ST	90731	15	015B201   126	7455012009	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	33.73863	-118.28448	New restaurant in an existing space.  Existing service and panel, new lighting and receptacles.  Title 24 plan check only.  CRA clearance to be obtained on this application for the future express permit.  (Permit fees are under INSPECTION)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58043	16041-20000-31279	10231 W MCBROOM ST	91040	7	207B181   309	2543007022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.26483	-118.35253	"""0$ permit fees due to senate bill 1222 ""BATTERY STORAGE SYSTEM  + PV1 ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.16 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58044	18041-20000-41260	2455 N RIVERSIDE PL	90039	13	148-5A211 125	5440026027	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Issued	10/29/2018 12:00:00 AM	ADDRESS	34.10154	-118.25327	Plan check for a PV1 roof-mounted PV system. System size is 7.92 kWdc/7.04 kWac and consists of (22) AC PV modules and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58045	10041-30000-00719	5115 W ADAMS BLVD	90016	10	123B181   939	5049009046	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2185.00	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.03267	-118.35238	TI - commercial - showroom / offices - Permit is for new fixtures on existing ckts.  P/C is for Energy and emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58046	15041-10000-11690	2945 S 6TH AVE	90018	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.02815	-118.32371	PV1.  3.6KW roof-mounted system with (1) 3.6-ABB INVERTER and (16) Kyocera KU260 modules connecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58047	19041-10001-23997	232 E 2ND ST E	90012	14	129A213    28	5161024034		Central				2062.00	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.0495	-118.24258	DELTA 15 CHANGES ONLY TO THE LIGHTING PLAN AND T-24 CALCULATION. Original Scope: T-24 PLAN CHECK FOR TI (Change of use from Retail to Restaurant). SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTL AFFECTED AREA IS 3381 SQ.FTNew Connected load less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58048	19041-10001-48863	3914 S SOMERSET DR	90008	10	117B185  1002	5045015025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.01474	-118.33809	PLAN CHECK ONLY. SCOPE OF WORK INCLUDES REVISION OF MODULE TYPE, NOTE ALL CHANGES UNDER CLOUDED AREAS.  __________________________________________________________Plan check for photovoltiac system, system size is 3.135KW. 11 modules with P320 solaredge optimizers. (1) SE3800H inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58049	12041-20000-12962	4619 N WILLENS AVE	91364	3	168B097   674	2074042037	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2012 12:00:00 AM			PC Approved	08/06/2012 12:00:00 AM	ADDRESS	34.1541	-118.62578	New roof mounted P.V. system (5.6KWdc)  with micro-inverter.For permits see 12041-20000-09130 and supplement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58050	11041-10001-03852	1947-2001 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			09/12/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.10686	-118.33085	REVISED PERMITTED SET OF PLANS:REFEED 25HP ELEV FROM PANEL HPA WHICH IS SUPPLIED FROM THE SAME BUS AS THE ELEV; ELEMINATE METER SECTION RTS-3 AND 400A DISCONNECT SWITCHAND REFEED LOADS FROM RTS-1 AND RTS-2; HEATER LOADS CHANGE TO 1PH 2-POLES;RECALCULATED ALL LOADS. CHANGES ARE CLOUDED ON NEW SET OF PLANS AND REFEREED TO AS DELTA 1 CHANGES((((((((((THESE PLANS ARE AS-BUILT SET OF PLANS APPROVED UNDER APPLICATION 07041-20000-20547 .PERMIT WERE OBTAINED SEPARATELY UNDER APPLICATIONS 07041-20000-07966. FIRE ALARM PLANS WERE APPROVED UNDER 10041-10000-00239. THESE PLANS WILL BE REVIEWED ON HOURLY BASIS .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58051	17041-10000-42940	380-384 WORLD WAY MSC-Fuel	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR POWER ONLY FOR A FUEL SHUT-OFF SYSTEM AT LAX. SCOPE INCLUDES ADDING A NEW PLC BASED EMERGENCY FUEL SHUT-OFF SYSTEM FOR A NEW HYDRANT FUEL LOOP AT MSC TERMINAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58052	15041-10000-39284	2727 S BEVERLY DR	90034	5	126B165  1085	4309023027	R1-1	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.03748	-118.39635	PV1, ROOF MOUNTED SOLAR SYSTEM WITH (45) MODLUES AND (1) INVERTER. TOTAL SIZE 11.4 KW-AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58053	17041-10000-01975	5228 W CENTINELA AVE	90045	11	102B173    97	4103002015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	33.97713	-118.37147	T24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, TOTAL AREA 13625 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58054	14041-10000-26169	1331 W 7TH ST	90017	1	130-5A205  84	5143013012	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			09/23/2014 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	34.05283	-118.26842	fire alarm variance to be filed before issuance of permit..plan check for power and energy. 2008 energy standards. NEW SEVEN(7) STORY 87 unit MIXED USE APARTMENT/RETAIL WITH 5 STORY TYPE IIIA OVER 2 STORY TYPE I BLDG.  BLDG#14010-10-01721	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58055	13041-20000-15657	12401 W VENTURA BLVD 1-2	91604	2	162B165   190	2367018036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.14303	-118.40318	New bakery in an existing commercial space.  Load is less than 400 amps and not a first time tenant per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58056	19041-10000-36120	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916		Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	07/01/2020 12:00:00 AM		Permit Finaled	05/11/2021 12:00:00 AM	ADDRESS	33.78054	-118.23195	PHASE 2 POWER PLAN CHECK FOR ALL EQUIPMENT AND WIRING FROM THE SECONDARY OF THE 1500KVA TRANSFORMERS TO (2) 3000A 480V SWITCHGEARS FOR THE COKE DRUM SIS PROJECT.ENGINEER TO IGNORE CLOUDS. GENERAL LIGHTING AND POWER FOR THE BUILDING WILL BE SUBMITTED SEPERATELY. Original Discription: PHASE 1 POWER PLAN CHECK FOR THE ADDITION OF 2 1500KVA TRANSFORMERS CONNECTED TO 3000A MEDIUM VOLTAGE EXISTING SWITCHGEAR. THE SCOPE IS FOR THE 5KV  ELECTRICAL CABLE CONNECTION FROM EXISTING SWITCHGEAR (MEDIUM VOLTAGE) TO THE PRIMARY OF THE TRANSFORMER. ALL OTHER EQUIPMENT FROM THE SECONDARY OF THE TRANSFORMER ARE SHOWN FOR REFERANCE ONLY AND WILL BE SUBMITTED UNDER PHASE 2. Customer discription: INSTALLATION OF 5KV ELECTRICAL CABLE IN EXISTING UNDERGROUND DUCT BANKS. 5KV CABLE CONNECTIONS TO NEW BREAKERS IN EXISTING SWITCHGEAR (SUB 7) AND CONNECTION TO NEW OIL FILLED TRANSFORMERS FOR NEW SUN 10.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58057	10041-10000-10030	333 S ALAMEDA ST	90013	9	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	10/07/2011 12:00:00 AM	ADDRESS	34.04448	-118.23824	Change of use from game shop to the restaurant. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58058	14041-20001-21783	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.21328	-118.45279	08-02-16 Changes to an approved set of plans. Changes include remove PV carport from scope of work, as build layout of modules, change inverters from (6) 100kW to (18) 20kW and down size PV  system to 360kW. *****************Previouse Work Description***********************************$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.PV2 COMMERCIAL ROOFTOP. PLAN CHECK FOR FOR ROOF MOUNTED PV IN 2 LOCATIONS. ONE ON EXISTING BUILDING AND ANOTHER ON NEW PARKING CANOPY. ALL FALLS UNDER SAME PV SYSTEM. TOTAL SYSTEM SIZE 600KW AC USING 6 CENTRAL INVERTERS. TOTAL 664KW DC. CONNECTION TO 480V 1000A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58059	14041-10000-29466	415 E ADAMS BLVD	90011	9	120A207   161	5127011033	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Apartment			10/23/2014 12:00:00 AM	03/04/2016 12:00:00 AM		Issued	03/04/2016 12:00:00 AM	ADDRESS	34.02335	-118.26491	$0 permit fee is due to State Senate Bill SB-1222. Installation of new 31.2 kW AC roof mounted solar array.  132 modules on 12 strings (11 modules each) with 6 inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58060	14041-10001-17295	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM			Corrections Issued	07/03/2014 12:00:00 AM	ADDRESS	34.05436	-118.25543	Changes made to approved set.  Increase in area and power for some lighting.PLANCHECK FOR T24 ENERGY, TENANT IMPROVEMENT FOR 3RD FLOOR . HIGHRISE. FLOOR CONSISTS OF COMMERICIAL AND HOTEL ROOMS. 2596 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58061	18041-10000-00485	120 W G ST	90744	15	030B205   643	7423001004	[Q]C2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	33.77832	-118.26321	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58062	17041-20000-05258	9175 N DEERING AVE	91311	12	198B105   137	2746010028	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.23756	-118.59629	Plan check for power only. Project site is an existing commercial building. Project scope is a 1,600-amp service upgrade only. All subpanels are existing to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58063	13041-20003-30907	1416 N LA BREA AVE	90028	4	147B181   794	5548017021	[Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	ADDRESS	34.09656	-118.34388	New 199KW rooftop PV system for an existing commercial building.(((( $0 permit fee is due to the 2012 Senate Bill No. 1222))))) (((chnages to approved set of plans. modifactions. no change in design or loads. changes clouded delta 3)))) variance has been filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58064	12041-20000-11578	14117 W HUBBARD ST unit 10	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.29849	-118.44081	Ti first time tenant. Plan check for power, energy, and emergency lighting. 1239 conditioned floor area.   medical use of space in single story commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58065	15041-10000-07993	660 S FIGUEROA ST # 2050	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	34.04953	-118.25947	ALTERATIONS IN OFFICE AREAS-NEW PANELS AND NEW CIRCUITSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58066	19041-20000-38070	1205 S CORNING ST	90035	5	132B173   955	4332027030	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.0554	-118.3775	New fire alarm system for existing apartment building.  (84) signaling and notification devices, FACP, and GSM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58067	16041-20000-19958	5723 S ST ANDREWS PL	90062	8	108B193  1136	5005023020	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/23/2016 12:00:00 AM	ADDRESS	33.99029	-118.31148	PV1.  Install 3.75 kW roof-mounted PV system.  (13) modules with (1) 3.8 kW rated central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58068	13041-20000-06510	1324 N BENEDICT CANYON DR PV-1	90210	5	147B157   434	4356011006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.09535	-118.42973	Install a new Ground Mounted PV System for an existing single-family residence.  System uses Micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58069	14041-20000-20807	2428-2436 E HUNTER ST	90021	14	121-5A217 196	5168030007	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.02744	-118.22882	Upgrading main service from (2) 200 Amp  single and 3phase services to a 800 Amp 3Phase 4-wire service. Contractor also removed all service board, and add (3) new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58070	16041-10001-45512	6000 N SEPULVEDA BLVD # 1450	91411	6	177B145   439	2242026009	M3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM			PC Approved	03/24/2017 12:00:00 AM	ADDRESS	34.17961	-118.46592	Changes to approved set of plans. Relocating/removing fan coils and revising floor plans. Changes under Delta R2. No changes to panels schedules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58071	11041-10000-14377	13515 W ROMANY DR	90272	11	132B133   284	4425030010	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2011 12:00:00 AM	07/12/2011 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	34.05514	-118.5001	New roof mounted 5.598 KW solar system.  Applicant is using the standard drawing for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58072	14041-10001-23948	3323 S CLUB DR	90064	5	123B165   761	4316025013	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	ADDRESS	34.03234	-118.40276	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{INSTALL 10.965 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(43) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGED SE5000A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58073	17041-10002-25672	4151 W PROSPECT AVE BLDG A	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Issued	04/25/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	PER INSPECTOR REQUEST, CHANGING PROJECT DESCRIPTION FROM (RELOCATING) TO (NEW WORK) OF 1200A SWITCHBOARD AND INSTALLING NEW 750KVA .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58074	12041-10000-05803	5757 W CENTURY BLVD	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	07/12/2012 12:00:00 AM	ADDRESS	33.9457	-118.38274	existing fire alarm for 8 story plus pent house. one panel , battery cabinet, and 2 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58075	18041-20000-25672	15533 W SANDRA LANE	91342	7	222B145    98	2604011046	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.3073	-118.47172	Plan check for PV roof mounted system, system size: 7.6KW AC with 11 modules and 1 inverter(7.6KW) connected to Center fed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58076	19041-20000-39644	14114 W POLK ST	91342	7	225B153   221	2504019048	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			Reviewed by Supervisor	11/04/2019 12:00:00 AM	ADDRESS	34.31502	-118.44105	PV3 PLAN CHECK FOR NEW SOLAR CARPORT FOR A COMMERCIAL LOW RISE. SYSTEM SIZE IS 21.09 KW DC/19.208 KW AC CEC. SCOPE OF WORK CONSISTS OF (57) PV MODULES WITH OPTIMIZERS AND (2) 10KW INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58077	10041-20000-12421	12424 W WILSHIRE BLVD	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Public Safety Only			06/29/2010 12:00:00 AM			PC Info Complete	09/01/2010 12:00:00 AM	ADDRESS	34.04135	-118.47058	Plan check for fire alarm system replacement and upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58078	11041-10000-03784	3700 S CRENSHAW BLVD	90018	10	117B185   192	5033001024	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM			PC Info Complete	08/01/2011 12:00:00 AM	ADDRESS	34.01949	-118.33473	New commercial retail buildingwith parking.  Electrical and energy plan check.  Inspecotor to verify elevator motor duty cycle are 30/60 minute.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58079	18041-10000-13059	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	TI INA NEW RESTAURANT / LOUNGE - POLARIS - IN TERMINAL 7 OF LAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58080	16041-10001-45736	355 S GRAND AVE STE 3150	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			Corrections Issued	06/20/2017 12:00:00 AM	ADDRESS	34.05191	-118.2525	CHANGES TO APPROVED SET OF PLANS. CHANES NOTED DELTA 1 ON PLANS. CHANGE TO LIGHTING TYPE, CONTROLS, AND UPDTED T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58081	17041-20000-41026	12870 N PHILLIPPI AVE	91342	7	222B153   363	2509017003	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	PIN	34.30454909	-118.43527689	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58082	11041-20000-04487	12412 W PACIFIC AVE	90066	11	111B153   384	4235014002	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.00	Electrical	Electrical	Apartment			03/08/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.00241	-118.43318	New 12 units apartment.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58083	16041-10000-44659	2466 E 16TH ST 1ST FLR-MEZZANINE	90021	14	118-5A217 294	5168010013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM			Corrections Issued	12/20/2016 12:00:00 AM	ADDRESS	34.01949	-118.2277	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 2940 SQ. FT. B#16016-10000-30124	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58084	19041-20000-40366	14521 W SHERMAN WAY unit A	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Issued	10/04/2019 12:00:00 AM	ADDRESS	34.20136	-118.44968	Tenant improvement for beauty salon new lighting and receptacle, Title 24 energy. Total area: 1466 sq ftB#19016-20000-28083	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58085	16041-10000-22904	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	NEW HVAC EQUIPMENT. NEW POWER TRANSFORMER AND DISTRIBUTION. PC FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58086	14041-10002-21157	20311 W HOWARD CT	91364	3	165B113   167	2174008022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	34.14734	-118.57619	((((5/27/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES MARKED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REDRAWING OF SERVICE EQUIPMENT.  PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 12kW(1) SolarEdge SE11400A-US transformerless inverter(40) SunPower X21-345 pv modules(40) SolarEdge P400 power optimizers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58087	14041-10000-13457	3280 N BENNETT DR	90068	4	157-5A181 222	2429013011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.1261	-118.34884	install rooftop solar pannels.Total system size = 8 kW. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58088	15041-10001-33079	2510 S FIGUEROA ST STE-H	90007	9	121-5A203  24	5124027017	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.02877	-118.27529	04/18/2016CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE RELOCATION OF CIRCUITS. NOTE CHANGES ON DELTA 3.  PC ONLY TO REFLECT THE FLOOR PLAN.(((Energy plan check for a retail (T-mobile) T.I. Scope includes new lighting and receptacles; Total area is 1568-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58089	11041-10000-22365	138 E CULVER BLVD	90293	11	096B149   530	4116007069	[Q]C4-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	10/19/2011 12:00:00 AM		Permit Expired	11/12/2013 12:00:00 AM	ADDRESS	33.95782	-118.44919	TEMPORARY POWER FOR CONSTRUCTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58090	15041-20000-30794	20142 W WELLS DR	91364	3	171B113   516	2175024002	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.16115	-118.57129	PV1. NEW ROOF-MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 4.2 KW. UNGROUNDED SYSTEM.(21) MODULES- KYOCERA # KU2656ZPA(1) INVERTER- ABB#PVI-4.2-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58091	19041-10000-38861	11408 S CENTRAL AVE	90059	15	087A211   166	6070016006	C2-1VL	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	Apartment			09/26/2019 12:00:00 AM	06/25/2020 12:00:00 AM		Permit Finaled	05/20/2022 12:00:00 AM	ADDRESS	33.93064	-118.25406	PLAN CHECK FOR A NEW 1600A SERVICE (120/208 3P,4W), THAT FEEDS A 800A HOUSE DISTRIBUTION BOARD WHICH FEEDS SEVERAL HOUSE PANELS AND TWO ELEVATORS. THE 1600A SERVICE ALSO FEEDS A 1000A METERING SWITCHBOARD. TOTLA AFFECTED AREEA IS 25,520 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58092	16041-10000-07547	1801 E 41ST ST	90058	9	115-5A215  65	5117021020	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/19/2023 12:00:00 AM	ADDRESS	34.0082	-118.24102	FULL PC FOR POWER AND ENERGY FOR A NEW CONCRETE TILT-UP INDUSTRIAL BUILDING (CORE & SHELL). SCOPE INCLUDES A NEW 2000A 277/480V 3 PHASE, 4 WIIRE SERVICE.  TOTAL AFFECTED AREA IS 125,125 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58093	14041-20000-08932	8134 W FOOTHILL BLVD	91040	7	204B193   156	2559001010	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.2595	-118.31045	new control panel and addition of 4 devices. new system. pc for fire alarm only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58094	16041-10001-11886	1425 S COURTLAND AVE	90006	1	127-5A201 133	5135008028	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2243.10	Electrical	Electrical	Apartment			06/14/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.0444	-118.28366	PV2. PC FOR A SOLAR SYSTEM ON EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE IS 3.0KWac. (9)MODULES-KYOCERA #K255GX-LFB3(1)INVERTER-PVI-3.0-OUTD-S-US-Z-ANOTE: PERMIT PULLED UNDER PCIS#16041-90000-11886((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58095	14041-10000-17537	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	08/11/2014 12:00:00 AM	PIN	34.0586034	-118.41904766	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT .LOADING DOCK. Changes on plan : 300kw generator.  NEWLY CONNECTED LOAD < 400 AMPS. 30.276 SQFT. BLDG#14016-10-07923.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58096	19041-20000-28480	6080 W CENTER DR 11th flr	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58097	16041-10002-43693	1035 N SWARTHMORE AVE Bldg 1	90272	11	129B125   837	4423016022	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	DELTA 60 REVISION- ADDED EXIT SIGNS IN THE SERVICE CORRIDORPLAN CHECK ONLY((((((((Full Plan check for new retail and theatre building, core and shell, 1 story. New service rated at 5000 Amps 480/277V 3phase 4wire. Indoor and outodoor title 24. Total area: 7250.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58098	19041-10000-01106	300 S FALCON ST	90744	15	024B205    40	7440019001	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	33.75794	-118.26677	PC T-24 ONLT, SCOPE : 110 SQFT NEW CONTROLS OFFICE TO BE BUILT INSIDE STORAGE ROOM OF STEAM PLANT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58099	12041-10000-30454	3258 W SAGAMORE WAY	90065	14	159A215   159	5678029003	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2012 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.12915	-118.23492	PV1:  NEW 6.82 KW ROOF MOUNTED PV SYSTEM FOR A SINGLE FAMILY RESIDENCE.  INSTALLING 1 TRANSFORMERLESS INVERTER, 1 COMBINER BOX,  AND 31 MODULES.NOTE: BOE IS UPDATING THE ADDRESS FROM 4311 N CALEDONIA WAY TO 3258 W SAGAMORE WAY.  DO NOT ISSUE PERMIT UNTIL THE ADDRESS UPDATE IS COMPLETE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58100	16041-20001-25521	10910 W PEACH GROVE ST	91601	2	168B173   314	2421014031	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			02/23/2018 12:00:00 AM			PC Approved	03/03/2018 12:00:00 AM	ADDRESS	34.15889	-118.36851	02/23/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Unit count has been reduced to 13 units. Changes throughout plan set due to unit reduction. There have been lighting revisions to the lobby and Title 24 forms have been updated. *****Previous Work Description*****Plan check for New apartment building 15 units 3 story. Total area: 19871 sq ft. fire alarm variance has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58101	19041-20000-51778	22848 W OXNARD ST	91367	3	177B097   525	2041020008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.17905	-118.625	Plan check for new energy storage system, Energy Storage System size: 13.5KWh, new sub-panel, 1 Energy Storage Device 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58102	14041-10001-27466	8560 W DAY ST	91040	7	204B189   938	2560035028	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/27/2014 12:00:00 AM	ADDRESS	34.25415	-118.31992	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 8.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(32) MODULES: KYOCERA KD255GX-LFB3(2) ABB PVI-5000-OUTD-US-Z-A & PVI-3.0-OUTD-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58103	13041-20000-20757	1680 N VINE ST SUITE 800	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	T24 FOR EXISTING OFFICE SPACE PART OF A HIGH RISE. 2115 SQRFT. SCOPE OF WORK IN SUITE 800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58104	12041-20000-30224	400 S HOPE ST	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM			PC Approved	01/11/2013 12:00:00 AM	ADDRESS	34.05199	-118.25366	Change to lighting in an existing office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for T-24, with Emergency lighting.  Permit Fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58105	17041-10000-09247	9330 W PICO BLVD	90035	5	132A167   226	4306003014	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.05509	-118.39382	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES DUE TO FIRE DAMAGE. TOTAL AFFECTED AREA IS 3174 SQ. FT. B#16016-30000-22131	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58106	18041-20000-44366	624 S GRAND AVE 15th flr	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	05/28/2021 12:00:00 AM	ADDRESS	34.04802	-118.25572	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58107	15041-20000-24891	541 S SPRING ST	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM			PC Approved	08/03/2015 12:00:00 AM	ADDRESS	34.04657	-118.2507	Title 24 plan check only.  Total area = 727 sq. ft.  T.I. to existing commercial bar space.  Lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58108	14041-20001-03819	18638 W HART ST PV1	91335	3	183B121   555	2126019014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	04/18/2014 12:00:00 AM	ADDRESS	34.19755	-118.54005	][][ EXPEDITED PER APPLICANT REQUEST ][][][PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH MAIN SERVICE PANEL. SYSTEM SIZED @ 18.25 kW DC, AND IS TRANSFORMERLESS, WITH (3) POWER ONE INVERTERS; PVI-6000-OUTD-US-A, PVI-5000-OUTD-US-A, PVI-5000-OUTD-US-A, (73) MODULES ET-P660250BB, (1) SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58109	19041-10000-50155	800 N PASEO MIRAMAR	90272	11	129B117    28	4416022039	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	06/23/2020 12:00:00 AM		Permit Finaled	07/21/2020 12:00:00 AM	ADDRESS	34.04968	-118.55753	[EPLAN] INSTALLTING 4 ESS (TESLA POWERWALL), 2 LOAD CENTERS (125A & 400A), 1 200A PANEL CONNECTED TO A 400A MAIN SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58110	18041-10001-14620	1211 S MEYLER ST	90731	15	015B197  1468	7458018027	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	33.73307	-118.29701	07/31/2019Changes to an approved set of plans, changes include the revision of floor layout to reflect field conditions. Permit fees paid under 19041-40000-25975. ___________________________________________________________________________PC FOR OFFICE TI ,Change of use from bakery to office and studio unit at ground level of existing 2-story mixed use building FOR TITLE 24 ENRGY ONLY. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA  1008 SQ.FT (INDOOR AND OUTDOOR).B#18016-40000-10415	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58111	12041-10000-29823	1875 CENTURY PARK EAST suite#-1600& 1700	90067										Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM				Ti in partial 16th & 17th floor of a highrise office Bldg. Suite 1600 all wiring, emergency lights, and exit signs are existing to remain. EPC is for T24 & emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58112	12041-10002-11024	338 S WESTERN AVE F	90020	10	135B193   354	5503003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	ADDRESS	34.06777	-118.30889	((((((((  10-12-12   revised title 24. pc only.)))))))))))))))))))))) CONVERT PORTION OF EXISTING COMMERCIAL BUILDING FROM RETAIL TO MEDICAL OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58113	19041-20002-46461	4821 N OAK PARK AVE	91316	5	168B133   194	2289004011	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM			PC Approved	12/10/2019 12:00:00 AM	ADDRESS	34.1584	-118.50467	$0 plan check fee  due to SB1222 and AB1414supplemental plan check only, for change to approved set, change to site plan, elevation, load calc, and site placard. relocation of service equipments and update to load calc. clouded changes only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58114	19041-10000-40066	5702 N MELVIN AVE	91356	3	174B117   708	2153026034	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Issued	10/22/2019 12:00:00 AM	ADDRESS	34.17456	-118.55988	PLAN CHECK FOR ROOF MOUNTED 13.6KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE6000H-US & SE7600H-US) WITH 39 MODULES USING P400 OPTIMIZERS CONNECTED TO EXISTING 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58115	18041-10000-10619	17915 S FIGUEROA ST	90248	15	063B201   170	7339008002	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.86803	-118.28183	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58116	19041-20000-13458	10170 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Closed	11/22/2019 12:00:00 AM	ADDRESS	34.25528	-118.57964	600A 240/120V 1ph-3w temporary service for backfeed of existing distribution equipment.  Permanent service installation under 19041-20000-13460.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58117	18041-20000-19913	8500 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	PLAN CHECK FOR TITLE 24 ONLY FOR EXISTING COMMERCIAL BUILDING UNDER CANOPY - TOTAL AFFECTED AREA = 5143 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58118	13041-10000-12953	699 W EXPOSITION BLVD	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Info Complete	05/17/2013 12:00:00 AM	ADDRESS	34.01842	-118.28508	13041-10000-12953 TI, title 24 only USC univ.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58119	12041-10004-23829	236 S LOS ANGELES ST	90012	9	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Apartment			11/04/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Closed	03/18/2015 12:00:00 AM	ADDRESS	34.04922	-118.24386	Addition of 10k watts electric water heater and 3.2 k AC.  changes to previously approved set. 11-4-14             Addition of retail distribution section (for future tenant move-in).  (((Construct 176-unit apartment with retail and basement garage. Variance is required to separate the FIRE ALARM plans...  ((((((((((((( VALUE ENGINEERING,    4000 AMPS FEEDER, TO AL.  ALL  METER SECTION TO 80 AMPS , ELEVATION. ETC)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58120	16041-30000-43732	350 S GRAND AVE #2900	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for Title 24 only. Project site is the 29th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 24,880 sq. ft.Note: Building application has been created under 16016-10000-29412	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58121	19041-20000-49364	3820 W ADAMS BLVD	90018	10	123B185   684	5051003003	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.03241	-118.32672	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS. 39 MODULES AND MICROINVERTERS. TOTAL SYSTEM SIZE IS 19.14KWDC AND 18.27KWACFees $36.95 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58122	11041-10000-24612	1530 S OLIVE ST	90015	9	124-5A207 205	5134023006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	09/18/2012 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.03529	-118.26509	First time tenant for a medical center.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58123	17041-10000-14251	2035 N HIGHLAND AVE	90068	4	151-5A185 456	5549029012	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.10759	-118.3376	Interior remodel to auditorium in existing private club. Installing new 1200A 120/208 V service and reconnecting exisitng switchboard to new 1200 A switchboard. (17016-30000-01832)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58124	15041-20000-33464	7080 W HOLLYWOOD BLVD 7TH FLR	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Expired	11/23/2022 12:00:00 AM	ADDRESS	34.10134	-118.34445	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES ON THE 7TH FLOOR. TOTAL AREA IS 12,672 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58125	12041-20000-15129	1075 N WESTERN AVE 114-118	90038	13	144B193   779	5536019024	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			PC Approved	06/28/2012 12:00:00 AM	PIN	34.09038224	-118.30940652	energy plan check wing stop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58126	15041-20000-22990	1451 E 4TH ST	90033	14	127-5A219 339	5172020009	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM			Reviewed by Supervisor	08/25/2015 12:00:00 AM	ADDRESS	34.04249	-118.22532	Plan check for power only.  New 600 A service connected to a new 600 A distribution panel (which will be under seperate permit).  This panel supplies a new 1100 kVA transformer feeding existing 400 panel.  New meters on each distribution panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58127	15041-10001-35832	5210 N LANKERSHIM BLVD	91601	2	171B173  1384	2350018081	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.16634	-118.37406	Adding 7 Devices on Delta-5. <<NEW FIRE ALARM SYSTEM 125 DEVICES.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58128	18041-10000-26255	1302 S LA BREA AVE	90019	10	129B181   660	5070001036	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.04983	-118.34395	PC FOR POWER AND ENERGY FOR TI OF NEW TARGET STORE IN EXISTING SHELL BUILDING. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENTS AND LIGHTING. TOTAL AFFECTED AREA IS 27625 SQ.FTB# 18016-10000-21119	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58129	18041-10001-21104	10845 N GLORIA AVE	91344	12	207B141    72	2667021019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM			PC Approved	06/25/2018 12:00:00 AM	ADDRESS	34.26798	-118.47934	SUPPLEMENTAL PLAN CHECK FOR CHANGE OF MODULE TYPE FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 3.8KVAInstallation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58130	16041-30001-31690	515 S SHATTO PL	90020	13	135B197   842	5077003010	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.0646	-118.29014	Plan check for power and energy place of assembly Max Occ Load: 162, T.I. in existing space 2 story office building. Total area: 18,892 sq ft. Plan Chcek Only, Permit was pulled under: 16041-10000-31690B#16016-30000-09529	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58131	17041-10001-08024	7920 S YORKTOWN AVE	90045	11	099B169   949	4107011021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	33.96569	-118.38936	Supplemental for expedite fees per applicants request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58132	14041-10000-29469	961 W 43RD ST	90037	9	114B197   997	5020034027	[Q]R4-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Apartment			10/23/2014 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Expired	04/05/2018 12:00:00 AM	ADDRESS	34.00559	-118.29043	$0 permit fee is due to State Senate Bill SB-1222.  Installation of new 31.2 kWac rooftop solar array.  120 modules with 12 strings (10 modules per string) connected to 6 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58133	14041-10000-07022	626 W WILSHIRE BLVD SUITE 505	90017	14	129A209    83	5144006025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.04843	-118.25695	PLAN CHECK FOR T24 ENERGY. TOTAL AREA 1293 SQ FT, EMERGENCY LIGHTING. DATA CENTER.Description from building permit with #14016-10000-04847:{{{{T.I. AT SUITE #  505 OF (E) OFFICE BUILDING :	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58134	19041-10000-41986	1515 W 190TH ST #250	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	33.85852	-118.30531	Tenant Improvement in existing office suite #250. Installing Lights. T-24 Energy Only.Affected Area: 7,567 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58135	14041-20000-06230	1050-1052 S FAIRFAX AVE	90019	10	132B177   855	5086001046	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM			PC Approved	03/07/2014 12:00:00 AM	ADDRESS	34.05671	-118.36432	T24 FOR EXISTING RETAIL SPACES. PERMIT HAS BEEN PULLED ON APPLICATION#: 13041-20000-33175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58136	11041-10003-17733	3651 S CRENSHAW BLVD	90016	10	120B185  1493	5046023001	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM			PC Approved	01/20/2012 12:00:00 AM	ADDRESS	34.02122	-118.33541	PLAN CHECK POWER. NEW 600A SERVICE AND EQUIPMENT. EXISTING RETAIL BUILDING INTO DRY CLEANERS WITH ADDITION. NO CHANGE TO LIGHTING.(((((((((((((((((  missing transformer)))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58137	14041-20001-19845	5192 N KNOLLWOOD WAY	91364	3	171B097  1774	2075039001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.16498	-118.61972	Change from previously approved.  Reduce the number of modules and downsize the system size from 4.33KW to 3.8KW.  Note: Permit is under the original application.  Plan check is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(17) TRINA SOLAR TSM-255 MODULES WITH OPTIMIZERS P300 SOLAREDGE(1) SOLAREDGE SE3800 A-US-ZB-U INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58138	19041-20001-32292	8412 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM				10-11-2019 Changes to an approved set of plan, Changes include relocate PV disconnect. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58139	15041-10000-09005	921 S CROCKER ST C-13	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	Energy plan check for a retail T.I . Total area is 1130-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58140	13041-10000-04529	887 N HANLEY AVE	90049	11	138B137   308	4494021026	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01, 2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	04/17/2013 12:00:00 AM	ADDRESS	34.07398	-118.48628	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TRANSFORMERLESS INVERTER, NON STANDARD PLAN. TOTAL SYSTEM SIZE 6KW. 20 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58141	13041-20002-29392	13751 W HUBBARD ST	91342	7	222B153   124	2509014093	QR3-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.30578	-118.43247	(((11/21/2013: THIS IS A PLAN CHECK APPLICATION ONLY. CHANGES MADE TO APPROVED SET OF PLANS. CHANGED INVERTER MANUFACTURER.)))PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 10.6 KW AC USING 36 MODULES. USING 2 CENTRAL TRANSFORMERED INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58142	11041-10000-09036	1000 E 7TH ST	90021	14	126A213   531	5146001001	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Apartment			05/04/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	34.03846	-118.24391	NEW FIRE ALARM FOR REMODELED 6-STORY HOTEL WITH AFFOARDABLE HOUSING UNITS AND OFFICES.   374 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58143	17041-10001-22671	14675 W RINALDI ST E & F	91340	7	213B149   125	2612015011	C2-1-CPIO	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM			PC Approved	10/11/2017 12:00:00 AM	ADDRESS	34.2813	-118.45299	SUPP. PC FOR POWER AND REVISION TO  ENERGY FOR A EYE DOCTOR OFFICE. THIS IS A PLAN CHECK ONLY!!! Title 24 plan check.  T.I. to (E) retail space.  New lighting and receptacles.  Total area = 1,875 sq. ft.       Building permit #17016-10000-17752	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58144	14041-10000-18198	6100 W CENTER DR 8TH FLR	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	33.97733	-118.3922	plancheck for t24 energy.  ti to (e) office space: combine (e) suite 825 and suite 850 into one single suite; 2134 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58145	16041-10000-41432	3654 N BARHAM BLVD BLDG Q	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.13887	-118.34144	PC FOR POWER ONLY, FOR NEW PANELS, STACKED WASHERS & DRYERS IN CERTAIN APT. UNITS IN BUILDING Q OF CAMPUS STYLE COMPLEX. THIS IS BUILDING 2/6(Add 1 laundry ckt to 48 units, and 1 microwave ckt to all 72 units in the building, total 120 new ckt in the building.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58146	09041-10001-13941	8440 W BEVERLY BLVD	90048	5	138B173   494	5511013001	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM			PC Approved	11/10/2010 12:00:00 AM	ADDRESS	34.07579	-118.37464	Revisions to single line diagram--decrease the size of the feeders to th eGTO panel boards,thus reducing thw available short circuit current at the GTO pnals to less than 10KA; change the size of the feeder circuit breakers from 200A to 125Afast food restaurant. one story , power , lighting and title 24.  Ref.#10044-10000-04813.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58147	16041-20000-07385	1757 N BEL-AIR ROAD	90077	5	147B149   108	4370014023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.102	-118.44823	Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (37) AC modules and (1) load center. PV system is interconnecting with a 400-amp split-bus MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58148	16041-10000-14569	1616 W 209TH ST #2	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	PV1 INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A MULTI-FAMILY HOUSE.(6) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58149	17041-20000-37854	3470 S TROUSDALE PKWY wph	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.02202	-118.28393	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58150	16041-10000-05731	1102 W 6TH ST Build-1	90017	1	132A207   306	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.05397	-118.26245	PC FOR POWER ONLY, INSTALLING AN 800 AMP TEMP. POWER POLE WITH FUTURE PROJECTED LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58151	18041-10000-20405	2029 S CENTURY PARK EAST #2060	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	ENERGY PLAN CHECK FOR INTERIOR OFFICE TI LOCATED ON THE 20TH FLOOR OF A HIGHRISE BUILDING. SCOPE INCLUDES NEW LGHTING AND RECEPTACLES. TOTAL AREA IS 888-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58152	19041-10000-23050	810 S FLOWER ST	90017	14	129A209   164	5144020040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	06/09/2020 12:00:00 AM		Permit Finaled	11/02/2020 12:00:00 AM	ADDRESS	34.04692	-118.26018	FULL PC FOR POWER AND ENERGY. TI FOR NEW 7 ELEVEN. CHANGE OF USE FROM OFFICE TO RETAIL. SCOPE INCLUDES NEW 600A PANELBOARD, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 2308 SQ. FT. B#19016-10000-17001	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58153	16041-30000-20834	20265 W HAMLIN ST	91306	3	180B113   355	2134018002	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Expired	07/18/2018 12:00:00 AM	ADDRESS	34.19084	-118.57503	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (26) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58154	16041-10000-04102	5990 N SEPULVEDA BLVD 4TH FLOOR	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.17911	-118.46588	T-24, TI TO A COMMON CORRIDOR ON THE 4TH FLOOR IN AN OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL SQ. F.T 1047.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58155	19041-20000-39924	4151 W PROSPECT AVE	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	09/02/2022 12:00:00 AM		Permit Finaled	05/15/2024 12:00:00 AM	ADDRESS	34.10191	-118.28217	SUBSTATION AND MAIN SWITCHBOARD REPLACEMENT 4000 AMP 4160V SERVICE SIZE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58156	12041-20000-07474	16944 W SAN FERNANDO MISSION BLVD	91344	12	210B133   994	2683028034	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM	04/02/2012 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	ADDRESS	34.2718	-118.50105	change of ATM  lightingEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58157	14041-20000-00740	7906 N MELITA AVE	91605	2	189B157   615	2303012017	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.21358	-118.4195	nEW 8.5KW ROOFTOP PV SYSTEM for an existing single family dwelling.  System is UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58158	16041-20002-13694	5144 N LANKERSHIM BLVD	91601	2	171B173   725	2353005016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.16426	-118.37406	07/19/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 compliance certificates. 01/18/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to theater. Total lighting area = 3,045 sq. ft.Note: Building permit has been pulled under 16016-20000-00252*****Previous Work Description*****New power receptacles, new branch circuits, and restrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58159	15041-10000-03981	2939 S VINEYARD AVE	90016	10	120B181    97	5057016024	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.02866	-118.34654	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERECONNECT WITH MAIN SERVICE PANEL.(12) MODULES: YINGLI YL250P-29B(1) INVERTER: ABB # PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58160	12041-20000-29907	10250 W SANTA MONICA BLVD FC-11	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM			PC Approved	12/12/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	Plan check for energy and emergency lighting. Renovation of a restaurant space within a mall. Massis Kabob. Space FC-11. 937sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58161	19041-20002-00589	9432 N FARRALONE AVE pv1	91311	12	198B101   108	2727019018	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.2418	-118.61024	02/01/2019 Changes to an approved set of plans. Changes have been made to reflect field installation.*****Previous Work Description*****Revisions to approved set of plans.  Miscellaneous equipment rating and wiring detail changes.  PV system size details unchanged.  (((pv1install roof mounted pv system sized 13.5KW AC interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58162	19041-10000-45251	3463 S BARRY AVE	90066	11	117B157   868	4249018006	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.01392	-118.43104	NOTE: FEES ARE $0 DUE TO AB 1414.[EPLAN] NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 11.34KW DC/ 10 KW AC, WITH A CENTRAL INVERTER OF 10KW (SE10000H), 36 MODULES ( HANWHA Q-CELLS), 2 TESLA  ESS AC POWERWALL  AND 36 POWR OPTIMIZERS (P400).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58163	19041-20000-40242	5372 E OAKLAND ST	90032	14	144A237   175	5219005004	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.08912	-118.16444	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTNG SFD. SYSTEM SIZE IS 3.72KW DC/3.8KW AC. SCOPE OF WORK CONSISTS OF (12) PV MODULES WITH OPTIMIZERS AND A 3.8 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58164	15041-10001-01467	10243 N HAYVENHURST AVE	91343	12	204B137   368	2685015016	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	02/19/2015 12:00:00 AM	ADDRESS	34.2569	-118.49377	Supplemental application for expedite fees.Installation of new roof mounted solar PV system.  7.75 kW microinverter system consisting of 31 250 W modules (2 strings)  Applicant tried to pull permit online but couldn't.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58165	14041-20000-16487	12659 N DORINA PL	91344	12	219B133    32	2602019008	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Expired	08/11/2016 12:00:00 AM	ADDRESS	34.30095	-118.50533	PV1.  NEW 6KW AC ROOF-MOUNTED PV SYSTEM USING TRANSFORMERLESS INVERTER. 24 MODULES TOTAL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58166	13041-10000-33010	16528 W PLUMMER ST	91343	12	198B137    74	2676001008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.24275	-118.4926	PV1, Install 3.75 kw DC roof-mounted photovoltaic system interconnect with the main service panel.(1)Transformerless inverter(s): SolarEdge SE3800A-US. (15) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58167	13041-10000-06084	5433 N ROYER AVE	91367	3	174B097   915	2042007039	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2013 12:00:00 AM			Reviewed by Supervisor	03/19/2013 12:00:00 AM	ADDRESS	34.16927	-118.62786	PV1 FOR SINGLE STORY HOUSE.  {44 MODULES: TSM-240 PC/PA05} {CENTRAL INVERTER: PVI-3.8-I-OUTD-US}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58168	13041-10000-21408	515 S FIGUEROA ST SUITE 1410	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.05199	-118.25764	TITLE 24 PLAN CHECK ONLY. 1240 SQFT. EMERGENCY LIGHTING. HIGH RISE.  WORK ON 14TH FLOOR. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58169	18041-10000-39474	444 S FLOWER ST 38TH FLR.	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLNA CHECK FOR T24 ONLY, TI ON RESTROOM, ELEVATOR LOBBY & CORRIDOR RENOVATION, NEW PLUMBING, NEW LIGHTING, AND NEW FINISHES. SCOPE LOCATED ON THE 38TH FLOOR. TOTAL AREA: 2,238 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58170	16041-10002-13248	350 S GRAND AVE Floors 46-50	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	PIN	34.05160512	-118.25169569	02/09/2018Restamp drawing for lost set per nabil.  Master scope of work : TI to (E) commercial office highrise building tenant spaces.  Floors 46 thru 50.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58171	18041-20000-26119	145 S DOHENY DR	90048	5	138B169   497	4335007036	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.07395	-118.39001	Plan check for a PV2 roof-mounted PV system. System size is 43.89 kWdc/37.86 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (114) modules.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58172	16041-10000-40323	2413 S WALKER AVE	90731	15	009B193   226	7460017016	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2973.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	33.72211	-118.30363	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 1950 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58173	14041-10001-19548	1900 S MAIN ST	90011	9	123A207   167	5127025026	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	PIN	34.03059603	-118.26451342	Addition of 75 kVA transformer to reduce available fault current at equipment.  Plan check for power. (((Install (1) 80KW 480/277 Volt Generator. Install (1) 100/3 and (1) 260/3 Automatic Transfer Switches. (NO LOAD CHANGES))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58174	19041-10000-51281	3000 S THATCHER AVE	90292	11	108B149  1608	4229007066	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM			Reviewed by Supervisor	01/07/2020 12:00:00 AM	ADDRESS	33.98839	-118.44986	(E-PLAN) NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 12 MODULES (Q.PEAK DUO BLK-G5 315W), 1 CENTRAL INVERTER (SOLIVIA 5.2), 1 ENERGY STORAGE SYSTEM, AND 1 PANEL OF 125 AMPSSYSTEM SIZE: 3.78 KW DC; 5.2 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58175	16041-10000-38993	10250 W SANTA MONICA BLVD 2705	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR NEW RETAIL TENANT. POWER AND ENERGY. SCOPE INCLUDES NEW 2500A DIST. BOARD (480/277 3PH), NEW PANELS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA IS 44523 SQ.FT. INDOOR AND 7426 SQ.FT OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58176	17041-20000-31977	568 N CHAUTAUQUA BLVD	90272	11	126B129   850	4411016008	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM			PC Info Complete	06/27/2018 12:00:00 AM	ADDRESS	34.03779	-118.51825	Plan check for power only. Project site is a new 2-story single-family dwelling over a basement garage.Note: Building application has been generated under 16010-20000-04270	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58177	15041-10000-07475	10000 W SANTA MONICA BLVD 1-283	90067	5	135B161    35	4319001001	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Apartment			03/13/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.06351	-118.41446	New fire alarm system for 43-story apartment building with B and R1 occupancies over 3 stories of subterranean parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58178	14041-20000-00836	1102 W 6TH ST	90017	1	132A207   306	5143024011	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.05397	-118.26245	New 606 Unit mixed use apartment/commercial building.  350,000 sq. ft, with three 3,000 amp services.  <<Engineer to verify fees for FINAL.>>  Variance to separate fire alarm has been paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58179	16041-10011-25972	200-300 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	PLAN CHECK AND RESTAMP FOR 160410-30010-25972 PERMIT NUMBER. RESTAMP RTI AND PULL PERMITS UNDER THAT NUMBER. RECHECKING FOR LOST SET ONLY AND RESTAMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58180	18041-10000-10387	801 S OLIVE ST #A	90014	14	127-5A209  31	5144019026	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.04514	-118.25715	FIRST TENANT IMPROVEMENT FOR NEW STARBUCKS COFFEE SHOP IN NEW TENANT SPACE.B#18016-10000-08345	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58181	15041-20002-11356	23517 W WINDOM ST	91304	12	186B093   259	2027036025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	ADDRESS	34.20651	-118.64078	"5.7.2015 - Changes to approved set. Change pv source circuit conduit sizes to 3/4"". Change PV subpanel feeder to #2 and conduit to 1"". These changes ONLY.[PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 16.35 KW DC]"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58182	14041-20001-04053	20244 W VIA GALILEO	91326	12	219B113   173	2701043009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.29486	-118.57509	Expedite Fee ONLY****Install new roof mounted PV system with 6.25KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58183	15041-20001-02389	14340 W GRAMMAR PL	91402	6	192B153   126	2638020001	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.22605	-118.44551	Fee for expedite only.Roof mounted PV system total 6KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58184	12041-10000-20212	1517 N FOREST KNOLL DR	90069	5	147B169   601	5558009031	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.09839	-118.38032	Plan check for new 11.76KW roof mounted photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58185	14041-20001-32050	22441 W HARTLAND ST	91307	12	183B101   703	2024029010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.19474	-118.61627	EXPEDITE PER APPLICANT REQUEST[PV1Install roof-mounted solar array on SFD. Interconnect with 200A MSP. Derating main breaker to 150A.System size: 12.5kW (7.5+5). Grounded system.48 250W pv modules across 5 strings (inv1: 10 and 10+10 combined. inv2: 9+9).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58186	17041-10000-22528	304 S BROADWAY #400	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM			PC Info Complete	07/10/2017 12:00:00 AM	ADDRESS	34.05076	-118.248	Plan check for Title 24.  T.I. to existing office space.  All subpanels to remain existing with new lighting and receptacles.  Total area = 2,923 sq. ft.       Building permit #17016-10000-14348ELECTRICAL PERMIT ALREADY ISSUED UNDER 17041-40000-21419THIS APP IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58187	10041-10000-17434	2920 S SEPULVEDA BLVD	90064	5	120B157   121	4251003012	C2-1VL, R4P-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	07/18/2011 12:00:00 AM	ADDRESS	34.02823	-118.42906	Install a new Fire Alarm System in a 3 story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58188	18041-10000-20335	6505 S ESPLANADE #2	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	04/01/2021 12:00:00 AM	ADDRESS	33.96159	-118.45071	PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW LOAD CENTER, 6 MODULES(#SC325) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 1.95KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58189	19041-10003-23931	220 W 109TH PL	90061	8	088-5A203 205	6074014034	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM			Corrections Issued	01/28/2020 12:00:00 AM	ADDRESS	33.93642	-118.27696	Changes on approved set. Adding a 100A subpanel. Address delta 3 changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58190	13041-20001-33082	1550 N EL CENTRO AVE	90028	13	148-5A189 331	5546026024	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.09961	-118.32359	CHANGE TO APPROVED SET OF PLANS. ADDITION OF A COUPLE NEW PANELS, UPGRADE TRANSFORMERS AND UPPER LEVELS, AND RELOCATION OF SOME LOADS. PLAN CHECK FOR POWER SYSTEM CHANGES. ALL CHANGES HAVE BEEN NOTED DELTA 3 AND DELTA 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58191	19041-20000-19113	5900 W WILSHIRE BLVD 24TH FLR-25TH FLR	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	TI to (E) commercial highrise office building tenant on 24th and 25th floors.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58192	13041-10000-22845	707 W WILSHIRE BLVD FLOOR 39	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.04893	-118.2572	TITLE 24 PLAN CHECK ONLY. HIGH RISE. EMERGENCY LIGHTING. 3899 SQFT.  PERMIT WAS PREVIOUSLY ACQUIRED UNDER APP 13041-10000-20695.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58193	17041-10000-21038	19831 W NORDHOFF PL Unit 116	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.23691	-118.56541	Title 24 plan check.  Remove metal halide fixture and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58194	17041-10000-28243	403 N CENTRE ST	90731	15	018B201   356	7449009015	R2-1XL	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Expired	10/10/2023 12:00:00 AM	ADDRESS	33.74618	-118.28363	Note: Permit Fees are $0 due to senate bill 1222.PV1, new solar system on existing residential roof-top. Total system size is 3.25 KWdc/3.00KWac PV ARRAY. +13.5 kwh ENERGY STORAGE SYSTEM. using 5.8kw battery system and 10 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58195	13041-10000-32691	14800 S FIGUEROA ST	90248	15	075B201   141	6129001046	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			Reviewed by Supervisor	12/30/2013 12:00:00 AM	ADDRESS	33.89809	-118.28288	POWER TO SOLAR STEEL FURNACE. pc for power only.; HAZARDOUS.  (plan check per inspector request).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58196	17041-10000-28362	830 S FRANCISCO ST	90017	14	129A207   124	5144022035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Issued	08/11/2017 12:00:00 AM	ADDRESS	34.04791	-118.26328	PC for T24 for removal 25 of metal halide fixture and replace with new LED fixtures for outdoor use. Total affected area is 61900 Sq. Ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58197	12041-10000-15409	6801 W HOLLYWOOD BLVD #321	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	T.I. OF EXISTING RETAIL SPACE INCLUDING DOORS, PARTITIONS, CEILING, FIXTURES AND FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58198	13041-20001-14229	2701 S BROADWAY	90007	9	120A205    69	5122002016	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/17/2013 12:00:00 AM	ADDRESS	34.02427	-118.27073	((7/17/2013: CHANGES MADE TO APPROVED SET OF PLANS. ADDED MORE LIGHTS AND CHANGED POSITIONING OF OTHERS.))Change to lighting and receptacles to an existing retail store.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58199	19041-10000-40750	8501 N OSO AVE	91306	3	192B113   203	2781012011	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM			Corrections Issued	10/08/2019 12:00:00 AM	ADDRESS	34.22484	-118.57554	VOID ( LOST MARKED UP SET, SUBMITTED FOR RE-PLAN CHECK UNDER SEPERATE APPLICATION)PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER WITH 16 MODULES USING P320 OPTIMIZERS CONNECTED TO EXISTING 100 SERVICESYSTEM SIZE IS 3.8KWac AND 4.960KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58200	13041-10000-08168	8655 S SEPULVEDA BLVD	90045	11	096B165   768	4122001003	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	07/21/2013 12:00:00 AM	ADDRESS	33.95844	-118.39645	NEW FIRE ALARM SYSTEM FOR EXISTING RETAIL SPACE. 1 FIRE ALARM PANEL AND 9 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58201	16041-20000-19157	13025 W MOORPARK ST	91604	2	165B161   275	2362011030	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial	5	Apartment	06/01/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.1505	-118.41688	Plan check for PV roof mounted system. System size: 3.8kW with 12 modules and 1 inverter(3.8kw)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58202	18041-10000-32937	1215 N LODI PL	90038	13	144B189   280	5534003017	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM			PC Approved	08/28/2018 12:00:00 AM	ADDRESS	34.09297	-118.3235	TENANT IMPROVEMENT TO EXISTING CLUB AND HOTEL (YWCA). T-24 Energy Only in the Guest Room on the First Floor.BLDG PERMIT: 18016-10000-26805	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58203	15041-10000-31864	6430 W SUNSET BLVD 1ST FLOOR	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.09782	-118.32979	Energy plan check for a change of use from office to coffee shop; Scope includes new lighting, receptalce, and equipment; Total area is 1994-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58204	19041-20000-24686	21800 W OXNARD ST ste 650	91367	3	177B105    81	2146006046	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.17898	-118.60253	ti to an existing commercial building (high rise) adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58205	18041-10000-49144	14931 W MCKENDREE AVE	90272	11	129B129    69	4422012014	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.05272	-118.52255	PC FOR PV AND ENERGY STORAGE SYSTEM. SCOPE INCLUDE  (MODEL: TESLA  AC POWERWALL 2.0) CAPACITY 27KWH STORAGE SYSTEM. NEW 200A LOAD CENTER.  NEW 31 PV MODULES (HANWHA Q-CELLS #Q.PEAK-G4.1/SC305), INVERTER SOLIVIA 7.6 TL.$0 permit fee due to senate bill 1222, AB1414,	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58206	12041-10000-03146	333 S ALAMEDA ST	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM			Corrections Issued	02/18/2012 12:00:00 AM	ADDRESS	34.04448	-118.23824	full plan check per owners request, title 24 and emergency lighting, 5 new panel , arcade, restaurant, bowling. must use area catagory. plann check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58207	11041-10000-15587	1300-1336 W ANGELINA ST	90026	1	135A209   152	5160010001		Central			YES	2080.00	Electrical	Electrical	Apartment			07/26/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	PIN	34.06461647	-118.25616529	TI TO AN EXISTING APARTMENT COMPLEX.  NO NEW PANELS AND NO NEW LOAD, PER APPLICANT.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58208	18041-10000-18046	15309 W ANTIOCH ST	90272	11	129B125   555	4412002012	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Info Complete	09/13/2018 12:00:00 AM	ADDRESS	34.04716	-118.52658	PC FOR INTERIOR TI FOR (E) RETAIL SPACE.SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS. TOTAL AFFECTECD AREA  1432 SQ.FT  (USING TAILORED METHOD). B# 18016-30000-14869	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58209	12041-20000-24014	1126 S SANTEE ST 101-106	90015	9	124-5A209  41	5145022004	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.03702	-118.25659	Express permit for 36 circuits and 4 new panels. Plan check for energy and emergency lighting. 1st floor. 6256sqft.Units 101-106INTERIOR T.I.  TO (E) FIRST FLOOR OF   ( E) 3 STORY   RETAIL BUILDING: REMOVE  (E) FISRT FLOOR   NON BEARING WALLS & ADD NEW DEMISING  WALLS TO  CREATE  7  TENANT SPACES  & ADD. NEW  STAIRS CASE  FROM FIRST FLOOR TO (E) 2ND FLOOR  & MODIFY  (E)  FIRST FLOOR  TWO BRACE FRAMES &  ONE MOMENT FRAME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58210	14041-10001-10850	321 N LARCHMONT BLVD SUITE 1010	90004	4	138B189   330	5523020038	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.07682	-118.32384	[[[6/18/14   , CHANGES TO APPROVED SET OF PLANS. PLANCHECK ONLY. SHOW EMERGENCY CIRCUIT AND PANEL/ EMERGENCY GENERATION CONNECTION ON SINGLE LINE PLANS.DELTA 2 CHANGES ONLY. WORK IS ON SUITE 1010.PLAN CHECK FOR POWER AND ENERGY OF EXISTING DENTIST TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58211	11041-10000-21803	11620 W WILSHIRE BLVD ste 200	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.05021	-118.45963	T. I. in existing medical office, lighting and power.   The space is subject ot article CEC 517, full plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58212	10041-20000-22134	11651 W SHERMAN WAY	91605	6	183B169   112	2316030006	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	01/28/2011 12:00:00 AM	ADDRESS	34.20136	-118.38621	Plan check for new installation of 800A service, switchboard, and new panel for new tenant. All loads are existing to remain. Loads for new tenant will be on seperate application (future).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58213	13041-10000-28788	20706 W SKOURAS DR	91306	3	180B109   159	2148010001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	10/28/2013 12:00:00 AM	ADDRESS	34.1924	-118.58415	PV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. STANDARD CENTRAL INVERTER PLAN. SYSTEM SIZE: 9.75 kW DC.(39) TRINA SOLAR # TSM-250P(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58214	16041-10001-14986	11900 N BALBOA BLVD	91344	12	216B133   483	2610002051	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM			PC Approved	10/14/2016 12:00:00 AM	ADDRESS	34.28642	-118.50125	PLAN CHECK FOR RELOCATION OF CAR CHARGING UNITS. NEW LOCATION OK WITH GREEN DIVISION. CHANGES CLOUDED. SINGLE PAGE ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58215	18041-10000-13051	21512 W VICTORY BLVD	91367	3	180B105    57	2146005186	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.18783	-118.59946	NEW RESTAURANT. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58216	10041-10001-20802	1100 S GLENDON AVE STE 2000	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	REVISED PERMITTED SET OF PLANS- NEW PANEL BOARDS AND CKTS AND SMALL CHANGES TO THE LIGHTING PLANS-NO CHANGES TO THE QUANTITY OF LUMINAIRES((((((((((FULL FLOOR T.I. TO CREATE OFFICES, CONFERENCE ROOM AND RECEPTION. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58217	14041-10000-09459	1061 S OXFORD AVE	90006	10	129B193   601	5080009026	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			04/09/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.05104	-118.30766	plan check for power and energy. Methane Buffer Zone. BLDG#14010.10.00391:  5-STORY APARTMENT BUILDING WITH PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58218	13041-20001-10434	14864 W NURMI ST PV1	91342	7	222B149   892	2506009001	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.30261	-118.45654	((SUPPLEMENTAL APPLICATION FOR PC ONLY. CHANGE OF INVERTER REQUIRES PLAN CHECK. PC ONLY FOR PV1 SINGLE FAMILY DWELLING. TRANSFORMERLESS INVERTER. PERMIT ALREADY ISSUED FROM ORIGINAL APPLICATION)))INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 4.40 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58219	11041-10003-10270	14049 W VENTURA BLVD	91423	4	165B153   351	2271014014	[T][Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM			PC Info Complete	01/10/2014 12:00:00 AM	ADDRESS	34.14947	-118.43885	CHANGES TO APPROVED SET OF PLANS. CHANGES ARE CLOUDED.  ADDITION OF CKTS AND EQUIPMENT.FROM ORIGINAL PC:NEW RALPHS WITH PARKING LOT.  EVERYTHING IS NEW.  REGULAR PLAN CHECK.  NOTE TO PLAN CHECKER:  CLIENT BROUGHT A PRE-CUT CHECK.. ACTUAL FEES ARE MORE THAN THE AMOUNT PAID.  VERIFY FEES DURING PLAN CHECK PROCESS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58220	14041-10000-08149	5006 S WESTERN AVE	90062	8	111B193  1128	5016036035	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			PC Info Complete	06/23/2014 12:00:00 AM	ADDRESS	33.99801	-118.30876	SERVICE UPGRADE FOR MIXED USE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58221	14041-10000-10646	1129 W WASHINGTON BLVD	90015	1	126A201   198	5135015031	[Q]C2-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.03905	-118.28192	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58222	19041-10000-23239	2420 N DALY ST	90031	1	139-5A221 308	5204012010	PF-1-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.07442	-118.21547	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58223	14041-20000-05449	10889 W VINEDALE ST	91352	6	195B173   536	2408009043	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.22782	-118.36821	Roof mounted PV system with Microinverter (Model M215-60-2LL), system size 2.16KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58224	13041-20000-20126	17010 W GLEDHILL ST	91325	12	198B133   110	2692022038	RE9-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2013 12:00:00 AM			Corrections Issued	07/29/2013 12:00:00 AM	ADDRESS	34.24224	-118.50295	New Enphase Micro-inverter PV system for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58225	08041-10001-08497	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Public Safety Only			04/13/2011 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	PIN	33.94363002	-118.42513364	Change the approved plan for LAX FEDEX office Fire Alarm. Addition of  33 devices. (((((((((((((((((((((EPC installation of new alarm sytem for FEDEX office buiding and hangar.)))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58226	18041-20001-29348	22408 W SOUTH SUMMIT RIDGE CIR	91311	12	198B101   220	2727022030	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM			PC Approved	08/12/2018 12:00:00 AM	ADDRESS	34.24008	-118.61499	Expedite per applicant requestPV1.  Install 15.4 kW roof mounted grid tied PV system.  (44) modules with (2) 7.6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58227	10041-20000-18723	7217 N GEYSER AVE 1-5	91335	3	183B121    48	2118025006	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	12/15/2010 12:00:00 AM	ADDRESS	34.20173	-118.54275	Plan check T-24 Energy (general/emergency) lighting for office TI. Indoor and outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58228	15041-20000-18432	649 W ADAMS BLVD	90007	1	123A203   204	5124026013	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Issued	06/19/2015 12:00:00 AM	ADDRESS	34.02895	-118.27743	Plan check for Title 24 only for 2 class room and an office school building. Total area: 6,823 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58229	17041-10001-24768	4950 W SUNSET BLVD	90027	13	147B197   751	5543022015	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			PC Info Complete	11/17/2017 12:00:00 AM	ADDRESS	34.09786	-118.29745	Changes to approved set.  Installing 30 amp receptacles to connect with computer consul.  Installation complies with nec 210.21(B)  (1) . Delta C changes>>>>>>>EQUIPEMENT REPLACEMENT IN MEDICAL OFFICE BUILDING. PROVIDING UPDATED LIGHTING, T24 AND SOME MEDICAL EQUIPEMENT. PC FOR POWER AND ENERGY. PATIENT ARE AREA.<<<<	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58230	13041-20000-19026	12118 N ROSSITER AVE PV-1	91342	7	216B149   252	2611017012	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	07/31/2013 12:00:00 AM	ADDRESS	34.29035	-118.45496	PV-1. Microinverter for SFD. 24 modules for 5160W AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58231	12041-10000-08104	17546 W SEPTO ST	91325	12	201B129    37	2734020005	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.25117	-118.51725	New 7.92KW roof mounted photovoltaic system for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58232	17041-10000-40202	11000 W VICTORY BLVD	91606	2	180B173   886	2336020036	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.18651	-118.37057	EXTERIOR & INTERIOR TI - DINNING ROOM/RESTROOM etc.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58233	17041-20001-18643	4534 N VAN NOORD AVE	91604	4	168B161  1071	2362006005	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.15323	-118.41483	Revisions to approved set of plans.  Removal of derated main breaker from plan design.  Change of feeder rating for critical load backup panel.  (((installation of new powerwall 5kw (battery back up) to an existing pv system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58234	14041-10000-18092	11820 W STANWOOD DR	90066	11	117B153   275	4250002011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Expired	08/10/2016 12:00:00 AM	ADDRESS	34.01922	-118.43814	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {PVI-3.6-OUTD-US }]. [(18)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58235	19041-10000-51950	7241 N HINDS AVE	91605	2	186B169   972	2317019036	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.20235	-118.39119	PLAN CHECK FOR A FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES 1 CONTROL PANEL AND 6 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58236	13041-20000-02005	19800 W GREENBRIAR DR	91356	3	162B117    40	2180001008	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	03/27/2013 12:00:00 AM	ADDRESS	34.144	-118.56424	Photovoltaic system on roof of accessory building, used as office, to single family dwelling, with existing subpanel supplied from the main service located at the residence.  Inspector to verify grounding and disconnect for existing subpanel at the accessory building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58237	17041-10003-37851	1129 N MONUMENT ST	90272	11	129B125   390	4423001039	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.0497	-118.52498	"DELTA ""1"" CHANGES TO APPROVED PLANS.<<<PV1, NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH TWO 5.8KVA/13.5KWH POWERWALL STORAGE BATTERIES. TOTAL SYSTEM SIZE IS12.025KWdc / 10.00KWac.(37)MODULES-SOLARCITY STANDARD #SC325(37)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE10000A-US-ZB-U(2)AC POWERWALL 5.8KW>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58238	19041-10001-17189	17263 W VANOWEN ST	91406	6	183B133   936	2230001012	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.19403	-118.5093	exepdite suppl for pv2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58239	19041-10000-05762	15580 W ROXFORD ST	91342	7	225B145   307	2501004022	[T][Q]M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	34.31177	-118.47087	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58240	13041-20000-01153	2449 N ANGELO DR	90077	5	153B153   128	4382029***	OS-1XL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	34.11393	-118.44397	Photovoltaic system using enphase M215 inverters on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58241	17041-10000-07211	11954 W SANTA MONICA BLVD	90025	11	126B145   601	4263035031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.04117	-118.46147	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 12300 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58242	15041-10000-24119	5110 S CRENSHAW BLVD 1-32	90043	8	111B185   573	5013019035	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Apartment			07/28/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	33.99629	-118.33046	NEW FIRE ALARM SYSTEM 161 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58243	15041-20000-42582	8525 N HAYVENHURST AVE	91343	12	192B137   110	2689014003	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.22574	-118.49406	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (45) modules, (2) combiner boxes, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58244	18041-10001-22630	11439 N ENCINO AVE	91344	12	213B129   333	2711022027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM			PC Approved	07/10/2018 12:00:00 AM	ADDRESS	34.27848	-118.51547	EXPEDITE PER APPLICANT REQUEST. (((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 42.24KWdc / 50.0KWac.(128)MODULES-CANADIAN SOLAR CS6U-330M(1)INVERTER-SMA SUNNY TRIPOWER CORE1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58245	13041-10000-05071	8242-8248 N SEPULVEDA PL 1-17	91402	6	192B145   452	2209001006	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	Apartment			02/27/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM				PLAN CHECK FOR POWER AND ENERGY FOR NEW 17 UNIT APARTMENT BUILDING.  TWO HABITABLE FLOORS AND A GARAGE ON GRADE. (THREE STORY BUILDING).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58246	14041-20000-05275	20902 W AVENUE SAN LUIS	91364	3	171B109   181	2167021007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.16451	-118.58862	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWAC. USING SOLAR OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58247	10041-20000-10259	888 S FIGUEROA ST 12TH &14TH-FLOOR	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/01/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	02/27/2012 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI WORK IN 14TH FLOOR AND PORTION OF 12TH FLOOOR. THIS P/C IS TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58248	10041-20003-24911	1600 E 4TH ST	90033	14	127-5A219 328	5171001907	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Public Safety Only			03/23/2011 12:00:00 AM			PC Approved	03/23/2011 12:00:00 AM	ADDRESS	34.04276	-118.22252	PLAN CHECK ONLY REVISE PLAN TO SHOW CORRECTED ADDRESS ON TITLE BLOCK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58249	12041-10000-10606	3620 S VERMONT AVE	90089	9	120B197   929	5039002030	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM			PC Approved	05/09/2012 12:00:00 AM	ADDRESS	34.02213	-118.29133	Plan check for T24 Energy mandatory measures for USC KAP Classroom remodel #134, 140, 144, 146, 147, 148, 150, 156, 148, and 164. No new lighting installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58250	17041-20001-00682	550 E SAN JUAN AVE	90291	11	108B145   842	4239026037	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	02/01/2017 12:00:00 AM	ADDRESS	33.99275	-118.46766	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 24.1 kWac and consists of (67) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58251	13041-20001-35450	14823 W LASSEN ST	91345	7	201B149   182	2647010018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	ADDRESS	34.2501	-118.45506	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. SOLAR EDGE. TOTAL SYSTEM SIZE 5KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58252	19041-20000-18517	4152 N FALLING LEAF DR	91316	5	165B125   353	2184032032	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.14618	-118.52522	PV1.  Install 21.6 kW roof mounted grid tied PV system.  (60) AC modules connected to 400A Panel Fees $47.59 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58253	15041-20000-20751	21650 W OXNARD ST suite 1440	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	TI energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58254	14041-20000-35060	7918 N CRANER AVE	91352	2	189B173   374	2409005018	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.21443	-118.36911	PV1. INSTALL ROOF MOUNTED P V SYSTEM SIZED 7.0KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(22) SUNPOWER 327W MODULES(1) SMA SB7000TL INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58255	14041-10001-06216	15066 W SUTTON ST	91403	4	166-5A147 216	2276024003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	03/15/2014 12:00:00 AM	ADDRESS	34.14911	-118.46214	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL .5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(21) MODULES: TRINA SOLAR TSM-250PAO5.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58256	15041-10000-01249	5959 W CENTURY BLVD STE 900	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	33.94571	-118.38857	Energy plan check for an office TI in a high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58257	10041-10001-24522	6090 W PICO BLVD	90035	10	129B173   245	5068002001	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Finaled	05/24/2011 12:00:00 AM	ADDRESS	34.05263	-118.37368	INSTALLATION OF NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58258	17041-10000-14397	3056 W LEEWARD AVE	90005	1	132B197   369	5077018900	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.05856	-118.29073	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new led ones. Area: 6,575 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58259	16041-10001-12204	11835 W OLYMPIC BLVD EAST TOWER-200E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.03301	-118.45119	TI to an (E) office build. Ste. # 200E. Install new lights and control receptacles. This is PC only for T-24. Permit under 16041-40000-12204.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58260	13041-10000-09237	13488 W MAXELLA AVE	90292		105B153    77	4212004032							Electrical	Electrical	Apartment			04/10/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	PV2 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 10.080 KW DC.  42 MODULES IN 6 STRINGS. USING 3 INVERTERS (2 STRINGS PER INVERTER). [MODULE: LUMOS LSX240 |||| INVERTER: AURORA # PVI-3.0-OUTD-US] PERMIT WAS PULLED UNDER APPLICATION NUMBER 13041-10000-02144.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58261	10041-20000-25895	5601 N DE SOTO AVE 4th floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	T.I. for Kaiser Foundation in Infusion room.  Install subpanels, branch circuits, and lighting.  Plan for power and energy.  Note:  T-24 compliance forms will be submitted next week by the applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58262	13041-10000-12573	7741 N HAYVENHURST AVE	91406	6	189B137   121	2205009090	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/16/2013 12:00:00 AM	ADDRESS	34.21152	-118.49265	tITLE 24 AND ENERGY LIGHTINF FOR A RESTRURANT, GYM , TWO STORY, AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58263	19041-10000-34361	5719 S MESMER AVE BLD 2	90230	11	105B165   424	4220014044	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Approved	01/31/2020 12:00:00 AM	ADDRESS	33.98439	-118.3997	PLAN CHECK ONLY FOR T24 ONLY, SCOPE WORK INCLUDES NEW LIGHITNG, CIRCUITS, AND CONTROLS TOTAL AFFECTED AREA IS 9209 SQFT. ALL PERMIT FEES WILL BE UNDER 19041-10001-34361	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58264	16041-10001-11963	10250 W SANTA MONICA BLVD STE 195	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	ADDRESS	34.05949	-118.42045	CHANGES TO AN APPROVED SET - UPDATING LOAD ON PANEL FOR OUTDOOR HEATERS (DELTA 3 CHANGES) - CHANGE CIRCUIT BREAKERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58265	13041-10001-33024	139 S LAYTON DR	90049	11	135B145   274	4365004020	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.06823	-118.46894	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 5 KW. TRANSFORMERED, NEGATIVELY GROUNDED SYSTEM.(20) YNGLI YL250(20) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58266	17041-20000-39771	4364 S MCLAUGHLIN AVE	90066	11	111B161   643	4217009018	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	33.9991	-118.41557	INSTALLATION OF FIRE ALARM SYSTEM. 1 FACP AND 56 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58267	11041-10000-24287	700 W WORLD WAY Terminal 7-Unit 7A	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	T.I. work to LAX Terminal 7, Unit 7A.   Per applicant this is NOT a first time tenant and is an EXISTING space.  Plan check for T-24 is 11041-1000024287	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58268	14041-20000-24876	7014 S HOOVER ST UNIT 1	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 1.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58269	15041-10000-27827	3758 N LANKERSHIM BLVD	90068	4	162B177   574	2380001044	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/24/2015 12:00:00 AM	ADDRESS	34.13639	-118.36438	PV 1, single family home. (1) SMA America SB6000TL  inverter, and (20) Sunpower SPR-345 modules inter connecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58270	12041-10001-30004	380 W WORLD WAY level 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Approved	03/05/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	chnages to previuosly approved set. delta 1Recalculate fees since applicant brought check. (11->13 branch circuits)FULL POWER AND ENERGY. LAX. storage for the DUTY-FREE shops. 1ST TIME TENANT.  Located on level 4 back of the house. Methane. Separate fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58271	16041-10000-07578	6033 S CENTRAL AVE	90001	9	105B209    92	6007007022	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	33.98492	-118.25673	PV2 ROOF MOUNTED 3PHASE SYSTEM. TOTAL SYSTEM SIZE 138KWac. Feed In Tariff System(611) MODULES-SOLARWORLD SW 260 POLY(7) INVERTERS-SOLECTRIA CPS SC23KTL-DO/US-480(1) SUBPANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58272	15041-10000-03507	726 N LA BREA AVE	90038	5	141B181   449	5525008040	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Refund in Progress	10/06/2015 12:00:00 AM	ADDRESS	34.08425	-118.34386	Title 24 plan check only.  Total area = 2,914 sq. ft.Remove HID lights and replace with LED light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58273	12041-10000-22512	3321 S MCLAUGHLIN AVE	90066	11	117B153   519	4249008011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.01767	-118.43396	NEW 6.24KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58274	11041-10000-24586	10921 W WILSHIRE BLVD	90024	5	132B153   344	4363023032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM			PC Approved	11/16/2011 12:00:00 AM	ADDRESS	34.05881	-118.44477	INSTALLATION OF AN EMERGENCY TRANSFER SWITCH TO TRANSFER POWER FROM EMEGERNCY GENERATOR TO THE ELEVATOR DISTRIBUTION BOARD IN ORDER FOR ONE ELEVATOR (60KW0 WILL BE ENERGIZED IN EMERGENCY MODE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58275	17041-20000-15064	2947 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.03802	-118.20335	Plan check for a PV2 roof-mounted PV system. System size is 1.72 kWac and consists of (8) modules and (8) micro-inverters. Project site is (2) duplexes on the same property both served by a single 400-amp service.Note: This is (1) of (2) duplexes. The other duplex is also having PV installed and can be found under 17041-20000-15066 and 17041-20000-15070	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58276	12041-10000-26613	3553 E BESWICK ST	90023	14	120A227   144	5191012031	(T)(Q)RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Apartment			11/06/2012 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.02223	-118.19931	NEW 33 UNIT APARTMENT WITH 6 TYPICAL UNITS.  (DEFERRED VARIANCE: CONTRACTOR WILL FILE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58277	15041-10000-10717	444 S FLOWER ST SUITE 120	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58278	14041-20000-02120	10130 N VALJEAN AVE	91343	12	204B137   637	2678002006	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.25485	-118.48701	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58279	17041-10000-33104	133 W AVENUE 45	90065	1	147A225    89	5467009001	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1851.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.09657	-118.20819	PC FOR INTERIOR ALTERATION OF ( E ) GROCERY STORESCOPE INCLUDES NEW PANEL CIRCUITS EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 970 SQ.FT. B# 17016-10000-22521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58280	11041-20000-19804	1121 N WATERLOO ST #A	90026	13	141A207   333	5402018***	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			09/16/2011 12:00:00 AM	10/20/2011 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.07916	-118.26668	Plan check new installation of roof mounted 2.365KW photovoltaic system for unit #A in condo building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58281	19041-20000-09109	856 S GRAMERCY DR	90005	4	132B193   801	5092024020	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			03/13/2019 12:00:00 AM	10/12/2022 12:00:00 AM		Issued	10/12/2022 12:00:00 AM	ADDRESS	34.05643	-118.31205	new apartment building 2000 amp service. plan check for power and energy.  (53) units total, 49 units typical, affordable housing, 5 story	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58282	19041-10000-27432	7701 N MASON AVE	91306	3	189B109  1097	2108024009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.21016	-118.57997	PV1. SYSTEM SIZE OF 4.69 KWDC/4.31 KWAC ROOF MOUNTED WITH (14) MODULES AND OPTIMIZERS, (1) 3.8 KW INTERVER (SE3800H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58283	10041-20000-25173	6109 N DE SOTO AVE	91367	3	177B105    43	2149005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM			PC Info Complete	12/17/2010 12:00:00 AM	ADDRESS	34.18151	-118.5908	Changes from previously approved plans 10041-20000-09578.  Changes include install some new lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58284	14041-20001-34260	16457 W KINGSBURY ST	91344	12	207B137   488	2679014020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM			PC Approved	12/21/2014 12:00:00 AM	ADDRESS	34.26391	-118.49105	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). Ungrounded system.36  255W pv modules across 4 strings (inv1: 9+9; inv2: 10+8).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58285	14041-20000-07830	5601 N DE SOTO AVE BASEMENT-to 5th fl	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.17126	-118.58861	T.I. to Kaiser Permanente building in Tele Communication room from Basement to 5th floor.  Install UPS and HVAC equipment.  Plan check for power only.Note: Lighting plans approved and permitted under 13041-20001-34916.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58286	13041-10001-32242	1340 35TH ST	0	15									Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM				Expedited RSES plan check per applicant request.(((PV1, Install 3.25 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3000A-US. 13 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58287	13041-10000-31565	9000 N SUNLAND BLVD	91352	7	195B173   151	2544026032	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	02/02/2024 12:00:00 AM	ADDRESS	34.23264	-118.36658	RENOVATION AND CHANGE OF USE FROM RETAIL TO NURSING SCHOOL FOR EXISTING  BUILDING.DEVELOPMENT OF 50 CAR PARKING LOT.  Lights more than 2 mounting heights away from the property line.PC TIME EXTENSIONS HAVE BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58288	17041-10001-21386	7866 W FAREHOLM DR	90046	4	147B177    94	5551004011	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.10298	-118.36114	EXPEDITE FEESPC FOR PV SYSTEM. TOTAL SIZE 11.5KW AC. USINCE AC TYPE SOLAR PANELS. TOTAL OF 32 MODULES. ALL ROOF MOUNTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58289	15041-10000-09055	1431 S SHERBOURNE DR 1-5	90035	5	129B169   178	4303018010	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			06/19/2015 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.05307	-118.37984	NEW TYPE V-A   3- STORY 5 UNITS APARTMENT OVER 1-STORY TYPE I-A PARKING GARAGE.NEW 600 AMP SERVICE.  PLAN CHERCK FOR POWER AND ENERGY.FIRE VARIANCE ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58290	14041-10002-14855	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.18088	-118.48309	UPDATE PLANS TO MATCH CURRENT FIELD CONDITIONS. INSTALLING 3000A SECTIONS AND CHANGES SIZES OF MAIN BREAKERS. CHANGES CLOUDED DELTA 1 ON PLANS. ALSO ADDED NOTES FOR DUMMY SECTIONS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58291	17041-20002-17587	18025 W PARTHENIA ST	91325	12	195B125   776	2768010016	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM			PC Approved	09/01/2017 12:00:00 AM	ADDRESS	34.2288	-118.52592	09/01/2017 Changes to an approved set of plans. PV interconnection has changed from a line-side tap to a load-side connection. Connection is being made onto a 400-amp split-bus panel. *****Previous Work Description*****PV1. ADDITION OF 8.4KW TO EXISTING SYSTEM. LINE SIDE TAP. TOTAL SYSTEM 15KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58292	15041-20000-19829	20800 W DEARBORN ST	91311	12	198B109   153	2748037018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.23712	-118.58631	add 4 panels and two transformers TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58293	13041-20000-32077	11950 W WILSHIRE BLVD	90025	11	129B145  1072	4263005043	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.04571	-118.4652	PC FOR T24 ENERGY ONLY. TOTAL AREA 2799 SQ FT. PERMIT ALREADY ISSUED UNDER APPLICATION # 13041-20000-27966))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58294	15041-20000-09666	830 W 34TH ST	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	PIN	34.02190161	-118.28374695	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOMS IN USC RAMO HALL OF MUSIC. 2ND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58295	12041-20000-29340	14117 W HUBBARD ST UNIT 3	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.29849	-118.44081	Plan check for power and energy. First time tenant. Unit 3. 1032sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58296	19041-10000-13249	955 N STONEHILL LANE	90049	11	138B141   121	4493022018	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.07652	-118.48494	Plan check for two new Tesla Powerwall betteries (13.5kWH) for a Battery backup system with existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58297	14041-20000-21842	12751 W MILLENNIUM A101	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	PC FOR NEW DISTRIBUTION EQUIPMENT FOR SHELL OUT A TENANT SPACE. PLAN CHECK FOR NEW 2013 BUILDING EFFICIENCY STANDARDS FOR POWER DISTRIBUTION. NEW 600A SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58298	14041-10001-16867	11816 N TURTLE SPRINGS LANE	91326	12	216B117   228	2701027009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.28664	-118.56293	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR SYSTEM. MICROINVERTED NON STANDARD PLAN. SYSTEM SIZE 8.25 KW DC. (33) TRINA SOLAR  250 MODULES(33) M215-60 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58299	14041-20000-17026	7230 N MEDICAL CENTER DR Unit 607	91307	12	183B097    18	2021014042	QCR-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.20143	-118.62922	TI to (E) medical office for new diagnostics center.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58300	19041-30000-14906	801 S FIGUEROA ST 19th Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Info Complete	04/23/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the 19th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 715 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58301	14041-20000-21428	12543 W MARTHA ST	91607	2	174B161   337	2341016031	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.1732	-118.40691	PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 3.8kW(1) Aurora UNI PVI-3.8-TL-OUTD-S-US-A transformerless inverter(13) Sun Power SPR-E20-327 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58302	19041-20000-50865	15418 W HAMNER DR	90077	5	156B145    86	4378015017	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.12552	-118.46293	Plan check for PV roof mounted system, PV system size: 7.56KW with 24 PV Modules and 1 inverter and 2 Energy storage system Tesla Power Wall 2.0. Energy Storage System size: 75KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58303	13041-20000-13694	3620 S VERMONT AVE RM 113-167	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.02213	-118.29133	PLAN CHECK FOR CONTROLS. T24 ENERGY ONLY. NO CHANGE IN FIXTURES, NO CHANGE IN LIGHTING POWER, PLAN CHECK FOR CHANGE IN CONTROLS ONLY. WORK DONE IN ROOMS 113,137, 138, 141, 159, 163, 165, 166, AND 167.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58304	17041-10001-37741	17218 W SEPTO ST	91325	12	201B133    68	2694016028	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.25109	-118.50856	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 4.20KWdc / 3.92KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER. (14)MODULES-SOLARWORLD  SW-300(14)OPTIMIZERS-ENPHASE S280--60-LL-2-USNOTE: SOME FEES ARE COVERED UNDER MASTER PERMIT PCIS#17041-90000-37741	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58305	17041-20000-06150	17621-17623 W VENTURA BLVD	91316	5	171B129   337	2257008040	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.16222	-118.51693	PLANCHECK FOR T24 ENERGY.  INSTALL ONE DEMISING WALL TO CREATE NEW RETAIL TENANT SPACE WITH NEW ACCESSIBLE RESTROOM. 1096 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58306	15041-10000-22981	814 S FRANCISCO ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.04835	-118.26288	TI TO AN EXISTING MEDICAL OFFICE.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS. NEWLY CONNECTED LOAD <= 400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.  SCOPE OF WORK TO BE PERFORMED IN THE FIRST FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58307	11041-10000-01421	1 S LMU DR # 2ND FL	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	TENANT IMPROVEMENTS  IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58308	15041-20000-08914	6256 N TOPANGA CANYON BLVD #2280C	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	Plan check for power and Title-24 (energy).  Total area = 6,798 sq. ft.T.I. to restaraunt.  First time tenant.  New 75 kVA and 45 kVA transformers feeding 4 new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58309	17041-10000-41792	900 W WILSHIRE BLVD 12th floor	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR OFICE TI IN A HIGH RISE (12TH FLOOR) BUILDING FOR T-24 ENERGY ONLY. SCOPE INCLUDES PANELS, EQUIPMENT, CIRCUITS AND LIGHTING. TOTAL AREA EFFECTED 5222 SQ.FTB#17016-20000-32031	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58310	16041-20000-15077	5971 W VENICE BLVD	90034	10	126B173   934	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.03865	-118.37272	PV2.  INSTALLATION OF SOLAR SYSTEM ON CANOPY GARAGE. SYSTEM SIZE: 220 KW DC.BUILDING PERMIT # 16014-20000-01949Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58311	19041-10000-50248	12036 W PICO BLVD	90064	11	123B149  1085	4259039053	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	05/23/2022 12:00:00 AM		Permit Finaled	01/31/2023 12:00:00 AM	ADDRESS	34.02934	-118.44987	Energy plan check for a retail T.I. Scope includes new lighting and equipment with a total lighting (in/outdoor) area of 5,863-SQ FT.Bld# 19016-10000-38988	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58312	19041-10000-08261	3203 N CANYON LAKE DR	90068	4	156B185    16	5577036013	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM			PC Info Complete	03/20/2019 12:00:00 AM	ADDRESS	34.12776	-118.32732	NEW 12.6KW ROOF MOUNTED PV SYSTEM WITH 40 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58313	15041-10000-23845	11550 N INDIAN HILLS ROAD	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.27998	-118.45874	Full plan check for a medical office located in the 3rd floor of a commercial building; Main scope includes new lighting, equipment, and receptacles; Total area is 2673-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58314	17041-10000-26270	1016 N ALVARADO ST	90026	13	139-5A207 154	5404003024	[Q]C2-2D	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.07681	-118.26375	TITLE 24 PLAN CHECK FOR TI (CHANGE OF USE FROM AUTO REPAIR GARAGE TO HEALTH CLUB(GYM) (2,472 SF) / RETAIL (1,379 SF) / AND OFFICE (3,516 SF). TOTAL AFFECTED AREA = 5903 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58315	15041-10000-10957	1900 S AVENUE OF THE STARS 520	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI TO AN EXISTING HIGH RISE BUILDING, ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2170.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58316	14041-20000-26979	6438 N ALDEA AVE	91406	6	180B133   450	2230022007	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.1879	-118.50777	PV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN. TOTAL OF 3 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58317	11041-10000-03105	145 S BARRINGTON AVE	90049	11	135B145   633	4401007017	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM			PC Approved	02/18/2011 12:00:00 AM	ADDRESS	34.06436	-118.4692	Ti, for an existing restuarant , plan check for title 24 and emergency lighting.REF. #11042-10000-03598	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58318	18041-10000-43500	7702 N TAMPA AVE	91335	3	189B117  1019	2104011004	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.21044	-118.55334	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58319	14041-10000-09963	707 W WILSHIRE BLVD	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Expired	07/28/2016 12:00:00 AM	ADDRESS	34.04893	-118.2572	Plan check for energy only for relocating bank vault.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58320	16041-10001-25972	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Closed	12/14/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	12/12/2016 Changes to an approved set of plans. Changes include label on panel schedule revised, reduced scope of title 24 from 21,000 sq ft to 7,996 sq ft and additional loads. Changes apply to ADD-007 only{{{{{PLAN CHECK FOR POWER AND TITLE-24BUILDING PERMIT #16016-10000-11862SCOPE OF WORK DENOTED BY DASHED AND SOLID LINES.  FACILITY IMPROVEMENT FOR TERMINAL 2 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUS OPERATION, AND OFFICE RENOVATION.  17 NEW PANELS TIED IN TO EXISTING POWER DISTRIBUTION SYSTEM WITH ASSOCIATED LIGHTING AND EQUIPMENT.}}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58321	19041-20000-32317	1000 W WILSHIRE BLVD #230	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.05085	-118.26078	T24 PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL BLDG STE 230. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1364 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58322	15041-10000-39717	1546-1552 N WESTERN AVE	90027	13	148-5A193 333	5544022052	[Q]R5-2	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.09961	-118.30907	FIRE DMAGED BUILDING. REPAIR. NEW ELECTRICAL SERVICE. THIS PROJECT SHOWS 400A MAX. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58323	15041-10000-17831	10961 W SAVONA ROAD	90077	5	147B145   136	4377034012	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.09766	-118.46226	INSTALL NEW 7.6 KW  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (28) MODULES: KYOCERA KU2606XPA(1) INVERTER: FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58324	15041-10000-16643	12499 W OSPREY LANE #3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	ADDRESS	33.97883	-118.41112	PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 3 SIZED 1.38KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-12499.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58325	17041-20001-36747	10144 W HOLLOW GLEN CIR	90077	5	156B153   152	4382025***	RE15-1-H-RPD-HCR	South Valley, West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.12253	-118.44232	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) with AC coupled battery backup system for SFD.PV system size: 13.2kW ungrounded [(2) 6.6kW]. (48) 325W pv modules. (2) 5kW Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58326	15041-20000-32534	12233 W OLYMPIC BLVD Suite 140-240	90025	11	123B149   494	4259019006	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	PIN	34.03260477	-118.45671268	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting only. Total outdoor lighting area = 10,148 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58327	17041-20000-00405	1800 N VINE ST	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM			PC Info Complete	01/05/2017 12:00:00 AM	ADDRESS	34.10393	-118.3265	addition of (2) UPS 4.8kva to an existing commercial office building non-high rise. adding em lighting with new circuits.  this application to include general lighting for bathrooms and garage/garage lobby only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58328	12041-10000-05330	5700 W WILSHIRE BLVD #100	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Approved	03/08/2012 12:00:00 AM	ADDRESS	34.06218	-118.35303	INTERIOR NON STRUCTURAL OFFICE (8660SF) REMODEL TO THE 1ST FLOOR OFFICE SUITE 100 AND NEW EXTERIOR STOREFRONT.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58329	18041-20001-05983	3470 S TROUSDALE PKWY	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	34.02202	-118.28393	Supplemental for change in lighting type and change in lights installed. Permitfees under master permit 18041-20000-05983.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58330	19041-10001-38078	14009 N BARNER AVE	91342	7	231B153    71	2582005010	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM			PC Approved	10/18/2019 12:00:00 AM	ADDRESS	34.32674	-118.43759	Changes to an approved set of plans for residential PV system. Changes include revising single line diagram to reflect as built and removing one pv module from the plans. Note: Plan check only. Permit paid under original application 19041-90000-38078	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58331	19041-20000-17863	3651 S TROUSDALE PKWY	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.01922	-118.28617	T24 ONLY PLAN CHECK FOR EXISTING LABORATORY ROOM. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 686 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58332	18041-20000-24433	10910 N SWEETWATER CT	91311	12	210B117   426	2708030004	(T)(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.26881	-118.56454	Plan check for PV roof mounted system, system size: 15.2kW with 44 modules and 2 inverters(7.6kW) connected to existing 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58333	19041-10000-23445	425 E 58TH ST	90011	9	108B205   988	5101005011	M1-1-CPIO	South Los Angeles	Southeast Los Angeles	Zapata-King		2294.10	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	12/03/2020 12:00:00 AM	ADDRESS	33.98994	-118.26645	consolidating two services into one 800A,240/120v, 3ph,4w in an existing warehouse. core and shell only. no connected load. complete PC will be required for the TI.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58334	18041-20000-30128	14600 W ISLA VISTA DR	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.2474	-118.45043	Plan check for PV roof mounted system, system size: 2.88kW AC with 9 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58335	18041-10000-01310	17331 W TRAMONTO DR Bldg # 2	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	04/06/2022 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 2 (CAMPUS STYLE)SCOPE INCLUDES 104 DEVICES AND 2 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSEB#16010-10001-00077BUILDING 2  (PLAN A1/ A1R)  8 UNITS AND 4 STORY  TYPE IIA  APARTMENT  BUILDING WITH  TYPE IB GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58336	19041-10000-44356	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.09822	-118.31812	FULL PLAN CHECK FOR POWER AND ENERGY UNDER PHASE TWO, SCOPE OF WORK IS A TI (FIRST TIME), SCOPE OF WORK INCLUDES VARIOUS NEW SUBPANELS CONNECTED TO AN ELECTRICAL SYSTEM THAT WAS APPROVED UNDER 16041-10K-43434 TOTAL AFFECTED AREA IS (75,009)SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58337	16041-20000-45765	1919 S WESTERN AVE	90018	10	126B193  1003	5073030050	[Q]C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			Reviewed by Supervisor	02/02/2017 12:00:00 AM	ADDRESS	34.03919	-118.30924	new 6story mix use 22 apartment building.  2000 amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58338	10041-10000-11249	11860 W WILSHIRE BLVD # 301	90025	11	129B145   914	4263007075	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.04692	-118.46366	NEW LUMINAIRES AND RECEPTACLES IN EXISTING DENTAL OFFICE ;PLAN CHK IS FOR TITLE 24    El. permit for panel, 20 circuits &low voltage	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58339	19041-20001-23919	16037 W ARMINTA ST	91406	6	189B141   148	2206007011	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM			PC Approved	09/20/2019 12:00:00 AM	ADDRESS	34.21399	-118.48285	9/20/19CHANGES TO APPROVED SET ADD NEW COMBINER BOX.<<<Plan check for a PV2 roof-mounted PV system. System size is 15.75 kWdc/14.06 kWac-CEC and consists of (1) 12 kWac rated inverter and (50) modules.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58340	18041-20000-03840	3650 N LANKERSHIM BLVD	90068	4	159B173    64	2380001007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.13588	-118.36657	Plan check for the addition of a PV1 roof-mounted PV system and a battery storage system to an existing PV system. System addition size is 3.1 kWac and consists of (11) modules, (11) micro-inverters, (1) load center, and (1) Tesla PowerWall.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58341	19041-10000-10904	2445 E 12TH ST BLDG D	90021	14	120A217    96	5168003013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.02277	-118.22852	Energy plan check for an office T.I located in the 1st and 2nd floor of a 2-story commercial building. Scope includes new lighting and equipment with a total area of 6595 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58342	10041-10000-24208	6828 N VAN NUYS BLVD	91405	6	183B149   704	2217009016	(Q)RAS4-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Public Safety Only			12/06/2010 12:00:00 AM	12/06/2010 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.19475	-118.44846	NEW FIRE WARNING SYSTEM FOR A 68-UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58343	15041-20002-33464	7080 W HOLLYWOOD BLVD 7TH FLR	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	ADDRESS	34.10134	-118.34445	[[2/25/16  CHANGES TO APPROVED T24 ENERGY. DELTA 2 REVISIONS. CHANGES ARE CLOUDED]]]]Revisions made to approved set to accommodate architectural layout changes and field changes to lighting fixture schedule.  (((T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES ON THE 7TH FLOOR. TOTAL AREA IS 12,672 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58344	11041-10000-19679	7083 W HOLLYWOOD BLVD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM			Not Ready to Issue	09/29/2011 12:00:00 AM	ADDRESS	34.10173	-118.34439	TITLE 24 AND EMERGENCY LIGHTING FOR A RETAIL STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58345	13041-10000-32357	11347 W SUNSHINE TER	91604	2	162B173   682	2378020011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.13926	-118.37703	PV1, Install 8.25 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 33 modules module Yingli YL250P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58346	17041-10002-06076	19500 W PLUMMER ST Suite E	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.2426	-118.55846	09-22-2017 Changes to permitted set of plan. Changes include remove lighting fixtures T10. Changes apply to delta 6 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58347	18041-10000-17782	1320 E 7TH ST #220	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.03598	-118.24041	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT AT EXISTING OFFICE SPACE. 9103 SQFT. SUITE 220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58348	13041-20001-25590	7640 N HASKELL AVE	91406	6	186B141    32	2206012029	(Q)CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.20957	-118.47474	((NO EXPEDITE. FEE GENERATION ONLY. ))PV2. COMMERCIAL ROOF MOUNTED SOLAR. USING 5 INVERTERS. TOTAL SYSTEM SIZE 100KW AC. USING 341 MODULES.  TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. MAX 7 STRINGS PER INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58349	18041-20000-00129	9400 N MASON AVE	91311	12	198B109    68	2748022048	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Closed	04/26/2018 12:00:00 AM	ADDRESS	34.2413	-118.57962	"PLANCHECK FOR T24 ENERGY. NEW STORAGE CANOPY. ""COMPLY WITH DEPARTMENT ORDER effective date04/12/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATEBUILDING PERMIT # 16010-20000-02965"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58350	17041-20001-11995	400 N OAKHURST DR	90210										Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.07549	-118.39071	expeditepv2install roof mounted pv system sized 46kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58351	14041-20000-22237	1111 W WILSHIRE BLVD 105	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.05259	-118.26348	Change of used from retail to restaurant.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58352	19041-10000-51756	7545 N SAN FERNANDO ROAD	91505	2	186B177   570	2466036010	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	05/07/2021 12:00:00 AM	ADDRESS	34.20906	-118.35474	TENANT IMPROVEMENT TO (E) OFFICE AND WAREHOUSE BUILDING WITH MEZAMINE LEVEL TO BUILD INDIVIDUAL OFFICES AND BUILD STORAGE AREAS.NEW CIRCUITS AND LIGHTING SYSTEMPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58353	13041-10000-25121	2451 N SOLAR DR	90046	4	153B177   313	5571032006	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.11567	-118.35465	PV1 7.8KWdc 240V XFRM negative ground. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: FRONIUS IG PLUS V 7.5-1UNI] [( 30) MOD: AU optronics PM250M01_260W} ]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58354	14041-20000-21312	4101 N VANALDEN AVE	91356	3	162B117    33	2180008011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.14403	-118.55637	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222. 19.8KW PV1 roof-mounted system including: (72) Solarworld Plus SW275 mono black, (2) Fronius IG Plus A 10.0 and 6.0 inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58355	13041-20000-11127	11290 W CHALON ROAD	90049	5	141B145    95	4369040003	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.08479	-118.46139	PV1 2 STORY SINGLE FAMILY DWELLING. 64 MODULES AND 3 INVERTERS. TOTAL SYSTEM SIZE: 18.52 KW. [INVERTER: (2) SUNPOWER 6000P-TL-1 & (1) SUNPOWER 5000P-TL-1] [SOLAR MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58356	18041-10000-15952	15045 W SUNSET BLVD	90272	11	126B129    80	4423028900	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.04493	-118.52257	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58357	15041-10000-03001	5879 S FIGUEROA ST	90003	9	105B201    87	6004035013	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	33.98748	-118.28293	Title 24 plan check only.  Total area = 685 sq. ft.T.I. to existing warehouse space and addition of storage area.  New 400 A service + switchgear.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58358	18041-10000-11394	10250 W SANTA MONICA BLVD #2395	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Interior remodel of  first tenant take out tea shop ""Red Straw"". Scope of work include new interior and exterior alterations."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58359	15041-20001-29120	13281 W VAUGHN ST	91340	7	213B157   260	2524021021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	34.28173	-118.42257	EXPEDITE PER APPLICANT REQUEST{{{{{PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.57 KW}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58360	19041-10000-51274	5329 N BLUEBELL AVE	91607	2	171B161   173	2346021024	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	12/09/2020 12:00:00 AM	ADDRESS	34.16751	-118.41064	[EPLAN] PLAN CHECK FOR NEW ESS(TESLA POWERWALL) CONNECTED TO EXISTING PV1 SYSTEM -	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58361	15041-10000-34144	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.15886	-118.50032	PC for energy T.I for a bank of america.  Addiition of some offices in open spaces. Scope includes new lighting and receptacles, on the altered private offices and open area. Total sq  ft  is 3274.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58362	14041-20001-24538	1455 N GORDON ST	90028	13	147A189    89	5545013002	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Info Complete	02/18/2015 12:00:00 AM	ADDRESS	34.09737	-118.32024	(2/18/2015) REVISIONS TO AN APPROVES SET OF PLANS.  CHANGES CLOUDED ON PLANS, NO DELTA INDICATION.   Commercial office TI in (E) 1 story commercial office building.  Plan check for energy under 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58363	16041-10000-31752	10458 W CANTARA ST	91352	2	192B177   943	2407009016	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Expired	03/31/2024 12:00:00 AM	ADDRESS	34.21889	-118.35924	New PV1, rooftop solar installation 12kW AC system with (2) central inverters, and 40 modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58364	13041-10000-23622	11009 N GLORIA AVE	91344	12	210B141   763	2667009019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.27023	-118.47931	PV1.  Install 8.82 kW roof-mounted solar array, interconnect with main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58365	17041-20003-01333	10244 N WOODLEY AVE	91343	12	204B141   390	2669007018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2017 12:00:00 AM			PC Approved	02/10/2017 12:00:00 AM	ADDRESS	34.25673	-118.48466	[2/10/17 CHANGES TO APPROVED SET. CHANGES ARE CLOUDED.  DELTA 1 CHANGES. ADDITION OF THE KWHR METER TO THE SINGLE LINE ]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58366	18041-10000-25600	450 W OLYMPIC BLVD #B & C	90015	14	127-5A209 199	5139009015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.04266	-118.26051	FIRST TIME TENANT, NEW KOREAN BBQ RESTAURANT IN UNIT's B&C IN EXISTING BUILDING.  4,675 S.F. FULL PLAN CHECK. BUILDING PERMIT: 18016-10000-08911	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58367	17041-10000-15450	528 W 74TH ST	90044	8	102B201  1255	6020024008	[Q]R3-1	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	33.97258	-118.28378	Installation of new roof monted solar PV array on existing single family dwelling.  AC module system with total system size = 6.9 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58368	11041-20000-02836	6001 N DE SOTO AVE	91367	3	177B105    72	2149005033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	02/14/2011 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.17944	-118.59076	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING  FOR RETAIL STORE TI. ALL WIRING EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58369	15041-20000-07797	11363 N ACALA AVE	91340	7	213B149   740	2613021046	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.27705	-118.44948	Plan check for a PV1 roof-mounted PV system. System size is 3.44 kWac and consists of (16) modules and (16) micro-inverters. Standard plan is not being used.Note: Contractor has a B license.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58370	19041-10000-26991	4814 W 1ST ST	90004	4	138B189  1002	5516008011	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.07291	-118.31619	[E-Plan] Changes To Approve Set: Changes include adding two additional disconnects.Master Plan: 19041-10000-20509	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58371	16041-10000-12995	419 S SPRING ST	90013	14	129A211    54	5149024027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Expired	06/04/2024 12:00:00 AM	ADDRESS	34.04843	-118.24885	Temporary Power to an (E) build. (E) Service is 4800 V, 3-phase, 3W.  Temp. power to be provided to (2) elevators, (1) Fire pump, (4)  panels on 1st, 4th, 8th, and 12th floors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58372	19041-20000-07211	601 S FIGUEROA ST ste 175&-250	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	ti to an existing commercial space in a high rise building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58373	18041-10000-35982	6606 N VARIEL AVE	91303	3	180B105    44	2148029009	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Apartment			09/20/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.19029	-118.59257	Plan check for a fire alarm system located in a (7) story apartment building. Scope includes (1) fire alarm panel, (20) power supplies and (971) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58374	14041-10002-08931	12806 W STANWOOD DR	90066	11	114B149    76	4247010015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.01205	-118.44934	CHANGES TO APPROVED: MOVED 4 MODULES TO ANOTHER PORTION OF ROOF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58375	19041-20000-23919	16037 W ARMINTA ST	91406	6	189B141   148	2206007011	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.21399	-118.48285	Plan check for a PV2 roof-mounted PV system. System size is 15.75 kWdc/14.06 kWac-CEC and consists of (1) 12 kWac rated inverter and (50) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58376	14041-10001-00191	4900 S BELOIT AVE	90230	11	111B165   574	4215027016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	33.99907	-118.4032	)))))))) PLAN CHECK ONLY FOR PV MICROINVERTER SYSTEM; ORIGINAL APPROVED PLANS WERE LOST. PLAN CHECK WILL BE CHARGED FOR 1 ADDITIONAL HOUR; THIS PLAN CHECK IS IN REFERENCE TO PC & PERMIT: 14041-20000-00191 ))))))))))))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.4 KW AC USING MICROINVERTERS STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58377	14041-10000-09760	3065 S MOUNTAIN VIEW AVE	90066	11	117B153   358	4248007005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Expired	05/16/2016 12:00:00 AM	ADDRESS	34.01866	-118.44263	PV1, Install 3.75 kw DC roof-mounted solar array on a two-story home, interconnect with main service panel.(1) Transformerless Inverter: SOLAREDGE SE3800A-US-ZB-U(15) CANADIAN SOLAR CS6P-250X	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58378	19041-10000-18235	3185 S MOTOR AVE	90064	5	123B161   752	4318033010	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Issued	05/24/2019 12:00:00 AM	ADDRESS	34.03163	-118.41137	$0.00 permit fee sue to senate bill 1222, and lb 1414(ePlan)  NEW 11.4 kW AC/ 15.2 KW DC SOLAR PHOTOVOLTAIC SYSTEM WITH OPTIMIZERS ON ROOF OF EXISTING HOME WITH 200A SERVICE.INSTALL (1) 11.4 KW INVERTER, (48) MODULES WITH (48) P370 OPTIMIZERS. *NOTE: DERATING MAIN BREAKER TO 175A SHALL BE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58379	17041-20000-23658	515 S FIGUEROA ST 6TH FLOOR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS AND BATHROOMS IN 6TH FLOOR OF HIGHRISE. 2039 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58380	14041-10000-15887	8018 W BEVERLY BLVD	90048	5	138B177   470	5511003023	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.07593	-118.3645	This is a 3 story with a basement. new fire alarm. 130 devices. and one panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58381	14041-20001-33172	13362 N GLADSTONE AVE	91342	7	225B153   237	2510021027	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM			PC Approved	12/24/2014 12:00:00 AM	ADDRESS	34.31467	-118.43299	EXPEDITE PER APPLICANT REQUEST[PV1PInstall a roof-mounted solar array on a SFD. Interconnect with 200A MSP (upgraded from 100A MSP).System size: 12kW (6+6). Ungrounded system.36 327W pv modules across 6 strings (inv1 - 6+6+6; inv2 - 7+6+5).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58382	16041-20001-01277	15511 W LA MAIDA ST	91403	5	168B141   277	2261036032	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	PIN	34.15875761	-118.47247489	EXPEDITE PER APPLICANT REQUEST[Install roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derating main to 175A.System size: 8.8kW (3.8kW + 5kW). (31) 327W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58383	17041-20002-32569	2408 E RIVERDALE AVE	90031	13	145-5A217 197	5445016015	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.09189	-118.23357	Revisions to approved set of plans.  Removal of energy storage system from the project scope.  $0 plan check fee per State Senate Bill SB 1222. (((PV1.  Install 5.7 kW roof mounted grid tied PV system.  (19) modules with (1) 5 kW rated string inverter.  13.5 kWh energy storage system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58384	15041-10000-22828	5422 W CARLIN ST #3	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/30/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	PV1, INSTALL 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON COMMERCIAL BUILDING.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58385	10041-10000-19648	1224 S BEVERWIL DR 1ST Flr	90035	5	132A167   219	4330024036	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	ADDRESS	34.0554	-118.39891	TI ON THE 1ST FLOOR & P1 LEVEL OF AN EXISTING HOTEL.  PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58386	16041-10001-30763	1220 N NORTH SPRING ST	90012	1	135A217    30	5409006030	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Info Complete	06/19/2017 12:00:00 AM	ADDRESS	34.06577	-118.23347	Plan check for power only.  Change of use from warehouse to restaurant and brewery.  Title 24 checked under master permit #16041-10000-30763.  Changes to approved set of plans. Changes include relocating panelboards in the electrical room, revising power floor plans, adding new branch circuits, and adding new panelboards. Note: Plan check only. Permit fees will be paid under master application 16041-10000-30763	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58387	14041-10000-23713	516 N LA JOLLA AVE	90048	5	141B173  1006	5528005040	R1-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.0807	-118.36785	PV1 Standard Plan, 7.395KW roof-mounted system including (29) Kyocera KD255 modules and one Power One Aurora PVI 6000OUTD inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58388	19041-10000-20915	927 N GALLOWAY ST	90272	11	129B129   860	4423019024	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.04629	-118.52101	{Zero permit fee due per AB-1414/ SB-1222}(ePlan) PV1 7.6 kW AC Roof Mounted Solar w 1 Inverter & 26 Modules @8.19KW & (2) New Energy Storage System @27KHW with (2) New 125A Load Center & (1) New 200A load center.*New 200A MSP shall be under separate permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58389	16041-10000-02076	22735 W CANTLAY ST	91307	12	186B097   980	2022003013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Expired	02/19/2018 12:00:00 AM	ADDRESS	34.20205	-118.62259	PV1, Install 3.445 kW DC roof-mounted solar array, interconnect with an existing pv system through a load center. (1) INVERTER:  ABB PVI-3.0-OUTD-S-US-Z-A.  (13) Modules: KYOCERA  KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58390	15041-20002-09662	1075 W CHILDS WAY	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM			PC Info Complete	02/04/2016 12:00:00 AM	ADDRESS	34.02304	-118.29105	02-04-2016 Changes to approved set of plans. Changes include remove lighing fixture F12 and add 5 F9A fixtures. Changes have been clouded{{{{{{{10/05/2015 Changes to an approved set of plans. All changes have been clouded. Changes include the addition of equipment, revised panel schedules, and revised lighting. Title 24 Compliance Forms have been updated.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.   TENANT IMPROVEMENT FOR MARKS TENNIS STADIUM IN USC. 9750 SQFT INDOOR AND 5500 SQFT OUTDOOR.}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58391	14041-10000-15162	1251 S LOS ANGELES ST	90015	14	124-5A209  90	5139027012	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.03627	-118.25909	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT LIGHT FIXTURES. TOTAL AREA 2888 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58392	19041-10000-30123	7221 N WOODMAN AVE	91405	2	183B157    14	2216034048	C1-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	PIN	34.20178024	-118.43200326	ENERGY PC FOR T.I. FOR (E) RALPHS. AREA OF SCOPE 1,324SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58393	10041-20000-25291	12930 W VENTURA BLVD #116	91604	5	165B161  1027	2385026024	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.02	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Closed	08/03/2020 12:00:00 AM	ADDRESS	34.14513	-118.41481	Plan check T24 energy (outdoor) for internally LED illuminated channel letter wall sign (29 s.f.). Building permit under #10048-20000-02418	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58394	18041-20000-11051	11051 W ART ST	91352	7	201B173   303	2538015012	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	PIN	34.24740552	-118.37229508	PV1.  Instal 5.95 kW DC roof mounted grid tied PV system.  (17) modules with power optimizers and 6 kW rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58395	16041-20000-17814	725 S FIGUEROA ST 27-29 flrs	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. FLOORS 27,28, AND 29. 11674 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58396	19041-10000-22517	1855 S WESTWOOD BLVD	90025	5	129B153   698	4323001009	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			06/12/2019 12:00:00 AM	06/09/2021 12:00:00 AM		Permit Finaled	02/17/2023 12:00:00 AM	ADDRESS	34.04867	-118.43619	Full pc for  apartment building with 3-basement garage levels. Service size is 2500A, 208/120V, 3Ph, 4W. Total area 39,854sf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58397	11041-10000-03353	3909 W OLYMPIC BLVD	90019	10	132B189  1243	5092016012	C2-1	Central	Wilshire	Greater Wilshire		2127.00	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.05371	-118.31989	PROPOSED TENANT IMPROVEMENT W/IN AN  EXISTING OFFICE, RESTAURANT AND GYM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58398	18041-10001-21048	1916 E 1ST ST	90033	14	129A221   284	5174016027	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Approved	09/27/2018 12:00:00 AM	ADDRESS	34.04613	-118.21695	DELTA 1 CHANGES TO APPROVED PLANS.<<<PC FOR ROOF MOUNTED PV ON COMMERCIAL BUILDING. SCOPE INCLUDES 38 MODULES WITH 38 MICRO INVETERS. TOTAL SYSTEM SIZE 9.0KWDC  /9.12KWAC>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58399	10041-20000-09500	19414 W VENTURA BLVD	91356	3	174B117   334	2163002059	C2-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	ADDRESS	34.17247	-118.55634	Plan check T-24 (general/emergency) lighting for existing classroom area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58400	11041-10000-24244	16023 W VANOWEN ST 1-10	91406	6	183B141   768	2224028029	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.01	Electrical	Electrical	Apartment			11/14/2011 12:00:00 AM	01/05/2012 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	ADDRESS	34.19409	-118.48217	Fire alarm system for New 10-unit condominiums with approx. 100 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58401	12041-20001-24240	18452 W HALSTED ST	91325	12	201B125   404	2764008001	(T)(Q)R3-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.24439	-118.53563	Change switch gear from square D to Siemens.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58402	17041-20000-07144	1540 S ROBERTSON BLVD	90035	5	129B169   540	4303002011	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	03/06/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.05108	-118.38408	new fire alarm system 40 devices and 1 facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58403	13041-10001-30568	600 W 7TH ST STE 160	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.04728	-118.25685	"CHANGES TO APPROVED: ACTUALLY A HIGHRISE. Emergency to be wired accordingly - no unit equipment allowed. Only 1 sheet (E-2)TITLE 24, PART 6 FOR ""JIMMY JOHN'S"" IN EXISTING RESTAURANT SPACE. TENANT IMPROVEMENT IS FOR LIGHTING IN 1515 SQ FT AREA. WORK IS DONE ON THE FIRST FLOOR OF A HIGH-RISE BUILDING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58404	19041-20000-16473	11666 W PENDLETON ST	91352	6	195B169   489	2631018047	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Issued	09/10/2019 12:00:00 AM	ADDRESS	34.22832	-118.38688	Plan check for power and energy  only service upgrade 1200A 277/480 Volt to the new  manufacturing building core and shell. Total area: 7672 sq ft. Note: There are 2 applications under 1 plan(19041-20000-16473 & 19041-20000-16467)B#18010-10000-01197	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58405	14041-20000-06351	15301 W VENTURA BLVD #550-#570	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.15411	-118.46654	T.I. to a high rise building on 5th floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 14041-90000-04084	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58406	16041-10000-10525	777 S FIGUEROA ST 37TH FLR.	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.04828	-118.26116	PC FOR T24 ONLY. T.I FOR  A COMMERCIAL OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING IN THE CORRIDOR/LOBBY. TOTAL AREA 2863 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58407	17041-20002-42726	7920 N MARQUAND AVE	91304	12	189B089   209	2020029049	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Issued	02/13/2018 12:00:00 AM	ADDRESS	34.21397	-118.64831	2/13/2018changes to an approved set of plans.  changes to include (2) tesla powerwalls.one tesla powerwall was charged under master application 17041-20000-42726(((pv1install roof mounted pv system sized 5.2kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58408	19041-20001-46474	24022 W SCHOENBORN ST	91304	12	192B089   149	2017037017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM			PC Approved	12/06/2019 12:00:00 AM	ADDRESS	34.22111	-118.64972	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY, CHANGE TO SITE PLAN AND EQUIPMENT ELEVATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58409	17041-10001-37318	6710 W VALMONT ST	91042	7	202-5A203   8	2570007016	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.25158	-118.27846	05-17-2018 Changes to an approved set of plans Changes include derated service and update main panel service rating.Fees $0.00 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58410	17041-10000-10081	313 W 8TH ST	90014	14	127-5A209  91	5144014026	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.0442	-118.25506	Plan check for new Fire Alarm system in commercial space. Total fire alarm devices: 25 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58411	12041-10000-08642	10250 W SANTA MONICA BLVD #195	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	"PLAN CHECK POWER AND ENERGY FOR TENANT IMPROVEMENT FOR NEW ""SEASONS 52"" RESTAURANT UNIT#195 AT CENTURY CITY MALL. MORE THAN 100 OCCUPANTS. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM FROM PLANS HAS BEEN FILED."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58412	14041-10001-30375	3152 S VERA AVE	90034	10	123B169  1031	4312007027	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	34.03155	-118.3865	Expedite Fee per applicante requestPV 1 roof monted system size: 6.54 KW DC with 20 modules Sun power SPR327NE-WHT-D and 1 inverter PowerOne PVI-6000-OUTD-US-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58413	11041-20000-14848	15643 W WYANDOTTE ST	91406	6	186B141   721	2206029016	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	06/10/2013 12:00:00 AM	ADDRESS	34.20311	-118.47409	Plan check power and energy for new 3-story 19 unit apartment bldg. 1000A service supplying bldg. Modification to seperate fire system has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58414	16041-10000-23184	5030 W PICO BLVD	90019	10	129B181  1009	5070017006	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.04766	-118.34728	PC FOR ENERGY ONLY. T.I. FOR AN ISRAEL GALLERY. TOTAL AFFECTED AREA IS 5200 SQ FT.SCOPE INCUDES NEW LIGHTS AND RECEPTACLES. B# 16016-10000-15166	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58415	14041-10001-19613	3708 N EAGLE ROCK BLVD	90065	1	154-5A217 154	5457029020	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.11757	-118.23347	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR HABITAT CAFE. FOOD PREPARATION. 1560 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58416	13041-10000-14444	6901 N TUJUNGA AVE	91605	2	183B173   184	2320002013	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.19626	-118.37921	NEW BUILDING WITH NEW 277/480 VOLT 3-PHASE 4-WIRE, 3000 AMP SERVICE. 66,469 SQUARE FEET OF INDOOR LIGHTING AND 3,036 SQ FT OF OUTDOOR LIGHTING. OFFICE, INDUSTRIAL, AND STORAGE USE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58417	15041-30001-38779	7900 S NARDIAN WAY	90045	11	099B157    74	4113022027	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	33.9666	-118.42039	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.44 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58418	17041-20000-22559	3758 S HARVARD BLVD	90018	8	117B193   457	5041033008	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			Reviewed by Supervisor	07/12/2017 12:00:00 AM	ADDRESS	34.01884	-118.30604	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.51 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58419	14041-20002-21783	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	34.21328	-118.45279	08/31/2017 Changes to an approved set of plans. All changes have been clouded. PV interconnection has changed from line-side to load-side.08-02-16 Changes to an approved set of plans. Changes include remove PV carport from scope of work, as build layout of modules, change inverters from (6) 100kW to (18) 20kW and down size PV  system to 360kW. *****************Previouse Work Description***********************************$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.PV2 COMMERCIAL ROOFTOP. PLAN CHECK FOR FOR ROOF MOUNTED PV IN 2 LOCATIONS. ONE ON EXISTING BUILDING AND ANOTHER ON NEW PARKING CANOPY. ALL FALLS UNDER SAME PV SYSTEM. TOTAL SYSTEM SIZE 600KW AC USING 6 CENTRAL INVERTERS. TOTAL 664KW DC. CONNECTION TO 480V 1000A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58420	18041-20000-36559	11670 W SAN VICENTE BLVD SUITE 'C'	90049	11	129B145    29	4265006009	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.05356	-118.46418	Plan check for Title 24 only in existing space T.I. Beaty Salon. Total area: 1450 sq ft. B#18016-20000-30038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58421	11041-10000-17920	888 W 6TH ST 9TH FL	90017	9	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	10/20/2011 12:00:00 AM	ADDRESS	34.05062	-118.25846	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58422	18041-20000-06716	1639 N SAN ONOFRE DR	90272	11	135B133   246	4425002030	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM			PC Approved	09/15/2020 12:00:00 AM	ADDRESS	34.06192	-118.50359	PLAN CHECK ONLY FOR A  NEW 600 AMP 240/120 3 PHASE 4W SERVICE, THAT FEEDS A 600A SWITCHBOARD WITH ALL ASSOCIATED HOME LOADS. NOTE ELECTRICAL PERMIT SHALL BE COVERED BY BUILDING COMBO PERMIT, 17014-30000-00868.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58423	17041-20001-41686	2300 W BEVERLY BLVD	90057	13	136-5A205 272	5154010034	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.06761	-118.27314	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 30 kWac and consists of (2) inverters, (90) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58424	18041-20000-42731	7647 N ST CLAIR AVE	91605	2	186B165    80	2307008006	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.20997	-118.39963	Plan check for PV roof mounted system, system size: 8.28 KW DC, 7.6KW AC with 23 modules and 1 inverter(7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58425	15041-10000-26538	633 W 5TH ST	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY. LOBBY ENTRY AREA, LEVEL 2. TOTAL  AREA 300SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58426	14041-20000-34219	19871 W NORDHOFF ST	91324	12	195B113   717	2782037***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.23203	-118.56649	Installation of (N) fire alarm system in a commercial medical office/surgery center.  53 new devices total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58427	18041-20000-17543	6400 N LAUREL CANYON BLVD Suite 640	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.18693	-118.3963	Plan check for Title 24 Energy only in existing space T.I. Office lighting and receptacle. Total area: 4364 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58428	13041-10000-18987	2666 W PICO BLVD	90006	1	129B197  1130	5075007002	[Q]C2-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	09/03/2013 12:00:00 AM	ADDRESS	34.04705	-118.29668	Installation of new fire alarm panel. horn/strobe pull section and smoke detector. 1 stories. Commercial. 20 devices and 1 panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58429	15041-10000-08084	200 WORLD WAY # 223	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	T24 ONLY. INSTALL ILUMINATED SIGNAGE NOT VISIBLE FROM ROW. TOTAL AREA 62.5 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58430	17041-20000-11949	19209 W VANOWEN ST	91335	3	183B117  1040	2129015009	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.19398	-118.55168	PV1.  Install 3.8 kW roof mounted grid tied PV system.  (12) modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58431	14041-10000-29542	1145 S GAYLEY AVE	90024	5	132B149   118	4363023033	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.05935	-118.44602	New fire alarm system for a retrofit of existing commercial building.  Addition of notification devices in common areas.  109 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58432	18041-10000-21268	12566 W ROSE AVE	90066	11	117B153  1130	4247023014	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.01336	-118.44443	PV1, ROOF MOUNTED SOLAR SYSTEM USING MICRO INVERTERS. TOTAL (10) MODULES AND (10) IQ6 MICROINVERTERS. TOTAL SYSTEM SIZE IS 2.4KWAC / 3KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58433	16041-10000-14891	2403 S VERMONT AVE	90007	8	123B197   589	5054026031	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.03438	-118.29178	Change of use of Retail space to a Restaurant. Hours of Operation will be from 7:00am to 11:00pm. Maximum 3 employees at any one time.  Connected load < 200A. PC for T-24 only. Total area: 1,225 sq.ft.B# 16016-10000-03957	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58434	18041-20000-48526	7561 W DEVISTA DR	90046	4	153B177   114	5569020028	RE11-1-HCR	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	01/19/2019 12:00:00 AM	ADDRESS	34.11816	-118.36421	Plan check for Energy Storage System installed into existing PV System, LG Chem Battery 9.8kWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58435	15041-10000-08970	2479 W WASHINGTON BLVD	90018	10	126B189   884	5073024027	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			Reviewed by Supervisor	04/07/2015 12:00:00 AM	ADDRESS	34.04007	-118.3172	SERVICE UPGRADE FOR EXISTING MIXED USE BUILDING. ALL LOADS ARE EXISTING PER APPLICANT. NEW SERVICE EQUIPMENT AND PANELBOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58436	16041-20000-18054	7230 N MEDICAL CENTER DR Ste 604	91307	12	183B097    18	2021014042	QCR-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.20143	-118.62922	TI to (E) medical office - addition of X-ray machine and associated loads.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58437	17041-10006-04779	6815 S VICTORIA AVE	90043	8	102B185   550	4006023004	MR1-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	33.97641	-118.33248	CHANGE OF ADDRESS FROM 6821 S VICTORIA AVE TO 6815 S VICTORIA AVE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58438	19041-20000-24853	2729 S MCCONNELL DR	90064	5	126B165   245	4308006007	R1V2-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Issued	06/27/2019 12:00:00 AM	ADDRESS	34.04366	-118.40285	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.52KW DC/10.272KW AC CEC. SCOPE OF WORK INCLUDES (32) SUNPOWER PV MODULES WITH INTEGRATED MICRO INVERTERS AND A 100A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58439	15041-10000-06700	7500 N VINELAND AVE	91352	2	186B173   507	2410001031	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.20664	-118.37007	New fire alam system for 12-units 4-stories apartment. Work includes (1) fire alarm panel, (1) annunciator, (1) power supply, and (75) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58440	12041-10001-18876	1875 E 22ND ST	90058	14	118-5A215 117	5167006013	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM			PC Approved	02/27/2013 12:00:00 AM	ADDRESS	34.01661	-118.23726	Revision to approved plans. Plan check for new 800A overhead service (Delta System), new branch circuits, and relocate two panels. Site located in methane buffer zone. No installation in hazardous area. Retrofit existing building power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58441	18041-10000-43331	985 S SEASIDE AVE	90731	15	015B205    18	7440032904	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			Reviewed by Supervisor	11/21/2018 12:00:00 AM	PIN	33.73479274	-118.26921687	TEMP POWER FOR CONSTRUCTION. NEW 3000 AMP 277/480V SERVICE & OTHER RELATED LOADS IN PORT OF LA.ELECTRICAL PLAN CHECK: 18041-10000-09089BUILDING PERMIT: #18010-10000-01108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58442	19041-20000-20173	2049 S CENTURY PARK EAST 38th Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is the 38th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area - 23,104 sq. ft.Note: Building application has been generated under 19016-10000-14504	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58443	13041-10000-24224	264 S WILTON PL	90004	4	135B189   171	5516016028	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.06919	-118.31388	][][]PLAN-CHECK ONLY ORIGINALLY DONE UNDER ADDRESS 268 S WILTON PL; PERMIT WILL BE PULLED ON SEPARATE PERMIT # . THIS PLAN CHECK IS FOR SOLAR INSTALLATION FOR ADDRESS   264 S WILTON PL. ][][]ROOF MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECT WITH MAIN PNL.SYSTEM SIZE 2.695KW IN A SINGLE-STORY HOUSE. TRANSFORMERLESS WITH POWER OPTIMIZERS.(11) MODULES: TRINA SOLAR #TSM-245PC05/PA05.18(1) INVERETER: SOLAREDGE #SE3000A-US(11)OP: SOLAREDGE OP250-LV	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58444	18041-10000-07051	147 W 24TH ST	90007	9	121-5A205 101	5126034021	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.02755	-118.26898	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 5700 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58445	12041-20000-19616	4649 N LOWELL AVE	91042	2	201B205   787	2571005038	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	PIN	34.24344252	-118.26641438	Plan check for PV system. sfd. 1.53kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58446	15041-10000-36563	7224 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM			Corrections Issued	10/30/2015 12:00:00 AM	ADDRESS	33.97406	-118.2913	New fire alarm system in existing grocery store.  Total system size = 44 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58447	14041-10000-15927	317-321 N PATTON ST	90026	1	135A209    39	5160003023	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			Corrections Issued	06/13/2014 12:00:00 AM	ADDRESS	34.06577	-118.25901	TITLE 24 PLAN CHECK ONLY - TOTAL AREA = 17,350 SQ FTGRADING DRAINAGE SITE LIGHTING ELEC PLAN EQUIPMENTS CCTV AND LANDSCAPING ASSOCIATED WITH PROPOSED POCKET PARK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58448	15041-10001-06077	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.06725	-118.41704	Revisions to approved set.  Additional radiant heater loads and additional areas in scope of work - admin. office, garden room, dining rooms, restrooms.  (((TI TO AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  REPLACING SWITCHBOARDS RECONNECTING TO EXISTING LOADS AND ADDING NEW LOADS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58449	15041-10001-36124	10539 W LE CONTE AVE	90024	5	135B153   165	4360020019	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM			PC Approved	11/09/2015 12:00:00 AM	ADDRESS	34.06731	-118.43454	EXPEDITED FEES PER APPLICANT'S REQUEST. (((PV1, ROOF MOUNTED SYSTEM TOTAL SIZE 8KW-AC. (24) MODULES AND (1) 8KW INVERTER. (24) SUNPOWER SPR-327NE-WHT-D(1) SMA-8000-US-A)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58450	18041-10001-25636	865 S FIGUEROA ST Lobby	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM			PC Info Complete	05/29/2019 12:00:00 AM	ADDRESS	34.04653	-118.26275	DELTA 3 CHANGES TO AN APPROVED T-24 PLAN. ADDITION OF ROOF EQUIPMENT, RECEPTACLES AND LOADS. MINOR CHANGES TO T-24 LIGHTING PLAN AND FORMS. TOTAL CONNECTED LOAD IS STILL LESS THAN 400A.  Original scope:((TENANT IMPROVEMENT TO LOBBY OF AN EXISTING OFFICE BUILDING.T-24 ENERGY ONLY. BULDING PERMIT # 18016-10000-21859))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58451	19041-20001-35367	5931 N RESEDA BLVD	91356	3	177B125   999	2156025023	R3-1	South Valley	Encino - Tarzana	Tarzana		1393.02	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM			Reviewed by Supervisor	09/19/2019 12:00:00 AM	ADDRESS	34.17832	-118.53621	Expedite per applicant requestPlan check for PV roof mounted system multi-family building, PV system size: 20.25KW with50 PV Modules and 2 inverters(7.6KW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58452	18041-20001-47153	11935 W LAUREL HILLS ROAD	91604	2	159B169    22	2377001019	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.13598	-118.39158	PV1.  Install 14.625 kW roof mounted grid tied PV system with 27 kWh energy storage system.  (45) modules with 5.2 and 7.6 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58453	15041-10000-37648	13630 W WILLARD ST	91402	6	189B157   247	2213019041	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.2175	-118.42943	PC FOR POWER AND ENERGY. TENANT IMPROVEMENT TO EXISTING DERMATOLOGY CLINIC SPACE.  TOTAL AREA  2029 SQ FT.B# 15016-10000-24326.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58454	13041-10000-10766	1950 E WASHINGTON BLVD	90058	14	118-5A215  29	5167005015	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	PIN	34.01879134	-118.23748008	PLAN CHECK FOR FEEDERS SUPPLYING TWO STATE APPROVED OFFICE MODULAR BUILDING (TRAILERS). SITE LOCATED IN METHANE ZONE. ELECTRICAL TI PLAN CHECK UNDER #12041-10000-24432.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58455	13041-20000-35328	21650 W OXNARD ST	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Closed	12/02/2014 12:00:00 AM	ADDRESS	34.17901	-118.60107	PC FOR POWER AND ENERGY. NEW LIGHING IN SMALL STORAGE CLOSET. POWER FOR EXISTING EQUIPMENT BEING REFED WITH NEW WIRING AND TRANSFORMERS. NEW WIRING WITH LOAD GREATER THAN 400A. NEW FEEDERS CHARGED AS PANEL BOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58456	14041-10001-29856	124 S CROFT AVE	90048	5	138B173   687	5511014007	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			01/12/2016 12:00:00 AM			PC Info Complete	01/20/2016 12:00:00 AM	ADDRESS	34.07387	-118.37406	1/20/16Changes to an approved set of plans, note changes on delta 2. Changes include adding a sensor ( permit fee will be added to original permit) to the methane control panel, revisions made to voltage drop calculation, and battery calculations. Also adding an electrical room on basement level park lot.Note: Original application under PCIS#14041-10000-29856(((Methange gas control system for a new 5 story apartment building.  13 devices + 1 control panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58457	12041-20001-01606	1413 E 20TH ST	90011	9	120A211   351	5129005011	[Q]CM-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	34.02162	-118.24853	T24 and emergency lighting plan check only for new one story warehouse building. Service is only 400 amperes.  Original submittal to building plan check is  100' X 160' 1 STORY TYPE III-B SPRINKLERED WAREHOUSE W/ 35' X 75' MEZZANINE AND ROOF TOP PARKING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58458	19041-20000-02879	6320 W 82ND ST	90045	11	099B165  1041	4108024038	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.96434	-118.39715	PLAN CHECK FOR NEW ROOFTOP PV 6.3 AC SYSTEM ON EXISTING SFD. (20) 315W PV MODULES WITH MICRO INVERTERS AND (1) 100A SOLAR LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58459	10041-10000-10459	189 S THE GROVE DR #F7A & F7B	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.07125	-118.35662	TI IN AN EXISTING COMMERCIAL SPACE IN SUITE #'S F7A & F7B.    PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS. PERMIT IS FOR NEW PANELS, NEW 30KVA TRANSFORMER AND NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58460	13041-10002-29911	960 E 3RD ST	90013	14	127-5A217  90	5163016011	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.04578	-118.23289	Changes to approved set of plans, the changes are  clouded and involve the change of the feeder to MSA 1 from from cupper to alum (900 mcm0 derating factor is used, also the changes include the relocatring of DWP transformer.  Permit is existing.  this is planc ehck only.Note:  Supplemntal 10001 is not used for this job>>>>>>>>>>>>>>>>Full plan check. Two story additon and interior renovation to an existing, two story professional school.  FA variance is filed,  Paint booth are listed by recognized testing laboratory. cra clearnce obtained under building permit 13014-10000-04395	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58461	13041-20000-09773	7144 N BALBOA BLVD	91406	6	183B133   171	2225018026	CR-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM	04/16/2013 12:00:00 AM		Permit Finaled	05/07/2013 12:00:00 AM	ADDRESS	34.20056	-118.50092	Fire alarm system for adult day care.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58462	14041-20000-31022	15300 W VALLEY VISTA BLVD	91403	4	166-5A145 216	2281005006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.14874	-118.46757	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.(34) SUNPOWER 327WATTS MODULES(2) SUNNYBOY 5000TL INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58463	16041-10001-10663	1007 W DON ST	90744	15	036B201    50	7414007014	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	33.79784	-118.27569	Supplemental PC for PV1, rooftop solar 3kW AC system. (14) ku2656zpa,  (1) PVI-3.0-OUTD* Although the modules are installed on address 1735 N. Wilmington, the Utility interacts with PV system for address 1007 W. Don St. ; Therefore, permit is under 1007 W. Don St.<<Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58464	16041-20001-45779	20922 W ROSCOE BLVD	91304	3	192B109   780	2109004024	P-1VL, [Q]C1-1VL, [Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.21974	-118.58937	[[3/29/17  CHANGES TO APPROVED SET. ADDITION OF 800AMP SWITCHBOARD AND INSPECTOR CORRECTIONS  ADDRESSED.]]]New service for a fish market. #20922.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58465	14041-10000-12670	3000 S ROBERTSON BLVD	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.03242	-118.39001	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING EVEREST COLLEGE. DENTAL TRAINING AREA, PLAN CHK IS FOR TITLE 24 ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58466	12041-20000-10971	5410 N SAN FERNANDO ROAD WEST	90039	4	165B201   258	5593005048	M2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.15046	-118.27445	Golden Road Brewery : Chloe's PubEnergy, egress lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58467	11041-10000-01146	4920 N BALBOA BLVD	91436	5	168B133    86	2259010001	C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Apartment			01/21/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	06/23/2011 12:00:00 AM	PIN	34.15959526	-118.50013686	out door parking lighting poles and energy title 24 . plan check power/ customer request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58468	18041-20000-22544	1317 S HOPE ST	90015	14	126A207   172	5134011031	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			06/18/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Issued	06/18/2018 12:00:00 AM	ADDRESS	34.03907	-118.26618	Plan check for new fire alarm system in 38 units apartment building. Total fire alarm devices: 113 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58469	18041-10000-19823	6315 W ARIZONA PL	90045	11	105B165   687	4110014015	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.97977	-118.39661	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58470	14041-20000-34312	13234 W ADDISON ST	91423	4	171B157  1071	2358012008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.16115	-118.42144	PV1. CENTRAL/STRING INVERTER STANDARD PLAN. SYSTEM SIZE 6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58471	16041-20000-12627	3551 S TROUSDALE PKWY SUITE 202	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.02066	-118.28531	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES IN USC BOVARD ADMINISTRATION. 1392 SQFT. SUITE 202	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58472	15041-10000-03231	909 N AVALON BLVD	90744	15	030B205    88	7423004017	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	33.78153	-118.26274	Plan check for fire alarm for clothing store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58473	13041-10001-36099	901 E 12TH ST	90021	14	123A211    87	5132014001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Issued	08/22/2017 12:00:00 AM	ADDRESS	34.03208	-118.24959	CHANGES TO APPORVED SET OF PLAN - SCOPE INCLUDES CHANGES IN LOAD CALCULATIONS, TITLE 24,  ALTERATIONS TO SINGLE LINE DIAGRAM (ADDITION AND RELOCATION OF PANELS, LOADS, AND CIRCUITS), AND RELOCATION OF PANELS(FAULT CURRENT CALCULATIONS CHANGED DUE TO RELOCATION OF PANELS).ORIGINAL PERMIT 13041-10000-36099Plan chek for power and energy for a shopping center with basement and 2 stories.,3rd floor and roof as parking. New 4000 amp service. 54 new panels. Total area for indoor lighting 77617 sq ft and outdoor lighting 3095 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58474	17041-10000-25351	6960 S CENTINELA AVE	90230	11	105B165   480	4220014060	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM			PC Info Complete	04/10/2018 12:00:00 AM	ADDRESS	33.9837	-118.39937	Plan check for PV roof monted system. System size: 42kW with 3 inverters(14kW) with 81 modules connected to existing 800A switch gear.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58475	18041-30000-20838	4749 W ELMWOOD AVE	90004	4	138B193    25	5522019003	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			06/05/2018 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/08/2021 12:00:00 AM	ADDRESS	34.07843	-118.31079	FULL PLAN CHECK FOR  A 4 STORY 13,250 SF 14-UNIT APARTMENT BLDG OVER A 6595 SF SUB-TERRANENA GARAGE. 1000A 120/240V, 3PH, 4W SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58476	12041-10000-04168	11100 W SANTA MONICA BLVD suite#725	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM			PC Approved	02/29/2012 12:00:00 AM	ADDRESS	34.04726	-118.44465	Ti in an existing office BLDG. Electrical plan check is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58477	15041-10001-20802	946 N ADELANTE AVE	90042	14	156A235    85	5716016002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM			PC Approved	07/23/2015 12:00:00 AM	ADDRESS	34.12302	-118.1713	EXPEDITED FEE FOR PV 15041-10000-20802(((PV1, ROOF MOUNTED SYSTEM TOTAL SIZE 6.54KW. 20 MODULES, 1 INVERTER AND 1 NEW 225 PANEL. (20) SUN POWER SPR-E20-327(1)SMA AMERICA SB6000TL )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58478	16041-10001-10748	7671-7673 W BEVERLY BLVD	90036	5	138B177   424	5527041004	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM			PC Approved	04/19/2017 12:00:00 AM	ADDRESS	34.07629	-118.35712	PC FOR APPROVED SET DUE TO INSPECTION CORRECTIONS. NO ADDITIONAL UNITS INSTALLED. PERMIT PULLED UNDER ORIGINAL APPLICATION.TI, PC for Energy only, total area 1,555 sq.ft.   Service upgrade under separate Permit# 15041-10000-43499. <<PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO  TAKE OUT DELI. 800A SERVICE UPGRADE under 15041-10000-43499>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58479	18041-10000-45625	4220 W MONT CLAIR ST	90018	10	123B185   840	5051006016	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	04/01/2022 12:00:00 AM	ADDRESS	34.03164	-118.33221	PLANCHECK FOR POWER AND ENERGY.  NEW CONSTRUCTION OF 5-STORY 100% AFFORDABLE HOUSING PROJECT . PROJECT CONSISTS OF (45) STUDIO UNITS AND (1) TWO BED ROOM MANAGERS UNIT.  SERVICE AT 1600A, 120/208 V, 3PH, 4WBUILDING PERMIT # 18010-10000-05791	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58480	15041-20000-00389	6220 N TOPANGA CANYON BLVD #1450	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	TI. Plan check for power and energy. First time tenant. REI outlet store. Topanga village. (Title 24 packet has been attached to the plans)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58481	17041-10000-09388	11239 W VENTURA BLVD #102	91604	2	162B173   294	2366035036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.14181	-118.37523	Plan check for Title 24 only in existing space T.I. Waffle Shop. Total area: 1755sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58482	19041-10000-46828	1367 N ST ANDREWS PL	90028	13	147A193   156	5544030052	R4-2	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	09/30/2021 12:00:00 AM	ADDRESS	34.09641	-118.31107	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58483	16041-20000-16845	3760 W WILSHIRE BLVD	90010	10	132B193    68	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	10/02/2016 12:00:00 AM	ADDRESS	34.06148	-118.30833	Plan check Title 24 only for existing restaurant T.I. . Total area: 3,540 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58484	12041-10000-30853	232 E 2ND ST	90012	14	129A213   468	5161024011	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.0495	-118.24258	Construct 5-story,  240-unit apartment with retail over garage, no disabled access.  Located in methane buffer zone. title 24 included, emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58485	19041-10000-42183	13300 S ESTRELLA AVE	90248	15	078B201    65	6132004029	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	33.91139	-118.28597	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58486	19041-20000-51512	3143 N DONA SARITA PL	91604	2	159B173   624	2380021014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.12868	-118.37819	Plan check for PV roof mounted system, PV system size: 16.38KW with 52 PV Modules and 2 inverters(7.6KW), Energy Storage system size: 54KWh with 4 Energy Storage Devices(Tesla Power Wall 2.0)Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58487	17041-20000-20755	16915 W ROSCOE BLVD	91325	12	192B133   234	2205001004	M2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.22139	-118.50174	New addition at front of (E) 1-story animal hospital.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58488	13041-20001-21971	7855 N HAYVENHURST AVE PV-2	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.21329	-118.49262	((changes to approved set of plans. pc for clouded changes only. running ac conduits underground.$0 plan check fee due to senate bill 1222 from 2012)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58489	15041-10000-09305	1828 S WESTERN AVE	90006	10	126B193   744	5074015051	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.04091	-118.30873	ADDING NEW SECTION TO AN EXISTING DISTRIBUTION BOARD IN LIVE/WORK UNITS.  ADDING NEW PANELS AND CIRCUITS.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58490	16041-20001-13046	15105 W MISSION HILLS ROAD	91345	7	213B145    24	2664022013	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Apartment			10/16/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.28165	-118.4621	Revisions to approved set of plans.  New emergency panel on rooftop and rerouting of emergency circuits, added outdoor walkway/parking site lighting, additional switch and outlet to standard assisted living unit. (((Plan check for power and energy. Project site is an existing commercial 3-story building (assisted-living apartments). Project scope is an addition of 44 units (3-stories) to the existing building. Note: Building application has been created under 16014-20000-01659)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58491	12041-20000-02605	10329 W PALMS BLVD	90034	5	120B161   400	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2699.07	Electrical	Electrical	Apartment			02/03/2012 12:00:00 AM			PC Approved	03/19/2012 12:00:00 AM	ADDRESS	34.02679	-118.40832	Delta 803 revisions to 09041-10000-24382( add 25HPgarage fan & 11 car chargers ) application not in effect	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58492	13041-10002-27681	170 N GLENDALE BLVD	90026	1	135A209   230	5160013013	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			PC Approved	12/10/2013 12:00:00 AM	ADDRESS	34.0639	-118.25974	][][CHANGES MADE TO APPROVED SET OF PLANS; REDUCING NUMBER OF MODULES FROM 24 TO 17 PER BUILDING REQUEST, AND DOWNSIZING INVERTER FROM 5kW TO 4 kW, TRANSFORMER TO TRANSFORMERLESS . NO ADDITIONAL CHANGES PER APPLICANT][][]PV2. ROOF MOUNTED 6.0KW DC PHOTOVOLTAIC SYSTEM ON STEEL CANOPIES ATTACHED TO COMMERCIAL BUILDINGS. (170 AND 180 GLENDALE AVE.) USING (24) LUMOS LSX 250 MODULESAND (1) SMA SUNNY BOY 5000US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58493	18041-20000-44962	218 S OCCIDENTAL BLVD	90057	13	136-5A201 162	5155013005	R4-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Apartment			11/27/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	06/26/2023 12:00:00 AM	ADDRESS	34.06857	-118.28128	Plan check for new fire alarm system for 47 units 5 levels. Total fire alarm devices: 165 and 1 FACP. B#15010-10000-02503	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58494	14041-10000-10816	1660 W BEVERLY BLVD	90026	13	135A207   240	5153012003	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Expired	09/07/2016 12:00:00 AM	ADDRESS	34.06404	-118.26497	Plan check for power and energy for T.I. of existing commercial space - New power and lighting systems.Change of use from post office to retail.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58495	16041-10001-22072	600 S HARVARD BLVD	90005	10	135B193   877	5503026007	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.06322	-118.30393	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE NEW OFFICE SPACE AND CHANGE TO SINGLE LINE. PC CHANGES DELTA 1 ON PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58496	13041-10000-21314	959 N SEWARD ST EAST BDLG	90038	4	144B185   969	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.08878	-118.33338	NEW BUILDING, CORE & SHELL OFFICE ,4 STORIES BUILDING, 9055 SF, PC IS FOR POWER AND ENERGY. 1 PLAN WILL BE SUBMITTED FOR 3 BUILDINGS; THIS IS BUILDING # 2 OF 3. DESIGNATED AS EAST-BUILDING ON PLANS. SWITCHBOARD SECTIONS NEEDS TO BE CHARGED, ELEVATION DIAGRAM IS MISSING. LOCATION IS IN METHANE ZONE .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58497	17041-10000-28695	14119 W RIVERSIDE DR	91423	4	168B153   430	2248024015	[Q]C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Issued	08/14/2017 12:00:00 AM	ADDRESS	33.9787	-118.31759	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING TO LED TYPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58498	19041-30000-21616	1450 S BARRINGTON AVE	90025	11	126B149    89	4263020011	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.03	Electrical	Electrical	Apartment			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.04504	-118.45689	Plan check for a fire alarm system for a 4-story, 20-unit apartment building. Fire alarm consists of (1) FACP and (98) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58499	10041-10002-18676	818-838 E 29TH ST	90011	9	118-5A207 325	5128015052	(T)(Q)R3-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM			PC Approved	12/20/2011 12:00:00 AM	ADDRESS	34.01762	-118.26081	Installation of two photovoltaic arrays of micro inverters, Enphase model 215, on the roofs of two carports.  the arrays supply existing distribution panels as shown on the plans.  System grounding and equipment grounding subject to inspectors's approval.  Existing permit 10041-10000-18676.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58500	18041-20000-18253	6600 N TOPANGA CANYON BLVD Space 49F	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	09/15/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,243 sq. ft.Note: Building application has been generated under 18016-20000-15554	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58501	15041-20000-37707	1477 W HILL DR	90041	14	165A227   164	5691024023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Issued	02/09/2016 12:00:00 AM	ADDRESS	34.14484	-118.19764	PV1. GROUNDED MOUNTED PV SYSTEM. SSYTEM SIZE 10.54 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58502	19041-20000-15612	3030 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	12/21/2021 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58503	13041-20000-14977	9703 W SOMBRA TER PV-1	91040	2	201B181    49	2545006019	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	34.25121	-118.342	PV-1. Transformerless inverter. 4.2kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58504	14041-20000-10454	6400 N OWENSMOUTH AVE A-C	91367	3	180B105    64	2146005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Expired	09/07/2016 12:00:00 AM	ADDRESS	34.18653	-118.6013	Install additional new 800A service for expansion in retail space.  All subpanels and branch circuits are not under this application.  Plan check for power only.Note: The existing 1600 A sevice to the building to be remained.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58505	15041-20001-39378	20790 W NORDHOFF ST Space 3	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	Plan check for power per inspection request. first time tenant. (((TI for (E) commercial space for new 1208 sq ft yogurt shop.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58506	16041-20000-24830	1237 S HOLT AVE 1-34	90035	5	132B173  1132	4332023027	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			07/14/2016 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.05466	-118.37863	Plan check power and energy for new 34 unit multi residential Building 5 story. Total area: 28,232 sq ft. Note: Fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58507	11041-10000-23507	1425 S SAN PEDRO ST	90015	14	123A209     2	5133029905	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.0319	-118.2549	New repair/garage for School buses.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58508	16041-20002-45450	341 S KENMORE AVE 1-63	90020	10	135B197   399	5502004015	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM			PC Approved	08/04/2017 12:00:00 AM	ADDRESS	34.06776	-118.29683	[[[[8/4/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ONLY. CHANGING MAIN BREAKER TO 250 ]]]]permit fee $0.00 by state senate bill no.1222PV2.  Install 36 kW AC roof mounted grid tied PV system.  (132) modules with (6) 6kW rated central inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58509	11041-10001-15949	3470 S MCCLINTOCK AVE CINEMATIC-ARTS	90089	9	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM			PC Approved	08/22/2012 12:00:00 AM	ADDRESS	34.0236	-118.28768	Modification to previously approved set to remove circuits, re-route furniture receptacles.  LOW VOLTAGE ITEMS ARE NOT A PART OF THIS PLAN CHECK.        <<<<NEW 3-STORY WITH BASEMENT ACADEMIC BUILDING.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58510	12041-10000-01286	400 W WORLD WAY Term. 4-Spc#4G	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	03/01/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. to an existing retail space at LAX, terminal 4, space 4G.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58511	15041-10000-01925	9531 N COZYCROFT AVE	91311	12	201B109   336	2748040028	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.24363	-118.58211	Title 24 plan check only.  Total area = 3059 sq. ft.Retrofit existing lights to LED with retrofit kits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58512	12041-20000-13621	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Closed	02/09/2024 12:00:00 AM	ADDRESS	34.04107	-118.25479	T.I. to existing high rise building on 1st floor mezzanin and 7th floor.  Add new panels, branch circuits, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58513	18041-10000-28635	11627 W CANTARA ST	91605	6	192B169   513	2311001014	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.21939	-118.38529	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58514	18041-20000-41937	22726 W INGOMAR ST	91304	12	189B097   951	2013032004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.2117	-118.6225	pv1install roof mountedf pv system sized 13KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58515	19041-10000-40113	137 N VIRGIL AVE	90004	13	138B197   628	5501007027	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.07469	-118.28704	PC FOR A NEW FIRE ALARM SYSTEM. SCOPE INCLUDE 117 FA DEVICES, AND 3 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58516	17041-10001-01273	11258 W NEBRASKA AVE 1-5	90025	11	126B153   247	4261020004	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM			Corrections Issued	02/02/2017 12:00:00 AM	ADDRESS	34.04413	-118.44561	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV,  INSTALLATION OF 5.04 KW DC /5.2 KW AC ROOF-MOUNTED SOLAR SYSTEM ON COMMERCIAL BUILDING. (16) MODULES: LG LG315NIC-Z4(1) INVERTER: DELTA SOILVIA  5.2 TL>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58517	17041-10000-12780	11101 S AVIATION BLVD	90045	10	132B197   748	5077024038	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	33.93392	-118.37959	PC for T24 only. PC for new outdoor sign lighting fixture and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58518	13041-20000-26009	16720 W RINALDI ST	91344	12	213B137   605	2682003007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.27902	-118.49636	PV1 TRANSFORMERLESS SYSTEM. 3 STRINGS FOR 1 INVERTER. 4.2KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58519	14041-20000-04728	20145 W VIA MEDICI pv1	91326	12	219B113    50	2701041015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Expired	03/29/2016 12:00:00 AM	ADDRESS	34.2948	-118.57244	pv1, roof mounted solar installation, interconnecting with (E) 300A main service PNL. downsizing main breaker for tie-in. ungrounded system, sized @ 5.5 kW DC, with (22) canadian solar #cs6p-250px, (22) OP300 power optimizers, (1) solaredge #SE5000a-us-zb-u	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58520	13041-20001-03955	4401 W SUNSET BLVD	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM			PC Approved	03/09/2015 12:00:00 AM	ADDRESS	34.09708	-118.28526	[[[[[02-24-15 Change to approved set of plan for power and energy. changes to outdoor lighting and changes to  load, delta 2 changes only]]]]]]]]PLAN CHECK OUTDOOR LIGHTING AND POWER IMPROVEMENTS FOR CHURCH OF SCIENTOLOGY EXISTING FILM STUDIO.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58521	18041-20000-35470	11415 N MONTALCINO WAY	91326	12	213B109   411	2701068022	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.27894	-118.58674	Plan check for batter back up system installed in to existing PV roof mounted. installed 3 Tesla PowerWalll 2.0 13.5kWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58522	19041-20000-23977	948 W ELYRIA DR	90065	1	148-5A219  77	5464013026	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.10204	-118.22142	PV1.  Install 4.095 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (13) modules with 3.8 kW rated string inverter and (2) 13.5 kWh energy storage units.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58523	14041-20002-10974	10331 N BEVIS AVE	91345	7	204B149   152	2648008028	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.25845	-118.4555	Change from the previously approved plans.  Change in reducing the number of junction boxes.Note: Permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****PV1 INSTALL ROOF MOUNTED PV SYSTEM WITH POWERBOX OPTIMIZERS, SYSTEM SIZED 7.5KW INTERCONNECTED WITH MAIN PANEL.  (2) SOLAREDGE TRANSFORMERLESS INVERTERS 3.8KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58524	10041-10000-04489	310 E OLYMPIC BLVD	90015	9	126A209   218	5145020037	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM	03/12/2010 12:00:00 AM		Permit Finaled	03/24/2010 12:00:00 AM	ADDRESS	34.03847	-118.25488	TI in an existing commercial area. Install outdoor lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58525	11041-10000-18007	1312 N EDGEMONT ST	90027	13	147B197  1046	5543019007	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	34.09576	-118.29596	TI  FOR  CONSTRUCTION OFFICE SPACES; CHANGE OF USE FROM AUTO REPAIR TO OFFICESPLAN CHK IS FOR TITLE 24 : PERMIT FEES ARE IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58526	15041-10000-11989	8725 S CROCKER ST	90003	9	096A205    86	6041017006	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	33.95835	-118.26823	TI TO AN EXISTING COMMERCIAL BUILDING.  RETROFIT EXISTING LIGHTING TO LED.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58527	18041-10000-09090	9301 N TAMPA AVE 172	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM			PC Approved	03/13/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVEMENT TO EXISTING RETAIL STORE; NEW LIGHTING IN SALES AREA, FITTING ROOM AND CORRIDORPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58528	12041-10000-28357	3680 W WILSHIRE BLVD 102	90010	10	132B193    65	5093006028	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM			Verifications in Progress	02/01/2013 12:00:00 AM	ADDRESS	34.06149	-118.30603	TI TO EXISTING STARBUCKS. NO EMERGENCY LIGHTING PER APPLICANT. occupant load is 36	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58529	18041-20000-18931	9200 N OAKDALE AVE 1st Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is the 1st floor of an existing high-rise building. Project scope is a tenant improvement. Total lighting area = 4,768 sq. ft.Note: Building application has been generated under 18016-20000-06557	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58530	16041-20000-29389	14200 W ARMINTA ST	91402	6	189B153   990	2212001017	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.21268	-118.44283	Plan check for power only. New food process line and associated equipment (Tortilla production line #3 - Mission Foods). TT-2000 is prefab equipment.  Class II, Div 2 in production area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58531	15041-20000-30008	105 S MARIPOSA AVE	90004	13	138B197   935	5518006026	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Apartment			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	05/02/2017 12:00:00 AM	ADDRESS	34.07254	-118.2996	Plan check for fire alarm system for condominium units. Total devices: 138.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58532	17041-30000-19820	10960 W WILSHIRE BLVD 16 & 17-Floor	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check for power and energy. Project site are the 16th and 17th floor of an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 45,202 sq. ft.Note: Building application has been generated under 17016-30000-15422	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58533	15041-20000-41053	6515 N MURIETTA AVE	91401	2	180B153   760	2238021008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.18904	-118.43902	PV1 roof mounted solar installation. 3.8kW AC system(17) SW275 Mono Black(1) SE3800A-USPOWER OPTIMIZER IS USEDStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58534	15041-10000-25597	1111 S FIGUEROA ST #104	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.04338	-118.26581	TI FOR A SPORTS BAR AT STAPLE CENTER. REPLACING LIGHTING FIXTURES WITH LEDS. ADDING TWO NEW PANELS. T-24,  PC FOR ENERGY ONY.  TOTAL AREA = 5538 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58535	10041-10000-17585	5670 W WILSHIRE BLVD 22nd Floor	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	10/06/2010 12:00:00 AM	ADDRESS	34.06222	-118.35208	Install a new Fire Alarm System in the server room of the 22nd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58536	19041-10000-18643	1212 S WESTMORELAND AVE	90006	1	129B197   825	5076018014	R4-1XL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			05/17/2019 12:00:00 AM			Reviewed by Supervisor	06/13/2019 12:00:00 AM	ADDRESS	34.04873	-118.28891	FULL PC FOR POWER AND ENERYG FOR A NEW 38 UNIT APARTMENT OVER BASEMENT GARAGE. 4 STORY OVER 1 BASEMENT LEVEL. SCOPE INCLUDES A NEW SERVICE. TOTAL AFFECTED AREA IS SQ. FT. b#17010-10000-00819	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58537	19041-10000-15239	2625 1/2 W BELLEVUE AVE	90026	13	139-5A205 272	5402009025	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.07595	-118.27338	PV2. NEW ROOFTOP SOLAR SYSTEM ON A 3 FAMILY DWELLING PROPERTY. SYSTEM CONSIST OF 14 MODULES (LG 335) AND 14 MICRO-INVERTERS (IQ7-60-2-US). SYSTEM SIZE IS 4.69KWdc AND 3.29KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58538	13041-20000-09398	11444 W OLYMPIC BLVD flr 9	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.03654	-118.44363	13041-20000-09398Plan check for energy and emergency lighting. Commercial high-rise. 9th Floor. Poms and Associates.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58539	13041-20000-29844	16167 W ROYAL OAK ROAD	91436	5	162B141   175	2286013008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM			Reviewed by Supervisor	11/05/2013 12:00:00 AM	ADDRESS	34.14143	-118.48363	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 27KW AC. ROOF MOUNTED. TOTAL OF 90 MODULES. USING TRANSFORMERLESS INVRETER NONSTANDARD PLAN. ZONING HAS BEEN CLEARED ON APPLICATION#: 13041-20000-22450refer to most recent set of plans.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58540	13041-20000-31905	14006 W RIVERSIDE DR #235, 236,-239,240	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC FOR POWER AND ENERGY. NEW H&M RETAIL. NEW LOAD GREATER THEN 400A, NEW 800A DISTRIBUTION. 22998 SQ FT USING TAILORED METHOD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58541	19041-10000-45591	5200 W LOS CABALLEROS WAY	90027	4	151-5A195  65	5588035005	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.11049	-118.30326	PV1, NEW ROOFTOP MOUNTED PV SYSTEM, SYSTEM SIZE IS 11.2 KWdc/7.6KWac. SCOPE OF WORK IS 34 MODULES (PANASONIC VBHN330SA17) WITH OPTIMZERS (P340) LEADING TO A CENTRAL INVERTER (SE7600H-US). MPU UNDER SEPRATE PERMIT.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58542	19041-20000-06573	925 S SCHUMACHER DR	90048	5	132B173   124	5088001014	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.06085	-118.37372	Plan check for a PV1 roof-mounted PV system. System size is 4.62 kWdc/4 kWac and consists of (1) inverter and (14) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58543	19041-10000-10111	6569 S VERMONT AVE	90044	8	102B197   168	6014012032	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	33.97934	-118.29198	PV2. New roof-top solar system at a commercial facility. System consists of 12 modules (sunPower SPR-X21-345), 12 optimizers (SE P400) and 1 central inverter (SE3800H-US). System size is 4.14KWdc and 3.8KWac. AC disconnect shall be fuesable rated for a minimmum of 32KAIC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58544	15041-10000-00900	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"PC FOR ENERGY T24 ONLY. REPLACE EXISTING FLOURESCENT LIGHTSIGN WITH LED LIGHTSIGNS. RETROFIT EXISTING FLUORESCENT LIGHT SIGN WITH THE NEW FACE PANEL. ADDED NEW LED SIGN CONNECT TO EXISTING POWER CIRCUIT.REFERENCE BUILDING PERMIT: 14048-10000-02686. PROPOSED 3'-9"" X 4'-10"" D/F ILLUM. POLE SIGN (9-0)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58545	14041-20001-08539	17111 W CEREDO PL	91344	12	219B133   685	2606005029	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.2928	-118.50602	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58546	10041-10000-18203	16281-16283 W SAN FERNANDO MISSION BLVD	91344	12	210B137   296	2681011036	C2-1VL, P-1VL, QC2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1111.00	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.2721	-118.48674	T.I. to existing building with medical exam rooms.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58547	10041-20003-00691	530 W 27TH ST 1-161	90007	9	121-5A203 113	5123018031	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	07/18/2011 12:00:00 AM	ADDRESS	34.0269	-118.27607	PLAN CHECK FOR REVISION TO APPROVED PLANS, DELTA F. PROVIDE 45KVA TRANSFORMER FOR 480V BOOSTER PUMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58548	18041-10000-46404	4812 E HUNTINGTON DR SOUTH	90032	14	142-5A233 166	5213016005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2014.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.08524	-118.17966	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58549	13041-10000-25090	2105 E 25TH ST	90058	14	117A215    40	5167007018	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.01492	-118.23441	TITLE 24 PLAN CHECK ONLY. 1 STORY. 1780 SQFT. WAREHOUSE. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58550	18041-10001-23554	355 S GRAND AVE 1900- 2010	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Approved	08/31/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	Change to approved set by adding (2) new circuits and (2) equipment. All changes under delta-8 only.(((PC FOR POWER AND ENERGY FOR OFFICE TI ON THE 19TH AND 20TH FLOOR. TOTAL CONNECTED LOAD >400ASCOPE INCLUDES NEW CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 23439  SQ.FTB# 17016-20000-36395)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58551	16041-10003-08351	524 E WASHINGTON BLVD	90015	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Approved	04/03/2017 12:00:00 AM	ADDRESS	34.0283	-118.25963	CHANGE TO APPROVED SET OF PLANS. CHANGE NOTED DELTA 2 ON PLANS. CHANGE TO INTERCONNECTION TO EXISTING SERVICE IS NOW LINE SIDE TAP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58552	17041-10000-19894	13058 W BLOOMFIELD ST	91604	2	165B161   480	2375013033	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	PIN	34.14900274	-118.41794951	PV SYSTEM FOR SFD. TOTAL SIZE 13.8KW AC. USING AC MODULES. TOTAL 40	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58553	12041-10000-15395	4166 W MELROSE AVE	90004	13	141B197   511	5539022033	[Q]C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			Corrections Issued	07/03/2012 12:00:00 AM	PIN	34.08342296	-118.29132504	Remodel and new addition of 557 sq. ft. to an existing McDonald's Restaurant.  Change to lighting, receptacles, loads.  PLAN CHECK ONLY for Energy with Emergency lighting.  Permit fees are under INPSECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58554	16041-10000-39736	777 S FIGUEROA ST #3750	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Issued	12/07/2016 12:00:00 AM	ADDRESS	34.04828	-118.26116	Plan check for Title 24 only in existing high-rise building for an office space (# 3750). Total area: 4,417 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58555	11041-20000-17751	127 S SAN VICENTE BLVD Bulletin-81	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 81 plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58556	18041-20001-31088	5900 W WILSHIRE BLVD #120	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.06237	-118.35809	Revisions to approved set.  Addition of (N) emergency egress lighting and lighting controls to open office area of tenant space. (((Plan check for Title 24 Energy only in existing high-rise building T.I. office space. Total area: 428 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58557	11041-10000-17921	7341 W WILLOUGHBY AVE	90046	5	144B181   763	5531020900	OS-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Expired	06/22/2018 12:00:00 AM	ADDRESS	34.08723	-118.35022	(4) NEW BASKETBALL LIGHTING STANDARDS AND (2)  RETROFIT HANDBALL LIGHTING STANDARDS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58558	12041-10000-26028	12751 W MILLENNIUM A-B	90094	11	102B161  1175	4211033020		West Los Angeles				2756.01	Electrical	Electrical	Commercial			12/12/2012 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Expired	09/23/2015 12:00:00 AM	ADDRESS	33.9761	-118.41651	New methane mitigation system for new mixed used building. Building A and Building B with common subterranean parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58559	15041-20000-12338	1894 N STANLEY AVE	90046	4	150B177   437	5551010043	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.10451	-118.35758	Plan check for power only.  New single family dwelling with 600A SERVICE. PERMIT ALREADY ISSUED UNDER BUILDING APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58560	18041-10000-21865	10846 N BONITA LANE	91345	7	207B149   114	2615022040	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.26736	-118.45516	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:  5.94 KW . 18 PV MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58561	13041-10000-31924	10901 W SANTA MONICA BLVD	90024	5	129B153   517	4324028019	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	PIN	34.04975121	-118.43848304	"BUILDINGTITLE 24 PART 6 ENERGY WORK FOR A 1155 SQ  COMMERCIAL BUILDING . SCOPE OF WORK IS FOR REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. ""COMPLY WITH DEPARTMENT ORDER effective date02/17/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58562	17041-10000-19102	2307 E 2ND ST	90033	14	127-5A223 237	5183009040	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.04286	-118.21146	PC FOR ROOF MOUNTED PV SYSTEM ON SFD.TOTAL SYSTEM SIZE 3.0KWAC12 MODULES  WITH OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58563	13041-10000-04209	5231 N ELLENWOOD PL	90041	14	163-5A221 216	5671021006	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	34.1417	-118.2183	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SIZE 5.5 KW. USING 17 PANELS. CENTRAL TRANSFORMERLESS INVERTER. PER SUPERVISOR REQUEST BACK ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58564	13041-10001-25634	453 S SPRING ST	90013	14	129A211    87	5149024001	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	10/02/2013 12:00:00 AM	ADDRESS	34.04778	-118.24948	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58565	13041-10000-22642	3856 S NORMANDIE AVE units 1-16	90037	8	117B197   760	5037009017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			10/02/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.01589	-118.30001	New 16 units apartment with 3 level.  First level is garage.  Install new 600A service, panels, and circuits.  Plan check for power and energy. Not methane.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58566	16041-20010-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			08/02/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	8/2/19changes to an approved set of plans.  changes to feeder size, length and voltage drop calculations.this is plan check only.changes are noted delta 17 only.7/2/19changes to an approved set of plans.  changes to feede tags, length and voltage drop calculations.this is plan check only.changes are noted delta 16 only.((((05/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 14. Changes have been made to indicated feeder sizes, lengths, and voltage drops.))))*****Previous Work Description*****SUPPLEMENTAL PLAN CHECK ONLYCHANGES TO AN APPROVED PLAN SET. CHANGES TO APARTMENT UNIT FEEDER SCHEDULE SIZES AND CALCS. CLOUDED DELTA 11 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58567	17041-10001-16088	20127 W SATICOY ST	91306	3	186B113   120	2114004045	(Q)C1.5-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.20848	-118.57207	11/13/17Changes to an approved set of plans, changes include the change of scope to T-24 for the restroom only. General lighting to be installed and PC seperately, existing panel. This is plan check only, permit is covered under the master permit# 17041-10000-16088____________________TI FOR BEAUTY SALON. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58568	10041-20000-19715	14624 W VICTORY BLVD	91411	6	180B149   897	2241003005	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.18644	-118.45185	T.I. to existing space.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58569	16041-20000-06263	11851 W STAGG ST	91605	6	189B169   686	2310023028	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.21221	-118.39173	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58570	19041-20000-09201	3520 S HUGHES AVE ev2	90034	5	120B165    50	4313010046	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			03/14/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.02864	-118.40272	addition of (24) EV chargers to an existing apartment building.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58571	13041-10000-22184	145-147 S LA BREA AVE BLDG. #E2	90036	5	138B181  1064	5513019008	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM			PC Approved	08/15/2013 12:00:00 AM	ADDRESS	34.07229	-118.34423	permit to be pulled at EPC counter only. PC for energy only. TI TO EXISTING BUILDING. 2 RESTROOMS. 2 branch circuits (1 for lighting and 1 for receptacles in building E2)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58572	19041-10000-22393	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	02/05/2021 12:00:00 AM	ADDRESS	34.09822	-118.31812	PC for commercial pv. system size is 10kw AC / 5.4KW DC, 15 module (LG NEON R model) with 15 optimizers (Solaredge P505), and  1 inverter (Solaredge SE10KUS) interconnecting through the load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58573	18041-10002-10626	2727 S KRIM DR	90064	5	126B165   597	4308015016	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.04119	-118.40004	SUPPLIMENTAL FOR THE TWO ENERGY STORAGE SYSTEMS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58574	17041-10000-33718	8500 W BEVERLY BLVD #725	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI IN AN (E) RETAIL SPACE IN A COVERED MALL. (SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN A RETAIL. TOTAL SQ. FT. 4493	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58575	16041-30000-18516	20620 W PESARO WAY	91326	12	210B109   477	2701051047	OS-1XL, [T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Expired	06/20/2018 12:00:00 AM	ADDRESS	34.27452	-118.58227	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (36) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58576	19041-10000-33268	2619 N FIGUEROA ST	90065	1	142-5A219 129	5446010023	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM	05/04/2020 12:00:00 AM		Issued	05/04/2020 12:00:00 AM	ADDRESS	34.08438	-118.22201	INTERIOR BUILD OUT OF A NEW RETAIL (HARBOR FRAIGHT) SPACE. AREA: 16,064 SQR FT. BUILDING PERMIT: 19016-10000-26514	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58577	12041-10000-13173	15639 W WOODFIELD PL	91403	5	162B141   125	2280003021	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2012 12:00:00 AM	06/07/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.14203	-118.47434	New 10.08kw rooftop mounted PV System for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58578	11041-20000-24190	10311 W MONTE MAR DR	90064	5	126B161    63	4308001013	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	12/21/2011 12:00:00 AM	ADDRESS	34.04219	-118.40767	PLAN CHECK 6.07KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58579	14041-10000-17059	1300 N SEPULVEDA BLVD	90049	5	144B141    26	4368001015	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.08696	-118.47442	NEW SINGLE STORY BUILDING FOR WORSHIP ON THE LEO BAECK TEMPLE SITE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58580	14041-20000-13191	4441 E ALUMNI AVE	90041	14	157-5A221 232	5474008019	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Apartment			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.12475	-118.21896	INSTALL NEW  FIRE MONITORING SYSTEM TO AN EXISTING THREE UNIT APARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58581	17041-20000-32846	11755 W WILSHIRE BLVD 14th Floor	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for Title 24 only. Project site are the corridors and elevator lobby areas of the 14th floor of a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,056 sq. ft.Note: Building application has been generated under 17016-10000-19237	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58582	17041-10000-25569	12255 W SKY LANE	90049	11	141B137    74	4493024022	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2017 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.08252	-118.48576	2-STORY SFD W/ATT. GARAGE & 1-LEVEL BASEMENT. SERVICE SIZE 120/240V, 1PH, 800AMP. B#15010-20000-00222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58583	17041-10000-10618	21733 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.16855	-118.60188	RESTAURANT TI. BAR RENOVATION. PC FOR POWER AND ENERGY. A OCCUPANCY GREATER THAN 100	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58584	18041-10000-30422	970 W 190TH ST STE 200	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	33.85812	-118.29302	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1539 SQ. FT. B#18016-10000-21702	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58585	18041-20002-04239	17259 W DEVONSHIRE ST	91325	12	204B133   166	2695015001	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM			PC Approved	03/08/2018 12:00:00 AM	ADDRESS	34.25773	-118.51007	3/8/2018changes to an approved set of plans.  changes to relocate existing equipment.  plan check only.    (((PV1.  Install roof-mounted PV system sized 15.2kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58586	15041-10000-42057	1135 E 33RD ST	90011	9	117A209   276	5114025022	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.01373	-118.25564	PV1, INSTALL2.385KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (9) MODULES: KYOCERA KU2656ZPA(1) INVERTER: SOLAREDGE SE3000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58587	13041-10000-35777	13038 W SAN VICENTE BLVD #B	90049	11	129B137   498	4264001004	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			Reviewed by Supervisor	03/06/2014 12:00:00 AM	ADDRESS	34.04835	-118.49101	Plan check for power and energy. First time tenant. Retail store in the mall. Tailored method.Total area 5133 sq ft.Suit # B. Store name:  Helmut Lang	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58588	12041-20000-10232	145 S FAIRFAX AVE	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	PIN	34.07292853	-118.36175524	2nd, 3rd, 4th floors bathrooms remodelEnergy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58589	19041-10000-06191	12225 W VENTURA BLVD	91604	2	162B165  1096	2367017900	(T)(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.1441	-118.39964	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58590	15041-20002-39125	18133 W VENTURA BLVD #1	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	[[[ 3/1/17 CHANGES TO APPROVED SET. DELTA 3 CHANGES. INSTALLATION OF DISCONNECTS FOR MEDICAL EQUIPMENT. REMOVING INSTAHOT WATER HEATERS AND PANELBOARD]]]]T.I. at (E)portion of medical office on 1st floor. PC for Power and Energy per art. 517.   Total area: 9,778 sq.ft . suite # 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58591	13041-20000-03719	1724 N HIGHLAND AVE 1-270	90028	13	148-5A185  63	5547011031	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Info Complete	03/04/2013 12:00:00 AM	ADDRESS	34.10238	-118.3385	FIRST TIME TENANT NEED COMPLETE PLAN CHECK ENERGY WAS APPROVED UNDER 130412000000622.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58592	17041-10000-34977	8936 N COMANCHE AVE	91311	12	195B113    41	2781035017	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Issued	09/29/2017 12:00:00 AM	ADDRESS	34.23369	-118.57215	REPLACE HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58593	17041-20001-13254	15157 W ROSCOE BLVD	91402	6	192B145   371	2654024013	(Q)RAS4-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	34.22161	-118.46296	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted array on commercial building.Interconnect with a 400A MSP. 23.4kW ungrounded system [9+14.4]. (89) 275W pv modules.Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58594	11041-10000-20639	1741-1753 S PENMAR AVE BLDG 33	90291	11	111B149   424	4243001046	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.00204	-118.45698	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58595	17041-10000-04994	403 E 5TH ST	90013	14	127-5A213 116	5148011014	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Apartment			02/15/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.04466	-118.24477	INSTALLATION OF A NEW FIRE ALARM SYSTEM FOR  AN EXISTING 4 STORY  72-UNIT APARTMENT BUILDING.214 FA DEVICES, ONE FA PANEL,  4 FA CONTROL PANEL AND ONE ANNONCIATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58596	14041-10000-16822	612 S FLOWER ST #104	90017	14	129A209   264	5144005124	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.0497	-118.25759	PLAN CHECK ONLY. permit pulled under 14041-10000-11886. plan check for energy only. BLDG#14016 -20-02717: CHANGE OF USE FROM RETAIL TO TAKE OUT (BAKERY) NO CHANGE IN PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58597	19041-10000-27064	9225 N DORRINGTON PL	91331	6	198B153   864	2642029013	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Issued	07/16/2019 12:00:00 AM	ADDRESS	34.23688	-118.43692	Plan check for 11.4kw AC / 11.8 KW DC roofmounted system with (1) inverter, (40) modules and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58598	16041-20000-33597	8615 W SKYLINE DR	90046	4	153B169   359	5564009021	RE15-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.1156	-118.3848	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58599	19041-10000-44282	1214 W 254TH ST	90710	15	036B197   661	7413005035	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			Verifications in Progress	02/10/2020 12:00:00 AM	ADDRESS	33.79367	-118.29798	INSTALLING NEW 1,200 AMP SERVICE, PANELS & LOADS IN A MANUFACTURING BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58600	18041-10001-01961	11401 N PORTER RANCH DR Rec. Build	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.2779	-118.57107	PLAN CHECK ONLY. DELTA 1 CHANGES ONLY TO AN APPROVED SET. REDUCTION OF THE OUTDOOR LIGHTING. Original scope:((PC FOR POWER AND ENERGY FOR A NEW RECREATIONAL USE BUILDING FOR ADJACENT RESIDENTIAL COMMUNITY. PART OF A CAMPUS STYLE RESIDINTIAL COMMUNITY. 1 STORY 35160 S.F BUILDING #11 OF 11))B# 17010-10000-04955	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58601	18041-10000-34955	523 W 6TH ST #707	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	Energy plan check for an office TI located in the 7th floor of a high rise building . Scope includes new lighting and equipment with a total area of  1983-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58602	17041-10001-32581	20750 W VENTURA BLVD #140	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.16638	-118.58506	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 2685 SQ. FT. B#17016-10000-21379NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-32581	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58603	19041-20001-20041	2719 S MCCONNELL DR	90064	5	126B165   212	4308006004	R1V2-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.04395	-118.40318	07/12/2019 Changes to an approved set of plans. System size has remained the same. Changes have been made to reflect field installation.*****Original Work Description*****PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING ADU. SYSTEM SIZE IS 5.76KW DC/5.04KW AC. SCOPE OF WORK INCLUDES (16) SUNPOWER SPR-X22-360-E PV MODULES WITH INTEGRATED MICRO INVERTERS, AND A NEW 100A SOLAR LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58604	19041-10000-50020	4220 W 3RD ST	90020	10	135B193   221	5503005022	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.06883	-118.30609	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58605	14041-10000-17221	7251 N DEERING AVE	91303	3	186B105   899	2111030017	PF-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.20242	-118.59674	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 4272 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58606	13041-10000-14107	13161 W MINDANAO WAY D6	90292	11	105B153    86	4212004004	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	33.98499	-118.43772	T.I. to existing building, suite #D6  (Men's Wearhouse).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58607	15041-30000-39702	4641 N CARITINA DR	91356	3	168B117   474	2178015005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.15457	-118.55667	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 8.2 kWac.  Two inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58608	17041-30000-19362	5925 W BARTON AVE	90038	13	144B189   904	5534025018	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Apartment			06/08/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.08813	-118.3232	Plan check for power and energy. Project site is a new 2-story, 5-unit apartment building with 1 level of basement garage. Work includes a new 400-amp service and a total lighting area of 3,775 sq. ft.Building permit: 15010-10000-03211	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58609	15041-20000-13520	6612 N ENSIGN AVE	91606	2	180B173   447	2319019014	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.19073	-118.37163	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, and (20) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58610	13041-10000-10507	735 S FIGUEROA ST Suite 113	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			PC Approved	04/23/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	T24 FOR EXISTING RETAIL SPACE (PAZZO GELATO). TENANT SPACE 113. 326 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58611	18041-10001-39776	21019 W ELKWOOD ST	91304	3	189B105   388	2109015024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	03/27/2019 12:00:00 AM	ADDRESS	34.21286	-118.5915	New roof-mounted 4.96KW solar PV system with 16 PV Panels on a single family home.Plan Check Only. Permit Number: 18041-90000-39776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58612	13041-10002-34500	4611 S ROMA CT	90292	11	102A149    56	4295004064	[Q]RD1.5-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	33.97167	-118.4583	CHANGES TO APPROVED SET. CHANGING FROM 10 MODULES TO 12 MODULES ONLY.PV1, Install a 2.65 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[ SUNIVA # OPT265-60-4-1B)] for 2-story house. With power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58613	19041-10000-32028	110 E 9TH ST 3rd floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Energy plan check for a partial office T.I located on the 3rd floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 13,481-SQ FT Note: Using Exisitng Circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58614	19041-10000-33906	1814 W JEFFERSON BLVD	90018	8	120B193   704	5041005002	[Q]C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Info Complete	08/28/2019 12:00:00 AM	ADDRESS	34.02543	-118.30934	"T-24 plan check for a TI to existing restrooms in a banquet hall. scope includes new lighting, receptacles, equipment and controls. total new connected load is less than 400A. Total affected area is 718 sq.ft (Building Permit #18016-10000-27839)""COMPLY WITH DEPARTMENT ORDER effective date11/01/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58615	18041-10000-07956	19315 W SATICOY ST	91335	3	186B117  1034	2116014019	QC2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Issued	04/03/2018 12:00:00 AM	ADDRESS	34.20851	-118.55454	"Plan check for T-24 only, ""Energy Reduction Project"" for Chase Bank. Replace indoor and outdoor luminaires to LED fixtures using existing circuits. Total affected area is SQ. FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58616	17041-10000-02816	8229 N WOODMAN AVE	91402	6	192B153   835	2213016021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.22031	-118.43267	"Plan check for Title 24 only in existing space T.I  to ""Little Caesar's"" Total area: 1694 sq ft. Load is less than  400A. B#17016-10000-01899Note: Some permit are paid under PCIS#18041-90000-06771"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58617	11041-10000-15693	633 W 5TH ST 17TH FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM			PC Approved	07/26/2011 12:00:00 AM	ADDRESS	34.05099	-118.25468	REMODEL OFFICE SPACE AT THE CONCOURSE AND PARKING LEVELPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58618	12041-10001-06543	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM			PC Approved	04/04/2012 12:00:00 AM	ADDRESS	33.94571	-118.38747	One for one panel repair replacement for a fire alarm system.  Supplemental application for PLAN CHECK ONLY, permit is under main application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58619	17041-10000-24186	5128 W MARATHON ST	90038	13	141B193   389	5535017014	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	02/09/2022 12:00:00 AM		Issued	02/09/2022 12:00:00 AM	ADDRESS	34.08479	-118.30985	PC for power and energy for apartment building renovation project with 43 units. Scope includes (1) new 120/208V 1000 A service, (2) distribution panel, (43) sub panels and other large equipment with a total T24 lighting area of 4,256 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58620	17041-10000-19437	2312 E DAMON ST	90021	14	121-5A217  77	5166009012	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	34.02859	-118.23183	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58621	18041-10000-06415	6600 N TOPANGA CANYON BLVD #2102	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC for T24 only for retail TI. Installing new panel, 45kVA XFRM, lights, receptacles,  and equipment. Total 3864sqft. B# 8016-10000-053. B# 18016-10000-053	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58622	18041-20000-38136	8326 W BLACKBURN AVE	90048	5	138B173  1015	5511034031	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			10/05/2018 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	05/11/2023 12:00:00 AM	ADDRESS	34.07168	-118.37111	1200A 240/120V 3ph-4w service, distribution, power, and lighting for new building.  Associated building permit under 15010-10000-04219.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58623	15041-10002-27586	22526 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	33.8213	-118.30137	CHANGE TO APROVED SET OF PLANS. ADD PERFORMANCE METER AND FUSED DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58624	14041-20000-35485	3050 S LA BREA AVE	90016	10	120B177   725	5049034037	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM			Corrections Issued	12/23/2014 12:00:00 AM	ADDRESS	34.02571	-118.35454	OUTDOOR LIGHTING. PC FOR T24 ENERGY ONLY. NEW SIGNS AS WELL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58625	16041-10003-11963	10250 W SANTA MONICA BLVD 195-Javiers	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Info Complete	05/11/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set noted under Delta-17:(1) Add 2 circuits for gas patio exhaust(2) revise power floor plan to show the new ckts(3) revise load schedule for panel IG to show the new ckts	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58626	19041-10000-45628	3888 S CRENSHAW BLVD	90008	10	117B185   941	5033003002	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.01498	-118.33473	TI IN AN EXISTING RESTAURANT / SPORTS BAR. INSTALLING NEW PANELS, CIRCUITS AND LIGHTS.  EXISTING SERVICE. ADDED LOAD IS BELOW 400AMP. TITLE 24 ENERGY ONLY. +AFFETED AREA: ~5700 SFT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58627	12041-20001-00571	11928 W VENTURA BLVD	91604	2	162B169   193	2369016009	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM			PC Approved	02/24/2012 12:00:00 AM	ADDRESS	34.14297	-118.39179	energy plan check pizza crust existing service revision to approved plans as built drwaings	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58628	16041-10001-15463	3650 W MARTIN LUTHER KING, JR BLVD SUITE 187	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	08/08/16Changes to an approved set. All changes are clouded under delta A, D, & E. Changes include replacing/relocating lighting fixtures.Note: Original application is under PCIS#16041-10000-15463(((((PC FOR ENERGY ONLY. T.I FOR TIME WARNER CABLE. TRANSFER FROM RETAIL TO TIME WARNER CABLE. TOTAL AREA 3965 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58629	13041-10001-33005	12100 N SALEM DR	91344	12	216B133   184	2606011028	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.29019	-118.50819	Expedited RSES plan check per applicant request.[][[][]PV1, Install 8 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(2)Transformerless inverter(s): SolarEdge SE3800A-US. (32) modules: Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58630	19041-20000-03002	6100 W CENTER DR 10th Flr	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	33.97733	-118.3922	Plan check for Title 24 only in existing space 10th floor Lobby, restroom and corridor Tenant Improvement. Total area: 1756 sq ft. B#19016-30000-00836	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58631	17041-20000-40584	21841 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.16859	-118.60329	CHANGE OF USE FROM RESTAURANT TO GYM. 3895 SQFT. PLANCHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58632	14041-20000-11222	16000 W VENTURA BLVD SUITE 400	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.15584	-118.48164	TI - ENERGY PLAN CHECKExisting high rise building, single story office remodel. All lights are new. All circuits are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58633	14041-20000-05461	6300 N CANOGA AVE #1200	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM			PC Info Complete	04/01/2014 12:00:00 AM	ADDRESS	34.18492	-118.59722	T.I. for an existing high rise building on entire 12th floor.  New added load less than 400A.Note: Initial submittal as full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58634	15041-10000-42297	5422 W CARLIN ST #1	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Apartment			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.03039	-118.3617	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.(11) KYOCERA 265 MODULES(1) ABB PVI 3000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58635	17041-10000-39357	222 S OXFORD AVE 1 ST FL	90004	10	138B193  1427	5517008023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.07046	-118.30775	CONVERT 1ST FL OF SFD TO OFFICES AND 2ND FL REMAIN RESIDENTIAL ;PERMIT WAS OBTAINED ON SEPARATE APPLICATIONPLAN CHECK IS FOR TITLE 24 ON THE 1ST FL AND OUTSIDE LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58636	15041-20000-24635	7267 N WHITSETT AVE	91605	2	186B161   626	2324002032	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM			PC Approved	07/31/2015 12:00:00 AM	ADDRESS	34.20313	-118.40527	plancheck for t24 energy. corridors in storage facility to repair fire damaged portion. 488 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58637	14041-20000-16600	14468 W MERCER ST	91331	6	201B149   200	2647027004	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.25015	-118.44828	PV1Install roof-mounted solar array on SFD. System size: 5kW(1) PowerOne PVI-5000-OUTD-US transformerless inverter(16) SunPower 327W pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58638	12041-10000-30146	8050 N MELBA AVE	91304	3	189B093   141	2020020014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.21671	-118.63396	New roof mounted P.V. system with 10.56 KWdc for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58639	14041-20001-05499	4632 N NATICK AVE 1-18	91403	4	168A149    80	2265002010	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Apartment			02/27/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.15544	-118.45402	((Expedite fees))PV2 FOR EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE 20KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58640	14041-20000-09806	338 S RENNIE AVE 1	90291	11	111B141   920	5018023056	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	33.99791	-118.47188	PV1.  Install 2.12 kW DC roof-mounted PV system, interconnect with main service panel.  (8) modules.  Microinverter standard plan - Enphase M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58641	14041-10000-08354	7216 S DALTON AVE	90047	8	102B193  1482	6018006012	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Expired	04/21/2016 12:00:00 AM	ADDRESS	33.97396	-118.30337	PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(12)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 300W]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58642	16041-10002-39321	6514 N BONNER AVE	91606	2	180B173   647	2336002013	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.18889	-118.37358	03/21/2017 Changes to an permitted set of plan. Changes include module layout. Changes has been clouded. ((((Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.1 kWac.  Central inverter system.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58643	15041-20000-38204	14760 W ARCHWOOD ST	91405	6	180B149   152	2236003012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.19276	-118.45518	PV1, roof mounted solar panel, 1.855kW DC system (7)modules #KU2656ZPA, (1)inverter:PVI-3.0-OUTD-S-US-Z-A  (E) INVERTER: FRONIUS IG 2000 NEG	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58644	16041-10003-14571	1616 W 209TH ST #1	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	33.84074	-118.3073	PC FOR CHANGES TO APPROVED SET. CHANGE TO MAIN BREAKER FOR TENANT. 60A MAIN. NO OTHER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58645	14041-20001-32780	14948 W ALTATA DR	90272	11	123B129   663	4411024020	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	34.03183	-118.5213	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 18KW DC/ 16KW AC USING A COMBINATION OF 2 CENTRAL INVERTER SYSTEMS AND A STRING OF MICROINVERTERS. USING ENPHASE M250 FOR THE MICROINVERTER. SYSTEM CONNECTS TO (E)600A SERVICE. 1PH-3W 120/240	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58646	19041-10000-29277	800 S WESTERN AVE	90005	10	132B193   736	5093008010	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Apartment			07/30/2019 12:00:00 AM	11/12/2021 12:00:00 AM		Issued	11/12/2021 12:00:00 AM	ADDRESS	34.05736	-118.30889	Full PC for Power & Energy. Scope includes a new 5000A 277/480V Service/Distribution board, new panels, new 30HP Fire pump, new circuits, and new lights. Total affected area is 77,000 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58647	16041-20000-42046	333 S GRAND AVE 38th Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	"Plan check for power and energy. TI to 38th floor office ~18,000sqft. New lighting (incl. emergency) and receptacles. New distribution load >400A.Plan is shared with application #16041-20000-42039 for the 37th floor.Applicant has only preventative maintenne information for ""emergency circuit"" with added connected load for both 37th and 38th floors. Based on provided information(replacement of emerency lighting for two floors). Client does not have to comply with 220.87 for emergency power per Supervisor Francis Ysaguirre."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58648	11041-10000-26311	2318 S LINCOLN BLVD	90291	11	108B149   373	4242001030	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM			PC Approved	12/09/2011 12:00:00 AM	ADDRESS	33.99437	-118.453	T24 Energy/Emergency lighting TI for 2-story retail/restaurant .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58649	15041-10000-31330	725 S FIGUEROA ST STE 1870	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.04886	-118.26071	Energy plan check for an office (#1870) T.I located in the 18th floor of a high rise building. Scope includes new lighting, receptacles, and equipment; Total area is 3400-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58650	16041-10000-23514	1351 N FIGUEROA PL	90744	15	033B201    19	7412009010	[Q]R3-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Harbor City		2943.02	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	PIN	33.78947513	-118.2836223	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 28.75KWac. FOR BLDG 1 & 2 (ADDRESS 1351 FIGUEROA ST)(130)MODULES(5)INVERTER-(1)100A PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58651	17041-10001-21334	5700 W WILSHIRE BLVD 4TH FLR	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM			PC Approved	04/27/2018 12:00:00 AM	ADDRESS	34.06218	-118.35303	SUPPLEMENTAL TO LOST SET OF PLANS - ADDED AREA TO TITLE 24 PLAN CHECKPC FOR OFFICE TI. TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 607 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58652	10041-10000-25689	4338 N LANKERSHIM BLVD	91602	4	165B177   571	2423016108	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	34.14903	-118.36479	NEW CONSTRUCTION OF A  (3) LEVELS SHOWROOM, VEHICLE SERVICE FACILITY, PARTS STORAGE AND OFFICES BUIDING WITH ROOF TOP PARKING DECK;	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58653	19041-20003-13745	5805 W 8TH ST ev2	90036	4	132B177   172	5089010024	R3-1-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	34.06086	-118.35605	09-25-2019 Changes to an approved set of plan. Changes include update calculation, and remove meter. All Changes has been clouded. Plan check only, permit covered under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58654	11041-20000-23370	6500 W WILSHIRE BLVD 23rd floor	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM			PC Approved	11/01/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	T.I. For and exisiting office space on the 23rd floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58655	16041-10000-03856	1269 W 184TH ST	90248	15	060B197    46	6109005003	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	33.86354	-118.29669	PV1, INSTALL 4.34KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGEL FAMILY HOUSE. (14) MODULES: LG 310N1C-G4(14) MICROINVERTER: ENPHASE 250W M250-2LL-60-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58656	16041-10000-40197	8947 N LEV AVE	91331	6	195B161   445	2628011015	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.23217	-118.41456	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.50KWac.(18)MODULES-CANADIAN SOLAR CS6K-280M(18)MICROINVERTERS-ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58657	19041-10000-52852	17326 W MARILLA ST	91325	12	201B129   247	2755015030	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.24745	-118.51237	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 38  (PLG 335W) MODULES, 38  (IQ7) MICROINVERTERS, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 12.730KW DC & 9.12KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58658	16041-20000-06278	20324 W VIA MEDICI	91326	12	219B113   127	2701045008	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Refund in Progress	08/31/2016 12:00:00 AM	ADDRESS	34.29431	-118.57691	"""0$ permit fees due to senate bill 1222""Install a roof-mounted solar array on a SFD. Interconnect with a 300A MSP.System size: 12kW (6+6). Ungrounded system. (52) 260W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58659	15041-20001-18439	10925 N OWENSMOUTH AVE	91311	12	210B105   210	2722004034	RE40-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.2686	-118.60231	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 11.4KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS. TOTAL OF 38 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58660	19041-20000-22233	22135 W ROSCOE BLVD LOT #32	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 32.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58661	14041-10000-23377	2234 S BARRY AVE	90064	11	123B149   399	4260014028	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.03402	-118.44606	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. NEW 600 AMP SERVICE. NO CHANGE OF USE. WAREHOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58662	17041-20000-01085	15301 W VENTURA BLVD 2nd Floor-Corridor	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/12/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for energy only. TI to existing corridor on 2nd floor of high rise building. New lighting (incl. emergency). 850sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58663	15041-10000-19236	8450 N VAN NUYS BLVD	91402	6	192B149   192	2638022039	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Info Complete	06/19/2015 12:00:00 AM	ADDRESS	34.22456	-118.44858	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 7611.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58664	15041-20000-28996	515 S FLOWER ST 51st Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	34.05134	-118.25661	Title 24 plan check only.  Total area = 690 sq. ft.  T.I. to existing commercial highrise.  New lighting for terrace room on 51st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58665	18041-10002-08441	1722 W 51ST PL	90062	8	108B193    42	5003005007	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Expired	10/18/2023 12:00:00 AM	ADDRESS	33.99587	-118.30763	SUPPLIMENTAL FOR THE ENERGY STORAGE SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58666	18041-20000-38105	1001 N SEWARD ST	90038	4	144B185   921	5532024007	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Closed	07/20/2020 12:00:00 AM	ADDRESS	34.08914	-118.33334	temporary power for construction site.  800 amp serive.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58667	14041-20000-06443	9146 S SEPULVEDA BLVD	90045	11	093B165    68	4124001005	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	33.9534	-118.39596	pc for t24 energy only. retail with new lighting. total area 1075 sq ft. permit to be issued under this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58668	17041-10000-03709	12424 W WILSHIRE BLVD SUITE 1055	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.04135	-118.47058	OFFICE TI, PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58669	10041-10000-05692												Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM			PC Approved	04/05/2010 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58670	14041-20001-23755	9999 W BARLING ST	91040	7	204B181   282	2543021002	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM			PC Approved	10/07/2014 12:00:00 AM	ADDRESS	34.25232	-118.34965	FEE IS ZERO PER SENATE BILL 1222.EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL GROUND MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(52) ET SOLAR MODULES P660250(2) POWER ONE PVI-6000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58671	13041-10000-28401	8401 N VAN NUYS BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.22308	-118.44896	Plan check for outdoor parking lighting of four new buildings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58672	18041-20000-18795	20641 W CHESTNUT CIR (#269)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	12/22/2018 12:00:00 AM	ADDRESS	34.29346	-118.58389	Plan check for a PV1 roof-mounted PV system. System size is 2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58673	14041-20000-18893	10816 W BURBANK BLVD	91601	2	174B173  1016	2416014025	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			07/14/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.172	-118.3665	CHANGE OF USE FROM OFFICE TO DANCE STUDIO WITH INTERIOR TI. pc for T24 energy only. new lighting and room partitions. per building submittal, plan check in accordance to 2008 energy efficiency standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58674	19041-20000-27918	5200 N LANKERSHIM BLVD Suite# 130	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	10/21/2021 12:00:00 AM	ADDRESS	34.16511	-118.37448	Distribution, power, and lighiting for commercial tenant improvement.  Plan check for power and energy.  BUILDING PERMIT UNDER 19016-20000-22198	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58675	14041-20001-12166	1620 W 237TH ST 1-10	90710	15	042B193   528	7439007029	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Apartment			06/26/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	33.8103	-118.30766	Changes to an approved set of plans. Master application #14041-20000-12166. Changing 600A service to 800A.Previous work description.New 3-story 10-town home apartment building.  Units 1-10 typical per applicant.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58676	16041-20000-40571	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Closed	08/30/2022 12:00:00 AM	ADDRESS	33.76094	-118.29308	TI to (E) Target retail store.  Additional display lighting for liquor aisles.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58677	19041-10001-51535	811 E AMOROSO PL	90291	11	108B149   718	4241025019	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			PC Approved	01/04/2021 12:00:00 AM	ADDRESS	33.99282	-118.45847	(off-hours fees)plan check for PV-1, system size is 7.19KW, solar tile system. (2) inverters, first (5.2KW) and the second (3.8KW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58678	13041-10000-21148	12652 W VILLAGE LANE bldg #2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58679	18041-20000-42330	22248 W COHASSET ST pv1	91303	3	186B101   402	2023021015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.2065	-118.61202	pv1install roof mounted pv system sized 3.8KW AC interconnetced with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58680	11041-20000-16210	1220 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/08/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29232	"New 3.23 Kw Pv solar equipment ( max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) system for an apartment Bldg"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58681	15041-10000-30837	7059 W SUNSET BLVD	90028	13	147B181   582	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Issued	11/12/2015 12:00:00 AM	ADDRESS	34.09813	-118.34347	T24 ONLY PC FOR  JIMMY JOHN'S SHOE. T.I. TOTAL AREA 1656 SQ FT. ADDITION OF TWO PANELS LESS AND EQUAL TO 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58682	17041-20000-06913	5826 N TUJUNGA AVE	91601	2	174B173   197	2337016001	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Apartment			03/03/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.17649	-118.37885	Plan check for a Title 24 only. Project site is an existing apartment building. Project scope is outdoor lighting. Total lighting area = 1,531 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58683	14041-10000-28660	750 N HARPER AVE	90046	5	141B173   236	5528006027	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			Reviewed by Supervisor	12/11/2014 12:00:00 AM	ADDRESS	34.08519	-118.36894	PV1, INSTALL 4.335 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY-HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(17) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58684	13041-10000-23372	3267 W OLYMPIC BLVD	90006	10	129B193   228	5080008033	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.05282	-118.30814	Remodel and change of use of 2-story building from coffee shop/retail to bank.  Title 24 plan check only for 2nd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58685	16041-10000-19318	1417 N GLENDALE BLVD	90026	13	141A209   273	5419019017	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1956.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.08055	-118.26039	PC for T-24 only, Remove HID fixtures and replace to LED fixtures. Using existing branch ckt. Total area: 1,749 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58686	10041-10000-25070	13506 W SHERMAN WAY	91405	2	183B157    80	2328034027	C1-1VL, R3-1, R4-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Expired	01/04/2013 12:00:00 AM	ADDRESS	34.20102	-118.42711	Installing one panel and 17 devices in a one story commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58687	19041-10000-21605	14218 W AETNA ST	91401	6	177B153   823	2240025012	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	06/13/2020 12:00:00 AM	ADDRESS	34.18007	-118.44268	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58688	11041-10000-02211	2730 E WASHINGTON BLVD	90023	14	118-5A219 140	5169028012	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	09/28/2011 12:00:00 AM	ADDRESS	34.01717	-118.22199	INSTALL A NEW ABOVE GROUND 12,000 GALLON DIESEL STORAGE TANK FOR THE TRUCKS IN AN INDUSTRIAL FACILITY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58689	11041-10001-23716	19749 W DEARBORN ST	91311	12	198B117   164	2761001055	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	02/10/2012 12:00:00 AM	ADDRESS	34.23748	-118.56389	Changes from previously approved plans.  All changes note by DELTA-1 as shown on plans.   (Note: previously approved plans submitted for reference only)*****T. I. - Office space and film editing, check power and energy.(TENANT IMPROVEMENT IN 2ND FLOOR OFFICES:  (N) INTERIOR WALLS, CEILING WORK AND FINISHES TO CREATE OFFICES.  NEW TRANSFORMER AT SECOND FLOOR AND NEW A/C UNIT AT ROOF LEVEL.)*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58690	16041-20000-06777	10621 N AQUEDUCT AVE	91344	12	207B141   922	2661001***	RD6-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.26284	-118.47359	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58691	15041-30000-39806	14006 W RIVERSIDE DR Space FC5	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Title 24 plan check only.  Total area = 330 sq. ft.  T.I. to Burger King restaraunt.  New lighting, HVAC, and cooking equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58692	19041-10000-19585	1715 N BARDALE AVE	90731	15	024B193   275	7442012004	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	33.7603	-118.30052	(ePlan) PV1. New 7.260 kW DC/ 6kW AC rooftop solar system on an (E) SFD. Install  (22) roof mounted PV solar panels, (22) P400 optomizers, (1) 6 kW inverter. System connect to  (E) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58693	15041-10000-26080	10201 W PICO BLVD 5TH FLR	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	PIN	34.05182951	-118.41257696	PC FOR ENERGY. T.I FOR OFFICE. NO CHANGE OF USE. TOTAL AREA 39550 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58694	19041-10000-35851	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			PC Info Complete	11/27/2019 12:00:00 AM	ADDRESS	33.74512	-118.26099	Power plan check for a new Bio trickling filter air clean up system located in a hazardous location. Scope (1) 600-Amp panel, (4) motors and other associated equipments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58695	14041-20000-35476	24374 W WELBY WAY	91307	12	183B089   741	2034005039	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.19393	-118.65649	NEW PV SYSTEM DESIGN. SYSTEM IS NOW A 9KW AC USING 2 TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING 32 MODULES IN TOTAL. SYSTEM USES POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58696	14041-20000-36041	5670 W WILSHIRE BLVD Suite 700	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for energy only. TI to office on 7th floor of high rise office building. New receptacles and lighting (incl. emergency). 4,095sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58697	16041-20000-18213	6600 N TOPANGA CANYON BLVD space 68	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Issued	07/27/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	"PLANCHECK FOR POWER AND ENERGY PER APPLICANT. Tenant improvment of (e) retail space. 'Garage "" unit sp# 68 .building permit #16016-20000-11972"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58698	19041-20000-51104	3333 S MANNING AVE	90064	5	123B161   812	4316032011	R3-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	06/16/2021 12:00:00 AM		Permit Finaled	02/17/2023 12:00:00 AM	ADDRESS	34.03112	-118.40638	T24 PLAN CHECK, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE =  3894 SFB#19016-20000-39587	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58699	18041-10001-28695	11558 W DONA TERESA DR	91604	2	159B169   522	2381012002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2018 12:00:00 AM			PC Approved	09/25/2018 12:00:00 AM	ADDRESS	34.13099	-118.38537	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE UPSIZING POWER OPTIMIZERS FROM P320 TO P400 AND CHANGING PANELS FROM CANADIAN SOLAR 325 TO 330	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58700	12041-10000-19675	1327 E WILLOW ST	90013	14	126A217    73	5164006007	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM			Reviewed by Supervisor	09/07/2012 12:00:00 AM	ADDRESS	34.03938	-118.23179	New 13.8kw photovoltaic system for an existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58701	14041-20000-35394	733 N HUDSON AVE	90038	4	141B185   445	5533036007	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			12/23/2014 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.0844	-118.33219	NEW APARTMENT. 46 UNIT. FIRE ALARM VARIANCE HAS BEEN FILED. LOCATION IN METHANE ZONE. DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58702	14041-20001-30449	8031 N WILLIS AVE	91402	6	189B149   231	2209039031	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	34.21672	-118.45551	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP. System size: 7.31kW.34 EnPhase M215 microinverters connected to 34 250W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58703	17041-10000-41884	647 N BEACHWOOD DR 1-52	90004	4	141B189   407	5523022013	C2-1VL	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	01/19/2022 12:00:00 AM	ADDRESS	34.08303	-118.32194	FULL PC FOR POWER AND AND ENERGY FOR A NEW 5- STORY OVER 1- LEVEL BASEMENT MIXED USE PROJECT WITH 52- RESIDENTIAL UNITS AND GROUND FLOOR COMMERCIAL SPACE. SCOPE INCLUDES A NEW 2500A 208/120V SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 50902 SQ. FT.  B#17010-10000-02156	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58704	18041-10000-20354	1607 E PLEASANT AVE #2	90033	14	129A221    80	5174024026	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.04838	-118.22052	PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT COMPLEX. CONISIT OF 14 MODULES(QPEAK-G4/SC305) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 4.27KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58705	15041-10000-27523	7192 W FORMOSA FUSION CT	90046	5	141B181  1714	5525003039	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08554	-118.34584	PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58706	14041-10001-35665	921 W VENICE BLVD	90015	1	126A203   113	5135030011	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.04013	-118.27572	10-27-15Changes to an approved set, note changes on delta 2. Changes include replacement to LED fixtures.  (((Plan check for power and energy. Project site is a new 3-story building (warehouse). Total lighting area = 15,187 sq. ft. New 800 amp service. Installation of a new 800 amp-rated switchboard and (4) panels.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58707	18041-10000-48482	4615 N KESTER AVE	91403	4	168A149   140	2264020028	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			12/21/2018 12:00:00 AM			PC Info Complete	05/29/2019 12:00:00 AM	ADDRESS	34.15437	-118.45765	NEW CONSTRUCTION OF A 4-STORY (11)-UNIT BUILDING WITH SUBTERRANEAN LEVEL PARKING AND ROOF DECK. SCOPE INCLUDES FULL PC OF PWR AND LTG. 1000A ,120/208V, 3PH. B# : 18010-10000-04216AUTOMATIC SPRINKLER SYSTEM (NFPA 13). BASEMENT CONSISTS OF TYPE 1-A CONSTRUCTION, GROUPS S-2. FLOOR 1 CONSISTS OF TYPE 1-A CONSTRUCTION, GROUPS S-2, R-2. FLOORS 2, 3, 4 AND ROOF DECK CONSISTS OF TYPE V-A CONSTRUCTION, GROUP R-2. with 20% density bonus, 5 % very low income unit. pwer 12.22A.25	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58708	17041-20000-36371	20637 W GRESHAM ST	91306	3	195B109   103	2780009004	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.23071	-118.5832	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58709	12041-10000-21689	835 W BLOOM WALK	90089	9	118-5A201  22	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM			PC Approved	10/01/2012 12:00:00 AM	ADDRESS	34.01948	-118.2876	TI in an existing office & lab. for USC. EPC is for T24. (STUFFER HALL OF SCIENCE)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58710	19041-10000-30776	8851 N LAUREL CANYON BLVD	91352	6	195B165   433	2634011900	OS-1XL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1210.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.22978	-118.40177	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58711	18041-10000-36430	1715 E 21ST ST	90058	9	118-5A213 212	5167014017	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.01778	-118.24226	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58712	18041-10001-08362	10314 N WOODWARD AVE	91040	7	204B193   603	2559008020	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2018 12:00:00 AM			PC Approved	05/10/2018 12:00:00 AM	ADDRESS	34.25645	-118.30689	$0.00 due to senate bill 12222PC for rooftop solar 6.48kW(ac) system for SFD. Intalling 18 AC modules and 125A load center. Connecting system to 5.8kVA (5Kw)Tesla powerwall covered under 18041-10003-08362. SOLAR PV PERMIT FEES COVERED UNDER 18041-90000-08362.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58713	18041-10000-45667	12025 W VOSE ST	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.19855	-118.3952	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58714	16041-10001-02777	2968 W 6TH ST	90005	10	135A201   140	5077007029	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Apartment			11/16/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Closed	11/30/2016 12:00:00 AM	PIN	34.06352386	-118.28606577	11/16/16Changes to an approved set of plans. All changes are made under delta 3. Changes inlcude adding 4 FA devices revising battery calculations, and relocating FA devices on the floor plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58715	14041-20000-24866	7006 S HOOVER ST UNIT 7	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #7.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58716	17041-10000-18117	1400 W PICO BLVD	90015	1	127-5A203 230	5135034025	CM-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Issued	05/31/2017 12:00:00 AM	ADDRESS	34.04329	-118.27427	PC for T24 only for removal of outdoor metal halide fixture and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58717	16041-20001-30884	3624 S 5TH AVE	90018	10	120B189  1373	5044030021	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM			PC Approved	09/16/2016 12:00:00 AM	ADDRESS	34.02208	-118.32226	EXPEDITE PER APPLICANT.PV1ADDITION TO AN EXISTING SYSTEM.6KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58718	11041-10000-12557	16624 W VENTURA BLVD	91436	5	168B137   819	2284007016	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.1578	-118.49544	New restaurant in existing building.  First time tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58719	18041-20000-45263	2840 W SAN FERNANDO ROAD	90065	1	150B213    59	5457003018	[Q]M2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Corrections Issued	12/27/2018 12:00:00 AM	ADDRESS	34.11065	-118.24419	Plan check for PV Feed In Tariff(FIT) roof mounted system install in to existing FIT system. Addtion PV FIT size: 327.1 kW DC, 296.4kW AC CEC. Total PV modules 884 and 4 inverters(3phase 66.6kW, 33.3kW, 20kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58720	18041-20000-41108	11869 S TEALE ST	90230	11	105B165   394	4220006065	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	33.98458	-118.4024	Plan check for a fire alarm system for a 3-story commercial building. Fire alarm consists of (1) FACP and (47) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58721	19041-10000-16247	1019 E 4TH PL	90013	14	127-5A217  60	5163018006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.04195	-118.23327	PC FOR FIRE ALARM SYSTEM REPLACEMENT. SCOPE INCLUDES NEW FACP, NEW ANNUNCIATOR AND 105 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58722	17041-10000-15398	433 S SPRING ST	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	Replacement of fire alarm system for 12 story office building core and shell.  Highrise voice evac system.  Total system size = 821 devices + 18 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58723	19041-10000-44016	1875-1925 CENTURY PARK EAST	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	PIN	34.06084104	-118.41471001	T-24 ENERGY PLAN CHECK ONLY, AREA OF SCOPE IS (15,831)SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58724	17041-20000-34236	20801 W VENTURA BLVD	91364	3	171B109    62	2166033054	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.16663	-118.58589	Install new LED fixtures on (E) poles in (E) commercial parking lot.  No new or altered circuits.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58725	16041-10002-39176	3150 W WILSHIRE BLVD STE 100	90010	10	132B197    39	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	02/04/2018 12:00:00 AM	ADDRESS	34.06163	-118.29086	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED ON PLANS. EXIT SIGNS SHALL BE DUAL CIRCUIT TYPE WITH A NORMAL LINE AND AN EMERGENCY LINE COMING FROM BUILDIN GENERATOR. PART OF HIGH RISE. INSTALLING NEW TRANSFORMER AND SUBPANEL FOR EMERGENCY CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58726	10041-10000-10421	970 W 190TH ST suite 370	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	33.85812	-118.29302	Ti in an existing office in a highrise building. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58727	16041-20001-26478	11022 BENJAMIN LANE	91344	12	210B137   947		(T)(Q)RD6-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Issued	09/13/2016 12:00:00 AM	PIN	34.2712139	-118.48754573	((9/13/2016))CHANGES TO AN APPROVED SET OF PLANS.  ADDITION OF (1) KYOCERA MODULE KU2656XPA.TOTAL MODULES 14. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58728	13041-10001-33712	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.09818	-118.32309	Chage to approved set by reconnecting the temp load to a new Temp switchboard (3000-Amp), new switchboard will be installed in new location. All changes are under Delta-1 only and all load are remained in the same.(((TEMPORARY POWER  FOR TENANT IMPROVEMENT CONSTRUCTION FOR 4 SEPERATE BUILDINGS.Note: Approval of columbia square building (board MSRH) fed from the temp board for now is approved under 13041-10000-11563.  Once temp power is removed MSRH will be fed by it is own service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58729	15041-20000-36004	2367 W 21ST ST	90018	10	126B189  1152	5073026008	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Expired	11/24/2017 12:00:00 AM	ADDRESS	34.0382	-118.31681	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac. (10)MODULES-TRINA SOLAR TSM-255 PD05.05(1)INVERTER-ABB PV1-3.0-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58730	13041-10000-32763	11738 W COURTLEIGH DR	90066	11	111B161   724	4233023025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	33.99872	-118.4175	New 3 story, 23 unit apartment over parking garage.  Install new 1000A service, 120/208, 3Ph, 4W.   Plan check for power and energy.  Variance to separate fire alarm is submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58731	18041-20000-08187	634 S SAN JULIAN ST	90014	14	127-5A213 523	5148025901	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	11/01/2021 12:00:00 AM	ADDRESS	34.04195	-118.24667	Plan check for power and energy. Project site is an existing commercial building. Project scope is a complete remodel. Total lighting area = 10,452 sq. ft.Note: Building application has been generated under 18014-20000-01208. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58732	15041-10000-27009	13604 W SHERMAN WAY	91405	2	183B157    75	2328008074	(Q)RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.20102	-118.4293	PC for new Fire alarm system, (165) devices, (1) FA panel, (1) communication panel. 5-level apartmetn bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58733	17041-20000-28777	8620 N SAN FERNANDO ROAD	91352	6	192B173    86	2632028002	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.22625	-118.37845	Plan check power only. Project site is an existing fuel dispenser station. Project scope is power for (2) new fuel dispensers.Note: Building application has been generated under 17020-10000-01726	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58734	19041-20001-00961	9703 S EVERS AVE pv1	90002	15	093A213   404	6048006021	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	33.94813	-118.24726	CHANGES TO APPROVED SET - CHANGES INCLUDE RELOCATION OF INVERTER AND ADDITIONAL DISCONNECT FOR BATTERY BACK UP SYSTEM pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.  (1) tesla battery 5KWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58735	19041-10000-48025	777 W 190TH ST	90248	15	060B201    48	6121021011	[T][Q]M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	33.86037	-118.28753	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58736	12041-10000-29116	7430 W 87TH PL	90045	11	096B157   694	4119002015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	33.9583	-118.42597	PV1 AC-OUT 3.672KW (DC-OUT 4.16KW) ROOF-MOUNT ENPHASE MICROINV (m215-60-2ll-s22) STD PLAN 1 STORY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58737	13041-20001-15068	10817 W SHERMAN WAY	91352	2	183B173    89	2410019044	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.20136	-118.36644	10/25/2016 Changes to an approved set of plans. All changes have been clouded. Equipment has been added to distribution boards.*****Previous Work Description*****Plan check for industrial/office use building. Existing service, new panels and loads. Recalculate fees at final.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58738	19041-10000-49357	10516 N VARIEL AVE	91311	12	207B105   549	2706018038	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.2614	-118.59279	[EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 6.03KW DC/ 7.6KW AC, INCLUDING 18 MODULES (LG3355N1C-V5), 18 POWER OPTIMIZERS (P370),  AND CENTRAL INVERTER (SE7600A).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58739	19041-10000-35374	2913 W EXPOSITION PL Units 3	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02048	-118.32811	Plan check for a PV2 2.56kw DC / 3.0KW AC roofmounted system. Scope includes (8) modules and (1) inverter interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58740	18041-10000-41402	6245 W WILSHIRE BLVD #102	90048	5	135B177   483	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.06356	-118.36478	Full plan check for a 1st time restaurant T.I. Scope includes a total area of 1262-SQ FT. Suite #102.Building Permit: 18016-10000-32932	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58741	16041-20000-32662	1533 N VISTA ST	90046	4	147B181   527	5550013012	R3-1	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Apartment			09/14/2016 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/11/2022 12:00:00 AM	ADDRESS	34.09899	-118.3512	New 4-story, 4-unit apartment building with 1 level subtarranean parking. 600A service.Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58742	15041-20001-16294	936 S OLIVE ST UNIT 350	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #9 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58743	11041-10000-13927	6291 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.18382	-118.60178	BRAND NEW 3-STORY PARKING STRUCTURE.  FULL PLAN CHECK.  Variance to separate the Fire alarm system was submitted on August 12, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58744	13041-10000-27825	380 W WORLD WAY SPC T52	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	INSTALLING (4) ILLUMINATED SIGNS INSIDE LAX TBIT SPC T52.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58745	15041-10000-32932	2001 S ALAMEDA ST	90058	9	118-5A215  80	5167014008	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.01787	-118.23982	plan check for additional CU and FC UNITS  and Circuits THAT WERE INSTALLED WITHOUT PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58746	14041-20000-32886	13213 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM			PC Info Complete	02/10/2015 12:00:00 AM	ADDRESS	34.31094	-118.42882	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING (RESTAURANT). NEW LIGHTING, NEW CIRCUITS TO EXISTING PANEL. TOATL SQFT 2450. PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58747	12041-10000-22405	4550 W PICO BLVD SUITE #301	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	Plan check power and energy for first time tenant. Ross retail store. Core and shell plan check under #07041-10000-11169	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58748	18041-10000-09744	1816 N VERMONT AVE STE1/2&3/4	90027	4	150B197  1082	5590020002	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.10411	-118.29162	PLAN CHECK FOR TITLE 24 ONLY FOR - CHANGE OF USE FROM (E) 915 SF RETAIL TO BAR AND 3161 SF RETAIL TO RESTAURANT AND BAR WITH UNCOVERED OUTDOOR DINNIG. - TOTAL AFFECTED AREA = 1008 SQ. FT. & 3077 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58749	13041-20000-01514	2706 W WILSHIRE BLVD basement	90057	1	133-5A201  94	5141011016	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.06093	-118.28296	Install circuits and outlets for repaired building.  Basement only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58750	17041-20000-09781	12739 W VAN NUYS BLVD	91331	7	210B161    29	2533019032	[Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.27542	-118.41112	Remove recessed under canopy fixtures (fluorescent T12s) and replace with same quantity LED fixtures.  Plan check for energy.  Building permit filed under 17016-20000-01892	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58751	14041-10000-24888	3494 E PICO BLVD	90023	14	118-5A225 320	5190036804	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.0179	-118.20314	Title 24 plan check only.  Total area = 1200 sq. ft.Remodel existing conference room and add new training and conference rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58752	19041-20000-23681	10418 N NEVADA AVE	91311	12	204B101    43	2723017105	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.25942	-118.60914	Plan check for PV roof mounted system, system size: 13.2KW DC, 12.04KW AC with 44 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58753	17041-20000-32165	23251 W CHASE ST	91304	12	192B093    64	2005014028	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.22364	-118.63404	"""0$ permit fees due to senate bill 1222""Plan check for roof-mounted solar pv system with AC coupled battery backup system.10.4kW ungrounded pv system [(1) 6.6kW + (1) 3.8kW].(34) 325W pv modules. (2) 5kW Tesla Powerwall 2s."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58754	17041-10000-00284	15554 W ROSCOE BLVD	91406	6	192B145   440	2654038016	[Q]CM-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.22123	-118.47149	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA (OUTDOOR) 12400 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58755	14041-20000-12273	445 S FIGUEROA ST Floor 30	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM			PC Approved	05/08/2014 12:00:00 AM	ADDRESS	34.05295	-118.25675	Common area (corridor and elevator lobby) renovation on the 30th floor of a commercial highrise building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58756	11041-10002-04593	6401 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Info Complete	09/23/2011 12:00:00 AM	ADDRESS	34.18624	-118.59778	Modification to a previously approved plan.  Changed routing and conductor size to main panel.  Changed panel name, relocated equipment and added two pieces of new equipment.  <<<<CHANGE OF USE FROM RETAIL TO GYM ( LA FITNESS )>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58757	18041-20000-03988	621 S WESTERN AVE	90005	10	135B193   955	5503031019	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			PC Approved	02/02/2018 12:00:00 AM	ADDRESS	34.0628	-118.30928	Tenant improvement to (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58758	15041-20000-01704	7870 N VAN NUYS BLVD	91402	6	189B149   645	2212028013	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.21426	-118.44738	PC FOR EMERGENCY SYSTEM. RELOCATION OF LOADS FROM ONE LOAD CENTER TO ANOTHER. UPGRADE GENERATOR. AND RELOCATE FEEDS. PC FOR POWER ONLY. NO NEW LIGHTING, NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58759	13041-10000-25576	1533 N MARLAY DR	90069	4	148-5A175 320	5556031008	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.10004	-118.36934	PV PLAN-CHECK ONLY. PERMIT ALREADY EXIST UNDER #13041-10000-03081.PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 8.085 KW DC ON NON-STANDARD PLAN IN A TWO-STORY HOME WITH POWER OPTIMIZERS & LOAD CENTER. (33) MODULES: CANADIAN SOLAR #CS6P-245P(2) INVERTER: SOLAREDGE #SE3800A-US(33)OPTIMIZERS: SOLAREDGE #OP250-LV-MC4SM-2NA-Z	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58760	17041-10000-38547	9753 N SUNLAND BLVD	91040	7	201B177   231	2543032022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.24724	-118.35395	INSTALL NEW ROOFTOP SOLAR SYSTEM ON A SFD, 9KW AC SYSTEM WIRH (28) AC MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58761	14041-20000-23870	6454 N CLYBOURN AVE	91505	2	180B177   194	2414034009	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	PIN	34.18835528	-118.36335307	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(16) SUNPOER 327W MODULES(1) POWER ONE PVI-5000-OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58762	12041-10000-00758	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Approved	01/12/2012 12:00:00 AM	ADDRESS	34.06222	-118.35208	Change of lighting and new circuits for outlets.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58763	13041-10002-22680	1550 N WILCOX AVE	90028	13	148-5A187 338	5546013002	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.09947	-118.33087	lighting change to approved set, and  all change apply to delta 1 only.(((EXISTING MIX USE. RENOVATION OF ENTIRE ELECTRICAL SYSTEM. NEW SERVICE. PC FOR POWER AND ENERGY. TOTAL AREA ABOUT 20K SQ FT.( FIRE ALARM VARIANCE HAS BEEN FILED). NON METHANE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58764	14041-20001-28347	22441 W HARTLAND ST	91307	12	183B101   703	2024029010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM			Corrections Issued	10/21/2014 12:00:00 AM	ADDRESS	34.19474	-118.61627	FEE EXPEDITEPV1 SFD. TOTAL SYSTEM SIZE 11.5KW AC USING 2 CENTRAL INVERTERS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58765	15041-10000-17994	1026 S BROADWAY BLDG A	90015	14	126A209    92	5139014017	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.04029	-118.25788	FEES ARE $0 DUE TO SENATE BILL 1222.PV2, ROOF MOUNTED SOLAR SYSTEM TO AN APARTMENT BUILDING TOTAL SIZE 155KW. ( 598) MODULES INNOTECH ECO PLUS POLY-UP260.(2) PV INVERTERS SOLECTRIA PV1 75KW-PEChange to plan set done under suppliemental permit 15041-10001-17994.  Permit to be pulled under master application 15041-10000-17994.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58766	19041-20000-27850	2021 N PARK DR	90026	13	144B213   846	5415009007	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Issued	07/19/2019 12:00:00 AM	ADDRESS	34.08707	-118.24726	Plan check for PV roof mounted system, system size: 4.8KW DC, 4.39KW AC  CEC with 16 PV Modules and 1 inverter(3.8KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58767	17041-10000-36540	6238 W 6TH ST	90048	5	135B177   394	5510026023	R2-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Expired	09/08/2023 12:00:00 AM	ADDRESS	34.06514	-118.36465	PV1, NEW ROOF MOUNTED SOLAR SYSTEM INTERCONNECTED WITH AN ENERGY STORAGE SYSTEM. (18) MODULES, (1) INVERTER5KWACC, (1)TESLA AC POWERWALL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58768	15041-10000-30213	3035 W OLYMPIC BLVD 2nd Floor	90006	10	129B193   263	5080032011	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM			PC Info Complete	09/14/2015 12:00:00 AM	ADDRESS	34.05278	-118.30144	PC for energy only, t-24 to an existing commercial building. Scope of work: adding lighting fixtues, and receptacles. sq ft = 5005	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58769	17041-20000-33488	9363 N SHOSHONE AVE	91325	12	198B129    98	2766020027	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.2412	-118.5179	Plan check for solar pv system, roof-mounted array on SFD.10.4kW ungrounded system [3.8+6.6].(33) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58770	19041-10000-10642	3030 W 8TH ST #200	90005	10	132B197   465	5094012029	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.0576	-118.29246	Replace fluorescent troffers with new LED retrofit kits (Indoor Only). Total affected area is 6830 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58771	16041-10000-40657	5101 N SEPULVEDA BLVD	91403	4	171A145    69	2263001902	PF-1XL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.16312	-118.46639	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58772	16041-10000-33360	2324 E WHITTIER BLVD	90023	14	124-5A221 290	5189006061	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.03431	-118.21621	PC for T24 only for Restuarant with  2322 sqft. Installing new lights and receptacles.**NEW WALLS, TILE, KITCHEN EQUIPMENT, SEATS, NEW HOOD; TI CHANGE OF USE FROOM RETAIL TO RESTAURANT; ATTN MOHAMMAD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58773	13041-10000-04705	22037 W GLEDHILL ST	91311	12	198B101   105	2727016027	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.2418	-118.60754	PV1 Plan check for new roof mounted photovoltaic system for two-story dwelling. Total system size: 11.75KW. Transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58774	15041-10001-31014	12457 W VALLEY VISTA WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM			PC Approved	11/19/2015 12:00:00 AM	ADDRESS	34.30841	-118.4059	Expedite per applicant request.((PV1, roof mounted solar, 5.72 kWDC, adding new 125A subpanel for solar system to existing 200A panel, new utility lockable AC disconnect (22) modules: Hyundai solar HiS-S260RG(22) microinverters: Enphase M215-60-2LL-S22-IG))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58775	16041-10000-20653	11111 W BURBANK BLVD	91601	2	174B173   943	2337029029	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.17233	-118.37285	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT, INTERIOR AND EXTERIOR ALTERATION TO (E) RETAIL/CONVENIENCE STORE (7 ELEVEN). SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 334 SQ. FT. B#16016-10000-04592	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58776	14041-20000-14445	9454 N MARLEY WAY	91343	7	198B149   631	2650034***	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.24228	-118.45749	PV1.  Install 8.5 kW roof-mounted utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58777	19041-20000-31566	7338 N VINELAND AVE	91352	2	186B173   873	2410018002	RD2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.20406	-118.37002	PV1.  Install 8.28 kW roof mounted grid tied PV system.  (23) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58778	12041-10000-12284	1800 N WHITLEY AVE 1-32	90028	4	150A187   372	5547005008	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Apartment			05/29/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.10353	-118.33319	New Fire Alarm System for 5 story condo.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58779	13041-10000-14619	6022 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	33.94182	-118.39269	PLAN CHECK FOR POWER AND ENERGY FOR PHASE 6.  AMERICAN AIRLINE PREMIUM SERVICES LOUNGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58780	13041-20000-00569	23016 W MARIANO ST PV-1	91367	3	171B097   138	2042010038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.16814	-118.62839	PV_1. Armentrout Residence. 5.52kW. Transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58781	11041-20001-00534	2850 W RIVERSIDE DR	90039	4	151-5A207  63	5438025011	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.10998	-118.26339	Plan check for revision to approved plans. Revision to point of connection from supply side to load side. Derate main overcurrent protection from 400A to 200A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58782	13041-10000-03200	7508 W MELROSE AVE	90036	5	141B177   659	5526017027	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Expired	03/04/2015 12:00:00 AM	PIN	34.08337436	-118.35354775	Fire alarm system for grocery storewith 10 devices and 1 fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58783	18041-20000-12707	11239 W VENTURA BLVD Unit 221	91604	2	162B173   294	2366035036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM	07/02/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.14181	-118.37523	Medical office TI.  Plan check for power and lighting.Building permit under 18016-20000-00817.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58784	16041-20000-45103	1745 N WESTERN AVE	90027	13	148-5A193  44	5544005028	C4-1D	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			12/23/2016 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.10305	-118.3096	Plan check for power and energy. Project site is a 24-unit mixed use building: 3 levels of residential over 1 level of retail with 1 level of existing basement parking garage. Total lighting area = 32,574 sq. ft.Note: Building application has been generated under 16016-20000-21115	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58785	13041-10000-05460	1492 S LORENA ST	90023	14	117A223    18	5190031026	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.01676	-118.20886	SERVICE UPGRADE AT TRUCK GAS STATION.  NEW 1200 A SWITCHBOARD, 1000 A MOTOR CONTROL CENTER, AND 400 A SUBPANEL.  APPLICANT CLAIMS NO HAZARDOUS LOCATIONS WITHIN SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58786	19041-20000-01201	19535-19543 W CARDIGAN DR	91324	12	198B117   258	2761035101	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			01/10/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.23884	-118.55932	PLAN CHECK FOR POWER ONLY. NEW 5 UNIT TOWNHOUSE BUILDING WITH ATTACHED GARAGES (1 HOUSE METER AND 5 UNIT METERS)existing 600A 120/240V 1P/3W Servicebuilding permit # 18010-30000-01136	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58787	13041-10000-19453	2118 N SUNSET CREST DR	90046	4	150B169   192	5564020005	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.11087	-118.39027	PV1.  Install 6.72 kW DC roof-mounted solar array, interconnect with main service panel.  {Transformerless inverter: SolarEdge SE6000A-US} {28 modules: Trina Solar TSM-240PA05}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58788	14041-20000-31653	12886 N GLENOAKS BLVD	91342	7	222B153   285	2508016015	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.30489	-118.44588	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(16) SUNPOWER 327W MODULES(1) POWER ONE PVI 5000 TL INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58789	14041-10000-17971	114 E 2ND ST	90012	14	130-5A213 197	5161026024	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/02/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.05056	-118.24413	New manual and automatic fire alarm system for existing restaurant space.  System size = 67 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58790	13041-10000-33932	4550 W PICO BLVD PETSMART	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	"A REDUNDANT FIRE ALARM SYSTEM FOR ""PETSMART"" STORE TO BE IN COMPATIBILITY WITH EXISTING FA SYSTEM FOR THE 3 LEVELS OF THE BUILDING. ""COMPLY WITH DEPARTMENT ORDER effective date06/17/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58791	18041-10000-25261	3435 W WILSHIRE BLVD 14th floor	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.06194	-118.29866	Add Fire alarm devices to existing Fire Alarm system on (E) 14th floor Office space. (2) Control panels, (86) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58792	15041-10000-01391	5026 W ROSEWOOD AVE 1-22	90004	4	141B189  1099	5522021007	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			01/16/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.07919	-118.31445	New 4 story 22 unit apartment with 6 typical units and 1200 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58793	16041-10000-09969	7000 W MELROSE AVE	90036	5	141B181   665	5525017019	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM			Reviewed by Supervisor	03/29/2016 12:00:00 AM	PIN	34.08317504	-118.34295683	Full PC for a mixed used new 40 unit apartment. 3 levels of subterranean parking, and 2 levels of apartment use, plus roof level. New 1000 A service. Typical units not specified. Total sq ft =  69126	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58794	18041-10000-19334	10250 W SANTA MONICA BLVD #FC20	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for Energy only (T24) for food service kiosk (Fala Bar) and its remote storage in Westfield Century City. Storage area loads will be fed from existing panel, kiosk area loads will be fed from new 100A panel. Total new load < 200A, New lighting is only done in the kiosk area. Total area for T24 scope is 343 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58795	13041-10000-26738	1847 N KINGSLEY DR	90027	13	150A195   185	5544010016	R3-1	Central	Hollywood	Greater Griffith Park		1904.01	Electrical	Electrical	Apartment			09/26/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Expired	11/05/2015 12:00:00 AM	ADDRESS	34.10491	-118.30367	REPLACEMENT OF AN OLD NON-WORKING FIRE CONTROL PANEL WITH NEW COMPATIBLE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58796	13041-10001-35647	6007 N MELVIN AVE	91356	3	177B117   647	2153023001	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.17953	-118.56028	Expedited RSES plan check per applicant request.{{PV1, Install 11.75 kW DC roof-mounted solar array for a one story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (47) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58797	13041-20000-24246	550 S BEVERLY GLEN BLVD	90024	5	138B157    95	4359015020	RE20-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.07178	-118.43165	New 13kw Photovoltaic system for an existing single family dwelling.  Rooftop system.  System is UNGROUNDED.  Plan check/permit are for PV system only, Not for service panel upgrade or derating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58798	15041-20000-16321	8434 N WILLIS AVE 1-72	91402	6	192B149   190	2653019038	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.06	Electrical	Electrical	Apartment			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.22437	-118.45516	Plan check for the installation of emergency egress lighting and exit signs only. Project site is an existing apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58799	11041-10000-18622	453 E 95TH ST 1-10	90003	9	093A207    10	6052027022	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM	09/01/2011 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	33.95032	-118.26558	FIRE ALARM SYSTEM FOR A NEW BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58800	13041-20000-06508	1050 W 58TH ST PV-1	90037	9	108B197  1435	5002016018	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Expired	04/23/2015 12:00:00 AM	ADDRESS	33.98956	-118.2934	PV-1. Microinverter over the counter. 3.02kW combined.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58801	18041-10001-03812	14626 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM			PC Approved	08/03/2018 12:00:00 AM	ADDRESS	34.22128	-118.45073	DELTA 2 CHANGES TO APPROVED PLANS. REEVISED LIGHTING ABOVE PRODUCED AREA.T-24 ENERGY ONLY. PLAN CHECK ONLY. PERMIT# 18041-10000-03812<<<<<<<<FULL PC FOR POWER AND ENERGY FOR A NEW SHELL BUILDING. SCOPE INCLUDES A NEW 1200A 120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 23014 SQ. FT. B#18010-10000-00386>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58802	16041-30000-17655	513 E 32ND ST	90011	9	118-5A207 304	5120019025	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	10/01/2016 12:00:00 AM	ADDRESS	34.01769	-118.26562	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (13) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58803	14041-10000-10319	814 N CORONADO ST	90026	13	139-5A205 181	5402021011	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1957.10	Electrical	Electrical	Apartment			04/18/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.07699	-118.27037	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM USING SOLAR EDGE OPTIMIZERS FOR DUPLEX? TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58804	16041-10001-21580	100 WORLD WAY FOOD-COURT	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR T24 ENERGY ONLY FOR REVISED LIGHTING IN SEATING AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58805	18041-10000-42688	7161 N SEPULVEDA BLVD	91405	6	183B145    82	2222029017	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Info Complete	11/07/2018 12:00:00 AM	ADDRESS	34.20086	-118.46648	TI IN AN EXISTING MACDONALD's RESTAURANT. REPLACING EXISTING LIGHTS IN THE MAIN DINING AREA WITH LED LIGHTS AT THE SAME LOCATIONS CONNECTED TO EXISTING CIRCUITS. EMERGENCY LIGHTS ARE EXISTING TO REMAIN.  T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-35199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58806	18041-20000-04476	6430 N PLATT AVE	91307	12	180B093   746	2036024053	(Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.18768	-118.64249	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to a restaurant. Total lighting area = 6,284 sq. ft.Note: Building application has been generated under 18016-20000-01197.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58807	15041-10002-00392	6201 W HOLLYWOOD BLVD 110	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	CHANGES TO AN APPROVED SET, NOTE CHANGES ON DELTA 10. CHANGES INCLUDE DIFFERENT TYPE OF MANUFACTURE FOR FIXTURES, L4 AND L10. (((Full plan check for first time tennant assembly area as a gym.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58808	14041-10000-30406	723 S DODSON AVE	90732	15	015B193   504	7560002025	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	33.73727	-118.31204	Installation of 7.54 kW DC roof-mounted PV1 system. System consists of (29) 260 W panels and (1) 7600 W rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58809	18041-10000-30118	19936 W ARMINTA ST	91306	3	189B113   910	2106004006	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Expired	04/26/2024 12:00:00 AM	ADDRESS	34.21305	-118.56788	NEW 7200W (DC) ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOME WITH 20 AC PV MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58810	19041-10000-17470	6502 N VAN NUYS BLVD	91401	6	180B149   597	2237014006	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM			Reviewed by Supervisor	05/20/2019 12:00:00 AM	ADDRESS	34.18884	-118.44845	PV2. NEW ROOFTOP COMMERCIAL SOLAR SYSTEM CONSIST OF 168 MODULES (TRINA SOLAR 360), 2 CENTRAL INVERTERS ( SUNNY TRIPOWER 30KW EACH) AND ONE 75KVA TRANSFORMER. SYSTEM SIZE IS 60.48KWdc AND 60KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58811	15041-20000-01945	700 W 9TH ST TEMP	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Closed	09/17/2019 12:00:00 AM	ADDRESS	34.04579	-118.2618	TEMPORARY POWER FOR PHASE 2 CONSTRUCTION 1600 AMP DISTRIBUTION BOARD.  PLAN CHECK FOR POWER ONLY. NO CofO AT THIS POINT IN TIME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58812	15041-10000-41981	1000 W WILSHIRE BLVD 20th FLR	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.05085	-118.26078	T-24, LOBBY REMODEL IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING  ON THE 20TH FLOOR. TOTAL SQ. FT. 817.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58813	19041-20000-13205	10880 W WILSHIRE BLVD STE 1150	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.05885	-118.44283	T24 PLAN CHECK FOR TI TO EXISTING HIGH RISE COMMERCIAL LIGHTING AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2,645 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58814	13041-10001-32311	9110 N HADDON AVE	91352	6	195B165    27	2629014117	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.23473	-118.40063	Expedited RSES plan check per applicant request.(((PV1, Install 4.5 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 18 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58815	17041-20000-37021	820 S SHERBOURNE DR	90035	5	135B173  1011	4333024030	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			10/16/2017 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/17/2021 12:00:00 AM	ADDRESS	34.06237	-118.37917	New 4-story 6-unit apartment building.  600A 240/120V 1ph-3w and 300A 240/120V 3ph-4w services supplying building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58816	11041-20000-22247	6920-6930 N VAN NUYS BLVD	91405	6	183B149   499	2217009801	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	ADDRESS	34.19604	-118.44846	Plan check power and energy for new AT&T Data Center on first floor of existing building. Upgrade existing service for new equipment. Medium voltage.Request for Modification to separate Fire Alarm system filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58817	17041-10000-33953	1590 E INDUSTRIAL ST	90021	14	124-5A215  47	5164022008	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.03572	-118.23538	PC for power for new 800 A 277/480V service for existing shell building to be reused for future light manufacturing. Installing new service, 8 panels and 4 transformers. Reconnecting existing loads to panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58818	15041-10001-02429	9270 N KEWEN AVE	91352	6	198B165   143	2629013067	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM			PC Approved	03/20/2015 12:00:00 AM	ADDRESS	34.23823	-118.40142	NOTE: Plan check expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.8 kWac. System consists of (2) inverters and (35) modules. Main service panel is being upgraded to 225 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58819	19041-10000-11033	11053 W VENICE BLVD	90034	5	117B161  1032	4252008034	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	PIN	34.01442334	-118.41569711	PV1 SYSTEM SIZE IS 2.14 KWdc, 1.90 KWac CEC. SEVEN CANDIAN SOLAR MODULES (305 WATTS) WITH SEVEN ENPHASE IQ7 MICROIVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58820	17041-20000-37947	166 S ALVARADO ST	90057	13	135A205   127	5154006010	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Apartment			10/24/2017 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	34.06484	-118.27127	Plan check for power and energy. New 84-unit modular apartment building. Checking common areas and service/feeders only, modular dwelling units to be state approved. 2000A 120/208V 3ph 4w service. T24 area - 18,635sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58821	15041-10000-43528	12705 W BLUFF CREEK DR 1-6	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	33.97516	-118.41485	Full plan check for a new building under a single plan, located in the same job site of a Methane ZONE, consists of  (6) new stand alone buildings with (6) different addresses and application numbers; Each building is identical and has 4-story and 6 units supplied by a 600-Amp service;  All electrical work for the plan are identical to  reference electrical applicaton #15041-10000-27550 located at the same site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58822	16041-20002-37465	7855 N LINDLEY AVE	91335	12	189B125   558	2102017058	(T)R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM			PC Approved	02/15/2017 12:00:00 AM	ADDRESS	34.2134	-118.52751	2.15.2017 - Plan check for modifications to approved set. Reduce number of pv modules from 128 to 111. Add AC disconnect and performance meter.=======Plan check for the installation of a solar pv system, roof-mounted on a church building and school building. 36kW ungrounded system [3*12kW]. (128) pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58823	11041-10000-01873	5032 N EAGLE ROCK BLVD	90041	14	162A223   211	5686004031	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM			Corrections Issued	02/01/2011 12:00:00 AM	ADDRESS	34.13787	-118.21419	T.I.  Two story parking garage.  Electrical plan check for Title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58824	15041-20000-27092												Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM					N	N	Express Permit	06/10/2024 12:00:00 AM
58825	13041-20000-32813	13345 N CONSTABLE AVE	91344	12	225B133    70	2601014025	RS-1, RS-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.31272	-118.50599	"PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 15KW. 60 MODULES AND 2 INVERTERS"" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58826	16041-20000-21975	7939 N KEER DR	91335	12	189B125   370	2102015007	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/17/2016 12:00:00 AM	ADDRESS	34.21513	-118.53492	PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58827	15041-20002-14497	12775 W MILLENNIUM Bldn A-Ste 4135	90094	11	102B161  1175	4211033020		West Los Angeles				2756.02	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	33.97584	-118.4171	01/14/2016 Changes to an approved set of plans. Plan check is for Delta 4 only. Changes have been made to the feeder for Panel A. Note: Address has been changed under 15041-10001-14497*****Previous Work Description*****Plan check for power and energy. Project scope is a first time tenant. Work includes the installation of (1) 250-amp panel, (1) 125-amp panel, and associated loads. Total lighting area = 1,491 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58828	14041-10000-23617	10961 N OSO AVE	91311	12	210B113   122	2707032014	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.2696	-118.57635	PV1, INSTALL 5.32 KW DC ROOF-MOUNTED MICRO INVERTER SOLAR ARRAY ON A SINGLE FAMILY DWELLINGS, INTERCONNECT WITH MAIN SERVICE PANEL.(19) MICRO INVERTER: ENPHASE M250-60-2LL-52X(19) SOLARWORLD SW280 MONO MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58829	14041-20000-08986	7507 N SEDGEWICK CT	91304	12	186B089   158	2027038007	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.20881	-118.65154	PV1.  Install 9.5 kW roof-mounted PV system, interconnect with main service panel.  (2) transformerless inverters: Power-One PVI-3.6-OUTD-S-US-Z-A.  38 modules: Canadian Solar CS6P-250PX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58830	18041-10000-04389	5137 N FIGUEROA ST	90042	1	150A227   112	5468003020	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM			PC Info Complete	05/01/2018 12:00:00 AM	ADDRESS	34.10635	-118.19984	PC for T24 only for new lights in car wash and car wash accessory building. Installing new 400A service, panel, lights, receptacles and equipment. Total area is  1926sqft. B# 17010-10000-05015	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58831	18041-10001-22577	333 S HOPE ST 32ND FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Info Complete	10/10/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	DELTA CHANGES TO APPROVED PLANS FOR REMOVING FURNITURE LIGHTS FROM INDIVIDUAL OFFICES ON 32ND FLOOR.PLAN CHECK ONLY. ELECTRICAL PERMIT WAS ISSUED UNDER: 18041-10000-22577<<<Plan check for Power and Energy on (E) office. TI with new loads > 400A, total area: 22,907 sq.ft. 32nd floor. (B# 18016-10000-18244)>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58832	18041-10000-47881	3720 S FLOWER ST	90007	9	118-5A201 106	5037030022	USC-1B	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/19/2020 12:00:00 AM	ADDRESS	34.01728	-118.28125	Instaling a new 1200Amp Switchboard for future temporary mobile generator to an existing 1200 Amp switchboard. No New Load Added.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58833	13041-10000-29227	12101 W MARINE ST	90066	11	117B153   232	4248002020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.01938	-118.44192	PV1, ROOF-MOUNTED SOLAR INSTALLATION INTERCONNECTING WITH EXISTING 200A MAIN SERVICE. MICROINVERTER SYSTEM DONE ON  NON-STANDARD PLAN. SYSTEM SIZE IS 3.9KW DC AND 3.225KW AC, WITH 15 MODULES (LG; LEG260S1C-A3) AND 15 ENPHASE M215 MICROINVERTERS ( M215-60-2LL-S2x) .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58834	15041-20001-14393	1024 S BURNSIDE AVE	90019	4	132B181   778	5085009008	R1-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	34.05647	-118.35158	08/14/2015 Changes to an approved set of plans. Changes were made to the PV module layout.*****Previous Work Description*****Plan check for PV roof monted 3.8kWac system with 10 modules and 1 inverter(3.8kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58835	18041-30001-03558	1522 S ORANGE GROVE AVE	90019	10	129B177   953	5068026020	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.04874	-118.36605	delta 1 change to an approved set , change include adding 2 panel boards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58836	12041-10000-00016	10953 N SAN FERNANDO ROAD A-B	91331	7	210B157   840	2619014008	CM-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.26909	-118.42557	"New ""Commisary facility"" with 4 catering units.  New commercial building with 800A service, new circuits, and equipment.  Units A & B, (West Building).  < This permit is for the WEST Building. The Permit Number for the EAST Building is 12041-10000-00018>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58837	19041-10000-41708	713 W M ST	90744	15	033B205   219	7415008029	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	33.78883	-118.2711	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 13 MODULES (Q-CELL 285W) , 13 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.7KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58838	12041-10000-09837	831 W 37TH ST #100,#102-#200	90089	8	118-5A201  22	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM	05/18/2012 12:00:00 AM		Permit Finaled	07/30/2012 12:00:00 AM	ADDRESS	34.01971	-118.28749	Plan check T24 Energy/Emergency lighting for USC SLH Lecture Hall #100, #102, and #200.  ALL PANELS AND CIRCUITS ARE EXISTING.   REPLACING LIGHTS AND CONNECTING TO EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58839	14041-10000-12559	525 E ANAHEIM ST	90744	15	030B209     7	7423023006	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Issued	06/30/2014 12:00:00 AM	ADDRESS	33.78047	-118.25663	INSTALLING NEW 150HP WATER INJECTION PUMP. PLAN CHECK FOR HAZARDOUS LOCATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58840	16041-20001-45429	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.05048	-118.25755	10.18.2017 - Plan check for modifications to approved set. Add 16 fixture F7s in elevator lobby. Update floor plan and T24 documents to reflect changes. Changes clouded.======Plan check for energy only.  TI to lobby space of high rise building.  New lighting (incl. emergency) 9,260 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58841	16041-10000-45651	5135 W ADAMS BLVD	90016	10	123B177   884	5049009050	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.03265	-118.35318	Full Plan check for a new 3 story, 10 unit mix use building with subterrenean parking. New service rated at 800 amps 240/120V 3phase 4wire. Total area: 8410.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58842	19041-10000-22672	2001 S WESTWOOD BLVD	90025	5	129B153   995	4323003013	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	06/26/2020 12:00:00 AM		Permit Finaled	01/11/2021 12:00:00 AM	ADDRESS	34.04645	-118.43415	PC for T24 only, scope of work is adding lighting and circuits for a change of use (retail to barber shop). Total affected area is 1078 sqft.From building ((CHANGE OF USE. CONVERT PORTION OF (E) RETAIL SPACE TO BARBERSHOP. TENANT IMPROVEMENT, DEMOLISH EXITING SHORT WALL, NEW PARTITION WALL. NEW LAUNDRY, SERVICE COUNTER, AND FLOOR TILE.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58843	11041-10001-05617	7133 W HAWTHORN AVE	90046		147B181   345	5548008014	R3-1		Hollywood	Hollywood Hills West			Electrical	Electrical	Apartment			03/08/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.09988	-118.34596	NEW 3 STORY 19 UNITS APARTMENT BUILDING.((((( changes made to previously approved set 500 mcm condoctors, bus bar changed to wire 500 mcm.))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58844	19041-10000-37459	7687 N SAN FERNANDO ROAD	91505	2	186B177   564	2466036***	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.2083	-118.35573	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58845	11041-20001-02548	100 N WEST CHANNEL ROAD	90402	11	120B129   114	4410010021	[Q]C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM			PC Approved	03/03/2011 12:00:00 AM	ADDRESS	34.02831	-118.51901	PLAN CHECK ONLY FOR T24 ENERGY IN EXISTING RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58846	12041-20000-12374	7017 W SANTA MONICA BLVD	90038	4	144B181   441	5532016015	C2-1D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	ADDRESS	34.09084	-118.34222	ENERGY PLAN CHECK CHIN SAW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58847	15041-20000-38118	400 S HOPE ST SUITE 1050	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	T-24, PC FOR ENERGY ONLY. TI ON EXISTIN COMMERCIAL BUILDING (OFFICE/RECREATIONAL AREA). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AREA IS 2965 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58848	18041-10000-13030	11750 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Apartment			04/17/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Closed	01/31/2022 12:00:00 AM	ADDRESS	34.04843	-118.4618	NEW TEMP POWER FOR CONSTRUCTION OF A 34 STORY RESIDENTIAL HIGHRISE. 1600 AMP 277/480 SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58849	18041-10001-10626	2727 S KRIM DR	90064	5	126B165   597	4308015016	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.04119	-118.40004	EXPEDITE PER CUSTOMER REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58850	16041-20000-27464	4900 N SERRANIA AVE Dining	91364	3	169-5A109  71	2166046026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.15898	-118.58816	"Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 600-amps for Dining Building (""MSC""). No new load is being added onto subpanels."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58851	14041-10000-08704	3620 S MCCLINTOCK AVE PARTIAL-4TH FLOOR	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.0213	-118.28935	T24 FOR EXISTING OFFICE SPACE ON THE 4TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58852	13041-10000-35523	3769 N LIMESTONE PL	91403	4	162B149   386	2277031010	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/22/2014 12:00:00 AM	ADDRESS	34.13953	-118.45851	PV1, Install 9 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US and Solaredge SE5000A-US. (36) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58853	12041-10000-24536	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	INSTALLING TWO 500KW , TWO 330 KVA AND ONE 800 AMPS MANUAL SWITCH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58854	15041-20000-03454	12180 W MILLENNIUM 3RD FLR	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTS NEW CONTROLS AND NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN THE 3RD FLOOR.  TOTAL SQUARE FOOTAGE 18765.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58855	17041-10000-29886	1525 S LOS PALOS ST	90023	14	117A227    72	5192002016	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.01513	-118.19535	PC FOR OFFICE TI  WITH NEW RESTROOMS FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, CIRCUITS WITH LIGHTS RECEPTACLES AND EQUIPMIENT. TOTAL AFFECTED AREA 1080 SQ.FTB# 17016-10000-12548	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58856	18041-20000-18953	9200 N OAKDALE AVE 2nd Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is the 2nd floor of an existing high-rise building. Project scope is a tenant improvement. Total lighting area = 3,106 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58857	17041-10000-09769	9373 N SYLMAR AVE	91402	6	198B149   183	2644029900	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.24082	-118.44751	PC FOR ENERGY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING 21885 SQ. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58858	19041-10000-06350	1412 S ALAMEDA ST	90021	14	121-5A215 227	5166026004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			Corrections Issued	02/21/2019 12:00:00 AM	ADDRESS	34.025	-118.23905	full PC upgrade switch board to 600A ,120/240V, 3ph, 4w.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58859	16041-20000-21206	10347 W DIAMOND ST LOT 8	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58860	13041-10000-08166	111 E UNIVERSAL HOLLYWOOD DR 16TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58861	15041-10000-31040	10114 S COMPTON AVE	90002	15	091-5A213 215	6048013042	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	33.94476	-118.24606	T-24. PC FOR ENRGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (2 CLASSROOMS ADDED TO A CONVENT). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 1526 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58862	15041-10000-35035	611 N WESTERN AVE	90004	4	141B193   838	5522010019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1924.20	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Expired	11/16/2017 12:00:00 AM	ADDRESS	34.08203	-118.30929	Energy plan check for removing HID light fixture and replace with LED fixture in a commercial building, retail.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58863	16041-10001-31862	1800 W 11TH ST	90006	1	129A203   133	5136020026	C1-1-HPOZ	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Apartment			11/27/2018 12:00:00 AM			PC Approved	01/31/2019 12:00:00 AM	ADDRESS	34.04867	-118.27781	PLAN CHECK ONLY, PERMIT FEES PAID UNDER MASTER PERMITSUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS CHANGES INCLUDE CHANGING FEEDER FROM COPPER TO ALUMINIUM, VOLTAGE DROP, FUALT CURRENT, AND AMPACITY VALUES. Engineer of project has been changed per owner's request <<Full PC for a new 3 story 25 unit apartemtn building. 3 typical units. New serivce 1200A 120/208 3phase 4wire. Total sqft = 7007. Note *** Outdoor title 24, and green building complicance fees were not added on submittal fees.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58864	12041-10000-08102	16973 W STARDUST PL	91344	12	219B133   600	2609026037	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	05/11/2012 12:00:00 AM	ADDRESS	34.29395	-118.50175	9KW PHOTOVOLTAIC SYSTEM ROOF-MOUNTED  ON SFD;3 STRINGS EACH WITH 12 MODULES WITH 8KW  INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58865	17041-20000-02828	1025 S ABBOT KINNEY BLVD	90291	11	108B145   928	4239021026	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	33.99217	-118.47173	Plan check for energy only. TI to ground floor restaurant. New lighting (incl. emergency). 1,655sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58866	19041-10000-03681	12457 N GLADSTONE AVE STE G	91342	7	219B161   235	2525018059	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Issued	01/31/2019 12:00:00 AM	ADDRESS	34.29638	-118.41277	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58867	14041-10000-06033	2215 W FARGO ST	90039	13	145-5A209 236	5422016034	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.09235	-118.25928	PLANCHECK FOR POWER. UPGRADE THE ELECTRICAL SERVICE FROM 200A TO 600A 120/240V, 3PHASE 4 WIRE AND INSTALL 6 NEW AIR CONDITIONING UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58868	12041-10000-21844	633 W 5TH ST	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.05099	-118.25468	tenant improvement in offices on the  63rd floorplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58869	19041-20000-16107	20746 W BEECH CIR #311-pv1	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.29375	-118.58553	pv1install roof mounted pv system sized 3.02KW AC interconnected with msp.(9) acm at 335W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58870	17041-30000-19266	2323 S SEPULVEDA BLVD	90064	5	123B153    19	4322022007	M2-1VL	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.03739	-118.43584	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement/combining (3) existing tenant spaces into (1). Total lighting area = 7,102 sq. ft.Note: Building application has been generated under 17016-30000-11609	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58871	18041-20001-35137	12506 W SANFORD ST	90066	11	105B161   667	4221012028	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM			PC Approved	10/04/2018 12:00:00 AM	ADDRESS	33.98409	-118.41688	Expedite per applicant requestPlan check for PV roof mounted system, system size: 14.46kW DC with 49 modules and 2 inverters(6.0kW) connected to MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58872	15041-10000-39565	12411 W FIELDING CIR	90094	11	105B161  1220	4211034062	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM			PC Approved	11/23/2015 12:00:00 AM	ADDRESS	33.97968	-118.40871	"PROPOSED 1'-1"" X  6' -6"" S/F  LEDs ILLUM CANOPY  SIGN ""F""  LOCATED ATOP (E) LEDGE ""LEASING""PLAN CHKIS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58873	18041-20000-12493	22622 W VANOWEN ST	91307	12	180B097    33	2038020063	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.19355	-118.61959	Plan check for Title 24 only. Project site is an existing music room in a high school. Project scope is a tenant improvement. Total lighting area = 1,449 sq. ft.Note: Building application has been generated under 18016-20000-10525	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58874	12041-10000-23243	12347 W LANDALE ST	91604	2	165B165    53	2364014052	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.15227	-118.40268	PV1 - Roof mounted transformerless P.V. system (3.36KWdc).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58875	14041-20000-11791	14528 W SAN JOSE ST	91345	7	207B149   788	2648021013	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/19/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.26132	-118.44946	PV1Install roof-mounted solar array on SFD. System size: 5.25kW(1) SolarEdge #SE3800A-US-ZB-U transformerless inverter(21) Canadian Solar #CS6P-250PX pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58876	17041-10000-41798	417 N BONNIE BRAE ST	90026	13	136-5A207  37	5157024039	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	2084.02	Electrical	Electrical	Apartment			11/17/2017 12:00:00 AM	05/01/2018 12:00:00 AM		Issued	05/01/2018 12:00:00 AM	ADDRESS	34.06999	-118.26536	PV2, ROOF MOUNTED SOLAR SYSTEM TO AN (E) APARTMENT BLDG USING A CENTRAL INVERTER. (17) MODULES AND OPTIMIZERS AND (1)5KW INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58877	18041-10000-22799	6430 W SUNSET BLVD	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.09782	-118.32979	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES RENOVATION OF GROUND FLOOR LOBBY, INTERIOR RESTROOM, AND GROUND FLOOR AMENITY SPACES. NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2869	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58878	18041-20000-23671	8111 N MARCH AVE	91304	12	189B093    76	2020009020	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.2173	-118.64272	Installation of 8kW/16kWh energy storage system in SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58879	11041-20000-16322	11600 W WILSHIRE BLVD LL&4th cor	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.05034	-118.45947	Lower level, 4th floor corridor remodel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58880	10041-10000-01436	3130 N NORTH BROADWAY	90031	1	138A223    63	5208005025	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01, 1998.00	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	02/17/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.07359	-118.20809	RESUBMITTAL OF EXPIRED PLANS.  ORIGINAL PCIS #07041-20000-14713. TENANT IMPROVEMENT - AUTO SHOP BEING CONVERTED TO MARKET ADJACENT TO SERVICE STATION.  COMPLY WITH DEPARTMENT ORDER DATED 10/05/2009.  PERMIT WILL EXPIRE 30-DAYS FROM ISSUANCE DATE.  (INVESTIGATION FEE WAIVE PER INSP. JAMES SWAIN).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58881	11041-20000-19477	15903 W VENTURA BLVD	91436	5	168B141   590	2261021103	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM			PC Approved	10/06/2011 12:00:00 AM	ADDRESS	34.15607	-118.47954	PLAN CHECK T24 ENERGY/EMERGENCY FOR CHASE BANK TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58882	17041-20000-19445	2032 E MARENGO ST	90033	14	132A225   155	5201014023	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.05638	-118.20741	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to a medical office. OSHPD-3 project per applicant. Total lighting area = 4,497 sq. ft.Note: Building application has been generated under 17016-10000-11592	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58883	12041-10002-27961	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	CHANGES  THAT ARE MADE IN THE FIELD DURING CONSTRUCTION-NEW PANELBOARDS AND CIRCUITS FOR AUDIO SYSTEM; NEW PANELBOARDS AND TRANSFORMERS FOR FUTURE USE. THESE CHANGES WERE MADE TO SWITCHBOARDS USE-1 AND USE-2.create electrical rooms and idfrooms and remodel (e) scoreboard control room and levels 1,3,5,6,8, and score board rooms. NOTE THAT FEE WAS DETERMINED BY SUBMITTORSEPARATE APPLICATION FOR NEW SERVICES AND ASSOCIATED EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58884	11041-20000-19756	2121 S AVENUE OF THE STARS #3200	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/16/2011 12:00:00 AM			PC Approved	09/16/2011 12:00:00 AM	ADDRESS	34.05554	-118.41342	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TI CREDIT SUISSE #3200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58885	11041-10000-00814	5800 W ARBOR VITAE ST	90045	11	093B169    79	4125020014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			01/14/2011 12:00:00 AM	01/25/2011 12:00:00 AM		Permit Expired	02/20/2013 12:00:00 AM	ADDRESS	33.95249	-118.38336	title 24 and energy for a small TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58886	15041-20000-29159	2118 E 7TH PL	90021	14	124-5A217 344	5166003012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.0334	-118.22922	Full PC for Power and Energy. New Tenant, 3 story retail build: 1&2 fl are showrooms, 3rd fl is offices. existing 800 A service, 3 new panels.Total area: 18538 sq. ft. Fees per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58887	13041-10000-05477	20750 W VENTURA BLVD	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM			PC Approved	03/07/2013 12:00:00 AM	ADDRESS	34.16638	-118.58506	T24 for non-emergency lighting in corridor and lobby for 2-story office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58888	13041-20000-15143	13645 W RIVERSIDE DR	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.15777	-118.43065	INDOOR AND OUTDOOR T24 FOR NEW MAINTENANCE BUILDING FOR HIGH SCHOOL. TOTAL SCOPE OF WORK: 7575 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58889	16041-10000-09165	925 N LA BREA AVE	90046	5	144B181   708	5531016020	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.08803	-118.34436	FULL PC FOR POWER AND ENERGY. TI FOR A NEW DAY SPA ON THE GROUND FLOOR OF AN EXISTING MIXED USED COMMERCIAL BUILDING. SCOPE INCLUDEW NEW LIGHTING, TWO NEW 600A DISTRIBUTION BOARDS, AND SEVEN 225A SUBPANELS. TOTAL AFFECTED AREA IS 16,620 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58890	11041-10000-06850	818 W 7TH ST	90017	9	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	02/15/2012 12:00:00 AM	ADDRESS	34.04895	-118.25943	Ti for a flower shop. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58891	17041-20000-14222	9043 N WOODMAN AVE UNIT 1-3	91331	6	195B153   151	2639033013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Issued	06/14/2017 12:00:00 AM	ADDRESS	34.23394	-118.43971	PLANCHECK FOR POWER ONLY. NEW UNDERGROUND 2500 AMP SERVICE AND PANELBOARDS IN EACH UNIT. UNIT 1-3. MSB-2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58892	19041-30000-21522	10201 W PICO BLVD Bldg 89-2nd Floor	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.04994	-118.41129	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 293 sq. ft.Note: Building permit has been issued under 19016-30000-10143	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58893	19041-20000-44021	11441 W DONA EVITA DR	91604	2	159B169   730	2381007022	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	34.1283	-118.38119	PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 10.23 KW DC/9.765 KW AC. ESS SIZE IS 13.2 KWH. SCOPE OF WORK CONSISTS OF 31 PV MODULES WITH MICROINVERTERS A COMBINER BOX, A SUB PANEL, AND A 5 KW BATTERY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58894	18041-10000-41652	768 S SAN JULIAN ST	90014	14	126A211   215	5145008019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.03974	-118.24901	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58895	11041-20000-13071	360 N LA BREA AVE	90036	5	138B181   131	5525032027	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	ADDRESS	34.07788	-118.34383	Plan check for repair and reinstall existing 800A switchboard. No new loads. Existing service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58896	13041-10000-25878	8041 N GREENBUSH AVE	91402	6	189B157   233	2301008012	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.21708	-118.42684	PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 5KW. TRANSFORMERLESS INVERTER. 20 TSM 250 MODULES. 1 POWER ONE AURORA 3.6 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58897	17041-10000-18439												Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM					N	N	Express Permit	06/10/2024 12:00:00 AM
58898	14041-10000-14877	12658 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	33.97735	-118.41444	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58899	18041-20000-34139	4244 N COLOMA AVE	91364	3	165B097   344	2078018017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.14888	-118.62559	Plan check for a PV1 roof-mounted PV system. System size is 11.655 kWdc/11.4 kWac and consists of (1) inverter and (37) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58900	13041-10000-03306	2437 S CORINTH AVE	90064	11	123B153   403	4260038038	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			02/08/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.03379	-118.43917	REPLACEMENT OF FIRE ALARM PANEL AND ADDITION OF DEVICES TO THE SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58901	15041-20002-29390	9301 N SHOSHONE AVE	91325	12	198B129   214	2766020040	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM			Reviewed by Supervisor	09/14/2015 12:00:00 AM	ADDRESS	34.23982	-118.51791	PERMIT FEES $0.00 BY STATE SENATE BILL#1222Plan check for a PV1 roof-mounted PV system. System size is 21.2 kWac and consists of (2) inverters, (80) modules, (2) combiner boxes, and (1) load center.Permit Under 15041-20000-29390	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58902	15041-20000-30501	20649 W HORACE ST	91311	12	207B109    26	2707028018	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.26736	-118.58361	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58903	17041-10000-24797	2737 E WINTER ST	90033	14	129A227   101	5177019009	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.04859	-118.20027	PC FOR ROOF MOUNTED PV ON SFD. SYS. SIZE 3.8KW/AC14 MODULES WITH OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58904	18041-20000-39905	3187-3189 N GLENDALE BLVD	90039	13	154-5A207 219	5435026022	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	34.11782	-118.26148	Plan check for Title 24 only in existing space retail T.I. divide space in to two Total area: 1169 sq ft. B#18016-20000-18441EXISITING SERVICE (2 GANG)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58905	13041-10000-21526	10250 W SANTA MONICA BLVD PV2	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	PV2 Plan check for roof mounted canopy 214.20 KW photovoltaic system on top of parking structure.  Line side interconnection located at Westfield main building. Site located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58906	12041-10000-28397	217 S HOOVER ST	90004	13	136-5A201  55	5501019009	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			11/27/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	ADDRESS	34.06988	-118.28451	FIREALARM for 9 UNIT APT. 2 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58907	16041-20000-18644	3650 E OLYMPIC BLVD 4th floor	90023	14	118-5A227 227	5191024011	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	34.01861	-118.1992	Plan check for Title 24 only in existing space T.I. Total area: 20,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58908	15041-20000-10236	19119 W VICTORY BLVD BLDG 10	91335	3	180B121   530	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.18675	-118.54997	PV2. APARTMENT BUILDING. ( TWO MIRRORED BUILIDING ONE ADDRESS) (2 OF 2) BUILDING 10 , SYSTEM SIZE: 9.75 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58909	17041-20000-04462	16643 W SUPERIOR ST	91343	12	201B137   538	2686006016	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.24708	-118.49515	pv1install roof mounted pv system satndard plan sized 5kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58910	11041-10000-14257	1425 N SAN PABLO ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM	07/19/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.06176	-118.20365	adding luminaires to parking lot	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58911	13041-10000-10041	1340 S BRINKLEY AVE	90049	11	129B137   208	4407007012	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	PIN	34.05192705	-118.49618824	PV1 SINGLE FAMILY DWELLING; 1-STORY HOUSE. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 10.535 kW. CENTRAL INVERTER: FRONIUS IG PLUS 10.0-1. TOTAL MODULES: 44; TSM-245 PA05.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58912	19041-20000-45576	2476 N GLENDALE BLVD	90039	13	148-5A209 168	5440002003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.1022	-118.25908	Plan check for Title 24 energy only, new lighting and associate load. Total area: 1410 sq ft. B#19016-40000-37800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58913	18041-20001-36866	1187 N PIEDRA MORADA DR pv1	90272	11	135B117   111	4431032006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.06752	-118.55155	10/9/2018Changes to an approved set of plans.  changes to increase system size to 13.6KW AC interconnected with msp.(34) LG modules 350Watts(2) ginlong 9KW/4.6KW invertersthis is plan check only.((((pv1install roof mounted pv system sized 11.6KW AC interconnected with msp.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58914	17041-10000-36662	5253 N VINELAND AVE	91601	2	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Expired	01/16/2018 12:00:00 AM	ADDRESS	34.16641	-118.37064	PC FOR T.I. FOR (E) RETAIL FOR TITLE 24  ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.PERMIT FOR LIGHTS PULLED UNDER 17041-10000-16425B# 17016-10000-24756	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58915	17041-10001-36915	742 N ORANGE DR	90038	5	141B181   378	5524014004	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.08467	-118.34147	PC FOR CHANGES TO APPROVED SET.SCOPE INCLUDES TWO ADDITINOAL  ESS'S (TESLA POWERWALL 2 )WITH NEW PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58916	15041-10001-06516	6220 N TOPANGA CANYON BLVD BLDG E	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	(((7/9/2015- CHANGES MADE TO APPROVED SET. ADDING NOTE 21 TO ALL THE TENANT SPACES. CALCULATIONS TO BE REVERIFIED. ALL PERMIT FEES FOR REVISIONS ARE ON BUILDING A APPLICATION 15041-10001-06518)))NEW FIRE ALARM SYSTEM IN BUILDING E AS MAIN FIRE ALARM SYSTEM FOR BUILDINGS A,B,C,D ON WESTFIELD PLAZA. 127 DEVICES AND ONE FA PANEL.B# 13010-10000-02908.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58917	13041-20001-08276	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	08/28/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	Modification to approved set of plans.  Change to lighting only, NO Other changes.  PLAN CHECK ONLY for Energy.         <<<<Full plan check. Affected load is over 400A at 208V 3 phase. Low rise commercial. Microsoft. Fire Alarm Variance has been filed.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58918	13041-10000-17949	3117 S GREENFIELD AVE	90034	5	120B157   315	4251009011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.02691	-118.42306	PV1 2.45kw XFRMless. 2 STORY. nonSTD. ROOFMOUNT.  [ 1 INV: solaredge SE3000A-US] [ 10 MOD: TRINA TSM-245PC05} with optimizers]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58919	17041-10001-09268	2275 W BRUNA PL	90027	4	153B193   172	5588002037	RE11-1	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.11435	-118.30399	Plan check for roof mounted PV system consisting of 1 central inverter (SE10000A-US), with 35 panels and (P320) power optimizers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58920	11041-20000-03588	15445 W VENTURA BLVD	91403	5	168B145   769	2261039012	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/24/2011 12:00:00 AM	05/24/2011 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.15467	-118.47025	Upgrade service to 800 amp.  New switchboard, main breakers, and feeders.  No changes in subpanels, branch circuits, and lighting.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58921	15041-20000-43974	4220 W MONT CLAIR ST	90018	10	123B185   840	5051006016	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Apartment			12/30/2015 12:00:00 AM			PC Info Complete	06/29/2017 12:00:00 AM	ADDRESS	34.03164	-118.33221	Plan check for power and energy. Project site is a new 5-story mixed use building. Building is (1) level of underground parking, (1) level of commercial, and (4) levels of residential (46-units). Work includes a new 1200-amp service and associated loads. Area is a methane buffer zone. Total indoor lighting area = 10,596 sq. ft. and total outdoor lighting area = 1,976 sq. ft.Note: Building application has been submitted under 15016-10000-27056.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58922	16041-20000-38500	22846 W VENTURA BLVD	91364	3	171B097   539	2042005065	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			Corrections Issued	10/31/2016 12:00:00 AM	ADDRESS	34.16531	-118.62473	New accessory storage building - car wash.  Plan check for energy.  Building permit filed under 16010-20000-05014.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58923	18041-20001-00197	17217 W LORNE ST	91406	6	189B133   152	2204006021	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM			Re-Activate Permit	10/09/2018 12:00:00 AM	ADDRESS	34.21733	-118.50821	4/12/2018changes to an approved set of plans, changes noted delta 1.  changes to upsize feeder call-out 3.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58924	12041-10000-12419	12035 N DELANTE WAY	91344	12	216B125   376	2601072008	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.29095	-118.52714	Plan check for installation roof mounted 11.04KW photovolaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58925	17041-10000-42926	1084 S FAIRFAX AVE	90019	10	132B177   990	5086001041	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.05594	-118.36466	Energy plan check for commercial building T.I. Scope includes new lighting and (1) circuit. Total area is 1,515 SQ FT.  Permit fee is paid under application number # 17041-70000-41785.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58926	18041-20000-02895	11150 W OLYMPIC BLVD #920	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.03956	-118.43857	PLAN CHECK FOR TITLE 24 ONLY FOR (TENANT IMPROVEMENT OF EXIST. OFFICE SPACE AT SUITE 920). TOTAL AFFECTED AREA = 1638 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58927	14041-10001-01484	1404 N LUCILE AVE	90026	13	144A203   154	5427015012	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.08949	-118.27954	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{{PV1, INSTALL 14.49 KW DC ROOF-MOUNTED SOLAR ARRAY FOR A  TWO STORY HOUSE. INTERCONNECT WITH MAIN SERVICE PANEL.(7 )STRINGS(2) INVERTERS: SUN POWER SPR-6000M AND  SUNPOWER SPR-7501F-1 UNI (42) MODULES: SUNPOWER SPR-X21-34}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58928	13041-10000-15084	8535 W 3RD ST unit # 975	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.07363	-118.37737	Title 24 and emergency lighting for a medical office. high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58929	16041-30000-42694	633 W 5TH ST 63rd Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only. Project site is a portion of the 63rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,465 sq. ft.Note: Building application has been generated under 16016-10000-28824	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58930	17041-20001-34462	14335 W JOY DR	91331	6	198B149   659	2644027249	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24139	-118.44581	Revision to approved set.  Change to higher power module type and inverter rating increased to 3.8 kW AC. (((PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58931	19041-20000-30929	6160 N LAUREL CANYON BLVD Ste 130	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	07/01/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	Distribution, power, and lighting for first time tenant.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58932	14041-10000-21444	9074 N VAN NUYS BLVD	91402	6	198B149   582	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.23513	-118.45006	T.I. title 24 plan check at counter. Area = 1230 sq. ft. Existing medical office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58933	18041-20001-48475	13541 W DESMOND ST	91331	7	210B157    39	2523004043	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.27569	-118.42748	12/26/19CHANGES TO APPROVED SET DELTA 1 ONLY CHANGES TO ADD NEW LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58934	15041-10000-32311	3044 S DANALDA DR	90064	5	123B165   126	4316015011	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.03655	-118.40348	CHANGES TO AN APROVED SET OF PLANS.  RELOCATION OF SOLAR MODULES. THIS IS PLAN CHECK ONLY.MASTER APPLICATION UNDER 15041-10000-31385	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58935	18041-20004-04909	501 N SOTO ST	90033	14	129A225   101	5175009029	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Apartment			03/15/2019 12:00:00 AM			Reviewed by Supervisor	03/29/2019 12:00:00 AM	ADDRESS	34.04865	-118.20687	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET, REVEALING INTERCONNECTIONS 1-11, CHANGE FROM LOAD SIDE CONNECTION TO SUB PANEL CONNECTIONS AND INSTALLATION OF SHUNT TRIPS.*ORIGINAL*Plan check for a PV2 roof-mounted Pv system. System size is  11.4 kWac/15.0 kWdc and consists of (1) inverter and (50) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58936	15041-10000-12756	1278 S VELASCO ST	90023	14	118-5A225 171	5190019006	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.01925	-118.20506	PV1 INSTALLATION OF 4.32 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE  FAMILY HOUSE, TIE WITH THE MAIN SERVICE PANEL.(16)MODULES:(1) INVERTER:	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58937	10041-10000-05457	1929 S BELOIT AVE 1-63	90025	11	126B153   468	4261031002	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Public Safety Only			03/25/2010 12:00:00 AM	03/25/2010 12:00:00 AM		Permit Finaled	04/09/2011 12:00:00 AM	ADDRESS	34.04254	-118.44403	Fire alarm system for 3-stories, 63 units apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58938	19041-20001-13937	13108 W RATNER ST	91605	2	189B157   290	2304021007	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.21658	-118.4194	Revision to approved standard plans completed on PV e-permit system.  Revision to 60A PV backfeed breaker for MSP connection of 10 kW rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58939	13041-20001-17448	9301 N TAMPA AVE Space 92	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM			PC Approved	09/04/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	((CHANGES MADE TO APPROVED SET OF PLANS. ADDED CHANDELIER TO LIGHTING PLAN))T24 FOR RETAIL SPACE #92. TOTAL SQRFT: 3303. REMOVED FIXTURE 'F' FROM THE LIGHTING PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58940	19041-20000-44384	6160 N LAUREL CANYON BLVD STE 100	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	02/19/2020 12:00:00 AM		Permit Finaled	08/14/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	Distribution, power, and lighting for commercial tenant space.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58941	18041-10000-23495	777 S FIGUEROA ST STE 4200	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	Energy plan check for an office T.I located on the 42nd floor of a high rise building. Scope includes new lighting and equipment with a total Title-24 area of  4304-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58942	18041-20001-42790	11211 W MOORPARK ST	91602	2	165B173   209	2366002020	R1-1-RFA-RIO, R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM			PC Approved	11/28/2018 12:00:00 AM	ADDRESS	34.15051	-118.37582	Plan check for Title 24 only in existing space. Total area: 1768 sq ft. Plan check onlyB#16014-20000-03862	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58943	17041-20000-34489	15926 W HAMLIN ST	91406	6	180B141   834	2233014016	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Re-Activate Permit	11/05/2019 12:00:00 AM	ADDRESS	34.1876	-118.48031	Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.5kW ungrounded pv system. (16) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58944	09041-10001-18735	9961 W LIEBE DR	90210		156B153   251	4382019013	RE40-1-H		Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES		Electrical	Electrical	1 or 2 Family Dwelling			11/03/2011 12:00:00 AM			PC Info Complete	12/01/2011 12:00:00 AM	ADDRESS	34.1212	-118.43852	Install a new 130KW backup generator in an existing single family house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58945	17041-30000-43620	11845 W OLYMPIC BLVD #1110W	90064	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.03291	-118.45177	Plan check for Title 24 only. Project site is a suite on the 11th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,836 sq. ft.Note: Building permit has been issued under 17016-10000-21336	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58946	15041-10000-07435	1 WORLD WAY	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	33.94469	-118.39817	NEW MCC FOR AMERICAN AIRLINES.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58947	13041-10000-07301	5351 N BELLAIRE AVE	91607	5	171B161   124	2346021051	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.16811	-118.40964	PV1 - ROOF MOUNTED 16.08KW PHOTOVOLTAIC SYSTEM USING AURORA TRANSFORMERLESS INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58948	14041-20002-00623	9678 N NATICK AVE	91343	7	201B149   541	2650018030	RS-1	North Valley		North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.24593	-118.45386	(((EXPEDITE FEES)))PV1 LF TRANSFORMER 3 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 5.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58949	14041-20001-08886	4419 N BABCOCK AVE	91604	2	165B161   230	2362027038	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.15108	-118.40645	EXPEDITED PLAN CHECK PER APPLICANT REQUEST(((PV1Install 7kW roof mounted PV system, interconnect with main service panel.(1) Transformerless inverter - SolarEdge Se6000A with power optimizers.(28) Renesola JC250M-24/BB.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58950	11041-10000-12637	3737 S WATT WAY	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Issued	12/13/2011 12:00:00 AM	ADDRESS	34.01921	-118.28872	Replacing motor control center and up grade service to 1000 amps, and reconnecting existing motors to motor control centers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58951	13041-10000-15393	5716 S CRENSHAW BLVD	90043	8	108B185   717	5006009007	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	33.99028	-118.33046	CHANGE OF USE PERMIT FROM RESTAURANT TO RETAIL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58952	18041-10001-33498	10250 W SANTA MONICA BLVD #1985	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM			PC Info Complete	12/17/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	DELTA 6 and 7 CHANGES TO AN APPROVED SET. CHANGES INCLUDE NEW CIRCUITS AND RECEPTACLES TO EXISTING PANELS.  T-24 FULL CHECK. TOTAL EFFECTED AREA IS 3979 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58953	13041-10003-03981	2626 E 25TH ST	90058	14	117A219   147	5168023009	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM			PC Approved	04/06/2015 12:00:00 AM	ADDRESS	34.0152	-118.22477	revisions to permitted set of p[lans:see attached sheets outlining Delta 6 CHANGES(((((((REPLACEMENT OF 480V DISTRIBUTION SYSTEM. RATED AT 4000A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58954	17041-10001-21304	3000 W LEEWARD AVE	90005	1	132B197   364	5077018011	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.05857	-118.28933	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE RELOCATING UNIT PANELS ON THE ADA UNIT FLOOR PLANS. NOTE: PERMIT IS PULLED UNDER PCIS#17041-10000-21304	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58955	18041-30000-02092	2211 N FLORIAN PL	90210	5	150B157    19	4384027022	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM			Reviewed by Supervisor	03/22/2018 12:00:00 AM	ADDRESS	34.11129	-118.42321	Plan check for Single Family Dwelling New 2 story with basement with 800A Service 120/240 1-Phase, 3 Wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58956	19041-10000-29744	790 W BASIN ST STE 9	90731	15	021B197   107	7445002007	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	06/18/2020 12:00:00 AM	ADDRESS	33.75577	-118.2946	Full plan check for power energy for a first time occupancy/ per applicants request. Scope of work incldues a new panel and circuits  with an existing 400A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58957	17041-10001-27653	1336 N WATERLOO ST	90026	13	141A207   141	5424025009	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1956.00	Electrical	Electrical	Apartment			11/01/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.08145	-118.26507	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD CHANGES UNDER DELTA 3 ONLY!SCOPE INCLUDES ROOF CHANGE IN STRING ROOF LAYOUT. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER ORIGINAL. PC for rooftop solar for 6kW PV system with 23 modules and optimizers installed in multifamily housing.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58958	14041-10000-26245	843-845 N SEWARD ST	90038	4	141B185    46	5533024021	MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.08649	-118.33326	Plan check for energy only 2013  Standards.  Corrections issued for 9/23/2014. Approved 11/12/2014.  Renovation of existing 2566 sq. ft. office building (ground floor) and addition of 1690 sq. ft. (second floor). Indoor and outdoor lighting. BLDG#14014-10-04162. Changes on plans include added controls for outdoor and clarifying information on forms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58959	16041-10004-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 8. REMOVAL OF RADI COMS CIRCUIT FROM FLOOR PLAN. PROVIDED UPDATED PANEL SCHEDULE. CLOUDED BLUE NOTES FUTURE SUPPLEMENTAL, NO PC AT THIS TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58960	13041-10000-22294	23424 W COMMUNITY ST	91304	12	192B093   292	2005016023	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.2211	-118.63717	PV1 8.82KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 2) INV: SOLAREDGE SE3000A-US and SOLAREDGE SE6000A-US] [( 36) MOD: TRINA {TSM-245PC05.18} with optimizers]Inspector to verify loads used in load calculations match with panelboard in the field.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58961	12041-20001-07818	5757 N LANKERSHIM BLVD	91601	2	174B169   366	2338023009	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			04/23/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.17541	-118.3812	Changes to approved set under 12041-20000-07818TI. Change of use to restaurant. 200A new load. Plan check for energy and emergency lighting only. 1029 sqft. Single story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58962	14041-20001-32455	19501 W VINTAGE ST	91324	12	204B117   562	2726014015	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM			PC Approved	12/18/2014 12:00:00 AM	ADDRESS	34.25191	-118.55838	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 10 KW INTERCONNECTED WITH MAIN SERVICE PANEL. (34) SUNPOWER 327W MODULES(2) POWERONE PVI-5000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58963	13041-10000-35935	777 E 10TH ST STE #111	90021	14	124-5A211 244	5132002041	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.03437	-118.24974	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 538 SQ FT. TOTAL OF (3) UNITS WILL BE REPLACED. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58964	15041-10001-34083	6562 W HOLLYWOOD BLVD	90028	13	148-5A187 189	5547015017	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.10141	-118.33308	CHANGE TO APPROVED SET OF PLANS. CHANGE LIGHITNG TYPE. NO CHANGES MADE TO FLOOR PLANS. UPDATED FIXTURE SCHEDULE AND TITLE T24 CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58965	19041-10000-02812	709 W MANCHESTER AVE	90044	8	097-5A201 241	6032015042	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	ADDRESS	33.96022	-118.28577	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58966	15041-10000-14744	10989 W VENTURA BLVD RiteAid	91604	4	162B173   398	2366022022	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.01	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.14107	-118.36985	ALTERATIONS IN THE SALES/RETAIL AREA OF A RITE-AID STORE : NEW PANEL BOARDS;NEW LUMINIRES AND RECEPTACLE CKTSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58967	16041-10001-29852	300 S LA CIENEGA BLVD	90048	5	138B173   769	5511032053	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM			Corrections Issued	10/24/2016 12:00:00 AM	ADDRESS	34.07301	-118.37628	10/24/16Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding/removing lighing fixtures, adding receptacles, and revising title 24 calculations. Note: Original application is under PCIS#16041-10000-29852(((((((PC for energy only to exiting coffee bean shop. Interior remodel. Adding new lighting and power. Total sqft = 1313.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58968	10041-20000-00952	11701 N MASON AVE	91311	12	213B109     9	2701002016	OS-1XL, [T]RE-1, [T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	01/19/2010 12:00:00 AM		Permit Expired	07/26/2012 12:00:00 AM				Private street lighting for tract 50510ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58969	10041-10001-25452	634 W 34TH ST 1st floor	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	06/01/2011 12:00:00 AM	PIN	34.02192429	-118.28551249	MODIFICATIONS TO AN APPROVED SET OF PLANS.  RELOCATING AND REMOVING LIGHTING FIXTURES.  PLAN CHECK IS FOR ENERGY ONLY.  <<<<<T.I. to partial of 1st floor.  Install general/emergency lighting.  Plan check for energy only.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58970	14041-20000-19899	12831 W KAMLOOPS ST	91331	7	204B161   360	2623024010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.25509	-118.41206	PV1.  Install 4.4 kW rooftop-mounted, utility-interactive PV system.  Enphase M250 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58971	17041-20000-11918	1910 N BEL-AIR ROAD	90077	5	150A151   600	4370013021	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.10459	-118.45051	Plancheck only for power.  Addition to single family residence with 600 A service upgrade. Combo permit including electrical permit fees issued under 15014-30000-00572.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58972	13041-20000-02056	20969 W VENTURA BLVD	91367	3	171B109    73	2167001013	C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	PIN	34.16701214	-118.59032578	Change to lighting in the restroom only of an existing restaurant.  PLAN CHECK ONLY for Energy.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58973	15041-10001-26224	5439 N SUNNYSLOPE AVE	91401	4	174B157   981	2344007016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	34.16965	-118.42701	EXPEDITED PER CUSTOMER REQUEST. (((PV1 PC FOR ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY RESIDENCE. (2) INVERTERS: 12KW , (40) MODULES.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58974	15041-20002-39313	4530 W BRAZIL ST 1-5	90039	13	165B205    88	5593011034	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM			PC Approved	12/17/2015 12:00:00 AM	ADDRESS	34.14653	-118.27344	"12/17/15Changes to an approved set. Changes include reconfiguring pv module layout on roof only. (((""0$ permit fees due to senate bill 1222""Install a roof-mounted solar array on a commercial building. Interconnect with a 1600A MSP.System size: 140kW (7 - 20kW inverters). Ungrounded system. Using 700W power optimizers. Each optimizer has 2 pv modules connected to it. (484) 310W pv modules."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58975	16041-10000-42795	10126 W ANGELO VIEW DR	90210	5	144B153   178	4357014002	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.09408	-118.43467	NEW SFD. USING 600A SERVICE WITH (4) SUB-PANELS. THIS APPLICATION IS FOR POWER PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58976	19041-10000-37381	12551 W SATICOY ST SOUTH	91605	2	186B161   472	2305025028	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.2052	-118.40664	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58977	18041-20000-25833	2802 N CHADWICK CIR	90032	14	141A233   308	5217004034	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.07846	-118.17549	PV1.  Install 6.175 kW roof mounted grid tied PV system.  (19) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58978	14041-20002-18314	21308 W NASHVILLE ST	91311	12	210B105   187	2706032024	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM			PC Approved	08/21/2014 12:00:00 AM	ADDRESS	34.26892	-118.5959	Modification to approved set.  Change of AC disconnect nominal current rating from 100A to 60A.  $0 plan check fee is due to Senate Bill SB-1222. (((PV1.  Install roof-mounted solar array on SFD. System size: 10kW.(1) IG Plus Advanced 10.0-1 UNI transformered inverter(30) SunPower SPR-327NE-WHT-D pv modules)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58979	16041-10000-33078	360 E 2ND ST 1ST FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC FOR TITLE 24,  ENERGY ONLY.TOTAL AREA 2060 SQ.FTCOMMERCIAL BUILDING 1ST FLOORSCOPE INCLUDES NEW LIGHTING AND RECEPTACLES IN OFFICE RESTROOMS AND CORRIDOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58980	16041-10000-34161	10250 W SANTA MONICA BLVD # 1750	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""J.Crew"" Ste. 1750.  Install new panels and its circuits, lights and receptacles. Total effected area: 5,498 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58981	16041-10002-45090	1301 W 7TH ST	90017	1	130-5A205 108	5143013022	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			08/22/2019 12:00:00 AM			PC Info Complete	09/03/2019 12:00:00 AM	ADDRESS	34.05249	-118.26766	Changes to an approved set of plans, changes include the revision of load calculations, lighting layout and room change lay out. Note all changes under delta 27.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58982	14041-10001-12736	7551 S DUNBARTON AVE	90045	11	102B161   304	4110026001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	33.97128	-118.41031	EXPEDITED RSES PLAN CHECK PER APPPLICANT REQUEST.[[PV1, INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL,  WITH OTIMIZEERS AND TRANSFORMERLESS INVERTER.]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58983	15041-20000-08173	1901 W 3RD ST	90057	13	135A205   313	5154020026	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.06206	-118.27026	Plan check for the replacement of the main service switchboard, (34) 100 amp rated unit panels, and (1) 100-amp rated house panel. No work being done within the tenant spaces.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58984	16041-10000-01021	1016 S TOWNE AVE #112	90021	14	124-5A211 349	5132009***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.03362	-118.24986	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 696.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58985	14041-10000-11095	828 W WASHINGTON BLVD	90007	1	124-5A203  90	5124018010	[Q]C2-2-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	PIN	34.03592238	-118.2762107	Remove HID light fixtures and replace with new fluorescent fixtures. TOTAL AREA 4604 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58986	19041-20000-13879	3028 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58987	16041-20001-15603	8537 N KEOKUK AVE	91306	3	192B113   104	2781013014	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM			Reviewed by Supervisor	05/10/2016 12:00:00 AM	ADDRESS	34.22562	-118.57408	Expedite per applicant request{{{{{Plan check for PV roof mounted system  SFD. System size: 11.7kW with 49 modules and 49 micro-inverters Enphase}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58988	14041-10000-21717	3406 S BARRINGTON AVE	90066	11	117B153   769	4249010011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Expired	09/12/2016 12:00:00 AM	ADDRESS	34.01578	-118.43323	Install roof-mounted solar array, interconnect with main panel.  1 inverter 4150 watts. 15 modules. System size = 3.825kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58989	10041-20000-21641	15055 W OXNARD ST	91411	6	177B145   427	2242027024	M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/29/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Closed	09/25/2023 12:00:00 AM	ADDRESS	34.17956	-118.46092	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM EXISTING OFFICE/WAREHOUSE TO OFFICE/ASSEMBLY HALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
58990	19041-10000-52935	6425 W OLCOTT ST	91042	7	201B205   250	2570013020	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Closed	04/27/2022 12:00:00 AM	ADDRESS	34.24931	-118.27227	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER WITH POWER OPTIMIZERS. (1) 11.4 INVERTER AND (45) MODULES. TOTAL SYSTEM SIZE IS 11.4KWAC/14.4KWDC/12.2 KWAC CEC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
58991	14041-20000-17601	400 S HOPE ST 710 730750	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.05199	-118.25366	T.I. IN AN OFFICE BUILDING :( 7,760 S.F. ), PC for T24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58992	18041-10000-44214	501 E TERMINAL WAY	90731	15	018B205    80	7440027918	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Issued	12/03/2018 12:00:00 AM	ADDRESS	33.7422	-118.26534	PLAN CHECK FOR POWER ONLY FOR EV CHARGER INSTALL (2) 480V, 250 KVA AND EACH 300 AMPS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
58993	19041-20000-11630	5659 1/2 E HUNTINGTON DR NORT	90032	14	147A239   344	5309027026	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	05/15/2019 12:00:00 AM	PIN	34.0969759	-118.15687406	addition of (1) tesla ESS 5KW to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58994	18041-10000-12403	16641 W ROSCOE PL	91343	12	192B137   280	2689010012	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.22137	-118.49512	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURE AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58995	14041-20000-13348	7635 N POMELO DR	91304	12	186B093    82	2027001004	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.2091	-118.63882	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.96KW INTERCONNECTED WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS SE SE5000A(43) TRINA SOLAR MODULES TSM-PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
58996	12041-20002-09378	1947 N WESTRIDGE TER	90049	11	138B133   457	4492012020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	ADDRESS	34.07113	-118.5007	Change SPR 7000m to SPR 6000m inverter. rooftop system.  See previously approved set of plans.  Existing permit 12041-20000-09378.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58997	19041-10001-33405	8445 N MELBA AVE	91304	12	192B093    79	2005014006	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.22347	-118.63567	Change to an approved set by adding (2) more modules on the plan. Total (27) modules. Portion of permit fee is paid under 19041-90000-33405.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58998	11041-10000-14204	7407 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	07/14/2011 12:00:00 AM	PIN	33.94363002	-118.42513364	T.I.  Renovation of office space for a single story building.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
58999	15041-20001-24503	5901 W CENTER DR	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			11/03/2017 12:00:00 AM			PC Approved	05/24/2018 12:00:00 AM	ADDRESS	33.97509	-118.38703	11/03/2017 Changes to an approved set of plans.  Delta-3 revisions only.  Change of feeder details, relocation of some unit feeders to different distribution boards relative to previous approved set. *****Previous Work Description*****(N) 280 UNIT + 1 MODEL UNIT RENTAL APARTMENT BUILDING CONSITING OF 5 STORIES OF TYPE V CONSTRUCTION APARTMENTS, 2 STORIES OF CONCRETE CONSTRUCTION PARKING & COMMON USES ABOVE.  1 LEVEL OF SUBTERRANEAN PARKING.  4000 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.T-24 TO BE SUBMITTED NEXT WEEK 8/10/15.FIRE ALARM VARIANCE TO BE FILED AT A LATER TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59000	13041-10000-16779	857 N LA CIENEGA BLVD	90069	5	141B173    21	4337002047	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.08684	-118.37666	permit to be pulled at EPC counter only. pc for energy only. TI TO 2 STORY BACKBUILDING OF BARTON G RESTAURANT. combined plancheck and permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59001	19041-20001-13446	4520 N VAN NUYS BLVD	91403	4	168A151   188	2265013025	C2-1VL-RIO, P-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.15371	-118.4485	Revisions to approved plans.  Changes to lighting system.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59002	15041-10000-27285	21215 W BURBANK BLVD 6th Floor	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.17353	-118.59268	Full buiild-out, plan check for power and energy to a high rise commercial bldg. (BofA), first time tenant. Scope of work is being done on the 6th floor. Installing (3) new panels.  Total sqft= 8,238 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59003	13041-10000-31315	1895 N RISING GLEN ROAD	90069	4	150B169  1611	5562019018	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.10513	-118.3852	PLAN CHECK FOR POWER AND ENERGY( RESIDENTIAL) FOR SINGLE FAMILY DWELLING. SERVICE SIZE 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59004	17041-20000-25051	6115 W SUNSET BLVD	90028	13	147A189    24	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.09819	-118.32261	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59005	17041-20000-16009	14857 W TUBA ST	91345	7	204B149   249	2647001028	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2017 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.2564	-118.45653	PV1.  Install 2.475 kW roof mounted grid tied PV system.  Microinverter standard plan.  (11) modules with Enphase microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59006	15041-10000-23569	10850 W WILSHIRE BLVD 1ST FLOOR	90024	5	132B153   338	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.05923	-118.44139	PLAN CHECK FOR ENERGY ONLY FOR EXISTING HIGHRTISE OFFICE BUILDING. SCOPE OF WORK IS ON THE FIRST FLOORPERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59007	19041-30000-30916	1003 E 4TH PL 100	90013	14	127-5A217  55	5163018002	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.04219	-118.23383	ENERGY PC FOR  TENANT IMPROVEMENT  COMMERCIAL OFFICE SUITE 100. AREA OF SCOPE 2483SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59008	11041-20000-05100	14149 W BESSEMER ST	91401	6	177B153   709	2240023007	M2-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.18092	-118.44162	Plan check power and energy for existing commercial building with new 3000A service system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59009	18041-30000-21835	7855 N HASKELL AVE	91406	6	189B141   158	2206002037	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM			Permit Finaled	09/24/2021 12:00:00 AM	ADDRESS	34.21324	-118.47511	PC FOR NEW FIRE ALARM IN 3 STORY STORAGE FACILITY. SCOPE INCLUDES (1) fire alarm panel, (2) power supplies and (352) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59010	10041-10000-09215	8925 N GLENOAKS BLVD	91352	6	195B173   260	2408006036	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Finaled	11/15/2011 12:00:00 AM	ADDRESS	34.23074	-118.36767	New P.V. system to affordable housing building.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59011	13041-20000-23682	12746 W KLING ST	91604	2	168B161   626	2362022004	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.15569	-118.41113	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 16 KW AC USING 3 CENTRAL INVERTERS, TRANSFORMERLESS. NONSTANDARD PLAN. TOTAL OF 47 MODULES. SOLAR CAP IN EFFECT. NO FEES DUE ON FINAL FEE PERIOD FOR PERMIT ISSUANCE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59012	13041-20000-32152	1025 S SIERRA BONITA AVE PV1	90019	4	132B177   831	5085003016	R1-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.05673	-118.35637	PV rooftop system, ENPHASE M215.  Single family dwelling.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59013	16041-20001-08073	453 S KENMORE AVE	90020	10	135B197   753	5502013018	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Apartment			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.06567	-118.29698	5/2/2017changes to an approved set of plans.  changes include routing of service entrance conductors and rearrangement of electrical equipment inside the electrical room.changes noted delta 1.  this is plan check only.(((((NEW FIVE STORY APARTMENT BUILDING, 69 UNITS, ON TOP OF TWO AND ONE HALF LEVEL ABOVE GRADE PARKING STRUCTURE. 3000 MSA, 13 Typical units. Total area: 61,992sq.ft (indoor) + 3,027 sq.ft (outdoor). Building is on METHANE ZONE and No work is done underground inside the building.**Fire Alarm variance is filed together with this application.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59014	17041-10001-17203	5320 S VERMONT AVE	90037	9	108B197   552	5001005033	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	02/05/2024 12:00:00 AM	ADDRESS	33.99348	-118.29133	CHANGES TO AN APPROVED SET OF PLANS. ALL PLANS ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE REMOVING LIGHTING FIXTURES, REVISING TITLE 24 CALCULATIONS, REVISING PANEL SCHEDULES, AND SINGLE LINE DIAGRAM. B#17016-10000-12385	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59015	19041-20000-17193	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.24912	-118.34256	PLAN CHECK FOR ADDITION TO EXISTING SFD EXISTING ENERGY STORAGE SYSTEM. SCOPE OF WORK INCLUDES 1 NEW 13.5KWH TESLA POWERWALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59016	14041-10000-09183	7715 N BURNET AVE	91405	6	189B145   659	2209033057	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.21058	-118.46306	NEW FIRE ALARM SYSTEM FORCHANGES OF USE TO OFFICE SPACE. 49 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59017	13041-10000-17842	8036 W OKEAN TER	90046	4	156B173   316	5570019030	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	34.12415	-118.37248	PV1.  Install 7.00 kW roof-mounted PV system, interconnect into main service panel.  {28 modules: Canadian Solar CS6P-250M} {Microinverters: Enphase M215-60-2LL-52x}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59018	10041-30000-01088	3121 S LA CIENEGA BLVD 1.03	90016	10	123B173  1581	4205035009	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM			PC Approved	01/21/2010 12:00:00 AM	ADDRESS	34.02996	-118.37306	TI IN AN EXISTING OFFICE AREA IN A SINGLE STORY BUILDING (BLAKWELDER 1.03). PLAN CHECK  IS FOR TITLE  24 ENERGY CALCS AND EMERGENCY LIGHTS AND EXIT SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59019	16041-20000-07754	430 N SALTAIR AVE	90049	11	135B141    21	4402003009	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.07008	-118.47501	Plan check for power for remodel and addition of single family dwelling. New service - 600A 120/240V 1ph-3w	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59020	16041-20000-23965	951 W 45TH ST	90037	9	111B197   200	5018007022	RD3-1	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	PIN	34.00295052	-118.29019613	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59021	14041-20000-31452	19200 W LASSEN ST	91324	12	201B121   161	2762003026	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.24973	-118.55147	Changes from previously approved plans.  Down size PV system from 11.73KW to 7.6KW.  Note: Previous approved plans 14041-20000-12086	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59022	16041-10000-35259	14950 W HAMLIN ST	91411	6	180B145   612	2235018030	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.18846	-118.45928	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (36)MODULES-HANWHA Q-CELL. Q PLUS-G4 280(36)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE7600A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59023	10041-20000-22744	18665 W DEVONSHIRE ST	91326	12	204B121    71	2728028023	C2-1VL, QC2-1VL, QP-1VL	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	12/29/2010 12:00:00 AM	PIN	34.25808925	-118.53932955	PLAN CHECK T24 GENERAL LIGHTING ONLY. TI FOR DAY SPA. EXISTING CIRCUITS AND EXISTING EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59024	16041-10002-43145	5334 N ALHAMA DR	91364	3	171B105   311	2167024022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Issued	10/18/2017 12:00:00 AM	ADDRESS	34.1663	-118.59282	Change to approved set by adding (1) panel and new ckts on the floor plan; All changes under delta-2 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59025	13041-10000-18445	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008020	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Closed	07/11/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	TEMPORARY CONSTRUCTION POWER FOR THE CONSTRUCTION OF THE NEW GRAND WILSHIRE HOTEL AND 5-STORIES PODIUM BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59026	14041-20000-06649	15955 W ARMINTA ST	91406	6	189B141   107	2206007020	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.21399	-118.48108	T24 FOR SHELL BUILDING. INSTALLING LIGHTS AND RECEPTACLES ONLY. EQUIPMENT INSTALLATION REQUIRES FULL PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59027	18041-10000-40738	17101 W VOSE ST	91406	6	183B133   413	2227023020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.19859	-118.50576	PERMIT FEE IS $0.00 DUE TO AS1414PC FOR SFD PV SYSTEM (TESLA ROOF TILE)SCOPE INCLUDES ABOUT 2000 SQ.FT OF TILES (669 MODULDS), 3 INVERTERS, NEW SUB-PANELS AND LOAD CENTER WITH ESS UNDER SUPP. PERMIT. TOTAL SYSTEM SIZE  14.2 KWAC/ 15.9 KWDC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59028	18041-10000-10009	19514 W RINALDI ST	91326	12	210B117    32	2701004033	A1-1, OS-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.27444	-118.56	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59029	18041-20000-04971	12514 W MAGNOLIA BLVD	91607	2	171B165   531	2357006017	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM			Corrections Issued	02/09/2018 12:00:00 AM	ADDRESS	34.16464	-118.40584	PLAN CHECK FOR TITLE 24 ONLY FOR (CHANGE OF USE AND COMBINE (2) RETAIL SPACES INTO (1) BEAUTY SALON). TOTAL AFFECTED AREA = 2083 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59030	19041-10000-26985	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.09918	-118.32644	PC FOR INSTALL 12' X 25' S/F EXTERNALLY ILLUM. SUPERGRAPHIC SIGN TO THE NORTH SIDE OF (E) APARTMENT COMPLEX PER DIR-2014-2793-SPP-DI-M1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59031	19041-20000-32290	8408 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59032	18041-10000-42068	111 N HOPE ST	90012	14	133-5A211 168	5161003910	PF-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.05807	-118.24862	Power plan check for (2) new 5000Amp 3-phase 480/277v service serving future EV charger located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59033	10041-10001-20821	12500 N GLADSTONE AVE	91342	7	219B161   168	2525019062	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	05/31/2012 12:00:00 AM	ADDRESS	34.29734	-118.41327	MODIFICATION TO APPROVED SET OF PLANS <<<<<<<This is a lab for manufacturing wafers for micro chips.  hazardous area. (variance for a separate fire alarm system should be filed)>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59034	16041-20001-21244	10358 W DIAMOND ST LOT 20	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC in Progress	06/27/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59035	19041-20000-10846	1187 S CRENSHAW BLVD 1-8	90019	10	129B189   590	5082025002	R3-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Apartment			03/26/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	01/25/2021 12:00:00 AM	ADDRESS	34.05009	-118.32578	Plan check for power and energy  for 8 units multi-family building 3 story. Total area: 4570 sq ft. 8 typical units. B#15010-30000-04488	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59036	14041-20000-15471	19773 W BAHAMA ST	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			06/10/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.23353	-118.56412	Conversion of (E) warehouse space to motion picture/television tape editing office.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59037	14041-10000-07652	550 S MAPLETON DR	90024	5	138B157    56	4359013028	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.07442	-118.42882	PV1, INSTALL 11.112 KW DC ROOF-MOUNETED SOLAR ARRAY ON A TWO STORY HOMAE,  INTERCONNECT WITH MAIN SERVICE PANEL.APPLICANT SHOULD BRING THE FIRE DEPARTMENT APPROVED SET,. (1) TRANSFORMERLESS INVERTER : POWER-ONE AURORA PVI-3.0-OUTD-US(208) &(2) POWER-ONE AURORA PVI-3.6-OUTD-US(208)(34) MODULES; SUNPOWER E20/327 NE-WHT-D	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59038	14041-10000-11588	1753 N GLENDALE BLVD	90026	13	144A209   285	5423006033	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.08733	-118.25986	Service up grade from 2 separate 200 amps single and 3 phase over head to one 800 amps over head and4 new sub panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59039	13041-20000-21766	15206 W PARTHENIA ST	91343	6	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.2281	-118.46381	Plan check for energy only. No exam rooms in scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59040	16041-20002-33395	2159 E BAY ST	90021	14	123A217   424	5166001002	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	34.03156	-118.22794	05/04/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Location of service drop from LADWP has changed.Note: Work description has been corrected to reflect an 800-amp electrical service.*****Previous Work Description*****Plan check for power only. Replacing 1200A service equipment. New 800A service panel. New distribution is included under application #16041-20000-33390.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59041	16041-10000-22452	9251 3/4 N CEDROS AVE	91402	6	198B149   642	2651007***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.23864	-118.45384	PC FOR PV SYSTEM SFD. TOTAL OF 24 MODULES AND CENTRAL INVERTER 6KW. SYSTEM USING STANDARD PLAN. SYSTEM IS ROOFTOP SOLAR	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59042	14041-10000-19705	17200 W VENTURA BLVD #224 & 225	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.16035	-118.50769	Plan check for energy only. 2013 T24. BLDG#14016 10 14295 : TI TO (E) RESTAURANT. NO CHANGE OF USE. DEMO ALL INTERIOR PARTITIONS AND REPLACE WITH NEW PARTITIONS AND COUNTER AND KITCHEN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59043	16041-30000-20330	7108 N AMIGO AVE	91335	3	183B121   299	2126006015	(Q)RAS3-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.19961	-118.53846	NEW FIRE ALARM SYSTEM 95 DEVICES AND I FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59044	19041-20001-44779	9635 N HILLHAVEN AVE	91042	7	201A199   249	2563037041	RE15-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.24451	-118.29047	11-14-2019 Changes to an approved set of plan, changes included revised main circuit breaker to 175 A. All Changes has been clouded. Plan check only permit covered under master application.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59045	16041-10000-04766	727 E 33RD ST	90011	9	117A207    85	5120024017	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Expired	03/12/2018 12:00:00 AM	ADDRESS	34.0159	-118.26366	PV1, INSTALL NEW 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(23) MODULES:SILEVO TRIEX U290 BALCK    (2) INVETER: ABB PVI-3.0-OUTD-S-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59046	12041-20000-18565	12349 N GLADSTONE AVE	91342	7	219B161   293	2525017003	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	10/11/2012 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.29389	-118.41128	Change of occupancy from H2/H3 to F1 manufacturing.  Repaire existing damaged building as result of an explosion.  Install new 800A service, subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59047	18041-20001-06437	3139 N CHANDELLE ROAD	90046	4	156B177    37	5570023034	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM			PC Approved	03/02/2018 12:00:00 AM	ADDRESS	34.12757	-118.3647	fee expedited and storage systemPlan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.11.4kW unground pv system. (27) modules with P400 optimizers and (3) 14kwh Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59048	12041-10000-00068	759 N MANSFIELD AVE	90038	5	141B181   304	5524014018	R1-1	Central	Hollywood	Greater Wilshire		1919.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2012 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	ADDRESS	34.08508	-118.34073	Plan check for new 5.54KW roof mounted photovoltaic system. single family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59049	17041-10001-30024	3345 W WILSHIRE BLVD	90010	10	132B197    22	5502028020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.06193	-118.2963	[This is plan check only, permit is covered under master] Revision to approved plan. Only change the model# of the FACP and the type of smoke detector.<<PC FOR FA SYSTEM USING MAIN PANEL AND 625 DEVICES.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59050	15041-20000-10036			11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	PIN	33.97921419	-118.41007299	void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59051	10041-10000-15451	1300 E FACTORY PL Building-K	90013	14	126A215   235	5164008031	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	04/28/2011 12:00:00 AM	ADDRESS	34.03904	-118.23584	3 storty commercial building. Existing Service, new Panels and circuites. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59052	16041-10000-40566	20050 W VANOWEN ST Unit D-E	91306	3	180B113    57	2134013018	[Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM			PC Info Complete	11/16/2016 12:00:00 AM	ADDRESS	34.19354	-118.57037	Energy plan check for a fire damaged repair. Scope includes (2) units D and E located inside a commerical building. Total area is 2060 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59053	10041-10000-10995	1118-1128 N HIGHLAND AVE	90038	4	144B185   651	5532020008	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM			PC Info Complete	06/10/2010 12:00:00 AM	ADDRESS	34.09129	-118.3384	new retail store in existing buildingplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59054	14041-20000-20073	5116 N VARNA AVE	91423	4	171B157   763	2359002018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Expired	08/26/2016 12:00:00 AM	ADDRESS	34.16348	-118.42455	pv1install roof mounted pv system sized 6.48kw interconnected with msp.  (27) solar world sw275 modules(27) enphase m250 inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59055	17041-10000-40500	930 N ROSCOMARE ROAD	90077	5	144B145   250	4369006002	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.08741	-118.45997	NEW SINGLE FAMILY DWELLING WITH ATTACHED GARAGE, 600 A, 120/240V, 1PH, 3W SERVICE.*Note: This is plan check only, permit is covered under the Building Combo Permit for SFD, Permit# 16010-10000-03837	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59056	13041-10000-04426	6600 N TOPANGA CANYON BLVD # 78	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/21/2013 12:00:00 AM			PC Approved	02/27/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	TENANT IMPROVEMENT TO RETAIL TENANT SPACE #78  AT WESTFIELD TOPANGA: PLAN CHK IS FOR TITLE 24; PERMIT TO BE OBTAINED AT ELECTRICAL COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59057	17041-10000-31493	7220 W SUNSET BLVD	90046	4	147B181   672	5548019027	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM			PC Info Complete	09/05/2017 12:00:00 AM	ADDRESS	34.09782	-118.34785	PC for T24 only for restuarant TI. Installing new lights, receptacles, cirucits and equipment. Total area of 1476sqft. B# 17016-10000-09128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59058	19041-20000-51131	375 N LA CIENEGA BLVD	90048	5	138B173    80	4337012068	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Apartment			12/11/2019 12:00:00 AM			PC Info Complete	12/19/2019 12:00:00 AM	ADDRESS	34.07806	-118.37692	Installation of (35) EV chargers to existing EV charging system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59059	11041-10001-13138	1000-1014 S DOREEN PL BLDG 44	90291	11	111B145   665	4243003037	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.00038	-118.46076	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59060	12041-20000-30579	2350 N ALLESANDRO ST	90039	13	147A211   361	5443028037	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1873.00, 1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	02/12/2013 12:00:00 AM	ADDRESS	34.0958	-118.2533	Transformerless inverter. PV-1. Jennings Residence. 3.92kW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59061	15041-10001-38941	10250 W SANTA MONICA BLVD # 9022	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE RELOCATION OF FIXTURES AND CHANGE OF TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59062	17041-20001-39766	5307 N ALHAMA DR	91364	3	171B105   415	2167003028	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM			PC Approved	11/04/2017 12:00:00 AM	ADDRESS	34.16559	-118.59403	expeditepv1install roof mounted pv system sized 3.8kw interconnected with msp.this is system (1) of a two part system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59063	17041-20000-02471	16201 W GILMORE ST	91406	6	180B137   604	2233032031	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.18776	-118.48605	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (15) AC PV modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59064	14041-10000-32355	6256 N TOPANGA CANYON BLVD Building C-Building D	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.18496	-118.6049	Power plan check for new electrical equipment related to outdoor lighting systems for common area of Westfield Topanga outdoor mall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59065	10041-30000-12106	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	ADDRESS	34.07594	-118.35916	Installing lighting and receptacle in restroom. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59066	19041-20001-23737	107 N DELFERN DR	90077	5	141B157   130	4358005006	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	ADDRESS	34.08012	-118.42866	"09-23-2019 Changes to an approved set of plan, changes include update generator to 150KW and 600A  ATS to 600A distribution, relocate load ""GH4"" and ""Fountain"" panels  to gust house distribution. All changes has been clouded as delta 3. ********orginal PC#: 16041-20000-44903                                            16041-30001-44903"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59067	16041-10000-41463	1249 S CATALINA ST	90006	1	129B197  1023	5078031028	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.04766	-118.29492	FIRE DAMAGE CELING REPAIR. PROVIDING UP TO CODE LIGHTING SYSTEM. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59068	19041-10000-31832	15001 S FIGUEROA ST	90248	15	072B201    60	6120029009	MR1-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Closed	03/27/2024 12:00:00 AM	ADDRESS	33.89604	-118.28344	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59069	18041-10002-18140	7919 S CROYDON AVE	90045	11	099B165   707	4107005032	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	33.96609	-118.39262	** ESS**New rooftop solar system on SFD, (32) modules with (32) power optimizers, (1) 7.6 kW inverter, (1) 13.5 kWh ESS, (1) 200A load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59070	16041-20000-19818	530 S CATALINA ST	90020	10	135B197   887	5502022017	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	34.06453	-118.29524	PV2.  Install 25.84 kW DC roof-mounted PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59071	14041-10000-20606	2753 W WAVERLY DR BLDG. 1(C)	90039	4	151-5A207 233	5438025012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Apartment			07/31/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.10855	-118.26334	Power plan check for new 3 story 5 unit apartment with a new 400 A service.    This permit covers building #1 (C).note. this job is for building 1, 400 amp service ( E14LA02667).  Applicant filed refund for following job:  building 2(E14LA02668) and building 12 (E14LA02669). Plan for building 1 need to be modify for building 1 plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59072	17041-10000-45501	400 S WESTERN AVE #204	90020	10	135B193   439	5503014026	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.067	-118.30888	PC for T24 only for message shop TI. Installing new lights and receptacles. Total area is 1232sqft. B# 17016-10000-34817.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59073	14041-10000-08361	4677 W PICO BLVD	90019	10	129B185   921	5083027014	C4-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM			PC Approved	04/15/2014 12:00:00 AM	ADDRESS	34.0488	-118.3379	fees under inspection:permit to be pulled at EPC counter only. Plan check for energy only. emergency lighting.  1 storyBLDG# 14016 10 00539: Interior remodel and change of use from auto repair to office : new non-bearing partition wall to convert one office into two offices in the showroom area .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59074	18041-10000-46233	21040 W CALIFA ST	91367	3	174B105     8	2149002021	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	06/03/2019 12:00:00 AM		Issued	06/03/2019 12:00:00 AM	ADDRESS	34.17715	-118.59163	TI in an existing one stoy (Non-Medical) office building. Replacing existing lights with new LED Lights. Title 24 - Only. 8100 Sqr Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59075	14041-20000-34442	10945 N ETIWANDA AVE	91326	12	210B125   634	2715005069	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.26935	-118.53184	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.8KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59076	12041-10000-28467	9160 N SEPULVEDA BLVD	91343	7	198B145   317	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.00	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.23735	-118.46731	Tenant improvement and change of use from beauty salon to take-out restaurant, including interior, non-structural remodel. PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59077	18041-20000-26860	5808 W SUNSET BLVD 2ND FLOOR	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check for Title 24 only in existing space T.I. office 2nd Floor.  Total area: 2728 sq ft. B#18016-10000-20254	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59078	19041-20002-00479	1225 N EL CENTRO AVE	90038	13	144B189   270	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	34.09329	-118.32459	Revision to approved set.  Change of solar combiner panel ratings, (1) inverter changed from 11.4 kW to 7.6 kW rating, module stringing modified throughout.  Approval for clouded portions on SLD only. (((Plan check for a PV2 roof-mounted PV system. System size is 107.1 kWdc/79.8 kWac and consists of (7) inverters, (306) modules, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59079	12041-10000-30314	5871 W RODEO ROAD	90016	10	120B173   442	4205027013	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM	12/17/2012 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.02198	-118.3747	PLAN CHECK FOR FIRE ALARM. INSTALLATION OF FIRE ALARM FOR SPRINKLER SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59080	16041-20000-28364	161 S AVENUE 49	90042	1	148-5A227  54	5467012015	R3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.20	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	ADDRESS	34.10172	-118.20126	Plan check for energy.  TI in (E) single story school building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59081	17041-10000-03071	5858 N VAN NUYS BLVD	91401	4	174B149    49	2245004001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.17734	-118.44837	PC for outdoor tile 24. Removing HID fixtures and replacing them with New LED ones. Area: 33,475.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59082	19041-20000-50224	9131 N DARBY AVE	91325	12	198B125   257	2764013012	(T)(Q)R3-1	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	07/24/2020 12:00:00 AM		Permit Finaled	01/08/2021 12:00:00 AM	PIN	34.2360127	-118.53407302	$0 PERMIT FEE DUE TO SB1222 AND AB1414PV2 PLAN CEHCK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 64.8 KW DC/58.7 KW AC CEC. SCOPE OF WORK CONSISTS OF (160) PV MODULES WITH OPTIMIZERS, (1) 33.3 KW INVERTER, (1) 20 KW INVERTER, (1) SUB PANEL, AND A 75 KVA TRANSFORMER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59083	15041-10000-18890	12725 N DE FOE AVE	91342	7	219B149    28	2508021039	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.30106	-118.44661	PV1, ROOF MOUNTED SOLAR SYSTEM. TOTAL SIZE, 7.85 KW. (24) MODULES SUNPOWER 327(2) INVERTERS: SMA AMERICA SB3800TL-USSMA AMERICA SB3800TL-USZONING CLEARANCE CLEARED ON 15041-10001-18890	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59084	17041-10000-39828	4200 S FIGUEROA ST	90037	9	114A201   129	5019028027	C2-1VL	South Los Angeles	Southeast Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.00721	-118.28249	Replace Outdoor existing fixtures with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59085	16041-10001-39115	19943 W LEMARSH ST	91311	12	204B113   304	2726001013	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	11/14/2016 12:00:00 AM	ADDRESS	34.25555	-118.56837	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(31)MODULES-LG 320N1C-G4(31)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE7600A-USNote: Permit fees are paid under PCIS#16041-90000-39115	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59086	18041-20000-25013	11650 W PICO BLVD	90064	11	123B153   717	4260033033	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.03185	-118.4448	Initial TI and change of use from retail to office for mixed-use building tenant spaces.  Plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59087	10041-20000-13575	15233 W VENTURA BLVD #1020	91403	5	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.1538	-118.46502	energy plan check # 1020	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59088	12041-20000-29073	10850 W NATIONAL BLVD	90034	5	123B157  1152	4254008003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	PIN	34.02994066	-118.42137081	T.I. for an existing retail space.  Tenant will take over an adjacent (but separate) tenant space for storage.  Two separate addresses with two separate services.  Plan Check is for both 10840 and 10850 National Blvd.  This Permit is for 10850.  Permit for 10840 is on 13041-20000-02341.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59089	16041-20001-33577	12322 W COHASSET ST	91605	2	186B165   261	2307024***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM			PC Approved	10/04/2016 12:00:00 AM	ADDRESS	34.20654	-118.40137	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59090	16041-20000-41391	8141 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM			Reviewed by Supervisor	01/19/2017 12:00:00 AM	ADDRESS	34.21903	-118.44896	PLANCHECK FOR POWER AND ENERGY. CORE AND SHELL. RETAIL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59091	19041-10000-35109	218 E COLDEN AVE	90003	8	093A205   172	6052013033	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	33.9491	-118.27106	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59092	19041-10000-39199	5901 W CENTURY BLVD #1518	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	33.94572	-118.38685	TI INAN EXISTNG OFFICE AREA IN SUITE # 1518 ON THE 15TH FLOOR.INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-26402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59093	17041-20001-24792	16509 W BLACKHAWK ST	91344	12	204B137   168	2679023013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.25848	-118.49178	expeditepv1install roof mounted pv system 3.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59094	11041-10000-15960	3320 S CENTRAL AVE	90011	9	117A209   419	5114026***	(T)(Q)C2-1L	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Issued	08/24/2011 12:00:00 AM	ADDRESS	34.0131	-118.25635	T.I.  First time tenant.  Retail to occupy space on first floor of building.  Currently, space is core and shell.  Building is 5 stories high.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59095	17041-20001-30702	7048 N SEDAN AVE	91307	12	183B097   210	2026028033	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.1994	-118.62853	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.12.8kW ungrounded system. (40) 320W AC modules.Derating main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59096	18041-20002-18371	1070 S HOLT AVE 1-29	90035	5	132B173   618	4332025020	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM			PC Approved	12/06/2019 12:00:00 AM	ADDRESS	34.05732	-118.37817	12-06-2019 Changes to an approved set of plan, changes include reduce load for Garbage Disposal, Microwave, Bathroom Fan, HVAC equipment,  update service load calculation, unit panel, unit load calculation,  update service equipment to 1000A, 1000A feeder size. All Changes has been clouded as Delta C only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59097	14041-10000-19135	200 WORLD WAY TERM 2	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	CONVERTING ROOM  TO AN IT ROOM 1599PLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59098	14041-20002-20539	17183 W OSBORNE ST	91325	12	195B133    93	2690002017	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM			PC Approved	08/26/2014 12:00:00 AM	ADDRESS	34.23351	-118.50845	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012CHANGES TO APPROVED SET OF PLANS. RELOCATED ARRAY AND REDUCE NUMBER OF MODULES.  NOW 58 MODULES. PLAN CHECK FOR RELOCATION AND REDUCTION OF MODULES ONLY. NO PERMIT ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59099	16041-30000-01086	7035 N WHITAKER AVE	91406	6	183B137   179	2225016017	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	02/27/2016 12:00:00 AM	ADDRESS	34.1986	-118.49795	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (17) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59100	18041-10000-48442	642 E FLORENCE AVE	90001	9	102B205   838	6023001008	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.01	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	33.97458	-118.26355	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59101	18041-10001-34714	6553 N HASKELL AVE	91406	6	180B141   432	2233003060	RD1.5-1-RIO, [Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	Apartment			09/11/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.1902	-118.47516	Expedite per applicant request.(((PV2 18.kw AC roofmounted system with (64) modules, and (1) inverters interconncting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59102	16041-10000-29377	8334 S LINCOLN BLVD	90045	11	096B157   258	4113016019	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	33.96192	-118.42081	PC FOR SERVICE UPGRADE TO 800A. INSTALL 4 NEW PANELS FOR SHELL DESIGN. FUTURE TENANTS UNDER SEPARATE PERMITS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59103	16041-10000-00326	12100 W WILSHIRE BLVD #300	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM			PC Approved	01/06/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	T-24, TI TO A COMMERCIAL SPACE ON THE THIRD FLOOR, SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTACLES ON OFFICES AND RECEPTION LOBBY. EXISTING EMERGENCY LIGHTING.  TOTAL SQ. FT. 990. **INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT # 15041-40000-41743.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59104	13041-20000-19027	9350 N ETON AVE	91311	12	198B105    64	2746010016	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.24087	-118.59542	Change to lighting in an existing single story office building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy,  with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59105	17041-10001-12410	740 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A201 122	5019025023	C2-1, R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.01093	-118.28686	"DELTA ""9"" & ""10"" CHANGES TO APPROVED PLANS. NEW PANELS, NEW LOADS, MODIFY T-24, ETC.Building Permit: # 16010-10000-02038Sign Permits: 18048-20K-02064, 18048-10K-02936, 18048-10K-02667"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59106	16041-20002-29823	12700 W VENTURA BLVD 2ND FLR	91604	2	162B161    29	2384022049	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	ADDRESS	34.14449	-118.40998	10/06/2016 Changes to an approved set of plans. Changes have been made to the floor lighting layout.*****Previous Work Description*****SUPPLEMENTAL PERMIT FOR 45 KVA TRANSFORMER, 100 AMP SUB PANEL AND CIRCUITS.*****Previous Work Description*****TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG.  TOTAL SQUARE FOOTAGE 3308.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59107	12041-10000-15035	2200 W OLYMPIC BLVD	90006	1	130-5A201 159	5136014025	C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	11/27/2012 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.05198	-118.28133	"""Phase 2"" of a motel remodel with a tear-down and rebuild of a builiding.  Two new 200A panels, loads, circuits.  Full plan check for Power and Energy requested by applicant."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59108	14041-20002-33926	6344 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM			PC Approved	08/13/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	"08-13-2015 Plan check for change to approved set of plans. Changes include feeder size from 2 sets of (4) #600KCMIL, (1)#3/0 GRND in 3-1/2""C to 3 sets of (4) #250KCMIL, (1)#1/0 GRND in 3""C. Changes apply to delta 7 only. {{{{{TI TO A RETAIL COMMERCIAL SPACE  [ BASSETT WOODLAND HILLS FURNITURE STORE] TWO STORY (WESTFIELD) .  FIRST TIME TENANT. NEW PANELS, TRANSFORMERS, CIRCUITS, LIGHTING. PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 14,681.}}}}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59109	14041-10001-05710	1339 N AVENIDA DE CORTEZ	90272	11	138B117   338	4431005029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.07166	-118.56009	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(14) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59110	19041-20000-04336	333 S GRAND AVE 39th Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.05271	-118.25179	FULL PLAN CHECK FOR POWER AND ENERGY FOR OFFICE T.I. ON A HIGHRISE BUILDING. SCOPE OF WORK INCLUDES CIRCUITS EQUIPMENTS AND LIGHTING ON AN EXISTING 2500A DISTRIBUTION SYSTEM. TOTAL EFFECTED AREA 44985 SQFT NEW CONNECTED LOAD OVER 400AMPS.LD# 19016-10000-03202	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59111	10041-10001-05250	9200 N GLENOAKS BLVD	91352	6	198B173   111	2408001003	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM			PC Approved	01/28/2011 12:00:00 AM	ADDRESS	34.2363	-118.37296	Modifications to previously approved set of plans for a new installation for CNG facility.  Electrical driven compressor.  Site is in methane buffer zone.  Modification to previously approved set of plans.  Inspector please verify listing of equipment installed in hazardous classified areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59112	16041-20001-02147	14545 W VENTURA BLVD	91403	4	166-5A151  95	2265010004	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.15135	-118.45029	02-09-2016 Change to approved set of plans, Changes include removed 4 lighting fixtures(1x4 LED)and replace with  Recess LT LEDs and Pendent LT. Changes apply to delta 1 only(((((((TI to existing commercial building. Plan check for energy only. Adding new lighting (incl. emergency). Total sqft. 682.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59113	19041-10000-04020	16001 W WOODVALE ROAD	91436	5	165B141   249	2285015002	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Issued	02/07/2020 12:00:00 AM	ADDRESS	34.14896	-118.48162	PC FOR FULL HOUSE REMODEL. SCOPE OF WORK INCLUDES 600A PANEL UPGRADE, (2) 200A PANELS, (1) 125A PANEL, LIGHTS, OUTLETS, AND (4) 9.5 KVA COOLING UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59114	18041-10001-03003	8800 N OAK PARK AVE	91325	12	195B133   330	2690011013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM			PC Approved	04/18/2018 12:00:00 AM	ADDRESS	34.23036	-118.50536	PC FOR CHANGES TO APPROVED SET FO REFLECT FIELD INSTALLATION. REVISED ROUTING OF AC SIDE CONDUCTORS TO MSP  ON DETACHED GARAGE. INCLUDING TRENCHING FROM MAIN HOUSE.THIS IS PLAN  CHECK ONLY! PC for 11.52kW (AC) rooftop solar on SFD. Installing 36 AC modules (12.96kW(dc)) and one load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59115	11041-10000-09637	862 S MAIN ST	90014	14	127-5A209 294	5145015002	[Q]C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/11/2011 12:00:00 AM	ADDRESS	34.04148	-118.25466	TI, CHANGE TO LIGHTING IN CORE AND SHELL NEW 2-STORY COMMERCIAL BUILDING.  T-24 OTC PLAN CHECK ONLY.  INTERIOR LIGHTING ONLY - EXTERIOR LIGHTING NOT PART OF SCOPE.  <<<<<<<<<<<FUTURE TENANT IMPROVEMENT FOR LEASE SPACE MUST RETURN FOR T-24>>>>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59116	15041-20001-20075	17046 W COTTER PL	91436	5	162B133    91	2292010029	A2-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.14293	-118.50458	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 16.4 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59117	18041-10000-22778	3717 W 64TH ST	90043	8	105B185   986	4004034037	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	33.98188	-118.3383	NEW ROOF TOP SOLAR SYSTEM TO A MULTI UNIT RESIDENTIAL BLDG, PER APPLICANT. (18) MODULES AND  (1) 5.2KW INVERTER. TOTAL SYSTEM SIZE IS 5.2KWAC/5.49KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59118	19041-20000-12892	11820 N STEWARTON DR	91326	12	216B121   349	2872023019	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.28732	-118.53988	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 13.86KW DC/10KW AC. SCOPE OF WORK INCLUDES (42) PANASONIC 330W PV MODULES WITH SE P400 OPTIMIZERS, AND A SE10000H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59119	16041-20000-04736	8914 N ETIWANDA AVE	91325	12	195B125   371	2769012010	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.23244	-118.53158	PV1.  Install 6.8 kW roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59120	15041-20000-01653	21860 W BURBANK BLVD Suite #150	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.17198	-118.60379	Plan check for energy only. TI to office, new lighting (incl. emergency) and receptacles. 1,476sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59121	16041-20000-06525	"4151 W PROSPECT AVE BLDG ""N"""	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for power and energy. TI to existing commercial building (offices).  Adding new lighting. Work includes 1 new 600A board, 1 new 100A HVAC panel, and 3 HVAC units. Total sqft. 6,279.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59122	14041-10001-02691	1323 S VICTORIA AVE	90019	10	129B185  1117	5082015010	R2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.04714	-118.32877	Expedited RSES plan check per applicant request.{{PV1, Install 4.24 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U.(16) Modules: SUNIVA OPT265-60-4-1B0}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59123	19041-20000-47144	1859 W 25TH ST	90018	8	123B193   453	5058021017	RD1.5-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.03375	-118.30497	PV1. INSTALL 12.21 KW DC PV SYSTEM WITH (37) MODULES AND MICROINVERTERS (ENPHASE IQ7X-96-2).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59124	16041-10002-41964	6701 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	33.93211	-118.40783	PC FOR CHANGES TO APPROVED SET OF PLANS. INCREASED NUMBER OF LIGHTING FIXTURES IN HALLWAY AREA. PROVIDED UPDATE  FLOOR PLAN AND UPDATED T24 DOCUMENTS. PC ONLY PERMIT ALREADY COVERED UNDER MASTER APP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59125	14041-10000-16981	120 S ORLANDO AVE	90048	5	138B173   718	5511015019	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			06/24/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.07385	-118.37301	PLANCHECK FOR POWER AND ENERGY. NEW 35 UNIT ( 3 TYPICAL ) 4-STORY  APARTMENT BUILDING  OVER 1-STORY  PARKING GARAGE. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59126	13041-10001-27134	11613 W HAYNES ST	91606	2	180B169   686	2335005021	RD3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.18952	-118.38496	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 2.5 kW. TRANSFORMERLESS INVERTER. SOLAR EDGE POWER OPTOMIZERS.SOLAREDGE POWER OPTOMIZERS(10) TRINA SOLAR # TSM-250PA05.18(1) SOLAREDGE # SE3000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59127	13041-10000-31880	6019 S MANHATTAN PL	90047	8	105B193   661	6001017004	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	33.98451	-118.3096	BUILDINGTITLE 24 PART 6 ENERGY WORK FOR A 17900 SQ  FT FOR A RECYCLING FACILITY . SCOPE OF WORK IS FOR REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59128	18041-10000-25197	9301 N TAMPA AVE STE. 109	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK FOR TITLE 24 ONLY FOR - TI WORK FOR NEW TENANT IN EXISTING RETAIL SPACE. (N) NON BEARING WALLS, FINISHES, NEW FURNITURE AND FIXTURES - TOTAL AFFECTED AREA = 820 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59129	17041-10000-17549	3400 W 3RD ST	90020	13	135B197   211	5501024013	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	08/08/2017 12:00:00 AM	ADDRESS	34.06866	-118.28954	T24 ONLY. REPALCE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA OF LIGHTING:46000 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59130	18041-10000-15737	14056-14060 W BURBANK BLVD	91401	4	174B153   818	2247008031	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	07/24/2019 12:00:00 AM		Issued	07/24/2019 12:00:00 AM	ADDRESS	34.17195	-118.43963	PLAN CHECK FOR T24 ENERGY ONLY. REPLACING POWER AND LIGHITNG AT TWO  RESTAURANTS AND SALON DUE TO FIRE DAMAGE. NO NEW LOADS AND LESS THAN 400 AMPS PER APPLICANT.  14056: 868 SQFT, 14058: 901 SQFT, 14060: 900SQFTBUILDING PERMIT # 18016-10000-13196	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59131	17041-10000-12207	807 S MAPLE AVE	90014	14	126A211   101	5145012027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.04074	-118.25157	PC for energy only, Indoor Title-24. Remove HID and Install new LED fixtures. Area: 1000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59132	12041-10000-28746	725 S FIGUEROA ST #3005	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM			PC Approved	11/29/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	TI in office Bldg. EPC is for T24 & emergency lights. (30th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59133	18041-10000-40401	6181 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93246	-118.39332	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59134	14041-20000-19398	9236 N SHOSHONE AVE	91325	12	198B129   271	2766010011	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM			PC Approved	07/18/2014 12:00:00 AM	ADDRESS	34.23889	-118.51765	New roof mounted PV system with system size 8.4KW dc.  Note: Permit is under 14041-20000-17210	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59135	12041-10000-06062	4174 W PICO BLVD	90019	10	129B189   951	5072005025	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	06/13/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.04762	-118.32649	Plan check power and energy for exisitng public storage highrise building. New service, new lighting, panels, circuits,  elevators, and HVAC equipment. Modification to allow usage of unit equipment on existing high rise without emergency generator has been filed on 8/27/2009.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59136	16041-10002-11513	580 S ALAMEDA ST	90013	14	126A215   246	5164009001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.03894	-118.23818	RECHECKING PLANS FOR LOST SET. RESTAMP AS ORIGINAL. NO CHANGES UNDER THIS APPLICATION. PC ONLY. PERMIT STILL CONINUATION FROM MASTER PERMIT NUMBER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59137	10041-10001-09891	5050 N SEPULVEDA BLVD	91403	4	171A145   125	2263009024	R4-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM			Corrections Issued	10/13/2011 12:00:00 AM	ADDRESS	34.16224	-118.46592	MODIFICATION to previously approved plans.  New 3-phase 800A service, 800A panel, 3 additional inverters.<<<<Install a new 56KW (Total) PV system on an apartment building.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59138	17041-20000-28607	11111 W CUMPSTON ST	91601	2	174B173  1268	2350003061	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			08/14/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.17011	-118.37286	new 4 story 41 unit apartment building 1600 amp service.  plan check for power and energy.building permit number 14010-10000-03680	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59139	15041-20000-14738	15735 W ADDISON ST	91436	5	171B141   430	2261003014	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.16183	-118.47612	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (48) modules, (48) micro-inverters, and (1) 125-amp PV subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59140	18041-20000-25226	1406 W EAGLE VISTA DR	90041	14	162A227    44	5691012003	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Apartment			07/06/2018 12:00:00 AM			Reviewed by Supervisor	08/16/2018 12:00:00 AM	ADDRESS	34.14	-118.19461	Three new SFDs with common 600A 240/120V 1ph-3w service.  Plan check for power and energy.Building permits under:17010-10000-0374917010-10000-0375017010-10000-03751	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59141	12041-10001-00396	5519 N LAUREL CANYON BLVD	91607	2	174B165   858	2347015002	R3-1, [Q]C1.5-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	34.17066	-118.3967	Plan check for revision to approved plans. Changes to solar module type, relocate inverters location, and solar equipment. 39.520 KW (DC)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59142	16041-20000-29494	14721 W CALIFA ST	91411	4	177A149   147	2244009026	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.1777	-118.45431	1200 A 480Y/277V service upgrade to (E) single-story commercial building without current tenant.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59143	16041-20000-30985	18957 W CARMEL CREST DR	91356	3	162B121   162	2177048014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	06/24/2017 12:00:00 AM	ADDRESS	34.14115	-118.5437	PV1INSTALL ROOF MOUNTED PV SYSTEM WITH BATTERY BACK UP SIZED 7.6KW INTERCONNECTED WITH MSP.$10.37 permit fee is due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59144	10041-10000-19856	505 S FLOWER ST	90071	9	130-5A209 113	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.0515	-118.25654	TI IN AN EXISTING RESTAURANT. PLAN CHECK FOR T24 AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59145	19041-20001-37126	5528 N TAMPA AVE	91356	3	174B117   420	2163016013	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM			Reviewed by Supervisor	10/02/2019 12:00:00 AM	ADDRESS	34.17163	-118.55332	Expedited plan check feePV1.  Install 14.4 kW DC / 12.24 kW AC roof mounted grid tied PV system.  (45) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59146	14041-10000-11691	12360 W FOOTHILL PL	91342	7	213B165    45	2527022072	[Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1042.04	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	PIN	34.2841104	-118.40586813	""" $0 permit fee is due to the 2012 Senate Bill No. 1222"" PV2 154KWdc. 480V. negative GND. NONstd. 2story. Roofmount. [(2) inverters: {solectria pvi 75kw}]. [(616)modules: {Hanwha {HSL60P-PB-4-250TW}}]. not methanebldg#14016-10-08357:154.00 kW SOLAR ROOF MOUNTED SYSTEM ON TOP OF ROOF OF (E) 316' x 144' WAREHOUSE."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59147	13041-20001-24220	20362 W SCHOENBORN ST	91306	3	192B113   530	2781028035	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM			PC Approved	09/30/2013 12:00:00 AM	ADDRESS	34.22091	-118.57726	((expedite fees))pv1 single family dwelling. total system size 8kw ac using 36 modules. 2 central inverter nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59148	18041-10000-21048	1916 E 1ST ST	90033	14	129A221   284	5174016027	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.04613	-118.21695	PC FOR ROOF MOUNTED PV ON COMMERCIAL BUILDING. SCOPE INCLUDES 38 MODULES WITH 38 MICRO INVETERS. TOTAL SYSTEM SIZE 9.0KWDC  /9.12KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59149	13041-20000-14381	129 N SARATOGA ST	90033	14	127-5A225 312	5180016039	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.04233	-118.20446	"Change to lighting and loads in reading rooms of an existing Church.  No part of this scope is a ""Place of Assembly"" per the Engineer."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59150	16041-20000-25867	17955 W ARCHWOOD ST	91335	3	180B129   170	2122024034	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	PIN	34.19233362	-118.52439178	Plan check for PV roof mounted system. System size: 6.0kW with 26 modules and 1 inverter(6.0). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59151	16041-10000-30163	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.02201	-118.28947	New fire alarm installation for a new office commercial building. (1) Fire Alarm panel, (4) Communication panels, (4) Control panels, (610) Fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59152	10041-10003-20821	12500 N GLADSTONE AVE	91342	7	219B161   168	2525019062	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.29734	-118.41327	MODIFICATION TO APPROVED SET OF PLANS <<<<<<<This is a lab for manufacturing wafers for micro chips.  hazardous area. (variance for a separate fire alarm system should be filed)>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59153	17041-10001-20019	7864 N GAZETTE AVE	91306	3	189B109   645	2108028009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.21362	-118.58732	Expedite fees only.       Installation of new roof mounted solar PV system on existing single family dwelling.  Central inverter system with AC coupled battery back up.  Total system size = 5 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59154	17041-10000-10394	10201 W PICO BLVD 4th FL-BLDG 99	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Approved	03/31/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	Plan check for Title 24 only in existing building T.I. office space. Total area: 1378 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59155	12041-20001-15890	14006 W RIVERSIDE DR STE#: 111	91423	4	168B153   454	2269025***	(Q)C2-1L, (Q)PB-1L, C2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			Corrections Issued	09/11/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Modification to previously approved set of drawings.  Load is less than 400Amps.  PLAN CHECK ONLY FOR ENERGY, with Emergency lighting.                 <<<<<T.I. to existing building in the tenant space (Children Place).  Install general/emergency lighting with Tailor Method>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59156	19041-10000-32158	4331 N LOWELL AVE	91214	14	198B205     7	2572003079	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	PIN	34.23738151	-118.26686031	NEW 6.7KW ROOF MOUNTED PV SYSTEM WITH 21 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59157	18041-10000-02160	2501 W SUNSET BLVD C-D	90026	13	141A205   271	5402015026	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1956.00	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.07974	-118.26907	PC FOR Change of use from retail (existing tenant spaces C - D) to day care with one classroom.SCOPE INCLUDES NEW PANELS, EQUIPMENT CIRCUITS AND LIGHTS. TOTAL CONNECTE LOAD <400ATOTAL AFFECTED AREA 4142 SQ.FT .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59158	16041-20000-16886	4828 N DENNY AVE	91601	2	168B177   430	2421007012	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.15852	-118.36476	Plan check for PV roof mounted system. System size: 6.0kW with 26 modules and 1 inverter(6.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59159	17041-10000-16993	9408-9410 N OWENSMOUTH AVE	91311	12	198B105    66	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	PIN	34.2410613	-118.60115579	PC for power and energy for TI for electronic manufacturing facility in second floor of building. PC includes check for new 3000 A 277/480 service, new electronic manufacturing equipment, spray booth, outdoor compressor and power supply units for equipment. Total affected area is 15369 sqft.Bulding # 17016 20000 05741	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59160	18041-10000-19895	1721 N SYCAMORE AVE	90028	13	147B181   117	5548002003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Apartment			05/30/2018 12:00:00 AM			Reviewed by Supervisor	06/11/2018 12:00:00 AM	ADDRESS	34.10233	-118.34346	UPGRADE SERVICE TO 1200A FOR AN APARTMENT BUILDINGNO CHANGES TO EXISTING LOADS AT THIS TIME	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59161	18041-20002-07601	19314 W CHEYENNE ST	91326	12	207B117   223	2728004028	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.26472	-118.55376	06-12-2018 Changes to an approved set of plan. Changes include update inverter size: Solar edge SE 10000H-US(240V) Fees $0 Due to Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59162	15041-10000-29303	6250 N TOPANGA CANYON BLVD #1590	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	TI, PC for T-24 to a commercial bldg (nail salon). Scope of work: raplacement of light fixtures., new receptacles. sq ft = 1570NOTE: PER APPLICANT. THIS IS NOT A FIRST TIME TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59163	18041-30000-01534	10651 N BALBOA BLVD	91344	12	207B133   521	2695001013	(Q)C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.26381	-118.50253	Plan check for Title 24 only in existing restaurant new light indoor and outdoor. Total area: 1000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59164	13041-20002-05024	1800 N CAMINO PALMERO	90046	4	150B181   697	5572029013	RE9-1	Central	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.10368	-118.35012	Changes to approved set of plans. Addition of a 200A subpanel.Plan check for subpanel ONLY.PV1 SINGLE STORY ONE STORY HOME. TOTAL SYSTEM SIZE: 9.870 KW. TOTAL NUMBER OF MODELS: 42. [INVERTER: SUNNY BOY 8000-US-240] [SOLAR MODULE: ALEO. MODEL#: S79U235]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59165	10041-10000-07964	10343 N SEPULVEDA BLVD	91345	7	204B145   114	2649018001	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1097.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	09/27/2010 12:00:00 AM	ADDRESS	34.25877	-118.46768	Plan check T-24 Energy (general/emergency) lighting for office TI.  Existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59166	15041-20001-31569	1457 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM			PC Approved	02/08/2017 12:00:00 AM	ADDRESS	34.09731	-118.31598	02/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. There have been removal and relocation of electrical and mechanical equipment.*****Previous Work Description*****Plan check for power and energy. TI to existing  commercial building (5 floors). not a highrise per applicant.  Total sqft. 14,228.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59167	17041-10000-08417	1100 S HILL ST	90015	14	126A209   128	5139019034	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.03989	-118.25984	Plan check for new Fire alarm system mixed use building Highrise 7 Story 177 units for residential and retail spaces. Total alarm devices: 694 and 1 FACP. Note that building has building department modification for double podium construction on G051.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59168	11041-10000-20310	17001 W NORDHOFF ST	91325	12	198B133   605	2692019024	C2-1VL	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.23591	-118.50306	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59169	19041-10000-07248	333 S CHADBOURNE AVE	90049	11	129B137   269	4406024012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.05124	-118.49043	NEW ROOF MOUNTED PV SYSTEM WITH 729 PV TILES (TESLA SRT24) AND 3 CENTRAL INVERTERS(2 x DELTA SOLIVIA 5.2 & 1xDELTA SOLIVIA 3.8  )  ON A SINGLE FAMILY HOME. SYSTEM SIZE IS 17.3KWdc AND 14.2 KWac WITH 2 ENERGY STORAGE SYSTEMS (TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59170	16041-10000-04633	1522 W LOMITA BLVD	90710	15	036B193    60	7410002085	[Q]R3-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Apartment			03/02/2016 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	10/06/2021 12:00:00 AM	ADDRESS	33.79764	-118.30346	FULL PC FOR A NEW 2-STORY 14 UNITS APARTMENT BUILDING OVER 1 LEVEL PARKING GARAGE. NEW 120/240V 1 PHASE, 3 WIRE 800A SERVICE. TOTAL SQ. FT. 14329	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59171	17041-10000-02613	601 W ANAHEIM ST	90744	15	030B205   373	7416025036	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	33.7798	-118.26896	PC for title 24.  Remove exterior HID fixtures and replace with new LED fixtures. Area: 18,150 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59172	16041-20004-09655	712 S OLIVE ST Floors 1-7	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			Corrections Issued	01/09/2020 12:00:00 AM	ADDRESS	34.0462	-118.25568	Revisions to approved set.  Added series rated panelboards and relocation of loads to generator backup.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59173	15041-10000-09391	6111 S GRAMERCY PL	90047	8	105B189   843	6001012022	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	33.98411	-118.31358	PC FOR POWER AND ENERGY. TI TO 11 INDUSTRIAL UNITS. 11 MAIN PANELS WITH 11 SEPRATE PANELS FOR POWER AND ENERGY FOR EACH UNITS. TOTAL AREA 30270 SQ FT.CORE AND SHELL APP# 14041-10000-30292,  AND DESCRIBTION:<<<Power plan check for a 1600 Amp service equipment replacement,  plan also include installation of 2 new panels and a transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59174	18041-20000-05108	7440 W 81ST ST	90045	11	096B157    69	4114015007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	33.96281	-118.4279	installation of (1) tesla powerwall to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59175	12041-20000-23601	333 S HOPE ST	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	Change to lighting in the restroom of an existing high-rise office building on the 15th floor.  Plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59176	18041-10000-02525	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM			PC Info Complete	01/23/2018 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, PC for energy only. Scope includes new lights and receptacles for Terminal 6 kiosk and ticketing lobby remodeling for Alaska Airline at LAX. Total affected area is 9849 Sq. Ft . B#17016-10000-33814	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59177	15041-20005-43046	964 S BERENDO ST PHASE 2	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM			PC Info Complete	05/21/2018 12:00:00 AM	ADDRESS	34.05378	-118.29358	"05/21/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta O. Loads have been revised (added, removed, and revised). 12.28.2017 - Plan check for modifications to approved set. Adding 30kVA transformer and panel ""L2DA"". New circuits. 58 new circuits. Update floor plans, home-runs, and panel schedules. Changes clouded delta M and N.7/11/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA "" L "" CHANGES. REVISION OF LOADS AND ADDITION OF CIRCUITS IN THE PANELSCHEDULES FOR RECEPTACLES, TVS, SFD'S, WIFI AND PROJECTIONS SCREENS, MINOR CHANGES TO LIGHTING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59178	17041-20001-18658	8532 N HASKELL AVE	91343	12	192B141   155	2673011057	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.22566	-118.47624	expeditepv1install roof mounted pv system sized 5.2kw interconnected with msp with battery back up.AC coupled system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59179	12041-20001-07250	11639 W KLING ST	91602	2	168B169   672	2354017011	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM			Plans on Hold	05/31/2012 12:00:00 AM	ADDRESS	34.1559	-118.38687	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.customer applied for refund on 3/7/13 approved claim # 114183	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59180	16041-10000-00804	6600 N TOPANGA CANYON BLVD 1076	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RETAIL SPACE (SPACE 1076) WITHIN AN EXISTING MALL. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 2502 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59181	18041-20000-25190	8924 N BALCOM AVE	91325	12	195B129   182	2768028010	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Expired	05/05/2024 12:00:00 AM	ADDRESS	34.23306	-118.52118	Plan check for PV roof mounted system, system size: 11.4kW with 34 modules and 2 inverter(7.6kW and 3.8kW) connected to 200A Panel derated main breaker 175A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59182	16041-20001-21214	10341 W DIAMOND ST LOT 11	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59183	16041-20000-24690	1800 CENTURY PARK EAST 6th Floor	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	PIN	34.06270629	-118.4150769	Plan check for Title 24 only. Project site is the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,063 sq. ft.Note: Building permit has been pulled under 16016-20000-02370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59184	19041-20003-09551	7304 N JORDAN AVE	91303	3	186B105   848	2111013022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.20311	-118.60273	Revisions to approved plans.  Miscellaneous revisions to address as-built conditions.  $0 PLAN CHECK FEE DUE TO SB1222(((SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CHANGE TO SINGLE LINE, CHANGE SUB PANEL SIZE FROM 600A TO 225A)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59185	17041-10000-40317	5030 W ROSEWOOD AVE 1-22	90004	4	141B189  1101	5522021028	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Public Safety Only			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.07919	-118.31463	NEW FIRE WArning system for 22 units, 4-stories apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59186	15041-20002-23700	15760 W STRATHERN ST BLDG. 2	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.21559	-118.47701	[[5/23/16 CHANGES TO APPROVED SET. CHANGING THE PANEL TYPETO DISAGREGGATED PANEL INSTALLED , CHANGES TO T24 INDOOR AND OUTDOOR LIGHTING.]]]]Changes to approved set.  Changes affect building 2 only.  Changing location of subpanel.  Subpanel is changed from split bus to regular bus.  Lighting has been revised throughout.*****Previous Work Description*****          Plan check for power and energy.  Total area = 1,576 sq. ft. (indoor) + 100 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59187	11041-10000-17462	1627 N ECHO PARK AVE 1-7-bldg 4	90026	13	141A209    47	5419008036	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			08/17/2011 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.08235	-118.25475	NEW 7-UNIT APARTMENT BUILDING (BLDG 4). PLAN CHECK FOR ENERGY AND POWER. VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59188	17041-10000-41765	214 N LORENA ST	90063	14	126A229   108	5179019044	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.03849	-118.19399	Remove Outdoor HID fixtures and replace with new LED fixtures. T-24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59189	17041-10002-19990	5615 S MESMER AVE	90230	11	105B165   281	4220006076	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM			PC Approved	05/01/2019 12:00:00 AM	ADDRESS	33.98582	-118.40099	Changes to an approved set, scope of work includes adding new fixtures and reducing the quantity of existing fixtures indoor only. Affected area is 4222 SQFT.All changes are under delta 1((Energy plan check for a lost plan, new service and panels also being updated. Permit fee shall be paid under original application number with a total area of 5,771-SQ FT.       Building permit #15016-30000-02405))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59190	12041-10000-10360	8500 W BEVERLY BLVD #681	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	T. I. OF AN (E) RETAIL SPACE;  PLAN CHK IS FOR TITLE 24 AND 1 EM CKT  (Permit fees are under inspection.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59191	14041-20000-35474	735 S FIGUEROA ST #121	90017	14	129A207   336	4226001902	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	04/29/2015 12:00:00 AM		Issued	04/29/2015 12:00:00 AM	ADDRESS	34.04878	-118.26079	TI TO AN EXISTING COMMERCIAL SPACE.  ADDING NEW LIGHTING AND CONTROLS WITH NEW PANELS, CIRCUITS AND TRANSFORMER.  TOTAL SQUARE FOOTAGE 1325.  PLAN CHECK FOR  ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59192	17041-10000-33817	6840 N HAYVENHURST AVE	91406	6	183B137   405	2224019004	M1-1, P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Issued	09/21/2017 12:00:00 AM	ADDRESS	34.19484	-118.4922	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59193	19041-20000-40927	6159 N ATOLL AVE	91401	2	177B157   444	2331025021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.18278	-118.42047	PV1.  Install 13.2 kW DC / 11.4 kW AC roof mounted grid tied PV system.  (40) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59194	10041-20000-05057	11980 W SAN VICENTE BLVD # 906	90049	11	129B141   232	4265007052	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/19/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	ADDRESS	34.05208	-118.47215	DENTAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59195	13041-10001-04211	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			05/15/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	34.06209	-118.34912	PLAN CHECK FOR NEW APARTMENT BUILDING WITH LIVE/WORK UNITS. POWER AND ENERGY FOR NEW 175 UNIT APARTMENT. (SUBMITTAL 1 #13041-10000-04211) WAS INCOMPLETE. SUBMITTAL 2 #13041-10001-04211 TO COVER ALL ELECTRICAL WORK. (PETER WAS THE ORIGINAL PLAN CHECK SUBMITTAL 1) FEES FOR SUBMITTAL 2 CALCULATED UNDER SUBMITTAL 2. PERMIT TO BE ISSUED UNDER SUBMITTAL 1. (INSPECTION FEES) REFER TO PETER OR NABIL FOR QUESTIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59196	16041-10001-01002	1515 N AMELIA AVE	90731	15	024B193   527	7444006019	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/08/2016 12:00:00 AM	ADDRESS	33.75837	-118.30085	Supplemental per field revision on Online permit # 16041-90000-01002. (25) modules-Hanwha Q-Cells,   (1) inverter-Solaredge SE6000,    (25)optimizers-Solaredge SE-P300.Note: Clearance and permit paid under PCIS#16041-90000-01002.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59197	14041-10000-26450	18212 S WESTERN AVE	90248	15	063B193   242	6108001063	C1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	33.86511	-118.30893	Title 24 plan check. 2008 code. 1 story, restaurant, no change in occupancy. tenant improvment. 755 sp ft. emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59198	12041-20000-00050	4364-4366 N COLDWATER CANYON AVE	91604	2	165B161   379	2375007069	[Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Commercial			01/03/2012 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	34.15009	-118.41359	Existing commercial (restaurant) space.  Remodel of the existing light fixtures.  Load is less than 400 AMPs.  A permit has already been pulled for the job being done (11041-10000-25426).   Plan check is for energy and emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59199	13041-10000-19309	3680 W WILSHIRE BLVD #101	90010	10	132B193    65	5093006028	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	34.06149	-118.30603	13041-10000-19309Tenant improvement in an existing bankkPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59200	12041-10000-27266	1514 S MIDVALE AVE	90024	5	129B153    65	4324026003	R1-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.0532	-118.44107	NEW 4.16 KW ROOF MOUNTED PV SYSTEM FOR A SINGLE FAMILY USING ENPHASE 215	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59201	17041-10000-06697	12721 W SATICOY ST SOUTH	91605	2	186B161   470	2305026030	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.2059	-118.41013	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (INDOOR+OUTDOOR) TOTAL AREA 21500 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59202	18041-20000-07731	11111 W CUMPSTON ST	91601	2	174B173  1268	2350003061	R4-1L	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.17011	-118.37286	PLAN CHECK FOR FIRE ALARM PLAN CONSISTING OF 1 FIRE ALARM PANEL AND 129 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59203	15041-20000-16339	9919 S AVALON BLVD	90003	8	091-5A207  88	6052032045	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2406.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	33.9459	-118.26545	PC FOR T24 ENERGY ONLY. CHECK OUTDOOR T24 FOR NEW EXTERIOR LIGHITNG. NEW LIGHT IN STORAGE ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59204	19041-10000-15434	8704 S SEPULVEDA BLVD	90045	11	096B165   735	4123002010	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	33.95857	-118.39595	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59205	18041-20000-25578	18417 W BRYANT ST	91325	12	195B125   940	2786004007	P-1VL, [Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.22749	-118.53447	Plan check for power and energy. Project site is an existing tenant suite in a commercial building. Project scope is a change of use from office/shop to laboratory/tenant improvement. Work includes a 600-amp service and a total lighting area of 2,745 sq. ft.Note: Building application has been generated under 18016-20000-14655. Electrical permit fees have been paid for under 18041-20000-15869.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59206	19041-20000-52777	8340 W BIG CANYON DR	91040	7	210B189   300	2551019021	(T)(Q)RS-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.27168	-118.31489	Plan check for PV roof mounted system, PV system size: 11.34KW with 36 PV Modules and 1 inverter(10.0KW) and Energy Storage System size: 40.5KWh with 3 Energy Storage Devices(13.5KWh).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59207	15041-10000-06796	4362 S BROADWAY	90037	9	114A203   384	5111010032	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.00435	-118.27814	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59208	13041-10000-22751	4340 N CHAUMONT ROAD	91364	3	165B113   118	2174024021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.14968	-118.57542	PV1.  Install 7.50 kW DC roof-mounted solar array, interconnect into main service panel.  Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59209	16041-20000-15839	17647 W PRAIRIE ST	91325	12	198B129   194	2766001021	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.2396	-118.51952	Low permit fee is due to fee cap per State Senate Bill SB-1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 16.4KW INTERCONNECTED WITH MSP.(50) MODULES(2) SOLAREGDE INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59210	19041-30000-44180	2049 S CENTURY PARK EAST 1600	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24 PLAN CHECK FOR T-24 ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO TENANT. TOTAL SQ. FT. 23000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59211	18041-10000-23174	404 S FIGUEROA ST	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Issued	06/21/2018 12:00:00 AM	ADDRESS	34.05326	-118.25596	PC FOR CORRIDOR INSTALLATION OF NEW LIGHTS IN CORRIDOR IN A HIGH RISE FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA B#16016-10000-05158	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59212	14041-10001-09786	2641 S DELEVAN DR	90065	14	159A219   306	5684022007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.12921	-118.2259	(((EXPEDITE FEES)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59213	18041-20000-44128	21300 W VICTORY BLVD STE-400/470	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.18813	-118.59618	TI FOR AN OFFICE SPACE  IN A HIGH-RISE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL AFFECTED AREA IS 6163 SQ.FT. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59214	11041-10000-14652	1862 S LA CIENEGA BLVD	90035	10	126B173   416	5066005011	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			PC Approved	07/14/2011 12:00:00 AM	ADDRESS	34.04276	-118.3762	TI TO OFFICES OF AN EXISTING AUTO BODY SHOP.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59215	12041-20000-11238	550 S MAPLETON DR	90024	5	138B157    56	4359013028	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2012 12:00:00 AM			Corrections Issued	05/16/2012 12:00:00 AM	ADDRESS	34.07442	-118.42882	Changes to approved plan 11041-20000-26967	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59216	15041-10000-04596	554 S GRAND AVE	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	Title 24 plan check only.  Total area = 837 sq. ft.T.I. to existing retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59217	19041-20000-28507	19626 W VICTORY BLVD	91335	3	180B117   894	2132016017	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.18634	-118.56096	PV1.  Install 4.725 kW DC / 3.8 kW AC roof mounted grid tied PV system and 9.8 kWh energy storage system. (15) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59218	18041-10001-15507	881 N ALMA REAL DR #101 & 103	90272	11	126B125    97	4412009014	C2-1VL, P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	10/06/2020 12:00:00 AM	ADDRESS	34.04497	-118.52525	DELTA 004 CHANGES TO THE APPROVED PLANS FOR CHANGES TO THE FLOOR LAYOUT, ADDITIONAL CIRCUITS AND SPACE. SUPPL. BLDG PERMIT:  18016-10001-11723<<<<<PLAN CHECK FOR POWER AND ENERGY FOR TI - FOR COMMERCIAL MEDICAL OFFICE (PATIENT CARE AREA). WORK INLCUDES  COMBINE SUITE 101 & 103. NO CHANGE IN EXISTING USE OR OCCUPANCY. TOTAL AFFECTED AREA = 3455 SQ. FT. NEW ADDED LOAD IS APPROX. 100ABUILDING PERMIT # 18016-10000-11723>>>>>>>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59219	14041-10000-10403	2970 W OLYMPIC BLVD 103	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.05241	-118.29951	TI IN BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59220	13041-10000-29546	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.0346	-118.45665	NEW FIRE ALARM SYSTEM TO PROVIDE 24 HOUR SYSTEM MONITORING TO SPRINKLER SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59221	14041-10000-05695	620 N AVENUE 64	90042	14	154-5A233  32	5493022008	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.11941	-118.17842	PV1, INSTALL 1.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(6) MODULES: CANADIAN SOLAR CS6P-250PX(1)TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59222	17041-20000-29887	26326 S PRESIDENT AVE	90710	15	033B193   712	7411024034	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	33.78286	-118.30386	pv1install roof mounted pv system sized 2.5kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59223	16041-20000-15769	16030 W VENTURA BLVD #500	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Issued	06/16/2016 12:00:00 AM	ADDRESS	34.15598	-118.48247	Plan check for Title 24 only T.I. in existing office. Total area: 8,733 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59224	16041-10000-31265	500 S FIGUEROA ST	90071	14	130-5A209 117	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Info Complete	09/08/2016 12:00:00 AM	ADDRESS	34.05146	-118.25758	PC for T24 for TI in meeting room and printer room. Combined area of meeting and printer room is 247 sqft. installing new lights, receptacles and 5 new circuits. **750 sq. ft. of tenant improvement on the 3rd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59225	16041-10000-06476	8408-8410 W 3RD ST	90048	5	138B173   821	5511032045	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM			PC Info Complete	02/24/2016 12:00:00 AM	ADDRESS	34.07292	-118.37356	T24 ONLY. TI TO (E) RESTAURANT TO ADD NEW HANDICAP ELEVATOR TO ACCESS THE SECOND FLOOR. TOTAL AREA 3686 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59226	13041-20000-17089	8415 N RESEDA BLVD	91324	12	192B125   409	2785018063	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM			PC Approved	06/27/2013 12:00:00 AM	ADDRESS	34.22319	-118.53631	T24 PLAN CHECK FOR ENERGY ONLY FOR SINGLE STORY OFFICE BUILDING. TOTAL SQRFT 1226.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59227	18041-20000-24046	8425 N ZEILER AVE	91402	6	192B157   481	2637014057	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.22364	-118.42564	Plan check for PV roof mounted with battery back up system, system size: 7.6kW with 12 modules, 1 inverter(7.6kW) and LG Chem REU 10H.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59228	17041-20000-29048	864 S ROBERTSON BLVD	90035	5	132B169   100	4333015025	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM			PC Info Complete	08/16/2017 12:00:00 AM	ADDRESS	34.06106	-118.38339	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59229	11041-10000-01303	6733 N RESEDA BLVD	91335	3	180B125   101	2126034020	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM			PC Approved	05/25/2011 12:00:00 AM	ADDRESS	34.19301	-118.53623	T-24 lighting plan check for remodeled Taco Bell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59230	13041-10000-17640	200 E 1ST ST	90012	14	130-5A213  88	5161016020	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.05115	-118.24239	REMODELING OF OFFICE SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59231	12041-20000-03220	662 N SEPULVEDA BLVD	90049	5	138B145    76	4368016068	[Q]C2-1VLD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.07736	-118.4688	Roof mounted P.V. system (23.76 KWdc) for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59232	16041-10001-33241	380 WORLD WAY ROOM3N3-03	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Closed	08/22/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	01/09/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE MADE UNDER DELTA 1. CHANGES INCLUDE ADDING ONE NEW PANEL, NEW CIRCUITS, AND NEW LIGHTS FOR A NEW BREAK ROOM/MANAGER'S OFFICE/ AND STORAGE SHELVING. B#16016-10001-22298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59233	15041-20000-29069	1977 N COLDWATER CANYON DR	90210	4	150B161   104	4387022019	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Expired	09/28/2017 12:00:00 AM	ADDRESS	34.10728	-118.4057	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (38) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59234	19041-10000-22738	654 N VIRGIL AVE SUITE 101	90004	13	142-5A201 290	5539026035	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.08334	-118.28667	PC (Energy only) CHANGE OF USE FROM RETAIL TO RESTAURANT FROM SHELL.  TENANT IMPROVEMENT OF 1,716SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59235	18041-10000-04044	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	Full plan check for sign installation, load is greater than 400 Amp.  Scope includes adding new panelboards, new circuits, and new lighting. Total affected area is 3304 Sq. Ft. Reference application: 16041-10000-42999                                          B#16016-10000-27246	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59236	13041-20000-13167	1752 S SHENANDOAH ST	90035	5	129B169  1296	4303014009	R1-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/30/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.04673	-118.38272	Rooftop PV System for a new single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59237	11041-20000-20214	815 W COLORADO BLVD	90041	14	163-5A231 107	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	09/22/2011 12:00:00 AM	ADDRESS	34.14051	-118.18382	"T.I.  Adding new light fixtures to the ""specs suite"".  Plan check is for energy only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59238	17041-10000-00279	21201 W SHERMAN WAY	91303	3	183B105    69	2112023012	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.20121	-118.59446	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA (OUTDOOR) 17402 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59239	18041-10001-05899	3303 N NORTH BROADWAY FLR 2, 3	90031	1	138A225    15	5208012021	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.07394	-118.20626	Change to an approved set by modifying the lighting plan. All changes under delta-2 only.(((PC for power and energy for medical office building TI. Installing new panels, lights, receptacles and equipment. Total 39235sqft. B# 18016-10000-04041.OFFICE INTERIOR TI: INTERIOR PARTITIONS AND CEILING BUILD OUT  40,980 SQ FT OF SPACE (2ND AND 3RD FLOORS) )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59240	12041-10000-15792	8062 W WOODROW WILSON DR	90046	4	156B173   400	5570030015	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.123	-118.37406	New ground mounted photovoltaic system for an existing single family residence.  (Not in a methane zone)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59241	19041-20000-41378	11861 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	09/26/2021 12:00:00 AM	ADDRESS	34.28583	-118.38972	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59242	17041-10000-24380	4820 N BALBOA BLVD STE 110	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	PC FOR RESTAURANT TI. PC FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA IS 2200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59243	17041-10000-02610	5580 W THORNBURN ST	90045	11	102B173   297	4103005038	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.97409	-118.378	PC for title 24. Outdoor. Remove HID fixtures and replace with new LED fixtures. Area: 94,320.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59244	13041-10000-32601	8525 N TOBIAS AVE	91402	6	192B149   116	2653017051	(T)[Q]R4-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Apartment			11/20/2013 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.22563	-118.45185	Final fee is $0.00 due to senate bill for solar installations.PV2, ROOF-MOUNTED SOLAR INSTALLATION FOR APARTMENT BUILDING. SYSTEM SIZE IS 174.9 KW. FEEDING INTO 3 DIFFERENT METERS. (22) COMBINER BOX, (2) SUBPANELS, (19) INVERTERS, (3) SERVICES @ 600A ( 120/240 3ph 4w), 600A(120/240 1ph 3w), 400A (120/240 1ph 3w).(714) Modules: EcoSolargy ECO245A156P-60(19) Inverters: (1) Solectria PVI-50kW-240,  (18) KACO blueplanet 6400xiNOTE TO PLAN CHECKER: 714 MODULES WAS NOT CHARGED UNDER SUBMITAL, AND WILL BE CHARGED ON SUBMITTAL 2; EXPEDITED FEE WAS ADJUSTED TO REFLECT THIS CHANGE TO ACCOUNT FOR THE NEW FEE. BUILDING PERMIT UNDER: 13016-10000-24139APN #2653-017-051	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59245	16041-10000-09769	801 S FIGUEROA ST 18TH FLR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Expired	04/20/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	T-24, T.I  IN  (E) CORRIDOR ON THE 18TH FLOOR, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1545.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59246	13041-20000-34018	7951 W SUNSET BLVD	90046	4	147B177   995	5551017032	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.09821	-118.36302	PC FOR T24 ENERGY ONLY. NEW LIGHITNG EXISTING CAR WASH. TOTAL AREA 1739 SQ FT. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59247	16041-10001-01451	800 S FIGUEROA ST 9TH FLR	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM			PC Approved	03/02/2016 12:00:00 AM	ADDRESS	34.04771	-118.26116	03/02/16Changes to an approved set of plans. All changes are made under delta 1. Changes include removing/replacing lighting fixtures in the lobby area. ((((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 9TH FLOOR. SCOPE INCLUDES NEW LIGHTING FOR CORRIDORS, AND RESTROOMS ON THE 9TH FLOOR. TOTAL AFFECTED AREA IS 1348 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59248	19041-20000-04712	9007 N WOODMAN AVE Unit A	91331	6	195B153   291	2639033006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.23306	-118.43913	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,010 sq. ft.Note: Building permit has been issued under 18016-20000-19771	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59249	14041-10000-02662	3666 S 6TH AVE	90018	10	120B189  1598	5044028015	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.02094	-118.32345	PV1, Install 3.75 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel. Ungrounded system with power optimizers.(1) Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U.(15) Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59250	16041-20000-15153	4415 N FIRMAMENT AVE	91436	5	165B141   148	2283002024	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.1512	-118.47236	PV1.  Install 5.7 kW rooftop mounted PV system.  (19) modules with (1) 5kW rated central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59251	11041-20000-27622	20552 W KINGSBURY ST	91311	12	207B109   441	2707012037	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2011 12:00:00 AM	03/19/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.26335	-118.58152	8 KW Roof mounted photovoltaic system, SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59252	13041-20000-32067	1011 S GRETNA GREEN WAY	90049	11	129B145  1020	4264023010	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.04606	-118.46981	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING 33 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 4 STRINGS. 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59253	13041-20000-29086	9145 N DEERING AVE	91311	12	198B105   159	2746010030	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.237	-118.59622	Change to lighting and receptacles in an existing single story office building.  FULL PLAN CHECK for Power and Energy requested by the applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59254	15041-20001-20244	5 N LATIMER ROAD	90402	11	126B129   770	4409029004	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.03873	-118.5137	Expedite per applicant request[[[[[Plan check for PV roof mounted system. System size: 12kW with 40 microinverters and 2 inverter(5.0kW and 7.7kW).]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59255	13041-10000-27216	5555 E VALLEY BLVD BLDG #301	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.07489	-118.16218	TITLE-24 PART 6 ENERGY PLAN CHECK.Provide lighting fixtures and 2 outlets to warehouse building.  Title 24 plan check only for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59256	15041-10000-16413	11818 W WILSHIRE BLVD UNIT 300-PHASE 1	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Issued	09/29/2015 12:00:00 AM	ADDRESS	34.0474	-118.46308	PHASE 1:REMODEL OF THE CURRENT TENANTS IN VIRTO FERTILIZATION (IVF) LAB AND ADJACENT AREA IN MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59257	15041-20000-01407	11550 N INDIAN HILLS ROAD SUITE 380	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.27998	-118.45874	TI TO AN EXISTING MEDICAL OFFICE.  PLAN CHECK FOR POWER AND ENERGY.  SCOPE OF WORK TO BE PERFORMED IN SUITE 380.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59258	13041-10000-19356	5857 S CENTRAL AVE #100	90001	9	108B209  1518	6007003902	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	PLAN CHECK FOR POWER AND ENERGY FOR NEW STARBUCKS (SUITE #100). FIRST TIME TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59259	17041-30000-23333	11847 W KIOWA AVE	90049	11	129B145   639	4265015251	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.04896	-118.46545	Plan check for a fire alarm system for a 4-story, 29-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (112) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59260	14041-10001-33803	1170 S ALVIRA ST	90035	5	132B173  1097	5087014014	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	04/30/2015 12:00:00 AM	ADDRESS	34.05486	-118.37207	Expedite per applicant request.  PV1.  Install 7.395 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59261	12041-10001-03794	7311 N FIGUEROA ST Building A	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	12/02/2013 12:00:00 AM	ADDRESS	34.13623	-118.18853	CHANGES TO APPROVED SET OF PLANS UNDER PC # 12041-10000-03784. DELTA 4 CHANGES ONLY ARE CLOUDED. CHANGES INCLUDE OUTDOOR LIGHTING OF BUILDING A AND CHANGES OF THE INTERIOR OF BUILDING A TO CORE AND SHELL. ORIGINAL SET OF PLANS WILL BE DROPPED OFF. SQFT CHARGED UNDER BUILDING B CHANGES ( 12041-10001-03784)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59262	14041-10000-04954	1756 S WASHINGTON WAY	90291	11	106-5A147  30	4228003015	RD1.5-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	33.9876	-118.46267	PV1, INSTALL 6.095 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE6000A-US-ZB-U(17) MODULES: SUNIVA OPT265-60-4-1B0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59263	19041-20000-28222	16633 W VENTURA BLVD ste 540	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	34.15823	-118.49571	ti to an existing commercial building (high rise) adding ne lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59264	14041-10001-27933	7909 W ROSEWOOD AVE	90048	5	141B177  1153	5527020009	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM			PC Approved	10/20/2014 12:00:00 AM	ADDRESS	34.08022	-118.36192	Modifications to approved set.  As-built plan check to address inspection comments.  (((Title 24 plan check only.  Total area = 1272 sq. ft.T.I. to existing retail space.  New lighting and recepticles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59265	17041-10001-19729	865 S FIGUEROA ST 2700	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	OFFICE TI. NEW LIGHTING IN BREAK ROOM. PC FOR T24 ENERGY ONLY. PERMIT ALREADY ISSUED UNDER MASTER APPLICATION. THIS IS PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59266	15041-20000-06097	14906 W GILMORE ST	91411	6	180B149   769	2235021051	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.1874	-118.45782	Plan check for PV roof top mounted with 6.0kW with 3 strings and 29 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59267	16041-10000-04111	6306 N TUJUNGA AVE	91606	2	177B173   100	2336015007	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Expired	03/07/2018 12:00:00 AM	ADDRESS	34.18514	-118.37888	PV1 rooftop solar 4.1kW system using micro inverters. (19) HiS-S260RG(19) M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59268	18041-20000-44592	2337 N HIGH OAK DR	90068	4	153B193   292	5587003021	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	12/24/2018 12:00:00 AM	ADDRESS	34.11299	-118.31207	addition of (2) tesla powerwalls to an existing pv system.  plan check for power.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59269	14041-10000-28441	533 W 5TH ST 69 & 70	90731	15	015B197   205	7451028039	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	33.73956	-118.28867	PLANCHECK FOR  ENERGY ONLY. TENANT IMPROVEMENT FOR US BANK BUILDING. PLANCHECK PER APPLICANTS REQUEST. LEVEL 69 AND 70 .(((notified by email. phone number may be wrong)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59270	16041-20001-04870	7066 N MIDDLESBURY RIDGE CIR	91307	12	183B089   215	2028042014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM			PC Approved	02/22/2016 12:00:00 AM	ADDRESS	34.19922	-118.6482	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Addition of a 3 kWac system onto an existing 5 kWac for a total system size of 8 kWac. Addition consists of (1) inverter and (8) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59271	16041-10003-03575	5939 N TOPEKA DR	91356	3	177B121   726	2156014007	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM			PC Approved	03/22/2016 12:00:00 AM	ADDRESS	34.17832	-118.54628	***change to approved set: change on rooftop module orientation. No new equipment. Fee zero dollar per California Senate Bill 1222 Permit under #16041-10000-03575PV1. INSTALL 14.72 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(45) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTERS: SMA SB7700TL & SB5000TL-US-22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59272	19041-10000-05676	4604 S WESTERN AVE	90062	8	111B193   525	5016014003	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Apartment			02/15/2019 12:00:00 AM	01/21/2021 12:00:00 AM		Issued	01/21/2021 12:00:00 AM	ADDRESS	34.00167	-118.30875	INSTALL NEW 1600A 120/240V 3 PHASE 4 WIRE DELTA SERVICE. INSTALL NEW DISTRIBUTION BOARDS, PANEL, LOADS AND LIGHTING. Building Permit: 18010-10000-00801	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59273	17041-30000-25503	801 S FIGUEROA ST 3rd Floor-Restrooms	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site are the restrooms on the 3rd floor of an existing commercial building. Project scope is new lighting system. Total lighting area = 650 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59274	17041-10000-28021	609 N DILLON ST	90026	13	141A203   393	5401014013	C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.03	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/04/2020 12:00:00 AM		Permit Finaled	08/15/2022 12:00:00 AM	ADDRESS	34.07876	-118.27905	PC for power and energy for new multi-use building (Includes 52 unit apartment and retail). PC for new 120/208V 4000A service, new switchboard and distribution equip, panels, circuits and equipment. Building has two levels of subterranean parking, 1 level of commercial and two upper levels of residential. Total indoor of 62574 sqft and outdoor of 21370 sqft. Building#15010-10000-04188. Building is located in methane zone. Note that retail panels are not part of scope, only conduit will be put it in.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59275	19041-10000-39923	12600 N SAN FERNANDO ROAD 112	91342	7	219B149   173	2506034***	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.2988	-118.4577	Plan check for a STANDARD PV1 5kw AC / 6.08KW DC roofmounted system. Scope includes (1) inverter, (19) modules and optimizers interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59276	17041-10000-09376	1342 W ADAMS BLVD	90007	8	123B197   898	5055006012	R4-1L-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.03251	-118.29008	Plan check for Fire alarm system Charter School. with  125 devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59277	17041-20000-34779	17326 W BULLOCK ST	91316	5	177B133    64	2254032014	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/07/2017 12:00:00 AM	ADDRESS	34.17956	-118.51089	PV1.  Install 6.9 kW roof mounted grid tied PV system.  (30) modules with microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59278	17041-20000-44379	1129-1145 S SAN PEDRO ST	90015	14	124-5A211 227	5145025015	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.03457	-118.25289	Plan check for fire alarm system. New fire alarm system for commercial club. 1 FACP. 40 device.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59279	17041-10000-05478	19851 W NORDHOFF PL	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.23624	-118.56649	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR) 173290 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59280	15041-10000-16502	7335 N TOPANGA CANYON BLVD	91303	3	186B101   757	2023005025	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.20391	-118.60618	Change of use to dental office (healthcare facility).  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59281	19041-20000-52442	3773 S DURANGO AVE	90034	5	120B165   382	4313021085	MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	11/24/2020 12:00:00 AM		Issued	11/24/2020 12:00:00 AM	ADDRESS	34.02717	-118.39401	Plan check for PV roof mounted system, PV system size: 86.9KW DC, 66.36KW AC with 220 PV Modules and 1 inverter(66.6KW) Supply side connection.Permit Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59282	16041-20001-37425	4224 N LOUISE AVE	91316	5	165B133   351	2292002027	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	ADDRESS	34.14783	-118.50602	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 19.6 kWac and consists of (70) micro-inverters, (70) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59283	18041-10000-29191	18355 W ROSCOE BLVD	91325	12	192B125   495	2786022044	RA-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.22093	-118.53329	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59284	15041-10000-17659	1029-1031 S WESTWOOD BLVD	90024	5	132B149    34	4363018029	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.06193	-118.44564	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 3073.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59285	19041-30000-14833	4423 N SHERMAN OAKS CIR	91403	5	166-5A145  88	2283019003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.15116	-118.47048	Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (2) battery back-up units to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59286	14041-10000-30171	8450 N SAN FERNANDO ROAD	91352	6	192B173   284	2632027012	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.22351	-118.37448	Title 24 plan check only.  Total area = 8,140 sq. ft.Replace HID lighting with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59287	18041-10001-34045	17552 W TUSCAN DR	91344	12	222B129   241	2601044010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM			PC Approved	09/10/2018 12:00:00 AM	ADDRESS	34.30265	-118.51567	SUPPLEMENTAL FOR FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED (10.841AC) PV SYSTEM WITH SUNPOWER MONITORING SYSTEM, AND PANEL UPGRADE - SYSTEM CONSIST OF 36 AC MODULES(SPR-X21-35-D-AC).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59288	19041-20001-29703	7900 N BALBOA BLVD BLDG E	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	34.21347	-118.50092	"Revisions to approved plan.  Power and lighting revisions to accommodate minor architectural revisions. Approval for hand-drawn clouded areas signed by plan checker only. (((New 2-story commercial office addition connected to aircraft hangar building ""E"".  Service equipment permitted under 18041-20000-31255.  Plan check for power and energy.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59289	13041-20000-32801	10100 W SANTA MONICA BLVD SUITE 1250	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.06191	-118.41691	T24 FOR EXISTING HIGH RISE OFFICE SPACE. SCOPE OF WORK ON SUITE 1250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59290	17041-10000-42017	555 W 5TH ST STES 600 &-670	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	TENANT IMPROVMENT IN AN ENCLOSED OFFICE SPACEPLAN CHK IS FOR TITLE 24 AND 1 EM CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59291	18041-10000-01662	1836 N COURTNEY TER	90046	4	150B177   474	5551010034	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.10415	-118.35814	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.95KWdc / 12.88KWac.(46)MODULES-LG LG325N1C-A5(46)MICROINVERTERS-ENPHASE IQ6PLUS-72-2-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59292	16041-20000-29454	8115 N LANKERSHIM BLVD	91605	6	189B169    47	2310007012	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.218	-118.38798	"PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. Change of use from warehouse to manufacturing and interior ti for ""Granda hills discount pharmacy """	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59293	19041-20000-53241	110 E 9TH ST 7TH FLR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	Plan check for Title 24 Energy only in existing space. New lighting installed in addition to existing lighting. Total area: 23,191 sq ft. B#19016-10000-12902	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59294	16041-20000-41477	1447 N MARTEL AVE SLS#6	90046		147B181  1153	5550021013							Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Plans on Hold	12/02/2016 12:00:00 AM	ADDRESS	34.09728	-118.35102	New 4-story single family dwelling with subterranean attached garage.  Small lot subdivision.  Collective service for (6) new SFDs on same lot.  Plan check for power and energy.  Service equipment, house panel, and energy fees charged on unit #1.  Building permit filed under 16010-10000-02540 et al	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59295	12041-10000-04015	16650 W MARQUEZ AVE	90272	11	129B121   680	4415006025	C1-1XL	West Los Angeles	Brentwood - Pacific Palisades			2626.02	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	09/10/2012 12:00:00 AM	ADDRESS	34.04796	-118.5447	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR BEAUTY SALON. PERMIT FOR NEW 25 BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59296	13041-10000-17015	11024 W STRATHMORE DR	90024	5	135B149   462	4363016001	[Q]R4-1VL-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			06/26/2013 12:00:00 AM	09/24/2013 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.06471	-118.45062	PLAN CHECK POWER AND ENERGY FOR NEW 31 UNIT APARTMENT BUILDING WITH SUBTERRANEAN PARKING. New 31 unit 5-story Type IIIA apartment over 2 levels of Type IA parking garage. 2 units out of 31 units are very low income.Fire alarm variance filed 8/13/2013 - MT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59297	14041-10000-29871	2706 E MEDIA CENTER DR	90039	1	150B213  3657	5442032005	[Q]M2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Closed	04/13/2015 12:00:00 AM	PIN	34.10723782	-118.24232865	INSTALLATION OF NON-LEGALLY REQUIRED STANDBY GENERATOR IN COMPLIANCE WITH Article 702 OF THE NEC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59298	15041-20000-02619	12492 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59299	16041-20001-25589	1134 S CRENSHAW BLVD	90019	10	129B189   371	5081003016	C2-1-O	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM			PC Approved	08/19/2016 12:00:00 AM	ADDRESS	34.05178	-118.32436	Expedite per applicant request(((((Plan check for PV2 roof mounted system Commercial. System size: 6.4kW with 20 modules an 1 inverter(6.4kW)}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59300	19041-20000-12690	4047 N ELLENITA AVE	91356	3	162B117    47	2180004033	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.14379	-118.55994	Installation of 27 kWh energy storage system and associated distribution/critical backup panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59301	13041-10000-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59302	12041-20000-18347	1704 W MANCHESTER AVE	90047	8	097-5A193 332	6037014023	C2-1VL, [Q]R5-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00, 2384.00	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Expired	06/23/2015 12:00:00 AM	ADDRESS	33.95981	-118.30702	New roof mounted P.V. system with 38.25KWdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59303	18041-10000-42728	6420 W WILSHIRE BLVD #1120	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.06365	-118.36922	TI TO EXISTING COMMON AREA 1643SQ-FT TO SUITE 1120- 11TH FLOOR. 18016-10000-35273	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59304	12041-10000-02077	17256 W BRONTE PL	91344	12	222B133   278	2602011012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	07/31/2012 12:00:00 AM	ADDRESS	34.30505	-118.51008	NEW 9.16KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59305	17041-20000-36494	1200 W 7TH ST 9th flr	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.05136	-118.26616	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59306	19041-20000-44019	12442 W SARAH ST	91604	2	168B165   923	2364015011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.15384	-118.4045	PV1. INSTALL 5.11 KW DC PV SYSTEM WITH (14) MODULES AND (1) INVERTER (SOLIS-1P4K-4G-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59307	18041-10000-34687	9175 N ETON AVE	91311	12	198B105   139	2746010043	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.23779	-118.59431	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59308	14041-10001-34167	20969 W VENTURA BLVD	91367	3	171B109    73	2167001013	C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM			PC Approved	05/06/2015 12:00:00 AM	PIN	34.16701214	-118.59032578	REVISIONS TO LIGHTING SYSTEM NEW CKTS AND PANEL BOARDPLAN CHK IS FOR TITLE 24((((((((   TI to (E) restaurant commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59309	17041-10000-24540	304 S BROADWAY STE 310	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR OFFICE TI FOR TITLE 24 ENRGY ONLY.SCOPE INCLUDES NEW LIGHTS, RECEPTACLES AND NEW EQUIPMENT. TOTAL AFFECTED AREA 1405 SQ.FT.B# 17016-10000-15154	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59310	17041-10000-32127	15555 W SATICOY ST	91406	6	189B141   255	2222005001	RA-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.20861	-118.47223	TITLE 24 PLAN CHECK FOR REPLACEMENT OF EXISTING (62)HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 165200 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59311	13041-10000-07839	3614 S WESTERN AVE	90018	8	120B193  1364	5041015030	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.02223	-118.3087	PERMIT FOR INSTALLED EQUIPMENT. ORIGINAL PLAN CHECK FOR T24 COMPLIANCE UNDER APPLICATION # 13041-10000-07830RENOVATION OF INTERIOR LIGHTS. WORK TO BE DONE LESS THEN NEW PLAN CHECK REQUIREMENTS. PC FOR T24 ENERGY ONLY. TOTAL AREA 7447 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59312	12041-10000-11500	500 N PIER A ST	90744	15	027B205   619	7440009911	PF-1D	Harbor	Port of Los Angeles, Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Public Safety Only			05/18/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	33.76414	-118.26561	"Modification of existing fire alarm system for ""POLA TEST LAB""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59313	19041-10000-51271	11225 N CARRILO DR Lot 15	91345	7	210B145   528	2664027015		North Valley				1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	34.2743	-118.46861	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 10 MODULES (HANWHA Q.PEAK BLK-G5315), 10 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)SYSTEM SIZE: 2.835 KW DC;  3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59314	17041-20000-19448	1031 N BIENVENEDA AVE	90272	11	132B121   453	4420015001	RE15-1, RE15-1-H, RE40-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.04	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	06/18/2018 12:00:00 AM	ADDRESS	34.05371	-118.54108	Installation of electrical panel for pool equipment and outdoor lighting.  Plan check for power and energy per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59315	14041-20000-15931	13897 N ELDRIDGE AVE	91342	7	228B153   687	2503003019	RE11-1-K	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.32445	-118.43353	PV1.  Install 7.02 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59316	19041-10000-30774	7136 N WINNETKA AVE	91306	3	183B113   125	2135007022	RA-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.20039	-118.57079	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59317	17041-20000-24368	1111 S CARMELINA AVE	90049	11	126B141   218	4264019024	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	09/30/2017 12:00:00 AM	ADDRESS	34.04315	-118.47204	PV1.  Install 8.7 kW DC roof mounted grid tied PV system.  (30) panels with (1) SolarEdge 7.6kW inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59318	18041-10000-18188	20239 W WYNFREED LANE	91326	12	216B113   202	2701048001	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.29174	-118.57483	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PV 1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 17.67KWdc / 11.40 KWac.(57)MODULES- SILFAB SLA-M 310 MODULES(57) OPIMIZERS- SOLAREDGE P320(1)INVERTER-SOLAREDGE SE 3800H-US(1)INVERTER-SOLAREDGE SE 7600H-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59319	15041-10000-40657	2003 S OAK ST	90007	1	124-5A203 209	5124015903	PF-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Apartment			12/11/2015 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.03534	-118.27906	NEW 3-STORY 29 UNIT APARTMENT BUILDING WITH ONE LEVEL SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59320	12041-10001-30785	"12746 W JEFFERSON BLVD ""3"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	change to approved set, changes include adding circuits, removing and adding lighting, and relocate some electrical devices.(((Plan check power and energy for Building 3. Retail/Theater shell on top of common subterranean parking with Building 1, 2, and 4. Service supplying Building 3 and Building 4. Site located in methane zone. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59321	12041-20000-11273	8999 N BALBOA BLVD	91325	12	195B133     8	2690006017	(Q)C2-1VL	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.23353	-118.50275	Replace existing fire alarm system with all new.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59322	16041-20000-42531	11447 VANOWEN ST	91605	2	183B169   603	2320003015	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Issued	01/20/2017 12:00:00 AM	PIN	34.19427867	-118.38075191	Plan check for power only. Project site is an existing commercial building. Project scope is distribution equipment and electrical equipment (plant growth facility).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59323	16041-10004-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	02/19/2020 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.23567	-118.5584	PC FOR CHANGES TO APPROVED SET UNDER DELTA 18 AND 21  ONLY. DELTA 18 SCOPE INCLUDES : REVISION SPATIAL ARRANGMENT OF LIGHTS, LIGHTING CONTROLS AND RECEPTACLES INSIDE  DWELLING UNITS.DELTA 21 SCOPE INCLUDES:  NEW EV SUBPANELS NEW CIRCUITS, EQUIPMENT AND LOADS,  RELOCATION OF EV CHARGERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59324	17041-20000-41621	12700 W VAN NUYS BLVD bldg 11,12-,13	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			11/16/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	pv2install roof mounted pv system sized 32.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59325	16041-10000-26138	21400 W NORDHOFF ST	91311	3	198B105   199	2779018021	C2-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Expired	10/03/2018 12:00:00 AM	ADDRESS	34.23522	-118.59776	**Zero permit fee due per CA Senate Bill 1222.PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 52.08KWdc / 50.00KWac (3 phase system). (168)MODULES-CANADIAN SOLAR 310(4)INVERTERS-SOLAREDGE SE12.5KOPTIMIZERS-SOLAREDGE P700 IS USED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59326	19041-10000-03882	11600 W PICO BLVD	90064	11	123B153   652	4260033045	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			02/04/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.03227	-118.44393	CHANGE OF USE FROM OFFICE/RETAIL TO AMBULATORY SURGICAL CENTER- PLANS SHOW TWO SURGICAL ROOMS ; B-OCCUPANCYBLD# 18016-30000-31920	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59327	19041-10000-52823	4707 N VANTAGE AVE	91607	2	168B165   701	2356036023	R1-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.15596	-118.39782	PV1. PLAN CHECK TO ADD 4 MODULES AND 4 OPTIMIZERS TO AN EXISTING ROOFMOUNTED SOLAR SYSTEM . ALL OTHER EQUIPMENT ARE EXISTING TO REMAIN. EXISTING SOLAR SYSTEM APPROVED UNDER 18041-90000-39437	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59328	10041-20000-23157	15760 W VENTURA BLVD #1040	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	12/21/2010 12:00:00 AM	ADDRESS	34.1552	-118.47684	energy plan check suite # 1040	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59329	11041-10000-12757	101 WORLD WAY parking	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/11/2011 12:00:00 AM	ADDRESS	33.94489	-118.40086	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59330	18041-10000-36447	11555 W CANTARA ST STE I	91605	6	192B169   514	2311001012	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Issued	09/25/2018 12:00:00 AM	ADDRESS	34.21938	-118.38398	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59331	15041-10000-25954	2002 W SLAUSON AVE	90047	8	105B189    20	6001001900	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM			PC Info Complete	10/15/2015 12:00:00 AM	ADDRESS	33.98891	-118.31398	PV2 INSTALL ROOF MOUNTED SOLAR SYSTEM SIZE 60KW 267 PV MODULES  INTERCONNECTED WITH MAIN SERVICE PANEL.PERMIT FEE $0 IS DUE TO SENATE BILL 1222 ; ORIGINAL SUBMITTAL WAS FOR A 26KW SYSTEM REFERENCE APP# 15041-10000-25943FOR POWER AND ENERGY PLAN CHK APPROVAL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59332	18041-10000-16079	1055 W WILSHIRE BLVD #1200	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.05232	-118.2629	PC FOR OFFICE TI TITLE 24 ENERGY ONLY (UNIT 1200) IN A HIGH RISE BUILDING. SCOPE INCLUDES NEW PANEL, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 14955 SQ.FTB# 18016-10000-08578	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59333	19041-10000-25104	8825 N KESTER AVE	91402	6	195B149   277	2653006***	OS-1XL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.23088	-118.45762	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59334	18041-20001-48554	9733 N TOPANGA CANYON BLVD	91311	12	201B101   839	2727023003	[Q]CR-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM			PC Approved	09/09/2019 12:00:00 AM	ADDRESS	34.24693	-118.60718	09-09-2019 Changes to an approved set of plan, Changes include remove scope of work, remove proposed lights from previous set. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59335	17041-10000-06032	1320 E 7TH ST #100	90021	14	127-5A211 173	5145001006	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.03598	-118.24041	Plan check for power and energy 1st time tenant restaurant TI with Mezzanine. Total area: 3631 sq ft. B#:15016-10000-06686	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59336	13041-10000-07822	380 W WORLD WAY T38	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	01/06/2014 12:00:00 AM	PIN	33.94461393	-118.39808495	renovation of retail space. new restaurant. FULL PLAN CHECK FOR POWER AND ENERGY PER INSPECTOR REQUIST. BACK ROOM SUBMITTAL. TOTAL ENERGY 625 SQ FT. ASSIGN TO FRANCIS. LAX AIR PORT CONCESSION. TOM BRADLEY TERMINAL. T38	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59337	15041-30000-35478	8901 N CANOGA AVE	91304	3	195B105   360	2779047020	[Q]MR1-1VL, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.23186	-118.59777	Title 24 plan check only.  Total area = 7,629 sq. ft.    Lighting, receptacles, and two HVAC units to new office expansion.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59338	15041-10000-18980	3224 N GLENDALE BLVD	90039	13	153B209   216	5436025001	[Q]C4-1XL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.11798	-118.26045	TI TO AN EXISTING RESTAURANT.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2230.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59339	16041-20000-11655	13950 N OLIVE GROVE LANE	91342	7	231B153    55	2582005***	QRD5-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.32591	-118.43836	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (36) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59340	18041-10000-03105	5101 S EDSEL AVE	90066	11	105B161   409	4221011059	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Expired	09/11/2023 12:00:00 AM	ADDRESS	33.98559	-118.4163	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. , CONISIT OF 14 MODULES(#SC325) AND A CENTRAL INVERTER (DELTA SOLIVIA 3.8) . SYSTEM SIZE IS 3.8KWac AND 4.55KWdc.INSPECTOR TO VERIFY 100A BREAKER IS DUAL RATED 60/75 DEG C TERMINAL LUGS.SCOPE INCLUDES TWO NEW LOAD CENTER (200A each).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59341	16041-10000-16238	18213 S NORMANDIE AVE	90248	15	063B197   331	6108017012	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	33.86526	-118.2997	PV1 INSTALL NEW 5 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE .(24) MODULES: CANADIAN SOLAR CS6X-315P(1) INVETER: GROWATT-5000MTL-US(240V)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59342	17041-10002-36567	5522 W 79TH ST	90045	11	099B173   672	4127022015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	33.96465	-118.37611	CHANGES TO AN APPROVED SET OF PLANS FOR A PV SYSTEM. CHANGES INCLUDE REMOVING 3 MODULES AND REARRANGING MODULES ON THE ROOF-LAYOUT. NOTE: PERMIT IS PAID UNDER PCIS#17041-10000-36567	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59343	18041-10000-23792	906 E 80TH ST	90001	9	099B209   385	6029005026	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	33.9664	-118.25829	PLAN CHECK FOR ROOF MOUNTED PV(SYSTEM 1 OF 2) SYSTEM - TOTAL SIZE IS 5.0 KVA CONSISTING OF 1 CENTRAL INVERTER (SUNNY BOY-5.0US) WITH 17 MODULES NOTE: PROJECT TO BE ASSIGNED TO ONE PLAN CHECKER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59344	18041-10000-23447	1035 N SWARTHMORE AVE	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	NEW 61.05 KW PV SYSTEM WITH 185 PV MODULES ON THE ROOF.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59345	14041-10000-02049	9989 W REEVESBURY DR	90210	5	153B153   283	4383023012	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.11163	-118.43715	addition of 1 module to 13041-10000-18476. PV1 7KWdc. 240V. xmfrLESS/Ungnd. NONstd. 3story. Roofmount. [(1) inverters: {SOLAREDGE SE6000A-US}]. [(28)modules: {Trina {TSM-250PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59346	19041-10000-53448	1417 W 3RD ST	90017	13	133-5A207 275	5153028021	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	34.05866	-118.2621	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59347	18041-10000-38877	11101 S AVIATION BLVD	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	33.93392	-118.37959	Remove Indoor/outdoor HID fixtures and replace with new LED fixtures - T-24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59348	13041-10000-05292	6060 W CENTER DR 3RD FL	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/28/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	33.97602	-118.39073	REMODELING OFFICES-NEW CKTS;PANELBOARDS;PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTPERMIT IS TO BE OBTAINED AT ELECTRICAL COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59349	14041-10001-06473	9892 N ARLETA AVE	91331	6	201B153   169	2645009055	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.25013	-118.43432	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL7.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH  MAIN SERVICE PANEL.(29) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-6000-OUTD-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59350	18041-20001-23507	611 N FAIRFAX AVE	90036	5	141B177   859	5527017012	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.08204	-118.36164	11/15/2018changes to an approved set of plans.  changes to add square footage to energy calculations.  changes noted delta 5 only.  plan check for energy only. this is plan check only.   ((((Plan check for Title 24 Energy only T.I. existing space. Total area: 1290 sq ft.B#18016-10000-10381))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59351	15041-20000-39938	13317 W HARDING ST	91340	7	222B157   661	2513011025	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.30101	-118.42404	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. SCOPE INCLUDES AN ADDITION OF 4 MODULES WITH MICROINVERTERS TO EXISTING PV SYSTEM. TOTAL ADDITION TO PV SYSTEM IS 860Wac. TOTAL SYSTEM SIZE IS 3.6KWac.(4)MODULES-275W SOLARWORLD MONO BLK(4)MICROINVERTERS-ENPHASE M215-60-2LL-SX-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59352	13041-20000-35790	542 E ROSE AVE	90291	11	111B141   333	4240010008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	33.99853	-118.47286	New mixed use with 2 residential units and retail space.  Full Plan Check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59353	14041-20000-07575	1430 E WASHINGTON BLVD	90011	9	120A213   272	5129006028	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	PIN	34.02232585	-118.24732255	pc for power and energy 4- STORY BUILDING W/ 1ST FLOOR TYPE 1-B WAREHOUSE, 2ND FLOOR TYPE V-A OFFICE ANDper building submittal, plan check in accordance to 2008 NEC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59354	14041-10000-02874	1504 S FLOWER ST	90015	14	126A205   221	5134012024	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.03748	-118.26827	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 4550 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59355	18041-10000-47136	611 E FLOWER AVE	90291	11	111B145   985	4240011022	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	33.99867	-118.4709	PV1 ROOFTOP SOLAR SYSTEM ON (E) SFD, INSTALL 13.5 KWH ENERGY STORAGE SYSTEM AND 3.25 KWDC PV ARRAY, WITH 10 MODULES(SC SC325), AND 1 INVERTER(UNO-DM-3.3-TL-PLUS-US-SZ).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59356	17041-10000-14693	2645 S CRENSHAW BLVD	90016	10	123B185   910	5050001027	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Apartment			05/03/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.03125	-118.33541	Insallation of fire alarm system in new 5 story 50 unit mixed use apartment building.  Total system size = 276 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59357	12041-10000-20792	9636 N CLAIRE AVE	91324	12	201B121   528	2762007010	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.24602	-118.55024	Plan check 4.578 KW roof mounted photovoltaic system (Aurora Transformerless Inverter). Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59358	10041-10000-22038	16923 W VANOWEN ST	91406	12	183B133   917	2230010003	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	34.19408	-118.50178	Ti for a Yogart shop. Plan check is for T24. (Plan check may required base on field inspection)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59359	16041-10000-02661	8804 S MCKINLEY AVE	90002	9	096A209   164	6042019016	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	33.95708	-118.26063	PV1, rooftop solar system 3kW AC (8) Triex U290, (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59360	17041-10000-28428	200 S SAN PEDRO ST 2nd &4th-Floor	90012	14	129A213    85	5161022023	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.04904	-118.24164	PC FOR OFFICE TI ON THE 2ND AND 4TH FLOORS FOR TITLE 24 ENERGY ONLY.  TOTAL  AFFECTED AREA 18,000 SF (COPIED SQ.FT FROM BUILDING APPLICATION)B# 17016-10000-22715	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59361	11041-10000-23029	3560 S WATT WAY PED 130U	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	12/05/2011 12:00:00 AM	ADDRESS	34.02169	-118.28671	T-24 lighting plan check for a remodeled physical education office, room PED130U.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59362	17041-10000-20546	700 S FLOWER ST Ste G600	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Title 24 plan check.  Change of use from retail to restaurant in tenant space G600.  One new 480 volt 200 amp subpanel feeding 75 kVA transformer and two 208 volt subpanels.  New lighting and receptacles.  Lighting area = 1,973 sq. ft.       Building permit #17016-10000-14510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59363	18041-30000-46968	1127 S SPAULDING AVE	90019	10	132B177  1059	5086026017	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.05541	-118.36046	NEW FIRE ALARM PANEL FOR AN APARTMENT LOW RISE BUILDING. (1) FA PANEL AND (70) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59364	14041-20000-20989	12540 W VOSE ST	91605	2	183B161   427	2324031008	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.19835	-118.40673	New roof mounted PV system with Optimizers, total system size 7KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59365	19041-20000-07061	7007 W ROMAINE ST	90038	4	144B181   604	5532030011	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/27/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.08901	-118.34188	Plan check for first time tenant for Bakery/Restaurant in a mixed use building. Total area: 2,558 sq ft. B#18016-10000-37649	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59366	16041-20001-38704	13359 N MISSION TIERRA WAY	91344	12	225B133    97	2601013040	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM			PC Approved	11/16/2016 12:00:00 AM	ADDRESS	34.31264	-118.50167	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. 12kW (6+6) ungrounded system. (50) 320W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59367	16041-10000-08270	633 W 5TH ST 4TH FL	90071	15	015B197   195	7451029032	[Q]R3-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.05099	-118.25468	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT NEW INTERIOR FINISHES, SELECT KITCHEN AND BAR EQUIPMENT. SCOPE INCLUDES NEW LIGHTING IN THE KITCHEN AND BAR AREAS. TOTAL AFFECTED AREA IS 10,581 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59368	17041-10000-33211	8717 W VENICE BLVD	90034	10	123B169   835	4312004027	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.03259	-118.38305	Full plan check for power and energy to existing 2 story office building. Service upgrade to 600A 120/240 3ph, 4W. Total area for T24: 5,119 sq.ft ((B# 17016-30000-07962))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59369	18041-10001-03800	320 N MADISON AVE	90004	13	138B197   191	5501002032	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	06/11/2018 12:00:00 AM	ADDRESS	34.07708	-118.28902	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYTEM SIZE IS 9.10KWdc / 9.00KWac. (26)MODULES-Hyundai His-S350TI(26)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE9KUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59370	19041-10000-49308	5922 S FIREFLY PL	90094	11	102B161  1277	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	33.97575	-118.4142	Plan check for a PV1 7.5KW DC / 9.79KW CEC roof mounted system. Scope includes (1) inverter, (1) combiner panel, and (23) AC modules interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59371	15041-20000-28860	19780 S PACIFIC GATEWAY DR	90502	15	057B197    48	7351034069	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	33.85141	-118.29512	Plan check for Title 24 only for warehouse. Total indoor area: 67,000sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59372	17041-10000-17150	4201 W WILSHIRE BLVD 1st floor	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Info Complete	05/23/2017 12:00:00 AM	ADDRESS	34.06189	-118.31911	TI to 1st floor interior corridor of (E) commercial highrise building.  Plan check for energy only. total area = 2550 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59373	13041-10000-12075	6151 W PICO BLVD	90035	5	129B173    23	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM			Not Ready to Issue	06/21/2013 12:00:00 AM	ADDRESS	34.05337	-118.37542	THIS IS A ONE STORY RETAIL, TITLE 24 ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59374	12041-10000-17889	3620 S MCCLINTOCK AVE	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.0213	-118.28935	RENOVATION OF OFFICES/  MELOT LABORATORY ON THE 2ND FLOOR OF THE SEELY G MUDD BUILDING PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59375	18041-20000-30621	20045 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27564	-118.57092	Plan check for 1st time tenant Porter Ranch Shopping Center new lighting and electrical distribution for new retail space. Total area: 10,250 sq ft. B#18016-20000-26028	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59376	17041-20001-14857	10651 W LEDEEN DR	91342	7	213B177    20	2529017013	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM			PC Approved	06/02/2017 12:00:00 AM	ADDRESS	34.27976	-118.36257	pv1install roof mounted pv system sized 12.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59377	16041-20000-38656	5925 N CALVIN AVE	91356	3	177B117   743	2153031011	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.17817	-118.55587	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.120 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59378	14041-20000-05126	417 S BARRINGTON AVE	90049	11	132B145   106	4401010011	R3-1, RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			02/25/2014 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.06037	-118.46868	NEW 34 UNIT APARTMENT BUILDING. METHANE BUFFER ZONE, fire alarm variance was filed, pc extensions were filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59379	13041-20000-31294	609 E ROSE AVE	90291	11	111B141   207	4240003002	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	33.99941	-118.47189	OVERHEAD 600A SERVICE UPGRADE FOR COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59380	13041-20000-11730	9310 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.23949	-118.53589	T24 FOR EXISTING PARKING LOT. INSTALLING NEW LIGHTS AND REWIRING EXISTING LIGHTS. 12780 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59381	15041-20002-25051	16940 W KNOLLWOOD DR	91344	12	216B133   401	2610001002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM			PC Approved	09/22/2015 12:00:00 AM	ADDRESS	34.28761	-118.50039	09-22-2015 Change to approved set of plans. Changes includes main breaker from 175A to 200A.[[[[[[Plan check for a PV1 roof-mounted PV system. System size is 11.3 kWac and consists of (2) inverters, (36) modules, and (1) load center.]]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59382	17041-10000-25814			14	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM			Corrections Issued	08/22/2017 12:00:00 AM	PIN	34.04442206	-118.26324876	FULL PC FOR POWER AND ENERGY. INTERIOR TI TO (E) OFFICE ON 5TH FLOOR. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES AND UPS. B#17016-10000-20566.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59383	11041-10000-20324	5570 N CAHUENGA BLVD	91601	2	174B177   598	2417001043	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/26/2011 12:00:00 AM	ADDRESS	34.17184	-118.36137	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59384	13041-10000-12591	11354 W SATICOY ST UNIT 2	91352	2	186B173   281	2315015048	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.2083	-118.37876	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ON A TENANT IMPROVEMENT FOR A RETAIL LOCATION. SCOPE OF WORK INCLUDES 540 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59385	11041-20000-09009	8220 N WOODMAN AVE	91402	6	192B157   780	2213021019	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	34.22035	-118.43224	energy plan check riser room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59386	13041-20000-25412	1929 W ESTES ROAD	90041	14	163-5A223  19	5671005010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.14389	-118.21086	PV1 TRANFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.75KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59387	14041-10002-04667	4652 N WORTSER AVE	91423	4	168B161   660	2362003002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Expired	08/11/2016 12:00:00 AM	ADDRESS	34.15553	-118.4169	PV1 CHANGES TO APPROVED; ADDING 3 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59388	13041-20000-01798	730 N AMALFI DR PV-1	90272	11	126B133   130	4408015004	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.04191	-118.51143	"SOLAR SYSTEM SINGLE FAMILY.  Ungrounded System using ""Power Optimizers""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59389	15041-20001-18901	10100 W SANTA MONICA BLVD 1st  Floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM			PC Approved	10/30/2015 12:00:00 AM	ADDRESS	34.06191	-118.41691	10/30/2015 Changes to an approved set of plans. Changes have been made to the light fixture schedule: Fixture F2 has been switched for another, a new Fixture F2A has been added, and there have been changes to the area of work. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only. Pro ject site is 1st floor of an existing highrise commercial building. Project scope T.I. Total indoor area: 4.493 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59390	14041-20001-04229	6438 N ALDEA AVE	91406	6	180B133   450	2230022007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	34.1879	-118.50777	((((expedite fees)))pv1 single family dwelling. total system size 6kw ac using transformerless inverter nonstandard plan. using string combiner for dc system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59391	15041-10000-23911	835 W BLOOM WALK 1ST FLOOR	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Closed	02/19/2016 12:00:00 AM	ADDRESS	34.01948	-118.2876	TI ON EXISTING COMMERCIAL BUILDING ON A LAB, TITLE 24. PC FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN ROOMS 131, 132, AND 133. NO NEW LIGHTING IN ROOM 114. TOTAL AREA = 1722 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59392	19041-10001-01233	11687 W NATIONAL BLVD	90064	11	120B153   978	4258009010	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM			PC Approved	09/16/2019 12:00:00 AM	ADDRESS	34.023	-118.4384	DELTA 2 CHANGES TO APPROVED SET TO MATCH AS BUILT CONDITIONS PER INSPECTOR REQUEST. REMOVING DENTAL CHAIRS IN OPARATORY 4, 5 AND 6 AND MARIKING THEM AS UNFIRNISHED. NO OTHER CHANGES ARE APPLIED.  (((FULL PLAN CHECK FOR A T.I  FOR AN EXISTING MEDICAL OFFICE. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 1,895 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59393	16041-10000-09230	401 S OCEAN FRONT WALK	90291	11	109-5A141 128	4286029001	R3-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	33.99386	-118.47965	ALTERATIONS IN KITCHEN/DINING AREAS OF CADILLAC HOTELPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59394	13041-10000-13719	810 S BROADWAY	90014	14	127-5A209 152	5144016065	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.04333	-118.25487	New 800A service for Urban Outfitters.  Install new 800 integrated facility switchboard.  Plan check for power and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59395	16041-10002-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.23567	-118.5584	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF CIRCUITAND LOCATION OF ROLLER SHADE - CHANGES APPROVED UNDER DELTA 8, AND B8PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE  APARTMENT WITH 215UNITS.   AND RESTAURANT/ RETAIL CORE & SHELL.  FOUR FLOORS OF RESIDENTIAL OVER TWO FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL. THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMP, 4000 AMP, AND 1600 AMP.  TOTAL AREA = 408,828 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59396	16041-10000-44063	10250 W SANTA MONICA BLVD 1600	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Chase"" Ste. 1600.  Install new Xrfmr, and  panels, total area 4,580 sq.ftPower fed from MS-1801"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59397	18041-10000-42899	3616 S TROUSDALE PKWY #B30	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.01983	-118.28534	TITLE 24 ONLY FOR OFFICE, REMOVING EXISTING LIGHT FIXTURES AND REPLACING WITH NEW DIFFERENT LIGHT FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59398	15041-10000-11043	19821 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	33.85044	-118.28771	T24 ONLY, REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 5580 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59399	14041-10000-10174	7475 W BEVERLY BLVD	90036	5	138B181   412	5526039031	C2-1VL-O	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.07631	-118.35301	Plan check for energy only. Less than 400A, emergency lights installed. PROPOSED NONSTRUCT INT T.I. OF EXISTING DELI (TAKE-OUT)/MARKET & COFFEE SHOP AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59400	17041-10001-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	SUPP. PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER DELTA 2 (BULTIN A4)SCOPE INCLUDES CHANGES TO EQUIPMENT FOR: ELECTRICAL SIZE, ADDITION OF CIRCUITS AND REMOVAL OF CIRCUITS. Original permit descriptionPANEL SCHEDULES HAVE BEEN REVISED TO REFLECT ALL CHANGES. PC for power and energy for core and shell ancillary building in LA football club. PC for new distribution boards, new equipment, transformers and panelboards. Total area is 56258 sqft. Building #16041-10000-05104	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59401	16041-10001-11262	2311 N PASADENA AVE	90031	1	139-5A221 204	5205023003	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM			PC Approved	10/12/2017 12:00:00 AM	ADDRESS	34.07605	-118.21752	Supplemental PC for addition of outdoor light fixture.PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59402	13041-20001-23090	18076 W TULSA ST	91344	12	210B125   592	2715036019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	34.26964	-118.5268	"Roof mounted photovoltaic system.  System is Ungrounded, 11.4 kw.  Plan check/Permit is for PV System only, Not for Service Upgrade or to derate the main breaker. "" $0 permit fee is due to the 2012 Senate Bill No. 1222""(((CHANGES TO APPROVED SET OF PLANS. ADDED SLOT FOR METER SOCKET. NO OTHER CHANGES. REAPPROVAL FOR SINGLE LINE. NEW PAGES SWAPPED IN "" $0 permit fee is due to the 2012 Senate Bill No. 1222""))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59403	10041-10000-25160	13573 W VENTURA BLVD	91423	5	165B157   648	2360007030	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.1479	-118.42941	REMODELING OF SUSHI RESTAURANTPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59404	14041-10000-01724	1776 E CENTURY BLVD	90002	15	091-5A213 149	6048028046	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	33.94541	-118.24162	Installation of an addressable fire alarm system in (E) commercial building.  136 devices coordinated by Silent Knight IntelliKnight 5808 Single Loop Addressable FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59405	18041-10000-03982	13454 W RANGOON ST	91331	6	195B157  1028	2627005010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM			Corrections Issued	02/02/2018 12:00:00 AM	ADDRESS	34.22818	-118.42609	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCUDES 37 MOUDULES WITH OPTIMIZERS AND SINGLE INVERTER. SYSTEM SIZE 10.73 KWDC AND 10KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59406	17041-10001-45508	2810 E WHITTIER BLVD	90023	14	123A223   177	5189004019	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.0315	-118.20975	EXPEDITE PER APPLICANT REQUEST.PC FOR ROOF MOUNTED PV ON COMM. BUILDNG. SYSTEM SIZE 56.KWDC AND 53.3KWAC. SCOPE INCLUDES 162 MODULES WITH 81 OPTIMIZERS AND TWO CENTRAL INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59407	14041-20000-17360	333 S ALAMEDA ST	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.04448	-118.23824	Tittle 24 plan check on a redmodel of an exisitng retail store with 8200 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59408	15041-10001-38337	1430 W MIRAMAR ST	90026	13	133-5A207 232	5153028015	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	34.05965	-118.2619	Supplemental PC for power for downsized service conductor. All changes clouded under delta 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59409	19041-20000-40914	18793 W LOS ALIMOS ST	91326	12	207B121   302	2717024032	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.26522	-118.54292	PV1.  Install 7.59 kW DC / 7.6 kW AC roof mounted grid tied PV system with energy storage system.  (23) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59410	15041-20000-36727	7715 N WOODHALL AVE	91304	12	189B093   665	2027030014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.21108	-118.63715	"GROUND MOUNTED SOLAR SYSTEM (3'-6"" HIGH MAX, 10' X 55')8.265 kW system(29) modules: SW285(1) inverter: FRONIUS 7.6Building permit already approved."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59411	13041-10001-35711	1186-1188 E 43RD PL # 1188	90011	9	114A209   376	5115034014	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.00466	-118.25446	Expedited RSES plan check per applicant request.{{PV1, Install 2.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (10) modules Trina Solar TSM-250PA05.18.One of two systems on the same building from range 1186 to 1188 43rd pl.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59412	16041-20000-42417	7417 N LOUISE AVE	91406	6	186B133   692	2228015001	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/14/2016 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.20522	-118.51003	Plan check for installation of solar pv system, roof-mounted on detached garage of SFD. Interconnect with a 200A MSP. Derating main to 175A. 6kW ungrounded system. (25) 260W pv modules. There is an existing 3kW system on the SFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59413	19041-20001-47191	5623 W 77TH ST	90045	11	099B169   456	4104020016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	03/29/2023 12:00:00 AM	ADDRESS	33.96861	-118.37953	Supplemental permit to correct work description: PV1.  Install 9.92 kW DC / 7.6 kW AC roof mounted PV system with 9.8 kWh energy storage system.  (31) modules with 7.6 kW rated inverter, 5 kW battery, autotransformer, and subpanel.  $0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59414	19041-20000-41346	1533 S SELBY AVE 1-66	90024	5	132B153   910	4325028010	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	06/23/2021 12:00:00 AM	ADDRESS	34.05466	-118.43755	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR EXISTING 2-STORY APARTMENT BUILDING. SCOPE OF WORK CONSISTS OF 1 FA PANEL AND (46) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59415	13041-20000-30343	1520-1520 1/2 S WESTERN AVE	90732	15	012B193   434	7560013045	R2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	11/08/2013 12:00:00 AM	ADDRESS	33.72974	-118.31291	PC ONLY FOR 2 FAMILY DWELLING. PV SYSTEM. 10 KW AC USING 2 CENTRAL INVERTERS. NONSTANDARD PLAN. 4 STRINGS.(((((PERMIT ALREADY ISSUED UNDER APPLICATION # 12041-10000-20762)))))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59416	18041-20000-42224	16174 W WOODVALE ROAD	91436	5	165B141   463	2285011025	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.14529	-118.4803	Plan check for PV roof mounted system and Energy Storage System, PV System size: 15.43KW, 17.6kW AC and Energy Storage System size: 54kWh with 49 PV Modules, 2 inverters(10.0kW and 7.6kW) with 4 Tesla PowerWall 2.0 13.5kWh interconnected to 400A Service.$0 permit fee due to State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59417	12041-10000-17402	8661 N SEPULVEDA BLVD	91343	7	195B145   524	2654020001	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.06	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.22796	-118.46792	Plan check power and energy for 7-Eleven. Core and shell approved under #12041-20000-07139	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59418	13041-10003-04818	680 S BERENDO ST	90005	10	132B197   130	5094008010	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			05/26/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.06064	-118.294	CHANGES TO APPROVED SET OF PLANS. THIS APPLICATION IS FOR CHANGE IN ELEVATOR CAB LIGHTS CONNECTION. CHANGE ALSO TO AIC RATING OF PANEL DBE. ALL CHANGES NOTED DELTA 5 ON THE PLANS. NO NEW CIRCUITS OR LOADS. THIS IS PLAN CHECK ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59419	14041-10000-17115	21031 W VENTURA BLVD	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Issued	06/25/2014 12:00:00 AM	PIN	34.16717222	-118.59179488	Title 24 plan check only.  TI to existing commercial low rise space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59420	15041-10001-06521	6316 N TOPANGA CANYON BLVD BLDG B	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM			PC Approved	07/09/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	(((7/9/2015- CHANGES MADE TO APPROVED SET. ADDING NOTE 21 TO ALL THE TENANT SPACES. CALCULATIONS TO BE REVERIFIED. ALL PERMIT FEES FOR REVISIONS ARE ON BUILDING A APPLICATION 15041-10001-06518)))NEW FIRE ALARM SYSTEM IN BUILDING B ON WESTFIELD PLAZA. 147 DEVICES AND ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59421	18041-20000-38000	13681 W FILMORE ST	91331	7	207B157   465	2619010021	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.26501	-118.43111	PV1.  Install 10.70 kW AC-CEC roof mounted grid tied PV system. (39) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59422	19041-10000-24364	7817 N LANKERSHIM BLVD	91605	6	189B169   659	2310025031	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.21268	-118.388	PC for T24 only, scope of work is adding new lighintg for a sales canopy, total affected area is 720 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59423	18041-20000-40549	16810 W MAGNOLIA BLVD	91436	5	171B133   367	2259002008	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Issued	10/23/2018 12:00:00 AM	ADDRESS	34.16481	-118.49948	PV1.  Install 3.9 kW roof mounted grid tied PV system and 13.5 kWh energy storage system.  (12) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59424	11041-10000-17761	9247 N VAN NUYS BLVD 1-56	91402	7	198B149   342	2651009003	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Apartment			08/26/2011 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.23862	-118.45064	BRAND NEW 56 UNIT APARTMENT BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  FIRE ALARM WILL BE ON A SEPERATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59425	15041-10000-20983	300 S WETHERLY DR	90048	5	138B169   551	4335014001	(T)(Q)R4-2-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	08/07/2015 12:00:00 AM		Permit Closed	09/28/2017 12:00:00 AM	ADDRESS	34.07338	-118.38859	TEMP POWER FOR CONSTRUCTION SITE 1600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59426	14041-10001-21130	501 W EL SEGUNDO BLVD	90044	15	081B201   259	6132002020	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	PIN	33.91663801	-118.28317828	Change to approved set by replacing the detecting system ( control panel and sensors) with different brand, all quantity of devicies remain the same. All changes are under delta-1 only.(((PC for methene gas detection system for a commercial building. 1 panel,  18 fire alarm devices.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59427	13041-10001-07221	432 S CURSON AVE TOWER 50	90036		135B177   134	5509004005							Electrical	Electrical	Apartment			12/31/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.0673	-118.35362	Manufacture simens has changed switch gear from a 4000 Amp to a tapered  bus 4000 sections, 3000 sections and 2500 sections.(12/31/2013){{Service upgrade to 4000A for a 13-story apartment building (Tower 50).  Install new switchboards, feeders, house panels, and replace unit panels.  All the existing branch-circuit conductors to be remained and reconnect to the replacement unit panels.  No work done on branch circuit equipment and lighting.  Plan check for power only.}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59428	19041-20001-50098	8391 N SAMRA DR	91304	12	192B097   243	2005005021	RS-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/18/2019 12:00:00 AM	ADDRESS	34.22215	-118.62898	EXPEDITED PER APPLICANT REQUEST.PV1. INSTALL 9.70 KW DC PV SYSTEM WITH (166) TESLA TILE MODULES, (2) INVERTERS, AND (2) ENERGY STORAGE SYSTEMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59429	11041-10000-11861	16350 W VENTURA BLVD	91436	5	168B137   410	2284001055	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM			PC Approved	06/30/2011 12:00:00 AM	ADDRESS	34.15688	-118.48955	TI TO A RETAIL COMMERCIAL BUILDING.  PLAN CHECK IS OTC FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59430	12041-10000-00573	814-828 E TRACTION AVE # 3D	90013	14	127-5A215 107	5163013006	(T)(Q)CM-1, M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM			PC Approved	01/10/2012 12:00:00 AM	ADDRESS	34.04489	-118.23562	Plan check T24 Energy for office space TI #3D	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59431	18041-10000-29642	1930 S SHELL AVE	90291	11	108B145  1219	4241028900	PF	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.99114	-118.45913	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59432	18041-20000-16896	5855 W 76TH ST	90045	11	102B169   407	4104013017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	33.97224	-118.38479	Plan check for battery back up system connected to existing PV System.  Battery LG Chem 9.8kWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59433	17041-10000-24171	230 N GAFFEY ST	90731	15	018B197   803	7448031031	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	33.74479	-118.29212	PC FOR T24 ENERGY ONLY. LIGHTING UPGRADES TO LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59434	15041-10001-19097	23221 S LOCKNESS AVE	90710	15	045B193   558	7438002038	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	33.81479	-118.30497	Permit was pulled under Express Permit (15041-70000-19097). This is Plan check only per inspector's request.*Using standard plan<Install a roof mounted photovoltaic system to existing single family dwelling  (2.805     KW) Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59435	16041-10000-07058	3644 E OLYMPIC BLVD	90023	14	118-5A227 227	5191024011	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.01861	-118.19927	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (CVS PHARMACY). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES FOR PHARMACY. TOTAL AFFECTED AREA IS 964 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59436	15041-10001-06232	700 W 9TH ST	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			04/07/2016 12:00:00 AM			Reviewed by Supervisor	04/21/2016 12:00:00 AM	ADDRESS	34.04579	-118.2618	PC FOR POWER AND ENERGY. RECHECKING ORIGINAL PLAN  FOR POER AND ADDITION OF T24 TO THE ORIGINAL. TOTAL AREA 1570 SQ FT.PERMIT  FOR POWER IS PULLED UNDER THE ORIGINAL APP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59437	17041-10000-28373	13838 W MERCER ST	91331	7	204B153   100	2618020037	[Q]P-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.25944	-118.43464	REMOVE HID  FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY.Total affected 113550 sq.ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59438	18041-20001-37633	8480 W BEVERLY BLVD	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM			PC Approved	11/05/2018 12:00:00 AM	ADDRESS	34.07577	-118.37599	Title 24 Part 6 plan check only for express permit issued under 18041-90000-37633.(((Tenant Improvement)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59439	10041-20000-07590	19344 W NORDHOFF WAY	91324	12	195B117    14	2783028041	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Commercial			04/26/2010 12:00:00 AM	05/12/2010 12:00:00 AM		Permit Finaled	05/24/2010 12:00:00 AM	PIN	34.23406986	-118.55605138	Installing light fixture for store. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59440	12041-20000-03330	6756 N SEPULVEDA BLVD	91405	6	180B145    39	2235004009	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	PIN	34.19340436	-118.46533373	Remodel existing space into a new coin operated laundry.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59441	15041-10001-06079	630 W HARRY BRIDGES BLVD	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM			PC Approved	04/03/2015 12:00:00 AM	ADDRESS	33.77068	-118.26868	EXPEDITE PER REQUESTROOF-MOUNTED ( ADMINISTRATION BLDG) INSTALLATION OF 7.2KW DC PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59442	19041-20000-21798	241 E LINNIE CL	90291	11	106-5A145 468	4227005018	RW1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	33.9846	-118.46681	Plan check for PV roof mounted system bettery energy storage system, PV system size: 6.4KW with 20 PV Modules  and 1 inverter(Huawei SUN2000 7.6KW) and battery 9.8KWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59443	12041-10000-14772	10533 W WASHINGTON BLVD	90232	11	117B165   259	4208008031	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.02	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.01772	-118.40444	Plan check for fire alarm system. 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59444	19041-10000-22796	3754 S DUNN DR	90034	5	120B165   970	4313006037	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	06/29/2021 12:00:00 AM	ADDRESS	34.02388	-118.40013	PV2. NEW COMMRCIAL ROOFTOP SOLAR SYSTEM CONSIST OF 32 MODULES (REC350TP2S), OPTIMIZERS (SE P370) AND A CENTRAL INVERTER (SE11400H-US). SYSTEM IS CONNECTED TO THE SUPPLY SIDE OF A 200A SEVICE. SYSTEM SIZE 11.2KWdc AND 11.4KWac	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59445	12041-10000-13903	666 W 28TH ST	90007	8	121-5A203 124	5123013410	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2077.10	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.02682	-118.2793	Install a new fire alarm at a Fraternity House.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59446	19041-10000-34090	7400 N VAN NUYS BLVD #100	91405	2	186B149   448	2215026048	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.20519	-118.44847	Replace fluorescent troffers with new LED retrofit kits (Indoor only)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59447	14041-10000-35415	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.01768	-118.42494	Relocate fire alarm control panel and 3 peripheral devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59448	16041-10001-38694	3023 E FUTURE PL	90065	1	148-5A217 268	5455012023	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.10112	-118.23114	CHANGES TO APPROVED SET OF PLAN FOR - INCREASE MODULE COUNT TO 26 MODULES WITH P-400 POWER OPTIMIZERS AND INCREASE INVERTER SIZE TO 7.6 KVA USING SOLAREDGE 76000H-USORIGINAL PERMIT PV1 roof mounted solar system installation. Installing a 6.0 kWac inverter along with 21 solar panels -	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59449	16041-30000-31230	10102 W ANGELO VIEW DR	90210	5	144B153   250	4357014021	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	12/07/2020 12:00:00 AM	ADDRESS	34.09356	-118.43392	Plan check for new SFD two story with basement. Service size: 600A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59450	12041-10000-01611	249 S BRISTOL AVE	90049	11	129B137    70	4406021016	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2012 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	10/17/2012 12:00:00 AM	ADDRESS	34.05329	-118.48773	Existing 600A underground service. Plan check for replacing existing 600A main switchboard with new 600A switchboard.  Replace two subpanels and install new steam unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59451	14041-10002-09802	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04797	-118.25815	OFFICE /ROOFTOP REVISIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59452	19041-20000-51549	4363-4365 N TUJUNGA AVE	91604	2	165B173   458	2365015024	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Apartment			12/13/2019 12:00:00 AM			PC Approved	12/13/2019 12:00:00 AM	ADDRESS	34.1493	-118.37918	Plan check for Energy only for new indoor and outdoor lighting. Total area: 6012 sq ft. B#18014-10000-06756	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59453	11041-10000-16277	8333 N VAN NUYS BLVD	91402	6	192B149   303	2638038002	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM			Corrections Issued	10/07/2011 12:00:00 AM	ADDRESS	34.22236	-118.44896	T.I.  Existing Walmart.  Remodel of the lights in the restrooms and an outdoor tire/battery area.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59454	17041-10000-08995	425 S PACIFIC AVE	90731	15	015B197    95	7451027021	[Q]C2-1XL-CDO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.74001	-118.28807	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES FOR OUTDOOR USE. TOTAL AREA 13800 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59455	18041-10001-48422	101 S THE GROVE DR J1A/J1B	90036	4	138B177  1131	5512003045	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	34.07256	-118.35874	change to an approved set. original  was T-24 ENERGY PC PER APPLICANT REQUEST. SCOPE OF WORK IS ADDING 1 NEW LIGHT FOR MINIMAL LIGHTING FOR INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59456	16041-20001-38179	5950 N LAUREL CANYON BLVD	91607	2	177B165   769	2340005037	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			Corrections Issued	01/19/2017 12:00:00 AM	ADDRESS	34.17861	-118.39631	Expedited plan check fee per applicant request.  (((PV2.  Install 48 kW DC roof mounted grid-tied PV system with line side tap.  (160) modules with Enphase C250 microinverters.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59457	17041-10000-01683	9700 S SEPULVEDA BLVD	90045	11	093B165   162	4124026900	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			Reviewed by Supervisor	02/23/2017 12:00:00 AM	ADDRESS	33.94782	-118.39596	Plan check for powwer only in existing building parking lot. Install Electrical Vehicle Charging staion in parking lot. Total load exceed 400A	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
59458	18041-20003-40070	4009 W MELROSE AVE	90029	13	141B197   435	5539020013	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM			PC Approved	10/17/2019 12:00:00 AM	ADDRESS	34.08371	-118.28728	10/17/19CHANGES TO APPROVED SET CHANGES TO BREAKER SIZE.<<<PV2.  Install roof mounted PV system sized 69.63 kW DC / 59.19 kW AC interconnected with MSP.  $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59459	18041-10001-03250	21419-21421 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM			PC Approved	06/28/2018 12:00:00 AM	ADDRESS	34.2574	-118.5979	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES CHANGES TO LIGHT FIXTURES. THIS IS PLAN CHECK ONLY !!PC for T24 only for new lights beauty salon TI. Installing two new panels, receptacles, lights and equipment. Total area is 2172sqft. B# 18016-10000-02822.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59460	14041-20000-10185	420 S OXFORD AVE	90020	10	135B193   503	5503013007	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.06655	-118.30767	PV1.  Install 8.64 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59461	19041-10000-26659	14742 W ORACLE PL	90272	11	132B129    48	4422032011	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.05552	-118.52033	PV1 new rooftop mounted system, system size is 7.6 KWac. Scope of work is 24 modules (SLA-M 300) with optimizers (SEP320) leading to a central inverter (SE7600H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59462	13041-10001-24142	5771 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	33.94955	-118.38342	EXPEDITED PER APPLICANTS REQUESTPV3. NEUTROGENA MANUFCATORING PLANT. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 99.470 KW DC.SELECTRICA PV185 INVERTER. 406  MODULES.  2 OF 2 BUILDING ( DIFFERENT ADDRESSES)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59463	19041-20001-15377	18335 W RANCHO ST	91356	3	168B125   536	2184058002	A1-1XL	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.1543	-118.53224	Expedited plan check fee.PV1.  Install 16.5 kW DC roof mounted grid tied PV system interconnecting with 400A 240/120V 1ph-3w service.  (50) modules with (2) 7.6 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59464	10041-10000-23454	10250 W SANTA MONICA BLVD # 1030	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	02/18/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	"TI  TO EXISTING RETAIL LEASE SPACE FOR  ""SPERRY  TOP-SIDER"" SHOE STORE; 1499 SQ FTPLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59465	17041-20000-39235	17455 W FLANDERS ST	91344	12	213B129   188	2607009010	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.28065	-118.5138	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.075 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59466	14041-10000-21666	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	PIN	33.93847109	-118.41935625	INSTALLATION OF FEEDER   FROM DISTRIBUTION MSB-AAR (12041-10000-27220)  AND   JET FUEL  EMERGENCY SHUT OFF SYSTEM AT LAX	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59467	15041-20002-30865	687 S HOBART BLVD	90005	10	132B193   184	5093006033	(T)(Q)C2-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.0605	-118.30557	Revisions to approved set.  Reduction in effective combined conductor circular mil area on main feeders to comply with voltage drop requirements in 2016 Title 24 Part 6 Building Energy Efficiency Standards.  Request for modification to use the current code's voltage drop requirements granted by Michael Packard 01-03-2017.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59468	16041-10002-23791	1023 S ABBOT KINNEY BLVD	90291	11	109-5A143 439	4239021027	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	33.99219	-118.47181	REVISION TO THE APPROVED SET OF PLAN.  PROVIDING WITH UPDATED NOTE AND RESTAMPING THE PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59469	14041-10000-07318	13235 N GOLDEN STATE RD	91342	7	225B141  1518	2604002911	(Q)M1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	PIN	34.30933884	-118.48321136	PLANCHECK FOR T24 ENERGY FOR WAREHOUSE. NO CHANGE IN OCCUPANCY. TENANT IMPROVEMENT. NEWLY CONNECTED LOAD <400 AMPS. 14024 SQFT, EMERGENCY LIGHTING. CONTRACTOR DESIGN BUILD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59470	12041-10002-07426	1801 E 50TH ST 1st floor	90058	9	111A213   156	5106027004	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	33.99812	-118.24177	DELTA 3 REVISION TO APPROVED PLANS. PLAN CHECK FOR LIGHTING/EMERGENCY LIGHTING LAYOUT AND T24 ENERGY REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59471	19041-10000-28650	440 W O'FARRELL ST	90731	15	018B201   318	7449010019	R2-1XL-CPIO	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	33.74612	-118.28657	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 11 MODULES (Q-CELL 285) , 11 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3000H-US).  SYSTEM SIZE IS 3.14KWdc and 3KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59472	18041-10000-06626	11193 N DE HAVEN AVE	91331	7	210B161   249	2533014008	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2018 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.27366	-118.41336	Install New Rooftop solar panel on SFD, 7.6 kW AC / 8.99 kW DC system. (31) modules with P320 and (1) central inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59473	17041-20001-35215	8968 N WHITE OAK AVE	91325	12	195B129    71	2768027001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2017 12:00:00 AM			PC Approved	10/07/2017 12:00:00 AM	ADDRESS	34.23445	-118.51982	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.3kW ungrounded system. (12) 275W pv modules.Each module has a 320W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59474	15041-10003-10802	555 W REDONDO BEACH BLVD	90248	15	072B201    97	6120028006	C1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Expired	12/18/2017 12:00:00 AM	ADDRESS	33.89286	-118.28458	CHANGES TO APPROVED SET OF PLANS. ADDITION OF A POWER SUPPLY AND A FEW UNITS. RECIRCUIT TO NEW POWER SUPPLY. PC FOR CHANGES CLOUDED DELTA 3 REVISIONS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59475	17041-10000-10433	1530 N WILMINGTON BLVD	90744	15	036B201   454	7414028039	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.79362	-118.27493	Remove HID fixtures and rplace with new LED fixtures -T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59476	17041-10000-16651	2040 W JEFFERSON BLVD	90018	8	120B189   756	5042032023	C2-1VL-O-HPOZ, [Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.02542	-118.31636	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 38100 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59477	11041-10000-11649	3000 S WESTERN AVE	90018	8	120B193   427	5053008001	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM			PC Approved	06/08/2011 12:00:00 AM	ADDRESS	34.02707	-118.30874	NEW ADDITION TO A CHURCH.  T-24, OTC PLAN CHECK ONLY.  CUSTOMER ALREADY HAS PERMIT UNDER DIFFERENT PCIS NUMBER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59478	14041-10000-31542	12323 W HATTERAS ST	91607	2	174B165   227	2340013017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Expired	05/11/2017 12:00:00 AM	ADDRESS	34.17543	-118.40156	PV1.  SFD ROOF-MOUNTED PHOTOVOLTAIC 6KW SYSTEM	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59479	18041-10000-45239	639 S BROADWAY 9TH FLOOR	90014	14	129A211   230	5144003040	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Issued	11/28/2018 12:00:00 AM	ADDRESS	34.04587	-118.25309	PLAN CHECK FOR TITLE 24 ONLY FOR OFFICE TI ON CORRIDORS OF 9TH FLOOR - TOTAL AFFECTED AREA = 2045 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59480	15041-20000-20060	9154 N LANGDON AVE	91343	7	198B145   456	2656026***	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Expired	07/27/2017 12:00:00 AM	PIN	34.2371941	-118.46920441	Plan check for PV roof mounted system. System size: 7.6kW with 20 modules and 2 inverters(3.6kW) Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59481	18041-20000-45302	8591 N BIG ROCK TR	91304	12	195A089    16	2017021016	RE40-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	03/13/2019 12:00:00 AM		Issued	03/13/2019 12:00:00 AM	ADDRESS	34.22697	-118.65074	Plan check for PV Gound mounted system, PV system size: 12.9kW with 43 PV and 1 inverter(11.4kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59482	16041-20000-36138	21215 W BURBANK BLVD 5th Floor	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.17353	-118.59268	Plan check for Title 24 only. Project site is the 5th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 10,812 sq. ft.Note: Building application has been generated under 16016-20000-21587	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59483	15041-10000-07391	8431 W MELROSE PL	90069	5	141B173   416	5528001030	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.08376	-118.37442	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1387	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59484	18041-10001-00871	303 E 52ND ST	90011	9	108B205    70	5109024019	RD1.5-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM			Corrections Issued	02/05/2018 12:00:00 AM	ADDRESS	33.99537	-118.26985	PC for T24 only for commercial building. Installing new panel, reconnecting cirucits, new lights and receptacles. Total area is 554 sqft. master permit under 18041-10000-00871.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59485	16041-30000-41900	15157 W ROSCOE BLVD	91402	6	192B145   371	2654024013	(Q)RAS4-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.22161	-118.46296	Plan check for Fire alarm for new Fire alarm system in appartment builidng 39 units. Total Fire alarm devices: 99 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59486	18041-10000-41283	125 W 4TH ST	90013	14	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.0488	-118.24807	PLAN CHECK FOR TITLE 24 ONLY FOR EGRESS (MINIMUM LIGHTING) ONLY - FULL PLAN CHECK WILL BE REQUIRED WHEN TENANT MOVES IN - TOTAL AFFECTED AREA = 4600SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59487	15041-30001-37296	17550 W BURBANK BLVD	91316	5	174B129   852	2254037017	R3-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.17209	-118.51591	Expedite fees only.      Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 43 kWac.  System consists of 3 11 kWac inverters and 1 10 kWac inverter with 50 modules each.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59488	12041-10000-29337	13215 N INGRES AVE	91344	12	225B133   210	2602001010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.31013	-118.50405	recalc fees for new main service panel?PV1:  New 11 KW roof mounted PV system with a service upgrade for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59489	17041-10000-31479	2049 CENTURY PARK EAST # 650	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	PIN	34.05864553	-118.41292403	TITLE 24 PLAN CHECK FOR - INTERIOR TI @ SUITE 650 INCLUDING NON BEARING PARTITIONS, CEILING, MILLWORK, AND FINISHES - TOTAL AFFECTED AREA = 2230 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59490	15041-10000-26598	16429 W VICTORY BLVD	91406	6	180B137   740	2231005027	[Q]R3-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Apartment			08/14/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.18682	-118.49132	PC FOR ENERGY ONLY, T-24, TO A NEW 400AMP SERVICE APARTMENT BUILDING. SCOPE INCLUDES GARAGE AND OUTDOOR LIGHTING. TOTAL SQ. FT. 8941	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59491	18041-10000-27090	1640 S SEPULVEDA BLVD 400	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.04838	-118.44468	PC FOR POWER AND ENERGY FOR TI ON 4TH FLOOR TOTAL CONNECTED LOAD >=400 ASCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS LIGHTS. TOTAL AFFECTED AREA  11,430 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59492	15041-10000-25298	12540 W BEATRICE ST	90066	11	105B161   993	4211005013	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	33.98119	-118.41413	Energy plan check for sound studio T.I; scope includes new light, equipment and receptacles. Total area is 2593-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59493	15041-20000-18169	7450 N WISCASSET DR	91307	12	186B085   157	2017036018	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	PIN	34.20786502	-118.65907977	PLANCHECK FOR A NEW 13.33'x44' GROUND MOUNTED MICRO INVERTER SOLAR PANEL SYSTEM. 8.8 DC KW SYSTEM SIZE. BUILDING PERMIT: 15041-20000-01489	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59494	13041-20000-28462	11336 N CORBIN AVE	91326	12	213B117   422	2701004025	(T)RE11-1-H, [T]RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.27795	-118.56396	T24 FOR EXISTING YMCA. TOTAL NEW LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59495	17041-10000-43627	1108 W SANTA CRUZ ST	90731	15	018B193   599	7452005036	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	33.74476	-118.30084	PC for 5kW rooftop PV for SFD. Installing 25 new modules with optimizer and one central 5kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59496	16041-20000-40959	15000 N ANAYA DR	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.23827	-118.45904	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP.4.02kW ungrounded system. (12) 335W ac modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59497	13041-20000-31322	17021 W ROSCOE BLVD	91325	12	192B133   247	2690023192	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM			PC Approved	11/08/2013 12:00:00 AM	ADDRESS	34.22136	-118.50339	FLOURESCENT SIGN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59498	10041-20000-11073	9911 W PICO BLVD # 1010	90035	5	129B165    65	4330005043	C4-1VL-O	West Los Angeles	West Los Angeles			2690.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	06/10/2010 12:00:00 AM		Permit Finaled	06/30/2010 12:00:00 AM	ADDRESS	34.05339	-118.40441	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59499	17041-20002-14047	1044 S TIVERTON AVE	90024	5	132B153   151	4360002006	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.06077	-118.443	12-12-2018 Changes to an approved set of plan, Changes include increase feeder size and change from copper aluminum, addition of new transformer 45KAV. All Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59500	17041-20001-08746	14400 W ARMINTA ST	91402	6	189B149   664	2212001015	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Approved	04/18/2017 12:00:00 AM	ADDRESS	34.21259	-118.44646	04/17/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 313 sq. ft.*****Previous Work Description*****New receptacles and (1) relocated light for a new office space in an (E) open warehouse area.  Building permit filed under 17016-20000-05942.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59501	11041-10000-24415	12302 W EXPOSITION BLVD	90064	11	123B149   794	4259027001	M1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM			PC Approved	11/15/2011 12:00:00 AM	ADDRESS	34.03091	-118.45489	Delta 5 revisions only, revise and/or add luminaire types and add duplex receptacle outlets/	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59502	16041-20000-42753	9182 N KELVIN AVE	91311	12	198B109   125	2748036008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Issued	12/15/2016 12:00:00 AM	ADDRESS	34.23802	-118.58526	Plan check for installation of a solar pv system roof-mounted on a commercial building. Interconnect with a 400A MSP. 30kW (10*3) ungrounded system. (120) 275W pv modules.$0 permit fee per State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59503	16041-10003-28989	2005 W PICO BLVD	90006	1	129A201   230	5136023031	(Q)CM-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Approved	05/09/2017 12:00:00 AM	ADDRESS	34.04702	-118.28177	CHANGES TO APPROVED SET NOTED DELTA 1. CHANGE TO WIRE SIZE FROM INVERTER TO MAIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59504	18041-30003-20864	6222 W WILSHIRE BLVD 400	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.06309	-118.36418	03/12/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 7. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.01/15/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.11/08/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.*****Previous Work Description*****PLAN CHECK FOR ENERGY (T24) ONLY, TENANT IMRPOVEMENT TO (E) OFFICE BUILDING STE.400. TOATL AREA: 12,165 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59505	18041-10001-14025	20700 W SESNON BLVD GUARD-SHACK	91326	12	219B109   358	2761001***		North Valley			YES	1082.02	Electrical	Electrical	Apartment			05/30/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	02/23/2021 12:00:00 AM	ADDRESS	34.29545	-118.58467	TI in the GUARD SHACK. T-24 Energy Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59506	15041-20000-32089	8508 MORNINGSTAR LN	91305	3	192B105   728	2779010206	(T)(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	PIN	34.22495168	-118.59129718	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.  Central inverter system..	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59507	19041-20000-22212	22135 W ROSCOE BLVD LOT #30	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 30.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59508	19041-20000-40755	11211 N SEPULVEDA BLVD lot #45	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Closed	09/29/2021 12:00:00 AM	ADDRESS	34.27428	-118.46813	NEW SALES OFFICE FIRST TIME TENANT WITH 200 AMP 120/240 v SINGLE PHASE SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59509	17041-10000-14116	943 W 57TH ST	90037	9	108B197  1126	5001012017	[Q]R4-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Public Safety Only			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	33.99061	-118.29071	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 5950 SQ. FT. TOTAL OF 6 FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59510	14041-20000-29400	6701 S CENTER DR WEST SUITE 720	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			PC Approved	10/23/2014 12:00:00 AM	ADDRESS	33.97907	-118.39369	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING LIGHTING TO EXISTING POWER EQUIPMENT.  WORK TO BE DONE IN SUITE 720.  2100 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59511	11041-10001-19251	6701 N ETON AVE	91303	3	180B105    27	2148030035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.19217	-118.59564	REVISIONS TO PERMITTED SET OF PLANSNEW CIRCUIT FOR GATE MOTOR; CHANGES TO LIGHTING CIRCUIT ON EACH FLOORNEW 6-LEVEL (W/ ATOP ROOF PKG) OPEN PKG STRUCTURE ATTACHED TO 298-UNIT APT COMPLEX. See permit #11010-10000-00563 for separate apartment building permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59512	16041-20000-24899	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	33.93576	-118.3779	Plan check for power and energy Change of use from retail to a restaurant service upgrade 2000 A Service and new panels with some exiting load. Total area: 19,843 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59513	14041-10000-10525	12128 W VENTURA BLVD	91604	2	162B165   169	2369014005	C2-1VL, R4-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM			Corrections Issued	04/22/2014 12:00:00 AM	ADDRESS	34.14334	-118.39618	Title 24 for existing retail space expanding into another existing retail space.Total new connected load does not exceed 400A and not first time tennant for applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59514	19041-10000-41465	13160 W MINDANAO WAY 100A& 100B	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.98501	-118.43726	Energy plan check for an office T.I located on the 1st floor of a 3-story buidling. Scope includes new lighting and equipment with a total lighting area of 17,291 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59515	12041-20000-18810	7274 W MELROSE AVE	90036	5	141B181   621	5525013005	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	PIN	34.0832633	-118.34830747	T-24 and emergency lighting plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59516	12041-20000-27929	1418 N BROAD AVE	90744	15	036B205   965	7422009804	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	33.79195	-118.26154	New 300kw Fuel Cell System for an existing commercial low-rise building.  Site is in a Methane zone.  The designer has indicated that they will install the system to comply with Methane Level V.  The area is considered a Class 1 Division 1 area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59517	15041-20001-43046	964 S BERENDO ST PHASE 2	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.05378	-118.29358	Changes made to approved set - delta J revisons only.  Revision of lobby and theatrical lighting.  Reduced emergency inverter rating.  (4) fans, (1) BP, and additional audio equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59518	19041-20000-12348	6522 N LAUREL CANYON BLVD	91606	2	180B165   533	2322008051	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Issued	04/04/2019 12:00:00 AM	ADDRESS	34.18912	-118.39631	TI to (E) commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59519	16041-10000-39665	15419 W LEMAC ST	91406	6	189B145   607	2222008007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	34.21127	-118.4691	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.84KWdc / 6.0KWac. USING LADBS STANDARD PLAN.(28)MODULES-HANWHA Q-CELL. Q PLUS-G4 280(28)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE6000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59520	15041-20001-21589	11709 N PINE VALLEY PL	91326	12	213B117    27	2822020030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM			PC Approved	07/12/2015 12:00:00 AM	ADDRESS	34.28441	-118.55863	Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59521	15041-20000-13897	2300 W VALLEY ST	90057	13	135A205    71	5154012036	R3-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Apartment			05/07/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Closed	03/07/2016 12:00:00 AM	ADDRESS	34.06553	-118.27365	Plan check for Fire alarm system for a 3-story apartment building. Total devices: 67 + 1 FACP.Fire Deparment approval stamp on sheet A-4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59522	17041-20001-39113	5164 N KNOLLWOOD WAY	91364	3	171B097  1780	2075039007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	ADDRESS	34.16435	-118.61939	PV1.  Install 4.9 kW roof mounted grid tied PV system with battery backup. (15) modules with 7.6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59523	15041-20001-02622	12492 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	02/01/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	expedite per customer request.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59524	11041-20000-20353	11726 W SAN VICENTE BLVD	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.05328	-118.46625	T.I.  Remodel of the light fixtures within an existing office space Suite 225.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59525	16041-10000-42229	212-214 N LARCHMONT BLVD	90004	4	138B189   607	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.07517	-118.32344	PC for energy only to a retail commercial building. Installing new lighting and power. Total sqft = 2137.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59526	13041-10000-13596	1811 S OCEAN FRONT WALK STE194	90291	11	106-5A143 117	4226011034	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/24/2013 12:00:00 AM	ADDRESS	33.98561	-118.47247	permit to be pullled at EPC counter only. PC FOR ENERGY ONLY. TI TO EXISTING BLDG. RETAIL>RETAIL. less than 400A and no emergency lighting per applicant. suite 194 for themolife juice bar	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59527	16041-10000-42007	19812 W CANTLAY ST	91306	3	183B113    28	2115008009	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.20196	-118.56515	PC FOR T24 ENERGY ONLY. REPLACEMENT OF LUMINAIRES TO MORE ENERGY EFFICIENT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59528	15041-10000-07852	13333 W RIVERSIDE DR	91423	4	168B157   293	2359019008	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.15778	-118.4239	IN A RITE AID STORE, INSTALLATION OF 7 EACH 4FT 32WT8 LUMINAIRES IN NEW OFFICE SPACESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59529	19041-20001-21366	9763 N ABREGO CT LOT 11	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM			PC Approved	06/27/2019 12:00:00 AM	ADDRESS	34.24774	-118.45068	PLAN CHECK ONLY, SUPPLEMENTAL CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. MODEL TYPE CHANGE FROM SUNPOWER 335 TO SUNPOWER 350. SYSTEM RATING CHANGED TO 3.155KW DC/2.84KW AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59530	18041-20000-26950	888 S FIGUEROA ST ste 750	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.0465	-118.26225	ti to an existing dental office.  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59531	16041-20000-07521	4665 W MELROSE AVE	90029	13	141B193   563	5535036025	C2-1D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			03/02/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.08368	-118.30206	PLANCHECK FOR POWER. SERVICE UPGRADE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59532	14041-10000-08861	888 W 6TH ST STE 800	90017	14	130-5A209 182	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Expired	05/02/2016 12:00:00 AM	ADDRESS	34.05062	-118.25846	PC FOR ENERGY ONLY. HIRISE (E) OFFICE [AREA OF WORK = 5000SF]. Less than 400 A connected. Hirise and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59533	18041-20001-25819	22510 W BALLINGER ST	91311	12	198B101    26	2727001022	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Expired	04/27/2024 12:00:00 AM	ADDRESS	34.24321	-118.61768	07-20-2018 Changes to an approved set of plans, changes include PV module manufacture from LG330N1C-A5 to PANASONIC HIT 330WFees $0.00 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59534	14041-20001-15999	10921 W ART ST	91040	7	201B173   206	2542011008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.24865	-118.36837	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. STANDARD PLAN MAY NOT BE USED. PV SYSTEM INTERCONNECT TO A 400A SERVICE VIA 60A SOLAR BREAKER CONNECTED TO 200A BUS WITH 175 DERRATED MAIN BREAKER. ORIGINAL PERMIT APPLIATION ((14041-20000-10828))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59535	14041-20001-12625	6526 N PENFIELD AVE	91367	3	180B113   575	2134039011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.18918	-118.56881	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 4.75kW(1) SolarEdge #SE5000A-US-ZB-U transformerless inverter(19) Canadian Solar #CS6P-250PX pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59536	13041-20001-33169	7001 W HOLLYWOOD BLVD	90028	13	147B181   114	5548003001	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.1017	-118.34196	Delta  9 revisions . Sign Lighting voltage change from 277V to 120VPlan check for power and energy.{{{ Description from building prmit: TENANT IMPROVEMENT OF (E) RETAIL SPACE: (N) STOREFRONT, EXTERIOR CANOPY, PARTITIONS, CEILING SYSTEMS AND MILLWORK.  INCLUDES INTERIOR WALK-IN COOLER AND REFRIGERATION UNITS.  SEE SHELL PERMITS # B12LA13799 & B13LA11074 FOR REFERENCE.}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59537	19041-10000-42444	20271 W VIA URBINO	91326	12	219B113   223	2701062001	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Issued	08/24/2021 12:00:00 AM	ADDRESS	34.29932	-118.57507	(E-PLAN)NEW ROOF-MOUNTED PV1 INSTALLATION FOR AN EXISTING 400 AMPS SERVICE AND INCLUDES 25 MODULES (VBHN330SA17), 25 OPTIMIZERS (P400), AND 1 INVERTER (SE7600H-US),SYSTEM SIZE: 8.25 KW DC; 7.6 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59538	19041-10000-14459	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey, Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	33.98095	-118.40764	FULL PLAN CHECK FOR A PROPOSED OFFICE TENANT IMPROVEMENT TO EXISTING CORE AND SHELL BUILDING. SCOPE OF WORK INCLUDES NEW SUB PANELS TO AN EXISTING DISTRIBUTION SWITCHBOARD, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 48542 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59539	12041-10000-16486	1432 N BEACHWOOD DR	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	34.09679	-118.32107	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR BUILDING 48 TI TO AN (E) OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59540	14041-20001-25861	5254 N BAZA AVE	91364	3	171B105   490	2168021051	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM			PC Approved	09/30/2014 12:00:00 AM	ADDRESS	34.1652	-118.60068	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.8KW INTERCONNECTED WITH MSP.(43) KYOCERA KD255 MODULES(2) SOLAREDGE 5000 AND 3800 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59541	19041-10000-53356	6810 N SEPULVEDA BLVD	91405	6	183B145   699	2220020003	C1-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Issued	12/26/2019 12:00:00 AM	ADDRESS	34.19449	-118.46599	Replacing existing outdoor lights with new LED lights. T-24 ENERGY ONLY.  Affected area: 9964 SFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59542	10041-10001-21035	450 S WESTERN AVE	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.06562	-118.30887	CHANGES TO THE PERMITTED SET OF PLANS : 2 EA 2500A SERVICES REPLACED WITH  1EA 4000A SERVICE; SINGLE LINE REDONE TO ACCOMODATE CHANGE; CHANGES ARE CLOUDED THROUGH OUT THE PLANS SHELL AND CORE ONLYPLAN CHK ONLY((((((((((((Plan check power and energy for new 3-story retail building.Building supplied by two 2500A services. Plan checked under 2007 CEC (2005 NEC). Modification to separate file alarm has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59543	16041-20000-15101	16845 W ARMSTEAD ST	91344	12	213B133   229	2610009016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.28259	-118.49944	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59544	16041-20000-10795	5001 W MELROSE AVE	90038	13	141B193   569	5535017007	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.08365	-118.30951	CHANGE OF USE FROM RETAIL FURNITURE TO RESTAURANT - 1533 SQ FT.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59545	14041-20000-18197	1856 W 68TH ST	90047	8	102B193   685	6016024016	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM			Plans on Hold	08/08/2014 12:00:00 AM	ADDRESS	33.97769	-118.31087	New roof mounted PV system with Enphase Microinverter, Model M215-60-240, total system size 5.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59546	13041-10001-35064	1801 S FIGUEROA ST	90015	9	124-5A205 282	5126002009	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	34.03524	-118.27179	((11/21/2014 - Sup. application for changes to approved set.  Change is location of some walls to accomidate larger conference room and restrooms resulting in changes to lighting and recepticle location.))PLAN CHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION AND REMODELING OF VEHICLE SERVICE FACILITY; PARTS STORAGE AND OFFICES AND THREE LEVELS OF PARKING AND A ROOFTOP PARKING DECKBUILDING PC # 13010-10000-04076	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59547	15041-10000-32526	1950 E 103RD ST	90002	15	091-5A215 138	6066005001	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	33.94298	-118.23783	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59548	12041-20000-17769	12900 N DRONFIELD AVE	91342	7	222B153   133	2509014270	PF-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM			PC Approved	07/30/2012 12:00:00 AM	ADDRESS	34.30524	-118.43367	Install general/emergency lighting at the clorienation room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59549	19041-20000-39173	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359020006	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	03/29/2021 12:00:00 AM	ADDRESS	34.06725	-118.41704	PLAN CHECK FOR POWER AND ENERGY. PROVIDE NEW PANELS AND LOADS TO EXISTING SERVICE. REPLACE EXISTING BRANCH CIRCUITS AND HVAC SYSTEM. PROVIDE NEW OUTLETS AND USB PORTS IN LOCKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59550	11041-10001-06215	458 S HARTFORD AVE 1-66	90017	1	132A207   104	5153023034	CW	Central	Westlake		YES	2091.03	Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM			PC Approved	10/28/2011 12:00:00 AM	ADDRESS	34.05693	-118.26342	Delta D revisions only.  Change fused disconnect from Square D to Cutler-Hammer and change fuse to 175 amperes in compliance with 690.8(B)(1)  for a new 43. KW PV system for an appartment Bldg. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59551	14041-20000-01011	3160 N COLDWATER CANYON AVE	91604	2	159B161   231	2384024011	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Expired	02/10/2016 12:00:00 AM	ADDRESS	34.13134	-118.40812	PV SYSTEM FOR A SINGLE FAMILY DWELLING WITH 3-PHASE WITH 1200A MAIN. TOTAL SYSTEM SIZE 5.25KW. SYSTEM USES ENPHASE M215 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59552	19041-20000-36266	1377 N SERRANO AVE 1st Floor	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.0965	-118.30717	TENANT IMPROVEMENT FOR AN OFFICE IN THE EXISTING OFFICE BUILDING P.C FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59553	19041-10000-06854	528 S SPRING ST	90013	14	129A211   172	5149036010	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.04662	-118.25014	PC T-24 ONLY FOR A TI. AREA SCOPE IS 1163 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59554	15041-20000-22596	12130 W MILLENNIUM GND FLR	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	33.98008	-118.40646	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59555	19041-20000-52196	3715 S MCCLINTOCK AVE	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	07/21/2020 12:00:00 AM		Permit Finaled	03/03/2023 12:00:00 AM	ADDRESS	34.02041	-118.29027	FULL PLAN CHECK FOR POWER AND ENERGY. SERVICE UPGRADE. NEW 2000A SERVICE. SCOPE OF WORK INCLUDES (7) PANELS AND 4800V-480/277V 3P 4W 1500KVA TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59556	17041-20000-40920	14469 W VALLEY VISTA BLVD	91423	4	165A151   124	2266008025	RE9-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.1469	-118.44907	pv1instrall roof mounted pv system sized 5.2kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59557	19041-10000-04084	2802 S ELLENDALE PL	90007	9	123B197  1550	5055012021	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			02/04/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.02947	-118.28859	PV2, PLAN CHECK FOR A NEW ROOF MOUNTED PV SYSTEM INSTALLED IN A MULTI UNIT PROPERTY. TOTAL OF 18 MODULES AND (1) 5.2 KW AC INVERTER. 5.85 KWDC / 5.2KWAC.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59558	11041-20000-22283	17748 W SATICOY ST	91335	3	186B129   263	2120031032	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM			Plans on Hold	10/19/2011 12:00:00 AM	ADDRESS	34.20825	-118.52039	upgrade service to 600 ampsthis is a duplicate permit to 11041-20000-18599claim for refund recomended by elie maalouf on 12/13/11claim # 1125870	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59559	10041-10000-17706	6725 W SUNSET BLVD 4TH FLOOR	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	10/08/2010 12:00:00 AM	ADDRESS	34.09814	-118.33717	TI IN AN EXISTING OFFICE AREA ON THE 4TH FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59560	17041-20000-35059	7636 N HOLLYWOOD WAY	91505	2	186B181    65	2405018021	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.05	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.20977	-118.34836	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (27) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59561	17041-10001-37855	1100 N GLENDALE BLVD	90026	13	139-5A207 131	5404016022	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.07635	-118.26102	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET TO MATCH ON FIELD CONDITIONS. CHANGES INCLUDE GOING FROM XHHW TO THWN-2 BOTH ARE ALUMINUM CONDUCTORS. ALL OTHER CHANGES ARE CLOUDED  UNDER DELTA A. NOTE THE MASTER PERMIT FOR THIS JOB IS 19041-10000-29637. Original plan check: NEW CARPORT MOUNTED 496KW PV SYSTEM WITH 1378 PV PANELS AND 8 CENTRAL INVERTERS AND A BATTERY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59562	10041-10000-13809	5725 W MELROSE AVE	90038	13	141B189   280	5534036019	C2-1D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM			Reviewed by Supervisor	08/19/2010 12:00:00 AM	ADDRESS	34.0836	-118.32537	New DRIVING school building.  Building plan has not been submitted.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59563	18041-10000-17840	914 S LINCOLN BLVD	90291	11	111B145   877	4243004033	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.99864	-118.46184	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59564	16041-20001-45332	1203 S 5TH AVE	90019	10	129B189   652	5081009020	RD1.5-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.04968	-118.32157	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv arrays on SFD and detached guest house. SFD has a central string inverter, and the guest house has microinverters. Interconnect with a 200A MSP.3.8kW string inverter + 2.64kW microinverter system = total ungrounded system size of 6.44kW.(25) 300W pv modules, each with a 300W power optimizer. (11) 300W pv modules, each with an EnPhase M250 microinverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59565	16041-10000-40980	1320 E 7TH ST # 530	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.03598	-118.24041	Plan check for Title 24. T.I to existing two story office building. Total area = 6,150 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59566	15041-10000-03684	7337 W PACIFIC VIEW DR	90068	4	156B177   611	2428016005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM			Reviewed by Supervisor	02/19/2015 12:00:00 AM	ADDRESS	34.12144	-118.35321	Installation of roof mounted solar PV array.  Total system size = 10.2 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59567	14041-10002-16549	450 S WESTERN AVE	90020	10	135B193   649	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			PC Approved	05/18/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	UPDATE PERMITTED PLANS FOR RECENT CHANGES:ADDED LIGHTING CONTROL PANEL  LCPM4; CB FOR HVAC AT LOWER RATE OF 200A; RACK  A INCRESED TO 95KVA AND RACK  B REDUCED TO 122KVA;SWBDS AND DISTBDS LOAD SUMMARIES UPDATED. CHANGES ARE CLOUDED ON THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59568	12041-20000-01755	8943 N OSO AVE	91311	12	195B113    39	2781001016	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.23374	-118.57549	Install new 600Amp service and  swtichboard to replace with fire damage equipment.  All lightings are existing. Plan check for power only.Note: Per applicant, the 600 amp service ONLY supply to warehouse building.  The attached building has it own electrical service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59569	13041-10000-29575	9350 N GLENOAKS BLVD	91352	6	198B173    53	2538011009	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	12/27/2014 12:00:00 AM	ADDRESS	34.23869	-118.37549	FULL PLAN CHECK FOR A SINGLE STORY COMMERCIAL BUILDING. NEW 800A SERVICE. USE OF BUILDING MAINLY CONSIST SEVERAL OFFICES. PLAN CHECK IS POWER AND ENERGY. TOTAL AREA IS ROUGHLY 7720 SQ FT.**SERVICE CHANGED TO 400A DURING PLAN CHECK PHASE**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59570	18041-10000-44447	6336 S BRYNHURST AVE	90043	8	105B185  1029	4006008019	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	33.98181	-118.33365	New Fire Alarm System in a 22 unit Apartment Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59571	19041-20001-05924	20635 W VERCELLI WAY	91326	12	210B109   521	2701051089	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2019 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	ADDRESS	34.27605	-118.58316	changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59572	12041-20001-24929	4136 N COLFAX AVE	91604	2	162B169   106	2368010013	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2012 12:00:00 AM			PC Approved	12/10/2012 12:00:00 AM	ADDRESS	34.14369	-118.38738	As built set of drawings. Reduced to two sets of arrays.Plan check only.Photo voltaic system using Enphase M215 inverters on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59573	17041-10000-18659	1642 S CIMARRON ST	90019	10	126B189   506	5073019022	R2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Issued	09/22/2017 12:00:00 AM	ADDRESS	34.04228	-118.31531	PV1. SCOPE INCLUDES A NEW PV SYSTEM WITH A 5.8KVA POWERWALL BATTERY. TOTAL SYSTEM SIZE IS 3.0KWac.(12)MODULES-LG# LG315N1C-Z4(1)INVERTER-ABB# PVI-OUTD-S-US-Z-A(1)200A SUBPANEL(1)TESLA AC POWERWALL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59574	16041-20001-11719	11500 W SAN VICENTE BLVD	90049	11	129B145   180	4265004***	C1.5-1VL, R4-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			08/31/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.05275	-118.46114	8.31.2016 - Plan check for changes to approved set. Instead of (6) 10kW inverters, installing (4) 15kW inverters. DC system is now >600V (inverter max input voltage is 1000V DC). Module stringing adjusted, total module count has not changed.======Plan check for a PV2 roof-mounted PV system. System size is 60 kWac and consists of (6) inverters, (190) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59575	19041-10000-04753	10300 S COMPTON AVE	90002	15	090A213   193	6065019041	CR-1VL	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	33.94296	-118.24606	Full PC for power and energy. Tenant improvement to (E) medical clinic. Scope includes new lights and receptacles fo examination rooms. Total affected area is 4086 Sq. Ft. B#19016-40000-03102	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59576	18041-20001-07896	10961 W OAK MOUNTAIN PL	91040	7	207B173   509	2528037017	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM			PC Approved	04/09/2018 12:00:00 AM	ADDRESS	34.26198	-118.36931	04-09-2018 Changes to a permitted set of plan. Changes include addition of perfromance meter. Changes has been cluded. plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59577	17041-20000-08810	17731 W CALLE DE PALERMO	90272	11	141B113    19	4431020005	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.07959	-118.57253	PLANCHECK FOR POWER. PLAN CHECK ONLY. NEW 2-STORY SFD/ BASEMENT GAR. 600 AMP SERVICE.BUILDING COMBO PERMIT UNDER # 14010-20000-02285	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59578	16041-10000-06181	13400 W WASHINGTON BLVD #204	90292	11	108B153  1318	4230003077	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	33.99158	-118.44484	"Change of use Tenant space from Retail to ""Burke Williams"" Massage Parlor. PC for T-24 only. Total area 2,050sq.ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59579	15041-10003-12267	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	02/02/16Changes to an approved set of plans. All changes made under delta C. Scope includes removing by-pass switch for time clock and time clock. (((((*** Supplemental to approved set of plan: Connect O.S. to the controlled receptacles, added table of lighting devices model number. **CHANGES TO APPROVED SET OF PLANS. SET CONTROLLED RECEPTACLES TO LOCAL TIME CLOCK. LIGHITNG CONTROLLED THROUGH OCCUPANCY SENSORS, NO ROOM CONTROLLER. NO OTHER CHANGES. POWER DENSITY REMAINS.*PC FOR ENERGY. TI FOR OFFICE TER 3 OF LAX. TOTAL AREA 635 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59580	13041-10000-35324	2049 S CENTURY PARK EAST 10TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLANCHECK AND PERMIT FOR T24 ENERGY ONLY. TENANT IMPROVEMENT. HIGHRISE OFFICES. 10TH FLOOR. 10029 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59581	12041-20000-30093	5601 N DE SOTO AVE MOB II-1st Floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	During verification: Applicant claims that lights are not emergency lights. Plan check for energy only. Retrofit of existing fixtures with LEDs. 290 sqft. MOB II- 1st Floor. Kaiser. NOTE TO INSPECTOR: PLEASE VERIFY UL LISTING OF RETROFIT KIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59582	18041-10000-13256	1025 S ABBOT KINNEY BLVD	90291	11	108B145   928	4239021026	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Approved	04/11/2018 12:00:00 AM	ADDRESS	33.99217	-118.47173	Plan check for energy only. TI to ground floor restaurant. New lighting (incl. emergency). 1,277 sqft.Permit was issued: 17041-30000-05185	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59583	11041-20000-25693	3415 S SEPULVEDA BLVD #210	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM			PC Approved	12/02/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	T24 Energy/emergency for office TI suite #210. Fire / Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59584	14041-20000-13810	14430 W CARLSBAD ST	91342	7	219B149   773	2507011023	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.29439	-118.44737	PV1Install roof-mounted solar array on SFD. System size: 3kW(12) EnPhase M215-60-2LL-S22 microinverters(12) Canadian Solar CS6P 250P pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59585	18041-20000-36006	710 S SANTA FE AVE	90021	14	124-5A217 282	5166002018	(Q)C2-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.03414	-118.22981	Plan check for a PV2 roof-mounted PV system. System size is 10.012 kWdc/9.712 kWac-CEC and consists of (37) micro-inverters, (37) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59586	17041-10000-20580	5727 W LA MIRADA AVE	90038	13	144B189   118	5536001024	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			06/19/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.09387	-118.31452	PC for fire alarm system with 1 FACP, 2 RPS, 1 annunciator and 114 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59587	13041-20000-09530	6151 W PICO BLVD	90035	5	129B173    23	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM			PC Approved	04/12/2013 12:00:00 AM	ADDRESS	34.05337	-118.37542	MODIFICATIONS TO APPROVED SET OF PLANS UNDER PLAN CHECK NUMBER: 13041-10000-01868. ORIGINAL APPLICATION DESCRIPTION: EXISTING BLDG >SHELL. PC FOR ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59588	19041-20000-47715	13263 N WHEELER AVE UNIT 3	91342	7	225B157   706	2512010003	(T)(Q)RD3-1XL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	34.31088	-118.42544	Plan check for PV roof mounted system, PV system size: 2.24 KW DC/2.03 KW AC with 7 modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59589	19041-10000-29396	12414 W EXPOSITION BLVD	90064	11	123B149   857	4259026002	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	09/22/2020 12:00:00 AM	ADDRESS	34.03061	-118.45624	NEW FIRE ALARM SYSTEM WITH 1 FIRE ALARM PANEL, 1 COMMUNICATION PANEL, 3 CONTROL PANELS, 5 COMMUNICATION DEVICES, AND 461 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59590	10041-10000-25268	2000 S AVENUE OF THE STARS 2ND FL	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.05868	-118.41546	TENANT IMPROVEMENT INOFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59591	15041-10000-13038	2037 W ESTES ROAD	90041	14	163-5A223  36	5671005004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Refund in Progress	07/08/2016 12:00:00 AM	ADDRESS	34.1437	-118.21221	PV1, INSTALL 4.59 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME TIE WITH MAIN SERVICE PANEL.(18) MODULES: KYOCERA KU26006XPA(1) INVERTER: SOLAREGE SE3800A-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59592	18041-20000-03481	21700 W OXNARD ST Ste 2070	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.17901	-118.60179	Existing commercial office remodel in highrise building.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59593	15041-20000-24363	11062 N WHITE OAK AVE	91344	12	210B129   393	2712003003	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.27156	-118.51943	Installation of new roof mounted solar PV array.  Total system size = 4.2 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59594	19041-10000-18029	13040 N SAN FERNANDO ROAD	91342	7	222B145    62	2501006024	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.30749	-118.46881	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59595	14041-10004-34558	5100 W WILSHIRE BLVD 1-138	90036	4	132B181    39	5507026001	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			07/11/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.06187	-118.34094	DELTA 6 CHANGES TO THE APPROVED PLANS. CHANGING FEEDERS IN THE COMMOM AREAS FROM COPPER TO ALUMINUM. REDESIGN THE LAYOUT OF ELECTRICAL ROOM. <<<<<Power plan check for new 7 story 138 unit apartment building.  New 5000 A service.>>>>>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59596	16041-30000-39566	1306 N ORANGE DR 1-12	90028	4	144B181   106	5548023037	R3-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.09457	-118.34142	Plan check for new fire alarm system in appartment building. Total fire alarm devices: 70 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59597	14041-10000-05829	1411 S WESTERN AVE	90019	10	129B193  1518	5073010018	C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Closed	03/28/2014 12:00:00 AM	ADDRESS	34.04589	-118.30925	T24,REMOVING EXISTING FIXTURES WITH NEW FLORESCENT LIGHT FIXTURES. TOTAL AREA 6692 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59598	17041-10000-06220	8854 W THRASHER AVE	90069	4	147B169   478	5561025004	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.09898	-118.3856	PC FOR POWER. REMODEL TO (E) 2-STORY SINGLE FAMILY DWELLING.  SERVICE UPGRADE TO 600A 120/240 1PH 3W. B# 14014-10000-02323	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59599	16041-10000-04967	1156 W 1ST ST	90731	15	018B193  1046	7452011039	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	33.74344	-118.3017	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(18)MODULES-SUNIVA OPT335-74-4-100(18)OPTIMIZERS-SOLAR EDGE P400(1)INVERTER-SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59600	17041-20000-23239	510 N HOMEWOOD ROAD	90049	11	135B137   226	4426037010	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	34.0676	-118.48727	PLANCHECK FOR NEW 2 STORY OVER BASEMENT SINGLE FAMLY DWELLING.  600AMP 1 PHASE SERVICE.BUILDING PERMIT # 16010-30000-03606	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59601	12041-20000-06805	12233 W MONTAGUE ST	91331	7	204B165   137	2537003027	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.25634	-118.39959	"Service upgrade from a 400A to 800A.  Install two new panels.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date10/21/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59602	14041-10001-06152	629 E MILFORD ST	90042	14	150A231   112	5312023066	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	34.10626	-118.18228	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(8) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59603	13041-20000-06351	16030 W VENTURA BLVD #200	91436	5	168B141   604	2283011019	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.15598	-118.48247	Change to lighting only, no other work in an existing office space on the 2nd floor of an existing high-rise office building.  Load is less than 400 amps per the applicant.  Load greater than 400 amps (INCLUDING OTHER SUITES) will require full plan review, subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59604	15041-30001-42269	7237 N WHITAKER AVE	91406	6	186B137   378	2226019022	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Issued	10/21/2016 12:00:00 AM	ADDRESS	34.20223	-118.49805	10/21/2016 Changes to an approved set of plans. Number of modules has increased by 2. Standard plan has been updated to reflect changes.*****Previous Work Description*****Addition of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59605	19041-30000-38433	2029 S CENTURY PARK EAST #960	90067	5	132B161   697	4319016029		West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	PC FOR ENERGY ONLT, INTERIOR T.I. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN A PORTION OF THE FLOOR. TOTAL SQ. FT. -1107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59606	17041-10000-41476	360 E 2ND ST #356.5	90012	14	129A215   128	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	PC for T24 only for change of use from restuarant to retail. Installing new lights, receptacles and equipment.B# 17016-30000-23888. Total area is 1234sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59607	11041-20000-26165	7217 N GEYSER AVE 1-5	91335	3	183B121    48	2118025006	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.20173	-118.54275	"PV system on roof of commercial building.Submittal 2 fee is for the payment of expediting the plans.""COMPLY WITH DEPARTMENT ORDER effective date03/31/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59608	16041-30000-22704	3203 S SELBY AVE	90034	5	123B161   989	4254013015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.02927	-118.41712	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.5KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59609	11041-10000-22491	615 S WESTLAKE AVE	90057	1	133-5A203 185	5141001034	C1-2	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM	10/20/2011 12:00:00 AM		Permit Expired	11/13/2013 12:00:00 AM	ADDRESS	34.05852	-118.27408	T-24 lighting plan check for remodeled hotel lobby and entry.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59610	10041-20000-25032	6500 W WILSHIRE BLVD 22nd-24th Floor	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.06371	-118.3703	Plan check T24 Energy for electrical & equipment room on the 24th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59611	19041-10000-21414	7919 W SUNSET BLVD	90046	4	147B177   994	5551018008	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.09821	-118.36239	PC for T24, scope of work is a TI to an exisiting restaurant, total affected area is 1162 sqft. B#: 19016-10000-16498	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59612	16041-20001-13984	9814 N PENFIELD AVE	91311	12	201B113   381	2761015012	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.24844	-118.56945	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. PV addition system size is 6 kWac and consists of (2) inverter, (30) modules, and (1) load center. Total system size is 9 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59613	15041-10000-43911	7313 N RESEDA BLVD	91335	3	186B125   829	2118015010	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.20341	-118.53632	TIT O AN EXISTING COMMERCIAL BUILDING.  REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 5700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59614	17041-10000-11121	10250 W SANTA MONICA BLVD #1707	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PC FOR FIRST TIME TI ""ABERCROMBIE & FITCH""  IN WESTFIELD CENTURY CITY. SUITE 1707, 5,630 SQ.FT"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59615	15041-10000-42312	9189 N DE GARMO AVE	91352	6	198B173   125	2408034042	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	01/24/2022 12:00:00 AM	ADDRESS	34.23604	-118.37603	NEW DISTRIBUTION EQUIPMENT FOR EXISTING LOADS AND FUTURE LOADS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59616	14041-20001-20076	2240 N CHELAN PL	90046	4	153B181   339	5572012006	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			PC Approved	08/22/2014 12:00:00 AM	PIN	34.1123886	-118.34632425	Modifications to approved set.  Change of module model from 280W to 275W version - same manufacturer.  $0 submittal fee is due to Senate Bill SB-1222.  (((pv1install roof mounted pv system sized 5.76kw interconnected with msp.(24) solarworld sw280 modules(24) enphase m250 miroinverters)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59617	12041-20000-08096	145 S FAIRFAX AVE STE 300-3rd Floor	90048	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	PIN	34.07292853	-118.36175524	TI for an office. 2618 conditioned sqft, 3rd story. 4 story commercial building. Plan check for energy and emergency lighting. Suite 300. Building is equipped with emergency generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59618	19041-10000-21104	201 S OCEAN FRONT WALK 1-3	90291	11	109-5A141  65	4286030001	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	05/25/2021 12:00:00 AM	ADDRESS	33.99521	-118.48087	pc for fa system, 1 FACP and 43 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59619	10041-20000-02013	2028 S 5TH AVE	90018	10	126B189  1220	5060026013	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2188.00	Electrical	Electrical	Commercial			02/04/2010 12:00:00 AM			PC Approved	04/12/2010 12:00:00 AM	ADDRESS	34.03818	-118.32231	PV SYSTEM FOR COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59620	17041-20000-08849	11968 W BRENTRIDGE DR	90049	11	141B141   356	4429010056	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	34.08127	-118.47763	New 120/240V 1ph-3w electrical service, distribution, and wiring for remodel of (E) SFD and (N) guesthouse.  2 associated . plancheck onlypermits under building application.building permit applications: main house remodel at 15014-30000-01722 and guesthouse at 16014-20000-00574.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59621	19041-10001-01635	10316-10322 N SEPULVEDA BLVD	91345	7	204B145   250	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.25783	-118.46706	Change to approved set by modifying the floor plan with battery calculation being updated. All changes under delta-2 only.(((NEW FIRE ALARM SYSTEM FOR 1-STORY COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES 1 FA PANEL AND 27 FA DEVICES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59622	16041-10000-36901	911 E 120TH ST	90059	15	084B209   740	6084020041	RD2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	33.92386	-118.25816	Installation of a new fire alarm system  to an apartment 2 story building. (1) Main fire alarm panel, (3) power supplies, (2) Communication panels, (108) Fire alarm Devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59623	16041-10000-12684	1429 W 81ST ST	90047	8	099B193  1053	6034005018	RD3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	33.9656	-118.30134	PV1. INSTALL 5.30 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MODULES: TRINA TSM-265  PDO5 (1) INVERTER: FRONIUS PRIMO 5.0-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59624	18041-20000-39160	5319 N GARDEN GROVE AVE	91356	3	171B125   190	2160014005	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.16733	-118.52876	Plan check for battery storage system connected to existing PV system. Tesla Powerwall 13.2kWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59625	16041-10000-12405	6846 N RESEDA BLVD #C	91335	3	183B125   874	2125010019	[Q]C2-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.19523	-118.53584	Full plan check for a medical/dental office TI. Scope of work includes new lighting and recepticles, no new panels. Total sq.ft 2638.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59626	10041-10000-03200	9060 W PICO BLVD	90035	5	132B169   883	4305007013	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.05505	-118.38929	demolish one of two buildings on site and build 2-story building as addition to remaining building to house the Eliat  Bakery	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59627	13041-10000-33183	250 S ROSSMORE AVE	90004	4	135B185    14	5515013001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.06991	-118.32716	"plan check for power and energy. NEW BUILDING ON CAMPUS OF A PRIVATE GIRLS HS (NEW 129'-4"" x 157'-8""1 story AQUATICS PAVILION BUILDING WITH BASEMENT STORAGE AND ATHLETICS FITNESS ROOMS). methane zone. Also LARGER SURFACE PARKING LOT, A NEW GARDEN AREA, A FULL-SIZE SYNTHETIC TURF SOCCER FIELD, AND 3 NEW TENNIS COURTS. Changes on plan include battery on exit sign to also be fed by inverter and panel FP bus is 125A. Pool panel ACPL installed but loads to be added under separate permit.Fire alarm variance  filed on 8/20/2014"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59628	13041-20000-18387	735 S FIGUEROA ST M2	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM			PC Info Complete	07/31/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	Plan check for power only. Relocation of FIRE PUMP and other loads from one panel to another. All relocated loads within the scope of work for this permit are on the EMERGENCY GENERATOR. 7th and Fig. M2 level.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59629	13041-10001-27681	170 N GLENDALE BLVD	90026	1	135A209   230	5160013013	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.0639	-118.25974	"EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR ARRAY FOR A COMMERCIAL OFFICE BUILDING. TRANSFORMERED INVERTER. SYSTEM SIZE: 6 kW DC, 5.1kW AC. 800AMP SERVICE(24) LUMOS LSX 250 MODULES(1) SMA SUNNY BOY 5000USDESCRIPTION FROM BUILDING : ADD SOLAR PHOTOVALTAIC SYSTEM OF BUILDING BY CREATING A CANOPY (7'-0"" LONG) OVER ENTRANCE"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59630	17041-10000-35227	1149 S BROADWAY 7TH FLR	90015	14	126A209   600	5139019900	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Closed	11/09/2017 12:00:00 AM	ADDRESS	34.03859	-118.26015	PC FOR OFFICE TI ON THE 7TH FLOOR.CREATING NEW OFFICE SPACE. TOTAL AFFECTED AREA 320 SQ.FT.  B# 17016-10000-27196	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59631	18041-10000-39599	1250 S LA BREA AVE	90019	10	129B181   322	5084026045	C2-1	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.05183	-118.34398	NEW STARBUCKS COFFEE SHOP. TOTAL CONNECTED LOAD > 400 AMP. FULL PLAN CHECK FOR POWER AND ENERGY. AREA: 2950 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59632	15041-10000-08447	2748 W 8TH ST 207	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/27/2015 12:00:00 AM	ADDRESS	34.05747	-118.28552	TI 24 FOR AN OFFICE AND RETAIL SPACE, TOTAL AREA 1974-SQ FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59633	13041-10000-35586	9650 N SWINTON AVE	91343	12	201B137   676	2677013037	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.2461	-118.48598	PV1, Install 8.25 kW DC roof-mounted solar array for a  house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (33) modules: Rensola Solar JC250M-24/BB.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59634	18041-20000-45200	6653 W MARYLAND DR	90048	5	135B173   389	5510014011	R1-1-O-RFA	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.06795	-118.37267	Plan check for PV roof mounted system and energy storage system, PV system size: 12.35kW DC, 11.5kW AC with 20 PV Modules, 1 inverter (7.6kW) and 2 LG Chem Battery (9.8kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59635	13041-20000-21451	1701 N WESTRIDGE ROAD	90049	11	135B137   527	4426002013	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM	08/09/2013 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.06408	-118.49378	SERVICE UPGRADE FOR SINGLE FAMILY DWELLING FROM 400A TO 600A. USING 500MCM FOR SERVICE ENTRANCE CONDUCTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59636	16041-10000-40751	1122 W WASHINGTON BLVD	90015	1	126A201   306	5135014021	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Closed	04/23/2018 12:00:00 AM	ADDRESS	34.03877	-118.28233	PC FOR POWER AND ENERGY FOR  NEW 9 STORY PARKING STRUCTURE. PC FOR NEW 1000 A SERVICE. TOTAL AREA IS 170703 SQFT.*NEW KPARKING STRUCTURE (NINE TIERS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59637	14041-20001-34027	7317 N RESEDA BLVD	91335	3	186B125   819	2118015009	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	34.20355	-118.53632	EXPEDITE PER APPLICANT REQUEST[PV2Install a roof-mounted solar array on a commercial building. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system.22  240W pv modules across two strings (11+11).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59638	16041-20000-28722	5716 N WILBUR AVE	91356	3	174B121   201	2156022003	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.17509	-118.54441	Plan check for a PV1 roof-mounted PV system. System size is 5.9 kWac and consists of (21) modules, (21) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59639	17041-10000-19665	13468 W BEACH AVE	90292	11	108B149  1216	4230004032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Issued	06/12/2017 12:00:00 AM	ADDRESS	33.99031	-118.44602	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59640	13041-20001-23802	3217 W ORILLA AVE	90065	14	160-5A217 207	5679024014	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/07/2013 12:00:00 AM	ADDRESS	34.13321	-118.2339	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. 20 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59641	17041-20000-18523	500 S SANTA FE AVE	90013	14	126A217   221	5164004002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM			PC Approved	06/02/2017 12:00:00 AM	ADDRESS	34.04107	-118.23124	PLANCHECK FOR T24 ENERGY. INDOOR AND OUTDOOR LIGHTING FOR CHALMERS SANTA FE. 1825 SQFT INDOOR + 37919 OUTDOOR SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59642	18041-20001-29051	4212 N LANKERSHIM BLVD	91602	4	165B177   892	2423024044	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			06/24/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.14626	-118.36314	6/24/2019changes to an approved set of plans.  changes noted delta 2.  changes to SLD.  new panel new circuits.plan check for power only.  ((((Plan check for power and energy for T.I. of existing restaurant, Service upgrade to 600A. Total area: 4771 sq ft. B#14016-10000-15144))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59643	10041-20000-08533	10452 W BELLAGIO ROAD	90077	5	141B153   212	4362021004	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.0812	-118.43897	17.1KW ROOF MOUNTED PV SOLAR SYSTEM FOR SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59644	17041-20000-34466	14333 W JOY DR	91331	6	198B153  1036	2644027248	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24142	-118.44573	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59645	18041-10000-05900	127 S SAN VICENTE BLVD PLAZA LEV	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.07457	-118.37864	NEW BRANCH CIRCUITS FOR FLOOR-MOUNTED WAY FINDING SIGNS ( LED STRIP) AT THE PLAZA LEVEL  NOTE OCCUPANCY I2.1APPLCANT ASKED FOR PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59646	15041-10003-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM			PC Approved	12/28/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA  30 (CHANGES ARE CLOUDED  ON THE PLANS) REVISIONS TO PERMITTED SET OF PLANS.PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59647	16041-10001-06846	2300 N ALTO OAK DR	90068	4	153B193   438	5587008042	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.11179	-118.31337	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 15.2 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(2) INVERTERS: SOLAREDGE SE7600A(44) MODULES: SUNPREME MAXIMA GXB 300W>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59648	13041-10000-21047	13514 W ORO GRANDE ST	91342	7	228B157   357	2503015021	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.32304	-118.42712	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 5.886KW DC AND 5 KW AC. [MODULE: SUNPOWER # SPR-327NE-WHT-D |||| INVERTER: POWER ONE # PVI-5000-OUTD-US]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59649	14041-10000-09376	970 W 190TH ST SUITE 800&-SUITE 810	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/09/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	33.85812	-118.29302	T24 FOR EXISTING OFFICE SPACE. SCOPE OF WORK ON SUITE 800/810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59650	14041-20001-11794	12140 N BELLANDO CT	91344	12	219B125    92	2601073021	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.29465	-118.52543	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 13.5kW(1) Power-One #Aurora PVI-4.2-OUTD-S-US-Z-A transformerless inverter(1) Power-One #Aurora PVI-6000-OUTD-US-Z-A transformerless inverter(54) Canadian Solar #CS6P-250PX pv modules(2) load centers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59651	11041-20000-21732	3619 N REGAL PL Unit #   1-12	90068	4	159B177   189	2425004014	RD1.5-1	South Valley	Sherman Oaks - Studio City - Toluca Lake	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Apartment			10/11/2011 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.13397	-118.36304	Plan check for new 2-story, 12-unit Apartment Bldg over 1-level of  basement Parking. New 1000A service serving building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59652	17041-10000-41764	123 N MARIPOSA AVE	90004	13	138B197   786	5518005007	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2112.01	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.07354	-118.29954	Remove Outdoor HID fixtures and replace with new LED fixtures. T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59653	19041-10000-41092	4800 N LAUREL CANYON BLVD	91607	2	168B165   505	2355010023	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.15798	-118.39628	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59654	17041-10000-32602	15920 W ALCIMA AVE	90272	11	129B125   235	4420003007	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Expired	03/13/2020 12:00:00 AM	ADDRESS	34.05137	-118.53285	PC for five new energy storage units (Powerwall 2's) and 200A load center in SFD. Installing new 200A main  panel. Total of 67.5kWh system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59655	16041-20000-33659	5631 N COLUMBUS AVE	91411	4	174B145   398	2243005031	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.17323	-118.46419	pv1install roof mounted pv system sizxed 5kw, standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59656	14041-10000-10073	17613 W ROSCOE BLVD	91325	12	192B129   272	2787016007	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.22117	-118.51696	ROOF-MOUNTED 17.28KW DC PV SYSTEM USING M250 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59657	17041-10000-12841	11620 W WILSHIRE BLVD 9th	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	05/27/2017 12:00:00 AM	ADDRESS	34.05021	-118.45963	Title 24 plan check.  T.I. to men's and women's restroom on 9th floor of existing commercial highrise building.  Total area = 394 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59658	12041-10000-06074	3624 N BERRY DR	91604	2	159B173    82	2378028027	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.13573	-118.37904	Plan check for roof mounted 8.085KW M215 Enphase Microinveter photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59659	13041-20003-04124	616 S KENMORE AVE	90005	10	135B197  1102	5502028006	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			06/28/2017 12:00:00 AM			PC Approved	06/28/2017 12:00:00 AM	ADDRESS	34.06289	-118.29646	06/28/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes include the addition of a subpanel, re-circuiting home-runs, and minor lighting changes.5/1/2017changes to an approved set of plans.  changes noted delta 2.  new generator with em lighitng and associated loads in the cooridors and outside podium level only.  general lighitng fixtures changed in common areas.  plan check for energy and power.  2008 title 24. (((((Full plan check for new 57 unit apartment. Fire alarm variance has been filed. METHANE Zone.extention granted to 8/19/15)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59660	16041-20000-24000	19815 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	33.85108	-118.28825	Plan check for a PV2 roof-mounted PV system. System size is 30 kWac and consists of (1) inverter and (76) modules.Building permit #1601-20000-16393	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59661	11041-10000-02945	1 S LMU DR XAVIER HAL	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	06/10/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	TI in an existing office & bathroom. EPC is for T24. (first, second & 3rd floor on Xavier hall)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59662	16041-10000-15549	7536 N GOODLAND AVE	91605	2	186B161   401	2305030020	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.20768	-118.41195	PV 1 NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOFTOP. TOTAL SYSTEM SIZE 8.320 KW. UTILIZING 32 MODULES AND 32 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59663	18041-20000-19260	23931 W JENSEN DR	91304	12	193-5A091 126	2017025066	(T)RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Re-Activate Permit	11/15/2019 12:00:00 AM	ADDRESS	34.22311	-118.64811	PV1.  Install 12.025 kW roof mounted grid tied PV system.  (37) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59664	16041-10000-18324	6300 W WILSHIRE BLVD 1850	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.06319	-118.36591	TI - ON 18TH FLOOR.  ALTERATION TO EXISTING CORRIDOR: ADDING NEW EXIT. INSTALL NEW LIGHTS AND CONTROLLED RECEPTACLES. PC FOR T-24 ONLY. TOTAL AREA: 2,711 SQ. FT.INSTALL LOW VOLTAGE FOR DATA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59665	14041-10000-17706	1645 S ABBOT KINNEY BLVD	90291	11	108B145  1603	4241036038	(T)(Q)CM-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	33.98949	-118.46289	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. EXTERNAL LIGHTS.2251 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59666	14041-10003-05555	3150 W WILSHIRE BLVD SUITE A	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	((((((96/6/14 - CHANGING THE EMERGENCY LIGHTING CIRCUIT TO GENERATOR BACK UP PANEL WEL1-E))))(((5/16/2014- Changed 1 light fixture, it has been clouded. Energy calculations to be verifited)))(((4/7/2014- CHANGES MADE TO APPROVED SET. CHANGES TO LIGHITNG ONLY. PERMIT TO BE PULLED ON THE MASTER APPLICATION)))PLANCHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR STARBUCKS. HIGHRISE. SUITE A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59667	15041-10000-00270	20301 W ANGELINA PL	91364	3	171B113   222	2166036006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2015 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.16531	-118.57714	Installation of new roof mounted solar PV system.  2 inverters with 36 modules (4 strings) with new main service panel.  Total system size = 9 kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59668	19041-20000-51003	3646 S BARRINGTON AVE	90066	11	114B157   476	4234017009	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	07/07/2020 12:00:00 AM	ADDRESS	34.01025	-118.42886	Plan check for PV roof mounted system, PV system size: 2.4KW with 6 AC Moduels connected to existing 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59669	18041-10000-30602	10908 W VANOWEN ST	91605	2	180B173     5	2414022016	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1231.03	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Issued	08/14/2018 12:00:00 AM	ADDRESS	34.19375	-118.36862	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59670	17041-20001-38384	20750 W LASSEN ST	91311	12	201B109   118	2748004034	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.24984	-118.5859	expeditepv1install roof mounted pv system sized 6.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59671	19041-10000-21262	1126 S LOS ANGELES ST Units A&B	90015	14	126A209   292	5145021003	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			PC Approved	06/05/2019 12:00:00 AM	ADDRESS	34.0376	-118.25754	"TENANT IMPROVEMENT TO EXISTING COMMERCIAL SPACE IN UNITS ""A"" & ""B"" WITH THE SAME TENANT IN BOTH UNITS. INSTALING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 19016-10000-16300."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59672	14041-20000-16703	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			Reviewed by Supervisor	07/03/2014 12:00:00 AM	ADDRESS	34.01768	-118.42494	Remodeling the Dining Pavillion for Windward School.  Install new transformer, subpanel, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59673	19041-10000-26382	6565 N FIGUEROA ST	90042	14	156A231   237	5486014041	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.20	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.1219	-118.18472	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59674	12041-10000-31127	2784 W FYLER PL	90065	14	159A219    54	5684019023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	34.13167	-118.22724	PV1 2 STORY HOUSE 17 MODULES [MODULE: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY {M215-60-2LL-S22}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59675	12041-10000-17866	1171 W KIPLING AVE	90041	14	162A229    98	5691011022	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	34.13918	-118.19157	New 8.5kw Transformerless PV System on the rooftop of an existing single family residence	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59676	16041-10000-27508	220 W 5TH ST	90013	14	129A211   286	5149034***	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	03/06/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.04766	-118.25045	Full Plan Check. Change of use and interior TI from storage to day spa. Adding a new feeder to existing service, new lighting, and new power. Total SQft = 3865.(B# 16016-10000-05224)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59677	14041-20001-10953	4939 N LOUISE AVE	91316	5	168B133   106	2290001012	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.15959	-118.51001	EXPEDITE PER APPLICANT REQUEST(((PV1Install roof-mounted solar array on SFD,  interconnect with main panel. System size: 15kW(2) SolarEdge #SE6000A-US-ZB-U transformerless inverters(60) Canadian Solar #CS6P-250PX pv modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59678	13041-10001-06762	441 S BARRINGTON AVE 1-45	90049	11	132B145   113	4401010057	R3-1, RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			03/16/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.06009	-118.46885	pc for power only. CHANGES clouded under DELTA 2. addition of optional standby generator for 14HP sump pump and update to rating of sump pump on E-4. Modified pages E1,2,3,4,8, 20.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59679	16041-20000-02638	10705 W PENROSE ST Unit C	91352	7	195B177   108	2544027007	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Issued	04/04/2016 12:00:00 AM	ADDRESS	34.23241	-118.36447	Plan check for a PV2 roof-mounted PV system. System size is 4.3 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Multi-tenant building (3 tenants) will have a total of (3) PV systems interconnecting to it.Note: Solar clearance shall apply to all (3) tenants.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59680	18041-20000-38699	3418 E 3RD ST	90063	14	124-5A227 317	5179013026	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2039.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.03452	-118.19579	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59681	17041-10000-22147	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.25734	-118.50614	FULL PC TO A  T.I TO  (E) 2ND FLOOR MEDICAL OFFICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN A TREATMENT ROOM WITH NO INVASIVE EQUIPMENT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59682	12041-10000-18050	910 W HARRY BRIDGES BLVD ID GATE	90744	15	027B205   482	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	PIN	33.77039336	-118.27293856	PLAN CHECK POWER FOR NEW ID GATES CANOPY. SITE LOCATED IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59683	18041-10000-12446	164 S HUDSON AVE	90004	4	138B185   380	5515005006	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM			Reviewed by Supervisor	04/20/2018 12:00:00 AM	ADDRESS	34.07199	-118.33325	PLAN CHECK FOR POWER FOR ADDITION OF 2 NEW BACKUP BATTERYS ON SINGLE FAMILY DWELLING WITH EXISTING PV SYSTEM AND SERVICE PANEL RATED AT 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59684	19041-20000-22383	22964 W ARDWICK ST	91364	3	165B097   465	2078017006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.14751	-118.62726	Plan check for a PV1 roof-mounted PV system. System size is 11.7 kWdc/9.9 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (36) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59685	14041-10001-09754	12685 W PIERCE ST	91331	7	210B161   606	2536006010	R1-1	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.27004	-118.40966	Expedited RSES plan check per applicant request.{{PV1, Install 4.75 kw DC roof-mounted solar array on a one-story home, interconnect with main service panel.(1) Transformerless Inverter: SOLAREDGE SE3800A-US-ZB-U(19) CANADIAN SOLAR CS6P-250X}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59686	18041-10000-10271	216 W 45TH ST	90037	9	112-5A203 166	5110005006	R2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	34.00267	-118.27681	PC FOR ROOF MOUNTED PV ON A TRIPLEX. SYSTEM SIZE 1.83KWDC/3.6 KWACSCOPE INCLUDES 6 PANELS AND SINGLE CENTRAL INVERTER ( WITH RSD).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59687	14041-20000-29585	474 E 41ST ST	90011	9	115-5A207 477	5113005011	R2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.00908	-118.26661	pv1install roof mounted pv system sized 4.0kw interconnected with msp.(14) sunpower 327w modules(1) sunnyboy 4000 inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59688	13041-10000-23418	330 S HOPE ST exterior-CPK	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			Corrections Issued	10/11/2013 12:00:00 AM	ADDRESS	34.05319	-118.25252	"PC FOR ENERGY ONLY. SIGN LIGHTING ONSITE. permit to be pulled at EPC counter only.  One exterior sign for CPK.PROPOSED INDIVIDUAL CHANNEL LETTER LUMINATED WALL SIGN, 1'-5.5"" X 22'-9.75"" (33.3 SQ FT) ""CALIFORNIA PIZZA KITCHEN"". REFERENCE APP # 13048-10000-01823, BUILDING APPROVAL IN PENDING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59689	13041-10002-30171	11362 W CHENAULT ST	90049	11	132B145    14	4365010024	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	34.06219	-118.45919	Expedited RSES plan check per applicant request. (((PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 18 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59690	19041-20000-30129	925 W WEST 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.0239	-118.28647	Plan check for Title 2 only for roof compressor and third floor deispenary renovation. Total area: 253 sq ft. B#19014-10000-04044	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59691	19041-10000-11961	1663 S BUTLER AVE	90025	11	126B149   269	4261012903	[Q]PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.04385	-118.45078	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59692	14041-10000-22151	1117 S SAN PEDRO ST	90015	14	124-5A211 199	5145025008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Expired	09/21/2016 12:00:00 AM	ADDRESS	34.03486	-118.25269	permit to be pulled at EPC counter only. plan check for energy only per 2013 standards. emergency lighting installed. Less than 400 A connected load. 5555 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59693	14041-20000-11047	12424 N GLADSTONE AVE	91342	7	219B161   221	2525019065	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.29587	-118.41171	TI. NEW BAKERY. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59694	16041-10000-45278	450 S WESTERN AVE 3RD FLOOR	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.06562	-118.30887	Full Plan check TI, first time tenant for a dining area on new market place, adding new power equipment and lighting. Total area: 5548 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59695	12041-10000-07102	6600 N TOPANGA CANYON BLVD 1084C	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	title 24 and emergency lighting for alteration inside a  retail store at the Topanga canyon Mall	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59696	13041-10000-27678	202 N LARCHMONT BLVD	90004	4	138B189   687	5515025008	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.07478	-118.32343	Lighting and fixture upgrades for retail store.  Title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter. total area to be 900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59697	19041-10001-15758	6036 W SANTA MONICA BLVD	90038	13	144B189   695	5534020036	C2-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.09059	-118.32136	PC (energy only) T-24 for mechanic shop. area of scope (851sf). PERMIT FEES ARE PAID UNDER 19041-40000-15758	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59698	16041-10000-27691	19780 S PACIFIC GATEWAY DR	90502	15	057B197    48	7351034069	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	33.85141	-118.29512	Plan check for T-24 only, TI on an (E) storage room. Install new lights, affected area: 4,840 sq.ft(B# 15014-10000-05616)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59699	10041-20000-20300	21650 W OXNARD ST #1650	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	12/06/2010 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti unit unit # 1650	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59700	10041-10000-06391	3415 S SEPULVEDA BLVD 5th Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			04/08/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	08/23/2010 12:00:00 AM	ADDRESS	34.02055	-118.42347	"Plan check T-24 Energy (general/emergency) lighting on the 5th floor TI. ""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59701	11041-10000-23104	2323 N WORKMAN ST	90031	1	138A221   157	5204011903	PF-1-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM			PC Approved	10/28/2011 12:00:00 AM	ADDRESS	34.07259	-118.21446	Title 24, for one single lite , 32 watts, motion, chane from storage to bath room.  Permit is on application 11041-10000-25845.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59702	18041-10000-33479	2029 S CENTURY PARK EAST # N3160	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Issued	09/11/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN AN EXISTING OFFICE AREA IN SUITE # N3160. T-24 ENERGY ONLY.  2084 SQ FT.BLDG PERMIT 18016-10000-21083	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59703	18041-10000-27252	19800 S VERMONT AVE	90502	15	057B197    54	7351033039	[Q]C4-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	09/06/2018 12:00:00 AM	ADDRESS	33.85122	-118.29031	PLAN CHECK FOR TI FOR SELF-SERVICE, PACKAGED FOOD AND SALES. (561 SQ. FT.). NO COOKING AND DISHWASING. TOTAL AFFECTED AREA = 561 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59704	12041-10001-10643	2970 W OLYMPIC BLVD #301	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	Delta 2 revision to approved plans. Revision to T24 calculations, lighting plan, and power plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59705	13041-20000-11650	10055 N LARWIN AVE 1-6	91311	12	204B097    19	2724003***	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Apartment			05/06/2013 12:00:00 AM	05/07/2013 12:00:00 AM		Permit Finaled	06/01/2013 12:00:00 AM	ADDRESS	34.25533	-118.61746	Plan check for PV system. PV-1. One 2.5kW inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59706	13041-10001-31521	727 S CROCKER ST	90021	14	126A213   309	5146033047	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.03959	-118.24673	pc for energy only. ADDITION OF LIGHTS IN WALKIN COOLER PER INSPECTOR.original description: NEW LIGHTING AND CIRCUITS  IN A REMODELED WAREHOUSE/OFFICE BUILDINGPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59707	19041-10000-48385	6471 N LONGRIDGE AVE	91401	2	180B157   793	2326024018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.18803	-118.4216	PLAN CHECK FOR PV-1 SYSTEM, SYSTEM SIZE IS 2.56KW. SYSTEM INCLUDES 8 MODULES WITH P320 OPTIMIZIRES AND SE3800H-US SOLAR EDGE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59708	18041-10000-43525	9659 N BALBOA BLVD	91325	12	201B133   458	2692002008	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	34.24629	-118.50263	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59709	13041-20000-22868	6725 W SUNSET BLVD #110	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.09814	-118.33717	Existing low-rise office remodel, lights and outlets.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59710	19041-10000-50968	1856 S HI POINT ST	90035	10	126B173   579	5066014014	R1R3-RG	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	09/15/2020 12:00:00 AM	ADDRESS	34.04191	-118.37177	(E-PLAN) NEW PV1 INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 26 MODULES (Q.PEAK DUO BLK-G5/SC 315 W), 26 POWER OPTIMIZERS (P400), 1 CENTRAL INVERTER (SE7600H-US), 2 ENERGY STORAGE SYSTEM, AND 1 PANEL OF 200 AMPS.SYSTEM SIZE: 8.19 KW DC; 7.6 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59711	17041-20001-03792	11249 W CALIFA ST	91601	2	177B173  1395	2337013011	RD2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.03	Electrical	Electrical	Apartment			02/06/2017 12:00:00 AM			PC Approved	02/13/2017 12:00:00 AM	ADDRESS	34.1777	-118.37637	expeditepv1install roof mounted pv system sized 3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59712	13041-10000-35041	11636 W TUXFORD ST	91352	6	192B169   355	2632023049	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.22405	-118.38536	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 16150 SQ FT. TOTAL OF (30) UNITS WILL BE REPLACED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59713	16041-20000-19165	7700 W SUNSET BLVD	90046	4	147B177  1007	5551023023	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.09788	-118.35739	PERMIT FEE $0.00 BY STATE SENATE BILL NO 1222PV2.  Installation of 82.8 kW AC rooftop mounted PV system.  (363) modules with (6) 10.0 kW and (3) 7.6 kW transformerless central inverters and power optimizers.Currently no responsible party signing for plans.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59714	16041-10000-40696	12441 W SATICOY ST	91605	2	186B165   233	2307017017	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Issued	11/30/2016 12:00:00 AM	ADDRESS	34.20862	-118.40443	PV INSTALL 3.360 KW DC ROOF-MOUNTED SOLAR ARRAY  ON A SINGLE FAMIY HOUSE.(12) MICROINVERTERS: ENPHASE ENERGY M250-60-2LL-S22(12) MODULES: CANADIAN SOLAR CS6K-280(1)100A SUBPANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59715	17041-10000-45705	6611 S LA CIENEGA WESTWAY	90056	11	102B173   830	4102002042	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.97962	-118.3711	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59716	14041-20000-09893	7640 N TAMPA AVE	91335	3	186B117    83	2104012066	C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.20967	-118.55333	PLAN CHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR PHARMACY. NOT PATIENT CARE PER APPLICANT. 2208 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59717	13041-20000-05925	4337 E PALMERO DR Pv-1	90065	14	153A219   156	5475005029	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2013 12:00:00 AM	03/11/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.11399	-118.22128	PV-1. Plan check for standard solar plan for single family dwelling. 7kW inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59718	13041-20000-22425	5000 N VAN NUYS BLVD FLR 5	91403	4	171A151   223	2248008087	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.16138	-118.44849	Plan check for energy and emergency lighting. High rise commercial. Fidelity National Title. 5th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59719	15041-20000-38602	6111 S GRAMERCY PL 2nd Floor	90047	8	105B189   843	6001012022	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	33.98411	-118.31358	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,480 sq. ft.Note: Building permit has been issued under 14016-10000-25282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59720	16041-10000-21018	9837 N DE SOTO AVE	91311	12	201B109   134	2746002003	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.2489	-118.58875	PC for T-24 only.  Change of use of (e) retail space to an office. Total area:  56,209 sq.ft (indoor+outdoor). Additional load < 400A.<<Work to include new storefront, exterior facade modifications (no expansion of the building foorprint), new interior non-bearing partition wall, ADA parking re-stripping, repair/replace concrete walkway, and rehabilitation of (e) landscape. B# 16016-30000-10569>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59721	18041-20000-37309	20701 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.29301	-118.58475	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59722	15041-10000-02283	2078 S COMPTON AVE Ste A	90011	9	118-5A213 363	5118025005	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.01834	-118.24455	Plan check for T-24 only. Total area: 8792 SQ. Remove HID fixture and replace with LED fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59723	18041-20001-48533	1990 S BUNDY DR 550	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.03419	-118.45559	PLAN CHECK FOR TITLE 24 ONLY FOR AN OFFICE. PERMIT FEE COVERED UNDER 18041-9000-48533	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59724	16041-10001-01817	300 S SANTA FE AVE #P	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	PC FOR T-24 ONLY. T.I. FOR A YOGURT STORE. PERMIT HAS BEEN PULLED UNDER THE ORIGINAL APPLICATION AS EXPRESS PERMIT FOR 12 RECEPTICLES & 10 LIGHTS.  TOTAL AFFECTED AREA IS 530 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59725	18041-10000-37005	16643 W VANOWEN ST	91406	6	183B137   445	2225009016	R1-1, RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.19404	-118.49571	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59726	12041-10000-01672	330 N LA CIENEGA BLVD	90048	5	138B173   291	5514012006	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			01/24/2012 12:00:00 AM			PC Approved	03/22/2012 12:00:00 AM	ADDRESS	34.07697	-118.3764	Plan check T24 Energy/Emergency lighting using Tailored method calculation with 11990 square feet for BEVMO store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59727	13041-10000-18856	5450 W PICO BLVD SUITE 105	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	34.04862	-118.35714	First-time tenant for a small restaurant/cafe tenant space in a 2-story shopping center.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59728	12041-20000-18035	15260 W VENTURA BLVD 19th fl	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM			PC Approved	08/02/2012 12:00:00 AM	ADDRESS	34.15356	-118.4658	energy plan check 19th fl	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59729	15041-20000-31258	4607 W WAWONA ST	90065	14	160-5A219  28	5683034007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.13621	-118.22526	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59730	19041-10000-50233	11750 W WILSHIRE BLVD	90025	11	129B145  1202	4263008064		West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	05/20/2020 12:00:00 AM		Permit Finaled	08/10/2022 12:00:00 AM	ADDRESS	34.04843	-118.4618	NEW FIRE ALARM IN A HIGH RISE. SCOPE INCLUDES 1 FACP, 1 FIREFIGHTER'S SMOKE SMOKE CONTROL PANEL, 18 POWER SUPPLIES AND 2357 DEVICES WITH ASSOCIATED EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59731	12041-10000-06985	649 W 34TH ST #102	90089	9	120A201   206	5123023024	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	PIN	34.02214675	-118.28186522	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR PSD OFFICE SUITE #102.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59732	14041-10001-08586	5047 N EAGLE ROCK BLVD	90041	14	162A221   160	5686002011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.13832	-118.21463	Permit must be pulled on master application (14041-10000-08586) before changes to an approved set can be made (14041-10001-08586).Supplemental application:  Title 24 plan check only.  Total area = 459 sq. ft. (hardscape)Changes made to outdoor lighting and location of some recepticles.For master application: FULL PLANC CHECK FOR A RESTURANT , TI ASSEMBLY POSITIION. TOTAL AREA 1800 SQ FT.PLAN CHECKER PLEASE VERIFY THE # OF DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59733	18041-20000-24265	5262 W FOUNTAIN AVE	90029	13	144B193    51	5537012002	R3-1	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Expired	10/25/2023 12:00:00 AM	ADDRESS	34.09498	-118.30412	Plan check for PV roof mounted system, system size: 3.8kW with 14 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59734	16041-10000-17662	1446 N NEPTUNE AVE	90744	15	036B205   929	7421027005	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Closed	06/11/2018 12:00:00 AM	ADDRESS	33.79231	-118.26969	INSTALLATION OF NEW ROOF MOUNTED SOLAR PV ARRAY ON EXISTING SINGLE FAMILY DWELLING.  NEW SYSTEM IS 3 KWAC.  TIE IN TO EXISTING 3 KWAC SYSTEM THROUGH NEW 125 A SOLAR ONLY LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59735	14041-20000-34432	350 S GRAND AVE SUITE 1670	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM			PC Info Complete	12/12/2014 12:00:00 AM	PIN	34.05160512	-118.25169569	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS, ADDING NEW CIRCUITS.  WORK TO BE PERFORMED IN SUITE 1670.  TOTAL SQUARE FOOTAGE 3425.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59736	19041-20000-45678	4602 N WHITE OAK PL	91316	5	168B129   613	2182021014	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.15442	-118.52162	PV1. INSTALL 16.12 KW DC ROOF MOUNTED PV SYSTEM WITH (52) MODULES/OPTIMIZERS AND (2) INVERTER (SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59737	14041-20000-23253	320 N CAROLWOOD DR	90077	5	141B157    26	4358006011	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	09/17/2016 12:00:00 AM	ADDRESS	34.0842	-118.42791	DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS. PC FOR POWER NEW SFD. 1200A SERVICE. ABOUT 13,684 SQ FT CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59738	13041-10000-04185	8419 S LOYOLA BLVD	90045	11	096B161   422	4113009030	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	33.96127	-118.41686	photovoltaiv system for single family single story dwelling unit. total system size 2.16kw. using enphase microinverter m215-60-2ll-s22. using solar panel rec 245 pe. 10 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59739	15041-10000-05001	9301 N TAMPA AVE #72	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Title 24 plan check only.  Total area = 780 sq. ft.Replace lighting + relamp, install new circuits for kitchen equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59740	08041-20001-05790	13833 W VENTURA BLVD	91423	4	165B153   518	2271016014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.1487	-118.43426		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59741	13041-20000-14201	1335 E APPLETON WAY	90291	11	114B149  1077	4244020008	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2013 12:00:00 AM	06/25/2013 12:00:00 AM		Permit Expired	07/20/2015 12:00:00 AM	ADDRESS	34.00445	-118.45432	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. PANELS LOCATED ON THE DETACHED GARAGE. 33 PANELS AND 1 INVERTER. TOTAL SYSTEM SIZE 8.25 KWDC. ELECTRICAL PERMIT HAS BEEN PULLED ALREADY UNDER APPLICATION#: 13041-20000-12718. THIS IS A PLAN CHECK ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59742	11041-10000-09826	1908 W MIRAMAR ST 1-38	90057	13	135A205   239	5154020024	R4-1	Central	Westlake			2084.01	Electrical	Electrical	Apartment			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.06299	-118.26982	3 STORY APARTMENT BUILDING.  PER INSPECTOR REQUEST, PLAN CHECK IS FOR TITLE 24 ONLY FOR INSTALLED RECESSED LIGHTING IN THE CORRIDORS..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59743	13041-10000-06937	4422 N BAKMAN AVE	91602	2	165B173   265	2366003007	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Expired	04/15/2015 12:00:00 AM	ADDRESS	34.15101	-118.37777	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 3.024KW. [MICROINVERTER: ENPHASE ENERGY m215-60-2LL-S22] [SOLAR MODULE: REC 245 PE]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59744	18041-10000-00216	5450 W 111TH ST	90045	11	087B173    61	4129037915	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Closed	08/24/2018 12:00:00 AM	ADDRESS	33.93437	-118.37602	PC for temporary power for LAX project. Installing two 800A 480V distribution boards with motors for construction and  portable rock crusher equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59745	14041-10000-09768	3650 W MARTIN LUTHER KING, JR BLVD Space #153	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	TI TO (E) VICTORIA'S SECRET. LESS THAN 400A PER APPLICANT. SPACE #153. EMERGENCY LIGHTING?	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59746	15041-10000-29273	1683 W BLAKE AVE	90031	13	147A213   215	5442009017	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.09562	-118.24178	Energy plan check for factory to a Gym (B occupancy) T.I. Scope includes (2) new panel connecitng through an existing 800-Amp service, new lighting, equipment and recptacles; Total 1325-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59747	12041-10000-06053	17949 W CHATSWORTH ST	91344	12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	09/12/2012 12:00:00 AM	ADDRESS	34.265	-118.52513	TI for new restaurant, new lighting new circuits service and panels are existing, address was entered manually, BOE info need to be submitted when permit is pulled	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59748	17041-10000-10093	11405 N PORTER RANCH DR BLDG A1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			Verifications in Progress	11/22/2017 12:00:00 AM	ADDRESS	34.27695	-118.57088	Plan check for power and energy for outdoor lighing in the mall, newly connected load exceed 400A. Total area: 547,522 sq ft.***************************Applicant provided pre-cut checkPlanchecker to review fees!!!!***************************Building app# 16010-10000-06134	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59749	17041-10000-40314	4210 S DEL REY AVE	90292	11	105B153    19	4230005154	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Public Safety Only			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	33.98723	-118.44379	NEW FIRE WARNING SYSTEM  FOR A 6-STORIES 68 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59750	14041-20001-06769	1276 N BENEDICT CANYON DR	90210	5	144B157   205	4356028003	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.09186	-118.42814	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 28 MODULES. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59751	17041-20000-22233	700 S FLOWER ST 30th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for energy only. TI to corridors, elevator lobby, and restrooms on 30th floor of high rise building. New lighting (incl. emergency) - 1,315sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59752	19041-20000-23924	4137 N TROOST AVE	91604	2	162B169    84	2368010018	RE11-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.14378	-118.38664	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 11.8KW DC/10.5 KW AC. SCOPE OF WORK INCLUDES (33) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS AND A NEW 100A SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59753	13041-20001-05333	2391 N ROSCOMARE ROAD 1-4	90077	5	153B145    35	4378018002	RD2-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Apartment			09/15/2015 12:00:00 AM			PC Approved	09/15/2015 12:00:00 AM	ADDRESS	34.1187	-118.46392	09-15-2015 Change to an approved set of plans. Changes include lighting fixtures layout in the corridor area. {{{{{10 UNITS APARTMENT BUYILDING. Four habitable stories (high-rise residential per energy code). Units 1B and 3B occupy two floors each, all other units are single-story. Fire Alarm Variance has been filed. Not methane zone.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59754	12041-20000-27843	7519 W MULHOLLAND DR	90068	4	156B177   204	2427012020	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	PIN	34.12528205	-118.35865959	PV-1. Plan check for PV system. 400A main service. 5.15kW DC system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59755	13041-10000-28134	6600 N TOPANGA CANYON BLVD SPACE 1001	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	INTERIOR REMODLE; PLAN CHECK FOR TITLE-24 IS FOR LIGHTING 1600SF. SUBMITTAL PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59756	13041-20000-24971	2029 S BUTLER AVE	90025	11	126B149  1088	4261036008	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.03848	-118.4461	PV1 TWO FAMILY DWELLING. TOTAL SYSTEM SIZE 860W USING 4 INVERTERS. MICROINVERTER ENPHASE M215. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59757	16041-20000-37016	17115 W BIRCHER ST	91344	12	213B133   307	2607016042	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.2821	-118.50525	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.88 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59758	14041-10000-11214	4323 N LAURELGROVE AVE	91604	2	165B165   564	2367002039	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Expired	06/03/2016 12:00:00 AM	ADDRESS	34.1492	-118.40097	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER(S): SOLAREDGE  SE3800A-US-ZB-U(14) MODULES: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59759	18041-10000-44618	555 W 5TH ST ste 3750	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	12/24/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR TENANT IMPROVEMENT TO EXISTING OFFICE SUITE. NO CHANGE OF USE. NO STRUCTURAL WORK - TOTAL AFFECTED AREA = 8205 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59760	16041-20000-19747	9301 N TAMPA AVE #177	91324	12	198B117   246	2761037021	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI TO TENANT SPACE TO CREATE STORAGE AREA. NEW LIGHTING. PC FOR T24 ENERGY ONLY. MAIN TENANT SPACE WILL BE UNDER FUTURE PERMITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59761	13041-10000-34763	3201 N LACY ST	90031	1	142-5A221 272	5205002902	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Info Complete	08/01/2014 12:00:00 AM	ADDRESS	34.08349	-118.21854	TEMPORARY POWER FOR PORTABLE BUILDINGS ONLY.  APPLICANT NOTED THE BUILDINGS ARE PRE FABRICATED AND  STATE APPROVED.BUILDING PERMIT # 13014-10000-04943.  RENOVATION/REMODEL OF (E) ANIMAL CARE FACILITY  ABOUT 5000 SQ ADDITION; NEW PARKING DESIGN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59762	19041-20000-52635	4152 N FALLING LEAF DR	91316	5	165B125   353	2184032032	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.14618	-118.52522	INSTALL (1) ENERGY STORAGE BATTERY FOR AN EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59763	14041-10001-05683	10244 N LANGMUIR AVE	91040	7	204B193   764	2559017008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	34.25558	-118.30865	EXPEDITED RSES  PLAN CHECK PER APPLICANT REAUEST.{{PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(23) MODULES: CANADIAN SOLAR CS6P-250PX(1) SOLAREDGE SE6000A-US-ZB-U.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59764	10041-20000-17024	11827 W VENICE BLVD	90066	11	114B157   942	4234016001	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.00775	-118.42664	fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59765	18041-10000-48933	6025 N LAUREL CANYON BLVD	91606	2	177B165   635	2333013023	(Q)C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.18023	-118.39671	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59766	18041-20000-20145	17340 W DEVONSHIRE ST	91325	12	204B129   179	2734028014	A2-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.25733	-118.51256	$0.00 permit fee due to CA Senate Bill 1222. PLAN CHECK FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE = 15.8KVA SYSTEM CONSISTING OF 3 INVERTERS (SOLIS -1P7.6K-4G-US, SOLIS -1P4.6K-4G-US, SOLIS -1P3.6K-4G-US) WITH 66 MODULES (LONGI GREEN ENERGY TECHNOLOGY CO.)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59767	18041-10000-29941	1030 N SWARTHMORE AVE 4-104B	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR FIRST TIME TENANT FOR RETAIL SPACE IN PALISADE VILLAGE MALL FOR POWER  AND ENERGY. SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 435 SQ.FT B# 18016-10000-25062	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59768	10041-10000-17254	5300 N LANKERSHIM BLVD	91601	4	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.16715	-118.37571	"New occupancy in a commercial area.  New ""24Hour Fitness"".  Plan Check is for Power & Energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59769	10041-10000-07703	1333 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			Corrections Issued	06/01/2010 12:00:00 AM	ADDRESS	34.05086	-118.22436	INSTALLATION OF A 2.82 KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59770	17041-10000-08269	6350 W FOOTHILL BLVD	91042	7	198B205   113	2572009018	(Q)C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.24232	-118.26967	Plan check for Title 24 only in existing space. T.I. retail space. Total area: 13,513 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59771	17041-30002-10899	8620 S AIRPORT BLVD	90045	11	096B169   631	4125009020	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	33.95899	-118.38536	11-28-2017 Changes to an approved set of plan. Changes include remove emergency inverter and install unit equipment in the corridor area. Changes has been clouded as delta 6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59772	19041-10000-11414	5555 W MELROSE AVE Edit Bldg.	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	T-24 PC for a TI of an exitsing building (Editorial BLDG), in an office location. scope of work includes 50 new circuits, lighting and receptacles. total affected area is 5897 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59773	19041-10001-22122	9254 N WINNETKA AVE	91311	12	198B113   222	2761001***	(T)(Q)CM-1-MPR, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Apartment			06/11/2019 12:00:00 AM			Not Ready to Issue	12/09/2021 12:00:00 AM	ADDRESS	34.23884	-118.57087	Note: Expedite per Applicant request. Application to collect expedited fees. ((PV2. NEW ROOFTOP SOLAR SYSTEM AT AN APPARTMENT COMPLEX. SYSTEM CONSIST OF 320 MODULES (LG340N1C), 10 INVERTER (FRONIUS SYMO 12.0-3 12KW) CONNECTED TO A 600A SOLAR  PANEL. PANELS MARKED AS EXISTING ARE PRE-APPROVED IN THE ELECTRICAL SYSTEM OF THIS PROJECT, NOT YET INSTALLED. SYSTEM SIZE IS 108.8KWdc AND 120KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59774	18041-20000-26607	13551 W JAVA DR	90210	5	159B157   209	4385002006	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM	07/23/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.1304	-118.42704	Plan check for PV roof mounted system, system size: 3.3kW with 13 pv modules and 1 inverter(3.3kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59775	10041-20000-22883	5757 W WILSHIRE BLVD #300	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.06259	-118.35341	T.I. to existing building.  Install general/emergency lighting in conference 363 and office 326 space of 3rd floor as shown on plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59776	18041-20001-29731	6513 W LAKERIDGE ROAD	90068	4	156B185   114	5577020013	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM			PC Approved	08/12/2018 12:00:00 AM	ADDRESS	34.12335	-118.33771	EXPEDITE PER APPLICANT REQUESTPlan check for PV roof mounted system, system size: 15.2kW with 56 modules and 2 inverters(7.6kW AC)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59777	15041-10000-10657	1200 S CLUB VIEW DR 1-35	90024	5	135B157   112	4327024***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.06748	-118.42481	Energy plan check for owner improvement; scope includes installing new lighting at  the unit 3-north-east corridor. total area is 758-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59778	15041-20001-27969	9180 N SAN FERNANDO ROAD	91352	6	198B169   147	2538008022	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.2363	-118.38969	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 35 kWac and consists of (2) inverters, (110) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59779	17041-10000-05382	8383 N LAUREL CANYON BLVD	91352	6	192B165   248	2633006019	P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	PIN	34.22484333	-118.39821412	"PC for energy only, Title 24. Interior TI and change of use from retail space to restaurant ""Waba Grill"". New lighting and power. Tarea: 2207."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59780	15041-20000-25761	4114 W SUNSET BLVD	90029	13	145-5A201 253	5429002005	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.09324	-118.28152	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the replacement of existing fixtures with new fixtures. Total lighting area = 1,428 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59781	10041-20000-16753	4565 N SHERMAN OAKS AVE	91403	5	168B145   938	2283016033	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	12/21/2010 12:00:00 AM	ADDRESS	34.15373	-118.46929	PLAN CHECK T-24 ENERGY FOR GENERAL LIGHTING OFFICE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59782	11041-20000-03760	6420 W WILSHIRE BLVD 11th Floor	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check T24 Energy/Emergency lighting for Interior tenant improvements on the 11th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59783	14041-20000-15120	24018 W FRIAR ST	91367	3	177B089    91	2033020021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/06/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.18473	-118.64865	PV1Microinverter standard plan. Install microinverter solar array on SFD. System size: 3.67kW.(17) EnPhase 215 microinverters. (17) Sun Module SW270 MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59784	19041-20000-08451	7745 N JELLICO AVE	91325	12	189B129  1124	2202001011	RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.21132	-118.51754	PLAN CHECK FOR NEW 11.2KW DC/9.86KW AC CEC/11.4 KW AC/PV SYSTEM WITH 5KW LG CHEM RESU 10 ESS ON EXISTING SFD. (35) 320W SILFAB PV MODULES WITH P320 OPTIMIZERS, (2) 125A PANEL, AND A SEAUTO TX 5000 TRANSFORMER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59785	18041-10000-21510	236-244 1/2 S VENDOME ST	90057	13	136-5A201 103	5155006016	RD1.5-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.06925	-118.28367	SERVICE UPGRADE TO 600 AMPS IN AN EXISTING APARTMENT BUILDING.REPLACING EXISTING PANELS IN EACH UNIT WITH NEW 100 AMP PANELS AT THE SAME LOCATION. RECONNECT EXISTING CIRCUITS. NO NEW CIRCUIT ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59786	19041-20000-36125	5950 W COLGATE AVE	90036	4	135B181   159	5509005008	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM			PC Info Complete	09/11/2019 12:00:00 AM	ADDRESS	34.06917	-118.35267	Underground pull section for future 800A 208Y/120V 3ph-4w service connection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59787	17041-10001-24431	8500 W BEVERLY BLVD LEVEL 8-ste 860	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	changes to approved set of plans-bulletin # 1 & addendum # 1 . Changes are clouded on the plans and list of changes attached to the plans.FEES FOR ADDED CIRCUITS AND EQUIPMENT ARE ADDED TO FINAL PERIOD ON ORIGINAL APPLICATION  AS PERMIT HAS NOT BEEN OBTAINEDPLAN CHECK ONLY((((((((PC FOR POWER AND ENERGY FOR A RESTAURANT TI ON THE 8TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59788	10041-10000-04528	1520 N SAN PABLO ST	90033	14	135A225    64	5202004041	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM			PC Info Complete	06/23/2010 12:00:00 AM	ADDRESS	34.0627	-118.20276	PLAN CHECK POWER AND ENERGY. TENANT IMPROVEMENT PROJECT OF 15,000 SF  FOR NEW OUTPATIENT SURGERY CENTER, WHICH INCLUDES 8 - OPERATING ROOMS, 22 BEDS FOR RECOVERY AND SUPPORT SPACES. NOT PLAN CHECK FOR OSHPD III	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59789	18041-10000-13594	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM			PC Approved	04/13/2018 12:00:00 AM	ADDRESS	33.78734	-118.29768	INTERIOR TENANT IMPROVEMENT AT THE 3RD FLOOR, BUILDING 'A'. WORK INCLUDES A 96 SQFT. REMODEL OF AN EXISTING STAFF LOUNGE TO A MED PREP ROOM. NO STRUCTURAL ALTERATION TO THE BUILDING ARE PROPOSED. (NON OSHPD).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59790	15041-10000-42628	333 S GRAND AVE 22ND	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.05271	-118.25179	ALTERATIONS IN COORIDOR ON THE 22ND FL  OFFICESPLAN CHK IS FOR TITEL 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59791	15041-10000-32209	5514 W CARLIN ST APT #1	90016	10	123B177  1332	5048027004	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM			Reviewed by Supervisor	10/15/2015 12:00:00 AM	ADDRESS	34.03098	-118.36376	PV1. NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING 2-STORY APARTMENT BUILDING. TOTAL SYSTEM SIZE 2.65KW. SYSTEM TO BE INTERCONNECTED WITH MAIN PANEL. (1) INVERTER-ABB#PVI-3.0-OUTD-S-US-Z-A(10) KYOCERA #KU2656ZPA	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59792	16041-30000-44980	901 N HAVERFORD AVE	90272	11	129B125   574	4412001011	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.04746	-118.52896	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,030 sq. ft. Note: Building application has been created under 16016-30000-29599	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59793	13041-10000-24608	8936 N ODESSA AVE	91343	12	195B137   252	2688009004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.23329	-118.49154	PV1 6.04KWAC 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 28) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59794	10041-10000-24883	1600 N ARGYLE AVE	90028	13	148-5A189 288	5546028014	C4-2D	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.09999	-118.32503	NEW LUMINAIRES IN THE CORRIDOROF THE BASEMENT OF A COMMERCIAL  BLDGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59795	13041-20000-19802	21625 W PRAIRIE ST 1ST FLOOR	91311	12	198B105    91	2746014023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.23919	-118.60115	T24 FOR EXISTING OFFICE SPACE. TOTAL SQRFT 15403.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59796	19041-20000-41067	11881 W TERRA VISTA WAY #121	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW PV DC SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59797	11041-10000-01306	8035 N WEBB AVE	91605	6	189B169    98	2310008003	C2-1VL, M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	06/20/2011 12:00:00 AM	ADDRESS	34.21665	-118.38886	"TI IN AN EXISTING RETAIL STORE IN THE ""MEAT DEPARTMENT"". PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59798	17041-20001-26732	4734 N LOUISE AVE	91316	5	168B133   369	2289010011	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	34.15599	-118.50963	[[12/28/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. ADDITION OF FUSED DISCONNECTS]]]]ENERGY STORAGE SYSTEM 27KWH  ON EXISITNG SOLAR SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59799	12041-20000-17974	8930 N VILLAGE AVE	91352	2	195B177   265	2404001006	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley	YES	1021.01, 1021.02	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.23076	-118.35614	relocate fire alarm panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59800	15041-10000-15780	2030 W 8TH ST	90057	1	132A203   260	5141020017	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.05466	-118.27766	PC FOR POWER AND ENERGY. FIRE DAMAGED BUILDING. RESTURANT. TOTAL AREA 3250 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59801	16041-10001-29628	10319 N NORRIS AVE	91331	7	204B165   115	2537004029	[Q]M1-1-CUGU, [Q]P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.25712	-118.40313	08/31/16Plan check for a lost set of plans. T-24, energy plan check for an existing office space. ((((((Plan check Title 24 only in existing space office T.I. Existing lighting fixture add new receptacles and alter lighing control. Total area: 1,187 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59802	14041-10001-17623	1600 N VINE ST 11th fl	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.1	-118.32647	Supplemental PC only: Change on approved set. Changed on type of lights and qty. Permit under 14041-40000-33494***PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT ON THE 11TH FLOOR. CONFERENCE ROOM AND BATHROOM. 1340 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59803	17041-20002-06492	1540 W FRANCISCO ST	90501	15	057B193    29	7351021033	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM			PC Approved	09/15/2017 12:00:00 AM	ADDRESS	33.84927	-118.30492	Revisions to approved set of plans.  Change of module manufacturer/part no., total number of modules (reduced from 4,104 to 3,456), and equipment layout on roof.   No changes made to AC side of system.  Approval for clouded portions only.  (((Plan check for installation of solar PV system, roof-mounted on commercial building.LADWP Feed-in-Tariff project ~ new 1600A switchboard.960 kW ungrounded system [12 - 80kW inverters]. (4104) 340W PV modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59804	16041-20000-26978	435 W VISTA GLORIOSA DR	90065	1	144A221    23	5452012025	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.09076	-118.21777	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (9) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59805	19041-10000-45562	1637 N DILLON ST	90026	13	144A205   203	5425012015	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM			Reviewed by Supervisor	11/12/2019 12:00:00 AM	ADDRESS	34.08945	-118.27181	[EPLAN] NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 5.04KW DC/ 4.13KW AC, 14 ENPHASE MICROINVERTERS (IQ7PLUS-72), 14 MODULES (POWER XT-360R-PD),  AND ENPHASE AC COMBINER BOX .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59806	11041-10002-27352	648-654 S BROADWAY	90014	14	127-5A211  32	5144002023	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.0454	-118.25294	((((((((  Revision to approved plans. Plan check for power and energy. New branch circuits and equipement added.)))))Plan check power only. New two 800A services serving existing commercial building with new switchboards, panels, emergency generator, ckts and equipment. **Additional fees required, verify all fees when Final	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59807	16041-20000-39962	23130 W VICTORY BLVD	91367	3	180B093   907	2039012020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Issued	11/23/2016 12:00:00 AM	ADDRESS	34.18623	-118.631	PV1.  Install 4.52 kW AC addition to an (E) 8.71 kW DC system.  (15) AC modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59808	19041-10000-40127	1426 N SUMMITRIDGE DR	90210	5	147B157   404	4355007045	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.09627	-118.42005	POWER PLAN CHECK FOR A NEW SINGLE FAMILY HOME WITH A 1,200 AMP, 120/208V, 3PH SERIVICE, WITH PROVISIONS FOR A FUTURE 75KVA GENERATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59809	16041-10000-27815	1318 E 7TH ST	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Issued	08/05/2016 12:00:00 AM	ADDRESS	34.03608	-118.24052	TITLE 24 FOR NEW EXTERIOR LIGHTING FOR TRASH COMPACTOR AREA.AREA INCLUDED (1490SQ. FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59810	10041-20000-09776	915 W WILSHIRE BLVD SUITE 1650	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM			PC Approved	05/24/2010 12:00:00 AM	ADDRESS	34.05069	-118.2599	revisions to 10041-20000-06500Existing permit 10041-10001-06500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59811	12041-10000-02569	8428 W MELROSE PL	90069	5	141B173   505	5528017034	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Info Complete	02/03/2012 12:00:00 AM	ADDRESS	34.08342	-118.37435	TI IN AN EXISTING COFFEE SHOP.  PLAN CHECK FOR T-24 ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59812	16041-10000-25120	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.24253	-118.57768	PC FOR POWER ONLY. TI TO AN EXISTING WAREHOUSE. SCOPE INCLUDES 4 NEW SUBPANELS, NEW MOTOR EQUIPMENT, AND NEW RECEPTACLES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59813	15041-10001-19058	4909 S CRENSHAW BLVD	90043	8	111B185   464	5013017024	[Q]R4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM			PC Approved	01/15/2016 12:00:00 AM	ADDRESS	33.99795	-118.33124	No changes. Lost plans. (((NEW FIRE ALARM SYSTEM FOR AN (E) BUILDING, CHURCH. 35 FIRE ALARM DEVICES AND 1 FIRE ALARM PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59814	18041-20002-17288	17501 W RAYEN ST	91325	12	195B129   200	2768026009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.23232	-118.51605	06-08-2018 Changes to an approved set of plan. Changes include PV point of connection change to loadside connection. All Changes has been clouded. Plan check only.Fees $0 Due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59815	18041-10000-19443	4072 S PUNTA ALTA DR	90008	10	114B177   113	5029031005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.01114	-118.36124	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 14 MODULES (CANADIAN SOLAR CS6K-275P), 16 POWER OPTIMIZERS (SOLAE EDGE P320) AND CENTRAL INVERTER (SOLAR EDGE SE3800H) SYSTEM SIZE IS 3.85KWdc and 3.8KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59816	18041-10000-19855	6260 W SANTA MONICA BLVD	90038	13	144B189   702	5534022031	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.09056	-118.32632	TI IN A RESTAURANT. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59817	16041-10000-31196	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.07125	-118.35662	Title 24 plan check only.  Total area = 1,914 sq. ft.     T.I. to five restroom areas in existing movie theater.  New lighting and GFCI outlets.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59818	19041-10000-39126	17431 W RAYEN ST	91325	12	195B129   204	2768019001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.23231	-118.51485	$0 fee due to AB1414. PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 21.3KWdc/17.4KWac. SCOPE OF WORK IS 60 MODULES (SOLARIA POWER XT-355R-AC) WITH MICROINVERTERS (ENPHASE IQ7PLUS) LEADING TO A 200A LOAD CENTER. PANEL UPGRADE TO BE SEPARTELLY PERMITTED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59819	11041-20000-24240	14950 W OXNARD ST	91411	2	177B145   472	2243022019	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/14/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	01/05/2012 12:00:00 AM	ADDRESS	34.17917	-118.45903	Existing body shop.  Adding new light fixtures to the office and the storage area.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59820	16041-20000-21958	7943 N KEER DR	91335	12	189B125  1017	2102015090	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.21531	-118.53492	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59821	16041-20000-17600	11954 W LOCKRIDGE ROAD	91604	2	156B165    31	2382007002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.12694	-118.3929	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.87 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59822	16041-10000-12056	1317 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	33.78944	-118.24737	ROOF MOUNTED SOLAR SYSTEM ON A 3 UNIT APARTMENT PER SINGLE LINE DIAGRAM. (8) HIS-M250-MG    (8) M215-60-2LL-S22-IG	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59823	11041-10000-06642	10250 W SANTA MONICA BLVD #1000	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGE IN USE FROM RETAIL TO RESTAURANT, TI.  FULL PLAN CHECK.  3 NEW PANELS AND NEW CIRCUITS, PLUS LIGHTING FOR T-24. (The counter restaurant)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59824	19041-10000-44471	21201 W OXNARD ST	91367	3	177B105    67	2149005043	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.17943	-118.59394	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59825	09041-10003-20083	1521 W PICO BLVD 1-56	90015	1	127-5A203 102	5137032023	CM-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Apartment			08/23/2011 12:00:00 AM			PC Info Complete	08/23/2011 12:00:00 AM	ADDRESS	34.04432	-118.27583	New 56 unit, 100% affordable, mixed-use building with one level of underground parking.  Power and emergy.((((((((((((((((((((( Rearranging the section switch gear, load is the same,))))))))))))))))))))))))((((((((((((((((((( Change of two panels from fully rating to series rated. except panel H1 is lestand 10000 AIC therefor no series rating is needed , it is fully rated.   8-23-2011 M.Z EPC))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59826	18041-20001-08274	9733 W MUSTANG WAY	91040	7	204B181   156	2549025031	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM			PC in Progress	03/10/2018 12:00:00 AM	ADDRESS	34.25809	-118.34351	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.5 kWac and consists of (36) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59827	15041-20000-35240	17654 W WELBY WAY	91406	6	180B129   154	2229014011	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.19252	-118.51809	PV1, roof mounted solar array 6.625 kW system(25) modules KU2656ZPA(1) inverter: PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59828	16041-20001-24501	22135 W VENTURA BLVD	91364	3	171B101    43	2169026068	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	09/22/2023 12:00:00 AM	ADDRESS	34.16883	-118.60934	PLANCHECK FOR T24 ENREGY. TENANT UPGRADE RESTAURANT ND BATHROOM. 770 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59829	17041-10002-12470	620 S BROADWAY	90014	14	129A211   228	5144002020	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.04603	-118.25236	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDITION OF RECEPTACLES, CIRCUITS AND CHANGE OF LIGHTING PLAN. ALL CHANGES CLOUDED D. PC for energy and  power. Core and shell only with existing 120/240V, 800A Service. total area 9713 sq ft. B #17016-10000-07254	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59830	14041-10001-24945	8309 W KIRKWOOD DR	90046	4	150A173   459	5556010038	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.10497	-118.37291	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 2.295 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(9) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59831	14041-10000-11925	9841 N AIRPORT BLVD	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	33.94647	-118.38626	T24 only. Highrise office building. Total area 2332 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59832	13041-10000-35014	811 S CARONDELET ST	90057	1	132A201   150	5141025006		Central				2094.01	Electrical	Electrical	Apartment			12/31/2013 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.0564	-118.28261	FULL PLAN CHECK FOR POWER AND ENERGY TO A NEW TOTAL 52-UNIT MULTI-FAMILY AFFORDABLE HOUSING APARTMENT HOUSE BUILDING OVER PARKING GARAGE; 5 STORY + ROOF. PROJECTED LIGHTING AREA IN SCOPE OF WORK IS 21,223 SQ FT ( INDOOR+ OUTDOOR).  building permit: 13010-10000-01359; non-methane zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59833	17041-20002-05743	60 N BEVERLY PARK	90210	4	156B161    81	4386013013	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.12101	-118.4164	10.19.2017 - Plan check for changes to approved set. Update series rating combinations for panels B, P2, and E and downstream panels. Changes clouded delta 2.======10/13/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the series-rating breaker combinations. *****Previous Work Description*****Plan check for power only. Project site is an existing SFD. Project scope is a service upgrade and refeeding certain distribution equipment.Note: Building permit has been issued under 15016-20000-10640	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59834	13041-10000-25381	1539 S BELOIT AVE 1-63	90025	11	129B149   239	4261006014	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Public Safety Only			09/16/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.04774	-118.44842	NEW FIRE WARNING SYSTEM FOR 68 UNITS 4-STORIES APT BUILDING WITH CENTRAL STATION MONITORING; FLOORS ARE MIRROR IMAGE OF EACH OTHER WITH REGARD TO NO OF FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59835	18041-10000-00113	9714 N VARIEL AVE	91311	12	201B105   162	2746003005	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.247	-118.59278	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 5700 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59836	13041-10000-12772	18555 W DEVONSHIRE ST	91326	12	204B125    99	2728028016	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	PIN	34.25817975	-118.53780185	REMODEL OF EXISTING ALBERTSONS MARKET FOR SMART AND FINAL STORE, DEMO AND REPLACE STORE LAYOUT.  EXISTING ELECTRICAL SERVICE AND MAIN SWITCHBOARD.  NEW SUBFED DISTRIBUTION BOARD (800A BUSSING).  RELOCATED TENANT PANELS.  NEW LIGHTING, POWER TO REFRIGERATED HVAC EQUIPMENT.  UNDERGROUND CHECKSTAND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59837	17041-10000-39578	10340-10380 N SEPULVEDA BLVD	91345	7	207B145   772	2649019009	(T)(Q)C2-1, C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.2586	-118.46705	TI TO EX. RESTAURANT AHIPOKI BOWL- NEW LUMINAIRES AND CIRCUITSPLAN CHECK IS FOR TITLE 24ADDRESS IS 10378 N SEPULVEDA BLVD AND TO BE CORRECTED BY OWNER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59838	11041-10000-12547	1840 S CENTURY PARK EAST 9TH	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			Corrections Issued	06/16/2011 12:00:00 AM	ADDRESS	34.06188	-118.41473	TI, TITLE 24, EMERGENCY LIGHTING. 9TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59839	18041-10000-07749	731 S BERENDO ST	90005	10	132B197   320	5094009015	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM			Verifications in Progress	06/04/2018 12:00:00 AM	ADDRESS	34.05883	-118.29429	New rooftop solar system on (1) of the (4) units apartment building. 3.8 kW AC/ 4.8 kW DC system (16) modules with P400, (1) inverter.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59840	15041-20000-25330	23338 W SCHOENBORN ST	91304	12	192B093   387	2005017004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Expired	08/31/2017 12:00:00 AM	ADDRESS	34.2201	-118.636	Plan check for a PV1 roof-mounted PV system. Ssytems size is 7.6 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59841	18041-20000-39023	18325 W LINNET ST	91356	3	171B125   326	2161022027	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.16583	-118.53247	Plan check for a PV1 roof-mounted PV system. System size is 15.4 kWdc/12.1 kWac and consists of (22) micro-inverters, (44) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59842	17041-10001-09019	1748 W CUMBRE DR	90732	15	012B189    24	7560028001	R1-1XL	Harbor	San Pedro	Coastal San Pedro, Northwest San Pedro	YES	2974.00	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	33.72945	-118.31623	PC  FOR changes to approved set under delta 1.This is plan check only. Permit under master. Changes are to reflect changes on the field to the location of the FACP and the Power supply.  A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 89 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59843	15041-20000-00516	9610 N HADDON AVE	91331	7	201B161   825	2624013023	RA-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.24457	-118.41109	NEW LIGHTING FOR EXTERIOR OPEN PARKINGLOT LIGHTING.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 48,920.due to building submittal, plan check in accordance to 2008 building efficiency standards	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59844	13041-20000-00872	350 S GRAND AVE 2600	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	01/14/2013 12:00:00 AM		Issued	01/14/2013 12:00:00 AM	PIN	34.05160512	-118.25169569	Plan check for energy and emergency lighting. suite 2600. 1436sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59845	11041-10000-07312	10380 W WILSHIRE BLVD GRND FLR-1-69	90024	5	135B157   141	4327013***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM			PC Approved	04/12/2011 12:00:00 AM	ADDRESS	34.06719	-118.4277	TENANT IMPROVEMENT.  VALET RESTROOM AND STORAGE REMODEL LOCATED ON THE GROUND FLOOR FOR A HIGH RISE BUILDING.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59846	16041-10007-43434	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.09822	-118.31812	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET.  ALL CHANGES ARE CLOUDED UNDER DELTA 14 & 15. Changes include revising AIC ratings on the single single line diagram, relocating jockey pump on the single line diagram, revising load calculations, and revising floor plans to reflect as built.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59847	16041-10000-17172	11428 W SHERMAN WAY	91605	2	183B169   683	2320001022	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.20103	-118.37983	CHANGE OF USE FROM WAREHOUSE/OFFICE TO RETAIL. NEW COSTCO. NEW ELECTRICAL SYSTEM. FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES ONE NEW 5000A 480/277V 3 PHASE 4 WIRE SERVICE, NEW DISTRIBUTION  PANELS, CIRCUITS AND LIGHTING. PERFORMANCE METHOD IS BEING USED. TOTAL AFFECTED AREA IS 616833 SQ. FT. Building application ref no.: 16016-10000-09606	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59848	15041-10001-00452	2669 N GRIFFIN AVE	90031	1	139-5A223  23	5206005018	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Apartment			01/07/2015 12:00:00 AM			PC Approved	02/09/2015 12:00:00 AM	ADDRESS	34.07847	-118.21203	Expedite Plan check per customer request. (((Plan check for PV System size: 128.21kW(STC) with 1 inverter(100kW) and 440 module and 2 combiner boxs. Service size: 600A, 120/240V 3PH/4W)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59849	18041-10000-01217	11131 W GREENLAWN AVE	90230	11	111B165    55	4215007018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	03/10/2018 12:00:00 AM	ADDRESS	34.0026	-118.40275	NEW ROOFTOP SOLAR SYSTEM, CONSIST OF 30 MODULES WITH INTEGRATED MICROINVERTER ( SPR-X21-335-BLK-D-AC SOLAR MODULES). SCOPE INCLUDES NEW LOAD CENTER (125A), SUNPOWER SOLAR MONITOR AND NEW DERATED SUBPANEL BREAKER. SYSTEM SIZE IS 10.05KWdc AND 9.6KWac CTHE CEC EFFICIENCY VALUE TO THE PLANS (9.035CECAC). NOTE: PERMIT IS PAID UNDER PCIS#18041-10000-01217	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59850	17041-10000-24554	10049 S LAUREL ST 101-202	90002	15	091-5A217 107	6046019920	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	33.9463	-118.23125	POWER PLAN CHECK FOR A  3-UNIT APARTMENT BUILDING. SCOPE INCLUDE A 400A SERVICE AND (4) PANELS. NOTE, THIS BUILDING IS PART OF THE (16) BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59851	11041-20000-05005	13272 W VAN NUYS BLVD	91331	7	207B157   401	2620002024	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	06/24/2011 12:00:00 AM	ADDRESS	34.26567	-118.42237	Install general/emergency lighting for Mini Market.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59852	16041-10003-40602	11120 W CHANDLER BLVD Build. 2	91601	2	171B173   257	2350015036	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM			PC Approved	11/05/2019 12:00:00 AM	ADDRESS	34.168	-118.37317	REVISIONS TO PERMITTED SET OF PLANSREVISED FEEDERS AND UPDATED VOLTAGE DROPS(((((((5 STORY MIXED USE, 106 RESIDENTIAL UNITS WITH 8-TYPICAL. PC FOR POWER AND ENERGY. NEW 2000A SERVICE  AND PRIVATE METER RESIDENTIAL UNITS. . TOTAL AREA INDOOR AND OUTDOOR: 122,538 SQ FT.B# 16010-10000-00103	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59853	16041-10000-41964	6701 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	33.93211	-118.40783	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING CATERING KITCHEN. SCOPE INCLUDES ADDING NEW INTERIOR AND EXTERIOR LIGHTS AND HVAC EQUIPMENT. TOTAL AFFECTED AREA IS 2228 SQ. FT. B#16016-10000-05213	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59854	14041-20001-20539	17183 W OSBORNE ST	91325	12	195B133    93	2690002017	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM			PC Approved	08/05/2014 12:00:00 AM	ADDRESS	34.23351	-118.50845	EXPEDITE FEESPV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 12 KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING 59 MODULES. USING OPWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59855	13041-10000-01003	2465 E 8TH ST	90021	14	123A217   304	5166006018	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Expired	02/11/2015 12:00:00 AM	ADDRESS	34.02971	-118.22776	SERVICE UPGRADE FROM 200 TO 800 AMP IN A COMMERCIAL BUILDING.  RE-FEED 3 EXISTING PANELS. NO NEW LOAD ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59856	14041-10001-31346	6816 N INDEPENDENCE AVE 1-18	91303	3	183B109   872	2138029004	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1349.03	Electrical	Electrical	Apartment			09/04/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.19428	-118.59046	PLANCHECK FOR POWER AND ENERGY. NEW 18-UNIT APARTMENT. 3 FLOORS. [ VERIFY IF FIRE ALARM IS REQUIRED; NO VARIANCE HAS BEEN SUBMITTED]Service change from 1200 amps 3phase 4 wire delta, to a 800 amps 208 wye 120, 3 phase 4 wire.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59857	17041-20000-11936	7425 N KELVIN AVE	91306	3	186B109   615	2113025014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.20541	-118.58638	pv1install roof mounted pv system sized 6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59858	12041-10001-20196	13640 W FOOTHILL BLVD	91342	7	222B157    94	2509014014	(T)(Q)C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.3076	-118.43089	MODIFICATIONS TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 12041-10000-20196. ADDITIONAL DEVICES, UPGRADED FIRE ALARM PANEL. ***********************************************************************************Plan check fire alarm system for 3 story commercial building. Permit for new fire alarm system and new branch circuit to supply fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59859	11041-10000-09612	464 S ROBERTSON BLVD	90048	5	135B169    12	4334003041	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/19/2011 12:00:00 AM	ADDRESS	34.07035	-118.38361	T.I.  EXISTING OFFICE SPACE.  ONE STORY BUILDING.  REPLACING RECEPTACLES AND LIGHTING FIXTURES.  TITLE 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59860	17041-20000-21194	17080 W GOYA ST	91344	12	222B133   343	2602022002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.30446	-118.50392	Plan check for solar pv system, roof-mounted on SFD.New 3kW ungrounded system w/ (9) 290W pv modules, adding to existing 3.6kW ungrounded pv system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59861	14041-20000-13596	4371 S GLENCOE AVE	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	33.9857	-118.43834	PLAN CHECK FOR ENERGY AND POWER.Renovation of existing building to a restuarant (change of use). New 400 amp service. 2660sqft. Regular plan check required due to building occupancy load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59862	15041-10000-19484	13439 W BURBANK BLVD	91401	2	174B157   540	2343015018	(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	Apartment			06/22/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.17234	-118.42584	NEW FIRE ALARM SYSTEM, TOTAL FIRE ALARM DEVICES 88. TWO STORY APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59863	14041-20000-03857	5021 W 21ST ST	90016	10	126B181  1251	5062005005	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.03877	-118.34919	Roof mounted PV system with 4.08KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59864	19041-20000-10439	6824 N AURA AVE	91335	3	183B117   944	2130017002	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.19449	-118.55446	T24 PLAN CEHCK FOR EXISTING LOW RISE COMMERCIAL BUILDING, LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 1083.75SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59865	11041-20001-23488	8750 N SEPULVEDA BLVD	91343	6	195B145   409	2654012007	C2-1	North Valley	Mission Hills - Panorama City - North Hills			1175.20	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	34.22986	-118.46741	Changes to lighting for approved plan under 11041-20000-23488. Plan check for energy and emergency lighting. 4151 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59866	17041-10000-25558	438 S MAIN ST	90013	14	129A211   137	5148009013	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.04716	-118.24785	Energy plan check for a bar T.I. Scope includes new lighting and equipment. Total area is 1776 SQ ft. Note. building permit is under 2014.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59867	15041-20001-34227	4426 N AUCKLAND AVE	91602	4	165B177   238	2424002011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	ADDRESS	34.15115	-118.36025	Expedite per applicant request[[[[[[[[[Plan check for PV roof mounted system. System size: 11.7kW with 46 modules and 46 micro-inverters.]]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59868	13041-10000-32861	500 W WORLD WAY TERMINAL-5-EXIT STAIR	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	pc for energy? permit to be pulled at EPC counter only.LIGHTING WORK FOR TERMINAL 5 OUTDOOR EXIT STAIRS(ADDITIONED TO AN EXISTING BUILDING). CONDUIT-REROUTING TO GO AROUND THE ADDED EXIT STAIR WAYS.PER APPLICANT REQUEST, THE PLAN WAS SUBMITTED AND EXPEDITED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59869	19041-20000-06400	18822 W PARTHENIA ST	91324	12	195B121   389	2785001081	[Q]M1-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	02/23/2021 12:00:00 AM	ADDRESS	34.22808	-118.54338	PV3.  INSTALL 62.835 KW ROOFTOP MOUNTED PV SYSTEM ON EXISTING COMMERCIAL LOWRISE BUILDING. SCOPE OF WORK INCLUDES (213) PV MODULES, (107) SE-P730 OPTIMIZERS, (1) 75KVA XFMR, (2) 30KW AC INVERTERS.$0 PERMIT FEE PER STATE SENATE BILL SB 1222 AND STATE ASSEMBLY BILL AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59870	14041-10005-16201												Electrical	Electrical	Apartment			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM				Delta 15 revisions to permitted set of plansNew circuits BLHN-6 AND BLHS-10 for garage lightingnew luminaires in garage; new luminaires to existing lighting branch circuits;updatelighting relay schedule; adjusted outdoor and indoor Energy Compliance forms	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59871	17041-20001-32634	907 W 17TH ST	90015	1	126A203   200	5135028007	R3-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.03918	-118.27652	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on commercial building.22.8kW ungrounded system [(2) 11.4kW].(81) 350W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59872	17041-20001-34927	213 S FRESNO ST	90063	14	124-5A227  58	5179005037	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.03691	-118.20021	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on 3-unit apartment.3kW ungrounded system. (8) 300W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59873	12041-10000-10792	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	05/13/2013 12:00:00 AM	ADDRESS	34.03396	-118.24117	CORE RENOVATION IN AN EXISTING 4 STORY BUILDING.  CORE & SHELL. EXISTING MAIN SERVIOCE @ 4.8KV FEEDING A NEW 4800 VOLT, 1.5MVA SUBSTATION. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59874	17041-20000-44984	6640 N VAN NUYS BLVD	91405	6	180B149   272	2237001018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.19188	-118.44844	Plan check for power and energy. TI/Change of use to medical clinic/surgical center. New 125kW emergency generator. T24 area - 3,002 sq ft. Not OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59875	19041-10000-07241	5965 S ST ANDREWS PL SHADE-STRUCT.	90047	8	105B193   333	6001013906	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.98626	-118.3116	FULL PC FOR A NEW HOMELESS SHELTER(2 OF 2).  SCOPE INCLUDES NEW BRANCH CIRCUITS FOR A STEEL SHADE STRUCTURE.  B#19010-10000-00857NOTE: PERMIT FOR SERVICE IS COVERED UNDER PCIS#19041-10000-07236	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59876	16041-10000-32695	415 S LE DOUX ROAD 1-19	90048	5	138B173  1050	4334016038	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			09/14/2016 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.07126	-118.37768	Plan check for new appartment building 19 units. Total indoor area: 12,732 sq ft. Total outdoor area: 4,486 sq ftFire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59877	17041-20000-41686	2300 W BEVERLY BLVD	90057	13	136-5A205 272	5154010034	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.06761	-118.27314	Plan check for a PV2 roof-mounted PV system. System size is 30 kWac and consists of (2) inverters, (90) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59878	18041-10000-43289	3730 S TULLER AVE	90034	5	117B161  1079	4252001029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.01376	-118.41894	$0 Permit Fee due to AB1414PLAN CHECK FOR ROOFTOP MOUNTED 13.65 kw DC PV SYSTEM WITH (42) MODULES , (1) AC INVERTER WITH 11.4 KW,  (42) POWER OPTIMIZER P400 WITH 175A CIRCUIT BREAKER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59879	14041-10000-08047	3030 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.01653	-118.21498	PC for power and energy for 1st time tenant. 1story. BLDG# 14016-10-04897:THE EXISTING SHELL BUILDING IS A 'DARK SHELL' AND WAS BUILT TO ALLOW FUTURE TENANT TO OCCUPY.  THE PROPOSED TI WILL BUILD OFFICES AND RESTROOMS, INSTALL ROOF MOUNTED HVAC, INSTALL REFRIGERATION COILES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59880	16041-10000-42560	5956 W OLYMPIC BLVD	90036	4	132B177   728	5086025024	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	06/30/2017 12:00:00 AM		Issued	06/30/2017 12:00:00 AM	ADDRESS	34.05758	-118.36122	FIRE DAMAGE REPAIR. REPLACING LIGHTS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59881	16041-10000-40905	12655-12657 N GLENOAKS BLVD	91342	7	219B153    17	2508027013	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	05/04/2017 12:00:00 AM		Issued	05/04/2017 12:00:00 AM	ADDRESS	34.30002	-118.44028	Title 24 plan check.  T.I. to existing commercial space.  Combine two tenants into one new restaraunt.  New lighting, receptacles, kitchen equipment, and HVAC.  Load < 400 amps.  Total area = 1,710 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59882	14041-20000-12606	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Expired	06/06/2016 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI for commercial office highrise building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59883	15041-20001-34376	200 S LOS ANGELES ST STE A1	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM			PC Approved	03/09/2016 12:00:00 AM	ADDRESS	34.05007	-118.2433	03/09/2016 Changes to an approved set of plans. Changes have been clouded. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****T-24. TI to an existing commercial building (Angelo's Barbershop). (1) New panel of 150 A. PC for energy only. Total Sq Ft = 837	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59884	17041-20001-26151	18574 W MARILLA ST	91324	12	201B121   437	2763033041	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	PIN	34.24674914	-118.53870804	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.7.2kW ungrounded system. (30) EnPhase M250 microinverters.(30) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59885	12041-20000-00406	1422 S BUNDY DR	90025	11	126B145   492	4263029808	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	34.04163	-118.46432	Install four outdoor lightings in the parking lot.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59886	11041-10002-19804	1121 N WATERLOO ST #A	90026	13	141A207   333	5402018***	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			04/12/2012 12:00:00 AM			PC Approved	04/23/2012 12:00:00 AM	ADDRESS	34.07916	-118.26668	Modification to a previously approved set of plans to move the pv feeder from load-side tap to a sub-panel (Load Center).<<<<<Plan check new installation of roof mounted 2.365KW photovoltaic system for unit #A in condo>>> building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59887	08041-10002-26069	7250 W WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2780.00	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	12/08/2010 12:00:00 AM		Permit Finaled	02/01/2011 12:00:00 AM	PIN	33.93790872	-118.42837934	REVISED SET OF PLANS INCLUDING CHANGES IN THE FIELD AND AUDIO/VISUAL RELAYS TO INDICATE TO THE FIRE CREW THAT A CALL IS INCOMINGNew two-story fire station for LAX.  Power and energy.  The site is indicated as a Methane Zone. Verify methane plans on site.  REF.#09042-10000-01109	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59888	16041-20000-15472	1810 S PANDORA AVE	90025	5	132B157   764	4317001005	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.05644	-118.42429	Plan check for a fire alarm system for 4-story, 9-unit apartment building. System consists of (1) FACP, (1) annunciator, and (49) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59889	13041-10000-18704	8125 W MELROSE AVE	90046	5	141B173   389	5528007037	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	34.08387	-118.36681	Retail TI.  Newly connected load < 400 A, title 24 plan check only for new interior lighting on sales floor.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59890	15041-20000-32799	1178 S LORENA ST	90023	14	120A225   285	5190016037	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Issued	10/16/2015 12:00:00 AM	ADDRESS	34.02188	-118.20442	Plan check for Title 24 only. Project site is an existing commercial space. There is no change in area of space or space type. Installed power density is less than 85% of the allowed power density. Project scope is a tenant improvement. Total lighting area = 965 sq. ft.Note: Building permit has been filed under 14016-20000-24059	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59891	18041-10001-02114	6060 W CENTER DR	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	33.97602	-118.39073	PLAN CHECK TO REFLECT FIELD CONDITIONS,  ADDITION OF PUMP AND CONTROL PANEL, PER APPLICANT REQUEST. _____________________PC for T24 only for new lighting in lobby area of office space and outdoor hardscape. Installing new lights and receptacles. Total area is 13353sqft. B# 17016-10000-36281.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59892	17041-20000-04477	2828 N NEWELL ST ste 4	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM			PC Approved	02/10/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	ti to an existing commercial space.  adding new lighting new controls to to new panels.  newly connected load < 400 amps.  plan check for energy and em lighitng only.  total square footage 4002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59893	14041-10001-22925	2132 W LAS COLINAS AVE	90041	14	159A221    81	5685025009	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			Reviewed by Supervisor	09/10/2014 12:00:00 AM	ADDRESS	34.13139	-118.21506	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(6) MODULES: KYOCEERA KD255GX-LFB3(1) INVERTER: POWEER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59894	19041-10000-15796	9500 S MAIN ST	90003	8	093A205    83	6052005001	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Issued	04/30/2019 12:00:00 AM	ADDRESS	33.95003	-118.27371	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTRES T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59895	17041-20000-30479	9330 N WINNETKA AVE	91311	12	198B113   108	2761040027	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.24019	-118.5708	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 229.3 KW DC. FEED IN TARIFF.$0 PERMIT FEE DUE TO STATE SENATE BILL SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59896	10041-10000-00771	1055 W 7TH ST	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			01/15/2010 12:00:00 AM	01/15/2010 12:00:00 AM		Permit Finaled	03/05/2010 12:00:00 AM	ADDRESS	34.0507	-118.26334	T.I, TITLE 24 AND EMERGENCY LIGHTING. HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59897	19041-20000-13868	3026 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59898	17041-10001-42103	2832 S MEDILL PL	90064	5	126B165   975	4308017018	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.03841	-118.40078	Supplemental for PV expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59899	15041-20000-03492	17626 W SUPERIOR ST	91325	12	201B129   276	2755007019	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.24661	-118.51877	PV1CENTRAL TRANSFORMERLESS STANDARD PLAN SYSTEM SIZE 10.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59900	14041-10000-33573	8631 W 3RD ST STE 1140	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.07373	-118.38036	plan check for power and energy. Full plan check for medical office T.I. Net reduction in load. Changes on plan include redundant grounding via MC cable and T24 wattage update.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59901	16041-10000-12930	925 N LA BREA AVE 101	90046	5	144B181   708	5531016020	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.08803	-118.34436	Plan check for power and energy. Non High-rise. New load greater than 400A. INTERIOR TENANT IMPROVEMENT OF 3 FULL FLOORS OF A 6 STORY BUILDING, INCLUDING INTERIOR NON LOAD BEARING PARTITIONS, PARTIAL CEILINGS, LIGHTING AND FINISHES ALL 3 FLOORS TO BE SINGLE TENANT OCCUPANCY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59902	11041-20000-26558	7737 N LOMA VERDE AVE	91304	3	189B109   976	2109021013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2011 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	02/10/2012 12:00:00 AM	ADDRESS	34.21104	-118.58976	New 1.38 KW roof mounted PV system for single family residence.  Applicant is using the M215.  A variance has been filed to be able to use the microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59903	15041-20000-43513	12113 N LOUISE AVE	91344	12	216B129    76	2606027059	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.29149	-118.51311	PV1 roof mounted installation to a single family home. Inverter: 10kw, 40 solar modules. total system size 10.0kWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59904	17041-10000-17836	1500 N EL CENTRO AVE	90028	13	148-5A189 331	5546026***	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.09917	-118.32359	TI on the 4th floor of existing 6-level office builidng to include new partitions and finishes.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59905	19041-20000-03979	602 W PARK ROW	90012	1	139-5A217  71	5415030015	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural	Yes	2060.10	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Issued	02/01/2019 12:00:00 AM	ADDRESS	34.07672	-118.2314	Plan check for PV roof mounted system, PV system size: 4.32KW with 12 AC Modules. connected to 400A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59906	14041-10000-20560	6600 N TOPANGA CANYON BLVD #2108	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	permit to be pulled at EPC counter only. Plan check for energy only  per 2013 standards. AT&T dealer store. BLDG#14016.10.15038 : new non-structural wall, new gypsum board ceiling with new finishes and  millwork  at  suite  2108.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59907	15041-10000-39684	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	FULL PC, TI TO A RETAIL SPACE, MACYS, AT THREE LEVELS B, 1, AND 2. SCOPE OF WORK INCLUDES NEW LIGHITNG AND CIRCUIT LOAD. ADDING NEW PANELS TO AN EXISTING SWITCHGEAR. TOTAL SQ. FT. 152,053.  **F.A. variance filed on 4/6/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59908	19041-20000-15562	13919 W VICTORY BLVD	91401	2	180B153  1066	2238024039	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	07/16/2021 12:00:00 AM	ADDRESS	34.18684	-118.43635	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW 2-STORY APARTMENT BLDG WITH 1 LEVEL OF UNDERGROUND PARKING. SCOPE OF WORK INCLUDES (61) FIRE ALARM DEVICES AND A FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59909	14041-20001-26047	949 E 31ST ST	90011	9	117A209   111	5114022013	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/22/2014 12:00:00 AM	ADDRESS	34.01546	-118.25833	PC FOR T24 ENERGY ONLY. PERMIT ISSUED UNDER ORIGINAL APPLICATION. PC ONLY.PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59910	16041-10000-19581	10636 N BOTHWELL ROAD	91326	12	207B117   277	2708013014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.26373	-118.56122	Pv1, New roof mounted solar system. (35) AC modules and (1) 100A, load center. Total system size is 11.4 KW.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59911	12041-10000-00956	1039 W FLORENCE AVE	90044	8	102B197  1118	6014036019	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM			PC Approved	01/26/2012 12:00:00 AM	ADDRESS	33.97478	-118.29326	Change of lighting only to an existing Medical Office, per applicant.  Stand alone building, with existing 200A service.  Office only, NO Medical Equipment per applicant.  PLAN CHECK is for T-24 only, with Emergency lighting.  Full plan check may be required subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59912	18041-20003-14334	6822 W PARSONS TR	91042	7	207B201    23	2553014002	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	9800.26	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.26631	-118.28268	Revisions to approved set.  Field revisions - trenched conductor size changed, auxiliary grounding electrode detail modified, and fused disconnect to replace non-fused.  (((06/19/2018 Changes to an approved set of plans. PV system strings have been revised. Equipment count has remained the same. Note: $0.00 permit fee due to CA Senate Bill 1222PC for 12.42kW(ac)/17.55kW(dc) system for SFD. Installing 54 modules with microinverters with combiner box.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59913	19041-10000-37605	10250 W SANTA MONICA BLVD S1830	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for energy only, T.I. to existing retail store to reconfigure for new storage area. scope of work includes new lighting and receptacles. Total Sq. ft. 528.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59914	17041-10000-03262	1122 W 6TH ST STE 101	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.05419	-118.26301	Plan check for power and energy First Time Tenant Chaipotle in mix use appartment building. Total area: 3,400 sq ftB#17016-10000-02256	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59915	14041-10000-28500	3147 W SAN FERNANDO ROAD	90065	13	154-5A213 187	5458007009	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.11607	-118.24685	Energy plan check in a partial area of  a retail T.I. building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59916	18041-10001-03749	10250 W SANTA MONICA BLVD #2510-LV L2	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM			PC Approved	05/31/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"DELTA 4 CHANGES TO PERMITTED SET OF PLANS- UPDATED CURRENT LIMTER TO 4.0A ON SHEETS E-100 & EN-101 AND MODIFIED ELECTRIC PLAN SHEET E-100ALL CHANGES ARE CLOUDED AND MARKED(((((((((FULL PLAN CHECL FOR RETAIL SPACE ""ADIDAS"". (3) NEW PANELS AND (1) 75KVA XFRM. TOTAL AREA: 8,077 SQ.FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59917	16041-30000-12711	3006 N NORTH MAIN ST	90031	1	135A223    24	5210024007	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.06582	-118.20988	Plan check for Title 24 energy only. Medical laboratory no patient will be at the laboratory. Total area: 3,973 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59918	16041-30000-41892	11400 W CULVER BLVD	90230	11	111B161   400	4217015002	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	PIN	34.00072849	-118.41264563	Plan check for Fire alarm system for new appartment building 21 units. Total Fire alarm devices: 51 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59919	18041-10000-14610	3260 S CLUB DR	90064	5	123B165   698	4316030025	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.0328	-118.40233	No Permit Fee Due to Senet Bill # AB1414PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND THREE ENERGY STORAGE SYSTEMS (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. , CONISIT OF 49 MODULES(#SC325) AND THREE CENTRAL INVERTERS (DELTA SOLIVIA 5.2-5.2-3.8) . SYSTEM SIZE IS 14.2KWac AND 15.925KWdc.SCOPE INCLUDES TWO NEW LOAD CENTERA (200A & 125A) AND A SUBPANEL(200A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59920	13041-10001-31751	101-109 S LA BREA AVE BUILDING A-LEVEL 1	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Closed	12/24/2013 12:00:00 AM	ADDRESS	34.07338	-118.34425	changes to approved set of plans:  addition of two detectors and 1 notification.METHANE GAS CONTROL SYSTEM; CHANGE OF SYSTEM FROM SIERRA GAS DETECTION TO INTEC GAS DETECTION SYSTEM.  TENANT IMPROVEMENT TO AN EXIASTING COMMERCIAL BUILDING. METHANE ZONE DESIGN LEVEL 5.EXISTING ELECTRICAL PERMIT UNDER: 13041-10000-14984 FOR SIERRA GAS DETECTION SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59921	14041-10001-08594	1288 N ANGELO DR	90077	5	144B153   281	4357014006	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.09339	-118.43608	installing a11.232kw PV system on the roof of SFD ;MICROINVERTERS ARE USED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59922	13041-10001-26834	2030 S CENTURY PARK WEST	90025	5	132B161   715	4319004138	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			Corrections Issued	11/13/2013 12:00:00 AM	PIN	34.05620922	-118.41664926	"""EXPEDITED PER APPLICANTS REQUEST""PV2.  NEW ROOF MOUNTED PHOTOVOLTAIC SYSTEM. SYSTEM SIZE 93,600 kW DC. 82,469 AC. TRANSFORMER LESS INVERTER. (312) ASTRONERGY CHSM6612P 300W MODULES(4) SNA SUNNY TRIPOWER 20000TL-US 20KW (480V)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59923	15041-10000-25580	23401 W FRIAR ST	91367	3	180B093   933	2035018032	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM			Reviewed by Supervisor	08/17/2015 12:00:00 AM	ADDRESS	34.18567	-118.63694	INSTALLMENT OF 10.2 KW DC ROOF MOUNTED SOLAR SYSTEM FOR A SINGLE FAMILY HOME. (40) MODULES YIMGLIENERGY YL255P-29B. (1) INVERTER: SOLAR EDGE SE7600A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59924	16041-20001-37093	9827 N CANBY AVE	91325	12	201B125   145	2764001007	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM			PC Approved	10/28/2016 12:00:00 AM	ADDRESS	34.24922	-118.53468	Expedite per applicant request.Plan check for a Pv1 roof-mounted PV system. System size is 10.3 kWac and consists of (41) modules, (41) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59925	13041-10000-17920	2930 E WASHINGTON BLVD	90023	14	118-5A221 146	5169025032	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.01701	-118.21639	PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR OUTDOOR LIGHTING. PARKING LOT. 38,589 SF. 8 parking lot lights 480V on 30' (overall height ) poles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59926	14041-20001-01951	7843 S AIRLANE AVE	90045	11	099B169   621	4106024009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	33.96777	-118.39034	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 20 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59927	12041-10000-04485	2000 S AVENUE OF THE STARS 1st Floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check T24 Energy/Emergency lighting for banking center on 1st floor of an high rise building. Permit for replacing existing fixtures in the finance/banking area and office/conference room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59928	17041-10000-12200	1875 S CENTURY PARK EAST #930	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Info Complete	04/14/2017 12:00:00 AM	ADDRESS	34.06115	-118.41457	Plan  check for Titel 24 only in existing space T.I. in office. Total area: 1,114 sq ft.B#16016-10000-17307	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59929	19041-10001-51564	19747 W GREENBRIAR DR	91356	3	165B117   389	2178005059	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			PC Approved	01/09/2020 12:00:00 AM	ADDRESS	34.14591	-118.56311	***Expedite Fees***PV PLAN CONSISTING OF 197 (TESLA #SR60TI) MODULES, 3 CENTAL INVERTERS ( DELTA SOLIVIA), CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS  11.15 KW DC &14.2KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59930	14041-10000-06158	2327 S GLYNDON AVE	90291	11	111B149  1380	4242031011	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	33.99648	-118.44991	PV1,INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY SINGLE FAMILY DWELLING, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000-US-ZB-U(23) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59931	17041-10000-33731	7541 N VARIEL AVE	91303	3	186B105   220	2112005009	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.20761	-118.59301	New rooftop solar system on a SFD, 4.4 kW DC with (1) inverter (16) modules with (16) power optmizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59932	10041-20000-05776	5700 N CANOGA AVE 300	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM			Not Ready to Issue	04/27/2010 12:00:00 AM	ADDRESS	34.17365	-118.59715	OFFICE TI lighting and power. This plan check is for title 24 energy only.     Existing permit #10041-20000-07705.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59933	16041-20000-19959	17206 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.20827	-118.50782	PLANCHECK FOR POWER AND ENERGY PER APPLICANTS REQUEST. CHANGE OF USE FROM BANK TO RESTAURANT.  BUILDING P# 16016-20000-06236  T. I. to convert (E)47' x 60' irreg. shaped portion of bank into restaurant(1792 S.F. with max. 49 seats).  Restripe (E)poriton of parking lot to add 14 additional stalls.  SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59934	17041-10001-15056	1431 E 22ND ST	90011	9	118-5A211 101	5119028009	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM			Reviewed by Supervisor	05/19/2017 12:00:00 AM	ADDRESS	34.01977	-118.24947	EXPDITE FEEPC FOR ROOF MOUNTED PV SYSTEM SIZE 10.4 KWAC SYSTEM INCLUDE TWO  5.2KW INVERTERS WITH 38 MOUDULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59935	13041-10001-32342	18425 W ARMINTA ST	91335	12	189B125   436	2102015***	(Q)RD6-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.21394	-118.53464	Expedited RSES plan check per applicant request.(((PV1, Install 6.615 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE6000A-US. 27 modules Yingli YL245-29b.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59936	18041-20000-46492	2519 N ZORADA DR	90046	4	153B177   210	5569021031	RE11-1-HCR	South Valley	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.11721	-118.36124	PV1.  Install 11.78 kW DC roof mounted grid tied PV system.  (38) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59937	19041-20000-01414	8922 S READING AVE 1-30	90045	11	096B169  1050	4125017002	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM			Verifications in Progress	09/09/2020 12:00:00 AM	ADDRESS	33.9559	-118.38144	Plan check for power and energy for 7 story 30 unit multi-family building 2000A Service 208/120voltTotal area:  47,593 sq ft. B#18010-200000-05591	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59938	18041-20001-02358	9336 W WAYSIDE DR	91040	7	207B185   522	2549017009	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM			PC Approved	02/07/2018 12:00:00 AM	ADDRESS	34.26102	-118.33471	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (35) modules. System is interconnecting with a 400-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59939	19041-10000-12440	6033 W CENTURY BLVD 10th floor	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			PC Approved	04/05/2019 12:00:00 AM	ADDRESS	33.94572	-118.38954	PLAN CHECK FOR TITLE 24 ONLY T.I FOR CORRIDORS AND ELEVATOR LOBBY. INSPECTION FEES HAVE BEEN PAID UNDER ONLINE PERMIT 19041-9000-01021	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59940	18041-10000-24912	950 W 190TH ST 2nd Floor	90502	15	060B197   582	7351031020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	33.85814	-118.29219	TENANT IMPROVEMENT WORK, ADDING 2 NEW OFFICES ON THE 2ND FLOOR. T-24 ENERGY ONLY.Building Permit # 18016-10000-09653	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59941	19041-10000-06363	2439 N RIVERSIDE PL	90039	13	148-5A211 150	5440026008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Issued	02/21/2019 12:00:00 AM	ADDRESS	34.10129	-118.25338	PC FOR ROOR MOUNTED PV ON SFD (ROOF SHINGLES). SCOPE INCLUDES 308 SHINGLES WITH CENTRAL INVERTER. (ESS UNDER SUPP.  APP). TOTAL SYSTEM SIZE 7.6KWAC /7.315 KWDC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59942	19041-20000-37906	5913 W WILLOUGHBY AVE	90038	13	144B189   997	5534028016	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.08722	-118.32489	PV2. INSTALL 3.330 KW DC SOLAR SYSTEM WITH (9) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3000H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59943	18041-10000-07631	140 W ANAHEIM ST Unit A	90744	15	030B205   411	7423002042	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	33.77972	-118.26333	PC for T24 only for change of use from retail to restuarant. Installing new lights, receptacles and equipment. B# 17016-40000-35991.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59944	12041-20000-25307	8710 N ENCINO AVE	91325	12	195B129   422	2768015014	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.22897	-118.51557	Change of contractor. New Plans. Plan check over the counter per previous agreement. Previous PCIS number is 12041-20000-21000.Zoning cleared on 12041-20000-21000.Plan check for PV system. SFD. 11.04kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59945	11041-10000-08556	707 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	33.78001	-118.24199	8,997 SQ. FT. PRE-ENGINEERED METAL BUILDING.  1 STORY LOCOMOTIVE SERVICE AREA OVER 2 TRACKS, STORAGE ROOM, RESTROOMS, BREAK ROOM, OFFICE, SHOP, ELECTRICAL ROOM AND PARTS AND STORAGE ROOM.  FULL PLAN CHECK TO INCLUDE NEW PHOTO VOLTAIC SYSTEM AND  FIRE ALARM.  EVERYTHING IS NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59946	17041-10000-02615	5850 S MCCONNELL AVE	90094	11	102B161  1270	4211037026	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/26/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.9745	-118.41706	Plan check for new Fire alarm system on New 4 story 6 units Condo. Total Fire alarm devices: 46 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59947	16041-10000-10152	9101 N RESEDA BLVD	91324	12	198B125   262	2763034003	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Issued	06/17/2016 12:00:00 AM	ADDRESS	34.23593	-118.53628	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS 2352 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59948	14041-20000-26242	10965 W WEYBURN AVE	90024	5	135B149   594	4363017009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.06239	-118.44756	TI TO AN EXISTING ONE STORY RESTAURANT.  PLAN CHECK FOR TITLE 24 ENERGY ONLY.  NEW EQUIPMENT AND CIRCUITS INSTALLED.  2218SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59949	10041-20000-22895	6200 W FRANKLIN AVE	90028	4	150A189   193	5586024400	R4-2	Central	Hollywood	Hollywood United		1895.00, 1903.01	Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	12/06/2010 12:00:00 AM	ADDRESS	34.10503	-118.32418	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59950	12041-10000-20725	7003 N FIGUEROA ST	90042	14	159A229   267	5480010028	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	12/05/2012 12:00:00 AM		Permit Expired	12/30/2014 12:00:00 AM	ADDRESS	34.12936	-118.18816	This is a 30 KW PV system roof mounted,  two story bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59951	18041-10000-30382	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM			PC Approved	08/10/2018 12:00:00 AM	ADDRESS	34.09918	-118.32644	INSTALL 12' X 25' (300 S/F) EXTERNALLY ILLUM. SIGN TO THE NORTH SIDE OF AN EXISTING  APARTMENT BUILDING.SIGN PERMIT: 17048-10000-02693	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59952	17041-20000-06586	14631 W LIMEDALE ST	91402	6	201B149   679	2650023001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.24462	-118.45151	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (32) micro-inverters and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59953	14041-10000-11534	8222 N TYRONE AVE	91402	6	192B153   924	2212016018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.22042	-118.44412	PV1 3.25KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(13)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59954	16041-10002-29143												Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM				REVISIONS TO PERMITTED SET OF PLANS : RELOCATE COOLER AND FREEZER IN THE SAME ROOM; NEW CIRCUIT FOR SF-1PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59955	19041-20000-04442	5711 N SEPULVEDA BLVD	91411	4	174B145   884	2260010017	CM-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.17435	-118.4665	Plan check for Title 24 only existing Target restroom retrofit lighting fixtures in restroom 1st and 2nd floor. Total area: 1068 sq ft. B#19016-20000-03346	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59956	17041-20000-43081	16441 W FLANDERS ST	91344	12	213B137   508	2610028015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.28014	-118.49047	PV1.  Install 6.6 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59957	17041-20001-29152	7243 N CEDAR ROAD	91405	2	186B153   937	2217032106	(T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.20259	-118.44077	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 3 kWac and consists of (1) inverter, (6) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59958	19041-10000-48220	445 S FIGUEROA ST 15TH FL	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	Energy plan check for a T.I located on the 15th floor of a commercial building. Scope inlcudes new lighting and equiumpent with a total area of 14,135-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59959	17041-20000-12471	12200 W OLYMPIC BLVD STE 400	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.03195	-118.45506	"PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT ON THE 4TH FLOOR OF EXISTING COMMERCIAL BUILDING "" RIOT GAMES"". NEWLY CONNECTED LOAD EXCEEDS 400 AMPS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59960	15041-20000-08949	445 S FIGUEROA ST 19th Floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for T-24 only for T.I. common area renovation. Total area: 9070 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59961	17041-20000-45312	318 S MEDIO DR	90049	11	129B141   136	4405038019	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM			Reviewed by Supervisor	01/12/2018 12:00:00 AM	ADDRESS	34.05276	-118.48032	New SFD with basement and attached garage.  400A 240/120V single phase service.  Plan check for power.  Building permit under 16010-30000-05746	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59962	16041-20002-30241	19538 W BLACKHAWK ST	91326	12	204B117   174	2708004003	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.25764	-118.55931	[[ 1/8/17  CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. CHANGING INVERTER SYSTEM TO SUNVERGE SIS 6848 ]]]Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 7 kWac and consists of (28) modules, (28) micro-inverters, (3) load centers, and (1) battery system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59963	18041-20001-48665	9825 N WISH AVE pv1	91325	12	201B133   220	2692014009	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2018 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.24918	-118.508	expeditepv1install roof mounted pv system sized 16KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59964	17041-10000-01884	11308 W PENROSE ST PV	91352	6	192B173   238	2632006012	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.22442	-118.37769	$0 permit fee due to senate bill#12222PV roof mounted solar system installation to a commercial building. (25) Central inverters for a total system size of 860 KW system,  (3244) Solar modules, (2) 800 Amps load center, new 1600 amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59965	13041-10000-09127	4627 N MORELLA AVE	91607	2	168B169   842	2355016058	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	ADDRESS	34.15487	-118.39016	INSTALLING PV1 SYSTEM ON THE ROOF. SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE IS 6.048 kW. USING A TOTAL OF 28 MODULES. MICRO-INVERTER STANDARD PLAN. [MICROINVERTER: ENPHASE M215.] [MODULE: SUNMODULE SW 240POLY]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59966	18041-20000-29790	20808 W SPRUCE CIR (#70)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.295	-118.58735	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59967	17041-10000-16773	2464 N FLETCHER DR	90039	13	150A209    54	5437033029	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.107	-118.25511	PC FOR POWER AND ENERGY.  addition OF TWO STORY (parking garage at 1st floor, storage area at 2nd floor) TO AN EXISTING BUILDING. SERVICE SIZE 1000AMP, 3 PHASE 4 WIRE, TOTAL AREA: 3588 SQ FT.B # 14014-20000-00750	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59968	18041-30000-32217	11280 W PEACH GROVE ST	91601	2	168B173   296	2353022008	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Apartment			08/23/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	01/27/2021 12:00:00 AM	ADDRESS	34.15901	-118.37715	PC FOR NEW THREE STORY 21 APARTMENTS BUILDING TYPE V-A OVER ONE LEVEL OF AT GRADE TYPE I-A GARGE.SCOPE INCLUDES NEW SERVICE RATED AT 1200A 120/240 3PH SERVICE. 7 TYPICAL UNITS  WITH TOTAL AFFECTED AREA 8500 SQ.FT. B# 18010-30000-03511	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59969	13041-10000-34478	23938 W OXNARD ST	91367	3	177B089   619	2045017023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	07/12/2014 12:00:00 AM	ADDRESS	34.1796	-118.64856	PV1, Install a 10.5 kw DC roof-mounted solar array system interconnect with main service panel with (2) transformerless inverter(s)[SOLAREDGE # SE3800A-US and SOLAREDGE # SE6000A-US] and (42) modules[AU OPtronics # PM245P01_250W] for 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59970	18041-20000-35906	3222 N BENDA PL	90068	4	157-5A183  17	5579037004	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.12801	-118.34426	Plan check for a PV1 roof-mounted PV system. System size is 15.48 kWdc/14.08 kWac-CEC and consists of (43) micro-inverters, (43) panels, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59971	19041-10000-16187	963 E 4TH ST 2nd Floor	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.04337	-118.23442	Change of use from retail to office on the 2nd floor. Installing new LED lights, receptacles and 2 225A panel. Total area 27109 SF.Building Permit:: 19016-40000-11061Contractor to verify connected load and #of new circuits.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59972	13041-10000-09803	1705 N SILVERWOOD TER	90026	13	144A207   144	5423020016	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.08896	-118.26707	PV1 ONE STORY SINGLE FAMILY DWELLING. MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 4.1KW. 19 MODULES. [MICROINVERTER: ENPHASE 215] [SOLAR MODULE: LG 260SIC-G3]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59973	12041-10000-25680	453 S SPRING ST	90013	14	129A211    87	5149024001	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/26/2012 12:00:00 AM			Reviewed by Supervisor	11/16/2012 12:00:00 AM	ADDRESS	34.04778	-118.24948	PV2 SOLAR INSTALLATION WITH 297 MODULES IN 27 STRINGS AND (1) 68.31KW INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59974	15041-10000-36111	4420 N ROCHELLE PL	91316	5	165B133    86	2292017029	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM			Reviewed by Supervisor	11/03/2015 12:00:00 AM	ADDRESS	34.15144	-118.50849	PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE: 12 KW-AC. (54) MODULES AND (2) INVERTERS. (2) SOLAREDGE TECHNILOGIES:SE6000(240V)(54)REC SOLAR: REC275TP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59975	19041-10000-42287	633 W 5TH ST	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	06/04/2020 12:00:00 AM		Permit Finaled	09/23/2020 12:00:00 AM	ADDRESS	34.05099	-118.25468	Power plan check for a commercial building TI. Scope inlcudes a medium voltage transformer supplying a 1200-amp board along with (5) panels and other associated load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59976	10041-10000-18028	10717 S CENTRAL AVE	90002	15	090B209  1510	6051014002	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Finaled	08/31/2011 12:00:00 AM	PIN	33.93863862	-118.25452766	NEW ONE STORY COMMERCIAL SUBDIVIDED INTO 3 EA TENANT SPACESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59977	16041-20001-18102	1201 W 5TH ST 1st Floor	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.05429	-118.25967	11.18.2016 - Plan check for modifications to approved set. Change plug lights to hardwired, remove UPS room, and remove panel 1PE3.======TI to (E) commercial production studio and associated spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59978	13041-20001-25178	15040 W BASSETT ST	91405	6	183B145   562	2220016016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.19608	-118.4612	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELING. TOTAL SYSTEM SIZE 4.7 KW AC USING 22 MODULES. USING ENPHASE MICROINVERTER M215. NONSTANDARD PLAN. 2 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59979	14041-20000-17395	6053 W CENTURY BLVD 7TH FLOOR	90045	11	093B169   305	4124030902	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	33.94648	-118.38998	PLAN CHECK FOR TITLE 24 ENERGY ONLY.  EXISTING HIGH RISE BUILDING NEW LIGHTING FIXTURES.  ALL CIRCUITS ARE EXISTING NO NEW LOADS.  WORK TO BE DONE IN THE 7TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59980	18041-10000-25998	502 S HARVARD BLVD	90020	10	135B193   661	5503023009	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			07/26/2018 12:00:00 AM	05/15/2020 12:00:00 AM		Permit Finaled	12/07/2023 12:00:00 AM	ADDRESS	34.06515	-118.30392	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES A NEW SERVICE RATED AT 1600A 120/208V 3PH. TOTAL AFFECTED AREA 61684 SQ.FT ( INDOOR + OUTDOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59981	17041-10000-24949	5500 N KLUMP AVE #1-#84	91601	2	174B173  1273	2350005016	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			07/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.17012	-118.37509	PC FOR FA  FOR A 5 story 84 unit apartment with garage.TOTAL OF 208 DEVICES WITH 6 PANELS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
59982	19041-10000-34644	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.09783	-118.36466	PC for T24 only, scope of work is changing lights in wax rooms to LED. All controls and circuits are exisiting to remain. Total affected area is 480 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59983	19041-20000-27377	22713 W SYLVAN ST	91367	3	177B097    19	2039020016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.18476	-118.62161	Plan check for a PV1 roof-mounted PV system. System size is 14.175 kWdc/12.973 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (45) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59984	17041-20000-22684	10810 N SWINTON AVE	91344	12	207B137   211	2680006012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.26661	-118.48575	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
59985	16041-10000-45643	5124 W ADAMS BLVD	90016	10	123B177   999	5049014009	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			Reviewed by Supervisor	02/13/2017 12:00:00 AM	ADDRESS	34.03228	-118.35322	Full plan check to a 3 story, 6 unit apratment/mixed use building (retail and parking and first level). New service rated at 800 amps 240/120V 3ph 4w. Total area: 3478.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59986	19041-10000-53212	16325 W VENTURA BLVD	91436	5	168B137   354	2260009045	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	07/08/2020 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.15731	-118.48907	FULL PC FOR POWER AND LIGHTHING. 2 SERVICES AT 800A AT 277/480V. SCOPE OF WORK INCLUDES PANELBOARDS, MOTORS AND BRANCH CIRCUITS. TOTAL AFFECTED AREA IS 37,217 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59987	17041-10002-17275	1156 S VICTORIA AVE	90019	10	129B189   419	5082025021	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.05137	-118.32603	Supplemental to changes to approved set of plans - changes include increasing the of main breaker from 150A to 200A - sum of all branch breakers <200A for 200A main panelInstallation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  1 new Tesla AC Powerwall 5.8 kVA 13.0 kWH battery and 1 new Solicia 7.6 kWac TL inverter (32 modules).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59988	17041-20000-08157	4001 N EVADALE DR	90031	1	145-5A227  75	5303010013	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco, Historic Highland Park	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.09421	-118.19841	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.2 KW AC MODULE SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59989	17041-10002-37289	8619 S HAAS AVE	90047	8	097-5A191 317	6036001044	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Issued	11/13/2017 12:00:00 AM	ADDRESS	33.95936	-118.31736	SUPPLEMENTAL FOR POWER WALL 2 BATTERY INSTALLATION WITH THE PV SYSTEM ON MASTER PERMIT. SCOPE INCLUDES ONE POWERWALL AND TWO SUBPANELS. PC FOR ROOFMOUNTED PV ON SFD. SYSTEM SIZE 3.0KWAC/3.0KWDCSCOPE INCLUDES SINGLE INVERTER WITH 10 MODULESPOWERWALL 2 BATTERY INCLUDED WITH  (UNDER SUPP.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59990	16041-10000-07407	1151 W 58TH ST	90037	9	108B197  1326	5002017028	RD2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	33.98978	-118.29553	PV1, ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTERS. (20) MODULES AND (20) MICRO-INVERTERS. TOTAL SIZE IS 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59991	17041-10003-38466	10409 N CANBY AVE	91326	12	204B125    39	2731013015	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.2596	-118.53515	PC FOR REVISIONS TO APPROVED SET TO REFLECT SERVICE UPGRADE.  THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER ORIGINAL. install new Rooftop solar system on a SFD. system is 5KW ac (20 modules) (1 inverter)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59992	15041-10000-17001	595 E VENICE BLVD BLDG 2	90291	11	108B145  1466	4241037012	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	33.99003	-118.46131	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59993	13041-10000-07297	4820 N CARPENTER AVE	91607	2	168B169   371	2355018009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.15825	-118.39089	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.6KW. USING 44 MODULES. TRANSFORMERLESS INVERTER, NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
59994	17041-20000-41708	12358 W JEROME ST	91352	6	198B165   362	2629016012	RS-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.2355	-118.4024	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (16) micro-inverters, (16) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59995	16041-10000-39629	2803 S VINEYARD AVE	90016	10	123B181  1294	5057010013	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.03103	-118.34483	PV2 COMMERCIAL ROOFTOP. PC FO PV SYSTEM IS 3KW AC USING 8 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
59996	14041-20000-33375	2733 W SAN FERNANDO ROAD	90065	1	150B213   212	5457007011	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.11016	-118.24249	Change of use from machine shop to office building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59997	18041-10000-18359	810 E PICO BLVD #223	90021	14	123A211   488	5132019048	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.03119	-118.25079	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 4380 SQ. FT. B#18016-10000-13683	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59998	17041-10000-19853	801 S GRAND AVE SUITE 375	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.04581	-118.25842	Title 24 plan check.  T.I. to existing office space.  Subpanels to remain existing with new lighting and receptacles.  Total area = 4,790 sq. ft.       Building permit #17016-10000-11662	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
59999	15041-10000-34756	740 S RIDGELEY DR	90036	4	132B181   133	5089005011	[Q]R4-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			10/19/2015 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.06127	-118.35077	PC FOR POWER AND ENERGY. 5-STORY 25-UNIT APARTMENT BUILDING WITH 2 LEVEL GARAGE .6 TYPES APRTMENT. TOTAL AREA 22,000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60000	12041-10000-30761	196 E JEFFERSON BLVD	90011	9	118-5A205 315	5120007006	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM			PC Approved	12/21/2012 12:00:00 AM	ADDRESS	34.01717	-118.26972	PLAN CHECK FOR TITLE 24. T.I. INSTALLATION OF NEW LIGHTS FOR OFFICE AREA. SINGLE STORY MANUFACTURING. NO EMERGENCY LIGHTS, PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60001	17041-20000-04946	304 S BROADWAY	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.05076	-118.248	Facade lighting for commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60002	19041-10000-38608	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 167	5544025035	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.10155	-118.31097	"REMOVE HID FIXUTRES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY ""FITNESS CENTER""  INDOOR"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60003	10041-10000-05875	2206 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.03796	-118.44083	T.I. for an existing building (Tutti Fruitti).  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60004	17041-10000-11407	1261 S STONER AVE 1-6	90025	11	129B145   887	4263008009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Apartment			04/07/2017 12:00:00 AM			PC Approved	08/07/2017 12:00:00 AM	ADDRESS	34.04711	-118.46065	Full PC for power and energy for a new 4 story 8 unit apartment, 4 story building with garage. Scope includes a new 800A 120/240 3 phase 4 wire service/distribution board, new panels, and new circuits. There are three typical panels for all 8 units. Total affected area is 16048 Sq. ft. B#16010-30000-01721	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60005	14041-10000-10041	1511-1517 N WILCOX AVE	90028	13	147A187   604	5547017036	C4-2D, C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.09839	-118.33114	Change of use to office space from retail, new ADA compliant restrooms.Plan chk  is for title24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60006	10041-20001-02316	1151 N HIGHLAND AVE	90038	4	144B185   524	5532019002	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM			PC Approved	04/13/2010 12:00:00 AM	ADDRESS	34.09213	-118.3388	Revision to Lighting changes to 10041-20000-02316 Tenant improvement - remodel of (E) office building. Title 24 only. Emergency lighting is existing-to-remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60007	12041-10001-26070	5826 W OLYMPIC BLVD	90019	4	132B177   757	5085003031	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			01/21/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.05724	-118.35691	Changes made to previously approved set ((((   service up grade , elevator feeder  up grade   .  M.Z.  1-21-16))))))))                       Full plan check for new apartment building, four story, 12 unit. Project is located in Methane Zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60008	11041-10000-16025	4034 W EDENHURST AVE	90039	13	157-5A205 140	5594029012	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	08/22/2011 12:00:00 AM	ADDRESS	34.12537	-118.26745	Installation of Enphase Inverters on the roof of a single family dwelling.  Modification for use of Enphase M215 inverters was submitted on August 1, 2011.  Fire Department approval was on plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60009	19041-10000-25236	20211 W RUNNYMEDE ST	91306	3	186B113   397	2114006010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.20602	-118.57355	0$ final fees per AB1414PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 47 MODULES (Q-CELL 285) AND 47 MICROINVERTERS ENPHASE IQ7.  SYSTEM SIZE IS 13.395KWdc and 11.385KWacMAIN BREAKER DERATE TO 175A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60010	17041-20000-43983	8833 N MCLENNAN AVE	91343	12	195B133   271	2688028028	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.23118	-118.50102	Install 13.5 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60011	14041-10000-24735	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	New one story commercial building. New 2000 Amp Service. Core & Shell Only.DUE TO BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60012	10041-20000-00456	6740 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			01/11/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Finaled	04/07/2010 12:00:00 AM	ADDRESS	34.1185	-118.34057	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60013	16041-10000-33432	15231 W SUNSET BLVD	90272	11	129B125   621	4423016009	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	34.04675	-118.52481	T24 ONLY. CHANGE OF USE FROM RETAIL TO BANK: TOTAL AREA 2387 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60014	16041-20000-40822	988 N HILL ST	90012	1	136-5A215 187	5414007***	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.0667	-118.23737	remove existing hid fixtures and replace with led.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60015	10041-20000-14182	8221 W MARMONT LANE	90069	4	147B173   195	5555030010	R4-1D	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM			PC Approved	07/22/2010 12:00:00 AM	ADDRESS	34.0981	-118.36829	replacing lighting fixtures in kitchen area in restaurant. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60016	16041-20000-18695	4304 N LACLEDE AVE	90039	13	159B205   452	5594004012	RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.13148	-118.26672	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60017	15041-10000-24430	16027 W VENTURA BLVD STE 500	91436	5	168B141   538	2261022106	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.15641	-118.48225	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO A NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK IN SUITE 500**REPLACEMENT APPICATION FOR 15041-10000-21187.*** PERMIT FEES PAID UNDER 15041-10000-21187.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60018	14041-10000-21899	888 W 6TH ST 1ST FL-MEZZANINE	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.05062	-118.25846	Plan check for power only. FEES ARE CALCULATED ON THIS APPLICATION.   Title 24 plan check on separate application # 14041-10000-21285.Interior renovation of part of an office building for a new tenant.  The existing panelboards will be replaced (total connected load = 550 A).  New panelboards, conduit, wiring, recepticles, emergency lighting and equipment.30 day demand variance filed on 10/10/2014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60019	17041-10000-19451	1423 E 18TH ST	90021	14	120A213   140	5129008034	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.02348	-118.24663	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60020	18041-10000-01783	2430 E 11TH ST	90021	14	120A217    70	5168003008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM			Reviewed by Supervisor	02/07/2018 12:00:00 AM	ADDRESS	34.02355	-118.22911	CHANGE OF USE: EXISTING WAREHOUSE/OFFICE TO WAREHOUSE/OFFICE/COMMISSARY, INT T.I. OF EXISTING OFFICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60021	17041-20000-13949	17029 W INDEX ST	91344	12	210B133    65	2697020017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.27583	-118.50329	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.9 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60022	09041-10001-14057	350 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM			PC Approved	03/15/2010 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check only. Plan check for Delta 2 revision to approved plans. Remove sheet E24CE5, E34CE5,  and changes sheet E33CE9, E5010, and T-24 calculation (additional fixtures added to ramp area).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60023	11041-10000-11925	304 S BROADWAY basement	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	06/29/2011 12:00:00 AM		Permit Finaled	10/12/2011 12:00:00 AM	ADDRESS	34.05076	-118.248	Replace an existing fused 600 ampere and 800 ampere distribution equipment with new 600 ampere and 800 ampere distribution equipment of  the same rating but with circuit breakers, and reconnect existing feeders.  The equipment is located in the basement of the Bradbury Building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60024	13041-10003-26542	8055 W 3RD ST	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	34.07218	-118.36515	((10/7/2014 - Changes to approved set.  Change in lighting fixtures (indoor and outdoor) and changes to series rated breakers in panels and switchgear at request of inspector))(applicant brought in revised sheets 10/16/2013 - fees to be added for new changes.)PC FOR POWER ONLY. (E) BLDG CHANGE 1P3W TO NEW 3P4W SERVICE + house panel (200A) and 5 tenant panels (1x 400A and 4x 200A).  No current tenants - modification of a currently shell building for future TI. METHANE ZONE.SUBDIVIDE EXISTING BUILDING FROM THREE TENANT SPACES INTO 5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60025	12041-20000-17686	21250 W CALIFA ST 105	91367	3	174B105    16	2149002018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM			PC Approved	07/30/2012 12:00:00 AM	ADDRESS	34.1769	-118.59414	T-24 plan check only for suite 105 remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60026	19041-10000-13197	20000 S VERMONT AVE	90502	15	057B197   153	7351033061	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM			Verifications in Progress	05/30/2019 12:00:00 AM	ADDRESS	33.84914	-118.29027	PC for Power(no lightings), for EV assembly.change of use from a warehouse.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60027	13041-20000-08150	9442 N HAYVENHURST AVE PV-1	91343	12	198B137   124	2676001013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2013 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.24225	-118.49356	PV-1. Plan check for microinverters. 6.45kW AC total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60028	19041-20001-04712	9007 N WOODMAN AVE Unit A	91331	6	195B153   291	2639033006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.23306	-118.43913	Plan check for power first time tenant. Energy plan check issued under master. Plan check only, permit covered under master application 19041-20000-04712	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60029	19041-10000-25643	4575 W SANTA MONICA BLVD	90029	13	144B197   669	5542027031	C2-1D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Apartment			07/12/2019 12:00:00 AM	11/16/2021 12:00:00 AM		Permit Finaled	12/11/2023 12:00:00 AM	ADDRESS	34.09107	-118.2885	FULL PLAN CHECK FOR A  NEW (16) UNIT 5 STORY APARTMENT BUILDING WITH (2) EXTREMELY LOW INCOME UNITS AFFORDABLE HOUSING PER DIR-2018-247-SPP-TOC-SPPA. SCOPE INCLUDES NEW 800A 120/240 3� 4W SERVICE. TOTAL AFFECTED AREA IS 20,325 SQ.FTFA VARIENCE HAVE NOT BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60030	16041-20000-45297	14349 W VICTORY BLVD	91401	6	180B149   830	2237022022	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	02/10/2017 12:00:00 AM		Issued	02/10/2017 12:00:00 AM	ADDRESS	34.18685	-118.44607	Plan check for installation of solar pv system, roof-mounted on commercial building. Interconnect with a 400A MSP. 10kW grounded system. (34) 285W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60031	19041-10000-30869	201 W SOTELLO ST	90012	1	136-5A217 146	5409003029	UV(CA)	Central	Central City North	Historic Cultural North		2060.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.06692	-118.23009	REPLACE INDOOR AND OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60032	15041-10001-17470	6007 S ST ANDREWS PL	90047	8	105B193   569	6001018009	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	33.98484	-118.3116	Change to an approved set by clarify the existing equipment and properly sizing the MSA board and the size of service. Note. all changes are under delta-1 only.ADDING NEW FEEDERS TO FUTURE TENENT UNIT 1.  EXISTING SERVICE/SWITCHGEAR.  LOADS TO BE ON SEPARATE PERMIT.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60033	18041-20000-22619	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.1937	-118.49152	Plan check for PV roof mounted on commercial building, system size; 75kW with 265 modules and 3 inverters(30kW) connected to  800A  Service.Fee $ 0.00 due to California Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60034	13041-20000-18245	12317 W NAVY ST	90066	11	117B153   598	4248005019	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.01711	-118.44327	pv1 single family dwelling. total system size 4.2 kw using total of 17 modules. using transformerless inverter nonstandard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60035	18041-20000-33406	20706 W BEECH CIR #292	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.29254	-118.58451	Plan check for PV roof mounted system size: 3.02kW with 9 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60036	18041-10000-13037	915 W WILSHIRE BLVD STE 1000	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.05069	-118.2599	INTERIOR TENANT IMPROVEMENT  IN OFFICES ON THE 10TH FLOORPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60037	19041-10000-21269	7929 W MELROSE AVE	90046	5	141B177   525	5527012901	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM			PC Info Complete	06/05/2019 12:00:00 AM	ADDRESS	34.08394	-118.36246	PC (energy only) for senior center. area of scope 9,555SF.Plan Check Only. Permit Number: 19041-10000-05026	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60038	18041-10000-09550	3800 S VERMONT AVE	90037	9	117B197   615	5037028912	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Closed	11/07/2023 12:00:00 AM	ADDRESS	34.01684	-118.29134	TEMPORARY CONSTRUCTION POWER FOR THE LUCAS MUSEUM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60039	13041-20000-31812	513 W AVENUE 37	90065	1	145-5A221 195	5451023006	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Expired	12/10/2015 12:00:00 AM	ADDRESS	34.09328	-118.21528	PV1 TRANSFORMERLESS SYSTEM. 10 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 3KWAC. MAXIMUM HIEGHT FROM ROOF TO TOP OF THE MODULE DOES NOT EXCEED 18 INCHES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60040	19041-20000-09015	9350 N ETON AVE	91311	12	198B105    64	2746010016	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.24087	-118.59542	T24 PLAN CHECK FOR EXISTING COMMERCIAL LOW RISE. INSTALLING LIGHTS, CONTROLS, RECEPTACLES, AND 4 AC UNITS. TOTAL SQUARE FOOTAGE = 2123 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60041	13041-10000-30697	7475 N FALLBROOK AVE C;  HALL-SERVICE	91307	12	186B097   417	2021015014	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			11/04/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.2064	-118.62364	"POWER PLAN CHECK FOR EXISTING CHURCH HALL BUILDING. REPLACING EXISTING 200A SERVICE WITH NEW 600A OVERHEAD 120/240V , 1-PHASE, 3W. (2) NEW FEEDERS ADDED TO EXISTING PANELS ""A"" AND PANEL ""CR"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60042	15041-10000-08921	5300 S VERMONT AVE	90037	9	108B197   418	5001005030	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			PC Info Complete	08/13/2015 12:00:00 AM	ADDRESS	33.99389	-118.29133	Energy (in/outdoor) plan check for a commercial building. Total area is 9150-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60043	17041-20000-15718	5807 N LAUREL CANYON BLVD	91607	2	174B165   210	2340012024	R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			05/11/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.17595	-118.39684	Energy plan check for an apartment.  Replacement to existing lighting corridor lighting.  plan check for energy only.thi is plan check only.  fees paid under application number 17041-20000-01739	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60044	16041-20001-10764	822 N SARBONNE ROAD	90077	5	141B149    78	4370002026	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM			PC Approved	05/19/2016 12:00:00 AM	ADDRESS	34.08479	-118.44904	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.84 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60045	17041-10000-44422	5027 N MONTEZUMA ST	90042	1	151-5A225  52	5469009037	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.11101	-118.20559	NEW ROOFTOP SOLAR SYSTEM WHICH CONSIST OF 14 MODULES(Q.PEAK-G4.1 295),OPTIMIZERS (SOLAREDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE3800H-USRGM)SYSTEM SIZE IS 3.8KWac AND 4.48KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60046	11041-10000-08859	9725 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			Not Ready to Issue	01/31/2012 12:00:00 AM	ADDRESS	34.24604	-118.41908	EXISTING TARGET.  MODIFICATIONS TO EXISTING PLANS UNDER PERMIT # 10041-20000-25749.   CONTRACTOR TO DROP OFF SET OF APPROVED PLANS.   MODIFICATIONS ARE TO REPLACE EXISTING SWITCHBOARD AND EXISTING TRANSFORMER.  FULL PLAN CHECK.see 12041-20000-02289 for Electrical permit/ Service only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60047	17041-10000-31307	8440 N BALBOA BLVD #101	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	FIRST TENANT -PIZZAPRESS- IN NEW COMMERCIAL BUILDINGFULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60048	17041-10001-10065	12035 W WILSHIRE BLVD	90025	11	126B145    25	4265016043	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	34.04541	-118.46622	11/14/18 MAJOR CHANGES TO APPROVED SET. PLANCHECK ONLY. ALL CHANGES ARE SHOWN BOLD . CHANGES TO COMMON AREAS ( ALL ELEV LOBBY, CORRIDORS (3 LEVELS: P1 TO 2ND FL), PH UNITS AND OFFICES)NOTE: PERMIT IS PAID UNDER PCIS#17041-20000-10065	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60049	16041-20000-07024	3476 E WHITTIER BLVD #108	90023	14	121-5A227 196	5188017001	C1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.0265	-118.19877	Plan check for energy only. CHANGE OF USE FROM (E) RETAIL TO (N) RESTAURANT (Yogurtland). New lighting (incl. emergency). 1,208sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60050	13041-20001-30013	3600 N MOUND VIEW AVE	91604	2	159B165    31	2376018017	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.13583	-118.39339	((CHANGES MADE TO APPROVED SET OF PLANS. CHANGED DC SIDE GND TO #10))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. 18 MODULES AND 1 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60051	18041-10000-44466	7635 N BURNET AVE	91405	6	186B145    72	2209034032	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.20956	-118.46305	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60052	17041-10000-05970	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.03145	-118.41085	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 200650 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60053	11041-10000-25250	4700 N LOUISE AVE	91316	5	168B133   426	2289009015	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.15474	-118.50947	New 8.4 KW roof mounted photovoltaic system for a single family dwelling with seperate pool house.  Modules on main house and pool house. Two inverters located in garage of main house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60054	17041-10000-12352	3604 N GLENRIDGE DR	91423	4	159B157    63	2272029023	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.13565	-118.4321	PC for new rooftop solar PV. Total system size is 13.9KW and includes 41 SPR-X21-345-C-AC AC modules. one 125A load center .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60055	14041-10000-13529	1548 N MERCURY DR	90042	14	159A229   598		R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.12791	-118.18924	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 2.59KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60056	15041-20001-17492	232 S CATALINA ST	90004	13	135B197    86	5518022007	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Apartment			02/10/2016 12:00:00 AM			PC Info Complete	03/30/2016 12:00:00 AM	ADDRESS	34.0698	-118.29525	(N) 600A service equipment, feeders, unit panels, and new circuits in (E) 3-story 12-unit apartment building.  Plan check per inspector request.  Original permit only covers the new branch circuits.  (((RE-WIRE)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60057	18041-10000-07471	1030 N SWARTHMORE AVE 2-107	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR POWER AND ENERGY FOR INITIAL TENANT IMPROVEMENT TO EXISTING CORE & SHELL RETAIL SPACE WITHIN PALISADES VILLAGE. SCOPE INCLUDES NEW PANEL, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 1225 SQ.FT. B#18016-10000-06123	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60058	16041-10000-11424	12380 N LONGACRE AVE	91344	12	219B125   129	2601075065	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.29477	-118.53441	PV1 roof mounted solar system installation to a single family home using microinverters with a main derate and a PV monitoring device. Derate is for pv-feedback only. (47) Modules and (47) Micro inverters, Total system rated at 11.75 kw.fees are $0 due to senate bill 12222	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60059	16041-20000-41472	1447 N MARTEL AVE SLS#3	90046		147B181  1153	5550021013							Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Plans on Hold	12/02/2016 12:00:00 AM	ADDRESS	34.09728	-118.35102	New 4-story single family dwelling with subterranean attached garage.  Small lot subdivision.  Collective service for (6) new SFDs on same lot.  Plan check for power and energy.  Service equipment, house panel, and energy fees charged on unit #1.  Building permit filed under 16010-10000-02540 et al	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60060	16041-10002-05065	2633 E CESAR E CHAVEZ AVE	90033	14	127-5A225  16	5177033029	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Issued	05/19/2017 12:00:00 AM	ADDRESS	34.0454	-118.20418	PC FOR POWER. REVISION TO APPROVED SET OF PLAN. CHANGES IS UNDER DELTA 12, INCLUDING ADDITION OF ONE 800A DISTRIBUTION BOARD AS MAIN PANEL  INSTEAD OF SUPPLYING OF THE PANELS INDIVDUALLY. EXISTING SERVICE 600A.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60061	09041-10002-21578	612 S LORENA ST	90023	14	123A227   297	5186014028	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM			PC Approved	01/21/2010 12:00:00 AM	ADDRESS	34.0306	-118.19896	Change to approved plans, change from Siemens to Square D series rated breakers in plan notes, and provide new subpanel to supply previously approved  AC-1 and 30KVA transformer..  Permit issued on application 09041-10003-06290.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60062	16041-20002-00123	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	33.97615	-118.42138	[[[ 3/1/17 CHANGES TO APPROVED SET. DELTA 12 CHANGES ONLY. CONDUIT AND METHANE SEALS AT SERVICE EQUIPMENT MOVED FROM TOP TO BOTTOM.  REMOVE CAMLOCK AND TRANSFER SWITCH]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60063	19041-20000-14911	12408 N JOLETTE AVE	91344	12	219B133   444	2608024013	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.29644	-118.50432	PLAN CEHCK FOR INSTALLATION OF A 13.5 KWH TESLA POWER WALL TO EXISTING SFD WITH EXISTING PV SYSTEM. ALSO INSTALLING A 200A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60064	14041-10000-06517	740 S BROADWAY	90014	14	127-5A209 107	5144015023	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.04414	-118.25412	Plan check for power and energy. A theater in a night club. Total Area 9448 sq ft.According to the applicant extention of work is not determined.They're submitting as new plan check. The only 2 basement panel are not included.>>Inspector: please note, according to plan only area A, B, C and D (bar area , restroom and entry) total square footage is less than 2000 sqft as part of this scope, emergency area in theater is existing, fire alarm is existing.  Servcie of 600 amp is existing to remain.>>> clearnce from CRA obtained	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60065	18041-10000-10559	513 E 7TH ST	90014	14	126A213    56	5148025024	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	09/08/2021 12:00:00 AM	ADDRESS	34.04099	-118.24687	***** SEE APPLICATION COMMENTS******PC FOR A NEW 7 STORY HIGH RISE RESIDENTIAL APPARTMENT BUILDING OVER ONEOR TWO  LEVELS OF PARKING. SERVICE RATED AT2000A 120/208V SCOPE INCLUDES 81 UNITS. TOTAL AFFECTED AREA IS 20680 SQ.FT.FA MODIFICATION HAS BEEN SUBMITTED WITH THE DEPARTMENT. 03/22/201817010-10001-03238	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60066	15041-20000-09941	10821 S COMPTON AVE	90059	15	088-5A213 173	6070003029	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	33.93717	-118.2464	Installation of new roof mounted solar PV array.  Total system size = 4.3 kWac.  Microinverter system with 20 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60067	13041-10000-27139	20314 W VIA MANTUA	91326	12	219B113   238	2701059030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	34.29836	-118.57602	PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 6.25 kW. TRANSFORMERLESS INVERTER. 2 STORY.(25) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-5000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60068	18041-10000-15905	1601 E 103RD ST 7-B	90002	15	091-5A213 177	6048013927		South Los Angeles				2423.00	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	33.94385	-118.24586	PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT. TOTAL AFFECTED AREA IS 1633 SQFT.BUILDING PERMIT : 18016-10000-13414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60069	10041-10000-08057	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM	04/30/2010 12:00:00 AM		Permit Finaled	09/01/2010 12:00:00 AM	ADDRESS	34.04107	-118.25479	T-24 plan check for remodeled portions of an existing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60070	15041-20000-06840	8510 N CAPISTRANO AVE	91304	12	192B101   196	2004017026	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.22478	-118.6163	PV1. Standard plan. Install roof mounted PV system on SFD.System size 10 kW.Grounded system.Interconnected with 225A main service panel. (28) 327W Modules(1) 10001 T Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60071	17041-10000-16895	4680 N EAGLE ROCK BLVD	90041	14	159A221   231	5685026010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			PC Info Complete	05/19/2017 12:00:00 AM	ADDRESS	34.12969	-118.21667	PC for title 24 for  CHANGE OF USE FROM RETAIL TO RESTAURANT . Energy only for new lights and receptacle with new kitchen equipment. total affected area 1210sq.ft. BL# 17016-10000-07347	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60072	14041-10000-31774	2748 W 8TH ST #201	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.05747	-118.28552	TI to (E) commercial retail space.  Plan check for energy.  Existing permit under 14041-10000-31392	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60073	11041-20000-13182	12046 W VENTURA BLVD	91604	2	162B169   192	2369015016	C2-1VL, Q, P-1VL, Q	South Valley	Sherman Oaks - Studio City - Toluca Lake		YES	1438.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.14351	-118.39404	PLAN CHECK T24 GENERAL/EMERGENCY LIGHTING FOR INTERIOR TI FOR EXISTING BAGEL STORE. PERMIT FOR NEW CKTS AND WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60074	12041-10000-06126	1219 N WESTMORELAND AVE	90029	13	144B197   181	5542020021	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.00	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2012 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.09401	-118.28793	New 6.845KW roof mounted photovoltaic system for an existing single family dwelling.  Modules located on house and garage roof. Additional permit for 225A service panel upgrade and branch circuit for PV data acq. system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60075	18041-10001-22539	2626 S 7TH AVE	90018	10	123B189   770	5051001012	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Apartment			06/18/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.03173	-118.32378	EXPEDITE PER APPLICANT REQUEST. ((((PV2. NEW SOLAR SYSTEM FOR AN EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE IS 4.575KWdc / 3.30KWac.(15)MODULES-HANWHA Q-CELLS# Q.PEAK-G4.1/SC305(1)INVERTER-ABB# UNO-DM-3.3-TL-PLUS-US-SZ-RA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60076	10041-20000-05247	12744 N SAN FERNANDO ROAD BLDG 3	91342	7	222B145   396	2506003010	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/23/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	07/14/2010 12:00:00 AM	ADDRESS	34.30155	-118.46112	MULTIPLE REVISIONS TO PCIS# 09041-20000-03797 (new industrial bldg).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60077	14041-10001-27478	1122 W 20TH ST	90731	15	012B193  1023	7460027022	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2972.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/27/2014 12:00:00 AM	ADDRESS	33.72622	-118.30182	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60078	19041-10000-07849	19750 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.85128	-118.29031	Removal of existing FAP and replace with new FAP. Installation of new (82) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60079	19041-10000-11579	4607 W SATURN ST	90019	10	126B185   375	5071020019	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.04334	-118.33871	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SOLAR EDGE SE3800H-US) WITH 16 MODULES USING P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60080	19041-10000-12111	330 S HOPE ST 2ND FLOOR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/28/2020 12:00:00 AM	ADDRESS	34.05319	-118.25252	Full plan check for FIRST TIME TENANT ON THE 2ND FLOOR. Scope includes new lighting and equipment with a total area of  12,671 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60081	10041-20000-16650	601 S FIGUEROA ST 37th Floor	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check T-24 energy general/emergency lighting on 37th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60082	12041-10000-18703	3041 W 7TH ST	90005	10	132B197   169	5077011018	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/09/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.05992	-118.29006	Install new addressable fire alarm system in an existing mixed use, commercial/college.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60083	15041-20000-20377	13724 SHERMAN WAY	91405	2	183B157   987	2216027023	(Q)C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	PIN	34.20070651	-118.43211614	Plan check Title 24 only for existing restaurant T.I. Total indoor lighting area: 2,260 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60084	15041-10000-07967	10431 W SANTA MONICA BLVD	90024	5	132B157   661	4327006008	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	PIN	34.05716086	-118.42526721	Energy plan check for a change of use from retail store to a bank; total area is 7336-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60085	13041-10000-00244	8125 N CORBIN AVE	91306	3	189B117   120	2106014003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.21751	-118.56245	PV1 - 1 STORY HOUSE 28 SOLAR MODULES [MODULES: LG ELECTRONICS {LG250S1C-G2}] [INVERTER: POWER-ONE-PV1-6000-OUTD-US 240V]UPGRADED MAIN SERVICE PANEL 200A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60086	10041-10000-08642	3800 W WILSHIRE BLVD #207 E,F&J	90010	10	132B193  1202	5093005***	C2-2, R4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	04/06/2011 12:00:00 AM	ADDRESS	34.06139	-118.30931	CHANGE PORTION OF EXISTING 2ND FLOOR  FROM RETAIL TO MEDICAL OFFICE (M TO B OCCUPANCY); COMBINE 3 TENANT SPACES. TENANT IMPROVEMENT, (3500 SF);	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60087	15041-20000-30448	6316 N TOPANGA CANYON BLVD #K- 9040	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for 1st time tenant power and energy for Shoe Doctor Westfield Toanga Mall. Total area: 260 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60088	14041-10000-25476	380 W WORLD WAY 3RD FL	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	COFFEE BEANS AND TEA  LEAF KIOSK AT TBIT  3RD FLFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60089	19041-20000-52899	4661 N VISTA DE ORO AVE	91364	3	168A111    79	2174015019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.15462	-118.58132	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 17.49 KW DC/11.4 KW AC. SCOPE OF WORK CONSISTS OF (53) WITH OPTIMIZERS AND A 11.4 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60090	15041-10000-39687	5011 S NORMANDIE AVE	90062	8	111B193  1129	5016031024	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	PIN	33.99786079	-118.30049597	PV1, ROOF MOUNTED SOLAR SYSTEM. 21 MODULES AND 1 INVERTER. TOTAL SIZE: 7KW-AC.(21) SUNPOWER SPR-327-NE-WHT-D(1) SMA AMERICA SB700TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60091	19041-20000-41734	2049 S CENTURY PARK EAST 16th floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	T.I. OF PUBLIC REST ROOM PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60092	17041-10000-15293	8565 W PICO BLVD	90035	5	132B173  1025	4332027032	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.05377	-118.37756	PC for energy only, Outdoor Title 24. Removing HID fixtures and replacing them with new LED fixtures. Total area: 15,800 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60093	13041-10001-35566	1937 N GRAMERCY PL	90068	4	150A193    72	5587019009	R1-1D-HPOZ	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.10641	-118.31271	Expedited RSES plan check per applicant request.{{PV1, Install 2.65 kW DC roof-mounted solar array for a 3 story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (10) modules: Suniva OPT265-60-4-1B0.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60094	18041-10000-00620	150 N ENTRADA DR	90402	11	120B129    82	4410007027	[Q]C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			Corrections Issued	01/05/2018 12:00:00 AM	ADDRESS	34.02846	-118.51759	PC FOR RESTROOM TI IN OFFICE SPACE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 413 SQ.FT. B# 17016-10000-37702	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60095	17041-10000-09306	4979 W WASHINGTON BLVD	90016	10	126B181   936	5067014014	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.04073	-118.34838	PC for energy only, outdoor Title-24. Removing HID fixtures and replacing them with new LED ones. Area: 5,375.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60096	10041-10000-05819	5443 W CARLTON WAY	90027	13	148-5A193 236	5544021028	[Q]R4-2	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			03/31/2010 12:00:00 AM	05/26/2010 12:00:00 AM		Permit Finaled	03/11/2011 12:00:00 AM	ADDRESS	34.10063	-118.30849	Plan check power for new solar photovoltaic system 31KW. Fire Dept. approval stamp on seperate reduced size plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60097	18041-10000-16184	15055 W LA MESA ST	91342	7	228B145   323	2502005007	R1-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.31999	-118.46058	PC OF ROOF MOUNTED PV ON SFD. TOTAL SYSTEM SIZE 3.99KW DC 3.36 KWACSCOPE INCLUDES 14 MODULES WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60098	14041-20000-30870	717 S MORENO AVE	90049	11	126B141   235	4264007051	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM			Corrections Issued	01/16/2015 12:00:00 AM	ADDRESS	34.04281	-118.48391	PV1 SFD. TOTAL SYSTEM SIZE 20KW AC USING 80 MODULES. USING MICROINVERTER ENPHASE M250. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60099	15041-20000-24362	15939 W BAHAMA ST	91343	12	195B141   203	2672014005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.23303	-118.47981	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60100	16041-10001-28989	2005 W PICO BLVD	90006	1	129A201   230	5136023031	(Q)CM-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.04702	-118.28177	Expedite per applicants request.(Plan check for commercial 80KW solar system with 289 PVmodules and 1 inverter. **ROOFTOP SOLAR SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60101	13041-10000-22419	342 N SAN FERNANDO ROAD	90031	1	139-5A219   6	5447009017	MR2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	ADDRESS	34.07793	-118.22327	Remodel of existing media center room for Goodwill office.  T24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60102	19041-10000-10668	7223 S MAIN ST	90003	9	102B201  1028	6031001036	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	06/07/2023 12:00:00 AM	ADDRESS	33.974	-118.27409	Remove HID fixtures and replace with new LED fixtures (Outdoor Only), - T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60103	18041-10000-31192	11484 W DELANO ST	91606	2	177B169   508	2335034009	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1241.05	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.18204	-118.38203	This is supplemental plan check and permit to existing PV permit # 18041-90000-23110, this plan is to reflect the field installation. Plan check is requested by the inspector.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60104	09041-10008-08059	6250 W HOLLYWOOD BLVD	90028		148-5A189 132	5546029917	C4-2D-SN		Hollywood	Central Hollywood			Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM			PC Approved	01/22/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	Plan check only.  Supplemental application to approved plans to show revision to lighting work.  Changes are clouded.  Ckt L10HLD-12 is now routed through a lighting relay.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60105	10041-20000-12104	3415 S SEPULVEDA BLVD 5, 6,  9-Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	07/29/2010 12:00:00 AM	ADDRESS	34.02055	-118.42347	"Plan check T-24 Energy (general/emergency) lighting for corridor 5th floor area and restroom floor 5, 6, 9. All ciruits are existing. ""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60106	12041-10000-09712	8221 W 3RD ST	90048	5	138B173   822	5511019038	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.07267	-118.36879	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR BEAUTY SALON.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60107	12041-20000-08333	9815 N WHEATLAND AVE	91040	7	201B177   200	2542018011	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2012 12:00:00 AM			Reviewed by Supervisor	04/17/2012 12:00:00 AM	ADDRESS	34.2479	-118.35762	pv system 7.5 kw single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60108	13041-20000-12594	22350 W GERMAIN ST #4	91311	12	207B101   161	2723011***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	06/05/2013 12:00:00 AM	ADDRESS	34.2624	-118.61442	ROOF MOUNTED SOLAR ELECTRIC SYSTEM  8.5KW pv2. TOWN HOME. PC FOR PV SYSTEM ONLY. NO PERMIT TO BE ISSUED FROM THIS APPLICATION. PC ONLY. PERMIT ALREADY ISSUED UNDER EXPRESS PERMIT # 13041-20000-10405	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60109	14041-20000-07094	6600 N TOPANGA CANYON BLVD SUITE 98D	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	T24 FOR EXISTING RETAIL STORE. SCOPE OF WORK IN SUITE 98D	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60110	15041-20000-31204	21440 W VILLENA AVE	91364	3	168B105   623	2171002022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.15611	-118.59793	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(23) Hanwha G3-270W Modules(1) Solar Edge SE6000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60111	19041-20000-06382	9645 N ORION AVE	91343	7	201B145   496	2656013017	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	03/20/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.24611	-118.47198	PV1.  Install 11.10 kW roof mounted grid tied PV system with 9.8 kWh energy storage system.  (37) modules with 7.6 and 3 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60112	12041-10000-00264	14350 W VICTORY BLVD	91401	6	180B149   923	2240012027	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	05/21/2012 12:00:00 AM	ADDRESS	34.18643	-118.44602	NEW 7-11 STORE. PLAN CHECK FOR POWER AND T-24 ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60113	18041-30000-22848	2818 S LA CIENEGA AVE 2nd & 3rd-floor	90034	10	123B173   926	5065003037	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.03228	-118.37838	Plan check for T24 only, TI on (E) 2nd and 3rd floor office. Total area for both floor: 6,250 sq.ft.(B# 18016-30000-17955)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60114	15041-10000-06974	15401 W SUNSET BLVD	90272	11	129B125   477	4422022005	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM			PC Approved	04/07/2015 12:00:00 AM	ADDRESS	34.04822	-118.52719	Completed demolation of an existing building and rebuild a whole new convenient store (C-store)  at an exsiting gas station.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60115	13041-10000-23219	500 S GRAND AVE	90013	14	130-5A211 157	5149030001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM			Verifications in Progress	09/03/2013 12:00:00 AM	PIN	34.04986225	-118.25376975	PLAN CHECK FOR EMERGENCY LIGHTING AND TITLE 24 PART 6 ENERGY (CONTROLS) FOR THE 21ST FLOOR OF A HIGH RISE. SCOPE OF WORK IS LESS THAN 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60116	18041-10000-17987	318 S LINCOLN BLVD	90291	11	111B145   642	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Info Complete	05/15/2018 12:00:00 AM	ADDRESS	34.00111	-118.46697	TI IN AN EXISTING OFFICE BUILDING ON THE 2ND FLOOR IN SUITE# 200, 202 & 204.EMERGENCY LIGHTS EXISING TO REMAIN. SUBJECT TO FIELD INSPECTION.ALL PANELS AND CIRCUITS EXISTING TO REMAIN.PLAN CHECK FOR T-24 ENERGY ONLY.Permit was issued under 17041-10000-25538	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60117	14041-20000-06516	8412 W 3RD ST	90048	5	138B173   819	5511032044	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.07293	-118.37369	ENEGY PLAN CHECK BERRY  PIZZA PLACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60118	17041-20001-42117	7242 N VALJEAN AVE	91406	6	186B137   367	2205027029	MR1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM			PC Approved	01/05/2018 12:00:00 AM	ADDRESS	34.2024	-118.48575	Expedited plan check fee. PV2.  Install 52.36 kW DC roof mounted grid tied PV system.  (154) modules with (1) 24kW and (1) 30kW string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60119	14041-20002-29412	16260 W VENTURA BLVD Suite 800	91436	5	168B137   426	2284003033	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Approved	05/20/2015 12:00:00 AM	ADDRESS	34.15673	-118.48763	Plan check for changes to an approved set of plans. Changes include the change of fuse type and the AIC rating of (2) ATSs.*****Previous Work Description*****Supplemental express permit for change of address.Plan check for power and energy. TI to existing outpatient health care facility.  Install new generator and new 225A distribution equipment (new panels, transformers, etc.). New lighting system. Rewiring some existing circuits. 4,180sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60120	18041-10000-07016	1245 S HOLMBY AVE	90024	5	135B157   316	4326005021	R1-1	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.06498	-118.42913	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.20KWdc / 5.52KWac. (24)MODULES-SILFABSLA-M 300 300W(24)MICROINVERTER-ENPHASE IQ6-60	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60121	11041-20000-08566	4935 S MCCONNELL AVE	90066	11	105B157   583	4221031002	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM			PC Approved	04/28/2011 12:00:00 AM	ADDRESS	33.98281	-118.42353	energy plan check permit existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60122	18041-20000-35104	12217 W WILSHIRE BLVD	90025	11	126B145   243	4264026005	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM			PC Info Complete	09/13/2018 12:00:00 AM	ADDRESS	34.04331	-118.46874	Plan check for Title 24 Energy only in existing restaurant T.I. Total area: 2,911 sq ftB#18016-20000-08824	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60123	14041-20000-03546	3512 W GARDEN AVE	90039	13	154-5A207 347	5437007006	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.11682	-118.26057	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60124	14041-10000-28180	1575 S WESTWOOD BLVD	90024	5	129B153   133	4324026036	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.05282	-118.43987	Title 24 plan check only. New subpanel, feeder, lighting, receptacles, and instantaneous water heaters for T.I.Non high rise. Area = 4111 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60125	15041-10000-33102	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Info Complete	10/06/2015 12:00:00 AM	ADDRESS	34.07594	-118.35916	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (CBS STUDIO). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AREA IS 3593 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60126	13041-10002-29379	1109 S GLENDON AVE	90024	5	132B153   180	4363022003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	03/11/2016 12:00:00 AM		Issued	03/11/2016 12:00:00 AM	ADDRESS	34.06052	-118.44439	Changes to approved set.  Changes to distribution system.  Instead of being connected to two seperate swithboards, tenant space is receiving its own new service.  Changes to kitchen equipment and HVAC.  New lighting fixtures used.***** Previous Work Description *****    Supplemental to approved set- changes to architecture layout. Plan check for power and energy.  ((T.I. for new restaurant in an (E) 2-story building.  No change of use.  Proposed occupant load in excess of 200 occupants, likely A2 occupancy.  Power and energy.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60127	19041-10000-00498	14715 W ARMINTA ST	91402	6	189B149   475	2210021013	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.21361	-118.45363	FULL PLAN CHECK FOR - CHANGE OF USE FROM A MACHINE SHOP TO A NURSERY SPACE, NO EXTRACTION. TOTAL NEW CONNECTED LOAD IS >400A TO AN EXISTING 800 SERVICE RATED AT 480/277V.  (B# 18016-10000-34293)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60128	16041-20001-07540	140 S RENO ST	90057	13	138A201   373	5155004025	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.07028	-118.28178	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM 1 SIZE: 152.6 KW.TOTAL SYSTEM SIZE: 234 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60129	12041-10000-03443	8500 W BURTON WAY 1-88	90048	5	138B173  1128	4334016087	(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Apartment			03/08/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	04/15/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	Plan check fire alarm system for new 88 unit apartment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60130	15041-30000-40415	10930 W ASHTON AVE	90024	5	132B153   585	4324004038	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.05742	-118.4443	Plan check for fire alarm system in existing 38 unit apartment building.  Replace FACP and add 2 new devices to existing system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60131	13041-10000-16138	921 N HIGHLAND AVE	90038	4	144B185  1094	5532012038	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Closed	11/22/2013 12:00:00 AM	ADDRESS	34.08774	-118.33877	PLAN CHECK FOR FIRE ALARM. 18 DEVICES AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60132	11041-10000-06653	3560 S WATT WAY Lab B-10	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM			PC Info Complete	04/04/2011 12:00:00 AM	ADDRESS	34.02169	-118.28671	title 24 and emergency lighting for laboratory.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60133	14041-20000-14045	170 S LA BREA AVE	90036	5	138B181  1198	5513018016	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.07151	-118.34383	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL STORE. CLOTHING STORE "" I LOVE UGLYS "". 1470 SQFT, EMERGENCY LIGHTING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60134	18041-20001-01171	1942 N SAN YSIDRO DR	90210	5	150B157   163	4384030012	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.10647	-118.42415	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (47) modules, (2) load centers, and (2) PowerWalls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60135	11041-10000-19989	849 E 6TH ST	90013	14	126A213   228	5147016001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Finaled	04/22/2013 12:00:00 AM	PIN	34.04010775	-118.24128342	NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60136	14041-10000-08051	412 N FAIRFAX AVE	90036	5	141B177  1435	5527030018	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.07866	-118.36128	TI in an existing pizza store. EPC is for T24 and emergency lights. (1st time tenant [see 14041-10-07618] - power done under supplemental. fees are under inspection)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60137	16041-10002-25329			15	045B197   144	7347018094	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			09/24/2018 12:00:00 AM			PC Approved	09/24/2018 12:00:00 AM	PIN	33.81538876	-118.29960889	[[[09/24/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. RELOCATING (2) EVSE CHARGERS TO ONE LOCATION. CHANGES HAVE BEEN CLOUDED AS DELTA B ]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60138	18041-10001-25639	2440 S SEPULVEDA BLVD #180	90064	5	123B153   135	4256008***	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM			Corrections Issued	08/13/2018 12:00:00 AM	ADDRESS	34.03617	-118.43421	Plan check for T24 only, TI on (E) warehouse.  Electrical Permit was obtained under 18041-30000-25639.(B# 18016-10000-12008)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60139	16041-10001-30787	5638 N FIGUEROA ST	90042	1	151-5A229 278	5468032018	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.10944	-118.19275	CHANGES TO APPROVED SET. MINOR LIGHTING REVISIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60140	11041-20000-06154	10201 W PICO BLVD BLD. 6	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Expired	05/16/2013 12:00:00 AM	PIN	34.05182951	-118.41257696	T.I. to building 6.  Install high voltage transformer (2.4 KV), panels, and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60141	10041-20000-10337	6911 N HAYVENHURST AVE	91406	6	183B137   350	2225002002	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM			PC Approved	06/02/2010 12:00:00 AM	ADDRESS	34.1961	-118.49263	Plan check only for office t.i. energy. Permit under #10041-90000-09722	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60142	16041-10002-25220	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Approved	04/17/2017 12:00:00 AM	ADDRESS	34.20615	-118.41279	Supplementary PC for downsized breakers from 2000A to 1200A  for distribution boards DB2 and DB1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60143	16041-10001-23440	20040 W VENTURA BLVD	91364	3	174B113   598	2166043006	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.171	-118.56999	08/18/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include removing/adding new lighting fixtures on the lighting floor plan.Note: Original application is under PCIS#16041-10000-23440((((PC FOR RESTAURANT TI. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60144	13041-20000-19172	3584 S FIGUEROA ST GND FLOOR	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	T24 FOR EXISTING MIXED USE BUILDING. SCOPE OF WORK IN THE GYM AREA ON THE GROUND FLOOR. TOTAL SQRFT 4224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60145	10041-20000-01816	4302 N EAGLE ROCK BLVD	90041	1	156A219   100	5474022009	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1862.01	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Issued	06/15/2010 12:00:00 AM	ADDRESS	34.12254	-118.22318	Infrastructure Upgrade	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60146	16041-10000-45536	1501 S RIO VISTA AVE	90023	14	120A219   219	5169010***	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.02301	-118.22307	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures for interior and exterior lights. Total affected area is 13250 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60147	19041-10001-01690	1707 W 265TH ST	90710	15	030B193    79	7411028025	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	33.78107	-118.30745	EXPEDITE PER APPLICANT REQUEST. (((PV1. NEW SOLAR SYSTEM WITH STORAGE BATTERY ON EXISTING RESIDENTIAL HOME. TOTAL SYSTEM SIZE IS 8.96Kwdc / 7.6KWac. TOTAL STORAGE BATTERY 9.8KWH LG CHEM RESU10H  (28)MODULES-PANASONIC GROUP VBHN320KA01(28)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE7600A-USS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60148	17041-20001-15179	222 E 16TH ST	90015	14	123A207    57	5133015010	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Issued	12/07/2017 12:00:00 AM	ADDRESS	34.03253	-118.26099	11/29/2017 Changes to an approved set of plans. The second floor layout has been revised and now includes low-partition offices and now includes new circuits for power. All lighting has remained the same.*****Previous Work Description*****Tenant improvements for future move-in.  New 800A 240V 3ph-4w service and distribution.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60149	14041-10000-00829	5104 N DENNY AVE	91601	2	171B177  1008	2419011027	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Apartment			01/10/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.16293	-118.36469	PV2, SOLAR INSTALLATION ON A NEW SUPPORT STRUCTURE ( 349 SF ) WITH INSTALLATION OF (1) PHOTOVOLTAIC SUPPORT STRUCTURE AND ELECTRICAL FOR PV INTERCONNECTION TO EXISTING SITE ELECTRICAL SWITCHGEAR THE NEW STRUCTURE WILL BE FEEDING BLDG #1 (2-STORY, 4 UNIT) AND BLDG  #2 (2-STORY, 5 UNIT) VIA UNDERGRND, TRENCHED. SYSTEM SIZE IS 5kW DC & IS TRANSFORMERED WITH (20) TRINA SOLAR TSM-250 PA05.08 . (2) INVERTERS @ 2kW EACH.   BUILDING PERMIT: 14010-10000-00070; NO SOLAR CLEARANCE ADDED DUE TO PLANS ALREADY BEING SUBMITTED TO BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60150	18041-10000-03227	1875 CENTURY PARK EAST # 480	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	PIN	34.06139196	-118.41527843	Plan check for T.I. office high-rise building install new lighting fixtures, lighting control devices and receptacles. Provide power to the new lighting fixture and recepatcle. Total aera: 2570 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60151	09041-10001-11227	2600 W WILSHIRE BLVD	90057	1	133-5A201 122	5141008900	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	04/08/2011 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.06041	-118.28167	Plan check power and energy for installation of new panels, circuits, emergency generator, and emergency equipment.     PLANS CHANGES ARE AS FOLLOWING: ADDITION OF 235 NEW BRANCH CKTS, TWO NEW EMERGENCY PANEL BOARDS, 1 NEW NORMAL PANEL, NEW EMERGENCY DISTRIBUTION SE PAGE  E0.2C . ADDTION OF NEW TITLE 24 AREA.FUTURE  FIRE PUMP UNDER SEPARATE PERMIT WITH VARIANCE AND FIRE WATCH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60152	16041-10000-28026	12424 W WILSHIRE BLVD STE 600	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.04135	-118.47058	T-24, PC FOR ENERGY ONLY.TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 6TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 4195 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60153	17041-20002-18229	17638 W RAYMER ST	91325	12	192B129    51	2787029005	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM			Corrections Issued	07/20/2017 12:00:00 AM	ADDRESS	34.22646	-118.51894	Plans lost - review of previously approved set.  (((Plan check for solar pv sysetm, roof-mounted on SFD.10kW ungrounded sysetm. (40) 330W pv modules.Each module has a 400W power optimizer.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60154	18041-10000-10921	3344 N CHAPMAN ST	90065	13	156B213   267	5459009026	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.12184	-118.24278	REEPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60155	18041-20000-35454	314 S GLENROY AVE	90049	5	135B145    63	4366020008	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.06999	-118.46033	13.5 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60156	19041-20000-06378	17138 W SESNON BLVD	91344	12	225B133   214	2602003025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.30995	-118.50644	PV1.  Install 8.64 kW roof mounted grid tied PV system with 9.8 kWh energy storage system.  (27) modules with 7.6 and 3.8 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60157	16041-30000-17257	10643 W SUNSET BLVD	90077	5	138B153   103	4362009012	A1-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.07571	-118.44485	Plan check for Title 24 only. Project site is an existing private high school. Project scope is a tenant improvement. Total lighting area = 6,943 sq. ft.Note: Building application has been created under 16016-30000-05732	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60158	10041-20000-01115	12445 N GLADSTONE AVE	91342	7	219B161   245	2525018058	M1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM	01/21/2010 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.2961	-118.41248	"ADD 1,163 SQ FT TO 2nd FLOOR OFFICE & CHG OF USE 3,133 SQ FT PORTION FROM OFFICE TO RETAIL""Comply with Department order effective 05/08/2007.Permit will expire 30 days from issuance date"".(See comments).ENERGY ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60159	17041-20000-14874	5900 W WILSHIRE BLVD ste 2100	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.06237	-118.35809	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60160	15041-10000-35601	20504 W ESMERELDA LANE	91326	12	216B109   201	2701082002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/05/2016 12:00:00 AM	ADDRESS	34.2906	-118.58027	PV1INSTALL ROOF MOUNTE PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60161	13041-10000-28798	19028 W FRIAR ST	91335	3	177B121    34	2128007005	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.18555	-118.54788	PV1. ROOFMOUNTED PHOTOVOLTAIC SYSTEM. SYSTEM SIZE : 3.5KW. TRANSFORMERLESS WITH (14) HANWHA #HSL60P6 AND (1) SOLAREDGE # SE 3800A, POWER OPTIMIZER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60162	17041-10000-35413	11350 W VICTORY BLVD	91606	2	180B173   917	2336015017	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Issued	10/03/2017 12:00:00 AM	ADDRESS	34.18652	-118.37857	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 10800 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60163	18041-10001-23888	5651 W MANCHESTER AVE 1ST Floor	90045	11	096B169   254	4125001901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	33.96006	-118.37965	CHANGES TO APPROVED SET OF PLAN CHANGES INCLUDE MODIFICATION OF LIGHTING SEE LIGHTING FIXTURE SCEHDULE AND LIGHTING PLAN CHANGE OF USE TO CONVERT EXISTING CAFETERIA AND DINING ROOM TO A LIBRARY ON THE FIRST FLOOR. T-24 ENERGY ONLY. BLDG PERMIT: 17016- 10000-21712	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60164	12041-20000-04738	21501 W ROSCOE BLVD	91304	12	192B105   592	2779036021	C2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Apartment			03/01/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.21994	-118.59892	81 unit (3) story plus loft level apartments over basement garage parking.  Parallel Design-Permitting Program 30% submittal, zoning only, no green, no disabled, no life-safety, no structural.variance for fire alarm on file	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60165	18041-10000-14863	100 W WORLD WAY 1.5-P/C	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	02/26/2021 12:00:00 AM	PIN	33.94684048	-118.40128468	PC FOR POWER AND ENERGY FOR NEW 4 LEVEL MIXED USED  (WITH BASMENT) ADDITION TO TERMINAL 1. NEW 2 SERVICES MEDIUM VOLTAGE 4160VTOTAL AFFECTED AREA 246804B#17014-10000-06579	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60166	16041-10000-08429	1148 W 56TH ST	90037	9	108B197  1033	5002020003	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	33.99129	-118.29542	PV1, rooftop solar installation 5kWac system.    (19) CS6P-265P    (1) SE5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60167	10041-20000-05514	8389 W 3RD ST	90048	5	138B173   747	5511015015	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	03/25/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	ADDRESS	34.07313	-118.37295	installing lighting and receptacles. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60168	15041-20000-02870	9733 N DANUBE AVE	91343	12	201B141   329	2671004011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.24736	-118.47522	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 100A MSP.System size: 3.84kW. Ungrounded system.(16) EnPhase M250 Microinverters(16) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60169	15041-10000-10037	7220 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	33.97413	-118.2913	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 18034	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60170	16041-30000-20843	19621 W WELLS DR	91356	3	171B117   310	2164020019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.16419	-118.56108	Plan check for a PV1 roof-mounted PV system. System size is 18.2 kWac and consists of (3) inverters, (90) modules, (2) combiner boxes, and (1) load center.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60171	14041-20000-18651	9427 N COLLETT AVE	91343	12	198B141   156	2671015015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Expired	08/24/2016 12:00:00 AM	ADDRESS	34.24177	-118.48403	PV1 10.2 roof-mounted system with (40) trina Solar TSM-255p modules and Solaredge p300 optimizers, (2) inverters se3800A and SE6000A connecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60172	14041-20000-33496	16128 W LONDELIUS ST	91343	12	195B141   651	2672026010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	34.2292	-118.48383	PV1 SFD. TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER SYSTEM. ENPHASE M215. USING STANDARD PLAN. TOTAL OF 16 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60173	17041-20000-43860	640 E 40TH PL	90011	9	115-5A207 331	5114007022	RD2-1	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	Apartment			12/06/2017 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.0101	-118.26445	Plan check for power and energy. Change of use from manufacturing to 6-unit apartment. New 600A 120/240V 1ph 3w service. T24 area: indoor-665sqft; outdoor-5,490sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60174	16041-20000-45116	1510 W 228TH ST	90501	15	045B193   413	7347017010	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	33.8189	-118.30418	TI to (E) commercial office/warehouse space.  Plan check for energy.  COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 9/26/16 PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. REFER TO CASE NUMBER 735539	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60175	13041-20000-07407	515 S FLOWER ST 2601	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for energy and emergency lighting. 26th floor. Room 2601.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60176	18041-20000-15279	11835 W OLYMPIC BLVD 2nd Floor-Corridor	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Issued	04/25/2018 12:00:00 AM	ADDRESS	34.03301	-118.45119	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,597 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60177	14041-20000-25416	4710 N BIZET PL	91364	3	168B097   396	2074027036	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.15685	-118.62638	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(25) SolarEdge P300 power optimizers(25) Kyocera KD255GX pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60178	19041-20000-06858	8700 S PERSHING DR PV2	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	07/11/2021 12:00:00 AM	ADDRESS	33.95471	-118.44097	PV2.  Install 122.64 kW DC / 112.06 kW AC roof mounted grid tied PV system.  (336) modules with (4) 30 kW rated string inverter.  Interconnecting with MSA-2.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60179	11041-10000-14978	8575 W 3RD ST	90048	5	138B173   619	4334006019	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.07372	-118.37914	Photovoltaic system raised above parking deck on canopies.  T-24 and emergency lighting plan check approved on separate plan and application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60180	15041-10001-08300	13421 N BORDEN AVE	91342	7	225B149   113	2502030002	RA-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.31597	-118.45449	Expedite per customer request.(((PV1 6.0KW roof-mounted system with (21) Sunpower SPR-327 modules and (1) SMA America SB 6000TL inverter interconnecting through a subpanel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60181	11041-20000-04675	623 S LINCOLN BLVD	90291	11	111B145   846	4240016054	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM	05/27/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	33.99971	-118.46485	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR RESTAURANT TI IN 1 STORY BUILDING. NEW 400A SERVICE. INSTALLATION LESS THAN 400A LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60182	18041-20000-00048	7624 N WINNETKA AVE	91306	3	186B113   126	2106006034	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.20904	-118.57081	TENANT IMPROVEMENT OF AUTO REPAIR SHOP DUE TO FIRE DAMAGE.  EXISTING 200A 240/120V ELECTRICAL SERVICE.BUILDING PERMIT #  17016-20000-31184	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60183	13041-10001-23362	446-450 S MAIN ST	90013	14	129A211   140	5148009012	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.0471	-118.24791	DELTA 2 CHANGES TO APPROVED SET.(APPROVED SET SUBMITTED FOR REFERENCE.)ADDING TWO 75 KVA TRANSFORMERS AND 1 NEW PANEL WITH CIRCUITS.{{{Full plan check power and energy for renovation of theater. New service size 800A. Total new load 740A.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60184	15041-20000-12760	16627 W NORDHOFF ST	91343	12	198B137   972	2687024005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.23588	-118.4948	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 15 kWac.  3 inverter system.NOTE: Permit fee is $0.00 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60185	18041-10000-47229	1224 S PACIFIC AVE	90731	15	015B197  1464	7456008002	C2-1XL-CPIO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.73298	-118.28777	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60186	16041-20001-21226	10346 W DIAMOND ST LOT 14	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60187	15041-20000-06917	15910 W VENTURA BLVD 900	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.15561	-118.47969	Plan check for T-24 only for office space highrise. Total area: 700 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60188	16041-10000-09347	12659 W TERRA BELLA ST	91331	7	207B161   222	2536014062	RS-1	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.26508	-118.40872	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.42KWdc / 3.655KWac.(17)MODULES-HANWHA Q.PRO BFR G4-260(17)MICROINVERTERS-ENPHASE M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60189	11041-10000-15404	9901 N DRONFIELD AVE	91352	2	201B173   181	2538024901	OS-1XL-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	05/29/2012 12:00:00 AM	ADDRESS	34.24936	-118.37489	CHANGE TO LIGHTING FOR A GYMNASIUM AND PARK AREA.  PLAN CHECK IS FOR INDOOR AND OUTDOOR LIGHTING.  ENERGY ONLY. PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60190	16041-10001-44009	10250 W SANTA MONICA BLVD # 1580	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	2/7/17: Changes to approved set, updated panel schedule and T24 forms due to :(1) added track light and its circuit, L-4;  (2) added insta hot heater and its ckt, L-40.  Changes are noted under delta 3 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60191	12041-20000-14493	14531 W VENTURA BLVD	91403	4	166-5A151 101	2265010022	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.15126	-118.44977	T.I. to existing building (Restaurant).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60192	10041-10000-04766	5517 S HOLMES AVE	90058	9	108B213   309	5105012029	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM			PC Info Complete	02/07/2011 12:00:00 AM	ADDRESS	33.99244	-118.24133	INSTALL A NEW 5KW PV SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60193	15041-20000-08618	3732 S CIMARRON ST	90018	8	117B189   184	5042013002	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.02008	-118.31543	Plan check for a PV1 roof-mounted PV system. System size is 4.3 kWac and consists of (20) modules, (20) micro-inverters, and (1) 100 amp-rated subpanel. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60194	16041-10001-07724	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	33.98489	-118.42552	09/15/16Changes to an approved set of plans. All changes are made under delta 2 & 3. Changes include replacing the AIC rating for the 1600A disconnect switch from 100AIC to 65AIC, revising data feedback controls, and adding ground fault protection sensors.Note: permit is paid under PCIS#16041-10000-07724((((((PROPOSE TO INSTALL CLEAN ENERGY SERVERS 4 - 250KW ES 5 ON A PRECAST PAD OF THE DIRECT TV WITHIN (E) PARKING LOT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60195	10041-10000-12161	2431 N BOWMONT DR	90210	5	153B165   142	4388011022	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	34.11706	-118.39766	REMODEL OF SINGLE FAMILY HOUSE. SERVICE UPGRADE TO 600 AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60196	13041-10001-35300	5842 N COSTELLO AVE	91401	2	174B153   122	2246014002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2013 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.17697	-118.43765	expedited per applicants requestPv1, Install 7 kw DC roof-mounted solar array for a one story building,(28) Renesola JC250M-24/Bb solar modules,(1) Solaredge SE6000A-US inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60197	14041-10000-27468	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	PIN	34.05243427	-118.25124731	PLANCHECK FOR T24 ENERGY. NO CHANGE IN OCCUPANCY. RESTAURANT.  1164 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60198	17041-10000-01519	13546 W DESMOND ST	91331	7	210B157    87	2523005006	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			Reviewed by Supervisor	02/23/2017 12:00:00 AM	ADDRESS	34.27517	-118.42768	PC FOR POWER. SERVICE UPGRADE FOR A INDUSTRIAL BUILDING FROM 200A TO 1200A. THE PLAN INCLUDES TWO BUILDINGS , THE MAIN  BUILDING ADDRESS IS 13546 DESMOND ST THAT INCLUDES MAIN 500A SERVICE.(17041-10000-.01514)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60199	15041-20000-01527	7012 N LONGRIDGE AVE	91605	2	183B157   469	2327006065	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.1978	-118.4213	PV1. Install roof mounted PV system sized (30) Sunpower SPR-327NE Modules(1) Sunpower IG Plus Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60200	13041-10001-24726	1870 N BURNELL DR	90065	1	148-5A217  58	5455006021	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	ADDRESS	34.10292	-118.23147	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60201	16041-10000-36266	10250 W SANTA MONICA BLVD # 1840	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time tenant Tenant ""Ted Baker"" Ste. 1840.  Install new Xrfmr, and  panels, total area 3000 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60202	14041-10000-29867	722-736 E WASHINGTON BLVD	90011	9	121-5A209 156	5131006005	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Apartment			10/28/2014 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.02718	-118.2568	FULL PLAN CHECK FOR NEW 4 STORY MULTI-FAMILY BUILDING WITH  55 APARTMENT UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60203	16041-20000-42424	12385 N SAN FERNANDO ROAD #37	91342	7	219B149   648	2611007050	(T)(Q)RAS3-1-CPIO, C2-2D-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.29518	-118.45448	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60204	13041-10000-25596	6820 S BRYNHURST AVE	90043	8	102B185   578	4006023003	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	33.97624	-118.33366	TITLE 24 PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALL NEW FLUORESCENT FIXTURES. 11,163 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60205	13041-20000-23656	1585 W OAKHORNE DR	90710	15	042B193   153	7438003013	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	33.81338	-118.30556	PV1 MICROINVERTER. TOTAL SYSTEM SIZE 2.36KWAC. 11 MODULES AND 11 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60206	11041-10000-18023	516-522 S MAIN ST	90013	9	129A211   226	5148019008	C2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Finaled	08/24/2012 12:00:00 AM	ADDRESS	34.04616	-118.2488	REMOVE EXISTING SERVICES AND REPLACE WITH A 800A SERVICE AND RECONNECT SOME LOADSON SITE, THERE ARE TWO BUILDINGS ABUTTING EACH OTHER WITH TWO OPENINGS BETWEEN THE BUILDINGS (SEE 11016-10000-16702). THIS THEN FORM ONE TENANT SPACE . EXISTING SERVICE IN 516 BUILDING WITH PANELBOARDS SERVING LOADS IN THAT BUILDING. 518 - 522  BUILDING WILL HAVE THE NEW 800A SERVICE WITH ITS PANELBOARDS SERVING LOADS IN THAT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60207	19041-20000-14616	5555 W MELROSE AVE Power-House 2	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.08363	-118.32191	Medium and low voltage distribution equipment replacement for (E) commercial studio facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60208	17041-20001-28268	9333 N MELVIN AVE	91324	12	198B117   121	2761036046	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.24024	-118.56026	11-06-2018 Changes to an approved set of plans, Changes include service upgrade to 800A . loads are to remain from master plan set. all changes apply to clouded area only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60209	14041-20000-16686	20634 W CLARENDON ST	91367	3	174B109   560	2151030054	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	34.17096	-118.58263	PV1Install roof-mounted solar array on SFD. System size: 5kW(1) SolarEdge #SE5000A-US-ZB-U transformerless inverter(18) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60210	11041-10000-11644	21730 W SHERMAN WAY	91303	3	183B105   151	2111025002	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM			Corrections Issued	06/26/2011 12:00:00 AM	ADDRESS	34.20086	-118.60267	CHANGE OF USE FROM RETAIL TO RESTAURANT IN EXISTING SINGLE STORY BUILDING.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60211	14041-20000-30121	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Closed	07/25/2018 12:00:00 AM	ADDRESS	34.0965	-118.30717	Plan check for power only. 600A temporary power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60212	13041-20000-28238	12902 W FOOTHILL BLVD C	91340	7	219B161   299	2514002058	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	34.29368	-118.41576	Change of use from market to restaraunt.  Occupancy load is less than 99 and less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60213	12041-10000-21491	1925 S CENTURY PARK EAST	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.06066	-118.41426	TI in an existing office, EPC is for T24. (suite #1050) 5147 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60214	14041-10000-30532	639 N BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Apartment			11/04/2014 12:00:00 AM			PC Info Complete	01/27/2015 12:00:00 AM	PIN	34.05985996	-118.23998637	TENANT IMPROVEMENT IN EXPRESSBANK IN CHINATOWNPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60215	18041-20001-48715	8600 W LA TUNA CANYON ROAD	91352	7	198B189   116	2401028***	A1-1XL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.23699	-118.3204	Expedite per applicant request Plan check for PV roof mounted system, system size: 21.6kW DC, 18.3kW AC with 60 PV Modules and 2 inverters(11.4kW and 7.6kW) connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60216	15041-10000-08610	19377 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.18773	-118.5556	Energy plan check for retail T.I. total area is 1699-SQ feet with Tailor Method.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60217	19041-10000-23256	1921 S VIRGINIA ROAD	90016	10	126B185  1052	5061005003	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Refund in Progress	02/24/2020 12:00:00 AM	ADDRESS	34.03929	-118.33577	PV1 rooftop solar system 10kW AC. Install (34) modules with (34) P320, (1) 10kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60218	13041-10000-32970	22774 W MACFARLANE DR	91364	3	171B097   948	2075017030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.16176	-118.62296	PV1, Install  12.5 kw DC roof-mounted solar array for a  house interconnect with service panel.(2)Transformerless inverters: SOLAREDGE SE6000-US and SOLAREDGE SE5000-US . 50 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60219	14041-20001-30341	4520 N WOODLEY AVE	91436	5	168B141   757	2283012032	RE15-1-H	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2014 12:00:00 AM			PC Approved	11/25/2014 12:00:00 AM	ADDRESS	34.15394	-118.48338	DISREGARD APPLICATION. PV1 SFD. TOTAL SYSTEM SIZE 18KW AC USING 72 MODULES. USING MICROINVERTER SYSTEM. MICROINVERTER ENPHASE M250. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60220	19041-10000-23799	10330 W ROSSBURY PL	90064	5	123B161    31	4318026009	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.03722	-118.40964	(ePlan) PV1  Roof mounted solar 7.6 kW system. Install (20) modules with (20) P400 optimizers, (1) 7.6 kW Inverter. PV connects to (N) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60221	13041-20000-35357	2996 S SEPULVEDA BLVD #300C	90064	5	120B157   219	4251003033	C2-1VL	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.02758	-118.42857	Tenant improvement / interior remodel to an existing office space to Suite #300C. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60222	13041-20002-10101	5700 N CANOGA AVE flr 5	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM			PC Info Complete	07/23/2013 12:00:00 AM	ADDRESS	34.17365	-118.59715	"((supplemental application for changes to approved set of plans. changes clouded delta 1. a couple new circuits and changing lighting. ))))Full plan check for commercial. Addition to an existing building (addition is to 5th floor). highest floor is 5th floor. Addition of ""optional"" 750kW generator (other 750kW generator existing). Viking River Cruises. Not methane zone. PC fees per applicant."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60223	11041-20000-17200	6430 W SUNSET BLVD #475	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.09782	-118.32979	office t.i.Energy, emergencyFire/ Life safety by others	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60224	18041-10000-31639	900 W ANAHEIM ST	90744	15	030B205   502	7416016002	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	33.77923	-118.27312	remove outdoor HID fixtures and replace with new LED fixtures. T/24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60225	19041-10000-50591	1218 W 51ST ST	90037	9	111B197  1311	5017009010	R1R3-CPIO	South Los Angeles	South Los Angeles	Voices		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.99676	-118.29666	NEW PV1 INSTALLATION USING 10 SLA-M-300 DC MODULES, 10 SE P320 POWER OPTIMIZERS & 1 SE3000H-US CENTRAL INVERTER. SYSTEM SIZE 3 KWdc(3KWac).CONNECTED TO A 200Amp EXITING SERVCE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60226	16041-20000-37020	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.10311	-118.31242	Plan check for a PV2 roof-mounted PV system. System size is 36 kWac and consists of (4) inverters, (144) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60227	18041-20000-48151	9225 N RESEDA BLVD	91324	12	198B125   229	2763009035	C1-1L, P-1VL	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.23795	-118.53628	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60228	19041-20001-29446	625 E COLEMAN AVE 2 of 2	90042	14	148-5A231   3	5301011029	[Q]RS-1D	East Los Angeles	Northeast Los Angeles	Hermon	YES	2013.02	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	09/05/2019 12:00:00 AM	ADDRESS	34.10231	-118.18265	expeditepv3install roof mounted pv system sized 21.4KW AC interconnecte with msp.this is system 2 of 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60229	10041-10000-00751	5757 W WILSHIRE BLVD #M100	90036	4	135B177   470	5508015004	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	03/16/2010 12:00:00 AM		Permit Finaled	06/25/2010 12:00:00 AM	ADDRESS	34.06259	-118.35341	Tenant improvement for high rise building.  Install new panel, branch circuits, and general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60230	19041-20000-48382	5242 N TOPEKA DR	91356	3	171B121   286	2161004011	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.16591	-118.54644	PV1.  Install 10.31 kW AC CEC roof mounted grid tied PV system.  (36) modules with 10 kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60231	16041-10000-43043	700 W 7TH ST Flower St-Restrooms	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC AND PERMIT FOR RESTROOM REVISION, HALL AND STAIR UPGRADE TO FLOWER ST ENTRANCE. THIS SCOPE WAS ORIGINAL PART OF ANOTHER PERMIT. PER BUILDING, A DIFFERENT CONTRACT WAS PROVIDED FOR THIS SCOPE. RE-PLAN CHECKING FOR ENERGY COMPLIANCE ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60232	16041-20000-26716	1155 N ANGELO DR	90210	5	144B157   353	4358009008	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.08979	-118.43217	Plan check for SFD 1,200 A Service with backup 60kW generator	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60233	13041-10000-26092	1947 W 85TH ST	90047	8	097-5A193 193	6035026011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	33.96101	-118.3128	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 7.35 KW DC. STANDARD PLAN.(30) MODULES: YINGLI #YL245P-29B(1)INVERTER: FRONIUS # IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60234	11041-10000-06063	6111 E MESA AVE	90042	1	154-5A229 315	5484017018	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	Apartment			03/29/2011 12:00:00 AM			Reviewed by Supervisor	06/02/2011 12:00:00 AM	ADDRESS	34.11607	-118.1907	INSTALL 2.16 KW (DC) PV SYSTEM ON EXISTING APARTMENT BUILDING.  INSPECTOR HAS REQUESTED PLAN CHECK IN THE FIELD.  (REGULAR PLAN CHECK PER APPLICANT REQUEST.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60235	18041-20001-15443	4981 N BILMOOR AVE	91356	3	171B117   489	2175010011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.16161	-118.55961	Revisions to approved set.  Addition of performance meter and relocation of equipment.  $0 plan check fee per State Senate Bill SB 1222.(((pv1install roof mounted pv system sized 15.2kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60236	16041-10000-23038	977 S ARAPAHOE ST	90006	1	130-5A201  73	5076005011	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.05316	-118.28555	PERMIT FEES IS $0 per senate bill  1222.******************************************************************************* PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.88KWdc / 11.0KWAC.(46)MODULES-HYUNDAI HIS-S280RG(1)INVERTER-FRONIUS PRIMO 5.0(1)INVERTER-FRONIUS PRIMO 6.0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60237	10041-10000-20588	12200 W OLYMPIC BLVD	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	05/09/2011 12:00:00 AM	ADDRESS	34.03195	-118.45506	in a data processing building, UPS system and CRAC units supplied from nearby  site ( 12312 W Olympic Blvd )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60238	18041-10002-36986	13101 W WELBY WAY	91606	2	180B161   126	2326010008	R1-1	South Valley				1234.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.19308	-118.41838	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE CHANGE OF MODULE TYPE AND REMOVAL OF MODULES. TOTAL SYSTEM SIZE IS 10KVA AC/ 9KWDC / 8.111KW AC RATING .MISC. PERMIT FOR CHANGE OF DESCRIPTION. _______________________________________Install new PV1, rooftop solar system in (E) SFD. System size at 10.890 kW DC / 10 kW AC. Scope includes: (33) modules with (33) optimizers P400, (1) SE10000 central srting inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60239	13041-20000-26682	21240 W BURBANK BLVD 2nd floor	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	10/04/2013 12:00:00 AM	ADDRESS	34.17307	-118.59314	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. NEW LIGHTING. TOTAL AREA 40000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60240	17041-20001-34095	10324 N MT GLEASON AVE	91042	7	204B193   562	2558006002	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Apartment			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.25663	-118.30252	12-13-2019 Changes to an approved set of plan, changes include relocate service equipment, revised unit rating of circuit breakers, new outdoor lighting and inside unit lighting, revised outdoor Title 24 calculation. All changes has been clouded as delta 2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60241	17041-20000-02122	16120 W DEARBORN ST	91343	12	198B141   581	2671021003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.23739	-118.48366	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (33) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60242	19041-10000-32184	19525 W NORDHOFF ST	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	08/28/2020 12:00:00 AM		Permit Finaled	02/02/2021 12:00:00 AM	ADDRESS	34.23567	-118.5584	Full plan check for a first time tenant (new restaurant) to an exisiting shell space. Scope of work inlcudes an existing 1600A service (208/120 three phase) ,an exisiting main switchboard,  and four new subpanels. Total affected area is 2974 sqft. Note: Final fees to be adjusted by plan checkerB#: 19016-10000-25765	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60243	14041-20000-10786	22627 W CALIFA ST	91367	3	177B097   612	2040003006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.17751	-118.61981	PV1 SINGLE FAMILY. ROOF MOUNTED PV SYSTEM 7.2 KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. 36 MODULES. USING 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60244	16041-10000-30331	8 S CHESTER PL	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Info Complete	03/23/2017 12:00:00 AM	ADDRESS	34.03102	-118.27718	TI TO OFFICE/ MUSEUM - PC FOR T24 ENERGY ONLY FOR NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60245	15041-20001-11919	5695 S GOLDENEYE CT UNIT 3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	33.97898	-118.41086	Expedite per applicant request*********Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL BE RELAVENT TO UNIT # 1 OF ADDRESS 5695 GOLDENEYE CORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60246	14041-10000-32774	740 S OLIVE ST #104	90014	14	127-5A209  18	5144013034	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Expired	01/11/2017 12:00:00 AM	ADDRESS	34.04537	-118.25644	New tenant (H&R Block) with 200-Amp panel. Electrical Inspector to verify the size of 800Amp 120/208, 3Ph Service, and there are no connected load to feeders 6 & 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60247	16041-20000-05740	17427 W NAPA ST	91325	12	195B129   536	2787026051	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM			Reviewed by Supervisor	03/03/2016 12:00:00 AM	ADDRESS	34.22691	-118.51387	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (39) modules, (2) combiner boxes, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60248	11041-20000-24771	1465 E 103RD ST	90002	15	090B209   480	6048012026	PF-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Closed	06/14/2012 12:00:00 AM	ADDRESS	33.94344	-118.24872	Install new ups in learning center building.  Adding a few receptacles, panel.  No lighting is being added or altered.  Plan check is for power only.  Not a medical facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60249	15041-20000-37308	10046 N SAMOA AVE	91042	7	202-5A199  24	2568006036	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.25157	-118.28721	Plan check for power and energy for a new 3-story, 48-unit apartment building (1 level of below-ground parking with 3 levels of residential). Service size is 2,000 amps. Total indoor lighting area = 33,183 sq. ft. and outdoor lighting area = 9,000 sq. ft.Note: Building application has been filed under application number 11010-10000-01574 and was submitted on 07/2011	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60250	14041-10000-25849	1465 E 103RD ST	90002	15	090B209   480	6048012026	C4-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	33.94344	-118.24872	Title 24 for a office T.I., lighting retrofit from existing fixtures to LED retrofit kits. total remoding area covers 11,034 SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60251	10041-10002-05199	633 S MISSION ROAD	90023	14	124-5A219   3	5171015001	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM			PC Approved	06/14/2010 12:00:00 AM	PIN	34.0373651	-118.22637397	REVISED SINGLE LINE DIAGRAM SHOWING THE FEEDERS TO PANEL HA2 AND TO PANEL LA3 ARE ALUMINUM CONDUCTORS ; VOLTAGE DROPS  REVISED ;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60252	16041-30000-39635	845 N VIA DE LA PAZ 2nd FL	90272	11	129B125   735	4412004022	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	02/15/2017 12:00:00 AM	ADDRESS	34.04609	-118.52754	Plan check for Title 24 only in existing space office building. Total area: 1,855 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60253	15041-20000-13999	8560 N AQUEDUCT AVE	91343	12	192B141    73	2673012038	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Expired	05/10/2017 12:00:00 AM	ADDRESS	34.2263	-118.47413	Installation of new roof mounted solar PV array.  Total system size = 9.6 kWac.  System has two central inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60254	16041-20000-06449	8138 N FAIRCHILD AVE	91306	3	189B109    17	2108031001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	PIN	34.21831306	-118.58750569	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (13) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60255	14041-20000-22433	11414 W HATTERAS ST	91601	2	174B169   310	2338024014	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			08/19/2014 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.17553	-118.37969	THREE STORY TYPE V-A 14 UNIT APT W/ 1ST FLOOR GARAGE.  BLDG PERMIT FILED BEFORE JULY 1ST - ENERGY WILL BE UNDER 2008 CODE CYCLE.  POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60256	10041-20000-01162	2159 W STRATFORD CIR	90049	5	150B141   108	4377049003	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2010 12:00:00 AM	03/25/2011 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.10833	-118.47463	NEW 2 STORY SFD WITH BASEMENT GARAGE and 600A service. 1ST FLOOR: GARAGE, STORAGE, 605 SF AND HABITTABLE ROOMS (4646 SF). 1ST FLOOR: 4962 SF AND 2ND FLOOR: (4084 SF) - Electrical permit was obtained under the combined building permit number 04010-20000-05494) on 3/6/08.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60257	19041-20000-29495	7956 N GLADE AVE pv1	91304	3	189B101   288	2012012011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.21534	-118.60806	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60258	13041-20000-10887	5023 N STERN AVE	91423	2	171B153   735	2269005013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.162	-118.43468	micro invereter solar single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60259	18041-10000-06202	8985 W VENICE BLVD UNIT C-1A	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			PC Info Complete	02/20/2018 12:00:00 AM	ADDRESS	34.02733	-118.39241	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING LIGHTING FIXTURES. TOTAL AFFECTED AREA IS 4225 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60260	12041-10000-18547	13277 W VAN NUYS BLVD BLDG D	91331	7	207B157   309	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.26583	-118.42276	"CHANGE OF USE FROM WAREHOSUE TO RETAIL AND RESTAURANT; INTERIOR & EXTERIOR REMODEL .  BUILDING ""D"".   FULL PLAN CHECK FOR SHELL ONLY IN A METHANE ZONE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60261	13041-20000-18508	17330 W CLARK ST	91316	5	171B133    71	2257009018	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.16849	-118.51109	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.89KW USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 34 MODULES TOTAL.  PERMIT IS FOR PV SYSTEM ONLY, NOT FOR SERVICE UPGRADE OR DERATING THE MAIN BREAKER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60262	17041-10000-46540	432 N HARVARD BLVD	90004	13	141B193  1488	5521024004	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.0786	-118.30446	PC for 2.760kW rooftop solar for SFD. Installing 12 modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60263	13041-10000-16949	7528 N KRAFT AVE	91605	6	186B169   384	2316010026	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.20742	-118.38001	PV-1 Plan check for 11.5KW roof mounted photovoltaic system. Ungrounded system using Power-One inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60264	19041-20000-15116	1843 S MESA ST	90731	15	012B201   785	7456029036		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	33.7271	-118.28594	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60265	14041-10000-02265	8500 W BEVERLY BLVD LEVELS 1,-6, 7 & 8	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	THE SCOPE IS COMPRISED OF LIMITED RENOVATION, INCL. CHANGE IN USE FROM FOOD COURT TO RETAIL TO AN (E) 8-STORY MALL & INCLUDES:  RECONFIGURATION OF THE 8TH LEVEL INCLUDING (N) PUBLIC TOILETS, WHITE-BOXING OF A FUTURE TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60266	10041-10000-17370	5040 S WESTERN AVE	90062	8	111B193  1307	5016036045	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			09/01/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Closed	01/06/2011 12:00:00 AM	ADDRESS	33.99701	-118.30867	Fire warning system for a two- stories adult day care center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60267	10041-10000-08551	10250 W SANTA MONICA BLVD #154, #155	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	New restaurant in Century City Mall. Unit # 154 & 155. Plan Check is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60268	16041-30000-31128	1672 S STAUNTON AVE	90021	14	120A213   392	5167003035	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.02104	-118.24141	Plan check Title 24 only in existing space T.I., remove outdoor HID lighting fixtures and replace with new LED lighting fixtures. Total area: 2,400 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60269	18041-10000-27452	1000 N NORTH MAIN ST	90012	1	135A217   177	5409009006	UC(CA)	Central	Central City North			2060.10	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	05/13/2020 12:00:00 AM		Permit Finaled	06/24/2021 12:00:00 AM	ADDRESS	34.06285	-118.23379	Plan check for New Methane mitigation/detection sysem.  (1) Control panel, (21) devices(B# 17010-10000-04084)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60270	14041-20001-12992	9119 N CREBS AVE	91324	12	198B121   762	2763021054	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.236	-118.54429	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60271	13041-20000-20861	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/05/2013 12:00:00 AM			PC Approved	08/05/2013 12:00:00 AM	ADDRESS	34.17307	-118.59314	Plan check for energy and emergency lighting. Offices. Northrup Grumman.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60272	17041-30000-41638	601 S FIGUEROA ST #1450	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing office highrise building. Toatl area:2930 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60273	18041-10002-22421	16127 W DEARBORN ST	91343	12	198B141   552	2671020010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM			PC Approved	09/16/2019 12:00:00 AM	ADDRESS	34.23761	-118.48366	CHANGES TO APPROVED SET TO UPDATE WORK DISCRIPTION SYSTEM AC VALUE TO 10KWAC WITH 11.39 KWAC(CEC) AS SHOWN ON THE PLANS AND CUTSHEETS. CHANGES ALSO INCLUDE THE INSTALLATION OF DWP PEODUCTION METER FOR A SYSTEM WITH CEC VALUE GREATER THAN 10KWACPrevious Scope: SUPPLEMENTAL FOR CHANGES TO APPROVED SET - PANEL UPGRADE FROM 200A CENTER FEED TO 225A PV END FEED. CHANGES ARE NOTED UNDER R2PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 11.685KWDC /10.95KWACSCOPE INCLUDES 41 MODULES WITH OPTIMZERS AND CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60274	13041-10000-29274	2049 S CENTURY PARK EAST # 3550	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM			PC Approved	10/21/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN CORRIDOR,SUPPORT AREAS, AND OPEN OFFICESPLAN CHKIS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60275	12041-10000-13081	20842 W HAYNES ST	91306	3	180B109   436	2148024007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.19	-118.58794	Plan check new 7.65KW roof mounted Photovoltaic system for an existing single family dwelling. Permit for  new service panel upgrade and PV sytem.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60276	13041-20000-12712	2121 S SAWTELLE BLVD	90025	11	126B153   971	4260002029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.03889	-118.44213	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60277	16041-10000-36460	2432 S PENMAR AVE 1-4	90291	11	108B149   449	4236004007	RD1.5-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Apartment			11/04/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	33.99404	-118.45027	PC FOR POWER AND ENERGY. (N) 4 UNIT APARTMENT BUILDING OVER GARAGE, NEW SERVICE 600A, 120/208 V, 3 PHASE, 4 WIRE. TOTAL AREA 3261 SQ FT.fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60278	17041-20000-31697	350 S GRAND AVE 3rd Floor	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for power and energy. Project site is the 3rd floor of an existing commercial high-rise building. Project scope is a change of use/tenant improvement. Total lighting area = 20,025 sq. ft.Note: Building application has been generated under 17016-10000-25508	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60279	13041-20001-15016	8445 N RESEDA BLVD	91324	12	192B125   359	2785018060	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.22408	-118.5363	(((changes to approved se of plans. 3 new transformers to supply 208 voltage for dryer units. no change in load. just a change in voltage class and minor load redistribution. reverify effected home runs.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60280	18041-10000-38331	2941 W 70TH ST	90043	8	102B189   584	4008011058	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.97648	-118.3254	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60281	17041-20001-18645	3815 N MARFIELD AVE	91356	3	162B121    90	2177042003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			Reviewed by Supervisor	06/12/2017 12:00:00 AM	ADDRESS	34.13915	-118.55051	expeditepv1install roof mounyed pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60282	15041-20000-24206	8434 N OAKDALE AVE	91306	3	192B113   339	2782007019	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.22304	-118.56653	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (16) modules, and (16) power optimizers. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60283	18041-10000-34503	1726 N VERMONT AVE	90027	4	147B197   146	5590026001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.10248	-118.29159	Plan check for T24 only, Tenant improvement to (E) resturant in URM Building. Total area: 928 sq.ft(B# 18016-10000-27091)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60284	14041-10001-06728	1872 N AVENUE 56	90042	14	159A227   338	5480031045	RE11-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.12863	-118.19635	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60285	17041-20000-05378	6300 W WILSHIRE BLVD Ste 807	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	TI to tenant suite in (E) commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60286	14041-20001-00280	1000 N HIGHLAND AVE	90038	4	144B185   952	5532027014	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.08908	-118.33841	CHANGES TO APPROVED SET OF PLANS. CHANGE NOTED AS DELTA 1 REVISIONS. ADDED 5 NEW CIRCUITS AND KITCHEN EQUIPMENT. CHANGES TO LIGHTING FIXTURES AND REORGANIZED LIGHTING PLAN.  (((ALTERATION OF EXISTING 29000 SQRFT WAREHOUSE. PLAN CHECK FOR POWER AND ENERGY))) CHANGE OF CONTRACTOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60287	14041-20001-15480	9000 N RESEDA BLVD	91324	12	195B125   108	2769001022	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM			PC Approved	11/25/2014 12:00:00 AM	ADDRESS	34.23439	-118.53589	"[[[[[[11/7/14 PLANCHECK FOR POWER ONLY PER INSPECTORS REQUEST. FIRST TIME TENANT. PERMIT AND T24 PLANCHECK UNDER MASTER APP]]]]]]]T24 FOR CHANGE OF USE FROM RETAIL TO PIZZA ""TAKE OUT"" ONLY RESTAURANT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60288	11041-10000-26704	10115 N PINEWOOD AVE	91042	2	204B201   963	2565014***	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			12/14/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.25271	-118.28611	PLAN CHECK FOR REPLACE EXISTING FACP/ANNUNCIATOR. ALL OTHER FIRE ALARM DEVICES ARE EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60289	15041-10000-07192	10926 W OLINDA ST	91352	6	192B173   136	2408013019	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			Reviewed by Supervisor	03/24/2015 12:00:00 AM	ADDRESS	34.22565	-118.36887	PV1 11kw roof-mounted system including (50) Kyocera KU2556 modules  and (2) ABB PVI-6000-OUTD inverters,  and (1) load center interconnecting through the main service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60290	19041-10000-04639	4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	33.99045	-118.44372	CHANGE OF USE RETAIL TO 1,500 sf. RESTAURANT. THE PROJECT SCOPE INCLUDES A NEW RESTAURANT, A STORAGE ROOM, AND UNISEX RESTROOMS.aded load is less than 400 amperesPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60291	18041-20000-28811	1110 S MAGNOLIA AVE	90006	1	130-5A201 283	5076013002	R3-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.05047	-118.28638	Plan check for a fire alarm system for an apartment building. Fire alarm system consists of (1) FACP and (35) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60292	14041-10001-22156	6863 N BABCOCK AVE	91605	2	183B161   771	2324027015	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.19555	-118.40746	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 9.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(37) MODULES: CANADIAN SOLAR CS6P-250PX(2) INVERTERS: SOLAREDGE SE3800A-US-ZB-U & SE5000A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60293	12041-20000-20921	20435 W SORRENTO LANE	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/05/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.27842	-118.57885	New 3 level 45 unit apartment building.  Identified as building B on the plan.  A variance to separate the electrical and fire alarm plan check was submitted on September 5, 2012.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60294	12041-10000-19081	909 E COLON ST	90744	15	036B209   293	7426003001	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	33.79161	-118.25174	in an existing warehouse , upgrade service and installing panelboards, distribution board, and circuits for industrial operationNote : NO CHANGES AT THIS TIME TO THE LIGHTING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60295	15041-20000-08515	20122 W VANOWEN ST	91306	3	180B113    25	2134014024	(T)(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	34.19364	-118.57195	Plan check for Title 24 only. Project scope is a tenant improvement to an existing commercial space. Total lighting area = 620 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60296	15041-10000-42984	5831 N FIGUEROA ST	90042	1	151-5A229  80	5492012025	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.11066	-118.1911	T24 FOR RESTAURANT. REVISING LIGHTING IN THE DINING ROOM. PERMIT HAS BEEN PULLED ON APPLICATION#: 15041-10000-25299	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60297	19041-20000-52434	18040 W SHERMAN WAY	91335	3	183B125   226	2121023042	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	03/02/2020 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.20091	-118.52659	ADD NEW LOADS AND PANELS ON EXISTING 2000 A 480V SERVICE. TOTAL AFFECTED AREA 2,852 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60298	14041-10000-17346	9317 W PICO BLVD bldg C	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05542	-118.3934	Plan check for power and lighting.  Total area = 16,270 sq. ft.Remodel and building addition. Existing services are being replaced.  3 buildings in complex; one is not touched, one is remodeled, one is demolished and rebuilt.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60299	19041-20002-01455	4157 S MARCASEL AVE	90066	11	111B157   683	4233015010	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	33.99967	-118.42206	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO A PREVIOUS REVISION. CHANGING A 100A SUB PANEL TO A 125A SUB PANEL. CLOUDED CHANGE ONLY, ON SINGLE LINE DIAGRAM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60300	16041-10000-00227	12025 W VOSE ST #3	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.3952	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60301	18041-10000-29152	6345 N FALLBROOK AVE	91367	3	180B097   700	2039007900	RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/12/2018 12:00:00 AM	ADDRESS	34.18577	-118.62367	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60302	17041-20000-05499	12500 W ROSCOE BLVD	91352	2	192B165   479	2308005017	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.2214	-118.40551	New 400A 208Y/120V 3ph-4w service for a single story commercial building (7-11). plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60303	12041-10000-01811	5320 S VERMONT AVE	90037	9	108B197   545	5001005014	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	04/16/2012 12:00:00 AM		Issued	04/16/2012 12:00:00 AM	ADDRESS	33.99348	-118.29133	CHANGE OF USE AND T.I. IN EXISTING TWO STORY COMMERCIAL BUILDING FROM RETAIL TO MEDICAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60304	18041-30000-26576	6922 W HOLLYWOOD BLVD 10TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLAN CHECK FOR T24 ONLY, RESTROOM RENOVATION ON THE 10TH FLOOR. APPROX 303 SF TOTAL. PROVIDING NEW LIGHTING AND RECEPTACLES, CIRCUITS ARE FED FROM EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60305	13041-20000-24220	20362 W SCHOENBORN ST	91306	3	192B113   530	2781028035	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.22091	-118.57726	pv1 single family dwelling. total system size 8kw ac using 36 modules. 2 central inverter nonstandard plan.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60306	17041-10000-04554	6433 N PLATT AVE	91307	12	180B093   739	2033010039	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	34.18768	-118.64295	PC for power and energy to existing mcDonalds restaurant. TI Remodel new lighthing and power plance of assembly occupant load more than 100. Total area: 1935 sq ft..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60307	13041-20000-17416	16310 W KALISHER ST PV-1	91344	12	213B137   833	2681007007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.27758	-118.48761	PV-1. Solar edge with power optimizers. One 3.8kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60308	14041-20000-08352	22676 W HAMLIN ST	91307	12	180B097   404	2038023013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.18879	-118.62171	PV1.  Install 5 kW roof-mounted PV system, connect with main service panel.  Transformerless inverter: SE3800A-US-ZB-U with power optimizers.  20 modules: Canadian Solar CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60309	16041-10001-43360	6500 W WILSHIRE BLVD SUITE 700	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			PC Approved	12/21/2016 12:00:00 AM	ADDRESS	34.06371	-118.3703	Plan check Title 24 only in existing high-rise office  building. Total area: 120 sq ft.Note: permit pulled under16041-10001-43360	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60310	17041-20000-29488	1895 N RISING GLEN ROAD	90069	4	150B169  1611	5562019018	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.10513	-118.3852	Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (2) inverters, (60) modules, and (1) load center.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60311	11041-10001-02756	12660 W RIVERSIDE DR # 201	91604	4	168B161   467	2357033017	(Q)C1-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			03/11/2011 12:00:00 AM			PC Approved	03/11/2011 12:00:00 AM	PIN	34.15724389	-118.40930375	T24 plan check only for a revised lighting plan.  The previously approved power and lghitng plan show a room to be demolished which will now remain.  The facility is a medical care facility, and shall comply with applicable section of artical 517.  See original plan 11041-10000-02756.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60312	18041-10000-29298	4701-4703 E YORK BLVD	90042	14	156A223   126	5474016011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	02/24/2023 12:00:00 AM	ADDRESS	34.12274	-118.2128	Plan check for power and energy. Service upgrade in a commercial building. Scope includes new service, and (19) panels. ELECTRICAL PERMIT FOR 4701 UNDER 18041-10000-29292BUILDING PERMIT # 18014-10000-03794 ( 4703 E YORK)BUILDING PERMIT # 18016-10000-21413 ( 4701 E YORK)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60313	14041-20000-28396	13453 N DRONFIELD AVE	91342	7	225B149    76	2504003009	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.31663	-118.44893	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60314	14041-20000-12943	7621 N ASHTON CT	91304	12	186B089    90	2027040007	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	07/19/2014 12:00:00 AM	ADDRESS	34.20946	-118.65	(($0 permit fee due to senate bill 1222 from 2012))) PV1Install roof-mounted solar array on SFD. System size: 9.47kW(1) Power-One PVI-4.2-OUTD-S-US-A transformerless inverter(1) Power-One PVI-6000-OUTD-US-A transformerless inverter(44) ET Solar ET-P660250BB pv modules - arr. in 5 strings	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60315	11041-20000-17733	3651 S CRENSHAW BLVD	90016	10	120B185  1493	5046023001	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2195.00	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM	09/27/2011 12:00:00 AM		Permit Finaled	01/24/2012 12:00:00 AM	ADDRESS	34.02122	-118.33541	PLAN CHECK POWER. NEW 600A SERVICE AND EQUIPMENT. EXISTING RETAIL BUILDING INTO DRY CLEANERS WITH ADDITION. NO CHANGE TO LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60316	16041-20001-10182	14226 W VICTORY BLVD	91401	6	180B153  1097	2240013006	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.18638	-118.4432	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.68 KW , 400 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60317	19041-20000-32647	7200 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	10/06/2022 12:00:00 AM	ADDRESS	34.24842	-118.28878	$0 PERMIT FEE DUE TO SB1222 AND AB1414PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS 304.5KW DC/ 265.22KW AC. SCOPE OF WORK CONSISTS OF (812) PV MODULES WITH OPTIMIZERS, (8) CENTRAL INVERTERS AND A PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60318	15041-10000-19326	4151 W PROSPECT AVE BLD # 25-1ST FL	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	T24 FOR AN OFFICE T.I ( DIGIGTAL MEDIA CENTER). SCOPE INCLUDE NEW LIGHTING, EQUIPMENT, AND RECEPTACLES LOCATED IN BUILDING #25 . TOTAL AREA 1648 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60319	17041-10000-28664	1350 W FLORENCE AVE	90044	8	102B197  1241	6019001012	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	33.97442	-118.29974	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY. TOTAL SQUARE FT 13,950.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60320	15041-10001-11069	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM			PC Approved	05/01/2015 12:00:00 AM	ADDRESS	34.07457	-118.37864	Modifications to approved set.  Changes to Title 24 Part 6 lighting design power calculation.  (((TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 830.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60321	18041-10000-33095	1347 W STORM PKWY	90501	15	045B193   458	7347018035	M2-1VL, M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.81714	-118.30105	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60322	16041-10001-26666	11159 N HERRICK AVE	91331	7	210B161   351	2534026022	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM			PC Approved	10/12/2016 12:00:00 AM	ADDRESS	34.27252	-118.41651	10/12/16Changes to an approved set of plans. Changes include replacing the modules from Jinko Eagle JKM265PP-V with SunEdison SEF270KZD3Y. Note: Permit is paid under PCIS#16041-10000-26666(((((((install new roof top solar pv1 on SFD, 3.8kw AC system. (1) solar edge SE3800A-US  (12) modules,  using power optimizer.*Inspector to verify physical location of the electrical equipments, it shall not obstruct the path of driveway*	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60323	17041-10000-31294	2136 W WASHINGTON BLVD	90018	10	126B193   944	5074033042	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.03974	-118.30707	PC FOR FA IN SINGLE STROY COMMERCIAL BUILDING. TOTAL DEVICE COUNT 55 DEVICES AND 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60324	17041-20000-03236	11239 W VENTURA BLVD	91604	2	162B173   294	2366035036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.14181	-118.37523	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OUTDOOR LIGHTING. 9203 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60325	12041-10000-07403	19718 W REDWING ST	91364	3	174B117   495	2164010023	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2012 12:00:00 AM	04/18/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.17074	-118.56289	PLAN CHECK FOR NEW ROOF MOUNTED 9KW PHOTOVOLTAIC SYSTEM ON A SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60326	19041-10000-05326	10170 N RESEDA BLVD	91324	12	204B125   232	2731018018	P-1VL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.25581	-118.53588	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60327	16041-10010-43714	1030 N SWARTHMORE AVE	90272	11	129B125   840	4423016005	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	DELTA  60 REVISIONS IN BLDGS 2;3;4;5; - SEE ATTACHED LIST OF CHANGES(((((((((PC FOR POWER AND ENERGY.  MIXED USE BUILDING WITH 2 LEVELS  RETAIL CORE AND SHELL, OFFICE CORE AND SHELL, AND RESIDENTIAL OVER 2 LEVELS OF SUBTERRANEAN PARKING.  THE SERVICE SIZE IN FIRST PHASE 5000A, FED THE SECOND PHASE. MAIN SWITCH GEAR 4000A. TOTAL AREA OF LIGHTING 10477 SQ FT. BUI;DING APPLICATION 16010-10000-04147	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60328	17041-10000-08805	1109 N VIRGIL AVE	90029	13	145-5A201 479	5542026037	C2-1D	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.09117	-118.28682	Plan check for Title 24 only in existing space Change of use from manufacture to office space. Total area: 5687 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60329	19041-20000-34208	9543 S COMPTON AVE	90002	15	093A213   172	6048004046	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/23/2021 12:00:00 AM	ADDRESS	33.94954	-118.24646	Fire alarm system for new apartment building. (61) devices with FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60330	18041-10000-10059	19850 W PLUMMER ST	91311	12	198B113   217	2761040029	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.24253	-118.56602	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60331	15041-10000-25414	1050 S GRAND AVE	90015	14	127-5A207 294	5139010013	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.04171	-118.26155	NEW FIRE ALARM SYSTEM FOR A MIX USED APARTMENT AND RETAIL BLDG WITH 22 STORIES AND 311 PARKING SPACES. (925) FIRE ALARM DEVICES(4) FIRE ALARM PANELS(1) CONTROL PANELPER APLICANT ESTIMATION FEE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60332	14041-20002-02337	4640 N LANKERSHIM BLVD GRD FLR-LOBBY	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM			PC Approved	03/05/2014 12:00:00 AM	ADDRESS	34.15499	-118.36841	((changes to approved set of plans. hand writted notes to be printed. per inspector request, plans to reflect as built. new emergency in elevator lobby and dual level switching for corridors. plan check for inpector changes only. all changes clouded delta 1)))****T24 FOR EXISTING OFFICE BUILDING. RECONNECTING TO EXISTING CIRCUITS*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60333	14041-20000-14864	16733 W BOLLINGER DR	90272	11	129B121   868	4415007002	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.04673	-118.5447	PV1Install roof mounted solar system on a SFD. System size: 5kW(1) PVI-5000-OUTD-US-A transformerless inverter(16) SunPower SPR-327E pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60334	16041-20000-26776	1550 N POINSETTIA PL	90046	4	147B181   464	5548010017	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM			PC Info Complete	11/21/2016 12:00:00 AM	ADDRESS	34.09956	-118.34773	"""0$ permit fees due to senate bill 1222""Plan check for a PV2 roof-mounted PV system. System size is 40 kWac and consists of (4) inverters, (176) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60335	14041-20000-33669	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			Verifications in Progress	04/23/2015 12:00:00 AM	ADDRESS	34.09818	-118.32309	PLANCHECK FOR POWER AND ENERGY. [[[[TENANT IMPROVEMENT/CHANGES TO APPROVED]  DUE TO CORE AND SHELL NOT FINALED]] TO RADIO TOWER BUILDING ONLY. T24 ENERGY FEES UNDER:14041-10000-17587CORE AND SHELL APPROVED UNDER BUT NOT FINALED: 13041-10000-11563	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60336	14041-20000-06247	22450 W CALIFA ST	91367	3	174B101    44	2040040007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Expired	05/05/2016 12:00:00 AM	ADDRESS	34.17678	-118.61642	zero dollar permit fee due to senate bill 1222 from 2012PV1 ROOFMOUNTED TRANSFORMERLESS SYSTME. TOTAL SYSTEM SIZE 9.6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60337	10041-20000-22404	19414 W VENTURA BLVD	91356	3	174B117   334	2163002059	C2-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	Public Safety Only			11/08/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.17247	-118.55634	PLAN CHECK FOR FACP REPLACEMENT AND ADDITIONAL DEVICES TO EXISTING FIRE ALARM SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60338	15041-10000-29874	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM			PC Info Complete	09/21/2015 12:00:00 AM	ADDRESS	33.94221	-118.40701	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (DUNKIN DONUTS @ LAX). SCOPE INCLUDES NEW LIGHTING, TWO NEW PANELS, AND ONE NEW METER. TOTAL AREA IS 634 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60339	10041-10000-23826	6420 W WILSHIRE BLVD #1080	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			PC Info Complete	11/30/2010 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I. to existing high rise building of 10th floor.  Install general/emergency lighting.  Plan check for energy only.  Note: Permit is under 10041-20000-23550.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60340	16041-10000-41237	10250 W SANTA MONICA BLVD UNIT 1590	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan check  for first time tenant  (PANINI CAFE, UNIT 1590)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60341	18041-10000-14406	1703 E SANTA ANA BLVD NORTH	90002	15	090A213   129	6065031036	[Q]CR-1VL	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	33.94037	-118.24244	NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 16 PANELS 327W AND A CENTRAL INVERTER 5000W. SYSTEM SIZE IS 5.232KWdc / 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60342	19041-30000-35209	444 S FLOWER ST SUITE 2500	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.05189	-118.25546	ENERGY PC FOR TI OF AN EXISTING 25TH FLOOR OFFICE SPACE IN A HIGHRISE BUILDING. SCOPE OF WORK AREA 5,039SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60343	19041-10000-02872	4525 W WILSHIRE BLVD STE 260	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	ADDRESS	34.06211	-118.32869	Energy plan check for an office T.I located in the commercial building; Scopes inlcudes new lighting and equipment with a total area of 3,000-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60344	17041-10000-07209	9100 S FALMOUTH AVE	90293	11	093B153    17	4118012010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.03	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.95394	-118.43387	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 171475 SQ FT. INDOOR+ OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60345	15041-10000-26202	9168-9174 N DE SOTO AVE	91311	12	198B109   134	2748036017	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.23762	-118.58834	Energy plan check for a change of use from office to office with reseach and test lab, TI. Scope includes new light, equipments and receptacles; Total area is 17672-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60346	15041-10000-28341	912 E 61ST ST	90001	9	105B209   122	6007008004	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	33.98427	-118.25915	New 800A 120/240V 3ph-4w service for (E) 2-story commercial building.   Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60347	18041-10000-21062	8768 N CORBIN AVE	91324	12	195B117   156	2783025095	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Info Complete	08/08/2018 12:00:00 AM	ADDRESS	34.22965	-118.5621	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL.  AMERICAS BEST CONTACTS AND EYEGLASSES. 3251 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60348	18041-10001-37130	7516 S OGELSBY AVE	90045	11	102B165   587	4110009024	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM			Reviewed by Supervisor	10/11/2018 12:00:00 AM	ADDRESS	33.97409	-118.39997	NEW ROOF MOUNTED 10.075 KW PV SYSTEM WITH 13.5KW ENERGY STORAGE ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60349	15041-20000-23537	11478 W MOORPARK ST	91604	2	165B169   292	2365017003	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	PIN	34.15006194	-118.38171208	Plan check for fire alarm system in 8 unit apartment. Total devices 66.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60350	18041-20001-15912	901 N VINE ST	90038	13	144B185  1187	5533018001	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	04/14/2022 12:00:00 AM	ADDRESS	34.0873	-118.3268	SUPPLEMENTAL PLAN CHECK FOR CHANGE OF USE TO APPROVED SET. CLOUDED DELTA B CHANGES ONLY. CHANGES MADE TO ALL PAGES EXCEPT 2.1. ADDITION OF NEW EQUIPMENT, PANEL, AND LOADS. CHANGES MADE TO LOAD CALCULATIONS, PANEL SCHEDULE, FLOOR PLANS, UNIT PLANS, AND T24. T24 LIGHT QUANTITY AND SQUARE FOOTAGE INCREASED BY 17195 SF. MORE LOADS ADDED TO PANEL SCHEDULESCHANGE MADE TO LADWP AVAILABLE FAULT CURRENT LETTER RAISING THE FAULT CURRENT.*ORIGINAL*New 5-story, 70-unit, mixed-use building over 1 level of subterranean parking garage. Work includes a 3000A 208Y/120V service and a total lighting area of 59,422 sq. ft.Note: Building application has been generated under 17010-30000-02328.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60351	17041-20000-19012	817 N VINE ST Bldg A	90038	13	141B185   173	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.0858	-118.32679	Plan check for power and energy. Renovation of existing office building (Bldg A) and addition of 1,500sqft mezzanine. Core and shell. Fed from new 3000A 480V 3ph-4W service. Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60352	15041-10000-15089	2120 E 7TH PL	90021	14	124-5A217 345	5166003006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.0334	-118.22912	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60353	14041-20000-09228	16360 W BRYANT ST	91343	12	195B137   921	2689027032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.22739	-118.48948	PV1.INSTALL ROOF MOUNTED PV SYSTEM SIZE 9KWDC INTERCONNECTED WITH MAIN PANEL(2) TRANSFORMLESS INVERTERS MODEL# SE6000A AND SE 3000A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60354	19041-10000-09417	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC t-24 only, for terminal 3 in LAX for restrooms and office rooms. scope area 2280 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60355	13041-10002-27145	804 N EL CENTRO AVE	90038	13	141B189   100	5534031017	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM			PC Approved	07/16/2018 12:00:00 AM	ADDRESS	34.08554	-118.32428	PC FOR CHANGES TO APPROVED SET OF PLANS. SERVICE DROPPED TO 600A AND REMOVED TRANSFORMER. UPDATED LIGHTING AND T24 AS WELL AS POWER CIRCUIT WIRING. ALL CHANGED CLOUDED DELTA 2.NOTE PERMIT IS PAID UNDER PCIS#13041-10000-27146	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60356	18041-10001-08258	21901 W SHERMAN WAY	91303	3	183B101    49	2111022012	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.20125	-118.60466	Alterations to a Chase bank- replacing existing lights with LED type using existing branch circuitstotal affected area 20012 sq.ft. PLAN CHECK IS FOR TITLE 24 ONLY. EMERGENCY LIGHT ARE EXISTING TO REMAIN. PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER 18041-10000-08258.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60357	14041-20000-02446	20000 S WESTERN AVE	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	12/26/2014 12:00:00 AM	ADDRESS	33.85008	-118.30908	PV2 PHOTOVOLTAIC SYSTEM. TOTAL SYSTEM SIZE 930KWAC WITH ISOLATION TRANSFORMER. ***ZERO FEES DUE TO 2012 SENATE BILL 1222.***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60358	12041-10000-28664	13225 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.31109	-118.42901	Plan check for T24 and Emergency Lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60359	18041-20000-05766	6757 W HOLLYWOOD BLVD	90028	13	148-5A185  92	5547011016	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Issued	05/18/2018 12:00:00 AM	ADDRESS	34.10172	-118.33778	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,095 sq. ft.Note: Building application has been generated under 16016-30000/30001/30002/30003/30004-03931	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60360	12041-20000-12515	6308 S 10TH AVE 1-12	90043	8	105B185   880	4006012008	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.00	Electrical	Electrical	Apartment			05/31/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	33.98255	-118.32777	remodel 13 units apartments	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60361	19041-20000-06628	11589 W TUXFORD ST 2	91352	6	192B169   223	2632015030	CM-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.22532	-118.38425	T24 PLAN CHECK FOR EXISTING COMMERCIAL BUILDING UNIT 2, TOTAL SQUARE FOOTAGE = 96 SF LIGHTING AND OUTLETS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60362	17041-20000-46647	16241 W MIDWOOD DR	91344	12	216B137   277	2605010030	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Issued	01/16/2018 12:00:00 AM	ADDRESS	34.2879	-118.48637	Plan check for AC coupled battery backup system for SFD.(2) 5kW Tesla Powerwall 2.  Existing solar pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60363	15041-20002-29365	5625 W IMPERIAL HWY 2ND FLR	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	33.93197	-118.382	CHANGES TO LIGHITNG TYPE. CHANGES CLOUDED DELTA 1 REVISIONS. USING RETROFIT KITS WITH DIMMABLE BULBS. RELISTING OF FIXTURES OK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60364	13041-10000-19777	309 S BERENDO ST #1-8	90020	10	135B197   206	5502006020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			07/25/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.06874	-118.29442	PC FOR ENERGY ONLY. LOW RISE RESIDENTIAL WITH 8+ PKG SPACESDIVIDE (4) EXISTING APT UNITS INTO (8) UNITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60365	17041-10000-21795	15607 W ROSCOE BLVD	91343	6	192B141   431	2654029022	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.22156	-118.47246	TItle 24 plan check.  Replace existing fixtures with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60366	19041-20001-02552	13171 N TELFAIR AVE B	91342	7	225B141  1501	2604002052	M1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			PC Approved	08/16/2019 12:00:00 AM	ADDRESS	34.31032	-118.47927	08-16-2019 Changes to an approved set of plan, Change include remove controlled receptacles. All Changes has been clouded as delta 3. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60367	16041-20001-26546	8156 N SYLMAR AVE	91402	6	192B149   556	2212006010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.21935	-118.44649	[[ 1/8/17  CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. CHANGING INVERTER SYSTEM TO SUNVERGE SIS 6848 ]]]Plan check for PV roof mounted battery backup system. System size: 2.5kW with 12 modules and 12 microinverters and 180Ah battery backup.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60368	17041-20001-14635	11600 N ANDASOL AVE	91344	12	213B129   154	2607008024	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM			PC Approved	05/10/2017 12:00:00 AM	ADDRESS	34.28148	-118.51251	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system to an existing PV system. System size addition is 3 kWac and consists of (1) inverter and (9) modules. Total system size is 10.6 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60369	19041-10001-51763	10200 N RATHBURN AVE	91325	12	204B125   225	2731018026	R1-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM			Reviewed by Supervisor	12/26/2019 12:00:00 AM	ADDRESS	34.25625	-118.53255	Expedite feesplan check for PV-1 system. system includes tile pv solar system (192) , (2) inverters and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60370	11041-20000-25741	2216 W FARGO ST	90039	13	145-5A209 306	5422017037	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM			PC Approved	02/17/2012 12:00:00 AM	ADDRESS	34.09206	-118.25934	Iglesia Bautista Spanish CongregationEnergyCOMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 8/24/11. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60371	14041-20000-00650	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	33.87528	-118.29083	NEW 2000A DISTRIBUTION EQUIPMENT FEEDING (2) 1200A DISTRIBUTION BOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60372	15041-10001-26965	19600 S VERMONT AVE	90502	15	057B197    31	7351033009	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	33.85227	-118.2903	CHANGES TO APPROVED SET OF PLANS. ADDITIONS OF OFFICE PARTITIONS TO PLANS AND NEW CIRCUITS. ADDITION OF AC UNIT. CHANGE TO LIGHITNG. RECHECKING POWER AND LIGHTING ALL CHANGES NOTED DELTA B ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60373	17041-10001-43314	682 W 9TH ST	90731	15	015B197   799	7454005049	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	33.73624	-118.29185	Plan check for fire alarm system 14 fire alarm devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60374	16041-20000-27077	12670 W SEACOAST PL	90094	11	102B161  1279	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.97615	-118.41362	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.1.5kW ungrounded system. (6) 250W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60375	16041-20000-05659	412 E 42ND PL	90011	9	114A205   227	5113010021	R2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.00642	-118.26798	Plan check for PV roof mounted system. System size: 5.0kW with 14 modules and 1 inverter(5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60376	11041-20000-18003	6100 N TOPANGA CANYON BLVD #2120	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM	08/24/2011 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.18131	-118.60555	Plan check T24 Energy for Interior tenant improvements. Relocate and remove existing fixtures for compliance of  T24 calculation. Existing exit and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60377	12041-20001-00200	8024 W MELROSE AVE	90048	5	141B177   618	5527015037	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM			PC Approved	02/27/2012 12:00:00 AM	PIN	34.08349782	-118.36462438	Changes from previously approved plans.  Changes include the as-built and relocated switches.  Plan check for energy only.  Note: Permit issued under 12041-20000-00200.*****Plan check for energy only.  Permit is for relocation of existing panel and installing new circuits to sale area counter and lighting. *****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60378	10041-20000-05502	670 S BIXEL ST	90017	1	130-5A207 175	5143028022	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.05156	-118.26356	CHANGE OF USE  RETAIL TO DRY CLEANING AND LAUNDRIES (PICK-UP AND DELIVERY STATIONS AND SELF-SERVICE). NO CHANGE IN PARKING.  Connecting to existing 1600 amp buss service of 200 amp panel  as indicated on previously approved plan showing as future work. This plan check is power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60379	11041-20000-17175	8360 N SUNLAND BLVD	91352	6	192B177   425	2408014024	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM			PC Approved	08/15/2011 12:00:00 AM	ADDRESS	34.22278	-118.36577	PLAN CHECK T24 ENERGY FOR NEW ADDITIONS AND TI FOR 24HRS GAS STATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60380	19041-10001-16711	4326 S STEWART AVE	90066	11	108B157   455	4231014005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM			PC Approved	05/23/2019 12:00:00 AM	ADDRESS	33.99386	-118.42741	Expedite per applicant request.(((Plan check for a PV1 7.6KW AC / 4.7KW DC roofmounted system with (1) inveter, (1) transformer, (1) subpanel, (1) battery system, (13) modules and optimizers interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60381	15041-10000-24619	6000 W PICO BLVD	90035	10	129B173   338	5068011006	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.05223	-118.3713	PC FOR ENERGY ONLY, T-24 TO AN (E) BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING INDOOR/OUTDOOR AND POWER. CONNECTED LOAD <400AMPS. TOTAL SQ. FT. 4887.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60382	18041-10000-38221	2051 W 77TH ST	90047	8	099B189   175	6017019013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	33.97009	-118.31513	NEW ROOF MOUNTED 4.42KW (DC) PV SYSTEM WITH 15 PV PANELS ON A SINGLE FAMILY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60383	12041-10000-27618	11600 N INDIAN HILLS ROAD 1ST FL-2ND FL	91345	7	213B149   150	2664023028	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1066.06	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.2811	-118.4587	INTERIOR NON STRUCTURAL TENANT IMPROVEMENT TO PORTION OF 1ST. & 2ND FLOOR OF (E) MEDICAL BUILDING (REMOVE AND REPBUILD NON BEARING PARTITION WALLS WITH NEW SUSPENDED CEILING . PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60384	19041-20000-29759	504 S BONNIE BRAE ST	90057	1	133-5A205 279	5154025008	R4-1	Central	Westlake	Westlake South		2089.04	Electrical	Electrical	Apartment			08/16/2019 12:00:00 AM	08/27/2020 12:00:00 AM		Permit Finaled	11/03/2023 12:00:00 AM	ADDRESS	34.05915	-118.27178	POWER PLAN CHECK FOR REPLACING 600A 3P 4W MDP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60385	10041-10000-22596	108 W 9TH ST	90015	14	127-5A209 274	5139002021	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.04173	-118.25548	CHANGE OF USE FROM RETAIL TO BAR & LOUNGE ON GROUND (FIRST STORY) LEVEL. EPC IS FOR  POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60386	14041-10000-03631	9007 N WOODMAN AVE	91402	6	195B153   291	2639033006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	PIN	34.23281976	-118.43942219	PC FOR POWER AND ENERGY FOR NEW 1 STORY BLDG.  Vanilla shell per applicant. No common area between new building and adjacent building.  Fees to be added for OLTG when they submit it. design-build12010-20000-02767 description: NEW 1-STORY TYPE V-B RETAIL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60387	10041-20000-05343	6700 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.19196	-118.6056	TENANT IMPROVEMENT MARKET AREA EXPANSION. NEW WALKIN COOLER/FREEZER, SALES FLOOR LIGHTING MODIFICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60388	14041-10001-03384	6600 N TOPANGA CANYON BLVD Suite 1078	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	(((5/8/2014- Changes made to approved set. Removed and relocated some lights)))TI FOR INTERIOR OF EXISTING RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60389	17041-10000-28780	4214 S SUTRO AVE	90008	10	114B189  1238	5023027011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.00666	-118.32292	PV SYSTEM WITH BATERY STORAGE. USING 12 PV MODULES WITH 3KW INVERTER. BATTERY UNIT RATED 5.8K. PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60390	13041-10000-29853	5326 E TEMPLETON ST	90032	14	142-5A237 193	5219015006	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.0848	-118.16778	PV1, ROOF-MOUNTED SOLAR INSTALLATION TO INTERCONNECT WITH EXISTING 200A MAIN. SYSTEM SIZE IS 9.84KW DC WITH 41 MODULES (CANADIAN SOLAR CS6P-240P) AND 2 POWER ONE PVI 5000-OUTD-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60391	17041-20000-01332	931 N LINDA FLORA DR	90049	5	141B145    99	4368024010	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM			PC Info Complete	08/01/2017 12:00:00 AM	ADDRESS	34.0849	-118.46587	Plan check new SFD 600 amp.  plan check for power only. Note: Single Family Dwelling permit is under Building application number  15010-20000-02582	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60392	17041-10001-43816	11356 W DONA LOLA DR	91604	2	159B173   400	2380017022	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.13224	-118.37858	VOID ( DUPLICATE APPLICATION)NEW ROOFTOP SOLAR SYSTEM CONSIST OF 52 MODULES (SILFAB SLG-M 370 WATT) AND 52 MICROINVERTERS (ENPHASE IQ6PLUS-72-2-US).  SYSTEM SIZE IS 19.24KWdc and 15.08KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60393	10041-20000-24337	512 E ROSE AVE	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			12/07/2010 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	03/28/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	New Mix-Used building with 3 stories and 2 parking stories above grade level.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60394	12041-10000-16512	11200 N CHIMINEAS AVE	91326	12	210B125   161	2715031021	RE11-1	North Valley	Northridge	Northridge East		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.27425	-118.52847	New roof mounted 5.88KW Photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60395	17041-10000-14404	4551 S GLENCOE AVE STE 300	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Issued	05/02/2017 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC for energy only, Indoor Title-24. TI romodel of existing office building. Adding new lighting and power. Area: 6154 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60396	18041-10000-06983	900 W WILSHIRE BLVD 12TH FLR.	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.05001	-118.25963	T-24, PC FOR ENERGY ONLY. NEW PUBLIC CORRIDOR AND AT ELEVATOR LOBBY. SCOPE INCLUDES NEW LIGHTS FOR A CORRIDOR SPACE. TOTAL AFFECTED AREA IS 1435 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60397	18041-10000-34846	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	05/17/2020 12:00:00 AM	ADDRESS	34.05886	-118.41642	FULL PLAN CHECK  FOR INSTALLATION OF A NEW CHILLER PLANT FOR THE HVAC SYSTEM OF AN EXISTING 39 STORY OFFICE BUILDING; SCOPE INLCUDES: (1) NEW 400A DIST. BOARD, (1) 1000A DIST. BOARD, (1) 1200A DIST.BOARD (1) 100A SUBPANEL, NEW NORMAL/EMERGENCY LIGHTING AND RECEPTACLE IN THE AREA COVERS WITHIN THIS SOW. TOTAL AREA: 9,623 SQ.FT, (B# 18016-10000-29401)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60398	12041-10000-13087	19244 W MALDEN ST	91324	12	192B117   212	2784006048	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.22542	-118.55285	Plan check for new 10.455KW roof mounted Photovoltaic system using transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60399	14041-10000-32745	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.04338	-118.26581	Title 24 plan check only.  Total area = 6,779 sq. ft.T.I. to existing commercial space.  Change of use from a restaraunt to a retail space in Staples Center. Tailored method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60400	11041-10001-01604	7512 N VINELAND AVE 1-23	91352	2	186B173   448	2410001030	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM			PC Approved	02/25/2011 12:00:00 AM	ADDRESS	34.20707	-118.37012	Change the service entrance conductor. EPC is for the change. (((((((((((((New 600 Amp service and 23 meter for an appartment building. EPC is for power.)))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60401	16041-20001-02257	7926 N CHASTAIN AVE	91335	12	189B129   682	2101029005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.21437	-118.52351	Expedite per customer request.PV1. Plan check for the addition of a 3 kW AC PV system onto an existing 6.9 kW PV system. For a total system size of 9.9 kW. New PV system consists of(10) Kyocera KU265 Modules(1) ABB PVI 3.0 Inverter(1) Bryant 125A Load Center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60402	18041-20000-04540	845 S LINCOLN BLVD	90291	11	111B145  1050	4239014028	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	33.99859	-118.46258	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60403	13041-10000-23224	18010 W CHATSWORTH ST	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.26474	-118.52445	permit to be pulled at EPC counter only.PC FOR ENERGY ONLY. TI FOR (E) RALPHS (addition of track lighting and fluorescents). >30,000SF.  Starbucks Kiosk under separate health and building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60404	15041-10000-03004	3650 W MARTIN LUTHER KING, JR BLVD SPACE 220	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.01118	-118.33649	Title 24 plan check only.  Total area = 1,549 sq. ft.Installation of new fixtures and cashwrap in existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60405	19041-10000-51388	1525 W SEPULVEDA BLVD	90501	15	045B193   511	7347017070	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM	ADDRESS	33.81565	-118.30466	PLAN CHECK FOR TITLE 24. SCOPE OF WORK INCLUDES ALTERATIONS TO LIGHTING FIXTURES. ALL CIRCUITS ARE EXISTING TO REMAIN.  TOTAL AFFECTED AREA: 4374 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60406	12041-10001-26458	815 N LA CIENEGA BLVD	90069	5	141B173   154	4337002039	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/17/2013 12:00:00 AM	ADDRESS	34.08582	-118.37662	Revision to approved plans. Lighting and T24 calculation. Permit under original application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60407	16041-10002-02487	3900 W 6TH ST	90005	10	135B193   885	5503030001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM			PC Approved	10/05/2019 12:00:00 AM	PIN	34.06325314	-118.30807759	Change to an approved set by remodeling lighting plan, power plan and service load calculation. All changes under delta-3 only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60408	09041-10001-24186	3435 W WILSHIRE BLVD #108	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM			PC Approved	01/11/2010 12:00:00 AM	ADDRESS	34.06194	-118.29866	New and relocated lighting for remodeled restaurant in high building. Inspector requested T24 energy plan check only.  Emergency lighting requirements were not determined.  But emergency circuit to exit signs is provided. Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60409	14041-10000-15571	706 E DUCOMMUN ST	90012	14	130-5A217 264	5173016005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.05183	-118.23298	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH  NEW FLUORESCENT LIGHT FIXTURES. TOTAL AREA 20400 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60410	13041-10001-26320	8386 N SAUSALITO AVE	91304	12	192B101   437	2004009017	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.22225	-118.61567	][][]EXPEDITED PER APPLICANT REQUEST][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A NON STANDARD PLAN WITH POWER OPTIMIZERS(OP250-LV).; SYSTEM SIZE IS 7KW DC WITH (28) MODULES: HANWHA #HSL60P6-PB-4-250QW(1) SOLAREDGE #SE6000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60411	16041-20000-08866	6320 W 85TH ST	90045	11	096B165   394	4108020018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	33.96103	-118.39729	PV2.  Install 22.3 kW DC roof-mounted PV system.  (3) 6 kW inverters with (72) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60412	18041-10000-33441	608 S IMPERIAL ST	90021	14	126A217   198	5164014014	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.03768	-118.23142	Tenant Improvement to existing Take out restaurant, relocate cafe area and convert it to bakery.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60413	12041-20000-09907	5060 W RODEO ROAD Fallas	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.02015	-118.35387	Fallas store. Plan check for energy only. Outdoor lighting. 336 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60414	15041-10001-25396	342 E 61ST ST	90003	9	105B205   628	6006024006	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	33.98415	-118.2681	EXPEDITED RSES PLAN CHECK PER APPLICANRT REQUEST.<<PV1, INSTALL 2.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE.(8) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60415	15041-20002-09444	11146 W VANOWEN ST	91606	2	180B173    35	2319013014	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	PIN	34.19358386	-118.37399427	08-21-2015 Change to approved set of plan. Changees include modules layout on roof and branch circuit breaker size to 20A. [[[[[[PV1 SFD. TOTAL SYSTEM SIZE 3.5KW AC USING SINGLE TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 14 MODULES.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60416	15041-10000-20206	2238 E 1ST ST	90033	14	127-5A223 143	5183009013	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Issued	07/29/2015 12:00:00 AM	ADDRESS	34.04419	-118.2113	PC FOR ENERGY. TI. RETAIL STORE. NO CHANGE OF USE.  ADDING LIGHTING AND NEW 200 A PANEL.TOTAL AREA 1574 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60417	19041-10000-28015	6725 W SUNSET BLVD	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.09814	-118.33717	Energy PC only for Ground floor of an office building. area of scope 1185SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60418	10041-20000-12475	400 S HOPE ST 17th fl	90071	9	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.05199	-118.25366	energy plan check 17th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60419	17041-20000-13960	7283 N CIRRUS WAY	91307	12	186B093   656	2027010024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.20247	-118.63703	Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with a 150A MSP.Derating main breaker to 125A. 7.04kW ungrounded system. (22) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60420	19041-20000-52879	777 N VIRGIL AVE	90029	13	141B197   209	5539017001	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.08551	-118.28701	Plan check for Title 24 Energy only, new lighting. Total area: 641 sq ft. B#19016-20000-34754	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60421	18041-10000-06110	20553 W SHERMAN WAY	91306	3	183B109   924	2113022023	RA-1, RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.20127	-118.58122	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60422	19041-10000-16985	21045 W OSBORNE ST	91304	3	195B105    41	2779048009	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	06/10/2019 12:00:00 AM	ADDRESS	34.23322	-118.59228	PV2. SYSTEM SIZE OF 200KWDC AND 182KWAC WITH (513) MODULE ROOFMOUNTED AND OPTIMIZERS. SCOPE OF WORK INCLUDES (2) INVERTERS SE99.9K-US AND 66.6 SEK-US. SERVICE AND DISTRIBUTION ON EXPRESS PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60423	15041-10001-21133	1307 W SEPULVEDA BLVD #3	90501	15	042B197   227	7347018089	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	33.8138	-118.2996	02/09/2016CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES ON DELTA 10. CHANGES INCLUDE THE CHANGE OF CIRCUIT FOR THE DRIVE THRU SIGNAGE. Full plan check for first time tenant  ( The coffe bean & Tea leaf) owner build out. Main Scope includes (2) panels connecting to an existing 600-Amp service, toal (52) circuits, (2) equipment and 1651-SQ feet for T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60424	16041-30002-22691	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	33.94248	-118.40461	02-15-2018 Changes to an approved set of plan LAX Project 5 Terminal 5. Changes include addition of 3 transformers and 3 panels and modify circuits in existing panels. Changes apply to deltaRFI#1077	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60425	17041-20000-40409	550 S HOPE ST ste 1950	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.04989	-118.25574	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60426	16041-10001-28830	21801 W OXNARD ST	91367	3	177B105    56	2146005179	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.17941	-118.60306	02/16/2017 Changes to an approved set of plans. Changes include replace lighting fixtures. Changes has been clouded as delta 5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60427	15041-20001-14538	4124 N STANSBURY AVE	91423	4	165B153   976	2266026010	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2015 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	34.14515	-118.44095	Expedited per customer request.PV1. Install roof mounted PV system sized 24.7 kW. Interconnected with main service panel.  q  (115) Yingli YL250-P Modules(115) Enphase M215 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60428	14041-20000-19547	20028 W HEMMINGWAY ST	91306	3	189B113   774	2106022051	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Expired	08/23/2016 12:00:00 AM	ADDRESS	34.21389	-118.56972	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60429	17041-20001-19507	9951 N MEMORY PARK AVE	91345	7	201B145    36	2660011031	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM			PC Approved	06/26/2017 12:00:00 AM	ADDRESS	34.25154	-118.46425	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (38) modules, (19) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60430	16041-20001-43300	23033 W OXNARD ST	91367	3	177B097   492	2039008027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.17934	-118.62858	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.4KW. CENTRAL INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60431	17041-10000-16236	8181 N SUNLAND BLVD	91352	6	192B173   817	2409001015	[Q]C2-1L-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.2189	-118.36943	T.I. TO (E) RETAIL BUILDING TO COMBINE SUITES INTO (N) CONVENIENCE STORE (2,340 SF TOTAL).  NO CHANGE OF USE OR PARKING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60432	11041-20000-19472	1515 N VERMONT AVE	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01, 1913.00	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM	12/01/2011 12:00:00 AM		Permit Finaled	02/22/2012 12:00:00 AM	ADDRESS	34.09867	-118.29207	replace 2000a swichgear in medical office building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60433	14041-20000-33285	420 E 3RD ST	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM			Corrections Issued	12/09/2014 12:00:00 AM	ADDRESS	34.04686	-118.24182	Plan check for power only. Install new 1400A switchgear equipment, tapped off of an existing 4000A pull section/service. Install/feed two empty panels from new section.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60434	18041-10000-01951	1901 S AVENUE OF THE STARS # 1901	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.05949	-118.41705	TENANT IMPROVEMENT IN OFFICES;NEW LUMINAIRES AND CIRCUITSPLAB CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60435	14041-10000-23842	620 S UNION AVE	90017	1	132A205   143	5142028031	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.05638	-118.26929	TI for methane detector system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60436	14041-10000-34276	3866-3868 W 6TH ST	90005	10	135B193   884	5503029021	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	PIN	34.0633409	-118.30746395	CHANGE OF USE AND COMBINE TWO RETAIL TENANT SPACES TO RESTAURANT WITH MEZZANINE IN URM BLDG.PLAN CHK IS FOR TITLE 24 COMPLIANCE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60437	19041-30000-00252	12751 W MILLENNIUM	90094	11	102B161  1175	4211033020		West Los Angeles				2756.02	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Issued	09/18/2019 12:00:00 AM	ADDRESS	33.9761	-118.41651	Plan check for power and energy. Project site is (5) retail tenant spaces of an existing commercial building. Project scope is tenant improvements and common areas and restrooms. Total lighting area = 12,536 sq. ft.Note: Building application has been generated under 18016-30000-41269	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60438	14041-10000-22274	400 W WORLD WAY TERM 4B	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	TERMINAL 4B - GOURMET FOOD TRUCK AREA PLAN CHK IS FOR TITLE 24 ONLY-REFERENCE 12041-10001-15263	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60439	14041-20000-12174	1800 S ROBERTSON BLVD	90035	10	129B169  1331	4303006001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM			Corrections Issued	05/21/2014 12:00:00 AM	ADDRESS	34.04653	-118.38597	TI for veterinary clinic occupying single-story (from grade facing Robertson) building.  Plan check for Title 24 due to changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60440	16041-20000-00883	10126 N COLUMBUS AVE	91345	7	204B145   655	2660013032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.25447	-118.46478	PV1.  Install 5 kW roof-mounted utility-interactive PV system.  (19) Kyocera KU2656ZPA modules with ABB PVI-5000-OUTD-US.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60441	18041-10000-28563	1035 N SERRANO AVE 1-5	90029	13	144B193   915	5536025023	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Apartment			07/30/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	11/14/2023 12:00:00 AM	ADDRESS	34.0895	-118.30665	FULL PLAN CHECK FOR A NEW 5 UNIT APARTMENT BUILDING WITH A ROOF DECK. 600 A, 120/240V, 1PH. SERVICE. TOTAL AREA: 4,468 SQ.FT (OUTDOOR)B#17010-10000-01523	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60442	15041-30000-42264	18549 W STRATHERN ST	91335	12	189B125   270	2103009029	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.21577	-118.53781	Addition of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60443	17041-20000-08813	15303 W VENTURA BLVD Suite 1450	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,933 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60444	15041-10000-37180	230 E 107TH ST	90003	8	090A205   327	6063031008	R2-1	South Los Angeles	Wilmington - Harbor City	Wilmington		2411.10	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	33.93911	-118.27064	PV1 INSTALL 7.42 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (28) MODULES: KYOCERA KU2656ZPA(2) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60445	13041-20000-33352	1035 E 27TH ST	90011	9	118-5A209 232	5128024037	[Q]C2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.01801	-118.25565	PC FOR T24 ENERGY ONLY. PER APPLICANT REQUEST. WORK DONE IN COMMUNITY ROOM. NEW LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60446	09041-10001-19841	4103 W OLYMPIC BLVD	90019	4	132B189  1121	5092003011	C2-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM			PC Approved	03/01/2010 12:00:00 AM	ADDRESS	34.0545	-118.32198	PLAN CHECK ONLY. REVISION TO APPROVED PLANS. CHANGES TO OUTDOOR LIGHTING T-24 ENERGY CALCULATION. NO CHANGES TO LOAD FROM PREVIOUS APPROVED PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60447	16041-10000-17841	11835 W OLYMPIC BLVD 1150E-1160E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.03301	-118.45119	T-24, TI TO AN EXISTING OFFICE SPACE IN A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3412.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60448	13041-20000-19932	1161 S WESTWOOD BLVD	90024	5	132B153   323	4363023034	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.05927	-118.4447	renovation to starbuck coffee place	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60449	15041-30000-37304	3516 S SAWTELLE BLVD	90066	11	117B157   438	4249032045	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.0163	-118.42336	Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 38.5 kWac.  System consists of 5 7.7 kWac inverter with 27 modules each.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60450	12041-10000-14770	3658 W 3RD ST	90020	10	135B197   188	5502005053	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			Corrections Issued	10/02/2012 12:00:00 AM	ADDRESS	34.06889	-118.2959	Plan check for power and energy. Ti. Change of use from retail to laundromat.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60451	15041-10000-05231	7109 W SUNSET BLVD	90046	4	147B181   588	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.09814	-118.34469	FIRST INTERIOR TENANT IMPROVEMENT FOR WABA GRILL RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60452	12041-10000-12422	7511 S AGNEW AVE	90045	11	102B161   208	4110025053	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	ADDRESS	33.97242	-118.40943	Plan check installation for roof mounted 4.56KW photovoltaic system (SolarEdge transformerless inverter) using DC-DC powerbox. Modules on main house amd detached garage. Site is located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60453	15041-10000-11684	910 S 5TH AVE	90019	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.05552	-118.31845	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 6 KW.  CENTRAL INVERTER STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60454	18041-10000-41001	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO-POD, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	34.12774	-118.26247	PLAN CHECK FOR T24 ONLY, TI OF SHOP-IN COOLER, DELI AND ROTISSERIE AREAS. TOTAL AREA UNDER THE SCOPE: 348 SQ.FT.(B# 18016-10000-34596)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60455	19041-10000-03384	8533 W HARGIS ST	90034	10	123B169   717	5065007029	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.03329	-118.37956	Plan check for a 5.2KW AC roofmounted system with (14) modules and (1) inverter interconnecting through the service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60456	14041-10000-32694	21541 W NORDHOFF ST STE C	91311	12	198B105   108	2746011***	[Q]MR2-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.23562	-118.60009	PLANCHECK FOR ENERGY ONLY. TOTAL AREA 3002 SQ FT. STTLE'S PLUMBING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60457	17041-10000-14381	5161 E HUNTINGTON DR NORTH	90032	14	144A235    69	5309001901	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.09006	-118.16866	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new LEd ones. Area: 14,380.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60458	13041-10000-33039	13131 N MESA VERDE WAY	91342	7	225B165		R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.31142	-118.40683	PV1, Install 6.5 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (26) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60459	14041-10000-24597	4640 N LANKERSHIM BLVD 100	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.15499	-118.36841	Title 24 plan check on a T.I office suit 100 insde commercial building. Note, plan check based on 2008 standard due to building application is submited before July 1st.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60460	16041-10000-23512	1345 N FIGUEROA PL	90744	15	033B201    19	7412009010	[Q]R3-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Harbor City		2943.02	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	PIN	33.78947513	-118.2836223	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 40.25KWac. FOR BLDG 3 & 4 (ADDRESS 1345 FIGUEROA PL) (176)MODULES, (7)INVERTER-, (1)200A PANEL. PERMIT FEES ARE $0 DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60461	11041-10000-08475	515 S FIGUEROA ST 19th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			Plans on Hold	10/18/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60462	14041-10000-16496	2029 S CENTURY PARK EAST C-LEVEL	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR AN ELECTRICAL ROOM. D LEVEL.  NEWLY CONNECTED LOAD < 400A.  350 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60463	13041-20000-09112	15821 W VENTURA BLVD	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/12/2013 12:00:00 AM	ADDRESS	34.15584	-118.47812	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60464	17041-10000-28208	22944 W COLLINS ST	91367	3	174B097   389	2041014031	RE9-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.17348	-118.62707	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS           14.4KWac.(45)AC MODULES- SPR-X22-360-C-ACNote: Fee $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60465	17041-10000-19824	6730 N SUNNY BRAE AVE	91306	3	180B109   109	2148001006	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM			Reviewed by Supervisor	07/26/2017 12:00:00 AM	ADDRESS	34.19293	-118.5806	plan check for battery back-up system(tesla power wall 2) on single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60466	19041-20000-29411	5820 W LA MIRADA AVE	90038	13	144B189   222	5534019029	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	05/15/2021 12:00:00 AM	ADDRESS	34.09365	-118.31653	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW 4-STORY 17-UNIT APARTMENT BUILDING. SCOPE OF WORK CONSISTS OF 1 FA PANEL, AND 100 FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60467	11041-20000-02237	3250 W WILSHIRE BLVD #400	90010	10	132B197    43	5094008027	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.06162	-118.29337	T.I. to a high rise building partial of 4th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60468	19041-20000-08611	10801 N BALBOA BLVD	91344	12	207B133   284	2696019014	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.26622	-118.5025	PV1.  Install 5.8 kW DC / 5 kW AC roof mounted grid tied PV system.  (20) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60469	16041-10000-24819	9919 N TELFAIR AVE	91331	7	201B161   270	2624007025	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.25003	-118.41146	PV1, rooftop solar installation 3.8 KW AC system.   (17) modules,  (1) inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60470	17041-10000-13481	6600 N TOPANGA CANYON BLVD #2022	91303	3	180B101   822	2139004044	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Info Complete	06/08/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC for energy only, Indoor title24. Interior TI to existing retail space inside of existing mall. New lighting and power. Area: 742 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60471	15041-10000-01959	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.07196	-118.24719	Pc for t24 only. Renowation to dodger stadium. Total area 7200 sq ft. VISITING TEAM CLUBHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60472	15041-30000-39263	7868 N OSO AVE	91306	3	189B113   796	2107011069	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.21367	-118.57525	Installation of new roof mounted solar PV array on single family dwelling.  Total system size = 8.2 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60473	10041-10000-15686	873 N SWARTHMORE AVE	90272	11	129B125   648	4412003006	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	02/03/2011 12:00:00 AM	ADDRESS	34.0468	-118.52611	CHANGE OF USE - FROM RETAIL  TO YOGURT SHOP ( NO SEATING) TENANT IMPROVEMENTS FOR  770 SF  YOGURT SHOP PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60474	13041-10000-21884	7741 N HAYVENHURST AVE	91406	6	189B137   121	2205009090	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			PC Approved	08/14/2013 12:00:00 AM	ADDRESS	34.21152	-118.49265	permit to be pulled at EPC counter only.  PC for energy only. Plan check request by inspector. TI TO (E) WAREHOUSE-SKYZONE.REPLACE MH IN WAREHOUSE. adding Emergency LTG in CORRIDORs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60475	10041-20000-03478	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	C2-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	02/26/2010 12:00:00 AM		Permit Finaled	03/10/2010 12:00:00 AM	ADDRESS	34.04338	-118.26581	PROVIDE AND INSTALL NEW WIRING FOR DISPLAY AND LIGHTING. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY. VERIZON WIRELESS STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60476	15041-20002-40197	6316 N TOPANGA CANYON BLVD Building C	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	34.18578	-118.60514	[5/4/16 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGE OF MODULE TYPE TO JA SOLAR JAP6-72-350. CHANGES TO ROOF LAYOUT, REMOVED ONE INVERTER AND DOWNGRADED THE SOLAR SUBPANEL FROM 200 AMPS TO 100 AMPS ]]]0$ permit fees due to senate bill 1222.Plan check for a PV2 roof-mounted PV system. System size 84 kWac and consists of (3) inverters, (1) load center, and (285) modules. This PV system is part of a larger 672 kWac PV system, which is located on top of (3) separate structures: Building B, Building C, and the Parking Structure. (3) applications will be generated under (1) PCAM number.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60477	19041-30000-16365	1031 S BROADWAY 3rd Floor	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.04041	-118.2583	Plan check for Title 24 only. Project site is a tenant suite on the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 16,120 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60478	17041-10000-26188	1431 W KNOX ST #300	90501	15	057B197   111	7351002029	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	06/16/2018 12:00:00 AM	ADDRESS	33.85442	-118.29964	FULL PC FOR POWER AND ENERGY.  CHANGE OF USE FROM RETAIL TO A RESTAURANT IN A SINGLE STORY BUILDING.  REUSE EXISTING PANELBOARDS, AND PROVIDED NEW CIRCUITRY WITH NEW LOAD  < 200A.(B# 17016-40000-21056)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60479	15041-10001-29241	907 E 3RD ST	90012	14	129A215   266	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	PIN	34.0461867	-118.23487077	### Supplemental PC and Permit to an approved plan. > Changed conductor type from AL to CU to some feeders. > Changed Ufer to Gnd Rod.> Added load less than 400A> New 200A Bus panel> Reduced breaker size from 125A to 100A ahead of LA4A.> Added 400A disconnect ahead of HA5 panel***full plan check for HWS LA, aadaptive rebuild for wharehouse. The original contractor is changed. plan check is required based on new engineer.<<PC FOR POWER AND ENERGY. CHANGE OF USE FROM MANUFACTURING TO GALLERY. ADDITION 1000A TO EXISTIN 1200A SERVICE. TOTAL AREA(CONDITIONED AND UNCONDITIONED) 116005 SQ FT. PHASE 2 OF PROJECT WITH APP# 14041-10000-33875.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60480	14041-10000-00490	1458 S SAN PEDRO ST #L-06	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES TO REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 1125 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60481	17041-10000-40169	12061 W FOOTHILL BLVD	91342	7	213B165   562	2531006009	[T][Q]MR1-1-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.05	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.27812	-118.39864	Remove HID fixtures and replace with new LED fixtures  T-24 only.11500 SQ.FT OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60482	10041-20000-13334	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005019	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM			Corrections Issued	07/13/2010 12:00:00 AM	ADDRESS	34.15303	-118.39667	REVISION TO APPROVED SET OF PLAN UNDER 10041-20000-04562. ADDING NEW TRAILERS. Plan check power to temporary trailers at Campbell Hall school. Circuits in trailers are by others.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60483	14041-20000-12686	10250 W CONSTELLATION BLVD SUITE 2600	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI to (E) commercial office tenant space in a commercial highrise building.  Plan check for TItle 24 for changes to the lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60484	18041-10000-35099	20401 W PRAIRIE ST	91311	12	198B109    91	2748022085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.23922	-118.57764	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60485	16041-20002-05542	5500 N LANKERSHIM BLVD #160	91601	2	174B173  1259	2350008025	C2-2D	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM			PC Approved	02/29/2016 12:00:00 AM	ADDRESS	34.17013	-118.37756	Plan check only for energy per inspector's request.  Total square footage around 1400 sq. ft.  Address previously corrected to 5300 N. Lankershim under 16041-20001-05542	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60486	17041-20000-13124	5711 N LARRYAN DR	91367	3	174B089   176	2045021007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.17503	-118.64798	PV1.  Install 6.24 kW roof mounted grid tied PV system.  AC module standard plan. (26) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60487	11041-10000-05014	3404 W FLORENCE AVE	90043	8	102B185   823	4012017001	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	05/06/2011 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	33.97435	-118.33138	CHANGE OF USE FROM AUTO REPAIR TO CHECK CASH 10 WINDOW TELLER.  PLAN CHECK IS OVER-THE-COUNTER FOR T-24 ONLY.  FULL PLAN CHECK MAY FOLLOW IF REQUESTED BY INSPECTOR.  PLAN CHECK IS FOR BOTH UNIT A & B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60488	17041-20001-16751	662 S KELTON AVE	90024	5	135B149   483	4363014009	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			04/10/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.06503	-118.45264	04/10/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. Elevator has been revised. Elevator electrical load has been reduced. Service load calculations have been revised accordingly.*****Original Work Description*****FULL PC FOR A NEW 12 UNITS  APARTMENT BUILDING. SERVICE SIZE 800AMP. TOTAL AREA OF LIGHTING : 18638 SQ FT.B# 14010-10000-04106	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60489	14041-20000-24576	6600 N TOPANGA CANYON BLVD #1100A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM			PC Approved	09/12/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	Interior TI for retail store in shopping mall.  Plan check for energy only under 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60490	10041-10000-12944	9410 N TOPANGA CANYON BLVD	91311		198B101   137	2746013014	[T][Q]MR1-1		Chatsworth - Porter Ranch	Chatsworth			Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM			Reviewed by Supervisor	07/14/2010 12:00:00 AM	ADDRESS	34.2412	-118.60593	"CHANGE OF USE - PORTION OF BLDG. FROM ""INDUSTRIAL"" TO"" MEDICAL OFFICE""  <<FIRST FLOOR 6484SQFT & SECOND FLOOR 4130SQFT>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60491	19041-20000-28672	8827 N VAN NUYS BLVD	91402	6	195B149   369	2653001007	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Apartment			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	02/17/2022 12:00:00 AM	ADDRESS	34.23074	-118.45052	Plan check for new fire alarm system for new 9 units residential building. 50 Fire Alarm devices and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60492	19041-10000-09171	1518 S ROBERTSON BLVD	90035	5	129B169   453	4303002006	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.05155	-118.38401	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60493	15041-10000-42061	12416 W SANTA MONICA BLVD	90025	11	126B145   938	4267031005	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			12/14/2015 12:00:00 AM			PC Approved	12/14/2015 12:00:00 AM	ADDRESS	34.03876	-118.46695	T-24, TI TO A BEAUTY SALON, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 953. *INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT #15041-10000-39484 AND  APPLICATION #15041-10001-39484.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60494	18041-10001-08316	3489 S MAPLEWOOD AVE	90066	11	114B149  1035	4244022016	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM			PC Approved	04/04/2018 12:00:00 AM	ADDRESS	34.00497	-118.44891	Experdite per applicant  request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60495	17041-10000-33506	555 W 182ND ST	90248	15	063B201   104	7339007028	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	33.87011	-118.28335	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60496	13041-20000-33540	3755 N GOODLAND AVE	91604	2	162B161   584	2384011004	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.13922	-118.40843	New 4.8kw rooftop PV System using Enphase M215 for an existing sfr.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60497	12041-10000-15652	6220 W 3RD ST	90036	4	135B177   585	5509003018	[Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	ADDRESS	34.07057	-118.3565	Plan check for energy only. Low-rise commercial building. 2689 sqft. Occupancy load is less than 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60498	13041-10001-34768	19550 W NORDHOFF ST	91324	12	195B117     9	2783028016	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Closed	07/19/2016 12:00:00 AM	ADDRESS	34.23529	-118.55947	DELTA 16 CHANGES TO PERMITTED SET OF PLANS-NEW 225A PANELBOARD; NEW CKTS; ADDED EV CHARGER CKTS; REFEED SOME LOADS FROM A DIFFERENT PANEL BOARD;  CHANGES TO LIGHTING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60499	10041-10000-16371	515 S FIGUEROA ST 10th Flr	90071	9	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	09/13/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI in an existing office area in Suite #1050 . Plan Check is for T-24 Energy Calcs and Emergency Lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60500	17041-20000-40905	24022 W SCHOENBORN ST	91304	12	192B089   149	2017037017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.22111	-118.64972	pv1install roof mounted pv system sized 5.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60501	18041-20003-44048	5158 N CALVIN AVE	91356	3	171B117   265	2163007023	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.16547	-118.5551	Change of work description: PV1.  Install 12.15 kW AC-CEC rated PV system.  Grid-tied and roof-mounted.  (40) modules with 11.4 kW rated inverter.  Changes to approved plans.  Change to load-side connection and performance meter added.  (((Plan check for a PV1 roof-mounted PV system. System size is 15.6 kWdc/14.4 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (48) modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60502	18041-10001-07688	7540 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM			PC Approved	03/11/2019 12:00:00 AM	ADDRESS	33.94052	-118.42863	Change to approved set  by reducing future load of GSC building. (((PC for powery for LAX delta airlines high bay hangar with one story of office space. Installing new 3000A service, new service quipment, new panels and circuits.    Title 24 and lighthing is under a separate permit MZandi  . B# 18010-10000-00614.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60503	16041-20000-16310	4047 N ELLENITA AVE	91356	3	162B117    47	2180004033	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.14379	-118.55994	PLAN CHECK FOR PV ROOF MOUNTED SYSTEM. SYSTEM SIZE: 15KW WITH 45 MODULE AND 2 INVERTER(7.6KW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60504	18041-20000-09402	14612 W CALVERT ST	91411	6	177A151    14	2241022004	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			03/20/2018 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.18153	-118.45136	Plan check for power and energy. Project site is a new 4-story, 19-unit apartment building. Work includes an 800-amp service and a total lighting area of 14,411 sq. ft.Note: Building permit has been issued under 17010-20000-02238	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60505	16041-10001-28409	18759 W WILLOWTREE LANE	91326	12	207B121   531	2728029070	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.26307	-118.5415	EXPEDITE FEESPV SYSTEM FOR SFD WITH 40 MODULES IN TOTAL. USING AC MODULES. CONNECTED TO EXISTING 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60506	19041-10000-17278	9400 N RESEDA BLVD	91324	12	198B125   151	2764010042	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			05/08/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	34.24136	-118.53589	"NEW ""NORM'S"" RESTAURANT. Conditioned area: 5,477 SF. 1,200Amp Service, New loads & Panels.Plan Check for Power & Energy.Bulding Permit: 19010-10000-01922"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60507	14041-20000-30218	5801-5835 N FIGUEROA ST	90042	1	151-5A229 122	5492012025	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.11031	-118.19186	$0 permit fee due to senate bill 1222 from 2012PV2 INSTALL ROOF MOUNTED PV SYSTEM SIZED 125KW AC/ 161KW DC. THIS IS A FEED IN TARRIF. SYSTEM WILL GET A PV ONLY SERVICE. (576) SOLAR WORLD SW280 MODULES(2) SOLECTRIA RENEWABLES INVERTERSCONDITIONAL USE PERMIT REQUIRED BY PLANNING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60508	19041-10000-13212	10915 1/2 W OTSEGO ST	91601	2	171B173   894	2419002018	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.16305	-118.36873	PC for new 800A , 240/120V, 3W service feeding (10) 200A panels, core and shell only. Per BH (responsible engineer will be provided)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60509	13041-10000-03667	216 S ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.04645	-118.23792	PLAN CHECK FOR REPLACING EXISTING FIRE ALARM SYSTEM. NEW FACP AND DEVICES. PERMIT ISSUED UNDER #13041-10000-01505.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60510	18041-10000-37093	5745 W RODEO ROAD	90016	10	120B173   508	5047002061	R4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.02179	-118.37077	Replacing an existing Fire Alarm system with a new one in an existing school.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60511	18041-10001-12818	5042 E YORK BLVD	90042	1	156A225   332	5477001009	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	34.12108	-118.20551	TI IN AN EXISTING COMMERCIAL AREA. INSTALL NEW LIGHTS. T-24 ENERGY ONLY. 1500 SQR FT.ELECTRICAL PERMIT: 18041-10000-12818BUILDING PERMIT: 18016-10000-05558	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60512	15041-10002-31734	100 WORLD WAY TERMINAL 1-LV 1-ROOF	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	Changes to an approved set of plans. All changes are made under delta 4. Changes include adding 9 FA devices for level 2, revising floor plans, revising battery/voltage drop calculations, and revising floor plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60513	19041-20000-30951	633 W 5TH ST 59th Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only in existing office building Tenant Improvement. Totala area: 15,150 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60514	16041-10000-13746	755 S SPRING ST	90014	14	127-5A211 157	5144015018	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.04336	-118.25369	Installation of a new Fire Alarm system to aparmtent highrise building (29 floors). (1015) Fire alarm devices, (4) FA panels,  (18) Control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60515	11041-10000-07816	8786 N VAN NUYS BLVD	91402	6	195B149   471	2639001020	[Q]CR-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM			PC Approved	04/19/2011 12:00:00 AM	ADDRESS	34.22973	-118.45006	TI FOR KITCHEN AND RESTROOM.  T-24 WITH EMERGENCY LIGHTING.  OTC PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60516	18041-20000-24405	8422 N ZEILER AVE	91402	6	192B157   445	2637014045	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.22368	-118.42536	PV1.  Install roof mounted grid tied  PV system sized 7.6kW interconnected with MSP.    5 kW energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60517	17041-10002-17158	10250 W SANTA MONICA BLVD # 2980	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"2nd revision on approved plan for ""Superdry"", changes noted as delta-7. Scope is to add shunt trip device dedicated circuit for the elevator. Load remain the same."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60518	16041-20001-24899	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	ADDRESS	33.93576	-118.3779	9.1.2016 - Plan check for modifications to approved set. Showing existing panels on SLD and available fault current at each. Replacing existing panels with ones of higher fault current rating where available fault current is >10kAIC -- using series ratings. Provide floor plan to show existing panel locations. Changes clouded delta 6.======Plan check for power and energy Change of use from retail to a restaurant service upgrade 2000 A Service and new panels with some exiting load. Total area: 19,843 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60519	16041-20000-26383	910 S FAIRFAX AVE	90036	4	132B177   328	5086007022	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.05978	-118.36284	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO EXISTING SCHOOL. ADDITION OF COMPUTER CLASSROOM. 427 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60520	17041-20000-31497	15359 W OXNARD ST	91411	6	177B145   440	2242001020	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.17957	-118.46823	Plancheck for power only. Installation of 3 new circuits and replacing some conduits. Replacing low voltage parts. replacing gauges in hazardous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60521	19041-20000-05841	14550 W BURBANK BLVD 1-6	91411	4	174B149   900	2249001002	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			02/19/2019 12:00:00 AM	10/12/2021 12:00:00 AM		Permit Finaled	07/15/2022 12:00:00 AM	ADDRESS	34.17185	-118.45055	T24 PLAN CHECK WITH 400A SERVICE. TOTAL SQUARE FOOTAGE = 5816 SFPERMIT PARTIALLY PAID UNDER19041-90000-0943319041-90000-3386419041-90000-3388518041-10000-35169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60522	17041-20001-34669	13360 W JAVA DR	90210	5	159B157   271	4385004005	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM			PC Approved	01/25/2018 12:00:00 AM	ADDRESS	34.12906	-118.4244	Supplemental to approved set of plans. Changes include reduction of conductor sizing from sub-panel to main panel - inspector to verify conductor and lug rating to be set at 75 degree C minimum. Original permitPlan check for the addition of a battery back-up system to an existing PV system for a single-family home.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60523	18041-10000-39764	403 W 8TH ST	90014	14	127-5A209  57	5144013033	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	06/05/2019 12:00:00 AM		Issued	06/05/2019 12:00:00 AM	ADDRESS	34.0447	-118.2559	PLAN CHECK FOR FIRE ALARM SYSTEM FOR 1 FIRE ALARM PANEL AND 185 DEVICES FOR HIGH RISE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60524	12041-20000-28890	3434 S GRAND AVE	90007	9	118-5A203 116	5122030020	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM			PC Approved	12/03/2012 12:00:00 AM	ADDRESS	34.01912	-118.27658	Plan check for outdoor lighting. USC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60525	14041-10001-14239	2700 S ARMACOST AVE	90064	11	120B153   846	4257016041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.02373	-118.4445	EPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH POWER OPTIMIZER AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60526	19041-10000-34147	4380 N HAYVENHURST AVE	91436	5	165B137   136	2291005023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.15056	-118.49418	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 11.025 PV1 SYSTEM CONSISTING OF 35 AC MODULES(SPR-X22-370-E-AC) CONNECTED TO EXISTING 200A SERVICE MAIN BREAKER DERATE SHALL BE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60527	18041-10000-07613	1360 W ALLISON AVE	90026	1	138A211   119	5405021033	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1976.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	34.07273	-118.25175	PC for T24 only for restuarant TI. Installing new panel, lights, receptacles and equipment. Total area 915sqft. B# 17016-10000-35427.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60528	12041-20000-18249	15655 W ROSCOE BLVD Bldg H	91343	12	192B141   429	2673013032	[Q]CM-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.22155	-118.47417	New roof (Building-H) mounted P.V. system with 25.92 KWdc.Note: Some modules are mounted on Building-F (12041-20000-18243) and Building-G (12041-20000-18246).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60529	11041-10000-19050	15235 S FIGUEROA ST	90248	15	072B201    96	6120028004	C1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	33.89351	-118.28327	T.I. TO AN EXISTING MCDONALDS FOR INDOOR/OUTDOOR LIGHTING.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60530	11041-10000-20656	1007-1013 E ELKGROVE AVE BLDG 42	90291	11	111B145   692	4243003038	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.00023	-118.45972	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60531	13041-10000-30173	4451 N PORTOLA AVE	90032	14	147A235    47	5307004002	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.10	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	ADDRESS	34.0985	-118.17062	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING WITH EXISTING 100A MAIN SERVICE. WORK IS DONE ON A MICROINVERTER STANDARD PLAN WITH 10 MODULES (AU OPTRONICS; PM 250MOL-260W) , 10 ENPHASE M215 MICROINVERTERS (M215-60-2LL-S2X) ON ONE STRING.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60532	19041-10000-23574	7323 N COLDWATER CANYON AVE	91605	2	186B161   555	2327016006	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Issued	06/20/2019 12:00:00 AM	ADDRESS	34.20377	-118.41396	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60533	12041-20000-03809	2705 E MEDIA CENTER DR BLDG 2	90039	1	150B213  3654	5442032002	[Q]M2-1-CDO, [Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM			PC Approved	02/24/2012 12:00:00 AM	PIN	34.11002685	-118.24478343	T. I.Energy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60534	10041-10000-10348	1458 S SAN PEDRO ST # L50	90021	9	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	08/31/2010 12:00:00 AM	PIN	34.03045627	-118.25434986	tenant improvement in existing retail storeplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60535	14041-20001-03781	11614 N HERRICK AVE PV1	91340	7	213B157   313	2524019029	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.28132	-118.42541	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL. 4.75 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS, WITH (19) trina SOLAR #tsm-250pa05.18, (19) OP300-MV, (1) 5000A-US-ZB-U SOLAREDGE INVERTERS,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60536	10041-10000-03544	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM			PC Approved	03/01/2010 12:00:00 AM	ADDRESS	34.07666	-118.3805	new primary feeder ( about 15 ft ) from existing pull box  thru existing 400A/3P with  175A trip CB  to primary of existing 112.5KVA transformer which is connected to existing ATS-1 400A.  ALL IN THE ATRIUM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60537	11041-10000-09301	8600 S CENTRAL AVE	90002	9	097-5A209 255	6043001027	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			05/06/2011 12:00:00 AM			PC Approved	06/29/2011 12:00:00 AM	ADDRESS	33.95988	-118.25616	Ti in an existing 7-11 store. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60538	16041-20000-32062	2029-2049 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for energy only. Replacing lighting (incl. emergency) for underground parking garage - 6 levels. All circuits existing. 2,062,896sqft total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60539	17041-10003-09270	18521 W DEVONSHIRE ST	91324	12	204B125   100	2728028025	C2-1, C2-1VL, P-1VL, PB-1, RE15-1-H	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.25744	-118.53722	TEMPORARY INSTALLATION OF AN  ELECTRIC WATER HEATER IN ORDER FOR THE RESTAURANT TO HAVE PORTABLE HOT WATER AS REQUIRED BY CODE. THERE WAS A DELAY IN HAVING A GAS LINE FOR THE GAS WATER HEATER((((((((Plan check for power and energy for new restaurant Chick-Fil-A 1200A Service 1 story. Total area: 5,279 sq ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60540	16041-10001-45280	450 S WESTERN AVE 221	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM			PC Info Complete	07/05/2017 12:00:00 AM	ADDRESS	34.06562	-118.30887	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2. UPDATE HOME RUNS AND REARRANGED A COUPLE OF PANELS ON SINGLE LINE. VALUE ENGINEERED FEEDER AND TRANSFROMERS. PERMIT ISSUED UNDER THIS APPLICATION FOR 2 NEW PANELS. UPDATED LIGHTING PLAN AND TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60541	17041-10000-07100	1150 S OLIVE ST 24TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	11/01/2021 12:00:00 AM	ADDRESS	34.03962	-118.26181	T-24, PC FOR ENEGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 24TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3214 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60542	19041-10000-36901	22122 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.1863	-118.60916	PC FOR POWER AND ENERGY. TOTAL AFFECTED AREA 21890 SQ FT. NEW HVAC LOADS, AND REVISING LOADS ON EXISTING PANELBOARDS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60543	15041-20000-20541	18618 W CALAHAN ST	91324	12	198B121   756	2763013007	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.23627	-118.53892	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60544	16041-20000-41241	11601 W WILSHIRE BLVD Ste 2200	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60545	17041-20000-29877	1965 N HILLHURST AVE	90027	4	150B197   560	5590012045	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Issued	08/22/2017 12:00:00 AM	ADDRESS	34.10719	-118.28759	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.partial permit fees paid under application number 17041-20000-22567.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60546	13041-20000-10935	8500 W BEVERLY BLVD #702	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	T24 FOR WETZEL PRETZEL AT BEVERLY CENTER (SPACE #702). 638 SQRFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60547	19041-10000-27541	2619 N FIGUEROA ST	90065	1	142-5A219 129	5446010023	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.08438	-118.22201	Full plan check for a core/ shell only for a 2-story commercial building. Scope include (1) 2500-Amps service, subpanels, equipment, and outdoor lighting. area of scopr is 5,610sf	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60548	11041-10000-04401	1306 N L. RON HUBBARD WAY	90027	13	147B197  1062	5543016019	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM			Verifications in Progress	10/06/2011 12:00:00 AM	ADDRESS	34.09574	-118.29377	TI FOR COMMERCIAL BUILDING.  FULL PLAN CHECK ON AN EXISTING 4-STORY BUILDING.  FIRE-ALARM WILL BE FILED UNDER A SEPERATE APPLICATION.***Permitted under 13041-10000-05577, finaled on 2/12/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60549	18041-10000-28345	3921 N LAUREL CANYON BLVD	91604	2	162B165   437	2369013019	R1-1-RFA-RIO, R1-1VL-RFA-RIO, [Q]RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM			PC Approved	07/27/2018 12:00:00 AM	ADDRESS	34.14179	-118.39477	PC FOR ENERGY, FIRE ALARM SYSTEM TENANT IMPROVEMENT INSTALL DEVICES IN CLASSROOM BLDG. EXISTING ELECTRICAL FIRE ALARM PANEL WITH NEW DEVICES. PERMIT FEES HAVE BEEN PAID UNDER 18041-10000-04568	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60550	18041-10000-27721	7662 W MELROSE AVE	90046	5	141B177   639	5527023025	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.08351	-118.35688	T-24, PC FOR ENERGY ONLY. CHANGE OF USE OF (E) OFFICE TENANT SPACE TO COFFEE SHOP. SCOPE INCLUDES NEW 125A PANEL, NEW LIGHTS, AND RECEPTACLES. TOTAL AFFECTED AREA IS 971 SQ. FT. B#18016-10000-16819	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60551	15041-20000-07583	13701 N DE GARMO AVE	91342	7	228B145   814	2501014045	OS-1XL-K, RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.32034	-118.46978	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Two inverter system with 32 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60552	14041-20000-05266	14440 W BURBANK BLVD	91401	4	174B149   910	2245007027	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1285.00	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.17189	-118.44778	T.I. to portion of interior lighting.  Plan check for energy only.\Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60553	09041-10001-05817	2117 W TEMPLE ST	90026	13	138A205   278	5157016031	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10, 2085.00	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.07062	-118.26858	This is building A located on corner temple and lake.  original address by mistake was given by applicant --711 s. new hampshire. Plan check under pcis # is 07041-10000-26288.((((((((((((((((((((((((((((((((((((((((((2-26-10 -------------- application 07041-10000-26288 was withdrawn by mistake by applicant and permit was isued in december 31st  09  without plan check therefor this supplemental plan check reflect new changes and  permit number remains as X09LA04863. )))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60554	16041-10000-21582	806 W 133RD ST	90247	15	078B197   164	6117031014	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	33.91116	-118.28974	PV1, rooftop solar installation 6kW AC system.  (30) KU2656ZPA    (1) PVI-6000-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60555	13041-10000-06157	3000 S HOOVER ST	90007	9	121-5A201 144	5123005031	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.02712	-118.28376	revisions to approved set of plansPLAN CHECK FOR POWER AND ENERGY FOR A NEW FIRE STATION #15. NEW 1000A SERVICE. INDOOR SQRFT: 15944 OUTDOOR SQRFT: 26617.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60556	14041-10000-32463	374 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	33.93089	-118.2669	Per�Senate�Bill�No.1222, Fee cap reached, thus fee is $0.PV2, INSTALL  15.68 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMERCIAL  BUILDING. INTERCONNECT WITH MAIN SERVICE PANEL. 6 STRINGS.(2) INVERTERS:  DELTA-SOLIVIA 7.6TL (56) MODULES: LDK SOLAR LDK-280P-24	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60557	16041-10000-39542	3116 W AVENUE 32	90065	13	154-5A213 177	5458012011	CM-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Closed	11/28/2023 12:00:00 AM	ADDRESS	34.11683	-118.24348	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR (E) OFFICES; NEW OFFICE LAYOUT FOR FIRST FLOOR OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 9160 SQ. FT.  B#16016-10000-24968	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60558	17041-10000-22458	6922 W HOLLYWOOD BLVD 3rd FLOOR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.10137	-118.34103	PC FOR RESTROOM AND ELECTRICAL ROOM TI IN A HIGH RISE (3RD FLOOR) FOR TITLE 24  ENERGY ONLY. TOTAL AFFECTED AREA  403 SQ.FTINSTALLING NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60559	13041-20000-07995	11315 W OXNARD ST	91606	2	177B173  1093	2337009027	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Apartment			03/28/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.17956	-118.37745	solar system apartment 8-10k inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60560	17041-10000-13157	8133 W ELLENBOGEN ST	91040	7	210B193   225	2551018053	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.2721	-118.31065	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012Installation of new roof mounted solar PV array on existing single family dwelling.  Two inverter system.  Total system size = 15 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60561	11041-10002-23947	445 N MANSFIELD AVE	90036	5	141B181  1289	5524029022	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2012 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	03/21/2012 12:00:00 AM	ADDRESS	34.07961	-118.34091	USING A 4KW AND A 7KW INVERTERS TO REPLACE THE 11.4KW INVERTER; THIS WILL RESULT IN LESS WIRING;ALSO THE EXISTING SUBPANEL IS UPGRADED TO A 200A PANEL  AND A 60A DISCONNECT ADDEDRevision to approved plans: Interactive point of connection relocated to sub-panel from main service panel.(New 12.42KW,Rooftop, Photovoltaic System for a single family residence.   54 pv panels and one inverter with 6 strings of 9 pv panels going to the inverter.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60562	12041-10000-04872	8900 N DE SOTO AVE BLDG 106	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.23162	-118.58832	PLAN CHECK FOR NEW INSTALLATION OF 400KW FUEL CELL IN BUILDING #106. INCLUDES MEDIUM VOLTAGE INSTALLATION. ROCKETDYNE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60563	15041-20001-21197	10570 W ART ST	91040	7	201B177   192	2542018021	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.24845	-118.36018	Expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 13.5 kWac.  Two inverter system.  One inverter is connected so existing subpanel and one is connected to new main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60564	12041-10000-13638	1936 E 1ST ST	90033	14	129A221   303	5174016031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.04587	-118.21637	Plan check for power and energy. Shell for medical building. 1410 outdoor sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60565	10041-10000-02703	11156 W SHERMAN WAY	91605	2	183B173   115	2319022008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Finaled	05/13/2010 12:00:00 AM	PIN	34.20067748	-118.37435243	T.I. for office area.  Install general and emergency lighting.  Plan check for Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60566	18041-10000-08202	2009 S RAYMOND AVE	90007	1	126B197  1084	5075032011	R3-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Apartment			03/06/2018 12:00:00 AM			Reviewed by Supervisor	04/09/2018 12:00:00 AM	ADDRESS	34.03791	-118.29761	FULL PC FOR POWER AND ENERGY TO A NEW 4-STORY (10) UNIT APARTMENT BLDG  WITH ROOF DECK. 800 AMP, 120/240, 3PHASE, 4W TOTAL SQ. FT. 7000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60567	18041-10001-24198	6360 W 80TH PL	90045	11	099B165   714	4108026034	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	33.96605	-118.39833	EXPDITE PER APPLICANT REQUEST FOR PV PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60568	13041-20000-19512	1018 S TREMAINE AVE	90019	10	132B185   677	5083004013	R1-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.05636	-118.33743	pv1 single family dwelling. total system size 5.8kw using 24 modules. nonstandard plan. 3 strings.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60569	12041-20000-18401	14006 W RIVERSIDE DR 39B	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM			PC Approved	09/06/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I. to retail space 39B.  Install general/emergency lighting with Tailor Method.  Plan check for energy only. Sketchers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60570	14041-20000-25603	1480 N ARMADALE AVE	90042	14	157-5A223  62	5476020005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.12454	-118.21136	PV1.  Install 7.848 kW roof-mounted, utility-interactive PV system.  (2) 3.8 kW transformerless inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60571	14041-20000-29699	1007 W SANDWOOD PL	90731	15	027B197    39	7442006002	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	33.76555	-118.29983	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(18) SUNPOWER E20 327 MODULES(1) AURORA PVI-6000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60572	12041-10000-14178	9019 S AIRPORT BLVD	90045	11	093B169     5	4123018928	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	ADDRESS	33.95367	-118.38613	Plan check for energy. Outdoor parking lot. 72386 sqft. LAX Jenny Lot	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60573	18041-10000-41053	1453 N ALVARADO ST	90026	13	141A207    64	5424001028	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1955.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.08199	-118.26097	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60574	13041-20001-11121	6201 N TOPANGA CANYON BLVD	91367	3	177B101    44	2146001022	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.18313	-118.60616	((Changes made to approved set of plans. Made some substitutions for some lights.))Full plan check for change of use to restaurant. Occupancy load is greater than 100. Hook Burger.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60575	19041-10000-03691	3411 W OLYMPIC BLVD	90019	4	129B193   286	5081032021	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.0528	-118.3126	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60576	13041-10001-31456	5464 S WEST BLVD	90043	8	108B185   624	5007019017	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	33.99115	-118.33541	Expedited RSES plan check per applicant request.(((PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 16 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60577	17041-20000-29751	7601 N WHITE OAK AVE	91335	12	186B129   218	2120002031	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.20879	-118.51879	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 670 sq. ft.Note: Building permit has been issued under 17016-30000-11822	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60578	18041-20000-00918	19191 S VERMONT AVE Suite 405	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	Plan check for Title 24 only. Project site is an suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,154 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60579	13041-20001-10213	6600 N TOPANGA CANYON BLVD #9036	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM	06/19/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	((Supp application for plan check and permit. Per inspector request, pc for loads for kiosk desk. permit issue for difference from original permit. )))200 SQ FT KIOSK INTERIOR T.I. FOR WESTFIELD TOPANGA MALL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60580	11041-20000-08289	21550 W OXNARD ST 420-430	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.179	-118.60001	TI TO AN EXISTING OFFICE BUILDING ON THE 4TH FLOOR SUITES 420-430.  T-24 WITH EMERGENCY LIGHTS, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60581	14041-20000-18816	15928 W SUNBURST ST	91343	12	195B141    76	2672005065	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Expired	08/17/2016 12:00:00 AM	ADDRESS	34.23455	-118.47941	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.6KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60582	16041-20000-42386	3531 W SUNSET BLVD	90026	13	144A203   129	5429024013	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.08971	-118.27667	12/02/2016 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 556 sq. ft.Note: Building permit has been pulled under 16016-30000-23945	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60583	15041-10000-03060	21700 W DEVONSHIRE ST	91311	12	204B105   306	2747015079	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.25707	-118.60183	PC FOR ENERGY ONLY.CHANGE OF USE FROM MEDICAL OFFICE TO A LOAN OFFICE. TI. TOTAL AREA 2205 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60584	16041-20000-36609	4530 N BAKMAN AVE	91602	2	168B173  1009	2366001023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.15307	-118.37776	PV1.  Install roof mounted pv system sized 10.1kw interconnected with msp.  Enphase S280 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60585	16041-20000-31964	5200 S CENTRAL AVE	90011	9	108B209    95	5104003034	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	33.99574	-118.25623	$0 permit fee per State Senate Bill SB 1222.  Plan check for the roof-mounted portion of a PV2 roof-mounted & ground-mounted PV system. PV is part of the LADWP feed in tariff (FIT) program. Roof-mounted portion is 56 kWac and consists of (2) 28 kWac inverters and (226) modules. Total system size is 323 kWac.  Note: Ground mounted portion of the PV2 PV system can be found under application number 16041-20000-31971	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60586	19041-20000-52866	11100 S CENTRAL AVE	90059	15	088-5A211 534	6070006010	C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	Watts		2426.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	33.93513	-118.254	Fire alarm system for multibuilding campus with voice evacuation.  FACP, cellular communicator, annunciator, and (384) signaling line and notification devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60587	10041-20000-05697	6845 N VINELAND AVE	91605	2	183B173   231	2319005022	M1-1VL, M2-1VL	South Valley				1232.06	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM			Corrections Issued	03/30/2010 12:00:00 AM	ADDRESS	34.19522	-118.37051	electrical service ( from building 6831 N Vineland ) to fire damaged building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60588	19041-20003-12664	10252 N TUNNEY AVE	91324	12	204B117   203	2726016001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM			PC Approved	08/12/2019 12:00:00 AM	ADDRESS	34.25689	-118.55782	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY CHANGES ON CRITICAL LOADS.<<<Installation of 13.5 kWh energy storage system and associated distribution/critical load panel.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60589	14041-10000-07228	3323 W PICO BLVD	90019	10	129B189   986	5081022029	C4-1-O	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM			Ready to Issue	03/25/2014 12:00:00 AM	ADDRESS	34.04732	-118.3164	CHANGE OF USE FROM OFFICE TO RESTAURANT. (SUBWAY ) 960 SQ FT.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60590	14041-20000-08379	7856 N MARY ELLEN AVE	91605	2	189B161   711	2303025007	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.2134	-118.41753	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 4.16 KQ DC(16) ENPHASE M15 MICROINVERTER(16) SW 260 MONO MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60591	14041-20001-08218	6600 N TOPANGA CANYON BLVD #2072	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	Changes from previously approved.  Change include branch circuits and lighting.  All changes are clouded with DELTA 2 as shown on plans.  Plan check for power and energy.Note: Approved plans submitted for reference only.*****Previous Description*****PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT RETAIL STORE.  Change of use , 30 days variance submitted in liu of load sduy in accordence to article 220-87.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60592	10041-10000-24507	16422 W VENTURA BLVD	91436	5	168B137   401	2284002055	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.15707	-118.49064	TI in commercial building. EPC is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60593	10041-10000-00608	13630 W VICTORY BLVD	91401	2	180B157   958	2330012022	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	Public Safety Only			01/13/2010 12:00:00 AM	01/13/2010 12:00:00 AM		Permit Finaled	02/04/2010 12:00:00 AM	ADDRESS	34.1865	-118.43001	New Fire Alarm system for Valley Thrift Store.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60594	11041-10000-25403	12200 W OLYMPIC BLVD	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	12/16/2011 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.03195	-118.45506	Ti , commercial, title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60595	13041-10000-11540	196 E JEFFERSON BLVD	90011	9	118-5A205 315	5120007006	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			Corrections Issued	05/03/2013 12:00:00 AM	ADDRESS	34.01717	-118.26972	TI for fabric-drying commercial bldg.  Single story,  ~7000 sq ft.  T24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60596	14041-10000-01570	15200 W MORRISON ST	91403	4	168B145   116	2263017035	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.16019	-118.46417	PV1, Install 6.25 kW DC roof-mounted solar array, interconnect with exsisting service panel. (1) Transformerless inverter(s):n Solaredge SE6000A-US. (25) Modules TRINA SOLAR TSM-250PA05.18.(25) Optimizer:SOLAREDGE OP250-LV-MC4SM-2NA-Z.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60597	13041-20000-30611	1122 S GAYLEY AVE	90024	5	132B149   108	4363023030	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.05976	-118.44586	NEW FIRE ALARM SYSTEM. 196 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60598	12041-10000-07993	452-458 S MAIN ST	90013	9	129A211   157	5148009015	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	06/20/2012 12:00:00 AM	ADDRESS	34.04697	-118.24801	PLAN CHECK FOR NEW 30KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM INSTALLATION FOR APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60599	14041-20000-34679	1000 W WILSHIRE BLVD SUITE 1690	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	PC FOR T24 ENERGY ONLY. LUMINAIRE RPLACEMENT. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60600	17041-20000-43289	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	Yes	1816.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.12626	-118.21412	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of a new medium-voltage distribution section on an existing medium-voltage service. Section will be used for the installation of new current transformers onto (4) existing feeders.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60601	17041-10000-03748	1635 N BLUE JAY WAY	90069	4	147B169    57	5561026013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM			Reviewed by Supervisor	02/15/2017 12:00:00 AM	ADDRESS	34.10272	-118.38708	Plan check for PV roof mounted battery backup system on SFD. System size: 15.0kW with 60 modules HYUNDAI HISM250MG and 2 inverters(7.5kW) SOLAR EDGE, 2 (5kW) Battery back up by Tesla Power Wall Home connected to 800A Swtich gear.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60602	17041-10000-37331	10887 W LINDBROOK DR	90024	5	132B153   246	4363022009	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			PC Info Complete	10/17/2017 12:00:00 AM	ADDRESS	34.05992	-118.44422	Plan check for T24 only, TI on the facade of the existing building, replacing all exterior lights with new one. Total area of scope: 842 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60603	10041-10000-20702	928 S WESTERN AVE # A-3	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.05485	-118.30886	T-24 ( and emergency lighting) for remodeled space A-3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60604	19041-10000-03615	6001 W 96TH ST ITF WEST-Station	90045	11	093B169   328	4124019***	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Issued	01/09/2020 12:00:00 AM	ADDRESS	33.94898	-118.38948	NEW WEST INTERMODAL TRANSPORTATION FACILITY (ITF WEST) STATION FOR LAX AUTOMATED PEOPLE MOVER PROJECT FOR EXITING , GREEN, DAD AND ZONING REVIEW ONLY.Building Permit: 18010-10000-04883	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60605	12041-20000-30144	1742 N INDIANA AVE	90063	14	135A229   146	5224007005	M3-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	PIN	34.0628459	-118.1922516	New 4000 amp service upgrade for an existing steel  fabrication manufacturer.  No classified areas per applicant.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60606	19041-10000-23271	11280 W PEACH GROVE ST	91601	2	168B173   296	2353022079	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Apartment			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	01/10/2021 12:00:00 AM	ADDRESS	34.15901	-118.37715	INSTALL FIRE ALARM SYSTEM FOR NEW 21 UNITS IN APARTMENT BUILDING WITH 65 DEVICES AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60607	15041-10000-16164	14100 N JANNA WAY	91342	7	231B161    20	2582024019	RE11-1-H	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.32841	-118.41098	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.5KW INTERCONNECTED WITH MSP. Scope include (18) Solar World-285 modules and (18) Enphase M250 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60608	14041-10000-21728	5525 W SUNSET BLVD	90028	13	147A193   102	5544023023	C2-1	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Expired	09/12/2016 12:00:00 AM	ADDRESS	34.09826	-118.31015	Replace fire alarm panel, add cellular fire alarm communicator, replace 3 existing smoke detectors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60609	18041-10001-48197	442 S SAN PEDRO ST	90013	14	127-5A213 135	5147007020	PF-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.04464	-118.2434	SUPPLEMENTAL FOR FEE EXPEDITEPLAN CHECK FOR ROOF MOUNTED 11.5KVA SYSTEM CONSISTING OF 2 CENTRAL INVERTERS(TS208-5K75) WITH 36 MODULES(RECOM RCM-325-6MA(325W)) CONNECTED TO EXISTING 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60610	19041-20000-21949	4720 N RADFORD AVE	91607	2	168B169   629	2355019024	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Apartment			06/10/2019 12:00:00 AM			Reviewed by Supervisor	08/07/2019 12:00:00 AM	ADDRESS	34.15643	-118.39194	POWER AND ENERGY PLAN CHECK FOR NEW (12) UNIT APARTMENT BUILDING. SERVICE SIZE OF 800A. SCOPE OF WORK INCLUDES (5) TYPICAL UNIT TYPES, A 40HP ELEVATOR. (15) 125A PANEL, AND A 200A PANEL. T24 INCLUDED TOTAL SQUARE FOOTAGE = 15,161 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60611	11041-20000-21012	10940 W WILSHIRE BLVD 10th floor	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/03/2011 12:00:00 AM	ADDRESS	34.05822	-118.4452	Remodel of an existing corridor on the 10th floor.  The remodel is for the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60612	15041-10000-00712	1640 S SEPULVEDA BLVD	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	01/12/2015 12:00:00 AM		Issued	01/12/2015 12:00:00 AM	ADDRESS	34.04838	-118.44468	Changes to lighting system in elevator lobbies of (E) 5-story commercial office building.  Plan check for energy.  P1, 1ST FL, 2ND FL, 4TH FL, 5TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60613	17041-20001-34165	14337 W JOY DR	91331	6	198B149   660	2644027250	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24135	-118.44589	Revision to approved set.  Change to higher power module type and inverter rating increased to 3.8 kW AC.  (((Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60614	15041-10007-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	10/29/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET. CHANGES ARE NOTED UNDER DELTA 37.SCOPE INCLUDES REVISION TO FLOOR PLANS (PANELS LOCATIONS), REVISION TO SINGLE LINE TO REFLECT CORRECT PHYSICAL LOCATION OF EXISTING PANEL.REFERECING APPROVED SET UNDER SUPP 10004 APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60615	19041-30000-05400	10000 W PICO BLVD	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.05211	-118.40654	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,928 sq. ft.Note: Building application has been generated under 18016-30000-41225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60616	15041-10000-29227	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			PC Approved	09/03/2015 12:00:00 AM	ADDRESS	33.94221	-118.40701	Pc for energy only for a commercial bldg. Scope of work: TI convert an open area to small room for nursingsq ft 61 sqftpayment through ido, authorization # 4500279324	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60617	11041-20000-20250	7060 W HOLLYWOOD BLVD Ste 110	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			Not Ready to Issue	12/08/2011 12:00:00 AM	ADDRESS	34.10137	-118.34379	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60618	19041-10000-26108	1330 S FEDERAL AVE 1-16	90025	11	129B149   857	4263015069	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.03	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	01/26/2021 12:00:00 AM	ADDRESS	34.04752	-118.45624	INSTALL (120) NEW FIRE ALARM DEVICES, AND (1) FIRE ALARM PANEL IN APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60619	15041-20001-30512	6248 N TEESDALE AVE	91606	2	177B161   199	2332013003	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	34.18442	-118.40828	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. A 3.6 kWac system is being added to an existing 5 kWac system for a total system size of 8.6 kWac. 3.6 kWac system consists of (1) inverter, (17) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60620	18041-10000-30633	13300 W BURBANK BLVD	91401	4	174B157   645	2344014007	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.17196	-118.42291	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60621	12041-20000-15583	22700 W SHERMAN WAY	91307	12	183B097   111	2024019005	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM			Reviewed by Supervisor	07/17/2012 12:00:00 AM	ADDRESS	34.20071	-118.62196	solar system roof of carport	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60622	18041-10000-12900	1500 W PALOS VERDES DR	90732	15	030B193   246	7442001033	RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	9800.15	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	33.77954	-118.30313	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60623	18041-10000-41277	1336 W 36TH PL	90007	8	120B197  1087	5040009028	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.02177	-118.29862	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60624	18041-30001-37527	7265 W MELROSE AVE	90046	5	141B181   541	5525012013	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.08365	-118.348	03/19/2019 Changes to an approved set of plans. Emergency egress fixtures have been changed to wall-mounted units (unit equipment). Recessed fixtures in dining area have been changed to pendants. Wattage rating has remained the same.*****Original Scope of Work*****Plan check for T24 only, TI to an existing commercial building.  adding new lighting new controls to new panels.  Total area: 1862 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60625	16041-10000-02398	1600 N VINE ST	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.1	-118.32647	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON THE 6TH FLOOR. SCOPE INCLUDES NEW LIGHTS FOR AN EXISTING COUNTER-TOP ON THE 6TH FLOOR. TOTAL AFFECTED AREA IS 210 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60626	11041-10001-10082	3724 E MISSION ROAD	90031	1	136-5A227  61	5211020021	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM			Corrections Issued	01/18/2012 12:00:00 AM	ADDRESS	34.06862	-118.20047	Modification to previously approved set of plans.  Change to use smaller AC units and 3 smaller panels.  <<<<new 7-11, TI, power, energy, lighting . all new work.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60627	11041-10000-05028	5400 W CENTURY BLVD	90045	11	090B173   134	4129030041	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM			Corrections Issued	04/12/2012 12:00:00 AM	ADDRESS	33.9451	-118.37436	REMODEL TO EXISTING HOTEL LOBBY, CHANGING LIGHTS OVER BAR AREA.  T-24 ONLY PLAN CHECK OVER COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60628	19041-10000-07858	1875 S CENTURY PARK EAST SUITE#1450	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.06115	-118.41457	PLAN CHECK FOR TITLE 24 ONLY TENANT IMPROVEMENT FOR COMMERCIAL OFFICE TOTAL EFFECTED AREA 2062 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60629	13041-20001-27747	20362 W SCHOENBORN ST	91306	3	192B113   530	2781028035	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.22091	-118.57726	((Expedite fees)))((NUMBER OF MODULES HAVE NOT CHANGED. ZONING WAS CHECKED ON ORIGINAL APPLICATION#: 13041-20000-24220))pv1 single family dwelling. total system size 8.6 kw ac using 36 modules. 2 central inverter nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60630	18041-20000-07169	9356 N LEMONA AVE	91343	7	198B149   174	2650034056	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.24086	-118.45871	New fire alarm system for 2 buildings.  Scope of this permit is for administration building.  (50) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60631	14041-10000-18046	1947 N CAHUENGA BLVD	90068	4	150A187    67	5575002002	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.10686	-118.33085	PLAN CHECK FOR ENERGY ONLY FOR EXISTING RETAIL SPACE. PERMIT HAS ALREADY BEEN PULLED, THIS IS A PLAN CHECK APPLICATION ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60632	14041-10000-06735	12849 W GREENE AVE	90066	11	108B157  1696	4223015025	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	33.98797	-118.42991	PV1, INSTALL 2.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A(10) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60633	15041-20000-30653	10815 W MISSOURI AVE	90025	5	129B153   620	4321001159	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.04902	-118.43433	NEW FIRE ALARM SYSTEM ON EXISTING 4-STORY, 8 UNIT APARTMENT BUILDING. SCOPE INCLUDES 1 FIRE ALARM PANEL, 1 COMMUNICATION PANEL, 1 CONTROL PANEL, AND 38 FIRE ALARM DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60634	15041-10000-13712	19803 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	33.85112	-118.28659	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 2688	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60635	15041-10000-33033	810 E PICO BLVD 301-303	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.03119	-118.25079	T-24. PC for energy only to an existing commercial building. Existing service and equipment. Installing new lighting and receptacles. Sq Ft = 9590.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60636	19041-10000-33654	13160 W MINDANAO WAY SUITE 301	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.98501	-118.43726	FULL PLAN CHECK FOR A TI TO UCLA HEALTH MEDICAL OFFICE SUITE 301. (NO SURGICAL OPERATIOS)SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 5089 SQ.FTB#19016-10000-26004	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60637	11041-10000-24408	1850 N WHITLEY AVE 1-202	90028	13	150A187   270	5547005019	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.10468	-118.3332	Replacing EXISTING  5KV CABLE AND  AND TAP SWITCHES ( ON EACH FLOOR); EXISTING CONDUITS TO BE REUSED; TAP SWITCHES WILL NOT BE OILED FILLED AS THE OLD ONES WERE.ELECTRICAL RATING WILL BE SIMILAR TO THE REPLACED ELECTRICAL EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60638	11041-10002-10296	1025 N HIGHLAND AVE 14th fl	90038	4	144B185   830	5532028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM			PC Approved	08/20/2012 12:00:00 AM	ADDRESS	34.08969	-118.33884	Revision to the approved plan. Remove the raised floor in the lab, relocate a panel, and add new Ckts. ((((((((((((((((((((((((((FIRST TIME TENANT.  ALL NEW ELECTRICAL FOR 14TH FLOOR.  DISTRIBUTUION PANELS, XFRMRS, LIGHTING AND POWER.  APPLICANT WILL FILE FOR VARIANCE TO SEPERATE FIRE-ALARM.))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60639	10041-10001-14406	2416 E 24TH ST	90058	14	117A217    41	5168020006	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM			PC Approved	11/15/2010 12:00:00 AM	ADDRESS	34.01614	-118.22959	DELTA 1 CHANGES TO APPROVED PLANS FOR THE NEW LOCATION OF SERVICE EQUIPMENT.   NEW 600 AMP SERVICE. PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60640	12041-10000-21642	6555 W IMPERIAL HWY	90045	11	087B165   123	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	33.93206	-118.40322	TI in an existing warehouse. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60641	17041-10000-43204	4520 W WILSHIRE BLVD	90010	4	132B185    44	5090014030	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Issued	12/06/2017 12:00:00 AM	ADDRESS	34.06175	-118.32792	REMOVE OUTDOOR HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60642	15041-10000-12713	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	33.98489	-118.42552	REMOVE STRIPLIGHT AND INSTALL NEW LED LIGHT FIXTURES AND WALL SWITCH SENSOR.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60643	16041-10000-10262	12777 W JEFFERSON BLVD BLDG E	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	33.9778	-118.41768	PC FOR A NEW METHANE GAS DETECTION SYSTEM FOR A THREE STORY COMMERCIAL BUILDING. SCOPE INCLUDES 1 GAS DETECTION CONTROL PANEL, 3 HORN STROBES, AND 13 GAS SENSORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60644	17041-20000-03101	3397 N BARHAM BLVD	90068	4	159B181   187	5579007022	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	06/11/2021 12:00:00 AM	ADDRESS	34.1333	-118.34402	PLANCHECK FOR POWER AND ENERGY. new three story commerial building 800 amp service.  building permit # 14010-20000-01950	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60645	14041-20000-19120	3722 S OCEAN VIEW AVE	90066	11	114B153  1063	4248031022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.00619	-118.43369	Standard Plan: 3.4KW PV1 roof-mounted microinverter system. with (16) SolarWorld SW250 Mono  modules and Enphase M215 mircoinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60646	11041-10000-16593	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI TO AN EXISTING HIGH-RISE OFFICE.  PLAN CHECK IS FOR ENERGY ONLY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60647	12041-10000-22942	10819 W WESTMINSTER AVE	90034	11	120B161  1072	4252037022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2012 12:00:00 AM	09/26/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.02247	-118.41394	Permite only for a new 1.98 kw roof mounted PV for a single family. Plan check for this job was done under app.# 12041-10000-20541, because the change of address. (transformer lees INV with power optimizer) permite fee is under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60648	13041-10000-20169	523 W 6TH ST SUITE 203	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Approved	07/31/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	Office TI in PACMUTUAL BUILDING.  Voice and data cabling, replacement of lighting fixtures.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60649	18041-20000-45399	9903 W ANTHONY PL	90210	5	150B157   221	4356004009	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Expired	09/05/2023 12:00:00 AM	ADDRESS	34.10365	-118.43199	Plan check for  PV roof mounted system and Energy Storage System, system size: 7.32kW with 1 inverter(6.0kW) with 24 PV Modules and Tesla Power Wall 2.0 13.5kWh Energy Storage.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60650	18041-20000-33835	9947 N VENA AVE	91331	6	201B157    79	2645006039	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.25102	-118.43143	Plan check for a PV1 roof-mounted PV system. System size is 2.32 kWdc/3 kWac and consists of (1) inverter and (15) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60651	15041-10000-09734	7347 N ATOLL AVE	91605	2	162B165   263	2369002022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.20424	-118.42119	TI TO AN EXISTING SINGLE STORY COMMECIAL BUILDING.  RETOFIT EXISTING LIGHTING TO LEDS.  PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FOOTAGE 3433	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60652	13041-20001-35917	11734 W REMINGTON ST	91342	7	213B169   484	2531023029	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.28107	-118.38847	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60653	18041-10001-26579	7270 WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Info Complete	01/09/2020 12:00:00 AM	ADDRESS	33.94145	-118.42037	SUPPLEMENT TO AN APPROVED SET. SCOPE INCLUDES REMOVAL OF 400A SERVICE, AND REDIRECTING POWER FROM EXISTING SERVICE. ORIGINAL PLAN CHECKER IS MEHDI.****PLAN CHECH FOR POWER AND ENERGY FOR SECURED ACCESS POST(SAAP) AT WORLD WAY WEST POST 21. TOTAL AFFECTED AREA = 216181 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60654	16041-10002-32532	8465 N CRANFORD AVE	91352	6	192B165   270	2634040020	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM			PC Approved	11/03/2016 12:00:00 AM	ADDRESS	34.22454	-118.4004	11/03/16Changes to an approved set of plans. Changes include removing two modules from the roof-layout and revising single line diagram. Note: Permit is paid under PCIS#16041-10000-32532	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60655	19041-10000-08035	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM	04/22/2021 12:00:00 AM		Permit Finaled	04/27/2022 12:00:00 AM	ADDRESS	34.21499	-118.4422	NOTE: PERMIT FEES ARE $0 DUE TO AB 1414PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 3960 MODULES (Q-PEAK 395), 2040 OPTIMIZERS (P850 ) AND 10 INVERTERS ( SE 99.9K). SYSTEM SIZE IS 1000KWac AND 1564.2KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60656	15041-10000-05286	1413 E 20TH ST	90011	9	120A211   326	5129005024	[Q]CM-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.02162	-118.24853	TI TO AN EXISTING COMMERCIAL SINGLE STORY BUILDING.  REPLACEMENT OF EXISTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 11136.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60657	13041-10001-28822	1339 N OGDEN DR	90046	4	147B177  1339	5551028008	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			Reviewed by Supervisor	10/21/2013 12:00:00 AM	ADDRESS	34.09553	-118.35939	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS UNGROUNDED SYSTEM. SYSTEM SIZE: 6.75 kW.(27) TRINA SOLAR # TSM-250(1) POWER-ONE # AURORA PVI-6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60658	13041-10000-02730	6515 W SUNSET BLVD	90028	13	147A187   104	5547017037	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	07/18/2013 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.09815	-118.33161	TENANT IMPROVEMENT TO EXISTING 4 STORY BUIIDING.  NO CHANGE OF USE OR OCCUPANCY.  EXTERIOR REPAINT & REPAIR STUCCO.  REPAIR CANOPY WITH SOME NEW STRUCTURE. NEW CORRIDOR, BREAK ROOM AND REMODEL RESTOOMS.  NEW LOBBY GLASS WALL TO GARAGE AND STORE FRONT WORK. ** FULLY SPRINKLERED BUILDING **	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60659	10041-10001-01068	3435 W WILSHIRE BLVD 152	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM			PC Approved	01/22/2010 12:00:00 AM	ADDRESS	34.06194	-118.29866	Changes to previously approved plans.  Change includes addition of new water heater.  P/C is for Power only :: T. I work in office area of unit 152. This P/C is only title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60660	18041-20000-24216	5766 W ADAMS BLVD	90016	10	123B173   983	5048008031	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.03223	-118.36931	Plan check for Title 24 energy only in existing space T.I. Total area: 1452 sq ft. B#18016-20000-12527	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60661	16041-10000-09821	14006 W RIVERSIDE DR #246	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM			PC Info Complete	04/13/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	NEW TI IN EXISTING RETAIL . PC FOR ENERGY ONLY. TOTAL AREA 542 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60662	19041-10000-49651	6222 W WILSHIRE BLVD	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	03/02/2020 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.06309	-118.36418	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1610 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60663	13041-10000-34012	8420 W MELROSE PL	90069	5	141B173   503	5528017036	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.08348	-118.3741	PLAN CHECK FOR T24 PART 6 ENERGY ONLY; RETAIL TENANT IMPROVEMENT, SCOPE OF WORK < 400A. SCOPE OF LIGHTING WORK IS APPROX. 2686 SF (INDOOR) AND 1389 SF (OUTDOOR) .  EMERGENCY LIGHTING IS ALSO IN SCOPE OF WORK. PERMIT UNDER 14041-20000-04136.NOTE:  APPLICANT NOW DECIDES TO GET PLAN CHECK FOR ENERGY ONLY INSTEAD OF POWER & ENERGY, AS INITIALLY REQUESTED. ][]  PLAN CHECK FOR POWER AND ENERGY PER APPLICANTS REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60664	17041-10000-21970	888 S FIGUEROA ST #620	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.0465	-118.26225	Title 24 plan check.  T.I. to existing office suite 620.  One new subpanel with lighting and receptacles.  Total area = 1,293 sq. ft.       Building permit #17016-10000-13718	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60665	11041-10000-17358	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Public Safety Only			08/16/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.03393	-118.22985	new fire warning system  for apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60666	14041-10000-29315	1619 N GOWER ST	90028	13	148-5A189 227	5546027013	C4-2D	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.1004	-118.32258	Full plan check for power and energy new car retail faclity including office building and car wash.  Office building 1532 sq ft car wash building  874 sq ft, parking lot 13426 sq ft. Service size 400 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60667	14041-10000-08957	2011 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	PIN	34.06587468	-118.19737837	RE-FEEDING EXISTING LIFE SAFETY AND STANDBY DISCTRIBUTION OF SOTO STREET BUILDING LOCATED AT 2001 N SOTO ST FROM EXISTING GENERATOR AT SOTO ST TWO BUILDING. PLAN CHECK PER APPLICANT REQUEST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60668	18041-20002-26134	1800 N WINONA BLVD	90027	13	150A195   249	5544012044	R3-1	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.10377	-118.30182	"Revision to approved set of plans.   Reduction in system size - permit work description revised to:""PV2.  Install 57.96 kW DC / 51.38 kW CEC-AC roof mounted grid tied PV system.  (168) modules with (4) 10 kW rated string inverters.""(((Plan check for a PV2 roof-mounted PV system. System size is 71.76 kWdc/63.61 kWac-CEC and consists of (5) 12 kWac rated inverters, (1) load center, and (208) modules.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60669	17041-10000-07536	21608 W VENTURA BLVD STE. 21608	91364	3	171B105    56	2168023067	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.16805	-118.60008	PC FOR NAIL SALON. NEW LIGHTING. PC FOR T24 ENERGY ONLY. REFER TO CEIS CASE # 628416. INVESTIGATION DUE UNDER THIS PERMIT AND ORDER TO COMPLY. PERMIT WILL EXPIRE WITHIN 30 DAYS OF ISSUANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60670	10041-10000-23742	3580 W WILSHIRE BLVD # 160	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.06156	-118.3028	REMODELING OF OFFICE SPACES;PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60671	11041-20000-17110	6100 W WILSHIRE BLVD	90048	5	135B177   521	5088002046	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/12/2011 12:00:00 AM	ADDRESS	34.06282	-118.36187	energy plan check suite 520 existing permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60672	13041-10000-34428	3448 W FERNCROFT ROAD	90039	13	153A207   218	5437022009	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM			Not Ready to Issue	02/20/2014 12:00:00 AM	ADDRESS	34.11319	-118.26351	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STD PLAN. SYSTEM SIZE : 3.65 KW .(17) SHARP PV ND 250QCS(17) ENPHASE M215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60673	19041-20000-03117	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	03/11/2019 12:00:00 AM	ADDRESS	34.04342	-118.25478	Plan check only for significant redesign to plans for permit issued under 14041-10000-27169.  Supplemental plan check. Conversion from office space to 2 floors retail and (6) live/work units.  (E) 2000A 240/120V 3ph-4w service with new distribution and loads throughout.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60674	12041-20000-21665	4647 N AVENUE 41	90065	14	160-5A217  88	5683012004	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.13496	-118.23196	New rooftop mounted photovoltaic system for an existing single family residence.  System uses transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60675	14041-10000-06018	529 S BROADWAY	90013	14	129A211   103	5149033007	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.04748	-118.25149	INSTALLATION OF A NEW FIREALARM SYSTEM. FULLY SPRINKLERED. 4 STORIES. 2 PANELS AND 106 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60676	19041-10001-32017	110 E 9TH ST LEVEL 8	90015	14	126A209    24	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REMOVAL OF FIXTURES, UPATING T24 AND INSTALLATIONG OF ADDITIONAL RECEPTACLES ADDRESS CHANGED FROM 110 W 9TH ST TO 110 E 9TH ST DUE TO DEPARTMENT ERROR ON THE APPROVED SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60677	15041-20000-26727	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			Reviewed by Supervisor	08/25/2015 12:00:00 AM	ADDRESS	34.09676	-118.29487	Plan check for power only.  Service upgrade from 800 A to 4,000 A to accomidate new chiller system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60678	15041-10000-30051	921 S CROCKER ST #C-16	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	PC for energy only, TI to an existing commercial bldg (retail store). The scope of work includes: new lighting new receptacles. SqFt = 1570.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60679	16041-20000-24569	18127 W TOPHAM ST	91335	3	177B125  1041	2124015047	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Expired	08/21/2018 12:00:00 AM	ADDRESS	34.18074	-118.52832	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (15) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60680	18041-10000-05751	1016 N SWARTHMORE AVE Suite #-5-101	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.04756	-118.52543	PC for power and energy for first time retail tenant. Installing three new panels, 30kVA XFRM, lights, receptacles and equipment. Total area 488.16sqft. B# 18016-10000-04755.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60681	17041-10001-15537	1111 S BROADWAY	90015	14	126A209   139	5139019035	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.03943	-118.25948	PC only, Delta 9 changes to an approved set. Relocating restaurants loads on MSB from one section to another for CT metering. E0-003 Changing the rating of MSB to 4000A with preapproved 4000A service. E0-003 Re-arranging fire-pump and sum-pump room equipment location. E1.200NAdding GFI's receptacles to genitor closetOriginal Plan check: ((PC FOR POWER AND ENERGY. CORE AND SHELL OF AN EXISTING BUILDING WITH PROVISION FOR FUTURE TENNATS. SCOPE OF THE PROJECT INCLUDES  0-5 LEVELS. SERVICE SIZE 5000 AMP, TOTAL AREA 19926 SQ FT.B # 16016-10000-19257	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60682	19041-10000-52824	4723 S NORMANDIE AVE	90037	8	111B193   761	5016020006	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2322.00	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	12/04/2020 12:00:00 AM		Permit Finaled	06/23/2022 12:00:00 AM	ADDRESS	34.00027	-118.30041	FULL PLAN FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A NEW 1200A 120/208V, 3PH 4 WIRE SERVICE. MAIN SERVICE SUB FEEDS TENANT AND HOUSE PANELS. NEW LIGHTING AND CIRCUITS. TOTAL INDOOR SQ. FT. 11114 AND OUTDOOR 3489 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60683	17041-10001-17273	3521 S 7TH AVE	90018	10	120B189  1089	5044016026	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.02347	-118.3249	Expedite fees only.  Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 6.6 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60684	19041-10000-45429	5903 N FIGUEROA ST	90042	1	151-5A229  62	5492013020	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.20	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	01/31/2020 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.11084	-118.19074	TI  FIRST TIME TENANT. FULL PLAN CHECK FOR 2 NEW PANELS FROM TWO EXISTING SERVICES AND TITLE 24. SQ FOOTAGE: 3215 SQ FEET (INDOOR LIGHTING) AND 223 SQ FEET (OUTDOOR LIGHTING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60685	11041-10000-06945	107 E 6TH ST UNIT #3	90013	14	127-5A211  38	5148020007	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			PC Info Complete	04/07/2011 12:00:00 AM	PIN	34.04515004	-118.24956841	TI IN AN EXISTING COMMERCIAL AREA IN UNIT #3 ON THE 1ST FLOOR.  PLAN CHECK IS FOR T-24 ENERGY ONLY.   ====>>>>>>INSPECTOR: PLEASE VERIFY THAT THERE IS NO EMERGENCY GENERATOR IN THE BUILDING FOR THE EMERGENCY LIGHTS AND EXIT SIGNS ARE ALL OF A UNIT EQUIPMENT TYPE. IF EMERGENCY GENERATOR IS AVAILABLE PLEASE SEND THE CLIENT BACK TO PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60686	14041-10001-21987	8901 S METTLER ST	90003	9	096A207   231	6041025008	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	33.95544	-118.26663	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 1.785 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(7) MODULES: KYOCERA KD 255GX(1) INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60687	18041-10000-47799	3030 N ANDRITA ST	90065	13	154-5A213 199	5458008013	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM			PC Approved	01/30/2019 12:00:00 AM	ADDRESS	34.11608	-118.24584	PLAN CHECK FOR TITLE 24 T.I OF Existing Office WITH 6606 SQFT.**Plan check withdrawal per applicant Tom Majich request.Tom Majich, tm@arroyohill.comT 626 833 0210	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60688	16041-10000-03081	5900 W CENTER DR 1-327	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	33.97559	-118.38853	6outdoor sign lights: ALTITUDE, RESIDENT PARKING, LEASING. PC for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60689	18041-30000-07167	2029 S CENTURY PARK EAST 25st Floor-RR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing space men and women restroom on 25st floor. Total area: 410 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60690	14041-10010-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			PC Approved	08/18/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	Revision to approved set noted on delta-29: add note for the trip setting, rearranging tenants space on the single line diagram. Thsi is plan check only, no permit is needed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60691	17041-10000-20050	753 N ORANGE DR	90038	5	141B181   333	5525007027	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.08494	-118.34172	Installation of new roof mounted solar PC system with battery back up on eixsitng single family dwelling.  Central inverter with 2 Tesla AC Powerwall 5.8 kVA / 13 kWH batteries.  Total system size = 3 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60692	13041-10000-12866	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.14441	-118.39252	"PC FOR POWER. NEW EQMT AT CBS CENTRAL PLANT #4. MEDIUM VOLTAGE installation.a. install (2) 600A 2400V bussed switches in the basement electrical room (1) 600A switch for central plant; (1) 600A switch for future 1500KVA transformer.B. Tap off existing bus in ""MSA"" to feed new 2400V switches.C install (N) 750KVA NEMA 3r transformer in teh central plant fed from the (N) 600A 2400V swtich.D. install (N) 1000A 480V NEMA 3r switchboard in teh central plat fed from the (N) 1000KVA transformerE. install (N) VFD for CHWP-1, CHWP-2, CWP-1, CWP-2, CT-1F. install underground feeder from the switchbaord to the equipmentG. install new light fixtures and service receptacles for central plant.H. light fixtures and service receptacles fed from 120V panel in teh (N) switchboard."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60693	15041-10000-36888	5816 S 2ND AVE	90043	8	108B189  1450	4005025010	RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	33.98855	-118.31948	PV1, ROOF MOUNTED SYSTEM, TOTAL SIZE 3KW. (10) MODULES AND (1) INVERTER. (10) KYOCERA #KU2656ZPA(1) ABB# PV1-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60694	14041-20000-24062	19612 W ENADIA WAY	91335	3	183B117   175	2130004004	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.20001	-118.56046	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(26) SolarEdge P300 power optimizers(26) Trina Solar TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60695	18041-20000-21186	1223 N EDGEMONT ST	90029	13	144B197   172	5540011009	R3-1XL	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	11/12/2020 12:00:00 AM	ADDRESS	34.09407	-118.29636	Plan check for power and energy. Project site is a new 2-story, 13-unit apartment building with mezzanine over a basement parking garage. Work include a 800-amp service and a total lighting area of 13,349 sq. ft.Note: Building application has been generated under 17010-20000-01752	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60696	16041-20001-40682	15816 W LEADWELL ST	91406	6	186B141   869	2206037102	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	PIN	34.20365596	-118.47775758	EXPEDITE PER APPLICANT REQUEST.Plan check for the installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP.10.08kW ungrounded system. (28) 360W ac modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60697	10041-30000-07916	435 S MOLINO ST	90013	14	127-5A215 380	5163021027	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	06/15/2010 12:00:00 AM	ADDRESS	34.04193	-118.23409	Reconneting existing 400 AMP service with 600 amp buss and panel to feed one AC unit of 19.2 amp. All other existing loads will be removed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60698	13041-20000-00053	18880 W PASADERO DR	91356	3	165B121   348	2177025017	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.14852	-118.54547	New 8.5kw rooftop mounted photovoltaic system for an existing single family dwelling.  System uses Enphase microinverters.  Plan check is only for the PV System, Not the service upgrade. 200A service upgrade has been added to permit fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60699	16041-10001-35261	20255 W GAULT ST	91306	3	183B113   164	2135001028	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.19935	-118.57507	Expedite fees only.            Addition of 17 new solar panels, 17 new microinverters, and 1 new AC load center to existing solar system.  Rooftop solar system on existing single family dwelling.  Total size = 10.92 kW (4.25 kWac new)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60700	10041-20000-22654	16846 W SAN FERNANDO MISSION BLVD	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	03/10/2011 12:00:00 AM		Permit Finaled	06/02/2011 12:00:00 AM	ADDRESS	34.27101	-118.49951	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR RETAIL TI (UNLEASHED)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60701	13041-10000-04195	19081 W KILLOCH WAY	91326	12	219B121   338	2820011012	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.2936	-118.54883	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. TOTAL SIZE 3.67KW. USING 17 PANELS REC 245 PE. USING ENPHASE MICROINVERTER M215-60-2LL-S22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60702	14041-10000-33630	5880 W CENTINELA AVE	90045	11	102B169    61	4103005002	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	33.9764	-118.38423	plan check for energy only. ti.exterior remodeling of auto dealership w/new service office addition and interior remodeling of showroom/customer areas / office. total area 7343 sq ft(indoor) and 3672 sq ft(outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60703	15041-20000-36021	6040 N CANOGA AVE	91367	3	177B105   120	2149005052	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.18037	-118.59721	Plan check for Title 24 for existing space T.I. Total area: 6,766 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60704	15041-20000-31800	7002 N OWENSMOUTH AVE	91303	3	183B105   664	2138008012	P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Issued	10/07/2015 12:00:00 AM	ADDRESS	34.19758	-118.60139	Plan check for a PV2 roof-mounted PV system. System size is 13.5 kWac and consists of (54) modules, (54) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60705	15041-10000-26630	3959 W WILSHIRE BLVD B5	90010	10	132B193    31	5504027020	C4-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.06186	-118.31337	Energy plan check for a retail (coffee shop) T.I ; Scope includes new lighting and receptacles, Total area is 800-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60706	12041-20000-27187	221 S FIGUEROA ST 120	90012	9	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	34.05628	-118.25373	Plan check for energy only. Low rise commercial building. 2965 sqft indoor. SUITE 120.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60707	11041-10000-26988	11122 W MAGNOLIA BLVD	91601	4	171B173   623	2353005010	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.16471	-118.37329	TENANT IMPROVEMENT AND CHANGE OF USE FROM AUTO BODY REPAIR TO RESTAURANT WITH OUTSIDE DINING AREA.  NO ALCOHOLIC BEVERAGES WILL BE SERVED IN THE PREMISES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60708	16041-10000-39052	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.16603	-118.52861	Plan check for power and Title 24.  T.I. to existing ambulatory surgical center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60709	17041-20000-24512	15821 W VENTURA BLVD STE 420	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	PLANCHECK FOR T24 ENERGY. TENENT IMPROVEMENT TO COMBINE SUITE 420 & 415 TO CREATE ONE TENANT. HIGH RISE/ 10976 SQFTbuilding permit # 17016-10000-17382	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60710	13041-10000-35759	430 S BROADWAY	90013	14	129A211    57	5149024008	[Q]C4-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.04864	-118.24991	"FA for live work,, existing 6 story commercial building converterd to 58 join living work quarters with ground floor commercial use.  not hirise per applicant. plan checker to verify.BUILDING PERMIT 13016-10000-06356 - MODIFICATION OF BUILDING ORDINANCE HAS BEEN ACQUIRED TO MAINATAIN THE CURRENT NON-HIGHRISE BUILDING STATUS.""COMPLY WITH DEPARTMENT ORDER effective date 07/28/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60711	13041-20001-35468	2031 W PANAMINT DR	90065	1	151-5A219 167	5462017023	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.10956	-118.22529	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 27 MODULES TRANSFORMERLESS INVERTER NONSTANDARD PLAN.  3 STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60712	13041-10006-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	"CHANGES TO AN APPROVED SET OF PLANS FOR A SCHOOL. ALL CHANGES ARE CLOUDED UNDER DELTA 26A. CHANGES INCLUDE ADDING A SHUNT TRIP FOR ELEVATOR, REVISING SHORT CIRCUIT CURRENT FOR PANEL R1, AND REVISING ELEVATIONS FOR DISTRIBUTION BOARD ""MSB"" & ""MS2"", REVISING PANEL SCHEDULES. NOTE: PERMIT HAS BEEN PULLED UNDER THE MASTER APPLICATION."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60713	12041-10000-26200	9228 N TUJUNGA AVE	91352	6	198B169   116	2538010002	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Info Complete	10/28/2014 12:00:00 AM	ADDRESS	34.2366	-118.38036	EDIT: SUBMITTED ON FEB. 4, 2013.  CUSTOMER BROUGHT IN CHECK MADE OUT FOR FEE CALC DONE OCT. 12, 2012, FEES MAY NEED TO BE ADJUSTED DURING PLAN CHECK.PLAN CHECK POWER. NEW ELECTRICAL SYSTEM MEDIUM VOLTAGE FOR MACHINES. EXISTING AUTO DISMANTLING FACILITY. SITE LOCATED IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60714	19041-20000-04609	10838 W VIA VERONA	90077	5	147B145   119	4377037016	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Issued	02/07/2019 12:00:00 AM	ADDRESS	34.09892	-118.45909	Plan check for PV roof mounted system, system size: 10.08 KW with 28 P V Moduld and 28 microinverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60715	13041-20000-08659	13130 W BURBANK BLVD	91401	4	174B157  1137	2345005028	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Info Complete	04/04/2013 12:00:00 AM	ADDRESS	34.17191	-118.41936	REPLACE EXISTING GENERATOR EMERGENCY LIGHTING SYSTEM WITH UNIT EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60716	14041-20001-26290	505 N HAYWORTH AVE	90048	5	141B177  1154	5527019011	R3-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.08027	-118.36291	[3/11/2015]  Supplemental application for changes to approved set.  Addition of one delta -> wye transformer for elevator.  Changing conductors from copper to aluminum.*****Previous Work Description*****NEW 2-STORY 5 UNIT APARTMENT WITH SUBTERRANEAN BASEMENT PARKING GARAGE [FIRE SPRINKLERS REQ'D THROUGH-OUT].  800A SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60717	18041-10000-38762	12665 W VILLAGE LANE	90094	11	102B161  1257	4211034106	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/10/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	33.97786	-118.41484	PLAN CHECK FOR TITLE 24 ONLY FOR - DEMO/CONVERT 3 EXISTING PARKING STALLS TO CONSTRUCT NEW PARCEL AND PACKAGE ROOMS TO BE USED BY RESIDENTS FOR PACKAGE DELIVERY - TOTAL AFFECTED AREA = 371 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60718	17041-10000-21043	9017 N RESEDA BLVD	91324	12	195B125   116	2770004009	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Issued	06/22/2017 12:00:00 AM	ADDRESS	34.2343	-118.53628	Title 24 plan check.  Remove metal halide fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60719	11041-20000-13360	8430 N VAN NUYS BLVD	91402	6	192B149   341	2638022061	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.22417	-118.44858	EPC IS FOR POWER & ENERGY. CHG OF USE FROM RETAIL TO WEDDING CHAPEL WITH RETAIL SALES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60720	10041-10000-10524	19900 W VENTURA BLVD #200	91364	3	174B113   424	2164001035	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.17204	-118.56636	Change of use from office to Dental office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60721	15041-20000-29729	8043 N VARNA AVE	91402	6	189B157   235	2301005006	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.21689	-118.42491	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60722	16041-10001-33558	11601 W WILSHIRE BLVD 7TH FLR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR REDUCE SCOPE OF WORK. ONE OF THE ROOMS NOT SUBDIVIDING. PC FOR DELTA 1 REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60723	16041-10000-08818	501 S ANDERSON ST	90033	14	126A219    25	5171010012	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.04093	-118.22502	NEW EXTERIOR LIGHTING; INSIDE LIGHTING CHANGES DOES NOT WARRANT TITLE 24 PLAN CHK FOR EXTERIOR LIGHTING TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60724	15041-10000-19548	8221 W SUNSET BLVD	90069	4	147B173   195	5555030010	R4-1D	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM			Reviewed by Supervisor	07/14/2015 12:00:00 AM	PIN	34.0982535	-118.3684526	REMODEL TO AN EXISTING HOTEL KITCHEN.  NEWLY CONNECTED LOAD >400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.******THE SQ FT AREA SHOULD BE ADDED IN THE FINAL FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60725	14041-20000-14318	7544 N LILLA PL	91304	12	186B089   133	2027035022	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.20897	-118.64522	(($0 permit fee due to senate bill 1222 from 2012))PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 11kW(1) Power-One #Aurora PVI-5000-OUTD-US-Z-A transformerless inverter(1) Power-One #Aurora PVI-6000-OUTD-US-Z-A transformerless inverter(55) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60726	18041-20000-43737	3397 N BARHAM BLVD	90068	4	159B181   187	5579007022	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	01/11/2023 12:00:00 AM	ADDRESS	34.1333	-118.34402	PV3.  Install 4.2 kW roof mounted grid tied PV system.  (14) modules with 5 kW rated string inverter.  System 1 of 2 - other system is a 4.5 kW roof mounted grid tied PV system interconnecting at a separate subpanel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60727	17041-10000-05914	1830 N BRONSON AVE 1-81	90028	13	150A191   264	5586028026	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.10433	-118.31784	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS FOR AN OFFICE FOR A SCIENTOLOGY BUILDING. A OCCUPANT LOAD < 100. TOTAL AFFECTED AREA IS 7596 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60728	17041-10000-12002	5722 W JEFFERSON BLVD	90016	10	120B173   311	5047018002	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.02588	-118.36994	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 51950 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60729	12041-10000-17440	608 E MANCHESTER AVE	90002	9	097-5A207 321	6042001032	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	PIN	33.95984394	-118.2645255	Plan check for energy and emergency lighting. 1550 sqft. Take out pizza restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60730	17041-10000-14388	2421 E 16TH ST	90021	14	118-5A217  86	5168008003	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.01978	-118.2294	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new led ones. Area: 19850 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60731	19041-20001-25135	20135 W JUBILEE WAY pv1	91326	12	213B113   412	2701087040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	34.28259	-118.57288	expeditepv1install roof mounted pv system sized 11KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60732	18041-10000-00723	15030 W VENTURA BLVD 1-A	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.15272	-118.46063	TI OF TWO EXISTING RESTAURANTS TO CREATE ONE 2135 SF TENANT SPACE TO BE USED AS A 'STARBUCKS'. INSTALL (3) NEW PANELS ON (2) EXISTING 400A SERVICE (DIFFERENT VOLTAGE CLASS), TOTAL NEW LOAD > 200A[B# 18016-10000-00419]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60733	16041-20000-03123	11400 W OLYMPIC BLVD	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.03666	-118.44346	Plan check for energy only. Replace (13) existing flourescent 2x2 fixtures with new LED 2x2 fixtures. Add new receptacles. 713sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60734	14041-20001-09217	5091 N CALATRANA DR	91364	3	171B105  1176	2168014064	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.1612	-118.60255	EXPEDITE PER APPLICANT REQUEST(((PV1Install roof-mounted solar array on SFD, interconnect with main panel.(28) PV Modules - Canadian Solar #CS6P-250PX(1) Transformless inverter - SolarEdge #SE6000A-US-ZB-U)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60735	15041-10000-05313	4063 S ADAIR ST	90011	9	115-5A205 407	5113023025	[Q]R4-1	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.00933	-118.26938	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 12132 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60736	19041-20000-32641	12653 W OSBORNE ST BLDG GSA	91331	7	204B161     2	2536017906	OS-1VL-CUGU, PF-1VL-O-CUGU, [Q]MR2-1VL-O-CUGU, [T][Q]MR2-1VL-O-CUGU	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.25491	-118.40888	PV3.  Installation of 58.56 kW DC / 52.07 kW AC roof mounted grid tied PV system.  (183) modules and 2 string inverters.  $0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60737	15041-20000-38684	3465 W 6TH ST #50	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.06373	-118.29761	Change of use from music studio to restaurant. Plan check for energy only. Adding new lighting including emergency. Total sqft. 1,581.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60738	10041-20001-09117	6253 W HOLLYWOOD BLVD #203	90028	13	148-5A189 343	5546030035	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	10/20/2010 12:00:00 AM	ADDRESS	34.10179	-118.32624	First time tenant for office space #203 in an adpative reuse high rise building. Plan check for power. T-24 Energy was checked under #10041-20000-09117	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60739	15041-10000-09961	5200 W 104TH ST	90045	11	090B173   326	4129035017	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	33.94163	-118.3704	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60740	17041-10000-01861	1755 N ARGYLE AVE	90028	13	148-5A189   5	5546030029	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.1035	-118.32546	NEW FA SYSTEM FOR NEW BUILDING. 17 STORY HIGH RISE WITH 1 LEVEL OF SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60741	18041-20000-18728	941 W 37TH PL	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.01943	-118.2897	Private street and landscape lighting.  New subpanels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60742	13041-10001-29539	3115 N DONA MARTA DR	91604	2	156B173    46	2380023006	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.12766	-118.37798	Expedited RSES plan check per applicant request. ((((PV1.  Install 9 kW DC roof-mounted solar array, interconnect with main service panel. Inverter: Fronius IG Plus V 7.5.  16 modules: Trina Solar TSM-250PA05.18))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60743	19041-20000-17500	14609 W DEL PLAYA ST LOT 4-pv1	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.24792	-118.45074	pv1install roof mounted pv system sized 3.02KW AC interconnected with msp.(9) acm rated 335W each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60744	12041-10000-18854	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	09/25/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	Change to lighting and receptacles to an existing Walk-up restaurant.  Load is less tha 200A, and occupany load is less than 99 people per applicant.  UNIT #742	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60745	18041-20001-17288	17501 W RAYEN ST	91325	12	195B129   200	2768026009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM			PC Approved	05/30/2018 12:00:00 AM	ADDRESS	34.23232	-118.51605	Expedite per applicant requestPlan check for PV roof mounted system, system size: 19.55kWac with 85 modules and 85 microinverters connectyed to MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60746	15041-20002-34238	209 S LORING AVE	90024	5	141B153   306	4359001028	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.07848	-118.43732	06-08-2018 Changes to an approved set of plans. Changes include addition of 200A meter For EV Chargers (under separate permit 18041-20000-16564), modify loads and breakers on DSA, addition of panel L2, P3, UT2, UT1. Plans redesigned to reflect as-built conditions. All changes has been clouded and marked as Delta 3.*****Previous Work Description*****Plan check for 800A service  for new single family dwelling New three story SFD with attached garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60747	17041-10000-23024	3250 W OLYMPIC BLVD ste 102	90006	10	129B193   288	5080009008	[Q]C2-2D	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.05244	-118.30766	PC for T24 for new lighting. Total affected area is 1230 sqft. Building# 17016-10000-3250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60748	15041-20000-40464	21215 W BURBANK BLVD #620-BLDG E	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.17353	-118.59268	T-24. PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (AETNA, OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING AND THREE NEW PANELS. TOTAL AREA IS 13149 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60749	16041-10000-13363	2049 S CENTURY PARK EAST 8th-restrooms	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR T24 ONLY. T.I. IN MEN AND WOMEN RESROOMS, CENTURY PLAZA TOWERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60750	14041-10000-07497	12898 N BRADLEY AVE UNIT A	91342	7	222B149   561	2506010008	M1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.30437	-118.45823	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 3000 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60751	16041-20000-08974	7800 N VENTURA CANYON AVE	91402	6	189B157   794	2301012099	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.21204	-118.42858	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (21) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60752	12041-10000-13135	16904 W DEVONSHIRE ST	91344	12	204B133   221	2685002041	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	09/07/2012 12:00:00 AM	ADDRESS	34.25731	-118.50043	T.I. to an existing restaurant with an occupancy load of 120 people, per applicant.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60753	17041-10000-23478	13060 W RELIANCE ST	91331	6	195B161   274	2627018007	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.23344	-118.41733	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM CONSIST OF (24) M250 MICROINVERTERS WITH MODULES. TOTAL SYSTEM SIZE =  6.0KVA	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60754	11041-10000-27304	4241 N FORMAN AVE	91602	4	165B181   442	2424023027	RE11-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	03/20/2012 12:00:00 AM	ADDRESS	34.14717	-118.35285	New 10.34KW roof mounted photovoltaic system for single family dwelling.  New 200 amp main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60755	19041-10000-04858	1123 N VINE ST	90038	13	144B185   639	5533007025	C2-1D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.09139	-118.32683	ENERGY PLAN CHECK FOR A CHANGE OF USE FROM OFFICE TO MASSAGE PARLOR. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 957-SQ FT. DESIGN BUILD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60756	17041-10000-31492	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	PC FOR EXTRIOR LIGHTS TO ILLIMINATE NEW EQUIPMENT.  TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 3132 SQ.FT. SCOPE INCLUDES NEW LIGHT CIRCUIT AND 11.5 HP COMPACTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60757	14041-10000-08395	201 W WASHINGTON BLVD	90015	14	123A207    51	5126027007	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.03222	-118.26683	FULL PLAN CHECK POWER AND ENERGY FOR A NEW MCDONALD BUILDING. TOTAL AREA(INDOOR+ OUTDOOR) 62986 SQ FT. (BUILDING #S 14014-10000-00776 & 14010-10000-00526)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60758	08041-10001-23810	13031 W JEFFERSON BLVD	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM			PC Approved	11/16/2011 12:00:00 AM	ADDRESS	33.97451	-118.42531	The 4160V substation is existing to remain.  Demolish all electrical work except the service and install all new electrical equipment for a 2-story commercial building.  Plan Check for Power and energy. (2005 Code)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60759	09041-10001-14182	4810 W SUNSET BLVD	90027	13	147B197   737	5543017018	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM			PC Approved	02/02/2010 12:00:00 AM	ADDRESS	34.09792	-118.29436	REVISED DRAWINGS FOR THE LIGHTING PLANS-APPROVED SET OF PLANS SHOW OCCUPANCY SENSORS TO BE USED THROUGHOUT THE BUILDING. INSTEAD, THE EXISTING ENERGY MANAGEMENT SYSTEM WILL BE USED FOR SHUT-OFF CONTROL OF THE BUILDING LIGHTING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60760	14041-20000-10275	19121 W LIGGETT ST	91324	12	198B121   273	2762019006	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.24047	-118.54997	Roof mounted PV system with Optimizers and  transformerless inverters.  System size 8.5 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60761	13041-20002-07436	6374 W SUNSET BLVD SUITE B	90028	13	147A187   590	5546015043	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.09768	-118.32839	"Modification to previously approved set of plans.  Change of a light fixture type, relocation of equipment, removal of EF-2, no new circuits added.  PLAN CHECK ONLY for ""DELTA 2"".              <<<Full plan check for power and energy for first time tenant sushi restaurant. 3529 sqrft. 250A load.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60762	16041-20001-22020	8891 W COLLINGWOOD DR	90069	4	147B169   822	5560038004	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.09599	-118.38461	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (3) inverters, (61) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60763	13041-10000-13327	5865 S CAMPUS CENTER DR BLDG 14	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM	06/20/2013 12:00:00 AM		Permit Finaled	08/16/2013 12:00:00 AM	ADDRESS	33.97808	-118.40726	Plan check power and energy for robotics facility with manufacturing and testing area. No classified area. Existing Building #14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60764	14041-10000-33466	12243 W BRANFORD ST	91331	7	201B165    28	2537015063	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	PIN	34.25127853	-118.40048138	Title 24 plan check only.  Total area = 4512 sq. ft.Remove HID lighting and replace with new LED fixtures (modification in place)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60765	14041-20000-30752	510 S NORMANDIE AVE 1-40	90020	10	135B197   812	5502018022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			11/05/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	34.06494	-118.30016	PV2Install roof-mounted solar array on Apartment building. Interconnect with 200A service (?).System size: 11.4kW. Grounded system.44 305W pv modules across 4 strings (11+11+11+11).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60766	17041-10000-22111	9046 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.23442	-118.55336	PLAN CHECK FOR T24 ONLY FOR TI (INTERIOR TI FOR CHANGE FROM EXISTING RESTAURANT TO BAKERY. TOTAL AFFECTED AREA = 3925SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60767	15041-20002-21587	5327 N HERMITAGE AVE	91607	2	171B165   215	2347025013	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			06/28/2017 12:00:00 AM			PC Approved	06/28/2017 12:00:00 AM	ADDRESS	34.16757	-118.40046	6.28.2017 - Plan check for modifications to approved set. Delta 2 clouded changes only. Reducing unit feeder sizes. Reducing water heater conductor to #14AWG. Reducing some dwelling unit branch circuits in each unit panel to 15A/#14AWG.=======5/16/17changes to an approved set of plans.  changes noted delta 1.  changes include new distribution board, panels and ocpd for each unit.(((((Plan check for power and energy. Project scope is a new 4-story, 42-unit apartment building. Work includes a new 1600-amp service, (54) panels, and associated loads. Fire alarm variance has been filed.Building permit found under application number 15042-20000-13720.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60768	10041-10000-11344	500 S CENTRAL AVE	90013	14	126A215    61	5147014005	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	04/25/2012 12:00:00 AM	ADDRESS	34.04092	-118.23969	TI IN AN EXISTING COMMERCIAL AREA (OFFICE, MACHINE ROOM & ELEVATOR LOBBY).  PLAN CHECK IS FOR T-24 ENERGY CALCS. PERMIT IS FOR A NEW PANEL AND NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60769	17041-30000-11677	1039 S HOBART BLVD	90006	10	129B193   505	5080017107	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	34.05145	-118.30541	Plan check for Fire alarm system for 28 units appartment. Total fire alarm devices: 75 and 1FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60770	16041-20000-44962	418 N NORTH FARING ROAD	90077	5	141B157    12	4358007015	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			Reviewed by Supervisor	01/25/2017 12:00:00 AM	ADDRESS	34.08616	-118.43257	Plan check for power. (N) One story guest accessory living quarter at southeast side of the property(Accessory Building#3) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60771	19041-20001-36732	5727 N CANOGA AVE BLDG 19	91367	3	174B105    28	2146031201	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM			PC Approved	10/14/2020 12:00:00 AM	ADDRESS	34.17529	-118.5978	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60772	17041-10001-17278	41 E OZONE AVE	90291	11	111B141   730	4286018026	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	33.99605	-118.48001	Expedite fees only.  Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  One Tesla DC Powerwall 5 kW 13.5 kWH battery and Solarcity Delta H 6 kWac inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60773	18041-10000-05017	1143 S BEVERLY DR	90035	5	132A167   122	4330026008	C2-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.0565	-118.39646	Plan check for Title 24 only in existing space Massage Parlor. Total area: 846 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60774	11041-10000-03253	4658 W MELROSE AVE	90004	13	141B193   584	5521007035	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Public Safety Only			02/18/2011 12:00:00 AM	02/18/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.08333	-118.30203	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60775	13041-10002-07308	16122 W MORRISON ST	91436	5	168B141   100	2260022005	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.16015	-118.48458	((changes to approved set of plans: removed jbox and changed location of inverters from west side of house to the northeast corner of house))PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING, TOTAL SYSTEM SIZE 6.86 KW. NEW LOAD CENTER MULTIPLE INVERTER TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. USING TOTAL OF 28 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60776	19041-10000-31824	13655 N SPROULE AVE	91342	7	228B149   498	2502011036	R1-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.32026	-118.45477	PV1 - NEW ROOF MOUNTED 8 KW (DC) PV SYSTEM WITH 28 PV MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60777	13041-10000-31471	7260 W HAWTHORN AVE 1-25	90046	4	147B181   443	5548010018	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.0996	-118.34834	FA FOR APARTMENT R-2/S-2 TYP V-A FULLY SPRINKLERED. 4 stories.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60778	13041-20002-32780	18497 W NORDHOFF ST	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.23566	-118.5358	pc for t24 energy only. permit already ussued under supplemental - 1. This is for plan check for t24 energy compliance for new lighting. existing tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60779	17041-10000-19866	1836 N GRAMERCY PL 1-28	90028	13	150A193   251	5544003046	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.10435	-118.31211	PLAN CHECK FOR POWER ONLY - SCOPE INCLUDES DISTRIBUTION BOARD  AND FEEDER FOR FOR 28 UNIT 3 STORY APPARTMENT. UNIT PANELS AND BRANCH CIRCUITS ARE UNDER DIFFERENT PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60780	13041-10000-09410	22273 W BUENAVENTURA ST	91364	3	168B101   623	2170002037	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.15561	-118.61232	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. MICROINVERTER SYSTEM PV1 SINGLE FAMILY DWELLING. TOTAL SIZE 3.45 KW. USING 16 PANELS. SINGLE STRING. STANDARD PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60781	12041-10000-27421	6009 W 76TH PL	90045	11	102B169   544	4106009003	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	33.97132	-118.38903	PV1 4.16KW ROOF-MOUNT ENPHASE MICROINVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60782	15041-10000-11813	450 S WESTERN AVE 2stFL #201	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	PC FOR ENERGY ONLY.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  TOTAL AREA 1200 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60783	10041-20000-01490	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM			PC Approved	01/27/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	T. I. work in candy apple store. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60784	15041-20001-39703	13650 W BURBANK BLVD	91401	4	174B157   611	2344001014	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.17196	-118.43072	Revisions made to approved set.  Inclusion of (E) lighting into lighting plan and change of panel location.  (((PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM (E) RETAIL TO (N) BEAUTY SALON.  866 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60785	18041-10000-41023	5480 N QUAKERTOWN AVE	91364	3	174B113   511	2166003019	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.16994	-118.56951	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60786	15041-10000-28674	1311 E 3RD ST	90033	14	127-5A219  62	5172010004	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM			Corrections Issued	08/31/2015 12:00:00 AM	ADDRESS	34.04497	-118.22616	Energy plan check for a studio; Scope include new light and receptacle outlets. Total area is 11613-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60787	15041-10000-13650	400 S HOPE ST 18th floor	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.05199	-118.25366	Energy plan check for an office T.I located in the 18th floor of a high rise building . Scope include installation of 2-new panel, (1) UPS system, new lighting and receptacles in a portion of a whole office area. total work area is 3240-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60788	15041-10000-27104	600 WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	"NEW ""OSTERIA"" RESTAURANT IN TERMINAL 6 OF LAX.NOTE: FIRST TENANT ON THE DISTRIBUTION PANEL.THERE ARE NOT ANY OTHER CONNECTED LOAD."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60789	14041-20001-02337	4640 N LANKERSHIM BLVD GRD FLR-LOBBY	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.15499	-118.36841	Changes from previously approved plans.  Add two new emergency inverter power supplies.  Plan check for energy only.Note: Permit is under a separate application.****T24 FOR EXISTING OFFICE BUILDING. RECONNECTING TO EXISTING CIRCUITS*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60790	18041-10000-24149	1030 N SWARTHMORE AVE #2-109 &-B1M-114	90272	11	129B125   838	4423016024	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	"PLAN CHECK FOR POWER AND ENERGY - First time Tenant improvement to retail space ""CHANEL"" within Pacific Palisades Village Shopping Center. TOTAL AFFECTED AREA = 979, TOTAL CONNECTED LOAD = 250A."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60791	12041-10000-22877	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM			PC Approved	09/25/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR T.I. FOR OFFICES ON 2ND FLOOR (SUITE #270) OF HIGH-RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60792	12041-10000-02051	2101 S SAWTELLE BLVD	90025	11	126B153   909	4260002029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM			Corrections Issued	08/07/2012 12:00:00 AM	ADDRESS	34.03929	-118.44248	T.I. to an existing restaurant.  Lighting changes.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60793	18041-10000-35493	555 W 5TH ST #3110	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER IN THE 31ST FLOOR. TOTAL SQ. FT. 1736.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60794	17041-10000-10222	1180 S BEVERLY DR #600	90035	5	132A167   177	4330031026	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.05581	-118.39554	Plan check for Title 24 only in existing space T.I. office space. Sapce # 600. Total area: 1,610 sq ftCOMPLY WITH DEPARTMENT ORDER effective date01/13/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60795	19041-30000-16386	601 S FIGUEROA ST Suite 3400	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is a tenant suite on the 34th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 11,985 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60796	18041-20000-29656	11755 W WILSHIRE BLVD 21st floor-RestRoom	90025	11	129B145   683	4265010192	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for Title 24 only in existing restroom high-rise building T.I. Total  area: 400 sq ft.B#18016-10000-13136	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60797	15041-10000-06004	555 W 189TH ST	90248	15	063B201   200	7339008030	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	33.86427	-118.28349	REPLACING HID LUMINAIRES IN AN EXISTING WAREHOUSE TO LED LUMINAUIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60798	15041-20000-42430	8415 N RESEDA BLVD #5,6,7,8	91324	12	192B125   409	2785018063	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Issued	12/16/2015 12:00:00 AM	ADDRESS	34.22319	-118.53631	TI, change of use from retail to Learning center. All electrical equipments are existing. PC for Energy only. Total area: 3,400 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60799	19041-20000-44853	3355 S OVERLAND AVE	90034	5	120B161   422	4254024024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	02/07/2023 12:00:00 AM	ADDRESS	34.02662	-118.41332	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. SCOPE OF WORK CONSISTS OF (1) FA PANEL AND (124) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60800	15041-10000-40773	1865 S LA BREA AVE	90019	10	126B181   962	5067014030	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.0408	-118.34755	PLAN CHECK FOR POWER AND ENERGY FOR PROPOSED NEW RESTAURANT WITH 600A SERVICE 5000SQRFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60801	18041-10000-15639	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	PC FOR T-24 ENERGY ONLY FOR TI  IN AN EXISTING COMMERCIAL PLACE. SCOPE INCLUDES NEW PANELS, LIGHTING AND RECEPTICAL. TOTAL AFFECTED AREA IS 11672 SQ.FT.B# 16016-10000-09906	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60802	18041-20000-20958	21300 W VICTORY BLVD Suites 770-780	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check for Title 24 only in existing in high rise building office T.I. Total area: 1835 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60803	15041-10000-20468	11766 W WILSHIRE BLVD STE 560	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.04804	-118.46227	TI, ADDING NEW LIGHTING AND CIRCUITS LESS THAN 400AMPS. PC FOR ENERGY ONLY. TOTAL SQ. FT. 2521	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60804	14041-20000-27162	12930 W WENTWORTH ST	91331	6	195B161   121	2628010019	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.23476	-118.41419	PV STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60805	11041-20000-18111	3800 N HOMER ST	90031	1	144A225   521	5207006900	[Q]OS-1XLD-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco, Lincoln Heights	YES	1994.00	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.08842	-118.20786	Plan check new transformer, feeder, panels, ckts supplying pharmacy building and lincoln church building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60806	19041-10000-45051	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR T24 ONLY, SCOPE OF WORK IS A NEW SIGN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60807	11041-20000-01592	8505 N CEDROS AVE 1-22	91402	7	192B149   170	2653016050	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.02	Electrical	Electrical	Apartment			01/26/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Closed	02/23/2011 12:00:00 AM	ADDRESS	34.22497	-118.4538	fire alarm apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60808	19041-10002-05103	1216 S BURNSIDE AVE	90019	10	129B181   180	5085015043	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.05276	-118.35301	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE REVISION OF 400 AMP MAIN BREAKER AND LOAD CENTER. ________________________________________PV1. New Solar system on existing residential roof-top. Total system size is 3.00KWdc / 2.673KWac. Note: Plan Check Only. Permit under original application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60809	09041-10003-06478	560 S MAIN ST	90013	14	127-5A211  38	5148020007	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM			PC Approved	02/12/2010 12:00:00 AM	ADDRESS	34.04533	-118.24959	2-12-10 - Supplemental is changes to previously approved lighting plans.  P/C is Energy and Emergency.  :: Changes to lighting and power layout and remove one area from the scope of work.  T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60810	16041-10001-09571	2268 W VENICE BLVD	90006	10	126B193   316	5074014048	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.04337	-118.30833	CHANGES TO ORIGINAL PERMIT. THIS IS PLAN CHECK AND PERMIT FOR 600A SERVICE UPGRADE. this is permit to be pulled under inspection ( not final).THIS IS ALSO PLAN CHECK FOR 3 REPLACEMENT PANELS. PERMIT FOR PANELS C, D, HP UNDER 16041-90000-25852COFFEE SHOP TENANT UNDER SEPARATE PERMIT.16041-10001-45423 --> 400 panel 16041-10000-45423  --> 20circuits	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60811	18041-20000-19985	13987 W AZTEC ST	91342	7	222B153   703	2508007007	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.3023	-118.43802	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM RATED AT 3.78KVA SYSTEM CONSISTING OF 26 MODULES WITH IQ7 MICRO-INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60812	09041-20001-23939	6141 W FRANKLIN AVE	90068	4	150A189   174	5586007025	R3-1	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM	08/20/2010 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	PIN	34.10539772	-118.32367026	Revision T-24 Energy calculation and lighting plan only. Permit is for additional panel for future lounge area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60813	18041-20000-45337	12033 N LOUISE AVE	91344	12	216B129   109	2606027054	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.29037	-118.51291	Plan check for a PV1 roof-mounted PV system. System size is 14.03 kWdc/12.7 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (46) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60814	13041-10000-29598	1 WORLD WAY terminal 4-T32	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	33.94469	-118.39817	"TITLE,24 PART 6 LIGHTING TO INSTALL ILLUMINATED BLADE SIGN 4'10""W' X 5/8""H FOR LAX TERMINAL 4, FOODCOURT. SIGN READS ""mamalade cafe"" total sign area = 8.33 sq ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60815	11041-10000-06907	136-139 BERTH	90731	15	018B201   824	7455019916	C2-2-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			Corrections Issued	04/17/2011 12:00:00 AM	PIN	33.74075762	-118.28191984	Install 2 additional  wharf  CAVOTEC-AMP receptacles for ship to shore connection to existing HV (6.6KV) Service.   <<<<<Additions to 09041-10000-13115>>>>>> (FY)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60816	19041-20000-38335	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	07/01/2020 12:00:00 AM	ADDRESS	34.25776	-118.46707	Plan check for power and energy for Tenant Improvement existing retail space, newly connected load exceed 400A. Existing 800A Service. Total area: 11,400 sq ft. B#19016-20000-30393	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60817	18041-10000-01382	1463 W SUNSET BLVD	90026	13	139-5A211 161	5406001043	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.0754	-118.25376	PC FOR RESTAURANT- ALL INTERIOR TI. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING AND RECEPTICAL. TOTAL AFFECTED AREA IS 613 SQ.FT. T-24 ENERGY ONLYB#17016-10000-31182	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60818	13041-10000-22446	6217 W WARING AVE 1-23	90038	4	141B185   263	5533026008	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			08/19/2013 12:00:00 AM	08/19/2013 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.08538	-118.33155	NEW FIRE ALARM SYSTEM FOR 4 STORY 23 UNIT APARTMENT.  131 DEVICES. 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60819	16041-10000-34021	3667 S MCCLINTOCK AVE parking A-CEN PLANT	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.02081	-118.29008	Installation of chiller inside central plant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60820	19041-10000-28079	612 E CENTURY BLVD 1-4	90003	8	091-5A207 103	6050036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	PIN	33.94508743	-118.26461689	PLAN CHECK ONLY, PERMIT FEES HAVE BEEN PAID FOR UNDER SEPARATE APPLICATION. _______________________________________________________________Building 4 of 5: Note. 5 applications under 1 plan, main service located in bld # 3Full plan check for power and energy for service upgrade to 600A for 22 residential units split up into muiltple buildings. Scope of work includes a new 600A serivce, new resedintial panels, and a new 600 A distribution board. Note building has provided 5 different building numbers for each building, 5 applications were genrated  under one planELECTRICAL Buiding 1: 19041-10000-27892Building 2: 19041-10000-28073Building 3: 19041-10000-28077Building 4: 19041-10000-28079*Building 5: 19041-10000-28081Building 1 B#: 17014-40000-00543Building 2 B#:17014-40000-00545Building 3 B#: 17014-40000-00546Building 4 B#: 17014-40000-00547*Building 5 B#: 17014-40000-00548	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60821	18041-20000-12948	3303 W WILSHIRE BLVD 4th Floor	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.06195	-118.29439	Plan check for Title 24 only in existing high-rise building office and break room expansion T.I. Total area: 10,940 sq ft. B#18016-10000-06668	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60822	15041-10000-18030	5121 N SAN FERNANDO ROAD WEST bldg 25	90039	13	165B205   119	5593011043	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.1457	-118.27194	FIRE ALARM SYSTEM REPLACEMENT. 273 DEVICES AND 1 PANEL. Hazardous location. Buildings 24 (H-3), 25 (mixed - H-2, H-3, F-2, B), 33 (F), and 34 (H-2, F, B).This permit covers building 25. (1 of 4). This is the main plan check application which shows all four buildings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60823	16041-20000-40396	10909 W HAMLIN ST	91606	2	180B173   665	2414028022	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			Reviewed by Supervisor	11/22/2016 12:00:00 AM	ADDRESS	34.18861	-118.36848	VOID PER APPLICANT REQUEST=====Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (10) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60824	18041-10000-32287	1800 W COLORADO BLVD	90041	14	162A225   123	5686009003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.13915	-118.20636	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60825	18041-10000-32231	140 W ANAHEIM ST UNIT A1	90744	15	030B205   411	7423002042	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	33.77972	-118.26333	PC for Title 24 only. Change of use from retail to ice cream palor. Scope includes new lights and receptacles. Total affected area is 1200 Sq. Ft. B#18016-10000-27235	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60826	10041-10000-06171	5333 W ZOO DR OTTER	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	1882.00	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	34.14867	-118.28623	PLAN CHECK POWER AND ENERGY FOR OTTER HOLDING (ANIMAL SHELTER).   BUILDING #0810-10000-02147.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60827	14041-10000-00753	1458 S SAN PEDRO ST #156	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in Fashion District retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60828	17041-10000-45028	911 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM			PC Info Complete	12/20/2017 12:00:00 AM	ADDRESS	34.08755	-118.34291	PC FOR WAREHOUSE TI FOR T-24 ENERGY ONLY.SCOPE INCLUDES NEW PANEL CIRCUITS EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA  6220 SQ.FT. B# 17016-10000-33842	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60829	15041-10000-37175	201 W 92ND ST	90003	8	094-5A203 223	6040036002	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	33.95292	-118.27616	PV1 INSTALL 2.65 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (10) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60830	13041-10002-32028	3969 N GOODLAND AVE	91604	2	162B161   292	2384018028	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	05/09/2014 12:00:00 AM	ADDRESS	34.14235	-118.4107	Modifications to approved set.  Changes to roof layout (approved by fire department).  $0 submittal fee due to Senate BIll SB-1222. PV1.  Install 11 kW DC roof-mounted PV system, interconnect with main service panel.  44 modules: Renesola JC250M-24/BB.  2 transformerless inverters: SolarEdge SE5000A-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60831	18041-20000-05194	7018 N ALABAMA AVE	91303	3	183B105   605	2138013009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			02/12/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.1979	-118.59888	New 3-story 9-unit apartment building.  New 800A 240/120V 3ph-4w service.  Plan check for power and energy. Building permit under 17010-20000-04911.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60832	15041-10000-24885	1609 W WILSHIRE BLVD	90017	1	132A205   392	5142009035	C2-2, C4-2, R4P-2, R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.05572	-118.27047	tenant improvement in existing commercial spaceplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60833	14041-20001-17299	1031 W 34TH ST ESH	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM			PC Approved	11/26/2014 12:00:00 AM	PIN	34.02400284	-118.2895744	[[[[11/7/14  PLANCHECK ONLY FOR POWER ONLY DUE TO FIRST TIME TENANT. PERMIT AND T24 ENERGY PLANCHECKED UNDER MASTER APP]]]]PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  THREE STORY COMMERCIAL BUILDING REPLACEMENT OF LIGHTING FIXTURES. ALL CIRCUITS EXISTING. THIRD FLOOR ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60834	09041-10002-05355	9480 W READCREST DR	90210	4	147B165   347	4352010046	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2010 12:00:00 AM			PC Info Complete	02/08/2010 12:00:00 AM	ADDRESS	34.09824	-118.40466	Plan check power for new electrical system with new 600A service, eeuipment, panels, and circuits for single family dwelling.((((((((((((((((((((((( Previosly three feeders E,F,G were fed from mau=in service panel. Now panel E, F are fed from panel G and total load decreased by about 45 amps. due to reduction of lights. 1-25-10((((((((((((((((((((((( 2-8-10  re-rout panel E and F , re-name panel G to panel H and re-rout panel Dand G from from H.))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60835	13041-10000-17301	5446 N NAGLE AVE PV 1	91401	4	174B157   926	2344015005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM			PC Approved	07/02/2013 12:00:00 AM	ADDRESS	34.16991	-118.42348	PLAN CHECK ONLY IN REFERENCE TO EXPRESS PERMIT APPLICATION NUMBER 13041-20000-15566. PV1 ROOF MOUNTED SYSTEM. [INVERTER: POWER-ONE # AURORA PV1-4.2-OUTD-S-US-Z |||| MODULES: TRINA SOLAR # TSM-245PC05/PA05.18]****************************************************************INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.  5.145 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60836	16041-20001-00128	5419 N TAMPA AVE	91356	3	174B117   599	2163014020	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM			Reviewed by Supervisor	01/15/2016 12:00:00 AM	ADDRESS	34.16954	-118.5536	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 11.772 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60837	17041-10000-25112	3570 S DENKER AVE	90018	8	120B193  1166	5041011902	OS-1XL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.02321	-118.30458	PC FOR EXISTING LIGHTING FOR MORE ENERGY EFFICIENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60838	14041-10000-13555	7300 W SUNSET BLVD	90046	4	147B181   664	5550018024	C4-1D	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			05/21/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	34.09784	-118.34981	PLAN CHECK FOR ENERGY FOR EXISTING RESTAURANT. SCOPE OF WORK IS FOR LIGHTING ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60839	14041-10000-04635	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.03396	-118.24117	Ti in the restroom area of the commercial Bldg. EPC is for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60840	12041-10000-29911	"12722 W MILLENNIUM BLDG ""B"""	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			01/23/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	33.9761	-118.41564	PLAN CHECK POWER AND ENERGY FOR NEW 4-STORY 103 UNIT APARTMENT COMPLEX. BUILDING 'B'. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED. BUILDING LOCATED IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60841	18041-10000-07142	9220 S COMPTON AVE	90002	15	094-5A213 192	6048022066	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/01/2019 12:00:00 AM		Issued	02/01/2019 12:00:00 AM	ADDRESS	33.95257	-118.24587	FULL PLAN CHECK TO A NEW 3 STORY 12 UNIT APARTMENT BUILDING WITH 9 TYPICAL PANELS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE LOAD,  600A, 120/240V, 1PH. B# 17010-10000-02258.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60842	13041-20000-02352	16254 W TUPPER ST	91343	12	198B137   587	2676016001	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.23912	-118.48689	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60843	19041-20000-08863	19552 W LEMARSH ST	91324	12	204B117   320	2726015001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.25531	-118.55958	Installation of 27 kWh energy storage system and associated distribution equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60844	09041-10001-16105	8039 S VERMONT AVE	90044	8	099B197   966	6033021018	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM			Corrections Issued	04/17/2012 12:00:00 AM	ADDRESS	33.96567	-118.292	"Application to approve ""As-Built"" set of drawings.  Misc lighting changes,  new panel and transformer, new lighting circuits for additional load.<<<<<<Change of Use of an Existing Historic Building which is now vacant .    New use for Church of Scientology Community Center and Classrooms.>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60845	15041-20000-03183	12257 W SATICOY ST	91605	2	186B165   244	2307015017	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.20861	-118.40062	PV1 SFD. TOTAL SYSTEM SIZE 4.5KW AC USING MICROINVERTER SYSTEM. TOTAL OF 21 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60846	14041-10000-34943	1436 S MAIN ST Unit 10	90015	14	124-5A207 304	5133012014	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.03434	-118.2617	Title 24 plan check only.  Total area = 840 sq. ft.Remove HID lighting and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60847	17041-10000-11982	4712 S NORMANDIE AVE	90037	9	111B197   636	5017004003	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Closed	08/28/2017 12:00:00 AM	ADDRESS	34.00017	-118.29999	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 9050 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60848	13041-10001-29549	18678 W KIRKCOLM LANE	91326	12	216B121    40	2870007002	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.29265	-118.54062	Expedited RSES plan check per applicant request. ((((PV1.  Install 9 kW DC roof-mounted solar array, interconnect with main service panel.  Iinverter: Fronius IG Plus V 7.5.  36 modules: Hanwha Hsl60p6-Pb-4-250TW.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60849	16041-10001-03937	20748 W CHATSWORTH ST	91311	12	207B109   350	2706011018	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.26425	-118.58605	PV1: Field correction by the inspector, removed 6 panels, total panels now is 24. System size now is 6 kW AC.(24) SW285 Mono     (24) Enphase M250This is supplemental to Permit# 16041-90000-03937	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60850	15041-10000-32670	10861 W WEYBURN AVE	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.06247	-118.44344	T-24. PC FOR ENERGY ONLY. TI TO EXISTINC COMMERCIAL BUILDING (RALPH'S AND TARGET). SCOPE INCLUDE NEW LIGHTING IN A MACHINE ROOM. TOTAL AREA IS 1000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60851	16041-10000-32607	116 E 16TH ST	90015	14	123A207    23	5133014014	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.03304	-118.26213	TITLE 24 FOR EXTERIOR OF EXISTING LOWRISE BUILDING.TOTAL SQ. FT.2660	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60852	13041-10000-33193	900 N NORTH BROADWAY	90012	1	135A215   238	5414013900	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Apartment			11/27/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.06408	-118.23726	Plan check for energy and power for a new building on 3 levels of under ground  garage and 5 levels of 237 apartments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60853	16041-20001-42753	9182 N KELVIN AVE	91311	12	198B109   125	2748036008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.23802	-118.58526	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv system roof-mounted on a commercial building. Interconnect with a 400A MSP. 30kW (10*3) ungrounded system. (120) 275W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60854	12041-10000-21592	1400 N SPRING ST	90012	1	136-5A217  81	5409004007	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM			Verifications in Progress	01/16/2013 12:00:00 AM	PIN	34.06649464	-118.2323089	Plan check for roof mounted 59.28KW photovoltaic system LA Conservation Corps Building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60855	15041-10001-32932	2001 S ALAMEDA ST	90058	9	118-5A215  80	5167014008	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM			PC Approved	01/11/2016 12:00:00 AM	ADDRESS	34.01787	-118.23982	REVISED PLANS TO REFLECT AS-BUILT CONDITIONS: CUs are supplied from new panels rated 65KAIC;FCs are supplied from existing panels(((((plan check for additional CU and FC UNITS  and Circuits THAT WERE INSTALLED WITHOUT PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60856	15041-10000-29128	100 WORLD WAY SPACE 128	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR ENERGY. T.I. TERMINAL 1 OF LAX. EXISTING RETAIL STORE. TOTAL AREA 1311 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60857	15041-10000-21320	830 W 34TH ST	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	PIN	34.02190161	-118.28374695	NEW FIRE ALARM SYSTEM 22 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60858	18041-20000-28095	3925 N FIGUEROA ST	90065	1	145-5A223 295	5451009002	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1994.00	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Issued	08/14/2018 12:00:00 AM	ADDRESS	34.09188	-118.21087	Plan check for a PV2 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (16) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60859	15041-20000-29952	555 S MATEO ST	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.03943	-118.23302	Plan check for power and Title-24 (energy).  Total area = 119,893 sq. ft. (indoor) + 43,000 sq. ft. (outdoor)    New 3 story commercial building with 5,000 amp, 480/277 volt service.  Buildings labeled 1, 2, 3, and 4 on plans are connected structurally.  Plan checker to verify fees (applicant used pre-cut check).  Energy fees to be included on submittal 2 (per EM).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60860	13041-10000-17358	700 WORLD WAY SOUTH	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	ADDRESS	33.94286	-118.39982	Tenant improvement for LAX terminal 7. United airlines. title 24 energy , emergency lighting and floor level: main concourse.((((((((((((((  MZ. permit issued under application #   13041-30000-01998 ))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60861	18041-10000-35920	8353 N FARRALONE AVE	91304	12	192B101   533	2010003047	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.22115	-118.61117	Plan check for a 5KW AC / 5.2KW DC roofmounted system with (16) modules and (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60862	11041-10000-01066	1875 S CENTURY PARK EAST 10th floor	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM			No Progress	01/20/2011 12:00:00 AM	ADDRESS	34.06115	-118.41457	T-24 and emergency lighting plan check for a portion of the 10th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60863	16041-30001-35551	4671-4681 E HUNTINGTON DR SOUTH	90032	14	142-5A231  87	5213013020	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.08562	-118.18389	11-07-2017 Changes to an approved set of plan. Changes include reduce main service breaker to 800AT and manufacture to Cutler Hammer series ratting. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60864	17041-10000-19781	1515 W 190TH ST ste 140	90248	15	060B193   379	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	33.85852	-118.30531	Title 24 plan check.  T.I. to existing commercial space.  Subpanels to remain existing with new lighting and receptacles.  Total area = 3,041 sq. ft.  Backroom plan check at request of applicant.6/29/17 switched to counter plan check       Building permit #17016-10000-14036	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60865	16041-20001-04866	10939 W VENTURA BLVD	91604	2	162B173   393	2366022022	(Q)C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	34.14033	-118.36859	03/08/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for energy only. T.I. to existing commercial nail salon.  Lighting (incl. emergency) and receptacles. 1,560 sq. ft.Permit pulled under application #15041-20000-06515.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60866	12041-20000-06969	8229 N SAN FERNANDO ROAD	91352	6	192B173   758	2409001011	[Q]C2-1L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.10	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	34.21949	-118.36988	Las Playas Bar remodelEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60867	11041-10001-20646	1002-1036 S DOREEN PL BLDG 5	90291	11	111B145   665	4243003037	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.00041	-118.46072	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60868	12041-10001-06507	6801 W HOLLYWOOD BLVD # 201	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	TENANT IMPROVEMENTS FOR A CANDY STORE W/SOME CANDY MAKING FACILITIES; COMBINE 2 TENANT SPACES. PLAN CHECK FOR POWER, ENERGY, AND EMERGENCY LIGHTING.5570 SQFT. This is the south store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60869	13041-10000-33543	1823 W SAN FERNANDO ROAD	90065	1	148-5A215 112	5442004013	[Q]MR1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.09963	-118.23469	Title 24.Remove HID light fixtures and replace with new fluorescent fixtures in a commercial building.Area 4725 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60870	19041-20000-42976	6535 W MELROSE AVE	90038	4	141B185   566	5524011014	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Apartment			10/22/2019 12:00:00 AM	07/21/2020 12:00:00 AM		Permit Finaled	04/13/2022 12:00:00 AM	ADDRESS	34.08361	-118.33812	New 2000A 208Y/120V 3ph-4w service, distribution, power, and lighting for new building. (45) new panels with lighting and power loads and a 40 HP elevator. T24 included. Total square footage = 46658 SfPer building permit # 16010-10000-00239* 33-unit mixed use building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60871	17041-10000-13631	701 S VERMONT AVE	90005	10	132B197   227	5094011024	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.05952	-118.2918	Title 24 plan check.  T.I. to existing juice shop.  Relocate 100 amp subpanel.  New lighting and receptacles.  Total area = 827 sq. ft.     Building permit #17016-10000-01753	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60872	14041-20000-17070	19957 W CANTARA ST	91306	3	192B113   664	2106001038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Expired	08/10/2016 12:00:00 AM	ADDRESS	34.21894	-118.56859	7KW PV1 roof-mounted system with (28)Canadian Solar  modules 250Px,  and Solaredge P300 power optimizers connecting through a Solaredge SE6000A-US  transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60873	12041-10000-19129	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM			Corrections Issued	08/27/2012 12:00:00 AM	ADDRESS	33.94386	-118.4047	((((((((((  This is tes tank from utility building lax, new xfrmer, panels and title 24      8-14-12))))))))))))))))core and shell plan review for the central utility plant at LAX airport	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60874	18041-20002-38952	4316 N LANAI ROAD PV3	91436	5	165B137   222	2284012028	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM			PC Approved	05/13/2019 12:00:00 AM	ADDRESS	34.14892	-118.49181	permit fees $0.00 by senate senate bill no.1222 and assembly bill.1414supplemental plan check only, for changes to approved set. changes include conduit and conductor size changes, note changes, and wire size calculation changes., clouded changes only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60875	17041-10000-40603	5927 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Public Safety Only			11/09/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	33.93319	-118.38745	NEW FIRE WARNING SYSTEM FOR A COMMERCIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60876	16041-20000-38198	11979 W WALNUT LANE 1-4	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			10/27/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.03749	-118.4591	New 4-story 4-unit apartment building with 400 A 120/240V 3-phase 4-wire service.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60877	17041-10000-37913	6154 N MELVIN AVE	91356	3	177B117   423	2153028017	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.18247	-118.55987	PV1, New roof mounted solar system using a central inverter with optimizers. PV system includes (40) modules, (2)inverters and load center. Total size is 11.8KWdc / 12.6 KWac.(40)Solarworld-SW295 mono(1)Inverter-SolarEdge SE5000H(1)Inverter-SolarEdge SE7600A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60878	14041-10002-21348	6201 W HOLLYWOOD BLVD 114	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			03/04/2015 12:00:00 AM			PC Approved	03/16/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	Full plan check per inspector's request under first time tenant.note. final fee is paid under original application.(((Energy plan check for TI from retail to an exercise Gym, suit number 114 from a commercial building. total area is 3714 SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60879	18041-10000-41070	2415 S WESTERN AVE	90018	10	123B193   349	5058013001	C2-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.03425	-118.30919	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60880	13041-20000-11903	250 S GRAND AVE	90012	14	130-5A211 190	5149010***	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.05328	-118.25074	fire alarm	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60881	14041-10001-09001	13151 W LAKE ST	90066	11	114B149   583	4244014030	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.00838	-118.45281	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTERS: SOLAREDGE SE3000A-US-ZB-U &(14) MODULES: TRINA SOLAR TSM-250PA05.18}}ORIGINAL APP#13041-20000-33141.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60882	18041-20001-46183	17655 W DEVONSHIRE ST pv3	91325	12	204B129    58	2733013009	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.25781	-118.51928	expedite per applicantpv3install roof mounted pv system sized 72KW AC interconnected with msp.  (277) sunpower spr-p17 modules(140) solaredge P800 optimizers(1) 43.2KW inverter(2) 14.4KW inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60883	18041-20000-07713	8500 W BEVERLY BLVD suite 103	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT (PITCHOUN). CONNECTRED LOAD <400A, TOTAL AFFECTED AREA = 1823 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60884	17041-20000-09232	4550 N VAN NUYS BLVD Suite A3	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 2,525 sq. ft.Note: Building application has been generated under 17016-20000-06915	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60885	19041-20000-34517	21050 W KITTRIDGE ST	91303	3	180B109   377	2148029022	(WC)NORTHVILLAGE-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	34.19099	-118.5916	Plan check for new fire alarm system for new 7 story multi-family building. New Fire alarm devices: 1408 and 71 power supply 1 FACPB#18010-10000-04971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60886	14041-20000-01951	7843 S AIRLANE AVE	90045	11	099B169   621	4106024009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	33.96777	-118.39034	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 20 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60887	18041-20000-15943	9301 N TAMPA AVE #14	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only in existing space T.I. retail space in Northridge Fashion Center Suite #14. Total area: 1,657 sq ftB#18016-20000-13192	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60888	13041-20000-30011	6431 N GEYSER AVE	91335	3	180B121   476	2127002008	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.18772	-118.54227	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.6KWAC. 17 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60889	06041-10009-09913	1633 N LA BREA AVE	90046	4	147B181   287	5548008010	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Apartment			05/04/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Closed	12/09/2011 12:00:00 AM	ADDRESS	34.10058	-118.34527	DELTA 15 REVISIONS TO APPROVED SET OF PLANS- CHANGE RECREATION ROOM TO A FITNESS ROOM; REPLACE FEEDER CIRCUIT BREAKERS WITH FULLY RATED FUSE DISCONNECTS. ALL CHANGES ARE CLOUDE AND IDENTIFIED WITH DELTA 15 MARKINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60890	19041-20000-40654	13113 W HARTLAND ST	91605	2	183B161   819	2327007124	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	PIN	34.19503918	-118.41865821	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 10.71 KW DC/8.16KW AC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH MICRO INVERTERS AND A 125A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60891	16041-10000-01547	13455 W MAXELLA AVE #135	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Issued	01/27/2016 12:00:00 AM	ADDRESS	33.9867	-118.44159	PC for energy only, T-24 to an existing retail space (eye glass store) One story building. Adding new power and ligting. Total sq ft = 1397	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60892	19041-10000-46518	101 N OCEAN AVE 1-58	90402	11	120B129   324	4410004***	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Approved	05/22/2020 12:00:00 AM	ADDRESS	34.0271	-118.51546	Power plan check for installation of 24 EV chargers amd switchboard size of 600A, 120/208V, 3ph, 4 wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60893	16041-10001-25220	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.20615	-118.41279	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS. CHANGES INCLUDE ADDITION OF CIRCUITS FOR MICROWAVE AND LIGHTING CHANGES FOR 3D PRINTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60894	15041-10000-26812	12777 W JEFFERSON BLVD BLDG E	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	33.9778	-118.41768	FULL PC POWER AND ENERGY FOR A NEW (3) STORY COMMERCIAL BLDG. 2000 A SERVICE 480/277 3 PHASE, 4W SYSTEM. SQFT = 52350. FEES PER APPLICANT MAY NEED READJUSTMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60895	16041-10001-44408	750 S GRAND AVE #30	90017	14	129A209   250	5144012058	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.04628	-118.25721	Changes to approved set.  Change of engineer.  Changes to single line diagram to reflect as built conditions.  Addition of new subpanel.  Changes to series rated circuit breakers.  Changes to roof plan.B# 16016-10000-24865	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60896	15041-20001-33426	23711 W DRACO WAY	91307	12	186B093   551	2027019030	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.20389	-118.6434	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. Project scope is the addition of a 5 kWac PV system onto an existing 7.2 kWac PV system. New system consists of (1) inverter, (26) modules, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60897	12041-10000-01162	6600 N TOPANGA CANYON BLVD #2062	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	alterations at a sport authority store plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60898	19041-10000-29944	695 S SANTA FE AVE	90021	14	124-5A217 215	5164019031	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	04/24/2020 12:00:00 AM		Permit Finaled	12/13/2021 12:00:00 AM	ADDRESS	34.03508	-118.23039	Full PC for new Restaurant and Bakery, Including outdoor dining area. eisting service size is 1000A, 480/277V, 3ph, 4Wires. Area of scope 2,877SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60899	10041-20000-25513	8251 N SAN FERNANDO ROAD	91352	6	192B173   712	2314003019	[Q]C2-1VL-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.10	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	08/01/2011 12:00:00 AM	ADDRESS	34.21987	-118.37047	"T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.""COMPLY WITHDEPARTMENT ORDER effective date 02/17/2010. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60900	19041-20000-53748	17409 W MAYFLOWER DR	91344	12	213B129   137	2607010005	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.28168	-118.51327	PV1. INSTALL 7.93 KW DC ROOFMOUNTED PV SYSTEM WITH (23) MODULES, OPTIMIZERS, (1) INVERTER (SE7600), AND (1) ENERGY STORAGE SYSTEM (5KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60901	17041-20000-32617	2505 N SUMMITRIDGE DR	90210	5	156B157   519	4386012030	RE40-1-H-HCR	South Valley, West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM			PC Info Complete	09/12/2017 12:00:00 AM	ADDRESS	34.12028	-118.42152	New 600 A 120/240V single phase service.  130 kW generator with ATS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60902	12041-20000-31187	2049 S CENTURY PARK EAST # 2300	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24 and emergency lighting plan check for a portion of the 23 floor.  Each exit sign shall be connected to two circuits, one from the normal source and one from the emergency source.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60903	14041-20000-26989	1985 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM			Reviewed by Supervisor	11/14/2014 12:00:00 AM	ADDRESS	34.06159	-118.20463	PC FOR POWER ONLY. PC OFR NEW HV DISTRIBUTION AND REPLACEMENT OF BUILDING SERVICE EQUIPMENT. NO CHANGE IN LOADS. REPLACEMENT FROM OLD TO NEW ONLY. PER APPLICANT, NO PATIENT CARE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60904	10041-20000-10969	6825 N BAIRD AVE	91335	3	183B125   941	2126023008	(Q)R3-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Public Safety Only			06/09/2010 12:00:00 AM	06/09/2010 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.19463	-118.53759	Plan check for new installation of fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60905	10041-20000-12290	11150 W OLYMPIC BLVD s.1020	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	06/28/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.03956	-118.43857	office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60906	15041-20000-20891	4302 N BELLINGHAM AVE	91604	2	165B165   666	2367004001	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Expired	08/04/2017 12:00:00 AM	ADDRESS	34.14875	-118.39856	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. USING STANDARD PLAN. TOTAL OF 20 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60907	18041-20000-40656	6320 N CANOGA AVE #220E	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check for Title 24 only in existing office T.I. Total area: 843 sq ft. B#18016-10000-30077	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60908	16041-20001-19806	540 S CATALINA ST	90020	10	135B197   936	5502022019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.06411	-118.29524	PV2.  Install 48.96 kW roof mounted PV system.  (2) separate PV systems on building occupying same rooftop.  System 1 of 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60909	19041-10000-13106	9600 S AVIATION BLVD ITF East-Station	90045	11	093B173   364	4128011907	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	33.94956	-118.37754	ITF-EAST, PC power and energy for LAX APM project, 40,450sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60910	12041-10001-14233	23656 W AETNA ST PV1	91367	3	177B093   633	2035006017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM			PC Approved	09/10/2012 12:00:00 AM	ADDRESS	34.17991	-118.64266	PLAN CHECK FOR INSTALLATION OF 5.5KW ENPHASE M215 MICROINVERTER PHOTOVOLTAIC SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60911	18041-10000-37815	5555 W MELROSE AVE BLD 11,12,-14,15,250	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.08363	-118.32191	NEW ELECTRICAL DISTRIBUTION EQUIPMENT FOR THE NEW HVAC UPGRADE IN BLDGS 11, 12, 14, 15 & 250 in Paramount Studios with a New 1000 KVA Med Voltage Xformer BULDING PERMIT: 18016-10000-31129	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60912	16041-20000-36716	2318 S UNION AVE	90007	1	124-5A201 299	5124007019	C2-1L-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM			PC Info Complete	10/17/2016 12:00:00 AM	ADDRESS	34.03426	-118.2837	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60913	19041-10000-53395	101 S THE GROVE DR	90036	4	138B177  1131	5512003045	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	07/29/2020 12:00:00 AM		Issued	07/29/2020 12:00:00 AM	ADDRESS	34.07256	-118.35874	TITLE 24 PLAN CHECK FOR A TI. TOTAL AFFECTED AREA IS 3306.8 SQAURE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60914	18041-10000-21499	21001 W DEVONSHIRE ST	91311	12	204B109   143	2706019033	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.25741	-118.59098	Energy plan check for a bank  T.I. Scope includes new lighting, equipment and receptacle with a total area of 4228-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60915	12041-20000-24417	1230 S MENLO AVE 1-60	90006	1	129B197   936	5076019031	R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			10/12/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.04815	-118.29051	fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60916	13041-10000-16837	9210 N SAN FERNANDO ROAD	91352	6	198B169   119	2538002046	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM	07/22/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.23693	-118.39033	PC FOR POWER ONLY. MATERIAL HANDLING SYSTEM FOR FEDEX. (E) MCC & PC3 to power (N) 480V MCCs  mcp02 and mcp01 respectively and their connected motors. design-build by kawal #796545. applicant brought check. FEES TO BE RECALCULATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60917	19041-20000-13174	249 N HOMEWOOD ROAD	90049	11	132B141    63	4403002003	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM			Reviewed by Supervisor	05/10/2019 12:00:00 AM	ADDRESS	34.06144	-118.48242	Plan check only for new 2-story SFD and accessory structures.  800A 208Y/120V 3ph-4w service.  Building permits under:18010-10000-0537418010-10000-0537618010-10000-05375	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60918	15041-20001-29703	11400 W CULVER BLVD	90230	11	111B161   400	4217015002	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			06/28/2017 12:00:00 AM			PC Approved	06/28/2017 12:00:00 AM	PIN	34.00072849	-118.41264563	06/28/2017 Changes to an approved set of plans. Service has changed from 800-amp, 120V/208V 3-phase to 1,200-amp, 120V/240V 1-phase. Other changes have been made to reflect new service capacity and type.*****Previous Work Description*****New 800A service. Adding new lighting including emergency. Plan check for power and energy.Note: Building permit has been filed under application number 14010-20000-03622	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60919	19041-10000-14323	777 S FIGUEROA ST 44TH FLR	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Energy plan check for an office TI located in the 44th floor of a high rise building. Scope includes new lighting and equipment with a total area of 13,096-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60920	16041-30000-29133	2029 S CENTURY PARK EAST 24th FL	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Titel 24 only in existing high-rise 24th Floor. Total ligting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60921	13041-10001-17191	11705 W NATIONAL BLVD	90064	11	120B153  1026	4257011025	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	09/26/2013 12:00:00 AM	ADDRESS	34.02268	-118.43912	REVISED PLANS SHOWING THE AREA OF THE TENANT SPACE IS 1500SF.NO OTHER CHANGES ON THE PLANSPLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. TENANT IMPROVEMENT. SQUARE FOOTAGE IS 1500sf. THERE IS NO EMERGENCY LIGHTING IN THE SCOPE OF THIS WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60922	19041-10000-37401	13060 W SATICOY ST	91605	2	186B161   435	2303023042	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.20712	-118.41771	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60923	13041-10000-30061	3503 E 3RD ST	90063	14	124-5A229 166	5179014002	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.03404	-118.19414	PV1, Install 2.5 kW DC roof-mounted photovoltaic system for a one story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US, power optimizer, and 10 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60924	19041-20000-33657	7239 N BALBOA BLVD Unit A	91406	6	186B133  1083	2227003***	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.20226	-118.50132	Plan check for PV roof mounted system, PV System size: 4.96KW DC with 16 PV Modules and 1 inverter(3.8KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60925	16041-10000-36637	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019007	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.25776	-118.46707	PC FOR POWER AND TITLE 24SCOPE INCLUDE TI FOR COMMERCIAL STORE (TARGET)TOTAL AFFECTED AREA 31447 SQ.FT. EXISITING SERVICE WITH NEW 1600A MAIN SWITCH BOARD (120/208) AND NEW SUB PANNELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60926	17041-10000-02274	9525 N DE SOTO AVE	91311	12	201B109   340	2746007016	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.24375	-118.58873	PC for Tile 24 only. Remove HID fixtures and replace exterior with new LED fixtures. Area: 29,600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60927	15041-20001-18845	19207 W VICTORY BLVD BLDG 1	91335	3	180B121   522	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.18674	-118.55154	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9KW DC.  34-CS6P255 MODULES  AND 1-SMA SB3000US, 1-SMA SB6000US. BUILDING # 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60928	17041-10000-06943	2027 S SANTA FE AVE	90021	14	118-5A217  50	5167012036	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Info Complete	03/03/2017 12:00:00 AM	ADDRESS	34.02033	-118.23042	PC for power only. New 800 Amp distribution board 120/240V being installed feeding existing loads.No new power added to existing distribution system.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60929	12041-10000-14674	433 S OLIVE ST	90013	14	130-5A211 118	5149029***	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			Reviewed by Supervisor	07/11/2012 12:00:00 AM	ADDRESS	34.05025	-118.25239	New Emergengcy generator for existing high-rise 'equipment' building.  New 3200A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60930	16041-20000-23085	1000 E WASHINGTON BLVD Unit 105	90021	9	121-5A211 373	5131008048	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.0256	-118.2533	TI to (E) laundromat in (E) commercial single-story retail building.  Greater than 400 A of newly connected load.  Plan check for power and energy. 3170 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60931	16041-20000-39033	5305 N LEGHORN AVE	91401	4	171B161   290	2345019022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.16692	-118.4161	Plan check for a PV1 roof-mounted PV system. System size is 8.7 kWac and consists of (31) modules, (31) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60932	13041-20000-33347	1060 E 53RD ST	90011	9	108B209   457	5103023033	CM-1, R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	33.99418	-118.25693	PC FOR T24 ENERGY ONLY. PER APPLICANT REQUEST. WORK DONE IN COMMUNITY ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60933	12041-10000-27734	2500 S NAVY WAY Admin. Bld	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			11/16/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	33.73363	-118.2408	Modify existing fire alarm system for Pola Maersk (port of LA) 1of 6 Admin. Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60934	15041-10000-20802	946 N ADELANTE AVE	90042	14	156A235    85	5716016002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.12302	-118.1713	PV1, ROOF MOUNTED SYSTEM TOTAL SIZE 6.54KW. 20 MODULES, 1 INVERTER AND 1 NEW 225 PANEL. (20) SUN POWER SPR-E20-327(1)SMA AMERICA SB6000TL-US-22-240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60935	14041-20000-19023	4329 N WOODMAN AVE	91423	4	165B157   536	2271018011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.14898	-118.4314	Energy plan check for 4 tenant spaces in back building on lot.  Front building energy plan check under 14041-20000-19019.  (((change of use from private school to 4 office spaces (1,416 sqft), no change in the interior work; change out exterior windows/ doors and restripe parking area.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60936	11041-10000-22069	3716 S HOPE ST	90007	9	117A203    30	5122025012	[T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			10/14/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.01651	-118.27956	NEW FIRE ALARM SYSTEM  for a new BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60937	18041-20000-30343	652 N EDINBURGH AVE	90048	5	141B177   687	5527016020	R1V3	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.08317	-118.36361	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of a Tesla PowerWall to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60938	15041-10001-22260	11821 W GWYNNE LANE	90077	5	153B141   106	4378037078	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM			Reviewed by Supervisor	07/20/2015 12:00:00 AM	ADDRESS	34.11581	-118.47468	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1. INSTALL 12.48 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(48) MODULES: KYOCERA KU2606CPA(2) INVERTERS: ABB PVI-5000-OUTD-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60939	12041-10000-30542	1628 N EL CENTRO AVE	90028	13	148-5A189 201	5546027400	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.10066	-118.32361	New fire alarm system for LA Fitness.  Installing 1 new fire alarm panel and 166 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60940	16041-20000-24414	627 N CARCASSONNE ROAD	90077	5	141B149   149	4362003039	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.08249	-118.44855	Plan check for New Single Famil dwelling with 1,200 A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60941	17041-10000-09358	6824 S ESPLANADE	90293	11	096B149   412	4116007059	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Apartment			03/23/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Closed	12/28/2018 12:00:00 AM	ADDRESS	33.95901	-118.44927	PC FOR POWER ONLY. SCOPE INCLUDE UPGRADING THE MAIN SERVICE PANEL TO 600A 120/240V 3 PHASE 4 WIRE. SITE IS ON A METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60942	11041-10000-12814	4950 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	ADDRESS	34.09786	-118.29745	REPLACE A 4000 A MAIN SWITCHBOARD AND MCC WITH A ONE FOR ONE REPLACEMENT, SAME MANUFACTURER AND LOCATION.  NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60943	13041-10000-12482	445 S FIGUEROA ST FLOOR 37	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Info Complete	05/23/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	TI TO 37TH FLOOR COMMONS AREA (CORRIDOR, ELEVATOR LOBBY, AND RESTROOMS) IN AN EXISTING COMMERCIAL HIGHRISE.  NEW LIGHTING.  4783 SQ FTTITLE 24 PLAN CHECK ONLY.  PERMIT ALREADY ISSUED UNDER EXPRESS PERMIT 13041-90000-09710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60944	11041-20002-19890	2025 N RODNEY DR	90027	4	150B197   393	5590006017	R3-1XL	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Apartment			12/13/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.10844	-118.28927	Modification to an approved set of plans. ((changes clouded delata 2. chnage in wire size to aluminum conductors. 2 clouded changes only. )))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60945	14041-10000-31200	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	ADDRESS	33.94286	-118.39982	Energy plan check for a commercial area  (club) T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60946	19041-20000-47348	15850 W MONTE ST #103	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	09/14/2021 12:00:00 AM	ADDRESS	34.31011	-118.47612	PC FOR ENERGY ONLY, SCOPE OF WORK IS A CHANGE OF USE ( OFFICE TO AGRICULTURAL SPACE) SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. NOTE FULL PLAN CHECK MAY BE REQUIRED, SUBJECT TO FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60947	14041-10000-09902	8958 W FOOTHILL BLVD	91040	7	207B185   438	2547026020	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.26199	-118.3275	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60948	13041-10000-11138	18679 W DEVONSHIRE ST	91326	12	204B121    71	2728028023	C2-1VL, QC2-1VL, QP-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	PIN	34.25808925	-118.53932955	13041-10000-11138T24 plan check for LA Fitness TI.  Moving fitness equipment and adding and replacing additional lighting. Single story bldg, 7206 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60949	11041-20000-21538	10974 W LE CONTE AVE	90024	5	135B149   562	4363017003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.06346	-118.4478	ENERGY PLAN CHECK RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60950	09041-10002-23338	1506 S FEDERAL AVE 1-60	90025	11	126B149   101	4261001017	R3-1/C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			04/07/2011 12:00:00 AM	04/07/2011 12:00:00 AM		Permit Expired	04/30/2013 12:00:00 AM	ADDRESS	34.04539	-118.45439	NEW MIXED USE 5-STORY  63UNITS APARTMENT WITH GROUND FLOOR RETAIL AND 2 LEVELS OF UNDER-GROUND PARKING PER ZONE VARIANCE . NOT: PLAN CHK FEE  IS TO BE RECALCULATED AS FEES WERE DETERMINED FROM OLD FEE SCHEDULE. ALSO, VARIANCE HAS TO BE FILED FOR SEPARATION OF FA PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60951	12041-10005-05678	1355 S FLOWER ST	90015	9	126A205   115	5134010019	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			03/04/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.03876	-118.268	Plan check for Title 24 residential control requirements per inspector request for apartment units.  (((NEW 7-STORY, 80 DWELLING UNITS (76 APARTMENTS AND 4 LIFE/WORK UNITS) COMPLEX WITH SUBTERRANEAN PARKING.PLAN CHECK POWER AND ENERGY. IN METHANE ZONE.VARIANCE TO SEPARATE THE FA PLANS WAS OBTAINED)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60952	17041-20000-45819	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	03/27/2021 12:00:00 AM	ADDRESS	34.04443	-118.29612	Plan check for power and energy. New 2-story multi-use building for Loyola High School - Assembly hall w/kitchen and auxilliary spaces, including locker rooms. New 1,200A 277/480V 3ph 4w distribution equipment fed from existing service. T24 area: indoor-75,435sqft. Project is located in a methane zone. Building permit application #17010-10000-04980. Outdoor T24 forms blank, update energy fee to include outdoor area when forms are completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60953	14041-20002-14051	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.0346	-118.45665	[[1/29/15  CHANGES TO APPROVED SET PER INSPECTORS REQUEST TO UPDATE PLANS. REMOVING DISCONNECT SWITCH FOR THE OPTIONAL STANDBY EMERGENCY GENERATOR ONLY . DELTA 6 CHANGE ONLY]]]]]CHANGES TO APPROVED SET OF PLANS. CHANGE CLOUDED DELTA 2 REVISIONS. INCLUDES NEW CIRCUITS AND NEW PANEL. PLAN CHECK AND PERMIT FOR ADDITIONAL ITEMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60954	14041-20000-04655	21240 W BURBANK BLVD BLDG 31	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.17307	-118.59314	"T24 PART 6 ENERGY FOR 1-STORY OFFICE BUILDING ('NORTHROP GRUMMAN'). SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 15,273 SQ, AND INCLUDES EMERGENCY LIGHTING.note: permit fee precalculated under ""inspection"" fee period"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60955	18041-20000-34272	13900 W LA RUE ST	91340	7	213B153   163	2616018008	M1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.27738	-118.43616	Plan check for power only. Upgrade service to 600A. all work inside building to be future.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60956	12041-20000-30200	12121 W BLUFF CREEK DR 3rd floor	90094	11	102B165   990	4211010099	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	33.97874	-118.40463	New lighting and receptacle and office partions for a TENANT IMPROVEMENT TO (E) OFFICE SPACE ON 3RD FLOOR. WORK INCLUDES NEW INTERIOR NON-BEARING PARTITIONS, SUSPENDED CEILING & MILLWORK.  Plan checked for T24 and emergency lighting only as space is existing and less than 400 ampere of load was added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60957	14041-20000-03660	14554 W VALERIO ST	91405	6	186B149   572	2218016004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Expired	04/07/2016 12:00:00 AM	ADDRESS	34.20472	-118.4508	Roof mounted PV system with 4.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60958	14041-10001-16501	5235 N BILOXI AVE	91601	4	171B177   479	2417017016	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.16592	-118.3584	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 7.14 KW DC SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS.(28) MODULES: TRINA SOLAR # TSM-250PA05.18(2) TRANSFORMERLESS INVERTER: AURORA PV1-3.6-OUTD-S-US-Z-A  AND AURORA PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60959	18041-20000-37301	20726 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.29294	-118.58526	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60960	12041-10000-08604	189 S THE GROVE DR #J-10	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.07125	-118.35662	PLAN CHECK POWER AND ENERGY FOR SUITE J-10 RETAIL TI. MORE THAN 400A OF CONNECTED LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60961	15041-20000-27257	3812 S 3RD AVE	90008	10	117B189   675	5034017032	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.01773	-118.32022	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60962	17041-10000-03184	10250 W SANTA MONICA BLVD # 2750	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""TYPO"" Ste. 2750.  Install new panels and its circuits, lights and receptacles. Total effected area: 1594 sq.ft. ."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
60963	13041-20000-23090	18076 W TULSA ST	91344	12	210B125   592	2715036019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.26964	-118.5268	Roof mounted photovoltaic system.  System is Ungrounded, 11.4 kw.  Plan check/Permit is for PV System only, Not for Service Upgrade or to derate the main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60964	13041-20000-33804	6606 W LELAND WAY	90028	13	147A185   164	5547025011	RD1.5-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.09692	-118.3335	New rooftop pv system for an existing sfr.  UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60965	12041-20001-22187	13023 W ARROYO ST	91340	7	216B161    31	2514002048	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.29134	-118.41681	Plan check for power and energy. Large warehouse. Karoun Dairies. 72692 total sqft (7648 outdoor).(((load relocation. pc for changes to approved set of plans. removed unused panel boards and relcated home runs to other panel boards. new lighting as well. plan check for new home runs and new lighting. clouded delta 2)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60966	13041-10000-03588	10412 N PEACH AVE	91345	7	204B145    79	2649018002	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	04/01/2013 12:00:00 AM	ADDRESS	34.25947	-118.46843	PV1 Solar installation for Single story house. Total system size: 3.43 KW. [Microinverter: Enphase Energy Model#: M215-60-2LL-S22] [Solar Module: REC Model#: REC 245 PE]. 14 Modules used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60967	14041-20000-25131	621 N HOLLAND AVE	90042	1	153A225   236	5469004003	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.11385	-118.20315	INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(16) SUNPOWER SPR-327NE MODULES(1) POWER ONE PVI-5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60968	14041-10001-06102	4818 E STRATFORD ROAD	90042	14	156A223    31	5476019002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1834.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	04/10/2014 12:00:00 AM	ADDRESS	34.12374	-118.20982	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.6-OUTD-S-US-Z-A(19) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60969	18041-20000-19742	1101 W PACIFIC COAST HWY	90744	15	036B201   746	7414024033	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM			Reviewed by Supervisor	06/06/2018 12:00:00 AM	ADDRESS	33.79062	-118.27646	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR COMMERCIAL BUILDING FOR 5.5KVA SYSTEM CONSISTING OF 24 MICRO-INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60970	13041-10000-03765	2011 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Public Safety Only			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	PIN	34.06587468	-118.19737837	INSTALLATION OF NEW FIRE WARNING SYSTEM FOR TWO STORIES BUILDING THAT IS UNDER RENOVATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60971	13041-10000-32756	1500 W PACIFIC COAST HWY BLDG I	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING I THIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60972	13041-10001-27153	11125 N DULCET AVE	91326	12	210B121   236	2717007020	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	34.27269	-118.54054	][][EXPEDITED PER APPLICANT REQUEST ][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH  MAIN; WORK DONE ON A non-STANDARD PLAN. 4 TOTAL STRINGS; LOAD CENTER WILL BE USED; DC UNGROUNDED; SYSTEM SIZE IS 8.5KW DC WITH (34) MODULES: TRINA #TSM-250PA05.18(2)POWER-ONE #PVI-3600-OUTD-S-US, PVI-5000-OUTD-S-US,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60973	14041-20001-06492	9420 N ENCINO AVE	91325	12	198B129    87	2766018020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	34.24176	-118.51545	(((EXPEDITE FEES)))PV1 ROOFMOUNTED MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 4.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60974	18041-10000-16836	19191 S VERMONT AVE 7TH FLR	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLAN CHECK FOR TITLE 24 ONLY FOR - 7TH FLOOR EXISTING CORRIDOR, ELEVATOR LOBBY AND RESTROOM RENOVATION ON APPROX. 2,230 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60975	15041-20000-39236	1446 N DEVLIN DR	90069	4	147B169   855	5560001020	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.09575	-118.38711	$0 permit fee is due to Senate Bill SB-1222. PV1, roof mounted solar panel, interconnected with 600A MSP.  21.5 kW AC system(86) modules: SW280MONO(86) microinverters: Enphase M250-72-2LN-S2(1) load center 125A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60976	16041-20001-29239	18321 W KINZIE ST	91325	12	201B125   177	2764003014	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM			PC Approved	09/07/2016 12:00:00 AM	ADDRESS	34.24832	-118.53273	EXPEDITE PER APPLICANT REQUESTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60977	12041-20000-07818	5757 N LANKERSHIM BLVD	91601	2	174B169   366	2338023009	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM			PC Approved	04/05/2012 12:00:00 AM	ADDRESS	34.17541	-118.3812	TI. Change of use to restaurant. 200A new load. Plan check for energy and emergency lighting only. 1029 sqft. Single story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60978	14041-20000-00925	13445 W GAGER ST	91331	7	204B157   513	2646023056	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.25669	-118.42612	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. USING 10 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60979	13041-10000-12361	15157 W TUBA ST	91345	7	204B145   394	2660017011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Finaled	08/13/2013 12:00:00 AM	ADDRESS	34.25644	-118.46283	PV1 ROOF MOUNTED SOLAR INSTALLATION IN A SFD. SYSTEM SIZE IS 4.41KW USING POWER OPTIMIZERS. 1 STRING OF 18 MODULES AND A SINGLE INVERTER. [INVERTER: SOLAREDGE # SE5000A-US |||| MODULES: TRINA SOLAR # TSM-245PC05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60980	15041-10002-30457	1315 E 3RD ST	90033	14	127-5A219  49	5172010004	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM			PC Approved	01/06/2016 12:00:00 AM	ADDRESS	34.045	-118.22602	Supplemental change to approved set of plan. Replace watstopper and add OC. This is PC only. Permit under 15041-10000-30457****SUPPLEMENTAL PERMIT 15041-10000-30457 TO CORRECT ADDRESS 242 S ANDERSON ST. TO 1315 E. 3RD ST LOS ANGELES, CA 90033 ALSO ADDING NEW ELECTRICAL PANEL METER INSTALLATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60981	11041-20000-16183	1270 W JEFFERSON BLVD 1-11	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/02/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29354	New 3.23 kw PV system for an appartment Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
60982	18041-20000-17972	20619 W CHESTNUT CIR (#279)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.29299	-118.58355	Plan check for PV roof mounted system, system size: 3.015kW system wtih 9 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60983	18041-20000-07899	13636 W BAYLISS ROAD	90049	11	138B133   166	4492016006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.07617	-118.50755	PV1.  INSTALL ROOF MOUNTED PV SYSTEM.  TOTAL SYSTEM SIZE = 10.6 KW CONSISTING OF 2 CENTRAL INVERTERS (SE 3000H-US AND SE7600A-US) AND 37 MODULES WITH P320 POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60984	19041-10000-05487	5051 E O'SULLIVAN DR	90032	14	136-5A235 233	5223006037	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.06811	-118.17289	NEW 5.67KW ROOF MOUNTED PV SYSTEM WITH 18 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60985	14041-20000-02036	5218 N HERMOSA AVE	90041	14	163-5A225 204	5669023012	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.14187	-118.2075	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60986	18041-30000-29175	2000 S AVENUE OF THE STARS #1000S	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.05868	-118.41546	Energy plan check for office T.I located in the 10th floor of a high rise building. Scope includes new light and equipment in the louge area with a total of 919-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60987	10041-10001-00308	8516 W 3RD ST	90048	5	138B173   780	4334009158	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM			PC Approved	02/11/2010 12:00:00 AM	ADDRESS	34.0731	-118.37718	PLAN CHECK ONLY FOR T-24 ENERGY. SUPPLEMENTAL APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60988	19041-10000-03386	7217 N WHITEHALL LANE	91307	12	186B089   653	2027050006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM			Verifications in Progress	11/20/2019 12:00:00 AM	ADDRESS	34.20252	-118.65413	PLAN CHECK FOR GROUND MOUNTED 12 KW AC PV SYSTEM, SCOPE OF WORK INCLUDES (42) 345W LONGI PV MODULES, (2) 6KW PRIMO INVERTERS, AND (1) 100A COMBINER BOX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60989	13041-20000-36105	627 W ROMULO ST	90065	1	144A219   163	5453017023	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.08957	-118.2213	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER. WITH POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
60990	19041-20000-33561	380 WORLD WAY T04-FB	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Title 24 only, install 1 electrical sings illuminated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60991	16041-10000-44999	10250 W SANTA MONICA BLVD STE. 1395	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Midici"" Ste. 1395.  Install new electrical equipments,  total affected area: 2,859 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60992	19041-30001-09201	3520 S HUGHES AVE ev2	90034	5	120B165    50	4313010046	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM			PC Approved	07/23/2019 12:00:00 AM	ADDRESS	34.02864	-118.40272	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60993	18041-10000-22477	9857 N MASON AVE BLDG 6	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.24955	-118.58012	PC FOR ENERGY ONLY, CORE AND SHELL FOR NEW 1-STORY  RESTAURANT. BUILDING 6 SCOPE OF WORK INCLUDES NEW INDOOR AND OUTDOOR LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 6518.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60994	18041-20003-40068	245 N TOYOPA DR	90272	11	123B129   686	4411024027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.03161	-118.52	12-19-2018 Changes to an approved set, changes include addtion of sub-panel and Back Gateway. All Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60995	16041-20000-36124	22714 W CREOLE ROAD	91364	3	168B097   564	2074010025	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.15518	-118.62271	"""$0 permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 19.5 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
60996	13041-20001-07155	9535 N ALDEA AVE	91325	12	201B133   606	2692016011	RA-1-H	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	34.24409	-118.50914	Modification to previously approved set of plans on sheet PV-1.  Only change is to relocate PV Panels.         <<<<Photovoltaic system on roof of single family dwelling.  Two inverters, 70 modules, one photovoltaic subpanel, and one new solar ready service panel>>>.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60997	19041-20000-27619	11401 N PORTER RANCH DR Bldg 1-10-Rec Room	91326	12	213B113   482	2701100005	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	06/14/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for a fire alarm system for a multi-building apartment complex. Fire alarm system consists of (1) FACP, (14) RPSs, (1) annunciator, and (560) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60998	18041-20000-22470	7644 N FARRALONE AVE	91304	3	186B101    34	2012021072	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.20945	-118.61016	Plan check for power and energy. Project site is an existing church. Project scope is a tenant improvement to a place of assembly. Total lighting area = 6,168 sq. ft.Note: Building application has been generated under 18014-20000-03213	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
60999	19041-10000-34962	305 S OCEAN FRONT WALK	90291	11	109-5A141 106	4286030024	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	09/14/2020 12:00:00 AM	ADDRESS	33.99451	-118.48022	PC for a new fire alarm system in a mixed use building, scope of work is one new fire alarm panel, and 47 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61000	12041-20000-14211	601 W 5TH ST	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	ADDRESS	34.05049	-118.25386	T.I. to existing high rise building on the 2nd floor, suite 210.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61001	18041-10000-33115	1203 N SOTO ST	90033	14	132A225   128	5202006010	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.05664	-118.20186	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61002	10041-20000-23093	444 S FLOWER ST 15th fl	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	energy plan check 15th fl	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61003	19041-10000-26370	7301 S FIGUEROA ST	90003	8	102B201  1086	6020025012	C2-1VL-CPIO	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	33.97347	-118.28294	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61004	15041-20001-27629	5417 N WHITSETT AVE	91607	2	171B165    20	2346011046	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	ADDRESS	34.16928	-118.40543	11/16/15 PC for energy only. Total area: 720sq.ftPermit fees paid under 15041-20000-27629((TI  EXISTING OFFICE, REWIRE.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61005	18041-10001-45401	1127 N LAS PALMAS AVE	90038	4	144B185   681	5532021029	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			07/17/2019 12:00:00 AM			PC Info Complete	07/17/2019 12:00:00 AM	ADDRESS	34.0916	-118.33657	REVISION TO PERMITTED SET OF PLANS-ADDITION OF GARBAGE DIUSPOSAL TO EACH OF THE 98 APARTMENT UNITSPLANS WERE REVISED AND LOADS RECALCULATE DTO REFLECT THESE CHANGES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61006	15041-10000-24099	1858 N VERMONT AVE	90027	4	150B197   976	5590015028	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.10478	-118.29156	PC FOR POWER PEAK SHAVE SYSTEM 30KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61007	16041-20001-02829	18527 W ELKWOOD ST	91335	3	189B125   581	2103022016	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.21315	-118.53706	Expedite per applicant request{{{{{{{{{{Plan check for PV roof mounted system. System size: 3.8kW with 15 modules and 1 inverter(3.8kW)}}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61008	13041-10000-04332	864 N STRADELLA ROAD	90077	5	141B149    64	4370003012	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2013 12:00:00 AM	05/29/2013 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.08532	-118.45204	NEW SINGLE FAMILY DWELLING 2 STORY HOUSE.  NEW 600 A SERVICE AND FULL ELECTRICAL INSTALLATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61009	17041-10000-45104	8110 N WEBB AVE	91605	6	189B169    45	2310007020	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.21806	-118.38961	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61010	16041-10000-17915	9201 W SIERRA MAR DR	90069	4	147B169   889	4392007014	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM			PC Approved	06/13/2016 12:00:00 AM	ADDRESS	34.09578	-118.3924	PC FOR POWER ONLY TO AN (E) TWO STORY SINGLE FAMILY DWELLING. SCOPE INLCUDES NEW 600A 120/208V 3 PHASE SERVICE/DISTRIBUTION BOARD. ALSO ADDING FIVE 225A SUBPANELS AND NEW LOAD EQUIPMENT.Permit Fees for electrical have been paid for in the building app #: 14014-20000-01864	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61011	10041-10000-18676	818 E 29TH ST	90011	9	118-5A207 325	5128015052	(T)(Q)R3-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	03/13/2013 12:00:00 AM	ADDRESS	34.01762	-118.26081	Installation of two photovoltaic arrays of micro inverters on the roofs of two carports.  the arrays supply existing distribution panels as shown on the plans.  System grounding and equipment grounding subject to inspectors's approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61012	16041-10001-24580	900 S FIGUEROA ST 30TH	90015	14	129A207   332	5138018***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.04604	-118.26272	recheck plans for lost set. stamp and issue permit as original. this is plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61013	19041-10000-06208	1414 W 25TH ST	90732	15	009B193   252	7460004901	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2973.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	33.72187	-118.31062	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61014	17041-20000-06789	15260 W VENTURA BLVD Ste 940	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM			PC Approved	03/02/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	TI to (E) commercial office space in commercial highrise building.  Plan check for energy.  Building permit issued under 17016-10000-03805	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61015	10041-10000-19494	800 S FIGUEROA ST 8TH FLOOR	90017	9	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.04771	-118.26116	TI IN AN EXISTING OFFICE AREA ON THE 8TH FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY. VARIANCE WAS SUBMITTED TO SEPERATE THE FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61016	18041-20000-22212	2660 N ANGELO DR Rest Room	90077	5	153B153     3	4382029***	A1-1-H-RPD-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.11964	-118.44259	Plan check for Title 24 Energy only in existing restroom and existing community fitness center. Total area: 953 sq ft. B#17016-30000-32186	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61017	13041-10000-25578	6832 S VICTORIA AVE	90043	8	102B185   633	4006024019	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	33.97592	-118.33222	Remove HID light fixtuers and install new flourescent fixtures.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61018	14041-20000-11804	3741 N ROYAL WOODS DR	91403	5	162B141   301	2280007020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.13893	-118.47247	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.5KW AC USING 2 TRANSFORMED INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61019	14041-20000-01614	2463 N SOLAR DR	90046	4	153B177   324	5571032009	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.11578	-118.35405	Roof mounted PV system with 16.17KWdc.  Note: $0 due to Senate Bill 1222, year 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61020	18041-10000-33952	7207 S AVALON BLVD	90003	9	102B205   900	6022022003	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.01	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	33.97449	-118.26533	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61021	18041-20000-08149	11916 W PICO BLVD	90064	11	123B149   970	4259039054	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.02999	-118.44856	Plan check for a fire alarm system for a multi-use building.  Fire alarm consists of (1) FACP, (1) annunciator, (5) RPS, and (235) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61022	17041-20000-10162	11766 W WILSHIRE BLVD 16th Floor	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.04804	-118.46227	TI to commercial space for fitness center and shower facilities.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61023	15041-20000-39016	6510 W HOLLYWOOD BLVD	90028	13	148-5A187 181	5547016003	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.10143	-118.33155	CHANGE OF USE FROM RETAIL TO RESTAURANT.PC FOR ENERGY ONLY, TOTAL AREA 1,077 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61024	13041-10000-20913	22843 W SHERMAN WAY	91307	12	183B097    69	2021017003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.20115	-118.62499	PV1.  Install 11.27 kW DC roof-mounted solar array, interconnect with main service panel.  {46 modules: Trina Solar TSM-245PC05/PA05.18} {Power-One Aurora PVI-5000-OUTD-US-Z and PVI-4.2-OUTD-US-Z}	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61025	16041-20001-21187	10355 W DIAMOND ST LOT 4	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM				"EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61026	14041-20000-03419	11214 W MORRISON ST	91601	2	168B173    16	2353016003	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			02/06/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.16065	-118.37499	NEW 6 UNIT APT. SERVICE SIZE 600A DELTA. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61027	19041-10000-37149	930 S ALAMEDA ST	90021	14	121-5A215 128	5166026034	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Issued	12/11/2019 12:00:00 AM	ADDRESS	34.02656	-118.23893	PLAN CHECK FOR POWER ONLY FOR FOR NEW 5000A SERVICE, WITH NEW DISTRIBUTION EQUIPMENT AND SUB-FEED TO EXISTING PANEL/EQUIPMENT19041-10000-37159PLAN CHECK FOR POWER ONLY - SCOPE INCLUDES INTERCONNECTION TO NEW SERVIVCE(19041-10000-37149) NOTED BELOW.  EQUIPMENT RATED AT 2500A 480/277V FEDING EXISTING EQIPMENT/PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61028	15041-10000-19118	242 W 42ND ST	90037	9	114A203   146	5111017009	R2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.00724	-118.2772	PV 1 ROOF MTD. 16 MODULES, 1 INVERTER, TOTAL SYSTEM SIZE 3,6KW AC. XFORMERLESS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61029	11041-20000-22136	3959 N LAUREL CANYON BLVD Suite E	91604	2	162B165   293	2369013006	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	ADDRESS	34.14266	-118.39509	New Dental officeEXTERIOR & INTERIOR T.I. FOR MEDICAL OFFICE &  (E) ROOF  REPAIR & REFRAMING .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61030	19041-10000-53373	5733 W VENICE BLVD	90019	10	126B177   396	5069015016	C2-1	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	07/22/2020 12:00:00 AM		Permit Finaled	11/19/2021 12:00:00 AM	ADDRESS	34.04348	-118.36318	PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW 400A 120/240V 3-PHASE 4-WIRE SERVICE/DISTRIBUTION BOARD. NEW PANEL BOARDS (2). NEW CIRCUITS, NEW LIGHTS AND RECEPTICLES. TOTAL AFFECTED AREA IS 6008 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61031	17041-10000-07494	8405 W BEVERLY BLVD	90048	5	138B173   413	5514011052	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.07622	-118.37338	PC FOR 2 NEW CIRCUITS TO DENTAL CHAIR AND PATIENT CARE AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61032	16041-10003-15988	5224 W LOS ENCANTOS WAY	90027	4	151-5A195  20	5588037007	RE11-1	Central	Hollywood	Los Feliz	Yes	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM			PC Approved	06/03/2016 12:00:00 AM	ADDRESS	34.11134	-118.30405	Changes to an approved set of plans, Note changes on delta 1. Changes include the module roof layout to match the field installation. (((PV1 9.81KW ROOF MOUNTED SYSTEM . 30 AC MODULES (E20-327-C-AC) AND PV MONITOR CONNECTED WITH A LOAD CENTER (60A).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61033	14041-20004-03004	7343 N RESEDA BLVD	91335	3	186B125   756	2118015003	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			08/02/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.20424	-118.53632	8/2/2018changes to an approved set of plans.  changes to reflect field conditions.  all changes are clouded and noted.  This is plan check only.New Mix-use - 2,280 sf Retail  & 40 Unit  Apt. Bldg. With 1st and 2nd floor private garage/retail and 3rd/4th/5th/6th floor 40-units Apt. bldg with bonus dencity.  New 1600A service, switchboard, panels, and branch circuit.  Plan check for power and energy.Note: Variance to separate fire alarm is submitted.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61034	18041-20003-19734	16152 W COVELLO ST	91406	6	186B137    96	2205022015	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.20741	-118.48542	11/16/2018changes to an approved set of plans.  changes noted delta 1.  changes to add AC disconnects.((((PV2.  Install 36KW AC System  roof mounted grid tied PV system  (108) PV modules with 3 inverters(12KW AC) connected to 125 A panel connected to 400A Service panel.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61035	14041-20000-35547	6320 N CANOGA AVE 11th Floor	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.18499	-118.59722	Plan check for energy only. TI for two break rooms and a conference room in an existing office on 11th floor of high rise office building. New lighting and receptacles. 673sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61036	18041-20001-06702	1697 S PACIFIC AVE	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM			PC Approved	09/06/2018 12:00:00 AM	ADDRESS	33.98722	-118.47211	09/06/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the lighting floor plan. Changes have been reflected onto the Title 24 forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the indoor lobby and the outdoor hotel entrance. Total indoor and outdoor lighting area = 2,385 sq. ft.Note: Building application has been generated under 17016-10000-00997	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61037	13041-20000-16834	19755 W VANOWEN ST	91306	3	183B117  1051	2135022042	(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	34.19397	-118.56386	T24 FOR SHELL FOR UNITS 24, 26, AND 28. TOTAL SQRFT 2621.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61038	17041-10000-45067	11249 N MONTGOMERY AVE	91344	12	210B141   168	2666022025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.27506	-118.48182	PC for new rooftop solar for 5.06kW system. Installing 22 modules with microinverters with 100A load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61039	17041-20001-20641	20801 W RINALDI ST	91311	12	210B109   548	2706007024	(T)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.01	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM			PC Approved	11/03/2017 12:00:00 AM	ADDRESS	34.27025	-118.58647	11/3/17changes to an approved set of plans.  changes noted delta 1.  changes to reflect field conditions.  increase conduit sized and change conductor size.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61040	15041-10000-31822	2831 W EXPOSITION BLVD	90018	10	120B185  1480	5044018025	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.02116	-118.32702	PC FOR ENERGY. REMOVE HID LLIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 8480 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61041	14041-20001-07802	1319 S OGDEN DR	90019	10	129B177   249	5086015009	RD1.5-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM			PC Approved	04/18/2014 12:00:00 AM	ADDRESS	34.05248	-118.36406	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61042	19041-10000-30870	2239 S PONTIUS AVE	90064	5	126B153  1005	4322024039	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.03869	-118.43767	REPLACE INDOOR AND OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61043	16041-20001-14142	163 E 111TH PL	90061	8	087A205    37	6073017030	R2-1	South Los Angeles	Southeast Los Angeles			2411.10	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	33.93404	-118.27161	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61044	16041-20000-21020	6712 W HOLLYWOOD BLVD	90028	13	148-5A185 145	5547014033	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.10134	-118.33659	Plan check for Title 24 only in existing projection room. Total area: 598 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61045	13041-20001-17228	9223 N DEERING AVE	91311	12	198B105   114	2746010048	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.23859	-118.59622	Changes from previously approved plans.  Removed one 150KVA transformer and  removed 45KVA transformer.  Plan check for power only.Note: Permit is under the original approval.*****New circuits and equipment for an existing low-rise commercial space.  Networking/Server equipment.  Plan check for Power, no change to lighting.  Project valuation is less than $200,000 per applicant - No green fee charged.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61046	13041-10000-01422	380 WORLD WAY T18	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	FULL POWER AND ENERGY.  DUTY FREE SHOP BLOCK T18 ON LEVEL 4 IN LAX.Fire alarm variance was submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61047	15041-10000-08152	525-625 E ANAHEIM ST	90744	15	030B209     7	7423023006	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	33.78047	-118.25663	New installation of (3) starter motors , (3) circuits for membrane gas condition and and a chiller system in a hazdous location of an existing facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61048	11041-20000-11975	3415 S SEPULVEDA BLVD SUITE-440	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM			PC Approved	06/10/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	TI TO SUITE 440 ON THE 4TH FLOOR OF A HIGH RISE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.  Over the Counter PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61049	16041-20002-36279	17331 W CUMPSTON ST	91316	5	174B133   784	2257011014	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.16954	-118.51117	Supplemental permit for (4) additional modules added to system.  Total system size upgraded to 5.16 kW.   (((plan check for PV roof mounted system. System size 4.3 kW with 20 PV modules and 20 microinverters connected to an existing pv system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61050	14041-10000-28999	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	33.95667	-118.4165	new service to supply existing buildings	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61051	14041-10000-10227	2842 S MOTOR AVE	90064	5	126B165   778	4308012008	R1-1-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.04015	-118.40446	PV1.Install 7.25 kW DC roof-mounted solar array on a 2 story-house, interconnect with main service panel.(1) Transformerless inverter: SOLAREDGE #SE6000A-US-ZB-U(29) Modules: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61052	14041-20000-07472	7727 W FORSYTHE ST	91042	7	208-5A195 154	2557001030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.26607	-118.30118	PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61053	19041-20000-27001	2712 N CASIANO ROAD	90077	5	156B141   115	4378030015	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	04/10/2020 12:00:00 AM	ADDRESS	34.12047	-118.47231	addition of (1) tesla ESS reated at 5KW to an existing PV system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61054	19041-10000-03978	2855 S CRENSHAW BLVD	90016	10	123B185  1229	5050017022	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.02969	-118.33534	Energy plan check for a financial office T.I located in a commercial building . Scope includes new lighting and equipment with a total area of 1325-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61055	17041-10000-38340	5621 W GEER AVE	90016	10	123B177  1304	5048026028	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Expired	09/17/2023 12:00:00 AM	ADDRESS	34.03097	-118.36608	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (18)MODULES-TRINA SOLAR 275 WATTS (18)OPTIMIZERS-P320 (1)INVERTER-SE5000H-US RGM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61056	19041-10000-17855	5223 W IMPERIAL HWY	90045	11	087B173   144	4129038011	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	33.93108	-118.3707	FULL PC POWER AND ENERGY FOR TENANT IMPROVEMENT TO EXISTING AUTO BODY REPAIR SHOP. WORK INCLUDES NEW PARTITIONS, FIXTURES AND FINISHES FOR NEW ACCESSIBLE RESTROOMS AND OFFICE SPACE. AREA OF SCOPE 15,334SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61057	12041-10000-03174	7712 N LOMA VERDE AVE	91304	3	189B109  1073	2109022024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	34.21038	-118.58949	Plan check for roof mounted 1.61KW Enphase M215 Microinverter photovoltaic system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61058	17041-10000-18964	1830 N CHEROKEE AVE	90028	13	150A185   307	5547004044	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			06/12/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.10404	-118.33464	Plan check for power and energy.  Service upgrade and electrical renovation for existing 5 story 64 unit apartment building with 9 hotel units.  New 2,000 amp 208 volt service and 30 HP fire pump.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61059	11041-10001-13005	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	ADDRESS	33.9867	-118.44159	Delta 3 changes to approved plans.   Existing commercial building.  Relocating the electrical room and all the electrical equipment within the electrical room to the new location on the second floor.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61060	17041-20000-33738	3520 W COUNCIL ST	90004	13	138B197   610	5501007025	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Issued	09/28/2017 12:00:00 AM	ADDRESS	34.07479	-118.28748	"Plan check for energy only. TI to suites A and B, no change of use (retail/merchandise - ""Eastside Camera""). New lighting (incl. emergency) - 2,803sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61061	13041-20000-25781	777 S FIGUEROA ST 16TH Floor	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.04828	-118.26116	T24 FOR EXISTING HIGHRISE OFFICE SPACE ON THE 16TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61062	11041-20000-01934	1915 S ARMACOST AVE	90025	11	123B149   235	4259020005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	03/25/2011 12:00:00 AM	ADDRESS	34.0356	-118.45508	replace existing  swichboard	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61063	18041-20000-40070	4009 W MELROSE AVE	90029	13	141B197   435	5539020013	C1-1D	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.08371	-118.28728	PV2.  Install roof mounted PV system sized 69.63 kW DC / 59.19 kW AC interconnected with MSP.  $0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61064	19041-20000-43740	20421 W ESMERELDA LANE	91326	12	216B109   257	2701082072	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.29143	-118.57892	Plan check for PV roof mounted system and Energy Storage device, PV system size: 7.26KW DC, 6.69KW AC CEC with 22 PV Modules and 22 microinverters, (1) Tesla PowerWall 2.0 13.5KWh. sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61065	18041-20001-27209	17171 W ARMSTEAD ST	91344	12	213B133   181	2607015054	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.28288	-118.50729	08-31-2018 Changes to an approved set of plans. Changes include remove 1 inverter and installed 2 inverters(7.6kW and 3.0kW) and load center. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61066	15041-10000-08238	3800 W WILSHIRE BLVD 207 C & D	90010	10	132B193  1202	5093027***	C2-2, R4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.06139	-118.30931	Full Plan check for a change of use from retail to a dental office. Total area is 3220-SQ feet. all panels are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61067	18041-10000-16890	7403 N DEERING AVE	91303	3	186B105   599	2111030020	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.20497	-118.59676	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61068	17041-20001-37283	18313 W MINNEHAHA ST	91326	12	207B125   605	2731013047	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM			PC Approved	11/16/2017 12:00:00 AM	ADDRESS	34.26011	-118.5323	EXPEDITED PER APPLICANTS REQUEST.ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.3 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61069	16041-20000-37476	15140 W GAULT ST	91405	6	183B145  1127	2220002030	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.19919	-118.4632	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (18) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61070	16041-10000-39068	6709 W SELMA AVE	90028	13	148-5A185 275	5547014039	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/05/2016 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	ADDRESS	34.09981	-118.3367	Full PC for new 6 story apartment building (109 units) with subterranean parking garage and retail on ground floor. 21 typical units. New service rated 4000 Amps 208/120 3phase 4wire. Total sqft =103498  Building B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61071	11041-10000-23989	19755 W VANOWEN ST	91306	3	183B117  1051		(Q)C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM			Reviewed by Supervisor	01/10/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	Plan check for power and energy for Chase Bank.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61072	16041-20000-40276	850 N MARIPOSA AVE	90029	13	141B197   109	5538006038	RD1.5-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.08618	-118.29884	permit fee $0.00 by state senate bill no. 1222Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 37.7kW (6kW*5+7.7kW) ungrounded system. (136) 340W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61073	16041-20000-26973	7401 N VINELAND AVE	91352	2	186B173   783	2315019006	R3-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	Apartment			08/01/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Expired	09/26/2018 12:00:00 AM	ADDRESS	34.20501	-118.37051	Plan check for a PV2 roof-mounted PV system. System size is 15 kWac and consists of (60) modules, (60) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61074	12041-10001-00784	10880 W WILSHIRE BLVD #100	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/30/2013 12:00:00 AM	09/30/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	New 300KVA UPS for a data room located in the lobby area suite 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61075	19041-10001-07685	4267 W YOSEMITE WAY	90065	14	159A219   293	5684017014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.12934	-118.22694	Change to approved set by changing the type of work from commerical to residential PV system.(((PV1 ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTER AND POWER OPTIMZERS. (15 MODULES), ( 15 POWER OPTIMZERS), (1) 3.8 KW INVERTER. TOTAL SYSTEM SIZE 5.4 KW DC AND 3.8 KW AC.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61076	15041-20000-32028	16621 W NORDHOFF ST	91343	12	198B137   973	2687024006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM			Reviewed by Supervisor	10/06/2015 12:00:00 AM	ADDRESS	34.23587	-118.49459	PV1 SFD. TOTAL SYSTEM SIZE 15.2KW AC USING 2 CENTRAL INVERTERS WITH 62 MODULES IN TOTAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61077	19041-10000-00624	17188 W GUNTHER ST	91344	12	213B133   145	2607015036	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.28339	-118.50796	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 23 MODULES (Q-CELL 305) , 23 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE6000H-US).  SYSTEM SIZE IS 7.02KWdc and 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61078	18041-20001-33347	507 3/4 E BOCCACCIO AVE	90291	11	108B149  1622	4237007013	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	33.98841	-118.45857	Revisions to approved plans.  Changes to emergency egress lighting system.  (((Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,644 sq. ft.Note: Building permit has been issued under 17016-30000-09405)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61079	14041-10000-27949	3456 S MOTOR AVE UNIT E	90034	5	120B161   364	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.02698	-118.40853	First time tenant plan check for a dental office, full plan check. all panels are existing, and branch circuits are new.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61080	18041-10000-25371	831 S HOPE ST	90017	14	129A209   267	5144020***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.046	-118.25993	T-24, TENANT IMPROVEMENT FOR NEW YOGA STUDIO IN EXISTING COMMERCIAL TENANT SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2835.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61081	18041-20000-45078	5214 N DEL MORENO DR	91364	3	171B113   277	2166041012	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.16448	-118.57652	Plan check for a PV1 roof-mounted PV system. System size is 18.55 kWdc/16.4 kWac and consists of (2) inverters, (53) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61082	18041-20000-32575	12733 W SUNSET BLVD	90049	11	132B137   357	4405020013	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Issued	12/04/2018 12:00:00 AM	ADDRESS	34.05699	-118.48693	service upgrade 600 amps to an existing SFD. plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61083	19041-20000-09447	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	11/20/2020 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement to a lab. Total lighting area = 2,715 sq. ft.Note: Building application has been generated under 19016-20000-07477	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61084	14041-20000-00442	9644 N PINE ORCHARD ST	91331	7	201B161   969	2624013***	(T)(Q)RD5-1, RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Issued	01/17/2014 12:00:00 AM	ADDRESS	34.24515	-118.40932	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61085	12041-20000-18511	601 S FIGUEROA ST	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I. to a high rise building portion of the 47th floor.  Install general/emergency lighting.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61086	18041-10000-10513	8500 W BEVERLY BLVD # 770	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	INTERIOR NON-STRUCTURAL TENANT IMPROVEMENT TO EXISTING TENANT SPACE WITHIN MALL. WORK TO INCLUDE(N) NON-STRUCTURAL WALLS, (N) INTERIOR FINISHES, (N) CEILING, (N) LIGHT FIXTURES, (N) ACCESSIBLE UNISEX RESTROOM. NO CHANGE IN USEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61087	14041-10000-15692	11755 W WILSHIRE BLVD	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	PIN	34.04869377	-118.46238681	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOMS ON 17TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61088	09041-10003-18410	410 N HAWAIIAN AVE	90744		027B201    26	7417010900			HARBOR CITY	WILMINGTON			Electrical	Electrical	Apartment			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	33.7736	-118.27616	DELTA 5 CHANGES TO THE APPROVED PLANS : CHANGE SOME LUMINAIRES IN THE COURTYARD FOR ONES HAVING THE SAME WATTAGES ANDADDED RECEPTACLES IN COMMUNITY ROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61089	18041-10000-22873	8500 W BEVERLY BLVD 764	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Issued	07/03/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for a retail T.I. Scope includes new lighting and equipment with a total T-24 area of 2,415-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61090	17041-20000-34470	14331 W JOY DR	91331	6	198B153  1035	2644027247	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24145	-118.44565	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61091	14041-20001-15000	19325 W ROMAR ST	91324	12	204B117   307	2726017001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.25551	-118.5546	Fee for expedite only.*****New roof mounted PV system with transformerless inverters.  Total system size 11KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61092	19041-10000-03317	6150 N LAUREL CANYON BLVD	91606	2	177B165  1100	2334011029		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	FULL PLAN CHECK FOR A FIRST TIME TENANT, NEW THEATER. SCOPE OF WORK INCLUDES NEW 2000AMP DISTRIBUTION BOARD CONNECTED TO AN EXISTING SERVICE. SCOPE OF WORK INCLUDES NEW TRANSFORMERS, PANELS AND PERFORMANCE METHOD T-24 FORMS. TOTAL SQ. FT. 51467.B#19016-10000-01525	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61093	19041-10000-10855	1515 W 190TH ST STE 528	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	PC for TI T-24 only. Scope area 2392SqFt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61094	16041-20000-45164	10543 W PICO BLVD	90064	5	126B157   184	4315005007	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04459	-118.42037	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,976 sq. ft.Note: Building application has been created under 16016-10000-19903	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61095	13041-10001-31559	22626 W BURBANK BLVD	91367	3	174B097   579	2040013015	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.17177	-118.61995	Expedited RSES plan check per applicant request.(((PV1, Install 3 kW DC roof-mounted solar array for 1-story house, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 12 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61096	19041-10000-43414	10950 S CENTRAL AVE	90059	15	088-5A211 269	6070006005	C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	11/03/2020 12:00:00 AM		Permit Closed	04/26/2024 12:00:00 AM	ADDRESS	33.93574	-118.25399	Plan check for new service 600A, 120/208V, 3ph, 4wire and (5) EV-chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61097	15041-20000-38570	20701 W KINGSBURY ST	91311	12	207B109   395	2706011025	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Refund in Progress	01/05/2017 12:00:00 AM	ADDRESS	34.26373	-118.58457	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (31) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-FRONIUS #PRIMO 7.6(1) COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61098	17041-10002-02377	433 S SPRING ST	90013	14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.04822	-118.24907	Supplemental Plan check for all changes noted as Delta - 5, 7, 12, 13,14, 16, 18, 20, 21, 22, 23,  24, 26 (13 pages of narrative is included) <<<<PC FOR POWER AND ENERGY. EXTENDING  OFFICE  ON THE LEVEL 2 MEZZANINE, AND T.I FOR  OFFICE AND RETAIL IN A 13 STORY BUILDING.  SHELL ONLY.  NEW SERVICE 5000A 480/277 V. TOTAL AREA  38408 SQ FT.B# 16014-10000-04123>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61099	10041-20000-23493	10851 W LA TUNA CANYON ROAD	91352	2	195B173    39	2408004021	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	34.23447	-118.36768	Relocate load to main switchboard with new 200amp meter.  Per applicant,  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61100	11041-10000-25644	10227 N MASON AVE 1-50	91311	12	204B109   215	2741025038	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Apartment			12/01/2011 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.25626	-118.58016	New 50 unit apartment building with aprox, 75,000 sq. ft.  New 1600A service, with three 600A main panels and 50 sub panels.Note: Fire Alarm system under 11041-10000-27684	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61101	19041-10000-26536	3620 S VERMONT AVE	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Apartment			07/11/2019 12:00:00 AM			PC Info Complete	07/11/2019 12:00:00 AM	ADDRESS	34.02213	-118.29133	ENERGY PC FOR TI OFFICES, SCOPE AREA 700SF BUILDING PERMIT#: 19016-10000-13416	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61102	14041-10000-03694	1218 S SAN PEDRO ST	90021	14	123A211    33	5132012052	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	PIN	34.03294443	-118.25339932	T24 only. Remove HID light fluorescent fixtures and replace with new fluoresent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61103	14041-10000-32948	11417 N TWIN HILLS AVE	91326	12	213B117   352	2822014009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.27843	-118.55458	PV1 5KWdc. 240V. microinverter. STD. 1story. Roofmount. [(20) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(20)modules: {Renesola {JC250M-24/B6}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61104	12041-20001-22363	11766 W WILSHIRE BLVD # 100	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM			PC Approved	11/16/2012 12:00:00 AM	ADDRESS	34.04804	-118.46227	T.I. to an existing office, change to lighting.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, No emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61105	14041-10002-30464	500 S SANTA FE AVE	90013	14	126A217   245	5164004010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.04107	-118.23124	CHANGES TO APPROVED PLANS TO MATCH FIELD INSTALLATION, INCLUDE ADDITIONAL PANELS AND CIRCUITS. 4,000 Amp Service for new office Building. NEW 4-STORY W/ MEZZ. OFFICE BLD'G. 98,825 S.F. (4-STORY TYPE IIB OVER 1-STORY TYPE IA)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61106	18041-20000-01561	5042 W VENICE BLVD	90019	10	126B181   110	5067002003	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.04514	-118.34851	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT.  CHANGE OF USE FROM (E) CHILD CARE TO (N) RETAIL.BUILDING PERMIT # 18016-20000-01296	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61107	17041-20000-46292	18938 W VENTURA BLVD	91356	3	174B121   466	2161001037	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM			PC Info Complete	12/29/2017 12:00:00 AM	ADDRESS	34.17229	-118.5461	Tenant improvement to (E) restaurant.  Plan check for energy.Express permit for project issued under 17041-20000-38396.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61108	11041-10000-08374	6120 N LINDLEY AVE BLDG 5	91335	12	177B125   657	2123024025	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	09/12/2011 12:00:00 AM	ADDRESS	34.1812	-118.52711	NEW FIRE ALARM FOR CHILD'S WORLD SCHOOL BUILDING #5.  3 SEPARATE BUILDINGS USING ONE CONTROL PANEL.  BUILDING #1 (6120 LINDLEY), BUILDING #5, AND BUILDING #2 (61121 LINDLEY).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61109	12041-10001-29311	13455 W MAXELLA AVE #250	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 12041-10000-29311.  DELTA THREE CHANGES CLOUDED IN PLANS, CHANGE TO P3 MODEL AND MANUFACTURER AND ADDITION OF FOUR C1 TYPE LUMINAIRES ****************************************************************************12041-10000-29311 DESCRIPTION: PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT (SETTEBELLO RESTAURANT) #250 . FULLY SPRINKLERED SPACE. EXISTING MARKETPLACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61110	10041-10003-03918	3327 E SABINA ST Bldg C	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM			PC Approved	12/22/2011 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 3 revisions; added receptacle outlets and revised switches to previously approved branch circuits. Panelboard load schedule updated for the added outlets.(NEW COMMUNITY CENTER FOR NEW APARTMENT BUILDINGS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61111	17041-10000-28424	11845 W OLYMPIC BLVD # 1110W	90064	11	123B149   463	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/18/2017 12:00:00 AM	ADDRESS	34.03291	-118.45177	PC for T24 only for office TI in existing office spaces. Total affected area is 958 sqft. Installing new lights and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61112	17041-10000-10833	3746 S MCLAUGHLIN AVE	90066	11	114B157   621	4234011033	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/20/2017 12:00:00 AM	ADDRESS	34.00966	-118.42521	Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect with existing array.  System size = 3 kWac.  Central inverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61113	14041-10000-17891	2582 N LOMBARDY BLVD	90032	14	139-5A233 124	5217023020	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.07662	-118.17616	Install roof mounted solar pannels on existing residential building.  Total system size = 3 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61114	15041-20001-18506	19207 W VICTORY BLVD #2	91335	3	180B121   522	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	34.18674	-118.55154	Plan check for PV roof mounted system. System size: 4.0kW with 10 modules and 1 inverter (4.0kW) connected to 125A unit panel and connected to Meter Bank(600A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61115	14041-20001-14318	7544 N LILLA PL	91304	12	186B089   133	2027035022	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.20897	-118.64522	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 11kW(1) Power-One #Aurora PVI-5000-OUTD-US-Z-A transformerless inverter(1) Power-One #Aurora PVI-6000-OUTD-US-Z-A transformerless inverter(55) Trina Solar #TSM-255PA05.18 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61116	16041-10002-29518	1825 N LAS PALMAS AVE 1-118	90028	13	150A185   301	5547001022	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			08/21/2018 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.10476	-118.33652	CHANGES TO APPROVED SET OF PLANS(DELTA 6 ONLY) - CHANGES INCLUDE ADDITION AND RELOCATION OF LOADS, NEW FIRE PUMP AND JOCKEY PUMP, TITLE 24 REVISIONS(UPDATE TO MOST LIGHTING BOTH INTERIOR AND EXTERIOR), RELOCATION OF MECHANICAL EQUIPMENT ON ROOF, TYPICAL UNIT CONFIGURATION(ALL UNITS, WITH 3 NEW TYPICAL UNITS-SAME OVERALL #), UPDATED LOAD SUMMARY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61117	18041-10000-05347	13422 W SATICOY ST	91605	2	186B157   183	2303024011	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.20868	-118.4256	T-24 only, Remove Outdoor HID fixtures and replace with new LED fixtures. Total Sq. Ft. 10150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61118	19041-20000-08616	4133 N MATISSE AVE	91364	3	165A105   177	2173005013	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.14563	-118.60157	PV1.  Install 9.57 kW DC / 10 kW AC roof mounted grid tied PV system.  (33) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61119	16041-10001-09811	8041 W WORLD WAY WEST	90045	11	090B157    96	4129026910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Closed	09/04/2018 12:00:00 AM	PIN	33.94111969	-118.42968741	02/27/16Changes to an approved set of plans. All changes are clouded under delta 4. Changes include adding a new 2500A 277/480 3 phase 4 wire service/distribution board(MSB), and relocating loads from existing 2000A distribution board to new service, replacing circuit breaker ratings on single line, and revising floor plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61120	15041-20000-43768	6946 N BERQUIST AVE	91307	12	183B093   458	2026021008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.19594	-118.63439	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (36) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61121	18041-20001-00858	7320 N HILLSVIEW CT	91307	12	186B089   513	2027047004	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.20479	-118.65146	expeditepv1install roof mounted pv system sized 10kw interconnected with msp with three tesla battery back up.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61122	15041-10000-25985	1719 S KELTON AVE	90024	5	129B153   363	4324029038	[Q]R2-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Expired	09/25/2017 12:00:00 AM	ADDRESS	34.05099	-118.44079	PV1, INSTALL 3.71 KW DC SOLAR ARRAY ON A SINGLE FAMILY HOME.(14) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61123	11041-10001-26842	7703 W MELROSE AVE	90046	5	141B177   549	5527008028	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM			PC Info Complete	08/28/2012 12:00:00 AM	ADDRESS	34.08389	-118.35765	Change the approved plan. Addition of a track light and remove type F luminaires. EPC is for change. ((((((((((((((T.I. to an existing retail building.  No suite number.  New lights and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.)))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61124	18041-20002-11355	20433 W NORDHOFF ST	91311	12	195B109    61	2781001036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.232	-118.57867	08/22/2018 Changes to an approved set of plans. Module count has been reduced to (218) and module model has changed. Inverter sizes have remained the same. *****Previous Work Description*****Plan check for a PV2 roof-mounted PV system. System size is 66.6 kWac and consists of (2) inverters, (233) modules, (1) transformer, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61125	10041-10000-01879	800 E 12TH ST 1-119	90021	14	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM			PC Info Complete	02/03/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	Title 24 for unit 109.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61126	12041-10001-15218	19600 W REDWING ST	91356	3	174B117   522	2164018003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2012 12:00:00 AM			PC Approved	07/05/2012 12:00:00 AM	PIN	34.1703512	-118.56033133	NEW 7.92KW, ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM FOR AN EXISTING SINGLE FAMILY RESIDENCE.  PLAN CHECK ONLY.  Permit is on main application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61127	15041-10000-16453	5100 W ZOO DR	90027	4	168B201    51	5593002917	OS-1XL-H-RIO	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.15543	-118.2841	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED LIGHT FIXTURES. TOTAL AREA 621 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61128	15041-10000-40418	3003 S VINEYARD AVE	90016	10	120B181   248	5057025016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.02787	-118.34714	PV1 SFD TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 33 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61129	13041-10000-25799	12855 W RUNWAY ROAD BLOCK 1	90094	11	102B157   395	4211033036	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	33.97556	-118.41956	METHANE MITIGATION GAS DETECTION SYSTEM IN AN 4-STORY ABOVE GRADE BUILDING APARTMENT, 2-LEVEL BELOW GRADE. ACTIVE SYSTEM, METHANE ZONE , SHOWN ON ZIMAS. LEVEL-5 METHAN LEVEL PER TABLE 1-A. TEST DATA PROVIDED ON SHEET # GM-100.0	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61130	17041-10000-23818	8141 S GULANA AVE	90293	11	096B153     1	4115021800	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM			PC Info Complete	11/07/2017 12:00:00 AM	ADDRESS	33.96169	-118.43753	PC FOR POWER ONLY FOR AN EXISTING STORAGE FIELD. SCOPE INCLUDES ADDING A NEW 4160V 3 PHASE 3 WIRE SERVICE/METERING SWITCHGEAR, NEW TRANSFORMERS, ONE NEW 3200A 480V DISTRIBUTION BOARD, AND REFEEDING EXISTING DISTRIBUTION EQUIPMENT TO EXISTING MOTOR CONTROL CENTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61131	11041-10000-07730	9301 N TAMPA AVE # 117	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	05/25/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI - REMODEL OF (E) RETAIL SPACE INCLUDING DOORS, PARTITIONS, CEILINGS, LIGHTING, FIXTURES, FINISHES AND MILLWORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61132	14041-20000-31367	9671 W SOMBRA VALLEY DR	91040	7	204B181   307	2545026005	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.25229	-118.34278	Roof mounted PV system with Enphase inveter model M215-60-2LL-IG.  Total system size 6.12KW.Note: the solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61133	13041-20001-21124	14326 W CHANDLER BLVD PV1	91401	4	171B153   130	2248016***	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	Apartment			09/12/2013 12:00:00 AM			Corrections Issued	09/12/2013 12:00:00 AM	ADDRESS	34.16822	-118.44508	(((supplemental application for changes to approved set of plans. now using 6 modules. application is commercial application. inspector verify that service point is at tenants service panel. if all tenants share a common service point, refer applicant to resubmit plans to show full distribution. )))INSTALL SOLAR PHOTOVOLTAIC SYSTEM (2.6KW)  MICROINVERTER STANDARD PLAN. USING 10 MODULES. PLAN CHECK ONLY. PERMIT ALREADY ISSUED UNDER EXPRESS PERMIT 13041-20000-19523	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61134	18041-10000-23562	12760 W OSBORNE ST	91331	7	204B161   652	2624001900	PF-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Issued	10/26/2018 12:00:00 AM	ADDRESS	34.25297	-118.41083	"PLAN CHECK FOR POWER ONLY - PLAN CHECK INCLUDES 800A DISTRIBUTION EQUIPMENT FOR NEW CAR CHARGERS - SCOPE OF WORK IS REMOVAL OF 125A FEEDER FROM SWITCHBOARD ""MS"" AND CONNECT EV SYSTEM TO DWP TRANSFORMER FOR NEW 800A DUAL SERVICE FROM DWP."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61135	15041-20000-02024	2667 N QUEEN ST	90039	13	147A213    59	5442012001	R2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.0986	-118.24504	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61136	19041-20001-14859	301 N CAROLWOOD DR	90077	5	141B157    34	4358005017	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.08337	-118.42821	SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO SINGLE LINE DIAGRAM FEEDER SIZE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61137	11041-10000-00239	9118 W PICO BLVD	90035	5	132B169   888	4305001004	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM			PC Approved	01/07/2011 12:00:00 AM	ADDRESS	34.0551	-118.39059	Ti in an existing retail store. EPC is for T24 & Energy. ( Permit was pulled under# 10041-30000-21307)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61138	19041-20000-34222	2446 N WILD OAK DR	90068	4	153B193   136	5580027026	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM			Reviewed by Supervisor	09/18/2019 12:00:00 AM	ADDRESS	34.11509	-118.31032	PV1.  Install 12.285 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (39) modules with 11.4 kW rated inverter; (2) 13.5 kWh energy storage units.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61139	11041-20000-24192	1425 W 186TH ST	90248	15	060B193   190	6108014037	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2011 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	33.8621	-118.30041	PLAN CHECK ROOF AND GROUND MOUNTED 8.9KW PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61140	19041-10000-20938	2001 E 7TH ST	90021	14	124-5A217 238	5164020011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	03/23/2023 12:00:00 AM	ADDRESS	34.03474	-118.23211	PC FOR POWER ONLY, CORE & SHELL CHANGE OF USE FROM OFFICE TO RESTAURANT & COFFEE SHOP. SCOPE OF WORK INCLUDES NEW 800AMP SERVICE, PANELS AND AC UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61141	10041-10001-21507	8727 N VAN NUYS BLVD	91402	7	195B149   598	2653002010	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	34.22813	-118.45039	TI in an existing office building on the 1st floor.  Approx 100 Amp of new load added.  Install new panels, circuits, lights & replace existing old AC units.  Supplemental permit to existing Permit # 10041-10000-21507.   Plan check for T-24 energy calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61142	17041-10000-04524	9800 S GRAPE ST	90002	15	093A217   176	6046019930	OS(UV), R3(UV), RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	33.94688	-118.23654	Plan check for New Fire alarm system for modular builidng. Total Fire alarm devices: 57 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61143	12041-10000-20431	2020 S PENMAR AVE	90291	11	111B149  1443	4242019***	RD3-1XL	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Expired	12/01/2014 12:00:00 AM	ADDRESS	33.99923	-118.45426	2.45 KW solar (Enphase M215 Microinverters) roof mounted for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61144	14041-10000-29661	936 S OLIVE ST	90015	14	127-5A209 193	5139004014	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/27/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Installation of new 875 device fire alarm system for a new 7 story apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61145	17041-10001-02523	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			Reviewed by Supervisor	02/13/2017 12:00:00 AM	ADDRESS	33.97808	-118.40726	PC FOR TEMPORARY POWER. SCOPE INCLUDES ADDING NEW DISTRIBUTION BOARDS, NEW PANELS, AND NEW CIRCUITS FOR A CONSTRUCTION SITE. PROJECT IS ON A METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61146	14041-10001-09842	3342 N VERDUGO ROAD	90065	1	153A215   288	5456001046	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/23/2015 12:00:00 AM	ADDRESS	34.11279	-118.23548	"Change to an approved set by revising the whole floor lighting plan. Energy plan check only.(((PLANCHECK FOR POWER AND ENERGY.  TENANT IMPROVEMENT TO RANCHO MARKET TO REPAIR INTERIOR PARTITIONS  DUE TO FIRE DAMAGES. EQUIPMENT RATED  OVER 600AMPS.""COMPLY WITH DEPARTMENT ORDER effective date08/13/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61147	15041-10000-13617	10155 N BALBOA BLVD	91325	12	204B133   337	2694019023	C2-1VL, P-1VL, RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.25543	-118.50255	SERVICE UPGRADE TO AN EXISTING SINGLE STORY COMMECIAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61148	11041-20000-20387	8158 W BEVERLY BLVD	90048	5	138B173   448	5511006031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.07591	-118.36736	PLAN CHECK POWER AND ENERGY FOR T. I. PATH LAB. NEW 600A SERVICE AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61149	11041-10000-10712	10924 W CHALON ROAD	90077	5	141B149   278	4369021014	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2011 12:00:00 AM			PC Info Complete	06/07/2011 12:00:00 AM	ADDRESS	34.0843	-118.45644	New 3 story single family home.  One of the floors is a basement.   everything is new.  600 amp service.  Full plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61150	14041-10000-28941	419 N ORANGE DR	90036	5	141B181  1425	5525030027	R2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.07894	-118.342	PV1, INSTALL 4.4 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(16) SOLARWORLD 275 MONO(1) INVERTER: SMA SB 3800-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61151	12041-10000-06288	1240 S NAOMI AVE	90021	14	121-5A213  54	5130006900	PF-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Expired	07/10/2018 12:00:00 AM	ADDRESS	34.02783	-118.24431	Plan check for 439.22KWdc roof and ground (canopy) mounted system.  The new 1600 A service, switchboard, and lighting plan check under #12041-10000-06291.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61152	15041-10000-01461	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM			PC Approved	01/16/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	T.I. to existing commercial space.  Total area = 493 sq. ft.New lighting and 1 new panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61153	13041-10000-34327	448 S HILL ST	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			Corrections Issued	12/10/2013 12:00:00 AM	ADDRESS	34.04896	-118.25139	Title 24 plan check  for elavator lobby and corridoor for a high rise building with total area 909 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61154	14041-20000-24761	5595 E HUNTINGTON DR NORTH	90032	14	147A239   267	5309024018	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.09542	-118.15833	TI IN AN EXISTING COMMERCIAL SPACE. T-24 ENERGY CALCS ONLY.PERMIT IS FOR NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61155	14041-20000-27488	155 W WASHINGTON BLVD	90015	14	123A207    74	5126028010	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.03191	-118.26615	Plan check for energy only. New building facade lighting on existing 13-story office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61156	19041-20000-51410	5261 E ALDAMA ST	90042	1	153A225   247	5469024016	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	09/29/2020 12:00:00 AM	PIN	34.11362958	-118.2022389	PV1. INSTALL 3.78 KW DC PV SYSTEM WITH (12) MODULES/OPTIMIZERS, (1) INVERTER (SE3800), AND (1) TESLA ENERGY STORAGE SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61157	18041-10000-24165	7769 N TOPANGA CANYON BLVD	91304	3	189B101   679	2012022016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.21186	-118.60619	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61158	16041-20000-45567	4550 N VAN NUYS BLVD SUITE D	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	TI to (E) retail store.  Plan check for energy.Building permit application filed under 16016-20000-31054.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61159	13041-20000-26639	5971 W VENICE BLVD	90034	10	126B173   912	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.03865	-118.37272	PC FOR T24 ENERGY ONLY. REPLACEMENT OF EXISTING FIXTURES FOR ENERGY EFFICIENT ONES. TOTAL AREA 40254 SQ FT. PC FOR CONTROLS AND FIXTURE CALCS. REDUCTION IN LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61160	16041-10000-10337	9315-9317 W PICO BLVD bldg A	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.05542	-118.39328	FULL PC for assembly load > 100.  Tenant improvement and alterations of existing synagogue, Building A, Scope of work includes new equipment, lighting for indoor and outdoor, and receptacles. Total sq. ft. 5758.Note: T-24 is 2013 per applicants request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61161	10041-10000-05691	16571 W VENTURA BLVD	91436	5	168B137   300	2259018022	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	05/27/2010 12:00:00 AM	ADDRESS	34.15798	-118.49405	REMODELING OF AN OFFICE DEPOT STOREPLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61162	18041-10000-24250	20929 W VENTURA BLVD 26	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	PLAN CHECK FOR POWER AND ENERG FOR FIRST TIME TENANT FOR Improvement to existing restaurant (from core and shell). TOTAL CONNECTED LOAD APPROX. 213A. TOTAL AFFECTED AREA = 947 SF. Unit 26 (This Project) is the First Tenant, subject to field inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61163	18041-10000-17108	6600 N TOPANGA CANYON BLVD Ste# 2110	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Issued	09/18/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TI FOR EXISTING RETAIL SPACE FOR NEW JOURNEY - TOTAL AFFECTED AREA = 1896 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61164	19041-20000-44911	2715 N JALMIA DR	90046	4	156B177   714	5570025038	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.11974	-118.36072	"NEW 800 AMP 120/240 SINGLE PHASE SERVICE, PANELS, AND EQUIPMENTS. NOTE:""New 2-stories accessory living quarter."" PER BUILDING."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61165	17041-10000-35365	250 N BURLINGTON AVE PV1	90026	13	136-5A207 263	5159009008	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Apartment			10/03/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.06744	-118.26543	PC for rooftop solar for apartment building. Installing 70 new PV modules with optimizer and one SE9.0KUS inverter. Total system size is 9kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61166	15041-20000-28031	1638 E VERNON AVE	90011	9	112-5A213  86	5106003025	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.00372	-118.24454	Plan check for a PV1 roof-mounted PV system. Systems size is 5 kWac and consists of (1) inverter, (24) modules, and (24) power optimizers. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61167	16041-10000-03762	6420 W WILSHIRE BLVD 4th fl	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.06365	-118.36922	T-24, TI TO THE 4TH FLOOR CORRIDOR. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1221..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61168	11041-10000-21470	3602 S LA BREA AVE	90016	10	120B177  1132	5046038023	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/21/2011 12:00:00 AM	ADDRESS	34.02129	-118.3554	T.I. to an existing McDonald's for outdoor and indoor lighting with Emergency lighting.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61169	15041-20000-20683	10815 N CANOGA AVE	91311	12	207B105   101	2722019034	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.26693	-118.59752	Plan check for PV roof mounted system. System size: 7.6kW with 1 inverter(7.6kW) and 26 modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61170	11041-10000-26396	863 N LUCILE AVE	90026	13	142-5A201 140	5427011003	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2011 12:00:00 AM	01/06/2012 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.08508	-118.28294	New 7.36KW rooftop photovoltaic system for a single family residence using Enphase M215 Micro-Inverters.   Variance to install M215 prior to Test Lab approval has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61171	19041-10000-25920	17535 W HORACE ST	91344	12	210B129   640	2712007028	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.26986	-118.51642	PV1. Install 11.4 kWDC AND 9.69KWAC roof mounted grid tied PV system. (40) modules with P320 OPTIMIZERS, (1) 11.4 KW (SE11400H-US) rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61172	16041-10000-08624	1317 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Expired	04/25/2018 12:00:00 AM	ADDRESS	33.78944	-118.24737	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER IN A 3 UNIT APARTMENT PER THE SINGLE LINE DIAGRAM. (8) MODULES AND (1) 2.0KW INVERTER. TOTAL SYSTEM SIZE IS 2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61173	16041-20001-27971	841 W 55TH ST	90037	9	108B197   685	5001007021	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	33.99244	-118.28851	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 125A MSP.4.9kW ungrounded system. (15) 327W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61174	14041-10000-26961	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	04/24/2015 12:00:00 AM	ADDRESS	34.05295	-118.25675	Energy plan check for full 27th and partial 26th floor in a high rise commercial building. submit under customer request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61175	16041-20001-36126	6612 N NESTLE AVE	91335	3	180B125   410	2125019009	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM			PC Approved	10/20/2016 12:00:00 AM	ADDRESS	34.19076	-118.53066	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system to an existing PV system. System addition size is 3 kWac and consists of (1) inverter, (9) modules, and (1) load center. Total system size is 6.8 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61176	13041-20000-13843	1515 N VERMONT AVE	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.09867	-118.29207	PLAN CHECK FOR MEDICAL OFFICE. REPLACING 2 COOLING TOWERS, 1 FILTER, AND 1 PUMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61177	14041-20000-12537	15760 W VENTURA BLVD Suite 1480	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/12/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.1552	-118.47684	PLAN CHECK FOR TITLE 24 ONLY COMMERCIAL OFFICE REMODEL .  NO NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61178	17041-20000-28491	4101 S REDWOOD AVE Bldg 6	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	33.99086	-118.44043	Plan check for power and energy. Project site is an tenant space is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 17,168 sq. ft.Note: Building application has been generated under 17016-10000-23000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61179	12041-20000-16160	750 S ALAMEDA ST	90021	14	123A215     9	5166031009	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.03162	-118.23863	Install indoor general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61180	17041-20000-24792	16509 W BLACKHAWK ST	91344	12	204B137   168	2679023013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.25848	-118.49178	pv1install roof mounted pv system 3.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61181	15041-20000-35840	607 E 115TH ST	90059	15	087A207   338	6072004027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	33.93021	-118.26477	TI, converting 1st floor storage room to an office. PC for Energy only, total area: 437 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61182	16041-20001-32230	23534 W HATTERAS ST	91367	3	174B093   126	2041009010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2016 12:00:00 AM			PC Approved	09/17/2016 12:00:00 AM	ADDRESS	34.17537	-118.63964	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61183	17041-20000-29865	11401 W CHALON ROAD	90049	5	144B145   221	4369007013	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.08803	-118.46305	new 800 amp service to an existing sfd.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61184	11041-20000-27208	255 S GRAND AVE # 110A	90012	9	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.05332	-118.25122	T24 plancheck for remodeled restaurant space 110A.  Install two new 120 volt circuits and 72 units on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61185	19041-20001-51471	3550 N GLENRIDGE DR	91423	4	159B157    64	2272029012	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			Reviewed by Supervisor	12/26/2019 12:00:00 AM	ADDRESS	34.13529	-118.43217	EXPEDITEDPV1. INSTALL 22.40 KW DC PV SYSTEM WITH (56) MODULES/OPTIMIZERS AND (2) INVERTERS(SE7600H-US)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61186	15041-10000-32369	300 WORLD WAY TERMINAL-3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	33.94502	-118.40714	T-24. PC FOR ENERGY ONLY. TI ON EXISTINC COMMERCIAL BUILDING (lAX TERMINAL 3). SCOPE INCLUDES NEW LIGHTING TO A NURSING ROOM. TOTAL AREA IS 71 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61187	18041-20001-44319	3717 N LONGRIDGE AVE	91423	4	162B161   646	2385008001	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.13829	-118.41838	PV1.  Install 23.04 kW DC grid tied roof mounted PV system.  (64) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61188	12041-20000-09671	7723 N KESTER AVE	91405	6	189B149   583	2209043021	M2-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Approved	04/27/2012 12:00:00 AM	ADDRESS	34.21099	-118.4576	"office t.i.Energy""Comply with Department order effective date 30 days from issuance date ""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61189	14041-20000-34873	11620 W WILSHIRE BLVD 11th floor	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/17/2023 12:00:00 AM	ADDRESS	34.05021	-118.45963	PC FOR T24 ENERGY ONLY. TI TO CORRIDOR AND ELEVATOR LOBBY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61190	13041-10000-14161	14114 W POLK ST	91342	7	225B153   221	2504019048	C2-1	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.31502	-118.44105	CONVERT (E) FIRST FLOOR OFFICE TO 2478 SF MEDICAL OFFICE ( 2ND FLOOR REMAIN AS GENERAL OFFICE, 2478 SF ),  ADDING NEW 104 SF 2-STORY LOBBY  & ADA LIFT AND RESTRIPING PARKING LOT  TO (E) 2-STORY OFFICE BLDG.  Existing main switchboard and DWP service, new dental office unit panel.  Power and energy plan check.  Healthcare facility as per NEC 517 definition.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61191	14041-20000-02094	1910 W 67TH ST	90047	8	102B193   485	6016020013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Expired	02/24/2016 12:00:00 AM	ADDRESS	33.9784	-118.31151	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan. ensure AFCI for DC protection at the inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61192	14041-20000-22210	24314 W KITTRIDGE ST	91307	12	180B089   422	2034018029	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.19046	-118.65561	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(24) KYOCERA KD255GX MODULES(1) SOLAR EGDE SE6000 INVERTER(24) SOLAR EDGE OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61193	16041-10001-09022	22139 W CANTLAY ST	91303	3	186B101   961	2023010020	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	34.20209	-118.60946	EXPEDITER PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.58kWdc / 7.095kWac.(33)MODULES-HANWHA Q PRO BFR-G4 (33)MICROINVERTERS-ENPHASE M215-60-2LL-S22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61194	16041-20001-30241	19538 W BLACKHAWK ST	91326	12	204B117   174	2708004003	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.25764	-118.55931	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 7 kWac and consists of (28) modules, (28) micro-inverters, (3) load centers, and (1) battery system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61195	16041-10000-00590	16933 W DEVONSHIRE ST	91344	12	204B133   147	2684012044	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.25767	-118.50128	T-24, TI TO AN (E) RETAIL SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1892	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61196	19041-20002-03805	15846 W NAPA ST	91343	12	192B141   100	2673009035	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM			PC Approved	08/09/2019 12:00:00 AM	ADDRESS	34.22642	-118.47802	07/09/2019 Changes to an approved set of plans. All changes have been clouded addition of 2 disconnects.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61197	14041-10001-33859	57 E MARKET ST	90291	11	108A143   429	4226007009	CM-1	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	33.98811	-118.47335	Expedited plan check per applicant request.  PV2.  Install 8.5 kW DC roof-mounted, utility-interactive PV system.  355 sq. ft. array.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61198	16041-10001-35381	1234 S PACIFIC AVE	90291	11	108A143   201	4238002900	OS-1XL	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM			PC Approved	11/10/2016 12:00:00 AM	ADDRESS	33.98992	-118.47385	PLAN CHECK FOR T24 ENERGY ONLY. NEW LIGHTING. PERMIT ALREADY OPENED UNDER MASTER APPLICATION. THIS APPLICATION IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61199	16041-20000-10983	13711 W FOOTHILL BLVD	91342	7	222B157    26	2509015025	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.30892	-118.4319	PLANCHECK FOR POWER AND ENERGY.  change of use from retail to medical office, urgent care and interior t.i. FEES PER APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61200	13041-20000-20948	2794 N WOODWARDIA DR	90077	5	156B153   176	4382025***	RE15-1-H-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.12278	-118.44512	PV1 TRANSFORMERLESS SYSTEM. 25 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 6.5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61201	14041-10000-07128	9127 N COLUMBUS AVE	91343	7	198B145   360	2656023035	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.23628	-118.46562	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN FOR CENTRAL TRANSFORMERLESS INVERTER.  SYSTEM SIZE: 4.75 KW.(19) CANADIAN SOLAR CS6P-250PX(1) POWERONE PVI 3.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61202	16041-20000-21186	10357 W DIAMOND ST LOT 3	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61203	19041-10000-46610	2301 N INVERNESS AVE	90027	4	153B197   416	5588034008	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			Ready to Issue	09/13/2021 12:00:00 AM	ADDRESS	34.11344	-118.28866	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 11.34KWdc (10KWac) USING 36 QP315 MODULES, SE P400 OTIMIZERS & SE-10000H-US INVERTERS. ESS TESLA POWERWALL.CONNECTED TO A 200 AMP EXISTING SERVICE.  Due to AB  1414 $0  permits fees.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61204	15041-10000-20545	3715 W SAN MARINO ST 1-19	90019	4	132B189  1117	5092022011	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.05453	-118.31375	PC FOR POWER AND ENERGY. NEW 4-STORY, 19 UNITS. TOTAL AREA 19760 SQ  UNCONDITIONED AND 675 SQ CONDITIONED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61205	19041-10000-15038	963 E 4TH ST 1st Floor	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.04337	-118.23442	Full plan check for Power and Energy, Change of use from retail to office space. Scope of work is being done on the 1st floor, New panels, circuits and new circuits to existing panels. . Total 1st floor area is 24,204 SF.Building P#:- 19016-40000-11268	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61206	18041-10000-17810	777 S SANTA FE AVE basement	90021	14	124-5A217 364	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	PLANCHECK FOR POWER AND ENERGY. Tenant Improvement at basement level.  17,648 SQFT.building permit # 17016-10000-38550	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61207	19041-10000-24829	6360 N CANOGA AVE	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM			PC Info Complete	07/17/2019 12:00:00 AM	ADDRESS	34.18619	-118.5972	Energy plan check for concierge lounge T.I. located on the 14th floor of a high rise building. Scope includes new lighting and equpment with a total lighting area of 1130-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61208	17041-20000-10661	8260 N HAVEN LANE	91325	6	192B133   532	2204001046	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.22086	-118.50722	pv1install roof mounted pv system sized 3.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61209	16041-20000-26183	2145 E SACRAMENTO ST	90021	14	123A217   222	5166005008	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.0307	-118.22836	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG.  TOTAL SQUARE FOOTAGE 5300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61210	11041-10000-19390	14651 W VENTURA BLVD	91403	5	166-5A149  38	2265005024	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.15174	-118.45268	TENANT IMPROVEMENT IN RETAIL SPACE FOR TJ MAX STORE PLAN CHK IS FOR TITLE 24 AND EM CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61211	17041-30000-10873	941 N HIGHLAND AVE	90038	4	144B185  1015	5532012041	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Issued	05/18/2017 12:00:00 AM	ADDRESS	34.08829	-118.33879	PC FOR TI IN RESTROOMS ON 1ST AND 2ND FLOORS IN A TWO STORY COMM. BUILDINGTOTAL AFFECTED AREA OF 740 SQ.FT. SCOPE INCLUDES NEW LIGHT, RECEPTACLES AND PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61212	13041-10000-36200	503 E 11TH ST	90015	14	124-5A211  54	5145019020	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.03645	-118.25381	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61213	15041-20000-30531	6310 W SAN VICENTE BLVD	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM			PC Approved	09/15/2015 12:00:00 AM	ADDRESS	34.06084	-118.36757	Plan check for Title 24 only in existing space. Total area: 7530 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61214	17041-10001-42324	11904 W TENNESSEE PL	90064	11	123B149   896	4259033002	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2017 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.03044	-118.44985	Void application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61215	11041-10000-03772	1610 S BARRACUDA ST	90731	15	021B209   220	7440022***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2961.00	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	04/01/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.73169	-118.26381	7000 SF  STATE APPROVED MODULAR OFFICE BUILDING ON EXISTING WHARF  @ PORT OF LA. VACANT LOT. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61216	14041-10000-03720	7900 S LOYOLA BLVD	90045	11	099B161     3	4113001004	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	33.96604	-118.41693	Installing a new medium voltage distribution switch to feed the future Bldg.,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61217	16041-20000-19912	823 W EXPOSITION BLVD ROOM 101	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.01842	-118.28748	PLANCHECK FOR POWER AND ENERGY. ASSEMBLY OCCUPANCY FOR USC HAR AV UPGRADE ROOM 101.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61218	16041-10000-13949	3377 W WILSHIRE BLVD A1	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM			PC Info Complete	04/21/2016 12:00:00 AM	ADDRESS	34.06193	-118.29742	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM A STORAGE SPACE TO A NEW RESTAURANT. SCOPE INCLUDES NEW LIGHTS RECEPTACLES. TOTAL AFFECTED AREA IS 1471 SQ. FT.* Permit issued under: 16041-10000-11058	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61219	19041-20000-34431	10945 W BLUFFSIDE DR	91604	2	162B173   267	2366021045	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	09/02/2022 12:00:00 AM	ADDRESS	34.14133	-118.36823	$0 fee per AB1414Plan check for PV roof mounted system, PV system size: 254.17KW DC, 216.3KW AC with 687 PV Modules and 5 inverters(SE43.2kw)One plan has 2 applications. 19041-20000-34431 and 19041-20000-34447	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61220	16041-20000-45443	5010 N PALOMAR DR	91356	3	171B117   547	2175004007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.16137	-118.55328	PV1.  Install 27.525 kW AC roof mounted grid tied PV system.  (95) modules with Enphase S280 microinverters.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61221	13041-10001-26322	18471-18477 W VENTURA BLVD	91356	3	171B125    25	2160008001	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.16876	-118.53553	chanhe of switch gear, two section s with 5 meters and one UGP. all existing loads and no load on 400 amps section .and new service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61222	11041-10000-03773	1139 S BEDFORD ST UNIT-1,-3,-4	90035	5	132B169   667	4332019013	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			02/28/2011 12:00:00 AM			Corrections Issued	05/19/2011 12:00:00 AM	ADDRESS	34.05595	-118.3806	INSTALLATION O+F A  PV SYSTEM TO SUPPLY POWER ON THE SUPPLY SIDES OF   CIRCUIT BREAKERS  FOR TFEEDERS TO  APARTMENTS PANELBOARDS. THE PV SYSTEM IS DIVIDED INTO THREE ARRAYS. PERMIT WAS OBTAINED OB 10041-10000-24004	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61223	11041-10001-18084	10149 N RESEDA BLVD	91324	12	204B125   215	2729011004	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM			PC Info Complete	08/17/2012 12:00:00 AM	ADDRESS	34.2554	-118.5364	(((((((  Changes made to the previously approved set  deleted the xfmr to reseda tenant  and instead got re-connected to 800 amps as bus tap.   8-17-2012  ))))))))))))))))))CHANGE OF USE FROM RETAIL TO DENTAL OFFICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61224	13041-10001-13464	14048 N SADDLE RIDGE ROAD	91342	7	231B141    44	2582030008	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.32588	-118.48252	(((changes to approved set of plans: REARRANGED PANEL PLACEMENT ON ROOF)))PV1.  6.048 kW DC solar array installation with 28 panels to be tied into 2-story house's existing main service panel.  {28 modules: REC 250 PE} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61225	17041-20002-14446	1302 S LA BREA AVE	90019	10	129B181   842	5070001018	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	34.04983	-118.34395	"10/5/2018changes to an approved set of plans.  changes noted delta 2 only.  changes to add 800 amp section to an existing distribution board ""MSA"" for EV chargers.((((Plan check for power and energy. Build out common areas (stairs, parking, etc.) for new 2-story commercial retail building over one level of subtarranean parking. 5,000A service. 107,978sqft indoor area, 30,644 outdoor area.))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61226	17041-20000-06932	5750 W WILSHIRE BLVD Floors-5 & 6	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is elevator lobby remodels to floors 5 and 6. Total lighting area = 555 sq. ft.Note: Building permit has been issued under 16016-10000-30610	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61227	13041-10000-12273	5757 W WILSHIRE BLVD Promenade	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Info Complete	07/03/2013 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for power and energy. TI to ambulatory (outpatient) surgical center at Museum Square.  Located on the Promenade Level. No plan check for OSHPD 3 requirments per applicant. Variance to separate fire alarm has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61228	15041-20000-28207	117 N LAS PALMAS AVE	90004	4	138B185   223	5513009016	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.0743	-118.33584	Plan check for power only. Project site is an existing single family dwelling. Project scope is service upgrade to 600 amps, (6) panels, associated loads, and (1) 15 kVA standby generator. Service is an underground service in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61229	18041-20000-06994	10856 N CARTWRIGHT DR	91311	12	210B113   257	2708030020	(Q)RA-1-H, (Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	02/12/2019 12:00:00 AM	ADDRESS	34.26832	-118.56615	installing (4) tesla power walls.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61230	17041-20001-01686	9742 N CACTUS AVE	91311	12	201B097    91	2724010016	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.24737	-118.62148	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61231	12041-10000-09052	901 W OLYMPIC BLVD	90015	9	129A207   293	5138005036	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	03/29/2013 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.04576	-118.26609	New fire alarm system for a 23 story hotel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61232	19041-10000-21512	5710 S CRESCENT PARK EAST	90094	11	102B157   265	4211020221	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/06/2019 12:00:00 AM	03/18/2020 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	33.9718	-118.42824	POWER AND ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT/ RENOVATION OF COMMON INDOOR AREAS WITHIN THE (E) MULTI-FAMILY-APARTMENT COMPLEX. SCOPE INCLUDES NEW 100A PANEL, EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 35266 SQ.FT ( NON-HIGH RISE)B#19016-10000-16998	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61233	08041-10005-15884	255 S HILL ST Bldg A,B,C	90012	9	130-5A211  15	5149010264	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Apartment			03/23/2011 12:00:00 AM	05/02/2011 12:00:00 AM		Permit Finaled	05/11/2011 12:00:00 AM	ADDRESS	34.05197	-118.24904	Chang the priviosly approved plan (provide as built plan). Add a teransformer, a panel and replace all EF  for three high rise apartments (Building A, B & C are under one building permit),  Plan check for Power.(((( THE 200 AMPS FUSE WAS REMOVED AND THE 150 AMPS FUSE WAS INSTALLED. 3-23-11))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61234	16041-20001-30321	6530 W SUNSET BLVD	90028	13	147A187   163	5547026024	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM			PC Approved	07/12/2017 12:00:00 AM	ADDRESS	34.09782	-118.3326	Revisions to approved plans.  Added emergency lighting inverter.  Minor power and lighting plan revisions.  Delta-1,6,7 revisions only.  (((Plan check for power and energy (power plan check requested by applicant). TI of existing Urm restaurant. New lighting (incl. emergency), restaurant equipment, receptacles, and panelboards. 4,901sqft. Permit already pulled under application #16041-20000-24743.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61235	16041-10000-05448	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.07157	-118.36014	TI TO RESTAURANT. PC FOR ASSEMBLY OCCUPANCY. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61236	16041-10003-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC AND PERMIT FOR ADDITIONAL SCOPE OF WORK. ADDED 3 OFFICES AND. ADDITIONAL POWER AND LIGHITNG INCLUDED. DELTA CHANGES NOTED DELTA DCN - 026	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61237	19041-20000-04659	1147 W 37TH ST 1-5	90007	8	120B197  1108	5040030016	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.0211	-118.29311	new apartment building service <400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61238	17041-10000-36261	1226 W SANTA CRUZ ST	90732	15	018B193   789	7452006015	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	33.74424	-118.3027	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING METAL HALIDE FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 24900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61239	12041-20000-26642	7080 W HOLLYWOOD BLVD	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.10134	-118.34445	RENOVATION OF (E) NIGHTCLUB, NO CHANGE OF USE.  Electrical plan check for assymbly area with more than 100 occupants.  T-24 and emergency lighting and power for the building.  Only change is to the lighting system.  The power system has no change. note : plan chk fee paid 11-15-12 on LA 03 17 350837  amt $266.66	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61240	15041-20000-18343	20508 W BERGAMO WAY	91326	12	210B109   419	2701050042	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.27624	-118.57946	Installation of new roof mounted solar PV array.  Total system size = 4.5 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61241	13041-10001-27862	1136 W FLORENCE AVE	90044	8	102B197  1211	6019011006	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	33.97444	-118.29512	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61242	14041-10003-21963	200 WORLD WAY Terminal 2	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	2/18/2015 Changes to an approved set of plans. All changes have been clouded and labeled as Delta 2. Changes include the change of the power rating for 3 fixtures, changes to the calculations of the Title 24 Compliance Forms, and adjustment to the connected load. 2/9/2015 Changes to an approved set of plans. All changes under this plan check have been clouded and labelled as Delta 1. Changes include changes to energy calculations (installed lighting has been reduced) and changes to the connected load (load has been increased). (((Revisions to approved set.  New sheet E106 for additional dry storage room (existing lighting to be reused per applicant).  Revisions to panel schedules on sheet E602.)))(((Plan check for power and lighting.  Total area = 3,921 sq. ft.T.I. to LAX terminal 2.  Installation of emergency lighting, recepticles, fire alarm system (11 notification devices), and panelboards (total connected load = 450 A))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61243	17041-10000-09731	1318 E 7TH ST SUITE 514	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.03608	-118.24052	"T-24, PC FOR ENERGY ONLY. INTERIOR T.I. TO EXISTING RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 546 SQ. FT. ""COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61244	17041-10000-23337	11401 N PORTER RANCH DR BLDG 8	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 41 unit apartment with 1600 amp 208 volt service.       Building 8 of 10.  Type IV.       Building permit #17010-10000-02385	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61245	19041-10000-28602	8447 N CANOGA AVE	91304	3	192B105   322	2779022078	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.22362	-118.5977	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61246	12041-10000-28669	9247 N VAN NUYS BLVD 1-56	91402	7	198B149   342	2651009003	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Apartment			11/29/2012 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.23862	-118.45064	New fire alarm system for a new four story apartment building (51 units). Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61247	11041-10000-12001	10880 W WILSHIRE BLVD 2090	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	06/10/2011 12:00:00 AM		Permit Finaled	07/28/2011 12:00:00 AM	ADDRESS	34.05885	-118.44283	TI IMPROVEMENT TO AN EXISTING 25-STORY OFFICE BUILDING.  T-24 PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61248	19041-10000-51819	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM			PC Info Complete	12/16/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 90 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61249	18041-20001-07141	5244 N LEGHORN AVE	91401	4	171B161   380	2345017082	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.16601	-118.41581	SUPPLEMENTAL TO EXPEDITE PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 15.2KVA CONSISTING OF 2 INVERTER(SE7600H-US) AND 55 PANELS WITH P400 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61250	10041-10001-07022	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***		Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM			PC Approved	12/12/2011 12:00:00 AM	ADDRESS	34.1504	-118.32742	Plan check for revision to approved plans. Change from #2/0 to #2 (15KV conductor) .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61251	14041-20000-17518	8588 N TELFAIR AVE	91352	6	192B169   163	2632015031	[T][Q]MR1-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Info Complete	06/27/2014 12:00:00 AM	ADDRESS	34.22586	-118.38537	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61252	18041-20000-26676	16633 W VENTURA BLVD Suite 1330	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for power and energy. Project site is a suite in an existing commercial high-rise building. Project scope is a change of use from office to medical office/tenant improvement. Total lighting area = 3,619 sq. ft.Note: Building application has been generated under 18016-20000-07452	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61253	19041-20000-16282	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	T24 ONLY PLAN CHECK TI REMODEL FOR NEW CORRIDOR LIGHTING AND OUTLETS ON EXISTING CIRCUITS AND FANS ONLY ON NEW CIRCUITS. TOTAL SQUARE FOOTAGE = 371SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61254	12041-10000-26852	8801 N SEPULVEDA BLVD	91343	6	195B145   378	2654013007	C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	11/20/2012 12:00:00 AM	ADDRESS	34.2301	-118.46786	Addition to an existing vehicle repair bay.  Load is less than 400amps per applicant.  PLAN CHECK ONLY for Energy, NO emergency lighting is part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61255	12041-20001-24869	21711 W VENTURA BLVD	91367	3	174B105    61	2168027032	(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.16908754	-118.60110998	Changes to approved set of plans. Delta 2 Changes only. Some clouded changes on power plan(s) are not reflected in panel schedule ex:) H-34 on E4.2Assisted living senior care (93.0206 (b) 3 and Article 517) . Full plan check and title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61256	12041-10000-10836	20638 W SCHOENBORN ST	91306	12	192B109   702	2780028029	(Q)RD3-1, R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.22088	-118.58329	Plan check for new installation of 6.867KW roof mounted photovoltaic system. single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61257	14041-10000-02190	331-335 S BROADWAY	90013	14	130-5A211 111	5149015018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			Verifications in Progress	06/30/2014 12:00:00 AM	ADDRESS	34.05037	-118.24893	VOID APPLICATION, NEW DESIGN SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61258	18041-10000-17429	1847 S CRENSHAW BLVD	90019	10	126B185   853	5071002024	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.04067	-118.33086	PC FOR A ROOF-MOUNTED PV ON A SINGLE FAMILY DWELLING. SCOPE INCLUDES 28 MODULES (CANADIAN SOLAR CS6K 300MS) , 28 MICRO-INVERTERS (ENPHASE IQ6PLUS-72-2-US) AND A COMBINER BOX. SYSTEM SIZE IS 8.12KWac AND 8.4KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61259	15041-10000-05423	9763 W SUFFOLK DR	90210	5	159B157   245	4385001026	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.12924	-118.42896	$0 PERMIT FEE IS DUE TO STATE SENATE BILL SB 1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(67) KYOCERA KD255GX MODULES(3) ABB INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61260	13041-10000-02144	13488 W MAXELLA AVE	90292	11	105B153    77	4212004032		West Los Angeles				2753.02	Electrical	Electrical	Apartment			01/28/2013 12:00:00 AM	03/26/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 11.88 KW DC.  42 MODULES IN 6 STRINGS. USING 3 INVERTERS (2 STRINGS PER INVERTER). [MODULE: ASP 283 W |||| INVERTER: AURORA # PVI-3.0-OUTD-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61261	17041-10000-24367	6600 N TOPANGA CANYON BLVD #48	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	01/17/2024 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR T24 ONLY. CONNECTED LOAD <400A. TOTAL AFFECTED AREA = 2253 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61262	16041-20000-09040	2011 S PONTIUS AVE	90025	5	126B153   508	4323024028	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.04227	-118.44061	Renovation of an existing 2-story office building.  No change of use.  Plan check for energy.  3285 sq ft RENOVATION OF AN EXISTING 2-STORY OFFICE BUILDING INCLUDING TWO ACCESSIBLE TOILET ROOMS; NO CHANGE OF USE, NO ADDITIONAL FLOOR AREA.  RESTRIPE (E) PARKING LOT.  Remove parking at front that is backing out on to street.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61263	17041-10000-00982	2216 S FEDERAL AVE	90064	11	123B153   255	4260015010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Info Complete	01/11/2017 12:00:00 AM	ADDRESS	34.03496	-118.44534	Plan check for Title 24 only in existing space T.I. for future tenant. Total area: 6,655 sq ft. Load less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61264	13041-20000-24078	10701 W SUNSET BLVD	90077	5	138B149   102	4362009007	A1-1XL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.07377	-118.44656	New Club house exercise room building.  Load is less than 400 amps, occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61265	18041-20000-00345	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is the first and second floor restrooms and corridors in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,756 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61266	16041-20000-32098	9344 W NIGHTINGALE DR	90069	4	150B169  1271	5561009037	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	34.10472	-118.39132	NEW SFD 600 AMP SERVICE.PLAN CHECK FOR POWER ONLY.PARTIAL ELECTRICAL PERMIT FEES PAID UNDER BUILDING APPLICATION NUMBER 15010-30000-01891. FEES HAVE BEEN ADJUSTED TO REFLECT THE REMAINING BALANCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61267	16041-20000-26270	14541 W HAMLIN ST	91411	6	180B149   576	2236015014	[Q]CR-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.18885	-118.45023	Plan check for Fire Alarm System in existing space. Total Fire Alarm Devices: 16 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61268	15041-10000-34098	201 N FIGUEROA ST 5TH FLOOR	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/14/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS, PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG. TOTAL SQUARE FOOTAGE 18338.  SCOPE OF WORK IN THE 5TH FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61269	18041-10000-23936	360 E 2ND ST 8TH FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	ENERGY PLAN CHECK FOR AN OFFICE TI LOCATED IN THE 8TH FLOOR OF A HIGH RISE BUILDING. SCOPE INCLUDE NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 12,077 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61270	11041-10000-22201	515 S FLOWER ST LEVEL D	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI TO AN EXISTING OFFICE SPACE.  PLAN CHECK IS FOR ENERGY ONLY.PERMIT FEE IS IN THE INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61271	14041-20000-04147	20800 W KINGSBURY ST PV1	91311	12	207B109   423	2706011011	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Expired	03/10/2016 12:00:00 AM	ADDRESS	34.26338	-118.58664	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PNL. UNGROUNDED SYSTEM, SIZED @ 4.75 kW DC, WITH (19) TRINA SOLAR #TSM-250PA05.18, (1) POWER-ONE #AURORA-PVI-4.2-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61272	16041-10000-09100	17383 W SUNSET BLVD A315-BLDG A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, PC FOR ENERGY ONLY. TI  FOR  AN EXISTING COMMERCIAL BUILDING AT SUITE A315. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SPACE AT SUITE A315. TOTAL AFFECTED AREA IS 1600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61273	14041-20000-09046	1948 N BERENDO ST	90027	4	150B197   632	5589026025	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.10677	-118.29384	PV1.  Install 2.59 kW AC roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.  Microinverter: Enphase M215-60-2LL.  12 modules: Solar World SW255-MONO	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61274	18041-10000-16557	4121 W SANTA MONICA BLVD	90029	13	145-5A201 370	5429002035	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	34.09205	-118.28241	PLANCHECK FOR POWER AND ENERGY. NEW 3 STORY MIXED USE BUILDING WITH 2 LEVELS OF PARKING.  41 UNIT APARTMENTS PLUS COMMERCIAL ON THE FIRST FLOOR.BUILDING PERMIT#  15010-10003-03531	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61275	10041-10001-00753	1884 E 22ND ST	90058	14	117A215     6	5167006021	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	03/11/2010 12:00:00 AM		Permit Finaled	04/14/2010 12:00:00 AM	ADDRESS	34.0169	-118.23653	Plan check for T-24 only as affects the location of switches.  Applicant indicates no changes to the installed lighting system other than switch locations.  See previous approved set of plans for T-24 calculations and installed lighting power..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61276	13041-20000-34014	4411 N LAUREL CANYON BLVD	91604	2	165B165   368	2364002022	[Q]C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	PIN	34.15064369	-118.39684616	T24 EXISTING RETAIL. 2297 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61277	13041-20000-28741	800 W OLYMPIC BLVD 5th floor	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.04484	-118.26453	T.I. to an existing high-rise office space.  No new loads per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61278	16041-10000-41832	644 N HOBART BLVD #1-12	90004	13	141B193   672	5521005005	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.083	-118.30564	FULL PC FOR POWER AND ENERGY FOR A 2 STORY 12 UNIT APARTMENT BUILDING. SCOPE INCLUDES 800A 120V/240 1PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 10038 SQ. FT. B#16010-20000-02793	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61279	15041-10001-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR CHANGES TO APPROVED SET OF PLANS. CHECKING FOR DELTA 1 AND 2 CHANGES. MAJORITY OF CHANGES INCLUDE ADDITIONAL EXIT SIGNAGE AND EGRESS IN PARKING GARAGE. REDUCTION OF EQUIPMENT SIZES ON SINGLE LINE. REVISED LAYOUT OF LIGHTING. UPDATED TITLE 24 FORMS. NO ADDITIONAL EQUIPMENT. PC ONLY. NO PERMIT NEEDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61280	17041-10000-40307	22350 W JAMES ALAN CIR	91311	12	204B101    88	2723008***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	34.25871	-118.61266	PLAN CHECK FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 6.03KWDC / 5.0KWAC (CENTRAL INVERTER)SCOPE INCLUDES 18 MODULES WITH CENTRAL INVERTER. CENTER FED VARIANCE HAS BEEN SUBMITTED WITH THE DEPARTMNET	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61281	19041-10000-01945	959 N SEWARD ST Unit 301	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.08878	-118.33338	PC T-24 ONLY FOR AN OFFICE IN THE 3RD FLOOR. OFFICE. 3120 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61282	14041-20000-08463	4858 N VAN NUYS BLVD	91403	4	169-5A151  96	2248006001	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	34.15928	-118.4485	permit to be pulled at EPC counter only. Plan check for energy only. TI TO (E) RETAIL. 1 STORY. LESS THAN 400A PER APPLICANT. emergency lighting required 2500SF/30SFoccupant is > 49.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61283	17041-20000-42581	24641 W STAGG ST	91304	12	189B089   300	2017027040	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.21256	-118.65721	PV1. Install roof mounted PV system sized 7.6 kW with battery back up interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61284	15041-20000-41267	10918 W BLOOMFIELD ST	91602	4	165B173   477	2423020006	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			12/08/2015 12:00:00 AM			Reviewed by Supervisor	12/30/2015 12:00:00 AM	ADDRESS	34.14918	-118.36849	PC FOR POWER AND ENERGY FOR A NEW TWO-STORY 9-UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61285	14041-10000-15584	5340 N CARTWRIGHT AVE	91601	2	171B177   177	2416027003	[T][Q]R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			06/11/2014 12:00:00 AM			Verifications in Progress	10/15/2014 12:00:00 AM	ADDRESS	34.16789	-118.36304	PC FOR POWER AND ENERGY. NEW 16 UNIT APARTMENT BUILDING. TOTAL AREA 1200 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61286	15041-10001-42022	763 W 110TH ST	90044	8	088-5A199 202	6075004004	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2016 12:00:00 AM			PC Approved	02/10/2016 12:00:00 AM	ADDRESS	33.9357	-118.28911	Chnage on approved set: change the orientation of rooftop modules. All other remain the same. Fee zero dollar per CA Senate Bill 1222. Permit under 15041-10000-42022<<PV1 INSTALL 6.75 KW D ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(25) MODULES: SUNEDISON (25) MICRO INVERTER:  ENPHASE M215-60-2LL-IG>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61287	14041-20000-29965	2585 S SEPULVEDA BLVD	90064	5	123B153   502	4256012009	R3-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Apartment			10/28/2014 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.03312	-118.43279	Plan check for power only. New 2-story 7-unit apartment building. 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61288	17041-10001-21917	4011 S CENTRAL AVE	90011	9	115-5A209 261	5114010017	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			Reviewed by Supervisor	03/30/2018 12:00:00 AM	ADDRESS	34.01063	-118.25682	Changes to an approved set of plans, Changes include the addition of load and outdoor lighting. Note changes on clouded areas. ____________________________PC FOR POWER AND ENERGY FOR  ADDITION TO (E) TWO STORY DRIVE-THROUGH  FASTFOOD RESTAURANT ( McDonalds). NEW SERVICE 1000A 120/208VTOTAL AFFECTED AREA 5097 SQ.FT. BL# 17014-10000-03112	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61289	14041-10001-12141	6511 N WHITSETT AVE	91606	2	180B165   548	2325016023	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.18897	-118.40555	(((EXPEDITE FEES)))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61290	11041-10000-15489	4225 S CENTRAL AVE	90011	9	114A209   153	5115019***	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	Apartment			07/28/2011 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.00695	-118.25669	T.I.  Historical Building.   On the first floor a new community room and four future tenant spaces..  On floors 3-5, rooms are to be converted to new apartments for seniors.Fire alarm plans  submitted on 11041-10000-15497	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61291	14041-20000-26398	5031 N DONNA AVE	91356	3	171B121   479	2176002002	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			Corrections Issued	10/29/2014 12:00:00 AM	ADDRESS	34.16248	-118.548	PV1.  Install 7.848 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61292	13041-10000-10833	3578 S MILITARY AVE	90034	11	117B161   325	4252016016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.01881	-118.41751	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. SYSTEM SIZE: 5.88 KW. TRANSFORMERLESS INVERTER. [INVERTER: AURORA PVI-6000-OUTD-US] [SOLAR MODULE: TRINA SOLAR TSM-245-PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61293	17041-30000-14898	2029 S CENTURY PARK EAST #2250	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing space office T.I. Total area: 2485 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61294	17041-10000-39647	16923 W VANOWEN ST	91406	6	183B133   917	2230010003	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.19408	-118.50178	INTERIOR TENANT IMPROVEMENT OF AN (E) RESTAURANT (29'x51') FOR A NEW WABA GRILL.PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61295	17041-10002-03338	5176 W SANTA MONICA BLVD 7	90029	13	144B193   729	5537019006	C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.09057	-118.30279	SUPPLEMENTAL FOR PC ONLY. THIS IS T24 PC FOR PERMITS ALREADY ISSUED. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61296	13041-10000-32334	5448 W HOLLYWOOD BLVD	90027	13	148-5A193 151	5544021910	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM	10/05/2016 12:00:00 AM		Issued	10/05/2016 12:00:00 AM	ADDRESS	34.10157	-118.30874	TI  for commercial part of a mixed used  building, total area 4664 sq ft.4 story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61297	17041-10000-19534	1338 N FORMOSA AVE	90046	4	147B181  1083	5548021035	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			06/20/2017 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.09551	-118.34613	NEW 25 UNIT APARTMENT. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61298	15041-10001-14577	1321 E PALMETTO ST	90013	14	126A217    38	5164003012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	ADDRESS	34.04034	-118.23199	03/14/16Changes to an approved set of plans. Changes include adding/replacing lighting fixtures with LEDS, and adding receptacles. (((TI-24 TO AN (E) COMMERCIAL BUILDING. NEWLY CONNECTED LOAD LESS THAN 400 AMP, PC FOR ENERGY ONLY. TOTAL SQ. FT. 6817	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61299	16041-10000-23969	6121 W SUNSET BLVD	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	Title 24 plan check only.  Installation of new lighting including emergency lights on 2nd, 3rd, and 6th floor terraces.  Three new branch circuits total (one for each floor).  All other electrical work to be under seperate permit.Building permit #15041-10000-04927	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61300	15041-20001-34603	10340-10378 N SEPULVEDA BLVD	91345	7	204B145   201	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.2586	-118.46705	"7/11/17changes to an approved set of plans.  reduction in panel 3EV.   changes clouded EV.  this is plan check only.6.27.2017 - Plan check for modifications to approved set. Changing feeders from copper to aluminum + delta J clouded changes ONLY. ""BLDG 3"".=======PC FOR POWER AND ENERGY.  NEW 3500A SERVICE. CHANGE OF USE FROM COMMERCIAL TO RESTURANT. PART OF THE JOB IS FOR SHELL. CAHSE BANK AS EXISTIN REMAINS. TOTAL AREA 3760 SQ FT(OUTDOOR LIGHTING) PLUS 696 SQ FT(INDOOR).B# 15018-10000-21181."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61301	17041-30000-33516	2049 S CENTURY PARK EAST 4th Floor-Lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 onl. in existing highrise elevator lobby 4th Floor. Total area: 295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61302	14041-10000-17334	11400 W OLYMPIC BLVD	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	07/14/2014 12:00:00 AM	ADDRESS	34.03666	-118.44346	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 12 FLOOR. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS PER APPLICANT. 11380 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61303	11041-20000-06740	1401 S SANTEE ST	90015	9	124-5A209 256	5133016002	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	08/08/2011 12:00:00 AM	ADDRESS	34.03412	-118.25933	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61304	14041-10000-33845	555 S FLOWER ST Suite 3200	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	Title 24 plan check only.  Total area = 4877 sq. ft.T.I. to existing commercial office highrise space including lighting, recepticles, and one new feeder.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61305	16041-20000-28681	14401 W SYLVAN ST	91401	6	178-5A151 121	2240002015	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.1848	-118.44665	SERVICE UPGRADE TO A COMMERCIAL BUILDING 400AMPS.  PLAN CHECK PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61306	16041-20002-11023	5727 W LA MIRADA AVE	90038	13	144B189   118	5536001017	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			04/12/2018 12:00:00 AM			PC Approved	04/12/2018 12:00:00 AM	ADDRESS	34.09387	-118.31452	"Supplemental for changes to wording of series rated combination between Eaton type ""FD"" breakers and downstream ""BAB"" breakers. Series breaker combination between MS1 and subpanels VCC, HM,HL1 and HP1 shall match series combination listed on manufacturers spec sheet as clouded on plans."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61307	18041-10000-40491	703 E MACHADO DR	90291	11	111B145   532	4240019033	R3-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.00177	-118.47099	PV1, NEW ROOFMOUNTED SOLAR SYSTEM USING CENTRAL INVERTER  AND TWO NEW AC STORAGE. (1) 5KW INVERTER, (16) MODULES AND (2) 5KWAC POWERWALLS    TOTAL SYSTEM SIZE 5KWAC/5.2KWDC AND 27.0 KWH ENERGY STORAGE SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61308	17041-10000-13825	1542 S CALADA ST	90023	14	117A227   116	5192003011	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.01466	-118.19784	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  210675 SQ FT. INDOOR/OUTDOR LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61309	12041-10000-06759	10377 W MCBROOM ST	91040	2	207B177   104	2528031014	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.26281	-118.35664	NEW ROOF MOUNTED 9.6KW PV SYSTEM ON A SINGLE FAMILY HOUSE USING TRANSFORMERLESS INVERTERS.  PANEL/SERVICE UPGRADE ARE NOT A PART OF PLAN CHECK.  PLAN CHECK ONLY FOR PHOTOVOLTAIC PORTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61310	17041-30000-11718	13710 W FOOTHILL BLVD 1-42	91342	7	222B153    63	2509014902	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	11/23/2022 12:00:00 AM	ADDRESS	34.30854	-118.43227	Plan check for new Fire alarm system for new appartment 42 units appartment building. Total Fire alarm devices: 97 abd 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61311	19041-20001-49471	2527 S BENTLEY AVE	90064	5	123B153   327	4256016028	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Expired	09/15/2023 12:00:00 AM	ADDRESS	34.03461	-118.43275	PV1. INSTALL 6.56 KW DC PV SYSTEM WITH (19) MODULES AND MICROINVERTERS.NOTE: PARTIAL INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-49471	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61312	18041-20000-28943	1906 S OVERLAND AVE 1-16	90025	5	129B157   583	4321008017	R3-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	04/21/2021 12:00:00 AM	ADDRESS	34.05011	-118.43148	Plan check for new fire alarm system for 16 units 4 story apartment building. Total number of devices: 92 and 1 FACP B#16010-20000-05146	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61313	16041-10000-11397	6710 N ETHEL AVE	91606	2	180B161   247	2326009015	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.1924	-118.41791	PV1 SFD TOTAL SYSTEM SIZE 6.7KW AC USING MICROINVERTER SYSTEM WITH ENPHASE M250. 28 IN TOTAL. INSTALLED ON ROOFTOP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61314	12041-20000-07896	8801 N SHIRLEY AVE	91324	12	195B117    65	2783025044	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/06/2012 12:00:00 AM			PC Approved	04/06/2012 12:00:00 AM	ADDRESS	34.23003	-118.55811	T.I. to existing building.  Install indoor general/energency light.  Plan check for energy only.Note: Permit issued under 12041-20000-07897	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61315	14041-20001-34923	891 S BRONSON AVE	90005	4	132B189   840	5092002019	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM			PC Approved	01/15/2015 12:00:00 AM	ADDRESS	34.05634	-118.3209	Expedited per customer request.PV1. Install roof mounted PV system on sfd and detached garage. Interconnected with 225 A msp. System size 8.6 kW.36 275W modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61316	16041-10001-05675	21500 W VICTORY BLVD	91367	3	180B105    57	2146005186	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.18793	-118.59894	Changes to approved set.  New receptacles and changes to lighting plan.FULL PC FOR A TI IN A RETAIL STORE, SCOPE OF WORK INCLUDES NEW LIGHTING  AND RECEPTACLES. TOTAL SQ. FT. 29982.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61317	14041-20000-05601	20501 W ROSCOE BLVD	91306	3	192B109   743	2780028075	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.22027	-118.58011	T24 FOR EXISTING OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61318	14041-20000-18679	17165 W LORILLARD ST	91344	12	213B133    39	2607004036	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.2844	-118.5071	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(33) TRINA SOLAR MODULES TSM-255(2) SOLAR EDGE INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61319	14041-10000-12285	1800 N NORTH MAIN ST	90031	14	135A219    12	5410015007	M3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			05/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.06621	-118.22039	PLAN CHECK FOR POWER ONLY. Hazardous location. New Booster compressor (HYC compressor, additional storage, and replacement of CNG dispensers. Bldg#14026-10-00273	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61320	12041-20000-28335	2317 S KELTON AVE	90064	5	126B157   873	4322009032	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.04076	-118.43193	PV-1. Plan check for PV system. Transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61321	17041-20000-28874	1209 S ABBOT KINNEY BLVD	90291	11	108B145  1099	4239022011	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	33.99154	-118.46902	*plan check and permit not required for this scope of work, building classification is SFD and service is <400A*Plan check for energy only. TI/addition/change of use from SFD to mixed use (commercial office on first floor, residential above). New lighting: indoor-1,031sqft; outdoor-2,000sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61322	14041-10000-00770	4872 W VENICE BLVD	90019	10	129B181  1268	5067006036	C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.10	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.0459	-118.34362	Title 24 plan check only for changes to lighting system per inspector request.  Original permit issued under 13041-10000-32986.Original permit work description:  (((REPLACE LIGHTING FIXTURES, INSTALL SIGN POWER AND WINDOW A/C OUTLET. )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61323	10041-10000-11089	800 W 6TH ST 2ND  FLR	90017	9	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.05011	-118.2577	INTERIOR REMODEL:  NEW MEN'S AND WOMEN'S ACCESSIBLE RESTROOMS  NEW ELEVATOR LOBBY ENCLOSURE, EXIT CORRIDOR FOR LOBBY, AND STAIR VESTIBULE. plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61324	14041-20000-25921	19100 W VENTURA BLVD Ste F	91356	3	174B121   460	2163021008	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.17237	-118.54897	Change of use from  (E) Retail tenant space to  (N) Yogurt Shop.  Plan check for 2013 Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61325	18041-10000-13234	3377 W WILSHIRE BLVD 205-208	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Issued	08/02/2018 12:00:00 AM	ADDRESS	34.06193	-118.29742	FULL PLAN CHECK FOR A CHANGE OF USE FROM MUSIC ENTERTAINMENT TO BASEBALL BATTING, DINING AND DRINKING AREA. A - OCCUPANCY > 100.  SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61326	19041-20000-10310	1813 S MESA ST LOT 14	90731	15	012B201   789	7456029040		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	33.72757	-118.28612	INSTALLATION OF A 3.02KW DC/2.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (9) SUNPOWER 335 BLK PV MODULES WITH INTEGRATED MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61327	12041-20000-06827	19249 W ROSCOE BLVD	91324	12	192B117   687	2784019007	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.22065	-118.55273	T-24 restaurant extension energy and emergency lighting. 1475 sqft. Plan check for power required due to change of use from retail to restaurant. Power Plan Check is on 12041-20000-06842.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61328	18041-20000-16477	14910 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29398	-118.45532	Plan check for PV roof mounted system, system size: 3.8kw with 12 modules and 1 inverter(3.8kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61329	14041-10001-01821	100 N LA CIENEGA BLVD	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	34.07466	-118.37629	Modifications to approved set.  Change of luminaires to match as-built design.  Updates to Title 24 calculations and fixture schedule (sheets E301 and E401).  (((pc for power and energy. new restaurant. clarify service14016-1000-01192)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61330	15041-10000-43432	17383 W SUNSET BLVD A300	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.03917	-118.55529	PC for energy only to an existing commercial building (offices) adding new lighting and receptacles. Sq ft = 1850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61331	16041-10000-31546	755 W CAPITOL DR	90731	15	024B197   409	7445001800	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	33.75875	-118.29459	PC for energy only upgrading service to 1200A  277 / 480V three phase 4wire, adding new equipment including a new compressor skid and new dryer control panel as noted on cloud delta 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61332	14041-20001-09441	2053 W VENICE BLVD	90006	10	126B193   221	5075013019	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	34.04374	-118.30174	Modifications to approved set.  Changes made to lighting plan layout and associated T24 forms.  (((T24 FOR EXISTING DOLLAR TREE GROCERY STORE. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400AMPS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61333	14041-20000-31588	10523 W ASHTON AVE	90024	5	135B157   496	4326003226	[Q]R3-1	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.0631	-118.43145	NEW FIRE ALARM SYSTEM FOR FOUR STORY APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61334	16041-10000-00653	5117 N LOLETA AVE	90041	14	162A227    77	5669012024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.13981	-118.19827	PV1, rooftop solar installation 3.8 kW AC interconnect with 225A MS(16) AXITEC: AC-310P/156-72S(1) SE3800A-USPower optimizer is used SE P-350	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61335	19041-10000-28999	1340 E 6TH ST 2ND FLR	90021	14	126A217   152	5164011001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Issued	07/26/2019 12:00:00 AM	ADDRESS	34.03813	-118.23423	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR A MANUFACTURING BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 16552 SQ. FT. B#18016-10000-02959	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61336	14041-10000-10138	8037 S HOLY CROSS PL	90045	11	099B161   819	4113007024	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	33.96469	-118.41588	PV1 4.32KWAC. 240V. microinverter. STD. 2story. Roofmount. [(20) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(20)modules: {QUASAR 260 CSUN 260-60M}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61337	14041-10001-01134	1505 E 1ST ST	90033	14	129A219    65	5173031902	[Q]M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.04761	-118.22376	(((5/22/2014- ADDED EXIT SIGNS TO APPROVED SET. PERMIT TO BE PULLED ON 14041-10001-01134)))Alteration to office space in one story building for City of Los Angeles.Total  area 600 sq ft. Plan check for T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61338	18041-20000-48547	1965 N CANYON DR	90068	4	150A191    24	5586023032	R1-1-HPOZ	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.10715	-118.31711	Installation of 13.5 kWh energy storage system and critical load panel interconnected with (E) 6.16 kW PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61339	12041-20000-00055	20621 W WELLS DR	91364	3	169-5A111 102	2166026014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2012 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.15767	-118.58222	New 10.11 KW roof mounted PV system for a single family residence. Besides the PV system, the main panel will also be upgraded to 225 A along with the main breaker being upgraded to 200 A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61340	11041-20000-10959	127 S SAN VICENTE BLVD Bulletin-67CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION bulletin # 67-cs	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61341	14041-10000-34827	8806 N AMIGO AVE	91324	12	195B125   557	2770015031	[T][Q]MR1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.23109	-118.53846	Plan check for title 24 only. Remove HID light fixture and replace with new LED fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61342	19041-10000-31132	3117 S RAYMOND AVE	90007	8	120B197   539	5040002025	[Q]R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.02604	-118.2982	NEW FIRE ALARM SYSTEM IN AN APARTMENT BULDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61343	17041-20000-36404	1200 W 7TH ST Ste 120	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.05136	-118.26616	Tenant improvement to (E) commercial office space in a highrise building.  Plan check for energy.Building permit issued under 17016-10000-26141	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61344	14041-10000-12447	8655 S SEPULVEDA BLVD	90045	11	096B165   768	4122001003	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.95844	-118.39645	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61345	17041-10004-01258	8151 N VENTURA CANYON AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM			PC Approved	04/02/2018 12:00:00 AM	ADDRESS	34.21934	-118.42889	PLAN CHECK ONLY FOR CHANGES TO SINGLE LINE DIAGRAM UNDER DELTA 10. CHANGE INCLUDES REMOVAL OF BAY-O-NET FUSE AND REPLACING IT WITH SURGE ARRESTOR FOR 2000KVA TRANSFORMER ONLY. CHNGING Plan check for power only, new Fuel Cell system rated at 1.6 MW. Fuel cell system is rated at 480 V conncected to 4.16KV (Medium Voltage) distribuition system OSHPD.  Installation on Keiser building connected exterior to OSHPD  4160 V medium voltage service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61346	11041-10000-24450	5328 S CENTRAL AVE	90011	9	108B209   495	5104014037	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM			PC Approved	11/15/2011 12:00:00 AM	ADDRESS	33.99405	-118.25628	T.I. to an existing Child Care Center.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61347	19041-20000-06813	9315 S LINCOLN BLVD PV1	90045	11	096B161   831	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	08/29/2020 12:00:00 AM	ADDRESS	33.95584	-118.41565	PV2.  Install 61.32 kW DC / 56.03 kW AC roof mounted grid tied PV system.  (168) modules with (2) 30 kW rated string inverters. System 2 of 4.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61348	17041-30000-01546	1900 S AVENUE OF THE STARS 320	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.05979	-118.41671	Title 24 plan check.  Partial floor T.I. on third floor of existing office building (suite 320).  Existing subpanels to feed new loads.  Total area = 3,420 sq. ft.  Building permit #16016-10000-26311	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61349	10041-20000-18733	8001 N CANOGA AVE	91304	3	189B105   158	2110020004	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.21606	-118.59777	Plan check T24 Energy for building TI. Permit for additional (5) ckts added to existing panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61350	15041-20003-36201	535 S KINGSLEY DR	90020	10	135B193   769	5503023019	P-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.06428	-118.30317	08/22/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 7. Indicated feeders were changes from raceway to MC cable and circuit breaker series-rating combination has changed manufacturers.4/19/2017 Changes to an approved set of plans.  Changes noted delta 5 and 6.  revisions include aluminum feeders and energy calculations. This is plan check only.  (((PC for power and energy on a New 7-story, 72 unit apartment building over a podium parking level and 1 level of subterrean parking garage.  total area is 72,755 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61351	19041-10000-06563	2316 E IMPERIAL HWY MENS-STRUCT.	90059	15	084B217    95	6150016***	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	33.92887	-118.23076	EMERGENCY HOMELESS SHELTER, SCOPE OF WORK INCLUDES PLAN CHECK FOR FEEDER TO MEN SLEEPING STRUCTURE. B#19010-10000-00750APP # 1 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61352	07041-10007-19016	751 N FAIRFAX AVE	90046		141B177   298	5527012031	(T)(Q)RAS4-1VL		Hollywood	Mid City West			Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM			Corrections Issued	02/03/2010 12:00:00 AM	ADDRESS	34.08526	-118.36177	Changes to previously approved plan s (E2).  New approval is for the removal of clouded area from scope of work.  Clouded area will be permitted at a future date.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61353	15041-20001-02007	1201 W 5TH ST SUITE 900	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.05429	-118.25967	"Changes to approved set.  Removal of one room from scope of work.  Title 24 sheets have been updated.*****Previous Work Description*****TI TO AN EXISTING OFFICE COMMERCIAL HIGH RISE BUILDING.  NEW LIGHTING NEW CONTROLS USING EXISTING PANELS.  SCOPE OF WORK TO BE PERFORMED IN SUITE 900.  TOTAL SQUARE FOOTAGE 5062.""COMPLY WITH DEPARTMENT ORDER effective date 01/26/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61354	15041-20000-10441	300 S GRAND AVE Suite 2800	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for title 24 only. Total area: 13130 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61355	14041-20000-27832	5736 N CASE AVE	91601	2	174B173   477	2337026019	RD1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.17501	-118.37182	PV1.  Install 4.59 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61356	14041-10000-27376	12121 W WILSHIRE BLVD #601	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	PIN	34.04391963	-118.46825257	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES IN HIGH RISE. NEWLY CONNECTED LOAD < 400 AMPS. 4500 SQFT, EMEREGENCY LIGHTING. UNIT 601	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61357	16041-20000-37233	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for Title 24 only. Project site is the production plating area within an existing industrial building. Project scope is lighting. Total lighting area is 1,342 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61358	15041-20000-28493	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.24143	-118.56249	Plan check for power and energy for T.I. work within existing space. Total indoor area: 4,536 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61359	17041-20000-00322	5200 W WILSHIRE BLVD R-14	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM			Corrections Issued	01/05/2017 12:00:00 AM	ADDRESS	34.06194	-118.3435	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a change of use from retail to coffee shop/tenant improvement. Total lighting area = 1,689 sq. ft.Note: Building application has been generated under 16016-10000-18966	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61360	14041-10000-26432	11823 W SHERMAN WAY 2C	91605	2	183B169    98	2317019026	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.20147	-118.39119	Title 24 plan check only.  Total area = 3372 sq. ft.  Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61361	14041-20000-29274	887 W 9TH ST	90731	15	015B197   860	7454008001	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM			PC Info Complete	11/04/2014 12:00:00 AM	ADDRESS	33.73594	-118.29652	TI TO AN EXISITNG SINGLE STORY MEDICAL FACILITY. PLAN CHECK FOR ENERGY AND POWER.2142 SQFTdue to building submittal, PC for 2008 building efficiency standardscomplete submittal fees have been collected under submittal-2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61362	19041-20001-41435	1630 N SAN PABLO ST	90033	14	135A225   143	5202001011	[T][Q]C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Approved	01/07/2020 12:00:00 AM	ADDRESS	34.06498	-118.20218	PV3 PLAN CHECK NEW ROOF PV SYSTEM ON EXISTING COMMERCIAL BUILDING. SYSTEM SIZE IS 36.225 KW DC/43.2 KW AC. SCOPE OF WORK CONSISTS OF (105) PV MODULES WITH 56 OPTIMIZERS AND (1) 43.2 KW INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61363	13041-10000-33138	20100 W VIA CELLINI	91326	12	219A115   344	2701039011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.2941	-118.57082	PV1, Install 8.75 kw DC roof-mounted solar array, interconnect with the service panel.(2)Transformerless inverter(s):Solaredge SE3000A-US and Solaredge SE5000A-US. (35)modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61364	16041-20000-07498	7607 N CARMENITA LANE	91304	12	186B089    26	2017028040	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	PIN	34.21004063	-118.65605571	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (47) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61365	18041-10000-18935	7500 N ALABAMA AVE	91303	3	186B105  1058	2111005034	[Q]R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.20675	-118.59884	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPESPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61366	17041-20000-36793	333 S HOPE ST 27TH FLR-PHASE 1	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Issued	11/16/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. 1263 SQFT. PHASE 1 OF 2BUILDING PERMIT # 17016-10000-29710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61367	16041-10000-00328	17158 W PARTHENIA ST	91325	12	195B133   458	2690015046	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Expired	02/05/2018 12:00:00 AM	ADDRESS	34.22839	-118.50776	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(48) REC SOLAR MODULES 275WATTS(48) SOLAREDGE POWER OPTIMIZERS(1) SOLAREDGE SE 11400 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61368	19041-10000-14237	4309 S LEIMERT BLVD Unit A	90008	10	114B185  1069	5024019013	C1.5-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.00526	-118.33016	PLAN CHECK FOR TITLE 24 ONLY FOR RESTAURANT. TOTAL EFFECTED AREA 625 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61369	17041-10000-02266	9650 N RESEDA BLVD	91324	12	201B125   307	2764006032	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.24607	-118.53588	PC for outdoor Tile 24 only. Remove HID fixtures and replace with new LED fixtures. Area: 90,700.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61370	18041-40000-03712	555 W 5TH ST #3380	90013	14	130-5A211 161	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 1819 SQ. FT. B#17016-20000-28646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61371	18041-10000-21660	8400 N BALBOA BLVD UNIT #105	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.22376	-118.50243	PLAN CHECK FOR TITLE 24 ONLY - CHANGE OF USE FROM (E) CORE AND SHELL RETAIL TO BEAUTY PARLOR (NAIL SALON) - TOTAL AFFECTED AREA 1250 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61372	17041-10002-16883	730 S SERRANO AVE 1-28	90005	10	132B193   438	5093014020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.05884	-118.30642	revision to an approved set Power check only. change under delta 2. change include updating load calculations(total and units) and updating the quantity of electric heaters and locations, less devices overall.permit fees under original applications.Building permit #17016-20000-02430	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61373	19041-20000-41883	6161 N SEPULVEDA BLVD	91411	6	177B145   612	2242001022	M1-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM			Verifications in Progress	01/08/2020 12:00:00 AM	ADDRESS	34.1821	-118.46652	TENANT IMPROVEMENT OF A TRAINING CENTER P.C FOR T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61374	14041-10000-28115	8207 W 3RD ST	90048	5	138B173   832	5511019025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.07262	-118.36835	PLAN CHECK FOR ENERGY ONLY FOR EXSTING RETAIL PLAN. PLAN CHECK UNDER 2008 CALIFORNIAN ENERGY CODE PER BUILDING SUBMITTAL. PERMIT PULLED UNDER APPLICATION#: 14041-10000-24003. NO ADDITIONAL PERMITS REQUIRED PER APPLICANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61375	16041-20001-10232	20600 W OAKSBORO CIR	91364	3	168A111    71	2174012027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM			PC Approved	04/08/2016 12:00:00 AM	ADDRESS	34.15477	-118.58204	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.4 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61376	19041-20003-13120	6040 W CENTER DR 1-218	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	33.97574	-118.39042	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO SINGLE LINE FEEDER INFORMATION, REMOVAL OF NEUTRAL FROM AC.3 AND ADDITION OF FEEDER AC.4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61377	16041-10000-41362	19625 W PARTHENIA ST	91324	12	195B117   172	2783025101	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.22843	-118.5603	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING TO MORE ENERGY EFFICIENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61378	10041-20000-24063	800 W OLYMPIC BLVD A215	90015	9	127-5A207 340	5138027***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.04484	-118.26453	relocate lighting energy plan check     A215 existing emergency lighting to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61379	14041-10000-26371	2430 N HOLLYRIDGE DR	90068	4	153A191   407	5586019056	R1-1	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.11239	-118.31962	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL STANDARD INVERTER PLAN. SYSTEM SIZE: 8.925 KW. (35) KYOCERA #KD255GX(1) ABB PV1 3.0 INVERTER(1) ABB PVI 3.6 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61380	14041-10000-27760	300 S GRAND AVE Suite 110	90013	14	130-5A211   8	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	PIN	34.05311046	-118.25061911	Title 24 plan check only.  Total area = 1,895 sq. ft.T.I. for new wine tasting store.  Change of occupancy (previously retail).  High rise building (42 stories).  New lighting and recepticles, existing panels.  Building application # 14016-10000-20341	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61381	15041-10000-22131	1801 E 41ST PL STE A	90058	9	114A213   137	5116029059	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.00713	-118.24109	REMOVE EXISTING HID LIGHITNG FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61382	13041-10000-03082	7301 N CANOGA AVE	91303	3	186B105   861	2111016038	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM			PC Approved	02/06/2013 12:00:00 AM	ADDRESS	34.20295	-118.59789	T24 FOR TENANT IMPROVEMENT, CATERING KITCHEN.  1 STORY BUILDING.  519 SQ FT KITCHEN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61383	18041-10000-10988	2435 S SEPULVEDA BLVD F/A	90064	5	123B153   158	4256010013	(T)(Q)C2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Public Safety Only			03/27/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM				NEW FIRE ALARM SYSTEM IN A NEW HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61384	17041-20001-10669	14921 W CALVERT ST	91411	6	178-5A149 316	2242024049	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.18133	-118.45821	08/22/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the distribution equipment in order to address the methane buffer zone requirements.*****Previous Work Description*****service upgrade to an existing commercial building 1200 amps with new panels.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61385	19041-20000-15989	13765 W VAN NUYS BLVD	91331	7	204B153   150	2618020013	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.25869	-118.43331	T24 PLAN CHECK ONLY FOR EXISTING COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES LIGHTS AND OUTLETS AND NEW PANELS AND AC UNITS. TOTAL SQUARE FOOTAGE = 4514SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61386	18041-10000-42835	11601 W WILSHIRE BLVD 16TH FLR	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR T-24  ENERGY ONLY FOR RESTOOM AND CORRIDOR TI IN A HIGH RISE BUILDIND ON THE 16TH FLOOR. TOTAL AFFECTED AREA 1684 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLESB#18016-10000-31079	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61387	15041-20004-31569	1457 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM			PC Approved	09/01/2017 12:00:00 AM	ADDRESS	34.09731	-118.31598	[[[9/1/17 changes to approved set. plan check only. delta 8 changes are clouded. minor title 24 changes and addition of closet with lighting and receptacles]]]]05/24/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Changes have been made to power disaggregation system and the recircuiting of the CFSDs, door power supplies, and window-washing receptacles.3/17/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 5 CHANGES HAVE BEEN UPDATED WITH FAULT CURRENT CALCULATIONS. ADDITIONAL CIRCUITS FOR UV LIGHTS HAVE BEEN ADDED. PANELBOADS HAVE BEEN UPDATED.02/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. There have been removal and relocation of electrical and mechanical equipment.*****Previous Work Description*****Plan check for power and energy. TI to existing  commercial building (5 floors). not a highrise per applicant.  Total sqft. 14,228.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61388	17041-10000-22047	221 S FIGUEROA ST	90012	14	133-5A211 255	5161006909	C4-2D, C4-4D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00, 2075.01	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM			Corrections Issued	04/16/2020 12:00:00 AM	ADDRESS	34.05628	-118.25373	This is not a real permit,for testing only - do not include in  statss.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61389	11041-10000-15615	5140 S CENTRAL AVE	90011	9	111A209   462	5104001032	C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Public Safety Only			07/26/2011 12:00:00 AM			Corrections Issued	07/30/2011 12:00:00 AM	ADDRESS	33.99615	-118.25625	New non-required 80 KW emergency generator for a 4-story senior housing building.  Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61390	10041-10000-06707	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM			PC Approved	04/13/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	TENANT IMPROVEMENT AT THE TOPANGA MALL- YOGURTSHOP BERICUPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61391	13041-10000-21439	11835 W OLYMPIC BLVD STE 1020-EAST BLDG	90025	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/09/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	PIN	34.03318579	-118.45141815	TENANT IMPROVEMENT FOR A HIGH-RISE BUILDING IN WESTSIDE TOWERS(EAST). TITLE-24 WORK FOR 3770 SF , ON 10TH FLOOR. EMERGENCY LIGHTING WILL ALSO BE INCLUDED IN THE SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61392	13041-20000-10039	4263 N EMPRESS AVE	91436	5	165B133   306	2292003006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.14856	-118.50265	Enphase system on roof of single family dwelling with PV subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61393	13041-10000-26378	1531 S DODSON AVE	90732	15	012B193   467	7560013023	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Expired	02/11/2016 12:00:00 AM	ADDRESS	33.72978	-118.31201	PV1 ROOF-MOUNTED INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE IS 8.25 KW DC ON standard plan IN A 2-story  HOME. combiner box IS UTILIZED.(33) MODULES: TRINASOLAR TSM-250PA05.18(1) INVERTER: FRONIUS #IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61394	18041-10000-33207	1700 S SANTA FE AVE	90021	14	120A217    21	5168001004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.02438	-118.22983	PLAN CHECK FOR FIRE ALARM SYSTEM FOR 1 FIRE ALARM PANEL AND 113 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61395	13041-10000-19886	1383 N MURCHISON ST	90033	14	132A227    19	5202011001	(T)(Q)C1-1VL	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.05771	-118.197	UPGRADE OF POWER TO 600 A; SHELL AND CORE ONLY WITH TITLE 24 FOR OUTDOORS. TENANT TO APPLY UNDER SEPARATE PLAN CHECK FOR TENANT IMPROVEMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61396	16041-10000-19866	1446 N NEPTUNE AVE	90744	15	036B205   929	7421027005	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.79231	-118.26969	Pv1, addition of 2.385 kw roof-mounted solar array  to an existing solar system (with 9 modules and one inverter) on a single family house.(9) modules: multiple modules(1) inverter: solaredge se3000A-us-zb-u	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61397	12041-10000-30909	746 S CENTRAL AVE	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/26/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.03537	-118.24198	"2 STORY PRODUCE MARKET T24""COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61398	17041-10000-23642	2105 E CESAR E CHAVEZ AVE	90033	14	129A223   105	5175014003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Info Complete	07/13/2017 12:00:00 AM	ADDRESS	34.04846	-118.21113	PC FOR TI TO A YOGURT SHOP FOR TITLE 24 ENERGY ONLY.INSTALLING NEW LIGHTS AND RECEPTACLES WITH NEW EQUIPMENT. TOTAL  AFFECTED AREA 783 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61399	15041-10000-07063	200 WORLD WAY # 282	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR ENERGY. INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM  ROW. TOTAL AREA 78.125 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61400	11041-10000-08285	3401 E WHITTIER BLVD	90023	14	121-5A227  87	5188004043	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	04/25/2011 12:00:00 AM	ADDRESS	34.0278	-118.20065	TITLE 24 PLAN CHK FOR A CANOPY FOR FUEL DISPENSERS. REFERENCE # 10041-10001-01884	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61401	19041-10000-11424	1019 E 4TH PL 4TH FLR	90013	14	127-5A217  60	5163018006	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.04195	-118.23327	PC FOR TI OF AN EXISTING 5 STORY OFFICE BLDG.TOTAL CONNECTED LOAD >400AFULL FLOOR BUILD OUT (4TH FLR)SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT, PANELS AND LIGHTS. TOTAL AFFECTED AREA 10600.NEW 2019 T24B#19016-10000-08850	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61402	19041-20000-39688	18560 W CALLE VISTA CIR	91326	12	213B125    93	2872020014	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.28329	-118.53809	PV1.  Install 5.44 kW roof mounted grid tied PV system and 9.8 kWh energy storage system.  (17) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61403	14041-20000-00578	22910 W VANOWEN ST	91307	12	180B097    24	2038040027	QC2-1VL	South Valley		West Hills		1352.01	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Closed	02/04/2014 12:00:00 AM	ADDRESS	34.19354	-118.62637	pc and permit for temp generator to power 1 service section during main service repair. 600kw generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61404	17041-20000-41047	9600 S SEPULVEDA BLVD	90045	11	093B165   137	4124025049	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Issued	12/05/2017 12:00:00 AM	ADDRESS	33.94841	-118.39594	Plan check for power only. Project site is an existing commercial building and parking lot. Project scope is a service upgrade to accomodate new electric vehicle chargers.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
61405	18041-10000-02493	1353 W 60TH PL	90044	9	105B197   439	6003017023	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.98513	-118.2998	PC for PV 7.6kW(AC) system for SFD with backup battery. Installing 21 modules (6.09kW DC) with 11 optimizers, new multimode inverter, and 5kW solaredge transformer. Battery installed is under permit 18041-10003-02493.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61406	19041-10000-04567	5830 W OBAMA BLVD	90016	10	120B173   562	4204020243	C4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.02154	-118.37378	NEW FIRE ALARM SYSTEM FOR EXISTING CORE AND SHELL COMMERCIAL BUILDING, SCOPE OF WORK INCLUDES (1) FACP AND (19) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61407	12041-10000-27762	3947 N VERDUGO VIEW DR PV1	90065	14	154-5A219 187	5472006041	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.1179	-118.22672	SUBMITTED AS A STANDARD MICROINVERTER PLAN BUT DUE TO ISSUE WITH TABLE 2 AMPACITIES, THEY DECIDED TO CHANGE FROM OVER THE COUNTER TO EXPEDITED REGULAR PLAN CHECKPV1 6.86KW ROOF-MOUNT ENPHASE MICROINVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61408	18041-10000-27692	2000 S STONER AVE	90025	11	123B149   154	4262031002	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.03641	-118.45099	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61409	16041-20000-28334	5229 N WILLOW CREST AVE	91601	2	171B177   510	2416028016	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			08/10/2016 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.16576	-118.3624	NEW 3 STORY 24 UNIT APARTMENT.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61410	10041-10009-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	05/20/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	RFI DRAWINGS AND PANEL SCHEDULES FOR BRANCH CIRCUIT CHANGES  AT THE BRADELY WEST CORE RENOVATIONS((((((((((Addition and alteration to the TBIT.  The Core.  Full electrical and energy.  Variance was filed to separate the electrical and fire life safety plan checks and permits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61411	12041-20000-13272	3709 S UNIVERSITY AVE	90089	9	117B197   224	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM			PC Approved	06/07/2012 12:00:00 AM	ADDRESS	34.01851	-118.28672	"T.I. to existing building (USC) on 1st floor of space ""WAH 104"" and Exhibit area.  Install general/emergency lighting.  Plan check for energy only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61412	12041-10000-07173	7605 N SAN FERNANDO ROAD	91505	2	186B177    88	2466034006	M2-1	North Valley		Sun Valley Area		1222.00	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	06/29/2012 12:00:00 AM		Permit Closed	01/14/2015 12:00:00 AM	ADDRESS	34.2095	-118.35539	PLAN CHECK NEW 1600A SERVICE, SWITCHBOARD, TRANSFORMERS, PANELS, EQUIPMENT, AND CKTS FOR EXISTING COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61413	18041-10000-03556	6221 W 96TH ST	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	33.94902	-118.39331	PC for T24 only for outdoor lighting for bus terminal at LAX. Total area is 700sqft. Installing new panel, lights, receptacles and equipment. B# 17016-10000-37004.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61414	14041-20000-29309	9959 W RANCHO CABALLO DR	91040	7	204B181   276	2543015076	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM			Reviewed by Supervisor	11/14/2014 12:00:00 AM	ADDRESS	34.25271	-118.34839	PV1Install roof-mounted solar array on SFD. Interconnect with MSP. System size: 6.45kW.30 EnPhase M215 microinverters. 30 250W pv modules. 2 strings (15+15).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61415	13041-10000-32023	1132-1134 S ABBOT KINNEY BLVD	90291	11	108B145  1168	4238003024	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Apartment			11/15/2013 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	33.99142	-118.46956	Plan chck for power and energy on the 1st floor of a 3-stories commercial building; plan review for the 2nd and 3rd floors shall be on separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61416	15041-10001-27586	22526 S HALLDALE AVE	90501	15	045B193   787	7347006***	[Q]RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	33.8213	-118.30137	Install rooftop solar system 1.075kW AC system. permit under 15041-90000-27586	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61417	14041-10000-13140	3280 N GLENDALE BLVD	90039	13	153B209   147	5436024001	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Apartment			05/16/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.11866	-118.25972	Ti for a one story restaurant. title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61418	16041-30000-28590	2049 S CENTURY PARK EAST 6th Floor-Lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Issued	11/03/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check Title 24 only in existing high-rise elevator lobby 6th Floor. Total area: 355 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61419	14041-20000-26698	22240 W RYAN RIDGE WAY	91367	3	174B101  1455	2146011044	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.17127	-118.61164	$0 permit fee due to senate bill 1222 from 2012PV1.  Install 19.25 kW DC roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61420	19041-20000-13123	4856 N LANKERSHIM BLVD	91601	2	168B173   265	2353019014	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.15921	-118.37097	Plan check for Title 24 Energy only for Tenant improvement  retail space. Total area: 1,428 sq ft.B#19016-20000-10425	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61421	13041-10000-30044	6382 W RIGGS PL	90045	11	102B165   123	4110012010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Expired	11/30/2015 12:00:00 AM	ADDRESS	33.97801	-118.39895	PV1, Install 8.48 kW DC roof-mounted photovoltaic system interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US, power optimizer, and 32 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61422	11041-10000-17820	6120 N LINDLEY AVE BLDG 5	91335	5	177B125   657	2123024025	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	34.1812	-118.52711	change of use from SFD to classroomsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61423	12041-10000-22660	2833 W 8TH ST	90005	1	132B197   414	5077019006	R4-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			09/24/2012 12:00:00 AM			PC Approved	09/24/2012 12:00:00 AM	ADDRESS	34.05786	-118.28774	TI IN HALLWAY OF A BOARDING HOME ON 2ND FLPLAN CHK IS FOR TITLE 24  FOR THE LIGHTING FIXTURES IN THE HALLWAY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61424	16041-20000-08862	8501 S SEPULVEDA BLVD	90045	11	096B165   278	4108019014	[Q]R3-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	33.96108	-118.39649	PV2.  Installation of 20.4 kW roof-mounted PV system on (E) apartment building.  (3) 6 kW inverters with (66) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61425	14041-20000-19999	10434 N DEBRA AVE	91344	12	207B137   887	2679016035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.26036	-118.4901	New roof mounted PV system with total system size 6.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61426	19041-20000-45063	12401 N MARVA AVE	91344	12	219B129   420	2608012001	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.29677	-118.5175	Plan checkf for PV roof mounted system, PV system size: 13.5KW AC, 15.6KW DC with 39 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61427	16041-20000-36929	14300 W SHERMAN WAY	91405	6	183B153   134	2217006061	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.20099	-118.44464	Plan check for Title 24 only. Project site is the parking lot of an existing building. Project scope is parking lot lighting. Total lighting area = 47,120 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61428	16041-20000-25299	8127 N VARNA AVE	91402	6	192B157   942	2301005039	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.21856	-118.4249	Plan check for PV roof mounted system. System size: 3kW with 12 modules with 1 inverter(3.0kW). Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61429	16041-20001-06953	1901 S FIGUEROA ST	90007	9	124-5A205 194	5126003016	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.0343	-118.27237	12/02/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1 and 2. Changes have been made to the way panelboards are fed and to loads throughout. *****Previous Work Description*****Plan check for power and energy. Project is located in methane zone. New 4 LEVEL PARKING STRUCTURE WITH A MOTOR VEHICLE REPAIR ON THE BASEMENT LEVEL. New 2000A service and distribution. Basement level is a hazardous area per article 511. 199,640sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61430	16041-10000-04043	15909 S ORCHARD AVE	90247	15	069B197   130	6120014020	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	33.88687	-118.28838	PV1, rooftop solar 6.0kW AC. Standard plan is used.(28)MODULES- KU2656ZPA(1)INVERTER- PVI-6000-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61431	18041-20000-32931	132 S LA BREA AVE	90036	5	138B181  1004	5513018008	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.07254	-118.34383	ti to an existing commercial space.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61432	13041-10000-11859	2629 N MANDEVILLE CANYON ROAD	90049	11	141B133    15	4492029003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.08584	-118.50385	PV1  HOMEOWNER-DESIGNED. 7KW ROOFMOUNT. NONSTandarD PLAN. (1) solaredge inverter: se-6000A-US. (28) REC solar REC250 PE (BLK) modules. 2 stories	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61433	19041-20000-15977	4220 N COLDWATER CANYON AVE	91604	2	165B161   920	2375021022	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	08/12/2022 12:00:00 AM	ADDRESS	34.14584	-118.41358	PLAN CHECK FOR NEW 5000A SERVICE, (4) PANELS OVER 1200A, (3) PANELS 601-1200A, (3) 0-200A PANELS, (1) EQUIPMENT 20.1-50 HP-KVA, (1) EQUIPMENT 5.1-20 HP-KVA, AND (20) BRANCH CIRCUITS.2 SEPERATE PERMITS T24 fee paid under 2nd permitTHIS PERMIT IS FROM B#18010-10000-048042ND PERMIT IS UNDERE#19041-20000-15948 AND IS FROM B#18010-10000-02992	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61434	18041-10001-02140	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	SUPPLEMENTAL FOR CHANGES TO APPROVED SET, ADDITION OF 1403 SQFT, AND 22 NEW BRANCH CIRCUITS, NEW TOTAL SQFT = 34683	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61435	17041-20001-36218	5325 S COMPTON AVE	90011	9	108B209   453	5104009030	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Apartment			10/10/2017 12:00:00 AM			PC Approved	11/20/2017 12:00:00 AM	ADDRESS	33.99414	-118.24792	EXPEDITED PER APPLICANTS REQUESTpv2install roof mounted pv system sized 3kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61436	19041-10000-44430	3377 W WILSHIRE BLVD #104	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.06193	-118.29742	TITLE 24 PLAN CHECK WITH NEW CIRCUIT LIGHTING AND CONTROLS. TOTAL AFFECTED AREA 1125 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61437	14041-20000-08873	16913 W SATICOY ST	91406	6	186B133   214	2203013015	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.20857	-118.50184	Change of occupancy to healthcare facility.  Previously massage parlor.  Rewiring of existing receptacle loads per Article 517 grounding requirements.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61438	12041-10000-02584	1901 S FIGUEROA ST	90007	9	124-5A205 194	5126003016	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	ADDRESS	34.0343	-118.27237	NEW 800 AMP SERVICE AND PANEL & CIRCUITS FOR OUTDOOR LIGHTING IN A METHANE ZONE.  <<<T-24  OLTG WAS COMPLETED 12041-10000-02507>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61439	19041-20000-02755	2733 N AQUA VERDE CIR	90077	5	156B141    91	4378031022	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.12201	-118.47257	Plan check for PV roof mounted system, system size: 16.95KW DC, 15.2KW AC,  with 42 PV Modules and 2 inverter(7.6KW)Fee $58.21 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61440	14041-20000-30883	1014 N VERMONT AVE	90029	13	144B197   848	5539003023	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM			PC Info Complete	02/13/2015 12:00:00 AM	ADDRESS	34.09027	-118.29148	PLAN CHECK FOR POWER AND ENERGY. MEDICAL CLINIC 1ST FLOOR. OSHPOD 3. VARIANCE HAS BEEN SUBMITTED TO ADD LOADS WITHOUT PROVIDING LOAD CALCS. METER READING WILL BE PROVIDED TO INSPECTOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61441	13041-20000-16446	11061 N GRANGER PL	91326	12	210B117   112	2718001011	RS-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.27149	-118.55434	PV1 STANDARD PLAN. TOTAL SYSTEM SIZE: 10.78 KW. 44 MODULES, 1 COMBINER, AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61442	11041-20000-20589	9444 W SIERRA MAR PL	90069	5	147B165   576	4392004017	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	ADDRESS	34.09556	-118.39524	New 19.04 KW solar system for a single family residence.  System is roof mounted.  Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61443	13041-20000-05287	10863 N RESEDA BLVD PV-1	91326	12	210B125   742	2717015004	RE11-1	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	03/18/2013 12:00:00 AM	ADDRESS	34.26819	-118.53641	PV-1. Standard plan for single family. 7.7kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61444	12041-10000-17554	5410 N SAN FERNANDO ROAD WEST	90039	4	165B201   258	5593005048	M2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.15046	-118.27445	Plan check for new fire alarm system for existing 2-story building. Golden Road Brewery: Chloe's Pub	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61445	12041-20000-26619	12058 N CREEKVIEW ROAD	91344	12	216B125   348	2601070003	RE20-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2012 12:00:00 AM	12/05/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.29134	-118.5293	PV-1. Plan check for PV system. 10.575kW DC. Micro inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61446	19041-10000-53757	10914 W KINROSS AVE	90024	5	132B149    98	4363023027	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM			PC Approved	12/30/2019 12:00:00 AM	ADDRESS	34.06029	-118.44606	Title 24 energy plan check. Scope of work includes new lighting. Total affective area: 3133 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61447	15041-20000-20665	9620 W VENICE BLVD	90232	5	120B165   941	4207001037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.02448	-118.39627	CHANGE OF USE TO FURNITURE STORE. PC FOR T24 ENERGY ONLY. NEW LIGHTING. PER BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS. CONSTRUCTION STILL IN PROGRESS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61448	15041-20001-00016	11940 W ROSCOE BLVD	91605	6	192B165   516	2310001021	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2015 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.22147	-118.39374	Expedite per customer request.PV1. Install roof mounted PV system sized 6.0 kW. Interconnected with main service pannel.(16) Sunpower SPR327NE Modules (1) Aurora PVI-6000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61449	19041-20000-22654	19432 W BLYTHE ST pv1	91335	3	189B117   452	2105012035	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.21475	-118.55703	pv1install roof mounted pv system sized 7.6KW AC interconnecte with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61450	16041-10000-34166	706 E DUCOMMUN ST	90012	14	130-5A217 264	5173016005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM			PC Info Complete	02/15/2017 12:00:00 AM	ADDRESS	34.05183	-118.23298	Full plan check for power and energy. CHANGE OF USE AND 2ND FLOOR  ADDITION WITHIN 1 STORY WAREHOUSE CONCRETE TILT UP BLDG. Scope includes 1000A 480/277 4wire 3 phase service, distribuition board and motor loads. Total affected area: 50,939.   BLDG. B#16014-10000-03106	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61451	16041-10000-30316	1501 N SOTO ST	90033	14	133-5A227   7	5202002022	[Q]C2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.06079	-118.19919	PC FOR ENERGY. OUTDOOR SIGN  LIGHTING  (EXTERNALLY ILLUMINATED) INCLUDE 70 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61452	13041-10000-25734	4806 N VINELAND AVE	91601	2	168B173   470	2421014004	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.15786	-118.37008	TENANT IMPROVEMENT FOR AN EXISTING RESTAURANT; TITLE-24 ONLY IN A SINGLE-STORY BUILDING. TOTAL OF 885 SF AREA.CRA WILL BE CLEARED UNDER THIS APP#. TITLE-24 ELECTRICAL PERMIT TO BE PULLED AT THE ELP COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61453	16041-20000-20199	8706 N STANSBURY AVE	91402	6	195B153  1026	2638009009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Expired	07/12/2018 12:00:00 AM	ADDRESS	34.22821	-118.44343	CHANGES TO AN APPROVED SET OF PLANS.  DERATING MAIN BREAKER AND ADDING MONITORING CIRCUIT.  PARTIAL PERMIT FEES PAID UNDER APPLICATION 16041-20000-15092.PV1. ROOFMOUNTED SOLAR SYSTEM.  AC MODULES SYSTEM. SYSTEM SIZE: 6.54 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61454	14041-10000-23476	6551 E PICKWICK ST	90042	14	156A233    12	5716008042	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/02/2014 12:00:00 AM	ADDRESS	34.12352	-118.17506	INSTALLATION OF NEW ROOF MOUNTED SOLAR PV SYSTEM.  TOTAL SYSTEM SIZE = 5 KwAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61455	16041-10000-11805	5611 N FIGUEROA ST	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.10937	-118.19392	NEW FIRE ALARM SYSTEM 59 DEVICES WITH 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61456	15041-20001-29365	5625 W IMPERIAL HWY 2ND FLR	90045	11	087B169     1	4129028900		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM			PC Approved	11/25/2015 12:00:00 AM	ADDRESS	33.93197	-118.382	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING ON THE 2ND FLOOR (OFFICE  SPACE). SCOPE INCLUDES RELOCATING LIGHTINGS AND NEW RECEPTACLES AND DATA. TOTAL AREA IS 1957 SQ. FT. PERMIT PAID UNDER PCIS#15041-30000-29365	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61457	10041-20000-11407	8614 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM			PC Approved	06/15/2010 12:00:00 AM	ADDRESS	34.07598	-118.37831	OUTDOOR LIGHTING FOR PARKING VALLEY AREA. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61458	12041-10001-27906	10840 W NATIONAL BLVD	90034	5	123B157  1152	4254008003	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	06/28/2013 12:00:00 AM	PIN	34.02994066	-118.42137081	Changes from previously approved plans.  Changes in relocated and added indoor lighting.  Plan check for energy only.*****INTERIOR TI FOR CHASE BANK IN AN EXISTING ONE STORY BUILDING. REPLACE PORTION OF STOREFRONT WITH NEW. NEW EXTERIOR WALL OPENINGS(2), EXTERIOR WALK-UP ATM ABD (1) PACKAGE RECEIVER (NIGHT DROP).*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61459	17041-20000-00699	14533 W NORDHOFF ST	91402	6	198B149   556	2639008023	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	01/10/2017 12:00:00 AM		Issued	01/10/2017 12:00:00 AM	ADDRESS	34.23555	-118.44912	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is change of use from tint/stereo shop to restaurant/tenant improvement. Total lighting area = 626 sq. ft.Note: Building permit has been pulled under 16016-20000-08750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61460	15041-20000-30825	6301 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.18467	-118.60176	TENANT IMPROVEMENT OF CHANGE OF USE.  OFFICE SPACE 20,306 S.F.- 11TH FLOOR.  (N) DINING AREA 10,434 S.F. - 1ST FLOOR.pc for power and energy. energy plan check completed under separe application for 11th floor	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61461	19041-20000-16682	22135 W ROSCOE BLVD LOT #40	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	Plan check for PV roof mounted system, system size: 2.1KW with 7 PV Modules and 7 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61462	11041-20000-13298	11601 W WILSHIRE BLVD	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	08/05/2011 12:00:00 AM	PIN	34.0509267	-118.45996763	Ti in an existing office. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61463	13041-10000-34359	2717 N LAUREL CANYON BLVD	90046	4	156B173   638	5565038004	RE15-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.12005	-118.37539	PV1, install 2.5 kw DC roof-mounted photovoltaic system interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. , power optimizer, (10) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61464	16041-20000-00056	4151 W PROSPECT AVE 2ND FLOOR-BLDG E	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	02/10/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT TO OFFICES.  2ND FLOOR.  BLDG E. 1772 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61465	19041-10000-53238	6409 W SUNSET BLVD	90028	13	147A187   135	5546012011	(T)(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			Corrections Issued	02/06/2020 12:00:00 AM	ADDRESS	34.09815	-118.32905	(Fee Estimate)Full plan check for new hotel, 4000A, 4.16KV, 3ph,4w service, area of scope 227,917SF.**** 100% PDPP TO CHECK FOR GREEN, ADA, LIFE & SAFETY, AND STRUCTURAL ****NEW 19-STORY TYPE 1-A HOTEL WITH 4 LEVEL OF SUBTERRANEAN PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61466	13041-20000-16362	1441 W OLYMPIC BLVD	90015	1	129A205   148	5137005021	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.04841	-118.27203	RENOVATION OF EXISTING OFFICES FOR NEW BOOK STORE. PC FOR T24 ENERGY ONLY. TOTAL AREA 1832 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61467	16041-20001-16023	8422 N MCNULTY AVE	91306	3	192B109   454	2780004071	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.2228	-118.58704	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM 6KW INTERCONNECTED WITH MSP.(8) KYOCERA MODULES(2) 3.0KW INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61468	11041-10000-27129	968 N SOMERA ROAD	90077	5	144B149   325	4369033014	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2011 12:00:00 AM			Reviewed by Supervisor	02/24/2012 12:00:00 AM	ADDRESS	34.0879	-118.45678	New PV system for a single family home. EPC is for power	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61469	15041-10000-31918	111 E UNIVERSAL HOLLYWOOD DR STE 1950	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.13855	-118.36112	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  SUITE 1950.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61470	13041-10000-14477	6081 W CENTER DR 113-119	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	33.97811	-118.39245	Change of use of Howard Hughes Promenade space from retail (bookstore) to A2 and A3 occupancy (restaurant and arcade/amusement - Dave and Buster's).  New unit distribution system fed from existing service and main switchboard.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61471	10041-10000-23772	7765 N KESTER AVE	91405	6	189B149   556	2209043033	MR2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Public Safety Only			11/30/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	ADDRESS	34.21174	-118.45784	INSTALLATION OF A FIRE WARNING SYSTEM TO PROVIDE CENTRAL STATION MONITORING OF SPRINKLER AND HVAC SYSTEM IN A COMMERCIAL BLDG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61472	12041-10000-00738	17056 W GRESHAM ST	91325	12	195B133   401	2690010012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2012 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	03/06/2012 12:00:00 AM	ADDRESS	34.2296	-118.50465	New rooftop photovoltaic systems, for a single family residence.  8.5kw with two inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61473	18041-30001-39861	801 S FIGUEROA ST Lobby	90017	14			C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	01/15/2019 Changes to an approved set of plans. Lighting control details have been changed to reflect controls installed on field. *****Original Work Description*****Plan check for Title 24 only for T.I. in existing space lobby common area. Total area: 4255 sq ft. B#18016-10000-15002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61474	19041-30001-20322	100 N WOODBURN DR	90049	11	135B145    22	4429028039	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.07001	-118.4699	Change to an approved set under delta 1 , change includes changing the main to 400A from 200A, showing house load . and termination note.original:PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM. SYSTEM SIZE IS 21.9KW DC/15.2KW AC. SCOPE OF WORK INCLUDES (60) LG ELECTRONICS PV MODULES WITH SOLAR EDGE P320 OPTIMIZERS, A 100A LOAD CENTER, AND (2) SE7600H-US INVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61475	17041-10000-05472	13592 W DESMOND ST	91331	7	210B157   146	2523005024	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.27448	-118.42837	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR+ INDOOR) 73200 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61476	14041-10000-27325	10520 W CROCKETT ST	91352	2	192B177   810	2407004008	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Expired	10/27/2016 12:00:00 AM	ADDRESS	34.22002	-118.36029	PV1 Standard Plan, 6KW roof-mounted system including:  (1) Solardege SE6000A inverter, (26) Kyocera KD255 modules and Solaredge P300 Power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61477	15041-10000-01499	741 S AVENUE 61	90042	14	150A233   120	5312024080	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/21/2015 12:00:00 AM	ADDRESS	34.10538	-118.17928	Plan check for PV 1 roof mounted. 6.88 kW system with 27 modules.Reason for submit over the counter: Unable to pull permit online. 3 strings combined to 2. Online system does not accomodate this.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61478	15041-10001-34685	603 N ST LOUIS ST	90033	14	130-5A223 353	5175027001	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.05069	-118.21025	Expedited plan check.  \PV1.  Installation of 3.445 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61479	18041-20000-07785	4927 N EAGLE ROCK BLVD	90041	14	160-5A221  36	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.13588	-118.21531	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office and a tenant improvement. Total lighting area = 1,217 sq. ft.Note: Building application has been generated under 18016-20000-06495	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61480	13041-10000-33084	8500 N LOUISE AVE	91325	12	192B133    91	2690015030	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.2253	-118.50967	PV1.  Install 2.94 kW roof-mounted PV system, interconnect with main service panel.  12 modules: YingLi YL245P-29b.  Transformerless inverter: SolarEdge SE3000A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61481	14041-10000-01817	927 N ORANGE DR	90038	4	144B181   716	5532010051	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.08796	-118.34173	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 13870 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61482	14041-10000-29382	2716 W OLYMPIC BLVD Ste 202	90006	10	129B197   223	5078010028	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.05243	-118.29218	Title 24 plan check only. TI to existing barber shop tenant space. 210 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61483	13041-10000-25186	8311 W BEVERLY BLVD	90048	5	138B173   397	5514009026	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/12/2013 12:00:00 AM	ADDRESS	34.07623	-118.37043	"permit to be pulled at EPC Counter only. PC FOR ENERGY.TI (remodeling) TO (E) RETAIL (DEKOR HAUS USA). 2 STORY.  EMERGENCY LIGHTING to be same circuit as general lighting.""COMPLY WITH DEPARTMENT ORDER effective date07/09/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  CEIS Case Number is 504729.(Created: IMSV7 / 07-10-13)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 114672  -- Building/Electrical/MechanicalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issued with effective date 07/09/2013 by Inspector JOHN MATTILLO at phone# (213)252-3035.  CEIS Case Number is 504729.Payment of investigation fee due at time of permit issuance.NOTE: Investigation fee is minimum $400.00 or double the permit fee which ever is greater."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61484	13041-10000-03382	601 S FIGUEROA ST	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM			PC Approved	03/22/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	RECONSTRUCTION OF OFFICE SPACE. PC FOR T24 ONLY. TOTAL AREA OF 1914 SQ FT. WORK DONE ON 1ST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61485	15041-20001-22176	17332 W DEARBORN ST	91325	12	198B129   388	2766012010	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM			PC Approved	07/28/2015 12:00:00 AM	ADDRESS	34.23693	-118.51275	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 11KW AC USING 46 MICROINVERTERS. USING ENPHASE M250. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61486	15041-20001-14030	13291 N RALSTON AVE	91342	7	225B141   166	2501002023	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM			PC Approved	02/26/2016 12:00:00 AM	ADDRESS	34.31344	-118.47393	2.26.2016 - Plan check for modifications to approved set. Add 2,500A distribution board MSB2 located on interior wall of warehouse. Relocate loads from MSA to MSB2. Delta G changes. ---Plan check for power only. Project site is an existing commercial building. Project scope is the installation of a 4000-amp main service board with (4) sections, (1) 1600-amp distribution board, and (1) 900 kVA generator. Loads on the main service board are all future.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61487	18041-20000-45262	2055 W ESCARPA DR	90041	14	159A223    82	5685023018	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.13114	-118.21121	Plan check for a PV1 roof-mounted PV system. System size is 11.22 kWdc/10 kWac and consists of (1) inverter and (34) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61488	18041-20000-19847	17417 W PARTHENIA ST	91325	12	195B129   420	2768015035	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Issued	07/06/2018 12:00:00 AM	ADDRESS	34.22873	-118.51399	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM CONSISTING OF 16.4KVA SYSTEM (EXISTING 5.0KVA SYSTEM AND NEW 11.4KVA SYSTEM) - NEW SYSTEM 1 CENTRAL INVERTER (SE11400A-US) WITH 40 MODULES(P370 OPTIMIZERS).$45.83 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61489	15041-10002-01354	200 WORLD WAY TERM 2-ARRI LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/23/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	changes to approved set by ADDITION OF 125w INVERTER for emergency lights AND METERING. changes under delta 4. eSavvy space 283.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61490	12041-10000-02114	5601 N DE SOTO AVE Room 0904B	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM			PC Info Complete	01/27/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	"TI IN AN EXISTING OFFICE AREA OF KAISER BUILDING IN THE BASEMENT AREA IN ""ROOM 0904B"". PLAN CHECK FOR T-24 ENERGY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61491	14041-10000-04967	26220 S ATHENA AVE	90710	15	033B193   524	7411018013	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	33.78457	-118.30485	PV1, INSTALL 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(17) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61492	17041-20001-15050	7341 W FOOTHILL BLVD	91042	7	202-5A199  94	2568010004	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.25075	-118.29184	Plan check for fire alarm system per inspection correction notice.  (((INSTALL MONITOR FOR SPRINKLER)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61493	19041-20000-41698	8744 N REMMET AVE	91304	3	195B105   184	2779041034	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.22948	-118.60011	New 600A 240V 3ph-3w subpanel to re-feed existing loads only.  Ground fault detector added to (E) 600A ungrounded service.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61494	14041-10000-07103	1654 E 113TH ST	90059	15	087A213   331	6069023028	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	33.93187	-118.24413	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN FOR CENTRAL TRANSFORMERLESS INVERTER.  SYSTEM SIZE: 3.5 KW.(14) CANADIAN SOLAR CS6P-250PX(1) POWERONE PVI 3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61495	17041-20000-24776	8500 N BALBOA BLVD SUITE #170	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area of 96,648 sq. ft.Note: Building application has been generated under 17016-10000-15426	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61496	16041-20001-40166	6701 N RUDNICK AVE	91303	3	180B101   217	2139009022	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.19186	-118.61259	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (3) inverters, (51) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61497	16041-10000-31676	1048-1050 N MANZANITA ST	90029	13	145-5A201 413	5427006028	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Apartment			09/07/2016 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.0918	-118.2818	9 UNIT APARTMENT. PC FOR POWER AND ENERGY. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61498	18041-10001-26484	10277 W OLYMPIC BLVD	90067	5	129B161    44	4319005070	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.05329	-118.41657	Revision to approved set, added 4 devices. Voltage drop and battery calculation are revised accordingly.<<Plan check for a fire alarm system replacement. New device also added. Whole system include (1) fire alarm panel, (2) power supply and (29) new fire alarm devices.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61499	19041-20000-53873	8255 N BEVERLY BLVD	90048	11	126B149   238	4261019011	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM			PC Info Complete	12/31/2019 12:00:00 AM	PIN	34.04414816	-118.44612916	Distribution, power, and lighting for commercial tenant space improvements.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61500	12041-20000-22589	19727 W RINALDI ST	91326	12	210B117   380	2701040039	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			Corrections Issued	09/21/2012 12:00:00 AM	ADDRESS	34.27504	-118.56356	T-24 lighting plan check for remodeled existing space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61501	18041-10000-33412	1975 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.06159	-118.20463	PLAN CHECK FOR TITLE 24 ONLY FOR INSTALLATION OF NEW LIGHTING ONLY IN OFFICE SPACES WITHIN HIGHRISE BUILDING - TOTAL AFFECTED AREA = 1220 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61502	16041-10001-37979	555 W 5TH ST 3310	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	01/19/17CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE REVISING FLOOR LAYOUT FOR NEW PRIVATE OFFICES, REPLACING/ADDING LIGHTING FIXTURES, AND ADDING RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61503	19041-20001-29198	7362 N BOTHWELL ROAD	91335	3	186B117   626	2116003040	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	34.20459	-118.56079	Expedited plan check fee.PV1.  Install 8.19 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (26) modules with 7.6 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61504	14041-10001-32432	200 WORLD WAY # 231	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/27/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	((((5/27/2015)))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES MARKED DELTA 3.  CHANGES INCLUDE REVISIONS TO THE LIGHTING FIXTURES AND ENERGY CALCS.  PC FOR POWER AND ENERGY. TERMINAL 2 STORAGE, REVISING SOME LIGHTING AND ADDING SOME REFRIGERATION EQUIPMENTS AND SMALL OFFICE.(000) TOTAL AREA 215 SQ FT.PLAN CHECKER TO VERIFY THE FEE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61505	18041-10000-37985	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Issued	10/04/2018 12:00:00 AM	ADDRESS	34.09783	-118.36466	Modifying existing light fixtures to LED using UL Listed Retrofit Kits. T-24 Energy Only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61506	18041-30000-37869	10866 W WILSHIRE BLVD 1560-1570	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM			PC Approved	10/04/2018 12:00:00 AM	ADDRESS	34.05907	-118.442	PC FOR TITLE 24  ENERGY ONLY FOR OFFICE TI IN A HIGH RISE. SCOPE INCLUDES NEW LIGHTS TOTAL AREA  5310 SQ.FTTHIS PLAN CHECK ONLY!PERMIT PULLED UNDER 18041-10000-34291B#18016-10000-25289	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61507	19041-20002-28663	22720 W MARTHA ST pv1	91367	3	174B097   501	2040011026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.17265	-118.62192	09-11-2019 Changes to an approved set of plan PV, changes include revised critical loads. All Changes has been clouded. Plan check only.Fess $0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61508	15041-10000-31808	620 W 135TH ST	90248	15	078B201   103	6132005018	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	33.90897	-118.28563	T-24. Tenant improvement to an existing commercial building (wherehouse). Existing service, adding one new subpanel, connected load is less than 400 amps. Adding new lighting and receptacles. PC for energy only. Sqft = 1427	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61509	11041-10000-18529	18011 W SHERMAN WAY	91335	3	183B125    90	2121004021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			Corrections Issued	03/12/2012 12:00:00 AM	ADDRESS	34.20135	-118.5258	NEW PV SYSTEM FOR A COMMERCIAL PARKING LOT/CAR PORT AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61510	13041-20000-25406	11720 S DENVER AVE	90044	15	084B201   696	6088016023	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Expired	10/12/2015 12:00:00 AM	ADDRESS	33.9266	-118.28466	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW AC USING 18 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61511	11041-20000-15108	105 N ROBERTSON BLVD #103-105	90048	5	138B169   353	4334001012	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/19/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Closed	09/14/2011 12:00:00 AM	ADDRESS	34.07547	-118.38389	Plan check power and energy for retail TI suite #103 &105. Relocate existing panels. New ckts.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61512	15041-20000-09907	639 N FAIRFAX AVE	90048	5	141B177   747	5527017005	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			PC Info Complete	02/25/2016 12:00:00 AM	PIN	34.08277639	-118.36180845	Plan check for power and energy for new 48 units residential building 3 story and 2 parking story and 4 core and sheell commercial spaces. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61513	19041-20002-18856	112 S ROBERTSON BLVD	90048	5	138B169   408	4334005005	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM			PC Approved	10/25/2019 12:00:00 AM	ADDRESS	34.07485	-118.3836	Changes to an approved set of plans. Note changes to clouded areas.  Changes include the connection to exiting panel for temporary use. Plans to include temporary connections.   ________________________________________________________Change of use,  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61514	16041-30001-06645	2847 N SIERRA ST	90031	1	141A225   254	5208020004	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Apartment			02/25/2016 12:00:00 AM			PC Approved	04/26/2016 12:00:00 AM	ADDRESS	34.08013	-118.20181	Expedite fees only.     Installation of new roof mounted solar PV system on existing 3 unit apartment (3 meters serving two adjacent buildings).  Total system size = 3.8 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61515	13041-20000-34535	3440 S MILITARY AVE	90034	5	120B157   883	4251025024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.02178	-118.41986	New rooftop PV system using Enphase 215 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61516	12041-10000-28139	10358 W MCBROOM ST	91040	2	207B177   130	2543004004	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.26289	-118.35608	PV1 5.616KW ROOF-MOUNT ENPHASE MICROINVERTER STD PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61517	17041-10000-10104	10850 W WILSHIRE BLVD STE 110	90024	5	132B153   338	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.05923	-118.44139	PC for T24. PC includes 4 new lights, receptacles and retrofitted flourecent lighting. Total affected area is 1644 sqft. Load under 400A. Building #17016-10000-07555.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61518	18041-20000-22009	3816 N HARRIMAN AVE	90032	14	145-5A233 286	5306010038	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.09115	-118.18098	Plan check for Battery back up system 2 Tesla Power wall 2.0 connected to existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61519	19041-10001-07793	14635 W VENTURA BLVD	91403	4	166-5A151  67	2265005003	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			PC Approved	04/05/2019 12:00:00 AM	ADDRESS	34.15166	-118.45209	PER APPLICANT REQUEST ( INSPECTION CORRECTION)MINOR REVISIONS  TO T-24 FORMS.T-24 PLAN CHECK FOR A T.I. IN A RETAIL SPACE. ( NO CHANGE OF USE). SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 1505 SQ.FT SOME FEES ARE PAID UNDER THE EXPRESS PERMIT # 19041-10000-07462	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61520	13041-20001-31460	11971 N SALEM DR	91344	12	216B133   391	2606019026	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM			PC Approved	12/04/2013 12:00:00 AM	ADDRESS	34.28772	-118.50802	(((EXPEDITE FEES)))PV1 MICROINVERTER 8.1KW. 30 MODULES AND MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61521	10041-10000-12683	8500 N VAN NUYS BLVD	91402	7	192B149   148	2638001046	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.22511	-118.44865	CHANGE PORTION OF EXISTING 1-STORY TYPE V-B FULLY SPRINKLERED BUILDING FROM  BANK TO RESTAURANT (DENNY'S) CHANGE OF OCCUPANCY FROM B TO A2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61522	18041-20000-17993	333 S HOPE ST 10th Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for Title 24 energy only in existing highrise building office T.I. Total area: 4274 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61523	17041-20000-38045	1015 S ORANGE GROVE AVE	90019	10	132B177   718	5086001053	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.0575	-118.36311	Plan check for solar pv system, roof-mounted array on commercial building.Total system size: 20kW ungrounded.(2) 10kW SolarEdge inverters.(91) 300W pv modules.(91) 300W power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61524	15041-20000-10816	1100 S CORNING ST	90035	5	132B173   706	4332029001	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.05698	-118.37718	Plan check for power and energy for new 7 unit appartment 4 story with 800A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61525	19041-10000-44899	4764 N NOBLE AVE	91403	4	168B145   475	2264012011	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.15738	-118.46164	[EPLAN] PLAN CHECK FOR ESS SYSTEM(2 TESLA POWERWALLS) CONNECTED TO EXISTING PV SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61526	13041-10000-35338	710 S SANTA FE AVE	90021	14	124-5A217 282	5166002018	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			Reviewed by Supervisor	01/14/2014 12:00:00 AM	ADDRESS	34.03414	-118.22981	CHANGE OF USE FROM MIXED USE OFFICE/RESIDENTIAL TO RESTAURANT, 12,000 S.F.  (N) ELECTRICAL SERVICE AND DISTRIBUTION EQUIPMENT.  POWER AND ENERGY -	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61527	16041-10000-39739	18455 S FIGUEROA ST	90248	15	060B201    20	7339008034	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Issued	11/10/2016 12:00:00 AM	ADDRESS	33.86353	-118.28198	PC FOR INSTALLATION OF TRANSFORMER AND A COUPLE OF DISTRIBUTION EQUIPMENT FOR FUTURE INSTALLATION OF EVSE EQUIPMENT. PC FOR AIC RATING AND PROJECTED LOADS. ALL LOADS NOTED AS FUTURE AND NOT PART OF THIS PERMIT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61528	18041-10000-17837	3427 S CENTRAL AVE	90011	9	115-5A209  99	5114015044	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.01197	-118.25671	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61529	16041-10000-05141	11301 W OLYMPIC BLVD #103	90025	11	126B153  1060	4260002032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Info Complete	02/12/2016 12:00:00 AM	PIN	34.03822251	-118.44166899	PC for energy only to an ice cream shop. Adding new lighting and power. Total sqft = 320	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61530	11041-20000-23694	5900 W WILSHIRE BLVD Ste 800	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	34.06237	-118.35809	T.I  Remodel of the light fixtures in Suite 800.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61531	12041-10001-26204	5211 N BASCULE AVE	91364	3	171B109   142	2166028021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2012 12:00:00 AM			PC Approved	11/21/2012 12:00:00 AM	ADDRESS	34.16492	-118.58639	"PLAN CHECK ONLY. PERMIT IS UNDER APPLICATION NUMBER 12041-10000-26204. CHANGE OF PANEL FROM ""PANASONIC  HIT POWER 240S"" TO ""SHARP ND-2400QCJ"". CHANGE OF INVERTER FROM SUNNY BOY 7000 TO FRONIUS 7.5-1,  PV1- STANDARD PLAN PV1 7.2KW SOLAR INSTALLATION"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61532	16041-10001-31986	629 1/2 W 85TH ST	90044	8	097-5A201 156	6032018051	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	33.96122	-118.28493	09/21/16DEPARTMENT ERROR. BUILDING IS A RESIDENTIAL BUILDING NOT COMMERICAL BUILDING. CHARGING ONE PANEL FOR INSPECTION. PV1. NEW SOLAR SYSTEM FOR AN EXISTING MULTI FAMILY DWELING - ROOF-TOP (multi dwelling residential). TOTAL SYSTEM SIZE IS 3.0KWac.(8)MODULES-KYOCERA#KU2656ZPA(1)INVERTER-ABB PVI-3.0-OUTD-S-US-Z-A1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61533	14041-10000-13686	3335 S FIGUEROA ST	90007	9	120A203   503	5123009042	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.02224	-118.28008	PLAN CHECK FOR ENERGY ONLY IN COURTYARD FOR EXISTING STUDENT HOUSING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61534	16041-20000-41557	5100 N FIGUEROA ST	90042	1	150A227   160	5468005045	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	05/12/2017 12:00:00 AM	ADDRESS	34.10543	-118.20084	PLAN CHECK FOR ENERGY OUTDOORS (PARKING LOT) ONLY.  TOTAL QUARE FOOTAGE 77966.REPLACEMENT WITH NEW LED LIGHT FIXTURES WIRING TO REMAIN.  NO NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61535	14041-20001-18314	21308 W NASHVILLE ST	91311	12	210B105   187	2706032024	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.26892	-118.5959	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 10kW.(1) IG Plus Advanced 10.0-1 UNI transformered inverter(30) SunPower SPR-327NE-WHT-D pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61536	09041-20002-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			Corrections Issued	04/07/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 16	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61537	18041-10000-27446	10161 N HILLHAVEN AVE	91042	7	204B197   964	2565013037	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1012.10	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM			Reviewed by Supervisor	07/31/2018 12:00:00 AM	ADDRESS	34.25403	-118.28995	NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL SENIOR LIVING FACILITY. SYSTEM CONSIST OF 130 MODULES (NEO SOLAR 355W) AND 4 INVERTERS  (GINLONG SOLIS 3*10KW, 6KW) .  SYSTEM SIZE IS 46.15KWdc and 36KWac. SCOPE INCLUDES NEW 400 AMPS PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61538	18041-20000-27413	1800 N DOHENY DR	90069	4	150B169  1279	5561008014	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2018 12:00:00 AM			Reviewed by Supervisor	10/17/2018 12:00:00 AM	ADDRESS	34.10458	-118.38813	Plan check for power only. Project site is a new 2-story single-family dwelling with a basement. Work includes a 600-amp service.this is plan check only.Note: Building applications for the SFD, the pool room, and the pool cabana can be found under 17010-30000-04488, 17010-30000-04491, 17010-30000-04492, respectively. Electrical permit fees have been paid under the building permits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61539	12041-10000-05634	110 E 22ND ST bldg 9	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM	05/10/2012 12:00:00 AM		Permit Closed	03/10/2016 12:00:00 AM	ADDRESS	33.72668	-118.27682	PLAN CHECK POWER.  NEW 600A SERVICE FOR BUILDING 9. FUTURE RETAIL SPACE.ALL LOADS ARE FUTURE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61540	17041-10000-18828	267 N BELMONT AVE	90026	13	136-5A207 327	5159010022	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2083.02	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.06668	-118.2634	PC for energy only, Outdoor title 24. Removing existing fixtures and replacing them with LED lights. Area: 15,750sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61541	16041-10001-25611	4551 S GLENCOE AVE	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	33.9844	-118.43407	pc for FA system.This is a supplemental permit for 3 panels that are not accounted under the master permit. NEW DESIGN BUILD F/A SYSTEM T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61542	13041-10000-20115	1135 N RIVAS CANYON ROAD	90272	11	129B129   182	4409005027	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2013 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.05074	-118.51584	changes on plan: receptacles for outdoors and lights for illumination of egress and future EV service load calcs. Assumed fault current is 100k per applicant.Most permit fees pulled under combined permit 09010-20000-00871.Inspector requested permit fees for 600A panel and service.pc for power and energy. new (N) SINGLE FAMILY-DWELLING , 2 STORY-HOUSE , SERVICE SIZED AT 600A. ELECTRICAL SERVICE FOR MAIN DWELLING, GUEST HOUSE & POOL HOUSE. not a methane zone.bldg description for 09010 - 20000 - 00871:(P) R3 Occ. Group: +9510 Sqft / 9510 Sqftany subsequent changes require additional fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61543	10041-20002-04897	2530 E CINCINNATI ST	90033	14	129A225   348	5177033028	R3-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2037.20	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM			PC Info Complete	07/25/2011 12:00:00 AM	ADDRESS	34.04626	-118.20433	REVISION TO APPROVED PLANS DELTA 8	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61544	14041-10000-19105	12013 W WILSHIRE BLVD 1st FL	90049	11	129B145  1047	4265014105	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	PIN	34.04576502	-118.46601032	TENANT IMPROVEMENT. ADD NEW PARTITION WALLS. CHANGE OF USE OF THE BUILDING FROM RETAIL TO MASSAGE. T.I. ON THE FIRST FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61545	16041-30001-10007	13430 W CHALON ROAD	90049	11	138B133   369	4492003001	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.07323	-118.50032	Expedite fees only.      Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 13.750 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61546	15041-10000-12117	12775 W MILLENNIUM SUITE 4110	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Issued	09/30/2015 12:00:00 AM	ADDRESS	33.97584	-118.4171	TI, FIRST TIME TENANT. PC FOR POWER AND ENERGY. CORE & SHELL APPROVED UNDER SEPARATE APPLICATION 12041-10k-30783.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61547	16041-20000-45439	1525 N CAHUENGA BLVD	90028	13	147A187    45	5546013020	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	07/10/2019 12:00:00 AM		Issued	07/10/2019 12:00:00 AM	ADDRESS	34.09886	-118.32967	Plan check for power and energy. Project site is a new 7-story, 64-guestroom hotel with 2 restaurants over 1 level of basement parking garage. Total lighting area = 39,008 sq. ft.Note: Building application has been generated under 16010-20000-03177	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61548	16041-10000-45141	900 W WILSHIRE BLVD	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT PLUS STORAGE SPACE IN  LOWER LEVEL.TOTAL AREA 15238 SQ FT.Bldg #16016-10000-30546	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61549	17041-20000-17705	13703 W VICTORY BLVD	91401	2	180B157   930	2238013053	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.18683	-118.43167	New panel feeding gas pumps/dispensers for service station.  Hazardous classification.Service station permit with new 600A service issued under 16041-20000-40798	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61550	16041-30003-08448	13630 W SATICOY ST	91402	6	186B157   140	2214025004	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM			PC Approved	02/02/2017 12:00:00 AM	ADDRESS	34.20928	-118.42941	02/02/2017 Changes to an approved set of plans. Changes have been clouded and marked as Delta 2. Changes have been made to include AC fused disconnects and a subpanel.[[2/1/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. CHANGES ARE CLOUDED. REMOVING A DISCONNET, INSTALLATION OF A 400AMP PANEL, ADJUSTING FEEDER SIZES AND DERATE CALCULATIONS]]]]Plan check for PV system on conbination of roof mount and new carport in existing roof. Total system size: 302.2kW with 828 modules and 6 inverters(STP24000TL-US) and 2 inverters(STP2000TL-US) connect to supply side tap.     low fees due to senate bill1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61551	18041-20000-01655	10140 N MCVINE AVE	91040	7	204B193  1541	2559021082	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Issued	01/16/2018 12:00:00 AM	ADDRESS	34.25371	-118.31127	pv1install roof mounted pv system sized 6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61552	16041-10000-14046	401 S WESTERN AVE	90020	10	135B193   483	5503015024	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2117.03	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM			Corrections Issued	05/23/2016 12:00:00 AM	ADDRESS	34.06702	-118.30939	PC FOR POWER AND ENERGY.  5-STROY MIXED USE RETAIL  & 57 UNIT APARTMENT BUILDING  OVER 2 LEVEL  SUBTERANEAN PARKING GARGE. 3000A SERVICE. 4 types panels. TOTAL AREA 74090 SQ FT.B# 15010-10000&1-00659	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61553	19041-20000-50766	13921 W VANOWEN ST 1-15	91405	2	183B153  1023	2216017011	R1-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Apartment			12/10/2019 12:00:00 AM			PC Info Complete	09/18/2020 12:00:00 AM	ADDRESS	34.1941	-118.43637	FULL PLAN CHECK FOR A NEW 800A, 120/240V SERVICE. SCOPE OF WORK INCLUDES HOUSE PANEL, DWELLING UNITS PANELS AND ASSOCIATED LOADS. NEW LIGHTING, CIRCUITS AND CONTROLS. TOTAL AFFECTED AREA IS 14,122 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61554	17041-10000-11695	1028 E VERNON AVE	90011	9	112-5A209  63	5108028007	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.00368	-118.25756	Installation of  a new fire alarm system for a commercial site. (1) New Fire alarm with (35) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61555	18041-10001-34393	935 E 59TH ST	90001	9	105B209     4	6007003011	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Closed	01/26/2024 12:00:00 AM	ADDRESS	33.98736	-118.25812	Change to approved set by modifying the floor plan and load calculation. New ckts also added, all changes under delta-2 through 5 only.(((Plan check for power and energy. Project scope is a change of use from warehouse to indoor nursery. Work includes a complete tenant improvement and a total lighting area of 37,495 sq. ft.Note: Building application has been generated under 18016-20000-29130 )))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61556	14041-10000-24352	4605 N LANKERSHIM BLVD #400/421	91602	2	168B173   921	2421028013	C2-2	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	34.15405	-118.36832	Plan check for energy only. T24 on the 4th floor. No change in occupancy. Tenant improvement of offices. high rise. 11490 sq. ft. Emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61557	15041-10000-22477	11445 N PETIT AVE	91344	12	213B133   760	2682005011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	PIN	34.27863511	-118.49898739	PV1.  Install 7.5 kW DC roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61558	19041-10000-22509	550 S HOPE ST # 460	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
61559	18041-10000-32675	9725 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM			PC Info Complete	12/04/2018 12:00:00 AM	ADDRESS	34.24604	-118.41908	FULL PC FOR POWER AND ENERGY. TI TO (E) RETAIL BUILDING. SCOPE INCLUDE NEW LIGHTS, CIRCUITS, AND ONE 225A PANELBOARD. NEW CONNECTED LOAD > 400A. TOTAL AFFECTED AREA IS 100,462 SQ. FT.   B#18016-10000-16455	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61560	13041-10000-31951	7133 N OWENSMOUTH AVE	91303	3	183B105   268	2111025010	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.20012	-118.60173	NEW FIREALARM SYSTEM FOR SPRINKLER MONITORED  BUILDING. 1 STORY. 2 PANELS AND 47 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61561	18041-20000-41275	14006 W RIVERSIDE DR fc4	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61562	12041-20000-10212	4222 W PICO BLVD	90019	10	129B185  1095	5082023024	C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM			PC Approved	05/04/2012 12:00:00 AM	ADDRESS	34.0477	-118.32765	Plan check for energy and emergency lighting. 1349 conditioned sqft. Single story commercial. Mateo's Ice Cream and Fruit Bars.  Modification to original approved lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61563	13041-20000-35726	12001 N SALEM DR	91344	12	216B133   288	2606010031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	34.28893	-118.50854	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 5.8KWAC. 27 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61564	13041-20000-33127	7325 N MEDICAL CENTER DR	91307	12	186B097   830	2021014040	(Q)CR-1VL, CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/27/2013 12:00:00 AM	ADDRESS	34.20328	-118.62963	T24 FOR EXISTING WOMENS DIAGNOSTIC CENTER. SCOPE OF WORK NOT IN ANY MEDICAL AREAS. NO WORK BEING DONE IN MAMMOGRAM ROOM ONLY IN DRESSING AND READING ROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61565	14041-20001-35052	16237 W NORDHOFF ST	91343	12	198B137  1007	2676015013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.23582	-118.48645	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(18) SUNPOWER SPR-327 MODULES(1) AURORA PVI-6000 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61566	14041-10000-09980	11829 W CULVER BLVD	90066	11	111B161  1042	4233022015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	33.99679	-118.41674	Intall roof-mounted solar array, interconnect with main panel.  System size 3 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61567	13041-10001-32390	10431 N GENESTA AVE	91344	12	207B133   968	2695019041	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	02/04/2014 12:00:00 AM	ADDRESS	34.26047	-118.50468	Expedited RSES plan  check per applicant request.(((PV1, Install 6 kW DC roof-mounted solar array for a one story house, interconnect with service panel. Transformered inverter. Fronius IG 5100 NEG. 24 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61568	19041-10000-47302	10320 N KEY WEST AVE	91326	12	204B117   128	2728009030	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.25804	-118.55343	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 13.2KWdc (11.52KWac) USING 33 SP A400 AC MODULES.CONNECTED TO A 225 AMP NEW SERVICE.Fess $69.37 due to California Senate Bill 1222 and AB 1414NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61569	19041-20000-05855	17162 W PARTHENIA ST pv1	91325	12	195B133   457	2690015047	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.22839	-118.50804	pv1install roof mounted pv system sized 11.5KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61570	14041-10000-25405	11050 W MAGNOLIA BLVD	91601	2	171B173   611	2353005001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			PC Approved	09/16/2014 12:00:00 AM	ADDRESS	34.16478	-118.3723	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. Change  of  use  from  theater  to a restarant . NEWLY CONNECTED LOAD  <400 AMPS. 4970 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61571	17041-20001-00448	9255 N CORBIN AVE	91324	12	198B117   150	2761001075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.23837	-118.56248	01/18/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,042 sq. ft. *****Previous Work Description*****NEW OUTLETS WITH BRANCH CIRCUITS TO PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61572	19041-20000-05887	18080 W CHATSWORTH ST 2B	91344	12	207B125   637	2731008023	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.26439	-118.52639	TI to (E) commercial restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61573	15041-10001-23907	2651 S HOBART BLVD	90018	8	123B193   848	5053011024	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Apartment			07/25/2016 12:00:00 AM			PC Approved	07/25/2016 12:00:00 AM	ADDRESS	34.0311	-118.30806	7/25/16: Revision to approved plan noted as Delta-3. Revise light fixtures being used. Changes only affect T-24. This is Plan check only. Permit shall be issued under master. <<NEW 2 STORY APARTMENT BUILDING 800 AMPS SERVICE.  PLAN CHECK FOR POWER AND ENERGY. FIRE VARIANCE NOT RQUIRED.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61574	15041-10000-05452	3274 W 6TH ST	90005	10	135B197  1010	5502026016	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.06347	-118.29383	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 555.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61575	15041-10000-33115	1105 N RIVAS CANYON ROAD	90272	11	129B129  1031	4409005026	RE40-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2015 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	34.05007	-118.51597	PC FOR POWER ONLY, NEW 2 STORY RESIDENTIAL BUILDING WITH A GUESTHOUSE AND 3 CAR GARAGE. NEW 600 AMP SERVICE, SCOPE INCLUDES NEW LIGHITNG AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61576	19041-10000-40808	2212 W VERNON AVE	90008	8	111B189   283	5015026026	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress Central Area		2345.02	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	12/22/2020 12:00:00 AM	ADDRESS	34.00351	-118.31793	Full plan check for power and energy. Scope includes new 800A 120/240 3ph 4w service, new panels, new circuits, new lights.  Total affected area is 12985 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61577	11041-10002-02008	20801 W RINALDI ST	91311	12	210B109   548	2706007024	(T)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.00	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.27025	-118.58647	REVISED  PLANS- ADDING/RELOCATING  12 FA DEVICES((((((((New fire alarm system for the athletics building.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61578	15041-20000-42674	7733 N LEMONA AVE	91405	6	189B145   724	2209037049	MR2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.21132	-118.45954	Plan check for Title 24 only in existing wearhouse T.I.  Total area: 19,600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61579	19041-10000-24392	5815 W 96TH ST APM-TPSS	90045	11	093B169   162	4125023931	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Issued	12/20/2019 12:00:00 AM	ADDRESS	33.94956	-118.38359	Distribution to Automated People Mover (APM) Train System, scope inlcudes 750-volt DC power to feed APM guideway rail and 480-volt auxilary power	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61580	15041-20000-43807	22534 W LASSEN ST	91311	12	201B097    18	2727003004	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.24973	-118.61814	PV1, rooftop solar installation 6kW AC system(23) SE-F270(1) SE6000A-USSE P300 is used.Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61581	16041-20000-22709	4121 N EAGLE ROCK BLVD	90065	14	156A219   137	5473006006	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Apartment			06/28/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.12142	-118.22666	Fire alarm system for (N) 46 unit 4-story over basement apartment building.  (1) FACP with (103) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61582	10041-10000-17429	2242 S PURDUE AVE	90064	11	123B153   171	4260018012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	01/06/2011 12:00:00 AM	ADDRESS	34.03585	-118.44197	INSTALLATION OF ROOF-MOUNTED 45KW SOLAR VOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61583	13041-10000-18306	14301 W COHASSET ST	91405	6	186B153    76	2215022004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.20676	-118.44463	ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING TO EXISTING MAIN PANEL. SYSTEM SIZED AT 6.37 KW IN A 2-STORY HOUSE.  PV1 6.37KW XFRMless. 2 STORY. nonSTD. ROOFMOUNT.  [1 INV: SE6000A ] [ 26MOD:  TRINA TSM-245PC05} with optimizers, OP250-LV-MC4SM-2NA ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61584	19041-10000-38733	780 E 12TH ST	90021	14	123A211    88	5132012061	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.03235	-118.25098	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61585	16041-10001-01522	15797 W COBALT ST	91342	7	222B141   244	2604009031	RA-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.30244	-118.47508	EXPEDITED FEES PER APPLICANTS REQUEST. (((PV1, ROOF MOUNTED SOLAR SYSTEM, (38) MODLUES WITH (2) 6KW INVERTERS. TOTAL SIZE: 12KW)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61586	19041-20001-07931	639 N NORTH BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Apartment			03/05/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	34.05972	-118.2398	PLAN CHECK FOR NEW 336.24 KW DC/301.94KW AC ROOF MOUNTED PV SYSTEM FOR EXISTING APARTMENT BUILDING. SCOPE OF WORK INCLUDES (934) ASTROHALO 360W PV MODULES, (9) SE33.3KUS INVERTERS, AND (467) P730 SOLAR EDGE POWER OPTIMIZERS, (1) 250A LOAD CNETERN AND (1) 600A LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61587	16041-10000-05918	3785 W WILSHIRE BLVD #217	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Info Complete	03/29/2016 12:00:00 AM	ADDRESS	34.06187	-118.30858	PC FOR POWER ONLY. CORE AND SHELL FOR A NEW TENANT (UNIT #217) IN A MULTI UNIT HIGH RISE BUILDING. SCOPE OF WORK  INCLUDES UPGRADING POWER TO AN EXISTING EMPTY TENANT SPACE, NEW 200A PANEL, NEW 45KVA TRANFORMER, NEW 125A PANEL, AND FOUR NEW AIR CONDITIONING/FAN COIL UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61588	16041-20000-10416	8231 W 3RD ST	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM			PC Info Complete	04/19/2016 12:00:00 AM	ADDRESS	34.07272	-118.36914	CHANGE OF USE FROM (E) MERCHANTILE TO (N) GYMNASIUM(3606 s.f) in (E) single-story commercial building.  Plan check for power and energy per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61589	17041-20000-30964	5821 N COLUMBUS AVE	91411	4	174B145   104	2243018010	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.17646	-118.4641	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61590	18041-20000-16479	14856 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.2943	-118.45493	PV1.  Install 3 kW roof mounted PV system.  (11) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61591	19041-10000-43395	8100 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	33.95164	-118.43579	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61592	18041-10001-26784	16824 W CALLE MONTECITO	90272	11	138B121     9	4431038050	(Q)RD3-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	ADDRESS	34.07826	-118.54925	CHANGES TO APPROVED SET SCOPE INCLUDES CHANGING OF MODULE TPE  SOLARCITY STANDARD SC320 TOTAL NEW SYSTEM SIZE 8.64KW DCTHIS IS PLAN CHECK ONLY! PERMIT PAID UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61593	11041-10000-24798	4666 N FARMDALE AVE	91602	2	168B169   704	2354013038	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM			Corrections Issued	02/27/2012 12:00:00 AM	ADDRESS	34.1558	-118.38114	INSTALLATION OF A 10KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61594	14041-10000-27574	7419 N BELLAIRE AVE	91605	2	186B161   476	2305026036	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM			PC Info Complete	10/08/2014 12:00:00 AM	ADDRESS	34.20638	-118.40974	Power plan check for new service upgrade from 200 Amp to 600 Amp. main equipment including (2) 200 Amp panels, and an 80 Amp oven.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61595	17041-10000-38915	10347 N AMESTOY AVE	91344	12	204B133    87	2695018013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.25907	-118.50682	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.45KWdc / 3.20KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61596	16041-20000-37704	14800 W SHERMAN WAY	91405	6	183B149    89	2219001015	R1-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.20097	-118.45535	remove existing hid fixtures and replace with new led fixtures outdoors.  plan check for energy 128362 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61597	14041-10000-23105	798 E 12TH ST	90021	14	123A211    98	5132012061	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.0321	-118.25075	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 845 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61598	10041-10002-03056	6750 W SUNSET BLVD	90028	13	147A185    92	5547021001	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.09769	-118.33815	NEW RESTAURANT- CHICKEN FILLET, Changes to the BRKR fully and series rating.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61599	19041-20000-25347	350 S GRAND AVE STE 1630 &-1650	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	08/07/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.05173	-118.2522	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61600	18041-20000-30748	1411 N HIGHLAND AVE #B & C	90028	4	147A185   220	5548015037	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	11/21/2018 12:00:00 AM	ADDRESS	34.09649	-118.33888	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61601	15041-20000-02752	10924 N KEY WEST AVE	91326	12	210B117   312	2718021005	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.26878	-118.55357	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(23) CANADIAN SOLAR CS6P-250P and CS6P-235PX MODULES(23) SOLAR EDGE P300 POWER OPTIMIZERS(1) SOLAR EDGE SE5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61602	16041-10000-19204	427 W 5TH ST	90013	14	129A211    12	5149028012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM			PC Info Complete	09/27/2016 12:00:00 AM	ADDRESS	34.04937	-118.25245	MEHTHANE GAS DETECTION SYSTEM FOR NEW BUILDING. 30 EVICES AND CONTROL PANEL. PC IN ACCORDANCE TO METHANE MITIGATION STANDARDS. NOTE: PERMIT IS PULL UNDER SUPPLEMENTAL: 16041-100000-19204	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61603	19041-20000-50994	3644 S BARRINGTON AVE	90066	11	114B157   466	4234017009	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	07/07/2020 12:00:00 AM	ADDRESS	34.01031	-118.42891	Plan check for PV roof mounted system, PV system size: 6.0KW with 15 AC Modules, 1 sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61604	15041-10000-34610	1205 E 6TH ST	90013	14	126A215   332	5164009012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			10/16/2015 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	PIN	34.03841309	-118.23802517	PLAN CHECK FOR RENOVATION OF AFFORDABLE HOUSING BUILDING. UPGRADING SERVICE AND DISTRIBUTION AND COMMON AREA CIRCUITING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61605	13041-10000-08914	3515 S MOUNTAIN VIEW AVE	90066	11	114B153   135	4248023033	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Expired	05/01/2015 12:00:00 AM	ADDRESS	34.01204	-118.43515	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE STORY HOUSE. SYSTEM SIZE IS 6.125KW USING 25 MODULES  2 STRINGS AND 1 TRANSFORMERLESS INVERTER AND POWER OPTIMIZERS. [MODULES: TRINA SOLAR # TSM-245PC/PA05 |||| INVERTER: SOLAREDGE # SE6000A-US |||| OPTIMIZER: SOLAREDGE # OP250-LV]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61606	11041-10000-18020	132 S ROBERTSON BLVD	90048	5	138B169   438	4334005006	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	11/07/2011 12:00:00 AM	ADDRESS	34.07447	-118.3836	T.I.  One story retail place.  Retail used to be a makeup retail and a new make up retailer (Make up For Ever) is to occupy the space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61607	12041-10000-28806	12722 W ALBERS ST	91607	5	174B161   669	2346005019	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.17021	-118.41016	7.92 kw Roof mounted PV for a single family. (PV1)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61608	15041-20000-03245	5143 N HERMOSA AVE	90041	14	163-5A223 275	5669025008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.14056	-118.2077	PV1MICROINVERTER STANDARD PLAN SYSTEM SIZE 6.4KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61609	11041-20001-05520	780 N SWARTHMORE AVE	90272	11	126B125   117	4412009031	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	07/12/2014 12:00:00 AM	ADDRESS	34.04464	-118.52629	Supplemental application to include T24 outdoor lighting to approved plans and 2 branch ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61610	12041-10000-10298	4130 S DEL REY AVE	90292	11	108B153  1251	4230005047	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	33.98812	-118.44458	"New office addition within existing building envelope.   Occupancy load is less than 99 and electrical load is 100 amps, per applicant.  Permit fees are under ""Inspection"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61611	16041-20000-40798	13703 W VICTORY BLVD	91401	2	180B157   930	2238013053	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.18683	-118.43167	Plan check for Title 24 only. Project site is a new foodmart. Total lighting area = 13,054 sq. ft.Note: Building permit has been pulled under 14010-20000-01710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61612	17041-20000-26277	9239 N LAMIA CT	91343	7	198B145   477	2651023***	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.23865	-118.4598	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61613	15041-10000-28262	633 W 5TH ST # 1000	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR ENERGY. T.I FOR COLDWELL BANKER OFFICE. HIGH RISE. NO CHANGE OF USE  # 1000, TOTAL AREA 4224 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61614	19041-20000-39438	5443 N SADRING AVE	91367	3	174B093   518	2044007008	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.16961	-118.6366	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 12.87 KW DC/ 11.4 KW AC. SCOPE OF WORK CONSISTS OF (39) PV MODULES WITH OPTIMIZERS AND A 11.4 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61615	13041-10000-10585	25965 S NORMANDIE AVE 2nd-3rd	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	T24 FOR MEDICAL OFFICE. RECEPTION AND WAITING AREA ONLY. NO PATIENT CARE AREAS IN THE SCOPE OF WORK. WORK BEING DONE ON 2ND AND 3RD FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61616	10041-10000-03844	11760 W TRUESDALE ST	91352	6	201B169   102	2537021903	[Q]PF-1XL, [Q]PF-1XL-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM	04/26/2010 12:00:00 AM		Permit Expired	09/14/2012 12:00:00 AM	ADDRESS	34.24861	-118.38792	Install general outdoor lighting at truckwash canopy.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61617	12041-10000-12446	1200 S CLUB VIEW DR 11 SOUTH	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00, 2657.00	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.06748	-118.42481	Plan check T24 Energy/Emergency lighting for new corridor expansion on the 11th floor (south). Permit for new lighting and exit signs on existing branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61618	10041-20000-02594	1990 S BUNDY DR #520	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	02/16/2010 12:00:00 AM		Permit Finaled	04/19/2010 12:00:00 AM	ADDRESS	34.03419	-118.45559	s.520 office t,i,Energy, emergencyFire Alarm system is by others 01041-10000-25799	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61619	15041-20000-22837	325 W ADAMS BLVD	90007	9	121-5A205 132	5126018032	(T)(Q)C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Issued	08/10/2015 12:00:00 AM	ADDRESS	34.02712	-118.27319	Plan check for 1st time tenant in mixed used building. Total indoor area: 4470sqft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61620	14041-20000-15639	1238 W 30TH ST	90007	9	120B197   348	5039001050	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.02732	-118.29004	New 3-story duplex with grade-level parking.  New 600A service to supply new duplex as well as existing 2-story triplex.  Plan check for power	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61621	17041-10000-39562	9223 N OWENSMOUTH AVE	91311	12	198B105   134	2746012039	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.238	-118.60204	CHANGE OF USE : PORTION OF EXISTING WAREHOUSE ( 34' X 25' ) TO FOOD PROCESSING ROOM TO INCLUDE NEW IMP WALLS AND CEILINGS, FLOOR DRAINS, LIGHTS .PLAN CHECK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61622	19041-20000-32581	20971 W BURBANK BLVD	91367	3	174B109   299	2149017015	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.17347	-118.59094	Additional emergency egress lighting in (E) commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61623	09041-10003-24028	8640 W 3RD ST	90048	5	138B169   564	4334011021	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			PC Approved	06/26/2012 12:00:00 AM	ADDRESS	34.07338	-118.38114	PLAN CHECK FOR FIELD REVISIONS TO APPROVED SET OF PLANS: LIGHTING FOR STAIRWAYS BETWEEN 2ND AND 3RD FLOORSWERE CHANGED;TITLE 24  FORMS WERE UPDATED TO SHOW THAT RETAIL AREA WAS REMOVED AND EXTERIOR LIGHTING ADDED AND OCCUPANCY SENSORS ADDED TO 2ND & 3RD FLOORS AND CHANGES TO LUMINAIRES ON THOSE FLOORS. ALL CHANGES ON THE PLANS ARE CLOUDED(((((((((New 3-story Medical building.  Permit is for new service, new switchboard, new panels, new ckts, new equipment.  T-24 was not included in original submittal.  P/C is for Power and Energy.  A control panel shall be provided to allow no more than 2 car jacks on panel HJ to operate at the same time.  This is called out in Specific note 8 on sheet E-3.  Any changes on the system will require replan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61624	15041-20001-28529	14015 W VENTURA BLVD	91423	4	165B153   422	2271014013	C2-1VL, R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.14929	-118.43784	"11/15/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Change have been made to the lighting system and have been reflected onto the Title 24 Compliance forms.*****Previous Work Description*****Title 24 plan check only.  Total area = 4,018 sq. ft.  T.I. to existing restaraunt space.  369 A load.  New lighting, recepticles, and equipment.""COMPLY WITH DEPARTMENT ORDER effective date 02/10/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61625	19041-20001-42595	11237 N NORRIS AVE	91331	7	210B157   154	2534003012	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM			PC Approved	12/10/2019 12:00:00 AM	ADDRESS	34.27428	-118.42063	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO COVER PAGE AND ROOF PLAN, RELOCATION OF PV MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61626	14041-20000-09897	10439 N BAIRD AVE	91326	12	207B125   608	2728026004	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.26029	-118.53743	PV1. ROOFMOUNTED SYSTEM. TRANSFROMERLESS INVERTER WITH POWER OPTOMIZERS. SYSTEM SIZE: 2.75 KW.(11) CANADIAN SOLAR CS6P 250(1) SOLAREDGE # SE3000A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61627	11041-10000-16041	3584 S FIGUEROA ST 1-56	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Closed	12/07/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	600A Temporary Service, overhead drop and main swbd. only, for construction of:(MIXED-USE BLDG WITH FIVE STORY APARTMENT, 56 UNITS (TYPE III A) OVER ONE STORY OF RETAIL (TYPE I A) OVER THREE LEVELS OF SUBTERRANEAN GARAGE (TYPE I A). NFPA-13 automatic fire sprinkler system throughout for story increase per Sec. 504.2.)NOTE: Distribution equipment and wiring for this temporary service are submitted under a separate application due to separate contractors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61628	16041-10000-44298	4000 S LA BREA AVE	90008	10	117B177   657	5028004902	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.01465	-118.35525	Intallation of a fire alarm system to an existing commercial building. (3) Fire Alarm Panel, (26) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61629	13041-20000-03616	3507 S TROUSDALE PKWY NCT	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM			PC Approved	02/12/2013 12:00:00 AM	ADDRESS	34.02187	-118.2846	Plan check for energy only. Installation of fan-coil units on rooftop. Eileen L. Norris Cinema Theater. NCT building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61630	14041-10000-00041	701 E NEW DOCK ST CRANE SHOP	90731	15	024B209   298	7440021914	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.75567	-118.25325	NEW FIRE ALARM SYSTEM FOR CRANESHOP OF 38 DEVICES, 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61631	14041-10000-06997	12057 W WILSHIRE BLVD	90049	11	126B145    66	4265016027	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM			PC Approved	03/17/2014 12:00:00 AM	PIN	34.04495689	-118.46700701	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR A STARBUCKS KIOSK INSIDE RALPHS. 560 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61632	17041-10000-43136	2015 W 42ND ST	90062	8	114B189  1089	5022013015	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.00735	-118.31599	PV1 5KW roofmounted system with (21) Enphase Microinverter and modules interconnecting through the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61633	16041-20000-32644	3461 S GRAND VIEW BLVD	90066	11	114B153    96	4248017021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Issued	11/18/2016 12:00:00 AM	ADDRESS	34.01227	-118.43713	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222Plan check for installation of roof-mounted solar array on SFD. Interconnect with 400A split bus panel.15.2kW ungrounded system (7.6+7.6). (64) 320W pv modules. Each module has a 320W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61634	17041-10001-44080	4371 N EAGLE ROCK BLVD	90041	14	157-5A219 375	5473026013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.01	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.12399	-118.22146	[[[7/20/18 changes to approved set. Reducing (3) modules and microinverters.  new system size : 11.3kw DC , 9.859 CECAC]]PC for 14.4kW(AC) PV Enphase Microinverter system mounted on roof of a church. Scope includes 36 modules, (36) IQ6plus microinverters, and a 60A load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61635	12041-10000-09808	788 S ALAMEDA ST #1-#32	90021	14	123A215    48	5166031014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM			PC Approved	05/16/2012 12:00:00 AM	ADDRESS	34.03054	-118.23869	Existing warehouse, electrical work to repair a leaking roof.  Entire warehouse is for commercial refrigeration storage.  Permits are existing.  Plan check only for Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61636	17041-10001-16175	1050 S GRAND AVE Suite 200	90015	14	127-5A207 345	5139010***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM			PC Approved	04/03/2018 12:00:00 AM	ADDRESS	34.04171	-118.26155	"[[ 4/3/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA  "" A"" CHEANGS ONLY. CHANGES TO FLOOR LAYOUT AND TITLE 24]]Plan check for power and Title 24.  Change of use from retail to dental office in mixed use highrise building.  New 75 kVA transformer and new 225 amp subpanel feeding new lighting and receptacles.  Total area = 1,246 sq. ft.       Building permit #17016-10000-11257"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61637	13041-10000-35742	5840 W CENTINELA AVE	90045	11	102B169    68	4103005033	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Info Complete	03/11/2014 12:00:00 AM	ADDRESS	33.97633	-118.38267	Plan check for power and energy. Installation for new electrical vehicle charging. No new panel. Total area is 24294 sq ft [indoor]. Tesla service station (auto repair) . Not methane. not hazardous location (lithium batteries)	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
61638	18041-20000-15585	117-119 3/4 N MANHATTAN PL	90004	4	138B193   939	5516026007	R3-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.07362	-118.31078	Plan check for new Fire alarm system for samll lot subdivision for 8 houses. Total alarm devices: 4 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61639	10041-10000-22239	6240 N LANKERSHIM BLVD	91606	2	177B169   177	2335029901	R3-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.01	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	01/28/2011 12:00:00 AM	ADDRESS	34.18433	-118.38614	Outdoor lighting for a parking. Plan check for T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61640	18041-10001-42452	8235 W LINCOLN TER	90069	4	147B173   294	5555024017	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM			Reviewed by Supervisor	11/13/2018 12:00:00 AM	ADDRESS	34.09777	-118.37009	Void application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61641	18041-20001-40036	14631 W DICKENS ST	91403	4	166-5A149  93	2276002***	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Apartment			02/15/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.15059	-118.45307	Revision to approved set of plans.  Clarified note to indicate connection to dedicated Class C disconnect switch.(((Plan check for replace new fire alarm panel  and add 1 new smoke detector above fire alarm, 1 new pull station and tie existing fire alarm devices to the new Fire alarm panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61642	18041-20001-25013	11650 W PICO BLVD	90064	11	123B153   717	4260033033	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.03185	-118.4448	8/27/2018changes to an approved set of plans. changes to add oven cook top and laundry loads to exisitng tenant panels R1A-R5A only.  ((((Initial TI and change of use from retail to office for mixed-use building tenant spaces.  Plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61643	18041-10001-12339	2112 W SUNSET BLVD STE I	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM			PC Approved	09/26/2018 12:00:00 AM	ADDRESS	34.07733	-118.26419	PC PER APPLICANT REQUEST TO REFLECT FIELD CONDITIONS. SCOPE INCLUDES SOME REVISIONS TO FLOOR PLAN (NO NEW LIGHTS) .THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61644	11041-10000-15365	1614 W WILSHIRE BLVD STORE #2	90017	1	132A205   217	5142012005	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.05542	-118.27078	TI TO AN EXISTING RETAIL SPACE.  SPACE WILL BE FOR FURNITURE/LAMP RETAIL.  PLAN CHECK IS FOR ENERGY ONLY.  ((((((((TWO SEPERATE APPLICATIONS WILL BE ASSIGNED TO THIS SINGLE PLAN FOR TWO SEPERATE STORES.  THIS PLAN CHECK IS FOR STORE #2))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61645	13041-20002-31214	12727 W SHERMAN WAY	91605	2	183B161    11	2324004004	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	11/15/2014 12:00:00 AM	ADDRESS	34.20137	-118.41091	[[[[11/13/14 changes to approved set of plans. plancheck only. changes to all the laundry ckts and loads]]]]]]Changes from previously approved plans.  Change in feeder interconnection with the service panel and lighting.  Plan check for power and energy.Note: Permit is under the original application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61646	15041-10000-29482	3130 S SEPULVEDA BLVD Ste 3002-1/2	90034	5	120B157   404	4251011036	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM			PC Approved	09/08/2015 12:00:00 AM	ADDRESS	34.02599	-118.42733	PC for energy only, t-24 to an existing commercial bldg (AT&T). Scope of work: installing new lighting fixtures. SqFt = 1902	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61647	12041-20000-10018	2922 N BEVERLY GLEN CIR	90077	5	156B153    17	4382030065	RE15-1VLD-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM			PC Approved	05/02/2012 12:00:00 AM	ADDRESS	34.12759	-118.44343	TI  NEW KITCHEN  WI COOLER, ADA RESTROOMS FOR AN EXISTING RESTAURANT SPACE. Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61648	17041-20000-11219	5757 W WILSHIRE BLVD SUITE 670	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE SPACE "" SIAMAK VAZIRI"" . 6743 SQFT.  SUITE 670building permit # 17016-10000-05260"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61649	14041-10000-30303	21800 W VICTORY BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.18712	-118.60325	New fire alarm system for a commerical building (Costco wholesale). total (1) control panel, (1) fire alarm panel and (166) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61650	18041-10000-07384	939 S BROADWAY 1ST FLR.	90015	14	127-5A209 278	5139003006	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.04157	-118.25708	PC FOR FIRST TIME TENANT NEW RESTAURANT IN HISTORIC BUILDING (HI RESTAURNT).SCOPE INCLUDES PANELS EQUIPMENT AND CIRCUITS.TOTAL AFFECTED 3177 SQ. FT. ( NO OUTDOORS LIGHTING)B#18016-10000-03224	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61651	17041-20001-12515	8850 N CORBIN AVE	91324	12	195B117    62	2783025091	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Issued	01/04/2018 12:00:00 AM	ADDRESS	34.23146	-118.56211	Revisions to approved set of plans.  Update of plans to reflect (E) site conditions - (3) additional circuits relative to original permit scope.  (((ti to an existing commercial building single story.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 2349.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61652	18041-10000-21956	2049 S CENTURY PARK EAST Suite#1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN AN EXISTING OFFICE AREA IN SUITE #1940 ON THE 19TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61653	16041-20000-22444	232 S CATALINA ST	90004	13	135B197    86	5518022007	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Apartment			06/27/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Expired	08/14/2018 12:00:00 AM	ADDRESS	34.0698	-118.29525	Plan check for power only. Service upgrade to 600A 12 units appartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61654	14041-20000-25754	7809 W ELLENBOGEN ST	91040	7	210B193   273	2552013032	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.27186	-118.30326	PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61655	15041-20000-21712	1101 S HARVARD BLVD 1-40	90006	10	129B193   631	5080021027	R3-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Apartment			07/09/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.05066	-118.30443	Full plan check for New appartment building 40 units	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61656	17041-20001-17303	7919 N MASON AVE	91306	3	189B109   566	2108019006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.21426	-118.57993	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on a SFD.10.4kW ungrounded system. (30) 295W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61657	15041-10000-07705	14624 W SHERMAN WAY	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.20102	-118.45165	replacement of fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61658	17041-30000-45492	5757 W WILSHIRE BLVD #700	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 only. Project site is a portion of the 7th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,264 sq. ft.Note: Building application has been generated under 17016-10000-31139. Electrical permit fees has been paid under 17041-90000-41077	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61659	14041-20000-02366	735 S FIGUEROA ST UNIT 120	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	PC FOR T24 ENERGY ONLY. NEW LIGHTING IN EXISTING RETAIL. TOTAL AREA 1327 SQ FT. WORK DONE FOR T-MOBIL, UNIT 120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61660	13041-10000-01818	1600 N VINE ST	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.1	-118.32647	EXISTING HIGH RISE. T24 FOR LOBBY PORTION ONLY. TOTAL AREA OF 3071 SQ FT.REPLACING LUMINAIRES WITH SIMILAR ENERGY SAVING MODELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61661	12041-10000-11568	9019 S AIRPORT BLVD	90045	11	093B169     5	4123018928	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	33.95367	-118.38613	"Employee parking lot lighting and guard booth power.  Load is less than 400A.  PLAN CHECK ONLY for Power.  Permit fees are under ""Inspection""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61662	17041-20000-40113	10962 W LE CONTE AVE	90024	5	135B149   560	4363017002	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.06346	-118.44754	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LEVEL 1  of an  (e) 2 story office building. 2790 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61663	11041-10000-17124	3470 W 6TH ST	90005	10	135B197  1033	5502029026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/12/2011 12:00:00 AM	PIN	34.06333997	-118.29761911	TI TO AN EXISTING 7-ELEVEN STORE.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61664	13041-20000-13653	2445 N CORRALITAS DR	90039	13	147A211   111	5440030008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.09829	-118.25296	PV1 FOR TWO STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 5.61 KW. 22 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61665	11041-10000-11693	19600 W PLUMMER ST	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.2426	-118.5602	New fire alarm system for an appartment Bldg. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61666	12041-10000-03435	6801 W HOLLYWOOD BLVD #257	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	ADDRESS	34.10229	-118.33907	TENANT IMPROVEMENTS TO EXISTING STARBUCKS.  Change to lighting and added receptacles.  NO Emergency lighting per applicant.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61667	15041-20000-18839	19143 W VICTORY BLVD Bldg 5	91335	3	180B121   534	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.18674	-118.55078	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10KW AC.  39-CS6P255 MODULES  AND SMA SB4000US AND SMA SB6000US. BUILDING  # 5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61668	11041-20000-06480	11922 W SAN VICENTE BLVD #3F	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			PC Approved	04/01/2011 12:00:00 AM	ADDRESS	34.0524	-118.47067	Plan check T24 Energy for retail store TI suite #3F.Note: Permit issued under 11041-20000-06513	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61669	17041-10000-28604	2029 W BLAKE AVE	90039	13	148-5A213  73	5442017001	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/14/2017 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.10243	-118.24364	PC for 600A 120/240V service upgrade. Installing new service equipment and two new panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61670	19041-10000-06983	10250 W SANTA MONICA BLVD S1650	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Issued	02/26/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Energy plan check for an existing storage room located in the mall. Scope includes new lighting and equipment with a total area of 335-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61671	19041-20000-16760	14119 W POLK ST	91342	7	225B153   200	2504011156	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM			PC Info Complete	05/06/2019 12:00:00 AM	ADDRESS	34.31526	-118.44146	Addition to (E) house of worship.  (2) new subpanels and associated wiring on (E) service.  Plan check for energy - 2,485 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61672	19041-30000-05772	590 N VERMONT AVE Suite 402	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			PC Info Complete	02/19/2019 12:00:00 AM	ADDRESS	34.08157	-118.2915	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 892 sq. ft.Note: Building application has been generated under 19016-30000-04114	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61673	12041-10000-00848	2410 W JEFFERSON BLVD	90018	10	120B189   724	5044031005	C2-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.02544	-118.32163	New 40 unit apartment building with unkown service size.   <<<<<Customer has a pre-printed check, fees are based on customers estimate.  Additional fees to be collected for Energy, etc to be around $23,000>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61674	14041-20000-17139	15301 W VENTURA BLVD BLDG E	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.15411	-118.46654	PC FOR T24 ENERGY ONLY.TI OF EXISTING OFFICE SPACES. NEW LIGHTING. PROJECT LOCATED IN BUILDING E. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61675	19041-20000-14637	3626 W MONON ST pv2	90027	4	151-5A205 193	5433026024	RD1.5-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Apartment			04/22/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Issued	07/19/2019 12:00:00 AM	ADDRESS	34.10841	-118.27262	PV2.  Install roof mounted PV system sized 3.8KW AC with (1) Tesla Powerwall ESS interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61676	17041-20001-04511	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.10158	-118.3062	Plan check for energy only. Interior TI of (E) restaurant. New lighting (incl. emergency). 2,862sqft.This supplemental 17041-20001-04511 to act as master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61677	19041-10000-07156	6572 N VAN NUYS BLVD	91401	6	180B149   468	2237013017	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Issued	02/28/2019 12:00:00 AM	ADDRESS	34.19035	-118.44844	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61678	19041-10000-12200	11723 W TERRA VISTA WAY	91342	7	216B169   141	2526026033	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Issued	04/04/2019 12:00:00 AM	ADDRESS	34.28506	-118.38628	PC FOR ROOF MOUNTED PV ON SFD.SYSTEM SIZE 8.12 KWDC / 7.0 KWACSCOPE INCLUDES 28 PANELS AND 28 MICRO INVERTERS  WITH SUBPANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61679	12041-10000-11754	11566 W DONA TERESA DR	91604	2	159B169   521	2381012001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.13101	-118.38564	New 13.44kw, rooftop photovoltaic system for an existing sfr.  New 225A service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61680	12041-10000-22577	7270 W MANCHESTER AVE	90045	11	096B157   625	4119026042	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Apartment			09/21/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.95959	-118.42143	NEW 6 STORY 260 UNITS APARTMENT BLDG WITH 3 LEVELS UNDERGROUND PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61681	17041-20000-42007	6429 N GENTRY AVE	91606	2	180B165   653	2322013036	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Issued	12/01/2017 12:00:00 AM	ADDRESS	34.18766	-118.39337	INSTALLATION OF ENERGY STORAGE SYSTEM 14KW TO EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61682	19041-10000-01056	3839 E SELIG PL	90031	1	136-5A227  45	5211020900	PF-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.0683	-118.1994	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61683	18041-10000-35806	801 S LOS ANGELES ST	90014	14	127-5A211 292	5145014001	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.04194	-118.25259	PLAN CHECK FOR TITLE 24 ONLY FOR A COFFEE SHOP. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS.  TOTAL AFFECTED AREA = 1560 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61684	18041-20000-35314	21331 W COSTANSO ST	91364	3	171B105   167	2167002037	(Q)C1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.16689	-118.59684	Plan check for a PV1 roof-mounted PV system. System size is 16.6 kWac and consists of (3) inverters, (58) modules, and (2) load centers.$0 permit fee per State Senate Bill SB 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61685	16041-10001-29672	1010 E JEFFERSON BLVD	90011	9	115-5A209  94	5114015045	(T)(Q)CM-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Apartment			05/11/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.01202	-118.258	CHANGES TO THE APPROVED SET OF PLAN INCLUDING DOWNGRADING THE SERVICE FROM 3000AMP TO THE 2000AMP SO THE SINGLE LINE DIAGAM AND FAULT CURRENT CALCULATIONS. CHANGES HAS SHOWED AS DELTA 5. PLAN CHECK ONLY(5/11/2017)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61686	12041-10000-08479	2259 N RONDA VISTA DR	90027	4	148-5A203 118	5433015010		Central			Y	1952.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	ADDRESS	34.10213	-118.27535	Rooftop photovoltaic system for a SFD, 6.87KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61687	15041-20002-39997	6858 N MAMMOTH AVE	91405	2	183B157   787	2216025051	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.19551	-118.43221	05/16/2016 Change to an approved set of plans. Changes have been made to reflect field installation. MSP has been upgraded to a 200-amp panel with a 175-amp main breaker.*****Previous Work Description*****Expedited plan check fee per customer request.  PV2. Install roof mounted PV system sized 13 kW. Interconnectd with main service panel.(40) SunPower 327W Modules(2) SMA inverters: SMA 7.7 and SMA 3.8	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61688	18041-20000-08453	1000 W WILSHIRE BLVD 17th Floor	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to the 17th floor corridors. Total lighting area = 1,181 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61689	19041-10000-10099	18781 W BRAEMORE ROAD	91326	12	216B121   229	2820016004	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.28968	-118.54229	(ePlan) New roof-mounted solar PV system 7.6 kW AC. Instal 37 modules, 37 power optomizers,  and 1 inverter. System conect to (E) 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61690	12041-20000-28774	13616 W RIVERSIDE DR	91423	2	168B157   322	2359020019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.15745	-118.42955	Enphase system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61691	13041-20001-29092	8451 W HILLSIDE AVE	90069	4	148-5A175 271	5558028037	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.10047	-118.37255	(((EXPEDITE FEES ONLY)))PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 24KW. 96 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61692	12041-10000-13318	601 W 5TH ST 10th floor	90071	9	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for energy and emergency lighting. Lobby and bathrrom on 10th floor of commercial highrise. Occupancy load is less than 99. 1142 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61693	17041-10000-01013	14701 W VENTURA BLVD	91403	4	166-5A149  17	2265001001	C2-1L, [Q]R3P-1, [Q]R3P-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.15183	-118.45322	Energy plan check for a commercial bank T.I total area 7650 SQ ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61694	18041-20001-14606	11676 W TUXFORD ST	91352	6	192B169   420	2632023048	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM			PC Approved	03/08/2019 12:00:00 AM	ADDRESS	34.22289	-118.38698	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE OF CIRCUIT BREAKER RATINGS, AND PANEL RATINGS.*ORIGINAL*Plan check for power and energy for new wearhouse and manufacturing building 1 story, core and shell for different tenant in the spaces. Total area: 27,155 sq ftB#18010-20000-00414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61695	19041-10001-22150	3420 N GREEN VISTA DR	91436	5	159B137   330	2287010064	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM			PC Approved	07/05/2019 12:00:00 AM	ADDRESS	34.1326	-118.4988	Expedite per applicant request.Plan check for a PV1 7.6KW AC / 6.4KW DC roofmounted system with (1) battery storage system, (1) load center, (1) inverter, (21) modules and optimizers interconnecting through the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61696	18041-20002-13877	7240 N HAYVENHURST PL	91406	6	186B137   239	2205010905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Issued	07/16/2018 12:00:00 AM	ADDRESS	34.20231	-118.49217	07-16-2018 Changes to an approved set of plans. Changes include addtional of 6 fire alarm devices. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61697	17041-10000-33580	407 N ARDMORE AVE	90004	13	138B193   162	5521023013	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	34.07789	-118.30254	Install new fire alarm system on a 3 story, 6 unit apartment build.; (1) FA panel, (44) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61698	12041-20001-25969	619 S GAFFEY ST	90731	15	015B197   403	7451035026	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	04/29/2013 12:00:00 AM	ADDRESS	33.73833	-118.29252	Full plan check 600A service. Title 24 done under 12041-20000-25969.Plan check for energy and emergency lighting. LIttle Caesar's Pizza. 1392 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61699	16041-10002-45356	2643 E 25TH ST BLDG 7	90058	14			M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.01546	-118.22426	Changes to permitted set of plans- outdoor luminaires for the silos and canopy; two sump pumps and storm water pump Title 24 compliance forms adjusted and service load calculations updated.All changes are labeled Bulletin 20 and clouded on the revised plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61700	17041-20000-02317	13557 W KITTRIDGE ST	91401	2	180B157   449	2329009048	R1-1, RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.19042	-118.42871	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (34) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61701	16041-10000-02086	1245 W WILSHIRE BLVD SUITE 680	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	FIRST GENERATION 2,583 SF MEDICAL OFFICE T.I. WITHIN EXISTING MEDICAL OFFICE BUILDING.PERFORMANCE METHOD IS USED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61702	12041-10000-24715	5900 W WILSHIRE BLVD # 750	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/16/2012 12:00:00 AM			PC Approved	10/16/2012 12:00:00 AM	ADDRESS	34.06237	-118.35809	RENOVATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61703	14041-20000-06927	1100 W WILSHIRE BLVD suite B	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.05228	-118.26384	add two pumps on generator.COMPLY WITH DEPARTMENT ORDER DEFFECTIVE DATE 12/13/2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61704	15041-20000-03543	6501 N QUAKERTOWN AVE	91367	3	180B113   659	2134037011	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.18849	-118.57014	PV1 SFD. TOTAL SYSTEM SIZE 7.7KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. USING INDEPENDENT POWER OPTIMIZERS. (22) 255W PV MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61705	13041-20005-06945	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/09/2014 12:00:00 AM			PC Approved	12/10/2014 12:00:00 AM	PIN	34.03245819	-118.45766562	Changes from previously approved plans.  Permit issued under 20000 PCIS #.  Addition of one outdoor building sign resulting in changes to title 24 compliance sheets.  Addition of kirk key interlock to give option for portable generator.*****Previous Description*****New multi-tenant buildling.  Service is being plan check on separate application.  However, this plan check will be required for service load sizing.  The building appears to  be multiple structures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61706	18041-20001-04334	8353 W GRAND VIEW DR	90046	4	148-5A175  22	5556019020	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2018 12:00:00 AM			PC Approved	03/08/2018 12:00:00 AM	ADDRESS	34.10318	-118.37269	expeditepv1install roofmounted pv system sized 7.6 with battery back up interconnected wiuth msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61707	14041-20000-16532	6025 N VALLEY CIRCLE BLVD	91367	3	177B085   272	2032013031	(T)RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Issued	06/19/2014 12:00:00 AM	ADDRESS	34.18015	-118.65624	Remodeling of restrooms in single-story synagogue.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61708	14041-20000-03784	16025 W CIRCLE DIAMOND ROAD PV1	91342	7	228B141    66	2582033021	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.32431	-118.48038	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL.6.75 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS, WITH (27) trina SOLAR #cs6p-250px, (27) OP300-MV, (1)6000A-US-ZB-U SOLAREDGE INVERTERS,	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61709	15041-20000-42574	14006 W LEADWELL ST	91405	2	186B153   592	2216001008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.20374	-118.43811	Plan check for a PV1 roof-mounted PV system. A 3 kWac system addition is being made to a 5 kWac existing system. Addition consists of (1) inverter, (9) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61710	18041-10000-19649	5684 E YORK BLVD	90042	14	154-5A229 114	5478035002	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.11876	-118.19402	TI IN AN EXTING RESTAURANT. PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61711	17041-10000-03490	621 S WESTERN AVE 100-A	90005	10	135B193   955	5503031019	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	03/06/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.0628	-118.30928	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COOKING KITCHEN FOR OUTDOOR RESTAURANT WITHIN EXISTING SHOPPING MALL. TOTAL AFFECTED AREA IS 567 SQ. FT. B#16016-10000-26621	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61712	14041-20000-34204	328 S LA BREA AVE	90036	4	135B181   261	5507008021	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.06807	-118.34383	Title 24 plan check only.  Total area = 1600 sq. ft.T.I. to existing commercial space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61713	12041-10001-18040	1160 W HARRY BRIDGES BLVD	90744	15	027B201   208	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Closed	02/07/2014 12:00:00 AM	PIN	33.77018478	-118.27675111	PLAN CHECK FIRE ALARM SYSTEM FOR NEW 1-STORY DRIVER SERVICE BUILDING FOR THE PORT OF LA (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61714	16041-10000-43268	1560 E 20TH ST	90011	9	118-5A213  62	5118001027	M1-1, P-1, [T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.01938	-118.24501	PC for enrgy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total sqft: 116700.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61715	17041-20000-17379	4667 N MORRO DR	91364	3	168A109    44	2172003003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Refund in Progress	07/14/2017 12:00:00 AM	ADDRESS	34.15564	-118.59089	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61716	17041-20000-27763	13007 W SHERMAN WAY	91605	2	183B161     4	2327015019	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.20136	-118.41649	Replacement of 600A 480V 3ph-3w HVAC MCC panel.  All reconnected utilization equipment existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61717	19041-10000-33468	9472 N SANDUSKY AVE	91331	6	198B153   187	2642017001	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.24208	-118.43287	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 29 MODULES (Q-PEAK 305), POWER OPTIMIZERS (SE P320)WITH 1 CENTRAL INVERTER SE7600H-US. SYSTEM SIZE IS 8.85 KWdc AND 7.6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61718	13041-10000-33007	19041 W CELTIC ST	91326	12	210B121   615	2718011001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Verifications in Progress	03/14/2014 12:00:00 AM	ADDRESS	34.2693	-118.54777	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 9.25KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(37) TRINA SOLAR # TSM-250(37) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A(1) SOLAREDGE # SE5000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61719	16041-20000-11027	5455 S INGLEWOOD BLVD	90230	11	105B161   453	4220019033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Apartment			04/11/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	33.98529	-118.40735	NEW 3-STORY 13 UNIT APARTMENT OVER BASEMENT GARAGE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61720	15041-10000-40497	645 N TUALLITAN ROAD	90049	11	138B137   631	4494010003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.07123	-118.48491	PV1, INSTALL A 16350 W DC SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(2) INVERTERS: FRONIUS USA PRIMO7.6 240V(50) MODULES: SUNPOWER SPR-E20-327 W	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61721	19041-20000-15599	2925 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Closed	11/08/2021 12:00:00 AM	ADDRESS	34.1041	-118.24373	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61722	15041-20000-04254	1450 N GENESEE AVE	90046	4	147B177  1047	5551023013	R1-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.09758	-118.35804	PV1Install a roof-mounted solar array on a SFD and detached garage. Interconnect with a 225A MSP (w/200A main).System size: 10.08kW. Ungrounded system.(42) EnPhase M250 microinverters with (42) 275W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61723	15041-10000-35040	2119 E 25TH ST	90058	14	117A217    13	5167007020	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.01491	-118.2334	Energy plan check for removing HID light fixture and replace with LED fixture in a commercial building, warehouse.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61724	17041-20000-45388	10131 N LEMONA AVE	91345	7	204B149   346	2660018005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.25471	-118.4588	Plan check for solar pv system w/roof-mounted array on SFD.6kW ungrounded system. (20) 305W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61725	13041-10000-11779	3535 S NORMANDIE AVE	90018	8	120B193  1025	5041010001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/09/2013 12:00:00 AM	PIN	34.02396201	-118.30043093	pc for energy only for circle K convenience store. TI to existing building. inspector sent them back for PC because 13041 10000 08321 (existing permit) was missing T24 calculations.less than 400A and no emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61726	14041-10000-06583	646 S GIBBONS ST	90031	14	135A219    24	5410012017	M3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.06608	-118.22384	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR FIRE DAMAGED BUILDING. < 400 NEW CONNECTED LOAD. NO CHANGE IN OCCUPANCY. 5315 SQFT, EMERGENCY LIGHTING.BUILDING P# 14016-20000-00153 : REPAIR OF ROOF FRAMING;  REBUILT INTERIOR OFFICES & (E) BATHROOMS WITH TWO (N) ADA BATHROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61727	12041-10000-03794	7315 N FIGUEROA ST BUILDING A	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.13628	-118.18852	New 1 story commercial Building A core and shell on an existing lot.  Power and energy.  (Building B under a separate application 12041-10000-03784)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61728	19041-20001-47556	755 N STRADELLA ROAD	90077	5	141B149   145	4369022003	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM			PC Approved	12/03/2019 12:00:00 AM	ADDRESS	34.08265	-118.45298	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CLOUDED DELTA 3 CHANGES ONLY. CHANGE MADE TO SINGLE LINE, CHANGE TO PANEL GROUND SIZES, MATERIAL AND ARRANGEMENT TO MATCH FIELD INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61729	16041-10000-02948	3530 W WILSHIRE BLVD 1500	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.06154	-118.30122	T-24,  TENANT IMPROVEMENT IN EXISTING OFFICE SPACE INSIDE A HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 13580.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61730	19041-10000-32988	10465 W ARMINTA ST	91352	2	189B177   368	2407016028	M1-1, MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.21419	-118.35948	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61731	14041-10000-11033	1111 W WILSHIRE BLVD	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM			Corrections Issued	04/28/2014 12:00:00 AM	ADDRESS	34.05259	-118.26348	PC FOR  ENERGY ONLY.T.I. TO EXISTING OFFICE SPACE. DEMO OF NON-STRUCTURAL PARTITIONS, CONSTRUCTION OF NEW NON-RATED PARTITIONS, NEW DOORS & CEILING GRID. (300 S.F.)BUILDING # 14016-10000-08005.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61732	13041-20000-23792	460 N EZRA ST	90063	14	127-5A229 112	5178024005	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2038.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.04284	-118.19453	PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW USING 15 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61733	12041-10000-24987	5450 S LINCOLN BLVD	90094	11	102B157   293	4211022004	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Public Safety Only			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	33.97348	-118.43093	New fire alarm system for a medical plaza.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61734	14041-20000-17204	2652 E 7TH ST	90023	14	123A223   239	5189013006	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2047.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.03083	-118.21411	3.85KW PV1 roof-mounted system including (14) Sunedison 275w modules and Enphase M250 Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61735	19041-10000-27498	7241 N LANKERSHIM BLVD	91605	2	186B169   965	2317019032	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.20251	-118.38798	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61736	13041-10000-01562	801 E 7TH ST	90021	14	126A213   287	5147028039	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Closed	11/12/2013 12:00:00 AM	ADDRESS	34.03955	-118.24481	"existing 600a panelboard12016 10000 23210T.I. RETAIL AT FIRST FLOOR ENTIRE FLOOR;  CREATE 17 RETAIL TENANTS. (PC TO VERIFY OCCUPANT LOAD). ""COMPLY WITH DEPARTMENT ORDER effective date 02/14/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61737	12041-20000-03706	12326 W RIVERSIDE DR	91607	2	168B165   537	2356034011	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.15745	-118.40171	NEW SERVICE TO EXISTING BUILDING SCHOOL/TEMPLE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61738	18041-10000-32009	7317 N HASKELL AVE	91406	6	186B141   858	2206037111	R3-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.2033	-118.47511	NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL BUILDING. CONSIST OF 94 MODULES (JAP72S01-330/SC) AND 2 INVERTERS 12K EACH (SYMO 12.0-3).  SYSTEM SIZE IS 31.02KWdc and 24KWac. SCOPE INCLUDES NEW LOAD CENTER AT 100AMP - 3PHASE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61739	16041-10000-23251	1445 N LA BREA AVE	90028	4	147B181   724	5548017400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.09739	-118.34438	PC FOR POWER AND ENERY. MEDICAL OFFICES (URGENT CARE) CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE(ERGENT CARE) TOTAL AREA 2140 SQ FT.B#16016-10000-15336.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61740	12041-10001-08076	1501 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00, 1910.00	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.09822	-118.32695	PLAN CHECK REVISION TO APPROVED PLANS. REVISION CLOUDED DELTA 8. NEW PANEL, TRANSFORMER, AND BRANCH CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61741	19041-20000-22688	9760 N ABREGO CT LOT 13	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.24766	-118.45048	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61742	11041-10008-27025	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.04661	-118.2324	(((7/10/2014 Supplemental app for power and energy)))PROPOSED 6-STORIES MIXED USE BUILDING: RETAIL;APTS;LIVE/WORK UNITS;OFFICES;GARAGE;PORTION OF THE BUILDING IS 5-STORIES, TYPE IIIA, APTS OVER 1-STORY TYPE I GARAGE/RETAIL/OFFICE.OTHER PORTION IS 3-STORIES TYPE IIIA APTS OVER 3-STORIES TYPE INOTE; PRELIM SUBMITTAL PLAN CHK FEES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61743	19041-20001-32647	7200 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1014.00	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			PC Approved	10/15/2019 12:00:00 AM	ADDRESS	34.24842	-118.28878	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61744	19041-10001-40760	8485 N PENFIELD AVE	91306	3	192B113   232	2782010127	(T)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Issued	10/23/2019 12:00:00 AM	ADDRESS	34.22438	-118.569	PLAN CHECK FOR A MODIFICATION OF A PV1 ROOF MOUNTED SYSTEM. SCOPE INCLUDES ADDING (5) MODULES, MODIFY THE SINGLE LINE AND FLOOR PLAN. ALL CHANGES UNDER DELTA-1 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61745	16041-10000-39622	1318 E 7TH ST Ste 100	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.03608	-118.24052	Energy plan check for a retail store (A +R Showroom). Scope includes new lighting and receptacles; total area is 6805 SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61746	18041-20000-16402	14900 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.29425	-118.45498	Plan check for PV roof mounted system, system size:3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61747	17041-10000-08381	2029 S CENTURY PARK EAST #N2910	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for title 24 only in existing space T.I office space. Total area: 3880 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61748	19041-10000-05330	21431 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.25739	-118.59841	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61749	16041-10000-13926	818 E NOWITA PL	90291	11	108B145   565	4241019034	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM			Corrections Issued	04/21/2016 12:00:00 AM	ADDRESS	33.99393	-118.46007	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (32)MODULES-SOLARCITY STANDARD(1)INVERTER-FRONIUS #PRIMO 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61750	18041-20000-46593	5316 N OVERING DR	91367	3	171B089   168	2047018014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2018 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.16686	-118.64736	permit fee $0.00 by state senate bill no. 1222Plan check for PV roof mounted system, system size: 17.92kW  DC, 13.6kW AC with 56 PV modules and 2 inverters(6.0kW and 7.6kW).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61751	12041-10000-29401	11444 W OLYMPIC BLVD	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.03654	-118.44363	FUEL CELL INSTALL OUTSIDE FOR HIRISE 10TH FLOOR.  ONE BLOOMENERGY ES-5710 OUTDOOR NATURAL GAS CLEAN ENERGY UNIT WITH UNINTERRUPTIBLE POWE RMODULE (UPM). NEW CLEAN ENERGY SERVER IS LOCATED IN THE PRIVATE ALLEY WAY. CLEAN ENERGY UNIT IS SUPORTED ON PRECAST STRUCTURAL CONCRETE PAD AND THE UPM IS SUPPORTED ON POURED IN PLACE CONCRETE UNDERGROUND PIPING, CONDUIT ROUTING AND NEW CONCRETE PAD FOR AN ELECTRICAL AND WATER DISTRIBUTION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61752	16041-10000-42684	10250 W SANTA MONICA BLVD # 2800	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time tenant ""California Pizza Kitchen"" Ste. 2800.  Install 112.5KVA Xrfmr, new panels and its circuits, total effected area: 5,367 sq.ft.*New demand load is approx 127 A to MS ELA33"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61753	16041-20001-30654	11221 N RAVENNA LANE	91326	12	210B109   498	2701051068	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM			PC Approved	09/28/2016 12:00:00 AM	ADDRESS	34.27518	-118.58496	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.2 KW. (SUBMITTED PER APPLICANTS REQUEST)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61754	11041-10000-25245	3124 N NICADA DR	90077	5	159B149   369	4379035192	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	ADDRESS	34.13054	-118.44877	New 5.13KW roof-top photovoltaic system for a single family residence.  One inverter with 27 PV panels and a new sub-panel with new circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61755	17041-20000-40867	12656 N RALSTON AVE	91342	7	219B149    57	2506032030	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.30038	-118.45635	PV1.  Install roof mounted PV system sized 11.4kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61756	19041-10000-39364	4648 N ARRIBA DR	91356	3	168B121   321	2176025024	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.15576	-118.54315	PLAN CHECK FOR ROOF MOUNTED 11.4KVA PV1 SYSTEM CONSISTING OF 29 WITH P400 OPTIMIZERS CONNECTED TO NEW 225A SERVICE 225A SERVICE UNDER SEPARAGTE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61757	13041-20000-35066	8610 S SEPULVEDA BLVD	90045	11	096B165   633	4123003001	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	33.9595	-118.39597	T24 FOR FOUR BATHROOMS AND ENTRY LOBBY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61758	16041-20000-17384	510 S ARDMORE AVE	90020	10	135B193   700	5502017019	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.06499	-118.30141	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 48KW INTERCONNECTED WITH MSP.Note: Fee $0 due to SB1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61759	12041-10000-13080	5233 W EL MIRADOR DR	90008	8	114B177     8	5029023008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.01223	-118.35863	Plan check for new 9.18 KW roof mounted Photovoltaic System. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61760	17041-20000-01206	1338 N GORDON ST	90028	13	147A191   187	5545014035	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			01/13/2017 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.09564	-118.31997	Plan check for a fire alarm system for a 44-unit apartment building. System consists of (1) FACP, (1) annunciator, and (116) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61761	18041-10000-43353	6800 S CENTINELA AVE	90230	11	105B165   426	4220014022	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Info Complete	11/19/2018 12:00:00 AM	ADDRESS	33.98417	-118.40209	T-24, PC for energy only. Change of use from factory / warehouse to office and storage, and interior remodel. Scope includes new lights and receptacles.  Total affected area is 2616 Sq. Ft. b#18016-10000-26175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61762	16041-20000-05828	10748 W RIVERSIDE DR	91602	4	165B177    92	2423005013	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			02/18/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.15208	-118.36528	PLANCHECK FOR POWER AND ENERGY. NEW 13-UNIT APARTMENT BUILDING WITH ONE LEVEL SUBTERRANEAN PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61763	14041-10000-13033	1935 E 16TH ST	90021	14	120A215   182	5167019034	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Closed	06/03/2014 12:00:00 AM	PIN	34.02215904	-118.23835393	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLOURESCENT FIXTURES, TOTAL AREA 21138 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61764	17041-10000-33128	801 N EVERGREEN AVE	90033	14	129A227   195	5178009028	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.04764	-118.19799	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 8050 SQ.FT (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61765	16041-10000-03710	1072 W 39TH PL	90037	8	117B197  1014	5037021002	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Expired	03/12/2018 12:00:00 AM	ADDRESS	34.01402	-118.29388	PV1, ROOF MOUNTED SOLAR SYSTEM TO A TRIPLEX BUILDING. (17) MODULES AND (1) 3.6 KW INVERTER. TOTAL SIZE IS 3.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61766	13041-10000-29792	515 S FLOWER ST 32ND FLR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLAN CHECK FOR T24 ENERYGY ONLY. HIGH RISE. 32ND FLOOR. OFFICES. 2053 SQFT, EMERGENCY LIGTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61767	13041-10000-32974	221 N FIGUEROA ST	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Public Safety Only			11/25/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Issued	03/04/2014 12:00:00 AM	ADDRESS	34.05882	-118.25099	FIRE WARNING SYSTEM REPLACEMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61768	15041-10000-39968	11800 W WILSHIRE BLVD 2ND FL	90025	11	129B145   804	4263007123	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM			PC Approved	12/14/2015 12:00:00 AM	ADDRESS	34.04771	-118.46271	ADDITION OF ADJACENT AREA  TO EXISTING INFUSION ROOM/CLINIC AT THE ANGELES CLINICPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61769	19041-10000-07544	11750 W SAN VICENTE BLVD	90049	11	129B145    93	4265018017	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.0529	-118.46785	PC FOR TITLE 24 RETAIL SPACE SCOPE INCLUDES NEW LGIHTING AND EQUIPMENT OF 1865 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61770	19041-20002-19951	112 N JUNE ST	90004	4	138B185   211	5515003007	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM			PC Approved	11/06/2019 12:00:00 AM	ADDRESS	34.07442	-118.33415	11/6/19CHANGES TO APPROVED SET CHANGES TO SYSTEM SIZE.<<<PV1.  Install 12.73 kW DC / 10.82 kW AC roof mounted grid tied PV system.  (38) modules with microinverters.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61771	18041-20000-43924	14348 W ROBLAR PL	91423	4	165A151   172	2266011022	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.14639	-118.44656	Plan check for a PV1 roof-mounted PV system. System size is 6 kWdc/4.56 kWac and consists of (19) modules, (19) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61772	15041-20001-29183	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.05069	-118.24861	[5/12/16 changes to approved T24 only plancheck.  removing 1 E/R fixture and adding 2 Led1 fixture. changes are clouded. plancheck only.]]]]TI for a restaurant. PC for energy only. Total area 584 sq. ft**** corrected total area after verification is about 800sq.ft.  refer to plan for accurate number****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61773	19041-10000-46806	3040 W BEVERLY BLVD	90057	13	138A201   289	5155003022	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Issued	11/14/2019 12:00:00 AM	ADDRESS	34.07161	-118.28216	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61774	14041-20000-19409	23325 S MALTBY PL	90710	15	042B193   103	7438003004	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	33.81384	-118.30464	PV1INSTALL ROOF MOUNTED OV SYSTEM SIZED 3.36KW INTERCONNECTED WITH MAIN SERVICE PANEL.(14) ENPHASE M250 MICROINVERTERS(14) SOLAR WORLD SW280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61775	19041-20001-17363	4877 W 63RD ST	90056	11	105B177   449	4002002012	R1-1XL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	33.98217	-118.36389	PLAN CHECK ONLY, SUPPLEMENTAL CHANGES TO APPROVED SET. CHANGE IN PV MODULE MODEL TO CANADIAN SOLAR CS1H-325MS AND MODULE QUANTITY DECREASED BY 2. MINOR CHANGE IN SYSTEM SIZE BY 10 WATTS LOWER, ROOF PLAN LAYOUT ALTERED, AND SINGLE LINE DIAGRAM CHANGED MODULE MODEL AND PV OPTIMIZER MODEL. CLOUDED CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61776	18041-20000-26587	4203 W JEFFERSON BLVD	90016	10	120B181   692	5050025058	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.0257	-118.34196	Plan check for power and energy for core and shell of existing building service upgrade to 800A 240/120 Volt 3 Phase 4W. Total area: 460 sq ft. B#18016-30000-19702	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61777	19041-10002-34200	11035 N LEOLANG AVE	91040	7	210B193   576	2552014008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM			PC Approved	10/03/2019 12:00:00 AM	ADDRESS	34.2698	-118.3064	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS (DELTA 1) - CHANGES INCLUDE RELOCATION OF EQUIPMENT FROM GARAGE TO SIDE OF SFD AND REMOVAL OF DISCONNECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61778	19041-10000-17867	4515 N EAGLE ROCK BLVD	90041	14	157-5A221  80	5473037007	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	07/02/2021 12:00:00 AM	ADDRESS	34.12659	-118.219	PC FOR POWER AND ENERGY(LOT 27-32). SCOPE INCLUDES A NEW800A SERVICE FOR 6 SFD AND COMMERCIAL SPACES. TOTAL AFFECTED AREA IS 42218 SQ. FT. ENERGY PC UNDER MASTER 19041-10000-17858.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61779	13041-10000-17423	4173 N SUNSWEPT DR	91604	2	162B161   326	2384023040	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.14207	-118.40635	PV 1 .  Residential. roof mounted, solar installation. 36  micro inverters enphase m215. Tsm-240w 36 modules. non-standard plan. 8.65 kw DC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61780	10041-10000-04450	8027 N LANKERSHIM BLVD	91605	6	189B169   156	2310007010	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.00	Electrical	Electrical	Commercial			03/11/2010 12:00:00 AM	03/11/2010 12:00:00 AM		Permit Finaled	06/22/2010 12:00:00 AM	ADDRESS	34.21664	-118.38805	CHANGE OF USE 991 SQ FT PORTION TO SUBWAY RESTAURANT & T.I.plan chk is fior title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61781	19041-10000-33944	1813-1821 S PANDORA AVE	90025	5	132B157   809	4317002026	RD1.5-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Info Complete	09/27/2019 12:00:00 AM	ADDRESS	34.05623	-118.42457	PLAN CHECK FOR A NEW METHANE MITIGATION-GAS DETECTION SYSTEM IN A APPARTMENT COMPLEX. SCOPE INCLUDES NEW PANELS AND 34 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61782	12041-10000-23481	2342 S FREY AVE	90291	11	106-5A147 186	4228007008	R1-1	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2012 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	33.98649	-118.46019	INSTALLINY ON THE ROOF OF A SFD, A 5.4KW PHOTOVOLTAIC SYSTEM USING MICROINVERETRS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61783	17041-10001-39551	1438 W 254TH ST	90710	15	036B193   526	7410006044	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Apartment			11/01/2017 12:00:00 AM			Reviewed by Supervisor	11/09/2017 12:00:00 AM	ADDRESS	33.79368	-118.30248	*fee expedited per applicantInstall new PV1, rooftop solar system 3kW AC on a SFD, (7) modules and (1) inverter. Also install (1) ESS Tesla powerwall 13.5 kWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61784	17041-20001-16711	11134 N ENCINO AVE	91344	12	210B129   247	2711011023	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	ADDRESS	34.27315	-118.51512	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (43) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61785	16041-20000-20154	7886 N VAN NUYS BLVD	91402	6	189B149   635	2212028018	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Issued	11/01/2016 12:00:00 AM	ADDRESS	34.2144	-118.44789	Replacement of (E) fire alarm panel Silent Knight 5207 with Silent Knight 5808 FACP.  Additional notification applicance devices and connection of duct detectors.Note: incorrect conductor resistance value on plans - voltage drop still within device tolerance levels (16V low operating range) with proper resistance value considered.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61786	18041-20000-44478	8951 W APPIAN WAY	90046	4	150B169  1057	5563027005	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.10652	-118.38501	Plan check for PV roof mounted install in addition to existing PV system, addtion of 6 PV modules to existing system. New total system size: 4.23kW DC, 3.0kW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61787	18041-10002-08139	2833 S WIGTOWN ROAD	90064	5	126B161   581	4318018024	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.03816	-118.41265	CHANGES TO APPROVED SET OF PLANS CHANGES INCLUDE ADDITION OF NEW DISCONNECTS FOR BATTERIES INSTALLED IN GARAGE AREA CHANGES TO AN APPROVED SET OF PLANS. SHEET 2 IS NOW REFLECTING PREVIOUSLY APPROVED AC DISCONNECTS. _________________________________________PC FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW ENERGY STORAGE SYSTEMS AND LOAD CENTER. TOTAL SYSTEM SIZE IS 27KWH/14KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61788	19041-20000-32379	12236 W GORHAM AVE	90049	11	129B141   475	4264012007	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.04776	-118.47351	PV1.  Install 8.68 kW roof mounted grid tied PV system.  (28) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61789	14041-20000-18103	12644 N ADELPHIA AVE	91340	7	219B157   134	2513026004	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.29963	-118.42299	PV1.  Install 4.95 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61790	14041-20000-11179	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.08363	-118.32191	REPLACE TRANSFORMER AND SWITCHBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61791	13041-20000-29122	10816 N REDMONT AVE	91042	7	207B197   372	2566011048	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.26557	-118.29297	new 6kw pv system using enphase M215.  rooftop.  permit for the service upgrade is on a separate permit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61792	18041-20000-03600	1135 N MANSFIELD AVE FLR 2	90038	4	144B181   376	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Info Complete	02/01/2018 12:00:00 AM	ADDRESS	34.0918	-118.34057	PLAN CHECK FOR TITLE 24 PLAN CHECK FOR -OFFICE TI- TOTAL AFFECTED AREA = 8985 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61793	15041-20000-29400	8039 N CEDROS AVE	91402	6	189B149   191	2210016004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Refund in Progress	08/31/2016 12:00:00 AM	ADDRESS	34.21719	-118.45367	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (26) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61794	14041-20000-01865	5865 N HILLVIEW PARK AVE	91401	2	174B157    59	2343020015	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.17701	-118.42642	pv1 single family dwelling. total system size 13.6kw ac using 59 modules and 3 transformerless inverters nonstandard plan.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61795	14041-20001-24778	12136 W MARSHALL ST	90230	11	108B161   714	4221017029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	33.99028	-118.41618	$0 submittal fee is due to Senate Bill SB-1222.Modification to approved set.  Change of some module models and derating of main breaker from 200A to 175A.  (((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(17) CANADIAN SOLAR -250P(1) SOLAR EDGE INVERTER WITH POWER OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61796	18041-20000-25032	1670 W BEVERLY BLVD	90026	13	135A207   236	5153012023	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.06416	-118.26523	First-time tenant to common area, outdoor lighting commercial office space.  Plan check for power and energy. Total area: 1905 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61797	15041-20000-28381	14810 W NEEDLES ST	91343	7	201B149   445	2650011014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Expired	09/22/2017 12:00:00 AM	ADDRESS	34.24707	-118.45472	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61798	10041-20000-19786	9545 N RESEDA BLVD #17	91324	12	207B133   507	2695002002	(T)(Q)C2-1VL, C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	08/26/2011 12:00:00 AM	ADDRESS	34.2439	-118.53634	energy plan check bounce boba loft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61799	16041-10001-11990	5858 N SHOUP AVE	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.17705	-118.6144	Changes to approved set of plans. Reconfiguration and addition of new devices. New annunciator. ((((New F.A. installation inside a recreation center.  (1) F.A. panel    (2) Ann. Panel     (92) devices.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61800	13041-10002-10048	5115 W WILSHIRE BLVD UNIT G	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.06233	-118.34134	CHANGES TO APPROVED SET OF PLANS. PLAN CHECK FOR BOTH ENERGY AND POWER. CHANGES TO POWER PLAN AND BOTH PANELS.[[[T24 ONLY WAS  PLAN CHECKED UNDER 10001, POWER PC WAS REQUIRED.]]]]Not a high rise building per building permitTHE PC # IS VALID FOR BOTH PLAN CHECK AND PERMIT.PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT COFFEE BEAN. 2007 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61801	16041-10000-40363	19129 W LEMAY ST	91335	3	180B121   218	2129019029	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.19149	-118.55015	PV, INSTALL NEW 3.8 KW DC ROOF-MOUNTED SOLAR SYSTEM, ON A SINGLE FAMILY HOUSE.(15) MODULES: HANWA Q-CELL. Q PLUS-G4 280 W(1) INVERTER: SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61802	17041-20000-17024	1602 N TAPER AVE	90731	15	024B197   348	7442017019	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	33.75946	-118.29814	Plan check for a PV1 roof-mounted PV system. System size is 6.8 kWac and consists of (27) micro-inverters, (27) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61803	13041-10000-11603	11100 W SANTA MONICA BLVD 10TH FLOOR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.04726	-118.44465	13041-10000-11603PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. COMMERCIAL HIGH RISE TENANT IMPROVEMENT (GENEARTOR). SCOPE OF WORK < 400A. REMINDER: ALL TITLE 24 PERMITS SHALL BE OBTAINED THROUGHT THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61804	17041-20001-22682	3530 W WILSHIRE BLVD	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.06154	-118.30122	7/31/2018changes to an approved set of plans.  changes to reduce system size to 180KW AC with line side tap.  (688) phono solar 325W(3) yaskawa solectria 60KWThis is plan check only.(((Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,054) modules, and (1) load center on parking structure. Note: Permit Fees $0 Due to SB 1222 Note: Building application has been generated under 17014-30000-03172)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61805	17041-20000-34747	13113 W VAN NUYS BLVD unit b	91331	7	210B161   744	2535018026	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.26875	-118.41881	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61806	13041-10001-23043	14615 W OXNARD ST	91411	6	177A151    96	2241026901	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Closed	06/13/2019 12:00:00 AM	ADDRESS	34.17955	-118.45137	PC FOR Changes to approved set UNDER DELTA 1,3,4 AND 5.SCOPE INCLUDES : REMOVING ADDITION AND UPGRANDING OF PANELSUPDATING CIRCUITS.CHANGES TO LUMINAIRES INSTALLED AND REVISION TO TITLE - 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61807	18041-10001-35294	6614-6624 S BROADWAY	90003	9	102B201   124	6012002026	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.10	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/23/2019 12:00:00 AM	ADDRESS	33.97934	-118.2781	PLAN CHECK ONLY. CHANGES TO APPROVED SET TO MATCH EXISTING CONDITIONS PER INSPECTOR'S REQUEST. CHANGES TO UPDATE SERVICE SIZE TO 800A  AND REVISE THE SINGLE LINE DIAGRAM. ALL LOADS ON PANEL F ARE RELOCATED TO PANELS B AND C. CHANGES TO LIGHTING WITH UPDATED T-24. ALL CHANGES ARE CLOUDED UNDER DELTA 1.CAHNGE OF ENGINEER TO MR. JOSE PEREZ	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61808	13041-10000-35626	947 S TIVERTON AVE	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			Reviewed by Supervisor	05/01/2014 12:00:00 AM	ADDRESS	34.06246	-118.44303	pc for power only. addition of emergency generator and panels (...) modify address to show where work is being done13016-30-13706 description: CHANGE OF USE OF (E) 14-STORY WITH 2-LEVEL SUBTERRANEAN PARKING TYPE 1 BUILDING FROM APARTMENT HOTEL TO RESIDENTIAL CARE FACILITY FOR THE ELDERLY (RCFE ) . ALSO, REMODEL EXIT CORRIDORS AND PROVIDE ADDITIONAL HANDRAILS IN THE STAIRWAYS .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61809	19041-30000-05147	2000 S AVENUE OF THE STARS #550N	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for Title 24 only. Project site is the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,750 sq. ft.Note: Building permit has been issued under 18016-20000-32655	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61810	12041-20000-23753	4600 W COLORADO BLVD	90039	13	162B205   273	5593018903	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.14094	-118.27314	Remove old motor loads and add new 150hp motor loads for water pumps.  Non-classified area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61811	13041-10001-36081	928 S BROADWAY	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/01/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Expired	12/22/2017 12:00:00 AM	ADDRESS	34.04154	-118.25658	(((((   10-01-2015   m.z.    ADDITION OF 100 HP FLUID COOLER AND 10 HP PUMP. ON THE ROOF FOR THE GEN SET COOLING SYSTEM )))))pc for power and energy. generator installed. methane zone13010-10000-02211: PROPOSED 9-STORY TYPE I  AND TYPE III-A  APARTMENTS OVER TYPE I GARAGE, RETAIL AND RESIDENTIAL (2 LEVELS ABOVE GRADE AND 4 BASEMENT LEVELS)PDPP   1 of  2 (70% w/ complete architactural, zoning, ADA, Green Building Plan Check.  NO Structural) Building Fire/Life Safety P.C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61812	14041-20001-01881	14802 W MORRISON ST	91403	4	169-5A149  65	2263029035	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	02/07/2014 12:00:00 AM	ADDRESS	34.16021	-118.45545	(((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61813	16041-10001-27929	2425 E MALABAR ST	90033	14	130-5A225 327	5177021019	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	Apartment			08/09/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.05005	-118.20463	void<<<PV, INSTALL 2.6 KW DC ROOF-MOUNTED SOLAR ARRAY on a single family house.(10) modules: canadian solar csp6p-260(1) inverter: solaredge SE3000A-US>>>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61814	16041-20000-17079	1414 S SANTEE ST	90015	14	124-5A209 303	5133019016	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.03377	-118.25922	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISTING HID FIXTURES REPLACING WITH LED FIXTURES.  TOTAL SQUARE FOOTAGE 4536.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61815	19041-10000-03226	5217 W WILSHIRE BLVD	90036	4	135B181   922	5507023018	[Q]C4-2-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.06238	-118.34347	PC t-24 only for CHANGE OF USE OF 1ST FLOOR RETAIL STORE TO TEA HOUSE. scope of work area 1130 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61816	13041-10000-16314	401 WORLD WAY	90045	11	090B161    37	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	33.94281	-118.40686	permit to be pulled at EPC counter only. PC FOR ENERGY ONLY. PARKING  UPGRADES. LAX PS401 (elevator upgrades for priority II, III, and IV units)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61817	16041-10000-41993	1810 W SLAUSON AVE	90047	8	108B193  1356	6001001025	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.98802	-118.31001	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 47880 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61818	18041-20000-03145	19118 W MARILLA ST	91324	12	201B121   408	2762006012	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.24716	-118.55032	Plan check of the addition of (1) Tesla PowerWall to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61819	16041-30000-17211	4040 N BECK AVE	91604	2	162B169   391	2368023058	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.14113	-118.38319	Plan check for 600-amp service upgrade for a single-family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61820	17041-10000-03497	7703 W WENTWORTH ST	91042	7	208-5A195  59	2552024041	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM			Corrections Issued	02/02/2017 12:00:00 AM	ADDRESS	34.26701	-118.30038	PC for a PV system on a single family home. Roof mounted solar system. System size of 7.6 KW, (36) Modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61821	14041-20000-28112	9423 N RESEDA BLVD Unit # A	91324	12	198B125   467	2763035025	(Q)R3-1, C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.24178	-118.53643	T.I. for (e) 1st floor retail space(2,225 sq ft).  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61822	16041-10000-37502	19928 W COMMUNITY ST	91306	3	192B113   451	2782009081	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	02/25/2017 12:00:00 AM	ADDRESS	34.22199	-118.56762	PV, INSTALL NEW 7.0KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(20) MODULES: SUNPOWER SPR-320-327W(1) INVETER:  SMA SUNNY BOY SB 7000TL-US-22(240)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61823	16041-20000-39669	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM			PC Info Complete	11/08/2016 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for power only. Replace (7) old/existing panels with new panels of like/same rating and in same locations. Reconnect existing feeders and branch circuits. No new load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61824	13041-10000-03932	8445 W MELROSE PL	90069	5	141B173   420	5528001032	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM			PC Approved	02/19/2013 12:00:00 AM	ADDRESS	34.08375	-118.37476	TI OF CURRENT RETAIL SPACE TO NEW RETAIL SPACE. TTOAL AREA 3070 SQ FT. PC FOR T24 ONLY. PERMIT TO BE ISSUED BY PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61825	19041-10000-22038	711 N CHESTNUT AVE	90042	14	154-5A235 202	5493035007	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.11735	-118.17196	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 AC MODULES ( SUNPOWER-E20 ). SCOPE INCLUDES NEW 125A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61826	13041-20002-35625	4937 N TOPEKA DR	91356	3	168B121    69	2176008003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.16032	-118.54767	change in location of load center and disconnect. no other changes. site plan recheck only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61827	17041-30001-01230	10219-10221 W VENICE BLVD	90034	5	120B165  1326	4314005040	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.02163	-118.40252	Title 24 plan check.  Replace 7 light fixtures.  Total area = 1,430 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61828	18041-20000-10297	700 S MANHATTAN PL	90005	4	132B193   331	5093004068	R4-2	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Closed	12/27/2019 12:00:00 AM	ADDRESS	34.05945	-118.31002	temporary power for construction site.  800 amps.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61829	17041-10001-24031	8601 S LINCOLN BLVD 190	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	33.95939	-118.41943	CHANGES TO APPROVED SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61830	18041-20000-47562	12322 W HESBY ST	91607	2	171B165   966	2356024003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Issued	12/14/2018 12:00:00 AM	ADDRESS	34.16215	-118.40179	Plan check for PV roof mounted system, system size: 12.76kW DC, 11.4kW AC with 44 PV Modules and 1 inverter(11.4kW) Center fed.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61831	15041-20000-33206	10967 W WEYBURN AVE	90024	5	135B149   594	4363017009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.06238	-118.44766	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (RETAIL/KITCHEN). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 969 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61832	13041-20000-20698	3122 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	PIN	34.02680348	-118.42740395	Plan check energy only. Subway.T.I. REMODEL (E) SUBWAY SANDWICH/SALAD 1165 SQ. FT. RESTURANT DECOR CHANGE, CONSTRUCT A DECORATIVE SOFFIT, REPLACE EXISTING FREEZER WITH NEW LARGER FREEZER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61833	18041-10000-23888	5651 W MANCHESTER AVE 1ST Floor	90045	11	096B169   254	4125001901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	33.96006	-118.37965	CHANGE OF USE TO CONVERT EXISTING CAFETERIA AND DINING ROOM TO A LIBRARY ON THE FIRST FLOOR. T-24 ENERGY ONLY. BLDG PERMIT: 17016- 10000-21712	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61834	15041-20000-05468	1603 W WILSHIRE BLVD	90017	1	132A205   392	5142009035	C2-2, C4-2, R4P-2, R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	01/05/2016 12:00:00 AM	ADDRESS	34.05565	-118.27031	Plan check for Title 24 only. Project site is retail. Total lighting area = 2,000 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61835	17041-10000-30262	13575 N GLENOAKS BLVD	91342	7	228B145   438	2501016015	C1-1VL-K-CPIO	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.31859	-118.46426	Energy plan check for removing HID fixture and replace with new LED fixture. Total area is 9500 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61836	11041-10000-20840	551 N PERUGIA WAY	90077	5	138B149    32	4362010007	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	ADDRESS	34.07854	-118.44738	PV solar system , 3 strings.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61837	14041-10000-10072	8500 W BEVERLY BLVD # 852	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT [RETAIL] IN HIGHRISE MALL. 800AMP RATED EQUIPMENT. 29000SQRFT+ TAILORED METHOD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61838	18041-20000-36822	15445 W VENTURA BLVD	91403	5	168B145   769	2261039012	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.15467	-118.47025	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is tenant improvement/combination of (4) existing retail spaces into (1) retail space. Total lighting area = 1,877 sq. ft.Note: Building application has been generated under 16016-20000-25709	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61839	11041-10000-12212	1200 S WALL ST #362	90015	14	124-5A209 213	5145026035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM			PC Approved	06/14/2011 12:00:00 AM	ADDRESS	34.03477	-118.25537	CHANGE OF USE TO RESTAURANT FROM RETAIL; 662 S.F. PLAN CHK IS FOR TITLE 24; PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61840	17041-10003-14793	1313 W SILVIUS AVE	90731	15	006B193    78	7470025026	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	33.71542	-118.30662	PC for changes to approved set. Changes include addition of fuse to AC disconnect for energy storage and relocation of energy storage and AC disconnnect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61841	13041-20000-10694	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	Change to lighting, loads, new transformer in an existing Retail space.  Load is less than 400 amps.  Plan Check Only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61842	19041-10000-07097	10358 N SOPHIA AVE	91344	12	204B137   110	2679024032	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.25904	-118.48734	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIALR ROOF-TOP. TOTAL SYSETM SIZE IS 7.20KWac / 6.40KWdc.(20)AC MODULES-SUNPOWER SPR-X22-360-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61843	18041-10000-20083	624 S GRAND AVE PWR DIST-SYSTEM	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Issued	06/28/2018 12:00:00 AM	ADDRESS	34.04802	-118.25572	PC FOR POWER TO PROVIDE FOR FUTURE LOAD. INSTALLING NEW FEEDER FROM SWITCHGERA ON 4TH FLOOR  800A, NEW FEEDER FROM GENERATOR RISER. ADDITIONAL  ATS TO CONNECT THESE FEEDERS WITH A NEW PANEL.  WORK DONE ON 2ND, 4TH AND 6TH FLOORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61844	17041-10000-00390	350 S GRAND AVE West-Elevators	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	PC for energy only to existing office building, highrise. Work being done on P1 through P6. Adding two lighting fixtures on each level. Area: 170 per floor. Total area: 1020.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61845	19041-10000-00300	1126 E WASHINGTON BLVD 113	90021	9	120A211    21	5131008052	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.02501	-118.25199	FULL PLAN CHECK FOR POWER AND ENERGY.  CHANGE OF USE FROM A RETAIL TO DENTAL OFFICE. TOTAL NEW CONNECTED LOAD IS APPROX 170A WITH TOTAL AFFECTED AREA = 1970 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61846	17041-10000-16365	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	06/26/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR TITLE 24. ENERGY ONLY FOR A  NEW CANOPY COVER OVER EXISTING EXTERIOR PATIO TOTAL AFFECTED AREA OF 551 S.F. SCOPE INCLUDES NEW LIGHTS BL# 17014-10000-02240	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61847	18041-10000-12881	3200 W SUNSET BLVD	90026	13	142-5A203 191	5426007008	C2-1VL	East Los Angeles	Silver Lake - Echo Park	Silver Lake	YES	1958.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.08545	-118.27506	PC FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 1865 SQ.FT SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS.  B# 04016-1000116206	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61848	19041-10000-25258	4515 N EAGLE ROCK BLVD	90041	14	157-5A221  80	5473037007	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	09/30/2020 12:00:00 AM	ADDRESS	34.12659	-118.219	***Grounding and bonding for underground***(((PC FOR POWER AND ENERGY(LOT 1). SCOPE INCLUDES A NEW 1000A SERVICE FOR 12 SFD AND COMMERCIAL SPACES. TOTAL AFFECTED AREA IS 42118 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61849	17041-10001-41833	4226 N IRVINE AVE	91604	2	165B169   746	2368014029	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.14626	-118.38542	EXPIDITE PER APPLICANT REQUEST. PC FOR  ROOFMOUNTED PV ON SFD. SYSTEM SIZE 11.4 KWAC/ 16.0 KWDCSCOPE INCLUDES 39  MODULES  WITH OPTIMIZERS AND CENTRAL INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61850	15041-20000-31352	14732 W OXNARD ST	91411	4	177A149   113	2244009006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.17918	-118.45422	Title 24 plan check only.  Total area = 9,260 sq. ft.  T.I. to existing low rise office space.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61851	19041-20000-26893	114 E WASHINGTON BLVD ste b	90292	11	105A147   213	4225002019	C4-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM			PC Approved	07/15/2019 12:00:00 AM	ADDRESS	33.97991	-118.46498	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.permit fees paid under application number 19041-90000-18754.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61852	18041-20000-34625	21600 W OXNARD ST #1700	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 Energy only in existing office space T.I. Total area: 5008 sq ft. B#18016-10000-24425	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61853	16041-30000-35096	20200 W SHERMAN WAY	91306	3	183B113    62	2135038014	C2-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Apartment			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.20074	-118.57314	Installation of new fire alarm system in new 4 story 20 unit apartment building.  Total system size = 1 FACP + 64 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61854	15041-10000-26359	1660 W ANAHEIM ST FCC-EIV	90744	15	030B201   315	7412022010	OS-1XL, [Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Issued	10/06/2015 12:00:00 AM	PIN	33.77820981	-118.28313647	Power plan check for a (4) circuits (3 from normal and one from UPS panel) to a Hydraulic Power Unit control panel located in a harzadous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61855	12041-10000-22214	117 E WINSTON ST	90013	9	129A213   451	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.04713	-118.24718	TENANT IMPROVEMENT AND CHANGE OF USE OF A PORTION OF THE EXISTING RETAIL TO  A NEW BAR. EPC IS FOR POWER & ENERGY. ((((((( ADAPTIVE REUSE. RENOVATE EXISTING RETAIL & STORAGE SPACES ON BASEMENT AND GROUND FLOOR.  CONVERT SECOND THRU SEVENTH FLOORS TO JOINT LIVE AND WORK QUARTERS FROM EXISTING OFFICE USE. ELECTRICAL PERMIT# 10041-10000-02019, BLDG PERMIT# 09016-10000-11208, 12016-10000-11551))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61856	14041-10000-00035	701 E NEW DOCK ST POWER-SHOP	90731	15	024B209   298	7440021914	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.75567	-118.25325	NEW FIRE ALARM SYSTEM FOR POWER SHOP,  CONSISTING OF 33 DEVICES, 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61857	11041-20000-06852	1902 W PARK AVE	90026	13	139-5A207 209	5404002009	R3-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20, 1975.00	Electrical	Electrical	Apartment			04/06/2011 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.07616	-118.26168	fire alarm senior living	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61858	14041-10000-26626	100 S VOLADOR PL	90732	15	018B193   940	7559017029	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	33.74366	-118.31338	PV1 microinverter, 9.89KW roof-mounted system including (46) Enphase M215 and (46) LG Electronics solar 270W modules  interconnecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61859	14041-10000-14973	7357 N JORDAN AVE	91303	3	186B105   622	2111012023	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.20438	-118.603	T24 ONLY, REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 4620 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61860	14041-20000-19352	3730 E LEE ST	90023	14	120A229   120	5188010009	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.02218	-118.19335	5.2KW PV1 roof-mounted system with (1) Power One PV1-5000-OUTD transformerless inverter, and (16) Sunpower 327W modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61861	12041-20002-11659	19755 W VANOWEN ST A-12	91306		183B117   835	2135022005	(T)(Q)C4-1VL		Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka			Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			PC Info Complete	09/11/2012 12:00:00 AM	ADDRESS	34.19397	-118.56386	Changes to approved set of plans. Additional water heater and washer dryer. Plan check for power only. Original is 12041-20000-11659. Space A-12	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61862	13041-10000-24074	8120 N ROYER AVE	91304	12	189B097   100	2014039010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.21782	-118.62865	PLAN CHECK # WILL BE ASSOCIATED WITH BOTH PLAN CHECKING AND PERMIT # :PV1 ROOF MOUNTED SOLAR INSTALLATION ON STANDARD PLAN. SYSTEM SIZE IS 7.350 KW DC AND 7.5 KW AC. [MODULES: TRINA SOLAR # TSM-245 PC/PA05 |||| INVERTER: FRONIUS # IG PLUS V7.5]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61863	16041-10000-13181	888 S HOPE ST	90017	14	127-5A209  28	5144020196	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Closed	08/25/2016 12:00:00 AM	ADDRESS	34.0452	-118.25996	PC for power only. Temp power for new construction (residential tower). (1) 2000 Amp switchgear 480/277 3p 4w. New load includes man lifts and tower crane.  Project located in a methane buffer zone per zimas Plan checker to verify building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61864	14041-20000-02476	6080 W CENTER DR 3RD FLOOR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	33.97713	-118.39172	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE 3RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61865	14041-10000-21446	9730 N VARIEL AVE	91311	12	201B105   145	2746003006	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.24737	-118.59279	Remove HID light fixtures and replace with new fluorescent. T24. Area = 3840 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61866	18041-20000-42553	10550 N NORTHRIDGE HILL DR	91311	12	207B117   377	2708014005	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.2619	-118.56245	Plan check for a PV1 roof-mounted PV system. System size 21.45 kWdc/19.375 kWac and consists of (3) inverters, (65) modules, (1) back-up battery, and (2) load centers.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61867	13041-20000-33830	15424 W SUNSET BLVD	90272	11	129B125   501	4412001017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.04806	-118.52795	Gelson's Supermarket.  Remodel for entire store. lighting only.  Adding and relocating light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61868	11041-20000-00518	20405 W SORRENTO LANE Bld. 10	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Apartment			01/11/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.27827	-118.57876	New fire alarm system for Building 10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61869	13041-20000-20663	5900 W WILSHIRE BLVD STE 740	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for energy and emergency lighting. 7th floor, Suite 740. Commercial high-rise. Ratkovich Company.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61870	19041-10000-41542	8340 N VAN NUYS BLVD SUITE A	91402	6	192B149   292	2638022061	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.22301	-118.44856	NEW FIRE ALARM SYSTEM WITH 31 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61871	18041-10000-15341	17800 W PARTHENIA ST	91325	12	195B129   440	2787032009	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.22848	-118.52153	PC for new 5kW(ac)/5.4kW(dc) rooftop solar for SFD. Installing 18 modules with optimizer and central inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61872	19041-10001-01178	840 W DOWNEY WAY LJS HALL-2nd Flr	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.01997	-118.28717	"T-24 ONLY FOR TI ON THE SECOND FLOOR OF ""LJS Hall"" BUILDING (USC) in Rooms 253 & 264 RESEARCH LABORATORY REMODEL.  SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND EQUIPMENT. TOTAL AFFECTED AREA IS 1,118 SQ.FTB#19016-10000-00421"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61873	12041-20000-08966	110 S BARRINGTON WALK	90049	11	135B145   481	4429024001	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM			PC Approved	04/19/2012 12:00:00 AM	ADDRESS	34.06536	-118.4692	T.I. to existing space.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61874	10041-10000-00258	555 W 5TH ST	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM	01/07/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	Continuation of the istallation of FA system for high rise building by phases: PHASE I was the installation of the FA panels and annunciator, permit was finaled on 08041-30000-19427; Phases II and III are for the installation of new/replaced  FA devices throughout the floors - plans show that the installation of devices are similar througout the floors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61875	15041-10000-08271	7531 N WHEATLAND AVE	91352	2	186B177   213	2466029017	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.2079	-118.36194	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61876	13041-20000-28787	16501 W VENTURA BLVD SUITE 515	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.1578	-118.49275	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. NON HIHGH RISE. NEW LIGHTING. TOTAL AREA 1020 SQ FT. WORK ODONE IN SUITE 515	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61877	18041-20002-06437	3139 N CHANDELLE ROAD	90046	4	156B177    37	5570023034	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.12757	-118.3647	PC for changes to approved set. Removing all Tesla powerwalls, Tesla gateway and load center. New system is 11.4kW(ac)/13.325kW(dc) rooftop solar for SFD. All fees paid under master permit 18041-20000-06437.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61878	17041-20000-28247	5670 W WILSHIRE BLVD Ste400/460	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,952 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61879	12041-10000-13693	205 S VERMONT AVE	90004	13	135B197    24	5518030022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	10/26/2012 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	34.07015	-118.29188	CHANGE OF USE FROM EXISTING RETAIL TO RESTAURANT (1406  SQ FT): NEW ADA UNI-SEX RESTROOM, NEW NON-BEARING PARTITIONS. (NON-ALCOHOL SALE)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61880	14041-20001-18216	5347 N HINTON AVE	91367	3	171B093   123	2044012005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.16786	-118.63771	Expedite per customer request(((12KW PV1 roof-mounted system with (48) Enphase M215 microinverters and Trina Solar TSM250P modules .)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61881	19041-10001-08518	11839 W SHERMAN WAY	91605	2	183B169    97	2317019902	PF-1XL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.20136	-118.3914	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. RELOCATION OF MAIN SWITCHBOARD, CHANGE OF OVERCURRENT PROTECTION SIZE. <<<<Full plan check for a new 600 Amp service supplying multiple sate approved modulear buildings with a total outdoor lighting area of 9575 SQ.FT>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61882	17041-10000-18174	7902 N WOODLEY AVE A	91406	6	189B141   151	2206007008	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.21417	-118.48347	T-24, PC for energy only. tenant improvment, change of use from storage to office. Scope includes new lights, new receptacles, and one new panel. total affected area is 884 sq. ft. B#17016-30000-05238	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61883	16041-10000-20716	11036 N NESTLE AVE	91326	12	210B125   477	2715016030	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.27075	-118.53051	PV1 SFD TOTAL SYSTEM SIZE 38 MODULES USING MICROINVERTER SYSTEM. ENPHASE M2158.7KW AC. SOLAR SYSTEM IS ROOF TOP MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61884	14041-10000-31419	833 E IMPERIAL HWY	90059	15	087A209   366	6072013022	RD2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Apartment			11/12/2014 12:00:00 AM			Reviewed by Supervisor	12/23/2014 12:00:00 AM	ADDRESS	33.93118	-118.25989	PV 1 System size: 18.5 with 2 inverters (Delta-solivia 7.6TL, (7.6kW)) and 66 modules (LDK SOLAR, LDK-280P-24) ROOF TOP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61885	13041-20000-30554	3535 E WHITTIER BLVD	90023	14	121-5A227 193	5188005020	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Apartment			10/31/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.02634	-118.19728	NEW FIRE ALARM SYSTEM FOR APARTMENT. TOTAL NUMBER OF DEVICES: 242 AND 1 FIRE ALARM PANEL AND 1 ANNUNCIATOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61886	16041-20001-19797	14440 W DICKENS ST	91423	4	166-5A151 231	2266006050	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	34.14956	-118.44755	PV2.  Install 56.94 kW roof mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61887	17041-10000-38399	13200 N CONSTABLE AVE	91344	12	225B133   231	2602001035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.30962	-118.50451	Install New rooftop solar system on a SFD, (48) modules with (48) enphase microinverters	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61888	11041-10000-12677	4395 S GLENCOE AVE	90292	11	105B153    89	4212004003	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	01/21/2012 12:00:00 AM	ADDRESS	33.98557	-118.43796	Replacing Fuel System for an existing Gas station. EPC is for power. (Hazardous Area)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61889	15041-20001-15513	822 N KENTER AVE	90049	11	138B137   240	4494022034	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM			PC Approved	08/08/2018 12:00:00 AM	ADDRESS	34.07362	-118.48947	12/29/2017 Plan check for power only. Project site is a new single-family dwelling. Work includes a new 600-amp service.this is plan check only.  permit fees paid under application 10010-10000-02732/34*****Previous Work Description*****NEW LARGE 2-STORIES SFD WITH BASEMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61890	14041-10000-14316	10711 N ORO VISTA AVE PV1	91040	7	207B189   649	2555009014	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			PC Approved	06/20/2014 12:00:00 AM	ADDRESS	34.2637	-118.31591	PV1.  Permit obtained under 14041-10000-00045.  Plan check only for proposed microinverter PV design.  (((SOLAR SYSTEM INSTALLATION; (19) MODULES 6.0 KW SYSTEM. Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.)))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61891	14041-10000-03257	1920 E VIOLET ST	90021	14	123A217    66	5166018014	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.0324	-118.23331	T24 PART 6 ENERGY ONLY FOR 37221 SQ FT COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. REPLACING TOTAL OF (35) UNITS.  ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61892	16041-20000-40825	18804 W SHERMAN WAY	91335	3	183B121   142	2126002004	[Q]C2-1VL-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.20094	-118.54284	remove existing hid lights and replace with led.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61893	12041-10000-21781	702 E SLAUSON AVE	90001	9	108B205  1504	6007002001	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	PIN	33.98868395	-118.26305615	TENANT INPROVEMENTS IN OFFICES ON THE FIRST FLOOR OF A STORAGE BUILDINGPLAN CHK IS FOR TITLE 24-INTERIOR ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61894	17041-10000-25063	10250 W SANTA MONICA BLVD # 1240	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check- Johnston & Murphy - in retail space# 1240. Electrical service is existing from ""MSA"", attached is approved based build. plan as reference."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61895	14041-20000-08302	4701 N NATICK AVE	91403	4	168A149    31	2265002023	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Apartment			03/27/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.15619	-118.45437	$0 permit fee is due to Senate Bill SB-1222.  PV2.  Roof mounted PV system with size 97.295 KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61896	11041-10000-06860	1542 N CAHUENGA BLVD 1542-1542-1/2	90028	13	148-5A187 356	5546012004	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/06/2011 12:00:00 AM	07/29/2011 12:00:00 AM		Permit Finaled	10/28/2011 12:00:00 AM	ADDRESS	34.0993	-118.32935	T.I.  NEW 600 AMP SERVICE TO SUPPLY A 400 AMP PANEL AND A 200 AMP PANEL.  REGULAR PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61897	10041-20000-14508	425 W 5TH ST	90731	15	015B201    58	7455004800	C2-1-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM	12/01/2010 12:00:00 AM		Permit Finaled	06/27/2011 12:00:00 AM	ADDRESS	33.73951	-118.28626	Plan check power for new 800 KW generator, new switchboard, and equipment. No plan check for low voltage controller.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61898	10041-20000-23365	819 S FLOWER ST Grnd Floor	90017	9	129A207   199	5144021032	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Expired	02/12/2013 12:00:00 AM	ADDRESS	34.04688	-118.26067	T.I. to existing hotel at ground floor.  Install general/emergency lighting in restrooms and corridor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61899	13041-10000-30744	441 S BARRINGTON AVE 1-45	90049	11	132B145   113	4401010057	R3-1, RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Public Safety Only			11/04/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.06009	-118.46885	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING A REMOTE POWER SUPPLY  POWERS ONLY MINI HORNS  CKTS;OTHER CIRCUITS ARE POWERED FROM THE FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61900	14041-20001-03113	2956 S NORMANDIE AVE	90007	8	120B197   322	5054007001	[Q]R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.02756	-118.30006	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61901	08041-10001-19659	811 S FEDORA ST 1-6	90005	10	132B197   539	5094017012	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			02/04/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	07/11/2011 12:00:00 AM	ADDRESS	34.05732	-118.29785	Plan check is for the addition of 11 circuits to house panel HPA only.  The plan was not checked for any carbon monoxide system or fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61902	16041-20000-01481	1155 N HELIOTROPE DR	90029	13	144B197   480	5540025013	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.09239	-118.29513	Plan check for PV roof mounted system. System size: 5.0kW with 16 modules and 1 inverter(5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61903	18041-10001-20299	20000 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Issued	01/08/2019 12:00:00 AM	ADDRESS	34.27519	-118.57042	TI ADDITION TO AN EXISTING FIRE ALARM SYSTEM FORA NEW 3 STORY MEDICAL OFFICE BUILDING. SCOPE INCLUDES 354 DEVICES AND 4 POWER SUPPLIES. DELTA ONE IS PER FIRE CORRECTIONS NOT RELATED TO THE ELECTRICAL SCOPE OF WORK. B#18016-10000-08339	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61904	14041-20001-33302	10805 W STALLION RANCH ROAD	91040	7	204B173   495	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM			PC Approved	05/05/2015 12:00:00 AM	ADDRESS	34.25609	-118.36578	5/5/2015 Changes to an approved set of plans. Main service panel breaker has been derated per inspector request. System size has remained the same.*****Previous Work Description*****PV1 SFD TOTAL SYSTEM SIZE 12KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. THIS IS A GROUND MOUNTED PV SYSTEM. GROUNDMOUNTED BUILDING P# :14020-20000-03169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61905	18041-20001-01292	641 N CRANE BLVD	90065	1	150A223   111	5466006017	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2018 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	34.10672	-118.20996	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (1) load center, and (25) modules. PV system is interconnecting to a center-fed MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61906	13041-10002-35856	540 S COMMONWEALTH AVE	90020	13	135A201   133	5077005027	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.06395	-118.28551	Supplemetal PC power and energy for new lights, removing 16 circuits, 1 light control panel, 2 new circuits, Installing new outdoor lights and 1 PC hour for verifying T-24 compliance. All clouded changes are under delta J. THIS IS PC ONLY. MARTER ALREADY COVERED UNDER MASTER	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
61907	11041-10000-16612	1031 E 34TH ST	90011	9	117A209   345	5114018009	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			08/08/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Closed	03/28/2013 12:00:00 AM	ADDRESS	34.01288	-118.25755	Temporary power for construction equipment.  Temporary power is being supplied from an existing 4.8 KV man hole.    High voltage.  Plan check is for power.  Applican states that the trailers already come equipped with the panels and the circuits.  The circuits within the panels were not charged.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61908	19041-10000-10325	2410 N LILLYVALE AVE	90032	14	139-5A237 104	5220034025	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.07504	-118.16432	FULL PLAN CHECK FOR POWER AND ENERGY FOR TI OF AN EXISTING NON CONDITION STORAGE WAREHOUSE AREA. REMODEL WILL PROVIDE 2700 SF CONDITION STORAGE INCLUDED A FREEZER ROOM, TWO COOLER ROOMS, AND 5 STORAGE CONDITIONED ROOMS. NO CHANGES TO USE. PLAN CHECK INCLUDES CONNECTING TO EXISTING 1600A SERVICE RATED AT 480/277V TOTAL NEW CONNECTED LOAD OF APPROX 800A WITH TOTAL AFFECTED AREA = 2478 FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61909	12041-10000-08498	1734 E 41ST ST	90058	9	114A213    88	5116029006	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM	06/07/2012 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.00788	-118.24202	Tile 24  and emergency lighting, for a walking cooler/ freezer. part of a sigle story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61910	13041-10000-32706	4731 N EAGLE ROCK BLVD	90041	14	159A221    95	5685027016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	34.1312	-118.21665	T24 energy for electrical store office partioned bathtroom. Area 45 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61911	12041-10000-12976	4017 N WESLIN AVE	91423	5	162B157   260	2272025012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.14254	-118.43102	Plan check for new roof mounted 8.7KW photovoltaic system. Single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61912	14041-20001-00767	3304 W BELLEVUE AVE	90026	13	141A201   380	5401013017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/19/2014 12:00:00 AM	ADDRESS	34.07875	-118.2804	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61913	11041-10001-05080	215 W 5TH ST 1st Floor	90013		129A211    77	5149024005	[Q]C4-4D-CDO		Central City	Downtown Los Angeles			Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.04788	-118.25017	"changes to approved set of plans. changes to the retail area. no changes to power, single line diagram, or outdoor lighting per applicant. Plan check for Walgreen for new panels, branch circuits, and lighting.  Plan check for power and energy.  Note: Core and Shell approved plans submitted for reference only.*****Remodel to an existing high rise building with 88 units adaptive reuse.  New services, switchboards, emergency generator, panels, and branch circuits.  Install general/emergency lighting.  File variance for separate fire alarm plans.  EPC is for power and energy.  ""COMPLY WITH DEPARTMENT ORDER effective date 08/04/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  Existing permit issued on application number 09041-10000-15831.  A new plan check was generated due to redesign. *****"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61914	14041-20001-01329	3719 N BEVERLY RIDGE DR	91423	4	162B149   466	2274016009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.13825	-118.44748	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61915	19041-20001-15081	4429 N EDENHURST AVE	90039	13	159B205   285	5594013010	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2019 12:00:00 AM			PC Approved	05/10/2019 12:00:00 AM	ADDRESS	34.13309	-118.27004	05-10-2019 plan check for lost of the permitted set of plan. Plan check only, permit cover under master application.********************Plan check for battery back up system install into existing PV system, Energy battery system size: 13.5kWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61916	17041-20000-41799	6300 W WILSHIRE BLVD 12th Floor	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM			PC Approved	11/17/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for Title 24 only. Project site is the 12th floor of an existing commercial building. Project scope is a partial tenant improvement. Total lighting area = 1,440 sq. ft.Note: Building application has been generated under 17016-10000-29559	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61917	17041-10000-11107	10044 S COMPTON AVE	90002	15	091-5A213 141	6048013042	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.94508	-118.24606	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  900 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61918	19041-10000-19823	3250 S BUTLER AVE	90066	11	120B157   995	4250020009	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.02105	-118.43089	PV1. NEW ROOFTOP SOLAR SYSTEM CONSISTING OF 16 MODULES (CSU6325P), OPTIMIZERS (SE P400) AND CENTRAL INVERTER (SE 3800H-US). SYSTEM SIZE IS 5.2KWdc AND 3.8KWdc	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61919	19041-10000-07140	16613 S FIGUEROA ST	90248	15	066B201   408	6121004027	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	08/17/2021 12:00:00 AM	ADDRESS	33.88033	-118.28277	NEW 3 STORY MIXED USE, RESIDENTIAL/COMMERCIAL BUILDING. (CHURCH DORMATORY)BULDING PERMIT: 15010-10000-02645	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61920	13041-20000-00809	19024 W SPRAGUE ST	91356	3	171B121   283	2163024006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.16607	-118.54735	New  10.5kw PV system for an existing single family residence.  Rootfop mounted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61921	15041-20000-26937	12954 W CORCORAN PL	91340	7	216B161   108	2514010050	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Expired	09/22/2017 12:00:00 AM	ADDRESS	34.28959	-118.41511	Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  Single inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61922	16041-20003-34075	9601 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Approved	09/12/2017 12:00:00 AM	ADDRESS	34.24501	-118.59876	9.12.2017 - Plan check for changes to approved set. Update plan to show soak tank control panels. Update load of soak tanks on panel schedule. Add sump pump circuit. Changes clouded delta D.======Revisions to approved set.  Additional motor assembly loads, deletion of panel.  Delta-D revisions only.  Plan check for power.  Affected sheets: E-003, E-101, E-602. (((TI to an existing single-story commercial building/food production facility.  Addition of new equipment to existing service boards.  Newly connectd load >400 amps - plan check for power and energy.  Total square feet:  17296 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61923	19041-10000-03077	904 S NEW HAMPSHIRE AVE	90006	10	132B197   835	5094026017	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2123.06	Electrical	Electrical	Apartment			01/25/2019 12:00:00 AM			Re-Activate Permit	02/13/2020 12:00:00 AM	ADDRESS	34.05568	-118.29273	NEW 9 STORY  28 UNIT APARTMENT IN A HIGH RISE BUILDING. 8 LEVELS OVER ONE LEVEL OF SUBTERANEAN PARKING. FULL PLAN CHECK FOR POWER & ENERGY. ((Fee Estimate))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61924	14041-20000-07427	515 S FIGUEROA ST SUITE 1000	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 1000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61925	17041-20002-35215	8968 N WHITE OAK AVE	91325	12	195B129    71	2768027001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.23445	-118.51982	02/05/2018Changes to an approved set of plans, changes include the removal of a solar module, roof layout and upgrade to a 5KW inverter. _____Plan check for solar pv system, roof-mounted array on SFD.3kW ungrounded system. (12) 275W pv modules.Each module has a 320W power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61926	16041-30001-20004	749 S BROADWAY 2ND FLR	90014	14	127-5A209  96	5144014028	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.04418	-118.25458	05-11-2017 Changes to an approved set of plan. Changes include additional floor and wall outlet, track light around the perimeter 1 on the second floor and Title 24 forms has been updated. Changes has been clouded as belta	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61927	13041-10000-03751	5000 N DOMAN AVE	91356	3	168B125    27	2181022016	R1-1	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.16066	-118.52793	PV1 MICRO INVERTER two STORY HOUSE. [MIRCRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61928	16041-10001-37059	700 S MANHATTAN PL 1-160	90005	4	132B193   419	5093004003	R4-2	Central	Wilshire	Greater Wilshire		2126.10	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.05945	-118.31002	CHANGES TO THE APPROVED SET OF PLANS. ALL CHANGES UNDER MODIFYING THE LIGHTING PLAN, LOAD CALCULATION , VOLTAGE DROP AND FAULT CURRENT. ALL CHANGES UNDER DELTA-2 ONLY.<<<<<FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 7- STORY(MIX-USE) BUILDING. 160 UNITS WITH 19 TYPICAL UNITS. TOTAL SQ. FT. 145083.SERVICE SIZE = 5000A - 120/208V CLASS.>>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61929	10041-20000-03110	12424 W WILSHIRE BLVD #1400	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM	02/23/2010 12:00:00 AM		Permit Finaled	04/15/2010 12:00:00 AM	ADDRESS	34.04135	-118.47058	office t.i.Energy, emergency Fire Alarm system is by others 10041-10000-02447	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61930	14041-10001-21152	1520 S GLENDON AVE	90024	5	132B153   962	4325027005	R1-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	09/19/2014 12:00:00 AM	ADDRESS	34.05413	-118.43924	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 8.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(32) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61931	19041-10000-13241	4230 S 4TH AVE	90008	10	114B189  1286	5023026008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.00634	-118.32126	pc for pv. system includes 7.8KW (24)Hanwa.Q.Peak-G4. (24) P370 solaredge optimizer. (1) 7600H-US inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61932	14041-10000-22164	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	34.12774	-118.26247	permit to be pulled at EPC counter only. Plan check for energy only per 2013 standards. greater than 100,000SF. TI (E) COSTCO RETAIL. LIGHTING RETROFIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61933	16041-20000-01684	17803 W RAYMER ST	91325	12	195B129   526	2787032013	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.22695	-118.52185	Plan check for PV roof mounted system. System size: 9.8kWac with 44 modules and  2 inverters (6.0kW and 3.8kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61934	17041-10001-20209	14040 W FOOTHILL BLVD	91342	7	225B153   250	2504019049	R3-1-CPIO	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.31435	-118.43968	MODULES WERE REPLACED AS MANUFACTURER FOR ORIGINAL MODULES WENT OUT OF BUSINESS.  PV SYSTEM (189 MODULES 30.025KW AC) WAS ADJUSTED FOR THIS CHANGE OF MODULES.(((((PC FOR PV SYSTEM CONNTECTED TO EXISTING MAIN PANEL. THIS IS COMMERCIAL PV. THIS SYSTEM USES 5 INVERTER, TOTAL RATED34.2KW AC. THIS SYSTEM NET METERS METER # FM19-62711. THIS IS SYSTEM 3/3 ON SAME ROOF. SYSTEM USES POWER OPTIMIZERS. *** NOTE: PERMIT FEES DUE IS $0 DUE TO SENATE BILL 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61935	12041-10000-06024	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	05/30/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	Office TI, new panels and circuits existing service.  Energy is included in this plan check.  Fire alarm under seperate plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61936	18041-20001-45074	11800 N FOOTHILL BLVD	91040	7	210B165   540	2528002901	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District, Pacoima	YES	9800.21	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM			PC Approved	09/12/2019 12:00:00 AM	ADDRESS	34.273	-118.39313	CHANGES TO APPROVED SET DELTA 1 CHANGES IN CONDUIT AND METER SECTION. <<<PV2. NEW ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTERS. (7) SOLAREDGE SE33.3KUS INVERTERS AND (628) PV MODULES. TOTAL SYSTEM SIZE IS 251.2KWdc / 233.1KWac.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61937	16041-10000-43319	5634 W SANTA MONICA BLVD	90038	13	144B193   768	5536018021	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.09063	-118.31261	PC for energy only. Interior tenant improvement in (E) 1 story with mezzanine, change of use from drama school to recording studio and convert the mezzanine to second floor. Total area: 5912	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61938	14041-10000-35545	21909 W VENTURA BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	PIN	34.16940578	-118.60503747	Full plan check for Ralphs.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61939	15041-10001-31884	9025 W BURROUGHS ROAD	90046	4	153B169   382	5564024025	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2015 12:00:00 AM			PC Approved	10/26/2015 12:00:00 AM	ADDRESS	34.11512	-118.39192	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<,pv1, install new 12.099 kw dc roof-mounted solar array on a single family house.(37) modules: SUNPOWER SPR-327-NE-HHT-D(2) inverters: POWER-ONE PVI-5000 & 6000-OUTD-US-A->>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61940	14041-10013-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	"Revision to approved set noted on delta-35: Revise tenant's suite number on Dist. board ""MS ELA-11"" on the single line diagram. Thsi is plan check only, no permit is needed."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61941	11041-10000-25863	9671 N SUNLAND BLVD	91040	2	201B177   261	2542018030	(Q)C1-1VL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	01/18/2012 12:00:00 AM	ADDRESS	34.24723	-118.358	Install new fire alarm control panel with elevator recall and 9 devices for a new 2-story grocery store/Office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61942	17041-10001-07895	2703 S FIGUEROA ST	90007	9	121-5A203  91	5123015001	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Approved	05/01/2017 12:00:00 AM	ADDRESS	34.02698	-118.27698	PC FOR T24 FOR REPLACEMENT OF LIGHTING FIXTURES, PC ONLY - PERMIT ALREADY ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61943	17041-20000-36788	333 S HOPE ST 26TH FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. 6927 SQFT.BUILDING PERMIT # 17016-10000-29728	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61944	14041-20000-02606	7944 N ANDASOL AVE	91325	12	189B133   404	2201022018	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.21542	-118.5116	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61945	10041-20000-21250	10880 W WILSHIRE BLVD #2050	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM			PC Approved	10/25/2010 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check T-24 energy general and emergency lighting for office TI for suite #2050	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61946	19041-10000-02234	221 W E ST 1-10	90744	15	030B205  1039	7418004008	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Apartment			01/18/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	03/22/2022 12:00:00 AM	ADDRESS	33.77562	-118.26428	PC pwr and t-24 for Affordable housing project. two story , 10 unit apartment building for special needs individuals. servise size is 600AMP, 120/240V, 3ph, 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61947	11041-10000-16708	4558 W COUNCIL ST	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2114.10, 2115.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	ADDRESS	34.07451	-118.30962	NEW 600A SERVICE, SUB PANELS, AND CIRCUITS FOR A COMMERCIAL BUILDING WITH MULTIPLE  TENANT SPACES.  ADDRESSES ASSOCIATED WITH THIS PERMIT ARE :  4556 AND 4558 W COUNCIL STREET, AND 143, 147, 149, AND 151 N  WESTERN AVENUE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61948	12041-10000-25995	1560 S ESPERANZA ST	90023	14	117A227    84	5192017001	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM			PC Info Complete	10/30/2012 12:00:00 AM	ADDRESS	34.01413	-118.20085	UPGRADE OVERHEAD SERVICE  TO 600A; NEW FEEDERS TO OLD SWBD WHICH IS TO BE USED AS DISTRIBUTION BOARD FOR EXISTING LOADS; ADD ANOTHER FEEDER TO SUPPLY A PANELBOARD FOR EXISTING LIGHTING CIRCUITS AND FUTURE LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61949	18041-10000-00324	2738 N HYPERION AVE	90027	4	151-5A205 230	5434036029	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.10767	-118.27179	PC for T24 only for retrofit lighting. One for one conversion from flourecent to LED lighting for entire building using retrofit lighting kits. Total area is 12183 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61950	16041-20001-31423	11107 W KLING ST	91602	4	168B173   694	2353031017	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1254.02	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	PIN	34.15585064	-118.37261494	*****VOID*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61951	19041-20000-23947	1125 W ARBOR DELL ROAD	90041	14	165A229    65	5691014014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	11/02/2019 12:00:00 AM	ADDRESS	34.14506	-118.19365	Install 27 kWh energy storage system and associated distribution for whole house load back-up.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61952	10041-20000-25707	9341 N SEPULVEDA BLVD 1-4	91343	7	198B145   189	2656018034	R3-1	North Valley	Mission Hills - Panorama City - North Hills			1172.00	Electrical	Electrical	Apartment			12/28/2010 12:00:00 AM	12/28/2010 12:00:00 AM		Permit Finaled	11/21/2011 12:00:00 AM	ADDRESS	34.24039	-118.468	New fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61953	13041-10000-33047	9154 N HADDON AVE	91352	6	198B165   337	2629014113	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.23576	-118.40172	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3800A-US}]. [(18)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]     'Expedited plan check per applicant request'Bollards to be provided in front of inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61954	19041-20000-46500	17441 W FRASER PL	91344	12	219B129   162	2608010005	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.29903	-118.51411	PV1 PLAN CHECK FOR NEW PV SYSTEM. PV SYSTEM SIZE IS 13 KW DC/10 KW AC. SCOPE OF WORK CONSISTS OF (40) PV MODULES WITH OPTIMIZERS AND A 10 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61955	17041-10001-46221	9320 N MASON AVE	91311	12	198B109    87	2748022056	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Closed	02/11/2021 12:00:00 AM	ADDRESS	34.24018	-118.5796	Changes to approved set of plan to add (1) panelboard, (43) new circuits, (29) new motor loads. All changes are clouded on the plan. Cloud all changes under delta 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61956	12041-20001-13751	5450 S LINCOLN BLVD	90094	11	102B157   293	4211022004	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM			PC Approved	11/16/2012 12:00:00 AM	ADDRESS	33.97348	-118.43093	Modifications to previously approved set of plans.  Install conduit only for future X-Ray machine, change the AIC rating of the circuit breakers that supply the ATS switch at panel A and at the generator to 65000 amperes, and show the feeder to panel C as existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61957	19041-10000-09176	1002 S PACIFIC AVE	90731	15	015B197  1096	7456001001	C2-1XL-CPIO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Issued	03/14/2019 12:00:00 AM	ADDRESS	33.735	-118.28774	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61958	15041-20000-36737	20700 W KINGSBURY ST	91311	12	207B109   432	2706011039	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	ADDRESS	34.26339	-118.58452	Plan check for a PV1 roof-mounted PV system. System size is 8.8 kWac and consists of (2) inverters, (29) modules, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61959	14041-20000-27038	6701 S 11TH AVE	90043	8	102B185  1233	4006025001	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			10/01/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Issued	10/29/2014 12:00:00 AM	ADDRESS	33.978	-118.32959	PC FOR 600A SERVICE UPGRADE. CHANGE IN LOADS. SERVICE UPGRADE ONLY AND ADDITION OF SUBPANELS. RECONNECT EXISTING PANEL TO NEW SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61960	13041-20000-05564	550 S HOPE ST 8th Floor	90071	9	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	34.04989	-118.25574	Change to lighting and loads to an existing office space in a high-rise building.  Load is 432.5 amps.  FULL PLAN CHECK FOR POWER AND ENERGY, REQUESTED BY APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61961	16041-20000-07658	3219 E 6TH ST	90063	14	123A225   115	5186004039	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2041.20	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	PIN	34.03231712	-118.2014162	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61962	18041-30000-29042	15544 W SAN FERNANDO MISSION BLVD	91345	7	210B145   159	2664018030	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	09/23/2020 12:00:00 AM	ADDRESS	34.2717	-118.47115	Full plan check for plan located in a hazardous site. SCOPE INCLUDE  ADDING TWO (2) DOUBLE-SIDED HYDROGEN FUEL DISPENSERS AND HYDROGEN EQUIPMENT TO AN EXISTING GAS STATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61963	16041-20000-37215	150 N BERENDO ST	90004	13	138B197   679	5518027002	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			10/20/2016 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.07425	-118.29398	Plan check for power and energy. Project site is a new 4-story, 21-unit apartment building. Work includes a new 1,200-amp service and associated distribution equipment. Total lighting area is 6,100 sq. ft.Note: Building application has been generated under 16010-10000-04213	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61964	17041-20000-11182	15206 W ROXFORD ST	91342	7	228B145   470	2501020036	C1-1VL-K-CPIO	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.31803	-118.46363	Plan check for power and energy. Project site is a new shopping center complex. Project scope is the core and shell. Work includes a new 800-amp service and a total lighting area of 16,750 sq. ft.Note: Building application has been created under 17010-20000-01382	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61965	12041-10000-20452	4221 W WILSHIRE BLVD	90010	4	132B189    20	5504001014	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01, 2127.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.06194	-118.32113	ON THE 4TH FLOOR , REMODELING EXISTING OFFICES .PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61966	17041-20000-26590	11830 W COURTLEIGH DR	90066	11	111B161   908	4233023016	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			08/03/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	33.9977	-118.41835	Plan check for power and energy. Project site is a new 5-story, 29-unit apartment building. Work includes a 1,200-amp service and a total lighting area of 17,372 sq. ft.Note: Building application has been submitted under 16010-30000-06044	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61967	19041-10000-42626	2449 E CENTURY BLVD	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	03/12/2020 12:00:00 AM		Permit Finaled	08/26/2020 12:00:00 AM	ADDRESS	33.9467	-118.22942	FULL PC (NEW STARBUCKS) FOR A NEW SCOPE OF WORK INCLUDES A NEW 600A SERVICE(120/208 3P, 4W) , AND TWO NEW SUBPANELS. TOTAL AFFECTED AREA IS 4035. B#19010-10K-04643	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61968	18041-10000-23829	2101 E PACIFIC COAST HWY PROJECT 1	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	33.79173	-118.23549	PC FOR NEW FA SYSTEM IN SUBSTATION 12 .SCOPE INCLUDES NEW FACP AND 20 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61969	19041-20000-34645	1122 W WASHINGTON BLVD	90015	1	126A201   241	5135014044	C2-2D-CPIO	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Issued	09/03/2019 12:00:00 AM	ADDRESS	34.03877	-118.28233	Replacement of (E) fire alarm system with new addressable system.  (134) devices and FACP, cellular communicator, and annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61970	16041-20000-38232	1660 W 35TH ST	90018	8	120B193   896	5041007001	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	02/06/2017 12:00:00 AM	ADDRESS	34.02453	-118.30781	PV1.  Install 4.16 kW roof mounted grid-tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61971	18041-20000-03149	5367 N WINNETKA AVE	91364	3	171B113    69	2166006007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	Yes	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.16778	-118.5711	Plan check for the addition of (3) Tesla PowerWalls onto an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61972	19041-20000-41183	16201 W SAN FERNANDO MISSION BLVD	91344	12	210B141  1090	2681011042	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM			PC Info Complete	04/14/2022 12:00:00 AM	ADDRESS	34.27207	-118.48535	PLAN CHECK FOR A 4000A SERVICE, (2) PANEL OVER 1200A, (15) PANELS 601-1200A, (2) PANEL 201-600A, (61) PANELS 0-200A, (123) EQUIPMENT 3.1-5 KVA, (18) EQUIPMENT 5.1-20 KVA, (3) EQUIPMENT 20.1-50 KVA, (659) BRANCH CIRCUITS, AND T24 TOTAL SQUARE FOOTAGE = 99664 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61973	14041-20000-34667	523 W 6TH ST SUITE 310	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	PC FOR T24 ENERGY ONLY. NEW LIGHTING. SMALL OFFICES. WORK DONE IN SUITE 310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61974	18041-10000-07206	1000 W VIN SCULLY AVE	90026	1	138B213   499	5415018016	A1-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	PIN	34.07396264	-118.24410321	PC for power and energy for Dodger stadium club house. Installing new lights and receptacles in team meeting area, storage and restroom. Total area is 1667sqft. Occupancy type is A3. B#18041-10000-04648	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61975	18041-30000-22154	12781 W VAN NUYS BLVD	91331	7	210B161   139	2533019032	[Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.27419	-118.4113	Energy plan check for an outdoor lighting installtion. with a total area of 2,500-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61976	14041-20000-29233	12312 W OLYMPIC BLVD	90064	11	123B149   659	4259025008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM			Not Ready to Issue	02/02/2015 12:00:00 AM	ADDRESS	34.03166	-118.45665	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHTING USING EXISTING POWER EQUIPMENT.  3040 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61977	12041-10000-16152	1630 N NORTH MAIN ST Bldg #13	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.06682	-118.22728	PV2 - Plan check for new roof mounted 33KW Photovlotaic system for LADWP  Building #13. Interconnection to existing overhead power pole.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61978	11041-20000-18742	3300 W TEMPLE ST	90026	13	139-5A201 235	5156003030	C2-1	Central	Westlake	Rampart Village	YES	2086.10	Electrical	Electrical	Apartment			09/02/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	34.07554	-118.28238	Service relocationRevision to 10041-20000-16640	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61979	18041-10001-29964	19700 S VERMONT AVE	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	33.85221	-118.2903	Changes to approved set of plans. All changes are clouded under delta 3. Changes include relocating lighting fixtures on the lighting floor plans. Quantity of lighting fixtures remain the same. Note: Plan check only. Permit is paid under PCIS#18041-10000-29964	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61980	14041-10001-09987	618 S RAMPART BLVD	90057	1	133-5A201  30	5141009023	C2-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			PC Approved	04/13/2015 12:00:00 AM	ADDRESS	34.06174	-118.28164	REVISED LIGHTING PLANS TO SHOW THAT LUMINAIRES ARE CHANGED TO LED TYPES.; NO CHANGES TO THE POWER PLANPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61981	13041-20000-21987	5343 W IMPERIAL HWY BLDG B-PV-2	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	33.93128	-118.37337	PV-2. BLDGB. 500kW AC. Prologis. Bipolar System. Please plan check concurrently with BLDG A on 13041-20000-21985.500kVA isolation transformer will be on separate application.WILL FILE VARIANCE TO SHOW THAT NEW SERVICE IS ONLY FOR PV USE$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61982	16041-20000-14778	10548 N LUBAO AVE	91311	12	207B113   320	2708019036	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			Reviewed by Supervisor	05/13/2016 12:00:00 AM	ADDRESS	34.26101	-118.56729	Install a ground mounted solar array for a SFD. Interconnect with a 200A MSP. System size: 4.8kW. Ungrounded system.(20) EnPhase M250 microinverters.(20) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61983	18041-20001-19742	1101 W PACIFIC COAST HWY	90744	15	036B201   746	7414024033	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM			Reviewed by Supervisor	06/06/2018 12:00:00 AM	ADDRESS	33.79062	-118.27646	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR COMMERCIAL BUILDING FOR 5.5KVA SYSTEM CONSISTING OF 24 MICRO-INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61984	19041-20000-34523	3505 W SUNSET BLVD	90026	13	144A203   188	5429024001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.08911	-118.27635	T24 PLAN CHECK FOR CHANGE OF USE FROM RETAIL TO BEAUTY SALON. LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 1621 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61985	13041-20001-36306	4520 E HUNTINGTON DR NORTH PV2	90032	14	142-5A229 296	5305035006	RD2-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.08413	-118.19022	EXPEDITE FEES ONLY.        <<<<New Photovoltaic system for an existing commercial building.  3-Phase PV system on a 600 amp service.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61986	17041-20000-20218	11136 W MAGNOLIA BLVD	91601	2	171B173   628	2353005013	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.16478	-118.37367	change of use from theater to restaurant.  newly connected load >400 amps.  plan check for power and energy.    Building application number #17016-30000-15466.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61987	16041-10000-02606	11574 W SANTA MONICA BLVD	90025	11	126B149   157	4261013037	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.04473	-118.45335	T-24 ONLY, PC FOR ENERGY ONLY. TI TO AN EXISTING GAS STATION'S CONVENIENCE STORE. SCOPE INCLUDES ADDING NEW LIGHTING TO CONVENIENCE STORE AND RELOCATING 5 PANELS. NO WORK IS BEING DONE TO THE CANOPY OF FUEL PUMP STATIONS. TOTAL AFFECTED AREA IS 1578 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61988	17041-10000-18055	5123 N WILBUR AVE	91356	3	171B121   405	2161004047	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.1637	-118.54556	PLAN CHECK FOR ROOF TOP SOLAR SYSTEM - SYSTEM SIZE  = 15.2KW AC CONSISTING OF TWO INVERTERS (SOLAREDGE-SE7600A-US), AND 48 PANELS (LG320N1C-G4)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61989	17041-10000-40722	6550 W SUNSET BLVD	90028	13	147A187   166	5547026048	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.09782	-118.33303	PC FOR RESTAURANT TI  WITH OCC. LOAD >100 FOR POWER AND ENERGY. (OCC. LOAD 250)TOTAL AFFECTED AREA 4177 SQ.FTSCOPE INCLUDES NEW PANELS, CIRCUITS, LIGHTS AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61990	19041-10001-01637	7601 N CARMENITA LANE	91304	12	186B089    46	2017028041	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.20984	-118.65592	PC FOR PV SYSTEM. SYSTEM CONSISTS OF 21KW (DC) AND 17.6KW(AC). (60) MODULES JINKO JKM365M-72-V. 60 OPTIMIZER SOLAREDGE P400. 2 INVERTER SOLAREDGE 10000H- SECOND IS 7.6 K.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61991	18041-10000-13605	4544 1/2 W MELBOURNE AVE	90027	4	150B197  1173	5590022003	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.10348	-118.28904	NEW ROOFTOP SOLAR SYSTEM ON TWO INTERCONNECTED SINGLE FAMILY DWELLING UINITS ( 1 AND 1/2). (2 OF 2) CONSIST OF  8 MODULES ( EAGLE MP 60B- 285W), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS 320) WITH A CENTRAL INVERTER (SOLAR EDGE SE 3800H-US).  SYSTEM SIZE IS  2.28 KWdc AND 3.8 KWac.(1 OF 2) # 18041-10000-13596	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61992	16041-20000-25890	2651 N HUTTON DR	90210	5	156B157   472	4385007005	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.11975	-118.43017	Plan check for PV roof mounted system. System size: 11.7kW with 36 AC modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
61993	10041-10000-00346	19350 W NORDHOFF WAY	91324	12	195B117    14	2783028041	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Public Safety Only			01/08/2010 12:00:00 AM	01/08/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.23523	-118.55518	New FACP for 24-Hr Fitness facility.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61994	18041-10001-23808	906-908 E 80TH ST	90001	9	099B209   385	6029005026	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	33.9664	-118.25829	EXPEDITE PER APPLICANT REQUEST.(((((((PLAN CHECK FOR ROOF MOUNTED PV(SYSTEM 2 OF 2) SYSTEM - TOTAL SIZE IS 5.0 KVA CONSISTING OF 1 CENTRAL INVERTER (SUNNY BOY-5.0US) WITH 17 MODULES NOTE: PROJECT TO BE ASSIGNED TO ONE PLAN CHECKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61995	18041-20000-15049	24317 W SHREWSBURY CIR	91307	12	183B089    22	2028010010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.20144	-118.65407	Plan check for PV roof mounted system. System size: 13.6kW with 51 modules and 2 inverters(10kW and 3.6kW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61996	17041-20000-41911	11925 W WILSHIRE BLVD 103	90025	11	129B145   934	4265014095	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Issued	12/13/2017 12:00:00 AM	ADDRESS	34.04655	-118.46473	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO MEDICAL OFFICE/ PHYSICAL THERAPY FROM OFFICE.BUILDING PERMIT # 17016-30000-20145	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
61997	19041-20000-29597	8758 N DEMPSEY AVE	91343	12	195B141   554	2672012043	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Issued	07/31/2019 12:00:00 AM	ADDRESS	34.22999	-118.47735	PV1.  Install 12.96 kW DC / 11.01 kW AC roof mounted grid tied PV system.  (36) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
61998	13041-10000-22898	13031 W JEFFERSON BLVD FLOOR 1-FLOOR 2	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	33.97451	-118.42531	TITLE 24 PLAN CHECK ONLY. 2850 SQFT. EMERGENCY LIGHTING. 2 FLOORS. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
61999	10041-10000-06167	5333 W ZOO DR LSS, STILT-HARPY	90027	4	162B197     1	5593002907		Central	Hollywood	Greater Griffith Park	YES	9800.09	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.14867	-118.28623	PLAN CHECK POWER AND ENERGY FOR STILT HOUSE, HARPY EAGLE BUILDING, AND LSS YARD.   BUILDING #0810-10000-02146.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62000	17041-10000-39111	3277 S OVERLAND AVE	90034	5	120B161   265	4254012014	R1-1, R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.02766	-118.41411	New fire alarm panel in a commercial building using 28 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62001	14041-20000-15488	21037 W LULL ST	91304	3	186B105    56	2109020004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Expired	07/21/2016 12:00:00 AM	ADDRESS	34.20952	-118.59194	PV1.  Install 4.335 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62002	13041-10000-15319	380 WORLD WAY T46-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Info Complete	08/14/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	FIRST TIME TENANT FOR TOM BRADLEY INTERNATIONAL AIRPORT. PERMIT HAS ALREADY BEEN PULLED UNDER APPLICATION 13041-300000-09500. TI- BRANCH CIRCUIT & LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62003	17041-20001-14009	22630 W MACFARLANE DR	91364	3	171B097   833	2075022003	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM			PC Approved	05/10/2017 12:00:00 AM	ADDRESS	34.16281	-118.61935	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62004	14041-10000-01683	380 W WORLD WAY #T18-ST-#T62-ST	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	Tenant improvement of airport concessionaire storage spaces #T18-ST and #T62-ST.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62005	10041-20000-01858	9055 N SUNLAND BLVD	91352	14, 6	195B173    75	2408005018		Central, North Valley	Central City	Downtown Los Angeles	YES	1211.02, 2260.02	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM			PC Approved	02/02/2010 12:00:00 AM	ADDRESS	34.23374	-118.36732	"Delta 4 revision to PCIS #09041-20000-17181. Changed fuse type in distribution board, ""DA,"" from J to R."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62006	19041-20000-32598	21331 W COSTANSO ST	91364	3	171B105   167	2167002037	(Q)C1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	11/12/2020 12:00:00 AM	ADDRESS	34.16689	-118.59684	Install 54 kWh energy storage system and associated distribution system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62007	18041-10000-04678	13755 W BAYLISS ROAD	90049	11	138B133    22	4492015016	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Expired	06/02/2024 12:00:00 AM	ADDRESS	34.07848	-118.50687	PC for 6kW PV solar system in SFD with tesla powerwall. Installing 23 modules with central inverter, new load panel and tesla powerwall (under permit 18041-10002-04678). Submitted per applicants request.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62008	14041-20000-11509	849 S BROADWAY Basement	90014	14	127-5A209 313	5144017***	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM			Corrections Issued	05/23/2014 12:00:00 AM	ADDRESS	34.04271	-118.256	New bar and restaurant in the basement of an existing high rise building.  Install panels, transformer, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62009	14041-10001-31814	12950 W ADMIRAL AVE	90066	11	105B157   470	4223006017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM			PC Approved	03/04/2015 12:00:00 AM	ADDRESS	33.98456	-118.4302	CHANGES TO AN APPROVED SET OF PLANS.  EXISTING 200AMP SERVICE PANEL AND ADDITION OF PV PERFORMANCE METER. DELTA ONE REFLECTS THE CHANGES ON THE PLAN SLD. (((PV1 Rooftop residential PV System size: 4.25kW with 1 inverter(Power-one: PVI-4.2-OUTD-S-US-A) and 17 Modules (LG PV Dodule: LG250S1C-G3)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62010	11041-20000-20223	4460 W SANTA MONICA BLVD	90029	13	144A201    39	5539001020	CM-1VL	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.09071	-118.28651	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62011	19041-10000-33717	12105 W WATERFRONT DR	90094	11	105B161  1195	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Issued	09/25/2019 12:00:00 AM	ADDRESS	33.98095	-118.40764	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 180 FA DEVICES, AND 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62012	10041-20001-19557	1940 N HILLHURST AVE	90027	4	150B201   820	5590011009	C4-1D	Central	Hollywood	Greater Griffith Park		1891.01	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM			PC Approved	12/13/2010 12:00:00 AM	ADDRESS	34.1066	-118.28726	Plan check only. Plan check T24 Energy indoor/outdoor for office TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62013	15041-10000-09167	969 E 12TH ST	90021	14	123A211   171	5132014045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.03131	-118.24772	REMODEL OF EXISTING COMMERCIAL BUILDING AND PROVIDE 6 SEPARATE RETAIL SPACES WITH NEW METERING SECTIONS. FULL PLAN CHECK FOR TI 24 AND POWER. ADDING NEW 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62014	15041-10001-06683	8000 W SUNSET BLVD #B140	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM			PC Approved	12/18/2015 12:00:00 AM	ADDRESS	34.09783	-118.36466	12/18/2015CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1. CHANGES INCLUDE CHANGE OF FIXTURE COUNT AND THE RECEPTACLE LAYOUT. (((Plan check for power and energy for a owner build out of a single space (AT&T store) created from one third area of the original core/shell space.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62015	12041-10000-23338	6724 W HOLLYWOOD BLVD	90028	13	148-5A185 146	5547012018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.10139	-118.33715	PLAN CHECK NEW FIRE ALARM SYSTEM FOR EXISTING HIGH RISE BUILDING (CHURCH OF SCIENTOLOGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62016	19041-10000-53449	3846 S GRAND AVE	90037	9	117A203   230	5122027022	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.01381	-118.28	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62017	15041-10000-41921	5926 N MONTEREY ROAD	90042	14	150A231   178	5312010033	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.10524	-118.18409	Installation of a new fire alarm system to a commercial building. (1) FA Panel, (1) Communication panel, (1) Control panel, (39) FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62018	16041-20000-25578	2232 N LIVE OAK DR WEST	90068	4	151-5A193  84	5587005025	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Issued	12/15/2016 12:00:00 AM	ADDRESS	34.11085	-118.31095	"""0$ permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM.  ADDITION TO EXISITNG PV SYSTEM WITH BATTERY BACKUP. SUNVERGE SIS.  EXISTING SYSTEM SIZE: 8.8 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62019	19041-20000-47876	12256 N KRISTOPHER PL	91326	12	219B121   164	2820006022	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.29527	-118.54397	PV1.  Install 14.520 kW DC roof mounted grid tied PV system.  (44) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62020	16041-10000-34921	24244 W GILMORE ST	91307	12	180B089  1045	2033013024	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.18555	-118.65377	SYSTEM IS ROOF MOUNTED PVPC FOR SFD PV SYSTEM. TOTAL SYSTEM SIZE 6KW AC USING 24 MODULES AND CENTRAL INVERTER SYSTEM. USES POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62021	16041-20000-00071	4151 W PROSPECT AVE 5TH FLOOR-BLDG X	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT TO OFFICES.  5TH FLOOR.  BLDG X. 597 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62022	13041-20000-20608	1233 N MCCADDEN PL	90038	4	144B185   208	5532005040	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	34.09379	-118.33758	PC FOR T24 ENERGY ONLY. WORK DONE IN 2 CLASSROOMS. NEW LIGHTING. TOTAL AREA 1659 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62023	12041-20000-17115	10880 W WILSHIRE BLVD 7th floor	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.05885	-118.44283	T-24 lighting plan check for the 7th floor.  The work did not affect the emergency lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62024	13041-20001-26929	19555 W PARTHENIA ST	91324	12	195B117   172	2783025101	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	11/04/2013 12:00:00 AM	ADDRESS	34.22837	-118.55984	RELOCATE SWITCHES AND OUTLETS. RECONNECT MAIN PANEL.(((SUPPLEMENTAL FOR PC FOR T24 ENERGY ONLY. TOTAL AREA 536 SQ FT. )))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62025	11041-10000-06888	6801 W HOLLYWOOD BLVD #B1-150	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			Corrections Issued	04/07/2011 12:00:00 AM	ADDRESS	34.10229	-118.33907	Ti in an existing retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62026	16041-10000-07047	15260 W VENTURA BLVD Suite 2230	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Issued	02/29/2016 12:00:00 AM	ADDRESS	34.15356	-118.4658	TI TO SUITE 2250 - NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62027	17041-20000-07897	3860 S CRENSHAW BLVD #105	90008	10	117B185   821	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM			PC Approved	03/10/2017 12:00:00 AM	ADDRESS	34.01577	-118.33473	Plan check for energy only. TI to existing restaurant (Kim's) and security office. New lighting (incl. emergency). 1,944sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62028	16041-10000-14910	600 E IMPERIAL HWY	90059	15	087A207   290	6072004026	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	33.93089	-118.26467	"CHANGE OF USE SELF SERVICE LAUNDRY MAT TO A RETAIL STORE  ""7-Eleven"".  New MDP and panels with total connected load < 400A. PC for Energy only, total area: 2,600 sq.ftB#16016-10000-08786"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62029	15041-20000-23482	10500 N ANDORA AVE	91311	12	207B101   238	2723016028	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.26089	-118.60882	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (10) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62030	14041-20000-11828	2915 N CHADWICK CIR	90032	14	141A235   257	5217003006	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Expired	05/31/2016 12:00:00 AM	ADDRESS	34.07977	-118.17491	PV1 SINGLE FAMILY. USING MICROINVERTER ENPHASE M215. USING20 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62031	17041-10000-12273	6151 W CENTURY BLVD Unit B	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	33.9457	-118.39308	ENERGY PLAN CHECK FOR THE 1ST FLOOR OFFICE T.I. LOCATED IN A HOTEL SCOPE SPACE IS (1,092 SQ SF).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62032	14041-10001-11040	3303 W BERKELEY AVE	90026	13	144A205   179	5425001001	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.08954	-118.27319	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(13) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62033	17041-20002-15070	2949 1/2 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	34.03799	-118.20329	8.10.2017 - Plan check for modifications to approved set. Equipment on AC side of system must be rated for 22kAIC. Breakers are series rated. SLD updated to show connection to MSP and AIC ratings.=====PV2.  Install roof mounted grid tied PV system sized 1.2 kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62034	19041-30000-25343	590 N VERMONT AVE 2nd Flr-Rm 618	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM			PC Approved	07/02/2019 12:00:00 AM	ADDRESS	34.08157	-118.2915	energy pc only for Tenant improvement of existing office space. area 2415sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62035	19041-20000-16162	6903 N TYRONE AVE	91405	6	183B153   852	2217010022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Issued	05/01/2019 12:00:00 AM	ADDRESS	34.19609	-118.44449	Installation of new fire alarm system in (E) commercial building.  FACP with voice evacuation unit, RPS, cellular communicator, and (51) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62036	19041-20000-24035	18431 W NORDHOFF ST	91325	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM			PC Info Complete	06/21/2019 12:00:00 AM	ADDRESS	34.23565	-118.53505	Change of use from tanning salon to yogurt shop.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62037	17041-10001-37851	1129 N MONUMENT ST	90272	11	129B125   390	4423001039	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM			PC Approved	01/10/2018 12:00:00 AM	ADDRESS	34.0497	-118.52498	EXPEDITE PER APPLICANT REQUEST. ((((((PV1, NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH TWO 5.8KVA/13.5KWH POWERWALL STORAGE BATTERIES. TOTAL SYSTEM SIZE IS12.025KWdc / 10.00KWac.(37)MODULES-SOLARCITY STANDARD #SC325(37)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE10000A-US-ZB-U(2)AC POWERWALL 5.8KVA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62038	14041-10000-15699	6101 W CENTURY BLVD	90045	11	090B169     4	4124030036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	33.9457	-118.39149	PLANCHECK FOR T24 ENERGY. SHERATON- LAX.  TENANT IMPROVEMENT FOR LOBBIES. 32018 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62039	18041-10000-10469	10250 W SANTA MONICA BLVD Delta-39	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"New revision to approved landlord's plan, noted as Delta-39. Revise Breaker size to 600A from DB-ELA43. This breaker will feed tenant ""Anthropology"", ste. #2940. 30 Day demand reading is also submitted for DB ELA43 and DB-44 (Both dist. board are fed from same transformer). This is plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62040	13041-20000-09625	1945 S OVERLAND AVE	90025	5	129B157   764	4321010039	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			04/15/2013 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.04901	-118.43105	Full plan check. Methane zone. Plan check fees per applicant.  PC fees per applicant, please verify during final. Fire alarm variance has not been filed. NEW 8-UNIT, 4-STORY  RESIDENTIAL APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62041	14041-20000-31042	4260 N EAGLE ROCK BLVD 1-56	90041	1	156A219   115	5474022023	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Apartment			11/07/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.12246	-118.22336	PV2Install a roof-mounted solar array on an Apartment building. Interconnect at 600A Main Panel.System size: 14.4kW. Ungrounded system.(60) EnPhase M250 microinverters with (60) 300W pv modules across 4 strings (15+15+15+15).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62042	13041-10000-29619	11151 W MISSOURI AVE	90025	5	126B153   227	4323026016	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.04405	-118.44257	PLAN CHECK FOR TITLE 24 ENERGY ONLY. THE NEW CONNECTED LOAD IS UNDER 400 AMPS. 1 STORY BUILDING WITH ROOF PARKING. NO CHANGE IN OCCUPANCY. OFFICE. 10976 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.note: permit fee calculated under inspection fee period	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62043	15041-20001-33434	16541 W GREENLEAF ST	91436	5	168B137   459	2284005008	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.15604	-118.49369	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62044	17041-10001-12352	3604 N GLENRIDGE DR	91423	4	159B157    63	2272029023	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2017 12:00:00 AM			PC Approved	05/09/2017 12:00:00 AM	ADDRESS	34.13565	-118.4321	PC for new rooftop solar PV. Total system size is 13.9KW and includes 41 SPR-X21-345-C-AC AC modules. one 125A load center .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62045	16041-10000-30560	1400 S FIGUEROA ST	90015	14	126A205   122	5134009022	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	10/12/2023 12:00:00 AM	ADDRESS	34.03868	-118.269	NEW FA SYSTEM FOR 7-STORY APARTMETN BUILDING, WITH 2 UNDERGROUND PARKING. SCOPE INCLUDES 381 FA DEVICES AND 10 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62046	13041-10000-13637	117 E WINSTON ST #101	90013	14	129A213   226	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.04713	-118.24718	Plan check power and energy for time tenant restaurant suite 101. Occupancy over 100.  Title 24 Energy plan under application #13041-10000-13609	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62047	12041-10000-11631	5955 N LINDLEY AVE	91356	3	177B125   762	2157013144	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Public Safety Only			05/21/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.17874	-118.52748	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING IN THE SANCTUARY OF A CHURCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62048	17041-10000-16328	9029 N DE SOTO AVE	91304	3	195B109    20	2779001035	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.23441	-118.58877	PC FOR TITLE 24 ENERGY ONLY.  INTERIOR T.I. WORK FOR (E) RESTAURANT.  TOTAL AFFECTED AREA 591 SQ.FT. SCOPE INCLUDES NEW CIRCUITS AND NEW LIGHTS IN THE KITCHEN.BL 17016-10000-09244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62049	11041-20001-00546	300 W WESTMONT DR	90731	15	027B201   390	7412026016	PF-1XL, [Q]M3-1, [Q]M3-1VL	Harbor	San Pedro, Wilmington - Harbor City	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Info Complete	05/11/2011 12:00:00 AM	ADDRESS	33.76597	-118.28407	Plan check power and energy for revision to approved plans. Changes are clouded on plans. New panel, equipments, additional circuits installed, and 75KVA transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62050	17041-20003-35687	3746 N HAWLEY AVE	90032	13	159B205   752	5594010016	(Q)RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.09066	-118.19042	Revision to approved set of plans.  Increase of system size from (9) to (14) modules and 3.0 kW rated string inverter to 3.8 kW rated string inverter.  Change of load center feeder rating from 100A to 60A.  (((Revision to approved set of plans.  Reduction of system size from (14) to (9) modules and 3.8 kW rated string inverter to 3.0 kW rated string inverter.)))(((PV1Install roof mounted PV system sized 3.8kW with powerwall (battery back-up) interconnected with MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62051	16041-20000-13089	23341 W MULHOLLAND DR Suite A	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.15746	-118.63414	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 462 sq. ft.Note: Building permit has been pulled under 15016-40000-27026	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62052	19041-20000-31263	23341 W LOS ENCINOS WAY	91367	3	171B093   322	2044018010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.16596	-118.6357	PV1.  Install 16.38 kW roof mounted grid tied PV system.  (52) modules with (2) 7.6 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62053	14041-20001-11526	12022 N ELNORA PL	91344	12	216B133   243	2606010028	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/13/2014 12:00:00 AM	ADDRESS	34.28947	-118.50912	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array (4 strings) on SFD. Service size: 7.79kW(2) SMA  America SB3800TL-US-22  transformerless inverters(36) ET Solar ET-P660250BB pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62054	15041-10000-43193	521 W 120TH ST	90044	15	084B201  1090	6088027032	RD2-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	33.92385	-118.28345	PV1 intallation to a residential home. Intalling a 3.0 kw inverter, (15) Kyocera KU2656ZPA modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62055	12041-10000-20579	3848 N LANKERSHIM BLVD	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.13848	-118.36213	remodeling of existing office on the 4th floorplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62056	18041-10000-29065	819 S SANTEE ST #102	90014	14	126A211   457	5145013023	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.04107	-118.25233	PC FOR SMALL RESTAURANT  INTERIOR IMPROVEMENTS FOR T-24 ENERGY ONLY. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES AND EQUIPMENT. RESTROOM IS N.I.CTOTAL AFFECTED AREA 804 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62057	15041-20006-31700	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.25734	-118.50614	9.26.2017 - Plan check for modifications to approved set. Update plans to reflect as built conditions. Revise panel schedules to reflect actual number of spaces available. Change water heater home-run. Adjust SLD - panel C2 feeder is 3ph, ATS is fed by 100A breaker instead of 60A - update feeder, show that inverter/UPS is 15kVA, reduce EGC to #8 for panels A2, B2, and C2. FA is subfed from panel EM-2. EM-2 and EM-3 are subfed from EM-1 with 40A feeds each - update feeder. Delta 6 changes.======8/30/2017changes to an approved set of plans.  changes noted delta 3 only.  changes include updated SLD to reflect field conditions and addition of water heater.  (((Changes to approved set of plans. changes noted (delta 6/12/17).  changes to reflect field conditions.  this is plan check only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62058	12041-20000-30638	20310 W PLUMMER ST	91311	12	198B113    79	2748022075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	34.2426	-118.5759	Change to lighting, receptacles, and load for an existing Warehouse.  Plan check only for Energy with Emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62059	14041-10000-23083	6820 N DE SOTO AVE	91306	3	183B109   822	2137012027	(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	PIN	34.19447423	-118.58747412	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT.  NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD >400 AMPS.BUILDING P# 14016-30000-10638	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62060	11041-10000-27189	1901 S AVENUE OF THE STARS	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM			Reviewed by Supervisor	02/03/2012 12:00:00 AM	ADDRESS	34.05949	-118.41705	PLAN CHECK POWER FOR CENTRAL PLANT. NEW CHILLERS AND BOILERS AT PARKING LEVEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62061	16041-20001-14772	10548 N LUBAO AVE	91311	12	207B113   320	2708019036	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			Reviewed by Supervisor	05/13/2016 12:00:00 AM	ADDRESS	34.26101	-118.56729	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. System size: 2.88kW. Ungrounded system.(12) EnPhase M250 microinverters.(12) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62062	19041-10000-45843	3221 S HILL ST	90007	9	118-5A203  35	5122008005	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	08/01/2020 12:00:00 AM	ADDRESS	34.02054	-118.2745	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62063	19041-20000-52827	3007 S DAHLGREN AVE	90066	11	117B153   109	4248003004	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.02032	-118.44272	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM AND ESS. PV SYSTEM SIZE IS 6.29KW DC/7.6 KW AC. ESS SIZE IS 9.8 KWH. SCOPE OF WORK CONSISTS OF (17) PV MODULES WITH OPTIMIZERS, A 7.6 KW INVERTER, A 5KW TRANSFORMER, A 9.8 KWH BATTERY, AND A 125A PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62064	16041-10005-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	33.94502	-118.40714	CHANGES TO APPROVED SET UNDER DLETA DCN-056.SCOPE INCLUDES WORK IN RESTROOMS, IT ROOM AND CONFRENCE ROOM. NEW LIGHTING AND POWER. SOME REVISIONS TO PANELS SCHEDULE. UPDATED T-24 FORM TO REFLECT NEW LIGHTING. PHOTOMETRIC REVISED FOR THE NEW SPACES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62065	17041-10000-16582	1801 S CENTURY PARK EAST #870	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/17/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.06201	-118.41537	PC FOR OFFICE TI. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62066	14041-20000-00423	6700 W DAY ST	91042	7	204B201   923	2570006021	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.25323	-118.27842	PV1 LF TRANSFORMER. 3 STRINGS FOR 1 INVERTER. TOTAL SYSTEM SIZE 7.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62067	15041-20000-20606	7900 N NELSON ROAD Suite B	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.21499	-118.4422	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,012 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62068	16041-10000-27960	3090 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.01601	-118.21367	PC FOR POWER AND ENERGY. NEW TI IN EXISTING 1 STORY BUILDING, FOOD PROCESSING FACILITY, EXISTING SERVICE, ADDING 800A SWITCHGEAR.  TOTAL AREA 15242. B# 16016-10000-17317.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62069	16041-10000-27225	1375 E 6TH ST	90021	14	126A217    90	5164008021	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM			Reviewed by Supervisor	09/16/2016 12:00:00 AM	ADDRESS	34.03838	-118.23365	PC FOR POWER AND ENERGY. UPGRADING SERVICE FROM 400A TO 800A. ADDITON OF 6 NEW 225A PANELS. AND SCOPE OF LIGTHING AREA IS 6190 SQ FT.DWP FAULT CURRENT REPORT HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62070	14041-10000-27211	1524 E COLON ST	90744	15	036B213   350	7426019017	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/16/2014 12:00:00 AM	ADDRESS	33.79171	-118.24455	INSTALL 2.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62071	19041-10000-32858	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM			PC Info Complete	09/05/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	PLAN CHECK FOR MODIFICATION OF EXISTING BAGGAGE HANDLING AREA - SCOPE INCLUDES ADDITION OF 4 BAGGAGE HANDLING SYSTEMS, MCP'S AND MAINTENANCE RECEPTACLES. BUILDING PERMIT # 19016-10000-22460LAX PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62072	19041-10000-26969	7151 W MANCHESTER AVE	90045	11	096B161   668	4113013028	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	07/15/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	33.95996	-118.41843	T-24 PLAN CHECK FOR NEW SITE LIGHTING FOR RELOCATED ATM AT CHASE BANK BRANCH. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 9783 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62073	10041-10000-17383	3879-3881 S WESTERN AVE	90062	8	117B193  1320	5035024027	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	03/08/2011 12:00:00 AM	ADDRESS	34.01505	-118.30906	REMODEL OF 2-STORIES COMMERCIAL BUILDING- ON THE FIRST FLOOR AND PARTIAL REMODEL ON SECOND FLOORPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62074	16041-10000-18164	1946 E 7TH ST	90021	14	124-5A217 256	5166016001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			Corrections Issued	05/24/2016 12:00:00 AM	ADDRESS	34.03444	-118.2325	PC FOR ENERGY. TI: Interior remodel and exterior alteration, no change of use. ONE STORY BUILDING WITH MEZANINE. TOTAL AREA 2655 SQ FT.B#15016-10000-14057	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62075	18041-20000-16396	14854 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.29436	-118.45487	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter (3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62076	14041-10001-07613	4846 N KATHERINE AVE	91423	4	168B153   242	2248026003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	08/20/2014 12:00:00 AM	ADDRESS	34.15893	-118.44311	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 4.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOME, INTERCONNECT WITH THE MAIN SERVICE.(14) MODULES:  CANADIAN SOLAR CS6X-305P(14) MICROINVERTER: ENPHASE MC4/H4 M250}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62077	19041-20000-02856	1901 S AVENUE OF THE STARS STE 130	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.05949	-118.41705	T24 PLAN CHECK FOR EXISTING OFFICE SPACE IN A HIGH RISE, TOTAL SQUARE FOOTAGE = 655	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62078	14041-10000-31352	8346 N COLBATH AVE	91402	6	192B153   649	2638036021	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.22286	-118.43737	PV1.  Install 7.6 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62079	14041-20000-08572	2045 S PROSSER AVE	90025	11	129B157   595	4321006060	R1-1-O, RE20-1-H	West Los Angeles	West Los Angeles	Westside	YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.05014	-118.42652	PV1 4.5KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(18)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62080	13041-10000-01238	777 S FIGUEROA ST # 700	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM			PC Approved	01/16/2013 12:00:00 AM	ADDRESS	34.04828	-118.26116	RENOVATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62081	18041-20000-32494	2010 E 15TH ST	90021	14	120A215   181	5167019050	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.02236	-118.23536	Plan check for power only in existing wearhouse, replace one for one damaged equipment 1200A 480V and distribution 800A. No new load being added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62082	12041-20000-30854	1501 N SAN PABLO ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM			PC Approved	12/24/2012 12:00:00 AM	ADDRESS	34.06263	-118.20329	Relocate two light fixtures in an existing classroom-laboratory.  Load is less than 400 amps per applicant and occupancy load is less than 99 per applicant.   PLAN CHECK ONLY for Energy-Mandatory Measures, per applicant lighting change is less than 50% and No Allowance is provided.  Inspector to verify existing lighting is not changed.  NO Emergency lighting is a part of this plan check.  ((Full T-24 Plan check may be required subject to field inspection.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62083	16041-10000-39649	3756 W AVENUE 40 2A	90065	1	156A219   325	5472001070	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.1195	-118.22799	PC FOR ENERGY. TI , CHANGE OF USE FROM RETAIL TO A NEW RESTURANT.  TOTAL AREA 700 SQ FT. b# 16016-10000-14010.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62084	18041-10000-37430	5353 W IMPERIAL HWY STE 600	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93112	-118.37375	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62085	18041-10000-13572	1508 N LACHMAN LANE	90272	11	135B121    50	4420035004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	08/15/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.06302	-118.54979	PC FOR TWO ENERGY STORAGE SYSTEMS (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING.  EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62086	17041-10001-35600			2	189B161   421	2305037046	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	PIN	34.21556654	-118.41378194	EXPDITE PER APPLICANT REQUEST. PC FOR ROOFMOUNTED PV ON SLD. SYSTEM SIZE 10.05KW DC 9.28 KW ACSCOPE INCLUDES 29 AC MODULES AND LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62087	13041-20002-21813	8100 N DEERING AVE	91304	3	189B105    77	2109002034	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.21702	-118.59489	(((CHANGES MADE TO APPROVED SET OF PLANS. UPGRADING SERVICE TO 800A. LOADS HAVE NOT BEEN ALTERED)))RENOVATION OF EXISTING WAREHOUSE AND COMPLETE REFURBISH OF BUILDING WIRING. SOME EXISTING LOADS. BUILDING HAS EXISTING 2 SERVICES. RELOCATION OF 1 OF THE SERVICES. PLAN CHECK FOR POWER AND ENERGY. TOTAL AREA 21825 SQ FT. TAILORED METHOD. NONHAZARDOUS LOCATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62088	10041-10000-20364	8323 S VERMONT AVE	90044	8	097-5A199  45	6033023014	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	33.96292	-118.292	TI IN AN EXISTING OFFICE AREA.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS ON THE 1ST FLOOR AND MEZ. LEVEL.  EXISTING PANEL & CIRCUITS.  Electrical plan check did not verify electrical issues for this installation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62089	14041-20000-15218	5237 N NORWICH AVE	91411	4	172-5A147 215	2250019023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.16592	-118.46087	New roof mounted PV system with system size 6.76KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62090	14041-20001-27550	9338 N FARRALONE AVE	91311	12	198B101   217	2727018014	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM			PC Approved	10/11/2014 12:00:00 AM	ADDRESS	34.24012	-118.60987	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7.2kW.(1) ABB PVI-3.0-OUTD-S-US-Z-A transformerless inverter(1) ABB PVI-3.0-OUTD-S-US-Z-A transformerless inverter(40) Kyocera KD255GX-LFB3 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62091	16041-20001-15077	5971 W VENICE BLVD	90034	10	126B173   934	5066003020	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.03865	-118.37272	EXPEDITED PER APPLICANTS REQUEST.Note: This PCIS has 2 PCAM mumbers associated with application. Permit shall be approved on Master Application. PV2.  INSTALLATION OF SOLAR SYSTEM ON CANOPY GARAGE. SYSTEM SIZE: 220 KW DC.BUILDING PERMIT # 16014-20000-01949	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62092	14041-20001-20183	6600 N TOPANGA CANYON BLVD #11	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	[[[10/20/14. CHANGES TO APPROVED. DELTA 1 CHANGES ONLY. CHANGES TO THE FIXTURE SCHEDULE.]]]]]]Plan check for energy only 2013T24 standards. Westfield Topanga - tenant space #11 - Level 1. emergency lighting installed.  BLDG#14016.10.14196	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62093	15041-20001-09694	6316 N TOPANGA CANYON BLVD #1180	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM			PC Approved	11/10/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	11/10/15: Change to an approved set of plan - Lighting control changed, no impact on T-24 forms.Plan check for power and energy for first time tenant New Restaurant. Total area: 2,666 sq ft. Building Permit # 13010-10000-02905	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62094	14041-10000-27076	13710 W OSBORNE ST	91331	6	198B157   691	2625025003	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.23772	-118.43175	Installation of new roof mounted solar PV system.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62095	19041-10000-19301	1603 S FLOWER ST	90015	14	124-5A205  35	5134008007	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.0369	-118.26908	"FULL PLAN CHECK FOR A TENANT IMPROVEMENT (CHANGE OF USE) FROM STORAGE RETAIL BLDG TO AUTOMOTIVE SERVICE CENTER FOR TENANT ""LYFT"". CAR RENTAL,  AUTOBODY REPAIR, BRUSH PAINTING -NO SPRAY BOOTH,CAR STORAGE & OFICE. SCOPE INCLUDES NEW 400A 240/120V SERVICE, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 7548 SQ.FT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62096	16041-20000-44264	5406 N CALVIN AVE	91356	3	174B117   648	2163003052	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Expired	04/13/2024 12:00:00 AM	ADDRESS	34.16904	-118.55617	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (39) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62097	16041-10001-17921	1500 E OLYMPIC BLVD #35	90021	14	123A213   236	5130003059	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.03032	-118.24261	SUPPLEMENTAL PC AND PERMIT FOR T-24,  TENANT IMPROVEMENT AND CHANGE OF USE  FOR A PACKAGED MEAT MARKET RETAIL SPACE from A WHOLESALE USE. NEW ADDITION LOAD < 400A. TOTAL AREA: 1,046 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62098	16041-10000-04261	905 S ARDMORE AVE 1-12	90006	10	132B193   892	5093023027	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.20	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.05563	-118.30221	Installation of a new fire alarm system to a 5 story apartment building. (1) Fire Alarm Panel, (2) Control panels. (1) Communication panel, (64) Fire alarm Devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62099	15041-10000-26641	9912 W COVELLO ST	91504	2	186B181   309	2405019023	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.05	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.2075	-118.34696	ZERO FEES DUE TO 2012 SENATE BILL NO. 1222PV1, INSTALL NEW 12.985 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.  (49) MODULES: KYOCERA KU2606XPA(2) ABB PVI-6000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62100	19041-10001-16893	21029 W OSBORNE ST	91304	3	195B105    42	2779048008	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Reviewed by Supervisor	06/11/2019 12:00:00 AM	ADDRESS	34.23316	-118.59177	VOIDED PER APPLICANT. Expedite per applicant request(((Plan check for a 166kw AC / KW DC PV2 roofmounted system with (2) inverter, (432) modules, (216) optimizer interconnecting through the main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62101	16041-20000-16944	13832 W HAYNES ST	91401	2	180B153   713	2238016011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2016 12:00:00 AM	05/13/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.1893	-118.43447	Plan check for a PV1 roof-mounted PV system. System size is 5.3 kWac and consists of (21) modules, (21) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62102	16041-20000-09029	12862 W FOOTHILL BLVD	91342	7	219B161   309	2514002***	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	34.29316	-118.41524	Plan check for energy only. TI to existing commercial building. New lighting and receptacles. 913sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62103	19041-30000-46343	5700 N CANOGA AVE 3RD FLR.	91367	3	174B105    83	2149019015	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.17365	-118.59715	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 16,873 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62104	18041-30000-11431	19525-19535 W ASTOR PL 19525 HSE	91324	12	198B117   258	2761035101	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			03/29/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.23729	-118.55881	PLAN CHECK FOR POWER ONLY IN 6 NEW TOWN HOMES WITH ATTACHED GARAGE.  600A SERVICEB#18010-30000-00286	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62105	17041-20000-31622	9841 N AIRPORT BLVD Suite 1450	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	Plan check for Title 24 only . Project site is a suite in an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 3,100 sq. ft.Note: Building permit has been issued under 17016-10000-11474. Electrical permit fees have been paid for under 17041-70000-21514.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62106	15041-10000-00987	2968 W 6TH ST	90005	10	135A201   140	5077007001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	PIN	34.06352386	-118.28606577	New methane gas detection system with 39 devices in 7-story mixed use apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62107	15041-10000-04071	10833 W WILSHIRE BLVD	90024	5	132B153   252	4360003023	[Q]R5-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			02/11/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.05971	-118.44117	Title 24 plan check only.  Total area = 3,424 sq. ft. (indoor) + 482 sq. ft. (outdoor)Renovation of existing fitness center.  Installation of new recepticles and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62108	16041-10000-20663	13412 W ORO GRANDE ST	91342	7	228B157   117	2503016049	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.32495	-118.42515	PV1, rooftop solar installation, 5.35 kW DC.    (17) LG320N1C-G40   (15) Enphase M250-60	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62109	18041-10000-33121	1211 S SAN PEDRO ST	90015	14	124-5A211 309	5145026039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.03346	-118.25375	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62110	15041-20000-14489	9 N LATIMER ROAD	90402	11	126B129   646	4409028008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.03989	-118.51393	PV1 SFD. TOTAL SYSTEM SIZE 7.6KW AC USING TRANSFORMERLESS INVERTER. USING POWER OPTIMIZERS. TOTAL OF 36 MODULES INSTALLED. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62111	15041-20000-37491	19101 W JOVAN ST	91335	3	177B121   284	2128024019	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	07/13/2023 12:00:00 AM	ADDRESS	34.18337	-118.54874	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (25) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62112	16041-10000-08703	17383 W SUNSET BLVD A430-BLDG A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.03917	-118.55529	T-24, TI TO AN OFFICE SUITE A430,  SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES.   AREA OF WORK IS 1250 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62113	14041-20000-31739	6469 N GAYNOR AVE	91406	6	180B141   671	2233016018	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.18867	-118.4806	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING SINGLE TRANSFORMERLESS INVERTER. USING 20 MODULES TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62114	13041-10000-30867	12253 W HART ST	91605	2	183B165   255	2321002037	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.19769	-118.40036	PV1, Install 3.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62115	10041-30000-10500	1600 W PALOS VERDES DR NORTH	90732	15	030B193   203	7442001021	RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	33.7793	-118.30549	Lighting and power for patio structure and lighting for basketball court. outdoor and indoor lighting. P/C is energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62116	19041-20001-05383	11633 W KLING ST	91602	2	168B169   671	2354017012	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.1559	-118.38662	Revisions to approved set.  Change of module type and addition of (1) module to system design.  Total system rating increased to 13.845 kW DC.  (39) modules with 11.4 kW rated string inverter.(((Plan check for PV roof mounted system, sytem size: 13.68KW, 11.4KW AC with 38 PV Modules and 1 inverter(11.4KW).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62117	19041-10000-37131	6201 W LA MIRADA AVE	90038	13	144B189   170	5534001022	R3-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Apartment			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	11/24/2021 12:00:00 AM	ADDRESS	34.09359	-118.32468	NEW SPRINKLER MONITERING SYSTEM CONSISTING OF 1 FA PANEL, COMMUNICATOR AND 2 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62118	14041-20001-22167	23355 W CALIFA ST	91367	3	174B093    11	2041006014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			PC Approved	10/03/2014 12:00:00 AM	ADDRESS	34.17683	-118.63612	PV1.  Install 7.020 kW roof-mounted, utility-interactive PV system.  Central inverter with low frequency transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62119	10041-10001-19839	2498 S FIGUEROA ST	90007	9	121-5A203  24	5124027017	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM			PC Approved	10/12/2010 12:00:00 AM	ADDRESS	34.02885	-118.27533	CHANGE PORTION OF EXISTING BUILDING FROM RETAIL TO RESTAURANT PLANS FOR TITLE 24 COMPLIANCE WILL BE SUBMITTED AS SOON AS THE LIGHTING PLAN AND FORMS ARE REVISED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62120	12041-10000-03857	23617 W ELKWOOD ST	91304	3	189B093   527	2020003028	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2012 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	06/13/2012 12:00:00 AM	ADDRESS	34.21258	-118.64138	New 13.68 KW roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62121	12041-10000-08751	4947 N GREENBUSH AVE	91423	4	168B157    27	2359014003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2012 12:00:00 AM			PC Approved	05/17/2012 12:00:00 AM	ADDRESS	34.16084	-118.42591	NEW 5.6KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM WITH SUB PANEL FOR AN EXISTING SINGLE FAMILY RESIDENCE.  NO NEW PANELS OR SUB-PANELS (permit was pulled under# 12041-20000-05752)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62122	13041-20001-03614	948 N BEAUDRY AVE 1-8	90012	1	136-5A213  68	5406026004	R3-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			09/30/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	34.06846	-118.24604	PC FOR T24 ENERGYT ONLY. CHECKING ENERGY FOR PARKING GARAGE. RECHECKING FOR LOST SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62123	19041-10000-19462	725 S FIGUEROA ST # 3005	90017	14	129A207   336	5144009093	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT NON-BEARING PARTITIONS OF (E) OFFICE BUILDING - TOTAL AFFECTED AREA = 2912 SF	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62124	13041-20000-14195	5757 W WILSHIRE BLVD STE 503	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	34.06259	-118.35341	((((T24 FOR 5TH FLOOR OF NEW OFFICE AREA. ELECTRICAL PERMIT HAS BEEN PULLED ALREADY UNDER THE APPLICATION#: 13041-10000-13475))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62125	15041-20000-16827	13543 W CREWE ST	91405	2	183B157   577	2328011070	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.19677	-118.42835	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62126	12041-10000-16885	4400 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.00, 1953.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.09662	-118.28529	Plan check for new installation of new sprinkler monitoring system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62127	15041-20000-18115	7706 W CHANDELLE PL	90046	4	156B177   156	5570023017	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.12637	-118.36407	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (32) modules, and (1) inverter. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62128	14041-20000-27836	8968 N GOTHIC AVE	91343	12	195B137   145	2688002016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.234	-118.48935	PV1.  Install 6.885 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62129	19041-10000-27805	4641 N CARITINA DR	91356	3	168B117   474	2178015005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.15457	-118.55667	(ePlan) INSTALLATION OF (4) NEW TESLA POWERWALLS ON EXISTING 12KVA PV1 SYSTEM CONNECTED TO NEW 200A SERVICE WITH RELOCATED LOADS AND (3) NEW SUBPANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62130	13041-10000-26304	6431 N LONGRIDGE AVE	91401	2	180B157   886	2326025003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	34.18746	-118.4206	PV1 ROOF-MOUNTED 6.25KW PHOTOVOLTAIC SYSTEM  WITH (25) MODULES: TRINA #TSM-250PA05.18(1) POWER-ONE #AURORA PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62131	19041-10000-43267	2902 N GLENEDEN ST	90039	13	150A211   112	5442031017	RD3-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.10645	-118.24888	New PV1 roof top installation using central inverter with a system size of 4.41kW DC / 3.8kW AC (SolarEdged SE3800H-US), 14 modules (hanwha), 14 optimizers (P320), and with a existing service panel size of 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62132	15041-10000-09013	11527 N MAGEE AVE	91331	7	213B161   652	2533020020	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.27939	-118.41665	PV 1. 5.89 KW DC PROOF MOUNT, PV SYSTEM. 18 MODULES  AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62133	19041-20000-03179	23043 W VENTURA BLVD	91364	3	171B097   635	2042012036	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.16438	-118.62819	TI to an existing commercial retail building.  Adding new lighting and new controls to existing panels.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62134	14041-10000-09697	7051 ESTEPA DR	91042	7	198B201    25	2564013006	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM			Verifications in Progress	05/28/2014 12:00:00 AM	PIN	34.24294428	-118.28484742	PV1 7.74KWAC. 240V. microinverter. STD. 1story. groundmount  [(36) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(36)modules: {LG 260 SIC A3}] expired - applicant resubmitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62135	13041-20000-16269	919 S ALBANY ST	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.04913	-118.27045	"NEW PV2 SYSTEM. LAW SCHOOL. ROOF MOUNTED. FOR THIS APPLICATION(3 OF 3) SYSTEM SIZE IS 58KW. PV MODULES LOCATED ON THE ""FOUNDERS HALL"" TOTAL OF 288 MODULES. SINGLE SET OF PLANS HAVE BEEN SUBMITTED. ASSIGN ALL THREE APPLICATIONS TOGETHER. BUILDING CONTAINS OWN SERVICE LINE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62136	14041-20000-32925	2710 N BOWMONT DR	90210	4	153B165    72	4388012050	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.11838	-118.3987	NEW SINGLE FAMILY DWELLING.  2 STORY. 3 PHASE 120/208 800 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62137	19041-20000-17813	555 S FLOWER ST 38th Floor	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check for Title 24 only. Project site is a part of the 38th floor of an exising commercial building. Project scope is a tenant improvement. Total lighting area = 1,040 sq. ft.Note: Building application has been generated under 19016-10000-13788	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62138	19041-20000-30936	350 S GRAND AVE SUITE 3410	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.05173	-118.2522	T24 PLAN CHECK ENERGY ONLY FOR LIGHTS AND OUTLETS OF THE 34TH FLOOR OF AN EXISTING HIGH RISE OFFICE. TOTAL SQUARE FOOTAGE =  3660 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62139	18041-20000-29749	20806 W SPRUCE CIR	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.29498	-118.5872	Plan check for PV roof mounted system size: 3.84kW AC with 12 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62140	19041-10000-20560	7507 N SIMPSON AVE Bld-#D	91605	2	186B169   490	2317010001	R3-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			05/30/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	02/02/2021 12:00:00 AM	ADDRESS	34.20677	-118.3893	Energy plan check for outdoor T.I . Scope includes new panels replacement and new lighting with a total lighting area of 24,505-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62141	16041-10000-07379	17532 W SUPERIOR ST	91325	12	201B129   281	2755009020	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Closed	05/20/2016 12:00:00 AM	ADDRESS	34.2466	-118.51692	PV1, rooftop solar installation 10kW system(44) CS6P-265P(1) SE 10000A-USP300 is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62142	18041-10001-34922	2430 E PORTER ST	90021	14	121-5A217 295	5168029024	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.02651	-118.22916	change to an approved set , change marked delta 4. change includes adding (1) transformer ,(1) panel and  (1) UPS. changing the location of  HVAC equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62143	18041-20000-47782	1457 N VAN NESS AVE 2ND-5TH-FLR	90028	13	147A191   102	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.09731	-118.31598	Plan check for Title 24 only in existing space T.I. Partial 2nd - 5th Floor, circuits existing to remain. Total area: 22,166 sq ft. B#18016-10000-39976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62144	13041-20000-29970	18561 W ELKWOOD ST	91335	3	189B125   576	2103022011	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.21306	-118.53816	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.5 KW AC USING 30 MODULES. USING ENPHASE MICROINVERTER. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62145	14041-20002-34278	19636 W OXNARD ST	91356	3	177B117   673	2153024027	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.17914	-118.56143	[[[[[Plan check to approved set of plan for PV system. Changes apply to delta B only]]]]]low permit fee due to senate bill 1222 from 2012 fee cap.PV1. INSTALL ROOF-MOUNTED SOLAR ARRAY. INTERCONNECTED WITH MAINSERVICE PANEL. SYSTEM SIZE 10 KW. (43) KYOCERA KD255GX-LFB3 MODULES(2) SOLAREDGE  INVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62146	16041-10000-31233	2509 S ROBERTSON BLVD	90034	5	126B169  1228	4302013005	[Q]C4-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	04/24/2017 12:00:00 AM		Issued	04/24/2017 12:00:00 AM	ADDRESS	34.0388	-118.38847	Installation of new roof mounted solar PV array on existing commercial building.  Total system size = 3.5 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62147	16041-10000-02802	16422 W BALLINGER ST	91343	12	201B137  1008	2677012024	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.24373	-118.49005	PV1 roof mounted solar system. Adding a 3KW inverter to an existing 6KW PV system. New Total sytem is 9KW. Adding 13 New solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62148	14041-10000-12149	11626 W TUXFORD ST	91352	6	192B169   338	2632023050	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.22428	-118.38506	Title 24 only - remove HID sixtures and replace with flourescent fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62149	14041-10000-05434	207 N VERMONT AVE	90004	13	138B197   601	5518033020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Expired	03/23/2016 12:00:00 AM	ADDRESS	34.07477	-118.29189	Remove HID light fixtures in existing commercial retail space and replace with fluorescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62150	13041-20000-07320	17555 W VENTURA BLVD 2nd flr-3rd flr	91316	5	171B129   344	2257008049	(Q)C4-1VL, (Q)P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.16199	-118.51602	Change to load for an existing office building.  2nd & 3rd floor only.  Load is greater than 400 amps.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62151	11041-20000-17664	3183 W WILSHIRE BLVD 184A	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20, 2122.03	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.06196	-118.29111	Subway /ENERGY  ONLYCHG USE, GROUND FLOOR RETAIL TO RESTAURANT WITH NON STRUCTURAL T.I, (APPROX 1191 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62152	15041-20000-33408	1418 S VAN NESS AVE	90019	10	129B189  1237	5073002011	[Q]R3-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.04	Electrical	Electrical	Apartment			10/08/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.04567	-118.31555	Plan check for a PV2 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (18) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62153	13041-10000-30840	6255 W SUNSET BLVD SUITE 1525	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR T24 ENERGY ONLY. HIGHRISE OFFICE. 15TH FLOOR SUITE 1525. 791 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62154	12041-10000-18224	6655 N NEDDY AVE	91307	3	180B089   185	2034006009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.19236	-118.65508	NEW 10.56 KW PV SYSTEM ON THE ROOF OF A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62155	13041-10000-24219	437 S BROADWAY	90013	14	129A211    47	5149026008	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.04875	-118.25034	"permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For retail suite A and B with common ceiling. possibly historic monument. See CRA. 18 new lights. existing exit sign to remain. ""COMPLY WITH DEPARTMENT ORDER effective date 06/22/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62156	19041-30000-36493	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029		West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.05956	-118.41375	ENERGY PC FOR COMMERCIAL OFFICE SUITE 900N. AREA OF SCOPE 6,899SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62157	16041-10001-25418	5634 W SANTA MONICA BLVD	90038	13	144B193   768	5536018021	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.09063	-118.31261	08/24/16CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE UNDER DELTA 1. CHANGES INCLUDE REPLACING THE EXISTING HOUSE PANEL WITH A 120/240V 3 PHASE 4 WIRE PANEL. NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-25418 (((((PC FOR POWER AND ENERGY. UPGRADING SERVICE FROM 400A TO 800A  TO AN EXISTING COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS 2818 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62158	10041-30000-04876	7060 W HOLLYWOOD BLVD 5th FL	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	09/15/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	Plan check T-24 Energy for a TI  on 5th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62159	19041-20000-22160	22135 W ROSCOE BLVD LOT #11	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 11.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62160	15041-20001-13178	20321 W AETNA ST	91367	3	177B113   145	2149008010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2015 12:00:00 AM			PC Approved	05/11/2015 12:00:00 AM	ADDRESS	34.17902	-118.57625	Expedite per applicant request*************Plan check for PV roof top mounted system 12.6kWac with 65  modules(Kyocera ku2606xpa) and 3 inverters(PV13.6 outd and PVI 500 OUTD and PVI 3.6 OUTD) connected to 225 main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62161	15041-10000-06455	11111 W SANTA MONICA BLVD SUITE 700	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			03/05/2015 12:00:00 AM			PC Approved	03/05/2015 12:00:00 AM	ADDRESS	34.04771	-118.44481	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 6087.  SCOPE OF WORK IN SUITE 700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62162	13041-10000-35042	735 S FIGUEROA ST SUITES 301-315	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	PLAN CHECK FOR POWER AND ENERGY FOR TENANT IMPROVEMENT TO A RETAIL STORE(ZARA - store #6493). 1st tenant. Emergency supplied from generator. Considered part of hirise. not methane. Core/shell reference#13041-20000-18383.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62163	10041-10000-00425	12730 S FIGUEROA ST #102	90061	15	081B201   254	6132019042	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	06/03/2011 12:00:00 AM	ADDRESS	33.91687	-118.28256	"First time tenant in space #102 ""SABWAY"".  Power and energy.  AC unit are indicated as existing by the applicant.   1st Tenant in this shopping center."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62164	11041-10000-13510	722 S LOS ANGELES ST	90014	14	127-5A211 218	5145002002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM			PC Approved	08/05/2011 12:00:00 AM	ADDRESS	34.04266	-118.25092	TI TO AN EXISTING RETAIL SPACE.  PLAN CHECK IS FOR ENERGY WITH EMERGENCY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62165	17041-10000-14075	5331 N TENDILLA AVE	91364	3	171B105   240	2168025049	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Issued	05/10/2017 12:00:00 AM	ADDRESS	34.16665	-118.6019	Roof mounted PV on SLDSystem size 4 KWACsystem includes 16 modules and microinverters	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62166	17041-10000-38091	18840 W VENTURA BLVD #120	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			10/23/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.17186	-118.54425	FULL PLAN CHECK, T.I. TO EXISTING OFFICE SPACE. REVISING FLOOR PLAN OF THE ENTIRE SPACE. ((B#17016-10000-29666))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62167	16041-20000-12143	5314 N CREBS AVE	91356	3	171B121   209	2161004029	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.16706	-118.54448	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7kW. Ungrounded system. (28) 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62168	14041-20000-25408	18764 W WILLOWTREE LANE	91326	12	207B121   571	2728029063	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.26271	-118.54172	PV1Microinverter Simplified standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6.45kW.(30) EnPhase M215 microinverters(30) SolarWorld SW270 MONO pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62169	14041-20000-16222	5510 S LINCOLN BLVD suite 110	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	33.97299	-118.43051	Plan check for energy only. Remodel on first floor of 5-story building (incl. parking area). New lighting, incl. emergency. Permit under separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62170	18041-10000-13348	2829 W BELLEVUE AVE	90026	13	139-5A203 170	5402006006	C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	01/08/2019 12:00:00 AM	ADDRESS	34.07696	-118.27556	TI IN AN EXISTING BAGEL SHOP.PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62171	16041-20000-27000	6303 N BAKMAN AVE	91606	2	177B173   137	2336015009	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.18508	-118.37808	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.5 KW.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62172	16041-10000-25805	1112 S WILTON PL	90019	10	129B189   549	5081026002	R1-1-HPOZ	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.05046	-118.31436	PV1 roof mounted solar system to a single family home. Installing (31) ACM - SP E20-327-C-AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62173	19041-10000-27086	809 S HILL ST	90014	14	127-5A209  75	5144018053	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Issued	08/05/2019 12:00:00 AM	ADDRESS	34.04431	-118.2562	PC for T24 only, scope of work is a TI in an existing restaurant. Scope includes new lighting, and controls. Total affected area is 2621 sqft. B#: 19016-10000-08036	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62174	16041-20001-31814	3741 N ROYAL WOODS DR	91403	5	162B141   301	2280007020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	34.13893	-118.47247	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar array on a SFD. Interconnect with 200A MSP. New 7.44kW ungrounded microinverter system (enphase 250)  w/(31) 285W pv modules. There is an existing 6.5kW pv system on the roof.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62175	19041-10000-53444	12122 W MAGNOLIA BLVD	91607	2	171B165   587	2356001021	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.16471	-118.39742	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62176	14041-20000-08886	4419 N BABCOCK AVE	91604	2	165B161   230	2362027038	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.15108	-118.40645	PV1Install 7kW roof mounted PV system, interconnect with main service panel.(1) Transformerless inverter - SolarEdge Se6000A with power optimizers.(28) Renesola JC250M-24/BB.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62177	15041-10000-05799	9545 N ARLETA AVE	91331	6	198B157    78	2621023019	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.243	-118.42734	PV1 ROOF MOUNTED SYSTEM. TOTAL SYSTEM SIZE 6KWAC. 18 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62178	18041-10000-18230	8525 N VARIEL AVE	91304	3	192B105   176	2779011036	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.22506	-118.59302	0$ permit fees due to senate bill 1222, ab 1414PV1, roof mounted solar system using central inverters. (88) modules and (3) 7KW inverters. Total system size is 21KWAC and 23.6 KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62179	19041-10000-15139	3037 S PALM GROVE AVE	90016	10	120B181   679	5057029028	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	PIN	34.02608345	-118.34977646	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 12 PANELS (BVM6612M 350W) AND MICRO INVERTERS (IQ7PLUS 290W). SCOPE INCLUDES NEW SUBPANEL 125A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62180	17041-10000-11110	2610 S MENLO AVE	90007	8	123B197   950	5055006012	R4-1L-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Closed	09/22/2020 12:00:00 AM	ADDRESS	34.03234	-118.29018	"Plan check for fire alarm system Emergency voice evacution system for building ""C"" with (11) addressible innitiation devices and (11) supervised auible and visula notification appliances and 1 FACP. Using 12Ah battery."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62181	09041-10002-13995	267 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM			PC Approved	08/04/2010 12:00:00 AM	PIN	33.94684048	-118.40128468	REVISED PLANS FOR TEMPORARY POWER FOR THE CENTRAL UTILITY PLANT AT WWLAX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62182	17041-20000-18440	11824 N STEWARTON DR	91326	12	216B121   372	2872023018	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.2874	-118.54009	0$ permit fees due to senate bill 1222pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62183	16041-20000-25900	5555 W MELROSE AVE 2ND FLOOR	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	01/12/2017 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for Title 24 energy only.  Tenant improvement for 2nd floor executive offices.  7181 sq ftPermit issued to Electrical Maintenance Supervisor Daniel Fischer for Paramount Pictures under license #P035757 (expires 11/01/2017)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62184	15041-20001-20538	23034 W OXNARD ST	91367	3	177B097   508	2041022018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.17906	-118.62875	Expedited per customer request.PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel. (55) Kyocera KU2656 Modules(2) Solaredge SE6000A Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62185	15041-20000-25830	10066 N SAN FERNANDO ROAD	91331	7	204B161   621	2537011004	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.25328	-118.40766	Plan check Title 24 only for Auto Body Shop. Total area: 3,269 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62186	16041-20002-40242	219 S LA FAYETTE PARK PL 1-33	90057	13	136-5A203 125	5155014014	R4-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Apartment			06/05/2017 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.06886	-118.27977	"[[[6/5/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 1 CHANGES ONLY. ADJUSTING FAULT CURRENT AND FEEDER TAGS]]]""0$ permit fees due to senate bill 1222""Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 38.5kW (7.7*5) ungrounded system. (155) 340W pv modules."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62187	16041-20000-45251	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for energy only. TI to North Lobby of high rise building. New lighting (incl. emergency). 6,080 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62188	17041-20000-05764	21855 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.1686	-118.60354	PLANCHECK FOR T24 ENERGY. INTERIOR TENANT REMODEL OF (E) TENANT SPACE FOR (N) RESTURANT. 2564 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62189	10041-20000-12288	8614 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	07/01/2010 12:00:00 AM		Permit Finaled	07/22/2010 12:00:00 AM	ADDRESS	34.07598	-118.37831	OUTDOOR LIGHTING FOR PARKING VALLEY AREA. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62190	15041-20000-43742	5161 N LANKERSHIM BLVD 2ND FLR	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.16452	-118.37469	TI to an (E) office building. PC for Energy only. Total area: 1,789sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62191	16041-20001-19799	12950 W PIERCE ST	91331	7	207B161   165	2536016014	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.04	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.26561	-118.41533	09/01/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes include the addition of receptacles to (3) rooms. *****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR VIDEO EQUIPMENT RENTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62192	17041-10000-30638	2121 S AVENUE OF THE STARS Ste #2480	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	34.05554	-118.41342	PLAN CHECK FOR T24 ONLY FOR TI ON EXISTING SPACE, NO CHANGE OF USE, AREA, OR OCCUPANCY. TOTAL AFFECTED AREA - 5,793 SF. ((B# 17016-10000-24775))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62193	16041-10011-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	05/10/2021 12:00:00 AM	ADDRESS	34.04771	-118.46271	Change to approved set to revise plans to match as-built conditions. Addition of j-boxes, addition of (2) micro inverters for EM lighting, new main disconnect panel for PET CT(MRI)-(part of the equipment) and revised connected load.No new circuits added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62194	19041-20001-21767	3036 N NICHOLS CANYON ROAD	90046	4	156B177   179	5570034015	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	34.12594	-118.36227	Revision to approved plans.  Change of location of equipment and additional disconnecting means. (((PLAN CHECK FOR NEW 27KWH BATTERY SYSTEM OF (2) 13.5 KWH POWERWALL BATTERIES AND A  NEW 200A PANEL. EXISTING PV SYSTEM ON SFD.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62195	15041-20000-15771	2248 N PANORAMA TER	90039	4	148-5A205 358	5432025014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.10023	-118.2696	Plan check for PV roof monted system. System size: 3.6kW with 17 modules and 17 microinverters connected to 200A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62196	13041-10000-35831	5858 N SHOUP AVE SHADE BLDG-#2	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM			PC Info Complete	06/06/2014 12:00:00 AM	ADDRESS	34.17705	-118.6144	PLAN CHECK FOR POWER AND ENERGY FOR NEW SHADE BUILDING.   (3 OF 4 ) ALL FEES FOR ENERGY ARE UNDER APPLICATION # 13041-10000-35818.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62197	13041-10000-30364	13402 S ESTRELLA AVE	90248	15	078B201    76	6132004014	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	33.91039	-118.28596	PLAN CHECK FOR TITLE 24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  19200 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62198	14041-10000-11125	5001 E LINCOLN AVE	90042	1	156A225   343	5477001029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.12065	-118.20688	PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(12)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62199	17041-20001-07893	13718 W VENTURA BLVD	91423	4	165B157   669	2266020005	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.14796	-118.43185	Recheck of lost set of plans.  (((ti to an existing restaurant.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 1540.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62200	12041-10000-11802	14250 W VALLEY VISTA BLVD	91423	5	162B153  1052	2274018004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1412.00, 1417.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	07/30/2012 12:00:00 AM	ADDRESS	34.1447	-118.44409	Plan check new roof mounted 9.6KW roof mounted photovoltaic system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62201	16041-20002-43762	14725 W ARMINTA ST	91402	6	189B149   476	2210021012	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM			PC Approved	02/10/2017 12:00:00 AM	ADDRESS	34.21367	-118.45391	[[[2/10/17 CHANGES TO APPROVED. PLANCHECK ONLY. DELTA A CHANGES. CHANGES ARE CLOUDED. ADDING CONTROLLED RECEPTACLES IN OFFICES AND LOBBY, PROVIDING ACCESS TO MSB ]]]01/11/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan and there has been the addition of outdoor lighting. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for energy only. TI to office building. New lighting (incl. emergency) and receptacles. 9,727sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62202	17041-20000-11168	7930 N MASON AVE	91306	3	189B109   424	2107024029	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Info Complete	06/11/2018 12:00:00 AM	ADDRESS	34.21478	-118.57959	PV2 Install roof mounted PV system sized 30KW AC interconnected with msp.(120) modules(120) solar optimizers(3) 10KW solaredge inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62203	13041-20001-02902	380 W WORLD WAY Space 32	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Full plan check for power per inspector.T24 energy only per supervisorTI OF NEW RETAIL SPACE FOR LAX. THIS IS FOR SPACE # 32. RESTAURANT SPACE. TOTAL SQ FT OF 753.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62204	17041-20001-03545	2010 S CHARITON ST	90034	10	126B173   802	4302034023	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Apartment			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.04017	-118.37798	Revision to approved set of plans.  Reduction of service rating to 400 A, reduction of appliance loads in individual apartment units, and removal of future non-required EV charger.  (((service upgrade 600 amps to an existing apartment building.  plan check for power only, reconnecting existing feeders.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62205	18041-10000-41208	1627 W 20TH ST	90007	1	126B197   953	5075038016	C2-1VL	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Issued	10/29/2018 12:00:00 AM	ADDRESS	34.03826	-118.29237	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62206	19041-20000-53364	3675 N AMESBURY ROAD	90027	4	154-5A203 252	5592013017	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Expired	09/20/2023 12:00:00 AM	ADDRESS	34.11685	-118.27835	Plan check for PV roof mounted system, PV system size: 11.34KW with 36 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62207	19041-20000-17898	10042 W MCBROOM ST	91040	7	207B181    73	2543010041	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Issued	05/15/2019 12:00:00 AM	ADDRESS	34.26393	-118.34991	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM TO EXISTING SFD WITH EXISTING PV. SCOPE OF WORK INCLUDES A LG CHEM RESU 10H BATTERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62208	19041-10000-40056	10208 N OAK PARK AVE	91325	12	204B133   302	2694018012	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.25582	-118.50551	NEW ROOF MOUNTED 5.04KW PV SYSTEM WITH 14 PV PANELS AND OPTIMIZER AND ONE CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62209	15041-20001-37727	18209 W PARTHENIA ST	91325	12	195B125   794	2769019041	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM			PC Approved	12/07/2015 12:00:00 AM	ADDRESS	34.2289	-118.52978	EXPEDITE PER APPLICANT REQUEST. (((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERICAL ROOF-TOP. TOTAL SYSTEM SIZE IS 79.12KWdc/80.0KWac. (344) MODULES-SCHUCO MPE-230W (4) INVERTERS-GROWATT 20,000-UE (240V)(1) 200A SUBPANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62210	14041-10000-32465	2854 N PARTRIDGE AVE	90039	13	150B213   904	5442026006	R2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.10422	-118.24719	Plan check for a roof-mounted PV system. System size is 6kW. System consists of (27) modules and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62211	18041-10000-10419	10250 W SANTA MONICA BLVD #1700	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space two story restaurant ""Del frisco Double Eagle Steak House""  suite 1700, install:   (1) 800A, 120/208V, 3ph, 4W; (1) 300kVA transformer;    (5) Panelboards < 400A(1) Inverter;  Lightings and Power;   Total area: 15,474 sq.ft (indoor) + 500sq.ft (outdoor dining)(B# 18016-10000-08601)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62212	11041-10000-21049			15	060B193   387	7351001024	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM			PC Approved	10/21/2011 12:00:00 AM	PIN	33.85879353	-118.30801268	new offices/restrooms /storage inside a  warehouse buildingplan chk is for title 24 with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62213	09041-10001-24226	13488 W MAXELLA AVE	90292	11	105B153    77	4212004014	[Q]M1-1, [T][Q]RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	Changes made to previously approved set, out door lighting with metal halide. 4 new ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62214	17041-10000-30579	4126 N VERDUGO ROAD	90065	14	157-5A217 209	5459026006	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			Corrections Issued	08/25/2017 12:00:00 AM	ADDRESS	34.12583	-118.23171	CHANGE BEER TAVERN TO BAKERY. new lighting. pc for t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62215	13041-10001-29595	1575 N QUEENS ROAD	90069	4	147B173    40	5559025002	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.09896	-118.37732	Expedited RSES plan check per applicant request.((((PV1.  Install 12.5 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: Fronius IG Plus V 11.4.  50 modules: HANWHA # HSL60P6-PB-4-250TW.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62216	13041-10000-10088	7438 W 80TH ST	90045	11	099B157   289	4114014020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	06/01/2013 12:00:00 AM	ADDRESS	33.96365	-118.4276	PV1 SINGLE FAMILY DWELLING; 2-STORY HOUSE). 8.04 ROOF MOUNT SOLAR SYSTEM. 24 MODULES, 1 INVERTER. [INVERTER: SUNPOWER X21-335-BLK] [SOLAR MODULE: SUNNY BOY 8000-US].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62217	12041-10000-17480	255 S GRAND AVE	90012	14	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Apartment			07/26/2012 12:00:00 AM	06/25/2013 12:00:00 AM		Issued	06/25/2013 12:00:00 AM	ADDRESS	34.05332	-118.25122	PLAN CHECK REPLACING EXISTING FIRE ALARM SYSTEM WITH NEW SYSTEM FOR HIGH RISE BUILDING. EXISTING BUILDING CI CABLE TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62218	17041-10000-20343	1891 W EFFIE ST	90026	13	142-5A209  70	5420001017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.08449	-118.25659	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62219	17041-20000-13517	11779 W SHELDON ST	91352	6	198B169    30	2537023001	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Issued	05/01/2017 12:00:00 AM	ADDRESS	34.24235	-118.38988	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 800 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62220	13041-20000-21033	14600 W SHERMAN WAY STE 100D	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	34.20095	-118.45113	Plan check for energy and emergency lighting. Offices in a low-rise commercial. Suite 100D. PC APPROVED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62221	12041-10001-15380	4401 S CRENSHAW BLVD Basement	90043	8	111B185   131	5013013013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	PIN	34.00326739	-118.33207301	Plan check plan check for additional changes to original submittal. T.I. of existing  office space on basement level for MTA Sheriff's Station. Facility not a Critical Operations Power Systems (COPS) per Los Angeles County Sheriff Dept. Permit under #12041-10000-15380.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62222	16041-10000-22299	5999 W CENTER DR STUDIO	90045	11	102B169   959	4104023018	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Issued	10/21/2016 12:00:00 AM	ADDRESS	33.9761	-118.38876	PC FOR T24 ENERGY ONLY. NEW LIGHITNG IN STUDIO ON FIRST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62223	14041-20000-17736	124 S CROFT AVE	90048	5	138B173   687	5511014007	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	01/17/2023 12:00:00 AM	ADDRESS	34.07387	-118.37406	New 13-unit 5-story apartment building with one level subterranean parking.  Power and energy.  Methane zone.Variance to separate fire alarm plans filed 06/30/2014.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62224	12041-10001-00397	5541 N LAUREL CANYON BLVD	91607	2	174B165   809	2347015024	R3-1, [Q]C1.5-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	34.17135	-118.3967	Plan check for revision to approved plans. Changes to solar module type, relocate inverters location, and solar equipment. 39.840 KW (DC)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62225	12041-10000-12350	820 E 3RD ST	90013	14	129A215   309	5163015017	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	ADDRESS	34.04572	-118.23556	Outdoor lighting to an existing commercial building.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62226	10041-20000-24843	727 W 7TH ST 1-222	90017										Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM			Corrections Issued	12/14/2010 12:00:00 AM	ADDRESS	34.04861	-118.25837	T.I. to a high rise building of a Salvage Bar.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62227	18041-20000-34604	5632 W LA MIRADA AVE	90038	13	144B193   292	5536004033	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.09365	-118.31214	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62228	19041-10000-12619	750 S LAMAR ST	90031	14	133-5A219   5	5410002818	[Q]M3-1-RIO	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	34.06186	-118.22511	PC for new FA for Railroad. 1 New panel & 152 Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62229	15041-20001-25940	5112 N MAMMOTH AVE	91423	4	171B157   775	2269001026	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.1634	-118.43229	09/11/2015 Changes to an approved set of plans. Changes includes the replacement of the 5 kWac inverter with a 6 kWac inverter. Everything else has remained the same. Permit will remain valid on master application.*****Previous Work Description*****Installation of new roof mounted solar PV array.  Total system size = 5.45 kWac.  Central inverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62230	18041-20000-26806	4245 N LANKERSHIM BLVD	91602	2	165B177   832	2423022046	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.14719	-118.3642	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62231	14041-10000-05997	5456 S MCCONNELL AVE	90066	11	102B161    26	4211009031	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	33.97743	-118.41904	INSTALLATION OF A NEW FIREALARM SYSTEM  FOR ANIMO WESTSIDE MIDDLE SCHOOL. FULLY SPRINKLERED. 2 PANELS AND 125 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62232	10041-10002-06654	1845 S PONTIUS AVE	90025	5	126B153   198	4323026015	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.04443	-118.44248	CHANGE FEEDER TO PANEL B FROM 150 AMPERE 1/0 TO 200 AMPERE 3/0.  Same voltage charecteristics, no change in loading.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62233	11041-10000-03471	655 S HOPE ST Basement	90017	9	129A209   262	5144006901	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	07/20/2011 12:00:00 AM	ADDRESS	34.04849	-118.25759	Ti for a juice bar in a highrise building. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62234	09041-10005-13995	267 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM			PC Info Complete	01/20/2011 12:00:00 AM	PIN	33.94684048	-118.40128468	Change the priviously approved plan. Change the size of equipment ground and over current devices.  EPC is for power. (approved plan was attached for reference.) ((((((((((((((((((1200 AMPS BRKR CHANGED TO 1100 ON FEEDER # 3 , AND GROUN COUDUCTORS UP SIZED ON FEEDERS 3 003, 008,009,010,011,016,017,018 AND 012.))))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62235	17041-10001-33868	3214 W 75TH ST	90043		102B185  1182	4012013010							Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM			PC Approved	11/03/2017 12:00:00 AM	ADDRESS	33.97169	-118.32924	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62236	12041-10000-30961	8054 W 3RD ST	90048	5	138B177   752	5511028012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/26/2012 12:00:00 AM			Reviewed by Supervisor	01/07/2013 12:00:00 AM	ADDRESS	34.07194	-118.36557	new building from previuos renovation. installing new 1200A service along with new pannel boards and branch circuits for first time tenant. permit already exist, this is plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62237	15041-20000-04938	10204 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.25583	-118.57964	PLANCHECK FOR POWER AND ENERGY. VETERINARIAN CLINIC 3594 SQ FT TENANT IMPROVEMENT WITHIN EXISTING SHOPPING CENTER. NEW VETERINARIAN CLNIIC INCLUDES LOBBY, RESTROOMS, EXAM ROOMS, TREATEMENT AREA, XRAY SURGERY AND SUPPORT AREAS. NO OVERNIGHT STAYS PERMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62238	16041-20001-41279	5005 N RUBIO AVE	91436	5	171B137   431	2259013003	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/19/2016 12:00:00 AM	ADDRESS	34.16142	-118.49468	Revisions to approved plans.  Change of interconnection details.  Solar only load center changed to a house subpanel with relocated loads.  (((PV1.  Install 4.28 kW roof mounted grid-tied PV system.  Microinverter standard plan.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62239	14041-20000-27128	22551 W UHEA ROAD	91364	3	168B097   824	2076015063	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.15225	-118.61861	PV1Install roof-mounted solar array on SFD. System size: 3.87kW.(18) EnPhase M215-IG microinverters(18) SolarWorld Poly SW250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62240	17041-20000-41606	400 S HOPE ST 13th flr	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.05199	-118.25366	ti to an existing commercial building (highrise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62241	11041-20000-03621	127 S SAN VICENTE BLVD TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM			PC Approved	02/25/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision to approved plans changes to reflect the changes done to OSHPD portion of the building TI onlyDelta 40	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62242	17041-10000-25043	440 N ALVARADO ST	90026	13	138A207   262	5157023023	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.07132	-118.26715	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AREA IS 7125 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62243	14041-20000-08821	6420 W WILSHIRE BLVD #230	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I. to a high rise building on 2nd floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under 14041-20000-06707	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62244	15041-10000-25960	15119 W SUNSET BLVD	90272	11	129B129   947	4423017004	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.04561	-118.52343	Energy plan check for a commercial ( nail shop) )T.I. Scope includes new receptacles and lighting; Total area is 1200-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62245	12041-10003-15263	400 W WORLD WAY 4b	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	Addition of lighting in food truck section prefab truck. title 24.  hanges to approved set of plans: 2panels were changed to have feedthru subpanels. one luminaire changed from 1 socket to 3. added Device power for Food truck equipment. service load calcs changed. relocated some panels. moved switches. tied EF and MUA. added bugeye instead of battery backup for light. Located in Terminal 4, departure level, space 4B, foodcourt.New electrical panels and circuits for 5 new restaurants.  Full plan check for Power and Energy. TI previously restaurants converted to new food court including (N) partitions, millwork and ceiling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62246	09041-20001-13520	13730 W ROSCOE BLVD North 2	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM			PC Approved	12/22/2010 12:00:00 AM	ADDRESS	34.22149	-118.43179	Plan check only. Revision to approved plans to show changes to single line and equipment layout. Remove circuits from panel A and no new loads added to approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62247	18041-10000-41743	1452 S BEDFORD ST 1-6	90035	5	129B169   281	4303018028	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.05252	-118.38062	FA COUNTER CHECK FOR RESIDENTIAL 6 UNIT APARTMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62248	17041-10001-04219	8631 W 3RD ST 245	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check for Title 24 only in existing space, office T.I. Total area: 355.4 sq ft.Note: Permit was pulled under Application #: 17041-90000-04219	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62249	10041-10000-17594	1253 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.05086	-118.22593	Solar voltaic system installed on the roof of the building.  Consists of 10 modules,  10 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62250	19041-20001-03820	14920 W JADESTONE DR	91403	4	162B149   576	2278011009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.1369	-118.45874	Expedite per applicant requst. Plan check for PV system and battery back up system, PV system size: 9.765KW with 31 PV Modules. Battery back up system size: 27KWh with 2 Tesla Powerwall 2.0.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62251	19041-10000-25364	22707 W COLLINS ST	91367	3	174B097   310	2040006022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.17406	-118.62153	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 20 HANWHA QCELL MODULES 285W, 20 OPTIMIZERS (SE P320) WITH SE 5KW HD WAVE INVERTER. SYSTEM SIZE IS 5.7KWdc AND 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62252	18041-10000-31304	16355 W CELINDA PL	91436	5	165B137   255	2284017017	RE15-1-H	South Valley	Encino - Tarzana	Encino	Yes	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.14883	-118.48875	*Zero permit fee per Senate Bill 1222/ AB 1414*Install new PV1 rooftop solar system on an (E) SFD. System size is 16.17 kW DC/ 15.43 kW AC, (49) modules, with (49) microinverter.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62253	16041-20000-09984	20318 W STRATHERN ST	91306	3	189B113   510	2107025058	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.21546	-118.57613	Plan check for the addition of a 9.2 kWac PV system onto an existing 3 kWac PV system for a total system size of 12.2 kWac. System addition consists of (2) inverters, (44) modules, (1) combiner box, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62254	17041-20001-32612	15012 W MOORPARK ST	91403	4	168B145   965	2264016077	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.15358	-118.46005	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. ADDITION OF (2) 60A PANELS AND THREE BRANCH CIRCUITS. CHANGES TO FEEDER SCHEDULE, SINGLE LINE, FAULT CURRENT CALCS, VOLTAGE DROP CALCS, AND ELECTRICAL SITE PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62255	14041-20000-00981	10568 W FOOTHILL BLVD	91342	7	210B177   171	2529013017	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Issued	01/16/2014 12:00:00 AM	ADDRESS	34.27419	-118.36103	pv1 single family dwelling. total system size 3.6 kw ac using transformerless inverter nonstandard plan 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62256	13041-10001-24104	2920-2930 W ROWENA AVE BLDG 3	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.10823	-118.26884	CHANGES MADE TO PREVIOUSLY APPROVED SET: A) ADDITION OF PV TO EACH RESIDENTIAL UNITB) REMOVE LIGHT FROM GARAGEC) ADDITONAL J BOXES IN RESIDENTIAL UNIT FOR FANS, LIGHTS, ETC.D) REMOVE LIGHT (FL) AND REPLACE WITH INCANDESCENT WITH DIMMER IN HALLWAYSE) ADDITION OF OUTDOOR LIGHT FOR COMMON AREA LIGHTING(((CONSTRUCTION OF NEW TOWN HOUSES, PLAN CHECK FOR POWER BUILDING 3 OF 6.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62257	14041-20000-24093	31 E 26TH AVE	90291	11	105A145   206	4226018013	RD1.5-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	33.98221	-118.46831	PV1.  Install 4.32 kW AC roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62258	17041-10001-17601	3611 S GRAND VIEW BLVD	90066	11	114B153   703	4248026040	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.00865	-118.43436	Expedite fees only.       Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10.25 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62259	15041-20001-39875	6800 N OWENSMOUTH AVE #160	91303	3	183B105   949	2138006044	P-1VL-RIO, [Q]CR-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.19413	-118.60138	Change to approved set of plans. Changes include delta1 only. {{{{{TI O OFFICES. NEW LIGHITNG. PC FOR T24 ENERGY ONLY.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62260	15041-20000-27194	2918 S LA SALLE AVE	90018	8	120B193   148	5053022004	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.02849	-118.3052	PV1. Install roof mounted PV system sized 4 kW. Interconnected with main service panel.(8) Sunpower E20-327 Modules(1) PVI 3.0 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62261	15041-20000-12741	19801 W VANOWEN ST	91306	3	183B117   835	2135022040		South Valley				1348.00	Electrical	Electrical	Commercial			04/28/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.19396	-118.56457	Plan check fot T-24 Out door lighting only. Remove existing and install new can light. Total out door area: 2,552 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62262	19041-20000-36340	5640 N WILHELMINA AVE	91367	3	174B089   413	2046015012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.17243	-118.64935	PLAN CHECK FOR ADDITION TO EXISTING ROOF PV SYSTEM. ADDING 4.65KW DC AND 3.8KW AC TO EXISTING SYSTEM SIZE. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH OPTIMIZERS AND A 3.8KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62263	13041-10000-31038	1410 S MAIN ST	90015	14	124-5A207 256	5133012003	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.03491	-118.26127	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  1073 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62264	11041-10000-25751	8484 N SAN FERNANDO ROAD Front Bldg	91352	6	192B173   223	2632027023	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	12/02/2011 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.22408	-118.37533	INSTALL ADDITIONAL DEVICES ON AN EXISTING FIRE ALARM SYSTEM IN THE FRONT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62265	15041-10000-15270	5837 W SUNSET BLVD	90028	13	147A191    55	5545011053	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			05/19/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.09822	-118.3171	Installation of new fire alarm system for 5-story with parking in the first floor. 284 fa devices and 6 control panels and one fa panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62266	14041-20000-13912	10700 W SANTA MONICA BLVD 2ND FLR	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.05167	-118.432	pc for t24 energy only. new lighitng in office space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62267	14041-20000-09759	4647 N CANOGA AVE	91364	3	168B105   932	2190016004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Expired	06/01/2016 12:00:00 AM	ADDRESS	34.15278	-118.59611	PV1.  Install 5 kW DC roof-mounted PV system, interconnect with main service panel.  (20) modules.  Microinverter nonstandard plan: Enphase M215-60-2LL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62268	18041-10000-33660	2933 N DIVISION ST	90065	1	150B213   995	5456014063	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.10337	-118.23544	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR TAKE-OUT RESTAURANT. TOTAL AFFECTED AREA IS 1223 SQ. FT. B#18016-10000-28406no screw base is allowed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62269	09041-10003-24398	5500 W SUNSET BLVD	90028	13	147A193   108	5544029011	C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.09793	-118.30958	"DELTA ""152,154,155"" CHANGES TO APPROVED PLANS. NEW SERVICE 1200A, PANELS, LOADS, ENERGY 163,000 SQR FT. -ONLY CLOUDED CHANGES ARE APPROVED UNDER THIS PERMIT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62270	19041-10000-19541	450 S WESTERN AVE #206	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.06562	-118.30887	POWER AND ENERGY PLANCHECK FOR  A SKIN CARE CLINIC T.I. SCOPE INCLUDE NEW 30KVA TRANSFORMER, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1255 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62271	17041-10000-11984	15101 W SAN FERNANDO MISSION BLVD	91345	7	210B145    79	2664001022	A2-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.27287	-118.45995	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 35225 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62272	19041-10000-13064	1730 N WESTERN AVE	90027	13	148-5A193  68	5544007026	C4-1D, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.10267	-118.3091	Full plan check for a 2-story 60-guest room motel remodel with new service, equipment and lighting. Total area is 11,000-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62273	10041-10000-18516	2049 S CENTURY PARK EAST 13	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI office and storage total about 360 square ft.  This plan check is only for T-24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62274	19041-10000-33998	1771 W BLAKE AVE BLDG 3	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/30/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	3 OF 11. BLDG 3POWER PLAN CHECK FOR 1200A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDINGS AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62275	10041-20000-19680	11100 W SANTA MONICA BLVD 16th Floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM	10/18/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.04726	-118.44465	Plan check T-24 Energy for space TI on the 16th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62276	19041-10000-13110	5147 E ALHAMBRA AVE	90032	14	138A235   161	5216021051	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2016.01	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.07261	-118.17381	NEW SERVICE AND SWGR TO REPLACE FIRE DAMAGED EQUIPMENT. ALL LOADS REMAINED THE SAME.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62277	19041-20000-01479	3449 S MCLAUGHLIN AVE	90066	11	117B157   624	4249022004	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.01524	-118.42991	installation of (2) tesla battery back up 5KW each.  to an existing pv system.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62278	19041-10000-38646	1316 S MALCOLM AVE	90024	5	132B153   569	4325011019	R1-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.05743	-118.43895	NEW 12.86KW ROOF MOUNTED PV SYSTEM WITH 42 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62279	13041-10001-30910	4816 S 6TH AVE	90043	8	111B189  1012	5014018004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	33.99949	-118.32345	Expedited RSES plan check per applicant request. (((V1, Install 1.96 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: AURORA PV1-3.0-OUTD-S-US. 8 modules Yingli Yl245P-29B.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62280	10041-20000-04531	6400 N OWENSMOUTH AVE	91367	3	180B105    64	2146005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM	04/19/2010 12:00:00 AM		Permit Finaled	05/20/2010 12:00:00 AM	ADDRESS	34.18653	-118.6013	new bike shop of new 400 amp service service and 200 amp service future store. The future store will be full plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62281	16041-20002-20065	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Approved	05/01/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	5/1/2017changes to an approved set of plans. corection from suite 100 to suite 103.this is plan check only.(((PLANCHECK FOR POWER AND ENERGY ON PLAZA LEVEL. TENANT IMPROVEMENT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62282	17041-10000-38816	15555 W ROSCOE BLVD	91343	6	192B145   380	2654028022	[T][Q]CM-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.22156	-118.47176	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ FT 47875.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62283	15041-10000-15274	5340 S ALLA ROAD	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM			PC Approved	05/19/2015 12:00:00 AM	ADDRESS	33.9773	-118.42567	PLAN CHECK FOR ENERGY ONLY. ADDING DIMMER TO LOBBY AREA AND RECONNECTING NEW LIGHTS TO EXISTING CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62284	19041-10000-35745	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Echo Park, Historic Cultural North	YES	1977.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	08/24/2020 12:00:00 AM	ADDRESS	34.07196	-118.24719	FULL PLAN CHECK FOR TI WITHIN DODGERS STADIUM CENTER FIELD PAVILIONS AND OUTFIELD PLAZA. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 111,328 SQ.FTBuilding Permit: 19014-10000-03062	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62285	17041-10000-04875	2121 S AVENUE OF THE STARS 32ND FLR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.05554	-118.41342	T24 ENERGY ONLY FOR REMODEL OF BATHROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62286	10041-20000-17106	1605 W COLORADO BLVD	90041	14	162A225    47	5669016018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM	09/02/2010 12:00:00 AM		Permit Finaled	10/20/2010 12:00:00 AM	ADDRESS	34.13968	-118.20125	Plan check T-24 Energy for office building TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62287	13041-10000-04043	11401 W MISSISSIPPI AVE	90025	11	126B153  1038	4261035020		West Los Angeles				2677.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.03844	-118.44463	PV1 for 2 story house. 26 modules 1 inverter. [Solar Module: Innotech Solar 230 Module. Model#: 230W Module] [Inverter: Solar Edge. Model#: SE6000US]. Transformerless inverter. Total system size: 5.98KW system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62288	12041-10000-15306	4161 S MAIN ST	90037	9	114A203    74	5111019013	[Q]CM-1VL	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.00781	-118.27418	Service upgrade to 600A. Loads are existing. METHANE ZONE, however service is from overhead.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62289	13041-10000-35606	11995 W BLUFF CREEK DR BLDG #4	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  36760 SF WITH NEW SURFACE PARKING LOT. TITLE 24 ENERGY FEE CHARGED UNDER BUILDING 3.  3 TOTAL BUILDINGS.  THIS IS BUILDING 4/5 IN THE SAME PARCELBLDG PERMIT: 13010-10000-04244	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62290	18041-10000-14186	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.04337	-118.23442	PC FOR FIRE ALARM  SYSTEM REPLACMENT. SCOPE INCLUDES NEW FACP AND DEVICES WITH EXISITG DEVICES CONNECTD. TOTAL DEVICE COUNT  90  WITH 5 PANELS (4 RPS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62291	13041-20000-30013	3600 N MOUND VIEW AVE	91604	2	159B165    31	2376018017	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.13583	-118.39339	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. 18 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62292	15041-20003-09662	1075 W CHILDS WAY	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	03/18/2016 12:00:00 AM	ADDRESS	34.02304	-118.29105	03/18/2016 Changes to an approved set of plans. All changes have been clouded. Changes include the removal of an elevator lift, changes to lighting and fixture types. 02-04-2016 Changes to approved set of plans. Changes include remove lighing fixture F12 and add 5 F9A fixtures. Changes have been clouded{{{{{{{10/05/2015 Changes to an approved set of plans. All changes have been clouded. Changes include the addition of equipment, revised panel schedules, and revised lighting. Title 24 Compliance Forms have been updated.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.   TENANT IMPROVEMENT FOR MARKS TENNIS STADIUM IN USC. 9750 SQFT INDOOR AND 5500 SQFT OUTDOOR.}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62293	18041-10001-08139	2833 S WIGTOWN ROAD	90064	5	126B161   581	4318018024	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM			PC Approved	12/31/2018 12:00:00 AM	ADDRESS	34.03816	-118.41265	CHANGES TO AN APPROVED SET OF PLANS. SHEET 2 IS NOW REFLECTING PREVIOUSLY APPROVED AC DISCONNECTS. _________________________________________PC FOR POWER ONLY, SCOPE OF WORK INCLUDES NEW ENERGY STORAGE SYSTEMS AND LOAD CENTER. TOTAL SYSTEM SIZE IS 27KWH/14KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62294	12041-10000-14495	4223 S GLENCOE AVE	90292	11	105B153    16	4230005037	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	33.98778	-118.44107	PLAN CHECK T24 ENERGY FOR  LIGHTING IN THE  KITCHENTTE AREA ON FIRST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62295	17041-20000-29979	23044 W ERWIN ST	91367	3	177B097   285	2039009018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.18266	-118.62917	Plan check for a PV1 roof-mounted PV system. System size is 10.9 kWac and consists of (39) modules, (39) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62296	17041-10001-32893	200 WORLD WAY Gate 27B	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC for relocation of three loads to distribution board 2HPCA1 and addition of details for junction boxes and grouding in LAX. All changes clouded. Applicant took plans to Mehdi as requested by Mehdi.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62297	15041-20001-11745	6250 N TOPANGA CANYON BLVD F-1505	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.18498	-118.60554	07-22-2015 Change to approved set of plans, changes include change from 1 transformer to 2 transformers and 1 addition panel, changes apply to delta 5 only [[[[[T. I to new commercial building (restaurant and bar). Plan check for power and energy. Total sqft. 3200]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62298	16041-30000-29091	1999 S AVENUE OF THE STARS 28th FL	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	11/07/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check Title 24 only in existing space T.I. in office area Total area: 5,760 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62299	15041-10000-04755	3905 W 6TH ST	90020	10	135B193   861	5503019010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			Corrections Issued	02/18/2015 12:00:00 AM	ADDRESS	34.06364	-118.30812	ALTERATIONS INSIDE A COFFEEE SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62300	10041-10000-20997	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	03/15/2011 12:00:00 AM		Issued	03/15/2011 12:00:00 AM	ADDRESS	34.01925	-118.37654	Installing new panels, circuits, and electrical system to feed the DC sytem. This system is provide the back up power of the Cable Tv facility. Plan check is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62301	16041-10000-18065	700 S FLOWER ST #2995-29FL	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDIGN ON THE 29TH FLOOR OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2357 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62302	14041-20000-32218	18528 W SHETLAND PL	91344	12	219B125   143	2601075028	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.29517	-118.53618	PV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC USING 16 MODULES. USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.THIS PERMIT FOR THE NEW 3.6KW SYSTEM. OVERALL THIS IS AN ADDITION TO AN EXISTING SYSTEM. PC FOR NEW SYSTE, AND TOTAL INTERCONNECTION.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62303	16041-10000-40389	5200 W CENTURY BLVD	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	33.94516	-118.37049	FULL PC FOR POWER AND ENERGY. CHANGE OF USE, FROM AN OFFICE TO GYM WITHIN AN EXISTING OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND CIRCUITS. A-OCCUPANT LOAD >100.TOTAL AFFECTED AREA IS 5060 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62304	14041-20000-07577	11375 N STRANWOOD AVE	91344	12	213B145   194	2662003020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.27748	-118.47224	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62305	15041-10000-39713	850 W COLORADO BLVD 1-10	90041	14	162A231    43	5709003041	[Q]CR-1VL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			PC Info Complete	11/24/2015 12:00:00 AM	ADDRESS	34.13976	-118.1845	PC FOR SERVICE UPGRADE OF APARTMENT COMPLEX. NO NEW LOADS. CHNAGE OUT TO NEW 600A SERVICE AND NEW SUBPANELS FOR UNITS. RECONNECTING EXITING DWEELING UNIT SUBPANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62306	19041-20001-50604	5113 N NEWCASTLE AVE	91316	5	171B125   785	2181002022	R1-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM			PC Approved	12/27/2019 12:00:00 AM	ADDRESS	34.16237	-118.52524	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM AND ESS. PV SYSTEM SIZE IS 10.17/9.7 KW AC CEC. ESS SIZE IS 40.5 KWH. SCOPE OF WORK CONSISTS OF (174) ROOF TILE PV MODULES, (4) PANELS, (3) 13.5 KWH BATTERIES, AND (2) 5.2 KW INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62307	19041-20001-01455	4157 S MARCASEL AVE	90066	11	111B157   683	4233015010	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	33.99967	-118.42206	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGES MADE TO SINGLE LINE DIAGRAM AND ROOF LAYOUT PAGE. UPDATE TO INDEX, RELOCATION OF LOADS, ADDITION OF A PANEL TO DIAGRAM, CHANGE TO PANEL SIZES, CONDUCTOR SIZES, AND ADDITION OF NOTES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62308	14041-10001-27782	11423 W VANOWEN ST	91605	2	183B169   471	2320003025	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			PC Approved	12/23/2014 12:00:00 AM	ADDRESS	34.19416	-118.38009	(EXPEDITED PER APPLICANTS REQUEST)PV 2 system. Roof mounted. Negatively grounded, central inverter system.1,078 modules, 1 inverter, and i AC disconnect for a 269,500 kW system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62309	14041-10000-15250	1930 W WILSHIRE BLVD 14th floor	90057	1	132A203    41	5142002019	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.05713	-118.27464	Plans  10041-10-21153 were approved but expired. Resubmitted copy. .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62310	11041-10000-17299	18519 W VICTORY BLVD	91335	3	180B125   631	2127011022	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.18676	-118.53663	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62311	12041-10001-01358	10311 S WESTERN AVE 1-63	90047	8	091-5A193 277	6058007004	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Apartment			03/14/2012 12:00:00 AM			PC Approved	12/13/2012 12:00:00 AM	ADDRESS	33.94282	-118.30934	Supplemental application. Major revision to orginal submittal. Plan check power, energy, for new 4-story 63-unit apartment building TO BE LOCATED IN THE METHANE ZONEPERMIT TO BE OBTAINED ON 12041-10000-01358.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62312	14041-20001-05222	5817 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97377	-118.41988	**EXPEDIE FEES**PV1 TRANSFORMERLESS SYSTEM.  TOTAL SYSTEM SIZE 3 KW A/C	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62313	18041-10000-48946	1605 W GRAFTON ST	90026	13	141A209   245	5419009018		East Los Angeles	SILVER LAKE-ECHO PARK- ELYSIAN VALLEY	GREATER ECHO PARK ELYSIAN	YES	1974.20	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.08087	-118.25524	***REPLACING THE LOST APPROVED PLANS*** ORIG EPC APP#: 16041-10000-45180FULL PC FOR NEW MIXED USED APARTMENT BUILDING (35 STUDIO DWELING UNITS AND 3 RETAIL UNITS) 3 STORIES. SERVICE @ 3PH 2000A 120/208V. Building #16010-10000-04687.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62314	15041-10000-28482	1115 W SUNSET BLVD	90012	1	136-5A211 440	5406020003	C2-2D	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.06687	-118.24925	TI TO (E) CAFETERIA FOR OFFICE USE ONLY. NO CHANGE IN PARKING ENTERPRISE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62315	11041-20000-07505	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM			PC Approved	05/20/2011 12:00:00 AM	ADDRESS	34.08363	-118.32191	As built drawings plan check.  Permit is existing.  Plan check requested per inspector.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62316	11041-20000-24553	2151 S AVENUE OF THE STARS 1-375	90067	5	132B161   193	4315019006	R4-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	11/16/2011 12:00:00 AM		Permit Finaled	01/17/2012 12:00:00 AM	ADDRESS	34.05439	-118.41225	energy plan check gift shop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62317	16041-20001-05773	1377 N SERRANO AVE FLOOR 1-3	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.0965	-118.30717	[[[[CHANGES TO APPROVED SET. CHANGES TO  SINGLE LINE ARE CLOUDED IN 3 SEPARATE PAGES . CHANGES TO FEEDERS BACK TO CORE AND SHELL SIZES.   CHANGES IN 1ST PAGE FLOOR 1, 2ND PAGE FLOOR 2, 3 PAGE FLOOR 3.  AS-BUILT DESIGN - CHANGES AFFECT SLD ONLY.]]]Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement/chance of use from motion picture film editing to office to floors 1 - 3 (building has a total of 6 floors). Total lighting area = 62,311 sq. ft. PLANCHECK ONLY FOR ALL 3 FLOORS.PERMIT FOR 1st FLOOR  UNDER  # 16041-20000-08761 ( 1ST FLOOR: 20,823 SQFT)PERMIT FOR 2ND FLOOR UNDER #16041-20000-08764 ( 2NDFLOOR: 20,986 SQFT)PERMIT FOR 3RD FLOOR UNDER #16041-20000-08766 ( 3RD FLOOR: 20,502 SQFT)Note: Building application has been generated under 16016-10000-03638 (1st Floor), 16016-10000-03605 (2nd Floor), and 16016-10000-03607 (3rd Floor).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62318	16041-10000-28148	3220 S HELMS AVE	90034	10	123B169  1779		[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Closed	05/21/2024 12:00:00 AM	ADDRESS	34.03063	-118.3845	Full plan check. Change of use from retail store to a restaurant/bakery use. Upgrading to new tenant switchboard rated at 1000 amps 120/208V 3 phase 4 wire being fed by an existing main service rated at 2000 amps. All new electrical equipment under this new switchboard. Total sqft = 12148.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62319	17041-10000-18144	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	PLAN CHECK FOR T-24 ONLYFOR TI IN EXISTING BUILDING . TOTAL AFFECTED AREA 180 SQ . FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62320	19041-20000-00303	7501 N GLENOAKS BLVD	91504	2	186B181   296	2401042013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1021.04	Electrical	Electrical	Commercial			01/03/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.20677	-118.34209	ti to an existing commercial building (hotel).  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62321	12041-10001-09337	5168 E HUNTINGTON DR SOUTH	90032	14	144A235   165	5219001030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.08911	-118.16978	03/30/16Changes to an approved set of plans. All changes are made under delta 3. Changes include removing the optional standby generator from the single line diagram and floor plans. NOTE: permit pulled under PCIS#12041-10000-09337 (((((PLAN CHECK POWER AND ENERGY MARKET BLDG. TWO 600A SERVICES SUPPLYING BUILDING. MODIFICATION TO SEPERATE FIRE ALARM AND TWO SERVICES FROM UTILITY HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62322	16041-10000-11210	2301 S WESTWOOD BLVD	90064	5	126B157   657	4322003019	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM			PC Info Complete	06/09/2016 12:00:00 AM	ADDRESS	34.04219	-118.43055	PC FOR POWER. SERVICE UPGRADE FROM 200 A TO 800A. ADDITION OF 7 MORE PANELS. PANEL U IS MISSING SCHEDULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62323	19041-10000-05574	515 S FLOWER ST Ste. 1150	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	FOR TENANT IMPROVEMENT WORK ON 2,080 SF OF THE TOTAL FLR AREA. NEW WALL, POWER, LIGHTING, AND FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62324	16041-10000-03706	1076 W 39TH PL	90037	8	117B197  1014	5037021002	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Expired	03/12/2018 12:00:00 AM	ADDRESS	34.01402	-118.29399	PV2, ROOF MOUNTED SOLAR SYSTEM TO A TRIPLEX BUILDING. (17) MODULES (1) 3.6KW INVERTER. TOTAL SIZE 3.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62325	16041-20002-43148	6225 N CORBIN AVE	91356	3	177B117   332	2153022004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Issued	02/15/2017 12:00:00 AM	ADDRESS	34.18332	-118.56246	changes to an approved set of plans.  changes include replacing solar panels to trina solar 255W.system size 3.8kw AC/ 4.59kw DC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62326	15041-20000-13398	14441 W ROSCOE BLVD	91402	6	192B149   361	2638022044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.22172	-118.44798	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is the installation of lighting and receptacles. Total lighting area = 1,440 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62327	18041-20001-40121	15330 W RAYNETA DR	91403	4	163-5A145  40	2281010004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.14386	-118.46715	12/28/2018changes to an approved set of plans.  changes to reflect field conditions. this is paln check only.   (((Plan check for PV roof mounted system, system size: 18 kW with 50 PV Modules and 2 inverters(7.6kW) connected to 200A Panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62328	13041-10000-30358	15800 W ARMINTA ST	91406	6	189B141   163	2206002032	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.21378	-118.47701	PLAN CHECK FOR TITLE 24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 9112 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62329	13041-20000-17486	20648 W CHATSBORO DR PV-1	91364	3	166-5A111  80	2174013017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.1504	-118.58426	PV-1. MIcroinverters. 10.32kW total AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62330	17041-30000-16777	8201 N SEPULVEDA PL	91402	6	192B145   553	2654035035	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	34.21987	-118.46643	Plan check for PV roof mounted system. System size: 10KW with 1 inverter 10kW and 32 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62331	17041-10000-15316	125 W 4TH ST	90013	14	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			05/09/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.0488	-118.24807	Installation of new fire alarm system for conversion of 12 story building to 188 unit live/work apartments with ground floor retail.  Highrise voice evacuation system.  Total system size = 672 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62332	08041-20003-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	07/19/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Bulletin 185-TI , replace lighting.  *****NEW HIGH RISE BUILDING - MEDICAL OFFICE (SHELL ONLY)VARIANCE FOR DEFERRED APPROVAL OF FIRE ALARM SYSTEM WAS SUBMITTED.P/check is approved subject to the ""Conditions of Approval"" on a request for modification regarding campus style feeder to a fire pump.*****"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62333	19041-20000-08390	12650 W FOOTHILL BLVD	91342	7	216B161   753	2527011032	[T][Q]M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	08/18/2022 12:00:00 AM		Permit Finaled	12/01/2022 12:00:00 AM	PIN	34.28929568	-118.41140438	Plan check for power and energy for manufacturing Building with Mezzanine with 1200 A  120/208 Volt. Service. Total area:13,132 sq ft. B#18010-20000-05829	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62334	17041-20000-40209	13449 W INWOOD DR	91423	4	162B157   574	2373027025	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.14052	-118.42589	Plan check for solar pv system, roof-mounted array on SFD.10.4kW ungrounded system. Derating main to 175A. (2) 5.2kW inverters.(37) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62335	15041-10000-08760	656 E 61ST ST	90001	9	105B205   602	6007009007	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	33.98428	-118.26297	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES, TOTAL AREA 4012 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62336	16041-10000-00309	3143 S LA CIENEGA BLVD A-B	90016	10	123B173  1581	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.02974	-118.37234	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL AFEECTED AREA IS 4632 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62337	17041-10000-05474	777 S ALAMEDA ST Basement-1st Floor	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Issued	09/27/2017 12:00:00 AM	ADDRESS	34.03396	-118.24117	Plan check for power and energy T.I. project n existing core and shell building on basement and 1st Floor. Scope of work consist of Bakery/Restaurant, Coffee Shop connect to 2,500A  277/480 V Switch gear and distribution. Total area: 34,234 sq ft. B#17014-10000-00326	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62338	19041-10000-24725	7977 W MELROSE AVE	90046	5	141B177   542	5527013024	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.08392	-118.36356	Energy plan check for an existing retail space T.I. Scope includes new lighting and equipment with a total lighting area of 1709-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62339	13041-10001-35393	3436 N LINDA VISTA TER	90032	14	142-5A235  96	5219012014	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.08578	-118.17123	Expedited RSES plan check per applicant request.{{PV1, Install 4 kW DC roof-mounted solar array, interconnect with main service panel for a one story house. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62340	16041-20000-19767	19929 W ELM PL	91326	12	213B113   320	2701057***	C4-2D, PF-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.27974	-118.56995	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.32 KW CENTRAL INVERTER .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62341	15041-10000-12038	13333 W RIVERSIDE DR	91423	4	168B157   293	2359019008	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.15778	-118.4239	IN A RITE AID STORE, REPLACING LUMINAIRES WITH LED DOWN LUMINAIRESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62342	18041-10000-28428	1803 S WESTERN AVE	90006	10	126B193   612	5073013011	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.04154	-118.30923	T-24, PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW CIRUITS AND RECEPTACELS TO AN EXISTING RETAIL SPACE. TOTAL SQ. FT. 9980.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62343	18041-20001-03550	20341 W VIA SANSOVINO	91326	12	219B113   264	2701061004	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM			PC Approved	10/19/2018 12:00:00 AM	ADDRESS	34.29683	-118.57696	10-19-2018 Changes to an approved set of plan. Changes include equipment interconnection layout changes. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62344	17041-10000-25761	222 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.05621	-118.25318	PC for T24 only for new hallway lighting and facade lighting. Total affected area 18858 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62345	19041-10000-00392	1530 S GLYNDON AVE	90291	11	114B149  1042	4244017001	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	03/23/2019 12:00:00 AM	ADDRESS	34.00487	-118.45623	Plan check for adding (2) new energy storage to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62346	14041-10003-24238	2725 N HYPERION AVE	90027	4	151-5A205 224	5433026037	C4-1D, P-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Approved	06/16/2016 12:00:00 AM	ADDRESS	34.10747	-118.27223	6/16/16: Revision to approved set noted under Delta-2, consits of: Tap conductor run overhead per LADWP request, load changes, and revision on light fixtures schedule (T-24). Permit shall be under 14041-10001-242385/25/16: Sbmittal 2 zero fee due to readjustment of initial submittal (DM).05/12/16Changes to an approved set of plans. Changes include adding a 600A distribution board, 4 new subpanels, replacing light fixtures,  and new load equipment. [New Engineer under the same company is responsible for this change.](((((PC FOR POWER AND ENERGY. TI for SUPERMARKET.  TOTAL AREA 19154 SQ FT. INSPECTOR TO VERIFY CUSTOM FIXTURES.PER 2013 ENERGY CODE.B# 14016-10000-17809.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62347	14041-10000-01134	1505 E 1ST ST	90033	14	129A219    65	5173031902	[Q]M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.04761	-118.22376	Alteration to office space in one story building for City of Los Angeles.Total  area 600 sq ft. Plan check for T24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62348	19041-10000-46921	10958 W STRATHMORE DR	90024	5	135B149   355	4363008002	[Q]R4-1VL	West Los Angeles	Westwood	North Westwood		2653.05	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.0666	-118.44974	NEW PV1 INSTALLATION WITH A SYSTEM SIZE OF 5.1KW DC/ 3.8KW AC,  WITH 1 CENTRAL INVERTER  (SE-3800H-US), 17 MODULES (HIS-S300RG),  AND 17 POWER OPTIMIZERS (P320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62349	15041-10002-08918	454 E COMMERCIAL ST	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	12/22/2016 12:00:00 AM	ADDRESS	34.05313	-118.23621	Suplemental to approved set of plan. pv2, original plan was lost.( The applicant has copy of the approved set). Plan check only. <<<<<<PV2, INSTALL 80 KW AC ROOF-MOUNTED SOLAR ARAY ON ROOF OF THE PARKING STRUCTURE. TIE WITH MAIN 3000 A SERVICE PANEL. (376) MODULES AND (4) INVERTERS 20KW. ONE PART OF E COMMERCIAL ST PROJECT FOR PUBLIC WORK BLDS.{{THIS JOB RELATED TO 462 & 518 E COMMERCIAL ST.}}>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62350	19041-30000-22648	5122 W MAPLEWOOD AVE	90004	4	141B189   932	5522016116	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	04/25/2020 12:00:00 AM	ADDRESS	34.08019	-118.31434	Plan check for a fire alarm system for a 5-story, 24-unit apartment building. Fire alarm system consists of (1) FACP and (82) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62351	17041-20004-41621	12700 W VAN NUYS BLVD bldg 11,12-,13	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			01/22/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.27528	-118.4092	Revisions to approved set of plans.  Delta-4 revisions only.  Addition of PV production meter and miscelleneous SLD revisions.  (((pv2install roof mounted pv system sized 32.8kw interconnected with msp.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62352	12041-10000-22232	9779 W OAK PASS ROAD	90210	5	156B157   467	4385013004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2012 12:00:00 AM			Reviewed by Supervisor	10/03/2012 12:00:00 AM	ADDRESS	34.11983	-118.42761	NEW 800 AMP SERVICE FOR A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62353	18041-10001-00850	1030 N SWARTHMORE AVE SP2-108	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR CHANGES TO APPROVED SET UNDER DELTA  2SCOPE INCLUDES  CHANGES TO EQUIPMENT AND LIGHTING PER OWNER.PC FOR POWER AND ENERGY. INTERIOR REMODEL OF EXISTING RETAIL SPACE WITHIN EXISTING MALL. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 2736 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62354	15041-10000-34621	13449 W SHERMAN WAY	91605	2	183B157    25	2328026011	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.20135	-118.426	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62355	17041-10000-26095	7400 N JORDAN AVE	91303	3	186B105   559	2111009018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Issued	08/01/2017 12:00:00 AM	ADDRESS	34.2051	-118.60274	TITLE 24 PLAN CHECK FOR REMOVAL OF (16) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA = 37,100 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62356	16041-10000-24172	1331 1/2 S MENLO AVE	90006	1	129B197  1232	5056001041	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.04633	-118.29067	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(14)CANADIAN SOLAR CS6P-260P(1)INVERTER-SOLAREDGE SE3800-A-US(14)SOLAREDGE P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62357	16041-10000-21420	1434 W 214TH ST	90501	15	051B193   591	7349023007	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	33.8344	-118.30282	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(11)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-SOLAREDGE #SE3000-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62358	17041-10000-07222	13425 W SHERMAN WAY	91605	2	183B157    25	2328026011	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.20136	-118.42552	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 24375 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62359	11041-20000-25401	13275 N GOLDEN STATE RD	91342	7	225B141  1516	2604002059	(Q)M1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	11/29/2011 12:00:00 AM		Permit Finaled	01/11/2012 12:00:00 AM	PIN	34.31226914	-118.48573073	New fire monitoring system and tying into the fire sprinkler system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62360	16041-10000-35586	8561 N DE SOTO AVE	91304	3	192B109    13	2779005039	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.22	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.22628	-118.5888	TITLE 24 FOR EXISTING (LOW RISE) COMMERCIAL BUILDING.  SCOPE OF WORK INCLUDES REMOVAL  OF HID LIGHTS AND INSTALLTION OF 10 LED FIXTURES.TOTAL SQ. FT. 45225	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62361	11041-20000-01751	1410 S ABBOT KINNEY BLVD	90291	11	108B145  1421	4238004052	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM			PC Info Complete	02/03/2011 12:00:00 AM	ADDRESS	33.99043	-118.46567	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62362	18041-10000-01058	725 S FIGUEROA ST	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM			PC Info Complete	01/26/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	T-24, PC FOR ENERGY ONLY. SCOPE REPLACING EXISTING LIGHTS IN EXISTING FINANCIAL TRANSACTION SPACE. TOTAL AFFECTED AREA IS 6466 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62363	13041-20000-04720	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Approved	02/25/2013 12:00:00 AM	ADDRESS	34.05554	-118.41342	Change to lighting to an existing office space in a high-rise building.  Load is 30 amps per applicant.  PLAN CHECK ONLY FOR ENERGY, WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62364	18041-10000-39904	4682 E YORK BLVD UNIT 2	90041	1	156A223   141	5474018004	RD3-1, [Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.02	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.12269	-118.21406	TI IN AN EXISTING COMMERCIAL SPACE USED AS A  MASSAGE PARLOR/BEAUTY PARLOR. T-24 ENERGY ONLY. 596 SQR FT. BUILDING PERMIT: 18016-10000-28860	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62365	13041-10000-32568	860 S BROADWAY #862&860	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM			PC Approved	11/20/2013 12:00:00 AM	ADDRESS	34.04235	-118.2558	TWO ADJACENT TENANT SPACES ;PERMIT WAS OBTAINED ON 13041-10000-27312PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62366	14041-10005-28878	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE RELOCATION AND ADDITION OF NEW LIGHTING(T-24), ADDITION OF NEW CIRCUITS, FIRE SMOKE DAMPERS, TRAP PRIMERS, FAN COILS AND ELECATOR CURTAINS. CHANGES ARE ALL UNDER DELTA 25 PACKAGE 4. RELATED PLAN CHECK NUMBERS 14041-10005-26004 (NEW CIRCUITS, PANELS, BRANCH CIRCUITS, & T-24)16041-10004-15547(SINGLE LINE DIAGRAM)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62367	16041-20000-15151	19427 W KILFINAN ST	91326	12	219B117    61	2701020010	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.29724	-118.55699	PV1.  Install 6.3 kW rooftop mounted PV system.  (21) modules with (1) 6 kW rated central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62368	16041-10000-44021	1776 N LAS PALMAS AVE	90028	13	150A185   314	5547003904	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.10406	-118.33602	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 8075	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62369	12041-10000-19362	8762 N CORBIN AVE	91324	12	195B117   156	2783025095	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			08/16/2012 12:00:00 AM			PC Approved	09/12/2012 12:00:00 AM	ADDRESS	34.22956	-118.5621	PLAN CHECK T24 ENERGY/EMERGERNCY TENANT IMPROVEMENT TO EXISTING RETAIL SPACE (ANNA'S LINENS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62370	18041-20000-00664	110 W 11TH ST Ste 450	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.0392	-118.25858	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62371	10041-20000-06076	3000 W SLAUSON AVE	90043	8	108B189  1426	4005010004	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00, 2347.00	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	04/05/2010 12:00:00 AM		Permit Finaled	07/16/2010 12:00:00 AM	ADDRESS	33.98891	-118.32567	lighting and some receptacle for car shop in office area. this plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62372	16041-10000-27436	12740 W ARROYO ST BUILD. C	91342	7	219B161   249	2525027014	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.29585	-118.41002	Plan check for T-24 only.  Remove indoor and outdoor HID fixtures and replace with new LED fixtures. Affected area: 44,144 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62373	19041-20000-32507	1505 N EDGEMONT ST	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	01/06/2021 12:00:00 AM	ADDRESS	34.09843	-118.29637	PLAN CHECK FOR 1 TO 1 REPLACEMENT OF FLUOROSCOPY EQUIPMENT, OUTLET, AND A EF, NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62374	18041-20000-11375	5936 N MAURY AVE	91367	3	177B085   521	2032017002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.17819	-118.66085	pv1install roof mounted pv system sized 17.4kw interconnected with msp.permit fee $0.00 by state senate bill no.1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62375	16041-10001-41570	1625 W OLYMPIC BLVD 9TH FLR	90015	1	130-5A203 305	5137002033	C2-2D, C4-2D	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.04973	-118.27494	Supplemental PC for lost set of plans for bathroom TI on 9th flr. PC for lights and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62376	14041-20000-14451	8319 W UTICA DR	90046	4	151-5A175 203	5567021045	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.10842	-118.37194	PV1.  Install 5.9 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62377	19041-20000-23972	8964 N NEVADA AVE	91304	12	195B101    45	2010021011	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.23368	-118.60707	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 8.25 KW DC/ 7.58 KW AC CEC. SCOPE OF WORK INCLUDES (25) LG ELECTRONICS PV MODULES WITH P370 OPTIMIZERS AND A SE7600H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62378	16041-20000-33596	10895 1/2 W OLINDA ST	91352	6	192B173    21	2408011008	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.22661	-118.36803	pv1install roof mounted pv system sized 3kw, standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62379	17041-10000-09060	13474 W CROWLEY ST	91402	6	192B157  1005	2637013113	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.22462	-118.42679	PV1, INSTALLATION OF A 3.920 KWdc/3.0KWac ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: CANADIAN SOLAR (1) INVERTER: SOLAREDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62380	18041-10000-09038	2907 S VERMONT AVE	90007	8	120B197   145	5054037027	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.02843	-118.29179	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62381	16041-20000-07796	707 N WESTERN AVE	90038	13	141B193   569	5535017007	C4-1D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Issued	03/14/2016 12:00:00 AM	PIN	34.08373106	-118.30949282	TI to (E) retail space for furniture store.  1198 sq. ft.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62382	17041-10000-32232	1700-1722 S SANTA FE AVE	90021	14	120A217    21	5168001004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.02438	-118.22983	TI AND SHELL OUT OF BUILDING. PROVIDING NEW LIGHTING AND CORRIDORS AND RESTROOMS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62383	17041-10000-31776	1206 E 6TH ST	90021	14	126A215   355	5164010003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.03793	-118.23804	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FIXURES FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62384	16041-10000-39634	759 S SPRING ST	90014	14	127-5A211 157	5144015240	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.04329	-118.25367	PC FOR POWER AND ENERGY. T.I. OFFICE TOTAL AREA 8627 SQ FT. (E) MAIN SWITCHGEAR 800A, LOAD >400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62385	18041-20000-35957	15301 W VENTURA BLVD UNIT 320	91403	4	168B145   821	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for Title 24 only office remodel. new lights, existing circuits. Total area: 6021 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62386	11041-10000-21227	3470 S MCCLINTOCK AVE	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Closed	01/15/2013 12:00:00 AM	ADDRESS	34.0236	-118.28768	New 800 ampere contruction temporary service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62387	16041-10000-31972	8486 W 3RD ST	90048	5	138B173   778	5511032028	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			Corrections Issued	10/12/2016 12:00:00 AM	ADDRESS	34.07318	-118.37592	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING RESTAURANT. SCOPE INCLUDES NEW 400A DISTRIBUTION BOARD, NEW SUBPANELS, AND NEW LIGHTS/RECEPTACLES. TOTAL AFFECTED AREA IS 1632 SQ. FT. b#16016-10000-20140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62388	14041-20000-23957	10230 N COZYCROFT AVE	91311	12	204B109   225	2741025026	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.25619	-118.58171	$0 permit fee is due to Senate Bill SB-1222.PV1 SFD. TOTAL SYSTEM SIZE 12.7KW AC USING 53 MODULES. USING ENPHASE M250. MICROINVERTER SYSYTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62389	11041-10000-24005	929 N CYPRESS AVE	90065	1	145-5A219 184	5453022900	[Q]C2-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM			PC Info Complete	12/21/2011 12:00:00 AM	ADDRESS	34.09307	-118.22495	ADD A NEW CLASSROOM IN AN EXISTING BUILDING. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62390	13041-10000-08080			11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN REVIEW OF RFI FILES FOR CHANGES ON SITE DURING THE BRADLEY WEST CORE RENOVATIONS-	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62391	16041-30000-23054	1551 E BAY ST	90021	14	123A215   238	5166035***	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.03171	-118.23689	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES.  PLAN CHECK FOR ENERGY. TOTAL SQUARE FOOTAGE 3520.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62392	12041-10000-15936	8635 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM			Verifications in Progress	08/23/2012 12:00:00 AM	ADDRESS	34.07373	-118.38073	T.I. to an existing Medical Office for Cedars-Sinai.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62393	13041-20000-00183	8426 N PINELAKE DR	91304	12	192B093   194	2005015002	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM			Reviewed by Supervisor	01/17/2013 12:00:00 AM	ADDRESS	34.22203	-118.63745	New 8.4KW rooftop mounted PV system for an existing single family residence.   System is ungrounded/transformerless and uses SolarEdge Optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62394	18041-10000-34132	2025 E ZONAL AVE 5TH FLR	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.05978	-118.20504	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A CLASSROOM/OFFICE SPACE. SCOPE INCLUDES NEW PANELBOARDS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 4528 SQ. FT. B#18016-10000-28588	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62395	17041-20000-27510	6711 W FOREST LAWN DR	90068	4	165B185   188	5581028007	C1-1D-RIO	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.14499	-118.33842	TI to (E) restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62396	14041-10000-05053	1900 AVE OF STARS A LEVEL-1TH FLOOR	0	5				West Los Angeles				1435.00	Electrical	Electrical	Commercial			02/24/2014 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM				T24 ONLYWITH EMERGENCY LIGHTING  FOR A COMMERCIAL BUILDING. TOTAL AREA IS 395 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62397	17041-10001-22110	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	Changes to an approved set of plans. All changes are clouded under delta 7. Changes include connecting emergency lights and exit signs to building emergency geneator circuit as second source of power. Removing inverter as emergency power from scope of work.   Note: Permit is paid under master application PCIS#17041-10000-22110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62398	09041-10001-24286	380 W WORLD WAY SOUTH-CONCOURSE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/09/2010 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans for the  south concourse of TBIT- Revisions are noted in bulletins ( GB1to GB5 ). On the plans, each change is clouded and noted to the reference GB.Job is approved after talking to francis that PCIS was not updated at the time.  (nabil)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62399	17041-10001-07892	8564 S BROADWAY	90003	9	097-5A203 324	6040010015	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	33.9604	-118.27809	Title 24 plan check.  New outdoor lighting for existing bank.  Total area = 40,299 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62400	17041-10000-45137	1030 W 58TH ST	90037	9	108B197  1440	5002016033	P-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	33.98956	-118.29272	Plan check for PV roof mounted system. System size: 3.6kW with 16 modules and 1 inverter(3.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62401	16041-10000-11201	8814 N HAYVENHURST AVE	91343	12	195B137   565	2688034006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Expired	05/02/2018 12:00:00 AM	ADDRESS	34.23074	-118.49367	PV1, solar installation 3.225 kW AC(15) HiS-S260RG(15) M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62402	15041-10001-37848	514 E COMMERCIAL ST bus wash	90012	14	130-5A215  66	5173002901	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05289	-118.23439	PC only due to lost approved set.This is 4 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************ONE-STORY BUS WASHSEE 15010-10000-01118	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62403	18041-20001-05249	6002 N LAUREL CANYON BLVD	91606	2	177B165   683	2333013020	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Approved	06/21/2018 12:00:00 AM	ADDRESS	34.17976	-118.39631	06/21/2018 Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from restaurant to massage parlor/tenant improvement. Total lighting area = 1,098 sq. ft.Note: Building permit has been issued under 17016-20000-38018*****Previous Work Description*****(9) RECEPTACLES (3) LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62404	14041-10000-14395	1131 S WESTWOOD BLVD	90024	5	132B149   100	4363023029	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.0601	-118.44538	PLAN CHECK FOR ENERGY ONLY FOR RESTAUART PIZZERIA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62405	17041-10000-45978	7868 N DEERING AVE	91304	3	189B105   397	2109017036	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.21282	-118.59394	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62406	12041-10000-17881	8900 N DE SOTO AVE	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	New 2500A Switchboard, motor loads, and panel.  Service upgrade and Main Switchboard are on application 12041-10000-09968	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62407	10041-10000-07457	800 E 12TH ST 1-119	90021	9	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	05/03/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	fIRST TIME TENANT, POWER LIGHTING AND TITLE 24. PANELS AND XFMR EXISTING. UNIT TO BE INSPECTED IS #   116.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62408	19041-10000-30244	1348 S BURNSIDE AVE	90019	10	129B177   828	5085036010	R3-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Apartment			08/05/2019 12:00:00 AM	01/08/2021 12:00:00 AM		Permit Finaled	12/06/2021 12:00:00 AM	ADDRESS	34.04936	-118.35417	Full plan check for a new  unit apartment. Scope of work includes a new 400A service single phase 3 wire. Note performance method is used for T24. B#: 19041-40000-03325	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62409	17041-10001-12956	767 S ALAMEDA ST Building 2	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Info Complete	10/06/2017 12:00:00 AM	ADDRESS	34.03474	-118.24063	Changes to approved plans. T-24 energy only. New receptacles and lights in the Ground Floor & Basement and 2 New Circuits. NO NEW PANELS were added.  Total area = 10872 sq ft.B # 17016-10000-07493	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62410	18041-10000-20832	1621 S LELAND ST	90731	15	012B193   567	7458027012	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	33.72929	-118.30134	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER AND POWER OBTIMIZERS. (23) MODULES AND (1) 5.0 INVERTER. TOTAL SYSTEM SIZE IS 5KWAC AND 6.67KWDC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62411	17041-10000-01879	7230 N BELLAIRE AVE PV	91605	2	186B161   577	2324003048	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.20224	-118.4093	0$ total permit fee per state senate bill 1222PV roof mounted installation to a commerciall building. (19) Central inverters for a total system size of 615 KW, (2204) Solar modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62412	19041-10000-47508	1818 W 62ND ST	90047	8	105B193   766	6001016011	M2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Expired	02/01/2023 12:00:00 AM	ADDRESS	33.98328	-118.30969	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62413	12041-20000-02295	14925 W BURBANK BLVD	91411	2	174B149   809	2243010027	C1.5-1VL, R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.17229	-118.4584	T.I. to medical space.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62414	11041-20000-19978	1026 W 34TH ST #204	90089	9	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM			PC Approved	09/20/2011 12:00:00 AM	PIN	34.02400284	-118.2895744	Plan check T24 Energy/Emergency lighting for LRC Gym #204 TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62415	13041-20000-34151	4408 E WORTH ST	90063	14	135A229   166	5224005014	M3-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.06245	-118.18956	800A SERVICE UPGRADE FOR FUTURE AUTO REPAIR SHOP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62416	15041-20002-39703	13650 W BURBANK BLVD	91401	4	174B157   611	2344001014	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.17196	-118.43072	02-03-16 Change to approved set of plans. Changese include addition lighting fixtures. Changes apply to delta 1 only.  {{{{{{{Revisions made to approved set.  Inclusion of (E) lighting into lighting plan and change of panel location.  (((PLANCHECK FOR T24 ENERGY. CHANGE OF USE FROM (E) RETAIL TO (N) BEAUTY SALON.  866 SQFT.)))}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62417	15041-10000-27661	777 S SANTA FE AVE ANNEX	90021	14	124-5A217 323	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.03354	-118.23024	RENOVATION OF EXISTING WAREHOUSE CONSISTING OF THREE BUILDINGS. (1) 2 STORY CMU BUILDING(1) 2 STORY ANNEX BUILDING (1) 5 STORY TOWER.COMPLETE REBUILD.  PLAN CHECK FOR POWER AND ENERGY.  THIS APPLICATION TO COVER BUILDING ANNEX ONLY.BUILDING APPLICATION UNDER 14016-10001-21080	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62418	16041-20000-33648	17021 S FIGUEROA ST	90248	15	066B201   218	6121002017	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	33.87643	-118.28255	Remove existing hid fixtures and replace with led.  plan check for energy outdoors only.  total square footage 93500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62419	13041-10000-00254	8400 S VICKSBURG AVE	90045	11	096B165   162	4107031031	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2013 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	33.96242	-118.39432	pv1 system for single family single story dwelling unit using standard plan. 3.024 kW system size utilizing 14 microinverters. inverter - enphase m215 - 60- 2ll-s22. solar panel - rec 245 pe. single string	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62420	11041-10000-22632	8926 W MULBERRY DR	91040	2	207B189   580	2547028045	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	11/02/2011 12:00:00 AM	ADDRESS	34.26419	-118.32642	New 9.66KW Photovoltaic system for a single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62421	17041-20000-28114	12253 N LIMA WAY	91342	7	219B149   931	2611046023		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.29402	-118.45577	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62422	15041-20001-30650	10773 W LAWLER ST	90034	5	120B161   776	4254025040	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.02433	-118.41418	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 13 kWac and consists of (2) inverters, (54) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62423	12041-10000-10625	3316 N EASTERN AVE	90032	14	142-5A233 325	5218014038	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	07/24/2012 12:00:00 AM	ADDRESS	34.084	-118.17786	Plan check T24 Energy/emergency lighting for office spaces. Permit for new light fixtures, unit equipments, and switches.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62424	10041-20000-08638	21031 W VENTURA BLVD #501	91367	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM			PC Approved	05/10/2010 12:00:00 AM	PIN	34.16705846	-118.59120236	T.I. in (E)office suite (approx. 1930 S.F.)  NO CHANGE IN USE/PARKING. This plan check is for title 24 energy only. There is existing permit on 10041-90000-04777.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62425	12041-10000-28348	2231 S BARRINGTON AVE	90064	11	123B149   480	4260012027	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	07/17/2013 12:00:00 AM	ADDRESS	34.03337	-118.44727	Plan check power and energy for existing retail building (Office Depot). TI and replace existing equipment due to fire damaged. UNSIGNED SHEETS OF FAULT CURRENT CALCULATIONS WERE SUBMITTED ON 12/5/12.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62426	13041-10000-07311	960 N TULAROSA DR	90026	13	142-5A203 165	5427030027	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.08564	-118.27864	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW. USING 10 MODULES. TRANSFORMERLESS INVERTER, NONSTANDARD PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62427	12041-20000-21542	16521 W SATICOY ST	91406	6	186B137    22	2205009009	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.20858	-118.49305	TITLE 24 AND POWER OVER THE COUNTER PLAN CHECK. TWO NEW PANELS: LB AND HB.  3053 SQ FT INDOORS+3431 OUTDOORS SQ FT.  REVISION TO APPROVED PLANS (NORTH BUILDING 11041-20000-21212).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62428	14041-20001-13145	20226 W SEPTO ST	91311	12	201B113   112	2741017015	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.25077	-118.57424	Fee for expedite only.****Roof mounted PV system with Optimizers and tranformerless inverter.  System size is 7.4KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62429	13041-20000-14854	16000 W VENTURA BLVD #750	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	ADDRESS	34.15584	-118.48164	Existing office remodel.  Relocating lighting in 3 offices.  Less than 50% lighting change to #752, checked only for Mandatory Measures, per applicant.  Offices #757 & #756 checked for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62430	16041-10000-02819	9759 N SOPHIA AVE	91343	12	201B137   403	2677019036	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Northridge East	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.24808	-118.48814	PV1, ROOF MOUNTED SOLAR SYSTEM, (40) MODULES AND (1) INVERTER- 8KW. TOTAL SIZE IS 8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62431	16041-10000-41965	6500 W WILSHIRE BLVD #2240	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.06371	-118.3703	OFFICE TI. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62432	12041-10000-05326	2320 S COTNER AVE	90064	5	126B153  1146	4322023013	M2-1	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	06/15/2012 12:00:00 AM	ADDRESS	34.03733	-118.43747	Title 24 Energy and Emergency Lighting. Office building. 4030 sqft. Permit for new branch circuits in existing panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62433	14041-20000-23929	17955 W CALVERT ST	91335	5	177B129   191	2123033043	R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM			PC Approved	09/02/2014 12:00:00 AM	PIN	34.18222494	-118.52473236	PV1 - plan check only.Changes to approved set, permit pulled under permit #14041-20000-21101.Approved set did not take into account pre-existing solar array. Plan check for output of new and existing solar arrays together only.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62434	17041-10000-22248	6150 N DE SOTO AVE	91367	3	177B109   226	2149004021	(Q)C4-2D	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Apartment			06/30/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.18226	-118.58998	Title 24 plan check.  Interior T.I. to (E) apartment building clubhouse.  New lighting and receptacles.  Lighting area = 6,623 sq. ft.       Building permit #17016-10000-17966	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62435	18041-20000-39082	16101 W SATICOY ST	91406	6	186B137   423	2205010905	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	34.20863	-118.4842	**Zero dollar permit fee per AB-1414/ SB-1222**Plan check for PV roof mounted and carports system Feed In Tariff (FIT). 4 new PV Carports and  PV mount on existing Aircaft Hangers. System size: 1049.42 KW AC CEC / 992.5 kW AC / 1296.48 KW DC, with 3552 PV modules and (25) 33.3 kW inverter and (8) 20 kW invertersB#18010-30000-04937,18010-30000-04936,18010-30000-04939,18010-30000-04938	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62436	19041-10000-21506	9506 N OBECK AVE	91331	6	198B153    86	2642015008	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.24282	-118.43478	PV1 roof mounted, Scope of work includes 15 modules(Q-peak 285) ,optimizers (SE P320), with a central inverter (SE3800H-US). System size is 3.8KWac/4.275KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62437	14041-10000-35111	14556 W RAYMER ST	91405	6	189B149   555	2210030028	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.21172	-118.45058	T24 only. remove HID light fixtures and replace with new FLUORESCENT fixtures, total area 5550 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62438	14041-10000-28100	3107 W BEVERLY BLVD	90026	13	138A201   209	5156010010	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Closed	07/21/2017 12:00:00 AM	PIN	34.07222667	-118.28234888	Plan check for power and energy for existing commercial building. Single structure with multiple addresses 3107, 3709, 3111, 3113, 3115. Upgrade service to 800amps. Each address shall pull its own separate permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62439	12041-20000-15079	900 S FIGUEROA ST	90015	9	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	34.04604	-118.26272	T.I. to existing high rise building on the partial of 3rd floor (Room number 0306, 0307, 0308, 0316, 0317).  Plan check for energy only.  Permit fees are under Inspection.  ((A DO NOT ISSUE MESSAGE EXISTS FOR THIS ADDRESS, INSPECTOR TO VERIFY))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62440	17041-20000-32354	4115 S REDWOOD AVE	90066	11	108B153   995	4230006017	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	33.99062	-118.44021	Interior TI to existing office space.  3550 SF - plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62441	19041-20000-24206	4335 W CEDARHURST CIR pv1	90027	4	150B201    80	5591007007	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.11121	-118.28435	pv1Installation of a roof mounted pv system on existing sfd. System size 10.56KW DC/10KW AC. Scope of work consists of (32) pv modules with optimizers and a inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62442	11041-20000-23710	8914 W PICO BLVD	90035	5	132B169   900	4305014012	C4-1VL-O	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.05505	-118.3861	energy plan check restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62443	16041-20001-32988	6816 N BELLINGHAM AVE	91605	2	183B165   600	2321026001	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	ADDRESS	34.19456	-118.39857	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.73 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62444	14041-20000-24346	9362 N ROSLYNDALE AVE	91331	6	198B153   436	2642021022	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.24033	-118.43437	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62445	19041-20000-37077	11211 N SEPULVEDA BLVD lot #21	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 2.83 KW DC ROOF MOUNTED PV SYSTEM WITH (9) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62446	15041-20001-41155	333 S HOPE ST FL 55	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM			PC Approved	06/07/2016 12:00:00 AM	ADDRESS	34.05326	-118.25292	[[6/7/16 CHANGES TO APPROVED SET. REDUCTION OF FIXTURES AND CHANGES TO THE LAYOUT]]T.I NON STRUCTURAL PARTITION. PC FOR ENERGY ONLY. TOTAL AREA 1,830 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62447	15041-10000-33431	3366 S MCLAUGHLIN AVE	90066	11	117B157   358	4249006008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	10/08/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.01766	-118.43208	PV1, INSTALL NEW 5.565 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(21) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62448	14041-10000-00435	14722 W TYLER ST	91342	7	225B149   483	2505028024	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.3096	-118.45376	PV1, ROOF-MOUNTED SOLAR INSTALLATION IN SINGLE FAMILY DWELLING UNIT. MICROINVERTER SYSTEM, ON STANDARD PLAN, WITH (10) MODULES ( SOLAR WORLD PLUS SW 250W MONO BLACK) AND (10) ENPHASE M215 MICROINVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62449	19041-20001-31255	10947 W CHALON ROAD	90077	5	141B145    16	4369006013	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.08569	-118.45845	08-14-2019 Changes to an approved set of plan, Changes include PV System reduction to 8.82KW with 28 PV Modules and 1 inverter(7.6KW)Fees $0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62450	16041-20000-07544	11400 W OLYMPIC BLVD Suite 750	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.03666	-118.44346	Plan check for energy only. TI to existing office in high rise building. New lighting (incl. emergency) and receptacles. 2,841sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62451	15041-10002-28019	9220 N WINNETKA AVE	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.23795	-118.57084	CHANGES TO APPROVED SET. PLANCHECK ONLY- CHANGES INCLUDE ADDITION OF 2 NEW PANLES AND NEW LOAD (EV AND LIGHTING) ONLY CHANGES OF DELTA 23 .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62452	13041-20000-01023	300 S GRAND AVE 11th floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM			PC Approved	01/15/2013 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for energy and emergency lighting. 11th floor. 2020sqft. Corridor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62453	18041-10000-01597	6222 W WILSHIRE BLVD STE 210	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.06309	-118.36418	T-24, SCOPE OF WORK INCLUDES NEW LIGHTING WITH EXISTING CIRCUITS TO EXISTING OFFICES. TOTAL SQ. FT. 2822.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62454	17041-10000-45750	4600 W COLORADO BLVD	90039	13	162B205   273	5593018903	PF-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.14094	-118.27314	ENERGY ONLY T24 PLAN CHECK FOR LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 483 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62455	14041-10000-12736	7551 S DUNBARTON AVE	90045	11	102B161   304	4110026001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	33.97128	-118.41031	PV1, INSTALL 4 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL,  WITH OTIMIZEERS AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62456	18041-20000-45334	3731 E OLYMPIC BLVD	90023	14	118-5A227 216	5191003021	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.01901	-118.19522	Plan check for power and energy. Project site is an existing building. Project scope is a changes of use from grocery to (5) live/work units. Work includes a 600 amp service and a total outdoor lighting area of 8,381 sq. ft.Note: Building permit has been issued under 18016-10000-11113	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62457	15041-20000-24374	18340 W VANOWEN ST	91335	3	180B125    42	2125016018	[Q]C2-1L-CDO-RIO, [Q]P-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.19365	-118.5331	PLANCHECK FOR POWER AND ENERGY. T. I. TO (E) RETAIL.  DD'S. DISCOUNT STORE. 24000SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62458	14041-10000-24563	910 S FAIRFAX AVE	90036	4	132B177   328	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM	07/16/2015 12:00:00 AM		Issued	07/16/2015 12:00:00 AM	ADDRESS	34.05978	-118.36284	INSTALLATION OF NEW METHANE MITIGATION SYSTEM.  43 DEVICES , 2 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62459	12041-20001-17436	5031 N ALONZO AVE	91316	5	171B129   362	2182007002	RA-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.16167	-118.52046	Changes to approved set of plans. Removal of office and converted into elevator lift. Changes to some lighting/ no changes to emergency lighting or path(s) of egress. Plan check for energy only.T.I. for library, meeting room, and classroom.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62460	13041-10001-32316	3912 S TIVOLI AVE	90066	11	108B153    84	4236025036	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	33.99533	-118.44228	Expedited RSES plan check per applicant request.(((PV1, Install 4 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 16 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62461	19041-10000-11731	11150 W SANTA MONICA BLVD 12th Flr	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLAN CHECK FOR TITLE 24 ONLY REMODEL PUBLIC CORRIDOR AND RESTROOMS IN A HIGHRISE BUILDING TOTAL EFFECTED AREA 876 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62462	08041-10002-13153	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM			PC Approved	03/22/2010 12:00:00 AM	ADDRESS	34.0965	-118.30717	REVISION OF APPROVED SET OF PLANS- 2 EA NEW PNLBOARDS, NEW CIRCUITS AN A XFMR IN PRINTING ROOM # 4. NO CHANGES TO THE LIGHTING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62463	17041-10000-39485	12832 N BROMONT AVE	91340	7	222B157   383	2513004016	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.30397	-118.42957	Plan check for PV roof mounted system. System size: 3.8kW with 14 modules & 14 power optimizer and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62464	18041-10000-34164	7535 N SAN FERNANDO ROAD	91505	2	186B177   569	2466036009	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.2083	-118.35375	REPLACE INDOOR-OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62465	16041-10000-34402	9338 N ROSLYNDALE AVE	91331	6	198B153   505	2642021026	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2016 12:00:00 AM			PC Approved	09/28/2016 12:00:00 AM	ADDRESS	34.23983	-118.43385	Plan check for PV roof mounted system. System size: 5.0kW with 23 modules and 1 inverter(5.0kW). Standard plan is being use.  Plan check only.  Permit was pulled online under #16041-90000-26067	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62466	16041-20009-12885	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.21922	-118.44896	05-02-2019 Changes to an approved set of plans, Changes include addtion of lighting fixture and replace lighting fixture with different fixture, all changes has been clouded as delta 4 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62467	19041-30000-50033	23938 W JENSEN DR	91304	12	193-5A091 107	2017025032	A1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.22289	-118.64823	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10KWac. SCOPE OF WORK IS 36 MODULES (HANWHA Q-CELLS 315), WITH OPTIMZERS (SE P400), A CENTRAL INVERTER (SE10000H-US).  NO MPU.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62468	19041-10000-05379	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	09/01/2021 12:00:00 AM	ADDRESS	34.0631	-118.36086	FULL PLAN CHECK FOR EXISTING 2 LEVEL RESTAURANT, IN EXISTING MUSEUM. POWER AND ENERGY TITLE 24 INCLUDED. TOTAL SQUARE FOOTAGE = 8093 SFSCOPE OF WORK INCLUDES (3) 75 KVA TRANSFORMERS, (2) 100A PANELS, A 225A PANEL, AND A 200A PANEL.B#19016-10000-03253	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62469	10041-10000-25688	11333 N SEPULVEDA BLVD	91345	7	213B145   166	2664001801	P-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1092.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.27646	-118.46863	Core & shell for a medical building. TI were submitted under separate application. EPC is for Power & Energy. (Variance for a separate fire alarm system was field)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62470	13041-10000-36244	7702 N SALE AVE	91304	12	189B097  1156	2013017009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.21031	-118.6184	"""Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.""Roof mounted PV system with 12.75 KWdc for a one story house.  Install new125A PV subpanel.(2)Transformerless inverter(s): Solaredge SE 6000A-US. (51) Modules: Trina Solar TSM-250PA05.18.(51) Optimizers: Solaredge OP250-LVMC4SM-2NA-Z"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62471	18041-10000-11932	7117 N WOODLEY AVE	91406	6	183B141   222	2224009006	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.19977	-118.48386	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62472	19041-10000-03215	835 W WILSHIRE BLVD	90017	14	130-5A209 194	5144007025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM			PC Info Complete	10/03/2019 12:00:00 AM	ADDRESS	34.05005	-118.25891	FULL PLAN CHECK FOR CONVERTING EXISTING RETAIL SHELL AREA TO 2 LEVEL CVS PHARMACY STORE; SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A 300-KVA TRANSFORMER, 800-AMP PANEL AND OTHER LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62473	19041-10000-08808	3613 S CABRILLO AVE	90731	15	006B197   380	7469020029	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2975.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Expired	10/10/2023 12:00:00 AM	ADDRESS	33.71321	-118.29847	Plan check for a 9.92KW DC / 7.6KW AC roofmounted system with (1) inverter, (32) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62474	15041-20000-43071	11115 W MAGNOLIA BLVD	91601	2	171B173   534	2350018077	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Expired	01/24/2018 12:00:00 AM	ADDRESS	34.16506	-118.37299	Installation of new fire alarm system. (48) Fire alarm devices(1) Fire alarm panel(1) Control panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62475	11041-20000-01687	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	05/07/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	Install new transformer, subpanel, and ckts for Kaiser Permanente (North Building).  Plan check for power only. Fire alarm system plan check fee was included on this plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62476	17041-20000-40430	16534 W GREENLEAF ST	91436	5	168B137   511	2284005012	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Re-Activate Permit	10/01/2019 12:00:00 AM	ADDRESS	34.15575	-118.49345	Addition of (1) tesla power wall to an existing PV system.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62477	19041-20000-19993	7886 N VAN NUYS BLVD	91402	6	189B149   635	2212028018	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	07/02/2020 12:00:00 AM	ADDRESS	34.2144	-118.44789	Renovation of (E) commercial retail tenant space.  600A main distribution panel and associated downstream distribution and loads.  Plan check for power and energy. 47,475 sq ft. B#19016-20000-15758	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62478	18041-20001-23162	1405 S WELLESLEY AVE	90025	11	126B145   822	4267032015	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	12/29/2020 12:00:00 AM	ADDRESS	34.03973	-118.46588	Revisions to approved set of plans.  Addition of kitchen equipment and lighting for hotel food service operation, lighting system revisions, and guestroom typical unit detail changes. Delta A and Delta 2 changes only.(((Plan check for power and energy for change of use from Home of the Age to Hotel mixed use existing building. Total area: 47739 sq ft. B#18016-1000004044)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62479	15041-10000-39486	361 S BROADWAY	90013	14	130-5A211 156	5149015023	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.04977	-118.24943	T-24, CHANGE OF USE FROM A RETAIL TO A BUILDING. SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTACLES AS WELL AS OUTDOOR LIGHTING. TOTAL SQ. FT. 1147.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62480	13041-20000-07831	725 S FIGUEROA ST #2200	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.04886	-118.26071	TENANT IMPROVEMENT TO REMOVE/ADD NON BEARING PARTITIONS; (E) CLG & LIGHTING TO REMAIN; REWORK NEW GYPBOARD CEILING IN LOBBY ON 22ND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62481	09041-20005-24367	3327 E SABINA ST Bldg B	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			11/22/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 6 Revision to approved plans for New Apartment Complex w/ multiple buildings (Bldg B) 2of 2 Building. Changes includes removing disconnect switch between generator/ATS and revised panel schedules to match as-built conditions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62482	10041-20000-01671	16585 N NICKLAUS DR PED	91342	7	228B137   192	2582001015	(T)(Q)RD3-1, A1-1, [Q]A1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM			PC Approved	02/01/2010 12:00:00 AM				Revision to meter pedestal manufacturer on approved plans with PCIS # 09041-20000-11023 (Site lighting. Outdoor Title 24 only.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62483	18041-10000-26901	8500 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	06/26/2021 12:00:00 AM	ADDRESS	34.22485	-118.50045	PERMIT IS $ 0 PERMIT FEE DUE TO ASSEMBLY BILL 1414 PV2.. FEED-IN TARIFF CARPORTS MOUNTED SYSTEM ; DIVIDED INTO TWO PV OUTPUTS EACH CONSISTING OF 3 STRINGS ( 108 LG395N2W SOLAREDGE MODULES, 54 SOLAREDGE P800 OPTIMIZERS ) INPUTS TO EACH OF 36 SOLAREDGE SE33.3KUS INVERTERS. INVERTERS OUTPUT TO 2 X ( 7 EA 250 SUBPANELS ). THE 480V/277V OF EACH OF THE  2 EA PV OUTPUTS ARE STEPPED UP TO 34.KV .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62484	16041-10000-20448	238 E 71ST ST	90003	9	102B205   722	6011007008	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	33.97533	-118.2704	PV1, rooftop solar installation, 3.6 kW   (18) KU2656ZPA    (1) PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62485	18041-30000-43479	2029 S CENTURY PARK EAST 13TH FLOOR	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	PLAN CHEK FOR T24 ONLY FOR TENANT IMPROVEMENT ; RENOVATION OF A PUBLIC ELEVATOR LOBBY ON 13TH FL. NEW LIGHTS WILL CONNECT TO EXISTING BRANCH CIRCUIT SERVING THE AREA. TOTAL AREA: 295 SQ.FT(B# 18016-10000-25400)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62486	12041-10000-29732	650 S HILL ST BASEMENT-650-EX	90014	14	129A211   215	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	34.04623	-118.25392	CRA. T24. REPLACE EXISTING LIGHTS. HIRISE. NO EMERGENCY LIGHTING PER APPLICANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62487	15041-10000-14928	700 S FLOWER ST STE-660	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Expired	06/13/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLAN CHECK FOR ENERGY ONLY FOR TI OFFICE BUILDING ON THE 6TH FLOOR. SCOPE OF WORK 1380 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62488	10041-10000-01852	843 S LOS ANGELES ST #501	90014	14	126A211    15	5145014003	M2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	02/03/2010 12:00:00 AM		Permit Finaled	04/13/2010 12:00:00 AM	ADDRESS	34.04128	-118.25358	plan check T-24 energy for general/emergency lighting. retail store #501	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62489	19041-20000-04776	11933 N SIERRA LANE	91326	12	216B121   248	2872004018	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2019 12:00:00 AM	02/08/2019 12:00:00 AM		Issued	02/08/2019 12:00:00 AM	ADDRESS	34.28914	-118.55133	pv1install roof mounted pv system sized 13.0 KW interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62490	14041-10000-14768	830 S FLOWER ST	90017	14	129A209   267	5144020***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.04641	-118.26064	T.I. To medical center.  Plan check for power and lighting total area = 11661 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62491	13041-10000-01651	11886 W ELDRIDGE AVE	91342	7	216B169    37	2531034008	(T)R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.28556	-118.39051	PV1 ROOF MOUNTED MICROINVETER SOLAR INSTALLATION ON STANDARD PLAN. TWO STORY HOUSE. SYSTEM SIZE IS 3.672 KW. [MODULES: REC # REC245PE |||| INVERTERS: ENPHASE  # M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62492	16041-10000-35032	1311 W 1ST ST	90026	1	133-5A209  85	5160015900	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Closed	01/27/2017 12:00:00 AM	ADDRESS	34.06139	-118.25805	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.275KWdc / 3.75KWac.(15)SOLARWORLD SW285(15)ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62493	13041-10000-22316	15651 W RAYEN ST	91343	12	195B141   333	2672009034	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.23203	-118.47366	FOPV1 12.99KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-5000-OUTD-US and PVI-6000-OUTD-US] [( 53) MOD: yingli {YL245-29b}](((APPLICATION HAS BEEN WITHDRAWN))))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62494	13041-10000-09761	722 N EAST KENSINGTON ROAD	90026	1	136-5A211 162	5405023013	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Apartment			04/16/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.06884	-118.25159	PV2 MULTI FAMILY DWELLING. PHOTOVOLTAIC SYSTEM FOR HOUSE. PART OF SERIES OF 3 SUBMITTALS. THIS IS APPLICATION 1 OF 3. TOTAL SYSTEM SIZE 3.92 KW. NONSTANDARD PLAN. TRANSFORMERLESS INVERTER. SINGLE STRING. POWER OPTIMIZERS.(((LOCATION IN METHANE ZONE, TRENCH WORK TO BE DONE. 2' DEEP)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62495	15041-10001-01918	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM			PC Approved	06/23/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	Expedite per applicant request(((Installation of new roof mounted solar PV array.  Total system size = 100 kWac.  452 Total modules (Sunpreme SNPM GxB 280) with 5 inverters (SMA STP 20000 TL-US)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62496	16041-20000-31750	1750 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   333	5021032032	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Apartment			09/07/2016 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Closed	05/05/2021 12:00:00 AM	ADDRESS	34.01068	-118.31073	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR LIGHTING. 63000SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62497	12041-10000-26153	2313-2323 S HOOVER ST	90007	1	124-5A201 259	5055020001	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	PIN	34.03463486	-118.28420825	PLAN CHECK POWER AND ENERGY FOR 6 FUTURE TENANT SPACES IN EXISTING BUILDING. NEW ELECTRICAL SYSTEM WITH 800A SERVICE. SITE LOCATED IN METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62498	13041-10000-19839	505 S VIRGIL AVE SUITE 107	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	07/25/2013 12:00:00 AM	ADDRESS	34.0649	-118.28724	TI for pharmacy.  Newly connected load less than 400A, title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62499	16041-10002-16012	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			02/20/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	PIN	34.04222127	-118.45848597	"PC FOR REVISION TO APPROVED SET UNDER DELTA 3. SCOPE INCLUDES RESIZE OF GROUNDING CONDUCTORS EGC ON ""MSA"" AS MARKED. THIS IS PLAN CHECK ONLY!  PC FOR LOST SET OF PLANS WITH ADDITIONAL ON SITE REVISIONS UNDER DELTA 2.NEW REVISIONS INCLUDES NEW CIRCUITS AND ADDITIONAL EQUIPMENT PANEL AND TRANSFORMER.NEW MIXED USED APARTMENT BUILDING 147 UNIT 5 STORIE .PLAN CHECK FOR POWER AND ENERGY. 12 TYPICAL UNITS, 6 LOFTS AND 3 LIVEWORK UNITS. WITH TOTAL AREA OF 1927884 SQFT. NOTE FIRE ALARM VARIANCE IS FILLED TOGETHER. BUILDING APPLICATION NUMBER 14041-10000-03747."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62500	13041-10000-10330	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	34.05436	-118.25543	PLAN CHECK FOR TITLE 24 PART 6 ENERGY CODE AND EMERGENCY LIGHTING ON A COMMERCIAL HIGH RISE (GIFT SHOP ON GROUND LEVEL) TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62501	15041-20001-40820	1926 N ALVARADO ST	90039	13	144A209   157	5420004018	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	ADDRESS	34.08901	-118.25632	Expedite per applicant request(((((Plan check for PV roof monted system. System size: 3.8kW with 19 modules and 1 inverter(3.8kW))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62502	15041-10001-21475	5637 N COSTELLO AVE	91401	2	174B153   641	2246031004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2015 12:00:00 AM			PC Approved	07/13/2015 12:00:00 AM	ADDRESS	34.17322	-118.43793	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW (3+3). Ungrounded system. (20) 327W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62503	18041-20000-10295	8854 S MAIN ST	90003	8	096A205   291	6041005033	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	33.95626	-118.27369	Plan check for power and energy. Project site is an existing commercial building. Project scope is an addition and a change of use from retail to laundromat. Work includes a 1,600-amp service and a total lighting area of 6,922 sq. ft.Note: Building application has been generated under 18014-20000-01101	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62504	15041-10000-10178	800 S FIGUEROA ST 10th Flr	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Issued	07/28/2015 12:00:00 AM	ADDRESS	34.04771	-118.26116	Energy plan check for a commercial T.I on the 10th floor of a high rise building. Scope includes installing new light for corridor, restroom and lobby area . Total area covers 1319-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62505	18041-10000-26011	2828 N NEWELL ST Suite #3	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.10192	-118.24324	TENANT IMPROVEMENT OF AN EXISTING OFFICE AREA & CONFERENCE ROOM IN SUITE #3. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62506	18041-20000-12534	17516 W HIAWATHA ST	91344	12	204B129    72	2733013038	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.25922	-118.51612	pv1install roof mounted pv system sized 12.6kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62507	15041-10000-19561	2139 S LOS ANGELES ST	90011	9	121-5A207  86	5127028013	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.0275	-118.26576	TI TO AN EXISTING SINGLE STORY COMMECIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  BUILDING SUBMITTAL BEFORE JULY 1, 2015.  2008 ENERGY STANDARDS APPLY. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62508	17041-10000-18134	1360 E 17TH ST	90021	14	120A211    72	5129001046	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.02435	-118.24774	PC for T24 only for removal of outdoor metal halide fixture and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62509	19041-10001-01662	10346 N LAUREL CANYON BLVD	91331	7	204B157   221	2646004020	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM			PC Approved	03/21/2019 12:00:00 AM	ADDRESS	34.25838	-118.43143	"DELTA ""1"" CHANGES TO APPROVED PLANS FOR T-243 ENERGY ONLY. CHANGING 2X4 TO 2X2.<<<NEW RETAIL STORE. FULL PLAN CHECK POWER AND ENERGY. NEW 600 AMP SEVICE. 3850 SQR FT. BULDING PERMIT: 18016-20000-41315>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62510	16041-20000-28698	11046 W MAGNOLIA BLVD	91601	2	171B173   609	2353006014	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM			PC Approved	08/12/2016 12:00:00 AM	ADDRESS	34.16478	-118.3721	RECHECK FOR LOST SET OF PLANS.  THIS IS PLAN CHECK ONLY.PERMIT PAID UNDER APPLICATION NUMBER 16041-20000-17268Plan check for Title 24 only in exising space, change of use from auto body shop to New Bar Lounge. Total area: 1,278 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62511	13041-10001-33148	10161 N LANGMUIR AVE	91040	7	204B193  1064	2559034044	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/07/2013 12:00:00 AM	ADDRESS	34.25399	-118.30881	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62512	15041-10000-34049	1800 S AVENUE OF THE STARS 6TH FLR-elev-lobby	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	Title 24 plan check only.  Total area = 355 sq. ft.    T.I. to the 6th floor elevator lobby. Scope includes new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62513	14041-20000-08706	21255 W BURBANK BLVD 5th Fl	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Info Complete	05/08/2014 12:00:00 AM	ADDRESS	34.17432	-118.59446	T.I. to existing high rise building on the 5th floor.  Install subpanels, transformers, and lighting.  Plan check for power and energy.Note: The previous approved plans and addition page will be submitted by the applicant before the plans get assigned.  Plan check fee calculated base on the number of devices provided by the applicant.   Final fee needs to verify.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62514	11041-10000-19089	735 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM	04/11/2012 12:00:00 AM		Permit Finaled	10/03/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	TENANT IMPROVEMENTS FOR TARGET STORE. Plan check power, T24 and emergency lighting.  Existing service equipment.  Ref.#11042-10000-15835.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62515	16041-10000-02401	6069 E DELPHI ST	90042	14	157-5A229 351	5486006005	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.12421	-118.18787	PV1, INSTALL 5.04 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FASMILY 2-STORY HOUSE.(18) MODULES: HYUNDAI HIS-S280RG(1) INVERTER: FRONIUS PRIMO 5.01-1 240	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62516	16041-10000-40582	1112 W PASEO DEL MAR	90731	15	006B193   382	7469025007	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	33.71274	-118.30467	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(34)MODULES-SOLARCITY#SC265(1)INVERTER-FRONIUS# PRIMO 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62517	13041-20000-17418	20701 W KESWICK ST PV-1	91306	3	189B109  1048	2108035001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.2105	-118.58445	PV-1. Solaredge with power optimizers. Transformerless. One 3.8Kw Inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62518	10041-20000-21819	9540 N DE SOTO AVE	91311	12	201B109   302	2748023042	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	11/04/2010 12:00:00 AM	ADDRESS	34.24423	-118.58835	Plan check T24 general/emergency lighting for manufacturing space TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62519	17041-20000-20932	5946 N FAIRHAVEN AVE	91367	3	177B089   837	2046004***	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.17715	-118.65387	PV1.  Install 6.55 kW roof mounted grid tied PV system.  (19) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62520	18041-10000-43522	1421 N EDGEMONT ST	90027	13	147B197   810	5543020024	RD1.5-1XL	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	34.09733	-118.29631	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62521	18041-10000-08147	1133 S FLOWER ST Tower 2-42-stories	90015	14	127-5A207 344	5138015045	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Expired	02/02/2024 12:00:00 AM	ADDRESS	34.0423	-118.2651	PC for new FA system for Tower 2 of Oceanwide Plaza.  This fire alarm system is networking with fire alarm systems in Tower 1, Tower 3, and Retail Podium.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62522	19041-10000-21603	8105 N CANOGA AVE	91304	3	189B105    90	2110020002	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Issued	06/07/2019 12:00:00 AM	ADDRESS	34.21715	-118.59772	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62523	11041-20000-07924	8840 N CORBIN AVE	91324	12	195B117    64	2783025092	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM			Corrections Issued	04/20/2011 12:00:00 AM	ADDRESS	34.23069	-118.56211	WORK BEING DONE DOES NOT INCLUDE LIGHTING.  THE EXISTING LIGHTING IS TO REMAIN.  NO NEED FOR TITLE 24 PLAN CHECK.  <<<<<<<<<<<<EXISTING RETAIL.  RELOCATING LIGHT AND REPLACING LIGHTING FIXTURES. TITLE 24 PLAN CHECK ONLY.>>>>>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62524	15041-20000-05427	10040 N NITA AVE	91311	12	204B101   494	2745007053	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.25294	-118.61357	Plan check for a PV1 roof-mounted PV system. System size is 11.25 kWac. System consists of (45) modules, (45) micro-inverters and (1) 100-amp rated PV distribution panel. The main service panel is being upgraded to a 225-amp rated panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62525	16041-10000-05143	658 E VENICE BLVD 2ND FLR	90291	11	108B145  1620	4237002006	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	33.98963	-118.46093	TI TO AN EXISTING COMMERCIAL BUILDING (SECOND FLOOR).  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.TOTAL SQUARE FOOTAGE 11350BUILDING APPLICATION NUMBER 15016-10000-11598	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62526	11041-20000-18654	15350 W SHERMAN WAY Ste 100	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM			PC Approved	09/01/2011 12:00:00 AM	ADDRESS	34.20099	-118.46808	T.I.  Remodel of the light fixtures in Suite 100.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62527	19041-20002-28479	10415 W CUMPSTON ST	91601	2	174B177   823	2417010012	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM			PC Approved	10/09/2019 12:00:00 AM	ADDRESS	34.17042	-118.35761	09-19-2019 Changes to an approved set of plan, Changes include relocate equipment PV system and removal of AC disconnect. All Change has been clouded. Plan check onlyFees $0.00 due to California Senate Bill 1222  and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62528	10041-20000-18360	12400 W WILSHIRE BLVD 7th Floor	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM			PC Info Complete	09/16/2010 12:00:00 AM	ADDRESS	34.04157	-118.47031	T.I. in an existing high rise building in elavator lobby, conference, library, break, storage areas.  Install general/emergency lighting.  EPC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62529	15041-20000-01732	11032 N DEMPSEY AVE	91344	12	210B141   655	2667014019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.27089	-118.47691	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62530	14041-20000-26249	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.18088	-118.48309	PC FOR POWER ONLY. REBUILD 4160V BUSSING. NEW MOTOR CONTROLLERS. ALL LOADS EXISTING. NO CHANGE IN MOTOR JUST BUSSING AND CONTROLLERS. REPLACE RATING OF EQUIPMENT LIKE FOR LIKE. RECHECK FOR 5KV WIRING AND RECHECK OVERLOAD PROTECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62531	10041-20000-11628	15800 W VENTURA BLVD	91436	5	168B141   643	2283009014	C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1414.00	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	01/05/2012 12:00:00 AM	ADDRESS	34.15528	-118.47771	Plan check power and energy for addition to auto sales showroom.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62532	15041-20000-03070	5235 N LANKERSHIM BLVD	91601	2	171B173   439	2350017034	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.16584	-118.37546	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NOHO FRESH. INDOOR AND OUTDOOR LIGHTING. 902 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62533	16041-10000-06178	3060 W OLYMPIC BLVD	90006	10	129B193   469	5080030019	C2-1, R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			02/22/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.05239	-118.30229	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 7 STORY, 226 UNIT MIXED USE APARTMENT BUILDING; 1 LEVEL BELOW, 2 LEVEL ABOVE PARKING GARAGE AND 5 LEVELS OF TYPE 3 RESIDENTIAL; NEW 4000A 277/480 3 PHASE, 4W SERVICE. TOTAL AFFECTED AREA IS 161,199 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62534	14041-10000-18095	1505 N AVENUE 56	90042	14	157-5A227 390	5485004002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM			Not Ready to Issue	07/03/2014 12:00:00 AM	ADDRESS	34.12407	-118.19658	Install roof mounted solar system on existing residential building.  Total system size = 6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62535	15041-20001-19724	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM.  FEED IN TARIF. REQUIRES CONDITIONAL APPROVAL FROM PLANNING.  SYSTEM SIZE: 700 KW.SYSTEM A: 378KW DC1221 MODULES TRINA SOLAR15 INVERTERS SOLECTRIA PVI-20TLSYSTEM B: 320 KW DC1034 MODULES TRINA SOLAR12 INVERTERS SOLECTRIA PVI-20TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62536	16041-10000-07009	5915 W BOWCROFT ST	90016	10	117B173   126	4204008064	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.01925	-118.37654	"PC FOR POWER AND ENERGY. ADDITON OF 100A TEMP GENERATOR AND 1500A NEW ONE , NEW500KVA UPS INPUT TRANSFORMER, 800A TRANSFORMER DISCONNECT, NEW 4OOA UPS, 2 NEW UPS BATTERY CABINETS, NEW 800A UPS OUTPUT PANEL, NEW75KVA PDU""S, 2 NEW CRAC AND ATS, CRV UNITS, NEW LIGTHING IN UPS ROOM. TOTAL AREA 750 SQ FT. T24 PFORMS IS NOT COMPLETE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62537	14041-20000-18405	13237 N GLADSTONE AVE	91342	7	225B157   672	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			07/08/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.31154	-118.42954	Plan check for power and energy. Change Rite Aide retail store into a 99cents retail store. Existing service to remain. All other equipment is new, including panels and air conditioning units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62538	16041-10000-40031	777 S ALAMEDA ST SUITE 100	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.03396	-118.24117	Plan check for power and TItle 24.  T.I. to first floor of existing commercial building.  First time tenant.  Total area = 16,179 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62539	14041-10000-10190	837 N KODAK DR	90026	13	142-5A201 224	5427020002	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.08408	-118.28027	Install 5.25 kW DC roof-mounted solar array on a two-story house, interconnect with  main service panel. (1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U. (21) Modules: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62540	15041-10000-08762	718 E 61ST ST	90001	9	105B205   601	6007009008	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	33.9843	-118.26231	TI 24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. ENERGY SQ FT. 17860	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62541	10041-10001-05580	701 E NEW DOCK ST	90731	15	024B209     5	7440020***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM			PC Approved	09/24/2010 12:00:00 AM	ADDRESS	33.75567	-118.25325	PLAN REVIEW OF THE BUS AMPERE RATING OF PANEL PMLA; PER PAT GILBERT'S INSTRUCTION, EXISTING INSTALLATION IS AS IS; APPLY ARTICLE 690 UP  TO PANEL PMLA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62542	19041-20000-06233	16040 W PLUMMER ST pv1	91343	12	198B141    58	2671014047	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	PIN	34.24258493	-118.48206061	pv1install roof mounted pv system sized 5KW AC interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62543	10041-20000-09734	21700 W OXNARD ST	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM	06/01/2010 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.17901	-118.60179	Replacing approximately 100 ft long 4000A buss duct with exact rating that was damaged due to water leak with exact rating and type.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62544	18041-30000-47975	3270 N CAHUENGA BLVD WEST	90068	4	159B181   594	2429009003	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.12999	-118.34908	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,414 sq. ft.Note: Building permit has been issued under 18016-20000-35900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62545	19041-20000-05931	10536 W GARWOOD PL pv1	90024	5	135B153   143	4360020014	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.06808	-118.43489	$0 permit fee due to SB1222 and AB1414pv1install roof mounted pv system sized 11.4KW AC interconnected with msp. scope of work includes (45) panasonic vbhn330 pv modules with P400 optimizers, 1 SE11400H inverter,, a new 225A load panel, and 1 SONNEN ECO 10 battery	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62546	18041-10000-45672	11647 W VENTURA BLVD	91604	2	162B169   395	2368007006	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.14086	-118.38606	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62547	16041-20000-23921	14358 W MAGNOLIA BLVD 1-95	91423	4	171A151    50	2248009025	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			Reviewed by Supervisor	07/19/2016 12:00:00 AM	ADDRESS	34.16469	-118.44621	PV2.  Install 13.95 kW DC roof-mounted PV system.  (45) modules with (2) 6kW transformerless central inverters.  System 2 of 2 for this parcel.Zoning clearance for the property can be found under 16041-20000-23917	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62548	13041-10000-30132	10458 N DES MOINES AVE	91326	12	207B117   448	2728007009	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.26049	-118.55459	PV1, Install 9 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 36 modules Fronius IG Plus V 7.5.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62549	19041-10000-21785	3010 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/07/2019 12:00:00 AM			PC Info Complete	06/19/2019 12:00:00 AM	ADDRESS	34.02695	-118.42808	PC for T24 only, of an interior remodel of a CVS pharamacy. Scope of work includes new lighitng and circuits, and new equipment, total affected area is 905 sqft. Note: Plans are missing stamps and signatureB#19016-10000-17203	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62550	14041-20000-32312	5815 W SUNSET BLVD 304, 305	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.09822	-118.31613	Plan check for energy only. TI on 3rd floor of existing office building. First-time tenant build-out - new office space. New receptacles and lighting (incl. emergency). 1,964sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62551	16041-10001-09520	825 S HILL ST	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			12/28/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Closed	01/14/2021 12:00:00 AM	ADDRESS	34.04392	-118.25657	CHANGES TO APPROVED SET OF PLAN. SCOPE INCLUDES UP-SIZING MAN HOIST FROM 52FLA TO 113FLA, OCPDS FROM 100A TO 150, CONDUCTOR SIZES, AND INCREASE LOAD CALCULATIONS. (NO NEW LOADS ADDED). ORIGINAL PLAN CHECK APPLICATION 16041-10000-09520Temp Power for a  Proposed  49 story high rise with 490 APARTMENT Units. 1000amp Service with connected load including a fire pump, crane, man lifts and 3 transformers.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62552	14041-10000-11997	1520 W 28TH ST	90007	8	123B197  1577	5054034004	R2-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.02942	-118.29515	Install roof-mounted solar array, interconnect with main panel.System size = 2.295 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62553	12041-10000-07977	616 N NIMES ROAD	90077	5	144B153   893	4362025006	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	09/18/2013 12:00:00 AM	ADDRESS	34.08726	-118.43754	Plan check for remodel of existing single family dwelling and addition of recreation room with 800 Amps service. Garages and recreation room are attached to main house.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62554	19041-20000-06761	10847 N CARTWRIGHT DR	91311	12	207B113   337	2708029015	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2019 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.26794	-118.56661	PV1.  Install 6.03 kW roof mounted grid tied PV system.  (18) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62555	17041-10000-41008	1525 N HOBART BLVD	90027	13	147A195    46	5544019014	R3-1XL	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			12/13/2017 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	04/11/2024 12:00:00 AM	ADDRESS	34.09893	-118.30586	New 4 story apartment house with 21 units. 1000A 120/208 V 3ph, 4W service, (3) 100A housepanels, (21) unit panels, and motor loads. B# 17010-30000-02833	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62556	10041-20000-23543	2802 W 8TH ST	90005	1	132A201    60	5077022002	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			11/24/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	12/06/2011 12:00:00 AM	ADDRESS	34.0576	-118.28694	renovate and service upgrade to 400 A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62557	15041-10001-06990	1965 N MOUNT OLYMPUS DR	90046	4	151-5A175 297	5569035007	RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM			PC Approved	04/02/2015 12:00:00 AM	ADDRESS	34.1075	-118.36601	Expedited plan check fees per applicant request.  (((PV1.  Install 15.696 kW roof-mounted, utility-interactive PV system.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62558	14041-10000-07463	4321 N MATILIJA AVE	91423	4	165B153   415	2271016***	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			03/20/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Expired	09/14/2016 12:00:00 AM	ADDRESS	34.14936	-118.43417	PV2. ROOFMOUNTED SOLAR SYSTEM ON UNIT 18 OF CONDOMINIUMS, NON STANDARD MICROINVERTER PLANS. SYSTEM SIZE: 3.71 KW.(14) SOLARWORLD 265W(14) ENPHASE M215 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62559	16041-10000-45763	5203 N LANKERSHIM BLVD	91601	2	171B173   588	2350017058	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			Corrections Issued	12/30/2016 12:00:00 AM	ADDRESS	34.16507	-118.37498	T-24, PC FOR ENERGY ONLY. RENOVATION TO (E) RESTAURANT. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3405 SQ. FT. B#16014-10000-06127	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62560	16041-10000-26887	3330 W BEVERLY BLVD 1-40	90004	13	138A201   136	5501018001	C2-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.07311	-118.28539	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR 40 UNIT APARTMENT BUILDING WITH 144 FIRE ALARM DEVICES AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62561	16041-10000-39486	2105 E CESAR E CHAVEZ AVE	90033	14	129A223   105	5175014003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM			Corrections Issued	11/08/2016 12:00:00 AM	ADDRESS	34.04846	-118.21113	PC for energy only. TI change of use from retail to restaurant. Adding new lighting and power. Total sqft = 783	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62562	17041-20000-16707	24032 W ARMINTA ST	91304	12	189B089   245	2020031042	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Expired	04/21/2024 12:00:00 AM	ADDRESS	34.21347	-118.65094	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (32) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62563	13041-20001-23682	12746 W KLING ST	91604	2	168B161   626	2362022004	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.15569	-118.41113	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 16 KW AC USING 3 CENTRAL INVERTERS, TRANSFORMERLESS. NONSTANDARD PLAN. TOTAL OF 47 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62564	13041-10000-03925	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.0344	-118.45642	PERMIT TO BE ISSUED BY PC ONLYPC FOR ENERGY ONLY. TI TO EXISTING BLDG (RESTROOMS AND OUTDOOR LIGHTING). LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62565	12041-20001-06716	7726 N GLORIA AVE	91406	6	189B141   256	2206010026	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM			PC Approved	01/31/2013 12:00:00 AM	ADDRESS	34.21103	-118.47917	Changes to approved set of plans. Title-24 energy only. Emergency lighting to remain as is. Pet Clinic t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62566	10041-10000-19869	10716 1/2 S AVALON BLVD	90002	8	090A207   436	6051030003	RD2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM			PC Approved	10/06/2010 12:00:00 AM	ADDRESS	33.93874	-118.26499	TI IN AN EXISTING RETAIL. PLAN CHECK FOR T24. (PERMIT WAS PULLED #10041-10000-17012)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62567	15041-10000-43369	606 E VENICE BLVD bldg A	90291	11	108B145  1741	4237002007	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.98922	-118.46166	Full PC to existing commercial building (building A). Newly connected load is greater than 400 A. Total Sqft = 22913TENANT IMPROVEMENT TO  AN EXISTING COMMERCIAL BUILDING FOR SOFTWARE LIGHT MANUFACTURING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62568	15041-10000-13018	6171 W CENTURY BLVD 1ST FL &-BSMNT	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	IN EXISTING ,EMPTY OFFICE SPACE ON BSMNT AND 1ST FLOORS, INSTALLING SOME LUMINAIRES AND POWER UN THE CORRIDOS, AND ELEVATOR LOBBIES FOR PROSPECTIVE TENAT.PLAN CHK IS FOR TITLE 24 AND 2  EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62569	19041-20000-22693	9759 N ABREGO CT LOT 15	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.24756	-118.45069	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62570	19041-20000-29008	555 W 5TH ST 4TH FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	04/20/2020 12:00:00 AM		Permit Finaled	10/15/2020 12:00:00 AM	ADDRESS	34.05016	-118.25369	Power and lighting for TI to (E) commercial highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62571	16041-10000-07013	131 E 50TH ST	90011	9	111A205   273	5109004013	RD2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	33.99755	-118.27331	New Fire alarm system on (N) 1 story middle school build. (1) panel, (1) comm. panel (92) devices. (Phase 1 of 2)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62572	19041-10000-23781	6333 W 3RD ST 706	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.07157	-118.36014	"NEW METHANE DETECTION SYSTEM (LEVEL 2) IN ""THE TAVERN"" (EXISTING RESTAURANT), UNIT #706 IN FARMERS MARKET . BULDING PERMIT: 18016-30000-01543"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62573	19041-10000-11366	24901 S FRAMPTON AVE	90710	15	039B197   142	7439027903	OS-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	33.79836	-118.29927	Remove HID fixtures and replace with new LED fixtures (Indoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62574	16041-20001-39962	23130 W VICTORY BLVD	91367	3	180B093   907	2039012020	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2016 12:00:00 AM			PC Approved	11/19/2016 12:00:00 AM	ADDRESS	34.18623	-118.631	PV1.  Install 4.52 kW AC addition to an (E) 8.71 kW DC system.  (15) AC modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62575	19041-10000-15903	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			Verifications in Progress	10/30/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	Full plan check for (core and shell) Building A and B. (6) Exisiting service size but with new equipment/ SWBD. Building A1 2 service: 5000A and 2500A, 480/277V; Building A2: 6000A, 480/277VBuilding B: 6000A, 2000A, and 800A 480/277VTotal area approx: 885,111 sq.ft<<B# 18016-10000-23767: Tenant improvement to existing office/showroom and retail bldg and partial window replace, removal of exist glass roof in interior concourse, removal of existing curtain wall on bridges bet bldg A&B as well as removal of escalators on these bridges, alteration of existing plaza bldg, new hardscape and landscape in plaza, new and modernized elevators and new bldg infrastructure; no change of use under this application>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62576	16041-30000-45298	658 E 89TH ST	90002	9	096A207   212	6042009021	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	33.95551	-118.26317	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62577	19041-20000-12297	11644 N HILLTOP LANE	91342	7	213B169  1017	2530001018	(T)RU-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.28253	-118.38377	PV1.  Install 4.02 kW roof mounted grid tied PV system. (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62578	09041-20001-22390	320 S BRISTOL AVE	90049	11	129B137   141	4405023005	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2011 12:00:00 AM			PC Info Complete	04/18/2011 12:00:00 AM	ADDRESS	34.05248	-118.48669	PLAN CHECK FOR REVISION TO APPROVED PLANS. INCREASE SERVICE TO 1000A , NEW EQUIPMENT, AND CKTS INSTALLED.  SUPPLEMENTAL PERMIT MAY OR MAY NOT BE NEEDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62579	19041-10000-53840	13204 S ESTRELLA AVE	90248	15	078B201    18	6132003014	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.91354	-118.28549	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR/OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62580	17041-30000-31258	1553 S ARMACOST AVE 1-6	90025	11	126B145   704	4263034017	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.04047	-118.45928	Plan check for New Fire alarm system for new 4 story 8 units appartment. Total devices: 71 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62581	11041-10000-10799	20721 W SUPERIOR ST	91311	12	201B109   203	2748004049	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	05/25/2011 12:00:00 AM		Permit Finaled	06/03/2011 12:00:00 AM	ADDRESS	34.24646	-118.5849	NEW FIRE ALARM FOR SINGLE STORY BUILDING.  I FIRE ALARM PANEL.  PLAN CHECK AT THE COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62582	18041-10000-20769	1039 S LA CIENEGA BLVD	90035	5	132B173   489	4332030025	C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.05828	-118.37637	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62583	09041-20002-18384	13339 W LOUVRE ST	91331	7	210B157   317	2535003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM	07/14/2010 12:00:00 AM		Permit Finaled	07/20/2010 12:00:00 AM	ADDRESS	34.27146	-118.42398	Plan check for power (first time tenant) to install equipment for soil vapor extraction and soil clean up unit. Core and Shell electrical system plans was finaled under #08041-10000-22875. Modification from methane zone to methane buffer zone was filed under seperate application. Permit for additional (5) ckts and panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62584	17041-10000-39983	10880 W WILSHIRE BLVD #1000	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.05885	-118.44283	Plan check for Title 24 only in existing high rise office T.I. Total area: 6,550 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62585	13041-20000-36179	2489 W WASHINGTON BLVD	90019	10	126B189   886	5073024002	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM			Reviewed by Supervisor	01/06/2014 12:00:00 AM	PIN	34.04024142	-118.31746554	New 600 amp service (overhead) in a Methane Zone, in an existing mixed-use building.  All lighting is existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62586	14041-20000-20679	19301 S PACIFIC GATEWAY DR	90502	15	057B197     4	7351031007	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	33.85591	-118.29547	Plan check for energy only on a new office with 990 SF inside a warehouse building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62587	19041-10000-44482	3730 W 27TH ST	90018	10	123B189   891	5051016012	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.031	-118.32517	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62588	12041-10000-07216	12320 N SAN FERNANDO ROAD	91342	3	171B125    79	2160008038	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2012 12:00:00 AM			Reviewed by Supervisor	04/16/2012 12:00:00 AM	ADDRESS	34.29476	-118.45246	New rooftop photovoltaic system for an existing single family residence.   4.8kw system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62589	13041-10001-31282	22100 W INDEPENDENCIA ST	91364	3	168B101  1005	2076022060	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.15268	-118.60797	][][EXPEDITED PER APPLICANT REQUEST ][][][PV1, ROOF-MOUNTED SOLAR INSTALLATION INTERCONNECTED TO (E) 200 MAIN ON NON-STANDARD PLAN IN SINGLE STORY HOUSE. SYSTEM SIZE IS 5.4 kW DC AND IS XFORMERLESS, WITH (20) MODULES (SOLARWORD SW270) AND (1) INVERTER ( POWER-ONE PVI-5000-OUTD-US)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62590	12041-10000-04146	6221 W WILSHIRE BLVD #102	90048	5	135B177   486	5510027037		Central				2147.00	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	34.06345	-118.3639	CONVERSION OF OFFICE TO MEDICAL OFFICE SUITE #102 TENANT IMPROVEMENT. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62591	13041-10000-32962	14738 W BLACKHAWK ST	91345	7	204B149   186	2648010007	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			No Progress	03/13/2014 12:00:00 AM	ADDRESS	34.25803	-118.45366	PV1, Install  4.5 kw DC roof-mounted solar array, interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 18 modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62592	12041-10000-04002	9800 N LAUREL CANYON BLVD	91331	7	201B157   311	2622017021	P-1VL	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			PC Approved	02/22/2012 12:00:00 AM	ADDRESS	34.24825	-118.42066	alterations in el pollo restaurantplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62593	14041-20001-14992	15701 W TUBA ST	91343	12	204B141   425	2661016009	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.25655	-118.4742	Fee for expedite only.*****New roof mounted PV system with Optimizers and transformerless inverters.  Total system size 7.4KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62594	14041-20001-33469	4233 N SHADYGLADE AVE	91604	2	165B165   817	2367007019	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.14776	-118.40203	expedite per customer request.pv1install roof mounred pv system sized 7.6kw interconnected with msp.(31) trina solar tsm-255 modules(1) solaredge se7600 inverter(31) power optimizers p300	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62595	12041-10000-30316	3627 S HOLDREGE AVE	90016	10	117B173    72	4204008018	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM	12/17/2012 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.02046	-118.37825	PLAN CHECK FOR FIRE ALARM. INSTALLATION OF FIRE ALARM FOR SPRINKLER SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62596	16041-10000-21424	1817 W 71ST ST	90047	8	102B193  1112	6016026007	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Expired	07/23/2018 12:00:00 AM	ADDRESS	33.97548	-118.30951	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(8)SOLARCITY STANDARD 265KW(1)INVERTER-ABB# PVI-3.0-OUTD-S-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62597	17041-10001-28920	2020 N MANDEVILLE CANYON ROAD	90049	11	138B137   462	4426023017	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM			Reviewed by Supervisor	01/07/2019 12:00:00 AM	ADDRESS	34.07235	-118.49511	Installing 2 wall mounted tesla energy storage system at 5 kVA each. portion of fee paid online. 17041-90000-28920	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62598	18041-10000-22218	3435 W WILSHIRE BLVD 14th floor	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM			Reviewed by Supervisor	06/22/2018 12:00:00 AM	ADDRESS	34.06194	-118.29866	TENANT IMPROVEMENT ON THE 14TH FLOOR OF AN OFFICE BULDING. NEW CONNECTED LOAD IS MORE THAN 400AMP. FULL PLAN CHECK FOR POWER AND 19,680 SQR FT ENERGY. BUILDING PERMIT: 18016-10000-08827PARTIAL ELECTRICAL PERMIT WAS ISSUED UNDER 18041-90000-18163	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62599	16041-20000-02273	6600 N TOPANGA CANYON BLVD #2048	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Adding new track lights to existing lighting system. Total area: 178 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62600	18041-20000-46882	13273 W SEVILLANA WAY LOT 7	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.31511	-118.42278	Plan check for PV roof mounted system,system size: 1.68KW with 7 PV Modules and7 microinverters. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62601	14041-20003-03103	12600 W VOSE ST	91605	2	183B161   418	2324023018	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	03/18/2014 12:00:00 AM	ADDRESS	34.19827	-118.40747	(((3/18/2014- Changes made to approved set of plans. Changing the number of J-boxes used on the roof. additional permits is not required.)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62602	19041-10000-31510	5181 W ADAMS BLVD	90016	10	123B177   915	5049016048	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	11/23/2020 12:00:00 AM		Permit Finaled	06/01/2023 12:00:00 AM	ADDRESS	34.03267	-118.35464	FULL PC FOR A NEW 5000A SERVICE THAT FEEDS A HOUSE DISTRIBUTION BOARD RATED AT 2000A 120/208, AND A RETAIL DISTRIBUTION BOARD RATED AT 5000A BUST 120/208. THE 5000A BUS THEN SUBFEEDS FOUR MULTI METERING SECTIONS, ALL MULTI METERING SECTIONS ARE RATED AT 800A. TOTAL AFFECTED AREA IS 114,721 SFQT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62603	19041-20000-41123	5505 N CALHOUN AVE	91401	4	174B153  1042	2245023013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.17036	-118.44231	PV roof mounted system, PV system size: 15.12KW with 42 PV Modules and 2 inverter(7.6KW), sub-panel and main panel PV ready.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62604	15041-10001-29065	3527 S 10TH AVE	90018	10	120B185  1247	5044009035	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM			PC Approved	03/25/2016 12:00:00 AM	ADDRESS	34.02338	-118.32846	PC ONLY FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac. (8)MODULES-SOLARCITY SC-265(1)INVERTER-ABB#PVI-3.0-OUTD-S-US-ZNOTE: CLEARANCE AND PERMIT PULLED UNDER PCIS#15041-90000-29065((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62605	16041-10001-19933	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	12/02/2016 Changes to an approved set of plans. Changes include layout of floor plan and number of lighting fixtures decrease. Changes apply to ADD-018 only((((((((PC FOR ENERGY FOR FACILITY IMPROVEMENT FOR TERMINAL 3 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUSING OPERATION, OFFICE RENOVATION, AND IMPROVED FINISHES AND MILLWORKTHE APPLICATION 16041-10000-11825 IS RELATED TO CONNECTED LOAD OTHER THAN THE SCOPE OF THE WORK FOR THIS PROJECT.BUILDING APPLICATION IS 16016-1000-11866. TOTAL AREA 4991 SQ FT.))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62606	12041-20000-14472	12500 N WOODLEY AVE	91344	12	219B137    40	2605004009	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.29864	-118.49597	Roof mounted Photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62607	13041-10000-26586	9140 S WESTERN AVE	90047	8	094-5A193 160	6037028044	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	33.95333	-118.30881	Remove HID light fixtures and install new fluorescent fixtures.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62608	17041-10001-20429	1600 N CAMPUS ROAD HINCHLIFFE-HALL	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.12626	-118.21412	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF NEW AREA TO T24 PLAN CHECK AND LIGHTING.  ORIGINAL PERMIT #:17041-10000-20429T-24, PC FOR ENERGY ONLY. TI FOR A CONFERENCE ROOM WITHIN AN EXISTING SCHOOL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS  1417 SQ. FT.  B#17016-10000-16354	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62609	14041-20000-20586	20242 W ELKWOOD ST	91306	3	189B113  1018	2107022071	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.21222	-118.57445	pv1install roof mounted pv system sized 6.48kw interconnected with main service panel.(28) lg solar lg265s1c modules(28) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62610	18041-20002-02157	17647 W KITTRIDGE ST	91406	6	180B129   432	2229017014	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	34.19036	-118.51801	06/19/2018 Changes to an approved set of plans. All changes have been clouded. Equipment has been relocated as noted. *****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (12) modules, (1) load center, and (1) Tesla PowerWall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62611	17041-20001-02244	3230 S OVERLAND AVE	90034	5	120B161    14	4314025043	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			01/24/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.02892	-118.4146	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 38 kWac and consists of (5) inverters, (158) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62612	13041-20000-00808	7048 N SAUSALITO AVE	91307	3	183B101   848	2024041018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2013 12:00:00 AM	02/08/2013 12:00:00 AM		Permit Finaled	02/21/2013 12:00:00 AM	ADDRESS	34.19906	-118.61612	New 7.8kw PV system for an existing single family residence.  Rootfop mounted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62613	13041-10000-13905	4075 S FIGUEROA ST	90037	9	115-5A201 229	5019023030	C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Apartment			05/29/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	34.0098	-118.28296	tITLE 24 AND EMERGENCY LIGHTING, TOOK OLD LIGHTS AND  REPLACED WITH NEW LIGHTS, THIS IS COMMON AREA TO APARTMENT BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62614	16041-30000-28507	287 S 26TH ST	90402	11	129B137   580	4264001012	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.04691	-118.48999	Plan check for Title 24 only in existing building T.I. Bank. Total area: 3,025 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62615	15041-20000-14421	19333 W SANTA RITA ST	91356	3	171B117    96	2163004011	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM			Reviewed by Supervisor	05/28/2015 12:00:00 AM	ADDRESS	34.16778	-118.5546	PV1Install photovoltaic roofing shingles on a SFD. Interconnect with a 200A MSP.System size: 4kW. Ungrounded system. (208) 23W sunslate roofing shingles.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62616	12041-10000-25503	8015 S SEPULVEDA BLVD	90045	11	099B165   597	4108027007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00, 2770.00	Electrical	Electrical	Commercial			10/24/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	33.9664	-118.39647	TI in the office area of an existing YMCA. EPC is for T24 & emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62617	10041-10000-21094	3000 N VERDUGO ROAD 1-50	90065	13	150B213   720	5456012904	PF-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.02	Electrical	Electrical	Public Safety Only			10/22/2010 12:00:00 AM	12/10/2010 12:00:00 AM		Permit Finaled	12/01/2011 12:00:00 AM	ADDRESS	34.10548	-118.23757	NEW FIRE WARNING SYSTEM FOR A 3-STORIES RESIDENTIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62618	17041-10000-08937	833 W 56TH ST	90037	9	108B197   893	5001010022	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	33.99154	-118.28833	Plan check for PV roof mounted system. System size: 5.0kW with 20 modules with 1 inverter(5.0kW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62619	19041-10000-52101	6977 W LOS TILOS ROAD	90068	4	150B181    34	5549013010	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.11099	-118.34195	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING 200 AMP SERBICE. INSTALLATION INCLUDES 36 MODULES (PANASONIC 330 WATT), 36 MICROINVERTERS (ENPHASE IQ7X), 1 COMBINER BOX, 1 PANEL OF 200 AMPS, AND 1 ENERGY STORAGE SYSTEM,   SYSTEM SIZE: 11.88 KW DC; 11.34 KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62620	17041-10000-16119	1309 W 73RD ST	90044	8	102B197  1303	6019001028	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Issued	05/15/2017 12:00:00 AM	ADDRESS	33.97376	-118.29847	PV SYSTEM TOTAL OF 3.8KW AC USING CENTRAL INVERTER. TOTAL OF 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62621	16041-10002-15463	3650 W MARTIN LUTHER KING, JR BLVD SUITE 187	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Approved	09/01/2016 12:00:00 AM	ADDRESS	34.01118	-118.33649	Changes to approved set, revise the layout and qty of the light fixtures due to the architectural revision in the storage, restroom, and breakroom. All changes noted under Delta-3.* This is Plan check only, permit was issued under the master plan.08/08/16: Changes to an approved set. All changes are clouded under delta A, D, & E. Changes include replacing/relocating lighting fixtures.Note: Original application is under PCIS#16041-10000-15463(((((PC FOR ENERGY ONLY. T.I FOR TIME WARNER CABLE. TRANSFER FROM RETAIL TO TIME WARNER CABLE. TOTAL AREA 3965 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62622	17041-20000-18280	4818 N SATSUMA AVE	91601	2	168B173   396	2421013025	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			06/01/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.15825	-118.36686	New three-story five-unit apartment building.  600 A 120/240V single phase service. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62623	14041-10000-15349	8936 N GLENOAKS BLVD	91352	6	195B173   170	2408005029	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.2312	-118.36756	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT  FOR DOLLAR TREE. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS.  11487 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62624	13041-20000-23548	7463 N VARNA AVE	91605	2	186B157   249	2328027020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.20651	-118.42487	"PV2 100KW 3 PHASE SYSTEM. 400 MODULES AND 1 INVERTER. ""$0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62625	12041-10000-04711	10868 W WICKS ST	91040	2	204B173   368	2542031003	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.25288	-118.36723	INSTALL ROOF MOUNTED 8.64 KW SOLAR AND INTERCONNECT TO MAIN SERVICE PANEL. SINGLE FAMILY DWELLING OF 540 SQFT. MAIN SERVICE WILL BE UPGRADED TO 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62626	14041-10000-03142	6121 W SUNSET BLVD	90028	13	147A189    25	5546026030	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.09818	-118.32309	Installation of a new fire alarm system into the Radio and Business buildings for rehabilitated existing low-rise commercial building.  Applicant can be reached at ext. 112 of phone number under applicant contact info.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62627	12041-10003-09731	811 W 7TH ST 1ST FLR	90017	9	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Expired	03/31/2016 12:00:00 AM	ADDRESS	34.04908	-118.25911	SUPPLEMENTAL PLANCHECK PER INSPECTORS REQUEST. CHANGES TO LIGHTING, 6 CKTS WERE ADDED, AND MINOR CHANGES. SUPPLEMENTAL PERMIT ISSUED UNDER THIS APPLICATION.PLAN CHECK FOR POWER AND ENERGY FOR RESTAURANT ON FIRST FLOOR OF AN HIGH RISE BUILDING. MORE THAN 99 OCCUPANTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62628	13041-20000-25850	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	PC FOR T24 ENERGY ONLY. PART OF HIGH RISE. OPEN CORRIDOR AREA REPLACE EXISTING FIXTURES. NEW LIGHTING. PERMIT TO BE ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62629	12041-20000-03669	127 S SAN VICENTE BLVD Bulletin-143 TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM			PC Approved	02/29/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	Bulletin-143 TI REVISION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62630	19041-10000-46800	1601 S LOS ANGELES ST	90015	14	123A207    32	5133014015	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.03299	-118.26174	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62631	18041-10000-04709	4640 N LANKERSHIM BLVD # 601	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.15499	-118.36841	ALTERATIONS IN OFFICES- NEW CKTS AND LUMINAIRESPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62632	18041-20000-13989	357 S LORRAINE BLVD	90020	4	135B189   389	5504004012	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.06746	-118.32015	Plan check for power only in existing single family dwelling. Service upgrade to 600A.B#17016-20000-20828	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62633	13041-10000-01577	6081 W CENTER DR	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	33.97811	-118.39245	"methane buffer zoneTI - ELECtrical SYSTEM FOR NEW RESTauRaNT. FULL PC FOR POWER/ENERGY 400A+ CONNECTed loadfire alarm separate""COMPLY WITH DEPARTMENT ORDER effective date 07/19/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".tRANSFOREMRS 150KVA EACH BEEN RELOCATED, TRANSFORMERS INSULLATION MEET CODE SECTION 450.21 B, ACCESS AND VENTILLATION PROVIDED ALSO."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62634	13041-10000-26549	901 E E ST	90744	15	030B209   720	7424014090	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	33.77631	-118.25153	New cold dock addition.  New demand load below 400A.  Title 24 plan check AND PERMIT for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62635	14041-20000-19531	17544 W RAYMER ST	91325	12	192B129    70	2787024012	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Expired	08/23/2016 12:00:00 AM	ADDRESS	34.22619	-118.51743	14.28 KW PV1 roof-mounted system; changes from  previous approval plan ( 14041-20000-13007), changing from (42) Trina Solar TSM-255p to (56) TSM-255p module and (2) Power One Aurora PVI3.6-OUTD to Power One Aurora PVI6000 and 5000-OUTD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62636	16041-10000-41785	1882 S COCHRAN AVE	90019	10	126B177   720	5067020018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.04209	-118.35452	PV INSTALL NEW 23.544 KW DC/23.040 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(72) AC MODULES: SPR-E20-327-C-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62637	19041-20000-14381	4070 N WILKINSON AVE	91604	2	165B165  1248	2367010014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.14484	-118.40401	Plan check for battery back up system in to existing PV System, install 3 Power Wall 2.0(13.5KWh)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62638	13041-10000-04237	2710 S SEVERANCE ST 1ST & 2ND	90007	9	121-5A201  14	5123003411	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM			PC Approved	02/27/2013 12:00:00 AM	ADDRESS	34.02896	-118.28161	REMODEL CORRIDOR/OFFICES ON 1ST AND 2ND FLOORS IN THE HONOR'S HOUSE RESIDENCEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62639	11041-20000-15741	14006 W RIVERSIDE DR # 77	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM	07/29/2011 12:00:00 AM		Permit Finaled	08/31/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check T24 Energy/Emergency T.I. convert (E) retail space to barber shop suite #77	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62640	18041-20002-00459	13209 W MOORPARK ST	91423	4	165B157   317	2360030039	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1434.00	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	34.15049	-118.42075	PLAN CHECK ONLY, CHANGES TO APPROVED SET OF PLANS. CHANGES TO LIGHT FIXTURE SCHEDULE, TITLE 24 INSTALLED WATTAGE PAGE, AND MINOR CHANGES TO FLOOR PLAN AND PANEL SCHEDULE HPL. CLOUDED DELTA E1 CHANGES ONLY.*ORIGINAL*Plan check for 6 units appartment 600 A Service 3 story. Total area: 5,649 sq ft. B#17010-20000-03441	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62641	15041-20000-32734	9185 N BURNET AVE	91343	7	198B145   451	2656023***	(Q)RD2-1, RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Expired	10/31/2017 12:00:00 AM	ADDRESS	34.23689	-118.46358	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62642	19041-20001-14515	9937 N SHIRLEY AVE	91324	12	201B117    16	2726013009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2019 12:00:00 AM			PC Approved	09/20/2019 12:00:00 AM	ADDRESS	34.25111	-118.55925	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO WORK DESCRIPTION. CHANGE FROM TESLA TO LG CHEM BATTERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62643	18041-10001-11270	7754 W MCGROARTY ST	91042	7	204B193  1421	2563002005	RE15-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.2521	-118.30204	"Plan check for T24 only and supplemental permit for TI on (E) building for bible study classrooms, office and restroom. Install (2) new panels to replace the existing vandalized panels and to accomodate new loads that are less than 200A.<<<<Express permit:    REWIRING (150) EXISTING  ELECTRICAL CIRCUITS FOR RECEPTACLES/OUTLETS""COMPLY WITH DEPARTMENT ORDER effective date03/23/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62644	17041-10000-34904	10250 W SANTA MONICA BLVD #1420	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for power and energy on a first time tenant ""Orange Theory fitness"" ste# 1420"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62645	16041-20000-34081	15760 W VENTURA BLVD Ste 1450	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.1552	-118.47684	Existing commercial office remodel.  New lights, existing circuits.  Highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62646	10041-20000-19703	6630 N INDEPENDENCE AVE	91303	3	180B109   352	2148026043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM	10/04/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	34.19085	-118.5904	outdoor enegy plan check parking lot area	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62647	14041-20001-01342	13172 W VAUGHN ST	91331	7	213B157   100	2524007002	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	PIN	34.28340913	-118.41953629	(((Expedite fees)))PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62648	18041-20001-26817	9857 N MASON AVE	91311	12	201B109   132	2748005020	(T)(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.24955	-118.58012	08-12-2019 Changes to an approved set of plan, Changes include addtional lighting to the site light(landscape lighitng Except from outdoor title 24) and install receptacle for future load to the tree. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62649	13041-10001-16921	3540 E MISSION ROAD	90031	1	136-5A227  63	5211021901	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	PIN	34.06665286	-118.20074688	PLAN CHECK ONLY. CHANGES TO APPROVED SET. CHANGING POLE MOUNTED LUMINAIRES TO LED LIGHT FIXTURES. TYPE A , B , AND C ONLY. T24 CHANGES ONLY.Outdoor parking lot lighting.  Title 24 plan check only.  Permit to be issued  at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62650	14041-20000-01099	7301 N QUARTZ AVE	91306	3	186B117   864	2115010018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2014 12:00:00 AM			PC Approved	01/31/2014 12:00:00 AM	ADDRESS	34.20309	-118.56466	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.application in error	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62651	16041-10001-40624	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM			Permit Finaled	02/20/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	title 24 and emergency lighting for west field concession space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62652	18041-20000-04869	622 W 17TH ST	90015	9	124-5A205  63	5126001013	CM-1	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.03672	-118.27164	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62653	18041-20000-34145	14440 W BURBANK BLVD	91401	4	174B149   910	2245007027	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1285.00	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/19/2018 12:00:00 AM	ADDRESS	34.17189	-118.44778	Plan check for Title 24 only. Project site is an existing commercial space with an existing retail building. Project scope is a tenant improvement. Total lighting area = 424 sq. ft.Note: Building application has been generated under 18016-20000-20285	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62654	18041-20002-09817	11051 W PENDLETON ST	91352	6	198B173    32	2538011020	[Q]M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM			PC Approved	10/31/2018 12:00:00 AM	ADDRESS	34.23953	-118.37198	10/12/2018  Revisions to approved set of plans clouded and identified as delta 2.  Downsizing of system to 1.885 MW AC and changes to SLD feeder wiring details. ((((Plan check for a PV2 roof-mounted FiT PV system. System size is 1.910 MWac/2.107 MWdc and consists of (19) inverters, (5,472) modules, and (5) load centers.$0 permit fee per State Senate Bill SB 1222.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62655	18041-20000-14413	22320 W ITASCA ST	91311	12	201B101   520	2727008002	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Issued	04/19/2018 12:00:00 AM	ADDRESS	34.24432	-118.61332	Plan check battery back up system Powerwall 2.0. installed into existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62656	15041-20000-05686	6141 N KESTER AVE	91411	6	178-5A149 317	2242024048	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			Reviewed by Supervisor	03/26/2015 12:00:00 AM	ADDRESS	34.18203	-118.45769	Plan check for power only.  1600 A service upgrade to existing commercial building.  New switchgear and subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62657	19041-10000-51494	1347 N GLENDALE BLVD	90026	13	141A209   719	5419032002	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1956.00	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	02/06/2020 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.07959	-118.26048	T.I. PC FOR ENERGY. TOTAL AFFECTED AREA 2160sqft. SCOPE OF WORK INCLUDES ADDITION OF NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62658	15041-20001-22334	1000 S CARMELINA AVE	90049	11	126B141   123	4264021031	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	ADDRESS	34.0441	-118.47284	Expedited per applicant request.Plan check for the addition of a 3 kWac system onto an existing 3 kWac system. Total system size is 6 kWac. New 3 kWac system consists of (1) inverter, (14) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62659	19041-10000-11346	4300 W PICO BLVD	90019	10	129B185  1083	5082015026	C4-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2181.10	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.04779	-118.32859	Remove HID fixtures and replace with new LED fixtures (Indoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62660	19041-10000-29436	9400 N TAMPA AVE	91324	12	198B117   101	2762022033	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.24092	-118.55325	PV1, NEW ROOF MOUNTED SYSTEM. SYSTEM SIZE IS 3.705 KWdc/ 3.149KWac. SCOPE OF WORK INCLUDES 16 MODULES (HANWHA 285 WATT MODULE) WITH MICROINVERTERS (ENPHASE IQ7)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62661	16041-10000-30217	6600 N TOPANGA CANYON BLVD Westside-Entrance	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW EXTERIOR LIGHTS FOR ENTRY COURTYARD SPACE ON THE WEST SIDE OF THE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 823 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62662	14041-20000-20803	9301 N TAMPA AVE Ste 146	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI to (E) commercial restaurant space (yogurt shop).  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62663	14041-10002-10134	910 S LINCOLN BLVD	90291	11	111B145   877	4243004033	[Q]C2-1-CDO, [Q]P-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM			PC Info Complete	03/31/2015 12:00:00 AM	ADDRESS	33.99868	-118.46193	REVISIONS TO PERMITTED SET OF PLANS CHANGES INCLUDE DIFFERENT TTPES OF LUMINIRES, NEW PANELBOARDS, CIRCUITS AND HVAC UNITS.CHANGES ARE CLOUDED ON THE PLANS))))))))Plan check for power and energy for remodel of existing Ralph's store.  Total new/revised connected load exceeds 400 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62664	10041-10000-20893	13455 W MAXELLA AVE Unit # 270	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM			Corrections Issued	11/01/2010 12:00:00 AM	ADDRESS	33.9867	-118.44159	"TI of an existing ""AMC Marina 6"" Theatre building.   Plan Check is for Power & Energy.  <<<<Fire Alarm System submitted under 10041-10000-20900>>>>>>Modification to seperate fire alarm has been filed."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62665	12041-10000-12386	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check for installation of  pre-action and deluge control and detection devices, (Fire alarm and sprinkler control). LAX Tom Bradley Terminal	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62666	19041-20001-44164	7415 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM			PC Approved	11/26/2019 12:00:00 AM	ADDRESS	34.2052	-118.49233	Expedite per appliant request Plan check for PV roof mounted system FEED IN TARIFF (FIT), PV system size: 163.2KW DC, 148.05KW AC CEC with 408 PV Modules and 4 inverters(33.3KW), Service size: 400A for Feed In Tariff. Building Castle & Cooke Aviation	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62667	18041-10000-05224	2025 S AVENUE OF THE STARS N. TOWER	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	10/12/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	PLAN CHECK FOR POWER AND ENERGY TO PHASE 4A ( NORTH TOWER) 45 STORY  CONDO BUILDING WITH 160 CONDO  & 5 HOUSE KEEPING UNITS. SERVICE EQUIPMENT IS APPROVED UNDER SEPARATE PERMIT.  TOTAL SQ. FT. 127028.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62668	16041-20000-44625	2510 W TEMPLE ST	90026	13	138A205   190	5157008029	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.07192	-118.27348	PV2.  Install 30 kW roof mounted grid tied PV system.  (90) modules with (2) 15 kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62669	16041-10003-16945	14006 W RIVERSIDE DR #20	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM			PC Info Complete	09/19/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	"09/19/2016 Changes to an approved set of plans . Changes include additional current limitting panels and branch circuits to panel ""A"". Changes apply to Delta 3 only. (((((((PC FOR RETAIL. EYEGLASS STORE WITH 1 EYE EXAM ROOM. PC FOR POWER AND ENERGY.)))))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62670	17041-10000-08423	19414 W VENTURA BLVD	91356	3	174B117   653	2163002058	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.17247	-118.55634	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 64,725 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62671	11041-20000-07950	1888 CENTURY PARK EAST 3RD FLR	90067	5	132B161    14	4319001006		West Los Angeles				2671.00	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	PIN	34.06139499	-118.41373129	BATHROOM REMODEL ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62672	11041-20000-01577	12400 W WILSHIRE BLVD	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	03/11/2011 12:00:00 AM	ADDRESS	34.04157	-118.47031	energy plan check # 360 and 365	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62673	16041-10000-34768	1664 W WASHINGTON BLVD	90007	1	126B197   712	5075036008	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.03979	-118.29354	Plan check power only new service 2000A in existing commercial space. RECONNECTING EXISTING LOADS. CHECKING FOR NEW FAULT CURRENT VALUES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62674	18041-20002-48746	14930 W DRELL ST pv1	91342	7	225B149   137	2502008034	RA-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2019 12:00:00 AM			PC Approved	01/30/2019 12:00:00 AM	ADDRESS	34.3156	-118.45773	Change of busbar rating to main service panel to 225A.  Delta-1 revision only.  Plan check fee $0.00 due to California Senate Bill 1222 and AB 1414.(((pv1install roof mounted pv system sized 5.985KW with 19 PV Modules, 1 inverter(7.6KW) and 27KWH Energy Storage System interconnected with msp.(2) tesla 13.5KWh batteries)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62675	15041-20000-20767	21550 W OXNARD ST suite 670	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.179	-118.60001	TI enerhgy plan check suite 670	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62676	15041-20000-27027	5022 E YORK BLVD	90042	1	156A225   320	5477001006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.1212	-118.20615	PLANCHECK FOR T24 ENERGY ONLY. RESTAURANT.  PLANCHECK ONLY DUE TO LOST SET. NOT A FIRST TIME TENANT PER APPLICANT. 2090 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62677	14041-20000-08331	6673 N BOBBYBOYAR AVE	91307	12	180B093   224	2036003012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.19186	-118.63272	PV1.  Install 7.5 kW roof-mounted PV system, connect with main service panel.  Transformerless inverter: SE6000A-US-ZB-U with power optimizers.  30 modules: Canadian Solar CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62678	14041-20000-28669	16550 W VENTURA BLVD SUITE 322	91436	5	168B137   369	2284005025	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.15764	-118.4942	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING LIGHTING AND OUTLETS.  2049SQFT, WORK TO BE PERFORMED IN SUITE #322 ON THE THIRD FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62679	15041-10000-27193	10250 W SANTA MONICA BLVD # 168	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	PIN	34.0586034	-118.41904766	alterations in an existing jewelry store plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62680	17041-20002-45614	16025 W VENTURA BLVD	91436	5	168B141   547	2261022022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.15641	-118.48198	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGE IN LIGHT FIXTURE LAYOUT, LIGHT FIXTURE SCHEDULE, LIGHT QUANTITY, AND LIGHT MODELS. UPDATE TO T24 CALCS. RELOCATION OF ROOFTOP EQUIPMENTS. CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62681	15041-10002-01070	12510 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.97839	-118.4121	((((5/10/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO ENERGY CALCULATIONS, OCCUPANCY SENSORS AND LIGHTING SWITCHES.  THE CHANGES APPLY TO ALL THE FOLLOWING APPLICATION NUMBERS AS NOTED BELOW.Plan check for power and energy. Project is (1) of (7) buildings; the building is 4 stories and consists of 6 units. New service size of 600 amps.Fire alarm variance submited. Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62682	13041-20000-25632	12847 W ADMIRAL AVE PV1	90066	11	105B157   272	4223012009	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Expired	10/13/2015 12:00:00 AM	ADDRESS	33.98601	-118.42816	ROOF MOUNTED SOLAR, (21- MODULES) 5.25KW.  Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. (((CHANGE TO MICROINVERTER. PC WITH PERMIT FOR NEW SOLAR SUBPANEL)))((( ORIGINAL PERMIT FOR PV SYSTEM ALREADY ISSUED UNDER APPLICATION # 13041-10000-22172))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62683	19041-10000-30682	21040 W CALIFA ST	91367	3	174B105     8	2149002021	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM			PC Approved	08/07/2019 12:00:00 AM	ADDRESS	34.17715	-118.59163	TENANT IMPROVEMENT IN OFFICE-CORRIDOR,PANTRY , BATHROOMS,OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62684	18041-20000-02990	221 N FIGUEROA ST #1350	90012	14	133-5A211 255	5161006909	C4-2D, [T][Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for Title 24 only. Project site is a suite on the 13th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,675 sq. ft.Note: Building application has been generated under 17016-20000-34039	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62685	19041-20000-21001	4118-4120 S CENTRAL AVE	90011	9	115-5A209 430	5115025005	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.10	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.00861	-118.25627	TI to (E) bakery/commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62686	18041-10000-02453	6330 N VARIEL AVE	91367	3	180B105    69	2149003009	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Issued	01/23/2018 12:00:00 AM	ADDRESS	34.18601	-118.59256	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62687	18041-20001-01553	17064 W MINDORA CT	91344	12	216B133   258	2606022013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.28934	-118.50441	Expedited plan check fee. PV1.  Install new 7.92 kW DC/7.04 kW AC roof mounted grid tied PV system with center-fed panelboard connection.  (22) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62688	14041-10000-12680	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	33.78054	-118.23195	PLAN CHECK FOR INSTALLING NEW PANEL AND EQUIPMENT IN WILMINGTON REFINERY. HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62689	17041-10000-07968	735 S FIGUEROA ST #150	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.04878	-118.26079	RETAIL TI. NORDSTROM. NEW DISTRIBUTION EQUIPMENT. PC FOR POWER AND ENERGY. Total area 26450 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62690	14041-20000-32216	20173 W VIA GALILEO	91326	12	219B113    72	2701042015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.29554	-118.57328	PV1 SFD. TOTAL SYSTEM SIZE 4.3KW DC/ 3.6KW AC USING 17 MODULES. CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 400A PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62691	19041-10000-38340	15223 W BURBANK BLVD	91411	4	174B145   446	2243008008	C2-1VL-RIO, R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM	08/05/2020 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.17229	-118.46482	TENANT IMPROVEMENT OF AN EXISTING SINGLE STORY RETAIL SPACE. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.  TOTAL  AREA: 3,922 SQR FT.BULDING PERMIT: 19016-10000-30382	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62692	19041-20000-21783	23236 W CANZONET ST	91367	3	171B093   292	2044017009	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.1663	-118.63326	PV1.  Install 12.87 kW DC roof mounted grid tied PV system.  (39) modules with 10 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62693	19041-20000-04792	4108 N KRAFT AVE	91604	2	162B169   204	2368020023	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2019 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.14276	-118.37992	Plan check for power only. Project site is a single familt dwelling. Project scope is the addition of (2) battery back-up units to an existing PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62694	17041-20000-31872	13207 N BRADLEY AVE	91342	7	225B145   352	2501005009	[Q]MR1-1, [Q]P-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.31041	-118.46654	permit fee $0.00 by state senate bill no. 1222Plan check for solar pv system, roof-mounted on commercial building.683kW ungrounded system [(11) 60kW + (1) 23kW inverters].(2,546) 340W pv modules. Line side tap.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62695	18041-30001-47306	970 W 190TH ST Suite 550	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	33.85812	-118.29302	01/17/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1 and 2. Scope of work has expanded to include more square footage.PLAN CHECK ONLY - NO PERMIT TO BE ISSUED.*****Original Work Description*****Plan check for Title 24 only. Project site is a tenant suite in an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 4,510 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62696	18041-20000-07781	20648 W CHESTNUT CIR (#335)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.29337	-118.58436	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62697	17041-20000-24333	20257 W JUBILEE WAY	91326	12	216B113     9	2701002069		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.28352	-118.57523	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.48 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62698	16041-10000-06388	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	PIN	34.0586034	-118.41904766	FULL PC FOR A NEW THREE STORY NORDSTROM DEPT STORE TO BE A NEW MAJOR TENANT ON THE SOUTH END OF THE EXISTING CENTURY CITY MALL; SHELL UNDER SEPARATE PERMIT; SCOPE OF WORK INCLUDES A NEW 3000 AMP SERVICE, 480/277V 3PHASE 4W. PERFORMANCE METHOD IS BEING USED FOR ENERGY CALCULATIONS. TOTAL AREA: 143060 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62699	18041-20000-45629	11246 W OTSEGO ST	91601	2	171B173   913	2353013003	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.16279	-118.37612	Plan check for new fire alarm system for 70 units 6 stories apartment building. Total fire alarm devices: 130 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62700	10041-20000-15648	8141 S GULANA AVE	90293	11	096B153     1	4115021800	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	33.96169	-118.43753	Plan check for installation of process equipment in hazardous classified area at Los Angeles Sanitation District. Low voltage equipment/wiring not plan checked. Permit includes low voltage wiring.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62701	16041-10000-45410	1003 E 4TH PL	90013	14	127-5A217  55	5163018002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			Reviewed by Supervisor	02/06/2017 12:00:00 AM	ADDRESS	34.04219	-118.23383	Resubmitted due to more than 50% electrical design change from the original, service size changed to 1600A, adding more equipments and fire pump.  New plan check under   17041-10000-37146, permit will be under this new number <<FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW CONSTRUCTION, DESIGN BUILD 216 STALL PARKING STRUCTURE (6 LEVEL PARKING WITH A 2 STORY (33,537 SF) OFFICE BUILDING ABOVE IT - BUILDING IS 8 STORIES TOTAL.)  SERVICE SIZE = 4000A. TOTAL SQ FT. 82143>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62702	18041-20000-38477	18784 W TRIBUNE ST	91326	12	207B121   150	2717023026	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.26668	-118.54296	Plan check for a PV1 roof-mounted PV system. System size is 15.525 kWdc/13.967 kWac-CEC and consists of (45) modules, (45) micro-inverters, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62703	14041-10000-18038	6725 W SUNSET BLVD #420/430	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.09814	-118.33717	Title 24 plan check only. Total area = 4372 sq. ft. Tenant improvement to office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62704	18041-10000-07133	716 S BROADWAY	90014	14	127-5A211  81	5144015035	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Info Complete	08/27/2018 12:00:00 AM	ADDRESS	34.04465	-118.25364	PC FOR CORE AND SHELL OF AN EXISTING BUILDING. SCOPE INCLUDES SERVICE UPGRADE TO2000A, 120/208 3P, NEW PANELS,  AC'S EQUIPMENT, RECEPTICALS, LIGHTS AND WIRING .TOTAL AFFECTED AREA IS 70322 SQ.FT INDOOR-OUTDOORB#16016-10000-26342	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62705	19041-20001-29284	6430 N BELMAR AVE	91335	3	180B117   786	2131027010	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM			Reviewed by Supervisor	08/07/2019 12:00:00 AM	ADDRESS	34.18766	-118.55812	Expedited plan check fee.PV1.  Install 5.44 kW roof mounted grid tied PV system and 9.8 kWh energy storage system.  (17) modules with 5.0 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62706	19041-20000-09787	5022 N WHITSETT AVE	91607	2	171B165  1270	2356023032		South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	10/15/2021 12:00:00 AM	ADDRESS	34.1619	-118.40506	Plan check for new fire alarm system for 9 units and 3 stories, new fire alarm devices: 50 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62707	14041-10001-29098	1200 N CHICKORY LANE	90049	11	141B137   120	4493025008	RE15-1-H, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.08085	-118.4859	Expedited plan check for RSES per applicant request. PV1.  Install 20.4 kW roof-moutned, utility-interactive PV system.  (2) transformerless inverters with DC-DC converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62708	17041-10000-02466	918 E 61ST ST	90001	9	105B209   121	6007008005	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	PIN	33.9841518	-118.25856453	PC FOR 800A SERVICE TO THE BUILDING. REFEED EXISTING LOADS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62709	14041-10000-25852	8220 N WOODMAN AVE	91402	6	192B157   780	2213021019	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.22035	-118.43224	Title 24 plan check for an office T.I building. lighting retrofit from existing fixture to LED retrofit kits. Total remodeling area covers 5567 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62710	15041-20000-11998	20403 W VIA MEDICI	91326	12	219B109   291	2701056010	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Expired	06/02/2017 12:00:00 AM	ADDRESS	34.29512	-118.57908	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (28) Kyocera KU 260-6 <odules(1) PVI-6000 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62711	16041-20000-24956	5340 S ALLA ROAD	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	33.9773	-118.42567	Plan check for energy only. New exterior lighting on soffits for south and east sides of the building. Ground floor and second floor. 6,108sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62712	18041-10000-10604	16620 W STAGG ST	91406	6	189B137   108	2205009079	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.21302	-118.49616	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62713	17041-20001-46290	6150 N LAUREL CANYON BLVD BLDG J	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.18223	-118.39491	Changes to an approved set set of plan, changes include addtion of feeder schedule for Aluminum, reconfigured inside electrical room, remove electrical distribution. all changes has been clouded delta 3. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62714	17041-10000-08333	2415 S CENTRAL AVE	90011	9	118-5A209  70	5131021001	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	05/24/2022 12:00:00 AM	ADDRESS	34.02013	-118.25455	PC TI FOR T24 ONLY  FOR NEW OFFICE AREA. TOTAL AREA IS 4573 SQFT AND LOAD IS UNDER 400A.**CHANGE OF USE FROM RETAIL TO OFFICE. REMODEL FIRST FLOOR, MEZANINE AND STAIRS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62715	12041-10000-11616	8500 W BEVERLY BLVD #743	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	08/22/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	REMODEL OF (E) RETAIL SPACE: DEMOLITION OF (E) NON STRUCTURAL WALLS, (E) INTERIOR FINISHES AND (E) PARTIAL STOREFRONT AND ENTRY DOORS; WORK INCLUDES (N) NON STRUCTURAL WALLS, (N) CEILING/ CEILING FIXTURES, (N) INTERIOR FINISHES <SEE COMMENTS>PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62716	19041-10000-53383	16706 W ROSCOE BLVD	91406	6	192B133   255	2205006904	[Q]M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		9800.08	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	08/12/2020 12:00:00 AM		Permit Finaled	08/07/2021 12:00:00 AM	ADDRESS	34.22008	-118.49713	FULL PLAN CHECK FOR A 2500A UNDERGROUND SERVICE WITH 3 DISTRIBUTION BOARDS; TWO RATED FOR 800A  AND ONE 1000A, 4 PANEL BOARDS, 2 TRANSFORMERS, AND CIRCUITS.  TOTAL AFFECTIVE AREA: 106,000 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62717	11041-10000-18460	8500 W BURTON WAY 1-88	90048	5	138B173  1128	4334016087	(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Apartment			08/30/2011 12:00:00 AM	09/15/2011 12:00:00 AM		Permit Closed	12/12/2012 12:00:00 AM	ADDRESS	34.07095	-118.37677	TEMPORARY POWER FOR THE CONSTRUCTION SITE OF A NEW 88-UNIT APARTMENT BUILDING.  PLAN CHECK IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62718	16041-20000-41097	1880 S CENTURY PARK EAST 14TH FLOOR	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.06144	-118.41437	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOM. 470 SQFT. 14TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62719	18041-10000-16182	14827 W VICTORY BLVD	91411	6	180B149   786	2236020017	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	05/11/2021 12:00:00 AM	ADDRESS	34.18681	-118.45621	NEW FIRE WARNING SYSTEM FOR 9-UNITS, 4-STORIES APARTMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62720	15041-20000-31335	18145 W MARILLA ST	91325	12	201B125   251	2764018020	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.2474	-118.52933	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62721	16041-20001-38888	10730 N MEMORY PARK AVE	91345	7	207B145   239	2649003028	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Apartment			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	34.26537	-118.46322	4.25.2017 - Plan check for modification to approved set. 400A MSP is not split bus, update SLD to reflect change.======Plan check for installation of solar pv system, roof-mounted on apartment. Interconnect with 400A MSP (200A split bus). 13.6kW ungrounded system. (50) 335W pv modules. Each module has a 400W power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62722	18041-30000-26599	2728 N FLETCHER DR	90039	13	151-5A211  83	5436031016	[Q]C2-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Apartment			07/17/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	11/18/2018 12:00:00 AM	ADDRESS	34.11066	-118.2508	Install rooftop solar system in a commercial building,  9.3 kW AC/ 8.47 kW CEC AC, (26) modules, (13) microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62723	18041-10001-00126	7735 N WINNETKA AVE	91306	3	189B113  1111	2107022078	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM			PC Approved	02/21/2018 12:00:00 AM	ADDRESS	34.21153	-118.57129	expedite per applicant request.NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 44 MODULES (REC SOLAR REC285TP2, 285W), OPTIMIZERS (SOLAR EDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE11400A-US). SYSTEM SIZE IS 11.4KWac AND 12.32KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62724	17041-10000-28009	302 N LAVETA TER	90026	1	135A209    32	5160003008	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.06578	-118.26009	PC FOR FA IN SINGLE STORY COMM. BUILDING. SCOPE INCLUDES 45 DEVICES AND ONE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62725	14041-20000-11631	7900 W SUNSET BLVD	90046	4	147B177  1008	5554001001	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.09788	-118.36194	T. I. TO (E) RETAIL & ADD COFFEE/YOGURT AREA WITHINpc for T24 energy only. new lighting. per engineer, no work done with emergency lighting. emergency to remain. field verify integrety of existing emergency lighting.Note: Permit is under 14041-20000-28914	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62726	19041-10000-01843	4201 W WILSHIRE BLVD # 400	90010	4	135B189   972	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.06189	-118.31911	T-24 ONLY PLAN CHECK FOR AN EXISTING OFFICE INTERIOR TENANT IMPROVEMENT. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT. TOTAL AFFECETED AREA IS 9880 S/FB# 18016-10000-41222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62727	16041-10001-26424	2117 S GLENDON AVE	90025	5	126B157    93	4321012041	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Issued	05/18/2017 12:00:00 AM	ADDRESS	34.04523	-118.43168	Installation of new roof-mounted solar PV system on a single family dwelling.  Microinverter system.  Total system size = 8 kWac.online permit pulled under 16041-90000-26424 for 24 modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62728	15041-10000-26505	705 N ALFRED ST 1-2	90069	5	141B173   423	5528001054	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM			PC Info Complete	08/19/2015 12:00:00 AM	ADDRESS	34.08391	-118.3755	TI TO AN EXISITNG TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS. PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 3571.2008 STANDARDS APPLY PER INSPECTOR RODNEY SABEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62729	18041-20001-35301	4532 N WESTCHESTER DR	91364	3	166-5A111  15	2174016034	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM			PC Approved	10/02/2018 12:00:00 AM	ADDRESS	34.15237	-118.58225	Expedite per applicant requestPlan check for PV roof mounted system, system size: 15.289KW AC CEC with 52 PV Modules and 2 inverters(7.6kW and 5.0kW) connected to MSP 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62730	17041-20002-30131	17031 W GUNTHER ST	91344	12	213B133   130	2607002033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.28343	-118.50347	Supplemental to relocation of equpment and single line diagram changes. PV1.  Install 3.0 kW roof mounted grid tied PV system.  (11) modules with (1) SolarEdge 3kW rated string inverter.  3.0 kW system is being added to an (E) PV system.  Install 13.5 kWh rated energy storage system with automatic load control relay.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62731	17041-20000-19175	9550 N DONNA AVE	91324	12	201B121   689	2762033033	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Issued	06/23/2017 12:00:00 AM	ADDRESS	34.24446	-118.54735	0$ fee due to senate bill 1222Plan check for roof-mounted solar pv system on SFD.12kW ungrounded system. (43) 290W pv modules.Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62732	15041-10000-15605	21263 W ERWIN ST	91367	3	177B105    20	2149001029	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.18302	-118.59459	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING MEDICAL OFFICES.  NO PATIENT CARE AREA  AND NO LIFE  SUPPORT EQUIPMENT.  STRICTLY CONSULTATION ONLY.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2869. ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62733	10041-20001-13732	22601 W LASSEN ST	91311	12	204B097    41	2724005902	A1-1XL	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM			PC Approved	07/26/2010 12:00:00 AM	ADDRESS	34.25009	-118.61925	Revision to approved set. Adding few addintional lights. Existing permit. TI IN CEMETRY. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62734	13041-20000-21989	1000 W FRANCISCO ST PV-2	90502	15	057B197    63	7351034058	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	33.84969	-118.29414	"PV2 833KW. ROOFMOUNT. COMMERCIAL WAREHOUSE BUILDING. BIPOLAR SYSTEM. 4424 MODULES:  CANADIAN SOLAR 250 60 CELL. 1106KW DC. INVERTER: ADVANCED ENERGY SOLARON AE 500NX & AE333NX.WILL FILE VARIANCE TO SHOW THAT NEW SERVICE IS ONLY FOR PV USE""ZERO FEES DUE TO 2012 SENATE BILL NO. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62735	15041-10000-42455	10545 W AYRES AVE	90064	5	126B157   378	4318002016	R2-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.04347	-118.42029	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3KW INTERCONECTED WITH MSP.(20) SILFAB SLA 260W MODULES(20) ENPHASE 215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62736	17041-10000-12032	10250 W SANTA MONICA BLVD # 1825	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check (Power+Energy) for first time tenant at Westfield Century City, Ste. 1825 ""Suite Supply"", total area 3,959 sq.ft. MS ELA33"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62737	15041-10000-31487	888 S WAYS ST	90731	15	015B205     7	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	10/09/2015 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.73789	-118.26549	T-24, TI TO AN (E) COMMERCIAL FOOD PREPARATION BUILDING. SCOPE INCLUDES A NEW ADDITION TO AN (E) SPACE. NEW PANELS AND 45KVA TRANSFORMER, LOAD <400AMPS. PC FOR ENERGY ONLY. TOTAL SQ. FT. 1876	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62738	13041-10000-15242	1505 S PERRINO PL BLDG B	90023	14	118-5A219  10	5169015014	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Issued	09/27/2013 12:00:00 AM	ADDRESS	34.02018	-118.22248	PV2 COMMERCIAL ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 134.52 KW DC CONSTISTING OF 456 MODULES AND TWO INVERTERS. SINGLE STORY BUILDING A. [MODULES: S-ENERGY # SM-295PC8 |||| INVERTERS: SOLECTRIA # PVI-50KW AND SOLECTRIA # PVI-85KW]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62739	19041-20000-50826	15260 W VENTURA BLVD #800	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.15356	-118.4658	TI REMODEL, T24 INCLUDED, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 3530 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62740	12041-20001-05405	22601 W LASSEN ST	91311	12	204B097    41	2724005902	A1-1XL	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM			PC Approved	08/27/2012 12:00:00 AM	ADDRESS	34.25009	-118.61925	Changes from previously approved plans (energy only).  Per applicant request, plan check for power only.  Install new outdoor 112.5 KVA transformer.*****Plan check for T-24 energy compliance including emergency egress and exit lights, main service = 400A. NEW MACHINE SHOP BLDG *****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62741	10041-20000-01241	9001 N TAMPA AVE	91324	12	195B117    25	2783028013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Closed	11/15/2012 12:00:00 AM	ADDRESS	34.23383	-118.55386	Upgrading existing 1200 amp service to 2500 amp. Installing new panels, circuits and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62742	17041-30000-10239	3001 N ARROWHEAD DR	90068	4	156B185    95	5577035036	RE15-1-H	Central	Hollywood	Hollywood United	Yes	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.1238	-118.32884	Plan check for power only. Project site is an existing single family dwelling. Project scope is a complete electrical re-wire and new distribution equipment.Note: Building permit has been pulled under 15016-10000-15726	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62743	10041-10000-25753	630 W HARRY BRIDGES BLVD	90744	15	027B205   442	7440006***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			Corrections Issued	03/03/2011 12:00:00 AM	ADDRESS	33.77068	-118.26868	New 4 story office building for the port of LA. EPC is for Power and Energy. (Fire alarm plan was submitted under separate application)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62744	10041-10000-20097	440 S VERMONT AVE #102	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	New 3 story retail building and basement with levels 2 and 3 as parking. Level 1 Methane. fist time tenant for unit 102 restuarant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62745	15041-10000-02745	8216 N TUJUNGA AVE	91352	6	192B173   825	2314001900	M2-1-G, M3-1-G, [T]P-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.21982	-118.37892	Title 24 plan check only.  Total area = 2280 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62746	13041-20000-27434	725 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR T24 ENERGY ONLY. RESTROOMS. WORK DONE ON 40TH FLOOR OF HIGH RISE. EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62747	19041-10000-40915	8500 N BALBOA BLVD #130	91325	12	192B133    33	2689019019	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.22485	-118.50045	T-24 PLAN CHECK FOR A T.I. OF AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 11777 SQ.FTB#19016-10000-27608	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62748	12041-20000-23474	10544 N HASKELL AVE	91344	12	207B141   612	2661004013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	34.2624	-118.4759	Enphase PV system on roof of single family dwelling and a detached garage, and new PV subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62749	18041-10000-35255	614 E TERMINAL WAY Main-Substation	90731	15	018B205    54	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	33.74201	-118.26431	PLANCHECK FOR POWER ONLY.  FLYWHEEL ENERGY STORAGE EQUIPMENT AT PORT OF LOS ANGELES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62750	14041-10001-33659	17732 W MELVIN LANE	91325	12	195B129   337	2768012038	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM			PC Approved	02/25/2015 12:00:00 AM	ADDRESS	34.23045	-118.52155	Sup. application for expedite fees only.Installation of roof mounted solar PV array in addition to existing system.  1 new load center, 3 new inverters, and 69 new modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62751	18041-10000-46412	2503 E CESAR E CHAVEZ AVE	90033	14	129A225   349	5177033024	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.04597	-118.20551	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62752	16041-20000-34044	6433 N DUNLO PL	91307	12	180B085    87	2032005008	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.18731	-118.66009	PV1.  Install 8.2 kW rated PV system.  (38) modules with (1) 8.2 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62753	16041-10000-20402	2930 W ROWENA AVE 1-6	90039	4	151-5A205 469	5434035031	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.10834	-118.26924	Install New Fire sprinkling system (1) comm. panel   (6) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62754	19041-20000-11160	6437 N COLUMBUS AVE	91411	6	180B145   701	2235001018	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.18772	-118.46416	Plan check for a PV1 roof-mounted PV system. System size is 12.24 kWdc/10.4 kWac-CEC and consists of (34) AC PV modules and (3) load centers.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62755	17041-20000-11886	7842 N MELBA AVE	91304	12	189B093   505	2020023007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Issued	04/28/2017 12:00:00 AM	ADDRESS	34.21298	-118.63443	0$ permit fees due to seante bill 1222Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (2) inverter, (84) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62756	14041-20001-16704	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.01768	-118.42494	Modifications to approved set.  Change of emergency lighting from bugeye wall packs to emergency battery backup of general lighting fixtures.  Delta-2 revisions.  (((Remodeling the Athletic Center for Windward School.  Install new branch circuits, and lighting.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62757	11041-20000-13606	6000 N WOODMAN AVE	91401	2	177B157   849	2330028017	[Q]C1.5-1VL, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02, 1245.00	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.17962	-118.43105	Plan check for new 800A service supplying existing building with existing tenants and future first time tenants. Future first time tenant subject to complete plan check. Existing panels to remain. Includes misc permit for new feeders to supply existing panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62758	16041-20000-24563	18107 W TOPHAM ST	91335	3	177B125  1044	2124015051	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.18075	-118.52775	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62759	16041-20000-39092	18550 W VALERIO ST	91335	3	186B125   676	2118016001	R1-2	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.2046	-118.53758	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62760	16041-10000-25826	749 S BROADWAY	90014	14	127-5A209  96	5144014028	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.04418	-118.25458	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING RETAIL SPACE. SCOPE INCLUDES 2 COMMUNICATION PANELS, 1 FA PANEL, AND 136 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62761	19041-20001-19305	23115 W OSTRONIC DR	91367	3	171B097   466	2042014035	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM			PC Approved	06/21/2019 12:00:00 AM	ADDRESS	34.16554	-118.6304	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVE SET - CHANGES INCLUDE CHANGING FROM CENTRAL INVERTER TO MICROINVERTERS(IQ7-60-2-US) - CHANGES ARE CLOUDED UNDER DELTA #1ORIGINAL PERMIT PV1.  Install 12.5 kW DC / 10.62 kW AC roof mounted grid tied PV system.  (41) modules with 10 kW rated inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62762	16041-10000-27152	10617 S GORMAN AVE	90002	15	090A217   475	6066020060	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	33.93919	-118.23082	PV1, Installation of A 5.56 KW DC roof-mounted solar system, in a 1 or 2 family dwelling(17) MODULES: SUNPOWER SPR-327NE-WHT-D(1) INVERTER: SMA SUNNY BOY SB5000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62763	17041-30000-32893	200 WORLD WAY Gate 27B	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for power only create new Gate 27B with new passenger borarding bridge at Terminal 2 LAX. new equipments installed mechanical ventelating (180KVA at 480V)and VFD 400HZ(180KVA at 480V) for passenger bridge gate. Total newly connected load added exceed 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62764	15041-20000-12212	9080 N WOODMAN AVE	91331	6	195B153    22	2642031023	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			Corrections Issued	04/27/2015 12:00:00 AM	ADDRESS	34.23488	-118.43984	PLANCHECK FOR T24 ENERGY. OFFICE TI FOR FAST AUTO LOANS. NEW LIGHITNG.  1 STORY.  2484 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62765	16041-20004-26899	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Closed	03/14/2018 12:00:00 AM	ADDRESS	34.32381	-118.49103	PLAN CHECK FOR CHANGES TO TITLE 24 DRAWING SET - SCOPE INCLUDES UPDATING LUMINAIRE FIXTURE SCHEDULE AND LIGHTING UPDATE - CHANGES HAVE BEEN CLOUDED UNDER DELTA 4 1/29/2018changes to an approved set of plans.  changes are noted delta 3.  changes include removal of light fixtures and revised energy calculations.  this id plan check only.  (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,341 sq. ft.Note: Building application has been generated under 16014-20000-03627)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62766	18041-10000-01273	333 S GRAND AVE 44TH FLOOR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	T-24, PC FOR ENERGY ONLY. INTERIOR RENOVATION ON 44TH FLOOR FOR CORRIDOR AND RESTROOMS. TOTAL AFFECTED AREA IS 3086 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62767	15041-10000-19113	16940 W DEVONSHIRE ST	91344	12	204B133   217	2685002016	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.25735	-118.50161	Ti-24 TO AN E COMMERCIAL BUILDING, RALPH STORE. ADDING NEW LED TRACT LIGHT FIXTURES, 12 SQUARE FOOTAGE, 35,000. PLAN CHECK FOR ENERGY ONLY. EMERGENCY LIGHTING TO REMAIN PER APPLICANT. PER NM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62768	16041-20000-09476	5548 N ELMER AVE	91601	2	174B173  1081	2350006010	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			03/17/2016 12:00:00 AM			PC Info Complete	11/07/2016 12:00:00 AM	ADDRESS	34.1714	-118.37619	Plan check for power and energy. Project site is a new 4-story apartment building (3 levels of residential over 1 level of above-ground parking garage). Total lighting area = 7,670 sq. ft.Note: Building application has been generated under 16010-10000-00066	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62769	15041-20000-09943	2222 S COCHRAN AVE	90016	10	126B177  1496	5063009058	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Expired	04/28/2017 12:00:00 AM	ADDRESS	34.03797	-118.35613	Plan check for PV1 rooftop mounted 4.5kW System with 20 modules and microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62770	19041-10000-48362	4953 N CARTWRIGHT AVE	91601	2	168B177    29	2421003011	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.16094	-118.36383	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 29 (SUNPOWER SPR-S400-G AC) MODULES, 29  (SUN POWER SPWR-A4) MICRO INVERTERS, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 11.60KW DC & 10.12KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62771	17041-20001-34504	18145 W GRESHAM ST	91325	12	195B125   523	2769017018	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	ADDRESS	34.23107	-118.52893	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.6kW ungrounded pv system. (19) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62772	17041-20000-43971	11569 N BONHAM AVE	91342	7	213B173   184	2530036025	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.28044	-118.37788	pv1install roof mounted pv system sized 8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62773	15041-10000-13954	13812 W SATICOY ST	91402	6	186B153    43	2214023003	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	ADDRESS	34.20979	-118.43395	ALTERATIONS IN A COMMERCIAL SPACEPLAN CHK IS FORTITLE 24 ;PERMIT WAS OBTAINED ON SEPARATE APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62774	13041-10001-33110	10600 N KESTER AVE	91345	7	207B149   615	2648004016	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.2629	-118.45656	Expedited RSES plan check per applicant request.[][][][]PV1, Install 4.25 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE3800A-US. (17)modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62775	16041-20001-14532	420 S GRAND AVE	90071	14	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.05094	-118.25298	08-02-2016 Changes to an approved set of plans. Changes include addition of 1,600A Section to feed to New UPS, increase size of (4) PDU to 225 KVA and additional breaker for PDU and addition load on each circuit. Changes has been cloud delta 2. Plan check for power and energy. Project site is an existing commercial high-rise building. Project scope is the installation of a new 750-kVA UPS and distribution equipment and a tenant improvement to the 14th floor. Total lighting area = 8,875 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62776	17041-30000-46516	6086 W COMEY AVE	90034	10	123B173   299	5065012029	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Issued	12/28/2017 12:00:00 AM	ADDRESS	34.03516	-118.37692	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 3,303 sq. ft.Note: Building application has been generated under 17016-30000-36461	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62777	11041-20000-16434	7133 W HAWTHORN AVE	90046	4	147B181   345	5548008014	R3-1	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Public Safety Only			08/04/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.09988	-118.34596	New fire alarm for an apparment Bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62778	19041-20001-49677	16800 W ADLON ROAD	91436	5	165B133   441	2291011023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Issued	12/06/2019 12:00:00 AM	ADDRESS	34.14661	-118.49895	Revision to approved plans.  Change of module type, reduction of system size: system is now 9.28 kW DC with (29) modules and 7.6 kW rated inverter and 9.8 kWh energy storage system.  (((PV1 PLAN CHECK FOR NEW PV AND ESS. PV SYSTEM SIZE IS 9.92 KW DC/7.6 KW AC. ESS SIZE IS 9.8 KWH. SCOPE OF WORK CONSISTS OF (31) PV MODULES WITH OPTIMIZERS, A 5 KW TRANSFORMER, A 7.6 KW INVERTER, A SUB PANEL, AND A 9.8 KWH BATTERY)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62779	18041-10000-25705	2801 W SUNSET PL	90005	10	133-5A201  78	5077013036	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Apartment			07/10/2018 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	10/13/2021 12:00:00 AM	ADDRESS	34.0609	-118.2845	"PLANCHECK FOR POWER AND ENERGY. New 7-story, mixed use ""Wrap"" buildingwith only 189 Units Residential. Core and shell part of 18041-10000-03944Building Permit: 16010-10000-04209"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62780	16041-20001-16247	10100 W SANTA MONICA BLVD STE 1000	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM			PC Approved	06/17/2016 12:00:00 AM	ADDRESS	34.06191	-118.41691	[[ 6/17/16 CHANGES TO APPROVED SET OF T24 ENERGY.  DELTA 1 CHANGES ARE CLOUDED. ]]TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1623.  SCOPE TO BE PERFORMED IN THE 10 FLOOR SUITE 1000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62781	15041-10000-03561	730 W 109TH PL	90044	8	088-5A199 169	6075004009	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2015 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	33.93635	-118.28817	Plan check for PV roof mounted with 5.23kW with 21 modules and 1 inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62782	10041-10000-24305	6355 N DE SOTO AVE Bldg  3	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	04/19/2011 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.18639	-118.58869	A new 4 story 128 unit apartment building and area site lighting.  The original plan check submittal fee included some fees for building 2.   A new application was created for building 2, and the building 2 submittal fee was adjusted lower to account for building 2 fees paid on this application number.  The fire alarm plans and permit for building 3 were issued on application # 11041-10000-04061.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62783	19041-20000-00923	1750 N VINE ST 7th Floor	90028	13	148-5A189   4	5546030028	(T)(Q)C2-2-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.10311	-118.32649	TI to 7th floor of commercial office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62784	12041-10000-06319	1540 W PALOS VERDES DR NORTH BLDG P	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.7793	-118.30476	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building P. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62785	18041-20000-36457	11419 N MONTALCINO WAY	91326	12	213B109   412	2701068023	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.27907	-118.58671	Plan check for the addition of (3) Tesla PowerWalls to an existing roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62786	11041-10000-17518	1250 N CAPRI DR	90049	11	129B133    73	4407014005	A1-1XL, R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	PIN	34.04999474	-118.49995246	T.I.  At the Riviera Country Club:  Replacing the incandscent light fixtures with flourescent fixtures.  Plan check is for energy only. Permit is for 26 units.  All existing branch circuits will be used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62787	15041-10000-18612	8401 N LAUREL CANYON BLVD	91352	6	192B165   345	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM			PC Info Complete	07/20/2015 12:00:00 AM	ADDRESS	34.22336	-118.39661	TI TO AN EXISTING RESTAURANT.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOE ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 2500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62788	14041-20000-30962	9028 N ILEX AVE	91352	6	195B169   116	2631028013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.23329	-118.3888	pv1install roof mounted pv system sized 3.6kw interconnected with msp.(17) hyundai m-250 modules(17) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62789	18041-20000-09786	9400 N MASON AVE	91311	12	198B109    68	2748022048	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.2413	-118.57962	Plan check for Title 24 only. Project site is a new storage canopy. Project scope is lighting. Total lighting area = 3,516 sq. ft.Note: Building permit has been issued under 16010-20000-02965	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62790	15041-20000-43118	5757 W CENTURY BLVD STE 460	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Info Complete	12/21/2015 12:00:00 AM	ADDRESS	33.9457	-118.38274	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON SUITE 460 (CONFERENCE SPACE). SCOPE INCLUDES ADDING NEW LIGHTING TO SUITE 460. TOTAL AFFECTED AREA IS 129 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62791	17041-10000-28566	1247 W 30TH ST	90007	9	120B197   247	5055010040	(Q)R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.02754	-118.29025	Replace existing fire alarm control panel to a new ones, all notification devices are existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62792	19041-20000-53138	110 E 9TH ST 3rd Floor	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	Installation of track lighting in (E) commercial spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62793	18041-20001-32503	8420 N BALBOA BLVD ste 114	91406	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Issued	07/16/2019 12:00:00 AM	ADDRESS	34.22384	-118.50243	7/16/19changes to an approved set of plans.  changes to reflect field conditions and addition of equipment.  ((((first time tenant.  plan check for power and energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62794	12041-20000-14458	1308 S ABBOT KINNEY BLVD	90291	11	108B145  1283	4238004015	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	07/09/2012 12:00:00 AM	ADDRESS	33.99095	-118.46787	T.I. to existing building.  Install genera/emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62795	19041-20001-45044	17611 W HIDDEN OAKS RD	91316	5	168B129   551	2290015016	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM			PC Approved	11/15/2019 12:00:00 AM	PIN	34.15553827	-118.51687808	Expedited plan check fee.  PV1.  Install 34.560 kW DC / 30.506 kW AC roof mounted grid tied PV system.  (96) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62796	18041-10000-41278	4110 S AVALON BLVD	90011	9	115-5A207 498	5115002013	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2283.20	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.00879	-118.26507	PLAN CHECK FOR FIRE ALARM SYSTEM CONSTITING OF ONE FIRE ALARM PANEL AND 8 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62797	18041-10000-21850	3831 W BEVERLY BLVD	90004	13	138B197   294	5520019018	C2-1	Central	Wilshire	Wilshire Center-Koreatown		1926.20	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			PC Approved	06/14/2018 12:00:00 AM	ADDRESS	34.0765	-118.29271	TENANT IMPROVEMENT OF EXISTING RESTAURANT TO CONVERT RESTROOM TO STORAGE ROOM. TITLE 24 ENERGY ONLY. BLDG PERMIT # 18016-10000-17074	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62798	16041-10003-34971	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.06086	-118.27891	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE THE RELOCATION OF GENERATOR(DATA SHEET AND LOAD CALCULATIONS) AND CONDUCTOR ROUTING, CONDUCTOR ROUTING TO FIREPUMP, CONDUCTOR RE-SIZING, AND FAULT CURRENT/OVERCURRENT PROTECTION UPGRADE. CHANGES UNDER DELTA 3 ONLY. PC FOR POWER ONLY TO AN EXISTING HISTORICAL BUILDING. SCOPE INCLUDES ONE NEW FIRE PUMP, ONE NEW EMERGENCY GENERATOR, NEW DISTRIBUTION PANELS, AND NEW CIRCUITS. THIS PERMIT ALSO INCLUDED ALL NEW EQUIPMENTS SHOWN UNDER PLAN CHECK #16041-10001-34971	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62799	19041-10000-05336	23004 W ROSCOE BLVD	91304	12	192B097   487	2014008900	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.21913	-118.62807	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62800	12041-10000-12928	5850 W HOLLYWOOD BLVD	90028	13	148-5A191 168	5545004006	C2-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	ADDRESS	34.10149	-118.31709	Permit is for ONE BRANCH CIRCUIT per Applicant. Plan check for energy only. ADA restroom. 87sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62801	19041-10001-07593	22304 W MOBILE ST	91303	3	180B101   636	2139025017	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM			PC Approved	03/15/2019 12:00:00 AM	ADDRESS	34.1882	-118.61203	EXPEDITE PER APPLICANT REQUEST (((((PV1.PLAN CHECK FOR A NEW ROOFTOP SOLAR SYSTEM WITH 2 LG CHEM RESU10H 9.8KWH BATTRIES. PV SYSTEM CONSIST OF 27 MODULES (PANASONIC VBHN330SA16), 27 OPTIMIZERS (SE P400) AND 1 CENTRAL INVERTER (SE7600A-US). SYSTEM SIZE IS 8.91KWdc AND 7.6KWac)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62802	14041-10000-24958	14119 W BURTON ST	91402	6	192B153   869	2212020017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/28/2014 12:00:00 AM	ADDRESS	34.22077	-118.44064	PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62803	12041-10000-00393	11801 N ZELZAH AVE	91344	12	216B125   362	2601031031	RE40-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North, Porter Ranch	YES	1066.43, 1081.03	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2012 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.28668	-118.52691	Plan check 10.1KW roof mounted photovoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62804	19041-10000-41516	733 N KINGS ROAD 1-189	90069	5	141B173   318	5528002019	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.0845	-118.37197	Design build: Energy plan check for a fitness room and patio T.I located in an apartment building. Scope includes new lighting and equipment with a total lighting area of 4,451-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62805	19041-10000-23107	10434 N SEPULVEDA BLVD A2B	91345	7	207B145   700	2649019033	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Issued	06/25/2019 12:00:00 AM	ADDRESS	34.26038	-118.46701	T-24 PLAN CHECK FOR A TI TO A CHANGE OF USE FROM (E) RETAIL TO NAIL SALON. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1711 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62806	16041-10000-38739	1888 S CENTURY PARK EAST 6th & 7th-flr	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.06104	-118.41402	T.I. to entire 6th floor and stairwell on 7th floor of existing commercial office highrise building.  One new 45 kVA transformer and two new subpanels.  New lighting and receptacles.  Total area = 15,022 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62807	16041-20001-45040	7816 S BERGER AVE	90293	11	099B153    46	4114002021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	33.96517	-118.43245	12/28/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the distribution equipment. *****Previous Work Description*****Plan check for power only. Upgrade service to 600A for SFD. Refeed existing distribtion. Replace gym panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62808	18041-20000-33283	17247 W WEDDINGTON ST	91316	5	171B133   772	2258005011	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.16698	-118.50915	PV1.  Install 12.24 kW roof mounted grid tied PV system.  (34) AC modules.  Derating of main breaker to 175A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62809	16041-20000-40957	10260 ANGEL LANE	91331	7	204B165   424	2537004034	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.257211	-118.40466326	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62810	18041-20000-21370	685 S LUCAS AVE	90017	1	130-5A207 152	5143020022	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.05182	-118.26578	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62811	16041-10001-02243	5353 W PICO BLVD	90019	10	129B177   948	5085033017	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.04858	-118.35493	CHANGES TO APPROVED SET OF PLANS NOTED DELTA 1 ON PLANS. CHANGES INCLUDE ADDITION OF HALLWAY PART OF SCOPE OF WORK. PROVIDE NEW LIGHTING AND UPDATED T24 DOCUMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62812	17041-10000-03918	10250 W SANTA MONICA BLVD # 1865	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Sugarfina"" Ste. 1865.  Install new Xrfmr, and  panel, total area 718 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62813	16041-20001-17291	18451 W SUNNY LANE CT	91356	3	171B125   199	2161021048	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM			PC Approved	05/23/2016 12:00:00 AM	ADDRESS	34.16716	-118.53531	expedite per customerPV1.  Install 11.1 kW roof-mounted PV system.  (38) modules with (2) central transformerless inverters rated at 7 kW and 3.8 kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62814	15041-20000-09153	8129 N AURA AVE	91335	3	189B117    92	2105018002	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Issued	03/27/2015 12:00:00 AM	ADDRESS	34.21787	-118.55479	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62815	12041-10000-15298	1425 N MONACO DR	90272	11	132B133   265	4425019030	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2012 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	07/06/2012 12:00:00 AM	ADDRESS	34.05578	-118.50114	UPGRADE SERVICE 800A   TO SUPPLY ADDITIONAL LODAS- NEW GYM/EQUIPMENT AND GARDEN POND	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62816	14041-20000-33429	3520 W CRESTMONT AVE	90026	13	145-5A203 311	5429020019	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.09268	-118.27471	Roof mounted PV system with total system size 3.8 KWac.Note: solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62817	11041-10000-14007	338 N LA BREA AVE	90036	5	138B181   212	5525032004	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM			PC Approved	08/29/2011 12:00:00 AM	ADDRESS	34.07737	-118.34384	Converting two retail spaces into one yoga studio.  Plan check is for energy using Tailored method.  At the time of submittal, applicant did not know if this was a change of use.  Requested for energy plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62818	14041-20001-15640	17159 W ENADIA WAY	91406		183B133   172	2227021007							Electrical	Electrical	1 or 2 Family Dwelling			06/16/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.20024	-118.50764	Change from previously approved plans.  Relocate electrical equipment.  No changes in module and inverter model number.  Note: Permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****New roof mounted PV system 300W Optimizers and 3.8KW transformerless inverter.  Total system size 4.6KWdc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62819	16041-20002-04338	1207 E ADAMS BLVD	90011	9	118-5A211 348	5119022003	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.01763	-118.25209	[[[6/8/16 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO THE LOCATION OF THE DC DISCONNECT, SOLAR METER AND INVERTER.]]PV1.  Install 5.2 kW rooftop mounted PV system.  Applicant design set plans.  (1) SolarEdge SE5000A-US transformerless inverter with power optimizers and (20) Q.PRO BFR-G4-260 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62820	18041-10000-47589	6233 N VARIEL AVE	91367	3	177B105    18	2149001027	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Apartment			01/02/2019 12:00:00 AM	02/14/2020 12:00:00 AM		Permit Finaled	07/11/2022 12:00:00 AM	ADDRESS	34.18397	-118.59309	New 8 story, 336 Unit,  assisted living facility over 1 level subterranean parking.Plan check for power & energy. Building Permit: 18010-10000-04241	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62821	15041-10000-10815	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.16603	-118.52861	NEW FIRE ALARM SYSTEM 59 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62822	12041-10000-07394	1780 S LA CIENEGA BLVD	90035	10	126B173   133	5066006011	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.0449	-118.37657	NEW PIZZA HUT RESTAURANT. PLAN CHECK FOR POWER & ENERGY. (Per Applicant's Request)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62823	19041-10000-29731	13400 S ESTRELLA AVE	90248	15	078B201    76	6132004014	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	33.91053	-118.28596	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62824	15041-20001-31676	10831 N AQUEDUCT AVE	91344	12	207B141   131	2662021014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.26747	-118.47408	Expedite per applicant request[[[[[[[[[[[[[[Plan check for PV roof mounted sytem. System size: 7.6kW with 31 modules and 1 inverter(7.6kW)]]]]]]]]]]]]]]]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62825	13041-20000-17777	6939 N VAN NUYS BLVD	91405	6	183B149   466	2219026066	C2-1L, P-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	10/04/2013 12:00:00 AM	ADDRESS	34.19667	-118.44898	FULL PLAN CHECK FOR POWER AND ENERGY. NEW 800A SERVICE ON COMMERCIAL FUTURE BANQUET HALL. TOTAL SQRFT INDOOR 14960. TOTAL SQRTFT OUTDOOR 855.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62826	18041-20000-40063	3333 S BARBYDELL DR	90064	5	123B165   782	4316024019	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.03228	-118.40384	PV1.  Install roof mounted PV system sized 12.2kW AC interconnected with MSP.$17.05 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62827	17041-20000-09735	4715 N OLSON ST	90041	14	160-5A223 375	5685019024	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/01/2017 12:00:00 AM	ADDRESS	34.13236	-118.2085	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.8KW.   PV SIMPLIFIED STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62828	13041-10000-04221	22914 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.18625	-118.62585	Existing commercial sale buidling. Plan check for power and energy. Existing panels but relocating 1 panel. 29,111 sqrft. A varience will be filed before the plans are approved for the fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62829	17041-20000-39720	2504 N SILVER LAKE TER	90039	5	148-5A207  17	5439018001	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Closed	04/02/2022 12:00:00 AM	ADDRESS	34.10326	-118.26181	addition of (2) tesla power walls.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62830	15041-10000-13565	11301 W PICO BLVD	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Expired	07/26/2017 12:00:00 AM	ADDRESS	34.03517	-118.43924	PLAN CHECK FOR ENERGY ONLY FOR EXISTING 44,000 SQRFT BEST BUY RETAIL STORE TAILORED METHOD. Less than 400A connected load. Fees are under inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62831	14041-10000-12941	1375 W ADAMS BLVD A-C	90007	8	123B197   881	5055004026	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM			Corrections Issued	05/14/2014 12:00:00 AM	ADDRESS	34.03295	-118.29107	TENANT IMPROVEMENT FOR ICE CREAM SHOP.  NEW INTERIOR PARTITIONS.  EQUIPMENT AND FINISHES. (1,516S.F.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62832	13041-10000-18525	6081 W CENTER DR #113-119	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			Ready to Issue	11/08/2013 12:00:00 AM	ADDRESS	33.97811	-118.39245	PANEL CHANGE IN DWP ROOM, RELOCATING LOADS TO EXISTING PANEL . FEEDERS FOR FUTURE TENANT. SERVICE SIZED OVER 1600A, SECTION SIZE 1600A. APPROVAL PENDING UTILITY 12 MONTH PEAK READING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62833	10041-10000-21498	1718 N VINE ST	90028	13	148-5A189  82	5546030027	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM	10/28/2010 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.10224	-118.32648	two story comercial with roof new fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62834	14041-10000-11740	265 W WORLD WAY	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			PC Approved	05/02/2014 12:00:00 AM	PIN	33.94447227	-118.40494652	REMODEL OF EXISTING DWP BUILDING (UNMANED, EQUIPMENT ONLY) : new luminaires in the electrical and control rooms; new outside luminaires; Plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62835	12041-20000-21617	14000 W RIVERSIDE DR	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Closed	10/24/2012 12:00:00 AM	ADDRESS	34.15735	-118.43783	T.I. to an existing retail space.  Change to lighting and HVAC system.  Load is less than 400Amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62836	15041-20002-15157	19791 W BAHAMA ST	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.23359	-118.5643	Revisions to approved plans.  Changes to lighting design.  (((Title 24. TI to existing warehouse building with offices. Plan check for energy only including including emergency. Total sqft. 16,352)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62837	16041-40000-42849	11300 W OLYMPIC BLVD STE#770	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.03792	-118.44134	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 940 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62838	13041-20000-34770	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM			PC Approved	12/24/2013 12:00:00 AM	PIN	34.12750533	-118.21285206	Change to lighting, 35,362 sq. ft. of lighting.  Existing circuits, Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62839	16041-20000-24561	2191 W 28TH ST	90018	10	123B189   978	5052029013	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.03005	-118.31469	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.6KW INERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62840	13041-10002-09317	4030 S WESTERN AVE	90062	8	114B193   331	5021008030	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.01061	-118.30872	Changes for previously approved plan #13041-1001-09317. Changes to the clouded area.FULL PLAN CHECK POWER AND ENERGY FOR EXISTING SPACE (RALPHS) TO BE SUBDIVIDED FOR THREE NEW TENANTS. 600A SERVICE. 25543 sqrft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62841	10041-10000-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Addition and alteration to the TBIT.  The Core.  Full electrical and energy.  Variance was filed to separate the electrical and fire life safety plan checks and permits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62842	15041-20000-15730	8454 N CASABA AVE	91306	3	192B113   257	2781022005	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.22396	-118.57639	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (30) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62843	19041-10000-28188	15035 W DEL GADO DR	91403	4	165A147    46	2277001029	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2019 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.14799	-118.46164	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KVA PV1 SYSTEM AND ESS CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 28 MODULES USING P320 OPTIMIZERS AND TESLA POWERWALL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62844	17041-10000-09064	10706 S JUNIPER ST	90059	15	090A217   548	6068006016	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	33.93873	-118.23246	PV , INSTALLATION OF A 3.920 KWdc / 3.00KWac ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: CANADIAN SOLAR (1) INVERTER: SOLAREDGE SE3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62845	13041-10000-21153	12652 W VILLAGE LANE bldg #11	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #11	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62846	14041-20001-01440	672 1/2 E INDIANA AVE	90291	11	111B145  1312	4239008019	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	33.99723	-118.46715	(((EXPEDITE FEES)))PV1 TWO FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC. THIS IS SECOND SYSTEM TO BE ON SAME INTERCONNECTION AS THE ORIGINAL ADDRESS RANGE. INTERCONNECTION IS 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62847	14041-10001-06143	1173 S HAYWORTH AVE	90035	5	132B173  1225	5087026015	R2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.05404	-118.36705	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 5.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.6-OUTD-S-US-Z-A(21) CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62848	10041-20001-18321	440 S VERMONT AVE #111	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM	12/27/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	Changes from previously plans.  Changes include lighting and outlets.  Plan check for energy only.*****First time tenant to a new building (Cell Phone Village).  Plan check for energy and power. Suite #111*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62849	14041-20000-06543	5701 N LASAINE AVE	91316	5	174B133   380	2254019014	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Expired	04/19/2016 12:00:00 AM	ADDRESS	34.17425	-118.51056	PV1 TRANSFORMERLESS SYSTEM WITH SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62850	18041-10000-11787	1710-1712 W PACIFIC COAST HWY	90717	15	033B193    51	7553018023	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	33.7893	-118.30798	PC FOR Tenant Improvement to existing Restaurant FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS  (interior and exterior). TOTAL  AFFECTED AREA 7355 SQ.FT.B#18016-10000-09842	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62851	11041-20000-21614	20725 W PRAIRIE ST	91311	12	198B109    72	2748002037	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	10/18/2011 12:00:00 AM	ADDRESS	34.24102	-118.58508	T.I./ ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62852	16041-20000-24972	8547 N KEOKUK AVE	91306	3	192B113    83	2781013015	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Expired	08/23/2018 12:00:00 AM	ADDRESS	34.22587	-118.57408	Plan check for PV roof mounted system. System size: 7.6kW with 40 modules and 1 inverter(7.6kW) Standard plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62853	15041-20001-38206	5135 N BLUEBELL AVE	91607	2	171B161   655	2357001003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM			Reviewed by Supervisor	11/25/2015 12:00:00 AM	ADDRESS	34.164	-118.41064	**EXPEDITE FEE**PV1, roof mounted solar panel, 11.13kW DC system (42)modules #KU2656ZPA, (1)inverter:#SE10000A-US-ZB-U	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62854	13041-10000-35763	2317 S SCARFF ST 1-4	90007	1	123A203    41	5124012008	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Apartment			12/23/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	07/21/2014 12:00:00 AM	ADDRESS	34.03291	-118.28021	FA 1 PANEL AND 26 DEVICES FOR APT. R2 4 unit qapartment over subterranean parking garage, and related sitework.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62855	11041-10000-12983	11150 W SANTA MONICA BLVD SUITE-1425	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			No Progress	06/22/2011 12:00:00 AM	ADDRESS	34.04704	-118.44563	TI TO AN EXISTING HIGH-RISE OFFICE BUILDING ON THE 14TH FLOOR.  PLAN CHECK IS FOR ENERGY WITH EMERGENCY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62856	17041-20002-21623	421 E 116TH ST	90061	15	084B205  1548	6083006029	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Issued	04/17/2018 12:00:00 AM	ADDRESS	33.92928	-118.26569	4/10/2018changes to an approved set of plans.  changes to add disconnect and feeder tag 5.(((PC FOR ROOF MOUNTED PV SYSTEM WITH STORAGE BATTERY. PV SYSTEM SIZE 3.0 KW ACTOTAL OF 8 PV MODULES WITH OPTIMIZERSBATTERY IS TESLA POWERWALL 2.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62857	11041-20000-03625	3415 S SEPULVEDA BLVD #645-#650	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	03/23/2011 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	"T.I. to a high rise building.  Install general/emergency lighting.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62858	18041-10001-47666	21425 W DEVONSHIRE ST	91311	12	204B105   860	2722007052	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.2574	-118.5981	CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES UNDER CLOUDED AREAS. SCOPE OF WORK INCLUDES RELOCATION OF SWITCHES AND ADDITION OF LEGENDS. ____________________DESIGN BUILT, PLAN CHECK FOR TITLE 24 ONLY T.I TO ART SCHOOL. SCOPE INCLUDES 1930 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62859	11041-20000-04148	4553 S GLENCOE AVE #390	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	33.98415	-118.43328	energy plan check # 390	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62860	10041-20000-14998	920 W DOWNEY WAY #210	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM			PC Info Complete	08/03/2010 12:00:00 AM	ADDRESS	34.02063	-118.28879	Plan check T-24 energy mandatory measures only for Lab 210 at USC Biegler Hall. All lighting fixtures are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62861	19041-10000-05756	15640 W ROXFORD ST	91342	7	225B145   322	2501004026	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	34.31083	-118.47188	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID FIXTURES WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62862	10041-10003-03249	7333 W WORLD WAY 4th FL	90045	11	090B161    67	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			02/02/2011 12:00:00 AM	02/02/2011 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	PIN	33.94534804	-118.41786236	TI for offices on the 4th floor of the existing LAWA Admin Building.((((((((((  Conduit run has changed.  Originally went under the footing to exit the building but has been changed to go through the wall  because there is no methane problem.   )))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62863	12041-10002-07640	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions to permitted set of plans. Changes to show that LAWA is providing distribution, switchboards, and panels to tenant (DELTA), which was previously under the scope of DELTA.  All loads are approved on #12041-10001-22730. Plan check power for LAX Terminal 5 Primary switchgear and distribution (infracture upgrade). New equipment, switchboards, and panels. Existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62864	12041-10000-13430	18855 W VICTORY BLVD	91335	3	180B121   391	2127001014	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			06/11/2012 12:00:00 AM			PC Approved	06/11/2012 12:00:00 AM	ADDRESS	34.18675	-118.54436	Plan check for energy and emergency lighting. 4430 conditioned sqft. Occupant load is under 100. Low rise with emergency generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62865	14041-10000-18023	12196 W VENTURA BLVD	91604	2	162B165   214	2369004039	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.14305	-118.39841	Title 24 plan check only.  Total area = 555 sq. ft.Kitchen remodeling for existing restaraunt space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62866	18041-10000-22315	6855 S LA CIENEGA BLVD	90045	11	102B173   135	4103001009	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	02/03/2020 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	33.97564	-118.37051	NEW SMART & FINAL GROCERY MARKET.  FULL PLAN CHECK FOR POWER AND ENERGY. BUILDING PERMIT NUMBER 18014-10000-03346 TOTAL NEW CONNECTED LOAD 1535A CONNECTED TO MSBFIRST TI CONNECTED TO EXISTING MSB DISTRIBUTION BOARD.  ALL OTHER SPACES ARE EMPTY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62867	19041-10001-04390	3790 W WILSHIRE BLVD	90010		132B193    69	5093006030							Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.06153	-118.30861	DELTA 4 CHANGES TO AN APPROVED SET. CHANGES TO EM LIGHTS THROUGH OUT BASEMENT AREA AND REMOVE HALL-WAY AREA FROM SCOPE OF WORK. ((((PLAN CHECK FOR TITLE 24, ENERGY ONLY. LIGHTING AND POWER RENOVATION FOR (3) BAR AREAS OF EXISTING HISTORICAL BUILDING. TOTAL SQUARE FOOTAGE = 7362 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62868	19041-20000-10649	6420 W WILSHIRE BLVD	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	09/19/2021 12:00:00 AM	ADDRESS	34.06365	-118.36922	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indorr/outdoor energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62869	18041-10000-01510	2270 S HARVARD BLVD	90018	8	123B193   422	5058018029	[Q]RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.03422	-118.30632	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 11400 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62870	16041-10000-39176	3150 W WILSHIRE BLVD STE 100	90010	10	132B197    39	5077010025	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.06163	-118.29086	Plan check for power and energy for  restaruant T.I. 800A Distribution equipment. Total area: 5,776 sq ft. Connected to an existing 4000A distribution board - Per supervisor(Mehdi Zandi) Restaurant is ok to use inverter system to supply emergency power to to emergency lighting and exit signs.(restaurant is located in high rise building)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62871	15041-20000-43922	19530 W PRAIRIE ST	91324	12	198B117   253	2761035014	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.23892	-118.56107	Plan check for new common area in a condo complex. Plan check for energy only. Adding new lighting and receptacles. Total sqft. 647 (cond) + 1818 (uncond).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62872	16041-10001-39934	555 N ROSSMORE AVE	90004	4	141B185   977	5523009011	R4-2	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.0805	-118.32738	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include revising single line diagram to reflect as built. Revising the methane double pull section and update the AIC values for existing electrical equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62873	13041-10000-32803	630 W HARRY BRIDGES BLVD Main Bldg	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	33.77068	-118.26868	NEW FIRE ALARM SYSTEM FOR PORT OF LA - TRA-PAC-ADMIN BUILDING. TOTAL AREA IN SCOPE OF WORK PROJECTED TO BE 25,480 SQ FT, WITH 169 DEVICES, (1) FIRE ALARM CONTROL PANEL. 4-STORY ( + ROOF ), SPRINKLERED BUILDING.EXISTING PC# UNDER: 12041-10001-18057	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62874	19041-10000-48275	107 N ST ANDREWS PL	90004	4	138B193   987	5516021007	R2-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.07342	-118.31151	NEW ROOF MOUNTED 7.08KW PV SYSTEM WITH 24 PV PANELS @295W. AND 24 OPTIMIZER (320W) AND ONE CENTERAL INVERTER @ 5000W ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62875	10041-20000-09081	1816 W 6TH ST	90057	1	133-5A205 350	5142008014	C2-2	Central	Westlake		YES	2089.02	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM			PC Approved	05/14/2010 12:00:00 AM	ADDRESS	34.0581	-118.27219		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62876	14041-10000-05922	1000 W ELYSIAN PARK AVE LEVEL 5	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	Dodger Stadium level 5 bar/concession stand remodel.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62877	17041-10001-10410	11641 N CORBIN AVE	91326	12	213B113   277	2701057900	PF-1XL	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.28132	-118.5698	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62878	18041-20001-42465	2211 W SUNSET BLVD	90026	13	139-5A207  80	5402031021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1956.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.07778	-118.26564	Supplemental Plan check only for Title 24 only in existing space Yogurt Shop T.I. Total area: 650 sq ft. inspection paid for under E#18041-20000-42465B#18016-20000-34387	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62879	14041-20001-34876	3410 N LA SOMBRA DR	90068	4	159B181   402	5579025005	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM			PC Approved	02/06/2015 12:00:00 AM	ADDRESS	34.13151	-118.34095	Plan check fee is $0.00 due to State Senate Bill SB-1222Change of inverter model from 5kW model to 6kW.  (((Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters and (53) modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62880	16041-20002-45606	1020 N VERMONT AVE	90029	13	144B197   761	5539003024	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.09057	-118.2915	Revisions to approved set of plans.  Miscellaneous feeder detail revisions/SLD changes.  Approval for clouded items on sheets E-1 and E-6 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62881	16041-30000-35537	14721 W CALIFA ST	91411	4	177A149   147	2244009026	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.1777	-118.45431	Plan check for power and Title 24.  Installation of 2 new transformers and 7 new subpanels to provide power for future TI of existing one story office building.  6 of the subpanels have no load.  The last subpanel has only two branch circuits for electrical room lighting and exhaust fan.  Scope of work is limited to electrical room only.  Title 24 area = 156 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62882	17041-20000-43992	1400 N CAHUENGA BLVD	90028	13	147A187   244	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Closed	02/20/2021 12:00:00 AM	ADDRESS	34.09641	-118.32933	Temp power for construction of hotel.  600A 480Y/277V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62883	19041-20000-43722	1332 S HARBOR BLVD	90731	15	012B201    16	7440031904	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM	03/16/2023 12:00:00 AM		Issued	03/16/2023 12:00:00 AM	ADDRESS	33.73281	-118.27675	FULL PLAN CHECK FOR POWER AND ENERGY ONLY. CORE AND SHELL. SCOPE OF WORK INLCUDES NEW 5000 AMP, 480/277V, 3PH SERVICE WITH NEW PANELS, CIRCUITS AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62884	19041-20000-44594	11600 W PICO BLVD	90064	11	123B153   652	4260033045	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.03227	-118.44393	Plan check for new fire alarm system, Total new fire alarm devices: 41 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62885	17041-10000-13052	4380 W ADAMS BLVD	90018	10	123B185   726	5051007001	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.03237	-118.33439	PC for energy only, Outdoor Title-24.  Removing HID fixtures and replacing with New LED. area: 18,575.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62886	19041-10000-32986	313 E GRAND BLVD	90291	11	108B145  1786	4238014902	C2-1-O, P-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	33.9883	-118.46955	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62887	14041-20001-35772	5000 S MAIN ST	90011	9	111A205   300	5109004053	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	PIN	33.99720157	-118.27357014	09/04/2015 Changes to an approved set of plans. Changes include the replacement of the PV module from one model to Candaian Solar CS6x 305P. Module wattage has increased. Module count and inverter type has remained the same. Changes have been clouded and marked as Delta 2 and 4. Permit to be pulled on master application.*****Previous Work Description*****PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PC FOR PV2 COMMERCIAL ROOFTOP SOLAR. 55.2KW DC USING 4 INVERTERS. LOAD CENTER AND NET METER WITH MAIN SERVICE. TRANSFORMERLESS INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62888	13041-10001-20678	10425 N COLUMBUS AVE	91345	7	204B145    26	2649019026	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	10/30/2013 12:00:00 AM	ADDRESS	34.25989	-118.46519	SUPPLEMENTAL PLAN CHECK TO 13041-10000-20678. CHANGE OF ROOF LAYOUT.PV1 4.32KW 240V MICROINV 2STORY. STD. ROOFMOUNT.[( 20) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62889	17041-10000-28704	11141 N TAMPA AVE FIRST FLR	91326	12	210B117    35	2701004014	(Q)C2-1, C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.27342	-118.55714	PC for T24 for office space TI for first floor. Total affected area of 7000sqft. Installing new lights. Building# 16016-20000-21196.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62890	18041-10001-21753	11755 W OLYMPIC BLVD	90064	11	123B149   426	4260010020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.03383	-118.44921	PLAN CHECK FOR TITLE 24 ONLY FOR - RETROKIT 399 FLUORESCENT FIXTURES TO LED ENGERY SAVING. - TOTAL AFFECTED AREA = 12384 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62891	19041-10000-32887	640 S MAIN ST	90014	14	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM			PC Info Complete	12/23/2019 12:00:00 AM	ADDRESS	34.04429	-118.2507	FULL PC FOR Renovation of (E) 159,800sf 14 story NON-DUCTILE CONCRETE hotel building. 1) Change of Use of a portion of the building - (N) use to include 299 hotel guestrooms , 301 apartments. 2) (N) Assembly occupancy with bar and pool on roof , 3) (N) elevator tower 4) Structural alteration. service size 2500A,480/277V, 3Ph, 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62892	13041-20000-19896	11047 N DE SOTO AVE	91311	12	210B109    68	2706001033	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.01	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Approved	08/03/2013 12:00:00 AM	ADDRESS	34.27142	-118.58911	New standalone locker room for a school athletic field with outdoor lighting for the parking lot.  Load is less than 400 amps.  Plan check only for T-24.  Permit fees are under inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62893	19041-10000-51854	5148 N DAHLIA DR	90041	14	163-5A227 312	5669012008	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.14099	-118.19961	Installation of roof-mounted Tesla Energy Battery to an existing  solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling. PV solar permit obtained under 19041-90000-46922	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62894	15041-10007-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.02201	-118.28947	REVISIONS TO PERMITTED SET OF PLANS FOR lABORATORY BUILDING:LEVEL 3 AREA A L REGIONS 1 & 3 ;  LEVEL 3 AREA BNEW BRANCH CIRCUITS ADDED TO SUPLY NEW LABORATORY EQUIPMENT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62895	16041-20002-04648	4542 N SYLMAR AVE	91423	4	168A151   189	2265016014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM			PC Approved	06/09/2016 12:00:00 AM	ADDRESS	34.15423	-118.44637	06-09-16 Changes to an approved set of plans. Changes include up size PV breaker to 40A and 40A fuse disconnect and wire size to #8AWG and update grounding diagram. {{{{Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (24) modules. Standard plan is not being used.}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62896	17041-10001-39640	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	03/15/2019 12:00:00 AM		Permit Finaled	08/23/2021 12:00:00 AM	ADDRESS	33.94571	-118.38857	DELTA 3 Change to approved set of plans. Major changes to the single line diagram and floor plans. Changes include adding a new 5000A service/distribution board, new panels,  and circuits. Refeeding existing equipment to new service, revising floor plans, and load calculations. B#16016-10000-29872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62897	17041-10000-14433	3051 E WASHINGTON BLVD	90023	14	117A223     2	5169019009	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Issued	05/02/2017 12:00:00 AM	ADDRESS	34.01631	-118.21332	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new LED ones.Area: 45900 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62898	11041-20000-15214	19809 W PRAIRIE ST #100	91311	12	198B113   115	2761040023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM	10/21/2011 12:00:00 AM		Permit Finaled	05/01/2012 12:00:00 AM	ADDRESS	34.23925	-118.56529	PLAN CHECK POWER AND ENERGY FOR OFFICE TI #100	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62899	16041-10000-11792	12208 W RIVERSIDE DR	91607	2	168B165   552	2356036035	RD1.5-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.15736	-118.399	NEW FIRE ALARM SYSTEM 72 DEVICES AND 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62900	16041-20000-15172	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.2215	-118.42999	PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORTS. 69,142 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62901	14041-20000-04546	6111 N TOPANGA CANYON BLVD	91367	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Approved	02/19/2014 12:00:00 AM	ADDRESS	34.18157	-118.60615	honda sign energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62902	14041-20000-31803	22853 W COVELLO ST	91307	12	186B097   339	2021012022	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.20736	-118.62525	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING SINGLE TRANSFORMERLESS INVERTER.  NONSTANDARD PLAN. SYSTEM USES POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62903	16041-10000-26298	12950 W VICTORY BLVD	91606	2	180B161  1112	2331032184	[Q]C1.5-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Closed	11/09/2016 12:00:00 AM	ADDRESS	34.18651	-118.41539	Plan check for T-24 only.  Remove exterior lights of HID fixtures and replace with new LED fixtures. Total affected area: 30,082 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62904	14041-20000-04701	2600 N SUMMITRIDGE DR	90210	4	156B157   371	4386013005	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.12137	-118.42066	Upsize the emergency generator to 150KW, replace 800A  main switchboard.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62905	16041-20000-35605	5900 N TEXHOMA AVE	91316	5	177B129   861	2254005029	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.17762	-118.51565	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (30) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62906	18041-10000-17408	21215 W SHERMAN WAY	91303	3	183B105    66	2112023010	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.2012	-118.59488	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62907	18041-10000-01795	2471 N BEACHWOOD DR	90068	4	153A189   126	5585019024	RD2-1XL	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Public Safety Only			01/17/2018 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.11496	-118.32169	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING FOR R2 RESIDENCE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62908	15041-10000-42256	8435 N CANOGA AVE STE B	91304	3	192B105   322	2779022078	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.22266	-118.59769	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LEDS.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 7200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62909	14041-20001-31393	9694 W OAK PASS ROAD	90210	5	153B157   128	4384007023	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.11636	-118.42855	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 22.5KW AC USING MICROINVERTERSYSTEM. USING ENPHASE M250. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62910	17041-20000-35358	2209 S SANTA FE AVE	90058	14	118-5A217 206	5167008028	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.01795	-118.23056	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 115 KW (320) NEO SOLAR POWER 360(3) SOLAR EDGE SE33.3KUS(160) P800 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62911	15041-10001-37896	219 N AVENUE 56	90042	1	151-5A227  77	5468033034	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.11057	-118.19522	EXPEDITE PER APPLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(15) SUNPOWER MODULES(1) 5KW INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62912	15041-10000-42936	1407 N TANAGER WAY	90069	4	147B169   791	5560004005	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2015 12:00:00 AM	01/24/2017 12:00:00 AM		Issued	01/24/2017 12:00:00 AM	ADDRESS	34.097	-118.3854	PC FOR POWER,  ADD ONE LEVEL HABITABLE BASEMENT AND  RENOVATION TO EXISTING SINGLE FAMILY  RESIDENCE. NEW ELECTRICAL EQUIPMENT 600AMP SWITCHGEAR, CONNECTED LOAD >400AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62913	11041-20000-10924	6100 W CENTER DR #800	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM			PC Approved	05/27/2011 12:00:00 AM	ADDRESS	33.97733	-118.3922	T.I. to existing high rise building.  Install general/emergency lighting on the partial of the 8th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62914	18041-10000-09106	216 S ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	02/23/2021 12:00:00 AM	ADDRESS	34.04645	-118.23792	PC FOR ELECTRICAL SERVICE UPGRADE FROM 400A TO 800A 480/277 3P.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62915	18041-30000-17833	6033 W CENTURY BLVD 7TH &-9TH	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	33.94572	-118.38954	PLAN CHECK FOR T24 ONLY, INSTALL NEW LIGHTINGS IN THE CORRIDOR 7TH AND 9TH FLOOR, 1337 SQ.FT OF A HIGH RISE BUILDING.((B# 18016-10000-06059))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62916	13041-10000-26030	12411 W FIELDING CIR Block 7	90094	11	105B161  1220	4211034054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/03/2013 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	33.97968	-118.40871	PLAN CHECK FOR POWER AND ENERGY.  BLOCK 7 OF PLAYA VISTA PROJECT. ELECTRICAL INSTALLATION FOR MULTI-FAMILY 4-STORY OVER PODIUM; 5 SERVICES (SERVICE 1,2,3,4,5), LOCATED IN METHAN ZONE, METHANE DESIGN LEVEL 1.  (2) GENERATORS INSTALLED. TOTAL 703 UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62917	13041-10000-13524	2938 N FINCH ST	90039	13	151-5A207  19	5437024002	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Expired	07/13/2015 12:00:00 AM	ADDRESS	34.11133	-118.26152	PV1.  Install 3.924 kW DC roof-mounted solar array on 2-story single family dwelling and interconnect into existing main service panel.  {12 modules: Sunpower SPR-327NE-WHT-D} {Transformerless inverter: Power One PVI-3.6-OUTD-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62918	18041-10000-06124	7939 N CANOGA AVE	91304	3	189B105   191	2110005014	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.21451	-118.5977	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62919	18041-20001-47172	2551 N PARK OAK DR	90068	4	153B193    62	5580022013	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.11716	-118.31338	Expedite per applicant request. Plan check for PV roof mounted  Energy Storage system , system size: 16.8kW DC, 13.6kW AC with 48 PV modules and 2 inverter(7.6kW and 6.0kW), Battery Sonnen ECO 10(10kWh).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62920	19041-20000-50640	3054 S VICTORIA AVE	90016	10	120B185   809	5050031057	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	05/05/2020 12:00:00 AM	ADDRESS	34.02594	-118.33621	New panel, power, and lighting for commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62921	16041-10000-01698	1020 N VERMONT AVE	90029	13	144B197   761	5539003024	C2-1D	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM			PC Info Complete	03/08/2016 12:00:00 AM	ADDRESS	34.09057	-118.2915	Full plan check for a whole new power system upgrade for an assembly area (Theater building) . Scope incclude a new 1600 Am service, panels and circuits. All general lighting circuits are reconnected to a new panel. All lighting and control remain untouch.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62922	17041-10000-05832	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.05855	-118.23671	Plan check for power only in existing space install and connect telecommunicaiton rack outlets to existing remote power panels in the same room. install (84) 3 phase 60A receptacle and (4) 3 phase 30A Single Line diagram is existing and for reference only. New load has been added to 16 existing panels. newly connected load exceed 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62923	19041-10000-15941	1076 S FAIRFAX AVE	90019	10	132B177   965	5086001042	C2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.05607	-118.36462	Energy plan check for a restaurant T.I located in a single building. Scope includes new lighting and equipment with a total area of 3189-SQ FT. Note. portion of permit fee is paid under 18041-90000-45535.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62924	13041-10000-30849	8444 N PINELAKE DR	91304	12	192B093   145	2005015004	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/27/2013 12:00:00 AM	ADDRESS	34.22243	-118.63739	PV1, Install 9.25 kW DC roof-mounted solar array, interconnect with service panel. Multiple transformerless inverters: Solaredge SE 3800A-US and Solaredge SE 5000A-US. 37 modules: Yingli Yl245P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62925	16041-10000-26890	3500 W SUNSET BLVD	90026	13	144A203   227	5427025009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	Yes	1959.02	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.08867	-118.2766	PC FOR ENERGY. TI TO CONVERT (E) DONUT SHOP W/KITCHEN TO A CHINESE RESTAURANT. AREA 993 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62926	13041-10000-06064	23333 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			03/07/2013 12:00:00 AM			Plans on Hold	03/15/2013 12:00:00 AM	ADDRESS	34.15724	-118.63407	cashier wouldn't take the old submittal fees for 13041-10000-03823. this is payment for submittal since the original submittal check bounced. mt 3/7/2013 pc for power and energy. Non-structural interior tenant improvement in existing medical office, including:  new non-bearing partitions to create new office, storage room and restroom.  No change of use.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62927	10041-10000-05357	6743 W HOLLYWOOD BLVD	90028	13	148-5A185 110	5547010012	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM			PC Info Complete	03/24/2010 12:00:00 AM	ADDRESS	34.10172	-118.33723	TI in an existing commercial space. Plan Check is for title-24 Energy calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62928	17041-10000-30099	8034 N MCLAREN AVE	91304	12	189B097   288	2014001016	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.21651	-118.62434	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE = 3KVA SYSTEM CONSISNTING OF 1 CENTRAL INVERTER(SE3000-US) WITH 11 MODULES(CANADIAN SOLAR-CS6K-275)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62929	15041-10001-33830	3753 N MONTEREY ROAD	90032	14	144A229    42	5302028026	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.09041	-118.18827	PROVIDING PLAN CHECK FOR PV SYSTEM. SYSTEM IS 2.5KW AC USING CENTRAL INVERTER SYSTEM WITH 8 MODULES. INTERCONNECT WITH MAIN PANEL.N EXTRA TRIP FEE COLLECTED UNDER THIS PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62930	13041-10002-30085	6238 N AURA AVE	91335	3	177B117   236	2131013010	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.18412	-118.55439	Expedited RSES plan check per applicant request.(((PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 16 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62931	16041-10000-18950	10519-10519 1/2 N SAMOA AVE	91042	7	207B197  1541	2566007033	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM	05/31/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.25996	-118.28703	PV1, INSTALL A 7.6 KW AC ROOF-MOUNTED SOLAR SYSTEM ON AN EXISTING SINGLE FAMILY HOUSE.(40) MODULES; SOLARCITY STANDARD 265W(1) INVERTER: FRONIUS PRIMO 7.6 KW	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62932	16041-10001-05604	10760 N DES MOINES AVE	91326	12	207B117   189	2728001012	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.26519	-118.55434	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 12.43 KW DCROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(38) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTER: SMA SB6000TL& 5000TL US-22>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62933	10041-10001-03289	900 S WESTGATE AVE 101-106	90049		129B145   397	4265017041	R3-1		Brentwood - Pacific Palisades				Electrical	Electrical	Apartment			11/30/2010 12:00:00 AM			PC Approved	11/30/2010 12:00:00 AM	ADDRESS	34.05068	-118.46804	DELTA 1 CHANGES TO THE APPROVED PLANS, USING DIFFERENT TYPES OF LIGHT FIXTURES IN THE GARAGE - LOBBY AREA IN A 19 UNITS APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62934	18041-20000-38435	5922 1/2 W BARTON AVE	90038	13	144B189  1076	5534027036	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.08778	-118.32315	pv2install roof mounted pv system sized 2KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62935	15041-10002-37855	189 S THE GROVE DR G-60	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	05/09/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	03/23/16Changes to an approved set of plans. All changes are made under delta 3. Changes include removing/replacing/adding lighting fixtures, and receptacles. Now using performance method for title 24 calculations.NOTE: permit pulled under PCIS#15041-10000-37855  ((((Supplemental changes on approved set: added receptacles, revised EM lighting layout, revised lighting control schematic, updated lighting specs. and panel schedule, updated T-24 form, added photometric sheet. ***T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (VINCE STORE ). SCOPE INCLUDES NEW LIGHTING, TWO NEW PANELS, AND ONE TRANSFORMER. TOTAL AREA IS 2439 SQ. FT.***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62936	18041-20000-21966	17800 W CANDIA CT	91344	12	219B129   359	2601050049	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.29744	-118.52115	Plan check for PV roof mounted system. System size: 11.025 KWac with 35 modules and 35 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62937	13041-20000-15793	817 N CHAUTAUQUA BLVD	90272	11	126B129   182	4423025029	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.04418	-118.51745	Install new rooftop PV system for an existing single family dwelling.  System uses Enphase Microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62938	15041-10001-16712	866 S TREMAINE AVE	90005	4	132B185   339	5090004017	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2015 12:00:00 AM			Verifications in Progress	07/23/2015 12:00:00 AM	ADDRESS	34.05909	-118.33638	PV 1, 45 MODULES AND 45 MICRO INVERTERS. TOTAL SIZE: 10.8(45) SW 280 MONO(45) ENPHASE M250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62939	16041-30000-08094	300 S GRAND AVE #4050	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for title 24 only T.I. in existing high rise. Total area: 6,770 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62940	11041-10000-09631	733 W WASHINGTON BLVD	90291	11	105B149   161	4229010037	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/31/2011 12:00:00 AM	PIN	33.98738806	-118.45403409	TI TO AN EXISTING HOTEL IN MARINA DEL REY (GROUND FLOOR).  T-24 IN LOBBY AREA OTC PLAN CHECK  ONLY.   NO EMERGENCY LIGHTING PER ARCHITECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62941	16041-20000-34025	22627 W ENADIA WAY	91307	12	183B097   251	2024022008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.19908	-118.61963	PV1.  Install 5 kW rated PV system.  (23) modules with (1) 5 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62942	18041-10000-38327	2025 S WESTERN AVE	90018	10	126B193  1184	5073030066	[Q]C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.03801	-118.30921	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62943	17041-20000-18270	21820 W BURBANK BLVD ste 305	91367	3	174B105    44	2146007121	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.17228	-118.6032	ti to an existing commercial building.  non high rise.  adding new lighting new controls to existing panels.  plan check for energy and em lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62944	16041-20001-08312	8931 N RESEDA BLVD	91324	12	195B125   309	2770005013	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	34.23283	-118.53628	05-27-16 Changes to an approved set of plans. Changes include 2x4 Recess change to Recess down lights and additon of outdoor lighting. {{{{{TENANT IMPROVEMENT: OF AN EXISTING RESTAURANT TO A NEW FAST FOOD RESTAURANTplan chk is for title 24}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62945	17041-20001-43975	6038 N JUMILLA AVE	91367	3	177B117   572	2153021013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			Reviewed by Supervisor	12/28/2017 12:00:00 AM	ADDRESS	34.18041	-118.56352	Expedited plan check fee. PV1.  Install 10.03 kW roof mounted grid tied PV system.  (34) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62946	16041-20000-45074	285 S LUCAS AVE	90026	13	133-5A207 285	5153028002	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	05/03/2021 12:00:00 AM	ADDRESS	34.05877	-118.26169	New 5-story, 29 unit hotel building. 800A 120/240V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62947	10041-10000-05366	1848 S WESTWOOD BLVD	90025	5	129B153   645	4321001102	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM			PC Approved	03/24/2010 12:00:00 AM	ADDRESS	34.0489	-118.43585	TI IN AN EXISTING COMMERCIAL AREA.  PLAN CHECK IS FOR TITLE-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62948	14041-10000-26780	6804 N PLATT AVE	91307	12	180B093    21	2028012043	[Q]C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Issued	10/10/2014 12:00:00 AM	ADDRESS	34.19355	-118.64223	T24. REPLACING AN EXISTING EQUIPMENT TO NEW DUE TO FIRE ON UNIT. TOTAL AREA 2970 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62949	14041-10000-30744	12852 W RUNWAY ROAD	90094	11	102B161  1221	4211033040	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	33.97543	-118.41892	Power plan check for a 75KW cogen system back feed to the new panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62950	18041-20000-19659	12304 W MOORPARK ST	91604	2	165B165   402	2367002025	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Apartment			05/25/2018 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	05/24/2023 12:00:00 AM	ADDRESS	34.15015	-118.40107	New  600A 240/120V 1ph-3w service.  Plan check for power and energy. Building permit under 18010-20000-01922.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62951	17041-10001-17514	10250 W SANTA MONICA BLVD # 1867	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	1st revision to approved plan noted under Delta-2, 3, scope: add branch ckts, revise light fixtures schedule, revise load calculation, revise T24 info for First tenant- retail store Sama Ste.# 1867	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62952	17041-20001-02787	9116 W ST IVES DR	90069	4	144B169   247	5560031002	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.09326	-118.39052	expedite per applicant.pv1install roof mounted pv system sized 7.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62953	17041-20001-34466	14333 W JOY DR	91331	6	198B153  1036	2644027248	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.24142	-118.44573	Changes to an approved set of plans. Equipment ratings have changed and PV system size is now 3.8 kWac.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62954	13041-20000-27513	346 E SUNSET AVE	90291	11	109-5A143  41	4286007018	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	33.99564	-118.47388	PV2 COMMERCIAL SPACE. EXISTING MIX USE. TOTAL SYSTEM SIZE 11.4KW AC USING 47 MODULES. 4 STRINGS. 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62955	18041-20000-10595	523 W 6TH ST #710	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,720 sq. ft.Note: Building application has been generated under 18016-10000-05636	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62956	14041-20000-18812	7850 N HILLARY DR	91304	12	189B093   465	2020025006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Expired	08/17/2016 12:00:00 AM	ADDRESS	34.21344	-118.64047	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 7.5KW AC USING CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN. USING DC COMBINER BOX. 3 STRINGS. ROOF MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62957	18041-10000-02793	1122 W 6TH ST #107	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.05419	-118.26301	PC for power and energy for dental office TI. Installing new lights, receptacles and equipment. Total area is 832sqft. B# 18016-10000-02138.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62958	19041-10000-51969	2720 S STANFORD AVE	90011	9	118-5A209 153	5128019014	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	34.01911	-118.2604	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62959	19041-10001-09468	2468 N GLENDALE BLVD	90039	13	148-5A209 168	5440002003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM			Corrections Issued	04/10/2019 12:00:00 AM	ADDRESS	34.102	-118.25907	T-24 PLAN CHECK FOR CHANGE OF USE FROM (E) RETAIL TO NEW WHOLESALE  AND DANCE STUDIO. TOTAL AFFECTED AREA IS 1584 SQ.FT. PARTIAL PERMIT FEES ARE PAID UNDER EXPRESS PERMIT # 19041-90000-09468B#19016-10000-06343T-24 PER INSPECTOR REQUEST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62960	19041-10000-52139	3323 W SAN FERNANDO ROAD	90065	13	153B209   120	5458007012	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM			PC Approved	04/15/2021 12:00:00 AM	ADDRESS	34.11811	-118.24884	PLAN CHECK FOR SERVICE UPGRADE FROM (2-400A) TO 1600A, 120/208V, 3PH, 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62961	17041-20001-15224	801 S BERENDO ST	90005	10	132B197   577	5094014021	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	08/18/2021 12:00:00 AM	ADDRESS	34.05753	-118.29435	7/18/19changes to an approved set of plans.  changes to add fire pump, booster pumps, sewer ejector, jookey pump, and associated wiring.  update backgrounds for unit plans, changes noted delta C only.  ((((Plan check for power and Title 24.  New 7-story low rise mixed-use apartment building with 2 subterranean parking levels. Ground floor retail with 6-story 98 total apartments.  New 3,000 amp 208/120 volt service.  17 typical units.  Project located in methane zone.  Total common area = 84,571 sq. ft.     Building permit #15010-10000-03362))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
62962	14041-20000-09547	18700 W VENTURA BLVD SUITE 110	91356	11, 3	174B121   811	2161026002	(Q)C2-1VL, C2-1VL, R1-1	South Valley, West Los Angeles	Encino - Tarzana, Palms - Mar Vista - Del Rey	Mar Vista, Tarzana		1394.01, 2719.02	Electrical	Electrical	Commercial			04/10/2014 12:00:00 AM			PC Info Complete	05/09/2014 12:00:00 AM	ADDRESS	34.17045	-118.54081	Restaurant in single story commercial building.  A2 occupancy - 266 occupant load.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62963	16041-10000-15547	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	10/13/2018 12:00:00 AM	PIN	34.0586034	-118.41904766	Supplemental to application nos. 13016-10000-16108 and 13010-1000002346 to incorporate all exterior facade, cladding and envelope systmes, exterior finish systems and common area interior finish systems (Package #5).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62964	11041-10000-12934	823-829 W EXPOSITION BOULEVARD N/R Ste 111 &-210	90089	9	117B197   224	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			PC Approved	06/22/2011 12:00:00 AM	PIN	34.01877902	-118.28765493	T.I. for suites number 111 and 210.  Remdeling of the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62965	12041-10000-28085	634-636 S NORMANDIE AVE	90005	10	135B197  1204	5502031001	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			11/21/2012 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	08/01/2013 12:00:00 AM	ADDRESS	34.06239	-118.30017	REGULAR PLAN CHECK. TI FOR EXISTING CHURCH. 3 NEW PANELS, A X-FORMER, 3 AC UNITS, AND NEW CKTS. (TI is for the school attached to the church which is part of the church).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62966	16041-10000-42187	9605 W MONTE MAR DR	90035	5	129B165   570	4306012009	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.04943	-118.39727	PV, INSTALL NEW 5040W DC/4533.48W AC ROOF-MOUNTED SOLAR ARRAY ON ASINGLE FAMILY HOUSE.(18) MODULES: HANWA Q-CELL, Q PLUS-G4 280(1) INVERTER: SOLAREDGE S3E3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62967	10041-10000-21100	11806 W AVON WAY	90066	11	111B161   914	4233022***	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			10/22/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	33.99778	-118.417	Replace the existing fire alarm system with new for existing 4 story condo building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62968	15041-20001-43823	23210 W CASS AVE	91364	3	165B097    31	2076015018	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	34.15217	-118.62113	expedite per applicantPV1 rooftop solar instalation. (38) Q-PRO BFR-G4(38) M215-60-2LL(1) load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62969	13041-10000-27219	2241 W CYPRESS AVE	90065	1	150B213   786	5456013016	RD1.5-1-CDO, [Q]MR1-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.10453	-118.23753	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62970	15041-20001-32752	9542 N LEMONA AVE	91343	7	201B149   757	2650004032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.24391	-118.45864	Expedite per applicant request[[[[[[Plan check for PV roof mounted system. System size: 12.0kW with 49 modules and 49 micr-inverters. 34 modules connected to sub-panel and 15 modules connected to another  sub-panel.]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62971	16041-30001-37885	986 S VERMONT AVE	90006	10	129B197   207	5076001034	C2-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.05277	-118.29141	12/15/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 forms. *****Previous Work Description*****Title 24 plan check.  T.I. to existing El Pollo Loco restaraunt.  Changes to lighting including upgrade to LED fixtures.  Emergency bugeyes and exit signs to remain in place.  Total area = 1,380 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62972	15041-10000-15071	207 S BROADWAY SUITE 700	90012	14	130-5A213  23	5149009022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			PC Info Complete	05/18/2015 12:00:00 AM	ADDRESS	34.05231	-118.24703	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  nEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  SCOPE OF WORK TO BE PERFORMED IN SUITE 700. TOTAL SQUARE FOOTAGE 6620.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62973	15041-20000-21232	434 S GRAND AVE	90013	14	130-5A211  98	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	PIN	34.0506274	-118.25296394	Replacement of defective 2,000 kVA 4,160-277/480V transformer.  Installation of new conductors. refeed existing equipment. no change in loads	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62974	14041-10006-15434	3640 W WILSHIRE BLVD	90010	10	132B193    62	5093019018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			08/27/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.06145	-118.30446	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE ADDITION OF A SUB PANEL TO THE RETAIL SPACE. PANEL CONSIST OF FUTURE LOAD AND 2 WATER HEATERS. NOTE CHANGES ON DELTA 6, CLOUDED AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62975	10041-10001-21843	3050 W PERLITA AVE	90039	13	151-5A211  38	5436032017	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	01/01/2013 12:00:00 AM	ADDRESS	34.11136	-118.24963	Residentail portion , service, panels and branch ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62976	18041-10000-26165	22110 W ROSCOE BLVD	91304	3	192B101   631	2012002019	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Issued	07/13/2018 12:00:00 AM	ADDRESS	34.21937	-118.60854	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62977	19041-20000-50604	5113 N NEWCASTLE AVE	91316	5	171B125   785	2181002022	R1-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Closed	06/24/2021 12:00:00 AM	ADDRESS	34.16237	-118.52524	$0 fee per AB1414PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM AND ESS. PV SYSTEM SIZE IS 10.17/9.7 KW AC CEC. ESS SIZE IS 40.5 KWH. SCOPE OF WORK CONSISTS OF (174) ROOF TILE PV MODULES, (4) PANELS, (3) 13.5 KWH BATTERIES, AND (2) 5.2 KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62978	17041-30000-17155	10410 W BELLAGIO ROAD	90077	5	141B153   203	4362021025	RE20-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	01/07/2022 12:00:00 AM	ADDRESS	34.0814	-118.43695	Plan check for power only in SFD 1,200 A Service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62979	10041-10000-14627	11415 W ROCHESTER AVE BLDG II	90025	11	129B149   103	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Reviewed by Supervisor	01/02/2013 12:00:00 AM	ADDRESS	34.04883	-118.45406	NEW SERVICE, PANELBOARDS, CIRCUITS FOR 15  UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62980	13041-20000-17534	555 S FLOWER ST SUITE 650	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.05048	-118.25755	RENOVATION OF EXISTING OFFICES. TOTAL AREA 3018 SQFT. RELOCATION OF FIXTURES. PC FOR T24 ENERGY ONLY. PART OF HIGH RISE. WORK DONE IN SUITE 650	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62981	17041-20000-39083	17049 W HALSEY ST	91344	12	213B133   423	2607014021	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.28119	-118.50391	PV1.  Install 6.0 kW roof mounted grid tied PV system.  Central/string inverter standard plan.  (24) modules with (1) 6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62982	16041-10000-28553	8930 N LEMONA AVE	91343	6	195B145   175	2651020040	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.23282	-118.45939	PV1. Adding a new solar pv system to an existing pv system. Adding 2.580KWac to an existing 3.0kWac pv system. Total system size with new and existing is 5.583KWac.(12)MODULES-HYUNDAI His-S260RG(12)MICROINVERTERS-ENPHASE M215-602LL-S22(240)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62983	15041-10002-21646	2111 N CAHUENGA BLVD BLDG 1	90068	4	151-5A187 288	5576003043	R3-1	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	34.1091	-118.33132	SUPPLEMENTAL CHANGES TO APPROVED SET INSTALLING EMERGENCY EGRESS LIGHTING STSTEM PER INSPECTOR REQUEST.PERMIT ISSUED UNDER 15041-20000-21646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62984	12041-10001-27053	6060 W CENTER DR 900	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	33.97602	-118.39073	TI  in an existing office. EPC is for T24 & emergency lights. (permit was pulled under app# 12041-90000-27053)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62985	17041-20000-07240	515 S FLOWER ST 48TH FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR BATHROOM, LOBBY AND CORRIDOR. 2080 SQFT.  48TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62986	15041-10002-14886	1200 S BROADWAY	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.03792	-118.26026	CHANGES TO APPROVED SET OF PLANS. UPDATE PER INSTALLED DUE TO NEW SWITCHGEAR LAYOUT. ALL CHANGES NOTED DELTA 20 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62987	10041-10000-06123	7810 W WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2780.00	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	07/09/2010 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	PIN	33.93790872	-118.42837934	"INSTALLATION OF A 3000 AMP, 480/277V, 3P, SERVICE FOR CONTRACTORS TRAILERS AND TAXI-LANE ""S"" PROJECT.  NO LOADS CONNECTED AT THIS TIME."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62988	14041-10002-28433	145 N LA BREA AVE UNIT B	90036	5	138B181   632	5513002010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	ADDRESS	34.07488	-118.34438	Plan check for change to approve set of plan for Title 24 only. ((((PC FOR POWER AND ENERGY. CHANGE OF USE FOR A RESTURANT. TOTAL AREA  2587 SQ FT. FEES PER APPLICANT CALCULATION.(PER SHAUN )))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62989	09041-10001-16833	111 S THE GROVE DR	90036	4	138B177  1129	5512003036	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Public Safety Only			03/09/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	34.0734	-118.35657	Delta 3 modifications to previously approved set of plans. additional devices,j-boxes, relocate the FACP to lobby/entry, remove the annuciator.  New fire sprinkler monitoring system for self storage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62990	12041-20000-14342	19749 W BAHAMA ST	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.2335	-118.56396	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62991	17041-20001-04674	1730 N LA BREA AVE	90046	13	147B181    78	5548002037	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM			PC Approved	01/12/2018 12:00:00 AM	ADDRESS	34.1024	-118.34531	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 23.9 KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62992	14041-10000-23036	12746 W JEFFERSON BLVD Suite 2140	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	plan check for power and energy for wells fargo. (first time tenant).  Total area = 2,544 sq. ft. WELLS-FARGOT.I. to existing shell bldg. BLDG#14016-10-16944. Changes on plan include update MDP demand kva and VD%	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62993	17041-10002-03199	20050 S VERMONT AVE	90502	15	057B197   154	7351033062	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM			PC Approved	05/04/2018 12:00:00 AM	ADDRESS	33.84838	-118.29024	CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE INCLUDES REVISIONS TO LIGHTS DUE TO CHANGE IN ROOM SIZE AND ADDITION OF EXIT LIGHTS. REVISIONS TO T-24 MADE TO REFLECT ALL CHANGES. THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62994	16041-20000-37428	4221 N GOODLAND AVE	91604	2	165B161   785	2375010013	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.14758	-118.41156	pv1install roof mounted pv system sized  7.6kw intercnnected with msp. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
62995	14041-20000-17320	6301 N OWENSMOUTH AVE 10th floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.18467	-118.60176	Commercial office TI on 10th floor of (E) commercial highrise building.  Power and energy plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
62996	12041-10000-02607	22622 W FRIAR ST	91367	3	177B097    56	2039022024	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2012 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.18532	-118.61975	Plan check 7.75KW roof mounted photovoltaic system for single family dwelling. Permit for PV system and upgrading to 125A main service panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62997	17041-20000-40652	5331 E BALTIMORE ST	90042	1	154-5A227 223	5478009042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.11752	-118.20019	PV1.  Install roof-mounted grid-tied 4.875 kW PV system.  (15) modules with 5 kW rated central inverter.Install 27 kWh energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
62998	16041-20000-07062	16830 W VENTURA BLVD 2nd-3rd floor	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.15886	-118.50032	Remodel (E) 2nd and 3rd floor elevator lobbies.  All new lights, all existing circuits.   Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
62999	14041-20000-21099	19801 W LINNET ST	91364	3	171B117   112	2164002019	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.16756	-118.56366	PV1.  Install 9.36 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63000	12041-20000-16244	1080 S LA CIENEGA BLVD 206	90035	5	132B173   684	5087001038	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.05713	-118.37597	T.I. to dental office.  Install general/emergency lighting, change to dental office.  Plan check for power and energy. No critical care areas. Marcel Plaza Unit 206.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63001	18041-20000-44473	3560 S WATT WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.02169	-118.28671	Re-purposing of (E) locker room into biomechanics classroom space. Plan check for Title 24 Part 6 - 2782 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63002	15041-10000-11986	12030 W SHERMAN WAY #3	91605	2	183B165    91	2321003037	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.20028	-118.39552	TI TO AN EXISTING COMMERCIAL BUILDING.  RETROFIT EXISTING LIGHTS TO LED. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63003	16041-20000-35141	9350 N DE SOTO AVE	91311	12	198B109    80	2748002071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	03/17/2017 12:00:00 AM		Issued	03/17/2017 12:00:00 AM	ADDRESS	34.2406	-118.58834	Plan check for energy only. New outdoor lighting under solar carport/canopy. T24 - 11,839sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63004	18041-20000-21737	7722 N KRAFT AVE	91605	6	189B169   899	2316007008	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Issued	06/15/2018 12:00:00 AM	ADDRESS	34.21091	-118.38001	Plan check for PV roof mounted system. System size: 3.0kWac with 10 modules and 1 inverter(3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63005	13041-20001-31807	10809 W HORTENSE ST 3	91602	2	168B177  1130	2421024***	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.15488	-118.3662	(((EXPEDITE FEES)))PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 2.7 KW AC USING MICROINVERTER NONSTANDARD PLAN. ENPHASE M215. PART OF MULTI FAMILY. WORK DONE IN UNIT 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63006	17041-10000-29362	14503 W SHERMAN WAY	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.20136	-118.44932	PC for T24 only for new lighting in retail TI. Installing new lights, receptacles and equipment.  Total area of 1021sqft. Building#17016-10000-20230.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63007	11041-10000-26394	9806 W CRAIGMITCHELL LANE	91040	2	207B181   285	2549024025	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2011 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.26002	-118.3452	Plan check 9.25KW roof mounted photovoltaic system single family dwelling. Modules on house and detached garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63008	11041-10000-17883	14435 W KILLION ST	91401	2	174B149   973	2245007030	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1285.00	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.17095	-118.44757	New fire alarm system to serve (4) bldgs. on site namely Administration, Storage, Classroom East, and Classroom West.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63009	19041-10000-34110	8869 S EARHART AVE	90045	11	096B165   987	4123007009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	33.95652	-118.39301	[EPLAN] PLAN CHECK FOR 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) WITH 13 MODULES USING P320 OPTIMIZERS AND ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63010	17041-10000-09300	6306 S NORMANDIE AVE	90044	8	105B197  1164	6003034023	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	33.982	-118.30008	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 1800 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63011	19041-10000-47424	4124 N CLEAR VALLEY DR	91436	5	165B141   432	2285016017	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	05/30/2020 12:00:00 AM	ADDRESS	34.14591	-118.48475	NOTE: FEES ARE $0 DUE TO AB 1414NEW ROOFTOP SOLAR INSTALLATION. SYSTEM SIZE 21.12KWdc (17.6KWac). INSTALLING 64 CSH1-330MS MODULES, 64 SE P370 OPTIMEZERS & TWO CENTRAL INVERTERS(SE10000H-US & SE7600H-US). CONNECTED TO A NEW 225Amp SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63012	14041-20000-30111	11849 N LOUISE AVE	91344	12	216B133   540	2606015018	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.28569	-118.51092	permit fee charge $0.00 by state senate bill no.1222PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.6KW INTERCONECTED WITH MSP.(48) KYOCERA KD255 MODULES(2) ABB INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63013	15041-10000-14768	3040 S ROBERTSON BLVD	90034	10	123B169   946	4311033017	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.0321	-118.3902	SERVICE UPGRADE,600 AMP, TO AN (E) AUTO BODY SHOP BUILDING. ADDING NEW CIRCUITS CONNECTED TO A SPRAY BUILDING AND PAINT MIX ROOM. PC FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63014	16041-20000-28241	6801 W HOLLYWOOD BLVD Suite 215	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,712 sq. ft. Note: Building application has been generated under 16016-10000-18489	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63015	16041-10000-41701	12121 W WILSHIRE BLVD #1010/1012	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.04386	-118.46816	Plan check for Title 24 only in existing space office T.I. Total area: 1,249 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63016	17041-20000-33217	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.03396	-118.24117	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 98 sq. ft.Note: Building application has been generated under 16016-10000-06970	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63017	15041-20000-43547	6540 N BELLINGHAM AVE	91606	2	180B165   465	2322005030	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.18973	-118.3986	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac(13)MODULES-SUNTECH STP250-20/WD(1)INVERT-ABB PVI-3.0-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63018	14041-10000-25734	6939 N VAN NUYS BLVD	91405	6	183B149   466	2219026066	C2-1L, P-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.19667	-118.44898	FA FOR RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63019	17041-20001-44059	7215 N CLYBOURN AVE	91352	2	183B177    32	2410021009	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM			PC Approved	10/29/2019 12:00:00 AM	ADDRESS	34.20171	-118.36247	SUPPLEMENTAL PLAN CHECK, FOR CHANGE TO APPROVED SET OF PLANS. CHANGE TO SINGLE LINE FROM 200A SERVICE TO 400A SERVICE, SHOWING TOW ADDITIONAL PANELS, (6) NEW BRANCH CIRCUITS, AND (3) NEW 5.1-20 KVA EQUIPMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63020	12041-10000-02033	10100 S AVIATION BLVD	90045	11	090B173   144	4129029013	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/27/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	07/03/2013 12:00:00 AM	ADDRESS	33.94466	-118.37822	New commercial kitchen space, change of use.  New 800A Switchboard and 4 new subpanels, new circuits and loads.  11,450 sq ft of T-24.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63021	11041-10000-07834	600 W 7TH ST	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	CHANGE OF USE FROM RETAIL TO A RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63022	16041-10002-26009	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Issued	05/02/2017 12:00:00 AM	ADDRESS	34.0365	-118.3687	CHANGE TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 5. ADDED WORK. NEW ROOMS AND WIRING TO THEM. UPDATED PANEL SCHEDULES AND T24. PERMIT TO BE ISSUED FOR THE ADDED WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63023	13041-10000-30830	9617 S LA SALLE AVE	90047	8	093A195   244	6055019046	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	33.94805	-118.30587	PV1. ROOFMOUNTED SOLAR ARRAY,INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTER WITH POWER OPTOMIZERS. UNGROUNDED SYSTEM. 1 STORY. SYSTEM SIZE: 3.5 KW.(14) TRINA SOLAR # TSM-250PA05.18(14) POWER OPTOMIZER SOLAREDGE OP250(1) SOLAREDGE # SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63024	15041-20000-26164	18507 W BRASILIA DR	91326	12	213B125   164	2872021002	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.28228	-118.53515	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63025	14041-10000-05697	2472 N LAKE VIEW AVE	90039	13	148-5A209 202	5440024025	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.10193	-118.25417	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(14) MODULES: TRINA SOLAR TSM-250PA05.18(1) SOLAREDGE SE3000A-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63026	17041-10000-07552	10340-10380 N SEPULVEDA BLVD	91345	7	204B145   201	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.2586	-118.46705	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 39 FA DEVICES, AND 1 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63027	13041-10000-01913	1600 N VINE ST	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/24/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.1	-118.32647	UPGRADE LIGHTING IN FITNESS CENTER AND LOUNGE AREA ON 6TH FLOOR IN A HIGH-RISE 13 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63028	16041-20000-18868	10936 W MAGNOLIA AVE	91601	2	171B173  1379	2419001043	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.16469	-118.36943	Paln check Title 24 only in existing space  Yogurtland. Total area: 800 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63029	16041-20000-03634	12410 W SANTA MONICA BLVD	90025	11	126B145   928	4267031004	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	PIN	34.03867846	-118.46667381	INSTALLTION OF A NEW FIRE ALAMR SYSTEM. 1 FACP, AND 49 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63030	19041-20000-28670	2757 S MOTOR AVE	90064	5	126B165   543	4308010018	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.04162	-118.40352	Installation of 27 kWh energy storage system and associated distribution.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63031	15041-20000-24970	217 S AVENUE 20	90031	1	138A221   219	5447024008	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	10/05/2017 12:00:00 AM	ADDRESS	34.07208	-118.21993	Plan check for power and lighting. Project site is a new 2-story commercial building (school) with a basement. Total indoor lighting area = 16,577 sq. ft. Total outdoor lighting area = 9,783 sq. ft.Note: Building plans submitted under application number 15010-10000-02781	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63032	18041-10000-26722	6753 W SELMA AVE 1-11	90028	13	148-5A185 253	5547013014	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			PC Approved	08/06/2018 12:00:00 AM	ADDRESS	34.09981	-118.33766	NEW FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63033	14041-10000-29283	5432 N HERMITAGE AVE	91607	2	174B165   990	2347013014	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			10/22/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.16958	-118.40019	Installation of new fire alarm system with approximately (50) devices. 3-story, 5-unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63034	16041-20000-33770	6000 N CANOGA AVE	91367	3	177B105    70	2149005037	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.17962	-118.59719	Remove existing hid fixtures and replace with new led outdoor lights.  plan check for energy only.  total square footage 34700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63035	16041-10000-16589	530 S MAPLETON DR	90024	5	138B157    50	4359013027	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	07/24/2017 12:00:00 AM	ADDRESS	34.07492	-118.42911	NEW SINGLE FAMILY DWELLING, 1200A SEVICE INCLUDING (2 STORIES 1 BASEMENT). PLAN CHECK FOR POWER ONLY FEES HAVE BEEN PAID UNDER THE BUILDING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63036	19041-10000-40990	2000 S PARNELL AVE	90025	5	129B157   518	4321006041	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.05035	-118.42769	Plan check for a PV1 6kw AC / 6.6KW DC roof mounted system. Scope includes (1) inverter, (22) modules and optimizers interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63037	15041-10000-36378	19821 W NORDHOFF PL #112	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.23686	-118.56502	Remove HID light fixures and replace with new LED fixtures. sq ft = 10976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63038	18041-10000-31315	1200 N AVENUE 54	90042	14	154-5A227  57	5478023031	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.11931	-118.19905	PLAN CHECK FOR 3.8KVA ROOF MOUNTED PV SYSTEM CONSISTING OF CENTRAL INVERTER(SE3800H-US) WITH 12 MODULES USING (P400) OPTIMIZERS APPLICATION TIED IN WITH 18041-10000-31301 SAME PROPERTY	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63039	14041-20001-05631	4600 N WILLIS AVE	91403	4	168A149   149	2265001016	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM			PC Approved	10/14/2014 12:00:00 AM	ADDRESS	34.15426	-118.45511	Fee for Expedite only.*****New roof mounted PV system with 40.26KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63040	14041-10000-22292	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.06188	-118.30486	Installation of fire alarm system in new parking structure.  Total number of devices = 130	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63041	13041-20000-31356	3160 N COLDWATER CANYON AVE	91604	2	159B161   231	2384024011	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2013 12:00:00 AM			Reviewed by Supervisor	12/06/2013 12:00:00 AM	ADDRESS	34.13134	-118.40812	PV1 TRANSFORMERLESS WITH 1200A MAIN. TOTAL SYSTEM SIZE 5.25KW. 21 MODULES AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63042	18041-30000-13045	131 S LA BREA AVE	90036	5	138B181  1006	5513019010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.07261	-118.34429	Plan check for power and energy. Project site is an existing tenant space in a commercial building. Project scope is a first time tenant/tenant improvement. Total lighting area = 957 sq. ft.Note: Building application has been generated under 18016-30000-10978	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63043	18041-20000-41739	9569 S GRANDEE AVE	90002	15	093A213   180	6048019007	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	33.94952	-118.24357	Plan check for PV roof mounted system, system size: 7.2KW DC, 5.0KW AC with 24 PV Modules and 1 inverter(5.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63044	13041-10001-23491	4816 W FOUNTAIN AVE UNITS 1-60	90029	13	147B197  1139	5540015017	[Q]C4-2D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			02/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.09524	-118.29387	(((2/20/15Changes to approved set. Reduction of horsepower in elevator, splitting the kitchen circuits, addition of new circuits, feeder size)))RENOVATION OF A 60 UNIT, 4 FLOORS, RESIDENTIAL BUILDING. REPLACING/ADDING NEW PANELS TO EACH FLOOR. SERVICE SIZE OF 400A. CKTS IN EXISTING PANELS WILL REMAIN EXISTING(JUST PANEL UPGRADE).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63045	16041-20000-05909	542 E ROSE AVE SUITE B	90291	11	111B141   333	4240010008	C4-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	33.99853	-118.47286	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT.  RETAIL. 2800 SQFT. SUITE B	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63046	18041-10000-07052	1620 E 22ND ST	90011	9	118-5A213 303	5118022019	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.01711	-118.2449	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 2750 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63047	14041-10000-21735	3101 W PICO BLVD	90019	10	129B193  1281	5080005020	C4-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Closed	07/27/2018 12:00:00 AM	ADDRESS	34.04735	-118.30952	New manual fire alarm with sprinkler monitoring.  46 total devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63048	14041-20000-16101	812 N HIGHLAND AVE	90038	4	141B185   212	5524004025	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.08567	-118.33841	PC FOR TITLE-24 ENERGY ONLY FOR AN EXISTING COMMERCIAL BUILDING 2,261 SQUAREFOOTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63049	14041-20000-04376	3620 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.0213	-118.28935	T.I. to existing building, portion of the 10th floor.  Install general/emergency lighting.  Plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63050	12041-20000-26788	2844 W ROWENA AVE Lot 2	90039	4	151-5A207 173	5434033010		East Los Angeles			YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	01/23/2013 12:00:00 AM	ADDRESS	34.10762	-118.26616	Enphase system on roof of single family dwelling. Address is also 2848 Buzz Ct.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63051	10041-10000-10846	448 S HILL ST Suite 1201	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.04896	-118.25139	TENANT IMPROVEMENT  IN OFFICES PLAN CHK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63052	13041-10001-36014	12444 N MCLENNAN AVE	91344	12	219B133   460	2609025063	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.29623	-118.50108	Expedited RSES plan check per applicant request.{{PV1, Install 10 kW DC roof-mounted solar array for a two story house, interconnect with service panel.(2)Transformerless inverter: Solaredge SE 6000A-US and Solaredge SE 3000A-US. (40) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63053	19041-10000-11879	11100 W SANTA MONICA BLVD	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.04726	-118.44465	Fire alarm replacement (South Parking Structure and existing 20 Story building) with new FACP and devices. (3) FACP, (698) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63054	17041-20001-25317	13221 N WHISTLER LANE	91344	12	225B133   224	2602003002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.30987	-118.50603	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (42) modules, (42) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63055	17041-10000-10180	5460 W FOUNTAIN AVE 1-75	90029	13	144B193    83	5537002027	R4-2	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Apartment			04/10/2017 12:00:00 AM			PC Info Complete	12/04/2017 12:00:00 AM	ADDRESS	34.09468	-118.30869	Full Plan check for a new 5 story apartment building over subtarrenean parking garage. Total of 75 unit apartments, approximately 7 typical units. New 2000 Amps Main Service 120/208V-3PH-4W. New lighting and power. Area is 64,870 SQft.Building application No. 17010-10000-00027.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63056	10041-10000-03589	1840 S CENTURY PARK EAST 1st. Floor	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	04/07/2010 12:00:00 AM		Permit Finaled	05/05/2010 12:00:00 AM	ADDRESS	34.06188	-118.41473	T.I. for a high rise building (Wells Fargo bank).  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63057	14041-20000-13377	20757 W KINGSBURY ST	91311	12	207B109   389	2706011031	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.26373	-118.58634	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.5KW INTERCONNECTED WITH MAIN PANEL.(30) MODULES RENESOLA 250W WITH POWER OPTIMIZERS(2) TRANSFORMAERLESS INVERTERS SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63058	19041-20000-53245	110 E 9TH ST 6TH FL	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	02/17/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Plan check for Title 24 Energy only in existing space. Installed new track lighting in addtion of existing lighting. Total area: 4766 sq ft.B#19016-10001-13383	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63059	13041-10000-21979	5115 E LONGFELLOW ST	90042	1	150A227   339	5468010007	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1838.20	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Expired	02/03/2016 12:00:00 AM	ADDRESS	34.10362	-118.19755	PV1.  Install 1.47 kW DC roof-mounted solar array, interconnect with main service panel.  {Transformerless inverter: Power-One Aurora PVI-3.0-OUTD-S-US} {6 modules: Trina TSM-245PC05/PA05.18}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63060	17041-10000-40403	741 E 43RD ST	90011	9	114A207   268	5115008016	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.00582	-118.2627	pc FOR NEW ROOFMOUNTED PV ON SINGLE FAMILY. SYSTEM SIZE IS 3.8KWaC/ 3.5KWdcsCOPE INCLUDES 13 MODULES, CENTRAL INVERTER WITH OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63061	16041-20000-27379	11011 N HAYVENHURST AVE	91344	12	210B137   608	2683001024	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.2703	-118.49368	Plan check Title 24 only in existing space break room First Baptist Church. Total area: 165 sq ft.This application refer to Permit #: 16041-20000-14816, X16VN08346	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63062	18041-10000-32303	14645 W KESWICK ST	91405	6	189B149   657	2210025035	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	03/29/2019 12:00:00 AM	ADDRESS	34.21041	-118.45242	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63063	14041-20000-13635	16355 W KINZIE ST	91343	12	201B137   347	2677018016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West	YES	1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Expired	07/28/2016 12:00:00 AM	ADDRESS	34.24858	-118.48907	PV1.  Install 10.455 kW roof-mounted utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63064	15041-10000-43419	777 S FIGUEROA ST # 650	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.04828	-118.26116	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63065	11041-10000-27702	10600 N BAIRD AVE	91326	12	207B125   394	2728022002	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2011 12:00:00 AM	02/02/2012 12:00:00 AM		Permit Expired	02/18/2014 12:00:00 AM	ADDRESS	34.263	-118.5371	New 12.22KW roof mounted photovoltaic system for a single family dwelling. Permit for pv system install and upgrading existing service panel to 225A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63066	13041-20000-26264	16133 W VENTURA BLVD #900	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			Corrections Issued	09/23/2013 12:00:00 AM	ADDRESS	34.15675	-118.4847	Change to lighting and receptacles in an existing high rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for ENergy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63067	19041-20000-21467	7403 S LA TIJERA BLVD	90045	11	099B169   107	4104017043	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	33.97043	-118.37984	first time tenant.  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63068	18041-20000-07770	20644 W CHESTNUT CIR (#333)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.29328	-118.58418	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63069	16041-10000-05129	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.09783	-118.36466	FULL PC FOR AN (E) RETAIL BUILDING, CVS. SCOPE OF WORK INCLUDES NEW LIGHTING AND LOAD OVER 400AMPS. TOTAL SQ. FT. 13342.*** PC TO VERIFY IF SWITCHGEAR IS NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63070	17041-20000-10356	23523 W HATTERAS ST	91367	3	174B093    70	2041004017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.17565	-118.63924	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.3.84kW ungrounded system. (16) EnPhase M250 microinverters. (16) 315W pv modules. Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63071	17041-10002-41641	2301 N HOBART BLVD	90027	4	153B193   211	5588001023	RE11-1	Central	Hollywood	Hollywood United, Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM	ADDRESS	34.1137	-118.30542	**Zero plan check fee per SB-1222/ AB-1414**Supplemental plan check for relocating the solar modules, design & system size remain the same. Permit is covered under master # 17041-10000-41641<<PC for rooftop solar for 10.05kW PV system. Installing 30 new AC modules with 125A load center.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63072	18041-20000-24021	21300 W VENTURA BLVD	91364	3	171B105  1406	2167002006	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.16734	-118.59588	Addition and change of use from restaurant to retail.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63073	11041-10001-02168	5710 S CRENSHAW BLVD	90043	8	108B185   693	5006009008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM			PC Approved	06/30/2011 12:00:00 AM	ADDRESS	33.99053	-118.33046	Modification to aproved set of plans (PCIS# 11041-10000-02168).  Original scope of work was a 600 AMP service upgrade with 4 panels and circuits.  New scope of work is for the 600 AMP service upgrade and the installation of one panel.  The only loads in the panel are air conditioning loads.  All other loads indicated are future loads.  <<<<<Change of use from mechaic shop to retail.  EPC is for Power & Energy.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63074	18041-10000-31336	11111 W SANTA MONICA BLVD 3RD FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	TI IN EXISTING CORRIDOR, ELEVATOR LOBBY & RESTROOMS ON THE 3RD FLOOR.T-24 ENERGY ONLY.  BLDG PERMIT 18016-10000-22285	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63075	15041-10000-03699	3127 N KENNETH DR	90032	14	141A231    86	5213025010	R1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	PIN	34.08196339	-118.18696219	PV1.  Install 3.825 kW roof-moutned, utility-interactive PV system.  Central inverter standard plan.  Applicant could not pull online permit due to addressing issues.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63076	16041-30000-09106	888 S FIGUEROA ST suite 170	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	03/15/2016 12:00:00 AM	ADDRESS	34.0465	-118.26225	Title 24 plan check only.  Total area = 2,662 sq. ft.  T.I. to existing restaraunt space.  3 new subpanels with associated loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63077	11041-20000-12836	14006 W RIVERSIDE DR #60	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Approved	06/28/2011 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I.  Existing retail space.  Remodel of light fixtures.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63078	16041-20001-28234	6801 W HOLLYWOOD BLVD Suite 167	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	10/26/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the lighting floor plan and fixture types. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,368 sq. ft.Note: Building application has been generated under 16016-10000-18486	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63079	10041-20000-21057	18959 W VENTURA BLVD	91356	3	174B121   405	2163020019	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.17265	-118.54653	T.I. to existing space for Massage Salon.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63080	16041-10010-40191	11800 W WILSHIRE BLVD	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.04771	-118.46271	*This is plan check only* Change to approved set by removing and revising some loads and updating the power plan and lighting plan. All changes noted under Delta-21.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63081	19041-10000-21134	400 S LA BREA AVE	90036	4	138B181    62	5525029026	C2-1, C2-1VL	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	11/04/2020 12:00:00 AM		Permit Finaled	04/12/2023 12:00:00 AM	ADDRESS	34.06667	-118.34382	Full plan check for a vehicle sales and repair facility. Scope includes new lighting and equipment. Installing two 800A 480/277 V 3 phase 4 wire services. Total lighting area cover the project is 62,187-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63082	15041-10000-30597	554 S WESTERN AVE	90020	10	135B193   862	5503019001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	ADDRESS	34.06376	-118.3089	Title 24, pc for energy only. Rapairment fire damaged bldg (pet store). New lighting, controls, existing power equipment. Sq ft = 603	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63083	13041-10000-00932	6363 W SELMA AVE	90028	13	148-5A187 313	5546008010	[Q]C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.09989	-118.32893	TI to an EXISTING RECORDING STUDIO. new 800A SWBD. FULL PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63084	14041-20001-03035	8399 N SHOUP AVE	91304	12	192B101   413	2004009001	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.22254	-118.61498	(((expedite fees)))pv1 single family dwelling. total system size 6kw ac using transformerless inverter nonstandard plan. using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63085	18041-20002-17809	8718 N BRADLEY AVE	91352	6	195B173   470	2408026010	[Q]M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	34.22805	-118.37394	Plan check for Title 24 for existing office space T.I. new lightingj. Total area: 600 sq ft.B#16016-20000-27014	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63086	14041-10000-26572	420 E 3RD ST 1000	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.04686	-118.24182	Energy plan check for TI  office inside a  commercial building suite 1000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63087	17041-20001-20920	4201 W WILSHIRE BLVD	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.06189	-118.31911	VOID. NOT EXPEDITE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63088	14041-20000-07934	15831 W SIMONDS ST	91344	12	213B141   414	2666011020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.2765	-118.4773	Roof mounted PV system with tranformerless.  System size 5.2KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63089	13041-20000-18183	16815 W GAULT ST	91406	6	183B133   301	2225018036	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.19945	-118.49942	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW. USING 15 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63090	15041-10001-08938	3501 E VALLEY BLVD	90031	1	136-5A227  63	5211021901	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	ADDRESS	34.06562	-118.20179	Delta 3 revisons-Installing 4ea pole-supported luminaire for the pool deck (((((((((((NEW BATH HOUSE, NEW POOL HOUSE, PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63091	12041-10000-05876	8900 N CORBIN AVE	91324	12	195B117    43	2783025026	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	ADDRESS	34.23252	-118.56211	SHELL STATION. NEW 225A PANEL. ADDING NEW FUEL PUMPS IN CLASS I, DIVISION I HAZARDOUS AREA. PLAN CHECK FOR LIGHTING AND POWER. 768 SQFT CANOPY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63092	15041-10001-42780	12180 W VENTURA BLVD	91604	2	162B165   201	2369004044	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.14307	-118.39788	02/23/2016Changes to an approved set of plans, note changes on delta 3. (((T-24, TI TO A RETAIL SPACE,  ICE CREAM SHOP. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT.868.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63093	10041-20000-19760	16705 W VENTURA BLVD	91436	5	168B137   237	2259011006	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	03/07/2012 12:00:00 AM	ADDRESS	34.15857	-118.49715	New building for car dealership.  New service, panels, branch circuits, and lighting.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63094	19041-10000-16945	1016 S TOWNE AVE #103	90021	14	124-5A211 349	5132009***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.03362	-118.24986	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63095	11041-10001-17761	9247 N VAN NUYS BLVD 1-56	91402	6	198B149   342	2651009003	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Apartment			10/30/2012 12:00:00 AM			PC Approved	10/30/2012 12:00:00 AM	ADDRESS	34.23862	-118.45064	REVISIONS TO APPROVED SET OF PLANS- FEEDERS ON THE HOUSE DISTRIBUTION BOARD ARE CHANGRD FROM AL MC CABLES TO AL BUILDING WIRES; ALARM/STROBE AND HARD WIRED SMOKE ALARMS WITH 9V BATTERY BACK INSTALLED IN THE TWO SEEING AND HAIRING IMPAIRED UNITS.)))))))BRAND NEW 56 UNIT APARTMENT BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  FIRE ALARM WILL BE ON A SEPERATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63096	16041-10000-07076	11265 N ESKO AVE	91342	7	210B181    50	2550020023	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/29/2016 12:00:00 AM			PC Approved	04/22/2016 12:00:00 AM	ADDRESS	34.2746	-118.34765	"PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11KW INTERCONNECTED WITH MSP.(38) SUNPOWER SPR327NE-WHT MODULES(2) POWERONE PVI-6000/5000 INVERTERSThis plan was already approve under 15041-10000-32218, they""ve lost the approved set."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63097	18041-10000-39408	531 N HOOVER ST	90004	13	141A201   210	5539028010	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.08034	-118.28456	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63098	18041-20000-29791	20804 W SPRUCE CIR	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.29496	-118.58705	Plan check for PV roof mounted system, system size: 3.84kW with 12 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63099	11041-10001-02086	2145 W RIDGEVIEW AVE	90041	14	159A223   106	5685025032	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2011 12:00:00 AM			Reviewed by Supervisor	03/08/2011 12:00:00 AM	ADDRESS	34.13072	-118.21398	Photovoltaic system on roof of single family dwelling, rated over 3 KW.  Existing permits for photovoltaic system and new service panels.  See permit application numbers 11041-10000-02086, and 11041-10000-02089.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63100	13041-20000-21032	17080 W SAN JOSE ST	91344	12	207B133   906	2695019004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.26105	-118.5052	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.924 KW. 12 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63101	13041-10000-27273	14618 W SYLVAN ST	91411	6	178-5A151 140	2241011005	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.18442	-118.45151	NEW 4-STORY 10 UNIT APT BLDG, WITH 1ST-FLOOR PARKING GARAGEVARIANCE WILL HAVE TO BE FILED TO SEPARATE THE FA PLANS THAT ARE REQUIRED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63102	19041-10000-02067	4414 E YORK BLVD	90041	1	156A221    16	5474021014	M1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.12377	-118.21995	PLAN CHECK FOR TITLE 24 ONLY FOR - INTERIOR REMODEL AT PHARMACY FOR CVS - TOTAL AFFECTED AREA = 975 SF. - NO RELOCATION OF FIXTURES - ALL NEW FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63103	16041-30000-20270	18981 W VENTURA BLVD	91356	3	174B121   401	2163020020	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Issued	08/30/2016 12:00:00 AM	ADDRESS	34.17265	-118.5472	Note: $0 due to SB 1222PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 34KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63104	14041-10000-04778	942 E LAKE ST A-G	90291	11	111B145  1712	4243003055	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			02/20/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	34.00071	-118.46121	Lincoln place apartment building project. new 2-story apt building with 8 units. addition of three E.V. system and one sub panel and meter is added to existing section.	Y	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63105	14041-10000-02875	1010 S MAPLE AVE UNIT B	90015	14	126A209   275	5145019003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.03785	-118.25427	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 1296 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63106	19041-20000-29520	1745 E 7TH ST	90021	14	124-5A215  58	5164022012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Re-Activate Permit	11/14/2019 12:00:00 AM	ADDRESS	34.0349	-118.23475	addition of new 600 amp distribution board (restaurant distribution) fom an existing service MSA.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63107	11041-10000-14538	5400 S BEETHOVEN ST	90066	11	102B157    43	4211009002	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	33.97779	-118.42187	ADDITION OF NEW FIRE ALARM DEVICES AND REPLACEMENT OF EXISTING FIRE ALARM PANEL TO HANDLE ADDITIONAL DEVICES AT A PRIVATE SCHOOL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63108	13041-10000-29707	11766 W WILSHIRE BLVD STE 1100	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.04804	-118.46227	TITLE-24 PART 6 ENERGY FOR A COMMERCIAL HIGH-RISE BUILDING. EMERGENCY FIXTURES WILL BE FED VIA EXISTING EMERGENCY CKT PER APPLICANT. SCOPE OF WORK IS MAINLY FOR RELOCATING THE FIXTURES ON STE 1100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63109	19041-20000-07146	411 S VIRGIL AVE	90020	13	135B197   628	5077002034	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			02/27/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.06621	-118.28724	PV2.  Install 22.27 kW DC / 20.45 kW AC-CEC roof mounted grid tied PV system.  (61) modules with (2) 10 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63110	17041-10000-04716	23379 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	05/08/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.15883	-118.63416	PC FOR POWER AND ENERGY. bristol farms market: tenant improvement of an existing vacant market building (interior only); EXISTING  SERVICE MOST LIKELY 2500A. ADDITION OF NEW PANELS AND REMOVING THE EXISITING ONES. TOTAL AREA 45804 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63111	08041-10001-12579	5769 W HOLLYWOOD BLVD	90028	13	148-5A191 144	5586032900	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM			PC Approved	09/14/2011 12:00:00 AM	ADDRESS	34.10186	-118.31533	With reference to the service plus motor contribution available short circuit change ( from 93ka  design to 39ka actual, single line was revised to show the new values of short circuit currents at all panel and distribution boards. Also, the main switchboard is two sections instead of the one shown on the approved set of plans. Electrical room drawing was redrawn to show this change.((((((((New 3-story type II-B Fire Station with underground parking. CITY BOND PROJECT. GREEN BUILDING. New 120/208V 3ph, 4W, 800A service. EPC: Power and energy. Variance filed for separate Fire Alarm plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63112	18041-20000-33680	5951 N WOODLAND VIEW DR	91367	3	177B085   460	2032028022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.17886	-118.66419	PV1.  Install 14.3 kW roof mounted grid tied PV system.  (44) modules with 7.6 and 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63113	18041-10000-34883	3400 N CAHUENGA BLVD WEST 1ST FLR.	90068	4	159B181   260	2425001059	C2-1LD	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.1318	-118.35189	TI IN EXISTING OFFICES-NEW LUMINAIRES AND A PANELBOARD, AND NEW CIRCUITSPLAN CHK IS FOR TILE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63114	18041-20000-34659	6200 N CANOGA AVE #210	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.1833	-118.59719	Plan check for Title 24 Energy only in existing office space T.I. on 2nd Floor Total area: 2,866 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63115	15041-20000-00794	3244 S SHELBY DR	90034	5	123B165   695	4311004033	R1-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	04/02/2015 12:00:00 AM	ADDRESS	34.03285	-118.40099	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.(28) SUNPOWER SPR-E20 MODULES(1) FRONIUS 10.0-1-UNI INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63116	17041-20000-32634	907 W 17TH ST	90015	1	126A203   200	5135028007	R3-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.03918	-118.27652	Plan check for solar pv system, roof-mounted on commercial building.22.8kW ungrounded system [(2) 11.4kW].(81) 350W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63117	18041-10000-08655	304 S BROADWAY #440	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR T-24 ONLY.  TOTAL AFFECTED AREA IS 1550 SQ.FT. B# 18016-10000-01045	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63118	19041-20000-41538	20720 W BLUEBIRD CT	91326	12	219B109   502	2701108007	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.29728	-118.58506	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.725 KW AC. SCOPE OF WORK CONSISTS OF (15) PV MODULES WITH INTEGRATED MICROINVERTERS AND A 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63119	16041-20000-41092	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	Corridor lighting in (E) 4-story commercial medical office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63120	18041-20001-30758	11025 N FULLBRIGHT AVE	91311	12	210B113    97	2707026009	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM			PC Approved	09/24/2018 12:00:00 AM	ADDRESS	34.27055	-118.57724	09/24/2018 Changes to an approved set of plans. Inverter location and model has changed. System size has remained the same but inverter is now rated for 10 kWac.*****Previous Work Description*****Plan check for  PV roof mounted system, system size: 15.12 AC CEC with 52 PV modules and 1 inverter(11.4kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63121	15041-10000-16473	1950 W SLAUSON AVE # E-1	90047	8	108B193  1519	6001001022	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	33.98884	-118.31277	ALTERATIONS IN AN AT&t RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63122	19041-20000-02051	1427 S BARRY AVE 1-9	90025	11	129B149   549	4263020020	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.03	Electrical	Electrical	Apartment			04/05/2019 12:00:00 AM	10/15/2020 12:00:00 AM		Permit Finaled	02/18/2022 12:00:00 AM	ADDRESS	34.0459	-118.45673	800A 240/120V 1ph-3w service, distribution, power and lighting for renovation of multifamily residential building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63123	15041-20000-41323	7420 N BELMAR AVE	91335	3	186B117  1024	2116020027	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.20534	-118.55895	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (31)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63124	12041-10000-03372	1700 E CESAR E CHAVEZ AVE L275	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Closed	06/27/2018 12:00:00 AM	ADDRESS	34.05093	-118.21753	T.I. to an outpatient radiography suite on the lower level floor at White Memorial Center.   New Generator, loads, circuits and lighting.  Suite L275	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63125	16041-10000-32751	5100 E YORK BLVD	90042	14	156A225   348	5478006014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM			PC Approved	09/14/2016 12:00:00 AM	ADDRESS	34.12084	-118.20463	PC FOR RESTAURANT TI. NEW LIGHTING. T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63126	18041-10000-02661	700 N ALAMEDA ST	90012	14	132A215   180	5409023930	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM			PC Info Complete	07/26/2018 12:00:00 AM	ADDRESS	34.05488	-118.23748	PC FOR NEW FA SYSTEM AND SMOKE SYSTEM IN (E) HIGH RISE. DEVICE COUNT APPROX. 1100 AND 25 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63127	16041-20001-38323	12934 W VENICE BLVD	90066	11	111B153   935	4236012010	[Q]C2-1	West Los Angeles	Venice	Mar Vista, Venice		2738.00	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	33.99903	-118.44226	Revisions to approved set.  Changes to luminaire schedule and addition of skylights/daylighting control to second story.  (((Plan check for Title 24 only. Project site is a new 2-story art studio. Project scope is lighting. Total lighting area = 11,197 sq. ft.Note: Building application has been generated under 16010-20000-00463)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63128	12041-10005-29911	"12722 W MILLENNIUM BLDG ""B"""	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			05/05/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	33.9761	-118.41564	(((5/5/2015- CHANGES MADE TO APPROVED SET. ADDING ONE SEWAGE EJECTOR)))PLAN CHECK POWER AND ENERGY FOR NEW 4-STORY 103 UNIT APARTMENT COMPLEX. BUILDING 'B'. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED. BUILDING LOCATED IN METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63129	14041-20001-07870	101 S LA BREA AVE	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.07338	-118.34425	Changes from previously approved plans.  Installaton one panel board per tenant.  No 45KVA transformers installation and secondary panels.  Note: Permit is under the original application.*****Previous Description*****IN EACH OF THREE TENANT SPACES, INSTALLATION OF TWO PANELBOARDS, 45KVA TRANSFORMER AND AC UNIT AND CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63130	16041-10000-34948	1999 S AVENUE OF THE STARS 35th flr	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	T.I. TO 35TH FL. 19,200SF full pc for power and energy. load greater than 400A, new lighting new equipment. 2 panels and connecting to existing distribution.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63131	14041-20000-13583	1404 W 223RD ST	90501	15	048B193   684	7347003011	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	33.82439	-118.30179	PV1.  Install 5.13 kW roof-mounted PV system, interconnect with main service panel.  Microinverters.  Nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63132	10041-10000-12152	11521 W SANTA MONICA BLVD	90025	11	126B149    25	4261002018	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			06/25/2010 12:00:00 AM			PC Info Complete	06/25/2010 12:00:00 AM	ADDRESS	34.04543	-118.45271	TI IN AN EXISTING COMMERCIAL AREA. PLAN CHECK IS FOR T-24 ENERGY ONLY. Complete plan check may be required subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63133	11041-10000-26343	11500 W OLYMPIC BLVD #680	90064	11	123B153   223	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.03624	-118.44415	PLAN CHECK POWER  FOR NEW DENTAL OFFICE #680.;  NO CHANGES IN THE LIGHTING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63134	14041-20002-12430	6223 E OAK CREST WAY	90042	14	157-5A231 212	5483017042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.12576	-118.18366	Supplemental Application - Grounding wire increased from #8 to #6 AWG. Change Power Optimizers from SolarEdge P300 to SolarEdge OP250-LV. Change placement of junction box on roof.[[[PV1Installation of roof mounted solar array on SFD. System size: 3kW(1) SolarEdge SE3800A-US transformerless inverter(12) Renesola JC250M-24/BB pv modules]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63135	19041-20000-43747	12846 N WOODLEY AVE	91344	12	222B133   366	2605003019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.30371	-118.5004	Plan check for PV roof mounted system, PV system size: 11.31KW DC, 9.0KW AC with 39 PV Modules an 1 inverter(9.0)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63136	12041-20000-10169	11620 W WILSHIRE BLVD Lower-Level	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM			PC Approved	05/03/2012 12:00:00 AM	ADDRESS	34.05021	-118.45963	T.I. to existing building in corridor and in guard office on the lower level.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-10171	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63137	17041-10000-29736	18033 W SWEET ELM DR	91316	5	162B125    82	2184043031	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.14316	-118.52714	PC FOR PV SYSTEM USING 2 CENTRAL INVERTERS AND 44 MODULES. TOTAL RATING 13KW AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63138	16041-10000-20713	18909 W KINZIE ST	91324	12	201B121   283	2762039005	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.24831	-118.54527	PV SYSTEM WITH 34 MODULES, MICROINVERTER SYSTEM. USING ENPHASE M215. PV SYSTEM WITH ROOF TOP MOUNTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63139	18041-10000-11888	320 W 15TH ST	90015	14	124-5A207  85	5134015025	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.03668	-118.26664	Install a new central utility plant chiller and hot water utilities, new air cooled chiller and water heat pumps and gas boilers and pumps to be installed on the roof. Bldg Permit Number: 18016-10K-09420 New added load > 400 Amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63140	16041-20001-29385	23508 W CANZONET ST	91367	3	171B093   362	2044019011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.16573	-118.63889	EXPEDITE PER APPLICANT REQUESTPV1INSTALL ROOF MOUNTED PPV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63141	14041-10001-03884	5880 W 75TH ST	90045	11	102B169   298	4104013011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	33.9731	-118.38547	"""EXPEDITED PER APPLICANTS REQUEST""PV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. POWER OPTOMIZERS. ONE STORY. SYSTEM SIZE: 6.25 KW DC.(25) CANADIAN SOLAR # CS6P-250PX(25) SOLAREDGE OP300(1) SOLAREDGE SE6000A"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63142	19041-10001-39341	16221 S MENLO AVE	90247	15	069B197   303	6120017035	R2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	33.88379	-118.28939	PLAN CHECK ONLY. CHANGES TO APPROVED SET TO MATCH EXISTING CONDITIONS AND NOT TO  INCLUDES MAIN PANEL UPGRADE. EXISTING 125A PANEL BOARD WITH EXISTING 100A MAIN BREAKER ORIGINAL SCOPE: PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 5KWac/6.270KWdc. SCOPE OF WORK IS 22 MODULES (HANWHA Q-CELL 285 W) WITH OPTIMZERS (SE P320) LEADING TO A CNETRAL INVERTER (SE5000H-US). PANEL UPGRADE PULLED SEPARATELY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63143	14041-20000-22314	15347 W LEADWELL ST	91406	6	186B145   629	2222020025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.20402	-118.46786	Roof mounted PV system with total system size 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63144	16041-20001-21840	6922 W HOLLYWOOD BLVD FLR 6-7	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	03/22/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Scope of work still includes the 6th and 7th floors, but has been reduced. Title 24 has been revised accordingly.*****Previous Work Description*****TI TO AN EXISTING COMMERCIAL BUILDING HIGH RISE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  SCOPE IN 6TH AND 7TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63145	16041-20001-13980	6944 N BEVIS AVE	91405	6	183B149   460	2219016020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2016 12:00:00 AM			PC Approved	05/06/2016 12:00:00 AM	ADDRESS	34.19685	-118.45555	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. PV addition system size is 3.6 kWac and consists of (1) inverter, (18) module, and (1) load center. Total system size is 4.5 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63146	16041-20000-00282	9003 N TERHUNE AVE	91352	7	195B177   217	2544028022	RS-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.23255	-118.36354	Plan check for PV roof mounted system. System size: 12.6kW with 48 modules and 2 inverters(7.6kW and 5.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63147	11041-20000-08525	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM			PC Approved	04/27/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	T.I.  REPLACING AND INSTALLING LIGHTING FIXTURES IN EXISTING OFFICE SPACE.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63148	16041-10002-19293	3013 E ASBURY ST	90065	1	147A217    79	5454031026	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM	ADDRESS	34.09855	-118.23019	Revised modules layout, all other remian the same.<<PV1, INSTALL 4.578 KW DC / 5.00KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: SUNPOWER SPR-327-NE-WHT-D(1) INVERTR: SMA AMERICA SB5000TL-US-22>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63149	12041-20000-03094	19024 W SPRAGUE ST	91356	3	171B121   283	2163024006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2012 12:00:00 AM			Corrections Issued	03/21/2012 12:00:00 AM	ADDRESS	34.16607	-118.54735	Roof mounted PV with 8.4KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63150	16041-10000-07261	1218 S SYCAMORE AVE	90019	10	129B181   179	5084029024	R2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.05277	-118.34616	PV1 SFD TOTAL SYSTEM SIZE 5.76KW AC USING MICROINVERTER SYSTEM. ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63151	11041-10002-04392	1015 W FIGUEROA TER BLDG 1	90012	1	136-5A213  45	5406022078	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			12/06/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.0687	-118.24529	INSTALLATION OF 20HP FIRE PUMPP O BE USED AS A BOOSTER PUMP((((((PLAN CHECK POWER AND ENERGY FOR NEW 22 UNIT APARTMENT BUILDING.  IN METHANE ZONE.  A varinace to separate out the fire alarm appproval was submitted on December 27, 2011.  The methane component of the project was reviewed, and the plan shows substantial compliance with the methane requirements.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63152	13041-20000-02690	4460 W WILSHIRE BLVD 705	90010	10	132B189    45	5090019***	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.00	Electrical	Electrical	Apartment			02/01/2013 12:00:00 AM	02/04/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.06172	-118.32623	"Inspector has requested full plan check. Condo unit. Unit 705. Load less than 400A. Permit for lighting circuits has already been pulled...permit fee for this application is under ""inspection"" fee period."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63153	16041-10000-25379	10400 N SEPULVEDA BLVD UNIT A	91345	7	204B145   113	2649019009	C2-1, P-1, R1-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.25939	-118.46706	PC FOR T24 ENERGY ONLY. NEW LIGHITNG FOR RETAIL TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63154	15041-20000-33108	1200 S GRAND AVE	90015	14	126A207   131	5139023039	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/06/2015 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.03989	-118.26331	Plan check for a fire alarm system. Project site is a new 7-story mixed-use building (apartment and retail). Fire alarm system consists of (1) FACP, (1) annunciator, (10) RPSs, and (1,037) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63155	16041-10000-01461	132 N ALVARADO ST UNIT 1-4	90026	13	136-5A205 289	5157021014	R4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Apartment			01/14/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.06747	-118.26961	remodel of existing duplex and second floor addition with 2 new units.  existing building footprint to remain. 400 MSA, PC for Energy only. Total area (outdoor only) 1901 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63156	12041-20000-20470	9540 N DE SOTO AVE	91311	12	201B109   302	2748023042	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			PC Approved	08/29/2012 12:00:00 AM	ADDRESS	34.24423	-118.58835	T. I. TO (E) MFG; ADD PARTITIONS TO CREATE 1295 SF OF (N) MANUFACTURER ROOMS.  Load is 238.9 Amps, new transformer and panel with circuits and lighting change.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63157	15041-20000-43179	19111 W ARMINTA ST	91335	3	189B121   310	2104006033	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.21392	-118.54963	PV1, rooftop solar installation(68) Q Cells G4-260(68) Enpahse M215-60-2LLNote: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63158	19041-10000-20526	3505 S SEPULVEDA BLVD	90034	5	117B157   244	4252004001	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.01	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.01878	-118.42208	PC FOR  NEW  600A SERVICE ,208/120V,3PH,4WIRE. SCOPE AREA IS 901SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63159	16041-10002-18139	450 S WESTERN AVE #205	90020	10	135B193   649	5503014020	R3-2	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Info Complete	10/06/2016 12:00:00 AM	ADDRESS	34.06562	-118.30887	Full Plan check for first time tenant power only. Title 24 plan check and permit is under application # 16041-10000-18139.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63160	18041-10001-45561	2303-2500 S SIGNAL ST Berth-58, 59, 60	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Issued	08/30/2019 12:00:00 AM	ADDRESS	33.72469	-118.27449	"DELTA ""1"" Changes to approved plans for additional heat sensors.<<<New Fire alarm system for Community Center. Scope includes (1) fire alarm panels, (2) control panels and (74) fire alarm devices.>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63161	11041-20000-00759	11365 W VENTURA BLVD #100	91604	2	162B173   448	2366036025	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.01	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.14027	-118.37796	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR OFFICE TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63162	14041-10001-00976	15858 W OSBORNE ST	91343	12	195B141   168	2672014032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.23367	-118.4783	Expedited RSES plan check per applicant request.{{PV1, Install 5.5 kW DC roof-mounted solar array, interconnect with existing service panel. (1)Transformerless inverter(s): Solaredge SE5000A-US. (22) modules Rensola Solar Modules JC250M-24/BB with (2) Strings of 11 modules.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63163	18041-10000-09597	317 N EUBANK AVE	90744	15	030B209  1063	7424003036	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.77379	-118.25433	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63164	19041-10001-14289	100 E SUNSET AVE	90291	11	109-5A143 198	4286015900	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	33.99395	-118.477	"Changes to an approved set of plans. Changes include relocating the service distribution board on the site plans, reusing exterior lights poles with new LED lamps, revising main breakers and feeders for panels ""LE"", ""LF"", ""LG"", ""LH"", & ""LI"" to 100A."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63165	15041-10000-11855	300 S SANTA FE AVE UNIT S	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.04574	-118.23239	PC FOR POWER AND ENERGY. FOUR STORY BUILDING. FIRSTTIME TENANT RETAIL STORE(MALIN+GOETZ). TOTAL AREA 351 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63166	14041-10000-30176	11834 W VOSE ST	91605	2	183B169   215	2321007008	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.19833	-118.39105	Title 24 plan check only.  Total area = 3,076 sq. ft.Replace HID lighting with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63167	15041-20000-15596	1680 N VINE ST Suit 900	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for Title 24 only T.I. in existing space Suite 900. Emergency egress shall be bugeyes equipment unit per fire variance. Total area: 2,625 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63168	16041-10000-42775	1726 1/2 W KENT ST	90026	13	138A207   113	5404009006	RD2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.07335	-118.26262	PV1 roof mounted solar system installation to a single family home. installing new central inverter rated 3.0 Kw being fed 15.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63169	11041-20000-12590	11845 W OLYMPIC BLVD #850	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM			PC Approved	06/17/2011 12:00:00 AM	PIN	34.03325831	-118.45191172	T.I. to existing high rise building.  Install general/emergency lighting on 8th floor.  Plan check for energy only.Note: Permit issued under 11041-30000-10279	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63170	10041-20000-05160	6081 W CENTER DR #102	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	08/06/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	33.97811	-118.39245	"PLAN CHECK POWER AND ENERGY T. I. FOR SOUPLANTATION RESTAURANT. ""COMPLY WITH DEPARTMENT ORDER effective date07/19/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63171	16041-10000-30957	5757 W WILSHIRE BLVD STE #220	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.06259	-118.35341	PC for energy only. Interior TI to an existing office suite. Adding new lighting and power. Total sqft = 3840.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63172	11041-20000-15846	21550 W OXNARD ST #490	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	ADDRESS	34.179	-118.60001	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING OFFICE #490 TI. HIGH RISE BUILDING. PERMIT #11041-30000-14205	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63173	16041-10000-06855	834 E 88TH ST	90002	9	096A209   156	6042019024	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	03/19/2016 12:00:00 AM	ADDRESS	33.95732	-118.25958	PV 1 roof mounted solar system installation to a single family home. Central inverter is rated at 3.8 kWac, (7) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63174	16041-10000-31075	3052 W SAN FERNANDO ROAD	90065	13	153A213    85	5458001905	[Q]C2-1VL-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM			Reviewed by Supervisor	09/16/2016 12:00:00 AM	ADDRESS	34.11403	-118.24531	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM AUTO PARTS SALES TO MEDICAL OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE AND EXAM ROOMS. TOTAL AFFECTED AREA IS 4835 SQ. FT. B#16016-70000-20633	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63175	19041-30000-08156	1999 S AVENUE OF THE STARS Suite 3400	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only. Project site is an existing tenant suite on the 34th floor. Project scope is a tenant improvement. Total lighting area = 8,050 sq. ft.Note: Building application has been generated under 19016-10000-04388	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63176	16041-10000-24115	19755 W NAPA ST	91306	3	192B117    45	2782018015	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	07/28/2016 12:00:00 AM	ADDRESS	34.22643	-118.56425	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(28)MODULES-LG ELECTRONICS: LG310N1-G4(1)INVERTER-ABB UNO-7.6-TL-OUTD-S-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63177	15041-10000-04573	1317 S ESPERANZA ST	90023	14	118-5A227 245	5191020016	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.01817	-118.20113	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 14060 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63178	17041-10002-34428	2900 W TEMPLE ST	90026	13	138A203    79	5156016027	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM			PC Approved	09/20/2019 12:00:00 AM	ADDRESS	34.07395	-118.2787	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include relocating PV disconnect to the exterior and revising a disconnecting means directory. Note: PC only. Permit under original.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63179	12041-20001-26850	3567 N DE LA CUMBRE PL PV 1	91423	5	159B149   105	2274025021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.13563	-118.44632	Customer changed from single inverter to enphase micro inverters.Permit is on 12041-20000-26850ROOF MOUNTED PV SOLAR SYSTEM 1.78 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63180	16041-20000-23744	5250 N LANKERSHIM BLVD #750	91601	2	171B173   367	2350018086		South Valley				1253.20	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.16668	-118.37545	Plan check Title 24 only in existing high-rise office space T.I. Total area: 3,775 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63181	14041-20000-33101	14500 W ROSCOE BLVD	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Issued	11/26/2014 12:00:00 AM	ADDRESS	34.22136	-118.44937	TI TO AN EXISTING HIGH RISE BUILDING ADDING PARTIAL FIRE ALARM TO THE FIFTH FLOOR.WORK TO BE PERFORMED IN SUITE 500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63182	17041-10000-25651	2029 S CENTURY PARK EAST 1100	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.05956	-118.41375	TITLE 24 PLAN CHECK FOR (INTERIOR OFFICE TI AT SUITE 1100: REMOVE OF DIMISING WALL). TOTAL AFFECTED AREA = 3733 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63183	13041-20000-08647	20905 W VENTURA BLVD	91367	3	171B109    76	2167001015	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	PIN	34.16677631	-118.58862304	"New market and ""Future"" Starbucks at a gas station.  All work is to be outside of classified areas.  New 800 amp MSB, new circuits, lighting, and panels.  Full Plan Check."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63184	14041-20000-01409	215 W 45TH ST	90037	9	112-5A203 120	5110002021	R2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Expired	02/11/2016 12:00:00 AM	ADDRESS	34.00298	-118.27677	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KWA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63185	12041-10000-20602	4636 S LINCOLN BLVD	90292	11	105B153   124	4224014023	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			Corrections Issued	08/30/2012 12:00:00 AM	ADDRESS	33.98239	-118.44062	Ti in a commercial Bldg. Emergency lights are existing.EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63186	16041-10000-35165	1122 W WASHINGTON BLVD	90015	1	126A201   241	5135014042	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.03877	-118.28233	Full PC for power and energy for a New medical office building(Core and shell). Scope includes a new 2500A 277/480 3 phase 4 wire service, new panels, new transformers, and new circuits. Total affected area is 78040 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63187	13041-10001-16216	4297 S CRENSHAW BLVD	90008	8	114B185  1048	5024007023	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM			PC Approved	08/07/2014 12:00:00 AM	ADDRESS	34.00548	-118.33408	CHANGES TO APPROVED (asbuilt): SWITCHBOARD INCREASED TO 100K. Series rated. Plan check only for 1 sheet (E-2.0)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63188	15041-10001-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM			PC Approved	03/08/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Change to an approved set by adding panels and circuits on the original plan. All changes under delta_14 only.permit fee is paid under application number 15041-10001-22097.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63189	18041-20000-39003	12466 N CASCADE CANYON DR	91344	12	219B129   449	2601061011	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.2962	-118.52024	Plan check for a PV1 roof-mounted PV system. System size is 12.35 kWdc/11.86 kWac-CEC and consists of (2) inverters, (38) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63190	10041-10000-14149	3740 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/22/2010 12:00:00 AM			PC Approved	07/22/2010 12:00:00 AM	ADDRESS	34.01972	-118.29033	Ti in an office building in Electrical Eng. building. Plan check only for T24. (Permit # 10041-90000-12768)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63191	13041-20000-31159	10817 W SHERMAN WAY	91352	2	183B173    89	2410019044	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.20136	-118.36644	T24 FOR EXISTING WAREHOUSE. SCOPE OF WORK DOES NOT EXCEED 400A. TOTAL SQRFT 8113	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63192	10041-10000-11362	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	ADDRESS	34.07125	-118.35662	Change of use from Theatre to warehouse. Plan check for Energy and T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63193	15041-10000-39287	5905 W WILSHIRE BLVD	90036	4	135B177   424	5508016901	PF-1D	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Issued	12/16/2015 12:00:00 AM	ADDRESS	34.06282	-118.35793	PLAN CHECK FOR ENERGY ONLY FOR DEMO AND RELOCATE OUTDOOR BOLLARDS AND REDIRECTING EGRESS PATH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63194	13041-20000-00565	17260 W RAYEN ST PV-1	91325	12	195B133   211	2690013012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	04/05/2013 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.23207	-118.5107	PV-1. Coffin Residence. 12.48kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63195	16041-20000-06283	14031 W VICTORY BLVD Apt. 1	91401	2	180B153  1077	2238025005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			02/23/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.18683	-118.43882	Install a roof-mounted solar array on a 3-unit residential building. Interconnect with a 200A MSP.System size: 3kW. Ungrounded system. (7) 265W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63196	16041-10000-38160	14755 W VENTURA BLVD STE B	91403	4	166-5A149  15	2265001006	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.15211	-118.4549	PC for power and energy . Existing optometry office with exam rooms.Change of portion of use to office and retail optometrists.Scope includes  adding new lighting  and new panel (400A 120/208).Totalsqft of 3994 adding	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63197	18041-20000-48847	20061 W SATICOY ST	91306	3	186B113   176	2106006041	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			Reviewed by Supervisor	02/06/2019 12:00:00 AM	ADDRESS	34.20848	-118.57071	Plan check for power only replace 800A switch gear core and shell for future tenant. Some existing load to remain. B#18016-10000-13679	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63198	11041-20000-16333	3415 S SEPULVEDA BLVD #500	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	10/04/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	"PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TI IN SUITE # 500.   ""COMPLY WITH DEPARTMENT ORDER effective date 11/02/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63199	17041-10001-35017	2801 S VINEYARD AVE	90016	10	123B181  1294	5057010013	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM			PC Approved	10/30/2017 12:00:00 AM	ADDRESS	34.0311	-118.34477	Supplemental PC for PV expedite	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63200	19041-10000-11458	3519 W ATWATER AVE	90039	13	153B209   160	5436015020	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	04/11/2019 12:00:00 AM	ADDRESS	34.1183	-118.25881	NEW 6.2KW ROOF MOUNTED PV SYSTEM WITH 21 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63201	10041-10000-00553	6040 W SUNSET BLVD 5th Floor	90028	13	147A189    54	5545013402	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	10/27/2010 12:00:00 AM	ADDRESS	34.0978	-118.32068	Plan check power and energy for 5th floor modification.  Core and shell under #06041-10000-02712	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63202	18041-20000-17072	10555 N NEVADA AVE	91311	12	207B101   167	2723015064	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.26225	-118.60965	pv1install roof mounted pv system sized 12.2kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63203	16041-10000-08312	8931 N RESEDA BLVD	91324	12	195B125   309	2770005013	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.23283	-118.53628	TENANT IMPROVEMENT: OF AN EXISTING RESTAURANT TO A NEW FAST FOOD RESTAURANTplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63204	17041-10001-45235	87 S FREMONT PL	90005	4	132B185   621	5090016008	RE11-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.05658	-118.32867	EXPDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON SFD. TOTAL SYSTEM  SIZE 10.44KWACSYSTEM INCLUDES 36 PANELS WITH MICRO INVERTERS. PLAN CHECKER TO VERIFY SPLIT BUS AND VARIANCE IF APPLICABLE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63205	15041-20000-34863	7900 N NELSON ROAD SUITE A	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.21499	-118.4422	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (LUNCH/OFFICE/WEIGH ROOM). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 1022 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63206	13041-10001-29515	10711 N FULLBRIGHT AVE	91311	12	207B113    82	2707004021	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.26489	-118.57722	Expedited RSES plan check per applicant request. ((((PV1.  Install 12.5 kW DC roof-mounted solar array, interconnect with main service panel.  Multiple inverters.  16 modules: Trina Solar TSM-250PA05.18))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63207	14041-10001-01677	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	02/20/2015 12:00:00 AM	ADDRESS	34.21328	-118.45279	CHANGES TO RECENTLY PERMITTED SET OF PLANS- DELTA 2 CHANGES INCLUDE HAVING LOADS REASSIGN TO OTHER PANELBOARDS(((((((Plan check for power and energy. Total Area for Indoor and outdoor lighting is 56695 sq ft. (31720 interior + 24975 exterior). New electrical systems throughout for fire damaged building. Not methane. GREEN building. Series rated for 65k for available 36KA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63208	15041-20001-25017	14006 W RIVERSIDE DR Space 76	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	09/30/2015 Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,283 sq. ft. Original plans were lost. This is a plan re-check.Note: Building permit has been issued under application 15016-30000-16429*****Previous Work Description*****Plan check for Title 24 only retail T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63209	16041-20001-17875												Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM			PC Approved	06/10/2016 12:00:00 AM				EXPEDITE PER APLLICANT REQUST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63210	16041-20000-07484	19409 W ENADIA WAY	91335	3	183B117   120	2130026021	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.20027	-118.55586	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6.6kW (3+3.6). Ungrounded system. (26) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63211	17041-10000-04826	2558 W SAN FERNANDO ROAD	90065	1	150B213   451	5457002013	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.10789	-118.24149	Plan check for PV roof mounted system. System size: 9kW with 27 modules and 1 inverter(9.0kW 3 phase) connected to 200A Panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63212	15041-10006-43822	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM			PC Approved	03/27/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	DELTA 17 AND 19 REVISIONS TO PERMITTED SET OF PLANS-NEW CIRCUITS FOR POKE-THRU DEVICES AND REMOVING AND ADDING LUMINAIRES ALL CHANGES ARE CLOUDED AND IDENTIFIED AS DELTA 17 OR DELTA 19 WITH NOTES TO DEFINE CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63213	15041-20000-13484	1930 S LONG BEACH AVE EAST	90058	9	118-5A213 351	5167013042	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.01969	-118.2427	$0 permit fee due to senate bill 1222 from 2012Plan check for solar mounted roof for commercial with system size 82.6 kW and 259 modules and 3 inverters(26.8kW) combine to load center(200A)Note: Fire approve is require prior electrical approval	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63214	15041-10000-25028	14006 W RIVERSIDE DR #225	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63215	15041-10001-32503	888 S OLIVE ST 1st Floor	90014	14	127-5A209 127	5144018051	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	02/12/2016Changes to an approved set of plans, note changes on delta 10. Changes include the connection to an emergency panel. (((Plan check for power and eneregy 1st time tenant for fitness center in high rise residential building on 1st floor. Total area: 4,176 sqft.Note: Building application filed under 15016-40000-21187)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63216	13041-20000-34653	5612 N VAN NUYS BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM			PC Approved	12/13/2013 12:00:00 AM	ADDRESS	34.17256	-118.44837	THIS PLAN CHECK ONLY COVERS NEW 200A PANEL AND FEEDER FROM EXISTING METER FOR A FIRST TIME TENANT. PERMIT IS ON APPLICATION#: 13041-20000-31693 **FULL PLAN REVIEW IS REQUIRED FOR THE CONTRACTOR INSTALLING THE LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63217	16041-20000-07067	16633 W VENTURA BLVD	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	Plan check for energy only. TI to existing office in high rise building. New lighting (incl. emergency) and receptacles. 1,655sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63218	19041-10000-25540	18220 W SHERMAN WAY	91335	3	183B125   217	2125036021	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.20092	-118.5303	Plan check for a fire alarm system located in a a 2-story commercial building. Scope includes (1) fire alarm panel, (1) communication panel, and (65) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63219	17041-20001-09071	12700 W VAN NUYS BLVD bldg 5,6	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	12/19/2018 12:00:00 AM		Issued	12/19/2018 12:00:00 AM	ADDRESS	34.27528	-118.4092	12-19-2018 Changes to an approved set of plan, changes include relocate equipment to as built conditons. All changes has been clouded as delta 3. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63220	19041-20000-39557	3107 S THATCHER AVE	90292	11	105B149   162	4229008025	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	33.98741	-118.44932	Install 27 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63221	10041-10000-03583	333 S GRAND AVE 17th Floor	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	03/01/2010 12:00:00 AM		Permit Finaled	04/26/2010 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check T-24 Energy general/emergency lighting for TI on 17th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63222	17041-10000-16761	304 S BROADWAY #350	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.05076	-118.248	PC FOR OFFICE TI IN LOW RISE OFFICE BUILDING FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 1814 SQ.FT.SCOPE INCLUDES NEW CIRCUITS, LIGHTS AND RECEPTACLES.BL#17016-10000-10145	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63223	16041-10000-34598	1320 E 7TH ST	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.03598	-118.24041	PC FOR T24 ENERGY ONLY FOR RETAIL POP UP.S. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63224	13041-10000-25828	19300 W RINALDI ST STE H	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.27414	-118.55457	TITLE-24 ONLY; CONVERTING (E) RETAIL SPACE INTO CHIROPRACTOR OFFICE. TOTAL AREA IS 932 SQUARE FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63225	18041-10000-09092	317 S AVENUE 57	90042	1	150A229   217	5492005010	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.10498	-118.1919	PC for panel upgrade to 600A 5 gang meter service panel for multiple SFD developments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63226	15041-20000-03266	8414 N CREBS AVE	91324	12	192B121   470	2785013022	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.22323	-118.54362	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (20) 327W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63227	14041-20000-20463	222 S FIGUEROA ST 1st Floor	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Apartment			07/29/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.05621	-118.25318	T.I. to existing high rise building partial of first floor (GYM area).  Install general lighting.  Plan check for energy only.  Note: Permit is for replacement of existing units in gym.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63228	13041-10001-26542	8055 W 3RD ST	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.07218	-118.36515	plan check for power and energy. Changes to approved set: outdoor lighting changed and corresponding power and service load calculations updated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63229	13041-10000-01643	1109 N ONEONTA DR	90065	1	154-5A221 350	5475008020	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM			Reviewed by Supervisor	01/30/2013 12:00:00 AM	ADDRESS	34.11635	-118.21617	PV1 ROOF MOUNTED SOLAR INSTALLATION ON TWO STORY FAMILY DWELLING. USING 27 MODULES IN TWO STRINGS, AND ONE TRANSFORMERLESS (UNGROUNDED) INVETERS. SYSTEM SIZE IS 6.615 KW [MODULES: TRINA SOLAR # TSM-245PCO5/PA05.18 |||| SOLAREDGE # SE6000A-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63230	19041-10001-40943	3375 KNOLL	91402	4	159B181   565	5579031013	R1-1	South Valley				1897.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	12/06/2019 12:00:00 AM	PIN	34.1303763	-118.34416829	EXPEDITED FEE PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER WITH 12 MODULES USING P320 OPTIMIZERS AND ESS(LG-RESU10) WITH RELOCATED BACKUP LOADS AND INTERCONNECTION WITH EXISTING 200A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63231	11041-10000-17457	1615 N ECHO PARK AVE 1-13-bldg  2	90026	13	141A209    78	5419008009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Apartment			08/17/2011 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	34.08214	-118.25476	NEW 13-UNIT APARTMENT BUILDING (BLDG 2).  PLAN CHECK FOR ENERGY AND POWER.  VARIANCE WILL BE FILED TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63232	17041-10000-09234	350 S GRAND AVE FLR 8-10	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	PIN	34.05160512	-118.25169569	T-24, PC FOR ENERGY ONLY. RESTROOM UPGRADES ON 665 SQ FT ON EACH FLOOR AT THE 8TH, 9TH AND 10TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 664SQ X 3 = 1992 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63233	17041-10000-15782	900 W WILSHIRE BLVD	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	Title 24 plan check.  New digital display sign on north & south sides of the building facade per DIR 2014-3268-SPP       Building permit #17048-10000-01225	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63234	19041-20000-50301	20143 W VIA GALILEO	91326	12	219B113    67	2701042010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.29607	-118.5723	Plan check for PV roof  mounted system, PV system size: 15.0KW AC, 17KW DC with 43 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63235	11041-10000-22219	8220 N COLDWATER CANYON AVE 101-106	91605	2	192B161   241	2305001035	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.22059	-118.41422	New 800A service for an existing single-story building.  Change of use from auto-shop to shopping center.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63236	14041-10001-34703	5307 W 8TH ST	90036	4	132B181   220	5089001010	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.06064	-118.34513	Inspection permit only. ((((((Plan check for Title 24 only. Scope of work is existing commercial space (salon). Total lighting area = 608 sq. ft.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63237	18041-10000-08509	1700 S SANTA FE AVE B	90021	14	120A217    21	5168001004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.02438	-118.22983	New service for existing building; this plan review is for the service and service equipment ; tenant will be responsible for feeders / panels/ and tenant improvement	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63238	17041-20002-30035	19254 W LANARK ST	91335	3	189B117   160	2104003001	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.21733	-118.55313	"10/10/17changes to an approved set of plans.  changes include down size conduit from 1"" to 3/4""and conductor size from 4 to 6awg on the AC output of the inverter.  this is plan check only.  changes noted delta 1 only.  (((((Plan check for solar pv system, roof-mounted on SFD. Line-side tap interconnection.11.4kW ungrounded system. (48) 275W pv modules.Each module has a 320W power optimizer.$9.21 permit fee due to State Senate Bill SB 1222)))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63239	16041-20000-06194	14647 W LULL ST	91405	6	186B149    88	2210029017	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.20946	-118.45258	Plan check for power only. Project site is an existing commercial building (machine shop). Project scope is a new 600-amp service and electrical distribution equipment. Scope of work does not include loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63240	19041-10000-32990	3621 W 3RD ST	90020	10	135B197   157	5518022011	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2113.20	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Closed	01/11/2023 12:00:00 AM	ADDRESS	34.0692	-118.29492	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63241	17041-20000-32854	11755 W WILSHIRE BLVD #1400	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for energy only. TI to office suite 1400 in high rise building. New lighting (incl. emergency) - 8,221sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63242	17041-20002-14437	11051 W PENDLETON ST	91352	6	198B173    38	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.23953	-118.37198	10.18.2017 - Plan check for modifications to approved set. Update SLD to show actual connected load for conveyor system and panel MCP (400A). Update inverter to 10kW single phase 277V. Relocate equipment - panels 1LA, HA, HL, transformer T-LA, and inverter. Changes clouded delta 6.=======08/04/2017 Changes to an approved set of plans. All changes have been clouded and marked as Deltas 1, 2, and 5. Loads have been recircuited/relocated and there have been slight lighting changes.*****Previous Work Description*****Plan check for Power and energy wearhouse and office space T.I. new panels, lighting and receptacle. Total newly connected load exceed 400A feed from Existing 800A switch gear. Total area indoor lighting: 249,391 sq ft. B#17041-30000-04976	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63243	17041-20000-01645	21015 W OXNARD ST	91367	3	177B105    72	2149005033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.17944	-118.59106	first time tenant for yoga space in a multi tenant commercial building.  plan check for power and energy.  total square footage 1852.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63244	18041-10000-25565	3500 S CRENSHAW BLVD	90016	10	120B185  1013	5044004027	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.02453	-118.33491	PLAN CHECH FOR T24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63245	10041-20000-25259	21700 W OXNARD ST #1870	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			12/20/2010 12:00:00 AM	12/20/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check T24 Energy (general/emergency) for office TI #1870	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63246	16041-20000-45784	17575 W PACIFIC COAST HWY	90272	11	126B117   563	4416012030	C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.04033	-118.56055	Plan check for power and energy. Project site is an existing 3-story commercial building. Project scope is a change of use from restaurant/residential to office. Total lighting area = 14,043 sq. ft.Note: Building application has been generated under 16016-10000-18039	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63247	12041-10002-10813	444 S FLOWER ST	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	ADDRESS	34.05189	-118.25546	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER: 12041-20000-10813. MODIFICATION TO CONTROLS. USING LC&D GR2400 AS AREA CONTROLS AND SHUT-OFF CONTROLS.*******************************************************12041-20000-10813. DESCRIPTION:Tenant improvement for Equinox Gym. Plan check for power and energy. Building is equipped with a generator. Commercial high-rise. 31,700 conditioned sqft. Fire alarm variance will be FILED IN THE FUTURE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63248	15041-20000-09306	10250 W CONSTELLATION BLVD 15TH FLOOR	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Closed	10/06/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. 15TH FLOOR. 19192 SQFT, EMERGENCY LIGHTING. NEWLY CONNECTED LOAD < 400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63249	14041-20000-09909	444 S FLOWER ST 9th Floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.05189	-118.25546	Improvements to 9th floor corridors/restroom in commercial highrise office building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63250	19041-10000-20731	6600 N TOPANGA CANYON BLVD #40	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TITLE 24 ONLY FOR TENANT IMPROVEMENT. INTERIOR TENANT FIT-OUT. NO CHANGE OF USE. REPLACE STOREFRONT - TAILORED METHODPARTIAL PERMIT FEES ARE PAID UNDER EXPRESS PERMIT #19041-10000-34920	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63251	10041-20000-06492	6402 N PLATT AVE	91307	3	180B093   746	2036024053	(Q)C1-1VL, (Q)C4-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	34.18692	-118.64252	Installing light in animal clinic.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63252	15041-10000-13033	1253 N NEW HAMPSHIRE AVE	90029	13	147B197  1182	5540015011	C4-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.09498	-118.29342	PV1, INSTALL 5.46 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME TIE WITH MAIN SERVICE PANEL.(21) MODULES: KYOCERA KU26006XPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63253	18041-10000-13627	9414 W VENICE BLVD 1-6	90232	5	120B165   817	4206028019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM			PC Info Complete	04/13/2018 12:00:00 AM	ADDRESS	34.02508	-118.39513	TI IN AN EXISTING COFFE SHOP. PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63254	16041-20000-21800	2401 N NORTH BROADWAY	90031	9	138A221    61	5204004013	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.07383	-118.21675	Plan check Title 24 only for T.I. T-Mobil retail existing space. Total area: 2,470 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63255	13041-10001-35406	6904 N VANTAGE AVE # 127	91605	2	183B165   722	2321010***	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/29/2014 12:00:00 AM	ADDRESS	34.19578	-118.39751	Expedited RSES plan check per applicant request.{{PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformered inverter: FRONIUS IG 3000 NEG. (10) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63256	16041-20000-43333	5525 N ETIWANDA AVE #324	91356	3	174B125   518	2160011026	(Q)C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.17048	-118.53094	TENANT IMPROVEMENT TO (E) MEDICAL OFFICE.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63257	16041-20000-31312	10535 W VESTONE WAY	90077	5	147B149   614	4370016029	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.1003	-118.44961	Plan check for a power. Project site is an existing single-family dwelling. Project scope is an 800-amp service upgrade.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63258	14041-20000-31227	6725-6727 N FALLBROOK AVE	91307	12	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.19159	-118.62363	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING LIGHTING AND POWER EQUIPMENT.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63259	13041-10002-13915	685 S NEW HAMPSHIRE AVE	90005	10	132B197   143	5094008004	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			09/04/2014 12:00:00 AM			Corrections Issued	09/04/2014 12:00:00 AM	ADDRESS	34.06041	-118.29315	Revisions to permitted set of plans: revised Title 24 compliance forms for the updated indoor and outdoor luminaires; added CU-1 to the rofprovide new load calculations for MS1, MMSB2; NEW LANDSCAPE LIGHTINGPlan check power and for new 7-story 177 unit apartment over 2 level of subterranean parking. Low rise building. 4000A service supplying building. Site located in methane buffer zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63260	13041-20000-34587	13113 W VAUGHN ST	91340	7	216B161   621	2524005029	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.28487	-118.4184	New rooftop PV Enphase system for an existing sfr.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63261	15041-20001-07144	13030 MESA VERDE WAY	91342	7	225B165    19	2580018156	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	03/20/2015 12:00:00 AM	PIN	34.31120672	-118.40409465	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 7.7kW. Ungrounded system. (30) 275W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63262	14041-20001-06251	22605 W GAULT ST	91307	12	183B097   861	2024040009	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.19997	-118.61934	PV1 ROOFTOP MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63263	17041-10000-15383	11338 W SANTA MONICA BLVD	90025	11	129B149   564	4261010908	PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.04591	-118.4498	Title 24 for existing building. Scope includes the replacement of existing fixtures for new fixtures.total affected area = 17,500 Interior Note: outdoor T-24 forms shall be included into fees	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63264	18041-10000-29081	14023 W HUBBARD ST	91342	7	219B153    71	2508009021	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.30046	-118.43849	PLAN CHECK FOR 5.0KVA(AC)/5.02KVA(DC) ROOF MOUNTED PV SYSTEM CONSISTING OF CENTRAL INVERTER(SOLAREDGE SE5000H-US) WITH 17 MODULES USING (P320) POWER OPTIMIZERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63265	18041-20000-21068	651 W 35TH ST LVL-1st Floor	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	PIN	34.02214675	-118.28186522	Plan check for Title 24 only in existing space T.I. new lighting in class room 113J in USC Building LVL 1st Floor. Total area: 459 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63266	17041-10001-44843	8500 N BALBOA BLVD Ste. 130	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	"[This is plan check only, permit is covered under master plan 17041-10000-44843]This is supplemental plan check for ""HemaCare"" Medical building facility (Located in suite 130) for blood extraction and bone marrow collection with labs. Patient treatment is not provided in this facility.Scope includes: installing (2) feeders that connect from (E) MSA dist. board to panel ""HA"" and  a 400A disconnect respectively, which have been plan checked under the master plan 17041-10000-44843."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63267	11041-20000-26710	7368 W MELROSE AVE	90036	5	141B181   610	5526020026	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM			PC Approved	12/14/2011 12:00:00 AM	PIN	34.08331221	-118.35052976	Revisions to P.C. 11041-20000-07745 (AS BUILD ).Reduce Service size from 800A TO 600A .Chang feeders breakers to fuses	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63268	19041-10000-39512	1016 S SANTEE ST	90015	14	126A209   230	5145020034	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM			Reviewed by Supervisor	12/04/2019 12:00:00 AM	ADDRESS	34.03849	-118.25526	FULL PLAN CHECK DUE TO FIRE LOSS. RESTORATION PROJECT. ALL EXISTING DAMAGED INSTALLATION PRIMARILY LOCATED ON THE SECOND FLOOR AND ROOF ARE REPLACED WITH NEW. ALL EXISTING LIGHTING AND POWER IN THE SECOND FLOOR IS TO BE REPLACED WITH NEW.  SERVICE SIZE IS 800A, 120/240, 3PH, 4WIRE.  AREA OF SCOPE (6,619)SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63269	17041-10000-17837	10250 W SANTA MONICA BLVD # 1070	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	02/24/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Existing tenant ""H&M"", adding and replacing luminaires and new circuits. Plan check is for title 24 and 1 ea emergency ckt"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63270	19041-20001-53194	5235 N WOODLAKE AVE	91367	3	171B093   394	2044024001	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM			PC Approved	01/02/2020 12:00:00 AM	ADDRESS	34.16494	-118.63222	EXPEDITEDPV1. INSTALL 18.60 KW DC PV SYSTEM WITH (60) MODULES, OPTIMIZERS AND (2) INVERTERS (SE7600)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63271	17041-20001-10121	400 N MARINE AVE	90744	15	030B205  1269	7418014009	[Q]MR1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	33.77446	-118.26314	05/01/2018 Changes to an approved set of plans. Electrical service distribution equipment has been relocated.*****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. SERVICE UPGRADE TO 1200 AMPS. TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63272	16041-20000-03391	6200 W HOLLYWOOD BLVD	90028	13	148-5A189 130	5546028002	[T][Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			01/29/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.10136	-118.32459	Plan check for Temporary Power for construction of 527 unit apartment building. Service rating 1,600A 277/480V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63273	17041-20000-32238	2652 N PASADENA AVE	90031	1	139-5A221  72	5205021020	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.07805	-118.21503	Plan check for energy only. TI to existing commercial tenant space. New lighting (incl. emergency) - 5,106sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63274	14041-10003-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/29/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	33.95713	-118.3847	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS. SERVICE IS NOW 5000A CENTRALIZED PULL BOX AND CUSTOMER PIPE AND WIRE TO EACH SERVICE PULL UP. THIS IS RECHECKING FOR THE MODIFICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63275	17041-30001-07176	9355 N RESEDA BLVD	91324	12	198B125   167	2763004001	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Approved	05/09/2017 12:00:00 AM	ADDRESS	34.24065	-118.53629	05/09/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3963 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63276	14041-20000-15640	17159 W ENADIA WAY	91406	6	183B133   172	2227021007		South Valley				1320.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.20024	-118.50764	New roof mounted PV system 300W Optimizers and 3.8KW transformerless inverter.  Total system size 4.6KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63277	14041-20001-31050	10036 N LASAINE AVE	91325	12	204B129   444	2734030018	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM			PC Approved	12/02/2014 12:00:00 AM	ADDRESS	34.25319	-118.51217	Fee for expedite only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63278	13041-10001-30049	5260 N BELLINGHAM AVE	91607	2	171B165   327	2347020015	[Q]R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.1663	-118.39912	[changes to approved plans: -removed 15 smoke detectors] original description: FA FOR (E) 4 STORY CONDO BUILDING. R-2 FULLY SPRINKLERED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63279	17041-10000-04711	5301 N FIGUEROA ST	90042	1	150A227    15	5468020015	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.10719	-118.19806	SOLAR ROOF mounted PHOTOVOLTAIC SYSTEM INSTALLATION ON EXISTING BUILDING.Total system size 23.0kwACwith 50 modules and 3 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63280	19041-10000-31375	6706 S MAIN ST	90003	9	102B205   172	6011003062	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.20	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	03/11/2021 12:00:00 AM		Issued	03/11/2021 12:00:00 AM	ADDRESS	33.97852	-118.27375	FULL PLAN CHECK FOR A NEW SERVICE OF 2000 AMPS WHICH INCLUDES A EMERGENCY GENERATOR THAT FEEDS 1000A METER CENTER, AND A 1000A HOUSE DISTRIBUTION BOARD SUBFEEDING 52 SUBPANELS. TOTAL AFFECTED AREA IS 82,837 SQFT. ___________________________________________________________________________*Full plan check FOR A NEW MIXED USE 100%AFFORDABLE HOUSING with a 5-STORY BLDG and 52-units . Scope includes (1) 2000-amp service and a total condition and uncondition area of 82,837-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63281	18041-10000-36234	4551 S GLENCOE AVE 250	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	33.9844	-118.43407	FULL PLAN CHECK FOR INTERIOR OFFICE REMODEL TO CONSIST OF NEW DENTAL EXAM AREAS, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1485	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63282	12041-10000-24567	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/15/2012 12:00:00 AM			PC Approved	10/15/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR T.I. FOR OFFICES ON 8TH FLOOR (SUITE #800) OF HIGH-RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63283	14041-10000-05501	1034 W 50TH ST	90037	9	111B197  1159	5017026059	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Expired	04/27/2016 12:00:00 AM	ADDRESS	33.99764	-118.29285	pc for power only. NEW 800A SERVICE FROM 600A. ALL LOADS (E) PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63284	17041-10000-20794	3677 S BARRY AVE	90066	11	114B157   553	4234017031	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.01009	-118.4275	Installation of new roof mounted solar PV system on existing single family dwelling.  AC module system.  System size = 4.48 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63285	19041-10000-25257	8939 N CANBY AVE	91325	12	195B125   265	2769002016	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Permit Finaled	11/04/2022 12:00:00 AM	ADDRESS	34.23302	-118.53504	pc for pv-1. system size is 13.420kw. 44 modules (Hanwha Qcell) with 320p solar edge optimizers. 11400h solaredge inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63286	19041-20000-10043	2440 N ACHILLES DR pv1	90046	4	153B173   438	5569028003	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.11548	-118.36865	pv1extend an existing pv system to 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63287	18041-20000-22452	23539 W CALIFA ST	91367	3	177B093   850	2041002014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.17747	-118.6398	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters and (35) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63288	18041-10000-18831	6421 1/2 N GLORIA AVE	91406	6	180B141   881	2233014003	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Issued	05/21/2018 12:00:00 AM	ADDRESS	34.18728	-118.47945	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOAL SYSTEM SIZE IS 3.50KWdc / 5.00KWac  (10)MODULES-HYUNDAI HiS-S350TI(10)OPTIMIZERS-SOLAREDGE P370(1)INVERTER-SOLAREDGE SE5000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63289	15041-20002-08838	10710 W CHALON ROAD	90077	5	141B149   147	4362003036	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Expired	09/22/2023 12:00:00 AM	ADDRESS	34.08283	-118.44927	5/7/2019changes to an approved set of plans.  changes to service rating and new panelboards. plan check for power only.   5/10/2019Original permit was issued under Building (14014-30000-04273).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63290	14041-10000-20587	10340 S CENTRAL AVE	90002	15	090B209   705	6065001054	C1-1VL	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	33.94239	-118.2539	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. BANK OF AMERICA. 600 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63291	16041-20000-40362	1314-1342 W ADAMS BLVD	90007	8	123B197   897	5055006012	R4-1L-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.0325	-118.2894	Plan check for power and energy. Project site is an existing commercial building. Project scope is a new service, new distribution equipment, and new lighting. Total lighting area = 26,740 sq. ft.Note: Building application has been created under 16014-10000-05321.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63292	16041-20000-36131	5670 W WILSHIRE BLVD #1000	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.06222	-118.35208	Commercial high-rise office TI.  Plan check for energy.  6925 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63293	15041-10001-11872	9216 S BEACH ST	90002	15	094-5A213 186	6048032042	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2015 12:00:00 AM			PC Approved	05/11/2015 12:00:00 AM	ADDRESS	33.95272	-118.24178	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<,PV1, INSTALL  NEW 5.6 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, TIE WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER SPR32NE-WHT-D(1)INVERTER: ABB PVI-5000-OUTD-USA>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63294	17041-10000-35347	6305 E YORK BLVD	90042	14	153A231    58	5493014015	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Issued	10/03/2017 12:00:00 AM	ADDRESS	34.11487	-118.18221	PC FOR OUTDOOR T-24, REPLACE EXISTING FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 57,600	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63295	19041-20000-51123	20619 W SKOURAS DR	91306	3	180B109   114	2148003008	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.19272	-118.58255	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 4.38 KW DC/3.48 KW AC. SCOPE OF WORK CONSISTS OF (12) PVMODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63296	12041-10000-05702	9361 N GLENOAKS BLVD	91352	6	198B173    44	2538010006	M2-1-G, M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			Reviewed by Supervisor	05/10/2012 12:00:00 AM	ADDRESS	34.23894	-118.37636	NEW 1800A SERVICE. NEW PANELS AND CIRCUITS. OUTDOOR. PREWASH STATION FOR A PLASTIC RECYCLING PLANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63297	16041-20000-12908	640 N FRIES AVE	90744	15	030B205   667	7416034041	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.77814	-118.2647	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,887 sq. ft.Note: Building application has been created under 16016-20000-05066	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63298	13041-20000-33779	15032 W TUBA ST	91345	7	204B145   459	2660019005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.25621	-118.45996	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 4.32KWAC. 20 MODULES AND MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63299	13041-10001-32957	13280 N DRONFIELD AVE STE# 21	91342	7	225B153   556	2504018***	RD3-1-K	North Valley	Sylmar	Sylmar		1064.08	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.31289	-118.44322	Expedited RSES plan check per applicant request.[][]PV1, Install  4 kw DC roof-mounted solar array for a 2 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 16 modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63300	15041-20000-38223	18418 W DEARBORN ST	91325	12	198B125   247	2764013002	(Q)R3-1	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Apartment			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.23708	-118.53429	Plan check for replace fire alarm panel and 1 smoke dector with existing fire alarm devices to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63301	15041-20000-10511	7204 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	34.24845	-118.28886	CONVERT (E) RETAIL SPACE INTO MEDICAL OFFICE. pc for powre and energy. health care art 517	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63302	17041-10000-37573	445 S FIGUEROA ST 9TH FLR	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Info Complete	10/19/2017 12:00:00 AM	ADDRESS	34.05295	-118.25675	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE/PANTRY SPACE ON THE 9TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 370 SQ. FT. B#17016-10000-30740	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63303	16041-20000-41023	567 S FAIRFAX AVE	90036	5	135B177   371	5510019036	C2-1VL-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.06552	-118.36154	"Plan check for energy only. Change of use from health club to retail & dog day care. New lighting in ""small dog waiting area"". New emergency lighting and exit signs in lobby and retail areas. 543sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63304	11041-10000-12799	3435 W TEMPLE ST	90026	13	139-5A201 141	5156001002	CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village		1958.02	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM			PC Approved	07/18/2011 12:00:00 AM	ADDRESS	34.07672	-118.28404	TI TO AN EXISTING 2-STORY OFFICE BUILDING.  PER CUSTOMER AREA IS NOT IN A HAZARDOUS CLASSIFIED OR METHANE ZONE AREA AND ALL PANELS ARE EXISTING.  PLAN CHECK IS FOR T-24 (ENERGY) ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63305	16041-10001-02086	1245 W WILSHIRE BLVD SUITE 680	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	CHANGES TO APPROVED SERT OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO LOW VOLTAGE CONTROLS INSTEAD OF LINE VOLTAGE. UTILIZING ROOM CONTROLLERS AND LOW VOLTAGE CONNECTION TO ROOM CONTROLLER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63306	10041-10000-10355	121 E 6TH ST	90013	14	127-5A211  48	5148020007	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM			Corrections Issued	07/13/2010 12:00:00 AM	PIN	34.0448716	-118.24914723	INSTALLATION WIRING OF AN EXISTING FIRE PUMP AND ASSOCIATED EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63307	19041-20000-11826	1855 N ECHO PARK AVE	90026	13	142-5A211 108	5420023004	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	Yes	1974.20	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.0855	-118.2529	Plan check for Energy storage system into existing PV system. Tesla PowerWall 2.0 13.5kWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63308	17041-10001-23640	3195 N GLENDALE BLVD	90039	13	154-5A207 219	5435026022	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.11796	-118.26127	PC FOR T24 ENERGY ONLY. UPDATED PLAN SET. THIS SET TO SUPERCEED PREVIOUS SUBMITTAL. UPDATED ENGINEER ON RECORD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63309	17041-10000-05062	2623 E MEDFORD ST	90033	14	135A229   131	5202022020	M2-1	East Los Angeles	Northeast Los Angeles	LA-32		2031.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Issued	02/16/2017 12:00:00 AM	ADDRESS	34.06257	-118.19411	T-24, PC FOR ENERGY ONLY. REPLACE HID FIXTURES WITH NEW LEDs FOR INDOOR USE. TOTAL AFFECTED AREA IS 7000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63310	17041-20000-34648	925 W WEST 34TH ST 4th Floor-Restrooms	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.0239	-118.28647	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 550 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63311	17041-20000-05902	865 S FIGUEROA ST Suite 3345	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for energy only. TI to office suite 3345 in high rise building. New lighting (incl. emergency). 2,067sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63312	09041-10001-13995	267 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM			PC Approved	07/07/2010 12:00:00 AM	PIN	33.94684048	-118.40128468	TEMPORARY REROUTING OF 480V CONDUITS FROM PANEL DPD-1 AND MV CONDUITS FROM 5KV SWITCHGEARS TO  MH # B4 (4160V) AND TO MH # E4A ( 480V). ORIGINALLY APPROVED FOR UNDERGROUND ROUTING, THESE CONDUITS NEED TO BE REOUTED ALONG THE SIDE OF THE PARKING STRUCTURE 2A DOWN TO UNDERNEATH EXISTING BRIDGE  TO THE MANHOLES .CONDUITS  SHALL BE IN CONFORMANCE WITH TABLES 225.60;225.61 340.30B (2)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63313	15041-10000-19734	2335 N DORRIS PL	90031	13	144B213   205	5445005***	[Q]PF-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM			PC Approved	06/23/2015 12:00:00 AM	ADDRESS	34.09237	-118.23609	Energy plan check for a maintenance yard canopy and flood light replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63314	11041-20000-06688	20721 W SUPERIOR ST	91311	12	201B109   203	2748004049	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.24646	-118.5849	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR COMMERCIAL SPACE. PERMIT TO REPLACE ONE EXISTING PANEL AND INSTALL NEW BRANCH CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63315	15041-20000-17152	555 W 5TH ST 4580	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM			PC Approved	06/04/2015 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check for SUNPAC LLC office T.I. in high rise  Title 24 only. Total area: 9510 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63316	19041-20000-03789	11544 W VENTURA BLVD	91604	2	162B169   610	2369036003	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.13966	-118.38331	PC FOR FA. 1 FACP AND 9 DEVICES FOR CHANGE OF USE FROM FURNITURE STORE TO CHILD CARE FACILITY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63317	19041-10000-34350	11302 W VICTORY BLVD	91606	2	180B173   909	2336016005	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Issued	08/30/2019 12:00:00 AM	ADDRESS	34.18651	-118.37711	NEW SPRINKLERS MONITERING STATION FA SYSTEM. SCOPE INCLUDES NEW FA PANEL, COMMUNICATOR AND 7 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63318	17041-20000-34095	10324 N MT GLEASON AVE	91042	7	204B193   562	2558006002	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Apartment			09/22/2017 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	08/25/2020 12:00:00 AM	ADDRESS	34.25663	-118.30252	600A service, distribution, power, and lighting for new construction.  Plan check for power and enerygNote: Building application has been generated under 17010-20000-03658	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63319	15041-10000-04745	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.07196	-118.24719	Power plan check for installation of above ground fuel tank with two pumps and one subpanel to supply power.  Project is considered a class 1 hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63320	16041-10007-04795	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	ADDRESS	34.0631	-118.36086	VOID per applicant request. change to an approved set. change under delta 44 only. changing the suppling switchboard of 2 elevators 1-50HP & 40HP.  B# 13014-10000-03762	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63321	13041-10000-36246	18720 W SAN FERNANDO MISSION BLVD	91326	12	210B121   169	2717007026	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.27361	-118.54153	PV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL INVERTER. NON STD PLAN. SYSTEM SIZE 13.08 KW DC.(40) SUNPOWER SPR-327 W MODULES(1) SUNPOWER SPR11401 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63322	12041-10000-10151	3630 W WATT WAY	90089	8	118-5A201  14	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.02062	-118.28738	New 4-story commercial  building at USC.  Service size is over 1200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63323	14041-20001-06001	5333 N ROYER AVE	91367	3	171B097   200	2042010042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM			PC Approved	03/16/2014 12:00:00 AM	ADDRESS	34.16762	-118.62785	((expedite fees))pv1 single family dwellding. ttoal system size 6kw ac using transformerless inverter nonstandard plan. using power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63324	17041-10000-03359	134 S DENSLOW AVE	90049	5	138B149   148	4366023005	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.07366	-118.45826	PC FOR  A ROOF-MOUNTED PHOTVOLTAIC SYSTEM USING 7.6KW INVERTER WITH BATTERY BACK UP SYSTEM, USING TESLA POWER WALL. INSTALLING BACK UP LOAD CENTER AS WELL. TOTAL OF 16 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63325	10041-10001-22337	20022 W VENTURA BLVD	91364	3	174B113   466	2166001020	C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM			PC Approved	08/08/2011 12:00:00 AM	ADDRESS	34.17141	-118.56915	Modification to an approved set of plans.  Original Title 24 was plan checked under 10041-20000-22337.  Plan check is for energy only.  <<<<<<PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR RESTUARANT TI. PERMIT FOR NEW (2) PANELS AND NEW CKTS. MISC PERMIT TO RE-FEED EXISTING BRANCH CKTS TO NEW PANEL.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63326	17041-10000-07814	1120 W 6TH ST	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.05418	-118.26297	FIRST TIME TENANT FOR A NEW COFFEE SHOP(STARBUCKS). SCOPE INCLUDES NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 1915 SQ. FT. B#17016-10000-0148	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63327	15041-10000-19406	3326 S MAIN ST	90011	9	118-5A205 200	5120003010	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	PIN	34.01864854	-118.27218528	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 15.4KW INTERCONNECTED WITH MSP.  (55) CANADIAN SOLAR(2)SMA AMERICA SB 7700 TRANSFORMERLESS INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63328	16041-20000-22214	11328 W MAGNOLIA BLVD	91601	2	171B173   632	2353002041	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.16476	-118.37838	PV2. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 12. 4 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63329	14041-20000-00653	7058 N COLBATH AVE	91405	2	183B153   360	2216007006	R1-1	South Valley		Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.19933	-118.43658	New 6.24kw rooftop PV system for an existing single family dwelling.  System is UNGROUNDED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63330	14041-10000-05710	1339 N AVENIDA DE CORTEZ	90272	11	138B117   338	4431005029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.07166	-118.56009	Existing SMA6000 negatively grounded inverter to share same solar load center as new installation.PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(14) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63331	12041-10000-25326	2112 W 7TH ST	90057	1	132A203   100	5141018002	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.05652	-118.2774	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR CHANGE OF USE FROM RETAIL  TO SUBWAY RESTAURANT. LESS THAN 100 OCCUPANCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63332	11041-10000-01682	11976 W CULVER BLVD 1-124	90230	11	108B161   154	4218007025	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Apartment			01/27/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	33.99512	-118.4173	New 124-units affordable housing 4-storie over parking garage on grade. EPC is for power & Energy. (T24 fee is not included)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63333	18041-20000-24993	555 N CRESTLINE DR	90049	11	135B141   125	4402030006	RA-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.0691	-118.47783	New 2-story addition to (E) 2-story SFD.  600A 240/120V 1ph-3w service.  Note: Building permit under 17014-30000-06557. Electrical permit fees have been paid under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63334	14041-10000-05209	12421 W RYE ST	91604	2	165B165   179	2364016017	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	06/19/2014 12:00:00 AM	ADDRESS	34.1514	-118.4039	PV1.  Install 6 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE5000A-US-ZB-U.  24 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63335	12041-20001-18811	731 N ST ANDREWS PL	90038	13	141B193   444	5535015003	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			11/15/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.08445	-118.31149	Modification to previously approved set of plans to change all 47 unit panels from 60 to 30 amps based on calculated per unit load from approved set of drawings.    <<<<new service and feeders to all apartments>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63336	13041-10000-27690	20900 W VENTURA BLVD	91364	3	171B109    98	2167024029	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.1662	-118.58863	Plan check power and energy for new Chase bank.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63337	13041-10000-05340	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM			PC Approved	03/08/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	T24 FOR DEMO'ED OFFICE SPACE. 6240 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63338	13041-10000-07977	222-234 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	11/24/2014 12:00:00 AM		Issued	11/24/2014 12:00:00 AM	ADDRESS	34.05621	-118.25318	Remove gas generators and install two diesel generators rated 650 KW.  Reconnect powers to two existing fire pumps.  Install two new dedicated services (1000A each) for fire pumps.  Plan check for power only.  Location in Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63339	13041-20000-25018	15963 W STRATHERN ST	91406	6	189B141    23	2206005021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/11/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.21581	-118.48145	REPLACE DAMAGED 2000A FEEDER. ADDED 2000A MAIN DISCONNECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63340	15041-10000-26607	16423 W VICTORY BLVD	91406	6	180B137   741	2231005028	[Q]R3-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Apartment			08/14/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.18681	-118.49104	PC FOR ENERGY ONLY, T-24, TO A NEW 400 AMP SERVICE APARTMENT BUILDING. SCOPE INCLUDES GARAGE AND OUTDOOR LIGHTING. TOTAL SQ. FT. 8941	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63341	19041-10000-30236	515 N BEACON ST	90731	15	018B201   184	7449007900	C2-2D-CPIO	Harbor	San Pedro	Central San Pedro	YES	2962.10	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Closed	06/05/2020 12:00:00 AM	ADDRESS	33.74742	-118.28054	PLAN CHECK FOR POWER AND ENERGY FOR HOMELESS SHELTER - TOTAL NEW CONNECTED LOAD >400A WITH SERVICE SIZE OF 400A AT 480/277V. (TITLE 24 NOT REQUIRED)SERVICE IS FEEDING MODULAR BUILDING (SHOP FAB. BUILDING WITH DEMAND LOAD HAVE BEEN INCLUDED)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63342	13041-10000-26661	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	33.96577	-118.42406	"ADDING 225KVA STEP-DOWN XFORMER AND 600A DISTRIBUTION PANEL FOR LOYOLA MARYMOUNT UNIVERSITY. FEEDER LENGTH FROM EXISTING DISTRIBUTION SWBD. ""MSA"" TO PROPOSED XFRMER IS AROUND 335FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63343	10041-20000-24148	5633 N TOPANGA CANYON BLVD	91367	3	174B101   197	2146008022	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Apartment			12/03/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Issued	12/03/2010 12:00:00 AM	ADDRESS	34.17304	-118.60612	New fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63344	17041-10000-16718	9689 W MOORGATE ROAD	90210	5	156B157   191	4385017014	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Expired	09/05/2023 12:00:00 AM	ADDRESS	34.12483	-118.42767	Installation of new roof mounted solar PV array on existing single family dwelling.  Two central inverters connected to new 125 amp load center.  Total system size = 11.4 kWac.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63345	17041-10000-06298	20630 W PLUMMER ST	91311	12	198B109    51	2748041022	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.24249	-118.58309	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  6800 SQ FT. ( INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63346	10041-20000-06415	4520 W ELECTRONICS PL	90039	4	162B205    11	5593012025	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Public Safety Only			04/08/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.14462	-118.27312	Fire Alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63347	13041-10000-02055	2700 W COLORADO BLVD SUITE 239	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			PC Approved	01/28/2013 12:00:00 AM	ADDRESS	34.14248	-118.22438	TI FOR OPTOMETRY SHOP UNIT IN EAGLE ROCK PLAZA.  T24 LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63348	15041-10000-26173	7661 W MELROSE AVE	90046	5	141B177   558	5527007003	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.08385	-118.35673	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2460.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63349	17041-20002-18116	16916 W PARTHENIA ST	91343	12	195B133   471	2689018022	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.22834	-118.50096	06/09/2017 Changes to an approved set of plans. Changes have been marked as Delta 1. Non-applicable notes have been removed from the plan set.6.5.2017 - Plan check for installation of exit signs. (4) new exit signs and (5) new receptacles for massage parlor.=====New circuit for water heater / outlet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63350	11041-10000-00761	975 N VENDOME ST 1-36	90026	13	142-5A203 305	5426016003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.01	Electrical	Electrical	Public Safety Only			01/13/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.08417	-118.27465	INSTALLATION OF FIRE ALARM SYSTEM.  ELECTRICAL PLAN CHECK FOR POWER.  COMPLY WITH  DEPARTMENT ORDER effective date 04/16/2007. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63351	12041-20000-30030	21431 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	06/13/2013 12:00:00 AM		Issued	06/13/2013 12:00:00 AM	ADDRESS	34.25739	-118.59841	Plan check for power and energy. Ti to Ralphs #710. 20615 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63352	15041-20000-28725	4334 N MATILIJA AVE 1-27	91423	4	165B153   431	2271017029	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.14952	-118.43388	PV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 15.4KW AC USING 2 CENTRAL INVERTERS AND 66 MODULES IN TOTAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63353	10041-10001-25752	5533 W HOLLYWOOD BLVD	90028	13	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM			PC Approved	12/05/2012 12:00:00 AM	ADDRESS	34.10188	-118.31038	REVISED LIGHTING PLANS TO SHOW IMPROVEMENT IN AREAS OF THE BUILDING THAT WERE SHOWN TO BE OPENED.TITLE 24 FORMS WERE REVIED TO ACCOUNT FOR THE IMPROVEMENT.Remodel existing residential building into a mixed use retai residential building.  Plan check is for electrical, and for common lighting and dwellling unit T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63354	19041-20000-03247	11409 W PENROSE ST	91352	6	192B169   394	2632011012	M1-1-G-CUGU, M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.22308	-118.37994	plan check for hazardous location class 1 div 2.  installation of new gas tank.this is plan check only. permit fees paid under application 180-70000-46356	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63355	17041-10000-10581	20141 W MAYALL ST	91311	12	204B113   460	2741011058	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.25374	-118.57259	Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system with two branches.  Total system size = 6.9 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63356	10041-20000-21074	1207 S VERMONT AVE	90006	1	129B197   797	5078028004	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			10/22/2010 12:00:00 AM			PC Info Complete	01/11/2011 12:00:00 AM	ADDRESS	34.04886	-118.29184	New fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63357	16041-10001-09201	6600 N TOPANGA CANYON BLVD #1017	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM			PC Approved	04/01/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	"Supplemental [PC Only] to an approved plan under Delta-1: Adding ""Manufacturers"", ""Models"", and ""Comments"" on table lighting fixture schedule 1.***TI TO AN EXISTING COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO EXISITNG PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2603."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63358	14041-10001-16672	5778 W OLYMPIC BLVD	90019	4	132B177   764	5085004036	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			07/12/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM				Changes to approved set.  Reduce service size to 800 amps and remove AC units.  Service change to overhead.  Revised voltage drop and fault current calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63359	17041-30001-39785	1440 N ALTA VISTA BLVD	90046	4	147B181  1185	5548018040	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.09712	-118.34686	12/13/2018 Changes to an approved set of plans. Lighting controls have been revised to match field conditions.*****Original Work Description*****Plan check for Title 24 only in existing corridor for 1st, 2nd and 3th Floor. Total area: 3250 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63360	13041-20000-13850	20658 W LUGANO WAY	91326	12	213B109   277	2701064037	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	34.27903	-118.58353	New rooftop PV System for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63361	13041-10000-01893	590 N VERMONT AVE	90004	13	141B197   776	5539033010		Central				1927.00	Electrical	Electrical	Commercial			01/30/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.08157	-118.2915	Install new outdoor light, 108687 square feet..  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63362	16041-10004-30867	5132 N EL RIO AVE	90041	14	163-5A221 309	5671016019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	34.1405	-118.21606	Changes to approved set.  Addition of new AC disconnect.  Remove trench.       (((((PC for new rooftop PV solar system with 41 modules, 1 SB7700TL inverter rated at 7680W,1 SB5000TL inveter rated at 5000W and 1 load center. Installing modules in front of housewith main panel located in backhouse.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63363	15041-10000-08258	7910 N CLYBOURN AVE STE A	91352	2	189B177   393	2466031026	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.21443	-118.36393	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACE EXISTING FIXTURES WITH LED LIGHTING.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63364	17041-20001-24213	153 S BURLINGAME AVE	90049	11	132B137   582	4406012002	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	ADDRESS	34.05509	-118.49116	expeditepv1install roof mounted opv system sized 15.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63365	17041-30000-12617	601 S FIGUEROA ST Suite 2000	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM			PC Approved	04/18/2017 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 460 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63366	14041-20000-24073	23723 W SANDALWOOD ST	91307	12	186B093   315	2027017018	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.20561	-118.64344	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 8.8kW.(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(36) Trina solar TSM-255PA05.18 pv modules(36) SolarEdge P300 power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63367	18041-20001-06102	13245 W RIVERSIDE DR #400	91423	4	168B157   316	2358014027	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM			PC Approved	08/06/2018 12:00:00 AM	ADDRESS	34.15778	-118.42187	Revisions to approved set of plans.  Lighting design changes - recessed ceiling omitted from certain rooms/areas. (((TI to (E) commercial office space.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63368	18041-10000-33169	10223 W WOODBINE ST	90034	5	120B161   104	4314023024	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	12/30/2020 12:00:00 AM	ADDRESS	34.02858	-118.40809	NEW 4-STORY, 9-UNIT MULTI-FAMILY DWELLING OVER 1-LEVEL SUBTERRANEAN GARAGE.BLDG PERMIT: 16030-10000-09198	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63369	12041-20000-14334	1100 S BERENDO ST	90006	1	129B197   485	5078026028	R4-1VL	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			06/20/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	12/05/2012 12:00:00 AM	ADDRESS	34.05071	-118.29357	Roof mounted P.V. system (5.98KWdc).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63370	11041-20000-08974	2900 S SEPULVEDA BLVD	90064	5	120B157    63	4251003009	(T)(Q)RAS4-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Apartment			05/03/2011 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.02876	-118.42927	New apartment with 1600 Amp service.  File for variance to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63371	19041-20000-24485	14344 W SHERMAN WAY	91405	6	183B149    71	2217006008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	07/23/2020 12:00:00 AM	ADDRESS	34.20103	-118.44591	"Plan check for  place of assembly ""A"" Occupancy Repair/Remodel Fire Damage existing church, existing 600A Service. Total area: 8207 sq ft. B#18016-20000-40846"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63372	13041-10000-02347	7566 S COWAN AVE	90045	11	102B165   583	4110015048	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2013 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	33.97385	-118.40496	PHOTOVOLTAIC SYSTEM FOR A SINGLE FAMILY SINGLE STORY DWELLING. TOTAL SYSTEM SIZE OF 3.67KW, 17 MODULES. USING SOLAR PANEL REC 245 PE, MICROINVERTER ENPHASE M215-60-2LL-S22.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63373	15041-20000-42277	14117 W HERRON ST	91342	7	222B153   676	2508012019	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Expired	01/18/2018 12:00:00 AM	ADDRESS	34.30246	-118.44098	Plan check for PV roof monted system. System size: 6.0kWac with 22 modules and 1 inverter (6.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63374	12041-20000-12648	5445 N BALBOA BLVD	91316	5	174B133   791	2258027015	(Q)C4-1VLD, (Q)CR-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/01/2012 12:00:00 AM	09/12/2012 12:00:00 AM		Permit Finaled	12/14/2012 12:00:00 AM	ADDRESS	34.16983	-118.50129	NEW TENANT IMPROVEMENT INSIDE AN EXISTING BUILDING CONSISTING OF A COMPLETE 1ST FLOOR ALTERATION AND PARTIAL 2ND FLOOR ALTERATION; REPLACE STAIRS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63375	17041-20000-38937	7831 N GENESTA AVE	91406	6	189B133   677	2204019005	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.21306	-118.50417	0$ permit fees due to senate bill 1222PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 21.12 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63376	10041-20001-23313	10960 W WILSHIRE BLVD 15,19,21	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM			PC Approved	01/12/2011 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check only. Plan check T24 Energy (general/emergency) lighting for 15th, 19th, 21st floor corridors. Replacing existing light fixtures on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63377	19041-20000-06148	17437 W TARZANA ST	91316	5	168B129    38	2290004033	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.16042	-118.51301	Plan check for PV roof mounted system, PV system size: 18.98KW DC, 16.13KW AC with 52 PV Modules and 2 inverters(11.4KW and 7.6KW), 125A sub panel connected to 400A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63378	18041-10000-05112	2173 E 99TH PL Site Light	90002	15	093A217   176	6046019930	OS(UV), R3(UV), RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	33.94734	-118.23366	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK INLCUDES OUTDOOR LIGHTING TO A PLAZA  WITH MULTIPLE BUILDINGS AND PARKING LOT UNDER THE SAME MANAGEMENT. TOTAL SQ. FT. 236,820.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63379	18041-20000-29074	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.12626	-118.21412	Plan check for Medium Voltage interception and extension of existing 5kV feeder, installation of new 75kVA transformer, new 5kV LIS and new distribution panelboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63380	19041-10000-11967	1125 S CRENSHAW BLVD	90019	10	129B189   236	5082026027	C2-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Issued	04/03/2019 12:00:00 AM	ADDRESS	34.05233	-118.32448	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63381	14041-10001-34279	1900 N SAN PEDRO ST	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM			PC Approved	01/14/2015 12:00:00 AM	PIN	33.74647892	-118.27942177	(((1/14/2015- CHANGES MADE TO APPROVED SET. INPUTTING SPLICE BOX TO EXTEND EXISTING CONDUCTOR. INSULATION AND GROUND SHIELDING SHALL BE MAINTAINED. ALSO CHANGED CONDUCTOR SIZES. SCOPE OF WORK HAS BEEN CLOUDED)))Plan check for power. Temporary installationof MVsubstation to power equipment to clean soil which was the site of a tank farm.Was already permited with 14041-40000-31136.{{{POWER EQUIPMENT FOR DIRT REMEDIATION (BERTH 118-120)}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63382	17041-20000-02535	5505 N BONNER AVE	91601	2	174B173  1265	2350005015	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			01/25/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.17022	-118.3742	Plan check for power and energy. Project site is a new 5-story, 32-unit apartment building. Work includes a new 1,200-amp service and a total lighting area of 25,425 sq. ft.Note: Building application has been generated under 16010-20000-00131	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63383	18041-20000-16255	1520 W JAMES M. WOOD BLVD	90015	1	130-5A205 328	5137004029	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.05009	-118.27201	Plan check for PV roof mounted system on commercial building, System size: 20kWac with 71 modules and 2 inverters(10kW) connected to 800A panelboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63384	16041-20000-18161	601 W 5TH ST #230	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Title 24 only in existing space T.I. Total area: 1,554 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63385	11041-10000-07219	811 W WILSHIRE BLVD Ste # 2000	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM			PC Approved	04/12/2011 12:00:00 AM	ADDRESS	34.04973	-118.2584	T.I.  SUITE # 2000 OF A HIGH RISE BUILDING.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63386	18041-20003-32273	3070 W LOS FELIZ BLVD	90039	13	157-5A207 257	5435017019	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.12455	-118.26614	9/12/19changes to an approved set delta 3 only. changes to lighting fixtures and title-24. Addition of new lighting in second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63387	14041-10001-35145	158 N CARMELINA AVE	90049	11	132B141   270	4405005013	RS-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	34.05937	-118.4824	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: YINGLI YL255P-29b(2) INVERTERS: ABB PV1-3.6-OUTD-S-US-Z-A & PV1-3.0-OUTD-S-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63388	19041-10000-29911	555 S FLOWER ST 26TH FLR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	PLAN CHECK FOR ENERGY ONLY, INTERIOR OFFICE TI WITH NEW LIGHTING AND CIRCUITS TO THE 26TH FLOOR. TOTAL SQ. FT. 21306.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63389	11041-10000-26154	2101 S SAWTELLE BLVD	90025	11	126B153   909	4260002029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.03929	-118.44248	T.I. to an Existing restaurant.  Change of lighting.  PLAN CHECK ONLY for Energy. with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63390	18041-20000-30476	21650 W OXNARD ST 22nd flr	91367	3	177B105    83	2146006042	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti to an existing commercial building (high rise) adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63391	19041-10000-28265	4551 S GLENCOE AVE #155	90292	11	105B153   615	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	33.9844	-118.43407	ENERGY PLAN CHECK ONLY FOR INTERIOR OFFICE REMODEL TO EXISTING OFFICE. AREA OF SCOPE 3,065SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63392	16041-10005-04795	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	34.0631	-118.36086	VOID per applicant request. PC for temporary emergency lighting per inspectors request, all future TI will require a complete plan check All changes are under delta 44.Note: This is an empty space and is not open to public, it is only accesible to the owner and used to show to future possible tennats. B# 13014-10000-03762	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63393	14041-10002-29653	211 S LA BREA AVE 211-211 1/2	90036	5	138B181  1307	5513022012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.07066	-118.34433	TI on (N) commercial build. under core & shell. Added New Demising wall partition to create two retail tenant spaces. NO Occupied Tenant at this moment. PC for Energy  (indoor) only.Ref.: 14041-10001-29653Buil. App.# 16016-10000-05239	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63394	17041-10000-32470	700 S FLOWER ST 30TH FLOOR	90017	14	129A209   259	5144010401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLAN CHECK FOR T24 ONLY, INTERIOR TENANT IMPROVEMENT ON ENTIRE 30TH FLOOR, EXCLUDING RESTROOMS, ELECTRICAL ROOMS, ELEVATOR LOBBY. TOTAL AREA 19910 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63395	17041-10000-20015	8759 W SKYLINE DR	90046	4	153B169   364	5564009013	RE15-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	08/24/2019 12:00:00 AM	ADDRESS	34.11539	-118.38572	PC for new (2)Tesla Powerwall2(13.2KW) , backup panel connecting to existing house panel and upgrading to 225A main panel with 175A main breaker. Inspection to verify that breaker disconnect is installed at tesla gateway.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63396	18041-10000-26107	888 S FIGUEROA ST Suite #370	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI IN AN EXISTING OFFICE AREA IN SUITE #370.T-24 ENERGY CALCS ONLY.BLDG PERMIT: 18016-10000-20507	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63397	16041-10000-03556	401 E M ST	90744	15	036B209   611	7422017900	OS-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Expired	03/01/2018 12:00:00 AM	ADDRESS	33.78924	-118.25841	INSTALL NEW FIRE ALARM SYSTEM FOR A MUSUME. 107 FA DEVICES. ONE FA  PANEL AND ONE CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63398	18041-20000-08565	20224 W ELKWOOD ST	91306	3	189B113  1034	2107022068	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.2122	-118.57392	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (1) inverter and (27) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63399	12041-10001-25823	2630 N HYPERION AVE 101	90039	4	150A205    96	5432001016	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	PIN	34.10627783	-118.27222119	12041-10001-25823THIS IS SUPPLAMENTAL PC FOR REDESIGN OF LIGHTING FIXTURES. PC FOR ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. Plan check for energy and emergency lighting. Restaurant. 1183sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63400	15041-10001-00849	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM			PC Approved	05/01/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Change to an approved set by modifying the lighting floor plan. All changes are under delta-A only(((Office TI by remodeling an existing westfield security office in topanga mall.PLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63401	19041-20000-52461	9920 N BALBOA BLVD A-D	91325	12	201B133   670	2685007017	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/10/2020 12:00:00 AM		Permit Finaled	03/09/2021 12:00:00 AM	ADDRESS	34.25097	-118.50219	PV3.  Install 129.6 KW DC/117.5 KW AC CEC roof mounted feed-in-tariff PV system.  (324) modules with (3) 33.3 KW inverter, and (1) 200A panel, and service disconnect.$0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63402	14041-20000-17123	10526 W DUBNOFF WAY BLDG J	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.18656	-118.36106	"T.I. to existing building J.  Install branch circuits and lighting.  Plan check for power and energy.Note: Applicant will submit approved plans within 3 days.  See ""Application Comment"" for info."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63403	19041-10000-07821	718 E ROSE AVE	90291	11	111B145   725	4240018044	C2-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Apartment			03/05/2019 12:00:00 AM	07/02/2020 12:00:00 AM		Permit Finaled	03/31/2022 12:00:00 AM	ADDRESS	34.00061	-118.469	PLAN CHECK FOR POWER AND ENERGY INSTALL NEW 1600 AMP 120/208 3 PHASE SERVICE. SCOPE OF WORK INCLUDES PANELS, EQUIPMENTS AND LIGHTING. FIRE ALARM VARIANCE GRANTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63404	15041-20000-39691	8932 N WOODMAN AVE 2nd Floor	91331	6	195B153   373	2640016027	P-1VL, [Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM			PC Info Complete	01/06/2016 12:00:00 AM	ADDRESS	34.23211	-118.43779	TI on a Medical facility OSHPD-3, scope on the 2nd floor only. New 400A Bus panel, total area: 4,243sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63405	14041-20000-22128	920 W BLOOM WALK	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.01996	-118.28938	Plan check for power and energy. New life safety equipment. USC Seaver Science Center building 5th floor remodel/TI. 3,731 sqft. Fees provided by applicant, verify during plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63406	18041-10000-11949	1001 S GAYLEY AVE	90024	5	132B149    43	4363025012	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Issued	07/30/2018 12:00:00 AM	ADDRESS	34.06169	-118.44797	PLAN CHECK FOR TI TO AN EXISTING RESTAURANT. TOTAL AFFECTED AREA 1606 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63407	19041-10000-42889	7201 S SAN PEDRO ST	90003	9	102B205   874	6022009029	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2396.01	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	33.97452	-118.26972	PLAN CHECK FOR THE INSTALLATION OF   2 EA 200A PANELBOARDS ( MARKET AND FUEL DISPENSERS -18041-10000-16739 AND 19041-10000-07561 ) AND 1 EA 100A PANELBOARD FOR EXISTING RETAIL STORE. THE SERVICE IS EXISTING; THE SWBD IS UNDER THE PERMIT FOR THE MARKET; THE NEW PANELBORDS ARE TO REPLACE THE EXISTING PANELBOARDS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63408	15041-20000-10564	4761 N HASKELL AVE	91436	5	168B141   985	2261009028	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.1568	-118.47514	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 9kW (3+6). Ungrounded system. (33) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63409	15041-10001-25204	7511 N LASAINE AVE	91406	6	186B133   416	2202014030	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.20683	-118.51102	CHANGE IN SYSTEM. NOW USING 17 MODULES IN TOTAL CONNECTED TO 3 STRINGS.  INVERTER IS 5KW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63410	19041-10000-18661	8401 N VAN NUYS BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	12/22/2020 12:00:00 AM	ADDRESS	34.22308	-118.44896	TI IN AN EXISTING RETAIL (T-MOBILE) STORE. INSTALLING NEW LIGHTS.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63411	10041-10001-25193	8358 W FOOTHILL BLVD	91040	7	204B189    39	2560007003	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	01/03/2011 12:00:00 AM	ADDRESS	34.25953	-118.31549	Revision to the approved plan. Change the lighting & T24 calc. EPC is for T24. ((((((((((((CHANGE OF USE FROM RETAIL TO BAKERY AND PROVIDE (N) ADA RESTROOM;PLAN CHK IS FOR TITLE 24)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63412	11041-10000-22719	2440 N VERMONT AVE	90027	4	153B197   193	5588028010	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1891.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.11537	-118.28988	INSTALLING  A 15.84KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63413	12041-10000-17592	22700 W SHERMAN WAY	91307	3	183B097   111	2024019005	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	02/12/2013 12:00:00 AM	ADDRESS	34.20071	-118.62196	New 20kw photovoltaic system in the carport of a church parking lot.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63414	19041-10000-04478	250 W CENTER WAY APM Center-Station	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Issued	01/10/2020 12:00:00 AM	ADDRESS	33.94439	-118.40399	NEW CENTRAL TERMINAL AREA (CTA) CENTER STATION FOR LAX AUTOMATED PEOPLE MOVER. INCLUDING APM STATION, LIGHTING, HVAC & EMERGENCY POWER IN LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63415	15041-10001-17154	5631 S MESMER AVE	90230	11	105B165   320	4220014031	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	33.9854	-118.40058	11-17-2015Changes to an approved set, note changes on delta 1. Changes include fixture type, and receptacle load. (((TI-24 TO AN (E) COMMERCIAL BUILDING, ADDING NEW LIGHTING. PC FOR ENRGY ONLY, TOTAL SQ FT. 7122)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63416	18041-10000-30241	127 W MANCHESTER AVE	90003	9	097-5A203 305	6040011027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	33.96025	-118.27497	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63417	13041-10000-03079	657 W REDONDO BEACH BLVD 1-6	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	33.89279	-118.28709	CHANGE OF USE FROM PREVIOUS OPEN OFFICE SPACE TO NEW 6 TENANT RETAIL AND RESTARAUNT USE. RECONSTRUCTION OF ONE BUILDING TO 6 INDIVIDUAL TENANTS. SCOPE OF WORK INCLUDES PC FOR POWER FOR THE UNITS AND ENERGY FOR 1 OF THE UNITS. PER SUPERVISOR REQUEST, BACK ROOM PLAN CHECK REQUIRED. PC FOR ENERGY TOTAL OF 1177 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63418	13041-10000-09624	3013 N WASHINGTON BLVD	90292	11	108B149  1470	4229007085	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			PC Approved	04/15/2013 12:00:00 AM	ADDRESS	33.98911	-118.45009	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. EMERGENCY LIGHTING IS NOT IN SCOPE OF WORK. SCOPE OF WORK: LIGHTS IN EXITING OFFICE, STAIRS, BATHROOM AND ADMINISTRATION ROOM.  PERMIT PULLED UNDER APPLICATION NUMBER 13041-30000-03752. ***********************************************************13041-30000-03752 DESCRIPTION: ADDING 8 CAN LIGHTS, 4 SURFACE MOUNT, 4 RECEPTACLES, AND RELOCATE 3 LIGHT SWITCHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63419	13041-10000-04744	1884 S WESTWOOD BLVD	90025	5	129B153   682	4321001013	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.04852	-118.43551	((((EXPRESS PERMIT WAS PULLED BEFORE PLAN CHECK. EXPRESS PERMIT APPLICATION#: 12041-10000-30983))))))T24 for a restaurant (single-story building).  1582 sq ft.  31 person max occupancy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63420	15041-10000-14932	13317 W ALMETZ ST	91342	7	231B157   197	2582036035	RS-1	North Valley	Sylmar	Sylmar	YES	1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.32746	-118.42236	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 7.68KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63421	11041-10000-25376	9301 N TAMPA AVE Space 212	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I. to an existing retail space in the Northridge Mall.  Space 212, two-levels.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63422	15041-20000-18151	10207 N JANETTA WAY	91040	7	204B177    88	2542031026	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.25558	-118.36607	Plan check for PV roof mounted system. System size: 9.0kW with 30 modules and microinveters(ABB Micro-0.3-I-outd-us-240)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63423	19041-10000-14655	1003 E 4TH PL 7TH FLR	90013	14	127-5A217  55	5163018002	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	34.04219	-118.23383	FIRST TIME TENANT TO A CORE AND SHELL. PROPOSED INTERIOR TI OF 7TH FLOOR; SCOPE OF WORK INCLUDES NEW PANELS, TRANSFORMER, LIGHTING AND POWER. TOTAL SQ. FT. 17636.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63424	15041-20000-39253	8312 W 3RD ST	90048	5	138B173   896	5511031037	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.07258	-118.37052	Plan check for Title 24 only restaurant in existing space. Total area: 1,000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63425	18041-20001-26123	8700 W BURTON WAY 1-30	90048	5	138B169   722	4334015035	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.07196	-118.38193	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 48.47 kWdc/43.5 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (131) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63426	15041-20000-03270	1122 S GAYLEY AVE # 101	90024	5	132B149   108	4363023030	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Issued	07/20/2015 12:00:00 AM	ADDRESS	34.05976	-118.44586	PLANCHECK FOR POWER AND ENERGY FOR A  RESTAURANT: LE PAIN QUOTIDIEN,  2,235 S.F. FIRST TIME TENANT PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63427	16041-20001-23923	411 S CATALINA ST	90020	10	135B197   557	5502012021	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.06673	-118.29556	RSES expedited plan check feePV2.  Install 59.8 kW DC roof-mounted PV system.  (176) modules with (4) 10kW transformerless central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63428	15041-10003-14888	1100 S HILL ST	90015	14	126A209   128	5139019034	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			10/03/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.03989	-118.25984	"Changes to an approved set of plans. All changes are clouded under delta 22. Changes include revising available fault currents on the the switchboards, relocate panel ""ELEV"" on the single line diagram and floor plans, Changing series rated breaker types, and adding a new panelboard. PC ONLY.Note: Available fault current is calculated from the busducts on the DWP vault."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63429	16041-10000-11671	2980 N ALLESANDRO ST	90039	13	150B213   731	5442024030	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.10564	-118.2445	NEW FIRE ALARM SYSTEM WITH 155 FA DEVICES AND 1 FA PANEL ALONG WITH 1 ANNUNCIATOR AND ONE CONTROL PANEL FOR 40 unit apartment building. live work. retail first level. mix use building. plan.F.A conduit only is filed on 4/4/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63430	14041-10000-16776	16962 W OAK VIEW DR	91436	5	165B133    72	2289030006	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.1521	-118.5025	Addition of 2 solar modules to installed rooftop system.  New total system size = 7.25 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63431	11041-20000-26423	8023 W BEVERLY BLVD Unit 6	90048	5	138B177   391	5527034025	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	34.07625	-118.3645	T-24 for remodeled tenant space.  Install new lights and receptacles to existing circuits.  No new circuits installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63432	15041-10002-21032	2239 S PONTIUS AVE	90064	5	126B153  1005	4322024039	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/05/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	08/26/2015 12:00:00 AM	ADDRESS	34.03869	-118.43767	((8/5/2015- CHANGES MADE TO APPROVED SET BY AI. CHANGED OUT ALL THE INVERTERS TO 11.4 KW INVERTERS)))PV2, INSTALL 3900 KWDC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING TIE WITH THE MAIN SERVICE PANEL. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222.(150) MODULES: KYOCERA KD260GX-LFB2 260W(4) INVERTERS : SOLAREDGE SSE9K-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63433	16041-10000-24385	5700 S SAN PEDRO ST	90011	9	108B205   945	5101008007	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	33.9905	-118.26998	PC FOR ENERGY ONLY. REPLAEMENT OF HID FIXTURES WITH NEW LED FIXTURES. TOTAL AREA 46686 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63434	15041-20001-15397	1331 E 7TH ST	90021	14	124-5A215  32	5147035002	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.0363	-118.24023	Modifications to approved set.  Additional devices: corridor smoke detectors and pull stations.  Revision of horn-strobes to speaker-strobes.  (((Fire alarm for 87 unit apartment. 1 FACP, 10 POWER SUPPLIES AND 266 DEVICES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63435	18041-10001-11394	10250 W SANTA MONICA BLVD #2395	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Approved	08/31/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE DOWNSIZING AIC RATING FROM 35KAIC TO 14KAIC WITH A FAULT CURRENT OF 13KAICORIGINAL PERMIT Interior remodel of  first tenant take out tea shop ""Red Straw"". Scope of work include new interior and exterior alterations."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63436	19041-10000-23119	1441 W 244TH ST	90710	15	039B193   236	7439017005	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	33.80344	-118.30257	PV 1, ROOF MOUNTED SOLAR SYSTEM USING (16)MICRO INVERTERS. TOTAL SYSTEM SIZE IS 5.04 KWDC AND 4KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63437	13041-10000-15162	18251 W ROSCOE BLVD	91325	12	192B125   630	2786015018	(Q)CR-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.22097	-118.53126	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. TENANT IMPROVEMENT FOR OFFICE AND RETAIL IN A PHARMACY. NO MEDICAL EQUIPMENT OR PATIENT CARE AREAS. 483 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63438	17041-10000-03199	20050 S VERMONT AVE	90502	15	057B197   154	7351033062	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	33.84838	-118.29024	FULL PC FOR POWER AND ENERGY FOR A 2 STORY GYM/CLASSROOM ADDITION TO AN EXISTING CHURCH. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, NEW LIGHTS, AND RECEPTACLES. A-OCCUPANT LOAD > 100.  TOTAL AFFECTED AREA IS 12444 SQ. FT. B#17014-10000-00042	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63439	09041-10002-23012	10250 W SANTA MONICA BLVD # 59	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM			PC Approved	02/25/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Delta 5 modification only.  No change to the lighting that will change the T24 lighting plan. No change to emergency lighting.  See original application for permit.  PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCTY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63440	12041-10000-21212	345 S ALEXANDRIA AVE	90020	14, 4	135B197  1268	5502003020		Central				2119.10	Electrical	Electrical	Public Safety Only			09/07/2012 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Expired	02/04/2015 12:00:00 AM	ADDRESS	34.06775	-118.29817	Replace fire alarm control unit and devices. (302 existing devices)PARCEL RANGE FROM 5502003020 - 5502003123	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63441	19041-10000-48653	5333 W JEFFERSON BLVD	90016	10	120B177   646	5043023025	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	04/02/2020 12:00:00 AM	PIN	34.0260947	-118.36199885	Full plan check for Installation of a 7,142 sq ft new freezer and combining one existing cooler and one existing freezer to create one cooler in an existing 98,408 sq ft wholesale market. Existing service size 2000A, 480/277V, 3phase. Note this project covers two phases, any sheets marked with the letter A is phase one, and sheets marked with the letter B is phase two. Note phase one was orginally submitted under 19041-10K-05107, but that appliaction will be withdrawn. 19041-10k-48653 will cover all work and permit fees.  A 1,211 sq ft screened concrete refigeration equipment pad will be installed at the exterior rear of the existing bldg for equipmetn associated with the new freezer. Scope will also inlcude relocation of existing front door, and modifications to front end offices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63442	15041-20000-09444	11146 W VANOWEN ST	91606	2	180B173    35	2319013014	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	PIN	34.19358386	-118.37399427	PV1 SFD. TOTAL SYSTEM SIZE 3.5KW AC USING SINGLE TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. TOTAL OF 14 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63443	16041-10000-23291	1245 W WILSHIRE BLVD 170	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM			PC Info Complete	09/16/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	FULL PC FOR POWER AND ENERGY.  MEDICAL OFFICE TI (OSHPD 3) WITHIN AN EXISTING MEDICAL OFFICE BUILDING. FIRST TIME TENANT.  SCOPE OF WORK INCLUDES ONE NEW 225A SUBPANEL, NEW IMAGING EQUIPMENT, NEW RECEPTACLES, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 1139 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63444	18041-10000-44459	4029 W WILSHIRE BLVD	90010	4	132B189    29	5504017901	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.06188	-118.3155	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63445	16041-20001-43880	3411 E 15TH ST	90023	14	117A225   110	5192013032	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.01586	-118.20638	01/18/2017 Changes to an approved set of plans. Changes have been made to the single line diagram on how panel boards are being fed.*****Previous Work Description*****Plan check for power only. New 600A service for existing commercial building. New new loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63446	16041-10000-03327	1212 S FLOWER ST	90015	14	126A207    34	5138026030	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM			PC Info Complete	02/09/2016 12:00:00 AM	ADDRESS	34.04113	-118.26555	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE BASEMENT LEVEL. SCOPE INCLUDES ADDING NEW LIGHTS TO A GYM. TOTAL AFFECTED AREA IS 6157 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63447	11041-10000-13022	1031 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM	09/07/2011 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	PIN	34.02400284	-118.2895744	99,000 sqft USC Student Health building.  Applicant wants plan check for shell only.  Building is 5 story above grade and 1 basement level.  Title 24 includes stairways and outdoor lighting only.   Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63448	16041-10000-17512	2476 S OVERLAND AVE	90064	5	126B157   886	4255002027	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	06/02/2016 12:00:00 AM	ADDRESS	34.0406	-118.42365	Energy plan check for office T.I Scope of work includes indoor and outdoor. Total area is 314 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63449	14041-10002-28878	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	Changes to approved set.  new lighting fixtures and new lighting layout.  Relocating connections throughout for varous distribution boards.  New power layout in corridor areas.This project is phase 4 of Westfield Century City which includes level 1 and level 2 core and shell for tenant spaces and above ground parking garage on levels 3 through 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63450	18041-20000-11064	330 S ALAMEDA ST	90013	14	127-5A215 134	5163010007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.04394	-118.23787	(N) corridor in commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63451	14041-10000-18645	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC FOR POWER AND ENERGY. TI.RESTURANT. TOTAL AREA 2867 SQ FT.        (((((((((((( M.Z.  a variance is filed for meter reading or option is given to engineer to produce approved master plans in lieu of meter readings.  10-10-14))))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63452	18041-10000-38725	7528 W 82ND ST	90293	11	096B157   241	4114017021	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	33.96202	-118.42919	NEW ROOF MOUNTED 9.3KW PV SYSTEM WITH 31 PV PANELS ON A SINGLE FAMILY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63453	13041-10000-27450	314 E 8TH ST	90014	14	126A211    89	5145012027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/03/2013 12:00:00 AM	ADDRESS	34.0409	-118.25154	TITLE 24 ENERGY PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES. INSTALL NEW FLUORESCENT FIXTURES. 1102 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63454	19041-20000-02907	1916 N SERRANO AVE	90027	4	150A193   118	5589001014	RE9-1	Central	Hollywood	Los Feliz		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.10586	-118.30702	PC FOR NEW ROOFTOP PV FOR EXISTING SFD. SYSTEM IS 10KW AC, SCOPE OF WORK INCLUDES (36) 360W PV MODULES WITH OPTIMIZERS AND (1) 10KW AC CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63455	13041-10001-22046	800 N AVENUE 63	90042	14	156A233   250	5486029001	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM			Reviewed by Supervisor	08/23/2013 12:00:00 AM	ADDRESS	34.12155	-118.17852	[][]EXPEDITE PER APPLICANT REQUEST[][][][PV1 ROOF-MOUNTED INSTALLATION; 1.5 KW SYSTEM WITH:(6) MODULES: PHONO PS250P(6) MICROINVERTERS: ENPHASE M215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63456	16041-10001-24829	4371 E VALLEY BLVD	90032	14	135A229    71	5215014001	[Q]CM-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM			Reviewed by Supervisor	07/21/2016 12:00:00 AM	ADDRESS	34.06339	-118.19021	Expedited plansChange to approved set of plans.Rearranging location of solar modules.  ((($0 final fee per senate bill 1222.PV2, rooftop solar insrallation 86.4 kW AC system(296) RENASOLA JC310M-24(6) SE14.4KUS(1) 300A subpanel no fees due to senate bill 2012)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63457	19041-20000-50245	588 W CYPRESS AVE	90065	1	144A219   322	5446007027	RD2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.08785	-118.22174	PV2 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 2.22 KW DC/1.74 KW AC. SCOPE OF WORK CONSISTS OF (6) PV MODULES WITH MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63458	13041-20002-30880	3155 N DONA MARTA DR	91604	2	159B173   649	2380022014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	02/07/2014 12:00:00 AM	ADDRESS	34.12842	-118.37719	"PC FOR CHANGE IN LOCATION OF SERVICE AND AC DISCONNECT. $0 PLAN CHECK FEE DUE TO SENATE BILL 1222 FROM 2012.ENSURE PV OUTPUT TO LOAD CENTER CONTAINS 9#8 IN 1"" CONDUIT. DUE TO TEMPERATURE DERATING FACTORS"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63459	17041-10000-32962	800 S FIGUEROA ST 8TH FLR	90017	14	129A207   158	5144021039	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.04771	-118.26116	PC FOR TI TO 8TH FLOOR. PC FOR T24 ENERGY ONLY FOR LIGHTING UPGRADES. OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63460	17041-20000-01490	5656 N BABBITT AVE	91316	5	174B133   403	2255014016	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.17409	-118.50914	pv1install roof mounted pv system sized 5.4kw interconected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63461	14041-10000-03646	433 S SPRING ST	90013	14	129A211    59	5149024016	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM			Verifications in Progress	03/26/2015 12:00:00 AM	ADDRESS	34.04822	-118.24907	pc for power and energy. LIVE-WORK (E) HIGH RISE 13? STORY 228UNITS APT. GROUND FLOOR COMMERCIAl space and two basement levels with parking. 71 typical units13014-10000-05238 description: CHANGE OF USE OF AN EXISTING 312,658 SQ FT  11 STORY BUILDING W/BASEMENT AND ROOF DECK INTO JOINT LIVING AND WORK QUARTERS PER THE ADAPTIVE REUSE ORDINANCE (TOTAL OFF 216 UNITS) ADDITION AT 4TH,5TH, AND 11TH FLOOR, EXTEND THE ROOF DECK TO CREATE ADDITIONAL AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63462	17041-20000-17395	9237 N KENNY CT	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.23853	-118.45932	Plan check for a PV1 roof-mounted PV system. System size is 4 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63463	14041-20000-21604	16254 W LOS ALIMOS ST	91344	12	207B137   381	2680008023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.26547	-118.48661	Roof mounted PV system with system size 8.16KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63464	15041-10000-14213	920 S CROCKER ST #105 & 106	90021	14	124-5A211 152	5132002045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.03569	-118.24958	CONVERSION OF TWO TENANT SPACES INTO ONE TENANT SPACEPLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63465	14041-10000-28765	222 S HILL ST	90012	14	130-5A211  27	5149009023	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Expired	11/10/2016 12:00:00 AM	ADDRESS	34.05244	-118.24815	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 PANEL AND 150 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63466	12041-10000-20726	770 W WILSHIRE BLVD	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	01/31/2013 12:00:00 AM	ADDRESS	34.04914	-118.25811	TI IN AN EXISTING COMMERCIAL BUILDING. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63467	15041-10001-03577	4801 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM			Reviewed by Supervisor	09/17/2015 12:00:00 AM	ADDRESS	34.04683	-118.34063	((8/27/2015- ORIGINAL APPROVED SET LOST. PLAN TO BE VERIFIED AGAINST APPROVED SET.))PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-10000-03577.  THIS IS PLAN CHECK ONLY.Full plan check for a commercial building T.I (2-story with a basement furniture retail store).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63468	15041-20000-25417	10201 N MOUNTAIR AVE	91042	7	204B197   958	2558023071	RD1.5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.2542	-118.29329	Installation of new fire alarm system for new 10 unit apartment building.  Total system size = 69 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63469	14041-20000-32617	13321 W VENTURA BLVD UNIT E	91423	4	165B157   794	2360011028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Expired	12/16/2016 12:00:00 AM	ADDRESS	34.14687	-118.42328	PLANCHECK FOR T24 ENERGY.   TI TO BEAUTY SHOP.  1320 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63470	14041-20000-17557	16633 W VENTURA BLVD	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.15823	-118.49571	pc for T24 energy only. new lighting for existing parking garage. This is fixture for fixture exhange only. no control changes, no new wiring except lobby. pc for T24 energy calcs only for garage and calcs and controls for lobby.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63471	15041-10000-01642	2223 E DAMON ST	90021	14	121-5A217  47	5166021007	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.02877	-118.23287	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 4840 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63472	14041-20000-15561	1492 W SUNSET BLVD	90026	1	139-5A209 292	5405001026	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Apartment			06/11/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	34.07547	-118.255	Plan check for Tittle 24 only on a new 4 stories apartment garage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63473	17041-10000-02862	9163 N KEWEN AVE	91352	6	198B165   343	2629014075	RS-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Issued	01/29/2024 12:00:00 AM	ADDRESS	34.2358	-118.39935	PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM FOR SINGLE FAMILY DWILLINGSYSTEM SIZE = 7.6KVA, USING 2 INERTERS(ABB-3.8-OUTD--S-US) WITH 27 MODULES (SUNPOWER-SPR327NE-WHT-D).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63474	19041-20000-21265	6060 W CENTER DR 4TH FLR	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	33.97602	-118.39073	ENERGY ONLY T24 PLAN CHECK FOR TI TO EXISTING HIGH RISE OFFICE SPACE 4TH FLOOR. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 8,288 SFB#19016-10000-15559	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63475	11041-10000-24662	21263 W ERWIN ST	91367	3	177B105    20	2149001029	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/17/2011 12:00:00 AM			Corrections Issued	11/17/2011 12:00:00 AM	ADDRESS	34.18302	-118.59459	T.I. to an existing medical office.  Per applicant this is for group therapy and offices only.  Full plan check may be required subject to inspection.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63476	14041-20001-27521	7170 W SENALDA ROAD	90068	4	153B181   145	5572035012	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM			PC Approved	01/07/2015 12:00:00 AM	ADDRESS	34.11669	-118.34607	PV1.  Install 9.6 kW roof-mounted, utility-interactive PV system.  Microinverters.  400A-rated service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63477	13041-10000-22492	4940 N PASO ROBLES AVE	91316	5	168B133    24	2258019001	(T)(Q)R3-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Apartment			08/19/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.16074	-118.50202	fire alarm system. apartment. total of 215 devices.4 stories with one sub garage, new panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63478	15041-10000-12387	345 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM			Reviewed by Supervisor	05/04/2015 12:00:00 AM	ADDRESS	34.05424	-118.25562	TI, NEW TENANT IN (E) BUILDING. PC FOR POWER AND ENERGY. TOTAL SQ. FT. 1881	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63479	15041-20001-20305	7950 W SUNSET BLVD 102	90046	4	147B177  1021	5554003055	(Q)RAS4-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			09/18/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.09777	-118.36322	PC FOR POWER AND RESTAMP FOR ENERGY. CHANGE OF USE TO FITNESS STUDIO. PC FOR NEW 600A PANEL AND ASSOCIATED LOADS. PER INSPECTOR FIRST TIME OCCUPANCY.SUPPLEMENTAL PERMIT WILL BE ISSUED FOR 600A PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63480	13041-10000-04708	3800 N EUREKA DR	91604	2	162B173   631	2378012004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	ADDRESS	34.1392	-118.37295	PV1 2 STORY SINGLE FAMILY HOUSE.  TRANSFORMLESS INVERTERS.  11.772 KW SYSTEM INSTALLATION.  {INVERTER: POWER ONE AURORA (1) PVI-6000-TL AND (1) PVI-5000-TL} {36 MODULES:  SUNPOWER SPR-327NE-WHT-D}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63481	18041-20000-38201	7000 W 3RD ST 2ND FLOOR	90048	5	138B177   793	5511027028	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.07135	-118.36168	ti to an existing commercial building adding new lighting new controls to existing panels.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63482	18041-20000-34333	4541 N WINNETKA CIR	91364	3	168B113   447	2174002026	RA-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Issued	09/07/2018 12:00:00 AM	ADDRESS	34.15424	-118.57151	Plan check for PV roof mounted system, system size: 3.0kW with 11 modules and 1 inverter(3.0kW) center feed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63483	15041-10000-18744	12468 W OSPREY LANE	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	33.97899	-118.41015	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'B'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'B' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63484	10041-20000-02885	17220 W VENTURA BLVD	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1VL, C2-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	04/27/2010 12:00:00 AM		Permit Finaled	09/08/2010 12:00:00 AM	ADDRESS	34.16046	-118.50839	T.I FOR EXISTING COMMRCIAL RETAIL FOR MICHAEL'S STORE. VARIENCE WILL FILE TO SEPARATE FIREALARM FROM THIS PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63485	15041-10000-04172	113 S LA BREA AVE 1st Floor	90036	5	138B181   895	5513019042	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.07317	-118.34429	Full plan check for first time tenant, (Tenant space being developed by owner)  Emergency lighting not required due to occupant load of space - emergency lighting provided for added protection - OK per Nabil Maalouf.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63486	15041-20001-18408	6510 N NAGLE AVE	91401	2	180B157   689	2329025016	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	07/08/2015 12:00:00 AM	ADDRESS	34.1887	-118.42348	ECPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 12.2KW AC USING TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. TOTAL OF 41 MODULES INSTALLED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63487	12041-20000-02999	2829 W SUNSET BLVD	90026	13	141A205    24	5402001037	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.08236	-118.27226	T.I. to an existing building.  Install indoor general/emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63488	12041-20000-06949	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	34.15886	-118.50032	Change of use from office to fitness facility.  Install new 800A panel, and other subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63489	18041-10000-25564	9240 N RESEDA BLVD	91324	12	198B125   221	2764012003	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.23842	-118.53588	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63490	19041-20000-22184	9570 W HIDDEN VALLEY ROAD	90210	4	156B165   249	4387007006	RE20-1	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.12046	-118.40493	Install 54 kWh / 20 kW rated energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63491	15041-20001-06576	24550 W GARDENSTONE LANE	91307	12	183B085    66	2031006071	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	34.20021	-118.65972	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derate main to 150A.System size: 12kW (6+6). Ungrounded system. (51) 260W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63492	19041-20000-10650	6033 W CENTURY BLVD Ste 1200	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	33.94572	-118.38954	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63493	18041-20000-07813	20649 W CHESTNUT CIR (#265)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29363	-118.58422	Plan check for a PV1 roof-mounted PV system. System size is 2.9 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63494	16041-10002-18367	4048 N BECK AVE	91604	2	162B169   390	2368023052	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.14125	-118.38312	Changes to approved set of plans. Rearrangement of solar panels and upgrading the main service panel to 400 Amps. ((((  *Permit Fee $0 due per CA Senate Bill 1222.PV1 plan check for new solar system. AC system size 16 kW. 48 Canadian Solar modules. 2 SMA SB8000TL-US inverters.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63495	10041-10000-13177	1111 S HOPE ST	90015	9	127-5A207 262	5138014112	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	34.0422	-118.26337	title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63496	14041-10000-00111	11150 W SANTA MONICA BLVD # 100	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLANCHECK FOR T24 ENERGY ONLY. OCCUPANT LOAD <100. TENANT IMPROVEMENT FOR MARKET CAFE .1817 SQFT, EMERGENCY LIGHTING. HIGH RISE. WORK ON SUITE 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63497	16041-20000-27187	5533 S EA WAY	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	09/15/2020 12:00:00 AM	ADDRESS	33.97374	-118.42896	New 6 Story Type IA office building over 2-story Type IA subterranean garage.  Core and shell drawings.  Plan check for power and energy.  New 4000A 480Y/277V service with emergency generator and fire pump.  Not a highrise per applicant - verify with building permit.  Building permit filed under 16010-10000-02180.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63498	18041-10000-03180	18350 W ROSCOE BLVD 603	91325	12	192B125   686	2102001015	R4-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	34.22057	-118.53415	PC OF POWER AND ENERGY FOR MEDICAL TI(QUEST DIAGNOSTICS) INTERIOR IN EXISTING MEDICAL OFFICE SPACE IN A HIGH RISE BUILDING. SCOPE INCLUDES NEW PANEL  CIRCUITS  AND EQUIPMENT. TOTAL AFFECTED AREA 3425 SQ.FT B#18016-10000-00722	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63499	17041-10000-35186	1331 N CAHUENGA BLVD	90028	13	147A187   323	5546017014	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM			Verifications in Progress	09/12/2018 12:00:00 AM	ADDRESS	34.09556	-118.32924	PC for rooftop PV solar in commercial building. Installing 529 modules, six inverters, three new load center panels. Total system size is 245kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63500	15041-10000-07259	652 N LA BREA AVE	90036	5	141B181   668	5525017011	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.08313	-118.34386	Plan check for Title 24 only. Project space is existing commercial (Wells Fargo Bank). Total lighting area = 3,210 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63501	13041-10003-20342	1420 S FIGUEROA ST	90015	9	126A205   176	5134009019	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			12/04/2014 12:00:00 AM			PC Approved	12/19/2014 12:00:00 AM	ADDRESS	34.03815	-118.26937	Modifications to approved set.  Change of motor conductor sizes, short circuit protection.  Other miscellaneous changes to wiring on single line feeders.  Delta 6 revisions isolated to sheet E2.SL1 for changes to single line.  original description:pc for power and energy.  METHANE Zone. PROPOSED  193 UNIT APARTMENT AND PARKING GARAGE. 7 STORY (5 LEVELS OF TYPE IIIA APARTMENT OVER 2 LEVELS OF TYPE I , APARTMENT AND PARKING OVER 2 LEVELS OF BASEMENT PARKING.[][][conduit variance filed and paid for on 10/11/2013 under 13041-10000-28450 . pl,10-11-13[][][	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63502	13041-10000-30817	20231 W VIA SANSOVINO	91326	12	219B113   314	2701062029	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.29769	-118.57367	PV1, Install 10.75 kW DC roof-mounted solar array, interconnect with service panel. Multiple inverters: Solaredge SE 6000A-US and Solaredge SE 3800A-US. 43 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63503	11041-10000-12768	601 WORLD WAY parking	90045	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/08/2011 12:00:00 AM	PIN	33.94463112	-118.38247895	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63504	16041-10001-32555	6171 W CENTURY BLVD	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM			PC Approved	11/22/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	11/22/16Changes to an approved set of plans. Changes include relocating the panelboards on the floor plans. Note: Permit will be paid under PCIS#16041-10000-32555	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63505	11041-20000-05581	444 S FLOWER ST #2100	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM			PC Info Complete	03/22/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO EXISTING OFFICE ON PORTION OF 21ST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63506	19041-20000-18114	20836 W PINECONE CIR 32	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.29565	-118.58829	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63507	17041-20001-46469	20146 W HART ST	91306	3	183B113   466	2135033012	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC in Progress	01/06/2018 12:00:00 AM	ADDRESS	34.19732	-118.57284	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system.7.6kW ungrounded pv system. (23) 325W pv modules. (23) 400W power optimizers.(2) 5kW Tesla powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63508	14041-20001-02604	11542 N ACALA AVE	91340	7	213B149   332	2613015033	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM			PC Approved	02/26/2014 12:00:00 AM	ADDRESS	34.27954	-118.45168	(((Expedite Fees)))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63509	15041-10000-13118	9313 W BOLTON ROAD	90034	5	126B169    68	4309012014	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.04514	-118.39248	PV1, INSTALL 4.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES: KYOCERA KU2606XPA(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63510	18041-10000-17139	4608-4610 N EAGLE ROCK BLVD 1-2	90041	14	157-5A221  34	5474003004	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.12763	-118.21748	NEW 600AMP SERVICE IN A 2 STORY MIXED BUILDING.    CORE & SHELL ONLY.  2 COMMERCIAL UNITS ON THE FIRST FLOOR AND 2 APARTMENTS ON THE SECOND FLOOR.<<<<ALL CIRCUITS WILL BE COVERED UNDER FUTURE TI>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63511	16041-20000-19401	3239 N PASADENA AVE Unit B	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	PV2.  Install 5.7 kW DC roof mounted PV system.  (20) modules with (1) 5 kW transformerless inverter with power optimizers.  2 of 3 PV systems proposed for property submitted concurrently.Zoning clearance obtained under 16041-20000-19398	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63512	17041-10000-08414	8910 S CENTRAL AVE	90002	9	096A209   330	6043006016	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.95527	-118.25622	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 9,500 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63513	19041-20000-22315	5330 N MANTON AVE	91367	3	171B093    76	2044011011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.16829	-118.64102	PLAN CHECK FOR NEW 27 KWH ENERGY STORAGE SYSTEM CONSISTING OF (2) 13.5 KWH TESLA POWER WALLS, CONNECTED TO AN EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK ALSO INCLUDES A NEW 225A LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63514	10041-10000-01204	1710 N LAS PALMAS AVE	90028	13	148-5A185 126	5547009021	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM	04/02/2010 12:00:00 AM		Permit Finaled	10/01/2010 12:00:00 AM	ADDRESS	34.10194	-118.33601	Plan check power and enery for new electrical systen in a restaurant. Place of assembly.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63515	17041-10000-39826	4610 S VERMONT AVE	90037	9	111B197   481	5018009014	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.10	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.00126	-118.29136	Replace Outdoor existing fixtures with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63516	16041-10000-17697	4601 S CIMARRON ST	90062	8	111B189   601	5015024018	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	12/16/2016 12:00:00 AM	ADDRESS	34.0017	-118.31617	PV1 Standard 3.870 kw roof-mounted system with (18) Hyundai - S260MG modules and Enphse M215 microinverter interconnecting through a load center and the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63517	17041-10000-17675	4690 W COLORADO BLVD	90039	13	162B201    75	5593018013	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.14012	-118.27542	PC FOR POWER FOR SERVICE UPGRADE 2000A( 480/277)  WITH NEW SWITCH BOARD.ALL OTHER TO REMAIN (EXISTING).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63518	15041-10005-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 35- EMERGENCY GENERATOR RATING DOWN SIZED FROMM 500KW TO 300KW; CBs FROM GENERATOR TO EM PANELS NOW RATED 450A EACH WITH SIMILAR AIC RATINGS; EM PANELS RATED 400AT ;FEEDERS REDUCED ACCORDINGLY ; VD RECALCULATED FOR NEW FEEDERS. CHANGES ARE SHWN CLOUDED ON THE PLANS  REVISIONS TO PERMITTED SET OF PLANS.PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63519	13041-20000-02292	6330 N VARIEL AVE	91367	3	180B105    69	2149003009	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.18601	-118.59256	Plan check for energy and emergency lighting. Low-rise commercial. 6975sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63520	17041-20001-03341	15001 W CORONA DEL MAR	90272	11	123B129   651	4411024006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	34.03169	-118.52255	Changes to approved set of plans - delta revision 2 only.  Change of circuit breaker models.  (((PLANCHECK ONLY FOR POWER ONLY. SINGLE FMAILY RESIDENCE. 600AMP SERVICE.  BUILDING PERMIT # 14010-30000-01245)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63521	16041-20000-29425	7651 N GREG AVE	91352	2	186B181    14	2405008015	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.05	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	04/30/2017 12:00:00 AM	ADDRESS	34.2102	-118.35202	Plan check for a PV1 roof-mounted PV system. System size is 6.5 kWac and consists of (20) AC modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63522	13041-10000-33550	15757 W STAGG ST	91406	6	189B141   161	2206002032	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM			PC Approved	12/03/2013 12:00:00 AM	ADDRESS	34.21218	-118.47697	TITLE 24. Remove HID light fixtures and replace with new fluorescent fixtures in a commercial building.AREA 10200 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63523	12041-20000-12958	5651 N AURA AVE	91356	3	174B117   675	2153033034	(T)(Q)RZ5-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	09/24/2012 12:00:00 AM	ADDRESS	34.1741	-118.55449	New roof mounted P.V. system (5.1KWdc) with micro-inverters.Note: Some P.V. devices permit issued under 12041-20000-09124	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63524	17041-10001-39467	127 S SAN VICENTE BLVD 7TH FLR	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.07457	-118.37864	"PC FOR CHANGES TO APPROVED SET. ALL CHANGES MARKED UNDER BULLETIN  ""C"".SCOPE INCLUDES REVISIONS TO T-24 FORMS TO REFLECT NEW FIXTURES AND REARRANGMENT OF EXISTING FIXTURES. ADDITIONAL CIRCUITS FOR HAND DRAYER, MED GAS, COMPRESOR."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63525	17041-10001-44404	811 S CURSON AVE	90036	4	132B177   243	5089014033	R2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2017 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	34.06036	-118.35598	Supplemental for PV expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63526	14041-20001-11722	3205 N WASHINGTON BLVD	90292	11	108B149  1325	4229005044	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	33.9898	-118.4487	07-21-2015 Change to approve set of plan and change to an Engineer. Changes include upgrade service from 600A to 800A Service(New switch gear), changes to the load and lighting system. a complete redesign has been submitted. this application shall contain the permit for remaining items. [[[[[T.I AND ADDITION TO EXISTING SPAE. CHANGE OF USE TO NEW RESTAURANT. PC FOR PLACE OF ASSEMBLY. RELOCATED 400A SERVICE. ENTIRE NEW ELECTRICAL SYSTEM. PC FOR POWER AND ENERGY.]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63527	15041-20000-35224	15559 W HARVEST ST	91344	12	213B145   127	2662001009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.27831	-118.47161	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5KWac. (23)MODULES-KYOCERA#KU2656ZPA(1) INVERTER-ABB#PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63528	18041-10000-22156	10250 W SANTA MONICA BLVD # 1885	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM			PC Info Complete	06/28/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for T24 only, TI on existing tennat space # 1885 (Gorjana) at Century City Mall. Total area: 706 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63529	19041-20002-05375	4947 W LOS FELIZ BLVD	90027	4	150B197   119	5588009004	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.11031	-118.29732	06-25-2019 Changes to an approved set of plan, changes include remove Performace Meter and change AIC rating to of equipment to 22KAIC and additional 2 circuits. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63530	16041-20000-07575	1581 1/2 E 21ST ST	90011	9	118-5A213 156	5118002026	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Expired	04/20/2018 12:00:00 AM	ADDRESS	34.01844	-118.24496	Plan check for a PV1 roof-mounted PV system. System size is 1.3 kWac and consists of (6) modules and (6) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63531	12041-10000-05998	6215 N WOODLAKE AVE	91367	3	177B093   283	2035022035	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			Reviewed by Supervisor	04/06/2012 12:00:00 AM	ADDRESS	34.18333	-118.63174	New roof-mounted 6.125KW Enphase M215 Microinverter Photovoltaic system for an existing single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63532	12041-10000-25364	20600 W VENTURA BLVD SOUTH BLDG	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	PC FOR DELTA 3 REVISIONS. ALL CHANGES HAVE BEEN CLOUDED. ORIGINAL PERMIT UNDER APPLICATION #11041-10000-23452	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63533	10041-20000-25106	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	04/02/2013 12:00:00 AM	ADDRESS	34.10137	-118.34182	Plan check for Roosevelt Hotel Cabana power and panels upgrade supplying from existing 5000A service.All loads in unit panels are existing to remain.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63534	14041-20000-05750	1168 S HIGHLAND AVE	90019	10	132B181  1235	5084023016	R2-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.05386	-118.3411	PLAN CHECK TO VERIFY LOAD CALCULATION. THIS IS A PLAN CHECK ONLY APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63535	12041-10000-25399	3584 S FIGUEROA ST SUITE 5	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	TI IN COMMERCIAL SPACE CHANGED TO PIZZA  SHOPFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63536	19041-20001-04321	6323 N EUCALYPTUS CT	91316	5	177B125  1014	2123022053	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.1845	-118.52623	EXPEDITE PER CUSTOMER REQUESTPV1 ROOFTOP MOUNTED 11.7 kw DC / 10.483 kw AC PV SYSTEM WITH (39) MODULES , (2) AC INVERTER, (39) POWER OPTIMIZER (P320).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63537	15041-10000-41224	11212 S CONTINENTAL CITY DR	90045	11	087B173    97	4129037911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	33.93252	-118.37629	TEMPORARY CRUSHER USED AT LAX, APPLICANT TO APPLY FOR SPECIAL INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63538	18041-20000-01852	333 S GRAND AVE 1st Floor	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Title 24 only. Project site is the ground floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,724 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63539	19041-10000-47748	14006 W RIVERSIDE DR #24	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	03/11/2021 12:00:00 AM	ADDRESS	34.15713	-118.43792	Energy Plan check only, area of scope (3628)SF. Scope of work includes new lighting, panels and receptacles to an existing space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63540	13041-20000-19249	21700 W OXNARD ST SUITE 1950	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	34.17901	-118.60179	T24 FOR EXISTING OFFICE SPACE IN A HIGHRISE. SCOPE OF WORK ON SUITE 1950. TOTAL SQRFT 8749.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63541	18041-10001-15680	3440 N OAK GLEN DR	90068	4	159B177   383	2425024012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2018 12:00:00 AM			PC Approved	06/15/2018 12:00:00 AM	ADDRESS	34.13167	-118.35439	PC TO APPROVED SET TO REFLECT CHANGES TO ROOF LAYOUT OF MODULES. THIS IS PLAN CHECK ONLY. PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON SFD. SCOPE INCLUDES  22AC MODULES (SPR-X22-360-AC)SYSTEM SIZE 7.04KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63542	14041-10000-05213	10 CHESTER PL	0		TEMP000000635	5124029002							Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM			PC Approved	04/24/2014 12:00:00 AM				PLANCHECK FOR OUTDOOR LIGHTING . COURTYARD OF THE MT SAINT MARYS COLLEGE. 24000 ILLUMINATED HARDSCAPE, EXIT SIGNS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63543	16041-10000-32802	10250 W SANTA MONICA BLVD # 2790-#9280	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Petros restaurant and Kafe Bougatsa"" Ste. 2790 and 9280.  Install new transformer,  panels and circuits, total effected area: 4,982 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63544	15041-10000-33500	1294 W SUNSET BLVD	90026	1	138A211   272	5405022021	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1976.00	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Approved	11/03/2015 12:00:00 AM	ADDRESS	34.07117	-118.2508	ENERGY PLAN CHECK TO A CHANGE OF USE FROM  CONVERTING  (2) OFFICE  TENANT SPACE INTO (1) RETAIL TENANT COFFEESHOP.  SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT AND LIGHTING. TOTAL AREA IS 1177-SQ FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63545	15041-20000-40753	6909 W MELROSE AVE	90038	5	141B181   572	5525007008	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.08357	-118.34195	T-24, PC FOR ENERGY. TI TO EXISTING COMMERCIAL BUILDING (AMMO RESTUARANT). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA IS 911 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63546	19041-10000-43880	1000 W OLYMPIC BLVD THEATER 5	90015	9	127-5A205 520	5138007084	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.04578	-118.26734	FULL PLAN CHECK FOR TENANT IMPROVEMENT. SCOPE INCLUDES NEW 30KVA TRANSFORMER AND MULTIPLE NEW PANELS FOR POWER AND LIGHTING LOADS. NEW LOADS ARE CONNECTED TO EXISTING SERVICE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63547	15041-10000-06163	1460 E 25TH ST	90011	9	117A211    53	5118010006	(Q)M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.01632	-118.2478	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING CIRCUITS AND PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 9840	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63548	16041-20000-12830	10101 W WILSHIRE BLVD Admin Off.	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.06725	-118.41704	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,655 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63549	12041-20000-12527	4640 W HOLLYWOOD BLVD	90027	13	147B197   457	5542014007	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM			PC Approved	05/31/2012 12:00:00 AM	ADDRESS	34.10006	-118.29052	T24 and emergency lighting plan check for remodeled business office.  New lighting, branch circuits, and panels.  Less than 400 amperes of load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63550	15041-10000-10382	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	11/22/2022 12:00:00 AM	ADDRESS	34.07125	-118.35662	Energy plan check for a retail  T.I , Scope  include a new 400-Amp IFS swtichboard and total  in/outdoor area is 5691-SQ feet. (Tailored  method)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63551	18041-20002-03479	2735 N LA CUESTA DR	90046	4	156B177   679	5570002001	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM			PC Approved	07/11/2018 12:00:00 AM	ADDRESS	34.12104	-118.35657	Revisions to approved set of plans.  Slight relocations of equipment mounted on wall adjacent to driveway. $0 plan check fee per State Senate Bill SB 1222. (((Plan check for a PV1 roof-mounted PV system with battery storage. System size is 10.4 kWac and consists of (2) inverters, (35) modules, (2) load center, and (2) PowerWalls.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63552	16041-10002-13169	333 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   594	2424044021	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.13838	-118.35964	TITLE 24 FOR EXISTING HOTEL (TI INCLUDES :INTERIOR REMODEL OF ( E ) 21- STORY HOTEL  . ( 457 GUEST ROOMS )). SCOPE OF WORK INCLUDES CHANGING GUEST ROOM LIGHTING AND LIGHTING IN CORRIDORS IN FLOORS 1-3. NOTE: EMERGENCY LIGHTING TO REMAIN IN PLACETOTAL SQ FT. 7850TITLE 24 UNDER APPLICATION 16041-10001-13169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63553	15041-10001-24057	1500 W PACIFIC COAST HWY Bldg C	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION OF 13 DEVICES FOR FUTURE ADA REQUIREMENT.  (((NEW FA SYSTEM FOR A New 3-story, 5 unit apartment with garage, Typev VA construction. 18 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63554	18041-10000-08251	6633 N TOPANGA CANYON BLVD	91303	3	180B101   368	2139023027	(WC)TOPANGA-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.19037	-118.60613	Alterations for at a Chase bank- replacing outdoor and indoor luminaires with LED type using existing branch circuitstotal affected area 45069 sq.ft. PLAN CHECK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63555	12041-10000-16647	13488 W MAXELLA AVE	90292	11	105B153   739	4212004032	[T][Q]RAS4-1, [T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	New restaurant, first time tenant.  Full Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63556	11041-10000-20646	1002-1036 S DOREEN PL BLDG 5	90291	11	111B145   665	4243003037	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.00041	-118.46072	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63557	15041-10000-26260	7175 W WILLOUGHBY AVE	90046	5	144B181   752	5531016007	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.0872	-118.34594	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 7500.PARTIAL PERMIT FEES PAID UNDER APPLICATION NUMBER 15041-30000-24525.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63558	16041-10000-32754	5201 N LAUREL CANYON BLVD	91607	2	171B165  1234	2347018012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.16518	-118.39681	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING BANK. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3731 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63559	17041-10000-05705	5835-5837 1/2 W 88TH ST BLDG 5	90045	11	096B169   870	4125009001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Issued	04/18/2017 12:00:00 AM	ADDRESS	33.95713	-118.38441	PC FOR POWER ONLY FOR A NEW 600A 120/208 1 PHASE 3 WIRE SERVICE/DISTRIBUTION BOARD, AND NEW SUBPANELS. SERVICE IS FOR AN EXISTING 12 UNIT TENANT SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63560	16041-10000-45788	802 S FRIES AVE	90744	15	024B205    34	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	33.76172	-118.26356	NOTE: NOTE FEE ARE $0 DUE TO SENATE BILL 1222. PV2 ROOF MOUNTED SOLAR SYSTEM IN A COMMERCIAL BUILDING IN THE PORT LA. TOTAL OF 2720 MODULES AND 10 INVERTER (83KW EACH ONE). 830 KVW SOLAR SYSTEM IS TYING INTO A 1200A 4160V SWITCHBOARD AND UTILITY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63561	16041-20000-27978	15250 W VENTURA BLVD Suite 524	91403	4	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.15351	-118.46549	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,087 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63562	15041-20000-13579	5603 N AMORITA PL	91367	3	174B109   356	2151021040	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.17331	-118.58204	Plan check for a ground-mounted PV system. System size is 12.5 kWac and consists of (1) load center, (48) modules, and (48) micro-inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63563	16041-20001-16440	5808 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.09782	-118.31646	(12/16/2016)CHANGES TO AN APPROVED SET OF PLANS TO REFLCT FIELD CONDITIONS, CHANGES NOTED UNDER DELTA 20.THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63564	13041-20000-02054	7920 N BELLAIRE AVE	91605	2	189B161   521	2305013023	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2013 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Expired	02/19/2015 12:00:00 AM	ADDRESS	34.21464	-118.41222	New 7.35kw, rooftop mounted PV system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63565	15041-10000-05356	1748 W JEFFERSON BLVD	90018	8	120B193   738	5041004022	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.02541	-118.30748	TI TO AN EXISTING COMMERCIAL BUILDING (FOOD 4 LESS).  ADDING NEW LIGHTING AND CONTROLS TO WALKIN COOLER.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 950.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63566	19041-20000-41843	7737 N SEDAN AVE	91304	12	189B097  1026	2014035011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.21127	-118.6298	PV1. INSTALL 13.5 KW DC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63567	18041-10000-15957	1601 S SANTA FE AVE	90021	14	121-5A217 387	5167010901	M3-1-S-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.02515	-118.23011	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63568	14041-20000-10690	3415 S SEPULVEDA BLVD	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.02055	-118.42347	PLANCHECK FOR T24 ENERGY. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD <400 AMPS. OFFICE. 7TH FLOOR.  1337 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63569	12041-10000-05139	642 W 34TH ST 1ST FL	90089	8	120A201    84	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	PIN	34.02144011	-118.28222717	"ALTERATIONS IN A STARBUCK COFFEE SHOP IN (BURNKRANT RESIDENCE HALL)  PLAN CHK IS FOR TITLE 24    (Permit for new circuits and panels are under ""Inspection"", load is less than 400A.)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63570	19041-10000-18468	888 S DEVON AVE	90024	5	135B157    94	4359017016	[Q]R5-3	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Apartment			06/18/2019 12:00:00 AM	11/06/2023 12:00:00 AM		Issued	11/06/2023 12:00:00 AM	ADDRESS	34.06793	-118.42736	Full PC for power and energy. Scope of work includes a new 1600 A service, new equipment and new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63571	10041-10000-17752	3627 S DUNN DR	90034	10	120B165   513	4313007006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2699.01	Electrical	Electrical	Commercial			09/08/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	11/16/2010 12:00:00 AM	ADDRESS	34.02648	-118.40244	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63572	16041-10000-36940	2783 W FRANCIS AVE	90005	1	132A201    90	5077021014	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			10/18/2016 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	08/30/2022 12:00:00 AM	ADDRESS	34.05694	-118.28632	FULL PC FOR POWER AND ENERGY FOR A NEW 6 STORY 50 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW 1600A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW SUBPANELS, NEW RECEPTACLES, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 43605 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63573	15041-10000-28056	5419 W HOLLYWOOD BLVD A-E	90027	13	148-5A193 343	5544007900	C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.10194	-118.30783	ALTERATIONS IN A T-MOBILE RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63574	19041-10000-33862	5240 N NOBLE AVE	91411	4	172-5A147 211	2250019008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.16606	-118.46161	(ePlan) PV1. PLAN CHECK FOR ROOF MOUNTED PV SYSTEM WITH BATTERY BACKUP. SYSTEM  CONSISTING OF 14 MODULES (Q-CELL 315), 14 OPTIMIZERS (SE P320), 1 INVERTERS(SE3800H-US) AND 1 BATTERY (LG CHEM) CONNECTED TO AN EXISTING 200A SERVICE. SYSTEM SIZE IS 4.48 KWdc AND 3.8KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63575	16041-20002-44993	5400 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM			PC Approved	11/07/2018 12:00:00 AM	ADDRESS	34.06201	-118.34659	11-07-2018 Changes to an approved set of plan, Changes include update as build from Cutler Hamer to Square D short circuit current series rating. All changes has been clouded as delta 5 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63576	10041-10000-15649	5756-5760 W 3RD ST	90036	4	135B181   191	5508002028	C2-1	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/11/2010 12:00:00 AM		Permit Finaled	10/12/2010 12:00:00 AM	ADDRESS	34.06874	-118.34548	T.I. to existing building.  Install general/emergency lighting in restroom and waiting area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63577	16041-10000-09823	12685 W SUNRISE PL	90094	11	102B161  1275	4211037031	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.9766	-118.41428	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.08KWac, WITH AN AC MODULE SUPERVISOR. (8)AC MODULES-SPR-X20-250-BLK-B-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63578	15041-20000-33506	9420 N LURLINE AVE # F	91311	12	198B109   207	2748041035	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.24121	-118.58402	TI for processing area of for dental implans. NO Exam room involved. PC for Energy only, total area: 1448 sq. ft. Installing new lighting fixtures and switches to (E) electrical equipment.**Total area after verification: 1,918 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63579	13041-10000-19742	7051 N PETIT AVE	91406	6	183B137   153	2225012021	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	08/28/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.19894	-118.49698	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE STORY SINGLE FAMILY DWELLING. NON STANDARD PLAN. SYSTEM SIZE IS 5.635 KW. USING 23 MODULES ON 2 STRINGS, AND 1 INVERTER. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTER: POWER-ONE # AURORA PVI-5000-OUTD-US-Z]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63580	17041-20005-16993												Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM				"02/23/2018 changes to approved set of plans to cleanroom only - removal and relocation of loads in this area only. 12/13/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes include the removal of ""HDS2"" and the relocation of a transformer and a fused disconnect switch.11/30/17changes to an appropved set of plans.  changes noted delta 1.  changes include alteration to existing lighting system, revised energy calculations.  plan check for energy indoor only.  (((PC for power and energy for TI for electronic manufacturing facility in second floor of building. PC includes check for new 3000 A 277/480 service, new electronic manufacturing equipment, spray booth, outdoor compressor and power supply units for equipment. Total affected area is 15369 sqft.Bulding # 17016 20000 05741)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63581	10041-10000-10084	530 W 27TH ST	90007	9	121-5A203 130	5123018019	(T)(Q) C2-2, D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	34.0269	-118.27607	5-STORY, TYPE III-A, 161-UNIT STUDENT HOUSING OVER TYPE 1-A, 2ND FLOOR GARAGE OVER TYPE 1-A, 1ST FLOOR COMMERCIAL LEASE SPACE / PKG, OVER TYPE 1-A BASEMENT PKG GARAGE (total 7-story building with one level basement parking per granted modification, see comments).((((( install new  voice evac fire alarm systems)))))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63582	11041-10000-24388	18607 W VENTURA BLVD #100	91356	3	174B121   559	2160006037	C2-1L, R3-1	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			11/15/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.17006	-118.53874	T.I. for an existing restaurant in suite #100.  PLAN CHECK for Energy, with Emergency lighting.  Permit for new circuits & lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63583	15041-20000-14393	1024 S BURNSIDE AVE	90019	4	132B181   778	5085009008	R1-1-O	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2015 12:00:00 AM	05/12/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.05647	-118.35158	Plan check for PV roof monted 3.8kWac system with 10 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63584	17041-10000-40557	3918 W BEVERLY BLVD	90004	13	138B197   370	5518026001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.07613	-118.29368	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPESPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63585	18041-10000-23291	11717 W SANTA MONICA BLVD	90025	11	126B149   293	4262003004	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.04366	-118.45682	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63586	11041-10000-18050	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	PIN	33.93847109	-118.41935625	NEW FIRE ALARM FOR AIRPLANE HANGAR ADDITION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63587	14041-20000-04925	1250 N BEL-AIR ROAD	90077	5	147A153   463	4370029011	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Expired	05/23/2017 12:00:00 AM	ADDRESS	34.09618	-118.44375	"""0$ permit fees due to senate bill 1222""pv1 single family dwelling. total system size 17kw ac using transformerless inverters nonstandard plan. total of 78 modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63588	15041-20000-20845	6501 W OLYMPIC PL	90035	5	132B173   458	5087007009	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.05819	-118.37215	Plan check for PV roof mounted system. System size: 6.0kW with 24 modules and 1 inveter(6.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63589	18041-10000-30421	970 W 190TH ST STE 660	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/13/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.85812	-118.29302	PC FOR OFFICE TI IN A HIGH RISE. SCOPE INCLUDES NEW LIGHTS CIRCUITS AND RECEPTACLES.  TOTAL AFFECTED AREA 1668 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63590	15041-30000-43724	10900 W WILSHIRE BLVD Suite 620	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.05848	-118.44419	Title 24 plan check only.  Total area = 4,295 sq. ft.     T.I. to existing commercial highrise office space.  New HVAC, lighting and receptacles.Building permit #15016-20000-27886	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63591	12041-10000-23249	140 S RENO ST 1-109	90057	13	136-5A201  20	5155004025	R4-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Info Complete	09/28/2012 12:00:00 AM	ADDRESS	34.07028	-118.28178	title 24 , 3 story bldg. lobby lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63592	17041-10000-23522	1245 W WILSHIRE BLVD STE 390	90017	1	132A207   288	5143017041	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM			PC Info Complete	08/04/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	Plan check for power and Title 24.  First time T.I. to existing medical office including exam rooms, treatment rooms, and blood draw rooms.  One new subpanel with lighting and receptacles.  Lighting area = 5,738 sq. ft.       Building permit #17016-10000-18983	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63593	14041-10000-34308	1400 E OLYMPIC BLVD #216	90021	14	123A213   180	5130002043	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.03107	-118.2433	Plan check for Title 24 only. Scope of work is to remove HID light fixtures and replace with new LED fixtures. Total lighting area = 6420 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63594	12041-10000-19659	8407 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	05/08/2013 12:00:00 AM	ADDRESS	34.22266	-118.62737	New 1200 Amp switchboard with new subpanels, lighting, and loads for an existing 2-story office building.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63595	10041-20000-09930	11550 N INDIAN HILLS ROAD	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1066.06	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Closed	09/20/2011 12:00:00 AM	ADDRESS	34.27998	-118.45874	PLAN CHECK FOR INDOOR ATTENDANT BOOTH AND OUTDOOR LIGHTING. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63596	15041-20001-27287	16032 W VALLEY VISTA BLVD	91436	5	168B141   860	2283015007	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM			PC Approved	09/04/2015 12:00:00 AM	ADDRESS	34.15302	-118.4827	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 23.1 kWac and consists of (3) inverters, (73) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63597	16041-10000-10819	8500 W BEVERLY BLVD BASEMENT	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	T-24,  NEW TEMPORARY OFFICE ON PORTION OF GARAGE FOR MALL REBRANDING PROJECTS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 6865.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63598	17041-20000-30920	11140 N BALBOA BLVD	91344	12	210B133   327	2682021032	C4-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.27319	-118.50196	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63599	19041-20000-32300	8424 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63600	16041-20001-30566	12196 W VENTURA BLVD	91604	2	162B165   214	2369004039	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.14305	-118.39841	Retail TI.  Plan check for energy - 1600 Sq Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63601	19041-20000-03957	7551 W SUNSET BLVD	90046	4	147B177   981	5550009023	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.09821	-118.35418	Plan check for emergency egress lighting and exit signs. Dog E Den. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63602	12041-20000-29269	1006 N CHANTILLY ROAD	90077	5	144B149   264	4369036011	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2012 12:00:00 AM			PC Info Complete	03/26/2013 12:00:00 AM	ADDRESS	34.08957	-118.45467	New single family residence with a 600 amp service.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63603	13041-10000-34338	510 E 12TH ST	90015	14	124-5A209 220	5145026035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.03471	-118.25509	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63604	12041-10000-17671	150 W JEFFERSON BLVD	90007	9	118-5A203 115	5122031001	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	ADDRESS	34.01918	-118.27417	Change of use from Warehouse to Church.  Full Plan Check Required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63605	10041-30000-12597	161 S LA BREA AVE	90036	5	138B181  1136	5513019005	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/01/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	10/19/2010 12:00:00 AM	ADDRESS	34.07185	-118.34424	TI in an existing commercial space. Existing 400 amp service core and shell. Complete Electrical Plan Check may be required subject to field inspection. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63606	14041-20001-03262	770 N RIDGEWOOD PL	90038	13	141B189   102	5535004027	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.08549	-118.3145	(((Expedite fees)))PV1 TRANFORMERLESS SYSTEM. USING POWER OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63607	16041-10000-31383	700 W 7TH ST G260	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	TI FOR RETAIL WITH MEDICAL ROOMS. OPTOMETRY. PC FOR POWER AND ENERGY IN ACCORDANCE WITH 517.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63608	18041-10000-22823	3342 S LA CIENEGA BLVD	90016	10	120B173   249	5048016026	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.027	-118.37186	This is a one story existing restaurant , T,I  from restaurant to a restaurant.  Scope of work is TITLE 24 and emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63609	18041-10001-44774	19069 W BRAEMORE ROAD	91326	12	216B121    41	2820012011	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM			PC Approved	12/12/2018 12:00:00 AM	ADDRESS	34.29249	-118.54951	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63610	11041-10000-19402	15701 W PACIFIC COAST HWY	90272	11	123B125   171	4413025902	OS-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM			PC Approved	03/28/2012 12:00:00 AM	ADDRESS	34.03539	-118.53443	T-24 lighting plan check for NEW RESTROOM BLDG IN CITY PARK.  <<<PERMIT WAS ISSUED  11041-10001-19402>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63611	15041-20000-02518	18729 W VENTURA BLVD	91356	3	174B121   512	2160002050	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.17122	-118.54161	T.I. to existing building.  Install general lighting.  Plan check for energy only.Note: permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63612	11041-10001-21232	1057 N VINE ST	90038	13	144B185   814	5533017010	C2-1D-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM			Reviewed by Supervisor	10/15/2012 12:00:00 AM	ADDRESS	34.09007	-118.32679	(((((((((((((((((((((((((9-6-12   Changes made to previously approved set , change in fixture type and title 24.))))))))))))))))Ground up renovation for an existing hotel.  New service, all new circuits and panels and equipment, including PV system.  Plan check for POWER and Energy.  Variance will be filed to seperate fire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63613	14041-20004-21443	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			01/14/2016 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.19603	-118.45077	Change to approved set of plans. Changes include Available Fault Current from 70kAIC to 41kAIC per LADWP, Service equipment  (Series ratting 65kAIC), panel board (Series Ratting 65kAIC). {{{{{{{{Plan check for power and energy (2008 Energy Code). New 49-unit apartment building, 3-stories. Fee calcs provided by applicant - verify. Fire alarm variance filed.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63614	16041-20001-08962	19338 W LEMAY ST	91335	3	180B117   406	2131006002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.19127	-118.55493	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. New 3kW ungrounded system is an addition to an existing 5kW system on the roof. Interconnecting with a 200A MSP, derating the main to 175A. (9) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63615	16041-10000-19099	1611 S WESTERN AVE	90006	10	126B193   319	5073012031	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	34.04297	-118.30926	TI of an existing Carl's Jr restaurant. Relocate Main Pullbox and replace all panels, 800A (E) service. PC for Power and Energy. Total area 4,485 sq.ft (indoor+outdoor)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63616	18041-10000-39128	2049 S CENTURY PARK EAST #1900S	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	TENANT IMPROVEMENT IN EXISTING OFFICE SPACE ON THE 19TH FLOOR. 13,576 SQR FT OF T-24 ENERGY ONLY.BLDG PERMIT: 18016-10000-28483	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63617	17041-10000-04764	2424 E WHITTIER BLVD	90023	14	123A221    12	5189009049	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.03382	-118.2148	CHANGING OUT OLD FIXTURES FOR MORE ENERGY EFFICIENT. PC FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA IS 34775 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63618	14041-10000-17120	954 N SOMERA ROAD	90077	5	144B149   348	4369034014	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Expired	09/27/2017 12:00:00 AM	ADDRESS	34.08713	-118.45642	PC FOR POWER AND ENERGY. SINGLE FAMILY, 2-STORY HOUSE. TOTAL AREA  14290 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63619	15041-20000-23869	8652 N CASABA AVE	91306	3	195B113   576	2781011011	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.22792	-118.57617	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (18) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63620	13041-10001-36174	113 S ROBERTSON BLVD	90048	5	138B169   406	4334001027	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.0748	-118.3839	((((4/24/2014-changes made to approved set of plans - change some light fixtures, energy calculation to be verified. cHANGES on plans include ckt 32 has lock-on device. Inspector to verify ETL listing of pendant PL. Plan check only.)))))permit to be pulled at EPC counter only. PC for energy only. 2 story. emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63621	17041-10001-38270	723 N JUNE ST	90038	4	141B185   453	5524008009	R1R3-RG	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM			PC Approved	06/22/2018 12:00:00 AM	ADDRESS	34.08413	-118.3343	PC FOR CHANGES TO APPROVED SET PER APPLICANT REQUEST. SCOPE INCLUDES CHANGES TO THE PLACARD TO REFLECT ALL LOAD CENTERS AND DICONNECTS. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63622	17041-10000-19427	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	33.89279	-118.28725	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63623	17041-10000-34094	3043 S CAVENDISH DR	90064	5	123B161   123	4316011014	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM			Verifications in Progress	10/17/2017 12:00:00 AM	ADDRESS	34.03657	-118.406	PC FOR ROOF MOUNTED PV ON SFD WITH POWERWALL BATTERY.TOTAL SYSTEM SIZE IS 3.0KWac/ 4.0 KWDC(10)MODULES WITH OPTIMIZERS (1)INVERTER-(1)200A SUBPANEL(1)TESLA AC POWERWALL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63624	17041-10000-19353	5028 S DENKER AVE	90062	8	111B193  1269	5016034011	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2323.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	33.99733	-118.30441	PC FOR ROOF MOUNTED PV SYSTEM ON SLD. SYSTEM SIZE 5.0KWACWITH 17 MODULES WITH 17 OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63625	11041-20001-13158	11600 W WILSHIRE BLVD 2&5 FLR.	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM			PC Approved	07/06/2011 12:00:00 AM	ADDRESS	34.05034	-118.45947	Corridor upgrade. EPC is for T24. (Permit was pulled # 11041-20001-13158)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63626	16041-30000-38103	754 S WALL ST	90014	14	126A211   123	5145005008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.04061	-118.24966	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63627	18041-20001-41148	17347 W SAN FERNANDO MISSION BLVD	91344	12	210B129   322	2711010015	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.27227	-118.51262	Expedite fee. PV1.  Install 23.485 kW roof mounted grid tied PV system.  (77) modules with 10.0 and 11.4 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63628	13041-10000-34622	15300 W VICTORY BLVD	91411	6	180B145   800	2242009022	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	PIN	34.18637398	-118.4665531	Remove HID light fixtures and replace with new fluorescent fixtures in auto repair shop.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63629	19041-10001-19127	10250 W SANTA MONICA BLVD 1970	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM			PC Approved	08/12/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to an approved set of plans, changes include the revision of note 5 and relocation of switch bank. Note all changes under delta-1 and clouded areas only. ____________________________________________T-24, PC for energy only. T.I. to existing retail store. Scope includes new lights and receptacles. Total affected area is 5227 Sq. Ft. B#19016-10000-15041	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63630	17041-20000-23238	9430 N TOPANGA CANYON BLVD 1st & 2nd-fl	91311	12	198B101   335	2746013041	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.24159	-118.60598	ti to an existing commercial building two story.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 4415	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63631	14041-10000-31577	380 WORLD WAY Space T90	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check only for T.I of  airport concession space #T90(iStore). 702 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63632	16041-10000-05540	3796 S DUBLIN AVE	90008	10	117B189   732	5034013020	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	PIN	34.01733633	-118.32208105	PV1, INSTALL 3445 kW DC  ROOF-MOUNTED  SOLAR ARRAY ON A SINGLE FAMILY HOME(13) MODULES: CANADIAN SOLAR CS6P-265P(1) INVERTER: SOLAREDGE SE 3000A-US 240VP300 is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63633	14041-10001-14951	5301 N WINNETKA AVE	91364	3	171B113   166	2166006001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			Reviewed by Supervisor	06/18/2014 12:00:00 AM	ADDRESS	34.16609	-118.57071	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS NON STANDARD PLAN. SYSTEM SIZE: 9 KW DC.(36) ET SOLAR MODULES(2) POWER ONE PVI 3.8 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63634	14041-10000-05347	901 E E ST	90744	15	030B209   720	7424014095	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	33.77631	-118.25153	New Methane mitigation system for a single story commercial Bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63635	18041-20001-25388	1308 1/2 N MALTMAN AVE	90026	13	142-5A203 507	5427022041	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	34.08647	-118.27882	09/28/2018 Changes to an approved set of plans. Roof layout has been revised.*****Previous Work Description*****PV1.  Install 5.49 kW roof mounted grid tied PV system.  (18) modules with 5 kW rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63636	14041-20000-28034	21555 W MULHOLLAND DR	91364	3	165A105    75	2190002008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.14722	-118.60053	PV1Microinverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5.76kW. (24) Enphase M250 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63637	12041-10000-27106	15330 W RAYMER ST	91406	6	189B145   364	2222001009	M2-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00, 1275.20	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	06/24/2013 12:00:00 AM	ADDRESS	34.21555	-118.47046	PV2 COMMERCIAL SOLAR INSTALLATION. 742KW SYSTEM. APPLICANT ASKED TO BE CALLED WHEN CORRECTIONS ARE ISSUED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63638	14041-10000-20422	9603 N VAN NUYS BLVD	91402	6	201B149   642	2650021***	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.24455	-118.45043	PV2, ROOF-MOUNTED SOLAR ARRAY ON A COMERCIAL BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL.(12) KYOCERA KD255GX-LFB3(1) POWER-ONE INVERTER: AURORA PVI-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63639	11041-10000-02470	1139 S GLENDON AVE	90024	5	132B153   241	4363022010	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/08/2011 12:00:00 AM			PC Info Complete	03/09/2011 12:00:00 AM	ADDRESS	34.06007	-118.44389	INTERIOR ALTERATIONS OF EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24 AND 3 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63640	11041-10000-12377	3785 W WILSHIRE BLVD # 107E	90010	10	132B193    30	5503030025	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.06187	-118.30858	CHANGE OF USE FROM RETAIL TO COFFEE SHOP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63641	13041-20000-31095	1859 W ADAMS BLVD	90018	8	123B193   594	5058020014	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.03286	-118.30497	PC FOR T24 ENERGY ONLY. TOTAL AREA 1500 SQ FT PLUS OUTDOOR LIGHTING. RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63642	14041-20000-31057	10100 W SANTA MONICA BLVD suite 1070	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM			Corrections Issued	11/07/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for energy only. TI for an existing office on the 10th floor of an existing high rise office building.  New receptacles and lighting (incl. emergency). 1,631sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63643	13041-20000-01551	445 S FIGUEROA ST 25th Floor	90071	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.00, 2077.10	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/19/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for energy and emergency lighting. 25th floor. 1983sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63644	14041-20001-09669	13610 W STRATHERN ST	91402	6	189B157   435	2214026021	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM			PC Approved	04/03/2015 12:00:00 AM	ADDRESS	34.21519	-118.42917	Changes to approved set.  Changing MC cable to Romex.*****Previous Work Description*****NEW CONSTRUCTION, APARTEMNT BUILDING (34 UNITS) high rise residential. pc for power and energy.fire alarm variance has been filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63645	13041-10000-25796	3017 S CRENSHAW BLVD	90016	10	120B185   530	5050031038	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Expired	10/13/2015 12:00:00 AM	ADDRESS	34.02707	-118.33531	This is a new fire alarm for a church one story. one panel and 39 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63646	18041-20001-12148	10580 W STALLION RANCH ROAD	91040	7	204B177   253	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.25709	-118.36008	expeditepv1install roof mountrd pv system sized 18.4kw AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63647	13041-20002-34372	6500 W SELMA AVE	90028	13	148-5A187 328	5547017001	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM			PC Approved	07/23/2015 12:00:00 AM	ADDRESS	34.09966	-118.33121	07/23/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 3. Changes to the roof power and lighting. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****[[[[10/22/14  CHANGES TO APPROVED SET. DELTA 2 CHANGES ONLY. CHANGES TO INDOOR LIGHTING PLUS INCLUSION OF MEZZANINE IN T24.]]]]POWER AND ENERGY FOR LOWRISE HOTEL WITH 2000A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63648	18041-10000-33947	19780 S PACIFIC GATEWAY DR #B-200	90502	15	057B197    48	7351034069	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.85141	-118.29512	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63649	14041-20000-28129	4057 W SEA VIEW AVE	90065	1	150A221    64	5464008004	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.10668	-118.21543	PV1.  Install 5.67 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63650	17041-10001-24842	835 W JEFFERSON BLVD 7A & 7B	90007	9	121-5A201 201	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	CHANGES TO APPROVED SET OF PLANS. UPDATED EMERGENCY LIGHTING TO BE INSTALLED THRU BYPASS RELAY FROM EMERGENCY PANEL. EACH FIXTURE NOW 2 CIRCUIT TYPE EXCLUDING EXIT SIGN WHICH STILL HAS INTERNAL BATTERY. NO OTHER CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63651	18041-10000-46730	1571 S WESTWOOD BLVD	90024	5	129B153   123	4324026027	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Re-Activate Permit	05/21/2019 12:00:00 AM	ADDRESS	34.05284	-118.43989	Design build: Energy plan check for a commercial T.I, Scope includes new lighting and equipment with a total area of 1,100 SQ FT.Portion of the permit is paid under 18041-30000-42357	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63652	18041-10000-48852	800 W 6TH ST SUITE 950	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Issued	01/15/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	PLAN CHECK FOR TITLE 24 ONLY FOR - NON BEARING TENANT IMPROVEMENTS FOR 5,579 SF.  NEW ACOUSTICAL CEILING, LIGHTING, MILWORK, FLOOR AND WALL FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63653	14041-10000-23723	523 W 6TH ST #1105	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	plan check for energy only. Permit to be pulled at EPC counter only. TI (e) office space suite 1105. Changes on plan include emergency lighting clarification of UL 924 shunt relay and T24 controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63654	18041-20000-37760	13131 W SHERMAN WAY #201	91605	2	183B157    37	2327003053	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.20136	-118.41904	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to bakery/tenant improvement. Total lighting area = 1,696 sq. ft.Note: Building permit has been issued under 18016-20000-15719	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63655	19041-10000-08608	936 S OLIVE ST	90015	14	127-5A209 231	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	12/28/2021 12:00:00 AM	ADDRESS	34.04287	-118.25873	FULL PLAN CHECK FOR SEPARATE EXISTING RETAIL TENANT SPACE IN TO THREE TENANT SPACES.  CHANGE OF USE PORTION OF RETAIL SPACE TO RESTAURANT WITH OUT-DOOR PATIO COVERED DINNING. TOTAL AREA IS 4947-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63656	17041-20001-25138	6907 N BALCOM AVE	91335	3	183B129   804	2122004007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM			PC Approved	07/31/2017 12:00:00 AM	ADDRESS	34.19582	-118.52074	expeditepv1install roof mounted pv system sized 3kw interconnected with msp.  this is an addition to an existing system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63657	17041-10000-12599	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Issued	06/21/2017 12:00:00 AM	ADDRESS	34.02557	-118.3665	PC for power and energy for shell space for converter warehouse to future office building with new 3000A 277/480V service. Total affected area is 97707 sqft. Building # 17016-10000-09705	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63658	18041-10001-30292	10960 W WILSHIRE BLVD 22ND FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.058	-118.44597	SUPPLEMENTAL FOR CHANGES TO APPROVED SET, REMOVAL OF PROPOSED LIGHTS. PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63659	16041-30000-28579	2029 S CENTURY PARK EAST 10th FL-Lobby	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Issued	11/03/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in elevator lobby 10th floor in existing high-rise. Total lighting area: 340 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63660	19041-10000-19132	9669 N OSO AVE	91311	12	201B113   671	2748016028	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.24604	-118.57552	pc for 6.51kw pv system, system consists of  21 modules with microinverter, 1 combinerbox.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63661	14041-20000-17010	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	33.96577	-118.42406	fire pump ahead of main	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63662	18041-10000-29608	19601 S HAMILTON AVE	90502	15	057B197    81	7351033023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	02/03/2020 12:00:00 AM		Permit Finaled	02/14/2022 12:00:00 AM	ADDRESS	33.85319	-118.28624	PC FOR POWER AND ENERGY.  TI FOR AN OFFICE/MANUFACTURER BUILDING. SCOPE OF WORK INCLUDES INSTALLING NEW 3D PRINTERS, NEW PANELS, CIRCUITS AND LIGHTING. TOTAL LOAD > 400 AMPS. TOTAL AFFECTED AREA IS 3789 SQ. FT. . B#18016-10000-25161	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63663	19041-20001-13845	10700 N FULLBRIGHT AVE	91311	12	207B113    87	2707004019	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.26478	-118.57685	SUPPLEMENTAL FOR EXPEDITEPC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 13.02KW DC/10.08KW AC. SCOPE OF WORK INCLUDES (42) MISSION SOLAR 310W PV MODULES AND (42) ENPHASE IQ7 MICRO INVERTERS AND A IQ COMBINER 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63664	17041-20000-15179	222 E 16TH ST	90015	14	123A207    57	5133015010	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/08/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Issued	10/12/2017 12:00:00 AM	ADDRESS	34.03253	-118.26099	Tenant improvements for future move-in.  New 800A 240V 3ph-4w service and distribution.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63665	11041-20000-15319	3481 E 14TH ST	90023	14	118-5A225 357	5190036025	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/21/2011 12:00:00 AM	ADDRESS	34.01738	-118.20365	Revision to approved plans 10041-20000-20810. Install 126.54KW photovoltaic system to 1600A service. No plan check for new 75KVA xfrmr, 225A subpanel, and 200A disconnect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63666	19041-20000-03063	24073 W JENSEN DR	91304	12	193-5A089 168	2017011019	RA-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.22316	-118.65106	Plan check for PV roof mounted system, system size: 2.835KW with 9 PV Modules and 1 inverter 3.0KW  connected to 400A Panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63667	13041-20001-10887	5023 N STERN AVE	91423	4	171B153   735	2269005013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.162	-118.43468	SUPP APPLICATION FOR CHANGES TO APPROVED SET OF PLANS. CLOUDED 2 CHANGES ONLY. CHANGES ARE PHOTOVOLTAIC MODULE TYPE AND NOTATION THAT PANEL IS EXISTING TO REMAIN. PC ONLY. NO PERMIT TO BE ISSUED UNDER THIS APPLICATION.micro invereter solar single family	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63668	14041-20000-04973	5347 N HINTON AVE	91367	3	171B093   123	2044012005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Expired	04/19/2016 12:00:00 AM	ADDRESS	34.16786	-118.63771	pv1 single family dwelling. total system size 10kw ac using transformerless inverters nonstnadard plan. using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63669	18041-20000-33964	954 S CATALINA ST	90006	10	132B197  1160	5078007024	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.20	Electrical	Electrical	Apartment			09/05/2018 12:00:00 AM			Reviewed by Supervisor	10/11/2018 12:00:00 AM	ADDRESS	34.05403	-118.29462	Plan check for power and energy. Project site is a 5-story, 19-unit apartment building. Work includes a new 1,000-amp service and a total lighting area of 14,435 sq. ft.Note: Building application has been generated under 17010-10000-03028	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63670	15041-10000-15634	1130 S ABBOT KINNEY BLVD	90291	11	108B145  1164	4238003025	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	33.99144	-118.46965	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63671	17041-10000-10842	18909 W VENTURA BLVD	91356	3	174B121   450	2161001***	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.1726	-118.54518	TI, NEW LIGHTING. PC FOR T24 ENERGY ONLY. MCDONALDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63672	19041-10000-16204	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.21302	-118.45859	TI IN A TARGET STORE. FULL PLAN CHECK FOR POWER & ENERGY. NEW LIGHT FIFIXTURES, CIRCUITS. TOTAL AREA: 110,348 SQR FT.BULDING PERMIT: 19016-10000-06567	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63673	17041-10000-22801	1415 E WASHINGTON BLVD	90021	9	120A213   221	5129007019	M2-2	South Los Angeles	Southeast Los Angeles			2260.00	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Info Complete	08/07/2017 12:00:00 AM	ADDRESS	34.02296	-118.24735	PLAN CHECK FOR POWER ONLY - SCOPE INCLUDES SERVICE UPGRADE TO 1200A. PLAN CHECKER TO REQUEST ELECTRICAL ROOM INFORMATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63674	18041-20000-17751	11805 W GWYNNE LANE	90077	5	153B141   103	4378037075	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.11583	-118.47417	PV1.  Install 9.425 kW DC roof mounted grid tied PV system.  (29) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63675	11041-10000-22828	3900 E CHEVY CHASE DR Bldg #123	90039	4	159B205   748	5593002907	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.13327	-118.27281	new maintenace shop buildingPlan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63676	18041-10000-23417	7228 W BEVERLY BLVD	90036	5	138B181   445	5512023001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM			PC Approved	06/26/2018 12:00:00 AM	ADDRESS	34.07598	-118.34719	Energy plan check for an existing commercial T.I. Scope includes adding new lighitng and equipment with a total T-24 area cover 3285-SQ FT. All permit fee is paid under 18041-90000-22763.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63677	15041-10000-04590	11462 W PENROSE ST	91352	6	192B169   472	2632010014	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.22203	-118.38107	RETRO FIT EXISTING LUMINAIRE TO LED IN THE LOUNGE AREAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63678	14041-20000-11517	17600 W SUNBURST ST	91325	12	195B129    72	2768025002	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.23445	-118.51797	New roof mounted PV system with microinverters, system size is 5.2KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63679	13041-20000-00202	4820 E MENDOTA AVE	90042	1	154-5A223 245	5477024011	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2013 12:00:00 AM			Reviewed by Supervisor	01/17/2013 12:00:00 AM	ADDRESS	34.1174	-118.21126	New 5.39kw rooftop mounted PV system for an existing single family residence.  System is ungrounded/transformerless and uses SolarEdge Optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63680	11041-20000-10765	6333 W 3RD ST #020-#P20	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	11/28/2011 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	Plan check for power and energy. New panels, ckts and equipment. TI restaurant (place of assembly)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63681	19041-20000-45906	17169 W ESCALON DR	91436	5	159B133   103	2292020014	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.13369	-118.504	Plan check for PV roof mounted system, PV system size: 5.94KW with 18 PV Modules and 18 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63682	13041-20000-25612	7479 N WESTCLIFF DR	91304	12	186B089   312	2027045013	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	PIN	34.20703816	-118.64845321	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.6 KW AC USING TRANSFORMERLESS INVERTERS. 2 CENTRAL INVERTERS. 4 STRINGS/ INVERTER. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63683	16041-10000-37950	1019 S SANTA FE AVE	90021	14	123A217   235	5166011006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Info Complete	11/14/2016 12:00:00 AM	ADDRESS	34.03092	-118.23019	T-24, PC FOR ENERGY ONLY. TI TO (E) URM BUILDING CHANGE OF USE FROM MANUFACTURING TO COFFEE SHOP WITH RETAIL AREA. SCOPE INCLUDES TWO NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. TOTAL AFFECTED AREA IS 2267 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63684	10041-20000-03847	8614 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM	03/08/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.07598	-118.37831	Revision to  previously approved plan  application # 09041-20000-15656. The changed has been clouded indicating the lighting plan, power and installation of 75kva transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63685	16041-20002-26777	7172 W HAWTHORN AVE	90046	4	147B181   449	5548011061	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.09956	-118.34638	changes to an approoved set of plans.  changes include (1) 8kw inverter and reconnect to msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63686	09041-10001-16629	1248 S FIGUEROA ST	90015	9	126A205    19	5138025014	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM	08/09/2010 12:00:00 AM		Permit Finaled	03/22/2011 12:00:00 AM	ADDRESS	34.04096	-118.2674	Addition of 18 new ckts and 35000sqft  of outdoor lighting. and emergency lighting	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63687	18041-20000-21825	1101 N MAIN ST	90012	1	135A217    85	5409006040	UC(CA)	Central	Central City North	Los Angeles Historic Cultural		2060.10	Electrical	Electrical	Apartment			06/12/2018 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	12/20/2021 12:00:00 AM				New 7-story 318-unit apartment building.  4000A 480Y/277V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63688	19041-10000-52856	525 S SANTA FE AVE	90013	14	126A217   216	5164003015	M3-1-RIO  /  [T][Q]C2-2-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	05/31/2022 12:00:00 AM		Issued	05/31/2022 12:00:00 AM				(TWO NEW TOWERS) THIS PROJECT: NEW 35 STORY HIGH RISE MIXED USE BULDING. INSTALLING 4,160 V - MED VOLTAGE SERVICE, 2 @ 250HP Fire Pumps, 1,250KW Emergency Generator, 5 Elevators, Panels, Lights, Etc. Affected Area: 1,124,144 SFTBULDING PERMIT: 18010-10000-05907((((PROPOSED 35 STORY MIXED USE HIGHRISE BUILDING. 475 LIVE/WORK UNITS, OFFICE, RETAIL AND 2 LEVELS OF BASEMENT GARAGE.  11% (53 UNITS)  OF THE TOTAL UNITS (475)  WILL BE RESERVED  AS VERY LOW INCOME UNITS.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63689	18041-20000-15832	20638 W CHESTNUT CIR (#330)	91326	12	219B109   357	2761001***		North Valley			YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.29315	-118.58392	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63690	17041-10000-31118	444 S FLOWER ST 23RD FLR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	ADA RESTROOMS, PUBLIC CORRIDOR AND ELEVATOR LOBBY FINISH RENOVATION. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63691	12041-10000-26162	3060 S CRENSHAW BLVD	90018	10	120B185   804	5051029029	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM			Reviewed by Supervisor	11/09/2012 12:00:00 AM	ADDRESS	34.02579	-118.33489	"Plan check power and energy. First time tenant ""Fresh & Easy"". Core and shell electrical plan check under #11041-10000-10026."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63692	11041-10000-02731	1640 S SEPULVEDA BLVD suite#120	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.04838	-118.44468	Ti for an existing office building. (no medical equipment, not a health care facility) EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63693	14041-20001-15600	4119 N ST CLAIR AVE	91604	2	165B165  1180	2367013024	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.14539	-118.39994	CHNAGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 1.PV1Install roof-mounted solar array on SFD. System size: 3.8kW.(1) SolarEdge SE3800A-US transformerless inverter(14) ReneSola JC250M-24/Bb pv modules(14) SolarEdge P300 power optimizers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63694	11041-10002-05924	15249 W VICTORY BLVD	91411	6	180B145   596	2235001022	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM			PC Approved	11/03/2011 12:00:00 AM	ADDRESS	34.18686	-118.4657	Modification to an approved set of plans.  On the approved set of plans, there was going to be a 400 Amp breaker going to panel DP and then that panel feeding panels A and B.  The changes are that now, they will be using the existing breakers (200 Amp breakers) fro panels DP and B and panel A will get a new 100 Amp breaker.  Panel DP will no longer be feeding panels A & B and so it has been downgraded from aq 400 AMP panel to a 225 Amp panel.  <<<<<<<CHANGES TO PERMITTED SET OF PLANS- ADDED LUMINAIRES ;REVISED THE LAYOUT OF A ROOM; ADDED RECEPTACLES New Chase bank. EPC is for power & Energy.>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63695	17041-10000-13249	6701 N FALLBROOK AVE	91307	12	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.19099	-118.62361	"PC FOR POWER AND ENERGY. TENANT IMPROVEMENT OF ""BOB'S DISCOUNT FURNITURE"".  NEW CONNECTED LOAD > 400 AMP.ADDITION OF NEW (4) 400AMP PANELS AND (2) NEW 200 AMP PANELS. TOTAL AREA 33093 SQ FT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63696	17041-10000-16781	4467 N VANALDEN AVE	91356	3	165B117    26	2178026014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.15231	-118.55645	PC FOR ROOF MOUNTED PV USING AC MODULES.includes 37 AC modules 360wtotal system size 13.3kwac	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63697	18041-20000-18964	14620 W PARTHENIA ST	91402	6	192B149     9	2638039020	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.22724	-118.45079	LED lighting retrofit project for (E) supermarket.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63698	17041-10002-19894	13058 W BLOOMFIELD ST	91604	2	165B161   480	2375013033	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	PIN	34.14900274	-118.41794951	Changes to approved set.  Use existing 200 amp panel with derated 150 amp main breaker.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63699	15041-20000-31494	2541 S DUNSMUIR AVE	90016	10	123B177   832	5043002004	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.0331	-118.35955	Plan check for a PV1 roof-mounted PV system. System size is 3.9 kWac and consists of (18) modules, (18) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63700	11041-10000-10424	"844 W 32ND ST BLDG ""A"""	90007	8	121-5A201   6	5123008016	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM	06/14/2011 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	34.02521	-118.28335	"New fire alarm system in BLDG ""A"" (Church).  The permit for Bldg ""B"" (Student Center) is issued under 11041-10001-10424."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63701	17041-10000-14811	15659 W SEPTO ST	91343	12	201B141    54	2661027012	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Issued	05/04/2017 12:00:00 AM	ADDRESS	34.25114	-118.47373	PC FOR PV SYSTEM ROOF MOUNTED 6KW AC 28 MODULES TOTAL.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63702	19041-20000-32571	10814 N VANALDEN AVE	91326	12	207B121   861	2718014001	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Issued	08/20/2019 12:00:00 AM	ADDRESS	34.26613	-118.54836	Plan check for PV roof mounted system, PV system size: 10.73KW DC  with 29 PV Modules and 1 inverter(10KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63703	14041-20001-14909	17401 W OSBORNE ST	91325	12	195B129   122	2768020001	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.23354	-118.51382	Fee for expedite only.*****New roof mounted PV system with optimizers and transformerless inverter.  Total system size 6.8KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63704	13041-10000-07336	9710 N WOODMAN AVE	91331	6	201B149   343	2644024025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.00, 1193.10	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.24628	-118.4474	ADDITION OF A COUPLE LIGHTING FIXTURES IN GROCERY MARKET. PC FOR T24 ENERGY COMPLIANCE FOR THE ENCLOSED SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63705	18041-20002-26119	145 S DOHENY DR	90048	5	138B169   497	4335007036	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.07395	-118.39001	3/14/2019changes to an approved set of plans.  changes noted delta 2 only.  changes to coincide with utility fault current level of 35kaic.this is plan check only.  ((((Plan check for a PV2 roof-mounted PV system. System size is 43.89 kWdc/37.86 kWac-CEC and consists of (3) 10 kWac rated inverters, (1) 7.6 kWac rated inverter, (1) load center, and (114) modules.Note: $0.00 permit fee due to CA Senate Bill 1222))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63706	18041-20000-34163	10837 W SHERMAN WAY	91352	2	183B173    85	2410019042	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.20	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM			Reviewed by Supervisor	10/17/2018 12:00:00 AM	ADDRESS	34.20136	-118.3671	Installation of distribution and manufacturing equipment for (E) industrial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63707	10041-20000-02487	2738 N HYPERION AVE	90039	4	151-5A205 230	5434036029	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	04/28/2010 12:00:00 AM		Permit Finaled	07/23/2010 12:00:00 AM	PIN	34.10778327	-118.27133995	Expanding existing market into adjecent space. New lighting and power. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63708	10041-10000-13118	10967 W SANTA MONICA BLVD	90025	5	129B153   608	4324030016	[Q]C2-1VL-O	West Los Angeles	Westwood			2655.20	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	09/08/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	34.04898	-118.44064	T24 lighting plan check only for remodel at a jack in the box restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63709	12041-10000-18930	2710 W TEMPLE ST	90026	13	138A203   229	5156023911	PF-1XL	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.07287	-118.27623	PV2. Plan check for new ground mounted 109.8 KW photovoltaic system for existing LAPD building. Inverter located on lower level.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63710	14041-20000-06184	12541 W BEATRICE ST	90066	11	105B161   940	4211006026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	33.98116	-118.41478	T24 FOR EXISTING NONHIGHRISE OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63711	13041-20000-19098	22300 W MULHOLLAND DR PV-2-BLDG 2	91364	3	165B101   186	2173001015	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	34.14916	-118.61059	PV-2? Plan check for PV system for church. Transformerless. One 27kW and one 20kW inverter for 47kW total. Roman Catholic Bishop of LA. Building 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63712	19041-10000-45797	11009 S FIGUEROA ST	90061	8	088-5A201 309	6075022027	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	33.93527	-118.28279	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63713	14041-20000-30447	18709 W RUNNYMEDE ST	91335	3	186B121   504	2118008010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.20576	-118.54089	PV1 SFD. TOTAL SYSTEM SIZE 7.74KW AC USING 36 MODULES. USING ENPHASE M215. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63714	18041-10000-24014	22004 W SHERMAN WAY	91303	3	183B101   122	2024001028	C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			06/27/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.20086	-118.60624	PLAN CHECK FOR TITLE 24 ONLY FOR - Tenant Improvement to (E) one-story, Type VB Bank Building.   Scope of work to include non-bearing partitions, finishes, ceiling and millwork, structural alteration to replace ATM machines. - TOTAL AFFECTED AREA = 7628 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63715	11041-10000-11655	8500 W BEVERLY BLVD #772	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			06/07/2011 12:00:00 AM	06/20/2011 12:00:00 AM		Permit Finaled	09/19/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT TO (E) RETAIL SPACE (#772):  (N) INTERIOR NON-BEARING WALLS, CEILING WORK, MILLWORK AND FINISHES TO CREATE SALES AREA, STORAGE AND RESTROOM.  (715 SF) plan chk s for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63716	17041-10000-03072	6555 W IMPERIAL HWY	90045	11	087B165   123	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.93206	-118.40322	PC for outdoor title 24 only. Removing HID fixtures and replacing with new LED ones. Area: 104,600.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63717	13041-10003-35881	431 W 7TH ST 5th floor-6th floor	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.04654	-118.25516	07/28/16Changes to an approved set of plans. All changes are clouded under Delta 25 & 26. Changes includes adding new circuit, relocating panels, receptacles, and light fixtures. New engineer for new scope of work under Delta 24 & 25. change of contractor on record((((Modifications to approved set based on architectural revisions.  Additional feeders to whirlpool panels by others.  (((PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT for Los Angeles Athletic Club. 5TH AND 6TH FLOOR. HISTORIC. TENANT IMPROVEMENT ON 5TH AND 6TH FLOOR OF 7 STORY HEALTH CLUB : NEW. LOCKERS, RESTROOMS, SHOWERS, SPA. & INSTALL  2 (N) STAIRCASE CONNECTING 5TH & 6TH FLOOR &  ADD. NEW RESTAURANT & BARBER SHOP & RETAIL STORE  TO (E) 6TH FLOOR.ALL overcurrent protective devices shall be series rating for 72kaic. Specification sheets to be provided to inspector in the field.BUILDING PC # 13016-10000-26283)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63718	13041-10000-09617	8801 N SARI AVE	91325	12	195B133   335	2688028041	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM	04/15/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	PIN	34.23033733	-118.50223118	ORIGNAL PERMIT ZONING CLEARED: 13041-10000-04814. CHANGED TO MICRO INVERTERS. PV1 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 7.25KW. [MICROINVERTER: ENPHASE M215-Z.] [SOLAR MODULE: TRINA SOLAR TSM-250 PC/PA05.08]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63719	18041-10000-08731	8985 W VENICE BLVD B	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.02733	-118.39241	PC FOR TITLE 24 ENERGY ONLY FOR INTERIOR NON STRUCTURAL TI TO (E) RESTAURANT.SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS IN RESTROOM. TOTAL AFFERCTED AREA 121 SQ.FT.B#18016-10000-02675	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63720	15041-10000-09585	9140 N O'MELVENY AVE	91352	6	198B165   352	2629015050	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.23551	-118.40305	PV1 4.2kW roof-mounted system with (1) Powerone PVI4.2 OUT-D inverter, and (13) (SunPower SPR 327NE interconneting through the main service panel.-Applicant is aware of online service, but insist to do plan check over the counter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63721	16041-20000-10554	5757 W WILSHIRE BLVD Ste 204	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 13,200 sq. ft.Note: Building permit has been pulled under 16016-10000-02981	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63722	11041-10001-27566	21031 W VENTURA BLVD 101	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM			PC Approved	01/05/2012 12:00:00 AM	PIN	34.16717222	-118.59179488	Revision to approved plans to show revise T24 calculation for new lighting and emergency lighting Dental Office Tenant Improvement. Plan check for Power & Energy. Permit was issued 11041-90000-18640	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63723	15041-20000-31425	1316 N WESTERN AVE	90027	13	147A193   240	5544031018	C2-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			Corrections Issued	09/22/2015 12:00:00 AM	ADDRESS	34.09543	-118.30905	Plan check for Title 24 only for existing space. Total area: 3,580 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63724	14041-10000-05299	959 N SEWARD ST	90038	4	144B185  1065	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Closed	12/22/2015 12:00:00 AM	ADDRESS	34.08878	-118.33338	PLANCHECK FOR TEMPORARY POWER ONLY FOR 3 BUILDINGS.EAST BUILDING: 959 NORTH SEWARD STREET LOS ANGELES, CA 90038BUILDING PERMIT # 13010-10000-01379WEST BUILDING: 6555 WEST BARTON AVENUE STREET LOS ANGELES, CA 90038BUILDING PERMIT # 13010-10000-01378PARKING STRUCTURE: 6624 WEST ROMAINE STREET LOS ANGELES, CA 90038BUILDING PERMIT # 13010-10000-01374	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63725	13041-10001-15329	823 N SEWARD ST	90038	4	141B185   144	5533024029	[Q]MR1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	34.08594	-118.33326	CHANGES TO APPROVED: DELTA 2-8. Changes to lighting and some more receptacles added (changes on plan include UL listed fixture and service rated disconnect for building).PLAN CHECK POWER AND ENERGY FOR INTERIOR T.I. 2-STORY COMMERCIAL BUILDING. LOCATION IN METHANE BUFFER ZONE. NO METHANE MITIGATION REQUIRED PER METHANE REPORT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63726	13041-10000-17047	11999 W SAN VICENTE BLVD SUITE 450	90049	11	129B141   174	4404025029	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM			PC Approved	06/27/2013 12:00:00 AM	ADDRESS	34.05246	-118.47261	PLAN CHECK FOR OFFICE BUILDING. FLOOR REMODEL/TENANT IMPROVEMENT FOR EXISTING TENANT. SCOPE OF WORK < 400 A. LOCATION IS NOT A HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63727	17041-10000-02263	1560 W YOSEMITE DR	90041	14	159A227     5	5689028905	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.13274	-118.20021	PC for outdoor Tile 24 only. Remove HID fixtures and replace with new LED fixtures. Area: 29,325.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63728	14041-10001-32569	3323 S CLUB DR	90064	5	123B165   761	4316025013	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			Reviewed by Supervisor	12/11/2014 12:00:00 AM	ADDRESS	34.03234	-118.40276	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL  10.71 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(2) INVERTERS: SOLAREDGE SE5000A-US-ZB-U  (42) MODULES: KYOCERA KD255GX-LFB3>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63729	13041-10000-22260	15611 W VANDORF PL	91436	5	165B141   477	2285007031	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Reviewed by Supervisor	08/27/2013 12:00:00 AM	ADDRESS	34.14509	-118.47399	PV1 14.81 KWdc 240V XFRMless. 2 STORY. nonSTD. ROOFMOUNT.  [( 2 ) INV: PVI-5000-OUTD-US and PVI-6000-OUTD-US ] [( 57 ) MOD: BenQ #PM250M01-260W ]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63730	19041-20000-52526	6320 N CANOGA AVE STE 910	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	01/02/2020 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.18499	-118.59722	T24 PLAN CHECK ENERGY ONLY, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 1735 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63731	15041-20000-03122	11601 W WILSHIRE BLVD 15TH FLOOR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	PIN	34.0509267	-118.45996763	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR OFFICES. 5408 SQFT, EMERGENCY LIGHTING.  15TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63732	11041-20000-05579	300 S GRAND AVE 7th Floor	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Finaled	03/20/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to a high rise building.  Install general lighting in partial of 7th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63733	11041-10000-19030	5990 N SEPULVEDA BLVD #550	91411	2	177B145   487	2243019023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.17911	-118.46588	T.I. NON-BEARING INTERIOR WALLS IN EXISTING OFFICE.Plan check for T-24 lighting compliance and emergency ltg. and exit signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63734	19041-10000-25774	4560 N CARPENTER AVE	91607	2	168B169   893	2364006001	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.15365	-118.39089	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF CENTRAL INVERTER(SE7600H-US) WITH 22 MODULES USING P400 OPTIMIZERS AND ESS(TESLA POWER WALL) CONNECTECTED TO EXISTING NEW 225A SERVICE SERVICE PANEL NOT INCLUDED AS PART OF SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63735	19041-10000-10654	14122 W AETNA ST	91401	6	177B153   813	2240026010	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Issued	03/26/2019 12:00:00 AM	ADDRESS	34.18007	-118.44079	Remove HID fixtures and replace with new LED fixtures (Indoor Only), - T/24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63736	14041-10004-14508	1825 N BRONSON AVE	90028	13	150A191   280	5586027006	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM			PC Approved	12/16/2014 12:00:00 AM	ADDRESS	34.10425	-118.31823	Changes to approved set. Removal of 2 devices. Addition of 1 new device. (((12/16/14)))Changes to approved set.  192 new fire alarms.(148) NEW DEVICES.  ONE NEW PANEL / PERMIT WAS PULLED UNDER 14041-10000-14508. PLAN CHECK ONLy (((((((((((((((((((((    addition of 80 new devises.))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63737	12041-20000-26053	9657 N GIERSON AVE	91311	12	201B101   423	2727010002	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.2457	-118.61172	PV 1. Plan check for PV single family dwelling. 4.165kW DC. Transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63738	15041-20001-39125	18133 W VENTURA BLVD #1	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	(2/28/2017)changes to an approved set of plans.  changes to orientation of light fixtures to reflect field conditions.  This is paln check only.(((T.I. at (E)portion of medical office on 1st floor. PC for Power and Energy per art. 517.   Total area: 9,778 sq.ft . suite # 1)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63739	18041-20000-15862	11600 N ELDRIDGE AVE	91342	7	213B169  1017	2530001018	(T)RU-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Issued	04/30/2018 12:00:00 AM	ADDRESS	34.28073	-118.38369	Site lighting for private street.  Plan check for energy - 65,625 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63740	18041-10000-44884	6636 W VALMONT ST	91042	7	202-5A203  17	2570008038	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.25148	-118.27693	PLAN CHECK FOR A ROOF MOUNTED 6.4 KVA SYSTEM CONSISTING WITH 20 MODULES AND (1) 320 VA RATED MICRO INVERTER(IQ7X-96-2-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63741	14041-20000-35853	20524 W GERMAIN ST	91311	12	207B109   568	2707012021	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.26155	-118.58078	PV1. Install roof mounted PV system sized 10 kW. Interconnected with main service pannel.(34) Sunpower SPR-327NE Modules(1) Sunnyboy SB3000 Inverter(1) Sunnyboy SB7000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63742	14041-20000-17367	7036 N VAN NUYS BLVD	91405	6	183B149   254	2217007018	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Closed	10/23/2017 12:00:00 AM	ADDRESS	34.1987	-118.44853	Power and energy plan check for 5 stories new built with 132 units assisted  living apartment without kitchens, central kitchen included.  2008 TITLE 24  CODE CYCLE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63743	16041-10001-37053	746 S CENTRAL AVE	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM			PC Approved	11/15/2016 12:00:00 AM	ADDRESS	34.03537	-118.24198	PC FOR ENERGY. REMOVE (E) LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES.  LED. TOTAL AREA 258328 SQ FT. PERMIT HAS BEEN PULLED UNDER THE MASTER  APPLIVCATION,	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63744	16041-10000-34235	1641 S PREUSS ROAD	90035	5	129B169   717	4305020900	OS-1XL-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	07/31/2020 12:00:00 AM	ADDRESS	34.04927	-118.38467	PC FOR POWER AND ENERGY. THE ROBERTSON RECREATION CENTER PROJECT SERVICE SIZE 800A TO BE RELOCATIN. TOTAL SIGHT SITE AREA 12696 SQ FT.B# 16016-10000- 04226	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63745	17041-10000-17965	801 S FIGUEROA ST 10TH FLR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM			Corrections Issued	05/30/2017 12:00:00 AM	ADDRESS	34.04789	-118.26153	PC for T24 for TI in bathroom of existing office space. PC for lights.Total area is 640sqft. Load is under 400 A. Building # 17016-10000-14050.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63746	16041-20001-36812	10600 N SEPULVEDA BLVD	91345	7	207B145   458	2649011022	P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.26279	-118.46696	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 48 kWac and consists of (4) inverters, (186) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63747	10041-20000-05785	10690 N LAUREL CANYON BLVD	91331	7	207B153   409	2618002026	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Pacoima		1044.02	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	04/08/2010 12:00:00 AM	ADDRESS	34.26464	-118.43801	T.I WORK IN STORE (7 ELEVEN). THE PLAN CHECK IS POWER AND LIGHTING. EXISTING PERMIT ON 10041-20000-05885 AND 10041-20000-02200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63748	13041-10000-07811	244 S AVENUE 18	90031	1	138A219   165	5447025021	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			03/27/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.07044	-118.22153	NEW CONSTRUCTION OF 6 APARTMENT BUILDING. PC FOR POWER AND ENERGY. NEW 600 A RATED EQUIPMENT. TOTAL AREA 7795 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63749	10041-10000-18526	2029 S CENTURY PARK EAST	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	01/21/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI , adding new panel and a transformer on n12 floor.  Plan check for title 24 and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63750	15041-20000-03018	12481 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	33.9791	-118.41047	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63751	18041-10000-14721	4536 N KATHERINE AVE	91423	4	168B153   704	2265017039	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.15407	-118.4431	Install New rooftop solar system  on (E) SFD, 5.76 kW DC/ 5.136 kW AC system with (16) AC modules, (1) 100A combiner panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63752	18041-10000-11013	2905-2931 W EXPOSITION PL	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	12/13/2021 12:00:00 AM	ADDRESS	34.02038	-118.3277	PC for power and energy for 12 unit three story apartments. Installing new 600A service, 12 unit panels, lights, receptacles and equipment. All units located in lots 9 and 10 see E1.1.NOTE: PC TO ASK FOR OUTDOOR LIGHTING T24 FORMSB#18010-10000-00133 NEW THREE-STORY, 12-UNIT APARTMENT BUILDING (BLDG 9/10, TYPE 400) WITH GROUND-LEVEL 2-CAR GARAGE AT EACH UNIT PER DIR-2016-3899-SPPA-SPP-SPR.**9 OF 14**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63753	10041-20000-06983	888 S FIGUEROA ST BASEMENT	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	07/19/2010 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI IN AN EXISTING OFFICE AREA IN THE BASEMENT AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS. PERMIT IS FOR NEW PANEL AND NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63754	14041-20001-32513	11515 N SPROULE AVE	91331	7	213B161   721	2532006010	A2-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			PC Approved	01/02/2015 12:00:00 AM	ADDRESS	34.27889	-118.40731	expedite per customer request.pv1install roof mounted pv system sized 10.0kw interconnected with msp.(34) sunpower 327w modules(2) powerone pvi 5k transformerless inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63755	14041-10000-30464	500 S SANTA FE AVE	90013	14	126A217   245	5164004010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.04107	-118.23124	4,000 Amp Service for new office Building. NEW 4-STORY W/ MEZZ. OFFICE BLD'G. 98,825 S.F. (4-STORY TYPE IIB OVER 1-STORY TYPE IA)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63756	17041-10000-45974	21730 W MARILLA ST	91311	12	201B105   153	2746016021	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.24747	-118.60279	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63757	19041-10000-41015	14724 W VENTURA BLVD 101	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Issued	10/21/2019 12:00:00 AM	ADDRESS	34.15162	-118.45395	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI IN AN EXISTING OFFICE SPACE, GROUND FLOOR OF A HIGHRISE. SCOPE OF WORK IS NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 7014 SQFT. B#: B19LA18120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63758	19041-10000-02750	5359 E VALLEY BLVD	90032	14	139-5A237  90	5220033023	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	03/19/2024 12:00:00 AM	ADDRESS	34.07473	-118.16674	NEW INDOOR NURSERY. NEW SERVICE: 4,000 AMP, 277/480V, 3PH. AREA: 31,136 SQR FT.BUILDING PERMIT: 18016-10000-40987 HAS NOT BEEN ISSUED YET.((FEE ESTIMATE ONLY))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63759	17041-10000-23184	777 S ALAMEDA ST	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.03396	-118.24117	ELEVATOR SHAFT AND LOBBY UPGRADES. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63760	10041-20000-15684	8141 S GULANA AVE	90293	11	096B153     1	4115021800	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	04/11/2012 12:00:00 AM	ADDRESS	33.96169	-118.43753	PLAN CHECK POWER TO INSTALL A NEW WASTEWATER COOLER, TO REPLACE (E) PROCESS PIPING, INSTRUMENTATION AND CONTROLS IN HAZARDOUS CLASSFIED AREA. LOW VOLTAGE WIRING NOT PLAN CHECKED. PERMIT INCLUDES LOW VOLTAGE WIRING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63761	17041-10001-44085	950 W 76TH ST 1-50	90044	8	099B197   208	6020009032	C2-1VL	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	Apartment			11/21/2019 12:00:00 AM			PC Info Complete	11/21/2019 12:00:00 AM	ADDRESS	33.97053	-118.29106	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 1. SCOPE OF WORK INCLUDES DOWNGRADING SERVICE SIZE FROM 2000A TO 16000A, ALL DOWNSTREAM FAULT CURRENT CALULCTIONS WERE UPDATED AND VERIFIED. NO NEW EQUIPMENT WAS ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63762	16041-30000-15555	18221 S DENKER AVE	90248	15	063B193   282	6108003053	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	33.86487	-118.30498	Plan check for a PV1 roof-mounted PV system. System size is 5.5 kWac and consists of (22) modules, (22) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63763	16041-10000-28126	1755 N HIGHLAND AVE	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.10323	-118.33897	PC FOR TI 24 ONLY FOR TENENANT IMPROVEMENT WITH 1523 SQFT. CONVERTING OFFICE AREA INTO MULTIPLE OFFICES USING PARTITIONING WALLS. INSTALLING NEW LIGHT FIXTURES AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63764	14041-10002-19839	500 WORLD WAY 4thFloor	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM			PC Approved	06/02/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	((((6/2/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE MODIFICATION IN LIGHTING FIXTURE TYPES AND ADDING NEW LOADS TO EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY. DELTA 5 INDICATES ALL THE CHANGES. Changes to approved set.  Full plan check revised by adding one 24KW water heater and  one 70-Amp  panel.  All changes clouded and marked with delta-4 only.*****Previous Work Description*****plan check for power and energy. 4th floor. Delta airline Terminal 5 SKYCLUB Renovations. Changes include clarifications on T24 and 100% rated breakers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63765	12041-20001-19726	20730 W DEARBORN ST B and C	91311	12	198B109   156	2748037022	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.23712	-118.58532	Modification to previously approved set of plans.       <<<<Plan check for energy and emergency lighting. Units B & C. 21290 sqft,>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63766	17041-20000-35569	9310 W HILLROSE ST	91040	7	207B185   652	2547021043	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.2622	-118.33421	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63767	17041-10000-16175	1050 S GRAND AVE Suite 200	90015	14	127-5A207 345	5139010***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.04171	-118.26155	Plan check for power and Title 24.  Change of use from retail to dental office in mixed use highrise building.  New 75 kVA transformer and new 225 amp subpanel feeding new lighting and receptacles.  Total area = 1,246 sq. ft.       Building permit #17016-10000-11257	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63768	17041-10000-41266	1370 N ST ANDREWS PL	90028	13	147A193   175	5544030056	(Q)C2-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM			PC Info Complete	11/14/2017 12:00:00 AM	ADDRESS	34.09641	-118.31076	PC FOR ENERGY ONLY FOR A NEW IRRSHAPE OFFICE BUILDING. TOTAL AFFECTED AREA IS 1162 SQ.FT. B#17010-10000-04088	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63769	15041-20000-39763	5800 W SUNSET BLVD PHASE 1	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENTS FOR TV STUDIOS AND ASSOCIATED SUPPORT SPACES..  PHASE 1 of 5 PHASE PROJECT FOR STAGE 6 AND BUILDINGS 16. STAGE 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63770	17041-10001-42471	531 N SIERRA BONITA AVE	90036	5	141B177   992	5526027005	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.08116	-118.35439	expedite per applicant requestNEW ROOFTOP SOLAR SYSTEM CONSIST OF 33 MODULES (LG LG360N2W-G4) AND 33 MICROINVERTERS (ENPHASE IQ6-60-X-US).  SYSTEM SIZE IS 11.88KWdc and 7.92KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63771	18041-20000-44018	21902 W DEVONSHIRE ST	91311	12	204B101   187	2747016042	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.257	-118.60514	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a change of use from bank to dental office. Work includes 400A Service a total lighing area of 3,432 sq. ft.Note: Building application has been generated under 18016-10000-05620	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63772	17041-10000-35844	300 WORLD WAY #330-331	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	"Install New sign lights on Terminal 3 space #330&331, sign reads: ""Soundstage market by Hudson"" and ""Moshi"" respectively. Total area: 5.75 sq.ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63773	11041-10000-13149	6914 W FOOTHILL BLVD	91042	2	202-5A201 616	2564005013	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM	08/08/2011 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.24757	-118.2822	First time tenant.  Laundromat in a single story building.  Everything is new.  Full Plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63774	17041-10000-16029	2049 S CENTURY PARK EAST #700	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY ONLY. TENANT IMPROVEMENT, NEW LIGHTING AND POWER ON OFFICE BUILDING. 4745 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63775	13041-20000-02472	4166 W MELROSE AVE	90004	13	141B197   511	5539022033	[Q]C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM			PC Approved	01/31/2013 12:00:00 AM	PIN	34.08342296	-118.29132504	Remodel and new addition of 557 sq. ft. to an existing McDonald's Restaurant.  Load is less than 400 amps and occupancy load is less than 90.  Change to lighting, receptacles, loads.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63776	15041-20000-41522	5658 N CAHUENGA BLVD	91601	2	174B177   372	2415025012	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.17371	-118.36136	TI to existing commercial building (juice  bar/restaurant). Plan check for energy only. Adding new lighting. Total sqft. 398.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63777	19041-10000-31719	4427 S GRAND VIEW BLVD	90066	11	108B157   376	4232022008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	33.9942	-118.42167	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE6000H-US) WITH 18 MODULES USING P400 OPTIMIZERS AND 1 ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63778	19041-10000-34005	1771 W BLAKE AVE BLDG 7	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Reviewed by Supervisor	09/30/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	7 OF 11. BLDG 7POWER PLAN CHECK FOR 800A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDINGS AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63779	13041-10000-32190	68 S FREMONT PL	90005	4	132B185   344	5090020013	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.05886	-118.32703	Roof mounted PV system with 17KWdc, 52 modules, two combiner boxes, two 7500 watts inverters., and one 200A panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63780	16041-20000-03635	19550 W VANOWEN ST	91335	3	180B117    20	2132001010	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Issued	02/02/2016 12:00:00 AM	ADDRESS	34.19362	-118.55961	PV1.  Install 8.82 kW DC roof-moutned, utility-interactive PV system.  (28) modules with (1) transformerless inverter with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63781	17041-20001-45031	21021 W VENTURA BLVD	91364	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.16688	-118.59113	Revisions to approved set of plans.  Relocation of equipment relative to original design.  Changes clouded and identified. (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from office to beauty salon/tenant improvement. Total lighting area = 6,815 sq. ft.Note: Building application has been generated under 17016-20000-36905)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63782	10041-20000-12992	6828 N VAN NUYS BLVD	91405	6	183B149   704	2217009016	(Q)RAS4-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Apartment			07/07/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	34.19475	-118.44846	NEW MIX USE 68 UNIT APT BLDG plans expired and changed it droped from 96 units to 68 all remaining units still the same all common area are the same no change feeders panel schedules are the same service partially changed building plan check changed the fee to about 50% of original fees therfore using the same old plans a reduction of fee is giving similar to building plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63783	14041-10001-04104	1260 N VINE ST	90038	13	144B189   143	5534001400	C2-1-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.09406	-118.32645	This is a one story bldg, title 24. fast food. 3-6-14  mz  lighting changed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63784	15041-10000-27857	1130 S ABBOT KINNEY BLVD	90291	11	108B145  1164	4238003025	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	33.99144	-118.46965	PC FOR ENERGY ONLY, T-24 TO A COMMERCIAL RETAIL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2216THIS IS CHANGES TO APPROVED SET. ORIGINAL SET 15041-10000-15634	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63785	17041-20000-34083	6922 W HOLLYWOOD BLVD Suite #108	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL STORE. 4940 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63786	15041-10000-31734	100 WORLD WAY TERMINAL 1-LV 1-ROOF	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	REPLACING 600 DEVICES TO AN  (E) FIRE ALARM SYSTEM IN LAX TERMINAL 1 LV1.  ADDING 1 GRAPHIC ANNUNCIATOR, 9 REMOTE POWER SUPPLIES AND 600 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63787	17041-10000-13830	820 S SEASIDE AVE	90731	15	015B205    18	7440032904	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.73609	-118.27024	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  18900 SQ FT. OUTDOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63788	10041-10000-10916	1111 S FIGUEROA ST	90015	9	127-5A207 151	5138016913	C2-4D-O	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	08/06/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.04338	-118.26581	New Video board for staples center. New feeders, panels, Xformer, and circuites. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63789	16041-10000-08257	4256 S SAN PEDRO PL	90011	9	114A205   255	5113020009	R2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Expired	05/18/2018 12:00:00 AM	ADDRESS	34.00633	-118.27084	PV1 rooftop solar installation 6kW system.  (20) SPR-327-NE-WHT      (1) SB6000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63790	17041-10000-05604	14846 W FRIAR ST	91411	6	178-5A149  14	2241008011	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Apartment			02/21/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.18551	-118.45707	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS FOR AN APARTMENT BUILDING IN CORRIDORS, AND PARKING GARAGE. TOTAL AFFECTED AREA IS 6635 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63791	18041-10000-32113	11126 S MAIN ST	90061	8	087A205    53	6073017018	C2-1VL	South Los Angeles	Southeast Los Angeles			2411.10	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Issued	09/06/2018 12:00:00 AM	ADDRESS	33.93411	-118.27371	Install a new Fire Alarm System with 61 Devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63792	18041-10004-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.26056	-118.35206	PC FOR CHANGES TO APPROVED SET TO REFLECT ADDITION OF DISCONNECT TO ESS SYSTEM.SLD AND PLACARD HAVE BEEN REVISED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63793	12041-20000-15857	6430 N INDEPENDENCE AVE	91367	3	180B109   591	2149003036	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.18736	-118.59042	T-24 lighting plancheck	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63794	19041-10000-13404	3585 S VERMONT AVE	90007	8	120B197   796	5040028028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.0239	-118.29174	plan check for title 24 only for change of HID to LED lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63795	14041-10000-25330	12847 W ARROYO ST	91342	7	219B161   277	2525018056	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			Reviewed by Supervisor	10/28/2014 12:00:00 AM	ADDRESS	34.29437	-118.41265	Installation of 21 kWac roof mounted solar PV system.  90 modules and 3 inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63796	16041-20000-05919	5252 N WILLOW CREST AVE	91601	2	171B177   402	2416028026	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Apartment			02/19/2016 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	34.16637	-118.362	4 story, 25 unit apartment building with 1 level of subterranean parking garage.  Plan check for power and energy.Variance to separate fire alarm plans submitted 02/19/2016.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63797	15041-10001-43830	24105 S FRAMPTON AVE	90710	15	039B197    42	7439011038	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	33.805	-118.29924	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63798	10041-10000-03792	2025 S AVENUE OF THE STARS 1st Floor	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM			PC Info Complete	03/15/2010 12:00:00 AM	ADDRESS	34.05715	-118.41482	on the first floor of theHyatt Century Plaza Hotel, replacing the luminaires in the the barrooms of Constellation Room, the Olympic Room, and the Westside Rooom.  The dimmer panel in the Westside Room was replaced . All branch circuits are existing.plan chk is for title 24 and 3 ea emergency ckts  See existing permit 10041-10000-00558.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63799	12041-20000-25148	714 S BRISTOL AVE	90049	11	129B141   628	4266003034	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2012 12:00:00 AM			PC Approved	12/06/2012 12:00:00 AM	ADDRESS	34.04547	-118.48064	NEW SINGLY FAMILY DWELLING RESIDENTIAL. SERVICE IS 600 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63800	13041-20000-25973	6801 S PARK TER	90045	11	102B165   126	4104001082	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	33.97698	-118.39328	T24 FOR EXISTING PHYSICAL THERAPY OFFICE. SCOPE OF WORK IN OFFICE AREA. TOTAL SQRFT 2600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63801	18041-20001-00407	13442 W CORCORAN ST	91340	7	213B157   257	2524019009	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM			PC Approved	01/15/2018 12:00:00 AM	ADDRESS	34.282	-118.42542	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consits of (2) inverters, (38) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63802	19041-20000-04622	4219 N VANALDEN AVE	91356	3	165B117   377	2180007001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.1464	-118.55701	pc for pv system. system size 7300W-DC, 7600W-AC. 21 modules (LG350Q1C-A5). 1 INVERTER (NINGBO SOLIS -1P7.6K-4G-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63803	19041-20000-41380	11849 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63804	14041-10000-23351	10000 N COMMERCE AVE	91042	7	202-5A199 159	2568007037	C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	05/26/2015 12:00:00 AM	ADDRESS	34.25036	-118.28843	Plan check for power only.  Replace existing generator and ATS with new outdoor 175 kW generator with a diesel particulate filter for emergency power for a data center.  600 A ATS/MTS with bypass-isolation included.  New 600 A 208Y/120V sub-panel shall be provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63805	13041-10000-35434	670 S WESTERN AVE	90005	10	132B193   229	5093006029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.06027	-118.30891	PLAN CHECK FOR (E) RALPHS STORE. PROJECTED LIGHTING AREA IN SCOPE OF WORK IS APPROX. 46,349 SQ FT. AREA. SERVICE IS EXISTING. REMOVING SOME (E) LIGHTS AND REPLACING WITH NEW DECOR ACCENT LIGHTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63806	18041-10000-00545	19331 W BLYTHE ST	91335	3	189B117   397	2105013012	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			Reviewed by Supervisor	02/09/2018 12:00:00 AM	ADDRESS	34.21496	-118.55494	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 34 MODULES ( HANWHA Q-CELL. Q PEAK-G4.1 300), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS 320W) WITH A CENTRAL INVERTER (SOLAR EDGE SE10000A-US).  SYSTEM SIZE IS 10.88 KWdc AND 10 KWac.PLANCHECKER TO VERIFY CONTRACTOR INFO	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63807	19041-20000-12586	1000 W WILSHIRE BLVD unit 560	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.05085	-118.26078	ti to an existing commercial building.  adding new lighting new controls to exsisting panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63808	17041-20000-36006	3866 S CRENSHAW BLVD	90008	10	117B185   941	5033003002	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.01531	-118.33473	Plan check for energy only. TI/Change of use from retail to restaurant. New lighting (incl. emergency) - 1,694sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63809	16041-20004-40556	338 N PATTON ST	90026	1	135A209    20	5160009003	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			10/09/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	05/03/2021 12:00:00 AM	ADDRESS	34.06615	-118.25849	10/9/19CHANGES TO APPROVED SET DELTA C AND D ONLY. ADD NEW LOADS, PANEL, RELOCATION OF UNDERGROUND PULL SECTION, AND LIGHTS. <<<<Plan check for power and energy New appartment Builing 44 units 5 story Service size: 1600A. Total area: 42,026 sq ft located in a Methane zone.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63810	10041-10000-09526	1200 W 7TH ST 5th Floor	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.05136	-118.26616	TI IN AN EXISTING COMMERCIAL SPACE ON THE 5th FLOOR. PLAN CHECK IS FOR POWER & ENERGY.Variance to separate fire alarm plans was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63811	18041-20000-21369	18537 W PARTHENIA ST	91324	12	195B125   834	2770018019	M1-1, M1-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.22838	-118.53759	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES. 70,200 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63812	17041-10003-37515	1400 N CAHUENGA BLVD	90028	13	147A187   280	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	34.09641	-118.32933	ADDITION TO EXISTING KITCHEN IN ROOM C109;NEW KITCHEN EQUIPMENT AND LUMINAIRES;REVISED TITLE 24 COMPLIANCE FORMS;UPDATED LOAD ON SWBD MS AND SHORT CIRCUIT ANALYSIS TO INCLUDE NEW PANELS AND TROUGH.delta 3 and 4 changes((((((((FULL PC FOR POWER AND ENERGY. NEW 8 STORY HOTEL WITH RESTAURANT AT GROUND FLOOR (CORE&SHELL ONLY) AND TOP LEVEL AMENITY WITH THREE SUBTERRANEAN GARAGE BASEMENTS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63813	17041-10001-27335			15	021B193    39	7445004242	(Q)C2-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			08/07/2017 12:00:00 AM			PC Approved	08/14/2017 12:00:00 AM	PIN	33.75477294	-118.30875089	Plan check only for T24 for existing office spaces, , no common area is touched in this scope. Area 813 sq.ft. Permit issued under 17041-40000-27335, this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63814	16041-20000-43300	23033 W OXNARD ST	91367	3	177B097   492	2039008027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Issued	12/23/2016 12:00:00 AM	ADDRESS	34.17934	-118.62858	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.4KW. CENTRAL INVERTERS$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63815	14041-20000-08639	1149 S HILL ST	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.03926	-118.26099	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 1ST FLOOR LOBBY AREA. SUITE 101. 1470 SQFT, EMERGECNY LIGHTING. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63816	16041-20000-21143	400 S HOPE ST LVL 24	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 5112SQFT.  HIGH RISE.  LEVEL 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63817	14041-10001-11720	2512 S WESTWOOD BLVD	90064	5	126B157  1115	4255026002	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.03878	-118.42719	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{ PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZEER. 18 MODULES. 1 INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63818	14041-10001-23528	14612 W VENTURA BLVD	91403	4	166-5A151 119	2276001016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM			PC Approved	04/30/2015 12:00:00 AM	ADDRESS	34.15118	-118.45135	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 1 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO THE ENERGY CALS AND LIGHTING FIXTURES.TI FOR A RESTAURANT.  NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTING.PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63819	11041-20000-11995	14141 W VENTURA BLVD	91423	5	165B153   388	2265020006	(T)(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	10/03/2011 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	NEW STORY 4 STORY COMMERCIAL/113 UNIT RESIDENTIAL MIXED USE BUILDING. TWO SERVICES SERVING BUILDING. PLAN CHECK IS FOR POWER AND ENERGY.  APPLICANT HAS FILED FOR VARIANCE TO SEPERATE FIRE ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63820	16041-20000-00998	831 E 3RD ST	90012	14	129A215   260	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM			Corrections Issued	01/12/2016 12:00:00 AM	PIN	34.04615	-118.23543171	Plan check for Title 24 only in existing space T.I. Total area: 2,742 sq ft. Total load less than 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63821	18041-20002-12011	9336 W WAYSIDE DR	91040	7	207B185   522	2549017009	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.26102	-118.33471	Relocation of equipment to lower level below main house.  LAFD approval obtained for relocation.$0 plan check fee per State Senate Bill SB 1222.(((Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (35) modules. System is interconnecting with a 400-amp service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63822	17041-10000-21981	2700 W COLORADO BLVD 254	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.14248	-118.22438	PC FOR POWER AND ENERGY FOR CHANGE OF USE  FROM 'M' TO 'A3' AND TENANT IMPROVEMENTS FOR A HEALTH CLUB.NEW 600A  SWITCH BOARD FEEDING FROM (E) 3000A SWBD.SOCPE INCLUDE NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 17014 SQ.FT BL# 17016-10000-17796	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63823	17041-20001-15690	19130 W CHARLES ST	91356	3	168B121   226	2176031008	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.15733	-118.55007	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63824	18041-20000-28914	13142 W DEWEY ST	90066	11	114B149   277	4247006007	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.0105	-118.45393	pv1install roof mounted pv system sized 12.96 KW AC interconnected with msp.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63825	15041-10000-26558	2354 W 30TH ST	90018	10	120B189   411	5052005024	R1-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.10	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.02727	-118.31964	PV1 ROOF MOUNTED SOLAR SYSTEM FOR A SINGLE FAMILY DWELLING. (1) INVERTER 3.6 KW, (20) MODULES. INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63826	18041-20000-31255	7900 N BALBOA BLVD BLDG  E	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Issued	11/07/2018 12:00:00 AM	ADDRESS	34.21347	-118.50092	"Plan check for power and energy for new Aircraft Hangar Building ""E"" 2 story with office space in Van Nuys Airport, Service Size: 1200A 120/208V. Total area: 15,840 sq ft. B#17010-20000-04905"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63827	18041-10000-14502	6615-6619 W HOLLYWOOD BLVD	90028	13	148-5A185 121	5547004004	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	02/25/2021 12:00:00 AM	ADDRESS	34.10174	-118.33395	Energy plan check for a change of use from retail to restaurant. total area is 10,500 SQ FT. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63828	18041-20000-33317	5252 N WILLOW CREST AVE	91601	2	171B177   402	2416028046	R3-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Apartment			08/30/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	12/08/2020 12:00:00 AM	ADDRESS	34.16637	-118.362	Plan check for a fire alarm system for a 4-story, 25-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (78) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63829	09041-10001-17130	517 W 7TH ST	90014	14	129A209   142	5144004035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM			Corrections Issued	02/10/2010 12:00:00 AM	ADDRESS	34.04706	-118.25596	refurbished 4-stories building with  floors 1 thru 3 to be commercial tenants and the 4th fl to be a residence.plan chk is for  shell and core and the 4th fl residence((((((((((((((((((((((((((  New supplemental application is for changes from new application-------------  two services, section adding two panels and 3 rtu. ))))))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63830	14041-20000-28680	600 W WILSHIRE BLVD suite 750	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.04796	-118.25622	Plan check for energy only. TI to existing office on 7th floor of existing high rise office building.6,760sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63831	15041-20000-11932	6250 N TOPANGA CANYON BLVD 1585	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for power and Title-24 (energy).  Total area = 2,200 sq. ft.T.I. to retail first time tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63832	17041-20000-04511	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.10158	-118.3062	Plan check for energy only. Interior TI of (E) restaurant. New lighting (incl. emergency). 2,862sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63833	13041-10000-30230	4325 W CEDARHURST CIR	90027	4	150B201    77	5591007008	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.11125	-118.28413	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING WITH EXISTING 200A MAIN. WORK IS DONE ON A MICROINVERTER STANDARD PLAN, WITH 24 MODULES (LG; LG-260S1C) AND 24 ENPHASE MICROINVERTER (M215).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63834	17041-20000-16010	14419 W RIVERSIDE DR	91423	4	169-5A151 202	2248005018	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	06/29/2023 12:00:00 AM	ADDRESS	34.15784	-118.44721	Plan check for power and energy. Project site is a new 3-story apartment building.fire alarm variance has been submittedNote: Building application has been generated under 16010-20000-05878	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63835	17041-20000-20395	333 S GRAND AVE LEVEL 1	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	PLANCHECK FOR T24 ENERGY. TI FOR PORTION OF 1ST FLOOR, CHANGE OF USE FROM LOBBY TO CAFE, 2756 SQFT.BUILDING PERMIT: 17016-10000-15847	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63836	14041-20000-23821	4810 N BALBOA AVE	91316	5	168B133   256	2289019151		South Valley				1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	PIN	34.15777393	-118.50295447	PV1.  Install 9.00 kW roof-mounted, utility-interactive PV system.  400A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63837	16041-10000-04364	12438 W EMPIRE PL	91331	7	207B165   218	2536029002	RS-1	North Valley	Arleta - Pacoima	Pacoima	YES	1047.04	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.2624	-118.4047	PV1, rooftop solar installation 4.5kW AC(18) SW 285 Mono(18) Enphase M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63838	16041-10000-40951	823 S LOS ANGELES ST	90014	14	127-5A211 308	5145014005	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			11/18/2016 12:00:00 AM			PC Info Complete	09/06/2017 12:00:00 AM	ADDRESS	34.04159	-118.25312	Plan check for power and Title 24.  Adaptive reuse of 4 story mercantile building.  Change of use on ground floor to 3 retail units and upper floors to 12 live/work units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63839	11041-10000-23753	4300 N GRIFFIN AVE	90031	1	145-5A225 379	5303006001	[Q]C1-1XL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM			PC Approved	11/07/2011 12:00:00 AM	ADDRESS	34.09207	-118.2038	T.I. to Walk-in-cooler, Kitchen and Bathroom only for an existing Grocery store.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63840	14041-10000-10293	1215 E WHOLESALE ST	90021	14	124-5A215  10	5164010005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM			PC Approved	04/18/2014 12:00:00 AM	ADDRESS	34.03668	-118.23791	Lighting to a cooler with occupancy sensor,  title 24. low rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63841	15041-20000-14559	12751 W MILLENNIUM Building A	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Title 24. Plan check for energy for energy only. Existing retail building. Adding new lighting including emergency. Total sqft. 2,646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63842	12041-20000-27548	5429 S MCCONNELL AVE	90066	11	102B157    46	4211009012	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	11/28/2012 12:00:00 AM	ADDRESS	33.97802	-118.41979	T-24 and emergency lighting for remodeled warehouse to showroom and office space.  The lighitng track is to be installed with integral current limites.  TENANT IMPROVEMENT FOR (N) SHOWROOM AND OFFICE SPACE IN EXISTING 2 STORY COMMERCIAL/WAREHOUSE BLDG.  SCOPE OF WORK INCLUDES (N) PARTITIONS, DOORS, CEILINGS, FINISHES AND MILLWORK.  EXTERIOR IMPROVEMENTS...(see additional comments)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63843	19041-10001-11268	4143 W DON MARIANO DR	90008	8	114B181   588	5026004008	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM			PC Approved	04/09/2019 12:00:00 AM	ADDRESS	34.00642	-118.34367	EXPEDITE PER APPLICANT REQUEST. ((PV1. NEW ROOF TOP SOLAR SYSTEM WITH BATTERY BACK UP. THE SYSTEM CONSIST OF 12 MODULES (Q-CELL 305) WITH A CENTRAL INVERTER (DELTA SALIVIA 3.8) AND A 13.5KWH TESLA POWERWALL. SYSTEM SIZE IS 3.6 KWac AND 3.66KWdc.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63844	14041-20000-13842	12554 W COLLINS ST PV1	91607	2	174B161   308	2341016008	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.17384	-118.40731	New roof mounted PV system with two centeral inverters.  Total system size 9.72KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63845	13041-10000-35680	1133 S LONGWOOD AVE	90019	10	132B185   865	5084023036	R2-1-O	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	05/23/2014 12:00:00 AM	ADDRESS	34.05474	-118.33956	PV1, Install 4.75 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (19) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63846	10041-10000-11210	3450 S WATT WAY	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	ADDRESS	34.02275	-118.28604	T-24 and emergency lighting plan check for remodeled portion of the Thornton School of Music.  Inspector, please verify listing of the Wenger Rooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63847	16041-20000-16674	11650 W NATIONAL BLVD 1-52	90064	11	120B153   948	4250008012	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.02295	-118.43777	PERMIT FEE $11.23 BY STATE SENATE BILL NO. 1222PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63848	15041-20001-28410	20732 W QUEDO DR	91364	3	169-5A109  80	2166046004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	34.15918	-118.58549	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 10kW with 44 modules and 2 inverters (5.0kW and 5.0kW)}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63849	16041-10000-37796	400-562 S PIER A ST BERTH 153-155	90744	15	024B205    48	7440019907	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	PIN	33.75773794	-118.27050253	Zero Permit fee due per California Senate Bill 1222.PC FOR ROOF MOUNTED PV.  FEED IN TARRIF (FIT) PROJECT . SYSTEM SIZE 1143KW.DC  913KW.AC SCOPE INCLUDES TOTAL OF 3362 MOUDULES AND 11 INVERTERS (83KVA).WITH NEW DEDICATED SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63850	17041-10000-18621	814 W 43RD PL	90037	15	114B197  1260	5019008030	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.0045	-118.28783	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 3.8 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63851	19041-10001-41257	10066 N VANALDEN AVE	91324	12	204B121   430	2729004004	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM			PC Approved	11/07/2019 12:00:00 AM	ADDRESS	34.2533	-118.54899	EXPEDITE FEEPV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 19.14 KWdc/ 16.82KWac. SCOPE OF WORK IS 58 MODULES (CANDIAN SOLAR CS1H-330MS) WITH MICROINVERTERS (IQ7-PLUS-72-2-US), LEADING TO A NEW 200A LOAD CENTER. MAIN PANEL UPGRADE TO BE SEPRATELLY PERMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63852	15041-20000-17541	629 S JUNE ST	90005	4	135B185   445	5507017007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.064	-118.33481	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SERVICE 600 AMPS. SYSTEM SIZE: 7KW. (26) LG LG305N MODULES WITH SOLAR EDGE P400 OPTOMIZERS. SOLARD EDGE SE 7600A US INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63853	18041-10000-35279	6411 N SEPULVEDA BLVD #1T	91411	6	180B145   763	2234016013	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.18729	-118.46647	TI IN AN EXISTING RETAIL STORE.  846 SQR FT. T-24 ENERGY ONLY.BULDING PERMIT: 18016-20000-26090	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63854	16041-10000-43663	21857 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	06/23/2017 12:00:00 AM		Issued	06/23/2017 12:00:00 AM	ADDRESS	34.1686	-118.60359	PC FOR POWER. SERVICE UPGRADE TO 2000 AMPS, 3 PHASE, 4 WIRE 120/208  IN EXISTING RETAIL BUILDING.  PROVIDE NEW SUBPANELS FOR TWO FUTURE TENANTS. B 16019-10000-04986	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63855	13041-10000-35693	7337 N CALDUS AVE	91406	6	186B129   989	2228003025	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/24/2014 12:00:00 AM	ADDRESS	34.20412	-118.5158	PV1, Install 3.18 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (12) modules: Suniva OpT265-60-4-1B0.***This building already has a solar array permit with # 13041-20000-26693 with system size 3.5 kw DC.***	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63856	12041-10000-26517	17260 W SUNBURST ST	91325	12	195B133    56	2690002012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.2344	-118.51077	INSTALL A 11.04KW PHOTOVOLTAIC SYSTE ON ROOF OF SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63857	18041-10000-38797	4030 S DEL REY AVE	90292	11	108B149  1265	4230004001	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.98993	-118.44631	PC FOR RETAIL TI FOR T24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS, EQUIPMENT AND PANELS. TOTAL AFFECTED AREA 8919 SQ.FTB# 18016-30000-25003	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63858	19041-10000-37389	5401 W HIGHLIGHT PL	90016	10	120B177   735	5047014900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Issued	09/18/2019 12:00:00 AM	ADDRESS	34.02341	-118.36456	Replacement of an existing defective Fire Alam Panel with a new one and adding 6 new FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63859	14041-10001-22884	5520 N KESTER AVE	91411	4	174B149  1026	2249028003	[Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.1708	-118.45723	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 2.25 ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(9) MODULES: KYOCERA KD250GX-LFB3(1) INVETER: SOLAREDGE SE3000A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63860	12041-20000-29515	4251 W 61ST ST	90043	8	105B181   694	4003009024	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2012 12:00:00 AM	01/02/2013 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	33.98451	-118.35051	single family solar micro inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63861	17041-20000-46125	11150 W GAULT ST	91605	2	183B173   146	2319022002	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM	12/22/2017 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.19927	-118.37408	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63862	16041-10000-10791	5645 N FARMDALE AVE 1-10	91601	2	174B169   670	2338028004	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Apartment			03/29/2016 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.17328	-118.38117	PC FOR POWER AND ENERGY. NEW 44-UNIT APARTMENT BUILDING:  3-story over basement parking  4 TYPE Very Low Income Affordable Dwelling Units. TOTAL AREA 33271 SQ FT.B# 14010-20000-04022	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63863	19041-10001-38712	1000 W TEMPLE ST	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.06171	-118.25046	Changes to an approved set of plans. Changes include relocating service equipment on the site floor plans.  No other changes has been made.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63864	13041-10000-27445	2010 N FIGUEROA ST	90065	1	141A219   108	5415001016	UC(CA)	East Los Angeles	Northeast Los Angeles	Greater Cypress Park, Greater Echo Park Elysian		1990.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/04/2013 12:00:00 AM	ADDRESS	34.08159	-118.22509	Remove HID light fixtures and install new fluorescent fixtures in an auto repair shop.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63865	16041-10001-34573	18716 W PRAIRIE ST	91324	12	198B121   495	2763015014	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM			PC Approved	02/23/2017 12:00:00 AM	ADDRESS	34.23901	-118.5411	02/23/17Changes to an approved set of plans. Changes include changing out AC module from Sunpower SPR-X21-345-C-AC to Sunpower SPR-E20-327-C-AC. Number of modules remain the same. Note: Permit is paid under PCIS#16041-10000-34573	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63866	14041-10000-05923	1000 W ELYSIAN PARK AVE LEVEL 5	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	Dodger Stadium remodel of (2) luxury suites into (1) large suite.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63867	14041-20000-32113	12001 W IREDELL ST	91604	2	159B165    93	2376021006	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Expired	02/02/2017 12:00:00 AM	ADDRESS	34.13093	-118.39411	PV1 INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN ELECTRIC PANEL. 9.5 KW DC/8KW AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63868	11041-20000-05378	9201 N OAKDALE AVE 2nd. Floor	91311	12	198B113   214	2761001084	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	07/14/2011 12:00:00 AM	ADDRESS	34.2381	-118.56706	T.I. to existing building.  Install general/emergency lighting in classroom and office.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63869	15041-20001-02628	1989 N LINDA FLORA DR	90077	5	150B145   186	4377005004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2015 12:00:00 AM			PC Approved	02/03/2015 12:00:00 AM	ADDRESS	34.10649	-118.46632	Fee for expedite only.*****Ground mounted PV system with total system size 15KW.Note: Resubmit due to lost plans	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63870	19041-10000-29607	510 S BROADWAY ST level 4	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	03/11/2020 12:00:00 AM		Issued	03/11/2020 12:00:00 AM	PIN	34.04751876	-118.25072319	FULL PC FOR TENANT IMPROVEMENT OF FLOORS 2,4, AND 5 IN AN EXISING BLDG. THIS IS THE 4TH FLOOR OF THE SERIES. SERVICE SIZE IS 600A, 120/240,3PH,4W AND 400A,120/240,1PH, 3W. AREA OF SCOPE 6,265SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63871	13041-10000-03764	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	13041-10000-03764T24 for office spaces for the dodger stadium. Lighting and receptacles only. 920 sqrft.PERMIT WILL BE OBTAINED AT PLAN CHECK COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63872	14041-10001-07220	7301 N MEDICAL CENTER DR #105	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	34.20262	-118.62963	Customer has lost the original approved plan, and request a brand new same set with new  approved stamp by presenting a copy of original set plan.(14041-20000-07220)  (((New X-Ray room for medical building.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63873	11041-20000-04944	9036 N RESEDA BLVD	91324	12	198B125   273	2769001024	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			03/14/2011 12:00:00 AM			Corrections Issued	03/14/2011 12:00:00 AM	ADDRESS	34.23507	-118.53587	PLAN CHECK T24 ENERGY FOR RESTROOMS IN (E) BANK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63874	19041-10000-16954	401 E 3RD ST	90013	14	129A213   189	5161020010	R5-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.04737	-118.24223	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63875	17041-20000-28095	22935 W OXNARD ST	91367	3	177B097   461	2039016013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.17929	-118.62665	"""0$ permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (48) modules, (48) micro-inverters, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63876	19041-10000-48065	14424 W PLUMMER ST	91402	6	198B149    82	2644027078	RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.2425	-118.44724	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63877	16041-10000-27747	1124 S SAN JULIAN ST	90015	14	124-5A211 188	5145025002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.03521	-118.25351	Plan check for T-24 only.  TI for change of use from Produce market to restaurant and wine market. Install new lightings, receptacles, and a panel with additional load < 400A.  Total affected area: 4,825 sq.ft. (B# 16016-10000-04454)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63878	17041-10000-28606	12229 W PICO BLVD	90064	11	120B149    46	4259029009	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM			PC Info Complete	08/15/2017 12:00:00 AM	ADDRESS	34.02871	-118.45202	COFFEE SHOP ON FIRST FLOOR. PC FOR T24 ENERGY ONLY. TI. Note: Permit is paid under express permit PCIS#17041-30000-24773	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63879	14041-10000-22027	135 S BARRINGTON AVE	90049	11	135B145   620	4401007018	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			Corrections Issued	08/14/2014 12:00:00 AM	ADDRESS	34.06441	-118.46926	TI, TOTAL AREA 358 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63880	14041-10000-31506	200 WORLD WAY Space-281	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	06/04/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Full plan check for first time tenant, Starbucks Coffe Company, at Terminal-2 level-1 space281. per F.Y	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63881	18041-20002-13406	13415 W ERWIN ST	91401	2	177B157   372	2330005023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.18315	-118.42522	Plan check for backup battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63882	17041-10001-16935	1808 N VERMONT AVE	90027	4	150B197  1119	5590020001	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.10392	-118.29162	T-24, PC FOR ENERGY ONLY. TI FOR EXISTING STORE. SCOPE INCLUDES NEW LIGHTS, NEW RECEPTACLES, AND ONE NEW 200A PANEL. TOTAL AFFECTED AREA IS 847 SQ. FT.  COMPLY WITH DEPT. ORDER DATED 4/18/17. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE.NOTE: MOST OF THE FEES FOR PERMIT WERE PULLED UNDER PCIS#17041-70000-16935	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63883	14041-20000-07975	5655 N KATHERINE AVE	91401	4	174B153   563	2245022008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.17369	-118.44339	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63884	16041-10001-44563	1828 E CESAR E CHAVEZ AVE 600	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			PC Approved	10/02/2018 12:00:00 AM	ADDRESS	34.05014	-118.21571	PC FOR CHANGES TO APPROVED SET UNDER DELTA 3 ONLY. SCOPE INCLUDES NEW INVERTER FOR EM. LIGHTS TO COMPLY WITH U.L. 924.THIS IS PLAN CHECK ONLY! PERMIT PAID UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63885	13041-10000-09977	7270 W MELROSE AVE	90036	5	141B181   622	5525013004	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM			PC Approved	04/17/2013 12:00:00 AM	PIN	34.0832604	-118.34817541	"13041-10000-09977.CHANGE OF USE FROM  RETAIL ( 19' X 78'-3"") TO  NAIL SALON PLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63886	12041-20000-09659	2320 E OLYMPIC BLVD	90021	14	121-5A217 381	5167010008	M3-1-S	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Issued	11/05/2012 12:00:00 AM	ADDRESS	34.02561	-118.23133	Relocation of 600A service. Plan check for power and energy. 12610 conditioned sqft. Single-story warehouse (no generator).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63887	16041-10000-45237	10250 W SANTA MONICA BLVD # 2820	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""CATIMINI"" Ste. 2820.  Install new panels and its circuits, lights and receptacles. Total effected area: 898 sq.ft. ."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63888	19041-20000-42392	13412 W SYLVAN ST	91401	2	177B157   157	2330006006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.18475	-118.42519	PV1. INSTALL 11.22 KW DC PV SYSTEM WITH (34) MODULES/MICROINVERTERS (ENPHASE IQ7X-96)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63889	13041-20001-23809	2737 N BEVERLY GLEN BLVD	90077	5	156B149    66	4379005028	RE15-1-H-RPD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	34.1209	-118.44648	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6 KW AC USING 18 MODULES. 3 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63890	13041-20000-01614	670 S KELTON AVE 1-48	90024	5	135B149   492	4363014010	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.03	Electrical	Electrical	Apartment			01/22/2013 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.06486	-118.45263	Plan check for power and energy. New 48unit apartment. Equipment counts per customer, please verify fees during final fee period. FIRE ALARM VARIANCE HAS BEEN FILED. METHANE BUFFER ZONE.Variance to extend plan check time filed 07/01/2014.2 plan check time extensions have been filed 7/30/15. absolute last date to obtain an electrical permit is on 1/22/16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63891	12041-10001-13237	603 S SPRING ST	90014	14	129A211   220	5144002017	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Approved	09/14/2012 12:00:00 AM	ADDRESS	34.04585	-118.25136	REVISION TO APPROVED NEW FIXTURES ADDED AND ADDRESS CHANGE. PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR STARBUCK COFFEE SHOP ON THE GROUND FLOOR OF AN HIGH RISE BUILDING. NO EMERGERNCY GENERATOR IN BUILDING. USING 120 BATTERY BACK UP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63892	17041-10001-22841	13286 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	33.97878	-118.43604	CHANGES TO AN APPROVED SET OF PLANS. SCOPE INCLUDES EXPANDING DENTAL OFFICE WITH NEW POWER AND ENERGY. REVISING FLOOR PLANS, RELOCATING PANELBOARDS, AND REVISING TITLE 24 CALCULATIONS. NEW TOTAL AFFECTED AREA IS 2182 SQ. FT.  B#17016-20001-18456	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63893	15041-10000-10295	10647 W ASHTON AVE	90024	5	132B153   219	4326001023	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			04/07/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.06015	-118.43457	INSTALL NEW FIRE ALARM FOR A 14 UNITS RESIDENTIAL APARTMENT WITH  60 FA DEVICES AND 2 CONTROL PANEL AND ONE FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63894	16041-10000-16004	12841 N HERRICK AVE	91342	7	222B149   829	2506028014	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.30308	-118.45053	PV1. ROOF MOUNTED SYSTEM CONNECTED TO THE MAIN PANNEL. 28 MODULES (CANADIAN SOLAR MODEL - CS6K-260P). 6KVA INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63895	14041-20000-35405	6733 1/2 N FALLBROOK AVE	91307	12	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	PIN	34.19178197	-118.62467253	Plan check for energy only. TI for existing retail space - photo studio. New lighting (incl. emergency) and receptacles. 2,216sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63896	16041-10000-28803	4024 N RADFORD AVE #ADMIN-BUILD.	91604	2	165B169   716	2368005011	[Q]M2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.14441	-118.39252	Install New Optional standby Diesel Generator with its ATS.  2400 V, 1200A ATS, and 1000kW Generator at 2400 V.  This generator only supplies the Admin. Building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63897	11041-20000-08695	10850 W PICO BLVD #M2	90064	5	126B157  1663	4256001025	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM	06/17/2011 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.03983	-118.42857	Install new panels and branch circuits.  Plan check for power only.Note:  Lighting plan check approved under 11041-20000-07866	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63898	18041-20000-30782	2250 N EDGEMONT ST	90027	4	153B197   625	5588008005	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.11159	-118.29795	Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (2) Tesla PowerWall to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63899	16041-10000-25271	17352 W SUNSET BLVD BUILDING-CD	90272	11	126B117   516	4415018016	C2-1VL, [Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	05/06/2017 12:00:00 AM	ADDRESS	34.03939	-118.55367	** Plan 1 of 2:PLAN CHECK FOR POWER AND ENERGY ON (E) EXISTING CONDOMINIUM BUILDING. INSTALL NEW MECHANICAL EQUIPMENTS. VOLTAGE RATING IS 4800V, NEWLY CONNECTED LOAD > 400A. TOTAL AFFECTED AREA: 4,732 SQ.FT*This plan is 1 of 2. One Service feeding both buildings AB, and CD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63900	12041-10000-07761	1726 S WESTERN AVE	90006	10	126B193   551	5074014043	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	34.04197	-118.30883	Change of use from Restaurant to Vetenary office.  Load is 143 amps and the occupancy load is 16 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63901	12041-20000-08335	6450 N FARRALONE AVE	91303	3	180B101   687	2139024027	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2012 12:00:00 AM	05/03/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	34.18782	-118.61138	pv system single family 5.3 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63902	13041-10000-09453	1916 S GAFFEY ST	90731	15	012B197  1076	7462017023	R2-1XL	Harbor	San Pedro	Coastal San Pedro		2972.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	33.72646	-118.29224	PV1 for 2 story house.  {central inverter: Sunny Boy 7000-US} {30 modules: TSM-245 PC/PA05}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63903	17041-20000-15684	19854 W BARBERRY LANE	91356	3	162B113    98	2180021005	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/24/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.13977	-118.5667	Plan check for solar pv system, roof-mounted on SFD.6.6kW ungrounded system, (26) pv modules.Interconnecting with an existing 7.5kW pv system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63904	14041-10001-12648	5844 N MURIETTA AVE	91401	2	174B153   120	2246015007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.17699	-118.4387	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL  5.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER AND WITH OPTIMIZERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63905	13041-20000-31634	7230 N MEDICAL CENTER DR #500A	91307	12	183B097    18	2021014042	QCR-1, QP-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.20143	-118.62922	"New UPS, new panels, relocate panels, change to lighting in an existing Medical ""Pain Management"" Suite.  NOT STATE LICENSED PER THE APPLICANT, NOT CHECKED FOR OSHPD3."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63906	10041-20000-24968	13652 W CANTARA ST South 1-Parking	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.21973	-118.43084	Plan check power for installaing new branch ckts and replacing existing 75 kw generator with new 150 kw optional standby generator for Kaiser south 1 parking structure.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63907	14041-20001-02706	22032 W GRESHAM ST	91304	12	195B101   232	2010008001	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.23006	-118.60702	((EXPEDITE FEEES)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 9.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63908	18041-20001-17412	4770 W CROMWELL AVE	90027	4	153B197   536	5588016017	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM			PC in Progress	05/19/2018 12:00:00 AM	ADDRESS	34.11244	-118.29351	Expedite per applicant requestPlan check for battery PV roof mounted system with battery back up system. System size: 7.6kWac with 30 modules and 1 inverter(7.6kWac) connected to battery LG9.8kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63909	10041-10002-01159	15825 W ROXFORD ST	91342	7	222B141    96	2604002037	M1-1, P-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	10/25/2010 12:00:00 AM	ADDRESS	34.30457	-118.47839	Revision to approved set changing plan as built. change was new feeder size and breaker for generator and feeder after ATS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63910	16041-20000-19515	400 N KENMORE AVE	90004	13	138B197    73	5520016010	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.07786	-118.29679	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (15) modules with power optimizers. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63911	19041-10001-17668	2000 W MIRAMAR ST 1-22	90057	13	135A205   224	5154020030	R4-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Apartment			05/10/2019 12:00:00 AM			PC Approved	12/26/2019 12:00:00 AM	ADDRESS	34.06323	-118.27067	EXPEDITE FEE FOR: NEW 60.2KW ROOF MOUNTED PV SYSTEM WITH 165 PV PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63912	17041-20000-05602	16062 W SUNBURST ST	91343	12	195B141    87	2672004022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.23444	-118.4827	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.6.6kW ungrounded system. (30) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63913	13041-10000-22347	10176 W OLIVIA TER PV1	91352	2	192B177   769	2403009048	RE20-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.22018	-118.35297	PV1- ROOF MOUNTED SOLAR, (25) MODULES. (6.13 KW) Solar device(s).MODULE:YINGLY YL245P-29B 245WINVERTERS: POWER-ONE-PVI-5000-OUTD-US(240V)PERMIT # : 13041-10000-20114 & 13041-10000-17734	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63914	10041-10000-16731	2049 S CENTURY PARK EAST 2ND FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	01/14/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN AN EXISTING CORIDOR ON THE 2ND FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63915	18041-10001-07705	1601 S VICTORIA AVE	90019	10	126B185   134	5071004001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.04485	-118.32987	Supplemental PC for PV expedite.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63916	14041-20000-07547	3003 W PEAK PL	90065	13	154-5A215 618		RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.1188	-118.23814	PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 1.3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63917	13041-10000-32028	3969 N GOODLAND AVE	91604	2	162B161   292	2384018028	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	06/09/2014 12:00:00 AM	ADDRESS	34.14235	-118.4107	PV1.  Install 11 kW DC roof-mounted PV system, interconnect with main service panel.  44 modules: Renesola JC250M-24/BB.  2 transformerless inverters: SolarEdge SE5000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63918	18041-10000-33305	3400 S SAWTELLE BLVD	90066	11	117B157    80	4249001012	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.02006	-118.42631	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63919	13041-20000-23504	7480 S MCCONNELL AVE	90045	11	102B161   146	4110029027	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	33.97311	-118.41306	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. USING 22 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63920	15041-10000-28760	1200 W 7TH ST #410	90017	1	130-5A207 184	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.05136	-118.26616	Energy plan check for an office T. I located in the 4th floor of a high rise building. Scope includes new lighting and receptacles with existing circuits. Total area is 15742-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63921	18041-20000-44396	4545 N ALONZO AVE	91316	5	168B129   721	2182021020	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.15305	-118.52149	PV1.  Install 4.5 kW roof mounted grid tied PV system.  (15) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63922	15041-20000-36207	700 WORLD WAY SPACE 7C	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	PROPOSED TENANT IMPROVEMENT FOR  CHANGE OF USE FROM  FOOD & BEVERAGE CONSSECION TO RETAIL PREPACKAGE FOOD.PC for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63923	11041-10000-19582	19304 W SATICOY ST	91335	3	186B117   239	2116015056	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1316.00, 1317.00	Electrical	Electrical	Commercial			09/14/2011 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.20822	-118.55412	TI IN AN EXISTING STORE OF A GAS STATION.   PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63924	18041-20000-45870	5700 W COLISEUM ST	90016	10	117B173   197	5029013021	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.01896	-118.36987	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 15 MODULES WITH MICRO  INVERTERS. TOTAL SYSTEM SIZE 3.75 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63925	11041-10000-15249	9724 W OAKMORE ROAD	90035	5	129B165   777	4307017012	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2011 12:00:00 AM			Reviewed by Supervisor	02/24/2012 12:00:00 AM	ADDRESS	34.04767	-118.39957	New 6.67 KW roofmounted PV system for a single family residence using 2 inverters.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63926	15041-10000-33450	5422 W CARLIN ST	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			Reviewed by Supervisor	10/20/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	PV1, INSTALL NEW 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63927	18041-10000-16540	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	34.05715	-118.41482	PC FOR POWER AND ENERGY FOR AN EXISTING 16 STORY CENTURY PLAZA HOTEL INCLUDING 4 LEVEL PARKING BELOW GRADE AND 6 LEVELS FOR FUTURE CONDOS. THERE ARE 394 GUEST ROOMS & 67 DWELLING UNITS. SCOPE INCLUDES ADDING A NEW 1200A 4160V 3 PHASE SERVICE/SWITCHGEAR, TWO NEW 150HP FIRE PUMPS, AND ONE 2187.5KVA 480/277V GENERATOR, NEW MOTORS, AND NEW LIGHTS. TOTAL AFFECTED AREA 694,348 SQ. FT.  B#14014-10000-05098, 10001, 10002SOME PC FEES ARE COVERED UNDER PCIS APP. # 17041-10000-35150	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63928	11041-10000-16265	707 W WILSHIRE BLVD # 3750	90017	9	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.04893	-118.2572	tenant improvements in officesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63929	14041-20000-07589	550 S HOPE ST SUITE 100	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.04989	-118.25574	pc for t24 energy only. new lighting in existing tenant. suite 100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63930	18041-10001-01031	3700 W WILSHIRE BLVD	90010	10	132B193    66	5093006019	C4-2, CR-2, P-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	34.06147	-118.30682	Change to approved set by updating the feeder size per field installation.(((**Zero permit fee per AB-1414/ SB-1222**Install New PV system on a commercial building, 133.2kW AC system. Scope includes (4) inverters SE33.3KUS, (456)modules with (228)optimizers, (1) 200A combiner panel. PV system will connect to (E) 4000A, 480/277V service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63931	14041-20000-02402	8532 N VAN NUYS BLVD	91402	6	192B149   107	2638001043	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.2257	-118.44884	T24 FOR EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63932	17041-20000-13782	700 S FLOWER ST 21st Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is the 21st floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,148 sq. ft.Note: Building application has been generated under 17016-70000-09261	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63933	12041-10000-08072	10400 W WILSHIRE BLVD 1ST FL	90024	5	135B157   182	4327001012	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			04/09/2012 12:00:00 AM			PC Info Complete	06/18/2012 12:00:00 AM	ADDRESS	34.0666	-118.42904	ALTERATIONS IN OFFICES AND CORRIDOR AND LOBBY OF THE OFFICES AT A SCHOOLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63934	11041-20000-23041	2117 W CLINTON ST	90026	13	138A207    30	5402038034	R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Apartment			10/27/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.07398	-118.26634	NEW 600 AMP SERVICE TO REPLACE AN EXISTING SERVICE.  PLAN CHECK IS FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63935	19041-10001-19138	10250 W SANTA MONICA BLVD AMC-#2000	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PLAN CHECK ONLY. DELTA 4 CHANGES TO AN APPROVED SET. CHANGES INCLUDE MODIFICATIONS TO LIGHTING FIXTURES, EMERGENCY PHOTOMETRICS, AND TITLE 24  ---------------------------------TI IN EXISTING ""AMC"" AUDITORIUM IN SUITE #2000. NEW LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA IS 5552 SQ. FT. BLDG#19016-10000-15087"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63936	12041-10000-17320	12201 W SHERMAN WAY	91605	2	183B165    23	2307021900	PF-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.20131	-118.39919	Plan check for power and energy. Heavy duty truck repair shop (trash trucks). 3188 sq ft (1959 unconditioned). Unclassified area due to mechnical ventilation. Methane zone.1st extension filed on 12/18/2013: date was extended from 01/25/2014 to 07/25/2014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63937	12041-10001-28750	"3740 W EVANS ST BLDG ""B"""	90027	4	150B201   845	5433023040	R2-1XL	Central	Hollywood	Greater Griffith Park	YES	1952.01	Electrical	Electrical	Apartment			08/12/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Issued	09/23/2013 12:00:00 AM	ADDRESS	34.10626	-118.27387	"ALTERATION OF FOUR BUILDINGS ""A"", ""B"", ""C"" & ""D"". SERVICE UPGRADE,  ADDITION OF NEW METERS AND DISTRIBUTION PANELS, ADDITIONAL CIRCUITS TO UNITS, NEW AC UNITS,  NEW UTILITY TRANSFORMER ON SITE. THIS PERMIT IS FOR BUILDING ""B"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63938	13041-10000-23777	23952 W NOMAR ST	91367	3	174B089    40	2045020011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.17681	-118.64929	PV1 10.78KWdc 240V XFMR INV. 2STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 10-1UNI][( 44) MOD: TRINA {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63939	10041-10000-21673	7857 W MANCHESTER AVE	90293	11	096B153   463	4115024014	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Apartment			10/29/2010 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	06/11/2012 12:00:00 AM	ADDRESS	33.95994	-118.43455	New 32 unit condominium building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63940	19041-10001-14944	17263 W VANOWEN ST	91406	6	183B133   936	2230001012	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			Reviewed by Supervisor	05/09/2019 12:00:00 AM	ADDRESS	34.19403	-118.5093	"""Expedite per applicant request""PV2 roof mounter system, size is 39.6KWdc/38.5KWac. Scope of work includes 120 modules (Candian Solar CS6U-330P), 5 inverters (Sunny Boy SB-7.7 -1SP-US-40) , 200 A combiner panel."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63941	14041-20000-13336	12659 N DORINA PL	91344	12	219B133    32	2602019008	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Expired	07/12/2016 12:00:00 AM	ADDRESS	34.30095	-118.50533	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.43KW INTERCONNECTED WITH MAIN PANEL (2) TRANDFORMERLESS INVERTERS SOLAREDGE SE3800A(37) TRINA SOLAR MODULES TSM-PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63942	14041-20000-03369	12344 N EDGECLIFF AVE	91342	7	219B145   637	2611037033	RA-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.2945	-118.46346	Roof mounted PV system with 6KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63943	16041-10001-32532	8465 N CRANFORD AVE	91352	6	192B165   270	2634040020	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2016 12:00:00 AM			PC Approved	10/04/2016 12:00:00 AM	ADDRESS	34.22454	-118.4004	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SSYTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.2KWac.(54)MODULES-KYOCERA #KU2656ZPA(2)INVERTERS-DELTA #SOLIVIA 6.6 TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63944	19041-10000-42186	1230 N SAN FERNANDO ROAD	90065	1	145-5A217  20	5454036030	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.09479	-118.23062	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR/OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63945	16041-20000-20696	555 S FLOWER ST 3rd,4th-5th Floor	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.05048	-118.25755	Plan check Title 24 only in existing  space office T.I. on 3rd, 4th and 5th Floor.  Total area: 4,646 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63946	14041-10000-02545	2126 S BEVERLY DR	90034	5	126B165   272	4309017002	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.04351	-118.39498	PV1 6.45KWAC. 240V. microinverter. NONstd. 2story. Roofmount. [(30) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(30)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63947	14041-20000-33802	10948 N HILLHAVEN AVE	91042	7	210B197   416	2553018013	RE9-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.26839	-118.28803	Roof mounted PV system with total system size 7.2KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63948	17041-10000-29263	120 N ROBERTSON BLVD	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.07585	-118.38356	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW OUTDOOR LIGHTS FOR AN EXISTING COURT-YARD AND NEW LIGHTS FOR FACADE LIGHTING. TOTAL AFFECTED AREA IS 8834 SQ. FT. B#16016-10000-30211	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63949	14041-20001-05348	10100 W VENICE BLVD SUITE 1000	90232	5	120B165  1282	4208002019	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM			PC Approved	03/21/2014 12:00:00 AM	ADDRESS	34.0221	-118.40033	((3/21/2014- Changes made to approved T24 plans. Changed fixture A and removed battery pack))PC FOR T24 ENERGY ONLY. EXISTING OFFICES NEW LIGHTING. TOTAL AREA 1350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63950	17041-10000-05785	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.23342	-118.3809	FULL PC FOR POWER AND ENERGY FOR WASTE MANAGEMENT FACILITY. SCOPE INCLUDES A NEW 600A 480/277V 3 PHASE 4 WIRE DISTRIBUION BOARD, NEW PANELS, NEW PUMPS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 6215 SQ. FT.  B#16014-10000-05196	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63951	12041-10000-13517	5700 W PICO BLVD	90019	10	129B177   592	5069010001	C4-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			06/11/2012 12:00:00 AM			PC Approved	06/28/2012 12:00:00 AM	ADDRESS	34.05051	-118.36273	Plan check for energy and emergency lighting. Two story retail space. Occupancy is less than 100. 2876 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63952	15041-10000-43055	101 N LA BREA AVE	90036	5	138B181   828	5513002001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.07377	-118.34423	Full plan check for a new (1) story construction with a parking lot located in the top level. Scope includes (1) new 800-Amp service and a house panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63953	12041-20000-24310	9080 W PICO BLVD	90035	5	132B169   884	4305001020	C4-1VL-O, R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM			PC Approved	10/15/2012 12:00:00 AM	ADDRESS	34.05508	-118.38965	PLAN CHECK FOR ENERGY. 1002 SF INTERIOR REMODEL ONLY FOR 4560SF EXISTING CHASE BANK - CONSTRUCTING TWO NEW PRIVATE OFFICES. OPEN OFFICE CUBICLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63954	14041-20000-23470	8736 N HANNA AVE	91304	12	195B105   178	2010009006	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.2295	-118.60411	PV1 SFD. TOTAL SYSTEM SIZE 8.8KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. SYSTEM USES 2 INVERTERS. 39 MODULES. POWER OPTIMIZERSFIRE DECLARATION SIGNED PER REQUIREMENT NO. 96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63955	18041-20000-26877	14860 W ROSCOE BLVD	91402	6	192B149   421	2210003074	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Issued	07/18/2018 12:00:00 AM	ADDRESS	34.22131	-118.4572	Elevator emergency operation system addition in (E) commercial medical office building.  Stand-alone system for elevator recall and shunt-trip operation not connected to (E) building fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63956	16041-10000-38684	9165 N GLENOAKS BLVD	91352	6	198B173   145	2408033038	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.23566	-118.37289	FINAL FEES = $0.00 DUE TO SENATE BILL 1222PV2 INSTALLATION OF NEW 60KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMMERCIAL BUILDING. (150) MODULES: SUNPOWER SPR-X20-327-COM(2) INVERTERS: SMA AMERICA STP 30000TL-US-10	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63957	16041-10000-04711	6660 W SUNSET BLVD #  Q	90028	13	147A185    84	5547023028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/10/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.09781	-118.33562	T-24, PC FOR ENERGY ONLY. CHANGE OF USE TO A CAFE/JUICE SHOP FROM A RETAIL AT EXISTING SHOPPING CENTER.  SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND TWO NEW PANELS. TOTAL AFFECTED AREA IS 1064 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63958	18041-10001-41287	624 S GRAND AVE 1610&1500	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Corrections Issued	05/21/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	Change to approved set by modifying the disconnect operation and temperature regulation update. all change under delta-1 only.See comment for detail.(((PLANCHECK FOR POWER AND ENERGY FOR DATA CENTER. INSTALLING MEDIUM VOLTAGE SWITGEAR AND LIGHTING IN SUITE 1610 AND SUITE 1500. NO CONNECTEDLOAD UNDER THIS SOW, LOAD ON DISTRIBUTION PANEL AND FLOOR PLANS ARE FOR REFERENCE ONLY (FOR FUTURE INSTALLATION). TOTAL AREA: 13,745 SQ.FT)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63959	19041-30000-23198	4020 S BUCKINGHAM ROAD	90008	10	117B181   723	5032004021	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			06/18/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	03/31/2021 12:00:00 AM	ADDRESS	34.01383	-118.34223	pc (energy and power) for a new landscaping . area of scope is 9,790SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63960	16041-20000-31729	400 S HOPE ST 2nd Floor	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for Title 24 only. Project site is the 2nd floor of an existing commercial building. Project scope is a tenant improvement to existing lockers and showers. Total lighting area = 1,395 sq. ft.Note: Building application has been generated under 16016-10000-04812	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63961	14041-10000-26429	8910 N LANKERSHIM BLVD	91352	6	195B169   231	2631016033	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.23109	-118.38757	Title 24 plan check only.  Total area = 1560 sq. ft.  Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63962	15041-20002-01389	1045 W 46TH ST	90037	9	111B197   371	5017031013	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	34.00176	-118.29327	Changes to approved set.  New system is 1 branch circuit with 16 microinverters.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.25 KW. (29) HYUNDAI HISM250(29) ENPHASE ENERGY M215	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63963	14041-20000-28052	6138 N ENSIGN AVE	91606	2	177B173   563	2336036026	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.18232	-118.37115	PV1.  Install 5.355 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63964	14041-10000-12696	2650 E OLYMPIC BLVD	90023	14	120A219    13	5169010006	C2-1, M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	10/31/2014 12:00:00 AM	ADDRESS	34.02485	-118.22188	TI FOR LIGHTING AND CEILING TILES FOR EXISTING COMMERCIAL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63965	12041-20000-14353	3551 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM			PC Approved	06/20/2012 12:00:00 AM	ADDRESS	34.02066	-118.28531	T.I. to USC Administrator building - 1st floor (lobby and hallway) and 2nd floor (board room, conference room, restroom).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63966	16041-10000-18758	3939 S CRENSHAW BLVD # D	90008	10	117B185  1242	5032002060	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.01358	-118.33646	ENERGY PLAN CHECK FOR A SUBWAY SANDWICH SHOP WITHIN A EXISTING TENANT SPACE; TOTAL AREA IS 1800 SQ FT. PROJECT IS UNDER DESIGN-BUILD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63967	14041-10002-14508	1825 N BRONSON AVE	90028	13	150A191   280	5586027006	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			07/21/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.10425	-118.31823	(148) NEW DEVICES.  ONE NEW PANEL / PERMIT WAS PULLED UNDER 14041-10000-14508. PLAN CHECK ONLy (((((((((((((((((((((    addition of 80 new devises.))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63968	10041-10000-00637	777 E 10TH ST # 117	90021	9	124-5A211 244	5132002028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			01/13/2010 12:00:00 AM	02/03/2010 12:00:00 AM		Permit Finaled	03/09/2010 12:00:00 AM	ADDRESS	34.03437	-118.24974	Plan check for  power and energy for first time tenant retail.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63969	13041-10001-34374	12936 W WENTWORTH ST	91331	6	195B161   138	2628010020	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.23466	-118.41433	Expedited RSES plan check per applicant request.{{{PV1, install 2 kw DC roof-mounted solar array for a 2-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. (8) modules: Trina Solar TSM-250PA05.18.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63970	15041-10001-39736	5803 N IRVINE AVE	91601	2	174B169   282	2339011053	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	34.17598	-118.38567	PV1. PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (35)MODULES-YL255P-29B(1)INVERTER-SOLAREDGE 7600-US NOTE: PERMIT PULLED UNDER PCIS#15041-10000-39736(((Install a roof mounted photovoltaic system to existing single family dwelling (9.69       KW) Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63971	13041-20000-35552	8900 N DE SOTO AVE BLDG 101	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	FOR BLDG 101 ONLY,pc for power and energy. new equipment >600A. transformer and minor distribution. pc for new lighitng. 3034 sq ft seperate from power plan check. inpector to field verify new lighting loads. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63972	11041-10000-18533	14401 W VENTURA BLVD	91423	4	166-5A151 296	2265014017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			PC Approved	09/01/2011 12:00:00 AM	ADDRESS	34.15069	-118.44613	TI TO AN EXISTING AUTO SHOP OFFICE AREA.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63973	16041-20000-21953	7942 N KEER DR	91335	12	189B125  1025	2102015098	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21532	-118.53476	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63974	13041-20002-10688	20520 W NORDHOFF ST	91306	3	195B109    72	2780001050	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	PIN	34.23141269	-118.58091638	Supplemental description: Change to wire size and run lengths.Original work description: New fire alarm system for 2-story commercial building.  78 devices, 1 new panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63975	17041-10000-34889	14944 W CHATSWORTH DR	91345	7	207B149   200	2615023007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.26657	-118.45832	ROOF-MOUNTED 9.075KW PHOTOVOLTAIC SYSTEM-2 SRTINGS , 7.6kw INVERTER AND 33 MODULES	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63976	17041-10000-15693	900 W WILSHIRE BLVD	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	PC FOR DC SYSTEM TO POWER OUTLINE LIGHTING. CLASSIFIED AS ORNAMENTAL PER T24 STANDARDS. 3 DC SYSTEM SUBSTATIONS AND DISTRIBUTION TO LIGHTING OUTLETS. 48V DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63977	15041-10002-44014	12733 N DARYL AVE	91344	12	222B129   309	2608001025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Expired	07/11/2018 12:00:00 AM	ADDRESS	34.3019	-118.51464	Changes to approved set: adding 2 more modules and replace modules' model# to total (68) CS6P-265P<<PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1, INSTALL 11550 WDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(66) MODULES:REC SOLR REC275TP(2) INVERTER: SOLAREDGE TECHNOLOGY SE 7600A-US 240V>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
63978	18041-20000-46378	346 N LAUREL AVE pv1	90048	5	138B177   180	5527034005	R1V3	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.07744	-118.36464	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63979	16041-10000-03711	13630 W VAN NUYS BLVD 106-107	91331	7	207B157  1196	2646006025	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Info Complete	02/02/2016 12:00:00 AM	ADDRESS	34.2603	-118.42973	T-24, PC FOR ENERGY ONLY. FIRE DAMAGE REPAIR TO AN EXISTING COMMERCIAL BUILDING (OFFICE/RESTROOM SPACE). SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES FOR UNITS 106 & 107. TOTAL AFFECTED AREA IS 1970 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63980	19041-10000-11765	5711 N SEPULVEDA BLVD	91411	4	174B145   884	2260010017	CM-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.17435	-118.4665	INSTALL NEW FIRE ALARM WITH 349 DEVICES AND 1 PANEL AT TARGET STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63981	14041-20000-05543	16501 W VENTURA BLVD SUITE 448	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	ADDRESS	34.1578	-118.49275	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK IN SUITE 448 IN COPY ROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63982	14041-10000-02582	1647 W TEMPLE ST 1-49	90026	13	136-5A207 139	5159023011	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			01/29/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	06/26/2015 12:00:00 AM	ADDRESS	34.06861	-118.26247	PLANCHECK FOR POWER AND ENERGY FOR NEW 49 UNIT APARTMENT BUILDING OVER PARKING GARAGE WITH SWIMMING POOL. 3 STORIES. METHANE ZONE. (((((((((((((ADDITION OF 3 PANELS, 6 EQUIPMENTS, AND 98 CKT UNDER SUBMITTAL 2. APPLICANT BROUGH THE REVISED PLAN AFTER PLAN WAS ASSIGNED.))))))))))BUILDING P# 13010-10000-01973	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63983	19041-10000-02168	11328 S VERMONT AVE	90044	8	087A199   197	6075009022	[Q]C2-1XL	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.93168	-118.29135	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63984	14041-20001-25055	5469 N OAKDALE AVE	91364	3	174B113   509	2164003001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	09/26/2014 12:00:00 AM	ADDRESS	34.17012	-118.56599	Expedited plan check per applicant request.  PV1.  Install 15.04 kW roof-mounted, utility-interactive PV system.  SolarEdge inverters SE5000 and SE6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63985	17041-10000-31224	21900 W BURBANK BLVD SUITE 300	91367	3	174B105    46	2146007120	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.17189	-118.60404	3RD FLOOR OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63986	14041-20000-23152	18241 W DONMETZ ST	91326	12	210B125   158	2715032026	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.27409	-118.53104	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.PV1 SFD. TOTAL SYSTEM SIZE 12KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
63987	14041-10001-24955	1333 W 42ND ST	90037	9	114B197   713	5020004018	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	ADDRESS	34.00743	-118.29924	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: POWER-ONE AURORA PV1-4.2-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63988	12041-10000-20054	8540 W VENICE BLVD	90034	10	123B173   520	5065007033	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.03418	-118.37919	T.I. to an existing office Space.  Load is 100 Amps, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit Fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63989	19041-20000-40053	355 S GRAND AVE 2nd Flr	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.05191	-118.2525	Tenant Improvement in existing office space new lighting and receptacle Title 24 Energy. Total area: 1303 sq ft. B#1016-10000-21218	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63990	11041-10000-27306	12053 N DELANTE WAY	91344	12	216B125   379	2601072011	RA-1, T, K, O	North Valley				1266.43	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	ADDRESS	34.2916	-118.52731	Roof mounted PV system for SFD, 8.385KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63991	18041-20000-14963	20654 W WALNUT CIR	91326	12	219B109   358	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.29415	-118.58414	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63992	15041-10000-24722	8935 N ORION AVE	91343	7	195B141   247	2654001053	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.05	Electrical	Electrical	Apartment			07/31/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Expired	09/26/2017 12:00:00 AM	ADDRESS	34.23288	-118.4722	NEW FIRE ALARM FOR A NEW 3-SOTRY APARTMENT BUILDIING. SYSTEM INCLUDE (1) FIRE ALARM PANEL, (2) POWER SUPPLIES, AND  98 DEVICES.  SUBMITTAL PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63993	15041-10000-42824	739 S GARLAND AVE	90017	1	130-5A207 229	5143009015	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			12/18/2015 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.0508	-118.26704	INSTALLATION OF NEW FA SYTEM FOR AN EXISTING 3-STORY BUILDING. ( GARLAND APARTMENT) 215 FA DEVICES , ON FA PANEL AND GRAPHIC ANNONCIATOR, 1 CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
63994	14041-20000-13440	4107 S ROMA CT	90292	11	102A147    61	4295002060	[Q]RD1.5-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	33.97455	-118.46041	Roof mounted PV system with transformerless inverter.  PV system size 5.4KW.Note: Zoning Clearance is approved under 14041-20000-11614	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
63995	17041-10000-38863	2256 W COLORADO BLVD #108	90041	14	162A221   106	5686002027	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.13914	-118.21549	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO COFFEE SHOP. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 904 SQ. FT. B#17016-10000-27750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63996	12041-10002-30549	8511 W BEVERLY PL	90048	5	138B173   350	4337012040	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.07669	-118.37705	NEW  4 STORY  PRIVATE SCHOOL BUILDING OVER ONE SUBTERRANEAN LEVEL OF PARKING. PLAN CHECK FOR POWER AND ENERGY FOR AN ADDITION TO AN ACADEMY (CHARTER SCHOOL). PROJECT IS LOCATED IN A METHANE ZONE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63997	13041-10000-12829	3650 W MARTIN LUTHER KING, JR BLVD 178	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	13041-10000-12829PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR AN ADDITION OF 674 SQUARE FEET. TENANT NUMBER 178. NOTE: TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63998	12041-10000-00597	612 N SILVER LAKE BLVD	90026	13	139-5A203  15	5401022020	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.03	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM			PC Approved	01/10/2012 12:00:00 AM	ADDRESS	34.07852	-118.27851	Plan check T24 Energy/Emergency lighting for TI of commercial kitchen/sales area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
63999	17041-20000-13359	6228 N PETERSON AVE	91367	5	177B089   155	2033026026	R1-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.184	-118.64604	pv1install roof mounted pv system sized 8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64000	19041-10001-22968	3420 N BLAIR DR	90068	4	159B181    84	5579010013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.13469	-118.34563	"DELTA ""1"" CHANGES TO APPROVED PLANS. REMOVING THE ""ENPHASE IQ COMBINER"" PANEL ON PAGE 2. PLAN CHECK ONLY. PERMIT# : 19041-10000-22968<<<PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15  MODULES (PHONO SOLAR PS325M-24 AND 15 MICROINVERTERS (IQ7-60). SYSTEM SIZE IS 4.875KWdc AND 3.75KWac>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64001	16041-10000-44113	3526 N MARMION WAY	90065	1	144A223   355	5446025013	[T][Q]CM-1VL	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Apartment			01/14/2016 12:00:00 AM			PC Approved	03/09/2016 12:00:00 AM	ADDRESS	34.08726	-118.21354	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64002	14041-10000-35504	9434 N MASON AVE	91311	12	198B109    59	2748022047	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.24193	-118.57957	Remove HID fixtures and replace with LED fixtures.  Plan check for energy.COMPLY WITH DEPARTMENT ORDER effective date06/18/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64003	17041-20000-38621	19191 S VERMONT AVE 9th flr	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	12/05/2017 12:00:00 AM	ADDRESS	33.85656	-118.29099	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy indoor only.  high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64004	13041-10000-06166	440 S SEATON ST	90013	14	127-5A215 363	5163025008	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Issued	09/03/2013 12:00:00 AM	ADDRESS	34.0421	-118.23734	One of three commercial buildings supplied from a new 5000A SWITCHGEAR (MS); SWITCHBOARD (MSA) 3000A SUPPLIES THE LOADS FOR THE 3-STORIES 440S SEATON BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64005	11041-10000-23751	5004 N OAKDALE AVE	91364	3	171B113   509	2175021018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.16156	-118.5661	New 11.2KW roof mounted photovoltaic system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64006	19041-10000-34674	12710 N JIMENO AVE	91344	12	222B133   655	2602021012	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Re-Activate Permit	05/27/2020 12:00:00 AM	ADDRESS	34.30142	-118.50276	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 8.835 KWdc/6KWac. SCOPE OF WORK IS 31 MODULES (HANWHA Q-CELL 285 WATT) WITH OPTIMZERS (SE P320), LEADING TO A CENTRAL INVERTER (SE6000H-US). NOTE PANEL UPGRADE TO BE SEPARATELY PERMITTED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64007	10041-10000-12748	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM	07/02/2010 12:00:00 AM		Permit Finaled	07/07/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	New Fire Alarm system. Plan check for Power. (Permit is alredy issued # 10041-10000-05859)	N	N	Express Permit	06/10/2024 12:00:00 AM
64008	17041-10000-23894	10250 W SANTA MONICA BLVD LL#2350-(LEVEL B)	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR POWER AND ENERGY FOR  ""GDBA VIP SANCTUARY"" LOUNGE FACILITY."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64009	13041-10000-02183	8500 W BEVERLY BLVD # 675	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM			PC Approved	01/29/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT ON SUITE 675 OF AN (E) 878 S.F. RETAIL SPACE. plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64010	19041-10000-45006	3334 W SAN FERNANDO ROAD	90065	13	153B209   295	5458003028	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.11791	-118.24936	PLAN CHECK FOR ENERGY ONLY. SQUARE FOOTAGE: 8,525 NOTE: IGNORE ALL CLOUDS ON PLANS, THIS IS NOT CHANGES TO AN APPROVED SET, THIS IS A NEW TITLE 24 PLAN CHECK , NOTE ALL PERMIT FEES WILL BE UNDER INSPECTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64011	19041-10000-48834	1948 N APEX AVE	90039	13	145-5A207 120	5422017001	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.09234	-118.26102	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 7.04KWdc (6.62KWac) USING 21PANASONIC VBHN335SA17 MODULES, & 21 ENPHASE IQ7X MICROINVERTERS. ESS TESLA POWERWALL.CONNECTED TO A 200 AMP EXISTING SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64012	11041-10003-01491	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	New fire alarm system for the Tom Bradley terminal. EPC is for power. (South concourse) ((((( addition of vesda systems to previously approved set 10-19-11 )))))))))))))))))))))))))Delta 6,, changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64013	18041-10002-05899	3303 N NORTH BROADWAY FLR 2, 3	90031	1	138A225    15	5208012021	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	34.07394	-118.20626	"Changes to approved plans for installing additional ""EXIT"" signs per LAFD's request.Plan Check Only. Permit #: 18041-10000-05899(((PC for power and energy for medical office building TI. Installing new panels, lights, receptacles and equipment. Total 39235sqft. B# 18016-10000-04041."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64014	19041-10001-05573	736 N FULLER AVE	90046	5	141B181   369	5526008005	R1-1	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.0847	-118.3497	"DELTA ""1"" CHANGES TO THE APPROVED PLANS FOR RELOCATING PV EQUIPMENT.<<<NEW ROOF MOUNTED 9.45 KW PV SYSTEM WITH 31 PV PANELS ON A SINGLE FAMILY HOME.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64015	11041-10001-26987	1425 E 6TH ST	90013	14	126A217   118	5164007017	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM	PIN	34.03864449	-118.2318869	Changes to approved plans. New walls and several new fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64016	13041-20000-25623	4920 N BALBOA BLVD	91436	5	168B133    77	2259010001	C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	PIN	34.15988743	-118.50066576	SERVICE UPGRADE TO 1600A FOR SHOPPING CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64017	13041-20000-07963	18700 W VENTURA BLVD STE 150	91356	11	174B121   811	2161026002	(Q)C2-1VL, C2-1VL, R1-1	South Valley, West Los Angeles	Encino - Tarzana, Palms - Mar Vista - Del Rey	Mar Vista, Tarzana		2719.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.17045	-118.54081	Plan check for first-time tenant. PANEL ONLY. Suite 150. MAC Cosmetics.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64018	17041-10001-06151	14006 W RIVERSIDE DR 112/122	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM			PC Approved	03/23/2017 12:00:00 AM	ADDRESS	34.15713	-118.43792	03/23/17Changes to approved set of plans. Changes include to reflect what is on the field. Changes include adding an exit sign to reflect architectural plans, and removing unit equipment from floor plans(Using emergency system for emergency lights). Note: Permit is paid under PCIS#17041-10000-06151	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64019	15041-20000-12939	8314 N SEPULVEDA BLVD	91343	6	192B145   381	2654026042	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.30	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.22191	-118.46752	TI to existing commercial building. Change of use from restaurant and bar to adult cabaret. Plan check for power and energy. Total sqft. 2,905	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64020	18041-10000-05147	415 E MANITOBA ST	90293	11	093B153   117	4117030017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Issued	02/12/2018 12:00:00 AM	ADDRESS	33.95337	-118.44194	Plan check for battery back up system to existing PV system. Install one power wall 2.0 with PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64021	17041-20000-45568	18800 W COVELLO ST	91335	3	186B121   300	2118004021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.20737	-118.54276	Plan check for solar pv system w/roof-mounted array for SFD.10.4kW ungrounded system. (2) 5.2kW inverters.(29) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64022	18041-10000-16497	8905 W VENICE BLVD 109	90034	5	123B169  1508	4312011036	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.02929	-118.38914	Energy plan check for a take out restaurant. Scope includes new lighting and equipment. Total area is 1014-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64023	13041-10000-26655	2000 S AVENUE OF THE STARS 12THFLOOR	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	ADDRESS	34.05868	-118.41546	TITLE 24 PLAN CHECK ONLY. EMERGENCY LIGHTING. 9008 SQFT. HIGH RISE TENANT IMPROVE MENT ON THE 12TH FLOOR. CHANGES TO APPROVED SET OF PLANS, CHANGES ARE CLOUDED. PREVIOUS T24 PLAN CHECK UNDER 13041-10000-19704.ALL CORRIDORS EGRESS APPROVED UNDER SEPERATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64024	14041-20001-11692	2153 N GROVELAND DR	90046	4	151-5A173 130	5567010003	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.11008	-118.37618	((expedite fees)))mel@precisesolarenergy.compv1 single family. using enphase m215 microinverter. nonstandard plan. system size 4.08kw ac using 19 modules. e-mail applicant upon completion of plan check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64025	14041-10001-10950	1801 S FIGUEROA ST	90015	9	124-5A205 282	5126002009	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM			Reviewed by Supervisor	06/24/2014 12:00:00 AM	ADDRESS	34.03524	-118.27179	changes to approved plans: per applicant due to field conditions - oil and air equipment in driveway forced relocation of service equipment routing. service equipment moved. (E) panel G to be used instead of NGA. plan check for power only. .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64026	17041-10002-10219	16887 W CALLE DE SARAH	90272	11	138B117    49	4431038004	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.07782	-118.55268	REVISIONS TO APPROVED SET TO REFLECT CORRECT SERVICE INFORMATION ON THE PLAN. CHANGES INCLUDES REVISING SERVICE FROM 400A TO 200A THIS IS PLAN CHECK ONLY! PERMIT  FEES UNDER MASTERPV INSTALLATION OF A NEW 12.600 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A RESIDENTIAL HOUSE(35)MICRO INVERTER: SPR-X22-360-C-AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64027	15041-10001-42382	12130 W MILLENNIUM #  02-129	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	33.98008	-118.40646	Supplement per mit to permit # 15041-10000-42382. Change to approved set of paln for Title 24 only in restroom and new break room. ((((((((INTERIOR TENANT IMPROVEMENT.PLAN CHK IS FOR TITLE 24)))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64028	17041-10001-19302	380-384 WORLD WAY MSC-F/A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	DELTA 4 CHANGES TO THE APPROVED PLANS. ADDING NEW FA DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64029	17041-10000-40695	803 W BEJAY PL	90731	15	024B197   222	7442018001	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	33.76099	-118.29574	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 5.44KWDC/4.93 KWACSCOPE INCLUDES 17 MODULES WITH MICROINVERTERS (IQ6 PLUS) AND NEW LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64030	17041-20001-38956	23534 W HATTERAS ST	91367	3	174B093   126	2041009010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM			PC Approved	02/07/2018 12:00:00 AM	ADDRESS	34.17537	-118.63964	02/07/2018 Changes to an approved set of plans. OCPD for the subpanel has been revised. Load calculations for subpanel have been provided.*****Previous Work Description*****Install 13.5 kWh energy storage system for SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64031	15041-10000-02880	3827 W SUNSET BLVD #E	90026	13	145-5A203 411	5429014040	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM			PC Approved	01/30/2015 12:00:00 AM	ADDRESS	34.09153	-118.27923	Plan check for T-24 only.  T. I. Total area: 565SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64032	15041-20000-17265	2275 N CHELAN DR	90046	4	153B181   305	5572011030	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM			Reviewed by Supervisor	06/09/2015 12:00:00 AM	PIN	34.11307861	-118.34795154	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (42) modules, and (42) dc/dc converters. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64033	11041-20000-16744	1001 S GAYLEY AVE #100	90024	5	132B149    43	4363025012	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	08/09/2011 12:00:00 AM		Permit Finaled	09/20/2011 12:00:00 AM	ADDRESS	34.06169	-118.44797	PLAN CHECK T24 ENERGY/EMERGENCY RETAIL TENANT IMPROVEMENT #100. PERMIT FOR NEW CKTS, EQUIPMENT, PANELS, AND WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64034	11041-10000-20036	600 W WORLD WAY TERMINAL 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM	09/20/2011 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	NEW CONVEYOR AT LAX TERMINAL 6/// tHIS PROJECT WAS APPROVED UNDER APPLICATION #     11041-10000-18925----- FEES WERE CALCULATED WRONG . TO FIX THIS PROBLEM APPLICATION IS COPIED TO A NEW PERMIT # AND PROCESSED ON THE COUTER PLAN CHECK.  CUSTOMER WILL APPLY FOR REFUND ON THE OLD PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64035	17041-10001-12650	2330 N FLETCHER DR	90039	13	150A209   194	5438015056	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/12/2017 12:00:00 AM	ADDRESS	34.10484	-118.25807	TI FOR BEAUTY SALON - MASSAGE. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED TO COLLECT CODE ENFORCEMENT INVESTIGATION FEES. REFER TO CASE NUMBER 741973	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64036	14041-10000-10255	1100 S SAN PEDRO ST # N09	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.03515	-118.25194	T24,REMOVE HID LIGHTING FIXTURES AND REPLACE WITH NEW FUORESCENT FIXTURES. TOTAL AREA 527 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64037	10041-10000-01939	10250 W SANTA MONICA BLVD Unit #32	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	04/14/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Tenant improvement for existing retail store.  Install new general and emergency lights.  Plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64038	16041-10000-20673	1669 E 50TH PL	90011	9	111A213   248	5106024011	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Expired	07/17/2018 12:00:00 AM	ADDRESS	33.99715	-118.24399	PV1 INSTALL NEW 4.24 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(16) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64039	15041-10000-20904	17150 W VOSE ST	91406	6	183B133   467	2227024009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.19837	-118.50727	PV1SOLAR PV STANDARD PLAN CENTRAL STRING INVERTER SYSTEM SIZE 7.6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64040	10041-10000-20081	7265 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	POWER AND MONITORING WIRING FOR THE INSTALLATION ABOVE GROUND 2 EA SKIDS AND TANKS FOR THE BULK LOADING OF FUEL DELIVERY TANKS/TRUCKS  AT THE LAX AIRPORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64041	15041-10000-16207	7280 W MELROSE AVE	90036	5	141B181   623	5525013027	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	PIN	34.08325977	-118.34845856	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  NEW 600 AMP SWITCHGEAR, NEW PANELS AND CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 3865.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64042	10041-10000-01040	2429 W TEMPLE ST	90026	13	138A205   168	5157006007	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10, 2085.00	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM	01/27/2010 12:00:00 AM		Permit Expired	07/31/2012 12:00:00 AM	ADDRESS	34.07208	-118.27308	UPGRADE SERVIC ETO 800A TO MIXEDCOMMERCIAL/RESIDENTIAL BUILDING. ALL LOADS ARE EXISTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64043	07041-10002-00260	7401 S SEPULVEDA BLVD	90045		102B165   569	4110003007	RD1.5-1XL		Westchester - Playa del Rey	Westchester - Playa del Rey			Electrical	Electrical	Apartment			10/25/2010 12:00:00 AM			PC Approved	11/01/2010 12:00:00 AM	ADDRESS	33.97414	-118.39462	Change to the priviously approved plan. Revisions to unit panel schedules . Some loads were deleted and replace; other loads were supplied from a different circuit designation. All under delta 3 revisions. ((((((((((((((((((NEW 24-UNIT / 2-STORY APARTMENT WITH SUBTERRANEAN GARAGE.))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64044	15041-20000-43340	515 S FLOWER ST 28TH FLOOR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Expired	01/26/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	PLANCHECK FOR T24 ENERGY. TI FOR ELECTRICAL ROOM. BANK OF AMERICA. HIGH RISE. 28TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64045	13041-20000-24298	12989 N NORRIS AVE	91342	7	222B149   518	2506013005	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.30542	-118.45739	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.82KW. 14 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64046	11041-10001-02634	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/04/2011 12:00:00 AM			PC Approved	03/04/2011 12:00:00 AM	ADDRESS	34.04835	-118.25882	Change the approved plan. EPC is for delta 1 changes. ((((((((((((((TI FOR A COFFEE SHOPE KIOSK INSIDE THE SHOPPING MALL. EPC IS FOR T24 & ENERGY.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64047	11041-20000-23155	16917 W ENADIA WAY	91406	6	183B133   223	2227026023	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM			Plans on Hold	11/10/2011 12:00:00 AM	ADDRESS	34.20024	-118.50181	medical imaging center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64048	18041-10000-01328	1515 N VERMONT AVE 8 TH Floor	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM			PC Info Complete	01/12/2018 12:00:00 AM	ADDRESS	34.09867	-118.29207	Plan check for Title 24 only in existing space pharmacy(None patient care area) Medical office building. Total are: 279 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64049	16041-10000-45790	380-384 WORLD WAY MSC   Temp-Power	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan Check for Temporary power for MSC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64050	17041-20000-00594	865 S FIGUEROA ST 35th flr	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.04653	-118.26275	ti to an existing commercial building high rise 35th floor.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 15450.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64051	15041-10001-01354	200 WORLD WAY TERM 2-ARRI LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check for changes to proposed lighting system.  (((TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 ARRIVAL LEV 1  SPACE 283PLAN CHK IS FOR TITLE 24)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64052	13041-20000-00437	21650 W OXNARD ST 12th Floor	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for T-24 and emergency lighting. Commercial high-rise. 12th Floor. 19359sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64053	19041-20000-28119	5814 W LA MIRADA AVE	90038	13	144B189   220	5534019018	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM			Reviewed by Supervisor	08/29/2019 12:00:00 AM	ADDRESS	34.09365	-118.3162	Permit issued under 19041-20001-28119New 16-unit 4-story apartment building. 800A 240/120V 3ph-4w service.Building permit under 18010-20000-04194	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64054	15041-10000-07329	6100 N SEPULVEDA BLVD	91411	6	177B145   597	2242025023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.18076	-118.46437	PC FOR POWER AND ENERGY. ADD NEW DIESEL TANK AND 4 NEW DISPENSER AND REPLACE 6 ESIXTING DISPENSER LED CANOPY LIGHTS. ADD NEW PANEL. GAS STATION. HAZARDOUS AREA. TOTAL AREA 5138 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64055	16041-10001-44546	10250 W SANTA MONICA BLVD # 2730	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM			PC Approved	03/17/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 12 AND 13 ON PLANS. PROVIDED T24 DOCUMENTS ON DRAWINGS AND CORRECT ENGINEER INFORMATION. ALSO PROVIDE PHOTOCELL AND DIMMIBLE CONTROLED REQUIREMENTS. THIS APPLICATION IS PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64056	11041-20000-08238	1888 CENTURY PARK EAST 16TH FLOOR	90067										Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM			PC Approved	05/09/2011 12:00:00 AM				T-24 OTC PLAN CHECK WITH EMERGENCY LIGHTING.  EX. OFFICE TI.  16TH FLOOR PAUL MITCHELL SYSTEMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64057	10041-10002-22559	4501 W COLORADO BLVD BLDG  8	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM			PC Approved	04/23/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	REVISIONS TO LIGHTING PLANS- MODIFICATION TO ALLOW ANNUNCIATED LIGHT SWITCHES LOCATED IN A CONTROLLED ACCESS ELECTRICAL ROOM ON THE IST FLOOR  TO MEET TITLE 24  AREA LIGHTING CONTROL; DELTA 14 CHANGES((((((((( NEW 2-STORY MANUFACTURING FACILITY WITH PARTIAL BASEMENT AND TWO EQUIPMENT PLATFORMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64058	18041-10000-20299	20000 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.27519	-118.57042	INSTALL A NEW FIRE ALARM SYSTEM IN A NEW 3 STORY MEDICAL OFFICE BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64059	15041-20000-03880	7641 N BURNET AVE	91405	6	186B145    60	2209034002	P-1, [Q]CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.20962	-118.46305	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS INTO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 12664.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64060	15041-10000-02592	380 W WORLD WAY T90	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check for Title 24 Sign Lighting only. Permit is for (2) branch circuits for indoor sign lighting (sign is within Tom Bradley Terminal; sign is not visible from right-of-way).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64061	19041-10000-26107	14061 W ROSCOE BLVD Bldg B	91402	6	192B153   770	2638037017	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	04/20/2022 12:00:00 AM		Issued	04/20/2022 12:00:00 AM	ADDRESS	34.22179	-118.43948	PC FOR FIRE ALARM FOR 2 BUILDINGS, BUILDING I STORY HIGH AND BULDING IS 2 STORY. 1-FACP AND 233 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64062	19041-10000-47990	12121 W WILSHIRE BLVD 14th flr	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM	03/19/2020 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	34.04386	-118.46816	Energy only Plan check. Area scope (10,430)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64063	17041-10001-24511	19710 W ARUNDEL PL	91364	3	171B117   454	2175014029	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Tarzana, Woodland Hills - Warner Center		1375.04	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.16246	-118.56363	EXPEDITE FEESPC FOR PV SYSTEM. USING 30 MODULES. USING AC PANELS. TOTAL SIZE 10.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64064	18041-10000-38768	131 E 50TH ST	90011	9	111A205   273	5109004054	RD2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2293.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	33.99755	-118.27331	REMOVE OUTDOOR/INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64065	13041-10000-19003	1038-1040 W PRINCETON DR	90292	11	105B149   499	4229003049	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	33.9859	-118.44654	Title 24 plan check for low-rise commercial building exterior lighting and electrical room lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64066	16041-10000-06101	118 S AVENUE 50 BUILD. 4	90042	1	150A225   277	5467014008	R3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.20	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.1042	-118.20184	CONSTRUCT NEW CONDOMINIUM BLDG..4, 6 UNITS, 600MSA, T-24 LTO only. TOTAL TITLE 24 LIGHTING AREA: 2,097 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64067	17041-20000-04976	7617 N WISCASSET DR	91304	12	189B085    20	2017032010	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.21146	-118.65892	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.29 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64068	18041-20000-31328	3745 S GRAND AVE	90007	9	117A203    86	5122025002	[Q]C2-2, [T][Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.01543	-118.27934	Plan check for power only. Project site is an existing 4-story commercial building. Project scope is a service upgrade to 600-amps. Existing loads will be re-fed and circuits will be added to power A/C units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64069	14041-10000-07867	1200 S CLUB VIEW DR 1-35	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			03/25/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.06748	-118.42481	T24 FOR CORRIDORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64070	18041-20000-05807	17641 W RAYEN ST	91325	12	195B129   188	2768027008	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.23234	-118.51936	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of a Tesla PowerWall to an existing roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64071	17041-20002-38957	3627 N CODY ROAD	91403	4	159B145    65	2278024004	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.1361	-118.46394	Revision to approved set of plans.  Fused disconnect added to plans; bus rating of main service panel changed to 200A.  (((Installation of 27 kWh energy storage system for SFD.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64072	14041-10000-29323	10780 W SANTA MONICA BLVD 1st - 4th	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.0504	-118.43387	Energy plan check for restrooms in a commerical building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64073	14041-10000-18327	349 N SYCAMORE ROAD	90402	11	123B129   705	4410018024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.03155	-118.51601	Install roof mounted solar pannels with a single inverter ungrounded system.  Total size = 5 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64074	18041-10000-37420	14422 W VENTURA BLVD	91423	4	166-5A151 174	2266001017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Issued	10/02/2018 12:00:00 AM	ADDRESS	34.15042	-118.44668	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64075	15041-10000-12519	600 WORLD WAY TERM 6-T-649	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR POWER AND ENERGY. TERMINAL 6 OF LAX. FIRST TIME TENANT . TOTAL  AREA  IS 610 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64076	16041-10001-02630	10705 W PENROSE ST Unit A-C	91352	7	195B177   108	2544027007	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.23241	-118.36447	5.26.2016 - Plan check for modifications to approved set. Update single line diagram, change interconnection from line side tap to subpanel breaker. Changes clouded. Sheet E-1.0. Covers Units A, B, and C. Original plan check permit #16041-20000-02638/02636/02630 and PCAM number E16VN00205.====Plan check for a PV2 roof-mounted PV system. System size is 2.2 kWac and consists of (10) modules, (10) micro-inverters, and (1) load center. Multi-tenant building (3 tenants) will have a total of (3) PV systems interconnecting to it.Note: Solar clearance shall apply to all (3) tenants.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64077	18041-10000-03110	400 S BROADWAY	90013	14	129A211   293	5149024***	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	34.04925	-118.24934	PC FOR POWER AND ENERGY  FOR  New 35 story mixed use building: 450 units residential condominium ,core and shell only retail, 6 levels garage above grade, and 1 level  garage below grade.PROPOSED SERVICE 1200A 4160V 3PH AND INCULDES 5 SUB STATIONS . Modification to separate fire alarm plans has been submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64078	15041-10000-34604	13425 W SHERMAN WAY	91605	2	183B157    25	2328026011	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.20136	-118.42552	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64079	17041-10000-37401	330 W PICO BLVD	90015	14	126A207   204	5134025042	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			PC Info Complete	10/17/2017 12:00:00 AM	ADDRESS	34.03851	-118.26401	PC FOR SERVICE UPGRADE FOR A COMMERCIAL BUILDING. SERVICE SIZE 3 PH 800A 120/240VSCOPE INCLUDES SERVICE EQUIPMENT ONLY.  ALL OTHER WORK TO BE UNDER FUTURE PERMIT. CAUTION!! LOCATION IS IN METHANE ZONE	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64080	11041-10000-10296	1025 N HIGHLAND AVE 14th fl	90038	4	144B185   830	5532028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.08969	-118.33884	FIRST TIME TENANT.  ALL NEW ELECTRICAL FOR 14TH FLOOR.  DISTRIBUTUION PANELS, XFRMRS, LIGHTING AND POWER.  APPLICANT WILL FILE FOR VARIANCE TO SEPERATE FIRE-ALARM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64081	12041-10000-20692	4105 S 11TH AVE	90008	8	114B185   359	5024026015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.00983	-118.32971	Plan check for new roof mounted 3.27KW Photovoltaic System (Aurora Transformerless inverter). Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64082	16041-20000-06277	18256 W RAYEN ST	91325	12	195B125   444	2769022025	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.23175	-118.53152	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (28) modules, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64083	19041-10000-11407	111 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00, 3200.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM			PC Info Complete	05/14/2019 12:00:00 AM	ADDRESS	34.13855	-118.36112	PC for installing a new 1200 A distrubition board connected to an exitising emergency generator. Along with new ATS (3 pole, 800A)  feeding new 800 A distrubition board and  exitising emergency loads. Load calculations for generator are being updated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64084	15041-10000-22118	1824 S MAGNOLIA AVE	90006	1	126A201   117	5056012001	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.04056	-118.28622	REMOVE EXISITNG HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64085	14041-20000-16588	1100 S GLENDON AVE suite 1200	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.06074	-118.44418	Plan check for energy only. New lighting (incl. emergency) in office on 12th floor of high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64086	11041-10000-18449	760 W WASHINGTON BLVD 1-4	90292	11	105B149   150	4229016041	C2-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	PIN	33.9874216	-118.45286721	FIRE WARNING SYSTEM  FOR A 4 UNITS TOWNHOMES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64087	15041-20000-22589	7603 COURAGE WAY	91405	6	186B145  1156		(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20871501	-118.46444917	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64088	17041-20000-16813	5670 W WILSHIRE BLVD 23RD FLOOR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	PLANCHECK FOR T24 ENERGY. RESTROOM AND CORRIDOOR LIGHTING. 1575 SQFT. 23RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64089	16041-10000-29608	1641 N IVAR AVE	90028	13	148-5A187 207	5546008022	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.10097	-118.3283	T.I OF BASEMENT, GROUND AND MEZZANINE LEVEL OF A COMMERCIAL  2-STORY BUILDING. TOTAL AFFECTED OUTDOOR FOR T-24 IS 14,273 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64090	18041-20000-20268	600 S SAN PEDRO ST	90014	14	127-5A213 510	5147026033	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.04202	-118.24515	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64091	10041-20000-02589	11900 W OLYMPIC BLVD #770	90064	11	123B149   541	4259024003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	02/16/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.03252	-118.45186	office t.i.Energy, emergencyFire Alarm System is by others 09041-10000-19133	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64092	13041-10000-05902	2001 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	PIN	34.06587468	-118.19737837	FIRE ALARM SYSTEM FOR WAREHOUSE. TOTAL DEVICES : 66. 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64093	14041-10000-27324	11226 N TAMARACK AVE	91331	7	210B153   303	2616021051	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.27388	-118.43481	PV1 standard plan, 5kw roof-mounted system including (1) Solaredge SE5000A inverter,(22) Kyocera KD255 modules and Solaredge P300 power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64094	15041-10000-00041	22815 S FRAMPTON AVE	90501	15	045B197    50	7347018031	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			01/02/2015 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	33.81849	-118.2997	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 12412 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64095	12041-20000-16161	6333 W 3RD ST Bldg E-# E16	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM			PC Approved	07/12/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	Adding 21 new and relocation 4 MH floor and wall display lights in space # E16 of building E.   No effect on existing emergency lighting system.  Plan check for T-24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64096	13041-20000-31493	20352 W KESWICK ST	91306	3	186B113    95	2114002013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.20957	-118.57715	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 4.5KW. 18 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64097	18041-10000-33113	5325 W 102ND ST	90045	11	090B173   165	4129030014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	33.94375	-118.37333	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64098	11041-10000-08354	415 N MISSION ROAD	90033	14	130-5A219  46	5410006008	[Q]M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM			PC Approved	04/26/2011 12:00:00 AM	ADDRESS	34.05361	-118.22654	TI TO WAREHOUSE OFFICES.  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK ONLY.  <<<<<<<<<<<<<EMERGENCY LIGHTING WAS REMOVED FROM THE PLAN, NO EMERGENCY LIGHTING WILL BE INSTALLED>>>>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64099	14041-10000-13092	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	TI FOR EXISTING OFFICE SPACE. NEW CIRCUITS ARE SERVING THE POWER ONLY, ALL LIGHTING CIRCUITS AND EXIT SIGN CIRCUITS ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64100	18041-10001-32221	1411 E NEWTON ST	90021	14	121-5A213 230	5130010038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM			PC Approved	07/25/2019 12:00:00 AM	ADDRESS	34.02618	-118.24419	Changes to approved set, changes include new additions  lighting fixture schedule and updating T24 accordingly. Affected area remains the same. Permit is pulled under master application 18041-10000-32221	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64101	18041-10000-06912	10171 N LEV AVE	91331	6	204B153   522	2617001031	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.2555	-118.439	PC for 5kW(ac) rooftop solar system for SFD. Installing 19 modules [5.51kW(dc)] with optimizers and  5kW central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64102	16041-10000-39192	917 N BEAUDRY AVE	90012	1	136-5A213 102	5406021032	R3-1	Central	Central City North	Historic Cultural		1977.00	Electrical	Electrical	Apartment			11/04/2016 12:00:00 AM	03/29/2019 12:00:00 AM		Issued	03/29/2019 12:00:00 AM	ADDRESS	34.06783	-118.2467	Plan check for new appartment building 4 story 18 units.1,200 A Service. Methane Zone.Note: Fire Alarm Variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64103	13041-10000-10128	467 E VERNON AVE	90011	9	112-5A205  13	5113015801	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM			PC Approved	04/23/2013 12:00:00 AM	ADDRESS	34.00402	-118.26743	Energy plan check for gutted existing single story office building.  Building was previously an AT&T payment center, is now being gutted and converted to AT&T general office usage.  5769 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64104	16041-20001-40276	850 N MARIPOSA AVE	90029	13	141B197   109	5538006038	RD1.5-1XL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.08618	-118.29884	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 37.7kW (6kW*5+7.7kW) ungrounded system. (136) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64105	14041-20000-15932	3107 S THATCHER AVE	90292	11	105B149   162	4229008025	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	33.98741	-118.44932	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64106	18041-10000-42402	4141 S LINCOLN BLVD	90292	11	105B153    37	4229004034	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	33.98722	-118.44507	REPLACE INDOOR/OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64107	14041-20000-23439	7020 N LURLINE AVE	91306	3	183B109   431	2137014008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.19815	-118.58349	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.5KW INTERCONNECTED WITH MSP.STANDARD PLAN MICROINVERTERS.FIRE DECLARATION SIGNED PER REQUIREMENT NO. 96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64108	19041-10000-13333	5870 W JEFFERSON BLVD SUITE E	90016	10	120B173   383	4205027010	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM			PC Approved	04/11/2019 12:00:00 AM	ADDRESS	34.02285	-118.37583	TENANT IMPROVEMENT FOR OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64109	10041-20000-16154	5670 W WILSHIRE BLVD #640	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			08/18/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	ADDRESS	34.06222	-118.35208	Plan check T-24 Energy (general/emergency) lighting for Hair Spa suite #640.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64110	17041-20002-22682	3530 W WILSHIRE BLVD	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM			PC Approved	03/21/2019 12:00:00 AM	ADDRESS	34.06154	-118.30122	3/7/2019CHANGE TO APPROVED SET, CHANGE FROM 688 PHONO SOLAR 325W PV MODULES TO 649 HANWHA Q CELLS 390W PV MODULESTHIS IS PLAN CHECK ONLY.*original*((((Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,054) modules, and (1) load center on parking structure. Note: Permit Fees $0 Due to SB 1222 Note: Building application has been generated under 17014-30000-03172))))((((7/31/2018changes to an approved set of plans.  changes to reduce system size to 180KW AC with line side tap.  (688) phono solar 325W(3) yaskawa solectria 60KWThis is plan check only.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64111	15041-20000-31531	6083 W PICO BLVD	90035	5	129B173   143	5087010025	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM			PC Info Complete	09/23/2015 12:00:00 AM	ADDRESS	34.05297	-118.37336	TI to existing commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 2,820.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64112	12041-20000-10548	14401 W VENTURA BLVD	91423	4	166-5A151 296	2265014017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	34.15069	-118.44613	Install new canopy outdoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64113	17041-10000-11634	18181 W BURBANK BLVD	91356	3	174B125   367	2157007059	(T)(Q)RD2-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.17248	-118.52891	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 10250 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64114	12041-10000-30630	601 S FIGUEROA ST 11TH-FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR TITLE 24.  TENANT IMPROVEMEN TO THE ENTIRE 11TH FLOOR OF A HIGH RISE (GENERATOR). USING AREA CATEGORY FOR 16,940SQ FT (< 30,000).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64115	19041-20002-17613	10573 W SCENARIO LANE	90077	5	151-5A151 554	4380009022	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM			PC Approved	10/08/2019 12:00:00 AM	ADDRESS	34.1094	-118.44895	Plan check fee is $0.00 due to AB1414 and AB1222.Supplemental plan check only, changes to approved set, clouded changes only. Adding to AC disconnects, minor changes to site plan, property plan, elevation drawing, and single line.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64116	14041-20000-29888	1722 N BRIDGEPORT DR	90065	1	148-5A219  34	5464028047	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.10275	-118.22741	PV1Install roof mounted solar array on SFD. Interconnect with 200A MSP.System size 6kW. Grounded system.20 327W pv modules across 3 strings (6+7+7).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64117	11041-10000-22687	6150 W OLYMPIC BLVD	90035	5	132B177   643	5087025044	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Apartment			10/24/2011 12:00:00 AM	10/24/2011 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	PIN	34.05803526	-118.36522127	New 600A service, MS, and sub-panels for an existing apartment complex.  No new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64118	18041-10000-03800	320 N MADISON AVE	90004	13	138B197   191	5501002032	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	05/04/2020 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.07708	-118.28902	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYTEM SIZE IS 9.10KWdc / 9.00KWac. (26)MODULES-Hyundai His-S350TI(26)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE9KUS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64119	14041-10001-19481	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	34.11883	-118.2495	Addition of 3 door holders to approved set.*****Previous Work Description*****Fire alarm system for new building and existing building.  Total number of devices = 466	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64120	13041-20001-35922	206 N KENTER AVE	90049	11	132B141    66	4403011007	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.06124	-118.48025	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING SOLAR OPTIMIZERS. TOTAL SYSTEM SIZE 6.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64121	17041-10000-04559	2225 S CARMELINA AVE	90064	11	123B149   849	4259026015	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.03006	-118.45548	Plan check for Title 24 only outdoor lighting in exiting space T.I. Fortune Investment  Co. LP. newly conncted load is less than 400A. Total area: 10,735 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64122	10041-10000-03024	7955 N VINELAND AVE	91352	6	189B173   272	2314007085	[Q]C2-1L-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	Commercial			02/22/2010 12:00:00 AM			PC Info Complete	12/08/2011 12:00:00 AM	ADDRESS	34.21536	-118.37053	T.I. for Jack-in-the-Box restuarant.  New 600A service and new building electrical sytem.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64123	15041-10000-05583	1805 E INDUSTRIAL ST	90021	14	124-5A217 122	5164012022	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.03596	-118.23418	T24 ONLY.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 16744 SQ FT. THE PLAN CHECK FEE COVERS BOTH BUILDING #1 AND #2, THE PERMIT FEE COVERS JUST BUILDING #1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64124	14041-10000-13475	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.05903	-118.41293	Title 24 for commercial high rise existing spacetotal area = 2011 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64125	13041-20000-22654	8960 S LILIENTHAL AVE	90045	11	096B169  1058	4123015002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Issued	09/12/2013 12:00:00 AM	ADDRESS	33.95549	-118.38619	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC. 54 MODULES AND 2 INVERTERS. ROOF MOUNED SOLAR, FEES HAVE BEEN CAPPED. FINAL FEE PERIOD NO CHARGE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64126	15041-20001-25200	6179 N VAN NUYS BLVD	91411	6	178-5A151 372	2241020001	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Issued	08/21/2015 12:00:00 AM	PIN	34.18253063	-118.44914999	Title 24 plan check only.  Total area = 3,405 s q. ft.  Change of use from retail to office.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64127	17041-20000-17084	8500 S FIGUEROA ST	90003	8	097-5A201 184	6032035043	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.96105	-118.28251	Plan check for energy only. New oudoor lighting for school parking lot and bicycle parking area. 4,630sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64128	12041-20000-08171	6333 W 3RD ST Space No.-011	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM	06/04/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	TI for existing retail space. Plan check for energy and emergency lighting. Farmer's Market. Space No. 011. 2418 conditioned sqft.. Dylan's Candy Bar.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64129	12041-20002-04738	21501 W ROSCOE BLVD	91304	12	192B105   592	2779036021	C2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Apartment			07/01/2014 12:00:00 AM			PC Approved	07/01/2014 12:00:00 AM	ADDRESS	34.21994	-118.59892	Modifications to approved set to match field installation.  (((81 unit (3) story plus loft level apartments over basement garage parking.  Parallel Design-Permitting Program 30% submittal, zoning only, no green, no disabled, no life-safety, no structural.variance for fire alarm on file)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64130	16041-20001-31717	3850 S CRENSHAW BLVD	90008	10	117B185   775	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.01602	-118.33474	"Revisions to original approved set.  Additional 30 HP elevator motor added to SLD, relocation of loads from panel to panel to accommodate additional loading.  (((TI TO AN EXISTING BUILDING.  REPLACEMENT OF EXISTING PANELS ONE FOR ONE.  ADDITION OF NEW PANEL ""AC"" NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 9905)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64131	13041-20001-33562	24642 W STONEGATE DR	91304	12	186B089    55	2017029009	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.20975	-118.6573	EXPEDITE FEES ONLY        New 11.25 kw rooftop PV modules for an existing sfr.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64132	18041-20000-29247	11147 W LA MAIDA ST	91601	2	168B173   269	2353020020	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			08/03/2018 12:00:00 AM			PC Info Complete	10/01/2018 12:00:00 AM	ADDRESS	34.15885	-118.37383	New 12 unit 4-story apartment building with 1000A 240/120V 3ph-4w service. Building permit issued under 17010-20001-03312.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64133	17041-20000-16272	14840 W COBALT ST	91342	7	228B149   591	2502010002	RA-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Issued	05/16/2017 12:00:00 AM	ADDRESS	34.31935	-118.45588	pv1install roof mounted pv system sized 5.2kw interconnected with msp.  standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64134	18041-20000-24385	20752 W SPRUCE CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.29489	-118.58646	pv1install new roof mounted pv system sized 4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64135	12041-10003-14539	15100 W VENTURA BLVD	91403	4	168B145  1071	2276006021	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			PC Approved	01/22/2013 12:00:00 AM	ADDRESS	34.15292	-118.46192	REVISED PERMITTED SET OF PLANS--CHANGE TWO OPEN OFFICES TO ENCLOSED OFFICES AND ADDED 2 EA CHANDELIERS AND A FEW OUTLETSPLAN CHK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64136	15041-20001-30800	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM			Reviewed by Supervisor	10/02/2015 12:00:00 AM	ADDRESS	34.28583	-118.51165	EXPEDITED FEES FOR ROOF PV SYSTEM(((PV1 ROOF MOUNTED SYSTEM, INTERCONNECT WITH 400A MSP. (38) MODULES AND (2) INVERTER. TOTAL SIZE 8.4.(38) KYOCERA #KU2656ZPA(2) ABB#PV1-4.2-OUTD-S-US-Z-A)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64137	18041-10001-09764	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	33.84481	-118.30379	DESIGNED BUILD PROJECT. Change to approved set by modifying the floor plan and adding (3) more equipment. All changes under delta-3 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64138	19041-20000-38030	20242 W VIA MADRIGAL	91326	12	219B113   291	2701062006	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.29619	-118.57411	Plan check for PV roof mounted system, PV system size: 11.34KW with 36 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64139	14041-10000-01821	100 N LA CIENEGA BLVD	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.07466	-118.37629	pc for power and energy. new restaurant. clarify service14016-1000-01192	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64140	10041-10000-18851	650 N LA CIENEGA BLVD	90069	5	141B173   519	5528017023	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.08325	-118.37631	TI IN AN EXISTING RESTAURANT. PLAN CHECK FOR T24 AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64141	18041-10000-24858	1725 N ARGYLE AVE	90028	13	148-5A189  68	5546030002	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Expired	01/12/2023 12:00:00 AM	ADDRESS	34.10252	-118.32534	Plan check for T24only, for new single story storage and loading dock build. with basement. Loads are fed from existing service and existing distribution board. New connected load < 200A. Total area: 6,666 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64142	16041-20000-27936	221 N FIGUEROA ST 11th and-12th Floor	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	34.05882	-118.25099	Plan check for energy only. TI to existing office in high rise building. New and relocated lighting (incl. emergency). New receptacles. 5,355sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64143	13041-10000-06532	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/13/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	TI , title 24 only - 600 sqft in mall suite number 969	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64144	19041-20000-42427	2123 N HOLLY DR	90068	4	151-5A187 234	5576004057	RD2-1XL	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	PIN	34.10951294	-118.3302565	PV1.  Install 4.29 kW DC roof mounted grid tied PV system.  (13) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64145	15041-10001-32738	12307 W 6TH HELENA DR	90049	11	129B141    10	4405040007	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.05367	-118.47844	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL NEW 18.9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(63) MODULES:  SUNPERME SNPM-GXB-300()INVERTER:  SOLAREDGE SE7600A-US & SE11400A-US>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64146	18041-10000-43927	6521 S SEPULVEDA BLVD	90045	11	105B165   907	4110001007	C4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.9802	-118.39477	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64147	18041-20000-07143	5659 1/2 E HUNTINGTON DR NORT	90032	14	147A239   344	5309027026	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Expired	11/15/2023 12:00:00 AM	PIN	34.0969759	-118.15687406	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 5.4KVA SYSTEM CONSISTING OF 17 AC MODULES(SPX-X21-335-BLK-D-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64148	16041-20000-37028	14637 W VENTURA BLVD	91403	4	166-5A151  67	2265005003	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM			PC Approved	10/19/2016 12:00:00 AM	ADDRESS	34.15166	-118.45212	ti to an existing commercial office.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy and em lighitng only.  total square footage 2170.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64149	15041-20000-10559	17171 W HALSTED ST	91325	12	201B133   542	2692017019	RA-1-H	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Closed	11/02/2015 12:00:00 AM	ADDRESS	34.24497	-118.50815	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64150	18041-20000-36456	21701 W COHASSET ST	91303	3	186B105  1090	2111003030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	PIN	34.20669438	-118.60181465	pv1install roof mounted pv stsem sized 4.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64151	14041-10000-00017	1167 S CROCKER ST	90021	14	123A211    16	5132011240	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.03329	-118.25166	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 352 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64152	13041-10000-35260	12863 N SAN FERNANDO ROAD	91342	7	222B145   273	2604019029	QCM-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Expired	01/13/2016 12:00:00 AM	ADDRESS	34.3035	-118.46522	Plan check for T24 only, exisiting circuits changing fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64153	19041-10000-11419	111 N HOPE ST	90012	14	133-5A211 168	5161003910	PF-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			Not Ready to Issue	03/29/2019 12:00:00 AM	ADDRESS	34.05807	-118.24862	CONDUIT PERMIT FOR INSTALLATION OF JFB BESS PROJECT 19041-10000-10635(((((((INSTALLING (1) LITIUM BATTERY AND (15) FLOW BATTERIES FOR TOTAL OF 100KW FOR 1 YEAR PILOT PROGRAM. BLD# 19020-10000-00395	N	N	Express Permit	06/10/2024 12:00:00 AM
64154	15041-10000-15578	11405 W VENICE BLVD	90066	11	114B157   387	4234008041	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Apartment			05/20/2015 12:00:00 AM			PC Info Complete	02/24/2016 12:00:00 AM	ADDRESS	34.01065	-118.42175	NEW 14 UNIT APARTMENT 1000 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.FIRE VARIANCE ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64155	14041-20001-34793	20336 W CORALINE CIR	91311	12	207B113   127	2707018009	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			PC Approved	01/08/2015 12:00:00 AM	ADDRESS	34.26358	-118.57675	""" EXPEDITED PER APPLICANTS REQUEST""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.46 KW DC.(32) SUNPOWER SPR E20 MODULES(2) AURORA PVI-5000 INVERTER"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64156	19041-10001-06363	2439 N RIVERSIDE PL	90039	13	148-5A211 150	5440026008	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.10129	-118.25338	SUPP APPLICATION FOR ESS INSTALLATION PART OF PV INSTALLATION. SCOPE INCLUDES SINGLE BATTERY AND PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64157	15041-10000-24712	2430 N ACHILLES DR	90046	4	153B173   462	5569028004	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Expired	08/25/2017 12:00:00 AM	ADDRESS	34.11525	-118.36863	PV1, ROOF MOUNTED SYSTEM. 32 MODULES AND 1- 7.6 INVERTER. TOTAL SIZE 8.42KW. (32) KYOCERA #KU2656ZPA (1) FRONIUS #PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64158	16041-20000-06016	4700 W SUNSET BLVD 1 ST FLOOR	90027	13	147B197   725	5543013001	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.09788	-118.29194	PLAN CHECK FOR POWER AND ENERGY FOR KAISER PERMANENT MEDICAL OFFICE BUILDING 1ST FLOOR. TOTAL AREA 13161 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64159	18041-10000-15222	926 W JAMES M. WOOD BLVD	90015	14	129A207   188	5138005016	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM			PC Info Complete	05/15/2019 12:00:00 AM	ADDRESS	34.04715	-118.2657	FULL PC FOR POWER AND ENERGY FOR A NEW 18-STORY, 247 GUEST ROOMS HOTEL BUILDING. SCOPE INCLUDES A NEW 3000A 277/480V 3PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW TRANSFORMERS, ONE 125HP FIRE PUMP, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 43, 229 SQ. FT.  B#17010-10000-02466	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64160	12041-10000-03491	1042 W DOWNEY WAY 2ND FLOOR	90089	8	117B197     6	5039002034	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	ADDRESS	34.02169	-118.29124	"TENANT IMPROVEMENT OF OFFICE AT 2ND FLOOR OF (E) RESEARCH BUILDING - CONVERT 1250 SF OFFICE SPACE TO TEST LAB; NEW NON BEARING PARTITION WALLS; NEW CEILING PANELS; MILLWORK; FLOOR AND WALL FINISHES. NO RESTROOM UPGRADE.PLAN CHK IS FOR TITLE 24 (PERMIT FEE IS UNDER ""INSPECTION"")"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64161	18041-10000-38644	11150 W SANTA MONICA BLVD 4th floor	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.04704	-118.44563	Energy plan check for an office T.I  located in the 4th floor of a high rise building. Scope includes new lighting and equipment with a total area of 2764-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64162	15041-20000-07609	1515 W 190TH ST Suite 530	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.85852	-118.30531	Title 24 plan check only.  Total area = 2,626 sq. ft.T.I. to existing commercial highrise space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64163	15041-20000-38559	6044 N SUNNYSLOPE AVE	91401	2	177B157   674	2330024016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.18096	-118.42675	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (21) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64164	19041-20000-01438	10722 N BELMAR AVE	91326	12	207B117   194	2708006030	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.26516	-118.55893	PV1.  Install 12.35 kW DC / 11.5 kW AC roof mounted grid tied PV system.  (37) modules with 11.4 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64165	19041-10000-11376	2304 S WESTERN AVE	90732	15	009B193    72	7460004014	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2973.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	33.72367	-118.31178	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64166	11041-10000-01758	5207 S HOOVER ST 2 OF 3	90037	9	108B197   156	5001003002	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Apartment			01/28/2011 12:00:00 AM			Corrections Issued	02/05/2011 12:00:00 AM	ADDRESS	33.9951	-118.28728	SERVICE UPGRADE TO 600 AMP FOR EXISTING 3 SEPARATE  APARTMENT BUILDINGS AND INSTALL A SUBPANEL AND CIRCUITS IN EACH UNIT.   (APP 2 OF 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64167	17041-10000-42131	9600 S SEPULVEDA BLVD	90045	11	093B165   137	4124025049	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	33.94841	-118.39594	REPLAVE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64168	18041-10000-38826	1030 N SWARTHMORE AVE 2-110	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR FIRST TIME TENANT IN  PALASIDES MALL (FAHERTY BRAND). SCOPE INCLUES NEW EQUIPMENT, PANLES,  CIRCUITS AND LIGHTS.TOTAL AFFECTED AREA  1180 SQ.FTB# 18016-10000-32919	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64169	12041-20002-08177	1051 N VISTAGRANDE DR	90272	11	132B121   422	4420025036	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.05606	-118.55074	Changes to approved plan. Plan check only for power. Permit is under 12041-20001-08177.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64170	12041-10000-27646	6701 S CENTER DR WEST	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	33.97907	-118.39369	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS FOR A TENANT IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64171	10041-10002-10217	8180 W MELROSE AVE	90048	5	141B173   468	5528011036	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM			PC Approved	01/06/2011 12:00:00 AM	PIN	34.0834491	-118.36781879	Change the previously approved plan. EPC is for T24. (((((((((((((T-24 lighting plan check for remodeled tenant space.)))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64172	15041-10001-22814	5422 W CARLIN ST #1	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			Reviewed by Supervisor	07/31/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON COMMERCIAL BUILDING.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64173	17041-20000-00042	7514 N LANKERSHIM BLVD	91605	2	186B169   423	2316013003	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.20703	-118.38758	ti to an existing commercial building adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 10188.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64174	17041-30000-17210	2222 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles - Century City - Rancho Park			2677.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	PIN	34.03796157	-118.44031576	Plan check for title 24 only in existing space  T.I. Total area: 1,124 sq ft B# 17016-30000-09925	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64175	13041-10001-07157	3630 W WATT WAY	90089	8	118-5A201  14	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.02062	-118.28738	Changes to approved set of plans. Changes to kitchen area. power only. Changes on plans include all kitchen receptacles to be GFCI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64176	17041-10001-28876	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.21922	-118.44896	05/15/2019CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF BASEMENT DEVICES TO REFLECT FIELD CONDITIONS. _________________________________________NEW FA SYSTEM FOR ADAPT REUSE OF BUILDING. APARTMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64177	14041-20001-33911	8812 N SPARTON AVE	91331	6	195B153   733	2640023008	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2014 12:00:00 AM			PC Approved	12/29/2014 12:00:00 AM	ADDRESS	34.23001	-118.43325	CHANGE IN ROOF LAYOUT. RESTAMP FOR NEW LAYOUT. NO CHANGE IN ELECTRICAL SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64178	14041-20000-25663	12910 N SAN FERNANDO ROAD	91342	7	222B145   153	2501006033	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.30526	-118.46597	TI TO AN EXISTING ONE STORY COMMERCIAL BUILDING.  ADDING LIGHTING TO EXISTING POWER PANELS.  27751 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64179	16041-20000-32916	3551 S TROUSDALE PKWY OFFICE 156	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	34.02066	-118.28531	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 120. IN OOFCE 156.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64180	13041-10000-07657	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			Corrections Issued	03/26/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	PLAN CHECK FOR TITLE 24 OUTDOOR LIGHTING .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64181	17041-10000-24203	1556 N ORANGE GROVE AVE	90046	4	147B177   652	5551020018	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.09968	-118.36034	Plan check for roof mounted PV system. System size - 7.6KVA. System consist of 1 inverter(SE7600A-US), and 28 modules with power optimizers(P300).	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64182	16041-10000-26147	5131 N MAYWOOD AVE	90041	14	162A223    30	5671010022	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	09/03/2016 12:00:00 AM	PIN	34.14015897	-118.21208936	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(36)MODULES-GIGAWATT GW280MB(36)OPTIMERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE7600A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64183	14041-10000-26168	5518 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			09/23/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.06209	-118.34908	TENANT INPROVEMENT IN COMMERCIAL SPACEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64184	14041-20000-19908	23700 W INGOMAR ST	91304	12	189B089   384	2020014039	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.21146	-118.64447	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 201210.75KW PV1 roof-mounted system with (50) YingLi YL250P modules and Enphase M215 micro inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64185	12041-20000-31113	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM			PC Approved	12/28/2012 12:00:00 AM	ADDRESS	34.01871	-118.28174	T.I. to an existing restaurant.  Load is less than 400 amps and occupancy load is less than 99.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64186	16041-10005-38144	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM			PC Approved	02/25/2019 12:00:00 AM	ADDRESS	34.26153	-118.50259	DELTA 5 CHANGES TO AN APPROVED SET. UPDATE VALUES FOR FAULT CURRENT FOR UTILITY, DISCONNECTS AND LOAD CENTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64187	16041-20000-41140	360 S MAPLETON DR	90024	5	138B157    25	4359013024	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Issued	01/10/2017 12:00:00 AM	ADDRESS	34.07629	-118.43071	Upgrade of (E) 600A 120/240V 1ph/3w service to a new 1600A, 120/208V 3ph/4w service for existing SFD and future theater.  New proposed generator backup for complete service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64188	16041-20000-21106	8900 N DE SOTO AVE Bldg 102-Room 101	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check Title 24 only Aerojet Rocketdyne in conference room T.I. existing space BLDG 102 Room 101. Total area: 1,373 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64189	17041-20001-18154	7606 N FALLBROOK AVE #8	91304	12	186B097   194	2013008054	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM			PC Approved	06/20/2017 12:00:00 AM	ADDRESS	34.20847	-118.6232	Revisions to an approved plan.  Change to emergency lighting system and photometric calculations.  (((ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.Building application # 17041-10000-10540)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64190	19041-20000-11150	212 N ARDEN BLVD	90004	4	138B189   623	5515017008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.07504	-118.32584	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM TO EXISTING PV ARRAY FOR EXISTING SFD. SCOPE OF WORK INCLUDES (2) 5KW TESLA POWERWALL SYSTEMS AND A 200A SUB PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64191	14041-10000-16579	11620 W WILSHIRE BLVD 520	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.05021	-118.45963	permit to be pulled at EPC counter only. Plan check for energy only. Suite 520. High rise with emergency lighting. BLDG#14016 70 11904 520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64192	19041-10000-34200	11035 N LEOLANG AVE	91040	7	210B193   576	2552014008	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.2698	-118.3064	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE 7.6KWac/6.5KWdc. SCOPE WORK INCLUDES 20 MODULES (CANDIAN SOLAR CS1H-325MS) WITH OPTIMZERS (SEP320) LEADING TO A CENTRAL INVERTER (SE7600A-US), WITH A BATTERY (LG CHEM RESU 10H), AND A CRITICAL LOADS PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64193	17041-20001-41720	814 N SAN FERNANDO ROAD	90065	1	144A219    36	5453006048	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			PC Approved	01/05/2018 12:00:00 AM	ADDRESS	34.09066	-118.22723	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 126.75 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64194	19041-20000-19433	23329 W OSTRONIC PL	91367	3	171B093   647	2044024020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.16295	-118.63509	PV1.  Install 16.92 kW DC / 15.319 kW CEC-AC roof mounted grid tied PV system.  (47) AC modules.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64195	19041-10000-42192	11960 W VICTORY BLVD	91606	2	180B165   771	2334004023	P-1, RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.18651	-118.39393	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64196	14041-20000-18131	9671 W SOMBRA VALLEY DR	91040	7	204B181   307	2545026005	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Expired	08/10/2016 12:00:00 AM	ADDRESS	34.25229	-118.34278	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.5KW INTERCONNECTED WITH MSP.(26) SUNIVA MODULES OPT270-60(26) M250 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64197	14041-20000-04775	3616 S TROUSDALE PKWY B54A	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.01983	-118.28534	"t24 part 6 energy for 130 sq office space. scope of work < 400A.note: permit fee precalculated under ""inspection"" fee period. The items were per engineer"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64198	18041-20000-42547	9968 N ARLETA AVE	91331	6	201B153    24	2645010017	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.25159	-118.43585	Plan check for a PV1 roof-mounted PV system. System size is 3.15 kWdc/3 kWac and consists of (1) inverter and (9) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64199	17041-10000-12425	3347 W SAN FERNANDO ROAD	90065	13	153B209   103	5458006002	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.11858	-118.24925	PC FOR ADDITION OF PV SYSTEM TO EXISTING INSTALLED PV SYSTEM. THIS IS 30KW ADDITION AND SHALL MEET NEW CODE CYCLE STANDARDS. TOTAL OF 126 MODULES 30KWAC/36KWDC AND CENTRAL INVERTER. CONNECT TO EXISTING PV LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64200	15041-10002-20867	212 N AVENUE 57	90042	1	151-5A229  69	5468033037	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.11097	-118.19401	Changes to an approved set of plans note changes on clouded areas. Changes include a new subpanel, revision to a 2 gang meter and relocation of equipment. (((PV1.  Install 3.27 kW roof-mounted, utility-interactive PV system.  Plan check per applicant request.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64201	15041-30007-14620	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	03-01-2018 Changes to an approved set of plan. Changes include addition of new feeder for 90KVA 400Hz unit equipment. Changes under delta 42 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64202	18041-20000-24178	11470 W COLLINS ST	91601	2	174B169   601	2338028007	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Apartment			06/28/2018 12:00:00 AM			PC Info Complete	06/24/2020 12:00:00 AM	ADDRESS	34.17383	-118.38134	800A 240/120V 3ph-4w service, distribution, power, and lighting for new construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64203	19041-10000-49596	10403 W VALLEY SPRING LANE	91602	4	165B177   796	2424015018	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	34.14687	-118.35734	$0 Permit fee due to AB1414 *** PV1. NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.0696KWdc / 14.106KWac.(48)MODULES-327 W MODULES & (48)MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64204	19041-20000-19978	14731-14735 W CALIFA ST	91411	4	177A149   147	2244009026	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	10/07/2022 12:00:00 AM	ADDRESS	34.17771	-118.45439	1200A 480Y/277V service upgrade to (E) multi-tenant commercial building and associated distribution. Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64205	12041-20000-14512	10301 W PICO BLVD	90064	5	129B161   350	4315014031	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.04831	-118.41392	T.I. to existing building on partial of 1st floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64206	12041-10000-15137	1680 N VINE ST	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	Plan check for power. No lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64207	14041-10000-03895	5530 N RESEDA BLVD	91356	3	174B125   516	2160010028	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.17063	-118.5358	New fire alarm system with audio/visual notification in a single-story commercial retail building (HomeGoods).  Type V-B construction, fully sprinklered.  13 devices coordinated by Fire-Lite MS-9200UDLS FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64208	15041-10000-26736	8521 N FALLBROOK AVE STE 360	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.22368	-118.62797	PC FOR ENERGY ONLY. T-24 TO A COMMERCIAL BLDG (WELLS FARGO) (3) STORY HIGH. THE SCOPE OF WORK IS BEING DONE ON THIRD FLOOR, SUITE 360. . TOTAL SQ FT = 11035.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64209	18041-20000-42846	4500 N DEANWOOD DR	91364	3	165B113    56	2174028019	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.15146	-118.5762	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64210	14041-10000-17603	10250 W SANTA MONICA BLVD # 208	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	PIN	34.0586034	-118.41904766	PC FOR ENERGY ONLY. EXISTING BUILDING AS OFFICE. TI, TOTAL AREA 4182 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64211	15041-20002-28592	8445 N JAMIESON AVE	91325	12	192B129   170	2787011020	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2015 12:00:00 AM	09/11/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.22393	-118.52177	$0.00 fee due to senate bill for solar projects.  Original plan check description and fee list had incorrect number of modules (plans originally showed 32 modules but only 27 were counted).  The remaining 5 modules are included on supplemental application.PV1. Install roof mounted PV system sized 8.8 kW. Interconnected with main service panel.(32) SPR 327NE Modules(1) SMA SUNNYBOY SB3800 TL(1) SMA SUNNYBOY SB5000 TL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64212	16041-20000-41469	1447 N MARTEL AVE SLS#2	90046		147B181  1153	5550021013							Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Plans on Hold	12/02/2016 12:00:00 AM	ADDRESS	34.09728	-118.35102	New 4-story single family dwelling with subterranean attached garage.  Small lot subdivision.  Collective service for (6) new SFDs on same lot.  Plan check for power and energy.  Service equipment, house panel, and energy fees charged on unit #1.  Building permit filed under 16010-10000-02540 et al	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64213	13041-20000-19058	970 W 190TH ST SUITE 650	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	33.85812	-118.29302	T24 ENERGY ONLY FOR EXISTING OFFICES. NEW LIGHTING AND EMERGENCY CIRCUIT. TOTAL AREA 4886 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64214	14041-20000-20000	10939 N ELDORA AVE	91040	7	207B189    31	2551021024	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.2681	-118.31503	PV1.  Install 4.75 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64215	13041-10000-20697	515 S FLOWER ST SUITE 2850	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/12/2013 12:00:00 AM	ADDRESS	34.05134	-118.25661	TITLE-24 FOR CORRIDOR ON EXISTING LIGHTING. THE EMERGENCY LIGHTING WILL BE FED VIA EXISTING EMERGENCY CKT & GENERATOR. WORK IS DONE ON 28TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64216	13041-10000-36107	10631 W VINEDALE ST	91352	7	195B177   334	2404006025	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley		1021.07	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.22878	-118.36286	NEW FA FOR R2.1 ASSISTED LIVING FACILITY 1 STORY. NEXT to a oshpd HOSPITAL. 304 devices, 1 panel and 9 other comm panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64217	19041-10000-48899	18317 W STRATHERN ST	91335	12	189B125   350	2102006013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	34.21576	-118.53234	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR A SERVICE OF  225 AMPS. INSTALLATION INCLUDES 12 MODULES (POWERXT 360R-PD, 12 OPTIMIZERS (P400), 2 PANELS OF 125 AMPS 1 CENTRAL INVERTER (SE5000H), AND 1 POWERWALL. SYSTEM SIZE: 4.32 KW DC; 5 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64218	14041-20000-19332	10527 N SEPULVEDA BLVD	91345	7	207B145   562	2649013005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2014 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Expired	08/19/2016 12:00:00 AM	ADDRESS	34.26179	-118.46771	Standard Plan: 8.16KW PV1 roof-mounted system with one Power One PVI-6000-OUTD transformerless inverter and (36) Trina Solar TSM255 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64219	17041-20000-43279	229 N BURLINGTON AVE #3	90026	13	136-5A207 286	5159006009	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM			Reviewed by Supervisor	01/12/2018 12:00:00 AM	ADDRESS	34.06717	-118.26626	plan check for power only.NEW 4 STORY SINGLE FAMILY DWELLING W/ ATTACHED GARAGE. (PART OF NEW SMALL LOT SUBDIVISION). 3 of 6 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64220	19041-10000-01876	2580 N CAHUENGA BLVD	90068	4	153A185    16	5577025904	[Q]PF-1XL-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.11385	-118.3354	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64221	15041-10000-17205	4180 W WILSHIRE BLVD	90010	4	132B189    59	5092001022	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.06148	-118.31872	install new fa system for 5-story 29 units apartment building. 92 devices 1 annonciator and one fa panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64222	10041-20000-18168	7250 W FRANKLIN AVE 1st floor	90046	4	147B181    21	5548025***	R3-1	Central	Hollywood	Hollywood Hills West	YES	1899.01, 1941.00	Electrical	Electrical	Apartment			09/14/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	09/21/2011 12:00:00 AM	ADDRESS	34.10329	-118.34724	Install general lighting in first floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64223	10041-10000-22263	229 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			11/12/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	04/19/2011 12:00:00 AM	ADDRESS	34.04926	-118.22589	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64224	16041-20000-00532	1229 N MCCADDEN PL	90038	4	144B185   243	5532005040	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.09365	-118.33758	INSTALLATION OFA NEW FIRE ALARM SYSTEM. 1 FACP AND 48 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64225	17041-20001-09396	10362 N PETIT AVE	91344	12	204B137    92	2684005008	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2017 12:00:00 AM			Reviewed by Supervisor	04/05/2017 12:00:00 AM	ADDRESS	34.25931	-118.49781	expedite.pv1install roof mounted pv system sized 6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64226	14041-20000-05441	12123 N LOUISE AVE	91344	12	216B129    69	2606027060	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.29166	-118.51323	pv1 single family dwelling. total system size 5.1 kw ac using enphase m215 microinverter. using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64227	18041-10000-38547	6414 S MCKINLEY AVE	90001	9	105B205  1037	6007015027	M3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Closed	11/18/2021 12:00:00 AM	ADDRESS	33.98126	-118.26127	Pc for  title-24, Energy only.Socpe includes new lights and receptacles. Total affected area is 9380 sq.ft.building app # 16016-10000-30189	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64228	19041-20000-29492	14758 W OTSEGO ST	91403	4	171A149   174	2263031001	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	08/10/2019 12:00:00 AM	ADDRESS	34.16291	-118.45501	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM. SYSTEM SIZE IS 4.44KW DC/3.78 KW AC. SCOPE OF WORK CONSISTS OF (12) SUNPOWER SPR-X22-370-E-AC PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64229	17041-10004-44218			10	126B193   367	5074018004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM			PC Approved	09/18/2018 12:00:00 AM	PIN	34.04308338	-118.30618119	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES RELOCATION OF ELECTRICAL EQUIPMENT PER FIELD INSTALL AND ADDITIONAL AC DISCONNECT PER DWP REQUEST. THIS IS PLANCHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64230	18041-20001-35470	11415 N MONTALCINO WAY	91326	12	213B109   411	2701068022	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.27894	-118.58674	supplemental plan check only for changes to approved set. change from partial energy storage system to whole house energy storage system. minor changes to single line diagram, clouded changes only*original*Plan check for batter back up system installed in to existing PV roof mounted. installed 3 Tesla PowerWalll 2.0 13.5kWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64231	11041-20000-25045	21860 W BURBANK BLVD	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.17198	-118.60379	T24 lighting plan check for a two floor office building.  Existing permit 11041-90000-23937.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64232	16041-10000-28827	700 W 9TH ST	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.04579	-118.2618	Install (N) Fire alarm system on (E) live-work building.  689 units + 8 commercial condominium.    (10) Panels       (1152) devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64233	18041-10000-07053	2323 W 4TH ST	90057	1	135A203   225	5154035030	R3-1	Central	Westlake	MacArthur Park	YES	2088.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.06373	-118.27574	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 4950 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64234	18041-20000-07768	20652 W CHESTNUT CIR (#337)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.29346	-118.58453	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64235	17041-10000-17841	11844 N GLENOAKS BLVD	91340	7	216B157    60	2524001900	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			05/30/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.28512	-118.42349	Plan check for power only. Service upgrade to 800 Amps 120/240V 3 phase 4 wire. To a 1 story light manufacturing building to youth center. New equipment as noted by delta 1 clouds.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64236	15041-20000-07581	10031 N TOPEKA DR	91324	12	204B121   494	2729004024	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.25286	-118.54595	Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  Two inverter system with 40 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64237	11041-10000-05869	5700 W WILSHIRE BLVD Suite #400	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	04/22/2011 12:00:00 AM	ADDRESS	34.06218	-118.35303	TI IN AN EXISTING OFFICE AREA ON THE 4th FLOOR IN SUITE #400. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64238	15041-10000-27184	445 W ELBERON AVE	90731	15	021B197   854	7448024009	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	33.75006	-118.28836	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.6KW INTERCONNETED WITH MSP.STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64239	19041-10000-52464	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.03145	-118.41085	"REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFITS KITS.INDOOR ""BARON SCHOOL BDG"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64240	12041-20000-00611	1340 W MARYLAND ST	90017	1	132A207   167	5152002033	CW	Central	Westlake	Westlake North		2092.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Finaled	12/21/2012 12:00:00 AM	ADDRESS	34.05621	-118.26227	Photovoltaic system on roof of apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64241	17041-20000-21937	4405 N MEDLEY PL	91316	5	165B129   136	2184036023	RA-1	South Valley	Encino - Tarzana	Encino	Yes	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.15046	-118.52432	PV1.  Install roof mounted grid tied PV system sized 15.2 kW interconnected with MSP.$0 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64242	14041-10000-27642	2171 W FLORENCE AVE	90047	8	102B189  1308	6016032024	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	33.97475	-118.31755	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CONVENIENCE STORE. NEWLY CONNECTED LOAD <400 AMPS. 1890 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64243	13041-10000-24726	1870 N BURNELL DR	90065	1	148-5A217  58	5455006021	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.10292	-118.23147	PV1.  Instal 2.94 kW DC roof-mounted solar array of 12 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64244	15041-10000-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR POWER AND ENERGY. NEW DISTRIBUTION EQUIPMENT FOR FUTURE TENANTS. MALL IS GUTTING AND RENOVATING 8TH FLOOR FOOD HALL. ASSOCIATED HOUSE LOADS AND EQUIPMENT INSTALLED AT THIS TIME. PC FOR POWER AND ENERGY. PC FOR AREAS DESCRIBED AS FH - FOOD HALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64245	11041-20000-27472	9207 N OAKDALE AVE	91311	12	198B113   133	2761001084	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/28/2011 12:00:00 AM			PC Approved	12/28/2011 12:00:00 AM	ADDRESS	34.23815	-118.56707	Existing office space.  Relocating existing light fixtures.  Plan check is for energy only.  <<<<T.I.  INTERIOR NON STRUCTURAL REMODEL TO (E) OFFICE (5969 SF) ON THE 2ND FLOOR OF (E) 2 STORY OFFICE.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64246	19041-20000-00996	14240 W MCCORMICK ST	91401	4	171B153   416	2248021027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.16565	-118.44354	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (2) battery back-up units onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64247	16041-10000-32613	1601 E OLYMPIC BLVD #401	90021	14	123A213    10	5146009006	M2-2D, M3-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.02923	-118.24056	TITLE 24 TO EXISTING LOWRISE COMMERCIAL BUILDING.TOTAL SQ. FT. 4550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64248	18041-20000-00027	4601 N NOMAD DR	91364	3	168B113   393	2175018028	RE40-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.15534	-118.56877	permit fee $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 11.7kw interconnected wtih msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64249	14041-20001-27359	320 S HAMPTON DR	90291	11	111B141   717	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM			PC Info Complete	06/02/2015 12:00:00 AM	ADDRESS	33.99612	-118.47637	Changes to approved set.  Addition of a new transformer and 3 panels.  Relocation of 5 panels and 1 inverter.*****Previous Work Description*****TI TO AN EXISTING COMMERCIAL ONE STORY BUILDING.  ADDING PANELS, MOTORS, CIRCUITS TO THE EXISTING SERVICE.PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64250	16041-20001-21094	11606 N DE CELIS PL	91344	12	213B137   387	2610010015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM			PC Approved	06/25/2016 12:00:00 AM	ADDRESS	34.28127	-118.49588	Expedite per applicant request((((Plan check for PV roof mounted system. System size: 5.56kW with 17 AC Modules(ACM) connected to sub-panel))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64251	14041-20000-33418	12972 W SUNBURST ST	91331	7	201B161   137	2623029011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.25098	-118.41551	"Roof mounted PV system with total size 3.9KW.Note: solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.""COMPLY WITH DEPARTMENT ORDER effective date11/12/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64252	16041-10000-04369	306 E 48TH ST	90011	9	111A205   144	5109009056	RD1.5-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	33.99913	-118.27022	PV1, ROOF MOUNTED SYSTEM USING CENTRAL INVERTERS. (17) MODULES AND (1) 4.2KW INVERTER. TOTAL SYSTEM SIZE 4.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64253	12041-10000-05771	7501 N SAUSALITO AVE	91307	3	186B101   397	2022021020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.20649	-118.61597	New rooftop photovoltaic system for an existing sfr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64254	12041-10000-19851	905 E 8TH ST	90021	14	124-5A213  77	5146029039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	02/14/2013 12:00:00 AM		Permit Finaled	07/01/2014 12:00:00 AM	ADDRESS	34.03645	-118.24647	CONVERT 2-STORY WAREHOUSE TO OFFICE; CHANGE FRONT ELEVATION AND NEW INTERIOR WALL;SINGLE TENATPLANS DESIGNED WITH INTENT FOR FUTURE SERVICE UPGRADE SEE # 12041-10000-02674	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64255	16041-20001-09165	925 N LA BREA AVE	90046	5	144B181   708	5531016020	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM			PC Approved	08/17/2016 12:00:00 AM	ADDRESS	34.08803	-118.34436	CHANGES TO AN APPROVED SET OF PLANS.  EXIT SIGNS TO PROVIDE TWO CIRCITS AND PROVIDE INVERTER DETAIL.  CHANGES NOTED DELTA 3. THIS IS PLAN CHECK ONLY. FULL PC FOR POWER AND ENERGY. TI FOR A NEW DAY SPA ON THE GROUND FLOOR OF AN EXISTING MIXED USED COMMERCIAL BUILDING. SCOPE INCLUDEW NEW LIGHTING, TWO NEW 600A DISTRIBUTION BOARDS, AND SEVEN 225A SUBPANELS. TOTAL AFFECTED AREA IS 16,620 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64256	16041-10001-21390	4744 N HASKELL AVE	91436	5	168B141   579	2261029003	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.15645	-118.47467	EXPEDITED FEES ((PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH OPTIMIZERS. (51) MODULES LG320N1C-G4 AND (51) OPTIMIZERS SOLAR EDGE PV (2) 7.6KW SOLAR EDGE INVERTERS. TOTAL SYSTEM SIZE IS 15.2KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64257	18041-20000-00329	1292 S DEVON AVE 1-7	90024	5	135B157   320	4327014012	[Q]RD1.5-1XL	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			01/04/2018 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.06489	-118.42619	service upgrade 600 amps to an existing apartment building.  plan checkfor power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64258	10041-20000-18144	601 S FIGUEROA ST 42nd Floor	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			09/14/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check T-24 energy (general/emergency) lighting on the 42nd floor office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64259	18041-10000-21977	2049 S CENTURY PARK EAST Suite#1940	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI IN AN EXISTING OFFICE AREA IN SUITE #1940 ON THE 19TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64260	15041-10000-12396	5161 N LANKERSHIM BLVD 3rd Floor	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.16452	-118.37469	Energy plan check for an office (Aspect)  T.I located at the 3rd floor of a 4-story, commercial building; scope includes installation of new lighting and receptacles. Total area is 17778-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64261	10041-10001-01971	10201 W PICO BLVD	90035	5	129B161  1442	4315019012	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM			PC Approved	09/09/2010 12:00:00 AM	PIN	34.05182951	-118.41257696	DELTA 2 CHANGES TO APPROVED PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64262	11041-20000-22811	3201 S LA CIENEGA BLVD 121A	90016	10	123B173  1610	4205035013	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	01/05/2012 12:00:00 AM	ADDRESS	34.02965	-118.37211	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64263	14041-10000-08137	133 W AVENUE 45	90065	1	147A223   187	5467009001	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1851.00	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.09657	-118.20819	T24 FOR EXISTING GROCERY STORE. RELOCATING LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64264	18041-20001-34502	10419 W DUNLEER DR	90064	5	123B161    22	4318021023	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM			PC Approved	09/27/2018 12:00:00 AM	ADDRESS	34.03702	-118.41235	09-27-2018 Change to an approved set, changes include modify PV module layou on roof . Changes has been clouded.Plan check only.Fees$ 0.00 due to California Senate Bill 1222 and Assembly Bill 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64265	18041-10001-22794	1261 S STONER AVE 1-8	90025	11	129B145   887	4263008009	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			Reviewed by Supervisor	07/26/2018 12:00:00 AM	ADDRESS	34.04711	-118.46065	PLAN CHECK FOR BATTERY BACKUP SYSTEM INCLUDING (4) TESLA POWERWALLS (13.2KWH) PV SYSTEM UNDER ORIGINAL PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64266	17041-10000-19401	8300 N TOPANGA CANYON BLVD	91304	3	192B101   559	2779037026	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.21991	-118.60578	NEW RESTAURANT WITH DRIVE-THRU. NEW 1200A SERVICE. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64267	19041-20000-31643	14612 W ISLA VISTA DR	91402	6	201B149   888	2650019061	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.2474	-118.45093	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON A NEW SFD. SYSTEM SIZE IS 3.15KW DC/2.835 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64268	11041-20000-05650	960 E 3RD ST	90013	9	127-5A217  90	5163016011	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	ADDRESS	34.04578	-118.23289	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR INTERIOR RENOVATION IN AN EXISTING, TWO STORY, PROFESSIONAL SCHOOL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64269	16041-20000-16708	3400 W SUNSET BLVD	90026	13	144A203   344	5427026021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Apartment			05/23/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.08744	-118.27608	Plan check for New apartment 35 units mixed use building. Service 2000A.  Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64270	16041-10003-27380	877 S FRANCISCO ST	90017	14	129A207   122	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.04791	-118.26383	PC FOR CHANGES TO APPROVED SET.  (FOR OUTDOOR TITLE 24)SCOPE INCULDES ADDITION TO GROUND FLOOR (OUTDOORS LIGHTS) LEVEL 3,5,21OUTDOORS WALKWAY AND   9TH LEVEL   (OUTDOORS).INCLUDING NEW LIGHTING CIRCUITS  (20 277V AND 1 120V) TOTAL AFFECTED AREA 46336 SQ.FT PLAN CHECK FOR POWER AND ENERGY FOR BLD R2, A  HIGH RISE MIX USE, RETAIL, PARKING, AND RESIDENTIAL BUILDINGS. R-2, RESIDENTIAL  NEW TENANT SPACES FROM FLOORS 5 THROUGH 42 INCLUDING 514 NEW PANELS(14 TYP UNITS) AND ONE 50 HP POWER MOTOR CONNECTED TO EXISTING. METER SWITCHGEAR UPGRADE TO 2000 AMP SERVICES.ORIGINAL CORE/SHELL APPLICATION COVERS BUILDING R2 AND R3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64271	17041-30000-02686	3743 S MIDVALE AVE 1-13	90034	5	117B161   645	4252025007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.01737	-118.41181	Installation of fire alarm system in new 4 story 12 unit apartment building.  Total system size = 77 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64272	15041-10000-19625	4455 W LOS FELIZ BLVD	90027	4	153A201   236	5588026***	R3-1XL	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Apartment			06/23/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.11217	-118.28709	INSTALLATION OF 230KW 480V OPTIONAL STANDBY GENERATOR, ASSOCIATED STANDBY DIST. ELEMENTS.((NO EMERGENCY LIVE SAFETY LOADS PER APPLICANT))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64273	12041-10000-16851	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			PC Approved	07/19/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT OF (E) RETAIL SPACE #1084F.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64274	13041-10000-14886	1055 W 7TH ST	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/14/2013 12:00:00 AM	ADDRESS	34.0507	-118.26334	Office TI in highrise building, suite 3150.  New lighting and receptacles.  Newly connected load < 400A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64275	12041-10000-18244	6513 W LA MIRADA AVE	90038	4	144B185  1328	5533002063	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2012 12:00:00 AM			Corrections Issued	08/03/2012 12:00:00 AM	ADDRESS	34.09364	-118.33153	Plan check for roof mounted 1.5KW photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64276	13041-20000-35104	3415 S SEPULVEDA BLVD SUITE 400	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	ADDRESS	34.02055	-118.42347	TI FOR OFFICE SPACE - SUITE 400.  PLAN CHECK FOR TITLE 24 FOR CHANGES TO LIGHTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64277	14041-20001-16602	3411 E ESTRADA ST	90023	14	120A225   371	5190017037	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM			PC Approved	07/10/2014 12:00:00 AM	ADDRESS	34.02081	-118.20481	EXPEDITE PER APPLICANT REQUEST[[[PV1Install a roof mounted solar array on a SFD. System size: 6kW(1) PowerOne PVI-6000-OUTD-US transformerless inverter(20) SunPower 327W pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64278	19041-20000-14458	12906 W VENICE BLVD	90066	11	111B153   852	4236012003	[Q]C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	33.99948	-118.44138	ti to an existing restaurant.  adding new lighting new controls to new panel. newly connected load < 400 amps plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64279	18041-10000-25752	10250 W SANTA MONICA BLVD #2380	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM			PC Info Complete	08/01/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	FIRST TIME TENANT IN A RETAIL SPACE WITHIN WESTFIELD CENTURY CITY MALL. PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT 18016-10000-21989	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64280	14041-10002-08051	412 N FAIRFAX AVE	90036	5	141B177  1435	5527030018	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.07866	-118.36128	new lighting apply to approved set. plan check only, area also extended to 1545 SQ feet.(((TI in an existing pizza store. EPC is for T24 and emergency lights. (1st time tenant [see 14041-10-07618] - power done under supplemental. fees are under inspection)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64281	16041-10000-34237	3131 S HOOVER ST Bldg #9A	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.02611	-118.28472	Full PC for new commercial space (Target) under new mixed use building. Adding new distribuition board rated at 800 Amps. New lighting and power. Totalsqft = 22436.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64282	17041-10000-25740	4151 W PROSPECT AVE BLDG G	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	"PC FOR POWER RPLACING TWO SWITCH BOARDS 800 AND 1600 AMPS  240V WORK DONE IN  BUILDING  ""G""  STAGES ONE AND TWOSCOPE INCLUDES  REPLACING EQUIPMENT AND INSTALLING NEW CIRCUITS"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64283	17041-10000-33559	4551 S GLENCOE AVE Suite 340	90292	11	105B153   615	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC FOR (E) OFFICE TI ON THE 3RD FLOOR FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT, LIGHT AND RECEPTACLES.TOTAL AFFECTED AREA  2935 SQ.FT.B# 17016-10000-25562	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64284	14041-10000-11761	6033 S CENTRAL AVE	90001	9	105B209    92	6007007022	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	33.98492	-118.25673	PV2 ROOF MOUNTED 3PHASE SYSTEM. TOTAL SYSTEM SIZE 44.4KWAC.No fee per senate solar bill	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64285	19041-20001-30818	10400 N NEVADA AVE	91311	12	204B101    58	2723017106	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM			PC Approved	10/08/2019 12:00:00 AM	ADDRESS	34.25925	-118.60927	09-27-2019 Changes to an approved set of plan, Changes include addtion of AC disconnect at inverter. Plan check only,Fees $ 0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64286	13041-10000-21902	6333 W 3RD ST #706	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.07157	-118.36014	FULL PLAN CHECK FOR POWER AND ENERGY; TI FOR A RESTAURANT. OCCUPANT LOAD IS > 100. 3582 SF (INDOOR & OUTDOOR).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64287	19041-20000-01712	12543 N WOODLEY AVE	91344	12	219B137    25	2609013016	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.2994	-118.49664	PV1.  Install 13.53 kW DC / 12.636 kW CEC-AC roof mounted grid tied PV system.  (41) modules with (2) 6 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64288	18041-20001-00853	20332 W VIA BOTTICELLI	91326	12	219B113   257	2701059049	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.29746	-118.57668	expeditepv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64289	14041-10000-01284	7645 W DAY ST 1-4	91042	7	204A197   186	2558034033	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Apartment			01/15/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.25464	-118.29945	"PV2 45KWdc. 208V. xmfrLESS/Ungnd. 2 story. Roofmount. [(2) inverters: {TRIO-27.6-TL}]. [(150)modules: {renesola 156 series}]    "" per senate bill no 1222, fee cap reached on original application, thus fee is 0 $"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64290	19041-10000-48521	15418 W HAMNER DR	90077	5	156B145    86	4378015017	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM			Reviewed by Supervisor	12/04/2019 12:00:00 AM	ADDRESS	34.12552	-118.46293	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 7.56KWdc (7.56KWac) USING 24 QP315 MODULES & DELTA SOLIVIA 7.6TL CENTRAL INVERTER. ESS TESLA POWERWALL.CONNECTED TO A 200 AMP EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64291	10041-20000-14255	4411 S 11TH AVE 1-143	90043	8	111B185   119	5013022030	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM			PC Info Complete	09/14/2010 12:00:00 AM	ADDRESS	34.00327	-118.32948	Replace and upgrade fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64292	19041-20000-46677	12010 N LOUISE AVE	91344	12	216B129   137	2606028027	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.28989	-118.51262	PV1.  Install 13.6 kW DC / 11.87 kW AC roof mounted PV sykstem.  (34) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64293	10041-20000-07431	17145 W VENTURA BLVD	91316	5	171B133   703	2258012025	(Q)P-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Expired	09/13/2012 12:00:00 AM	ADDRESS	34.16066	-118.50709	Plan check T-24 Energy (general/emergency) lighting for a take-out Frozen Yogurt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64294	18041-10000-21204	700 W 7TH ST #S100 &-#U100	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.04797	-118.25815	"PC FOR POWER AND ENERGY FOR RETAIL TI  FOR ""UNIQLO"" STORE. TOTAL CONNECTED LOAD >= 400A TOTAL AFFECTED AREA 15683SCOPE INCLUDES NEW PANELS EQUIPMENT LIGHTS AND CIRCUITS. USING PREFORMANCE METHOD FOR ENERGYB#18016-10000-15811"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64295	16041-20001-13594	5415 N SEPULVEDA BLVD	91411	4	172-5A145  20	2250001021	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Apartment			12/08/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.16888	-118.4664	Revisions to approved set.  Changes made to reflect (E) field conditions.$0 submittal fee is due to State Senate Bill SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64296	19041-20000-51323	21700 W OXNARD ST Ste. 530	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.17901	-118.60179	PLAN CHECK FOR TITLE-24 ADD NEW LIGHTS AND EQUIPMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64297	12041-10000-26574	17240 W SATICOY ST	91406	6	186B133   239	2203017044	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			11/06/2012 12:00:00 AM			PC Approved	11/06/2012 12:00:00 AM	ADDRESS	34.20827	-118.50863	TI in an existing El Polo Loco restaurant. EPC is for T24. Emergency lights are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64298	19041-10000-42829	1430 E 43RD PL	90011	9	114A211   441	5116007011	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	03/05/2021 12:00:00 AM	ADDRESS	34.00482	-118.24908	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.40KWdc / 3.00KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64299	17041-10000-25817	1691 W ADAMS BLVD	90007	8	123B197   818	5054004031	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.03288	-118.29995	FULL PC FOR POWER AND ENERGY FOR A RETAIL AND GAS STATION SPACE. SCOPE INCLUDES A NEW 600A 120/240 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 16007 SQ. FT.  B#17010-10000-01332	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64300	15041-20000-28410	20732 W QUEDO DR	91364	3	169-5A109  80	2166046004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.15918	-118.58549	Plan check for PV roof mounted system. System size: 10kW with 44 modules and 2 inverters (5.0kW and 5.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64301	18041-10000-18961	2324 S SAWTELLE BLVD	90064	11	123B153   145	4260021006	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Issued	05/22/2018 12:00:00 AM	ADDRESS	34.03617	-118.43931	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR INDOOR USE. TOTAL AFFECTED AREA IS 4900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64302	11041-10001-09825	109 N FAIRFAX AVE	90048	5	138B177   554	5511001007	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM			PC Approved	06/06/2011 12:00:00 AM	PIN	34.07471502	-118.36175869	T24 lighting plan check for remodeled restaurant.  <<<<<<<<<<<<<MODIFICATION OF LIGHTING FOR EXISTING T-24.  OTC, PLAN CHECK ONLY.  EXISTING PERMIT UNDER ORIGINAL APPLICATION>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64303	16041-20000-44976	15821 W VENTURA BLVD 6th Floor	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	6th floor corridor TI for (E) commercial highrise building. Plan check for energy.  New lights on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64304	13041-20000-13695	3601 S WATT WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/28/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.02113	-118.28752	13041-20000-13695Replacement of outdoor street lighting on USC Campus downtown.  Site is in a Methane Zone, conduit seals and trench dams are required.   Plan check for Energy and Methane.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64305	17041-10000-29236	19206 W INGOMAR ST	91335	3	189B117   866	2104010018	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.21189	-118.55165	PC FOR PV SYSTEM USING SUNPOWER AC MODULES. TOTAL OF 32 MODULES IN TOTAL. SYSTEM SIZE RATED 10.7KW	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64306	16041-10000-21828												Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM			Verifications in Progress	05/28/2014 12:00:00 AM					N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64307	11041-20000-13479	848 N ALTA VISTA BLVD	90046	5	141B181    31	5525002027	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			06/29/2011 12:00:00 AM	06/29/2011 12:00:00 AM		Permit Finaled	12/08/2011 12:00:00 AM	ADDRESS	34.08664	-118.34731	energy plan check preschool	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64308	16041-10001-35094	21224 W PROVIDENCIA ST	91364	3	168B105   290	2167011036	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM			PC Approved	04/28/2017 12:00:00 AM	ADDRESS	34.15875	-118.59425	Changes to approved setRelocating Ac combiner box, AC disconnect and MSPROOFTOP MOUNTED PVPV1 SFD TOTAL SYSTEM SIZE 11.2KWdc / 10.0KWac USING 40 MODULES IN TOTAL. USING MICROINVERTER SYSTEM ENPHSE M250.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64309	11041-10000-20608	1309 E 7TH ST	90021	14	124-5A215  21	5147035001	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM	09/30/2011 12:00:00 AM		Permit Finaled	11/02/2011 12:00:00 AM	ADDRESS	34.03667	-118.24074	T.I. to an existing office building on the 1st floor.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64310	10041-10005-20309	5200 W WILSHIRE BLVD	90036	4	132B181    30	5507024010	[T][Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			05/01/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	34.06194	-118.3435	REVISIONS TO APPROVED SET OF PLANS; LIST OF CHANGES ARE ATTACHED TO SUBMITTAL APPLICATION (FY)NEW MIXED USE APT (478 UNITS) 6 stories	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64311	12041-10000-07286	1066 N CARRARA PL	90049	11	141B137   218	4493018046	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	06/15/2012 12:00:00 AM	ADDRESS	34.07909	-118.49138	Plan check for new 11.52KW roof mounted photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64312	16041-20000-00841	5436 N PENFIELD AVE	91364	3	171B113    14	2164003022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	02/24/2016 12:00:00 AM	ADDRESS	34.16918	-118.56831	Plan check for a PV1 roof-mounted PV system. System is a 3.5 kWac addition onto an existing 2.2 kWac system for a total system of 5.7 kWac. System addition consists of (14) modules, (14) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64313	16041-20000-35932	8900 N DE SOTO AVE	91304	3	195B109   476	2780001057	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.23162	-118.58832	ti  to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 1500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64314	13041-10000-02213	24911 S WESTERN AVE	90717	15	039B193   649	7372017031	[Q]C2-1VL, [Q]P-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	33.79838	-118.30784	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT OF EXISTING ELECTRICAL LIGHTING AND POWER FOR BUILDOUT. NEW CONNECTED LOAD 868.08 AMPS, 26082 SQ FT. METHANE Zone (no underground work per applicant). separate fire alarm variance filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64315	17041-10000-39557	1901 S AVENUE OF THE STARS 20TH FLOOR	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.05949	-118.41705	PC for T24 only for new lights in office space. New installed load is under 400A. Installing new receptacles and loads. B#17016-10000-28708	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64316	14041-20000-21913	3415 S SEPULVEDA BLVD 7th flr	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM			PC Approved	08/13/2014 12:00:00 AM	ADDRESS	34.02055	-118.42347	Plan check for title 24 only on 7th floor of a commercial building. Total working area is 4570 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64317	18041-20000-06692	11218 W EMELITA ST	91601	2	174B173   178	2337017900	RD2-1	South Valley	North Hollywood - Valley Village	NoHo		1242.03	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.1766	-118.37538	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64318	18041-10000-40396	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007927	A1-1XL-H	Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.1504	-118.32742	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES ADDING NEW ROADWAY & MOSAIC LIGHTING FOR A COMMERCIAL SPACE. TOTAL AFFECTED AREA IS 103390 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64319	13041-10000-03415	3580 W WILSHIRE BLVD	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	03/13/2013 12:00:00 AM		Issued	03/13/2013 12:00:00 AM	ADDRESS	34.06156	-118.3028	"PLAN CHECK FOR FIRE ALARM SYSTEM. REPLACING FIRE ALARM CONTROL PANEL AND INITIATING  DEVICES. NOTIFICATION DEVICES EXISTING TO REMAIN. EXISTING HIGH RISE BUILDING. BUILDING FULLY SPRINKLERED.  ""COMPLY WITH DEPARTMENT ORDER effective date12/06/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64320	18041-10000-47666	21425 W DEVONSHIRE ST	91311	12	204B105   860	2722007052	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.2574	-118.5981	DESIGN BUILT, PLAN CHECK FOR TITLE 24 ONLY T.I TO ART SCHOOL. SCOPE INCLUDES 1930 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64321	15041-10000-35595	1012 W MIRAFLORES AVE	90731	15	021B197   479	1226004002	R1-1XL	Harbor			Y	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Expired	10/26/2017 12:00:00 AM	ADDRESS	33.75297	-118.29901	PV1, INSTALL 5.3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64322	13041-10000-33124	4760 E VALLEY BLVD	90032	14	135A233   155	5223001004	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.06457	-118.18075	TITLE 24 PART 6 ENERGY; SCOPE OF WORK IS FOR REMOVING (E) HID FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. 12 TOTAL UNITS. PROJECTED AREA IS AROUND 5004 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64323	13041-20000-04667	636 N LA BREA AVE	90036	5	141B181   761	5525017004	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.08285	-118.34386	New  3-story private school.  Type III-A Construction <Fire sprinklers thru-out>  Site is in a METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64324	14041-10000-08584	1623-1623 1/2 N CAHUENGA BLVD	90028	13	148-5A187 249	5546007012	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.10045	-118.32968	Plan check for power and energy. 2 story. Scope of work (performance area 2) is not a place of assembly. BLDG#: 14016-10-03570. CHANGE OF USE FROM RESTAURANT TO NIGHT CLUB. CONVERT STORAGE AREA TO PERFORMANCE AREA; ADDITIONAL RESTROOMS; ADDITIONAL BAR AREA; CHANGE OCCUPANCY; REMOVE KITCHEN AREA; (N) NON BEARING PARTITION WALLS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64325	14041-10000-16918	9495 N SAN FERNANDO ROAD	91352	6	198B165     8	2629007001	C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.24183	-118.39677	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 6844 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64326	16041-20003-07883	7922 N HASKELL AVE	91406	6	189B141   117	2206001009	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			PC Approved	07/08/2016 12:00:00 AM	ADDRESS	34.21463	-118.47476	Change of location of 30 kVA transformer.  ((Revisions to approved set.  Change of service voltage class to reflect site conditions and additional transformer proposed to accommodate service ratings.  Change of THWN-2 to PV wire.  Change of roof layout.  Change of inverter model and rating.))  (((Install a roof mounted solar array on a Commercial building. Interconnect with a 600A MSP.System size: 20kW. (64) 315W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64327	16041-10000-13004	16300 W VENTURA BLVD	91436	5	168B137   424	2284001048	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.15674	-118.48819	NEW FIRE ALARM SYSTEM 140 DEVICES WITH FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64328	15041-10000-11347	1655 E 14TH ST	90021	14	121-5A213 263	5130024026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.02623	-118.24136	Tenant improvement to existing warehouse/office space two stories,  No change of use.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 437.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64329	18041-10002-00801	854 N VERMONT AVE	90029	13	144B197  1388	5539010021	[Q]C2-1	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	34.08686	-118.29152	SUPPLEMENTAL TO APPROVED SET SINGLE LINE DIAGRAM UPDATE ONLY. NO PLAN CHECK FOR POWER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64330	15041-10003-27973	6201 W HOLLYWOOD BLVD SUITE 116	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			Corrections Issued	02/25/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	02-25-16 Change to approved set of plans. Changes include revised Title 24 Plan check. {{{{{{{PC FOR ENERGY ONLY ON EXISTING COMMERCIAL (NAIL SALON) 1-STORY BUILDING. SCOPE INCLUDES NEW PANELS AND LIGHTING. TOTAL AREA IS 1558 SQ. FT.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64331	15041-10000-25163	1100 E 14TH ST	90021	14	123A211   434	5132022001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/05/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Expired	09/14/2017 12:00:00 AM	ADDRESS	34.02925	-118.24904	SERVICE UPGRADE OF 800 AMPS AND T-24, ENERGY CHECK FOR  A COMMERCIAL BLDG. (1) PANEL 800 A. (1) LIGHT FIXTURE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64332	15041-20000-42077	6713 N NESTLE AVE	91335	3	180B125   169	2125018025	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.19251	-118.53091	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.08KWdc/3.0KWac.(8)MODULES-CANADIAN SOLAR CS6P-201 265P(1)INVERTER-SUNNYBOY SMA SB3000TL-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64333	13041-20000-23815	17828 W TULSA ST	91344	12	210B129   831	2712020004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.26835	-118.52265	PV1 4 STRINGS FOR 1 INVERTER. 25 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 8.175KW. 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64334	18041-10000-11047	600 N PERUGIA WAY	90077	5	141B149   218	4362003012	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM			PC Approved	05/01/2018 12:00:00 AM	ADDRESS	34.08032	-118.44867	NEW 10,000 SQR FT 2-STORY S.F..D WITH ATTACHED 3-CAR GARAGE AND 600 AMP SERVICE.PLAN CHECK ONLY. PERMIT WAS PAID UNDER BLDG PERMIT # 16010-30000-00325.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64335	18041-20000-46088	3831 S HUGHES AVE 701	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.02242	-118.39823	ti to an existing medical office.  adding new lighting new controls to new panel.  plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64336	19041-20000-34682	4217 1/2 W BURNS AVE	90029	13	144A201   296	5539007020	RD1.5-1XL	Central	Hollywood	East Hollywood	YES	1914.10	Electrical	Electrical	Apartment			09/03/2019 12:00:00 AM	09/03/2019 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.0878	-118.28509	PLAN CHECK FOR INSTALLATION OF 2 NEW SUB PANELS WITH EXISTING LOADS IN EXISTING APARTMENT UNITS 4217 AND 4217 1/2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64337	17041-10000-13051	635 S TOWNE AVE	90021	14	126A213   159	5147027044	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.04048	-118.24454	PC for energy only, Indoor Title-24.  Removing HID fixtures and replacing with New LED. area: 4,950.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64338	18041-10000-19611	3201 S HOOVER ST STE 1824	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.0255	-118.28448	Energy plan check for a change of use T.I. located in the ground level. Scope includes new lighting and equipment. Total area is 1205-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64339	14041-20001-33555	6111 W MULHOLLAND HWY	90068	4	159B189    42	5581015014	RE9-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.13043	-118.32138	2/25/2015 - Supplemental application for changes to approved set.  Addition of 1 new module (new total = 36) and changing all modules from Sunedison F275KYC to Sunedison F270KZC.*****Previous Work Description*****PV1MICROINVERTER STANDARD PLAN SYSTEM SIZE 8.4KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64340	15041-10000-31896	2011 S SAWTELLE BLVD	90025	11	126B153   742	4261033011	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM			PC Info Complete	09/25/2015 12:00:00 AM	ADDRESS	34.04048	-118.44344	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTIN NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 279.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64341	17041-10000-23754	7340 N FULTON AVE	91605	2	186B157   435	2327001025	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.20405	-118.4224	T-24, REPLACE INDOOR AND OUTDOOR FIXTURES WITH LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64342	17041-10000-13055	11788 W PICO BLVD	90064	11	123B149   865	4260030005	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.03057	-118.44732	PC for energy only, Outdoor Title-24.  Removing HID fixtures and replacing with New LED. area: 3,425	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64343	13041-20000-24257	11627 N GERALD AVE PV-1	91344	12	213B137   305	2610024015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.28181	-118.49469	PV-1. Plan check for roof mounted with one 4.2kW inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64344	16041-20000-16947	810 W DOWNEY WAY 101 &-210	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.01956	-118.28642	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 646 sq. ft.Note: Building application has been created under 16016-10000-10722	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64345	17041-20000-29351	9738 N HASKELL AVE	91343	12	201B141   326	2671003009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.24751	-118.47604	Plan check for a PV1 roof-mounted PV system. System size is 2.8 kWac and consists of (12) modules and (12) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64346	11041-10000-25848	16200 W PARTHENIA ST	91343	12	195B137   956	2689024022	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	ADDRESS	34.22816	-118.48587	P/check for T-24 lighting compliance including emergency egress lighting and exit signs.(CHANGE PROTION OF EXISTING BUILDING USE FROM RETAIL TO RESTAURANT; 1,455 S.F.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64347	16041-10000-20281	5825 S MEADOWLARK PL	90094	11	102B161  1272	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	33.97526	-118.41593	NEW F.A. FOR APT. INCLUDING 46 DEVICES 1 PANEL  2 COMM. PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64348	17041-10000-30859	3636 S SEPULVEDA BLVD 1-363	90034	5	117B157   385	4252006025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	Apartment			08/29/2017 12:00:00 AM			PC Info Complete	08/29/2017 12:00:00 AM	ADDRESS	34.01569	-118.41916	PC FOR ENERGY ONLY T24. REPLACEMENT LIGHITNG IN CORRIDORS AND STAIRWELLS. PROVIDED UPDATED LIGHTING AND PHOTOMETRICS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64349	11041-10000-23742	514 S SHATTO PL	90020	13	135B197   850	5077004025	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.06457	-118.28971	T.I. to an existing office building.  No changes to shaded areas on plans per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64350	14041-10000-26848	1501 W L ST	90744	15	033B201    66	7412010903	OS-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	33.78614	-118.28349	600 A service upgrade for a park area.  Replace two existing services with a new service and a connected distribution panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64351	12041-10000-17330	1547 N CASSIL PL	90028	13	148-5A185 296	5547019014	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Apartment			07/25/2012 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.09938	-118.33393	Plan check for energy and emergency lighting. 2642sqft (712 outdoor sqft). 4-unit apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64352	14041-20002-10131	6028 S EILEEN AVE	90043	8	105B181   741	4004023007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.98453	-118.34272	MODIFICATION OF APPROVED SET - ADDITION OF A SINGLE AC DISCONNECT ONLYFEE IS $0.00 DUE TO STATE SENATE BILL 1222[[[pv1 single family dwelling. total system size 3.8kw ac using transformerless inverter nonstandard plan. using power optimizers.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64353	17041-20000-04893	849 S BROADWAY	90014	14	127-5A209 313	5144017***	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.04271	-118.256	Facade lighting for (E) commercial building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64354	18041-10000-31002	6201 W LA MIRADA AVE 1-8	90038	13	144B189   170	5534001022	R3-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Apartment			08/15/2018 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	11/17/2021 12:00:00 AM	ADDRESS	34.09359	-118.32468	NEW 3-STORY, (8) UNIT APARTMENT BUILDING WITH GROUND FLOOR PARKING & 600 AMP SERVICE.BUILDING PERMIT: 16010-70000-04214	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64355	18041-20000-04964	2450 E HOUSTON ST	90033	14	130-5A225 326	5177021003	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	07/10/2023 12:00:00 AM	ADDRESS	34.05032	-118.20346	Plan check for power and energy. Project site is a 3-story, 10-unit apartment building. Work includes a 600 amp service and a total lighting area of 1,600 sq. ft.Note: Building application has been generated under 17010-10000-04210	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64356	11041-10001-07839	8039 S VERMONT AVE	90044	8	099B197   966	6033021018	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM	05/02/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	ADDRESS	33.96567	-118.292	addition of 12 ea  in-duct smoke detectors((((((((((NEW FIRE ALARM. 111 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64357	17041-20000-37841	1333 N SIERRA BONITA AVE	90046	4	147B177  1376	5550027012	R3-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Apartment			10/20/2017 12:00:00 AM	06/20/2018 12:00:00 AM		Issued	06/20/2018 12:00:00 AM	ADDRESS	34.09531	-118.35409	Plan check for power and energy. New 4-story, 6-unit apartment building above one level subtarranean parking. 600A service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64358	14041-10000-25494	1333 S MEYLER ST	90731	15	012B197   173	7458019022	R2-1XL	Harbor	San Pedro	Central San Pedro		2969.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	33.73185	-118.29694	Installation of solar roof mounted microinverter array.  Total system size = 2.3 kWac.  DC combiner box is installed with AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64359	16041-20000-02253	10801 W FOOTHILL BLVD	91342	7	210B173    47	2529021007	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Refund in Progress	01/05/2017 12:00:00 AM	ADDRESS	34.27465	-118.36636	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. Standard plan in use.(30) Kyocera KU265 Modules(1) ABB PVI-6000  Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64360	19041-20000-53784	19515 W NORDHOFF ST SUITE 5-BLDG D	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	01/13/2021 12:00:00 AM		Permit Finaled	06/01/2021 12:00:00 AM	ADDRESS	34.23567	-118.55825	PLAN CHECK FOR POWER AND ENERGY ADD NEW PANELS AND EQUIPMENTS ON EXISTING 1600 A SERVICE. FIRST TIME TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64361	14041-10000-35609	8723 W ALDEN DR 2nd&3rd FL	90048	5	138B169   245	4334006022	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.0754	-118.38272	Plan check for new emergency and normal power for file server UPS units with 4 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64362	13041-10002-31237	1038-1048 S MARIPOSA AVE	90006	1	129B197   387	5078016016	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.05151	-118.2988	DELTA 3 REVISIONS IN THE FIELD: INVERTER WAS REMOVED AND UNIT EQUPMENT USED FOR EGRESS ILLUMINATIONCHANGES ARE CLOUDED AND IDENTIFIED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64363	15041-20000-27493	10113 N WISH AVE	91325	12	204B133   411	2694004014	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.25454	-118.50796	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (34) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64364	15041-10000-16134	17578 W TUSCAN DR	91344	12	222B129   256	2601044014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.3025	-118.51649	PV1, ROOF MOUNTED SOLAR SYSTEM. 18 MODULES AND 1 INVERTER. TOTAL SIZE:  5 KW. SUBMITTED PER APPLICANTS REQUEST. (18) SUNPOWER SPR327NE-WHT-D(1) ABB PV1-5000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64365	18041-10000-03019	444 S SAN VICENTE BLVD #6017D	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.07021	-118.37547	PC for power for new water heaters and hvac in sedars sinai corridor and imaging room. Plan check per applicants request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64366	19041-10000-36260	21812 W SHERMAN WAY	91303	3	183B105   158	2111024005	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.20085	-118.6033	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64367	19041-10000-15031	7701 N QUAKERTOWN AVE	91306	3	189B113  1227	2106005023	C1-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.21071	-118.57002	[e-plan] PV1. PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLAREDGE-SE7600H-US) WITH 28 MODULES(PANASONIC 325W) USING SE P400 OPTIMIZERS. SYSTEM SIZE IS 9.1KWdc AND 7.6KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64368	12041-10001-00848	2410 W JEFFERSON BLVD	90018	10	120B189   724	5044031005	C2-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2190.20	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.02544	-118.32163	REVISIONS TO PERMITTED SET OF PLANS; THE UTILITY HAS ISSUED ITS SERVICE REPORT WHICH SHOWS THE AVAILABLE SHORT CIRCUIT CURRENT AT THE POINT OF SERVICE TO BE 100KA -NOT 65KA. SINGLE LINE IS REVISED AND CHANGES BUBBLED TO ACCOMODATE FOR THIS SHORT CIRCUIT CURRENT CHANGE((((((((New 40 unit apartment building with unkown service size.   <<<<<Customer has a pre-printed check, fees are based on customers estimate.  Additional fees to be collected for Energy, etc to be around $23,000>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64369	17041-10000-02049	12475 W BRANFORD ST	91331	7	201B165   105	2624018802	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.24709	-118.4051	PC FOR POWER ONLY. INSTALLING NEW CNG PRESSURE TANKS AND SERVICE UPGRADE TO 1200 A, 277/480V, 3PHASE, 4-WIRE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64370	18041-20000-18449	14832 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.29496	-118.45421	PV1.  Install 3.78 kW roof mounted grid tied PV system.  (12) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64371	18041-20000-47163	7868 N CANTALOUPE AVE	91402	6	189B153   656	2214012021	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Expired	05/18/2024 12:00:00 AM	ADDRESS	34.21375	-118.43351	Plan check for the addition of (2) battery back-up units to an existing (E) PV1 roof-mounted PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64372	17041-20001-35667	3055 W 5TH ST	90020	13	135A201    53	5077001016	R4-2	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.06535	-118.28598	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.44 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64373	17041-10000-09504	1920 S BRONSON AVE	90018	10	126B185  1086	5060007004	C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.01	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.03912	-118.33001	PC for energy only, outdoor only. Removing HID fixtures and replacing them with new LED ones. Area: 51,000.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64374	13041-10001-10581	380 W WORLD WAY T36	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	[[[[[[ DELTA 2 CHANGES ONLY, CHANGING AND AVAILABLE 250W EMERGENCY INVERTER TO 350W EMERGENCY INVERTER, PERMIT IS EXISTING]]]]]]]]per customer's request, application taken in as full plan check (T24 has already been done). power fees to be added under submittal 2. for concession space #T36-R (Michael Kors)FIRST TIME TENENT IN TBIT. SPACE 36. TOTAL AREA 800 SQ FT. PLAN CHECK FOR T24 ENERGY ONLY PER SUPERVISOR REQUEST. RETAIL STORE. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64375	19041-10000-08363	1012 S WESTMORELAND AVE	90006	1	129B197   271	5076008001	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			03/08/2019 12:00:00 AM			Reviewed by Supervisor	04/09/2019 12:00:00 AM	ADDRESS	34.05197	-118.28892	Full plan check for complete new service equiptment  upgrade on a 2-story, 60 unit apartment building with (3) address. Scope includes new service, new distribution panels and new subpanel. No new load added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64376	12041-10000-30434	2011 N SOTO ST	90031	1	135A227     2	5211021004	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20, 2033.00	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	PIN	34.06587468	-118.19737837	TWO STORY TENANT IMPROVEMENT WORK. PLAN CHECK FOR POWER TITLE 24 AND EMERGENCY LIGHTS (71590 SQ FT) AT USC. NEW CONNECTED LOAD EXCEEDS 400A, TITLE 24 AREA EXCEEDS 30000 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64377	14041-20008-17303	5808 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	01/13/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 18. Changes include the addition of a transformer and subpanel for EV chargers.12/08/2016 Changes to approved set.  Delta-17 changes: miscellaneous revisons to mechanical equipment ratings and connection points - feed cooling tower spray pumps from panel 14LA.10/18/2016 Changes to an approved set of plans. Changes have been made to the OCPD of the EM generator. All changes have been clouded.9.1.2016 - Plan check for changes to approved set. Update panel schedules and floor plans to reflect as built conditions. Removing first floor lobby lighting from scope of project. Changes clouded delta 15.8/18/2016Plan check for changes to approved set.  Add series rating for LA panels. Add insulated ground conductor for flex conduit.  Revised various mechanical equipment. Changes clouded delta-14. 6/11/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 2 and Delta 3. Changes include downsizing the EM generator to 800 kW from 1000 kW, the EM distribution board has been separated to have sections, 10 new lighting control panels, the addition of 2 new civil sump pumps, addition of fire smoke damper circuits, relocation of additional circuits and upsizing of water heater circuit breakers. *****Previous Work Description*****A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64378	14041-10000-08218	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT RETAIL STORE.  Change of use , 30 days variance submitted in liu of load sduy in accordence to article 220-87.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64379	15041-10000-16523	600 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	Installation of 10.2 sq. ft. LED sign.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64380	15041-20000-34143	23220 W ERWIN ST	91367	3	177B093   366	2035023031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.18262	-118.63236	PV1, roof mounted solar system 6.89 kW. (26) modules: #KU2656ZPA, (1) PVI-6000-OUTD-US. Simplified standard plan provided	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64381	13041-10000-23430	1100 S FLOWER ST 3RD FLOOR	90015	14	127-5A207 224	5138014015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			PC Approved	09/11/2013 12:00:00 AM	ADDRESS	34.04273	-118.26409	TITLE-24 ONLY FOR INTERIOR RENOVATION OF EXISTING OFFICE SPACE OF 6995 SF .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64382	18041-10001-08889	1648 N KINGSLEY DR	90027	13	148-5A195 129	5544015010	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	ADDRESS	34.10129	-118.30303	expedite per applicant request(((((Plan check for PV roof mounted system. System size: 18kWac with 75 moduels and 2 inverters(5.2kW) and 1  inverter(7.6kW) conncted to MSP)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64383	19041-10000-51563	718 S HILL ST STE 100	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	06/18/2021 12:00:00 AM		Permit Finaled	11/20/2021 12:00:00 AM	ADDRESS	34.04527	-118.25477	First time tenant. New restaurant. Plan check for power & Energy. Affected area: 6,632 SFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64384	14041-20000-21041	532 S IRVING BLVD	90020	4	135B189   768	5504010003	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.0642	-118.31833	New roof mounted PV system with Enphase model M250-60-2LL.  Total system 14KW.FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64385	17041-20001-45995	1753 S VIRGINIA ROAD	90019	10	126B185   644	5071007062	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM			PC Approved	01/02/2018 12:00:00 AM	ADDRESS	34.04192	-118.33418	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 18.72KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64386	13041-20000-14236	5900 W WILSHIRE BLVD 14th floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM			PC Approved	06/04/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	T24 FOR EXISTING HIGH RISE OFFICE SPACE. SCOPE OF WORK ON THE 14TH FLOOR. 481 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64387	16041-20001-35265	10457 N HANNA AVE	91311	12	207B101   250	2723019145	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/25/2016 12:00:00 AM	ADDRESS	34.26066	-118.60748	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (52) modules, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64388	17041-10000-05065	1430 W 240TH ST	90710	15	042B193   772	7439012003	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	33.80718	-118.30302	T-24, PC FOR ENERGY ONLY. REPLACE HID FIXTURES WITH NEW LEDs FOR INDOOR/OUTDOOR USE. TOTAL AFFECTED AREA IS 35600 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64389	19041-20000-46474	24022 W SCHOENBORN ST	91304	12	192B089   149	2017037017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Issued	11/12/2019 12:00:00 AM	ADDRESS	34.22111	-118.64972	PLAN CHECK FOR NEW ESS. ESS SIZE IS 13.5 KWH. SCOPE OF WORK CONSISTS OF (1) 5.8 KVA BATTERY, AND (2) 200A PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64390	12041-20000-01209	19064 W KILLOCH WAY	91326	12	219B121   404	2820012021	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2012 12:00:00 AM			Reviewed by Supervisor	03/07/2012 12:00:00 AM	ADDRESS	34.29297	-118.54908	pv system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64391	19041-10000-04537	3825 S CRENSHAW BLVD	90008	10	117B185   569	5045018038	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.01718	-118.33567	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64392	14041-10000-03351	11351 W CALVERT ST	91606	2	177B173   734	2336029002	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.18135	-118.37868	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 75A MAIN, 1PH, 240V. SYSTEM IS 1.96 kW DC; MICROINVERTER SYSTEM PERFORMED ON NON-STANDARD PLAN. SYSTEM IS CONSISTS OF (8) TRINA SOLAR TSM-245, (8) M215 ENPHASE MICROINVERTER, (1) 50A SUBPANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64393	19041-10000-33098	6561 N KELVIN AVE	91306	3	180B109   427	2148023006	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.19018	-118.5865	$0 FEE DUE TO AB1414. [E-PLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 11.4KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 37 MODULES USING P400 OPTIMIZERSMAIN BREAKER DERATING UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64394	11041-20000-00720	12035 E WATERFRONT DR Bldg 2	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			01/12/2011 12:00:00 AM	02/04/2011 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	PIN	33.98229149	-118.40627052	Plan check for new installation of roof mounted 34.29 KW Photovoltaic System on Building 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64395	13041-20003-32028	3969 N GOODLAND AVE	91604	2	162B161   292	2384018028	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.14235	-118.4107	Modifications to approved set.  Changes to roof layout (approved by fire department).  $0 submittal fee due to Senate BIll SB-1222. (((PV1.  Install 11 kW DC roof-mounted PV system, interconnect with main service panel.  44 modules: Renesola JC250M-24/BB.  2 transformerless inverters: SolarEdge SE5000A-US)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64396	10041-10000-21764	1800 S AVENUE OF THE STARS 4th floor-8th floor	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM			PC Info Complete	11/01/2010 12:00:00 AM	ADDRESS	34.06095	-118.41786	Ti in an existing office. Plan check for T24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64397	13041-10000-10475	20000 S WESTERN AVE BLDG 1	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.85008	-118.30908	TI OF EXISTING WAREHOUSE SPACE. CREATING PARTITION. NEW DISTRIBUTION BOARD AND LIGHTING. PLAN CHECK FOR POWER AND ENERGY. TOTAL AREA 154000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64398	16041-10001-13146	901 S GRAMERCY DR 1-21	90019	4	132B193   877	5092023013	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.05556	-118.31236	PC FOR CHANGES TO APPROVED SET UNDER DELTA 2. SCOPE INCLUDES REVISIONS TO SERVICE ENTRANCE CONDUCTORS, OCPD  AND LOCATION OF PANELS. THIS IS PLAN CHECK ONLY. PERMIT FEES PAID UNDER MASTER. Full Plan check to a new 4 story multifamily resdidential building (21 units). 7 Typical units.  New 1200 A service 120/240V 3 phase 4W. Total sqft = 17,345	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64399	17041-20001-24067	6820 W HOLLYWOOD BLVD	90028	13	148-5A185 158	5548006017	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.10138	-118.33947	11/3/2017change of address from 6822 W. hollywood Blvd.original plans lost. plan check for indoor energy only.Permit fees for electrical paid under master 17041-20000-24067	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64400	19041-20000-07517	20843 W HAYNES ST	91306	3	180B109   379	2148024012	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.19038	-118.58782	PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM 5.85 KW DC/5.22 KW AC. SCOPE OF WORK INCLUDES (18) CANDAIAN SOLAR CS1K-325MS PV MODULES AND ENPHASE IQ7PLUS-60-X-US 240VAC MICROINVERTERS, AND A 60A PV LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64401	11041-10000-20650	1033-1041 E ELKGROVE AVE BLDG 39	90291	11	111B145   567	4243003042	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.00111	-118.45911	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64402	18041-10002-11803	18133 W VENTURA BLVD 2ND FLR	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.16603	-118.52861	Changes to an approved set of plans, Note changes on clouded area AS10. Scope of work inlcudes the revision and addition of lighting to T-24, revision of single line diagram and addition of panel. ___________________________________________________________________________FULL PC FOR A PARTIAL FLOOR TI FOR MEDICAL OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES FOR OFFICES AND BLOOD DRAW ROOM. TOTAL SQ. FT. 1715.Blgd Permit #13020-10K-00933	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64403	12041-20000-24929	4136 N COLFAX AVE	91604	2	162B169   106	2368010013	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2012 12:00:00 AM	11/20/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.14369	-118.38738	Photo voltaic system using Enphase M215 inverters on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64404	08041-20002-27421	3333 S MANNING AVE	90064	5	123B161   812	4316032011	R3-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			11/16/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	34.03112	-118.40638	Plan check revision to approved plans Delta 1 to Include new optional stand by generator, ckts, panels, and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64405	15041-20000-00784	12863 W FILMORE ST	91331	7	213B161   835	2533028037	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.278	-118.41331	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64406	19041-10000-52460	10309 W SANTA MONICA BLVD #300	90025	5	132B157   365	4327017017	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Issued	12/19/2019 12:00:00 AM	ADDRESS	34.05936	-118.42182	REPLACE FLUORESCENT TROFFER WITH NEW LED RETROFIT KIT ON 3RD FLOOR. INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64407	10041-20000-13732	22601 W LASSEN ST	91311	12	204B097    41	2724005902	A1-1XL	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11, 1132.13	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	34.25009	-118.61925	TI IN CEMETRY. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64408	10041-30000-00105	1 W WORLD WAY	90045	11	090B165    93	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Public Safety Only			01/05/2010 12:00:00 AM	01/05/2010 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	PIN	33.94415688	-118.4024579	LAX parking structure 2A - replacement of FA control panel w/ smoke detectors.  Compatibility list provided for plan check.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64409	18041-10000-09644	4151 W DUNDEE DR	90027	4	154-5A201  43	5592017032	RS-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	05/04/2020 12:00:00 AM	ADDRESS	34.11823	-118.28409	PC  FOR POWER UPGRADE IN SFD. PROPOSED SERVICE SIZE 600 1PH 120/240V.ALL SUBPANEL ARE NOT INSCOPE OF THIS SUBMITTELB#17016-30000-15995  Interior remodel  of  acc. living quaters/sfd to include kitchen/bathrooms/remove interior walls/add paralam beams/new foundations pads per Engineer's plans(See comments).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64410	19041-20000-02207	4450 N CALLADA PL	91356	3	165B121    29	2177012027	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.15252	-118.54259	PV1.  Install 11.84 kW DC / 10.79 kW CEC-AC roof mounted grid tied PV system.  (37) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64411	19041-20000-53234	110 E 9TH ST 5TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.04107	-118.25479	Plan check for Title 24 Energy only in existing space. Installed new track lighting in addition of  existing lighting fixtures. Total area: 15,742 sq ft, B#19016-10000-14525	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64412	16041-20001-16608	4323 N SHADYGLADE AVE	91604	2	165B165   538	2367002017	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM			PC Approved	05/17/2016 12:00:00 AM	ADDRESS	34.14933	-118.40203	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 6.3kW with 2 inverters(3.0 and 3.3kW) and 31 modules.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64413	16041-10000-45228	10250 W SANTA MONICA BLVD # 1995	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""Papyrus"" Ste. 1995.  Install new wiring, and  panels, total area 904 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64414	15041-10002-43403	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM			Corrections Issued	10/27/2017 12:00:00 AM	ADDRESS	34.03365	-118.24048	Changes to an approved set of plans, Changes include relocating electrical equipment. Changes are under delta 1 only. ****Full plan check for retail spaces at first level of a parking structure, owner build out. Newly connected load is less than 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64415	19041-20000-13218	22865 S LOCKNESS AVE	90501	15	045B193   471	7347017061	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	33.81751	-118.30671	T24 PLAN CHECK FOR LIGHTING AND OUTLETS ONLY FOR EXISTING COMMERCIAL WAREHOUSE/SHOW ROOM. TOTAL SQUARE FOOTAGE = 2495SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64416	19041-10000-13714	3051 S MCCONNELL DR	90064	13	156B209   218	5458004016	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	06/15/2019 12:00:00 AM	ADDRESS	34.03591	-118.40165	*Zero dollar permit fee per AB-1414/SB-1222*(ePlan)  RESIDENTIAL SOLAR ROOFMOUNT 19.25KW DC, 17.584 AC-CEC (55) SUNPOWER  AC MODULES. (1) 200A SOLAR LOAD CENTERNOTE; MAIN BREAKER DERATE TO 175A  AND NEW 225MSP SHALL BE UNDER SEPARATE EXPRESS PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64417	12041-10000-18071	630 W HARRY BRIDGES BLVD Ped Bridge	90744	15	027B205   523	7440015***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	33.77068	-118.26868	NEW PEDESTRIAN BRIDGE FOR PORT OF LA.  EPC IS FOR POWER & ENERGY. (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64418	19041-10000-33439	1800 W BEVERLY BLVD	90057	13	135A205   320	5154001020	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	09/10/2021 12:00:00 AM		Issued	09/10/2021 12:00:00 AM	ADDRESS	34.06495	-118.26724	FULL PLAN CHECK FOR POWER AND ENERGY FOR A  NEW 6 STORY, TYPE IA/VA, MIXED USE BUILDING OVER TWO STORY, TYPE IA, COMMERCIAL & PARKING GARAGE. THE GROUND FLOOR COMMERCIAL IS FOR RETAIL / RESTAURANT & PARKING, AND THE 4 STORY, TYPE VA, ABOVE, 243 APARTMENTS. SYSTEM SIZE IS 5000A THREE PHASE FOUR WIRE. SCOPE OF WORK INCUDES SEVEN DISTRIBUTION BOARDS OVER 1200A, FEEDING VARIOUS SUBPANELS FOR THE DWELLING UNITS AND HOUSE LOADS. TOTAL AFFECTED AREA IS 180,025 SQFT (INDOOR AND OUTDOOR)NOTE THERE ARE 5 TYPICAL UNITS B#18010-10000-05986	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64419	15041-10001-41225	810 E PICO BLVD # 316	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	ADDRESS	34.03119	-118.25079	01/26/16Changes to an approved set of plans. All changes made under delta 1. Scope includes adding new lights to office space and display area. (((((ALTERATIONS IN EXISTING OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64420	12041-10001-30549	8511 W BEVERLY PL	90048	5	138B173   350	4337012040	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.07669	-118.37705	"VERIFICATION IN PROGRESS. NEW T24 ENERGY SUBMITTED AND CHANGES FROM ORIGINAL SUBMITTAL. ASSIGN TO PETER U.COMPLY WITH DEPARTMENT ORDER effective date 5/14/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""NEW  4 STORY  PRIVATE SCHOOL BUILDING OVER ONE SUBTERRANEAN LEVEL OF PARKING. PLAN CHECK FOR POWER AND ENERGY FOR AN ADDITION TO AN ACADEMY (CHARTER SCHOOL). PROJECT IS LOCATED IN A METHANE ZONE. PROJECT SCOPE IS OVER 55000 SQUARE FEET AND INCLUDES A NEW SERVICE PER APPLICANT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64421	13041-10000-06921	7920 W SUNSET BLVD Suite 200	90046	4	147B177  1012	5554001012	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.09787	-118.36238	T24 FOR EXISTING HIGH RISE OFFICE BUILDING. SQRFT 10484. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64422	13041-10000-32222	5857 S CENTRAL AVE # 140	90001	9	108B209  1588	5103024034	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	CHANGE OF USE & INTERIOR TENANT IMPROVEMENT OF AN EXISTING EMPTY SHELL (RETAIL) INTO A WABA GRILL FAST FOOD RESTAURANT -	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64423	16041-20000-10585	17946 W VENTURA BLVD	91316	5	171B129   259	2182001007	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.16401	-118.52371	Plan check for power and energy. Change of use for 80' x 30' retail building to new medical office. New lighting and wiring. Subject to Article 517.  Not OSHPD 3 per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64424	19041-10000-25213	6633 N VAN NUYS BLVD	91405	6	180B149   300	2236010005	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM			PC Info Complete	04/21/2021 12:00:00 AM	ADDRESS	34.19157	-118.44902	FULL PLAN CHECK FOR POWER AND ENERGY. CHANGE OF USE FROM (E) RETAIL TO GYM. INTERIOR IMPROVEMENTS. NEW 1000 AMP SERVICE, 120/240, 3PH, 3W.  TOTAL SQ. FT. 21067.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64425	19041-20000-36138	7260 W SUMMITROSE ST	91042	7	204B197   138	2565010048	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.2594	-118.29069	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM AND BATTERY STORAGE SYSTEM ON EXISTING SFD. PV SYSTEM SIZE IS 4.725 KW DC/5 KW AC. BATTERY SYSTEM SIZE IS 13.5 KWH. SCOPE OF WORK CONSISTS OF (15) PV MODULES, A 5 KW INVERTER, A 5KW BATTERY, AND A 125A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64426	18041-20001-06919	20428 W CALIFA ST	91367	3	174B109   109	2151015028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM			PC Approved	03/03/2018 12:00:00 AM	ADDRESS	34.1763	-118.57842	expeditepv1install roof mounted pv system sized 15.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64427	19041-10000-02735	6020 N ELMER AVE	91606	2	177B173  1050	2337007008	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.18014	-118.37683	***Application Witdrawn*** Per applicant's request. Duplicate permit. Permit# 19041-1000-29861((((PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 5KW SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SE5000H-US) WITH 21 MODULES USING P320 OPTIMIZERS ON A SINGLE FAMILY HOME.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64428	17041-20000-12335	929 W JEFFERSON BLVD BLDG 6-UNIT 1500	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. GREENLEAF AT USC. BUILDING PERMIT # 14010-10000- 00446	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64429	18041-10000-31388	8500 W BEVERLY BLVD #605	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Info Complete	08/17/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	Energy plan check for retail T.I located in Beverly Center. Scope includes new lighting and equipment with a total area of 801-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64430	11041-20000-11773	19720 W VENTURA BLVD	91364	3	174B117   366	2164011024	C1-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			PC Approved	07/01/2011 12:00:00 AM	ADDRESS	34.17232	-118.56318	T.I.  Existing parking lot.  Modification to prking lot lights.  Title-24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64431	19041-10000-52564	694 S OXFORD AVE	90005	10	132B193   240	5093006900	CR-2, P-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Info Complete	04/07/2022 12:00:00 AM	ADDRESS	34.06001	-118.30763	NEW Parking structure. Install new panels, transformer, circuits, lights & EV chargers. Affected area for lighting energy compliance: 43700 sqft.***Building Permit: 19010-10000-05842: (N) 50 car underground parking structure with (N) rooftop park at grade	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64432	17041-30000-19813	6038 N JUMILLA AVE	91367	3	177B117   572	2153021013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Issued	06/13/2017 12:00:00 AM	ADDRESS	34.18041	-118.56352	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter and (23) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64433	15041-20000-13493	1940 S LONG BEACH AVE EAST	90058	9	118-5A213 352	5167013039	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.01935	-118.24271	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012Plan check for solar mounted roof top for commercial with 82.6 kW with 295 modules and 3 inverters(27.6kW) connected to load center(200A panel)Note: Fire approve is require prior electrical approval	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64434	19041-10000-39316	9000-9038 N BALBOA BLVD	91325	12	195B133   100	2688026010	RA-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	07/16/2020 12:00:00 AM		Permit Finaled	03/04/2022 12:00:00 AM	ADDRESS	34.23401	-118.50234	ENERGY PLAN CHECK FOR EXISTING CANOPY OVERHANG AT IN LINE BUILDINGS, NEW CANOPY AND MINOR FACADE REMODEL FOR IN LINE BUILDINGS, NEW CURB RAMP AND PARAPET, NO INTERIOR WORK. AREA OF SCOPE 30833SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64435	14041-10000-15565	1038 W PRINCETON DR	90292	11	105B149   516	4229003048	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	33.9859	-118.44654	Title 24 PLAN CHECK FOR POWER FOR EXISTING  2-stories OFFICE BUILDING.  SERVICE UPGRADE AND NEW PANELS AND LOADS. were approved on 14041-10000-13563	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64436	17041-10000-34292	1630 W 186TH ST	90248	15	060B193   248	6108002022	P-1VL, [Q]MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	33.86187	-118.30705	PC for power and energy for hyrdrogen service garage (Hazardous location). Intalling new receptacle, vehicle service lifts, two panels and 45kVA transformer. Total area of 3070sqft. B# 17016-10000-27940.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64437	19041-20000-32574	2717 N NICHOLS CANYON ROAD	90046	4	156B177   759	5570003017	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.12029	-118.35701	PV1 PLAN CHECK FOR ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.96 KW DC/11.34KW AC. SCOPE OF WORK CONSISTS OF (36) PV MODULES WITH MICROINVERTERS, AND A NEW SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64438	17041-20000-45768	13526 W CREWE ST	91405	2	183B157   649	2328011042	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	PIN	34.19641256	-118.42777302	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (45) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64439	16041-20000-30853	21650 W OXNARD ST #200	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	01/25/2017 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for Title 24 only. Project site is an existing tenant space on the 2nd floor within a commercial building. Project scope is a tenant improvement/change of use from office to adult education. Total lighting area = 11,674 sq. ft.Note: Building application has been generated under 16016-10000-19273	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64440	11041-20003-26376	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	06/07/2013 12:00:00 AM	ADDRESS	33.98645	-118.44148	Delta 6 modification to plan to show existing emergency panels on the single line diagram, and to provide interior and exterior emergency lighting using unit equipment and lighting connected to emergency generator.  No new lighting added to change T-24 lighting requirements.  Rewired lighting connected to emergency panels to be controlled as normal lighting with all required controls, interior and exterior.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64441	10041-10000-15136	1521 W FRANCISCO ST Bldg A	90501	15	057B193    25	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	33.8496	-118.30518	New building.  New service, panels, and branch circuits.  Plan check for energy and power.NOTE: refer to 10041-10K-15139 for  Bldg B	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64442	16041-10000-10548	3220 W 18TH ST	90019	10	126B189   767	5072030011	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.04073	-118.31978	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND DERATE OF MAIN BREAKER. (10) KYOCERA-#KD255GX MODULES AND (1) ABB# PV1-3.0 INVERTER AT 3KW. TOTAL SYSTEM SIZE IS 3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64443	10041-20000-01548	11150 W SANTA MONICA BLVD # 100	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM	02/12/2010 12:00:00 AM		Permit Finaled	05/13/2010 12:00:00 AM	ADDRESS	34.04704	-118.44563	Tenant improvement - remodel for new restrooms. Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64444	18041-10000-01501	7520 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20692	-118.4942	REMOVE INDOOR - OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 67600 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64445	12041-10000-22850	1727 N BARDALE AVE	90731	15	024B193   227	7442012002	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	33.76056	-118.3006	Roof-mounted 3.9 KW photovoltaic system of a SFD using Enphase M215 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64446	15041-20000-13515	6316 N TOPANGA CANYON BLVD STE B-1150	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and energy first time tenant Sur La Table at Village at Westfield Topanga.  Total area: 5317 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64447	17041-10000-40214	3531 N LOWELL AVE	90032	14	144A237   340	5219025019	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.08726	-118.16256	PLAN CHECK FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 3.8KWAC ( AC MODULES).SYSTEM INCLUDES 12 AC MODULES WITH NEW LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64448	16041-10001-10819	8500 W BEVERLY BLVD BASEMENT	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	08/26/2020 12:00:00 AM	ADDRESS	34.07587	-118.37754	SUPPLENTAL TO APPROVED SET-T-24,  NEW OFFICE ON PORTION OF PROPOSED STORAGE AREA  FOR MALL REBRANDING PROJECTS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. OF STORAGE BEING CONVERTED TO OFFICES = (640),   PLAN CHECK ONLY INCLUDES DELTA 1 REVISION ON PLANS. SUPPLEMENTAL UNDER APPLICATION 16041-10000-10819/E16LA01220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64449	17041-10000-05966	21225 W ROSCOE BLVD	91304	3	192B105   570	2779008011	R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.22	-118.59465	Plan check for Title 24 only in existing space replace Outdoor existing lighting fixtues with LED fixtues. Total area: 17,950 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64450	17041-10001-17275	1156 S VICTORIA AVE	90019	10	129B189   419	5082025021	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.05137	-118.32603	Expedite fees only.  Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  1 new Tesla AC Powerwall 5.8 kVA 13.0 kWH battery and 1 new Solicia 7.6 kWac TL inverter.       Online permit pulled under #17041-90000-10568	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64451	14041-10000-30612	11116 N TAMBERLY LANE	91042	7	210B197   570	2552048040	R1-1, RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.27137	-118.29283	Plan check for PV1 system. System size is 7.2 kW. System consists of (2) inverters and (18) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64452	15041-20001-04254	1450 N GENESEE AVE	90046	4	147B177  1047	5551023013	R1-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.09758	-118.35804	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD and detached garage. Interconnect with a 225A MSP (w/200A main).System size: 10.08kW. Ungrounded system.(42) EnPhase M250 microinverters with (42) 275W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64453	12041-20000-24720	9649 W LAWLEN WAY Wellness-Center	90210	5	144B161   412	4355019043	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	34.09484	-118.41636	Department error zero fees.  New wellness center.  Plan check fees paid on original application 12041-20000-07941.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64454	14041-10000-17491	1328 N LAKE SHORE AVE	90026	13	141A209   446	5419031010	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.07887	-118.25979	permit to be pulled at EPC counter only. Title 24 plan check only.  Total area = 5,927TI for a  retail space.  emergency lighting installed. New lighting and circuits. permit to be pulled at EPC counter only. Plan check for energy under 2008 Energy code. BLDG#14016.10.09966: CHANGE OF USE FROM  PHOTO STUDIO TO RETAIL. CHANGES ON PLAN INCLUDE: automatica daylighting controls and multilevel outdoor lighting controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64455	17041-10000-06771	127 S SAN VICENTE BLVD 5TH FLR	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	POWER PLAN CHECK ONLY TO MEDICAL OFFICE BUILDING TI RENOVATION ON 5TH FLOOR. RELOCATING SOME PANELS AND ADDITON OF ELECTRICAL EQUIPMENT. OSHPOD 3. SCOPE OF WORK IN  GENERAL OPERATING ROOM, PHARMACY, RECEIVING STORAGE ROOM, STORAGE ROOM, ENVIRONTAL SERVICES ROOM( JANITOR'S CLOSET) AND A PHYSICIAN READING ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64456	13041-10000-32776	1227 N HIGHLAND AVE	90038	4	144B185   362	5532006015	C2-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.09331	-118.33882	TITLE 24 PART 6 ENERGY LIGHTING WORK FOR AN EXISTING ART GALLERY SINGLE STORY (+MEZZANINE) BUILDING . SCOPE OF WORK IS < 400A. TOTAL SQ FT TO BE 22,787 SQ FT FOR COMBINED INDOOR AND OUTDOOR LIGHTS. LIGHTING IS DESIGNED W/ TAILOR METHOD FOR VARIOUS ART DISPLAYS.  (Complete Plan Check is required)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64457	19041-10000-01898	1003 S WESTMORELAND AVE	90006	1	129B197   309	5076009002	C2-1, R4-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	09/04/2019 12:00:00 AM	ADDRESS	34.05206	-118.28932	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64458	18041-20000-34461	12630 W MILLENNIUM	90094	11	102B161  1280	4211037036	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	33.9772	-118.41312	PV1.  Install 4.02 kW DC roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64459	19041-10000-22514	550 S HOPE ST # 440	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64460	19041-20000-04428	17831 W BAHAMA ST	91325	12	195B129   177	2768030004	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.2329	-118.5226	Plan check for PV roof mounted system and battery back up system, PV system size: 12.21KW DC, 11.24KW AC CEC with 37 PV modules and 37 microinverters and 1 Tesla Power Wall 13.2KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64461	18041-10001-22143	14626 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.22128	-118.45073	EXPEDITED FEE PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM FOR GROCERY STORE - SYSTEM SIZE = 86.6KVA SYSTEM CONSISTING OF 2 CENTRAL INVERTERS (SE10KUS AND SE66.6K) WITH 260 MODULES AND P370 POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64462	14041-10000-06733	3753 S GRAYBURN AVE	90018	10	117B185   390	5033009001	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/18/2016 12:00:00 AM	ADDRESS	34.01844	-118.33205	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64463	19041-10000-44488	7955 N LINDLEY AVE	91335	12	189B125   407	2102014056	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.21534	-118.52753	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64464	17041-10000-20729	10250 W SANTA MONICA BLVD # 1415	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check, First tenant- restaurant Sweetgreen Ste.# 1415	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64465	17041-20001-34928	4122 N ALLOTT AVE	91423	4	165B157  1054	2373010009	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2017 12:00:00 AM			PC Approved	10/03/2017 12:00:00 AM	ADDRESS	34.14518	-118.4281	10/03/2017 Changes to an approved set of plans. Inverter manufacturer has changed and PV system size is now 5 kWac. Module count has remained the same.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64466	19041-10000-31828	1715 W PACIFIC COAST HWY	90717	15	033B193    12	7410010019	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Issued	08/15/2019 12:00:00 AM	ADDRESS	33.78968	-118.30817	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64467	16041-10000-05371	1411 S SANTEE ST	90015	14	124-5A209 275	5133016004	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Expired	05/31/2018 12:00:00 AM	ADDRESS	34.03386	-118.25947	PC for energy only to retal space. New 400 Amp service, total connected load is less than 400 Amps. Adding new lighting and power. Total sq ft = 10560NOTE: Investigtion CE fee has been added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64468	18041-10001-15074	1234 W WILSHIRE BLVD	90017	1	130-5A207 637	5143019***	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Issued	06/25/2019 12:00:00 AM	ADDRESS	34.05329	-118.26612	NEW METHOD IN SUPPLYING THE 20 EV CHARGE STATIONS- 400A PANEL EV1B REPLACE WITH PANELS EV2 AND EV3 TO SUPPLY 10 EV CHARGERS; THE REMAINING 10 EV CHARGERS ARE SUPPLIED FROM FEED-THRU 400 PANELS EVIA and EVIB. REARRANGED SWITCHBOARD AND CMU WALL INSIDE THE ELETRICAL ROOM (((INSTALL 20 EV CHARGING STATIONS ON TWO PARKING LEVELS IN A HIGH RISE BUILDING.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64469	18041-10000-18951	1001 S CROCKER ST	90021	14	124-5A211 211	5132011044	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Issued	05/22/2018 12:00:00 AM	ADDRESS	34.03489	-118.25066	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 3000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64470	10041-20000-09212	2107 W WASHINGTON BLVD 1st Floor	90006	10	126B193   850	5074019003	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	05/26/2010 12:00:00 AM		Permit Finaled	08/16/2010 12:00:00 AM	PIN	34.04029798	-118.30633527	Plan check T-24 general/emergency lighting for Ray Charles Memorial Library on 1st floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64471	13041-10000-23590	890 N TOYOPA DR	90272	11	126B129    71	4411001013	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.04436	-118.52418	TITLE 24 PLAN CHECK ONLY.  3402 SQFT. EMERGENCY LIGHTING. 2 STORY BUILDING. WORK ON BOTH FLOORS. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64472	14041-20000-15825	12001 W CHALON ROAD 304a-b-305a-e	90049	11	141B141     5	4429003027	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.08469	-118.4849	Tittle 24 plan check only on an area of 2510 SQ feet inside a commercial building unit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64473	14041-20000-24795	7000 S HOOVER ST Unit #2	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #2.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64474	10041-30000-02038	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020030	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.20	Electrical	Electrical	Commercial			02/04/2010 12:00:00 AM	03/23/2010 12:00:00 AM		Permit Finaled	05/17/2010 12:00:00 AM	ADDRESS	33.79072	-118.29449	T. I. on the 3rd Floor of a medical office bldg, energy and (3) ckts plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64475	14041-10001-04146	5372 E TEMPLETON ST	90032	14	142-5A237 174	5219015016	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			Reviewed by Supervisor	03/06/2014 12:00:00 AM	ADDRESS	34.08492	-118.16613	Expediting RSES plan check per applicant request.{{PV1, Install 3.25 kW DC roof-mounted solar array on a two-story home, interconnect with existing service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (13) Modules: CANADIAN SOLAR CS6P-250PX.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64476	16041-20001-29387	1021 N KAGAWA ST	90272	11	129B129   560	4423010020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM			PC Approved	08/31/2016 12:00:00 AM	ADDRESS	34.04844	-118.51837	RSES expedited plan check fee per applicant request. PV1.  Install 5.85 kW DC roof mounted utility interactive system with battery backup (Tesla Powerwall).  SolarEdge 7600 W inverter with (18) modules regulated by power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64477	13041-10000-22881	1985 E ZONAL AVE 4TH FLOOR	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Approved	08/22/2013 12:00:00 AM	ADDRESS	34.06159	-118.20463	PLAN CHECK FOR TITLE 24 PART 6 ENERGY IN PHARMACY SCHOOL. HIGH RISE. EMERGENCY LIGHTING AND EXIT SIGNS ARE NOT IN SCOPE OF NEW WORK. PERMIT HAS BEEN OBTAINED UNDER APPLICATION NUMBER 13041-10000-22563.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64478	15041-20002-01610	15943 W GRESHAM ST	91343	12	195B141   406	2672024013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2015 12:00:00 AM			PC Approved	02/23/2015 12:00:00 AM	ADDRESS	34.23112	-118.47994	"Changes to an approved set of plans. Changes include the increase of a #8 grounding conductor to a #6 going from the inverter to the load center, and the removal of a #8 ""additional ground"" running from the inverter to the existing ground rod. *****Previous Work Description*****EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 8.4kW (4.2+4.2). Ungrounded system.28  327W pv modules across 4 strings (2 per inverter).]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64479	18041-10000-40444	7870 N NOLLAN PL	91402	6	189B153   988	2212028901	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.2146	-118.44491	PLAN CHECK FOR EV CHARGING STATIONS (3 LEVEL TWO CHARGERS AND 1 DC FAST CHARGER) CONNECTED TO EXISTING 2000A DISTRIBUTION SYSTEM-CONNECTED LOAD ABOUT 129A USING 800A EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64480	14041-20001-03778	4711 N BIZET PL PV1	91364	3	168B097   402	2074027037	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.15671	-118.62665	][]EXPEDITED PER APPLICANT REQUEST ][[]PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (N) 225A MAIN SERVICE PANEL. 10.25 kW DC SYSTEM, AND IS TRANSFORMERLESS, USING POWER OPTIMIZERS, WITH (41) TRINA SOLAR #TSM-250PA05.18, (41) OP300-MV, (2) INVERTERS, SE5000A-US-ZB-U SOLAREDGE AND SE3800A-US--ZB-U, (1) 125A LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64481	17041-10000-46196	1515 W 190TH ST #155	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	33.85852	-118.30531	PC FOR TENANT IMPROVMENT TO THE (E) OFFICE FOR TITLE 24 ENERGY ONLY.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 2772 SQ.FTTHIS IS PLAN CHECK ONLY!ELECTRICAL PERMIT PULLED UNDER 17041-10000-44964B#17016-20000-36392	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64482	19041-10000-52622	11122 N BALBOA BLVD	91344	12	210B133   327	2682021032	C4-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	04/30/2021 12:00:00 AM		Permit Closed	10/19/2022 12:00:00 AM	ADDRESS	34.27283	-118.50196	NEW GYM. INSTALL A NEW 1000 AMP SERVICE, PANELS, TRANSFORMER, CIRCUITS & LIGHTS. AFFECTED AREA: 21,137 SFT. BULDING PERMIT: 19016-10000-40542	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64483	12041-10000-05948	500 S VIRGIL AVE #301	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	NEW MEDICAL OFFICE SUITE #301.  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64484	16041-10000-03746	1532 W 11TH ST	90015	1	129A203   285	5137020020	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.04726	-118.27438	FULL PC FOR POWER AND ENERGY TO AN (E) COMMUNITY CENTER. SCOPE INCLUDES UPDGRADING THE MAIN SWITCHBOARD TO 800A 120/208V 3PHASE 4 WIRE, AND ADDING NEW PANELS AND LOADS. TOTAL AFFECTED AREA IS 39,362 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64485	16041-10003-45800	802 S FRIES AVE	90744	15	024B205    34	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			09/04/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	33.76172	-118.26356	"PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REDUCING OCPD TO 250A ON MNHV2, AND REDUCING CABLE SIZE(4/0AWG - 5KV TYPE MV105) - INSPECTION TO VERIFY 90 OR 105 DEGREE ""C"" LUG RATING ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64486	16041-20000-36387	3311 W SAN FERNANDO ROAD	90065	13	153B209   120	5458007012	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.11792	-118.24864	remove existing hid fixtures and replace with new led fixtures outdoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64487	17041-10000-06179	810 E PICO BLVD B07, B08	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	03/06/2017 12:00:00 AM		Issued	03/06/2017 12:00:00 AM	ADDRESS	34.03119	-118.25079	PC FOR ENERGY ONLY. TI  IN COMMERCIAL BUILDING @ UNITS B07 & B08. CONNECTED LOAD< 400A . TOTAL AREA 1814 SQ FT. B#17016-10000-03491	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64488	12041-10001-13171	16952 W BLANCHE PL	91344	12	219B133   513	2609026025	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	34.2955	-118.50128	Modification to use different  pv modules.            <<<New 11.04kw rooftop mounted PV system for an existing single family residence.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64489	14041-10000-01381	860 S BROADWAY 1st floor	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.04235	-118.2558	pc for energy only. permit to be pulled at EPC counter only. hirise (inspector to verify if generator present).TI to (E) retail. emergency lighting is existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64490	17041-20000-01682	6431 N INDEPENDENCE AVE	91367	3	180B109   592	2149003039	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.18737	-118.59079	Plan check for installation of solar pv system, roof-mounted on commercial building.  Interconnect with 400A MSP.  Derating main to 225A. 60kW ungrounded system (4*15kW).  (222) 275W PV modules.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64491	19041-10001-13642	17538 W LORNE ST	91325	12	189B129   270	2201004010	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	PIN	34.21697139	-118.51571266	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS RELOCATION SOLAR PANEL, NO NEW MODULES WERE ADDED. ALL CHNAGES ARE CLOUDED UNDER DELTA 1ORGINAL SCOPE OF WORK----------------------------------------ROOFTOP INSTALLATION ON EXISTING SFD TO FEED DETACHED ADU. SYSTEM SIZE IS 2.17KW DC/1.68KW AC/1.93KW AC CEC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES 310W AND (7) ENPHASE IQ 6 MICROINVERTERS 240W.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64492	13041-10001-01855	6222 W SANTA MONICA BLVD	90038	13	144B189   698	5534022033	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			08/26/2013 12:00:00 AM			PC Approved	08/26/2013 12:00:00 AM	ADDRESS	34.09053	-118.32534	(((CHANGES TO APPROVED SET OF PLANS: INSPECTOR REQUEST: SHOW (E) 400A PANEL THAT SERVES BOTH BUILDINGS)))electrical permit to be pulled at plan check onlyenergy plan check with emergency lighting less than 400 Aaddition: PROPOSED NEW 2-STORY OFFICE BUILDING (SHELL BLDG)..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64493	08041-10004-15884	255 S HILL ST Bldg A,B,C	90012	9	130-5A211  15	5149010264	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Apartment			07/08/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	05/10/2011 12:00:00 AM	ADDRESS	34.05197	-118.24904	Replace lighting in the corridors and common areas of three high rise apartments (Building A, B & C are under one building permit), add a microwave receptacle in each residential unit and replace two cooling tower fans in building C.  Power and energy.Note: the fan coil units for all residential units are not going to be replaced as is shown on the original plans, a supplemental plan check revised the replced fc units with existing fc units.Additional ckts and panels and xfmr. 7-8-10.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64494	13041-20000-07993	21029 W OSBORNE ST	91304	3	195B105    42	2779048008	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.23316	-118.59177	T-24 lighting plan check for a new temperature controlled room inside of an existing warehouse.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64495	13041-20000-27560	14400 W ARMINTA ST	91402	6	189B149   664	2212001015	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.21259	-118.44646	T24 FOR AUTOMATIC DAY LIGHT CONTROLS AND INSTALLING EM LIGHTS ONLY. POWER CHECKED ON APPLICATION#: 13041-20000-28015	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64496	17041-10000-02762	1011 S LOS ANGELES ST 4th Floor	90015	14	126A209   145	5139015005	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.03944	-118.25641	Plan check for Title 24 only indoor lighting, in existing space replace HID fixtures with new LED fixtures. Total area: 4,350 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64497	14041-10001-24468	5212 N DAHLIA DR	90041	14	163-5A227 204	5669012001	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Corrections Issued	09/20/2014 12:00:00 AM	ADDRESS	34.14214	-118.19965	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 9.945 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(39) MODULES: KYOCERA  KD255GX-LFB3(2) INVERTE(S): SOLAREDGE SE6000A-US-ZB-U & SE3000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64498	17041-20000-41873	11894 N WHEELER AVE	91342	7	216B165    49	2531033021	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.28659	-118.39843	Plan check for solar pv system w/roof-mounted array for SFD. Center-fed panel.3.8kW ungrounded system. (14) 285W pv modules. (14) 320W power opimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64499	19041-10000-53834	660 S MYERS ST	90023	14	124-5A219 106	5171021031	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.03619	-118.22501	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64500	19041-10000-05338	21521 W BLYTHE ST	91304	3	189B105   241	2110005027	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.21463	-118.60041	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64501	19041-10000-46998	111 E UNIVERSAL HOLLYWOOD DR 4TH;9TH-FLOORS	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00, 3200.00	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM			PC Approved	11/14/2019 12:00:00 AM	ADDRESS	34.13855	-118.36112	ALTERATIONS IN RESTROOMS ON THE 16TH; 20TH; 25TH FLOORS OF OFFICE BUILDINGPLAN CHECKIS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64502	14041-20000-16684	20531 W RHODA ST	91367	3	174B109   298	2151022042	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Expired	08/05/2016 12:00:00 AM	ADDRESS	34.17398	-118.58098	PV1Install roof-mounted solar array on SFD. System size: 5kW(1) SolarEdge #SE5000A-US-ZB-U transformerless inverter(26) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64503	17041-20001-00349	1925 S LELAND ST	90731	15	012B193   989	7460027026	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2972.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2017 12:00:00 AM			PC Approved	01/20/2017 12:00:00 AM	ADDRESS	33.72653	-118.30135	expeditepv1install roof mounted pv system sized 5kw interconnected ith msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64504	13041-10000-07549	6201 W HOLLYWOOD BLVD	90028	13	148-5A189 350		[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.1018	-118.32461	New fire alarm system for 6 story building over 5 levels of subterenean parking. 487 devices 1 fire alarm panel and 1 annunciator. (pLAN UNDER SUBMITTA 2 INCLUDES FOUR BUILDING ALONG WITH PARKING, FEES COLLECTED FOR 3500 MORE DEVICES UNDER PCIS SUBMITTAL 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64505	15041-20002-07437	12914 W WINGO ST	91331	7	201B161   368	2624010017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM			PC Approved	05/06/2015 12:00:00 AM	ADDRESS	34.24934	-118.414	5/5/2015 Changes to an approved set of plans. Changes have been made to the PV module layout and to the string length. System size has remained the same.*****Previous Work Description*****Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64506	18041-10000-06316	10250 W SANTA MONICA BLVD 2000	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR THEARTE AUDITORIUM INTERIOR RENOVATION (PLACE OF ASSEMBLY). SCOPE OF WORK INCLUDES A/V UPGRADES,  LIGHTING, RECEPTACLES AND EQUIPMENT.  Total affected area 4462 sq.ftB#18016-10000-05277	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64507	12041-20000-26331	15233 W VENTURA BLVD	91403	5	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	11/02/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.1538	-118.46502	Change to lighting and receptacles in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64508	12041-10000-19683	621 S WESTERN AVE	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TIME TENAT IN COMMERCIAL SPACE ( 214 )-FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64509	12041-10000-08391	445 S TOWNE AVE 3rd-4th Floor	90013	14	127-5A213 314	5147009001	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM			PC Approved	07/12/2012 12:00:00 AM	ADDRESS	34.04334	-118.2419	Plan check for T24 Energy/Emergency lighting for 3rd restroom remodel and 4th floor restroom and common areas. 4th floor is R1 type occupancy, dormitory rooms excluded from T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64510	12041-10001-09131	5722 W MELROSE AVE	90004	4	141B189   339	5523012001	C1-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/15/2012 12:00:00 AM	PIN	34.08334206	-118.32450625	PLAN CHECK FOR T24 ENERGY FOR NEW LIGHTING IN EXISTING DINING AND RESTROOM. EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64511	13041-10004-16473	750 S LAMAR ST gate bldg	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM			PC Approved	05/03/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	PLAN CHECK FOR TITLE 24 ONLY FOR SIGN PERMIT. ORIGINAL PERMIT RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (1.) existing gate building modifications  (lighting modifications) BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64512	17041-20001-31426	3930 S WISCONSIN PL	90037	8	117B197   954	5037019007	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.01453	-118.29323	10/13/2017 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the rating of the MSP.*****Previous Work Description*****PC FOR ROOF MOUNTED PV SYSTEM ON SFD. SYSTEM SIZE 3.36 KW AC  4.06 KW DCSCOPE INCLUDES 14 MODULES WITH 14 MICRO INVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64513	11041-10000-21206	10000 W PICO BLVD BLDG 1	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00, 2691.00, 2695.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	11/02/2012 12:00:00 AM	ADDRESS	34.05211	-118.40654	BLDG. NO. 1(Pool equipment section inc. outside lighting) OF POOL HOUSE AT THE HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDG. NO. 1, 2, 3, & 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64514	14041-20002-15000	19325 W ROMAR ST	91324	12	204B117   307	2726017001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM			PC Approved	07/16/2014 12:00:00 AM	ADDRESS	34.25551	-118.5546	Change from previously approved plans.  Change in relocating PV modules on roof.  No change in model number and system size.Note: Permit is under the original application.  Plan check is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****New roof mounted PV system with transformerless inverters.  Total system size 11KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64515	16041-10000-44875	368 E 2ND ST	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.04797	-118.2399	Plan check for Title 24 only in existing space restaurant. Total area: 1347 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64516	13041-10000-07877	22228 W MARILLA ST	91311	12	201B101   304	2727006008	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.24746	-118.61156	PV1 ONE STORY SINGLE FAMILY DWELLING. TRANSFORMERLESS INVERTER. TOTAL SYSTEM SIZE: 13.92 KW WITH 49 MODULES AND 2 INVERTERS. [INVERTER 12): POWER ONE AURORA PVI-6000-OUTD-US | | INVERTER (1): POWER ONE AURORA PVI-3.6-OUTD-US] [SOLAR MODULE: TRINA SOLAR TSM-240-PA05.10]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64517	19041-30000-52025	10100 W SANTA MONICA BLVD #1300	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.06191	-118.41691	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFCTED AREA IS 1595 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64518	19041-10000-34004	1771 W BLAKE AVE BLDG 6	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Corrections Issued	10/02/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	6 OF 11. BLDG 6POWER PLAN CHECK FOR 800A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDINGS AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64519	15041-20000-19308	20756 W CHATSWORTH ST	91311	12	207B109   349	2706011017	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Expired	07/18/2017 12:00:00 AM	ADDRESS	34.26425	-118.58632	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 7.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64520	19041-10000-33617	6310 W SAN VICENTE BLVD 400	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM	ADDRESS	34.06084	-118.36757	PLAN CHECK FOR ENERGY ONLY, TO A TENANT IMPROVEMENT FOR COMMERCIAL OFFICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1938.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64521	19041-20000-19319	2245 W LOMA VISTA PL	90039	13	147A209   431	5422009021	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Issued	05/22/2019 12:00:00 AM	ADDRESS	34.09524	-118.25609	Plan check for a PV1 roof-mounted PV system. System size is 3.78 kWdc/3.4713 kWac-CEC and consists of (1) 3.8 kWac-rated inverter, (12) modules, (2) load centers, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64522	17041-20000-28029	5657 N BELLINGHAM AVE	91607	2	174B165   510	2340024024	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.17382	-118.39882	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64523	18041-10000-39614	1518 N CAHUENGA BLVD	90028	13	147A187    77	5546012007	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	11/09/2021 12:00:00 AM	ADDRESS	34.09857	-118.32936	NEW 2 LEVEL OFFICE BUILDING WITH A NEW 800 AMP SERVICE. 8216 SQR FT. PLAN CHECK FOR POWER AND ENERGY. BULDING PERMIT: 17016-10000-38014	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64524	14041-20000-18058	9757 N DELCO AVE	91311	12	201B109   175	2748011039	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/19/2014 12:00:00 AM	ADDRESS	34.24796	-118.57897	pv1 single family dwelling. total system size 3.8 kw ac using 14 modules. using transformerless inverter with power optimizers. nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64525	15041-20000-43169	6200 N KESTER AVE	91411	6	178-5A149 198	2241016013	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			12/24/2015 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.1828	-118.4573	FULL PC FOR A NEW KESTER 4-STORY 22-UNIT APARTMENT BUILDING OVER A BASEMENT GARAGE. TOTAL AFFECTED AREA IS 16819 SQ. FT.Note: Building application has been created under 15010-20000-03289	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64526	10041-10000-09922	23130 W SHERMAN PL 1A	91307	3	183B097   888	2026001907	(Q)CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Public Safety Only			05/25/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	ADDRESS	34.2006	-118.63019	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64527	13041-10001-33020	12237 N CRYSTAL HILLS WAY	91326	12	219A117   136	2701013028	RD3-1, RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch		1082.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.29569	-118.56257	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 6 KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(24) TRINA SOLAR # TSM-250(24) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE6000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64528	16041-20002-44615	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	08-28-2019 Changes to an approved set of plan, Changes include remove lighting fixtures all Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64529	14041-20000-04053	20244 W VIA GALILEO	91326	12	219B113   173	2701043009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Expired	04/06/2016 12:00:00 AM	ADDRESS	34.29486	-118.57509	Install new roof mounted PV system with 6.25KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64530	13041-20000-09682	14141 W VENTURA BLVD # 100	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM	07/05/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	First time tenant in suite 100.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64531	17041-30000-37793	1109 S CARDIFF AVE	90035	5	132B169   509	4332002060	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			10/19/2017 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.05675	-118.39192	Plan check for new Fire alarm system for 21 units appartment building. Total fire alarm devices: 121 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64532	19041-20000-15546	1999 S AVENUE OF THE STARS Suite 3250	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	09/17/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only. Project site is a portion of the 32nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,931 sq. ft.Note: Building permit has been issued under 19016-40000-09632	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64533	12041-10000-27436	5338 E BALTIMORE ST	90042	1	154-5A227 287	5478017069	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1835.10	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	02/19/2013 12:00:00 AM	ADDRESS	34.11725	-118.19999	PV1 SOLAR INSTALLATION 2.45 KW. ROOF MOUNTED. ENPHASE MICROINVERT STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64534	15041-20000-43110	5510 S LINCOLN BLVD STE 220	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	33.97299	-118.43051	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON SUITE 220 (OFFICE/CONFERENCE SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 590 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64535	18041-10000-08047	9500 N DE SOTO AVE	91311	12	198B109    24	2748023044	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.24311	-118.58831	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 4595 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64536	16041-20000-32797	12751 W MILLENNIUM #115	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Change of use from retail to dance studio.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64537	19041-20000-53512	1355 N VINE ST BLDG. B-FL 2-5	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	07/01/2020 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.0956	-118.32685	"FIRST TIME TENANT INTERIOR  IMPROVEMENTS TO BUILDING ""B"" (NETFLIX) ON LEVELS 2 THROUGH 5. PLAN CHECK FOR POWER AND ENERGY. AFFECTED AREA: 103,483 SFT. T-24 ENERGY PLAN  BUILDING PERMIT: 19016-10000-28207"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64538	16041-10000-30987	5760 W ARBOR VITAE ST	90045	11	093B169   344	4125020014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Issued	09/13/2016 12:00:00 AM	ADDRESS	33.9525	-118.38238	Plan check for Title 24 only new storage canopy. Outdoor lighting area: 4,192 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64539	18041-30000-48958	601 S FIGUEROA ST Suite 4275	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is a tenant suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,335 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64540	16041-20003-42753	9182 N KELVIN AVE	91311	12	198B109   125	2748036008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM			PC Approved	03/09/2017 12:00:00 AM	ADDRESS	34.23802	-118.58526	[[ 3/9/17 CHANGES TO APPROVED SET. DELTA 2 CHANGES. CHANGES ARE CLOUDED. CHANGING SOLAR LOAD CENTER BREAKERS TO 40 AMPS EACH BASED ON INVERTER OUTPUT OF 27.3 AMPS. CHANGING AC 1, AC2 FEEDER.]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64541	19041-10000-37233	888 S FIGUEROA ST #900	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Issued	11/01/2019 12:00:00 AM	ADDRESS	34.0465	-118.26225	ENERGY PC FOR PROPOSED NON-STRUCTURAL T.I. TO OFFICE SPACE; AREA OF SCOPE 10,531SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64542	13041-10000-05848	1555 N GORDON ST	90028	13	148-5A191 299	5545007019	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.09966	-118.31978	MODIFICATIONS TO APPROVED SET OF PLANS (DELTA 4 REVISIONS). ORIGINAL APP NUMBER 11041-10000-22232. CHANGES MADE TO T24 FOR THE 4-STORY APARTMENT BUILDING FOR EXTERIOR AND CORRIDOR LIGHTING. PERMIT ISSUED UNDER 11041-10000-22232 BOTH SETS TO BE KEPT TOGETHER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64543	15041-20000-10142	5860 W JEFFERSON BLVD	90016	10	120B173  1729	4205027022	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM			PC Info Complete	06/02/2015 12:00:00 AM	ADDRESS	34.02504	-118.37633	Plan check for T-24 only for new parking lot. Total area: 200, 989 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64544	15041-10000-34789	707 W WILSHIRE BLVD STE 4375	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  THIS IS PLAN CHECK ONLY.  PERMIT FEES PAID UNDER APPL# 15041-90000-30372Small TI on the 43rd floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64545	14041-10000-12744	1868 S KELTON AVE 1-24	90025	5	129B153   811	4323006015	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.04756	-118.43747	NEW FIRE ALARM SYSTEM FOR 24 UNIT APARTMENT BUILDING. 124 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64546	11041-20000-03750	13760 W RIVERSIDE DR	91423	2	168B153   929	2269025***	(Q)PB-1L, C2-1L, P-1L, QC2-1L, QPB-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Public Safety Only			02/28/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	04/06/2011 12:00:00 AM	ADDRESS	34.15637	-118.43331	Plan check for new fire alarm system at Sports Authority retail store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64547	18041-20001-13073	14753 W AETNA ST	91411	6	177A149    72	2241025006	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.18022	-118.45479	"SUPPLEMENTAL PLAN CHECK ONLY CHANGE TO APPROVED SET. DELTA 2 CLOUDED CHANGE ONLY. CLARIFICATION TO PANEL LT LOAD*original 18041-10000-13073*T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES DUE TO FIRE DAMAGE. TOTAL AFFECTED AREA IS B#17016-30000-29501""COMPLY WITH DEPARTMENT ORDER effective date 06/23/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64548	19041-10000-32902	1800 N HIGHLAND AVE	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM			PC Info Complete	09/11/2019 12:00:00 AM	ADDRESS	34.10436	-118.33763	Energy plan check for offices T.I. Scope include new lighting and equipment located in the 4th and 6th floor of a high rise building. Total area is 20,758-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64549	19041-20000-35956	640 N LAS LOMAS AVE	90272	11	129B121   819	4414013009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.04692	-118.53922	INSTALL (2) TESLA POWERWALLS TO EXISTING PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64550	13041-10000-25346	717 S BERENDO ST 1-34	90005	10	132B197   298	5094009013	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			09/13/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.05917	-118.29429	FIRE ALARM PANEL REPLACEMENT AND INSTALLING ONE SMOKE DETECTOR. OTHER DEVICES ARE EXISTING TO BE REMAINED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64551	14041-20000-14046	20750 W VENTURA BLVD SUITE 105	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.16638	-118.58506	TI to (E) commercial office space of existing 4-story commercial office building.  Plan check for changes to lighting system for Title 24 Part 6 compliance.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64552	16041-30000-17309	4354 W SANTO TOMAS DR	90008	8	114B181    92	5031001002	[Q]RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01124	-118.34845	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft. Note: Building application has been generated under 16010-30000-01099	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64553	18041-20000-42732	238 S LUCERNE BLVD	90004	4	135B189    73	5515021007	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/25/2019 12:00:00 AM	ADDRESS	34.0699	-118.32465	PV1.  Install roof mounted PV system sized 9.1 kW interconnected with MSP, with battery 10 kWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64554	18041-20000-25202	12727 W SHERMAN WAY	91605	2	183B161    11	2324004004	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM			PC Info Complete	10/02/2018 12:00:00 AM	ADDRESS	34.20137	-118.41091	Plan check for power only. Service upgrade to 5,000A 480/277Volt distribute to existing switchgear to multiple commercial B occupancy building..refer to comments...............	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64555	14041-20000-10974	10331 N BEVIS AVE	91345	7	204B149   152	2648008028	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.25845	-118.4555	PV1 INSTALL ROOF MOUNTED PV SYSTEM WITH POWERBOX OPTIMIZERS, SYSTEM SIZED 7.5KW INTERCONNECTED WITH MAIN PANEL.  (2) SOLAREDGE TRANSFORMERLESS INVERTERS 3.8KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64556	19041-20000-49033	13114 W RATNER ST	91605	2	189B157   292	2304021006	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Issued	11/27/2019 12:00:00 AM	ADDRESS	34.21659	-118.41962	PV1.  Install 3.2 kW DC roof mounted grid tied PV system.  (10) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64557	16041-10001-41389	13859 W RUNNYMEDE ST	91405	2	186B153   246	2215007001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2016 12:00:00 AM			Reviewed by Supervisor	12/06/2016 12:00:00 AM	ADDRESS	34.20585	-118.43538	EXPEDITE PER APPLICANT REQUESTPV, NEW 11.2 KW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE WITH DETACHED GARAGE. (40) MODULES: SUNIVA OPT280-60-4-1B0(40) MICROINVERTERS: ENPHASE M250-60-2LL-S22PLAN CHECK ONLY. PERMIT WAS PULLED UNDER # 16041-10000-32076	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64558	19041-20000-52802	1921 N WILCOX AVE	90068	4	150A187   154	5575002019	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM			Reviewed by Supervisor	01/31/2020 12:00:00 AM	ADDRESS	34.10582	-118.33103	Plan chek for power and energy for 1200A Service, 100KW Generator, 3 ATS(Emergency, Legally Required, and Optional Standby), Total area: 86,053 sq ft. B#19010-10000-02914************Building Work Description***************************MAJOR ADDITION AND CHANGE OF USE TO (E) BUILDING TO  HOTEL 122 GUEST ROOMS WITH RESTAURANT AND POOL WITH BASEMENT GARAGE.   3 STORY OF TYPE III-A OVER 1 STORY  TYPE ***********************************************************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64559	11041-10000-16758	6902 W SANTA MONICA BLVD	90038	4	144B181   478	5532029013	MR1-1	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	08/09/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.09049	-118.34078	Fire alarm system for voice over studio.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64560	17041-30000-10261	8258 N HAVEN LANE	91325	6	192B133   533	2204001047	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.22078	-118.50722	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64561	14041-10000-00616	1100 S SAN PEDRO ST # E-13	90015	14	124-5A211 343	5132011237	M2-2D	Central		Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.03515	-118.25194	T24, for a commercial building, changing light fixtures  with existing circuits, Total area 560 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64562	12041-10001-07640	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	"Modification to previously approved set of plans to separate installation into two phases.  This phase will install panel ""1LPD"" and xfrmr ""T-3"".  Loads are calculated based on values from the main application.       <<<<<Plan check power for LAX Terminal 5 Primary switchgear and distribution (infracture upgrade). New equipment, switchboards, and panels. Existing service.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64563	10041-10000-01159	15825 W ROXFORD ST	91342	7	222B141    96	2604002037	M1-1, P-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM	01/22/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.30457	-118.47839	Plan check for power on replacing emergency generator and ATS switch.  All loads in electrical system are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64564	11041-20000-16617	400 N AMALFI DR	90402	11	123B129   407	4408024005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	PIN	34.03348463	-118.51468437	PLAN CHECK NEW 2-STORY SFD W/ATTACHED GARAGE WITH 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64565	10041-20000-10026	9848 W TABOR ST 1-61	90034	10	120B165   220	4313011026	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2701.00	Electrical	Electrical	Apartment			05/26/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	05/11/2011 12:00:00 AM	ADDRESS	34.02786	-118.40159	Plan check installation of 18.1KW photovoltaic sytem for apartment complex.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64566	12041-10000-28619	1501 N SAN PABLO ST 5th floor	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			11/28/2012 12:00:00 AM			PC Approved	11/28/2012 12:00:00 AM	ADDRESS	34.06263	-118.20329	TENANT IMPROVEMENT OF RESEARCH LABORATORY SPACE ON THE 5TH FLOOR OF THE EXISTING ZILKHA NEUROGENETIC INSTITUTE BUILDING.  NO CHANGE OF USE.PLAN CHK IS FOR TITLE 24 (LESS THAN 400A  added)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64567	15041-10000-43342	9045 S LINCOLN BLVD B-LV	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.95667	-118.4165	T-24, TI IN AN (E) ART SCHOOL BUILDING, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN CLASSROOMS ON THE BASEMENT LEVEL. TOTAL SQ. FT. 7068.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64568	10041-10000-07427	3831 S HUGHES AVE #702	90232	10	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.02242	-118.39823	TI IN AN EXISTING MEDICAL OFFICE AREA ON THE 7TH FLOOR IN SUITE# 702.  PLAN CHECK IS FOR POWER.  TITLE  24 ENERGY CALCS AND EMERGENCY LIGHTS WAS SUBMITTED AND APPROVED  AND OBTAINED PERMIT BY APPLICATION NUMBER 09041 30000 20245.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64569	16041-30000-28594	2049 S CENTURY PARK EAST 25th Floor-Lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Issued	08/11/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check Title 24 only in existing high-rise elevator lobby 25th Floor. Total area: 330 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64570	18041-20001-16725	11350 N GLENOAKS BLVD	91331	7	213B161   844	2533028002	RA-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.27695	-118.41486	Expedite per applicant requestPlan check for PV roof mounted system commercial space, system size: 43kWac with 126 modules and 3 inverters(14.4kW) connected to 800A existing switch gear.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64571	15041-10004-14231	600 WORLD WAY Terminal 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM			PC Approved	09/21/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	9/21/15: T-24. Changes to an approve set. Changes to lighing fixtures on delta C. ((8/25/15: Supplemental, changes on light fixtures))(T-24 FOR TWO KITCHEN SPACES IN LAX, TOTAL SQ. FT. 1190)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64572	18041-20002-24822	5757 W WILSHIRE BLVD #P2	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.06259	-118.35341	Revisions to approved set.  Delta-5 revisions only.  Relocations of medical gas and vacuum pump.  (((Plan check for power and energy for outpatient medical office space with operating room. Total area: 1827 sq ft. Modification filed to complete 30-day existing demand reading and resubmit to plan check. Building permit filed under 18016-20000-19914.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64573	14041-20000-01508	309 E 8TH ST Levl 4, 5,-6	90014	14	126A211    30	5145003009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.04121	-118.25128	T.I. to existing building.  Convert level 6 to core and shell.  Install general/emergency lighting in common areas for levels 4, 5, and 6.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64574	16041-10001-38362	7029 W WILLOUGHBY AVE	90038	4	144B181   803	5532010041	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Closed	04/09/2018 12:00:00 AM	ADDRESS	34.08719	-118.34253	supplemental to changes to approved set of plan - changes include addition of 2 new water heaters relocation of receptacles and outdoor lighting with title 24. total ourdoor affected area = 848 sq. ft. changes are clouded under delta 1. Plan check for Power only, service upgrade from 200A to 800A due to change from one tenant to multiple tenant in an (E) one story commercial building.  Located on Methane Buffer zone	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64575	15041-10000-02475	20316 W SATICOY ST	91306	3	186B113   228	2114007003	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	Apartment			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.20818	-118.57584	Replacing a new compatable fire alam panel for an existing alarm system.  applicant also add on (2) power supplies, (1) detector and (2) mini horns.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64576	17041-10001-42171	700 S FLOWER ST STE 2990	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR CHANGES TO APPROVED SET PER INSPECTION UNDER DELTA 2.SCOPE INCLULDES CHANGES TO EM. LIGHTS LOCATION TO REFLECT EXISTING CONDITIONS. T-24 REVISED TO REFLECT THESE CHANGES. THIS IS PLAN CHECK ONLY!PC FOR TI TO (E) OFFICE SPACE FOR TITLE 24 ENERGY ONLY!SCOPE INCLUDES NEW LIGHTS, RECEPTACLE AND EQUIPMENT. TOTAL AFFECTED 3282 SQ. FT.PARTIAL PERMIT FEES PAID UNDER 17041-90000-45052 (FOR 38 CIRCUITS AND PANEL)B#17016-30000-26261	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64577	18041-20000-28013	15541 W LANARK ST	91406	6	192B145   618	2654038013	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.21869	-118.47164	TI to an existing commercial building.  Adding (4) new panels HA, HB, TDBA1, TDBA2 to existing equipment.  Plan check for power only.  All other equipment existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64578	17041-10000-13539	2054 E JUDSON ST	90033	14	130-5A223 105	5175021028	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2036.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.05303	-118.2088	Plan  check for  PV roof mounted system. System size: 3.8kW with12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64579	19041-20000-23048	4047 N FARMDALE AVE pv1	91604	2	162B169   387	2368025028	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.14125	-118.38128	pv1instll roof mounted pv system sized 7.6KW AC interconnecte dwith msp.(1) tesla ESS rated 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64580	18041-10000-45401	1127 N LAS PALMAS AVE	90038	4	144B185   681	5532021029	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/11/2022 12:00:00 AM	ADDRESS	34.0916	-118.33657	******FEE ESTIMATE ONly******PC FOR NEW 5 STORY (( AFFORDBALE HOUSE)) APARTMENT BUILDING (98 DWELLING UNITS WITH MORE THAN 13 TYPICAL UNIT). SCOPE INCLUDES EXISTING SERVICE AND SWITCHBOARD (1600A), NEW PANELS, EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 15300SQ.FT.((B# 16014-10000-05990))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64581	19041-10000-05059	11950 N ERWIN ST	91606	2	177B165  1101	2334011030		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/21/2023 12:00:00 AM	ADDRESS	34.18281	-118.39363	FULL PLAN CHECK FOR POWER AND ENERGY (BLDG ).   NEW 161 UNIT + 1 MODEL RESIDENTIAL APARTMENT BLDG, 4 STORY TYPE 111A CONSTRUCTION OVER TYPE 1A PARKING STRUCTURE.  WITH AMENITY SPACES, LEASING OFFICE, MAINTENANCE ROOM.  SERVICE SIZE IS 5000A, 120/208V WITH 20 TYP UNITS AND TOTAL AFFECTED AREA = 129795 SF.B#19010-10000-00592	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64582	13041-10000-35828	7855 N VAN NUYS BLVD	91402	6	189B149   493	2210022011	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			Verifications in Progress	09/02/2014 12:00:00 AM	ADDRESS	34.21362	-118.44897	pc for energy only. less than 400A . NEW COMMERCIAL BUILDING (1-STORY 2,055 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64583	16041-20002-30532	9210 N DORRINGTON AVE	91331	6	198B153   744	2642027009	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.23764	-118.4363	10/21/2016 Changes to an approved set of plans. System has changed from (2) central inverters to (35) AC modules.  Number of modules remains unchanged.  Additional subpanel in design - additional inspection fee paid for subpanel under this permit.  (((*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM . SYSTEM SIZE: 11.445 KW.Note: $0.00 permit fees due to Senate Bill 1222)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64584	12041-20000-06370	5141 N STANSBURY AVE	91423	4	171B153   503	2248022035	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2012 12:00:00 AM			PC Approved	03/20/2012 12:00:00 AM	ADDRESS	34.16407	-118.44119	Roof mounted 6.72KW PV system.Note: Permit issued under 12041-20000-03993	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64585	16041-20000-44514	8314 W 3RD ST	90048	5	138B173   892	5511031036	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	02/27/2017 12:00:00 AM		Issued	02/27/2017 12:00:00 AM	ADDRESS	34.07259	-118.37057	Title 24 plan check.  Total area = 340 sq. ft.T.I. to kitchen and service area in existing restaraunt.  200 amp subpanel to remain existing.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64586	17041-20000-30155	7943 N WOODLEY AVE	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.21559	-118.48387	Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size 960 kWac. Ground-mounted portion of the system is 180 kWac and consists of (3) inverters, (512) modules, and (1) load center.Note: Roof-mounted portion of the system has application number 17041-20000-30147.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64587	19041-20002-07133	414 S VIRGIL AVE	90020	13	136-5A201 298	5077001033	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM			PC Approved	06/12/2019 12:00:00 AM	ADDRESS	34.06632	-118.2869	PLAN CHECK ONLY. SUPPLEMENTAL CHANGES TO APPROVED SET. CHANGES TO ROOF LAYOUT AND RELOCATION OF ELECTRICAL EQUIPMENT. CHANGE IN AIC RATING ON SINGLE LINE. CLOUDED DELTA 1 CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64588	13041-10000-35113	"4433 S ALAMEDA ST BLDG ""A"""	90058	9	112-5A215  35	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.00295	-118.23924	T24 PART 6 ENERGY FOR (E) 33,410 SQ FT COMMERCIAL SPACE. RETRO-FITTING 4' FLUORESCENT LIGHT FIXTURES WITH NEW F54T5HO LAMPS. SCOPE OF WORK < 400A. PERMIT IS EXISTING. NO NEW/MOVED WIRING, LIGHTING PANEL INSTALLED/RELOCATED PER APPLICANT. SUBJECTED TO FIELD VERIFICATION IF SECTION 131 OF ENERGY CODE NEEDS TO BE COMPLIED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64589	18041-10000-04614	2201 S WESTWOOD BLVD	90064	5	126B157   400	4322002023	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM			PC Info Complete	02/16/2018 12:00:00 AM	ADDRESS	34.04357	-118.43169	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR WORK ONLY. TOTAL AFFECTED AREA 4000 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64590	17041-10000-16463	6607 N NEWCASTLE AVE	91335	3	180B125   428	2122029008	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.19062	-118.52542	PC FOR PV SYSTEM USING MICROINVERTERS ENPHASE M250. TOTAL OF 12 MODULES, SYSTEM SIZE 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64591	18041-20000-23844	14921 W OTSEGO ST	91403	4	171A149   150	2263005006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.16308	-118.45818	Plan check for a PV1 roof-mounted PV system. System size is 11.59 kWdc/10.5 kWac-CEC and consists of (1) 3 kWac rated inverter, (1) 7.6 kWac rated inverter, (38) modules, (2) Tesla PowerWalls, and (3) load centers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64592	14041-10000-13848	227 N LARCHMONT BLVD	90004	4	138B189   553	5515018017	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			Reviewed by Supervisor	07/02/2014 12:00:00 AM	ADDRESS	34.07544	-118.32384	PLAN CHECK FOR POWER FOR 600AMP SERVICE UPGRADE FOR EXISTING COMMERCIAL AREA WITH NEW SUBPANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64593	16041-20000-25650	660 S SANTA FE AVE	90021	14	124-5A217 128	5164018002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.03609	-118.23014	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR LYFT DRIVER CENTER. 4500 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64594	18041-20000-42095	1800 CENTURY PARK EAST mezz and-1st flr	90067										Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			PC Approved	11/02/2018 12:00:00 AM				ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64595	10041-20000-11402	22144 W CLARENDON ST # 270	91367	3	174B101   474	2169026074	(T)(Q)CR-2VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			06/15/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	07/19/2010 12:00:00 AM	ADDRESS	34.16941	-118.60982	INTERIOR T. I . ONLY FOR UNIT # 270  ( 2,865 SQ FT ). Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64596	11041-20000-17760	127 S SAN VICENTE BLVD Bulletin-92	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 92 plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64597	15041-10000-35848	11835 W OLYMPIC BLVD 1ST FLR	90025	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	PIN	34.03318579	-118.45141815	T-24, TI TO AN (E) LOBBY IN A HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2785.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64598	10041-20000-02943	13013 W SATICOY ST	91605	2	186B161   370	2303021015	CM-1, P-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			02/19/2010 12:00:00 AM	02/19/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.20715	-118.41638	warehouse, office remodelingEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64599	11041-20000-21873	5443 N MURIETTA AVE	91401	2	174B153  1150	2247009022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	11/17/2011 12:00:00 AM	ADDRESS	34.16989	-118.43908	roof mounted 5.76KW photovoltaic system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64600	14041-20001-26204	4433 N DEANWOOD DR	91364	3	165B113   107	2174024007	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM			PC Approved	09/23/2014 12:00:00 AM	ADDRESS	34.15017	-118.57477	expadite per customer request.pv1install roof mounted pv system sized 8.4kw interconnected with msp.(41) kyocera kd255gx modules(2) abb pvi-4.2-outd inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64601	12041-10000-25268	2727 W SAN FERNANDO ROAD	90065	1	150B213   224	5457007031	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM			PC Info Complete	10/22/2012 12:00:00 AM	ADDRESS	34.11011	-118.24246	PARTIONED A PART OF AN EXISTING WAREHOUSE TO BE A STORAGE AREAPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64602	16041-20001-01224	4956 N AGNES AVE	91607	2	168B165    13	2355009065	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.1609	-118.39522	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (64) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64603	16041-20000-16731	5535 W BODEN ST	90016	10	120B173   178	5048018011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.02775	-118.36719	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.48 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64604	18041-20001-22619	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.1937	-118.49152	Expedite per applicant request. Plan check for PV battery back roof mounted on commercial building, system size; 75kW with 265 modules and 3 inverters(30kW), (2) 30kW battery back up connected to  800A  Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64605	11041-10000-22230	1100 S FLOWER ST	90015	14	127-5A207 224	5138014015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/18/2011 12:00:00 AM			PC Approved	10/18/2011 12:00:00 AM	ADDRESS	34.04273	-118.26409	T.I. to an existing office building.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64606	18041-10000-37757	914 E 31ST ST	90011	9	117A209   109	5114021043	(Q)M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.01573	-118.25941	NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (660) MODULES, (6) 33.3KW INVERTERS AND (330) POWER OPTIMIZERS P700. TOTAL SYSTEM SIZE IS  199.8KWAC/217.8KWDC.$0 fees due to senate Bill1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64607	11041-20000-15299	11444 W OLYMPIC BLVD 3rd Floor	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.03654	-118.44363	T24 ENERGY AND EMERGENCY FOR T.I. OF EXISTING OFFICE BUILDING ON 3RD FLOOR. PERMIT FOR NEW CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64608	13041-20000-17751	10136 N GERALD AVE	91343	12	204B137   609	2685016009	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.25505	-118.49459	PV1 SINGLE  FAMILY DWELLING. SYSTEM SIZE 5.2 KW. USING TRANSFORMERLESS INVERTER. 3 STRINGS. NONSTANDARD PLAN. TOTAL OF 15 MODULES. PERMIT INCLUDES MAIN SERVICE AND PANEL UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64609	15041-20000-13500	1539 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.09892	-118.327	PC FOR T24 ENERGY ONLY. NEW LIGHITNG IN RESTAURANT. TI TO EXISTING RESTAURANT. NEW TENANT 800 DEGREES. LESS THAN 400A LOADS. LESS THAN 100 OCCUPANTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64610	14041-20000-27701	20810 W NORDHOFF ST	91311	3	198B109   193	2780001023	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM	05/08/2015 12:00:00 AM		Issued	05/08/2015 12:00:00 AM	ADDRESS	34.23523	-118.58814	New 600A service for (N) restaurant building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64611	10041-10000-18795	1925 S CENTURY PARK EAST 23rd floor	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24 and emergency lighting plan check for a portion of the 23rd floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64612	18041-20000-01533	1711 S GRIFFITH AVE	90021	14	121-5A211 235	5131001039	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Info Complete	01/31/2018 12:00:00 AM	ADDRESS	34.02701	-118.25263	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO EXISITNG GROWING FACILITY. 9664 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64613	14041-20000-11554	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLANCHECK FOR T24 ENERGY. T.I FOR 5TH FLOOR RESTROOM. HIGHRISE. 429 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64614	16041-20002-40256	432 S HARVARD BLVD	90020	10	135B193   546	5503010023	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			07/17/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	ADDRESS	34.06623	-118.30392	"7/17/17changes to an approved set of plans.  changes noted delta 1.  changes reflect field conditions.  this is plan chek only.""0$ permit fees due to senate bill 1222 ""Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 31.7kW (6kW*4+7.7kW) ungrounded system. (116) 340W pv modules."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64615	16041-20000-43352	7551 N TOPANGA CANYON BLVD	91303	3	186B101   208	2023001026	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	01/23/2017 12:00:00 AM	ADDRESS	34.20797	-118.60616	Addition of (6) LED downlights in commercial TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64616	13041-10000-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	COMPLETE RENOVATION OF CLASSROOM BUILDING CONSISTING OF BASEMENT AND TWO STORIES ABOVE. INCLUDES NEW LIGHTING, RECEPTACLES, HVAC, PANELS, AND A NEW SERVICE. EXISTING AND NEW WORK IS DIVIDED BY A DASHED LINE ON SINGLE LINE DIAGRAM. APPLICANT BROUGHT PRE-CUT CHECK, FEES TO BE RECALCULATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64617	18041-10001-11291	4201-4213 S VERMONT AVE	90037	9	114B197   797	5020027001	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Closed	07/20/2023 12:00:00 AM	ADDRESS	34.00713	-118.29174	CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES THE ADDITION OF THREE NEW SUBPANELS AND MODFYING THREE EXISTING PANELS (PANELS WERE SPLIT). NOTE, TOTAL AFFECTED AREA IS 10,953 SQFT, PREVIOUS APPROVED SET AREA WAS 10,870. ALL CHANGES ARE CLOUDED UNDER DELTA 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64618	19041-10000-17104	3921 W SUNSET BLVD	90029	13	145-5A203 330	5429013002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.09235	-118.27998	Plan check for Fire alarm system, Total fire alarm (30) fire alarm devices, (1) control panel and (1)  FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64619	18041-10000-05146	317 S BROADWAY # F4	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	34.05069	-118.24861	TI in existing take-out restaurant - new panelboard, lighting, and kitchen equipmentPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64620	18041-10000-30336	5500 W JEFFERSON BLVD	90016	10	120B173  1730	5047015033	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Closed	08/14/2018 12:00:00 AM	ADDRESS	34.02557	-118.3665	Conduit Only Permit(Early Start) for PCIS#18041-10000-28536	N	N	Express Permit	06/10/2024 12:00:00 AM
64621	11041-10000-13005	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	33.9867	-118.44159	Existing commercial building.  Relocating the electrical room and all the electrical equipment within the electrical room to the new location on the second floor.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64622	19041-20000-35464	9451 N CORBIN AVE	91324	12	198B117    68	2761040016	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.24147	-118.56249	T24 PLAN CHECK FOR NEW LIGHTS ONLY IN EXISTING LOW RISE COMMERCIAL BUILDING. TOTAL SQUARE FOOTAGE = 29,060 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64623	18041-20000-29922	12218 N SARAZEN PL	91344	12	216B137    61	2609011011	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM			Reviewed by Supervisor	08/22/2018 12:00:00 AM	ADDRESS	34.29158	-118.49608	pv1install roof mounted pv system sized 10.4KW AC interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64624	15041-10001-27012	12700 W MILLENNIUM #47	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	33.97639	-118.41499	Expedite per customer request.(((PV1 1.5KW roof-mounted system with (6) (SPR-X20-250 Sunpower AC - modules interconnecting through a sub-panel. Application is for plan check only, permit fee is paid under 15041-90000-26265.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64625	12041-10000-30060	788 S CENTRAL AVE	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	34.03414	-118.24273	PLAN CHECK FOR TITLE 24 IN ALAMEDA PRODUCE MARKET. SUITES #121, #118, AND #115.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64626	12041-10000-19718	13041 W SKY VALLEY ROAD	90049	11	156B133    33	4490012004	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Issued	09/20/2012 12:00:00 AM	ADDRESS	34.12655	-118.5083	New 7.91kw photovoltaic system for an existing single family residence.  System uses transformerless inverters and is an ungrounded system.  Permit includes the upgraded 200A main panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64627	11041-10000-26410	12614 N HENZIE PL	91344	12	219B133   126	2608008012	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.29992	-118.51097	New 10.34KW roof mountedphotovoltaic system for a single family dwelling with 4 strings.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64628	14041-20000-23641	6637 N BELLAIRE AVE	91606	2	180B161   420	2325012017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.19143	-118.40919	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size 3.8kW.(1) Fronius IG Plus Advanced 3.8-1UNI transformed inverter(18) Trina Solar TSM-240 PA05.08 pv modulesFIRE DECLARATION SIGNED PER REQUIREMENT NO.96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64629	16041-10000-25378	5550 W WILSHIRE BLVD 1-163	90036	4	132B181  1299	5089005***	[Q]C2-1-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.06206	-118.34979	PC FOR T24 ENERGY ONLY. NEW LIGHITNG IN RETAIL TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64630	17041-10000-42247	5166 N LANKERSHIM BLVD	91601	2	171B173   634	2353005014	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.16457	-118.37421	ALTERATIONS IN EXISTING RESTAURANT; PERMIT WAS OBTAINED ON  17041-20000-39050NEW LUMINAIRES AND CIRCUITSPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64631	19041-20000-43530	23219 W COLLINS ST	91367	3	174B093   214	2041008016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.17384	-118.63269	PV1.  Install 18.15 kW DC roof mounted grid tied PV system.  (55) modules with 5 kW and 10 kW rated inverters.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64632	15041-20000-11279	5008 N TILDEN AVE	91423	4	171A151   222	2248008040	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/15/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.16155	-118.44735	Plan check for a PV2 roof-mounted PV system. System size is 12 kWac and consists of (48) modules, (2) inverters, and (1) 125-amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64633	16041-10001-43145	5334 N ALHAMA DR	91364	3	171B105   311	2167024022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM			PC Approved	02/17/2017 12:00:00 AM	ADDRESS	34.1663	-118.59282	02/17/2017 Changes to an approved set of plan. Changes include remove GFCI to regular receptacle in walkin cooler. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64634	17041-10000-09308	2500 N SAN FERNANDO ROAD	90065	1	150B213   559	5457002003	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	PIN	34.10659029	-118.24057559	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 16400 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64635	13041-20000-28181	18426 W NORDHOFF ST	91325	12	195B125     6	2769001019	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.23523	-118.53468	New loads and lighting to an existing restaurant.  Occupancy load is 79.  Full plan check requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64636	13041-10000-25836	2171 S GUTHRIE DR	90034	5	126B165   340	4309016014	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.04318	-118.39319	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN IN A 2-STORY HOUSE. SYSTEM SIZE IS 6 KW DC, ON STANDARD PLAN.(24) MODULES: TRINA TSM-250PC05.18(1) INVERTER: FRONIUS IG 5100	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64637	12041-10000-21774	801 E COMMERCIAL ST	90012	14	130-5A217 174	5173019006	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	08/05/2013 12:00:00 AM	ADDRESS	34.05272	-118.231	RENOVATIONS IN THE OFFICES OF A STORAGE BUILDING-1ST FLOORPLAN CHK IS FOR TITLE 24 FOR INTERIOR LIGHTING SYSTEMONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64638	13041-10000-02859	230-330 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/06/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.04661	-118.2324	NEW FIRE ALARM SYSTEM FOR EXISTING APARTMENT COMPLEX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64639	19041-10000-38659	7939 N TALL PINE CT	91352	2	189B177   964	2409007031	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.21492	-118.36545	Plan check for a PV1 3.8KW AC / 4.3KW DC roof mounted system. Scope includes (1) inverter, (15) modules, and optimizers interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64640	18041-10001-20327	7843 N LANKERSHIM BLVD Suite #102	91605	6	189B169   517	2310025034	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	DELTA 2 changes to an approved set  for a first time occupancy of a new office space in Suite #102 on the first floor. Relocating panels RTL1, RPB and INVT to a different set  ( Clinic 17041-10000-36040) with changes to T-24. BUILDING PERMIT # 16016-10000-30872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64641	10041-10000-04208	19701 S HAMILTON AVE #250	90502	15	057B197    82	7351033015	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	33.85221	-118.28625	PLAN CHECK POWER AND ENERGY FOR T.I. REMODEL OF UPS FACILITY. NEW LOAD EXCEEDS 400AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64642	15041-20001-17244	14861 W BESSEMER ST #4	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.18089	-118.45728	07-27-2015 Plan check for lost original set of plans, Title 24 only.[[[Plan check for retail T.I. Title 24 only. Total area: 2,042 sqft]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64643	17041-10000-15330	5210 W OLYMPIC BLVD 1-4	90036	10	132B181   703	5084011018	R3-1	Central	Wilshire	Olympic Park		2162.00	Electrical	Electrical	Apartment			05/09/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.05691	-118.34296	Installation of fire alarm system in new 4 story 8 unit apartment building.  Total system size = 51 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64644	15041-10000-07526	811 W 7TH ST	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Expired	05/23/2017 12:00:00 AM	ADDRESS	34.04908	-118.25911	Replacement of electrical distribution equipment in (E) commercial highrise building.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64645	19041-20000-32297	8418 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64646	18041-20001-01275	350 S GRAND AVE Floors 8-12	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Info Complete	05/08/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	05-08-2018 Changes to an permitted set of plan. Changes include additional normal circuits supply to smoke damper and fire shutter. All changes had been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64647	13041-10000-34165	1550 N WILCOX AVE	90028	13	148-5A187 338	5546013002	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Public Safety Only			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.09947	-118.33087	new fire warning system for 4 stories apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64648	12041-10000-27526	315 W 9TH ST 11thfloor	90014	14	127-5A209 141	5144018049	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	PIN	34.04341508	-118.25728547	PC FOR ENERGY. TI TO EXISTING COMMERCIAL OFFICE HIRISE. 11th floor. PER APPLICANT AN EXPRESS PERMIT FOR THE WORK HAS BEEN PULLED. PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64649	18041-10000-31526	9540 N VAN NUYS BLVD	91402	6	201B149   735	2644025901	P-1VL, RD2-1, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM			PC Approved	08/20/2018 12:00:00 AM	ADDRESS	34.24411	-118.45004	T-24, PC FOR ENERGY ONLY,  SCOPE OF WORK INCLUDES. EXPAND CITY PARK; SCOPE OF WORK INCLUDES NEW POLE LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 11,436.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64650	18041-20000-45496	2843 W SAN FERNANDO ROAD	90065	1	153A213  1265	5457005013	R1-1-CDO, [Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.11168	-118.24341	Plan check for new Fire alarm system for Rabbit Academy faculty residence, Total fire alarm device: 113 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64651	16041-20000-38389	11319 N LOUISE AVE	91344	12	210B133    46	2711005008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.27616	-118.51121	"""$0 permit fees due to senate bill 1222 ""Plan check for a PV1 roof-mounted PV system. System size is 12.5 kWac and consists of (50) modules, (50) micro-inverters, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64652	18041-10000-10056	1651 N ALAMEDA ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			Permit Finaled	11/28/2022 12:00:00 AM	PIN	33.77885985	-118.23516542	PC for power for new conduit and wire pull in refinery supplying existing VFD motor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64653	14041-20000-04722	17346 W BURTON ST	91325	12	192B133   355	2201012003	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.22005	-118.51145	Roof mouted PV system with 5.75KW dc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64654	18041-10000-27691	4637 N LAUREL CANYON BLVD	91607	2	168B165   813	2356037007	R1-1-RIO, R4-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Apartment			07/24/2018 12:00:00 AM			PC Info Complete	12/14/2018 12:00:00 AM	ADDRESS	34.15506	-118.3967	PC FOR POWER AND ENERGY FOR A  PROPOSED 3 STORY IRR 14 UNIT APT OVER GARAGE PARKING.NEW SERVICE RATED AT 1000A 120/240V 3PHTOTAL AFFECTED AREA 16641 SQ.FT. (INDOOR AND OUTDOOR)SINGLE FAMILY AT THE FRONT OF THE LOT IS NOT PART OF SCOPE B#17010-20000-01152	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64655	11041-10000-24488	1056 S FREDERICK ST BLDG 2-2	90291	11	111B145   881	4243003032	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			11/28/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	33.99912	-118.46	Lincoln Place Apartment Building Project.  New 2-story apt. building with 8 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64656	19041-10000-48242	10122 N INDEPENDENCE AVE	91311	12	204B109   317	2747024074	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	02/29/2020 12:00:00 AM	ADDRESS	34.25432	-118.59062	(E-PLAN)NEW PV1 INSTALLATION FOR AN EXISTING SERVICE OF 100 AMPS. INSTALLATION INCLUDES 37 MODULES (YLM 60 CELL), 1 COMBINER BOX, AND 37 MICROINVERTERS (ENPHASE IQ7)SYSTEM SIZE: 11.47 KW DC; 8.695 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64657	17041-10000-39711	7337 N BALBOA BLVD UNIT 1	91406	6	186B133  1164	2227001***	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Apartment			11/02/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Issued	11/07/2017 12:00:00 AM	ADDRESS	34.20392	-118.50139	Install new rooftop solar system, 3.8 kW AC, (14) modules with power optimizers, and (1) central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64658	17041-30001-45533	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Closed	03/07/2019 12:00:00 AM	ADDRESS	33.94502	-118.40714	03-22-2018 Changes to an permitted set of plans. Changes include re-design lighting 3,500 sq ft, changed 18kW to 24 kW water heater. Changes has been clouded. changes apply to DCN-002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64659	11041-10000-25566	10320 W OLYMPIC BLVD Lobby-1st Floor	90064	5	129B161   103	4315018057	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM			Corrections Issued	12/01/2011 12:00:00 AM	ADDRESS	34.0522	-118.41724	New lighting and receptacles on two levels of an existing hotel, including the lobby.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64660	13041-10001-13095	624 S LA BREA AVE	90036	4	135B181   685	5507023023	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.06413	-118.34382	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT EXISTING BAKERY TO BAKERY/RESTAURANT. SCOPE OF WORK > 400A. ((((((((((((((((   changes made to previously approved set some lighting changed.   9-26-13  ))))))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64661	11041-10000-20193	6330 W SAN VICENTE BLVD 270	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	10/04/2011 12:00:00 AM	ADDRESS	34.06116	-118.36804	T-24 and emergency lighting in remodeled tenant space.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64662	12041-10000-29114	4204 N BARRYKNOLL DR	90065	14	154-5A219 236	5472009054	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2012 12:00:00 AM	12/07/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.11772	-118.22209	SINGLE STORY, PV1, ROOF MOUNTED SOLAR INSTALLATION USING M215 MICROINVERTERS AND STANDARD PLAN. 17 MICROINVERTERS, 17 PANELS AND A SINGLE BRANCH CIRCUIT. SYSTEM (DC) SIZE IS 4.165 KW AND (AC) SIZE IS 3.672 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64663	12041-10000-27063	8500 W BURTON WAY	90048	5	138B173  1332	4334016087	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Approved	01/30/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	TI TO RESTAURANT PART OF THE crusoe project approved per mehdi . not a high rise . 1799 SFDELTA 4 CHANGES TO THE APPROVED PLANS.     CONDITION WAIVED PER BEHZAD BY MEHDI 10/22/2012 (((((((((((((( cHANGES MADE TO PREVIOUSLY APPROVED SET, ADDITION OF 15HP  FIRE PUMP AND 3/4 HP JUCKY PUMP, CONVERSION OF TWO UNITS TO ONE PENT HOUSE, RELOCATING PANEL, LOAD CALS )))))))))))))))))(((((((((((( Revision to previously approved set , change of out door and indoor lits and title 24, new added ckts, relocation and reckting..  8-9-12  ))))))))))))))))))))))))New 88 unit apartment building, 8-story building, with 5-story type I-B (R2 occupancy) 88-unit apartment, over 3-story type I-B (S2/M occupancy), with 1-level basement parking garage.  Fees were adjusted to accomodate the applicants preprinted check.  The plan checker will review the plans and correct the plan check fees and any additional fee will be required at the time of  pickup of the first correction list.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64664	11041-10000-01617	4590 E HUNTINGTON DR NORTH	90032	14	142-5A229  96	5305035027	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.08584	-118.18834	New carwash in an existing gas station. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64665	18041-20001-17823	4145 N CAMELLIA AVE	91604	2	162B169    93	2368022025	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM			PC Approved	05/31/2018 12:00:00 AM	ADDRESS	34.14376	-118.38237	Plan check per inspector request, plan check for PV roof mounted, 5kW System with 22 modules and 1 inverter(5.0kw) Plan check only. Permit shall refer to original application 18041-90000-17823	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64666	18041-20000-29734	20800 W SPRUCE CIR (#74)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.29492	-118.58676	pv1install roof mounted pv system sized 3.8 KW aC interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64667	15041-20000-06664	13224 MIRA MAR DR	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	PIN	34.31120672	-118.40409465	PV1 SFD. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. TOTAL OF 24 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64668	16041-10000-28145	629 W 85TH ST	90044	8	097-5A201 156	6032018051	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	10/08/2016 12:00:00 AM	ADDRESS	33.96122	-118.28493	PV1. NEW  ROOFTOP SOLAR SYSTEM ON EXISTING TRIPLEX BUILDING. TOTAL SYSTEM SIZE IS 3.0KW.(10)MODULES-KYOCERA#KU2655ZPA(1)INVERTER-PVI-3.0-OUTD-S-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64669	18041-30000-16463	6731 N FALLBROOK AVE	91307	12	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.19189	-118.62364	Energy plan check for a new bar area inside movie theater. Scope includes new light and equipment, total area is 149-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64670	13041-20000-28020	333 S HOPE ST 34TH FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC FOR T24 ENERGY ONLY. TOTAL AREA 5190 SQ FT.OFFICES. NEW LIGHTING. WORK DONE IN 34TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64671	17041-20001-28522	20016 W BLYTHE ST	91306	3	189B113  1442	2106003135	(T)(Q)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2017 12:00:00 AM			PC Approved	08/21/2017 12:00:00 AM	ADDRESS	34.21466	-118.56922	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (20) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64672	16041-10001-12506	1175 E 21ST ST	90011	9	120A211   109	5131009036	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.02369	-118.25356	Changes to approved set, noted under Delta-3, consists of changing the module rooftop layout. All other remains the same. Permit shall be under the master E#<<PV1 rooftop solar installation on Duplex SFD, 2.15 kW AC.     (10) MODULES-HYUNDAI HiS-M250MG      (10) MICROINVERTERS-ENPHASE M215-60-2LL-S2X-IG>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64673	13041-10001-25283	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGES TO APPROVED SET OF PLANS. DELTA 3 CHANGES ONLY.PLAN CHECK FOR TITLE 24 ONLY. CHANGE OF USE FROM TAKE OUT RESTAURANT TO RETAIL SPACE 1,986 SF. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. TRANSFORMER IS EXISTING TO REMAIN LOCATED IN CEILING SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64674	19041-10001-30703	5601 W 78TH ST	90045	11	099B173   377	4104021001	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	ADDRESS	33.96731	-118.37918	EXPEDITED PER CUSTOMER REQUEST.PV1. INSTALL (38) ENPHASE IQ7PLUS MICROINVERTER WITH SYSTEM SIZE OF 12.73 KWDC / 11.54 KWAC ON EXISTING 200AMP SERVICE .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64675	14041-20001-28718	11608 W KITTRIDGE ST	91606	2	180B169   625	2335005004	RD3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			PC Approved	10/30/2014 12:00:00 AM	ADDRESS	34.19019	-118.38478	Fee for expedite only.*****New roof mounted PV system with system size 4.33KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64676	17041-20000-08103	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.04804	-118.46227	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 1558.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64677	15041-10002-07391	8431 W MELROSE PL	90069	5	141B173   416	5528001030	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.08376	-118.37442	Plan check for restamp of lost plans.  This set has updated home runs and increased panel busbar rating from 15041-10001-07391.TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1387	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64678	13041-20000-10333	16133 W VENTURA BLVD 1180	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM			Corrections Issued	09/26/2013 12:00:00 AM	ADDRESS	34.15675	-118.4847	Change to lighting only on existing circuits.  No other work.  Plan check only for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64679	14041-20005-15782	330 N WESTLAKE AVE	90026	13	136-5A207  71	5157025043	(T)(Q)RAS4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	08/21/2020 12:00:00 AM	ADDRESS	34.06951	-118.26652	6/4/2019changes to an approved set of plans.  changes to add new equipment and associated loads.  plan check for power only.  All changes noted delta 3.((((PLANCHECK FOR POWER AND ENERG. 200 UNIT APARTMENT. MIXED USE. 2 SERVICES OVER 3000 AMPS EACH. FEES CALCULATED PER ENGINEER. T24 FEES NOT CHARGED PROPERLY.))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64680	15041-10000-02013	21200 S BRIGHTON AVE	90501	15	051B193   340	7349021007	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM			Reviewed by Supervisor	02/03/2015 12:00:00 AM	ADDRESS	33.8363	-118.30043	PV1, INSTALL 3.57 ROOFMOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.14 MODULES AND 14 MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64681	10041-20000-08943	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			05/13/2010 12:00:00 AM			PC Approved	05/13/2010 12:00:00 AM	ADDRESS	34.24317	-118.50383	energy plan check conference room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64682	18041-10000-06406	1323 S ORANGE GROVE AVE 1-61	90019	10	129B177   318	5086004004	R3-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			02/21/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	01/05/2021 12:00:00 AM	ADDRESS	34.05256	-118.36538	Plan check for power and energy for 5-Story 61-Unit Condominium. Scope includes a new 4000A 120/208 V 3 Phase 4 Wire service, new panels, and new lights. Total area: 68,110 sq ft. B#16010-10000-05142	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64683	14041-20000-34482	16700 W FLANDERS ST	91344	12	213B137   522	2610013011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Expired	01/05/2017 12:00:00 AM	ADDRESS	34.27997	-118.49579	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(25) CANADIAN SOLAR CS6P-250P MODULES(1) SOLAR EDGE SE 5000 INVERTER(25) POWER OPTIMIZERS P-300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64684	14041-10000-04062	4527 W BRAZIL ST	90039	13	165B205    85	5593010017	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.14692	-118.27344	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTORE BUILDING. 19837 SQFT INDOORS + 2408 OUTDOORS. EMERGENCY LIGHTING. Changes on plan: include motion sensor for outdoor lighting (ckt B-11).BUILDING P# 14016-10000-02684	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64685	16041-10000-31677	3210-3214 W SLAUSON AVE	90043	8	108B185   910	4005005028	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Issued	10/27/2016 12:00:00 AM	ADDRESS	33.98884	-118.32856	T-24, PC FOR ENERGY ONLY. COMBINE TWO RETAIL SPACES INTO ONE RETAIL SPACE (T-MOBILE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1393 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64686	19041-10000-28707	550 S FLOWER ST 1st, 2nd,-& Roof	90071	14	130-5A209 186	5151024004	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	05/07/2020 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	34.05028	-118.25708	TI FOR AN EXISTING HOTEL PC FOR T24 ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES, AND EQUIPMENT IN THE 1ST FLOOR AND SECOND FLOOR LOBBY. TOTAL AFFECTED AREA IS 2672 SQFT. B#: 19016-10000-21333	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64687	17041-20000-25474	6033 W CENTURY BLVD Ste 970	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	33.94572	-118.38954	Office remodel in commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64688	14041-20000-16877	10351 W SANTA MONICA BLVD SUITE 402	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	PIN	34.0585564	-118.42324002	PC FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING.  EXISTING COMMERCIAL HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64689	12041-10000-18166	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Approved	08/03/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING T.I. FOR OFFICE #1100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64690	13041-20001-29716	15651 W RAYEN ST	91343	12	195B141   333	2672009034	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM			PC Approved	10/27/2013 12:00:00 AM	ADDRESS	34.23203	-118.47366	(((EXPEDITE FEES))))PV1 12.99KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 2) INV: PVI-5000-OUTD-US and PVI-6000-OUTD-US] [( 53) MOD: yingli {YL245-29b}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64691	18041-20001-26637	9617 N LEMONA AVE	91343	7	201B145   556	2650002022	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM			PC Approved	07/23/2018 12:00:00 AM	ADDRESS	34.24511	-118.45898	PV1.  Install 17.69 kW roof mounted grid tied PV system.  (58) modules with 11.4 and 5.0 kW rated string inverters. Portion of PV system on detached structure.  Derating of main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64692	19041-10000-34206	634 N ALMA REAL DR	90272	11	126B129   736	4411011009	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	01/24/2020 12:00:00 AM	ADDRESS	34.03906	-118.52375	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 7.6KWac/10.8KWdc. SCOPE OF WORK INCLUDES 32 MODULES (LG340N1C-V5) WITH OPTIMZERS (SE P370) LEADING TO A CENTRAL INVERTER (SE7600A-US), WITH A BATTERY (LG CHEM RESU 10H) AND A CRITICAL LOADS PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64693	18041-10000-30298	1670 W BEVERLY BLVD UNIT #2	90026	13	135A207   236	5153012023	C2-1	Central	Westlake	Westlake North		2083.01	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.06416	-118.26523	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE OF USE FROM OFFICE TO RESTAURANT. 920 SQFT INDOOR + 85 SQFT OUTDOOR. UNIT 2BUILDING PERMIT # 18016-10000-06616	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64694	17041-20000-21603	10106 W TOLUCA LAKE AVE	91602	4	165B181   355	2424031015	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Refund in Progress	10/24/2017 12:00:00 AM	ADDRESS	34.14844	-118.35008	plan check for power only.  addition of battery backup (powerwall 5kw).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64695	13041-10000-16373	26210 S ATHENA AVE	90710	15	033B193   489	7411018015	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	33.78478	-118.30485	Roof mounted P.V. system with 6.25 KW equiped with microinverters.  Due to the old fees, rooftop was not applicable.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64696	17041-30000-02345	6656 W HOLLYWOOD BLVD	90028	13	148-5A185 137	5547014010	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Issued	08/22/2017 12:00:00 AM	ADDRESS	34.10134	-118.33536	"Plan check for power and Title 24.  T.I. to existing theater and adjacent retail area.  Assembly occupancy.  Total area = 2,500 sq. ft. COMPLY WITH DEPARTMENT ORDER effective date 01/28/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"" Building permit #17016-10000-00858"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64697	10041-10002-19732	520 S VIRGIL AVE # 306	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM			PC Approved	12/02/2010 12:00:00 AM	ADDRESS	34.06457	-118.28687	Supplemental application to approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64698	19041-20000-19690	7900 N BALBOA BLVD	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	10/13/2021 12:00:00 AM		Permit Finaled	04/26/2024 12:00:00 AM	ADDRESS	34.21347	-118.50092	PV3.  Install 2,956.1 kW roof mounted PV system across multiple aircraft hangar buildings.  (6569) modules with (39) 60 kW and (5) 36 kW rated inverters.  Feed-in tariff project.$0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64699	13041-10000-09313	19500 W PLUMMER ST SUITE G3	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW TENANT SPACE. EXISTING SERVICE. 800A SWITCHBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64700	16041-20000-12343	10100 W SANTA MONICA BLVD 24th Floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	10/13/2016 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for energy only. TI to restrooms on 24th floor of existing high rise office building. New lighting (incl. emergency). 458sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64701	19041-20002-18284	4915 W LOS FELIZ BLVD	90027	4	150B197   103	5588009007	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	34.11049	-118.2963	07/08/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to match field installation.*****Original Work Description*****PV1 Plan check for new PV roof mounted system on existing sfd, PV system size: 15.2kW AC, 15.9KW DC with 49 Q cell PV Modules and 2 inverters(7.6kW) connected to existing 400A Service panel and a new 100A solar subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64702	19041-20001-12176	8250 N WOODMAN AVE	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			PC Approved	10/18/2019 12:00:00 AM	ADDRESS	34.22107	-118.43251	10-18-2019 Chanages to an approved set of plan, changes revise new lighting layout. All changes has been clouded as delta A. Plan check only, permit cover under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64703	16041-10000-40667	5142 N TUJUNGA AVE	91601	2	171B173   726	2353002030	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.16425	-118.37883	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 10250 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64704	14041-20001-28973	811 S CARONDELET ST	90057	1	132A201   143	5141025027	(T)(Q)C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Apartment			10/20/2014 12:00:00 AM			PC Approved	01/30/2015 12:00:00 AM	ADDRESS	34.0564	-118.28261	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. 10KW AC.(25) PV MODULES(1) POWER ONE 10.0	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64705	17041-20000-15275	1555 N AMALFI DR	90272	11	132B133   106	4425021004	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.05932	-118.50418	new sfd 600 amp service.  plan check for power only.building permit # 16010-30000-04257	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64706	16041-10000-01590	2049 S CENTURY PARK EAST S340	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24, TENANT IMPROVEMENT TO (E) OFFICE.  CONSTRUCT NONBEARING PARTITIONS, CEILING, MILLWORK AND FINISHES. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT.  1,605 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64707	18041-10000-05328	10250 W SANTA MONICA BLVD #2580	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant ""HealthySpot"" suite 2850 in Westfield Century City. Install (2) new panles, and (1) 45 kVA xfrm. New lights and powers. Total area: 1382 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64708	17041-20001-03163	20440 W KESWICK ST	91306	3	186B109   101	2114002005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM			PC Approved	02/04/2017 12:00:00 AM	ADDRESS	34.20957	-118.57883	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating main breaker to 175A. 10.4kW ungrounded system (5.2*2). (37) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64709	19041-20000-48868	24365 W STONE BEND LANE	91304	12	192B089   174	2017038006	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.2205	-118.65625	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 2.88 KW DC/5.2 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH A 5.2 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64710	17041-10000-12843	10250 W SANTA MONICA BLVD # 1895	90067	5	132B161   512	4319003066		West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""Warby Parker"" Ste. 1895.  Total area: 1,107 sq.ft*DB ELA41"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64711	19041-20001-18517	4152 N FALLING LEAF DR	91316	5	165B125   353	2184032032	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	06/07/2019 12:00:00 AM	ADDRESS	34.14618	-118.52522	PV1.  Install 21.6 kW roof mounted grid tied PV system.  (60) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64712	16041-10000-10748	7671-7673 W BEVERLY BLVD	90036	5	138B177   424	5527041004	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.07629	-118.35712	TI, PC for Energy only, total area 1,555 sq.ft.   Service upgrade under separate Permit# 15041-10000-43499. <<PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO  TAKE OUT DELI. 800A SERVICE UPGRADE under 15041-10000-43499>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64713	18041-10000-48280	1853 E 1ST ST	90033	14	129A221   205	5174014047	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.04696	-118.21799	plan check for fire alarms system consisting of 1 fire alarm panel and 11 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64714	13041-10001-23187	1028 S SEASIDE AVE Berth 259	90731	15	015B205    18	7440032904		Harbor	PORT OF LOS ANGELES			2961.00	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	33.73466	-118.26899	2/11/2015 Plan is being resubmitted as the original approved set of plans was lost. Permit was issued on the original set of plans. Plan check for the installation of a new 225-amp rated panel, and associated loads. Area is a Class 1 hazardous area.(((Plan check for new service and power for above ground (3) 12,000 gallon tanks (diesel) for refueling boats. Berth 259)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64715	19041-20000-21082	24548 W EILAT ST	91367	3	177B085   607	2032022001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.17734	-118.65966	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.4KW DC/11.244KW AC CEC/11.4KW AC. SCOPE OF WORK INCLUDES (40) SILFAB PV MODULES WITH P320 POWER OPTIMIZERS, AND A SE11400H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64716	16041-10000-40710	6500 W WILSHIRE BLVD #2250	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.06371	-118.3703	PC for energy only for an existing highrise medical center building on suite 2250. Scope of work includes new lights for an existing office space(non-medical). Total sqft = 4218. B#16041-10000-40710	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64717	14041-20000-09729	515 S FIGUEROA ST SUITE 1425	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI for commercial office space in existing commercial highrise building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64718	17041-10000-32512	10250 W SANTA MONICA BLVD FC 7	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR T24 ONLY T.I. FOR EXISTING TAKE-OUT RESTAURANT (UNIT# FC-, Z-PASTA BAR) AT EXISTING SHOPPING MALL FOOD COURT AREA	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64719	16041-10000-00290	1070 S BEDFORD ST 1-19	90035	5	132B169   448	4332021027	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			01/11/2016 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.0573	-118.38026	FULL PC FOR A NEW 19-UNIT APARTMENT BUILDING. TOTAL AFFECTED AREA IS 22661 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64720	17041-10001-12681	600 S COMMONWEALTH AVE	90005	10	135A201   145	5077006011	C4-2	Central	Wilshire	MacArthur Park, Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.06348	-118.28545	"PC for power for changes to approved set. Chaning conduit from 3""to 2"" and downsizing egc to #4 from generator to transfer switch. All changes clouded under delta."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64721	17041-10000-21253	108 N FREMONT AVE	90012	14	133-5A211 226	5161002906	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.05856	-118.25265	T24 ONLY - REPLACEMENT OF EXISTING LIGHT FIXTURES WITH (23) LED FIXTURES.  TOTAL AFFECTED AREA =   35500SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64722	16041-20000-25530	515 S FIGUEROA ST Suite 1975	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for energy only. TI to existing office suite #1975. New lighting (incl. emergency) and receptacles. 3,577sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64723	17041-10000-16654	20101 S VERMONT AVE	90502	15	057B197    73	7351034061	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.84832	-118.29066	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 42000 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64724	14041-10000-17433	5711 W CENTURY BLVD	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	33.94573	-118.38128	T24 ONLY. TI FOR LOWER LOBBY RETAIL SPACE. TOTAL AREA 2055 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64725	12041-10001-15263	400 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	SUPPLEMENTAL PC ONLY FOR 12041-10000-15263. CHANGES ARE CLOUDED. ADDING NEW 100AMP SUBPANEL AND 32 BRANCH CIRCUITS. CHANGING HOOD BRANDS. PC BEING DONE UNDER APPLICANTS REQUEST.TERMINAL 4B - GOURMET FOOD TRUCK AREA TO BE PERMITTED SEPERATELEY PER INSPECTORS REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64726	12041-20000-02443	1515 W 190TH ST #555	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	33.85852	-118.30531	T.I. to existing space.  Relocate some light fixtures.  Plan check for energy only.Note: permit under 12041-90000-00395	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64727	10041-10000-17110	5540 W PICO BLVD	90019	10	129B177   820	5069019028	C4-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.04939	-118.35931	New fire alarm system for preschool.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64728	19041-20000-41388	11825 W TERRA VISTA WAY #136	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64729	14041-20000-26064	14501 W MULHOLLAND DR	90077	4	159B149   327	2275028007	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.13166	-118.4487	600A SFD SERVICE UPGRADE.    Panel schedules to be provided by applicant prior to assignment of plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64730	11041-10001-12606	616 N ALAMEDA ST	90744	15	030B213   219	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM			PC Info Complete	04/05/2012 12:00:00 AM	ADDRESS	33.77832	-118.24681	CHANGES TO APPRVED PLANS.  LOST PLANS. RECHECK FOR POWER.   New 1600Amp service & Distribution board for the port of LA.  EPC is for Power.   No New Load added.   <<<EPC will be required when the FUTURE 500 Amp Load is added.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64731	13041-10000-17643	12883 W RUNWAY ROAD unit 1-3	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/03/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	33.97519	-118.42049	PLAN CHECK POWER AND ENERGY FOR NEW 3-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #6  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64732	18041-20000-22956	12131 N LOUISE AVE	91344	12	216B129    65	2606027061	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Issued	06/26/2018 12:00:00 AM	ADDRESS	34.2918	-118.5134	Plan check for PV roof mounted system, system size: 3.77kWac with 13 modules and 13 microinverters connected to 400A service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64733	12041-20000-10020	12300 W WILSHIRE BLVD Ground-Floor	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	07/24/2012 12:00:00 AM	ADDRESS	34.04245	-118.46922	T24 lighting plan check for ground floor mens and womens restarooms.  Replace existing luminaires with new.  Reuse existing branch circuits and lighting controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64734	11041-20000-11259	2049 S CENTURY PARK EAST 2ND FL	90067	5	132B161   698	4319016030		West Los Angeles				2679.01	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	06/01/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR OFFICE TI ON THE 2ND FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64735	19041-10001-18567	865 S FIGUEROA ST 31ST FLOOR	90017	14	129A207   241	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM			PC Approved	07/15/2019 12:00:00 AM	ADDRESS	34.04653	-118.26275	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY. CHANGES APPLY TO RENOVATION OF EXISTING OFFICE NEW RECEPTACLES AND LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64736	19041-10000-13216	10915 W OTSEGO ST	91601	2	171B173   894	2419002018	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.16301	-118.36854	PC for new 800A , 240/120V, 3W service feeding (10) 200A panels, core and shell only. Per BH (responsible engineer will be provided)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64737	14041-20001-13338	6919 N CASTLE PEAK DR	91307	12	183B085   115	2031010025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.19794	-118.66002	EXPEDITE PER CUSTOMER REQUEST.PV1  INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.94KW INTERCONNECTED WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS SOLAREDGE SE 3800A(39) TRINA SOLAR MODULES TSM-PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64738	11041-10002-24713	818 W 7TH ST Ste 510	90017	14	129A209    45	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Info Complete	01/12/2012 12:00:00 AM	ADDRESS	34.04895	-118.25943	Changes from previously approved plans.  The changes ar to T24 fixtures on first approval were not found, now been replaced total wattage within limit.  Plan check for energy only.  Permit is existing*****T.I. to an existing office building on the 5th floor.  PLAN CHECK ONLY for Energy, with Emergency lighting.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64739	15041-20000-00846	630 S ANDERSON ST	90023	14	126A219   129	5171006011	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	01/26/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.03793	-118.22343	Plan check for energy only. CHANGE OF USE FROM WAREHOUSE/INDSTRIAL USE TO DOG DAY CARE, OFFICE, ACCESSORY USE FOR DOG DAY CARE ,NEW STOREFRONT ,AND TENANT IMPROVEMENT. New receptacles and lighting (incl. emergency). 4,458sqft indoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64740	12041-10000-30625	601 S FIGUEROA ST 6TH FLOOR	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. TENANT IMPROVEMENT FOR ALL OF THE 6TH FLOOR. HIGH RISE (GENERATOR). USING AREA CATEGORY (17,104 SQ FT < 30,000).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64741	13041-10000-24466	14840 W BLACKHAWK ST	91345	7	204B149   174	2648009015	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.25804	-118.45595	PV1. ROOF MOUNTED SOLAR ARRAY. SYSTEM SIZE: 10KW. 40 MODULES. CENTRAL INVERTER. 1 STORY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64742	17041-30000-34911	1250 N CAPRI DR	90272	11	129B133    73	4407014007	A1-1XL, R1H1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2628.02	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.05121	-118.50122	Plan check for Title 24 only in existing space T.I. Riviera Country Club Vista Riviera Club Wing. Total area: 4891  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64743	17041-10002-08055	7270 1/2 W MELROSE AVE	90046	5	141B181   622	5525013004	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.08338	-118.34821	PC FOR T24 ENERGY ONLY. CHANGE OF USE TO STUDIO. PROVIDING GENERAL LIGHTING NORMALLY OFF AND STAGE LIGHTING SEPARATE FROM GENERAL LIGHTING. PERMIT ALREADY ISSUED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64744	16041-10000-41203	739 S DECATUR ST	90021	14	124-5A215  99	5166032049	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.03325	-118.2353	REPLACE HID FIXTURES WITH NEW LED FIXTURES T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64745	12041-10000-30179	5700 W WILSHIRE BLVD 4th Floor	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.06218	-118.35303	TI in an existing office Bldg. 4th floor of a highrise BLDG. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64746	17041-20001-05835	4664 N DEL MORENO DR	91364	3	168B113   418	2174019014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.15491	-118.57526	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64747	13041-20000-11510	1845 S WESTWOOD BLVD	90025	5	129B153   648	4323001093	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			PC Approved	05/03/2013 12:00:00 AM	ADDRESS	34.04887	-118.43624	T24 FOR EXISTING STRIP SHOPPING CENTER. NEW LOAD DOES NOT EXCEED 400AMPS. 4625 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64748	14041-20001-05217	5808 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97391	-118.41962	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLINT. TOTAL SYSTEM SIZE 3KW AC USING 9 MODULE.S TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64749	15041-10000-09643	19600 W PLUMMER ST # 700	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/01/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.2426	-118.5602	T.I FOR NEW RESTAURANT, PC FOR ENERGY AND POWER.  PROOSED OCCUPANT LOAD EXCEEDS 100 OCCUPANTS PER APPLICANTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64750	19041-20000-00930	12403 W VENTURA CT Ste A	91604	2	162B165   139	2367018046	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.14337	-118.40324	Medical office TI.  Plan check for power and energy.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64751	16041-10000-20101	9615 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.2446	-118.59846	PC for T-24 only, remove HID fixtures and replace with LED fixtures. Total area: 5,607 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64752	17041-20000-23361	15643 W LA MESA ST	91342	7	222B141    50	2604005013	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.30843	-118.47357	PV1.  Install 9.0 kW roof mounted grid tied PV system.  (2) inverters, 3.8kW/5.2kW.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64753	17041-10000-46398	242 W MT WASHINGTON DR	90065	1	145-5A223  98	5451014011	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.09408	-118.2126	PC FOR ROOF MOUNTED PV ON SLD. SYSTEM SIZE 9.72KWACSCOPE INCLUDES 27 AC MODULES WITH PV LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64754	13041-20000-32967	3550 N MULTIVIEW DR	90068	4	159B177   471	2425010019	RE15-1-H, RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.1315	-118.3605	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 4.32KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64755	09041-10001-08880	971-975 N YALE ST	90012	1	136-5A215 182	5414002001	C2-2D-O	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	34.06681	-118.23916	Change the priviously approved plan. Change from Level V to IV of Methane. All changes are clouded. ((((((((NEW METHANE DETECTION SYSTEM FOR CHURCH.  PLAN CHECK  FOR POWER.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64756	14041-20003-18621	19626 W NORDHOFF ST	91324	12	198B117   223	2783028004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM			PC Approved	08/05/2016 12:00:00 AM	ADDRESS	34.23527	-118.56116	08-05-16. Changes to an approved set of plans. Changes include run new feed to connect to existing feeder and update EGC and clouded area. ********************Previous Work Description***********************3.21.2015 - Plan check for modifications to approved set. Update single line diagram to reflect that service distribution equipment is all new. See sheet E-3.1. ---Remodel of (E) commercial restaurant space (single-story building).  Plan check for power and energy.  Proposed occupant load of 308.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64757	15041-10000-31889	1075 W CHILDS WAY	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	05/09/2016 12:00:00 AM	ADDRESS	34.02304	-118.29105	NEW FIRE ALARM SYSTEM TO AN (E) BUILDING. 82 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL AND 1 GRAPHIC ANNUNCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64758	12041-20000-09480	16027 W VENTURA BLVD 350	91436	5	168B141   538	2261022106	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM			PC Approved	04/25/2012 12:00:00 AM	ADDRESS	34.15641	-118.48225	T-24 and emergency lighting plan check for a remodel for suite 350 in low rise commercial building.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64759	14041-10000-16587	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	TI in terminal 5 in LAX.  Plan check for power and lighting.  Total area = 425 sq. ft.Provide lighting, electrical distribution, 20 kVA UPS system, and power for 2 renovated spaces used as IT rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64760	17041-30000-08131	1947 S SAWTELLE BLVD	90025	11	126B153  1455	4261030052	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.04122	-118.44415	Plan check for power and energy. Project site is a new 4-story, mixed use building with 72 apartment units and 2 levels of  subterranean parking garage. Total lighting area = 79,498 sq. ft.Note: Building application has been generated under 14010-10000-04166	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64761	17041-10000-39765	1437 S ARMACOST AVE 1-18	90025	11	126B145   338	4263031016	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			11/02/2017 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.04288	-118.46135	PC FOR New 18 unit 3-story over garage basement apartment.SERVICE RATED AT 1000A 120/240VTOTAL AFFECTED AREA 13500SQ.FT INDOOR. TOTAL OF 2 TYPICAL UNITS. B#17010-10000-02522	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64762	19041-10000-39698	4501 W COLORADO BLVD BLDG 5A	90039	13	162B205    19	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	02/03/2021 12:00:00 AM	ADDRESS	34.14246	-118.2705	TWO PHARMAUCETICAL MANUFACTURING BUILDINGS COMBINE AS ONE BUILDINGSERVICES EXISITING NEW MANUFACTUINT EAQUIPMENT AND CHANGES TO THE LIGHTING SYSTEM. FIREEAPPROVAL FOR STORAGE OF LIQUIDS HAS BEEN OBTAINED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64763	12041-10003-04692	4400 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.09662	-118.28529	REVISION TO THE APPROVED PLAN. ALL THE CHANGES ARE SHOWN WITH DELTA 6 BULLETIN#3. PLAN CHECK FOR AN OFFICE BUILDING OF A CHILDEREN HOSPITAL.EPC FOR DELTA 9.(((((((((((((( TI OFFICE RENOVATION. 40,000 SQ FT. SINGLE STORY. T24 EMERGENCY LIGHTING, POWER INCLUDED. FIRE ALARM VARIANCE ISSUED. )))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64764	10041-20005-24663	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Info Complete	05/10/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	"05-10-2016 CHANGES TO APPROVED SET OF PLANS. CHANGES ON DELTA ""F"", ADDITIONAL OF CIRCUITS FOR MECHANICAL DAMPERS, SOKE FIRE DAMPERS, IRRIGANTION CONTROLLER, VFD  FOR CT-1, VALVE FLOAT CONTROL, AND REVISED LIGHTING FIXTURE IN CORRIDOR 117, AND UDATE CIRCUTIS ON PANEL, RLA, 1LBA, 1LLA, 3LLA, 5LLA, 2EQLA, AND REQLA. ****************PREVIOUS WORK DESCRIPTION**************************************[[[ 1/7/16 CHANGES TO APPROVED SET. DELTA 67 CHANGES ONLY. CHANGES TO SHORTCIRCUIT RATINGS OF PANELBOARDS. SHORTCIRCUIT STUDY HAS BEEN PROVIDED.]]]]]PLAN CHECK FOR LOST SET OF PLANS. RECHECK THIS ENTIRE SET AS NEW. PER BUILDING PC IN ACCORDANCE TO 2008 ENERGY CODE. PERMIT WILL BE ISSUED FOR DIFFERENCE IN INSPECTION ITEMS FROM ORIGINAL APPLICATION."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64765	19041-10000-36567	5528 N TAMPA AVE	91356	3	174B117   420	2163016013	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.17163	-118.55332	[EPLAN] PLAN CHECK FOR ROOF MOUTED PV1 SYSTEM CONSISTING OF 45 MICRO INVERTS(IQ7X-96-2-US) CONNECTED TO EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64766	18041-10000-38017	230 E ADAMS BLVD	90011	9	120A207   153	5128001038	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	03/26/2019 12:00:00 AM	ADDRESS	34.02375	-118.2666	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64767	15041-20000-15070	6600 N TOPANGA CANYON BLVD Unit 1059	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 985 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64768	19041-10000-38832	2365 E CENTURY BLVD 3E	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	07/08/2020 12:00:00 AM	ADDRESS	33.94668	-118.2305	"FIRST TIME TENANT FOR A NEW ""HABIT"" RESTAURANT IN SUITE #3E.  PLAN CHECK FOR POWER & ENERGY. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 2,833 SQ/FT.BULDING PERMIT: 19016-10000-30717"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64769	11041-20000-01594	15853 W MONTE ST #107	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM			PC Approved	01/26/2011 12:00:00 AM	ADDRESS	34.31022	-118.47637	revision delta 1 plan check only existing permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64770	14041-10000-04488	2476 W LOY LANE	90041	14	162A219    96	5683025035	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Expired	03/16/2016 12:00:00 AM	ADDRESS	34.13944	-118.2213	PV Installing 10 KW DC roof_mounted solar array on a single family home. Installing enphase 215 microinverte.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64771	15041-10001-21070	9784 W DRAKE LANE	90210	5	156B157   286	4385010013	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM			PC Approved	07/22/2015 12:00:00 AM	ADDRESS	34.1233	-118.42598	PV1 10KW rooof-mounted system with (40) Kyocera KD260 modules, and (1) Solaredge SE10000A-US inverter interconnecting through the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64772	16041-10000-18513	416-424 N NORTH MAIN ST	90012	14	132A215   103	5408008905	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM			PC Info Complete	07/05/2017 12:00:00 AM	ADDRESS	34.05582	-118.23978	PC FOR POWER AND ENERGY. TOTAL AREA 19000 SQ FT. ADDITION OF 14 NEW PANELS AND TRANSFORMERS.  B# 16014-10000-02441 BUILDING DESCRIPTION:REHAB OF 3 STRUCTURES, MASONIC HALL AND MERCED THEATRE, WITHIN EL PUEBLO HISTORIC PARK; REHAB OF STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS REQ TO ACCOMODATE TO A NEW 18000 SQ FT TELEVISION STUDIO; SEISMIC RETROFIT DESIGN FOR PICO HOUSE STRUCTURE (424 N MAIN) WHICH IS STRUCTURALLY TIED TO THESE STRUCTURES, HAS BEEN SUBMITTED TO BE PLAN CHECKED CONCURRENTLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64773	13041-10000-33292	3012 S BRIGHTON AVE	90018	8	120B193   456	5053032030	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.02683	-118.30131	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS UNGROUNDED SYSTEM. SYSTEM SIZE: 4.7kW. (20) TRINA TSM-235 MODULES(1) POWER ONE PVI-4.2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64774	14041-20001-35962	7888 N VAN NUYS BLVD 1-2	91402	6	189B149   639	2212028015	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	34.21514	-118.44612	Supplemental change to an approved set of plan. Adding lighting fixtures A/AE, A1/A1E. PC for T-24 only. Total area: 11,096sq. ft. Permit Under 14041-20000-35962. (((Plan check for power and energy. CHG OF USE FROM TRADE SCHOOL TO RETAIL (Pet's Mart) ALSO EQUIPMENT PLATFORMS @ ROOF. Existing service, pull section, and service disconnect, all other electrical work is new.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64775	11041-10000-12034	15725 W PARTHENIA ST	91343	12	195B141   558	2672011043	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	01/30/2013 12:00:00 AM	ADDRESS	34.22848	-118.47482	TI TO AN EXISTING SINGLE STORY OCCUAPTIONAL EDUCATION BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64776	17041-10000-44525	9636 N VARIEL AVE	91311	12	201B105   198	2746006020	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.24581	-118.59277	Remove HID fixtures and replace with new LED fixtures  T-24 only.TOTAL SQ.FT 15500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64777	16041-10000-12055	1315 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	33.78944	-118.24745	PV1 INSTALL 1.72 KW AC ROOF-MOUNTED SOLAR ARRAY FOR A UNIT WITHIN A 3 UNIT APARTMENT PER SINGLE LINE. (8) MODULES: HYUNDAI HIS-M250-MG(8) MICROINVERTERS: ENPHASE ENERGY M215-60-2LL-S22-IG	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64778	13041-10000-24749	20422 W CORALINE CIR	91311	12	207B109   446	2707018003	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.26306	-118.57883	PV1. INSTALL 9.8 KW DC ROOF MOUNTED SOLAR ARRAY OF 40 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS. DC UNGROUNDED WITH POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64779	17041-10000-19508	523 W 6TH ST 12TH FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	Plan check for T24 only, T.I. to remodel men's and women's restrooms on the 12th floor. B# 17016-10000-06819	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64780	17041-10000-41136	900 N ALAMEDA ST 2nd & 3rd-floor	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC for T24 only for third and second floor of four story building. Installing new lights and re-conecting receptacles to existing circuits.B#17016-10000-23810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64781	14041-10000-18211	1623 S 2ND AVE PV1	90019	10	126B189   373	5072033017	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.20	Electrical	Electrical	Apartment			07/07/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	34.04288	-118.31907	PLANCHECK ONLY FOR PV2 PER INSPECTORS REQUEST (APARTMENT, NOT A SFD) . PERMIT PREVIOUSLY PULLED UNDER 14041-10000-17405.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64782	12041-10001-19992	18705 W VENTURA BLVD	91356	3	174B121   514	2160002005	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Approved	09/14/2012 12:00:00 AM	ADDRESS	34.17095	-118.54095	Revision to approved plans. Revise T24 calculation and add light fixtures. T.I. to existing bank (Chase) in the office area.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64783	17041-10000-31587	2337 N HIGH OAK DR	90068	4	153B193   292	5587003021	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.11299	-118.31207	PC FOR PV SYSTEM RATED 11.4KW AC (10.05 KW DC) USING CENTRAL INVERTER  AND 30 MODULES. SYSTEM USES POWER OPTIMIZERS.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64784	14041-20001-34388	333 S GRAND AVE 40th flr	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64785	17041-10000-27698	2944 N BOTTLEBRUSH DR	90077	5	156B149    15	4379035***	RE15-1-H-RPD-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.12754	-118.44799	NEW ROOFTOP SOLAR SYSTEM ON SFD 10 KILOWATT AC SYSTEM (1 INVERTER, 38 MODULES WITH 38 OPTIMISERS)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64786	13041-10000-25827	5927 W CARLTON WAY	90028	13	148-5A191 215	5545005900	OS-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.10057	-118.31889	permit to be pulled at EPC counter. PC for energy only. NEW SITE LIGHTING FOR CARLTON WAY POCKET PARK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64787	13041-10000-16729	315 E CULVER BLVD	90293	11	096B149   309	4116009018	[Q]C4-1D	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	33.95995	-118.44745	Original scope of work: NEW 3-STORY OFFICE BLDG W/PARKING AT GROUND LEVEL.LOAD LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64788	15041-10002-00589	12655 W BLUFF CREEK DR	90094	11	102B161  1281	4211037037	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/15/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	33.97565	-118.41332	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 6 ON PLANS. CHANGE FEEDER FROM CONDUIT TO MC CABLE AS NOTED ON PLANS. PC ONLY. PERMIT ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64789	19041-10000-47744	3115 W ADAMS BLVD	90018	10	123B189   650	5059028010	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2189.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Closed	10/01/2021 12:00:00 AM	ADDRESS	34.03279	-118.31817	NEW FIRE ALARM CONSIST OF 1 FA PANEL, ANNUNCIATOR, COMMUNICATOR AND 41 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64790	14041-20000-17382	9830 N LAUREL CANYON BLVD	91331	7	201B157   285	2622017005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.24864	-118.42109	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.5KW INTERCONNECTED WITH MSP.(14) HYUNDAI M250MG MODULES(14) M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64791	19041-10000-12176	8250 N WOODMAN AVE	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	03/11/2021 12:00:00 AM	ADDRESS	34.22107	-118.43251	PLAN CHECK FOR MEDICAL OFFICE TENANT IMPROVEMENT. TOTAL EFFECTED AREA 3077 SQFT.BLD# 19016-10000-09606	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64792	19041-20000-00972	11556 W CUMPSTON ST	91601	2	174B169  1198	2350002033	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.16986	-118.38427	Plan check for Energy Storage System install in to existing PV system, Energy storage system size: 27kWh with 2 Tesla Energy storage (13.5kWh)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64793	12041-10000-14619	123 S FIGUEROA ST	90012	9	132A211     6	5151001026	C2-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	06/25/2013 12:00:00 AM	ADDRESS	34.05725	-118.25278	PLAN CHECK POWER AND ENERGY REMODEL/CONVERSION OF OFFICES TO 6 RESIDENTAIL APARTMENTS (BUILDING #3, LEVEL 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64794	16041-20000-35082	8372 N TOPANGA CANYON BLVD	91304	3	192B101   469	2779043035	(Q)C1.5-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Closed	07/06/2017 12:00:00 AM	ADDRESS	34.22187	-118.60576	Plan check for energy only. Redoing electrical for 5 tenant spaces on first floor of commercial building. 2nd floor existing to remain. New lighting (incl. emergency) - T24 - 6,916sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64795	18041-30000-14485	1900 S AVENUE OF THE STARS Suite 1800	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	08/11/2018 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for Title 24 only. Project site is a suite in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,956 sq. ft.Note: Building application has been generated under 18016-10000-08877	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64796	10041-20000-21021	7648 N CLYBOURN AVE	91352	2	186B177   576	2466029049	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.20933	-118.36317	Plan check for new installation for 600amp switchboard on existing 1600A service and re-feed existing equipment to new 600amp switchboard. All loads are existing to remain for scope of work.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64797	17041-20000-04010	10866 W WILSHIRE BLVD SUITE 360	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM			PC Approved	02/07/2017 12:00:00 AM	ADDRESS	34.05907	-118.442	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. 1260 SQFT. HIGHRISE. SUITE 360	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64798	17041-30001-29983	621 S SPRING ST Unit C	90014	14	127-5A211  12	5144024***	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.04533	-118.25178	03/15/2018 Changes to an approved set of plans. Changes have been made to address field corrections. Exit signs and EM lighting have been recircuited to show the use of building EM generator. *****Previous Work Description*****Plan check Title 24 only in existing building bath spa. Total area: 3,624 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64799	19041-20000-52430	15350 W OXNARD ST	91411	4	177B145   462	2243001031	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.17919	-118.46783	PV3.  Install 193.6 KW DC/175.51 KW AC CEC roof mounted PV system.  (484) modules with (1) 20 KW inverters, (4) 33.3 KW inverter, and a 400A panel.Fees $0.00 Due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64800	10041-10000-17432	335 N JUANITA AVE 1-49	90004	13	138B197   144	5501001003	R4-1	Central	Wilshire	Rampart Village	YES	1927.00	Electrical	Electrical	Commercial			09/02/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.07732	-118.29078	5 STORY, 4 LEVEL OF TYPE V OVER 1 LEVEL OF TYPE I APARTMENT BUILDING: 48 AFFORDABLE  UNITS AND 1 TWO-BEDROOM MANAGER'S UNIT. THERE ARE 7 DIFFERENT TYPES OF UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64801	13041-20000-22722	2323 W LOY LANE	90041	14	162A221   165	5682020014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.13773	-118.21812	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8 KW USING 16 MODULES. POWER OPTIMIZERS. TRANSFORERMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64802	11041-20000-21777	11611 W SAN VICENTE BLVD 500	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	12/07/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	PLAN CHECK T24 ENERGY/EMERGENCY TENANT IMPROVEMENT TO UNIT 500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64803	12041-10000-18527	2716 W OLYMPIC BLVD	90006	10	129B197   223	5078010028	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	09/06/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.05243	-118.29218	remodeling restaurant Hong Kong Banjum # 107plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64804	10041-10000-05386	20124 W SATICOY ST	91306	3	186B113   225	2114005008	C2-1VL, RA-1, RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM			PC Approved	03/24/2010 12:00:00 AM	ADDRESS	34.20813	-118.57184	Energy and Emergency plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64805	11041-20000-12956	3780 S FIGUEROA ST	90007	9	117A201     4	5037029001	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			PC Approved	06/22/2011 12:00:00 AM	ADDRESS	34.01629	-118.28251	Ti in a fitness center. EPC is for T24. (Permit is existing # 11041-20000-11846)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64806	18041-10000-10609	19860 W PLUMMER ST	91311	12	198B113   217	2761040029	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.24253	-118.56627	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64807	15041-10000-16842	2204 E ALCAZAR ST	90033	14	135A225    61	5202004040	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	34.06326	-118.20213	PLAN CHECK FOR TEMPORARY POWER FOR  HEALTHCARE CENTER. PERMIT FEES PAID UNDER APPLICATION NUMBER #15041-10000-07828.  THIS IS PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64808	15041-10001-14888	1100 S HILL ST	90015	14	126A209   128	5139019034	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM			PC Approved	10/07/2016 12:00:00 AM	ADDRESS	34.03989	-118.25984	CHANGES TO APPROVED SET. REVISED LOAD CALCULATIONS FOR ALL FEEDERS AND PANELS BASED ON FIELD CHANGES.ALL CHANGES ARE UNDER DELTA-15 ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64809	19041-10000-47350	20216 W LORENZANA DR	91364	3	171B113   157	2166040005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.16619	-118.57408	0$ FINAL FEES PER AB1414[EPLAN] Revision to 19041-10000-34104 . Added 60A ESS  AC disconect (per LADWP) between Main Service Panel and Tesla Gateway. Removed AC disconnect between 125A Generation load center and 125A ESS load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64810	10041-10000-24237	1441 S WESTWOOD BLVD UNIT# A	90024	5	132B153   939	4324010007	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	03/19/2011 12:00:00 AM	ADDRESS	34.05453	-118.44134	Change out (E) 100 amp to (N) 125 amp 3PH 4W service for a small restaurant. EPC is for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64811	16041-20000-34960	7949 W MCGROARTY ST	91040	7	204B193  1318	2559025003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.25234	-118.30645	Plan check for a PV1 roof-mounted PV system. System size is 6.5 kWac and consists of (26) modules, (26) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64812	13041-20000-29709	23643 W EMELITA ST	91367	3	174B093    61	2041029006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	10/24/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.17636	-118.64218	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 30 MODULES. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64813	17041-20000-13964	206 N WILTON PL	90004	4	138B193   739	5516019012	R1-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Finaled	05/16/2017 12:00:00 AM	ADDRESS	34.07498	-118.31336	Plan check for installation of solar pv array, roof-mounted on a SFD. Interconnect with a 200A MSP.Derating main breaker to 150A. 7.04kW ungrounded system. (22) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64814	18041-10000-15507	881 N ALMA REAL DR #101 & 103	90272	11	126B125    97	4412009014	C2-1VL, P-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	ADDRESS	34.04497	-118.52525	PLAN CHECK FOR POWER AND ENERGY FOR TI - FOR COMMERCIAL MEDICAL OFFICE (PATIENT CARE AREA). WORK INLCUDES  COMBINE SUITE 101 & 103. NO CHANGE IN EXISTING USE OR OCCUPANCY. TOTAL AFFECTED AREA = 3455 SQ. FT. NEW ADDED LOAD IS APPROX. 100ABUILDING PERMIT # 18016-10000-11723	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64815	18041-20000-38748	5321 N TOWNSEND AVE	90041	14	165A225    71	5669006041	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.14532	-118.20141	Plan check for a PV1 roof-mounted PV system. System size is 12.42 kWdc/11.64 kWac and consists of (36) micro-inverters, (36) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64816	19041-10000-35917	3978 S BRIGHTON AVE	90062	8	114B193   183	5036031014	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.01177	-118.30111	PV1, NEW ROOFTOOP MOUNTED SYSTEM, SYSTEM SIZE IS 3.8KWac/3.135KWdc. SCOPE OF WORK IS 11 MODULES (HANWHA Q-CELL 285) WITH OPTIMZERS (SE P320), LEADING TO A CENTRAL INVERTER (SE3800H-US). NO PANEL UPGRADE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64817	18041-10000-42604	445 S FIGUEROA ST Suit# 2625	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	TENANT IMPROVEMENT IN AN EXISTING OFFICE AREA IN SUITE #2625. T-24 ENERGY ONLY. BUILDING PERMIT: 18016-10000-34635	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64818	16041-10001-23894	12249 W VENICE BLVD	90066	11	114B153  1302	4248031002	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.00466	-118.43212	09/14/16Changes to an approved set of plans. All changes are clouded under delta 1. Scope includes removing/replacing lighting fixtures with track lights. Note: Permit is paid under PCIS#16041-10000-23894((((T-24, PC FOR ENERGY ONLY. Change of use from existing pool hall and bar to new restaurant.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2700 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64819	10041-20000-15718	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI IN OFFICE BUILDING ON 17TH FLOOR. P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64820	15041-20001-13190	13262 W VAUGHN ST	91331	7	213B157   268	2524024005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM			PC Approved	06/01/2015 12:00:00 AM	PIN	34.28175739	-118.42187903	Plan check for changes to an approved set of plans. Changes include the downsizing of the AC disconnect, downsizing the wiring from the PV inverter, and lowering the busbar rating of the main service panel to reflect what is to be installed. *****Previous Work Description*****Plan check for PV  roof mouned system solar array 3.8kWac with 1 inverter(SOLAREDGE SE3800A-US) and 19 modules (TROMA TS-260 PAO5A)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64821	18041-20000-16526	320 E 18TH ST	90015	14	123A209   211	5127022018	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.03073	-118.26056	PV2.  Install roof mounted PV system sized 10kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64822	12041-10000-06746	5515 E MARMION WAY	90042	1	151-5A227 175	5468023019	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	07/30/2012 12:00:00 AM	ADDRESS	34.10975	-118.19585	NEW ROOF MOUNTED 2.3KW PV SYSTEM USING ENPHASE MICRO INVERTERS MODEL # 215.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64823	16041-20000-43699	9240 N JORDAN AVE	91311	12	198B105   122	2746012038	[T][Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.23844	-118.60377	Plan check for energy only. TI to existing manufacturing building - electrical equipment wholesale. New lighting (incl. emergency) and receptacles. T24 area: indoor- 34,469sqft; outdoor- 50,138sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64824	11041-10000-03826	3500 W 6TH ST #323	90005	10	135B197  1016	5502030016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/15/2011 12:00:00 AM		Permit Finaled	03/17/2011 12:00:00 AM	PIN	34.06344338	-118.29831795	TENANT IMPROVEMENT AT A BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64825	16041-10000-31073	18338 W VENTURA BLVD	91356	3	171B125   239	2161022035	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.16698	-118.532	Plan check Title 24 only change of use from retail to massage spa. Total area: 960 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64826	17041-10000-42263	1265 S BARRY AVE 1-18	90025	11	129B145   740	4263011011	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			11/21/2017 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.04834	-118.45886	NEW 3-STORY 18-UNIT, TYPE VA APARTMENT BUILDING OVER 1-STORY, TYPE IA SUBTERRANEAN GARAGEVARIANCE TO SEPARATE FA PLANS WAS OBTAINED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64827	19041-10000-15763	5370 E ALHAMBRA AVE Ste D,E,F	90032	14	139-5A235 238	5220031009	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.07649	-118.16861	Energy plan check only for a change of use (Clean Room). scope of work area 573SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64828	16041-20000-31877	14865 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29522	-118.45537	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (11) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64829	16041-20001-27251	6708 N BIANCA AVE	91406	6	180B129   183	2229010035	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.19237	-118.51298	EXPEDITE PER APPLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8 KW INTERCONNETED WITH MSP.  THIS IS TIED INTO AN EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64830	19041-10000-47534	8936 N SEPULVEDA BLVD	91343	7	195B145   138	2654005037	M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Issued	11/19/2019 12:00:00 AM	ADDRESS	34.23322	-118.46735	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64831	18041-10001-28545	1622 N RONAN AVE	90744	15	036B205   440	7414011017	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	33.7956	-118.2731	Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling. Plan Check ONLY. Permit was issued under: 18041-90000-28545	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64832	10041-10000-04906	4001 N RESEDA BLVD Bar	91356	3	162B121    10	2177032021	A1-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01, 1398.02	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.14334	-118.54091	T-24 and emergency lighting plan check for remodeled bar area in existing clubhouse building llighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64833	16041-20000-21973	7941 N KEER DR	91335	12	189B125  1018	2102015091	(T)(Q)RD4-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.21522	-118.53492	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64834	18041-10002-47760	10311 S LA CIENEGA BLVD	90045	11	090B173   271	4129031001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM			PC Approved	09/19/2019 12:00:00 AM	ADDRESS	33.94269	-118.37026	Plan check only. Change to an approved set by adding exterior lighting on the floor plan with an additional lighting area of 5,712-SQ FT. All changes under delta-6 only. (((Power plan check for an auto repair garage. (Hazardous location). Upgrade service to 800A  120/240 3ph, panels, circuits and equipment. No changes to T-24.T-24 paid under master partial permit fees paid under master as well. Master scope: T-24 ONLY, REMODEL & CHG OF USE TO AUTO REPAIR GARAGE. SCOPE OF WORK INCLUDES NEW LIGHTING, PANELS AND RECEPTACLES. SERVICE SIZE IS 400AMPS, TOTAL SQ. FT. 9110))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64835	19041-10000-51241	2049 N BERENDO ST	90027	4	150B197   319	5589024003	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	02/01/2020 12:00:00 AM	ADDRESS	34.10901	-118.29417	(E-PLAN) PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 28  (SPR-A400-G-AC) MODULES, 28  (SPR-A400-G-AC) MICROINVERTERS,  CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE: 11.2 KW DC; 9.772 KW AC. *MAIN BREAKER DERATE TO BE PULLED UNDER SEPERATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64836	19041-10000-06131	1655 E 27TH ST	90011	9	115-5A213  32	5117003037	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.01239	-118.24368	PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 378 MODULES (HYUNDAI 370) , 189 OPTIMIZER (SE P800, 2 MODULES PER OPTIMIZER) AND 2 CENTRAL INVERTER (SE100K-US AND 33.3K-US).  SYSTEM SIZE IS 139.86KWdc and 133.3KWac.PERMIT IS $ DUE TO AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64837	18041-20000-03903	9514 N RESEDA BLVD ste 8	91324	12	198B125    31	2764008020	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.24339	-118.53587	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor lighting only.this is plan check only.permit fees paid under application number 17041-10000-35894	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64838	10041-10000-23342	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM			Permit Finaled	02/25/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	REVISIONS IN THE FIELD--REFEED NEW PANEL EP FROM NEW TRANSFORMER TR-EP (15KVA) WHICH IS SUPPLIED FROM PANEL EH2UX; PANEL EP IS LOCATED OUTSIDE THE NEW FA CONTROL BLDG; FUSED DISCONNECTS  AND TRANSFORMER LOCATED IN ELECTRICAL ROOM 1814; PNL EH2UX  IS LOCATED ON THE FLOOR ABOCE RM 1814 ( REFERENCE TEMP LOADING DOCK/ NEW FIRE ALARM CONTROL BLDG )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64839	17041-20000-16247	12030 W RIVERSIDE DR	91607	2	168B165   566	2355014020	P-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Issued	05/16/2017 12:00:00 AM	ADDRESS	34.15745	-118.39535	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64840	14041-20000-09669	13610 W STRATHERN ST	91402	6	189B157   435	2214026021	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Apartment			04/11/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.21519	-118.42917	NEW CONSTRUCTION, APARTEMNT BUILDING (34 UNITS) high rise residential. pc for power and energy.fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64841	17041-20002-36046	9715 N SHADOW ISLAND DR	91040	7	201B181   141	2545011006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.24912	-118.34256	01/18/2018 Changes to an approved set of plans. All changes have been clouded. Changes include the removal of the Tesla PowerWall from the PV system.*****Previous Work Description*****Plan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.5.2kW unground pv system. (21) 315W pv modules. (1) 5kW Tesla Powerwall 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64842	15041-20001-15771	2248 N PANORAMA TER	90039	4	148-5A205 358	5432025014	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.10023	-118.2696	Changes to an approved set of plans. Changes are only to the PV modules layout.*****Previous Work Description*****Plan check for PV roof monted system. System size: 3.6kW with 17 modules and 17 microinverters connected to 200A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64843	15041-10000-26520	21650 W OXNARD ST STE 500	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM			PC Approved	08/14/2015 12:00:00 AM	ADDRESS	34.17901	-118.60107	PC FOR ENERGY ONLY, T-24. SCOPE OF AREA INCLUDES NEW OFFICES AND CORRIDOR LIGHTS. TOTAL SQ. FT. 915	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64844	10041-20000-20309	5200 W WILSHIRE BLVD	90036	4	132B181    30	5507024010	[T][Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			10/13/2010 12:00:00 AM	10/19/2011 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.06194	-118.3435	NEW MIXED USE APT (478 UNITS) 6 stories	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64845	16041-20000-00879	8813 N MURIETTA AVE	91402	6	195B153   648	2639023020	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.23061	-118.44213	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW, ungrounded system. (10) 335W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64846	18041-20000-17212	350 S GRAND AVE 30th Floor	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only. Project site is the common area corridors, restrooms, and elevator lobbies in an existing commercial high-rsie building. Project scope is a tenant improvement. Total lighting area = 2,200 sq. ft.Note: Building permit has been issued under 18016-20000-10410	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64847	19041-10000-45798	5101 S WESTERN AVE	90062	8	111B193  1311	5005028014	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Issued	11/07/2019 12:00:00 AM	ADDRESS	33.99677	-118.30908	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLYOUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64848	13041-10000-36049	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM			PC Info Complete	06/10/2014 12:00:00 AM	ADDRESS	33.94558	-118.4039	pc for power and energy. T2 REDUNDANT ELEVATOR PRODUCT WILL CONSTRUCT A NEW 3-STOP PASSENGER ELEVATOR, CONNECTING ARRIVALS, DEPARTURES & CONCOURSE LEVELS, WITH NEW ELEVATOR LOBBY AREAS AT EACH LEVEL.  NEW ELEVATOR PIT, STRUCTURAL FRAMING...(see additional comments)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64849	19041-20000-41385	11825 W TERRA VISTA WAY #133	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64850	14041-10002-00401	5107 W HAROLD WAY	90027	13	148-5A195 238	5544013008	RD1.5-1XL	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.09947	-118.30083	PC FOR CHANGES TO APPROVED SET UNDER DELTA 4 ONLY. SCOPE INCLUDES CHANGES TO BREAKERS AND FEEDERS TO REFLECT FIELD INSTALL. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64851	19041-20000-44858	854 W DOWNEY WAY	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	05/26/2020 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.02013	-118.28757	Plan check for Title 24 energy only new lighting, control wiring. Total area: 5281 sq ft.Connected load less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64852	16041-20000-31870	12348 N VILLAR WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.29508	-118.45496	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64853	14041-20000-00123	1457 W COLORADO BLVD	90041	14	162A227   402		[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.13954	-118.1965	PV2 COMMERCIAL ROOF TOP SOLAR. TOTAL SYSTEM SIZE 56 MICROINVERTERS USING THE ENPHASE 250. TO BE VERIFIED WITH TEST LAB APPROVAL. TOTAL SIZE 13.4KW AC. TOTAL OF 2 SYSTEM INTERCONNECTIONS. TOTAL SERVICE SIZE IS 1200A. PLAN CHECK TO EXTEND TO ENTIRE SERVICE. use of transformer to make compatable 3phase connection	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64854	14041-20000-02117	23255 W ARMINTA ST PV1	91304	12	189B093   419	2020024004	RE11-1	South Valley		West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.21337	-118.63435	New ungrounded PV System for an existing single family dwelling with two inverters.  System size is 7.84 KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64855	13041-20001-34333	9320 N DEBRA AVE	91343	12	198B137   460	2676006017	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.23991	-118.4904	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0 KWAC. 3 STRINGS FOR 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64856	15041-20000-19060	12418 N GLADSTONE AVE	91342	7	219B161   241	2525019066	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	PIN	34.29583071	-118.4110579	Plan check for power only. Project site is an existing commercial building. Project scope is the addition of load to existing distribution equipment. Submitted per applicant request. (Phase 3 of project)Note: Phase 2 of project is under application number 15041-20000-17742	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64857	14041-20000-32320	5815 W SUNSET BLVD 306	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.09822	-118.31613	Plan check for energy only. TI to storage suite on 3rd floor of low-rise office building. New lighting (incl. emergency). 1,147sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64858	13041-10000-02119	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM	01/28/2013 12:00:00 AM		Issued	01/28/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	PLAN CHECK FOR FIRE ALARM SYSTEM 1 PANELS AND 44 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64859	13041-10000-26451	4132 N KNOBHILL DR	91403	4	165A151   267	2275002052	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.14504	-118.44788	PV1.  Install 8.25 kW DC roof-mounted solar array, interconnect with main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64860	18041-10001-37672	1533 N SCHRADER BLVD Membrane-Bldg	90028	13	147A187    32	5547018901	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.09901	-118.33257	CHANGES TO AN APPROVED SET OF PLANS NOTED UNDER CLOUDED AREAS. CHANGES INCLUDE THE ADDITION OF EXHAUST FANS AND ELECTRIC WATER HEATERS.  ______________________________________________________New emergency temporary shelter for the homeless consisting of two state certified modular buildings-Admin Bldg; Hygiene Bldg  and newly constructed Membrane Bldg-This application is for the Membrane building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64861	16041-20000-38328	14467 W BRAND BLVD	91340	7	210B149   134	2613021031	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.2756	-118.44855	PV1.  Install 8.45 kW DC roof mounted grid-tied PV system.  (26) modules with (1) 7.6 kW rated central inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64862	15041-10000-33656	3287 W WILSHIRE BLVD Unit A	90010	10	135B197  1219	5502026021	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			10/09/2015 12:00:00 AM			PC Approved	10/26/2015 12:00:00 AM	ADDRESS	34.06197	-118.29379	Title 24 plan check only.  Total area = 2,155 sq. ft.     T.I. to existing beauty salon.  New 200 A panel and new 100 A panel with associated loads.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64863	10041-10000-10992	5555 E VALLEY BLVD Bldg 325	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM			PC Approved	06/25/2010 12:00:00 AM	ADDRESS	34.07489	-118.16218	Lighting for partial 1st, 2nd and 3rd floors of building 325.  T-24 and emergnecy lighting.  The engineer indicates that the lighting control is changed from the previous approval.  However, the LTG-5C form may require revision based on proper area classification.  Existing permit 09041-10000-24296.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64864	19041-20000-03566	12820 W PANAMA ST	90066	11	105B157   395	4223008012	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	33.98477	-118.42659	Parking lot pole lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64865	12041-10000-14380	5009 N ORRVILLE AVE	91367	3	171B093   732	2047012032	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	07/27/2012 12:00:00 AM	ADDRESS	34.16217	-118.643	Plan check for PV system. 7.65 kw DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64866	19041-20001-06400	18822 W PARTHENIA ST	91324	12	195B121   389	2785001081	[Q]M1-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	06/17/2019 12:00:00 AM	ADDRESS	34.22808	-118.54338	EXPEDITED PLAN CHECK FOR NEW 73.8KW AC ROOFTOP MOUNTED PV SYSTEM ON EXISTING COMMERCIAL LOWRISE BUILDING. SCOPE OF WORK INCLUDES (267) PV MODULES, (54) SE-P320 OPTIMIZERS, (107) SE-P730 OPTIMZERS, (1) 75KVA XFMR, (2) 30KW AC INVERTERS, (1) 10KW AC INVERTER, AND (1) 3.8KW AC INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64867	14041-20000-32578	4956 N GLORIA AVE	91436	5	168B141   141	2261013044	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	PIN	34.15984491	-118.47846576	PV1. ROOFMOUNTED SOLAR SYSTEM. total of 6.45kw ac using standard plan. system uses microinverter enphase m215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64868	18041-10003-33164	108 S FREMONT PL WEST	90005	4	132B185   290	5090018010	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.05945	-118.32826	void for fee testing only. Change to approved set by changing the model of PV module and change microinverter to (2) central inverter. All changes under clouded area.Applicant prefer original plan checker J.Hua(((NEW ROOF MOUNTED 16.8 KW PV SYSTEM WITH 56 MODULES and MICROINVERTERS ON A SINGLE FAMILY HOME.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64869	16041-30002-17873	3833 N WINFORD DR	91356	3	162B121    39	2177047022	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM			PC Approved	07/12/2016 12:00:00 AM	ADDRESS	34.14068	-118.55007	07/12/2016 Changes to an approved set of plans. AC disconnect has been changed to a fusible AC disconnect. The rest of the PV system has remained the same. *****Previous Work Description*****PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 21KW INTERCONNECTED WITH MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64870	16041-20000-37702	3033 E WASHINGTON BLVD	90023	14	118-5A221  84	5169019008	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.01666	-118.21418	remove existing hid fixtures and replace with new led fixtures indoor and outdoor.  plan check for energy 154000 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64871	19041-20000-07660	18226 W VENTURA BLVD	91356	3	171B125   309	2181010028	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.16616	-118.52995	TITLE 24 PLAN CHECK FOR EXISTING LOW RISE COMMERCIAL BUILDING POWER AND ENERGY. LIGHTS AND RECEPTACLES ONLY. TOTAL SQUARE FOOTAGE = 2752 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64872	12041-20000-23782	13907 N EMIR AVE	91342	7	228B153    39	2582012007	RS-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	01/25/2013 12:00:00 AM	ADDRESS	34.32532	-118.43346	7.5kw rooftop system for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64873	16041-20000-40907	13967 W ROSCOE BLVD	91402	6	192B153   718	2638037018	R1-1, RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.2218	-118.4376	replace existing hid fixtures with new led exterior lights.  this plan check includes fixtures in the sports fields which are t-24 exempt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64874	19041-20001-30973	13165 W DEL SUR ST	91340	7	216B157    65	2524004007	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	34.28516	-118.41972	1024-2019 Changes to an approved set of plan, Changes include PV module layout. Changes has been clouded. Plan check only, permit covered under master application.Fees $45.83 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64875	18041-10000-47965	832 N DOMINGUEZ AVE	90744	15	030B209    22	7425011805	[Q]MR2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	33.78151	-118.25132	NEW PARKING LOT. NEW 200 AMP SERVICE, CIRCUITS & LIGHTS. T-24 ENERGY ONLY FOR EXTERIOR LIGHTING. 16,384 SQR FT. BUILDING PERMIT: 18020-10000-03711	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64876	19041-20001-33022	676 N SPRING ST	0	1	133-5A215 212	5408013025	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	PIN	34.05922278	-118.2378601	Revisions to approved plans.  Miscellaneous clouded revisions related to lighting system. (((TENANT IMPROVEMENT FOR RETAIL TITLE 24 ONLY. TOTAL AFFECTED AREA 3926 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64877	09041-10001-07273	5557 E VALLEY BLVD	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Public Safety Only			02/05/2010 12:00:00 AM	02/05/2010 12:00:00 AM		Permit Finaled	01/23/2012 12:00:00 AM	ADDRESS	34.07723	-118.16241	Delta 7 revision to approved plan.  Remove and added devices. Plan check for new Fire Alarm System for 3-story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64878	13041-10002-18931	600 S SAN VICENTE BLVD	90048	5	135B173   644	5510022043	CR-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.06586	-118.3728	(((4/4/2014- CHANGES MADE TO APPROVE SET OF PLANS. CHANGES ONLY COVER LIGHTING CHANGES. T24 CALCULATIONS TO BE VERIFIED)))T24 only. Adding 28 new light fixtures. CHANGE OF CONTRACTOR WAS DONE ON 10001 APPLICATOIN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64879	15041-10000-14486	17547 W VENTURA BLVD	91316	5	171B129   351	2257008048	(Q)C4-1VL, (Q)P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM			PC Approved	05/12/2015 12:00:00 AM	ADDRESS	34.16196	-118.51589	ENERGY PLAN CHECK FOR AN EXISTING RESTAURANT; SCOPE INCLUDE NEW LIGHT AND RECEPTACLE OUTLETS. PERMIT FEE IS PAID UNDER EXPRESS PERMIT # 15041-10000-12918.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64880	11041-20000-26121	733 N BROOKTREE ROAD	90272	11	126B129   428	4409022001	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2011 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.04208	-118.51506	Submittal 2: changes to approved set of plans. Relocation of AC disconnect (moved downstream of dedicated PV panel).New 15.8 KW roof mounted PV system, with battery back up, for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64881	13041-10000-01982	1300 E FACTORY PL	90013	14	126A215   235	5164008031	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.03904	-118.23584	First time tenant for a restaurant space.  3 story building.  Energy and power.  2734 sq ft total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64882	15041-20001-20874	19231 W VICTORY BLVD #150	91335	3	180B117   799	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	34.18678	-118.55214	3.21.2016 - Plan check for modifications to approved set. Change light fixture types, update Title-24 calculations and fixture schedule to reflect changes. No longer adding new circuits to (E) Panel B. All new circuits are now only being added to (E) Panel C. Changes clouded.---Plan check for power and Title-24.  Total area = 2,774 sq. ft.  T.I. to existing medical Suite with 9 Exam rooms.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64883	15041-10000-07191	1547 N TOWER GROVE DR	90210	5	147B157   241	4356015022	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.09849	-118.42597	PERMIT FEEE IS CAPPED TO ZERO PER SENATE BIL # 1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.6KW INTERCONNECTED WITH MSP.(46) MODULES: KYOCERA KU2606XPA(2) INVERTERS: PVI-3.0-OUTD-S-US-Z-A,(1) PVI-3.6-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64884	11041-20000-23244	1990 S BUNDY DR Ste 410	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/31/2011 12:00:00 AM			PC Approved	10/31/2011 12:00:00 AM	ADDRESS	34.03419	-118.45559	Creating new offices in existing space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64885	18041-10000-28267	9775 S AIRPORT BLVD	90045	11	093B169   276	4124029040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	33.9478	-118.38617	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64886	14041-10000-17154	3325 W WILSHIRE BLVD Suite 1100	90010	10	135B197  1123	5502027010	C4-2, R5-2, R5P-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.06195	-118.2949	Title 24 plan check only.  Total area = 14,465 sq. ft.Remodel of existing office space.  Moving partition walls and lighting fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64887	15041-20000-43351	12400 W JEROME ST	91352	6	195B165    25	2629022001	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.23504	-118.40303	PV1, rooftop solar installation 4.2kW AC system(14) Sunpower E-20-327(1) ABB PVI-4.2-OUTD-USstandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64888	15041-20001-16579	5426 N BECKFORD AVE	91356	3	174B121   645	2163018013	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.16994	-118.55107	PC FOR DERATE MAIN. INCLUDED PERMIT FEE FOR MONITORING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64889	14041-20000-14221	15300 W VENTURA BLVD	91403	4	168B145   952	2276039007	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.15368	-118.4665	TI to (E) single-story commercial building for new restaurant.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64890	12041-10000-10650	2970 W OLYMPIC BLVD #305	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	Plan check power and energy for new medical office, first-time tenant. Suite #305. Not checked for OSHPD 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64891	18041-20000-07182	2221 S MAIN ST	90007	9	121-5A205  86	5126033007	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	34.02785	-118.26697	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,552 sq. ft.Note: Building permit has been issued under 17016-20000-29786. Electrical permit fees have been paid for under 18041-70000-02763.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64892	15041-20001-01612	12945 N GLENOAKS BLVD	91342	7	222B149   490	2505018060	RA-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM			PC Approved	01/24/2015 12:00:00 AM	ADDRESS	34.30568	-118.44756	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.2kW (3.6+3.6). Ungrounded system.28  327W pv modules across 4 strings (7+8 on inv1; 6+7 on inv2).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64893	15041-20000-42513	18616 W KENYA ST	91326	12	210B125   267	2717010025	RE11-1	North Valley	Northridge	Northridge West	YES	1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.27308	-118.53818	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac/4.845KWdc. (19)MODULES-TRINA SOLAR TSM-255 PD05.05(1)ABB PVI-3.8-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64894	17041-10000-39200	1417 E 15TH ST	90021	14	121-5A213 345	5130012011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	04/05/2021 12:00:00 AM	ADDRESS	34.02529	-118.24466	PC for power and energy for two story office/warehouse building. Installing new 600A service and service panel, two subpanels, equipment, receptacles and lights. Building 14010-10000-02791Building# 14010-10000-02792	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64895	12041-10002-22730	500 W WORLD WAY Delta-Term 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	(((5/14/14 plan check for revised set of plans.  Added new loads and revised Title 24. Load calcs and t24 to be verified. All changes have been clouded.)))CHANGES TO PERMITTED SET  OF PLANS. ORIGINAL SET OF PLANS INCLUDED NEW DISTRIBUTION BOARDS AND LOADS THAT WERE THE RESPONSIBILITY OF THE LANDLORD-LAWA. THESE ARE NOW SHOWN TO BE EXISTING AND TENANT DELTA LOADS ARE SUPPLIED FROM TENANT DISTRIBUTION BOARDS((((((((((((Renovation at the Delta offices at Terminal 5 at LAWA. Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64896	12041-10000-30148	17329 W SAN JOSE ST PV1	91344	12	207B133   751	2733026***	(Q)RD6-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.26133	-118.5121	PV1:  New 5.52 KW roof mounted PV system for a single family residence.  Installing 23 modules, 1 transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64897	16041-10001-41245	26640 S WESTERN AVE unit L	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM			PC Approved	12/14/2016 12:00:00 AM	ADDRESS	33.78015	-118.30862	PC  FOR RESTAURANT T.ITOTAL AFFECTED AREA 1125 SQ.FTSCOPE INCLUDES LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64898	18041-10002-03631	1457 N VAN NESS AVE	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM			PC Approved	09/10/2018 12:00:00 AM	ADDRESS	34.09731	-118.31598	DELTA 8 CHANGES TO APPROVED PLANS. ADD 100A MCB ON PANEL L3C1E PER FIELD INSTALLATION. *This is plan check only, permit is covered under master #18041-10000-03631*<<<Plan check for power and energy. Project site is an existing commercial building. Project scope is a first time tenant/tenant improvement. Total lighting area = 79,217 sq. ft.>>>Note: Building application has been generated under 18016-10000-02052	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64899	15041-10000-08269	7502 N WHEATLAND AVE	91352	2	189B177   393	2466031026	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.20703	-118.36178	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACE EXISTING FIXTURES WITH LED LIGHTING.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64900	11041-10000-20312	10660 N SEPULVEDA BLVD	91345	7	207B145   328	2649011042	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.26431	-118.46697	T.I. to an existing 7-Eleven. PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64901	18041-10000-42533	350 S GRAND AVE #D-1	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	Energy plan check for a commercial office and retail TI. located in a high rise building. Scope includes new lighting and equipment with a total area of 1749-SQ FT.B#18016-10000-35931	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64902	16041-20002-17172	11428 W SHERMAN WAY	91605	2	183B169   683	2320001022	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM			Verifications in Progress	08/04/2017 12:00:00 AM	ADDRESS	34.20103	-118.37983	Revisions to previously approved plans.  Approval for delta-1 revisions dated 06/02/17.  Added load calculations for MDP-1/MDP-2.  SLD revisions to match field conditions.  Load shedding/transfer detailed on SLD.  Miscellaneous changes on power/lighting plans. (((CHANGE OF USE FROM WAREHOUSE/OFFICE TO RETAIL. NEW COSTCO. NEW ELECTRICAL SYSTEM. FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE INCLUDES ONE NEW 5000A 480/277V 3 PHASE 4 WIRE SERVICE, NEW DISTRIBUTION  PANELS, CIRCUITS AND LIGHTING. PERFORMANCE METHOD IS BEING USED. TOTAL AFFECTED AREA IS 616833 SQ. FT. Building application ref no.: 16016-10000-09606)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64903	18041-20000-18348	1400 N GAFFEY ST	90731	15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM			PC Info Complete	06/07/2018 12:00:00 AM	ADDRESS	33.75723	-118.29183	Plan check for Title 24 Energy only in existing outdoor space. Total area: 2091 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64904	16041-10000-44417	170 S BIMINI PL	90004	13	138B197  1128	5501013027	P-1, [Q]C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.07114	-118.29039	*zero permit fee per California Senate Bill 1222PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 53.76KWdc / 48.0KWac.(192)MODULES-LG LG280S1C(2)INVERTERS-SMA STP 24000TL-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64905	14041-20000-23021	6368 S ARIZONA CIR	90045	11	105B165   677	4110014007	[Q]M1-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	09/09/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	33.9802	-118.39789	PC FOR T24 ENERGY ONLY. NEW LIGHITNG. OFFICE AREA. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64906	11041-20000-22367	6845 N VINELAND AVE Bldg A	91605	2	183B173   213	2319005022	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			10/19/2011 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.19522	-118.37051	The plan shows a auto repair facilty associated with an auto sales office.  The auto sales office is new and will be permited on a separate application.  The repair facility is a remodeled mfg building.  Checked for T24 lighting compliance and electrical power, and hazardous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64907	17041-20001-40458	605 W 7TH ST	90017	14	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM			PC Approved	05/17/2018 12:00:00 AM	ADDRESS	34.04758	-118.25677	Recheck of lost set of plans.  (((Change of use from retail to restaurant.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64908	14041-10001-10508	624 W ISABEL ST	90065	1	144A221    75	5453018014	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1853.10	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.09042	-118.22052	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, INTERCONNECT TO THE MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(14) MODULES: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64909	12041-20000-13919	7361 N LAUREL CANYON BLVD	91605	6	186B165   260	2307022010	M2-1VL, P-1VL, R1-1, R2-1	South Valley	North Hollywood	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	07/06/2012 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	ADDRESS	34.20451	-118.39671	Plan  Check per customer request for a new transformer pad for tent building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64910	19041-20000-53038	22850 W ERWIN ST	91367	3	177B097   298	2039014010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	34.18267	-118.62513	PV1. INSTALL 16.5 KW DC ROOFMOUNTED PV SYSTEM WITH (50) MODULES, OPTIMIZERS AND (2) INVERTERS(SE7600H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64911	15041-10000-25982	1246 W BIG CANYON PL	90732	15	015B193   109	7452027014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	33.7397	-118.30347	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6KWDC. 1 INVERTER AND 23 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64912	19041-20000-03910	2131 S DUXBURY CIR	90034	5	126B165   121	4309009021	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Issued	03/06/2019 12:00:00 AM	ADDRESS	34.04418	-118.39609	Plan check for PV roof mounted system, System size: 9.9KW DC, with 30 PV Modules and 1 inverter(7.6KW) connected to 600A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64913	10041-20000-15852	1760 N GOWER ST	90028	13	148-5A189  24	5545001022	R4-2	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	10/19/2010 12:00:00 AM	ADDRESS	34.10315	-118.32222	installing lighting only. energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64914	19041-10000-52931	12001 W CHALON ROAD	90049	11	141B141     5	4429003033	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	04/01/2021 12:00:00 AM	ADDRESS	34.08469	-118.4849	per AB#1414 & SB# 1222 $0.00 FEES[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 80KWdc (60.8KWac & 72.95KWcec-ac) USING 200 JKM400 MODULES, 200 SE P400 POWER OTIMIZERS & 8 SE-7600A-US CENTRAL INVERTERS. CONNECTED TO AN EXISTING SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64915	19041-10000-18237	346 S LA BREA AVE	90036	4	135B181   343	5507008015	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Info Complete	07/11/2019 12:00:00 AM	ADDRESS	34.06752	-118.34382	T-24 PLAN CHECK FOR A TI TO A CHANGE OF USE FROM RESTAURANT TO FITNESS STUDIO, OFFICE AND STORAGE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 8443 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64916	18041-20001-35538	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM			PC Approved	05/01/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	05/01/2019 Plan check for Title 24 only. Project site is part of the 2nd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,892 sq. ft.*****Original Work Description*****Replace 26 80 watt fluorescent fixtures with 35 watt LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64917	19041-20000-20171	9227 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	03/30/2021 12:00:00 AM	ADDRESS	34.23663	-118.38075	New 3-story transfer station and material recover facility building.  (2) 5000A 480Y/277V 3ph-4w services.  Plan check for power and energy.  Building permit under 17010-10000-04979.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64918	11041-10000-16203	12300 W WILSHIRE BLVD # 310	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	12/14/2011 12:00:00 AM	ADDRESS	34.04245	-118.46922	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64919	11041-20000-17691	800 W 6TH ST 310	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	34.05011	-118.2577	office t.i.EnergyFire/ Life safety 11041-10000-18029exist. permit 11041-90000-16797	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64920	16041-10002-45781	380 WORLD WAY Tunnel E	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM			Reviewed by Supervisor	04/19/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	"DCN-102 CHANGES TO APPROVED PLANS. <<<<02-06-2018 Changes to an approved set of plan LAX Project 5 Midfield Satellite Concourse North(MSCN) TUTL-E. Changes include from feeder to busway, circuit revision, lighing ajustment. Changes apply to delta 1 only. >>>>*****************************Previous Work Description**************************Full Plan check. Addition to (E) Bradley West Terminal. Install new lighitng, power, and emergency power to LAX MSC TUNNEL-EAST building. Total area: 37000 sq. ft.  *Scope and plan check is noted ""UNDER TUNNEL EAST PROJECT"" B#16014-10000-02498"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64921	15041-10000-30296	945 S HUDSON AVE	90019	4	132B185   486	5090006009	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Expired	11/21/2017 12:00:00 AM	ADDRESS	34.05779	-118.33477	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.791KW. 33 MODULES AND 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64922	11041-10000-14125	5711 N SEPULVEDA BLVD	91411	4	174B145   168	2243002021	CM-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.17435	-118.4665	TI TO A STOCK ROOM/STORAGE AREA AT A TARGET STORE.  PLAN CHECK IS FOR T-24 ENERGY ONLY.   FULL PLAN CHECK MAY BE REQUIRED SUBJECT TO INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64923	18041-20000-20768	15031 W RINALDI ST SUITE 150	91345	7	213B145    64	2664022028	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.27918	-118.46029	Plan check for Medical office T.I for City of Hope. Total area: 282 sq ft.B#18016-20000-17830	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64924	19041-20000-33645	10900 S VERMONT AVE	90044	8	088-5A199 126	6075001017	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2412.02	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	33.9371	-118.29135	INSTALL (46) NEW FIRE ALARM DEVICES AND (1) PANEL FOR HOMELESS SHELTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64925	18041-20000-27024	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	New IDF rooms, expansion of MDF room, and new distribution to supply data/server equipment in (E) commercial shopping center.  Minor distribution upgrades/replacement transformers for increased load.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64926	13041-10000-35767	1755 N HIGHLAND AVE 5TH FLOOR	90028	13	148-5A185 403	5548004***	C4-2D-SN, [Q]R4-1VL	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.10323	-118.33897	PLANCHECK FOR T24 ENERGY ONLY FOR FITNESS ROOM IN THE 5TH FLOOR OF LOEWS HOTEL. HIGH RISE. 1740 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64927	17041-10000-19764	13187 N SAN FERNANDO ROAD	91342	7	225B141   201	2604004026	[Q]C2-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.31041	-118.47403	PLAN CHECK FOR ENERGY ONLY FOR NEW 2-STORY OFFICE(TOTAL AFFECTED AREA = 3000 SQ.FT).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64928	12041-20000-12915	9355 N SAN FERNANDO ROAD	91352	6	198B165   115	2631001020	C2-1VL, RA-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	06/11/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.23876	-118.3935	Install new 600 ampere service to replace existing 200 ampere service.  No change in load or circuits in the building.  New 200 ampere panel to supply existing loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64929	19041-10000-21530	8212 S WESTERN AVE	90047	8	099B193  1377	6034016003	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Info Complete	10/22/2019 12:00:00 AM	ADDRESS	33.96413	-118.3088	FULL PLAN CHECK FOR A CHANGE OF USE FROM DRY CLEANING TO CONVENIENCE STORE ( 7-ELEVEN ) IMPROVEMENT. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 3000-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64930	11041-20000-07671	14117 W HUBBARD ST	91342	7	219B153   199	2508027019	(T)(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	04/15/2011 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	ADDRESS	34.29849	-118.44081	plan check was approved expired under permit # 080412000021199	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64931	17041-10000-25464	13713 W OSBORNE ST	91331	6	198B157   619	2642022003	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.23796	-118.43204	PLAN CHECK FOR ROOF MOUNTED SYSTEM - SYSTEM SIZE = 6KVA CONSISTING OF 1 INVERTER (SE6000A-US) AND 27 PANELS (CANADIAN SOLAR CS6K)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64932	10041-10002-06988	14320 W AETNA ST	91401	6	177A151    91	2240007901	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	02/09/2011 12:00:00 AM	ADDRESS	34.18006	-118.44473	INSTALLING  a UPS , 5     150 amps feeders and 800 amps panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64933	16041-20000-13681	530 E WHEELING WAY	90042	14	150A231   307	5301012007	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1837.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	05/28/2016 12:00:00 AM	ADDRESS	34.10346	-118.18434	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER STANDARD PLAN. SYSTEM SIZE: 2.4KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64934	18041-20000-02991	221 N FIGUEROA ST suite 1450	90012	14	133-5A211 255	5161006909	C4-2D, [T][Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.05882	-118.25099	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64935	12041-20000-30816	1233 N MCCADDEN PL	90038	4	144B185   208	5532005040	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.09379	-118.33758	Plan check for energy only. No emergency lighting. Classrooms, office and outdoor lighting.  Applicant indicates no emergency lighting required.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64936	15041-20001-29987	9697 W WENDOVER DR	90210	5	156B157   248	4385022006	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2015 12:00:00 AM			PC Approved	10/09/2015 12:00:00 AM	ADDRESS	34.12419	-118.42935	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is (12) kWac and consists of (2) inverters, (1) load center, and (47) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64937	14041-20001-02830	6960 N RUBIO AVE	91406	6	183B137   280	2225006034	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.19729	-118.49548	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TRANSFORMERLESS INVERTERS USING POWER OPTIMIZERS. 7.6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64938	13041-20001-06147	23843 W WELBY WAY	91307	12	180B089   109	2034001033	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.19274	-118.64616	"Changes to approved set of plans. Reduction of two panels and associated power optimizers. Reduction of inverter to 3.8kW.rooftop pv system for an existing single family residence.  System is ungrounded and has additional DC power optimizers.  Misc. permit is for ""Power Optimizers""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64939	18041-30000-15542	5300 W MELROSE AVE Suite 400	90038	4	141B189   384	5522001007	(Q)M1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.08336	-118.31616	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,637 sq. ft.Note: Building application has been generated under 18016-10000-11975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64940	15041-20001-37562	10443 N LARWIN AVE Unit 2	91311	12	207B101   276	2723012***	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			11/06/2015 12:00:00 AM			PC Approved	11/17/2015 12:00:00 AM	ADDRESS	34.2601	-118.61384	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (20) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64941	11041-10001-01682	11976 W CULVER BLVD 1-124	90230	11	108B161   154	4218007025	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Apartment			09/15/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	33.99512	-118.4173	New 124-units affordable housing 4-storie over parking garage on grade. EPC is for power & Energy. (T24 fee is not included)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64942	18041-20000-47639	1901 S AVENUE OF THE STARS 370 & 380	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM			PC Info Complete	12/17/2018 12:00:00 AM	ADDRESS	34.05949	-118.41705	Plan check for Title 24 only in existing office space T.I. receptacle and lighting. Total area: 3633 sq ft. B#18016-100000-36728	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64943	11041-10001-21845	8746 N CANBY AVE	91325	12	195B125   699	2769025023	[Q]C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.23002	-118.53466	[[[[10/16/14 CHANGES TO APPROVED SET. DELTA 1 CHANGES ONLY. REMOVING EQUIPMENT IN KITCHEN. REMOVING LOADS FROM PANEL K1 AND K2. ]]]]]Existing building.  Building used to be a private school and is being converted to a rescue mission.  New switchboard, panels, lighting, etc.  Plan check is for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64944	19041-20000-39930	13352 W VAN NUYS BLVD	91331	7	207B157   558	2620006025	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Issued	10/02/2019 12:00:00 AM	ADDRESS	34.26464	-118.42379	T24 PLAN CHECK FOR TI REMODEL OF EXISTING COMMERCIAL LOW RISE. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 1135 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64945	18041-10001-47136	611 E FLOWER AVE	90291	11	111B145   985	4240011022	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	01/24/2019 12:00:00 AM	ADDRESS	33.99867	-118.4709	EXPEDITE PER APPLICANT REQUEST.(((PV1, INSTALL 13.5 KWH ENERGY STORAGE SYSTEM AND 3.25 KWDC PV ARRAY, WITH 10 MODULES(SC SC325), AND 1 INVERTER(UNO-DM-3.3-TL-PLUS-US-SZ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64946	12041-20000-15890	14006 W RIVERSIDE DR STE#: 111	91423	2	168B153   454	2269025***	(Q)C2-1L, (Q)PB-1L, C2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	T.I. to existing building in the tenant space (Children Place).  Install general/emergency lighting with Tailor Method.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64947	18041-20000-03253	5860 W JEFFERSON BLVD	90016	10	120B173  1729	4205027022	CM-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	01/29/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.02504	-118.37633	New fire alarm system for 2-story commercial office building.  New FACP with (124) signaling-line/notification devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64948	14041-10000-10914	888 S OLIVE ST	90014	14	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	10/07/2016 12:00:00 AM	ADDRESS	34.04383	-118.25785	FA FOR HIGH RISE RESIDENTIAL CONDOMINIUMS.34STORY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64949	15041-20001-02777	12476 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	03/01/2015 12:00:00 AM	ADDRESS	33.97888	-118.41041	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64950	08041-10001-27348	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM			PC Approved	09/01/2010 12:00:00 AM	PIN	33.93847109	-118.41935625	Suppl. application for changes to the approved plans.  The two 1.5MVA  & 2MVA DWP transformers were replaced with one 3.75MVA, 34.5KV:480V, 3Ph. LAWA - New Taxiway at LAX.  Permit is for new ckts, new panels, new services for RON Apron.  P/C is for Power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64951	16041-10000-42708	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.94502	-118.40714	T-24, PC FOR ENERGY ONLY. CHANGE A PORTION OF A RETAIL TO A HOLDROOM SPACE. TI FOR 2 ROOMS AT 30, CONCOURSE LEVEL. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3294 SQ. FT. B#16016-10000-11956	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64952	13041-10000-23348	3356 S MCLAUGHLIN AVE	90066	11	117B153   461	4249006024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.01779	-118.4325	INSPECTOR TO VERIFY IF EQUIPMENT IS SUBJECTED TO VEHICULAR TRAFFIC AND IF REQUIRED PROTECTION(BOLLARDS). PV1 , INSTALLING 5.2KW DC INCLUDING SOLAR ARRAY MOUNTED ON GARAGE AS SUPPLEMENTAL ELECTRICAL SUPPLE SYSTEM CONNECTED TO ULITITY THROUGH THE SERVICE EQUIPMENT AS SUPPLEMENTAL POWER SUPPLY IN SINGLE STORY HOUSE.SYSTEM TYPE: UNGROUNDED(20) 260W MODULES(20) 215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64953	13041-20000-24679	611 N LARCHMONT BLVD	90004	4	141B189   584	5523012026	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/14/2013 12:00:00 AM	ADDRESS	34.08205	-118.32385	New fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64954	15041-20000-06269	6600 N TOPANGA CANYON BLVD #77	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for T-24 for T.I. Pandora Store. Total area: 767 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64955	15041-10001-23588	302 N AMALFI DR	90402	11	123B129   646	4410023002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM			PC Approved	08/06/2015 12:00:00 AM	ADDRESS	34.03212	-118.51465	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1 INSTALL 6540 KW DC ROOF-MOUNTED SOLR ARRAY ON A SINGLE FAMILY HOUSE. UNGROUNDED NVERTER. (20) MOUDULES: SUNPOWER SPR-E20-327  (1) INVERTER: SMA AMERICA SB6000TL-US-22 240>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64956	19041-20003-43384	10420 N DE SOTO AVE	91311	12	204B109    15	2706015017	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	34.25957	-118.58833	12-19-2019 Changes to an approved set of plan, Changes include PV Modules layout on roof. Plan check only, permit fees covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64957	13041-10000-17408	7965 W MELROSE AVE	90046	5	141B177   536	5527013004	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	ADDRESS	34.08392	-118.36331	permit to be pulled at EPC counter only. PC FOR ENERGY. TI FOR EXISTING RETAIL with emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64958	13041-20000-23346	16626 W GUNTHER ST	91344	12	213B137   164	2610023006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Expired	09/22/2015 12:00:00 AM	ADDRESS	34.28285	-118.49389	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.672 KW. 17 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64959	17041-10001-11704	4324 S LIMA ST	90011	9	114A213   399	5116019014	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2281.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.00495	-118.24613	PC TO REFLECT CHANGES TO APPROVED SET. CHANGES TO REFLECT CHANGES ON SITE. SCOPE OF WORK IS MOVING PV MODULES TO MAINTAIN CLEARANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64960	14041-10000-10230	1422 S ABBOT KINNEY BLVD	90291	11	108B145  1450	4238005039	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	33.99029	-118.46524	PLAN CHECK FOR ENERGY ONLY FOR EXISTING RETAIL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64961	16041-10000-20245	1910 E MARENGO ST	90033	14	132A223    41	5201016001	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Issued	10/06/2016 12:00:00 AM	ADDRESS	34.0575	-118.20989	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR AN 7-ELEVEN STORE. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES, AND TWO NEW SUBPANELS. TOTAL AFFECTED AREA IS 1817 SQ. FT. B#16016-10000-09954	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64962	14041-10000-32856	1001 S VERMONT AVE	90006	10	129B197   250	5078010025	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	34.05236	-118.29185	Energy plan check for a  coffee shop T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64963	13041-10000-00961	12411 W SHELDON ST	91352	6	195B165   204	2629019015	(T)(Q)C1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	04/30/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	34.23261	-118.40328	1ST TENANT. FULL PC FOR POWER AND ENERGY. 7-11. (Existing service and main distribution board, addition of 4 new panels)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64964	13041-10000-03057	719 N YALE ST 1-60	90012	1	133-5A213  25	5407024005	R4-1	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Apartment			02/06/2013 12:00:00 AM	03/28/2013 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.06189	-118.24178	FIRE ALARM SYSTEM FOR APARTMENT COMPLEX. 1 NEW PANEL AND 289 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64965	16041-20000-13065	5203 N LEMONA AVE	91411	4	172-5A147 244	2250020001	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			04/14/2016 12:00:00 AM			Reviewed by Supervisor	05/24/2016 12:00:00 AM	ADDRESS	34.1651	-118.45987	3 STORY 5 UNIT APT OVER GRADE PARKING, TOWN HOME STYLE.  New 800A 120/240V single phase service.  Plan check for power.  Building permit filed under 15010-20000-01687COMPLY WITH DEPARTMENT ORDER effective date11/25/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64966	14041-20000-03630	17631 W VANOWEN ST	91406	6	183B129  1030	2229001017	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.19401	-118.51769	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64967	17041-10000-08164	1027 W D ST Bldg 11	90744	15	030B201   756	7417011900		Harbor				2949.00	Electrical	Electrical	Apartment			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Issued	03/14/2017 12:00:00 AM				NEW FIRE ALARM INSTALLATION WITH (36) DEVICES. SYSTEM INTERCONNECTS TO AN EXISTING REMOTE MAIN FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64968	13041-10000-35436	16601 W RINALDI ST BLDG C	91344	12	213B137   476	2610014008	A1-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	12/19/2016 12:00:00 AM		Issued	12/19/2016 12:00:00 AM	ADDRESS	34.27948	-118.49358	"FULL PLAN CHECK FOR POWER AND ENERGY TO NEW COMMERCIAL BUILDING. CONSTRUCTION OF 3 STORY  BUILDING FOR DORMITORY. THIS IS DESIGNATED AS BUILDING ""C"" ON THE PLAN.PLAN CHECKER PLEASE CHECK THE FEES FOR 3 BUILDING A,B AND C.BUILDING PERMIT: 13010-10000-04216"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64969	14041-20001-35464	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.21585	-118.47965	4.10.2015 - Plan check for modifications to approved set. Change ceiling mounted censors to wall mounted censors.  Change some light fixtures and layout. Check updated Title-24 compliance forms.TI TO AN EXISTIING QUALITY COTROL TESTING CENTER (BAXTER).  ADDING NEW LIGHTING AND CONTROLS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1502.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64970	15041-10000-03744	555 S FLOWER ST Floors 27-28	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	Full plan check for an office T.I  ( 27th & partial 28th floor), total area 17920 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64971	18041-10001-03901	1117-1119 S SAN PEDRO ST	90015	14	124-5A211 207	5145025008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.03486	-118.25269	REVISIONS TO PERMITTE DSET OF PLANS- NEW SBD WHICH WILL BE  RELOCATED, NEW DISTRB  DPB, EMPTY NEW 200A PANELBOARD , NEW CIRCUITS AND KITCHEN EQUIPMENT (((((((PC for power and energy for a TI in a commercial 2 story, change of use warehouse to office.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64972	12041-20000-19732	19826 W VENTURA BLVD	91364	3	174B113   406	2164011027	(T)(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1394.00	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.17216	-118.56482	Electrical plan check for build out of tenant shell.  Plan check for power, energy, and emergency lighting.  TENANT IMPROVEMENT IS (E) RETAIL SPACE, NEW FURRED WALLS, NEW T-BAR CEILING, NEW HVAC PLATFORM SUPPORT, NEW STOREFRONT IN (E) OPENING IN CMU WALL. ***SEE COMMENTS***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64973	17041-20000-46487	23631 W COMMUNITY ST	91304	12	192B093   182	2005018016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Issued	01/30/2018 12:00:00 AM	ADDRESS	34.22182	-118.64214	Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.5.2kW ungrounded pv system. (11) 325W pv modules. (1) 5kW Tesla Powerwall 2s.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
64974	18041-10001-46954	1550 N RISING GLEN ROAD	90069	4	147B169   342	5561002035	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.10004	-118.38417	SUPPLEMENTAL FOR EXPEDITED FEES PLAN CHECK FOR 4.6 PV SYSTEM WITH ENERGY STORAGE SYSTEM CONSISTING OF 1 CENTRAL INVERTER(4.6-TL-US-SZ) WITH 15 MODULES(SC- SERIES MODULES) USING RAPID SHUTDOWN DEVICES AND 1 ENERGY STORAGE SYSTEM(14KHW) TESLA POWER WALL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64975	18041-10000-45361	11837 W MAYFIELD AVE 1-7	90049	11	129B145   510	4265015252	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	09/16/2020 12:00:00 AM	ADDRESS	34.0499	-118.46609	NEW FIRE ALARM SYSTEM ION A NEW 29 UNIT APARTMENT BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
64976	15041-20000-37902	7341 N GREENBUSH AVE	91605	2	186B157   484	2328026051	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	08/11/2016 12:00:00 AM	ADDRESS	34.20357	-118.42644	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (PRODUCTION STUDIO). SCOPE INCLUDES A CHANGE OF USE FROM A MANUFACTURING SPACE TO AN OFFICE/PRODUCTION SPACE AND NEW LIGHTING. TOTAL AREA IS 10,075 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64977	18041-10000-08779	3465 W 6TH ST	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.06373	-118.29761	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN AN EXISTING SHOPPING CENTER RESTAURANT. TOTAL SQ. FT. 2270.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64978	16041-10000-34624	1609 W 21ST ST	90732	15	012B193  1143	7562015013	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	33.7256	-118.31197	pc for pv system using central inverter 5kw ac. using 16 modules with power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64979	17041-10000-16631	2490 S WESTERN AVE	90732	15	009B193   167	7460004003	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2973.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.72316	-118.31226	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 11500 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64980	14041-20001-34986	7123 W SUNSET BLVD	90046	4	147B181   636	5548011400	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.09815	-118.34512	Change to approve set of plan. ((TI pizza place energy plan check)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64981	13041-20002-27469	17521 W RAYEN ST	91325	12	195B129   196	2768026011	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	34.23233	-118.51668	expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64982	15041-20000-31832	20830 W COHASSET ST	91306	3	186B109   542	2113026013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.206	-118.58753	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 7 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64983	19041-20001-39856	252 S TAVISTOCK AVE	90049	5	138B145   579	4366019029	R1-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.07124	-118.45961	$0 PLAN CHECK FEE AND PERMIT FEE DUE TO SB1222 AND AB1444PLAN CHECKER ERROR.ADDITION OF A 13.5 KWH BATTERY TO THE PERMIT, PLAN CHECKED ALREADY ON MASTER PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64984	10041-10001-08139	1417 N BRONSON AVE	90028	13	147A191   135	5545015012	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			08/09/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.09618	-118.31811	Revised approved set of plans by including 3 ea rooms /panels/circuits that were omitted from the original approval	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64985	18041-30000-17350	2111 N GRIFFIN AVE	90031	1	136-5A223  28	5204018006	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.06975	-118.21183	Plan check for a fire alarm system with 28-devices and 1-fire alarm control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64986	14041-10000-23300	11500 W DONA DOLORES PL	91604	2	159B169   508	2381011011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.13106	-118.38379	Installation of roof mounted solar system.  System size = 6 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64987	18041-20001-00571	20701 W CLARK ST	91367	3	174B109   675	2151031047	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			PC Approved	01/14/2018 12:00:00 AM	ADDRESS	34.16905	-118.58295	Expedited plan check fee.  PV1.  Install 14.04 kW roof mounted grid tied PV system.  (39) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64988	10041-10000-08868	4425 S CENTRAL AVE Sections-A & B	90011	9	112-5A209 121	5108028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	07/08/2011 12:00:00 AM	ADDRESS	34.00306	-118.25677	remodel the interior of a family health center; work is divided into two phases- phase 1 is referred to Section A and Section B  and has to do with renovations in the corridors, offices, and support area. Phase 2 renovation is reviewed under a separate application. plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64989	19041-30000-11317	2029 S CENTURY PARK EAST Basement-17	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is an existing suite in the D-level basement of a commercial building. Project scope is a tenant improvement. Total lighting area = 2,145 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64990	13041-20000-03374	11352 N RUGGIERO AVE	91342	2	210B173    29	2529020012	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.27603	-118.36669	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64991	18041-30000-22814	350 S MAIN ST	90291	11	109-5A143  98	4286004006	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Info Complete	06/20/2018 12:00:00 AM	ADDRESS	33.99499	-118.47656	PLNA CHECK FOR T24 ONLY, TENANT IMPROVEMENT TO BREAK AREA IN (E) CONCIERGE AREA, TOTAL AREA: 344 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64992	10041-10004-20309	5200 W WILSHIRE BLVD	90036		132B181    30	5507024010	[T][Q]C4-2D-CDO		Wilshire	Greater Wilshire			Electrical	Electrical	Apartment			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.06194	-118.3435	PLAN CHK FOR FIELD CHANGESOF APPROVED SET OF PLANS-installation of diesel fire pump in accordance with NFPA 20 for the pump and its controller. this is not a high buildingNEW MIXED USE APT (478 UNITS) 6 stories	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64993	15041-10000-05654	6455 W SANTA MONICA BLVD	90038	13	144B185   631	5533009032	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.09087	-118.3306	PC FOR POWER AND ENERGY. TENANT IMPROVEMENT AND  CHANGE OF USE FROM POST OFFICE SORTING STATION TO VETINARY CLINIC. TOTAL AREA  8950 SQ FT.BUILDING APP # 15016-10000-00422.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64994	17041-20001-27674	933 N LA BREA AVE 2nd fl.	90038	5	144B181   679	5531016022	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.08811	-118.34432	09/22/2017 Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is tenant improvement. Total lighting area = 3,904 sq. ft.*****Previous Work Description*****INSTALLING (18) PLUGS OFF OF (E) CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64995	12041-10000-14784	3880 N MISSION ROAD	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			06/26/2012 12:00:00 AM			Reviewed by Supervisor	08/23/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	INSTALLATION OF AA CONVEYOR SYSTEM  IN A WAREHOUSE FOR MOVING PACKAGES TO A SHIPPING AREA FOR DELIVERY-PART OF AN E-COMMERCE FACILITY FORA RETAIL COMPANYNOTE THAT CONVEYOR IS IN BLDG F WHICH SHARES A ROOF WITH A BLDG G WHERE THE EXISTING MAIN SWBD IS LOCATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64996	13041-10000-23773	14502 W VESTA CT	91402	6	198B149   640	2644030220	(T)(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.24187	-118.44826	PV1; INSTALLING ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING WITH MAIN PANEL IN A TWO-STORY HOME. TRANSFORMERLESS WITH POWER OPTIMIZERS. SYSTEM SIZE 4.41 KW.(18) MODULES: TRINA SOLAR #TSM-245PC05/PA05.18(1) INVERTER: SOLAREDGE # SE3800A-US(18) OPTIMIZERS: SOLAREDGE OP250-LV	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
64997	18041-20000-48763	11301 W PICO BLVD	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/26/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	ADDRESS	34.03517	-118.43924	plan check for power new exit signs only in an exisitng commercial building.this is plan check only permit fees paid under application 18041-90000-26767	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
64998	19041-20000-18626	1748 N GARFIELD PL	90028	13	148-5A193  38	5544005010	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			05/17/2019 12:00:00 AM	03/23/2021 12:00:00 AM		Permit Finaled	10/27/2022 12:00:00 AM				800A 240/120V 3p-4w service, distribution, power and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
64999	14041-10000-35102	11660 W TUXFORD ST	91352	6	192B169   392	2632023060	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.22347	-118.38618	Title 24 plan check only.  Total area = 69,512 sq. ft.Remove HID light fixture and replace with new LED fixtures.Plan check covers buildings #1, #2, and #3This permit covers only building #1 (warehouse/storage)Building #2 (body shop) permit #14041-10000-35106Building #3 (repair area) permit #14041-10000-35109	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65000	19041-10000-49281	1801 S CENTURY PARK WEST 5TH FLOOR	90067	5	132B157   448	4319009050	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Issued	01/17/2020 12:00:00 AM	ADDRESS	34.05869	-118.42125	TITLE 24 PLAN CHECK FOR AN OFFICE BUILDING ON THE 5TH FLOOR .  TOTAL EFFECTIVE AREA: 6,614. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65001	12041-10000-13105	2915 W LOS FELIZ BLVD	90039	13	157-5A207 373	5594006021	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	ADDRESS	34.12679	-118.26282	T-24 lighting plan check for new Chase Bank.  Interior and exterior lighting.  Total load is 329A  and occupancy load is less than 99, per applicant.  Applicant is referred to test lab for LED light fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65002	15041-20000-14377	5428 S CRENSHAW BLVD	90043	8	108B185   458	5006008008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.99224	-118.33045	PC FOR PV SYSTEM. 1.5KW AC USING SINGLE TRANSFORMERLESS INVERTER. THIS SYSTEM CONNECTS TO TENANT AT 5428 CRENSHAW. THIS IS PROJECT 2/5. ALL SYSTEMS CONNECT TO SINGLE 400A SINGLE PHASE SERVICE. ZONING AND CRA HAVE BEEN CLEARED UNDER PROJECT 1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65003	10041-20000-02210	2850 E OLYMPIC BLVD	90023	14	120A221   123	5170026010	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.02252	-118.21622	REMODEL FIRE DAMAGE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65004	13041-10002-31123	21840 W VENTURA BLVD	91364	3	171B105    30	2168026080	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			12/31/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.16823	-118.60343	TITLE 24 PART 6 ENERGY LIGHTING FOR 3286 SQ FT 'GOODWILL' STORE. DESIGN-BUILD PLAN. SCOPE OF WORK < 400A. EMERGENCY LIGHTING TO BE INCLUDED IN SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65005	17041-20001-40197	4617 N LARKWOOD AVE	91364	3	168B097   572	2074002017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM			PC Approved	11/14/2017 12:00:00 AM	ADDRESS	34.15516	-118.62822	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.11.4kW ungrounded system. (39) 325W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65006	19041-20000-25384	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.27455	-118.56289	Plan check for PV roof mounted system, PV syste size: 270.9KW DC, 200KW AC with 774 PV Modules and 2 inverters(100KW)Fees $0.00 due to California Senate Bill 1222 and AB 1414Note: 2 Structure  under same address. This is Administrative Building. There 2 Building permit number: 19016-20000-20082, 19041-2000-25384	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65007	11041-10000-26742	238 N LARCHMONT BLVD	90004	4	138B189   501	5515025002	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	34.07578	-118.32344	TI in an existing beauty salom, changing lighting, and adding recptacles.  No suite number.  PLAN CHECK ONLY for Energy, with Emergency lighting. Permit for new circuits & lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65008	16041-20000-35266	13031 W JEFFERSON BLVD	90066	8	102B157    51	4211008028	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	33.97451	-118.42531	New optional generator to a single story commercial building.  Reconnect existing optional loads to new generator.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65009	15041-10000-35928	6767 W SUNSET BLVD phase II-1ST FL	90028	13	147A185    57	5547020041	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.09814	-118.33821	ALTERATIONS IN CLASSROOMS-NEW LUMINIRES AND CONTROLS AND DIMMER SWITCHES AND NEW CIRCUITS  ON THE FIRST FLOORPLAN CHK IS OR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65010	15041-10000-19482	1515 N VERMONT AVE	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Issued	10/28/2015 12:00:00 AM	ADDRESS	34.09867	-118.29207	TI TO AN EXISTING HIGHRISE MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.  SCOPE OF WORK TO BE PERFORMED IN THE 6TH FLOOR.  TOTAL SQUARE FOOTAGE 1931.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65011	13041-10000-34500	4611 S ROMA CT	90292	11	102A149    56	4295004064	[Q]RD1.5-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	33.97167	-118.4583	PV1, Install a 2.65 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (10) modules[ SUNIVA # OPT265-60-4-1B)] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65012	15041-10000-39158	11987 N SHOSHONE AVE	91344	12	216B129   185	2601028034	RA-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.28919	-118.51758	PV1INSTALL ROOF MOUNTE PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(20) SOLAR WORLD SW280(20) ENPHASE MICROINVERTERS M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65013	15041-20001-33690	9422 N RUFFNER AVE	91343	12	198B137   120	2687015020	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2015 12:00:00 AM			PC Approved	10/09/2015 12:00:00 AM	ADDRESS	34.24233	-118.497	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(28) TRINA SOLAR MODULES TSM-250(28) POWER OPTIMIZERS P300(1) SOLAREDGE SE7600 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65014	15041-10000-18233	1104 E 12TH ST A THRU C	90021	14	123A211   225	5132016033	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.03101	-118.24759	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  BUILDING HAS BEEN SUBDIVIDED INTO THREE TENANT SPACES.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  ADDING NEW LIGHTS NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65015	15041-10001-42292	6600 N TOPANGA CANYON BLVD # 13	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Supplemental PC, Changes to approved set under Delta-7,8,9,10. No new equipment, Permit under 15041-10000-42292<<ALTERATIONS IN RETAIL STOREPLAN CHK IS FOR TITLE 24>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65016	11041-10000-03752	3103 S LA CIENEGA BLVD #B	90016	10	123B173  1531	4205035013	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM			PC Approved	03/08/2011 12:00:00 AM	ADDRESS	34.02996	-118.37335	Ti in an existing office. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65017	15041-20001-17999	18221 W MARILLA ST	91325	12	201B125   248	2764018017	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.24742	-118.53054	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total area = 6.5 kWac.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65018	15041-10001-21382	1234 S ELDEN AVE	90006	1	129B197   932	5076017007	R3-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2015 12:00:00 AM			Verifications in Progress	08/14/2015 12:00:00 AM	ADDRESS	34.04809	-118.28756	EXPEDITE PER APPLICANT REQUEST.PV 1 ROOF MOUNTED SYSTEM. TOTAL SIZE 10.08 KW, 36 PANELS AND 2 INVERTERS. (36) LG280S1C-B3(1) ABB # PVI-5000-OUTD-US (1) ABB # PVI-3.6-OUTD(-S)-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65019	18041-10000-36449	11555 W CANTARA ST	91605	6	192B169   514	2311001012	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1219.00	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.21938	-118.38398	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65020	17041-10000-39196	1421 E 15TH ST	90021	14	121-5A213 350	5130012012	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	04/06/2021 12:00:00 AM	ADDRESS	34.02522	-118.24456	PC for power and energy for two story office/warehouse building. Installing new 600A service and service panel, two subpanels, equipment, receptacles and lights. Building 14010-10000-02791	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65021	14041-10001-24451	2740 W WAWONA PL	90065	14	160-5A219 168	5683020014	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.13401	-118.22473	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(24) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65022	17041-10000-41763	6301 W SANTA MONICA BLVD	90038	13	144B185   696	5533007032	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.09088	-118.32695	Remove Outdoor HID fixtures and replace with new LED fixtures. T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65023	15041-10000-37840	462 E COMMERCIAL ST SERVICE-BLDG	90012	14	130-5A215  46	5173001905	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.05309	-118.23584	ONE-STORY SERVICE BUILDINGSEE 15010-10000-01117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65024	19041-10000-03048	16927 W MOONCREST DR	91436	5	165B133   387	2292004003	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.14706	-118.50223	PC FOR ROOFTOP PV SYSTEM 10.6KW AC. SCOPE OF WORK INCLUDES (44) 325W PV MODULES WITH P400 OPTIMIZERS, (1) 3KW AC INVERTER, AND (1) 7.6KW AC INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65025	12041-10000-23115	1630 W 186TH ST	90248	15	060B193   248	6108002022	P-1VL, [Q]MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	01/24/2013 12:00:00 AM	ADDRESS	33.86187	-118.30705	TI in the TOYOTA Tech. Center. Add new panels, equipments, and ckts. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65026	11041-20000-16021	11150 W OLYMPIC BLVD #600	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	08/01/2011 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.03956	-118.43857	PLAN CHECK T24 ENERGY/EMERGENCY TENANT IMPROVEMENT ON 6TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65027	17041-10000-24148	5343 W IMPERIAL HWY	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			Corrections Issued	07/18/2017 12:00:00 AM	ADDRESS	33.93128	-118.37337	PC for T24 for new lights inside walk in cooler rooms. Total sqft 2635 sqft. Building #17016-10000-18837.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65028	12041-20000-20282	6430 N BELLINGHAM AVE	91606	2	180B165   643	2322006041	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1238.00	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.18755	-118.3986	Change of use from retail to dental office.  Plan check for Power and Energy.  No unit number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65029	18041-10001-48770	18953 W HARNETT ST	91326	12	207B121   705	2728016009	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.26129	-118.54666	Expedite per applicanet requestPLAN CHECK FOR ROOFTOP MOUNTED 11.66 kw DC and 7.60KW AC PV SYSTEM WITH (37) MODULES , (1) AC INVERTER WITH 7.6 KW(SE7600H-US),  (1) POWER OPTIMIZER P320.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65030	15041-10001-02341	8161 W BEVERLY BLVD	90048	5	138B173   375	5514008045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			PC Approved	04/14/2016 12:00:00 AM	ADDRESS	34.07624	-118.36735	04/14/16Changes to an approved set of plans. All change clouded under delta 1. Changes include adding an auto-dialer(Potter PFC-6006) to the methane gas detection system. NOTE: Permit pulled PCIS#15041-10000-02341((((Plan check for methane gas mitigation detecting system with (1) communication panel, (1) control panel, & (21) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65031	12041-20002-14170	4959 W SANTA MONICA BLVD	90029	13	144B197   728	5540009008	C2-1D	Central	Hollywood	East Hollywood		1912.04	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.09098	-118.29784	((CHANGES MADE TO APPROVED SET OF PLANS. T24 AND LOAD CHANGES. LOAD DECREASED BY 78 AMPS. ))Change of use from retail to restaurant.  New 600A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65032	16041-10000-09960	202 E 76TH PL	90003	9	099B205   199	6022014017	R1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	33.97036	-118.27169	PV1, rooftop solar installation 7.6 kW AC.     (34) #KD255GX-LFB3      (1) PRIMO 7.6        Standard  plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65033	14041-10000-10507	380 WORLD WAY TBIT 4THFL-T19	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED (E) RETAIL SPACE ADDING SOFFIT ONLY.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65034	15041-10000-15513	822 N KENTER AVE	90049	11	138B137   240	4494022034	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2015 12:00:00 AM			PC Info Complete	11/13/2015 12:00:00 AM	ADDRESS	34.07362	-118.48947	NEW LARGE 2-STORIES SFD WITH BASEMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65035	12041-20000-18156	1635 N CAHUENGA BLVD	90028	13	148-5A187 221	5546007028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.10071	-118.32971	energy bplan check parking and elevator lobby	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65036	19041-20000-13116	5900 W CENTER DR 1-327	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	33.97559	-118.38853	$0 permit and plan check fee due to SB1222 and AB1414Plan check for a PV2 roof-mounted PV system. System size is 136.88 KW DC/125.07 KW AC-CEC/133.2 KW AC. Scope of work includes (4) SE33.3KUS inverters, (375) astrohalo pv modules, (1) 225KVA transformer, (188) P730 optimizers, and a 200A load centers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65037	16041-10000-34943	11111 W SANTA MONICA BLVD 10th FL-COR & REST	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.04771	-118.44481	Pc for title 24 in eleveator lobby and restrooms in high rise.New receptacles and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65038	16041-20000-37694	4426 W WAWONA ST	90065	14	160-5A219 305	5683019031	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/05/2016 12:00:00 AM	PIN	34.13235831	-118.22698797	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.32 KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65039	18041-10000-07651	777 E 10TH ST #106	90021	14	124-5A211 244	5132002041	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.03437	-118.24974	PC for T24 only for change of use from retail to restuarant. Installing new lights, receptacles and equipment. Total 461sqft. B#18016-10000-05556	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65040	15041-10000-11938	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	05/05/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	33.92817449	-118.43220714	ONE FOR ONE REPLACEMENT OF EXISTING FIRE ALARM DEVICES. 512 FIRE ALARM DEVICES, FIRE ALARM PANEL TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65041	16041-10000-39101	814 S COLUMBIA AVE	90017	1	130-5A205 333	5143001006	C2-2	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM			Corrections Issued	11/07/2016 12:00:00 AM	ADDRESS	34.05018	-118.27002	PV2 roof mounted solar system installation to a commerical building. Instaling a new 3.6 Kw system, (15) Solar moduels with its respective optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65042	18041-20000-34393	935 E 59TH ST	90001	9	105B209     4	6007003011	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Closed	01/26/2024 12:00:00 AM	ADDRESS	33.98736	-118.25812	Plan check for power and energy. Project scope is a change of use from warehouse to indoor nursery. Work includes a complete tenant improvement and a total lighting area of 37,495 sq. ft.Note: Building application has been generated under 18016-20000-29130	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65043	16041-20000-35940	5200 N LANKERSHIM BLVD 5TH FLOOR	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 5TH FLOOR.  574 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65044	19041-10000-32524	2500 S NAVY WAY	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM			PC Info Complete	10/04/2019 12:00:00 AM	ADDRESS	33.73363	-118.2408	POWER PLAN CHECK FOR AN OFF ROAD ELECTRIC VEHICLE INDUCTION CHARGING STATION AT THE PORT OF LA. SYSTEM CONNECTED TO AN EXISTING 2000A SWITCHGEAR.	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
65045	13041-20000-09337	5142 N TUJUNGA AVE	91601	4	171B173   726	2353002030	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.16425	-118.37883	Plan check for energy and emergency lighting. bathrooms for low-rise commercial. YMCA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65046	17041-20000-38463	12732 N PASEO DEL SERENO	91342	7	222B149  1170	2506031050	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.30187	-118.45229	Plan check for solar pv system w/roof-mounted array on SFD.Total system size: 3.22kW ungrounded.(14) EnPhase IQ6 microinverters.(14) 285W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65047	17041-20000-10485	5410 W WILSHIRE BLVD	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Info Complete	05/01/2017 12:00:00 AM	ADDRESS	34.06204	-118.34668	New emergency life safety 150 kW diesel generator with associated distribution for an (E) commercial highrise building.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65048	13041-10000-29580	1563 W 218TH ST	90501	15	048B193    57	7346002038	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Expired	02/11/2016 12:00:00 AM	ADDRESS	33.83038	-118.30596	PV1.  Install 10.78 kW DC roof-mounted solar array, interconnect with main service panel.   Inverter: Fronius IG Plus V 7.5.  44 modules: Yingli Yl245P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65049	12041-10000-31137	11900-11914 W COURTLEIGH DR	90066	11	111B161  1000	4233019020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	33.99718	-118.41875	FIRE ALARM SYSTEM FOR NEW BUILDING. 117 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65050	18041-10000-19288	4570 W COLORADO BLVD	90039	13	162B205   118	5593018015	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.14078	-118.27277	PC FOR TI WORK IN EXISTING  WAREHOUSE BLDG ON THE FIRST AND SECOND FLOOR FOR TITLE 24 ENRGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL EFFECTED AREA 2327SQ.FTB#18016-10000-16272	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65051	14041-20001-16216	18901 W BAHAMA ST PV1	91324	12	195B121   119	2784023019	RS-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM			Corrections Issued	07/09/2014 12:00:00 AM	ADDRESS	34.23337	-118.54514	Modification of previously issued express permit for roof mounted solar array on SFD. System upsized from (17) to (22) Trina Solar #TSM-255PA05.18 modules, and inverter upsized from a 3.6kW transformerless inverter to (1) PowerOne Aurora PVI-5000-OUTD-US-Z-A transformerless inverter. New system size: 5kW.[[[INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 4.335 KW]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65052	12041-10000-15846	14401 W VENTURA BLVD	91423	5	166-5A151 296	2265014017	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			07/09/2012 12:00:00 AM	08/20/2012 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.15069	-118.44613	Plan check new roof mounted 128.8KW photovoltaic system for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65053	13041-10001-33002	23445 W STYLES ST	91367	3	177B093   192	2035010028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.18405	-118.63868	Expedited RSES plan check per applicant request.PV1, Install 7.5 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(2)Transformerless inverter(s): SolarEdge SE3800A-US and SolarEdge SE3000A-US. (30) modules: Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65054	16041-20000-13351	15821 W VENTURA BLVD Suite 515	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for energy only. TI to existing office on 5th floor of high rise office building. New lighting (incl. emergency) and receptacles. 1,257sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65055	19041-10000-39430	7150 N TAMPA AVE	91335	3	183B117    99	2129001009	R1-1-RIO, RD2-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			Reviewed by Supervisor	11/04/2019 12:00:00 AM	ADDRESS	34.20068	-118.55332	NEW FIRE ALARM FOR THE LA JEWISH HOME RETIREMENT HOMES. SCOPE INCLUDES TWO NEW FIRE ALARM PANELS, 8 POWER SUPPLIES, 6 ANNUNCIATORS, 1 GRAPHICAL ANNUNCIATOR PANELS AND 1778 DEVICES. (NUMBER OF DIVICES GIVEN BY THE ENGINEER) PLANS ARE NOT LEGIBLE. (FEE ESTIMATE ONLY)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65056	10041-10000-21153	1930 W WILSHIRE BLVD 14th floor	90057	1	132A203    41	5142002019	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Expired	12/31/2012 12:00:00 AM	ADDRESS	34.05713	-118.27464	Alterations on the 14th floor of a commercial building. the floor will include doctor's office , and other general office functions- there will be no medical examination are treatment in these offices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65057	14041-10000-31366	15040 W CALVERT ST	91411	6	177B145   405	2242024041	M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.18099	-118.46097	Full plan check for an auto body shop (hazardous arear) and office T.I. ; most existing load including circuit breakers, feeders and panel boards will be replaced from (2) services switchboard (single phase and 3-phase).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65058	17041-10000-03691	3774 S WESTERN AVE	90018	8	117B193   610	5036008035	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.01805	-118.30873	New foodmart store at existing gas station . NEW SERVICE RATED AT 600 FOR 120/208 V 3PH 4W. ALL NEW EQUIPMENT AS SHOWN ON SINGLE LINE. AREA IS 2219 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65059	18041-10001-22367	1127 W WILSHIRE BLVD 200	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM			PC Approved	10/19/2018 12:00:00 AM	ADDRESS	34.05287	-118.26415	PLAN CHECK FOR RECIRCUITING OF EMERGENCY FIXTURES TO BUILDING'S EMERGENCY POWER. NOTED UNDER DELTA 1. PLAN CHECK ONLY.____________________________________________PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT TO EXISTING MEDICAL OFFICE BUILDING (RADIOLOGY). SCOPE INCLUDES USING ALL EXSTING DISTRIBUTION EQUPIMENT WITH ALL NEW CONNECTED LOAD, TOTAL AFFECTED AREA = 1174 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65060	13041-10000-15311	133 W AVENUE 45	90065	1	147A223   187	5467009001	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1851.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Info Complete	06/11/2013 12:00:00 AM	ADDRESS	34.09657	-118.20819	Title 24 only, reatil space, existing time control	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65061	19041-10000-13003	1250 W COURT ST 1-54	90026	1	135A209   290	5160019016	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Apartment			04/10/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	05/10/2021 12:00:00 AM	ADDRESS	34.06343	-118.25574	FULL PLAN CHECK FOR A NEW 6-STORY 54-UNIT APARTMENT BUILDING WITH 2 LEVELS OF PARKING GARAGE AND POOL DECK. SCOPE INCLUDES NEW 1600A SERVICE. TOTAL AFFECTED AREA IS 25000 SQ.FT. The address on the plans is 1246 W Court St. LA but the building permit is under 1250 W Court St. LAB# 17010-10000-02581Fire Alarm Varience is Submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65062	15041-10000-30849	13690 W VAUGHN ST	91331	7	210B157    62	2523004009	M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	PIN	34.27518901	-118.43036352	T24 ONLY. REPLACING EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 14916 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65063	16041-20001-09982	22320 W KITTRIDGE ST	91303	3	180B101   262	2139010009	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.19134	-118.61302	Expedited per applicant request.Plan check for the addition of a 3 kWac PV system to an existing 5 kWac system for a total system size of 8 kWac. System addition consists of (1) inverter, (12) modules, and (1) load center. MCB is being derated.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65064	16041-10001-27658	405 S MATEO ST	90013	14	127-5A217  62	5163018006	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	08/01/2018 12:00:00 AM	ADDRESS	34.04184	-118.23305	Changes to approved set (partial single line diagram is revised, T24 revised due to architectural change), all changes are clouded.<<PC FOR POWER AND ENERGY. CORE&SHELL RENOVATION OF EXISTING BLDGS, NO TENANT IMPROVEMENT IS INCLUDED AS PART OF SCOPE. SERVICE 4000A, 480/277 3 PHASE AND 4W. TOTAL AREA 5919 SQ FT.B#  16016-10000-17710>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65065	15041-20001-00870	4425 N CANOGA AVE	91364	3	166-5A107 173	2190014022	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	ADDRESS	34.14993	-118.5957	Expedite per customer request.PV1. Install roof mounted PV system sized 9.84 kW. 400A split bus. Interconnected with main service pannel.(41) Sunmodule SW 285 Mono modules(41) Enphase M250 microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65066	18041-20000-45445	812 N EL ORO LANE	90272	11	129B121   293	4419012024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.05077	-118.54807	Plan check for PV roof mounted system and energy storage system, PV system size: 12.25kW DC, 10.6kW AC with 2 inverters(7.6kW and 3.0kW) and 35 PV modules LG Chem battery 9.8kWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65067	15041-20000-18439	10925 N OWENSMOUTH AVE	91311	12	210B105   210	2722004034	RE40-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.2686	-118.60231	PV1 SFD. TOTAL SYSTEM SIZE 11.4KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS. TOTAL OF 38 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65068	16041-10000-35952	345 N WESTMORELAND AVE	90004	13	138B197   140	5501002002	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Apartment			10/11/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.07753	-118.28811	Full plan check for a new 6 story residential apartment building (homeless shelter). Building includes 65 units and commercial use on ground level. All panels in all units are similar (typical) except for house panels. Scope includes a new  2500 Amps 208Y/120v 3phase 4wire distribution board fed from an existing service/distribution board. Existing equipment noted on plans. Total sqft = 18050. B#16010-10000-01432	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65069	16041-10000-42322	9633 N BADEN AVE	91311	12	201B097   120	2724011023	(T)RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.2456	-118.61943	PC FOR ENERGY. REPLACE OUTDOOR FIXTURES WITH NEW LED FIXTURES  TOTAL AREA 48090 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65070	12041-10000-22696	333 S HOPE ST	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	Ti in an office for banck of America. EPC is for T24 (19th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65071	17041-10000-23609	20213 W BASSETT ST	91306	3	183B113   653	2135035023	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.19566	-118.57381	roof mountedPC for PV1 sfd total system size 11kw AC using 2 central inverters. total of 33 modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65072	16041-20000-08971	20273 W HAMLIN ST	91306	3	180B113   348	2134018001	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.19085	-118.57516	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (25) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65073	16041-10001-10003	1245 W WILSHIRE BLVD # 635	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. CHANGE TO LOW VOLTAGE CONTROLS INSTEAD OF LINE VOLTAGE. UTILIZING ROOM CONTROLLERS AND LOW VOLTAGE CONNECTION TO ROOM CONTROLLER.<<FULL PC FOR POWER AND ENERGY. TI TO AN (E) MEDICAL OFFICE BUILDING FOR SUITE 635. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR EXAM ROOMS (GENERAL CARE/ NON INVASIVE PROCEDURES) AND OFFICE SPACE. TOTAL AFFECTED AREA IS 1501 SQ. FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65074	18041-10000-24791	690 W KNOX ST	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.85406	-118.28817	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65075	16041-10000-09985	5077 N LANKERSHIM BLVD suite C	91601	2	171B173   943	2353010014	C4-1-CA, R4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.1626	-118.37361	TI PROJECT IN EXISTING SHELL  CHANGE OF USE FROM RETAIL TO RESTAURANT 30'X70' IRREGULAR. TI ON FIRST FLOOR-firehouse subs	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65076	13041-10000-30369	1810 N STANLEY AVE	90046	4	150B177   536	5551011017	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.10384	-118.35605	PV1, Instal 6.75 kW DC roof-mounted solar array for a house, interconnected  with the main service panel. NO batteries. Microinverter.25 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65077	13041-10000-35321	521 W 182ND ST	90248	15	063B201    94	7339007019	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/26/2013 12:00:00 AM	ADDRESS	33.87043	-118.28237	INSTALLATION OF NEW (1) 499 GALLON PROPANE STORAGE TANK IN CLASSIFIED AREA. AREA IS CLASS 1, DIV 1. 230Vac, 20A CIRCUIT , WITH 1-HP, SINGLE PHASE. SEALS-OFF WILL BE PROVIDED, EMERGENCY SHUT-DOWN STATIONS EXPLOSION PROOF, OPERATION SWITCH EXPLOSION PROOF. RIDIG CONDUIT ABOVE GRND RUNS FROM MOTOR TO EMERGENCY SHUT-DOWN STATION. GENERAL CONTRACTOR DESIGN-BUILD; TRAITS INCLUDES: CARPENTRY + CONCRETE. PLAN CHECKED PER SUPERVISOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65078	16041-20000-00337	1000 W WILSHIRE BLVD suite 400	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.05085	-118.26078	TI to existing high rise office building (4th floor). Adding new lighting including emergency. Total sqft. 12,212.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65079	11041-10000-05520	780 N SWARTHMORE AVE	90272	11	126B125   117	4412009031	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			03/21/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	07/12/2014 12:00:00 AM	ADDRESS	34.04464	-118.52629	Ti in an existing school. EPC is for power & T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65080	11041-20000-25821	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM			PC Approved	12/05/2011 12:00:00 AM	ADDRESS	34.08363	-118.32191	Existing kitchen area within the Paramount Studios.  Upgrading/ replacing the light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65081	13041-10001-33015	2834 S POTOMAC AVE	90016	10	123B181  1531	5057007016	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/10/2013 12:00:00 AM	ADDRESS	34.03005	-118.34379	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 3.5KW. TRANSFORMERLESS UNGROUNDED SYSTEM.(14) TRINA SOLAR # TSM-250(14) SOLAREDGE POWER OPTOMIZERS OP250(1) SOLAREDGE # SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65082	19041-20000-52723	7939 N CANOGA AVE	91304	3	189B105   191	2110005014	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	07/17/2020 12:00:00 AM		Permit Finaled	08/07/2021 12:00:00 AM	ADDRESS	34.21451	-118.5977	Full plan check for a HYDROPONICS CULTIVATION & MANUFACTURING with new distribution, and equipment. Total lighting area cover 5,533-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65083	18041-10000-44526	730 N WATSON AVE	90744	15	030B213   144	7424023034	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.78036	-118.24662	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65084	15041-10000-14954	1547 N TOWER GROVE DR	90210	5	147B157   241	4356015022	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM			Reviewed by Supervisor	06/04/2015 12:00:00 AM	ADDRESS	34.09849	-118.42597	PV1 INSTALL 11.96 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (46) MODULES: KYOCERA  KU2606XPA(3) INVERTER: PVI-3.6-PUTD-S-US-Z-A & 3.0-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65085	10041-10000-15375	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM			PC Approved	08/06/2010 12:00:00 AM	ADDRESS	34.09783	-118.36466	T.I. to existing building.  Install outdoor lighting at the entrance.  Plan check for energy only.  Permit is under 10041-90000-13183.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65086	18041-10000-16849	9650 N RESEDA BLVD	91324	12	201B125   307	2764006032	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.24607	-118.53588	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65087	13041-10001-02351	11725 N HUNNEWELL AVE	91342	7	213B165   172	2531032029	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1042.04	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.28326	-118.4002	MODIFICATION TO APPROVED SET OF PLANS. ADDITION OF TWO MODULES AND MAIN PANEL UPGRADE.  SYSTEMS SIZE INCREASED TO 5.184 KW. MODULES CHANGED FROM REC 245 TO REC 230PE-US.  *****************************************************************************PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY TWO STORY DWELLING. TOTAL SYSTEM SIZE OF 4.75KW. USING 22 MODULES. ENPHASE M215-60-2LL-S22 MICROINVERTER. SOLAR PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65088	17041-20000-21240	12021 W VENTURA BLVD	91604	2	162B165    97	2368002035	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1438.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM			PC Approved	06/23/2017 12:00:00 AM	ADDRESS	34.14383	-118.39417	CHANGE OF USE FROM RETAIL STORE TO RESTUARANT.  PLAN CHECK FOR ENERGY CONSERVATION REQUIREMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65089	19041-10000-42434	4147 W 62ND ST	90043	8	105B181   861	4003015017	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	33.98363	-118.34768	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) WITH 13 MODULES USING P400 OPTIMIZERS WITH ESS(TESLA POWERWALL) CONNECTED TO EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65090	15041-20001-07309	23254 W FRIAR ST	91367	3	177B093    44	2035020041	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	34.18529	-118.63355	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  40 modules (6 strings) connected to 2 inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65091	17041-20001-15066	2949 E 3RD ST	90033	14	126A225   301	5179004045	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM			PC Approved	05/25/2017 12:00:00 AM	ADDRESS	34.03799	-118.20329	expeditepv2install roof mounted pv system sized 1.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65092	19041-10000-08049	15429 W LA MAIDA ST	91403	5	168B145   252	2261036016	R1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.15862	-118.47032	NOTE: FEES ARE $0 DUE TO AB 1414.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 13.5KWdc / 10.0KWac.(45)MODULES-LONGI LR(45)OPTIMIZERS-SOLAREDGE SE10000-US INVERTER(1)INVERTER-SOLAREDGE SE10000H-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65093	17041-30000-19337	1603 S LA CIENEGA BLVD	90035	5	129B173   885	4303028032	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.04895	-118.37642	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is an addition to an existing warehouse. Total lighting area = 3,053 sq. ft.Note: Building application has been generated under 17014-30000-02711	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65094	17041-20000-45980	9601 N MASON AVE	91311	12	201B109   284	2748003080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Info Complete	01/11/2018 12:00:00 AM	ADDRESS	34.24457	-118.57997	PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT FOR STORAGE WAREHOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65095	14041-20000-14992	15701 W TUBA ST	91343	12	204B141   425	2661016009	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Expired	08/19/2016 12:00:00 AM	ADDRESS	34.25655	-118.4742	New roof mounted PV system with Optimizers and transformerless inverters.  Total system size 7.4KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65096	17041-20000-41458	1333 S BEVERLY GREEN DR 1-4	90035	5	129B165   130	4330004010	[Q]RD2-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			11/15/2017 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.05319	-118.40537	Plan check for power and energy. Project site is a new 2-story, 4-unit apartment building. Work includes a new 600-amp service and a total lighting area of 6,336 sq. ft.Note: Building application has been generated under 17010-30000-00174	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65097	09041-10002-09723	458 S HARTFORD AVE	90017	1	132A207   113	5153023012	CW, CW  R5(CW)-U/6	Central	Westlake		YES	2091.01	Electrical	Electrical	Apartment			07/29/2010 12:00:00 AM	09/10/2010 12:00:00 AM		Permit Finaled	11/02/2010 12:00:00 AM	ADDRESS	34.05693	-118.26342	Change to the priviously approved plan. Add lights and new circuits. Plan check for changes. (((((((((((((((PLAN CHECK POWER AND ENERGY.  NEW ELECTRICAL SYSTEMS 66 UNIT  (4  STORIES OVER 1 STORY PARKING GARAGE.  (APPLICATION 1 OF 2).  VARIANCE TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.)))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65098	12041-10000-27996	7149 WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	11/21/2012 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	33.94334	-118.41857	FIRE ALARM. ADD DEVICES (Monitoring Modules) TO APPROVED plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65099	16041-10001-31215	401 W WESTMONT DR	90731	15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	33.76342	-118.2899	EXPEDITE PER APPLICANT REQUEST. ((((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3069.52KWdc / KWac.(8296)MODULES-SUNPREME MAXIMA-GXB-370(29)INVERTERS-DELTA ELECTRONICS M90U-122(1)4000A SWITCHBOARD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65100	12041-10000-30996	19230 W CHEYENNE ST	91326	12	207B117   182	2728004034	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.2653	-118.55243	PV1 MICRO INVERTER TWO STORY HOUSE. 17 SOLAR MODULES. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}] ROOF MOUNT STANDARD PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65101	19041-20000-24411	6248 W PRIMROSE AVE	90068	4	151-5A189 238	5586001039	R1-1	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.10956	-118.32486	PV1.  Install 15.18 kW DC / 12.903 kW AC roof mounted grid tied PV system.  (46) modules with (2) 7.6 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65102	18041-10000-29981	6030 S SEABLUFF DR 1-75	90094	11	102B157   327	4211032223	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	33.97298	-118.42231	PLAN CHECK FOR FIRE ALARM SYSTEM FOR 5 STORY APPARTMENT WITH 1 LEVELS OF UNDERGROUND PARKING - SYSTEM SIZE 1 FACP AND 482 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65103	15041-10000-32236	7300 N TOPANGA CANYON BLVD # 10-11	91303	3	186B101   878	2111011050	[Q]C1.5-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.20307	-118.60573	TI  FOR  (E)  YOSHINOYA  RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65104	16041-10000-41209	917 W 17TH ST	90015	1	126A203   172	5135028023	M1-1-HPOZ, R3-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	34.03927	-118.27671	REPLACE HID FIXTURES WITH NEW LED FIXTURES T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65105	18041-10001-09694	2223 W BERKELEY AVE	90026	13	142-5A207 233	5423010013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	05/23/2018 12:00:00 AM	ADDRESS	34.08443	-118.26173	PC FOR CHANGES TO APPROVED SET TO REFLECT CORRECT SERVICE LAYOUT (MSP FROM SINGLE FAMILY TO DUPLEX - 2 GANG).THIS IS PLANCHECK ONLY!NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 17 MODULES (EAGLE PERC60 290w), OPTIMIZERS (SOLAR EDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE5000A-US). SYSTEM SIZE IS 5KWac AND 5.44KWdc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65106	15041-20000-19634	12024 W EMELITA ST	91607	2	174B165   199	2340011009	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.17618	-118.3951	PV1. Install roof mounted PV system sized 3.6 kW. Interconnected with main service panel.(15) Sunny Boy 240 Microinverters(15) Sunmodule SW 285 Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65107	16041-20002-16708	3400-3404 W SUNSET BLVD	90026	13	144A203   344	5427026021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Apartment			06/21/2019 12:00:00 AM			PC Approved	06/21/2019 12:00:00 AM	ADDRESS	34.08744	-118.27608	06-21-2019 Changes to an approved set of plans, Changes include rewiring-circuit in the stairwells from 2 sources with independant system according to ART 700. All changes has been clouded as delta 8 and 9. Changes apply to delta 8 and 9 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65108	18041-20001-47866	15455 W SHERMAN WAY pv3	91406	6	183B145   785	2222025***	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM			Re-Activate Application	05/21/2019 12:00:00 AM	ADDRESS	34.20148	-118.47029	5/20/2019changes to an approved set of plans.  changes to inverter size (3) 14.4KW and change of modules to mission 375W.  total system size 43.4KW AC.  this is plan check only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65109	19041-30001-09205	9820 W EXPOSITION BLVD ev2	90034	5	120B165    54	4313010043	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM			PC Approved	07/23/2019 12:00:00 AM	ADDRESS	34.02867	-118.4016	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1 ONLY. CHANGING SIZE OF FEEDER AND REMOVING AC DISCONNECT. <<<addition of (9) EV chargers to an existing apartment building.  plan check for power.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65110	17041-10000-03796	3867 S EDGEHILL DR	90008	10	117B185   869	5033011044	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.01549	-118.33109	roof mountedPV1 SFD TOTAL SYSTEM SIZE 3.8 KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 12 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65111	13041-20001-08481	18080 W CHATSWORTH ST 1-6	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.26439	-118.52639	supp to original application. changes are for count of lighting fixtures. pc for t24 energy only. clouded CS changesChange to lighting, loads in an existing restaurant space.   Load is less than 400 amps and occupancy load is less than 99 people per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65112	16041-10000-44321	6540 W FOOTHILL BLVD #108	91042	7	201A203   163	2564012037	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1013.00	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	34.24526	-118.2751	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN EXISTING TAKE OUT RESTUARANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 352 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65113	10041-10000-07708	1337 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			Corrections Issued	06/01/2010 12:00:00 AM	ADDRESS	34.05034	-118.22437	INSTALLATION OF A 3.25 KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65114	17041-10000-12198	5407 S NORMANDIE AVE	90037	8	108B193   592	5003017031	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	33.99298	-118.30035	PC for energy only, Outdoor Title-24. Remove HID fixtures and install new LED lights. Area: 13,750 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65115	15041-10001-27730	929 N HOBART BLVD	90029	13	144B193  1312	5535024019	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	34.08714	-118.30524	PV 2 roof mounted solar, 3.975 kW system.(15) modules: KYOCERA # KU2656ZPA(1) inverter: ABB #PVI-3.6-OUTD-S-US-Z-A*NOTE: Building has multiple meters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65116	19041-20000-15377	18335 W RANCHO ST	91356	3	168B125   536	2184058002	A1-1XL	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.1543	-118.53224	PV1.  Install 16.5KW DC/15.2KW AC/15.429KW AC CEC roof mounted grid tied PV system interconnecting with 400A 240/120V 1ph-3w service.  (50) modules with (2) 7.6 kW rated inverters and a 125A pv subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65117	12041-20001-00578	16005 W SHERMAN WAY	91406	6	183B141    86	2206035033	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Approved	07/25/2012 12:00:00 AM	ADDRESS	34.20138	-118.48171	Changes from previously approved plans.  Down size over current rating and reduce the number of service drop conduits.  Plan check for power only.  Existing permit.Note: Previously approved plans submitted for reference only.*****Replace existing 400 ampere single phase and three phase 120/240 volt services with new combined 800 ampere 120/240 three phase 4 wire service.   Reconnect existing three phase feeders.******	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65118	18041-10003-21550	1047 S WINDSOR BLVD	90019	10	132B189  1130	5082019021	R1-1-HPOZ	Central	Wilshire	Olympic Park		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.05437	-118.32621	SUPPLEMENTAL CHANGES TO APPROVED SET CHANGES APPLY TO DELTA (1) ONLY. CHANGES INCLUDE NUMBER OF MODULE TO (17), INVERTER(PV1-5000-OUTD-US), CONDUCTOR SIZE AND OCPD ON LOAD CENTER. MASTER PLAN # 18041-10000-21550	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65119	15041-20000-42469	4600 N VANALDEN AVE	91356	3	168B117   538	2177003001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.15362	-118.55422	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.5KWac/ 8.4KWdc. (30)MODULES-SOLARWORLD 280 MONO BLACK(30)MICROINVERTERS-ENPHASE M250	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65120	17041-20000-12244	11201 N CHRISTY AVE	91342	7	210B177   229	2528028041	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	PIN	34.27254506	-118.35953322	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.4 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65121	15041-10000-01360	200 WORLD WAY TERM 2-DEPT LEV 3	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/15/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 DEPT  LEV 3  SPACE 223PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65122	18041-20000-47866	15455 W SHERMAN WAY pv3	91406	6	183B145   785	2222025***	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	02/12/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.20148	-118.47029	permit fee $0.00 by state senate bill no. 1222Plan check for PV roof mounted system, System size: 46.2kW DC, 23.4kW AC with 140 PV modules and 3 inverters( (2) 14.12kW and (1) 9.0kW) connected to Existing 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65123	13041-20000-24469	4550 W PICO BLVD STE D-305	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.04842	-118.33486	PC FOR POWER AND ENERGY. ALL NEW ELECTRICAL FOR NEW TENANT. NEW SPORTS AUTHORITY. TOTAL AREA 33143 SQ FT. EXISTING 600A SERVICE WITH NEW 600A RATED DISTRIBUTION. LOCATED IN METHANE BUFFER ZONE. UNDERGROUND WORK, PLEASE VERIFY.INVESTIGATION FEE DUE. PERMIT WILL EXPIRE WITHIN 30 DAYS FROM DATE OF ISSUANCE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65124	15041-20001-08091	8931 N MCLENNAN AVE	91343	12	195B133   158	2688026036	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2015 12:00:00 AM			PC Approved	04/01/2015 12:00:00 AM	ADDRESS	34.23301	-118.50092	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65125	18041-10000-44774	19069 W BRAEMORE ROAD	91326	12	216B121    41	2820012011	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.29249	-118.54951	PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 48 MODULES (SOLARIA POWER XT 355R-BD) AND 48  MICROINVERTERS (ENPHASE IQ7-PLUS-72-2-US).  SYSTEM SIZE IS 17.040KWdc and 13.92KWac. SCOPE INCLUDES 200A AC COMBINER BOX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65126	14041-10000-28273	507 S TOWNE AVE	90013	14	127-5A213 369	5147022031	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.04286	-118.2424	T-24 for an office building. total area 210 sq ft. restrooms. Plan check only per inspector request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65127	17041-20000-46555	20653 W CELTIC ST	91311	12	210B109    95	2707033014	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.27108	-118.58384	"""28$ permit fees due to senate bill 1222""pv1install roof mounted pv system sized 10kw interconnected with msp.this system is an addition to an existing pv system."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65128	11041-20000-13377	11845 W OLYMPIC BLVD	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM	06/28/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	PIN	34.03325831	-118.45191172	TI IN AN EXISTING OFFICE. EPC IS FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65129	10041-20000-00331	8614 S SARAN DR	90045	11	096B153   642	4119001800	C1.5-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Apartment			01/08/2010 12:00:00 AM			PC Approved	01/08/2010 12:00:00 AM	PIN	33.95910222	-118.4323763	DELTA 5, 6, & A FOR PCIS #07041-20000-27179. (NEW 49-UNIT APARTMENT BUILDING. Request for Modification to separate fire alarm submitted 11/8/07. Methane Detection/Mitigation System to be under seperate permit.) ADDED SUMP PUMPS AND ARCHITECTURAL CHANGES MADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65130	11041-20000-17415	609 W 7TH ST	90017	9	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Expired	06/01/2022 12:00:00 AM	ADDRESS	34.04764	-118.25687	Plan check for installing new equipment for telcomm center. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65131	14041-10001-05701	1712 N KEMPER ST	90065	1	148-5A217 368	5455011005	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	ADDRESS	34.10048	-118.23139	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 1.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(6) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65132	17041-10001-42332	5971 W VENICE BLVD 2ND & 3RD-FLOORS	90034	10	126B173   912	5066003021	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Issued	09/05/2018 12:00:00 AM	ADDRESS	34.03865	-118.37272	PC FOR CHANGES TO APPROVED SET (MEDICAL OFFICES) UNDER DELTA 1. SCOPE INCLUDES CHANGES TO FLOOR LAYOUT AND REVISIONS TO POWER AND LIGHTING LAYOUT, CHANGES TO FIXTURE SCHEDULE AND REVISIONS TO T-24.*****SEE NOTES******SCOPE INCLUDES REMOVAL AND ADDITION OF CIRCUITS.  TENANT IMPROVEMENT: INTERIOR REMODEL ; FULL PLAN CHECK ON FLOORS 2 AND 3 OF EXISTING CLINICAL SPACE (MEDICAL OFFICE) NO HOSPITAL.NEW PANELBOARDS AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65133	11041-10001-12293	717 W 9TH ST	90017		129A207   265	5144021040							Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM			PC Approved	01/05/2012 12:00:00 AM				New restaurant.  First time tenant on the first floor of a high rise building.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65134	13041-10000-26247	523 W 6TH ST	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Expired	10/16/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	REMODELING OF OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65135	13041-10000-24714	14722 W MAGNOLIA BLVD UNIT 2	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	PV2.  Instal 5.28 kW DC roof-mounted solar array of 22 modules, interconnect with apartment unit panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65136	15041-20001-30907	1601 N HOBART BLVD 1-54	90027	13	148-5A195 289	5544020010	[Q]R4-2	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			10/25/2018 12:00:00 AM			PC Approved	10/25/2018 12:00:00 AM	ADDRESS	34.09995	-118.30593	10-25-2018 Changes to an apporved set of plan changes include down size feeder MSBH-8 to 2 sets of 4#500 All changes has been clouded.  Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65137	15041-10001-01451	7337 W PACIFIC VIEW DR	90068	4	156B177   611	2428016005	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			Reviewed by Supervisor	01/29/2015 12:00:00 AM	ADDRESS	34.12144	-118.35321	13.77kW PV system. 2 Inverters, 1 4200 W, 1 6000W. 54 modules. 2 combiner boxes. Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65138	15041-20001-39323	10125 W PALMS BLVD 1-29	90034	5	120B165    94	4313001033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Apartment			11/20/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.0282	-118.40572	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM ON APARTMENT BUILDING. SYSTEM SIZE: 40KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65139	17041-20000-31207	801 S GRAND AVE Suite 725	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.04581	-118.25842	Plan check for Title 24 only. Project site is a suite in an existing high-rise commercial building. Project scope is a tenant improvement. Total lighting area = 1,825 sq. ft.Note: Building permit has been issued under 17016-10000-23142	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65140	19041-10000-49812	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	11/02/2022 12:00:00 AM	ADDRESS	33.94248	-118.40461	Energy plan check only, area of scope (11,000+)sqft approx	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65141	19041-10000-03427	6600 N TOPANGA CANYON BLVD 1084 C	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Issued	03/14/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PC T-24 ONLY FOR TENANT IMPROVEMENT FOR EXISTING RETAIL INCLUDING PARTITION WALLS AND NEW  MECHANICAL UNIT ON TOP OF NEW RESTROOM CEILING.NEW SUSPENDED CEILING   NO CHANGE OF USE. SCOPE OF WORK AREA 3,485 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65142	16041-10000-24449	12901 W CORAL TREE PL	90066	11	102B157    26	4211009005	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.97791	-118.42275	PC for energy only to a childhood center. Areas affected include: gym, offices, restrooms. Adding new lighting and power for receptacles and ac units. Total sqft = 8370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65143	16041-20000-28732	380 WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	01/25/2017 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI TO AN EXISTING COMMERCIAL SPACE (KIOSK).  NEW LIGHITNG NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 63.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65144	14041-20001-18202	4451 N CALLADA PL	91356	3	168B121   575	2177012019	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	34.15267	-118.54287	Expedite per customer request15KW PV1 roof-mounted system with (54) SolarWorld Plus SW280 Mono modules and 2 Sunnyboy inverters with SMA SB6000US and SB7000US.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65145	17041-10000-14269	3615 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	07/05/2017 12:00:00 AM	ADDRESS	34.02057	-118.35587	PC FOR T24 ENERGY ONLY. CHECKING LIGHTING TO REPLACE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65146	11041-20001-23345	8500 W BEVERLY BLVD Space# 150	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/22/2011 12:00:00 AM			PC Approved	12/22/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	Modification to an approved set of plans.  Mdification include the removal of 9 type C fixtures and the installation of 2X4 fixtures instead of 2X2.  All work is to be done in Space # 150.  Plan check is for energy only.  <<<<<<T.I for existing office space.  Plan check is for energy only.>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65147	17041-10001-44328	333 S CHADBOURNE AVE	90049	11	129B137   269	4406024012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.05124	-118.49043	DELTA 1 CHANGES TO APPROVED PLANS FOR ADDING A DISCONNECT SWITCH.Plan check for battery backup system for Single Family Dwelling. Total battery backup system size: 10kW with (2) PowerWall 2.0.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65148	13041-10007-35652	1455 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM			PC Approved	12/30/2015 12:00:00 AM	ADDRESS	34.09728	-118.31598	FIELD CHANGES CHANGES REQUIRED BY ELEC INSP : EM PANELS SUPPLIED THROUGH NEW 250 ATS ; COORDINATION STUDY; SINGLE LINE UPDATED TO INCORPORATE THE CHANGES((((((((((NEW 7  ELEVATED LEVELS AND 2 BELOW GRADE PARKING STRUCTURE PLAN CHECK. PLAN CHECK FOR POWER AND ENERGY. NEW 2000A UNDERGROUND, 480/277V,3PH,4W.building permit: 13010-10000-04219	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65149	18041-10001-41493	450 N BELLAGIO TER	90049	5	141B145   465	4368020023	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.07873	-118.46252	Changes to an approved set of plans. All changes are clouded delta 1. Changes include adding a 100A ATS and an AC disconnect. Revising Floor plans and single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65150	14041-10001-10231	13033 W TERRA BELLA ST	91331	7	204B161    25	2620027012	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.25946	-118.41701	Expedited RSES plan check per applicant request.{{PV1.Install 4 kW DC roof-mounted solar array on a 2 story-house, interconnect with main service panel.(1) Transformerless inverter: SOLAREDGE #SE3800A-US-ZB-U(16) Modules: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65151	16041-20000-00855	17849 W VENTURA BLVD	91316	5	171B129   260	2162012009	C2-1VL, P-1VL	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.16358	-118.52155	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 944 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65152	15041-10000-05328	525 E 87TH PL	90003	9	096A207   264	6041019013	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	33.95819	-118.2658	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 4708 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65153	15041-10000-23223	3745 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.01869	-118.35577	Energy plan check for a commerical building (wallgreen pharmacy) T.I; Scope include new lighting, receptacles and relocating sub panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65154	13041-10009-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Approved	06/09/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	06/09/16Changes to an approved set of plans. All changes are made under  detla 40. Changes are reflected on the feeder schedule and single line diagram. Each respective unit on the feeder schedule is reassigned to reflect what is on the field.(((((04/13/16Changes to an approved set of plans, note changes on delta 35. Changes include the addition of 3 security gate circuits, change fuse to a type L and addition of a receptacle. (((03/29/16Changes to an approved set of plans, Note changes on delta 34. Changes include the removal of light fixture and addition of a smoke guard door circuit. )))(((10/18/2015Changes to an approved set of plans. Changes are cluded on delta 28. Changes include the relocation of the inverter battery cabinet and adding block splices from MSB to RA-2. PC only.  )))(((REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  )))((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65155	13041-10000-21395	222 W 6TH ST	90731	15	015B201    93	7455020043	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			Corrections Issued	08/08/2013 12:00:00 AM	ADDRESS	33.73887	-118.28305	Office TI for highrise building.  Installation of new 2x4 fluorescent fixtures with LCP control.  Title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65156	13041-10000-05026	8131 S TRUXTON AVE	90045	11	099B165  1064	4107004019	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2013 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	33.96422	-118.39359	pv1 for 1-story house.  2.45 KW installation.  {10 modules - REC 245 PE BLK} {Microinverter: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65157	11041-10000-06510	10250 W SANTA MONICA BLVD # 133	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	alterations in the lighting systems at an auto dealership- interior and exterior lightingplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65158	13041-20000-04218	20439 W NORDHOFF ST	91311	12	195B109    61	2781001036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.232	-118.57907	PERMIT ISSUED FROM THIS APPLICATIONChange to lighting and loads.  Load is 273 amps per Engineer.  PLAN CHECK ONLY for Energy and Emergency.  Permit fees are under INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65159	12041-20006-05668	1340 S FIGUEROA ST	90015	9	126A205    86	5134010016	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			04/23/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.03951	-118.26852	CHANGES TO APPROVED SET OF PLANS. PLAN CHECK ONLY. DELTA  9 A CHANGES ONLY. INCLUSION OF FAULT CURRENTS. CHANGE OF FEEDER EF-06A, CHANGE OF SEWER DISCONNECT AND FUSE.NEW MIXED USE 171 UNIT APARTMENT COMPLEX, 7 STORIES WITH SUBTERRANEAN PARKING. PLAN CHECK POWER AND ENERGY. TWO SERVICES SUPPLYING BUILDING. METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65160	14041-20000-23765	17350 W LOS ALIMOS ST	91344	12	207B129   317	2696006002	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.26589	-118.51275	PERMIT FEE IS $0.00 BY STATE SENATE BILL NO. 122PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(56) KYOCERA KD 255 MODULES(1) FRONIUS INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65161	12041-20000-07104	3048 N COOLIDGE AVE	90039	13	150B213   779	5442022034	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	05/24/2012 12:00:00 AM	PIN	34.10492559	-118.24365041	Plan check energy and egress/exit lighting.(REMODEL EXISTING MANUFACTURING BUILDING WITH ACCESSORY OFFICE AREA.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65162	15041-20000-27275	22242 W ROMAR ST	91311	12	204B101   378	2745011029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.25477	-118.6121	Installation of new roof moutned solar PV array.  Total system size = 11.3 kW.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65163	14041-20000-05190	19350 W NORDHOFF WAY	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	05/23/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.23523	-118.55518	T24 FOR EXISTING RESTAURANT. OCCUPANT LOAD DOES NOT EXCEED 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65164	15041-10000-16161	7351 N WOODVALE CT	91307	12	186B093   694	2027006***	(Q)RD6-1, RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.20377	-118.63307	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP. Scope includes (20) Solar World-285 modules and (20) Enphase M250 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65165	13041-20000-35991	1167 W KIPLING AVE	90041	14	162A229   105	5691011023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.1391	-118.19144	pc for pv1 single family dwelling. total system size 6kw ac using 20 modules 2 transformerless inverters nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65166	11041-10001-10073	11674 W SANTA MONICA BLVD	90025	11	126B149   285	4262008018	(T)(Q)C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			Reviewed by Supervisor	07/23/2014 12:00:00 AM	ADDRESS	34.04379	-118.45551	Pc for power and energy. Changes have been made to the previously approved set. Clouded area is the changing area on the plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65167	13041-10000-26453	140 W ANAHEIM ST	90744	15	030B205   411	7423002042	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	33.77972	-118.26333	REMODELING OF AN YOSHNOYA RESTAURANT. PLAN CHK IS FOR TITLE 24. Applicant says panels are to be pulled under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65168	15041-20000-31678	14218 W LEMAY ST	91405	2	180B153   336	2237009005	R1-1-HPOZ	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.19184	-118.44273	PV1 SFD. TOTAL SYSTEM SIZE 3.4KWAC. TOTAL OF 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65169	18041-10000-13337	11960 W VENTURA BLVD STE 100	91604	2	162B169   148	2369016034	C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Info Complete	08/24/2018 12:00:00 AM	ADDRESS	34.14335	-118.39261	PC FOR COFFEE SHOP TI IN AN EXISTING RESTAURANT SPACE FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD  <400A.TOTAL AFFECTED AREa 722 sq. ftSCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. B# 18016-10000-09980	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65170	16041-10000-25999	5334 N ALHAMA DR	91364	3	171B105   311	2167024022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/22/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.1663	-118.59282	Plan check for Energy only. Main Service upgrade to 1200A, 120/280V, 3ph, 4W on (E) commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65171	13041-20000-06211	1016 N COLE AVE	90038	13	144B185   888	5533015018	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Info Complete	05/28/2013 12:00:00 AM	ADDRESS	34.08942	-118.32972	REMODEL AND 2,593 SF EXPANSION OF A HEALTH CLUB.  NEW 800 AMP SERVICE, LIGHTING, LOADS.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65172	19041-20000-52457	3810 N EAGLE ROCK BLVD	90065	1	154-5A217  91	5460003015	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	11/24/2020 12:00:00 AM		Permit Finaled	12/21/2021 12:00:00 AM	ADDRESS	34.11838	-118.23181	PV3.  Install 163.2 KW DC/151.39 KW AC CEC roof mounted PV system.  (480) modules with (1) 33.3 KW inverter, (1) 100 KW inverter, and (1) 200A panel.Permit fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65173	19041-20000-19171	4367 S BERRYMAN AVE 1-32	90066	11	111B161   460	4217007003	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			05/21/2019 12:00:00 AM			Reviewed by Supervisor	06/26/2019 12:00:00 AM	ADDRESS	34.00045	-118.41432	Plan check for Power and energy for new 5 story 32 unit multi-family dwelling1600A 120/240 Volt Delta ServiceB#18010-30000-02558	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65174	18041-10000-05922	7151 W MANCHESTER AVE	90045	11	096B161   668	4113013028	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	33.95996	-118.41843	FOR OFFICES IN A FINANCIAL INSTITUTION,  LUMINAIRE COMPONENT MODIFICATIONS ARE MADE- REPLACING LIGHT SOURCE TYPE TO LEDPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65175	15041-20000-38191	4535 N CONCHITA WAY	91356	3	168B117   555	2178028004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.15334	-118.55928	PV1, roof mounted solar panel, 9.805kW DC system (37)modules #KU2656ZPA, (1)inverter:FORNIUS #PRIMO7.6.  Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65176	18041-20000-41013	2005 N HIGHLAND AVE 1st Floor	90068	4	150A185   119	5549030013	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Issued	11/16/2018 12:00:00 AM	ADDRESS	34.10671	-118.33767	TI of (E) hotel common area lobby on first floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65177	10041-10000-17487	9401 N OAKDALE AVE	91311	12	198B113    96	2761040020	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	07/07/2011 12:00:00 AM	ADDRESS	34.24135	-118.56701	TI IN AN EXISTING 2 STORY OFFICE AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65178	19041-20000-52515	5026 N PETIT AVE	91436	5	171B137   351	2259014001	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	34.16215	-118.49556	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV. SYSTEM SIZE IS 10.05 KW DC/11.4 KW AC. SCOPE OF WORK CONSISTS OF (30) PV MODULES WITH OPTIMIZERS AND A 11.4 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65179	12041-20000-00627	6615 W HOLLYWOOD BLVD	90028	13	148-5A185 119	5547004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.10174	-118.33395	T.I. to existing building.  Install indoor general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65180	12041-20000-12520	915 W WILSHIRE BLVD	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM			PC Approved	05/31/2012 12:00:00 AM	ADDRESS	34.05069	-118.2599	T.I. to existing high rise building on 9th floor of suite 960.  Install general/emergency lighting.  Plan check for energy only.  Note: Permit issued under 11041-20000-24070	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65181	15041-10000-27520	7197 W FORMOSA FUSION CT	90046	5	141B181  1709	5525003034	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08567	-118.34599	PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65182	13041-10002-36145	7925 S NAYLOR AVE	90045	11	099B165   674	4107001012	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	33.96624	-118.39547	Expedited RSES plan check per applicant request.{{PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 200A MAIN IN A 1-STORY HOME. non-standard plan. SYSTEM SIZE IS 4.25 kW DC. (17)power  optimizers:Solaredge Op250-LV-MC4SM-2NA-Z   (17)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3800A-US.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65183	17041-10000-26170	3107 W BEVERLY BLVD	90057	13	138A201   209	5156010010	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM			PC Info Complete	09/22/2017 12:00:00 AM	ADDRESS	34.07209	-118.2824	PC FOR RESTAURANT TI (CHANGE OF USE) FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 1278 SQ. FT.SCOPE INCLUDES NEW LIGHTS RECEPTACLES EQUIPMENT AND CIRCUITS.Note: Permit is pulled under express permit application 18041-10000-06487.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65184	10041-10000-14328	1427 S ABBOT KINNEY BLVD	90291	11	108B145  1359	4241036007	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00, 2736.00	Electrical	Electrical	Commercial			07/23/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	33.99051	-118.46504	T.I. to existing restaurant.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65185	15041-20000-18919	10933 W ROCHESTER AVE SYSTEM 2	90024	5	132B153   743	4324005087	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.05602	-118.4436	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.8  KW. (80) 310W MODULES(2) FRONIUS 11.4-3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65186	18041-20002-35470	11415 N MONTALCINO WAY	91326	12	213B109   411	2701068022	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	ADDRESS	34.27894	-118.58674	5/30/2019changes to an approved set of plans.  changes to reconfigure pv feedback interconnection point and orientation of tesla gateway.this is plan check only.  ((((Plan check for batter back up system installed in to existing PV roof mounted. installed 3 Tesla PowerWalll 2.0 13.5kWh))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65187	13041-10000-06371	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/12/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	FIRST TIME TENANT RETAIL (GUCCI STORE). PLAN CHECK FOR POWER AND ENERGY. SQRFT 1218. LAX PROJECT. *SUBMITAL PER APPLICANT REQUEST*	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65188	18041-20000-28888	306 N CLIFFWOOD AVE	90049	11	132B137    56	4405012002	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2018 12:00:00 AM			PC Approved	09/26/2018 12:00:00 AM	ADDRESS	34.06151	-118.48676	single family dwelling 11,353 sq. ft. new 600 amps servise.this is plan check only.  permit fees paid under combo permit 17010-30000-00479	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65189	16041-10000-15862	5269 W OLYMPIC BLVD	90036	4	132B181   669	5084004032	C1-1	Central	Wilshire	Greater Wilshire		2162.00	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			PC Approved	05/23/2016 12:00:00 AM	ADDRESS	34.05737	-118.34521	RESTAURANT TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65190	17041-10001-43490	18901 W MUIRKIRK DR	91326	12	219B121   106	2820004027	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.29598	-118.54539	*expedited per applicant<<New solar system PV1 on a SFD, 11.5 kW AC. Install (32) AC modules, and (1) 125A solar load center.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65191	11041-20000-03622	444 S FLOWER ST 8th Floor	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	T.I. to a high rise building.  Install generarl/emergency lighting in restrooms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65192	19041-20000-39740	1369 W YOSEMITE DR	90041	14	160-5A227 340	5690018001	R2-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	PIN	34.13303339	-118.19580225	PV1.  Install 3.2 kW roof mounted grid tied PV system.  (10) modules with 3 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65193	13041-10004-04211	5520 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			08/01/2016 12:00:00 AM			PC Approved	08/01/2016 12:00:00 AM	ADDRESS	34.06209	-118.34912	Revised Lighting Plan to show that emergency luminaires are supplied from the inverter circuits and have  90-mins emergency  battery pack )))))))Plan check power and energy for 125 residential units and 50 joint/live work units apartment building over three level basement parking garage. 5000A service supplying building. Modification to separate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65194	15041-10009-14585	700-800 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	CHANGES TO THE APPROVED SET OF PLAN. PC FOR PLAN CHECK. CHANGES UNDER DELTA 40. ADDITION OF SOME LOADS TO EXSITING PANEL.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65195	14041-10000-08247	6255 W SUNSET BLVD SUITE 114	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	T24 FOR EXISTING COFFEE BEAN. CRA HAS BEEN CLEARED ON THE BUILDING PERMIT APPLICATION#: 13016-10000-26080	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65196	17041-10001-04549	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	changes to approved set. chages noted delta 11	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65197	08041-10002-12135	621 S WESTERN AVE	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM			PC Approved	04/05/2010 12:00:00 AM	ADDRESS	34.0628	-118.30928	DELTA 10 REVISIONS TO  THE  PROJECTION ROOMS AND OTHER AREAS THAT ARE SHOWN CLOUDED ON THE REVISED PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65198	19041-10000-19737	20680 W NORDHOFF ST	91311	3	195B109    12	2780001053	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.23524	-118.58338	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65199	10041-10000-08365	3601 S TROUSDALE PKWY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/05/2010 12:00:00 AM			PC Approved	05/05/2010 12:00:00 AM	ADDRESS	34.02017	-118.28558	Plan check T-24 energy for indoor and outdoor lighting at USC Gwynne Wilson Student Union. PERMIT WAS ISSUED ON 09041-10000-19634.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65200	16041-20002-19566	13710 W FOOTHILL BLVD #1 - #42	91342	7	222B153   920	2509014095	(T)(Q)C2-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			02/20/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.30854	-118.43227	02/20/2018 Plan check for a lost set of plans. Scope of work has remained the same. No revisions have been reviewed or approved as part of this restamp. *****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY. NEW 42 UNIT APARTMENT.  FIRE ALARM VARIANCE HAS BEEN SUBMITTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65201	10041-10000-13898	8500 W BEVERLY BLVD #  747	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	12/20/2010 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TI OF AN (E) 4017 SF RETAIL SPACE. PLAN CHK IS FO RTITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65202	14041-10000-22991	762 E 12TH ST #3	90021	14	123A211    63	5132012029	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.03266	-118.25146	T24, replace HID light fixtures with new LED fixtures. Total area 481 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65203	10041-10000-25804	2301 W BEVERLY BLVD	90026	13	136-5A205 225	5157011022	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.01	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM			PC Info Complete	01/25/2012 12:00:00 AM	PIN	34.0680608	-118.27300408	SERVICE UPGRAGE TO 1200 AMP, TI IN AN EXISTING BUILDING.  CORE & SHELL ONLY.  COMPLETE EPC REQUIRED FOR EACH TENANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65204	19041-10000-15792	6556 S WESTERN AVE	90047	8	102B193   118	6015012001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	33.9795	-118.30879	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65205	17041-10001-00345	15233 W LA CRUZ DR	90272	11	129B125   734	4412002016		West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM			PC Approved	01/24/2017 12:00:00 AM	ADDRESS	34.04577	-118.52516	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<< PV, ADDITION OF 6.9 KW DC ROOF-MOUNTED PHOTOVOLTAIC SYSTEM ON A COMMERCIAL BUILDING, WITH (23)  MICROINVERTERS: ENPHASE S280 (23) MODULES:  CANADIAN SOLAR 240 W TO AN EXISTING SYSTEM WITH ENPHASE M215 MICROINVERTERS (11041-10000-19354)>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65206	14041-10000-18209	912 N WESTERN AVE	90732	15	021B193   192	7445011015	RD1.5-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	33.75071	-118.30887	PROPOSED CHANGE OF USE FROM RETAIL TO RESTUARANT. T.I. IN EXISTING BUILDING SHELL W/ NEW NON-BEARING PARTITION WALLS, NEW KITCHEN EQUIPMENT, NEW FINISHES.  DEMOLITION OF EXISTING NON-BEARING WALLS AND FINISHES.  (1,502 S.F.).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65207	10041-10004-10084	530 W 27TH ST	90007	9	121-5A203 130	5123018019	(T)(Q) C2-2, D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.0269	-118.27607	Delta 5 modifications only to a new fire alarm system for a 5-STORY, TYPE III-A, 161-UNIT STUDENT HOUSING OVER TYPE 1-A, 2ND FLOOR GARAGE OVER TYPE 1-A, 1ST FLOOR COMMERCIAL LEASE SPACE / PKG, OVER TYPE 1-A BASEMENT PKG GARAGE (total 7-story building with one level basement parking per granted modification, see comments).((((( install new  voice evac fire alarm systems)))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65208	16041-10000-01600	400 S HOPE ST 4th-5th	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	PC for energy only, T-24. Existing offices, work being done on 4th and 5th floor. Adding new lighting and power. Total sq ft = 2310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65209	18041-10001-34954	624 N EVERGREEN AVE	90063	14	129A227   349	5178011029	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2038.00	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			Reviewed by Supervisor	09/18/2018 12:00:00 AM	PIN	34.04635602	-118.19840804	*Fee expedited per applicant**Install new rooftop solar system on one of 4 units apartment building. System size is 10.08 kW AC, scope inlcudes (42) CS6K-295MS modules, (42) Enphase IQ7-60-2-US, (1) Enphase combiner box	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65210	19041-10000-24316	1715 N BARDALE AVE	90731	15	024B193   275	7442012004	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	33.7603	-118.30052	[e-plan] CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF INVERTER AND ADDITION OF ELECTRIV CHARGING STATION - ALL CHANGES UNDER DELTA  A & BORIGINAL PERMIT 19041-10000-19585	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65211	19041-10000-35531	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Expired	09/20/2022 12:00:00 AM	ADDRESS	33.9427	-118.40223	ENERGY PC ONLY FOR TENANT IMPROVEMENT PERMIT FOR EXISTING SPACE RENOVATION IN A PORTION OF FCLUB LEVEL, CONCOURSE LEVEL, AND GROUND FLOOR LEVEL FOR A ADDITION OF A SINGLE PASSENGER ELEVATOR IN TERMINAL 6. AREA OF SCOPE 1,065SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65212	15041-10000-19735	800 N ALAMEDA ST #4	90012	14	132A215    65	5409023941	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.05494	-118.23752	"PC FOR POWER AND ENERGY. FIRST TIME TENANT.COFFEE/FOOD KIOSK""AND STORAGE ON THE GROUND FLOOR LOBBY OF UNION STATION. TOTAL AREA 300 SQ FT. Panel and transformer are not in scope per applicant."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65213	16041-20001-03842	4819 N GALENDO ST	91364	3	168B105   863	2171020047	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM			PC Approved	02/22/2016 12:00:00 AM	ADDRESS	34.15348	-118.60086	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 225A MSP, 200A Main.System size: 11.4kW. Ungrounded system. Each module has a 400W power optimizer.(42) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65214	15041-20000-28913	1412 W OAK GROVE DR	90041	14	159A227   117	5480026007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.13108	-118.196	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel. (14) Solar World SW 315 Modules(1) Solar Edge SE 3800 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65215	16041-10000-44612	3237 S LA CIENEGA BLVD BLDG 5.02	90016	10	123B173  1681	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.0289	-118.37369	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTING MEDIA FACILITY. SCOPE INCLUDES 3 NEW PANELS, NEW CIRCUITS, AND LIGHTS. NEW CONNECTED LOAD > 400A. TOTAL AFFECTED AREA IS 7523 SQ. FT. B#16016-30000-26999	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65216	19041-10000-37438	17511 W LEMAY PL	91406	6	180B129   308	2229016009	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.19122	-118.51478	PC FOR PV-1 SYSTEM. SYSTEM SIZE IS 5.700KW. (20) HANWHA Q-CELL MODULES WITH 320P OPTIMIZERS. (1) 3800 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65217	19041-20001-27226	7423 N TUNNEY AVE	91335	3	186B117   555	2116016056	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.20548	-118.55723	07-18-2019 Changes to an approved set of plan, changes include use the different manufacture for racking system, all change has been clouded.Fees $0.00 due to California Seante Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65218	19041-20000-06477	11972 W CHALON ROAD	90049	11	141B141   123	4429039008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	03/06/2019 12:00:00 AM	ADDRESS	34.08314	-118.47959	PC FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 15.2 KW AC, SCOPE OF WORK INCLUDES (40) 330W PANASONIC PV MODULES WITH P400 SE OPTIMIZERS, (1) 125A PV SUBPANEL, AND (2) 7.6 KW AC SE7600H INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65219	18041-20000-01538	7805 N BELLAIRE AVE	91605	2	189B161   852	2305038030	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Expired	05/18/2024 12:00:00 AM	ADDRESS	34.21228	-118.41121	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65220	15041-10000-03548	1458 S SAN PEDRO ST # 112	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	PIN	34.03045627	-118.25434986	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 616 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65221	18041-20000-33939	10711 N LURLINE AVE	91311	12	207B109   310	2706027007	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.2649	-118.58446	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 9.6 kWdc and consists of (1) 7.6 kWac rated inverter, (32) modules, (1) transformer, (1) load center, and (1) battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65222	14041-20000-31401	7504 N CHIMINEAS AVE	91335	3	186B125   464	2119007014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.20652	-118.52826	PV1 SFD. TOTAL SYSTEM SIZE 4.3 KW AC USING MICROINVERTER SYSTEM. USES ENPHASE M215. 20 MODULES TOTAL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65223	13041-20000-04317	8252 N VAN NUYS BLVD	91402	6	192B149   400	2212004001	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.22127	-118.44856	Full plan check for power and energy. Fitness club.  CLUB IS OPEN TO THE PUBLIC 24 HOURS A DAY 365 DAYS A WEEK PER APPLICANT - No time clock required.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65224	19041-10003-24186	6605 S OCEAN FRONT WALK	90293	11	096B149   322	4116002047	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	33.95981	-118.45206	Changes to an approve set of plans. All changes are clouded. Changes include relocating AC disconnects, inverter, and service equipment.Note: Permit Fees are paid under master application 19041-10000-24186	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65225	17041-10001-44778	4510 N BLACKFRIAR ROAD	91364	3	165B097    49	2076012033	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.15203	-118.62313	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65226	17041-10000-19233	131 N GRAND AVE	90731	15	018B197  1001	7451006027	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	33.7439	-118.29025	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING WITH LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65227	14041-10000-35258	19631 W PRAIRIE ST	91324	12	198B117   136	2761036030	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.23922	-118.56116	Title 24 plan check only.  Total area =7,410 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65228	15041-20001-26234	10336 N ENCINO AVE	91344	12	204B129   112	2733023035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.25876	-118.51528	Changes to approved set.  Module type changed.  One additional modules used.*****     Plan check for PV roof mounted system. System size: 6.8kW with 24 microinverters and 24 modules. Standard plan is being use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65229	17041-20001-06243	301 W 6TH ST	90731	15	015B201   132	7455012015	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	33.73862	-118.28366	[[[7/18/17 CHANGES TO APPROVED T24 ENERGY. PLANCHECK ONLY. CHANGES ARE CLOUDED. CHANGES TO LIGHTING LAYOUT]]]]TI to (E) restaurant space - interior alteration and exterior lighting.  Plan check for energy.  Building permit filed under 16016-10000-06349	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65230	11041-10000-11778	300 S EDINBURGH AVE	90048	5	138B177   769	5511027010	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			Corrections Issued	06/15/2011 12:00:00 AM	ADDRESS	34.0715	-118.36367	TI TO AN EXISTING BARBER SHOP.  PLAN CHECK FOR ENERGY, T-24 TAILORED METHOD.  PERMIT IS ON SEPERATE APPLICATION.  PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65231	11041-10000-20645	1061-1077 E ELKGROVE AVE BLDG 37	90291	11	111B145   346	4243003044	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.00214	-118.45939	LINCOLN PLAZA APARTMENT BUILDING PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65232	15041-20003-16378	940 S FIGUEROA ST basement-5th floor	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.04538	-118.26335	09/12/2016 Changes to an approved set of plans. Changes include the relocation of power equipment to a new electrical room. All changes have been clouded and marked as Delta 4. Note: Building application for the new electrical room is under 14016-10003-1352805/04/2016 Changes to an approved set of plans. Changes have been made to provide power to electrical equipment. Transformer has been added to change voltage class to power said equipment.02/18/2016  CHANGES TO APPROVED SET. ADDITION OF FIREPUMP AND JOCKEY PUMP TO THE SYSTEM REQUIRED BY MECHANIAL*****Previous Work Description*****New service upgrade and distribution equipment for assembly occupancy. new design. This is core and shell clear out of existing building. TI package will be submitted at a later date. per building submittal, PC is accordance to 2008 building efficiency standards.project is in methane buffer zone. NOT A HIGHRISE PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65233	18041-10000-26373	4760 W SUNSET BLVD	90027	13	147B197   733	5543015021	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.09788	-118.29343	"PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT FOR OUTPATIENT MEDICAL OFFICE. REPLACING EXISTING BOOMS IN ""OR"" ROOMS."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65234	15041-10000-28086	801 S FIGUEROA ST 1130	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Info Complete	08/26/2015 12:00:00 AM	ADDRESS	34.04789	-118.26153	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2710. SCOPE TO BE PERFORMED IN THE 11TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65235	14041-20001-22353	9348 N MCLENNAN AVE	91343	12	198B133   210	2687010018	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM			PC Approved	08/26/2014 12:00:00 AM	ADDRESS	34.24071	-118.50064	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.(49) KYOCERA KD255GX MODULES(2) AURORA PVI-5000 TRANSFORMERLESS INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65236	10041-20000-19995	21720 W VENTURA BLVD	91364	3	171B105    43	2168024049	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.16808	-118.60145	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65237	13041-10000-30807	718 N HIGHLAND AVE	90038	4	141B185   470	5524011026	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			11/05/2013 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.08414	-118.33839	TITLE 24 PART 6 ENERGY, LIGHTING WORK TO AN EXISTING RESTAURANT IN SINGLE STORY BUILDING. TOTAL ILLUMINATED AREA IS 585 SQ FT. SCOPE OF WORK < 400A . AREA IS FED FROM (E) 800A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65238	16041-10000-16327	445 S FERRY ST DCS SERVER-ROOM	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	33.74512	-118.26099	TI on (E) build. : install new light fixtures inside the DCS room. PC for T-24 only. Total area: 269 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65239	15041-10001-24059	1500 W PACIFIC COAST HWY Bldg E	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION of 96 devices and 2 power supply for future ADA requirement.(((NEW FA SYSTEM FOR A New 3-story, 5 unit apartment with garage, Typev VA construction. 100 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65240	14041-20000-33307	1920 N HILLCREST ROAD 1-20	90068	4	150A185   248	5549018022	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			12/02/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Closed	07/27/2018 12:00:00 AM	ADDRESS	34.10547	-118.33934	Plan check for power only. Upgrade 20-unit apartment service from 400A to 600A (single phase 3w). Install new switchgear and equipment. Add a new separate 100A single phase 3w service and combo panel for house loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65241	12041-10000-25257	3800 W WILSHIRE BLVD A;B;H;G	90010	10	132B193  1202	5093027***	C2-2, R4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.06139	-118.30931	T.I. TO COMBINE 4 (E) TENANT SPACES INTO 1  TO A DENTAL OFFICE (4,873 SF)OCCUPANT LOAD IS LESS THAN 100 AND ADDED LOADED IS 127ASUBMITTOR REQUESTED FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65242	17041-10002-41834	928 S BROADWAY	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.04154	-118.25658	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE REVISION OF LIGHTING SYSTEM AND FLOOR LAYOUTS. NOTE CHANGES ON DELTA 2. Plan check for first time tanent in mix use building West Elm. Total area: 10,930 sq ftB#13010-10000-02211	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65243	17041-20000-39331	8303 W KYLE ST	91040	7	207B189   449	2555012009	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM			Reviewed by Supervisor	11/08/2017 12:00:00 AM	ADDRESS	34.26486	-118.31376	Plan check for solar pv system, roof-mounted array on SFD.10kW ungrounded system. (35) 300W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65244	12041-10000-08796	18141 W RANCHO ST	91356	5	168B125   354	2184006007	RE9-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2012 12:00:00 AM	06/07/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.15715	-118.52924	PLAN CHECK INSTALLATION OF 15.5KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM WITH TWO CENTRAL INVERTERS AND ENPHASE M215 MICROINVERTERS. EXISTING SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65245	17041-10000-44395	1123-1137 S MAIN ST	90015	14	126A209   231	5139017027	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	34.03868	-118.25875	PC for T24 only for new outdoor lighting in new outdoor parking. Installing new 200A panel, new pole mounted lights, EV chargers, kiosk and receptacles. Total area 21961sqft. B# 17020-10000-00468	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65246	17041-10000-12000	15751 W ROXFORD ST	91342	7	222B141    45	2604002022	[T][Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Issued	04/13/2017 12:00:00 AM	ADDRESS	34.30837	-118.47526	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 25050 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65247	17041-20001-32368	18946 W KNAPP ST	91324	12	198B121   566	2762025017	RS-1	North Valley	Northridge	Northridge West		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.23821	-118.54651	EXPEDITED PER APPLICANTS REQUEST.PV1. ADDITION TO EXISITING PV SYSTEM. SYSTEM SIZE: 3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65248	16041-20003-23177	7900 N BALBOA BLVD Bldg Alpha	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM			PC Approved	11/06/2017 12:00:00 AM	ADDRESS	34.21347	-118.50092	11/617 - CHANGES TO APPROVED SET. PLANCHECK ONLY FOR DELTA 3 CHANGES. SWITCHING METER LOCATIONS ON SWITCHBOARD MSA.8.28.2017 - Plan check for modifications to approved set. Upgrade service from 200A to 600A. Panels A2-A7 are no longer being fed from their own meters, they are being fed from a tap off of a 125A feeder. Changes clouded.======Plan check for power, hazardous location requirements, and energy. Project site is a row of (9) new portable hangers referred to as the Alpha Building. Total lighting area = 17,480 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65249	19041-10000-52994	4215 W JEFFERSON BLVD	90016	10	120B181   694	5050025064	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			Reviewed by Supervisor	02/11/2020 12:00:00 AM	ADDRESS	34.02571	-118.34226	FULL POWER PLAN CHECK FOR A SERVICE OF 1600 AMP, 120/208 V, 3 PHASE 4 WIRE. SCOPE OF WORK INCLUDES NEW PANELS, 1 ELEVATOR, AND 1 EV CHARGER. (METHANE ZONE)  TOTAL AFFECTED AREA: 26,044 SQ FT   ---------*PER BUILDING APPLICATION: 19014-10000-06488**(3-STORY ADDITION RETAIL AND PARKING AT THE GROUND FLOOR, WITH TWO STORIES OF OFFICE SPACE ABOVE/RENOVATE (E) MIXED USE BUILDING CONSISTING OF COMMERCIAL AT GROUND FLOOR AND SINGLE FAMILY HOME AT THE SECOND FLOOR)**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65250	19041-10000-25012	520 E MANCHESTER AVE	90003	9	097-5A207 324	6041019003	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			06/28/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.95996	-118.26583	pc for commercial building new service 800A, 120/240V, 3ph, 4W.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65251	19041-10000-17700	20932 W DEVONSHIRE ST	91311	12	204B109   175	2747001048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.25702	-118.58975	PC FOR T24 ENERGY ONLY FOR (E) MCDONNALDS TAKE OUT RESTURANT. SCOPE INCLUDES NEW LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA 1490 SQ. FT B# 19016-20000-13668	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65252	16041-10001-44384	1011 N WESTERN AVE	90029	13	144B193   925	5536021024	C4-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM			PC Info Complete	10/16/2019 12:00:00 AM	ADDRESS	34.08906	-118.30941	"DELTA ""8"", ""9"", ""10"", ""11"" & ""12"" Changes to approved plans.Changes include: Reducing the LADWP Fault Current from 98KAIC to 33KAIC, Changes in Lighting & Loads."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65253	18041-20002-32872	19916 W TURNBERRY DR	91356	3	162B113    68	2180020006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.14091	-118.56751	12/28/2018changes to an approved set of plans.  changes to module type q.antum solar module 315W.this is plan check only.(((pv1install roof mounted pv system sized 12.8KW AC interconnected with msp.(42) 325 watt modules(2) inverters salivia)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65254	17041-20001-42581	24641 W STAGG ST	91304	12	189B089   300	2017027040	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.21256	-118.65721	expeditepv1install roof mounted pv system sized 7.6kw with battery back up interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65255	17041-30000-33502	2049 S CENTURY PARK EAST 19th Floor-RR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 onl. in existing highrise men and women restroom 19 Floor. Total area: 410 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65256	16041-20001-45172	5121 N WINNETKA AVE	91364	3	171B113   309	2166010008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2016 12:00:00 AM			PC Approved	01/06/2017 12:00:00 AM	ADDRESS	34.16392	-118.57148	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65257	18041-10002-15830	1547 N HAZELWOOD AVE	90041	14	157-5A221 268	5474012002	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.12437	-118.2147	Suppl. App for changes to approved plans for the changes in Trench Run. Plan Check Only.<<<PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (17) MODULES WITH OPTIMIZERS AND (1) INVERTER 3.8KWAC. TOTAL SYSTEM SIZE IS 3.8KWAC, 5.185 KWDC.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65258	18041-10000-07342	3132 S YALE AVE	90292	11	105B149   139	4229006081	R1-1	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	33.98738	-118.44778	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (12) MODULES AND (1) 3.8KW INVERTER. TOTAL SYSTEM SIZE IS 3.78KWDC AND 3.8KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65259	15041-20000-22459	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM			PC Approved	07/15/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	Title 24 plan check only.  Total area =1,369 sq. ft.  T.I. to existing restaraunt space located in highrise.  New lighting, recepticles, cooking equipment, and HVAC.  New connected load < 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65260	16041-10000-06635	14934 W BURBANK BLVD	91411	4	174B149  1255	2250015050	(Q)R3-1, R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Apartment			02/25/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.17186	-118.45859	New three-story, 11-unit apartment house over  subterranean private garage. 800MSA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65261	18041-10000-09006	2029 S CENTURY PARK EAST Suite ROL-15	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	07/16/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in existing high rise building T.I. in Concorse Level Basement, Mickey Fine Total area: 1118 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65262	14041-20001-06540	6902 N MAYNARD AVE	91307	12	183B097   682	2024027038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.19564	-118.62203	(((Expedite fees)))PV1 ROOFTOP TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. 7.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65263	18041-20000-01790	6138 N ALONZO AVE	91316	5	177B129   282	2123027019	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2018 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	02/22/2018 12:00:00 AM	ADDRESS	34.18159	-118.52195	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65264	13041-10000-22747	624 S GRAND AVE	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	New high-voltage substation on 4th floor for data center for NEC compliant protection of conductors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65265	17041-10001-44999	937 N SYCAMORE AVE	90038	4	144B181   686	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/01/2019 12:00:00 AM			Plans on Hold	03/01/2019 12:00:00 AM	ADDRESS	34.08824	-118.34291	PC ONLY, PERMIT FEES HAS BEEN PAID UNDER THE MASTER APPLICATION. PLAN CHECK FOR POWER FOR FIRST TIME TENANT PER INSPECTOR REQUEST ORIGINAL SCOPE-->(((PC FOR WAREHOUSE TI FOR TITLE 24 ENERGY ONLY.  SPLITING EXISTING SPACE INTO TWO SPACES FOR FUTURE TENANTS. INSTALLING MINIMUM LIGHTING AND EXIT SIGNS REQUIRED PER BUILDING CODE.SCOPE INCLUDES NEW LIGHTS AND PANELS. TOTAL AFFECTED AREA  6558 SQ.FT. B# 17016-10000-33840VOLUNTARY STRUCTURAL RETROFIT OF (E) LIGHT MANUF / WAREHOUSE. NO CHANGE OF USE.***  Project is subject to Change of Use per  ZA-2017-1968-CU, Resubmittal is required for change of use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65266	18041-10000-22756	1728 N VAN NESS AVE	90028	13	148-5A191  93	5586032016	RD1.5-1XL	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM			Reviewed by Supervisor	06/27/2018 12:00:00 AM	ADDRESS	34.10258	-118.31569	Scope of work includes installation of new 5kw tesla storage system to an existing PV system and new main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65267	13041-20000-01809	3625 N POMONA ST PV-1	90031	1	141A225   376	5208020014	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	PIN	34.07884358	-118.20193968	SOLAR SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65268	11041-20000-14717	10850 W WILSHIRE BLVD #330	90024	5	132B153   338	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			Reviewed by Supervisor	07/26/2011 12:00:00 AM	ADDRESS	34.05923	-118.44139	PLAN CHECK POWER AND ENERGY FOR CHG OF USE FROM OFFICE TO DENTAL OFFICE - STE 330	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65269	19041-10000-23982	3019 W 6TH ST	90020	13	135B197   957	5077004009	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			06/21/2019 12:00:00 AM			PC Info Complete	12/23/2019 12:00:00 AM	ADDRESS	34.06385	-118.28777	PC FOR NEW 6 STORY 14 UNIT APARTMENT OVER FIRST FLOOR  TYPE IA  PARKING GARAGE.NEW 3 PH 800A 120/208 SERVICE WITH 3 TYPICAL UNITS. SCOPE INDLUDES NEW EQUIIPMENT. TOTAL AFFECTED AREA 14408 SQ.FT  (INDOOR AND OUTDOOR)B#19010-10000-00944F.A. MOD HAS BEEN PROCESSED AND PAID  FOR THIS PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65270	13041-20000-34372	6500 W SELMA AVE	90028	13	148-5A187 328	5547017001	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	34.09966	-118.33121	POWER AND ENERGY FOR LOWRISE HOTEL WITH 2000A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65271	19041-20000-53275	3921 N WAWONA ST	90065	14	157-5A217  73	5678020009	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	05/18/2020 12:00:00 AM	ADDRESS	34.12704	-118.23354	Plan check for PV roof mounted system, PV system size: 4.875 KW DC, 4.51KW AC with 15 PV Moduels and 1 inverter(5.0KW )	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65272	17041-20000-28698	4430 N BALBOA AVE	91316	5	165B133    68	2289016038	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.15179	-118.50478	Plan check for solar pv system, roof-mounted on SFD. Interconnect with 400A MSP.11.4kW ungrounded system. (39) 350W pv modules. Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65273	16041-10000-30612	1999 S AVENUE OF THE STARS 31ST FLOOR	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI TO OFFICE SPACE IN SUITE 3160. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65274	16041-20000-03152	1845 S PONTIUS AVE 3RD FLR	90025	5	126B153   198	4323026015	M2-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM			Not Ready to Issue	01/28/2016 12:00:00 AM	ADDRESS	34.04443	-118.44248	void	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65275	13041-10000-28355	3707 N SAPPHIRE DR	91436	5	162B137   525	2286010005	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.13796	-118.48727	PV1. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 7.5 kW. CENTRAL INVERTER STANDARD PLAN. (30) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65276	10041-10000-25157	3333 S MANNING AVE	90064	5	123B161   812	4316032011	R3-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.03112	-118.40638	ALTERATIONS IN THE DINING ROOM OF A HOME FOR THE EDERLYPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65277	14041-10000-04834	6500 W SELMA AVE	90028	13	148-5A187 328	5547017001	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.09966	-118.33121	INSTALLATION OF A NEW FIRE ALARM SYSTEM.  5 STORY BUILDING. FULLY SPRINKLERED. 3 PANELS AND 198 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65278	16041-20001-03755	1933 W 60TH ST	90047	8	105B193   328	6001013011	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM			PC Approved	05/17/2016 12:00:00 AM	ADDRESS	33.98529	-118.31272	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65279	13041-10001-35293	7007 W IMPERIAL HWY 100 & 200	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	33.93185	-118.41447	(( 5/7/2014 CHANGES MADE TO APPROVED SET (under delta 2):  SWITCHBOARDS AND AC UNITS ARE NO LONGER REQUIRED. PLAN CHECK FOR POWER ONLY. PERMIT HAS NOT BEEN PULLED ON THE MASTER APPLICATION))PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR LAX. GOING FROM WAREHOUSE TO OFFICE+WAREHOUSE.BUILDING PERMIT # 13016-10000-25741	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65280	11041-10001-24606	1500 S OLIVE ST	90015	14	124-5A207 184	5134023009	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/07/2012 12:00:00 AM			PC Approved	05/07/2012 12:00:00 AM	ADDRESS	34.03567	-118.26482	DELTA 4 REVISION TO APPROVED PLANS. PLAN CHECK NEW PANEL 'EGH' TO SEPERATE EMERGENCY LOAD ATS AND OPTIONAL STANDY LOAD BY ATS, AND CU EQUIPMENT REMOVED FROM SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65281	14041-20000-25117	12658 W SANDHILL LANE UNIT 1	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97735	-118.41444	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.38 KW INTERCONNECTED WITH MSP FOR UNIT 1.ZONING CLEARANCE UNDER THIS APPLICATION SHALL BE APPLICABLE FOR ALL SOLAR INSTALLATIONS UNDER THIS BUILDING.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65282	12041-20000-24092	21847 W VINTAGE ST	91311	12	204B101   583	2747018081	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.25226	-118.60481	PV Solar Installation for single family dwelling, using microinverters (n-phase) with service upgrade to 200 amperes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65283	18041-10000-05768	5266 W FOUNTAIN AVE 1-7	90029	13	144B193    52	5537012001	R3-1	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Public Safety Only			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.09489	-118.3042	new fire warning system for 7-units apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65284	16041-10000-20238	7123 S CRENSHAW BLVD	90043	8	102B185   742	4006033014	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Approved	06/09/2016 12:00:00 AM	ADDRESS	33.97526	-118.33108	T-24, PC FOR ENERGY ONLY. TI TO AN EXISING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4205 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65285	17041-20000-21528	5501 N RANCHITO AVE	91401	4	174B153  1059	2247005010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.17051	-118.43576	pv1install roof mounted pv system sized 5kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65286	10041-20000-15171	6723 N VARIEL AVE	91303	3	180B105    22	2148030036	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	08/13/2010 12:00:00 AM		Permit Finaled	10/12/2010 12:00:00 AM	ADDRESS	34.19267	-118.59303	PLAN CHECK T-24 ENERGY GENERAL/EMERGENCY LIGHTING FOR T.I. IN AN (E) OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65287	12041-10005-17970	380 WORLD WAY 5TH FL	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	AT THE TBIT 5TH FLOOR FIRST AND BUSINESS CLASS LOUNGES REMODELING, SOME LOADS WERE REMOVED FROM PANELS AND ADDED TO OTHER PANELS-THERE IS NO CHANGE TO THE OVERALL LOAD SUMMARYPLAN CHK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65288	11041-20000-26428	2936 W 8TH ST	90005	1	132B197   502	5077023024	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	34.05758	-118.29013	New 25.92 KW roof mounted PV system for a church with service upgrade to 400 amperes, reconnect existing loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65289	15041-20002-38263	20011 W VENTURA BLVD	91367	3	174B113   402	2164001022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	PIN	34.17207471	-118.56880689	01/05/2016 Changes to an approved set of plans. All changes have been clouded. Changes have only been made to the lighting floor plan. Changes include revisions to the lighting controls and luminaires. *****Previous Work Description*****Supplemental permit that covers PC#:15041-10000-38263, 15041-10000-41742This Permit ties to permit#15041-20000-34106, 15041-10000-38263*****Previous Work Description*****(((T-24, TI TO A MEDICAL BUILDING, SCOPE OF WORK INCLUDES NEW LIGHTING ONLY. BUILDING INCLUDES NO OUTPATIENT, NO SURGERY, AND NO OSHPD3 CERTIFICATE. TOTAL SQ. FT. 8753.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65290	17041-20000-46013	811 S BEACON AVE	90017	1	130-5A203 108	5142015020	R3-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.05253	-118.27375	new fire alarm 67 devices plus facp.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65291	15041-10000-11729	1025 S ALVARADO ST	90006	1	130-5A201 218	5136013006	C2-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.05114	-118.28045	NEW TWO STORY COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD LESS THAN 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 5723.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65292	15041-20000-43097	4610 S MAIN ST	90011	9	112-5A205 280	5109002051	C2-1VL	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	PIN	34.001623	-118.27360762	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (ADMIN. BLDG). SCOPE INCLUDES NEW LIGHTING IN AN OFFICE, MECHANICAL, AND STORAGE SPACE ON 2ND FLOOR. ADDING ONE HVAC UNIT. TOTAL AREA IS 480 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65293	13041-10000-35418	826 N LA CIENEGA BLVD	90069	5	141B173   115	5529006057	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.08614	-118.37626	Interior nonstructural remodel of (E) restuarant and add outdoor dining.  Title 24 plan check only per supervisor request.  5,860 sq. ft. interior conditioned and 785 sq. ft.  illuminated hardscape area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65294	14041-20000-25880	5121 N COLBATH AVE	91423	4	171B153   579	2269007014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.16367	-118.43668	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING CENTRAL TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65295	15041-10001-10182	5450 W PICO BLVD SUITE 102	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.04862	-118.35714	SUPLEMENTAL TO AN APPROVED SET. DELTA ONE CHANGES. PERMIT TO  BE PULLED UDER THE ORIGINAL  APPLICATION.TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1335.  SCOPE OF WORK TO BE PERFORMED IN SUITE 102	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65296	19041-20000-22238	22135 W ROSCOE BLVD LOT #34	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/27/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 34.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65297	16041-10000-20305	5848 S SUNCATCHER PL	90094	11	102B161  1270	4211037208	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	33.97501	-118.41638	Installation of new fire alarm system in apartment building.  Total system size = 78 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65298	17041-20000-28130	1260 S VETERAN AVE	90024	5	132B149   167	4324003020	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.05654	-118.4465	"""0$ permit fees due to senate bill 1222""Plan check for roof-mounted solar pv system on apartment.(5) 7.6kW ungrounded inverters (38kW total system size).(150) 340W pv modules. Each module has a 400W power optimizer."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65299	13041-20005-05741	380 WORLD WAY space T71	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes from previously approved plans (13041-10004-05741) of LAX.  Change in one lighting luminaire wattage rating.  All changes indicate by Delta-27.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65300	12041-10001-13783	6510 N CANOGA AVE	91303	3	180B105    74	2148031018	WC	South Valley				1349.03	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	PIN	34.18937539	-118.59614207	REVISIONS TO PERMITTED SET OF PLANS; CHANGES ARE LISTED ON  ATTACHED  SHEET TO THE PLANST.I. OF EXISTING RETAIL  (DSW STORE)  AT THE WARNER MARKETPLACE SPACE INCLUDING DOORS, PARTITIONS, CEILING, FIXTURES, ETC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65301	15041-10000-15411	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	33.77884	-118.29327	ADDING EXTERIOR LIGHTING TO REFINERY FACILITY.  PLAN CHECK FOR HAZARDOUS LOCATION CLASS 1 DIV 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65302	17041-20001-00961	400 S GRAND AVE	90071	14	130-5A211  70	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05136	-118.2525	"08-21-2018 Changes to an approved set of plan. Changes include remove Medium Voltage feeder and refeed to new service, addion of power transfer switchboard, portable Generator will feed SWBD ""SBSA"", addional load added  panel ""P6"", added ""MCS-B"" sections,  All changes has been clouded. ((((((((two story addition to an existing high rise building, for new (2) 4160V services and optional standy equipment.  plan check for power and energy.2014 energy standards.)))))))))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65303	14041-20000-00680	3500 N MANDEVILLE CANYON ROAD	90049	11	153B133    66	4490021002	RE15-1-H	West Los Angeles			YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/24/2014 12:00:00 AM		Permit Expired	02/18/2016 12:00:00 AM	ADDRESS	34.11142	-118.49981	New 10.7kw Ground mounted PV system at a single family dwelling.  System is UNGROUNDED.  SERVICE PANEL SHALL BE ON A SEPARATE PERMIT.  Building Permit must be approved before electrical permit can be issued.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65304	16041-20000-14358	11784 W SHELDON ST #3	91352	6	198B169    38	2538003008	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.24206	-118.38966	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1344.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65305	19041-20001-02745	3868 S REDONDO BLVD	90008	10	117B177   278	5029004012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.01636	-118.35927	Expedite per applicant request Plan check for PV roof mounted system with Energy Storage System, system size: 14.4KW with 40 PV Modules and 1 inverter(11.4KW), LG Chem 9.8kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65306	18041-10000-17205	10281 W PICO BLVD	90064	5	129B161   327	4315014059	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.0486	-118.41341	TI IN AN EXISTING LOW RISE OFFICE BUILDING.PLAN CHECK FOR T-24 ENERGY ONLY ON THE 1ST FLOOR, 4TH FLOOR AND STAIRS.37,500 SQR FT. BUILDING PERMIT: 18016-10000-12651	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65307	14041-20001-12025	17808 W TULSA ST PV1	91344	12	210B129   836	2712020008	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.26835	-118.52189	pc for microinverter. original permit already issued. INSTALL ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM (4.8 KW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65308	14041-20001-26564	7701 N PENFIELD AVE	91306	3	189B113  1228	2106008018	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.21072	-118.56915	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(27) SolarEdge P300 power optimizers(27) Kyocera KD255GX-LFB3 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65309	17041-20000-08932	22828 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.18625	-118.62435	Plan check for energy only. TI to existing bank. New lighting (incl. emergency). 4,030sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65310	14041-10000-17560	950 S FAIRFAX AVE	90036	4	132B177   555	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	06/11/2018 12:00:00 AM	ADDRESS	34.05875	-118.3633	Fire alarm variance to be filed on 7/16/2015.PLANCHECK FOR POWER AND ENERGY. New mixed use, 5-story 144 unit apartment with retail and 2 level of subterranean parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65311	14041-20000-23214	6542 N WHITAKER AVE	91406	6	180B137   346	2231017004	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.18994	-118.4979	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.6KW INTERCONNECTED WITH MSP.(15) KYOCERA TSM-255 MODULES(2) ABB PVI-3.0-OUTD TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65312	14041-20000-23606	4645 N DUNAS LANE	91356	3	168B125   525	2184009012	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.15444	-118.53008	PV1.  (N) 12.2 kW DC ground-mount, utility-interactive PV system.  Interconnection to building electrical system shared with existing roof-mounted PV system.   Transformerless inverter with DC-DC converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65313	15041-20000-00664	422 E 107TH ST	90003	8	090A207   369	6063029006	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	33.93921	-118.26657	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.Derating the main breaker to 175A.System size: 8kW (inv1=5kW; inv2=3kW). Ungrounded system.24  327W pv modules across three strings (inv1=8+8; inv2=8)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65314	13041-20000-12826	14703 W GREENLEAF ST	91403	5	166-5A149 151	2276013002	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.14926	-118.45388	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.5 KW. USING ENPHASE MICROINVERTER. NONSTANDARD PLAN. TOTAL OF 14 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65315	19041-10000-50178	170 S SALTAIR AVE	90049	11	132B141   297	4404016002	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.0594	-118.47514	[EPLAN] NEW PV1 ROOF MOUNTED INSTALLATION WITH SYSTEM SIZE OF 8.58KW DC / 9.45KW AC  WITH 27 MODULES (LG350N1C), 27 MICROINVERTERS (IQ7PLUS-72-2-US), 1 COMBINER BOX, 1 ESS (SONNEN ECO- GEN 3 RATED 12.5), 1 200A SUB PANEL CONNECTED TO A EXISTING SERVICE PANEL RATED AT 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65316	15041-20001-06761	11507 W OXNARD ST Unit 2	91606	2	177B169   797	2338004012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			PC Approved	05/18/2015 12:00:00 AM	ADDRESS	34.1796	-118.38271	Plan check for first time tenant. Title 24 approved under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65317	14041-20001-12431	6554 N BONNER AVE	91606	2	180B173   554	2336003002	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	34.18993	-118.37358	Expedite by customer requestPV1,  3.5kw roof-mounted PV system with (14) module,  1 transfomerless  inverter and 1 optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65318	15041-10000-32505	115 S BIXEL ST	90026	1	133-5A209 144	5160016902	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Info Complete	10/01/2015 12:00:00 AM	ADDRESS	34.06007	-118.25726	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING FOR INDOOR AND OUTDOORS, NEW 200A PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65319	16041-10001-06833	1015 E ROBIDOUX ST	90744	15	033B209   176	7425017027	[Q]R2-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM			PC Approved	05/05/2016 12:00:00 AM	ADDRESS	33.78841	-118.25016	PC only, PV1 rooftop solar installation 5kW AC    (17) HiS-S280RG      (1) FRONIUS PRIMO 5.0-1.    Permit obtained online  #16041-90000-06833	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65320	14041-10000-10433	3846 S COCHRAN AVE	90008	10	117B177   216	5029006005	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Expired	05/16/2016 12:00:00 AM	ADDRESS	34.01664	-118.36146	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65321	18041-20000-19863	611 W 7TH ST	90017	14	129A209   115	5144006023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	34.04768	-118.25692	PLAN CHECK FOR T24 FOR - TENANT IMPROVEMENT OF EXISTING (3574 sq ft) RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65322	14041-20000-20503	13755 W ROSCOE BLVD	91402	6	192B153   739	2637029003	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM			PC Info Complete	10/03/2014 12:00:00 AM	ADDRESS	34.22182	-118.43315	(N) one story type V-B retail and restaurant spaces - core and shell.  600A, 120/208Y service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65323	17041-30000-03195	4701 N CAHUENGA BLVD	91602	4	168B177   716	2421019005	RD2-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1255.02	Electrical	Electrical	Apartment			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.15582	-118.36169	Installation of fire alarm system in new 3 story 7 unit apartment building.  Total system size = 53 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65324	14041-20000-16555	9110 S CENTRAL AVE	90002	9	094-5A209 133	6043008900	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	33.95357	-118.25622	TI for upgrading a new electrical service system with 600amp. Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65325	16041-10001-21926	18010 W CHATSWORTH ST	91344	12	207B125   637	2731008***	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM			PC Approved	01/23/2017 12:00:00 AM	ADDRESS	34.26474	-118.52445	01/23/2016 Changes to an approved set of plans, changes include removed scope of work, reduced amount of lighting fixtures installed and installed 2 new lighting fixtures. Title 24 exception Table 140.0 E less than 10% of enclosed space. Inspector to count existing lighting fixtures in the encolsed space to verify less 10% of existing fixtures being installed.  Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65326	12041-20000-07558	9144 N DEERING AVE	91311	12	198B105   160	2746010031	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	07/16/2012 12:00:00 AM	ADDRESS	34.237	-118.59594	T.I. to existing building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65327	17041-10000-40422	10201 W PICO BLVD EV-1	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	PC FOR POWER FOR  INSTALLATION OF 16 EV CHARGERS AT PICO WEST PARKING STRUCTURE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65328	18041-20000-42375	22139 W SHERMAN WAY	91303	3	183B101    65	2023009017	C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.20119	-118.60944	ti to an existing commercial building (medical office).  adding new receptacles only and running redundant grounding to existing circuits, no lighting.  plan check for power only.building application number 18016-20000-16993	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65329	11041-10000-10346	19345 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM			PC Approved	05/25/2011 12:00:00 AM	ADDRESS	34.18677	-118.55502	T.I.  EXISTING SINGLE STORY RETAIL SPACE.  REPLACING THE LIGHTS IN THE DRESSING ROOM.  TITLE 24 PLAN CHECK ONLY WITH EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65330	13041-20000-06949	12807 W MATTESON AVE	90066	11	111B153   987	4236015022	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Apartment			03/18/2013 12:00:00 AM			Reviewed by Supervisor	05/24/2013 12:00:00 AM	ADDRESS	33.99858	-118.4393	Plan check for power and energy new apartment. PC fees per applicant. 10 unit apartment. NOT a methane harzard site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65331	19041-20000-53260	110 E 9TH ST 8TH FL	90015	14	126A209   123	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	Plan check for Title 24 Energy only in existing space, Installed new lighting in addtion to existing lighting. Total area: 11,636 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65332	19041-10000-14665	8843 N DORRINGTON AVE	91331	6	195B157   668	2640024028	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.23037	-118.43139	PV1, ROOF MOUNTED SOLAR SYSTEM USING AC MODULES INTERCONNECTED TO A LOAD CENTER. (20) AC MODULES TOTAL SYSTEM SIZE IS 7.2KWDC AND 6.4 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65333	14041-20000-22553	18136 W LAKE ENCINO DR	91316	5	165B125   211	2184040025	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.1489	-118.52976	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORNERED INVERTER. TOTAL OF 24 MODULES. USING COMBINER BOX. point of interconnection ahead of the main disconnect	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65334	17041-20000-33906	1900 S ALAMEDA ST	90058	14	118-5A215  22	5167005017	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.01952	-118.23936	Plan check for power and energy. Project site is a new auto repair shop. Power plan check per Article 511. Project scope is a new 400-amp service and lighting. Total lighting area = 1,860 sq. ft.Note: Building permit has been issued under 17010-30000-02622	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65335	15041-20001-16325	936 S OLIVE ST UNIT 246	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #20 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65336	19041-10000-06553	2316 E IMPERIAL HWY SHADE-STRUCT.	90059	15	084B217    22	6067014901	RD2-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	33.92887	-118.23076	FULL PC FOR AN EMERGENCY HOMELESS SHELTER. SCOPE INCLUDES A NEW 800A 480V/277V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, AND NEW CIRCUITS FOR A SHADE STRUCTURE. TOTAL AFFECTED AREA IS 25750 SQ. FT. B#19010-10000-00752 APP # 3 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65337	19041-30000-18462	1037 S WESTWOOD BLVD	90024	5	132B149    34	4363018029	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.06175	-118.44559	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 820 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65338	11041-10001-02481	1021 S GLENDON AVE	90024		132B153  1086	4363021019							Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.062	-118.44436	TENANT IMPROVEMENT FOR BANK (4,009 s.f., B occup.)  First tenant in new commercial space((((((((((((((((((((((( change of lighting new title 24. existing ckts.)))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65339	15041-10000-11057	19811 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	33.85114	-118.28771	T24 ONLY, REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 5888 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65340	14041-10000-17046	925 N LA BREA AVE	90046	5	144B181   708	5531016020	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.08803	-118.34436	5 story mixed use office, retail, and 2 level parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65341	19041-10000-10852	1106 S WESTERN AVE	90006	10	129B193   670	5080010001	C2-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.05055	-118.30888	T-24, SCOPE OF WORK INCLUDES OUTDOOR HID FIXTURE REPLACEMENT TO LED FIXTURES. TOTAL SQ. FT. 4225.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65342	17041-10000-06384	2970 W OLYMPIC BLVD #102	90006	10	129B197   249	5078017023	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.05241	-118.29951	Plan check for Title 24 only in existing space, office T.I. Total area: 1,081 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65343	14041-10000-32162	1841 N GAFFEY ST	90731	15	024B197    78	7442022021	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Expired	06/29/2023 12:00:00 AM	ADDRESS	33.7616	-118.2932	Title 24 plan check only.  Total area = 6,337 sq. ft.T.I. to existing commercial space.  New lighting, recepticles, 3 30kVA transformers, and 3 100A panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65344	13041-20000-21697	589 E VENICE BLVD	90291	11	108B145  1542	4241037011	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	33.98988	-118.46173	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING OFFICE SPACE DOING RENEVATIONS. TOTAL SQRFT 19052. SCOPE OF WORK ON THE FIRST AND SECOND FLOOR AND ROOF (2 story building).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65345	13041-20000-14225	7841 N NOBLE AVE	91405	6	189B145   475	2209036021	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	34.2132	-118.46193	T24 FOR 1 STORY OFFICE SPACE. SCOPE OF WORK IN BATHROOM AND LOUNGE/OFFICE AREA. 392 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65346	17041-20000-13844	18035 W BURTON ST	91335	12	192B125   710	2101020017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.22001	-118.52641	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (45) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65347	14041-20000-13572	10330 N MT GLEASON AVE	91042	7	204B193   533	2558006001	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	Apartment			05/21/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	34.25679	-118.30254	New 600A service, switchboard, subpanels for 7-unit apartment with garage.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65348	14041-20000-20688	20041 W SEPTO ST	91311	12	201B113    28	2726003054	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.25115	-118.57057	Standard Plan: 8.415KW PV1 roof-mounted system including: (33) Trina Solar TSM-255 modules, and (2) Power-One PVI-3.6TL and 3.0-TL transformerless inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65349	19041-20000-14749	5161 N LANKERSHIM BLVD Ste 200	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.16452	-118.37469	TI to (E) commercial office space.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65350	12041-10000-22545	1748 W JEFFERSON BLVD	90018	8	120B193   738	5041004022	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			PC Approved	09/21/2012 12:00:00 AM	ADDRESS	34.02541	-118.30748	Ti in an existing store. Addition of lights at meat section. (Food 4 Less#359)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65351	14041-20000-25103	333 S HOPE ST 11th floor-restrooms	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM			PC Approved	09/12/2014 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for energy only. New lighting (incl. emergency) in bathrooms on 11th floor of existing high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65352	14041-10003-32855	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.07583	-118.37407	02/11/2016Changes to an approved set of plans,  Chipotle. Note changes on delta 8. Changes include the fault current calculations. (((CHANGES TO APPROVED SET NOTE CHANGES TO DELTA 7. SCOPE INCLUDES THE SPLIT OF A 800AMP SWITCH GEAR TO A NEW 400AMP DISTRIBUTION BOARD AND METHANE NOTE TO PLANS.))) (((CHANGES TO AN APPROVED SET OF PLANS.  CHANGES CLOUDED DELTA 5.  CHANGES INCLUDE LIGHTING AND LOCATION OF POWER EQUIPMENT.)))Plan check for power and energy. T24. Total area = 1694 sq. ft.   Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65353	10041-10000-16574	1273 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/02/2011 12:00:00 AM	ADDRESS	34.05156	-118.22537	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65354	13041-10000-12013	900 W WILSHIRE BLVD	90017	14	130-5A209 197	5144008020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			Reviewed by Supervisor	05/31/2013 12:00:00 AM	ADDRESS	34.05001	-118.25963	this Plan Check application is accepted in order to generate permits for conduit-only installations.These plans are for temporary and permanent up to street level	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65355	11041-10000-17104	727 N VINE ST	90038	13	141B185   430	5533031030	C2-1D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	ADDRESS	34.08428	-118.32679	TI TO AN EXISTING PHARMACY.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65356	17041-10000-06027	5521 N DUBOIS AVE	91367	3	174B093   431	2044005015	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.17085	-118.63999	PC for a PV 1 roof mounted solar system. Central inverter rated at 5.0 KW being fed from 24 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65357	16041-30000-11733	8124 W 3RD ST #200	90048	5	138B173   960	5511029032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.0721	-118.36676	Title 24 plan check only.  Total area = 5,210 sq. ft.     T.I. to existing commercial office space.  One new 200A subpanel.  New lighting & receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65358	18041-20001-23660	18559 W BRYMER ST	91326	12	213B125   282	2872019021	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.28104	-118.53699	change of word description to the following:Addition of (1) LG battery back up to an existing pv system.department error no fee.(((Plan check for power only. Project scope is the addition of a Tesla PowerWall onto an existing PV system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65359	17041-30000-12162	1888 CENTURY PARK EAST 17&18-Floor	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	PIN	34.06160176	-118.41389445	Plan check for Title 24 only in existing space T.I. in office area in 17 & 18 Floor. Total area: 2,880 sqft.B#17016-10000-08064	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65360	15041-20000-16253	15012 W VALERIO ST	91405	6	186B145   563	2221012003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.20472	-118.46043	Installation of roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65361	15041-10001-13617	10155 N BALBOA BLVD	91325	12	204B133   337	2694019023	C2-1VL, P-1VL, RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.25543	-118.50255	03/04/2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 3. CHANGES INCLUDE REMOVING THE SQUARE D LOAD MEASURE. (((SERVICE UPGRADE TO AN EXISTING SINGLE STORY COMMECIAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65362	19041-10000-29658	3702 W JEFFERSON BLVD	90016	10	120B185   879	5046002001	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM			Reviewed by Supervisor	09/25/2019 12:00:00 AM	ADDRESS	34.02545	-118.33656	FULL PC (POWER AND ENERGY) FOR A (N) 4-STORY MIX-USE, 3-LEVEL TYPE V-A, 60 UNIT APARTMENT OVER RETAIL & 1- LEVEL BASEMENT PARKING. SERVICE SIZE IS 1600A, 120/208V, 3PH, 4WIRE. AREA OF SCOPE 37,000SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65363	13041-10000-26455	539 3/4 N COMMONWEALTH AVE	90004	13	141A201   202	5539029008	R2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Apartment			09/24/2013 12:00:00 AM			Corrections Issued	09/30/2013 12:00:00 AM	ADDRESS	34.08048	-118.28575	PV1.  Install 1.5 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: Power-One Aurora PVI-3.0-OUTD-S-US.  6 modules: Hanwha HSL60P6-PB-4-250QW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65364	14041-20000-17097	10605 N BALBOA BLVD #225	91344	12	207B133   738	2695008026	(Q)CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.26259	-118.50249	T.I. to an existing high rise building on the 2nd floor.  Install general lighting.  Plan check for energy only.Note: Permit is under 14041-20000-15171	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65365	14041-20001-22361	8845 N OAK PARK AVE	91325	12	195B133   242	2690012007	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.23162	-118.50561	FEE CHARGE $0.00 BY STATE SENATE BILL NO. 122MODIFICATION TO AN APPROVED SET OF PLANS.  ADDING SIX KYOCERA KD255GX MODULES AND EXCHANGING SOLAREDGE INVERTER 6000 TO (2) SOLAREDGE 3800 INVERTERS.New roof mounted PV system with Optimizers.  Total system size 6KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65366	15041-10001-07369	13689 W FOOTHILL BLVD	91342	7	222B157    46	2509015027	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.30872	-118.43163	Change to approved set by modifying the panel schedule and removing panel LH.  Note, all changes are under clouded area only.(((TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS AND NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2245.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65367	16041-20000-19176	16000 W VENTURA BLVD Suite 880	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM			PC Approved	06/01/2016 12:00:00 AM	ADDRESS	34.15584	-118.48164	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,837 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65368	14041-20000-32452	7707 N GENESTA AVE	91406	6	189B133   938	2203009003	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.21062	-118.50346	PV1. ROOFMOUNTED SOLAR SYSTEM. UNGROUNDED MICROINVERTER SYSTEM. SYSTEM SIZE: 5KW DC(20) SOLARWORLD SW 275(20) ENPHASE M250 MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65369	18041-10003-09538	12020 W BURBANK BLVD	91607	2	174B165   752	2348002042	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.17198	-118.39447	pc for delta 1 only. change include upsizing transformers wires from #250 to #400 and changing the indicaitors on the transformer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65370	13041-10000-31250	380 WORLD WAY T46-R	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLANCHECK FOR T24 ENERGY ONLY ( SIGN LIGHTING) . LAX STOREFRONT SIGNAGE I STORE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65371	19041-10000-11310	6245 W WILSHIRE BLVD 102	90048	5	135B177   483	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			Verifications in Progress	04/04/2019 12:00:00 AM	ADDRESS	34.06356	-118.36478	PC for energy only. Tenant Improvement reasturant, Area scope 1228SF.YA 4/4THIS SCOPE IS SUPP. TO 18041-10000-41402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65372	14041-10000-01539	14635 W ARMINTA ST	91402	6	189B149   471	2210022054	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.2135	-118.45204	T24 PART 6 ENERGY FOR (E) COMMERCIAL BUILDING. TI IS FOR FIRE DAMAGED BUILDING. PROJECTED IN AREA OF LIGHTING WORK IS APPROX. 20,680 SQ FT( INDOOR + OUTDOOR) . SCOPE OF WORK < 400A.  PLAN TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65373	12041-20000-01994	8014 W MELROSE AVE	90048	5	141B177   616	5527015004	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Info Complete	01/31/2012 12:00:00 AM	PIN	34.0835083	-118.3643449	T.I. for the hair salon.  Install general lighting.  Plan check for energy only.Note: Permit under 11041-30000-23504.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65374	10041-10000-22082	310 W WASHINGTON BLVD BLDG #1	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 7 UNIT TOWN HOME.   (BUILDING #1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65375	15041-30000-39701	19507 W VANOWEN ST	91335	3	183B117  1018	2130015011	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Expired	01/10/2018 12:00:00 AM	ADDRESS	34.19397	-118.55817	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65376	17041-20000-06966	6026 N FULCHER AVE	91606	2	177B173  1046	2337003020	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.18017	-118.37306	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.6 KW  STANDARD CENTRAL INVERTER PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65377	12041-10000-25183	12777 W JEFFERSON BLVD	90066	11	102B161  1158	4211009033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2671.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM	12/05/2012 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	33.9778	-118.41768	Core & Shell upgrade for an existing 2 stories office Bldg. Relocate panels and site lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65378	15041-20002-00210	10825 N SEPULVEDA BLVD	91345	7	207B145   135	2664013023	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM			PC Approved	02/23/2015 12:00:00 AM	ADDRESS	34.26687	-118.46769	Plan check for Title 24 only. Project a TI for an existing restaurant. Total lighting area = 455 sq. ft.*****Previous Work Description*****LIGHTS, SWITCHES, OUTLETS IN BATHROOMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65379	13041-20000-20102	915 W WILSHIRE BLVD flr 7-flr 8	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM	07/29/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.05069	-118.2599	Plan check for energy and emergency lighting. Bathrooms for a commercial high-rise. 7th and 8th floors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65380	17041-30000-21160	339 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Issued	06/22/2017 12:00:00 AM	ADDRESS	33.7733	-118.27884	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 8,844 sq. ft.Note: Building application has been generated under 17016-10000-07373	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65381	15041-10000-35391	550 W 127TH ST	90044	15	081B201   249	6132002016	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Apartment			10/22/2015 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.91745	-118.28472	PC FOR POWER AND ENERGY. NEW 4-STORY, 85-UNIT APARTMENT BUILDING WITH 20 TYPES APARTMENT.  TOTAL AREA INCLUDES:  28165 SQ FT OUTDOOR + 4526 SQ FT CONDITIONED INDOOR + 13344SQ FT  UNCONDITIONED INDOOR LIGHTING.**fire alarm variance filed on 2/2/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65382	11041-10005-08478	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM			PC Approved	04/04/2013 12:00:00 AM	ADDRESS	33.94386	-118.4047	REVISION MADE TO PREVIOUSLY APPROVED SETS OF PLANS.CHANGES OUTLINED IN BULLETIN 9 ATTACHED TO THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65383	17041-20001-20186	1726 N NORTH SPRING ST Unit 1	90012	1	136-5A219  47	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.06983	-118.2261	10/6/2017changes to an approved set of plans.  changes include revisions to the lighting plan and energy calculations.  this is plan check only.(((((service upgrade to an existing commercial building 600 amps.  Plan check for power and energy. First time tenant - Interior remodel to office and add a mezzanine. T24 area - 5,409sqft.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65384	18041-30001-24074	1800 N VINE ST 1st Floor	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.10393	-118.3265	This is a plan check only to approved set. Revised light fixtures, updated T24 calculation, and updated photometric. All changes are clouded on the plan.<<Plan check for Title 24 only. Project site is the 1st floor of a 3-story commercial building. Project scope is a tenant improvement. Total lighting area = 13,310 sq. ft.>>Note: Building application has been generated under 18016-10000-14441	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65385	17041-10000-06226	1800 S AVENUE OF THE STARS 12TH FLR	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.06095	-118.41786	PLAN CHECK FOR ENERGY ONLY. TENANT IMPROVEMENT AT 12 TH FLOOR OF ( E ) OFFICE BUILDING, NEW LOAD < 400A, TOTAL AREA: 21,560 SQ.FT  (B# 16016-10000-29790)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65386	16041-20000-11036	13227 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.31115	-118.42909	PLANCHECK FOR POWER AND ENERGY. TI FOR A HEALTH CLUB .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65387	11041-20000-09758	1830 S WESTERN AVE Car Wash	90006	10	126B193   827	5074015045	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	06/17/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.04077	-118.30873	PLAN CHECK POWER AND ENERGY FOR CAR WASH EXPRESS TENANT. METHANE BUFFER ZONE REQUIREMENTS NOT APPLICABLE PER METHANE MITIGATION REPORT. CORE AND SHELL PLAN CHECK UNDER #11041-20000-01815	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65388	18041-10000-14293	8301 N LAUREL CANYON BLVD	91352	6	192B165   476	2633006019	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	34.22199	-118.3967	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CHASE BANK. 10441 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65389	16041-10000-00938	3350 W WILSHIRE BLVD	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Closed	02/19/2016 12:00:00 AM	ADDRESS	34.0615	-118.29586	INSTALL NEW FIRE ALARM SYSTEM FOR 12- STORY BUILDING + PLUS ROOF LEVEL, INCLUDING 109 FA DEVICES AND 1 FA PANEL AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65390	10041-10001-19514	8506 S OSAGE AVE	90045	11	096B173    97	4127024025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM			PC Info Complete	11/18/2010 12:00:00 AM	ADDRESS	33.96089	-118.37861	"mODIFIED PLAN.  tHE ORIGINAL WAS FOR ""T-24 lighting plan check for remodeled tenant space, convert into walk in coolers."" NUMBER 10041-10000-19514.  tHIS PLAN CHECK BECAUSE OF RELOCATING FANS ON ROOF.  nO CHANGE IN CALULCATION OR LOAD. THIS PCIS ID PLAN CHECK ONLY. PERMIT IS EXISTING. dELTA 1 DATED 11/18/10"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65391	17041-10005-44218	1650 S WESTMORELAND BLVD	90006	10	126B193   367	5074018004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2018 12:00:00 AM			Corrections Issued	10/09/2018 12:00:00 AM	ADDRESS	34.04303	-118.30641	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF EQUIPMENT AND TRENCH INFORMATION FOR FEEDERS GOING FROM MAIN PANEL TO SUBPANEL UNDER DELTA #2 ONLYSUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDING 50A MAIN BREAKER TO LOAD CENTER, AND CHANGING FEEDER SIZE FEEDING LOAD CENTER.  PC FOR ROOFMOUNTED PV ON SFD WITH ESS SYSTEM INSTALLED (UNDER SUPP. APPLICATION).SYSTEM SIZE 3.0KWAC ADN 4.4KWDC SCOPE INCLUDES 11 MODULES WITH OPTIMIZERS AND SINGLE INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65392	12041-10000-18473	380 W WORLD WAY UNIT #5310	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	09/26/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	TENANT IMPROVEMENT TO EXISTING OFFICE SPACE (3231 SQ FT) -NEW WESTFIELD MANAGEMENT OFFICES.   LOAD IS 98.5 AMPS.  PLAN CHECK ONLY FOR ENERGY, WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65393	13041-10000-08438	11611 W SAN VICENTE BLVD	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.0541	-118.46261	PLAN CHECK FOR POWER AND ENERGY. NEW TENANT OCCUPANT, DENTAL FACILITY WITH DENTAL EQUIPMENT. NEW TRANSFORMER AND TWO NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65394	17041-10000-19823	3576 N LOWRY ROAD	90027	4	154-5A203 292	5592008022	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			Verifications in Progress	08/03/2017 12:00:00 AM	ADDRESS	34.11638	-118.27726	Installation of new roof mounted solar PV system on existing single family dwelling with battery back up system.  One new Solaredge SE10000A with 32 Solarcity Standard SC325 modules and 2 Tesla AC Powerwall 5.8 kVA / 13 kWH batteries.       PC only.       Solar PV permit #17041-90000-15253Battery permit #17041-90000-15254	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65395	14041-20000-12406	13666 W FILMORE ST	91331	7	207B157   485	2619028009	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.26511	-118.43048	PV1Installation of roof-mounted solar array on SFD. System size: 4.25kW(17)  Enphase M215-60-240-S22 micro inverters(17) Canadian Solar CS6P-250P pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65396	14041-10000-30850	6600 N TOPANGA CANYON BLVD #1	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Expired	05/18/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR POWER AND ENERGY. lenscrafters medical in mall. emergency lighting provided. 3900SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65397	17041-10000-27334	850 W VENICE BLVD	90015	1	126A203   169	5135029008	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.03967	-118.27554	REPLACE EXISTING FIXTURES WITH LED FIXTURES T/24 ONLY. TOTAL SQUARE FT 28800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65398	15041-10000-25333	3454 E 14TH ST	90023	14	118-5A225 396	5190037004	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.01718	-118.20443	SERVICE UPGRADE TO 600 AMPS.  RECONNECT EXISTING LOADS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65399	13041-20001-23762	1345 W 251ST ST	90710	15	036B193   123	7410026056	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/07/2013 12:00:00 AM	ADDRESS	33.79685	-118.3005	((EXPEDITE FEES))PV1 TRANSFOMERLESS SYSTEM. 21 MODULES AND 1 INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65400	10041-20000-06092	915 W WILSHIRE BLVD 1660	90017	9	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	04/05/2010 12:00:00 AM		Permit Finaled	06/09/2010 12:00:00 AM	ADDRESS	34.05069	-118.2599	REPLACING EXISTING LIGHT FIXTURE AND INSTALLING NEW OUTLET FOR OFFICE AREA. THE P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65401	18041-20000-35972	865 S FIGUEROA ST Ste 2640	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.04653	-118.26275	Tenant improvement for (E) commercial highrise office building tenant suite.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65402	16041-20000-04524	10031 N DONNA AVE	91324	12	204B121   483	2729004007	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.25295	-118.5483	"""$0 permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 19 kWac and consists of (2) inverters, (62) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65403	14041-10000-03846	5469 W ADAMS BLVD	90016	10	123B177   948	5043001025	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.03263	-118.36204	"Alteration of (E) 2-story grocery store for bakery counter and facilities.  Title 24 plan check for changes to lighting system. ""COMPLY WITH DEPARTMENT ORDER effective date 04/01/2014. CALL INSPECTION PERMIT WITHIN 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65404	17041-20000-03181	22313 W SCHOOLCRAFT ST	91303	3	183B101   508	2024035003	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2017 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.19626	-118.61283	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65405	18041-10000-40365	17287 W VENTURA BLVD	91316	5	171B133   658	2258012026	(Q)P-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Info Complete	11/28/2018 12:00:00 AM	ADDRESS	34.16099	-118.50956	Energy plan check for an office T.I . Scope includes new lighting and equipment with a total area of 1,711-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65406	17041-10000-01749	4016 S CENTRAL AVE	90011	9	115-5A209 248	5114033033	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	12/19/2018 12:00:00 AM		Permit Finaled	01/24/2024 12:00:00 AM	ADDRESS	34.01063	-118.25627	FULL PC FOR POWER AND ENERGY FOR A NEW ONE STORY CHURCH (BLDG 2 OF 3, ONE SET OF PLANS SUBMITTED). SCOPE INCLUDES NEW PANELS AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 4535 SQ. FT. B#16010-10000-03363	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65407	18041-20000-08533	10078 W MCBROOM ST	91040	7	207B181   111	2543009007	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.26349	-118.35066	PV1.  Install 5.6 kW roof mounted grid tied PV system.  (20) modules with Enphase IQ6 Plus microinverters.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65408	18041-10000-02480	2825 W BELLEVUE AVE	90026	13	139-5A203 173	5402006006	C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.07689	-118.2754	PC FOR T-24 ENERGY ONLY FOR TENANT IMPROVEMENT TO A RETAIL SPACE. SCOPE INCLUDES NEW LIGHTING, EQUIPMENT AND RECEPTICAL.  TOTAL AFFECTED AREA IS 900 SQ.FTB#17016-10000-25773	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65409	11041-10000-00107	219 W 7TH ST	90014	14	127-5A211  40	5144002025	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	05/27/2011 12:00:00 AM	ADDRESS	34.04504	-118.25277	TENANT IMPROVEMENT - CHANGE OF USE FROM RETAIL TO DRINKING ESTABLISHMENT  ( RESTAURANT / BAR ); COMPLY WITH DEPARTMENT ORDER effective date07/20/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65410	19041-20000-52886	4545 N ENCINO AVE	91316	5	165B129    68	2290019003	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	01/20/2023 12:00:00 AM	ADDRESS	34.15223	-118.5142	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTE. SYSTEM SIZE IS 21.9 KW DC/20.44 KW AC. SCOPE OF WORK CONSISTS OF (60) PV MODULES WITH (2) 10KW INVERTERS AND A 125A LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65411	14041-10000-04631	6933 W HOLLYWOOD BLVD A-D	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.10171	-118.34135	PLANCHECK FOR POWER AND ENERGY. CHANGE OF OCCUPANCY TO THEATRE. TOTAL SQFT 5675. CONNECT TO EXISTING ELECTRICAL SERVICE AND INSTALL NEW 75KVA TRANSFORMER WITH PANELS AND CKTS.BUILDING P#  14016-10000-03072DEMOLITION OF SELECTED INTERIOR PARTITION WALLS APPROX. 35' L.F.  CONSTRUCT NEW 78 SEAT THEATER (74 FIXED SEATS & 4 WHEELCHAIR SEAT LOCATIONS, THEATER FOOTPRING APPROX. 2,400 S.F. INCLUDING ACCESSORY SPACES).  THEATER ENTRY,...(see additional comments)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65412	15041-20000-09972	9830 N MELVIN AVE	91324	12	201B117   184	2761033018	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	04/14/2015 12:00:00 AM	ADDRESS	34.24919	-118.56001	PV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING MICROINVERTER SYSTEM. USING ENPHASE M250. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65413	18041-10000-18278	207 S BROADWAY	90012	14	130-5A213  23	5149009067	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	09/15/2021 12:00:00 AM	ADDRESS	34.05231	-118.24703	INSTALL A NEW FIRE ALARM SYSTEM IN THREE HIGHRISE BUILDINGS SHARING A PARKING LOT.207 S. BROADWAY (W/ MAIN FIRE ALARM CONTROL PANEL), 205 S. BROADWAY & 316 W. 2ND ST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65414	13041-10000-16548	210 W 7TH ST GND FLOOR	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.04461	-118.25275	Alteration of existing building on ground floor (retail space) for new CVS pharmacy.  New 800A service and distribution system.  Power and energy plan check.Note: See 13041-10000-27739for landlord application for 300KVA XFMR AND METER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65415	13041-20000-22903	401 S VERMONT AVE	90020	10	135B197   497	5502009020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.21	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.06699	-118.29189	RENOVATION OF EXISTING RETAIL. NEW LIGHTING. TOTAL AREA 3828 SQ FT. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65416	14041-20000-22543	22908 W DOLOROSA ST	91367	3	174B097   823	2042008078	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Expired	09/19/2016 12:00:00 AM	ADDRESS	34.16948	-118.62603	PV1. Install 6.885 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65417	15041-20000-33467	21608 W BERMUDA ST	91311	12	207B105   146	2722030017	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	ADDRESS	34.2662	-118.60051	PV1. NEW ROOF MOUNTED PV SYSTEM ON EXISTING RESIDENTIAL HOUSE. TOTAL SYSTEM SIZE IS 11.20KW DC OR 9.8KW AC.(40) MODULES-SUNMODULE PLUS SW 280 MONO BLACK(2) INVERTER-FRONIUS PRIMO6.0 AND FRONIUS PRIMO 3.8 (1)100A LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65418	15041-20000-18668	1680 N VINE ST 4th Floor-Suite 400	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.10133	-118.32648	TI to high rise commercial (office) building. Plan check for energy only. Adding new lighting including emergency. Total sqft. 7,229.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65419	16041-20002-30563	2231 W 28TH ST	90018	10	123B189   985	5052018026	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			Reviewed by Supervisor	09/12/2016 12:00:00 AM	ADDRESS	34.03004	-118.31576	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65420	18041-10000-45153	212 N ARDEN BLVD	90004	4	138B189   623	5515017008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	02/02/2019 12:00:00 AM	ADDRESS	34.07504	-118.32584	PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV SYSTEM CONSISTING 1 CENTRAL INVERTER (SE7.6H-US) WITH 26 MODULES USING P400 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65421	11041-10000-02959	1071 W 190TH ST	90248	15	060B197   539	7351029002	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/15/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	03/16/2012 12:00:00 AM	ADDRESS	33.85848	-118.29445	TI IN AN EXISTING OFFICE. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65422	16041-10000-26958	1000 S HOPE ST	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.04346	-118.2617	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (OUTDOOR) 67480 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65423	19041-10000-50712	939 W SUPERBA AVE	90291	11	108B149   101	4241018025	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	02/19/2020 12:00:00 AM	ADDRESS	33.99571	-118.45819	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 9  (PANASONIC 330W) MODULES, 9  (ENPHASE IQ7X) MICROINVERTERS, 1 TESLA  POWERWALL, CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE: 2.97KW DC, 2.83KW AC. EV OUTLET UNDER SEPERATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65424	16041-20000-39440	8436 W 3RD ST	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.07301	-118.37448	Plan check for energy only. Change of use of office space to restaurant on ground floor of high rise building. New lighting (incl. emergency). 4,740sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65425	13041-10000-11091	2311 N WORTHING LANE	90077	5	153B141   216	4377041031	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	06/03/2013 12:00:00 AM		Permit Finaled	06/27/2013 12:00:00 AM	ADDRESS	34.11312	-118.47432	Upgraded service in 2-story single family dwelling from 400A to 600A.  New main service panel, new subpanel for pool features and new subpanel for 1st and 2nd floor power.  Panel A and associated wiring not part of scope of work (includes basement power and all lighting).  Power plan check for first and second stories only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65426	17041-10001-19527	14845 W VENTURA BLVD	91403	4	168A149   189	2264017026	(T)(Q)C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	11/16/2020 12:00:00 AM	ADDRESS	34.15238	-118.45654	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES ARE CLOUDED UNDER DELTA B,1, &A. CHANGES INCLUDE ADDITION OF NEW CIRCUITS, RELOCATION OF EQUIPMENT, REDESIGN ON LIGHTING LAYOUT AND UPDATING LOAD CALCULATION  PC FOR POWER AND ENERGY FOR NEW GROCERY STORE. NEW 3000A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65427	12041-10000-22224	331 E REES ST	90293	11	096B149   430	4116015014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	33.95866	-118.44537	PV1 ROOF INSTALLATION  OF A 4.16KW PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65428	18041-10000-35033	3429 W 6TH ST	90020	10	135B197   993	5502021001	(T)(Q)RAS4-1	Central	Wilshire	Wilshire Center-Koreatown		2121.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.06373	-118.29629	TENANT IMPROVEMENT TO (E) RESTAURANT.  PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65429	15041-10000-02952	1413 N L. RON HUBBARD WAY	90027	13	147B197   870	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	04/13/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	ADDRESS	34.097	-118.29419	Install exterior ceiling lighting. T24. Total area = 17,387 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65430	15041-20001-30788	6242 N WILBUR AVE	91335	3	177B121   231	2127013067	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.18405	-118.54455	EXPEDITED FEES FOR PV SYSTEM. (((PV1, ROOF MOUNTED SYSTEM. (55) MODULES AND 1 CENTRAL INVERTER. TOTAL SIZE 14.575KW. (55) KYOCERA #KU2656ZPA(1)SOLAREDGE #SE11400A-US-ZB-U)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65431	17041-10000-42171	700 S FLOWER ST STE 2990	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Issued	12/15/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC FOR TI TO (E) OFFICE SPACE FOR TITLE 24 ENERGY ONLY!SCOPE INCLUDES NEW LIGHTS, RECEPTACLE AND EQUIPMENT. TOTAL AFFECTED 3282 SQ. FT.PARTIAL PERMIT FEES PAID UNDER 17041-90000-45052 (FOR 38 CIRCUITS AND PANEL)B#17016-30000-26261	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65432	14041-20000-33767	12500 N LONGACRE AVE	91344	12	219B125   121	2601075056	RE20-1-K, RE20-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.29673	-118.53648	pv1install roof mounted pv system sized 9.8kw interconnected with msp.(32) sunpower x-21-335 modules (2) sunny boy inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65433	19041-20000-52867	6692 S PARA WAY	90094	11	099B157   523	4211027016	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	33.97126	-118.42266	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM. SYSTEM SIZE IS 5.27 KW DC/4.779 KW AC. SCOPE OF WORK CONSISTS OF (17) PV MODULES WITH OPTIMZIERS AND A 5 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65434	17041-20000-23833	6601 S CENTER DR WEST	90045	11	105B165   665	4104001033	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	33.97997	-118.39375	Plan check for energy only. TI to 6th floor corridors/restrooms and office suite 650 in high rise building.New lighting (incl. emergency) - 6,797sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65435	16041-20000-21180	10361 W DIAMOND ST LOT 1	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Issued	06/16/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65436	19041-10000-44052	701 N RADCLIFFE AVE	90272	11	126B125   332	4412006001	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Issued	12/06/2019 12:00:00 AM	ADDRESS	34.04319	-118.5307	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 3.8KWac(3.78KWdc) USING 12 Q.ANTUM (Q.PEAK DUO BLK-G5/SC 315) MODULES, 1 DELTA (SOLIVIA 3.8TL) CENTRAL INVERTER & ESS TESLA POWERWALL 27 KWH. CONNECTED TO AN EXISTING 200Amp SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65437	19041-10000-47528	3630 W WILSHIRE BLVD	90010	10	132B193    61	5093019001	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.06155	-118.30438	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65438	18041-10002-40738	17101 W VOSE ST	91406	6	183B133   413	2227023020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.19859	-118.50576	PERMIT FOR TWO NEW POWERWALLS AS PART OF PV SYSTEM (ROOF TILES). ALL OTHER ELEMENTS PERMITED UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65439	18041-20000-07171	515 S FIGUEROA ST #1040	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLAN CHECK FOR T24 ONLY FOR - INTERIOR TTI TO SUITE 1040 (2295 SF) ON 10TH FLOOR - TOTAL AFFECTED AREA = 2008 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65440	14041-10000-16584	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			Reviewed by Supervisor	07/07/2014 12:00:00 AM	ADDRESS	33.94502	-118.40714	TI in terminal 3 to add UPS.  Plan check for power and lighting.  Total area = 1,085 sq. ft.Provide lighting, electrical distribution, 20 kVA UPS system, and power fro 3 renovated spaces used as IT rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65441	16041-10000-36235	6330 W SAN VICENTE BLVD #540	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.06116	-118.36804	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT FOR AN EXISTING OFFICE SPACE FOR SUITE 540. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1437 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65442	18041-20000-06390	22030 W GILMORE ST	91303	3	180B101   726	2139003016	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.18741	-118.60727	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (14) modules. PV system is being interconnected onto a center-fed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65443	15041-10000-16136	10667 N ILEX AVE	91331	7	207B157   673	2620004001	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Expired	07/14/2017 12:00:00 AM	ADDRESS	34.26379	-118.42147	PV 1 ROOF MOUNTED SOLAR SYSTEM. 12 MODULES AND 1 INVERTER. TOTAL SIZE: 3.8KW. SUBMITTED PER APPLICANTS REQUEST. (12) SUN POWER SPR327NE-WHT-D(1) ABB PV1-3.8	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65444	14041-20000-25390	11675 N ODESSA AVE	91344	12	213B137   155	2610021005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/20/2014 12:00:00 AM	ADDRESS	34.28306	-118.49132	PV1Microinverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6.96kW.(29) EnPhase M250 microinverters(29) SolarWorld Plus SW275 Mono	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65445	15041-10000-11601	1900 S AVENUE OF THE STARS SUITE 520	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE OF WORK TO BE PERFORMED IN SUITE 520.  TOTAL SQUARE FOOTAGE 2170	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65446	18041-10001-47357	9330 N GOTHIC AVE	91343	12	198B137   424	2676007019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.2402	-118.4893	Plan recheck and restamp to replace a lost approved set. No changes to design or scope of work. Original Scope: ((NEW ROOFTOP SOLAR SYSTEM CONSIST OF 13 MODULES (Q-CELL 305) , 13 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.965KWdc and 3.8KWac))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65447	18041-10000-32529	5501 N FIGUEROA ST	90042	1	151-5A227 278	5468024007	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM			PC Approved	08/24/2018 12:00:00 AM	ADDRESS	34.10848	-118.19543	Energy plan check for a retail T.I. Scope includes new lighting and equipment  with a total Title-24 area of 1315-SQ FT.Note. Inspection verify if building permit is feeded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65448	18041-30000-01697	3571 W 3RD ST	90020	10	135B197   153	5518029001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2113.20	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.06919	-118.2937	Plan check for Title 24 only in existing space T.I. retail. Total area: 750 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65449	16041-20000-12863	5455 N VAN NUYS BLVD	91401	4	174B149  1115	2249003019	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	04/22/2016 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.17003	-118.44902	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 11,089 sq. ft.Note: Building application has been created under 16016-20000-05306	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65450	16041-10000-30023	8045 N WHITSETT AVE	91605	2	189B161   174	2308010901	OS-1XL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.21753	-118.4055	T-24, PC FOR ENERGY ONLY. TI TO EXISTING SPORTS FIELDS (BASEBALL FIELDS). SCOPE INCLUDES ADDING NEW SECURITY LIGHTS FOR THE LA CITY PARK SPORTS FIELDS. TOTAL AFFECTED AREA IS 12169 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65451	13041-10000-07631	1231 W MANCHESTER AVE	90044	8	097-5A197 303	6033013038	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	04/18/2013 12:00:00 AM	ADDRESS	33.96018	-118.297	PLAN CHECK FOR TITLE 24 ONLY ON OFFICE BUILDING. SERVICE AND LOAD < 400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65452	15041-20001-43500	3416 N FLOYD TER	90068	4	159B181   124	5579005025	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM			Reviewed by Supervisor	01/15/2016 12:00:00 AM	ADDRESS	34.13404	-118.34365	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65453	18041-10000-31780	10250 W SANTA MONICA BLVD 2775	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Issued	09/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR POWER AND ENERGY.  TENANT CORE AND SHELL IN SUITE # 2775 OF CENTURY CITY WESTFIELD MALL.1,149 SQR FT. BLDG PERMIT: 18016-10000-26066.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65454	13041-10001-27872	2226 S RAYMOND AVE	90007	8	123B197   302	5054018020	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	34.03547	-118.29741	][][]EXPEDITED PER APPLICANT REQUEST ][][]PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(12)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}. (E) 400 MAIN SERVICE PANEL, WITH (E) 4X60/2P MAIN CKT BREAKER.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65455	18041-30000-00457	11924 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.05236	-118.47067	Plan check for Title 24 only in existing space. T.I. Total area: 515 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65456	19041-20000-44779	9635 N HILLHAVEN AVE	91042	7	201A199   249	2563037041	RE15-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.24451	-118.29047	Plan check for PV roof mounted system, PV system size: 11.9KW DC, 11.026KW AC CEC  with 34 PV Modules and 1 inverter(11.4KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65457	10041-20001-17633	13576 W DESMOND ST	91331	7	210B157   125	2523005023	M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			10/20/2010 12:00:00 AM			PC Approved	11/15/2010 12:00:00 AM	ADDRESS	34.27454	-118.42833	Plan check only. Revision to approved plans. Revisions are changes to solar module model and changes to calculation on DC side. No changes to wiring.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65458	13041-20001-18106	16226 W BERTELLA DR	91436	5	168B137   793	2284016041	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2013 12:00:00 AM			PC Approved	08/12/2013 12:00:00 AM	ADDRESS	34.15326	-118.48675	Change to previously approved plans. 400A service.solar single family	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65459	18041-10001-25871	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM			PC Approved	04/11/2019 12:00:00 AM	ADDRESS	34.04797	-118.25815	"supplemental application for replacement of a lost approved set(((TI FOR NEW RESTAURANT ""JOEY"".  Full Plan Check for power and energy. 7440 sqr Ft.)))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65460	13041-10000-31728	4931 N LANKERSHIM BLVD A-D	91601	2	168B173    66	2353017001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			11/13/2013 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.16057	-118.37233	PLAN CHECK FOR POWER AND ENERGY. NEW ONE STORY COMMERCIAL BUILDING FOR 4 RETAIL STORES. 1200 A SERVICE. CORE AND SHELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65461	17041-10004-22182	1035 N SWARTHMORE AVE 1-105	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	"DELTA ""3"" CHANGES ONLY TO APPROVED SET. CHANGES INCLUDE REVISION TO LIGHTING, T24, ADDITION OF CIRCUITS, PANEL AND RELOCATION OF LOADS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65462	19041-10001-46471	451 W ELBERON AVE	90731	15	021B197   864	7448024010	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM			PC Approved	12/05/2019 12:00:00 AM	ADDRESS	33.75	-118.28842	CHANGES TO AN APPROVED SET. SCOPE OF WORK INCLUDES CHANGE TO SINGLE LINE DIAGRAM TO REFLECT FIELD CONDITIONS.***********************************************************************************NEW ROOF MOUNTED 4.72KW PV SYSTEM WITH 16 @ (295W) PV PANELS  AND 16@ ENPHASE MICRO INVERTERS ON A SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65463	18041-10001-35047	100 N JUNE ST	90004	4	138B185   233	5515003008	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM			Reviewed by Supervisor	02/05/2019 12:00:00 AM	ADDRESS	34.07414	-118.33414	Suppl Application for canges in design.Plan check for Power only on a Single Family Dwelling, Install New equipments: (1) 20kW Back up Generator,  (3) 4.8 kWh Battery Bank, (4) 5kW inverters, (1) 100A  AC combiner panel. There's existing PV system on site.<<PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.712 KWac. (24) AC MODULES-SUNPOWER SPR-250-BLK-AC (1) 100A LOAD CENTER+>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65464	15041-10000-22825	5880 W VENICE BLVD	90019	2	165B169   370	2368001028	[Q]MR2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	34.04068	-118.36772	INSTALLING NEW DISTRIBUTION BOARD TO POWER (2) SEWER GAS SCRUBBERS.  FULL PLAN CHECK FOR HAZARDOUS LOCATION CLASS 1 DIV 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65465	15041-20000-21205	23041 W ERWIN ST	91367	3	177B097   217	2039010004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM			Reviewed by Supervisor	07/15/2015 12:00:00 AM	ADDRESS	34.18294	-118.62923	PV1. ROOFMOUNTED SOLAR SYSTEM. 9KW DC.  CENTRAL INVERTER. NON STANDARD PLAN.34 KYOCERA KU 265 MODULES1  FRONIUS PRIMO 7.6KW INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65466	19041-20000-03776	6922 W HOLLYWOOD BLVD 7TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.10137	-118.34103	Plan check for Title 24 only in existing space Tentant Improvement office space high-rise building on 7th Floor. Total area: 7303 sq ft. B#19016-10000-00837	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65467	13041-10000-24128	17417 W NORDHOFF ST	91325	12	198B129   422	2766011055	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.23599	-118.51374	PV1 ROOF MOUNTED SOLAR INSTALLATION. PERMIT PULLED UNDER SEPERATE APPLICATION NUMBER. PLAN CHECK ONLY APPLICATION. SYSTEM SIZE IS 10.29 KW DC AND 7.5KW AC. [INVERTER: FRONIUS # IG PLUS V 7.5 |||| MODULES: TRINA SOLAR # TSM-245PC05]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65468	12041-10001-29962	11111 W SANTA MONICA BLVD 150	90025	5	129B153   651	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.04771	-118.44481	MODIFICATIONS TO APPROVED SET OF PLANS. SUITE NUMBER UPDATED TO 150, FEEDER TO PANEL PC AND CALCS UPDATED, BREAKER TO PANEL PC UPDATED FROM 200A TO 225A BREAKER.******************************************************12041-10000-29962 DESCRIPTION: FULL PLAN CHECK FOR ENERGY AND POWER. CHANGE OF USE FROM OFFICE TO COFFEE SHOP. PROJECT LOCATED IN A HIGH RISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65469	10041-20000-09188	737 W 28TH ST	90007	8	121-5A201  91	5123016401	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.02769	-118.28069	Alteration changing wiring for existing lighting fixtures and receptacles. Plan check is for title 24 for energy only. Permit for (6) panels under #10041-70000-09837.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65470	19041-10001-35933	17383 W SUNSET BLVD SUITE 101	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.03917	-118.55529	PLAN CHECK ONLY. CHANGES TO T-24 AND FLOOR PLAN FIXTURES LAYOUT AND COUNTS. PERMIT FEES ARE UPDATED ON THE MASTER APPLICATION. NEW TOTAL AFFECTED AREA IS 8070 SQ.FTORIGINAL SCOPE((((ENERGY PC ONLY FOR INTERIOR REMODEL OF EXISTING OFFICE SUITE ON 1ST FLOOR. AREA OF SCOPE 7,950SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65471	19041-20000-00489	10635 N WOODMAN AVE	91345	7	207B149   430	2648004045	(T)RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.26343	-118.45534	Fire alarm system for new 2-story multipurpose hall.  (80) devices with FACP and GSM communicator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65472	11041-70000-21713	7340 N GREENBUSH AVE	91605	2	186B157   480	2328026036	M2-1	North Valley	Sun Valley - La Tuna Canyon			1220.00	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.20351	-118.42616	t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65473	16041-30000-26310	19848 W MERRIDY ST	91311	12	204B113   595	2726006030	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.25256	-118.56575	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65474	16041-10001-39193	638 N SIENA WAY	90077	5	141B153   156	4362001022	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			PC Approved	01/07/2020 12:00:00 AM	ADDRESS	34.08263	-118.44568	Recheck plans for construction. (Engineer: Esteban)(((New single family home. Installing new electrical equipment. New Service rated at 1200 Amps 208/120V 3phase 4Wire. **Note:  Electrical permit fees have been charged under the building permit.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65475	16041-20000-11057	9301 N TAMPA AVE #82	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Title 24 only. Project site is an existing retail space. Project scope is a tenant improvement. Total lighting area = 1,921 sq. ft.Note: Building application has been created under 16016-30000-06564	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65476	17041-10000-04673	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	33.94221	-118.40701	T-24, PC FOR ENERGY ONLY. T.I. AT TERM-4. FIS ARRIVALS LEVEL 1 SCOPE INCLUDES NEW LIGHTS FOR KIOSKS, CONTROL ROOM. TOTAL AFFECTED AREA IS 17549 SQ. FT. B#16016-10000-30328	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65477	19041-20003-01962	12506 N MARVA AVE	91344	12	219B129   280	2601050016	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.29795	-118.51833	plan check only, supplemental for changes to approved set. clouded changes only. change of battery system from partial to whole house system, minor changes to single line diagram, relocation of loads, and change in conductors/conduit sizes*original*Installation of 13.5 kWh energy storage system, backup gateway, and 125 A critical load backup panel.  (E) 6.17 kW PV system on site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65478	14041-20000-33065	3330 N CAHUENGA BLVD WEST SUITE 200	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.13099	-118.35061	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES.  LIGHTING ONLY.  NO POWER LOADS INCLUDED IN PLANCHECK .NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. SUITE 200. 13594 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65479	14041-20001-07634	17703 W CANDIA CT	91344	12	219B129   271	2601050042	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.29804	-118.51999	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS. TOTAL SYSTEM SIZE 9.6KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65480	10041-20000-03467	14565 W LANARK ST	91402	6	189B149    17	2210011030	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	10/22/2010 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	34.21805	-118.45109	T. I WORK IN COMMERCIAL BUILDING OF NEW SERVICE OF 1000A .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65481	19041-10000-13414	6235 N LANKERSHIM BLVD	91606	2	177B169   228	2335032019	[Q]C2-1VL, [Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Issued	04/12/2019 12:00:00 AM	ADDRESS	34.18416	-118.38654	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65482	15041-10001-35007	12777 W JEFFERSON BLVD UNIT A	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			PC Approved	01/21/2016 12:00:00 AM	ADDRESS	33.9778	-118.41768	01/21/16Changes to an approved set. All changes are made under delta 3. Changes include relocating and removing lighting fixtures and receptacles. Note: pulled pulled under pcis#15041-10001-35007(((((Plan check for power and Title-24.  Total area = 29,729 sq. ft.TENANT IMPROVEMENT OF PARTIAL FIRST AND ENTIRE SECOND FLOOR TO EXISTING OFFICE SPACE; NEW TRANSFORMERS AND SUBPANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65483	17041-10000-10532	8720 N TILDEN AVE	91402	6	195B149   603	2638003005	R2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.22804	-118.44824	PV SYSTEM ROOF MOUNTED. 11 MODULES IN TOTAL AND CENTRAL INVERTER 3.8KW AC. THIS IS PART OF DUPLEX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65484	17041-10002-38547	9753 N SUNLAND BLVD	91040	7	201B177   231	2543032022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2017 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.24724	-118.35395	Supplementel for change in word description.INSTALLING NEW ROOFTOP SOLAR ON SFD, (10.08KW DC) 9KW AC SYSTEM WITH 28MODULES. ZERO FEES DUE TO SENATE BILL 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65485	14041-20000-33102	23924 W CLARINGTON DR	91304	12	186B089   193	2027041036	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.2085	-118.64934	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5 KW DC. (20) SOLARWORLD S250(20) ENPHASE M215 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65486	14041-20002-35068	1311 W SEPULVEDA BLVD	90501	15	045B193   791	7347018097	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	33.81492	-118.30044	9.22.2017 - Plan check for modifications to approved set. Update all unit feeders to aluminum. Update feeder between pull section and main service panel to aluminum. Delta A changes.======PC FOR POWER AND ENERGY FOR A NEW 6 STORY 176 UNITS APARTMENT BUILDING. TOTAL AREA 106800 SQ FT. B# 140410-10000-02205	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65487	19041-10000-33873	10419 W MYRNA ST	91601	2	174B177   931	2417011011	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.16963	-118.35752	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING 9 AC MODULES (SOLARIA 350 WITH 1Q7-72 MICROINVERTERS 290W) CONNECTED TO AN EXISTING 200A SERVICE. SYSTEM SIZE IS 2.61KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65488	14041-20000-11196	13816 N MINDORA AVE	91342	7	228B161   223	2511035017	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.32287	-118.41583	PV1.  Install 3.75 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65489	19041-20000-41383	11837 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM				PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65490	17041-10000-34480	233 N HARBOR BLVD	90731	15	018B201   480	7449014019	[T][Q]RAS4-1L-CDO	Harbor	San Pedro	Central San Pedro		2962.10	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	33.74482	-118.27992	PC FOR T24 ENERGY ONLY. PC FOR REPLACE LIGHTING WITH LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65491	19041-10000-18175	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	33.9427	-118.40223	Energy plan check per applicant request. Scope includes new lighting and equipment replacement with a total lighting area of 55-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65492	15041-10000-30408	13110 W BLUFF CREEK DR	90094	11	099B157   655	4211013044	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/15/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	33.96952	-118.42385	PLAN CHECK FOR CLASS 1 DIV 1 WATER TREATMENT. PERMIT IS ALSO ASSOCIATED WITH EXPRESS PERMIT 15041-10000-06378.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65493	10041-10000-21942	100 SWINFORD ST BERTH 93A	90731	15	018B201   130	7440026903	M2-1, [Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	PIN	33.7478016	-118.27948576	TI AT 100 SWINFORD ST. IN BERTH 93 (DISNEY CRUISE TERMINAL) IN THE BAGGAGE CLAIM AREA. ONE FOR ONE REPLACEMENT OF THE EXISTING HID LIGHT FIXTURES (452W) WITH FLOURESCENT FIXTURES (279W) .   PLAN CHECK IS FOR TITLE 24 ENERGY CALCS ONLY.  No new wiring.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65494	16041-10001-30820	621 W ROSECRANS AVE	90248	15	075B201    35	6132006031	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	33.90205	-118.28562	an interactive photo voltaic system will be installed on roof. total of 803 modules and 6 inverters. total system size is 216kw AC expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65495	12041-20000-07509	8408 W BEVERLY BLVD	90048	5	138B173   487	5511012005	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM	04/02/2012 12:00:00 AM		Permit Finaled	05/21/2012 12:00:00 AM	ADDRESS	34.07589	-118.37352	energy plan check retail lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65496	14041-20000-29239	4500 N AIDA PL	91364	3	165B097    63	2074037025	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.15181	-118.62464	PV1Using standard plan. One 5kW ungrounded inverter. 24 255W pv modules across two strings (14+10). Strings are combined ahead of inverter. Using 300W power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65497	17041-10000-42175	10546 N DEERING AVE	91311	12	207B105   552	2706028018	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	11/27/2017 12:00:00 AM	ADDRESS	34.26133	-118.59588	PC for rooftop solar for 9.24kW(AC) [10.065kW(DC)] for single family dwelling. Installing 33 modules with microinverters and new 60A combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65498	17041-10000-17169	3763 S WALL ST	90011	9	117A205   431	5121023003	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	Apartment			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Issued	05/23/2017 12:00:00 AM	ADDRESS	34.01319	-118.27108	Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system 4.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65499	18041-10000-10530	15739 W VENTURA BLVD	91436	5	168B141   552	2261009012	C4-1L, R1-1, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.15563	-118.47654	NEW ENTRANCE TO RELIGIOUS CAMPUS FACILITY AND ALTERATIONS IN STORAGE ROOMS   PLAN CHECK IS FOR TITLE 24 AND 1 EMERGENCY CKT-EXTERIOR AND INTERIOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65500	13041-10000-13862	4266 S LINCOLN BLVD SUITE K	90292	11	105B153    73	4230001018	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	07/26/2013 12:00:00 AM	ADDRESS	33.98605	-118.4435	Change of use space  on 2nd floor from medical office to beauty salon (1300 sq ft) and TI in 2-story building.  Suite K as per applicant.  New receptacles and lighting.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65501	18041-10000-20648	879 W 190TH ST	90248	15	060B197   499	6121021012	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	33.85951	-118.28963	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OUTDOOR FACADE LIGHTING FOR FOR 3 THRU 10. 14168 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65502	16041-10000-04260	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	"install new fire alarm system at the ""quantas Hanger"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65503	18041-20001-46379	4328 N VALLEY MEADOW ROAD	91436	5	165B141   240	2285003037	R1-1	South Valley	Encino - Tarzana	Encino	Yes	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM			PC Approved	12/21/2018 12:00:00 AM	ADDRESS	34.14979	-118.47615	Expedite per applicant requestPlan check for PV roof mounted system, system size; 24.48kW DC, 20kW AC with 68 PV modules  and 2 inverters(10kW) connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65504	13041-10000-33038	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM			Reviewed by Supervisor	05/23/2014 12:00:00 AM	ADDRESS	34.17307	-118.59314	NEW FIRE ALARM SYSTEM FOR BUILDING 37. 2 STORY, B OCCUPANCY. FULLY SPRINKLERED. 5 PANELS AND 226 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65505	15041-10000-39135	1651 E 114TH ST	90059	15	087A213   417	6069023031	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	33.93121	-118.24421	PV1, SOLAR ROOF MOUNTED SYSTEM, (12) MODULES AND (1) INVERTER. TOTAL SIZE 3.0KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65506	14041-10000-05963	231 W VERNON AVE	90037	9	112-5A203  33	5111010036	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.00394	-118.27727	PLANCHECK FOR POWER. UPGRADING OF SERVIVICE FROM 1000AMPS @ 208V TO 800 @ AT 480V FOR A MEDICAL DIAGNOSTIC CENTER. BRODWAY RADIOLOGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65507	19041-20000-24984	10412 N DENSMORE AVE	91344	12	204B141    48	2668015024	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.25973	-118.47815	pv1install roof mounted pv system sized 9.3KW AC consisting of (26) modules, (13) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65508	14041-10001-24537	6611 N WOODMAN AVE 1-30	91405	2	180B157   431	2238011007	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			Reviewed by Supervisor	09/16/2014 12:00:00 AM	PIN	34.190655	-118.43164511	EXPEDITED RSES PER APPLICANT REQUEST.<< INSTALL 13770 W DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(54)MODULES: SUNIVA OPT 265-60-4-100(2) INVERTER(S): SMA AMERICA SB7000US & SB6000TLUS>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65509	16041-20000-00443	8039 N CEDROS AVE	91402	6	189B149   191	2210016004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Expired	02/05/2018 12:00:00 AM	ADDRESS	34.21719	-118.45367	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (1) inverter and (21) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65510	14041-10001-30573	1837 S SAWTELLE BLVD	90025	11	126B149   405	4261021008	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.04291	-118.44567	03/04/16CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 1 ONLY. NO NEW LOAD ADDED, CHANGES INCLUDE THE RELOCATION OF 4 PANELS. (((New 5-story apartment, 19 units, with grade-level parking.  Plan check for power and energy.BLDG#14010-10000-03535. See additional comments.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65511	14041-10000-10152	12852 W RUNWAY ROAD	90094	11	102B161  1221	4211033040	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	33.97543	-118.41892	NEW METHANE GAS DETECTION SYSTEM. 24 DEVICES AND 1 FIRE ALARM CONTROL PANEL AND 1 CONTROLLER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65512	19041-10000-42620	1153-1159 N CYPRESS AVE	90065	1	145-5A219  22	5454025011	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	12/30/2020 12:00:00 AM		Permit Finaled	03/22/2021 12:00:00 AM	ADDRESS	34.09487	-118.22707	PC FOR POWER ONLY. SCOPE OF WORK IS SERVICE UPGRADE TO 800A (120/240, 3P.4W), INSTALLATION OF NEW SUBPANELS, AND A NEW 800A SWITCHBOARD. NOTE T-24 HAS ALREADY BEEN PERMITTED UNDER 19041-30000-16981.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65513	16041-10000-28384	18755 W MARTHA ST	91356	3	174B121   310	2156024008	R1-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.17386	-118.54256	PV1 roof mounted solar system installation to a single family home. Installing 12 microinverters rated at 327 watts each for a total system size of 3.92KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65514	17041-10001-18810	13186 W TONOPAH ST	91331	6	192B157    49	2627020004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.22675	-118.41982	Changes to approved set.  Change from existing 100 amp main panel to new 200 amp main panel.  Change location of service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65515	18041-10000-46179	1946 E 7TH ST	90021	14	124-5A217 256	5166016001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM			PC Approved	12/05/2018 12:00:00 AM	ADDRESS	34.03444	-118.2325	PC FOR ENERGY. TI: Interior remodel and exterior alteration, no change of use. ONE STORY BUILDING WITH MEZANINE. TOTAL AREA 2720 SQ FT.B#15016-10000-14057	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65516	18041-10000-08297	11160 N BALBOA BLVD	91344	12	210B133   327	2682021032	C4-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM			No Progress	04/19/2018 12:00:00 AM	ADDRESS	34.2736	-118.50196	Alterations for at a Chase bank- replacing outdoor and indoor luminaires with LED type using existing branch circuitsTotal area is 13540sqft.PLAN CHECK IS FOR TITLE 24	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65517	15041-20000-09359	6320 N CANOGA AVE SUITE1680E	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.18499	-118.59722	PLANCHECK FOR T24 ENERGY. TNENAT IMPROVEMENT FOR OFFICES. SUITE 1690E. 1541 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65518	15041-20000-16655	11037 N CANBY AVE	91326	12	210B125   472	2715002044	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	06/27/2015 12:00:00 AM	ADDRESS	34.27077	-118.53519	Plan check for PV 1 roof mounted system. System size 3.8kW with 17 modules(Trina solar TSM 250 PA05.05) and 1 inverter(ABB PVI 3.8)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65519	17041-10001-45892	813 N HARPER AVE	90046	5	141B173   148	5529010027	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.0858	-118.36932	SUPPLEMENTAL PERMIT # 17041-10000-45892 TO ADD SUBPANEL, 100 AMP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65520	18041-10000-02096	7653 N BURNET AVE	91405	6	186B145    38	2209034001	CM-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.20987	-118.46306	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65521	16041-20000-35623	12537 N KENNY DR	91344	12	219B137    46	2609021011	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.29808	-118.49847	"""$0 permit fees due to senate bill 1222 ""Plan check for a PV1 roof-mounted PV system. System size is 14.3 kWac and consists of (57) modules, (57) micro-inverters, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65522	11041-10000-09073	1334 S CENTRAL AVE	90021	14	121-5A213   5	5130008042	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.02855	-118.24651	TWO NEW 4,000 AMP SERVICES, NEW PANELS, AND EQUIPMENT LOADS FOR AN EXISTING COCA-COLA BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65523	13041-10000-18372	350 S GRAND AVE 3725 &-3750	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	PIN	34.05160512	-118.25169569	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING. NEW PARTITION WALL, CHANGES TO CONTROLS. FIXTURES REMOVED, AND RELOCATED. OFFICE SUITES 3725 AND 3750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65524	15041-20000-13036	16822 W GLEDHILL ST	91343	12	198B133   149	2687011009	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.24187	-118.49892	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65525	11041-20000-27360	1305 N GAFFEY ST Bldg. A	90731	15	021B197   135	7445002006	M1-1VL	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	09/12/2012 12:00:00 AM	ADDRESS	33.75593	-118.29257	"800A , 120/208V, ELECTRICAL SERVICE TO NEW 3-STORIES WAREHOUSE. Request for Modification to separate Fire Alarm system filed. 12042-10000-00730- Level II Methane Gas MitigationCONSTRUCT NEW 109'-4"" X 380'-0""  3-STORY , TYPE II-B, SELF-STORAGE BUILDING WITH  COVERED PARKING AREA. OPERATION HOURS 7AM~7PM. ZA 2010-1604 (CU). REFER PERMIT #11010-10000-01239 FOR PARKING GARAGE AND 11030-10000-03815 FOR GRADING PERMIT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65526	12041-20000-06304	2236 N GOWER ST	90068	4	151-5A189  60	5585021007	RD1.5-1XL	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	07/09/2012 12:00:00 AM	ADDRESS	34.11117	-118.32228	installation of a new PV system for a single family dwelling. roof mounted 2.88kW array with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65527	12041-10000-27220	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	PIN	33.93847109	-118.41935625	construction of Taxiway T and RON apron- power distribution system for aircraft power supply and airfield lighting	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65528	15041-20001-29390	9301 N SHOSHONE AVE	91325	12	198B129   214	2766020040	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM			Reviewed by Supervisor	09/14/2015 12:00:00 AM	ADDRESS	34.23982	-118.51791	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 16.4 kWac and consists of (2) inverters, (80) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65529	13041-10000-33040	7700 N FARMDALE AVE	91605	6	189B169   962	2316006012	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.21045	-118.38109	PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE5000A-US. (23) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65530	11041-10000-18289	1875 S CENTURY PARK EAST STE 1850	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2011 12:00:00 AM			PC Approved	08/30/2011 12:00:00 AM	ADDRESS	34.06115	-118.41457	TI TO AN EXISTING OFFICE BUILDING.  PLAN CHEKC IS FOR ENERGY ONLY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65531	18041-20002-24016			12	204B133   214	2694001031	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM			PC Approved	07/18/2018 12:00:00 AM	PIN	34.25706269	-118.50340461	Revisions to approved plans.  Change of circuiting on panel schedule and other changes not affecting Title 24 Part 6 plan review.  (((Plan check for Title 24  energy only in existing space T.I. hair salon. Total area: 1313 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65532	18041-20001-23252	22441 W HARTLAND ST	91307	12	183B101   703	2024029010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2019 12:00:00 AM			PC Approved	02/11/2019 12:00:00 AM	ADDRESS	34.19474	-118.61627	2-11-2019 Changes to an approved set of plans, changes include addtion of 2 disconnect to each of the Tesla Battery. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65533	18041-10000-38870	15739 W VENTURA BLVD	91436	5	168B141   552	2261009012	C4-1L, R1-1, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM			Reviewed by Supervisor	12/04/2018 12:00:00 AM	ADDRESS	34.15563	-118.47654	PLAN CHECK FOR POWER AND ENERGY FOR - ADD PLATFORM AND SCREENING FOR PROPOSED ROOFTOP EQUIPMENT PER 17016-10000-11099. ALL WORK PER ENGINEERING. - REPLACEMENT OF NEW 1000A SERVICE WITH NEW PANELS  WITH TOTAL AFFECTED AREA 18,183 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65534	16041-20001-30853	21650 W OXNARD ST #200	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	(112/7/2016)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES TO LIGHITNG FIXTURES AND ENERGY CALCULATIONS.  CHANGES NOTED DELTA 3 AND 4.  THIS IS PLAN CHECK ONLY.  (((Plan check for Title 24 only. Project site is an existing tenant space on the 2nd floor within a commercial building. Project scope is a tenant improvement/change of use from office to adult education. Total lighting area = 11,674 sq. ft.)))Note: Building application has been generated under 16016-10000-19273	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65535	17041-20000-40198	14523 W SHERMAN WAY	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.20136	-118.44972	ti to an existing commercial space.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65536	14041-10000-00446	1683 S WELLINGTON ROAD	90019	10	126B185   412	5071005026	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	ADDRESS	34.04334	-118.332	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PLAN. MICROINVERTER. SYSTEM SIZE: 4.75.(22) ENPHASE 215 MICROINVERTER(22) SOLARWORLD SW 260 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65537	14041-20000-33911	8812 N SPARTON AVE	91331	6	195B153   733	2640023008	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.23001	-118.43325	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(18) CANADIAN SOLAR CS6P-250P MODULES(1) SOLAR EDGE SE 3800 INVERTER(18) POWER OPTIMIZERS P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65538	18041-10000-18183	9301 N TAMPA AVE SPC# 12	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/16/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHEK FOR T24 ONLY, INTERIOR REMODEL TO EXISTING RETAIL SPACE. TOTAL AREA: 1416 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65539	16041-10000-18246	19057 W NASHVILLE ST	91326	12	210B121   691	2718011019	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.26867	-118.54834	PV1 SFD TOTAL SYSTEM SIZE 6.2KW AC USING 29 MICROINVERTERS. USING ENPHASE M215 NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65540	14041-20000-35859	1659 E 47TH ST	90011	9	112-5A213 345	5106014020	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	03/06/2015 12:00:00 AM	ADDRESS	34.00111	-118.24428	PV1. Install roof mounted PV system sized 10 KW. Interconnected with main service pannel. (32) Sunpower 327W Modules(2) PVI-5000- TL Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65541	19041-20000-52436	6840 W SANTA MONICA BLVD	90038	4	144B181   494	5532028018	MR1-1, [Q]M1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	01/19/2022 12:00:00 AM		Permit Finaled	07/15/2022 12:00:00 AM	ADDRESS	34.09049	-118.34008	Plan check for PV roof mounted system, PV system size: 149.2KW DC, 120KW AC with 373 PV Modules and 6 inverters(20KW) Permit fee $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65542	19041-10000-21378	1722 S SHERBOURNE DR	90035	5	129B169  1195	4303022001	R1V2	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.04722	-118.38041	Permit fee is $0.00 due to Assembly Bil 1414.pc for pv-1 system. system size is 13.08kw. system consists of 40 modules (E20-327-E-AC) w/microinverters and 125A load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65543	16041-10000-30673	3201 S HOOVER ST 8C2	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	09/20/2016 12:00:00 AM	ADDRESS	34.02548	-118.28442	Title 24 plan check only.  Total area = 920 sq. ft.    New lighting and receptacles in existing office suite.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65544	18041-10001-01907	10250 W SANTA MONICA BLVD #1530	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM			PC Info Complete	06/14/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"[Supplemental plan check and permit] Changes to approved set noted as Delta-4 on the plan. Scope includes revision on lighting floor plan, revise couple of lighting fixtures, revise T24 calculation accordingly, revise photometric accordingly, revise load schedule accordingly, add (2) new circuits.<<<Full Plan check for first time tenant space ""LACOSTE""  suite 1530 in Westfield Century City.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65545	16041-10000-34262	1150 S OLIVE ST 16TH FLR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.03962	-118.26181	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON THE 16TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 11906 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65546	15041-20000-09406	1679 S WEST BLVD	90019	10	126B185   472	5071013052	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.04303	-118.33615	PV1. ROOFMOUNTED. SYSTEM SIZE: 4.05 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65547	16041-30000-42748	6300 W WILSHIRE BLVD 1st Floor	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for Title 24 only. Project site is the 1st floor bathrooms of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 350 sq. ft.Note: Building application has been generated under 16016-10000-23753	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65548	19041-20000-36955	5750 S MESMER AVE	90230	11	105B165   299	4220015038	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	07/06/2020 12:00:00 AM		Permit Finaled	11/05/2020 12:00:00 AM	ADDRESS	33.98373	-118.39868	Full plan check for power and energy. New connected load exceeds 400 Amps connected to exiting 1,600 Amps Distribution. Total area: 111,800 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65549	19041-20000-42215	13402 N ANDALUSIA LANE	91342	7	225B157  1036	2510026001	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/09/2020 12:00:00 AM	PIN	34.31505833	-118.42219605	Plan check for PV roof mounted system, PV system size: 1.68KW  with 7 PV Modules and 7 microinverters, new sub-panel. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65550	17041-20000-34938	3136 N NICHOLS CANYON ROAD	90046	4	156B177    45	5570037006	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.12744	-118.36361	Plan check for AC coupled battery backup system for SFD.(2) 5kW Tesla Powerwall 2. Existing pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65551	12041-10000-00910	3305 N PASADENA AVE	90031	1	142-5A223 272	5205005043	[T][Q]CM-2D	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.08343	-118.21379	New 40KW roof mounted photovoltaic system installed on commercial building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65552	17041-20002-42258	555 W 5TH ST 1ST FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REMOVAL OF THE KITCHEN AREA AND REVISION OF THE SINGLE LINE DIAGRAM UNDER DELTA 6 AND 7. _______________________________________________________TENANT IMPROVEMENT OF WEWORK OFFICE SPACE (CHANGE OF USE TO OFFICE AND RESTAURANT), PC FOR POWER &  ENERGY.  CONNECTED LOAD > 400AMP. TOTAL AREA: 8681SQ FT.B # 17016-10000-11625	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65553	16041-20000-34178	12950 N SAN FERNANDO ROAD	91342	7	222B145   118	2501006042	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.30597	-118.46683	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for energy only.  total square footage 1738.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65554	10041-20000-11574	7045 W LANEWOOD AVE	90028	4	147B181   419	5548012009	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			06/17/2010 12:00:00 AM	09/19/2011 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.09933	-118.34304	Plan check power and energy for new 4-story 43 unit apartment building. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65555	18041-10001-20615	8510 N BALBOA BLVD	91325	12	192B133    87	2689019011	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.2251	-118.50158	"DELTA 2 CHANGES TO APPROVED PLANS FOR THE RELOCATION OF TWO EV CHARGER AND CHANGING ONE TO ""FUTURE"". <<<PLANCHECK FOR POWER AND ENERGY. ADDITION OF EV CHARGERS AND OUTDOOR LIGHTING.  81,827 SQFT.>>>BUILDING PERMIT # 18020-10000-00234"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65556	15041-10001-27123	12460 W OSPREY LANE 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	10/14/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	PV2 ROOF MOUNTED. TOTAL SYSTEM SIZE 1.84 KW ON COMMERCIAL 4-STORY BUILDING (BUILDING 8 UNIT 22) UNIT THREE(8) MODULES: SUNPOWER MODULES SPR-230NE-BLK-D(1) INVERTER PVI3.0 OUTD-S-US-A (POWER ONE) 240VACZONING CLEARANCES FOR UNIT 1,2, AND 3 INCLUDED.EXPEDITE PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65557	18041-30001-24243	13161 W MINDANAO WAY UNIT# D6A	90292	11	105B153    86	4212004004	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM			Corrections Issued	11/27/2018 12:00:00 AM	ADDRESS	33.98499	-118.43772	T-24 PLAN CHECK ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING TO AN EXISITNG SPACE. TOTAL SQ. FT. 1518.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65558	14041-20001-26938	12830 N WHEELER AVE	91342	7	222B161   369	2525003032	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.30331	-118.41616	Additional AC disconnect for front of house.  $0 plan check fee is due to State Senate Bill SB-1222.(((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65559	13041-20005-29804	1500 W PACIFIC COAST HWY A-L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			03/22/2016 12:00:00 AM			PC Approved	03/22/2016 12:00:00 AM	ADDRESS	33.79072	-118.2857	"03/22/2016 Changes to an approved set of plans. Revisions have been made to the available fault current. Fault current has been reduced to 82 kA available at the pull section, per LADWP. AIC rating of ""MSBA"" and ""DBH"" has been revised as necessary. All changes have been clouded.[[[[[ 3/10/16  CHANGES TO APPROVED SET.  REVISIONS TO FAULT CURRENT CALCULATIONS - CHANGE FROM 118 kA AVAILABLE FAULT CURRENT AT MAIN SERVICE TO PULL SECTION SPECIFIED BY DWP.  CHANGE OF MAIN SERVICE AIC RATING TO 100 kAIC AND MAIN SERVICE DISCONNECT RATING.  CLOUDED PORTIONS ONLY]]]]]BUILDING A:   NEW APARTMENT COMPLEX CONTAINING 12 SEPERATE BUILDINGS UNDER THE SAME ADDRESS. (2) 4000A SERVICES. PER APPLICANT REQUEST SUBMITTED AS ONE LUMP SUM. METHANE ZONE, HAS METHANE REPORT.Note: Variance to separate Methane Detection System has been filed.Permit Bld. B is under 14041-20000-06842Bld. C is under 14041-20000-06845Bld. D is under 14041-20000-06846Bld. E is under 14041-20000-06848Bld. F1 is under 14041-20000-06850Bld. F2 is under 14041-20000-06875Bld. G is under 14041-20000-06852Bld. H is under 14041-20000-06853Bld. I is under 14041-20000-06854Bld. J is under 14041-20000-06856Bld. K is under 14041-20000-06858Bld. L is under 14041-20000-06859Bld. Recreation is under 14041-20000-06860"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65560	12041-20000-21927	4123 N LANKERSHIM BLVD	91602	2	165B177  1037	2423030031	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Issued	09/14/2012 12:00:00 AM	ADDRESS	34.14468	-118.36261	Remodeling a portion of the second floor.   Installing lighting and receptacles to existing circuits, no new circuits.  Plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65561	13041-10000-26672	8256 N ORION AVE	91406	6	192B145   440	2654038016	[Q]CM-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.22055	-118.47197	PLAN CHECK FOR POWER AND ENERGY FOR TACO BELL RESTAURANT. LIGHTING WILL BE FOR BOTH INDOOR AND OUTDOOR. SCOPE OF WORK IS > 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65562	13041-10000-07693	16350 W VENTURA BLVD	91436	5	168B137   410	2284001055	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.15688	-118.48955	REMODEL EXISTING RESTAURANT-JERSEY MIKE'SPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65563	14041-20001-33776	16850 W CATENIA PL	91344	12	216B133   103	2609023030	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	12/24/2014 12:00:00 AM	ADDRESS	34.29156	-118.49967	expedite per customer request.pv1install roof mounted pv system sized 6.0kw interconnected with msp.(18) sunpower spr-x21-345 modules(1) sunny boy 6000 tl inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65564	15041-10000-22298	3785 W WILSHIRE BLVD #107E	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/16/2015 12:00:00 AM	ADDRESS	34.06187	-118.30858	TI to (E) restaurant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65565	15041-20001-06437	20321 W AETNA ST	91367	3	177B113   145	2149008010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.17902	-118.57625	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (58) modules, (3) inverters, and (1) 125-amp rated load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65566	12041-10000-11576	3650 S MCCLINTOCK AVE Floors 1-5	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/21/2012 12:00:00 AM			PC Info Complete	05/21/2012 12:00:00 AM	ADDRESS	34.02081	-118.28964	Plan check power for Delta B. New installatuon of inverter system for corridor (canopy) emergency egress lighting from floors 1 thru 5. All lighting in scope of work are existing to remaim.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65567	14041-10001-15469	6118 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	34.0978	-118.32305	((10/28/2014 - Sup. appliacation for changes to approved set.  new lighting fixtures.  Title 24 plan check only))NONSTRUCTURAL INT REMODEL - COMBINE EX RETAIL & RESTAURANT TENANTS INTO ONE RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65568	15041-10001-21917	751 E 90TH ST	90002	9	094-5A207  12	6042010014	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2015 12:00:00 AM			PC Approved	08/05/2015 12:00:00 AM	ADDRESS	33.95482	-118.26125	Expedited plan check fee per applicant request.  PV1.  Install 7.0 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65569	15041-10001-00405	787 S ALAMEDA ST	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Closed	10/20/2016 12:00:00 AM	ADDRESS	34.03365	-118.24048	REVISIONS TO PERMITTED SET OF PLANS: XFMR TMS RELOCATED INSIDE BUILDING NEAR THE MAIN ELECTRICAL ROOM; MAIN ELECTRICAL ROOM REDONE TO ALLOW XFMR TMS TO BE NEARBY OUTSIDE  ELECROOM  ;ADDED PANELS LA2 AND LB2 (NEAR MAIN PANELS) FOR RECEPTACLE CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65570	16041-10007-38144	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM			PC Approved	05/29/2019 12:00:00 AM	ADDRESS	34.26153	-118.50259	DELTA 7 CHANGES ONLY. UPDATE THE CONDUCTOR SIZE FROM COMBINER TO CENTRAL INVERTER.original PC # 16041-30000-38144	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65571	17041-20000-33209	1210 W VENICE BLVD	90291	11	108B149   298	4236003019	[Q]R4-1XL	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Apartment			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	PIN	33.99476794	-118.45045604	Replacement of defective fire alarm control panel and (1) new smoke detector.  Tie-in of existing devices to new FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65572	14041-20001-17382	9830 N LAUREL CANYON BLVD	91331	7	201B157   285	2622017005	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.24864	-118.42109	SUPPLEMENTAL PERMIT FOR THE ADDITION OF (3) HYUNDAI M250MG MODULES AND (3) ENPHASE M215 INVERTERS.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.5KW INTERCONNECTED WITH MSP.(14) HYUNDAI M250MG MODULES(14) M215 MICROINVERTERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65573	10041-20000-10645	4020 S BUCKINGHAM ROAD BLDG 1	90008	8	117B181   723	5032004010	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Park - Leimert Park	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			06/07/2010 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Closed	01/06/2012 12:00:00 AM	ADDRESS	34.01383	-118.34223	RE-CHECK A NEW 4-STORY 71 UNIT APARTMENT BUILDING (#1) BASED ON THE CURRENT CODES.   ORIGINAL PLAN CHECK WAS SUBMITTED, APPROVED AND EXPIRED (04041-20000-04793).  PER MR. PAT GILBERT, THE ORIGINAL EXPIRED PERMIT WILL BE RE-ACTIVATED. THIS PERMIT IS FOR 6 ADDITIONAL TRIPS.  VARIANCE WAS FILED TO SEPERATE THE FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65574	12041-10000-15901	806 W ADAMS BLVD	90007	8	123A201   233	5123003022	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.02974	-118.28024	Plan check for new fire alarm system. John Tracy Clinic (hearing impaired school for children) = more like a school/classroom (no medical precedures performed).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65575	11041-10001-26016	1122 W WASHINGTON BLVD 2nd floor	90007	1	126A201   241	5135014042	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2243.20	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			PC Approved	07/19/2012 12:00:00 AM	PIN	34.03848469	-118.28242224	Supplemental application to review plans. Previous plans were lost. T-24 and emergency lighting plan check for the second floor of the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65576	15041-20000-43770	22915 W SHERMAN WAY	91307	12	183B097    64	2021022008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.20116	-118.62605	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65577	14041-20001-02322	7412 W 80TH ST	90045	11	099B157   284	4114014015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	33.96364	-118.42678	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 3 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65578	11041-10000-07773	6253 W HOLLYWOOD BLVD #201	90028	13	148-5A189 343	5546030035	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM			PC Approved	05/04/2011 12:00:00 AM	ADDRESS	34.10179	-118.32624	Ti for an office Bldg. Epc for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65579	11041-10000-06167	15835 W MONTE ST	91342	7	225B141  1523	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			PC Approved	05/16/2011 12:00:00 AM	ADDRESS	34.31048	-118.4763	Ti in an existing commercial Bldg. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65580	17041-10000-06398	5015-5017 N LANKERSHIM BLVD	91601	2	171B173  1230	2353011002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Issued	07/12/2017 12:00:00 AM	ADDRESS	34.16119	-118.37261	PC PC FOR POWER ONLY. SCOPE INCLUDES A NEW 600A SERVICE/ DISTRIBUTION BOARD FOR A SHOPPING CENTER (BUILDING 2 OF 3).NOTE PLANS ARE SUBMITTED UNDER THE SAME SET OF PLANS. B#16016-30000-10373	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65581	19041-10000-07249	5965 S ST ANDREWS PL Hygn	90047	8	105B193   333	6001013906	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Apartment			02/28/2019 12:00:00 AM			Reviewed by Supervisor	03/08/2019 12:00:00 AM	ADDRESS	33.98626	-118.3116	NEW HOMELESS SHELTER.  Hygiene Building (3 of 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65582	15041-20000-43876	543 W 121ST ST	90044	15	084B201  1267	6117003014	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.92262	-118.28453	PV1, rooftop solar installation interconnect with 400A MSP. System size: 11.4 kw(44) Q.PRO BFR-G4(44) M215-60-2LL(1) 125A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65583	16041-20002-09548	16901 W NAPA ST	91343	12	195B133   508	2689018032	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			Permit Closed	09/18/2018 12:00:00 AM	ADDRESS	34.22679	-118.50046	[[[10/4/17 CHANGES TO APPROVED.  PV2. CARPORT PV SYSTEM ADDED TO EXSISTING PV SYSTEM. DELTA 1 CHANGES. ]]]] PV2. ROOFMOUNTED SOLAR SYSTEM.  TOTAL SYSTEM SIZE: 364 KW.   TWO BUILDING CONNECTED AS ONE FEED IN TARRIF SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65584	14041-10000-10320	13442 W SUNNYVIEW LN	91401	2	174B157   245	2343014038	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	PIN	34.17505543	-118.42608455	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65585	17041-20000-10846	10900 N WILLOWBRAE AVE	91311	12	210B105   220	2722037001	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.26828	-118.59839	pv1install roof mounted pv system sized 15.7kw interconnected with msp.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65586	13041-20000-32889	2122 S MIDVALE AVE	90025	5	126B153   208	4322001005	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Expired	12/18/2015 12:00:00 AM	ADDRESS	34.04416	-118.43319	PV1 SINGLE FAMILY DWELLING. USING MICROINVERTER ENPHASE M215. 20 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65587	16041-10000-10777	11109 N SEPULVEDA BLVD Suite 102	91345	7	210B145   124	2664007011	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.27256	-118.46785	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW 800A 120/208V 3PHASE 4WIRE DISTRIBUTION BOARD FOR A NEW TWO TENANT SHELL BUILDING ON EXISTING VACANT LOT. SHELL BUILDING TO INCLUDE RESTAURANT (SUITE 101) AND RETAIL (SUITE 102). ALSO ADDING TWO NEW 400A TENANT SUBPANELS AND ONE 200A HOUSE PANEL. TOTAL AFFECTED AREA IS 28405 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65588	15041-10000-32321	18650 W DEVONSHIRE ST	91324	12	204B121   133	2729011901	(T)(Q)RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			09/29/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Issued	09/29/2015 12:00:00 AM	ADDRESS	34.25711	-118.54099	NEW 600A SERVICE TO A FORMER RESIDENCE -NOW OWNED  BY LACITY AND NOT USED AS A RESIDENCE;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65589	18041-10000-35902	5336 E ALLAN ST	90032	14	141A237   191	5220024008	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	02/23/2019 12:00:00 AM	ADDRESS	34.08093	-118.16508	Plan check for a PV1 5kw AC / 5.28Kw DC roofmounted system with (16) module, and (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65590	19041-20000-47258	15449 W PARTHENIA ST	91343	6	195B145   501	2654013044	C2-1, QP-1, QP-1VL, [Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.07	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Issued	11/25/2019 12:00:00 AM	ADDRESS	34.22843	-118.4692	T24 ENERGY ONLY PLAN CHECK. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 4404 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65591	10041-10000-14029	8700 S BELLANCA AVE	90045	11	096B169   652	4125018004	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	02/03/2011 12:00:00 AM	ADDRESS	33.95896	-118.38039	Install outdoor lighting in a new parking lot.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65592	15041-20002-42620	300 S SANTA FE AVE WALKWAY	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	34.04587	-118.23239	02/02/2016 Changes to an approved set of plans. Changes were made to the fixture type of (4) downlights. All changes have been clouded and marked as Delta 2.*****Previous Work Description*****Change to approved set of plans. Changes include add 4 lighting fixtures and apply to delta 1 only. {{{{{{T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MIXED USED COMMERCIAL AREA (ONE SANTA FE YARDS ENCHANTMENTS). SCOPE INCLUDES NEW DECORATIVE LIGHTS. TOTAL HARDSCAPE AREA IS 22,162 SQ. FT.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65593	18041-10000-00102	430 N LECOUVREUR AVE	90744	15	030B209   873	7424005045	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.77548	-118.25538	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 25,000SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65594	14041-10000-18790	11100 W SANTA MONICA BLVD #100	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			07/11/2014 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.04726	-118.44465	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. SUITE 100  . 1828 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65595	14041-20002-06224	2421 N NALIN DR	90077	5	156B145   353	4378002021	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM			PC Approved	08/20/2014 12:00:00 AM	ADDRESS	34.11997	-118.46656	Fee is 0.00 base on senate bill 1222 from 2012. Down size PV module and optimizer from (21) to (16). Total wattage is 4.1KW, contractor also relocate some PV module on the roof top.(((PV1 TRANSFORMERLESS SYSTEM .TOTAL SYSTEM SIZE 5.0KWAC WTIH SOLAR OPTIMIZERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65596	18041-10000-45668	4455 E YORK BLVD	90041	14	157-5A221 297	5474009900	PF-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.12388	-118.21868	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65597	14041-20001-02954	17761 W SIDWELL ST	91344	12	219B129   655	2601071007	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.30072	-118.52147	((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 TRANSFORMERLESS INVERTER NOSNTANDARD PLAN.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65598	11041-20001-23978	10889 W WILSHIRE BLVD	90024	5	132B153   290	4363022019	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			PC Approved	03/13/2012 12:00:00 AM	ADDRESS	34.05908	-118.44352	Changes from previously approved plans.  Changes include lighting in the exhibit area.  Plan check for energy only.*****T.I.  Museum.  Adding addtional lighting to the entirior and exterior of the facility.  Plan check is for energy only.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65599	17041-10000-29224	633 W 5TH ST 69TH FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	PC FOR T24 ENERGY ONLY. TI ON 69TH FLOOR. FOOD SERVICE UPGRADES AND PHOTO AREA UPGRADES. ELECTRIC UPGRADES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65600	19041-20000-25797	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	33.97756	-118.41709	POWER AND ENERGY PLAN CHECK BY APPLICANTS REQUEST. T24 INCLUDED TOTAL SQUARE FOOTAGE = 3,047 SF. 1 225A AND 1 200A PANEL, AND 1 75KVA TRANSFORMER RELOCATED WITH 1 NEW 100A PANEL ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65601	11041-10000-15071	1230 S MENLO AVE 1-60	90006	1	129B197   936	5076019019	R4-1VL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			07/19/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Closed	04/16/2015 12:00:00 AM	ADDRESS	34.04815	-118.29051	NEW 30KVA PV SYSTEM ON ROOF OF NEW APARTMENT COMPLEX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65602	18041-10000-43496	2203 W VENICE BLVD	90006	10	126B193   231	5074012034	[T][Q]C2-2-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.04372	-118.30623	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65603	18041-10000-30726	515 S FLOWER ST 47th FLOOR	90071	14	130-5A209 125	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.05134	-118.25661	FULL PLAN CHECK FOR POWER AND ENERGY FOR TI - FULL FLOOR TENANT IMPROVEMENT ON THE 47TH FLOOR (HIGH RISE BUILDING)(21,252 S.F) OFFICE SPACE INCLUDING PARTITIONS, CIRCUITING OF LIGHTING, POWER, REDISTRIBUTION OF AIR FROM EXISTING AHU AND PLUMBING OF PANTRY SINKS.- TOTAL CONNECTED LOAD > 400A, TOTAL AFFECTED AREA = 22816 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65604	16041-10001-04556	9018 N NOBLE AVE	91343	6	195B145    81	2651019009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.23425	-118.46092	((EXPEDIOTE FEES)))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10.137KWDC. 31 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65605	17041-10000-29857	6360 W SUNSET BLVD	90028	13	147A187   584	5546015047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM			PC Approved	08/22/2017 12:00:00 AM	ADDRESS	34.09774	-118.32782	PLAN CHECK FOR TI ONLY FOR TI (in existing restrooms on 3 levels (basement, 1st level, 2nd level) of an existing movie threatre to include new finishes, plumbing, & lighting fixures). TOTAL AFFECTED AREA = 8410 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65606	19041-10000-52264	9851 S ALAMEDA ST	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00, 5354.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Approved	01/07/2020 12:00:00 AM	ADDRESS	33.94801	-118.22929	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1387 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65607	13041-20000-22801	2049 S CENTURY PARK EAST #3180	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM			PC Approved	08/23/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	Change to lighting on the 31st floor of an existing office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65608	17041-10001-08453	1320 W 47TH ST	90037	9	111B197   574	5017004030	R1-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	34.00052	-118.29889	CHANGE TO APPROVED SET OF PLANS. CHANGES TO LAYOUT AND UPDATED STRING WIRING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65609	13041-10000-23707	1928 N TAFT AVE	90068	4	150A191   116	5587018022	R1-1-HPOZ	Central	Hollywood	Hollywood United		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM			Corrections Issued	08/29/2013 12:00:00 AM	ADDRESS	34.10617	-118.31459	PV1. STANDARD ELECTRICAL PLAN . MICRO INVERTER ENPHASE 215. 44 MODULES - 3 STRINGS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65610	15041-10000-26843	1561 N MURRAY CIR	90026	13	144A205   286	5425004019	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.08874	-118.27323	pv1 install new 3.78 kw dc roof-mounted solar array on a single family home.(12) modules: lg electronics lg315n1c(1) inveter :solar edge se3800a-us	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65611	19041-10000-33898	8122 W BEVERLY BLVD	90048	5	138B173   442	5511005022	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.07592	-118.36664	FULL PC FOR  CHANGE OF USE & INTERIOR TENANT IMPROVEMENT OF (E) 3,700 SF RETAIL TO VETERINARY CLINIC. SERVICE SIZE INCLUDES (2)  EXISTING  240/120V, SINGLE PHASE AND THREE PHASES SERVICES..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65612	18041-20001-10516	10753 N TUJUNGA CANYON BLVD	91042	7	207B197   572	2557010002	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.26459	-118.29527	06-07-2018 Changes to an approved set of plan. Changes include remove Energy Storage system. All changes has been clouded. Plan check only.Fees $30.13 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65613	12041-10000-18807	240 E 6TH ST	90014	9	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			08/10/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.0435	-118.24761	Install a new fire alarm system in an existing apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65614	09041-10002-01614	504 N BERENDO ST	90004	13	141B197  1088	5520006010	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.10	Electrical	Electrical	Apartment			01/21/2010 12:00:00 AM			PC Approved	03/25/2010 12:00:00 AM	ADDRESS	34.07931	-118.2939	Plan check for revision to the single line diagram, and modifiy the disconnect switch from fused to non-fused as shown the plan.  See clouded changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65615	13041-10000-34637	4214 S LINCOLN BLVD	90292	11	105B153    50	4230001010	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	10/07/2014 12:00:00 AM	ADDRESS	33.98678	-118.44402	PLANCHECK FOR POWER FOR CORE AND SHELL.  600 AMP SERVICE. BUILDING PERMIT : 13010 30000 01558	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65616	19041-20000-04009	9937 N STANWIN AVE	91331	6	201B153    89	2645015030	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.2511	-118.4376	Plan check for a PV1 roof-mounted PV system. System size is 3.05 kWdc and consists of (1) 3.8 kWac-rated inverter and (10) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65617	11041-10000-04013	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			03/02/2011 12:00:00 AM			PC Approved	03/02/2011 12:00:00 AM	ADDRESS	34.05199	-118.25764	T.I. TO EXISTING HIGH RISE OFFICE BUILDING.  TITLE-24 ONLY.  15TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65618	19041-20000-06535	14248 W OXNARD ST	91401	4	177B153   858	2245018003	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Issued	03/07/2019 12:00:00 AM	ADDRESS	34.17917	-118.44377	Plan check for Title 24 only in existing space Tenant Improvement new lighting in office/reception area, kitchen, bathroom. Total area: 948 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65619	14041-20000-06774	21949 W VENTURA BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	PIN	34.16940578	-118.60503747	Change existing fluorescent light fixtures to LED light fixtures.  Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65620	16041-10000-22746	700 W 7TH ST #S300	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	T-24, PC FOR ENERGY ONLY. T.I. FOR AN EXISTING RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65621	18041-10001-07823	1485 W SUNSET BLVD # J	90026	13	139-5A209 265	5406001017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM			PC Info Complete	05/10/2019 12:00:00 AM	ADDRESS	34.07579	-118.25461	Change to approved set by updating the fault current, AIC bracing and modifying the single line and floor plan. All changes under delta-R4, R5, R6, and delta-3 only. This project is located in the same plan with other 2 projects ( 18041-10001-07828 and 07818).(((REMOVE 2ND FLOOR AND CHANGE OF USE TO A RESTAURANT)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65622	18041-10001-43442	13900 N PICKADILLY PL	91342	7	228B165     7	2582038032	RE11-1-H	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.32549	-118.40593	EXPEDITED PER APPLICANT REQUEST***NEW ROOFTOP SOLAR SYSTEM CONSIST OF 34 MODULES (PANASONIC N330) , 34 OPTIMIZER (SE P400) AND A CENTRAL INVERTER (SE11400H-US).  SYSTEM SIZE IS 11.22KWdc and 11.4KWac.***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65623	18041-20000-28957	5427 MARMION WAY	90042	1	151-5A227 229	5468022017	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	PIN	34.10922421	-118.19694644	Plan check for a PV1 roof-mounted PV system. System size is 2.6 kWdc and consists of (1) 3 kWac rated inverter and (8) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65624	09041-20001-22867	6825 N BAIRD AVE	91335		183B125   941	2126023008	(T)(Q)R3-1		Reseda - West Van Nuys	Reseda			Electrical	Electrical	Apartment			04/13/2011 12:00:00 AM			PC Info Complete	04/18/2011 12:00:00 AM	ADDRESS	34.19463	-118.53759	MODIFICATION TO 0941-20000-22867.  CHANGING LIGHTING FIXTURES FROM APPROVED SET.  TITLE 24 PLAN CHECK ONLY ON 1085 SQFT.  (NEW 20 UNIT APARTMENT BUILDING.   VARIANCE FILED TO SEPERATE FIRE ALARM PLANS.)  Changes are under delt a 1.  The new light wattage still below the allowed wattage.  This for plan check only permit is existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65625	16041-10000-13570	10201 W PICO BLVD	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Issued	06/02/2016 12:00:00 AM	ADDRESS	34.04994	-118.41129	PC FOR POWER. T.I FOR COMMERCIAL BUILDING. MEDIUM VOLTAGE.  UPGRADE OF ONE 25 TO 250A SWITCHBOARD AND REPLACE EXISTING 400A WITH NEW 400. NO LOAD CHANGE OR INCREASE AT THIS TIME. RELOCATION OF DISTRIBUTION EQUIPMENT ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65626	11041-10000-22929	6206 W 87TH ST	90045	11	096B165   761	4123002018	[Q]C2-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM	10/26/2011 12:00:00 AM		Permit Finaled	01/18/2012 12:00:00 AM	ADDRESS	33.95845	-118.39384	3kw roof mounted pv system, one story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65627	18041-10000-00212	20945 W ROSCOE BLVD	91304	3	192B109   680	2779007019	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.22007	-118.58997	Energy plan check for a fire damage remodeling. Scope includes new lighting and equipment. Total area is 2345 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65628	17041-10000-20389	201 W WORLD WAY	90045	11	090B165    62	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	PIN	33.9448278	-118.40237129	PLAN CHECK FOR T24 ONLY FOR CORE & SHELL FOR EXISTING BUILDING. TOTAL CONEECTED LOAD <400A. TOTAL AFFECTED AREA = 7600SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65629	13041-10000-32807	940 W HARRY BRIDGES BLVD GUARD-HOUSE	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	PIN	33.77046453	-118.27163726	PLAN CHECK NEW FIRE ALARM SYSTEM FOR GUARD HOUSE. PORT OF LA  (PART OF TRAPAC TERMINAL PROJECT), with 13 devices, 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65630	09041-10003-17090	5557 E VALLEY BLVD BUILDING-330	90032	14	139-5A237  59	5220032003	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM			PC Approved	03/25/2010 12:00:00 AM	ADDRESS	34.07723	-118.16241	ON THE 3RD FL  OF NEW MANUFACTURING BUILDING CHANGES WERE MADE TO THE EMERGENCY LIGHTING SERVICING THE CORRIDOR: THE EMERGENCY LUMINAIRES WERE CHANGED FROM CEILING-MOUNTED TO WALL-MOUNTED  LAMPS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65631	16041-20002-04268	10635 N OAKDALE AVE	91311	12	207B113   116	2708020031	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.26366	-118.5674	Changes to approved plans.  Change of module type and change of inverter for (1) out of (4): Fronius 10.0-1 to 8.2-1.  New system size 39 kW DC.  Change of routing method through attic.  (((PV1.  Install ground-mounted 40 kW PV system.  (4) Frnonius Primo 10.0-1 inverters with (130) LG315N1C-G4 modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65632	11041-10000-01590	6600 N TOPANGA CANYON BLVD Suite FC10	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	05/19/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	T.I. for Jamba Juice in existing food court space. Electrical plan check for Title 24 and Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65633	16041-20000-36571	14208 W CHAMBERLAIN ST	91340	7	210B153   768	2616011018	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	PIN	34.26968471	-118.44267218	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65634	17041-10001-05266	8464 W MELROSE PL	90069	5	141B173   513	5528017027	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.08341	-118.3755	PC FOR CHANGES TO APPROVED SET. REDUCTION IN GENERAL LIGHTING. PROVIDED OUTLET BOXES ON PLANS TO SHOW LIGHTING THAT IS FOR SALE. THIS IS LIGHTING STORE. LIGHTING FOR SALE EXEMPT FROM T24 REGULATIONS. PERMIT ALREADY ISSUED UNDER MASTER. THIS IS PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65635	17041-10000-32803	6363 W SANTA MONICA BLVD	90038	13	144B185   688	5533008011	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Issued	11/01/2017 12:00:00 AM	ADDRESS	34.09087	-118.32823	Plan check for new Fire Alarm System for new building - System consist of new fire alarm panel and 200 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65636	15041-20000-18845	19207 W VICTORY BLVD BLDG 1	91335	3	180B121   522	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/17/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.18674	-118.55154	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9KW DC.  34-CS6P255 MODULES  AND 1-SMA SB3000US, 1-SMA SB6000US. BUILDING # 1	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65637	13041-10000-21994	6041 W CADILLAC AVE	90034	10	126B173   862	5066002026	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			PC Info Complete	10/01/2013 12:00:00 AM	ADDRESS	34.03806	-118.37594	UPGRADE OF FIRE ALARM SYSTEM IN A MEDICAL FACILITY(KAISER) . 704 TOTAL DEVICES, WITH 1 PANEL. FULLY AUTOMATIC SPRINKLER SYSTEM . 4 STORIES + BASEMENT + ROOF. PROJECT AREA ESTIMATED TO BE AROUND 73000 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65638	17041-20000-24964	6810 N SIMPSON AVE	91605	2	183B169   606	2321018011	RD1.5-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Apartment			07/24/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	02/08/2020 12:00:00 AM	ADDRESS	34.19433	-118.3888	Plan check for energy only. New 3-story 4-unit apartment w/400A service. Plan check outdoor lighting compliance only (>7 parking spaces) - 3,150sqft. Building plan check application #15010-20000-01949.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65639	13041-10000-35994	11341 W COHASSET ST	91352	2	186B173   466	2315016026	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.20675	-118.37839	PV1, Install 3 kW DC roof-mounted solar array for a 2-story house, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3000A-US. (12) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65640	19041-10001-32027	110 E 9TH ST 4TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	Change to an approved set by removing all track lighting on the floor plan, all changes under delta-1 only. (((Energy plan check for a partial office T.I located on the 4th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 13,481-SQ FT )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65641	15041-10000-23079	420 E 3RD ST	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	01/06/2016 12:00:00 AM	ADDRESS	34.04686	-118.24182	SERVICE UPGRADE TO AN EXISTING BUILDING. 2000A ALL LOADS TO BE FUTURE. PC FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65642	17041-10000-45098	3501 W SAN FERNANDO ROAD	90065	13	156B209   332	5458004025	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.1204	-118.25105	REPLACE INDOOR & OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65643	11041-20000-00387	17828 W CHATSWORTH ST	91344	12	207B129   452	2733005005	C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	01/07/2011 12:00:00 AM		Permit Finaled	01/28/2011 12:00:00 AM	ADDRESS	34.26466	-118.52259	energy plan check bakery	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65644	19041-20000-51344	3410 N WONDER VIEW DR	90068	4	159B181   652	5577001007	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.12974	-118.34027	PV1.  Install 8.19 kW roof mounted PV system with 40.5 kWh energy storage system.  (26) modules with 7.6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65645	16041-20000-16080	3709 S TROUSDALE PKWY 1ST FLR	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.01851	-118.28672	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 1201.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65646	15041-10000-05479	3901 W 6TH ST	90020	10	135B193   861	5503019010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.06364	-118.30808	CHANGE USE OF EXIST RETAIL SPACE TO RESTAURANT USE AND COMBINE WITH ADJACENT EXIST RESTAURANT SPACE TO CREATE A LARGER RESTAURANT USE.  (N) OUTDOOR DINING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65647	12041-10000-15945	2915 N CORDA LANE	90049	11	156B137    57	4490006039	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.12618	-118.48856	New rooftop 11.28kw photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65648	19041-10000-48801	4450 W ADAMS BLVD	90016	10	123B185   736	5050001009	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	04/15/2020 12:00:00 AM		Permit Finaled	08/28/2020 12:00:00 AM	ADDRESS	34.03237	-118.33658	PC (core and shell) for installing a 600A ,240/120V, 3ph. for a retail.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65649	17041-20000-37577	8755 W YATES ST	91040	7	204B189   414	2546002019	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM			Reviewed by Supervisor	10/25/2017 12:00:00 AM	ADDRESS	34.25675	-118.32433	Plan check for solar pv system (roof-mounted array) with AC coupled battery battery backup system on SFD.5kW unground pv system. (20) 300W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65650	15041-10000-41087	132 N SWALL DR 1-14	90048	5	138B169   260	4335001007	R3-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			12/07/2015 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Closed	10/19/2017 12:00:00 AM	ADDRESS	34.07622	-118.38569	NEW APARTMENT BUILDING 800 AMP SERVICE.  FULL PLAN CHECK.  FIRE VARIANCE TO FILE AT LATER TIME.BUILDING APPL# 15041-30000-00764	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65651	19041-10000-20165	17048 W GRESHAM ST	91325	12	195B133   402	2690010013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.22959	-118.50432	PV1, PC FOR NEW ROOFTOP 10.4 KW SYSTEM. SYSTEM CONSISTS OF 32 MODULES(PANASONIC VBHN325KA03) WITH 32 OPTIMIZERS (SOLAREDGE P400). 1 CENTRAL INVERTER(SOLAREDGE SE1000H-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65652	17041-10000-16364	2478 W WASHINGTON BLVD	90018	10	126B189   936	5073025023	C2-1VL-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.02	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			Reviewed by Supervisor	06/13/2017 12:00:00 AM	ADDRESS	34.03971	-118.317	PC for power and energy for store TI in methane zone. Scope includes adding a new 600 A service, equipment and two new panelboards and two transformers. Total areas 14356 sqft.Building # 17016-10000-12875	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65653	15041-10002-35402	1362 N WESTERN AVE	90027	13	147A193   205	5544032013	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.09614	-118.30905	12/16/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include revising fault current values due to available fault current starting at the 5000A DWP switchboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65654	19041-10000-42995	10545 W MAHONEY DR	91040	7	207B177    89	2528033015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Issued	01/14/2020 12:00:00 AM	ADDRESS	34.26338	-118.35974	[E-Plan] NEW PV1 ROOF-MOUNT INSTALLATION FOR AN EXISTING SERVICE (CENTER-FED) OF 200 AMPS  WITH 1 LOAD CENTER OF 125 AMPS, 12 MODULES (SLA-M MONOCRYSTALLINE). 1 INVERTER (SE7600A-US), 1 OPTIMIZER (P320). 1 ESS (RESU10H), AND 1 AUTO-TRANSFORMER (SEAUTO-TX-5000). PV SYSTEM SIZE: 3.84kW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65655	15041-20000-28158	6215 W DEL VALLE DR	90048	5	132B177    81	5088016031	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Expired	09/27/2017 12:00:00 AM	ADDRESS	34.06134	-118.36418	PV1 ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE 860 WATTS. (4) MODULES-SOLAR WORLD 250WATTS(4) MICROINVERTERS- ENPHASE 215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65656	19041-20000-44194	10040 N OLD DEPOT PLAZA ROAD	91311	12	204B105   811	2747010***	PF-1XL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.25287	-118.59878	PLAN CHECK FOR INSTALLING A NEW 3000A SERVICE, 3000A SWITCHBOARD, AND (2) 660 KVA EV CHARGERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65657	17041-10002-32951	11844 W FOOTHILL BLVD	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM			PC Approved	07/11/2018 12:00:00 AM	ADDRESS	34.27365	-118.39446	[[PLANCHECK ONLY. CHANGES TO APPROVED SET. CHANGES ARE CLOUDED.]]PC FOR FIRST TIME TENANT FOR RETAIL SPACE FOR SEVEN ELEVEN STORESCOPE INCLUDES NEW PANELS CIRCUITS EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 2881 SQ.FT.   B#17016-10000-26369	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65658	15041-10000-43026	6201 W HOLLYWOOD BLVD Ground-Floor	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	PC for T-24, energy only to a mix used building, retail and apartment. Scope is being done in the ground floor (retail). Adding new lighting and power. Total Sq ft = 976.27	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65659	16041-10000-22061	704 S MATEO ST	90021	14	124-5A217 257	5166015006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.03422	-118.23214	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT AND CHANGE OF EXISTING RETAIL TO NAIL SALON WITH ACCESSORY JUICE BAR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1454 SQ. FT. B#16016-10000-08491	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65660	14041-10000-10237	1719 W 253RD ST	90717	15	036B193   998	7410015***	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	33.79495	-118.30841	PV1.Install 4.5 kW DC roof-mounted solar array on a 2 story-house, interconnect with main service panel.(1) Transformerless inverter: POWER-ONE # AURORA PVI-3.6-OUTD-S-US-Z-A(18) Modules: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65661	15041-10000-27106	12452 W OSPREY LANE Unit #2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	PV2 installed roof mounted pv system for UNIT #2. Size 3KW, interconnected with the main service panel.(8)modules: SPR-230NE-BLK-D(1)PVI 3.0-OUTD-S-US inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65662	13041-10000-15851	9947 N MARCUS AVE	91042	7	202-5A201 337	2568015031	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	Apartment			06/17/2013 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.24914	-118.282	New 9 unit two-story apartment building.  Power and energy plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65663	18041-10000-37740	22050 W VENTURA BLVD	91364	3	171B101   153	2169002032	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1374.01	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.16834	-118.60765	Replacing existing outdoor lighting with new LED fixtures. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65664	15041-10000-33380	300 S GRAND AVE 1ST FLR	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Approved	10/08/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	T-24, TI TO AN ELEVATOR LOBBY ON AN (E) HIGH RISE BUILDING. SCOPE INCLUDES NEW  LIGHTING AND POWER. PC FOR ENERGY ONLY. TOTAL SQ. FT. 2011. ***INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT# 15041-10000-31119. (PC ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65665	13041-10004-07125	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			08/11/2015 12:00:00 AM			Reviewed by Supervisor	08/24/2015 12:00:00 AM	ADDRESS	34.04594	-118.25757	Change to approved set under field request; All changes are under delta-9 and within the description of the narative letter only.(((7-STORY MIXED USED BUILDING 700 UNIT APARMENT, OVER 2-LEVEL SUBTERRANEAN GARAGE :  upper 6 levels residential and retail/gym on the 1st floor. None highrise.. 5000A SERVICE;__this note : by Nabil, this methane zone.  was indicated the level changed from 5 to 2.  see plan number 12041-10000-29828))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65666	16041-20000-15656	7800 N AIRPORT BUSINESS PARK WAY STE A	91406	6	189B137   126	2205009095	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.21143	-118.49524	PLANCHECK FOR T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. STE A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65667	18041-10000-31761	10250 W SANTA MONICA BLVD 2850	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Issued	09/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR POWER AND NERGY FOR TENANT CORE & SHELL - Interior alteration to existing space in preparation for future tenant T.I. including wall finish, ceiling grid, new closet room. TOTAL AFFECTED AREA = 1474 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65668	18041-10000-42811	6075 W HARGIS ST Lot C	90034	10	123B173   898	5065005019	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.0326	-118.37653	"NEW ROOFMOUNTED 2.2KW PV SYSTEM WITH 7 MODULES ON SINGLE FAMILY HOUSE. Lot ""C""BLD#16010-10000-05440"	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65669	18041-10000-12767	12000 W IDAHO AVE 1-8	90025	11	126B145   893	4259003006	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			04/09/2018 12:00:00 AM			Corrections Issued	04/09/2018 12:00:00 AM	ADDRESS	34.03918	-118.46049	PC FOR POWER ONLY, SCOPE OF WORK INCLUDES REPLACEMENT OF INVERTER TO A 20KW GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65670	16041-20000-44969	418 N NORTH FARING ROAD	90077	5	141B157    12	4358007015	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			Reviewed by Supervisor	01/25/2017 12:00:00 AM	ADDRESS	34.08616	-118.43257	Plan check for power. (N) One story accessory living quarter for pool use and pool equipment at north side of the property(Accessory Building#6).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65671	11041-10000-19251	6701 N ETON AVE	91303	3	180B105    27	2148030035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.19217	-118.59564	NEW 6-LEVEL (W/ ATOP ROOF PKG) OPEN PKG STRUCTURE ATTACHED TO 298-UNIT APT COMPLEX. See permit #11010-10000-00563 for separate apartment building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65672	19041-30000-16380	2029 S CENTURY PARK EAST Ste 1700N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Issued	05/02/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is an existing tenant suite on the 17th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 6,127 sq. ft.Note: Building permit has been issued under 19016-10000-02973	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65673	19041-10000-53821	650 W 23RD ST	90007	1	123A203   146	5124028001	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	10/08/2020 12:00:00 AM	ADDRESS	34.03136	-118.27574	Scope of work includes new fire alarm system containing 61 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65674	17041-10001-24712	1259 W FLORENCE AVE	90044	8	102B197  1150	6014034030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2017 12:00:00 AM			PC Approved	09/11/2017 12:00:00 AM	ADDRESS	33.97475	-118.29784	Supplemental PC for relocation of RPS, inveter, disconnect.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65675	14041-20000-05479	6355 W BLANCHARD CANYON ROAD	91042	7	204A205    16	2569019053	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.25459	-118.27006	Roof mounted PV system with 8.25KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65676	10041-20000-16538	4640 N LANKERSHIM BLVD #305	91602	4	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	09/16/2010 12:00:00 AM	ADDRESS	34.15499	-118.36841	Plan check T-24 Energy TI for office space #305. Existing light fixtures and circuits. Relocate fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65677	17041-10000-09063	380 WORLD WAY TBIT-SWA	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Title 24 only tenant improvement of existing space (for southwest air) at TBIT, Bradley West, North Concourse (N4, L3) including new office partitions and convert e. office space to a break room. Total area: 3295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65678	14041-20000-23240	7325 N ENFIELD AVE	91335	3	186B129  1055	2121005006	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.20373	-118.52424	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER WITH STANDARD PLAN. SYSTEM USES POWER OPTIMIZERS. TOTAL OF 24 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65679	18041-10000-10622	10960 W MOORPARK ST	91602	4	165B173   388	2423014029	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Closed	05/18/2023 12:00:00 AM	ADDRESS	34.15023	-118.36985	Plan check for Title 24 only remove HID fixtures and replace with new LED fixtures outdoor lighting. Totala area: 5,100 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65680	13041-10000-02037	14401 W CLYMER ST	91345	7	207B149   392	2617010007	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2013 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.26458	-118.44654	photovoltaic system for single story single family dwelling. total system size of 9.156 kw. using pnaels sinpower spr-327-wht-d. central inverter sunpower spr-8000m. transformed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65681	16041-10001-34768	1664 W WASHINGTON BLVD	90007	1	126B197   712	5075036008	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM			PC Approved	02/25/2019 12:00:00 AM	ADDRESS	34.03979	-118.29354	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS CHANGES INCLUDE UPDATING SERVICE ENTRACE CONDUCTORS FROM COPPER TO ALUMINUM, SEAL OFF RE-SIZED, AND UPDATING FAULT CURRENT ON THE SINGLE LINE DIAGRAM. ALL CHANGES UNDER DELTA-1 ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65682	14041-20000-04143	10166 N CASABA AVE PV1	91311	12	204B113   324	2741007008	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.2557	-118.57596	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PNL. UNGROUNDED SYSTEM, SIZED @ 3.5 kW DC, WITH (14) CANADIAN SOLAR #CS6P-250PX,  (14) OP300 OPTIMIZERS, (1) SOLAREDGE SE3000-US-ZB-U.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65683	15041-20000-34840	3809-3811 S GRAND VIEW BLVD	90066	11	114B157  1475	4235023001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.00441	-118.43106	TI to an existing office located in 1 story build. Total area: 1152 sq. ft.(indoor+outdoor) PC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65684	13041-20000-24141	19602 W CITRUS RIDGE DR	91356	3	171B117   572	2175040004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM			PC Approved	09/04/2013 12:00:00 AM	ADDRESS	34.16219	-118.56065	Changes to previously approved set of plans. Change to AC disconnect. Plan check only. Original permit on 13041-20000-14071. PV1 FOR 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 13.230 KWDC. 54 MODULES 2 INVERTERS WITH 1 SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65685	19041-20000-02258	12563 N BYRON AVE	91344	12	219B133   240	2608008003	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.29875	-118.51031	Plan check for a PV1 roof-mounted PV system. System size is 8.28 kWdc/7.532 kWac-CEC and consists of (23) modules, (23) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65686	14041-20000-23005	4546 N STROHM AVE	91602	4	168B177   964	2420034001	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.15354	-118.35901	Standard plan: 7.6KW PV1 roof-mounted system including: (34) Sunpower SPR-E20-245  modules and (2) SMA SB3800TL  inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65687	17041-20000-21586	9841 N AIRPORT BLVD 12th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Info Complete	06/27/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building.  adding new lighting new controls to existing panels in  a restroom on the 12th floor.  plan check for energy only.permit fees paid under application number 17041-30000-20690this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65688	14041-10000-25561	2403 W 4TH ST	90057	1	135A203   203	5154035032	R3-1	Central	Westlake		YES	2088.02	Electrical	Electrical	Apartment			09/17/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.06409	-118.27662	Methane hazard mitigation system for a new 3 story apartment.  Active system.  52 sensors, 48 horn strobes, and 1 controll panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65689	16041-20000-01418	8215 N VAN NUYS BLVD #100, 106	91402	6	192B149   484	2210010023	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	04/05/2016 12:00:00 AM	ADDRESS	34.22037	-118.44896	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area =3,761 sq. ft.Note: Building permit has been pulled under 16016-20000-00634	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65690	18041-10000-06291	3183 W WILSHIRE BLVD STE 199	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.06196	-118.29111	PC for T24 only for replacement of existing lights to LED. Total area 4059sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65691	14041-20000-09948	9741 N INDEPENDENCE AVE	91311	12	201B105   140	2746003018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.247	-118.59099	TI in an existing commercial building.  Plan Check for T-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65692	13041-10000-04663	14006 W RIVERSIDE DR 260	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	Permit for branch circuits was already pulled under application # 13041-20000-03937.  This application was for T24 plan check only for new LED lighting fixture D.  Applicant submitted revised set of approved T24 plans(12041-10000-FILL IN) (changed lighting fixture schedule) without original approved set, so started a new OTC plan check.  (Original application description: T24.TI TO EXISTING RETAIL FOR NEW KIEHLS STORE. 1126SF space 260)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65693	18041-20000-47758	10634 W ART ST pv1	91040	7	201B177   209	2542020013	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.24844	-118.36162	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65694	17041-10000-05972	19860 W NORDHOFF PL	91311	12	198B113   155	2761001812	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.23578	-118.56623	Plan check for Title 24 only in existing space, replace Indoor existing lighting fixtures with LED fixtures. Total area: 8,100 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65695	14041-20000-29455	800 W WILSHIRE BLVD 2nd Fl	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			PC Approved	10/23/2014 12:00:00 AM	ADDRESS	34.0493	-118.25841	T.I. to existing high rise building on the 2nd floor in the elevator lobby.  Install general/emergency lighting.  All exit signs are existing.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65696	13041-20000-33993	601 S FIGUEROA ST SUITE 2250	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.05076	-118.25881	PC FOR T24 ENERGY ONLY. TOTAL AREA 350. SUITE 2250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65697	16041-30001-42255	700 W WILSHIRE BLVD Suite B	90017	14	129A209    65	5144006020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM			PC Approved	06/15/2017 12:00:00 AM	ADDRESS	34.04863	-118.25733	06/15/2017Changes to an approved set of plans note changes on delta 6 and 7__________________Note: Building application has been generated under 16016-30000-28764	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65698	18041-20000-02908	15733 W FORGE PL	91344	12	207B141   470	2661002005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.26389	-118.47496	pv1install roof mounted pv system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65699	17041-20000-46341	8501 N FALLBROOK AVE STE #225	91304	12	192B097   587	2005022006	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Issued	12/27/2017 12:00:00 AM	ADDRESS	34.22478	-118.62651	Plan check for energy only. TI to existing 2nd floor office. New lighting (incl. emergency) - 12,387sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65700	15041-10001-18231	949 S FIGUEROA ST	90015	14	127-5A207   6	5138003014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM			PC Approved	07/17/2015 12:00:00 AM	ADDRESS	34.04527	-118.26392	Plan check for energy per inspector notice for permit 15041-10000-18231.  (((INSTALL OUTLET, SWITCHES & LIGHTS.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65701	19041-10000-36975	717 N ORLANDO AVE	90069	5	141B173   365	5528002027	R1-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			09/16/2019 12:00:00 AM	09/18/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.08427	-118.37343	T-24 PLAN CHECK FOR A TI TO THE PARKING LOT AND HALLWAYS. REPLACING ALL LIGHTING TO LED. SCOPE INCLUDES NEW LIGHTING AND CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65702	19041-10000-13401	13130 W BURBANK BLVD	91401	4	174B157  1137	2345005028	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.17191	-118.41936	Plan check for title 24 only . Replace fluorescent troffers with new led retrofit kits. Indoor. Building 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65703	16041-10000-01493	3526 N MARMION WAY	90065	1	144A223   355	5446025013	[T][Q]CM-1VL	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1990.00	Electrical	Electrical	Apartment			01/14/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.08726	-118.21354	PC FOR A NEW FIRE ALARM SYSTEM TO A NEW 4 STORY 49 UNIT APARTMENT BUILDING OVER ONE LEVEL SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES 1 FIRE ALARM PANEL, 1 COMMUNICATION PANEL, AND 177 FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65704	16041-10000-44956	1216 S SANTEE ST	90015	14	124-5A209 136	5145027039	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.03573	-118.25761	PC for energy only; Indoor + Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 43,750.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65705	13041-10000-21876	20961 W KNAPP ST	91311	12	198B109   106	2746009021	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.23854	-118.58973	Replacement of existing fire alarm control panel due to malfunction.  New fire alarm devices to be compatible with new FACP.  Single story manufacturing building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65706	15041-10002-03206	724 S SPRING ST Unit 202-204	90014	14	127-5A211 131	5144015041	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM			PC Approved	01/26/2016 12:00:00 AM	ADDRESS	34.04384	-118.25268	1/26/16Inverter from 24000 VA changed to 500 VA corresponding pages are signed by Plan check engineer Mehdi Zandi. (((TENANT IMPROVEMENT/CHANGE OF USE FROM OFFICE TO DANCE STUDIO IN A COMMERCIAL HIGH RISE BUILDING. TOTAL AREA 3188 SQ FT.  PC FOR POWER AND ENERGY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65707	15041-20002-41807	837 S HARVARD BLVD	90005	10	132B193   774	5093017019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Apartment			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.05675	-118.30436	[[1/16/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 3 CHANGES CLOUDED. ADDING A SECOND DOORTO MEET 110.26(c)1,2 AND ADDING LIGHTS TO THE DRIVEWAY + T24]]]]11/15/17changes to an approved set of plans.  changes noted delta 2.  changes include revised electrical room. this is plan check only.(((Full pc for a New 6 story, 65 unit 5 level apartment building over a 2 level subterranean garage. Total area is 50359 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65708	19041-20000-47432	727 N LINDA FLORA DR	90049	5	138B145     8	4368022007	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	ADDRESS	34.07881	-118.46571	PLAN CHECK FOR POWER SERVICE UPGRADE TO A 600 AMP SINGLE PHASE. NO NEW LOADS ADDED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65709	12041-20001-16885	4400 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.00, 1953.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	12/06/2012 12:00:00 AM	ADDRESS	34.09662	-118.28529	Modification of perviously approved plans for new installation of new sprinkler monitoring system.  Permit fee for 10 additional devices is under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65710	17041-10001-02854	160 N GLENDALE BLVD	90026	1	135A209   280	5160013011	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM			PC Approved	07/05/2018 12:00:00 AM	ADDRESS	34.06352	-118.25967	06/25/2018Changes to an approved set of plans; plancheck only. Note changes on delta 2 only. Changes include the addition of circuits, panels, load calculations and t-24 forms. ____________Plan check for power and energy for office T.I. install equipment rated at 600A.  Total area: 17,075 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65711	12041-20001-28235	5160 N VINELAND AVE 101B-101C	91601	4	171B173  1378	2419001042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.16418	-118.37009	T24 lighting plan check for change to lighting in an existing retail space.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65712	11041-10000-08925	11857 W SANTA MONICA BLVD	90025	11	126B145   385	4263032033	(T)(Q)RAS4-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/03/2011 12:00:00 AM			PC Approved	05/03/2011 12:00:00 AM	ADDRESS	34.04239	-118.45956	TI TO AN EXISTING SINGLE STORY OFFICE BUILDING.  OTC PLAN CHECK, T-24 WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65713	13041-10001-21148	12652 W VILLAGE LANE bldg #2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/09/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Issued	11/09/2016 12:00:00 AM	ADDRESS	33.97757	-118.41475	11/09/16Changes to an approved set of plans. All changes are made under delta 5. Changes include revising battery calculation due to a cellular back-up device being added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65714	16041-20000-05132	22601 W SANTA SUSANA PASS ROAD	91311	12	210B101    11	2723002018	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Expired	06/06/2018 12:00:00 AM	ADDRESS	34.27227	-118.6163	PV2.  GROUNDMOUNTED SOLAR SYSTEM. CARPORT. SYSTEM SIZE: 400KW. 1292 MODULES11 INVERTERSFIRE APPROVAL NOT REQUIRED PER APPLICANT.BUILDING PLANCHECK : 16010-20000-01475	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65715	18041-10000-15804	1035 N SWARTHMORE AVE #2-105	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.04825	-118.52512	"PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. JEN MEYER RETAIL.  418 SQFT. UNIT #2-105BUILDING PERMIT : 18016-10000-13331INTERIOR REMODEL TO EXISTING RETAIL SPACE ""JENNIFER MEYER"" WITHIN PACIFIC PALISADES VILLAGE. SCOPE INCLUDE NEW INTERIOR NON BEARING PARTITION, NEW DROP CEILING PER ENGINEER DESIGN, FINISHES, MILLWORKS AND FLOORING."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65716	10041-10000-05756	19801 W NORDHOFF PL #108	91311	12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	05/12/2010 12:00:00 AM	ADDRESS	34.23568	-118.56464	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR CHANGE OF USE FROM PORTION OF EXISTING WAREHOUSE INTO OFFICE. TENANT IMPROVEMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65717	16041-10001-16012	1515 S GRANVILLE AVE	90025	11	126B149   487	4262005023	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			10/19/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	PIN	34.04222127	-118.45848597	PC FOR LOST SET OF PLANS WITH ADDITIONAL ON SITE REVISIONS UNDER DELTA 2.NEW REVISIONS INCLUDES NEW CIRCUITS AND ADDITIONAL EQUIPMENT PANEL AND TRANSFORMER.NEW MIXED USED APARTMENT BUILDING 147 UNIT 5 STORIE .PLAN CHECK FOR POWER AND ENERGY. 12 TYPICAL UNITS, 6 LOFTS AND 3 LIVEWORK UNITS. WITH TOTAL AREA OF 1927884 SQFT. NOTE FIRE ALARM VARIANCE IS FILLED TOGETHER. BUILDING APPLICATION NUMBER 14041-10000-03747.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65718	18041-20000-05446	14724 W VENTURA BLVD	91403	4	166-5A149  63	2276003036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	01/09/2020 12:00:00 AM		Issued	01/09/2020 12:00:00 AM	ADDRESS	34.15162	-118.45395	T24 plan check energy only, facade lighting only.  plan check for outdoor t-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65719	17016-10000-17927	221 N FIGUEROA ST	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	04/13/2018 12:00:00 AM		Issued	04/13/2018 12:00:00 AM	ADDRESS	34.05882	-118.25099	Test permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65720	14041-10000-34779	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Closed	11/30/2017 12:00:00 AM	ADDRESS	33.93845	-118.42964	pLAN CEHCK FOR TEMPORARY CRUSHER AT lAX, PLAN CHECK FOR SERVICE/BOARD  FEEDING CRUSHERS WAS APPROVED UNDER 13041-10000-32206.  CRUSHER IS INSTALLED FOR PERIOD OF TIME ( 6 MONTHS TO 1 YEAR).  CRUSHER TO BE HANDEL UNDER SPECIAL EQUIPMENT INSP3ECTION PER INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65721	16041-10000-21831	3921 N LAUREL CANYON BLVD	91604	2	162B165   437	2369013019	R1-1-RFA-RIO, R1-1VL-RFA-RIO, [Q]RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.14179	-118.39477	Install New Fire Alarm system,   (5) FA Panels    (71) FA devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65722	13041-20000-34675	20957 W INGOMAR ST	91304	3	189B109   825	2109016020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.21205	-118.59055	New rooftop PV system for an existing sfd.  System uses Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65723	13041-10000-04232	111 E UNIVERSAL HOLLYWOOD DR # 2630	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM			PC Approved	02/19/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING OF OFFICES/CONFERENCE ROOM IN SUITE 2630PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65724	19041-20000-44761	20929 W VENTURA BLVD #12	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Issued	03/03/2020 12:00:00 AM	ADDRESS	34.16667	-118.58906	Plan check for power and energy for new lighting and electrical equipment. Total area: 1376 sq ft. *****************************************************Work description per building appliation: 19016-20000-35207FIRST TIME TENANT R. I. AND CHE OF USE FROM RETAIL TO NEW NON-MEDICAL THERAPY**********************************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65725	14041-10000-19956	5530 E VALLEY BLVD	90032	14	138A237    30	5221013038	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.07423	-118.16225	PC FOR POWER AND ENERGY. NEW 7 ELEVEN WITH A RETAIL STORE 14010-10000-02403:DISPENSERS AND CANOPY UNDER APPLICATION 14041-10000-32528ESTIMATION OF THE # OF DEVICES PER APPLICANT REQUEST AND ADDING THE MISSING PANELS DUE TO UNSHOWN PANEL SCHDEULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65726	17041-20001-45056	17068 W KNAPP ST	91325	12	198B133   411	2692020044	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM			PC Approved	01/04/2018 12:00:00 AM	ADDRESS	34.23825	-118.50515	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.Interconnecting with center-fed panel.7.6kW ungrounded system. (26) 330W pv modules.Each module has a 370W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65727	10041-20000-02461	12744 N SAN FERNANDO ROAD Bldg #4	91342	7	222B145   396	2506003010	M2-1	North Valley				1065.10	Electrical	Electrical	Commercial			02/11/2010 12:00:00 AM	07/23/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.30155	-118.46112	Tenant improvement in building #4: new solvent recovery system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65728	15041-20000-21048	12408 W SANTA MONICA BLVD	90025	11	126B145   928	4267031004	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.03883	-118.46681	Plan check for power and lighting. Project site is an existing commercial building. Project scope is a fire rebuild. Work includes a new 600 amp service, (5) panels, and associated loads. Total lighting area = 5,695 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65729	10041-20000-04220	1400 N GAFFEY ST	90731	15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	05/27/2010 12:00:00 AM	ADDRESS	33.75723	-118.29183	OUT DOOR LIGHTING FOR PARKING SPACE. THIS P/C IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65730	18041-10000-45893	9410 N TOPANGA CANYON BLVD	91311	12	198B101   334	2746013038	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.2412	-118.60593	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65731	14041-20000-34876	3410 N LA SOMBRA DR	90068	4	159B181   402	5579025005	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.13151	-118.34095	Permit fee is $0.00 due to 2012 CA State Senate Bill 1222.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters and (53) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65732	12041-20000-11229	16100 W VENTURA BLVD #140	91436	5	168B141   983	2284003048	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	05/18/2012 12:00:00 AM		Issued	05/18/2012 12:00:00 AM	ADDRESS	34.15617	-118.48407	T-24 lighting and emergency plan check for suite 140.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65733	15041-20001-15261	171 N FULLER AVE	90036	5	138B181   502	5512014004	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	34.07559	-118.34994	Expedite per applicant request[[[[Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65734	19041-20000-45044	17611 W HIDDEN OAKS RD	91316	5	168B129   551	2290015016	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	PIN	34.15553827	-118.51687808	PV1.  Install 34.560 kW DC / 30.506 kW AC roof mounted grid tied PV system.  (96) modules with microinverters. $0 permit fees due per senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65735	18041-20000-35464	12632 W SUNSET BLVD	90049	11	132B141   565	4405028017	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			Reviewed by Supervisor	09/27/2018 12:00:00 AM	ADDRESS	34.05702	-118.48405	Plan check for PV roof mounted system, system size: 13.96kW AC with 46 PV modules and 46 Microinverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65736	18041-20004-22671	13060 W ROSCOE BLVD	91352	2	192B161   102	2304005023	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.2215	-118.41867	01-08-2019 Changes to an approved set of plan. Changes include  roof modules layout, addition of  Electrical Gutter Box, and update source circuit from junction box to inverter length, update conductor size from PV Distrbt Panel to AC Disconnet.  Changes apply to clouded area only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65737	17041-10000-46639	714 W OLYMPIC BLVD #800	90015	14	127-5A207  70	5138012002	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.04454	-118.26341	Plan check for Title 24 only in existing space. T.I. Suite 800 in high rise building. Total area: 5257 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65738	17041-20000-34139	14315 W JOY DR	91331	6	198B153  1027	2644027239	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24174	-118.44502	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65739	14041-20003-06440	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Changes to approved set: New 3000A service equipment to replace existing service equipment.  Note: Proposed future distribution equipment in electrical room #6 to trigger additional egress door and panic bar equipment for working space around large equipment.  ((change to previuosly approved set of plans. changes covered under delta 12 clouded. ))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65740	10041-10000-12480	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM			Reviewed by Supervisor	07/30/2010 12:00:00 AM	ADDRESS	34.20103	-118.38536	Installing a new UPS for a medical office building. Plan check for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65741	15041-10000-13301	1021 N HOOVER ST 1-76	90029	13	144A201    36	5539001025	CM-1VL	Central	Hollywood	East Hollywood		1914.10	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM			PC Approved	05/04/2015 12:00:00 AM	ADDRESS	34.09043	-118.2849	IN THE COMMON AREA OF A APT BLDG, AN OFFICE ADDITIONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65742	16041-20001-08947	17736 W COMMUNITY ST	91325	12	192B129   246	2787009015	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM			Reviewed by Supervisor	03/30/2016 12:00:00 AM	ADDRESS	34.22265	-118.52068	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 16.4 kWac and consists of (2) inverters, (70) modules, (1) load center, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65743	10041-10000-19874	2472 E 8TH ST	90021	14	123A219     1	5166001813	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Public Safety Only			10/06/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Expired	12/09/2015 12:00:00 AM	ADDRESS	34.02945	-118.22736	Installation of a fire warning system in the Amtrak maintenance facility bldg	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65744	17041-10000-44524	1933 S ALAMEDA ST	90058	9	118-5A215  43	5167013026	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.01901	-118.23979	Remove HID fixtures and replace with new LED fixtures  T-24 only.TOTAL SQ.FT 15600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65745	14041-10001-13184	7448 N MILWOOD AVE	91303	3	186B105   426	2112010006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.21	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.206	-118.59415	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL A 11.55 KW DC ROOF-MOUNTED SOLAR ARRAY. INTERCONNECT WITH SERVICE PANEL. TRANSFORMERED.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65746	19041-20000-28963	6629 N LEMP AVE 1-3	91606	2	180B169   464	2320025016	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1232.05	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.1912	-118.38487	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING COMMECERIAL BUILDING. SYSTEM SIZE IS 5.1KW DC/4.65 KW AC CEC. SCOPE OF WORK INCLUDES (17) PV MODULES WITH P320 OPTIMIZERS, A SE5000H INVERTER, AND A 125A SUB PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65747	17041-20003-24365	13310 N DE FOE AVE	91342	7	225B145   455	2501022064	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.31322	-118.46088	02/08/2018 Changes have been made to the work description. Work description shall now read: pv1. install roof mounted pv system sized 10.5kw interconnected with msp.*****Previous Work Description*****pv1install roof mounted pv system sized 10.3kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65748	15041-20001-20622	19566 W VENTURA BLVD	91356	3	174B117   324	2164016027	C2-1VLD, P-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM			PC Approved	07/27/2015 12:00:00 AM	PIN	34.17217845	-118.55930747	07/27/2015 Changes to an approved set of plans. Changes have been made to the lighting floor plan to reflect field changes. Changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check Title 24 only for Beauty Salon. Existing branch circuits. Total indoor lighting area: 1,066 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65749	16041-20000-10386	13928 N BALBOA BLVD	91342	7	228B137   219	2603025027	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.32344	-118.49127	Fire alarm plan check only. Add new RPS to existing FA panel in commercial building. New RPS supplies 5 new devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65750	16041-20000-15649	20618 W COHASSET ST	91306	3	186B109   470	2113005017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Expired	06/06/2018 12:00:00 AM	ADDRESS	34.20644	-118.5825	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65751	19041-20000-37849	21600 W OXNARD ST SUITE 600	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 Energy only in existing office Tenant improvemet. Total area: 1016 sq ft. B#19016-40000-28306	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65752	19041-30000-14843	900 N WILCOX AVE	90038	13	144B185  1195	5533021038	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.08728	-118.33077	Plan check for a fire alarm system for a 4-story, 17-unit apartment building. Fire alarm consists of (1) FACP and (94) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65753	12041-20000-30775	22622 W VANOWEN ST	91307	3	180B097    33	2038020063	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	Commercial			12/26/2012 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.19355	-118.61959	Electrical and energy for a remodel of A PRIVATE  HIGH SCHOOL BUILDING WITH CLASSROOMS, ADMIN. OFFICES AND OTHER ACADEMIC SUPPORT SPACES.  *****BUILDING IS FULLY SPRINKLERED****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65754	17041-10000-09238	10337 N HILLVIEW AVE	91311	12	204B105   170	2722016009	R1-2	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.25844	-118.60294	Plan check for PV roof mounted system System size: 1.25kW with 8 modules and 8 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65755	13041-20000-35453	6922 N ALDEA AVE	91406	6	183B133   690	2230002004	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Expired	02/16/2016 12:00:00 AM	ADDRESS	34.1963	-118.50824	PV1 TRANSFORMERLESS SYSTEM. SOLAR OPTIMIZER USED. TOTAL SYSTEM SIZE 5KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65756	15041-10000-09003	920 S CROCKER ST 104	90021	14	124-5A211 152	5132002045	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			PC Approved	03/31/2015 12:00:00 AM	ADDRESS	34.03569	-118.24958	Energy plan check for a retail T.I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65757	19041-10000-31468	1855 N DILLON ST	90026	13	145-5A205 137	5431028006	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.09366	-118.26969	[EPLAN] PLAN CHECK FOR ESS(SONNEN BATERY-GEN3.1-ECO12.5) CONNECTED TO EXISTING PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65758	17041-10000-19514	11919 N BROMONT AVE	91331	7	216B161   459	2527009027	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.28638	-118.4116	PC for rooftop solar. PC for 17 new AXITEC AXIPOWER AC-265P with one 3.8KW Fronius Primo.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65759	15041-10000-24207	9110 N VAN NUYS BLVD	91402	6	198B149   535	2639008025	[Q]C2-1VL, [T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.23602	-118.45005	NEW FIRE ALARM SYSTEM WITH (33) DEVICES , ONE CONTROL PANEL , AND ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65760	13041-10001-34478	23938 W OXNARD ST	91367	3	177B089   619	2045017023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	05/09/2014 12:00:00 AM	ADDRESS	34.1796	-118.64856	Expedited RSES plan check per applicant request.{{PV1, Install a 10.5 kw DC roof-mounted solar array system interconnect with main service panel with (2) transformerless inverter(s)[SOLAREDGE # SE3800A-US and SOLAREDGE # SE6000A-US] and (42) modules[AU OPtronics # PM245P01_250W] for 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65761	17041-10000-21812	3784 S NORMANDIE AVE	90007	8	117B197   368	5037013001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.01787	-118.3	PC FOR T24 ENERGY ONLY, REPLACE LIGHTS WITH LED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65762	15041-20001-16280	936 S OLIVE ST UNIT 257	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #6 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65763	13041-10000-18763	1551 W SHATTO ST	90017	1	132A205   552	5142028031	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	03/27/2015 12:00:00 AM	ADDRESS	34.05615	-118.2693	CHANGE OF USE FROM (E) OFFICE SCHOOL EMPLYMENT CENTER TO PUBLIC SPA/RESTAURANT ON 3RD FLOOR AND CONVERT PORTION OF (E) GARAGE ON 1ND FLOOR;3-stories buildingmost of the 1st fl and all of 2nd fl are parking; added load is less than 400A 480/277V;REQUESTED FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65764	17041-10000-20717	10250 W SANTA MONICA BLVD # 1885	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/20/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	First tenant - Ali Jay- in retail space at the Century City Mall # 1885	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65765	11041-20004-26376	13450 W MAXELLA AVE	90292	11	105B153    47	4212004021	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	06/04/2013 12:00:00 AM	ADDRESS	33.98645	-118.44148	Delta 5 modification to plan to show and to provide exterior emergency lighting using unit equipment and lighting connected to emergency generator.  No new lighting added to change T-24 lighting requirements.  Rewired lighting connected to emergency panels to be controlled as normal lighting with all required controls exterior.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65766	12041-10000-30035	9045 N TOPANGA CANYON BLVD	91311	12	198B101   319	2010004045	C4-1, RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	PIN	34.23511345	-118.60526896	TITLE 24 PLAN CHECK AND EMERGENCY LIGHTS FOR A RESTAURANT TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65767	19041-10000-53555	13230 W SATICOY ST	91605	2	186B157   209	2303028002	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	04/23/2020 12:00:00 AM		Permit Finaled	01/17/2023 12:00:00 AM	ADDRESS	34.20783	-118.42137	Title 24 energy plan check. Scope of work includes new power equipment. Adding new panelboards and circuits. Total affective area: 185,935sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65768	15041-20000-23640	8022 W OKEAN TER	90046	4	156B173   343	5570019026	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Issued	08/28/2015 12:00:00 AM	ADDRESS	34.12364	-118.37205	$0 permit fee due to senate bill 1222 from 2012Installation of new roof mounted solar PV array.  Total system size = 20 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65769	14041-10000-08276	1700 E CESAR E CHAVEZ AVE SUITE 1100	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.05093	-118.21753	T24 FOR EXISTING OFFICE BUILDING. SCOPE OF WORK ON SUITE 1100. NOT A HIGHRISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65770	13041-20000-26792	18741 W FRANKFORT ST	91324	12	192B121   692	2785021008	RS-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.22145	-118.5418	New 10.4kw rooftop PV system for an existing single family dwelling.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65771	15041-20000-19489	2734 N FLETCHER DR	90039	13	151-5A211  83	5436031015	[Q]C2-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM			PC Approved	06/22/2015 12:00:00 AM	ADDRESS	34.11088	-118.25053	Title 24 plan check only.  Total area = 3,125 sq. ft.  T.I. to existing commercial space.  Change of use from retail to office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65772	14041-20000-30550	15474 W DUOMO VIA	90077	5	156B145   197	4378036019	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM			PC Info Complete	12/05/2014 12:00:00 AM	ADDRESS	34.12386	-118.47023	PV1Install a GROUND-mounted solar array for a SFD. Interconnect with 600A MSP.System size: 13.975kW(65) EnPhase M215-IG microinverters with (65) 270W pv modules across 4 strings (17+17+16+15).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65773	19041-10000-46443	9825 N OWENSMOUTH AVE	91311	12	201B105   101	2746017022	MR1-1, [Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	09/03/2020 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.24892	-118.6019	FULL PLAN CHECK FOR CHANGE OF USE TO HYDROPONIC FACILITY TI. SCOPE INCLUDES 4 NEW PANELS CONNECTED TO AN EXISTING SERVICE OF 400 AMP TOTAL AFFECTED AREA: 6424 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65774	19041-10000-49962	11543 N VENEZIA WAY	91326	12	213B109   535	2701070042	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.28137	-118.58459	PC for PV-1 system, system size is 5.12KW, system consist of 16 modules with P320 optimizers. (1) 3800H inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65775	17041-10000-42639	200 E VERNON AVE	90011	9	112-5A205  78	5109011057	R3-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Issued	11/28/2017 12:00:00 AM	ADDRESS	34.00365	-118.27159	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65776	17041-20001-43976	4834 N ARCOLA AVE	91601	4	168B177   382	2420014020	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.15868	-118.35484	expeditepv1install roof mounted pv system sized 6.6kw with battery back up inteconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65777	12041-20000-27017	11755 W WILSHIRE BLVD	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	05/06/2013 12:00:00 AM	PIN	34.04869377	-118.46238681	Express permit is for seven 277V lighting circuits.Plan check for energy and emergency lighting. Main entry lobbie, elevator lobbies, and basement. 3317 conditioned sqft and 1163 unconditioned sqft. High-rise building. THE LANDMARK WILSHIRE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65778	14041-10001-31542	12323 W HATTERAS ST	91607	2	174B165   227	2340013017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.17543	-118.40156	SFD ROOF-MOUNTED PHOTOVOLTAIC 6KW SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65779	18041-20001-16562	7600 N BALBOA BLVD #204	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Approved	07/19/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Revisions to approved set.  SLD changed to reflect (N) panel with (N) feeder.  (((Plan check for first time tenant retail space new lighting and receptacle. Total area: 1040 sq ft.B#18016-10000-13841)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65780	14041-10000-23280	21447 W ALAMO ST	91364	3	166-5A107 119	2190015056	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.1504	-118.59717	PV1, 5KW AC roof-mounted system including (1) Solaredge SE5000A  inverter, (20) Sunmodule SW275 modules and Solaredge Power Optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65781	18041-10000-27905	14715 W ARMINTA ST	91402	6	189B149   475	2210021013	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	07/01/2020 12:00:00 AM	ADDRESS	34.21361	-118.45363	SERVICE UPGRADE TO 600 AMP, 277/480V, 3PH PLUS NEW PANELS & TRANSFORMERS FOR FUTURE GROW HOUSE. CORE & SHELL ONLY. FUTURE TI's REQUIRES COMPLETE ELECTRICAL PLAN CHECK & BUILDING PERMIT. BUILDING PERMIT: 18016-10000-34293	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65782	14041-10000-11720	2512 S WESTWOOD BLVD	90064	5	126B157  1115	4255026002	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.03878	-118.42719	PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZEER. 18 MODULES. 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65783	15041-20000-23542	951 S KENISTON AVE	90019	4	132B185   490	5090003008	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.05785	-118.33594	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65784	14041-20000-27895	11636 W BARRINGTON CT	90049	11	135B145   589	4401006013	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.0649	-118.46925	TI to (E) 848 sq. ft. commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65785	15041-20001-40515	17260 W GRESHAM ST	91325	12	195B133   344	2768016016	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM			PC Approved	12/29/2015 12:00:00 AM	ADDRESS	34.23029	-118.51077	Expedited per customer request.PV1. Install roof mounted PV system sized 7.3 kW. Interconnected with main service panel.(34) Solar World SW285 Modules(34) Enphase M215 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65786	18041-20000-44065	15503 W VENTURA BLVD Ste 340	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.15504	-118.4723	Plan check for power and energy. Project site is the 3rd floor of an exising commercial building. Project scope is a change of use from office to medical office. Total lighting area = 3,452 sq. ft.Note: Building application has been generated under 18016-10000/10001-07622	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65787	18041-10000-08413	1256 W 7TH ST	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/18/2023 12:00:00 AM	ADDRESS	34.05216	-118.26774	PC FOR FIRE ALARM SYSTEM IN A 15TH STORY HIGHRISE HOTEL BUILDING. TOTAL DEVICE COUNT 458 WITH 7 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65788	13041-10002-30052	1201 N LAS PALMAS AVE	90038	4	144B185  1344	5532004037	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.09272	-118.33648	Expedited RSES plan check per applicant request.(((PV1, Install 1.59m kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US. 6 modules Suniva OPT265-60-4-1B0.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65789	12041-10000-01623	22115 W ROSCOE BLVD	91304	12	192B101   520	2010023034	(T)(Q)C1.5-1, C2-1L, P-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM			PC Approved	01/23/2012 12:00:00 AM	ADDRESS	34.21979	-118.60892	TI in the Common area of the residential Bldg. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65790	16041-20001-40154	3931 N KINGSWOOD ROAD	91403	4	163-5A145  80	2281014005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.14244	-118.4673	Expedited per applicant request.Plan check for the addition of a PV system onto an existing PV1 roof-mounted PV system. System addition size is 5 kWac for a total system size of 10 kWac. System addition consists of (1) inverter and (22) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65791	13041-10000-03620	10054 N WYSTONE AVE	91324	12	204B121   434	2729004020	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Expired	03/10/2015 12:00:00 AM	ADDRESS	34.25332	-118.54684	PV1 for single story house. Total system size: 12.74 kW. [Inverter: Fronius IG Plus Model#: Fronuis IG Plus 11.4] [Solar Module: Trina Mount 2 Model#: TSM-245-PC/PA05.18]. 52 Modules used with 1 central inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65792	16041-10000-41969	5870 S CRENSHAW BLVD	90043	8	105B185     9	4005005022	P-1, [Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	33.98771	-118.33052	T-24, PC FOR ENERGY ONLY.  TI OF EXISTING RETAIL SPACE, REMOVING EXISTING 2-FLOOR AND REDEMISING 3-BAYS INTO 1-BAY, AND ADDING (3) NEW AC UNITS ON ROOF. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING RETAIL SPACE. TOTAL AFFECTED AREA IS 7691 SQ. FT. B#16016-10000-27398	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65793	18041-20000-25652	2700 W COLORADO BLVD	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.14248	-118.22438	Plan check for Title 24 only. Project site is an existing commercial  building. Project scope is a change of technology from fluorescent to LED for (6) cabinet/walls signs. Total lighting area = 671 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65794	14041-20000-33576	1000 W WILSHIRE BLVD Suite 870	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Issued	12/05/2014 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for energy only. TI to existing office on the eigth floor of a high-rise office building. Install new receptacles and lighting (incl. emergency). 3,484sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65795	15041-10006-27142	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			10/03/2016 12:00:00 AM			PC Approved	10/03/2016 12:00:00 AM	ADDRESS	33.93845	-118.42964	RECHECKING APPROVED SET OF PLANS. SOME PAGES NOTED DELTA 8 WITH NO CHANGE ON FLOOR PLANS. RECHECKING DUE TO MISSING RTI STAMP. THESE PAGES WILL BE PART OF DELTA 7 REVIEW AND PERMIT. THIS APPLICATION PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65796	12041-10000-22322	2533-2535 W OLYMPIC BLVD	90006	1	130-5A201 363	5076005***		Central				2134.01	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Info Complete	11/13/2012 12:00:00 AM	ADDRESS	34.05258	-118.28565	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT IN A 6-STORY MIXED USE BUILDING. 1 RETAIL AND 1 OFFICE SPACE. (2 Panel boards are existing)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65797	12041-10000-21493	6060 W CENTER DR	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			PC Approved	09/11/2012 12:00:00 AM	ADDRESS	33.97602	-118.39073	Ti in an office. EPC is for T24. (9th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65798	15041-10000-22094	12907 W SUNSET BLVD	90049	11	132B137   407	4406009015	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.05724	-118.49153	PV1 10.07KW ROOF MOUNTED PV SYSTEM(38) KYOCERA #KU2656ZPA(2) INVERTERS PVI-5000-OUTD-US-Z-A, PVI-3.0-OUTD-S-US-Z-Afees per applicant	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65799	18041-10000-26896	808 S BROADWAY 100 & 200	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.04342	-118.25478	3 STORY TI; CHANGE OF USE FROM RETAIL TO CAFE & RETAIL IN SUITE #'S 100 & 200.PLAN CHECK FOR POWER AND ENERGY. AREA: 10,212 SQR FT.BUILDING PERMIT: 18016-10000-22936	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65800	16041-10000-34457	12615 W BEATRICE ST	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	33.98049	-118.41636	Plan check for power and energy T.I. existing media production space new generator 250KVA and UPS 200KVA System being install and ATS. 39,843 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65801	15041-20000-22574	15205 FRED WAY	91405	6	186B145  1130		(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	PIN	34.20923857	-118.4642762	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65802	17041-10000-25663	13513 W HUBBARD ST	91342	7	225B157   803	2509016012	C2-1-CPIO	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.30989	-118.4279	TITLE 24 PLAN CHECK TO REPLACE EXISTING (6) FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA = 10300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65803	12041-10000-09088	5340 S ALLA ROAD	90066	11	102B157    39	4211008023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/20/2012 12:00:00 AM			PC Approved	05/31/2012 12:00:00 AM	ADDRESS	33.9773	-118.42567	T.I. to an existing 2-story office building.  Occupant load is less than 99 and load is 391A per applicant.  PLAN CHECK ONLY for T-24, with Emergency lighting.  (All LED lighting to be listed/tested to an Approved testing standard per the applicant - approval shall be provided to inspector.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65804	12041-10001-19947	8655 S SEPULVEDA BLVD	90045	11	096B165   768	4122001003	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM			PC Approved	05/29/2013 12:00:00 AM	ADDRESS	33.95844	-118.39645	Modifications to approved set of plans. Removal of main (per utitlity request to the applicant). Delta changes are clouded on plan sheet E00.10***********************************************************************Originap plan check descritpion 12041-10000-19947: Plan check power and energy. Existing building (retail core & shell electrical).  New 1200 Amp service, panels, lighting and loads for future tenant.  Variance to separate fire alarm system has been filed. Future tenant subject for complete plan review.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65805	19041-20000-23264	20865 W LASSEN ST	91311	12	201B109    90	2741002005	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.25013	-118.58809	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65806	17041-10000-14111	7911 S VERMONT AVE	90044	8	099B197   511	6019016008	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/23/2017 12:00:00 AM	ADDRESS	33.96745	-118.29199	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 10050 SQ. FT. TOTAL OF 7 FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65807	11041-20000-12903	7311 N FIGUEROA ST	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.13623	-118.18853	"Adding lighting and receptacles to addition for pharmacy.  Plan check is for energy only.""COMPLY WITH DEPARTMENT ORDER effective date07/09/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65808	15041-20000-11356	23517 W WINDOM ST	91304	12	186B093   259	2027036025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.20651	-118.64078	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 16.35 KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65809	17041-10001-37292	2120 N BEVERLY DR	90210	4	150B161    37	4386016016	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.10999	-118.41899	EXPEDITE PER APPLICANT REQUEST.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.4KWac.(42)MODULES-330W VBHN330SA 16 SANYO PANASONIC(42)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE 11400A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65810	15041-10000-03640	10861 W WEYBURN AVE Target	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.06247	-118.44344	Plan check for T-24. T.I. for Target Phamacy area. Total area: 803 sq/ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65811	13041-10002-29863	735 S FIGUEROA ST # 203	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM			PC Approved	02/14/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	"Delta-7 modifications to approved set for additional emergency lighting control device (automatic load control device Wattstopper ELCU-200).  (((FIRST TIME TENANT FOR A ""MAC COSMETIC"" STORE. PLAN CHECK FOR POWER AND ENERGY. ADDING 2 NEW PANELS, 30KVA XFORMER. EXISTING 1200A, 480/277V 3PH 4W SERVICE. TOTAL ILLUMINATED AREA TO BE 1494 SQ FT.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65812	18041-10000-20168	100 W WORLD WAY Lvl. 2 T1-SWA	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM			PC Info Complete	05/31/2018 12:00:00 AM	PIN	33.94684048	-118.40128468	PC FOR RENOVATION OF SPACES WITHIN TERMINAL 1 OFFICE LEVEL (MEZZANINE) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 2928 SQ.FT B#18016-10000-14473	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65813	14041-10000-01260	5880 W JEFFERSON BLVD SPACE B	90016	10	120B173   380	4205027011	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.02238	-118.37681	CHANGE OF USE FROM OFFICE ) TO TAKE-OUT RESTAURANT, NO SEATING.  Load is less than 200A and occupancy load is 8, per applicant.  PLAN CHECK ONLY for Energy,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65814	15041-20000-11973	2027 N HOBART BLVD	90027	4	151-5A195 235	5589001029	RE9-1	Central	Hollywood	Los Feliz		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.10752	-118.30618	PV1. Install roof mounted PV system sized 7.8 kW. Interconnected with main service panel.(26) LG300 modules(26) Enphase M250 microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65815	13041-10001-34861	500 W WORLD WAY TERMINAL-5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			Corrections Issued	06/13/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	(((((6/13/2014  CHANGES MADE TO APPROVED SET.  REMOVED FIXTURE FROM ROOFTOP PENTHOUSE.  ADDED FIXTURE TO 3RD FLOOR ROOM - PLAN CHECK FEES HAVE BEEN PAID)))))T24 PART 6 ENERGY LIGHTING ONLY; PROJECTED AREA IN SCOPE OF LIGHTING WORK IS APPROX. 1215 SQ FT. FOR LOBBY/MAIN ENTRY & ELECTRICAL ROOM AREAS. SCOPE OF WORK < 400A. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65816	18041-10000-34895	555 W 5TH ST 32ND FLR.	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI TO AN EXISITING OFFICE SPACE NEW LUKMINAIRES AND CIRCUITSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65817	19041-20000-24161	927 N CROFT AVE	90069	5	144B173   310	5529002031	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			06/28/2019 12:00:00 AM			Reviewed by Supervisor	08/02/2019 12:00:00 AM	ADDRESS	34.08775	-118.37435	Plan check for power and energy. Project site is a 4 story, 8 unit apartment building with basement parking garage. Work includes a 600 amp service and a total lighting area of 7,840 sq. ft.Note: Building application has been generated under 18010-20000-05960	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65818	17041-10000-14156	8537 N RESEDA BLVD	91324	12	192B125   181	2785006032	C2-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.2257	-118.53629	TITLE 24 ONLY FOR TI - CHANGE OF USE FROM VETERINARY CLINIC TO MASSAGE PARLOR - TOTAL SQ. FT. (1424)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65819	19041-20000-15264	800 N WESTERN AVE	90029	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.08484	-118.30896	(E) commercial bank tenant improvement.  Plan check for energy - 367 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65820	18041-10000-29178	960 N LA BREA AVE	90038	4	144B181   634	5531015004	(Q)M1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	07/20/2022 12:00:00 AM	ADDRESS	34.08868	-118.34386	"New 5 story commercial building. Full plan check for power and energy.Bldg Permit"" 18016-10000-09955"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65821	18041-10000-20122	1203-1205 S OLIVE ST	90015	14	126A207   156	5139023009	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.03935	-118.26257	CHANGE OF USE FROM (E) 1-STORY URM OFFICE BUILDING TO PROPOSED BREWERY; REPLACEMENT OF PANELBOARDS AND NEW CIRCUITS.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65822	17041-10000-46604	11848 N JELLICO AVE	91344	12	216B129   380	2601042033	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.28477	-118.51719	PLAN CHECK FOR GROUND MOUNTED PV SYSTEM. SYSTEM SIZE 11.4KW CONSISTING OF 1 CENTRAL INVERTER (SE 11400A-US) WITH 36 MODULES AND POWER OPTIMIZERS(P370).BUILDING PERMIT IS REQUIRED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65823	14041-20000-12411	7733 N HASKELL AVE	91406	6	189B141   250	2206011039	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM			Corrections Issued 2	05/09/2014 12:00:00 AM	ADDRESS	34.21117	-118.47511	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65824	19041-20001-14162	11100 W MAGNOLIA BLVD	91601	2	171B173   614	2353005029	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM			PC Approved	08/06/2019 12:00:00 AM	ADDRESS	34.16478	-118.37255	Plan check for Title 24 Part 6 lighting requirements. (((RELOCATE PANEL 200AMPS, (72) EXISTING CIRCUITS; LIGHTS FIXTURES GFI BATHROOM AND KITCHEN AND RECEPTACLES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65825	19041-10000-41011	757 S ALAMEDA ST	90021	14	123A215     2	5146009001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM	ADDRESS	34.0318	-118.23916	FULL PLAN CHECK FOR A FIRST TIME TENANT(3rd floor). SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS WITH (2) 400 SWITCHBOARDS CONNECTED TO AN EXISTING 4000A SUBSTATION 277/480 SERVED FROM A (E) MEDIUM VOLTAGE SERVICE DISTRIBUTION BOARD. TOTAL AFFECTED AREA IS 46840 SQ.FTB#19016-10000-32306	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65826	15041-20001-18517	19155 W VICTORY BLVD #3	91335	3	180B121   526	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Apartment			06/15/2015 12:00:00 AM			PC Approved	06/25/2015 12:00:00 AM	ADDRESS	34.18675	-118.55116	Expedite per applicant request[[[[[Plan check for PV roof mounted system. System size: 10kW with 35 modules and 2 inverters(6.0kW & 4.0kW) connected to 200A unit panel and connected to 600A Meter Bank]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65827	13041-20000-19102	1857 N HILLHURST AVE	90027	4	150B197   941	5590016026	[Q]C4-2D	Central	Hollywood	Greater Griffith Park		1891.01	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM	03/07/2014 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.10474	-118.28758	PLAN CHECK FOR SERVICE UPGRADE TO 800 AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65828	11041-10003-25713	18510 W VICTORY BLVD	91335	3	180B125   658	2127012009	C4-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			PC Approved	04/15/2013 12:00:00 AM	ADDRESS	34.18638	-118.53642	Brand new McDonalds with new 1000A service and seven new subpanels, with new equipment and circuits.  Plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65829	13041-20002-29740	19373 W VICTORY BLVD STORE 1656	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM			PC Approved	02/10/2015 12:00:00 AM	ADDRESS	34.1878	-118.5556	REVISIONS TO AN APPROVED SET OF PLANS.  RELOCATING OF TRANSFORMER.FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW RETAIL SINGLE STORY 'ROSS' STORE. SCOPE OF WORK INCLUDES INTERIOR LIGHTING, ADDITION OF OFFICES, AND NEW EXTERIOR SIGNAGE. TOTAL AREA FOR LIGHTING = 31274 (INDOOR + OUTDOOR). EMERGENCY FIXTURES/EXIT SIGNS WILL BE ON UNIT EQUIPMENT. EXISTING 800A 277/480-Y-3PHASE, 4WIRE SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65830	14041-20000-20037	16034 W SKYTOP ROAD	91436	5	162B141   189	2286013018	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	10/11/2014 12:00:00 AM	ADDRESS	34.14106	-118.48246	PV1.  Install 7.68 kW roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65831	19041-10000-08221	4900 W WASHINGTON BLVD	90016	10	126B181  1115	5062003024	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.03992	-118.34608	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65832	16041-20000-14356	21100 W SUPERIOR ST	91311	12	198B113   183	2748001044	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.24623	-118.59342	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 27260.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65833	18041-10000-24623	2140 W OLYMPIC BLVD	90006	1	130-5A201 166	5136013023	C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	34.05183	-118.28061	Energy plan check for a change of use from existing office to a community center for adult day care. Scope inlcudes new lighting and equipment with a total Title-24 area is 11,802 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65834	19041-20000-49636	5011 N LLANO DR	91364	3	168B101    44	2170001054	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.16023	-118.61231	PV1. INSTALL 11.34 KW DC PV SYSTEM WITH (36) MODULES/OPTIMIZERS AND (1) INVERTER(SE10000H-US)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65835	17041-20000-42948	1301 S WESTGATE AVE 1-27	90025	11	126B145    84	4263023020	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Apartment			11/29/2017 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	09/26/2021 12:00:00 AM	ADDRESS	34.04507	-118.46183	New 4-story, 27-unit apartment.  1200A 208Y/120V 3ph-4w service.  Building permit filed under 16010-10000-05665	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65836	12041-20000-29843	16112 W VENTURA BLVD	91436	5	168B141   983	2284003048	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Closed	05/04/2015 12:00:00 AM	ADDRESS	34.15621	-118.48419	Plan check for power and energy. 1st time tenant. 1686 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65837	19041-10000-29764	1904 W ADAMS BLVD	90018	8	123B193   630	5053019002	C2-1VL-O-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	34.03251	-118.30624	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65838	15041-20000-15002	2980 N ALLESANDRO ST	90039	13	150B213   731	5442024030	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.10564	-118.2445	40 unit apartment. live work. retail first level. mix use building. plan check for power and energy. fire alarm variance has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65839	17041-10000-15808	1173 S ROBERTSON BLVD	90035	5	132B169   847	4332014018	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.05519	-118.38393	PC FOR TITLE-24, ENERGY ONLY FOR A COFFEE SHOP. TOTAL AFFECTED AREA 467 SQ.FT.SCOPE INCLUDES NEW CIRCUITS AND NEW LIGHTS.B#16016-20000-19060	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65840	16041-20000-32703	255 S ALEXANDRIA AVE 1-35	90004	13	135B197   106	5518008024	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2113.10	Electrical	Electrical	Apartment			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.06961	-118.29805	Plan check for emergency exit signs. New exit signs/bug lights for corridors of floors 1-3 and subterranean garage of existing apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65841	15041-10000-34585	10430 N SEPULVEDA BLVD	91345	7	207B145   770	2649019009	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Closed	01/26/2018 12:00:00 AM	ADDRESS	34.26014	-118.46701	PC FOR POWER AND ENERGY FOR A RETAIL SHELL BUILDING. TOTAL AREA 3750 SQ FT(CANOPY AREA).BUILDING # 15010-10000-03495	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65842	16041-10000-33481	17552 W HAMLIN ST	91406	6	180B129   751	2229027023	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.1884	-118.51613	PV1. NEW SOLAR SYSTM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.175KWdc / 4.80KWac. (15)AC MODULES-SPR-X21-345-C-AC(1)125A SUBPANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65843	14041-20000-28696	18935 W COVELLO ST	91335	3	186B121   235	2104014018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.20759	-118.54618	PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING TOTAL OF 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65844	13041-10004-19659	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			12/21/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.09918	-118.32644	((12-21-15: CHANGES MADE TO APPROVED SET. SHORT CIRCUIT CALCULATIONS PER INSPECTOR AND ADDED SERIES RATING COMBINATIONS WITH MOTOR LOAD CONTRIBUTIONS. PLAN CHECK ONLY))POWER AND ENERGY PLAN CHECK 287 UNIT APARTMENT BUILDING WITH FUTURE RETAIL SPACES. 7 STORY  LOW RISE BUILDING. VARIANCE TO SEPERATE FIRE ALARM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65845	19041-10000-07843	20929 W VENTURA BLVD UNIT 12	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTING AND EXIT SIGN TO EMPTY TENANT SPACE FOR FUTURE TENANTPLAN CHECK IS FOR TITLR 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65846	17041-10000-25123	5412 W MONROE ST	90038	13	141B193   250	5535013011	R2-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.08565	-118.31181	PLAN CKECK FOR BATTERY BACK UP SYSTEM - SYSTEM SIZE = 13.5KWH.SCOPE INCLUDES BATTERY AND LOAD CENTERPV SYSTEM UNDER PERMIT # 17041-10000-25117	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65847	11041-20000-00470	1715 N GOWER ST	90028	13	148-5A189  87	5546032019	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM	01/10/2011 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	ADDRESS	34.10216	-118.32254	PLAN CHECK T24 ENERGY FOR 3 NEW OFFICES TI WITH INTERIOR ROOF WITHIN BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65848	10041-10000-08427	11755 W CHENAULT ST	90049	11	132B145   316	4401013002	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2010 12:00:00 AM			Corrections Issued	05/23/2010 12:00:00 AM	ADDRESS	34.05517	-118.46931	New Single family home. Plan check for power. (originally designed by different engineer and plan checked unde plan check # 09041-20000-24728)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65849	15041-10000-40131	659 N OCCIDENTAL BLVD	90026	13	139-5A203 705	5401026012	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.07846	-118.27498	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 1.750KWac. (7)MODULES-SOLARWORLD-SW 280MBLK(7)MICROINVERTERS-ENPHASE-M250-60-2LL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65850	14041-10000-30554	8000 W SUNSET BLVD ste B310	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.09783	-118.36466	T24 total area = 3612sq ft.  Tenant improvement 3rd floor of existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65851	18041-10000-15480	8771 N VAN NUYS BLVD	91402	6	195B149   498	2653002062	[Q]CR-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.22938	-118.45045	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65852	18041-20000-18504	14840 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.29474	-118.45444	PV1.  Install 3.78 kW roof mounted grid tied PV system.  (12) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65853	14041-10000-02369	8631 N ROSLYNDALE AVE	91331	6	192B157    47	2627026002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	ADDRESS	34.2268	-118.42033	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH OPTOMIZERS. SYSTEM SIZE: 4 KW. TWO STORY HOUSE.(16) TRINA SOLAR #TSM-250(16) SOLAREDGE OP300 OPTOMIZERS(1) SOLAR EDGE #SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65854	15041-10000-04462	1000 W WILSHIRE BLVD Suite 240	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	Title 24 plan check only.  Total area = 1,350 sq. ft.T.I. to existing highrise office space including new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65855	18041-10000-10978	1140 E 11TH ST	90021	14	123A213   156	5132015046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.03133	-118.24592	PLAN CHECK FOR TITLE 24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65856	16041-10001-36460	2432 S PENMAR AVE 1-4	90291	11	108B149   449	4236004007	RD1.5-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Apartment			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	33.99404	-118.45027	08-25-2017 Changes to an permitted set of plan. Changes include different type of lighting fixtures. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65857	14041-10001-08931	12806 W STANWOOD DR	90066	11	114B149    76	4247010015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/12/2014 12:00:00 AM	ADDRESS	34.01205	-118.44934	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65858	14041-10000-22667	4300 S CENTRAL AVE	90011	9	114A209   261	5115033039	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.00558	-118.25579	Title 24 plan check only.  Total area = 8,571 sq. ft.T.I. to existing retail space.  Adding 3 new panels fed from existing switchgear (connected load = 400 A) and new lighting fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65859	18041-10000-30246	13892 W FOOTHILL BLVD	91342	7	225B153   364	2509003003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.31173	-118.43626	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65860	11041-20000-14808	127 S SAN VICENTE BLVD Bulletin-70 C & S	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	07/25/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION delta # 70 C & S	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65861	16041-20000-41893	14047 W BURBANK BLVD	91401	2	174B153   758	2246032012	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	34.17233	-118.43924	Plan check for power and energy. Project site is a dental office. Project scope is a tenant improvement. Total lighting area = 1,500 sq. ft.Note: Building application has been generated under	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65862	17041-20000-21980	14535 W GILMORE ST	91411	6	180B149   672	2236016020	[Q]CR-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.18781	-118.45002	ti to an existing dental office.  adding new lighting new controls to new panels.  plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65863	14041-10000-17797	752 S LOS ANGELES ST	90014	14	127-5A211 277	5145003002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM			PC Info Complete	03/11/2015 12:00:00 AM	ADDRESS	34.04211	-118.25167	PC FOR POWER AND ENERGY. HIGH RISE. CHANGE OF USE FROM EXISTING LIGHT MANUFACTURING TO RETAIL AT FIRST FLR AND MEZZ, AND 54 JOINT LIVE-WORK UNITS AT SECOND THROUGH 10TH FLOORS PER CH. 85. INTERIOR REMODEL SECOND THRU 10TH FLOORS FOR LIVE/WORK UNITS. STRUCTURAL STRENGTHENING. TOTAL AREA 7315 SQ FT.Plan checker verify the address job.BUILDING APP#: 14016-10000-06867	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65864	16041-10000-37332	10747 W CHANDLER BLVD	91601	2	171B177   100	2416016010	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM	10/15/2018 12:00:00 AM		Issued	10/15/2018 12:00:00 AM	ADDRESS	34.16881	-118.36519	FULL PC SERVICE UPGRADE TO 600A AND COMBINE MULTI METER TO SINGLE SWITCHBOARD. TENANT IMPROVEMENT TO AN OFFICE. TOTAL SQ. FT. 1995	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65865	17041-30000-33858	421 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	33.77395	-118.27891	Plan check for Title 24 only in existing space wearhouse and office T.I. Total area: 9,000 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65866	15041-10000-17188	5529 W HOLLYWOOD BLVD	90028	13	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.10188	-118.31029	ti to an existing single story commercial building. ti for  first time tenenat plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65867	15041-20000-35686	523 W 6TH ST 2ND FLR	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI;  NEW SUSPENDED CEILING AND LIGHTING AT SECOND FLOOR ELEVATOR LOBBY  812 SQ FTPC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65868	12041-10000-02284	127 S SAN VICENTE BLVD Bulletin-144CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM			PC Approved	01/31/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 144 plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65869	16041-10000-32087	801 S FIGUEROA ST FLR 25TH	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR SUITE 2500. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 462 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65870	13041-20001-28854	6200 N LEDERER AVE	91367	3	177B093   319	2035012020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	11/14/2013 12:00:00 AM	ADDRESS	34.18306	-118.63905	EXPEDITE FEES ONLY<<<New rooftop mounted PV system for an existing single family residence.  System is UNGROUNDED.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65871	13041-20000-19951	3418 S 3RD AVE	90018	10	120B189   820	5042002044	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.02486	-118.31992	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW USING 15 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65872	14041-20001-01153	117 E MAST MALL	90292	11	102A147   131	4295003007	R1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	03/21/2014 12:00:00 AM	ADDRESS	33.97332	-118.45914	pc for change in module type only. new module type 255w rated. no other changes. clouded red.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65873	11041-20000-04721	7425 N BERNADINE AVE	91304	3	186B093   316	2027008042	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21, 1344.22	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	34.20583	-118.63829	New 6.7KW PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65874	14041-20000-30921	24642 W WOODGLADE LANE	91307	12	186B085   134	2031004057	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.20226	-118.66014	PV1Install roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 4kW. Ungrounded system.1 string of (16) EnPhase M250 pv modules with (16) 275W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65875	18041-20000-07733	9119 N BALLARD DR	91311	12	198B101   336	2727024001	(T)(Q)RD3-1, A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.23579	-118.60725	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65876	14041-10000-00127	19315 W PARTHENIA ST	91324	12	195B117   192	2783027001	[Q]C2-1VL	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.22838	-118.5543	INSTALLATION OF NEW FIRE ALARM SYSTEM WITH (1) FACP , 12 DEVICES, (1) ANNUNCIATOR PNL IN SINGLE STORY, APPROX 3500 SQ FT 'MCDONALDS'.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65877	17041-20000-01583	23000 W HARTLAND ST	91307	12	183B097   775	2026010001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.19447	-118.62847	PV1. ROOFMOUNTED SOLAR. ADDITION TO EXISTING PV SYSTEM. ADDITION: 2.28 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65878	16041-10000-28288	1418 N NORTH SPRING ST #102	90012	1	136-5A217  75	5409004002	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.06685	-118.23206	Plan Check Title 24 only in existing building T.I. office. Total area: 6,445 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65879	13041-20000-27269	16310 W RAYMER ST	91406	6	189B137    16	2205029035	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.21777	-118.48799	TI FOR EXISTING RESEARCH LAB. RETROFITTING LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65880	11041-20000-22281	1250 N TOWER GROVE DR	90210	5	144B157   145	4356026004	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2011 12:00:00 AM			PC Approved	01/03/2013 12:00:00 AM	ADDRESS	34.09352	-118.4241	PLAN CHECK FOR NEW 2-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE NEW 600A SERVICE SERVING MAIN HOUSE AND GUEST HOUSE. (EPC 2 0F 2) Plan Check Only, Permit is under a separate application per contractor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65881	19041-20000-33565	8518 N PONCE AVE	91304	12	192B097    70	2004013026	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.22515	-118.62126	Plan check for PV roof mounted system installed in addtion to existing system, Addition system size: 1.55KW  with	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65882	14041-20000-16691	11000 N RATHBURN AVE	91326	12	210B125   580	2715005059	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.26982	-118.53263	PV1.  Install 7.5 kW roof-mounted, utility-interactive PV system.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65883	16041-10000-16248	1326 S CENTINELA AVE 1-9	90025	11	126B145   813	4267034013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			05/09/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.03942	-118.46844	installation of new fa system with one fa panel, one communication panel and 61 fa devices. 10 control devices. for  a new 4-story 10-unit apartment building (16,278 s.f.) over 1 level subter. parking(7,250 s.f.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65884	15041-10000-08267	3669 E WHITTIER BLVD	90023	14	121-5A229  71	5188008027	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/08/2015 12:00:00 AM	ADDRESS	34.02484	-118.19388	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65885	12041-20000-16585	221 S FIGUEROA ST	90012	9	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.05628	-118.25373	T.I. to existing building on 4th (Suite #400) and 5th (Suite #500) floors.  On 4th floor, install/relocate some light fixtures.  On 5th floor, relocate some light fixtures.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65886	17041-10000-02660	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010118	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	PC for new 4 story fire alarm for Google building. PC for 828 devices and 1 FACP, 14 power panels and 1 annunciator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65887	17041-20000-15685	19018 W MERION DR	91326	12	213B121   734	2822034018	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.2775	-118.5483	pv1install roof mounted pv system sized 9kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65888	10041-10000-14634	11400 W ROCHESTER AVE Bldg 4	90025	11	129B149   103	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Corrections Issued	10/06/2010 12:00:00 AM	ADDRESS	34.04842	-118.45404	NEW SERVICE, PANELBOARDS AND CIRCUITS FOR 10 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65889	15041-20000-08094	2824 N NICHOLS CANYON ROAD	90046	4	156B177   610	5570005005	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.12145	-118.35927	Plan check for a PV1 roof-mounted PV system. System size is 6.3 kWac and consists of (25) modules and (25) micro-inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65890	11041-10000-21079	11111 W SANTA MONICA BLVD 19th floor	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	T.I. work to the entire 19th floor.  Plan check for POWER and ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65891	16041-20001-31609	10900 W VINEDALE ST	91352	6	195B173   568	2408010027	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2016 12:00:00 AM			PC Approved	09/14/2016 12:00:00 AM	ADDRESS	34.22758	-118.36792	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (43) modules, and (1) combiner box. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65892	16041-20000-11846	20624 W BLACKHAWK ST	91311	12	204B109   133	2707013011	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.2581	-118.58281	Plan check for a PV1 roof-mounted PV system. System size is 8.5 kWac and consists of (26) ac modules and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65893	14041-20001-15218	5237 N NORWICH AVE	91411	4	172-5A147 215	2250019023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.16592	-118.46087	For expedite only.*****New roof mounted PV system with system size 6.76KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65894	17041-20001-09615	9351 N LAUREL CANYON BLVD	91331	6	198B161   272	2629027014	(Q)MR1-1, (Q)P-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM			PC Approved	10/09/2019 12:00:00 AM	ADDRESS	34.23901	-118.41146	10/9/19CHANGES TO APPROVED SET DELTA 7 ONLY. CHANGES TO SHORT CIRCUIT CALC AND DELTA LOAD.<<<Plan check for power only. Project site is an existing commercial building (H-3 occupancy), chemical storage and no hazardous areas. Project scope is the installation of a generator and new load on existing distribution equipment.Note: Building application has been generated under 17016-20000-06967>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65895	18041-20000-17572	11626 W VENTURA BLVD	91604	2	162B169   488	2369034004	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.1404	-118.38568	Plan check for Title 24 Energy Only, in existing spce T.I. Beauty Salon. Total area: 768 sq ft.B#18016-20000-00807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65896	10041-20000-11754	8065 N WEBB AVE	91605	6	189B169    98	2310008003	C2-1VL, M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM			PC Info Complete	08/02/2010 12:00:00 AM	ADDRESS	34.21748	-118.38966	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR CHANGE OF USE FROM RETAIL TO TAKE-OUT RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65897	18041-10000-20005	5901 W OLYMPIC BLVD #310	90036	4	132B177   666	5086024025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.05771	-118.35996	TI IN AN EXISTING MEDICAL BUILDING. NEW PANELS, TRANSFORMER, CIRCUTS & LIGHTS. FULL PLAN CHECK FOR POWER AND ENERGY.  BUILDING PERMIT #18016-10000-16402NOTE THAT CORRECT ADDRESS IS 1132 N GLENDALE BLVD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65898	19041-20001-00958	9661 W WENTWORTH ST	91040	7	207B181    32	2549004012	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.26427	-118.34278	Expedite per applicant requestPlan check for PV roof mounted system, sytem size: 17.2kW with 58 PV Modules and 2 inverters(7.6kW)  connected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65899	17041-10000-28666	6109 S WESTERN AVE	90047	8	105B193   698	6001015008	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	33.98406	-118.30912	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ FT 6,800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65900	14041-10000-21403	14402 W CALIFA ST #9	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65901	15041-20000-07901	10580 N DES MOINES AVE	91326	12	207B117   318	2728005004	RE11-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	34.2628	-118.55589	Installation of new roof mounted solar PV array.  Total system size = 10 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65902	13041-10000-25174	4222 N VINELAND AVE	91602	2	165B173  1260	2366020002	[Q]C2-2D	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.03	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.1455	-118.37004	TITLE-24, TENANT IMPROVEMENT FOR OFFICES IN 1685 SF IN A SINGLE STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65903	19041-20000-33633	1801 CENTURY PARK EAST Ste. 110	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	PIN	34.0621869	-118.41581732	Tenant improvement to (E) office in a high-rise building. T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65904	19041-20000-09203	1443 N FULLER AVE ev2	90046	4	147B181   757	5550018025	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			03/14/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.09721	-118.34969	addition of (28) EV chargers to an existing apartment building.  plan check for power .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65905	12041-10000-15731	8267 W BEVERLY BLVD	90048	5	138B173   392	5514009053	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	34.07623	-118.3696	Plan check for energy and emergency lighting. Restaurant. Occupancy load of 79 with fixed seating. 2898 sqft. Low-rise commercial.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65906	12041-10000-15595	3060 S CRENSHAW BLVD SUITE A	90018	10	120B185   832	5051029032	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			07/05/2012 12:00:00 AM	10/24/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.02579	-118.33489	First time tenant for a bank.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65907	17041-10001-35533	1726 N NORTH SPRING ST	90012	1	136-5A219  47	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM			PC Approved	04/18/2019 12:00:00 AM	ADDRESS	34.06983	-118.2261	Plan Check Only Changes to an approved set of plans all under delta 1. The changes is reducing the scope of work, outdoor lighting is no longer in the scope. The scope of work now only consists of the indoor lighting in a electrical room. ((PC for power and energy for new service to two buildings C and D. Installing new 4000A 120/208V service in new electrical room, new outdoor lights, conduit runs only to other buildings and two subpanels. Building# 17010-30000-03758. Total area is  65679sqft.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65908	16041-30000-20836	9434 N KESTER AVE	91402	6	198B149    94	2650031014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/20/2016 12:00:00 AM	ADDRESS	34.24197	-118.45566	Plan check for a PV1 roof-mounted PV system. System size is 7.2 kWac and consists of (2) inverters, (26) modules, (2) combiner boxes, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65909	13041-20000-32181	21300 W VICTORY BLVD #100	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.18813	-118.59618	Change to lighting in an existing high rise office.  Load is less than 400 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65910	15041-10000-18017	1731 S OCEAN FRONT WALK	90291	11	106-5A143 104	4226010023	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM			PC Info Complete	07/02/2015 12:00:00 AM	ADDRESS	33.98599	-118.4728	Energy plan check for retail T.I; Scope of work including new lighting ,equipment, and receptacles for combining  (2) existing retail stores into one.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65911	15041-10001-33958	9805 W BURGEN AVE	90034	5	123B165   418	4311002026	R1-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM			Verifications in Progress	01/12/2016 12:00:00 AM	ADDRESS	34.03471	-118.39911	EXPEDITED FEES FOR ROOF SOLAR SYSTEM. PV1. SOLAR ROOF MOUNTED SYSTEM, TOTAL SIZE 6KW. NEW LOAD PANEL WITH EXISTING LOADS.  (30) MODULES AND (1) INVERTER. (30) KYOCERA #KU2656ZPA(1) ABB #PV1-6000-OUTD-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65912	19041-10000-00496	228 S OXFORD AVE	90004	10	135B193    29	5517008022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.10	Electrical	Electrical	Commercial			01/04/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.07023	-118.30773	Change of use of (e) 3,600 sf 2-story SFD to a restaurant. Create uncovered outdoor dining deck on top of (e) patio cover (260 sf).FULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65913	19041-10000-05491	2753 N STONE VIEW CT	90068	4	153B181   590	5549031***	(T)(Q)RD3-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.11866	-118.34297	PLAN CHECK FOR 5.0KVA ROOF MOUNTED SYSTEM USING 1 CENTRAL INVERTER(SE5000H-US) WITH 24 MODULES USING P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65914	19041-10000-12115	5425-5431 S NORMANDIE AVE	90037	8	108B193   673	5003017029	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	Apartment			04/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	04/11/2020 12:00:00 AM	ADDRESS	33.99251	-118.30035	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 10 UNIT APARTMENT. SCOPE OF WORK INCLUDES NEW 400AMPS SERVICE,120/240 1PH, CIRCUITS EQUIPMENTS AND LIGHTIN. TOTAL EFFECTED AREA 980 SQFT.NOTE: PLAN CHECKER ADD 28 NEW BRANCH CIRCUIT IN THE FINAL FEE. APPLICANT HAD PREMADE CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65915	14041-10000-12915	1806 W 1ST ST	90732	15	018B189   263	7559013021	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	33.74327	-118.31547	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.2KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65916	17041-20000-15687	19147 W STRATHERN ST	91335	3	189B121   166	2104003026	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Issued	05/19/2017 12:00:00 AM	ADDRESS	34.21574	-118.551	pv1install roof mounted pv system sized 10.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65917	17041-10000-00784	6081 W CENTER DR STE 205	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	33.97811	-118.39245	T-24, PC FOR ENERGY. TI TO AN EXISTING HUMMUS FACTORY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1133 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65918	11041-20000-07022	1034 N COLE AVE	90038	4	144B185   820	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.08997	-118.32972	T.I. to existing building.  Install indoor general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65919	17041-20000-23360	5012 S SLAUSON AVE 1-28	90230	11	108B161   194	4217028004	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			07/11/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	33.99448	-118.40798	PLANCHECK FOR POWER AND ENERGY FOR (N) 3-STORY W/ MEZZANINE TYPE V-A 28-UNIT AFFORDABLE HOUSING APTS. FIRE ALARM VARIANCE HAS BEEN SUBMITTED.BUILDING PERMIT # 16010-20000-04830	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65920	16041-20001-23427	9131 N OAKDALE AVE #100	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.23697	-118.56716	07/18/2016 Changes to an approved set of plans. Changes have been made to fixture type and the receptacles are now shown on the floor plans. All changes have been reflected onto the Title 24 forms. *****Previous Work Description*****Plan check Title 24 only T.I. in existing office. Total area: 3,191 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65921	19041-10001-39915	11517 N BIANCA AVE	91344	12	213B129   250	2607011020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM			PC Approved	10/23/2019 12:00:00 AM	ADDRESS	34.2799	-118.51422	NEW ROOF MOUNTED 12.35KW PV SYSTEM WITH 38 PV PANELS AND OPTIMIZER AND ONE CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65922	18041-10000-15228	16908 W PARTHENIA ST	91343	12	195B133   472	2689018022	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/25/2018 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	12/28/2019 12:00:00 AM	ADDRESS	34.22835	-118.50086	T-24, PC FOR ENERGY. TI OF EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1673 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65923	10041-10000-01935	18355 S FIGUEROA ST	90248	15	063B201   204	7339008010	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Public Safety Only			02/03/2010 12:00:00 AM	02/04/2010 12:00:00 AM		Permit Finaled	06/08/2010 12:00:00 AM	ADDRESS	33.86489	-118.28185	New Fire Alarm System for a union hall.  P/C is for Power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65924	13041-10000-23065	234 S FIGUEROA ST	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Apartment			08/23/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.05578	-118.25359	TITLE 24 PLAN CHECK ONLY. OUTDOOR AREA. 4650 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65925	18041-10002-29423	1063 E 42ND ST	90011	9	114A209    90	5115022001	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2283.20	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.00767	-118.25697	"NO FEE DUE TO AB1414. DELTA ""1"" CHANGES TO APPROVED PLANS FOR RELOCATION OF THE PV PANELS ON THE ROOF. <<<PV2, NEW PV SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS IN A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW (72) MODULES AND OPTIMIZERS AND (2)10KW INVERTERS. TOTAL SYSTEM SIZE IS 20KWAC AND 23.4 KWDC.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65926	14041-10000-30748	22322 W BASSETT ST	91303	3	183B101   670	2024033013	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.19514	-118.61306	PV1 standard plan, 7.6kw system including (26) Sunpower spr327 modules , and (2) Powerone PVI-3.8 inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65927	19041-10000-53320	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	06/02/2020 12:00:00 AM		Permit Closed	09/30/2020 12:00:00 AM	ADDRESS	34.07666	-118.3805	TITLE 24 PLAN CHECK ONLY. SCOPE OF WORK INCLUDES ADDITIONAL CIRCUITS TO EXISTING SYSTEM AND ALTERATIONS TO LIGHTING FIXTURES. TOTAL AFFECTED AREA: 980 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65928	12041-10001-22405	4550 W PICO BLVD SUITE #301	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	chnages to approved set of plans. delta 1 changes. original pc under 10000#.Plan check power and energy for first time tenant. Ross retail store. Core and shell plan check under #07041-10000-11169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65929	12041-10001-01917	4220 W 3RD ST 102	90020	10	135B193   221	5503005022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			05/10/2012 12:00:00 AM			Plans on Hold	05/24/2012 12:00:00 AM	ADDRESS	34.06883	-118.30609	Modification to approved set of drawings.  Change to lighting, new feeder for water heater, reduce size of UPS and relocate circuits to other panel.    <<<Plan check power and energy TI for Plastic Surgery Center (Unit #102). New panels, equipment, and branch circuits. Existing service.>>    PER APPLICANT'S REQUEST THE PLANS WERE PLACED ON HOLD.  5/24/2012	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65930	12041-10000-21687	810 W DOWNEY WAY Room 105	90089	8	118-5A201  22	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	03/04/2013 12:00:00 AM	ADDRESS	34.01956	-118.28642	TENANT IMPROVEMENT TO EXISTING LABORATORY BUILDING (ROOM 105) EPC IS FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65931	12041-20000-17436	5031 N ALONZO AVE	91316	5	171B129   362	2182007002	RA-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM			PC Approved	07/26/2012 12:00:00 AM	ADDRESS	34.16167	-118.52046	T.I. for library, meeting room, and classroom.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65932	19041-10000-39500	110 E 9TH ST STE C0160	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Issued	10/22/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	T-24 PLAN CHECK FOR AN INTERIOR ALTERATIONS TO (E) OFFICE. FOR FEDEX OFFICE PRINT AND SHIP CENTER. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTALES AND CONTROLS. TOTAL AFFECTED AREA IS 1358 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65933	16041-20000-25823	7403 S LA TIJERA BLVD	90045	11	099B169   107	4104017043	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			07/21/2016 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	33.97043	-118.37984	Plan check for New Appartment Builidng 4 story 140 units mixed use (2) 2000A Service. Total area: 110,000 sq ft. Fire alarm variance has been filed.Note: Building permit has been issued under 13010-10000-02863	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65934	11041-20000-03500	17227 W VENTURA BLVD	91316	5	171B133   679	2258012022	[Q]C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/23/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	04/15/2011 12:00:00 AM	ADDRESS	34.16081	-118.50827	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR CHG OF USE FROM OFFICE TO DANCE STUDIO. EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65935	14041-20000-03833	11357 W TENINO AVE	90066	11	111B161   137	4217003014	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.00231	-118.41371	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZ E3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65936	17041-20000-08031	14720 W RINALDI ST	91340	7	213B149   249	2613017005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Issued	03/22/2017 12:00:00 AM	ADDRESS	34.28028	-118.45373	pv1install roof mounted pv system sized 10kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65937	14041-10000-24965	5824 N WILKINSON AVE	91607	2	174B165   149	2340014041	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.1764	-118.40404	PV1, INSTALL 10.2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(40) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65938	19041-20000-13460	10168 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	34.25508	-118.57961	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 800-amps. New service will backfeed existing and new distribution equipment.Note: Electrical plan check for the temporary service is under application number 19041-20000-13458	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65939	19041-10000-34039	410 S SPRING ST	90013	14	129A211    63	5149023013	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM			PC Info Complete	08/28/2019 12:00:00 AM	ADDRESS	34.04847	-118.24839	PC for T24 for a for gas meter room. Total affected area is 254 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65940	13041-10000-27306	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	33.79072	-118.29449	Remove and replace a piece of X-ray equipment.  Building is NOT a State Licensed Building per the Applicant.  NOT CHECKED FOR OSHPD3.  NO SUITE NUMBER PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65941	11041-10001-04593	6401 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM			PC Approved	09/07/2011 12:00:00 AM	ADDRESS	34.18624	-118.59778	MODIFICATION TO PREVIOUSLY APPROVED SET OF PLANS.  CHANGE FROM OVERHEAD SERVICE TO UNDERGROUND SERVICE.  <<<<<CHANGE OF USE FROM RETAIL TO GYM ( LA FITNESS )>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65942	15041-10000-29901	19851 W NORDHOFF PL #101	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.23624	-118.56649	PC for energy only.  Remove HID light fixtures and replace with new LED fixtures.Total area: 6188  sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65943	18041-30000-07081	418 N NORTON AVE	90004	4	141B189  1134	5522022023	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.07908	-118.3169	Plan check for new fire alarm system for 4 story 35 units. Total fire alarm devices 150 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65944	15041-20000-39323	10125 W PALMS BLVD 1-29	90034	5	120B165    94	4313001033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Apartment			11/20/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.0282	-118.40572	PV2. ROOFMOUNTED SOLAR SYSTEM ON APARTMENT BUILDING. SYSTEM SIZE: 40KW DC.NOTE: PERMIT FEES ARE $0 DUE TO SENATE BILL 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65945	16041-20000-05644	16101 W BLACKHAWK ST	91344	12	204B141   199	2668020010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.2584	-118.48286	Plan check for PV roof mounted system. System size: 6.0kW with 20 modules and 1 inverter(5.0kW) and 5 microinverter. System mix with microinverters and central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65946	15041-10000-07004	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			03/10/2015 12:00:00 AM			Verifications in Progress	08/03/2015 12:00:00 AM	ADDRESS	34.01768	-118.42494	PV2. Install 48.4 kW roof-mounted, utility-interactive PV system.  (2) Tripower 24000TL-US w/ 176 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65947	16041-10000-26947	3551 W OLYMPIC BLVD	90019	4	129B189   199	5092020026	C2-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.05271	-118.31699	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (OUTDOOR) 18656 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65948	17041-20000-16270	12841 N ADELPHIA AVE	91340	7	222B157   401	2513004008	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.30384	-118.42886	pv1install roof mounted pv system sized 6.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65949	12041-10000-00909	1625 W 190TH ST	90248	15	060B193   387	7351001024	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM			PC Approved	01/13/2012 12:00:00 AM	ADDRESS	33.85851	-118.30846	new offices/restrooms /storage inside a  warehouse buildingplan chk is for title 24 with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65950	17041-10000-11644	4560 W DORAN ST	90039	13	165B201    35	5593005031	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.15294	-118.27759	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 89300 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65951	15041-10001-18700	437 S BROADWAY	90013	14	129A211    47	5149026008	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM			PC Approved	05/11/2016 12:00:00 AM	ADDRESS	34.04875	-118.25034	"05/05/16changes to an approved set of plans. Changes include feeder size for PANEL ""GAC', changing feeder breaker size to 400A, changing load equipment on roof from 3 pole to 2 pole, and revising load calculation.NOTE: permit paid under Pcis#15041-10000-18700 Full plan check for an existing 4-story building; The main scope is for core/shell only, work include new HVAC units, minimum lighting and receptacle outlets. Note. Applicant comes in with a preprint check. plan checker need to add (20) circuits for final fee."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65952	13041-10001-14843	1701 E CESAR E CHAVEZ AVE 5TH FLR-SUITE 560	90033	14	130-5A221 204	5174007047	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.05126	-118.2173	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ONLY. HEALT CARE FACILITY. NO MEDICAL EQUIPMENT IS INSTALLED. RECEPTACLES WILL BE INSTALLED IN PATIENT CARE AREAS IN COMPLIANCE WITH ARTICLE 517. REMINDER: TITLE 24 PART 6 ENERGY PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65953	19041-10000-49513	2100 S WESTERN AVE	90732	15	012B193  1140	7460004015	RD2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2973.00	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	33.72554	-118.3111	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
65954	14041-20000-22353	9348 N MCLENNAN AVE	91343	12	198B133   210	2687010018	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/23/2014 12:00:00 AM	ADDRESS	34.24071	-118.50064	FEE TOTAL IS ZERO DOLLARS PER SENATE BILL 1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.(49) KYOCERA KD255GX MODULES(2) AURORA PVI-5000 TRANSFORMERLESS INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65955	17041-10000-21942	1708 W BEVERLY BLVD	90026	13	135A207   198	5153001004	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM			Reviewed by Supervisor	07/12/2017 12:00:00 AM	ADDRESS	34.06453	-118.26605	PC FOR TEMPLE. BUILDING# 12010-10000-01634. NEW 600A SERVICE AND ASSOCIATED LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65956	18041-20000-46948	13269 W SEVILLANA WAY LOT 9	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.3153	-118.42262	Plan check for PV roof mounted system,system size: 1.68KW with 7 PV Modules and7 microinverters. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65957	17041-10000-18718	1350 N WESTERN AVE	90027	13	147A193   205	5544032013	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM			Reviewed by Supervisor	09/13/2017 12:00:00 AM	ADDRESS	34.09572	-118.30904	PC for power and energy for new 7 story building with 1 subterrean basement. PC for new 4000A 480/277V service, new panels, new branch circuits and equipment. Total sqft  349698 with no outdoor lighting. Building #16010-10000-05432.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65958	18041-20000-37708	3604 N LOWRY ROAD	90027	4	154-5A203 261	5592007043	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.11674	-118.27715	pv1install roof mounted pv systm sized 8.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65959	09041-20002-17341	1616 N LA BREA AVE	90028	13	147B181   377	5548012046	R4-2	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Apartment			03/19/2014 12:00:00 AM			PC Info Complete	04/17/2014 12:00:00 AM	ADDRESS	34.1002	-118.34456	(((3/19/2014- CHANGES MADE TO APPROVED SET OF PLANS. ADDED CIRCUITS AND CHANGES TO LIGHTING. **ORIGINAL PERMIT WAS NOT PULLED ON THIS PROJECT. NO PERMIT TO BE OBTAINED UNTIL THE ORIGINAL [09041-10000-17341] IS PAID**)))New 56-unit, 4 sotry mixed-use building.  Power and energy.  A variance has been filed to separate the fire alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65960	14041-10001-16549	450 S WESTERN AVE	90020	10	135B193   649	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.06562	-118.30887	[[[[ 9/18/2014   SUPPLEMENTAL PLANCHECK DUE TO MAJOR CHANGES TO SLD AND LOAD SCHEDULES]]]]plan check for power and energy. not methane. BLDG#14016-10-04268:TENANT IMPROVEMENT, MARKET INCLUDING MEAT AND SEAFOOD DEPARTMENT AND KITCHEN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65961	16041-20000-24766	10136 W HOLLOW GLEN CIR	90077	5	156B153   152	4382025***	RE15-1-H-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	PIN	34.12335252	-118.44234551	Install a roof-mounted solar array on a SFD. (18) 335W pv modules. MSP is 225A. 6kw Ungrounded system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
65962	14041-10001-01284	7645 W DAY ST 1-4	91042	7	204A197   186	2558034033	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.25464	-118.29945	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65963	19041-20000-14301	444 S FLOWER ST GND FL	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	T24 PLAN CHECK FOR EXSITING HIGH RISE COMMERCIAL BUILDING. LIGHTING REMODEL FOR 2 EXISTING ALL GENDER RESTROOMS AND EXISTING STORAGE ROOM. INSTALLING 2 5KW WATER HEATERS IN THE RESTROOMS. TOTAL SQUARE FOOTAGE = 464SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65964	18041-10000-12968	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	PC FOR NEW SIGN (1) DD.06 DIGITAL DISPLAY AT NORTHWEST PLAZA ABOVE ANCILLARY TEAM STORE ENTRY. FOR TITLE 24 ENERGY ONLY. B# 18048-10000-00700	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65965	18041-10000-05471	15210 W ANTELO PL	90077	5	159B145   585	4378005010	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2018 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.1288	-118.46136	PC for power for single family dwelling altererations. Installing new service, service equipment, panel, receptacles, lighting and equipment. Partial Permit was issued under Building Permit: 17010-10000-02982 & 16014-10000-01431	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65966	18041-10000-15922	15477 W VENTURA BLVD SUITE 300	91403	5	168B145   725	2261039008	C4-1L, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.15484	-118.47126	FULL PC FOR A TENANT IMPROVEMENT TO EXISTING MEDICAL OFFICE, OSHPD 3 MEDICAL LICENSED PRIMARY CARE CLINIC. SCOPE OF WORK INCLUDES NEW LIGHTING, PANELS AND CIRCUITS. TOTAL SQ. FT. 5715.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65967	17041-20000-00180	10601 W WASHINGTON BLVD	90232	5	117B165   262	4208009049	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	11/17/2018 12:00:00 AM	ADDRESS	34.0175	-118.40491	new fire alarm system 520 devices and (1) facp to a seven story mixed use building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65968	15041-20000-41649	2000 S AVENUE OF THE STARS	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.05868	-118.41546	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (MECHANICAL ROOM SPACE). SCOPE INCLUDES NEW INDOOR LIGHTING. TOTAL AREA IS 3300 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65969	17041-10000-36227	944 E PICO BLVD # 5	90021	14	123A211   265	5132018034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	11/08/2017 12:00:00 AM	ADDRESS	34.03051	-118.24925	INTERIOR ALTERATIONREPLACE HID LUMINAIRES WITH LED      TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65970	17041-20001-42741	18800 W COVELLO ST	91335	3	186B121   300	2118004021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.20737	-118.54276	expeditepv1install roof mounted pv system sized 5kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65971	13041-10000-33791	11100 W SANTA MONICA BLVD	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			PC Approved	12/04/2013 12:00:00 AM	ADDRESS	34.04726	-118.44465	Tenant improvement for a high rise, 8th floor, suite # 850 , title 24 and emergency lighting, .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65972	14041-10000-17268	840 S SPRING ST	90014	14	127-5A209 228	5144016048	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.04233	-118.25416	TENANT IMPROVEMENT IN A RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65973	14041-10001-10357	520 S VIRGIL AVE	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.06457	-118.28687	CHANGES TO APPROVED (power and energy) : CHANGING PHYS THERAPY ROOM TO XRAY room and storage/corridor. Changes on plan include occupancy sensors for offices and redundant grounding note for receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65974	11041-10000-05160	16134-16136 W NORDHOFF ST STE. E-STE. F	91343	12	195B141     4	2672001011	(Q)C2-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM			PC Approved	03/23/2011 12:00:00 AM	ADDRESS	34.23547	-118.48436	T-24 FOR AN EXISTING RETAIL, SUITE E DIVIDED INTO SUITE E & F.  OVER THE COUNTER PLAN CHECK.    <<<<<<<<<<<T-24 FOR SUITE F ONLY, SUITE E WILL BE ON A SEPERATE T-24>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65975	16041-20000-25717	5755 W 96TH ST	90045	11	093B169   134	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Info Complete	11/09/2016 12:00:00 AM	ADDRESS	33.94955	-118.38214	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVENET FOR NEUTROGENA MANUFACTORING. ( 3 OF 3 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65976	13041-10000-21068	7461 W MELROSE AVE	90046	5	141B181   502	5526011014	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.08375	-118.35261	"Permit pulled under 13041-10000-03029, PC for energy only per inspector's request. retail to restaurant. with emergency lights. 1 story. ""COMPLY WITH DEPARTMENT ORDER effective date 6/27/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~NO: 98116  -- Building/Electrical/MechanicalINVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issuedwith effective date 06/27/2011 by Inspector JOHN MATTILLO at phone# (213)252-3035.  CEIS Case Number is 389432."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65977	17041-10000-32052	1354 E APPLETON WAY	90291	11	114B149  1118	4244025027	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	09/23/2017 12:00:00 AM	ADDRESS	34.00455	-118.45362	PC for 3.8kW rooftop solar system with 12 solar panels and optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65978	19041-20001-28507	19626 W VICTORY BLVD	91335	3	180B117   894	2132016017	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.18634	-118.56096	CHANGES TO APPROVED SET REMOVING AC DISCONNECT AND CHANGES IN BREAKER SIZE.<<<PV1.  Install 4.725 kW DC / 3.8 kW AC roof mounted grid tied PV system and 9.8 kWh energy storage system. (15) modules with 3.8 kW rated inverter.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65979	17041-20000-28040	14924 W NAVARRE WAY	91342	7	219B149   980	2611046066		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29435	-118.45583	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
65980	12041-20000-00744	14925 W MAGNOLIA BLVD	91403	2	172-5A149 270	2250021001	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.00	Electrical	Electrical	Apartment			01/11/2012 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.16501	-118.45824	49 units apartment building Request for Modification to separate Fire Alarm System filed 03.12.12	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65981	18041-10000-31090	837 N SPRING ST #101	90012	1	135A215   314	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	PIN	34.06296813	-118.23676788	Plan check for T24 only, TI on (E) suite 101 , total area 5,869 sq. ft. Emergency lights and exist signs are existing to remain. (B# 18016-30000-16739)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65982	12041-10000-26263	8103 W BEVERLY BLVD	90048	5	138B177   405	5514007051	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM			PC Approved	11/01/2012 12:00:00 AM	ADDRESS	34.07625	-118.3661	REMODEL EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65983	17041-10003-00340	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/27/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.16326	-118.37388	Supplemental application for removing equipment from single line diagram all changes under delta 10. (((Full PC for power and energy. New mixed use housing complex -297 dwelling-unit 6 levels of apartment on top of on grade market (core and shell)  above 2 -level of type I construction parking garage.  Scope includes three new services/distribution boards(2500A & 1600A), new panels, new circuits, and new lights for two structures. Total affected area is 266331 Sq. Ft.  B#16010-10000-04268@@@@BUILDING COVERS TWO ADDRESSES:  5101 LANKERSHIM BLVD AND 5130 KLUMP AVE.@@@)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65984	17041-20004-29102	15253 W GOLDEN CT	91342	7	219B145   688	2611041026	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.29481	-118.46533	03/27/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta D. The battery backup system has been removed as is now PV only. PV system has also changed.01/30/2018 Changes to an approved set of plans. There has been an addition of (1) PV module to the PV system. Inverter size has remained the same. 11/21/2017 CHANGES TO APPROVED SET. RELOCATING THE ENERGY STORAGE SYSTEM*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6 kWac and consists of (1) inverter, (19) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65985	14041-10000-35399	8820 N BAIRD AVE	91324	12	195B125   486	2770016030	[T][Q]MR1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.23151	-118.53723	Title 24 plan check only.  Total area = 5,120 sq. ft.Retrofit existing lights to LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65986	19041-20001-06858	8700 S PERSHING DR	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Expedited plan check fee.PV2.  Install 120.96 kW DC / 108.55 kW AC roof mounted grid tied PV system.  (336) modules with (4) 30 kW rated string inverter.System 2 of 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65987	15041-10001-32635	811 W 7TH ST 11TH FLR	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.04908	-118.25911	Change to approved set by modifying all exist signs with (1) normal and (1) emergency circuit on the lighting floor plan. Panels also being updated with new modification; All changes are under delta-1 only.(((T-24. PC FOR ENERGY ONLY.  FULL FLOOR TENANT IMPROVEMENT AT THE 11TH FLOOR OF AN EXISTING OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTING AND TWO NEW PANELS. TOTAL AREA IS 7738 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65988	15041-10000-31318	777 S FIGUEROA ST #2555	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	34.04828	-118.26116	Energy plan check for an office (#2555)  T.I loacted in the 25th floor of a high rise building; Scope includes new lighting, receptacles and (1) equipment; Total 1800-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65989	14041-20001-17835	1220 W HARRY BRIDGES BLVD	90744	15	027B201   208	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	33.77024	-118.27673	[[1/27/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES ARE CLOUDED. DELTA 1 CHANGES. ]]]Plan check for power only.  Remove and replace ATS, generator, VFDs, pumps, and motors in existing industrial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65990	12041-10000-01392	11430 W WOODBINE ST	90066	11	117B157   202	4249002900	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00, 2717.02, 2719.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	03/21/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.018	-118.42896	TI IN AN EXISTING RESTROOM AND A NEW STORAGE AREA. PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65991	14041-10000-14689	621 S WESTERN AVE # G-03	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.0628	-118.30928	PLANCHECK FOR POWER AND ENERGY FOR SUPER H-MART. TENANT IMPROVEMENT. EXPANDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65992	11041-20000-16998	5601 N DE SOTO AVE MOB II	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Expired	11/06/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check UPS equipment, new ckts, and HVAC equipment for IT rooms at Kaiser MOB II	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
65993	19041-10000-04450	4820 S ALLA ROAD	90066	11	105B157   536	4223008005	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM			Corrections Issued	02/06/2019 12:00:00 AM	ADDRESS	33.98277	-118.42936	PC FOR NEW FA SYSTEM IN A NEW 2-STORY OFFICE BUILDING (OFFICE BUILDING 1 of 3). SCOPE INCLUDES FA PANEL, ANNUNCIATOR, CELL COMMUNICATOR AND 41 DEVICES. DUCT SMOKE DETECTORS, TAMPER SWITCH, FLOW SWITCH AM SMOKE FIRE DAMPERS ARE CONTRACTED BY OTHERS AND NOT PART OF THIS BATTERY CALCULATIONS. Bldg permits for the (3) separate buildings are under the following permits:16010-10000-0393516010-10000-0393616010-10000-03937Void (PC only) per applicant David Zohn request. Permit finaled under 19041-10000-13133	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65994	18041-20001-37014	10642 N BALBOA BLVD UNIT A	91344	12	207B133   597	2684001024	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Issued	11/28/2018 12:00:00 AM	ADDRESS	34.26355	-118.50206	Permit for additional circuits to cover required inspection fees.  Plan check for Title 24 Part 6.((((1) 20A CIRCUIT FOR TI)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65995	12041-10000-26547	621 S WESTERN AVE SUITE 104	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	TI: FOR (1862sqft) RETAIL SHOP, NEW FLOORING, CEILING, NON-BEARING PARTITIONS.  NO CHANGE OF USE. full plan chk	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65996	18041-10000-37990	1417 W WASHINGTON BLVD	90007	1	126A201   123	5056015003	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.04019	-118.28699	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65997	16041-20000-27409	7650 N VAN NUYS BLVD	91405	2	186B149    60	2215028018	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.2099	-118.44854	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR STORAGE.  220 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65998	18041-10000-39414	7575 N SAN FERNANDO ROAD	91505	2	186B177   565	2466036***	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.20799	-118.35512	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
65999	16041-10000-33201	2186 E 99TH PL 101-301	90002	15	093A217   272	6049019***	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	33.94694	-118.23303	PC for a power only for a New 3-story 15 unit apartment E4 Bldg 5-1 (Bldg. 3 of 8).  Scope includes a new 800A 120/208V 3 phase 4 wire service/distribution board. One plan is submitted for multiple apartment buildings. B#16010-10000-10000-02986	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66000	15041-20000-05035	22870 W TRIGGER ST	91311	12	201B097    67	2724008043	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2015 12:00:00 AM	03/03/2016 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.248	-118.62556	GROUND MOUNTED PV SYSTEM. SYSTEM SIZE 5 KW AC.(18) SOLAR WORLD SQ 315(1) ABB PVI 5000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66001	14041-20000-32513	11515 N SPROULE AVE	91331	7	213B161   721	2532006010	A2-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	01/02/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.27889	-118.40731	pv1 install roof mounted pv system sized 10.0kw interconnected with msp.(34) sunpower 327w modules, (2) powerone pvi 5k transformerless inverterNote: solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66002	16041-10000-25122	2501 S WEST VIEW ST	90016	10	123B181   758	5049008056	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Issued	09/13/2016 12:00:00 AM	ADDRESS	34.03352	-118.34817	PV2. NEW ROOFTOP SOLAR SYSTEM ON EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE IS 13.3 KW AC(62) MODULES-SOLARWORLD SW 260 POLY(62 ) ENPHASE M215(1) 125A LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66003	19041-10000-42543	937 E 113TH ST	90059	15	087A209   276	6072022022	R2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	33.93199	-118.25729	NEW ROOF MOUNTED PV1 INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS.INSTALLATION INCLUDES 13 MODULES (CANADIAN SOLAR), 1 INVERTER (SE3800H-US), 1 OPTIMIZER (P320) SERVICE SIZE: 4.03 KW DC, 3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66004	16041-30000-29131	2049 S CENTURY PARK EAST 30th FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing space High-rise building men and women restroom 30th Floor. Total lighting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66005	18041-20000-44760	7921 N CANOGA AVE #C & D	91304	3	189B105   192	2110005015	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.21414	-118.5977	Restaurant tenant improvement.  Title 24 Part 6 plan review.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66006	19041-20001-11150	212 N ARDEN BLVD	90004	4	138B189   623	5515017008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.07504	-118.32584	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET SINGLE LINE, CHANGE TO MAIN PANEL AND TO FEEDER SIZES, CLOUDED CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66007	19041-20000-29065	22620 W AVENUE SAN LUIS	91364	3	171B097   517	2075010011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.16541	-118.61868	Plan check for PV roof mounted system, PV system size: 10.88kW with 34 PV Modules and 1 inverter(10kW) with LG battery 9.8kWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66008	16041-10000-00016	7224 S VERMONT AVE	90044	8	102B197  1190	6020001035	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	33.97406	-118.2913	New fire alarm system in existing grocery store.  Total system size = 44 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66009	15041-10000-34459	11100 W SANTA MONICA BLVD STE 450	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2020 IN SUITE 450.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66010	12041-20000-23750	342 S LA BREA AVE	90036	4	135B181   300	5507008018	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.06762	-118.34382	T-24 lighting plan check for remodeled space.  CHANGE OF USE FROM RETAIL TO TAKE-OUT RESTAURANT [AREA ~ 242 SQ FT] (JUICE BAR) WITHIN EXISTING MEDICAL OFFICE AND RETAIL. NO ALCOHOLIC SALE OR CONSUMPTION ON SITE. NO SEATING ON PREMISES OR ON-SITE CONSUMPTION. NO CHANGE IN PARKING. MAXIMUM 4 EMPLOYEE ON SITE. HOURS OF OPERATION LIMITED FROM 7:00 AM TO 11:00 PM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66011	14041-10001-20803	9301 N TAMPA AVE Ste 146	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM			PC Approved	01/08/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Change to approved set of plan per inspector request apply to Delta 9 only((((TI to (E) commercial restaurant space (yogurt shop).  Plan check for energy.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66012	16041-20000-04860	15910 W VENTURA BLVD 18th fl	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.15561	-118.47969	Plan check Title 24 only for existing highrise building on 18th floor corridor. Total area: 1,030 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66013	19041-10000-26594	679 S HARVARD BLVD	90005	10	132B193   237	5093019019	R3P-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	02/27/2024 12:00:00 AM		Issued	02/27/2024 12:00:00 AM	ADDRESS	34.06051	-118.30444	Full PC for power and energy provide new 1200A 480/277V 3 Phase 4 wire service. Scope of work includes panels, equipments and lighting. B#19010-100000-01508	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66014	18041-20000-15867	6421 E YORK BLVD	90042	14	153A233   120	5493015017	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.11432	-118.18069	Plan check for power and energy. Project site is a new commercial building (restaurant). Work includes a new 600 Amp service and a total lighting area of 8,887 sq. ft.Note: Building applications has been generated under 18010-20000-01843Note: Plan check only, Permit shall be pulled under supplemental application 18041-20001-15867	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66015	15041-10000-17976	2753 W WAVERLY DR BLDG 8	90039	4	151-5A207 233	5438025***	RD2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.10855	-118.26334	NEW DEVELOPMENT FOR MULTI BUILDING TOWNHOUSES 600 AMP SERVICE.  THIS IS BUILDING 3 OF 5.  PLAN CHECK FOR POWER AND ENERGY.  EACH BUILDING HAS ITS OWN SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66016	13041-20000-11130	2232 S DUXBURY CIR	90034	5	126B165   383	4309014002	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.04288	-118.39626	PV1 1 STORY SINGLE FAMILY DWELLING. 42 MODULES AND 2 INVERTERS. TOTAL SYSTEM SIZE: 12.15 KW. [INVERTER: (1) SUNPOWER 5000P-TL-1 & SUN POWER SPR-7000M] [SOLAR MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66017	17041-30000-44596	12775 W MILLENNIUM 4-130	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	33.97584	-118.4171	Plan check for power and energy. Project site is an existing retail space. Project scope is a core and shell. Total lighting area = 2,780 sq. ft.Note: Building application has been generated under 17016-30000-36613	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66018	16041-20000-16608	4323 N SHADYGLADE AVE	91604	2	165B165   538	2367002017	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.14933	-118.40203	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (2) inverters, (31) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66019	13041-10000-27554	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	Replace existing 365kW generator with new 800kW generator. Replace existing distribution board (like for like), two automatic transfer switches and emergency distribuition boards. No changes to existing load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66020	15041-10001-20699	12020 W WILSHIRE BLVD	90025	11	126B145   137	4263003012	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	ADDRESS	34.04468	-118.46646	"Change to approved set by adding fixture ""B"" on the floor plan. application is for plan check only, permit shall be pulled under original application.(((Energy plan check for a 2-story building; Scope includes new light in a total area of 1159-SQ feet.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66021	17041-20001-24776	8500 N BALBOA BLVD SUITE #170	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM			PC Approved	12/07/2017 12:00:00 AM	ADDRESS	34.22485	-118.50045	12.7.2017 - Plan check for changes to approved set. Update feeders >100A from copper to aluminum. Update fault current study (sheet  E-921) to show aluminum feeders. Add aluminum fixture schedule (sheet E-901). Changes clouded delta 13. Note: changes to lighting fixture schedule ignored for this plan check. ======Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area of 96,648 sq. ft.Note: Building application has been generated under 17016-10000-15426	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66022	10041-10001-10645	4020 S BUCKINGHAM ROAD BLDG 1	90008	10	117B181   723	5032004010	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Park - Leimert Park	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			10/14/2011 12:00:00 AM			PC Approved	10/14/2011 12:00:00 AM	ADDRESS	34.01383	-118.34223	Delta 7 modification to previously approved set of plans to show installed feeder details for apartment units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66023	14041-20000-04601	14441 W NORDHOFF ST	91402	6	198B149   529	2639010008	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Expired	05/08/2020 12:00:00 AM	ADDRESS	34.23555	-118.44749	T24 PART 6 ENERGY FOR (E) SINGLE-STORY CHURCH. SCOPE OF WORK < 400A. PLAN CHECK FOR ENERGY ONLY. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 905 SQ FT FOR INDOOR, AND 1325 SQ FT FACADE LIGHTING FOR OUTDOOR. PLAN CHECK AND PERMTI UNDER SAME APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66024	19041-10000-35710	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	33.97954	-118.42015	PC for  FA system for a new TI. Scope includes new Facp, 4 power suplies and  180 Devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66025	12041-20000-21000	8710 N ENCINO AVE	91325	12	195B129   422	2768015014	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2012 12:00:00 AM			Reviewed by Supervisor	11/08/2012 12:00:00 AM	ADDRESS	34.22897	-118.51557	Plan check for PV system. SFD. 11.04kW. PROJECT HAS BEEN ABANDONED. CHANGE OF CONTRACTOR. New application on 12041-20000-25307.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66026	19041-20000-27148	20746 W SCHOENBORN ST	91306	3	192B109   719	2780006059	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.22084	-118.58575	Plan check for a PV1 roof-mounted PV system. System size is 4.725 kWdc/7.6 kWac and consists of (1) inverter, (15) modules, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66027	11041-10000-16443	5730 S PALOMA AVE	90011	9	108B205  1049	5103014007	MR1-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	33.98991	-118.26195	Single story commercial building.  New 600 amp service.  Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66028	14041-10000-24573	11301 W OLYMPIC BLVD #106	90025	11	126B153  1060	4260002032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	PIN	34.03822251	-118.44166899	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. NO CHANGE IN OCCUPANCY. 476 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66029	13041-10000-02084	1116 E 12TH ST	90021	14	123A213   200	5132016027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM			PC Approved	05/03/2013 12:00:00 AM	ADDRESS	34.03085	-118.2472	SINGLE STORY BUILDING.  TI FOR 3 TENANT RETAIL SPACE.  T24 INDOOR AND OUTDOOR LIGHTING.  OCCUPANT LOAD LESS THAN 50, NO EMERGENCY LIGHTING REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66030	11041-20001-12487	5750 W WILSHIRE BLVD 2nd Floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM			PC Approved	09/19/2011 12:00:00 AM	ADDRESS	34.06227	-118.3542	Revision to approved plans. Changes to floor layout and T24 calculations. Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66031	14041-10000-28498	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.06086	-118.27891	300 device fire alarm system for an existing 11 floor hotel building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66032	19041-10000-47196	4717 N VINCENT AVE	90041	14	159A225    24	5689030017	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Issued	11/15/2019 12:00:00 AM	ADDRESS	34.13163	-118.20319	NEW ROOF MOUNTED 4.88KW PV SYSTEM WITH 16 @ (305W) PV PANELS AND OPTIMIZER AND ONE 3.8KW CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66033	12041-10000-19978	716 N HIGHLAND AVE	90038	4	141B185   470	5524011026	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM			PC Approved	08/23/2012 12:00:00 AM	ADDRESS	34.08412	-118.33839	T.I. to an existing restaurant with less than 99 occupants and load is less than 400A, per applicant.  PLAN CHECK ONLY for T-24, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66034	18041-10000-37747	1019 S GAYLEY AVE	90024	5	132B149    59	4363025010	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.06148	-118.44779	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT OF MEDICAL OFFICE BUILDING TO CHANGE OUT FINISHES, UPGRADE ACCESSIBILITY, REMOVE AND ADD NON BEARING PARTITIONS.  CHANGE OUT DOORS. - TOTAL AFFECTED AREA = 3327 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66035	14041-10000-16983	7872 N VAN NUYS BLVD #A	91402	6	189B149   646	2212028012	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.21445	-118.44622	Title 24 plan check only.  Total area = 13,704 sq. ft.TI to new retail space including lighting, outlets, and panels.(total connected load < 400A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66036	17041-20000-38865	1999 S AVENUE OF THE STARS Floors 16-17	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/27/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only. Project site is two floors of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 6,141 sq. ft.Note: Building application has been generated under 17016-10000-27850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66037	17041-20001-07886	4320 N VANTAGE AVE	91604	2	165B165   571	2367004028	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.1493	-118.39743	expeditepv1install roof mounted pv system sized 11kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66038	14041-20000-35673	947 N NOLDEN ST	90042	14	156A227   388	5478026001	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2014 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.12048	-118.19489	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service pannel.(12) Sunpower E20/327 Panels(1) Power One PVI 3.8 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66039	14041-20000-25559	1680 N VINE ST	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/17/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	FACADE LIGHTING OF HISTORIC HIGHRISE. PLAN CHECK FOR T24 OUTDOOR LIGHTING ONLY. FACADE AREA  ABOUT 32K FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66040	12041-20000-13799	2706 W WILSHIRE BLVD	90057	1	133-5A201  94	5141011016	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	06/14/2012 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.06093	-118.28296	New fire alarm system for Chuck E. Cheese's (suite 397)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66041	14041-10000-32937	726 S SAN PEDRO ST	90021	14	126A213   262	5146033042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	PIN	34.03988908	-118.24715314	Energy plan check in a commercial area by replacing HID to LED fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66042	18041-10001-07404	5455 W HOLLYWOOD BLVD	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.10193	-118.30881	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES CHANGES TO LIGHTING LAYOUT ONLY. THIS IS PLAN CHECK ONLY!!PLAN CHECK FOR T24 ONLY, PC FOR TENANT IMPROVEMENT TO (E) RETAIL STORE.TOTAL AFFECTED AREA 6054 SQ.FTB#18016-10000-06120	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66043	19041-20000-35666	543 E 31ST ST	90011	9	118-5A207 256	5128014019	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.01807	-118.26431	Plan check for PV roof mounted system, PV system size: 3.6KW  DC, 3.0KW AC with 12 PV Modules and 1 inverter(3KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66044	15041-10000-18807	1036 S NORTON AVE 1-4	90019	10	129B189   201	5081010043	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.05283	-118.32105	NEW FIRE ALARM SYSTEM TO AN (E) 3 STORY APARTMENT BUILDING. 115 FIRE DEVICES AND 1 FIRE ALARM CONTROL PANEL 2 COMMUNICATION DEVICES. .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66045	17041-20001-46555	20653 W CELTIC ST	91311	12	210B109    95	2707033014	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	01/08/2018 12:00:00 AM	ADDRESS	34.27108	-118.58384	expeditepv1install roof mounted pv system sized 10kw interconnected with msp.this system is an addition to an existing pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66046	13041-10000-36253	11272 N ESKO AVE	91342	7	210B181    33	2550003025	A2-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Expired	04/05/2016 12:00:00 AM	ADDRESS	34.27493	-118.34728	PV1, Install 7.25 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 3800A-US. (29) Modules: Trina Solar TSM-250PA05.18.(29) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66047	19041-10000-21193	10300 W VENICE BLVD 1-6	90232	5	117B165    21	4208005038	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.02072	-118.40287	"TI IN A NEW 18'-0""x 13'-0"" STORAGE & 13'-0""x 3'-10""TRASH ENCLOSURE AT (E) GROUND LEVEL GARAGE OF APARTMENT BLDG. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 19016-30000-08103"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66048	15041-30000-42257	13123 N CRANSTON AVE	91342	7	222B161    66	2512029074	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.3087	-118.41607	Addition of new roof mounted solar PV array to existing roof mounted solar PV system on existing single family dwelling.  Total system size = 6.6 kWac (3 kWac new).  Addition of one inverter to existing single inverter system (two inverters total).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66049	13041-10000-30034	5532 N MAMMOTH AVE	91401	4	174B157   707	2247001012	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Expired	11/30/2015 12:00:00 AM	ADDRESS	34.17124	-118.43219	PV1.  Install 9 kW DC roof-mounted photovoltaic system interconnect with main service panel.  Fronius IG PLUS V 7.5.  36 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66050	14041-10000-11462	5300 N LANKERSHIM BLVD 103	91601	2	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.16715	-118.37571	PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT RESTAURANT. (BLDG#: 13014 10 02499 addition - shell .  14016-10-08204 BLDG application for tenant)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66051	14041-20000-28000	6616 S 3RD AVE	90043	8	102B189   325	4008003012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Expired	11/24/2016 12:00:00 AM	ADDRESS	33.97869	-118.32053	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66052	15041-10000-35794	900 N ALAMEDA ST CR5	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	03/29/2016 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR POWER AND ENERGY. INSTALL UPS, POWER DISTRIBUTION AND LIGHTING FOR NEW COMPUTER ROOM. 4 * 500 KVA UPS MODULES AND 4 POWER DISTRIBUTION UNIT 1000KVA EACH. TOTAL AREA 12940 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66053	16041-20001-08768	1500 N GILCREST DR	90210	4	147B165   360	4352009054	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.09796	-118.40202	RSES expedited plan check per applicant request.  PV1.  Install 20.0 kW AC roof-mounted PV system.  (2) 10000 W inverters w/ (68) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66054	13041-10000-15200	13308 W VALLEYHEART DR 1-26	91423	4	165B157  1212		R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Apartment			06/11/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.14919	-118.4231	FA FOR new 26 UNIT APT. 4 story over 1 parking level. 119 devices and 1 facp and 1 annunciator and 1 remote power supply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66055	10041-20002-17057	825 E 4TH ST 1-53	90013		127-5A215 174	5163011028	M3-1		Central City North	Historic Cultural			Electrical	Electrical	Apartment			04/25/2012 12:00:00 AM			PC Approved	04/25/2012 12:00:00 AM	ADDRESS	34.0435	-118.23728	revision A2 change kithcen lighting fixtures and feeders from al to cu on main swbds	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66056	13041-10000-26141	920 W DOWNEY WAY	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.02063	-118.28879	This is a medium voltage  over 200 feet of cale pulling with man holes. 4800 volts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66057	11041-20000-05771	16005 W SHERMAN WAY	91406	6	183B141    86	2206035033	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM			PC Approved	04/01/2011 12:00:00 AM	ADDRESS	34.20138	-118.48171	Plan check T24 Energy/Emergency lighting TI (indoor and outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66058	15041-20001-06667	1079 N CARRARA PL	90049	11	141B137   217	4493018045	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.07901	-118.49114	FEE EXPEDITEPV1 SFD. TOTAL SYSTEM SIZE 13.6KW AC USING 2 CENTRAL INVERTER SYSTEMS. SYSTEM USES POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66059	15041-20000-38389	11821 W GWYNNE LANE	90077	5	153B141   106	4378037078	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2015 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.11581	-118.47468	PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel.(44) SOLARWORLD SW285 Modules(2) SMA America SB6000 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66060	11041-20000-02180	12100 W WILSHIRE BLVD #150	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.0438	-118.46755	T.I. to existing high rise building of 1st floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66061	15041-10000-13004	8530 S AIRPORT BLVD	90045	11	096B169   509	4125008800	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	33.96025	-118.38519	NEW FUEL CELL GENERATION 500KW SYSTEM.  PLAN CHECK FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66062	19041-10000-13242	827 N LACHMAN LANE	90272	11	129B121   298	4419006029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.0504	-118.54545	Installing two new panel (200 A) and two equipments (batteries), to an exisiting PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66063	13041-10001-23508	23752 W LADRILLO ST	91367	3	171B093   523	2047004016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM			Reviewed by Supervisor	09/04/2013 12:00:00 AM	ADDRESS	34.16417	-118.64296	PLAN CHECK ONLY. EXPEDITED PLAN CHECK PER APPLICANT REQUEST. PV1 - INSTALL ROOF MOUNTED PHOTOVOLTAIC SYSTEM  INTERCONNECT WITH MAIN PANEL. DERATED MAIN. SYSTEM SIZE: 13.72KW  UNGROUNDED AURORA INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66064	18041-10000-31266	1011 S OCEAN FRONT WALK 1-2	90291	11	108A143   271	4226003004	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Info Complete	08/16/2018 12:00:00 AM	ADDRESS	33.98976	-118.47604	"VOID - LOST OF PLANS RE PLAN CHECK UNDER APPLICATION # 19041-10000-02104. PLAN CHECK FOR T24 ONLY, T.I. TO AN (E) RETAIL SPACE ""SNEAKERNSTUFF"" OF MIXED USE BUILDING. 1ST FLOROR URM BUILDING. TOTAL AREA UNDER THE SOW: 6,433 SQ.FT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66065	15041-20000-20684	9506 N PENFIELD AVE	91311	12	198B113    27	2761027017	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.24324	-118.56945	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW. STANDARD CENTRAL INVERTER PLAN. nonstandard plan. system uses power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66066	17041-20000-43979	16738 W CALAHAN ST	91343	12	198B137   941	2687019006	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Expired	04/07/2024 12:00:00 AM	ADDRESS	34.23652	-118.49713	pv1install roof mounted pv system sized 10.4kw intercomnnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66067	11041-20002-17463	5404 S JANDY PL 1st & 2nd-floor	90066	11	105B161   885	4211006004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			PC Approved	05/23/2012 12:00:00 AM	ADDRESS	33.98159	-118.41622	Entry Garden revisionsEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66068	19041-10000-16536	5161 N LANKERSHIM BLVD #250	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.16452	-118.37469	FULL PC POWER AND ENERGYFOR  TENANT IMPROVMENT TO SUITE 250 FOR SINGLE TENANT OCCUPANCY NO CHANGE TO USE. AREA SCOPE OF WORK 30,000SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66069	17041-20000-15939	16000 W ARMINTA ST	91406	6	189B141   175	2206008018	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM			PC Info Complete	09/20/2018 12:00:00 AM	ADDRESS	34.21377	-118.48185	UPS FACILITY ADDITION.BUILDING PERMIT UNDER 17016 20000-11973.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66070	10041-10000-09180	7338 N BALBOA BLVD	91406	6	186B133   874	2226030017	(T)(Q)RD1.5-1	South Valley	Reseda - West Van Nuys			1275.10	Electrical	Electrical	Apartment			05/17/2010 12:00:00 AM	05/17/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.20407	-118.50092	Fire sprinkler monitoring system for 2 story appartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66071	18041-30001-16497	8905 W VENICE BLVD 109	90034	5	123B169  1508	4312011036	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	ADDRESS	34.02929	-118.38914	This is plan check only to replace a lost approved set of plan. Permit under 18041-10000-16497.<<Energy plan check for a take out restaurant. Scope includes new lighting and equipment. Total area is 1014-SQ FT.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66072	19041-20000-12970	9140 N LURLINE AVE	91311	12	198B109   129	2748001034	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.23663	-118.58406	T24 ONLY PLAN CHECK FOR TENANT IMPROVEMENT REMODEL OF EXISTING COMMERCIAL LOW RISE.  LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 8,979SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66073	13041-10000-35128	"1807-1831 E 45TH ST BLDG ""C"""	90058	9	112-5A213 137	5106005032	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.00291	-118.24096	T24 PART 6 ENERGY FOR (E) 18,610 SQ FT COMMERCIAL SPACE. RETRO-FITTING 4' FLUORESCENT LIGHT FIXTURES WITH NEW F54T5 LAMPS. SCOPE OF WORK < 400A. PERMIT IS EXISTING. NO NEW/MOVED WIRING, LIGHTING PANEL INSTALLED/RELOCATED PER APPLICANT. SUBJECTED TO FIELD VERIFICATION IF SECTION 131 OF ENERGY CODE NEEDS TO BE COMPLIED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66074	18041-10000-44959	11280 W NATIONAL BLVD	90066	11	120B157   383	4250027017	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.02642	-118.4306	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66075	13041-20001-17783	22470 W DOMINGO ROAD	91364	3	168B101   191	2075038013	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	08/30/2013 12:00:00 AM	ADDRESS	34.15918	-118.61609	((changes to approved set of plans. total # of modules is 23. pc for correction)))PV1 FOR TRANSFORMERLESS INVERTER WITH POWER OPTIMIZER. TOTAL SYSTEM SIZE: 5.83KW. 22 MODULES AND 1 INVERTER. PERMIT INCLUDES SERVICE AND PANEL UPGRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66076	18041-20000-08313	11211 W VENTURA BLVD	91604	2	162B173   255	2366035036	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.14214	-118.37468	TI to (E) commercial retail space.  Building permit issued under 18016-20000-07017.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66077	18041-10000-42413	7817 N VAN NUYS BLVD	91402	6	189B149   533	2210023018	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.21248	-118.44927	REMOVE INDOOR AND OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66078	14041-10001-27606	16800 W ROSCOE BLVD	91406	6	192B133   277	2205002901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM			PC Approved	01/14/2015 12:00:00 AM	ADDRESS	34.2206	-118.49931	INSTALL (1) 250 KW GENERATOR & (1) 225 AMP 480V BOARD.  PLAN CHECK FOR POWER PER INSPECTOR CORRECTION NOTICE. WILL INSTALL THREE 4-POLE AUTOMATIC TRANSFER SWITCHES PER 230.95 GFP REQUIREMENTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66079	13041-10000-01647	19124 W MERION DR	91326	12	213B121   820	2822034005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.27682	-118.55109	PV1 ROOF MOUNTED MICROINVETER SOLAR INSTALLATION ON STANDARD PLAN. SINGLE STORY HOUSE. SYSTEM SIZE IS 3.672 KW [MODULES: REC # REC245PE |||| INVERTERS: ENPHASE  # M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66080	17041-30000-24124	1009 N AVALON BLVD	90744	15	033B205  1105	7420022027	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	ADDRESS	33.78315	-118.26284	Plan check for power and energy. Project site is an existing OSHPD-3 medical office. Project site is in a methane zone. Project scope is a tenant improvement. Total lighting area = 2,922 sq. ft.Note: Building permit has been issued under 16016-40000-31224. Partial electrical permit fees have been paid under 17041-90000-12868.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66081	14041-20000-00989	10235 N BALBOA BLVD	91325	12	204B133   251	2694001035	C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.25666	-118.50254	Change to lighting in the restrooms of an existing retail space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66082	14041-20001-06764	4521 N SHERMAN OAKS AVE 2ND FL	91403	5	168B145  1045	2283017030	CR-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	34.15295	-118.46946	Modification to approved set.  Change of MC cable type to include two insulated copper equipment grounds.  (((PLAN CHECK FOR ENERGY AND POWER. NEW DENTAL OFFICE. UPGRADING TO 600A SERVICE. 2-STORY OFFICE BULDING.BUILDING PERMIT#13041-20000-04707.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66083	13041-20000-04208	10155 N CANOGA AVE	91311	12	204B105   476	2747010022	[T][Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.25509	-118.59748	CONVERT EXISTING 1- STORY MANUFACTURING/ OFFICE BUILDING TO PRECISION MACHINE SHOP WITH ACCESSORY OFFICE AREA.  T.I. EXISTING PORTION.  LOAD IS LESS THAN 400 AMPS, PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66084	19041-20000-26316	11595 W SUNSET BLVD pv1	90049	11	135B145   290	4429026003	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	07/14/2020 12:00:00 AM	ADDRESS	34.06802	-118.47034	pv1install roof mouted pv system sized 2.3KW AC interconnected dwith msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66085	13041-10000-26345	16781 W KNOLLWOOD DR	91344	12	216B137   516	2609007020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	10/24/2013 12:00:00 AM	ADDRESS	34.28482	-118.49635	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A STANDARD PLAN; COMBINER BOX WILL BE USED. SYSTEM SIZE IS7.35KW DC WITH (30) MODULES: TRINA #TSM-245PA05.18(1) INVERTER: FRONIUS #IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66086	17041-10000-35128	3330 W BEVERLY BLVD	90004	13	138A201   136	5501018001	C2-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	11/27/2017 12:00:00 AM	ADDRESS	34.07311	-118.28539	PC for methane detection system with one control panel, 28 detectors and 7 alarms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66087	18041-10000-39413	12332 W OSBORNE PL	91331	7	204B165    26	2537001004	QRD2-1-CUGU, RA-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.25987	-118.40147	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66088	14041-20000-12147	1000 W WILSHIRE BLVD	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	ADDRESS	34.05085	-118.26078	PLAN CHECK FOR T-24 AND EMERGENCY LIGHTING ONLY FOR EXISTING COMMERCIAL HIGH RISE BUILDING 21ST FLOOR SUITE NUMBER 2150 ONLY.  REPLACNING FIXTURES ONLY NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66089	11041-20000-07657	888 W 6TH ST	90017	14	130-5A209 179	5144007401	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM			PC Approved	05/17/2011 12:00:00 AM	ADDRESS	34.05062	-118.25846	T.I. to a high rise building.  Install general/emergency lighting for Chase Bank.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66090	18041-10000-02472	7415 N HAYVENHURST PL	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.2052	-118.49233	REMOVE INDOOR-OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.HANGAR B	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66091	12041-10002-21410	10900 W WILSHIRE BLVD #100	90024	5	132B153   421	4324001031	C2-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM			PC Approved	01/28/2013 12:00:00 AM	ADDRESS	34.05848	-118.44419	Revisions to permitted set of plans:Revised locations and circuiting of FC-1,CU-1, AND SPLIT SYSTEM AC UNITS. Added (3) Emon Dmon meters for the above units. Updated equipment schedule and panel schedules.(((((((Revisions to permitted set of plans-all changes are clouded on the plans.Most of the changes are to the Lighting system and includes reuction of the Lighting wattage.TENANT IMPROVEMENT: change an existing bank to a new citi bank; customer requested full plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66092	11041-10000-11990	1360 S WESTWOOD BLVD	90024	5	132B153   766	4325016015	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/10/2011 12:00:00 AM	08/25/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.05594	-118.44192	New fire alarm system for Ross Dress For Less.  This is a single story building.    Fire alarm is also to be installed in the parking garage complex.  Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66093	12041-10000-22178	6605 N FALLBROOK AVE	91307	3	180B097   311	2038040015	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			09/18/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	05/20/2013 12:00:00 AM	ADDRESS	34.18874	-118.62363	TENANT IMPROVEMENT FOR A RETAIL GROCERY STORE IN AN EXISTING BUILDING. NEW DISTRIBUTION BOARDS, PANELS, AND CKTs. EPC IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66094	15041-10000-18155	826 E TRACTION AVE	90013	14	127-5A215  98	5163013005	(T)(Q)CM-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	34.04473	-118.23534	PLANCHECK FOR T24 ENERGY BASE ON 2008 CODE. TENANT IMPROVEMENT. NO CHANGE IN OCCUPANCY, <400 AMPS IN CONNECTED LOAD. 7676 SQFT, EMERGENCY LIGHTING.Reference to lost application #: 14041-20000-08769	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66095	15041-10000-03080	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/02/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.01118	-118.33649	Title 24 plan check only.  Total area = 1,542 sq. ft.T.I. to existing retail space.  New 200 A panel.  Lights and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66096	19041-20000-38747	5203 N LANKERSHIM BLVD	91601	2	171B173   588	2350017058	C4-2D-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	34.16507	-118.37498	PROVIDE NEW 600 AMP SERVICE FOR COMMERCIAL. SCOPE OF WORK INCLUDES (1) 200 AMP PANEL AND EQUIPMENTS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66097	18041-20001-30201	1402 N CAMPUS ROAD	90042	14	156A223   169	5476019016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.12247	-118.21072	12/12/19CHANGES TO APPROVED SET DELTA 1 CHANGES TO ELEVATION OF SWITCHBOARD.<<<Power and lighting for addition and change of use from (E) duplex to hydroponic agricultural enterprise.  New 600A 240/120V 1ph-3w service.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66098	15041-20001-17399	6600 N TOPANGA CANYON BLVD 1058D	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	07/10/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 3. Changes include fixture manufacturer and Title 24 calculations. *****Previous Work Description*****Plan check for Title 24 only. Project site is an existing tenant space withing the mall. Project scope is a tenant improvement. Total lighting area = 1,374 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66099	17041-20000-23944	10866 W WILSHIRE BLVD ste 560	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM			PC Info Complete	07/17/2017 12:00:00 AM	ADDRESS	34.05907	-118.442	ti to an existing high rise building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66100	16041-10000-22849	600 W WILSHIRE BLVD	90017	14	129A209   100	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.04796	-118.25622	PC FOR LANDLORD SCOPE OF WORK TO PROVIDE POWER FOR FUTURE TENANTS. WORK IS DONE FOR SUITE 100. NEW TRANSFORMER AND 1000A DISTRIBUTION. PC FOR POWER ONLY. NO TI PART OF THIS PERMIT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66101	15041-20001-02762	12484 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66102	11041-10001-18357	6750 W SANTA MONICA BLVD	90038	4	144B185   764	5532027016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.09057	-118.33767	ADDITION OF SECOND LEVEL OFFICE AND EXTERIOR DECK. REPLACE EXISTING WINDOWS/DOORS.(((((((((( CHANGES MADE TO PREVIOUSLY APPROVED SET ADDITION OF NEW CKTS AND NEW PANEL AND TITLE 24.))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66103	17041-10000-44921	11150 W SANTA MONICA BLVD 16TH FL	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.04704	-118.44563	ALTERATIONS IN ELEV LOBBY AND RESTROOMS  OF OFFICES PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66104	13041-10000-03614	948 N BEAUDRY AVE 1-8	90012	1	136-5A213  68	5406026004	R3-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			02/12/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.06846	-118.24604	NEW 8 UNIT APARTMENT BUILDING. NEW LOAD NOT TO EXCEED 400A. PC FOR T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66105	19041-10000-24559	100 S GRAND AVE Tower #1-Hotel	90012	14	132A211    94	5149021***	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	34.05536	-118.24876	Full plan check for a brand new high rise 24-floor 308-unit  guestroom Hotel building (Tower #1) sharing a common parking at lower floor/underground with two other buildings (a 6th floor common podium and a 42-floor 436- residential unit  buidling (Tower # 2)). Scope of tower # 1 includes a medium voltage 5kv 1200A service suppling tower #1 and tower #2. Note Tower# 2 and Podium building will be under a seperated applications.  Most of  title-24 energy calculation is under the application of podium building. All 3 application is under 1 set of plan.Related building application including: 17010-10000-01468                                                                       17010-10008-01468  (((PROPOSED MIXED USE HIGHRISE BUILDING CONSISTING OF 2 TOWERS OVER PARKING. 20 STORY HOTEL AND A 39 STORY APARTMENT BUILDING WHICH INCLUDES  **** AFFORDABLE UNITS. THE COMMERCIAL SPACES WILL BE APPROVED AS A CORE AND SHELL, THE HOTEL ROOMS WILL BE REVIEWED AND APPROVED UNDER THE 10008 PERMIT. THE TENANT IMPROVEMENTS TO BE APPROVED UNDER SEPARATE PLAN CHECK/PERMIT.STEEL STAIRS AND RAILS, CURTAIN WALLS- ALL DOORS AND WINDOWS/STORE FRONTS, GLASS COVERED STRUCTURES ARE DEFERRED STRUCTURALLYVERIFY THAT THE SUSMP CLEARANCE OBTAINED)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66106	16041-10000-21066	7250 N JUMILLA AVE	91306	3	186B117   906	2115019030	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.20259	-118.56325	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.7KWac.(26)MODULES-SUNPOWER SPR-327NE(1)INVERTER-SMA SB7700TL-US-22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66107	15041-20000-38783	4614 N WESTCHESTER DR	91364	3	168A111   107	2174012022	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.1536	-118.58228	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE : 21.582 KW DC.NOTE: PERMIT FEES ARE 0$ DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66108	14041-20001-17570	19411 W LONDELIUS ST	91324	12	195B117   105	2783025053	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	08/18/2014 12:00:00 AM	ADDRESS	34.22997	-118.55629	((CHANGES TO APPROVED SET OF PLANS. CHANGE IN 6 FIXTURES, RECHECK T24)))TENANT IMPROVEMENT TO (E) OFFICE/ WAREHOUSE. PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66109	17041-10001-19786	520 S LA FAYETTE PARK PL	90057	1	135A201   136	5155019007	CR-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.06376	-118.28241	12-21-2017 Changes to an apparoved set of plan. Changes include remove 400A Circuit Breaker and install fuse disconnect and use load side tab to the 2000A Bus(Main disconnect Doesn't have Ground Fault Protection). Changes has been cloudedPlan Check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66110	13041-10000-12876	621 S WESTERN AVE # 302	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	08/28/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	FIRST TIME TENANT IN COMMERCIAL SPACE-GANG JUNG RESTAURANT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66111	17041-10001-12604	833 N BROADWAY	90012	1	135A215   275	5408032011	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	PIN	34.06340622	-118.23820573	PC FOR FIRST TIME TENANT POWER AND ENERFY,  FOR A RESTAURANT/FOOD SERVICE. SERVICE SIZE OF 200A 120/240 1PHASE. SCOPE INCLUDES NEW LIGHTS RECEPTACLES AND EQUIPMENT.PARTIAL SCOPE (20 CIRCUITS) WERE PULLED UNDER MASTER. BLDG # 17016-10000-03510	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66112	17041-10000-15608	4634 N DENNY AVE	91602	4	168B177   821	2421021013	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM			Corrections Issued	05/10/2017 12:00:00 AM	ADDRESS	34.15495	-118.36466	Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 3.8 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66113	19041-20000-44140	240 N BENTLEY CIR	90049	5	138B149    93	4366002021	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.07621	-118.45672	PV1. INSTALL 13.2 KW DC PV SYSTEM WITH (33) MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66114	19041-10000-28600	817 N YALE ST	90012	1	135A215   252	5407021902	OS-1XL	Central	Central City North	Historic Cultural North		2071.03	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.06375	-118.24074	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66115	14041-10001-05603	5311 S CRENSHAW BLVD #A-#B	90043	8	108B185   116	5013018006	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM			PC Info Complete	07/05/2016 12:00:00 AM	ADDRESS	33.99449	-118.33114	PC FOR CHANGES TO APPROVED SET OF PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66116	14041-10000-11051	8 S CHESTER PL	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM			Reviewed by Supervisor	06/03/2014 12:00:00 AM	ADDRESS	34.03102	-118.27718	REMOVE EXISTING SWITCHBOARD INSIDE AND REOLACE WITH SIMILAR SWITCHBOARD OUTSIDE; NEW 600A DISTRIBUTION BOARD AND RECONNECT EXISTING LOADS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66117	19041-10003-03855	920 W BLOOM WALK	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	11/12/2020 12:00:00 AM	ADDRESS	34.01996	-118.28938	Change to an approved set by adding lighting, power and relocating ckts on the plan. New panels also added. Load calculation being updated.. All changes under delta-3 and 4 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66118	15041-10000-31905	3755 S SAWTELLE BLVD BLDG B	90066	11	114B157   145	4234003033	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.01202	-118.42043	T-24 TO AN (E) OFFICE BUILDING. NEW STORAGE SPACE ADDED TO AN OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 112	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66119	17041-10002-34758	1910 E OLYMPIC BLVD	90021	14	121-5A215 121	5166025005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM			PC Approved	07/18/2019 12:00:00 AM	ADDRESS	34.027	-118.2375	DELTA 3 REVISIONS- CHANGE LIGHTING SYSTEM AND REVISED RATING OF ELEVATOR CONTROL(((((((PC for power and energy for new three story warehouse building. PC for new 240/120V 800A service. Installing new switchboard, panels, circuits, equipment, lights, elevator. Total area Indoor+Outdoor=115686sqft.B#17010-10000-01373.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66120	16041-10001-44781	1625-1627 W 25TH ST	90732	15	009B189    86	7563016016	[Q]C2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	33.72342	-118.31398	TI FOR RESTAURANT. PC FOR LIGHTING UPGRADES. ALSO PERMIT INCLUDES CHANGE OF ADDRESS TO MATCH BUILDING PERMIT PLANS. THIS IS T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66121	14041-10000-10424	445 S FERRY ST	90731	15	018B205    15	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	33.74512	-118.26099	This is a combination work at port of la for a reclamation plant. rplacing pumps, vfd s, ckts and soft starters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66122	14041-10000-10927	966 S WESTERN AVE	90006	10	129B193    56	5080008029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.05374	-118.30883	plan check for power and energy. medical office (#106). not oshpd. BLDG#14016-10-07218. CHANGE OF USE to MEDICAL OFFICE (~ 2100 S.F) ON THE FIRST LEVEL OF EXISTING 2-STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66123	16041-10000-32743	12838 W SATICOY ST	91605	2	186B161   482	2324001008	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.20615	-118.41279	T-24, PC FOR ENERGY ONLY. TI FOR A NEW MANUFACTURING BUILDING. SCOPE INCLUDEW NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10684 SQ. FT. B#16016-10000-04140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66124	17041-10001-20564	6064 W HOLLYWOOD BLVD	90028	13	148-5A189 153	5545006030	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	ADDRESS	34.10148	-118.32211	Supplemental PC for power and energy for Music School TI.This permit covers new 800A service, panels F and C, receptacles, lights and equipment. Service is also feeding adjacent building covered under (17041-10001-20496). B#17016-40000-11253. T24 fees covered under master permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66125	17041-10001-15976	20050 W VANOWEN ST D	91306	3	180B113    57	2134013018	[Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.19354	-118.57037	PC for T24 only for new lighting. Installing new lighting nad receptacles with existing panel and branch circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66126	18041-10000-27774	2917 W TEMPLE ST UNIT 2	90026	13	139-5A203 445	5156014010	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village	YES	1958.02	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.07449	-118.27896	PC FOR T-24 ENERGY ONLY FOR OFFICE SPACE IN THE BACK OF THE HOUSE (UNIT 2).THIS IS A TI IN PREPERATION FOR A NEW TENANT. SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1376 SQ.FT. NO BUILDING PERMIT AT THIS TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66127	15041-20001-42579	5753 N CRANER AVE	91601	2	174B173   387	2415004017	R1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM			PC Approved	02/18/2016 12:00:00 AM	ADDRESS	34.17538	-118.36935	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter, (42) modules, and (1) combiner box. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66128	16041-10000-30633	914 E 41ST ST	90011	9	115-5A209 372	5115024016	RD2-1	South Los Angeles	Southeast Los Angeles			2283.20	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.00905	-118.25965	ROOF MOUNTED PV PV1 SFD TOTAL SYSTEM SIZE 3KW AC USING 9 MODULES IN TOTAL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66129	16041-10000-15789	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Issued	08/01/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	T-24, PC FOR ENERGY ONLY. TI TO (2) EXISTING PARKING GARAGE BLD-1 AND BLD-2  UNDER (1) ADDRESS. SCOPE INCLUDES MODIFICATION IN PLACE BY  REPLACING FLOURESCENT LIGHTS WITH LED LIGHTS   BUILT-IN CONTROLS. ALL CIRCUITS ARE EXISTING AND TOTAL AFFECTED AREA IS 571,678 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66130	15041-20000-17742	12418 N GLADSTONE AVE	91342	7	219B161   241	2525019066	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	PIN	34.29583071	-118.4110579	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of service equipment and associated eletrical loads. (Phase 2 of project)Note: Phase 3 of project is under application number 15041-20000-19060	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66131	14041-10001-17370	3245 S LA CIENEGA BLVD	90016	10	123B173  1679	4205035002	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.02879	-118.37386	Revision to approved set per field inspection. Removed 1 meter with Panel HP2, LP2, and T2 (xfrmr), relocating some branch circuits. Changes under Delta-1. Permit under Master E#.<<Plan check for power and lighting.  Total area = 15,351 sq. ft. conditioned; 9,860 sq. ft. outdoor.Core and shell.  Installatino of new pannels, transformers, and lighting.>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66132	16041-10000-02855	1429 N TAMARIND AVE	90028	13	147A191   129	5545014013	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.09648	-118.3192	New fire alarm system to a single story building for daycare use. Instaling (1) FA panel, (2) Communication panels, (19) FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66133	11041-10000-15391	643 N LA CIENEGA BLVD	90069	5	141B173   532	4337003052	C4-1VL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM	09/15/2011 12:00:00 AM		Permit Finaled	10/25/2011 12:00:00 AM	ADDRESS	34.08325	-118.37674	TI FOR AN EXISTING NIGHTCLUB.  PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66134	17041-10000-18148	22930 S LOCKNESS AVE	90501	15	045B193   496	7347017028	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Closed	02/16/2022 12:00:00 AM	ADDRESS	33.81656	-118.30418	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66135	13041-10001-35352	2485 S ARMACOST AVE	90064	11	120B149   165	4257002011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.02776	-118.44796	Expedited RSES plan check per applicant request.{{PV1, Install 4 kW DC roof-mounted solar array, interconnect with main service panel for a one story house. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66136	13041-10000-03302	25950 S BELLE PORTE AVE	90710	15	033B193   274	7411002027	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.05, 2944.20	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	07/17/2013 12:00:00 AM	ADDRESS	33.78686	-118.30101	Upgrade service to 800A. Commercial area with offices. Panel upgrade but not adding any load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66137	19041-10001-14868	20932 W DEVONSHIRE ST	91311	12	204B109   175	2747001048	C4-1, P-1, RE11-1	North Valley	Chatsworth - Porter Ranch, Northridge	Chatsworth, Northridge South		1133.21, 1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2019 12:00:00 AM			Corrections Issued	05/10/2019 12:00:00 AM	ADDRESS	34.25702	-118.58975	PC FOR A NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. SCOPE INCLUDES ADDING 7.44KWdc / 5.0KWac OF PV TO AN EXISTING PV SYSTEM. TOTAL SYSTEM SIZE WITH NEW AND EXISTING PV SYSTEMS IS 8.94KWdc / 8.00KWac. SCOPE INCLUDES ADDING:(24)MODULES-HANWHA Q.PEAK DUO BLK-G5 310(24)SOLAREDGE OPTIMIZERS-P320(1)INVERTER-SOLAREDGE SE5000H-US(1)COMBINER PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66138	15041-20001-16882	6555 W BARTON AVE 2nd Floor	90038	4	144B185   969	5532014038	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM			PC Approved	10/05/2015 12:00:00 AM	ADDRESS	34.08785	-118.33475	Changes to an approved set of plans. Changing emergency lighting, taking some lights off emergency circuit.(((PC FOR POWER AND ENERGY. TI NO CHANGE OF USE,OFFICE. TOTAL AREA 32334 SAQ FT. (PHASE 1 ENTIRE FLOOR))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66139	19041-10000-27240	7463 S MIDFIELD AVE	90045	11	099B173   172	4127009017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	33.96959	-118.37569	[EPLAN1]PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 20 MODULES USING P400 OPTIMIZERS AND 1 ESS(TESLA POWERWALL) CONNECTED TO EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66140	19041-10000-24790	51 WORLD WAY TPSS-1	90045	11	090B165    25	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Issued	08/16/2019 12:00:00 AM	ADDRESS	33.94512	-118.39916	TRACTION POWER SUBSTATION #1 AT LAX. (AUTOMATED PEOPLE MOVER AT LAX)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66141	15041-20000-41988	8229 W FOOTHILL BLVD	91040	7	210B181   148	2550022004	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			12/14/2015 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	01/29/2016 12:00:00 AM	ADDRESS	34.25984	-118.31235	Tenant Improvement of Change of use from Retail to office. PC for Energy only, total area: 2,046 sq.ft.PC by EG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66142	15041-10001-37839	454 E COMMERCIAL ST parking	90012	14	130-5A215  43	5173001904	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05313	-118.23621	PC only due to lost approved set.This is 6 out of total of 6 plans under same project.DOT project (same lot different addresses)***********************************************************************************new two-stories parking structuresee 15010-10000-01114	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66143	18041-20000-37125	1050 S FREDERICK ST	90291	11	111B145  1707	4243003053	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	33.99927	-118.46029	ti to an existing commercial building.  adding new lighting new controls to new panel.  newly connected load < 400 amps plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66144	17041-10000-34745	2817-2819 W JAMES M. WOOD BLVD	90006	1	132B197   738	5077024029	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.05602	-118.28974	PC for restuarant TI. Installing new circuits, equipment and lighting. Total area of 1333sqft.B# 17016-10000-08924	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66145	17041-20000-15563	309 S BUNDY DR	90049	11	132B141   521	4404011011	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Expired	08/28/2023 12:00:00 AM	ADDRESS	34.05753	-118.47648	pv1install roof mounted pv system sized 3.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66146	12041-10000-18596	13972 W AUBREY ROAD	91423	4	162B153   529	2272032042	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2012 12:00:00 AM			Reviewed by Supervisor	09/19/2012 12:00:00 AM	PIN	34.1387116	-118.4358451	Plan check for new ground mounted 29.4W DC photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66147	13041-10000-32823	1160 W HARRY BRIDGES BLVD	90744	15	027B201   208	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	PIN	33.77018478	-118.27675111	PLAN CHECK FIRE ALARM SYSTEM FOR NEW 1-STORY DRIVER SERVICE BUILDING FOR THE PORT OF LA (PART OF TRAPAC TERMINAL PROJECT). 1 PANEL AND 15 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66148	14041-20000-03496	3928 N ENCINO HILLS PL	91436	5	162B133   125	2287015051	RE11-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.14163	-118.49982	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8.2KW AC USING ENPHASE M215 MICROINVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66149	19041-10000-23376	445 S FIGUEROA ST	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	10/02/2020 12:00:00 AM		Permit Finaled	09/13/2021 12:00:00 AM	ADDRESS	34.05295	-118.25675	P.C TITLE 24 FOR OUTDOOR LIGHTING COMMERICAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66150	11041-10000-22460	825 E 4TH ST 1-53	90013	9	127-5A215 174	5163011028	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Apartment			10/20/2011 12:00:00 AM	10/27/2011 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.0435	-118.23728	Fire alarm for 6-story apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66151	16041-30000-18519	8638 N OSO AVE	91306	3	195B113   638	2781014003	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.22763	-118.57528	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66152	17041-10000-07269	1116 W D ST BLDG 11-LOT 8	90744	15	027B201    23	7417010900	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM				INSTALLATION OF A NEW FA SYSTEM FOR A 3-FLOOR APARTMENT BUILDING. 2 FA PANELS AND 43 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66153	16041-10000-04952	6611 S 6TH AVE	90043	8	102B189    64	4008008028	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.97967	-118.32374	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (21)MODULES-SUNEDISON SE-F270KZD-3Y(21)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE-6000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66154	18041-10000-47207	8000 W SUNSET BLVD	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.09783	-118.36466	Full plan check per applicant request. Scope include new lighting and equipment for a retial store with a total area of 13,899-SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66155	14041-20001-12934	4919 E CORINGA DR	90042	14	157-5A225  95	5476008042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.12655	-118.20694	EXPEDITE PER CUSTOMER REQUEST.PV1 ROOF MOUNTED PV SYSTEM SIZED 8.25KW INTERCONNECTED WITH MAIN PANEL.MAIN PANEL UPGRADED TO 200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66156	16041-10000-00031	2511 W 3RD ST	90057	13	135A203    96	5155033018	C2-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.02	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	34.06525	-118.27685	New Methane Detection system, (3) horn strobes (3) smoke detectors in a low rise Dialysis Clinic.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66157	19041-20000-53601	7961 N BRIMFIELD AVE	91402	6	189B149   335	2209015040	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	09/18/2021 12:00:00 AM	ADDRESS	34.21593	-118.45769	Plan check for PV roof mounted system, PV system size: 7.6KW AC, 10.335KW DC with 39 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66158	12041-10000-17333	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	33.78054	-118.23195	Addition motor loads to a classified/hazardous area in a refinery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66159	17041-10001-41641	2301 N HOBART BLVD	90027	4	153B193   211	5588001023	RE11-1	Central	Hollywood	Hollywood United, Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.1137	-118.30542	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66160	14041-10000-31107	8163 N LANKERSHIM BLVD	91605	6	192B169   634	2310007024	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.21916	-118.38802	Energy plan check for a commerical builing; replacing lighting fixture at the same loaction.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66161	12041-10000-30748	4137 W GARDEN AVE	90039	13	157-5A205  71	5594024030	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.12701	-118.26926	PV1 Plan check roof mounted 2.45KW photovoltaic system using Enphase M215 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66162	14041-20000-02002	625 W ROMULO ST	90065	1	144A219   181	5453017023	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.08941	-118.22163	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66163	18041-10001-14610	3260 S CLUB DR	90064	5	123B165   698	4316030025	R1V2	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.0328	-118.40233	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66164	14041-20000-01367	15303 W VENTURA BLVD SUITE 1510	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.15413	-118.46661	PC FOR T24 ENERGY ONLY. OFFICE REMODEL. WORK DONE IN SUITE 1510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66165	12041-10000-19930	10009 N FULLBRIGHT AVE	91311	12	204B109   470	2741021020	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	11/26/2012 12:00:00 AM	ADDRESS	34.252	-118.57808	This is a SFD, one story, solar edge inverter with optimizer. (PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66166	18041-10000-11036	11740 W SAN VICENTE BLVD #203	90049	11	129B145    75	4265006074	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.05308	-118.4669	"PC for T24 only for Yoga studio TI withing existing commercial space. Installing two panels, lights, receptacles and equipment. Total area is 2117sqft. B#18016-10000-09187.TI FOR NEW YOGA STUDIO,""CORE POWER YOGA"" WITHIN EXISTING COMMERCIAL TENANT SPACE; WORK INCLUDES NON STRUCTURAL PARTITIONS, DOORS, FIXTURES, AND FINISHES"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66167	18041-20000-48782	3984 N TARRYBRAE TER	91356	3	162B117   115	2180004017	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.14229	-118.56067	Plan check for PV roof mounted system installed into an existing system. Addition system size: 3.8kW with 13 PV Modules and 1 LG Chem RESU 10H 9.8kWh. New Total PV System size: 14.19kW DC, 12.6kW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66168	19041-20001-12104	551 N LILLIAN WAY	90004	4	141B185   995	5523008009	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM			PC Approved	05/06/2019 12:00:00 AM	ADDRESS	34.08036	-118.32851	06-06-2019 Changes to an approve set of plans, changes include remove perforance meter. Changes has been clouded.  Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66169	13041-10000-32805	682 W HARRY BRIDGES BLVD YARD OPS	90744	15	027B201   336	7440015***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Issued	11/22/2013 12:00:00 AM	ADDRESS	33.77	-118.26886	Fire alarm for NEW 1-STORY YARD OPERATIONS BUILDING FOR THE PORT OF LA.  (PART OF TRAPAC TERMINAL PROJECT).  15 DEVICES AND 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66170	17041-10000-23340	11401 N PORTER RANCH DR BLDG 3	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	03/05/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 3 of 10.  Type I.       Building permit #17010-10000-02379	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66171	10041-20000-20948	11075 W SANTA MONICA BLVD #100-#175	90025	5	129B153   757	4324033022	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM			PC Info Complete	10/21/2010 12:00:00 AM	ADDRESS	34.04799	-118.44397	T.I. to existing low rise building in 1st floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66172	13041-10002-05744	380 WORLD WAY #T73-T74	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	10/02/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	ORIGINAL WAS LOST . THIS PLAN CHECK ONLY TO RE-STAMP A COPY OF THE APPROVED PLAN.  NO CHANGE FROM PREVIOUS PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66173	18041-10000-11891	6515 N TOPANGA CANYON BLVD	91303	3	180B101   601	2139002030	(WC)TOPANGA-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.18856	-118.60614	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66174	15041-10000-37156	1017 N MANZANITA ST	90029	13	145-5A201 477	5427002006	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM			PC Info Complete	11/04/2015 12:00:00 AM	ADDRESS	34.09114	-118.28251	VOID......PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(8) KYOCERA MODULES 265WATTS(1) PVI 3.0KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66175	18041-10000-16915	20452 W VIA CELLINI	91326	12	219B109   260	2701055010	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Issued	05/08/2018 12:00:00 AM	ADDRESS	34.29472	-118.581	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (30) MODULES AND (30) OPTIMIZERS, AND (1) INVERTER. TOTAL SYSTEM SIZE 10.5KWDC AND 10KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66176	18041-10000-09301	8428 W MELROSE PL	90069	5	141B173   505	5528017034	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/14/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.08342	-118.37435	PC FOR POWER ONLY. INSTALLATION OF A NEW 800A 120/240V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD. REFEEDING EXISTING PANELS TO NEW SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66177	18041-10000-18806	6600 N TOPANGA CANYON BLVD # 99C	91303	3	180B101   822	2139004019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR T24 ONLY, TI IN AN EXISTING RETAIL SPACE #99C. SCOPE INCLUDES NEW CIRCUITS. LIGHTS AND RECEPTACLES.  TOTAL AREA: 1278 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66178	17041-10000-20143	5200 N LANKERSHIM BLVD #820	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	PC FOR TI OF OFFICES IN A COMM. BUILDING (HIGH RISE) FOR TITLE -24  ENERGY ONLY. SCOPE INCLUDE NEW LIGHTS AND RECEPTACLES AND NEW CIRCUITS. TOTAL AFFECTED AREA 4443 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66179	18041-20002-20095	8811 W BURTON WAY	90048	5	138B169   687	4334011063	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			PC Approved	10/31/2019 12:00:00 AM	ADDRESS	34.07249	-118.38417	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET CLOUDED CHANGES ONLY. CHANGE TO INTERIOR LIGHTING AND REMOVAL OF SOME OF EXTERIOR LIGHTING. CHANGE TO EM EGRES PHOTOMETRICS, LIGHT FIXTURE SCHEDULE, PANEL SCHEDULE LOADS, AND T24 INDOOR/OUTDOOR SHEETS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66180	19041-20000-23255	4531 W HOLLYWOOD BLVD	90027	4	147B197   567	5542003013	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	02/01/2023 12:00:00 AM	ADDRESS	34.099	-118.28806	new fire alarm system 592 devices and facp.  plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66181	18041-10000-32785	2101 W COLORADO BLVD	90041	14	162A223    91	5671010029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.13937	-118.21209	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66182	14041-20000-18621	19626 W NORDHOFF ST	91324	12	198B117   223	2783028004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/10/2014 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.23527	-118.56116	Remodel of (E) commercial restaurant space (single-story building).  Plan check for power and energy.  Proposed occupant load of 308.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66183	16041-10001-31249	8363 N RESEDA BLVD #14	91324	12	192B125   489	2785018004	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.22256	-118.53629	TI PC AND PERMIT FOR MASSAGE PARLOR TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66184	17041-10000-35328	3035 N NORTH COOLIDGE AVE	90039	13	150B213   768	5442023006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.10497	-118.24426	INTERIOR ALTERATIONS for manufacturing buildingPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66185	17041-20001-40209	13449 W INWOOD DR	91423	4	162B157   574	2373027025	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2017 12:00:00 AM			PC Approved	12/14/2017 12:00:00 AM	ADDRESS	34.14052	-118.42589	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.10.4kW ungrounded system. Derating main to 175A. (2) 5.2kW inverters.(37) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66186	16041-20000-25132	1966 N CARLA RDG	90046	4	153B169   984	5564018035	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM			PC Approved	10/25/2016 12:00:00 AM	ADDRESS	34.11192	-118.39101	NEW 800 AMP SERVICE FOR SFD.  PLAN CHECK FOR POWER ONLY.  PERMIT FEES PAID UNDER BUILDING APPLICATION NUMBER 15010-30000-03438New two story single family dwelling with attached garage over basement with roof deck	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66187	16041-10001-20219	10979 W BLUFFSIDE DR	91604	2	162B173   217	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.14174	-118.36926	this is plan check only. master application permit feePC FOR SEWER EJECTION PUMPS. LOCATED IN PIT DEEMED HAZARDOUS LOCATION. PC FOR POWER ONLY. NO T24 ON PLANS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66188	16041-20000-25374	12555 W VANOWEN ST	91605	2	183B161   924	2324029011	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	05/06/2020 12:00:00 AM	ADDRESS	34.19409	-118.40698	Plan check for new 13 units apartment building 3story. Total area: 10,057 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66189	14041-10000-18157	250 W 5TH ST	90731	15	018B201   823	7455019032	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	33.74004	-118.28238	PLANCHECK FOR T24 ENERGY. CONVERT PORTION OF PARKING GARAGE INTO WEIGHT ROOM FOR ACCESSORY USE TO EXISITNG SCHOOL.   1302 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66190	15041-20000-12288	6250 N TOPANGA CANYON BLVD # 1587	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for 1st time tenant for Go Greek Yogurt & Westfield. Total area: 971 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66191	16041-10001-42763	14624 W HART ST	91405	6	183B149   415	2219024021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.19744	-118.45175	EXPEDITE PER APPLICANT REQUEST.((((((PV1. AN ADDITION TO AN EXISTING PV SYSTEM. ADDING 4.0KWac TO THE EXISTING SYSTEM.(16)MODULES-SOLARWORLD SW290(16)MICROINVERTERS-M250-60-2LL-S25	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66192	10041-10000-20370	5150 W WILSHIRE BLVD 2nd, 3rd &-4th Flrs	90036	4	132B181    35	5507025021	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/18/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	05/06/2011 12:00:00 AM	ADDRESS	34.06202	-118.3421	TI IN AN EXISTING OFFICE BUILDING ON THE 2ND, 3RD & 4TH FLOORS.          PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66193	17041-10000-28442	725 S FIGUEROA ST #3200	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only in existing space T.I. office sapce. Total area: 6,375 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66194	18041-20000-15047	11202 S WILLOWBROOK AVE	90059	15	087A215    89	6069025001	M2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Closed	07/27/2018 12:00:00 AM	ADDRESS	33.93337	-118.24003	PV1.  Install 5.1 kW DC/4.59 kW AC CEC roof mounted grid tied PV system.  (17) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66195	19041-10000-09395	5900 W WILSHIRE BLVD	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.06237	-118.35809	"TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING ON LEVELS 1, 14, 15, 16 & 18 OCCUPIED BY ONE TENANT (LACMA). TOTAL ADDED LOAD > 400AMP, TOTAL AREA: 34,000 SQR FT. PLAN CHECK FOR POWER & ENERGY. (MODIFICATION  TO SEP ""FA"" IS REQUIRED) BULDING PERMIT: 19016-10000-06258"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66196	14041-20000-06411	7463 N VARNA AVE	91605	2	186B157   249	2328027020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	02/23/2015 12:00:00 AM	ADDRESS	34.20651	-118.42487	pc for power. new 600a rated equipment. existing 600A pull section, new 600A service board with 3 new meters. aic to match existing pullbox, 15K minimum	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66197	16041-10000-44765	1741 N CHEROKEE AVE	90028	13	148-5A185  32	5547009014	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.10281	-118.33488	Plan check for PV roof mounted system on commercial building. System size: 12.0kW with 55 modules JAP6-72-315 and 1 inverter(12.0kW) FRONIUS USA connected to MSP 400A switch board.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66198	12041-10001-03498	11262 W VENTURA BLVD	91604	2	162B173   435	2378010008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			07/10/2012 12:00:00 AM			PC Approved	07/10/2012 12:00:00 AM	ADDRESS	34.14102	-118.37532	Modification to label fixtures on previously approved set of plans.               <<<<Plan check T24 Energy/Emergency lighting for restaurant TI. Permit for new 400A service, switchboard, panel, and branch circuits.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66199	19041-20001-49576	14224 W NORDHOFF ST	91402	6	195B153    11	2639026009	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM			PC Approved	06/04/2021 12:00:00 AM	ADDRESS	34.23517	-118.44278	PV3 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 28.38 KW DC/25.693 KW AC CEC. SCOPE OF WORK CONSISTS OF (86) PV MODULES WITH OPTIMIZERS, A 9 KW INVERTER, A14.4 KW INVERTER, AND A SUB PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66200	17041-20000-43034	116 E WASHINGTON BLVD	90292	11	105A147   211	4225002015	C4-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM			PC Approved	11/30/2017 12:00:00 AM	ADDRESS	33.97996	-118.4649	ti to an existing commercial building.  adding new lighting new controls to new panel. newly connected load < 400 amps.  plan check for indoor energy only.  permit fees paid under application number 17041-20000-32693this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66201	13041-10000-13086	9650 N COLUMBUS AVE	91343	7	201B145   504	2656009025	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2013 12:00:00 AM	05/20/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.24603	-118.46517	PV1 8.085kw XFMR INV. 1 STORY HOUSE. STD. ROOFMOUNT.  [ (1x) INV: sunnyBoy 7000-US ][ (33x) MOD: TSM-245 PC/PA05 ]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66202	19041-20000-50881	3308 S MENTONE AVE	90034	5	120B161   102	4314022036	R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	08/08/2023 12:00:00 AM	ADDRESS	34.02849	-118.4115	PLAN CHECK FOR NEW FIRE ALARM SYSTEM. 1 FIRE ALARM PANEL AND 88 FIRE ALARM DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66203	13041-10000-04733	1800 S ROBERTSON BLVD	90035	10	129B169  1331	4303006001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2170.00, 2696.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.04653	-118.38597	First time tenant in a small retail space (~1000 sq ft).  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66204	10041-10000-05840	916 1/2 N LA CIENEGA BLVD	90069	5	144B173   330	5529006049	C4-1VL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	03/31/2010 12:00:00 AM		Permit Expired	09/03/2012 12:00:00 AM	ADDRESS	34.08752	-118.37624	Plan check T-24 energy (general/emergency lighting) for a TI of an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66205	14041-20000-03431	16442 W GUNTHER ST	91344	12	213B137   120	2610020025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.28347	-118.49027	Roof mounted PV system with 6KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66206	16041-10000-27954	19681 S PACIFIC GATEWAY DR	90502	15	057B197    35	7351034056	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.85319	-118.29547	PC FOR POWER. ENERGY STORAGE SYSTEM , (E)MAIN SERVICE 4000A, INSTALLING  FOUR 18KW BATTERY-INVERTERS AND TWO 100KW BATTERY-INVERTERS TO SAVE  AND USE ENERGY  DURING PEAK TIME HOURS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66207	14041-10000-12192	3215-3223 W BEVERLY BLVD	90026	13	138A201   167	5156005012	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	PIN	34.07271258	-118.28353393	plan check for power. plan check request per applicant. installation of 600A equipment. cell site located outdoors. 2 story buildingBLDG#13016-10-17060:INSTALL  (12) PANEL ANTENNAS AND (24) REMOTE RADIO UNITS ON ROOF BEHIND NEW SCREENING ; INSTALL NEW EQUIPMENT CABINETS ON NEW STEEL PLATFORM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66208	15041-20000-29406	3709 N LONGVIEW VALLEY ROAD	91423	4	162B149   450	2274006003	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	01/13/2016 12:00:00 AM	ADDRESS	34.13854	-118.44998	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66209	10041-10000-03917	501 S SPRING ST	90013	14	129A211   112	5149034006	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.04739	-118.24992	ti , existing fire alrm , addition of 17 device and one power supply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66210	18041-20001-24433	10910 N SWEETWATER CT	91311	12	210B117   426	2708030004	(T)(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.26881	-118.56454	9/26/2018chnages to an approved set of plans.  changes to add load center and pv interconnection to msp.((((Plan check for PV roof mounted system, system size: 15.2kW with 44 modules and 2 inverters(7.6kW) connected to existing 400A Service.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66211	19041-10000-14928	800 S VERMONT AVE	90005	10	132B197   469	5077023029	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.05755	-118.29147	Replacing Existing Fluorescent troffers with LED retrofit kits. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66212	12041-10000-12359	16221 W MULHOLLAND DR	90049	5	159B137   413	2293017001	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	08/29/2012 12:00:00 AM	ADDRESS	34.13027	-118.48588	new fire alarm for an existing church, two story with bacony, one panel and 231 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66213	19041-20000-04433	254 S WESTGATE AVE	90049	11	132B145  1312	4401004020	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.05863	-118.47125	Plan check for PV roof mounted system, system size: 2.4kW DC, 2.098KW AC with 8 PV Modules and 8 microinverters connected to 600A Service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66214	12041-10001-13787	1660 W VENICE BLVD	90006	1	126B197   184	5056022022	CM-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/09/2012 12:00:00 AM	ADDRESS	34.04407	-118.29097	PLAN CHECK FOR REVISION TO APPROVED T24 ENERGY PLANS. CHANGES TO LIGHTING LAYOUT, ADD FIXTURES, AND REVISE CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66215	15041-10001-29019	910 E 61ST ST	90001	9	105B209   123	6007008003	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	33.98432	-118.25922	01/24/16Changes to an approved set of plans. Changes include feeding existing panels with current limiter fuses.Note: Permit is paid under PCIS#15041-10000-29019	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66216	13041-10000-12023	6925 W HOLLYWOOD BLVD	90028	13	147B181   112	5548004022	C4-2D-SN, R4-2D	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Finaled	09/04/2013 12:00:00 AM	ADDRESS	34.10171	-118.34113	Remodel of the Chinese Theatre.  Install new subpanels and branch circuits.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66217	17041-20000-35822	20406 W VIA MANTUA	91326	12	219B109   318	2701059026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Issued	12/19/2017 12:00:00 AM	ADDRESS	34.29947	-118.57867	(4) 14KW ENERGY STORAGE SYSTEM + PV1 ROOFMOUNTED PV SYSTEM. SYSTEM SIZE: 14.95 KWPERMIT FEE IS 0$ AS DETERMINED BY SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66218	18041-20000-28233	2100 W 3RD ST	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM			Reviewed by Supervisor	08/09/2018 12:00:00 AM	ADDRESS	34.06281	-118.2731	Plan check for power and energy for Medical Clinic Outpatient  T.I. in existing space. Total area: 9457 sq ft. B#18016-20000-23956	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66219	17041-20000-13510	8070 N WEBB AVE	91605	6	189B169    65	2310007006	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	10/27/2022 12:00:00 AM	ADDRESS	34.21774	-118.38933	Plan check for power and energy. Project site is a new office building. Work includes a 600-amp service and a total lighting area of 7,712 sq. ft.Note: Building application has been generated under 17010-20000-00007	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66220	14041-20000-18190	19556 W HAMLIN ST	91335	3	180B117   668	2132012002	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.18878	-118.55987	4.76KW AC PV1 roof-mounted system with (17) Enphase M250 mincroinverters and SolarWorld Plus SW280 Mono modules connceting through an sub panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66221	17041-20000-18649	12500 N MIDDLECOFF PL	91344	12	219B137    31	2605004020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			Verifications in Progress	07/05/2017 12:00:00 AM	ADDRESS	34.29917	-118.49517	pv1install roof mounted pv system sized 10.4kw interconnected with msp. using 37 PV modules with optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66222	12041-10001-16141	14537 W ARCHWOOD ST	91405	6	180B149   115	2236009008	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Approved	12/18/2012 12:00:00 AM	ADDRESS	34.19306	-118.45004	((((((   12-18-12 M.Z  THIS APPLICATION PREVIOUSLY APPROVED FOR CENTRAL STATION  HOWEVER  ELECTRICAL INSPECTOR REQUESTED FULL FIRE ALARM PLAN CHECK. THIS IS APLANCK ONLY.)))))     central station , one panel, 2 devices, two story mixed use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66223	18041-10000-29149	5218 W 104TH ST	90045	11	090B173   320	4129035019	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Issued	08/03/2018 12:00:00 AM	ADDRESS	33.94169	-118.37085	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66224	15041-20001-44062	10421 N KEOKUK AVE	91311	12	207B113   271	2707016004	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	01/12/2016 12:00:00 AM	ADDRESS	34.26026	-118.57429	Expedite per applicant request{{{{{{Plan check for PV roof mounted system. System size: 12.0kWac with  40 modules and 2 inverters (6.0kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66225	18041-10000-24381	3100 N PASADENA AVE	90031	1	141A223   160	5206002001	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1994.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	07/07/2018 12:00:00 AM	ADDRESS	34.08102	-118.2141	INSTALL A NEW 3KW ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY HOME WITH 10 PV MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66226	18041-10003-07709	8913 W 25TH ST	90034	10	126B169  1229	4302015022	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.03864	-118.3858	DELTA 1 CHANGES ONLY.PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING.  CONISIT OF 24 MODULES(Trina Solar 300W) AND A CENTRAL INVERTER (DELTA SOLIVIA 5.2) . SYSTEM SIZE IS 5.2KWac AND 7.2KWdc.SCOPE INCLUDES NEW LOAD CENTER (200A each).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66227	18041-10000-11482	767 S ALAMEDA ST # 198	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Info Complete	06/27/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	INTERIOR TENANT IMPROVEMENT 1ST FLOOR RETAIL STORE  1349 SF.( FIRST TIME TENANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66228	17041-10001-11541	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM			PC Approved	10/03/2018 12:00:00 AM	ADDRESS	34.06664	-118.46903	REVISION TO PERMITTED SET OF PLANSADDED CURRENT LIMITING FUSES TO REDUCE AVAIABLE SHORT CIRCUIT CURRENT AT ELEVATOR DISCONNECT SWITCHES BELOW 5KA. ((((((((((PC FOR POWER AND ENERGY FOR NEW SCHOOL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66229	13041-20000-16444	2749 N NICHOLS CANYON ROAD	90046	4	156B177   777	5570003015	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.11985	-118.35891	PV1 STANDARD PLAN TOTAL SYSTEM SIZE: 11.515KW. 48 MODULES, 1 COMBINER, AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66230	11041-10000-18773	2005 N HIGHLAND AVE	90068	4	150A185   119	5549030013	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM	11/03/2011 12:00:00 AM		Permit Finaled	02/27/2012 12:00:00 AM	ADDRESS	34.10671	-118.33767	Renovation of a 7 story hotel , addition of 10 new panels, 377 new branch ckts, title 24 energy. power and lighting.  <<<<Additional EPC fees & FO fees paid under Submittal 2>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66231	19041-10000-32025	110 E 9TH ST 7TH FLR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Energy plan check for a partial office T.I located on the 7th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 26,231-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66232	18041-20001-01338	555 S FLOWER ST Suite 3450	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.05048	-118.25755	Revisions to approved set.  Changes to lighting fixture schedule and lighting plan layout.  Review of clouded revisions delta-1, 0, and A. (((Plan check for Title 24 only. Project site is a suite on the 34th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,540 sq. ft.Note: Building application has been generated under 18016-10000-00446)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66233	10041-10002-03624	6724 W HOLLYWOOD BLVD	90028	13	148-5A185 146	5547012018	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/26/2011 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.10139	-118.33715	Modifications to previously approved plnas for a T.I. for 8-story high rise building Church of Scientology.  Plan check for power and energy. New electrical system with 1600A service. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66234	17041-20000-09565	7963 N VAN NUYS BLVD Unit B	91402	6	189B149   310	2210019004	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.21603	-118.44897	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE FROM (E) RETAIL TO (N) DENTAL OFFICE (1,215 sqft)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66235	15041-20000-19293	7608 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.20887	-118.46478	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 3.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66236	12041-10000-02354	500 N PIER A ST BERTH 161	90744	15	027B205   619	7440009911		Harbor	PORT OF LOS ANGELES			2949.00	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	06/21/2012 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	33.76414	-118.26561	New CNG- dispenser station AT BERTH 161 IN WILMINGTON- CONSISTS OF TWO COMPRESSORS, ELECTRICAL EQUIPMENT- Class I div2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66237	17041-10001-18900	6848 N FIRMAMENT AVE	91406	6	183B141   677	2234002009	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.1955	-118.47276	EXPEDITE FEE FOR PV*************** PC FOR ROOF MOUNTED PV SYSTEM. SYSTEM SIZE 15.2KWAC INCLUDES 57 MODULES WITH OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66238	15041-10000-21313	11250 W SANTA MONICA BLVD 1-78	90025	11	129B149   438	4261008022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.04661	-118.44736	T-24 TO AN (E) HOTEL BUILDING, HOLIDAY INN. SCOPE OF WORK INCLUDES KITCHEN IN COMMON SPACE. PC FOR ENERGY ONLY. TOTAL SQ. FT. 7885	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66239	16041-10000-02777	2968 W 6TH ST	90005	10	135A201   140	5077007029	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Apartment			01/26/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Closed	08/09/2017 12:00:00 AM	PIN	34.06352386	-118.28606577	PC FOR A NEW FIRE ALARM SYSTEM TO A NEW 7 STORY, 398 UNIT MIXED-USED RESIDENTIAL BUILDING OVER 3 LEVLES OF SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES 1347 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL, AND 1 COMMUNICATION PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66240	18041-10000-29772	10250 W SANTA MONICA BLVD #2720	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for the first time T.I virtual reality entertaininment space ""Dreamscape Immersive"" within Westfield Century City Mall. Scope includes new lighting and equipment with a total area of 7,783-SQ FT. (Tailored Method)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66241	11041-10000-27142	810 S SPRING ST BSMNT	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/20/2011 12:00:00 AM			PC Approved	12/20/2011 12:00:00 AM	ADDRESS	34.04268	-118.25375	remodeling of the interior of existing bar-new luminires and circuitsplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66242	17041-20000-03341	15001 W CORONA DEL MAR	90272	11	123B129   651	4411024006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	ADDRESS	34.03169	-118.52255	PLANCHECK ONLY FOR POWER ONLY. SINGLE FMAILY RESIDENCE. 600AMP SERVICE.  BUILDING PERMIT # 14010-30000-01245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66243	17041-10001-35848	8500 W BEVERLY BLVD 119	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	DELTA 6 REVISIONS TO PERMITTED SET OF PLANS-SLIGHT CHANGES TO THE LIGHTING SYSTEM IN THE LOUNGE AREA; UPDATED COMPLIANCE FORMS; CHANGES ARE CLOUDED AND IDENTIFIED ON THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66244	14041-20000-04772	1020 S FIGUEROA ST	90015	14	127-5A207  71	5138012023	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.04442	-118.26422	ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66245	10041-20000-01073	3057 N SAN FERNANDO ROAD	90065	13	153A213    84	5458009018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.01	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM	01/29/2010 12:00:00 AM		Permit Finaled	02/25/2010 12:00:00 AM	ADDRESS	34.11433	-118.24513	energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66246	19041-10000-11787	8201 N RHODES AVE	91605	2	192B165   721	2308020012	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.21991	-118.4032	NEW 9KW ROOF MOUNTED PV SYSTEM WITH 25 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66247	12041-10001-20461	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			PC Approved	01/17/2013 12:00:00 AM	ADDRESS	34.07594	-118.35916	CHANGES TO APPROVED PLAN UNDER 12041-10000-20461. THE CHANGES UNDER DELTA  6 ONLY, REMOVING THE LOCATION FROM THE ROOF TO ACCESIBLE PLACE ON APPROVED PEDESTAL , REQUESTED BY INSPECTOR.  RATINGS AND MANUFCATURER STILL THE SAME.  THIS IS PLAN CHECK ONLY, PERMIT EXISTS UNDER THE ORIGINAL NUMBER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66248	19041-20000-30960	15233 W VENTURA BLVD STE 1204	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM			PC Info Complete	08/08/2019 12:00:00 AM	ADDRESS	34.1538	-118.46502	T24 PLAN CHECK ENERGY ONLY, LIGHTS AND OUTLETS ONLY. FOR TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING STE 1204. TOTAL SQUARE FOOTAGE = 1418 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66249	13041-10000-34464	6344 N TOPANGA CANYON BLVD	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Closed	08/22/2018 12:00:00 AM	ADDRESS	34.18628	-118.60544	PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL. WESTFIELD MALL. BUILDING A. BUILDING PERMIT # 13010-10000-02904New retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66250	19041-20000-49080	11934 W HOYT ST	91342	7	216B165   111	2531030009	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.2859	-118.39302	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 12.54 KW DC/11.71 KW AC CEC. SCOPE OF WORK CONSISTS OF (38) PV MODULES WITH MICROINVERTERS AND A SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66251	12041-10002-08065	14711 W GLEDHILL ST	91402	7	198B149   107	2650031011	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	12/11/2012 12:00:00 AM	ADDRESS	34.24151	-118.45414	Modification to correctly show feeder routing throug sub panel on house to main panel at garage and upgrade the sub-panel to 200Amp.                   <<<<<New 10.464kw rooftop, photovoltaic system for an existing single family residence.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66252	15041-20000-33841	2800 N GLENDOWER AVE	90027	4	153B197   167	5588011008	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.11561	-118.2965	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20 KW.Note: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66253	14041-20000-03103	12600 W VOSE ST	91605	2	183B161   418	2324023018	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.19827	-118.40747	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66254	17041-20000-41388	1832 S BARRINGTON AVE	90025	11	126B149   960	4262021020	RD1.5-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Apartment			11/15/2017 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.03921	-118.45191	New 11-unit, 3-story apartment building.  800A 120/240V 3ph-4w service.  Plan check for power and energy. Building permit under 17010-20000-01512.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66255	11041-20000-16058	12840 W RIVERSIDE DR #100	91604	2	168B161   459	2357033012	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			08/01/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	PIN	34.15731555	-118.4128018	Plan check power and energy for new dentist office in existing medical office building. Suite #100	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66256	19041-20000-04348	6140 N LAUREL CANYON BLVD SUITE #190	91606	2	177B165  1100	2334011029		South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.18211	-118.39491	First time tenant for management office in commercial building.  Plan check for power and energy - 3891 sq ft. Building permit under 19016-20000-03378.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66257	11041-20001-14750	13421 W VAUGHN ST	91340	7	213B157   435	2523013902	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.27983	-118.4252	Modification to an aproved set of lans.  The modification is the decreasing of the wre size from the load center to the service panel.  The modifications have been clouded.  <<<<solar system 38.6 kw for school>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66258	15041-10000-21663	6344 N SEPULVEDA BLVD	91411	6	180B145   859	2242010028	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.18605	-118.46591	NEW 600 AMP SERVICE FOR EXISTING CARWASH.  RECONNECTING TO EXISTING PANEL A.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66259	17041-10000-11812	1320 E 7TH ST suite 148	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.03598	-118.24041	PC for T24 for TI.  PC includes new lighting for total of 6750 sqft. Load is under 400 A. Building under #17016-10000-09030.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66260	18041-20000-22628	21425 W VANOWEN ST	91303	3	183B105   951	2138011097	(WC)RIVER-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			06/18/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	05/08/2020 12:00:00 AM	ADDRESS	34.19399	-118.59858	Fire alarm system for new 7-story 174-unit apartment building.  (473) devices, (12) remote power supplies, and FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66261	17041-10000-05684	15236 W HARTSOOK ST	91403	4	171A147    84	2263008007	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.1638	-118.46527	PC for roof mounted pv system with 2 inverters and 48 modules with power optimizers. total size 12kw AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66262	15041-10000-20823	865 S FIGUEROA ST 7TH FLOOR	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.04653	-118.26275	T24 FOR EXISTING HIGHRISE BUILDING. REMODELING OFFICES AND PARTIAL HALLWAY. SCOPE OF WORK ON THE 7TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66263	13041-10003-33138	20100 W VIA CELLINI	91326	12	219A115   344	2701039011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	34.2941	-118.57082	"REVISION TO THE APPROVED PLAN. ADDITION OF 60 AMP DISCONNECT. "" 0$ FEE IS DUE TO THE 2012 SENATE BILL NO. 1222"" ((((((((((((((((PV1, Install 8.75 kw DC roof-mounted solar array, interconnect with the service panel.(2)Transformerless inverter(s):Solaredge SE3000A-US and Solaredge SE5000A-US. (35)modules Trina Solar TSM-250PA05.18.)))))))))))))))))))))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66264	17041-20000-28921	21317 W CANDICE PL	91311	12	210B105    23	2706034008	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.27291	-118.59522	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, and (37) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66265	15041-20001-19312	6511 N ORION AVE	91406	6	180B145   559	2234013012	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM			PC Approved	07/06/2015 12:00:00 AM	ADDRESS	34.18901	-118.47076	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 11 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66266	15041-20001-12842	11952-11954 W VENTURA BLVD	91604	2	162B169   153	2369016032	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM			PC Approved	11/05/2015 12:00:00 AM	ADDRESS	34.14327	-118.39243	Changes to an approve set. all changes made under delta 2. Replacing indoor and outdoor lighting. (((Plan check for T.I.  Dental office(Medical Office). Total area: 2082 sq ft. New 400A service upgrade.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66267	15041-10000-25063	9742 W CRESTA DR	90035	5	129B165   862	4307018018	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Expired	10/16/2017 12:00:00 AM	ADDRESS	34.04698	-118.40022	PV1, INSTALL 12.985 KW DC ROO-MOUNTED SOLAR ARRAY ON A SINGEL FAMILY HOUSE.(49) MODULES: KYOCERA KYU2656ZPA(2) INVERTERS: ABB PVI-=5000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66268	10041-10000-00962	15503 W VENTURA BLVD	91436	5	168B141   642	2261039022	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM			PC Approved	01/19/2010 12:00:00 AM	ADDRESS	34.15504	-118.4723	Altaration of lighting in medical office.  This P/C is only for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66269	19041-30001-15549	2902 N HYPERION AVE	90027	4	151-5A205 120	5434027026	C4-1D	Central	Hollywood	Silver Lake		1882.01	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM			PC Approved	10/22/2019 12:00:00 AM	ADDRESS	34.10939	-118.27099	Plan check for t-24 energy only. Changes to an approved set of plans to reflecct field conditions. Note all changes under clouded delta 1. PC only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66270	14041-20001-08352	22676 W HAMLIN ST	91307	12	180B097   404	2038023013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.18879	-118.62171	Expedited plan check per applicant request. (((PV1.  Install 5 kW roof-mounted PV system, connect with main service panel.  Transformerless inverter: SE3800A-US-ZB-U with power optimizers.  20 modules: Canadian Solar CS6P-250PX)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66271	18041-20000-45656	11705 W VENTURA BLVD	91604	2	162B169   335	2368006025	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM			Corrections Issued	11/30/2018 12:00:00 AM	ADDRESS	34.14159	-118.388	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 3,919 sq. ft.Note: Building application has been generated under 18014-30000-06579	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66272	13041-10000-04069	5300 W CENTINELA AVE	90045	11	102B173   102	4103003021	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM			PC Info Complete	02/15/2013 12:00:00 AM	ADDRESS	33.97708	-118.37279	TI IN AN EXISTING EL POLLO LOCO RESTUARANT.  PLAN CHECK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66273	16041-10000-29680	3456 W OLYMPIC BLVD	90019	10	129B189   255	5081026036	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			08/22/2016 12:00:00 AM			Reviewed by Supervisor	09/02/2016 12:00:00 AM	ADDRESS	34.05232	-118.31379	CHANGE OF USE TO MEDICAL OFFICE. DENTAL CLINIC. FULL PC FOR POWER AND ENERGY. CONNECTING TO EXISTING PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66274	14041-10001-29428	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Changes to approved set.  Reduction in the area of scope of work and changes to lighting layout.****Previous Work Description*****Title 24 plan check only.  Total area = 38,400 sq. ft. (outdoor)Installation of new pole lighting for an outdoor parking lot.  One new 400 A panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66275	17041-10002-20496	6060 W HOLLYWOOD BLVD	90028	13	148-5A189 153	5545006030	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.10148	-118.32207	"DELTA 6 CHANGES TO APPROVED PLANS FOR INSTALLING 2 NEW ELECTRIC WATER HEATERS.<<<Supplemental PC for power and energy for office space TI. This permit covers panelboards A, B, D and E which are connected to new 800A service located in adjacent building covered under (17041-10001-20564), feeders and installed at min. 24"" depth to panel F see siteplan. Installing new panels, lights, receptacles and equipment. T24 fees covered under master. B# 17016-40000-11249.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66276	18041-20001-30748	1411 N HIGHLAND AVE unit B	90028	4	147A185   220	5548015037	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	08/22/2018 12:00:00 AM	ADDRESS	34.09649	-118.33888	"8/22/2018first time tenant.  plan check for power and energy.  energy check under master application.this is plan check only for power.  permit fees paid under master application.address correction to reflect unit ""B""((((ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66277	14041-20000-18487	3333 E ALICE ST	90065	1	147A219   302	5454027012	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.09598	-118.22699	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS. TOTAL OF 14 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66278	11041-10000-25537	10201 W PICO BLVD BLDG 29	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	03/15/2012 12:00:00 AM		Permit Finaled	08/14/2012 12:00:00 AM	PIN	34.05182951	-118.41257696	PLAN CHECK FOR NEW ROOF MOUNTED 231.8KW PHOTOVOLTAIC SYSTEM ON FOX STUDIOS BUILDINGS #26 AND BUILDING #29. BUILDING #26 PERMIT UNDER #12041-10000-04678. SATCON INVERTER LOCATED IN BUILDING #29. 532 MODULES ON BUILDING #26 AND 434 MODULES ON BUILDING #29. (1 0F 2). SITE IN METHANE ZONE, NO WORK IN HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66279	16041-20000-16804	6510 N GLORIA AVE	91406	6	180B141   590	2233013014	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.18898	-118.47914	Plan check for PV roof mounted system. System size: 5.0kW and  19 modules and 1 inverter (5.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66280	12041-10000-15822	10376 N GARDEN GROVE AVE	91326	12	204B125   119	2731027028	RE11-1	North Valley	Northridge	Northridge East		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.25853	-118.52979	Plan check for new installation of 11.045KW roof mounted photovoltaic system. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66281	12041-10001-29513	3501 S FIGUEROA ST	90089	9	118-5A201   5	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Approved	12/12/2012 12:00:00 AM	ADDRESS	34.02035	-118.28121	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. VOLLEYBALL BATHROOM, USC CAMPUS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66282	14041-10000-19621	649 N NORTH BROADWAY	90012	1	133-5A215 147	5408016016	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.05987	-118.23972	Low voltage electrical permit. This is a monetary methane for a basement and two story up. Project is a level 5 methane. No penetration through the slab. System is active.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66283	18041-20000-42893	15115 W DOMINO ST	91411	6	177B145   214	2242014005	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.18408	-118.46229	Plan check for PV roof mounted system, system size: 18.15KW  DC, 15.43kW AC with 55 PV Modules and 2 inverters(10kW and 7.6kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66284	19041-30000-14200	801 S FIGUEROA ST 20th Floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Issued	07/26/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the common area corridors on the 20th floor. Project scope is a tenant improvement. Total lighting area  = 1,960 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66285	14041-10001-32975	8559 W EDWIN DR	90046	4	156B169   341	5565044010	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM			PC Approved	12/19/2014 12:00:00 AM	ADDRESS	34.12115	-118.38741	Expedited plan check per applicant request.  PV1.  Install 20 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66286	16041-20001-02885	7900 N BALBOA BLVD BLDG 'G'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	4.13.2016 - Plan check for modifications to approved set. Change size of breakers feeding panels G3, G4, G5, G7, and G8 from 40A to 60A, and update each panel's feeder sizes. Remove T.C. detail from sheet E-5.===Plan check for power and energy Aircraft Hangar Building 'G' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' G' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66287	12041-10003-02589	2411 S 5TH AVE PV1	90018	10	123B189   343	5059021006	RD2-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.035	-118.3226	PLAN CHECK FOR NEW INSTALLATION ROOF MOUNTED 7.03KW  PHOTOVOLTAIC SYSTEM WITH ONE CENTRAL INVERTER AND SIX ENPHASE M215 MICROINVERTERS. ADDITIONAL PERMIT FEE ADDED TO EXISTING PERMIT TO INCLUDE MICROINVERTERS AND COMBINER BOX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66288	13041-20000-23327	13328 W BURBANK BLVD	91401	4	174B157   643	2344014008	R3-1, [Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	ADDRESS	34.17196	-118.42354	Plan check for energy and emergency lighting. Low rise commercial. Padrino's Pizza.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66289	13041-10000-31068	20133 W SHERMAN WAY #5242	91306	3	183B113    24	2114019009	C4-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.20128	-118.57238	NEW FIRE ALARM SYSTEM IN SINGLE STORY RETAIL BUILDING (DD'S DISCOUNT STORE ). ADDITION OF 38 DEVICES, 2 PANELS. FULLY SPRINKLERED, 26919 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66290	19041-10000-11405	1034 N NAPOLI DR	90272	11	129B133   342	4408008006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	07/28/2023 12:00:00 AM	ADDRESS	34.0465	-118.50547	NEW 2-STORY 14,683 Sqr Ft SFD W/ BASEMENT AND ATTACHED RECREATION ROOM WITH A NEW 800 AMP SERVICE. PLAN CHECK ONLY. BUILDING COMBO PERMIT# 18010-30000-02085	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66291	10041-10000-12494	3651 S TROUSDALE PKWY # 320, 330-& 333	90089	8	118-5A201  22	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	ADDRESS	34.01922	-118.28617	LABORATORY IMPROVEMENTS FOR 2727 SQ FT AT LAB SUITE 333, 320, AND 330	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66292	19041-10000-22409	700 W 7TH ST STE S210	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.04797	-118.25815	Energy plan check for a retail interior T.I located on the ground floor of a high rise building.  Scope  includes new lighting and equipment with a total lighting area of 2823 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66293	19041-20000-33990	4194 S CLOVERDALE AVE	90008	10	114B177    98	5029043029	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.0115	-118.36601	Plan check for PV roof mounted system, PV system size: 21.05KW DC, 19.27KW AC with 69 PV Modules and 2 inverters(10KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66294	12041-20000-28066	120 E BROOKS AVE 1-3	90291	11	108A143    32	4286013012	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Apartment			11/21/2012 12:00:00 AM			Verifications in Progress	04/30/2013 12:00:00 AM	ADDRESS	33.99187	-118.47474	Roof mounted P.V. system with battery system. (6.12KWdc)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66295	16041-10000-01407	10945 W BLUFFSIDE DR	91604	2	162B173   267	2366021045	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.14133	-118.36823	T-24, TI TO (E) APARTMENT LOBBY, LEASING OFFICE, FITNESS CENTER & COMMON AREA. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3728.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66296	18041-10000-49192	19943 W RINALDI ST	91326	12	210B113   187	2701040018	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	04/15/2019 12:00:00 AM		Permit Finaled	05/30/2019 12:00:00 AM	ADDRESS	34.27582	-118.56915	Energy plan check for a retail T.I. Scope includes new lighting and equipment with a total area of 2,582-SQ FT.(((INTERIOR SALES TI; REMOVE INTERIOR PARTITION WALLS; NEW NON BEARING PARTITION WALLS; NEW UNDERGROUND ELECTRICAL; NEW LIGHTING; NEW FLOORING, FINISHES AND FURNITURE; NO EXTERIOR; NO PLUMBING; NO MECHANICAL   bld: 18016-10000-40767)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66297	18041-10000-23581	355 S GRAND AVE #1800-1850	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PC FOR OFFICE TI ON THE 18TH FLOOR FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW EQUIPMENT, CIRCUITS AND  LIGHTS.  TOTAL AFFECTED AREA 26405 SQ.FTB# 17016-20000-36402	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66298	18041-20000-41481	4726 E TOLAND WAY	90042	1	154-5A223  30	5474030031	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1862.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.11956	-118.2137	Plan check for PV roof mounted system and energy storage system, PV system size: 3.8kW with 10 modules and with 3.8kW  and 1 LG Chem RESU	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66299	10041-10001-13372	500 S PIER A ST	90744	15	12B193	7440026903		Harbor				9800.31	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			PC Info Complete	07/21/2010 12:00:00 AM				INSTALL A NEW FIRE ALARM IN 500 S. PIER A ST. IN BERTH 161.  THE PERMIT WAS ISSUED UNDER 10041-40000-13372.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66300	19041-20001-35590	11539 N DELLMONT DR	91042	7	213B197    59	2552041022	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.27809	-118.2964	Expedited plan check fee.PV1.  Install 11.2 kW roof mounted grid tied PV system.  (35) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66301	10041-10000-17477	2049 S CENTURY PARK EAST 11TH Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	"TI IN AN EXISTING COMMERCIAL AREA IN ""MERRILL LYNCH"" ON THE 11TH FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS.   VARIANCE WAS SUBMITTED TO SEPERATE THE FIRE LIFE SAFETY SYSTEM."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66302	10041-20000-17894	11723 N FENTON AVE	91342	7	213B165   170	2531009041	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.03	Electrical	Electrical	Commercial			09/09/2010 12:00:00 AM	09/09/2010 12:00:00 AM		Permit Finaled	01/09/2012 12:00:00 AM	ADDRESS	34.28324	-118.39296	Plan check T-24 Energy for outdoor parking lot lights and externally illuminated sign lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66303	19041-10000-52485	200 E WASHINGTON BLVD	90015	9	123A207   186	5127029049	C2-2D-O-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	11/25/2020 12:00:00 AM		Permit Finaled	02/08/2024 12:00:00 AM	ADDRESS	34.03031	-118.26348	FULL PLAN CHECK FOR A NEW 4000A SERVICE TO FEED (2) 1000A RESIDENTIAL SWITCH BOARDS WITH 107 RESIDENTIAL SUBPANELS. SCOPE ALSO INCLUDE (2) 40 HP ELEVATORS, COMMERCIAL AND HOUSE PANELS. TOTAL AFFECTED AREA IS 84352 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66304	14041-20000-32178	17520 W MAYALL ST	91325	12	204B129   413	2734017003	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	02/25/2015 12:00:00 AM	ADDRESS	34.25382	-118.51651	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNECTED WITH MSP.(30) CANADIAN SOLAR CS6P-250P MODULES(1) SE6000 SOLAR EDGE TRANSFORMERLESS INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66305	14041-20000-14002	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	PIN	34.03245819	-118.45766562	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. RIOT HEADQUARTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66306	15041-10000-38263	20011 W VENTURA BLVD	91367	3	174B113   402	2164001022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	PIN	34.17207471	-118.56880689	T-24, TI TO A MEDICAL BUILDING, SCOPE OF WORK INCLUDES NEW LIGHTING ONLY. BUILDING INCLUDES NO OUTPATIENT, NO SURGERY, AND NO OSHPD3 CERTIFICATE. TOTAL SQ. FT. 8753.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66307	18041-20000-00331	7721 N DENSMORE AVE	91406	6	189B141   258	2206010040	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.21091	-118.47732	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from manufacturing to office and warehouse and a tenant improvement. Total lighting area = 3,441 sq. ft.Note: Building application has been generated under 14016-20000-16531 (building permit was reactivated on 8/18/2017).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66308	14041-10000-14929	12244 W HUSTON ST	91607	2	168B165   278	2356010003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.15929	-118.40018	PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFPRMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66309	10041-10000-01443	433 E TEMPLE ST	90012	14	130-5A215 253	5173007901	PF-1XL	Central	Central City North	Historic Cultural		2060.30	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM	04/13/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.05068	-118.23686	Title 24 for two story building and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66310	15041-20000-06562	13301 W KAMLOOPS ST	91331	7	201B157   502	2622013011	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.24673	-118.42298	PV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING 24 MODULES IN TOTAL. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66311	17041-10000-19377	1555 W SUNSET BLVD	90026	13	139-5A209 170	5419028004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1973.00	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			Reviewed by Supervisor	06/23/2017 12:00:00 AM	ADDRESS	34.07667	-118.25669	PC FOR SMALL TENANT SPACE. FIRST TIME TI. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66312	14041-10000-27694	631 E 46TH ST	90011	9	112-5A207 232	5108003022	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Expired	11/01/2016 12:00:00 AM	ADDRESS	34.00174	-118.26459	PV1 Standard Plan, 6.6KW roof-mounted system including (2) inverters, and (30) Kyocera KD255 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66313	17041-10004-26143	5602 W MANCHESTER AVE	90045	11	096B173   123	4125018020	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Issued	01/19/2018 12:00:00 AM	ADDRESS	33.95967	-118.3791	Supplemental for changes to lighting and addition of vacuum system.All changes clouded under delta4. REFERENCE PERMIT # 17016-70001-12791	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66314	19041-10000-35836	1544 S SPAULDING AVE	90019	10	129B177  1191	5069012028	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.04759	-118.36322	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 28 MODULES USING P400 OPTIMIZERS AND ESS (TESLA POWER WALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66315	18041-10000-37424	5353 W IMPERIAL HWY	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93112	-118.37375	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66316	16041-20000-10173	3049 S KERCKHOFF AVE	90731	15	009B197  1617	7465027051	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	33.71611	-118.2899	PV1. ROOFMOUNTED SOLAR SYSTEM. 3KW. MICROINVERTER SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66317	17041-10001-07885	4101 S WESTERN AVE	90062	8	114B193   515	5021031028	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM			PC Approved	05/01/2017 12:00:00 AM	ADDRESS	34.00975	-118.30923	This is plan check only, T-24 LTO per inspector's request. Permit issued under express: 17041-10000-07885	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66318	17041-10000-37306	12552 W SHERMAN WAY 1-14	91605	2	183B161    65	2324034019	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			Reviewed by Supervisor	11/20/2017 12:00:00 AM	ADDRESS	34.20092	-118.40719	FULL PC FOR POWER AND ENERGY FOR A NEW 3-STORY SELF-STORAGE BUILDING(BLDG 2 OF 3). NOTE: THERE ARE THREE BUILDINGS UNDER ONE SET OF PLANS. THIS APPLICATION FOR BUILDING B. SCOPE INCLUDES NEW PANELS, NEW LIGHTS AND RECEPTACLES. NEW CONNECTED LOAD > 400A. B#16010-10000-16920	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66319	19041-10000-35725	11289 W PICO BLVD	90064	11	123B153   210	4260021010	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	07/16/2020 12:00:00 AM	ADDRESS	34.03547	-118.43866	PC FOR ENERGY ONLY TO AN ADDITION AND INTERIOR REMODEL  TO (E) FAST FOOD RESTAURANT. AREA OF SCOPE 1259SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66320	19041-20000-28449	6515 S CRENSHAW BLVD	90043	8	105B185  1291	4006018005	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			07/24/2019 12:00:00 AM	01/20/2022 12:00:00 AM		Permit Finaled	08/25/2023 12:00:00 AM	ADDRESS	33.98009	-118.33113	Full plan check. New 4-story apartment building.  New 800A 240/120V 3ph-4w delta service with panels, lighting, and power loads. Total t24 square footage = 21645 sf	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66321	16041-10000-38650	10450 W WILSHIRE BLVD 1-129	90024	5	135B157   257	4326004181	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			Reviewed by Supervisor	11/10/2016 12:00:00 AM	ADDRESS	34.06558	-118.43053	New fire alarm system in existing 13 story commercial office highrise.  Total system size = 432 devices + 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66322	14041-10000-35435	20127 W NORDHOFF ST	91311	12	195B113    70	2781035015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.23202	-118.57205	T24 ONLY. REMOVING HID LIGHT FIXTURE AND REPLACE WITH LED FIXTURES. TOTAL AREA6201 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66323	10041-10000-23783	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	04/11/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	"INSTALL A NEW CONVEYOR SYSTEM IN TERMINAL 5 OF LAX IN ""OUTBOND BAGGAGE AREA"" TO THE PLANES.  5 NEW MCP'S:  ML1A, ML1B, ML2A, ML2B, R"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66324	19041-20000-42068	1334 W 26TH ST	90732	15	009B193   362	7470001008	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	02/27/2020 12:00:00 AM	ADDRESS	33.72112	-118.3068	Plan check for PV roof mounted and energy storage system, PV system size: 4.35KW DC, 3.8KW AC with 15  PV Modules and 1 inverter(3.8KW) 1 LG Chem and 1 sub-panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66325	18041-20000-21729	20059 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	ADDRESS	34.2756	-118.57118	Plan check for power and energy. Project site is an existing commercial building. Project scope is a first-time tenant to a movie theater. Total lighting area = 38,400 sq. ft.Note: Building application has been generated under 18016-20000-18638	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66326	18041-20001-12682	17701 W REVELLO DR	90272	11	126B117   401	4416020018	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			PC Approved	11/01/2018 12:00:00 AM	ADDRESS	34.04145	-118.56116	11/1/2018changes to an approved set of plans.  changes to add fused disconnects to battery back up and interconnection points.this is plan check only.  ((((Plan check for battery back up system Tesla PowerWall 2.0 connected to existing PV System.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66327	16041-10003-34516	6677 W SANTA MONICA BLVD	90038	4	144B185   674	5532022010	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.09085	-118.33573	This is supplemental plan check only due to design changes.  <<Plan check for Power and Energey for (new) 695 units apartment with 24,900 SF of retail, 5 stories. There are (5) services in compliance with article 230.2(C).>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66328	14041-20000-31288	700 S FLOWER ST 5TH FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	03/10/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING LIGHTING TO EXISTING CIRCUITS.  WORK TO BE PERFORMED IN THE 5TH FLOOR.  2437 SQFT.PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66329	19041-10000-11577	3720 E BOREL ST	90031	1	142-5A227 310	5305013003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.08409	-118.1996	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.265KWdc / 7.60KWac.(29)MODULES-HANWHA Q-CELL Q PLUS BRF-G4.1 285(29)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREGE SE 7600H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66330	16041-20000-29899	8315 W MELROSE AVE	90069	5	141B173   432	5528003003	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.08381	-118.37093	Plan check for power and energy. Project site is an existing commercial building. Project scope is the core and shell for the entire building, which has (3) tenant spaces. Work includes a new 800-amp service and a total lighting area of 9,458 sq. ft.Note: Building application has been created under 16016-10000-08364	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66331	15041-10003-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM			PC Approved	03/24/2017 12:00:00 AM	ADDRESS	34.02201	-118.28947	Change to an approved set by adding panels and circuits on the original plan. All changes under delta_11 only.permit fee is paid under application number 15041-10003-22097.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66332	13041-20000-23643	11950 W LOPEZ CANYON ROAD	91342	7	216B165    24	2526003909	OS-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.28787	-118.40055	New lighting and canopy for a crane.  Load is less than 400, FULL PLAN CHECK is requested by the applicant.  Site is in a METHANE ZONE. Variance filed for methane mitigation under building permit application #13010-20000-02611.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66333	17041-10000-22344	19215 W INGOMAR ST	91335	3	189B117   722	2104007019	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.21211	-118.55189	Installation of roof mounted solar PV system on existing single family dwelling.  Total system size = 11 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66334	15041-10000-04397	14654 W KESWICK ST	91405	6	186B149    38	2210029004	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.21016	-118.45274	Title 24 plan check only.  Total area = 4,352 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66335	16041-10000-17876	619 S KOHLER ST	90021	14	126A213   421	5147031005	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			05/20/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	10/14/2016 12:00:00 AM	ADDRESS	34.03906	-118.24106	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (REYES WHOLESALE PRODUCE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR STORAGE AREAS. TOTAL AFFECTED AREA IS 2252 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66336	13041-10000-27203	8500 W BEVERLY BLVD # 669	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT OF AN (E) 1,893 S.F. RETAIL SPACE IN A COVERED MALL. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66337	18041-20000-35061	3817 N OAK HILL AVE	90032	14	144A231    18	5302023015	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.09055	-118.18556	Plan check for PV roof mounted system, system size: 4.47kW AC, 5.1KW DC with 17 PV Modules and 17 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66338	14041-20000-14756	11959 W CREST PL	90210	2	156B165   159	2382020051	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.12324	-118.39873	New roof mounted PV system with total system size 20.9KW.$0 permit fee is due to state senate bill sb-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66339	15041-10000-21203	7205 N VAN NUYS BLVD	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.20162	-118.44895	"CHANGE OF USE FROM (E) TAKE-OUT RESTAURANT TO ""B"" OCCUP.  RESTAURANT.PLAN CHK IS FOR TITLE 24 ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66340	17041-10000-03898	8721 S MAIN ST	90003	8	096A203   104	6040017023	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	33.95813	-118.27402	Plan check for Title 24 only in existing space, remove outdoor HID lighting fixtures and replace with new LED lighting fixtures. Total area: 28,250 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66341	14041-10000-11919	900 N BROADWAY TEMP2	90012	1	135A215   235	5414013900	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			05/05/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	PIN	34.06407564	-118.23656378	Plan check for tempory power for a mixed used apartment /retail.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66342	14041-10000-06350	11535 W PICO BLVD	90064	11	123B153   508	4260026013	[Q]CM-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.03295	-118.44347	T24, REMOVING EXSITING LIGHT FIXTURES WITH NEW FLORESCENT ONE. TOTAL AREA 1638 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66343	15041-10000-19893	425 W 11TH ST	90015	14	127-5A207 254	5139008010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	07/24/2015 12:00:00 AM		Permit Finaled	08/14/2015 12:00:00 AM	ADDRESS	34.04208	-118.26257	Expansion of fire alarm system in (E) 6-story core and shell building.  120 devices with (E) FACP and annunciator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66344	13041-10000-17753	3465 N BEVERLY GLEN BLVD	91423	4	159B149   272	2275027019	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.13338	-118.44836	ROOF MOUNTED P.V. RESIDENTIAL INSTALLATION.14 MODULES, 14 MICROINVERTERS. 3.024 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66345	17041-10000-19886	1704 W MANCHESTER AVE	90047	8	097-5A193 332	6037014023	C2-1VL, [Q]R5-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM			Corrections Issued	07/10/2017 12:00:00 AM	ADDRESS	33.95981	-118.30702	PC FOR 800A SERVICE. UPGRADED FOR SOLAR, REFEED EXISTING BUILDING LOADS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66346	16041-10003-39052	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	PC FOR CHANGES NOTED DELTA 3 ON PLANS. SCOPE INCLUDES ADDITION OF LIGHT FIXTURE TO THE WEST SIDE STAIRWELL. THIS IS PC ONLY. PERMIT ALREADY ISSUED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66347	19041-10000-30039	13410 W BROWNELL ST	91340	7	213B157    66	2524017011	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.28397	-118.42451	PV1, NEW ROOFTOP MOUNTED SYSTEM, THE SIZE OF THE SYSTEM IS 2.75 KWdc/ 3KWac. SCOPE OF WORK IS 9 MODULES (HANWHA Q-PEAK 305) WITH OPTIMZERS (SE-P320) AND A CENTRAL INVERTER (SE3000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66348	13041-10001-36246	18720 W SAN FERNANDO MISSION BLVD	91326	12	210B121   169	2717007026	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.27361	-118.54153	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR SYSTEM. CENTRAL INVERTER. NON STD PLAN. SYSTEM SIZE 13.08 KW DC.(40) SUNPOWER SPR-327 W MODULES(1) SUNPOWER SPR11401 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66349	18041-20001-32460	10754 W WALNUT DR	91040	7	201B177   119	2542029008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.24984	-118.36466	void.......................pv1install roof mounted pv system sized 12.6KW AC interconnected with msp.  battery bacvk up.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66350	11041-10000-09730	12642 W EMELITA ST	91607	2	174B161   114	2341013018	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2011 12:00:00 AM	07/07/2011 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.17654	-118.4089	11.25 kw photovoltaic system on roof of single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66351	13041-10000-10070	9760 W PICO BLVD 175	90035	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01, 2690.00	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM			PC Approved	05/09/2013 12:00:00 AM	ADDRESS	34.05401	-118.40151	PC FOR ENERGY ONLY. MUSEUM INSP SENT FOR PC ONLY. ANNE FRANK EXHIBIT. 2ND AND 3RD FLOOR EXHIBIT. NO EMERGENCY LIGHTS PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66352	11041-10000-04693	6201 W HOLLYWOOD BLVD	90028		148-5A189  54	5546031001	[T][Q]C4-2D-SN		Hollywood	Hollywood United			Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM			PC Approved	03/10/2011 12:00:00 AM	ADDRESS	34.1018	-118.32461	TEMPORARY INSTALLATION OF EMEGENCY LUMINAIRES AND EXIT SIGNS IN NEW  COMMERCIAL SPACE WHICH IS TO BE SUBDIVIDED INTO TENANT SPACES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66353	14041-10000-01575	1011 S FIGUEROA ST 4TH FLOOR	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.04476	-118.26452	PLANCHECK FOR T24 ENERGY. 4TH FLOOR BROADCAST STUDIO. 4470 SQFT. EMERGENCY LIGHTING IS EXISTING TO REMAIN. ALL WORK IS INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66354	17041-10000-08492	810 E PICO BLVD 135	90021	14	123A211   488	5132019046	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.03119	-118.25079	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL SPACE(RETAIL). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1688 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66355	18041-10000-31034	120 E 68TH ST	90003	9	102B205   300	6011004004	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.20	Electrical	Electrical	Apartment			08/15/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Issued	08/20/2018 12:00:00 AM	ADDRESS	33.97776	-118.27306	Plan check for a expired plan.PV1, roof mounted solar panel, 8.37kw DC / 7.6 kW AC system   (31)modules: SUNEDISON270,   (1)inverter: SE7600A-US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66356	15041-20000-16310	936 S OLIVE ST UNIT 252	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #14 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66357	15041-10000-43387	12871 W BONAPARTE AVE	90066	11	105B157   243	4223013014	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Expired	01/26/2018 12:00:00 AM	ADDRESS	33.98628	-118.42927	PV1 roof mounted installation to a single family home. Inverter : 6.0 kw, (24) Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66358	18041-10000-16441	5636 W FOUNTAIN AVE	90028	13	144B193   111	5536002916	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Expired	10/25/2023 12:00:00 AM	ADDRESS	34.09463	-118.31221	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66359	15041-20000-20981	1654 N ROSCOMARE ROAD	90077	5	147B145    62	4377016017	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	PIN	34.10039039	-118.46172371	PV1. Standard plan. Intall roof mounted PV system sized 9.5 kW. Interconnected with main service panel. (38) LG305N Modules(38) Enphase M250 Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66360	16041-10000-41212	21100 W SHERMAN WAY	91303	3	183B105   225	2112029001	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.20087	-118.59315	REPLACE HID FIXTURES WITH NEW LED FIXTURES T-24 ONLY. Total Area=35550	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66361	16041-10000-03349	11975 W BLUFF CREEK DR	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	33.98224	-118.40247	PC FOR THE ADDITION OF 36 DEVICES TO A FINALED METHANE SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66362	15041-20000-19729	8338 N REMY AVE	91306	3	192B113   485	2781027007	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.22131	-118.57784	PV1. Standard plan. Install roof moutned PV system sized 3.8 kW. Interconnected with main service panel.(12) Solar World Sunmodule SW 285 Modules(1) Solar Edge 3800 Inverter(12) Solar Edge P300 Power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66363	16041-10001-20410	5343 W IMPERIAL HWY	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Info Complete	12/20/2016 12:00:00 AM	ADDRESS	33.93128	-118.37337	12/16/16Changes to an approved set of plans. All changes are clouded under delta 6. Changes include adding a new 1000A 480/277V 3 phase 4 wire distribution board, adding new circuits, revising power and lighting floor layouts, and revising title 24 calculations.FULL PC FOR POWER AND ENERGY FOR AN EXISTING WAREHOUSE BUILDING. SCOPE INCLUDES NEW REFRIGATION EQUIPMENT, EXAUST FANS, AND THREE NEW SUBPANELS. NEW CONNECTED LOAD IS >400A. TOTAL AFFECTED AREA IS 16151 SQ. FT.NOTE: FEES NEED TO BE VERIFIED BY PLAN CHECKER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66364	14041-10000-02387	1417 S BURNSIDE AVE	90019	10	129B177  1116	5069032008	RD2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.04785	-118.35509	PV1, Install 5.83 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel. (1)Transformerless inverter: POWER-ONE AURORA PVI-5000-OUTD-US(22) Modules: SUNIVA OPT265-60-4-1B0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66365	13041-10000-34324	402 W C ST	90744	15	027B205   213	7418035002	[Q]M1-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	33.77236	-118.26611	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.3730 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66366	16041-10000-12731	734 N HENRY FORD AVE	90744	15	030B213   112	7440002034	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	33.78073	-118.24147	New 800A Distribution board 480V, 3-phase on future air products facility. No Connected load at this moment on Panel A (30 A breaker).*Conduit only is filed under supplemental permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66367	15041-20000-19839	20001 W PRAIRIE ST	91311	12	198B113   112	2761040018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.23929	-118.56833	Plan check for PV FIT system. System size: 200kW with 780 modules and 20 inverters(20kW). Voltage class: 480V/3phaseNote: $0 fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66368	15041-20000-00702	13055 W ARROYO ST	91340	7	216B161    38	2514002042	M1-1	North Valley	Sylmar	Pacoima		1042.01	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	05/28/2015 12:00:00 AM	ADDRESS	34.29079	-118.41748	TI TO AN EXISITNG COMMERCIAL WAREHOUSE.  INSTALLING NEW LIGHTING, CONTROLS, CIRCUITS INTO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING. TOTAL SQUARE FOOTAGE 72683	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66369	16041-20000-08346	2595 S HOOVER ST	90007	8	123A201    42	5055022034	C4-1VL-O, QC1.5-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	02/02/2017 12:00:00 AM	ADDRESS	34.03206	-118.28429	Fire alarm plan check. New Fire alarm system for a NEW 4-STORY MIXED USE BUILDING ( APARTMENT AND  OFFICE / RETAIL ) WITH ONE LEVEL BASEMENT PARKING GARAGE. 148 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66370	16041-20000-06836	5871 W PICO BLVD	90035	5	129B173   378	5086003027	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM			PC Approved	06/30/2017 12:00:00 AM	PIN	34.05187718	-118.3671302	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 3,694 sq. ft.Note: Building application has been generated under 16016-20000-04226	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66371	13041-10000-14861	1644 S BENTLEY AVE 1-9	90025	5	129B153   667	4324032009	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			06/06/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.04864	-118.44372	New five story 9-unit condo.  Power and energy full plan check.  Methane zone.  Modification to separate fire alarm plans filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66372	19041-10000-46923	146 N ORANGE DR	90036	5	138B181   629	5513005008	R2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.07497	-118.34174	NEW ROOF MOUNTED 3.3KW PV SYSTEM WITH 10 @ (330W) PV PANELS AND OPTIMIZER AND ONE 3KW CENTERAL INVERTER ON A DUPLEX BULDING .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66373	15041-20001-32841	7216 N TOPANGA CANYON BLVD 1st floor	91303	3	183B101    43	2111022007	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	34.20154	-118.60569	T24 PERMIT FOR INSPECTION OF LIGHTING. MASTER PERMIT COVERED TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66374	15041-20000-04472	1426 N SUMMITRIDGE DR	90210	5	147B157   404	4355007045	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Expired	04/12/2017 12:00:00 AM	ADDRESS	34.09627	-118.42005	PLANCHECK FOR POWER FOR (N) SFD W/ ATTACHED GARAGE 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66375	14041-20000-17300	669 W 34TH ST 3RD FLR	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	PIN	34.02214675	-118.28186522	TI for replacing exsiting fluorescent lighting with new LED lighting in a partial area with 2028 SQ feet on a USC school commerical building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66376	14041-20001-27258	8827 N OAK PARK AVE	91325	12	195B133   268	2690012009	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.23112	-118.50561	expedite per customer request.install roof mounted pv system sized 7.6kw interconnected to msp.(30) solar world modules(30) power optimizers(1) solar edge 7600 inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66377	14041-10000-30280	8101 N LANKERSHIM BLVD	91605	6	189B169    86	2310007014	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			10/31/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.21755	-118.38798	Energy plan check for  retail show room in a commercial building.total area 2746.  (propeller showroom)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66378	13041-10000-36029	5219 N NORWICH AVE	91411	4	172-5A147 232	2250019026	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.16547	-118.46087	PV1, Install 4.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (17) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66379	15041-20000-09694	6316 N TOPANGA CANYON BLVD #1180	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/02/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and energy for first time tenant New Restaurant. Total area: 2,666 sq ft. Building Permit # 13010-10000-02905	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66380	19041-10000-47732	407 E 120TH ST 1-3	90061	15	084B205  1139	6083029027	R3-1XL-CPIO	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Issued	12/23/2019 12:00:00 AM	ADDRESS	33.92385	-118.26736	INSTALLING A NEW 600AMP SECTION AND 600AMP BREAKER AND UTILITY METER TO AN EXISTING 600AMP 120/240V SERVICE. NEW SECTION RATED TO EXISTING AIC RATING OF 65K, AND REESTABLISHING BONDING AT NEW METER SECTION	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66381	16041-20000-21819	7952 N VAN NUYS BLVD	91402	6	189B149   634	2212028020	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.21568	-118.44851	Plan check Title 24 only in exiting space T.I. Blaze pizza  Total area: 2,245	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66382	14041-10001-21996	4425 N KATHERINE AVE	91423	4	165B153   156	2265018018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM			Reviewed by Supervisor	09/03/2014 12:00:00 AM	ADDRESS	34.15159	-118.44336	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(12) MODULES: KYOCERA KD 255GX(1) INVERTER: POWER-ONE AYRORA PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66383	16041-10000-32214	3470 W 6TH ST 9-10	90020	10	135B197  1134	5502029026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM			PC Approved	09/12/2016 12:00:00 AM	ADDRESS	34.06339	-118.29748	T-24, PC FOR ENERYG ONLY. COMBINE SUITES 9 AND 10 TO CREATE ONE RESTAURANT SPACE. SCOPE INCLUDES NEW LIGHTS AND RESTUARANT FOR A PART NEW AND EXISTING RESTUARANT. TOTAL AFFECTED AREA IS 1155 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66384	10041-10000-24535	13488 W MAXELLA AVE	90292	11	105B153    78	4212004012	[T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Public Safety Only			12/09/2010 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	New fire alarm sytem for an appartment building. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66385	16041-30000-40300	420 S BURLINGTON AVE	90057	1	133-5A205 218	5153003005	R4-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.05983	-118.2697	Plan check for Power and energy for Existing Hotel Renovation 2 story building 15 rooms with kitchen. Total area: 2,040 sq ft B#: 16016-30000-12353	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66386	18041-30000-12899	8620 S AIRPORT BLVD	90045	11	096B169   631	4125009020	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Issued	11/13/2018 12:00:00 AM	ADDRESS	33.95899	-118.38536	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the ground floor. Total lighting area = 6,000 sq. ft.Note: Building application has been generated under 17016-30001-05804	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66387	12041-10000-17435	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	02/18/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check power and to provide conduit stubs for future (core & shell) concession tenants at Tom Bradly (TBIT). TI to existing fire alarm system on seperate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66388	14041-20000-13135	4363 N IRVINE AVE	91604	2	165B169   407	2365021015	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.14912	-118.38569	PV1.  Install 9.18  kW roof-mounted utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66389	15041-10000-43912	19851 W NORDHOFF PL 105	91311	3	186B125   829	2118015010	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.23624	-118.56649	TIT O AN EXISTING COMMERCIAL BUILDING.  REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 13684	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66390	12041-10000-01809	1010 N GALLOWAY ST	90272	11	129B129   658	4423012003	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2625.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.04769	-118.52108	PLAN CHECK NEW 5.6KW ROOF MOUNTED PHOTOVOLTAIC SYSYEM FOR SINGLE FAMILY DWELLING. PERMIT FOR  PV INSTALLATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66391	14041-20001-13339	4645 N WESTCHESTER DR	91364	3	168A111    82	2174012004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.15468	-118.58327	Expedite per customer request9.5kw PV1 roof-mounted system with (2) transformerless  Solaredge # SE3800A-US inverter, Solaredge  power optimizer P300, and (36) Trina Solar #TSM-250PA05.18 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66392	11041-10001-01902	10123 W RIVERSIDE DR Suite #-A	91602	4	165B181    38	2424008015	[Q]C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.15238	-118.35147	REMODEL AN EXISTING 2,442 SQFT TO A COUNTER BURGER RESTAURANT , NO ALCOHOL BEVERAGES WILL BE SERVED , SOLD , OR CONSUMED ON OR AROUND PREMISES, MAX. 3-EMPLOYEE PER SHIFT.  changes made to previously approved set change of fixture.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66393	17041-30000-06391	11269 W CAMARILLO ST	91602	2	168B173   462	2353024090	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Apartment			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.15779	-118.37678	Plan check for a fire alarm system for a 14-unit apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (56) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66394	11041-10000-14814	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	09/25/2012 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	Renovation and addition to existing Tom Bradley International Terminal building, LAX.  PLAN CHECK IS FOR POWER AND ENERGY.   FIRE ALARM IS ON A SEPERATE APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66395	16041-10000-44114	2174 W 30TH ST	90018	10	120B189   374	5052025011	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.02728	-118.31431	Plan check for PV roof mounted system. System size: 3.6kW with 16 modules KYOCERA ADN 1 INVERTER ABB #PVI-3.6-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66396	12041-20000-06874	127 S SAN VICENTE BLVD Bulletin-160 TI	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 160  TI  plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66397	13041-10000-07319	7014 N JUMILLA AVE	91306	3	183B117   472	2135017002	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.19793	-118.56324	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.39 KW. USING 22 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66398	16041-10001-38638	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	05/22/2020 12:00:00 AM	ADDRESS	34.16935	-118.53104	CHANGES TO APPROVED SET OF PLANS DELTA 3 AND 4 ONLY - CHANGES INCLUDE REMOVAL & ADDITION OF NEW LOADS, RELOCATION OF EXISTING EQUIPMENT, EGRESS LIGHTING MODIFICATION DUE TO FIELD CONDITIONS, ALTERATIONS TO T24, AND UPDATE TO LOAD CALCULATIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66399	18041-20000-17418	11015 N LOUISE AVE	91344	12	210B133   673	2696002009	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.27014	-118.51122	Plan check for PV roof mounted system with battery backup, system size: 7.6kW with 24 modules and 1 inverter(7.6kW) connected to LG battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66400	11041-10000-05387	2806 N FIGUEROA ST	90065	1	142-5A221 178	5446017036	[T][Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1990.00	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.08483	-118.22085	Fire alarm 46 devices, fire alarm plan approved by FD. two story building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66401	18041-10000-34638	199 N ASHDALE AVE	90049	5	138B145   254	4366009013	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Expired	09/06/2023 12:00:00 AM	ADDRESS	34.07496	-118.46347	Permit fee is $0.00 due to Senate Bill 1222.NEW ROOF MOUNTED 9.1KW PV SYSTEM WITH 28 PV MODULES PLUS 27KW ENERGY STORAGE SYSTEM ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66402	11041-10000-17474	828 S BROADWAY	90014	14	127-5A209 180	5144016062	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM			PC Approved	08/17/2011 12:00:00 AM	ADDRESS	34.04298	-118.2552	REMODEL EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66403	19041-10000-53093	6040 W SUNSET BLVD 6TH FLOOR	90028	13	147A189   228	5545013403	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.0978	-118.32068	TI IN OFFICES-PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66404	13041-20000-19901	5815 W SUNSET BLVD BLDG C-STE 210	90028	13	147A191    48	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM			PC Approved	07/26/2013 12:00:00 AM	ADDRESS	34.09822	-118.31613	owner lost plans. new plan check and application #. t24 energy only. Plan check for energy and emergency lighting. Not a first time tenant per applicant. Photoshop. Building C, Suite 210. Kensington	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66405	16041-20001-19166	3411 E ESTRADA ST	90023	14	120A225   371	5190017037	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.02081	-118.20481	Expedite per applicant request. {{{{Plan check for PV roof mounted system. system size: 5.0kW with 18 modules and 1 inverter(5.0kW)}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66406	14041-10000-07870	101 S LA BREA AVE	90036	5	138B181   853	5513019015	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	06/03/2014 12:00:00 AM	ADDRESS	34.07338	-118.34425	IN EACH OF THREE TENANT SPACES, INSTALLATION OF TWO PANELBOARDS, 45KVA TRANSFORMER AND AC UNIT AND CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66407	11041-10000-25664	15220 W ANTELO PL	90077	5	159B145   589	4378005008	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	01/13/2012 12:00:00 AM	ADDRESS	34.12922	-118.46269	New 8.36kw rooftop photovoltaic system for a single family residence.  44 new modules and one inverter to a 400A bus.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66408	13041-10000-18438	16011 W GLEDHILL ST	91343	12	198B141   128	2671014033	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	09/09/2013 12:00:00 AM	ADDRESS	34.24203	-118.48111	ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. 1 INVERTER (DC UNGROUNDED) SOLAR EDGE #SE3800A. 16 MODULES #TRINA TSM-245PC05, WITH USAGE OF POWER OPTIMIZER OP250-LV OP300-MV	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66409	13041-20000-31149	13079 W CHANDLER BLVD	91401	4	171B161    87	2345012007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.16873	-118.41784	THIS APPLICATION IS FOR NEW T24 ENERGY PLAN CHECK ONLY. NOT A PC FOR CHANGES TO APPROVED SET. NEW APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66410	16041-20000-19514	402 N KENMORE AVE	90004	13	138B197    73	5520016010	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.07788	-118.29679	PV1INSTALL ROOF OUNTED PV SYSTEM SIZED 3.8KW.  STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66411	16041-20000-03757	7347 N ATOLL AVE	91605	2	186B157   409	2327001020	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	04/29/2016 12:00:00 AM	ADDRESS	34.20424	-118.42119	Plan check for energy only. T.I. to combine two buildings into one and change the use from manufacturing into distribution/warehouse. New lighting (incl. emergency) and receptacles. Sqft: indoor- 5,600; outdoor- 11,200; total- 16,800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66412	17041-10000-09508	6570 W 86TH PL	90045	11	096B165   667	4122013011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	ADDRESS	33.9592	-118.40408	PC for energy only, outdoor only. Removing HID fixtures and replacing them with new LED ones. Area: 5,125.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66413	14041-10001-09424	7844 N CLEON AVE	91352	2	189B173   509	2409009003	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.21332	-118.36801	(((EXPEDITE FEES)))P V1 ROOF MOUNTED TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. TOTAL SYSTEM SIZE 5.0KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66414	16041-10001-23960	2409 N GRIFFITH PARK BLVD	90039	4	148-5A205  38	5432003004	RD2-1VL, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1951.00	Electrical	Electrical	Apartment			12/26/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.10303	-118.27254	PC for changes to approved set. Installing exit sign. All changes clouded under delta 2. Additional exit sign to be installed on roof level stairwell entrance see note on E2.24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66415	16041-20000-41870	16551 W SAN FERNANDO MISSION BLVD	91344	12	210B137   414	2681016011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.27212	-118.49285	Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP.6kW ungrounded system. (20) 320W pv modules. Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66416	16041-10002-33506	2327 W 37TH ST	90732	15	009B185    10	7563031011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2017 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	33.72338	-118.32705	Changes to approved set.  Remove 2 modules from new rooftop solar PV array.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66417	13041-10000-04063	11906 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM			PC Info Complete	02/15/2013 12:00:00 AM	ADDRESS	34.05239	-118.47055	TI IN AN EXISTING COMMERCIAL AREA.  PLAN CHECK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66418	14041-10000-09412	8446 N O'MELVENY AVE	91352	6	192B169   359	2633033010	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.22384	-118.39062	PV1 3.25KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(13)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66419	17041-10000-11641	12832 S VERMONT AVE	90247	15	081B197   374	6117022028	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	33.91561	-118.29143	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 10710 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66420	14041-20000-17429	10100 W SANTA MONICA BLVD 6th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI to (E) commercial office space in highrise commercial office building.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66421	14041-10000-01224	1458 S SAN PEDRO ST # 149	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK IS INDOORS. 720 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66422	16041-20001-12899	7071 N VINELAND AVE	91605	2	183B173   142	2319002018	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Approved	04/28/2016 12:00:00 AM	ADDRESS	34.19929	-118.37051	04/28/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the lighting floor plan.*****Previous Work Description*****Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,910 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66423	17041-20001-22505	2737 N CHADWICK CIR	90032	14	141A233   255	5217004022	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.07933	-118.17608	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.72 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66424	15041-10000-11216	3538 N COPELAND PL	90032	14	142-5A237  39	5219022026	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	34.08652	-118.16536	PV1, INSTALL 6.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, TIE WITH MAIN SERVI E PANEL. (25) MODULES: KYOCERA KU2606XPA, (1) INVERTER: PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66425	17041-10000-18814	10250 W SANTA MONICA BLVD # 1853	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	08/24/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	First tenant-Allsaints- in retail space # 1853	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66426	13041-10000-03248	1510 N STANLEY AVE	90046	4	147B177   938	5550006023	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Permit Finaled	06/20/2013 12:00:00 AM	ADDRESS	34.09848	-118.35597	PLAN CHECK POWER AND ENERGY FOR AN ALTERATION OF EXISTING RESTAURANT. PLACE OF ASSEMBLY (OVER 100 OCCUPANTS). 5302 SQUARE FEET..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66427	19041-10000-48415	14845 W VENTURA BLVD	91403	4	168A149   189	2264017026	(Q)C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM	ADDRESS	34.15238	-118.45654	NEW FIRE ALARM SYSTEM WITH 170 DEVICES, 4 POWER SUPPLIES, 1 COMMUNICATOR, 1 ANNUNCIATOR WITH 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66428	15041-20000-11889	12457 W OSPREY LANE Unit 1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.97937	-118.41024	Plan check for PV1 roof mounted  system 8 modules (SUNPOWER MODULES SPR-230NE-LK-D) and 1 inverter(SB3000TL -US-22)PV clearance shall apply to Unit #2 and #3 of address 12457 Osprey Lane	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66429	14041-10000-16607	201 N FIGUEROA ST 9TH FL	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI TO EXISTING HIGHRISE BUILDING. UPGRADING EXISTING DISTRIBUTION EQUIPMENT AND MOTORS WITH SOME NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66430	19041-20000-42567	2633 S MAIN ST	90007	9	120A205    78	5122001020	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	07/02/2020 12:00:00 AM	ADDRESS	34.02408	-118.2694	Plan check for Title 24 energy only for new lighting, Total load less than 400A. Total lighting area: 12521 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66431	14041-20000-00538	9301 N OAKDALE AVE	91311	12	198B113   113	2761040019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.23936	-118.56702	pc for ti, existing office new lighting. pc for t24 energy only. express permit to be issued from this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66432	10041-10001-25739	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/06/2011 12:00:00 AM	ADDRESS	34.04842	-118.33486	rEVISIONS TO PERMITTED SET OF PLANS. INCLUDES SOME LUMINAIRES RELOCATED TO CLEAR DUCTWORK; REVISED BUSWAY LOCATIONS;REVISED OVERRIDE SWITCHES RENAMED PANEL RP4 TO HVAC3. PLAN CHK ONLY((((((((  New electrical for Lowe's.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66433	17041-10000-16227	3201 S HOOVER ST STE 1820	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.0255	-118.28448	CHANGE OF USE OF PORTION OF CORE SHELL RETAIL SPACE INTO NEW COFFEE SHOP WITH UNCOVERED OUTDOOR DINING. PC FOR POWER AND ENERGY FOR FIRST TIME TI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66434	14041-20002-14002	12333 W OLYMPIC BLVD	90025	11	123B149   503	4259019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	PIN	34.03245819	-118.45766562	[[1/29/15  CHANGES TO APPROVED SET PER INSPECTORS REQUEST TO UPDATE PLANS. REMOVING DISCONNECT SWITCH FOR THE OPTIONAL STANDBY EMERGENCY GENERATOR ONLY . DELTA 6 CHANGE ONLY]]]]]SUPPLEMENTAL TO REMOVE AND REPLACE LIGHTING FIXTURES ON BUILDING NO. 4PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. RIOT HEADQUARTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66435	13041-10000-28869	3901 N EAGLE ROCK BLVD BLDGE	90065	13	154-5A217 333	5460001042	[Q]RAS3-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			Reviewed by Supervisor	11/20/2013 12:00:00 AM	ADDRESS	34.11925	-118.23127	"INSTALLING FIRE ALARM SYSTEM,   APARTMENT BUILDING ""E"" (5 OF 7 buildings)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66436	19041-10000-44017	11429 W BIONA DR	90066	11	114B157   347	4234008038	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	11/16/2019 12:00:00 AM	ADDRESS	34.01094	-118.42283	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 12 (POWER XT-360R-PD) MODULES, 12 (P370) OPTIMIZERS,  1 (SOLAR EDGE SE3800H-US) INVERTER, CONNECTED TO AN EXISTING 200A PANEL. SYSTEM SIZE IS 4.32KW DC AND 3.80KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66437	14041-10004-26098	7635 N SEPULVEDA BLVD	91406	6	186B145    74	2222013012	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			PC Approved	01/21/2015 12:00:00 AM	PIN	34.20935369	-118.46682857	Change to approved set by replacing lighting control system , keynotes, symbol legend and updating panel schedule. Note, all changes apply to delta-5 only. (((Plan check for power and energy. 2013 standards. renovation of a tool retail store. Service, Panels, and transformers are existing to remain.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66438	18041-20001-18391	1260 N PIEDRA MORADA DR	90272	11	135B121     6	4431033003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Issued	08/20/2018 12:00:00 AM	ADDRESS	34.07002	-118.55144	Change of system size to 14.19 kW DC/13.05 kW AC.  (2) modules added for a total of (43) modules.  $0 permit fee per State Senate Bill SB 1222 as modified and extended by State Assembly Bill AB 1414.  (((PV1.  Install 13.58 kW DC/12.44 kW AC roof mounted grid tied PV system.  (41) modules with 11.4 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66439	18041-10000-46337	6550 N VAN NUYS BLVD	91401	6	180B149   515	2237013906	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	05/06/2019 12:00:00 AM		Issued	05/06/2019 12:00:00 AM	ADDRESS	34.18983	-118.44839	Plan check for a PV2 84kw AC carports mounted system LADWP FIT program. Scope includes (280) modules and (2) inverters interconnecting through a dedicated service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66440	11041-10001-20811	8500 W BEVERLY BLVD # 628	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM			PC Approved	12/06/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	DELTA 3 REVISION TO T24 ENERGY APPROVED PLANS ONLY. REVISE RESTROOM LAYOUT AND T24 INSTALLED WATTAGE CALCULATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66441	19041-20000-44842	20348 W BALTAR ST	91306	3	189B113   358	2107009008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.21645	-118.57715	Plan check for PV roof mounted system, PV system size: 3.1KW with 10 PVModules an 1 inverter(3.8KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66442	17041-20000-35995	7851 N MARY ELLEN AVE	91605	11	120B157   631	4250022020	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	11/27/2017 12:00:00 AM	ADDRESS	34.21329	-118.41784	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66443	19041-20001-31166	5550 N EL CANON AVE	91367	3	174B089   536	2046017001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	34.17078	-118.64807	EXPEDITED.PV1. INSTALL (37) ROOFMOUNTED AC MODULES ON NEW SERVICE. SYSTEM SIZE IS 14.80 KWDC AND 13.46 KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66444	18041-10000-07319	3208 N HUMBOLDT ST	90031	1			MR1-1	East Los Angeles				1992.01	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	05/16/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.08254	-118.21583	DESIGN BUILD, INSTALLATION OF NEW PANELBOARDS, MACHINERY, CIRCUITS, AND AC UNITS AT A MANUFACTURING PLANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66445	14041-20000-34163	7557 S WESTLAWN AVE	90045	11	099B161    22	4110027002	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2014 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	33.97126	-118.41117	PV1.  Install 5.3 kW DC roof-mounted, utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66446	11041-20000-10976	117 E WINSTON ST	90013	9	129A213   226	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Apartment			05/27/2011 12:00:00 AM	05/27/2011 12:00:00 AM		Permit Finaled	05/21/2012 12:00:00 AM	ADDRESS	34.04713	-118.24718	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66447	15041-20000-35612	413 N AVENUE 52	90042	1	151-5A225  32	5469017028	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.11109	-118.20278	PV1 SFD TOTAL SYSTEM SIZE 4.2 KW AC USING CENTRAL INVERTER SYSTEM. USING TOTAL OF 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66448	14041-10000-16580	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM			Reviewed by Supervisor	07/09/2014 12:00:00 AM	ADDRESS	33.94502	-118.40714	TI for restrooms in terminal 3.  Plan check for power and lighting.  Total area = 4,817 sq. ft.Provide lighting, electrical distribution, and power for 12 renovated restrooms in LAX.Note: Title-24 2013 forms have been used, this project is under 2008 energy code.  Fire alarm work is done by seperate conractor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66449	14041-20000-29012	4835 N OAK PARK AVE	91316	5	168B133   168	2289004009	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2014 12:00:00 AM			PC Approved	10/20/2014 12:00:00 AM	ADDRESS	34.15873	-118.50467	Changes from previously approved PV plans (1441-20000-26081).  Change in circuit breaker rating from 75A to 70A.Note: Permit is under a separate application.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66450	11041-10001-23112	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			04/13/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.09676	-118.29487	18 fire alarm panel and96 devices. back bone instalation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66451	12041-10000-30674	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM			Corrections Issued	12/20/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	T24 INTERIOR TI TO EXISTING CAFE. 1 STORY STANDALONE 1575SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66452	06041-10013-09913	1633 N LA BREA AVE	90046		147B181   287	5548008010	C4-1VL-SN		Hollywood	Hollywood Hills West			Electrical	Electrical	Apartment			10/13/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	34.10058	-118.34527	DELTA 14 REVISIONS TO APPROVED SET OF PLANS- CHANGES TO EXTERIOR LIGHTING SYSTEM; ADDITIONAL LIGHTING CIRCUITS, AND REPHASING AND BALANCING OF LOADS.Variance to run the equipment grounding conductor outside and wrapped around parallel runs of MC cable submitted.  <<<<Original Plans were submitted May 2006.  Verify OLTG for controls and efficency.>>>>> ((((Per B.H. plan is excepted from OLTG calcs but not controls))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66453	18041-10000-13876	5013 N LANKERSHIM BLVD	91601	2	171B173  1230	2353011002	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.16116	-118.37259	PC FOR FIRST TIME TENANT FOR A BAR TOTAL CONNECTED LOAD <400A. SCOPE INCLDE NEW PANLES, CIRCUITS, LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 1350 SQ	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66454	17041-10001-41805	644 S GLADYS AVE	90021	14	126A213   413	5147030064	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.03913	-118.24292	CHANGES TO APPROVED PLANS FOR CHANGING TYPES AND NUMBER OF MODULES.198 X 340W MODELES WERE CHANGED TO 176 X 340W + 24 X 310W FOR  TOTAL OF 200 PV MODULES. ALL CHANGES UNDER DELTA-1 ONLY.PV2, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND STEP DOWN TRANSFORMER TO 240V. (200) MODULES (3) 20KW INVERTERS. TOTAL SYSTEM SIZE IS 59.4 KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66455	16041-20000-23916	715 S KINGSLEY DR	90005	10	132B193   367	5093021024	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.05927	-118.30321	$0 permit fee is due to State Senate Bill SB 1222PV2.  Install 59.8 kW DC roof-mounted PV system.  (176) modules with (4) 10kW transformerless central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66456	16041-10000-32264	14835 W ASTORIA ST	91342	7	219B149   414	2506035035	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	Apartment			09/12/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.29747	-118.45476	PV2. ROOF-MOUNTED SOLAR SYSTEM ON EXISTING RESIDENTIAL APARTMENT BUILDING. SYSTEM SIZE: 3.840 KW DC / 3.80KWac12 CANADIAN SOLAR CS6X-320 MODULES1 SMA AMERICA SB 3800TL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66457	19041-20000-22478	11637 N DELFT LANE	91342	7	213B169  1017	2530001018	(T)RU-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.28215	-118.38453	PV1.  Install 5.25 kW DC roof mounted grid tied PV system.  (15) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66458	15041-20000-43784	15208 W VENTURA BLVD	91403	4	168B145  1166	2276007059	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Expired	01/30/2018 12:00:00 AM	ADDRESS	34.15329	-118.46435	Plan check for Title 24 only; replace 3 light fixtures. Total area; 293 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66459	16041-10000-22176	1100 S GLENDON AVE #700	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.06074	-118.44418	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE. TOTAL AFFECTED AREA IS 7936 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66460	16041-10001-27236	660 S FIGUEROA ST	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	REVISED SINGLE LINE DIAGRAM TO SHOW AS-IS INSTALLATION: THE SWBD IS NOT CONTINUOUS; ALL FEEDERS SHOWN ARE NEW AND EXISTING; LESS THAN SIX MAIN DISCONNECTS; NEW FEEDER IS LESS THAN 10FT; UPDATE AIC RATING OF THE SERVICE EQUIPMENT.(((((((((Plan check for power only.  Installation of new 480/277 V 1,200 distribution board to feed two future restaraunt tenants.  Distribution board ties in to existing electrical system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66461	16041-10001-13169	333 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   594	2424044021	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	12/23/2016 12:00:00 AM	ADDRESS	34.13838	-118.35964	TITLE 24 FOR EXISTING HOTEL (TI INCLUDES :INTERIOR REMODEL OF ( E ) 21- STORY HOTEL  . ( 457 GUEST ROOMS )). SCOPE OF WORK INCLUDES CHANGING GUEST ROOM LIGHTING AND LIGHTING IN CORRIDORS IN FLOORS 4-20. NOTE: EMERGENCY LIGHTING TO REMAIN IN PLACETOTAL SQ FT. 18928TITLE 24 UNDER APPLICATION 16041-10001-13169	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66462	12041-20000-28773	1339 N GENESEE AVE	90046	4	147B177  1341	5551029009	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	01/29/2013 12:00:00 AM	ADDRESS	34.09552	-118.3583	Enphase system on roof of single family dwelling with photovoltaic subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66463	16041-20001-24811	17116 W KNAPP ST	91325	12	198B133   406	2692020039	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.2383	-118.50633	Expedite per applicant request{{{{Plan check for PV roof mounted system. System size: 12kW with 60 module and 2 inveters(6.0kW)}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66464	15041-10001-35591	1105-1107 E 113TH ST	90059	15	087A209   285	6072023019	R2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	33.93199	-118.2564	"Original permit was pulled online under SFD (15041-90000-35591).  PC is requested per inspector as well as work description to be ""PV installation on Duplex"".(30) SP 327 modules(2) PVI-4.2-OUTD(1) load centerAddress has been revised to reflect 1105-1107 E. 113th St.Note: Fees are low due to senate bill 12222."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66465	17041-20000-24364	8828 N CANBY AVE	91325	12	195B125   474	2769026006	R2-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.23156	-118.53466	PV1.  Install roof mounted PV system sized 4.5 kW intercomnnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66466	17041-10000-25487	17471 W VENTURA BLVD	91316	5	171B129   403	2257016054	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Issued	07/27/2017 12:00:00 AM	ADDRESS	34.16158	-118.51331	PC for T24 only for new lighting in cleaners. PC for new lights. Total affected area 2300 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66467	15041-10000-30198	745 S CRENSHAW BLVD	90005	4	132B189   342	5090032016	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.05951	-118.32046	PV1 5.0KW AC roof-mounted system with (16) Sunpower SPR327 modules and (1) SMA SB-5000TL inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66468	14041-20000-24839	7010 S HOOVER ST Unit #6	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97574	-118.28691	pv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #6. total system size 1.25kw AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66469	11041-10000-07719	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	07/18/2011 12:00:00 AM	PIN	33.94363002	-118.42513364	AT THE FEDEX EXPRESS M./C NO3 HANGER, ALTERATIONS IN SOME OFFICES AND WORK AREAS- ADDING OCCUPANCY SENSORS PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66470	16041-20001-32813	16659 W ADDISON ST	91436	5	171B137   121	2259003032	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2016 12:00:00 AM			PC Approved	10/17/2016 12:00:00 AM	ADDRESS	34.16405	-118.49648	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (36) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66471	11041-10000-16532	11100 W SANTA MONICA BLVD 7TH FL	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM			PC Approved	08/05/2011 12:00:00 AM	ADDRESS	34.04726	-118.44465	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66472	15041-10000-16414	11818 W WILSHIRE BLVD UNIT 300-PHASE 2	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.0474	-118.46308	PHASE 2:REMODEL OF THE CURRENT TENANTS IN VIRTO FERTILIZATION (IVF) LAB AND ADJACENT AREA IN MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66473	18041-20001-23612	10073 W MCBROOM ST	91040	7	207B181    55	2543008012	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM			PC Approved	07/05/2018 12:00:00 AM	ADDRESS	34.26391	-118.35048	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWac and consists of (42) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66474	17041-10000-32807	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	33.94221	-118.40701	T-24 ENERGY CALCS FOR REPLACING EXISTING LIGHTS IN SPACE 4F IN TERMINAL 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66475	18041-10000-01312	17331 W TRAMONTO DR Bldg # 4	90272	11	126B117   411	4416023***	RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			01/18/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Issued	04/09/2018 12:00:00 AM	ADDRESS	34.04152	-118.55501	PC FOR NEW FIRE ALARM  IN BUILDING 4 (CAMPUS STYLE)SCOPE INCLUDES 108 DEVICES AND 2 PANELS. SPECIFIC ADDRESS PROVIDED IN BUILDING PERMIT UNDER SCOPE OF WORK. MAIN FACP AND ANNUNCIATOR PANELS CURRENTLY LOCATED IN GUARD HOUSE.B#16010-10001-00078BUILDING 4  (PLAN B1/ B1R)  8 UNITS AND 4 STORY  TYPE IIA  APARTMENT  BUILDING WITH  TYPE IB GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66476	18041-10000-11523	21403 W SHERMAN WAY	91303	3	183B105   142	2111017040	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.20119	-118.59794	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66477	13041-10000-08774	11400 N PORTER RANCH DR	91326	12	213B113   299	2701040019	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM			PC Approved	04/05/2013 12:00:00 AM	ADDRESS	34.27643	-118.57008	T24 FOR EXISTING RESTAURANT SPACE IN THE BAR AREA ONLY. 442 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66478	14041-20000-15122	7130 N GATESHEAD WAY	91307	12	183B093   178	2028023011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.19952	-118.63986	New roof mounted PV system with optimizer and transformerless inveter.  Total system size11.1KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66479	17041-20000-01484	523 W 6TH ST SUITE 534	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 5TH FLOOR. SUITE 534.  13,978 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66480	16041-20001-04342	16300 W SHADOW MOUNTAIN DR	90272	11	132B121   218	4420039003	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	34.05841	-118.5395	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (34) modules, (1) inverter, and (1) combiner box. System is being interconnected with a 600-amp main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66481	09041-20005-15447	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM			PC Approved	11/23/2010 12:00:00 AM	ADDRESS	34.27548	-118.56626	series rated j fuse and breakers on refrigeration racks by inspector doug verral	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66482	19041-10000-26133	505 W 31ST ST	90007	9	120A203    80	5123020009	C2-1L	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	08/26/2021 12:00:00 AM	ADDRESS	34.02382	-118.27755	PC for new fire alarm, seven floors for apartment building. 245 devices and 1-facp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66483	16041-10000-08371	3428 W 8TH ST	90005	10	132B193   625	5093017012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	03/18/2016 12:00:00 AM		Permit Finaled	05/04/2016 12:00:00 AM	ADDRESS	34.05754	-118.30431	T-24, TI TO AN (E) RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2291.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66484	18041-10000-28402	1 S LMU DR SUITE 4900	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	33.96577	-118.42406	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 2469 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66485	13041-10000-35391	1117 N WESTMORELAND AVE	90029	13	144B197   642	5542027036	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.09145	-118.28797	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformerless inverter: Solaredge SE 3800A-US. (18) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66486	16041-10003-12995	419 S SPRING ST	90013	14	129A211    54	5149024027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM			PC Approved	05/30/2017 12:00:00 AM	ADDRESS	34.04843	-118.24885	Changes to approved set.  Changes to switchgear layout.  Switchgear to be two sections with separate transformer.  Plan check only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66487	11041-10000-11874	1006 E 28TH ST 1-49	90011	9	118-5A209 315	5128022009	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Apartment			06/09/2011 12:00:00 AM	07/12/2011 12:00:00 AM		Permit Finaled	08/27/2012 12:00:00 AM	ADDRESS	34.01717	-118.2574	NEW FIRE ALARM SYSTEM FOR EXISTING 5-STORY APARTMENT BUILDING. USING #14AWG SOLID, UN-COATED CONDUCTORS, SUBJECT TO FIELD INSPECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66488	18041-10000-33483	2029 S CENTURY PARK EAST # N1370	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Issued	09/11/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN AN EXISTING OFFICE AREA IN SUITE # N1370. T-24 ENERGY ONLY. 4963 SQ FT.BLDG PERMIT 18016-10000-21078	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66489	15041-20002-05456	11507 W OXNARD ST UNIT-# 4 & 5	91606	2	177B169   797	2338004012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM			PC Approved	06/02/2015 12:00:00 AM	ADDRESS	34.1796	-118.38271	PC FOR POWER ONLY. ENERGY PC COMPLETED UNDER MASTER APP. THIS TENANT NO MEDICAL USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66490	15041-10000-29025	1999 S AVENUE OF THE STARS FLR 7,8	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN IN THE 7TH AND 8TH FLOORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66491	18041-10000-11642	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			03/30/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.79072	-118.29449	PLAN CEHCK FOR POWER AND ENERGY FOR - INTERIOR TENANT IMPROVEMENT OF 2,900 SF CONSIST ON CONVERT EXISTING PHARMACY CAPACITY LOCATED AT THE FIRST FLOOR INTO A GERIATRIC DEPARTMENT (MEDICA FACILITY LOCATED IN METHANE ZONE). NEW ELECTRICAL EQUIPMENT IS CONNECTED TO EXISTING PANELS. TOTAL AFFECTED AREA = 2667 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66492	12041-10000-21610	738 E 12TH ST	90021	9	123A211    36	5132012035	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			09/12/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.03297	-118.25214	Ti in an existing retail. EPC is for T24, units A & B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66493	11041-10000-16312	14227 W VANOWEN ST	91405	6	183B153  1077	2217012081	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/03/2011 12:00:00 AM		Permit Expired	08/27/2013 12:00:00 AM	ADDRESS	34.19407	-118.44291	REPLACING AN EXISTING (OLD) FIRE ALARM PANEL WITH A NEW ONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66494	15041-20000-35422	17144 W KINGSBURY ST	91344	12	207B133   624	2695006029	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.26343	-118.5071	PV1, roof mounted solar system 6kW AC.(27) modules: HANWHA Q-CELLS Q-PEAK-BLK-G3-270W(1) inverter: Solar Edge SE6000A-US (240V)(1) Power Optimizer	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66495	14041-20000-02042	11100 W SANTA MONICA BLVD 15th floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	Change to lighting in an existing high-rise office building.  Load is 250 amps per applicant  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66496	17041-10001-14936	10250 W SANTA MONICA BLVD UNIT# 1360	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	1st revision to approved set on RETAIL STORE (UNIT #1360 TIFFANY & CO.) , changes noted and clouded under delta 4. Scope inludes add new loads (receptacles); relocate some equipments due to architectural change; revise lighting fixtures and update T24 calculation	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66497	13041-10001-34522	2595 N BEACHWOOD DR	90068	4	154-5A189 271	5585007021	RD2-1XL	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.11775	-118.32178	Expedited RSES plan check per applicant request.{{PV1, Install a 1.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[POWER-ONE # AURORA PV1-3.0-OUTD-S-US] and (6) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66498	17041-10000-00286	9725 N OWENSMOUTH AVE	91311	12	201B105   164	2746016024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.24698	-118.60181	PC for energy only. Remove HID outdoor fixutres and replace with new LED fixtures. Total area:6,650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66499	15041-10012-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET UNDER DELTA 41.SCOPE INCLUDES CHANGES TO FEEDER DISTANCE AND REVISION TO ELECTRICAL ROOM EXIT SIGNS LAYOUT.PLAN CHECK ONLY!!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66500	16041-20000-29210	20756 W COMMUNITY ST	91306	3	192B109   566	2780006026	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Expired	09/28/2018 12:00:00 AM	PIN	34.22193617	-118.58598284	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (44) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66501	15041-10000-12013	5659 W 8TH ST 1st floor	90036	4	132B181  1298		[Q]R4-1	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			04/22/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Closed	08/18/2015 12:00:00 AM	ADDRESS	34.06073	-118.35299	Title 24 for (E) 5 story building. Scope of work in main lobby. Total Sq. Ft. 667	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66502	19041-10001-06227	2450 E CENTURY BLVD	90002	15	091-5A217 110	6046019923	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM			PC Info Complete	10/09/2019 12:00:00 AM	ADDRESS	33.94627	-118.22941	Changes to approved set, all changes are clouded under delta 5. Changes include relocating circuits, adding busway and revising single line, and changes to load calcultions. No changes to lighting plan. Original scope:Full plan check for 1st time tenant, New Gym (BLINK) Scope includes new lighting and equipment with a total area of 16,790 SQ FT, located in a single story commercial building with an existing 1,200 Amp Service dedicated to this tenant.Building Permit: 19016-10000-04848	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66503	16041-10000-27034	1177 E 35TH ST	90011	9	115-5A209  63	5114029026	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.01206	-118.25464	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66504	15041-20002-09718	7326 N RESEDA BLVD	91335	3	186B125   788	2119019032	[Q]C2-2D-CDO, [Q]P-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.20379	-118.53585	Changes to an approved set, relocate transformer, added panel PL. Permit issued under 15041-20001-09718***Changes to approved set.  Revised floor plan, vacuum area and toll booth added, and DWP transformer and main switchboard relocated.  All changes clouded with delta 1.********Previous work description*****Plan check for pwer and Title-24 (energy).  Total area = 2,474 sq. ft. (indoor) + 22,590 sq. ft. (outdoor)New 1000 A service and electrical distribution system for carwash.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66505	14041-20001-24866	7006 S HOOVER ST UNIT 7	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	EXPEDITE PER CUSTIOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #7.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66506	11041-20001-10765	6333 W 3RD ST #020-#P20	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM			PC Approved	03/09/2012 12:00:00 AM	ADDRESS	34.07157	-118.36014	Changes from previously approved plans.  Changes include load calculation and  lighting indicated by DELTA 4.  Plan check for power and energy.Note: Approved plans submitted for reference only.*****Plan check for power and energy. New panels, ckts and equipment. TI restaurant (place of assembly)*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66507	11041-10001-23583	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			04/25/2012 12:00:00 AM	05/15/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.01303	-118.24279	REVISED DRAEINGS SHOWING THAT THE SERVICE IS EXISTING,NEW CIRCUITS AND EXISTING DISTRIBUTION EQUIPMENT.SINGLE LINE SHOWS CLOUDING OF EQUIPMENT THAT WERE REVISED.TI IN AN EXISTING COMMERCIAL LOCATION.  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66508	12041-10000-01588	4560 W DORAN ST	90039	4	165B201    35	5593005031	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Closed	01/30/2013 12:00:00 AM	ADDRESS	34.15294	-118.27759	New 2000 Amp service & distribution board to feed a new Grinder machine. EPC is for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66509	14041-20000-32897	12137 W TIARA ST	91607	2	177B165   844	2340004036	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.17846	-118.39793	PV1 INSTALL ROOF MOUNTED PV SYSTEM SIZED 9.2 KW. STANDARD PLAN MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66510	14041-10000-07554	12920 W ADDISON ST	91423	4	171B161  1070	2358022013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.16111	-118.41446	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER STANDARD PLAN. SYSTEM SIZE:1.75 KW DC.(7) SUN EDISON MEMC M250 MODULES.(7) ENPHASE M215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66511	12041-10000-12908	3525-3535 E WHITTIER BLVD 1--78	90023	14	121-5A227 188	5188005021	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Apartment			06/18/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.02645	-118.19754	New 78-unit apartment complex with 2500A service.  Full plan check.  Variance will be filed to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66512	12041-10000-03081	603 S GAFFEY ST	90731	15	015B197   364	7451035025	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	33.73862	-118.29255	New fire alarm system for a  grocery store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66513	19041-10000-51072	1319 S SPAULDING AVE	90019	10	129B177   321	5086028010	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.05204	-118.36178	Plan check for a PV-1 system. 19 modules witha a central inverter (SOLIS-1P6K-4G-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66514	13041-20000-01801	2457 N HIDALGO AVE PV-1	90039	13	148-5A209 230	5440011026	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	04/23/2013 12:00:00 AM	ADDRESS	34.10166	-118.25651	SOLAR SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66515	10041-10003-05199	633 S MISSION ROAD	90023	14	124-5A219   3	5171015001	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/05/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	PIN	34.0373651	-118.22637397	REPLACE THE DAMAGED SERVICE EQUIPMENT DUE TO FIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66516	14041-10000-17781	1614 S HILTS AVE 1-5	90024	5	132B157   916	4326025028	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Apartment			07/01/2014 12:00:00 AM	06/27/2018 12:00:00 AM		Issued	06/27/2018 12:00:00 AM	ADDRESS	34.05549	-118.43188	plan check for power and energy. 3 typical units. BLDG#14010-10000-01997: 4-STORY (12 CONDO UNITS) BUILDING W/ 2-STORY UNDERGROUND PARKING***extension filed on 1/22/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66517	16041-10000-08795	1245 W WILSHIRE BLVD	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	PC FOR POWER AND ENERGY.  TI. FIRST TIME TENANT. MEDICAL OFFICE. TOTAL AREA 3180 SQ FT. ORIGINAL PERMIT: 100041-20003-24663	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66518	17041-10000-12969	300 E ROSE AVE	90291	11	111B141   675	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	33.99652	-118.47669	FA SYSTEM FOR 2 STORY TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66519	14041-20000-00039	11700 W LAURELWOOD DR	91604	2	162B169   703	2369030002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Expired	01/26/2016 12:00:00 AM	ADDRESS	34.13927	-118.38695	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66520	15041-10000-34664	707 W WILSHIRE BLVD ste 4100	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/01/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	T-24, tenant improvement to a high rise building. installing and relocating light fixtures. Existing service and equipment. Scope of work is being done in suite 4100. Sq ft = 4724	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66521	12041-10000-26758	6803 W MELROSE AVE	90038	5	141B181   567	5524014027	C4-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM			PC Approved	11/07/2012 12:00:00 AM	ADDRESS	34.08359	-118.34086	COMMERCIAL T24 PLAN CHECK ONLY. WITH EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66522	15041-20001-10430	1159 N SOMERA ROAD	90077	5	144B145    36	4369031030	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2016 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.09426	-118.45845	Plans lost per applicant.  Recheck and restamp of plan set.  (((Plan check for PV system ground mounted 7.28kW system with 26 modules(SunModule Plus SW280 Mono) and 1 inverter(Fronius Promo 7.6-1))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66523	14041-10000-04197	3183 W WILSHIRE BLVD 1-449	90010	10	135B197  1212	5077009916	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM			Verifications in Progress	05/14/2014 12:00:00 AM	ADDRESS	34.06196	-118.29111	T24 FOR EXISTING MIXED USE BUILDING IN THE COURTYARD AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66524	19041-10000-06914	101 N JUDGE JOHN AISO ST	90012	14	130-5A213  86	5161013905	PF-2D-CDO	Central	Central City	Los Angeles Historic Cultural		2074.00	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.05103	-118.24074	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66525	17041-20000-12204	660 S FIGUEROA ST Ste 1000	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	05/16/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	TI to (E) commercial office space in highrise building.  Plan check for energy.  Partial permit fees paid under 17041-20000-10473 for receptacle outlets.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66526	19041-20000-51175	4312 N HAYVENHURST AVE	91436	5	165B137   217	2291005020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/13/2020 12:00:00 AM		Issued	01/13/2020 12:00:00 AM	ADDRESS	34.14943	-118.49465	PV1. INSTALL 20.13 KWDC PV SYSTEM WITH (61) MODULES/OPTIMIZERS AND (2) INVERTER(7.6KW)  AND 1 INVERTER(11.4KW).FEES $0.00 DUE TO CALIFORNIA SENATE BILL 1222 AND AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66527	19041-20000-22215	7952 W 4TH ST pv1	90048	5	135B177    41	5511039020	R2-1-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.07001	-118.36325	pv1install roof mounted pv system sized 3.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66528	17041-20001-41621	12700 W VAN NUYS BLVD bldg 11,12-,13	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			11/16/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.27528	-118.4092	expeditepv2install roof mounted pv system sized 32.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66529	16041-20000-40157	9251 N WOODLEY AVE	91343	12	198B141   487	2676014025	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.23899	-118.48523	Plan check for the addition of a PV system onto an existing PV1 roof-mounted PV system. System addition size is 3 kWac for a total system size of 9 kWac. System addition consists of (1) inverter, (12) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66530	18041-10005-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	34.26056	-118.35206	PC FOR CHANGES TO APPROVED SETINSTALL ADDITIONAL ESS (2ND )  WITH NEW LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66531	19041-10000-50157	9811 N AMESTOY AVE	91325	12	201B133   258	2692014014	RA-1-H	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	02/21/2020 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.24879	-118.50692	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 24  (PANASONIC VBHN325SA) MODULES, 24  (SOLAREDGE P400) OPTIMIZERS, 1 (SE7600H-US) CENTRAL INVERTER,  CONNECTED TO AN EXISTING 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 7.80KW DC & 7.60KW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66532	18041-10000-26575	7270 WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			Ready to Issue	03/03/2020 12:00:00 AM	ADDRESS	33.94145	-118.42037	PLAN CHECH FOR 50KVA SYSTEM ROOF MOUNTED PV CONSISTING OF 1 CENTRAL INVERTER(TRIO 50.0-TLOUTD-US) WITH 10 STRINGS AT 14MODULES A TRING = 140 MODULES(SOLARWORLD SW350)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66533	18041-10001-23936	360 E 2ND ST 8TH FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Info Complete	09/27/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 8. CHANGES INCLUDE ADDING REPLACING LIGHTING FIXTURES, RELOCATING/ADDING EXIT SIGNS, ADDING RECEPTACLES, AND  REVISING TITLE 24 CALCULATIONS.THIS IS PLAN CHECK ONLY! PERMIT PAID UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66534	17041-10001-11121	10250 W SANTA MONICA BLVD #1707	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Changes to approved set noted as Delta 6 due to design changes. [ ""ABERCROMBIE & FITCH""  Ste.# 1707]"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66535	16041-10002-04906	966 N MORAGA DR	90049	5	141B145   234	4368019015	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.08188	-118.46728	04/04/16Changes to an approved set of plans. All changes are made under delta 1. Changes include relocating pv modules on the roof-layout. NOTE: Permit pulled PCIS#16041-10000-04906(((Permit fees are $0 due to senate bill 1222.((((PV1, rooftop solar installation 14kW system. Interconnect with 600A MS.(48) SPR-327NE-WHT-D(2) SMA 7000US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66536	17041-20001-21308	5950 N LAUREL CANYON BLVD	91607	2	177B165   769	2340005037	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.17861	-118.39631	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66537	10041-10000-03815	12100 W WILSHIRE BLVD	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM			PC Info Complete	03/15/2010 12:00:00 AM	ADDRESS	34.0438	-118.46755	T.I. for high rise building.  Install general and emergency lights in elavator lobby (levels 6th, 10t, and 11th).  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66538	11041-10001-20629	1040-1044 S DOREEN PL BLDG 4	90291	11	111B149   684	4243002068	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/11/2012 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99976	-118.45891	REPAIRS & HISTORICAL REHABILITATION  / TI OF 9 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.(((((((((((((((((((((((((((((  addition of 5 ckts for dettached garage, changes to previously approved plans))))))))))))))))))))))))))))))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66539	12041-10000-01948	24229 W HATTERAS ST	91367	3	174B089   104	2046004010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Expired	02/19/2014 12:00:00 AM	ADDRESS	34.17573	-118.6532	Plan check for 7.755KW roof mounted photovoltaic system. single family dwelling. Permit for PV installation and includes upgrading panel 125A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66540	13041-10000-15829	2121 S AVENUE OF THE STARS SUITE 1600-SUITE 1670	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.05554	-118.41342	Highrise office TI, suites 1600 and 1670.  Furniture systems installed, floor panel upgrade, new lighting.  Newly connected load < 400 A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66541	18041-10000-47200	1186 E MONTECITO DR	90031	1	144A227   482	5304010018	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.08765	-118.19961	PV1, INSTALLING 8.165 KWDC SYSTEM WITH (23) MODULES , (2) AC INVERTER WITH 7.6 KW, (1) 3 KW,  (1) POWER OPTIMIZER P400.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66542	17041-10000-08425	20822 W DEARBORN ST	91311	12	198B109   157	2748037024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Issued	03/16/2017 12:00:00 AM	ADDRESS	34.23712	-118.58724	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 10,404 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66543	14041-10000-03955	14622 W VENTURA BLVD	91403	4	166-5A151 118	2276002066	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.15125	-118.45177	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR STARBUCKS. 855 SQFT. EMERGENCY LIGHTING EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66544	14041-20001-30857	7880 N VAN NUYS BLVD	91402	6	189B149   638	2212028014	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM			PC Info Complete	04/28/2016 12:00:00 AM	ADDRESS	34.21541	-118.4462	04/28/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the electrical service distribution equipment and existing panels have been re-fed. *****Previous Work Description*****Complete gut and rebuild. new service, new equipment, new lighting. This is a vanilla shell. 800A service. PC for power and energy. TI will be submitted by tenant at another time. zoned for retail use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66545	16041-20006-44615	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM			PC Approved	11/01/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED DELTA 21 CHANGES ONLY, ADDITION OF 4 EXIT SIGNS, 4 SCONES, 2 1X4 LIGHTS, AND REMOVAL OF ONE LIGHT ON BASEMENT FLOOR PLAN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66546	15041-10000-24151	11382 N BORDEN AVE	91331	7	213B161   916	2532007014	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2015 12:00:00 AM	09/24/2015 12:00:00 AM		Permit Finaled	01/05/2016 12:00:00 AM	ADDRESS	34.27702	-118.4092	PV 1 INSTALL 7.39 KW DC MOUNTED MICROINVERTER SOLAR SYSTEM. SINGLE FAMILY HOME. (29) MODULES TRIINA SOLAR 255 W (29) MICROINVERTER:ENPHASE  M215-60-2LL-S22-IG	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66547	14041-10001-03348	823 S MARIPOSA AVE	90005	10	132B197   604	5094018013	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	34.05705	-118.2989	(((4/14/2014- CHANGES MADE TO APPROVED SET. SERVICE SIZE CHANGED TO 400A)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING ROOF MOUNTED SYSTEM. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66548	09041-20002-23939	6141 W FRANKLIN AVE	90068	4	150A189   174	5586007025	R3-1	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM			PC Approved	07/14/2011 12:00:00 AM	PIN	34.10539772	-118.32367026	Plan check power only. Existing service supplying new panel and water heater. Existing building with multiple services. T24 Energy under previous plan check. Existing permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66549	15041-20000-23565	718 N AVENUE 64	90042	14	156A233   381	5716010015	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.12028	-118.1779	Plan check for a PV1 roof-mounted PV system. System size is 3.2 kWac and consists of (15) modules and (15) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66550	10041-10000-04299	880 W 1ST ST	90012	9	132A211    23	5151016***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Apartment			03/10/2010 12:00:00 AM	03/10/2010 12:00:00 AM		Permit Expired	08/22/2012 12:00:00 AM	ADDRESS	34.05728	-118.25174	Installing one panel and 17 devices for elevator supervisory. 8 story high.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66551	14041-10000-17260	5340 S ALLA ROAD # 105	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	33.9773	-118.42567	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY (CLUB W). NEWLY CONNECTED LOAD < 400 AMPS. 5225 SQFT, EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66552	15041-20000-01884	10960 W WILSHIRE BLVD 23 & 24	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			Reviewed by Supervisor	03/02/2015 12:00:00 AM	ADDRESS	34.058	-118.44597	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. NEWLY CONNECTED LOAD < 400 AMPS. 44,000 SQFT. OFFICES . LEVEL 23 &24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66553	16041-20000-00523	3415 S SEPULVEDA BLVD 9th Floor	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Issued	02/23/2016 12:00:00 AM	ADDRESS	34.02055	-118.42347	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to the 9th floor. Total lighting area = 13,241 sq. ft.Note: Building application has been submitted under 16016-70000-00198	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66554	15041-20000-38558	19737 W MALDEN ST	91306	3	192B117   169	2782018022	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Expired	12/19/2017 12:00:00 AM	ADDRESS	34.22553	-118.56361	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (24)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB# PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66555	16041-20000-07560	541 S SPRING ST 124-126	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.04657	-118.2507	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,126 sq. ft.Note: Building application has been created under 16016-10000-02123	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66556	19041-20000-39407	19476 W PAUMA VALLEY DR	91326	12	213B117   313	2822027001	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.27929	-118.55629	PV1. INSTALL 10.54 KW DC PV SYSTEM WITH (31) MODULES/MICROINVERTERS (ENPHASEIQ7PLUS-72-2-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66557	16041-20000-41309	1717 E 7TH ST	90021	14	124-5A215  56	5164022003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.03495	-118.23573	Tenant improvement of (E) 1-story office and warehouse space wtih mezzanine.  No change of use. Plan check for power and energy; over 400A of newly connected load.  (E) 600A 120/240V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66558	18041-20000-44077	7619 N WILBUR AVE	91335	3	186B121   136	2104013026	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Permit Closed	11/14/2023 12:00:00 AM	ADDRESS	34.20894	-118.54502	pv1install roofmounted pv system sized 9KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66559	12041-10000-07179	410 N BARRINGTON AVE	90049	11	138B141  1110	4429021054	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2012 12:00:00 AM			Reviewed by Supervisor	10/23/2012 12:00:00 AM	ADDRESS	34.06949	-118.47343	New 9,000 sq. ft Single family residence with accessory structure, pool, and tennis court.  New 800A service.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66560	18041-10000-36444	13320 W VENTURA BLVD	91423	4	165B157   895	2373001018	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1439.02	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.14652	-118.42319	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66561	18041-10000-48439	2423 E CESAR E CHAVEZ AVE	90033	14	129A225   289	5177034018	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.04659	-118.20694	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66562	17041-10000-39467	127 S SAN VICENTE BLVD 7TH FLR	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.07457	-118.37864	PC for power and energy for 7th floor TI for medical office (OSHPD 3) at Cendars-Sinai. TI  on 7th floor cancer treatment medical offices and exam rooms. Installing seven new panels, lights, receptacles and equipment. Total area 41332sqft. Building# 17016-10000-32429.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66563	19041-20002-01327	7643 N SHADYGLADE AVE	91605	2	186B165    86	2307005020	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	34.20994	-118.40267	3/4/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta E. Location of Inverter has changed from South to North wall.02/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta C and D. Inverter model has changed. Inverter now being used integrated EV charger.*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 9.57 kWdc/8.79 kWac-CEC and consists of (1) 7.6 kWac rated inverter and (29) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66564	18041-20000-33675	5264 N CALATRANA DR	91364	3	171B105   458	2168017060	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.16528	-118.60343	Plan check for a PV1 roof-mounted PV system. System size is 13.65 kWdc/11.4 kWac and consists of (1) inverter and (42) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66565	18041-10000-01504	7125 N SOPHIA AVE	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.2002	-118.48712	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 12625 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66566	19041-10001-22974	3418 N BLAIR DR	90068	4	159B181    84	5579010013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	Yes	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.13463	-118.34567	"DELTA ""1"" CHANGES TO APPROVED PLANS. REMOVING THE ""ENPHASE IQ COMBINER"" PANEL ON PAGE 2. PLAN CHECK ONLY. PERMIT# : 19041-10000-22974<<<PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15  MODULES (PHONO SOLAR PS325M-24 AND 15 MICROINVERTERS (IQ7-60). SYSTEM SIZE IS 4.875KWdc AND 3.75KWac>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66567	18041-20001-25855	19519 W ROSCOE BLVD	91324	12	192B117   729	2783009009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	ADDRESS	34.22064	-118.5584	"Revisions to approved set of plans.  Revised submetering details to comply with disaggregation requirements.  EV charger detail changes.  Miscellaneous revisions.  Approval for clouded revisions onl sheets ES101, E-601, and EP101 only. (((Plan check for power and energy for ""A"" Occupancy. New Church/house of Worship Building. Total indoor and outdoor area: 24,512 sq ft. 400A ServiceB#16014-20000-06238)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66568	18041-30000-15411	2029 S CENTURY PARK EAST 41st Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site are the corridors on the 41st floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 3,110 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66569	18041-20001-44700	449 N OGDEN DR	90036	5	141B177  1256	5527029031	RD1.5-1-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.07956	-118.35954	04-16-2019 Changes to an approved set of plans, changes include addition of sub-panel for microinverters and remove performance meter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66570	19041-10000-25466	1115 W SUNSET BLVD	90012	1	136-5A211 439	5406020002	C2-2D	Central	Central City North	Historic Cultural North	YES	1977.00	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	06/24/2020 12:00:00 AM	ADDRESS	34.06687	-118.24925	INSTALLING 43 NEW EV CHARGERS (40 @ LEVEL 2 & 3 @ LEVEL 3) IN A HIGH RISE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66571	19041-10000-46826	1423 S MANHATTAN PL	90019	10	129B193  1546	5073008007	R2-1-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Issued	11/14/2019 12:00:00 AM	ADDRESS	34.04563	-118.31036	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66572	10041-10000-20165	1425 N SAN PABLO ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM	05/20/2011 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.06176	-118.20365	AT THE BASEMENT LEVEL, TENANT INPROVEMENT  AND CONSTRUCTION OF A TUNNEL TO AN ADJACENT BUILDING  REF.#10044-10000-09929.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66573	16041-10000-45089	12100 W SHELDON ST	91352	6	198B165   234	2631002900	(Q)R3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Apartment			12/23/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.23724	-118.3962	PC for energy only. Outdoor title 24. Remove HID fixture and replace with new LED fixtures. Area: 8,500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66574	13041-10000-02833	18326 W SAN JOSE ST	91326	12	207B125   574	2731013042	RE11-1	North Valley	Northridge	Northridge East		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM	02/04/2013 12:00:00 AM		Permit Finaled	03/18/2013 12:00:00 AM	ADDRESS	34.26068	-118.53287	photovoltaic system for single family single story DWELLING. TOTAL SYSTEM SIZE OF 8.64 KW. USING 36 PANELS. SOLAR PANEL TRINA SOLAR TSM 240PA05. CENTRAL INVERTER SUNNY BOY 7000-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66575	13041-20000-10197	12411 W SHELDON ST #2	91352	6	195B165   204	2629019015	(T)(Q)C1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.23261	-118.40328	First time tenant in space #2.  Full plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66576	18041-10000-02329	3411 N MANDEVILLE CANYON ROAD	90049	11	150B133    65	4491006006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM			Reviewed by Supervisor	01/30/2018 12:00:00 AM	ADDRESS	34.10623	-118.50288	PV 1, Roof Mounted solar system to a single family dwelling with AC energy storage batteries. (1) 7.6KWAC inverter, (29) modules, (2) AC tesla batteries and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66577	15041-20000-29715	12648 N OLAF PL	91344	12	219B129    40	2608029037	RE11-1-H, RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.30079	-118.51782	Installation of new roof mounted solar PV array.  Total system size = 12.5 kWac.  Microinverter system with 50 Enphase M250 arranged in 4 branch  circuits..	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66578	11041-20000-08142	21800 W OXNARD ST	91367	3	177B105    81	2146006046	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	ADDRESS	34.17898	-118.60253	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66579	19041-20000-52571	7230 W FRANKLIN AVE	90046	4	147B181    29	5548001021	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	02/11/2020 12:00:00 AM		Issued	02/11/2020 12:00:00 AM	ADDRESS	34.10328	-118.3468	Installation of (25) EV chargers with load management system.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66580	14041-20000-24887	7014 S HOOVER ST UNIT 5	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 5.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66581	12041-10000-11959	452 S MAIN ST	90013	14	129A211   150	5148009015	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			PC Info Complete	07/30/2012 12:00:00 AM	ADDRESS	34.04697	-118.24801	First time tenant. Restaurant. Plan check for power and energy. 1920 sqft. Low rise commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66582	19041-20000-43302	11642 N GOTHIC AVE	91344	12	213B137   263	2605017037	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	PIN	34.28204741	-118.4886719	PV1.  Install 3.2 kW DC / 2.75 kW AC roof mounted grid tied PV system.  (10) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66583	15041-10000-29654	4440 N SEPULVEDA BLVD	91403	5	166-5A145  94	2276041054	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	34.15101	-118.46711	Power plan check for feeder upgrade to all panel with (2) 2500-Amp existing servicex located in a 3-story 104-units apartment building with 2-level under ground parking.INSTALLINF 2 EA CIRCUITS IN EACH OF THE 104 UNITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66584	12041-20000-01907	6845 N VINELAND AVE Bldg B	91605	2	183B173   213	2319005022	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Expired	02/19/2014 12:00:00 AM	ADDRESS	34.19522	-118.37051	The plan shows a auto repair facilty associated with an auto sales office.  The auto sales office is new and will be permited on a separate application.  The repair facility is a remodeled mfg building.  Checked for T24 lighting compliance and electrical power, and hazardous location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66585	14041-20000-09129	555 W 5TH ST FLOORS 24-27	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.05016	-118.25369	NON-STRUCTURAL INTERIOR OFFICE T.I. TO FULL 4 FLRS (24TH FLR THRU 27TH) 24,170 S.F. EACH FLR. NO CHANGE OF USE.  ADDITION OF UPS AND 5 NEW PANELBOARDS.   FIRE ALARM PLANS INCLUDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66586	19041-20000-24210	13236 W CANTARA ST pv1	91605	2	192B157  1030	2304008052	(T)RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.21969	-118.42129	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 30 MODULES (LG 335) WITH INPHASE IQ7 MICRO INVERTERS. SYSTEM SIZE IS 10.05KWdc AND 7.5 KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66587	19041-10000-14088	6505 N RESEDA BLVD	91335	3	180B125   488	2127011028	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.18853	-118.53623	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66588	14041-20000-29636	707 N NORTH FARING ROAD	90077	5	144B153   762	4358001009	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.0897	-118.43504	Upgrade service to 600A.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66589	16041-20000-21003	3330 N CAHUENGA BLVD WEST SUITE 501	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.13099	-118.35061	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. ACTIVE VIDEO .SUITE 501.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66590	17041-20002-42261	10205 N TELFAIR AVE	91331	7	204B161   330	2623011001	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.25561	-118.41738	12.6.2017 - Plan check for modifications to approved set. Rearrange equipment along south east wall (see cloud on sheet 2 marked delta C). Only change.=====PV1. Install roof mounted PV system sized 10.4 kW intetrconnected with MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66591	16041-10000-32900	1200 S BROADWAY	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			09/15/2016 12:00:00 AM			PC Approved	10/05/2016 12:00:00 AM	ADDRESS	34.03792	-118.26026	Changes to approved set of plans noted under Delta-14. Revise demand load due to laundry combo washer/Dryer , updated feeders, volt. drop, and panel schedules.*This is plan check only, permit shall be under 15041-10000-14886	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66592	08041-10002-14552	2142 S PONTIUS AVE	90025	5	126B153   755	4322025041	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM			PC Approved	01/25/2012 12:00:00 AM	ADDRESS	34.04026	-118.43869	Modification to approved drawings to change auto-shut-off for parking garage from timeclock to oc. sensor.((((Electrical installation for new 3-story office building + 2 subterranean parking garages. New 120/208V 3ph 4W 2000A Service. EPC: Power and Energy(T-24).))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66593	16041-20003-09548	16901 W NAPA ST	91343	12	195B133   508	2689018032	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.22679	-118.50046	4/16/2018CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2 AND 3.  THIS IS PLAN CHECK ONLY.   (((PV2. ROOFMOUNTED SOLAR SYSTEM.  TOTAL SYSTEM SIZE: 364 KW.   TWO BUILDING CONNECTED AS ONE FEED IN TARRIF SYSTEM.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66594	14041-10000-08643	10673 SATICOY ST	0	2									Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			Reviewed by Supervisor	05/16/2014 12:00:00 AM				PV1, INSTALL 4.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(19) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66595	14041-20000-01412	1734 S BARRY AVE 1-8	90025	11	126B149   648	4262019016	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	01/15/2015 12:00:00 AM	ADDRESS	34.04122	-118.45223	PV2 APARTMENT COMMON METER. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66596	19041-20000-34339	5373 N LANKERSHIM BLVD	91601	2	171B173    90	2350012920	PF-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	05/21/2020 12:00:00 AM	ADDRESS	34.16858	-118.37715	Plan check for proposed EV bus chargers at Metro bus stop.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66597	13041-20000-29994	821 N STRADELLA ROAD	90077	5	141B149   114	4369023011	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Expired	11/19/2015 12:00:00 AM	ADDRESS	34.08375	-118.45353	pv1 single family dwelling. total system size 6.4 kw ac using 30 modules. using enphase microinverter. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66598	17041-20000-24250	10829 W OXNARD ST	91606	2	177B173  1012	2414005010	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.17956	-118.36735	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTAURANT. 1140 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66599	15041-10000-03356	500 WORLD WAY T05	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	33.94248	-118.40461	Plan check for Title 24 only. Project space is retail. Space is located in Terminal 5 (Space 5U). Total lighting area = 160 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66600	14041-20001-07178	17745 W SIDWELL ST	91344	12	219B129   657	2601071009	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.30083	-118.52096	Change from previously approved plans.  Change in down sizing from 8.25KW to 6.5KW.Note: Permit is under the original application.  Plan check fee is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****New PV central X-formerless INV for a single family. 8.25 kw system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66601	18041-10000-12411	7358 N DEERING AVE	91303	3	186B105   633	2112025001	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	02/13/2020 12:00:00 AM	ADDRESS	34.20453	-118.59653	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66602	13041-10000-22532	5735 N OSTROM AVE	91316	5	174B133   253	2255017007	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.1752	-118.50685	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A STANDARD PLAN (NEGATIVELY GROUNDED). SYSTEM SIZE IS 12.74 KW DC AND 10 KW AC. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: FRONIUS # IG PLUS V 10.0]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66603	15041-10000-06267	11500 W OLYMPIC BLVD	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM			PC Info Complete	04/16/2015 12:00:00 AM	ADDRESS	34.03624	-118.44415	Energy plan check for an office T.I located in the 3rd floor of a high rise building. Total area is 13,183-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66604	12041-10000-24930	7842 W VERAGUA DR	90293	11	099B153   129	4114006022	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	12/11/2012 12:00:00 AM	ADDRESS	33.96384	-118.43511	New 5.46 kw roof mounted PV system for a single family. PV1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66605	18041-20000-47002												Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66606	19041-20003-06863	8700 S PERSHING DR PV5	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Revisions to approved set of plans and change of scope of work.  Approval for clouded changes delta-1 only.  Work description change: PV2.  Install 113.15 kW DC / 103.39 kW AC roof mounted grid tied PV system.  (310) modules with (3) 33.3 kW rated inverters.  Interconnecting with MSA-5.  (((PV2.  Install 71.18 kW DC / 65.04 kW AC roof mounted grid tied PV system.  (195) modules with (2) 33.3 kW rated string inverter.  Interconnecting with MSA-5.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66607	14041-10001-20847	165 S MISSION ROAD	90033	14	129A217   171	5172013004	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM			PC Approved	09/09/2014 12:00:00 AM	ADDRESS	34.04593	-118.22811	Title 24 plan check only.  Total area = 7000 sq. ft. unconditioned and 2,596 sq. ft. conditionedReplacing existing lighting fixtures with new flourescents.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66608	14041-20002-03334	21001 W SHERMAN WAY	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			PC Approved	09/25/2014 12:00:00 AM	ADDRESS	34.20126	-118.59094	revision to an approved set of plans.  change from 400 amp bus to 400 amp wire, to be UL listed. Plan check for 'Planned Parenthood' medical facility, consisting of patient care area (multiple exam rooms for medical and clinical care) . Projected area in lighting scope of work is approx. 2218 sf, with emergency lighting. Not an OSHPD facilitiy per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66609	13041-10000-08007	1300 W 177TH ST E	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	33.87031	-118.29542	T24 FOR COMMUNITY USE BUILDING. 2786 SQRFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66610	08041-10001-07630	3201 S LA CIENEGA BLVD Bldg 1.21/-1.22	90016	10	123B173  1531	4205035010	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	04/20/2012 12:00:00 AM	ADDRESS	34.02965	-118.37211	Delta 3 modifications to prevously approved set of plans.  Rename panel from A120 to A3137and add one new panel named C3137, see single line diagram.  Transfer circuits from panel A3201 to new panel C3137.  No net increse in service load. Change does not affect T24 or Load calculations for the service equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66611	11041-20000-09151	11277 W DORA ST	91352	6	192B173   472	2632005013	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Expired	08/08/2013 12:00:00 AM	ADDRESS	34.22184	-118.37738	New commercial building with 800 amp main switchboard.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66612	14041-20000-11233	127 S SAN VICENTE BLVD lvl 8,9	90048	2	180B161  1049	2325032004	[Q]C1-1VL, [T][Q]C2-2D-O	Central	North Hollywood - Valley Village, Wilshire	Greater Valley Glen, Mid City West		1237.00	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.07457	-118.37864	plan check for power. add circuits to freezer for labortory area at Cedars-sinai medical center. none surgical area according to applicant. partial level 8th and 9th.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66613	19041-10000-09981	4737 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			03/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.04689	-118.34019	Energy plan check for a change of use from retail to restaurnat TI. Scope includes new lighting and equipment with a total area of 2300-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66614	14041-20000-22952	4700 W MARWOOD DR	90041	14	160-5A219 306	5684031018	RE20-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	PIN	34.13245125	-118.22344257	PV1.  Install 2.50 kW roof-mounted, utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66615	15041-10000-29073	7435 N VALJEAN AVE TENANT A	91406	6	186B137    26	2205010901	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.20582	-118.48615	FULL PC FOR FIRST TIME TENANT FOR A 2-SOTRY COMMERCIAL OFFICE BUILDING TO THE VAN NUYS AIRPORT. TOTAL AREA IS 4471 SQ. FT. CORE AND SHELL APPLICATION REFERENCE #15041-10000-16156.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66616	17041-10000-11212	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.0631	-118.36086	PC for new fire alarm system for a 5 story academy museum with 3 lower levels. Total of 20 FA panels and 1240 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66617	10041-10000-14707	1418 S BUTLER AVE Bldg 6	90025	11	129B149   200	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Corrections Issued	09/24/2010 12:00:00 AM	ADDRESS	34.04803	-118.4539	NEW SERVICE , PANELBOARDS AND CIRCUITS FOR 18 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66618	15041-20000-14813	5161 W SUNSET BLVD 1-6	90027	13	147A195    97	5544015038	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Apartment			05/14/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.09828	-118.30266	Installation of new fire alarm system in existing 6 unit apartment building.  9 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66619	18041-30001-34907	5503 E BALTIMORE ST	90042	1	154-5A227 196	5478009076	R2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM			PC Approved	03/07/2019 12:00:00 AM	ADDRESS	34.11765	-118.19793	03/07/2019 Plan check for a lost set of plans. Scope of work and system characteristics have remained the same.*****Original Scope of Work*****NEW ROOF MOUNTED 5.61 kWdc/5.15 kWac-CEC PV SYSTEM WITH 19 PV PANELS AND 1 INVERTER ON A SINGLE FAMILY HOME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66620	19041-10000-15791	1500 W 6TH ST	90017	1	132A205   142	5142028020	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.05643	-118.26833	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66621	19041-10000-41160	3200 W TEMPLE ST	90026	13	139-5A201 262	5156006003	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Closed	06/22/2023 12:00:00 AM	ADDRESS	34.07517	-118.28141	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS INDOOR AND REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES OUTDOOR- T/24 ONLY (INDOOR & OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66622	19041-20000-18678	1677 N LUCILE AVE	90026	13	145-5A203 252	5429014009	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.09303	-118.27762	Plan check for a PV1 roof-mounted PV system. System size is 7.32 kWdc/7.6 kWac and consists of (1) inverter, (24) modules, (1) load center, and (1) battery back-up unit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66623	15041-20002-14731	6250 N TOPANGA CANYON BLVD F Ste 1580	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM			PC Approved	11/10/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	10/19/15: Supplemental2: changel of lighting fixtures, T24 readjust.Plan check for 1st time tenant. Interior T.I. of retail store[VARGAS] within an existing shopping center to include new accessible employee restroom, new changing rooms and new storage room. Total area:1880 sq ft. SUITE 1580	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66624	13041-10000-32040	7565 W BEVERLY BLVD	90036	5	138B177   410	5526041014	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM			PC Info Complete	11/19/2013 12:00:00 AM	ADDRESS	34.0763	-118.35487	PLAN CHECK FOR T24 ENERGY ONLY. 1 STORY BUILDING. COMMERCIAL. PERMIT PREVIOUSLY PULLED UNDER 13041-10000-31667. 950 SQFT, EMERGENCY lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66625	15041-20000-30764	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.18686	-118.37207	Plan check for energy and power in existing space TARGET interior remodel: change out lighting fixtures. Total area: 99,870 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66626	16041-20000-13350	16901 W VENTURA BLVD A-B	91316	5	168B133   104	2258018018	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.15955	-118.50149	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,405 sq. ft.Note: Building application has been created under 16016-10000-02722	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66627	14041-10000-35774	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.06338	-118.20434	Plan check for power and energy for HSC Cooling Tower relocation with existing service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66628	13041-20000-12185	4419 N AZALIA DR	91356	3	165B121   119	2177014011	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.15146	-118.54044	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.5KW. USING MICROINVERTER ENPHASE M215. NONSTANDARD PLAN. BACK ROOM PLAN CHECK. USING  26 MODULES. ALSO INCLUDES UPGRADE OF MAIN SERVICE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66629	19041-20001-00558	2307 W STRATFORD CIR	90049	5	150B141    24	4377044012	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Expired	09/23/2023 12:00:00 AM	PIN	34.11133636	-118.47818733	01-08-2019 Changes to an approved set of plan. Changes include change PV Modules manufacturer type to LG 330N1C-A5 and down size inverter to 10.0kW, New system size: 15.2kW DC, 10.0kW AC with 46 Modules Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66630	17041-10000-36301	3411 S CRENSHAW BLVD	90016	10	120B185   905	5046001021	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Public Safety Only			10/10/2017 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.02516	-118.33536	PC FOR A NEW FIRE WARNING SYSTEM  IN AN APARTMENT BUILDING. SCOPE INCLUDES 256 FA DEVICES, AND 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66631	10041-10000-16417	2440 S SEPULVEDA BLVD	90064	5	123B153   135	4256008***	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM			PC Info Complete	08/20/2010 12:00:00 AM	ADDRESS	34.03617	-118.43421	TI in an existing office area. Plan Check is for T-24 Energy Calcs and Emergency lights.  Permit is for a new 75KVA transformer, 3 panels & new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66632	18041-10003-32582	5858 W ABERNATHY DR	90045	11	099B169   101	4105006013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2019 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	33.97081	-118.38396	PC FOR CHANGES TO AN APPROVED PV SYSTEM. DELTA 2 CHANGES ONLY WHICH INCLUDES ADDING NEW AC DISCONNECTS AND RELOCATING THE LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66633	12041-10001-16837	23504 W BALTAR ST	91304	12	189B093   211	2020017034	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM			PC Approved	08/21/2012 12:00:00 AM	ADDRESS	34.21588	-118.63894	install roof mounted solar for an existing single-family residence.  PLAN CHECK ONLY.  Permit is under the main application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66634	13041-10000-32308	6347 W WEIDLAKE DR	90068	4	153A187    13	5577034005	R1-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.11551	-118.32714	PV1, Install 7.42 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformerless inverter. Solaredge SE6000A-US. 28 modules Suniva OPT2650-60-4-1B0..	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66635	15041-10000-10701	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.94955	-118.38214	new wiring for MCCs, PC for power. .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66636	15041-10000-25844	9217 S AIRPORT BLVD	90045	11	093B169    89	4124009920	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	33.95197	-118.38615	"P.C. for T-24 only. Scope of work: Outdoor lighting for AVIS at LAWA.Total area: 1882 sq.ft.Two existing Service: (a) 800A with 1 new panel ""RB1"" 100A (b) 1000A with new panel ""G"" 200 A, and new Xformer 480 APC per applicant Request."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66637	17041-10000-16285	4260 N WHISPERING PINES CT	91316	5	165B125   251	2184040038	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.14793	-118.5286	PV1 ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER SOLAR EDGE 7.6KWAC AND (29) MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66638	15041-20000-33911	16890 W ENCINO HILLS DR	91436	5	162B133   271	2287016067	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/28/2015 12:00:00 AM		Issued	10/28/2015 12:00:00 AM	ADDRESS	34.13759	-118.50105	PV1, roof mounted solar panel 14.31 kW DC, (54) modules: Q.PRO BFR-G3 265, (2) Inverters: SB6000TL-US, (2) combiner boxesNote: Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66639	19041-10000-34357	21627 W SHERMAN WAY	91303	3	183B105   109	2111019002	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.20119	-118.60117	TI IN AN EXISTING COMMERCIAL SPACE. INSTALLING NEW LIGHTS.  T-24 ENERGY ONLY.BULDING PERMIT: 19016-20000-24506	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66640	18041-20000-07606	5839 N CRANER AVE	91601	2	174B173   157	2415002016	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.17695	-118.36938	Plan check for a PV1 roof-mounted PV system. System size is 13.1 kWac and consists of (57) modules, (57) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66641	18041-20000-23612	10073 W MCBROOM ST	91040	7	207B181    55	2543008012	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.26391	-118.35048	Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWac and consists of (42) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66642	19041-20000-53127	1240 N NORMAN PL	90049	11	141B141    93	4429038014	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.0835	-118.47893	PV1. INSTALL 10.56 KW DC ROOFMOUNTED PV SYSTEM WITH (32) MODULS AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66643	14041-20001-06915	813 N WILCOX AVE	90038	4	141B185   209	5533026058	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.08565	-118.3311	((expedite fees)))pv2 apartment rooftop solar. total system size 22.8kw ac using 2 central inverters. nonstandard plan. connect to 3 phase delta.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66644	11041-20000-16275	12251 W FOOTHILL BLVD	91342	7	213B165   158	2531003014	[Q]M1-1	North Valley	Arleta - Pacoima	Foothill Trails District	YES	1042.02	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/09/2011 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	ADDRESS	34.28229	-118.40305	PLAN CHECK T24 ENERGY FOR FOOD MANUFACTURING SPACE TENANT IMPROVEMENT. PERMIT FOR NEW CKTS, EQUIPMENT, AND WORK ON EXISTING CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66645	13041-10000-04283	380 W WORLD WAY Space T21	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	04/01/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Tenant improvement for retail shop. Submittal per customer request. Space T21	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66646	15041-10001-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 17  (CHANGES ARE CLOUDED  ON THE PLANS) REVISIONS TO PERMITTED SET OF PLANS.PLAN CHECK ONLY. CHANGES ARE MINOR AND DO NOT INCLUDE NEW LOADS AND NEW EQUIPMENT((((((((((  REPLACING DISTRIBUTION BOARDS AND PANEL BOARDS AS PART OF SWITCHGEAR UPGRADE AT TERMINAL 7; SERVICE REMAINED THE SAME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66647	16041-20000-38463	7860 N SIMPSON AVE	91605	6	189B169   517	2310025034	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.21334	-118.38872	Plan check for fire alarm only. New fire alarm system for New 4-story apartment building and subterranean parking. Note: below grade parking is shared between apartment and a New 2-story commercial building. The 2-story commercial building is N.I.C. 386 devices. New FACP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66648	12041-10000-05668	1340 S FIGUEROA ST	90015	9	126A205    86	5134010016	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			03/28/2012 12:00:00 AM	08/13/2012 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.03951	-118.26852	NEW MIXED USE 171 UNIT APARTMENT COMPLEX, 7 STORIES WITH SUBTERRANEAN PARKING. PLAN CHECK POWER AND ENERGY. TWO SERVICES SUPPLYING BUILDING. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66649	15041-20000-02380	1913 S LIVONIA AVE	90034	5	126B169   199	4302008019	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.04437	-118.38748	Roof mounted PV system with microinverter (enphase model M215-60-2LL).  Total system size 7KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66650	15041-10000-03091	11950 N PHILLIPPI AVE	91340	7	216B161   274	2514014036	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.28764	-118.41697	Installation of roof mounted solar PV array.  Total system size = 4.2 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66651	16041-10000-23099	950 S BERENDO ST	90006	10	132B197  1176	5078008023	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Apartment			06/30/2016 12:00:00 AM			PC Info Complete	01/10/2017 12:00:00 AM	ADDRESS	34.05416	-118.29358	Plan check for power and TItle-24.NEW 44 UNITS APARTMENT WITH 4 STORY OVER 2 LEVELS OF BASEMENT PARKING GARAGE.   New 2,000 A service.  11 typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66652	18041-10000-40591	26640 S WESTERN AVE STE N	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	03/19/2019 12:00:00 AM	ADDRESS	33.78015	-118.30862	PC FOR T-24 ENERGY ONLY FOR  CHANGE OF USE FROM OPTOMETRIST TO RESTAURANT (CAFE), NEW EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA  1550 SF.B#18016-40000-11690	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66653	17041-20000-36962	10100 W SANTA MONICA BLVD Ste 1060	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	Tenant improvement of (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66654	18041-10003-41854	341 N VAN NESS AVE	90004	4	138B189   219	5522027018	R1R3-RG	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM			PC Approved	01/03/2019 12:00:00 AM	ADDRESS	34.07738	-118.31586	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, REMOVAL OF 5 PV PANELS, DELTA B CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66655	17041-10000-08647	7114 W VALMONT ST	91042	7	204B201  1110	2568006032	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.25219	-118.28647	Plan check for PV roof mounted system. System size: 5.0kW with 18 modules and 1 inverter(5.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66656	17041-20000-11655	7610 N RESEDA BLVD	91335	12	186B125   123	2119001041	[Q]C2-1VL-CDO, [Q]P-1VL-CDO, [Q]R3-1-CDO	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.20889	-118.53584	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT . Change of use from retail to a restaurant.  1393 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66657	19041-20001-48215	14367 W HERRON ST	91342	7	219B149   420	2507021012	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM			PC Approved	12/13/2019 12:00:00 AM	ADDRESS	34.29746	-118.44656	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. RELOCATION OF EQUIPMENT AND REMOVAL OF AC DISCONNECTS ON SITE PLAN, ELEVATION DRAWING, SINGLE LINE DIAGRAM, AND SITE PLACARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66658	16041-10000-14602	18777 W EDLEEN DR	91356	3	168B121   223	2176026016	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.15691	-118.54114	PV1 SYSTEM, GROUND MOUNT 10KW DC, CONNECTED TO SINGLE FAMILY DWELLING. 42MODULES.(42)HANWHA Q-CELLS Q.PRO-G3G3 250(1)INVERTER-SMA AMERICA SB 9000TL-US-12-240V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66659	14041-20000-04056	11304 W SANTA MONICA BLVD	90025	11	129B149   505	4261009029	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	ADDRESS	34.04625	-118.44864	PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED UNDER THIS APPLICATION. NEW LIGHTING IN RETAIL SPACE. CIRCUIT ISSUED FOR 1 LIGHTING CIRCUIT ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66660	16041-20000-12294	601 W 5TH ST 11th Floor	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.05049	-118.25386	Plan check for Title 24 only. Project site is the elevator lobby, corridors, and restrooms of the 11th floor within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,022 sq. ft.Note: Building permit has been pulled under 16016-10000-05265	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66661	11041-20000-06742	11623 W SHELDON ST	91352	6	201B169   103	2537023015	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM			PC Approved	04/11/2011 12:00:00 AM	ADDRESS	34.24567	-118.38533	Install oudoor lighting.  Plan check for energy only.Note: Permit issued under 11041-90000-05083	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66662	15041-10000-24999	1526 S LA CIENEGA BLVD	90035	10	129B173   761	5068006002	C2-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.04961	-118.37594	PC AT COUNTER FOR T-24 ENERGY ONLY AT A PANDA EXPRESS RESTAURANT. THE SCOPE OF WORK INCLUDES NEW EQUIPMENT, LIGHTING, AND RECEPTACLES. SQ FT = 1,245	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66663	14041-20000-34285	9410 N WOODLEY AVE	91343	12	198B141   197	2671015003	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.24142	-118.48481	PV1. INSTALL ROOF MOUNTED SOLAR ARRAY. INTERCONNECTED WITH MAIN SERVICE PANNEL. SYSTEM SIZE 7.5 KW.(39) KYOCERA KU2556XCA MODULES(1) FRONIUS IG PLUS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66664	17041-10000-23956	11979 W WALNUT LANE unit #2	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.03749	-118.4591	Install new rooftop solar system, 2kW AC. (8) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66665	13041-10001-27132	738 1/2 E BROOKS AVE	90291	11	111B145  1292	4239013027	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	33.99733	-118.46493	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66666	12041-10000-16053	10250 W SANTA MONICA BLVD Space 135	90067	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING RETAIL SPACE #125. FLIP FLOP SHOP. PERMIT FOR NEW XFMR PANEL, AND BRANCH CKTS. LESS THAN 400A LOAD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66667	16041-20000-36212	15345 W SHERMAN WAY Space R	91406	6	183B145    43	2222027039	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.20139	-118.46766	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use/tenant improvement. Total lighting area = 675 sq. ft.Note: Building permit has been pulled under 16016-20000-17706	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66668	10041-20001-20549	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	06/06/2011 12:00:00 AM	ADDRESS	34.27455	-118.56289	Plan check power and energy for site lighting supplied from panel in parking structure.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66669	17041-20001-39319	1545 S FAIRFAX AVE	90019	10	129B173   994	5068021007	[Q]R3-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Apartment			05/29/2019 12:00:00 AM			PC Approved	05/29/2019 12:00:00 AM	ADDRESS	34.04831	-118.36762	Revisions to approved set of plans.  Elevator phase converter location change and disconnect/conductor details.  (((New 4-story 10-unit apartment building over one level subterranean garage.  600 A 120/240V 1ph-3w service.  Plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66670	18041-20002-10667	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM			PC Approved	06/21/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	"06-21-2019 Changes to an approved  set plan, Changes include remove panel ""LP1"" and change scope of work to install ""EV"" panel and associate equipment to Future. All Changes has been clouded as delta 7. Plan check only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66671	12041-20000-29216	6640 N VAN NUYS BLVD #202	91405	6	180B149   272	2237001018	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.19188	-118.44844	Change to lighting in an existing 2-story office building.   Load is less than 40 amps per applicant.  PLAN CHECK ONLY for Energy, with NO Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66672	12041-10000-11785	13429 W VANOWEN ST	91405	2	183B157   950	2328031012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			05/22/2012 12:00:00 AM	05/17/2013 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.19412	-118.42557	PLAN CHECK FOR POWER AND ENERGFY. NEW 4 STORY 23 UNIT APARTMENT AND A REC. ROOM OVER SUBTERRANEAN GARAGE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66673	16041-10001-16196	827 E 3RD ST	90012	14	129A215   261	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	34.04599	-118.23556	Change to approved set by modifying the manufacture name and model number of fixtures on the lighting fixture schedule per customer request. All changes are under delta_12 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66674	18041-20000-01275	350 S GRAND AVE Floors 8-12	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for power and energy. Project site is the 8th through 12th floors of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 114,000 sq. ft.Note: Building application has been generated under 18016-10000-00563	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66675	16041-20000-02171	400 S HOPE ST 20th Floor	90071	14	130-5A211  41	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for energy only. FULL FLOOR TI  FOR  OFFICES ON 20TH FLOOR. New lighting (incl. emergency) and receptacles. 23,771sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66676	17041-10001-24862	5016 N CASPAR AVE	90041	14	162A223   243	5686004014	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	09/18/2017 12:00:00 AM	ADDRESS	34.13749	-118.21305	PC FOR POWER AND ENERGY. PC FOR LIGHTING UPGRADES AND ASSEMBLY HALL. PC ONLY - PERMIT COVERED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66677	14041-10000-11982	1375 N BROADWAY	90012	1	138A217   115	5414023031	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural	YES	2060.10	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	PIN	34.07140676	-118.23068943	Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66678	16041-20001-45431	5725 E YORK BLVD	90042	14	154-5A229  74	5484010016	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.11887	-118.19277	09/19/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 8. Loads have been revised to reflect field installation. *****Previous Work Description*****FULL PC FOR A NEW MCDONALDS RESTUARANT. SCOPE INCLUDES A NEW 1000A 1230/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 27988 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66679	13041-10000-04488	955-959 W ADAMS BLVD 1-41	90007	1	123A201    75	5124010021	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Apartment			02/21/2013 12:00:00 AM			Reviewed by Supervisor	03/29/2013 12:00:00 AM	ADDRESS	34.03148	-118.28302	INSTALLATION OF NEW SERVICE UPGRADE. NEW PANELS AND CIRCUITS. PC FOR POWER AND ENERGY. NEW EQUIPMENT RATED >600A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66680	10041-10000-18949	5353 S GROSVENOR BLVD	90066	11	105B161   730	4211006001	M2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	11/29/2010 12:00:00 AM	ADDRESS	33.98293	-118.41421	T.I. to existing space - conference room.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66681	13041-10000-16272	8201 W BEVERLY BLVD STE500	90048	5	138B173   380	5514008046	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.07624	-118.36815	permit to be pulled at EPC counter only. TI TO EXISTING OFFICE. PC FOR ENERGY ONLY. STE 500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66682	16041-20000-20901	6615 N VALJEAN AVE	91406	6	180B137   263	2233031044	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.19077	-118.48601	PLANCHECK FOR T24 ENERGY. INDOOR STORAGE UNIT. 9000SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66683	14041-10000-18370	11841 W ROSE AVE	90066	11	117B153   491	4250003007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.01762	-118.43764	Install roof mounted solar pannels with with microinverters, junction box, and load center.  Total size = 5.225 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66684	11041-10000-25851	6010 N COUNTY OAK ROAD	91367	3	177B085   298	2032003080	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2011 12:00:00 AM	12/30/2011 12:00:00 AM		Permit Expired	01/22/2014 12:00:00 AM	ADDRESS	34.18091	-118.66742	Plan check 13.16KW roof mounted photovoltaic system single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66685	18041-10000-32278	14746 W RAYMER ST	91405	6	189B149   537	2210025048	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Issued	08/24/2018 12:00:00 AM	ADDRESS	34.21252	-118.45463	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66686	17041-10000-19438	8019 N HASKELL AVE	91406	6	189B141    42	2206004011	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Issued	06/09/2017 12:00:00 AM	ADDRESS	34.21621	-118.47511	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66687	14041-10000-21264	9908 W KIP DR	90210	5	147B153    94	4356006001	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.10126	-118.43313	1 inverter 6000 Watts. 4 source ciruits, 32 modules. System size: 8.16kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66688	11041-10000-11122	1505 N EDGEMONT ST 4th & 5th-Floor	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM			PC Approved	06/07/2011 12:00:00 AM	ADDRESS	34.09843	-118.29637	T.I. for an existing medical office space on the 4th & 5th floor.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66689	13041-10000-25831	900 W WILSHIRE BLVD P2-P5	90017	14	130-5A209 197	5144008020	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Closed	06/20/2014 12:00:00 AM	ADDRESS	34.05001	-118.25963	PLAN CHECK FOR CONDUIT AND JBOX INSTALLATION ONLY FOR P2 THRU P5. NO ELECTRICAL DEVICES OR WIRING TO BE INSTALLED. LIGHTING AND DEVICES SHOWN ON PLAN ARE FOR FUTURE. P1 LEVEL NOT PART OF SCOPE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66690	15041-10000-18295	5428 N FIGUEROA ST	90042	1	151-5A227 354	5468014028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.10766	-118.19633	NEW FIRE ALARM SYSTEM FOR TYPE B OCCUPANNCY  WITH A3. 80 FA DEVICES AND ONE CONTROL PANEL AND 2 ANNONCITOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66691	12041-10000-04830	5601 N VAN NUYS BLVD	91411	2	174B149   818	2244027001	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00, 1285.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	03/02/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	PIN	34.17244487	-118.44939749	NEW SPRINKLER MONITOR SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66692	17041-20000-16223	6900 S MCKINLEY AVE	90001	9	102B205   386	6007015017	M3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.97662	-118.26125	service upgrade 600A to an existing commercial building.  Panels only no circuits.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66693	19041-20000-36568	1031 S BROADWAY	90015	14	126A209    79	5139013014	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM	03/07/2023 12:00:00 AM		Permit Finaled	05/13/2024 12:00:00 AM	ADDRESS	34.04041	-118.2583	New emergency generator, distribution, power, and lighting for roof deck improvements.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66694	10041-10000-01991	21524 W VENTURA BLVD	91364	3	171B105    60	2168001053	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			02/04/2010 12:00:00 AM	03/09/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.16796	-118.59944	TI - existing space --> new hair salon.  Permit is for new panel and associated ckts & equipment.  P/C is for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66695	11041-10000-16122	1540 S CARDIFF AVE	90035	5	129B169   499	4306018014	R1-1	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2011 12:00:00 AM			Verifications in Progress	08/11/2011 12:00:00 AM	ADDRESS	34.05122	-118.39194	Interactive photovoltaic system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66696	15041-10000-25064	11734 W AVON WAY apt# 101	90066	11	111B161  1318	4233022***	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM			Reviewed by Supervisor	08/12/2015 12:00:00 AM	ADDRESS	33.99813	-118.41672	pv1, install 2.65 roof-mounted solar array on a single family house.(10) modules:kyocera ku2656zpa (1) inverter: abb pvi-3.0-outd-s-us-z-a	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66697	14041-20000-15071	8245 N WOODMAN AVE	91402	6	192B153   835	2213016021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.22058	-118.43277	Commercial restaurant TI, change of use from retail to restaurant.  Plan check for Title 24 Part 6 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66698	13041-10000-26233	520 W 148TH ST	90248	15	075B201   220	6119009025	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	33.89795	-118.28396	PV1 3KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: PVI-3.0-OUTD-US ] [( 12) MOD: TRINA {TSM-250PA05.08}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66699	15041-10000-33233	7652 N TUJUNGA AVE	91352	6	186B173    69	2315010040	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	PIN	34.20995941	-118.37872208	PVI, INSTALL NEW 6.867 KW DC ROORF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(21) MODULES: SUNPOWER SPR327NE-WHT-D(2) INVERTER: ABB PVI-3.8-OUTD-S-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66700	10041-20000-08557	6701 N ETON AVE	91303	3	180B105    27	2148030035	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	09/30/2010 12:00:00 AM	ADDRESS	34.19217	-118.59564	TI FOR OFFICE AREA IN WAREHOUSE.  POWER AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66701	18041-20000-30743	11248 W SUNBURST ST	91342	7	213B173   226	2530035017	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.27971	-118.37639	Plan checkf or PV roof mounted system, system size: 7.6kW with 23 PV modules and 1 inverter(7.6kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66702	15041-10000-03881	8680 W PICO BLVD	90035	5	132B169  1060	4303011002	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			02/09/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.05411	-118.38117	Plan check for a service upgrade from a 400-amp service to a 600-amp. Main switchboard will also be upgraded to a 600-amp rated panel. Project also included the installation of (1) 200-amp subpanel and associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66703	13041-20000-28019	333 S HOPE ST 33RD FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC FOR T24 ENERGY ONLY. TOTAL AREA 1170 SQ FT. CONFERENCE ROOM. NEW LIGHTING. WORK DONE IN 33RD FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66704	17041-10000-00848	8060 W JOVENITA CANYON ROAD	90046	4	153B173   794	5565018002	RE11-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2017 12:00:00 AM	01/18/2017 12:00:00 AM		Issued	01/18/2017 12:00:00 AM	ADDRESS	34.11342	-118.37315	PV1 roof mounted solar sytem installation to a single family home. New 10.0 KW central inverter being fed from 35 solar modueles.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66705	11041-10000-14532	10250 W SANTA MONICA BLVD Space 1260	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I.  Going from a Ben And Jerry Ice Cream shop to a Yogourtland.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66706	13041-10000-11335	825 S HOBART BLVD	90005	10	132B193   741	5093015020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM	05/14/2013 12:00:00 AM		Permit Expired	06/09/2015 12:00:00 AM	ADDRESS	34.05679	-118.30549	Existing fire alarm panel to be replaced with new fire alarm panel (Edwards iO64) and remote graphic annunciator.  Existing notification appliances and signaling devices to remain.  The scope of this plan check is adding one SD and repalcing a panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66707	15041-10001-16415	11818 W WILSHIRE BLVD UNIT 300-PHASE 3	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.0474	-118.46308	UPDATED BACKGROUND TO SHOW THE SINK RELOCATION, SHIFTED OUTLETS FOR RELOCATION OF SINKS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66708	19041-10000-14790	818 N HILL ST	90012	1	135A215   289	5408032026	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	34.06338	-118.23906	PC FOR Restaurant TI ON FIRST FLOOR OF THREE STORY HOTEL FOR T-24 ENERGY ONLY.SCOPE INCLUDES NEW PANEL, EQUIPMENT, LIGHTS. TOTAL AFFECTED AREA 3284 SQ. FTB#18016-100000-02848	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66709	16041-10001-06084	1245 W WILSHIRE BLVD 1ST FLR	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Expired	04/04/2018 12:00:00 AM	ADDRESS	34.05373	-118.26606	Supplemental PC and permit to 16041-10000-06084: T-24 on (E)  office and (E) storage room within 1st floor Good Samaritan Hospital Mail room. Total area: 803 sq.ft.  <<INSTALL 6 LIGHT FIXTURES 1 OUTLET ON THE 1ST FLR.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66710	19041-10000-29142	6854 S LA TIJERA BLVD	90045	11	102B173   161	4103002030	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Issued	09/23/2019 12:00:00 AM	ADDRESS	33.97614	-118.37283	INSTALL (65) FIRE ALARM DEVICE, (1) FIRE ALARM PANEL, COMMUNICATOR AND (2) ANNUNCIATORS FOR A COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66711	13041-10000-14636	1925 W 65TH ST	90047	8	105B193  1303	6016006021	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/18/2013 12:00:00 AM		Permit Expired	07/13/2015 12:00:00 AM	ADDRESS	33.9807	-118.31193	PV1 4.251KW XFRMLESS. 1 STORY HOUSE. NONSTD. ROOFMOUNT. (1)POWERONE PVI-3.6-OUTD-US and modules (13) sunpower SPR-327-NE-wht-D. 2 strings	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66712	13041-10000-22255	8010 W MELROSE AVE	90048	5	141B177   615	5527015003	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			Corrections Issued	08/19/2013 12:00:00 AM	PIN	34.08351029	-118.36421282	Change of use from retail to take-out restaurant.  T24 for commercial TI (pastry shop).  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66713	15041-10000-04388	2902 S CENTRAL AVE	90011	9	117A209   130	5119016002	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.20	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.01542	-118.2561	Plan check for T-24 only. Remove HID light fixtures and replace with new LED fixtures. Total area: 13280 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66714	16041-10000-29778	17325 W CASTELLAMMARE DR 1-29	90272	11	126B117   727	4416003038	[Q]RD2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			08/22/2016 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	06/16/2020 12:00:00 AM	ADDRESS	34.03943	-118.55625	Plan check for New appartment Builidng 29 units 5 story over 2 level of parking. Total area: 58,106sq ft. Fire alarm Variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66715	17041-20002-09270	18521 W DEVONSHIRE ST	91311	12	204B125   100	2728028025	C2-1, C2-1VL, P-1VL, PB-1, RE15-1-H	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	PIN	34.25832638	-118.53687182	Revisions to approved set of plans.  Addition of irrigation pump, service area sconce lighting circuit.  Revised AC loads.  Approval for clouded revisions delta 9 and 11 only.  (((Plan check for power and energy for new restaurant Chick-Fil-A 1200A Service 1 story. Total area: 5,279 sq ft)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66716	18041-10001-25290	300 S GRAND AVE	90071	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM			PC Approved	12/06/2019 12:00:00 AM	ADDRESS	34.05283	-118.25116	PLAN CHECK ONLY FOR REVISIONS TO LIGGTHING PLAN, SHOWING THE LOCATION OF EXIT SIGNS ALL CHANGES ARE CLOUDED UNDER DELTA 3ORGINAL SCOPE OF WORK ((PC FOR INSTALLATION OF NEW OUTDOOR RATED GENERATOR WITH FUEL TANK,  FOR EXISTING LOADS. TOTAL 200 SQ.FT.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66717	15041-10000-37109	18938 W SAN JOSE ST	91326	12	207B121   843	2728017011	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.26011	-118.54603	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222PV1, INSTALL 16.5KW ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.(56) MODULES: SUNPOWET SPR327NE-WHT(3) INVERTERS: SMA TRANSFORMERLESS - 7.7Kw, 5kW, 3.8kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66718	18041-10000-37427	8734 S BELLANCA AVE	90045	11	096B169   844	4125018007	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2772.00	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	33.95765	-118.38038	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66719	17041-10001-23289	2780 N LA CASTANA DR	90046	4	156B177   671	5570002029	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM			Reviewed by Supervisor	07/17/2017 12:00:00 AM	ADDRESS	34.12103	-118.35768	EXPEDITE FEE PER APPLICANT REQUEST************************************************************PLAN CHECK FOR ROOF MOUNTED PV FOR SFD. SYSTEM INCLUDES ENERGY STORAGE SYSTEM (WALL POWER PACK). PV SYSTEM SIZE 7.6KWACINCLUDING 17  MOUDULES PV SYSTEM SIZE 7.6KWACESS SYSTEM SIZED AT 5.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66720	18041-10001-37033	2003 W JEFFERSON BLVD	90018	10	120B189   674	5052023038	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2220.01	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM			PC Approved	11/06/2018 12:00:00 AM	ADDRESS	34.02567	-118.31537	SUPPLEMENTAL TO APPROVE SET OF PLAN PLAN CHECK INCLUDES REMOVING OF EMERGENCY LIGHTING  FROM BATHROOM AND KITCHEN, REPLACE EMERGENCY LIGHT WITH BATTERY PACK FOR STUDIO 2 AND 3ORIGINAL PLAN NUMBER: 18041-10000-37033B#17016-10000-22551	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66721	18041-20000-08198	1950 S SAWTELLE BLVD	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.04129	-118.44377	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the common corridors and restrooms. Total lighting area = 5,616 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66722	15041-10000-29375	748 N WILCOX AVE	90038	4	141B185   334	5533034020	R3-1	Central	Hollywood			1918.00	Electrical	Electrical	Apartment			09/04/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.0849	-118.33084	INSTALL NEW FA SYSTEM FOR A NEW 4-STORY, 36 UNITS APARTMENT BUILDING WITH (164) DEVICES AND ONE CONTROL PANEL AND ONE COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66723	19041-20000-53215	676 N ELKINS ROAD	90049	11	135B137    59	4426033016	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.06993	-118.49092	PV1. INSTALL 13.30 KW DC PV SYSTEM WITH (38) MODULES, OPTIMIZERS AND (1) INVERTER (SE10000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66724	16041-10000-28197	1933 E 113TH ST	90059	15	087A215   181	6067004010	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2431.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	33.93257	-118.23781	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.85KWdc / 3.36KWac.(14)MODULES-SOLARWORLD SW 275 MONO(14)MICROINVERTERS-ENPHASE ENERGY M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66725	13041-20001-05654	19330 W PLUMMER ST	91324	12	198B117    73	2761037001	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM			PC Approved	07/10/2013 12:00:00 AM	ADDRESS	34.2426	-118.55515	(((This is application for restamp. lost approved set. pc for additional hours to verify plans and restamp.no permit to be issued from this application. permit to be issued from original application still. )))Remodeled Ross Dress For Less.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66726	13041-20000-18634	4837 E HUNTINGTON DR NORTH	90032	14	142-5A233  36	5213002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			07/15/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	34.08619	-118.17919	T24 FOR LOW RISE OFFICE SPACE. TOTAL SQRFT 675. THE SPACE IS USED FOR CONSULTATION ONLY, NO MEDICAL EQUIPMENT INSTALLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66727	18041-20000-48410	7304 N HINDS AVE	91605	2	186B169   878	2317018027	[T][Q]MR1-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.2032	-118.39093	Plan check for PV roof mounted system, system size: 2.6kW DC, 3.0kW AC wtih 8 PV modules and 1 inverter(3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66728	13041-10000-16104	10929 W WEYBURN AVE	90024	5	135B149   585	4363018010	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/18/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.06274	-118.44635	permit to be pulled at EPC counter only.  pc for energy only.TI TO (E) RESTAURANT. BAR REMODEL. less than 400A per applicant and not touching on emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66729	12041-10003-20350	5755 W 96TH ST	90045	11	093B169   128	4125021024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			Corrections Issued	08/13/2013 12:00:00 AM	ADDRESS	33.94955	-118.38214	ELECTRICALSERVICE  UPGRADES FOR  THE 1ST FLOOR PRODUCTION AREANOTE THAT # 12041-10000-20345 IS FOR THE TI WORK(((((( 8-13-13  supplemental for fault cals and sht ckt anal.)))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66730	13041-10001-36029	5219 N NORWICH AVE	91411	4	172-5A147 232	2250019026	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.16547	-118.46087	Expedited RSES plan check per applicant request.{{PV1, Install 4.25 kW DC roof-mounted solar array for a one story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (17) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66731	14041-10001-35567	725 S BIXEL ST 1-328	90017	1	130-5A207 631	5143004012	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			12/23/2014 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.0501	-118.26506	Void.......fee is too high, customer've decided to submit it in as a regular process.Expedite per customer request.(((225KW roof mounted PV system  for a six-story aparment complex. system including (1296) Canadian Solar CX6X modules, (10) combiner box and (1) central Solectria SGI 225PE inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66732	13041-10000-27871	20858 W COLLINS ST	91367	3	174B109   357	2149015017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.17333	-118.58734	PV1 7.5KWdc. 240V. negative GND. STD PLAN. 1story. Roofmount. [(1) inverters: {Fronius IG PLUS V 7.5-1UNI}]. [(30)modules: {Trina {TSM-250PA05.08}}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66733	14041-10000-05801	1302 W 177TH ST BLDG A	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	INSTALLATION OF A FIREALARM FOR A NEW THREE STORY 33-UNIT APARTMENT BUILDING (BUILDING A). 1 PANEL AND 89 DEVICES.1 OF 6ELECTRICAL P# 13041-10000-06846.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66734	13041-10000-34002	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/06/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	PLAN CHECK FOR T24 ENERGY ONLY. MIXED USE BUILDING. T.I. PREVIOUSLY BIKE RACK SPACE CONVERTED INTO MAINTENANCE SPACE. 1541 SQFT, EMERGENCY LIGHTING. PERMIT ALREADY PULLED UNDER 13041-10000-33518.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66735	18041-10000-14774	20630 W LEMAY ST	91306	3	180B109   349	2148019003	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM			Corrections Issued	04/23/2018 12:00:00 AM	ADDRESS	34.19091	-118.58201	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 23 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER. TOTAL SYSTEM SIZE 6.67 KWDC / 6.0KW AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66736	15041-20001-44010	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM			PC Approved	09/12/2016 12:00:00 AM	ADDRESS	34.2215	-118.42999	((9/12/2016))CHANGES TO AN APPROVED SET OF PLANS.  REVISED T-24 AND LIGHT FIXTURES.  CHANGES NOTED DELTA 2 ONLY.  THIS IS PLAN CHECK ONLY. Plan check Power and Energy for Kaiser Permanente Department of Blood Draw. Total area: 3,652 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66737	15041-10000-35554	515 S FLOWER ST 52 FLR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	"REPLACE (2) EXISITNG DITRIBUTION BOARDS ""EDP 52 N-B AT 1200 AMPS AND EDP 52 N-A AT 400 AMPS"" LIKE FOR LIKE.  NO NEW ADDED LOADS.  PLAN CHECK FOR POWER ONLY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66738	10041-10000-07931	333 S HOPE ST Suite 2300-23rd floor	90071	9	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.05326	-118.25292	T-24 and emergency lighting for a portion of  suite 2300, on the 23rd floor.  Permit is for new lighting and power circuits only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66739	18041-20001-19172	3705 N MARFIELD AVE	91356	3	162B121   113	2177043028	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.13698	-118.55053	Expedited plan check fee. PV1.  Install 18.2 kW roof mounted grid tied PV system.  (56) modules with (2) 7.6 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66740	16041-20001-05745	21834 W RODAX ST	91304	3	192B105   337	2779039003	RS-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.22341	-118.60413	Expedited per applicant request.Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 5 kWac for a total system size of 11 kWac. Addition consists of (1) inverter, (26) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66741	15041-10000-16653	5898 W VENICE BLVD	90019	10	126B173   696	5064029908	PF-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.03982	-118.36923	NEW SERVICE, PC FOR POWER ONLY. NEW COMPRESSED NATURAL GAS STATION.  LOCATED ON CITY FACILITIES- HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66742	19041-10000-17864	4515 N EAGLE ROCK BLVD	90041	14	157-5A221  80	5473037007	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	06/10/2021 12:00:00 AM	ADDRESS	34.12659	-118.219	PC FOR POWER AND ENERGY(LOT 20-26). SCOPE INCLUDES A NEW 800A SERVICE FOR 7 SFD. TOTAL AFFECTED AREA IS 42218 SQ. FT. ENERGY PC UNDER MASTER 19041-10000-17858.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66743	18041-10000-29158	575 W PACIFIC COAST HWY	90744	15	036B205  1108	7421027032	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.791	-118.26935	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66744	12041-10000-27243	110 S AVENUE 56	90042	1	151-5A229 359	5468025001	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.10857	-118.1938	TI TO BEAUTY SALON THAT USED TO BE WAREHOUSE. 1333 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66745	19041-10000-12287	624 N EVERGREEN AVE	90033	14	129A227   349	5178011029	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Issued	04/04/2019 12:00:00 AM	ADDRESS	34.04623	-118.19854	PV1(SYSTEM 2) SYSTEM SIZE 6.20KWdc/ 5.25KWac, 21 MODULES CANADIAN SOLAR CS6K-295MS. 21 MICROINVERTERS ENPHASE IQ 7-60-2-US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66746	11041-10000-20339	11950 W LOPEZ CANYON ROAD	91342	7	216B165    24	2526003909	OS-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.02	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	04/02/2012 12:00:00 AM	ADDRESS	34.28787	-118.40055	ELECTRICAL HOOKUP TO A PRE-FABRICATED BUILDING IN A METHANE ZONE.  NEW 400A AMP BOARD WITH FEEDERS.   PLAN CHECK REQUESTED BY APPLICANT FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66747	13041-10000-33879	2970 W OLYMPIC BLVD	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.05241	-118.29951	Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.New roof mounted PV system with 31.5 KW include two new subpanels.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66748	15041-20000-20548	3442 N COLVILLE PL	91436	5	159B137   284	2287012046	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.1329	-118.49628	"""$0 permit fees due to senate bill 1222""PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel.(56) Kyocera KU2656 Modules(2) PVI-6000 TL Inverters"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66749	16041-10000-11158	8700 W BEVERLY BLVD	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Expired	05/21/2018 12:00:00 AM	ADDRESS	34.07666	-118.3805	PC FOR ENERGY ONLY FOR SIGN LIGHTS ON DIFFERENT FLOORS OF A CEDARS SINAI HOSPITAL. TOTAL AREA 83.75 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66750	16041-10000-32651	6430 S WEST BLVD	90043	8	105B185  1167	4006007031	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	33.98084	-118.33502	PC FOR TITLE 24 ONLY.SCOPE INCLUDES NEW LIGHTING FOR OUTDOOR PARKING. SPACE TOTAL AREA  9250 SQ0FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66751	16041-10000-42963	700 W 7TH ST # G720	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	Plan check Title 24 only in existing space T.I. space # G720. Total area: 1,806 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66752	14041-20002-00836	1102 W 6TH ST	90017	1	132A207   306	5143024011	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			Reviewed by Supervisor	05/19/2015 12:00:00 AM	ADDRESS	34.05397	-118.26245	04-23-15 Change to approve set. Changes apply to delta 1 and 2 only; list of changes is included E-004. Fees are provided by the applicant.  ((((((New 606 Unit mixed use apartment/commercial building.  350,000 sq. ft, with three 3,000 amp services.  <<Engineer to verify fees for FINAL.>>  Variance to separate fire alarm has been paid.))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66753	15041-10000-01526	6875 S HOOVER ST	90044	8	102B197   586	6013008029	C2-1VL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	33.97745	-118.28727	installation of roof-mounted solar array, interconnect with main panel. System size: 3.315kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66754	14041-20002-26800	20664 W VENTURA BLVD	91364	3	171B109    75	2166013101	(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	01/16/2015 12:00:00 AM	PIN	34.16660198	-118.58290188	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES TO LIGHTING FIXTURES NOTED ON PLANS DELTA 1.TI TO AN EXISTING COMMERCIAL BUILDING 2250 SQFT SINGLE STORY, PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  ADDING LIGHTING TO EXISTING POWER EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66755	16041-10001-00290	1070 S BEDFORD ST 1-19	90035	5	132B169   448	4332021027	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			06/30/2017 12:00:00 AM			PC Info Complete	08/14/2017 12:00:00 AM	ADDRESS	34.0573	-118.38026	FULL PC FOR LOST SET OF PLANS FOR A NEW 19-UNIT APARTMENT BUILDING. TOTAL AFFECTED AREA IS 22661 SQ. FT. Note: Permit pulled under master application. 16041-10000-00290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66756	18041-20000-10194	242 S AVONDALE AVE	90049	11	129B137   150	4406019011	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM			PC Approved	05/01/2019 12:00:00 AM	ADDRESS	34.05225	-118.49181	(N) two story SFD with attached garage and basement.  Plan check only for power.  600A 240/120V single phase service.Building and electrical permits issued under 17010-30000-02532.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66757	14041-20001-25301	10739 W STALLION RANCH ROAD	91040	7	204B177   260	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	34.25715	-118.36484	FEE CHARGE IS $0.00 BY STATE SENATE BILL NO. 1222EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL GROUND MOUNT PV SYSTEM SIZED 18KW INTERCONNECTED WITH MSP.(80) CANADIAN SOLAR 250 MODULES(80) ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66758	19041-20000-34173	20600 W WOOD ROSE CT	91326	12	219B109   547	2701102037	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	34.29524	-118.58256	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66759	16041-10001-02353	13274 W FIJI WAY STAIRWELL	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM			PC Approved	03/07/2018 12:00:00 AM	ADDRESS	33.97902	-118.43558	PC FOR REVISIONS TO APPROVED SET UNDER DELTA 2 & 3. SCOPE INCLUDES CHANGES TO LIGHTING CONTROL SYSTEM AND MINOR REVISION PER INSPECTION. THIS IS PLAN CHECK ONLY. PERMIT UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66760	16041-10003-30643	835 W JEFFERSON BLVD 7-D	90007	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES REVISIONS FIXTURE SCHEDULE AND T-24 FORMS TO REFLECT FIELD INSTALLATION. THIS IS PLAN CHECK ONLY!PERMIT PULLED UNDER ORIGINAL.************************************************************************************TO PC FOR POWER AND ENERGY FOR A FIRST TIME TENANT FOR A PERVIOUSLY APPROVED TITLE 24  SET. SCOPE INCLUDES CHANGES IN LIGHTING AND ADDING NEW LOAD. NEW CONNECTD LOAD FOR EQUIPMNET AND RECEPTACLES. *******************************************************(TI FOR OFFICE SPACE IN EXISTING ROOM. NEW LIGHTING. WORK DONE IN BUILDING 7 SUITE 7-D PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66761	13041-10000-27872	2226 S RAYMOND AVE	90007	8	123B197   302	5054018020	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	04/01/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.03547	-118.29741	PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(12)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}. (E) 400 MAIN SERVICE PANEL, WITH (E) 4X60/2P MAIN CKT BREAKER.]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66762	17041-10002-33180	6540 W SUNSET BLVD	90028	13	147A187   165	5547026024	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM			PC Approved	05/04/2018 12:00:00 AM	ADDRESS	34.09782	-118.33292	DELTA 3 Changes to approved plans. Changing light fixtures to LED. Title 24 Energy ONLY in an office building.=================12.4.2017 - Plan check for modifications to approved set. Changes clouded delta 2. Update lighting control system. Revise lighting design - update T24 forms and fixture schedule. Change exit signs to self-illuminating.======PC FOR OFFICE TI IN (E) A TWO STORY BLDG. TOTAL CONNECTED LOAD <400A  TOTAL AFFECTED AREA 6696 SQ.FTSCOPE INCLUDES NEW PANELS, CIRCUITS, LIGHTS AND EQUIPMEMNT. B#17016-20000-09488	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66763	17041-10000-10989	15533 W EL CAJON ST	91342	7	222B145   235	2604013020	RA-1-K	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.30372	-118.47036	PV SYSTEM. TOTAL OF 24 MODULES AND CENTRAL INVERTER 7KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66764	14041-10000-25480	13780 W RAYEN ST	91331	6	198B153   948	2640004022	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.23545	-118.43335	Standard Plan PV1 roof-mounted system with (1) combiner box, (1)  6KW inverter and (34)Kyocer kd255 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66765	15041-20000-28101	15121 W RAYEN ST	91343	7	195B145   233	2654006154	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.23199	-118.4617	New fire alarm system inside a new 20-unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66766	10041-10001-19732	520 S VIRGIL AVE # 306	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM			PC Info Complete	11/10/2010 12:00:00 AM	ADDRESS	34.06457	-118.28687	CHANGE OF USE  CONVERTING AN OFFICE SPACE TO ORTHODONTIST'S OFFICE floor p;an chaned from b-4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66767	14041-10000-27240	8435 N TELFAIR AVE	91352	6	192B169   407	2632023038	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			10/02/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.22324	-118.38311	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 7584 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66768	14041-20000-28009	630 S MASSELIN AVE	90036	4	135B181   759	5508014037	R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.06378	-118.35237	REPLACEMENT TO EXISTING FIRE CONTROL PANEL. PLAN CHECK FOR BATTERY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66769	18041-10000-26694	9301 N TAMPA AVE 3RD Floor	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM			Verifications in Progress	10/16/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVEMENT TO (E) RETAIL STORE (MACY'S) ON THE 3RD FLOOR. WORK AREA 37,746 SQFT. T-24 ENERGY ONLY. BUILDING PERMIT: 18016-1000-22785	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66770	11041-10000-11755	21730 W SHERMAN WAY	91303	3	183B105   151	2111025002	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	04/09/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.20086	-118.60267	CHANGE OF USE FROM RETAIL TO RESTAURANT IN EXISTING SINGLE STORY BUILDING.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66771	10041-10000-25845	928 S WESTERN AVE #302	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	12/30/2010 12:00:00 AM	ADDRESS	34.05485	-118.30886	TI AT A SHOPPING MALL & FAMILY LOUNGE ( ACCESSORY SPACE  TO SHOPPING MALL ). (NO CHANGE OF USE). CREATING NEW STOREFRONT AND FILL IN A FIRE RATED DOOR.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66772	17041-20003-44865	23002 W SYLVAN ST	91367	3	177B097   149	2039010028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2018 12:00:00 AM			PC Approved	04/27/2018 12:00:00 AM	PIN	34.1842535	-118.62796555	Revision to approved set.  Approval for delta-4 revision only.  Wiring detail changes.(((Revision to approved set.  Relocation of equipment to match DWP meter spot.  PV1.  Install 24.08 kW roof mounted grid tied PV system.  (72) AC modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66773	12041-20000-00926	10880 W WILSHIRE BLVD s.2240	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.05885	-118.44283	S.2240 OFFICE T.I.Energy, emergencyFire Alarm system is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66774	13041-10000-05051	18700 W VENTURA BLVD #150	91356	11, 3	174B121   811	2161026002	(Q)C2-1VL, C2-1VL, R1-1	South Valley, West Los Angeles	Encino - Tarzana, Palms - Mar Vista - Del Rey	Mar Vista, Tarzana		1394.01, 2719.02	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Closed	06/14/2016 12:00:00 AM	ADDRESS	34.17045	-118.54081	TI OF EXISTING RETAIL SPACE FOR RETAIL. NO CHANGE OF USE. PC FOR T24 ENERGY ONLY. TOTAL AREA 1261 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66775	16041-10000-39593	4600 W COLORADO BLVD	90039	13	162B205   273	5593018903	PF-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM			Reviewed by Supervisor	12/09/2016 12:00:00 AM	ADDRESS	34.14094	-118.27314	PC FOR HAZARDOUS AREA. INSTALLING NEW PUMPS AND LIGHTING. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66776	15041-20004-24184	8842 W FOOTHILL BLVD	91040	7	207B189  1166	2547027005	C2-1L, P-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM			PC Approved	02/23/2018 12:00:00 AM	ADDRESS	34.26086	-118.32514	2/23/2018changes to an approved set of plans.  Changes to reflect field conditions noted delta 7.  changes to include (2) pull sections only.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66777	19041-10000-06571	8151 W 3RD ST Units A-B	90048	5	138B173   879	5511020030	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM			PC Info Complete	03/13/2019 12:00:00 AM	ADDRESS	34.07244	-118.36706	Energy plan check for a change of use from Auto Repair Garage to Retail Stores. Scope includes new lighting and equipment with a total area of 4582-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66778	18041-20000-07907	13506 N HARLEY AVE	91342	7	225B157   909	2510025016	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.31703	-118.43097	PLAN CHECK FOR A ROOF MOUNTEED PV SYSTEM. SYSTEM SIZE = 10.0KVA CONSISTING OF 1 CENTRAL INVERTER (SE 10000H-US) AND 38 MODULES WITH P320 POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66779	16041-20000-00090	15846 W LEADWELL ST	91406	6	186B141   655	2206037126	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.20378	-118.47885	PV1. Install roof mounted PV system sized 7 kW. Interconnected with main service panel. Standard plan.(28) Solarworld SW 285 Modules(28) Enphase M250 Microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66780	17041-20000-17105	6100 N DILL PL	91367	3	177B089   442	2045010020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/22/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.18126	-118.64674	Plan check for solar pv system, roof-mounted on SFD.6.72kW ungrounded system.(21) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66781	18041-10000-09588	15455 W CHATSWORTH ST	91345	7	207B145   260	2649001006	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	ADDRESS	34.26472	-118.46938	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66782	12041-10001-09240	8000 W SUNSET BLVD	90046	5	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			08/21/2012 12:00:00 AM	09/17/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.09783	-118.36466	(((((((((((((((((((((((((((   8-21-12     changes of fixtures for title 24 , addition of  35 new fixtures. plan check previosly approved.       )))))))))))))))))))))))))))Remodel of an existing Movie Theatre with 200A of load per applicant.  Full plan check for Power and Energy is requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66783	14041-10000-13444	4700 W PICO BLVD # D	90019	10	129B185  1011	5083033015	[Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.04846	-118.33732	"SANDWICH SHOP  27-10""X44'-3"" CHANGE OF USE FROM RETAIL TO TENANT IMPROVEMENT PROJECT IN EXISTING SHELL.  FULL PLAN CHK"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66784	13041-10001-32938	12587 W CATHY ST	91342	7	228B161   670	2580006016	RS-1	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.31953	-118.40785	Expedited RSES plan check per applicant request.(((PV1, Install  4.5 kw DC roof-mounted solar array for a 1 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 18 modules: Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66785	17041-20000-09916	8631 W 3RD ST 915 East	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check for power and energy. Project site is a suite on the 9th floor of an existing commercial building. Project scope is a tenant improvement to a medical office. Total lighting area = 3,335 sq. ft.Note: Building permit has been issued under 17016-10000-03658	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66786	15041-10001-28086	801 S FIGUEROA ST 1130	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	*4/13/16: Change to approved set under Delta-2 (change light fixtures and its layout). TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2710. SCOPE TO BE PERFORMED IN THE 11TH FLOOR.#15041-10000-28086	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66787	12041-10000-10648	2970 W OLYMPIC BLVD #304	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	09/11/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	Plan check power and energy for new medical office, first-time tenant. Suite #304. Not check for OSHPD 3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66788	17041-10000-31426	3930 S WISCONSIN PL	90037	8	117B197   954	5037019007	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.01453	-118.29323	PC FOR ROOF MOUNTED PV SYSTEM ON SFD. SYSTEM SIZE 3.36 KW AC  4.06 KW DCSCOPE INCLUDES 14 MODULES WITH 14 MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66789	14041-20000-22921	19726 W HATTON ST	91306	3	186B117    63	2106011037	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.20985	-118.56326	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.1KW INTERCONNECTED WITH MSP.SOLARWORLD POLY SW250 MODULESFRONIUS GALVO 3.1-1 240V INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66790	18041-20001-09192	623 S ARDEN BLVD	90005	4	135B189   912	5505014010	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM			PC Approved	10/24/2018 12:00:00 AM	ADDRESS	34.06288	-118.32599	Revision to approved plan.  Change of 60A non-fused AC disconnect to 60A fused AC disconnect with 50A fuses.$0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.(((Plan check for a PV1 roof-mounted PV system. System size is 8.4 kWac/9.75 kWdc and consists of (30) modules and (30) micro-inverters. Standard plan is not being used.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66791	15041-10000-01592	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	33.79072	-118.29449	PC FOR POWER AND ENERGY. KAISER MEDICAL OFFICE BUILDING. TI. DEMOLITION OF NURSURY ROOM AND MAKING 3 INFUSIONARY ROOM OUT OF IT. TOTAL AREA 415 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66792	17041-10000-06242	1800 S AVENUE OF THE STARS 12TH FLR	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Issued	02/28/2017 12:00:00 AM	ADDRESS	34.06095	-118.41786	PLAN CHECK FOR ENERGY ONLY FOR NEW MEN AND WOMEN RESTROOMS ON 12TH FLOOR (E) OFFICE SPACE.  (B# 16016-10000-24054)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66793	18041-10000-14224	2413 N HYPERION AVE	90027	4	148-5A205  59	5433017013	C1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.10291	-118.27326	Energy plan check for an existing T.I office building. Scope includes new lighting and receptacle with a total of 1150-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66794	18041-20000-18371	1070 S HOLT AVE 1-29	90035	5	132B173   618	4332025020	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			05/17/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	03/17/2021 12:00:00 AM	ADDRESS	34.05732	-118.37817	Plan check for power and energy. Project site is a new 5-story, 29-unit apartment building. Total lighting area = 23,281 sq. ft.Note: Building application has been generated under 15010-30000-03807	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66795	14041-20001-08514	6801 W HOLLYWOOD BLVD #170	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	changes to approved set of plans. changes include change in lighting fixture and removal of fixtures in sales area. corrected sales area in calc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66796	17041-20000-36398	7751 W VERAGUA DR	90293	11	099B153    56	4114002018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	33.96509	-118.43308	PV1.  Install 16.64 kW DC roof mounted grid tied PV system. Microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66797	18041-10000-06114	9142 N OWENSMOUTH AVE	91311	12	198B105   165	2746011008	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.23641	-118.60176	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66798	18041-20001-39049	214 S WESTMORELAND AVE	90004	13	135B197    84	5501020014	R3-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Apartment			11/04/2019 12:00:00 AM			PC Approved	11/04/2019 12:00:00 AM	ADDRESS	34.0698	-118.28773	11/4/19CHANGES TO APPROVED SET DELTA 2 ONLY CHANGES TO SERVICE PHASE.<<<Full plan check for 800-Amp service 120/240v 3- phase 4-wire with new panels, equipments total affected area 8020-SQ FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66799	19041-20000-09615	4347 N CORONET DR	91316	5	165B129   145	2184030004	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.15063	-118.51909	INSTALLING A 10.89KW DC/7.6KW AC ROOFTOP PV SYSTEM. SCOPE OF WORK INCLUDES (1) SE7600 INVERTER, AND (33) PANASONIC 330W PV MODULES WITH P400 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66800	18041-20000-06266	10760 N DEBRA AVE	91344	12	207B137   239	2680013036	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.26644	-118.4901	Plan check for a PV1 roof-mounted PV system. System size is 12.06 kWac and consists of (1) inverter and (38) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66801	18041-10003-03666	11846 N WOOD RANCH ROAD	91344	12	216B129   272	2601066001	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM	04/05/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.28687	-118.52026	PLAN CHECK FOR UPGRADE OF MAIN PANEL FROM 200A WITH 175 MAIN BREAKER TO 225A WITH 175A MAIN BREAKER WITH NO ADDED NEW LOAD Install New PV1 rooftop solar on (E) SFD, system size 15.2kW AC/ 18.85 kW DC. (2) 7.6 kW central inverters, (58) modules with (58) power optimizers, and (1) load center	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66802	15041-20001-01269	4280 N JUBILO DR	91356	3	165B121   295	2177020015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.14926	-118.54292	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM SIZE: 8.48 KW. CENTRAL INVTERTED AND MICROINVERTER SYSTEM(32) SUNEDISON SE-F265(16) ENPHASE M250(1) SMA SB3800	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66803	15041-30000-42248	19418 W LEMARSH ST	91324	12	204B117   315	2726017012	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.25537	-118.55695	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 12 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66804	17041-10000-33923	311 W PACIFIC COAST HWY	90744	15	036B205   998	7421024014	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Issued	09/21/2017 12:00:00 AM	ADDRESS	33.79211	-118.26673	New Fire alarm system on an (E) commercial build. (4) FA panels,  (101) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66805	11041-20002-23441			12	207B129   333	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			05/24/2012 12:00:00 AM			PC Approved	05/29/2012 12:00:00 AM	PIN	34.26535568	-118.52490375	Scope of plan check is to revise the feeder and feeder routing from MS to DB as shown on the single line diagram, Delta 6.  Original plan was permitted on applicaiton number 11041-20000-23441.  Other items indicated as Delta 6 have not been approved or reviewed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66806	15041-10000-20451	6401 W WESTCHESTER PARK	90045	11	096B165   959	4122022928	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	PIN	33.9558423	-118.39937012	plan check for temporary power for construction trailers at LAX (PHASE 1). RESUBMITTAL FOR PLAN CHECK IS REQUIRED FOR THE LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66807	13041-10001-30416	19620 W LOS ALIMOS ST	91326	12	207B117    22	2708011026	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	PIN	34.26768154	-118.56101581	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66808	14041-10000-32432	200 WORLD WAY # 231	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER AND ENERGY. TERMINAL 2 STORAGE, REVISING SOME LIGHTING AND ADDING SOME REFRIGERATION EQUIPMENTS AND SMALL OFFICE.(000) TOTAL AREA 215 SQ FT.PLAN CHECKER TO VERIFY THE FEE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66809	14041-20000-27135	13564 N HERRICK AVE	91342	7	228B145   428	2501014010	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Closed	03/18/2015 12:00:00 AM	ADDRESS	34.3183	-118.46978	pv standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66810	13041-20000-01367	22223 W VENTURA BLVD	91367	3	174B101   447	2169026096	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			PC Approved	01/17/2013 12:00:00 AM	PIN	34.16938217	-118.61094063	Plan check for energy only. 1789sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66811	14041-20000-06257	12180 W MILLENNIUM WEST	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	FULL PLAN CHECK FOR OUTDOOR LIGHTING FOR PLAYA VISTA. THE AREA IS IN A METHANE ZONE AND REQUIRES FULL PLAN CHECK FOR HAZARDOUS LOCATION. T24 HAS BEEN PAID FOR ON APPLICATION#: 14041-20000-06148	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66812	13041-20005-04124	616 S KENMORE AVE	90005	10	135B197  1102	5502028006	CR-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			01/19/2018 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.06289	-118.29646	1/19/2018 Changes to approved set of plans.  Approval for changes clouded and marked delta 6 only.  Subpanel for elevator and associated loads.  Consolidation of two booster pumps into one.  (((10/16/2017 Changes to approved set of plans.  Approval for changes clouded and marked as Delta 5 only.  Deletion of standby generator supplying elevator.)))(((06/28/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes include the addition of a subpanel, re-circuiting home-runs, and minor lighting changes.)))(((5/1/2017changes to an approved set of plans.  changes noted delta 2.  new generator with em lighitng and associated loads in the cooridors and outside podium level only.  general lighitng fixtures changed in common areas.  plan check for energy and power.  2008 title 24.))) (((((Full plan check for new 57 unit apartment. Fire alarm variance has been filed. METHANE Zone.extention granted to 8/19/15)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66813	16041-20001-15701	18421 W ALGIERS ST	91326	12	213B125   633	2870012011	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.27658	-118.53544	Expedited per applicant request.Plan check for an addition of a PV1 roof-mounted PV system. PV addition system size is 3 kWac and consists of (1) inverter, (11) modules, and (1) load center. Total system size is 6.8 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66814	15041-20001-32004	6203 N LANKERSHIM BLVD	91606	2	177B169   328	2335032022	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	34.1834	-118.38599	10/02/2015 Changes to an approved set of plans. Emergency fixtures have changed to unit equipment. Changes have only been made to sheets E-4 and E-4.1*****Previous Work Description*****Title 24 plan check only.  Total area = 1,625 sq. ft.    T.I. to existing retail building.  New lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66815	12041-10000-21204	4557 N SIMPSON AVE	91607	2	168B169   890	2364007013	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2012 12:00:00 AM			Reviewed by Supervisor	09/19/2012 12:00:00 AM	ADDRESS	34.1538	-118.38905	ROOF INSTALLATION OF A 4.8KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66816	17041-10000-07758	14325 W ASTORIA ST	91342	7	222B149  1156	2505019018	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.30565	-118.44562	PC for energy only, indoor and outdoor. Removing and replacing HID fixtures with new LED ones. Area: 117,500.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66817	16041-20000-44428	12414 W EXPOSITION BLVD	90064	11	123B149   857	4259026002	M1-1, M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.03061	-118.45624	New 3 story Type IIIB office builidng (Core & Shell only) over a 2 story Type IA  parking garage.  Plan check for power and energy.  159,887 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66818	14041-20001-25275	12318 N EL ORO WAY	91344	12	219B133   577	2608022021	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.41	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.29446	-118.50438	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.8KW INTERCONNECTED WITH MSP.(30) HYUNDAI HIS-S250 MODULES(30) ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66819	11041-10000-06069	216 E 31ST ST	90011	9	118-5A205  77	5120001014	[Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			Reviewed by Supervisor	05/11/2011 12:00:00 AM	ADDRESS	34.0202	-118.2696	INSTALL 5.6 KW (DC) PV SYSTEM.  ON AN EXISTING COMMERCIAL BUILDING.  (REGULAR PLAN CHECK PER APPLICANT REQUEST.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66820	19041-10000-13158	2121 S AVENUE OF THE STARS #100/180	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Issued	05/15/2019 12:00:00 AM	ADDRESS	34.05554	-118.41342	Full PC for a resturant (change of use). Scope includes one new 100A panel and a few circuits. scope of work area 4,397SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66821	16041-10000-06301	7302 N NESTLE AVE	91335	3	186B125   851	2119027008	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	34.20321	-118.53046	PV1, ROOF MOUNTED SOLAR SYSTEM USING ENPHASE MICROINVERTERS. (28) MODULES AND (28) MICROINVERTERS. TOTAL SIZE IS 7KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66822	11041-10000-23695	5410 N SAN FERNANDO ROAD WEST	90039	13	165B201   258		M2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/04/2011 12:00:00 AM	ADDRESS	34.15046	-118.27445	T.I. to an existing restaurant.  PLAN CHECK ONLY for Indoor lighting only.  Emergency lighting is on a seperately approved plan, per the applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66823	11041-10000-02757	2206 S SAWTELLE BLVD	90064	11	126B153  1034	4260020020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Info Complete	02/11/2011 12:00:00 AM	ADDRESS	34.03796	-118.44083	REPLACE AN EXISTING 400 AMP CB WITH A NEW 1000 AMP WITH NO CONNECTED LOAD FOR FUTURE TENANTS ON THE 2ND FLOOR.  COMPLETE EPC WILL BE REQUIRED BEFORE OCCUPANCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66824	12041-10000-06729	5757 W CENTURY BLVD	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	03/28/2012 12:00:00 AM		Permit Finaled	07/12/2012 12:00:00 AM	ADDRESS	33.9457	-118.38274	Change of lighting fixtures in the corridor and restrooms on the 8th floor of an existing high-rise building.  Load is 102A of load per applicant.  No other work on other floors on separate applications per applicant.  If addtional work is done on other floors, a full plan check for Power may be required based on the load, including the area under this application.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66825	13041-10006-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Closed	05/11/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delt 11 revisions to permitted set of plans :ADDITION OF 2 EA 40KVA/277-480V  UPS SYSTEMS; NEW CIRCUITS  AND HFC UNITS.PDP UNITS RECONNECTED DIRECTLY TO D-PCALL CHANGES ARE BUBBLED ON THE PLANSReplacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66826	15041-20001-04586	20131 W PRAIRIE ST	91311	12	198B113   121	2748038033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.2394	-118.57264	[[06-05-15 Change to  approve set of plan. Changes include addition of panel P1 to the MSB for car chargers]][[[[[TI TO AN EXSTING OFFICE COMMERCIAL BUILDING.  NEW STANDBY EQUIPMENT, PANELS, TRANSFORMERS AND CIRCUITS.  SCOPE OF WORK TO BE PERFORMED IN FIRST SECOND AND THIRD FLOOR.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 32225.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66827	11041-10000-25687	100 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Closed	11/02/2013 12:00:00 AM	PIN	33.94684048	-118.40128468	New fire alarm system for LAX Terminal 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66828	17041-20000-22037	4978 W WASHINGTON BLVD	90016	10	126B181  1048	5062004015	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.04036	-118.34854	Plan check for power and energy. TI for commercial building, change of use from board/care home to (N) office. New 600A 120/240V 1ph 3w service. T24 area - 3,605sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66829	17041-20000-28122	12255 N LIMA WAY	91342	7	219B149   932	2611046024		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.29403	-118.45585	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66830	13041-20000-18849	18000 W DEVONSHIRE ST	91330	12	204B125   310	2731020923	PF-1XL	North Valley	Northridge	Northridge East		1151.03	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM	ADDRESS	34.25313	-118.52557	existing medical offices. new lighitng and relocating. new circuits. pc for t24 energy only. total area 1038 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66831	18041-10001-35956	16850 W SAN FERNANDO MISSION BLVD ??	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.27109	-118.49964	DELTA 2 CHANGES TO APPROVED PLANS. INSTALL A NEW PANEL FOR DENTAL CHAIRS AND X-RAY.PLAN CHECK ONLY. PERMIT TO BE ISSUED DER MASTER: 18041-10000-35956<<<FULL PLAN CHECK FOR - CHANGE OF USE FROM RETAIL TO DENTAL OFFICE. T.I. REMODEL AND RESTRIPING PARKING LOT. - TOTAL AFFECTED AREA = 2056 SF. WITH APPROX. 115A OF CONNECTED LOAD>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66832	17041-10000-18222	11000 N WESCOTT AVE	91040	7	210B189   194	2551044014	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.26894	-118.3173	Installation of new roof mounted solar PV array on existing single family dwelling.  Central inverter system.  Total system size = 6 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66833	13041-10000-32735	11121 W PENDLETON ST	91352	6	198B173    45	2538011010	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.23852	-118.37336	FIRE ALARM SYSTEM; INSTALLING A SPRINKLER MONITORING SYSTEM FOR SINGLE STORY ( + MEZZANINE). FULLY SPRINKLERED SYSTEM. AREA OF WORK IS 86,721 SQ FT. WITH (7) DEVICES, AND (2) PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66834	16041-20001-38389	11319 N LOUISE AVE	91344	12	210B133    46	2711005008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM			PC Approved	11/18/2016 12:00:00 AM	ADDRESS	34.27616	-118.51121	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12.5 kWac and consists of (50) modules, (50) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66835	14041-20000-17563	15910 W VENTURA BLVD SUITE 1728	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.15561	-118.47969	PC FOR T24 ENERGY ONLY. EXISTING OFFICES. EXISTING LIGHTING. RELOCATION OF CONTROLS. PC FOR NEW CONTROLS ONLY. NEW CALCS REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66836	17041-20000-24605	15271 W LA MESA ST	91342	7	225B145   137	2501020029	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.31541	-118.46553	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.88 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66837	19041-20000-09620	8809 N ENFIELD AVE	91325	12	195B129   332	2768008006	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.23054	-118.52475	INSTALLING A 12.87KW DC/10KW AC ROOFTOP PV SYSTEM. SCOPE OF WORK INCLUDES (1) SE10000 INVERTER, AND (39) PANASONIC 330W PV MODULES WITH P400 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66838	19041-20000-47191	5623 W 77TH ST	90045	11	099B169   456	4104020016	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	02/01/2020 12:00:00 AM	ADDRESS	33.96861	-118.37953	PV1. INSTALL 9.92 KW DC PV SYSTEM WITH (31) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66839	10041-20000-06225	13949 W VENTURA BLVD 350	91423	5	165B153   438	2271014006	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.14916	-118.43708	s.350 office t.i.Energy , emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66840	18041-10000-13705	12655 W BEATRICE ST	90066	11	105B157   658	4211006017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM			Reviewed by Supervisor	06/01/2018 12:00:00 AM	ADDRESS	33.98007	-118.41764	TI AND 15,000 SQR FT ADDITION TO EXISTING WAREHOUSE BUILDING.PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66841	15041-10001-05481	600 WORLD WAY TERMINAL 6-LV.3 #622	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	CHANGES TO AN APPROVED SET OF PLANS. NOTE CHANGES IN DELTA 8. (((TI TO AN EXISITNG SINGLE STORY COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 942)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66842	13041-10000-08708	1859 W BLAKE AVE	90039	13	147A213    71	5442008034	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/04/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.09824	-118.2434	INSTALL NEW F/A SYSTEM. FIRE ALARM SYSTEM TOTAL OF 28 DEVICES, 1 FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66843	16041-30000-39571	3608 S CLARINGTON AVE	90034	5	120B165   450	4313007027	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.02665	-118.40334	Plan check for new Fire alarm system for appartment builidng. Total fire alarm devices: 16 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66844	15041-10000-38308	3425 S WESTERN AVE	90018	8	120B193   792	5041005041	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.02501	-118.30912	Full PC for a newly constructed Car wash. Installing new service: 400 amps, (3) new panels less than 400 amps. Sq Ft: 2227.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66845	19041-10000-52425	660 S FIGUEROA ST SUITE 1800	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	TENANT IMPROVEMENTS IN OFFICE SPACESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66846	12041-20002-04660	6614 W HOLLYWOOD BLVD Suite A, B	90028	13	148-5A185 130	5547015013	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM			PC Approved	09/05/2012 12:00:00 AM	ADDRESS	34.10141	-118.33371	"Lost original set of plans. Verification of original. Please look at 12041-20001-04660 as it is the ""as-built set"". Original has PCIS number 12041-20000-04660."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66847	14041-10000-19726	4832 N TUJUNGA AVE	91601	2	168B173   228	2353023019	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.1586	-118.37883	NEW 2-STORY, 5000 SF CLASSROOM BUILDINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY LIGHTING CKTADDED LOAD IS LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66848	12041-10000-15727	5841 W CARLTON WAY	90028	13	148-5A191 204	5545004010	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			07/10/2012 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.10059	-118.31725	This is a new fire alarm system, for 40 units apartment, 5 story.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66849	15041-20002-07260	19540 W LORNE ST	91335	3	189B117   228	2105004009	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM			PC Approved	05/04/2015 12:00:00 AM	ADDRESS	34.21667	-118.55957	Change to approved set of plan. Change to the layout of the modules per Inspector's request. String #1 has 13 modules and string #2 has 6 modules; Total 19 modules. **********Plan check for PV 1 roof mounted system 5kW inverter and 19 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66850	16041-10000-20366	845 E 6TH ST	90021	14	126A213   210	5147016024	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Info Complete	06/22/2016 12:00:00 AM	ADDRESS	34.04013	-118.24149	TENANT IMPROVEMENTS TO EXISTING 1 STORY BUILDING; NO CHANGE IN USE; CHANGE LAYOUT TO RECONFIGURE CLASSROOMS. PC FOR T-24 ONLY. TOTAL AREA: 3,750 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66851	18041-20000-20828	8464 N NAGLE AVE	91352	6	192B157   296	2634030006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Issued	06/05/2018 12:00:00 AM	ADDRESS	34.22499	-118.42035	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM 10.4KVA. SYSTEM CONSIST OF 2 INVERTERS(SOLIVIA 5.2 TL) AND 28 SOLARCITY MODULES WITH RAPID SHUTDOWN DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66852	12041-20000-02540	3324 N CANTON WAY	91604	2	159B169   318	2377010022	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2012 12:00:00 AM			Corrections Issued	02/02/2012 12:00:00 AM	ADDRESS	34.13318	-118.3837	New 10.8 KW P.V. system roof mounted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66853	14041-10000-17168	1865 W BLAKE AVE	90039	13	147A213    82	5442008036	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	34.09832	-118.24348	TI one story warehouse to office. New electrical service, new lighting, and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66854	15041-10001-33495	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.10311	-118.31242	Change to approved set by adding (276) fire alarm devices. original devices on the plan also being modified as a redesign plan.  Portion of the permit fee is paid under original plan, 6-story commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66855	11041-10000-23583	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			11/03/2011 12:00:00 AM	02/14/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.01303	-118.24279	TI IN AN EXISTING COMMERCIAL LOCATION.  PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66856	18041-20001-48747	3130 N BEACHWOOD DR	90068	4	157-5A191 151	5581027032	RE9-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.12681	-118.31757	Revision to approved set of plans.  Change of module from SC325 to SC330 and additional fused disconnect. Plan check only (((Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWdc/10 kWac and consists of (1) inverter, (32) modules, (2) battery back-up units, and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66857	16041-30001-18171	13631 W TERRA BELLA ST	91331	6	201B157   163	2645007006	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.2499	-118.43016	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (21) modules, (2) combiner boxes, (2) inverters, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66858	18041-10000-34848	12000 S VISTA DEL MAR Paint Shop	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Issued	09/12/2018 12:00:00 AM	PIN	33.92817449	-118.43220714	PLAN CHECK FOR TITLE 24 ONLY FOR OFFICE SPACE (Paint Shop) - TOTAL AFFECTED AREA 237 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66859	10041-20000-23841	11505 HERRICK AVE	0	7	213B157   558	2523014900	(T)R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			Verifications in Progress	05/05/2011 12:00:00 AM	PIN	34.27849534	-118.42342123	Plan check for new installation 55.44KW Photovoltaic System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66860	13041-20000-35860	5601 N DE SOTO AVE 2nd Floor	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	06/12/2014 12:00:00 AM		Permit Expired	07/25/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	Install two air handling systems, one supply and one return, and lighting for existing surgery and storage room number 2937, 2938, 2939, and 2942.  There are no receptacles work done in surgery rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66861	19041-10000-09221	10100 N CLAIRE AVE	91324	12	204B121   372	2729025005	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.25396	-118.55043	PV1. New roof mounted solar system cinsist of 31 solar panels (SANYO ElectricVBHN330SA16 330W), 31 Optimizers( SE P400)  and 1 inverter (SE11400A-US). System size 10.23 kWdc and 11.4kWac.PANEL UPGRADE TO 225A SHALL BE SEPERATELY PERMITTED. (EXPRESS PERMIT)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66862	13041-10000-22278	4501 W DON ARTURO PL	90008	8	114B177   201	5028013021	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM			Verifications in Progress	10/03/2013 12:00:00 AM	ADDRESS	34.00954	-118.354	PV1.  INSTALL 14.7 KW DC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66863	14041-10000-19282	680 W KNOX ST SUITE 200	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	33.85408	-118.28767	LIGHTING AND POWER TENANT IMPROVEMENT/REMODEL IN COMMERCIAL BUILDING. 1340 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66864	17041-20000-24707	8254 N WHITE OAK AVE ste 3	91325	12	192B129   323	2201001032	(Q)C2-1VL, C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.22073	-118.51841	ti to an existing commercial space single story.  adding new lighting new controls to new panel.  newly connected load < 400amps.  plan check for energy only.  total square footage 946.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66865	18041-10000-41054	3442 E WHITTIER BLVD	90023	14	121-5A227 167	5188017031	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Issued	10/26/2018 12:00:00 AM	ADDRESS	34.02707	-118.19974	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66866	19041-10000-16393	11300 W PEORIA ST	91352	6	198B173    34	2538011001	M1-1-CUGU, M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.24071	-118.3771	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66867	14041-10003-17723	730-736 S LOS ANGELES ST	90014	14	127-5A211 236	5145002001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			05/15/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.04254	-118.25109	CHANGES TO AN APPROVED SET OF PLANS UNDER CLOUDED PORTIONS - CHANGES INCLUDE   NEW FIREPUMP DISCONNECT.Withdrawl per customer request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66868	18041-10000-00348	2509 W 76TH ST	90043	8	099B189    51	4009015014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	33.97107	-118.32127	PC for new 7.6kW PV roofmounted system with 5kW battery backup. Installing 15 modules with optimizers and central inverter. Battery permit is under 18041-10002-00348.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66869	16041-30001-39958	1620 E 108TH ST	90059	15	088-5A213  94	6069001019	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	33.93773	-118.2454	12/13/2016 Changes to an approved set of plans. Changes have been made to the roof layout and to the MSP.*****Previous Work Description*****Plan check for PV roof mounted system SFD. System size: 3.8kW with 14 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66870	15041-20000-02780	12473 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	33.97916	-118.41034	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66871	13041-10001-33083	14824 1/2 W CHATSWORTH DR	91345	7	207B149     7	2615022***	(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.26854	-118.4556	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66872	15041-10000-05017	5629 N FIGUEROA ST	90042	1	151-5A229 230	5468033021	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.1095	-118.19335	Title 24 plan check only.  Total area = 1,285 sq. ft.Renovation of existing commercial building from retail to coffee shop.  3 new panels (<400 A connected load) + lighting and recepticles.  800 A service upgrade is NOT included in scope of work.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66873	15041-10000-24056	1500 W PACIFIC COAST HWY Bldg B	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FIRE ALARM FOR New 3-story, 5 unit apartment with garage, Typev VA construction. 23 FA DEVICES.CONTROL PANEL IN REC B WITH APP # 150141-10000-24054.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66874	17041-20000-25582	2420 S HILLCREST DR	90016	10	123B181   620	5050005045	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	PIN	34.03421899	-118.34124507	Plan check for solar pv system, roof-mounted on SFD.3.84kW ungrounded system. (24) 320W AC modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66875	16041-10000-26710	1700 E CESAR E CHAVEZ AVE STE 2100-& 2300	90033	14	130-5A221 257	5174008024	C2-1-RIO, [Q]R5-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.05093	-118.21753	Full PC for Power and Energy. Tenant Improvement of (E) medical office. Demolish existing demising wall and create one suite out of two. Scope includes relocating the lighting lighting fixtures and adding new receptacles. Total affected area is 1516 Sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66876	14041-20000-16819	1513 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.09851	-118.32696	Change of use from restaurant to beauty salon in (E) commercial tenant space.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66877	18041-10001-36010	444 S FLOWER ST Ground Flr	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM			PC Approved	04/18/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	DELTA 6 CHANGES TO AN APPROVED T-24 PLAN. CHANGES TO UPDATE THE EMERGENCY LIGHTING, CONTROLS (PS) AND SINGLE LINE DIAGRAM PER INSPECTOR REQUEST. ADDITION OF 2 SUBPANELS FOR THE SIGNAGE ILLUMINATION. TOTAL CONNECTED LOAD IS UNDER 400A. ADDITION OF A NEW COVE LIGHTING IN ELEVATOR LOBBY. T-24 RECHECK AND UPDATES ARE SUBJECT TO FIELD INSPECTION. UPDATE FIXTURE RD8 FIXTURE VOLTAGE FROM 120 TO 277. Original scope: TI IN AN EXISTING COMMERCIAL SPACE IN THE LOBBY AREA ON THE GROUND LEVEL. T-24 ENERGY ONLY.BLDG PERMIT: 18016-10000-19379	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66878	15041-10000-13885	3016 N BROADWAY	0	1	138A223    68	5208004027	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	PIN	34.07336607	-118.20943828	TI TO AN EXISTING SINGLE STORY BUILDING.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 2063.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66879	17041-20001-41017	2069 N ARGYLE AVE	90068	4	151-5A189 314	5586001046	R3-1XL	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.10874	-118.32544	expeditepv2install roof mounted pv system sized 40kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66880	19041-10001-12017	5535 E YORK BLVD	90042	14	154-5A227  10	5478025002	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.11962	-118.19698	Plan check only. CHANGES TO AN APPROVED SET TO UPDATE PLANS TO REFLECT EXISTING CONDITIONS WITH 200A SERVICE INSTEAD OF 800A. CHNAGES ALSO INCLUDE UPDATING PANEL TO 1 PHASE 3W. ALL CHANGES MARKED UNDER DELTA 1, 2 AND 3. NO CHANGES TO T-24(Original Plan check)T-24 energy only plan check for a TI to a change of use from retail space to cafe/lounge with seatings. Scope includes new panel, circuits, lighting and receptacles. total affected area is 1342 sq.ftPartial permit fees are paid under express permit # 19041-10000-07101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66881	17041-20001-35658	550 S SERRANO AVE	90020	10	135B193   820	5503021025	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.06398	-118.30642	EXPEDITED PER APPLICANTS REQUEST. PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.32 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66882	19041-20000-51473	2528 S GRAND AVE	90007	9	121-5A205 164	5126019***	(T)(Q)C2-2D-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	02/03/2021 12:00:00 AM		Permit Finaled	10/25/2023 12:00:00 AM	ADDRESS	34.02659	-118.27198	Full plan check for a 5-story, 296-unit apartment building. Scope includes a 4000-amp 277/480v service supplying (4) main distribusion section. total 33 typical unit with a total T24 lighting area of 207,486-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66883	15041-10000-35602	907 E 3RD ST	90012	14	129A215   276	5163006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	PIN	34.04608986	-118.23489239	NEW FIRE ALARM SYSTEM TO AN (E) COMMERCIAL, ART GALLERY. (112) FIRE ALARM DEVICES, 2 POWER SUPPLIES AND 1 NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66884	13041-20000-11229	970 N MONUMENT ST #102	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/06/2013 12:00:00 AM	ADDRESS	34.04646	-118.52393	Change to lighting only in suite 102, in an existing low-rise retail space.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66885	16041-20000-21977	19761 W WINGED FOOT WAY	91326	12	216B117    98	2701026015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.2879	-118.56448	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (30) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66886	13041-10001-32966	9509 N RUBIO AVE	91343	12	201B137   985	2686010***	RS-1	North Valley	Northridge	Northridge East	YES	1173.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.24339	-118.49617	Expedited RSES plan check per applicant request.[][]PV1, Install  4.24 kw DC roof-mounted solar array for a 2 story house interconnect with service panel.Transformerless inverter: SOLAREDGE SE3800-US. 16 modules: Suniva OPT265-60-4-1B0.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66887	18041-20000-29338	16501 W VENTURA BLVD Ste 510	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	01/23/2024 12:00:00 AM	ADDRESS	34.1578	-118.49275	Existing commercial office remodel.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66888	18041-10000-20486	806 E 3RD ST	90013	14	129A215   316	5163015028	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.04564	-118.23594	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP AND 84 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66889	18041-20000-36232	7053 N OWENSMOUTH AVE	91303	3	183B105   455	2138004022	P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	08/13/2020 12:00:00 AM		Permit Finaled	03/08/2023 12:00:00 AM	ADDRESS	34.19886	-118.60173	Install new 600 amp 120/240 single phase service. Provide (3) new panels, loads and lighting. Plan check for power and energy.Building permit number: 18010-20000-04225	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66890	10041-10000-21731	7298 W MANCHESTER AVE	90045	11	096B157  1066	4119026041	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	Commercial			11/01/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	11/12/2010 12:00:00 AM	ADDRESS	33.95951	-118.42211	Ti in an existing fitness. Plan check is for T24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66891	12041-10000-25608	1310 S ABBOT KINNEY BLVD	90291	11	108B145  1283	4238004015	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM			Corrections Issued	11/07/2012 12:00:00 AM	ADDRESS	33.99094	-118.46783	TI IN AN EXISTING RETAIL STORE. EPC IS FOR T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66892	16041-10002-08795	1245 W WILSHIRE BLVD STE. 630	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO LOW VOLTAGE CONTROLS INSTEAD OF LINE VOLTAGE. UTILIZING ROOM CONTROLLERS AND LOW VOLTAGE CONNECTION TO ROOM CONTROLLER.<<Added Suite number 630 to the address.  Zero fees due to Dept. error.>><PC FOR POWER AND ENERGY.  TI. FIRST TIME TENANT. MEDICAL OFFICE. TOTAL AREA 3180 SQ FT. ORIGINAL PERMIT: 10041-20003-24663>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66893	17041-20001-20547	18438 W BURBANK BLVD TEMP	91356	3	174B125   437	2160010036	[Q]C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	PIN	34.17149566	-118.53428225	Revisions to approved set of plans.  Trailer connections added to plans and permit scope.  (((Plan check for power only. TEMP power for construction trailers. Installing service, main panel, and pole mounted disconnects. Feeders are run overhead. 600A 277/480V 3ph 4w.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66894	14041-10000-07833	2716 S ELLENDALE PL	90007	9	123B197  1470	5055013025	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			03/24/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.02988	-118.28859	New methane gas detection system in a multifamily dwelling.  18 devices and one central gas detection controller.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66895	12041-20000-12367	19621 W REDWING ST	91356	3	174B117   477	2164015014	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM	ADDRESS	34.17077	-118.56083	New photovoltaic system on roof of a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66896	19041-20002-08451	7745 N JELLICO AVE	91325	12	189B129  1124	2202001011	RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM			PC Approved	04/19/2019 12:00:00 AM	ADDRESS	34.21132	-118.51754	04-19-2019 Changes to an approved set of plan, changes include relocate equipment as built design. Changes has been clouded. Plan check only. Fees $ 0.00 due to California Senate bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66897	13041-10000-05560	500 S VIRGIL AVE # 305	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	05/09/2013 12:00:00 AM	ADDRESS	34.06492	-118.28687	REMODELING DENTAL OFFICEPLAN CHK IS FOR POWER AND TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66898	12041-10000-16756	695 S VERMONT AVE	90005	10	132B197   178	5094008026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.06016	-118.29183	Plan check T24 Energy/Emergency lighting for office TI Suite  #1177. Permit for new branch ckts. Less than 400A installed. High rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66899	11041-10000-01082	533 S WESTERN AVE C	90020	4	135B193   779	5503018003	C2-1	Central	Wilshire			2117.02	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM	03/09/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.06437	-118.30928	T-24 and emergency lighting for RETAIL SPACE changed TO DINE IN RESTAURANT  (TI)  (~ 1820 SF) CHANGE OF USE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66900	14041-10000-21678	5017 S 11TH AVE	90043	8	111B185   498	5013019029	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	33.99709	-118.32962	Installation of roof mounted solar PV array.  Total system size = 3.6 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66901	17041-20000-22780	24300 W SHREWSBURY CIR	91307	12	183B089    80	2028010015	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.20094	-118.65378	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (35) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66902	17041-10000-29086	535 W EL SEGUNDO BLVD	90248	15	081B201   256	6132002022	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Apartment			08/16/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	33.91658	-118.284	PLAN CHECK FOR ROOFTOP SOLAR SYSTEM - SYSTEM SIZE(23.4KWac) CONSISTING OF 2 CENTRAL INVERTERS(SOLAREDGE SE9KUS/14.4KUS) AND 80 MODULES(HYUNDAI-S350TI) WITH 40 POWER OPTIMIZERS(P700)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66903	10041-10001-16710	1224 S BEVERWIL DR 1-12	90035	5	132A167   219	4330024036	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Approved	01/03/2011 12:00:00 AM	ADDRESS	34.0554	-118.39891	"REVISION TO THE APPROVED PLAN. REMOVE THE PAGE TITLE ""NOT FOR CONSTRUCTION"", CHANGE A SWITCH TO DIMMER, AND CLARIFYING THE LOCATION OF AN EXISTING LIGHT. ((((((((TI IN THE AN EXISTING CORIDOR AND ELEVATOR LOBY OF ""MR. C"" HOTEL ON 10 FLOORS (2ND THROUGH 11TH).  PLAN CHECK IS FOR T-24 ENERGY CALCS.  REPLACING EXISTING FIXTURTES 1:1.  EXISTING SWITCHES.))))))))))))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66904	14041-10000-34997	8051 W 3RD ST	90048	5	138B177   732	5511022016	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.07216	-118.36499	Plan check for power and energy. Full Plan check for fist time tenant  (verve coffee roasters) 1,820 SQ (Existing Core and Shell) (2) 200A panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66905	15041-10000-07138	156 S MARTEL AVE	90036	5	138B181  1127	5512015023	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	34.07193	-118.35094	PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON  DWELLING. INTERCONNECT WITH MAIN SERVICE PANEL. (8) MODULES: YINGLI YL250P-29B(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66906	14041-10000-23718	1119 N LINDA FLORA DR	90049	5	144B145   142	4368026013	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Expired	09/28/2016 12:00:00 AM	ADDRESS	34.09011	-118.46627	PV1 Standard plan, 8.925 roof-mounted system including 3K and 5k watts Solaredge inverters, (35) Trina Solar TSM -255 modules and P300 Solaredge power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66907	18041-10000-40641	111 E UNIVERSAL HOLLYWOOD DR 15,18 & 24-FLRS.	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.13855	-118.36112	PLAN CHECK FOR T-24 ONLY. RENOVATION FOR RESTROOMS IN 15TH, 18TH AND 24TH FLOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66908	14041-10000-11159	501 W EL SEGUNDO BLVD	90044	15	081B201   259	6132002020	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM			PC Approved	05/07/2014 12:00:00 AM	PIN	33.91663801	-118.28317828	PLAN CHECK FOR ENERGY ONLY FOR CHECK CASHING STORE. NOT A FIRST TIME TENANT PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66909	19041-20000-38578	23556 W HATTERAS ST	91367	3	174B093   123	2041009013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.17536	-118.64043	PV1.  Install 16.17 kW DC / 13.6 kW AC roof mounted grid tied PV system.  (49) modules with 3.6 and 10 kW rated inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66910	15041-10000-29285	11900 W OLYMPIC BLVD #100	90064	11	123B149   541	4259024003	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.03252	-118.45186	TI, PC for T-24,  to a commercial bldg (historical bldg, retail). Scope of work: installing new lighting and one new panel. Sq Ft = 4110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66911	17041-10001-38943	11911 W WESTMINSTER PL	90066	11	114B153    17	4249017020	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.01261	-118.43229	**PV expedite fee per applicantInstall new 5kW AC rooftop solar and 13.5kWh ESS on a SFD. (19) modules with (19) optimizers, (1) inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66912	13041-10002-30137	22400 W LULL ST	91304	12	186B101   106	2013019017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/15/2013 12:00:00 AM	ADDRESS	34.209	-118.61505	Expedited RSES plan check per applicant request.(((PV1, Install 6.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 27 modules: Fronius IG Plus V 7.5.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66913	16041-20000-35607	18905 W KIRKCOLM LANE	91326	12	219B121   379	2820017008	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.29316	-118.54518	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (28) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66914	13041-10000-04038	688 S BERENDO ST	90005	10	132B197   144	5094008009	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			02/15/2013 12:00:00 AM	03/22/2013 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.06036	-118.29399	PLAN CHECK FOR FIRE ALARM SYSTEM ON SIX STORY BUILDING WITH OVER 150 DEVICES AND NEW PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66915	18041-10000-47323	7945 W LULU GLEN DR	90046	4	156B173   449	5570029002	RE11-1-HCR	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	04/24/2019 12:00:00 AM	ADDRESS	34.12227	-118.37004	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.51KWdc / 11.40KWac.(41)MODULES-Q.PEAK.G4.1 305(41)OPTIMIZERS-SOLAREDGE P320W(1)INVERTER-SOLAREDGE SE11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66916	13041-20001-22442	11313 W WEDDINGTON ST	91601	2	171B173   290	2350016001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	ADDRESS	34.16711	-118.3779	NOT A MEDICAL OFFICE/CLINIC.  Modification to approved set of plans for a beauty salon.  Load is still less than 400 amps, PLAN CHECK ONLY.     <<<<Change to lighting in an 2-story existing office building.  Load is less than 400 amps per the applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66917	12041-10000-23512	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/02/2012 12:00:00 AM	03/04/2013 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN CHECK T24 ENERGY FOR LED SIGN AT TBIT DEPARTURE. LIGHTING POLE INSTALLATION EXEMPT FOR ROADWAY. SIGN STRUCTURE PERMIT APPROVED UNDER #12026-10000-00421	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66918	19041-10000-49442	2789 W OLYMPIC BLVD 101	90006	10	129B197   187	5078007033	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2133.20	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.0529	-118.29436	PLAN CHECK FOR A TI (FIRST TIME TENNANT), SCOPE OF WORK IS NEW LIGHTING AND POWER, NOTE THERE IS NO NEW PANELS, AND THE EXISTING SERVICE SIZE IS 2000A (120/208). TOTAL AFFECTED AREA IS 1712 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66919	14041-10000-33749	7939 W ELLENBOGEN ST	91040	7	210B193   322	2552038013	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.27153	-118.30618	Installation of new roof mounted solar PV array.  Total system size = 6 kWac. FEE AMOUNT REFLECT ON SENATE 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66920	15041-10001-28482	1115 W SUNSET BLVD	90012	1	136-5A211 440	5406020003	C2-2D	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.06687	-118.24925	Changes made to approved set.  Change of lighting fixtures and layout.  Plan check only for energy.  (((TI TO (E) CAFETERIA FOR OFFICE USE ONLY. NO CHANGE IN PARKING ENTERPRISE ZONE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66921	19041-20000-44260	3604 S FRANCES AVE	90066	11	114B153  1016	4246011025	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.00652	-118.43996	Plan check for PV roof mounted system, PV system size: 14.35KW DC with 41 PV Modules and 41 Microinverters connected to 2 sub-panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66922	13041-10000-13226	7600 S SEPULVEDA BLVD	90045	11	102B165   948	4106018001	[Q]C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	ADDRESS	33.97143	-118.39468	pc for energy only. less than 400A connected load. INTERIOR TENANT IMPROVEMENT FOR existing RETAIL STORE.  goodwill industries	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66923	14041-20000-20417	9932 N WOODLEY AVE	91343	12	201B141    71	2669022002	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.25128	-118.48472	New roof mounted PV system with Optimizers.  Total system size 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66924	19041-10000-24754	7405 N VAN NUYS BLVD	91405	6	186B149   389	2218004016	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.20517	-118.44975	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66925	16041-10000-40436	4551 S GLENCOE AVE #350	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	33.9844	-118.43407	PC FOR ENERGY. T.I  OFFICE. 3RD FLOOR #350. TOTAL AREA 5146 SQ FT. B # 16016-20000-24377	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66926	15041-20000-32710	508 N JUNE ST	90004	4	141B185   957	5523001024	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.08059	-118.33402	PV1. Install roof mounted PV system sized 7 kW. Interconnected with main service panel.(24) LG Monox 315 Modules(1) SMA 7.0 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66927	13041-10000-35652	1455 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.09728	-118.31598	NEW 7  ELEVATED LEVELS AND 2 BELOW GRADE PARKING STRUCTURE PLAN CHECK. PLAN CHECK FOR POWER AND ENERGY. NEW 2000A UNDERGROUND, 480/277V,3PH,4W. PROJECTED LIGHTING AREA IN SCOPE OF WORK IS APPROX. 581,525 SQ FT(INDOOR CONDITION/UNCONDITIONED + OUTDOOR ). 600A EMERGENCY DISTRIBUTION BOARD VIA 400A ATS, FED FROM 350kW/486 KVA EMERGENCY STANDBY DIESEL GENERATOR.building permit: 13010-10000-04219	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66928	19041-10000-53545	534 E BROADWAY 1-4	90291	11	108B145   550	4239020009	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Issued	12/27/2019 12:00:00 AM	ADDRESS	33.994	-118.46924	Plan check for a fire alarm system located in a 7-story, high rise building. Scope includes ( 1) fire alarm panel, (2) power supplies and (108) fire alarm devices.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66929	19041-20000-03277	12424 W WILSHIRE BLVD Suite 750	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			01/28/2019 12:00:00 AM			PC Approved	01/28/2019 12:00:00 AM	ADDRESS	34.04135	-118.47058	Plan check for Title 24 only in existing space Tenant Improvement  office space. Total area: 2059 sq ft. B#18016-10001-34786	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66930	17041-20000-32782	20722 W MALDEN ST	91306	3	192B109   156	2780032018	R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	04/04/2018 12:00:00 AM		Re-Activate Permit	11/05/2019 12:00:00 AM	ADDRESS	34.22528	-118.58493	Plan check for the addition a Tesla Powerwall to an existing PV1 roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66931	13041-20002-03123	6501 N FALLBROOK AVE	91307	3	180B097   471	2038040016	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	34.1881	-118.62368	(((PLAN CHECK FOR T24 CHANGES. CHANGE IN LIGHTING. ALL CHANGES ON SUPPLEMENTAL SET CLOUDED)))))PLAN CHECK FOR POWER AND ENERGY. ELECTRICAL WORK IS FOR NEW OLIVE GARDEN RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66932	13041-10001-29537	12790 N ADELPHIA AVE	91340	7	222B157   495	2513012029	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.3027	-118.42622	Expedited RSES plan check per applicant request. ((((PV1.  Install 7 kW DC roof-mounted solar array, interconnect with main service panel.  Inverter: Fronius IG 5100 Neg. 28 modules: Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66933	19041-10001-25036	11365 W VENTURA BLVD 1ST FLOOR	91604	2	162B173   448	2366036025	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			07/19/2019 12:00:00 AM			PC Approved	07/19/2019 12:00:00 AM	ADDRESS	34.14027	-118.37796	Plan check only.  T-24 PLAN CHECK FOR A BATHROOM REMODEL. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 700 SQ.FTPERMIT FEES ARE PAID UNDER 19041-10000-25036	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66934	10041-10000-15742	15060 W VENTURA BLVD #490	91403	5	168B145  1077	2276005036	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	09/17/2010 12:00:00 AM	ADDRESS	34.15287	-118.46147	TI IN AN EXISTING OFFICE AREA IN SUITE # 490. PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66935	19041-10001-14842	730 S SERRANO AVE 1-32	90005	10	132B193   438	5093014020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.05884	-118.30642	revision to an approved set Power check only. change under delta 2. change include updating load calculations(total and units) and updating the quantity of electric heaters and locations, less devices overall.permit fees under original applications.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66936	14041-20001-10311	10831 N HASKELL AVE	91344	12	207B141   136	2667016031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.26745	-118.4762	EXPEDITE PER APPLICANT REQUEST(((PV1Install roof-mounted solar array on SFD, interconnect with main panel.System size: 6.25kW.(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(25) Canadian Solar #CS6P-250PX pv modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66937	13041-10001-35412	9901 N WYSTONE AVE	91324	12	201B121   117	2729005018	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	01/29/2014 12:00:00 AM	ADDRESS	34.2503	-118.54723	Expedited RSES plan check per applicant request.{{PV1, Install 6.25 kw DC roof-mounted solar array, interconnect with main service for a one story house. (1)Transformerless inverter(s): SOLAREDGE SE 6000A-US, (25)Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66938	18041-20000-34515	4151 W PROSPECT AVE Bldg#25 Rm-121	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.10191	-118.28217	Plan check for Title 24 only in existing office space T.I. in room 121. Total aera: 583 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66939	14041-20000-35962	7888 N VAN NUYS BLVD 1-2	91402	6	189B149   639	2212028015	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.21514	-118.44612	Plan check for power and energy. CHG OF USE FROM TRADE SCHOOL TO RETAIL (Pet's Mart) ALSO EQUIPMENT PLATFORMS @ ROOF. Existing service, pull section, and service disconnect, all other electrical work is new.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66940	13041-10001-20337	610 S ST LOUIS ST	90023	14	126A221   122	5183023003	[Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Apartment			08/26/2014 12:00:00 AM			PC Approved	08/26/2014 12:00:00 AM	ADDRESS	34.03862	-118.21749	CHANGES TO LIGHTING SYSTEM (PLANS ARE CLOUDED TO INDICATE CHANGES)  CHANGE OF USE FROM HISTORIC HOSPITAL TO SENIOR AFFORDABLE RESIDENTIAL UNITS, WITH 96 SENIOR AFFORDABLE UNITS, AND ONE MARKET RATE TWO BEDROOM UNIT, TOTAL OF 97 UNITS.  NEW 4000A SERVICE AND DISTRIBUTION SYSTEM.  POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66941	12041-10000-29935	24068 W EAGLE MOUNTAIN ST	91304	12	193-5A089  74	2017024011	RE15-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.2253	-118.65145	PV1 SOLAR INSTALLATION IN A ONE STORY BUILDING IN STANDARD PLAN. USING 28 MODULES IN FOUR DIFFERENT STRINGS. NOT USING A COMBINER BOX. SYSTEM SIZE IS 9.156 KW. [INVERTER: SUNPOWER # SPR-8000M |||| MODULES: SUNPOWER # SPR-327NE-WHT-D]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66942	19041-10000-04185	822 S PLYMOUTH BLVD	90005	4	132B189   424	5090028007	[Q]R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			02/04/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.05909	-118.32404	INSTALLING 48 NEW FIRE ALARM DEVICES AND 1 NEW FIRE ALARM PANEL IN 4 FLOOR APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66943	16041-20000-33810	14801 W PAMPAS RICAS BLVD	90272	11	126B129   512	4411007012	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2016 12:00:00 AM	10/31/2016 12:00:00 AM		Permit Finaled	12/22/2019 12:00:00 AM	ADDRESS	34.04115	-118.51895	Plan check for power only. 800A service and distribution for new 2-story SFD w/attached garage over 1-level basement.Note: Building permit has been pulled under 15010-30000-02898. Electrical permit fees have been partially paid for under the issued building permit. Fees have been adjusted to reflect the remaining balance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66944	17041-20000-18232	11741 W PICO BLVD	90064	11	123B149   698	4260029028	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.03132	-118.44667	Plan check for fire alarm system. New fire alarm system for retail space on first floor of mixed use building. 1 FACP. 6 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66945	14041-10001-25414	1737 N LAS PALMAS AVE 1-82	90028	13	148-5A185  43	5547010004	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			10/16/2015 12:00:00 AM			PC Info Complete	10/16/2015 12:00:00 AM	ADDRESS	34.1026	-118.33639	Changes to approved set. Updated the feeder to match installed circuiting 5 EV chargers and 2 garage openers. (((New 6 story 82 unit apartment building using old codes. Building approved in 2013.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66946	11041-10000-22663	15539 W AQUA VERDE DR	90077	5	156B141    60	4378032013	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	12/30/2011 12:00:00 AM	ADDRESS	34.12295	-118.47365	New 25 kva rooftop photovoltaic system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66947	14041-20000-32780	14948 W ALTATA DR	90272	11	123B129   663	4411024020	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.03183	-118.5213	FEE IS $0.00 DUE TO 2012 CA STATE SENATE BILL 1222.PV1 SFD. TOTAL SYSTEM SIZE 18KW DC/ 16KW AC USING A COMBINATION OF 2 CENTRAL INVERTER SYSTEMS AND A STRING OF MICROINVERTERS. USING ENPHASE M250 FOR THE MICROINVERTER. SYSTEM CONNECTS TO (E)600A SERVICE. 1PH-3W 120/240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66948	13041-10000-32796	9301 N TAMPA AVE # 193	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			11/22/2013 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Interior remodeling to convert stock room into retail store.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66949	10041-20000-05550	20931 W BURBANK BLVD	91367	3	174B109   309	2149017013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Finaled	05/18/2010 12:00:00 AM	ADDRESS	34.1735	-118.58886	installing lighting fixtures inside office spaces and egress lighting in hall way in commercial place. This plan check is title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66950	15041-20002-07468	759 N SPRING ST	90012	1	133-5A215  38	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM			PC Approved	02/01/2017 12:00:00 AM	PIN	34.06161992	-118.23745547	02/01/2017 - Changes to approved set of plans.  Change of engineer for redesign of exterior lighting system.  Plan check for power and energy.  {{{{{{Plan check for power and energy , work is on second and third floor. Inspector to verify routing of SEC. Changes on plan include updates to T24, Emergency lighting added for 2nd floor and put on general circuit, and lockon where exception used for unit equipment.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66951	13041-10000-24755	2508 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.0334	-118.2974	PV1. INSTALL 2.94 KW DC ROOF MOUNTED SOLAR ARRAY OF 12 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66952	18041-10000-29632	6626 S 10TH AVE	90043	8	102B185   126	4006013002	MR1-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	05/21/2020 12:00:00 AM	PIN	33.97882389	-118.32752771	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66953	13041-10000-24104	2920-2930 W ROWENA AVE BLDG 3	90039	4	151-5A205 201	5434035009	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			09/04/2013 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.10823	-118.26884	CONSTRUCTION OF NEW TOWN HOUSES, PLAN CHECK FOR POWER BUILDING 3 OF 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66954	15041-10001-22722	18559 W VANOWEN ST	91335	3	183B121  1129	2126023003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM			PC Approved	03/29/2016 12:00:00 AM	ADDRESS	34.19399	-118.53812	PC ONLY FOR NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(19)MODULES-SPR-SUNPOWER327NE-WHT-D(2)INVERTERS-SUNNYBOY SMA SB3000TL-US-22NOTE: CLEARANCE AND PERMIT PAID UNDER APPLICATION PCIS#15041-90000-22722 ((((((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66955	14041-20000-28559	435 N AVENUE 51	90042	1	151-5A225  31	5469016009	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	11/04/2014 12:00:00 AM	ADDRESS	34.11121	-118.20409	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW(1) SolarEdge SE3800A-US transformerless inverter(17) SolarEdge P300 power optimizers(17) Renesola JC250M-24/BB pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66956	18041-10001-20618	8530 N BALBOA BLVD	91325	12	192B133    87	2689019011	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	34.22605	-118.50242	"DELTA 2 CHANGES TO APPROVED PLANS FOR DESIGNATING 9 OF 12 EV CHARGERS TO ""FUTURE"". <<<<PLANCHECK FOR POWER ONLY. ADDITION OF EV CHARGERS. PART 2 OF 2. PLANCEHCK DUE TO APPLICANTS REQUEST. EV CHARGERS INSTALLED IN TWO BUILDINGS. MAIN BUILDING IS 8510 N BALBOA ( 18041-10000-20615)>>>>>BUILDING PERMIT # 18020-10000-00234"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66957	11041-10000-20700	3460 W 7TH ST	90005	10	132B193   388	5093025028	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Apartment			10/18/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.05958	-118.3025	CONVERSION OF 168 APARTMENTS IN AN EXISTING 13-STORY BUILDING TO 168 CONDOMINIUMS IN CONFORMANCE WITH VTTM 64165-CC-1A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66958	19041-10000-52352	544 S TOWNE AVE	90013	14	127-5A213 541	5147020011	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.04186	-118.24281	PLAN CHECK FOR POWER. NEW 400A SERVICE FOR A HOMELESS SHELTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66959	16041-10000-06433	1800 S AVENUE OF THE STARS PK, D, & F-LEVEL	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	34.06095	-118.41786	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS FOR 3 PARKING LEVELS (PK,D&F) AND WAITING LOBBY AREA. TOTAL AFFECTED AREA IS 9255 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66960	13041-10000-11134	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC FOR ENERGY. TI TO EXISTING BUILDING. Sanrio Smiles #73 Permit under 13041-10001-09646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66961	17041-20002-09874	12601 W PIERCE ST BLDG 43	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (building 43).2.5kW ungrounded system. (5) AP Systems YC500i microinverters. (10) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66962	17041-20000-14091	13790 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM			PC Approved	04/28/2017 12:00:00 AM	ADDRESS	34.30953	-118.43339	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,549 sq. ft.Note: Building application has been generated under 17016-20000-10197	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66963	14041-20000-12389	10574 W OHIO AVE	90024	5	132B157   531	4326022007	R1-1-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.05818	-118.43144	Roof mounted PV system with Enphase microinverter, model M215-60-2LL-, System size 2.16KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66964	12041-10000-25395	701 W CESAR E CHAVEZ AVE #109	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural		2071.01	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.06107	-118.24412	TI WORK EXISTING RESTAURANT TO TAKE OUT RESTAURANT;  CHANGE THE UNIT NUMBER FROM 108 T0 109 PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66965	17041-10000-43431	950 N WESTERN AVE	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	33.75127	-118.3088	Minor tenant remodel of existing CVS store not involving changes to the lighting system. Electrical permit was obtained on application 17041-10000-42228. Plan required by Electrical Inspector	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66966	12041-10001-10166	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/29/2013 12:00:00 AM			PC Approved	07/29/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	(((CHANGES TO APPROVED SET:  MOVED TRACK LIGHTING)))Change to lighting at ticket counter and for artwork display at Terminal #3 at LAX.  (Ticketing Area).  Load is 42A and occupancy load is 98, per applicant.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66967	19041-10000-17677	230 E 1ST ST	90012	14	130-5A213 117	5161016008	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	10/06/2021 12:00:00 AM	ADDRESS	34.05074	-118.24176	T-24 PLAN CHECK FOR A TI OF AN EXISTING STORE (CHANGE OF USE FROM STORE TO MODEL SHOWROOM FOR APARTMENTS SALE). SCOPE INCLUDES NEW 125A PANEL , EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 1972 SQ.FTB# 19016-10000-15147	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66968	17041-10000-33774	20430 W MARILLA ST	91311	12	201B109   205	2748013035	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.24712	-118.57826	PC FOR PV SYSTEM. USING 14 MODULES TOTAL WITH CENTRAL INVERTER 3KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66969	12041-10000-02277	127 S SAN VICENTE BLVD Bulletin-83.1CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/31/2012 12:00:00 AM			PC Approved	01/31/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	REVISION Delta # 83.1CS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66970	17041-20001-28111	334 S CATALINA ST	90020	10	135B197   370	5502006023	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.06802	-118.29526	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 18.2 kWac and consists of (2) inverters, (66) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66971	18041-20000-36968	20600 W BERGAMO WAY	91326	12	213B109   122	2701052008	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.27627	-118.58195	Installation of 19.6 kWh energy storage system connected to (E) 7.6 kW rated inverter with energy storage capabilities.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66972	17041-10000-24800	3533 E SABINA ST	90023	14	121-5A227  35	5188003031	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.0284	-118.19606	PC FOR ROOF MOUNTED PV ON SFD. SYS. SIZE 3.0KW/AC10 MODULES WITH OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66973	15041-20000-24291	668 S CATALINA ST	90005	10	132B197    85	5094007016	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	PIN	34.06107288	-118.2950451	Plan check for Service upgrade 1,600A with new distribution equipment. Project is located in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66974	17041-10001-06470	19800 S VERMONT AVE	90502	15	057B197    54	7351033039	[Q]C4-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Approved	05/01/2017 12:00:00 AM	ADDRESS	33.85122	-118.29031	EXPEDITE FEESPV2 COMMERCIAL CARPORT PV SYSTEM. TOTAL OF 963 MODULES AND 11 CENTRAL INVERTERS. CONNECTING TO EXISTING BUILDING MAIN SWITCHGEAR. SYSTEM SIZE 313KW DC/ 273KW ACSYSTEM USES POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66975	11041-20001-27518	2921 W LOS FELIZ BLVD Bldg F	90039	13	157-5A207 376	5594006024	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	08/07/2012 12:00:00 AM	ADDRESS	34.12622	-118.26388	Lost original approved plans.  Resubmit for plan check. *****Existing restaurant space (Building F) being occupied by a new tenant (Soup Plantation).  Adding 6 new panels and new circuits.  Full plan check.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66976	16041-20000-32792	1581 W L ST	90744	15	033B201    66	7412010903	OS-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	33.78625	-118.28634	PV2.  Solar Feed-in-Tariff project.  Installation of 101.79 kW DC ground-mount ballasted PV system.  (351) modules with (9) transformerless 10 kW rated central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66977	19041-20000-53133	19809 W PRAIRIE ST	91311	12	198B113   115	2761040023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	04/29/2020 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.23925	-118.56529	PC FOR ENERGY ONLY, SCOPE OF WORK  INCLUDES NEW LIGHTING AND RECEPTACLE LOADS. TOTAL SQ. FT. 6605.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66978	18041-10000-16177	5720 S 2ND AVE	90043	8	108B189  1029	5005005901	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	02/01/2021 12:00:00 AM	ADDRESS	33.99083	-118.31908	FULL PC FOR POWER AND ENERGY FOR A NEW BATHHOUSE. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. NEW CONNECTED LOAD > 400A. TOTAL AFFECTED AREA IS 88367 SQ. FT. B#17010-10000-01996	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66979	16041-20001-14403	17150 W NANETTE ST	91344	12	222B133   635	2602019057	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM			PC Approved	05/25/2016 12:00:00 AM	ADDRESS	34.30167	-118.50599	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(41) LG NEON MODULES(41) POWER OPTIMIZERS(1) SOLAREDGE INVERTER 11400W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66980	19041-20000-46613	3519 W 6TH ST	90020	10	135B197   996	5502019019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.02	Electrical	Electrical	Commercial			11/13/2019 12:00:00 AM	03/26/2020 12:00:00 AM		Permit Finaled	05/11/2021 12:00:00 AM	ADDRESS	34.0637	-118.29854	Distribution, power, and lighting for existing commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66981	14041-10000-07569	11300 S MONITOR AVE	90059	15	087A215   240	6069003906	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	33.93197	-118.24008	oUT DOOR TITLE 24 FOR REC AND PARKS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66982	11041-20000-25352	990 W 190TH ST s.600	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			PC Approved	11/29/2011 12:00:00 AM	ADDRESS	33.85813	-118.29505	s.600 t.i.Energy, emergency, exit signsFre Life Safety is by others 11041-10000-21654	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66983	10041-10001-25103	13275 N GOLDEN STATE RD	91342	7	225B141  1516	2604002059	(Q)M1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	PIN	34.31226914	-118.48573073	New installation of a gas tank and a diesel tank along with 3 pumps.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66984	15041-20000-31342	8455 N WHITE OAK AVE	91325	12	192B129   152	2787010019	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Expired	11/20/2017 12:00:00 AM	ADDRESS	34.22408	-118.52	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 12 kWac.  Two inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66985	19041-20000-43208	2049 S CENTURY PARK EAST 27TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Issued	10/25/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 energy only, lighting,newly connected load less than 400A. Total area: 23187 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66986	16041-10000-08419	11100 W SANTA MONICA BLVD STE 150	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.04726	-118.44465	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON SUITE 150. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES FOR CONFERENCE/RESTROOM SPACES. TOTAL AFFECTED AREA IS 1588 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66987	13041-20000-29019	5555 W MELROSE AVE SECOND FLR	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.08363	-118.32191	T24 FOR EXISTING NON HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON THE SECOND FLOOR. RETROFITTING LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66988	16041-10000-30460	5222 S HOOPER AVE	90011	9	108B209   212	5104005028	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.20	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	33.9952	-118.25193	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES.TOTAL AREA (OUTDOOR) 17277 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66989	18041-10001-12451	718 S HILL ST	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	04/03/2024 12:00:00 AM	ADDRESS	34.04527	-118.25477	Change to approved set by adding lighting ckts on the floor plan. all changes under delta-I only.(((PLANCHECK FOR POWER AND ENERGY. CORE AND SHELL RENOVATION FOR THE EXISTING 7-STORY BUILDING .BUILDING PERMIT: 18016-10000-03643)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
66990	10041-10003-18263	6150 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/01/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	33.94474	-118.39224	"MODIFICATION TO PREVIOUSLY APPROVED SET.  CHANGE OF SUBSTATION AND ADDITION OF 3 WATER HEATERS.  <<<<<<TI IN AN EXISTING OFFICE AREA AND HANGER AT LAX FOR ""RATHEON"" (ADJACENT TO DELTA HANGER).  PLAN CHECK IS FOR POWER AND ENERGY.>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66991	13041-10000-26504	24917 N BAYPOINT AVE	90744	15	039B209   293	7404026019	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	10/23/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	33.79972	-118.26022	PV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE: 8.25 KW.(33) RENESOLA SOLAR MODULES(2) SOLAR EDGE SB3800A INVERTERUPGRADE TO 200 AMP PANEL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66992	16041-20002-16867	8400-8420 N BALBOA BLVD WEST	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	ADDRESS	34.22376	-118.50243	[[12/1/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA (A) CHANGES ARE CLOUDED. CHANGING FEEDER MSB-1 AND MSB-2]]]]NEW single story Commercial build. 1600A UGPS ( None Methane Zone per Zimas). PC for Power and Energy. Total area: 495 sq.ft. (indoor) + 210,020 sq.ft. (outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66993	13041-10000-35505	15801 W MOORPARK ST	91436	5	168B141   508	2261012016	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Apartment			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/23/2014 12:00:00 AM	ADDRESS	34.15688	-118.47729	PV1, Install 4.75 kW DC roof-mounted solar array for a two story house, interconnect with main service panel.(1) Transformerless inverter(1): Solaredge SE 5000A-US. (19) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
66994	17041-20000-17645	3616 S TROUSDALE PKWY B43	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	08/11/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.01983	-118.28534	Plan check for energy only. TI to existing seawater lab, room B43. New lighting. 435sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66995	18041-20000-25702	1543 W 12TH ST	90015	1	129A203   380	5137025012	R4-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Apartment			07/10/2018 12:00:00 AM			PC Info Complete	07/29/2019 12:00:00 AM	ADDRESS	34.0461	-118.2755	Plan check for power and energy for APT 18 units 4 story building. Total area: 29,000 sq ft. B#18041-20000-02449	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66996	16041-20001-23075	5665 N RHODES AVE	91607	2	174B165   492	2340017014	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM			PC Approved	09/16/2016 12:00:00 AM	ADDRESS	34.17399	-118.40322	RSES expedited plan check fee.  PV1.  Install 15.04 kW roof mounted PV system.  (46) modules, (1) transformerless 11.4 kW inverter, (1) 5 kW inverter, and power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
66997	17041-10000-20060	500 S FIGUEROA ST	90071	14	130-5A209 117	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Closed	06/12/2018 12:00:00 AM	ADDRESS	34.05146	-118.25758	Installation of new fire alarm system for T.I. in existing LAFC ancillary building.  Total system size = 69 devices + 2 RPS + 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
66998	14041-20000-13267	8861 N WINNETKA AVE	91306	3	195B113    98	2781031006	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.23155	-118.57125	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 864 WATTS. USING ENPHASE M215. USING MICROINVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
66999	11041-10003-27553	1534 N MCCADDEN PL	90028	13	147A185    20	5547020031	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM			PC Approved	01/30/2019 12:00:00 AM	ADDRESS	34.09903	-118.33746	1/30/19PC ONLY. CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES IN CLOUDED AREAS. SCOPE OF WORK INCLUDES FULLY RATED SYSTEM TO SERIES RATED SYSTEM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67000	15041-20003-01901	5959 W FRANKLIN AVE	90068	4	150A191   161	5586014027	R3-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			05/11/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	PIN	34.1055012	-118.31956142	Plan check only.  Changes to approved set.  Transformer secondary disconnect added.  Revisions to feeder schedule.  Approval for delta-3 revisions only.  (((PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT TO 49 APARTMENT UNITS. NEW 800 SERVICE, PANEL UPGRADES, NEW CKTS AND NEW HEAT PUMPS FOR EVERY UNIT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67001	17041-20000-31399	6842 N VAN NUYS BLVD	91405	6	183B149   647	2217009011	C2-1L, PB-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM			PC Approved	09/01/2017 12:00:00 AM	ADDRESS	34.19499	-118.44846	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from office and restaurant to educational/tenant improvement. Total lighting area = 8,014 sq. ft.Note: Building application has been generated under 17016-20000-25477	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67002	15041-20000-13561	10817 W SHERMAN WAY	91352	2	183B173    89	2410019044	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			05/05/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.20136	-118.36644	Title 24 plan check only.  Total area = 2,575 sq. ft.  T.I. to existing low rise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67003	16041-10000-18675	5834 S MCCONNELL AVE	90094	11	102B161  1270	4211037202	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Issued	05/27/2016 12:00:00 AM	ADDRESS	33.97494	-118.41657	Installation of a new fire alarm system to apartment condos.2 FA panel,  1 Commnication Panel, 46 FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67004	11041-20000-10377	400 N LA BREA AVE	90036	5	138B181    62	5525029012	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM			PC Approved	05/20/2011 12:00:00 AM	ADDRESS	34.07848	-118.34385	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67005	18041-10000-00103	575 W O'FARRELL ST	90731	15	018B197   597	7448029030	R2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.7459	-118.28946	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 15725 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67006	14041-10000-00128	1212 S SAN PEDRO ST STE # C-2	90021	14	124-5A211 340	5132012003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	PIN	34.03317186	-118.25323235	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 494 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67007	16041-10000-28376	811 W WILSHIRE BLVD FLR 3	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	T-24, PC FOR ENERGY ONLY. INTERIOR TI (13,342 SF) FOR LA TSC-702 INCLUDING NEW NON-STRUCTURAL PARTITIONS AND NEW CEILING GRID & TILES IN AN EXISTING TYPE-I BLDG, INCLUDING NEW ASSEMBLY AREA TRAINING ROOMS (3601 SF TOTAL). TOTAL AFFECTED AREA IS 14070 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67008	11041-10000-13061	2600 N NORTH MAIN ST	90031	1	135A221    29	5210005031	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Approved	06/28/2011 12:00:00 AM	ADDRESS	34.06584	-118.21494	REPLACEMENT OF LIGHTING FIXTURES FROM FLOURESCENT TO LED, ONE-FOR-ONE.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67009	18041-20000-47110	1880 S CENTURY PARK EAST 300/340-350	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Issued	12/12/2018 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only in existing high-rise building retrofit existing lighting T.I. Total area: 3329 sq ft.  B#18016-10000-38723	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67010	16041-20000-23711	500 WORLD WAY Terminal 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	33.94248	-118.40461	Plan check Title 24 only Dog Relief Areas in Terminal 5 departure level by waiting area next to TSA. Total area: 88 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67011	18041-10001-11613	3321 S LA CIENEGA BLVD	90016	10	120B173   176	4205033007	(T)(Q)C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.0275	-118.3723	PC FOR POWER ONLY, CHANGES TO APPROVED SET, 1 NEW CRANE, 1 NEW PANEL, ALL CHANGES ARE CLOUDED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67012	14041-10000-14308	11674 W SANTA MONICA BLVD	90025	11	126B149   285	4262008018	(T)(Q)C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM			Reviewed by Supervisor	09/16/2014 12:00:00 AM	ADDRESS	34.04379	-118.45551	PV3, INSTALL 336.7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SAFEWAY BUILDING, INTERCONNECT WITH MAIN SSERVICE PANEL. 1104 MODULES, 14 INVERTERS. 20 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67013	12041-10000-24910	7920 W 3RD ST	90048	5	138B177   789	5511027025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM	11/30/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.07145	-118.36218	TI IN AN EXISTING COMMERCIAL SPACE. (ICECREAM SHOP). PLAN CHECK FOR TITLE-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67014	17041-20000-34062	9937 N SHOSHONE AVE	91325	12	201B129    26	2734020003	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	PIN	34.25147359	-118.51747096	Plan check for solar pv system, roof-mounted array on SFD.5kW ungrounded system. (16) 315W pv modules.Each module has a 400W power optimizer.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67015	19041-20000-19187	4926 N ENCINO AVE	91316	5	168B129   105	2290004026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.16013	-118.51402	addition of (2) tesla powerwalls ESS rated at 5KW each to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67016	10041-10000-18702	12238 W SANTA MONICA BLVD	90025	11	126B145   839	4263037008	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	11/10/2010 12:00:00 AM	ADDRESS	34.03961	-118.46496	TENANT IMPROVEMENT IN EXISTING BAR/RESTAURANT AND EXTERIOR LIGHTINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67017	15041-20000-09463	911 N AVENUE 64	90042	14	156A233   177	5486028013	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.12238	-118.17719	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system with three branch circuits.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67018	14041-20001-05190	19350 W NORDHOFF WAY	91324	12	195B117    14	2783028056	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.23523	-118.55518	((changes to approved set of plans. this is plan check only for new energy calcs. T24 FOR EXISTING RESTAURANT. OCCUPANT LOAD DOES NOT EXCEED 100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67019	14041-10000-32994	200 WORLD WAY DUTY FREE-SHOP	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	TENANT IMPROVEMANT ON EXISTING SHELL SPACES 237 & 222 FOR DUTY FREE STORES.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67020	14041-10000-31727	5553 W HOLLYWOOD BLVD	90028	13	148-5A193 134	5544003049	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.1019	-118.31108	PROPOSED INTERIOR TENANT IMPROVEMENT TO (E) RETAIL SPACE.   NO CHANGE OF USE.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67021	17041-10000-44915	1875 CENTURY PARK EAST 11TH FLR	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	PIN	34.06084104	-118.41471001	PC for T24 only for new lighting in corridor, elevator lobby and restroom on 11th floor. Removing existing LED (F5) strip lights in restoom. Total area is 1445sqft. B# 17016-10000-35702	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67022	19041-20000-16234	13711 W WEDDINGTON ST	91401	4	171B157   232	2247016026	RA-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.16679	-118.43176	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 17.82KW DC/16.3KW AC CEC/15.2 KW AC. SCOPE OF WORK INCLUDES (54) HANWHA Q CELL PV MODULES WITH P505 OPTIMIZERS, (2) SE7600 INVERTERS, AND A 100A PV LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67023	11041-20000-15854	4121 E VALLEY BLVD	90032	14	135A227    12	5215001019	[Q]CM-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Approved	07/28/2011 12:00:00 AM	ADDRESS	34.06436	-118.19504	PARKING LOT LIGHTING FOR USC. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67024	17041-10000-22919	1930 W MILAN PL	90732	15	015B189   150	7559029003	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Expired	10/03/2023 12:00:00 AM	ADDRESS	33.73799	-118.31793	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES INSTALLATION OF 16 MODULES WITH POWER OPTIMIZERS AND SINGLE INVERTER. SYS. SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67025	13041-10001-18415	8162 W MELROSE AVE	90048	5	141B173   462	5528011003	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	PIN	34.08346258	-118.36739586	SUPPLEMENTAL PLAN CHECK TO APP # 13041-10000-18415 PLAN CHECK FOR T24 ENERGY DELTA 2 CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67026	13041-20000-01249	1609 N MAGNETIC TER	90069	5	147B169   322	5561013022	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2013 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	09/02/2017 12:00:00 AM	ADDRESS	34.10018	-118.39177	Phkotovoltaic systm on roof of single family dwelling with subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67027	17041-20000-44071	16111 W MEADOW VIEW DR	91436	5	165B141   561	2285014033	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.15014	-118.48406	0$ permit fees due to senate bill 1222Plan check for solar pv system w/roof-mounted array for SFD.14.08kW ungrounded system. (44) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67028	19041-20000-27458	15006 W KESWICK ST	91405	6	186B149    15	2209038043	[T][Q]CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	09/24/2020 12:00:00 AM	PIN	34.21001028	-118.4588231	New 600A 480Y/277V service, distribution, power and lighting for new building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67029	17041-30001-08124	12900 W VANOWEN ST	91605	2	180B161    77	2326001031	C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.19373	-118.41424	07/15/2017 Changes to an approved set of plans. Changes have been made to reflect field conditions. Changes were made to the single line diagram and load circuiting. All changes have been reflected onto the floor plans. *****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,035 sq. ft. Submitted per applicant request.Note: Building application has been generated under 16016-20000-25220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67030	15041-20000-00673	2417 N GRIFFIN AVE	90031	1	138A223    14	5204021008	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/20/2015 12:00:00 AM		Permit Expired	02/13/2017 12:00:00 AM	ADDRESS	34.07438	-118.21193	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system.12  327W pv modules across two strings (6+6).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67031	15041-10000-20023	7300 N HILLSVIEW CT	91304	12	186B089   525	2027047005	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Expired	07/20/2017 12:00:00 AM	PIN	34.20449985	-118.65107276	Standard plan for PV1 roof-mounted system with (30) TSM-255 modules, (1) Sunny Boy 7000-TL inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67032	18041-10000-00358	5930 W PICO BLVD	90035	10	129B173   402	5068012046	C4-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.05176	-118.36888	PC FOR TI of existing restaurant (McDonald) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL LIGHTS AND RECETACLES. MOST ELECTRICAL SYSTEM REMAINS THE SAME. TOTAL AFFECTED AREA  7448 sq.ft (indoor & outdoor)b# 17016-10000-32275	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67033	16041-10000-31416	301 W WESTMONT DR	90731	15	024B197   541	7412026***	[Q]M2-1VL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	33.7634	-118.28753	* Zero permit fee per California Senate Bill 1222PV FOR ROOF MOUNTED PV SYSTEM. TOTAL SYSTEM SIZE 1920 kWAC USING 80KW INVERTERS - TOTAL OF 24. ALSO USING 6048 PV MODULESPV SYSTEM IS FEED IN TARRIF. INTERCONNECTION IS DIRECTLY TO UTILITY. PV ONLY SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67034	14041-20000-26183	23839 W SYLVAN ST	91367	3	177B089   105	2033019001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Expired	10/31/2016 12:00:00 AM	ADDRESS	34.18437	-118.64601	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.0KW INTERCONNETED WITH MSP.(28) KYOCERA KD255GX MODULES(28) POWER OPTIMIZERS (1) SOLAR EDGE SE6000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67035	19041-20000-08184	1640 E MARENGO ST suite b-200	90033	14	133-5A223  37	5201001001	C4-1-CUGU, P-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2033.00	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM			Reviewed by Supervisor	03/22/2019 12:00:00 AM	ADDRESS	34.05983	-118.21397	ti to an existing medical office addinge new lighting new controls to new panels.  plan check for power and energy.building application number 18016-10000-36443	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67036	17041-30003-20492	1915-1919 S LINCOLN BLVD	90291	11	108B149   119	4241024028	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.99575	-118.45666	04/03/2018 Changes to an approved set of plans. Scope of work has been increased to include both retail spaces. Total lighting area is now 1,813 sq. ft. There has been a change of engineer.*****Previous Work Description*****Plan check for Title 24 only in existing space retail. T.I. Total area: 400 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67037	12041-10000-03478	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	33.79173	-118.23549	Install 60 KVA UPS equipment at HBD bldg.  to supply loads at separate CRU-2 bldg. Feeder from HBD to CRU-2 is installed on cable tray, ~1400 ft.length between the (2) bldgs. in free air. Classified locations are exist. along the cable tray route.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67038	17041-10000-42642	1107 S ALVARADO ST	90006	1	130-5A201 307	5136018020	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Issued	11/28/2017 12:00:00 AM	ADDRESS	34.05001	-118.28118	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67039	19041-10001-28563	9300 N BALCOM AVE	91325	12	198B129   251	2766006002	RA-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.23917	-118.52141	Expedite per applicant requestNEW ROOFTOP SOLAR SYSTEM CONSIST OF 63 MODULES (Q-CELL 305) , 63 OPTIMIZER (SE P320) AND 2 CENTRAL INVERTER (SE7600H-US EACH). SYSTEM SIZE IS 19.215KWdc and 15.2KWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67040	13041-10000-12363	3756 S BEETHOVEN ST	90066	11	111B153   546	4245017018	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2013 12:00:00 AM	05/13/2013 12:00:00 AM		Permit Expired	06/08/2015 12:00:00 AM	ADDRESS	34.00116	-118.44208	PERMIT IS FOR THE DIFFERENCE OF 4 MODULES. PARTIAL PERMIT PULLED UNDER APPLICATION NUMBER 13041-20000-10251.***************************************** PV1 ROOF MOUNTED SOLAR INSTALLATION IN A SFD. SYSTEM SIZE IS 3.19KW USING POWER OPTIMIZERS. 1 STRING OF 13 MODULES AND A SINGLE INVERTER. [INVERTER: SOLAREDGE # SE3000A-US |||| MODULES: TRINA SOLAR # TSM-245PC05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67041	16041-20002-01924	11260 W MISSISSIPPI AVE	90025	11	126B153   840	4260001069	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			05/03/2018 12:00:00 AM			PC Approved	05/03/2018 12:00:00 AM	ADDRESS	34.03984	-118.44175	Plan check only for revisions to lighting design and emergency egress lighting.  (((Full plan check for a New 3-story, 17-unit apartment building (1200A, 120/240V service) with roof deck over 1-level type I-A parking structure. Total area is 9305 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67042	16041-10000-38592	1735 S SANTA FE AVE	90021	14	120A217    40	5167010013	M3-1-S-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.02426	-118.23022	PC for energy only. Outdoor title 24. Installing new lighting only. Total sqft = 39200.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67043	19041-20000-20090	2049 S CENTURY PARK EAST 39TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI to (E) commercial office space in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67044	11041-20003-20573	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Approved	01/12/2012 12:00:00 AM	ADDRESS	33.78734	-118.29768	"Changes from previously approved plans.   Changes include replace outdoor light at ""trailer"" area.  Plan check for energy only.Note: Permit is on the original application.*****Open parking lot.  Replacing the light post and light fixtures in the open lot.  Plan check is for energy only.*****"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67045	11041-10000-11551	10250 W CONSTELLATION BLVD 35th floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2011 12:00:00 AM			PC Approved	06/06/2011 12:00:00 AM	ADDRESS	34.05735	-118.41746	Ti in an existing offices. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67046	16041-10001-40350	302 N LAVETA TER	90026	1	135A209    32	5160003008	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	05/15/2017 12:00:00 AM	ADDRESS	34.06578	-118.26009	PC FOR CHANGES TO APPROVED SET TO REFLECT CHANGES ON FIELD.SCOPE INCLUDES CHANGING FIXTURE TYPE (REGULAR AND EMERGENCY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67047	12041-10001-30849	545 S FIGUEROA ST LV 1 SP 2	90071	14	130-5A209 111	5151022001	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2013 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.0514	-118.2582	changes to approved set of plans.  lighting in space is being changed to be predominantly LED except the basement and the stairs where strip flourescents will remain. no change to emergency lighting.BB6187 Jonathan Club. men's clothing store.T.I. OF RETAIL SPACE. APPLICATION FOR T24. FIRST FLOOR OF HIGH RISE. 13 FLOORS.RETAIL SPACE 2. 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67048	11041-10000-23679	808 S WALL ST	90014	14	126A211   205	5145010027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			Reviewed by Supervisor	11/15/2011 12:00:00 AM	ADDRESS	34.03982	-118.25056	Addition of new Emergency lighting to stories 2-8 of an 8 story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67049	12041-10000-12464	735 S FIGUEROA ST SPACE #-123	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	TENANT IMPROVEMENT OF NEW OLEEGO KOREAN BARBEQUE IN EXISTING INTERIOR FOOD COURT ; Occupancy load is 4 and load is 102 Amps, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67050	17041-20001-32564	9721 N WORNOM AVE	91040	7	201B181   213	2544001027	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM			Reviewed by Supervisor	09/19/2017 12:00:00 AM	ADDRESS	34.24632	-118.35212	Expedited plan check fee. PV1.,  Install 6.5 kW roof mounted grid tied PV system.  (20) modules with (1) 6 kW rated string inverter with power optimizers.  13.5 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67051	14041-10000-02789	14702 W PLUMMER ST	91402	6	198B149    61	2650031001	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.24255	-118.45386	PV1, Install 5.5 KW DC roof-mounted solar array on a two story home, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U. (22) Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67052	14041-10000-31904	13237 N GLADSTONE AVE	91342	7	225B157   672	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.31154	-118.42954	Installation of new fire alarm system to an existing commercial space.  Total system size = 39 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67053	16041-10000-05390	5700 N CANOGA AVE 1ST FLR	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.17365	-118.59715	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON THE 1ST FLOOR (OFFICE SPACE). SCOPE INCLUDEW NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10,000 SQ FEET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67054	15041-20000-10030	12465 W OSPREY LANE UNIT 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	33.97923	-118.41018	Plan check for PV roof mounted system for tri-plex unit #2 with system size: 3kW. PV clearance shall be relevent to Permit # 15041-20000-10020	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67055	12041-10000-20980	225 S GRAND AVE	90012	14	132A211    60	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Apartment			09/05/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Closed	06/01/2015 12:00:00 AM	ADDRESS	34.05388	-118.25078	PLAN CHECK FOR CONSTRUCTION TEMP POWER FOR NEW HIGHRISE MIXED USE APARTMENT & COMMERCIAL (RESTAURANT) BUILDING OVER PRIVATE PARKING GARAGE. 22 STORIES W/ 1 LEVEL BASEMENT. SITE IN METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67056	19041-10000-27508	127 S SAN VICENTE BLVD 9TH	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.07457	-118.37864	Replacing existing corridor fluorescent lights with new led lights on the 9th floor of a medical office building. T-24 only. Emergency wiring and location are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67057	13041-10000-12217	932 N ALFRED ST	90069	5	144B173   262	5529002040	[Q]R3-1	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Apartment			05/10/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.08806	-118.37515	FA NEW 8 UNIT APT. 4 STORIES OVER BSMT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67058	16041-20000-30874	6585 W SANTA MONICA BLVD	90038	13	144B185   715	5533011001	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.09086	-118.33291	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement/change of use from retail to vet clinic. Total lighting area = 5,830 sq. ft.Note: Building permit has been pulled under 16016-20000-04908	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67059	12041-10000-16466	7333 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	07/17/2012 12:00:00 AM	ADDRESS	33.94247	-118.42449	"New transformers, panels, circuits, and loads to an existing ""Badging Office"" at LAX.  (Per Tim Moore, LAX Inspector, express permit is ok.  Full plan review may be required, subject to field inspection.)  Plan check only for Energy, with Emergency lighting."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67060	14041-10000-00964	380 WORLD WAY Space T62	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	First time tenant for LAX (Tom Bradley), Space T62-R.  Install new panel and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67061	19041-10000-41471	2220 W BEVERLY BLVD	90057	13	136-5A205 314	5154010021	C2-1	Central	Westlake	Westlake North		2085.02	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Info Complete	10/11/2019 12:00:00 AM	ADDRESS	34.06726	-118.27217	T-24 PLAN CHECK FOR A TI FOR CHANGE OF USE FROM OFFICE TO NEW BAR AREA AND RESTROOM IN A THEATRE AND LONGE BUILDING. THE SCOPE OF WORK IS LIMITED TO THE BAR AND THE RESTROOM. SCOPE OF WORK INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 351 SQ.FT B#15016-10002-13498	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67062	17041-20000-23598	7622 N RESEDA BLVD	91335	12	186B125   123	2119001041	[Q]C2-1VL-CDO, [Q]P-1VL-CDO, [Q]R3-1-CDO	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.20917	-118.53586	ti to an existing commercial building, new walls to enclose bathroom.  all lighting and circuits existing to remain.  plan check requested by applicant.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67063	13041-20000-22967	5419 W SUNSET BLVD	90027	13	147A193    65	5544022053	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.09827	-118.30768	NEW FIRE ALARM SYSTEM. 105 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67064	17041-20000-18727	4525 W WILSHIRE BLVD	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	Plan check for energy only. New lighting in subtarranean parking garage, lobby, and restrooms for existing office building. 14,650sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67065	10041-20001-25567	23351 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			PC Approved	06/09/2011 12:00:00 AM	ADDRESS	34.15775	-118.6342	Per Inspector's request, need Title 24 approval.  Plam check is for energy only.<<<<<Add circuits, lights and outlets>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67066	16041-20001-15491	4211 W MONROE ST	90029	13	141B197   162	5539015008	RD1.5-1XL	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM			PC Approved	07/01/2016 12:00:00 AM	ADDRESS	34.08576	-118.28978	Expedite per applicant request(((((Plan check for PV roof mounted system on SFD. System size: 2.5kW with 8 modules and 1 inverter.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67067	16041-10000-40383	2061 N WESTRIDGE ROAD	90049	11	138B133   386	4492011007	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.07302	-118.50112	PV1 roof mounted solar system installation to a single family home. Installing a central inverter rated at 7.6Kw being fed from a total of 35 solar modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67068	16041-20000-38364	19360 W REDBRIDGE LANE	91356	3	159B117    43	2177045007	RA-1	South Valley	Encino - Tarzana	Tarzana	Yes	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.13538	-118.55418	"""$8.64 permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted system. System size is 12.7 kWac and consists of (2) inverters, (45) modules, (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67069	15041-20000-08391	5340 S ALLA ROAD	90066	11	102B157    39	4211008033	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Issued	03/23/2015 12:00:00 AM	ADDRESS	33.9773	-118.42567	Plan check for Title 24 only. Project space an office building. Scope of work is a tenant improvement. Total lighting area = 5,945 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67070	19041-10001-12030	118 S ASTRONAUT ELLISON S ONIZUKA ST	90012	14	130-5A213 136	5161016025	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.05046	-118.24184	Change to approved set by upsizing the fire pump and generator. load calculation being updated. lighting fixture being changed, and T-24 also being updated. All changes under delta-4 only.See comment for detail.(((PC FOR POWER AND ENERGY. NEW 9 STORY 77 UNIT MIXED USE APARTMENT BUILDING OVER 3 LEVEL SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES A NEW 4000A 120/208V 3 PHASE 4 WIRE SERVICE, NEW PANELS, NEW CIRCUITS,  AND NEW LIGHTS. TOTAL AFFECTED AERA IS 125424 SQ. FT. B#15010-10000-02939)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67071	11041-20000-04730	5661 W SANTA MONICA BLVD	90038	13	144B193   679	5536012010	(T)(Q)RAS4-2D	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			03/10/2011 12:00:00 AM			Corrections Issued	04/29/2011 12:00:00 AM	ADDRESS	34.09093	-118.31297	Core and shell for a new bulding with 3 stories and a basement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67072	18041-20000-18250	16841 W OAK VIEW DR	91436	5	168B133   412	2289018018	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM			Reviewed by Supervisor	06/20/2018 12:00:00 AM	PIN	34.15498235	-118.50072065	Plan check for a PV1 ground-mounted PV system. System size is 10 kWac and consists of (1) inverter and (43) modules.Note: Building application has been generated under 18016-20000-15526	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67073	17041-20000-22517	820 S WILTON PL	90005	4	132B189   709	5092026029	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	12/01/2021 12:00:00 AM	ADDRESS	34.0573	-118.3141	Plan check for a fire alarm system for a 18-unit, 4-story apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (92) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67074	15041-20002-42064	4910 N TOPEKA DR	91356	3	168B121   100	2176029031	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2016 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.15907	-118.54644	01/14/2016 Changes to an approved set of plans. Changes have been made to the single line diagram to reflect field installation (MSP is a 400-amp split bus panel). PV system has remained the same.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (44) modules, (44) micro-inverters, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67075	13041-10000-33101	7168 N SALE AVE	91307	12	183B097   884	2024040026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	34.20078	-118.61891	PV1, Install 4 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE3800A-US. (16)modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67076	19041-20000-49789	1015 S GAYLEY AVE Suite 100	90024	5	132B149    55	4363025011	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	03/18/2021 12:00:00 AM		Issued	03/18/2021 12:00:00 AM	ADDRESS	34.06157	-118.44786	TENANT IMPROVEMENT INSTALL (5) NEW PANELS AND EQUIPMENTS ON EXISTING SERVICE. T24 INCLUDED TOTAL SQUARE FOOTAGE = 1260 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67077	13041-10000-35496	222 S FIGUEROA ST OUTDOOR-LIGHTING	90012	14	132A211    53	5151016013	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.01	Electrical	Electrical	Apartment			12/19/2013 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.05621	-118.25318	T24 PART 6 ENERGY OUTDOOR LIGHTING; NEW POLE LIGHTING IN EXTERIOR COURTYARD FOR 71,458 SQ FT AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67078	17041-10004-42332	5971 W VENICE BLVD 2ND & 3RD-FLOORS	90034	10	126B173   912	5066003021	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM			PC Approved	11/27/2018 12:00:00 AM	ADDRESS	34.03865	-118.37272	CHANGES TO APPROVED SET OF PLAN (DELTA 2.5 CHANGES ONLY), CHANGES INCLUDE ADDDING PANEL 3A1 BACK FROM ORIGINAL PROPOSED PLAN.ORIGINAL PERMIT TENANT IMPROVEMENT: INTERIOR REMODEL ; FULL PLAN CHECK ON FLOORS 2 AND 3 OF EXISTING CLINICAL SPACE (MEDICAL OFFICE) NO HOSPITAL.NEW PANELBOARDS AND CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67079	15041-20000-10708	4549 E ZANE ST	90032	14	142-5A231 353	5213028015	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.08271	-118.18514	Plan check for a PV1 roof-mounted PV system. System size is 3.4 kWac and consists of (16) modules and (16) micro-inverters. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67080	13041-20002-26172	7112 N LASAINE AVE	91406	6	183B133   300	2228030025	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.19958	-118.51087	pv1 single family dwelling. total system size 4.2 kw AC using 22 modules. using transofrmerless inverter nonstandard plan. 2 strings.((CHNAGES TO APPROVED SET OF PLANS. CLOUDED DELTA B))$0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67081	14041-10001-07919	16743 W MARQUEZ TER	90272	11	129B121   711	4419014026	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.04746	-118.54603	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 10.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U & SE3800A-US-ZB-U(41) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67082	14041-10000-02688	1534 W 213TH ST	90501	15	051B193   479	7349018010	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Closed	03/31/2016 12:00:00 AM	ADDRESS	33.83536	-118.30507	PV1, Install 4.25 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U.(17) Modules: TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67083	14041-10001-13053	9649 W LAWLEN WAY	90210	5	144B161   412	4355019043	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.09484	-118.41636	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67084	15041-20000-26821	3125 S LA CIENEGA BLVD	90016	10	123B173  1581	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.02985	-118.37256	Title-24 plan check only.  Total area = 7,389 sq. ft.  T.I. to existing commercial office space.  2008 energy code used (building permit #14016-10000-05541).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67085	18041-10000-01267	333 S GRAND AVE 41ST FLR.	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	T-24, PC FOR ENERGY ONLY. INTERIOR REMODEL OF CORRIDOR, ELEVATOR LOBBY AND RESTROOMS ON THE 41ST FLOOR OF  OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2672 SQ. FT. B#17016-10000-38303	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67086	15041-20000-27924	1888 S CENTURY PARK EAST	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.06104	-118.41402	1ST FLOOR LOBBY RENOVATIONS NEW FINISHES, MILLWORK, NEW GLASS GUARDRAILSpc for energy only. new lighting. t24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67087	11041-10000-13895	15233 W VENTURA BLVD 8th & 9th-Floor	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM			PC Approved	07/06/2011 12:00:00 AM	ADDRESS	34.1538	-118.46502	T.I.  Remodel of office spaces on the 8th and 9th floor of the building.  Plan check is for energy and emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67088	15041-10000-19731	380 WORLD WAY LV.3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM			PC Info Complete	06/23/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	TOM BRADLEY INTL. IN-TRANSIT CORRIDOR REMODEL. PC FOR ENERGY ONLY.  thia is a plan check only.  permit is pulled under 15041-10001-19731	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67089	12041-20000-24196	16000 W VENTURA BLVD #550	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/10/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	11/14/2012 12:00:00 AM	ADDRESS	34.15584	-118.48164	CHange to lighting to an existing office space in a high rise building on the 5th floor.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67090	17041-10000-39445	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	12/18/2017 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	TI TO EXISTING 4-STORY OFFICE/DATA CENTER AND (N) ROOFTOP PLATFORM FOR MECHANICAL EQUIPMENT : NEW 20000SF DATA CENTER; 2EA  2000 KW/12.47KV GENSETS; 2 EA  3X750 KVA 480V UPS MODULES; 2 EA  5000KVA/12.47KV XFMRS; AND ASSOCIATED SWGRS AND DISTRIBUTION BOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67091	18041-30000-20215	12020 W CHANDLER BLVD SUITE #100	91607	2	171B165   117	2348016099	C2-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Issued	06/22/2018 12:00:00 AM	ADDRESS	34.16825	-118.39512	Energy plan check for the 1st floor of an office T.I located in a commercial building. Scope includes new lighting and equipment; total area for T24 is 5695-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67092	17041-20001-37564	407 E 120TH ST	90061	15	084B205  1139	6083029027	R3-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			10/18/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	33.92385	-118.26736	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system mounted on carport in apartment complex. System is serving apartment building 1. Total system size: 22.8kW ungrounded.(3) SolarEdge 7.6kW inverters. (108) 280W pv modules.Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67093	11041-10000-20672	1402-1406 S ELKGROVE CIR BLDG 16	90291	11	111B145   518	4243001035	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.00133	-118.4587	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67094	19041-30000-34247	5900 W WILSHIRE BLVD # 2375	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.06237	-118.35809	ENERGY PC ONLY FOR PROPOSED ALTERATION TO OFFICE BUILDING (APPROX. 2,766SQFT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67095	09041-10001-05825	424 N LAKE ST	90026	13	138A205   242	5157016023	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			02/26/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.07133	-118.26879	This permit is for building B , Original application # 07041-10000-26288 was withdrawn and closed. Permit # 09041-10000-05817 is for building A.((((2-26-10 -- application #07041-10000-26288 was withdrawn by mistake by applicant and permit was issued on 12/31/09 without planc heck therefore this supplemental plan is to verify the plans with original plans and additional panel/ckts added.  Permit number remains as X09LA04881.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67096	19041-20001-10637	3410 S GRANVILLE AVE	90066	11	117B153   825	4249010003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM			PC Approved	06/04/2019 12:00:00 AM	ADDRESS	34.01529	-118.43383	06-04-2019 Changes to an approved set of plan, changes include removed electrical meter (PV System size: 9.18KW AC) Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67097	14041-20000-29806	430 W 6TH ST	90731	15	015B201    89	7455004005	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM			PC Info Complete	10/28/2014 12:00:00 AM	ADDRESS	33.73887	-118.28643	Plan check for energy only. TI to an existing school building. New lighting (incl. emergency) and receptacles. 4,951sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67098	16041-10000-11970	9152 W JANICE PL	90210	4	153B165   368	4388018022	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.11352	-118.39572	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1, rooftop solar installation on SFD, 20 kW AC.   (74) SUNPOWER X21-345       (2) SE10000A-US     SEP400 is being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67099	17041-10000-37202	10250 W SANTA MONICA BLVD # 2380	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Issued	01/08/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant space ""HONEYMEE""  suite 2380"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67100	14041-20000-10828	10921 W ART ST	91040	7	201B173   206	2542011008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.24865	-118.36837	pv1 single family dwelling. total system size 10kw ac using central transformerless inverter. using standard plan. 40 modules. negatively grounded	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67101	13041-10000-16354	9604 N CREBS AVE	91324	12	201B121   655	2763024010	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	07/09/2013 12:00:00 AM		Permit Finaled	08/02/2013 12:00:00 AM	ADDRESS	34.24483	-118.54435	PV1.  Install roof-mounted 10.05 kW DC solar array, interconnect with main service panel.  {41 modules: TSM-245PC05/PA05.18} {2 inverters: Power-One Aurora PVI-3.6-OUTD-S-US-Z}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67102	16041-20001-07706	17985 W PACIFIC COAST HWY	90272	11	126B113     6	4416005012	A1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	34.04184	-118.56677	Plan check oonly for installation of 500 A automatic transfer switch for a redundant chiller (Kirk Key interlock) on optional standby power, per inspector request.  Design build plan set.  [[ Variance has been submitted for approval of  Tapped MSB Prior to Recert by UL ]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67103	17041-10001-28918	9950 N BALBOA BLVD	91325	12	204B133   695	2685007015	A2-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.25194	-118.50219	PC FOR CHANGES TO APPROVED  UNDER DELTA 3 SET FOR PV SYSTEM ROOF MOUNTED SYSTEM. SCOPE INCLUDES REVISIONS TO SINGAL LINE TO ADDRESS INSPECTION AND FIELD CHANGES.THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67104	16041-10001-41235	5300 S MCCONNELL AVE	90066	11	105B157   681	4211006018	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM			PC Approved	03/13/2017 12:00:00 AM	ADDRESS	33.97954	-118.42015	RECHECKING FOR LOST SET OF PLANS. PC AND RESTAMP AS RTI SET. PERMIT TO STILL BE ISSUED UNDER MASTER APP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67105	19041-10000-34455	608 S HILL ST	90014	14	129A211   151	5144003015	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Issued	10/01/2019 12:00:00 AM	ADDRESS	34.04696	-118.25321	NEW FIRE ALARM INSTALLATION IN A HIGH RISE OFFICE BUILDING. TOTAL OF 265 FA DEVICES AND 1 FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67106	14041-20000-03442	17124 W LORILLARD ST	91344	12	213B133    65	2607003025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.28411	-118.50546	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTNADARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67107	15041-20000-42587	17278 W SUNDERLAND DR	91344	12	216B133   153	2606009023	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.29074	-118.51021	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.95KWdc/6.0KWac.(30)MODULES-KYOCERA #KU2656ZPA(1)INVERTER- ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67108	15041-20000-26465	9180 N SAN FERNANDO ROAD	91352	6	198B169   147	2538008022	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.2363	-118.38969	Plan check for Title 24 only for office and wearhouse T.I. for Stover Seed Company. Total area: 632 sqft. Newly connected load is less than 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67109	19041-10000-38874	5500 W 98TH ST RRIS	90045	11	093B173   581	4128022906	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	07/23/2020 12:00:00 AM		Permit Finaled	03/20/2024 12:00:00 AM	ADDRESS	33.94764	-118.37749	LAX LAMP CONRAC CSB/RR/IS 5 STORY RENTAL CAR BUILDING. MED VOLTAGE. TOTAL AREA: 5,732,986 SQR FTBUILDING PERMIT: 19010-10000-01608	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67110	13041-20000-17274	17643 W ROMAR ST	91325	12	204B129   567	2734012057	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.25503	-118.5193	New PV rooftop system using Microinverters.  sfd	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67111	18041-10000-21985	2029 S CENTURY PARK EAST 7th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN EXISTING RESTROOMS ON THE 7TH FLOOR. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67112	14041-10003-05603	5311 S CRENSHAW BLVD #A-#B	90043	8	108B185   116	5013018006	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	33.99449	-118.33114	05/10/16 Change to approved set by modifying the plan with delta-13 and 14. Main scope includes (2) new UPS, (3) panels and (27) circuits.Revisions to approved set.  Delta revisions 3, 6, and 9.  Change of feeders from copper to aluminum for value engineering, extra classroom (architectural revisions), lighting control changes throughout, and updates to elevator motor specifications.  (((PLAN CHECK FOR POWER AND ENERGY FOR A NEW 3 STORY CHARTERED SCHOOL. 2 SERVICES.FIRE ALARM PLANS TO BE SUBMITTED SEPERATELY. (variance was filed)BUILDING P# 14010-10000-00540 : NEW 3 STORY SCHOOL (74' WIDE X 340' LONG) CONSTRUCTION TYPE II-B  FULLY SPRINKLERED, TOTAL SQUARE FOOTAGE 54,567 SF)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67113	15041-10000-31140	2029 S CENTURY PARK EAST #2570N	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	T-24. PC FOR ENERGY ONLY. TI ON EXISTING HIGH RISE COMMERCIAL BUILDING(OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING. TOTAL AREA 1315 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67114	14041-10000-14392	11800 N FOOTHILL BLVD	91040	7	210B165   540	2528002901	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District, Pacoima	YES	9800.21	Electrical	Electrical	Public Safety Only			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.273	-118.39313	NEW FIRE WARNING SYSTEM FOR A 2-STORIES COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67115	14041-10000-34937	8921 N QUARTZ AVE	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.23274	-118.56488	Title 24 plan check only.  Total area = 7480 sq. ft.Remove HID lighting and replace with LEDs	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67116	18041-10000-14620	1211 S MEYLER ST	90731	15	015B197  1468	7458018027	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM			PC Info Complete	04/20/2018 12:00:00 AM	ADDRESS	33.73307	-118.29701	PC FOR OFFICE TI ,Change of use from bakery to office and studio unit at ground level of existing 2-story mixed use building FOR TITLE 24 ENRGY ONLY. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA  1008 SQ.FT (INDOOR AND OUTDOOR).Permit fees paid under 19041-40000-25975. B#18016-40000-10415	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67117	16041-10001-21889	7954 N MCLAREN AVE	91304	12	189B097   442	2014012020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Expired	08/01/2018 12:00:00 AM	ADDRESS	34.2153	-118.62433	PC AND PERMIT FOR CHANGE IN MODULES TYPES AND SIZES. NOW USING 275W DC MODULES AND ENPHASE M250 MICROINVERTER. NONSTANDARD PLAN. TOTAL KW OUTPUT = 52.28KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67118	17041-20003-06492	1540 W FRANCISCO ST	90501	15	057B193    29	7351021033	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			PC Approved	10/29/2018 12:00:00 AM	ADDRESS	33.84927	-118.30492	09/28/2018 Changes to an approved set of plans. All changes have been clouded. Changes throughout. Module count has remained the same. Inverter model has changed; power output rating has been lowered. Inverter count has increased by (4) for a total of (16) inverters. Routing details modified - cable tray used. *****Previous Work Description*****Revisions to approved set of plans.  Change of module manufacturer/part no., total number of modules (reduced from 4,104 to 3,456), and equipment layout on roof.   No changes made to AC side of system.  Approval for clouded portions only.  (((Plan check for installation of solar PV system, roof-mounted on commercial building.LADWP Feed-in-Tariff project ~ new 1600A switchboard.960 kW ungrounded system [12 - 80kW inverters]. (4104) 340W PV modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67119	18041-20000-12053	8700 W CHALMERS DR	90035	5	132B169   109	4333012025	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			04/03/2018 12:00:00 AM	10/05/2018 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	34.06082	-118.38155	Plan check power and energy for 4 story 8 units multi family dwelling Total area: 7929 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67120	17041-20000-43356	4904 S SAN PEDRO ST	90011	9	111A205   227	5109022900	OS-1XL	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/01/2017 12:00:00 AM	PIN	33.99751407	-118.26742354	Plan check for t24 energy only. New single story office/storage maintenance building. New lighting (incl. emergency) and receptacles. T24: indoor - 2760sqft; outdoor - 16580sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67121	14041-10001-07942	9270 N NAGLE AVE	91331	6	198B153   664	2642023020	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.23876	-118.43569	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1,INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(13) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67122	15041-20001-28725	4334 N MATILIJA AVE 1-27	91423	4	165B153   431	2271017029	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			09/01/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	ADDRESS	34.14952	-118.43388	EXPEDITE FEESPV2 COMMERCIAL ROOFTOP. TOTAL SYSTEM SIZE 15.4KW AC USING 2 CENTRAL INVERTERS AND 66 MODULES IN TOTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67123	17041-10000-02318	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.13829	-118.34154	FULL PLAN CHECK FOR REMODEL DOG WASH. 3 OF 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67124	16041-20001-41176	10705 N TURNBOW DR	91040	7	207B189   698	2547009002	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.26337	-118.32433	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP. Derating main breaker to 175A. 3.8kW ungrounded system. (13) 260W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67125	10041-10000-23158	2500 S NAVY WAY PIER 400	90731	15	021B209   245	7440022909	M3	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	02/16/2011 12:00:00 AM	ADDRESS	33.73363	-118.2408	"INSTALL A NEW FIRE ALARM SYSTEM IN THE ""MARINE OPERATION"" BUILDING. (PIER #400)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67126	10041-20000-02091	10960 W WILSHIRE BLVD 21st fl.	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			02/05/2010 12:00:00 AM	03/24/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.058	-118.44597	21st floor office t.i.Energy, emergencyRequest for Modification to separate Fire Alarm  systen filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67127	13041-10000-33030	3061 N BROOKDALE ROAD	91604	2	156B169   169	2382006001	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.12645	-118.39199	PV1. ROOFMOUNTED SOLAR SYSTEM, INTERCONNECT WIT MAIN PANEL. SYSTEM SIZE: 9 KW. STANDARD PLAN(36) TRINA SOLAR # TSM-250(1) FRONIUS IG PLUS 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67128	15041-10001-33887	900 N CAHUENGA BLVD Suite B	90038	13	144B185  1190	5533019012	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM			PC Approved	11/04/2016 12:00:00 AM	ADDRESS	34.0873	-118.32862	11/04/16Changes to an approved set of plans. All changes are made under delta 7. Changes to reflect what is on the field per inspector's request.Note: Permit is pulled under PCIS#15041-10000-33887(((((Title 24 plan check only.  Total area = 6,524 sq. ft.    T.I. to office space including new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67129	16041-30000-32495	4201 W WILSHIRE BLVD 1st RR	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.06189	-118.31911	Plan check for Title 24 only in extisting space 1st floor 2 rest rooms in high-rise building. Total area: 1,015 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67130	10041-10000-05507	701 N STONE CANYON ROAD	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	REMODELING OF THE FOOD AND BEVERAGE  AREAS  IN THE MAIN HOUSE AT THE BEL AIR HOTEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67131	11041-10000-20615	972-980 E ELKLAND PL Bldg 2	90291	11	111B145   913	4243002066	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99903	-118.45916	REPAIRS & HISTORICAL REHABILITATION  / TI OF 17 UNITS APARTMENT BUILDING.  (PER LL) VARIANCE IS SUBMITTED TO SEPARATE THE FA PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67132	16041-20000-43694	6200 N VARIEL AVE	91367	3	177B105   132	2149004024	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Info Complete	12/13/2016 12:00:00 AM	ADDRESS	34.18341	-118.59258	PLANCHECK FOR TEMPORARY SERVICE AND MAIN DISTRIBUTION ONLY. 277/480 SERVICE AND 600 AMP DISTRIBUTION BOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67133	16041-10000-19277	777 S FIGUEROA ST STE 1550	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.04828	-118.26116	PC FOR T24 ENERGY ONLY. NEW LIGHITNG IN OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67134	17041-10001-18217	16925 W DORMIE PL	91436	5	168B133   451	2289016039	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM			PC Approved	07/10/2017 12:00:00 AM	ADDRESS	34.15405	-118.50213	Expedite fees only.       Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system.  Total system size = 16.2 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67135	18041-20001-15772	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM			PC Approved	10/17/2018 12:00:00 AM	ADDRESS	34.04403	-118.2199	Revisions to approved set of plans.  Changes to lighting system. (((Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 4,435 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67136	15041-20000-08045	10250 W CONSTELLATION BLVD 2nd Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title-24 (energy) only.  Total area = 3,200 sq. ft.T.I. to existing commercial highrise space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67137	16041-10000-09139	11111 W SANTA MONICA BLVD #1650	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.04771	-118.44481	T-24, TI IN AN OFFICE SPACE IN SUITE 1650. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN OFFICES AND NEW RECEPTACLES IN THE RECEPTION AREA. TOTAL SQ. FT. 381.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67138	16041-30001-35005	5757 W CENTURY BLVD # 808-# 820	90045	11	090B169    24	4125025036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	33.9457	-118.38274	02/09/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1 and Delta 2. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance forms.*****Previous Work Description*****Title 24 plan check.  T.I. to existing commecial office highrise building.  New lighting, receptacles, and one new subpanel.  Total area = 7,980 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67139	18041-10001-01065	1256 W 185TH ST	90248	15	060B197   189	6109008014	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	33.86262	-118.29629	Supplemental permit for 200A subpanel and plan check for rooftop solar for 3.91kW(AC) system. Installing 17 new modules with microinverters, new panel connected to line side of main panel breaker. PV System Permit fee is covered under 18041-90000-01065	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67140	14041-20001-07223	11915 N LAUGHTON WAY	91326	12	216B125    96	2870023006	RE15-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.29002	-118.53501	(((Expedite fees)))PV1 MICROINVERTER NONSTANDARD PLAN. TOTAL SYSTEM SIZE 6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67141	16041-20000-44595	21315 W LOPEZ ST	91364	3	171B105   946	2167006017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.16233	-118.59531	Plan check for PV roof mounted system. System size: 11.0kW with 2 inverters(6.0kW and 5.0kW) SMA SB6000TL and SMA SB6000TL and 35 modules SunPower SPR32NE-WHT-D	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67142	16041-20000-19810	540 S CATALINA ST	90020	10	135B197   936	5502022019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.06411	-118.29524	$0 permit fee is due to State Senate Bill SB 1222PV2.  Install 58.48 kW roof mounted PV system.  (2) separate PV systems on building occupying same rooftop.  System 2 of 2.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67143	13041-20000-09373	23361 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.15827	-118.63423	Remodel with change of use to beauty saloon.  Plan check for electrical, T24 and emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67144	16041-20001-34801	9310 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.23949	-118.53589	changes to an approved set of plans. changes noted delta 1.  changes include different light fixtures and energy calculations.  this is plan check only.PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR RESTAURANT. 2584 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67145	16041-20000-07794	5100 W WILSHIRE BLVD	90036	4	132B181    39	5507026001	(T)(Q)RAS4-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			03/04/2016 12:00:00 AM	04/13/2016 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.06187	-118.34094	New fire alarm system with central station monitoring for 6-story mixed-use building with 2 stories subterranean parking.  New FACP with (428) notification and initiating devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67146	19041-20000-30945	2727 S CLUB DR	90064	5	126B161    85	4308003006	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.04209	-118.40577	Installation of 40.5 kWh energy storage system and associated distribution/relocation of loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67147	12041-10000-00681	17738 W HORACE ST	91344	12	210B129   655	2712012002	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2012 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.2696	-118.52115	New 7KW rooftop mounted photovoltaic system, with 36 modules, for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67148	19041-10000-41121	11766 W WILSHIRE BLVD SUITE-1701	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.04	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Info Complete	10/10/2019 12:00:00 AM	ADDRESS	34.04804	-118.46227	Energy plan check for an office T.I located on the 17th floor of a high rise building. Scope includes new lighting and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67149	18041-20000-15027	20212 W ARCHWOOD ST	91306	3	180B113   164	2134016008	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2018 12:00:00 AM	04/24/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.19245	-118.57396	PV1.  Install 4.95 kW DC roof mounted grid tied PV system.  (15) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67150	14041-20000-12630	6501 N TOPANGA CANYON BLVD	91303	3	180B101   634	2139002029	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.1883	-118.60612	TI of (E) single-story commercial restaurant building.  New downlights over counterspace and replacement of exterior lights.  Plan check for Title 24 for changes to interior and exterior lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67151	15041-10001-23464	11985 W BLUFF CREEK DR WORKSPCE	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			Re-Activate Application	11/03/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	(11/2/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE REVISIONS TO THE LIGHTING AND ENERGY CALS.  FULL PC, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER IN THE WORKSPACE. LOADS FOR THE CAFETERIA IS NOT PART OF THIS SUBMITTAL AND IS COVERED UNDER APP#: 15041-10000-23464   TOTAL SQ. FT. 25417. PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67152	11041-20001-11900	1801 W OLYMPIC BLVD UPS	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake			2095.20	Electrical	Electrical	Commercial			12/07/2011 12:00:00 AM	01/12/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.05046	-118.27663	Revision to previously approved plans.  No change in lighting.  No loads added to system, just relocated to different distribution boards.  Electrical systems only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67153	13041-10001-28795	642 W ETTA ST	90065	1	145-5A221  53	5452004043	RE20-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	01/16/2014 12:00:00 AM	ADDRESS	34.09439	-118.21753	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. TRANSFORMERLESS UNGROUNDED. SYSTEM SIZE: 4.25 kW.(17) TRINA SOLAR # TSM-250(1) POWER ONE # AURORA PV1 3.6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67154	15041-10000-22338	9647 N PINE ORCHARD ST	91331	7	201B161   969	2624013***	(T)(Q)RD5-1, RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.24504	-118.40958	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67155	14041-20001-35207	707 W WILSHIRE BLVD 46TH FLOOR	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	Changes to approved set.  New fixtures being used.  Updated photometrics and Title-24.       *********       PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. NO CHANGE IN OCCUPANCY.  NEWLY CONNECTED LOAD < 400 AMPS. 16600 SQFT. 46TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67156	19041-10000-44042	9911 W PICO BLVD	90035	5	132A165   355	4330005043	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM			PC Info Complete	05/15/2020 12:00:00 AM	ADDRESS	34.05339	-118.40441	Core and shell plan check for a high rise, service size 5000A, 480/277V, 3Ph, 4wire.  Area of scope 178,641SF.PER BUILDING PERMIT #19016-10000-22714CONVERT ROOFTOP PARKING TO AMENITY  LEVEL, REMODEL. NEW RAMP AT GARAGE, CONVERT PORTIONS OF TENANT AREAS TO PARKING , CONVERT SOME PARKING TO TENANT AREAS,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67157	19041-20000-06756	10933 N CARTWRIGHT DR	91311	12	210B113   249	2708029008	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2019 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.26957	-118.56658	PV1.  Install 6.03 kW roof mounted grid tied PV system.  (18) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67158	13041-20000-10819	3041 W 7TH ST	90005	10	132B197   169	5077011018	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Apartment			04/26/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	07/19/2013 12:00:00 AM	ADDRESS	34.05992	-118.29006	CHANGE DRYER FROM 120VOLT TO 208 AND REDUCE LOAD ON OVEN TO 5KW. Plan check for DELTA G ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67159	11041-20000-16205	1200 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/08/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29179	"New 3.23 Kw Pv solar equipment ( max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) system for an apartment Bldg"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67160	17041-10000-32565	17531 W RINALDI ST	91344	12	213B129   170	2607011031	A1-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.27955	-118.51566	REPLACE  EXISTING FIXTURES WITH LED  FIXTURES TITLE 24 ONLY.TOTAL AFFECTED AREA 66650 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67161	18041-10000-22450	3500 W WILSHIRE BLVD #204	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2123.04	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.06157	-118.30077	TI to an existing space, no change of use, Scope of work includes new lighting in parameter area and receptacles only. Total Sq. Ft. 80.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67162	14041-10000-33659	17732 W MELVIN LANE	91325	12	195B129   337	2768012038	RA-1	North Valley	Northridge	Northridge South		1151.04	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.23045	-118.52155	Installation of roof mounted solar PV array in addition to existing system.  1 new load center, 3 new inverters, and 69 new modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67163	10041-10000-06831	668 S SYCAMORE AVE	90036	4	135B181   878	5507022031	[Q]C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/14/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	08/24/2011 12:00:00 AM	ADDRESS	34.063	-118.34279	title 24 for outdoor parking. pole lights	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67164	17041-10000-30886	10250 W SANTA MONICA BLVD # 1605	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			Verifications in Progress	11/02/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full Plan check for first time tenant ""The Kafe"" on Westfield Century City Ste.#1605"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67165	19041-20000-41794	10810 W RENNES ST MS4	91602	2	168B177   842	2421030001	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	06/08/2020 12:00:00 AM	ADDRESS	34.15442	-118.36623	New 600A 240/120V 1ph-3w service supplying (5) SFDs and house panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67166	15041-20001-43189	20720 W VENTURA BLVD 3RD FLR	91364	3	171B109    80	2166014013	(Q)CR-1VLD, (Q)P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.16654	-118.5845	02-11-2016 Change to approved set of plans. Changes include addition of lighting fixtures and type of the fixture in corridor. {{{{{{{{{T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING 3-STORY COMMERCIAL BUILDING ON THE 3RD FLOOR (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 7267 SQ. FT.}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67167	18041-20000-33877	6111 N MONTEREY ROAD	90042	14	150A231    37	5312004009	RD1.5-1	East Los Angeles	Northeast Los Angeles	Hermon	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	02/01/2020 12:00:00 AM	ADDRESS	34.10692	-118.18358	new 800 amp service to feed (8) individual SFD.  plan check for power only.building application number 16010-10000-06323	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67168	19041-20000-15604	2933 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.10439	-118.24372	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67169	12041-10000-31242	3756 W AVENUE 40 unit H	90065	14	154-5A217  22	5472001070	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.00	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.1195	-118.22799	PLAN CHECK FOR TITLE 24. EXISTING RESTAURANT TO NEW RESTAURANT. LOAD <400 A.occupant load <16	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67170	11041-20000-01325	5525 N KLUMP AVE	91601	4	174B173  1181	2350006026	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			01/21/2011 12:00:00 AM	06/27/2011 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.17064	-118.37542	New 5-story apartment building.  2000A electrical service.  Plan check for power and energy. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67171	19041-20000-31166	5550 N EL CANON AVE	91367	3	174B089   536	2046017001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.17078	-118.64807	PV1. INSTALL (37) ROOFMOUNTED AC MODULES ON NEW SERVICE. SYSTEM SIZE IS 14.80 KWDC AND 13.46 KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67172	13041-10000-05135	6374 W SUNSET BLVD # D	90028	13	147A187   590	5546015043	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			02/27/2013 12:00:00 AM			PC Approved	02/27/2013 12:00:00 AM	ADDRESS	34.09768	-118.32839	REMODELING OF THE ROADSIDE-CAFEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67173	17041-20000-19596	7947 N ETHEL AVE	91605	2	189B161   445	2303026015	RA-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.21538	-118.41631	Plan check for solar pv system, roof-mounted on SFD.10kW ungrounded system.(25) 350W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67174	16041-10002-20314	19600 W PLUMMER ST	91324	12	198B117    69	2761036148	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Closed	03/08/2017 12:00:00 AM	ADDRESS	34.2426	-118.5602	Changes to approved set of plans Optometrics office. Change in lighting configuration and light fixtures. Uptdaded Title 24. Total area: 1,821.Note changes under delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67175	17041-10000-43703	10460 N MT GLEASON AVE	91042	7	204B193   160	2558001029	(Q)C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Issued	12/05/2017 12:00:00 AM	ADDRESS	34.2594	-118.30249	"PC for new outdoor sign lighting. Installing new 9'5""X 24"" CitiBank LED fixture."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67176	18041-20000-43747	20830 W SPRUCE CIR 30	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.29535	-118.58866	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67177	18041-10000-42370	10100 N MELVIN AVE	91324	12	204B117   443	2726010007	RE11-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	34.25391	-118.5603	Permit Fee: $2 Due to AB1414Plan check for a PV1 11.4kw AC /13.42 DC roof mounted system with (1) 11.4KW inverter, (44) modules and optimizer inter connecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67178	17041-10000-41091	420 N SOTO ST	90033	14	129A225   159	5177028012	C1-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.04817	-118.20672	REPLACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67179	16041-10000-43081	2738 N HYPERION AVE	90027	4	151-5A205 230	5434036029	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	Yes	1951.00	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	01/25/2017 12:00:00 AM		Issued	01/25/2017 12:00:00 AM	ADDRESS	34.10767	-118.27179	T-24, PC FOR ENEGY ONLY. SCOPE INCLUDES ADDING EXTERIOR LIGHTS FOR A PARKING LOT. TOTAL AFFECTED ARE IS 5893 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67180	11041-20000-11892	5400 W HOLLYWOOD BLVD	90027	13	148-5A193 139	5544021029	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			07/27/2011 12:00:00 AM			Corrections Issued	09/22/2011 12:00:00 AM	ADDRESS	34.10152	-118.3074	PLAN CHECK POWER AND ENERGY FOR NEW MIXED USE BLDG RETAIL AND 40 UNITS APARTMENT WITH SUBTERRANEAN PARKING GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67181	17041-20000-33633	515 S FIGUEROA ST 9TH FLR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for energy only. TI to restrooms on 9th floor of high rise building. New lighting (incl. emergency) - 718sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67182	19041-10000-44144	9150 S LOYOLA BLVD APF	90045	11	093B161     3	4119006913	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	11/04/2021 12:00:00 AM	ADDRESS	33.95408	-118.41705	Full PC for power and energy.  Scope includes a new 5000A 480/277V 3 Phase 4 Wire service, new distribution board, new transformers, new panels, new circuits, and new lighting. Total affected area is 630,069 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67183	13041-10000-13314	1200 S CLUB VIEW DR 11th floor	90024	5	135B157   112	4327024019	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			05/22/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	34.06748	-118.42481	Alteration to 11th story unit #1101 and adjacent common area in existing highrise condominium building.  Buildout electrical systems to tenant space for new luxury residence.  Emergency lighting and convenience receptacles to be provided in common area.  Title 24 plan check only for corridor lighting.  Permit to be issued at electrical plan check counter.  Newly connected demand load to be 126A.  This project is one of ten tentative such alterations to various luxury apartments in this highrise apt bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67184	14041-10000-03659	833 E 3RD ST	90012	14	129A215   259	5163007010	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	PIN	34.04615917	-118.23530019	Plan check for power and energy. core and shell  improvement for a commercial. Existing building. New service with 1600A, 227/480V, 3PH, 4WIRE undergrounded . Projected area in lighting work is approx. 5804 SQ FT ( 2204 indoor, 3600 outdoor) . 6 section with bus rating 1600 A.sERVICE LOAD SHOWS THE HOUSE METER AND THE REST IS FUTURE. fUTURE TENANATS NEED SEPERARTE PLAN CHECK APPROVAL.  THIS PLAN CHECK IS FOR CORE AND SHELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67185	16041-10001-30601	1149 S LOS ANGELES ST	90015	14	126A209   302	5139016018	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM			PC Approved	11/28/2016 12:00:00 AM	ADDRESS	34.03729	-118.25832	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. CHANGES TO SERVICE ENTRY. USING UNDERGROUND PULL SECTION WITH METHANE MITIGATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67186	14041-10001-29867	722-736 E WASHINGTON BLVD	90011	9	121-5A209 156	5131006005	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Apartment			06/24/2016 12:00:00 AM			PC Approved	06/24/2016 12:00:00 AM	ADDRESS	34.02718	-118.2568	6/24/16: Changes to apporoved set noted under Delta-1: removed Lower Level Exit sign on 2nd, 3rd, and 4th floor.<<FULL PLAN CHECK FOR NEW 4 STORY MULTI-FAMILY BUILDING WITH  55 APARTMENT UNITS.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67187	15041-10000-02906	15300 W VENTURA BLVD	91403	4	168B145   952	2276039007	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.15368	-118.4665	Plan check over the counter. Fire Alarm plan check. NOT a public school. Restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67188	12041-10000-27624	3620 S MCCLINTOCK AVE 7th fl	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.0213	-118.28935	remodel offices, corridors in office spaceplan chk is for title 24 and  1 ea emergecy ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67189	19041-10000-37548	218 N ALVARADO ST	90026	13	136-5A205 224	5157021028	R4-1	Central	Westlake	Echo Park		2084.02	Electrical	Electrical	Apartment			09/19/2019 12:00:00 AM	06/13/2022 12:00:00 AM		Issued	06/13/2022 12:00:00 AM	ADDRESS	34.0682	-118.26914	FULL PLAN CHECK FOR A NEW 60 UNITS, 5 STORIES RESIDENTIAL APARTMENT BUILDING OVER 2 LEVELS OF SUBTERRANEAN PARKING. SCOPE INCLUDES NEW 1600A SERVICE WITH IMERGENCY INVERTER. TOTAL AFFECTED AREA IS ????? (MISSING T-24, customer to provide T-24 by 9/23/2019 )HAZARDOUS LOCATIONFUTURE PROJECT ADDRESS IS PRINTED ON THE PLANS (222  N. ALVARADO ST)B#19010-10001-02379MODIFICATION FOR FA SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67190	13041-20000-20345	1625 N BRUCE CT	90026	13	141A211   114	5419012018	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Expired	08/26/2015 12:00:00 AM	ADDRESS	34.08033	-118.25312	PV1 TRANSFORMERLESS. 5.39 KW SYSTEM. 22 MODULES AND 1 INVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67191	14041-20000-07064	10155 N JANETTA WAY	91040	7	204B173   162	2542031025	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.25537	-118.3662	PV1 TRANSFORMERLESS SYSTEM WITH OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67192	19041-10000-39727	1825 N DOHENY DR	90069	4	150B169  1216	5561008025	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Expired	11/08/2023 12:00:00 AM	ADDRESS	34.10528	-118.38823	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIVIA 7.6 NA G4) USING RAPID SHUTDOWN DEVICES WITH ESS(TESLAPOWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67193	18041-10000-30431	3303 N BROADWAY	90031	9	138A225    15	5208012021	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	04/05/2019 12:00:00 AM		Refund in Progress	12/21/2020 12:00:00 AM	PIN	34.07411316	-118.20631504	PC FOR FIRST TIME TENANT FOR RESTAURANT. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 2011 SQ.FTB#  CORE AND SHEEL     15010-20000-01146         TENANT                              18016-10000-25652	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67194	19041-10000-41482	1818 S MANHATTAN PL	90019	10	126B193   693	5073013901	C2-2D-CPIO	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			Reviewed by Supervisor	10/23/2019 12:00:00 AM	ADDRESS	34.04123	-118.30996	POWER PLAN CHECK FOR 400A SERVICE 120/208 3PH 4W. T-24 EXEMPT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67195	12041-20000-01016	9223 N OWENSMOUTH AVE	91311	12	198B105   134	2746012039	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	01/17/2012 12:00:00 AM		Permit Expired	02/10/2014 12:00:00 AM	ADDRESS	34.238	-118.60204	T.I. to existing building in packaging area.  Install general/emergency light.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67196	13041-10000-22569	7600 N GRAYSTONE DR	91304	12	186B089    63	2027026042	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	12/03/2013 12:00:00 AM	ADDRESS	34.20976	-118.65447	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN (GROUNDED). SYSTEM SIZE IS 9.555 KW DC AND 7.5 KW AC. [MODULES: TRINA SOLAR # TSM245PC/PA05 |||| INVERTER: FRONIUS # IG PLUS V 7.5]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67197	13041-20000-31367	10700 W SANTA MONICA BLVD SUITE 205	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	11/08/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.05167	-118.432	PC FOR T24 ENERGY ONLY. OFFICES. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67198	19041-10000-08228	21816 W LANARK ST	91304	3	189B105    74	2110002900	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.05	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.21744	-118.60384	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67199	11041-20000-05078	11934 W SAN VICENTE BLVD	90049	11	129B145   177	4265007037	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			03/15/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	04/13/2011 12:00:00 AM	ADDRESS	34.05225	-118.47136	T.I. to existing space.  Install/relocate general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67200	18041-10000-42836	13151 W SHERMAN WAY	91605	2	183B157    35	2327003041	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Issued	11/08/2018 12:00:00 AM	ADDRESS	34.20137	-118.41987	REMOVE OUTDOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67201	19041-20000-36708	4818 N SEPULVEDA BLVD	91403	4	168B145   366	2264003013	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	04/14/2022 12:00:00 AM		Permit Finaled	03/11/2024 12:00:00 AM	ADDRESS	34.15823	-118.46591	Plan check for power and energy Service size: 1200A 208/120 Volts. Total area: 21,088 sq ft.B#19010-20000-00795	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67202	13041-10000-23913	12468 N LONGACRE AVE	91344	12	219B125   123	2601075059	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM			Reviewed by Supervisor	10/08/2013 12:00:00 AM	ADDRESS	34.29631	-118.53624	PV1. PLAN CHECK FOR ROOF MOUNTED SOLAR ARRAY. POSITIVELY GROUNDED.  SYSTEM SIZE 13.8 KW.  40 MODULES.NOTE: APPLICATION NO LONGER VALID DUE TO NEW ENGINEER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67203	14041-20000-27625	739 S GARLAND AVE	90017	1	130-5A207 229	5143009015	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			10/06/2014 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.0508	-118.26704	Plan check for power and energy. TI to 2nd and 3rd floors of existing 3-story apartment building. TI of first floor and service upgrade/equipment approved under plan check #14041-20000-08907, approved plans included with submittal. Fees estimated, verify at later date.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67204	16041-10000-12035	15463 W LONGBOW DR	91403	4	159B145   509	2279029008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.1312	-118.4698	PV1, rooftop solar installation on SFD, 5kW AC.   (19) CS6P-260P-SD      (1) SE5000A-US    SE-P300 is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67205	19041-10000-50282	633 W 121ST ST	90044	15	084B201  1256	6117002019	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	33.92288	-118.28591	NEW PV ROOF MOUTED INSTALLATION WITH A SYSTEM SIZE OF 8.06KW DC/ 7.6KW AC, WITH 26 MODULES (CS6K-310MS), 26 POWER OPTIMIZERS (P320),  ONE CENTRAL INVERTER (SE7600-US), AND A MAIN SERVICE PANEL RATED AT 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67206	15041-20000-14497	12751 W MILLENNIUM Bldg A-Ste 4135	90094	11	102B161  1175	4211033020		West Los Angeles				2756.02	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Plan check for power and energy. Project scope is a first time tenant. Work includes the installation of (1) 250-amp panel, (1) 125-amp panel, and associated loads. Total lighting area = 1,491 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67207	15041-20000-11740	6600 N TOPANGA CANYON BLVD 1058-D	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/20/2015 12:00:00 AM			PC Approved	04/20/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for a Title 24 only. Project scope is a tenant improvement to an existing commercial space. Total lighting area = 1,374 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67208	10041-10000-15149	2500 S NAVY WAY PIER 400	90731	15	021B209   245	7440022909	M3	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Closed	11/05/2012 12:00:00 AM	ADDRESS	33.73363	-118.2408	Install new crane #1 for port of L.A., APM Terminals.  Plan check for power only.NOTE: refer to 10041-10K-15147 for crane #2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67209	13041-10000-07188	350 S GRAND AVE 16TH-22ND FL	90013	9	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	PIN	34.05160512	-118.25169569	RENOVATION OF EXISTING OFFICES. LOCATION IN ELEVATOR LOBBY. NEW LIGHTING FIXTURES AND CIRCUITS. WORK DONE ON 22ND AND 16TH FLOOR. TOTAL AREA 820 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67210	14041-20001-16915	15523 W LEMAC ST	91406	6	189B145   596	2222004007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.21146	-118.47129	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 10 kW(2) SolarEdge SE5000A-US transformerless inverters(40) Renesola JC250M-24/BB pv modules(40) SolarEdge P300 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67211	10041-10000-10910	2666 W OLYMPIC BLVD	90006	1	129B197   273	5076009005	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	10/25/2010 12:00:00 AM	ADDRESS	34.0522	-118.28994	Ti in a Skin Care Clinic. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67212	11041-20001-08187	2029 S CENTURY PARK EAST 38th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			Corrections Issued	08/14/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375		N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67213	18041-10000-05132	827 N VINE ST	90038	13	141B185   126	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.08598	-118.32689	PC for new FA system in three story building. Installing 66 devices, one annunciator and one FACP panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67214	16041-20000-42067	20426 W ARBELLA PL	91326	12	216B109   220	2701082034	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.29251	-118.57898	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67215	17041-10000-03145	2049 S CENTURY PARK EAST 7TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	01/31/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENRGY ONLY TO INTERIOR RENOVATION OF CORRIDORS ON THE 7TH FLOOR. AREA IS 330 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67216	13041-20000-15443	10777 W SANTA MONICA BLVD	90024	5	129B153    23	4325030001	[Q]RD1.5-1-O, [Q]RD1.5-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM	08/07/2013 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	PIN	34.05246051	-118.43369709	UPGRADE EXISTING GENERATOR TO NEW 150KVA. NO NEW CIRCUIT UNDER THIS APPLICATION. REPLACE EXISTING PANELS AND RECONNECT CIRCUITS. PLAN CHECK FOR NEW GENERATOR AND ATS AND SOME NEW WIRING. EXISTING LOADS TO REMAIN. CHANGE FROM SINGLE PHASE TO THREE PHASE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67217	13041-20001-17547	14200 W ARMINTA ST	91402	6	189B153   990	2212001017	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	34.21268	-118.44283	(((CHANGES MADE TO APPROVED SET. THIS PLAN CHECK COVERS THE CLOUDED AIC RATING CHANGES ONLY))))Plan check for food processsing facility. Class II Division 2 Group G Classified Area (Hazardous). Addition of new process line. Load is over 400A at 480V line to line.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67218	18041-10000-29182	108-110 S ROBERTSON BLVD	90048	5	138B169   393	4334005003	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM			PC Approved	08/03/2018 12:00:00 AM	ADDRESS	34.07492	-118.3836	TI IN AN EXISTING RETAIL AREA, SUITE 108 AND 110. T-24 ENERGY ONLY.BLDG PERMIT# 18016-10000-01457	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67219	14041-20000-23466	12209 N GERALD AVE	91344	12	216B137    65	2609014023	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.29156	-118.49198	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER. SYSTEM USES POWER OPTIMIZERS. TOTAL OF 23 MODULESFIRE DECLARATION SIGNED PER REQUIREMENT NO. 96	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67220	16041-20002-42216	3364 N STONERIDGE LANE	90077	4	159B149   307	2278032016	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			PC Approved	12/22/2016 12:00:00 AM	ADDRESS	34.13187	-118.45838	"Revisions to approved plans.  Specified battery capacity changed from 11.6 kWh to 7.7 kWh.  Delta-1 revisions only.  ""0$ plan check fees due to senate bill 1222"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67221	16041-10000-40447	537 S BROADWAY	90013	14	129A211   120	5149033003	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.04731	-118.25166	PC FOR A NEW FIRE ALARM SYSTEM FOR AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES 137 FA DEVICES, AND 7 FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67222	18041-10001-09092			1	150A229   217	5492005010	RD1.5-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM				change to approved set of plans to match installed conditions. bus size was 800amp now 600amp. changes is titled delta 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67223	19041-10000-06319	11111 W SANTA MONICA BLVD suite 1120	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.04771	-118.44481	pc t-24 for Interior tenant improvement to existing office including new partition and suspended ceiling. scope of work 2142sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67224	15041-10000-26357	15320 W CABRITO ROAD	91406	6	189B145   719	2222001007	M1-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.21558	-118.46689	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVING EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67225	15041-20000-29857	12186 W VENTURA BLVD	91604	2	162B165   207	2369004042	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.14315	-118.3981	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 652 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67226	14041-10000-31596	13263 W VAN NUYS BLVD	91331	7	207B157   309	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Info Complete	11/25/2014 12:00:00 AM	ADDRESS	34.26605	-118.42245	Title 24 plan check only. Tenant improvement for a commercial site (Speedy Cash; no change of use). Total indoor lighting area = 2,982 sq. ft. Calculations were done on the 2008 forms. Square footage may change after recalc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67227	16041-10000-09820	12679 W SUNRISE PL	90094	11	102B161  1275	4211037031	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	33.97664	-118.41418	PV1 INSTALL NEW 3.00 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(8 )   AC PVMODULES  SUNPOWER SPR-X20-250-BLK-B-AC AND AN AC MODULE SUPERVISOR.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67228	16041-10000-01152	700 WORLD WAY Term. 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR POWER ONLY. SCOPE INCLUDES ADDING 4 NEW POWER DISTRIBUTION PANELS TO EXISTING BUSWAYS AT LAX TERMINAL 7.  ALSO ADDING 5 NEW MOTOR CONTROL PANELS (MCP-108, 116, 117, 118, & 122) FOR NEW CONVEYORS, AND NEW MOTORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67229	17041-20000-07640	7404 N TROOST AVE	91605	2	186B169   679	2316014031	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.20502	-118.38649	Plan check for a PV1 roof-mounted PV system. System consists of (1) inverter and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67230	15041-10000-00858	10920 W LINDBROOK DR	90024	5	132B153   323	4363023034	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM			PC Approved	03/04/2015 12:00:00 AM	ADDRESS	34.05937	-118.44501	TI to (E) 2-story commercial office building suite.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67231	17041-10001-32602	15920 W ALCIMA AVE	90272	11	129B125   235	4420003007	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			Corrections Issued	02/01/2018 12:00:00 AM	ADDRESS	34.05137	-118.53285	Supplementel for changes to approved set. Changes include addint 200A load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67232	17041-10000-45384	712 S OLIVE ST	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	03/26/2021 12:00:00 AM	ADDRESS	34.0462	-118.25568	PC FOR A NEW FIRE ALARM SYSTEM FOR A CORE AND SHELL  BUILDING. SCOPE INCLUDES 262 FA DEVICES AND 10 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67233	16041-10000-39888	8950 N LAUREL CANYON BLVD	91352	6	195B165   243	2629019016	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.23234	-118.40382	Remove HID Fixtures and replace with new LED fixtures. Total sqft = 24050.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67234	13041-10001-29546	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			PC Approved	05/02/2014 12:00:00 AM	ADDRESS	34.0346	-118.45665	((5/2/2014- CHANGES MADE TO APPROVED SET. RELOCATING FACP. THIS IS A PLAN CHECK ONLY APPLICATION)))NEW FIRE ALARM SYSTEM TO PROVIDE 24 HOUR SYSTEM MONITORING TO SPRINKLER SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67235	16041-10000-26957	540 N LA BREA AVE	90036	5	141B181   962	5525020124	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.08146	-118.34385	PC FOR ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA (OUTDOOR)9484 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67236	12041-10000-09337	5168 E HUNTINGTON DR SOUTH	90032	14	144A235   165	5219001030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.01	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.08911	-118.16978	PLAN CHECK POWER AND ENERGY MARKET BLDG. TWO 600A SERVICES SUPPLYING BUILDING. MODIFICATION TO SEPERATE FIRE ALARM AND TWO SERVICES FROM UTILITY HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67237	18041-10000-26194	16553 W RINALDI ST	91344	12	213B137   493	2610014006	A1-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.27947	-118.49312	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67238	14041-20000-23873	5311 E BUCHANAN ST	90042	1	154-5A227 119	5478009010	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	01/29/2015 12:00:00 AM	ADDRESS	34.11851	-118.20056	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(14) SUNPOWER 327W MODULES(1) POWER ONE PVI-4.2-OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67239	14041-10000-07440	100 S ROBERTSON BLVD	90048	5	138B169   373	4334005002	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	34.0751	-118.38359	THIS IS A ONE STORY RETAIL TITLE 24 AND EMERGENCY LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67240	15041-10001-16416	11818 W WILSHIRE BLVD UNIT 300-PHASE 4	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.0474	-118.46308	update layout. no other changes	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67241	18041-20000-23616	7430 N WISCASSET DR	91304	12	186B085   156	2017036016	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Issued	08/16/2018 12:00:00 AM	ADDRESS	34.20756	-118.65971	Plan check for a PV1 ground-mounted PV system. System size is 7.68 kWac and consists of (32) micro-inverters, (32) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67242	15041-20001-10100	1454 W 66TH ST	90047	8	102B193   250	6015016014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	33.97904	-118.30206	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (22) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67243	18041-20000-31858	8341 N KELVIN AVE	91306	3	192B109   943	2780005069	(T)(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	34.22149	-118.58652	PV1.  Install  5.51 kW DC/5 kW AC roof mounted grid tied PV system.  (19) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67244	12041-10000-21824	10327 N KEOKUK AVE	91311	12	204B113    95	2707016010	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	ADDRESS	34.25844	-118.57438	Plan check for new 10.56KW roof mounted photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67245	15041-20000-08533	6344 N TOPANGA CANYON BLVD #1050	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	10/09/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	"Plan check for power and energy for first time tenant (new restaurant = Tender Greens). Total area: 3177 sq ft. Part of Building A of ""Westfield Topanga"" mall."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67246	16041-20000-42924	11050 W HARTSOOK ST	91601	2	171B173   783	2353007009	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			12/07/2016 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	04/05/2020 12:00:00 AM	ADDRESS	34.1638	-118.3723	Plan check for power and energy. NEW 3-STORY TYPE V-A, 48-UNIT APARTMENT BLDG OVER 2-LEVEL BASEMENT TYPE 1-A GARAGE. 15 typical units. New 1600A service. T24 area: indoor-31,321sqft; outdoor-2,192sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67247	13041-10000-07157	3630 W WATT WAY	90089	8	118-5A201  14	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/19/2013 12:00:00 AM	06/12/2013 12:00:00 AM		Permit Finaled	12/01/2014 12:00:00 AM	ADDRESS	34.02062	-118.28738	NEW CONSTRUCTION. FIRST TIME TENANT OF A SMALL CAFE. FULL PLAN CHECK FOR POWER AND ENERGY. TOTAL AREA 1975 SQ FT.  PLAN CHECK CAN BE DONE ON COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67248	18041-10000-26185	21521 W GAULT ST	91303	3	183B105   431	2138009001	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.19929	-118.59982	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67249	13041-20000-35351	3725 N BEVERLY RIDGE DR	91423	4	162B149   454	2274016008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2013 12:00:00 AM	01/10/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	34.13853	-118.44734	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10.8 KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67250	16041-10000-44906	910 S BROADWAY 2nd Floor	90015	14	127-5A209 260	5139002017	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.04197	-118.25618	Plan check for title 24 only in existing office T.I. Total area: 2770 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67251	18041-20000-05844	7220 W FOOTHILL BLVD	91042	7	202-5A199 526	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.24854	-118.28909	CHANGE OF USE FROM (E) RETAIL TO (N) PHARMACY.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67252	18041-20000-32117	14729 W ROUND VALLEY DR	91403	4	162B149   116	2276034030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	10/17/2018 12:00:00 AM	ADDRESS	34.14374	-118.45309	PV1.  Install 6.22 kW DC/6.06 kW AC-CEC roof mounted grid tied PV system.  27 kWh energy storage system.  (20) modules with microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67253	16041-10001-15225	5248 W SANTA MONICA BLVD	90029	13	144B193   736	5537020029	[T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Info Complete	05/17/2016 12:00:00 AM	ADDRESS	34.09066	-118.30494	This PC is to replace LOST master plan. Scope of work and total area remain the same. <<Plan check for Title 24 only for existing retail Bakery. Total area: 730 sq ft.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67254	12041-10000-29351	940 S CROCKER ST 101-106	90021	14	124-5A211 190	5132002035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.03519	-118.24991	new construction of 10 small typical wholesale tenant spaces on the first floor with roof parking and small office	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67255	15041-10000-29710	9901 W WASHINGTON BLVD Ste 104	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.02174	-118.39786	TI-24. PC FOR ENERGY ONLY. TI FROM A RETAIL TO A RESTAURANT. TOTAL AREA IS 1347 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67256	18041-20000-42366	8046 W OKEAN TER	90046	4	156B173   296	5570019033	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	12/22/2018 12:00:00 AM	ADDRESS	34.12433	-118.37302	Plan check for a PV1 roof-mounted PV system. System size is 19.36 kWdc/15.2 kWac and consists of (2) inverters, (49) modules, and (1) load center.Note: Permit fee due to CA Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67257	16041-20000-20778	525 S FLOWER ST 1st Floor	90071	14	130-5A209 135	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.05109	-118.25696	Plan check for Title 24 only new kiosk outdoor existing high-rise. Total in door and outdoor area: 433.5 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67258	19041-20000-14632	3813 W RONDA VISTA PL	90027	4	150B201  1138	5433009035	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.10477	-118.27596	addition of (4) tesla powerwalls rated 5KW each to an existing pv system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67259	18041-30000-35662	350 S GRAND AVE #3950	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM			PC Info Complete	09/18/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	PLAN CHECK FOR T24 ONLY, TENANT IMPROVMENT TO THE (E) OFFICE SPACE, TOTAL AREA UNDER THE SOW IS 3,055 SQ.FT(B# 18016-20000-29466)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67260	14041-20000-13344	19930 W VENTURA BLVD	91364	3	174B113   434	2164001041	(Q)C4-1VL, (Q)C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.17196	-118.56707	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT: TO (E) RETAIL. NEWLY CONNECTED LOAD < 400 AMPS. 1366 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67261	11041-20000-27641	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	Existing juice bar space.  Juice bar (Surf City Squeeze) will now be the new tenant.  New load does not exceen 400 AMPS.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67262	18041-20001-44745	2759 N CASIANO ROAD	90077	5	156B145   224	4378031030	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.12321	-118.47144	Expedite fee.PV1.  Install 13.53 kW DC roof mounted grid tied PV system.  (41) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67263	16041-20000-13417	13630 W PAXTON ST	91331	7	210B157   515	2619001031	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.27081	-118.42985	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER STANDARD PLAN. SYSTEM SIZE: 3.64 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67264	19041-10000-34188	960 W 7TH ST	90017	14	129A207    16	5144009079	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	03/13/2020 12:00:00 AM		Permit Finaled	05/31/2023 12:00:00 AM	PIN	34.04918918	-118.26209882	Plan check for a methane detecting system located in a high rise building. Scope inlcudes (2) control panels, (1) communication panel and (51) communication devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67265	07041-10002-03100	13520 W VAN NUYS BLVD	91331	7	207B157   939	2620014901	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM			PC Info Complete	08/27/2010 12:00:00 AM	ADDRESS	34.26189	-118.42756	NEW 2-STORIES OFFICE BUILDING / 1-STORY COMMERCIAL BUILDING WITH COMMOM  SUBTERRENEAN PARKING(((((((((((((((((((((((((((  change of switch gear out door pull section vent per DWP requirement. 8-27-2010   )))))))))))))))))))))))))))))))))). This is recognized as obe bldg and disconnects are grouped.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67266	15041-20000-43280	960 N LA BREA AVE	90038	4	144B181   634	5531015004	(Q)M1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Closed	11/14/2018 12:00:00 AM	ADDRESS	34.08868	-118.34386	PC FOR A NEW FIRE ALARM SYSTEM ON EXISTING 5 STORY BUILDING. SCOPE INCLUDES 135 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67267	12041-10000-20672	1515 N WILCOX AVE	90028	13	147A187   100	5547017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.09849	-118.33114	TENANT IMPROVEMENT IN A SMALL RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67268	13041-20000-22320	1639 N SILVER LAKE BLVD	90026	13	144A205   247	5425017002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.08908	-118.26897	PC FOR T24 ENERGY ONLY. TOTAL AREA 2500 SQ FT. COFFEE SHOP, RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67269	13041-10000-20618	1156 W 36TH PL	90007	8	120B197  1046	5040030012	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/02/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.02189	-118.29333	pc for power only. SERVICE UPGRADE (600A) AND APT PANELS UPGRADE (16x 60A).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67270	15041-10000-42294	200 S LOS ANGELES ST 1-104	90012	14	130-5A213 175	5161024014	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM			PC Info Complete	12/16/2015 12:00:00 AM	ADDRESS	34.05007	-118.2433	INSTALLING  AN 800A DISTRIBUTION BOARD  AND PANEL BOARDS FOR 3 TENANT SPACES; INSTALLING LUMINAIRES INTHE ELECTRICAL ROOM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67271	12041-10000-20407	17227 W HEMMINGWAY ST	91406	6	189B133   613	2204011003	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.21357	-118.50872	ROOF (SFD)  INSTALLATION  OF 6.8KW PHOTOVOLTAIC SYSTEM- 1 INVERTER AND 21 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67272	13041-20000-33233	1639 N SILVER LAKE BLVD	90026	13	144A205   247	5425017002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.08908	-118.26897	PC FOR T24 ENERGY ONLY. TOTAL AREA 2500 SQ FT. COFFEE SHOP, RETAIL. new submittal for changes.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67273	12041-20000-17689	6420 W WILSHIRE BLVD 18TH FLR	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM			PC Approved	07/30/2012 12:00:00 AM	ADDRESS	34.06365	-118.36922	T.I. to a high rise building on 18th floor.  Install new and relocate some lights.  Plan check for energy only.Note: Permit issued under 12041-20000-15703	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67274	12041-10000-01060	1900 S AVENUE OF THE STARS level# A	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Approved	01/17/2012 12:00:00 AM	ADDRESS	34.05979	-118.41671	TI for a cofference room. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67275	15041-20000-17209	744 S HARTFORD AVE 1-24	90017	1	130-5A205 272	5143010008	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			06/04/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.05099	-118.2679	Plan check for new 24 unit 4 story appartment with 1,200A Service.  Fire alarm variance has been approved.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67276	16041-20000-15645	23020 W ELKWOOD ST	91304	12	189B097   843	2014028015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.21247	-118.62861	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (21) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67277	16041-20000-12032	11044 W MAGNOLIA BLVD	91601	2	171B173   608	2353006013	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM			PC Approved	04/06/2016 12:00:00 AM	ADDRESS	34.16478	-118.37205	Plan check for energy only. Change of use from ex. retail to restaurant. TI, adding new lighting to kitchen area. 296sqft. Permit pulled under permit application #16041-20000-08170	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67278	12041-10000-03976	770 W WILSHIRE BLVD 3RD FLOOR	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			Corrections Issued	02/22/2012 12:00:00 AM	ADDRESS	34.04914	-118.25811	RETROFITTING EXISTING 112 2X4 FIXTURES WITH LED RETROFIT KIT ON 3RD FLOOR OF 9 FLOOR BUILDING. ENTIRE 3RD FLOOR (NO SUITE NUMBER).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67279	15041-10000-39393	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Expired	12/25/2017 12:00:00 AM	ADDRESS	34.09815	-118.32564	T-24, Pc for energy only to existing offices. Installing new lighting and receptacles. sq ft = 2625	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67280	14041-20000-06509	5722 N EL CANON AVE	91367	3	174B089   198	2046006023	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.17467	-118.65111	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67281	13041-10001-27146	10226 N BETTY LOU LANE	91042	7	204A197   153	2558034003	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.25491	-118.30019	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67282	17041-20000-45030	22119 W VALERIO ST	91303	3	186B101   596	2023013016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Issued	12/28/2017 12:00:00 AM	ADDRESS	34.20479	-118.6088	"'38$ fee due to senate bill 1222""Plan check for solar pv system w/roof-mounted array on SFD.11.52kW ungrounded system. (36) 320W AC modules.Derating main breaker to 175A."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67283	17041-10000-11044	11700 W MAGNOLIA BLVD	91607	2	171B169   419	2355005061	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			04/05/2017 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	10/24/2021 12:00:00 AM	ADDRESS	34.1647	-118.38801	Plan check for power and Title 24. New 3 story 19 unit apartment building over grade level parking garage.  New 1,200 amp 120/208 volt service.  34,023 sq. ft. common area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67284	18041-20000-21375	10201 S LA CIENEGA BLVD	90045	11	090B173   191	4129031017	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	33.94379	-118.37026	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67285	18041-20000-06374	4643 W VANTAGE AVE	91607	2	168B165   778	2356036027	R1-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	02/21/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	PIN	34.15531123	-118.3979661	Plan check for the addition of (3) Tesla PowerWalls onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67286	17041-10000-35962	2326 S RIDGELEY DR	90016	10	123B177   455	5063020900	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.03535	-118.36037	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67287	13041-10000-24998	7430 N MAMMOTH AVE	91405	2	186B157   299	2215004009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.2057	-118.43242	PV1. ROOF MOUNTED SOLAR ARRY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 3 KW. TRANSFORMERLESS WITH 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67288	16041-20000-30267	9280 W NIGHTINGALE DR	90069	4	150B169  1384	5561007023	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.10343	-118.39095	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 30KW INTERCONNECTED WITH MSP.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67289	16041-10000-00678	2007 S HARCOURT AVE	90016	10	126B181  1397	5061017029	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2186.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.03819	-118.34313	PV 1 roof mouted installation to a single family home. Microinvertor total rating: 2.85 kw, (10) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67290	14041-20000-07406	6515 N DE SOTO AVE	91303	3	180B109   551	2148026040	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.18909	-118.58873	T.I. to existing building, place of assembly.  Install new subpanel and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67291	16041-10000-45181	200 N SPRING ST 10TH FLR	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.05405	-118.24317	PC FOR OFFICE TI. UPGRADING LIGHTING AND ADDING PARTITIONS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67292	14041-20000-05226	5824 S WEST SEAGLASS CIR	90094	11	102B157   400	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	33.97371	-118.41951	ROOF-MOUNTED,PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67293	17041-10000-11575	243 E 50TH ST	90011	9	111A205   264	5109008003	RD1.5-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	33.99759	-118.2713	PC FOR PV SYSTEM ROOF MOUNTED. 3KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67294	10041-10000-06253	12015 E WATERFRONT DR 2nd Floor	90094	11	105B165   916	4211011032	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Public Safety Only			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/24/2010 12:00:00 AM	PIN	33.9832223	-118.40406817	Plan check for new installation of FM 200 Pre-Action system for USC Computer equipment room building 4 2nd Floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67295	15041-20000-01301	14511 W DAUBERT ST	91345	7	207B149    96	2615027019	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.26716	-118.44875	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.  (22) CANADIAN SOLAR CS6P-235/250 MODULES(1) SOLAREDGE SE5000A INVERTER(22) SOLAREDGE POWER OPTIMIZERS P300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67296	18041-10000-04963	3444 E WHITTIER BLVD	90023	14	121-5A227 171	5188017004	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Issued	10/11/2018 12:00:00 AM	ADDRESS	34.02706	-118.1997	PC FOR A NEW 600A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD FOR AN EXISTING MEDICAL FACILITY. REFEEDING EXISTING PANELS TO NEW SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67297	17041-20002-18440	11824 N STEWARTON DR	91326	12	216B121   372	2872023018	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2017 12:00:00 AM			PC Approved	07/05/2017 12:00:00 AM	ADDRESS	34.2874	-118.54009	[[[7/5/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGING THE INVERTER OUTPUT FEEDER TO #6 ]]]]pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67298	12041-10001-04924	19310 S PACIFIC GATEWAY DR	90502	15	057B197     9	7351031030	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM			Reviewed by Supervisor	03/15/2013 12:00:00 AM	ADDRESS	33.85616	-118.29473	[[[[[[[[[[[ Changes to original plans (Behrooz). Plan check for lighting and power. Addion of 19542 sqrft of office space. Also some improvements to the warehouse.]]]]]]]]]]]]]New warehouse/distrbution building with office space on 2 floors.  Plan check for Power and Energy.  (((Applicant has a pre-printed check, additional fees will need to be collected.  424,349 sq ft for Energy, etc))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67299	19041-20000-23994	7119 N POMELO DR	91307	12	183B089   185	2028041010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.19962	-118.64942	Plan check for Energy storage sytem in to existing PV system. Energy storage system size: 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67300	18041-10000-11208	6523 W HOLLYWOOD BLVD SUIT 3	90028	13	148-5A187 109	5547007012	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.10175	-118.33175	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO NEW RESTAURANT. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. A-OCCUPANT LOAD > 100. TOTAL AFFECTED AREA IS 2951 SQ. FT. B#17016-10000-06324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67301	16041-30000-28615	2029 S CENTURY PARK EAST 15th Floor-Restroom	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check Title 24 only in existing high-rise men and women restroom on 15th floor. Total lighting area: 380 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67302	16041-10000-09740	14732 W WEDDINGTON ST	91411	4	172-5A149 181	2249019018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2016 12:00:00 AM	03/21/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.16652	-118.45428	PV1, rooftop solar installation with AC modules (22) SPR-E20-327W-C-ACStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67303	12041-20000-27916	333 S HOPE ST 3760	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Approved	11/20/2012 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for energy and emergency lighting. 2910 sqft. 37th floor. Suite 3760.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67304	14041-10002-15887	8018 W BEVERLY BLVD	90048	5	138B177   470	5511003023	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.07593	-118.3645	CHANGES TO APPROVED SET OF PLANS. REVISED NUMBER OF DEVICES. UPDATED FLOOR PLANS AND BATTERY CALCS. REVISED DEVICE TYPE. permit for addition of 3 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67305	19041-20001-36196	12033 N LONGACRE AVE	91344	12	216B125   408	2601031039	(T)(Q)RE40-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2019 12:00:00 AM			PC Approved	09/20/2019 12:00:00 AM	ADDRESS	34.2896	-118.53069	9/20/19CHANGES TO APPROVED SET DOWNSIZE THE MAIN BREAKER.<<<PLAN CHECK FOR NEW PV ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 22.68KW DC/19.28KW AC. SCOPE OF WORK CONSISTS (63) PV MODULES WITH OPTIMIZERS, (2) 11.4KW INVERTERS, AND (2) SUB PANELS>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67306	18041-20000-22398	15928 W VENTURA BLVD Suite 108	91436	5	168B141   621	2283010033	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM			PC Approved	06/15/2018 12:00:00 AM	ADDRESS	34.15566	-118.48041	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from yoga to nail salon/tenant improvement. Total lighting area = 1,652 sq. ft.Note: Building application has been generated under 18016-10000-17128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67307	18041-20000-27694	6036 N RHODES AVE	91606	2	177B165   589	2333014019	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	08/24/2018 12:00:00 AM	ADDRESS	34.18059	-118.40289	Plan check for PV roof mounted system addition to existing system(8.8KW AC). Addition system size: 7.2KA  AC with 29 AC modules.  Total existing and new system size: 16 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67308	17041-20001-19512	5518 N KEOKUK AVE	91367	3	174B113   333	2151012073	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM			PC Approved	06/26/2017 12:00:00 AM	ADDRESS	34.17291	-118.57458	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12.4 kWac and consists of (36) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67309	13041-10000-09243	12325 N LONGACRE AVE	91344	12	219B125   137	2601075022	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.29347	-118.53501	PV1 SINGLE FAMILY DWELLING. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 8.33 kW. TRANSFORMERLESS INVERTERS WITH POWER OPTIMIZERS. [INVERTER: SOLAR EDGE SE3800A-US] [SOLAR MODULES: TRINA SOLAR TSM 245PC05/PA05.18]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67310	18041-30000-19104	1070 S BEDFORD ST 1-19	90035	5	132B169   448	4332021027	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.0573	-118.38026	NEW FIRE ALARM SYSTME FOR A NEW 19-UNIT, 4-STORY APARTMENT BUILDING. (1) FACP, (111) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67311	15041-20001-32029	4300 N RHODES AVE	91604	2	165B165   658	2367002012	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.14874	-118.40289	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 46 MODULES. SYSTEM USES POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67312	15041-10000-07055	200 WORLD WAY # 226	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR ENERGY. INSTALL ILLUMINATED SIGNAGE NOT VISIBLE FROM  ROW. TOTAL AREA 75.125 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67313	18041-10000-06593	10250 W SANTA MONICA BLVD S2680	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Issued	03/15/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full Plan check for New stoage space #S2680 within Westfield Century City. This is for core and shell only. Total area: 525 sq.ft. This SOW is under the landlord's plan.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67314	12041-20000-30346	9901 W WASHINGTON BLVD	90232	5	120B165  1311	4207004034	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM	01/07/2013 12:00:00 AM		Permit Expired	02/02/2015 12:00:00 AM	ADDRESS	34.02174	-118.39786	Delta 5 modification to previously approved set of plans which includes installing a 30 hp fire pump and modification to the retail circuit breaker trip setting at MSA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67315	16041-20001-15173	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	33.79072	-118.29449	[[[5/3/17 CHANGES TO APPROVED T24 ONLY. CHANGES TO THE OUTDOOR FIXTURE TYPE ]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67316	11041-20000-15910	20940 W BURBANK BLVD	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	03/05/2013 12:00:00 AM	ADDRESS	34.17302	-118.58923	New UPS system, new panel, additional ckts added for Kaiser MOB. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67317	16041-30000-38093	5235 W 104TH ST	90045	11	090B173   250	4129032012	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	33.94208	-118.37155	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67318	10041-10000-13859	750 N HILL ST	90012	1	135A215   384	5408020003	C2-2	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Expired	04/05/2013 12:00:00 AM	ADDRESS	34.06203	-118.2397	"T.I. to existing restaurant (Ocean Seafood).  Install general and emergency lights in dinning, to-go, bar, and waiting areas.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date08/22/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67319	15041-20000-14305	6100 W CENTER DR Suite 1275	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	33.97733	-118.3922	Title 24 plan check only.  Total area = 3,280 sq. ft.  T.I. to existing commercial highrise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67320	16041-20000-10896	321 E 2ND ST 5TH FLOOR	90012	14	129A213    70	5161017009	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	ADDRESS	34.04905	-118.24106	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVMENT ON 5TH FLOOR:   (2) NEW OFFICES. 914 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67321	11041-10000-14252	500 W 7TH ST	90014	14	129A209   182	5144012055	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			Corrections Issued	07/08/2011 12:00:00 AM	ADDRESS	34.04651	-118.25582	T.I.  Existing 7-11.  Replacing light fixtures from fluorescent to LED on the retail floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67322	16041-20000-26442	11025 N SUNNY BRAE AVE	91311	12	210B109   125	2707033061	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.2707	-118.58063	Plan check for PV roof mounted system. System size: 8.4kW with 30 modules and 30 micro-inverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67323	14041-10000-31502	351 N AMALFI DR	90402	11	123B129   451	4410024011	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.03334	-118.51314	PV1.  Install 6.21 kW roof-mounted, utility-interactive PV system.  6 kW transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67324	16041-10000-13189	2656 N GRIFFITH PARK BLVD 6	90039	4	150A205    85	5434037020	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.10657	-118.27197	PC for energy only to an existing ice cream shop, adding and relocating lighting. Total sq ft = 741. new water heater	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67325	14041-10001-24545	5008 N TILDEN AVE	91423	4	171A151   222	2248008040	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			Reviewed by Supervisor	09/16/2014 12:00:00 AM	ADDRESS	34.16155	-118.44735	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 12240 W DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(48)MODULES: SUNIVA OPT 265-60-4-100(2) INVERTER(S): SMA AMERICA SB6000US>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67326	14041-20000-24664	8234 W 4TH ST	90048	5	138B173  1197	5511042029	R2-1-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.07061	-118.3686	PV1Central/String inverter simplified standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 8.6kW.(1) ABB Uno-8.6-TL-OUTD-S-US-A transformerless inverter(33) Hundai HiS-S270RG pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67327	12041-20000-30188	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM			PC Approved	12/14/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Change to lighting in an existing restaurant space.  Load is less than 400 amps and occupancy load is less than 99 people per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67328	18041-10000-34314	1660 W 221ST ST	90501	15	048B193   477	7346018002	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	10/19/2018 12:00:00 AM	ADDRESS	33.82667	-118.30852	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.68KWdc / 8.28KWac. (24)MODULES- SUNPOWER SPR-X21-345-D-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67329	13041-10000-34670	6179 E ST ALBANS ST	90042	14	157-5A231 342	5483016023	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.12459	-118.18455	PV1, Install 4.25 kw DC roof-mounted solar array for a residential house , interconnect with main panel, (1) transformerless inverter[SOLAREDGE SE5000A-US(240V)] and (17) modules[RENSOLA JC250M-24/BB]. With  power optimizer[SOLAREDGE]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67330	13041-10000-21827	13645 W RIVERSIDE DR GYM	91423	4	168B157   235	2359019007	R1-1, RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.15777	-118.43065	New fire alarm system for Notre Dame High School gymnasium modular building.  9 devices and one new fire alarm control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67331	19041-20000-00203	3616 S MAPLEWOOD AVE	90066	11	111B149   302	4245011008	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.00273	-118.44688	Plan check for PV roof mounted system, System size: 3.54kW with 12 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67332	16041-10000-11292	12655 W BLUFF CREEK DR	90094	11	102B161  1281	4211037037	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	33.97565	-118.41332	New F.A. system on a (N) apartment build. site on METHANE ZONE.  (1) F.A. Panel     (1) Comm. Panel     (345) devces***Modification has been filed, and Conduit Only is filed under 16041-90000-09221	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67333	10041-10000-04434	7630 N VAN NUYS BLVD	91405	6	186B149   111	2215028021	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Public Safety Only			03/11/2010 12:00:00 AM	03/11/2010 12:00:00 AM		Permit Finaled	09/27/2010 12:00:00 AM	ADDRESS	34.20936	-118.44853	installation of fa system to monitor tamper/ water flow switches  and fa devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67334	12041-20000-24475	21902 W LASSEN ST	91311	12	201B101   162	2746017030	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02, 1132.13	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.24976	-118.60494	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67335	18041-10000-38543	201 N FIGUEROA ST 2nd Floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/12/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.05859	-118.25142	T-24 TENANT IMPROVEMENT WORK ON  14,086 SQ FT  NEW WALLS, WORK INCLUDES POWER AND LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67336	19041-10000-38394	3560 S WASATCH AVE	90066	11	114B153   799	4246010017	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.00789	-118.43954	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10.065KWdc/10KWac. SCOPE OF WORK IS 33 MODULES (DUCAL SOLAR TECHHONOLGY LLC) WITH OPTIMZERS (SE P320) AND A CENTRAL INVERTER (SE10000H-US), CONNECTED TO A 400A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67337	14041-10000-06008	20315 W NORDHOFF ST	91311	12	195B113    61	2781001019	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.23201	-118.57642	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE FROM WAREHOUSE TO CHILDREN PLAY GROUND. SERVICE IS EXISTING. FIRE ALARM UNDER SEPERATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67338	18041-20000-46959	8220 N DE SOTO AVE	91303	3	225B157   282	2510012019	(T)(Q)RD1.5-1, P-1VL, [Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Sylmar	Sylmar, Winnetka		1342.01	Electrical	Electrical	Commercial			12/11/2018 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM				Plan check for title 24 onlyh in existing restauant T.I. dinning Total area: 1000 sq ft. B#18016-20000-33044	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67339	18041-20001-49104	10980 W VERANO ROAD pv1	90077	5	144B145    32	4377023001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.09486	-118.46249	Install roof mounted pv system sized 18.2KW AC interconnected with msp.(2) tesla batteries 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67340	15041-20000-29787	6225 W CENTURY BLVD Floors 3-12	90045	11	090B165     5	4124026005	C2-2, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	05/16/2017 12:00:00 AM	ADDRESS	33.9457	-118.39456	Plan check for power only. Project site is an existing high-rise commercial building (hotel). scope of work is within hotel rooms and corridors. Work includes the addition of branch circuits to the rooms. All panel boards and distribution equipment is existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67341	16041-20000-10438	14757 W ARCHWOOD ST	91405	2	180B173   634	2336002014	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.19306	-118.45495	Plan check for a PV1 roof-mounted PV system. System size is 2.3 kWac and consists of (9) modules and (9) micro-inverters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67342	16041-10000-00802	2336 S SEPULVEDA BLVD	90064	5	126B153  1085	4322021005	M2-1VL	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.03789	-118.43563	Addition to an existing two story animal shelter/office building and change of use to office. PC for energy only, total area: 2,736 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67343	13041-10000-30377	6055 N VAN NOORD AVE	91401	2	177B161   687	2331022021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Expired	11/24/2015 12:00:00 AM	ADDRESS	34.18102	-118.41526	PV1 5KWAC. 240V. microinverter. STD. 1story. Roofmount. [(20) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(20)modules: {SunModule SW-250 mono}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67344	15041-10000-36519	1312 E 112TH ST	90059	15	087A211    53	6070013004	R2	South Los Angeles				2426.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	PIN	33.93301834	-118.25166987	PVI, INSTALL 1.35 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(6) MODULES:TRINA SOLAR TSM-225PA05(6)MICRO INVERTER:ENPHASE ENERGY M215-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67345	16041-10004-29411	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	33.97808	-118.40726	DELTA CHANGES DATED AFTER 1/1/2018 TO THE APPROVED CORE & SHELL PLANS. NOTE CHANGES ON DELTA 233, 221CS AND CS===============Full PC for core and shell alteration. Change of use from airplance hangar to office, 4-level building. Methane zone. All equipment on single line is new, shaded areas on single line to be done under a different scope. Installing (2) new main services medium voltage switchgears. MVSG1 is 3phase 3Wire 2000 Amps. MVG2 is 3phase, 3Wire 2000Amps. New lighting. Total sqft = 375,622 (Applicant assumption). ** Note Title 24 form have not yet been provided.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67346	18041-10000-48990	8231 N WOODMAN AVE	91402	6	192B153   835	2213016021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.22033	-118.43269	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH LED FIXTURES - T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67347	12041-20000-18021	5545 N RESEDA BLVD	91356	3	174B125   482	2160004025	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	08/08/2012 12:00:00 AM		Permit Finaled	10/18/2012 12:00:00 AM	ADDRESS	34.17091	-118.53628	Tenant improvement to existing restaurant.  Replace indoor and outdoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67348	16041-20000-31783	11431 N CLYBOURN AVE	91342	7	213B173   312	2530023004	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.278	-118.374	PV1.  Install 13.08 kW roof mounted PV system on SFD's detached garage.  (40) modules with (2) 6kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67349	15041-20000-35919	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.05048	-118.25755	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 4400.  5759 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67350	14041-20000-23223	801 S FIGUEROA ST 8th floor	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.04789	-118.26153	TI to (E) commercial office space in (E) highrise office building.  Plan check for energy under 2013 Title 24 Part 6 Standards	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67351	13041-20000-22652	6738 W 87TH ST	90045	11	096B161   753	4122018006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Expired	09/15/2015 12:00:00 AM	ADDRESS	33.95846	-118.40813	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW USING 15 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67352	15041-20000-25604	1930 S LONG BEACH AVE EAST UNIT - A	90058	9	118-5A213 351	5167013042	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Closed	09/22/2015 12:00:00 AM	ADDRESS	34.01969	-118.2427	THIS PV SYSTEM IS PERMITTED FOR 27.6KW AC. THIS SYSTEM USES 89 MODULES. 1 INVERTERS TO A MAIN SERVICE. THIS IS PART OF A 2 SYSTEM INSTALLATION. THIS PERMIT SHALL COVER SYSTEM 2 OF 2. THIS IS FOR UNIT A.PLAN CHECK FOR SPLIITING OF THE SYSTEM AND PERMIT FOR SYSTM AMAJORITY OF ORIGIANAL PERMIT FEES HAVE BEEN COLLECTED FOR A DESIGN THAT REFLECTED A COMBINED SYSTEM. THIS PERMIT IS FOR SEPARATION AND ALLOWING INDIVIDUAL INSPECTION FOR THIS SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67353	12041-10000-07372	4501 S FIGUEROA ST 1-21	90037	9	112-5A201 145	5018031003	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	Apartment			03/30/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	07/05/2013 12:00:00 AM	ADDRESS	34.00257	-118.28308	NEW 21 UNIT APARTMENT BUILDING.   FOUR STORIES OVER ONE LEVEL OF GARAGE.  VARIANCE WAS SUBMITTED FOR THE FIRE ALARM SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67354	17041-10000-38349	1307 W SEPULVEDA BLVD # 1	90501	15	042B197   227	7347018089	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	33.8138	-118.2996	CHANGE OF USE FROM RETAIL TO RESTAURANT EPC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67355	17041-10001-10458	555 S MATEO ST Bldg 2-Ste 300	90013	14	126A217    62	5164002012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/07/2018 12:00:00 AM			PC Approved	03/07/2018 12:00:00 AM	ADDRESS	34.03943	-118.23302	Delta 5 changes to lighting system- luminaires wattages remain the same but voltage rating changed.Changes are identified on the revised sheets(((((((((PC FOR POWER AND ENERGY FOR FIRST TIME TENANT.OFFICE SPACE IN COMMERCIAL BLDG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67356	14041-20000-10239	523 W 6TH ST #219	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	PIN	34.04872199	-118.25441618	T.I. FOR SUITE 219. PART OF HIGH RISE. NEW LIGHTING FOR EXISTING OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67357	18041-20002-32273	3070 W LOS FELIZ BLVD	90039	13	157-5A207 257	5435017019	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.12455	-118.26614	4/5/2019changes to an approved set of plans.  changes to reconfigure the lighting fixtures and energy calculations. additional panel and associated circuits.((((Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from bakery/cafe to banquet hall. Work includes a total lighting area of 12,560 sq. ft.Note: Building permit has been issued under 17016-20000-09853. Occupant load is 280.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67358	19041-30000-22262	5001 N FIGUEROA ST Suite D	90042	1	150A225   181	5468004009	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.10521	-118.20218	Plan check for Title 24 only. Project site is a tenant space in an existing commercial building. Project scope is a tenant improvement. Total lighiting area = 1,549 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67359	14041-10001-25708	9763 W SUFFOLK DR	90210	5	159B157   245	4385001026	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			Reviewed by Supervisor	10/07/2014 12:00:00 AM	ADDRESS	34.12924	-118.42896	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 11.73 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(46) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGE SE5000A-US-ZB-U & SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67360	11041-10000-19027	4151 W BEVERLY BLVD	90004	13	138B197   319	5520025006	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM			PC Approved	10/03/2011 12:00:00 AM	ADDRESS	34.07643	-118.2996	T.I. TO AN EXISTING OFFICE AREA FOR GROUP COUNSELING.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67361	12041-10000-29957	17345 W HAMLIN ST	91406	12	180B133   356	2229024003	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	03/21/2013 12:00:00 AM	ADDRESS	34.1886	-118.5116	PV1:  New 5.5 KW  roof mounted PV system.  Installing 25 modules, one inverter, and one enclosure box.  The inverter is transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67362	12041-10001-28747	3000 W 6TH ST 2ND FL	90005	10	135B197  1002	5077008001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	PIN	34.06351748	-118.28745252	Revision to the approved plan. Change the T24, shown with delta 1.  ((((((((((((((((((((((((9TI TO EXISTING RESTAURANT. 4 STORies. work is for 2ND FLOOR)))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67363	19041-20000-43586	5449 E ALHAMBRA AVE	90032	14	139-5A237  32	5220021022	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	04/21/2021 12:00:00 AM		Permit Finaled	05/18/2021 12:00:00 AM	ADDRESS	34.07822	-118.1669	Plan check for Title 24 energy only, new lighting, newly connected load is less than 400A. Total area: 5754 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67364	16041-20000-14668	16604-16608 W ARMINTA ST	91406	6	189B137    44	2205009035	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.21474	-118.49474	PERMIT FEE $0.00 STATE SENATE BILL NO.1222Install a roof-mounted solar array on a commercial building. Interconnect directly to LADWP = FEED-IN-TARIFF System. System size: 60kW [(5) 12kW inverters]. Ungrounded system.(240) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67365	14041-10000-30506	19500-19600 S VERMONT AVE	90502	15	057B197    21	7351033009	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	33.85326	-118.29031	Tenant improvement serving warehouse/office building.  Plan check for power and energy - more than 400A of connected load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67366	16041-20000-44097	15322 W HART ST	91406	6	183B145   396	2234024001	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Apartment			12/15/2016 12:00:00 AM			PC Info Complete	10/20/2017 12:00:00 AM	ADDRESS	34.19734	-118.46707	new apartment building 800amp service.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67367	14041-10000-03071	5800 N VAN NUYS BLVD	91401	4	174B149   301	2245005008	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	06/05/2014 12:00:00 AM	ADDRESS	34.17586	-118.44837	Tenant improvement for Hertz car rental store.  Title 24 plan check for lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67368	10041-10000-04987	7077 W SUNSET BLVD	90028	13	147B181   584	5548013405	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM			PC Approved	03/18/2010 12:00:00 AM	ADDRESS	34.09813	-118.34389	TENANT IMPROVEMENT FOR EXISTING RESTAURANT. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS AND EMERGENCY LIGHTS. PERMIT FOR 24 NEW CIRCUITS WAS ISSUED UNDER 09041-10000-21899.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67369	19041-10000-03390	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	"FIRST TIME TENANT TI ON 2ND LEVEL TO  9TH LEVEL N BUILDING ""C"". CORE & SHELL WAS APPROVED PCAM # E18LA05111. AREA OF SCOPE 293,639 SQFT. COMPLETE PLAN CHECK FOR POWER & ENERGY. BUILDING PERMIT # 18016-10000-23767"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67370	16041-10004-27380	877 S FRANCISCO ST	90017	14	129A207   122	5144023075	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.04791	-118.26383	Supplemental power plan check and supplemental permit to previously approved set. Changes noted as Delta-G, scope includes: adding (3) panleboards, (1) 45kVA transformer, new loads and circuitry.<<Supplemental to changes to previously approved set. Changes due to reduction in project costs. Changing feeders from copper to aluminum and reducing lengths. Changes clouded under delta E.Changes where already assesed by Mehdi, PC to verify and remove this sentence upon approval.>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67371	12041-10000-04024	18041 W CHATSWORTH ST # 11	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			PC Approved	02/22/2012 12:00:00 AM	ADDRESS	34.26482	-118.52585	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR A BEAUTY SALON, SPACE #11	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67372	13041-20000-22971	665 W JEFFERSON BLVD	90007	9	120A201    58	5123009017	[Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM			Corrections Issued	08/28/2013 12:00:00 AM	ADDRESS	34.02302	-118.28206	REPLACEMENT OF LIGHTING FIXTURES FOR ENERGY EFFICIENT LIGHTING. PC FOR T24 ENERGY ONLY. NO CHANGE IN EMERGENCY LIGHTING. REPLACEMENT OF EXISTING FIXTURES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67373	18041-10000-38215	750 S LAMAR ST ROADABILIT-CANOPY	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (G) ROADABILITY CANOPY7 OF 10BUILDING PERMIT 13010-10000-02298	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67374	17041-20000-04255	1697 S PACIFIC AVE ROOFTOP-BAR 2	90291	11	106-5A143  43	4226009020	C2-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Issued	04/24/2017 12:00:00 AM	ADDRESS	33.98722	-118.47211	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR NEW ROOFTOP BAR. PHASE 3. NOT A HIGHRISE PER APPLICANT. NEWLY CONNECTED LOAD < 400 AMPS.  290 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67375	19041-10000-46103	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	Adding 44 new devices to an existing Fire Alarm System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67376	17041-20002-45762	14101 W PIERCE ST	91331	6	201B153   465	2644005032	RS-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM			Corrections Issued	04/19/2018 12:00:00 AM	ADDRESS	34.24748	-118.44057	Supplemental for changes to approved set. Installing additional solar disconnect and adding fuses to Powerwall disconnect. Relocated main panel, ac disconnect, load center and gateway panel location. All changes clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67377	19041-10000-16125	1256 W 7TH ST roof	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.05216	-118.26774	ADDITION OF PANEL BOARD AND CICUITS FOR POOL DECK AREA , BAR AND STORAGE AREAPLAN CHECK IS FOR TITE 24 INDOOR AND OUTDOOR LIGHTING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67378	15041-10000-29561	6540 W HOLLYWOOD BLVD	90028	13	148-5A187 184	5547016005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	02/12/2024 12:00:00 AM	ADDRESS	34.10142	-118.33231	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67379	15041-20000-41510	9131 N OAKDALE AVE #130	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/09/2015 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.23697	-118.56716	Plan check for title 24 only for T.I. existing space manufacturing/office. Total area:11,473 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67380	14041-20000-04990	16400 W HAMLIN ST	91406	6	180B137   564	2231003013	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Expired	03/30/2016 12:00:00 AM	ADDRESS	34.18824	-118.49041	Roof mounted PV system 2.5KWdc.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67381	18041-20001-39493	10026 N SALOMA AVE	91345	7	204B149   496	2647008005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.25264	-118.45746	Plan check over the counter - revisions to online solar permit standard plan.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67382	18041-20001-48663	10920 W OAK MOUNTAIN PL pv1	91040	7	207B173   514	2528037022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2018 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.26266	-118.36793	expeditepv1install roof mounted pv system sized 12.6KW AC inerconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67383	13041-10001-33044	12450 W TERRA BELLA ST	91331	7	210B165   528	2536021013	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.26843	-118.40378	Expedited RSES plan check per applicant request.[][][]PV1, Install 7.5 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE6000A-US. (30) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67384	12041-20000-16891	6430 W SUNSET BLVD	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM			PC Approved	07/25/2012 12:00:00 AM	ADDRESS	34.09782	-118.32979	T.I. to a high rise building on 15th floor of suite #1506.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-10000-14064	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67385	12041-10000-15293	600 W 7TH ST	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	08/01/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	"14 NEW PANELS/SUBPANELS AND TRANSFORMERS FOR A ""DATA CENTER"".  Per applicant, NO LOADS will be installed and loads will only be added as data space is rented out.  A permit will need to be installed for each separate branch circuti that is pulled.  Full Plan check.   Server Equipment has dual cords with an internal transfer switch so panel loads are calculated at 50%."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67386	15041-20000-14776	1900 N VISTA ST	90046	4	150B181   474	5572026003	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Refund in Progress	05/16/2016 12:00:00 AM	ADDRESS	34.10561	-118.35181	Plan check for a ground-mounted PV system. System size is 16kW and consists of (2) inverters, and (48) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67387	17041-10000-31683	16737 W TUPPER ST	91343	12	198B137   521	2687016022	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.23946	-118.49712	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 3.8KW/AC  4.06KW/DCSCOPE INCLUDES CENTRAL INVERTER WITH 14 MODULES WITH OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67388	14041-10002-15632	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016021	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM			PC Approved	11/30/2015 12:00:00 AM	ADDRESS	34.08758	-118.34425	11/30/15: Changed to approved set: Removed Panel F, Revised Panel E, Enlarged area of the juice bar.                   Permit under 14041-10000-15632((PLAN CHECK FOR NEW SPROUTS. SERVICE SIZE 2000AMPS, PART OF EXISTING DISTRIBUTION SYSTEM.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67389	16041-20001-28567	8300 N TAMPA AVE #A	91324	12	192B117   733	2784019004	C2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			12/15/2017 12:00:00 AM			PC Approved	12/15/2017 12:00:00 AM	ADDRESS	34.2208	-118.55334	12.15.2017 - Approved plans lost - rechecking from scratch. Same scope of work.=====TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG.  TOTAL SQUARE FOOTAGE 1810 TENANT A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67390	18041-20000-01636	2759 N HOLLYVIEW CT	90068	4	153B181   590	5549031***	(T)(Q)RD3-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.11869	-118.34249	PV1.  Install 7.6 kW AC/ 10.15 kW DC roof mounted grid tied PV system.  (29) modules with power optimizers/string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67391	10041-10000-25655	1901 S OVERLAND AVE 1-9	90025	5	129B157   604	4321010048	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			12/28/2010 12:00:00 AM			PC Approved	12/28/2010 12:00:00 AM	ADDRESS	34.05001	-118.43196	TI in the parking & corridoor area of the 9 units appartment BLDG. EPC is for T24. (Permit was pulled)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67392	17041-20004-27543	11631 W VICTORY BLVD	91606	2	180B169  1019	2335012019	C1-1VL, RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.18685	-118.38564	"11/27/19CHANGES TO APPROVED SET DELTA  ""E"" ONLY. CHANGES TO RELOCATION OF GENERATOR AND SIZE OF CONDUCTOR."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67393	13041-20000-21985	5343 W IMPERIAL HWY BLDG A-PV-2	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	33.93128	-118.37337	PV-2. BLDGA. 333kW AC. Prologis. Bipolar System. Please plan check concurrently with BLDG B.333kVA isolation transformer will be on separate application.WILL FILE VARIANCE TO SHOW THAT NEW SERVICE IS ONLY FOR PV USE$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67394	12041-10000-22561	7315 W MELROSE AVE	90046	5	141B181   531	5526008028	C4-1XL, R1-1	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	12/26/2012 12:00:00 AM	ADDRESS	34.08368	-118.34926	CONVERT OPEN COMMERCIAL SPACE ON THE 2ND FL TO OPEN AND PRIVATE OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67395	17041-20000-30702	7048 N SEDAN AVE	91307	12	183B097   210	2026028033	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.1994	-118.62853	"""17.93$ permit fee due to senate bill 1222""Plan check for solar pv system, roof-mounted on SFD.12.8kW ungrounded system. (40) 320W AC modules.Derating main breaker."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67396	19041-10000-28599	9365 N SAN FERNANDO ROAD	91352	6	198B165   102	2631001021	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.23893	-118.39367	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67397	14041-10000-22385	6141 W FRANKLIN AVE	90068	4	150A189   174	5586007045	R3-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	PIN	34.10539772	-118.32367026	PLANCHECK FOR T24 ENERGY. INTERIOR REMODEL OF (E) 649 S.F. LOUNGE AT (E) HOTEL LOBBY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67398	18041-20000-48765	7515 N WOODLEY AVE	91406	6	186B141   234	2205022003	[Q]M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			12/26/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.20702	-118.48388	Plan check for a PV2 roof-mounted PV system. System size 12.6 kWdc/11.46 kWac-CEC and consists of (2) inverters, (42) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67399	19041-20000-12124	6756 W HOLLYWOOD BLVD	90028	13	148-5A185 151	5547012005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM			PC Approved	04/03/2019 12:00:00 AM	ADDRESS	34.10139	-118.33777	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 1165 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67400	18041-10000-01194	14545 W VICTORY BLVD	91411	6	180B149   844	2236023020	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Closed	07/27/2018 12:00:00 AM	ADDRESS	34.18686	-118.45026	PC FOR ROOF MOUNTED PV ON SLD. SCOPE INCULDES ADDITION OF MODULES TO EXSITING PV SYSTEM. SCOPE INCLUDES 16 NEW MODULES WITH MICROINVERTERS. ADDED NEW SIZE 3.84KWAC/4.6KWDCTOTAL NEW SYSTEM SIZE 9.14KWDC/7.89KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67401	19041-10000-04716	5901 W OLYMPIC BLVD 500	90036	4	132B177   666	5086024025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.05771	-118.35996	PLAN CHECK FOR MEDICAL OFFICE REMODEL OF AN EXISTING MEDICAL OFFICE TOTAL EFFECTED AREA 825 SQFT SCOPE OF WORK INCLUDES ADDING NEW LIGHTS AND EQUIPMENTS ON EXISTING PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67402	15041-20000-43520	9719 N KESSLER AVE	91311	12	201B113   604	2761016028	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.2467	-118.56791	Plan check for PV roof mounted system. System size: 5.0kWac with 20 modules and 1 inverter (5.0KWac) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67403	17041-10000-39835	2437 W PICO BLVD	90006	1	129B197  1057	5076019024	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Issued	11/03/2017 12:00:00 AM	ADDRESS	34.04743	-118.29011	Remove outdoor Metal Halide fixure and replac with new LED Fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67404	16041-10000-20256	8500 W BEVERLY BLVD 628	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	03/09/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	T-24, PC FOR ENERGY ONLY. T.I. OF AN EXISTING RETAIL SPACE (FOOT LOCKER). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 8809 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67405	11041-10000-05813	6151 W CENTURY BLVD Suite #100	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/24/2011 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	33.9457	-118.39308	TI IN AN EXISTING OFFICE AREA ON THE 1ST FLOOR IN SUITE #100.  PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67406	18041-20001-34268	10355 N CHRISTINE PL	91311	12	204B117    72	2708024019	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM			PC Approved	01/08/2019 12:00:00 AM	ADDRESS	34.25881	-118.56159	Expedite per applicant requestPlan check for PV roof mounted system, system size:15.2kW with 62 PV Modules, and 2 inverters(7.6kW) connected to 400A Panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67407	17041-20000-11615	5832 N MURIETTA AVE	91401	2	174B153   156	2246015005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.17669	-118.43871	pv1install roof mounted pv system sized 4.4kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67408	19041-10001-04594	611 W WILSHIRE BLVD	90017	14	129A209    82	5144005021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM			Reviewed by Supervisor	09/25/2019 12:00:00 AM	ADDRESS	34.04838	-118.25639	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF FAULT CURRENT VALUES TO THE UPS AND INSTALLATION OF CURRENT LIMITING FUSES. ORIGINAL PLAN CHECKER BEHROOZ HOORIANINOTE CHANGES ON CLOUDED AREAS. _____________________________________________________________________REPLACING TWO EXISTING DEFECTIVE 125KVA UPS WITH TWO NEW UPS's AT THE SAME LOCATION LIKE TO LIKE. NO NEW LOADS WERE ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67409	14041-10000-16028	307 N LA BREA AVE	90036	5	138B181   364	5525033032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			06/16/2014 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.07647	-118.34435	PC FOR POWER AND ENERGY. TI FOR A GAS STATION CONVENIENCE STORE. TOTAL AREA(406+1265+456) SQ FT INCLUDES CONDITIONED+ UNCONDITIONED+ OUTDOOR LIGHTING. NEWLY ADDED LOAD IS OVER 400 AMP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67410	17041-10000-33028	7830 N COWPER AVE	91304	12	189B089   275	2020028064	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.21298	-118.64772	PC FOR PV SYSTEM USING AC MODULES. TOTAL OF 40 MODULES. 13.8KW	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67411	14041-10001-23521	2645 S LA CIENEGA AVE	90034	10	123B173   670	5065007006	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.0335	-118.3785	Expedite per customer requestPV2 43.095 KW roof-mounted system including 169 hanwha solar modules and one Fronius CL 33.3KW  inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67412	16041-10000-26109	21051 W SHERMAN WAY	91303	3	186B105   870	2112019002	[Q]C2-1VL-CDO, [Q]P-1VL-CDO, [Q]R3-1-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.20125	-118.59216	TI TO PHARMACY. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67413	17041-10000-14445	10350 W SANTA MONICA BLVD GELSONS	90025	5	132B157   566	4319009056	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.05798	-118.42273	ALTERATIONS AT EXISTING GELSONS MARKET: NEW PANELS  SB and D1; new circuits for lighting, receptacles for gondolas, and receptacles for new monitos	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67414	11041-10000-12693	9505 S HAAS AVE	90047	8	093A191    67	6057014016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			06/20/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	10/05/2011 12:00:00 AM	ADDRESS	33.95	-118.31684	NEW 600A SERVICE UPGRADE AT A NEW CELL TOWER IN A CHURCH.  NEW PANELS AND SERVICE, INSTALL NEW LIGHT IN ELECTRICAL ROOM.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67415	10041-10000-18904	808 W 7TH ST	90017	14	129A209    60	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM			Corrections Issued	09/23/2010 12:00:00 AM	ADDRESS	34.04883	-118.25927	Ti in an existing Cafe. Plan check for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67416	10041-10000-06127	28090 S WESTERN AVE	90732	15	024B193     4	7442030206	P-1XL, [Q]C2-1XL, [Q]C4-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM			PC Approved	04/05/2010 12:00:00 AM	ADDRESS	33.76533	-118.31014	Replac (E) light fixtures with new,  add 100A new panel. Add putlets at CHASE BANK AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67417	16041-20000-20483	12741 W VENTURA BLVD	91604	2	165B161  1006	2375021017	C1.5-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Issued	07/12/2016 12:00:00 AM	ADDRESS	34.14491	-118.41084	Replace (E) 1000A service with (N) 1000A service to accommodate increased fault current from DWP.  Additional distribution equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67418	11041-10000-12108	10821 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Public Safety Only			06/13/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	34.26672	-118.52366	NEW FIRE WARNING SYSTEM WITH CENTRAL STATION MONITORING AT A SPROUTS FARMERS MARKET BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67419	19041-10000-46091	10428 N OSO AVE	91311	12	207B113   261	2707016019	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	34.26057	-118.57525	NEW ROOF MOUNTED 11.11KWdc (10.7KWac) PV1 SYSTEM WITH 34 @ (327W) PV AC PANELS ON A SINGLE FAMILY HOME.CONNECTED TO AN EXISTING 200 AMP SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67420	16041-20000-11387	8301 N CANOGA AVE	91304	3	192B105   594	2779036013	C2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			04/01/2016 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.22025	-118.59775	Plan check for power and energy. Project site is a new gas retail/market building and gas station. DWP service is existing (gas station is replacing car wash). Total lighting area = 24,086 sq. ft.Note: Building permit has been created under 16010-20000-00069	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67421	13041-20001-22680	1550 N WILCOX AVE	90028	13	148-5A187 338	5546013002	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			PC Approved	04/09/2014 12:00:00 AM	ADDRESS	34.09947	-118.33087	((changes to approved set of plans. changes include consolidation of circuits to common area panle.s this is hotel/motel. permit already issued for excess panels. no change in load))))EXISTING MIX USE. RENOVATION OF ENTIRE ELECTRICAL SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67422	17041-10000-33131	1201 S MATEO ST	90021	14	123A217   344	5166021019	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.02941	-118.2324	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 34400 SQ.FT (INDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67423	13041-10000-09264	15055 W ALTATA DR	90272	11	123B129   496	4411023012	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.03291	-118.5235	SINGLE FAMILY DWELLING, 2 STORIES PLUS BASEMENT. NEW ELECTRICAL SERVICE, NEW LIGHTING, AND NEW POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67424	16041-10000-33051	3667 S MCCLINTOCK AVE	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.02081	-118.29008	Plan check for title 24. Energy only Total area 734 sq.ftWomen locker in parking stracture ground floor.Scope of work includes new lights and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67425	19041-10001-41333	6919 N HAYVENHURST AVE	91406	6	183B137   341	2225002096	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM			Reviewed by Supervisor	12/13/2019 12:00:00 AM	ADDRESS	34.19629	-118.49258	PLAN CHECK FOR CHANGES TO APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA 1, CHANGES INCLUDE REVISIONS TO SINGLE LINE AND FLOOR PLAN. ORGINAL SCOPE OF WORK ((NEW CIRCUITS FOR  ELECTRIC VEHICLE CHARGERS. ))	Y	N	Regular Plan Check	06/10/2024 12:00:00 AM
67426	15041-10001-04084	4625 N LANKERSHIM BLVD	91602	2	168B173  1094	2421027009	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			Reviewed by Supervisor	12/28/2016 12:00:00 AM	ADDRESS	34.15471	-118.36871	RECHECKING LOST SET OF PLANS. ORIGINAL RTI WENT MISSING. THIS IS TO RECHECK AND RESTAMP AS A NEW RTI SET. PC BASED ON TIME ONLY. NO ADDITIONAL PERMIT ITEMS HAVE BEEN NOTED YET. this is plan check only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67427	13041-10000-04186	8500 W BEVERLY BLVD #789	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM			PC Approved	02/19/2013 12:00:00 AM	ADDRESS	34.07587	-118.37754	13041-10000-04186(N) TENANT IMPROVEMENT OF AN (E) 605 S.F. RETAIL SPACE; PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67428	15041-10000-04612	831 W VENICE BLVD	90015	1	126A203   148	5135030027	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.03976	-118.27491	PC FOR POWER AND ENERGY. TI FOR 5 UNITS, SINGLE STORY BUILDING. CHANGE OF USE FROM COLORING FABRICS TO WAREHOUSE. UPGRADING SERVICE AND ADD 5 SUBPANEL. TOTAL AREA 7050 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67429	16041-20000-30847	5601 N DE SOTO AVE MOB 2	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.17126	-118.58861	Plan check for power/emergency only. Kaiser Permanente medical building MOB 2 - replacing existing exit signs with new, reconnecting to existing normal/emergency circuits. (12) New exit signs, connecting to same circuits as nearby existing exit signs. Basement to 5th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67430	18041-20000-18405	14830 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.29504	-118.45413	Plan check for PV roof mounted system, System size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67431	18041-20000-28291	1636 N SAN ONOFRE DR	90272	11	132B133    38	4425001006	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2018 12:00:00 AM			Verifications in Progress	11/13/2018 12:00:00 AM	ADDRESS	34.06174	-118.50352	Plan check for power only. Project site is a new 2-story single family dwelling with a basement. Work includes a 600-amp service. Note: Building application has been generated under 18010-30000-00923	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67432	17041-10000-42315	2803 1/2 S VINEYARD AVE	90016	10	123B181  1294	5057010013	R2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Apartment			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.03103	-118.34483	PC for rooftop PV for new 3kW system in apartment. Installing six modules, one ABB central inveter and 200A load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67433	18041-20000-17440	1156 S CLARK DR	90035	5	132B169   806	4332014901	R3-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Issued	05/10/2018 12:00:00 AM	ADDRESS	34.05555	-118.38462	Plan check for the replacement FACP of an existing fire alarm system and the addition of (5) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67434	18041-20000-06691	7911 N WINNETKA AVE	91306	3	189B113   712	2107011060	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.21424	-118.57124	replace existing lighting fixtures with new led.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67435	14041-10000-05690	8812 W DAVID AVE	90034	10	126B169  1203	4301020020	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.03902	-118.38286	PV1. ROOFMOUNTED SOLAR SYSTEM WITH POWER OPTOMIZERS. TRANSFORMERLESS INVERTER. 1 STORY. SYSTEM SIZE: 2 KW DC. (8) CANADIAN SOLAR #CS6P-250(1) SOLAR EDGE SE3000A(8) SOLAR EDGE OP300	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67436	11041-10000-07663	8366 W BEVERLY BLVD	90048	5	138B173   481	5511011002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.07589	-118.37236	MAJOR TI IN AN EXISTING RETAIL STORE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67437	10041-20001-02885	17220 W VENTURA BLVD	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1VL, C2-1VL, C4-1VL	South Valley	Encino - Tarzana	Encino	YES	1396.00	Electrical	Electrical	Commercial			06/02/2010 12:00:00 AM			PC Approved	06/02/2010 12:00:00 AM	ADDRESS	34.16046	-118.50839	"Revision. Supplimental plan check for approved set. Change clouded on the plan as""delta 2"" showing some panel load revision and lighting set up."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67438	16041-20001-25890	2651 N HUTTON DR	90210	5	156B157   472	4385007005	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2016 12:00:00 AM			PC Approved	08/02/2016 12:00:00 AM	ADDRESS	34.11975	-118.43017	Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 11.7kW with 36 AC modules}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67439	14041-20000-18317	1727-1729 N LUCILE AVE	90026	13	145-5A203 139	5429016010	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM				Changes from previous aproved plan: 14041-20000-05777. changes only including service load calculation, additional  sub panel and branch circuits. Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67440	19041-20000-28109	19864 W FALCON CREST WAY	91326	12	217-5A115 120	2701025015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.28944	-118.5668	PV1.  Install 6.48 kW roof mounted grid tied PV system.  10 kWh energy storage system.  Protected load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67441	17041-10000-30312	3080 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	34.01607	-118.2138	TI TO EXISTING COMMERCIAL BUILDING. PC FOR POWER AND ENERGY. NEW 800A DISTRIBUTION WITH WAREHOUSE LOADS. TOTAL AFFECTED AREA IS 17650 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67442	15041-10000-26580	333 N BELMONT AVE 1-52	90026	13	136-5A207 212	5159003005	R4-1	Central	Westlake	Greater Echo Park Elysian		2083.02	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.06787	-118.26342	PC FOR A NEW FIRE ALARM SYSTEM FOR NEW (4) STORY MIX USED BLDG. (206) FA DEVICES, (6) CONTROL PANELS AND (1) ANNUNCIATOR (COMMUNICATION PANEL) , AND (1)  FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67443	17041-10000-30024	3345 W WILSHIRE BLVD	90010	10	132B197    22	5502028020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM	ADDRESS	34.06193	-118.2963	PC FOR FA SYSTEM USING MAIN PANEL AND 625 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67444	16041-20000-11725	930 S HILGARD AVE	90024	5	135B153   541	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.06306	-118.44116	Plan check for Title 24 only. Project site is the outdoor bar of an existing hotel. Project scope is a tenant improvement. Total outdoor lighting area = 2,500 sq. ft.Note: Building application has been created under 15016-40000-25368	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67445	13041-20000-35625	4937 N TOPEKA DR	91356	3	168B121    69	2176008003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.16032	-118.54767	PC FOR PV1 SINGLE FAMILY DWELLING. THIS IS PLAN CHECK FOR THE ROOF MOUNTED PART OF THE PV SYSTEM. ROOF MOUNTED 6KW AND SERVICE INTERCONNECTION.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67446	12041-10000-10293	10250 W SANTA MONICA BLVD #1240	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	07/11/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	xpress permit for retial store , title 24 is already approved.	N	N	Express Permit	06/10/2024 12:00:00 AM
67447	10041-10000-15415	719 N YALE ST 1-60	90012	1	133-5A213  25	5407024005	R4-1	Central	Central City North	Historic Cultural	YES	2071.02	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.06189	-118.24178	New 5 story, 60 units apartment building with 4 levels of garage below grade.; 14 DIFFERENT TYPES OF UNITSVARIANCE WAS SUBMITTED TO SEPARATE THE FA PLANS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67448	14041-10001-29382	2716 W OLYMPIC BLVD Ste 202	90006	10	129B197   223	5078010028	C2-2	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.05243	-118.29218	Change to approve set of plan add new lights. ((((Title 24 plan check only. TI to existing barber shop tenant space. 210 sq ft))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67449	10041-10000-03724	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian, Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	34.07196	-118.24719	tITLE 24 LIGHTING ALTERATION FOR STEDUIM CLUB AT DODGERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67450	12041-20000-17833	9527 N LANGDON AVE	91343	7	201B145   622	2656012003	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.00	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.24384	-118.46991	fire alarm foster home	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67451	16041-10000-24443	1500 N EL CENTRO AVE 2ND FLR	90028	13	148-5A189 331	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.09917	-118.32359	PLAN CHECK FOR POWER AND ENERGY.  T.I. TO SECOND FLOOR OFFICES.  TOTAL AREA = 17,087 SQ. FT.  LOAD GREATER THAN 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67452	18041-20000-10491	16815 W OAK VIEW DR	91436	5	168B133   346	2289018026	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.15532	-118.50014	Plan check for a PV1 roof-mounted PV system. System size is 10.9 kWac/11.9 kWdc and consits of (1) inverter and (36) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67453	15041-10000-27660	602 N FICKETT ST	90033	14	129A225    85	5177023024	[Q]C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			PC Info Complete	09/03/2015 12:00:00 AM	ADDRESS	34.04876	-118.2038	PV1 installation of a roof mounted solar system for a residential site connected to 3 meters.(1) inverter 3KW. (9) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67454	14041-10002-29506	1 W WORLD WAY WEST	90045	11	090B165    67	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Approved	05/07/2015 12:00:00 AM	PIN	33.94461393	-118.39808495	Change to an approved set by modifying the lighting plan and receptacle control. Note. all changes are applied to delta-3 only. (((Energy plan check for a CBP office T.I. . Total area covers 5735 SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67455	13041-10000-20105	6556 N PEACH AVE	91406	6	180B145   379	2234017026	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2013 12:00:00 AM	07/29/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.19032	-118.46741	installation of enphase micro inverters as part of  PV system on the roof of SFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67456	18041-10002-15820			12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM				PLAN CHECK FOR POWER AND ENERGY FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF LOADS WITH ADDITION OF NEW CONNECTED LOAD. UPDATE OF LOAD SUMMARY, ALTERATION TO LIGHTING SYSTEM, WITH UPDATED FIXTURE SCHEDULE HAS BEEN INCLUDED(CHANGING LIGHT FIXTURE TYPES) WITH CHANGES TO TITLE 24 DOCUMENTATION. ALL CHANGES HAVE BEEN CLOUDED UNDER DELTA 9	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67457	14041-20000-20036	2120 S BEVERLY DR	90034	5	126B165   234	4309017001	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.04367	-118.39487	PV1. Install 6.48 kW roof-mounted, utility-interactive PV system.    Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67458	15041-20000-13342	14602 W PLUMMER ST	91402	6	198B149    74	2650026023	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Expired	05/30/2017 12:00:00 AM	ADDRESS	34.24253	-118.45061	PC FOR SERVICE 600A ONLY. REPLACE FIRE DAMAGED SERVICE TO NEW 600A. EXISTING PANELS AND TENANTS TO REMAIN. EXISTING BRACINGS OKAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67459	12041-20000-18667	3715 S MCCLINTOCK AVE	90089	8	117B197     6	5039002034	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.02041	-118.29027	Plan check for power and energy. USC basement laboratory remodel. 5236 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67460	13041-10000-19688	2049 S CENTURY PARK EAST 2100-2200	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 PLAN CHECK ONLY. EMERGENCY LIGHTING. 6267 SQFT. HIGH RISE. TENANT IMPROVEMENT FOR 22ND FLOOR OF A HIGHRISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67461	18041-20000-32277	12910 W CULVER BLVD	90066	11	105B157   578	4221031006	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	33.98314	-118.42695	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,347 sq. ft.Permit fee is paid under 18041-90000-28310 Note: Building application has been generated under 16010-30000-05001	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67462	16041-30001-20849	2029 S SAWTELLE BLVD	90025	11	126B153   804	4261033014	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.04015	-118.44316	12/13/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 4. Changes have been made to the lighting floor plan and have been reflected onto the Title 24 Compliance forms. Outdoor lighting has also been added to the scope of work.*****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant. Total lighting area = 13,403 sq. ft.Note: Building application has been generated under 16014-30000-00898	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67463	14041-10000-22825	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	NEW FIRE ALARM INSTALLATION. 1116 FIRE ALARM DEVICES AND 1 CONTROL  PANEL.  Located at the (E) TBIT core of LAX. Limited to upgrades of the new TBIT renovation area and is to include: New digital audio amplifier (EST3) to be tied into the fire alarm system network to support the new initiating and audio devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67464	13041-20000-13403	10445 N LAUREL CANYON BLVD	91331	7	204B153    94	2618020011	[Q]C2-1VL-O-CDO, [Q]P-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.25948	-118.4332	T.I. for a Dental Office.  Upgrade existing panel.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67465	19041-20001-19959	9234 N ENCINO AVE	91325	12	198B129   276	2766011004	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Issued	06/07/2019 12:00:00 AM	ADDRESS	34.23885	-118.51548	"Changes to system - (2) modules added.  Plan check for entire system.  Work description now reads:""PV1.  Install 5.27 kW roof mounted grid tied PV system.  (17) modules with 5 kW rated inverter."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67466	14041-20000-24335	1674-1680 E 23RD ST	90011	9	117A213   132	5118021006	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM			Reviewed by Supervisor	10/17/2014 12:00:00 AM	ADDRESS	34.01575	-118.244	Tenant improvement and change of use from storage/warehouse to retail/warehouse with accessory office use.  Plan check for power and energy. per building submittal, plan check in accordance to 2008 building efficiency standards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67467	16041-20000-02385	416 W COTTAGE HOME ST	90012	1	136-5A215 111	5414017009	R3-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.06768	-118.23594	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel. Standard plan in use.(14) LG 300NK Modules(1) ABB PVI 3.8 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67468	18041-20002-47177	4536 E BEND DR	90065	1	153A221   386	5475018026	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2019 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.11216	-118.22032	02-12-2019 Changes to an approved set of plan, changes include relocate main service panel and PV load Center. All changes has been clouded. $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67469	16041-20000-21416	2000 S AVENUE OF THE STARS	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.05868	-118.41546	PLAN CHECK FOR ENERGY ONLY TO AN EXISTING 2 STORY GARAGE.  REMOVE AND REPLACE EXISTING FLUORESCENT LIGHTING TO LED LIGHTING.  NO NEW CIRCUITS USING EXISTING WIRING.  TOTAL SQUARE FOOTAGE 43982.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67470	14041-10001-14548	12404 W VENICE BLVD	90066	11	111B153   231	4235013044	[T][Q]C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM			PC Approved	09/05/2014 12:00:00 AM	ADDRESS	34.00336	-118.43363	(((9/5/2014 - Supp. app. for changes to an approved set.  Addition of two lighting fixtures and change of locations to receptacles. Permit for this application to be pulled on the master)))Original work description:  Title 24 only.  Total area = 1875 sq. ft.T.I. for existing building.  New starbucks with new fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67471	17041-20000-10591	8255 N WOODMAN AVE	91402	6	192B153   835	2213016021	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.22092	-118.43287	ti to an existing commercial space.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 2000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67472	13041-10001-10152	5185 W SUNSET BLVD	90027	13	147A195    71	5544015070	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Info Complete	05/17/2013 12:00:00 AM	ADDRESS	34.09828	-118.30305	Title 24 plan check for internet express permit pulled under 13041-90000-10152.  Restaurant remodel.Original Work Description: Rewiring or adding devices to existing electrical circuits for receptacles. Special equipment inspection for less than 600 volts	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67473	13041-10001-24755	2508 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.0334	-118.2974	EXPEDITED PER APPLICANTS REQUEST.PV1. INSTALL 2.94 KW DC ROOF MOUNTED SOLAR ARRAY OF 12 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67474	16041-20001-25288	15150 W ROXFORD ST	91342	7	228B145   441	2502004038	C1-1VL-CPIO	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM			PC Approved	10/14/2016 12:00:00 AM	ADDRESS	34.31841	-118.46333	EXPEDITE PER APPLICANTPV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20KW INTERCONNECTD WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67475	18041-10002-08932	9764 N NATICK AVE	91343	7	201B149   385	2650016004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2018 12:00:00 AM			PC Approved	07/10/2018 12:00:00 AM	ADDRESS	34.24767	-118.45286	PC FOR DC COUPLED ESS SYSTEM. SCOPE INCLUDES NEW LG DC ESS WITH AUTO TRANSFORMER ON PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67476	13041-10000-34482	6220 N TOPANGA CANYON BLVD BLD #E	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	07/18/2014 12:00:00 AM		Permit Closed	01/13/2017 12:00:00 AM	ADDRESS	34.1841	-118.60553	PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING E.BUILDING PERMIT # 13010-10000-02908.New 2 STORY retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67477	19041-10000-45328	9103 N SEPULVEDA BLVD	91343	7	198B145   385	2656026012	C2-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	01/21/2020 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.23587	-118.46796	T-24 PLAN CHECK FOR A NEW TI IN AN EXISITING SPACE. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1500 SQ. FT.COMPLY WITH DEPARTMENT ORDER effective date11/05/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67478	14041-10000-30810	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	Service upgrade in an exsisting shopping center. Core & Shell only and title 24 outdoor area = 62,269 sq. ft. ALL future TI's require complete Electrical Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67479	15041-20000-39125	18133 W VENTURA BLVD #1	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	T.I. at (E)portion of medical office on 1st floor. PC for Power and Energy per art. 517.   Total area: 9,778 sq.ft . suite # 1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67480	13041-10000-18862	625 S GRAND AVE	90017	14	129A209    82	5144005021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			Reviewed by Supervisor	08/09/2013 12:00:00 AM	ADDRESS	34.04822	-118.25599	RECONNECT EXISTING EQUIPMENT FROM BUS U5 TO U1. 30 STORIES ( HIGH RISE ). WORK BEING PERFORMED ALL 30 FLOORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67481	11041-10006-10748	1900 S SEPULVEDA BLVD	90025	5	126B153   181	4323022031	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.04447	-118.4413	REVISIONS TO PERMITTED SET OF PLANS-NEW PANELBOARD AND CIRCUITS FOR THE INSTALLATION OF A LISTED OXYGEN GENERATOR  PERMANENTLY INSTALLED FOR USE AS SOURCE OF OXYGEN DURING SURGERY AT THE PET HOSPITAL . GENERATOR WILL BE LOCATED IN GARAGE AT LEVEL B1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67482	16041-20002-12644	8715 N TOBIAS AVE	91402	6	195B149   570	2653003123	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Apartment			09/20/2018 12:00:00 AM			PC Approved	09/20/2018 12:00:00 AM	ADDRESS	34.2286	-118.45189	09-20-2018 Changes to an approved set of plan. Changes include update HP panel schedule and load calculation. All changes has been clouded as delta 3. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67483	18041-10001-07223	7353 W MELROSE AVE B1	90046	5	141B181   522	5526009031	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.08373	-118.35013	This is plan check and additional permit to (E) permit# 18041-10000-07223: Plan check for TI on (E) commercial space unit B1, change of use to Coffee shop. Total area: 549 sq. ft(B# 17016-10000-24767))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67484	16041-20001-44201	6357 N COLBATH AVE	91401	2	180B153  1120	2239003001	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM			PC Approved	05/12/2017 12:00:00 AM	ADDRESS	34.18638	-118.43683	Title 24 plan check for garage lighting per inspector correction notice.  ((((N) 6-GANG (5 METER & 1 HOUSE METER) 400AMP SERVICE. INSTALL (50) 20AMP CIRCUITS, (5) 30AMP CIRCUITS AND (5) SUB-PANELSJ)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67485	12041-20000-01458	15821 W VENTURA BLVD	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.15584	-118.47812	energy plan check #320	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67486	16041-10000-07831	15365 W MAGNOLIA BLVD	91403	4	172-5A145  94	2250002023	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.16501	-118.46841	T-24, REPLACING AND ADDING NEW OUTDOOR LIGHTING TO A SCHOOL. TOTAL SQ. FT. 11427.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67487	12041-20000-07318	12950 W CULVER BLVD 2nd fl.	90066	11	105B157   607	4221031007	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM			PC Approved	03/30/2012 12:00:00 AM	ADDRESS	33.98222	-118.4277	Office t.i.Energyexist. permit 09041-200000-06255	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67488	19041-10000-19579	9848 N DE SOTO AVE	91311	12	201B109   121	2748004054	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			Reviewed by Supervisor	06/17/2019 12:00:00 AM	ADDRESS	34.24917	-118.58836	PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 774 MODULES (Q-PEAK 390), 388 OPTIMIZERS (P850 ), 2 INVERTERS ( SE 99.9K), AND 1 INVERTERS ( SE 33.3K). SYSTEM SIZE IS 233.1KWac AND 301.86KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67489	15041-10000-15359	3630 W WATT WAY	90089	9	118-5A201  14	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.02062	-118.28738	REMOVAL OF EXISTING NORMAL LOAD ON EDBLNB BOARD AND RECONNECT T-EDBLNB BOARD TO EMERGENCY GENERATOR.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67490	16041-10001-31802	3221 N ANDRITA ST	90065	13	154-5A213  99	5458016023	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Expired	09/02/2023 12:00:00 AM	ADDRESS	34.11823	-118.24369	Changes to approved set.  Changes to module type to LG315N1C-Z4.  Changes to number of modules to 9.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67491	11041-10000-16279	2130 E 1ST ST	90033	14	127-5A223 122	5183008901	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	09/29/2011 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	34.04433	-118.21291	TENANT IMPROVEMENT; CORE AND SHELL ON SEPARATE APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67492	14041-10000-19682	3816 N HARRIMAN AVE	90032	14	145-5A233 286	5306010038	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.09115	-118.18098	SOLAR PV STANDARD PLAN. CENTRAL/STRING INVERTER SYSTEMS FOR 1 AND 2 FAMILY DWELLINGS. # OF INVERTERS INSTALLED: 2. INVERTER OUTPUT POWER RATING: 4000 WATTS EACH. 16 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67493	15041-20000-09448	6612 N ENSIGN AVE	91606	2	180B173   447	2319019014	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Expired	04/25/2017 12:00:00 AM	ADDRESS	34.19073	-118.37163	PV1 SFD. TOTAL SYSTEM SIZE 4.3KW AC UISNG MICROINVERTER SYSTEM. USES ENPHASE M215. 20 MODULES IN TOTAL. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67494	11041-20000-19053	9590 W HIDDEN VALLEY ROAD	90210	5	156B165   229	4387007001	RE20-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2011 12:00:00 AM	07/02/2012 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.12115	-118.40524	PLAN CHECK FOR NEW 2-STORY SINGLE FAMILY DWELLING WITH ATTACHED 4-CAR GARAGE WITH 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67495	18041-10000-37356	1030 N SWARTHMORE AVE 4-105	90272	11	129B125   591	4423016007	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM			PC Approved	10/01/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	10/01/2018Plan check only, note changes on Delta 4. Scope of work includes the addition of bollards and panel locations. __________________________________________DELTA 3 CHANGES TO APPROVED PLANS FOR ADDING AN ACCESSIBLE DISCONNECT ON THE PRIMARY SIDE OF THE TRANSFORMER AND NEW CONDENSING UNITS.<<<PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT(RESTAURANT) - SCOPE INCLUDES CONNECTING TO EXISTING DISTRIBUTION EQUPMENT RATED AT 800A 480/277V DISTRIBUTION BOARD WITH APPROX. 400A OF NEW CONNECTED LOAD. TOTAL AFFECTED AREA 2384 SQ. FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67496	16041-10001-31255	3254 N LOWRY ROAD	90027	4	153A203   338	5434004019	R1-1	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.11199	-118.27936	Rechecking wiring to ac combiner panel. no nuetral needed. removed from plans. revised conduit size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67497	14041-10000-01061	1458 S SAN PEDRO ST #103	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/14/2014 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	Remove HID light fixtures and replace with new fluorescent fixtures in a retail space.   Plan check only for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67498	18041-20000-15410	7636 W MEMORY DR	91042	7	210B197   195	2552031013	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.27069	-118.29803	pv1install roof mounted pv system sized 5kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67499	10041-10000-08916	7320 N WOODLAKE AVE #330	91307	3	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	06/29/2010 12:00:00 AM		Permit Finaled	09/21/2010 12:00:00 AM	ADDRESS	34.20263	-118.63189	Ti in a doctor office. Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67500	18041-10000-42412	990 N VINE ST	90038	13	144B189   883	5534026026	C2-1D	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Issued	11/06/2018 12:00:00 AM	ADDRESS	34.08869	-118.32643	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67501	15041-20000-43726	8516 N O'MELVENY AVE	91352	6	192B169   295	2633033003	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.22459	-118.39141	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.9KWdc/3.0KWac.(12)MODULES-SUNEDISON 325W (12)OPTIMIZERS-SOLAR EDGE P400(1)INVERTER-SOLAR EDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67502	13041-10000-21095	9717 W JOHANNA PL	91040	7	204B181   222	2549026015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	09/24/2013 12:00:00 AM	ADDRESS	34.25657	-118.34344	PV1.   Install 7.84 kW roof-mounted solar array, interconnect with main service panel.  {Transformerless inverter: Aurora PVI-6000-OUTD-US-Z} {32 modules: Trina Solar TSM-245PC05/PA05.18}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67503	18041-20000-35431	12710 W ADMIRAL AVE	90066	11	105B157   140	4223021020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	33.98721	-118.42623	PV1.  Install 7.250 kW DC roof mounted grid tied PV system with energy storage system.  (25) modules with 7.6 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67504	13041-10000-33604	1225 S VERMONT AVE	90006	1	129B197   940	5078028006	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			12/03/2013 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.04827	-118.29188	Plan check for power and energy.  New 4 story 40 units apartment building, over on subterranean parking garage. area 3126 sq ft.Note: Variance to separate fire alarm submitted, and permit to change address to 1225 S. Vermont.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67505	16041-20000-27905	12300 W WILSHIRE BLVD 3rd Floor	90025	11	126B145   406	4267036038	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.04245	-118.46922	Plan check for energy only. TI to existing commercial office in high rise building. New lighting (incl. emergency) and receptacles. 1,547sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67506	18041-10000-31577	12921 W MAGNOLIA BLVD	91423	4	171B161   451	2345017031	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.16503	-118.41465	Plan check for T24only, TI on (E) Ralph. Add (5) recessed lighting and (3) runs of track lights in the produce area. Scope does not include emergency lights and exit signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67507	18041-20000-08945	539 S MAPLETON DR	90024	5	138B157    57	4359013038	RE40-1	West Los Angeles	Westwood	Bel Air - Beverly Crest, Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.07466	-118.42924	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222pv1install roof mounted pv system sized 19kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67508	13041-10000-24668	19223 W PRAIRIE ST	91324	12	198B117   141	2762022013	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.23922	-118.55244	PV1 ROOF MOUNTED SOLAR INSTALLATION.  SYSTEM SIZE IS 8.085 KW DC AND 6.6 KW AC. [INVERTER: POWER-ONE # AURORA PVI-3.6-OUTD-S-US AND POWER-ONE # AURORA PVI-3.0-OUTD-S-US |||| MODULES: TRINA SOLAR # TSM-245PC05/PA05.18]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67509	11041-20000-09474	4802 N EAGLE ROCK BLVD	90041	14	160-5A221 356	5685009037	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1816.00	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.13259	-118.21579	PLAN CHECK FOR T24 ENERGY FOR RESTROOMS & LOCKER AND OUTDOOR LIGHT. PERMIT FOR NEW PANEL AND BRANCH CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67510	14041-10002-08514	6801 W HOLLYWOOD BLVD #170	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	changes to approved set of plans.Changes under delta 7. Plan check only. Changes include revising T24 counts for uplight for floor, wiring for emergency lights to general lighting, and wiring.  changes include change in lighting fixture and removal of fixtures in sales area. corrected sales area in calc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67511	15041-10000-04534	380 WORLD WAY T 35	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM			PC Approved	03/17/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Title 24 plan check only.  Total area = 162 sq. ft.T.I. to currency exchange counter space at airport.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67512	13041-20000-35065	6401 W HOLLYWOOD BLVD	90028	13	148-5A187 139	5546006003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.10177	-118.32972	T24 FOR OUTDOOR LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67513	19041-20000-29388	5939 N CANOGA AVE	91367	3	177B105    87	2146006052	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.17815	-118.59772	Plan check for new fire alarm system in existing building, Total new fire alarm device: 84 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67514	17041-10000-39097	205 N LAKE SHORE TER	90026	13	135A207   195	5159017009	R3-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	34.06457	-118.26115	PC for 2.9 kW roofmounted solar PV.  Installing 11 modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67515	13041-20001-18139	1470 W 184TH ST	90248	15	060B193    72	6108015003	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	33.86368	-118.30204	((CHANGES MADE TO MODULE ORIENTATION ONLY))PV1.  Install 5.886 kW garage roof-mounted solar array, interconnect into house main service panel (100A service).  {18 modules: SunPower SPR-327NE-WHT-D} {Transformerless inverter: PowerOne PVI-6000-OUTD-US }	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67516	19041-10003-30030	137 W 60TH ST	90003	9	105B201   473	6005015019	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM			Corrections Issued	12/17/2019 12:00:00 AM	ADDRESS	33.98524	-118.27528	CHANGES ON APPROVED SET ON PV PLANS. ADDRESS DELTA 3 CHANGES. ADDING A NEW SUBPANEL RATED FOR 1OOA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67517	12041-20000-07404	6430 W SUNSET BLVD SUITE 1550	90028	13	147A187   153	5546014047		Central				1908.02	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM			PC Approved	03/30/2012 12:00:00 AM	ADDRESS	34.09782	-118.32979	T.I. - Office space. Plan-check for lighting compliance and egress/exit lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67518	11041-20000-18963	1921 N BEL-AIR ROAD	90077	5	150A151   686	4370013045	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2011 12:00:00 AM	10/21/2011 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	ADDRESS	34.10445	-118.45031	PLAN CHECK FOR NEW 600A SERVICE, NEW PANELS, AND CKTS FOR EXISTING 3 STORY SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67519	15041-10000-10279	900 N ALAMEDA ST 1st Floor	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.05855	-118.23671	AS PART OF PARALLELING GEN SETS, INSTALLATION OF NEW 400A 4.16 kV SECTION THAT SUPPLIES  4.16 kV 2000 kVA XFMR AND CONDUCTORS TO PARALLELING 5000A 480/277Y SWBD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67520	10041-20000-19747	9430 N TOPANGA CANYON BLVD #209	91311	12	198B101   137	2746013014	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM	10/05/2010 12:00:00 AM		Permit Finaled	11/05/2010 12:00:00 AM	ADDRESS	34.24159	-118.60598	Plan check T24 Energy general/emergency lighting for office TI. Relocation of existing lighting fixtures. Exit signs are existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67521	14041-10000-13404	629 E 9TH ST	90014	14	126A211   411	5145009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	PIN	34.03765548	-118.2504372	T24, Remove HID light fixtures and replace with new fluorescent fixtures. Total area 1988 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67522	16041-10000-45535	730 S ALAMEDA ST	90021	14	123A215   224	5166032037	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.03268	-118.23767	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures for interior. Total affected area is 8700 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67523	14041-10000-34388	333 S GRAND AVE 40th flr	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.05271	-118.25179	Title 24 plan check only.  Total area = 780 sq. ft.Lighting renovation to restroom and storage areas on 40th floor of existing commercial highrise space.permit under 14041-10000-35646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67524	10041-10000-13051	11923 W SANTA MONICA BLVD	90025	11	126B145   463	4263031032	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	07/30/2010 12:00:00 AM	ADDRESS	34.04176	-118.461	TENANT IMPROVEMENT AT THEEL SUPER TACO RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67525	18041-10001-00829	5955 N DE SOTO AVE #250	91367	3	177B105    78	2149002027	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/25/2018 12:00:00 AM		Issued	01/25/2018 12:00:00 AM	ADDRESS	34.17888	-118.59071	Supplemental for plan checking T24 only. Scope of this project includes install of new lighting. Partial fees for recepetacles are under permit 18041-30000-00829. Total area is 8478sqft. B# 17016-20000-36987	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67526	15041-20001-17265	2275 N CHELAN DR	90046	4	153B181   305	5572011030	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM			Reviewed by Supervisor	06/09/2015 12:00:00 AM	PIN	34.11307861	-118.34795154	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (42) modules, and (42) dc/dc converters. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67527	16041-30000-39996	6600 N TOPANGA CANYON BLVD #2034	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check Title 24 only in existing space for ALDO Space # 2034 T.I. Total area: 2,208 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67528	16041-10000-42299	616 S MASSELIN AVE	90036	4	135B181   650	5508014028	R4-1	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			12/01/2016 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.06432	-118.35237	PC for new fire alarm system with 355 devices and 25 panels for existing four story apartment building with subtarranean parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67529	18041-10002-21268	12566 W ROSE AVE	90066	11	117B153  1130	4247023014	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.01336	-118.44443	**6/13/18 designer removed this battery system from single line ( ESS no longer on the scope) ~~ DMBATTERY INSTALLATION, FEES____________________________EXPEDITED FEESPV1, ROOF MOUNTED SOLAR SYSTEM USING MICRO INVERTERS. TOTAL (10) MODULES AND (10) IQ6 MICROINVERTERS. TOTAL SYSTEM SIZE IS 2.4KWAC AND 3KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67530	17041-20000-43085	8436 N GREENBUSH AVE	91402	6	192B157   427	2627034012	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2017 12:00:00 AM	11/30/2017 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.22378	-118.4227	PV1.  Install 5.2 kW roof mounted grid tied PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67531	11041-20000-04011	1423 N TANAGER WAY	90069	5	147B169   762	5560004007	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2011 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	ADDRESS	34.0972	-118.38559	single family with green code compliance	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67532	18041-10000-10616	4649 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.04716	-118.3389	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67533	12041-10000-09784	6116 W ELEANOR AVE	90038	13	144B189   780	5534024005	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			04/30/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Expired	07/07/2014 12:00:00 AM	ADDRESS	34.08971	-118.32506	INSTALLING ON THE ROOF OF AN APARTMENT BUILDING  A 34.8KW DC PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67534	14041-10001-07652	550 S MAPLETON DR	90024	5	138B157    56	4359013028	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	04/21/2014 12:00:00 AM	ADDRESS	34.07442	-118.42882	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 11.112 KW DC ROOF-MOUNETED SOLAR ARRAY ON A TWO STORY HOMAE,  INTERCONNECT WITH MAIN SERVICE PANEL.APPLICANT SHOULD BRING THE FIRE DEPARTMENT APPROVED SET,. (1) TRANSFORMERLESS INVERTER : POWER-ONE AURORA PVI-3.0-OUTD-US(208) &(2) POWER-ONE AURORA PVI-3.6-OUTD-US(208)(34) MODULES; SUNPOWER E20/327 NE-WHT-D}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67535	18041-20001-09554	22433 W NORTH SUMMIT RIDGE CIR	91311	12	198B101    60	2727022007	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2018 12:00:00 AM			PC Approved	04/02/2018 12:00:00 AM	ADDRESS	34.24218	-118.61597	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 20.79 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67536	14041-20001-20004	16409 W GLEDHILL ST	91343	12	198B137   141	2676010019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.24214	-118.48964	SUPPLEMENTAL TO AN APPROVED SET OF PLANS.  ADDITION OF 2 TRINA SOLR TSM-255 MODULES.New roof mounted PV system with total system size 3.6KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67537	13041-10000-25865	18631 W LASSEN ST PV 1	91324	12	201B121   104	2729020009	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.25029	-118.53943	PLAN-CHECK ONLY APPLICATION; INSTALL ROOF MOUNTED SOLAR, INTERCONNECT WITH MAIN SERVICE PANEL, SYSTEM SIZE 9 KW DC. (36) MODULES-TRINA #TSM-250PA05.18, (1)INVERTER -FRONIUS #IG  PLUS V 7.5. SUPPLEMENTAL TO PERMIT #13041-20000-22355 TO ADD 10 MODULES, COMBINER BOX. THE ADDITION OF 10 MODULES & COMBINER BOX WILL BE SUPPLEMENTAL TO 13041-20000-22355	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67538	16041-20000-02411	7709 W FOOTHILL BLVD	91042	7	204B197   640	2558008015	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			Reviewed by Supervisor	02/03/2016 12:00:00 AM	ADDRESS	34.25695	-118.3002	PV2. System is being installed on a commercial building (medical). Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (27) SolarWorld SW285 Modules(27) Solaredge P-400 Power Optimizers(1) Solaredge SE 6000 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67539	15041-20000-04947	13700 W FOOTHILL BLVD	91342	7	222B153    63	2509014902	RA-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Closed	07/06/2017 12:00:00 AM	ADDRESS	34.30848	-118.43206	Plan check for power and energy. Project site is an existing commercial space. Project scope is a tenant improvement which includes a new 800-amp service, (1) 800 amp-rated switchboard, (5) 200 amp-rated panels, and associated loads. Indoor lighting area = 1,540 sq. ft. and outdoor lighting area = 18,000 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67540	17041-20001-19649	18740 W KIRKCOLM LANE	91326	12	216B121    86	2870007007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.29229	-118.54173	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with AC coupled battery backup system for SFD.10.4kW ungrounded system. (31) 325W pv modules. (1) 5kW Tesla Powerwall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67541	14041-10003-21294	915 N LA BREA AVE 1-179	90046	5	144B181   745	5531016023	[T][Q]RAS4-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			01/11/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.08758	-118.34425	01/11/16Changes to an approved set. All changes made under delta 5. Changes include replacing the 248 MIZ-24S-W wall mounted mini horns with 269 GHLFW wall mounted low frequency horns. Note: original application paid under PCIS#14041-10000-21294((((Installation of a complete, non high rise, code minimum, addressable fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67542	19041-10000-01064	811 W OLYMPIC BLVD	90015	14	127-5A207   6	5138003014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.04524	-118.26427	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67543	14041-20000-18432	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			07/09/2014 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	03/16/2015 12:00:00 AM	ADDRESS	34.30155	-118.46112	dry room installation and support equipment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67544	13041-10007-13119	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	"Changes to an approved set of plans. All changes are clouded under delta 27. All changes to reflect what is on the field. Changes include removing loads for ""DP5"" for future use."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67545	13041-20000-30012	658 S MANSFIELD AVE	90036	4	135B181   837	5507020044	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.06328	-118.34062	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. 15 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67546	12041-10003-27734	2500 S NAVY WAY Rail OPS-Bldg	90731	15	021B209   245	7440022909		Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Public Safety Only			11/16/2012 12:00:00 AM	01/15/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	33.73363	-118.2408	Modify existing fire alarm system for Pola Maersk (port of LA) 4of 6 Rail Operation Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67547	19041-20000-24159	24359 W STONE BEND LANE	91304	12	192B089   175	2017038007	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.22043	-118.65605	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.88KW DC/5.2KW AC. SCOPE OF WORK INCLUDES (9) SC-B2 PV MODULES AND A DELTA SOLIVIA 5.2 TL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67548	14041-20001-14572	4458 N WESTCHESTER DR	91364	3	166-5A111  38	2174013027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.15172	-118.5836	Fee for expedite only.*****Roof mounted PV system.  Total system size 17KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67549	18041-10000-29976	6200 N VARIEL AVE	91367	3	177B105   132	2149004024	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	34.18341	-118.59258	PLAN CHECK FOR FIRE ALARM SYSTEM FOR 7 STORY APPARTMENT WITH 2 LEVELS OF UNDERGROUND PARKING - SYSTEM SIZE 1 FACP AND 703 DEVICES WITH 8 RPS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67550	11041-20004-15575	11665-11675 W VICTORY BLVD	91606	2	180B169  1107	2335010020	(T)(Q)RAS4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.01	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.18685	-118.3867	Changes to approved set of plans from 11041-20000-15575. Addition of loads to Panel CW. Plan check for POWER ONLY. ====> Submittal 2 has been outdoor Title 2411041-20002-15575: CHANGE OF ADDRESS FROM 11671 VICTORY BL  (PER WATER AND POWER)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67551	18041-20000-26889	220 N BRISTOL AVE	90049	11	132B137   230	4405019020	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	10/29/2020 12:00:00 AM	ADDRESS	34.05934	-118.48845	Plan check for a PV1 roof-mounted PV system. System size is 27 kWdc and consists of (75) AC PV modules, each rated at 320 Wac, and (2) load centers.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67552	10041-10000-15967	445 E ANAHEIM ST STE  F-L	90744	15	030B209   158	7423016017	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM	10/20/2010 12:00:00 AM		Permit Finaled	01/10/2011 12:00:00 AM	ADDRESS	33.78039	-118.25802	TENANT IMPROVEMENT: CONVERT PORTION 36' X 40' (1140 SQ FT) Of  RETAIL SPACE TO MEDICAL OFFICE AND COMBINE IT WITH (E) MEDICAL OFFICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67553	14041-10000-09244	6101 W CENTURY BLVD	90045	11	090B169     4	4124030036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM			PC Approved	04/08/2014 12:00:00 AM	ADDRESS	33.9457	-118.39149	TENANT IMPROVEMENT IN EXISTING RESTAURANTPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67554	15041-20000-33434	16541 W GREENLEAF ST	91436	5	168B137   459	2284005008	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.15604	-118.49369	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67555	13041-20000-10443	658 S SYCAMORE AVE PV-1	90036	4	135B181   841	5507022019	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	06/12/2013 12:00:00 AM	ADDRESS	34.06327	-118.34279	PV-1. Plan check for microinverter standard plan. 2.15kW inverter total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67556	17041-20000-46494	10625 W TABOR ST	90034	5	120B161   930	4314011014	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			12/28/2017 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	34.02357	-118.41014	Plan check for solar pv system w/roof-mounted array on apartment building.9kW ungrounded system. (31) 360W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67557	16041-10000-14907	10960 W WILSHIRE BLVD SUITE 1525	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	04/28/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS FOR AN OFFICE SPACE FOR SUITE 1525. TOTAL AFFECTED AREA IS 930 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67558	14041-20001-33064	16509 W SHAMHART DR	91344	12	216B137   335	2609030026	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2014 12:00:00 AM			PC Approved	12/26/2014 12:00:00 AM	ADDRESS	34.28723	-118.49139	expedite per customer request.pv1install roof mounted pv system sized 6.0kw interconnected with msp.(27) canadian solar cs6p-250p modules(1) solaredge se6000 tr inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67559	19041-10001-25125	3411 S SAN PEDRO ST	90011	9	117A207   155	5120022013	M1-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.01497	-118.26569	TI IN AN EXISTING COMMERCIAL AREA. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER 19041-20000-25125TOTAL AREA: 1785 SQR FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67560	19041-10000-45609	4907 N ARCOLA AVE	91601	4	168B177   247	2420011010	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Issued	11/06/2019 12:00:00 AM	ADDRESS	34.15974	-118.35513	INSTALLATION OF ONE NEW TESLA POWERWALL2 BATTERY TO AN EXISTING 10KWAC PV1 SYSTEM.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67561	11041-10001-25547	7755 N ORION AVE	91406	6	189B145   561	2222004003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2012 12:00:00 AM			PC Approved	06/15/2012 12:00:00 AM	ADDRESS	34.21181	-118.4707	New rooftop photovoltaic system for a single family residence and new 200A house panel upgrade.  System uses Enphase M215 microinverters.  Variance will be file to allow use enphase.  10  pv modules.(((((((    one portion of the roof approved under 10000 and other portion per inspectors request is send back to plan check although the system is existing.)))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67562	17041-10001-28445	1301 S FIGUEROA ST	90015	9	126A205     9	5134007933	(Q)CEC-4D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.04058	-118.26853	Supplemental PC for PV expedite fees	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67563	12041-10000-01455	650 S HILL ST #910	90014	14	129A211   215	5144003042	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	01/20/2012 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.04623	-118.25392	T24 ENERGY PLAN CHECK FOR SUITE #910 TI. PERMIT TO RELOCATE EXISTING LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67564	19041-10000-25901	410 W 7TH ST	90014	14	129A209   222	5144013037	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.04606	-118.25495	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 120 FA DEVICES, AND 3 FA PANELS. SUBMIT PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67565	15041-20000-23139	865 S FIGUEROA ST 16TH FLOOR	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. 6730 SQFT. 16TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67566	19041-10000-08594	28152 S WESTERN AVE #15	90732	15	024B193   622	7442030207	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.76336	-118.31049	Plan check for T24 only, Tenant Improvement to existing Restaurant. Floor area approx. 1,406 sq.ft. Power and lighting are fed from existing panel.(B# 19016-10000-05566)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67567	12041-10000-11382	1925 E 8TH ST	90021	14	123A215    48	5166031014	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Closed	03/31/2021 12:00:00 AM	ADDRESS	34.03001	-118.23777	New fire alarm, for a new market.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67568	15041-20000-06689	11256 N EL DORADO AVE	91331	7	210B153   228	2616021059	R1-1, [T][Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM	03/18/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.27444	-118.43407	Plan check for a PV1 roof-mounted PV system. System size is 3.4 kWac and consists of (16) modules, and (16) micro-inverters. Standard plan is NOT being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67569	17041-20001-15736	900 S AVENUE 60	90032	14	150A233   236	5312015066	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.02	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.10395	-118.17811	Expedite fee per applicant request.  PV1.  Install 11.56 kW DC STC roof mounted grid tied PV system.  (34) modules with 11.4 kW rated string inverter with power optimizers	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67570	11041-20000-09520	400 S HOPE ST 20th floor	90071	9	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	08/09/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	T.I. to existing high rise building partial of the 20th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67571	15041-10000-42333	2148 E BAY ST	90021	14	123A217   191	5166005010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.0314	-118.22816	T-24, TI TO AN (E) OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING FOR INDOOR AND OUTDOOR SPACES  AND NEW RECEPTACLES. TOTAL SQ. FT. 9877.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67572	13041-10000-35622	11975 W BLUFF CREEK DR BLDG#5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	33.98224	-118.40247	CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  35945 SF WITH NEW SURFACE PARKING LOT. TITLE 24 ENERGY FEE CHARGED UNDER BUILDING 3.  3 TOTAL BUILDINGS.  THIS IS BUILDING 5/5 IN THE SAME PARCELBLDG PERMIT: 13010-10000-04245	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67573	14041-20001-33767	12500 N LONGACRE AVE	91344	12	219B125   121	2601075056	RE20-1-K, RE20-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM			PC Approved	12/15/2014 12:00:00 AM	ADDRESS	34.29673	-118.53648	expedite per customer request.pv1install roof mounted pv system sized 9.8kw interconnected with msp.(32) sunpower x-21-335 modules (2) sunny boy inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67574	16041-20000-12236	12751 W MILLENNIUM A160	90094	11	102B161  1175	4211033020	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67575	14041-20000-29042	6255 W SUNSET BLVD # 850	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	PROPOSED TENANT IMPROVEMENT OF A 4000SQFT OFFICE ON 8TH FLOOR:  PC FOR T24 ENERGY ONLY. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67576	14041-10000-06539	140 N AVENUE 19	90031	1	139-5A219 127	5447015901	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	ADDRESS	34.07481	-118.22282	TI INTERIOR REMODEL OF EXISTING FIRE MAINTENANCE BUILDING TO CREATE OXYGEN TANK FILLING ROOM AND OXYGEN TANK STORAGE ROOM. Class 1 div2 location	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67577	13041-10000-03122	17430 W BLACKHAWK ST	91344	12	204B129   128	2733023023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.25835	-118.51452	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SIZE OF 10.56 KW. USING CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67578	14041-10000-24092	1306 N CORONADO TER	90026	13	141A207   177	5424023015	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.08102	-118.26659	PV1 Standard plan, 5.1 KW roof-mounted system including one Solaredge SE3800A inverter, (20) Trina Solar  TSM-255 modules and Solaredge Power optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67579	19041-20000-36240	6440 N SEPULVEDA BLVD Ste B2	91411	6	180B145   596	2235001022	C2-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.1877	-118.46585	T24 PLAN CHECK, ENERGY ONLY. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 2781 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67580	16041-10000-37507	555 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   593	2424044022	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.13776	-118.3584	PC for Title 24 controlled receptacles only, no energy plan check. Installing controlled receptacles on new gueestrooms. No lighting installed. Work being done on 1st and 21st floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67581	15041-10000-40394	801 S FIGUEROA ST 4TH FLOOR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	T-24, TI TO THE 4TH FLOOR CORRIDOR IN A HIGH RISE OFFICE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL SQ. FT. 1505.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67582	13041-20000-15596	524 N PALISADES DR	90272	11	129B117   107	4419015025	(Q)C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM			PC Approved	06/18/2013 12:00:00 AM	ADDRESS	34.04505	-118.55177	Plan check for energy and em lighting. Combine retail and tanning into restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67583	19041-10000-15821	11100 W SANTA MONICA BLVD 8TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	Energy plan check for INTERIOR REMODEL OF CORRIDOR, LOBBY, AND RESTROOMS ON THE 8TH  FLOOR OF A HIGH RISE OFFICE BUILDING. Scope includes new lighting and equipment with a total area of 793-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67584	17041-20000-46291	3274 S VETERAN AVE	90034	5	120B157   501	4254020020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	01/02/2018 12:00:00 AM		Permit Finaled	06/12/2018 12:00:00 AM	ADDRESS	34.02511	-118.42006	Plan check for AC coupled battery backup system for SFD.(1) 5kW Tesla Powerwall 2. (E) solar system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67585	15041-20001-10226	19131 W VICTORY BLVD BLDG 8	91335	3	180B121   532	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM			PC Approved	04/29/2015 12:00:00 AM	ADDRESS	34.18674	-118.55038	EXPEDITED PER APPLICANTS REQUESTPV2. ROOFMOUNTED SOLAR SYSTEM. TWO MIRRORED BUILDINGS ONE ADDRESS.  (2 OF 2 BUILDING 8 ONLY )  SYSTEM SIZE: 2. 75 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67586	19041-10000-36229	4145 N NOGALES DR	91356	3	165B121   407	2177007021	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.14684	-118.54961	pc for pv-1 system. system size is 12.060KW. system consists of (34) modules (AXITEC AC-385MH/144S) with (34) P400 optimizers. (1) 11400 inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67587	17041-30000-08112	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM			PC Approved	03/14/2017 12:00:00 AM	ADDRESS	34.0834	-118.37568	Plan check for Title 24 only. Project site is the corridors of an existing 2-story commercial building. Project scope is an interior alteration. Total lighting area = 1,658 sq. ft.Note: Building permit has been pulled under 17016-30000-03371	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67588	19041-10000-44472	265 S WESTERN AVE	90004	4	135B193   170	5517001900	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2115.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.06928	-118.30929	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67589	15041-10000-11038	19809 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	33.85117	-118.28771	T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 5679 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67590	12041-20000-26384	6310 W SAN VICENTE BLVD 1st floor	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	03/12/2013 12:00:00 AM	ADDRESS	34.06084	-118.36757	(1ST FLOOR)  Change to lighting, loads, receptacles in a Medical (Radiology) clinic.  Low rise commercial building.  Full plan check.  New MRI equipment, 400amp panel, A/C loads.  NOT STATE LICENSED, NOT CHECKED FOR OSHPD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67591	19041-10000-20324	515 S FIGUEROA ST	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Issued	08/16/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	Energy plan check for the lobby, portion of second floor, and the patio exterior (plaza level) T.I located in a high rise building. Scope includes new lighting and equipment with a total lighting area of 19,500-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67592	16041-20000-45507	5165 W FOUNTAIN AVE	90029	13	147A195   255	5544038018	R3-1, RD1.5-1XL	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Info Complete	07/17/2017 12:00:00 AM	ADDRESS	34.09528	-118.30183	"Change of use from apartment to dormitory - adding new panels, lights, controls.  New panels to reconnect to existing distribution board ""MSA"".  Plan check for power and energy.  Building permit filed under 16016-20000-31009"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67593	16041-20001-28678	7257 N PONDERA CIR	91307	12	183B093    44	2027012005	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.20155	-118.64219	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a SFD. Interconnect with a 150A MSP. Derating main breaker to 100A. 7.6kW ungrounded system. (29) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67594	18041-20001-32752	12711 N BROMONT AVE	91340	7	219B157    34	2513015043	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM			PC Approved	08/31/2018 12:00:00 AM	ADDRESS	34.30091	-118.42633	Revisions to approved set for wiring detail changes.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67595	18041-10000-04611	11766 W WILSHIRE BLVD STE 100	90025	11	129B145   734	4263008062	(T)(Q)C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.04804	-118.46227	PC FOR TITLE 24 ENERGY ONLY FOR BANK (CHASE) LIGHTING MODIFICATION. INTERIOR WORK ONLY. TOTAL AFFECTED AREA 6199 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67596	15041-10000-03980	1901 S AVENUE OF THE STARS Suite 1040	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	34.05949	-118.41705	Title 24 plan check only.  Total area = 2,576 sq. ft.T.I. to existing commercial office space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67597	18041-20000-11755	6515 S MCKINLEY AVE	90001	9	105B205  1257	6007017017	MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	01/31/2020 12:00:00 AM		Issued	01/31/2020 12:00:00 AM	ADDRESS	33.97996	-118.26153	2500A 480Y/277V 3ph-4w service, distribution, power, and lighting for commercial building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67598	13041-20000-06735	8901 N CANOGA AVE	91304	12	195B105   360	2779047020	[Q]MR1-1VL, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			03/15/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.23186	-118.59777	Plan check for energy only. UPS room for a commercial space. Low-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67599	15041-20001-31594	12056 N ADELPHIA AVE	91340	7	216B161   105	2514005038	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2015 12:00:00 AM			PC Approved	10/23/2015 12:00:00 AM	ADDRESS	34.28948	-118.41235	expedite per applicant requestPV1Install a roof mounted solar array on a SFD. Interconnect with a 100A MSP.Ungrounded system. Using 300W power optimizers (1 per module). (18) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67600	18041-10000-34200	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	08/03/2020 12:00:00 AM	ADDRESS	34.02201	-118.28947	RELOCATION OF EXISTING PANELS AND LOADS IN CLEANROOM AND HPM AREA OF USC MCB BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67601	19041-10000-07934	17461 W VENTURA BLVD	91316	5	171B129   410	2257016054	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Issued	03/05/2019 12:00:00 AM	ADDRESS	34.16157	-118.51326	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67602	19041-10000-06960	4750 W WILSHIRE BLVD	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM			PC Info Complete	02/26/2019 12:00:00 AM	ADDRESS	34.06185	-118.3338	INTERIOR T.I FOR IN EXISTING ELEVATOR LOBBY AND INSTALLING MINIMUM LIGHTING IN FUTURE OFFICE SPACE ON THE FIRST FLOOR OF AN EXISTING 3 STORY LOW RISE OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67603	16041-20000-07780	1212 S FLOWER ST	90015	14	126A207    34	5138026030	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Issued	07/22/2016 12:00:00 AM	ADDRESS	34.04113	-118.26555	Plan check for temporary power. Service size is 3,000 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67604	18041-20000-14161	3831 S HUGHES AVE 104	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.02242	-118.39823	ti to an existing medical office building, consultation only.  adding new lighting new controls to new panel.  newly connected load <400 amps.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67605	15041-20000-17935	11613 W CLOVER AVE	90066	11	120B153   999	4250008013	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.02279	-118.43653	Plan check for PV roof mounted system. System size: 4.56kW microinverter(Enphase) and 16 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67606	16041-10009-38001	4061-4065 S GLENCOE AVE	90292	11	108B153  1016	4230004028	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	33.99055	-118.44379	"CHANGES TO AN APPROVED SET OF PLANS.  ALL CHANGES ARE CLOUDED UNDER DELTA 3. CHANGES INCLUDE SPECIFYING FEEDER CONDUCTOR SIZE FROM ""APMP"" DISTRIBUTION BOARD TO ""LIFT 1"" AND ""LIFT 2"". CHANGES TO REFLECT AS BUILT.  NOTE: PERMIT HAS BEEN PAID UNDER PCIS#16041-10000-38001"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67607	19041-30000-03490	1736 S SEPULVEDA BLVD	90025	5	129B153   950	4323020035	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.04663	-118.44316	Plan check for energy only. Project site is an existing commercial building. Project scope is a change of use from animal hospital to print shop on the first floor. Total lighting area = 7,035 sq. ft.Note: Building permit has been issued under 17016-10000-05216	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67608	11041-10002-23439	20600 W VENTURA BLVD North-1-123	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			03/28/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	DELTA 10 CHANGES TO PERMITTED SET OF PLANSLISTS OF CHANGESARE ATTACHED TO PLANSThe garage site is included in plan.North Building of a New 123 unit Apartment building with Commercial space.  1200A service for Commercial space and 2000A service for apartment space.  Building Permit is 11010-10000-01958	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67609	17041-20000-34891	750 S KINGSLEY DR	90005	10	132B193   551	5093025003	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM	07/24/2020 12:00:00 AM		Permit Finaled	07/28/2023 12:00:00 AM	ADDRESS	34.0583	-118.30294	Plan check for power and energy. New 6-story, 67-unit apartment building. 2,000A 120/208V 3ph 4w service. 4 typical units. T24 area - 44,587sqft.Building permit 16010-10000-05352 issued.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67610	17041-10000-35931	2435 S SEPULVEDA BLVD	90064	5	123B153   158	4256010013	(T)(Q)C2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	05/28/2020 12:00:00 AM				PC FOR TEMP POWER FOR HIGH RISE. TEMP SERVICE 2500 277/480VSCOPE INCLUDES EQUIPMENT, PANELS AND CIRCUITS. CONDUIT PERMIT PULLED UNDER 17041-90000-31783CORE AND SHELL UNDER 16041-20000-36167	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67611	15041-10011-07080	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 40 ON PLANS. CHANGED OUT SMALLER HVAC UNITS TO LARGER SINGLE PACKAGE UNITS. PROVIDING NEW PANELS FOR FUTURE USE. SMALL RECIRCUITING ON FLOOR PLANS. ALL CHANGES CLOUDED. PC AND PERMIT FOR ALTERED WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67612	12041-20000-14132	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	T.I. to high rise building partial of 20th floor.  Install general/emergency lighting in rooms 2047-2048, 2050-2059 as indicate on the plans.  Plan check for energy only.Note: Permit issued under 12041-20000-14134	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67613	11041-10000-21081	11150 W SANTA MONICA BLVD 5th Floor	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Info Complete	10/21/2011 12:00:00 AM	ADDRESS	34.04704	-118.44563	T.I. to the entire 5th floor of an existing high rise building.  Plan check for ENERGY and POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67614	19041-20000-17642	3625 W SENECA AVE	90039	13	156B209   211	5435001005	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.12139	-118.25846	PV1.  Install 6.93 kW roof mounted grid tied PV system with 13.5 kWh energy storage system.  (21) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67615	17041-10000-11815	11011 W OTSEGO ST 1-144	91601	2	171B173   838	2353007052	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.16308	-118.37103	New Fire alarm installation for 144 unit apartment building  ( not a high-rise)Total device count 400	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67616	16041-20000-35369	13630 W SAYRE ST	91342	7	225B157   505	2510017033	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.31337	-118.42993	Plan check for installation of solar system on SFD, roof-mounted. Interconnect with a 200A MSP. Derating main breaker to 150A. 5kW ungrounded system. (22) 255W pv modules. Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67617	12041-10000-19445	21505 W RINALDI ST	91311	12	210B105   275	2723004020	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.11	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM			Reviewed by Supervisor	09/13/2012 12:00:00 AM	ADDRESS	34.27132	-118.59951	PLAN CHECK POWER AND ENERGY. NEW 2 STORY CLASSROOM BLDGS (BLD 4 &BLD 5) FOR CHARTER SCHOOL. MAIN 2000A SERVICE AND SERVICE EQUIPMENT LOCATED NEW BLD 4. (APPLICATION 5 OF 6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67618	18041-20000-16413	14901 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29444	-118.45518	Plan check for PV roof mounted system size: 3.8kW with 12 modules and 1 inverter (3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67619	17041-10000-31929	1335 E WILLOW ST	90013	14	126A217    72	5164006014	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.0394	-118.23145	PC FOR RESTAURANT TI (CONVERT PORTION OF EXISTING MANUFACTURING BUILDING ( MEAT PACKING ) TO TAKE-OUT RESTAUARANT ( NO STTING )) FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 377 SQ.FT.SCOPE INCLUDES NEW PANEL CIRCUITS LIGHTS EQUIPMENT AND RECEPTACLES.Elecctrical permit was pulled under X17LA15058B# 17016-10000-12062	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67620	19041-20000-31476	10309 W WASHINGTON BLVD	90232	5	117B165   173	4208005012	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.01941	-118.40154	Plan check for Title 24 Energy only Tenant Improvement commercial space. Total area: 3195 sq ft. B#19016-70000-08236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67621	16041-10000-17659	1710 W CORDOVA ST	90007	1	126B197   889	5075037026	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.0389	-118.29487	TITLE 24 ONLY  TOTAL 12512 SQFT REMOVE HID  FIXTURE AND REPLACE WITH NEW LED FIXTURES  (20 UNITS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67622	13041-10000-24071	10244 N WOODLEY AVE	91343	12	204B141   390	2669007018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Expired	09/30/2015 12:00:00 AM	ADDRESS	34.25673	-118.48466	PLAN CHECK # WILL BE ASSOCIATED WITH BOTH PLAN CHECKING AND PERMIT #:PV1 ROOF MOUNTED SOLAR INSTALLATION ON STANDARD PLAN. SYSTEM SIZE IS 7.5 KW DC AND 7.5 KW AC. [MODULES: TRINA SOLAR # TSM-250 PC/PA05 |||| INVERTER: FRONIUS # IG PLUS V7.5]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67623	13041-10000-12077	3607 S TROUSDALE PKWY	90089	8	118-5A201   1	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.02013	-118.28566	Replacement of an existing fire alarm panel and initiating devices at Ronald Tutor Campus Center.  3 new fire alarm panels.  427 initiating devices and 3 fire alarm control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67624	15041-10000-15652	111 E UNIVERSAL HOLLYWOOD DR 34th  FLR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.13855	-118.36112	Energy plan check for 34th floor office T.I. Scope includes a completed demolation for the whole floor except exising panels and transformers; all circuits, lighing and receptacles will be new.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67625	15041-10000-35247	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	33.98076	-118.40716	CORE AND SHELL TO A  6 STORY, OFFICE BUILDING OVER GROUND LEVEL PARKING GARAGE ON PARCEL 2 ON THE CAMPUS OF PLAYA VISTA.  LOCATED IN A METHANE ZONE. NEW 2500 AMP SERVICE.  PC FOR ENERGY AND POWER, TOTAL SQ. FT. 199000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67626	13041-10001-02011	5500 S VERMONT AVE	90037	9	108B197   820	5001009013	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	04/30/2013 12:00:00 AM	ADDRESS	33.9922	-118.2913	CHANGES TO APPROVED SET OF PLANS. change the size of feeders to panels from #1 to #2Plan check power and energy existing commercial building. New 800A service and equipment for future retail spaces in building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67627	18041-20000-44155	2444 N CHEREMOYA AVE	90068	4	154-5A189 484	5580005016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	Apartment			11/19/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Issued	12/18/2018 12:00:00 AM	ADDRESS	34.11571	-118.32102	PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 6 MODULES (SW 325 XL MONO) AND 6  MICROINVERTERS.  SYSTEM SIZE IS 1.95KWdc and 1.68KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67628	17041-10000-14138	3263 N PRIMERA AVE	90068	4	159B181   601	5579018020	R2-1XL	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Issued	04/28/2017 12:00:00 AM	ADDRESS	34.13003	-118.34507	PC FOR PV SYSTEM RATED 10KW AC USING CENTRAL INVERTER AND 26 MODULES. system is rooftop mounted	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67629	15041-10003-16492	24500 W PAT PL	91367	3	177B085   536	2032014002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2015 12:00:00 AM			PC Approved	10/08/2015 12:00:00 AM	ADDRESS	34.17822	-118.65852	CHANGES TO AN APPROVED SET OF PLANS.  DOWNSIZE (1) INVERTER FROM 5KW TO 3.8KW.THIS IS PLAN CHECK ONLY.PV1, INSTALL 14.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(43) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-3.8 AND PVI-3.8 AND PVI 5000-OUTD -US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67630	15041-10000-34031	2049 S CENTURY PARK EAST 11TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24, TI TO THE 11TH FLOOR ON A (E) HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER TO OPEN OFFICES ONLY. TOTAL SQ. FT. 2185.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67631	10041-20000-18321	440 S VERMONT AVE #111	90020	13	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM			PC Info Complete	10/01/2010 12:00:00 AM	ADDRESS	34.0659	-118.29143	First time tenant to a new building (Cell Phone Village).  Plan check for energy and power. Suite #111	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67632	14041-20000-33860	11680 W VICTORY BLVD	91606	2	180B169  1212	2335027002	C1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Expired	06/29/2018 12:00:00 AM	ADDRESS	34.18651	-118.38718	Plan check for ENERGY ONLY. Remodel to convert (E)27' x 61' service station to (N)mini mart. All work interior to building (no power being routed through/to hazardous location/service pumps). 1,513sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67633	18041-10000-47871	930 S MANSFIELD AVE	90036	4	132B181   604	5084006006	R3-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			Reviewed by Supervisor	01/16/2019 12:00:00 AM	ADDRESS	34.05789	-118.34211	FULL PC FOR APARTMENT COMPLEX (19 UNITS). SERVICE SIZE IS 1200A, 120/240V, 3PH. PC INCLUDE PWR AND LTG. TOTAL OF 452KVA LOAD.B#18010-10000-06010	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67634	14041-20000-11158	7228 W BEVERLY BLVD	90036	5	138B181   445	5512023001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Expired	07/12/2016 12:00:00 AM	ADDRESS	34.07598	-118.34719	T.I. to existing building for American Apprarel store.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67635	13041-10001-33078	7957 N KENTLAND AVE	91304	12	189B097   455	2013010040	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			Verifications in Progress	04/11/2014 12:00:00 AM	ADDRESS	34.21532	-118.61784	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67636	13041-20000-26928	725 S FIGUEROA ST 2nd Floor	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.04886	-118.26071	T24 FOR HIGHRISE OFFICE BUILDING. SCOPE OF WORK ON 2ND FLOOR. TOTAL SQRFT 20815. TOTAL LOAD LESS THAN 400A PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67637	14041-20000-24864	7006 S HOOVER ST UNIT 6	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #6.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67638	18041-10000-01218	355 S GRAND AVE 28th FLR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	Energy plan check for a corridor in a high rise commercial office.  Scope includes new lighting and receptacles. Total area is 2629 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67639	10041-10000-06179	888 S FIGUEROA ST SUITE #770	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	05/04/2010 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI IN AN EXISTING OFFICE AREA IN SUITE # 770. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67640	11041-10000-10390	637 W WILSHIRE BLVD	90017	9	129A209    71	5144005031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/20/2011 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	09/17/2012 12:00:00 AM	ADDRESS	34.04869	-118.25681	elev rel and notification devices, high rise.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67641	17041-10000-11541	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.06664	-118.46903	PC FOR POWER AND ENERGY FOR NEW SCHOOL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67642	14041-20001-14189	12036 N WOOD RANCH ROAD	91344	12	216B129    91	2601068003	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	34.2904	-118.52416	EXPEDITE PER APPLICANT REQUEST[[[PV1Install a 6kW solar array on roof of SFD.(1) SMA SB6000US-12 transformed inverter(20) Sunpower SPR-x21-345 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67643	19041-20000-09006	10705 N HILLROSE CIR	91040	7	207B189   709	2547010039	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.26315	-118.32503	Plan check for installed battery energy storage system into existing PV system, Energy Storage System size: 40.5KWh  with 3 Tesla PowerWall 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67644	14041-10000-02427	222 N LAGOON AVE	90744	15	027B205   297	7418035018	M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	33.77163	-118.26686	Remove HID light fixtures and replace with new fluorescent fixtures in a commercial work space.  Title 24 plan check for fixture one-for-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67645	10041-20000-18150	12021 W KLING ST	91607	2	168B165   630	2355014127	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Apartment			09/14/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	04/14/2011 12:00:00 AM	ADDRESS	34.15593	-118.39504	New fire alarm system for existing building (4 floors over a garage floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67646	15041-20000-36023	8401 N LAUREL CANYON BLVD	91352	6	192B165   345	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.22336	-118.39661	PLANCHECK FOR TITLE 24 ENERGY. TENANT IMPROVEMENT FOR CARLS JR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67647	10041-10000-05484	1241 N VINE ST	90038	13	144B185   204	5533005001	C2-1D, RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM			PC Info Complete	04/01/2010 12:00:00 AM	ADDRESS	34.09373	-118.32682	TITLE 24 AND EMERGENCY LIGHTING , NO HIGH RISE , COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67648	12041-10000-03659	800 W 6TH ST	90017	9	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.05011	-118.2577	PLAN CHECK POWER AND ENERGY FOR RESTAURANT ON FIRST FLOOR IN A HIGH RISE BUILDING. ORIGINAL PLAN CHECK UNDER #11041-10000-24522. SCOPE OF NEW PLAN CHECK CHANGE MORE THAN 50%.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67649	13041-20000-29542	15303 W VENTURA BLVD SUITE 1100	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.15413	-118.46661	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 1100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67650	19041-10000-18555	646 S SAN PEDRO ST	90014	14	126A213    85	5147026032	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Issued	05/17/2019 12:00:00 AM	ADDRESS	34.04108	-118.24609	Remove HID fixtures and replace with new LED fixtures (Indoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67651	14041-20000-31165	11811 N PASO ROBLES AVE	91344	12	213B133    37	2607002023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.2845	-118.50341	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(12) SUNPOWER 327 MODULES (1) PVI 3.8 OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67652	18041-10000-27846	7400 N COLDWATER CANYON AVE	91605	2	186B161   521	2324001011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1216.00	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			Reviewed by Supervisor	08/06/2018 12:00:00 AM	ADDRESS	34.20498	-118.41362	Install Rofftop solar system in a Commercial Building, Build.-A. System size, 20.060 kWptc/ 19.759 kW CEC/ 20kW AC. (68) modules, (68) optimizers, (2) central string inverter, (1) 600A panelboard/load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67653	16041-20000-40355	18771 W WILLOWTREE LANE	91326	12	207B121   529	2728029072	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.26304	-118.54197	Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (42) modules, (42) micro-inverters, and (1) combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67654	14041-20000-34790	1000 W WILSHIRE BLVD Suite 1140	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	Plan check for energy only. TI to existing office on 11th floor of highrise office building. New lighting (incl. emergency) and receptacles. 3,168sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67655	12041-10000-17822	6511 1/2 W LA MIRADA AVE	90038	4	144B185  1329	5533002064	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM			Corrections Issued	07/31/2012 12:00:00 AM	ADDRESS	34.09359	-118.33152	Plan check for roof mounted 1.5KW photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67656	17041-10000-41776	4008 N GRIFFIN AVE	90031	1	144A225   154	5207017004	[Q]RD3-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.0897	-118.20558	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER. (13) MODULES AND OPTIMIZERS AND (1) INVERTER. TOTAL SYSTEM SIZE IS 3.8KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67657	17041-10000-41805	644 S GLADYS AVE	90021	14	126A213   413	5147030064	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.03913	-118.24292	NOTE: FEES ARE $0 DUE TO SENATE BILL 1222.PV2, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND STEP DOWN TRANSFORMER TO 240V. (198) MODULES (3) 20KW INVERTERS. TOTAL SYSTEM SIZE IS 60KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67658	19041-30001-07910	601 S FIGUEROA ST 13th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	03/12/2019 Changes to an approved set of plans. Scope of work has expanded to include the elevator lobby. Total lighting area is now 18,485 sq. ft. Title 24 forms have been updated.*****Original Scope of Work*****Plan check for Title 24 only. Project site is the 13th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 18,225 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67659	19041-20000-29875	7324 W MELROSE AVE	90046	5	141B181   615	5526021026	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.08342	-118.34957	Plan check for Title 24 only, Tenant Improvement  to take out restaurant. Total area: 875 sq ft. B#19016-30000-10397	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67660	14041-20000-31646	1677 N LUCRETIA AVE	90026	13	142-5A209 242	5419004017	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.0837	-118.25477	PV1. ROOFMOUNTED SOLAR SYSTEM. 3.9 KW DC.(12) SUNPOWER 327W MODULES(1) POWER ONE PVI-4.2 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67661	14041-20000-17966	7369 W CHANTILLY CT	91042	7	210B197   534	2552048021	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.2727	-118.29345	PV1Install roof mounted solar array on SFD. System size: 4.3kW(20) EnPhase M215 microinverters(20) SW 270 Mono pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67662	15041-20000-13843	22439 W PACIFIC OAK DR	91311	12	201B101   258	2727004032	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.24773	-118.6159	PV1 SFD. TOTAL SYSTEM SIZE 7.3KW AC USING 34 MICROINVERTERS. USING ENPHASE M215. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67663	18041-10000-11935	2777 E WASHINGTON BLVD	90023	14	118-5A221  97	5169016014	M3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.01746	-118.22062	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67664	11041-20000-20137	807 N LA CIENEGA BLVD	90069	5	141B173   195	4337002037	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM			PC Approved	09/21/2011 12:00:00 AM	ADDRESS	34.08546	-118.37673	Plan check for T24 Energy retail space in an existing building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67665	16041-10000-13289	19503 S NORMANDIE AVE	90501	15	060B193   443	7351002030	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	33.85617	-118.3012	New lighting. Plan check for Title 24. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67666	14041-20000-23773	5143 N DENSMORE AVE	91436	5	171B141   220	2261015035	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.16329	-118.47731	$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.  PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(54) KYOCERA KD 255 MODULES(2) SOLAR EDGE SE 6000 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67667	15041-10000-08954	1000 E WASHINGTON BLVD #120- 125	90011	9	121-5A211 373	5131008048	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Closed	01/19/2016 12:00:00 AM	PIN	34.02543801	-118.2533304	TI TO AN EXISTING COMMERCIAL BUILDING (FITNESS GYM).  NEWLY CONNECTED LOAD >400.PLAN CHECK FOR POWER AND ENERGY. FIRE VARIANCE ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67668	19041-10000-47365	19101 W ENADIA WAY	91335	3	183B121   191	2129002011	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	34.20024	-118.54943	NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 8.23KW DC/ 7.54 KW AC, WITH A CENTRAL INVERTER (SE6000H-US), 27 MODULES (HANWHA Q-CELL), AND 27 POWER OPTIMIZERS (P320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67669	19041-10000-34518	4343 N LANKERSHIM BLVD 1st Floor	91602	4	165B177   566	2423019075	C2-1VL-CDO-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Info Complete	12/14/2020 12:00:00 AM	ADDRESS	34.14909	-118.36531	FULL PLAN CHECK FOR A TENANT IMPROVEMENT - 1ST FLOOR - MEDICAL OFFICE SUITE IN EXISTING 3 STORY BUILDING, OUTPATIENT MEDICAL CARE: AMBULATORY SURGERY CENTER. SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 5693 SQ.FTNOTE: THE SERVICE CHANGE IS RECORDED UNDER E19LA05531	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67670	11041-20000-12115	6902 W SANTA MONICA BLVD	90038	4	144B181   478	5532029013	MR1-1	Central	Hollywood	Central Hollywood		1919.00	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.09049	-118.34078	Plan check power and energy for tenant improvement of an existing 1-story.  New 800A service electrical system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67671	18041-10000-41101	100 WORLD WAY Hudson-180	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT FOR EXISTING RETAIL SPACE.  Hudson - TOTAL AFFECTED AREA 347 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67672	16041-10000-18168	14403 W TIARA ST	91401	4	177A151   153	2245002015	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	Apartment			05/24/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.1786	-118.44664	PC FOR ENERGY AND POWER. NEW 3-STORY CONDO BUILDING WITH 8 UNITS. 600 AMP OVERHEAD SERVICE TOTAL AREA 4000 SQ FT FOR T-24. B# 13010-10000-00680	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67673	19041-20000-23194	5700 W WILSHIRE BLVD SUITE 285	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM			PC Info Complete	06/18/2019 12:00:00 AM	ADDRESS	34.06218	-118.35303	Plan check for Title 24 only in existing high rise building, Tenant Improvement. Total area: 3572 sq ft. B#19016-10000-10565	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67674	16041-10000-45174	935 S MAIN ST	90015	14	126A209    25	5139002005	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.04108	-118.25616	Plan check for Title 24 only in existing building T.I. Total load less than 400A Total area: 5,047 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67675	11041-10000-06535	2000 W SAN FERNANDO ROAD NORTHEAST ROADWAY	90039	1	148-5A215 333	5442002001	[Q]M2-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			PC Approved	11/21/2011 12:00:00 AM	PIN	34.10158834	-118.23689483	T-24 ONLY FOR 110,000 SQ. FT. WAREHOUSE.  PERMIT IS ALREADY PULLED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67676	18041-10000-41090	249 S LOS ANGELES ST	90012	14	129A213    47	5161026910	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	06/30/2020 12:00:00 AM	ADDRESS	34.04908	-118.24445	PC FOR NEW FA  SYSTEM IN COMM. BUILDING ( 2 STORY). SCOPE INCLUDES 3 PANELS AND 72 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67677	16041-10000-36665	10100 W SANTA MONICA BLVD FLR 24	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	02/25/2017 12:00:00 AM	ADDRESS	34.06191	-118.41691	PC FOR TITLE 24.ENERGY ONLY SCOPE INCLUDES NEW LIGHTING AND NEW RECEPTACLESTOTAL AFFECTED AREA 22166 SQ.FT************************************************************************************BLD APP # 16016-10000-21411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67678	16041-10000-05433	8400 N BALBOA BLVD north bldg	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	04/08/2019 12:00:00 AM	ADDRESS	34.22376	-118.50243	one of two new buildings with retail tenant spaces-SHELL/CORE ONLYThis North Building (16010-10000--00456) plans will be reviewed under this application.A separate application will be required for plan review of the plans for the West Building (16010-10000-004550)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67679	16041-10000-36754	4929 N EAGLE ROCK BLVD	90041	14	160-5A221  36	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.13592	-118.21529	PC FOR YOGURT SHOP. NEW LIGHTING. PC FOR ENERGY ONLY T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67680	19041-20000-08771	3441 N CAHUENGA BLVD	90068	4	159B177   374	2425025008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.13207	-118.35326	PV1.  NEW 10.8 KW DC / 9.18 kW AC ROOFTOP PV SYSTEM ON (E) RESIDENTIAL SERVICE. SCOPE OF WORK INCLUDES 30 360W SUNPOWER MODULES WITH INTEGRATED MICROINVERTERS, (1) 200A SERVICE SUB PANEL, AND (1) 125A PV DISTRIBUTION PANEL.$0 PERMIT FEE PER STATE SENATE BILL SB 1222 AND STATE ASSEMBLY BILL AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67681	14041-10000-31309	505 S VIRGIL AVE Suit 301	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.0649	-118.28724	plan check for power and energy. T.I full plan check for Medical office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67682	15041-20000-22588	7605 COURAGE WAY	91405	6	186B145  1155		(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	PIN	34.20878921	-118.46444921	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter, (18) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67683	13041-20000-16988	11355 W DONA LOLA DR	91604	2	159B173   346	2380015011	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Finaled	07/09/2013 12:00:00 AM	ADDRESS	34.13241	-118.37853	New 5.2kw PV System using Enphase microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67684	16041-20001-01124	530 W 6TH ST #720	90014	14	129A209    78	5144004012	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	01/22/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.04853	-118.25518	Plan check only for scope of work expansion - now includes addition of one dual power fed exit sign.  (6) communication devices  added per inspector request.  (((ADD RECEPTICLES AND LOW VOLTAGE WIRING.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67685	15041-20000-04579	8635 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM			Reviewed by Supervisor	04/01/2015 12:00:00 AM	ADDRESS	34.07373	-118.38073	VOID APPLICATIONPLANCHECK FOR T24 ENERGY FOR COMMON AREA.  CMSC MEDICAL OFFICE TOWERS. UPGRADES TO CORRIDORS LOBBIES AND RESTROOMS; ALSO ACCESSORIES AND FINISHES. ALL WORK DONE TO 1ST, 2ND, AND 3RD FLOOR ONLY.  SUBMITTED TO BACK ROOM PLANCHECK PER APPLICANTS REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67686	11041-10007-02930	1717 N GARFIELD PL	90028	13	148-5A193 110	5544003002	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			10/22/2012 12:00:00 AM			PC Approved	10/22/2012 12:00:00 AM	ADDRESS	34.10227	-118.31103	Delta 12 modification  to the meter/main switchborad elevation showing bus transition sections 1 and 2.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67687	19041-30000-14191	601 S FIGUEROA ST 21st Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site are the common area restrooms on the 21st floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 550 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67688	14041-10000-28438	633 W 5TH ST Level 2	90071	14	130-5A209 144	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR US BANK BUILDING. LEVEL 2.(((notified by email. phone number may be wrong)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67689	12041-10000-28971	6263 W DE LONGPRE AVE Phase 2	90028	13	147A189   139	5546023031	R4-2D	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			12/03/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.09628	-118.32592	in a parking lot ,installing 2ea post-supported luminairesplan check is for title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67690	19041-10000-35831	1827 S MIDVALE AVE 1-17	90025	5	129B153   690	4323006027	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	02/10/2021 12:00:00 AM	ADDRESS	34.04855	-118.43747	FIRE ALARM SYSTEM FOR 5-STORIES 17 UNITS APARTMENT BUILDING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67691	17041-10000-32586	1800 CENTURY PARK EAST 12 th flr	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	PIN	34.06270629	-118.4150769	PC FOR OFFICE T.I.  IN A HIGH RISE BUILDING.  SCOPE  OF WORK INCLUDES NEW FIXTURE AND NEW RECEPTACLES (ON NEW CIRCUITS). TOTAL AFFECTED AREA 4500SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67692	15041-10000-11799	758 S MAIN ST	90014	14	127-5A211 219	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Closed	12/31/2015 12:00:00 AM	ADDRESS	34.04275	-118.25284	Energy plan check for a change of use from retail to a restaurant.  Plan check is under 2008 Energy code due to building permit is submited before July 1, 2014.  A portion of electrical permit fee is already paid under permit # 15041-10000-04223. Building permit Reference # 12016-10000-18056.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67693	19041-10000-10618	19191 S VERMONT AVE STE. 680	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	T-24, ENERGY ONLY PLAN CHECK FOR A TENANT IMPROVEMENT IN AN OFFICE SPACE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 4208SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67694	12041-20000-00604	1006 E 28TH ST 1-49	90011	9	118-5A209 315	5128022009	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	12/31/2012 12:00:00 AM	ADDRESS	34.01717	-118.2574	Per applicant, new wall mounted PV system with 38.7 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67695	10041-10000-24674	13141 N PHILLIPPI AVE	91342	7	222B153    16	2504016042	RA-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2010 12:00:00 AM			PC Approved	01/03/2011 12:00:00 AM	ADDRESS	34.30932	-118.44259	Photo voltaic system on roof of dwelling PLAN REVIEW IS FOR PLAN CHK ONLY  AS Permit WAS obtained on 09041-30000-17805	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67696	10041-20000-05687	3800 W MT LEE DR	90068	4	159B189    10	5581010900	OS-1XL	Central	Hollywood	Greater Griffith Park, Hollywood United	YES	1897.01	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.13546	-118.3184	ADD REMOTE ANNUNCIATOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67697	16041-10000-22112	535 W EL SEGUNDO BLVD	90248	15	081B201   252	6132002022	R3-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	Apartment			06/23/2016 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.91658	-118.284	Full Plan Check for NEW four-story 75-units apartment. 2000A service, total area: 57,255 sq.ft. There are 5 Typ. units. Build. located in the methane zone.  * Fire alarm varience is filed with this submittalB# 16010-10000-02632	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67698	16041-20001-40390	11529 W STAGG ST	91605	6	189B169   607	2311011033	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Approved	11/19/2016 12:00:00 AM	ADDRESS	34.2126	-118.38282	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 18.6 kWac and consists of (54) AC modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67699	13041-20001-23761	7713 N LOMA VERDE AVE	91304	3	189B109  1072	2109021009	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.21038	-118.58976	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.6 KW USING 22 MODULES TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67700	16041-10000-20106	14526 W ERWIN ST	91411	6	178-5A151 277	2241013008	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.18352	-118.44975	PC for T-24 only, remove HID fixtures and replace with LED fixtures. Total area: 4000 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67701	16041-10000-03732	4954 N WHITE OAK AVE	91316	5	168B129   767	2290010024	(T)RS-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.16089	-118.518	PV1, SOLAR ROOF MOUNTED SYSTEM USING MICRO-INVERTERS. (46) MODULES AND (46) MICROINVERTERS AND (100AMP) LOAD CENTER WITH A MONITORING SYSTEM. TOTAL SIZE 11.5KW-AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67702	15041-20000-00542	5244 N VINELAND AVE	91601	2	171B173   423	2416004011	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			01/08/2015 12:00:00 AM			PC Approved	01/08/2015 12:00:00 AM	ADDRESS	34.16618	-118.37015	PLANCHECK FOR T24 ENERGY. NEW BUILDING. WAREHOUSE. , 400 AMPS NEWLY CONNECTED LOAD. 4000SQFT. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67703	13041-10000-16723	3553 E BESWICK ST	90023	14	120A227   144	5191012031	(T)(Q)RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Apartment			06/24/2013 12:00:00 AM	06/24/2013 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.02223	-118.19931	installation of fire warning system with central station monitoring	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67704	19041-10000-42481	9870 N SAN FERNANDO ROAD 101	91331	7	201B165    56	2537015042	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Issued	03/06/2020 12:00:00 AM	ADDRESS	34.25001	-118.40419	PLAN CHECK FOR POWER AND ENERGY - SCOPE INCLUDE ADDITION OF NEW LOAD OF APPROX 300A, AND TITLE 24 WITH A TOTAL AFFECTED AREA OF 1742 SF.(((ADDITIONAL INFORMATION TO BE REMOVEDAGRICULTURAL TESTING FACILITY - MINIMAL AMOUNT OF HAZARDOUS AREAS WITHIN FACILITY)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67705	14041-10000-31659	3423 N ALGINET DR	91436	5	159B137   346	2287010047	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.13223	-118.4974	PV1.  Installation of 6.540 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67706	19041-10000-09168	120 S JAPANESE VILLAGE PLAZA MALL	90012	14	129A215    54	5161017033	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.0489	-118.2399	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67707	17041-20000-19492	221 S FIGUEROA ST Ste 410	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.05628	-118.25373	Commercial highrise office TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67708	15041-20000-32040	5335 N LEMP AVE	91601	2	171B169   181	2348006052	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.16758	-118.38473	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 7.6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67709	16041-10000-33650	3185 E WASHINGTON BLVD	90023	14	117A223    39	5169020003	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	12/05/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.01526	-118.21058	$0.00 permit fee due to California State Senate Solar Bill 1222Installation of a roof mounted solar system in a commercial storage building. Installing 12 string inverters rated at 33.3Kw each for a total system size of 399.6 Kw. Installing 1534 solar modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67710	18041-20000-19461	201 S OCEAN FRONT WALK	90291	11	109-5A141  65	4286030001	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	05/25/2021 12:00:00 AM	ADDRESS	33.99521	-118.48087	Change of use from one story dance hall to commnity center and two story addition of community center and single family dwelling on third floor.  New 600A 240/120V 3ph-4w service.  Building permit under 17014-10000-04862.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67711	13041-10000-18409	17417 W NORDHOFF ST	91325	12	198B129   422	2766011055	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	09/26/2013 12:00:00 AM	ADDRESS	34.23599	-118.51374	INSTALLING ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING WITH EXISTING MAIN PANEL FOR A 2- STORY HOUSE. SYSTEM SIZED AT 10.29KW.  MODULE SPECS, TRINA #TSM-245PC05/PA05. INVERTER 1 : DC NEGATIVELY GROUNDED, INVERTER 2 : DC NEGATIVELY GROUNDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67712	18041-20000-29316	17415 W MAYERLING ST	91344	12	213B129    80	2601041062	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.28323	-118.51367	PV1.  Plan check for PV roof mounted system, sysem size: 18.0kW with 50 PV AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67713	18041-10000-04279	7800 W SUNSET BLVD	90046	4	147B177  1001	5551025025	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.09789	-118.35952	PC for T24 only for replacement of metal halide fixtures with new LED fixtures in outdoor areas. Total area 30445sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67714	14041-20000-19259	881 E WARREN AVE	90291	11	111B145   205	4243013027	R1-1	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.00318	-118.4664	PV1Microinverter standard plan. Install roof mounted solar array on detached garage of SFD. System size: 3.024kW. (14) Enphase M215 microinverters. (14) Sun Edison F260 pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67715	19041-10002-31286	9215 W CATTARAUGUS AVE	90034	5	123B165   206	4301002007	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM			PC Approved	09/23/2019 12:00:00 AM	ADDRESS	34.03591	-118.39277	09/23/2019Changes to an approved set of plans, changes include the removal of a module and layout on the roof. Total system size is 6.93 kwdc / 7.6 kwac . __________________________________Change to an approved set by rearrange the number of module and the layout on the plan.(((pv-1 for 22 modules (panasonic VBHN330SA16) WITH OPTIMIZERS (SOLAREDGE P400). INVERTER (SOLAREDGE SE7600H-US). )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67716	18041-20000-41244	6080 W CENTER DR Ste 1200	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	33.97713	-118.39172	Commercial office TI in a highrise building.  Plan check for energy - 22,100 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67717	11041-20000-14275	333 S GRAND AVE 32ND FL	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.05271	-118.25179	T24 ENERGY GENERAL/EMERGENCY LIGHTING TI FOR LUNCH ROOM/STAFF LOUNGE ON THE 32ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67718	11041-20000-16546	1880 CENTURY PARK EAST 5th fl	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	08/23/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	energy plan check # 5th fl cooridoor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67719	19041-10000-43393	1201 N GOWER ST	90038	13	144B189   254	5534004001	R3-1, R3-1XL	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.09312	-118.32242	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLY (INDOOR AND OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67720	16041-10005-35848	331-335 S BROADWAY	90013	14	130-5A211 111	5149015018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.05037	-118.24893	DELTA 5 CHANGES TO APPROVED PLANS FOR RELOCATION OF EQUIPMENT, ADDING NEW CKTS, CHANGING LIGHTING DESIGN AND OTHER MISC CHANGES.<<<Full plan check. Changes to approved set of plans commercial building. Changes under delta 4. Changing feeder size and modifying electrical equipment labeled under delta 4. Also modifying emergency lighting, t-24.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67721	19041-20000-01446	5101 N CALATRANA DR	91364	3	171B105  1127	2168015049	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.16127	-118.60255	Installation of (1) Tesla battery back up (ESS) 5 kWh to an existing PV system.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67722	17041-10002-24366	8211 N REMMET AVE	91304	3	189B105    35	2110019022	[Q]CM-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.05	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.21802	-118.60044	REVISION TO APPROVED SET CLOUDED AND NOTED AS DELTA R2. THIS IS PLAN CHECK ONLY, NO ADDITIONAL PERMIT IS NEEDED  <<PC FOR COMMMERCIA PV SYSTEM USING 14KW INVERTER AND 32 MODULES.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67723	17041-30000-39288	1875 S CENTURY PARK EAST	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.06115	-118.41457	Plan check for Power only, adding new EV loads to existing 400A meter section, with no other loads served. EV charger located on parking level 3 and 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67724	15041-20001-04534	380 WORLD WAY T 35	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM			PC Approved	07/02/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	Changes to approved set per inspectors request.  Switchbank labeling updated to reflect actual use of LED lighting as display and task lighting.  Title 24 plan check only.  Total area = 162 sq. ft.T.I. to currency exchange counter space at airport.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67725	16041-10000-02862	4530 N SHERMAN OAKS AVE	91403	5	168B145  1028	2283023008	C1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Issued	02/23/2016 12:00:00 AM	ADDRESS	34.1531	-118.46903	PC for energy to a Medical office (dental). Tenant improvement, adding new lighting and power. Total sq ft = 575	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67726	11041-10000-21472	1513 S GRAND AVE # 310	90015	9	124-5A207 143	5134015027	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	02/14/2012 12:00:00 AM	ADDRESS	34.03622	-118.26632	Health Care Facility, Art. 517.TENANT IMPROVEMENT TO EXISTING BUILDING; NEW PARTITIONS, DOORS, MILLWORK CEILING; LIGHTS AND ELECTRICAL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67727	13041-10000-16329	501 WORLD WAY	90045	11	090B165   128	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	33.94297	-118.40516	PLAN CHECK FOR TITLE 24 PART 6 ENERGY. SINGLE TOWER AT LAX. SCOPE OF WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67728	15041-10000-06089	722 S BIXEL ST 1-316	90017	1	130-5A207 630	5143004011	CW	Central	Westlake	Downtown Los Angeles		2093.00	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.05004	-118.26445	PV2 225KW roof-mounted system with (1) Solectria Smartgrid-225, (10) combiner boxes,  and (828) Inotech Solar-260  modules interconnecting  the main building panel. zero permit fees due to senate bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67729	13041-20000-20012	22612 W COVELLO ST	91307	12	186B097   373	2022010011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	34.20724	-118.62001	pv1 single family dwelling. total system size 5.2 kw using transformerless inverter. nonstandard plan. total of 16 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67730	14041-20000-17922	314 N BARRINGTON AVE	90049	11	135B141   121	4429023025	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.06895	-118.47258	New service distribution board for SFD, 600A rated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67731	15041-10001-16729	5356 S VICTORIA AVE	90043	9	099B205   912	6030032021	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			PC Approved	12/22/2015 12:00:00 AM	ADDRESS	33.99338	-118.33202	12-22-15Changes to an Approved set of plans, changes include the roof layout. *** inspecction fees are $0 due to senate bill 1222(((PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.  (21) KYOCERA 260 MODULES(1) ABB PV1 5.0 INVERTER)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67732	19041-10000-34016	5700 W WILSHIRE BLVD #540, 550	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.06218	-118.35303	PLAN CHECK FOR TITLE 24 ONLY FOR - TENANT IMPROVEMENT TO EXISTING OFFICE UNIT #540,550 - SCOPE IS RELOCATION OF EXISTING FIXTURES DUE TO LAYOUT CHANGE WITH PHOTOMETRICS REPRESENTING PATH OF EGRESS CONNECTED TO EXISTING EMERGENCY SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67733	19041-30000-43066	350 S GRAND AVE #100A	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.05173	-118.2522	T-24, PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO (E) SPACE. TOTAL SQ. FT. 2925.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67734	19041-10000-44901	321-323 S BURNSIDE AVE	90036	4	135B177    42	5509003009	RD1.5-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	08/14/2020 12:00:00 AM	ADDRESS	34.06986	-118.35579	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES INSTALLING NEW LIGHTS AND CIRCUITS. TOTAL AFECTED AREA IS: 3,151 SFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67735	12041-10000-01445	25820 S VERMONT AVE	90710	15	033B197     9	7412010903	OS-1XL-O	Harbor	Wilmington - Harbor City	Harbor City, Wilmington		9800.15	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	03/11/2014 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	33.78902	-118.29358	Plan check power for new pumps, oxygen generator, and phosphorous removal system for lake water treatment. Site located in methane zone. Ken Malloy Harbor Park	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67736	15041-20000-27372	17452 W ROSCOE BLVD	91325	12	192B129   350	2201010012	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.22076	-118.51383	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (27) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67737	17041-10000-21048	13100 W PAXTON ST	91331	7	213B161   658	2533002024	C2-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.27933	-118.41808	PC for title -24  only. Remove HID fixtures and replace with new LED fixtures. total affected area 12700 sq.ft (outdoor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67738	19041-10000-34038	15401 W COBALT ST	91342	7	225B145   352	2501005009	[Q]MR1-1, [Q]P-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Issued	01/23/2020 12:00:00 AM	ADDRESS	34.30914	-118.46789	T-24 PLAN CHECK FOR A TI TO BATHROOM AREAS IN AN OFFICE SPACE. SCOPE INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 361 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67739	19041-20000-03068	24227 S ROSCOE BLVD	91304	12	192B089   180	2017038012	RE11-1-H	South Valley	Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.21965	-118.65504	pv1install roof mounted PV System sized 2.835KW with 9 PV Modules, 1 inverter(3KW) and interconnected with 400A msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67740	13041-10000-10556	2030 N CUMMINGS DR	90027	4	151-5A195 179	5589009019	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Expired	05/20/2015 12:00:00 AM	ADDRESS	34.10803	-118.30192	PV1 ONE STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 8.82 KW STANDARD PLAN. [INVERTER: SUNNY BOY 7000-US] [SOLAR MODULE: TRINA SOLAR TSM-PC/PA05].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67741	14041-10000-14256	7226 N DEERING AVE	91303	3	183B105    29	2112026006	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.20192	-118.59652	Remove HID light fixtures and replace with new flourescent	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67742	18041-10001-19288	4570 W COLORADO BLVD	90039	13	162B205   118	5593018015	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM			PC Approved	02/26/2019 12:00:00 AM	ADDRESS	34.14078	-118.27277	Change to approved set by reducing the size of the scope to portion of the first floor only. Permit fee is under master application.((((PC FOR TI WORK IN EXISTING  WAREHOUSE BLDG ON THE FIRST AND SECOND FLOOR FOR TITLE 24 ENRGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL EFFECTED AREA 2327SQ.FT))))B#18016-10000-16272	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67743	16041-20001-05583	2137 S DUXBURY CIR	90034	5	126B165   147	4309009022	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.04401	-118.39622	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL( HOUSE)  AND MICROINVERTER ( GARAGE)  SYSTEM. SYSTEM SIZE: 16.8 KW2  FRONIUS 6.0 CENTRAL INVERTER4 ENPHASE M250 MICROINVERTER ( GARAGE - 4 MODULES)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67744	16041-20000-24814	14190 W AZTEC ST	91342	7	219B153   224	2508025040	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Expired	08/22/2018 12:00:00 AM	ADDRESS	34.2983	-118.44203	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67745	16041-10000-15023	5235 N KESTER AVE	91411	4	172-5A149 306	2250021***	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	Commercial			04/28/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	ADDRESS	34.16587	-118.45774	PC FOR AN EXISTING FIRE ALARM SYSTEM. SCOPE INCLUDES REPLACING THE FIRE ALARM PANEL, 8 PULLSTATIONS. ALSO ADDING ONE NEW HEAT DETECTOR AND ONE NEW PULLSTATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67746	16041-30000-29109	601 S FIGUEROA ST #4400	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check Title 24 only in existing space office T.I. Total area: 3,275 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67747	14041-10001-12644	2251 N ROSCOMARE ROAD	90077	5	153B145   139	4377011020	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.11408	-118.46383	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL  9 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL, TRANSFORMERLESS INVERTER AND WITH OPTIMIZERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67748	17041-10000-28079	17730 W SIDWELL ST	91344	12	219B129   661	2601071017	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.30069	-118.52035	PC for new 7.6KW rooftop PV system with 32 modules, 32 optimizers and one solaredge SE7600A central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67749	17041-10000-15965	10250 W CONSTELLATION BLVD STE 700	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 only in existing high rise building T.I. office space. Total area: 12,620 sq ft.B#17041-10000-12411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67750	13041-20000-19990	20467 W SHERMAN WAY	91306	3	183B109    59	2114017015	P-1VL, [Q]C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	Commercial			07/26/2013 12:00:00 AM	07/29/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.20128	-118.57939	"Change to lighting in an existing massage parlor.  Load is less than 400 amps.  PLAN CHECK ONLY for T-24.  Permit fees are under INSPECTION.      ""COMPLY WITH DEPARTMENT ORDER effective date03/29/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67751	12041-10000-22621	333 S ALAMEDA ST	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			PC Approved	09/21/2012 12:00:00 AM	ADDRESS	34.04448	-118.23824	TENANT IMPROVEMENT IN AN EXISTING RESTAURANT IN SPACE # 301PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67752	13041-10000-15716	8847 W VENICE BLVD	90034	10	123B169  1238	4312008045	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.03063	-118.38653	PLAN CHECK FOR FIRE ALARM IN A COMMERCIAL LOCATION. 18 DEVICES AND 1 FIRE ALARM CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67753	16041-10001-35601	23559 W MARIANO ST	91367	3	174B093   554	2044009012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.16884	-118.64058	Expedited fees. PV1 roof mounted solar system installation to a singel family home. Installing 2 central inverters rated at 7.0 kw each for a total system size of 14 KW. 50 new solar modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67754	11041-20000-22513	1701 N MANDEVILLE CANYON ROAD	90049	11	135B137   476	4426003013	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2011 12:00:00 AM	01/10/2012 12:00:00 AM		Permit Finaled	01/23/2012 12:00:00 AM	ADDRESS	34.0645	-118.49336	New 9.68 KW DC roof mounted solar system for a single family residence.  Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67755	11041-10000-20410	847 S ALVARADO ST	90057	1	130-5A203  17	5141021007	C2-1	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Apartment			09/26/2011 12:00:00 AM	01/25/2012 12:00:00 AM		Permit Expired	06/01/2022 12:00:00 AM	ADDRESS	34.05366	-118.27878	New 7-unit addition to an existing 98-unit apartment complex.  New 1200A service.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67756	18041-10000-37152	5932 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	33.94435	-118.38715	Energy plan check for an outdoor lighting mounted on the trailer with a total area of 4750-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67757	14041-10000-28078	11400 W OLYMPIC BLVD	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM			PC Approved	10/10/2014 12:00:00 AM	ADDRESS	34.03666	-118.44346	Title 24 plan check only.  Total area = 1,080 sq. ft.T.I. for new lighting in an existing office highrise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67758	17041-20000-11549	8840 N CORBIN AVE	91324	12	195B117    64	2783025092	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			Reviewed by Supervisor	04/26/2017 12:00:00 AM	ADDRESS	34.23069	-118.56211	ti to an existing comercial building (target).  adding new lighitng new controls to new panels.  newly conected load > 400 amps.  plan check for power and energy.  total square footage 91869.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67759	14041-10000-14322	6250 W HOLLYWOOD BLVD Suite D	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.10133	-118.32547	T-24 lighting plan check only for small bakery.  CHANGE OF USE FROM RETAIL TO SMALL BAKERY.  NO SEATING OR EATING IN PREMISES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67760	16041-20001-05058	6201 N COLDWATER CANYON AVE	91606	2	177B161   414	2331011111	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM			PC Approved	03/01/2016 12:00:00 AM	ADDRESS	34.18306	-118.41396	EXPEDITED PER APPLICANT REQUEST(((((PLAN CHECK SUBMITTAL - ROOF MOUNTED SOLAR PV SYSTEM FOR AN EXISTING APARTMENT SYSTEM SIZE 40 KW AND 160 PV MODULES (CS6P255P) AND 5 INVERTERS (SB70000US-12))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67761	18041-20000-44746	21300 W VICTORY BLVD Suite 750	91367	3	180B105    55	2149001031	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check for Title 24 only. Project site is an existing suite in a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,641 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67762	15041-10000-10141	12746 W JEFFERSON BLVD 1160	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			04/06/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	05/27/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Methane gas detection system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67763	19041-10000-22546	11623 N GLENOAKS BLVD	91331	7	213B157   420	2524023003	[Q]C2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Permit Finaled	08/27/2019 12:00:00 AM	ADDRESS	34.28087	-118.41962	T-24, ENERGY PLAN CHECK FOR DMV OFFICE T. I. SCOPE INLCUDES NEW RETROFIT LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 18,616-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67764	10041-10000-21413	5076 W SUNSET BLVD	90027	13	147A195   545	5543026034	C2-1D	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	11/18/2010 12:00:00 AM	ADDRESS	34.09789	-118.3003	AT A 7-11 BUILDING, 1 FOR 1 REPLACEMENT OF EXTERIOR LUMINAIRESON THE BUILDING AND FOR THE PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67765	14041-20000-03082	19322 W COHASSET ST	91335	3	186B117  1064	2116016123	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.20639	-118.55429	PV1 SINGLE FAMILY DWELLING. USING ENPHASE M215. USING STANDARD PLAN. TOTAL SYSTEM SIZE 3KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67766	19041-10000-27484	1005 S HOOPER AVE	90021	14	121-5A213  50	5130005014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.02845	-118.2419	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67767	19041-10000-43273	6132 N CAPISTRANO AVE	91367	3	177B101    89	2039029024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.18192	-118.61699	NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 225 AMPS WITH 30 MODULES (SN310M-10/15 ALL BLK), 30 MICROINVERTERS(IQ7-60-2-US), AND 1 COMBINER BOX (IQ7-60-2-US)SYSTEM SIZE: 9.3 KW DC; 7.5 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67768	12041-10000-27570	300 S GRAND AVE 4th floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	12/06/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	TI in an existing office. EPC is for T24 and emergency lighting. (4th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67769	16041-20000-01538	5850 N SEPULVEDA BLVD	91411	4	174B145    43	2243018028	C1.5-1VL-RIO, P-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	03/20/2017 12:00:00 AM		Issued	03/20/2017 12:00:00 AM	ADDRESS	34.17721	-118.46589	TI to existing commercial building (PETCO). Plan check for energy only. Adding new lighting including emergency. Total sqft. 15,005.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67770	19041-20000-40817	211 S CENTRAL AVE UNIT#211-213	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.04741	-118.23966	Tenant improvement to retail space, new lighting and associated load. Total area: 2311 sq ftB#19016-30001-19728	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67771	12041-20000-23783	20332 W VIA SANSOVINO	91326	12	219B113   280	2701061020	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.29651	-118.57665	Single famil dwelling PV solar installation. 2 tranformerless inverters (Power-One). System size is 11.025 kW DC, 9.41 kW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67772	15041-10000-30005	2415 W AVENUE 30	90065	1	150B213   548	5457010028	R3-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	11/20/2015 12:00:00 AM		Permit Expired	12/25/2017 12:00:00 AM	ADDRESS	34.1068	-118.2385	PC FOR ENERGY ONLY, T-24 TO AN (E)  BUILDING. TI TO A DAY CARE FACILITY, SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1263	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67773	12041-10000-17703	10930 N GERALD AVE	91344	12	210B137   780	2683013014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2012 12:00:00 AM	08/27/2012 12:00:00 AM		Permit Finaled	09/07/2012 12:00:00 AM	ADDRESS	34.26924	-118.49437	New 2.16kw rooftop mounted PV system for an existing single family residence.  System uses Enphase M215 Micro-Inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67774	18041-20000-02670	751 S BURLINGAME AVE	90049	11	126B141   668	4264007052	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			01/24/2018 12:00:00 AM	03/20/2019 12:00:00 AM		Issued	03/20/2019 12:00:00 AM	ADDRESS	34.04291	-118.48237	NEW 6 UNIT/4 STORY (TYPE 111A) APT. OVER TYPE IA SUBT. PARKING GARAGE. PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67775	18041-10001-13358	100 S GRAND AVE	90012	14	132A211    45	5149010949	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Closed	02/08/2022 12:00:00 AM	ADDRESS	34.05536	-118.24876	CHANGE TO AN APPROVED SET , CHANGE INCLUDE ADDING 2 PANEL , (300A) AND (200) TO FEED 45KVA TRANSFORMERS PER EACH.ORIGINAL SCOPE: 277/480V, 3 PH, 5,000 AMP TEMPORARY POWER FOR CONSTRUCTION OF 2 HIGHRISE BUILDINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67776	13041-10002-18375	236 S LOS ANGELES ST	90012	14	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM			PC Approved	10/17/2014 12:00:00 AM	ADDRESS	34.04922	-118.24386	Additional sensors are added to approved set. all sensor are compatible with methane detection system.(((New methane gas detection system, Level 5.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67777	17041-20000-25396	21347 W VENTURA BLVD	91364	3	171B105    22	2167001018	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.16798	-118.5971	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR WHOLE FOODS. building permit #   17014-10000-02197	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67778	16041-10000-44013	6103 S CRENSHAW BLVD	90043	8	105B185   568	4006004031	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	33.98446	-118.33105	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 55575.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67779	16041-20001-30908	1902 E MARENGO ST STE109-110	90033	14	132A223    33	5201016003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	11/28/2016 12:00:00 AM		Issued	11/28/2016 12:00:00 AM	ADDRESS	34.05756	-118.21009	Plan check for power for first-time tenant per inspector's correction notice.  Additional permit fees to cover additional items listed on plans.  (((TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY SUITE 109 AND 110.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67780	17041-30000-22686	11609 W WASHINGTON PL	90066	11	114B157  1421	4214014002	C1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM			PC Approved	07/06/2017 12:00:00 AM	ADDRESS	34.00485	-118.42087	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,174 sq. ft.Note: Building permit has been issued under 17016-30000-08010.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67781	14041-10000-06164	2881 W 15TH ST	90006	10	129B193  1524	5074004021	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			PC Info Complete	03/18/2014 12:00:00 AM	ADDRESS	34.04549	-118.30557	PV1,INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000-US-ZB-U(13) CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67782	12041-10000-22239	11350 W VICTORIA AVE	90066	11	114B157    91	4234003040	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.01234	-118.42223	PV1 INSTALLATION ROOF MOUNTED 4.16KW PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67783	18041-10001-48482	4615 N KESTER AVE	91403	4	168A149   140	2264020028	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			12/04/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.15437	-118.45765	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES REVISIONS TO LIGHTING LAYOUT, REMOVAL OF EQUIPMENT, AND UPDATED PHOTOMETRICS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. ORGINAL SCOPE OF WORK [[NEW CONSTRUCTION OF A 4-STORY (11)-UNIT BUILDING WITH SUBTERRANEAN LEVEL PARKING AND ROOF DECK. SCOPE INCLUDES FULL PC OF PWR AND LTG. 1000A ,120/208V, 3PH. B# : 18010-10000-04216AUTOMATIC SPRINKLER SYSTEM (NFPA 13). BASEMENT CONSISTS OF TYPE 1-A CONSTRUCTION, GROUPS S-2. FLOOR 1 CONSISTS OF TYPE 1-A CONSTRUCTION, GROUPS S-2, R-2. FLOORS 2, 3, 4 AND ROOF DECK CONSISTS OF TYPE V-A CONSTRUCTION, GROUP R-2. with 20% density bonus, 5 % very low income unit. pwer 12.22A.25]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67784	14041-10000-09761	1075 N VILLA GROVE DR	90272	11	129B129   356	4409006014	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Expired	05/16/2016 12:00:00 AM	ADDRESS	34.04995	-118.51364	PV1, Install 6 kw DC roof-mounted solar array on a one-story home, interconnect with main service panel.(1) Transformerless Inverter: SOLAREDGE SE6000A-US-ZB-U(24) Modules: CANADIAN SOLAR CS6P-250X	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67785	17041-30000-25214	16836 W SHERMAN WAY	91406	6	183B133   124	2225018012	R3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Apartment			07/25/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.20089	-118.50004	Plan check for a fire alarm system for a 4-story, 18-unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, (74) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67786	19041-20000-52449	11259 W OLYMPIC BLVD	90064	11	126B153   958	4260001028	[Q]C2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	11/19/2020 12:00:00 AM		Permit Finaled	08/02/2021 12:00:00 AM	ADDRESS	34.03875	-118.44075	Plan check for PV roof mounted system, PV system size: 120.08KW DC, 100KW AC with 395 PV Modules and 1 inverter(100KW) Supply  side connection. Permit Fess $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67787	18041-10000-01011	5700 W 96TH ST	90045	11	093B169   169	4125024024	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	33.94928	-118.38132	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 34150 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67788	12041-20000-19417	6551 N VAN NUYS BLVD	91411	6	180B149   514	2236011023	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM			PC Approved	08/17/2012 12:00:00 AM	PIN	34.18983444	-118.44926241	Plan check for energy and emergency lighting. Bank of America. 1137 sqft. New restrooms, breakroom and relocated NER (data) room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67789	14041-10000-28102	5455 W WILSHIRE BLVD Suite 2000	90036	4	135B181   903	5508010025	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.06246	-118.34749	Plan check for power and energy.  T.I. to highrise medical office (doctor's office, psych rooms, physical therapy).  Lighting and recepticles.  Total area = 3,350 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67790	19041-20000-40308	1539 N MURRAY DR	90026	13	144A203   198	5425002007	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.08898	-118.27418	INSTALL (2) NEW TESLA STORAGE BATTERIES ON EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67791	14041-20000-27972	7816 N LAURELGROVE AVE	91605	2	189B165   814	2309014022	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Refund in Progress	08/17/2015 12:00:00 AM	ADDRESS	34.21255	-118.40075	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(14) SUNPOWER 327W MODULES(1) POWER ONE 4.2KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67792	10041-20000-23015	1888 S CENTURY PARK EAS #1850	90067	5	132B161    14	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	PIN	34.06139499	-118.41373129	Plan check T24 Energy (general/emergency) lighting for office TI, suite #1850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67793	17041-20001-18606	1331-1335 E 6TH ST	90021	14	126A215   289	5164008005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.03833	-118.23479	06/14/2018 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the lighting floor plans and reflected onto the Title 24 forms. There has been the addiiton of a new panel (no loads).*****Previous Work Description*****Plan check for energy only. Change of use from warehouse space to restuarant (pizzeria). New lighting (incl. emergency). New outdoor lighting under new entryway-canopy. 1,972sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67794	16041-10000-32628	1600 W SAN FERNANDO ROAD	90065	1	147A217   178	5442005010	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.09791	-118.23331	Plan check for Title 24 only remove outdoor HID lighting fixture and replace with new LED lighting fixtures. Total area: 35,650 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67795	15041-20000-27187	1636 W 8TH ST	90017	1	130-5A205 112	5142017021	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.05263	-118.27317	PC FOR REMOVAL OF SINGLE PHASE SERVICE AND RELOCATE LOADS ONTO EXISTING 3 PHASE SERVICE. ADDITION OF SUBPANEL AND TRANSFROMER TO PROVIDE SINGLE PHASE LOADS. THIS IS TO MAKE ROOM FOR FUTURE PV CONNECTION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67796	15041-20000-29116	200 WORLD WAY #250-C	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan check Title 24 only for kiosk Internaltional Currency Exchange. Total area: 147sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67797	15041-10001-03679	10940 W WILSHIRE BLVD 11th floor	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM			PC Approved	05/08/2015 12:00:00 AM	ADDRESS	34.05822	-118.4452	((((5/8/2015))))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 4 ON THE FLOOR PLANS.  CHANGES INCLUDE LIGHTING FIXTURES AND ENERGY CALCS.Plan check for Title 24 only. Project site is the 11th floor of a high-rise building. Project scope is a tenant improvement. Total lighting area = 10,256 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67798	16041-20000-02147	14545 W VENTURA BLVD	91403	4	166-5A151  95	2265010004	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.15135	-118.45029	TI to existing commercial building. Plan check for energy only. Adding new lighting (incl. emergency). Total sqft. 682.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67799	14041-10000-27478	1122 W 20TH ST	90731	15	012B193  1023	7460027022	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2972.02	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/27/2014 12:00:00 AM	ADDRESS	33.72622	-118.30182	PV1, INSTALL 11.22 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(44) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: ABB PVI-4.2-OUTD-S-US-Z-A & PVI-3.6-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67800	15041-20000-31708	555 W 5TH ST FIRST FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI TO CORRIDOR ON FIRST FLOOR. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67801	13041-10000-26659	2500 S WESTERN AVE	90018	8	123B193   477	5058015005	[T][Q]C2-2D	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.03373	-118.30879	INSTALL NEW FIRE ALARM SYSTEM FOR SCLARC OFFICE BUILDING. 6 FIRE ALARM PANELS , 171 FIRE ALARM DEVICES. 6 STORY BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67802	10041-10000-12045	8605 W PICO BLVD	90035	5	132B173  1217	4332023048	C4-1-O	Central	Wilshire	South Robertson		2164.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	ADDRESS	34.05401	-118.37879	Ti in an existing restaurant, Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67803	17041-10001-38335	2079 N MOUNT OLYMPUS DR	90046	4	151-5A175  72	5569026003	RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Closed	03/14/2022 12:00:00 AM	ADDRESS	34.10978	-118.3665	SUPP. TO AN ONLINE PERMIT UNDER 17041-90000-38335.  TO REFLECT FIELD INSTALLATION. ADDITIONAL PERMIT FEES ARE DUE FOR LOAD CIRCUIT AND ADDITIONAL CIRCUIT. ROOF MOUNTED PV ON SFD WITH 23 AC MODULES AND A LOAD CENTER. TOTAL SYSTEM SIZE 7.36KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67804	16041-20005-44615	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM			PC Approved	10/21/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	Changes to approved set - delta 20 revisions only on sheets E100L and E111L.  Removal of landscape lighting in select locations, removal of (1) exit sign from basement lighting plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67805	18041-10000-18463	4501 W COLORADO BLVD	90039	13	162B205    19	5593012040	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.14246	-118.2705	Plan check for T24 only, install lighing on two storage room. Total area: 70.5 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67806	16041-10002-42206	838 W 30TH ST	90731	15	009B197  1349	7469010009	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	33.71751	-118.29665	03-30-2017 Changes to an approved set of plans. Changes include revise plan to reflect field installation. Changes has been coude.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67807	12041-10000-00486	16026 W RAYEN ST	91343	12	195B141   365	2672019019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2012 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	03/13/2012 12:00:00 AM	ADDRESS	34.23188	-118.48159	Roof mounted PV system, 13.4 KW, SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67808	09041-10021-24270	380 W WORLD WAY NORTH-CONCOURSE	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/23/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	CPlan review for RFI FILES for the Bradley West Gates and West Core	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67809	15041-10000-12165	825 W COLORADO BLVD 3rd floor	90041	14	163-5A231 142	5709002012	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Issued	06/16/2015 12:00:00 AM	ADDRESS	34.1404	-118.18419	Energy plan check for an office T.I located at 3rd floor  (Kaiser Foudation Health Plan, Inc) of a commercial building; scope includes replacing exsiting panels with new panels, and new installation of new UPS for the Telecom room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67810	19041-20000-32929	3240 W WILSHIRE BLVD	90010	10	132B197    65	5094008044	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			08/21/2019 12:00:00 AM			PC Info Complete	10/22/2019 12:00:00 AM	ADDRESS	34.06162	-118.2924	New distribution, power, and lighting using (E) 3000A 480Y/277V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67811	11041-10000-04884	1630 N MAGNETIC TER	90069	5	147B169   377	5561016026	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2011 12:00:00 AM	06/24/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	34.10005	-118.39107	NEW 13.8 KW PV SYSTEM ON A SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67812	17041-20002-03721	13720 W VANOWEN ST	91405	2	180B157    55	2238010030	C2-1, R1-1, [Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM			PC Approved	05/24/2017 12:00:00 AM	ADDRESS	34.19378	-118.43188	5.24.2017 - Plan check for modification to approved set. Adding 16 outdoor lights, update floor plan, fixture schedule, and T24 compliance forms to reflect change. ======plan check for energy indoor/outdoor only.  total square footage 3712.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67813	13041-10000-31515	13031 W JEFFERSON BLVD BUTLER BLD-G	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	05/01/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK HAS BEEN CLOUDED. INSTALLING FEW 6 PANELS AND 3 MOTORS UNDER EXISTING 3000 A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67814	19041-10000-37394	1120 E L ST	90744	15	033B209   343	7425014049	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	33.7873	-118.24889	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67815	19041-10000-48290	10535 W MOORPARK ST	91602	4	165B177   311	2424002007	RD1.5-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			11/21/2019 12:00:00 AM	08/19/2020 12:00:00 AM		Permit Finaled	12/03/2020 12:00:00 AM	ADDRESS	34.15052	-118.36066	NEW FIRE ALARM CONSIST OF 1 FACP, ANNUNCIATOR, COMMUNICATOR AND 60 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67816	16041-20000-18711	9809 N SHOUP AVE	91311	12	201B101   219	2727004012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	34.24857	-118.61504	Plan check for PV roof mounted system. System size: 8.96 kW and 32 modules and 32 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67817	13041-10000-01075	1241 S SOTO ST	90023	14	121-5A221 147	5170017030	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM			PC Approved	01/15/2013 12:00:00 AM	ADDRESS	34.02743	-118.21975	emergency lighting and exit signs for a small corridor for 2 areas of a low rise commercial building. total area covered for energy is 107 sq ft. awaiting cra approval	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67818	14041-20000-01334	16640 W BRYANT ST	91343	12	195B137   900	2689021013	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.2274	-118.49544	PV1 TRANSFORMERLESS USING OPTIMIZERS. TOTAL SYSTEM SIZE 6.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67819	19041-20000-41844	8555 W COLGATE AVE 1-8	90048	5	138B173  1136	4334016030	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			10/15/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Closed	11/10/2020 12:00:00 AM	ADDRESS	34.07093	-118.37799	PLAN CHECK FOR NEW FIRE ALARM SYSTEM IN NEW 5-STORY APARTMENT BUILDING. SCOPE OF WORK CONSISTS OF (1) FIRE ALARM PANEL AND (54) FIRE ALARM DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67820	18041-10000-12963	5156 S BRYNHURST AVE	90043	8	108B185   121	5013007015	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	33.99513	-118.33314	PV1. ADDING A NEW STRING OF MODULES FOR AN EXISTING PV SYSTEM. SCOPE INCLUDES ADDING 7 MODULES. ADDING 1.96KWdc TO AN EXISTING 3.06KWdc PV SYSTEM. TOTAL DC WATTAGE FROM EXISTING AND NEW IS 5.02KWdc.  THE AC SYSTEM SIZE REMAINS 3.6KWac. (7)MODULES-Q-CELLS # Q. PLUS-G4.1/SC-280	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67821	14041-10000-09278	111 N HOPE ST	90012	14	133-5A211 168	5161003910	PF-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Issued	04/08/2014 12:00:00 AM	ADDRESS	34.05807	-118.24862	Demolishing the old bus extension, supplying medium voltage power to two chillers, and reconnecting the new switchboard to the main section no added power.  Phase two is for the future no load added; medium voltage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67822	13041-20000-36182	9761 N BABBITT AVE	91325	12	201B133   303	2692023010	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.2482	-118.51046	pv1 single family dwelling. total system size 8kw ac using transformed inverter 3 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67823	15041-20000-41730	10309 W SANTA MONICA BLVD	90024	5	132B157   365	4327017017	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	PIN	34.05943838	-118.42195052	Conversion of (E) parking area into proposed medical office shell with elevator lobby.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67824	19041-20002-33562	7930 W DAY ST	91040	7	204B193   970	2559022007	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.25455	-118.30592	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414.SUPPLEMENTAL PLAN CHECK ONLY, CHANGE TO APPROVED SET, CHANGE TO SINGLE LINE DIAGRAM TO CHANGE MAIN PANEL TO SUB PANEL AND ADD A COMMERCIAL SAFETY METER SOCKET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67825	16041-10001-19529	3334 S CABRILLO BLVD	90066	11	114B149   133	4247018017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2016 12:00:00 AM			PC Approved	06/11/2016 12:00:00 AM	ADDRESS	34.01139	-118.44623	New 3kw solar system being added to an existing 2kw system. Total system size is 5KW. (14) modules (1) solar edge Inverter.EXPEDITED PER CUSTOMER REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67826	15041-20000-30812	6301 N OWENSMOUTH AVE 11th Floor	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.18467	-118.60176	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 20,558 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67827	18041-10000-04370	5327 S 6TH AVE	90043	8	108B189   422	5006024019	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	33.99425	-118.32376	PV1. NEW SOLAR SYSTEM FOR AN EXISTING DUPLEX BUILDING. TOTAL SYSTEM SIZE IS 2.44KWdc / 3.8kWac. Installing 8 modules with optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67828	18041-30000-45074	11800 N FOOTHILL BLVD	91040	7	210B165   540	2528002901	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District, Pacoima	YES	9800.21	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	07/01/2019 12:00:00 AM		Issued	07/01/2019 12:00:00 AM	ADDRESS	34.273	-118.39313	NOTE: PERMIT FEES ARE $0 DUE TO AB 1414.PV2. NEW ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTERS. (7) SOLAREDGE SE33.3KUS INVERTERS AND (628) PV MODULES. TOTAL SYSTEM SIZE IS 251.2KWdc / 233.1KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67829	13041-20000-07540	821 N WILCOX AVE	90038	4	141B185   161	5533026057	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			03/22/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	34.08593	-118.33113	solar apartment 31.5 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67830	10041-10000-09331	999 N NORTH BROADWAY	90012	1	136-5A215 186	5414007015	C2-2	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	03/03/2011 12:00:00 AM	ADDRESS	34.06666	-118.23614	TI IN  MOTEL OFFICE.  PLAN CHECK FOR T24 AND ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67831	16041-20001-12444	13803 W FOOTHILL BLVD 2nd Floor	91342	7	225B153   381	2509002037	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Commercial			06/15/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.31046	-118.43385	06-15-16 Changes to an approved set of plans, Changes include delta 2 change from #10 conductor size to #12 and feeder size and breaker. (((((Plan check for power and energy. Project site is the 2nd floor of an existing commercial building. Project scope is a change of use from medical office to office/tenant improvement. Total lighting area = 11,000 sq. ft. Note: Building application has been generated under 16016-20000-08201))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67832	18041-20001-45112	19843 W GILMORE ST	91367	3	180B113   723	2134027008	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2019 12:00:00 AM			PC Approved	02/04/2019 12:00:00 AM	ADDRESS	34.1876	-118.56584	02/04/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. Changes have been made to the interconnection configuration.*****Original Work Description*****Plan check for PV roof mounted system install with existing PV system, Addition PV system size: 11.88kW with 33 AC Modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67833	16041-10000-37831	19191 S VERMONT AVE 6th Flr	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR T24, ENERGY ONLY FOR SPEC SUITES ON 6TH FLOOR. OFFICE TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67834	10041-10000-14469	6740 W HOLLYWOOD BLVD	90028	13	148-5A185 149	5547012016	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM	12/23/2010 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	34.10139	-118.33752	TI IN AN EXISTING COMMERCIAL AREA. NEW 600 AMP SERVICE, PANELS & CIRCUITS. PLAN CHECK IS FOR POWER AND ENERGY.  FIRE LIFE SAFEY PLANS SUBMITTED UNDER PCIS # 10041-10000-14472	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67835	10041-20000-23032	20355 W SORRENTO LANE Building-13	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Apartment			11/18/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.27828	-118.57751	Plan check for new 3-story, 36 unit Apartment Building (Type A) Building 13. Modification to seperate fire alarm system filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67836	13041-10000-01602	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM			Reviewed by Supervisor	01/29/2013 12:00:00 AM	ADDRESS	33.78054	-118.23195	INSTALLATION OF NEW 208V , 3P, 2HP MOTOR OPERATED VALVE AND CONTROL PANEL.WORK TO BE DONE IN HAZARDOUS AREA. OIL REFINERY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67837	08041-20001-21050	11055 W BURBANK BLVD	91601	2	174B173  1381	2337029028	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			04/07/2010 12:00:00 AM			PC Approved	04/07/2010 12:00:00 AM	ADDRESS	34.17235	-118.37235	previously approved plan changing interior lighting setup. the plan check is title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67838	19041-20000-00980	9765 N ABREGO CT LOT 8	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.24779	-118.45069	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67839	17041-10000-09012	10250 W SANTA MONICA BLVD #1587	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"FULL PC FOR FIRST TIME TI ""CURRENCY EXCHANGE INTERNATIONAL""  IN WESTFIELD CENTURY CITY. SUITE 1587"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67840	14041-20000-02998	17825 W DEVONSHIRE ST	91325	12	204B129   154	2733001012	(T)(Q)RAS3-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			02/03/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.25768	-118.52255	NEW 3 STORY TYPE V-A 24 UNIT APT OVER TYPE I-A  BASEMENT GARAGE.  INSTALL NEW 1200A SERVICE, MAIN PANEL, SUBPANELS.  AND BRANCH CIRCUITS, AND LIGHTING.  PLAN CHECK FOR POWER AND ENERGY.  NOTE: T-24 CAL. IS REQUIRED FOR GARAGE AND COMMON AREAS.  ADDITIONAL PLAN CHECK FEE IS REQUIRED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67841	18041-10000-10895	15455 W CHATSWORTH ST	91345	7	207B145   260	2649001006	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.26472	-118.46938	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67842	16041-20000-38584	10250 W CONSTELLATION BLVD Suite 3050	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for energy only. TI to office suite #3050 in high rise office building. New lighting (incl. emergency) and receptacles. 8,412sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67843	18041-20001-03833	1651 S VIRGINIA ROAD	90019	10	126B185   203	5071008053	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM			PC Approved	02/13/2018 12:00:00 AM	ADDRESS	34.04437	-118.33274	Expedite fee.PV1.  Install 6.65 kW DC roof mounted PV system with 7.6 kW-rated string inverter with battery back-up energy storage system.  (19) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67844	12041-10000-01004	19901 W NORDHOFF ST Bldg 12	91324	12	195B113    15	2782037034	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Approved	01/31/2012 12:00:00 AM	ADDRESS	34.23201	-118.56708	New vault for pharmaceuticals, lighting changes, and new receptacles.  PLAN CHECK ONLY for Energy with Emergency lighting.  (BLDG #12)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67845	19041-20000-52521	108 W 2ND ST 1-135	90012	14	130-5A213 201	5149006901	C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/21/2021 12:00:00 AM	ADDRESS	34.05097	-118.24511	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24 ONLY. TOTAL AFFECTED AREA 4595 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67846	15041-10001-32875	18653 W HORACE ST	91326	12	210B121   564	2717013031	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM			PC Approved	11/03/2015 12:00:00 AM	ADDRESS	34.2697	-118.53937	PV1 roof mounted solar panel, 11.8 kW system(40) modules: Sunpower SPR-327-NE-WHT-D(2) PVI-3.8-OUTD-S-US(1) PVI-4.2-OUTD-S-USPanel Upgrade 225A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67847	13041-10000-10543	1940 N HIGHLAND AVE	90068	4	150A185   135	5575024***	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00, 1897.02	Electrical	Electrical	Commercial			04/24/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.10597	-118.33729	REPLACE FIRE ALARM PANEL AND ANNUNCIATOR WITH A NEW FIRE ALARM PANEL (EVERYTHING IS LIKE FOR LIKE {SAME RATING}). NON HIGHRISE APARTMENT COMPLEX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67848	10041-10000-05880	380 WORLD WAY	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	05/05/2010 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	"Proposed 34.5KV DuctBank in LAWA at ""CONCOURSE CCP"".  Approx 1300'.  REF.#10042-10000-07058"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67849	18041-10000-03919	2300 W 3RD ST	90057	1	135A203   214	5154035029	C2-1	Central	Westlake	MacArthur Park	YES	2088.02	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.06402	-118.27494	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67850	16041-10000-04992	11650 W PICO BLVD	90064	11	123B153   717	4260033033	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			02/11/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.03185	-118.4448	New Fire alarm system for a new mixed-use apartment build. (1) fire alarm panel, (207) devices and (3) control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67851	15041-20000-14973	4911 N NATOMA AVE	91364	3	169-5A111  65	2166023010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.1593	-118.57914	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system (standard plan used)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67852	16041-10000-39315	6765 W SELMA AVE 1-38	90028	13	148-5A185 276	5547013017	C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	11/11/2020 12:00:00 AM	ADDRESS	34.09981	-118.33796	FULL PC FOR POWER AND ENERGY FOR A NEW BUILDING A1/A2.  A1 IS A NEW 6-STORY 96 UNIT MIXED-USED APARTMENT BLDG.  A2 IS A NEW 5-STORY 38 UNIT APARTMENT BLDG. SCOPE INCLUDES ADDING 1600A, 4000A, AND 2000A 120/208V 3 PHASE 4 WIRE SERVICES, NEW PANEL BOARDS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 30,000 SQ. FT.  B#16010-10000-01820	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67853	13041-10000-36014	12444 N MCLENNAN AVE	91344	12	219B133   460	2609025063	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.29623	-118.50108	PV1, Install 10 kW DC roof-mounted solar array for a two story house, interconnect with service panel.(2)Transformerless inverter: Solaredge SE 6000A-US and Solaredge SE 3000A-US. (40) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67854	12041-20000-03631	3216 N WRIGHTWOOD DR	91604	4	159B173   484	2380039004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2012 12:00:00 AM	06/27/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.13121	-118.3713	New roof mounted 21.42 KWdc P.V. system.  (Building integrated module)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67855	15041-20000-06541	8431 N AQUEDUCT AVE	91343	12	192B141   301	2673014037	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.22385	-118.47438	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (21) modules, and (1) inverter.Note: Standard Plan is NOT being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67856	15041-20000-34861	21215 W BURBANK BLVD 4th Floor	91367	3	174B105    88	2149019019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.17353	-118.59268	Plan check for energy only. Interior remodel to existing office on the 4th floor. New lighting (incl. emergency) and receptacles.  7,038sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67857	18041-10000-17776	16300 W VENTURA BLVD	91436	5	168B137   424	2284001062	C2-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.15674	-118.48819	FULL PC FOR POWER AND ENERGY FOR A BANK. SCOPE INCLUDES INSTALLING A NEW 600A 120/208V 3 PHASE 4 WIRE PANEL, NEW SUBPANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 6720 SQ. FT. B#18016-10000-15226	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67858	13041-10001-36301	616 W 97TH ST	90044	8	093A201   267	6054026014	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	33.94815	-118.28505	Expedited RSES plan check per applicant request.{{PV1, Install 2.75 kW DC roof-mounted solar array for a  house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3000A-US. (11) Modules: Trina Solar TSM-250PA05.18.(11) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67859	16041-10000-44677	3694 N BARHAM BLVD (BUILDING-F)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.14008	-118.34129	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67860	15041-10000-00769	1025-1035 N HIGHLAND AVE	90038	4	144B185   830	5532028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/09/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.08969	-118.33884	Power plan check.  Installation of new 500 kW standby generator in existing commercial highrise building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67861	17041-20003-09879	12601 W PIERCE ST BLDG 5, 6	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/27/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	$0 FEE DUE TO ASSEMBLY BILL 1414. CA SENATE BILL 1222. SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 2 ONLY/	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67862	14041-20000-09736	10612 W CHIQUITA ST	91602	2	162B177    53	2423030025	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Commercial			04/14/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.14402	-118.3625	Commercial retail improvements for 1,000 s.f. store in single story commercial building.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67863	18041-10000-27167	21133 W VICTORY BLVD	91303	3	180B105    50	2148031015	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.03	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.18857	-118.59382	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67864	15041-20001-08949	445 S FIGUEROA ST 19th Floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM			PC Approved	06/23/2015 12:00:00 AM	ADDRESS	34.05295	-118.25675	PC FOR CHANGES TO APPROVED SET F PLANS. CHANGE OUT 4' STRIP FIXTURES TO 2X2. ALL CHANGES CLOUDED DELTA 2 REVISION. T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67865	17041-10001-04927	1118 N MCCADDEN PL	90038	4	144B185   681	5532021029	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.09129	-118.33733	T-24  plan check for DELTA 8A only changes to an approved set. Changes to include lighting to the stairwell powered by 2 regular circuits  and 1 EM circuit. Total Affected area is 1350 sq.ft Original scope: <<FULL PC FOR POWER AND ENERGY FOR A 4-STORY RETAIL, OFFICE, CLASSROOMS, AND SENIOR CENTER BUILDING. SCOPE INCLUDES A NEW 4000A 277/480V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. >>B#16010-10000-01468	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67866	18041-10000-34689	617 W 7TH ST 200	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.04779	-118.2571	Energy plan check for an office TI located in a high rise building. Scope includes new lighting and equipment  with a total area of  5380-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67867	11041-20000-16139	14401 W SATICOY ST	91405	2	186B149     7	2215001910	PF-1XL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Info Complete	10/04/2011 12:00:00 AM	ADDRESS	34.20855	-118.4479	Plan check only. Plan check new roof mounted 106.59KW Photovoltaic system LADWP telecomm warehouse building. Permit will be on supplemental application number 11041-20001-16139	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67868	14041-20000-08979	14318 W AZTEC ST	91342	7	219B153   344	2507027009	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.2959	-118.44494	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67869	16041-20000-28688	15936 W VALLEY MEADOW PL	91436	5	162B141   270	2286024023	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.13968	-118.48062	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.8 KW.$6.05 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67870	13041-20000-09559	8719 N VARIEL AVE	91304	12	195B105   215	2779016005	(T)R3-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34, 1134.21	Electrical	Electrical	Apartment			04/15/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.22877	-118.5932	Plan check for new fire alarm system. 115 devices. 19 unit new apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67871	13041-10000-00026	5908 W MANCHESTER AVE	90045	11	096B169   563	4123014035	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			01/02/2013 12:00:00 AM	08/13/2013 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	33.95961	-118.38599	Full plan check for power and energy. New Building Single story Mcdonalds Replace lighting in dining, restrooms and crew rooms. Revise receptacles as shown on power plan.  Replace outdoor lighting on exterior of building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67872	19041-20000-29289	971 N ENCHANTED WAY	90272	11	132B121   521	4419003019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.05435	-118.54914	Plan check for PV system, PV system size: 19.8KW DC, 18.21KW AC with 60 PV modules and 60 microinverters connected to Existing 600A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67873	18041-10000-40841	441 S GLADYS AVE	90013	14	127-5A215 302	5147011018	M2-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	11/13/2018 12:00:00 AM	ADDRESS	34.04264	-118.24018	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67874	19041-20000-34445	5501 N CLEON AVE	91601	2	174B173  1245	2416001012	MR2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Info Complete	01/09/2020 12:00:00 AM	ADDRESS	34.17031	-118.36873	POWER AND ENERGY PLAN CHECK FOR NEW CONSTRUCTION. NEW 120/208V 3P 4W 800A SERVICE. NEW LIGHTS, OUTLETS, EQUIPMENT, AND T24 INCLUDED, TOTAL SQUARE FOOTAGE = 22,251 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67875	13041-10000-30879	3037 N ARROWHEAD DR	90068	4	156B185    85	5577035011	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Expired	02/08/2016 12:00:00 AM	ADDRESS	34.12419	-118.32767	PV1, Install 10 kW DC roof-mounted solar array, interconnect with service panel. negative ground inverter: Fronius IG Plus V 7.5. 40 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67876	18041-20000-35298	20704 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.29448	-118.58483	pv1install roof mounted pv system sized 5.7kw (ACM) interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67877	15041-10000-33273	9030 S LOYOLA BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	33.95663	-118.41787	New fire alarm system for a 5-Story commercial building; Scope includes (1) fire alarm panel, (1) annunciator panel,  (7) power supplies and (305) fire alarm devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67878	15041-10000-02423	1500 S ARAPAHOE ST	90006	1	127-5A201  56	5056009004	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.0452	-118.28524	Installation of new roof mounted solar PV array.  Total system size = 6.8 kWac2 Inverters with 20modules (3 strings total).  Applicant tried to pull permit online but encountered an error durring payment process.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67879	15041-10000-07101	8131 N CLYBOURN AVE	91352	2	189B177   955	2407025008	[Q]MR1-1-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.21824	-118.36494	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 3040 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67880	16041-10000-23654	189 S THE GROVE DR G5	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	11/03/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	Plan check for a methane detecting system with (1) control panel being relocated, all (9) devices shall be recalculated as a new system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67881	14041-20000-08550	4802 N VANALDEN AVE	91356	3	168B117   255	2176034015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.15756	-118.55294	PV1 16KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE5000A-US, SOLAREDGE SE5000A-US, SOLAREDGE SE3000A-US}]. [(64)modules: {Canadian Solar {CS6P 250P}}] with optimizers: [SOLAREDGE {POWERBOX 300W}]     'Expedited plan check per applicant request'(((($0 permit fee due to senate bill 1222 from 2012)))))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67882	10041-10000-12058	7260 N RADFORD AVE	91605	6	186B169   926	2317019034	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Public Safety Only			06/24/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	07/28/2010 12:00:00 AM	ADDRESS	34.20274	-118.39202	central station monitoring system for a commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67883	17041-10000-18604	1547 W 46TH ST	90062	8	111B193   398	5016008024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.002	-118.30499	Rooftop solar installation on a Single Family Dwelling, 3.8kW AC system. (9) modules and (1) inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67884	14041-20000-10881	5830 N SEPULVEDA BLVD	91411	4	174B145    68	2243018030	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM			PC Approved	04/24/2014 12:00:00 AM	ADDRESS	34.17686	-118.46591	TI for single story retail building.  Title 24 plan check per inspector request under permit 14041-90000-09475.  (((Interior TI, Install 10 new receptacles)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67885	15041-10001-04071	10833 W WILSHIRE BLVD	90024	5	132B153   252	4360003023	[Q]R5-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM			PC Approved	05/20/2015 12:00:00 AM	ADDRESS	34.05971	-118.44117	STAMP SETS WERE LOST. PC FOR ENERGY.  (((Title 24 plan check only.  Total area = 3,424 sq. ft. (indoor) + 482 sq. ft. (outdoor)Renovation of existing fitness center.  Installation of new recepticles and lighting.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67886	10041-20001-08910	71 N BEVERLY PARK	90210	5	156B161    52	4386013020	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2013 12:00:00 AM	03/12/2013 12:00:00 AM		Permit Finaled	07/17/2013 12:00:00 AM	ADDRESS	34.12462	-118.41843	Changes to approved set of plans: changes to service and 1 - line, addition of Panel G and loads, addition of heaters to Panel GH, changes to Panel P. Service has been upgraded to 1600A.Plan check new 2-story single family dwelling with 1200A service including guest house and tennis bar. Permit for guest house and tennis bar under #12041-10000-02202. (1 of  2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67887	18041-10000-37890	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.03393	-118.22985	PLAN CHECK FOR POWER AND ENERGY FOR RENOVATIONS TO EXISTING RESTAURANT (NEW RESTAURANT WITH NO CHANGE OF USE) TOTAL AFFECTED AREA = 7232 SF NEW CONNECTED LOAD >400A ON EXISTING 600 DISTRIBUTION SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67888	16041-10000-13348	11111 W SANTA MONICA BLVD 9TH FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.04771	-118.44481	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE BUILDING ON THE 9TH FLOOR LOBBY AND BATHROOM AREAS. SCOPE INCLUDES REPLACING SOME OF THE LIGHTING FIXTURES, RECEPTACLES, AND EXIT SIGNS ON THE 9TH FLOOR. TOTAL AFFECTED AREA IS 1243 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67889	13041-10000-34143	3663 W WILSHIRE BLVD	90010	10	132B193    23	5503027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.06188	-118.30486	Partial renovation of the 1929 Historic School Building and complete renovation of the 1962 School Building.  2 story school and 1 story admin office.  Plan check for power and energy.  45,400 sq ft..  Work under this permit shall not alter or demolish historic features.CRA:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67890	16041-20000-35265	10457 N HANNA AVE	91311	12	207B101   250	2723019145	R1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.26066	-118.60748	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter, (52) modules, and (1) combiner box.$11.23 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67891	14041-10000-25628	7250 N HAZELTINE AVE	91405	2	186B153   714	2216002058	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Apartment			09/17/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.20287	-118.43981	installation of rooftop solar photovoltaic system for multi-family affordable housing.  System size = 22.8 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67892	17041-10000-05470	1051 S ALVARADO ST	90006	1	130-5A201 248	5136013030	C2-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.05072	-118.28078	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR) 24900 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67893	15041-10000-37884	701 E 3RD ST 2nd floor	90012	14	129A215   289	5163009902	[Q]M3-2-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	PIN	34.04581508	-118.23784015	TI TO 2ND FLOOR. PC FOR T24 ENERGY ONLY. NEW LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67894	17041-10000-19619	1542 W 1ST ST	90732	15	018B193   818	7559015014	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	33.74404	-118.31121	PC FOR ROOF MOUNTED PV ON SFD. TOTAL SYSTEM SIZE 5KWAC. 18 MODULES FLEX 270W WITH OPTIMIZER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67895	18041-10000-32788	14301 W NORDHOFF ST	91402	6	198B153   929	2639027009	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Issued	08/28/2018 12:00:00 AM	ADDRESS	34.23557	-118.44365	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67896	16041-20000-26334	333 S GRAND AVE 3600	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	10/06/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Title 24 only in existing high-rise. Total area: 13,516 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67897	11041-10000-26286	901 W OLYMPIC BLVD	90015	9	129A207   293	5138005036	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM	09/20/2012 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.04576	-118.26609	Plan check power and enery for new 23-story Marriot Hotel with 393 rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67898	19041-10000-30792	4073 W WASHINGTON BLVD	90018	10	126B185   948	5072013035	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.04004	-118.328	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67899	14041-10000-35800	3435 W WILSHIRE BLVD # 550	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.06194	-118.29866	Plan check for Title 24 only. Project scipe is a tenant improvement in an existing commercial space. Project site is a suite of a high-rise building. Total lighting area = 7,690 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67900	17041-10000-11997	1551 N WILMINGTON BLVD	90744	15	036B201   416	7414027030	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Issued	04/13/2017 12:00:00 AM	ADDRESS	33.79401	-118.2753	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 23900 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67901	18041-20000-07682	18644 W SHERMAN WAY	91335	3	183B121   150	2126005027	[Q]R1-1L-CDO-RIO, [Q]R3-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Issued	03/02/2018 12:00:00 AM	ADDRESS	34.20095	-118.5401	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACING WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67902	18041-20001-36714	7035 N RESEDA BLVD	91335	3	183B125   454	2126008009	[Q]C2-2D-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.19872	-118.53624	11/30/2018changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.((((pv2install roof mounted pv system sized 12KW AC interconnected with msp.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67903	18041-10000-09126	7640 N TEXHOMA AVE	91325	12	186B129   110	2202003017	RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.20976	-118.51522	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 31 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER. TOTAL SYSTEM SIZE 10.7 KWDC/7.6 KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67904	16041-20002-18010	17330 W SEPTO ST	91325	12	201B129    29	2734031017	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.25126	-118.51221	Revisions to approved set.  Change of module model and manufacturer. $0 plan check fee due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67905	10041-10000-24357	2139 W SUNSET BLVD	90026	13	139-5A207  78	5402034012	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1956.00, 1957.10	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	05/11/2011 12:00:00 AM	ADDRESS	34.07758	-118.2647	Ti for existing restuarant . Power energy and title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67906	13041-10000-07318	911 S HILL ST	90015	9	127-5A209 183	5139004018	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Closed	04/10/2013 12:00:00 AM	ADDRESS	34.04281	-118.2576	NEW FIRE ALARM SYSTEM FOR EXISTING RESTAURANT ON FIRST FLOOR. 2 DEVICES AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67907	19041-20000-37762	18440 W BRYANT ST BLDG B	91325	12	195B125   975	2786005012	P-1VL, [Q]CM-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	01/04/2021 12:00:00 AM		Permit Finaled	06/17/2022 12:00:00 AM	ADDRESS	34.22721	-118.53519	NEW MINOR AUTOMOTIVE REPAIR SHOP HAZARDOUS LOCATION NEW 400 AMP 120/240 3 PHASE SERVICE. PROVIDE PANELS, EQUIPMENTS, AND LIGHTS.BUILDING B BUILDING #: 19010-20000-04093	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67908	13041-10000-23389	9815 W NATIONAL BLVD 1-4	90034	5	123B165   902	4311003022	C2-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	05/15/2017 12:00:00 AM	ADDRESS	34.03155	-118.40025	RENOVATE (E) GAS STATION, ADDITION TO (E) 1ST FL + 2ND STORY, (N) CANOPY.  UPGRADE OF SERVICE TO 1200 A.  CLASSIFIED HAZARDOUS AREAS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67909	18041-30001-24755	9901 W WASHINGTON BLVD 1st&6th FL	90232	5	120B165  1311	4207004034	(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.02174	-118.39786	05/14/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the lighting fixtures being used. Changes have been reflected onto the Title 24 compliance forms.*****Original Work Description*****Plan check for Title 24 Energy only in existing space T.I. 1st Floor commom area and 6th Floor Patio. Total aera: 2455 sq ft.B#18016-30000-20933	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67910	10041-10000-11513	10250 W CONSTELLATION BLVD 16th Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	09/22/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI IN AN EXISTING OFFICE AREA ON THE 16TH FLOOR. PLAN CHECK IS FOR POWER AND ENERGY.Permit is for additional Circuits.  Variance filed to separate the Fire Life Safety System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67911	19041-20000-40795	9716 N ANDORA AVE	91311	12	201B097    92	2724009010	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.24732	-118.62299	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 12.41 KW DC/11.2 KW AC CEC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH OPTIMIZERS AND A 10KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67912	17041-10000-14103	17270 W SATICOY ST	91406	6	186B133   237	2203017045	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.20821	-118.50928	T-24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 1760 SQ. FT. TOTAL OF 7 FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67913	18041-20000-15925	419 N SAINT CLOUD ROAD	90077	5	141B153    62	4362018004	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.08556	-118.43815	PLANCHECK ONLY. Project site is existing 2-story single-family dwelling. Project scope is a complete remodel and addition. Work includes a new 600 Amp service.building and permit under 16014-30000-06144	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67914	10041-10000-19831	6381 W DE LONGPRE AVE 1ST FL	90028	13	147A187   587	5546015040	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	01/20/2011 12:00:00 AM	ADDRESS	34.09629	-118.3275	INTERIOR PARTITION WALL REMODEL & TEE-BAR CEILING IN RETAIL AREA WITHIN PARKING STRUCTURE. ALSO, 4 EA LUMINAIRES INSTALL OUTSIDE IN HARDSCAPE AREAPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67915	13041-10000-26709	380 W WORLD WAY SPC-7C	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	09/26/2013 12:00:00 AM		Permit Finaled	03/25/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN-CHECK FOR SIGN LIGHTING. INSTALLING (3) ILLUMINATED SIGN AT LAX - TERMINAL 7 , (1) ILLUMINATED CEILING FIXTURE. NEW INDOOR SIGNS; NOT INSTALLING LIGHTING CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67916	15041-20004-10807	18209 W PARTHENIA ST	91325	12	195B125   794	2769019041	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM			PC Approved	08/23/2016 12:00:00 AM	ADDRESS	34.2289	-118.52978	8.23.2016 - Plan check for modifications to approved set. Remove panel AC2. Change heat pump for air conditioning unit. Add note specifiying model of time clock. Make switch in warehouse 3-way. Delta 4 changes.=====(7/21/2016)REVISIONS TO AN APPROVED SET OF PLANS.  REVISIONS ARE NOTED DELTA 3 ON PLANS.  THIS IS PLAN CHECK ONLY,  ALSO CHANGE OF CONTRACTOR.Plan check for power and Title-24 (energy).  Total area = 1,170 sq. ft. (unconditioned) + 5,630 sq. ft. (conditioned) + 1,000 sq. ft. (outdoor)Project is a new two story office building connected to new warehouse with common roof above a carport.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67917	15041-20000-23548	10250 W CONSTELLATION BLVD 14th Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for power and lighting. Project site is the 14th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 17,048 sq. ft. Newly connected load is approximately 500 Amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67918	16041-10000-41142	850 W ROSECRANS AVE	90247	15	075B197   228	6119019018	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.90168	-118.29076	TItle 24 plan check.  T.I. to existing McDonald's restaraunt.  New lighting and POS receptacles.  Total area = 1,542 sq. ft. indoor + 2,500 sq.  ft. outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67919	14041-10000-31829	4026 E BEMIS ST	90039	13	159B205   208	5593026001	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.13421	-118.27027	Installation of roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67920	15041-10000-03969	29 E WAVE CREST AVE	90291	11	108A143   245	4226003015	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	33.99011	-118.47522	PV1, INSTALL 3.315 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERECONNECT WITH MAIN SERVICE PANEL.(13) MODULES: TRINA SOLAR # TSM-255PA05.18(1) SOLAREDGE # SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67921	17041-10000-19528	3150-3158 W OLYMPIC BLVD	90006	10	129B193   327	5080022016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Info Complete	06/14/2017 12:00:00 AM	ADDRESS	34.05238	-118.30484	TITLE 24 ONLY  FOR RETAIL SPACE TI(CONVERT SPACE INTO 4 RETAIL SPACES). TOTAL AFFECTED AREA = 3959 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67922	13041-10000-34712	700 S FLOWER ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. WORK ON FLOORS 3 - 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67923	18041-30000-38456	10990 W WILSHIRE BLVD SUITE 900	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.0577	-118.44711	Plan check for Title 24 only in office space in high-rise building. Total area:4,514  sq ft. B#18016-10000-32379	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67924	15041-20000-12892	10814 N WILLOWBRAE AVE	91311	12	207B105   100	2722019037	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2015 12:00:00 AM	05/18/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.26693	-118.59851	PV1. Install roof mounted PV system sized 14.6 kW. Interconnected with main service panel. (69) Kyocera KU255 Modules(1) PVI 3.6 TL Inverter(1) PVI 6000 TL Inverter(1) PVI 5000 TL InverterNote: Permit fees $0.00 due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67925	18041-20000-23437	13052 W GLAMIS ST	91331	7	204B161   260	2623010003	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.25627	-118.41727	Plan check for PV roof mounted system, system size: 4kW with 16 modules and 1 inverter(4.0kW) center feed panel	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67926	17041-20000-18525	6200 N CANOGA AVE ste 200	91367	3	177B105   127	2149001035	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.1833	-118.59719	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67927	14041-10000-29174	4527 W BRAZIL ST	90039	13	165B205    85	5593010017	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	ADDRESS	34.14692	-118.27344	Title 24 plan check only.  Total area = 19,837 sq. ft.T.I. to existing retail space.  Changes to approved set to reflect new service.  PC at applicant's request.Original application # 14041-10000-04062	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67928	12041-10000-10008	8053 W BEVERLY BLVD	90048	5	138B177   392	5514007045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	02/07/2013 12:00:00 AM		Issued	02/07/2013 12:00:00 AM	ADDRESS	34.07625	-118.36499	REPLACEMENT OF SERVICE AND SOME TENANT  PANEL BOARDS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67929	17041-10000-19243	10250 W SANTA MONICA BLVD # 1805	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR POWER AND ENERGY FOR FIRST TIME TENANT ""UNTUCKIT"" WESTFIELD PROJECTTOTAL AFFECTED AREA 732 SQ.FT. INSTALLING NEW LIGHTS RECEPTACLES AND EQUIPMENT."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67930	12041-10000-22110	4109 N MARY ELLEN AVE	91604	5	162B157    67	2385024017	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.14393	-118.41985	"PLAN CHECK FOR ROOF-MOUNTED 3.36KW SUNPOWER ""AC MODULES"" PHOTOVOLTAIC SYSTEM. MODULES LOCATED AT MAIN HOUSE AND POINT OF CONNECTION TO UTILITY LOCATED AT POOL HOUSE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67931	16041-10001-00129	5970 W OLYMPIC BLVD	90019	4	132B177   716	5086025025	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM			PC Approved	02/11/2016 12:00:00 AM	ADDRESS	34.05763	-118.36173	02/11/16Changes to an approved set of plans. All changes made under delta 6. Changes include adding/removing lighting fixtures. Note: permit pulled under PCIS#16041-10000-00129 T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING. TOTAL AFFECTED AREA IS 1325 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67932	17041-30002-20492	1915-1919 S LINCOLN BLVD	90291	11	108B149   119	4241024028	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	03/01/2018 12:00:00 AM	ADDRESS	33.99575	-118.45666	Plan check for Title 24 only in existing space retail. T.I. Total area: 400 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67933	19041-20000-35833	20165 W RINALDI ST #110	91326	12	210B113   290	2701100007	(T)C4-2D, C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	34.27527	-118.57297	TENANT IMPROVEMENT TO CHIROPRACTOR OFFICE P.C FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67934	17041-20001-34732	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD and detached garage.8.88kW ungrounded system.(37) EnPhase M250 microinverters.(37) 290W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67935	18041-20000-23252	22441 W HARTLAND ST	91307	12	183B101   703	2024029010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.19474	-118.61627	Plan check for power only. Project site is a single-family dwelling. Project scope is the addition of (2) Tesla PowerWalls to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67936	18041-20000-09812	178 N ALEXANDRIA AVE	90004	13	138B197   571	5518012038	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2112.01	Electrical	Electrical	Apartment			03/16/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.07498	-118.29827	Plan check for power and energy. Project site is a 4-story, 14-unit apartment building. Work includes a new 800-amp service and a total lighting area of 7,169 sq. ft.Note: Building application has been generated under 16010-20000-06249	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67937	12041-20000-30219	1921 N HIGHLAND AVE	90068	4	150A185   204	5549018001	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			12/14/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	04/03/2013 12:00:00 AM	ADDRESS	34.10577	-118.33774	Adding additional fire alarm devices to an existing hotel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67938	15041-20001-13023	7645 N ROYER AVE	91304	12	186B097    75	2014034046	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM			PC Approved	06/02/2015 12:00:00 AM	ADDRESS	34.20967	-118.62791	Changes to an approved set of plans. Changing module layout.Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  Microinverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67939	19041-10000-25105	6837 N LANKERSHIM BLVD	91605	2	183B169   528	2321018005	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.19501	-118.38798	REMOVE OUTDOOR HID AND REPLACE WITH NEW LED FIXTURES , T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67940	17041-10000-21602	7315 W MELROSE AVE	90046	5	141B181   535	5526008028	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.08368	-118.34926	PC FOR T.I. OF ( E ) RESTAURANT TITLE-24 ENERGY ONLY. TOTAL AFFECTED AREA 1790 SQ.FT.SCOPE INCLUDES NEW EQUIPMENT AND  LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67941	17041-20000-37877	17755 W ALONZO PL	91316	5	165B129    33	2182025011	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.15233	-118.52	Addition of (2) tesla power walls.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67942	13041-20000-32036	1840 S CENTURY PARK EAST #700	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.06188	-118.41473	Change to lighting in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67943	14041-10000-09001	13151 W LAKE ST	90066	11	114B149   583	4244014030	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	06/24/2014 12:00:00 AM	ADDRESS	34.00838	-118.45281	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTERS: SOLAREDGE SE3000A-US-ZB-U &(14) MODULES: TRINA SOLAR TSM-250PA05.18REVISION TO APP3 13041-20000-33141	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67944	18041-20001-32871	22641 W OXNARD ST	91367	3	177B097   482	2039017023	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM			PC Approved	09/04/2018 12:00:00 AM	ADDRESS	34.17931	-118.62026	expeditepv1install roof mounted pv system sized 30.4KW AC interconnected with msp.(93) sc 320 Watts modules(3) solaredge inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67945	16041-10000-23647	7441 W WOODROW WILSON DR	90046	4	156B177   257	2427012021	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.12423	-118.35693	Fees are $0  due to bill 1222System size changed to 11.4KWacTotal panaels and optimizers is 40.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.6KWac.(50)MODULES-SUNIVA 285W(50)OPTIMIZERS-SOLAREDGE P300(2)INVERTER-SOLAREDGE SE5000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67946	11041-10002-18773	2005 N HIGHLAND AVE	90068	4	150A185   119	5549030013	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			02/07/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	03/02/2012 12:00:00 AM	ADDRESS	34.10671	-118.33767	Plan check for revision to approved plans. Delta 5 revisions. Panels relocated to a different service, change to rooftop equipment.<<<<Renovation of a 7 story hotel , addition of 10 new panels, 377 new branch ckts, title 24 energy. power and lighting.  >>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67947	13041-10000-34319	8900 N CORBIN AVE	91324	12	195B117    43	2783025026	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1134.01	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.23252	-118.56211	Full plan check for shell station and carwash. Title 24 for outdoor and indoor lighting. Area for indoor and outdoor lighting 21449 sq ft. Carwash is the scope of the project. All circuits are reworked and new branch circuits are added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67948	17041-20000-22246	330 S ALAMEDA ST Grd Flr &-Mezz	90013	14	127-5A215 134	5163010007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.04394	-118.23787	Plan check for energy only. TI to commercial office building. New lighting (incl. emergency) - 6,988sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67949	13041-10001-35372	2310 S GLENCOE AVE	90291	11	111B149  1063	4242034018	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.99797	-118.44804	Expedited RSES plan check per applicant request.{{PV1, Install 3 kW DC roof-mounted solar array, interconnect with main service panel for a house. (1)Transformerless inverter: Solaredge SE 3000A-US. (12) modules YINGLI YL250P-29b.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67950	17041-10000-16846	9901 N LURLINE AVE	91311	12	201B109    59	2741002006	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			Corrections Issued	05/22/2017 12:00:00 AM	ADDRESS	34.25058	-118.58431	TENANT IMPROVEMENTS OF LEASING OFFICE WITH 249 SF ADDITION. pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67951	18041-20000-30365	20530 W SHELLEY LANE	91326	12	213B109   787	2701094032	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.28195	-118.58105	pv1install roof mounted pv system sized 5.7KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67952	19041-10000-06395	6600 N TOPANGA CANYON BLVD # 2036	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TITLE 24 ONLY FOR - T. I. TO EX. RETAIL STORE (2,638 SF) FOR SUITE 2036 TOTAL AFFECTED AREA = 2638 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67953	18041-20000-39972	11445 W RIVERSIDE DR	91602	2	168B169   425	2354012051	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Apartment			10/18/2018 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	04/30/2021 12:00:00 AM	ADDRESS	34.1578	-118.38056	Plan check for power and energy. Project site is a 3-story, 29-unit aparment building. Work includes a 1,600 amp service and a total lighting area of 22,480 sq. ft.Note: Building application has been filed under 17010-20000-02067	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67954	17041-10000-14814	7503 N CAMELLIA AVE	91605	2	186B169   470	2316011037	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2017 12:00:00 AM			Corrections Issued	05/04/2017 12:00:00 AM	ADDRESS	34.20684	-118.38246	PC FOR PV SYSTEM ROOF MOUNTED 3KW AC 12 MODULES TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67955	19041-20001-10896	9930 N OWENSMOUTH AVE NO 3	91311	12	201B105    38	2747014***	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.25082	-118.60153	PV1. INSTALL 4.41 KW DC PV SYSTEM WITH (14) MODULES/OPTIMIZERS AND (1) INVERTER (SE3800)NOTE: INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-10896	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67956	16041-20001-15172	13640 W ROSCOE BLVD	91402	6	192B157   676	2213021020	P-1VL, [Q]C1-1, [Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.2215	-118.42999	Change to carport lighting fixture type and quantity.  (((PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORTS. 69,142 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67957	18041-10003-02493	1353 W 60TH PL	90044	9	105B197   439	6003017023	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Expired	10/05/2018 12:00:00 AM	ADDRESS	33.98513	-118.2998	Supplemental PC for battery install and 5kW autotransformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67958	13041-20000-17246	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM	06/28/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	NEW LIGHTING IN OFFICES. TOTAL AREA 944 SQ FT. PC FOR T24 ENERGY ONLY. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67959	14041-20000-13472	16726 W OAK VIEW DR	91436	5	168B137   383	2289021004	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.15726	-118.49872	PV1.  Install roof-mounted PV system, interconnect with main service panel. Microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67960	17041-10001-01478	832 S OLIVE ST	90014	14	127-5A209  95	5144018026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.04427	-118.25743	11/3/2017CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON CLOUDED AREAS DELTA 1 AND 2. CHANGES INCLUDE REVISION OF CIRCUITS AND LOAD CALCS WITH AN ADDITION OF A PANEL FOR HVAC UNITS. ***PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT AND MICROBREWERY. NEW OUTDOOR DINING.  OCCUPANCY LOAD IS 152 PER ARCHITECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67961	13041-10002-30169	16645 W GRESHAM ST	91343	12	195B137   508	2688040037	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.23091	-118.49553	Expedited RSES plan check per applicant request. ((((PV1, Install 5.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US. 23 modules Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67962	18041-20000-20275	508 N GULF AVE	90744	15	030B205  1121	7417014025	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	33.77543	-118.27237	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67963	14041-10000-33752	2057 N MEADOW VALLEY TER	90039	4	147A205    66	5431004001	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.09885	-118.27175	Installation of new roof mounted solar PV array.  Total system size = 6.6 kWac. FEE AMOUNT REFLECT ON SENATE BILL 1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67964	17041-30000-27791	6101 W IMPERIAL HWY	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	33.93236	-118.39253	Plan check for Title 24 only for Air Cargo Termal(Korean Airlines) - LAX replace existing lighting fixtures with new lighting fixtures in Cargo Facility. Total area indoor and outdoor: 105,330 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67965	17041-20000-35189	8527 N SEPULVEDA BLVD	91343	6	192B145   119	2654020015	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.22544	-118.46799	PV2. ROOFMOUNTED SOLAR SYSTEM &  CARPORT WITH ROOFTOP SOLAR SYSTEM ( carport under application # 17041-20000-35194 ) SYSTEM SIZE: 60 KW AC TOTAL.17010-20000-03781    building permit	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
67966	18041-10001-43380	12280 W MONTAGUE ST	91331	7	204B165   203	2537018022	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.25522	-118.40059	REVISED SERVICE CONDUCTORS AND ADDED SERVICE RATED DISCONNECT NEXT TO THE DISTRIBUTION BOARD (((((FULL PC FOR POWER AND ENERGY. CONVERT (E)  ELECTRO PLATING MANUFACTURER BUILDING TO (N) HYDROPONIC AGRICULTURAL ENTERPRISE. SCOPE INCLUDES A NEW 4000A SERVICE/DISTRIBUTION BOARD, NEW  PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 12080 SQ. FT. B#18016-10000-31816	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
67967	19041-10000-07217	20101 S HAMILTON AVE	90502	15	054B197   127	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/28/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	33.84769	-118.28637	Energy plan check for an office T.I located in the first floor of a commercial building. Scope includes new lighting and equipment with a total area of 17, 103 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67968	17041-20000-03041	8800 S HOOVER ST	90044	8	096A201    80	6038013900	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	33.95787	-118.28682	New outdoor lighting for pool facilities and interior lighting for pool house pump rooms and lifeguard room.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67969	15041-20001-27757	9449 N BIANCA AVE	91325	12	198B129    34	2766019003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.24276	-118.5143	Expedited per customer request.PV1. Install roof mounted PV system sized 10.2 kW. Interconnected with main service panel. (45) KU265 Modules(1) PVI-3.0 (2) PVI-3.6 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67970	17041-10000-13779	10940 W WILSHIRE BLVD suite 2050	90024	5	132B153   461	4324001032	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM			PC Approved	04/26/2017 12:00:00 AM	ADDRESS	34.05822	-118.4452	pc for TI, TITLE 24 ENERGY ONLY FOR 2ND FLOOR OFFICES IN HIGH RISE BUILDING. THIS IS A PLAN CHECK ONLY, PERMIT PULLED UNDER 17041--40000-11027.TOTAL AFFECTED AREA 1810 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67971	11041-10000-07748	633 W 5TH ST 66TH FL	90071	9	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN EXISTING OFFICEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67972	18041-30000-31741	10717 W OHIO AVE 1-3	90024	5	132B153   583	4325013018	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/16/2021 12:00:00 AM	ADDRESS	34.05724	-118.43561	FULL PLAN CHECK FOR PROPOSED 3-STORY, 3-UNIT CONDOMINIUM WITH BASEMENT GARAGE.SERVICE AT 600A DELTA SYSTEM. TOTAL COMMON AREA: 4325 SQ.FT (2017 LABC COMPLIANCE PER 15010-10000-03432)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67973	11041-10001-14514	7149 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/01/2012 12:00:00 AM			Corrections Issued	03/01/2012 12:00:00 AM	PIN	33.94386821	-118.41794839	NEW FIRE WATER DELUGE PUMP BUILDING AT LAX.  FULL PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67974	16041-20000-30817	18840 W VENTURA BLVD	91356	3	174B121   503	2161003001	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.17186	-118.54425	Plan check for power and energy. Project site is an existing commercial medical building. Project scope is a service upgrade to 1,600-amps and lighting within the electrical room. Total lighting area = 179 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67975	17041-20001-44251	10915 N INDEPENDENCE AVE	91311	12	210B109   249	2706003003	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.26869	-118.59086	Expedited per applicant request.Plan check for a PV1 ground-mounted PV system. System size is 11.2 kWac and consists of (40) modules, (40) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67976	14041-20001-18517	23601 W LADRILLO ST	91367	3	171B093   314	2047006009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM			PC Approved	07/21/2014 12:00:00 AM	ADDRESS	34.1659	-118.641	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD. System size: 12kW.(2) SolarEdge SE6000A-US-ZB-U transformerless inverters(53) SolarEdge P300 power optimizers(53) Trina Solar #TSM-255PA05.18 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67977	18041-10000-31164	1100 S GLENDON AVE #715	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.06074	-118.44418	PLAN CHECK FOR ENERGY ONLY FOR - TENANT IMPROVEMENT. NON-STRUCTURAL INTERIOR PARTITION. - TOTAL AFFECTED AREA = 1328 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67978	14041-10000-31375	5176 W SANTA MONICA BLVD	90029	13	144B193   729	5537019006	[Q]C2-2D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.09057	-118.30279	PROPOSED REMODEL OF EXISTING WAREHOUSE- DIVIDE 1ST AND 2ND FLOORS INTO SMALLER WAREHOUSE SPACES (NO CHANGE IN USE),  NEW MEZZANINES AT FRONT AND REAR OF BLDG.Note : corrected sset of plans will show relocated swtchboard and new electrical room	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67979	14041-20000-23860	19752 W SHERMAN WAY	91306	3	183B117    65	2135016011	C4-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.20087	-118.56402	TI FOR A NEW RESTROOM LIGHT.  TITLE 24 ENERGY PLAN CHECK 50SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67980	15041-20000-39920	4352 W CAMERO AVE	90027	4	148-5A201 190	5542005022	R2-1XL	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Expired	12/29/2017 12:00:00 AM	ADDRESS	34.10078	-118.28407	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3KWac. (14) MODULES-SOLAR WORLD 275W MONO BLACK(14)OPTIMIZERS-SOLAR EDGE POWER OPTIMIZER P300-5NC4ARS(1)INVERTERS-SOLAREDGE SE3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67981	13041-10000-26236	915 N LA CIENEGA BLVD	90069	5	144B173   341	4337001038	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.08734	-118.37659	TITLE-24 PLAN CHECK ONLY FOR A RETAIL SPACE IN A SINGLE-STORY BUILDING. EXISTING PERMIT UNDER #13041-90000-19052	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67982	12041-10000-16482	2718 W IVAN HILL TER	90039	4	150A207   111	5439011011	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	09/12/2012 12:00:00 AM	ADDRESS	34.10643	-118.26311	Plan check for new roof mounted 1.92KW photovoltaic system (SolarEdge transformerless inverter) with DC-DC powerbox. Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67983	16041-20001-38672	7858 W DENIVELLE ROAD	91040	7	210B193   241	2552013012	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM			PC Approved	11/23/2016 12:00:00 AM	ADDRESS	34.27226	-118.30459	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17.6KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67984	19041-10001-36022	16819 N NORDHOFF ST	91343	12	198B133   615	2687005008	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.2359	-118.49879	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE ADDITION OF 2 MODULES. TOTAL SYSTEM SIZE IS 5.415 KWDC / 3.8KWAC_______________________Plan check for a PV1 3.8KW AC / 4.8KW DC roof mounted system. Scope includes (1) inverter, (20) modules and optimizers interconnecting through the main service panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67985	19041-20000-31533	12426 N SAN FERNANDO ROAD	91342	7	219B149   516	2507007023	P-1-CPIO, [Q]M1-1-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Issued	11/12/2019 12:00:00 AM	ADDRESS	34.29621	-118.45435	Plan check for Title 24 Energy only Tenant Improvement Indoor Nursery, newly connected load less than 400A. Total area: 7,790 sq ft. B#18016-20000-20311	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67986	16041-10000-19279	18247 W SHERMAN WAY	91335	3	183B125   102	2119028007	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM			Reviewed by Supervisor	06/13/2016 12:00:00 AM	ADDRESS	34.20134	-118.53122	Full PC. TI on existing commercial space for (N) Harbor Freight Tools shop. New distribution boards and new panels (per applicant), 1000 A service. Total area: 16,779 sq. ft.B# 16016-40000-12277	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67987	13041-10002-25634	453 S SPRING ST	90013	14	129A211    87	5149024001	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/21/2013 12:00:00 AM	ADDRESS	34.04778	-118.24948	SINGLE 3PH INVERTER CHANGED TO 5 EA 1PH INVERTERS; AC DISCONNECT & INVERTERS RELOCATED RELOCATEDPV2.  Roof-mount commercial high-rise, 65.8 kW DC.  1 central inverter: Fronius CL 55.5 Delta.  280 panels: TaleSun TP660PNOTE TO CASHIER:ROOF-TOP MOUNTED SYSTEM MAXIMUM FEE HAS BEEN REACHED PER SENATE BILL; PERMIT FEE IS O	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67988	10041-20000-14563	11333 W VENTURA BLVD	91604	2	162B173   409	2366036020	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM	07/29/2010 12:00:00 AM		Issued	07/29/2010 12:00:00 AM	ADDRESS	34.14041	-118.37706	MISC. PERMIT TO RE-WIRE (E) OFFICE BUILDING, TO COMPLY WITH TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67989	10041-10000-08746	6600 N TOPANGA CANYON BLVD #9015	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/11/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	05/19/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR LOAD FOR  KIOSK SPACE #9015.  PERMIT EXIST ON PERMIT # 10041-10000-04004.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67990	14041-20000-22873	8259 W MELROSE AVE	90046	5	141B173   405	5528003199	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.08383	-118.36944	CHANGEOF USE FROM RETAIL TO BEAUTY SALON (1,870.0 SF). ADD NEW NON-BEARING PARTITION WALLS TO ENLARGE LUNCH ROOM, ADD NEW DRESSING ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67991	15041-10001-06518	6344 N TOPANGA CANYON BLVD BLDG A	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.18628	-118.60544	(((7/9/2015- CHANGES MADE TO APPROVED SET. ADDING NOTE 21 TO ALL THE TENANT SPACES. CALCULATIONS TO BE REVERIFIED. ALL PERMIT FEES FOR REVISIONS ARE ON BUILDING A APPLICATION 15041-10001-06518)))NEW FIRE ALARM SYSTEM IN BUILDING A ON WESTFIELD PLAZA. 134 DEVICES AND ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67992	15041-20001-22420	5005 N GREENBUSH AVE	91423	4	171B157  1059	2359007011	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.16144	-118.42593	**PC ONLY, PERMIT UNDER 15041-90000-22420**Installation of roof-mounted solar PV1 system 7.98 kWDC(28) modules: SW285 MONO(1) inverter: SB7000TL-US-22	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67993	18041-10000-01052	2915 W LOS FELIZ BLVD	90039	13	157-5A207 373	5594006021	[Q]C4-1XL-RIO-POD, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.12679	-118.26282	PC for T24 only for retrofit lighting and outdoor lighting. One for one conversion of flourecent lighting to LED lighting using GE retrofit kits.  Installing new outdoor fixture and using retrofits to convert flourecent lighting to LED lights. Total area is 19,992sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67994	16041-10000-28773	20333 S NORMANDIE AVE	90501	15	054B197    45	7351020021	M2-1VL, PF	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	33.84604	-118.29972	Proposed New Industrial Core and Shell,  Type IIIB Construction  with Mezzanine. NEW 2000A SERVICE, SITE LIGHTING, AND FIRE PUMP CONTROL EQUIPMENT. FULL PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
67995	17041-10000-34423	10967 W WEYBURN AVE	90024	5	135B149   594	4363017009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	34.06238	-118.44766	PC FOR T.I. (BAKERY) TAKE OUT TO A SIT DOWN CONCEPT FOR TITLE 24 ENERGY ONLY. SCOPE INCLUEDS NEW EQUIPMENT LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 1054 SQ.FT. B#17016-10000-28047	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67996	19041-20000-32207	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476005010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	09/03/2020 12:00:00 AM	ADDRESS	34.12626	-118.21412	T24 PLAN CHECK FOR TI TO EXISTING COMMERCIAL BUILING. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1840 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
67997	18041-10000-46539	7032 N COMANCHE AVE	91306	3	183B113   279	2135005015	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.19869	-118.57231	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 15 MODULES (QCELL 305) , 15 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 4.58KWdc and 3.8KWac.THIS SYSTEM IS COMBINED WITH AN EXISTING SYSTEM WHICH CONSIST OF 4 MODULES (SOLARWORLD 250W) AND 4 MICROINVERTERS (ENPHASE M215), EXISTING SYSTEM SIZE IS 0.86KWac AND 1KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67998	18041-20000-46970	13401 N ANDALUSIA LANE	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.31477	-118.4223	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) micro-inverters and (7) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
67999	17041-10000-23807	902 S 4TH AVE	90291	11	108B145   604	4239010022	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			07/14/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	33.99368	-118.47158	PV2. NEW ROOF MOUNTED SOLAR SYSTEM FOR AN EXISTING MULTI-FAMILY RESIDENTIAL(COMMERCIAL). TOTAL SYSTEM SIZE IS 3.0KWac.(7)MODULES-TRINA SOLAR#TSM-300DD05A.18(1)INVERTER-ABB#PVI3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68000	11041-20000-05179	530 W 27TH ST Leasing-Office	90007	9	121-5A203 130	5123018019	(T)(Q) C2-2, D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.0269	-118.27607	Plan check power and energy portion of use from retail to leasing office and  first time tenant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68001	14041-10001-15970	2255 W COLORADO BLVD	90041	14	162A221    71	5671016001	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	08/21/2014 12:00:00 AM	ADDRESS	34.13956	-118.21544	((((8/15/2014 - Supp. app. for title 24 only.  total area = 865 sq. ft.))))Master permit work description: SWITCHES AND PANEL UPGRADE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68002	15041-10000-12323	1552 W ROCKWOOD ST	90026	13	135A207   285	5159013016	RD1.5-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.06355	-118.26143	NEW FIRE ALARM SYSTEM 146 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68003	19041-20001-02234	221 W E ST 1-10	90744	15	030B205  1039	7418004008	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Issued	12/13/2019 12:00:00 AM	ADDRESS	33.77562	-118.26428	07-09-2019 Changes to an approved set of plans, Changes include addtion of Electrical Cloth Dryer in each unit and add central circular pump water heater. Revised load calculation, feeder sizes, relocated HP panel and reduction of elevator size to 25HP. All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68004	10041-10000-09186	3641 S HOLDREGE AVE #  B	90016	10	117B173    96	4204008070	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	05/18/2010 12:00:00 AM		Permit Finaled	06/02/2010 12:00:00 AM	ADDRESS	34.01958	-118.37848	T.I. for exist office building.  Install general and emergency lighting.  Plan check for Title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68005	12041-10000-03498	11262 W VENTURA BLVD	91604	2	162B173   435	2378010008	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	02/15/2012 12:00:00 AM		Permit Finaled	10/04/2012 12:00:00 AM	ADDRESS	34.14102	-118.37532	Plan check T24 Energy/Emergency lighting for restaurant TI. Permit for new 400A service, switchboard, panel, and branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68006	18041-10002-23846	4238 S 7TH AVE	90008	10	114B189  1370	5023017038	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.00602	-118.32467	FEE EXPEDITEDPV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(11)MODULES-LG330N1(11)OPTIMIZERS- SOLAREDGE OPTIMIZERS(1)INVERTER-SOLAREDGE SE7600A-USS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68007	17041-10000-13258	4527 N MORELLA AVE	91607	2	168B169   998	2364006011	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	34.1529	-118.39008	PV INSTALLATION OF A NEW 13.9 KW DC/12 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68008	15041-10000-03692	4551 N GRIFFIN AVE	90031	1	147A225   164	5303004026	[Q]RD3-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.09497	-118.20227	Installation of roof mounted solar PV array.  Total system size = ??? kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68009	13041-10000-24152	4170 S PADILLA PL	90008	8	114B177    37	5029017***	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			09/04/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.00964	-118.3624	FA (N) FOR BALDING HILLS (N) COMMUNITY BUILDING. 1 panel, 1 annunciator, 1 battery cabinet, and 22 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68010	18041-10001-45776	15833 W VOSE ST pv1	91406	6	183B141   284	2224005004	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2019 12:00:00 AM			PC Approved	02/25/2019 12:00:00 AM	ADDRESS	34.19855	-118.47829	Plan check for a lost set of plan.Permit is under 18041-20000-45776 (((pv1install roof mounted pv system sized 3KW AC interconnected with msp.  this is an addition to an existing pv system.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68011	18041-10000-01766	1632 S 5TH AVE	90019	10	126B189   427	5072023018	RD2-1XL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2018 12:00:00 AM	01/17/2018 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.04259	-118.32233	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 3.48KWDC/ 3.8KWACSCOPE INCLUDES 12 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68012	14041-10000-14510	1075 N VILLA GROVE DR	90272	11	129B129   356	4409006014	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.04995	-118.51364	PV1, INSTALL 7.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68013	16041-10001-33580	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			09/22/2016 12:00:00 AM			PC Approved	12/19/2016 12:00:00 AM	ADDRESS	34.03982	-118.24098	EXPEDITE PER APPLICANT REQUEST. (((((PV2. NEW SOLAR SYSTEM ON EXISTING APARTMENT BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 10.00 KWac.(1)INVERTERS-SOLAREDGE 10000A-US(36)SOLAREDGE OPTIMIZERS-P400(36)MODULES-CANADIAN SOLAR CS6X320P	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68014	18041-10000-30598	6760 N TOPANGA CANYON BLVD	91303	3	180B101   823	2139004020	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.19341	-118.6057	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - 7/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68015	14041-10001-30249	19310 S PACIFIC GATEWAY DR	90502	15	057B197     9	7351031030	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM			PC Approved	11/07/2014 12:00:00 AM	ADDRESS	33.85616	-118.29473	"changes to approved set by replacing lighting fixture type ""D"". all changes are under delta -1 (((Energy plan check for a T.I office. total area covers 15000 SQ feet.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68016	18041-10000-48109	11050 W ARMINTA ST 1-110	91352	6	189B173   477	2314008041	(T)(Q)R3-1, (T)(Q)R3-1-CUGU, QRD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	Apartment			12/19/2018 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	02/09/2021 12:00:00 AM	ADDRESS	34.21377	-118.37214	POWER AND ENERGY PLAN CHECK FOR A NEW MULTI-FAMILY 4 STORY BUILDING WITH 110 UNITS. B# 15010-10000-01761	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68017	19041-10000-26105	4060 W WASHINGTON BLVD	90018	10	126B185   996	5060008004	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.01	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Issued	07/09/2019 12:00:00 AM	ADDRESS	34.03968	-118.32772	NEW SPRINKLER MONITORING SYSTEM WITH 25 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68018	10041-20000-15750	2019 E 7TH ST	90021	14	124-5A217 224	5164020015	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM			PC Approved	08/12/2010 12:00:00 AM	ADDRESS	34.03473	-118.23158	Revision to approved plan . energy plan check on existing permit 10041 20000 06793.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68019	19041-10000-02810	5522 W VENICE BLVD	90019	10	126B177   402	5064009016	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	ADDRESS	34.04364	-118.35964	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68020	14041-10000-25898	8517 N KESTER AVE	91402	6	192B149   144	2653014012	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.22526	-118.4576	Solar PV standard plan. # of inverters = 1. System size = 6kW.  # of modules = 26.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68021	15041-20000-24704	6922 N WHITAKER AVE	91406	6	183B137   332	2225013003	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.19629	-118.49787	Installation of new roof mounted solar PV array.  Total system size = 5.805 kWac.  Microinverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68022	18041-20000-17983	20617 W CHESTNUT CIR	91326	12	216B109    14	2701001040	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.29293	-118.58358	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68023	19041-20000-18856	112 S ROBERTSON BLVD	90048	5	138B169   408	4334005005	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.07485	-118.3836	Change of use from retail to beauty salon and TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68024	16041-20000-04031	11548 W MAGNOLIA BLVD	91601	2	171B169   436	2354004076	R4-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.1646	-118.38335	Install (N) fire alarm system in (N) portable temporary building.  (1) new FACP and (33) signaling and notification devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68025	15041-20001-10745	3855 W BOYCE AVE	90039	13	156A207    84	5435008019	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	34.12314	-118.2626	Expedite per applicant request*********Plan check for PV1 roof mounted 6.0kW system with 16 modules(SUNPOWER SPR-X21-3545) and 1 inverter(SB6000TL0US-22)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68026	13041-10000-33388	2440 S SEPULVEDA BLVD STE 220	90064	5	123B153   135	4256008***	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.03617	-118.43421	"POWER PLAN CHECK TO INSTALL (2) ATS AND (2) FEEDERS APPROX. 300' LONG FROM GENERATOR SWBD IN AN 2-STORY BUILDING. THE NEW AUTOMATIC TRANSFER SWITCHES ARE NOT FOR LIFE-SAFETY PURPOSES PER APPLICANT; THESE ARE OPTIONAL STANDBY PER APPLICANT.   ADDITIONAL NOTES: DESIGN BUILD PLAN; LOCATION OF NEW ""ATS-H"" AND ""ATS-P1"" ARE NEAR SERVICE ROOM. LOCATION OF EXISTING GENERATOR & EMERGENCY SWITCHBOARD ""GB"" ARE LOCATED ON SOUTH LOADING DOCK."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68027	18041-20000-05959	1814 N WEBSTER AVE	90026	13	145-5A205 296	5431031009	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Issued	02/16/2018 12:00:00 AM	ADDRESS	34.0922	-118.26919	PLAN CHECK FOR BATTERY BACK UP SYSTEM WITH EXISTING PV SYSTEM - SYSTEM INCLUDES (2) TESLA POWER WALLS (14KWH). BATTERIES TO CHARGE UNDER EXCESS PV CONDITION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68028	10041-20000-10093	5864 N LANKERSHIM BLVD	91601	4	174B169    46	2338013037	[T][Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM	06/02/2010 12:00:00 AM		Permit Finaled	07/07/2010 12:00:00 AM	ADDRESS	34.17736	-118.38194	600 A SERVICE UPGRADE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68029	16041-10000-42097	955 W ADAMS BLVD 1-19	90007	1	123A201    75	5124010021	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Info Complete	02/06/2017 12:00:00 AM	ADDRESS	34.03148	-118.28302	PC FOR POWER UPGRADE ONLY. PROVIDING NEW 800A SERVICE TO REFEED EXISTING METERING SECTION. PROVIDING NEW 300A SERVICE SECTION TO POWER NEW AC WALL UNITS INSIDE HOUSEING UNITS. TOTAL OF 37 AC ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68030	17041-20000-34165	14337 W JOY DR	91331	6	198B149   660	2644027250	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24135	-118.44589	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68031	18041-10000-10005	5438 W 104TH ST	90045	11	090B173   310	4129034012	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	04/17/2018 12:00:00 AM	ADDRESS	33.94177	-118.3755	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68032	14041-20000-07541	8200 N HASKELL AVE	91406	6	192B141   509	2673022049	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM			Corrections Issued	03/20/2014 12:00:00 AM	ADDRESS	34.21939	-118.47475	T.I. to existing buildingon 1st. and 2nd floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68033	12041-10000-03860	6730 N SUNNY BRAE AVE	91306	3	180B109   109	2148001006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2012 12:00:00 AM	03/08/2012 12:00:00 AM		Permit Finaled	04/17/2012 12:00:00 AM	ADDRESS	34.19293	-118.5806	New 5.04 KW roof mounted photvoltaic system for single family dwelling. Transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68034	17041-20000-28625	2545 W SAN FERNANDO ROAD	90065	1	150B213   434	5457008030	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM			PC Info Complete	11/27/2019 12:00:00 AM	ADDRESS	34.10796	-118.24079	Plan check for energy only.  2-story addition of music rehearsal rooms/music studios to existing 2-story commercial building. New lighting (incl. emergency): indoor-4,794sqft; outdoor-554sqft.Note: Building application has been generated under 14014-10000-03941	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68035	13041-10000-36138	9544 N WYSTONE AVE	91324	12	201B121   709	2762037039	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Expired	03/08/2016 12:00:00 AM	ADDRESS	34.24424	-118.54634	PV1, Install 12 kw DC roof-mounted solar array for a two story house, interconnect with main service panel. (2)Transformerless inverter(s): Power- One Aurora PVI-4.2-outd-S-US, (48)Modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68036	17041-10000-43688	920 W BATTERY ST	90731	15	021B197   248	7445013044	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	33.75483	-118.29725	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.80KWdc / 4.80KWac.(20)MODULES-HiS-S290RG(BK)(20)MICROINVERTERS-IQ6-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68037	18041-10000-31260	4714 S AVALON BLVD	90011	9	111A207    31	5108007021	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2292.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.0002	-118.26503	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68038	18041-10000-26167	1640 W 190TH ST	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	33.85814	-118.30849	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68039	19041-10000-12658	5550 W PICO BLVD	90019	10	129B177   796	5069019026	C4-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Apartment			04/08/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	11/17/2022 12:00:00 AM	ADDRESS	34.04945	-118.35966	Full plan check for a mix-use apartment building. Scope includes (1) 2000-Amp 120/240 3phase 4-wire  service with (6) typical unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68040	12041-10004-30782	12751 W MILLENNIUM A	90094	11	102B161  1175	4211033020		West Los Angeles				2756.02	Electrical	Electrical	Apartment			08/07/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	Modfications to approved set.  Additional house panels and associated loads and deletion of one elevator and associated changes.   Delta revisions 38 and 78, and RFI 2728, 2730, and 2738.(((PLAN CHECK POWER AND ENERGY FOR BUILDING A. FIRST LEVEL RETAIL WITH 3 STORY OF 96 UNITS RESIDENTIAL BUILDING ON TOP OF COMMON SUBTERRANEAN PARKING GARAGE. SITE LOCATED IN METHANE ZONE. Modification to separate fire alarm system has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68041	14041-10000-03335	11124 N CABRIOLE AVE	91326	12	210B121   262	2717007033	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	05/19/2014 12:00:00 AM	ADDRESS	34.27231	-118.54095	"PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 14.75 KW DC.  ""$ 0 permit fee is due to the 2012 Senate Bill No. 1222""(59) SOLAR WORLD SW 250(59) ENPHASE M215"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68042	18041-20000-11691	12032 N CARABELA CT	91326	12	216B109   283	2701083005	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.2915	-118.58278	pv1install roof mounted pv system sized 4.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68043	19041-10000-30854	3912 N EAGLE ROCK BLVD	90065	1	154-5A217  57	5460002006	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.02	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.11909	-118.23035	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68044	19041-10000-48632	1828 E CESAR E CHAVEZ AVE #605	90033	14	130-5A221 325	5174008022	C2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	06/29/2020 12:00:00 AM		Permit Finaled	09/30/2020 12:00:00 AM	ADDRESS	34.05014	-118.21571	FULL PLAN CHECK FOR A MEDICAL OFFICE TI. SCOPE INCLUDES RECEPTACLES, LIGHTING AND CONTROL. TOTAL AFFECTED AREA IS 3,618 SQ.FTPER BUILDING PERMIT # 19016-20000-07254CHANGE OF USE FROM EX. MEDICAL OFFICE (3762 SF) TO MEDICAL CLINIC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68045	11041-10000-18259	10100 W SANTA MONICA BLVD 14th floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	09/12/2011 12:00:00 AM	ADDRESS	34.06191	-118.41691	T-24 and  emergency lighting plan check for a portion of the 14th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68046	19041-30000-52167	1123 S SHENANDOAH ST 1-15	90035	5	132B169   614	4332018042	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM	06/10/2021 12:00:00 AM		Permit Finaled	06/09/2023 12:00:00 AM	ADDRESS	34.05637	-118.38173	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK IS A NEW 800A SERVICE (3P,4W, 120/240) THAT FEEDS A 600A MULTI-MEETRING CENTER THAT FEEDS 15 SUBPANELS, THE 800A SERVICE ALSO FEEDS  400A HOUSE BOARD THAT SUBFEEDS A NEW ELEVATOR AND A NEW HOUSE PANEL. TOTAL AFFECTED AREA IS 16,430 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68047	19041-20000-42575	4707 N FULTON AVE	91423	4	168B157   505	2360021045	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	11/10/2020 12:00:00 AM	ADDRESS	34.15598	-118.42268	NEW FIRE ALARM SYSTEM IN A NEW BUILDING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68048	12041-20000-19127	1220 N HIGHLAND AVE Suite 100	90038	4	144B185   386	5532005038	C2-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	08/14/2012 12:00:00 AM	ADDRESS	34.09323	-118.33841	T-24 lighting plan check for REMODEL OF (SUITE 100)  OF OFFICE AREA ON THE FIRST FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68049	14041-20000-10989	4827 S CENTRAL AVE 1-118	90011	9	111A209   103	5108021026		South Los Angeles				2292.00	Electrical	Electrical	Apartment			04/25/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	33.99948	-118.25668	Remodeling to high rise residential.  Add one 100A subpanel.  All panels, branch circuits, feeders, and branch circuit conductors are existing and to be remained.  Install outdoor lighting.  Plan check for power and energy.Note: A variance to have exit sign on 90 minutes battery backup submitted on 6/9/2014.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68050	19041-20000-15543	1033 S HILGARD AVE PV1	90024	5	132B153   150	4360002033	[Q]R3-1-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	08/20/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	34.06076	-118.44212	PV2.  Install 44kW DC/40.12kW AC-CEC roof mounted grid tied PV system.  (110) modules with (3) SE10000H inverters, A SE7600H inverter, and a 200A panel$0 PERMIT FEE DUE TO SB1222 AND AB1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68051	15041-20000-08333	550 S HILL ST	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/23/2015 12:00:00 AM	ADDRESS	34.04753	-118.25268	TI to existing high rise commercial building (jewelery store). Title 24. Plan check for energy only including emergency. 1,283 Total Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68052	15041-20000-42289	13928 N BALBOA BLVD	91342	7	228B137   219	2603025027	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.32344	-118.49127	Plan check for Title 24 only in existin office T.I.  Total area: 1760 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68053	17041-10000-29833	1428 W PACIFIC COAST HWY	90710	15	033B193    80	7411007028	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.7893	-118.30228	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68054	18041-10000-08493	10250 W SANTA MONICA BLVD DELTA-37	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Issued	03/08/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	Supplemental plan check for Landlord's plan noted under Delta 37: to provide (2) conduit only to tenant #2510 (fed from 400A OCPD MS-ELA42) and to storage #S1030 (fed from100A OCPD MB - MS ELA33)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68055	18041-20000-45221	3305 W WOOD TER	90027	4	153A203   300	5434002007	R1-1	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Expired	05/20/2024 12:00:00 AM	ADDRESS	34.11227	-118.27781	Plan check for PV roof mounted and Energy Storage System, PV system size: 5.2kW with 16 PV Modules, 1 inverter(5.0kW) with 1 Tesla power wall 2.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68056	16041-30000-28581	2029 S CENTURY PARK EAST 15th FL-Lobby	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Issued	08/11/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in elevator lobby 15th floor in existing high-rise. Total lighting area: 340 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68057	14041-20000-23244	2934 N HOLLYRIDGE DR	90068	4	156A189   125	5583023012	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.12203	-118.32033	PV1Install roof-mounted solar array on SFD, interconnect with MSP.(2) ABB PVI-3000-OUTD-US-A transformerless inverter(26) Trina Solar TSM-245 PA05.05 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68058	15041-20000-18073	1014 E MANCHESTER AVE	90002	9	097-5A209 264	6042023030	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	PIN	33.9598697	-118.25710367	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes a new 2000-amp service, the installation of (16) panels, associated loads, a total indoor lighting area of 18,560 sq. ft. and an outdoor lighting area of 31,491. Note: Building permit is under application number 15016 - 10000 - 01400CHANGE OF USE  FROM AN EXISTING RETAIL, OFFICE, WAREHOUSE BUILDING TO 6 RETAIL SPACES AND 3 OFFICE/WAREHOUSE SPACES.  REMODELING IN AND OUTSIDE OF BLDG CHANGE FRONT ELEVATION; TENANT IMPROVEMENT AT 1 STORY RETAIL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68059	12041-20000-19889	5645 N LINDLEY AVE	91356	3	174B125   293	2157008072	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	02/24/2014 12:00:00 AM		Issued	02/24/2014 12:00:00 AM	ADDRESS	34.17359	-118.52746	Plan check for power only (no lighting). Senior Assisted Living, Occupancy is R 2.1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68060	19041-10000-27342	15146 W COVELLO ST	91405	6	186B145   279	2221003015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.20743	-118.46334	PV1. New LADWP Community Solar Program: 3.00KWdc / 2.40 kWac - 10 solar modules and 10 enphase IQ7-60-2 micro-inverters. Solar system is interconnected at existing service point of the single family home.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68061	14041-10000-08714	7330 N VARNA AVE	91605	2	186B157   452	2328028001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.2038	-118.42457	IN AN OFFICE BUILDING,REMOVE 400W HID LUMINAIRES AND REPLACE WITH 6-LAMPS LUMINAIRES FLUORSCENT; WIRING AND CONTROLS TO REMAINPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68062	14041-20000-13938	12411 W SHELDON ST #5A & 5B	91352	6	195B165   204	2629019015	(T)(Q)C1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	06/04/2014 12:00:00 AM	ADDRESS	34.23261	-118.40328	PLANCHECK FOR T24 ENERGY. VANILLA SHELL WORK FOR UNIT 5 SPLITTING INTO 5A  AND 5B. LIGHTING ONLY IN 5A. 655 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68063	15041-10000-39932	111 E UNIVERSAL HOLLYWOOD DR 23 RD FL	91608	4	162B177   624		C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	T24 OLNLY. T.I FOR A HIGH RISE BUILDING . TOTAL AREA 19178 SQ FT. 33TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68064	15041-10001-27726	714 N ISABEL ST	90065	1	145-5A219 333	5453027005	RD3-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			Reviewed by Supervisor	09/10/2015 12:00:00 AM	ADDRESS	34.09183	-118.22116	EXPEDITE per applicant(PV 2 roof mounted solar system, 2.385 KW PV array.(9) modules: KYOCERA #KU2656ZPA(1) INVERTER: PVI-3.0-OUTD-S-US*NOTE: multiple meters in the building.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68065	16041-10000-07981	13303 W RIVERSIDE DR	91423	4	168B157   293	2359019008	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	06/01/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.15778	-118.42318	FULL PLAN CHECK. CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE.. TOTAL  AREA 5566 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68066	17041-30001-06731	1217 S OCEAN FRONT WALK	90291	11	108A143   383	4226005004	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	33.98864	-118.47504	02-01-2018 Changes to an approved set of plan. Changes include re-configurate electrical equipment in electrical room. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68067	17041-20002-46290	6150 N LAUREL CANYON BLVD BLDG J	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	Changes to approved set.  Extensive SLD revisions and miscellaneous floor plan changes throughout.  Plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68068	17041-20000-31400	6001 N VAN NUYS BLVD	91401	6	177A151    92	2241027004	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM			Reviewed by Supervisor	10/25/2017 12:00:00 AM	ADDRESS	34.17961	-118.44899	New auto dealership with offices, showroom, service, and parking.  2000A 480Y/277V service.  Plan check for power and energy.  Building permit filed under 17010-20000-03375.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68069	17041-20000-46310	7454 N OAK PARK AVE	91406	6	186B133   495	2203023007	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.20634	-118.50493	PV1.  Install 4.493 kW roof mounted grid tied PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68070	17041-20000-44114	11749 N CHIMINEAS AVE	91326	12	216B125   312	2870019032	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.28453	-118.5333	PV1.  Install 13.2 kW roof mounted grid tied PV system.  (48) modules with (2) central inverters.$19.67 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68071	16041-10000-02243	5353 W PICO BLVD	90019	10	129B177   948	5085033017	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.04858	-118.35493	T-24, PC for energy only. TI to an existing commercial Building (Day care facility). Scope includes new lighting and receptacles for bathroom and classroom. Total affected area is 276 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68072	11041-20000-20673	35 E MARKET ST	90291	11	108A143   444	4226007023	CM-1	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	09/28/2011 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	ADDRESS	33.98792	-118.47362	energy plan check gallery and low voltage permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68073	14041-10004-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	33.95637	-118.3838	CHANGES TO APPROVED SET. CHANGES STILL ALL CLOUDED DELTA 6. UNDER THIS APPLICATION, CHANGE IS ONLY TO INCLUDE AN EXISTING 200A SERVICE TO 5000A TAP BOX. UPDATED LOAD CALCULATIONS AND FEEDER DIAGRAM PROVIDED. PC ONLY, PERMIT UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68074	14041-10000-30892	15747 W RAYEN ST	91343	12	195B141   297	2672008017	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.23204	-118.47559	PV 1  ROOF MOUNTED System size:7200W with (34) REC SOLAR: REC260PE(BLK) MODULES AND (1) POWER-ONE: PVI-3.6-OUTD-S-US-A(240V) INVERTER AND (1) POWER-ONE: PVI-3.6-OUTD-S-US-A (240V) INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68075	18041-10000-28687	926 N SYCAMORE AVE	90038	4	144B181   760	5532010047	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	02/10/2021 12:00:00 AM	ADDRESS	34.08796	-118.34265	Full plan check for a core and shell 8-story multimedia production building (parking at 2nd-5th floor, multimedia prodcution at 1st, 6th-8th floor) with a 3000-Amp 277/480v 3phase service/distribution board. This service is also supplying power to two other addresses in the same lot. New panels, new circuits, and new lights. Total area under the SOW: 203,851 sq.ft B#18010-10000-00248	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68076	14041-20000-14237	14520 W WILLOWGREEN LANE	91342	7	228B149   732	2502023***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.31933	-118.4518	Roof mounted PV system with transformerless inverter. PV system size 3.1KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68077	17041-20001-26323	16628 W KNAPP ST	91343	12	198B137   703	2687021011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.23822	-118.49484	Expedited plan check fee.  PV1.  Install 2.0 kW PV system with energy storage system.  (2) modules with 2kW rated inverter and battery system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68078	11041-10000-11260	642 S ALVARADO ST	90057	1	133-5A203 191	5141001904	C4-2	Central	Westlake			2089.03	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	06/10/2011 12:00:00 AM	ADDRESS	34.05819	-118.2755	T.I.  Existing Yoshinoya restaurant in a single story building.  Remodeling of light fixtures and enclosing patio to make it part of dining room.  Plan check is for Energy and Emergency lights only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68079	18041-20000-40705	649 N LAS CASAS AVE	90272	11	129B121   713	4415001021	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.04738	-118.54223	Installation of 26.4 kWh energy storage system connected to (E) PV system and associated distribution.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68080	19041-10000-35853	22248 W WYANDOTTE ST	91303	3	186B101   903	2023028013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.20272	-118.61201	[E-PLAN] NEW ESS(TESLA POWERWALL) CONNECTED TO EXISTING PV SYSTEM AND MAIN BREAKER DERATING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68081	15041-20000-02120	1573 W 46TH ST	90062	8	111B193   384	5016008018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.002	-118.30588	PV1. ROOFMOUNTED SOLAR SYSTEM. 4KW MICRO INVERTER(16) HYUNDAI HEAVY(16) ENPHASE M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68082	18041-10000-11274	361 N SALTAIR AVE	90049	11	135B141   155	4402016003	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM			PC Approved	08/01/2018 12:00:00 AM	ADDRESS	34.06878	-118.4747	NEW SINGLE FAMILY DWELLING W/BASEMENT AND ATTACHED GARAGE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68083	17041-10002-09030	505 N SILVER LAKE BLVD	90026	13	139-5A203 706	5401013010	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	Apartment			08/26/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	07/15/2022 12:00:00 AM	ADDRESS	34.078	-118.28001	Change to approved set of plans. All changes are clouded under delta 2. Changes include revising Service load calculations, single line diagram, emergency photometrics, and revising Title 24 calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68084	13041-10001-16308	201 WORLD WAY parking	90045	11	090B165    76	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	33.94469	-118.40336	PLAN CHECK ONLY. plan check fees on original application.][][] supplemental to existing work under 13041-10000-16308 (not yet approved) . supplemental is to account for the addition of lighting work in parking garage elevator and lighting upgrade. total projected area in new scope of work is 231,430 sq ft of illuminated area. Since the area is > 30,000 sq ft it could not be charged under submittal-2 fee under the original 10000-series application, which was marked over the counter. NOTE: SUBMITTAL-2 UNDER THIS PC # (13041-10001-16308) IS TO CHARGE FOR OUTDOOR LIGHTING AREA (2866 SQ FT) CHARGES THAT WAS NOT ACCOUNTED FOR IN SUBMITTAL FEE PERIOD ][][][PLAN CHECK FOR TITLE 24 PART 6 ENERGY. INDOOR AND OUTDOOR/FACADE LIGHITNG AT LAX. SCOPE OF WORK < 400A. ONE TOWER FOUR FLOORS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68085	18041-10000-18636	5932 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	33.94435	-118.38715	TENANT IMPROVEMENT AT EXISTING SECOND FLOOR TO BUILD-OUT NEW (3) NEW TRAINING ROOMS; SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2514.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68086	19041-20000-06809	9400 S LA TIJERA BLVD PV1	90045	11	096B161   831	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	08/29/2020 12:00:00 AM	ADDRESS	33.95618	-118.4163	PV2.  Install 162.43 kW DC / 148.42 kW AC roof mounted grid tied PV system.  (445) modules with (4) 33.3 kW rated string inverters and (1) 20 kW rated string inverter. System 1 of 4.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68087	11041-10000-11950	340-350 S MAIN ST	90291	11	109-5A143  79	4286004009	M1-1	West Los Angeles	Venice	Venice		2734.00	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	07/19/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	33.99519	-118.47673	New Fire Alarm for the new Google campus in Venice, CA.  Site has 3 buildings with the following addresses:  321 S. Hampton Dr, 340 S. Main St, and 350 S. Main St.  340 S. Main St and 350 S. Main St are connected and are the buildings submitted under this application.  The application for 321 S. Hampton Dr is to be submitted under a different application.  This application also includes the parking garage that is attached to  340 S. Main St.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68088	13041-10000-01634	1910 W SUNSET BLVD	90026	13	139-5A207  72	5404001040	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.20	Electrical	Electrical	Commercial			01/22/2013 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.0779	-118.26081	T24 for church. 1545 sqrfeet. low rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68089	17041-10000-24919	3418 W 6TH ST	90020	10	135B197  1014	5502028009	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			07/24/2017 12:00:00 AM			PC Info Complete	07/26/2017 12:00:00 AM	ADDRESS	34.06343	-118.29611	PC for T24 for new lighting for change of use TI. Total affected area is 3875 sqft.  Installing two new panels, one AC unit, one new 400A service. Building 17041-10000-02969.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68090	11041-20000-08125	100 W 5TH ST	90731	15	018B201   822	7455027933	PF-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	33.74066	-118.28033	Root mount P.V. with 142.08 KW for Port of L.A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68091	18041-10000-11731	835 W BLOOM WALK 2nd floor	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM			PC Info Complete	04/02/2018 12:00:00 AM	ADDRESS	34.01948	-118.2876	PC for energy only for demo and remodel of existing office space. Installing two new panels, lights, receptacles and equipment. Total area 4041sqft. B#18016-10000-08509.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68092	13041-10000-09449	11537 N VIKING AVE	91326	12	213B121   337	2871005006	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.28123	-118.54587	PV1 2 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 5.635 KW. TRANSFORMERLESS. 23 MODULES AND 1 INVERTER. [INVERTER: POWER ONE AURORA PVI-4.2-OUTD-S-US] [PV MODULE: TRINA SOLAR TSM-245PC05/PA05.18].	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68093	14041-20000-26858	7081 N SALE AVE	91307	12	183B097   870	2024041034	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.19887	-118.61822	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING 25 MODULES. USING TRANSFORMERLESS INVERTER. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68094	16041-10001-28829	3500 W 6TH ST #226	90020	10	135B197  1016	5502030016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM			PC Approved	09/07/2016 12:00:00 AM	ADDRESS	34.06346	-118.29849	FULL PC PER INSPECTOR REQUEST. POWER PC. - ENERGY PC ALREADY UNDER APPLICATION 16041-10000-26269	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68095	12041-10000-21910	224 W 1ST ST	90012	14	130-5A213   7	5149001007	C2-4D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Info Complete	09/14/2012 12:00:00 AM	ADDRESS	34.05321	-118.2452	TI IN AN EXISTING COMMERCIAL BUILDING, ON THE SECOND FLOOR OF THE LA TIMES WEST BUILDING. CIRCUITS HAVE BEEN REVISED. THE TOTAL LOAD TO THE SERVICE HAS BEEN REDUCED.  PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68096	15041-20001-28031	1638 E VERNON AVE	90011	9	112-5A213  86	5106003025	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2015 12:00:00 AM			PC Approved	09/25/2015 12:00:00 AM	ADDRESS	34.00372	-118.24454	Expedited per applicant request.Plan check for a PV1 roof-mounted PS system. Systems size is 5 kWac and consists of (1) inverter, (24) modules, and (24) power optimizers. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68097	15041-20000-05624	14823 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.17768	-118.45525	Title 24 plan check only.  Total area = 40,725 sq. ft. (hardscape)Installation of new outdoor lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68098	10041-10000-25398	22566 W VANOWEN ST	91307	3	180B097    26	2038027029	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	12/22/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.19355	-118.61896	New fire alarm.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68099	17041-20000-08951	6420 W WILSHIRE BLVD 1250	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for energy only. TI to office suite 1250 on 12th floor of existing high rise office building. New lighting (incl. emergency). 4,285sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68100	15041-10001-35554	515 S FLOWER ST 52 FLR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	ADDRESS	34.05134	-118.25661	RECHECK APPROVED SET OF PLANS. PER CUSOTOMER, BREAKER SIZES REPLACED LIKE FOR LIKE. - PC FOR NEW AVAILABLE FAULT CURRENT LEVELS AT NEW DISTRIBUTION BOARDS. NO OTHER CHANGES. CLOUDED NOTES DELTA 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68101	18041-20000-30156	4658 N LONGRIDGE AVE	91423	4	168B157   544	2360025021	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.15559	-118.42124	PV1.  Install 15.435 kW roof mounted grid tied PV system.  (49) modules with 7.6 and 5.0 kW rated string inverters.  System split between main house and detached structure.  Derating of main disconnect.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68102	15041-20000-26830	17238 W RINALDI ST	91344	12	213B133   692	2697001014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	02/27/2016 12:00:00 AM	ADDRESS	34.27914	-118.50918	PV1 SFD TOTAL SYSTEM SIZE 5KW USING SINGLE INVERTER SYSTEM. USING STANDARD PLAN. TOTAL OF 23 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68103	19041-20000-53932	1041 S ABBOT KINNEY BLVD	90291	11	108B145   972	4239021020	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	33.99209	-118.47107	Plan check for Title 24 Energy only, new lighting in the space. Total area; 633 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68104	16041-10000-31946	3534 W SUNSET BLVD	90026	13	144A203   167	5427025008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.08937	-118.27692	TI new small restaurant 641 sr	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68105	16041-10000-29980	3324 W WILSHIRE BLVD 1-17	90010	10	132B197    46	5094007021	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			08/23/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.06151	-118.29488	NEW FIRE ALARM SYSTEM WITH 162 FA DEVICES AND 3 COMMUNICATION AND ONE FA PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68106	19041-10000-00991	615 S SPRING ST	90014	14	129A211   246	5144002016	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.04565	-118.25147	PLAN CHECK FOR TITLE 24 ONLY FOR - Change of Use from Retail to Restaurant (110' x 19') - TOTAL AFFECTED AREA = 1850 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68107	15041-10000-19560	928 S BROADWAY	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	ADDRESS	34.04154	-118.25658	NEW FIRE ALARM SYSTEM TO A HIGH RISE BUILDING, 11 FLOORS. TOTAL FIRE ALARM DEVICES: 1774 AND 1 FIRE ALARM PANEL . note: verify for power supply for final approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68108	12041-20000-13219	7624 N VARNA AVE	91605	2	186B157   106	2303006014	CM-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/07/2012 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.20931	-118.4246	Service upgrade to 400A for place of assembly building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68109	15041-20000-08541	300 N VIA NICOLAS	90272	11	126B117   124	4416002015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Expired	03/12/2018 12:00:00 AM	ADDRESS	34.044	-118.55426	Plan check for power. Project work includes the installation of a new 600-amp service, (6) panels, and associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68110	16041-20000-42707	14333 W ROSCOE BLVD	91402	6	192B149   362	2638026001	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Apartment			12/06/2016 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.22177	-118.44569	NEW 4 STORY 46 UNITS APARTMENT BUILDING.  1600 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68111	12041-20000-14612	2959 S CRENSHAW BLVD	90016	10	120B185   316	5050018009	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.02787	-118.33529	T.I. to a donut shop.  Install general/emergency light.  Plan check for energy only.Note: Permit issued under 11041-10000-06342	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68112	19041-10000-45118	4201 W WILSHIRE BLVD SUITE 204	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	34.06189	-118.31911	T-24 ENERGY PC FOR AN EXSTING SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES AND TRANSFORMER. TOTAL AFFECTED AREA 4155sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68113	14041-10000-32466	376 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	33.93089	-118.26675	Per�Senate�Bill�No.1222, Fee cap reached, thus fee is $0.PV2, INSTALL  15.68 KW DC ROOF-MOUNTED SOLAR ARRAY ON A COMERCIAL  BUILDING. INTERCONNECT WITH MAIN SERVICE PANEL. 6 STRINGS.(2) INVERTERS:  DELTA-SOLIVIA 7.6TL (56) MODULES: LDK SOLAR LDK-280P-24	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68114	18041-20002-21729	20059 W RINALDI ST	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.2756	-118.57118	Plan check for lost set of previously approved plans.  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is a first-time tenant to a movie theater. Total lighting area = 38,400 sq. ft.Note: Building application has been generated under 18016-20000-18638)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68115	14041-20000-33064	16509 W SHAMHART DR	91344	12	216B137   335	2609030026	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2014 12:00:00 AM	12/26/2014 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.28723	-118.49139	pv1install roof mounted pv system sized 6.0kw interconnected with msp.(27) canadian solar cs6p-250p modules(1) solaredge se6000 tr inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68116	14041-10001-14260	425 W 11TH ST	90015	14	127-5A207 254	5139008010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM	ADDRESS	34.04208	-118.26257	CHANGES TO PERMITTED SET OF PLANS: LUMINAIRES WATTAGES ARE CHANGED BUT DESIGNATIONS REMAINED THE SAME; CHANGES ARE CLOUDED(((((Core and shell only - office building renovation of an existing building (levels 1-5) with a new level (level 6)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68117	14041-10005-34554	4091 S REDWOOD AVE 1-67	90292	11	108B153   893	4230006032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			11/01/2016 12:00:00 AM			PC Approved	11/01/2016 12:00:00 AM	PIN	33.99096225	-118.44116852	11/01/2016 Changes to an approved set of plans. Changes include replace 4 Fluorescent  lighting fixtures with 14 new LED in Rec Room. Changes apply to Delta 1 only. {{{{{Power plan check for new 5 story 67 unit apartment building. Two new 2000 A services.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68118	14041-10001-17169	1602 N ELEVADO ST	90026	13	144A205   434	5425005019	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM			PC Approved	07/15/2014 12:00:00 AM	ADDRESS	34.08719	-118.27326	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 10.965 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OTIMIZERS.(43) MODULES: TRINA SOLAR TSM255PA05.18(2) TRANSFORMERLESS INVERTERS: SOLAREDGE SE5000A-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68119	13041-10000-14057	11186 W CHALON ROAD	90049	5	141B145   231	4369010001	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.08188	-118.46048	PV1.  Roof-mounted 7 KW DC solar array, interconnect into existing main service panel.  {28 modules: CS6P 250P}  {central inverter: Fronius IG-PLUS 7.5-1 UNI}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68120	13041-20000-09531	7920 N CHASTAIN AVE	91335	3	189B129   695	2101029004	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Expired	05/21/2015 12:00:00 AM	ADDRESS	34.21425	-118.52365	SOLAR SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68121	15041-20000-39987	1627 S PANDORA AVE	90024	5	132B157   454	4326030026	R1-1-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.05883	-118.42617	PV1. Install roof mounted PV system sized 5 kW. Interconnectd with main service panel.(19) SunEdison 325W Modules(19) SolarEdge Power Optimizers(1) Solar Edge SE5000A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68122	15041-10000-04270	7401 WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	33.94379	-118.42359	Title 24 plan check only.  Total area = 25,200 sq. ft.Installation of 2 new light poles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68123	19041-20001-24735	6600 N TOPANGA CANYON BLVD 1100	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK ONLY FOR CHANGES TO SPPROVED STE, SCOPE OF WORK IS TO MATCH AS BUILT ON FIELD. SCOPE OF WORK INCLUDES REVISING THE RUN LENGTH OF A FEEDER. ALL CHANGES ARE CLOUDED UNDER DELTA 20.ORGINAL SCOPE:((plan check for a convenience store located inside Westfield Mall. Scope includes new lighting and equipment with a total area of 1,919-SQ FT.  2 feeders 225A each 3ph,3wBld: 19016-10000-00085 ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68124	18041-20000-07423	15721 W COBALT ST #120	91342	7	222B141   334	2604009***	(T)(Q)RD6-1-K	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.30373	-118.47353	PV1.  Install 4.2 kW roof mounted PV system.  (14) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68125	17041-10000-28268	9333 N MELVIN AVE	91324	12	198B117   121	2761036046	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.24024	-118.56026	T. I. TO (E) WAREHOUSE WITH INCIDENTAL OFFICE.new panels with new connected load over 400 A. total sq. ft 24,365	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68126	14041-10000-17419	1644 S BENTLEY AVE 1-9	90025	5	129B153   667	4324032009	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.04864	-118.44372	NEW FIRE ALARM SYSTEM FOR 5 STORY APARTMENT BUILDING. 64 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68127	10041-10000-18021	810-812 N CROFT AVE	90069	5	141B173   153	5529003019	[Q]R3-1	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Apartment			09/13/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	03/30/2012 12:00:00 AM	ADDRESS	34.08572	-118.37409	NEW 4-STORY 6 UNITS APARTMENT W/ BASEMENT GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68128	11041-10001-10748	1900 S SEPULVEDA BLVD	90025	5	126B153   181	4323022031	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM	10/06/2011 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.04447	-118.4413	Brand New Fire Alarm System in an existing shell building for Animanl Hospital.  3 stories tall with 3 story parking garage.  Everything is new.   Fire Alarm has been seperated from Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68129	18041-10000-43860	4700 W COLORADO BLVD	90039	13	162B205   119	5593018906	PF-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Info Complete	10/24/2019 12:00:00 AM	ADDRESS	34.13942	-118.27536	NEW 1200A DISTRIBUTION  BOARD WITH A VOLTAGE CLASS OF 480Y/277V CONNECTED TO A TRANSFORMER RATED AT 225 KVA, WITH NEW PANEL BOARDS, INVERTER, 20HP ELEVATOR, AS WELL AS A  800A DISTRIBUTION BOARD WITH A VOLTAGE CLASS RATING OF 208Y/277 ALL FED BY AN EXISTING SERVICE OF 3000A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68130	12041-10001-30654	380 W WORLD WAY #T57	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	Supplemental power plan check for space T57 which is a first-time tenant.  (((T.I.  Remodel for airport concession space # T57.  Plan check is for Title 24 only using the area category.  Applicant wanted to have the T-24 plan check as back room.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68131	17041-10000-24725	7520 S BROADWAY	90003	9	099B201    48	6031011039	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	33.97113	-118.2781	Plan check for T24 only, remove outdoor HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68132	14041-20001-34874	11826 W PALMS BLVD	90066	11	117B153   987	4249018022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			PC Approved	12/29/2014 12:00:00 AM	ADDRESS	34.0141	-118.43272	EXPEDITED PER CUSTOMER REQUEST.PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 10 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (40) SOLAR WORLD SW270 MONO MODULES(1) SOLAR EDGE 10,000A-US INVERTER(40) SOLAR EDGE P300 SOLAR OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68133	16041-20000-06351	1445 S SPAULDING AVE	90019	10	129B177   798	5069010026	R2-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	04/08/2016 12:00:00 AM	ADDRESS	34.04943	-118.36298	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.1 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68134	16041-10000-23679	1025 S ALVARADO ST	90006	1	130-5A201 218	5136013006	C2-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	11/08/2016 12:00:00 AM	ADDRESS	34.05114	-118.28045	T-24, PC FOR ENERGY ONLY. NEW 2 STORY OFFICE BUILDING, NEW LIGHTS, RECEPTACLES, AND NEW PANELS. TOTAL AFFECTED AREA IS 7195 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68135	11041-10000-17821	6120 N LINDLEY AVE BLDG 1	91335	5	177B125   657	2123024025	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	34.1812	-118.52711	change of use from SFD to classroomsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68136	14041-20000-23872	1813 W 51ST ST	90062	8	111B193  1251	5015007020	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Expired	09/29/2016 12:00:00 AM	ADDRESS	33.99705	-118.31178	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(12) SOLAR WORLD PLUS SW270 MODULES(12) SOLAR EDGE P300 POWER OPTIMIZERS(1) SOLAR EDGE SE3800 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68137	10041-20000-21070	1535 S WESTERN AVE Suite I-J	90019	10	126B193   196	5073011028	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.01	Electrical	Electrical	Commercial			10/22/2010 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	03/01/2011 12:00:00 AM	PIN	34.04434704	-118.30937491	Plan check power and energy for T.I. for a dental suite (Dental Western). Existing panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68138	11041-10000-17036	1861 N GAFFEY ST	90731	15	024B197    78	7442022021	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM			PC Approved	10/06/2011 12:00:00 AM	ADDRESS	33.76188	-118.29325	TI TO A BEAUTY SALON.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68139	16041-10001-12510	1177 E 21ST ST	90011	9	120A211   109	5131009036	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM			PC Approved	07/11/2016 12:00:00 AM	ADDRESS	34.02365	-118.25347	Original plan is Lost, this is Plan Check only as a replacement, system size and design remain the same. Permit under the Master PCIS#<<PV1 rooftop solar installation on Duplex SFD, 2.15 kW AC.     (12) MODULES-Hyundai HiS-M250MG      (12)MICROINVERTERS-ENPHASE M215-60-2LL-S2X-IG>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68140	13041-10000-30827	18452 W HALSTED ST	91325	12	201B125   466		(T)(Q)R3-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Public Safety Only			11/05/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.24439	-118.53563	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68141	13041-20000-16267	1441 W OLYMPIC BLVD	90015	1	129A205    54	5137006025	C2-1	Central	Westlake	Westlake South		2100.10	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.04841	-118.27203	"NEW PV SYSTEM WITH INTEGRAL ISOLATION TRANSFORMERS. LAW SCHOOL. ROOF MOUNTED. FOR THIS APPLICATION(1 OF 3) SYSTEM SIZE IS 12KW. PV MODULES LOCATED ON THE ""BURNS BUILDING"" TOTAL OF 60 MODULES. SINGLE SET OF PLANS HAVE BEEN SUBMITTED. ASSIGN ALL THREE APPLICATIONS TOGETHER. BUILDING CONTAINS SEPARATE SERVICE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68142	16041-20001-35652	7975 W WOODROW WILSON DR	90046	4	156B173   363	5570022001	RE11-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2016 12:00:00 AM			PC Approved	10/18/2016 12:00:00 AM	ADDRESS	34.12302	-118.37118	VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68143	16041-10000-13868	7758 N DENSMORE AVE	91406	6	189B141   228	2206011033	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	PIN	34.21184784	-118.47652327	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM EXISTING RESTAURANT TENANT SPACE TO A COMMISSARY.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1564 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68144	19041-10000-23997	232 E 2ND ST E	90012	14	129A213    28	5161024034		Central				2062.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	04/24/2020 12:00:00 AM	ADDRESS	34.0495	-118.24258	T-24 PLAN CHECK FOR TI (Change of use from Retail to Restaurant). SCOPE INCLUDES NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTL AFFECTED AREA IS 3381 SQ.FTNew Connected load less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68145	14041-10000-00339	1333 N SAN PABLO ST	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.06159	-118.20463	PLANCHECK FOR T24 ENERGY. LOAD < 400 AMPS. BIOMECHANICS INJURY RESEARCH LAB. 863 SQFT, EMERGENCY LIGHTING. NO SURGICAL PROCEDURE PERFORMED PER APPLICANT. PROJECTED AREA OF WORK IS APPROX. 863 SQ FT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68146	16041-10000-21568	10000 S VERMONT AVE	90044	8	091-5A199 131	6054009029	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			06/20/2016 12:00:00 AM	07/05/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	33.94531	-118.29139	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 600A 120/208 3PHASE 4WIRE SERVICE, A NEW 800A 120/208 3 PHASE 4 WIRE DISTRIBUTION BOARD, AND NEW SUBPANELS FOR A NEW 7 ELEVEN CONVENIENCE STORE. TOTAL AFFECTED AREA IS 20624 SQ. FT.  B#16041-10000-02671	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68147	17041-10001-02221	3111 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.02983	-118.37395	T-24, PC For energy only. TI to an existing commercial office building. Scope includes new lights and receptacles. Total affected area is 5985 Sq. Ft. b#16016-10000-25334Note: Permit is paid under PCIS#17041-90000-02221	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68148	15041-10000-06428	5425 N DENNY AVE	91601	2	174B177  1017	2416016030	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.16924	-118.36472	PC FOR POWER AND ENERGY. NEW 8-UNITS, 2-STORY APARTMENT BUILDING ON GRADE LEVEL .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68149	14041-20000-32211	15830 W LIGGETT ST	91343	12	198B141   363	2671032016	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	12/23/2014 12:00:00 AM	ADDRESS	34.23999	-118.4775	PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING 2 CENTRAL INVERTERS. TRANSFORMERLESS TYPE. SYSTEM IS A LINE SIDE CONNECTION. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68150	19041-10000-48169	6260 N GENTRY AVE	91606	2	177B165   153	2334009047	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.18465	-118.3931	[EPLAN] NEW PV1 ROOF-MOUNTED INSTALLATION WITH A SYSTEM SIZE OF 3.78KW DC/ 3.8KW AC, 12 MODULES (HANWHA Q-CELLS 315W), 12 POWER OPTIMIZERS (SOLAREDGE P400), 1 CENTRAL INVERTER (SE3800H), 1 ESS (TESLA POWERWALL) , 1 LOAD CENTER RATED AT 125A WITH AN EXISTING 200A SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68151	14041-20000-12297	9245 N BURNET AVE	91343	7	198B145   248	2656020019	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Apartment			05/08/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.23853	-118.46338	Brand new 2-story 9-unit apartment building. Plan check for Power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68152	13041-20000-33724	817 W 112TH ST	90044	8	087A199    56	6075008021	R1-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2412.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	01/15/2014 12:00:00 AM	ADDRESS	33.93348	-118.28923	New rooftop PV System for an existing sfr.  System is UNGROUNDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68153	19041-20000-08366	6322 N FALLBROOK AVE	91367	3	177B097    15	2039020012	(Q)C2-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Issued	03/28/2019 12:00:00 AM	ADDRESS	34.18527	-118.62312	PLAN CHECK FOR POWER AND TITLE 24 ENERGY  FOR EXISTING COMMERCIAL INDOOR NURSERY PLAN/RETAIL, TOTAL LOAD EXCEED 400A TOTAL SQUARE FOOTAGE = 342 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68154	15041-10000-38165	21850 W OXNARD ST	91367	3	177B105    80	2146006045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.17895	-118.60413	EXPANSION + RENOVATION OF EXISTING STARBUCKS INSIDE MARRIOT HOTELPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68155	10041-10000-09798	380 W WORLD WAY temp dock-bridge	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM			PC Approved	06/25/2010 12:00:00 AM	PIN	33.94094587	-118.40577128	T-24 and emergency lighting plan check for a canopy connecting loading dock to the existing north exit stair at the TBIT.  It is about 275 feet long.  Not for public use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68156	18041-20000-04554	10301 W WASHINGTON BLVD	90232	5	117B165   165	4208005013	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	05/17/2018 12:00:00 AM	ADDRESS	34.0195	-118.40141	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,106 sq. ft.Note: Building applications has been generated under 17016-70000/70001/70002-10405.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68157	13041-10000-02500	430 W 6TH ST	90731	15	015B201    89	7455004005	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Closed	02/27/2015 12:00:00 AM	ADDRESS	33.73887	-118.28643	PLAN CHECK POWER AND ENERGY FOR  MARYMOUNT COLLEGE. THE NEW 800A SERVICE AND DISTRIBUTION BOARD APPROVED UNDER #12041-10000-17109. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68158	12041-10000-14379	10707 W ASHBY AVE	90064	5	126B157  1229	4255023020	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2012 12:00:00 AM	08/06/2012 12:00:00 AM		Permit Finaled	10/29/2012 12:00:00 AM	ADDRESS	34.03796	-118.42246	"Plan check for new rooftop pv system for a single family dwelling.  7.14kw DC.  Plan check is only for PV System, service and panel upgrade are not part of this plan review.  Fees, including service upgrade, are under ""INPSECTION""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68159	13041-10000-35565	1333 S HOPE ST	90015	14	126A207   195	5134011009	[Q]R5-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Info Complete	06/05/2015 12:00:00 AM	ADDRESS	34.03867	-118.26646	PLAN CHECK FOR POWER AND ENERGY FOR NEW 6 STORY , 33-UNIT APARTMENT COMPLEX AND COMMERICAL. MIXED USE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68160	13041-10000-09983	2000 S AVENUE OF THE STARS 12th floor	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM			PC Approved	04/17/2013 12:00:00 AM	ADDRESS	34.05868	-118.41546	T24 PLAN CHECK FOR EXISTING OFFICE SPACE. SCOPE OF WORK IS ON THE 12TH FLOOR. 6970 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68161	13041-10002-35598	11985 W BLUFF CREEK DR BLDG #3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	Changes to approved set.  Additional 15 HP elevator motor, (2) water heaters, additional ckts, some revised loads, additional areas added to scope of Title 24 outdoor lighting.  (((CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  35,665 SF WITH NEW SURFACE PARKING LOT. 3 TOTAL BUILDINGS.  THIS IS BUILDING 3/5 IN THE SAME PARCEL. TITLE 24 ENERGY FEE CHARGED UNDER THIS BUILDING. METHANE ZONE. BDLG PERMIT: 13110-10000-04243)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68162	16041-10000-30601	1149 S LOS ANGELES ST	90015	14	126A209   302	5139016018	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.03729	-118.25832	Full PC for power and energy. Change of use from Warehouse to Retail located on methane zone. Scope includes a new 800A 120/240V 3 phase 4wire service/distribution board, new subpanels, new motors, and new lights. Total affected area is 28710 Sq. Ft. B#16016-10000-14983	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68163	16041-10000-45766	380 WORLD WAY Gateway	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for power and Title-24.  Provide normal and emergency power to LAX MSC gateway building.Building permit #16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68164	12041-10000-04692	4400 W SUNSET BLVD	90027	13	147A201   164	5542010040	C2-1D	Central	Hollywood	East Hollywood		1913.00, 1953.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	07/30/2012 12:00:00 AM		Permit Finaled	12/10/2012 12:00:00 AM	ADDRESS	34.09662	-118.28529	PLAN CHECK FOR AN OFFICE BUILDING. TI OFFICE RENOVATION. 40,000 SQ FT. SINGLE STORY. T24 EMERGENCY LIGHTING, POWER INCLUDED. FIRE ALARM VARIANCE ISSUED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68165	17041-20000-42487	11860 1/2 N BALBOA BLVD	91344	12	216B133   474	2610002048	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	34.2858	-118.50159	ti to an existing commercial space.  addding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68166	15041-10001-06395	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	CHANGES TO AN APPROVED SET, NOTE DELTA 1. REMOVING TWO LIGHITNG FIXTURES AND ADDING NEW LIGHTING FIXTURES IN THE RESTROOM. (((T24 FOR EXISTING RESTAURANT SPACE 2528 SQRFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68167	17041-10000-32966	11911 W CULVER BLVD	90066	11	111B161  1140	4233020003	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Expired	06/20/2019 12:00:00 AM	ADDRESS	33.99617	-118.41724	"PC for new rooftop PV and battery system. Installing 21 modules with optimizer, one 9.8 KWh battery, 7.6kW inverter amd new sub panel.CEIS 747978""COMPLY WITH DEPARTMENT ORDER effective date01/12/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68168	18041-10000-48970	725 W MANCHESTER AVE	90044	8	097-5A201 244	6032015048	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.96022	-118.28627	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68169	16041-20000-24576	18115 W TOPHAM ST	91335	3	177B125  1046	2124015052	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.1811	-118.52795	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:3.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68170	18041-10000-02090	7366 N HAYVENHURST AVE	91406	6	186B137   238	2226001907	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20377	-118.49397	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68171	14041-10000-00492	1300 S SAN PEDRO ST STE #119	90021	14	123A211    69	5132019001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	04/14/2014 12:00:00 AM	PIN	34.03251075	-118.25377188	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 765 SQ FT. REPLACING TOTAL OF 3 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68172	16041-10000-02230	4925 W ADAMS BLVD	90016	10	123B181   977	5049001042	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.03269	-118.34787	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (DAYCARE FACILITY). SCOPE INCLUDES NEW LIGHTING FOR THE BATHROOM. TOTAL AREA IS 47 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68173	19041-20000-45397	10110 N BREIDT AVE	91042	7	204B201  1196	2570003030	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1013.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.25186	-118.27387	PV1.  Install 4.62 kW roof mounted grid tied PV system.  (14) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68174	12041-10000-09340	1891 N GAFFEY ST #B	90731	15	024B197    78	7442022021	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM			PC Approved	05/18/2012 12:00:00 AM	ADDRESS	33.76247	-118.29335	New medical chiropractic office in an existing single story commercial building.  Full plan check for power and energy requested by applicant.  Plan Check ONLY. Suppl. Permit was issued under 12041-40001-07708.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68175	14041-20000-35190	1762 E 92ND ST	90002	15	094-5A213 140	6048032016	C2-1VL	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	33.95313	-118.2413	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:4 KW. MICROINVERTER NON STANDARD PLAN.(16) HYUNDAI HIS M250(16) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68176	18041-20000-21846	4529 N SHERMAN OAKS AVE	91403	5	168B145  1010	2283017006	C1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			Reviewed by Supervisor	06/28/2018 12:00:00 AM	ADDRESS	34.15316	-118.46943	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement and office addition. Work includes a 600-amp service and a total lighting area of 24,468 sq. ft.Note: Building application has been generated under 16016-20000-27915	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68177	10041-20000-11897	1714 N MCCADDEN PL	90028	13	148-5A185  86	5547010011	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Apartment			06/22/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	10/26/2010 12:00:00 AM	ADDRESS	34.1021	-118.3373	revision to approved plans	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68178	18041-20000-28490	12310 W HAMMACK ST	90230	11	105B161   597	4220011008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	33.98453	-118.41169	Plan check for PV roof mounted system, system size: 4.8kW AC with 15 PV Modules and 15 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68179	14041-20000-10947	5065 N ALHAMA DR	91364	3	171B105  1128	2167007021	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.16136	-118.59337	PV1.  Install 4.75 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68180	15041-10000-28938	14749 W VINCENNES ST	91402	6	198B149   175	2650030006	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	34.24038	-118.45553	PV1 roof mouted systen for a single family home . Scope of work: (64) modules, (4) inverters: 20 kw (total), load center: 125 amps. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68181	17041-10000-19981	11500 W OLYMPIC BLVD STE 150	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.03624	-118.44415	PC FOR POWER AND ENERGY FOR A TI DUE TO CHANGE TO *MEDICAL OFFICE*  WITH EXAM ROOMS AND OPERTATION ROOM.TOTAL AFFECTED AREA 5912 SF.BL# 17016-10000-16019	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68182	15041-10000-16665	903 S NEW HAMPSHIRE AVE 1-16	90006	10	132B197   786	5094025002	(T)(Q)R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			06/01/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.05572	-118.29316	NEW FIRE ALARM SYSTEM 100 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68183	10041-20000-17114	501 E VERNON AVE	90011	9	112-5A207  40	5113014801	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM	01/14/2011 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.00403	-118.26639	Plan check for power only. Installation of 2500A section, panel, equipment, and ckts to existing 2500A service and switchboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68184	14041-20000-13756	3006 N ARROWHEAD DR	90068	4	156B185   112	5577035049	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.12372	-118.3284	(($0 permit fee due to senate bill 1222 from 2012)))PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.9KW INTERCONNECTED WITH MAIN PANEL.(53) MODULES ET SOLAR ET-P660245BB(2) TRANSFORMERLESS POWER-ONE  PVI-6000-OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68185	19041-20001-02412	8537 N LOUISE AVE	91325	12	192B133    58	2787025003	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.22589	-118.51	EXPEDITE PER APPLICANT REQUEST<<<<<<<NEW ROOFTOP SOLAR SYSTEM CONSIST OF 49 MODULES (Type :LG 335N1C-AS 335W), 49 OPTIMIZER (Type : SE P400) AND 2 CENTRAL INVERTER/S (Type :SE7600H-US each). SYSTEM SIZE IS 16.42KWdc and 15.2KWac.>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68186	16041-10000-35138	333 S HOPE ST STE 3700	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.05326	-118.25292	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR SUITE 3700. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 5911 SQ. FT. B#16016-10000-23624	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68187	19041-10001-07345	21045 W OSBORNE ST	91304	3	195B105    41	2779048009	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM			PC Approved	06/24/2019 12:00:00 AM	ADDRESS	34.23322	-118.59228	Changes to approved set, all changes are under delta 3. Scope of work incldues adding fixture types and deleting fixture types. pc ONLYOriginal Scope of work((TI IN AN EXISTING COMMERCIAL SPACE. INSTALL NEW LIGHTS.13,099 SQR FT. T-24 ENERGY ONLY.BUILDING PERMIT: 19016-10000-03172))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68188	19041-20000-01445	9839 W BURGEN AVE	90034	11	123B165   348	4311002022	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.03489	-118.39977	Installation of (2) tesla battery back up (ESS) 5 kWh each to an existing PV system.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68189	19041-10000-14101	1580 W FRANCISCO ST PV-1	90501	15	057B193    31	7351021037	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	06/04/2020 12:00:00 AM		Permit Finaled	03/02/2022 12:00:00 AM	ADDRESS	33.8493	-118.30699	$0 fees due per AB 1414. PV2. NEW ROOFTOP SOLAR SYSTEM ON A COMMERCIAL BUILDING. SCOPE INCLUDES 3411 MODULES (Q-PEAK 395), 1706 OPTIMIZERS (P850 ) AND 10 INVERTERS ( SE 99.9K). SYSTEM SIZE IS 999.99KWac AND 1347KWdc	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68190	15041-20000-32663	6143 W ELEANOR AVE	90038	13	144B189   740	5534022020	R3-1XL	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			10/02/2015 12:00:00 AM			Reviewed by Supervisor	10/30/2015 12:00:00 AM	ADDRESS	34.08994	-118.32588	New 8 unit apartment building. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68191	12041-10000-03205	13003 W VAN NUYS BLVD	91331	7	210B161   568	2534015030	[Q]C2-1VL-CDO	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	04/30/2012 12:00:00 AM		Permit Finaled	06/26/2012 12:00:00 AM	ADDRESS	34.27051	-118.41658	NEW 7/11 STORE.  (CHANGED FROM 99C ONLY).  EXISTING SERVICE. NEW PANELS & CIRCUITS. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68192	14041-20000-24915	7014 S HOOVER ST UNIT 7	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 7.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68193	19041-10001-53403	3400 S FIGUEROA ST	90007	9	120A203   222	5123022040	USC-1B	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Approved	02/14/2020 12:00:00 AM	ADDRESS	34.02167	-118.2799	EXPEDITE FEENEW ROOF MOUNTED PV INSTALLATION WITH A SYSTEM SIZE OF 619.36 KW DC/ 62.5KW AC, TAPPED TO EXISTING SWITCHGEAR RATED FOR 1200A, 8 CENTRAL INVERTERS (SUNNY TRIPOWER CORE 62-US), 98 MODULES (P-19 400),  AND 1000 A BUS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68194	10041-10000-00792	5652 N VINELAND AVE 1st  floor	91601	4	174B173   697	2415005033	C4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			01/15/2010 12:00:00 AM	08/02/2010 12:00:00 AM		Permit Finaled	08/04/2010 12:00:00 AM	ADDRESS	34.17366	-118.36994	TI - existing building - elderly daycare commercial kitchen area remodel - Permit is for new ckts, equipment on existing panel.  P/C is for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68195	16041-10003-40590	11058 W CHANDLER BLVD BLDG 1	91601	2	171B173  1406	2350014015	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM			PC Approved	11/05/2019 12:00:00 AM	ADDRESS	34.168	-118.37216	CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON CLOUDED AREAS DELTA 'RFI 239'. CHANGES INCLUDE THE REVISION OF FEEDERS ONLY, VOLTAGE DROP AND FAULT CURRENT. _PLAN CHECK ONLY______________________________________________________________________Supplemental PC for changes to approved set. Changes include new lights, receptacales, panels, equipment  removal of fire pump, addition of electrical room and addition of transformer disconnects. All changes clouded under delta 1,2,3,4,5.This is plan check only! Permit for scope to be collected under 10002	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68196	19041-10000-22741	835 W ROSECRANS AVE	90247	15	075B197   209	6119015016	[Q]C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.90207	-118.29068	Replacing Existing HID Fixtures with new LED Fixtures (Outdoor). Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68197	19041-10000-23957	1926 E 7TH PL	90021	14	124-5A217 332	5166017005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.03343	-118.23298	NEW FIRE ALARM FOR CHANGE OF OCCUPANCY FROM WAREHOUSE TO THEATRE. SCOPE INCLUDES NEW FA PANEL WITH 33 DEVICES, ANNUNCIATOR AND VOICE EVAC COMMUNICATION SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68198	19041-10000-49496	1300 S SAN PEDRO ST STE 125	90015	14	123A211    69	5132019001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.03256	-118.25392	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68199	14041-10001-05419	301 E FLORENCE AVE	90003	9	102B205   798	6011008030	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM			PC Approved	08/29/2014 12:00:00 AM	ADDRESS	33.97488	-118.269	Applicant added a new 150KVA transformer between service and main distribution panel to convert from 120/240 to 120/208  volt from an approved set.(((TI for a new 7 Eleven retail store in an existing shell retail building.  New 600A rated service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68200	16041-20000-19993	5555 W MELROSE AVE 1ST FLOOR	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.08363	-118.32191	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR 1ST FLOOR OFFICES AND STORAGE.  6675 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68201	10041-20001-20464	11540 N SEPULVEDA BLVD	91345	7	213B145     9	2664006***	A2-1, RE20-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM			PC Info Complete	02/03/2011 12:00:00 AM	ADDRESS	34.27973	-118.4687	Changes from previously approved plans.  Changes in general lighting.  Plan check for energy only.*****PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR INTERIOR REMODEL.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68202	17041-10000-33813	1024 S PACIFIC AVE	90731	15	015B197  1190	7456001027	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	33.73459	-118.28774	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68203	14041-10000-25074	2717 W OLYMPIC BLVD 101-201	90006	10	129B197   181	5078009029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	34.05281	-118.29223	plan check for title 24 on coffee shop TI. total area is 980 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68204	18041-10000-45660	11907 W WICKS ST	91352	6	198B169   179	2631004017	(T)(Q)M1-1-CUGU, (T)(Q)P-1-CUGU, [Q]M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.23496	-118.39267	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68205	19041-10000-28614	1300 W EXPOSITION BLVD	90018	8	117B193   653	5036001004	C2-2D-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	07/18/2020 12:00:00 AM	ADDRESS	34.01803	-118.30043	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68206	18041-10000-41319	2240 W FAIR PARK AVE	90041	14	160-5A221  18	5686020017	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Issued	11/05/2018 12:00:00 AM	ADDRESS	34.13621	-118.21645	Plan check for outdoor lighting only (T24 only), no structural TI per applicant. Replace existing exterios lights with new LED lights. Total area: 36,539 sq.ft	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68207	13041-10000-10112	12412 W BLUFF CREEK DR BLDG 18	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	33.97709	-118.40692	New fire alarm system for a new single-story commercial bldg.  1 central panel and remote annunciator, and 39 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68208	18041-10000-12414	16207 W ROSCOE BLVD	91343	12	192B137   300	2689004023	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Issued	04/06/2018 12:00:00 AM	ADDRESS	34.22149	-118.48553	REMOVE OUTDOOR METAL HALIDE FIXTURE AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68209	11041-20000-25567	9315 S FIRTH BLVD	90002	15	094-5A211 106	6048001026	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			12/01/2011 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	33.95174	-118.24769	New 50.74 KW roof mounted PV system on the roof of  a 3 story apartment building.  The inverters and AC components of the system are to be installed in the electrical room located in the garage area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68210	10041-10000-03075	10700 W WILSHIRE BLVD	90024	5	132B153  1095	4330015***	[Q]R5-3-O	West Los Angeles	Westwood			2656.00	Electrical	Electrical	Apartment			02/22/2010 12:00:00 AM	02/22/2010 12:00:00 AM		Permit Finaled	03/23/2010 12:00:00 AM	ADDRESS	34.06061	-118.43591	Install indoor general lighting in fitness room.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68211	18041-20002-24233	21300 W HART ST	91303	3	183B105   690	2138016015	MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM			PC Approved	11/05/2019 12:00:00 AM	ADDRESS	34.19728	-118.59574	11/5/19CHANGES TO APPROVED SET DELTA 1 ONLY CHANGES TO FUSIBLE AC DISCONNECT AND ADD PERFORMANCE METER.<<<PV2.  Install 20 kW roof mounted grid-tied PV system. (68) modules with (2) 10kW rated string inverters.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68212	10041-10000-18251	9232 N ETON AVE	91311	12	198B105   101	2746010010	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			09/15/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	03/08/2011 12:00:00 AM	ADDRESS	34.23886	-118.59443	TI IN AN EXISTING OFFICE BUILDING CHANGED TO A MEDICAL LABORATORY. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68213	15041-10000-14912	5420 N YOLANDA AVE	91356	3	174B121   813	2161026004	(Q)C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			05/15/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.16939	-118.54034	FIRE ALARM FOR NEW 57 UNIT APARTMENT BUILDING. 245 DEVICES AND 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68214	11041-10000-12902	10250 W SANTA MONICA BLVD # 133	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	08/22/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IMPROVEMENT AT A RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68215	13041-20001-29086	9145 N DEERING AVE	91311	12	198B105   159	2746010030	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			PC Approved	12/31/2013 12:00:00 AM	ADDRESS	34.237	-118.59622		N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68216	19041-10000-18030	13040 N SAN FERNANDO ROAD STE B	91342	7	222B145    62	2501006024	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.30749	-118.46881	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68217	17041-20001-06994	10244 N CANDLEBERRY LANE	91324	12	204B121   168	2729027037	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM			PC Approved	03/13/2017 12:00:00 AM	ADDRESS	34.25671	-118.55074	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (44) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68218	14041-10000-24452	1758 S CARMONA AVE	90019	10	126B177   682	5064009005	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.0422	-118.3603	PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(24) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68219	17041-10001-08868	457-465 W 7TH ST	90731	15	015B201   179	7455006006	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Closed	04/20/2021 12:00:00 AM	ADDRESS	33.73769	-118.28698	"DELTA ""5"" changes to approved plans. changes to T-24, adding emergency lights and new circuts.(((FULL PC FOR POWER AND ENERGY TI TO (E) TWO STORY RESTAURANT. CHANGE OF USE OF (E) TELEPHONE CENTER INTO RESTAURANT. SCOPE INCLUDES A NEW 800A 120/240V 3 PHASE, 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 7211 SQ. FT.)))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68220	18041-10000-43380	12280 W MONTAGUE ST	91331	7	204B165   203	2537018022	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Issued	02/21/2019 12:00:00 AM	ADDRESS	34.25522	-118.40059	NOTE: PLANS ARE MISSING PANEL SCHEDULES. PLANS ARE INCOMPLETE. VERIFY BEFORE TAKING PLANS IN. FEE ESTIMATE ONLY. FULL PC FOR POWER AND ENERGY. CONVERT (E)  ELECTRO PLATING MANUFACTURER BUILDING TO (N) HYDROPONIC AGRICULTURAL ENTERPRISE. SCOPE INCLUDES A NEW 4000A SERVICE/DISTRIBUTION BOARD, NEW  PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 12080 SQ. FT. B#18016-10000-31816	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68221	19041-20000-43607	10934 N CARTWRIGHT DR	91311	12	210B113   263	2708030026	(Q)RA-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.26959	-118.56622	Plan check for PV roof mounted system, PV system size: 6.30KW with 18 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68222	12041-10000-21413	3400 W 6TH ST # 301	90005	10	135B197  1012	5502028018	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			09/10/2012 12:00:00 AM	10/19/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	PIN	34.06339483	-118.29573965	TENANT IMPROVEMENT IN RETAIL STOREPLAN CHK  IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68223	17041-20000-21270	16081 COLUMBUS LN	91343	12	192B141   234	2673019073	(T)(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM				pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68224	17041-10000-10932	5913 W FRANKLIN AVE	90028	4	150A191   170	5586014054	C1-1D	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.1054	-118.31884	Title 24 plan check.  Change of use from retail to take out restaurant.  Existing 200 amp subpanel to remain with new lighting and equipment loads.  Total area = 1,110 sq. ft. (indoor) + 140 sq. ft. (outdoor)     Building permit #16016-10000-28139	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68225	19041-10000-50996	1138 W 68TH ST	90044	8	102B197   524	6014022006	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	08/13/2020 12:00:00 AM	ADDRESS	33.97773	-118.29499	PV-1 plan check, system size 5.440KW. 17 modules(LG320N1K-V5) with optimizers (solaredge P320) and 1 inverter (SE3800H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68226	13041-10000-00398	2403-2407 W 4TH ST	90057	1	135A203   203	5154035003	R3-1	Central	Westlake		YES	2088.02	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.06409	-118.27662	"NEW BUILDING METHANE MITIGATION FOR BLDG A & B with common underground Parking garage.see 12010-10000-01750 and 01751. New 25 and 14-senior-apartment-units over garage (garage provides parking for Buildings A and B).""COMPLY WITH DEPARTMENT ORDER effective date 11/07/2005. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68227	12041-20000-08769	7405 W PYRAMID PL	90068	4	156B177   455	2427014026	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	PIN	34.1225914	-118.35630387	Install roof mounted PV system and change the service main circuit breaker to 150 amperes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68228	14041-10000-34969	833 E 3RD ST	90012	14	129A215   259	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	PIN	34.04615917	-118.23530019	Installation of new fire alarm system for a core and shell project in existing commercial space.  Total system size = 32 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68229	14041-10000-12964	1235 E VIENNA WAY	90291	11	111B149   596	4242013006	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.0007	-118.4541	$O PERMIT FEE PER SENATE BILL #1222.PV1, INSTALL 18.87 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTERS AND WITH OPTIMIZER.                                            $0 permit fee is due to the 2012 Senate Bill No.1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68230	11041-10000-05415	1800 E 50TH ST	90058	9	111A213   212	5106027007	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			03/18/2011 12:00:00 AM			Corrections Issued	03/26/2011 12:00:00 AM	ADDRESS	33.99794	-118.24282	"Manufacturing spaces (6) there is an order to comply for work done with no permit.  Panels are added to services.  Single line need to reflect the addition rather than ""E"" status.  this paln is for the sub panels and title 24.  No building permit involved yet."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68231	09041-10001-23815	128 E 6TH ST	90014	14	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/04/2010 12:00:00 AM			PC Approved	02/11/2010 12:00:00 AM	ADDRESS	34.04472	-118.24949	Plan check only. Remodel of existing space in high rise building.  First tenant for an adaptive reuse.  Power only.  T-24 checked under 09041-10000-23815.  Applicant provided note on plan to indicate that the space does not require emergency lighting based on communication with fire department.  The exit sign shown on the plan is existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68232	13041-10000-02973	2792 N CASIANO ROAD	90077	5	156B145    84	4378029003	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2013 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.12595	-118.471	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY 2 STORY DWELLING. TOTAL SYSTEM SIZE 13.44KW. USING 56 PANELS AND CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68233	19041-20000-13446	4520 N VAN NUYS BLVD	91403	4	168A151   188	2265013025	C2-1VL-RIO, P-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Issued	07/09/2019 12:00:00 AM	ADDRESS	34.15371	-118.4485	Plan check for Title 24 only. Project site is an existing commercial building (grocery store). Project scope is a tenant improvement. Total lighting area = 33,999 sq. ft.Note: Building application has been generated under 19016-20000-10687. Electrical scope of work is limited to areas noted on floor plans. Title 24 square footage includes all areas of the floor, including those which have existing to remain lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68234	14041-20001-02150	4934 N LOUISE AVE	91316	5	168B133   119	2289008015	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.15952	-118.50964	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 8.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68235	15041-20000-17251	8516 N MARKLEIN AVE	91343	6	192B145   169	2654019005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.22523	-118.47076	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (29) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68236	14041-10001-18601	10777 W WILSHIRE BLVD	90024	5	132B153   173	4360004012	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			08/19/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.06038	-118.43901	08/19/16 Plan check for power and energy high-rise appartment . Changes to an approved set of plans. Changes include change lighting fixtures in appartment untis & commom corridor area, add emergency lighting fixtures down light fixtures in commom corridor area, add cooking equipment & warmer drawer load in each unit, and down size the Emergency Generator from 300kW to 200kW. Changes apply to delta 4 only************Peevious work description.***********************************PC FOR  POWER AND ENERGY. New 56-unit, 5-story Type IIIA over 2-story Type IA residential/parking with 2 levels of subterrean parking garage. (100% submittal/PDPP>PERMIT IS GOING TO BE UNDER NEC 2008 AND CEC 2008.BUILDING APP#; 13010-10000-03895.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68237	18041-10000-45671	5400 W 104TH ST	90045	11	090B173   305	4129035001	M2-1	West Los Angeles	Westchester - Playa del Rey			2780.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.94082	-118.37431	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68238	18041-10001-09523	7425 W SUNSET BLVD	90046	4	147B181  1131	5550013004	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Closed	05/01/2019 12:00:00 AM	ADDRESS	34.09818	-118.35187	PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR A TEMPORARY SALES TENT. TOTAL AFFECTED AREA IS 2622 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68239	16041-10000-08351	524 E WASHINGTON BLVD	90015	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Issued	04/06/2016 12:00:00 AM	ADDRESS	34.0283	-118.25963	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS(1294) MODULES-ECOSOLARGY ECO310H156P-72 (11)INVERTERS-SOLAREDGE SE33.3K(647)OPTIMIZERS-SOLAREDGE P700Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68240	19041-10000-47505	1015 S WALL ST	90015	14	126A211   424	5145019027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.03739	-118.25362	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68241	18041-10000-15973	1243 N GOWER ST	90038	13	144B189   189	5534004010	R3-1	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Apartment			05/01/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	09/24/2021 12:00:00 AM	ADDRESS	34.09376	-118.32251	NEW 4 STORY, 5 UNIT APARTMENT BUILDING WITH A 600 AMP SERVICE.BUILDING PERMIT #: 17010-10000-03250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68242	13041-20000-03189	1121 N AVALON BLVD	90744	15	033B205   754	7420021021	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	04/17/2013 12:00:00 AM		Permit Finaled	09/17/2013 12:00:00 AM	ADDRESS	33.78539	-118.26305	Commercial photovoltaic system on roof YMCA center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68243	15041-20000-21612	5400 N BALBOA BLVD #321	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	PIN	34.16914714	-118.50029545	Plan check for Change of use from Medical office to Medical Clinic with 4 exam rooms. Total indoor lighting area: 2,604sqftNote: Building plan check has been filed under application 15016-20000-13341	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68244	12041-10000-26479	11216 W EXPOSITION BOULEVARD S/R	90064	5	123B153   276	4256011902	[Q]PF-1XL	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	01/25/2013 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	PIN	34.03456305	-118.43511483	New 3 level parking structure. New service, panel, and circuits. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68245	17041-20000-12003	450 S OXFORD AVE	90020	10	135B193   611	5503013022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.06562	-118.30766	PV2.  Install roof mounted PV system sized 30kw interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68246	16041-30000-37299	8738 N TAMPA AVE	91324	12	195B117   134	2784003058	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			10/20/2016 12:00:00 AM			PC Approved	10/25/2016 12:00:00 AM	ADDRESS	34.22934	-118.55337	Title 24 plan check.  T.I. to existing commerical building.  New lighting in retail, dressing room, office, and storage areas.  Total area = 4,129 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68247	17041-20000-20186	1726 N NORTH SPRING ST Unit 1	90012	1	136-5A219  47	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.06983	-118.2261	service upgrade to an existing commercial building 600 amps.  Plan check for power and energy. First time tenant - Interior remodel to office and add a mezzanine. T24 area - 5,409sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68248	13041-20004-35618	12015 W BLUFF CREEK DR BLDG 2	90094	11	105B165   922	4211011038	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	33.98173	-118.4029	PC FOR CHANGES TO APPROVED SET. CHECKING NEW AIC RATINGS AND FAULT VALUES DUE TO CHANGE IN CONDUCTOR TYPE. CHECKING NEW RATINGS AT VFD AND RELOCATION OF SITE LIGHITNG CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68249	18041-20000-29476	15233 W VENTURA BLVD 605-610	91403	4	168B145   898	2264007020	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Issued	08/06/2018 12:00:00 AM	ADDRESS	34.1538	-118.46502	ti to an existing commercial building.  adding new lighting new controls to existing panels plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68250	19041-10000-24568	13069 W SHENLEY ST	91342	7	228B161   477	2511031005	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Issued	06/26/2019 12:00:00 AM	ADDRESS	34.32102	-118.41798	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 16 MODULES (Q-PEAKG4.1 305), OPTIMIZERS (SE P320) AND A CENTRAL INVERTER (SE5000H-US). SYSTEM SIZE IS 4.88KWdc AND 5KWac. SERVICE PANEL UPGREADED TO 125A. NO SERVICE UPGRADE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68251	16041-20000-45349	9045 W ORIOLE WAY	90069	4	147B169   770	5560004013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.09694	-118.38765	pv1addition to an existing pv system.  installing roof mounted pv system sized 7.6kw iterconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68252	19041-20000-17494	10323 N SYLVIA AVE	91326	12	204B117   135	2728009025	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.25796	-118.55263	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM. SYSTEM SIZE IS 10.8KW DC/9.45KW AC. SCOPE OF WORK INCLUDES (30) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS, AND A NEW 100A SOLAR SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68253	14041-10003-32210	117 S BOYLE AVE	90033	14	129A221   232	5174013905	C2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			12/02/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Closed	09/21/2017 12:00:00 AM	ADDRESS	34.04687	-118.22011	12/02/2016 Changes to an approved set of plan. Changes include additional circuits in DAS Electricla room and dedicate circuit for MSO. Changes apply to delta 8 only{{{{{{Full plan check for new appartment(4 stories) with partial first floor commercial(core and shell for commercial first floor).  Service size 2,500 Amps. Note: Variance to seperate fire alarm has been filed (11/19/2014)}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68254	18041-10000-34803	521 N ROCKINGHAM AVE	90049	11	135B137   472	4406004001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	04/03/2019 12:00:00 AM	ADDRESS	34.06464	-118.49068	0.00 fee due to senate bill 12222NEW 13.98 KW ROOF MOUNTED PV SYSTEM WITH 43 PV PANELS AND 54 KWH ENERGY STORAGE SYSTEM CONNECTED TO THE EXISTING 600 AMP SERVICE ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68255	14041-10000-32182	7450 N WISCASSET DR	91307	12	186B085   157	2017036018	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM			Verifications in Progress	03/03/2015 12:00:00 AM	PIN	34.20786502	-118.65907977	PV1.  Install 8.8 kW DC ground-mounted, utility-interactive PV system.  Enphase M250 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68256	14041-10000-17235	2970 N RIPPLE PL	90039	13	151-5A211 312	5442031043	(T)(Q)CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			06/26/2014 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.10734	-118.24886	NEW FIRE ALARM FOR A NEW APARTMENT BUILDING.56 UNITS.  TOTAL # OF DEVICES 272 AND 1 PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68257	17041-20000-38384	20750 W LASSEN ST	91311	12	201B109   118	2748004034	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.24984	-118.5859	PV2.  Install roof mounted grid tied PV system sized 77kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68258	10041-10000-16831	3455 S OVERLAND AVE	90034	5	120B161   672	4254026006	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM			PC Approved	08/25/2010 12:00:00 AM	ADDRESS	34.02511	-118.41213	TI in an existing area. Plan Check is for Title 24 and emergency lighting one story restuarant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68259	14041-20000-01688	5867 S CENTRAL AVE SUITE 210	90001	9	105B209   588	6007005020	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	33.98775	-118.25672	TI FOR NEW DENTAL OFFICE ON AN EXISTING SERVICE. FIRST TIME TENANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68260	19041-10000-35379	2913 W EXPOSITION PL Units 5	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02048	-118.32811	Plan check for a PV2 2.56kw DC / 3.0KW AC roofmounted system. Scope includes (8) modules and (1) inverter interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68261	18041-10000-34956	648 E FLORENCE AVE	90001	9	102B205   836	6023001010	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	11/17/2020 12:00:00 AM		Permit Finaled	06/07/2024 12:00:00 AM	ADDRESS	33.97458	-118.26328	PC FOR ENERGY ONLY, REMODEL AND 2 STORY ADDITION OF (E) ONE STORY OFFICE BUILDING AND SITE PARKING. SCOPE OF WORK INCLUDES NEW 400AMP SERVICE, LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 8660 OUTDOOR AND 1825 INDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68262	17041-20000-23795	6240 N FULTON AVE	91401	2	177B157   232	2331002052	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Apartment			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.18424	-118.42235	Plan check for fire alarm only. New fire alarm system for 3-story, 18-unit apartment building. 1FACP. 100 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68263	15041-20000-04088	748 E 9TH ST	90021	14	124-5A211 109	5132002038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.03603	-118.24932	Plan check for power only. Remove existing 600A service distribution equipment. Install new 600A service in a new electrical room, reconnect existing panels, motors, and loads to new service distribution. New service drop location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68264	17041-20001-12471	12200 W OLYMPIC BLVD STE 300	90064	11	123B149   602	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	06/26/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.03195	-118.45506	"PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT ON THE 3RD FLOOR OF EXISTING COMMERCIAL BUILDING "" RIOT GAMES"". NEWLY CONNECTED LOAD EXCEEDS 400 AMPS.  PLAN CHECK FOR POWER AND ENERGY.BUILDING APPLICATION WAS GENERATED FOR BOTH THE 3RD AND 4TH FLOOR TI UNDER APPLICATION NUMBER 17016-10000-04530."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68265	19041-10000-01360	11950 W FOOTHILL BLVD	91342	7	210B165   148	2532012041	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.2757	-118.3967	PC FA FOR  fitness center (gym).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68266	16041-20000-25117	1015 S FAIRFAX AVE	90019	10	132B177   710	5086001004	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			07/18/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.05765	-118.36427	Plan check for energy only. Change of use from commercial retail to food prep. New lighting (incl. emergency) and receptacles. 3,194sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68267	17041-10000-36794	819 N POINSETTIA PL	90046	5	141B181   174	5526007031	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Public Safety Only			10/12/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.08581	-118.34878	Installing a commercial fire warning system in a large SFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68268	14041-10000-12963	2215 N VERMONT AVE	90027	4	153B197   663	5588016044	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.11184	-118.29212	PV1, INSTALL 14.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTERS AND WITH OPTIMIZER.       $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68269	14041-20000-25933	21115 W DUMETZ ROAD	91364	3	168B105   324	2167012026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.15853	-118.59271	$0 permit fee is due to Senate Bill SB-1222.  PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 15KW INTERCONNECTED WITH MSP.(40) SUNPOWER SPR-E20-327 MODULES(3) POWERONE INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68270	15041-30001-37304	3516 S SAWTELLE BLVD	90066	11	117B157   438	4249032045	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Apartment			11/05/2015 12:00:00 AM			PC Approved	12/24/2015 12:00:00 AM	ADDRESS	34.0163	-118.42336	Expedite fees only.     Installation of new roof mounted solar PV array on existing apartment building.  Total system size = 38.5 kWac.  System consists of 5 7.7 kWac inverter with 27 modules each.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68271	18041-10002-14172	9101 W LA TUNA CANYON ROAD	91352	7	198B185   199	2545024008	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2018 12:00:00 AM			PC Approved	09/21/2018 12:00:00 AM	ADDRESS	34.23661	-118.33153	DELTA 1 CHANGES TO APPROVED PLANS FOR A CHANGE OF LAYOUT OF THE LOCATION OF PV PANELS ON THE ROOF BECAUSE OF EXISTING OBSTRUCTIONS. PLAN CHECK ONLY.<<<PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM. SYSTEM SIZE: 34.3 KWdc / 27.4KWac(98) ENPHASE IQ6PLUS-72-2-US(98) SOLARWORLD SW350XL MONO>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68272	15041-10000-04201	1500 S BEVERLY DR	90035	5	129B165   261	4306015027	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			02/11/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	01/04/2018 12:00:00 AM	ADDRESS	34.05226	-118.39516	Plan check for power and energy. Project is a new 8-unit apartment building. Project scope is a new 800-amp service and 800-amp rated MSB, (9) panels and associated loads. Approved for submittal by F.Y.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68273	17041-30000-45533	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	33.94502	-118.40714	Plan check for power and energy. Project site is LAX Terminal 3. Project scope is a tenant improvement to areas on the 3rd and 4th floors. Total lighting area = 3,557 sq. ft.Note: Building appication has been generated under 17016-10000-37633	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68274	19041-20000-01987	21800 W BURBANK BLVD Ste 200	91367	3	174B105    42	2146007122	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.17267	-118.60262	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68275	19041-20000-29290	6109 N MELVIN AVE pv1	91356	3	177B117   519	2153023008	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.1812	-118.56028	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.DC rating 16KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68276	18041-20000-16264	13610 W EMELITA ST	91401	2	174B157   123	2343004005	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.1765	-118.4291	Plan check for a PV1 roof-mounted PV system. System size is 11.16 kWac-CEC/12.16 kWdc with and  inverter size of 11.4 kWac and consists of (1) inverter and (32) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68277	14041-20000-17413	1940 CENTURY PARK EAST 4TH FLOOR	90067										Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM				TIPLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING ONLY.  EXISTING HIGH RISE BUILDING ALL CIRCUITS ARE EXISTING.  WORK TO BE DONE ON THE FOURTH FLOOR ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68278	10041-10000-00538	142 W SANTA CRUZ ST	90731	15	018B201   573	7449014020	R4-1XL	Harbor	San Pedro	Central San Pedro	YES	2962.10	Electrical	Electrical	Apartment			08/09/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	09/08/2011 12:00:00 AM	ADDRESS	33.74429	-118.28107	NEW 49 UNITS APARTMENT BUILDING WITH UNDER GROUND GARAGEVARIANCE TO SPARATE THE FA PLANS WAS FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68279	17041-20000-07990	6105 N ELLENVIEW AVE	91367	3	177B085   250	2032016009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.18155	-118.65971	pv1install roof mounted pv system sized 5.7kw interconnected with msp. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68280	17041-20000-34733	6320 N CANOGA AVE SUITE 950	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.18499	-118.59722	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. HIGH RISE.  124 SQFT. SUITE 950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68281	18041-10001-38071	11100 W SANTA MONICA BLVD 8TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.04726	-118.44465	SUPPLEMENTAL FOR CHANGES TO APPROVED SET. CHANGES INCLUDE CHANGE TO LIGHT FIXTURE QUANTITY AND LOCATIONS. DELTA 3 CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68282	11041-10000-11408	7101 W MELROSE AVE	90046	5	141B181   591	5525009024	C4-1VL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	05/15/2012 12:00:00 AM	ADDRESS	34.08357	-118.34448	CHANGE OF USE FROM A FLOWER SHOP TO A RESTAURANT (NEW OCCUPANCY).  PLAN CHECK FOR ENGERGY AND POWER.  FIRE ALARM TO SUBMITTED SEPERATELY.      CONTACT NUMBER 818.995.8952 EXT 22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68283	14041-20000-33584	14315 W VALERIO ST	91405	2	186B153   369	2215024015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2014 12:00:00 AM	12/04/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.20493	-118.44503	pv1. roofmounted solar system. 3.92 negativeley grounded system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68284	14041-10001-02369	8631 N ROSLYNDALE AVE	91331	6	192B157    47	2627026002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.2268	-118.42033	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS INVERTER WITH OPTOMIZERS. SYSTEM SIZE: 4 KW. TWO STORY HOUSE.(16) TRINA SOLAR #TSM-250(16) SOLAREDGE OP300 OPTOMIZERS(1) SOLAR EDGE #SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68285	18041-10000-19380	1237 S RIMPAU BLVD	90019	10	129B185   384	5083016009	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.05174	-118.33603	"PC FOR NEW ""ESS"" IN SFD. SCOPE INCLUDES INSTALLATION OF NEW TESLA POWER WALL HOUSE HAS EXISTING PV  SYSTEM. TOTAL SYSTEM SIZE 5.00KW-AC"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68286	13041-10000-05240	12648 W RYE ST	91604	2	165B161   214	2362015017	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2013 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.15119	-118.40916	on the roof of a SFD, installation of a 4.752KW pv system using microinverters	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68287	12041-20000-16193	5855 W VENICE BLVD	90019	10	126B173   558	5069005019	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM			PC Approved	07/12/2012 12:00:00 AM	ADDRESS	34.04178	-118.36689	T-214 lighting plan check for alteration to interior lighting and new exterior lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68288	14041-10000-24007	888 S FIGUEROA ST SUITE 170	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.0465	-118.26225	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SHOWROOM IN A HIGHRISE. SUITE 170.  476 SQFT.""COMPLY WITH DEPARTMENT ORDER effective date01/10/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68289	15041-10000-07093	368 N LA CIENEGA BLVD	90048	5	138B173   106	5514012001	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	34.07799	-118.37639	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 2025 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68290	14041-10000-33452	12054 N MONOGRAM AVE	91344	12	216B137   172	2609028033	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.28949	-118.49085	PV 1 ROOF MOUNTED WITH SYSTEM SIZE: 6KW AND 1 INVERTER AND 18 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68291	19041-10000-33227	12822 W HIGHWOOD ST	90049	11	132B137   328	4406009022	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM			Reviewed by Supervisor	09/04/2019 12:00:00 AM	ADDRESS	34.05822	-118.48971	NEW ROOF MOUNTED 29.5KW PV SYSTEM WITH 82 PV PANELS AND OPTIMIZER AND 3 CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68292	13041-10004-30473	1891 N ACADEMY DR	90026	1	141B213    20	5415005902	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.08305	-118.2417	INSTALL NEW PANEL TO FEED JOCKEY PUMP AND CISTERN PUMP SEPERATELY.  MODIFICATION TO FIRE PUMP COMPARTMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68293	13041-20001-24116	23031 W SYLVAN ST	91367	3	177B097    93	2039011003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.18476	-118.62891	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING 24 MODULES. 3 STRINGS. ON 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68294	11041-20000-19814	10011 W CHEVIOT DR	90064	5	123B165   225	4316015006	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2011 12:00:00 AM	10/05/2011 12:00:00 AM		Permit Finaled	01/09/2012 12:00:00 AM	ADDRESS	34.03578	-118.40305	Plan check new installation roof mounted 6.45KW photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68295	16041-10000-34118	959 N SEWARD ST 4TH FLOOR	90038	4	144B185   969	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.08878	-118.33338	Full plan check for a 1st time tenant T.I; Scope include new lighting, receptacles, (4) panel and other equipment. Total area for the energy plan check is 15,645 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68296	13041-20000-34658	3867 N CORBIN AVE	91356	3	162B117   237	2180019006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.14012	-118.56443	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.3 KW AC USING MICROINVERTER ENPHASE M215 STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68297	19041-20000-33091	6514 N ALDEA AVE	91406	6	180B133   345	2230022014	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Issued	09/30/2019 12:00:00 AM	ADDRESS	34.18905	-118.5078	PV1. INSTALL 12.285 KW DC ROOF MOUNTED PV SYSTEM.  39 MODULES WITH 7.6 AND 5.2 KW RATED INVERTERS, AND 40.5 KWH ENERGY STORAGE SYSTEM.  $0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68298	15041-10000-32955	420 E 3RD ST STE-120	90013	14	129A213   235	5147006011	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/05/2015 12:00:00 AM	01/07/2016 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.04686	-118.24182	Full plan check for a new OSHPD-3 ( DIALYSIS CLINIC) T.I; Scope includes (5) new panels, lighting, circuits, and equipment.  Building permit is under I-Occ. load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68299	13041-10000-32088	250 S HARBOR BLVD	90731	15	018B201   796	7440030***	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	33.74182	-118.27938	New electrical service and distribution equipment for USS Iowa in Port of Los Angeles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68300	18041-10000-14855	209 N WESTERN AVE	90004	4	138B193   731	5517004022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2115.00	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.07499	-118.30934	PLAN CHECK  FOR T24 ONLY, CHANGE OF USE FROM RETAIL TO RESTAURANT. INSTALL (1) 100A NEW PANEL FOR NEW LOADS/CIRCUITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68301	18041-20000-48748	8218 N WILKINSON AVE	91605	2	192B165   630	2308020004	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.22051	-118.40401	permit fees $0.00 by state senate bill no.1222pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.(2) tesla 5KWh batteries	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68302	19041-20000-31295	839 S FEDORA ST	90005	10	132B197   762	5094017019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			08/20/2019 12:00:00 AM	02/18/2020 12:00:00 AM		Permit Finaled	08/12/2022 12:00:00 AM	ADDRESS	34.05655	-118.29781	Plan check for 2500A 208Y/120V 3ph-4w service.  Plan check for power and energy.  Building permit filed under 18010-10000-00377.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68303	13041-20000-26908	1000 W WILSHIRE BLVD SUITE 2100	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.05085	-118.26078	PC FOR T24 ENERGY ONLY. SMALL OFFICE REMODEL. WORK DONE IN SUITE 2100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68304	16041-20000-36518	1311 W SEPULVEDA BLVD	90501	15	045B193   791	7347018097	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Apartment			10/14/2016 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	33.81492	-118.30044	Plan check for a fire alarm system for a new 6-story apartment building. System consists of (1) FACP, (1) annunciator, and (691) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68305	15041-20001-34050	9250 N RESEDA BLVD STE 8	91324	12	198B125   208	2764012014	P-1VL, QC4-1VL, QP-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.23857	-118.53589	12/24/15Changes to an approved set.Scope includes relocating existing panels to new location and removing some lighting fixtures. PC for Disaggregation of electrical circuits.((((Title 24, plan check energy only. T.I. to existing restaraunt space.  New lighting, recepticles, cooking equipment, and HVAC.  Existing 400 A service to remain. Total area = 3,331 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68306	14041-20000-24916	7014 S HOOVER ST UNIT 8	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97563	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 8.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68307	19041-10000-17346	12530 W HESBY ST	91607	2	171B161   993	2357008031	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.1618	-118.40639	[ePlan] New 7.6 kW AC rooftop solar on (E) SFD. Install  (27) roof mounted PV solar panels, (1) 7.6 kW inverter,  (27) P400 optomizers. System connect to 200A MSP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68308	11041-10000-14587	1112 E 12TH ST	90021	14	123A211   229	5132016044	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM			Corrections Issued	04/06/2012 12:00:00 AM	ADDRESS	34.03084	-118.24749	UPGRADE SERVICE TO 600A AND SPLIT A WAREHOUSE INTO 5 NEW RETAIL UNITS WITH SUB-PANELS.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68309	13041-10000-26097	3760 N BALLINA CANYON ROAD	91436	5	162B137   411	2286009033	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.13899	-118.49057	PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING TO MAIN PANEL. SYSTEM SIZE 8.25 KW DC IN A 2-STORY HOUSE. WORK IS DONE ON CENTRAL INVERTER STANDARD PLAN. 3 TOTAL STRINGS; 3 STRINGS WILL BE COMBINED @ INVERTER, NOT COMBINER BOX.  (33)MODULES: TRINA SOLAR #TSM-250PA05.18(1)INVERTER: FRONIUS # IG PLUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68310	14041-10000-09659	1803 E SLAUSON AVE	90058	9	108B213   730	5105023015	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	33.98964	-118.24084	T24 only. Remove HID light fixtures and replace with new fluorescent fixtures. Total area 1653 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68311	18041-10001-07858	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	Change to approved set by adding (50) devices on the floor plan. New devices are added throughout most of the ckts on the floor plan, and most of the calculation shall be rechecked. All changes under delta-2 and 3 only.Original plan checker, Mehdi.(((Install New Fire alarm system on New 8 story hotel (note** plan check engineer to verify w/ number of story under 17010-10000-03362 and 16041-20000-44615), scope consists of (10) FA panels, and (707) devices.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68312	14041-20000-18082	10449 N MEMORY PARK AVE	91345	7	207B145   718	2649021002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM			PC Approved	07/03/2014 12:00:00 AM	ADDRESS	34.26055	-118.46421	PV1.  Install 4.5 kW roof-mounted utility-interactive PV system.   (21) Microinverters and modules based on the previous aproval plan with permit #14041-20000-13744.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68313	11041-10000-19692	16200 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM			PC Approved	12/30/2011 12:00:00 AM	ADDRESS	34.21558	-118.48784	T-24 and emergency lighting plan check for remolded space in building. INTERIOR REMODEL OF EXISTING ONE-STORY DEMISED TENANT SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68314	18041-10000-15482	9020 S BELLANCA AVE	90045	11	093B169    25	4125010013	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	33.95455	-118.38038	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68315	16041-10000-11402	18334 W MALDEN ST	91325	12	192B125   203	2786007004	(T)(Q)R3-1, R1-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Apartment			04/01/2016 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	PIN	34.22512205	-118.53292311	"PROPOSED 22-UNIT  4-STORY APT.  BLDG.,  WITH 1-LEVEL SUBTER. PRIVATE PKG.  GARAGE.""2-VERY LOW INCOM UNITS.""                                                                                                                                PC FOR POWER AND ENERGY. DUE TO BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 ENERGY STANDARDS.F.A variance is submitted on 4/1/16"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68316	16041-10000-16780	3031 W BEVERLY BLVD	90026	13	138A201   257	5156011020	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	PIN	34.07185532	-118.28149145	REMODEL (E) 1ST FLOOR CHILDCARE FACILITY. INSTALL NEW LIGHTINGS AND RECEPTACLES. PC FOR T-24 ONLY. TOTAL AREA: 8,082 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68317	15041-10000-34671	300 S GRAND AVE Ste 302	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	PIN	34.05243427	-118.25124731	T-24, TI to an existing commercial building (offices). Existing services and equipment. Installing new lighting. Scope is being done on suite 350. Sq ft = 2670	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68318	18041-20001-39544	12338 W VENTURA BLVD	91604	2	162B165   263	2369002022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			01/22/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.14278	-118.40219	Revisions to approved set.  Change of luminaire schedule, lighting and switch locations, updated controls.  (((ti to an existing commercial building.  adding new lightinng new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68319	17041-10000-02399	1510 N SAN PABLO ST	90033	14	135A225    62	5202004042	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM			PC Approved	01/24/2017 12:00:00 AM	ADDRESS	34.06266	-118.20215	PC FOR ADDITION OF 2 LIGHTPOLES FOR SITE LIGHTING. PROVIDING T24. PC ENERGY ONLYPLAN CHECK ONLY!!!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68320	13041-10000-16806	12555 W JEFFERSON BLVD 150	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM	06/27/2013 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	ADDRESS	33.97954	-118.41361	permit to be pulled at EPC counter only. permit for energy only. TI FOR EXISTING BUILDING. 3 SPACES TO 1 FOR OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68321	17041-10000-34421	10250 W SANTA MONICA BLVD UNIT# 1340	90067		132B161   512	4319003066							Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Plan check for sign lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68322	17041-10000-00210	11224 W ARMINTA ST	91352	6	189B173   527	2314011013	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2017 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Expired	03/24/2024 12:00:00 AM	ADDRESS	34.21337	-118.37557	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(28)MODULES-AXITEC AXIPOWER AC-265P(1)INVERTER-FRONIUS PRIMO 7.6-1	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68323	18041-10001-15494	11949 W FOXBORO DR	90049	11	132B141   146	4404017004	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.06058	-118.47367	Changes to approved set, adding an AC disconnect((PC FOR ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER with 4 poweralls (125A). PV IS EXISTING.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68324	16041-10000-10265	9321-9323 W PICO BLVD	90035	5	132A167   202	4330035013	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.05542	-118.39345	T-24 to a new synagogue building consisting of kitchen, restrooms, storage. Scope of work includes a new 400 amp service, new lighting for outdoor and indoor. and receptacles. occupancy load A is < 100. total Sq. ft. 6382T-24 is 2013 standard per applicant's request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68325	12041-20000-05337	22284 W BUENAVENTURA ST	91364	3	168B101   680	2170003015	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2012 12:00:00 AM	04/23/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.15532	-118.61277	pv system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68326	12041-10001-30170	909 W TEMPLE ST BLDG A	90012	9	133-5A211  74	5161001036	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Apartment			10/08/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.06102	-118.24942	[[10/8/14  CHANGES TO APPROVED SET OF PLANS, DELTA 1 CHANGES ONLY. LIGHTING AND A CIRCUIT FOR THE BRIDGE BETWEEN BUILDING A AND B ]]]New 287 unit apartment building (15 typical units).  Mixed used with 1st floor being for commercial use and 6 floors on top for residential use.  One level of subterranean parking and 2 above grade.  Fire alarm plans are not included in the submittal.  A fire alarm variance must be filed.  BLDG A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68327	19041-20000-48870	24345 W CLEAR CREEK PL	91304	12	192B089   223	2017038024	RE9-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	02/11/2020 12:00:00 AM	ADDRESS	34.21931	-118.65606	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 7.68 KW DC/ 7.6 KW AC. SCOPE OF WORK CONSISTS OF (24) PV MODULES WITH A 7.6 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68328	14041-20000-06016	510 S NORMANDIE AVE 1-40	90020	10	135B197   812	5502018022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			03/05/2014 12:00:00 AM			Reviewed by Supervisor	03/18/2014 12:00:00 AM	ADDRESS	34.06494	-118.30016	PV2 ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMED INVERTERS. TOTAL SYSTEM SIZE 23KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68329	12041-10000-07855	2036 S WESTGATE AVE	90025	11	123B149   342	4262033015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM	04/05/2012 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.03454	-118.45226	Plan check for replacing existing fire alarm control unit and devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68330	13041-10000-22301	5409 N ALDEA AVE	91316	5	174B133   817	2258001025	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	ADDRESS	34.16941	-118.50819	PV1.  INSTALL 11.5 KW AC ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT INTO UPGRADED MAIN SERVICE PANEL (NEW PANEL UNDER SEPARATE EXPRESS PERMIT)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68331	19041-10000-45541	5121 N COLBATH AVE	91423	4	171B153   579	2269007014	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	08/05/2020 12:00:00 AM	ADDRESS	34.16367	-118.43668	[EPLAN] ADDING 1 TESLA POWERWALL (5.8KVA) TO AN EXISTING ROOF-TOP SOLAR.CONNECTED TO A 200 AMP EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68332	19041-10000-23176	19191 S VERMONT AVE #850	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	Energy plan check for an office T.I located on the 8th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 4867-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68333	17041-10000-15538	20420 W VIA GALILEO	91326	12	219B109   295	2701056014	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Permit Finaled	07/14/2017 12:00:00 AM	ADDRESS	34.29602	-118.57929	Installation of new roof mounted solar PV array on existing single family dwelling.  Microiverter system.  Total system size = 9.75 kWac	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68334	18041-10001-37363	4525 W WILSHIRE BLVD STE. 150	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/17/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE ADDITION OF DAYLIGHT SENSORS UNDER DELTA 2. _____________________________________PC FOR ENERGY ONLY, TENNANT IMPROVEMENT WORK TO AN EXISTING SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUITS TO EXISTING PANELS. TOTAL SQ. FT. 9615.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68335	15041-10000-41983	5837 S VILLAGE DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			12/14/2015 12:00:00 AM	12/14/2015 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.97536	-118.41488	new fa system for apartment	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68336	15041-10000-16026	11111 W SANTA MONICA BLVD 7th Flr	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.04771	-118.44481	Energy plan check for common restroom and corridor located at the 7th floor of a high rise building. Scope includes new lighting in restroom and replace all exit sign in the corridor; all general light in cooridor remain as is.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68337	17041-10000-05967	20040 W PARTHENIA ST	91324	3	195B113   594	2782012013	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Issued	02/24/2017 12:00:00 AM	ADDRESS	34.22807	-118.57015	Plan check for Title 24 only in existing space, replace Outdoor existing lighting fixtures with LED fixtures. Total area: 35,425 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68338	15041-30000-44040	16127 W KNAPP ST	91343	12	198B141   492	2671019010	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.23845	-118.48364	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68339	13041-10000-27184	5100 N WOODMAN AVE 1-36	91423	4	171B157   802	2359024029	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			10/01/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.16311	-118.43103	New fire alarm system in 4-story 36-unit fully sprinklered apartment building.  140 devices, 1 new panel Edwards Systems Technology i0500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68340	17041-20002-45582	16633 W OAK VIEW DR	91436	5	168B137   395	2289020013	R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	ADDRESS	34.15694	-118.49746	02/28/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the configuration of system interconnection.*****Previous Work Description*****Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(36) 300W pv modules. (2) 5kW Tesla Powerwall 2s.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68341	18041-10000-47130	12057 W WILSHIRE BLVD	90025	11	126B145    66	4265016027	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM			PC Info Complete	02/28/2019 12:00:00 AM	ADDRESS	34.04489	-118.46677	PC SUBMITTAL PER APPLICANT REQUEST. TI ENERGY ONLY TO A GROCERY STORE. SCOPE INCLUDES NEW LIGHTING AND RECEPTALCES. TOTAL  AFFECTED AREA IS 23450SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68342	12041-20000-17010	1031 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	11/13/2012 12:00:00 AM	PIN	34.02400284	-118.2895744	fire alarm student health center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68343	17041-10001-29574	835 W JEFFERSON BLVD 1082	90089	9	120A201    22	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM			PC Info Complete	09/05/2017 12:00:00 AM	ADDRESS	34.02414	-118.28458	PC FOR RETAIL TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS PERMIT UNDER MASTER. TOTAL AFFECTED AREA 400 SQ.FT..PLAN CHECK ONLY!!!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68344	19041-10000-20471	5515 N FIGUEROA ST	90042	1	151-5A227 258	5468024008	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM			PC Approved	07/29/2020 12:00:00 AM	ADDRESS	34.10866	-118.19506	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF EXTERIOR LIGHTING - TOTAL AFFECTED AREA = 25,962 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68345	10041-10000-15658	3127 N SAN FERNANDO ROAD	90065	13	154-5A213 222	5458008014	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.01	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	08/19/2010 12:00:00 AM	PIN	34.11563831	-118.24628261	T.I. to existing building (California Check Cash).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68346	17041-10001-26113	9047 N MORNING GLOW WAY	91352	7	195B181   147	2403027008	RE20-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.23315	-118.34541	EXPEDITE PER APPLICANT REQUEST ****************************************PC FOR ROOF MOUNTED PV SYSTEM ON SFD. SYSTEM SIZE 15.12KW ACSCOPE INCLUDES 42 AC MODULES WITH SOLAR PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68347	19041-20000-29072	2604 S MIDVALE AVE	90064	5	123B157   190	4256031023	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.03605	-118.42633	Plan check for PV roof mounted with battery back up system, PV system size: 6.4KW with 20 PV Modules and 1 inverter(7.6KW), LG Battery 9.8KWh	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68348	15041-10001-28935	11831 N CHADRON AVE	91331	7	216B161   628	2527002015	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	34.28496	-118.41578	expedited per customer request. (((PV1 for a single family home. Scope of work: (16) modules, (1) inverter of 5kw rating.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68349	14041-10000-11983	3430 S VERMONT AVE	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.02479	-118.29132	plan check for power only. FEEDER FOR TEMPORARY state-approved TRAILER FACILITY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68350	14041-10000-09924	8600 N VAN NUYS BLVD	91402	6	192B149    49	2638001040	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.2263	-118.44918	CHANGE OF USE FROM RETAIL TO DENTAL OFFICE. PC FOR POWER AND ENERGY. HEALTH CARE FACILITY IN ACCORDANCE TO ART. 517. TOTAL AREA 4114 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68351	17041-10000-04766	2025 S FIGUEROA ST	90007	9	123A205    30	5126003025	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.03246	-118.27359	CHANGING OUT OLD FIXTURES FOR MORE ENERGY EFFICIENT. PC FOR T24 ENERGY ONLY. TOTAL AFFECTED AREA IS 46800 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68352	12041-10000-06954	10800 W PICO BLVD #357	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	ADDRESS	34.04054	-118.4272	Plan check T24 Energy for retail TI space #357	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68353	18041-10001-12312	700 N HENRY FORD AVE	90744	15	030B213   140	7440002035	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	33.77971	-118.24145	PLAN CHECK FOR POWER ONLY FOR INSTALL 2 NEW MCC SECTIONS RATED AT 1600A 480/277 TO EXISTING DISTRIBUTION EQUIPMENT - SCOPE INCLUDES ADDITION OF NEW MOTORS WITH NEW CONNECTED LOAD OF APPROX. 300A OF NEW CONNECTED LOAD. SCOPE OF WORK IS CLOUDED UNDER DELTA 13 & 14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68354	14041-10000-04137	3060 S CRENSHAW BLVD	90018	10	120B185  1546		[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.02579	-118.33489	PLANCHECK FOR POWER AND ENERGY. TI TO AN ( E) RETIAL STORE. 99 CENT ONLY STORE. BUILDING P# 14016-40000-02634	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68355	16041-20000-19805	10989 W ROCHESTER AVE 1-63	90024	5	132B153   800	4324006020	[Q]R4-1L	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Apartment			06/06/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.05561	-118.44536	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68356	14041-10000-16629	20924 W VANOWEN ST	91303	3	180B109    20	2148027026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.19358	-118.58925	Title-24 plan check only.  Total area = 1,288 sq. ft.Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68357	19041-20000-32067	20814 W ACORN CIR UNIT #233	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	02/10/2020 12:00:00 AM	ADDRESS	34.29429	-118.58717	PV1.  Install 3.15 kW roof mounted PV system.  (9) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68358	19041-10000-53088	300 W AVENUE 33	90031	1	142-5A221 290	5205006053	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	01/03/2020 12:00:00 AM		Permit Finaled	04/28/2021 12:00:00 AM	ADDRESS	34.08346	-118.21585	TI IN OFFICES AND JANITOR ROOMPLAN CHEK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68359	17041-20000-28037	12259 N LIMA WAY	91342	7	219B149   934	2611046026		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.29405	-118.45602	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68360	18041-20000-00606	5900 W WILSHIRE BLVD #2950	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			PC Approved	01/05/2018 12:00:00 AM	ADDRESS	34.06237	-118.35809	PLANCHECK FOR T24 ENERGY.  INTERIOR OFFICE T.I.  (E) OFFICE SPACE. (4052 S.F.)BUILDING PERMIT # 17016-10000-33965	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68361	18041-30000-06245	6751 N FALLBROOK AVE	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.19259	-118.62408	PLAN CHECK FOR ENERGY ONLY IN AN EXISTING RETAIL BUILDING. SCOPE OF WORK INLCUDES REPLACING/RETROFIT OF EXISTING FIXTURES, NO NEW LOAD ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68362	14041-20000-26327	1565 W 228TH ST	90501	15	045B193   346	7347015029	[Q]CM-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	33.81915	-118.30594	PV1 SFD. TOTAL SYSTEM SIZE 5.6KW AC USING 2 STRINGS MICROINVERTER SYSTEM. USING 26 MODULES IN TOTAL. ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68363	14041-20000-30429	12161 N BUCKEYE AVE	91342	7	216B149   208	2611013005	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.29079	-118.45225	PV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC USING 17 MODULES. USING MICROINVERTER ENPHASE M215. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68364	15041-20000-07098	20407 W ROMAR ST	91311	12	204B113   386	2741006021	RE9-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			Reviewed by Supervisor	03/20/2015 12:00:00 AM	ADDRESS	34.25471	-118.57755	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (20) modules and (1) inverter. Standard plan is not being used and was submitted per applicant request.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68365	15041-20000-14969	16600 W SHERMAN WAY # 270	91406	6	183B137    71	2225005010	(Q)CR-1VL, (Q)P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.20096	-118.495	PC FOR T24 ENERGY ONLY. OFFICE T24. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68366	11041-10000-04610	4760 W SUNSET BLVD 3RD Flr	90027	13	147B197   733	5543015021	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/09/2011 12:00:00 AM			PC Info Complete	03/09/2011 12:00:00 AM	ADDRESS	34.09788	-118.29343	TI IN AN EXISTING OFFICE AREA ON THE 3RD FLOOR.  (STATION  # 3105 &  #3235) PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY.  <<<<BUILDING PERMIT #11016-10000-03349>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68367	12041-10000-18544	13263 W VAN NUYS BLVD BLDG B	91331	7	207B157   309	2619017001	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	Commercial			08/07/2012 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	34.26605	-118.42245	"BUILDING ""B"". RESTORATION OF BUILDING TO SUBDIVIDE INTO 3 SMALLER BUILDINGS SEPARATED WITH WALKWAYS; INTERIOR & EXTERIOR  REMODEL.  CHANGE PORTION OF THE BUILIDNG FREOM RETAIL TO RESTAURANT.  FULL PLAN CHECK FOR SHELL ONLY IN A METHANE ZONE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68368	13041-10000-30647	1868 S KELTON AVE 1-24	90025	5	129B153   811	4323006015	R3-1-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Apartment			11/01/2013 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.04756	-118.43747	PLANCHECK FOR POWER AND ENERGY. NEW 24 UNIT APARTMENT BUILDING. 4 STORY. METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68369	11041-10000-20139	1659 N BEL-AIR ROAD	90077	5	147B149   215	4370017033	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2011 12:00:00 AM			Ready to Issue	05/25/2012 12:00:00 AM	ADDRESS	34.09969	-118.44776	New 18,000 Sqr Ft single family residence.  Full plan check per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68370	13041-10000-31568	1605 N CHEROKEE AVE	90028	13	148-5A185 268	5547014904	PF-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.09994	-118.3353	New 66-Unit Affordable Housing Apartment Building - 5-stories over podium with two subterenean parking garages. Building permit is 13010-10000-02864	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68371	14041-10001-04948	1624 W 7TH ST	90732	15	015B193   172	7559033015	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	33.73837	-118.31278	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 8.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(33) MODULES: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68372	17041-20000-09026	9110 N FOSTER LANE	91311	12	198B101   336	2727024001		North Valley			YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.23585	-118.60606	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68373	12041-20000-17009	800 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM			PC Approved	07/20/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	T.I. to existing restaurant Suite 8D.  Install general/emergency lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68374	18041-10000-12510	777 S FIGUEROA ST SUITE 1550	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	PLAN CHECK FOR TITLE 24 ONLY FOR TENANT IMPROVEMENT TO OFFICE SPACE TOTAL AFFECTED AREA = 4992 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68375	13041-10002-26817	5900 W CENTER DR	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	33.97559	-118.38853	(((6/19/2015- CHANGES MADE TO APPROVED SET. CHANGED T24 AND RELOCATION OF CIRCUITS.)))New 327-unit apartment building at Howard Hughes Center.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68376	13041-10000-13347	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	08/20/2013 12:00:00 AM	ADDRESS	34.05554	-118.41342	Alteration to outdoor courtyard lighting.  Replacement of metal halide palm tree lights with LED lighting, and additional LED lighting added by seating area.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68377	18041-10000-47225	16730 W SCHOENBORN ST	91343	12	192B137   251	2689011020	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.22245	-118.49793	REPLACE INDOOR-OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68378	17041-10001-13093	6150 W 96TH ST TEMP	90045	11	093B165   121	4124027906	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM			PC Approved	04/28/2017 12:00:00 AM	ADDRESS	33.94871	-118.39284	CHANGE TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. CHANGES TO WIRING TO SUBPANELS NOW UNDERGROUND WITH COVER PLATES. ALL WIRING IS TEMP ONLY. PC ONLY. PERMIT TO BE ISSUED UNDER MASTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68379	12041-10001-16111	13438 W OXNARD ST PV1	91401	2	177B157   881	2343021014	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Expired	01/14/2015 12:00:00 AM	ADDRESS	34.17926	-118.42606	SUPPL. APPLICATION FOR UPGRADING AN EXISTING  SUBPANEL IN THE GARAGE TO A NEW 125A PANEL. Plan check roof mounted 6.72KW photovoltaic system (Sunpower transformerless inverter). PV modules and equipment located at the detached garage. PV interconnection to existing subpanel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68380	11041-10000-02863	10780 W SANTA MONICA BLVD 3RD FL	90025	5	129B153   432	4321001090	C2-1VL, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	02/18/2011 12:00:00 AM		Permit Finaled	03/29/2011 12:00:00 AM	ADDRESS	34.0504	-118.43387	REMODEL OF EXISTING OFFICES IN A NON HIGH RISE BUILDINGPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68381	19041-20000-20607	13109 W NIMROD PL	90049	11	129B137   285	4407011010	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.05111	-118.49541	Plan check for a PV1 roof-mounted PV system. System size is 15.7 kWdc/15.36 kWac-CEC and consists of (48) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68382	12041-10000-14707	333 S ALAMEDA ST suite #-108	90013	9	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.04448	-118.23824	Change of use from retail to coffee shop 2920 s.f	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68383	18041-10001-11864	1030 N SWARTHMORE AVE 4-105	90272	11	129B125   591	4423016007	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	DELTA 3 CHANGES TO APPROVED PLANS FOR ADDING AN ACCESSIBLE DISCONNECT ON THE PRIMARY SIDE OF THE TRANSFORMER AND NEW CONDENSING UNITS.<<<PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT(RESTAURANT) - SCOPE INCLUDES CONNECTING TO EXISTING DISTRIBUTION EQUPMENT RATED AT 800A 480/277V DISTRIBUTION BOARD WITH APPROX. 400A OF NEW CONNECTED LOAD. TOTAL AFFECTED AREA 2384 SQ. FT.>>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68384	13041-10000-22427	1305-1307 W SEPULVEDA BLVD 1305,-1307-1,2,3	90501	15	042B197     8	7347018040	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/19/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	33.81372	-118.29936	CORE AND SHELL FOR TWO BUILDING 5 FEET APART. 2000 AMP SERVICE FOR BOTH BUILDINGS. 70,000 SQFT.  GOODWILL - TENANT IMPROVEMENT DONE UNDER SAME APP AS CORE AND SHELL . 3 FUTURE T.1 ( SCHLOTSKYS DELI, WELLS FARGO, AND OTHER FUTURE T.I ). PLAN CHECKER: PLEASE CHECK FEES. CALCULATED ARE CORE AND SHELL + GOODWILL T.I.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68385	19041-20000-00774	21550 W OXNARD ST STE #630	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.179	-118.60001	T-24 FOR A TI IN AN OFFICE SPACE IN A HIGH-RISE. TOTAL AFFECTED AREA IS 125 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68386	18041-10000-05741	624 S GRAND AVE PWR DIST-SYSTEM	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Closed	04/12/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	PC FOR A 4160V MEDIUM VOLTAGE TEMPORARY FEEDER INSTALLATION TO ENERGIZE TENANT SPACE ON THE 30TH FLOOR FOR IT AND COOLING LOADS. THIS IS A COMPLIMENT TO 17041-10000-37664 PERMIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68387	15041-10000-15951	10201 W PICO BLVD	90035	5	129B161  1442	4315019013	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Info Complete	05/26/2015 12:00:00 AM	PIN	34.05182951	-118.41257696	PC FOR T24 ONLY, FOX STUDIOS', REMOVING EXISTING HID LIGHT FIX WITH NEW LED FIXTURES. TOTAL ARAE 1938 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68388	17041-10000-28516	10650 N ZELZAH AVE	91344	12	207B129   626	2733005032	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.26383	-118.52309	Energy plan check for a restaurant T.I. Scope includes new lighting, receptacles and equipment.Total area is 1,395 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68389	16041-20000-07699	680 W KNOX ST	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	33.85408	-118.28767	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,890 sq. ft.Note: Building application has been generated under 16016-20000-04546	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68390	13041-20000-05932	14600 W ROSCOE BLVD	91402	6	192B149   406	2210010033	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.22136	-118.45025	New Fire Alarm system for an existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68391	19041-10000-50724	2241 N EASTERN AVE	90032	14	138A231   123	5215035046	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	03/19/2020 12:00:00 AM	ADDRESS	34.07163	-118.18066	PC FOR ENERGY ONLY, T-24. SCOPE OF WORK INCLUDES REPLACEMENT OF OUTDOOR FIXTURES TO LED LIGHTING. TOTAL OUTDOOR SQ. FT. 140325.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68392	12041-10001-21099	5570 S LINCOLN BLVD	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	10/09/2013 12:00:00 AM	ADDRESS	33.97271	-118.43031	REVISIONS TO APPROVED SET OF PLANS. ADDITION OF 5 CIRCUITS FOR SHADES. REARRANGMENT OF EQUIPMENT AND CHANGES IN T24 ENERGY COMPLIANCE. COUPLE NEW FIXTURES. MINOR CHANGES.TI IN AN EXISTING COMMERCIAL BUILDING. CHANGE OF USE TO A NEW LA FITNESS CENTER ON FIRST FLOOR OF 2 STORY BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68393	17041-20000-12563	307 N WILMINGTON BLVD VISTA DEL-MAR	90744	15	027B205   209	7417010905	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			04/18/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.77243	-118.27378	4/18/2017Changes to an approved set of plans.  Changes noted delta 5.  Changes reflect energy, panels and circuits.(((Plan check for new appartment building 12 residential buildings, with total of 88 units, include new services, site lighting, community blde. Total area: 2000 sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68394	19041-20000-17515	443 S SAN PEDRO ST	90013	14	127-5A213 105	5148011018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Apartment			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Permit Finaled	11/23/2020 12:00:00 AM	ADDRESS	34.04477	-118.24374	new fire alarm system 195 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68395	12041-10000-04174	10880 W WILSHIRE BLVD #1800	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Finaled	01/03/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	Ti in an office BLDG Suite #1800. Plan check for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68396	15041-20001-43772	6014 N PASEO LA VISTA	91367	3	177B085   239	2032030012	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM			PC Approved	02/02/2016 12:00:00 AM	ADDRESS	34.18183	-118.66704	Expedited per applicant request.PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 17.49KWdc/15.2KWac.(66)KYOCERA #KU2656ZPA(2)INVERTER-FRONIUS #PRIMO 7.6(1)125A SUBPANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68397	13041-20000-23760	4652 N WILLENS AVE	91364	3	168B097   540	2074042010	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Expired	10/06/2015 12:00:00 AM	ADDRESS	34.15539	-118.62691	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.6 KW USING 23 MODULES. NONSTANDARD PLAN TRANSFORMERLESS INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68398	15041-10001-19672	1515 N LYNTON AVE	90744	15	036B201   547	7414022028	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	10/08/2015 12:00:00 AM	ADDRESS	33.79278	-118.28163	pv1, install 3.8 kw ac roof-mounted solar array on a one single family home. (16) modules: et solar et-p672295(1) inverter: abb pvi-3.8-outd-us** $0 Fess per Senate Bill 1222Reference application#:  15041-10000-19672	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68399	14041-10000-33733	2050 N EDGEMONT ST	90027	4	150B197   266	5589020021	RE11-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.10899	-118.29635	PV1.  Install 12.75 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.  FEES AMOUNT REFLECT ON SENATE BILL 1222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68400	16041-20000-13209	5245 N LANKERSHIM BLVD	91601	2	171B173   439	2350017034	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.16601	-118.37573	Plan check for power only. Project site is an existing commercial building. Project scope is the replace of a 600-amp service distribution board.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68401	18041-10000-42174	11840 W FOOTHILL BLVD UNIT G	91331	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.27349	-118.39431	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1033 SQ. FT. B#18016-20000-08618	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68402	11041-10000-01491	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	New fire alarm system for the Tom Bradley terminal. EPC is for power. (South concourse)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68403	14041-20000-00048	2377 N WEST SILVER LAKE DR	90039	4	148-5A207  32	5439028006	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/02/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.1031	-118.26668	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68404	16041-20000-38804	361 E VERNON AVE	90291	11	109-5A143  61	4286007015	CM-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	33.99527	-118.47314	11.2.2016 - Plan check for energy only. New lighting for warehouse. 9,967sqft.Permit pulled under application #16041-30000-36236.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68405	19041-20000-31471	10949 W PENDLETON ST	91352	6	198B173    20	2538012014	[T][Q]MR1-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1211.02	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	11/11/2020 12:00:00 AM	ADDRESS	34.24084	-118.37016	TENANT IMPROVEMENT REPLACING ELECTRICAL EQUIPMENTS, ADD NEW LIGHTS, AND PANELS. TOTAL SQUARE FOOTAGE = 20527 SFB#19016-10000-25035	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68406	15041-30000-41233	8957 W DAVID AVE	90034	10	126B169   871	4302017030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.04024	-118.38669	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 4 kWac.  Microinverter system with 1 branch.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68407	14041-10008-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			02/26/2018 12:00:00 AM			PC Approved	02/26/2018 12:00:00 AM	ADDRESS	33.95605	-118.38499	added changes REFERENCING BULLETINS #4, # 5, & # 7 : NEW CIRCUITS AND A PANEL BOARDAND NEW LOADSPLAN CHECK ONLY	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
68408	13041-10000-14368	3620 S MCCLINTOCK AVE 226 & 601	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			Not Ready to Issue	06/27/2013 12:00:00 AM	ADDRESS	34.0213	-118.28935	PLAN CHK TO VERIFY THAT LUMINAIRES IN ROOMS 226 & 601 AREIN COMPLIANCE WITH TITLE 24 AFTER BEEN REMOVED ,CLEANED AND PUT BACK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68409	17041-20000-46645	1543 N WESTERLY TER	90026	13	144A205   344	5425011022	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	Yes	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.08827	-118.27051	Plan check for AC coupled battery backup system for SFD.(2) 5kW Tesla Powerwall 2s. Existing solar pv system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68410	13041-10000-21668	8917 N RESEDA BLVD	91324	12	195B125   372	2770005015	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM			PC Approved	08/19/2013 12:00:00 AM	ADDRESS	34.23242	-118.53628	LIGHTING , TITLE-24 ONLY FOR SWIMMING POOL SCHOOL; CONVERTING FROM RETAIL STORE. THE TOTAL AREA FOR THIS PROJECT IS 4803 SF. PERMIT NOT INCLUDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68411	19041-10000-20087	950 E 10TH ST	90021	14	123A211    38	5132008048	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.0329	-118.24749	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68412	13041-10000-09671	11845 W CHAPARAL ST	90049	11	135B141   538	4402006006	RE15-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.06484	-118.47369	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A TWO STORY FAMILY DWELLING. SYSTEM SIZE IS 9.39 KW. [MODULES: PHONOS SOLAR # PS260M-20/U INVERTER: SMA # SB10000TL]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68413	14041-20001-14886	10118 N LURLINE AVE	91311	12	204B109   320	2741026040	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.25408	-118.58406	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof mounted solar array on SFD. System size 6kW(1) SolarEdge SE6000A-US-ZB-U transformerless inverter(30) Trina Solar #TSM-255PA05.18 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68414	13041-10000-15927	9616 W PICO BLVD	90035	5	132A167   260	4306001037	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			06/17/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.05497	-118.39811	pc for power and energy. interior remodel of the (e) ralphs store, removal and replacement of sales area and food prep area fixtures with all associated electrical items. remodel (e) interior lighting	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68415	17041-20000-14970	957 N FIGUEROA TER	90012	1	136-5A213  93	5406024005	RD1.5-1	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Apartment			05/08/2017 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	07/07/2021 12:00:00 AM	ADDRESS	34.0678	-118.24372	Plan check for power and energy. New 3-story, 28-unit condominium buildng w/basement. 1,600A service. Project is located in a methane zone. Fire alarm variance filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68416	10041-20000-18536	8445 W 3RD ST	90048	5	138B173   721	5511013017	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/17/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	10/22/2010 12:00:00 AM	ADDRESS	34.07332	-118.37471	"energy plan check  ""COMPLY WITH DEPARTMENT ORDER effective date 02/18/2004. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68417	15041-10001-31011	14400 S FIGUEROA ST	90248	15	075B201    98	6129001029	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			Reviewed by Supervisor	12/24/2015 12:00:00 AM	ADDRESS	33.9008	-118.28265	INSTALL 30 KW INVERTER FOR PEAK SHAVE SYSTEM.pc for utility interactive battery system. this is plan check only. permit already issued under master application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68418	14041-10001-34648	1073 S BROXTON AVE	90024	5	132B149    72	4363024003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM			PC Approved	02/26/2016 12:00:00 AM	ADDRESS	34.06118	-118.44618	02/26/16Changes to an approved set of plans. All changes are made under delta 9. Changes include removing seven LED lighting fixtures on floor plan.Note: Permit pulled under PCIS#14041-10000-34648(((((plan check for energy 2013 Standards. TENANT IMPROVEMENT PROJECT OF A RESTAURANT IN AN RETAIL SPACE.  CAVAGRILL WILL OCCUPY 2,000 SF. BLDG#14016-10-25298	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68419	18041-10000-32620	4641 N VISTA DE ORO AVE	91364	3	168A111   102	2174015027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	34.15394	-118.58137	No Fee per AB1414PV1 16KW AC roofmounted system with (56) microinverter and modules interconnecting through the load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68420	17041-20000-40096	8480 W BEVERLY BLVD 1A	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/06/2017 12:00:00 AM	04/02/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	34.07577	-118.37599	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL ( TARGET). 72497 SQFTBUILDING PERMIT # 17016-20000-32724	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68421	07041-10004-23889	311 S GRAMERCY PL APT 1-30	90020		135B193   278	5504024015	R4-1		Wilshire	Greater Wilshire			Electrical	Electrical	Apartment			07/27/2010 12:00:00 AM			PC Approved	07/27/2010 12:00:00 AM	ADDRESS	34.06845	-118.3131	DELTA 7 FIELD REVISIONS TO PERMITTED SET OF PLANS; USING OCCUPANCY SENSOR TO CONTROL WALL-MOUNTEDLUMINAIRES  IN EACH MASTER BATHROOM AND  CEILING LUMINAIRE IN EXERCISE ROOM ; NEW CIRCUIT FOR FA CONTROL PANEL ; INCREASE SIZE OF SUMP PUMP MOTORS TO 15HP EACH TO BE SUPPLIED FROM HOUSE SWBD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68422	15041-20000-06839	5507 N MORELLA AVE	91607	2	174B169  1087	2348003039	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.17059	-118.39008	PV1. Using standard plan. Install roof mounted PV system on SFD sized 7.2 kW. Ungrounded system. Interconnected to 200A main service panel.24 modules 327W1 3.0 TL Inverter1 4.2 TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68423	15041-10000-25397	1930 W LEIGHTON AVE	90062	8	114B189    31	5035012006	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.01261	-118.31616	PV1 3KW roof-mounted system with (10) Kyocera KU2656 modules and (1) ABB PVII-3.0 OUTD inverter added to an existing PV system; Total whole PV system (new and old) will be 6.6KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68424	18041-10000-31347	707 W WILSHIRE BLVD 46Th Floor	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Issued	08/23/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	TI IN AN EXISTING OFFICE AREA ON THE 46TH FLOOR. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-24936	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68425	19041-10000-03521	15271 W SUNSET BLVD	90272	11	129B125   863	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/29/2019 12:00:00 AM	03/06/2019 12:00:00 AM		Issued	03/06/2019 12:00:00 AM	ADDRESS	34.04685	-118.52493	FULL PLAN CHECK FOR FIRST TIME TENANT, POWER AND T-24. TOTAL AREA OF WORK IS 1052 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68426	11041-10000-20591	5745 W ARBOR VITAE ST	90045	11	093B169    66	4125010006	MR1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/27/2011 12:00:00 AM			PC Approved	11/01/2011 12:00:00 AM	ADDRESS	33.95278	-118.38314	Change to original scope of work for app. 10041-10000-24057 for new lighting. T-24, Energy - PLAN CHECK ONLY.  <<<<<<CONVERT TWO STORY, TYPE III-B, 145' X 208', OFFICE AND WAREHOUSE TO OFFICE AND AUTOMOTIVE BODY/FENDER REPAIR WITH SPRAY BOOTHS.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68427	11041-10000-09678	5338-5340 N TOPANGA CANYON BLVD	91364	3	171B101   363	2169003025	C2-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			05/12/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	09/21/2011 12:00:00 AM	ADDRESS	34.16701	-118.60555	Installing 35 devices, two relays and 3 batteries plus one panel for a two story commercial bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68428	16041-10000-09578	4910 N DUNMAN AVE	91364	3	168B097   165	2074006016	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.15931	-118.62679	PV1, rooftop solar installation   10kW system      (40) CS6P-255P        (1) SE10000A-US        P300 is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68429	16041-20000-16961	6922 W HOLLYWOOD BLVD #900	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/13/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.10137	-118.34103	Plan check Title 24 only T.I. in existing building. Total area: 5,330 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68430	16041-10002-42534	642 S MAIN ST	90014	14	127-5A211  97	5148021010	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	34.04426	-118.25074	Changes to approved set.  All changes clouded with delta 1.  Addition of new display lighting and outdoor lighting.  Circuits updated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68431	13041-10001-32994	4731 N TYRONE AVE	91423	2	168B153   465	2248002012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.1569	-118.44446	Expedited RSES plan check per applicant request.[][]PV1, Install 10.5 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(2)Transformerless inverter(s): SolarEdge SE5000A-US. (42) modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68432	18041-10000-31248	14635 W KESWICK ST	91405	6	189B149   562	2210025005	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.21048	-118.45205	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68433	13041-10000-35830	5858 N SHOUP AVE SHADE BLDG-#1	91367	3	174B101    17	2146009901	OS-1XL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM			PC Info Complete	06/06/2014 12:00:00 AM	ADDRESS	34.17705	-118.6144	PLAN CHECK FOR POWER AND ENERGY FOR NEW SHADE BUILDING.   (2 OF 4 ) ALL FEES FOR ENERGY ARE UNDER APPLICATION # 13041-10000-35818.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68434	14041-10001-14925	11906 W SARAH ST	91607	2	168B169   897	2364004014	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.15388	-118.39241	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.61 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERACT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68435	19041-10000-28598	14339 W HAMLIN ST	91401	2	180B149   593	2237015024	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.18885	-118.44569	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68436	17041-20002-03101	3397 N BARHAM BLVD	90068	4	159B181   187	5579007022	CR-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			11/20/2019 12:00:00 AM			PC Approved	11/20/2019 12:00:00 AM	ADDRESS	34.1333	-118.34402	11/20/19CHANGES TO APPROVED SET DELTA C ONLY.<<<PLANCHECK FOR POWER AND ENERGY. new three story commerial building 800 amp service.  building permit # 14010-20000-01950>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68437	18041-20001-21812	3057 W PICO BLVD	90006	10	129B193  1247	5080012033	(T)(Q)RAS4-1	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Apartment			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.04734	-118.30781	12/11/19CHANGES TO APPROVED SET DELTA B ONLY CHANGES TO FEEDERS. <<<Plan check for power and energy new 6 story mixed use building 51 units appartment.  Total area: 61,588 sq ft    B#15010-10000-03721Fire alarm variance has been filed.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68438	14041-10000-08909	1645 S LIVONIA AVE	90035	5	129B169   779	4305011017	R1-1	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.04959	-118.38664	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68439	15041-10000-08737	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.07196	-118.24719	Energy plan check for a commercial T.I in level-2 sector-3 ,elevator lobby and Am/Pm market area. Total area is 186-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68440	13041-10000-29670	17720 W MAGNOLIA BLVD	91316	5	171B129   198	2162013005	(T)(Q)R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Apartment			10/23/2013 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.16526	-118.51937	Plan check for new 50 unit apartment building with 2000A service supplying building. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68441	18041-20000-13443	22420 W VANOWEN ST	91307	12	180B101    36	2038028032	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.19357	-118.61551	PC for 7.6kW(ac)/6.49kW(dc) rooftop solar for SFD with 5kW back-up battey . Installing 22 modules with optimizers, multimode inverer, auto transformer, backup panel and 5kW back up battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68442	15041-20001-35105	1000 S WESTWOOD BLVD	90024	5	135B153   617	4363020006	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM			PC Approved	03/04/2016 12:00:00 AM	ADDRESS	34.06224	-118.44512	Minor revisions to lighting plan layout based on architectural revisions (relocated door).  (((Full plan check for power and energy T.I. retail store. Total area: 5,151 sqft. Total load exceed 400A.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68443	18041-20000-44686	637 W WILSHIRE BLVD Level 1-Suite 150	90017	14	129A209    55	5144005031	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	09/11/2019 12:00:00 AM	ADDRESS	34.04869	-118.25681	Plan check for Title 24 only in existing high rise building. Total area: 1035 sq ft. B18016-30000-35517	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68444	15041-20001-20548	3442 N COLVILLE PL	91436	5	159B137   284	2287012046	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM			PC Approved	07/05/2015 12:00:00 AM	ADDRESS	34.1329	-118.49628	Expedited per customer request. PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel.(56) Kyocera KU2656 Modules(2) PVI-6000 TL Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68445	13041-20000-34557	3304 W BELLEVUE AVE	90026	13	141A201   380	5401013017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Expired	01/26/2016 12:00:00 AM	ADDRESS	34.07875	-118.2804	New rooftop pv system for an existing sfr.  System uses DC-DC converters and is UNGROUNDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68446	16041-20000-12063	11427 N PORTER RANCH DR	91326	12	213B113   325	2701072004	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.27867	-118.57253	Plan check for a PV2 carport PV system. System size is 111.6 kWdc and consists of (6) inverters, (372) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68447	16041-20000-31784	10370 W GLENBARR AVE	90064	5	126B161   282	4318028004	R1-1	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.04003	-118.41015	Plan check for roof-mounted solar array on a SFD. Interconnect with 400A split bus panel. 7.7kW ungrounded system. (33) 270W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68448	18041-20002-24074	1800 N VINE ST	90028	13	150A189   287	5546033022	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Issued	11/30/2018 12:00:00 AM	ADDRESS	34.10393	-118.3265	11/30/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Emergency egress lighting is now fed from a 277V inverter. There has been an addition of a new subpanel and loads have been revised to reflect field conditions. *****Previous Work Description*****This is a plan check only to approved set. Revised light fixtures, updated T24 calculation, and updated photometric. All changes are clouded on the plan.<<Plan check for Title 24 only. Project site is the 1st floor of a 3-story commercial building. Project scope is a tenant improvement. Total lighting area = 13,310 sq. ft.>>Note: Building application has been generated under 18016-10000-14441	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68449	10041-20000-13292	10960 W WILSHIRE BLVD 7th floor	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			07/13/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	12/03/2010 12:00:00 AM	ADDRESS	34.058	-118.44597	Plan check T-24 Energy general/emergency lighting for office TI on the 7th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68450	18041-20000-30751	17620 W OSBORNE ST	91325	12	195B129   148	2768027011	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.23336	-118.51875	Plan check for 5 addition of PV modules to existing 7.6kW PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68451	15041-10000-43504	7220 S AVALON BLVD	90001	9	102B205   991	6023001001	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.01	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	PIN	33.9741048	-118.26485048	PC for energy only. Remove HID light fixures and replace with new LED fixtures. Total sq ft = 3580	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68452	19041-10000-13398	1601 S VICTORIA AVE	90019	10	126B185   134	5071004001	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.04485	-118.32987	[ePlan]  Install (1)  Energy Storage System @13.5KWH to Existing PV System, (1) New 200A load center. New 200MSP shall be under separate express permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68453	16041-10000-31533	1900 N OLD RANCH ROAD	90272	11	135B133    40	4432010009	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2016 12:00:00 AM			PC Info Complete	10/12/2016 12:00:00 AM	PIN	34.06858065	-118.50530699	plan check for power only for a new two story house.  Scope includes a new 120 /240V single phase 3wire service and new panel boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68454	19041-30000-46377	3901 S BROADWAY	90037	9	115-5A203  13	5122045025	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	09/25/2020 12:00:00 AM		Permit Finaled	04/25/2023 12:00:00 AM	ADDRESS	34.0125	-118.27827	FULL PC FOR A TI. SCOPE OF WORK IS A NEW 800A (208/120 3P,4W) SERVICE THAT FEEDS (6) SUBPANELS. NEW LIGHTS, CONTROLS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA IS 22,341 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68455	15041-20000-27355	1425 N SAN PABLO ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	34.06176	-118.20365	PLANCHECK FOR T24 ENERGY. T.I. TO ENLCOSE EXISTING OFFICE SPACE AND CONFERENCE ROOM. 780 SQFT. OFFICE 200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68456	15041-20001-36835	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	33.97615	-118.42138	8.24.2016 - Plan check for modifications to approved set. Relocating/rearranging service and distribution equipment. Adding outdoor lighting (T-24), 3,315sqft. Changes clouded.=====Core&Shell of a new build.. MSB 2500A. Building located on a Methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68457	18041-20000-49102	11019 N ARLETA AVE	91345	7	210B149   940	2615014019	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/12/2019 12:00:00 AM	ADDRESS	34.27023	-118.45482	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68458	16041-20000-15642	11267 W VENICE BLVD	90066	11	114B157   118	4234002037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.01204	-118.41926	PLANCHECK FOR T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68459	14041-20000-01953	20847 W KINGSBURY ST	91311	12	207B109   404	2706011049	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.26372	-118.58817	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68460	15041-10000-36493	933 W 76TH ST	90044	8	099B197    69	6020008028	RD1.5-1	South Los Angeles	South Los Angeles			2377.10	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Expired	11/29/2017 12:00:00 AM	ADDRESS	33.97084	-118.29042	PV1, INSTALL 6.89 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(26) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68461	15041-10001-25397	1930 W LEIGHTON AVE	90062	8	114B189    31	5035012006	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	34.01261	-118.31616	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.PV1 3KW roof-mounted system with (10) Kyocera KU2656 modules and (1) ABB PVII-3.0 OUTD inverter added to an existing PV system; Total whole PV system (new and old) will be 6.6KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68462	14041-10000-23620	12003 S AVALON BLVD	90061	15	084B205  1210	6086024029	OS-1XL, [T][Q]C2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	03/09/2015 12:00:00 AM	ADDRESS	33.9232	-118.26541	PLANCHECK FOR T24 ENERGY. REPLACE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. 2776 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68463	16041-10001-45662	5263 W ADAMS BLVD	90016	10	123B177   911	5043003018	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.03266	-118.35751	DELTA 2 CHANGES TO AN APPROVED SET. T-24 ONLY. CHANGES TO AN APPROVED SET TO INDOOR AND OUTDOOR LIGGHTING. TOTAL AFFECTED AREA IS 23403 SQ.FTORIGINAL SCOPE((PC FOR POWER AND ENERGY. NEW 3 STORY MIXED USE,  14 UNIT   APARTEMENT BUILDING WITH ONE LEVEL SUBTERRANEAN PARKING GARAGE. ( TOTAL  3 STORY BUILDING). SERVICE 1200A , 208/120V, TOTAL AREA 17200 SQ FT.B# 16010-10000-05038))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68464	15041-10000-10972	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	04/27/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	PIN	33.92817449	-118.43220714	Plan check for power only; Hyperion Dice II Centrifuge #4, installation of new 480v 600-Amp VFD drive controlling a 300-HP and a 75-HP motors.  Scope also include a demolation of  a 4160v 600hp  and a 100Hp back drive.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68465	19041-10000-07172	10943 N HERRICK AVE	91331	7	210B161   718	2534024905	OS-1XL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.26922	-118.41302	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR) -T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68466	13041-10000-10748	18566 W MARILLA ST	91324	12	201B121   440	2763033040	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.24683	-118.53853	pv1 single family dwleling. microinverter standard plan. using enphase micro inverter. total system size 5.8kw. using 27 modules. photovoltaic system for single family dwelling. upgrade of main panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68467	16041-10001-18374	12030 W RYNGLER ROAD	91604	2	162B165   675	2369019031	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.13985	-118.39295	Expedite per Applicants request.(New 12 kW AC PV installation. 44 Canadian Solar PV modules. Installing 2 SMA SB6000TL-US Inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68468	11041-10000-15345	2801 W JAMES M WOOD BLVD	90005	1	132B197   733	5077024012	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Expired	08/14/2013 12:00:00 AM	PIN	34.05617146	-118.28922798	T.I.  Existing 7-11.  Replacing 28 light fixtures, using the existing branch circuits, in the retail space only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68469	17041-20003-22682	3530 W WILSHIRE BLVD	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM			PC Approved	03/21/2019 12:00:00 AM	ADDRESS	34.06154	-118.30122	Removal of separate AC disconnects at inverter locations. Inverters have integral AC disconnects.$0 plan check fee per State Senate Bill SB 1222.  3/7/2019CHANGE TO APPROVED SET, CHANGE FROM 688 PHONO SOLAR 325W PV MODULES TO 649 HANWHA Q CELLS 390W PV MODULESTHIS IS PLAN CHECK ONLY.7/31/2018changes to an approved set of plans.  changes to reduce system size to 180KW AC with line side tap.  (688) phono solar 325W(3) yaskawa solectria 60KWThis is plan check only.*****Original Scope of Work*****Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,054) modules, and (1) load center on parking structure. Note: Permit Fees $0 Due to SB 1222 Note: Building application has been generated under 17014-30000-03172	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68470	19041-20000-48131	19623 W KILFINAN ST	91326	12	219B117    16	2701019013	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.29773	-118.56131	PV1. INSTALL 14.0 KW DC PV SYSTEM WITH (40) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68471	16041-10000-28909	4270 S VERMONT AVE	90037	9	114B197  1038	5020034034	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM			PC Approved	08/15/2016 12:00:00 AM	ADDRESS	34.00585	-118.2913	NEW LIGHITNG FOR RETAIL AREA. PC FOR T24 ENERGY ONLY. PERMIT ALREADY ISSUED UNDER APPLICATION # 16041-70000-28329	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68472	13041-10000-11601	11150 W SANTA MONICA BLVD suite 825	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/06/2013 12:00:00 AM			PC Approved	05/13/2013 12:00:00 AM	ADDRESS	34.04704	-118.44563	Tenant improvement for a highrise-bldg  on the 8th story, suite 825.  Newly connected load < 400 A, title 24 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68473	17041-10000-32099	3000 S ROBERTSON BLVD suite 215	90034	10	123B169   884	4311033015	C4-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/03/2018 12:00:00 AM	ADDRESS	34.03242	-118.39001	PC for T24 only for office TI in second floor suite 215. Installing new lights and surface mounted receptacles.  Total area of 2558sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68474	15041-10001-40348	3535 E GARNET ST	90023	14	120A227   174	5191011017	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.02169	-118.20032	Supplemental PC to permit 15041-10000-40348: revised rooftop modules orientation & relocate load center.<<PV1 SFD TOTAL SYSTEM SIZE 3KW AC USING CENTRAL INVERTER WITH 9 MODULES. CONNECTED TO NEW LOAD CENTER.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68475	14041-20001-18880	9010 N RESEDA BLVD	91324	12	195B125   108	2769001022	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	ADDRESS	34.23445	-118.53589	Changes to approved set.  Future inverter for solar moved from seperate section to part of switchgear.  Removal of meter from switchgear.  Minor changes to lighting.  Addition of heat lamps.*****Previous Work Description*****NEW RESTAURANT, PER OCCUPANT LOAD, PLACE OF ASSEMBLY. PLAN CHECK FOR POWER AND ENERGY. PER BUILDING SUBMITTAL, ENERGY COMPLIANCE ACCORDING TO 2013 EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68476	18041-10000-09768	1500 N EL CENTRO AVE 2ND FLR.	90028	13	147A189   234		(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM			Plans on Hold	04/17/2018 12:00:00 AM	ADDRESS	34.09917	-118.32359	PC for power and energy for first time tenant office space. Installng new lights, receptacles and equipment. Total area 5871sqft. B#18016-10000-06780	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68477	11041-10000-16271	5522 W WILSHIRE BLVD 1st fl	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM			PC Approved	08/03/2011 12:00:00 AM	ADDRESS	34.06209	-118.34916	remodel showroom/officesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68478	13041-10001-00251	3364 W GARDEN AVE	90039	13	153B209   623	5437005002	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM			PC Approved	08/29/2013 12:00:00 AM	ADDRESS	34.11491	-118.25851	][][CHANGES MADE TO AN APPROVED SET OF PLANS; CUSTOMER UPGRADED THE SYSTEM SIZE FROM 3.43KW DC TO 3.57KW DC WITH THE USE OF ET SOLAR ET-P660255WB SOLAR MODULES, WHICH CARRY A HIGHER WATTAGE CAPACITY OF 255W COMPARED TO THE PREVIOUS MODEL 245W REC SOLAR REC245PE(BLK)][][][	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68479	17041-10000-13540	16200 W VENTURA BLVD	91436	5	168B137   450	2284003020	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.15647	-118.48571	Plan check for Title 24.  T.I. to 2nd, 3rd, and 4th floor of existing commercial office building.  Subpanels to remain existing.  New lighting and receptacles.  Total area = 2,472 sq. ft.     Building permit #16016-10000-23812	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68480	17041-20001-34876	7107 N PENFIELD AVE	91306	3	183B113   195	2135009027	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM			PC Approved	10/09/2017 12:00:00 AM	ADDRESS	34.19947	-118.56893	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.7 kWac and consists of (31) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68481	17041-10000-21954	4704 N DUNMAN AVE	91364	3	168B097   420	2074027040	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	Yes	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.15676	-118.62403	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68482	19041-10000-23643	3829 S BROADWAY	90037	9	117A203   251	5122038024	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.01336	-118.27776	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68483	16041-20001-14814	9913 N TUNNEY AVE	91324	12	201B117    71	2726013017	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.25044	-118.55807	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68484	12041-10000-09745	649 N BROADWAY BLVD	91436	1	133-5A215 147	5408016016	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	PIN	34.06001369	-118.23991457	New commercial office building.  Plan check and permit for Power and Energy.  ((Building permit has not been submitted yet.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68485	16041-30003-00371	14006 W RIVERSIDE DR #204	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Issued	06/16/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	06/16/2016 Changes to an approved set of plans. Changes include the addition of a new panel and revised loads. All changes have been clouded. *****Previous Work Description*****PC FOR POWER ONLY, TI IN A RETAIL SPACE. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES, TWO TRANSFORMERS AND NEW PANELS. CONNECTED LOAD IS > 400AMPS.  PC FOR ENERGY IS UNDER THE MASTER APPLICATION 16041-10000-00371. (((T-24, TI TO AN RETIAL SPACE INSIDE A MALL. SCOPE OF WORK INCLUDES NEW PANELS, LIGHTS AND RECEPTACLES. . TOTAL SQ. FT. 9545.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68486	12041-10001-09986	888 S FIGUEROA ST BASEMENT	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	05/14/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.0465	-118.26225	"Change to lighting to an existing office building.  PLAN CHECK is Only for Energy.  No emergency lighting.  Permit fees are under Inspection for new circuits and ""low-voltage""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68487	17041-10000-29756	200 WORLD WAY TMRL 2-STRG LV1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/21/2017 12:00:00 AM			PC Info Complete	08/24/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR STORAGE TI FOR TITLE 24, ENERGY ONLY. TOTAL AFFECTED AREA 400 sq.ftSCOPE INCULDES NEW PANELS, LIGHTS, EQUIPMENT AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68488	12041-10000-08628	2712-2714 S HOOVER ST	90007	8	123A201   259	5123001408	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			04/16/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.02987	-118.28376	remodel rooms on the first and second floors of an existing commercial building.new panelboards and circuyits;new lecture roomnew ada restroom on the forst floor and reeption room;remodel entrance area outside.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68489	16041-20000-11056	10936 N LINDLEY AVE	91344	12	210B125   614	2715021071	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.26955	-118.52553	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 175A.System size: 10kW. Ungrounded system. Each module has a 300W power optimizer. (30) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68490	13041-10000-31864	5005 S MAIN ST	90037	9	111A203   297	5110024028	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Apartment			11/14/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	12/16/2014 12:00:00 AM	ADDRESS	33.99714	-118.27431	Installing new addressable fire alarm system to new affordable housing apartment building.5 control panel,267 fire alarm devices, 1 fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68491	13041-10000-27572	8987 N LAUREL CANYON BLVD	91352	6	195B165   219	2629019012	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.2326	-118.40475	INSTALLING NEW FIRE ALARM SYSTEM FOR CORE AND SHELL 2-STORY COMMERCIAL BUILDING. SPRINKLERED SYSTEM, AREA OF WORK IS 11,000 SF.  31 DEVICES AND 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68492	19041-10000-27141	1063 W 31ST ST	90731	15	009B193   750	7469013024	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.71823	-118.30054	$0 permit fee per AB1414PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTIMIZERS. (11) MODULES AND OPTIMIZERS, (1) 3.8 SOLAREDGE EV CHARGER/ PV INVERTER. TOTAL SYSTEM SIZE IS 3.8 KWAC AND 3.63 KWDC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68493	18041-10000-03064	7901 N SEPULVEDA BLVD	91405	6	189B145   468	2222002020	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Issued	01/26/2018 12:00:00 AM	ADDRESS	34.21404	-118.4664	REPLACE EXTERIOR OUTDOOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68494	17041-10000-32757	6300 W WILSHIRE BLVD #720	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Info Complete	09/13/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	PC FOR T24 ENERGY ONLY. OFFICE TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68495	14041-20001-10265	7521 N LINDLEY AVE	91335	3	186B125   359	2119006014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.20728	-118.52748	Expedite per applicant requestPV1 roof-mounted system with (2) SE3800A-US-ZB-U transformerless inverters, (33) Canadian solar modules and total of 8.25kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68496	13041-10001-36313	627 N GRAMERCY PL	90004	4	141B193   749	5522007007	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.08254	-118.31275	Expedited RSES plan check per applicant request.{{PV1, Install 3.25 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (15) Modules: Trina Solar TSM-250PA05.18.(15) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68497	19041-20000-53280	8631 W 3RD ST suite 420	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/23/2020 12:00:00 AM		Permit Finaled	06/19/2020 12:00:00 AM	ADDRESS	34.07373	-118.38036	FULL PC FOR POWER AND ENERGY, SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER. TOTAL SQ. FT. 1729.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68498	11041-20000-06748	6635 N FALLBROOK AVE	91307	12	180B097   170	2038040005	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM			PC Info Complete	04/05/2011 12:00:00 AM	ADDRESS	34.18998	-118.6262	PLAN CHECK T24 ENERGY FOR TARGET RETAIL TI. LIGHTING ON EXISTING CKTS AND AREA CONTROL TO EXISTING LIGHTING CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68499	19041-10000-17613	10573 W SCENARIO LANE	90077	5	151-5A151 554	4380009022	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.1094	-118.44895	Permit fee is $0.00 due to AB1414.PV1 roof mounted 7.6 KWac/ 6.754KWdc, installing intergrated roof modules roughly 2100 sqft. Scope of work includes central inverter (Salivia 7.6) connected to a  200 A load center and a 13.5 KWH energy storage system , leading to a 200 A main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68500	14041-20000-16408	1232 N CORSICA DR	90272	11	129B133   145	4408002005	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Info Complete	08/13/2014 12:00:00 AM	ADDRESS	34.05102	-118.50326	New two-story family residence with 600A 120/240V 1ph-3w service.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68501	18041-10002-13489	3550 W WILSHIRE BLVD	90010	10	132B193    48	5093026***	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.06157	-118.30226	"PC FOR CHANGES TO APPROVED SET.SCOPE OF CHANGE INCLUDES RELOCATION OF ""MST-2"" FROM OUTDOORS TO INDOOR (BASEMENT) LOCATION IN BUILDING 3550 WILSHRE. THIS IS PLAN CHECK ONLY PERMIT PAID UNDER 10000.Installation of a 600A switchboard supplied from a service ( 17041-10000-38257) to provide temporary construction power. Permit for the circuits are not on this application"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68502	14041-10000-08657	3148 N FOND DR	91436	5	159B141   339	2293014012	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/07/2014 12:00:00 AM	ADDRESS	34.13179	-118.48338	PV1, INSTALL 10.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE6000A-US-ZB-U & SE3800A-US-ZB(42) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68503	14041-20000-10944	5341 N NATICK AVE	91411	4	172-5A149  87	2249018010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.16796	-118.45437	PV1.  Install 6.0 kW roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68504	15041-20001-06664	13224 MIRA MAR DR	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	PIN	34.31120672	-118.40409465	Supplemental application for changes to approved set.  Change from 24 modules to 20 modules.*****Previous Work Description*****PV1 SFD. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTER. USING STANDARD PLAN. TOTAL OF 24 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68505	10041-10001-25396	1219 W 27TH ST	90007	8	123B197  1288	5055026031	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.20	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.03041	-118.28714	Modification to a previously approved set of plans.  New smoke detectors, kitchen hood, bath fan.         <<<Bath and Kitchen remodeling (USC).  Install subpanels, branch circuits, and lighting.  Plan check for>>> power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68506	17041-10000-44935	11100 W SANTA MONICA BLVD 7th fl	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.04726	-118.44465	ALTERATIONS IN PUBLIC CORRIDOR/LOBBY AND RESTROOMSPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68507	13041-10000-32698	9000 N RESEDA BLVD BLDG B	91324	12	195B125   108	2769001022	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.23439	-118.53589	INSTALLING (2) NEW SERVICES TO (2) BUILDINGS ('A' AND 'B'). BUILDING 'A' IS NEW, AND BUILDING 'B' IS FOR A REMODEL TO EXISTING BUILDING. THIS APPLICATION IS FOR BUILDING 'B'. FULL PLAN CHECK FOR A NEW SINGLE STORY MULTI-TENANT RESTAURANT BUILDING - SHELL ONLY. THIS IS BUILDING . NEW 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68508	16041-30000-04635	1900 S SAWTELLE BLVD	90025	11	126B153  1450		C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Apartment			02/09/2016 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	04/12/2017 12:00:00 AM	ADDRESS	34.04236	-118.44464	Installation of fire alarm system in new 51 unit five story apartment building.  Total system size = 126 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68509	15041-20001-18571	12704 W WOODGREEN ST	90066	11	114B153   909	4246003015	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2015 12:00:00 AM			PC Approved	06/17/2015 12:00:00 AM	ADDRESS	34.00736	-118.44222	[[[6/17/15 changes to approved set of plans. plancheck only. changing from 3.8kw inverter to 3kw inverter only]]]]]Plan check for PV roof mounted system. System size: 3.8kW with 14 modules and 1 inveter (3.8kW).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68510	19041-10000-49517	604 E ROSE AVE	90291	11	111B145   964	4240011047	C4-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	33.99915	-118.47166	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68511	18041-10000-48545	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	02/06/2020 12:00:00 AM		Permit Finaled	04/22/2020 12:00:00 AM	ADDRESS	33.95887	-118.41869	T24 Energy plan check. Scope include new lighting and equipment with a total area of 1211-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68512	17041-10000-43205	1029 E VERNON AVE	90011	9	112-5A209  13	5115014032	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.00409	-118.25754	REMOVE OUTDOOR HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68513	13041-10000-16328	299 WORLD WAY	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Expired	08/01/2017 12:00:00 AM	ADDRESS	33.94454	-118.40534	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AT LAX. SINGLE TOWER FOUR FLOORS. SCOPE OF WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68514	13041-20000-29104	1930 E PACIFIC COAST HWY	90744	15	033B213  1562	7428007010	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	33.79122	-118.23803	Install new bio-diesel tank and pumps at Tesoro Logistics Terminal.  (Classified Hazardous Area)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68515	14041-20001-25358	17260 W RAYEN ST	91325	12	195B133   211	2690013012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.23207	-118.5107	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10.0KW INTERCONNECTED WITH MSP.( 50) TRINA SOLAR TSM-250 MODULES(2) ABB PVI-5000 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68516	14041-20000-34447	5682 W HOLLY OAK DR	90068	4	151-5A193  71	5587007019	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.11106	-118.31323	"""0$ fees due to senate bill 1222 ""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 13.5 KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68517	15041-20000-31519	3079 W SAN FERNANDO ROAD	90065	13	153A213    60	5458009018	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.11475	-118.24554	PLANCHECK FOR POWER AND ENERGY.  7- ELEVEN.  SCOPE OF WORK ONLY LIGHTING AND PANEL P. 2437 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68518	13041-20001-29392	13751 W HUBBARD ST	91342	7	222B153   124	2509014093	QR3-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.30578	-118.43247	(((EXPEDITE FEES)))PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 10.6 KW AC USING 36 MODULES. USING 2 CENTRAL TRANSFORMERED INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68519	11041-10002-10082	3724 E MISSION ROAD	90031	1	136-5A227  61	5211020021	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.06862	-118.20047	"DELTA (7) CHANGES TO APPROVED PLANS.  CHANGE FEEDERS TO PNLs ""A"", ""B"" & ""L"" FROM 4/0 TO 2/0. CHANGE THE FEEDER PROTECTIONS FROM 200A TO 175AMP.    New 7-11, TI, power, energy, lighting."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68520	13041-10000-31593	534 S MAIN ST	90013	14	129A211   253	5148020004	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.04577	-118.24914	POWER AND ENERGY PLAN CHECK FOR  A NEW MIXED USE BUILDING. NEW 7 STORY APARTMENT/RETAIL ( 2 LEVELS OF RETAIL ON THE BOTTOM AND 5 LEVELS OF APARTMENT). NOT A HIGHRISE ACCORDING TO APPLICANT.TOTAL OF 159 UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68521	19041-10000-16378	4716 W SANTA MONICA BLVD	90029	13	144B197   753	5538022002	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.09065	-118.2924	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68522	14041-10000-05589	19344 W RINALDI ST SUITE N	91326	12	210B117    25	2822019012	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.27346	-118.55532	Renovation of an existing commercial space for a nail salon and spa.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68523	19041-10001-38864	1472 W VERNON AVE	90062	8	111B193   172	5016002002	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.00358	-118.30263	"DELTA ""1"" changes to the approved plans for relocating the service equipment.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE  IS 5.58KWdc / 5.00KWac.(18)MODULES-CANADIAN SOLAR 310 W(18)OPTIMIZERS- SOLAREGDGE P320(1)INVERTER-SOLAREDGE SE 5000H-US)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68524	19041-20000-01545	9910 N BARTEE AVE	91331	6	201B157   115	2645006043	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.25051	-118.43188	PV1.  Install 8.12 kW DC / 7.6 kW AC roof mounted grid tied PV system with 9.8 kWh energy storage system.  (28) modules with 7.6 kW rated string inverter.  Critical load back-up panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68525	16041-20000-18363	6600 N TOPANGA CANYON BLVD System C	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for PV carport ground mounted system in Topanga Mall Parking Lot. System size:666kW with 3,071 modules and 20 inverters(33.3kW) This is system C.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68526	11041-10000-01049	2500 S NAVY WAY 2ND FL	90731	15	021B209   245	7440022909	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM			PC Approved	01/19/2011 12:00:00 AM	ADDRESS	33.73363	-118.2408	AT APM TERMINAL PIER 400, CONVERT OPEN SPACE TO OPEN  AND PRIVATE OFFICES  PERMIT WAS OBTAINED ON 10041-10000-25558PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68527	18041-30000-37458	6060 W CENTER DR 116A-116B	90045	11	102B169  7178	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			PC Info Complete	10/02/2018 12:00:00 AM	ADDRESS	33.97602	-118.39073	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT ON FIRST FLOOR TO CREATE TWO OFFICE ROOMS #116A AND #116B. TOTAL AREA: 240 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68528	17041-20000-37546	19615 W VALERIO ST	91335	3	186B117   625	2116003039	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.20443	-118.56039	Plan check for solar pv system, roof-mounted array on SFD.5.2kW ungrounded system. (22) 300W pv modules.Using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68529	15041-10000-27123	12460 W OSPREY LANE 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.9791	-118.40992	PV2 ROOF MOUNTED. TOTAL SYSTEM SIZE 1.84 KW ON COMMERCIAL 4-STORY BUILDING (BUILDING 8 UNIT 22) UNIT THREE(8) MODULES: SUNPOWER MODULES SPR-230NE-BLK-D(1) INVERTER PVI3.0 OUTD-S-US-A (POWER ONE) 240VACZONING CLEARANCES FOR UNIT 1,2, AND 3 INCLUDED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68530	12041-10000-14511	6330 W SAN VICENTE BLVD	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.06116	-118.36804	Plan check for energy and emergency lighting. 3350 sqft. Commercial low rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68531	16041-20000-44163	19347 W VENTURA BLVD	91356	3	174B117   294	2163001008	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM			PC Approved	12/15/2016 12:00:00 AM	ADDRESS	34.17288	-118.55519	Plan check for energy only. Change of use from retail to restaurant. New lighting (incl. emergency) in the kitchen area. 580sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68532	14041-20000-19131	5616 N FARRALONE AVE	91367	3	174B101   227	2146008255	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.17259	-118.61007	Changes from previously approved plans.  Change include relocate module on roof and inverter model number.*****Previous Description (14041-20000-17276)*****PC FOR PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN. CONNECTED TO 400A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68533	17041-20000-23461	1321 S WILSON ST	90021	14	121-5A215 224	5167004005	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM			PC Info Complete	08/02/2017 12:00:00 AM	ADDRESS	34.02574	-118.235	800 amp service upgrade to an existing commercial building. provide four empty panels with future loads.plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68534	18041-20000-40479	11272 W NEBRASKA AVE 1-24	90025	11	126B149   264	4261020002	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.04399	-118.44584	new 24 unit apartment building 1200 amp service.  plan check for power and energy.18010-30000-02317	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68535	18041-30000-36938	1800 S AVENUE OF THE STARS GRND FLR	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.06095	-118.41786	PC FOR AN EMPLOYEE BREAKROOM IN A EXISTING OFFICE SPACE AT GROUND FLOOR ( IN HIGH RISE BUILDING FOR T-24 ENERGY ONLY. TOTAL 190 SQ.FTB#18016-10000-03658	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68536	18041-20000-27676	4509 N SAN FELICIANO DR	91364	3	165B101   180	2076019015	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2018 12:00:00 AM			Reviewed by Supervisor	08/29/2018 12:00:00 AM	ADDRESS	34.15019	-118.61429	Plan check for PV roof mounted system, system size: 17.6kW AC with 54 modules and 2 inverters(10KW and 7.6KW) connected to MSP 400A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68537	13041-10000-00446	1835 S SEPULVEDA BLVD	90025	5	126B153   135	4323026019	M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.04494	-118.44233	REPLACEMENT OF 18 PACKAGE AIR CONDITIONING UNITS, ONE SLIT SYSTEM, THREE ROOF MOUNTED EXHAUST FANS AND TWO GAS FURNACE/EVAPORATIVE COOLERS. REPLACE LOCAL DISCONNECT SWITCHES AND REUSE/EXTEND EXISTING FEEDERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68538	14041-20001-01865	5865 N HILLVIEW PARK AVE	91401	2	174B157    59	2343020015	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.17701	-118.42642	(((EXPEDITE FEES)))pv1 single family dwelling. total system size 13.6kw ac using 59 modules and 3 transformerless inverters nonstandard plan.$0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68539	13041-20000-33082	1500 N EL CENTRO AVE	90028	13	148-5A189 331	5546026024	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM	04/02/2014 12:00:00 AM		Issued	04/02/2014 12:00:00 AM	ADDRESS	34.09961	-118.32359	New Below-Grade 5-level Parking Garage:  590,000 SF S-2 occupancy including B occupancy in accessory spaces (parking management office, building security office, etc.)New Six-Story Office Buildings:  10,150 SF A-2 occupancy (restaurant); 13,500 SF A-3 occupancy (fitness); 306,550 SF B occupancy (office); 2,100 SF M occupancy (retail)New Two-Story Office Building: 10,150 SF B occupancy (office)Future High-Rise Residential Tower: 1,800 SF A-2 occupancy (restaurant); 700 SF B occupancy (office); 6,000 SF M occupancy (retail); 245,600 SF R-2 occupancy (apartments)PC FOR POER AND ENERGY. PER BUILDING, COMMON PARKING, SINGLE STRUCTURE. 4 ADDRESSES.PLAN CHECK HOURS CHARGED DUE TO GLITCH IN PCIS. THEY ARE EQUIVELENT TO 213000 SQRFT OF TITLE 24 PLAN CHECK. TOTAL SQRFT FOR T24 IS 1,117,551 SQRFT. TOTAL PRICE OF SUBMITTAL IS ABOUT $60K	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68540	18041-20000-20197	5939 N CANOGA AVE	91367	3	177B105    87	2146006052	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.17815	-118.59772	Plan check for power only change of use to Outpatient Dialysis Center.  I Occupancy exempt from Title 24. OSHPD 3 PROJECT.B#18016-20000-16632	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68541	16041-10000-42087	1063 S WOOSTER ST 1-8	90035	5	132B169   422	4332016034	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			11/30/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	12/27/2021 12:00:00 AM	ADDRESS	34.05743	-118.38271	Plan check for new fire alarm system in a 8 unit 4 story buildig. Total fire alarm devices: 50 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68542	16041-20000-17158	5611 N FIGUEROA ST 3	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.10937	-118.19392	T.I. NONSTRUCTURAL INTERIOR REMODELING FOR CONVENIENCE STORE.  PLAN CHECK FOR POWER AND ENERGY.  1123 SQ FTBLDG PERMIT UNDER 16016-10000-09016	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68543	16041-10000-08098	700 N HIGHLAND AVE	90038	4	141B185   566	5524011014	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM			PC Info Complete	03/09/2016 12:00:00 AM	ADDRESS	34.08375	-118.33839	NEW METHANE GAS DETECTION SYSTEM TO A 4 STORY MIX-USE BUILDING. (11) DEVICES, POWER SUPPLY AND A GAS DETECTION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68544	16041-10001-06532	660 S FIGUEROA ST 1 & 6 flr	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM			PC Approved	12/06/2016 12:00:00 AM	ADDRESS	34.04953	-118.25947	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE USE OF DUAL CIRCUIT TYPE EXIT SIGNS CONNECTING TO GENERATOR CIRCUIT AND NORMAL CIRCUIT. CHANGE TO LIGHTING LAYOUT FOR FIRST FLOOR LOBBY AREA. UPDATED T24 DOCUMENT. THIS IS PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68545	18041-10000-40114	650 W 23RD ST	90007	1	123A203   146	5124028001	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.03136	-118.27574	PLAN CHECK FOR POWER AND ENERGY FOR POWER AND ENERGY FOR - CHANGE OF USE FROM RESIDENTIAL TO NEW OFFICE WITH ACCESSORY CLASSROOM AND CONFERENCE ROOM & MINOR STRUCTURAL UPGRADES. THIS IS AN ACCESSORY TO UNIVERSITY IN METHANE ZONE. BUILDING SERVICE = 400A WITH TOTAL AFFECTED AREA = 6486 SF.BUILDING PERMIT # 18016-10000-33950	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68546	19041-20000-16898	5227 N SHIRLEY AVE	91356	3	171B117   208	2164022007	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.1663	-118.55799	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS15.275 KW DC/11.4 KW AC. SCOPE OF WORK INCLUDES SE11400 INVERTER, (47) Q PEAK DUO PV MODULES WITH P370 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68547	11041-20000-22179	7818 N HILLARY DR	91304	3	189B093   548	2020003016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.21247	-118.64047	Plan check Enphase Mircoinverter 5.06KW photovoltaic system single family dwelling. Variance to install M215 prior to testing agency as been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68548	19041-10000-44374	1034 S MARIPOSA AVE	90006	1	129B197   366	5078016017	R4-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	03/25/2021 12:00:00 AM		Permit Finaled	04/08/2021 12:00:00 AM	ADDRESS	34.05169	-118.2988	TI IN AN EXISTING COMMERCIAL AREA. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.AFFECTED AREA: 990 SFT (INDOOR) & 4,807 SFT (OUTDOOR), TOTAL: 5797SFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68549	11041-20000-03386	1617 E 7TH ST	90021	14	124-5A215  54	5164023007	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	07/21/2011 12:00:00 AM	ADDRESS	34.03499	-118.23667	Plan check for new roof mounted 5.06KW Photovoltaic System at Charter School	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68550	17041-20001-28141	440 S CATALINA ST 1-42	90020	10	135B197   637	5502011020	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Apartment			08/09/2017 12:00:00 AM			PC Approved	10/02/2017 12:00:00 AM	ADDRESS	34.06619	-118.29524	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar system on apartment building.20kW ungrounded system (10+10). (77) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68551	18041-10000-25041	970 N MONUMENT ST STE 102	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.04646	-118.52393	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OPTOMETRY SPACE. TOTAL AFFECTED AREA IS 880 SQ. FT. B#18016-10000-21381	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68552	19041-10000-10727	5460 W FOUNTAIN AVE	90029	13	144B193   138	5537002027	R4-2	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Apartment			03/26/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	09/29/2021 12:00:00 AM	ADDRESS	34.09468	-118.30869	Power and energy plan check for a new 6-story,  49-unit apartment building over 2 level, Type IA, subterranean parking garage. Scope includes 1600A service. total affected area is 48,124 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68553	14041-10000-02456	2266 W 29TH ST	90018	10	120B189    64	5052020010	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	34.02897	-118.31675	PV1.  Install 5.18 kW AC roof-mounted PV system, interconnect with main service panel.  Upgrade of main service panel to 200A.  24 modules: Sun Module SW-255 Mono.  Microinverter standard plan: Enphase M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68554	10041-10000-14827	21811 W VENTURA BLVD	91367	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	10/08/2010 12:00:00 AM	PIN	34.16926375	-118.60275102	TENANT IMPROVEMENT AT A WAX CENTERPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68555	12041-10000-15100	140 E 22ND ST Warehouse-10	90007	9	121-5A205  34	5126033015	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	PIN	34.02870382	-118.26792905	Plan check for fire alarm system. 1 panel and 73 devices. Warehouse 10.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68556	15041-20000-09904	19509 W ARMINTA ST	91335	3	189B117   602	2105008002	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	04/17/2015 12:00:00 AM	ADDRESS	34.21356	-118.55848	Installation of new roof mounted solar PV array.  Total system size = 4.2 kWac.  Single inverter system with strings of 6 and 8 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68557	14041-10000-22168	1501 N MAIN ST	90012	1	136-5A217 147	5409003042	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	PIN	34.06690042	-118.22937525	Installation of new PV system and associated power conditioning equipment.  System size = 449.8 kWdc, 360 kWac.  18 inverters (20 kW each), 1384 modules (325 W each)PV SYSTEM IS PART OF DWP'S SOLAR GENERATOR PROGRAM IN WHICH THE SOLAR ENERGY  OBTAINED IS SOLD BACK TO THE UTILITY0$ PERMIT FEE IS IN ACCORDANCE WITH SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68558	12041-10000-18876	1875 E 22ND ST	90058	14	118-5A215 117	5167006013	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			08/15/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	04/24/2013 12:00:00 AM	ADDRESS	34.01661	-118.23726	Retrofit existing building lighting and power.  Remove and install new load and lighting to an existing warehouse building with office.  Plan check power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68559	16041-10000-38358	3507 S CLYDE AVE	90016	10	120B173   464	5047002043	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.02285	-118.36929	PV INSTALL 2.97 KW DC ROOF-MOUNTED  SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (11) MODULES: SUNEDISON SEF270KZD3Y(270)(1) INVERTER: SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68560	17041-10000-41249	8420 N BALBOA BLVD #113	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	"PC FOR RESAURANT TI  "" WABA GRILL"" IN A NEW BUILDING. SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1344 SQ.FT.B#17016-10000-33838"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68561	12041-20000-20880	23317 W MULHOLLAND DR	91364	3	168B093   181	2074001042	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			09/04/2012 12:00:00 AM			PC Approved	09/04/2012 12:00:00 AM	ADDRESS	34.15677	-118.63386	Plan check energy only. Plan for Karate Kids commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68562	13041-10000-34964	7814 N ORION AVE	91406	6	189B145   525	2222003003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2013 12:00:00 AM	12/24/2013 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.2125	-118.47044	PV1 6KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SMA 5000tl-us}]. [(20)modules: {phono solar 300W}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68563	16041-20001-40357	19548 W BALLINGER ST	91324	12	198B117    25	2761038009	RE15-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			PC Approved	12/02/2016 12:00:00 AM	ADDRESS	34.24327	-118.55991	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (47) modules, (47) micro-inverters, and (1) combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68564	19041-10000-19947	6951 S CENTINELA AVE	90045	11	105B165   931	4211011063	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	33.98326	-118.39974	pc (energy only) Interior alterations on ground floor of (E) training facility and new restrooms. area of scope is 7,161sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68565	13041-20000-28771	6600 N TOPANGA CANYON BLVD #183F	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Replacement of lights in an existing retail space.  No new circuits or loads.  PLAN CHECK ONLY FOR ENERGY, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68566	19041-10000-39679	410 S LINCOLN BLVD	90291	11	111B145   724	4243018031	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM			Reviewed by Supervisor	10/23/2019 12:00:00 AM	ADDRESS	34.00072	-118.46616	FULL PLAN CHECK PROPOSED ADDITION, TENANT IMPROVEMENT AND CHANGE OF USE FROM RETAIL/OFFICE TO RETAIL. SERVICE SIZE 600A,120/208V, 3PH, 4 WIRE. AREA OF SCOPE 3032SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68567	13041-10000-34759	1188 S SAN PEDRO ST STE #D	90021	14	124-5A211 297	5132012105	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/13/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	PIN	34.03375994	-118.25280059	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 812 SQ FT. TOTAL OF (5) UNITS WILL BE REPLACED. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68568	10041-20000-16055	9221 N CORBIN AVE Unit 105	91324	12	198B117   166	2761001073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	08/17/2010 12:00:00 AM		Permit Finaled	09/17/2010 12:00:00 AM	ADDRESS	34.23786	-118.56248	creating new office by putting dividing wall. P/C is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68569	17041-10000-32250	429 N HAYWORTH AVE	90048	5	141B177  1388	5527032022	R3-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Apartment			09/19/2017 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	07/28/2020 12:00:00 AM	ADDRESS	34.07898	-118.3629	FULL PLAN CHECK FOR A 4 STORY 16 UNIT APARTMENT BUILDING WITH A  1000AMPS SERVICE; TOTAL 8 TYPICAL UNITS. B#17010-10000-02561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68570	16041-10000-29704	1350 S ROXBURY DR	90035	5	132A165   286	4330013118	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			08/22/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.05471	-118.40246	Plan check for new Fire alarm system for Appartment building. Total fire alarm devices: 67 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68571	14041-10001-06674	3207 S SAN PEDRO ST	90011	9	118-5A207 425	5120020017	[Q]MR1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	11/04/2015 12:00:00 AM	ADDRESS	34.01676	-118.26466	Permit is issued under supplemental due to change of voltage.  Master application is plan check only.  Permit fee is under inspection period.This supplemntal plan check for change of design from 400 Amps, 480 volts to 800 Amps 120/240 delta, all floor paln and circuit reamin the same.  The permit to be obtained under master with number of circuits and equipment.Old submittal descroption--------PLANCHECK FOR POWER AND ENERGY FOR NEW AUTOMATIC CARWASH.  ( PLANS INCOMPLETE, SUBMITTED UPON APPLICANTS REQUEST. APPLICANT WAS INFORMED ABOUT ADDITIONAL FEES)new car wash---------	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68572	19041-10000-45542	21447 W MULHOLLAND DR	91364	3	165A105   175	2190002032	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.14574	-118.59946	(E-PLAN)NEW ROOF-MOUNTED PV1 INSTALLATION FOR A SERVICE OF 225 AMPS. INSTALLATION INCLUDES 33 MODULES (POWERXT-360R-PD), 33 OPTIMIZERS (P400), AND 1 CENTRAL INVERTER (SE11400H-US) SYSTEM SIZE: 11.88 KW DC;11.4 KW AC*NOTE 1: CONNECTED TO AN EXISTING PV SYSTEM*NOTE 2: MAIN SERVICE PANEL MUST BE PULLED ON A SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68573	16041-20000-34255	9201 N WINNETKA AVE	91311	12	198B113   208	2748039026	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Issued	12/12/2016 12:00:00 AM	ADDRESS	34.2374	-118.57146	PLANCHECK FOR POWER AND ENERGY PER APPLICANTS REQUEST. CHANGE OF USE FROM RETAIL TO FITNESS. ORANGE THEORY FITNESS.BUILDING PERMIT # 16041-20000-22553	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68574	16041-20000-19699	7222 N VAN NUYS BLVD #D	91405	2	183B149    37	2217003043	C2-1VL, QP-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.20187	-118.44851	TI to 219 sq ft (E) commercial space - take out restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68575	18041-30000-05393	100 WORLD WAY 1.5-Temp	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	12/14/2020 12:00:00 AM	ADDRESS	33.94572	-118.40095	Plan check for Temp Power  distribution LAX Project 5  SWA(South West Airline) Terminal 1.5 project.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68576	19041-10000-51979	10800 S BROADWAY	90061	8	088-5A203  35	6074011016	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	04/28/2022 12:00:00 AM	ADDRESS	33.93807	-118.27794	Replacing Existing outdoor HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68577	19041-10000-42114	13080 W PACIFIC PROMENADE	90094	11	099B157   479	4211021***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Approved	10/16/2019 12:00:00 AM	ADDRESS	33.97131	-118.42537	PLAN CHECK FOR INSTALLATION OF 18 NEW EV CHARGERS EACH AT 7 KW AND 3 NEW SUB PANELTOTAL LOAD: MORE THAN 400 AMPS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68578	18041-10000-14383	436 E 55TH ST	90011	9	108B205   614	5101003031	RD2-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	33.99235	-118.26606	Install New rooftop solar system, 5.36kW DC / 3.8kW AC. Scope includes (1) 3.8kW central inverter, (17) modules with (17) optimizers P370.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68579	18041-20000-10425	8501 N FALLBROOK AVE 1st Floor-Lobby	91304	12	192B097   587	2005022006	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.22478	-118.62651	Plan check for Title 24 only. Project site is the ground floor lobby of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,195 sq. ft.Note: Building permit has been issued under 18016-10000-02071	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68580	18041-30000-38032	1680 N VINE ST STE#1000	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.10133	-118.32648	PC FOR OFFICE TI IN HIGH RISE (10TH FLOOR) FOR T24 ENERGY ONLY. THIS IS AN HISTORIC BUILDING TO BE VERIFIED AN EXEMPTION FROM MADATORY EM. SYSTEM (GENERATOR). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 5064 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68581	13041-10000-28194	4912 N CARPENTER AVE	91607	2	168B169   137	2355013023	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/05/2013 12:00:00 AM	ADDRESS	34.1599	-118.3909	PV1.  Install 7.42 kW DC rofo-mounted solar array, interconnect with main service panel.  1 transformerless inverter w/ OP300 power optimizers.  28 modules: Suniva OPT-265-60-4	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68582	14041-20000-34955	12436 W SARAH ST	91604	2	168B165   924	2364015012	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2014 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.15384	-118.4043	Roof mounted PV system with system size 6.72KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68583	14041-20000-19746	8646 N CASABA AVE	91306	3	195B113   602	2781011010	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Expired	08/25/2016 12:00:00 AM	ADDRESS	34.22789	-118.57617	PV1.  Install 4.845 kW roof-mounted, utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68584	16041-10001-22323	405 N ALVARADO ST	90026	13	138A205   299	5157016029	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.10	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	34.07065	-118.26798	PC FOR (TI) to an (E) McDonalds for T-24 onlySUPP. DUE TO LOST SET OF PLANS. THIS IS PLANCHECK ONLY.PERMIT PULLED UNDER MASTER.  total area: 1884 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68585	16041-20000-36267	4640 N LANKERSHIM BLVD ste 125	91602	2	168B173   846	2421025021	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	34.15499	-118.36841	ti to an existing commercial building low rise.  adding new lighting new controls to existing panels.  plan check for energy and em lighting.  total square footage 4786.  scope of work to be performed in the first floor suite 125.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68586	18041-10000-04884	4574 S CENTINELA AVE	90066	11	108B157   887	4232026048	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	33.99165	-118.42143	Plan Check for energy only, T-24. Change of use from retail to coffee shop. Total sq. ft. 760.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68587	14041-20000-19704	2492 N ANGELO DR	90077	5	153B153    60	4382029***	RE15-1-H-RPD	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	Commercial			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.11584	-118.44368	PV1.  Install 5.0 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68588	10041-10001-23593	2110 W 7TH ST	90057	1	132A203   100	5141018002	C2-2	Central	Westlake	MacArthur Park		2094.02	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM			PC Approved	06/03/2011 12:00:00 AM	ADDRESS	34.0565	-118.27737	Delta 2 changes to the approved plan. (((((((((((((Change of use from retail to restaurant. EPC is for Power and energy.)))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68589	13041-10000-30520	2050 W JEFFERSON BLVD	90018	8	120B189   757	5042032001	C2-1VL-O-HPOZ, [Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.02542	-118.31654	Remove HID light fixtures and replace with new fluorescent fixtures in a church gymnasium.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68590	19041-20001-29065	22620 W AVENUE SAN LUIS	91364	3	171B097   517	2075010011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.16541	-118.61868	09-13-2019 Changes to an approved set of plan, Changes include relocate PV Modules on roof. Plan check only.Fees $0.00 Due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68591	17041-20000-42367	9841 N AIRPORT BLVD 10TH FLR	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Issued	11/22/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	PLANCHECK FOR T24 ENERGY.  TI TO COMMON COORIDOR AND RESTROOM UPGRADES. 2048 SQFT.  10TH FLOORBUILDING P# 17016-10000-18340	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68592	10041-10000-22513	520 S VIRGIL AVE SUITE #105	90020	4	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	12/22/2010 12:00:00 AM	ADDRESS	34.06457	-118.28687	"DEMISE AND CONVERT 35'-10"" X 36'-7"" PORTION OF (E) OFFICE SPACE INTO DOCTOR'S OFFICE.  INCLUDES INTERIOR NON-BEARING WALLS, CEILING SYSTEMS, MILLWORK AND FINISHES TO CREATE EXAM ROOMS, OFFICE, LUNCH RM AND WAITING AREA.  (1, 197 SF)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68593	14041-20000-11978	1712 W 252ND ST	90717	15	036B193   244	7410015051	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/02/2014 12:00:00 AM	ADDRESS	33.79561	-118.3081	PV1.  Install 3.97 kW roof-mounted PV system, interconnect with main service panel.  (11) Modules with (11) Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68594	18041-10000-20027	1624 S COTNER AVE	90025	5	129B149   233	4324035017	M1-1	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Issued	09/07/2018 12:00:00 AM	ADDRESS	34.04768	-118.44639	PC FOR WAREHOUSE TI FOR TITLE 24 ENERGY ONLY DUE TO REINSTALLATION OF SERVICE <400ASCOPE INCLUDES NEW LIGHTS AND T-24 FORMS TO COMPLY WITH 2016 CODE. TOTAL AFFECTED AREA 7591 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68595	19041-20002-27709	4335 W CEDARHURST CIR	90027	4	150B201    80	5591007007	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM			PC Approved	09/26/2019 12:00:00 AM	ADDRESS	34.11121	-118.28435	PLAN CHECK ONLY. Revisions to approved plans.  Adding utility-required disconnect for energy storage system. PERMIT PULLED UNDER 19041-20000-27709(((Plan check for power only. Project site is a single family dwelling. Project scope is the addition of a battery back-up unit to an existing PV1 roof-mounted PV system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68596	14041-20001-35920	5363 N BALBOA BLVD #121	91316	5	171B133    38	2258027016	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	34.16893	-118.50129	Changes to approved set.  Plan check for power and Title-24 (energy).  Total area = 1,600 sq. ft.T.I. to medical office.  Addition of 2 new panels and changes to lighting plan.Original submittal was checked for title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68597	15041-20000-03463	12180 W MILLENNIUM 4TH FLR	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN 4TH FLOOR.  TOTAL SQUARE FOOTAGE 12960.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68598	19041-20000-03813	8801 N GRESHAM PL	91304	12	195B101   236	2010008009	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.23003	-118.60498	Plan check for Battery energy storange system installed into existing PV System. Insatll 2 Energy Storage System Tesla Powerwall 2.0 9.8KWh. Total energy storage system: 27KWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68599	15041-10001-29087	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Issued	03/24/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	3/9/16: Changes to approved set under Delta-3: (1) Adding branch circuit to panel AA, AB, and GE    (2) install Temporary EM. lights to tenant space.   ***FULL PLAN CHECK FOR TENANT IMPROVEMENT; SCOPE INCLUDES ELECTRICAL WORK WITH NEW EQUIPMENT AND LIGHTING FROM LEVELS BASEMENT  THRU 2ND FL;  PLAN CHECK ONLY - PERMIT WAS PREVIOUSLY OBTAINED UNDER 14041-10000-09802 IN CONJUNCTION WITH APPROVED PLANS STAMPED BY PREVIOUS ENGINEER HIRED FOR PROJECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68600	13041-20000-08081	736 N EL MEDIO AVE PV-1	90272	11	129B125   679	4413015003	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.04656	-118.5332	PV-1. Plan check for PV system. 400A service with two 200A split busses. One 2.5kW inverter. Please include a 400A service upgrade for the permit fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68601	17041-20000-39372	10759 N HAYVENHURST AVE	91344	12	207B137   238	2683014019	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/27/2017 12:00:00 AM	ADDRESS	34.26641	-118.49368	PV1.  Install 3.68 kW roof mounted grid tied system.  (16) modules with microinverters.  Microinverter/ACM standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68602	16041-10000-17730	313 W 8TH ST	90014	14	127-5A209  91	5144014026	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	08/28/2017 12:00:00 AM	ADDRESS	34.0442	-118.25506	TI of (E) Retail facility due to Fire damaged. 600A service 240V,3-phase, Delta. Sign and Fire Alarm are not part of the scope. Some equipments are covered under the core and shell permit.**Note: Core & Shell portion of this project is under separate PCAM (E16LA01932).B# 16016-10000-08743 (core&shell), 16016-10000-11439 (TI).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68603	13041-10000-35259	1100 S SAN PEDRO ST #C08	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.03515	-118.25194	Plan check for T24 only. lighting fixtures, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68604	13041-10000-27272	8631 W 3RD ST 800-east	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.07373	-118.38036	pc for power and energy. new medical exam rooms. TENANT IMPROVEMENT FOR NEW MEDICAL OFFICE SUITE WITHIN EXISTING BUILDING.  NEW IMPROVEMENTS ARE LOCATED ON THE EIGHTH FLOOR AND TOTAL 9,452 S.F. 13016-10000-14905	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68605	14041-20000-16700	1935 W ADAMS BLVD	90018	8	123B193   556	5058019800	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	09/02/2014 12:00:00 AM		Permit Finaled	11/18/2014 12:00:00 AM	ADDRESS	34.03287	-118.30714	PC FOR TITLE 24 ONLY.  EXISTING COMMERCIAL BUILDING ADDITION OF THREE LIGHT FIXTURES ON ROOF TOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68606	11041-10000-12293	717 W 9TH ST	90017	9	129A207   265	5144021040		Central				2077.10	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	10/26/2011 12:00:00 AM		Permit Finaled	07/05/2012 12:00:00 AM				New restaurant.  First time tenant on the first floor of a high rise building.  Plan check is for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68607	17041-10000-36987	1460 W 27TH ST	90007	8	123B197  1350	5054032011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.03028	-118.29351	Install new PV2 on 2 separate structures of an multi unit apartment, total system 22.3kW AC. using (97) modules with (97) microinverters, (1) 200A load center. Permit fees are $0 due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68608	17041-10000-13360	433 S LAKE ST	90057	1	133-5A203   8	5154033022	R4-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.06195	-118.27487	T24 ONLY, REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 11160 SQ FT, OUTDOOR AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68609	12041-10000-21835	10908 W HARTSOOK ST	91601	4	171B173   830	2419002006	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.00	Electrical	Electrical	Apartment			09/13/2012 12:00:00 AM	09/13/2012 12:00:00 AM		Permit Finaled	02/14/2013 12:00:00 AM	ADDRESS	34.1634	-118.36851	PLAN CHECK CENTRAL FIRE SPRINKLER MONITORING SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68610	16041-20001-05414	11831 W FOLKSTONE LANE	90077	5	153B141   114	4378037079	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.1153	-118.47509	EXPEDITED PER APPLICANTS REQUEST.Install a solar array on a SFD. System size: 12.5 kWac, ungrounded system. (45) EnPhase M250 microinverters with (45) 285W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68611	17041-20000-39265	13775 N GLENOAKS BLVD	91342	7	228B145   795	2501015***	(Q)RD2-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.32191	-118.46864	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68612	13041-10001-29423	5345 N ARGUS DR	90041	14	165A225   102	5669003007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.14462	-118.20683	Expedited RSES plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68613	17041-10000-46587	5619 N LINDLEY AVE	91356	3	174B125   321	2157007063	RA-1	South Valley	Encino - Tarzana	Tarzana		1392.00	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Issued	12/29/2017 12:00:00 AM	ADDRESS	34.17299	-118.52746	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68614	14041-20000-17380	1100 S GLENDON AVE Ste 2100	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	12/17/2014 12:00:00 AM	ADDRESS	34.06074	-118.44418	TI to (E) commercial office suite in a commercial highrise building.  Plan check for TItle 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68615	13041-10000-19294	22957 W OXNARD ST	91367	3	177B097   457	2039016015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.17929	-118.62736	PV1 8.25kw XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [ 2 INV: PVI-3.6-OUTD-S-US and PVI-4.2-OUTD-S-US (transformerless)] [ 33MOD: TRINA {TSM-250PA05.08}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68616	11041-20000-24766	1700 W PICO BLVD	90015	1	127-5A203  66	5135020019	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	07/25/2012 12:00:00 AM	ADDRESS	34.04497	-118.27822	Convert an existing warehouse building into a school building (Charter School).  Note to plan check, the original plan submitted for review was replaced on December 14, 2011 with a revised plan showing a 480/277 service rated 600 amperes.  That revision accounts for descrepencies in the plan check fee indications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68617	15041-20000-01610	15943 W GRESHAM ST	91343	12	195B141   406	2672024013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2015 12:00:00 AM	01/30/2015 12:00:00 AM		Permit Finaled	03/13/2015 12:00:00 AM	ADDRESS	34.23112	-118.47994	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP.System size: 8.4kW (4.2+4.2). Ungrounded system.28  327W pv modules across 4 strings (2 per inverter).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68618	15041-10000-17013	12121 W WILSHIRE BLVD #600	90049	11	126B145   208	4264026055		West Los Angeles	BRENTWOOD			2643.02	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	PIN	34.04375344	-118.46845773	TENANT IMPROVMENT TO (E) OFFICE, REMOVE AND CONSTRUCT NEW NON-BEARING INTERIOR PARTITIONS.PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68619	14041-20000-24673	19716 W TRAMMELL LANE	91311	12	210B117   402	2701054020	RE20-1-H-K	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	ADDRESS	34.27191	-118.56333	FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222PV1.  Install 13.2 kW roof-mounted, utility-interactive PV system.  (2) 6 kW SolarEdge transformerless inverters with DC-DC converters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68620	15041-20000-20628	16333 W GLEDHILL ST	91343	12	198B137   147	2676010025	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.24213	-118.48841	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68621	17041-10001-34292	1630 W 186TH ST	90248	15	060B193   248	6108002022	P-1VL, [Q]MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	33.86187	-118.30705	Change of Note on sheet E101 indicating that ventaliation ( to exhaust the ceiling area at a rate of not less than 0.3m3/min//m2) will be provided regarding the ceiling area  as stated in NEC 511.3(B)(2)(a). Note that the pit is a Class I , Division I unless ventilation of a minimum of six air changes per hour.  Attached are pages from the NEC regarding 511.3 General area classification((((((PC for power and energy for hyrdrogen service garage (Hazardous location). Intalling new receptacle, vehicle service lifts, two panels and 45kVA transformer. Total area of 3070sqft. B# 17016-10000-27940.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68622	18041-10000-34874	21419-21421 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM			PC Approved	09/12/2018 12:00:00 AM	ADDRESS	34.2574	-118.5979	Energy plan check for a retail (salon) TI. Scope includes new lighting and equipment with a total area of 2,266-SQ FT. existing emergency lighting to remain (NO CHANGES TO BUG EYES)Note: portion of the permit fee is paid under 18041-10000-29211	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68623	15041-20000-38675	20700 W VENTURA BLVD Suite 100	91364	3	171B109    79	2166013017	(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.16656	-118.58435	Plan check for energy only. Change of use from health club (accessory to office) to beauty salon. TI of interior space. New lighting (incl. emergency) and receptacles. 8,253sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68624	19041-20000-45986	15301 W VENTURA BLVD 2ND FL	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.15411	-118.46654	T24 PLAN CHECK, LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 562 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68625	10041-20000-25697	3551 S TROUSDALE PKWY #160	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.02066	-118.28531	THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY FOR OFFICE SUITE #160 TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68626	13041-10000-12502	1572 W SUNSET BLVD	90026	1	139-5A209 202	5404020007	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.07651	-118.25727	13041 10000 12502NOTICES:1) investigation fee due.2) permit will expire 30 days from issuance datePC FOR ENERGY. TI TO EXISTING OFFICE OWNED BY BOFA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68627	10041-20003-04842	13164 W BURBANK BLVD	91401	5	174B157   656	2345005022	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	11/18/2010 12:00:00 AM	ADDRESS	34.17196	-118.4201	Delta 7 revisions to 02041-20000-12117. Changing outdoor fixtures, added receptacle loads, ckts, and changes to load calculation.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68628	17041-10001-00925	11250 W SANTA MONICA BLVD Lobby	90025	11	129B149   460	4261008022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM			PC Approved	08/17/2017 12:00:00 AM	ADDRESS	34.04661	-118.44736	SUPPLEMENTAL PLAN CHECK ONLY DUE TO FLOOR PLAN CHANGE. PC FOR ENERGY ONLY, T-24, TO AN (E) HOTEL LOBBY . PERMIT ISSUED UNDER MASTER# 17041-10000-00925	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68629	19041-20000-18131	20832 W PINECONE CIR 33	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	06/12/2020 12:00:00 AM	ADDRESS	34.29565	-118.58814	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68630	10041-10000-18100	6303 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM			PC Info Complete	09/13/2010 12:00:00 AM	ADDRESS	34.18474	-118.60182	Ti in an existing office. Plan check for T24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68631	13041-10001-29227	12101 W MARINE ST	90066	11	117B153   232	4248002020	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.01938	-118.44192	][][expedited per applicant request ][][]PV1, ROOF-MOUNTED SOLAR INSTALLATION INTERCONNECTING WITH EXISTING 200A MAIN SERVICE. MICROINVERTER SYSTEM DONE ON  NON-STANDARD PLAN. SYSTEM SIZE IS 3.9KW DC AND 3.225KW AC, WITH 15 MODULES (LG; LEG260S1C-A3) AND 15 ENPHASE M215 MICROINVERTERS ( M215-60-2LL-S2x) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68632	14041-20000-18386	8925 N MONOGRAM AVE	91343	12	195B137   292	2688011013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.23295	-118.49283	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(1) SOLAREDGE INVERTER SE6000(32) TRINA SOLAR TSM-255	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68633	18041-10000-12118	707 W WILSHIRE BLVD #3088	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.04893	-118.2572	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 3088 BUILDING PERMIT # 18016-10000-04003	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68634	10041-20000-25712	4600 W SPERRY ST	90039	4	165B201   177	5593007004	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Closed	07/06/2012 12:00:00 AM	ADDRESS	34.14823	-118.27596	New roof mounted P.V. system for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68635	14041-20000-13156	16201 W SAN FERNANDO MISSION BLVD	91344	12	210B141   409	2681011039	C2-1VL, P-1VL, QC2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.27207	-118.48535	New fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68636	19041-20000-21115	2727 S CLUB DR	90064	5	126B161    85	4308003006	R1V2-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.04209	-118.40577	Plan check for PV roof mounted system, PV system size: 19.14KW DC, 16.27KW AC with 58 PV Modules and 2 inverters(10KW) connected to existing 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68637	13041-10000-25449	1281 W 35TH ST	90007	8	120B197   706	5040021020	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			09/16/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.02463	-118.29685	PV1. ROOF MOUNTED SOLAR ARRAY.  SYSTEM SIZE: 12 KW ( 2 SNA SUNNYBOY SB3000, 1 SMA SUNNYBOY SB6000 ). 50 CANADIAN SOLAR CS6P-240P MODULES. 2 STORY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68638	16041-20000-31257	21860 W BURBANK BLVD #125	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.17198	-118.60379	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,106 sq. ft.Note: Building application has been created under 16016-20000-20391	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68639	16041-20000-36392	1036 S MAPLE AVE ste a	90015	14	126A209   304	5145019016	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	34.03739	-118.25473	remove existing hid fixtures and replace with new led fixtures indoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68640	17041-10001-34430	12105 W WATERFRONT DR	90094	11	105B161  1193	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	33.98095	-118.40764	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, ADDING/REMOVING PANELBOARDS, ADDING NEW CIRCUITS, AND REVISING LIGHTING FLOOR LAYOUT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68641	13041-10000-13513	11133 W ARMINTA ST	91352	6	189B173   332	2314007020	(T)RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.21399	-118.37383	PV1 ROOF MOUNTED SOLAR INSTALLATION USING TRANSFORMED INVERTERS ON NON STANDARD PLANS. SYSTEM SIZE IS 8.175 KW USING FIVE STRINGS OF 5 MODULES AND A SINGLE INVERTER. [MODULES: SUNPOWER # SPR-327NE-WHT-D |||| INVERTER: SUNPOWER # SPR-7501F]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68642	12041-10000-00974	25800 S WESTERN AVE	90710	15	033B193    53	7411004039	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.05	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	12/07/2012 12:00:00 AM	ADDRESS	33.78899	-118.3074	New Chevron Hydrogen Fueling Station Upgrade in a Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68643	11041-20000-20392	661 W REDONDO BEACH BLVD	90247	15	072B197    73	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	ADDRESS	33.89279	-118.28725	Plan check power and energy retail Staples TI to existing building. Variance to seperate fire alarm system has been filed. New 600A section supplying Staples. Existing 2000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68644	13041-10000-30205	948 S CROCKER ST UNIT #3	90021	14	124-5A211 204	5132002029	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.03501	-118.25004	REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. TOTAL AREA OF WORK TO BE 10240 SQ FT.NEW FIXTURES ARE SURFACE MOUNTED 4 LAMP FLOURESCENT WITH O.S.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68645	14041-10000-17605	837 E TRACTION AVE #400	90013	9	127-5A215  81	5163015005	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.04476	-118.2347	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT (E) OFFICE ON EAST PORTION OF 4TH FLOOR. ADDING 8 OFFICE SUITES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68646	15041-20001-25392	5525 N SEPULVEDA BLVD	91411	4	174B145   590	2250001035	C2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM			PC Approved	09/16/2016 12:00:00 AM	ADDRESS	34.17114	-118.46644	09/16/2016 Changes to an approved set of plans. All changes have been clouded and marked. Plan check is for Delta 2 only. Changes have been made to include new lighting for the back-of-house. All changes have been reflected onto the Title 24 compliance forms. *****Previous Work Descrition*****Plan check Title 24 only for existing restaurant Denny's. Total  indoor area: 3,548 sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68647	13041-10000-08837	9160 N VANALDEN AVE	91324	12	198B121   653	2762016058	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.23726	-118.54906	PV1 FOR SINGLE STORY HOUSE.  {52 MODULES: YINGLI YL245P-29B} {CENTRAL INVERTER: FRONIUS IG PLUSV 11.4-3}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68648	13041-10000-30915	14651 W COHASSET ST	91405	6	186B149   324	2218007003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.20675	-118.45264	PV1, Install 3 kW DC roof-mounted photovolatic system interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 12 modules: HANWHA # HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68649	13041-10000-13329	801 S HOPE ST	90017	14	129A209   178	5144020195	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.04656	-118.25938	FA - NEW INSTALLATION FOR A 22 STORY HIRISE. fees to be recalculated	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68650	13041-20000-00486	13838 W VENTURA BLVD	91423	4	165B153   593	2266018004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			01/08/2013 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.14836	-118.43443	fire damage. Plan check for energy only. single story retail. 3936 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68651	09041-10001-09114	10250 W SANTA MONICA BLVD B6	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM	03/17/2010 12:00:00 AM		Permit Expired	08/24/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	"Delta  8 revisions to approved set of plans for Tenant improvement - retail store, ""H&M,"" in mall. (PHASE 2 OF 2). Permit was obtained on09041-20000-09114. changes are new circuits for cash wrap receptacles. no changes in the lighting system."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68652	17041-20000-22068	8336 W MELROSE AVE	90069	5	141B173   494	5528015048	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM			PC Approved	06/29/2017 12:00:00 AM	ADDRESS	34.08342	-118.37151	Plan check for energy only. TI to commercial market. New lighting - 980sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68653	15041-20003-10807	18209 W PARTHENIA ST	91325	12	195B125   794	2769019041	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM			PC Approved	07/21/2016 12:00:00 AM	ADDRESS	34.2289	-118.52978	(7/21/2016)REVISIONS TO AN APPROVED SET OF PLANS.  REVISIONS ARE NOTED DELTA 3 ON PLANS.  THIS IS PLAN CHECK ONLY,  ALSO CHANGE OF CONTRACTOR.Plan check for power and Title-24 (energy).  Total area = 1,170 sq. ft. (unconditioned) + 5,630 sq. ft. (conditioned) + 1,000 sq. ft. (outdoor)Project is a new two story office building connected to new warehouse with common roof above a carport.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68654	18041-20000-04307	725 S FIGUEROA ST 30th flr	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/14/2018 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	ti to an existing commercial building (high rise).  adding new lighting new controls to ecxisting panels.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68655	16041-10000-45795	9301 N TAMPA AVE SUITE #177	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM			PC Info Complete	02/02/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	T-24, PC for energy only. tenant improvemtn for footlocker retail store. Scope includes new lights and receptacles. Total affected area is 5373 sq. ft. B#16016-30000-30099	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68656	16041-20000-22428	7845 N GOLL AVE	91605	6	189B169   965	2311011028	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.21337	-118.38191	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68657	19041-10000-37754	19030 W TRIBUNE ST	91326	12	207B121   166	2718014006	RS-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2019 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.26654	-118.54742	$0.00 fee due to senate bill 1222 and 1414[EPLAN] Revision to 190411000031143 Added Battery Disco under delta B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68658	13041-20004-29804	1500 W PACIFIC COAST HWY A-L	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			03/10/2016 12:00:00 AM			PC Approved	03/10/2016 12:00:00 AM	ADDRESS	33.79072	-118.2857	[[[[[ 3/10/16  CHANGES TO APPROVED SET.  REVISIONS TO FAULT CURRENT CALCULATIONS - CHANGE FROM 118 kA AVAILABLE FAULT CURRENT AT MAIN SERVICE TO PULL SECTION SPECIFIED BY DWP.  CHANGE OF MAIN SERVICE AIC RATING TO 100 kAIC AND MAIN SERVICE DISCONNECT RATING.  CLOUDED PORTIONS ONLY]]]]]BUILDING A:   NEW APARTMENT COMPLEX CONTAINING 12 SEPERATE BUILDINGS UNDER THE SAME ADDRESS. (2) 4000A SERVICES. PER APPLICANT REQUEST SUBMITTED AS ONE LUMP SUM. METHANE ZONE, HAS METHANE REPORT.Note: Variance to separate Methane Detection System has been filed.Permit Bld. B is under 14041-20000-06842Bld. C is under 14041-20000-06845Bld. D is under 14041-20000-06846Bld. E is under 14041-20000-06848Bld. F1 is under 14041-20000-06850Bld. F2 is under 14041-20000-06875Bld. G is under 14041-20000-06852Bld. H is under 14041-20000-06853Bld. I is under 14041-20000-06854Bld. J is under 14041-20000-06856Bld. K is under 14041-20000-06858Bld. L is under 14041-20000-06859Bld. Recreation is under 14041-20000-06860	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68659	19041-10000-01741	8762 N CORBIN AVE	91324	12	195B117   156	2783025095	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	06/14/2019 12:00:00 AM	ADDRESS	34.22956	-118.5621	TI IN AN EXISTING RETAIL SPACE. T-24 ENERGY ONLY.  3,533 SQR FT. BUILDING PERMIT: 18016-20000-37035	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68660	11041-10002-12901	1800 E OLYMPIC BLVD	90021	14	121-5A215  93	5166026036	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM			PC Approved	05/02/2012 12:00:00 AM	ADDRESS	34.02736	-118.23883	REVISED THE INTERIOR LIGHTING SYSTEM; changing luminaires to led type; obtain modification from Inspection section allowing existing feeders to cashier booth from new swbd CHANGE USE/OCCUPANCY:  Remodel of existing auto repair bays to new 7-11 Store.  Gas service to remain.  Canopy to remain.  EPC is for Power & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68661	12041-10000-05641	363 E 2ND ST	90012	14	129A215   378	5161017***	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	ADDRESS	34.04833	-118.24002	TITLE 24 ENERGY ONLY. STANDALONE BUILDING. EXISTING RETAIL SPACE. 411 SQFT. CHANGE LIGHTING AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68662	19041-20000-28974	18441 W MURAL PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	06/09/2021 12:00:00 AM				new sfd 600 amp service.  plan check for power only.  permit fees paid under building combo permit 18010-20000-05067.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68663	13041-10000-36169	1515 W WILSHIRE BLVD	90017	1	132A205   546	5142027034	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			12/30/2013 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.05498	-118.2688	PROPOSED  6 STORY, 218 UNIT MIXED USE RESIDENTIAL BUILDING OVER 1 LEVEL OF SUBTERRANEAN PARKING GARGE and GROUND FLOOR RETAIL , LOBBY AND PARKING BUILDING TO BE FULLY SPRINKLERED PER CBC SEC 903.3.1.1PLAN CHK FEES FOR ENERGY AND FIRE ALARM PLANS VARIANCE IS PENDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68664	18041-10000-32589	1015 S ABBOT KINNEY BLVD	90291	11	109-5A143 427	4286012001	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	33.99226	-118.4722	ENERGY STORAGE DEVICES BEING ADDED TO EXISTING PV SYSTEM. 40.5KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68665	19041-10000-36220	826 E 62ND ST	90001	9	105B209   166	6007011001	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	03/03/2020 12:00:00 AM		Permit Finaled	05/26/2020 12:00:00 AM	ADDRESS	33.98313	-118.2601	POWER PLAN CHECK FOR INSTALLATION OF A NEW 1600A  SERVICE 277/480V, 3PH, 4W. SCOPE INCLUDES NEW EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68666	18041-10000-34697	7517 S SEPULVEDA BLVD	90045	11	102B165   733	4110003085	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	33.9727	-118.39487	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68667	17041-10000-34975	1058 N AVALON BLVD	90744	15	033B205   889	7423006001	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	33.7845	-118.26257	REPLACE HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68668	14041-20000-21134	1680 N VINE ST Ste 1100	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.10133	-118.32648	TI to 11th floor office suite in (E) commercial highrise office building.  Use of battery backup for emergency egress lighting allowed per variance filed for permit app. 09016-10000-14109 presented by applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68669	18041-10000-11409	3377 W WILSHIRE BLVD #209-210	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.06193	-118.29742	SEE COMMENTSPC FOR (E) RESTAURANT TI. FOR TITLE24 ENERGY ONLY. SCOPE INCLUEDS NEW CIRCUITS, EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 2137SQ. FT.  B# 18016-10000-00128	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68670	14041-10000-35533	1662 S WELLINGTON ROAD	90019	10	126B185   372	5071004025	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.04358	-118.33153	"PV1 install 3.38 KW DC PV system roof mounted. 13 REC solar modules. 1 PVI-3.6-OUTD-S-US-A power one inverter. New 175 A main breaker. Center-fed. ""The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96 or approved plans by the LAFD""Submitted to plan check per applicant request. Eligible for online permit."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68671	13041-10000-23673	6831 W PARK GLENN DR	90068	4	153B181   590	5549031***	RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.11855	-118.34197	PV1 6.165KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: SOLAREDGE SE6000A-US] [( 27) MOD: Trina {TSM-245PC05.18} with optimizers {POWERBOX 250W OP250-LV-MC4SM-2NA}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68672	12041-10000-15844	1821 N WEEPAH WAY	90046	5	150A173   279	5567025018	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	08/13/2012 12:00:00 AM	ADDRESS	34.10603	-118.37393	Plan check new roof mounted Enphase M215 Mircroinverter photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68673	09041-20001-17801	16919 W VENTURA BLVD	91316	5	168B133    97	2258018002	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM			PC Info Complete	02/25/2010 12:00:00 AM	ADDRESS	34.15965	-118.50183	Adding additional lighting in hair salon. This P/C is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68674	14041-10001-02007	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			01/23/2014 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	34.10158	-118.3062	PV2, Install 81 KW DC roof-mounted solar array on a resturant and surrounding car ports, interconnect with main service panel.(8) Inverters: Fronius IG Plus V 11.4(270 )Modules: Canadian Solar MaxPower CS6X	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68675	19041-10000-34114	916 N WESTERN AVE	90732	15	021B193   192	7445011015	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	33.75076	-118.30886	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68676	18041-10000-35923	710 S WESTERN AVE	90005	10	132B193   376	5093007019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.05918	-118.3089	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68677	12041-10000-18055	5855 N VAN NUYS BLVD	91411	2	174B149    45	2244003021	(Q)P-1VL, (T)(Q)PB-1, C2-1VL, [Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	03/06/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	PIN	34.17716957	-118.44968879	TI IN AN EXISTING AUTO DEALER (KEYS TOYOTA). EPC FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68678	18041-10002-32591	1438 W 254TH ST	90710	15	036B193   526	7410006044	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	33.79368	-118.30248	SUPPLIMENTAL PERMIT TO COVER THE ADDITION OF A PULLBOX TO THE PERMITTED SOLAR SYSTEM. CHANGES ARE MARKED UNDER DELTA 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68679	19041-20002-13845	10700 N FULLBRIGHT AVE	91311	12	207B113    87	2707004019	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.26478	-118.57685	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. ADDITION OF A PERFORMANCE METER TO SINGLE LINE DIAGRAM, SITE PLAN, AND PLACARD PAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68680	18041-10000-24364	7044 N PENFIELD AVE	91306	3	183B113   269	2135010008	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.1987	-118.56865	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 4.20KWdc / 3.92KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER AND A METER ADAPTER. (14)MODULES-SOLARWORLD  SW-300(14)OPTIMIZERS-ENPHASE S280--60-LL-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68681	14041-10000-14887	12695 W SANDHILL LANE 1-3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/09/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	04/22/2015 12:00:00 AM	ADDRESS	33.97727	-118.41529	NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 23 DEVICES AND 1 PANEL. THERE ARE 12 ADDRESSES WITH THE SAME PLAN, EACH ADDRESS HAS ITS OWN APPLICATION AND PERMIT NUMBER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68682	14041-20000-00280	1000 N HIGHLAND AVE	90038	4	144B185   952	5532027014	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.08908	-118.33841	ALTERATION OF EXISTING 29000 SQRFT WAREHOUSE. PLAN CHECK FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68683	14041-20000-02636	5815 W SUNSET BLVD 404	90028	13	147A191    49	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM	02/06/2014 12:00:00 AM		Permit Finaled	03/07/2014 12:00:00 AM	ADDRESS	34.09822	-118.31613	PC FOR T24 ENERGY ONLY. TOTAL AREA 1860 SQ FT. EXISTING OFFICES WITH NEW LIGHTING.Only suit 404.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68684	17041-20000-01537	15260 W VENTURA BLVD SUITE 1430	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 1554 SQFT. HIGH RISE. SUITE 1430	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68685	11041-20000-07764	600 S MAIN ST	90014	9	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	07/21/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.04505	-118.24989	Fuse restaurant TI.  Power and energy.  New panels, recircuiting, and 150KVA transformer been added	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68686	14041-20000-09458	5017 N LAUREL CANYON BLVD	91607	2	171B165  1025	2356004017	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Apartment			04/09/2014 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.16172	-118.39681	600 AMP SERVICE. NEW CONSTRUCTION, 3-STORY APARTMENT WITH 4 UNITS.PLAN CHECK FOR POWER AND ENERGY.NEW 4 UNIT APTmodification for plan check extension filed 10-13- 15	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68687	13041-10001-32959	9927 N BABBITT AVE	91325	12	201B133    52	2694013026	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/29/2014 12:00:00 AM	ADDRESS	34.25112	-118.51014	Expedited RSES plan check per applicant request.[][]PV1, Install  7 kw DC roof-mounted solar array interconnect with service panel.Transformerless inverter: SOLAREDGE SE6000-US. 28 modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68688	15041-20000-10592	3479 N CAHUENGA BLVD	90068	4	159B177   338	2425024028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.13249	-118.35498	Plan check for Title 24 only. Project site is an existing commercial space (existing hair salon). Project scope is a tenant improvement. Total lighting area = 1,746 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68689	09041-10001-23701	6801 W HOLLYWOOD BLVD Suite 105	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM			PC Approved	04/30/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	TI for an existing retail space to a new restaurant, Hard Rock Cafe. Plan Check is for Title 24 Energy Calcs & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68690	14041-10000-11970	6255 W SUNSET BLVD 1040	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Expired	05/30/2016 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLAN CHECK FOR ENERGY ONLY FOR SUITE 1040 EXISTING OFFICE SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68691	18041-10000-46575	13030 N SAN FERNANDO ROAD	90049	11	222B145   117	2501006023	C1-1XLD, M2-1	West Los Angeles	Brentwood - Pacific Palisades	Sylmar		2643.02	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Closed	04/17/2019 12:00:00 AM	ADDRESS	34.04839	-118.49077	PLAN CHECK FOR TITLE 24 ONLY FOR CHANGE OF USE FROM RETAIL CLOTHING SALES TO BEAUTY SHOP TENAT IMPROVEMENT TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING. - 2612 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68692	19041-10000-46406	200 BAUCHET ST	90012	14	133-5A215 307	5409015027	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	12/14/2020 12:00:00 AM		Permit Finaled	03/31/2021 12:00:00 AM				FULL PLAN CHECK FOR NEW LADWP SUBSTATION, VOLTAGE CLASS IS 34.5KV, AREA OF SCOPE 960SF.******************************************************************************  BLDDG (16' X 60') TO SERVICE ADJACENT NEW DATA CENTER(UNDER SEPARATE PERMIT)******************************************************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68693	16041-10001-23008	5422 W CARLIN ST	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.03039	-118.3617	01/19/17CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED. CHANGES INCLUDE RELOCATING THE MODULES ON THE ROOF-LAYOUT, ADDING TWO ADDITIONAL MODULES, AND REVISING SINGLE LINE DIAGRAM. SPLITTING ONE STRING INTO TWO STRINGS.PV1, INSTALL NEW 3.445 KW DC ROOF-MOUNTED FOR A ONE UNIT OF A 3-UNIT BUILDING.(13) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68694	16041-20000-31874	11572 N COLLETT AVE	91344	12	213B141    83	2605021033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.28084	-118.48368	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter, (20) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68695	11041-20000-15251	13720 W RIVERSIDE DR	91423	4	168B157   318	2269025002	C2-1L, P-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/22/2011 12:00:00 AM	ADDRESS	34.15674	-118.43273	Ti in an existing retail. EPC is for T24 & emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68696	14041-20000-29284	1622 N WILCOX AVE	90028	13	148-5A187 245	5546007006	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM			PC Info Complete	12/09/2014 12:00:00 AM	ADDRESS	34.10042	-118.33085	***VOID**** change engineerSYSTEM UPGRADE TO 800 AMPS.  EXISTING THREE STORY HOTEL BUILDING.  PLAN CHECK FOR POWER AND ENERGY. 9332 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68697	10041-10000-12062	6609 N FALLBROOK AVE	91307	3	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.19025	-118.62372	TENANT IMPROVEMENT  AT RETAIL STORE TJ MAXX	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68698	15041-20000-32729	9734 N KENTLAND AVE	91311	12	201B101   308	2727003026	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Expired	11/01/2017 12:00:00 AM	ADDRESS	34.24725	-118.61786	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (22) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68699	17041-10000-42501	10250 W CONSTELLATION BLVD 23RD FLOOR	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	FULL FLOOR  INTERIOR OFFICE TI TO INCLUDE: NON BEARING PARTITION WALLS,;NEW PANELS; NEW CIRCUITS AND LIGHTING FIXTURESFULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68700	17041-20000-41840	935 E COEUR D'ALENE AVE	90291	11	108B149  1071	4237019008	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	33.99205	-118.45222	pv1install roof mounted pv system sized 3kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68701	19041-10000-24427	9736 N MARCUS LANE	91042	7	201A201   332	2564016051	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.24532	-118.28231	PV1 Roofmounted system system size is 5KWac/6.55KWdc. Scope of work is 23 modules (Hanwha Q-Cell Q Plus 285) with optimzers (SE P320) and a central inverter (SE5000H-US) .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68702	15041-10001-33974	3308 E 3RD ST	90063	14	124-5A227 228	5179012031	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2016 12:00:00 AM			PC Approved	01/06/2016 12:00:00 AM	ADDRESS	34.03521	-118.19788	Supplemental to an approved set. Change the orientation of the Meter, AC disconnect, and Inverter. Permit under 15041-10000-33974**** new roof mounted 7.6 KW solar PV array on existing single family dwelling.  Total systems ize = 7.6 kWac.  Central inverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68703	18041-20000-36576	362 W 13TH ST	90731	15	015B201   758	7456009021	RD1.5-1XL-CPIO	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	33.73253	-118.28495	Plan check for a PV1 roof-mounted PV system. System size is 5.22 kWdc/7.6 kWac and consists of (1) inverter, (18) modules, (1) transformer, (1) load center, and (1) battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68704	16041-20000-27959	7600 N BALBOA BLVD	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/08/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	34.2087	-118.50093	Plan check for power and energy. Project site is an existing commercial building. Project scope is a core and shell for a 2-story addition to an existing 1-story building. Work includes a new 2500-amp service and associated distribution boards. Total lighting area =  11,440 sq. ft.Note: Building permit has been issued under 15014-20000-05283	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68705	16041-10000-21183	3751 W WILSHIRE BLVD	90010	10	132B193    29	5503030017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM			PC Info Complete	06/16/2016 12:00:00 AM	ADDRESS	34.06186	-118.30818	T-24, PC FOR ENERGY ONLY. TI  TO AN (E) RETAIL PHARMACY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 980 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68706	17041-10000-09179	835 W BLOOM WALK #163	90089	9	118-5A201  22	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.01948	-118.2876	Plan check for Title 24 only in existing space T.I. Total area: 665 sq ft,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68707	16041-20000-05208	215 N VERMONT AVE	90004	13	138B197   568	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Apartment			02/12/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Closed	10/12/2017 12:00:00 AM	ADDRESS	34.07493	-118.29195	$0 permit fees due to senate bill 1222Plan check for PV roof mounted system. System size: 112kW with 276 modules and 8 inverters(14kW) connected to 400A sub panel	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68708	13041-20000-28135	4703 E DEL PASO CT	90032	14	135A231    47	5215029012	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	12/04/2013 12:00:00 AM	ADDRESS	34.06545	-118.18341	PV1 TRANSFORMERLESS SYSEM. TOTAL SYSTEM SIZE 13 KW. 40 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68709	19041-20000-52394	20140 W SHERMAN WAY	91306	3	183B113    63	2135038015	(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	09/23/2020 12:00:00 AM		Permit Finaled	01/16/2021 12:00:00 AM	ADDRESS	34.20085	-118.57213	PV3.  Install 186 kW DC / 167.9 kW AC-CEC roof mounted PV system.  (465) modules with (7) 20 KW inverters and a 150 kVA transformer.$0 permit fee per State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68710	16041-10000-00512	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	REVISIONS TO PERMITTED SET OF PLANS-RELOCATED IT ROOM T7-7229 AND UUTILITY ROOM 7229-1   PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68711	12041-10000-28677	216 S ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM			PC Approved	11/29/2012 12:00:00 AM	ADDRESS	34.04645	-118.23792	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN A BATHROOM 1193 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68712	10041-20000-23480	6467 N LANKERSHIM BLVD	91606	2	180B169   896	2322017071	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	08/02/2011 12:00:00 AM	ADDRESS	34.18847	-118.38798	"Plan check power and energy for new laundromat with 1200A service. Modification to seperate fire alarm system has been filed. ""COMPLY WITH DEPARTMENT ORDER DATED 09/17/2003. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68713	10041-20000-21522	13488 W MAXELLA AVE	90292		105B153    78	4212004012	[T][Q]RAS4-1-CDO		Palms - Mar Vista - Del Rey	Del Rey			Electrical	Electrical	Apartment			10/28/2010 12:00:00 AM			Corrections Issued	01/03/2011 12:00:00 AM	ADDRESS	33.98592	-118.44252	temporary power	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68714	18041-10000-32127	6150 N LAUREL CANYON BLVD BLDG H	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	11/16/2020 12:00:00 AM	ADDRESS	34.18223	-118.39491	New Fire Alarm System for two buildings H and J. Plans were combined per fire department. Inspection fees for Building J are under application # 18041-10000-34660 / E18LA04070.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68715	09041-10001-24462	3051 E WABASH AVE CELL 1	90063	14	129A227    13	5229028035	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2032.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM			PC Approved	02/18/2010 12:00:00 AM	ADDRESS	34.0495	-118.19533	POWER FOR CELL SITE. permit obtained on 09041-10000-24462plan chk is for title 24 compliance	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68716	15041-10000-34888	1017 N LAS PALMAS AVE 3RD FL-RESTROOM	90038	4	144B185   896	5532026036	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.08943	-118.33642	ALTERATIONS INSIDE RESTROOMS ONLY FOR OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68717	19041-10000-41341	1358 N WILCOX AVE	90028	4	147A187   310	5546017904	PF-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	05/21/2020 12:00:00 AM	ADDRESS	34.09584	-118.33083	PLAN CHECK FOR POWER ONLY - PLAN CHECK INCLUDES 800A DISTRIBUTION SERVICE PANEL  CONNECTING TO AN EXISTING SYSTEM FOR NEW CAR CHARGERS	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68718	18041-10000-46807	700 S FLOWER ST S220	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	Full plan check per applicant request.Full plan check for a change of use from retail to a beauty salon in Suitye #230. Scope includes new lighting and (2) new panels with a total area of 2,080 SQ FT.Bld permit 18016-10000-39546	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68719	17041-10000-23048	1925 S CENTURY PARK EAST 1900	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.06066	-118.41426	PC FOR TENANT IMPROVEMENT TO (E) OFFICE IN A HIGH RISE FOR TITLE-24 ENERGY ONLY. SOCPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 2273 SQ.FT.BL# 17016-10000-16698	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68720	12041-20000-14541	6141 W PICO BLVD	90035	5	129B173    23	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	11/01/2012 12:00:00 AM	ADDRESS	34.05336	-118.37538	Change of use from retail to CHASE bank.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68721	12041-10000-30745	12959 W CORAL TREE PL	90066	11	102B157    34	4211008024	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	33.97747	-118.42395	PLAN CHECK FOR FIRE ALARM .INSTALLATION OF MANUAL FIRE ALARM SYSTEM IN COMMERCIAL BUILDING. (<150 DEVICES)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68722	16041-20000-22645	8907 N DE SOTO AVE #8907	91304	3	195B109    57	2779002032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.23198	-118.58872	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR HALA KAUSAR MEAT MARKET. 1300 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68723	14041-20000-00509	9449 N BIANCA AVE	91325	12	198B129    34	2766019003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Closed	02/09/2016 12:00:00 AM	ADDRESS	34.24276	-118.5143	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 6.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68724	18041-20000-18989	4462 W COLLEGE VIEW AVE	90041	14	157-5A219  36	5473031039	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.12774	-118.22219	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (24) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68725	16041-10000-30142	1654 S GREENFIELD AVE 1-8	90025	5	129B153   553	4324030010	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.04935	-118.4417	Plan check for new Fire Alarm System in new appartment building 8 units. Total fire alarm  devices: 64 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68726	13041-10000-16726	9242 N ANDASOL AVE	91325	12	198B129   266	2766013027	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.23906	-118.51329	Roof-mounted 14.7KW photovoltaic System. USING 60 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68727	16041-10001-31820	2010 E 7TH ST	90021	14	124-5A217 259	5166015004	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.03441	-118.23187	THIS APPLICATION IS REVIEW T24 FOR ENTIRE TENANT SPACE. NO OTHER CHANGES. PERMIT ISSUED UNDER MASTER. THIS IS PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68728	19041-20001-03857	17171 W ARMSTEAD ST	91344	12	213B133   181	2607015054	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.28288	-118.50729	Void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68729	17041-10000-21256	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.30363	-118.45814	T24 ONLY - REPLACEMENT OF EXISTING LIGHT FIXTURES WITH (34) LED FIXTURES.  TOTAL AFFECTED AREA =  83275 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68730	14041-20000-35909	3041 N DONA MARTA DR	91604	2	156B173   114	2380023012	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.12675	-118.37871	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 100A MSP.System size: 3.36kW. Ungrounded system.14 EnPhase M250 microinverters with 14  250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68731	17041-20001-42144	5414 N WAMEDA AVE	90041	14	165A227   196	5691018019	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	11/27/2017 12:00:00 AM	ADDRESS	34.14471	-118.19494	expeditepv1install roof mounted pv system sized 10kw AC/ 12 kw DC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68732	12041-10000-00695	8500 W BEVERLY BLVD #750	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/11/2012 12:00:00 AM			PC Approved	09/20/2012 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT OF TWO (E) RETAIL SPACE AND COMBINE TOGETHER: LIGHTING FIXTURES; MODIFICATION OF (E) ADA UNISEX RESTROOM; NO CHANGE IN USE. PLAN CHK IS FGR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68733	15041-20000-38786	15313 W CABRITO ROAD	91406	6	189B145   331	2654037025	R4-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Apartment			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/27/2017 12:00:00 AM	ADDRESS	34.21591	-118.46699	Install new fire alarm system in a anew 4 story apartment build. 69 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68734	16041-20000-28728	20236 W HEMMINGWAY ST	91306	3	189B113  1382	2107011100	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21386	-118.57427	Plan check for a PV1 roof-mounted PV system. System size is 5.6 kWac and consists of (20) modules, (20) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68735	17041-20002-14697	12370 N TELFAIR AVE	91342	7	219B145   492	2604032026	RE9-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM			PC Approved	05/17/2017 12:00:00 AM	ADDRESS	34.29518	-118.46073	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.97 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68736	12041-20000-14363	15836 W CELTIC ST	91344	12	210B141   958	2667012015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	08/01/2012 12:00:00 AM	ADDRESS	34.26897	-118.47737	Roof mounted P.V. system for dwelling.  Install 34 modules, one box with installed fusing, and one inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68737	16041-30000-08084	444 S FLOWER ST 43RD FLOOR	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/08/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only in existing high-rise building. total area:	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68738	10041-10000-02559	18303 W KITTRIDGE ST	91335	3	180B125   381	2125017017	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			02/12/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	11/10/2011 12:00:00 AM	ADDRESS	34.19034	-118.53214	NEW PV SYSTEM IN THE BUILDING. 1 @ 7.5 KW & 1 @ 6 KW INVERTERS WITH 84 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68739	12041-20000-10903			5	171B129   463	2290004001	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM			PC Approved	05/11/2012 12:00:00 AM	PIN	34.16089221	-118.51223389	Plan check for energy and emergency lighting. Single story commercial. Ti for a retail space. 1017 conditioned sqft.Permit is express on number 12041-90000-04290((adding outlets in new partition walls, change out existing light fixtures, add circuits to new utility room for equipment.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68740	19041-10000-14518	9764 N NATICK AVE	91343	7	201B149   385	2650016004	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.24767	-118.45286	*Zero permit fee per AB-1414/ SB-1222*[EPLAN]  (LOST ORIGINAL PLAN) CHECK FOR PV/ENERGY STORAGE SYSTEM WITH REQUIRED DWP DISCONNECT - PV PERMIT 19041-90000-17005ENERGY STORAGE SYSTEM 18041-10002-08932	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68741	10041-20000-08229	19413-19415 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	ADDRESS	34.18711	-118.55558	Lighting and power in retail store. This plan check is for energy only. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. SEE COMMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68742	16041-20000-24647	5901 W CENTER DR 1-281	90045	11	102B169   963	4104023017	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Closed	07/03/2019 12:00:00 AM	ADDRESS	33.97509	-118.38703	Plan check for Temporary Power Service 1,200A on 5 story Building.Building Application number: 07010-10000-04319	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68743	17041-20000-37497	4800 W WILSHIRE BLVD	90010	4	132B185    22	5507030001	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.06182	-118.33508	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,381 sq. ft.Permit pulled on supplemental 17041-20001-37497Note: Building permit has been issued under 15016-10000-25090	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68744	13041-10000-03270	888 S OLIVE ST	90014	9	127-5A209 127	5144018047	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Closed	09/30/2014 12:00:00 AM	ADDRESS	34.04383	-118.25785	NEW 800A TEMP SERVICE.  for the construction of NEW 32 STORY APARTMENT, MIX USE.POWER FOR CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68745	15041-10001-30305	2211 W CAMBRIDGE ST	90006	10	126B193   101	5074010011	R2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.03	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	34.04464	-118.30652	Expedite per applicant requestPV1 6KW AC roof-mounted system with (20) Sunpower SPR-327-NE modules and (1) Power-One PVI-6000-OUtd inverter interconnecting through the main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68746	14041-20000-01254	16167 W ROYAL OAK ROAD	91436	5	162B141   175	2286013008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2014 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.14143	-118.48363	Modification to previously approved set of plans to relocate equipment on the same exterior wall.  Original permit is on 13041-20000-22450       <<<PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 27KW AC. ROOF MOUNTED. TOTAL OF 90 MODULES. USING TRANSFORMERLESS INVETER NONSTANDARD PLAN>>>.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68747	15041-10000-34429	9920 S COMPTON AVE	90002	15	091-5A213 123	6048016002	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	33.94608	-118.2461	PV1, INSTALL NEW 2.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY.(10) MODOULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68748	10041-10000-01244	285 W 6TH ST	90731	15	015B201   133	7455021921	C2-2	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			01/25/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	33.73849	-118.28317	PLAN CHECK POWER AND ENERGY FOR CHANGE OF FROM RETAIL TO OFFICE.  PLAN CHECK IS FOR POWER & ENERGY FOR FIRST TIME OCCUPANCY.  BUILDING PERMIT WAS PROCESSED UNDER 09016-10000-16709 AT 630 S. CENTRE ST.  THE CORRECT ADDRESS FOR THIS BUILDING MUST BE VERIFIED BY THE APPLICANT BEFORE ELECTRICAL PERMIT CAN BE ISSUED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68749	15041-10001-33450	5422 W CARLIN ST #1	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			Reviewed by Supervisor	10/20/2015 12:00:00 AM	ADDRESS	34.03039	-118.3617	EXPEDITED RSES PLAN CHEK PER APP;ICANT REQUEST.<<<PV1, INSTALL NEW 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE UIT OF AN APARTMENT BULDING.(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.0-OUTD-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68750	16041-10001-30260	157 S FAIRFAX AVE	90036	5	138B177   716	5511025012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM			PC Approved	09/13/2016 12:00:00 AM	ADDRESS	34.07256	-118.36158	09/13/16Changes to an approved set of plans. All changes are made under delta 1. Changes include removing/adding lighting fixtures on floor plan. Note: Original application is under PCIS#16041-10000-30260(((((PC for energy only. TI on 1st floor of a 2 story existing office/wholesale building.  Installing new lighting and power. Total sqft = 1472	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68751	17041-10001-25386	1521 S 2ND AVE	90019	10	126B189   126	5072035005	RD1.5-1-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.20	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.04469	-118.31908	PC FOR ROOF MOUNTED PV ON AN APARTMENT BUILDING. SYSTEM SIZE 4.8KW DC 3.8 KW ACSINGLE INVERTER SYSTEM WITH 16 MODULES.THIS IS PALN CHECK ONLY!!!Permit pulled under master	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68752	15041-20001-05894	4200 S OLIVE ST	90037	9	114A203   123	5111007025	RD2-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM			PC Approved	04/17/2015 12:00:00 AM	ADDRESS	34.00723	-118.27932	Expedite per applicant request.((((Plan check for PV1 roof mounted 8.1kW with 36 module microinverters.)))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68753	16041-10000-24895	325 W ADAMS BLVD	90007	9	121-5A205 132	5126018032	(T)(Q)C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Apartment			07/15/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.02712	-118.27319	NEW PV2 ROOF MOUNTED SYSTEM. SYSTEM SIZE IS 442KWAC.1650 MODULES (SUNENERGY CSUN305-72P) AND 19 INVERTERS (FRONIUS SYMO 24.0-3 & 10.0-3)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68754	19041-10000-46001	10823 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			11/09/2019 12:00:00 AM	07/13/2020 12:00:00 AM		Permit Finaled	11/23/2020 12:00:00 AM	ADDRESS	34.2668	-118.52366	POWER PC FOR INSTALLATION OF (16) TESLA EV CHARGING STATIONS. SERVICE RATED 2500Amp 480/277 3� 4W. SCOPE INCLUDES INSTALLATION OF NEW PANELBOARD & EV CHARGING EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68755	15041-10000-15354	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015037	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	INSTALL NEW FA SYSTEM WITH  446 FA DEVICES AND 9 FA PANEL  . 6-STORY ABOVE GROUNDWITH TWO SUBTRRANIN PARKING LEVEL. UNDER GROUND.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68756	19041-10000-49052	10610 N LA CANADA PL	91040	7	207B185   547	2549016011	(Q)C2-1VL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Issued	12/31/2019 12:00:00 AM	ADDRESS	34.2608	-118.33951	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 15.84KWdc (14.4KWac) USING 48 VBHN330SA17 MODULES, 48 SE P400 POWER OTIMIZERS, 1 SE-3000H-US & 1 SE-11400H-US CENTRAL INVERTERS. CONNECTED TO A 225 AMP NEW SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.Zero fees are in affect due to senate bill AB1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68757	14041-10000-05703	12418 W HAVELOCK AVE	90066	11	105B161   127	4221023024	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/16/2014 12:00:00 AM	ADDRESS	33.98737	-118.41742	PV1, INSTALL 3.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(15) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: POWER-ONE AURORA PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68758	10041-10000-11743	815 W COLORADO BLVD 2nd & 3rd-floors	90041	14	163-5A231 110	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM			PC Approved	06/21/2010 12:00:00 AM	ADDRESS	34.14051	-118.18382	INTERIOR TENANT IMPROVEMENTS 2ND & 3RD FLOORS CORRIDORSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68759	18041-10000-47841	1808 W 7TH ST	90057	1	132A203   226	5142006900	C2-2	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Issued	12/18/2018 12:00:00 AM	ADDRESS	34.055	-118.27394	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68760	18041-10001-13605	4544 1/2 W MELBOURNE AVE	90027	4	150B197  1173	5590022003	R2-1XL	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.10348	-118.28904	EXPEDITE PER APPLICANT REQUEST----------------------------------------------------------------------------------------------------------NEW ROOFTOP SOLAR SYSTEM ON TWO INTERCONNECTED SINGLE FAMILY DWELLING UINITS ( 1 AND 1/2). (2 OF 2) CONSIST OF  8 MODULES ( EAGLE MP 60B- 285W), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS 320) WITH A CENTRAL INVERTER (SOLAR EDGE SE 3800H-US).  SYSTEM SIZE IS  2.28 KWdc AND 3.8 KWac.(1 OF 2) # 18041-10000-13596	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68761	13041-20000-05333	2391 N ROSCOMARE ROAD 1-10	90077	5	153B145    35	4378018002	RD2-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Apartment			03/01/2013 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.1187	-118.46392	10 UNITS APARTMENT BUYILDING. Four habitable stories (high-rise residential per energy code). Units 1B and 3B occupy two floors each, all other units are single-story. Fire Alarm Variance has been filed. Not methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68762	14041-20001-01962	1816 S SHERBOURNE DR	90035	10	126B169   160	4303023004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	02/27/2014 12:00:00 AM	ADDRESS	34.04468	-118.38108	(((EXPEDITE FEES)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68763	19041-20000-42535	15301 W VENTURA BLVD 300	91403	4	168B145   821	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Issued	10/18/2019 12:00:00 AM	ADDRESS	34.15411	-118.46654	TENANT IMPROVEMENT ADD NEW LIGHTS PLAN CHECK FOR TITLE-24 ONLY. TOTAL AFFECTED AREA 20,617 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68764	16041-20002-22609	380 W WORLD WAY NORT	90045	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	PIN	33.95178495	-118.42609814	6/27/17changes to an approved set of plans.  changes noted delta 2.  changes include addition of 1 light fixtures.  revised energy calculations.address change from 8100 westchester parkway. Plan check for energy.  TI to currency exchange store.  263 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68765	10041-20000-15010	13488 W MAXELLA AVE	90292		105B153    78	4212004012	[T][Q]RAS4-1-CDO		Palms - Mar Vista - Del Rey	Del Rey			Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM			PC Info Complete	08/18/2010 12:00:00 AM	ADDRESS	33.98592	-118.44252	Plan check T-24 Energy (general/emergency) lighting for interior TI for FEDEX Office store. New load less than 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68766	14041-20002-23980	4024 N RADFORD AVE	91604	2	165B169   716	2368005011	[Q]M2-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.14441	-118.39252	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3 ON PLANS. NEW 2KVA TRANSFORMER. NEW 800AMP SERVICE FOR 5 STORY TYPE2A OFFICE AND GARAGE BUILDING.(2 STORIES PARKING, 3 STORIES OFFICES.PLAN CHECK FOR POWER AND ENERGY.PLAN CHECK IN ACCORDANCE TO 2008 ENERGY EFFICIENCY STANDARDS DUE TO BUILDING SUBMITTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68767	16041-20000-13178	9570 W PICO BLVD 1ST FL	90035	5	132A167   257	4306002022	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.05499	-118.39734	Plan check for Title 24 only. Project site is the first floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,633 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68768	18041-10000-06229	3883 S 3RD AVE	90008	10	117B189  1183	5034016030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.0152	-118.32048	Install New PV1 rooftop solar system, 5kW AC system. (18) modules with power optimizer, and (1) central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68769	18041-10000-15718	2250 S MAPLE AVE	90011	9	121-5A207 259	5127014037	[Q]CM-2-O	South Los Angeles	Southeast Los Angeles	South Central		2264.10	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.02599	-118.26368	PLANCHECK FOR POWER AND ENERGY. OFFICE AND WAREHOUSE.  55345SQFT.BUILDING PERMIT # 17014-20002-02323SUPPLEMENTAL TO 17014-10000-02323 TO EXTEND (E) 2ND FLOOR AND ADD 9,232 SQFT FOR OFFICE/STORAGE WITHIN (E) HIGH CEILING BUILDING. SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68770	18041-10001-29178	960 N LA BREA AVE	90038	4	144B181   634	5531015004	(Q)M1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Info Complete	01/27/2020 12:00:00 AM	ADDRESS	34.08868	-118.34386	PLAN CHECK FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDES REVISIONS TO LIGHTING LAYOUT, ADDITION OF MOTOR LOADS AND CHANGES TO POWER FLOOR PLAN. TOTAL AFFECTED AREA 57750sqft. ALL CHANGES ARE CLOUDED UNDER DELTA 5. ORIGINAL PC BY MEHDI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68771	19041-20001-49044	17436 W NAPA ST	91325	12	192B129    31	2787034006	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Issued	12/30/2019 12:00:00 AM	ADDRESS	34.22669	-118.51416	INSPECTION FEE UNDER PERMIT NUMBER 19041-90000-49044PV1. INSTALL 9.24 KW DC ROOFMOUNTED PV SYSTEM WITH (28) MODULES AND MICROINVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68772	17041-20000-21069	15260 W VENTURA BLVD ste 1550	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.15356	-118.4658	ti to an existing comercial building.  Adding new lighting new controls to existing panels.  plan check for energy only.  suite 1550.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68773	15041-10000-43734	22840 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.18624	-118.62454	TI TO RETAIL SPACE. NEW DISTRIBUTION EQUIPMENT AND LIGHTING. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68774	17041-20000-43252	9527 GLORY AVE	91042	7	198B201   186	2572039010	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	Yes	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	PIN	34.24086904	-118.28002593	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (23) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68775	10041-10000-23804	13238 W RIVERSIDE DR	91423	12	168B157   341	2358032040	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	02/18/2011 12:00:00 AM	ADDRESS	34.15742	-118.42172	TI IN AN EXISTING COMMERCIAL AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68776	19041-10000-14748	1630 W SEPULVEDA BLVD #100-Star Bucks	90710	15	045B193   498	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	ADDRESS	33.81654	-118.30809	New Starbuck's Rest. (Unit #100) connected to an existing 1600 Amp Service. Plan Check for Power & Energy. Shell Only. Complete Plan Check will be required fr the TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68777	19041-20000-21564	18750 W HART ST	91335	3	183B121   567	2126017004	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.19748	-118.54226	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 7.5KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (25) LONGI GREEN PV MODULES WITH P320 OPTIMIZERS, AND A SE7600A-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68778	18041-10000-33414	1314 W COURT ST	90026	1	135A209   210	5160011017	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Info Complete	11/02/2018 12:00:00 AM	ADDRESS	34.06415	-118.25713	METHANE DETECTION SYSTEM WITH 15 METHANE SENSORS AND 1 METHANE CONTROPL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68779	16041-10001-26342	10400 S AVIATION BLVD	90045	11	090B173   318	4129034001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	33.94154	-118.37829	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES  INCLUDE COMPLETE FEEDER SIZING, REPLACING FEEDER BREAKER, REVISING VOLTAGE DROP, LOAD CALCULATIONS, SIGHT LIGHTING, ADDING NEW TRANSFORMER, AND ONE NEW AIR COMPRESSOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68780	19041-10000-09134	21042 W SAN JOSE ST	91311	12	207B105   631	2706019030	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.2607	-118.59264	PV1. New solar system on existing residential rooftop . Total system size is 11.685 KWdc / 10.0 KWac. Scope includes 41 modules, optimzers and one central inverter	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68781	17041-10000-26529	3600 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Issued	08/22/2017 12:00:00 AM	ADDRESS	34.13829	-118.34154	PC for fire alarm system with 37 devices , one fire alarm panel and one annunciator panel in single story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68782	16041-20001-08649	8820 S SEPULVEDA EASTWAY	90045	11	096B165   920	4123006025	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Apartment			03/15/2017 12:00:00 AM			PC Approved	03/15/2017 12:00:00 AM	ADDRESS	33.95623	-118.3946	"[[3/15/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA ""E"" and ""F"" CHANGES ONLY. CHANGES ARE CLOUDED. CHANGING FEEDERS FROM COPPER TO ALUMINIUM AND CHANGES TO T24 LIGHTING ]]Plan check for new 136 units apartment.  5 stories with 2 stories of subterranean parking."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68783	15041-20000-17091	333 S GRAND AVE 10th FL	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			PC Approved	06/03/2015 12:00:00 AM	ADDRESS	34.05271	-118.25179	Plan check for Title 24 only office T.I. Wells Fargo at 10th floor. Total area: 20,490 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68784	18041-20000-26573	1540 E ALCAZAR ST #110D	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.06338	-118.20434	Plan check for Title 24 Energy only in existing office suite T.I. Total area: 704 sq ft. B#18016-10000-21560	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68785	15041-10001-01161	7125 N RIVOL ROAD	91307	12	183B089   138	2028037016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.20023	-118.6545	Installation of new solar PV array.  3.6 kWac transformerless system.  Applicant tried to pull permit online but couldn't.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68786	10041-20000-08695	6600 N TOPANGA CANYON BLVD #38	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check power and energy for retail TI at Westfield Topanga Mall (Suite#38)  REF.#10042-10000-10468.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68787	19041-20000-46046	3952 N ALOMAR DR	91423	4	162B157   600	2385007016	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.14025	-118.4206	SERVICE UPGRADE TO 600A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68788	15041-10000-32087	6134 W VENICE BLVD	90034	10	123B173   306	5065012071	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.03521	-118.37735	TI TO AN EXISTING GARAGE.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD < 400 AMPS PLAN CHECK FOR ENERY AND EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68789	18041-10002-09060	5722 W JEFFERSON BLVD	90016	10	120B173   311	5047018002	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM			PC Info Complete	05/08/2018 12:00:00 AM	ADDRESS	34.02588	-118.36994	TI INSIDE AN EXISTING OFFICE BUILDING. SUPPL APP PLAN CHECK FOR PHOTOMETRIC CALCS FOR EMERGENCY LIGHTS ONLY.T-24 WAS APPROVED AND PERMIT WAS ISSUED UNDER 18041-10000-09060B# 17016-10000-33624	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68790	18041-10000-15007	500 E TEMPLE ST	90012	14	130-5A215 333	5173009901	[T][Q]C2-2D-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.05028	-118.23532	PC FOR TENANT IMPROVEMENT TO EXISTING OFFICE SPACE ON FIRST FLOOR. SCOPE INCLUDES NEW LIGHTS ONLY. TITLE-24 ENERGY ONLY.TOTAL AFFECTED AREA 739 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68791	17041-20000-33686	7456 N KELVIN AVE	91306	3	186B109   474	2113010025	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	01/13/2018 12:00:00 AM	ADDRESS	34.20632	-118.58611	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (26) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68792	16041-20001-09497	7440 N SEPULVEDA BLVD	91405	6	186B145   417	2221005001	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			03/22/2016 12:00:00 AM			PC Approved	04/25/2016 12:00:00 AM	ADDRESS	34.206	-118.46584	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 66.6 kWac and consists of (2) inverters, (228) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68793	17041-20000-37274	4721 N KRAFT AVE	91602	2	168B169   632	2354013063	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.15636	-118.38022	ADDITION TO AN EXISTING PV SYSTEM . PV1. ROOFMOUNTED. SYSTEM SIZE: 4.2 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68794	17041-20001-22140	13938 W BURTON ST	91402	6	192B153   902	2213003004	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.22059	-118.43695	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.11.34kW ungrounded system.(42) EnPhase S280 microinverters.(42) 315W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68795	12041-10000-07105	8517 N VALLEY FLORES DR	91304	12	193-5A091  62	2017022022	A1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2012 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	ADDRESS	34.22462	-118.64938	NEW ROOF MOUNTED 20.1 KW PV SYSTEM ON A SINGLE FAMILY HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68796	10041-20001-11058	15206 W PARTHENIA ST Building 1	91343	7	195B145   535	2654041001	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills			1175.20, 1175.30	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	ADDRESS	34.2281	-118.46381	Plan check power for existing medical office (Building 1).  Disconnect existing service and install new 800A service and refeed exsiting existing equipment/panels. Service supplying new Building 2.  Plan includes plan check for Building 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68797	18041-20000-49206	1880 S CENTURY PARK EAST STE 510	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/31/2018 12:00:00 AM	01/02/2019 12:00:00 AM		Permit Finaled	02/08/2019 12:00:00 AM	ADDRESS	34.06144	-118.41437	Plan check for Title 24 only in existing space interior tenant improvement to  suite 510. Total area: 870 sq ft. B#18016-40000-40894	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68798	16041-20000-45172	5121 N WINNETKA AVE	91364	3	171B113   309	2166010008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2016 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.16392	-118.57148	PV1.  Install 13.68 kW roof mounted grid tied PV system.  (48) modules with microinverters.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68799	17041-10000-00965	2406 E 8TH ST	90021	14	123A217   371	5166007012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Approved	01/11/2017 12:00:00 AM	ADDRESS	34.02944	-118.22948	PC FOR ENERGY ONLY, ELECTRICAL T.I.: ADD 100A PANEL (20) NEW CIRCUITS AND NEW LIGHTING. INSPECTION FEES HAVE BEEN PAID UNDER EXPRESS PERMIT 16041-10000-30169. PC ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68800	18041-10000-28134	4867 W SUNSET BLVD	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Los Feliz	Yes	1912.01	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/29/2020 12:00:00 AM	ADDRESS	34.09832	-118.29564	PLAN CHECK FOR POWER FOR - INSTALL OF A FUEL CELL GENERATOR WITH CONCRETE PADS - SYSTEM SIZE = 3600KVA CONSISTING OF 12 FUEL CELLS(BLOOM ENERGY - 300KVA EACH)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68801	14041-10001-30016	672 E 120TH ST	90059	15	084B205  1197	6086026021	RD2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	33.9235	-118.26268	PV 2 ROOF MOUNTED SOAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 3 KW 7 MODULES WITH 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68802	17041-20001-12245	6932 N GROSS AVE	91307	12	183B093   567	2028013004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM			Reviewed by Supervisor	04/26/2017 12:00:00 AM	ADDRESS	34.19499	-118.64003	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68803	15041-20001-05467	342 N FLORES ST	90048	5	138B173   227	5514009006	R1-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2015 12:00:00 AM			PC Approved	04/13/2015 12:00:00 AM	ADDRESS	34.07726	-118.37093	CHANGES TO APPROVED SET OF PLANS. PLANS NOW SHOWS CORRECT MOUNTING HARDWARE. NO OTHER CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68804	19041-20000-18920	10509 W CAMARILLO ST pv1	91602	4	168B177   481	2420004016	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.15781	-118.35961	pv1install roof mounted pv system sized 10KW AC interconnected with msp.(2) tesla powerwalls ESS at 5KW AC each	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68805	12041-20000-26264	11570 W HARTSOOK ST	91601	2	171B169   522	2354004025	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	34.16387	-118.38464	Plan check due to sump pump being a Class I Division 2 area.INSTALLING A SUMP PUMP SYSTEM IN A SINGLE FAMILY HOME FOR EMERGENCY DRAIN ONLY. NO ROOF (RAIN) WATER AND/OR SITE DRAINAGE IS ALLOWED INTO THIS (SUMP PUMP) SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68806	17041-10000-23801	912 S 4TH AVE	90291	11	108B145   604	4239010022	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			07/14/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	33.99357	-118.47151	PV2. NEW SOLAR SYSTEM FOR AN EXISTING MULTI-FAMILY RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(7)MODULES-TRINA SOLAR#TSM-300DD05A.18(1)INVERTER-ABB#PVI3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68807	19041-10000-13290	17431 W MINNEHAHA ST	91344	12	207B129   972	2733022036	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.26046	-118.51456	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 29 MODULES (LG325N1C) AND 29 MICROINVERTERS (ENPHASE IQ7-60-X-US).  SYSTEM SIZE IS 9.96KWdc and 7.25KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68808	12041-10000-29015	6900 S VERMONT AVE	90044	8	102B197   669	6013005806	C2-1VL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			12/04/2012 12:00:00 AM	07/10/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	33.97704	-118.29132	INSTALL FUEL CELLS WITH 1200A MAIN BUS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68809	18041-10000-48934	400 S SOTO ST	90033	14	126A223   106	5185001021	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.04019	-118.2118	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68810	15041-10000-10269	1140 S ORLANDO AVE	90035	5	132B173   897	5087009008	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.05598	-118.37375	Install new 8.82 kw dc roof-mounted solar array on a single home family, tie with main service panel.(27) modules: sunpower spr32ne-wht-d(2) inverter: sma sb5000tl-us-22 & sb3800tl-us-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68811	18041-20000-36403	1249 S GRAND AVE	90015	14	126A207   160	5139022018	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.03937	-118.2645	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a first time tenant. Total lighting area = 880 sq. ft.Note: Building application has been generated under 18016-20000-24862	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68812	15041-20000-00982	8759 W SKYLINE DR	90046	4	153B169   364	5564009013	RE15-1	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2015 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.11539	-118.38572	PV1. Install roof mounted PV system sized 6.48 kW. Interconnected with main service pannel.(27) Solarworld SW 280 modules(27) Enphase M250 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68813	15041-20000-27497	13165 N LA TIERRA WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Expired	09/08/2017 12:00:00 AM	ADDRESS	34.312	-118.40433	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (13) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68814	16041-10002-12055	1315 E M ST	90744	15	033B213    43	7425019022	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	33.78944	-118.24745	05/04/16Changes to an approved set of plans. All changes are made under delta 3. Changes include relocating the pv modules on the roof, relocating the main service equipment to the detached garage, and changing module type from Hyundai His-M250 to Hyundai His-M255. New total system size is 2.00KWdc / 1.72KWacNote: permit paid under pcis# 16041-10000-12055(((((PV1 INSTALL 1.72 KW AC ROOF-MOUNTED SOLAR ARRAY FOR A UNIT WITHIN A 3 UNIT APARTMENT PER SINGLE LINE. (8) MODULES: HYUNDAI HIS-M250-MG(8) MICROINVERTERS: ENPHASE ENERGY M215-60-2LL-S22-IG	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68815	17041-10000-44658	1025 S STANFORD AVE	90021	14	124-5A211 328	5132009019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.03336	-118.24926	Plan check for new fire alarm system for wholesale mart.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68816	14041-20000-10446	937 N CITRUS AVE	90038	4	144B181   680	5532011034	[Q]MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/21/2014 12:00:00 AM			PC Info Complete	12/24/2014 12:00:00 AM	ADDRESS	34.08825	-118.33978	New 1600 service, service equipment, and feeders for existing building.  Reconnect the existing subpanels to the new service.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68817	15041-10000-34617	3101 E 12TH ST	90023	14	118-5A223  67	5169005006	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.01907	-118.21312	Title 24 plan check only.  Total area = 2,359 sq. ft. (conditioned) + 17,412 sq. ft. (unconditioned)  T.I. to existing commercial space.  New open office.  Most space has new lighting but is otherwise left undeveloped.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68818	11041-20000-26305	633 W 5TH ST 48th fl	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM	12/09/2011 12:00:00 AM		Permit Expired	01/02/2014 12:00:00 AM	ADDRESS	34.05099	-118.25468	add power supply to existing system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68819	12041-10000-09904	4411 S 11TH AVE 1-143	90043	8	111B185   119	5013022030	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Public Safety Only			05/01/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.00327	-118.32948	REPLACING FIRE WARNING SYSTEM -NEW FA PANEL AND DEVICESEXCEPT FOR THE FIRST FLOOR, EACH FLOOR IS WIRED SIMILARLY-SAME NUMBER OF DEVICES AND POWER SUPPLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68820	18041-20000-00995	728 N LA BREA AVE	90038	5	141B181   449	5525008040	C4-1VL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Closed	03/03/2018 12:00:00 AM	ADDRESS	34.08433	-118.34386	ti to an existing commercial building.  adding new lightingnew controls to new panels.  newly connected load <400 amps.  plan chek for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68821	11041-10000-01933	10366 W WILSHIRE BLVD 1-9	90024	5	135B157   139	4327013***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Public Safety Only			02/01/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.06722	-118.42766	INSTALLATION OF A FIRE WARNING SYSTEM FOR A 9-UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68822	15041-20001-33019	3350 W WILSHIRE BLVD	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.0615	-118.29586	plancheck only.  Revisions to approved set. changes are clouded.  Changes to service details and emergency system capacity - and associated SLD revisions.  Lighting control scheme changes.  Appliance load VA changes to match installation.  (((CONVERSION OY 12-STORIES/BASEMENT OFFICE/GARAGE TO 216 ADAPTIVE REUSE UNITS AND RETAILS ON THE 1ST FLOOR.BLDG PERMIT 13016-10000-26033)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68823	12041-10000-03664	175 S FAIRFAX AVE #A	90048	5	138B177   750	5511026008	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/17/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	PIN	34.07185666	-118.36174302	PLAN CHECK 24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT ON EXISTING RETAIL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68824	16041-20001-24815	17954 W RINALDI ST	91344	12	213B125   437	2715018042	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	07/27/2016 12:00:00 AM	ADDRESS	34.27903	-118.52542	Expedite per applicant request{{{{Plan check for PV roof mounted system. System size: 12.0kW with 59 modules and 2 inverter(6.0kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68825	17041-20000-03933	15760 W VENTURA BLVD suite 110	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighitng.  total square footage 2842.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68826	14041-20001-01959	14936 W HARTLAND ST	91405	6	183B149   662	2220018008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.19517	-118.45876	(((EXPEDITE FEES)))PV1 MICROINVERTER NONSTANDARD PLAN. ADDING 1 STRING TO AN EXISTING SOLAR SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68827	16041-20001-45349	9045 W ORIOLE WAY	90069	4	147B169   770	5560004013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.09694	-118.38765	expedite per applicant.pv1addition to an existing pv system.  installing roof mounted pv system sized 7.6kw iterconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68828	16041-10000-31930	10250 W SANTA MONICA BLVD # 1710	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	01/18/2017 12:00:00 AM		Permit Finaled	05/16/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Sephora"" Ste. 1710.  Install 150KVA Xrfmr, new panels and its circuits, total effected area: 7,965 sq.ft.*New demand load 246 A from DB ELA40"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68829	10041-10000-25334	108 S CROFT AVE 1-6	90048	5	138B173   639	5511014004	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.07419	-118.37407	New fire alarm system. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68830	16041-30000-13615	2000 S AVENUE OF THE STARS 1ST FL	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.05868	-118.41546	Title 24 plan check only.  Total area = 580 sq. ft.     T.I. to two offices in commercial highrise building.  Six new lights and 4 new receptacles total.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68831	13041-10000-16437	750 S LAMAR ST SWITCH CRW-SHANTY	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (10.)  SWITCH CREW SHANTY. 1 SWITCHBOARD SECTION. PREFABRICATED BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68832	15041-20000-03280	8106 N BEVIS AVE	91402	6	189B149    73	2210004005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2015 12:00:00 AM	02/03/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.21818	-118.45602	PV1. ROOFMOUNTED SYSTEM. ADDITION TO EXISTING SOLAR SYSTEM. SYSTEM SIZE: 3 KW TOTAL SIZE: 6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68833	19041-20000-21360	20700 W SESNON BLVD #176	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	Plan check for a PV1 roof-mounted PV system. System size is 5.25 kWdc/4.725 kWac and consists of (15) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68834	14041-10000-30044	333 S ALAMEDA ST	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.04448	-118.23824	Little Tokyo Galleria Facade RenovationPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68835	13041-20000-04631	18245 W VINTAGE ST	91325	12	204B125   330	2731023034	RA-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	34.25195	-118.53123	Enphase system on roof of single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68836	17041-10000-39217	6301 S NORMANDIE AVE	90044	8	105B193   984	6002033044	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.98219	-118.30045	PC for T24 only for removal of HID fixtures and repalcement with LED fixtures. Total of 30475sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68837	15041-10002-40632	1212 S FLOWER ST	90015	14	126A207    34	5138026030	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM			PC Approved	09/09/2016 12:00:00 AM	ADDRESS	34.04113	-118.26555	CHANGES TO APPROVED SET(DELTA 4) TO METHANE DETECTION SYSTEM WITH 4 SUBTRANIAN LEVEL MIXED USED BUILDING. AN ADDITION OF 1 FA DEVICES & BATTERY CHANGES TO THE SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68838	18041-20001-41355	5400 W ADAMS BLVD	90016	10	123B177  1043	5043008022	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM			PC Approved	04/03/2019 12:00:00 AM	ADDRESS	34.03231	-118.36065	Revisions to approved plans.  Plan check for energy only.  (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant. Total lighting area = 1,538 sq. ft.Note: Building application has been generated under 18016-30000-25864)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68839	13041-20000-01388	18300 W ROSCOE BLVD	91325	12	192B125   682	2102001016	R4-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM			Reviewed by Supervisor	02/13/2013 12:00:00 AM	ADDRESS	34.22062	-118.53203	"Plan check for emergency generator. Northridge Hospital. Generator feeds ""F"" Tower."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68840	15041-10000-11052	19823 S HAMILTON AVE	90502	15	057B197   123	7351033***	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/14/2015 12:00:00 AM	04/14/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	33.85048	-118.28713	T24 ONLY, REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3256 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68841	18041-10001-22440	5932 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM			PC Approved	08/03/2018 12:00:00 AM	ADDRESS	33.94435	-118.38715	PLANCHECK FOR T24 ENERGY ONLY FOR EXISTING KIT BUILDING AREA WITHIN UNITED AREA CARGO BUILDING - TOTAL AFFECTED AREA = 7182 SF BUILDING PERMIT # 18016-10000-15264	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68842	10041-10000-12927	10901 W SHERMAN WAY area 5 & 6	91352	2	183B173    69	2410019036	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM			PC Approved	07/14/2010 12:00:00 AM	ADDRESS	34.20136	-118.36817	T24 and emergency lighting plan check for areas 5 and 6.  Existing permit.  Applicant indicates that no emergency lighting is required or installed for tenant space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68843	14041-10002-34485	850 W WASHINGTON BLVD	90007	1	124-5A203  64	5124020022	[Q]C2-2-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	PIN	34.0363201	-118.27708332	$0 submittal fee is due to Senate Bill SB-1222.Changes to approved set.  Delta-5 changes only.  Derating of main due to center-fed busbar configuration of existing service equipment.  (((PV2.  Install 23.1 kW DC utility-interactive, rooftop-mounted PV system.  3 Sunnyboy 6000TL Transformerless inverters. Changes on plans include: balanced three phase conection of inverters, PV wire per LAETL research reports, and update of inverter output calculations.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68844	15041-10000-16486	15207 W TYLER ST	91342	7	222B145   419	2604022034	R1-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.30156	-118.46416	PV1, INSTALL 13.407 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN PANEL.(41) MODULES: SUNPOWER SPR327NE-WHT-D(3) ABB PVI-3.8 AND PVI-3.8 AND PVI 4.2-OUTD -US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68845	12041-20000-17873	5800 W SUNSET BLVD	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			No Progress	07/31/2012 12:00:00 AM	ADDRESS	34.09728	-118.31693	T.I. at the 2nd and 3rd floor of existing office building #21.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68846	13041-10000-03721	1901 S BUNDY DR BLDG 1	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.03497	-118.45709	1901 S BUNDY DR BUILDING #1.  OUTDOOR LIGHTING AND INDOOR LIGHTING FOR HALLWAY AND RESTROOMS IN EXISTING SINGLE STORY OFFICE BUILDING.  ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68847	18041-10000-02468	940 N ALAMEDA ST	90744	15	033B213   754	7425043045	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.78313	-118.24383	REPLACE OUTDOOR  HID FIXTURES WITH NEW LED FIXTURES TITLE 24 ONLY. TOTAL AFFECTED AREA IS 39600 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68848	18041-20000-08717	7900 N BALBOA BLVD ' B '	91406	6	192B137   311	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.21347	-118.50092	PLANCHECK FOR POWER AND ENERGY.  NEW 27760 sf aircaraft hangar, building 'B':BUILDING PERMIT : 170102000001606	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68849	17041-10000-17651	1229 W 60TH ST	90044	9	105B197   324	6003012020	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	09/12/2017 12:00:00 AM	ADDRESS	33.98598	-118.29691	PV, INSTALLATIONOF A NEW 2.65 KW DC ROOF-MOUNTED SOLAR IN ON A DWELLING HOUSE.(10) MODULES: AXITPOWER AC-265P/156-60(1) INVERTER: FRONIOS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68850	19041-10000-25512	6101 W MANCHESTER AVE	90045	11	096B169   459	4107038022	[Q]C2-1VL-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM			PC Info Complete	07/30/2019 12:00:00 AM	ADDRESS	33.96004	-118.39177	CHANGE OF USE FROM RETAIL (STORAGE) TO OFFICE IN AN EXISTING COMMERCIAL AREA OF A GAS STATION BLDG IN A NON-CLASSIFIED AREA. T-24 ENERGY ONLY. AREA: 915 SQR FT.BUILDING PERMIT: 18016-10000-15516	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68851	14041-10001-26664	4401 W SUNSET BLVD	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM			PC Approved	03/17/2015 12:00:00 AM	ADDRESS	34.09708	-118.28526	REVISIONS TO PERMITTED SET OF PLANS REVISIONS LISTED ON ATTACHED SHEET))))))))Plan check for power and energy. Tenant improvement of existing church. 1 story. Area = 22344 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68852	16041-10000-09520	825 S HILL ST	90014	14	127-5A209 105	5144018021	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			04/13/2016 12:00:00 AM	07/05/2016 12:00:00 AM		Permit Closed	01/09/2019 12:00:00 AM	ADDRESS	34.04392	-118.25657	Temp Power for a  Proposed  49 story high rise with 490 APARTMENT Units. 1000amp Service with connected load including a fire pump, crane, man lifts and 3 transformers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68853	12041-10000-24834	1741 N IVAR AVE	90028	13	148-5A187  57	5546005019	C4-2D-SN	Central	Hollywood	Hollywood United		1902.00	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.10278	-118.32831	TI IN AN EXISTING OFFICE BLDG. EPC IS FOR T24. EMERGENCY LIGHTS ARE EXISTING. (FIRST & SECOND FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68854	17041-10000-22182	1035 N SWARTHMORE AVE 1-105	90272	11	129B125   835	4423016020	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	12/15/2017 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	Plan check for power and Title 24.  T.I. for 5 screen theater.  New 800 amp distribution board.  Performance method used for Title 24.  Area = 13,328 sq. ft.       Building permit #17016-10000-17932	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68855	10041-10000-00492	5600 W WILSHIRE BLVD	90036	4	132B181  1296	5089006***	(Q)C2-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			01/11/2010 12:00:00 AM	03/19/2010 12:00:00 AM		Permit Finaled	06/07/2010 12:00:00 AM	ADDRESS	34.06214	-118.35085	First time tenant for bank (Chase) in methane zone.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68856	15041-20001-26151	1919 S HARVARD BLVD	90018	10	126B193  1000	5074032011	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	34.03923	-118.30454	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (29) modules, and (29) power optimizers. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68857	18041-10000-46516	3096 S MCCLINTOCK AVE 1425	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/07/2018 12:00:00 AM	12/28/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.02647	-118.28575	PLAN CHECK FOR TITLE 24 ONLY FOR - CHANGE OF USE. CONVERSION OF STUDENT LOUNGE TO CREDIT UNION. INSTALLATION - TOTAL AFFECTED AREA = 960SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68858	15041-20000-36005	600 WORLD WAY Terminal 6-Space 645	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	11/09/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	"Install  ""Market 8600"" sign lighting inside Terminal 6 of LAX. PC for T-24 only. Total area: 19.26 sq. ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68859	11041-20000-25540	515 S FLOWER ST 45th floor	90015	9	126A205   222	5134009002	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			11/30/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Issued	11/30/2011 12:00:00 AM	PIN	34.03739243	-118.26899038	Modification to an existing fire alarm on the 45th floor.  Modification is the addition of 52 new devices and relocation of 26 existing devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68860	14041-10000-03107	725 N HARVARD BLVD	90029	13	141B193   456	5535030003	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.0843	-118.30409	PV1, Install 4.5 KW DC roof-mounted solar array on a 1-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U(18) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68861	15041-10000-21196	300 S SANTA FE AVE unit g	90013	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	FIRST TENANT IN COMMERCIAL SPACEFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68862	13041-20000-23803	22017 W BUENAVENTURA ST	91364	3	168B101   667	2170014006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.15533	-118.60652	PV1 TRANSFORMERLESS SYSTEM. 22 MODULES AND 1 INVERTER. 5.0 KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68863	15041-10007-10619	125 W 4TH ST	90013	14	129A211    44	5149020010	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	04/06/2020 12:00:00 AM	ADDRESS	34.0488	-118.24807	PC FOR CHANGES TO APPROVED SET  UNDER (DELTA  #1).SCOPE INCLUDES REMOVAL AND ADDITION OF DISTRIBUTION AND EQUIPMNET ON SLD. ALSO, REARRANGMENT OF LOADS IN THE DISTRIBUTION SYSTEM . ALL CHANGES ARE SHOWN ON THE PLAN WITH COMMENTS TO CLARIFY INDIVIDUAL CHANGES. THE OWNER WAS PRESENT TO CLARIFY AND APPROVE THE CHANGE OF ENGINEER <CONVERSION OF AN EXISTING 10 STORY OFFICE/BUILDING TO 188 LIVE/WORK UNITS, MIXED USED WITH RETAIL AND RESTAURANTS AT THE LOWER LEVEL. TWO SERVICES, PC FOR POWER AND ENERGY. BUILDING SUBMITTAL DATE BEFORE JULY 1, 2014 - 2008 ENERGY STANDARDS APPLIES. TOTAL SQ.FT 63,152FIRE VARIANCE ON FILE.>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68864	18041-20000-21378	21702 W HART ST	91303	3	183B105   679	2138005005	(Q)RAS4-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.19723	-118.60178	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68865	15041-10000-36102	2514 N DALY ST	90031	1	139-5A221 214	5204013003	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	34.07589	-118.21553	T-24, TI TO AN (E) COMMERCIAL, ART GALLERY, BUILDING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1745. ***INSPECTION FEES WERE PAID UNDER PERMIT NUMBER 15041-10000-18334.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68866	15041-10000-18879	2101 E PACIFIC COAST HWY FCCU BLDG	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Expired	03/05/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALL ONE HIGH RESISTANCE GROUNDING UNIT, TRANSFORMER SIZE AT 1288KVA.TR-168 @FCCU	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68867	16041-20001-30264	13908 W SUNSET BLVD	90272	11	129B133   347	4408011006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM			PC Approved	09/07/2016 12:00:00 AM	ADDRESS	34.04635	-118.50817	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 7.7 kWac and consists of (1) inverter and (22) modules. System interconnectes to a 400-amp rated MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68868	15041-10000-16464	16134 W RUNNYMEDE ST	91406	6	186B141   425	2205024018	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.2056	-118.48483	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED LIGHT FIXTURES. TOTAL AREA 7998 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68869	12041-10000-19662	10510 N VASSAR AVE	91311	12	207B101   231	2722033039	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2012 12:00:00 AM	09/25/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.26113	-118.60522	Plan check for new 6.48KW roof mounted photovoltaic system (Aurora transformerless inverter). Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68870	15041-20000-23152	10200 N SALOMA AVE	91345	7	204B149   300	2647003025	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.25552	-118.45742	Installation of new roof mounted solar PV array.  Total system size = 3.87 kWac.  Micro-inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68871	16041-10000-38344	676 S MOULTON AVE	90031	1	135A221    38	5410016006	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM			PC Approved	10/28/2016 12:00:00 AM	ADDRESS	34.06382	-118.2197	Plan check for Title 24 only in existing space wearhouse load less than 400A. Total area out door and indoor: 21,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68872	18041-10000-16843	12280 W MONTAGUE ST	91331	7	204B165   203	2537018022	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.25522	-118.40059	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68873	09041-70001-20590	3923 W JEFFERSON BLVD	90016	10	120B185   823	5050028057	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM	03/12/2010 12:00:00 AM		Permit Finaled	03/18/2010 12:00:00 AM	ADDRESS	34.0257	-118.33904	SUPPLEMENTAL PERMIT FOR (9) 20AMP CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68874	15041-10000-17925	1000 W WILSHIRE BLVD STE 660	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	Energy plan check for  partial offices remodel T.I located in the 6th floor of a high rise building. Scope is design-build, work includes new lighting and receptacles; all panels are exsiting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68875	16041-10000-45647	6007 W SUNSET BLVD	90028	13	147A191    65	5545007027	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			Reviewed by Supervisor	02/08/2017 12:00:00 AM	ADDRESS	34.0982	-118.31997	PC FOR POWER AND ENERGY. NEW 7 STORY, 63 UNIT APT BUILDING; 4 STORIES OF RESIDENTIAL UNIT,  2 STORY PARKING GARAGE AND FIRST FLOOR FOR COMMERCIAL SPACE, 1600A SERVICETOTAL AREA 74460SQ FT.B# 16010-100000-06129	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68876	16041-20000-18001	6860 N MCLAREN AVE	91307	12	183B097   693	2026022003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.19549	-118.62432	PV1.  Install 12.22 kW DC roof mounted PV system.  (47) 260W modules with 11.4 kW transformerless central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68877	18041-10000-45124	5501 S WESTERN AVE BLDG 2	90062	8	108B193   691	5005031026	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	11/15/2020 12:00:00 AM	ADDRESS	33.99225	-118.30913	CHANGE OF USE TO CONVERT EXISTING 17 GUESTROOM MOTEL TO INTERIM TEMP  HOUSING.INSTALL 1 NEW 400 AMP SERVICES FOR BLDG-2, PANELS & CIRCUITS. PLAN CHECK FOR POWER & ENERGY. BULDING PERMIT: 18014-10000-05631PLAN CHECK FEES ARE PAID UNDER THIS PERMIT. ANOTHER PERMIT AND FEES ARE GENERATED FOR BLDG 1 #19041-10000-250152-2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68878	18041-20000-04334	8353 W GRAND VIEW DR	90046	4	148-5A175  22	5556019020	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.10318	-118.37269	pv1install roofmounted pv system sized 7.6 with battery back up interconnected wiuth msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68879	12041-20000-03915	2500 N JUPITER DR	90046	4	153B177   536	5569015066	RE11-1	Central, South Valley	Hollywood	Hollywood Hills West	YES	1941.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.11595	-118.36326	PV System on roof of  SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68880	18041-20000-14066	3303 W WILSHIRE BLVD 4th Floor-Rest Room	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/17/2018 12:00:00 AM			PC Approved	04/17/2018 12:00:00 AM	ADDRESS	34.06195	-118.29439	Plan check for Title 24 only in existing restroom on 4th Floor , new lighting T.I. Total area: 445 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68881	17041-10000-07539	9124 N RESEDA BLVD	91324	12	198B125   246	2764013018	(Q)C2-1VL	North Valley	Northridge	Northridge East		1152.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.23611	-118.53588	PC FOR ENERGY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL ARAE 126725 SQ FT. /OUTDOOR/	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68882	19041-10000-09986	1130 S RIDGELEY DR	90019	4	132B177  1180	5085008012	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.05487	-118.35328	Plan check for (2) battery power supplies and new equipment added to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68883	15041-20000-17087	15477 W VENTURA BLVD	91403	5	168B145   725	2261039008	C4-1L, R3-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/24/2017 12:00:00 AM	ADDRESS	34.15484	-118.47126	Plan check for power and lighting. Primary use is medical office with exam rooms.*****Building Permit Work Description: 15016-10000-06367*****TENANT IMPROVEMENTS: LOWER LEVEL FLOOR, NEW DENTAL CLINIC AND EXISTING OFFICES; THIRD FLOOR PLAN: CONVERT PORTION OF EXISTING OFFICES TO BE NEW EXAM ROOMS.[1] FIRST FLOOR AND PORTION OF 3RD FLOOR ARE PLAN CHECK FOR OSHPD 3. PLEASE SEE PLAN MAINTENANCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68884	14041-10001-06739	1354 S HAUSER BLVD	90019	10	129B177   766	5085032016	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.04969	-118.35621	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE5000A-US-ZB-U(22) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68885	12041-20000-08385	13625 W VENTURA BLVD	91423	4	165B157   627	2360006028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.14804	-118.43036	TI for existing office space. 2nd story. Low-rise commercial building. Plan check for Energy and emergency lighting. 748 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68886	17041-20001-34489	15926 W HAMLIN ST	91406	6	180B141   834	2233014016	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM			PC Approved	10/06/2017 12:00:00 AM	ADDRESS	34.1876	-118.48031	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.5kW ungrounded pv system. (16) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68887	10041-10000-14710	1436 S BUTLER AVE Bldg 7	90025	11	129B149   200	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Corrections Issued	09/24/2010 12:00:00 AM	ADDRESS	34.04758	-118.45352	NEW SERVICE , PANELBOARDS AND CIRCUITS FOR 15 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68888	16041-20000-37242	10644 W TUXFORD ST	91352	7	195B177     7	2544028009	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.23575	-118.36315	Plan check for a PV1 roof-mounted PV system. System size is 9.8 kWac and consists of (30) AC modules and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68889	15041-20000-20017	3415 S SEPULVEDA BLVD	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.02055	-118.42347	Title 24 plan check only.  Lighting retrofit to basement, 1st floor, and 2nd floor of existing parking garage.  Total area = 104,963 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68890	18041-10001-07233	200 E BAUCHET ST	90012	14	133-5A215 236	5409015017	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	02/19/2021 12:00:00 AM	ADDRESS	34.05873	-118.23498	CHANGE TO AN APPROVED SET , CHANGE IS UNDER DELTA-17 AND RED HAND MARK UP. CHANGE ASSOCIATED WITH LADWP SUBSTATION REDESIGN AND REMODEL OF PARKING GARAGE.ORIGINAL SCOPE: FULL PLAN CHECK OF A NEW 4-STORY DATA CENTER BUILDING (LA3).  (4) New services at 600A 34.5 k; (4) 34.5kV/12.47kV xfrmr, (3) medium voltage dist. boards; (6) medium voltage unit substations; other equipment are 600V or less.   18010-10000-00872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68891	16041-20000-20547	19108 W SCHOENBORN ST	91324	12	192B121   676	2784018012	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	08/05/2016 12:00:00 AM	ADDRESS	34.2218	-118.54952	Plan check for PV roof mounted system. System size: 6.0kW with 26 modules an 1 inverter(6.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68892	19041-10000-35313	301 S WESTERN AVE #205	90020	10	135B193   272	5503002003	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2117.03	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.06877	-118.30952	Energy plan check for a commercial T.I. Scope includes new lighting and equipment with a total lighting area of  701-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68893	13041-20000-08829	2034 S COTNER AVE	90025	5	126B153   603	4323024032	M2-1	West Los Angeles	West Los Angeles	Westside		2677.00	Electrical	Electrical	Commercial			04/05/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.04138	-118.44096	solar commercial	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68894	19041-10000-27510	6950 N TUJUNGA AVE	91605	2	183B173   168	2319005002	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Issued	07/18/2019 12:00:00 AM	ADDRESS	34.19678	-118.37888	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68895	16041-20001-41157	11100 N SCOVILLE AVE	91040	7	210B189    61	2551019006	RA-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	PIN	34.2710718	-118.31390494	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 60A subpanel fed from a 400A split bus panel.  10kW ungrounded system. (30) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68896	17041-20001-09618	7724 N VICKY AVE	91304	12	189B097  1090	2013018023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.21079	-118.61933	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with 225A MSP.12.8kW ungrounded system. (40) 320W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68897	16041-20000-29903	21860 W BURBANK BLVD SUITE 175	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.17198	-118.60379	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR  LAW OFFICES OF BORSKY AND ZELINSKY.  2409 SQFT. SUITE 175	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68898	12041-10000-18972	303 S UNION AVE	90017	1	133-5A205 120	5153003036	C2-1	Central	Westlake	Westlake North		2089.04, 2091.01	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.06077	-118.26819	Plan check power and energy for new lighting, loads, equipment for medical office located on 2nd floor. Per applicant building is/will not be state licensed.  Not checked for OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68899	13041-20000-14790	13281 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 3.2 KW. USING 15 MODULES ENPHASE MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68900	18041-10000-42945	1149 S HILL ST 340	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.03926	-118.26099	Plan check for T24 only, TI on the 3rd floor (E) office. New circuits are fed from existing panelboards. Total area: 2,220 sq.ft((B# 18016-10000-34194))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68901	15041-10000-02768	5422 N KINCHELOE DR	90041	14	165A227    26	5669009033	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2015 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	03/24/2015 12:00:00 AM	ADDRESS	34.14663	-118.19989	Plan check for a PV1 roof-mounted PV system. System size is 5.3 kWac. System consists of (21) modules and (21) micro-inverters. Standard plan is NOT being used. Approved for over-the-counter by F.Y.NOTE: Plan check was done in person as the online permitting system was not letting the contractor pull the permit for a micro-inverter system above 3 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68902	18041-20000-32579	4838 N LAUREL CANYON BLVD	91607	2	168B165   363	2355010021	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			PC Approved	08/27/2018 12:00:00 AM	ADDRESS	34.15879	-118.39629	ti to an existing medical office.  addition of plugs thru out and lighting to (2) renovated bathrooms only.  plan check for power and energy.permit fees covered under application number 18041-90000-31589.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68903	12041-10001-08632	4775 S BROADWAY	90037	9	111A203   100	5110015013	C2-1VL	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Expired	05/21/2014 12:00:00 AM	ADDRESS	33.99939	-118.27853	New fire alarm panel with new devices on the 1st floor and replacement of devices on the 2nd and 3rd floors.(((    change of mfg for panel and change of part number.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68904	13041-20000-35097	4500 W LOS FELIZ BLVD	90027	4	150B197    26	5590003039	[Q]C4-1	Central	Hollywood	Greater Griffith Park		1891.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.11156	-118.28786	T24 FOR CHANGE OF USE TO RESTAURANT. Plan check only. permit under 13041-10000-31077 -mt 3/5/2014.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68905	17041-20000-06455	21700 W OXNARD ST ste 1600	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Info Complete	02/28/2017 12:00:00 AM	ADDRESS	34.17901	-118.60179	ti to an existing commercial building (highrise) adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 8033.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68906	14041-10000-07329	1606 S FLOWER ST	90015	14	124-5A205  56	5134008006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/19/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.03666	-118.26879	TI. NEW LIGHTING FOR A STORAGE. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68907	16041-10000-01119	10888 W VINEDALE ST	91352	6	195B173   568	2408010027	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.22763	-118.36785	PV1, rooftop solar installation, interconnects with 200 MSA(16) modules, (1) PVI-3.6-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68908	18041-10000-16907	20306 W VIA CELLINI	91326	12	219B113    83	2701045030	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	05/29/2018 12:00:00 AM	ADDRESS	34.29323	-118.57668	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (15) MODULES AND (15) OPTIMIZERS, AND (1) INVERTER. TOTAL SYSTEM SIZE 5KWAC AND 4.65KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68909	17041-20001-12638	4690 W COLORADO BLVD	90039	13	162B201    75	5593018013	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Approved	10/10/2017 12:00:00 AM	ADDRESS	34.14012	-118.27542	"[[10/10/17 CHANGES TO APPROVED SET. DELTA 4 CHANGES ONLY. PLANCHECK ONLY. UPDATING PLAN VIEW TO MATCH THE CONDUCTOR DETAILS ON SINGLE LINE DIAGRAM]]]]4/18/2017Changes to an approved set of plans.  changes noted delta 3. changes reflect (4) new motor loads connected to MCC ""CHILLER"".  Plan check for power only.(((Changes to approved set.  Addition of new 7.5 kVA power center.  Updated single line diagram and floor plan.REF HVAC APP 16044-20000-11351)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68910	15041-10001-24052	1500 W PACIFIC COAST HWY Bldg A	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION OF 76 DEVICES AND 2 POWER SUPPLIES, FOR FUTURE ADA REQUIREMENT.  (((NEW FIRE ALARM SYSTEM WITH 77 DEVICES FOR A New 3-story, 28 unit apartment with garage, Typev VA construction. CONTRIOL PANEL IS ON RE RM APPLICATION # 15041-10000-24054.)))-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68911	15041-20000-02381	9818 N RHEA AVE	91324	12	201B121   203	2763027024	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.24913	-118.54135	PV1Using standard plan.Install roof-mounted solar array on SFD. Interconnect with 200A MSP.System size: 5kW. Ungrounded system.23  255W modules across 3 strings (7 and 8+8=being combined)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68912	16041-10001-40522	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM			PC Approved	01/04/2017 12:00:00 AM	ADDRESS	34.21302	-118.45859	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING ROOF-TOP. TOTAL SYSTEM SIZE IS 553.28KWdc / 390.0KWac.(1729)MODULES-JA JAP6 72-320/3BB(13)INVERTERS-SMA 30000TL-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68913	17041-10000-35622	10853 N AQUEDUCT AVE	91344	12	207B141    76	2662021017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.26798	-118.47408	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(26)MODULES-SUNSPARK SST-300W(26)OPTIMIZERS-SOLAREDGE OPTIMIZERS P320(1)INVERTER-SOLAREDGE SE7600H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68914	13041-20001-00691	4170 S DEL REY AVE	90292	11	105B153    13	4230005033	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			04/11/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	33.98745	-118.44398	Changes to approved set of plans. Relocation of luminaires, no changes to lighting power.Plan check for energy. Outdoor parking lot. 58213 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68915	15041-10000-10327	7842 N BURNET AVE	91405	6	189B145   484	2209036014	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.21324	-118.46279	Ti to an existing single story commercial building, newly connected load <400amp. PC for energy and emergency lighting only. Total Sq.Ft. 4430.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68916	10041-20000-19030	9931 N GLENOAKS BLVD	91352	6	201B169    41	2537026013	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Issued	12/21/2010 12:00:00 AM	ADDRESS	34.25034	-118.38841	1600A Service upgrade to existing building.  Plan check for power only.  All loads are existing to remain. No new load added.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68917	12041-10000-16667	13439 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15778	-118.42614	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #15	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68918	12041-10000-05712	11640 W SAN VICENTE BLVD STE 106	90049	11	129B145    21	4265005022	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	05/23/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	ADDRESS	34.05369	-118.46307	FULL PLAN CHECK ENERGY AND POWER.  FIRE ALARM WILL BE ON A SEPARATE APPLICATION.CHANGE OF USE FROM RETAIL TO HEALTH CLUB; INTERIOR RENOVATION OF AN EXISTING SUITE; NO ADDITIONAL SQUARE FOOTAGE ADDED TO EXISTING BUILDING OR SUITE; DEMOLITION OF INTERIOR NON STRUCTURAL PARTITIONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68919	11041-10000-13116	12121 W WILSHIRE BLVD #   322	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	06/29/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	PIN	34.04391963	-118.46825257	Title 24 and emergency lighting, for 12 story building suite 322.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68920	16041-20001-08865	6324 W 85TH PL 1-24	90045	11	096B165   468	4108019019	[Q]R3-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	33.96032	-118.39734	Expedited RSES plan check per applicant request.  PV2.  Install 13.6 kW roof-mounted PV system.  (2) 6000W inverters with (44) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68921	13041-10000-32640	3650 W MARTIN LUTHER KING, JR BLVD SPACE #232	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.01118	-118.33649	T.I. to existing beauty salon.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68922	13041-20000-11907	7520 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			PC Approved	05/08/2013 12:00:00 AM	ADDRESS	34.20692	-118.4942	energy plan check existing permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68923	18041-10000-18835	1232 W 61ST ST	90044	9	105B197   778	6003025007	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	33.98404	-118.29697	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOAL SYSTEM SIZE IS 5.60KWdc / 6.00KWac  (16)MODULES-HYUNDAI HiS-S350TI(16)OPTIMIZERS-SOLAREDGE P370(1)INVERTER-SOLAREDGE SE6000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68924	14041-20000-21779	11121 W PENDLETON ST	91352	6	198B173    45	2538011010	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	10/06/2014 12:00:00 AM	ADDRESS	34.23852	-118.37336	Plan check for installing conduit and wire to supply power to new motors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68925	15041-20001-22837	325 W ADAMS BLVD	90007	9	121-5A205 132	5126018032	(T)(Q)C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.02712	-118.27319	Changes to approved set.  Changing lights from 35 W LEDs to 11 W LED.  Regular toggle switches to be used instead of dimmer switches.     Plan check for 1st time tenant in mixed used building. Total indoor area: 4470sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68926	18041-10000-17365	11263 N BALBOA BLVD	91344	12	210B133   116	2697021013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.2754	-118.50241	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
68927	12041-20000-29785	9711 N WHEATLAND AVE	91040	2	201B177   348	2544008014	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.2458	-118.35761	New 17.42kw rooftop photovoltaic system for an existing single family home.  Plan check only for PV System, not for service upgrade or derating main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68928	16041-10002-06786	15838 W BAHAMA ST	91343	12	195B141   286	2672007006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM			Corrections Issued	10/03/2016 12:00:00 AM	ADDRESS	34.23272	-118.47775	Changes to approved set noted under delta-3. Note: Fees $0 due to SB 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68929	17041-10001-31307	8440 N BALBOA BLVD #101	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	Delta 2 revisions to permitted set of plans. Plans were revised to show changesmade  during constructions and to represent as-built conditions((((((((FIRST TENANT -PIZZAPRESS- IN NEW COMMERCIAL BUILDINGFULL PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68930	10041-20000-09546	19336 W NORDHOFF PL Total Wine	91324	12	195B117    25	2783028013	C4-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	06/28/2010 12:00:00 AM		Permit Finaled	09/28/2010 12:00:00 AM	PIN	34.23366051	-118.55450852	Re-Plan check power and energy for first time tenant. Total Wine & More retail store. Original electrical plans were lost #08041-20000-09637. Building permit #08016-20000-07063	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68931	19041-20000-46596	7901 W MCGROARTY ST	91040	7	204B193  1315	2559025009	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.2524	-118.30503	PV1.  Installation of 9.24 kW DC roof mounted grid tied PV system.  (28) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68932	16041-20000-22205	7900 N ALABAMA AVE	91304	3	189B105   315	2110005017	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	05/10/2018 12:00:00 AM	ADDRESS	34.21402	-118.59927	PLANCHECK FOR T24 ENERGY. RESTROOMS IN EXISTING WAREHOUSE. 265	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68933	17041-10000-25414	139 N WESTERN AVE	90004	4	138B193   935	5517003019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2115.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Closed	03/07/2018 12:00:00 AM	ADDRESS	34.0741	-118.3095	RESTAURANT TI TO FIRST AND SECOND FLOOR PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68934	13041-10000-07645	621 S WESTERN AVE	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			03/26/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.0628	-118.30928	PC FOR ENERGY. TI existing general STORE. less than 400 A per applicant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68935	10041-10000-08576	11707 W SAN VICENTE BLVD	90049	11	132B145   531	4401018017	C1.5-1VL	West Los Angeles				2641.01	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	10/04/2010 12:00:00 AM	ADDRESS	34.05377	-118.46609	REMODELING THE INTERIOR OF AN EXISTING  STARBUCKS COFFEE SHOPPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68936	15041-30000-39709	8438 N DELCO AVE	91306	3	192B109   406	2781024012	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.22308	-118.57833	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68937	14041-20000-04767	2250 E ALCAZAR ST	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/20/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.06307	-118.2	EMERGENCY SYSTEM MODS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68938	10041-20000-15407	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM			PC Info Complete	08/06/2010 12:00:00 AM	ADDRESS	34.20103	-118.38536	Per customer request. Plan check for Non-Life safety UPS equipment change out. No increase in load. KPNS UPS Replacement Project.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68939	19041-10000-26275	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Issued	10/31/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	T-24 PLAN CHECK FOR AN INTERIOR TENANT IMPROVEMENT FOR UNION BANK BRANCH ON THE FIRST FLOOR OF AN (E) HIGH RISE BUILDING.  SCOPE OF WORK INCLUDES NEW 75KVA TRANSFORMER, EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 3399SQ.FTB#19016-10000-18015	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68940	15041-10000-31882	6181 N SEPULVEDA BLVD	91411	6	177B145   356	2242001014	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.1828	-118.46646	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL.  NEWLY CONNECTED LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FIITAGE 1767	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68941	14041-20001-21470	11530 N MCLENNAN AVE	91344	12	213B133   562	2610006025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM			PC Approved	08/19/2014 12:00:00 AM	ADDRESS	34.28038	-118.50089	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect w/MSP. System size: 11kW(1) SolarEdge S6000A-US-ZB-U transformerless inverter(1) SolarEdge S5000A-US-ZB-U transformerless inverter(51) Trina Solar #TSM-255PA05.18 pv modules(51) SolarEdge P300 power optimizers]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68942	15041-10001-26271	22200 W SHERMAN WAY	91303	3	183B101   106	2024013189	C1-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.20073	-118.61062	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA B ON PLANS. ADDITION OF STORM WATER IRRIGATION PUMP AND CONTROLLER. UPDATED LOAD CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68943	16041-20000-38213	17755 W ALONZO PL	91316	5	165B129    33	2182025011	RA-1	South Valley	Encino - Tarzana	Encino	Yes	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.15233	-118.52	Plan check for a PV1 roof-mounted PV system. System intercontects with a 400-amp MSP and size is 10 kWac. System consists of (1) inverter and (44) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68944	12041-10000-28086	2000 S AVENUE OF THE STARS Suite #815-N	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/21/2012 12:00:00 AM			PC Info Complete	11/21/2012 12:00:00 AM	ADDRESS	34.05868	-118.41546	TI IN AN EXISTING OFFICE BUILDING IN SUITE 815N ON THE 8TH FLOOR. PLAN CHECK FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68945	14041-10001-23953	16600 W ADLON ROAD	91436	5	165B137   518	2291013046	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.14506	-118.49537	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{INSTALL 16.83 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(66) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGED SE6000A-US-ZB-U}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68946	11041-10000-19434	932 S PARK VIEW ST	90006	1	130-5A201  13	5136004011	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			09/13/2011 12:00:00 AM	11/14/2011 12:00:00 AM		Permit Finaled	04/26/2012 12:00:00 AM	ADDRESS	34.05389	-118.28242	CHANGE OF USE FIRST FLOOR OF (E) 2-STORY SINGLE FAMILY DWELLING (R3 OCCUPANCY, 1122 SQFT) TO CHILDREN DAY CARE CENTER (E  OCCUPANCY); 2ND FLOOR REMAIN AS SFD.  <<<Bldg Permit: 10016-10000-15646>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68947	18041-20000-35439	8907 S DE HAVILAND AVE	90045	11	096B169  1014	4123008003	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	09/17/2018 12:00:00 AM		Permit Expired	03/05/2024 12:00:00 AM	ADDRESS	33.95615	-118.39157	PV1.  Install 5.2 kW DC roof mounted grid tied PV system with energy storage system.  (18) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68948	11041-10000-00096	440 S VERMONT AVE # 201	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			01/04/2011 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Expired	11/17/2022 12:00:00 AM	ADDRESS	34.0659	-118.29143	FIRST TENANT -  RESTURANT (B OCC.)(467 S.F.);	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68949	16041-30000-16369	710 N EL CENTRO AVE	90038	13	141B189  1235		(T)(Q)RAS3-1	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.08386	-118.3243	Plan check for power and energy. Project site is an existing mixed-use commercial building. Project scope is a tenant improvement/change of use of retail to restaurant to a portion of the 1st floor. Total lighting area = 3,500 sq. ft. A2 occupancy.Note: Building application has been created under 16016-30000-02042	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68950	14041-20000-03733	187 N HIGHLAND AVE	90036	5	138B185   116	5513007031	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.07587	-118.33877	Additional to existing single family dwelling.  Add 100A subpanel to existing 200A service, and rewiring.  Per Inspector Request, plan check is required.  Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68951	15041-10001-10892	3303 N NORTH BROADWAY	90031	1	138A225    15	5208012006	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.07394	-118.20626	"Delta ""6"" changes to approved plans with new circuits and equipment. Floor plan also being modified.<<<Plan check for power and energy for New 3 story commercial building 480/277V, 1600 AMP Service Core & Shell only.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68952	17041-20000-37075	11730 W VENTURA BLVD	91604	2	162B169   363	2369027004	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.14158	-118.38881	Change of use from office to  vet clinic.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68953	15041-10000-15637	8715 S CROCKER ST	90003	9	096A205    45	6041017005	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	33.95863	-118.26822	Retrofit of existing lights to LED fixtures.  Title 24 Part 6 plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68954	18041-20000-47958	12403 W ALBERS ST	91607	2	174B165   867	2347002011	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.17045	-118.40332	PV1.  Install 12.87 kW DC roof mounted grid tied PV system.  (39) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68955	15041-20002-20845	6501 W OLYMPIC PL	90035	5	132B173   458	5087007009	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.05819	-118.37215	7.29.2015 - Plan check for changes to approved set: add AC disconnect near front of house, and DWP solar production meter near MSP. Show their locations on site plan and single line diagram only.  [Plan check for PV roof mounted system. System size: 6.0kW with 24 modules and 1 inveter(6.0kW)]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68956	12041-10001-11802	14250 W VALLEY VISTA BLVD	91423	4	162B153  1052	2274018004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2012 12:00:00 AM			PC Approved	07/24/2012 12:00:00 AM	ADDRESS	34.1447	-118.44409	Modification to previously approved set of drawings to change inverter type.  Plan check only.  Permit is on main application.             <<<<Plan check new roof mounted 9.6KW roof mounted photovoltaic system for single family dwelling.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68957	16041-10001-02007	17200 S VERMONT AVE	90247	15	066B197   278	6121015***	M1-1VL	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	33.87528	-118.29083	ADDED BOOSTER PUMPS AND REVISED WIRE SIZING. PC FOR CHANGES NOTED DELTA 7 AND 8 REVISIONS. PLAN CHECK AND PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68958	16041-20000-26775	327 S HOOVER ST 1-48	90020	13	136-5A201 207	5501022007	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.06799	-118.2845	"'0$ permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 40kW with 176 modules and 4 inverters(10.0kW) connected to MSP"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68959	19041-10000-13573	1 E WASHINGTON BLVD	90292	11	103-5A145  26	4226023006	C1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Issued	05/02/2019 12:00:00 AM	ADDRESS	33.97931	-118.46683	INTERIOR TENANT IMPROVEMENT TO EXISTING RESTAURANT-new 200A service, panelboards,new branch circuits, and reconnect existing branch circuits.plan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68960	16041-20000-31372	21600 W OXNARD ST Suite 720-730	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 only. Project site is existing suites within a commercial building. Project scope is a tenant improvement. Total lighting area = 2,534 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68961	19041-20001-00592	5049 N GLORIA AVE	91436	5	171B141   528	2261017011	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.16112	-118.47947	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED DELTA A CHANGES ONLY. RELOCATION OF SERVICE EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68962	12041-20000-15000	340 S LA BREA AVE	90036	4	135B181   300	5507008018	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM			PC Info Complete	07/19/2012 12:00:00 AM	ADDRESS	34.06768	-118.34383	Install general/emergency lighting.  Plan check for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68963	15041-20001-22789	600 WORLD WAY Space 634	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM			PC Approved	02/16/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	Changes made to approved plans - change of lighting fixtures and panel size.  (((Title 24 plan check only.  Total area = 1,310 sq. ft.  T.I. to existing commercial space.  New 400 A panel to provide power.  Upgrading 845 sq. ft. walk in cooler as well.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68964	10041-20000-11125	6100 W MELROSE AVE	90004	4	141B185   595	5523001017	C2-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			06/11/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	PIN	34.08320613	-118.33343965	Plan check T-24 Energy for general lighting for office/warehouse TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68965	15041-20001-42582	8525 N HAYVENHURST AVE	91343	12	192B137   110	2689014003	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM			PC Approved	12/21/2015 12:00:00 AM	ADDRESS	34.22574	-118.49406	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (45) modules, (2) combiner boxes, and (1) load center. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68966	14041-20000-04036	4038 N STONE CANYON AVE	91403	4	163-5A147  32	2277023010	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.14411	-118.46074	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH MAIN SERVICE. TRANSFORMER SYSTEM, SIZED @ 7.28 KW DC. (1) INVERTER 6kW WITH REQUIRED AFCI PROTECTION, (28) REC 260W MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68967	14041-10000-10508	624 W ISABEL ST	90065	1	144A221    75	5453018014	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1853.10	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.09042	-118.22052	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, INTERCONNECT TO THE MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(14) MODULES: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
68968	13041-10001-24742	2506 1/2 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.0335	-118.2974	EXPEDITED PER APPLICANTS REQUESTPV1. INSTALL 2.94 KW DC ROOF MOUNTED SOLAR ARRAY OF 12 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68969	18041-10000-13524	8017 W 3RD ST	90048	5	138B177   737	5511023036	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.07201	-118.364	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68970	17041-10000-03795	1843 N WOLLAM ST	90065	1	150A219   268	5464023016	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.10412	-118.22562	PC FOR ROOF MOUNTED SOLAR FOR SFD. SYSTEM SIZE IS 1.5KW AC6 MODULES CANADIANSOLAR -340M6 MICRO INVERTERS ENPHASE -M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68971	15041-10000-19497	650 S WESTERN AVE	90010	10	132B193   148	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.06143	-118.30892	CHANGE OF USE FROM (E) RETAIL TO WABA  RESTAURANTPLAN CHK IS FOR TITLE 24-OCCUPANT LOAD IS 86	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68972	15041-10005-14620	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	Changes to approved set of plans. Changes include alteration/ addition of circuits and notation all noted under delta 40.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68973	16041-10000-16707	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	07/29/2016 12:00:00 AM		Permit Finaled	01/30/2024 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC FOR NEW MEDIUM VOLTAGE DISTRIBUTION. CUSTOMER OWN SUBSTATION 34.5KV TO FEED NEW 34.5KV DISTRIBUTION BOARD. NEW BOARD INSTALL TO REPLACE A COUPLE OF EXISTING EQUIPMENT. NEW BOARD TO REFEED EXISTING SUBSTATIONS. ALSO INSTALL NEW POWER TO OPERATE AUX EQUIPMENT IN 34.5KV BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68974	17041-10000-33821	14910 W VENTURA BLVD	91403	4	166-5A149  30	2276004004	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Issued	09/21/2017 12:00:00 AM	ADDRESS	34.15226	-118.45783	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68975	17041-10000-26000	1027 W MANCHESTER AVE	90044	8	097-5A199 230	6033026021	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Closed	01/26/2024 12:00:00 AM	ADDRESS	33.96019	-118.29276	PC FOR ATM MACHINE LIGHTING OUTDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68976	10041-10001-09968	11480 W TIARA ST	91601	2	177B169   978	2338012900	PF-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Commercial			01/18/2011 12:00:00 AM			PC Info Complete	01/18/2011 12:00:00 AM	ADDRESS	34.17839	-118.38171	DELTA 4 CHANGES TO THE APPROVED PLANS.  NEW ONE STORY MULTIPURPOSE BUILDING WITH A MULTIPURPOSE ROOM, AN OFFICE AND ANCILLARY SPACES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68977	12041-20000-17759	5750 W WILSHIRE BLVD	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/30/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	34.06227	-118.3542	T.I. to high rise building on the 2nd floor of Digital Operation Room.  Install general/emergency.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68978	16041-20000-04381	3457 E GARNET ST	90023	14	120A225   209	5190001026	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.02246	-118.20207	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (14) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68979	14041-20001-29240	12946 W HESBY ST	91423	4	171B161   914	2358028008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	34.16214	-118.41579	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. NON STANDARD PLAN. SYSTEM SIZE: 7KW DC.(21) SUNPOWER SPR MODULES(1) SUNNYBOY6000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68980	14041-10000-08586	5047 N EAGLE ROCK BLVD	90041	14	162A221   160	5686002011	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/08/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.13832	-118.21463	FULL PLANC CHECK FOR A RESTURANT , TI ASSEMBLY POSITIION. TOTAL AREA 1800 SQ FT.PLAN CHECKER PLEASE VERIFY THE # OF DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68981	19041-20000-42061	7117 N LAUREL CANYON BLVD	91605	2	183B165   108	2321001010	M1-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Issued	11/19/2019 12:00:00 AM	ADDRESS	34.1998	-118.39673	Power and lighting for (E) building using (E) service and distribution.Building permit under 19016-20000-19663.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68982	17041-20000-11973	2012 S BUNDY DR	90025	11	123B149   367	4259020021	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.03371	-118.45499	"PLANCHECK FOR T24 ENERGY. TENANAT IMPROVEMENT FOR LAMPS PLUS. 3000 SQFT.""COMPLY WITH DEPARTMENT ORDER effective date12/30/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".building permit # 16016 20000 30227"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68983	17041-30000-31277	201 WORLD WAY	90045	11	090B165    76	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	33.94469	-118.40336	Plan check for power and energy T.I. in existing space LAX. Talor Method is being use. Total area: 7,500 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68984	17041-10001-03579	300 S GRAND AVE LP160	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	PIN	34.05243427	-118.25124731	Changes to approved set.  New lighting layout including track lighting.  Relocate subpanels.  All changes clouded	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68985	14041-20001-11253	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM			PC Approved	09/27/2014 12:00:00 AM	ADDRESS	34.0344	-118.45642	SUPPLEMENTAL TO REMOVE AND REPLACE LIGHTING FIXTURES.((TI in (E) commercial office space in single story building.  Power and energy.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68986	19041-10000-23918	18362 W OXNARD ST BLD. 4	91356	3	177B125   753	2157002134	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Closed	04/26/2022 12:00:00 AM	ADDRESS	34.17985	-118.53311	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW 600A SERVICE 120/208V WITH ASSOCIATED EQUIPMENT - TOTAL NEW CONNECTED LOAD OF APPROX. 400A. TOTAL AFFECTED AREA 307 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68987	12041-10001-06949	16830 W VENTURA BLVD	91436	5	168B133   167	2289001034	(Q)C4-1L, (Q)PB-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM			PC Approved	11/27/2012 12:00:00 AM	ADDRESS	34.15886	-118.50032	Plan check only, permit is existing under 12041-20000-06949.  Plan check only for delta 5 and delta 4.1 load and title 24 still within the requirement of the code.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68988	14041-10000-26166	938 S ORANGE GROVE AVE	90036	4	132B177   563	5086012008	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			09/23/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	09/03/2016 12:00:00 AM	ADDRESS	34.05864	-118.36241	New 15 units  4 story apartment building. 1200 amp service. Methane zone. Building permit#: 13010-10000-03007	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68989	19041-10000-50498	13438 N NORRIS AVE	91342	7	225B145   102	2501024005	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.31614	-118.47131	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEMSIZE IS 10KWac/12.8KWdc. SCOPE OF WORK IS 40 MODULES (HANWHA Q-CELL 320) WITH OPTIMZERS (SEP320), LEADING TO A CENTRAL INVERTER (SE10000H-US), NOTE MAIN BREAKER HAS BEEN DERATED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68990	12041-20000-21016	176 S ALVARADO ST	90057	13	135A205   145	5154007002	C2-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	ADDRESS	34.06452	-118.27148	T24 ONLY FOR MEDICAL CENTER AS REQUESTED BY INSPECTOR GUNSUL. 1727 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68991	18041-10000-10613	1615 E 22ND ST	90011	9	118-5A213 247	5118024019	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.01737	-118.24497	Plan check for Title 24 only remove HID fixtures and replace with new LED fixtures outdoor lighting. Total area: 7,450 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68992	11041-10000-05691	1300 E FACTORY PL Building-K	90013	14	126A215   235	5164008031	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			03/23/2011 12:00:00 AM	04/22/2011 12:00:00 AM		Issued	04/22/2011 12:00:00 AM	ADDRESS	34.03904	-118.23584	First time tenant. Ti on the basement of 3 story appartment BLDG. EPC is for power & Energy. (core & shell were submitted under separate application. 10041-10001-15451)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68993	12041-10000-06137												Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			PC Approved	12/13/2011 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68994	13041-20001-20984	8519 W PICO BLVD	90035	5	132B173  1243	4332028039	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			08/27/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.05369	-118.37695	Plan check for power. First time tenant. Plan check for energy completed under master application.Tenant improvement to add a new restroom and guardrail to an existing retail (2,422 sf). NEW LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT ISSUED UNDER THIS APPLICATION))permit arleady issued under application # 13041-20000-20984	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68995	13041-20000-24848	16027 W VENTURA BLVD #501	91436	5	168B141   538	2261022106	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.15641	-118.48225	Change to lighting only, no new loads, to an existing hi-rise office building.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Permit fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68996	16041-10000-12348	505 S VIRGIL AVE #305	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.0649	-118.28724	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE SUITE 305. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR SUITE 305. TOTAL AFFECTED AREA IS 1175 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
68997	14041-20000-01735	9565 N NATICK AVE	91343	7	201B149   693	2650004014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Expired	02/16/2016 12:00:00 AM	ADDRESS	34.24441	-118.45595	PV1 STANDARD PLAN. TOTAL SYSTEM SIZE 7.5KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
68998	16041-10000-34516	6677 W SANTA MONICA BLVD	90038	4	144B185   674	5532022010	[T][Q]C2-2D-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/17/2016 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	01/19/2021 12:00:00 AM	ADDRESS	34.09085	-118.33573	Plan check for Power and Energey for (new) 695 units apartment with 24,900 SF of retail, 5 stories. There are (5) services in compliance with article 230.2(C).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
68999	13041-10000-09207	10635 N IRMA AVE	91042	2	207A195   188	2557024045	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	09/03/2013 12:00:00 AM	ADDRESS	34.26243	-118.30087	PV1 4.32kw MICRO INVERTER 2 STORY HOUSE. [MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69000	18041-10001-36973	9120 W HILLSBORO DR	90034	5	126B169   662	4302010026	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.0415	-118.38951	Changes to an approved of plans for a residential PV system. changes include replacing the Enphase AC solar combiner box with a 125A Panelboard and revising single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69001	15041-10000-37237	10250 W SANTA MONICA BLVD LOADING-DOCK	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	T-24, NEW LIGHTING AND RECEPTACLES TO A SECTION IN WESTFIELD MALL LOADING DOCK. TOTAL SQ. FT. 25,600. BUILDING PERMIT UNDER APPLICATION #:14016-10000-07923, THEREFORE 2008 T-24 FORMS ARE PROVIDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69002	09041-10002-24360	940 W 35TH ST	90089	9	115-5A209 132	5114013030	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	09/28/2012 12:00:00 AM	ADDRESS	34.02309	-118.28755	Modifications to previously approved set of drawings.  Change to lighting and new circuits and panels     <<<<<USC All Sports Project - Major construction.  P/C is for Power and Energy.  >>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69003	15041-20000-42790	24724 S BROAD AVE	90744	15	039B205   512	7404021012	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/18/2015 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	33.80121	-118.2621	PV1.  Install 7.6 kW AC roof-mounted, utility-interactive PV system.  Central inverter standard plan.  (26) LG Solar LG310NIC-G4 with (1) SolarEdge SE7600A-US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69004	18041-20001-16787	8142 N SUNLAND BLVD	91352	6	189B173    43	2409002032	[Q]C2-1VL-CDO-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM			PC Approved	04/16/2019 12:00:00 AM	ADDRESS	34.2183	-118.36947	"04-16-2019 Changes to an approved set of plans, changes include replace lighting fixture type ""G"" to new led lighting. all changes has been clouded as delta 2. Plan check only"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69005	18041-20002-48686	864 S ROBERTSON BLVD 2nd floor	90035	5	132B169   100	4333015025	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	34.06106	-118.38339	Revisions to approved set.  Lighting and lighting control revisions.  (((REVISION FOR AN APPROVED SET T-24 ONLY.  REMOVING CONTROLLED REC IN OFFICES. DELTA AREV ONLY.ORIGINAL PC # 18041-20000-48686)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69006	15041-20000-30195	201 N FIGUEROA ST 13th floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI to existing commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 5,960.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69007	15041-10000-01978	403 W ADAMS BLVD A-B	90007	9	121-5A205 317	5126017018	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.02746	-118.27394	CHANGE OF USE FROM OUT MEDICAL OFFICE TO PATIENT CLINIC.    INT TI OF EXISTING BASEMENT IN OUTPATIENT CLINIC,  OSHPD3 AMBULATORY SURGERY CENTER PROJECT OF APPROX 11,000sqft, 2-ORTHOPEDIC OPERATING ROOMS, 5-RECOVERY ROOMS, 1-TREATMENT ROOM, STAFF SUPPORT AREAS, AND FAMILY WAITING ROOMS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69008	11041-10000-20359	420 N HENRY FORD AVE	90744	15	030B213   299	7440002***	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	04/23/2012 12:00:00 AM	ADDRESS	33.7753	-118.24095	Replace existing UPS with the new, add  new 6 sub panels to supply power to control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69009	16041-10000-13611	6200 W WILSHIRE BLVD	90048	5	135B177   512	5088015021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	06/06/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.06295	-118.36347	Replace F.A System on (E) 17th story commercial build.  (1) F.A Panel   (1) comm. panel  (72) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69010	16041-20000-32680	5218 E YORK BLVD	90042	14	156A225   400	5478005007	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	12/21/2016 12:00:00 AM	ADDRESS	34.12041	-118.20203	Plan check for installation of roof-mounted solar array on SFD. Interconnect with 200A MSP. Derating main breaker to 150A. (30) EnPhase M250 microinverters. (30) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69011	18041-10001-10653	1019 W ROBIDOUX ST	90744	15	033B201   207	7415015030	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	33.78796	-118.27542	Expedite per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69012	19041-20002-43805	10265 N HADDON AVE	91331	7	204B157   511	2646023038	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.25673	-118.42437	10-11-2019 Changes to an approved set of plan, changes include addition of overcurrent protection and disconnect to Energy Storage. Changes has been clouded. Plan check only permit covered under master application.  Fess $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69013	17041-20001-41376	849-857 N BUNKER HILL AVE	90012	1	135A213   128	5407007007	R4-1	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Apartment			03/04/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.0644	-118.24259	Plan check for power and energy for a lost set of plans. Scope of work has remained the same. (((New 6-story 37-unit apartment building.  1600A 240/120V 3ph-4w service.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69014	18041-10000-46954	1550 N RISING GLEN ROAD	90069	4	147B169   342	5561002035	RE15-1-H-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.10004	-118.38417	PLAN CHECK FOR 4.6KWac PV SYSTEM WITH ENERGY STORAGE SYSTEM CONSISTING OF 1 CENTRAL INVERTER(4.6-TL-US-SZ) WITH 15 MODULES(SC- SERIES MODULES) USING RAPID SHUTDOWN DEVICES AND 1 ENERGY STORAGE SYSTEM(14kWh) TESLA POWER WALL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69015	17041-10000-05974	1700 E STADIUM WAY	90012	1	136-5A213  52	5415014900	PF-1XL	Central	Central City North	Historic Cultural		1977.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	34.06815	-118.24238	Plan check for Title 24 only in existing space, replace existing Outdoor lighting fixtures with LED fixtures. Total area: 234,875 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69016	18041-10000-39055	1660-1660 1/2 W ADAMS BLVD	90007	8	123B197   941	5054005020	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			10/11/2018 12:00:00 AM			PC Info Complete	10/11/2018 12:00:00 AM	ADDRESS	34.03247	-118.29933	TI IN AN EXISTING RESTUARANT. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69017	18041-10000-48684	419 S MCCADDEN PL	90020	4	135B185   283	5507014018	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.06623	-118.33729	Note: $0 per senate bill Ab 1414Plan check for PV1 10KW AC / 9.75 KW DC roofmounted system with (30) modules, (1) central inverter, (3) energy storage systems, and (3) subpanels interconnecting through a new 200-Amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69018	12041-10000-23569	19727 W RINALDI ST	91326	12	210B117   380	2701040039	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	10/20/2012 12:00:00 AM	ADDRESS	34.27504	-118.56356	T.I. to an existing salon.  Load is less than 200 Amps.  PLAN CHECK ONLY for Energy, NO emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69019	12041-10000-20655	1507 N WILCOX AVE	90028	13	147A187   100	5547017036	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.09826	-118.33114	TENANT IMPROVEMENT IN A SMALL RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69020	18041-20000-31130	1611 S LINCOLN BLVD	90291	11	111B149  1351	4241017001	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	01/21/2021 12:00:00 AM		Permit Finaled	02/02/2022 12:00:00 AM	ADDRESS	33.99667	-118.45856	PLAN CHECK FOR NEW 600A SERVICE, 600A DISTRIBUTION BOARD, (5) SUBPANELS, AND T24. TOTAL SQUARE FOOTAGE = 2124 SF IN EXISTING COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69021	14041-10000-11803	6033 S CENTRAL AVE	90001	9	105B209    92	6007007022	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			Verifications in Progress	02/06/2015 12:00:00 AM	ADDRESS	33.98492	-118.25673	PV2 ROOF MOUNTED 3PHASE SYSTEM. TOTAL SYSTEM SIZE 145KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69022	19041-20000-46994	20228 W VIA GALILEO	91326	12	219B113   175	2701043011	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.29488	-118.57462	PV1.  Install 11.725 kW DC / 10.575 kW AC roof mounted grid tied PV system.  (35) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69023	14041-20001-26251	5201 N VAN NUYS BLVD	91403	4	172-5A151 218	2249006020	(T)(Q)C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1288.02	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	PIN	34.16536974	-118.44966386	[[[3/19/15 CHANGES TO APPROVED PER INSPECTOR REQUEST. TITLE 24 CHANGES ONLY. REPLACING 40 FLUORESCENT FIXTURES WITH LEDS]]]PLANCHECK FOR A NEW 3,058 S.F. CAR WASH & TEMPORARY AUTO SERVICE BLDG PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69024	13041-10000-35730	850 S HOPE ST	90071	14	129A209   239	5144020020	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	PIN	34.04556592	-118.25943122	PLAN CHECK FOR POWER AND ENERGY FOR NEW PARKING STRUCTURE. SUBMITTAL FOR PARKING AND RETAIL. BUILDING # 13010-10001-01140	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69025	15041-10001-13550	5101 W JEFFERSON BLVD	90016	10	120B177   707	5049032042	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.02566	-118.35507	Supplemental PC only per inspector. T-24 for outdoor lighting at Jack in the Box 3262. Total area: 24,685 sq. ft. Permit under 15041-10000-13550.<<REPLACE EXISTING EXTERIOR AND PARKING LOT LIGHTS W/L.E.D.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69026	15041-10000-24339	3323 W SAN FERNANDO ROAD	90065	13	153B209   120	5458007012	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.11811	-118.24884	PC FOR ENERGY ONLY. T-24 REMOVE HID LIGHT FIXTURE AND REPLACE WITH LED FIXTURES. SQ FT = 8554	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69027	17041-10001-06248	25835 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM			Reviewed by Supervisor	03/22/2018 12:00:00 AM	ADDRESS	33.78945	-118.29472	SUPPLEMENTAL TO ORIGINAL SET OF PLAN - SCOPE INCLUDES REROUTING FEEDERS FROM FUEL CELL TO EXISTING DISTRIBUTION BOARD ONLY.CHANGES ARE SHOWN UNDER DELTA 5ORIGINAL PLAN CHECK #17041-10000-06248 PC FOR FUEL CELL SYSTEM. INTERCONNECTING TO 2 DIFFERENT SERVICE MEETERS. THIS IS PROJECT 1/2. SPECIFIC FOR ADDRESS 25835 VERMONT. CONTROL SYSTEM AND LOCATION IS SHARED WITH OTHER PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69028	11041-10000-01262	940 E 2ND ST	90012	9	129A217   143	5163006017	M3-1	Central	Central City North	Historic Cultural		2060.40	Electrical	Electrical	Public Safety Only			01/21/2011 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	07/18/2011 12:00:00 AM	ADDRESS	34.04698	-118.23369	New Fire alarm system for apartment complex.  P/C is for Power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69029	11041-20001-12034	15725 W PARTHENIA ST	91343	12	195B141   558	2672011043	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			PC Approved	03/13/2012 12:00:00 AM	ADDRESS	34.22848	-118.47482	Changes from previously approved plans.  Changes include relocate lighting fixtures.  Plan check for energy only.Note: Permit under 11041-10000-12034*****TI TO AN EXISTING SINGLE STORY OCCUAPTIONAL EDUCATION BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69030	10041-10000-12099	9089 N WOODMAN AVE	91402	7	195B153    46	2639032011	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.40	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	07/26/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	PIN	34.23475125	-118.44089019	REMODEL/EXPAND PHARMACY AREA WITHIN A CVS PHARMACYPLAN CHK IS FOR TITLE 24 : LIGHTING CIRCUITS ARE ROUTED THROUGH EXISTING ENERGY MANAGEMENT SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69031	18041-10000-15106	1030 N SWARTHMORE AVE #3-107	90272	11	129B125   834	4423016008	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Closed	05/13/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	"PC FOR FIRST TIME TENANT ""LANDLORD WORK""  TENANT IMPROVEMENT TO RETAIL SPACE IN NEW MALL- PALISADES VILLAGE. FOR POWER AND ENERGY. SCOPE INCLUDES NEW PANEL, CIRCUITS, EQUIPMNET AND LIGHTS. TOTAL AFFECTED AREA 1190 SQ. FT b#18016-10000-12671"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69032	17041-10001-18209	17322 W PARQUE VANOWEN WAY	91406	6	180B133   597	2229008040	(Q)RD3-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM			PC Approved	06/26/2017 12:00:00 AM	ADDRESS	34.19338	-118.51076	Expedite fees only.       Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system.  Total system size = 13.407 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69033	18041-10001-13059	700 WORLD WAY Terminal 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM			Reviewed by Supervisor	12/12/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	DELTA 18 CHANGES TO AN APPROVED SET. SCOPE INCLUDES REPLACING FIVE GAS KITCHEN EQUIPMENT AND ONE WATER HEATER WITH ELECTRIC EQUIPMENT. (PER MZ)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69034	19041-10001-03931	1638 S NORTON AVE	90019	10	126B189   415	5072011021	RD2-1-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.04269	-118.32574	EXPEDITE PER APPLICANT REQUEST>>>>>>>>>>>>PLAN CHECK FOR A NEW ROOFTOP SOLAR SYSTEM  AND ENRGY STORAGE SYSTEM IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES 17 MODULES ( Q-PEAK 305W). ONE CENTRAL INVERTER (DELTA SOLIVIA 5.2) AND ONE 13.5KWH  BATTERY(TESLA POWERWALL). SYSTEM SIZE IS 5.2KWac AND 5.19KWdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69035	10041-20000-25801	1429 S ROBERTSON BLVD	90035	5	132B169  1065	4305014026	C2-1-O	Central	Wilshire	South Robertson		2170.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.05401	-118.38398	Plan check power and energy for yogurt shop. Existing service, new 400A section supplying yogurt shop. In methane zone, no underground penetration.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69036	19041-20000-50760	22829 W COHASSET ST	91307	12	186B097   523	2021016005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	12/23/2020 12:00:00 AM	ADDRESS	34.20588	-118.62444	PV1 PLAN CHECK FOR NEW ROOF PV. SYSTEM SIZE IS 10.95 KW DC/9.6 KW AC. SCOPE OF WORK CONSISTS OF (30) PV MODULES WITH MICROINVERTERS, AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69037	18041-20000-20277	5969 N LANKERSHIM BLVD	91601	2	177B169   854	2338009005	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Issued	06/01/2018 12:00:00 AM	ADDRESS	34.17919	-118.38349	PLAN CHECK FOR TITLE 24 ONLY FOR - REMOVE HID FIXTURES, AND REPLACE WITH NEW LED LIGHTING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69038	17041-10002-39640	5959 W CENTURY BLVD	90045	11	090B169    13	4124030040	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	08/23/2021 12:00:00 AM	ADDRESS	33.94571	-118.38857	DELTA 4 & 5 CHANGES TO APPROVE PLANS . CHANGES INCLUDE ADDING 1 TRANSFORMER AND 1 PANEL. CHANGE TO T-24 AND SLD. (FEE ESTIMATE)<<<<ORIGINAL: PC FOR Adaptive re-use of an existing 13-story office building (226,150 s.f. TYPE IA) . Change of use to  a 401 gustroom  hotel with amenities.SCOPE INCLUES NEW GENERATOR, FIRE PUMPS, PANELS AND CIRCUITS. TOTAL  AFFECTED AREA 261,000 (INDOOR AND OUTDOOR)>>>>B#16016-10000-29872	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69039	16041-30000-29379	3831 S HUGHES AVE Parking P1-P4	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.02242	-118.39823	Plan check for Title 24 only T.I. in existing parking structre 4 levels P1, P2, P3&P4. Total lighting area: 93,470 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69040	19041-10000-16073	5933 N MONTEREY ROAD	90042	14	150A231   152	5312008017	[Q]C4-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	Apartment			05/01/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	01/13/2021 12:00:00 AM	ADDRESS	34.10549	-118.1847	NEW 3-STORY 13-UNIT APARTMENT BUILDING WITH GROUND FLOOR RETAIL AND PARKING. NEW 800 AMP SERVICE.BULDING PERMIT: 18010-10000-01253	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69041	17041-20000-00128	1200 N BEL-AIR ROAD	90077	5	147A153   602	4370029013	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.09497	-118.44366	New three story SFD with 208Y/120V 1600A service.  Plan check for power only.  Electrical permit issued under building combination permit 14010-30000-02037.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69042	17041-20001-29320	23700 W KIVIK ST	91367	3	171B093   365	2047004007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.16558	-118.64227	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.1 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69043	17041-20000-06657	1871 N STANLEY AVE	90046	4	150B177   457	5551012025	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			PC Info Complete	10/17/2017 12:00:00 AM	ADDRESS	34.10407	-118.35757	Plan check for power only. Project site is a new 2-story single-family home with a habitable basement.Note 1: Building permit has been issued under 14010-30000-04159Note 2: There is a 2-story accessory living quarter that has been included as part of this electrical plan check. A separate electrical application has been created under 17041-20000-06662 with building application number 14010-30000-04160.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69044	11041-10000-07313	940 W 35TH ST	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Finaled	06/20/2012 12:00:00 AM	ADDRESS	34.02309	-118.28755	NEW FIRE ALARM SYSTEM FOR A SPORT CENTER. EPC IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69045	16041-20000-04970	758 N NEW HIGH ST	90012	1	133-5A215  41	5408027005	C2-2	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Closed	10/11/2017 12:00:00 AM	ADDRESS	34.06161	-118.23772	Plan check for power only. New 800 service consolidation/upgrade for vacant two story commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69046	14041-10000-27466	8560 W DAY ST	91040	7	204B189   938	2560035028	RE40-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/27/2014 12:00:00 AM	ADDRESS	34.25415	-118.31992	PV1, INSTALL 8.16 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(32) MODULES: KYOCERA KD255GX-LFB3(2) ABB PVI-5000-OUTD-US-Z-A & PVI-3.0-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69047	15041-20001-12916	17547 W GILMORE ST	91406	6	180B129   821	2229027003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM			PC Approved	05/27/2015 12:00:00 AM	ADDRESS	34.18777	-118.51596	changes to approved set of plans. change to wire size from #8's to #10's. ampacity OK. change in site plan to include disconnect at garage location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69048	19041-10000-43673	6535 W IMPERIAL HWY	90045	11	087B165   123	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM			PC Info Complete	02/27/2020 12:00:00 AM	ADDRESS	33.93175	-118.40294	Electrical Plan Check for a new 3000Amp 480/277 3 phase 4 wire Service at imperial cargo complex at LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69049	17041-10000-30156	8319 S MAIN ST	90003	9	099B201  1376	6031036029	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2397.02	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	33.96357	-118.27404	TI TO EXISTING MULTI TENANT BUILDING. UPDATING SERVICE AND DISTRIBUTION TO RESERVE AND REBUILD TENANTS. REFEED SOME EXISTING LOADS. NEW 800 SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69050	19041-30000-50041	20433 W LONDELIUS ST	91306	3	195B109   211	2781006011	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.22919	-118.57879	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10KWac, SCOPE OF WORK IS 36 MODUKES (HANWHA Q-CELL SC315) WITH OPTIMZERS (SE P400), A CENTRAL INVERTER (SE10000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69051	18041-10000-23697	11813 W DOROTHY ST 1-9	90049	11	129B145   211	4265017003	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	03/23/2021 12:00:00 AM	ADDRESS	34.05179	-118.46729	FULL PLAN CHECK FOR POWER AND ENERGY FOR (N) 4-story 9-unit apartment building over 1-level subterranean garage. - SERVICE SIZE = 800A, TOTAL AFFECTED AREA = 8925 ST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69052	15041-10000-35078	118 S ASTRONAUT ELLISON S ONIZUKA ST	90012	14	130-5A213 136	5161016025	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	08/10/2018 12:00:00 AM		Issued	08/10/2018 12:00:00 AM	ADDRESS	34.05046	-118.24184	PC FOR POWER AND ENERGY. NEW 9 STORY 77 UNIT MIXED USE APARTMENT BUILDING OVER 3 LEVEL SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES A NEW 4000A 120/208V 3 PHASE 4 WIRE SERVICE, NEW PANELS, NEW CIRCUITS,  AND NEW LIGHTS. TOTAL AFFECTED AERA IS 125424 SQ. FT. B#15010-10000-02939	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69053	13041-20000-28883	1201 W 5TH ST #800	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.05429	-118.25967	Change to lighting in an existing high-rise office building.    Load is less than 400 amps.  PLAN CHECK ONLY for Energy.  All emergency lighting is existing with no change.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69054	11041-10000-07967	5960 N FALLBROOK AVE	91367	3	183B097   578	2024038005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Closed	06/12/2014 12:00:00 AM	ADDRESS	34.17907	-118.6231	ALTERATIONS IN  THE FALLBROOK VETERINARY CLINICPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69055	10041-10000-09195	1730 W MANCHESTER AVE	90047	8	097-5A193 336	6037014024	P-1, [Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM			Verifications in Progress	08/10/2010 12:00:00 AM	ADDRESS	33.9598	-118.3078	interior improvement/remodeling of a Ralphs supermarket	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69056	19041-10000-28612	11266 W SANTA MONICA BLVD	90025	11	129B149   462	4261008004	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.04647	-118.44778	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69057	14041-20000-18509	13159 N BRADLEY AVE	91342	7	222B145    22	2501006029	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.30904	-118.46482	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC. USING CENTRAL TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. 24 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69058	17041-10000-17051	300 WORLD WAY SPACE 333	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM			Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	33.94502	-118.40714	TENANT IMPROVEMET FOR NEW BAR  WITH KITCHEN., new lighting. pc for t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69059	15041-10000-00392	6201 W HOLLYWOOD BLVD 110	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	Full plan check for first time tennant assembly area as a gym.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69060	16041-20000-43880	3411 E 15TH ST	90023	14	117A225   110	5192013032	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Issued	12/15/2016 12:00:00 AM	ADDRESS	34.01586	-118.20638	Plan check for power only. New 600A service for existing commercial building. New new loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69061	19041-20000-37564	3610 S SAN PEDRO ST	90011	9	117A207   347	5121009001	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	05/29/2024 12:00:00 AM	ADDRESS	34.01304	-118.26657	Power, lighting, and distribution for 2-story commercial office renovation.  Change of use from manufacturing to office on 2nd floor per building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69062	15041-20000-08133	3718 N VANTAGE AVE	91604	2	162B165   889	2369009021	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2015 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.13832	-118.39554	Plan check for PV1 roof mounted 4.75kw system with 19 microinverters and 2 strings.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69063	13041-10000-23462	4700 W VANTAGE AVE	91607	2	168B165   717	2356037017	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM	09/04/2013 12:00:00 AM		Permit Finaled	09/11/2013 12:00:00 AM	PIN	34.15584298	-118.39734877	PV1.  Install 4.32 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69064	19041-20000-08777	12142 W STAGG ST	91605	2	189B165   894	2307011015	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.21199	-118.39795	PV1.  NEW 10.8KW AC ROOFTOP PV SYSTEM ON (E) SFD. SCOPE OF WORK INCLUDES (30) 360W SUNPOWER MODULES WITH INTEGRATED MICROINVERTERS,  AND (1) 125A PV DISTRIBUTION PANEL.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69065	17041-10000-37032			5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM			PC Approved	10/16/2017 12:00:00 AM	PIN	34.05846728	-118.442909	PC for T24 only for new lights in lobby, basement and outdoor in high rise building. Installed load under 400A. Total area indoor is 24607sqft and 24744sqft outdoor. Building# 17014-10000-04521.B# 17014-10000-04521	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69066	13041-10000-16741	111 E UNIVERSAL HOLLYWOOD DR # 350	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM			PC Approved	06/24/2013 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING OFFICES PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69067	18041-20000-46640	13126 N MESA VERDE WAY pv1	91342	7	225B165    19	2580018***	RD6-1XL	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.31125	-118.40648	pv1install roof mounted ppv system sized 5KW AC interconnected with msp.this is plan check only.  permit fees paid under application number 10841-90000-40268	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69068	17041-10000-32976	4632 W HOLLYWOOD BLVD 1-4	90027	13	147B197   478	5542014008	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.09992	-118.2903	CONVERTING 2 APT. UNITS TO 3 GUEST HOUSE UNITS AND 1 DWELLING UNIT TO BE CONSIDERED BOARDING HOUSE ON THE 2ND FLOOR AND ADD A NEW DECK TO 2ND FLOOR. PC FOR T24 ENERGY ONLY FOR HOTEL/ MOTEL REQUIREMENTS COMMON AREAS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69069	18041-20001-46748	966-974 S KENMORE AVE	90006	10	129B197    81	5078005016	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Apartment			07/02/2019 12:00:00 AM			PC Info Complete	07/02/2019 12:00:00 AM	ADDRESS	34.05364	-118.29671	7/2/2019changes to an approved set of plans.  changes to add fire pump and booster pump, reconfigure unit floor plans, unit feeders and elevator rating.  ((((FULL PLAN CHECK FOR 6 STORY, 50 UNIT APARTMENT. SERVICE SIZE 1600A, 120/208V, 3PH, 4W. TOTAL AREA: 30,061 SQ.FT((B# 18010-10000-03412))))))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69070	17041-10000-09955	16730 W CALLE DE CATALINA	90272	11	138B117    79	4431042***	(Q)RD3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM			Reviewed by Supervisor	04/17/2017 12:00:00 AM	ADDRESS	34.076	-118.55127	PC for a Ground mount PV system, 36 solar modules and total system size of 10 KW, central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69071	16041-10000-00714	1925 W 66TH ST	90047	8	102B193   183	6016012020	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	33.97924	-118.31202	PV1 roof mounted solar system installation interconnected with the main service. Inverter rating: 3.6 kw, (14) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69072	15041-10000-24052	1500 W PACIFIC COAST HWY Bldg A	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			07/29/2015 12:00:00 AM	08/21/2015 12:00:00 AM		Permit Finaled	04/05/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	NEW FIRE ALARM SYSTEM WITH 77 DEVICES FOR A New 3-story, 28 unit apartment with garage, Typev VA construction. CONTRIOL PANEL IS ON RE RM APPLICATION # 15041-10000-24054.-	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69073	18041-20000-45073	4924 N LANKERSHIM BLVD	91601	2	168B173    13	2353018014	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Re-Activate Permit	10/24/2019 12:00:00 AM	ADDRESS	34.16073	-118.37187	Plan check for power only. Project site is an existing commercial building. Project scope is the replacement of multiple existing service with a single 600 Amp service and the installation of (1) new sub panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69074	19041-10000-23556	1409 W VERNON AVE	90062	8	111B193    59	5021017902	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2316.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Issued	06/20/2019 12:00:00 AM	ADDRESS	34.00384	-118.30061	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69075	14041-10000-33343	5326 E YORK BLVD	90042	14	156A227   462	5478004023	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM			PC Info Complete	12/02/2014 12:00:00 AM	ADDRESS	34.1198	-118.19937	new 2-stories office building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69076	17041-10000-36040	7843 N LANKERSHIM BLVD SUITE #101	91605	6	189B169   517	2310025***	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	08/07/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	FIRST TIME OCCUPANCY IN A NEW CLINIC. EPC FOR POWER AND ENERGY.MODIFICATION FORM WAS SUBMITTED TO SEPERATE THE FIRE ALARM SYSTEM.CORE AND SHELL APPROVED UNDER 15041-10000-34860.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69077	17041-20000-09584	20362 W WELLS DR	91364	3	168B113   212	2174003050	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Issued	03/24/2017 12:00:00 AM	ADDRESS	34.15779	-118.57662	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.8.16kW ungrounded system. (34) EnPhase M250 microinverters. (34) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69078	13041-10001-04818	680 S BERENDO ST	90005	10	132B197   130	5094008010	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			03/04/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.06064	-118.294	ON SHEET E-1.0 FOR THE SITE PLAN, THE ROUTING OF THE SERVICE CONDUCTORS WAS CHANGED DUE TO STRUCTRAL CONSTRAINTS. THE DOOR TO THE ELECTRICAL ROOM IS ON THE OPPOSITE SIDE OF THE ELECTRICAL ROOM. PROPOSED 171 UNIT APARTMENT W/ GARAGE. 6 STORIES OF TYPEIIIA CONSTRUCTION W/ 3 LEVELS (2 BASEMENT AND 1ST FLOOR) OF TYPE I GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69079	10041-20000-10962	445 S FIGUEROA ST 28th Floor	90071	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00, 2077.10	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	02/01/2011 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check T-24 Energy general/emergency lighting of office TI on the 28th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69080	14041-20000-30745	22664 W INGOMAR ST	91304	12	189B097   957	2013032010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/10/2014 12:00:00 AM	ADDRESS	34.21166	-118.62128	PV1Using standard plan.Install roof-mounted solar array on SFD. Interconnect with 200A MSP. Derating main breaker to 150A.System size: 5.28kW. Ungrounded system.22 EnPhase M250 microinverters with 22 270W pv modules across two strings (11+11).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69081	17041-20000-07282	13236 W AETNA ST	91401	2	177B157   783	2331029013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.18021	-118.42153	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with 200A MSP.Derating main breaker to 175A. 9.84kW ungrounded system. (40) EnPhase M250 microinverters. (41) 280W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69082	13041-20000-31673	20133 W SHERMAN WAY	91306	3	183B113    24	2114019009	C4-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.20128	-118.57238	T.I. to an existing retail space, new 1600 amp switch board.  Change to lighting, Tailored Method. DD's discount	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69083	17041-20000-21803	131 N DELFERN DR	90077	5	141B157   125	4358005021	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.08018	-118.4287	PLAN CHECK ONLY FOR SINGLE FAMILY RESIDENCE. REMODEL OF  EXISTING SFD, GUEST HOUSE AND POOL HOUSE. ELECTRICAL PERMIT FEES HAVE BEEN PAID FOR UNDER THE FOLLOWING BUILDING PERMITS: 17014-30000-00371 , 17016-30000-07023, 17014-30000-01034	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69084	14041-20000-20708	7669 N OSO AVE	91306	3	189B113  1435	2114001060	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.21046	-118.57559	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(21) TRINA SOLAR TSM-255 MODULES(1) POWERONE PVI-4.2KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69085	13041-10000-05692	4104 W SEA VIEW DR	90065	14	151-5A221 247	5471007040	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Expired	03/31/2015 12:00:00 AM	ADDRESS	34.10868	-118.21461	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL YSTEM SIZE 4.42KW. USING TRANSFORMERLESS INVERTER, WITH POWER OPTIMIZERS. 17 MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69086	17041-30000-43732	7335 N VAN NUYS BLVD #121-122	91405	6	186B149   645	2218017026	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.20401	-118.44899	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,120 sq. ft.Note: Building application has been generated under 17016-30000-32040	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69087	11041-10000-18517	1371 W JEFFERSON BLVD	90007	8	120B197   610	5040023027	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	Commercial			08/31/2011 12:00:00 AM			Corrections Issued	10/18/2011 12:00:00 AM	ADDRESS	34.02565	-118.29672	REPLACEMENT OF AN EXISTING 50 HP FIRE PUMP WITH A 40 HP FIRE PUMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69088	16041-10002-39052	18133 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	02/23/2024 12:00:00 AM	ADDRESS	34.16603	-118.52861	09-15-2017 Changes to an permitted set of plan. Changes include added dedicated outlet and relocated water heater and circulating pump and update panel 4ECL. Changes apply to delta 1,2,3 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69089	17041-20000-04869	1999 S AVENUE OF THE STARS 5th-6th Floors	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	05/15/2017 12:00:00 AM		Issued	05/15/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI to (E) commercial tenant space private offices.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69090	19041-20000-22580	4738 N LAUREL CANYON BLVD	91607	2	168B165   594	2355014029	P-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.15676	-118.39628	T24 PLAN CHECK NEW LIGHTS AND OUTLETS FOR REDUCED FLORAL AREA AND NEW BAR AREA. TOTAL SQUARE FOOTAGE = 1736 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69091	11041-10000-13852	9301 N TAMPA AVE 196	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM	08/12/2011 12:00:00 AM		Permit Finaled	09/12/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	COMMERCIAL TENANT IMPROVEMENT TO AN EXISTING RETAIL SPACE FOR A NEW VANS SHOE STORE; PARTITIONS, REFLECTED CEILING, STORE FIXTURES, NEW SHELVING, NEW MECHANICAL UNIT PLAN CHK IS FOR TITLE 24 ;PERMIT FEE IS IN INSPECTION FEE SCHEDULE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69092	10041-20000-03197	14006 W RIVERSIDE DR #201S	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/23/2010 12:00:00 AM			PC Info Complete	02/23/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	energy plan check # 201S	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69093	16041-20000-28932	18100 W PARTHENIA ST	91325	12	195B125   858	2786001021	C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.2285	-118.52784	Plan check for energy only. Interior and exterior TI of Taco Bell restaurant. New lighting (incl. emergency). 1,664sqft indoor. 478sqft outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69094	14041-10001-00964	380 WORLD WAY Space T62	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	Delta 10 changes to permtted set of plans; panel schedule updated to show 1ph 2-pole water heater and panel load calculations revised First time tenant for LAX (Tom Bradley), Space T62-R.  Install new panel and lighting.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69095	12041-10001-25399	3584 S FIGUEROA ST SUITE 5	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/02/2013 12:00:00 AM			PC Approved	01/02/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	SUPPLEMENTAL: CHANGE OF LIGHTING PENDANT TO 100WDELTA 5 AS-BUILT REVISIONPLAN CHECK ONLYTI IN COMMERCIAL SPACE CHANGED TO PIZZA  SHOPFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69096	17041-10002-45515			4	168B177   412	2420006017	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM			PC Approved	05/11/2018 12:00:00 AM	PIN	34.15842403	-118.3579602	PC FOR CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLATION OF SOLAR REDAY PANEL. THIS PC ONLY. PERMIT PULLED UNDER MASTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69097	18041-10000-02083	4313 S VAN BUREN PL	90037	9	114B197  1152	5020009009	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2018 12:00:00 AM	01/31/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.00512	-118.29708	"PC for rooftop 7.63kW(ac) solar for SFD. Installing 32 modules (9.6kW DC) with IQ-6 Plus microinverters and combiner box.""COMPLY WITH DEPARTMENT ORDER effective date03/12/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"" CEIS Case Number is554332."	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69098	13041-10000-29515	10711 N FULLBRIGHT AVE	91311	12	207B113    82	2707004021	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	12/06/2013 12:00:00 AM	ADDRESS	34.26489	-118.57722	PV1.  Install 12.5 kW DC roof-mounted solar array, interconnect with main service panel.  Multiple inverters. 50 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69099	11041-10000-17496	7760 W HOLLYWOOD BLVD	90046	4	147B177   362	5551014018	[Q]R3-1XL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Apartment			08/19/2011 12:00:00 AM	02/24/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.10151	-118.35846	"NEW 600A SERVICE, NEW PANEL ""D"", AND NEW A/C UNITS,EXIST. BLDG.  <PERMIT FOR 36 NEW CIRCUITS PAID 11041-10001-08072 & 11041-10002-08072  TO BE VERIFIED IN THE FIELD.>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69100	16041-20001-27506	18644 W SHERMAN WAY Bldg E	91335	3	183B121   150	2126005027	[Q]R1-1L-CDO-RIO, [Q]R3-1L-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.20095	-118.5401	Plan check for energy only. Restroom remodels. New lighting, new receptacles. 743sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69101	17041-20001-31645	9665 N DALE AVE	91040	7	201B177   387	2544004011	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	09/15/2017 12:00:00 AM	ADDRESS	34.24506	-118.357	Expedited plan check fee. PV1.  Install 9.625 DC kW roof mounted grid tied system.  (35) modules with (2) string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69102	12041-10000-27055	7318 W 87TH PL	90045	11	096B157   725	4119023004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	33.9579	-118.42309	PV1 SOLAR INSTALLATION 3.4KW ROOF MOUNTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69103	17041-20000-45360	9745 N SALOMA AVE	91343	7	201B149   384	2650006011	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.24771	-118.45774	Plan check for solar pv system w/roof-mounted array on SFD.System size: 3.6kW ungrounded. (13) 330W pv modules.Existing 4kW pv system on site.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69104	12041-20000-16256	11740 W SAN VICENTE BLVD	90049	11	129B145    75	4265006074	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	08/23/2012 12:00:00 AM	ADDRESS	34.05308	-118.4669	Install lighting and power for remodeled pizza restaurant.  Plan check for T-24 lighting compliance only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69105	15041-10000-38799	13150 W SATICOY ST	91605	2	186B157   228	2303023035	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/07/2016 12:00:00 AM	ADDRESS	34.20757	-118.42001	T-24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL SQ. FT. 6880	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69106	19041-10000-03855	920 W BLOOM WALK	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	34.01996	-118.28938	Full plan check for a change of use from library to classrooms/workshop. Scope inlcudes new lighting and equipment with (1) 800-Amp distribution board.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69107	17041-20001-18116	16916 W PARTHENIA ST	91343	12	195B133   471	2689018022	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.22834	-118.50096	6.5.2017 - Plan check for installation of exit signs. (4) new exit signs and (5) new receptacles for massage parlor.=====New circuit for water heater / outlet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69108	19041-20000-37892	18831 W MUIRKIRK DR	91326	12	219B121    71	2820004001	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.29661	-118.54442	PV1. INSTALL 9.425 KW DC SOLAR SYSTEM WITH (29) MODULES AND OPTIMIZERS AND (1) INVERTER (SE7600H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69109	17041-10000-04492	1001 W E ST BLDG 7	90744	15	030B201   837	7417012925	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM				Plan check for new Fire alarm for new appartment building. Total fire alarm devices: 34 and 1FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69110	19041-10000-53150	6600 N TOPANGA CANYON BLVD 98C	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	07/07/2020 12:00:00 AM		Issued	07/07/2020 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24 PLAN CHECK FOR A TI TO AN EXISTING SPACE.. TAILORED METHOD USED. TOTAL AFFECTED AREA IS 1978 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69111	17041-10000-08412	13617 W FOOTHILL BLVD	91342	7	222B157   126	2513009054	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.30731	-118.42983	PC for title-24, Outdoor. Removing HID fixutres and replacing them with LED fixtures. Area: 25,400 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69112	17041-10000-25683	12500 W SHERMAN WAY	91605	2	183B165    48	2324034018	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.20097	-118.40562	TITLE 24 PLAN CHECK TO REPLACE EXISTING (7) FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA = 12875 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69113	19041-20000-41049	11881 W TERRA VISTA WAY #103	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.28607	-118.3907	PV1. INSTALL 2.03 KW DC PV SYSTEM WITH (7) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69114	13041-10000-17139	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			06/27/2013 12:00:00 AM			PC Approved	07/17/2013 12:00:00 AM	ADDRESS	34.06664	-118.46903	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. REMODEL OF EXISTING KITCHEN AND DINING AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69115	12041-20000-11919	2970 W OLYMPIC BLVD #305	90006	10	129B197   249	5078017021	[Q]C2-1	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM			Plans on Hold	05/25/2012 12:00:00 AM	ADDRESS	34.05241	-118.29951	nedical office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69116	18041-20000-43743	9201 N MASON AVE	91311	12	198B109   111	2748041013	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	06/18/2020 12:00:00 AM	PIN	34.23841729	-118.5804491	Plan check for power and energy. Project site is a new 1-story warehouse. Work includes a 1,600 Amp service and a total lighting of area 61,774 sq. ft.Note: Building application has been generated under 18010-20000-00336	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69117	17041-10000-36217	6000 S CRENSHAW BLVD	90043	8	105B185   413	4006003001	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.01	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			PC Info Complete	01/11/2018 12:00:00 AM	ADDRESS	33.98518	-118.33056	T-24, PC FOR ENERGY ONLY. INTERIOR ALTERATIONS INSIDE A RESTAURANT-TACO BELLIN THE KITCHEN AND DINING AREAS LUMINAIRES ARE CHANGED TO LED TYPES AND USING EXISTING BRANCH CIRCUIT TOTAL AFFECTED AREA IS 1560 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69118	17041-10003-25740	4151 W PROSPECT AVE BLDG G	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM			PC Approved	06/20/2019 12:00:00 AM	ADDRESS	34.10191	-118.28217	"DELTA ""2"" CHANGES ONLY TO UPDATE PLANS TO MATCH THE EXISTING CONDITIONS. UPDATE STAGE 2 DISTRIBUTION BOARD OCPD TO 1000A.REVISE NUMBER OF WIRES ON 2 FEEDERS. PLAN CHECK ONLY <<<PC FOR POWER RPLACING TWO SWITCH BOARDS 800 AND 1600 AMPS  240V WORK DONE IN  BUILDING  ""G""  STAGES ONE AND TWOSCOPE INCLUDES  REPLACING EQUIPMENT AND INSTALLING NEW CIRCUITS>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69119	15041-20000-41927	375 N LA CIENEGA BLVD Suite 3	90048	5	138B173    80	4337012068	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Approved	12/14/2015 12:00:00 AM	ADDRESS	34.07806	-118.37692	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement/change of use from retail to fitness center. Total lighting area = 2,424 sq. ft.Note: Building permit has been pulled under 15016-10000-15144Note: Permit has been pulled under 15041-40000-39581	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69120	16041-20000-03393	17215 W BULLOCK ST	91316	5	177B133    24	2255008003	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	34.17989	-118.50828	Install a roof-mounted solar array on a SFD. Using standard plan. Interconnect with a 200A MSP.System size: 5kW. Ungrounded system. (14) 255W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69121	16041-10000-01760	827 E JEFFERSON BLVD	90011	9	117A207   220	5120028023	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.0143	-118.26244	T-24, TI TO A COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHITNG AND RECEPTACLES. TOTAL SQ. FT. 5460.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69122	11041-20000-27518	2921 W LOS FELIZ BLVD Bldg F	90039	13	157-5A207 376	5594006024	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	04/26/2012 12:00:00 AM	ADDRESS	34.12622	-118.26388	Existing restaurant space (Building F) being occupied by a new tenant (Soup Plantation).  Adding 6 new panels and new circuits.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69123	18041-10001-37821	6600 N TOPANGA CANYON BLVD #2076	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	DELTA CHANGES TO APPROVED PLANS.PLAN CHECK ONLY. PERMIT TO BE ISSUED ON: 18041-10000-37821<<<TI IN AN EXISTING RETAIL SPACE. T-24 ENERGY ONLY. >>> BLDG PERMIT: 18016-10000-32092	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69124	10041-10000-05352	1999 S AVENUE OF THE STARS 32nd floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM	04/22/2010 12:00:00 AM		Permit Finaled	05/13/2010 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI in an existing office area on the 32nd floor.  Plan Check is for title 24 energy calcs.  RE-Locate 12 existing light fixtures due to changes in the T-Bar ceiling.  No New Lights are added.  Existing emergency lights and exit signs were not modified.  Permit is for the relocated light fixtures, motion sensors & receptacles on existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69125	18041-10000-38910	10861 W QUEENSLAND ST	90034	5	120B157   231	4254007039	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.02762	-118.42031	PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER (SE7600H-US) WITH 31 PANELS USING P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69126	15041-20001-34990	23340 W OXNARD ST	91367	3	177B093   841	2041006016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2015 12:00:00 AM			PC Approved	11/03/2015 12:00:00 AM	ADDRESS	34.17776	-118.63592	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.5 kWac and consists of (42) modules, (42) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69127	14041-20000-17641	953 E 3RD ST	90012	14	129A217   161	5163006020	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	PIN	34.04633031	-118.23332713	PARTIAL FLOOR TENANT IMPROVEMENT ON FIRST AND SECOND FL OF (E) 2-STORY OFFICE BUILDING. PC FOR NEW LIGHTING. T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69128	17041-10000-33074	8924 S BELLANCA AVE	90045	11	096B169  1057	4125010010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	33.95536	-118.38038	NEW ABOVE GROUND GASOLINE FUEL TANK WITH FUEL DISPENSERS. PC FOR POWER ONLY FOR HAZARDOUS LOCATION. INSPECTOR TO VERIFY CONNECTED LOAD AT JOB SITE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69129	13041-10001-30945	10922 N WHITEGATE AVE	91040	7	208-5A195  35	2552017012	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.2677	-118.30519	Expedited RSES plan check per applicant request. (((PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 18 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69130	19041-10000-02308	687 S HOBART BLVD SUITE #C	90005	10	132B193   184	5093006035	(T)(Q)C2-2	Central	Wilshire	Wilshire Center-Koreatown		2125.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Issued	03/12/2019 12:00:00 AM	ADDRESS	34.0605	-118.30557	FIRST TIME TENANT, COFFEE SHOP IN SUITE #C. FULL PLAN CHECK. 1335 SQR FT.BUILDING PERMIT: 18016-10000-35777	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69131	17041-10000-38204	19900 W PLUMMER ST	91311	12	198B113    85	2761040010	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.24259	-118.56723	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69132	14041-10001-21047	4346 N EMPRESS AVE	91436	5	165B133   154	2291001007	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.15036	-118.50378	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST,{PV1, INSTALL 13.5 KW DC ROOF-MOUNTED SOAR ARRAY INTERCONNECT WITH MAIN SERVICE PANEL.(54) MODULES: KYOCERA KD250GX-LFB3(2)INVETERS: SOLAREDGE  SE5000A-US-ZB-U & SE6000A-US}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69133	19041-20000-07788	18313 W MINNEHAHA ST	91326	12	207B125   605	2731013047	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.26011	-118.5323	PLAN CHECK FOR NEW 5KW(TESLA POWERWALL) ENERGY STORAGE SYSTEM AND A NEW 200A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69134	14041-20001-22954	4142 S CHASE AVE	90066	11	108B157   110	4231020021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	33.9957	-118.42981	Addition of AC disconnect to front of house.  $0 plan check fee is due to State Senate Bill SB-1222.(((PV1.  Install 5.00 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69135	16041-10000-28716	12100 W WILSHIRE BLVD 15th FLR	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	10/29/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	TI TO CORRIDOR ON 15TH FLOOR. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69136	18041-10000-37013	14308 W NORDHOFF ST	91402	6	195B153    17	2639021023	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.23518	-118.44405	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69137	14041-10000-17141	10800 S PERSHING DR	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	33.93744	-118.43216	Plan check for power and lighting.  Total area = 954,623 sq. ft.On site electrical distribution system for new service in LAX.Title 24 fee is exempt, scope of work is on the airfield.  Applicant will return to pay adjusted fees including expedite fee.  Actual fees will be slightly higher.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69138	16041-20000-02406	7709 W FOOTHILL BLVD	91042	7	204B197   640	2558008015	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	12/30/2016 12:00:00 AM	ADDRESS	34.25695	-118.3002	PV2. System is being installed on a commercial building (medical). Install roof mounted PV system sized 15 kWac and consists of (3) inverters, (45) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69139	18041-10001-09060	5722 W JEFFERSON BLVD	90016	10	120B173   311	5047018002	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/11/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	34.02588	-118.36994	******* THIS PLAN DOES NOT INCLUDE EGRESS ANALYSIS            **************** EGRESS ANALYSIS TO BE APPROVED UNDER SUPP.  PLAN CHECK**********THIS IS PLAN CHECK ONLY PERMIT PULLED 18041-10000-09060.PLAN CHECK FOR ENERGY ONLY FOR TI WITHIN AN EXISTING FACILITY - NEW DESIGNER IS USED FOR LIGHTING PLAN PC FOR TI INSIDE AN EXISTING FACILITY. T-24 ONLY. SCOPE INCLUDE NEW LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 6090 SQ.FTB# 17016-10000-33624	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69140	12041-20001-30537	9401 N CORBIN AVE	91324	12	198B117    94	2761040015	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.24143	-118.56249	Changes to panels, removal of most loads. Plan check was mostly for series ratings.Plan check for power and energy. Core and shell. 2450 conditioned and 1456 unconditioned.  Existing Low-rise Commercial Building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69141	17041-20001-41196	4488 N VISTA SUPERBA DR	90065	14	159A215    28	5679019022	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM			PC Approved	09/24/2018 12:00:00 AM	ADDRESS	34.132	-118.23642	expeditepv1install roof mounted pv system sized 3.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69142	19041-10000-23642	9950 N BALBOA BLVD	91325	12	204B133   695	2685007015	A2-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.25194	-118.50219	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69143	17041-10000-11426	300 WORLD WAY TER 2-TER 3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	12/18/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	T-24 FOR A COMMERCIAL LOUNGE/OFFICE SPACE IN LAX TERMINAL 2 AND 3. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3112.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69144	15041-10000-29019	910 E 61ST ST	90001	9	105B209   123	6007008003	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	33.98432	-118.25922	NEW 800A OVERHEAD 120/240V DELTA SERVICE AND PANELBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69145	19041-20001-13909	15732 W LASSEN ST	91343	12	201B141   225	2671002005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM			PC Approved	04/25/2019 12:00:00 AM	ADDRESS	34.24994	-118.47498	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, CHANGE OF 20A PV BREAKER TO 30A PV BREAKER*original 19041-90000-13909*Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69146	13041-10002-23823	1901 W 7TH ST	90057	1	132A203   154	5142002900	C2-2, C2-4, M3-1	Central	Central City North, Westlake	Historic Cultural		2089.02	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.05562	-118.27458	"DIST BD ""DS"" AMPERE RATING CHANGED TO 600A;PANEL CIS NOW A SUBPANEL OF PANEL AC.NO CHANGES IN THE TOTAL LOAD (((((((((PROPOSED CHANGE OF USE FROM AN EXISTING RETAIL SPACE TO A  7626 SF RESTAURANT. TENANT IMPROVEMENT TO CREATE RESTAURANT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69147	19041-10000-41088	3150 E PICO BLVD	90023	14	118-5A223 160	5169003009	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.01782	-118.21202	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY INDOOR/ OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69148	15041-20000-21457	1977 N COLDWATER CANYON DR	90210	4	150B161   104	4387022019	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Expired	08/01/2017 12:00:00 AM	ADDRESS	34.10728	-118.4057	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (33) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69149	15041-20000-15190	1055 W 7TH ST 3rd Floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	06/08/2015 12:00:00 AM		Permit Finaled	10/22/2015 12:00:00 AM	ADDRESS	34.0507	-118.26334	Title 24. TI to existing commercial building (LA Care offices). Plan check for energy only. Adding new lighting including emergency. Total sqft. 18,135	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69150	13041-10000-27405	5415 S CENTRAL AVE 101-102	90011	9	108B209   707	5103020013	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Apartment			10/02/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	33.99296	-118.25677	FIRE ALAM FOR NEW BUILDING. 1 PANEL. 20 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69151	18041-30000-39980	1201-1205 N ALVARADO ST	90026	13	139-5A207  22	5402033025	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1956.00	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.07832	-118.26326	PLANCHECK FOR POWER AND ENERGY.  CORE AND SHELL REMODEL TO 2 STORY COMMERCIAL SPACE.BUILDING PERMIT # 16016-10000-30798	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69152	19041-10000-16990	21040 W NORDHOFF ST	91311	3	195B105    24	2779048004	[Q]MR2-1, [T][Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			Corrections Issued	05/11/2019 12:00:00 AM	ADDRESS	34.23524	-118.59224	PLAN CHECK FOR POWER FOR SERVICE EQUIPMENT FOR FEED-IN TARIFF PV2 SYSTEM UNDER PERMIT LISTED BELOW RATED AT 600A 480/277VPERMIT 19041-10000-16983PLAN CHECK FOR A ROOF MOUNTED 333KVA PV2 SYSTEM CONSISTING OF 4 INVERTERS(3-SE99.9K-US & 1-SE33.3K-US) WITH 1065 MODULES USING 533 OPTIMIZERS(P850)PLANS TO BE ASSIGNED TO EDWIN OR JOHN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69153	16041-20001-01987	368 N NORTON AVE	90004	4	138B189    83	5522027002	R1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM			PC Approved	01/31/2016 12:00:00 AM	ADDRESS	34.07813	-118.3169	Expedite per applicat request{{{{{{Plan check for PV roof mounted system. System size: 6.0kW with 24 modules and 1 inverter(6.0kW). Center feed with derated main breaker.}}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69154	15041-10000-10404	600 WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	REMODELING OFFICES, CORRIDORS,, BAGGAGE AREA AND FOOD PREP AREA IN TERMINAL 6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69155	14041-20000-05489	523 W 6TH ST #528	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Expired	03/28/2016 12:00:00 AM	PIN	34.04872199	-118.25441618	Install general/emergency lighting for existing building portion of 5th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69156	13041-10000-10647	600 W 7TH ST SUITE 330	90017	14	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			Verifications in Progress	07/11/2013 12:00:00 AM	ADDRESS	34.04728	-118.25685	Plan check for power. Upgrades to optional standby system in a 7-story highrise building primarily supplying data centers.  New 2500A distribution board, bus duct sections, ATSs, and CRAC units with integral ATS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69157	15041-10001-15834	1433 W 58TH ST	90062	8	108B193  1198	5003032023	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	33.98981	-118.3014	EXPEDITED RSSES PLAN CHECK PER APPLICANT REQUEST.pv1, install roof-mounted solar array on single family home, interconnect with main service panel.(10)modules: lsunpower SPR327NE-WHT-D(1) INVETER: ABBPV1-3.0-TL-OUTD-US-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69158	17041-10000-04843	6150 N CARPENTER AVE	91606	2	177B169   416	2334012037	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Issued	02/14/2017 12:00:00 AM	ADDRESS	34.1828	-118.39092	NEW ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE 8.0KW USING M250 MICRO INVERTERS, AND 32 MODULES(HYUNDAI HIS-S290RG)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69159	11041-20000-26224	5880 W SAN VICENTE BLVD	90019	10	132B177  1007	5085024021	R3-1-O	Central	Wilshire	P.I.C.O.		2163.00, 2169.00	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	11/06/2012 12:00:00 AM	ADDRESS	34.05578	-118.35988	New PV system on roof of existing commercial building, and install new service equipment, and reconnect existing interior sub pnaels to new distribution panels.lora brailo from split electric said they have nothing to do with the job and they withdrew their name from the application and permit   5/8/12 see elie maalouf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69160	19041-10000-50263	16919 W ROSCOE BLVD	91325	12	192B133   227	2205001009	M2-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM			Corrections Issued	12/06/2019 12:00:00 AM	ADDRESS	34.22139	-118.50178	T-24 PLAN CHECK FOR A TI TO A CARWASH. SCOPE INCLUDES NEW 400A UPGRADED SERVICE, NEW EQUIPMENT, RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 19,988SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69161	18041-20000-06441	2449 N MANDEVILLE CANYON ROAD	90049	11	141B133   206	4492028019	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.08114	-118.50314	PV1.  Install 9.72 kW (27 AC modules) PV system with battery backup and standby generator using Sonnen Battery System Eco 16.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69162	13041-20000-10741	121 N CLARK DR	90048	5	138B169   304	4335001019	R3-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			04/25/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	34.07588	-118.38507	New 19-unit apartment with 1200 amp service.   Full Plan Check.  METHANE ZONE. Variance will be filed to separate fire alarm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69163	12041-10000-16535	735 S FIGUEROA ST	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM			PC Approved	08/28/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	Plan check for T24 Energy/Emergency lighting for Space #122 kitchen space TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69164	19041-10000-20546	21255 W BURBANK BLVD 1ST FL	91367	3	174B105    87	2149019018	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.17432	-118.59446	PC (POWER AND ENERGY) FOR TI 3 FLOOR (ONE TENANT).  SERVICE IS 3000A, 480/277V, 3PH,4WIRE. SCOPE AREA 46,876SF.BUILDING PERMIT #:19016-10000-15847	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69165	14041-20000-31847	2125 S LOUELLA AVE	90291	11	111B149   790	4242022009	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.99945	-118.45088	PV1 SFD. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER WITH 27 MODULES. NONSTANDARD PLAN. DERATING MAIN BREAKER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69166	18041-10000-03991	603 E 115TH ST	90059	15	087A207   339	6072004027	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	33.93021	-118.26482	Plan check for Title 24 for existing lighting. add new lighting control to existing lighting. Total area: 9744 sq  ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69167	13041-20000-23614	20224 W VIA MADRIGAL	91326	12	219B113   294	2701062009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM			Corrections Issued	09/18/2013 12:00:00 AM	ADDRESS	34.29646	-118.57349	ROOF MOUNTED PV SOLAR 9.9 KW on a single family dwelling.  Plan check and permit are for PV System ONLY, NOT for Service Upgrade or De-rating of the Main Breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69168	18041-10000-24134	6748 N LANKERSHIM BLVD	91606	2	180B169    82	2320012003	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1232.05	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Issued	06/28/2018 12:00:00 AM	ADDRESS	34.19353	-118.38758	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69169	14041-20000-24806	7000 S HOOVER ST Unit #8	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #8.  System size 1.3KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69170	17041-10000-45699	14555 W VAN NUYS BLVD	91402	6	201B149   517	2647030016	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.24621	-118.44973	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69171	17041-10000-00539	5250 W SANTA MONICA BLVD #210	90029	13	144B193   736	5537020029	[T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	01/09/2017 12:00:00 AM		Issued	01/09/2017 12:00:00 AM	ADDRESS	34.09066	-118.30496	PC FOR POWER. T.I. NO CHANGE OF USE, MEDICAL OFFICE, CONNECTED LOAD < 400A.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69172	14041-10000-00239	1171 S CROCKER ST	90021	14	123A211    16	5132011240	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	01/06/2014 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.03326	-118.25169	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 815 SQFT. ALL WORK DONE ARE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69173	18041-10000-32280	2720 E 11TH ST	90023	14	120A221    94	5169009009	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/14/2018 12:00:00 AM	ADDRESS	34.02301	-118.21954	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69174	13041-10000-23053	1509 N LACHMAN LANE	90272	11	135B121    49	4420035011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.06327	-118.55012	PV1. 6.912 KWAC 240V MICROINV 2 STORY. nonSTD. ROOFMOUNT.[( 32 ) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: canadian solar CS6P-250 ]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69175	16041-10000-12188	3401 W 43RD PL	90008	10	114B185  1197	5024018001	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM			PC Approved	04/07/2016 12:00:00 AM	ADDRESS	34.00442	-118.3318	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  TOTAL SQUARE FOOTAGE 6602.  PERMIT FEES PAID UNDER APPLICATION NUMBER 16041-40000-19074.  THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69176	19041-10001-37661	611 N VIRGIL AVE	90004	13	141B197   699	5539025026	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			10/04/2019 12:00:00 AM			PC Approved	10/04/2019 12:00:00 AM	ADDRESS	34.08215	-118.28702	PLAN CHECK ONLY. T-24, ENERGY PC. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER FOR A RESTAURANT SPACE. TOTAL SQ. FT. 2445. PERMIT FEES HAVE BEEN PAID FOR UNDER MASTER APPLICATION. 19041-90000-37661______________________________________________________Relocate existing power and add 12 new cricuits. In addition we are adding an additional sub panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69177	10041-10001-06037	320 W 15TH ST	90015	14	124-5A207  85	5134015025	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/13/2010 12:00:00 AM			Corrections Issued	05/04/2010 12:00:00 AM	ADDRESS	34.03668	-118.26664	Provide new service entrance conductors to the existing 1200 ampere service from a new above ground 2000 ampere double pull section box  which also supplies the new 2000 ampere service equipment at  1513 S Grande Avenue. ((((((((((((((((((((  4-13-10 mz 2000 amps sevice split to 1200 and 2000 amps services to two different buildings 1200 amps separate application and 2000 also separate. this application fire pump and jockey sizes changed.also all feeders  increased in length this is mathane zone.))))))))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69178	18041-10000-40830	9041 N LAUREL CANYON BLVD	91352	6	195B165   118	2629032001	[T][Q]RD2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.23351	-118.40574	FIRE ALARM SYSTME ON NEW 4-STORY, 96 UNIT APARTMENT SENIOR LIVING CENTER. (1) FACP, (195) DEVICES, and (4) power supplies.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69179	13041-10005-07125	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			10/28/2015 12:00:00 AM			PC Approved	10/28/2015 12:00:00 AM	ADDRESS	34.04594	-118.25757	10/28/15Changes to an approved set, changes made to the lighting fixtures, homeruns and manufacturer changed on T-24. (((Change to approved set under field request; All changes are under delta-9 and within the description of the narative letter only.)))(((7-STORY MIXED USED BUILDING 700 UNIT APARMENT, OVER 2-LEVEL SUBTERRANEAN GARAGE :  upper 6 levels residential and retail/gym on the 1st floor. None highrise.. 5000A SERVICE;__this note : by Nabil, this methane zone.  was indicated the level changed from 5 to 2.  see plan number 12041-10000-29828))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69180	17041-20000-23830	12304 W 5TH HELENA DR	90049	11	129B141    72	4405040004	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.05325	-118.47818	"""0$ permit fees due to senate bill 1222""Plan check for solar pv system, roof-mounted on SFD.14.66kW ungrounded system.(1) 7.7kW inverter.(1) 6kW inverter.(3) 320W AC modules.(36) 360W DC modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69181	14041-10000-12798	507 N BEACHWOOD DR	90004	4	141B189  1108	5523027037	R1-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.0792	-118.32182	PV electrical generating system for existing residential buildingsystem size = 5.1 kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69182	12041-10000-02076	3712 N WRIGHTWOOD DR	91604	4	162B173  1011	2380007003	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	05/30/2012 12:00:00 AM	ADDRESS	34.13676	-118.37002	New10kw photovoltaic, rooftop, system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69183	17041-10001-30595	221 E PICO BLVD	90015	14	124-5A209 133	5145028009	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.03547	-118.25864	PLANS WERE REVISED TO INCORPORATE CHANGES THAT WOULD ALLOW THE INSTALLATION TO MEET MINIMUM ELECTRICAL CODE REQUIREMENTS PER INSPECTOR MIKE PACKARD((((((((PC FOR SERVICE UPGRADE TO 600A 120/240 3PH.SCOPE INCLUDES NEW ELECTRICAL ROOM WITH NEW SERVICE SECTION, CIRCUITS  AND LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69184	13041-10000-33107	1000 W ELYSIAN PARK AVE club	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	TI to existing visiting team clubhouse in Dodger Stadium.  Fees may need to be updated as plan check proceeds.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69185	13041-10001-29410	5835 N DONNA AVE	91356	3	174B121   777	2156012036	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			Verifications in Progress	12/03/2013 12:00:00 AM	ADDRESS	34.17647	-118.54771	Expedited RSES plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69186	15041-10000-14648	921 S CROCKER ST C 14 15 17	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  SCOPE OF WORK TO BE PERFORMED IN SUITE #C 14, 15, 17.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69187	18041-10001-24329	6401 W HOLLYWOOD BLVD	90028	13	148-5A187 139	5546006003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Approved	02/07/2019 12:00:00 AM	ADDRESS	34.10177	-118.32972	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 1. CHANGES INCLUDE ADDING NEW INVERTER FOR EMERGENCY LIGHTING AND REDUCTION OF LIGHTING FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69188	10041-10000-15263	12174 W VENTURA BLVD	91604	2	162B165   196	2369004046	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	09/24/2010 12:00:00 AM	ADDRESS	34.14312	-118.39767	Ti in an existing commercial building. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69189	11041-20000-27230	8101 W BEVERLY BLVD	90048	5	138B177   405	5514007051	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	03/02/2012 12:00:00 AM		Permit Closed	05/18/2012 12:00:00 AM	ADDRESS	34.07625	-118.36606	All new branch circuit wiring for remodeled laundry.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69190	16041-10000-18671	12714 W SEA SPRAY PL	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	33.97557	-118.41536	Installation of a new fire alarm system to an apartment building. 1 FA panel, 1 Communication panels, 75 FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69191	19041-20000-27244	11133 N ENCINO AVE pv1	91344	12	210B129   245	2711015013	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.27307	-118.51549	pv1install roof mounted pv system sized 7.9KW AC interconnecte with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69192	17041-20001-45030	22119 W VALERIO ST	91303	3	186B101   596	2023013016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.20479	-118.6088	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array on SFD.11.52kW ungrounded system. (36) 320W AC modules.Derating main breaker to 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69193	19041-10000-31162	400 WORLD WAY Space 4D	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	02/24/2020 12:00:00 AM	ADDRESS	33.94221	-118.40701	"PC ENERGY ONLY FOR TENANT IMPROVEMENT IN EXISTING  RETAIL SPACE.  ALSO, CHANGE PORTION OF RETAIL TO STORAGE (277 sqft)  ON LEVEL 3.  ""Destination LA"". area of 1137sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69194	17041-10000-46387	351 S FULLER AVE T35	90036	4	135B181   159	5509005008	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Apartment			12/27/2017 12:00:00 AM	06/20/2018 12:00:00 AM		Issued	06/20/2018 12:00:00 AM	ADDRESS	34.06852	-118.35108	Existing High-rise Building. Plan check for Core and shell power only. Service upgrade to 4,000A 120/208V and distribution. Existing emergency generator. Replace new panel inside each unit, use existing panel as J-box and extend to new panel. All load existing to remain. Project is under a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69195	16041-20000-09542	5461 N YARMOUTH AVE	91316	5	174B129   960	2162010006	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.17054	-118.52046	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.3KW .	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69196	17041-20000-01888	7252 N HATILLO AVE	91306	3	186B113   798	2115010026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2017 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.20277	-118.56522	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWa and consists of (1) inverter and (31) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69197	18041-20000-07676	12907 W FOOTHILL BLVD	91342	7	219B161   281	2514003044	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.29414	-118.4156	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is the replacement of existing fixtures with LED fixtures. Total lighting area = 11,500 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69198	14041-10001-25634	14630 W WYANDOTTE ST	91405	6	186B149   789	2218023025	R3-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Apartment			09/17/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	34.20289	-118.45203	(((Supp application for expedite fee only)))Installation of new rooftop solar photovoltaic system on multi-family affordable housing apartment building.  Total system size = 30 kWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69199	18041-10000-08642	523 W 6TH ST 2ND FLR	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO RESTROOMS LOCATED ON THE 2ND FLOOR. TOTAL SQ. FT. 1020.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69200	15041-10000-25876	2045 E VIOLET ST	90021	14	123A217    42	5166014003	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.0327	-118.23071	PC FOR ENERGY ONLY, T-24 FOR AN (E) OFFICE/ WAREHOUSE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND AND RECEPTACLES AS WELL AS OUTDOOR LIGHTING. . CONNECTED LOAD < 400AMP. TOTAL SQ. FT. 11000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69201	12041-10000-10001	1026 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM	07/06/2012 12:00:00 AM		Permit Finaled	08/13/2012 12:00:00 AM	PIN	34.02400284	-118.2895744	REMODEL MEN'S AND WOMEN'S RESTROOMS ON THE FIRST FLOOR OF THE USC LRC LOCKER ROOMSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69202	12041-10000-00859	8322 N RESEDA BLVD	91324	12	192B125   610	2786022001	C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			01/13/2012 12:00:00 AM			PC Info Complete	01/13/2012 12:00:00 AM	ADDRESS	34.22142	-118.53588	T.I. in a restaurant, plan check for title 24 only and one emergency circuit.  electric service and panels are existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69203	13041-20000-26035	1037 S NEW HAMPSHIRE AVE	90006	1	129B197   376	5078011007	R4-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			09/19/2013 12:00:00 AM	11/25/2013 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.0516	-118.29293	NEW FIRE ALARM SYSTEM FOR NEW APARTMENT. 1 FIRE ALARM PANEL, 1 ANNUNCIATOR, 5 POWER EXPANDERS, AND 266 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69204	10041-10000-08131	4501 W COLORADO BLVD	90039	4	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	07/07/2010 12:00:00 AM		Permit Finaled	03/04/2011 12:00:00 AM	ADDRESS	34.14246	-118.2705	"TI IN AN EXISTING ""B"" OCCUPANCY OF  BUILDING 4 OF ""BAXTER"".  INSTALL PANELS, CIRCUITS, LIGHTS, ETC. PLAN CHECK IS FOR POWER & ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69205	17041-20000-44265	1100 S WESTWOOD BLVD	90024	5	132B153   178	4363022004	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.0605	-118.44507	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 2,251 sq. ft.Note: Building application has been generated under 17016-20000-29495	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69206	19041-30000-17414	953 N SYCAMORE AVE 1st Floor	90038	4	144B181   641	5531015010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	Plan check for Title 24 only. Project site is an existing commercial tenant space in a high-rise building. Project scope is a tenant improvement. Total lighting area = 1,250 sq. ft.Note: Building application has been generated under 19016-10000-11719	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69207	13041-10000-36155	16509 W HARTSOOK ST	91436	5	171B137   156	2259015007	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.16369	-118.4928	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 200A MAIN IN A 3-STORY HOME. non-standard plan. SYSTEM SIZE IS 11.25 kW DC. (45)power  optimizers:Solaredge Op250-LV-AH4SM-2NA-Z   (45)Modules: Trina solar #TSM-250PA05.18(2) Transformerless inverter(s:)Solaredge #SE3800A-US and Solaredge SE6000A-US.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69208	17041-10000-33042	6461 N PENFIELD AVE	91367	3	180B113   685	2134038013	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2017 12:00:00 AM			Reviewed by Supervisor	09/27/2017 12:00:00 AM	ADDRESS	34.18827	-118.56925	PC FOR PV SYSTEM USING 65 MODULES AND 2 CENTRAL INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69209	18041-20000-07880	20656 W CHESTNUT CIR (#339)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.29356	-118.58471	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69210	19041-20000-29385	4130 W SEA VIEW LANE pv1	90065	1	151-5A221 286	5471001050	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.10859	-118.21575	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69211	18041-20000-16902	751 S BURLINGAME AVE	90049	11	126B141   668	4264007052	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			05/08/2018 12:00:00 AM			PC Info Complete	06/28/2018 12:00:00 AM	ADDRESS	34.04291	-118.48237	PV2.  Install 7.425 kW DC roof mounted grid tied PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69212	16041-10001-45829	2131 W COLORADO BLVD	90041	14	162A223    98	5671010003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	34.13937	-118.21279	Supplemental PC for chnages to approved set. Changing switchboard layout, reducing lights in bathrooms and modifying HVAC equipment loads and location. Changes clouded under delta 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69213	19041-20000-46641	541 N SWARTHMORE AVE	90272	11	126B125   783	4412018020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.03916	-118.52808	Plan check for PV roof mounted system, PV System size: 10.23KW DC with 31 PV Modules and 31 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69214	17041-20001-00640	21006 W INGOMAR ST	91304	3	189B109   888	2109018012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	ADDRESS	34.21182	-118.59111	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69215	11041-10000-17311	3975 W WILSHIRE BLVD	90010	10	132B189    26	5504027023	C4-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.06186	-118.3137	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69216	16041-20000-38625	8160 N WHITSETT AVE	91605	2	192B165   769	2308018008	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Issued	11/15/2016 12:00:00 AM	ADDRESS	34.21958	-118.40508	Plan check for PV system roof-mounted on SFD. 13.25kW ungrounded system. (41) 345W AC modules.$15.55 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69217	14041-10001-21912	9451 N MARLEY WAY	91343	7	198B149   631	2650034***	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2014 12:00:00 AM			PC Approved	10/07/2014 12:00:00 AM	ADDRESS	34.24216	-118.45777	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69218	18041-20001-45644	16838 W ADDISON ST	91436	5	171B133   670	2259005012	R1-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.16172	-118.50006	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 18.1 kWdc/15.4 kWac-CEC and consists of (55) micro-inverters, (55) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69219	11041-10000-09628	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/25/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	T.I.  CLOSING OFF AN AREA WITHIN THE LAPD FACILITY TO CREATE A NEW COMMUNITY ROOM.  ADDING NEW LIGHTS.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69220	16041-10000-02609	436 S HILL ST	90013	14	129A211    34	5149026008	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.04926	-118.25113	NEW FIRE ALARM SYSTEM TO A COMMERCIAL BUILDING. (62) FIRE ALARM DEVICES (1) FIRE ALARM PANEL AND (1) REMOTE BATTERY SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69221	19041-10000-02693	709 N HILL ST SUITE 19	90012	1	133-5A213 107	5408018021	C2-2D	Central	Central City North	Los Angeles Historic Cultural	YES	2071.02	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.06105	-118.24056	PLAN CHECK FOR POWER AND ENERGY TENANT IMPROVEMENT OF GENERAL MEDICAL OFFICE. SCOPE OF WORK INCLUDES ADDING NEW LOADS ON EXISTING PANEL, TOTAL EFFECTED AREA 896 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69222	10041-10000-25853	6301 W 3RD ST	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			PC Info Complete	01/25/2011 12:00:00 AM	ADDRESS	34.07243	-118.35963	Ti for Tommy Bahama's store. EPC is for T24, Energy, and Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69223	17041-10000-44286	1101 N LAS LOMAS AVE	90272	11	129B125    74	4420009038	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Issued	12/26/2017 12:00:00 AM	ADDRESS	34.05333	-118.5356	New rooftop solar system on SFD, 3.8kW AC. (10) modules with power optimizers, (1) SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69224	10041-10000-19241	6223 W FRANKLIN AVE	90068	4	150A189   170	5586006028	C1-1D	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	12/21/2011 12:00:00 AM	PIN	34.10543625	-118.32483465	Ti in an existing retail space. Plan check for T24 and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69225	19041-20000-13470	1300 N WILTON PL	90028	13	144B193    25	5545020008	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	06/06/2019 12:00:00 AM		Issued	06/06/2019 12:00:00 AM	ADDRESS	34.09488	-118.31348	Tenant improvement to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69226	15041-10000-22174	624 S GRAND AVE 14 FLR RR	90731	15	015B197   491	7451037001	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	33.7382	-118.28999	TI TO AN EXISTING RESTROOM IN A HIGH RISE BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANEL.  TOTAL SQUARE FOOTAGE 665.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69227	13041-10000-29918	17200 W SATICOY ST	91406	6	186B133   240	2203017043	(Q)C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM	01/06/2014 12:00:00 AM		Issued	01/06/2014 12:00:00 AM	ADDRESS	34.20827	-118.50773	PLAN CHECK FOR POWER AND ENERGY. PHASE 1 :TENANT IMPROVEMENTS AND EXPANSION OF CHASE BANK. 3 TOTAL PHASES.  PHASE 1: ADDING PANEL 1 AND 2. SERVER ROOM AND ATMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69228	17041-10000-19953	7270 W MELROSE AVE	90046	5	141B181   622	5525013004	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.08338	-118.34821	PC FOR TITLE 24 ENERGY ONLY FOR TI (N) PHOTO STUDIOINSTALLING NEW LIGHTS AND NEW RECEPTACLES. TOTAL AFFECTED AREA 2510 SQ.FTBL# 17016-10000-13241	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69229	17041-10000-17724	11300 W OLYMPIC BLVD 830	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	06/16/2017 12:00:00 AM	ADDRESS	34.03792	-118.44134	PC for T24 only for new lighting and receptacles in office areas. Total affected are is 1503 sqft.        Building permit #17016-10000-07778       Elecrical permit #17041-10000-17738	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69230	11041-10000-20308	17710 W SATICOY ST	91335	3	186B129   313	2120033032	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	09/23/2011 12:00:00 AM	ADDRESS	34.20825	-118.5189	T.I. to an existing 7-Eleven.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69231	12041-10000-30844	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			12/24/2012 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	Construct clubhouuse for right and left field within Dodger's Stadium- Power and Energy Building  #: 12010-10000-02618	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69232	16041-20000-08799	14949 W WYANDOTTE ST	91405	6	186B145   699	2221014016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.20311	-118.45917	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.5 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69233	19041-10000-43973	9400 N LURLINE AVE	91311	12	198B109   207	2748041035	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	04/08/2021 12:00:00 AM		Permit Finaled	02/21/2023 12:00:00 AM	ADDRESS	34.24106	-118.58397	Zero dollar fees due to AB 1414. PV2. NEW ROOFTOP SOLAR SYSTEM . SCOPE INCLUDES 1092 MODULES (LG ELECTRONICS LG400NW), OPTIMIZERS (P850 ), 3 INVERTER ( SE 99.9K) AND 1 INVERTER ( SE 33.3K). SYSTEM SIZE IS 333 KWac AND 436.80KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69234	11041-20000-26288	127 S SAN VICENTE BLVD #105CS	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM			PC Approved	12/09/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	added various info display on existing circuits	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69235	19041-10000-03886	1630 W SEPULVEDA BLVD	90710	15	045B193   495	7438001037	[Q]C2-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	33.81654	-118.30809	ENERGY PLAN CHECK FOR A CHANGE OF USE FOR STARBUCKS COFFEE. SCOPE INCLUDES LIGHTING, AND EQUIPMENT WITH A TOTAL AREA OF 1,682-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69236	18041-10001-49025	400 W WORLD WAY T4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			Permit Finaled	12/17/2019 12:00:00 AM	PIN	33.94094587	-118.40577128	Energy plan check supplement for a COMMERCIAL TENANT IMPROVEMENTS. Scope includes new lighting and equipment with a total area of 521-SQ FT in addation of the original scope area. Delta 1 only change	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69237	14041-20000-30312	14944 W MAGNOLIA BLVD	91403	4	171A147  1147	2263005010	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			10/31/2014 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	34.16465	-118.45906	CONSTRUCT  3 STORY APT., 18 UNITS WITH SUBTERRANEAN GARAGE. pc for power and energy. due to building submittal, plan check in accordance to 2008 NEC and building efficiency standards.Note: Variance to separate fire alarm plans filed on 10/31/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69238	11041-10000-17300	11111 W BURBANK BLVD	91601	2	174B173   943	2337029029	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.17233	-118.37285	TI TO AN EXISTING 7-ELEVEN, PLAN CHECK ONLY FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69239	15041-10000-08276	6605 N ODESSA AVE	91406	2	189B177   393	2466031026	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.19052	-118.49038	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  REPLACE EXISTING FIXTURES WITH LED LIGHTING.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69240	19041-10000-18104	5924 N FIGUEROA ST	90042	1	151-5A229  96	5492015005	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM			PC Approved	05/14/2019 12:00:00 AM	ADDRESS	34.11074	-118.19008	PC FOR T24 ENERGY ONLY FOR NEW Barber shop in existing tenant space. Total affected area 1048  sq.ftscope includes new lights and receptacles. b# 19016-10000-00414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69241	19041-20000-42139	515 S FLOWER ST STE 1020	90071	14	130-5A209 125	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 Energy only, new lighting. Total area: 1475 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69242	16041-20000-30989	4365 W PICO BLVD	90019	10	129B185  1009	5082016021	C4-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Issued	12/08/2016 12:00:00 AM	ADDRESS	34.04829	-118.33	800 AMP SERVICE UPGRADE.  PLAN CHECK FOR POWER ONLY.  LOADS TO BE FUTURE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69243	17041-10000-24511	19710 W ARUNDEL PL	91364	3	171B117   454	2175014029	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Tarzana, Woodland Hills - Warner Center		1375.04	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.16246	-118.56363	PC FOR PV SYSTEM. USING 30 MODULES. USING AC PANELS. TOTAL SIZE 10.8KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69244	18041-20000-27209	17171 W ARMSTEAD ST	91344	12	213B133   181	2607015054	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	10/09/2018 12:00:00 AM	ADDRESS	34.28288	-118.50729	PV1.  Install 10.085 kW roof mounted grid tied PV system.  (38) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69245	12041-10000-05164	1510 N SAN PABLO ST 1ST FLOOR	90033	14	135A225    62	5202004039	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM			PC Approved	03/07/2012 12:00:00 AM	ADDRESS	34.06266	-118.20215	MINOR REMODEL TO EXISTING PHARMACY  AREA( NEARBY OFFICES AND CORRIDOR ONLY)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69246	16041-10000-33683	10358 S LOU-DILLON AVE	90002	15	090A215   181	6066012055	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	05/08/2017 12:00:00 AM	ADDRESS	33.94145	-118.23473	PV1 roof mounted solar system installation to a single family home. Installing a new central inverter rated at 5.0 KWac and 18 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69247	14041-10000-21399	14402 W CALIFA ST #7	91401	4	174B149    36	2245004012	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.17739	-118.4467	Installation of roof mounted solar microinverter PV array.  This application is for one of 10 permits for the same address (labeled unit #1-10)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69248	19041-20000-51591	656 N LARCHMONT BLVD	90004	4	141B189   395	5523013001	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			12/13/2019 12:00:00 AM	02/13/2020 12:00:00 AM		Permit Finaled	05/05/2020 12:00:00 AM	ADDRESS	34.0833	-118.32347	"Plan check for Title 24 Energy only new indoor lighting in the space. Total area: 930 sq ft. B#19016-10000-38295""COMPLY WITH DEPARTMENT ORDER effective date 11/12/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69249	17041-20000-40454	11704 W BARRINGTON CT	90049	11	135B145   631	4401007018	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	04/14/2022 12:00:00 AM	ADDRESS	34.06435	-118.46944	Change of use from retail to restaurant.  Plan check for energy.  849 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69250	18041-10000-10617	1451 W KNOX ST	90501	15	057B193   125	7351037022	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	33.85422	-118.30136	Plan check for Title 24 only remove HID Fixtures and relace with new LED  Fixtures outdoor lighting. Total area: 162,175 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69251	19041-20001-13005	17052 W PAULETTE PL	91344	12	219B133   337	2608023008	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2019 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	34.29774	-118.50436	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. ADDITION OF A SOLAR METER TO PV SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69252	10041-10000-03649	13020 W PACIFIC PROMENADE # 8	90094	11	102B157   226	4211029***	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	05/24/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	33.97287	-118.42296	TENANT IMPROVEMENT IN A COMMERCIAL SPACE- NEW RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69253	11041-10000-27710	10462 N AMIGO AVE	91326	12	207B125   547	2728026018	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2011 12:00:00 AM			Reviewed by Supervisor	01/10/2012 12:00:00 AM	ADDRESS	34.26085	-118.53822	New pv for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69254	15041-20000-03861	115 N CANYON VIEW DR	90049	11	132B141   502	4405015007	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.05769	-118.48432	PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING TRANSFORMERLESS INVERTER. USING NONSTANDARD PLAN. TOTAL OF 45 MODULES. INTERCONNECT WITH 400A MSP. SYSTEM USES A COMBINER BOX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69255	11041-10000-25927	5457 N CLEON AVE	91601	4	174B173  1260	2416001013	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	01/27/2012 12:00:00 AM		Permit Finaled	05/17/2012 12:00:00 AM	ADDRESS	34.17026	-118.36873	Plan check new 27KW roof mounted photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69256	16041-10001-32076												Electrical	Electrical	1 or 2 Family Dwelling			09/09/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM				expedited plan check per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69257	18041-10003-09060	5716 W JEFFERSON BLVD	90016	10	120B173   311	5047018002	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.02582	-118.36876	CHANGES TO AN APPROVED SET OF PLANS.  ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGES INCLUDE ADDING NEW CORRIDOR EGRESS LIGHTS, AND REVISING TITLE 24 CALCULATIONS. PERMIT FOR ADDITIONAL FIXTURES AND CHANGE OF ADDRESS. B# 17016-10000-33624	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69258	15041-10001-28056	5419 W HOLLYWOOD BLVD A-E	90027	13	148-5A193 343	5544007900	C4-1VL, R3-1	Central	Hollywood	Los Feliz		1904.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	03/18/2016 12:00:00 AM	ADDRESS	34.10194	-118.30783	03/18/2016REPLAN CHECK TO STAMP LOST STAMPED SET. (((ALTERATIONS IN A T-MOBILE RETAIL STOREPLAN CHK IS FOR TITLE 24))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69259	18041-20000-40536	17389 W RAINBOW RIDGE CIR	91344	12	216B129   323	2601052005	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.28603	-118.51328	Plan check for a PV1 roof-mounted PV system. System size is 11.88 kWdc/10.6 kWac and consists of (33) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69260	19041-20000-15919	1801 S MESA ST	90731	15	012B201   776	7456029027		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	33.72772	-118.28594	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM FOR NEW SFD. SYSTEM SIZE IS 3.02KW DC/2.88KW AC. SCOPE OF WORK INCLUDES (9) SUNPOWER PV SYSTEMS WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69261	19041-10002-32886	758 S ALVARADO ST	90057	1	132A203   235	5141019008	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM			PC Approved	10/21/2019 12:00:00 AM	ADDRESS	34.05497	-118.27758	Changes to an approved set of plans. All changes ared clouded under delta 2. Changes include revising feeder size and conduit to panel to reflect as built. Note: Permit is paid under PCIS#19041-20000-32886	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69262	15041-20000-41746	338 S HIGHLAND AVE	90020	4	135B185   183	5507003007	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	PIN	34.06772806	-118.33811993	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 6.75KWac/7.695KWdc.(27)MODULES-SOLAR WORLD SW285 MONO(27)MICROINVERTERS-ENPHASE M250-60-2LL-S22-IG(1) 100A SUBPANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69263	16041-10000-09301	4947 E HUNTINGTON DR NORTH	90032	14	144A233   287	5306014051	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2012.00	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Info Complete	03/16/2016 12:00:00 AM	ADDRESS	34.08756	-118.17568	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAUARANT (McDonald's). Scope includes new lighting. Total affected area is 2794 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69264	19041-20000-47907	2143 S VICTORIA AVE	90016	10	123B185   220	5061002028	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.03609	-118.33473	PV1.  Install 4.00 kW roof mounted grid tied PV system.  (10) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69265	18041-20000-07346	4108 N KRAFT AVE	91604	2	162B169   204	2368020023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Issued	03/06/2018 12:00:00 AM	ADDRESS	34.14276	-118.37992	PV1.  Install roof mounted PV system sized 13.6kW interconnected with MSP.  (3) tesla power walls.$0 permit fee per State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69266	19041-10000-37380	13406 W SATICOY ST	91605	2	186B157   187	2303024024	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	ADDRESS	34.20853	-118.42489	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69267	17041-20000-28125	14927 W NAVARRE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29442	-118.45616	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69268	19041-20000-15155	5808 W SUNSET BLVD LEVEL 11	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.09782	-118.31646	T24 ONLY PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL LEVEL 11. LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 460SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69269	15041-10000-39578	12665 W VILLAGE LANE	90094	11	102B161  1257	4211034064	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	09/28/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	33.97786	-118.41484	"ONE  ILLUMINATED LEDs MONUMENT WALL SIGN [3'-6"" X 20'X 7' HIGH] WITHIN PLANTERplan chk is for title 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69270	16041-10000-09341	520 N AMALFI DR	90272	11	123B129   368	4408024006	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM			PC Approved	09/07/2016 12:00:00 AM	ADDRESS	34.03413	-118.51398	(New) 2-Story SFD.  1200A MS, total connected load > 800A. PC for Power only.ATTENTION: PLAN CHECKER TO VERIFY THE SECOND SERVICE, ADDITIONAL FEES MAY BE REQUIRED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69271	11041-20000-14418	5518-5522 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			07/12/2011 12:00:00 AM			Corrections Issued	07/12/2011 12:00:00 AM	ADDRESS	34.06209	-118.34908	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING TENANT SPACE INTO SHOW ROOMS AND RETAIL STORE SPACES. WEST WING FIRST FLOOR TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69272	13041-20000-21131	8223 N TUNNEY AVE	91335	3	192B117   883	2105017012	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Expired	09/02/2015 12:00:00 AM	ADDRESS	34.21915	-118.55702	New rooftop PV System for an existing single family dwelling.  System uses Enphase Microinveters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69273	16041-10000-05160	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/12/2016 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR POWER . MEDIUM VOLTAGE. COMMERCIAL BUILDING. ADDITION OF  4 VFD FOR 4 CHILLERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69274	11041-20000-00534	2850 W RIVERSIDE DR	90039	4	151-5A207  63	5438025011	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	03/22/2011 12:00:00 AM		Permit Finaled	11/28/2011 12:00:00 AM	ADDRESS	34.10998	-118.26339	New roof mounted 57.96 KW photovoltaic system for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69275	14041-20000-34474	2254 S WELLESLEY AVE	90064	11	123B149   927	4259030013	R1-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	02/24/2015 12:00:00 AM	ADDRESS	34.03002	-118.45362	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(16) CANADIAN SOLAR CS6P-250P MODULES(1) SOLAREDGE SE3800 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69276	16041-20000-11774	2844 E 2ND ST	90033	14	126A225   188	5180022900	OS-1XL	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM			PC Approved	04/05/2016 12:00:00 AM	ADDRESS	34.03905	-118.20448	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING. EVERGREEN REC CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69277	16041-10000-06074	1549 S BEVERLY DR 1-14	90035	5	129B165  1236	4306014104	[Q]R3-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			02/22/2016 12:00:00 AM			PC Info Complete	03/29/2017 12:00:00 AM	ADDRESS	34.05098	-118.39564	PC FOR POWER AND ENERGY. NEW 4-STORY 14 UNITS APARTMENT BUILDING WITH 2 LEVELS GARAGE. 1600A SERVICE. TOTAL AREA 23558 INDOOR LIGTING PLUS 2754 OUTDOOR LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69278	19041-10000-21598	7240 N TOPANGA CANYON BLVD	91303	3	186B101   980	2111022021	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Issued	06/07/2019 12:00:00 AM	ADDRESS	34.2023	-118.6057	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69279	14041-10000-28126	2006 S LA CIENEGA BLVD	90034	10	126B173   817	5066002002	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	01/12/2015 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.04001	-118.37684	PLAN CHECK FOR ENERGY ONLY FOR EXISTING OFFICE BUILDING. SCOPE OF WORK 1800SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69280	16041-10002-38982	1250 S WESTMORELAND AVE	90006	1	129B197   979	5076018023	R4-1XL	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM	ADDRESS	34.0479	-118.2889	PLAN CHECK ONLY FOR DELTAS 10 AND 12 CHANGES TO APPROVED SET. CHANGING RESIDENTIAL DISTRIBUTION BOARD RATING TO 1200A AND ADDRESSING ATS2 FOR ELEVATORS  AS LEGALLY REQUIRED STANDBY SYSTEMS. NO OTHER CHANGES APPROVED. Previous Scope: THIS IS PLAN CHECK ONLY FOR REVISION TO APPROVED PLAN, ALL CHANGES NOTED AS DELTA 4. SYSTEM SIZE NOW AT 2500A. PERMIT IS COVERED UNDER MASTER #16041-10000-38982<<<<PLAN CHECK FOR POWER AND TITLE 24.  NEW 7-STORY 93-UNIT SENIOR AFFORDABLE BUILDING.  SYSTEM INCLUDES NEW 3,000 AMP 208/120 VOLT SERVICE, EMERGENCY GENERATOR, AND FIRE PUMP.  TOTAL COMMON AREA = 52,040 SQ. FT.>>>>>(REF B# 16010-10000-05028)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69281	13041-10000-28470	1801 W 6TH ST	90057	1	133-5A205 346	5154025001	C2-1	Central	Westlake	Westlake South		2089.04	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM	02/26/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.05807	-118.27115	TITLE 24 ENERGY PLAN CHECK ONLY. PREVIOUSLY BANK AND RETAIL TO OFFICES.  4026 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69282	18041-10000-48230	1041-1043 S WESTWOOD BLVD	90024	5	132B149    47	4363018015	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	07/10/2019 12:00:00 AM		Issued	07/10/2019 12:00:00 AM	ADDRESS	34.06172	-118.44559	FIRST TIME TENANT. EXISTING CORE & SHELL.  INSTALL NEW PANELS & LIGHTS. PLAN CHECK FOR POWER & ENERGY. 3120 SQR FT.BUILDING PERMIT: 18016-10000-39696	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69283	10041-10000-16687	5960 W SUNSET BLVD	90028	13	147A191    86	5545014001	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	04/11/2014 12:00:00 AM	ADDRESS	34.09787	-118.31961	New 10 story mixed use trade school building. Plan check for power and energy. (T24 fee is not included)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69284	15041-20000-14765	12550 W OTSEGO ST	91607	2	171B161   804	2357007002	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.16303	-118.40689	Installation of new roof mounted solar PV array.  Total system size = 9.8 kWac.  Two central inverters are used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69285	16041-20001-16553	1663 S LA CIENEGA BLVD	90035	5	129B173  1220	4303028034	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.04727	-118.37639	05/18/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms. NOTE: PERIMIT PAID UNDER PCIS#16041-10000-05885*****Previous Work Description*****PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT FOR RESTAURANT. 1545 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69286	14041-20000-30857	7880 N VAN NUYS BLVD	91402	6	189B149   638	2212028014	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.21541	-118.4462	Complete gut and rebuild. new service, new equipment, new lighting. This is a vanilla shell. 800A service. PC for power and energy. TI will be submitted by tenant at another time. zoned for retail use.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69287	18041-20003-48286	403 S HIGHLAND AVE	90036	4	135B185   254	5507013001	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.06668	-118.33875	$0 Permit fee due to CA SB 1222 AND AB1414SUPPLEMENTAL FOR CHANGE TO APPROVED SET, ADDITION OF 1 PV MODULE, AND CHANGE TO DC SYSTEM SIZE FROM 13.68 KW DC TO 14.04 KW DC. PROJECT NOW READS TO BE A 39 PV MODULE ROOFTOP PV SYSTEM.CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69288	19041-20000-24001	528 N WILCOX AVE	90004	4	141B185  1058	5523037021	RE9-1-HPOZ	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.07975	-118.33067	Plan check for PV roof mounted system, PV system size: 10.73KW DC, 10.0KW AC with 29 PV Modules and inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69289	16041-20000-17606	515 S FIGUEROA ST #1250	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check Title 24 only for existing high-rise office building T.I. Total area: 3,558 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69290	19041-20000-34792	12940 W ADDISON ST	91423	4	168B161  1198	2358023024	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	09/14/2019 12:00:00 AM	ADDRESS	34.16107	-118.41537	PV1.  Addition of (12) modules to (E) 15.3 kW roof mounted grid tied PV system for a total new system size of 19.5 kW.  Downsizing of main to 175A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69291	11041-20000-21792	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM			PC Approved	10/12/2011 12:00:00 AM	ADDRESS	34.32381	-118.49103	energy plan check warehouse	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69292	19041-20000-27252	466 N LA BREA AVE	90036	5	141B181  1202	5525029024	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	08/10/2020 12:00:00 AM	ADDRESS	34.08007	-118.34385	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69293	19041-10001-03264	10445 N GLENOAKS BLVD	91331	7	204B165    23	2537002005	M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.26013	-118.39759	CHANGES TO AN APPROVED SET TO REFLECT INSTALLED AND PER INSPECTOR RQUEST. CHANGES TO THE NUMBER OF DEVICES AND ADDITION OF 1 POWER SUPPLY TO SUPPLY THE RELAYS. Original Scope: New FA system for a (N) warehouse building,  (1) FACP, (2) Power Supply, (160) devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69294	10041-20000-11008	3616 S TROUSDALE PKWY #B55	90089	9	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM			PC Info Complete	06/10/2010 12:00:00 AM	ADDRESS	34.01983	-118.28534	PLAN CHECK ONLY. THIS PLAN IS REPLACED BY PLAN CHECK #10041-20000-16943. Plan check T-24 Energy (general/emergency) lighting renovation in the basement of USC AHJ Spatial Sciences Rm #B55.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69295	10041-20000-10705	11111 W SANTA MONICA BLVD s1040	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles			2673.00	Electrical	Electrical	Commercial			06/07/2010 12:00:00 AM	06/07/2010 12:00:00 AM		Permit Finaled	07/16/2010 12:00:00 AM	ADDRESS	34.04771	-118.44481	s1040 office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69296	14041-10000-32945	10521 W SEABURY LANE	90077	5	151-5A151 438	4380006007	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Expired	12/20/2016 12:00:00 AM	ADDRESS	34.1098	-118.44844	PV1 standard plan, 4.2kw roof mounted system including 4.2kw inverter and (22) modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69297	15041-20001-33301	11917 N RICASOLI WAY LOT 9	91326	12	216B109   121	2701078***	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.28909	-118.58488	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. USING TOTAL OF 24 MODULES. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69298	11041-10000-12751	1 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/28/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of 1elevator unit in ADMIN at LAX. East Bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69299	18041-10000-41998	8800 N WOODMAN AVE	91331	6	195B153   655	2640017015	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.23012	-118.4363	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69300	17041-10000-16220	5011 S WESTERN AVE	90062	8	111B193  1222	5016037002	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	33.99759	-118.30908	PC for energy only. Outdoor Title-24. Removing HID fixtures and adding new LED lights. Area: 8175 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69301	13041-10003-06157	3000 S HOOVER ST	90007	9	121-5A201 144	5123005031	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM			PC Approved	04/08/2015 12:00:00 AM	ADDRESS	34.02712	-118.28376	Revision to permitted set of plans. moving panel EM2c removed from main swiched board M and moved to panel EM2A. All loads are existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69302	14041-10002-07978	3150 W WILSHIRE BLVD #118	90010	10	132B197    39	5077010006	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM			PC Approved	08/04/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	"TENANT IMPROVEMENT FOR ""NEW"" ""JIMMY JOHN'S"" RESTAURANT INTO NEW HIGH RISE WITH RESTAURANT USES;((((((((((((((   7-5-14  changes made to approved set , title 24,  M,Z  )))))))))))))))  8-4-14  deleting pendent lites)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69303	16041-10000-16070	380 WORLD WAY Space-34A	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/06/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Expired	08/23/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	Energy plan check for a retail T.I  located inside the Tom Bradly airport, terminal-4, Space-34A. Total area 250-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69304	11041-20000-07812	307 N LA BREA AVE	90036	5	138B181   364	5525033032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM			Corrections Issued	05/26/2011 12:00:00 AM	ADDRESS	34.07647	-118.34435	New car wash building with new 800 amp service.  Plan check for power and energy. Site in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69305	19041-20000-36872	18319 W SAN JOSE ST	91326	12	207B125   538	2731005016	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.26102	-118.53258	PV1. INSTALL 11.34 KW DC ROOF MOUNTED SOLAR SYSTEM WITH (36) MODULES AND OPTIMIZERS. SCOPE OF WORK INCLUDES (1) INVERTER (SE11400H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69306	12041-10000-23114	2555 E OLYMPIC BLVD	90023	14	121-5A219  42	5170011***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Public Safety Only			09/27/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.02566	-118.2231	New fire alarm system for a server room. (Room 400)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69307	17041-10000-19121	802 E E ST	90810	15	030B209  1214	7424015061	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			06/07/2017 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	PIN	33.77558988	-118.25229481	PC for power and energy for addition of recycling building to existing manufacturing plant. PC for new 1600 A  480/277V service in methane zone. Total area of 42000 sqft. Building #16010-40000-04106.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69308	17041-10000-10665	7663 W WENTWORTH ST	91042	7	207B197   107	2552025016	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.26702	-118.29999	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 11.34 kWdc     2  ABB VPI-4.2-OUTD-S inverters @ 4.2 kWac each.    36 LG 315N1C-Z4 modules @ 315 watts each.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69309	18041-10001-20349	1607 E PLEASANT AVE # 1	90033	14	129A221    80	5174024026	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			Verifications in Progress	07/17/2018 12:00:00 AM	ADDRESS	34.04838	-118.22052	1 OF 2*****EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69310	15041-10000-31718	317 S BROADWAY C2/B3	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.05069	-118.24861	PC FOR ENERGY ONLY.  2 STORY BUILDING , ONE BASEMENT. FASTFOOD STORE.TOTAL AREA  385 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69311	15041-10001-08838	10710 W CHALON ROAD	90077	5	141B149   147	4362003036	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2016 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Expired	09/22/2023 12:00:00 AM	ADDRESS	34.08283	-118.44927	PC for power only. Changes to an approved set of plans. All changes are clouded under delta E1. Changes include going from a 600A service to an 800A service, new subpanels, new load equipment, and revisions to floor plans. (((Plan check for power for a new single family home. Project scope includes the installation of a new 600 amp service, (2) 600-amp rated main switchboard, (9) subpanels and associated loads, (1) 50 kWac generator, and (1) 5HP elevator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69312	15041-20001-34972	8950 N GLENOAKS BLVD	91352	6	195B173   149	2408005031	(Q)M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.2319	-118.36828	EXPEDITE PER APPLICANT REQUEST.(((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 68.85 KWac. (300) MODULES- QCELL.PRO BFR-G3 255-265(300) OPTIMIZERS-SOLAREDGE P300(6)INVERTERS-SOLAREDGE SE11400A-US(1) 225A LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69313	19041-30000-26088	2013 S MORAY AVE	90732	15	012B193  1040	7562011006	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	33.72638	-118.31288	PV1 , Rroof-mounted PV system using central inverters.. PV system consist of two types of modules. System 1 consist of (21) modules, (21) optimizers,  (1)  7.6KWAC central inverter and  (1) LG battery back up. DC coupled system. System 2 consist of (80) roof shingle modules and (1) 3.8KWAC central  inverter with rapid shutdown. Total system size is 11.4KWAC/11.23KWDC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69314	13041-10001-32867	13350 N LOS OLIVOS ST	91342	7	225B145   499	2501003038	(Q)RS-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.31448	-118.46885	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69315	13041-10000-35235	3500 S SAN PEDRO ST PV2	90011	9	117A207   235	5121010008	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	04/09/2014 12:00:00 AM		Issued	04/09/2014 12:00:00 AM	ADDRESS	34.01445	-118.26565	PV2, ROOF-MOUNTED SOLAR PV INSTALLATION IN (E) WAREHOUSE, INTERCONNECTING TO (E) 240/120, 400A 1PH 3W MAIN SWITCH GEAR. SYSTEM SIZE IS 23.7W kW DC. 20.39kW AC WITH 8 TOTAL STRINGS. SYSTEM IS TRANSFORMERED, WITH THE FOLLOWING EQUIPMENT TO BE USED:(3) INVERTERS: SMA SB 8000US, SB 6000US, SB 7000US(1) 200A SOLAR SUBPANEL(93) MODULES: EAT PHONO SOLAR, SW255MONONOTE: PLANS NON-EXPEDITED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69316	10041-10001-18021	810-812 N CROFT AVE	90069		141B173   153	5529003019	[Q]R3-1		Hollywood	Mid City West			Electrical	Electrical	Apartment			09/26/2011 12:00:00 AM			PC Approved	09/27/2011 12:00:00 AM	ADDRESS	34.08572	-118.37409	Modification to previously approved applicaiton.  Added note to show conduit/conductor type and size from service to main panel. <<<<NEW 4-STORY 6 UNITS APARTMENT W/ BASEMENT GARAGE>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69317	09041-10005-11227	2600 W WILSHIRE BLVD	90057	1	133-5A201 122	5141008900	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM			PC Approved	08/01/2012 12:00:00 AM	ADDRESS	34.06041	-118.28167	REVISED PLANS TO SHOW AREAS ON 3RD,4TH, AND 5TH FLOORS THAT WERE NOT DEVELOPED.PLAN CHECK IS FOR TITLE 24 AND POWER FOR THOSE AREASPlan check power and energy for installation of new panels, circuits, emergency generator, and emergency equipment.  Existing service, transformer, and  distribution boards.  5 story building with 3 level of subterranean parking.  Variance to seperate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69318	17041-10000-05076	4196 S MARLTON AVE	90008	8	114B181   312	5032021024	[Q]RD5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.00862	-118.34247	Plan check for Title 24 only in existing space remove outdoor HID lighting fixtures and replace with new LED lighting fixtures. Total area: 17,125  sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69319	11041-10001-00601	732 E 10TH ST Unit 104	90021	9	124-5A211 354			Central				2260.00	Electrical	Electrical	Commercial			01/20/2011 12:00:00 AM	01/31/2011 12:00:00 AM		Permit Finaled	02/09/2011 12:00:00 AM	ADDRESS	34.03504	-118.25099	Plan check for electrical and T-24 for space 104. first time occupant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69320	13041-10000-02006	1888 CENTURY PARK EAST	90067										Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			PC Approved	05/02/2013 12:00:00 AM				HIGH RISE BUILDING 20 FLOORS - FIRST REPUBLIC BANK.  TI FOR CAFETERIA LOCATED ON 3RD FLOOR.  T24 OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69321	18041-20001-35481	8812 W YATES ST	91040	7	204B189   544	2546006029	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1034.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM			PC Approved	09/23/2018 12:00:00 AM	ADDRESS	34.25647	-118.32526	Expedite per applicant requestPlan check for PV roof mounted system and Energy Storage System, PV System size: 15.05KW DC, 13.68KW AC with 43 PV Modules and 43 Microinverters and 1 Tesla Battery PowerWall 2.0 13.5kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69322	16041-20001-43878	16536 W GILMORE ST	91406	6	180B137   679	2231010060	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2016 12:00:00 AM			PC Approved	12/17/2016 12:00:00 AM	ADDRESS	34.18737	-118.49376	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69323	10041-10002-01068	3435 W WILSHIRE BLVD 152	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			02/09/2010 12:00:00 AM			PC Approved	02/09/2010 12:00:00 AM	ADDRESS	34.06194	-118.29866	Changes to previously approved plans.  Change in lighting with Delta-3 as shown on plans.  Plan check for energy only.***Changes to previously approved plans.  Change includes addition of new water heater.  P/C is for Power only :: T. I work in office area of unit 152. This P/C is only title 24 energy only.***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69324	16041-20000-38368	11135 W MAGNOLIA AVE #170	91601	2	171B173  1385	2350018082	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	ADDRESS	34.16512	-118.37384	"PLANCHECK FOR T24 ENERGY. T. I. FOR  ""CREAM"" ICE CREAM STORE.  SINGLE STORY COMMERCIAL SPACE.  BUILDING PERMIT # 16016-20000-25940"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69325	15041-20001-03418	12130 W MILLENNIUM 1ST FLR	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.98008	-118.40646	Changes to an approved set of plans. Changes include the removal of (1) panel and the transferring the loads of that panel onto an existing panel.*****Previous Work Description*****TI TO AN EXISTING COMMERCIAL HIGH RISE OFFICE BUILDING.  ADDING NEW LIGHTING, NEW CONTROLS AND NEW PANELS.  NEWLY CONNECTED  LOAD <400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4043.  SCOPE OF WORK TO BE PERFORMED IN THE 1ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69326	18041-10000-09592	17744 W CHATSWORTH ST	91344	12	207B129   450	2733006026	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	ADDRESS	34.26466	-118.52129	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69327	17041-20001-32629	13018 W BURTON ST	91605	2	192B161   245	2304003018	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.22053	-118.41724	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD. Interconnecting with a 400A MSP.10kW ungrounded system. (36) 330W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69328	18041-20000-03871	1307 S OCEAN FRONT WALK	90291	11	108A143   412	4226006003	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	33.98828	-118.47474	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 919 sq. ft.Note: Building application has been generated under 17016-20000-28554	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69329	18041-10000-01817	136 S VIRGIL AVE 1-143	90004	13	138A201   203	5501017045	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			01/17/2018 12:00:00 AM			PC Info Complete	01/17/2018 12:00:00 AM	ADDRESS	34.0724	-118.28659	Plan check for T24 only to revise 1st floor fitness and party room. Install new lights, receptacles, (3) new panels with load < 200A (B#16014-30000-02262)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69330	10041-20001-07080	11811 W OLYMPIC BLVD	90025	11	123B149   409	4259023015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM			PC Approved	05/26/2010 12:00:00 AM	PIN	34.03353292	-118.45117088	PLAN CHECK ONLY. PLAN CHECK TO APPROVED PLANS. REVISION TO LIGHTING FIXTURES TYPES. INTERIOR TENANT IMPROVEMENT SCIENCE AND LIBRARY. This plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69331	15041-10000-16344	11533 W DONA PEPITA PL	91604	2	156B169   190	2381024012	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM			PC Info Complete	07/16/2015 12:00:00 AM	ADDRESS	34.12634	-118.38613	PV1, INSTALL 10.080 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(36) MODULES: SOLARWORLD PLUS SW 280 MONO BLACK(1) INVERTER: FRONIUS IG PLUS A 7.5-1 UNI 240 V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69332	14041-10000-33493	6015 W 3RD ST	90036	5	135B181    19	5512013030	C1-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.07018	-118.35165	TI to (E) single-story building tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69333	19041-10001-21190	3916 W SUNSET BLVD	90029	13	145-5A203 391	5427007003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.09192	-118.28012	CHANGES TO APPROVED T-24 PLANS. <<<Energy plan check for a retail T.I. Scope includes new lighting and equipment with a total lighting area of 1458-SQ FT.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69334	12041-10000-19620	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	2951.01	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	33.77884	-118.29327	Plan check for new 4000V motor (350HP), 480V transformer, panel, and branch cicuits. Installation in hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69335	18041-20000-22593	10650 N DE SOTO AVE	91311	12	207B109   345	2706011001	(T)(Q)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	06/01/2020 12:00:00 AM	ADDRESS	34.26388	-118.58835	Plan check for power and energy new West Valley Chrstina Church 600A Service over 100 occupant load  with associated load. Total area; 7288 sq ft B#16010-20000-06270	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69336	10041-20000-06840	505 S BONNIE BRAE ST	90057	1	133-5A205 270	5154026002	[T][Q]R4-1	Central	Westlake		YES	2089.03	Electrical	Electrical	Apartment			04/14/2010 12:00:00 AM			PC Approved	04/14/2010 12:00:00 AM	ADDRESS	34.05924	-118.27229	add 75 lights and 75 outlets to approved plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69337	17041-20000-21621	21045 W OSBORNE ST	91304	3	195B105    41	2779048009	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.23322	-118.59228	Plan check for energy only. TI to manufacturing building (warehouse, offices, restrooms). New lighting (incl. emergency). 14,583sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69338	16041-10000-40378	521 E DOLORES ST	90744	15	036B209   225	7422025020	R1-1XL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/17/2016 12:00:00 AM	ADDRESS	33.79444	-118.25737	PV1 roof mounted solar system installation to a single family home. Installing a central inverter rated at 3.8KW bieng fed from 12 solar modules in series from one string.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69339	13041-20002-33556	1020 E VERNON AVE	90291	11	111B145   239	4243027012	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.00319	-118.46243	EXPEDITE FEES ONLY     <<<New rooftop PV System for an existin sfr.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69340	15041-10000-03691	1819 N KINGSLEY DR	90027	13	150A195   231	5544010012	R3-1	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Apartment			02/06/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.10407	-118.30367	Over the counter plan check for fire alarm. Install new FACP to monitor. exisiting fire sprinkler system. New  smoke detectors by the elevator..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69341	17041-10000-09580	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	10/29/2017 12:00:00 AM	ADDRESS	34.03982	-118.24098	NEW FIRE ALARM SYSTEM FOR AN EXISTING APARTMENT BUILDING. SCOPE INCLUDES 112 FA DEVICES AND 5 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69342	12041-20000-23248	219 N LARCHMONT BLVD	90004	4	138B189   604	5515018015	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.07525	-118.32384	Replace existing flourescent lights and  install 13 pieces of 4 foot lighting track and one ceiling light to the same circuit.  T-24 lighting plan check for remodeled retail space.  See department order 469015.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69343	15041-10000-22732	8500 W BEVERLY BLVD UNIT 712	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI TO AN EXISING COMMERCIAL BUILDING. ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69344	13041-20000-19417	6320 W SUNSET BLVD	90028	13	147A187   143	5546015029	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/23/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.09783	-118.32747	New panels and loads to an existing 2-story office building.  Full Plan check for Power and Energy is requested by the applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69345	17041-10000-03419	12853 W VICTORY BLVD	91606	2	180B161  1038	2325032008	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/06/2017 12:00:00 AM	ADDRESS	34.18683	-118.41321	PC for outdoor title 24. Removing HID fixtures and raplaing them with LED ones. Area: 15,425 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69346	17041-10000-41171	11120 W CHANDLER BLVD Bldg 2	91601	2	171B173   167	2350015042	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Public Safety Only			11/14/2017 12:00:00 AM	01/29/2018 12:00:00 AM		Issued	01/29/2018 12:00:00 AM	ADDRESS	34.168	-118.37317	NEW FIRE WARNING SYSTEM FOR NEW APARTMENT BUILDING- BLDG 2. Scope includes 1-fire alrm panel, 12-control panels, and 401-devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69347	10041-20000-18341	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM			PC Approved	09/16/2010 12:00:00 AM	ADDRESS	33.96577	-118.42406	revision to approved plans change routing feeder of 5 kv line change elevator location and title 24 in library area plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69348	14041-20000-21937	3330 N CAHUENGA BLVD WEST # 502	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			08/13/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.13099	-118.35061	Title 24 plan check only on a commerical building. Total working area is 4081 SQ feet.  Plan check is based on building permit submited before July 1st.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69349	16041-20000-15650	19821 W NORDHOFF PL	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.23686	-118.56502	PLANCHECK FOR T24 ONLY. REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69350	15041-10002-03435	200 WORLD WAY #233	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/14/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	((7/14/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE REDUCING LIGHTING LOAD AND REVISING ENERGY CALCS.  CHANGES NOTED DELTA 4 ON THE PLANS.  THIS IS PLAN CHECK  ONLY.Change toa an approved set by modifying the lighting floor plan and adding starters for equipment units.(((Plan check for power and title 24.  Total area = 550 sq. ft.Installation of new electrical distribution equipment (3 panels and 1 transformer in series) in airport space.  First time tenant.  New lighting and recepticles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69351	14041-10000-09463	20700 W NORTHRIDGE ROAD	91311	12	210B113    53	2707002001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM	04/09/2014 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.27146	-118.57213	NEW FIRE ALARM MONITORING FOR SINGLE FAMILY DWELLING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69352	19041-10000-28947	2911 W EXPOSITION PL Units3	90018	10	117B185  1312	5044011026	CM-1-SP, RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02047	-118.32807	Plan check for a PV2 3.00kw AC / 2.6KW DC  roofmounted system with (1) inverter and  (8) modules interconnecting through the main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69353	13041-10000-26113	9635 N CEDROS AVE	91402	6	201B149   603	2650018013	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	34.24528	-118.45309	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 8.255KW DC IN A 1-STORY HOME ON CENTRAL INVERTER STANDARD PLAN. (33) MODULES: HANWHA #HSL60P6-PB-4(1)INVERTER: FRONIUS V 7.5	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69354	13041-10000-10775	515 S FIGUEROA ST 13th Floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM			PC Approved	04/25/2013 12:00:00 AM	ADDRESS	34.05199	-118.25764	T24 FOR EXISTING OFFICE SPACE 13TH FLOOR. CONFERENCE ROOM, BOARD ROOM, BATHROOM, AND PARTIAL OPEN OFFICE. 4,210 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69355	15041-20000-14004	20801 W VENTURA BLVD	91364	3	171B109    62	2166033045	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM			Reviewed by Supervisor	05/19/2015 12:00:00 AM	ADDRESS	34.16663	-118.58589	Plan check for power and Title-24.  Total area = 61 sq. ft.  Addition of patient exam room adjacent to pharmacy center in existing retail space (Target).  Renovation of sales floor with new recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69356	19041-10000-35117	164 W JEFFERSON BLVD	90007	9	118-5A203 101	5122031006	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.01934	-118.27453	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXUTRES - T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69357	19041-20000-47004	19656 W FALCON RIDGE LANE	91326	12	217-5A117 183	2701022028	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.28965	-118.56213	Plan check for PV roof mounted system, PV system size: 9.715KW DC, 7.856KW AC with 29 PV modules and 29 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69358	17041-10000-35453	10957 S CENTRAL AVE	90059	15	088-5A209 260	6071020001	MR1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	03/20/2023 12:00:00 AM	ADDRESS	33.93558	-118.2544	PC FOR TITLE FIRE DAMAGE REPAIR TO (E) COMMUNITY CENTER. FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 7283 SQ.FT SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRUCUITS ANN LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69359	18041-10001-48230	1041-1043 S WESTWOOD BLVD	90024	5	132B149    47	4363018015	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM			PC Approved	03/28/2019 12:00:00 AM	ADDRESS	34.06172	-118.44559	Delta 1 changes to an approved set. Changes to the restroom configaration on second floor to comply with ADA requirements. Change receptacle location and lighting configeration. All changes are signed by the engineer. Miner changes to fixture number on T-24 forms. Original Scope: ((FIRST TIME TENANT. EXISTING CORE & SHELL.  INSTALL NEW PANELS & LIGHTS. PLAN CHECK FOR POWER & ENERGY. 3120 SQR FT.BUILDING PERMIT: 18016-10000-39696))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69360	14041-20000-15087	2753 W WAVERLY DR 1-63	90039	4	151-5A207 233	5438025012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Apartment			06/06/2014 12:00:00 AM	09/23/2014 12:00:00 AM		Permit Finaled	02/13/2017 12:00:00 AM	ADDRESS	34.10855	-118.26334	New fire alarm system for new townhome 63 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69361	11041-20000-08828	17320 W LAHEY ST	91344	12	210B129   271	2711010012	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	07/06/2011 12:00:00 AM	ADDRESS	34.27308	-118.51194	Plan check for 12.69 KW Photovoltaic system roof mounted on single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69362	15041-20000-31544	10220 N RESEDA BLVD	91324	12	204B125   175	2731018018	(Q)C2-1VL, C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.25657	-118.53585	TI to existing commercial building (nail salon). Plan check for energy only. Adding new lighting including emergency. Total sqft. 1732.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69363	15041-20000-26912	9548 N CRANFORD AVE	91331	7	198B157    27	2626001016	RS-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	01/26/2016 12:00:00 AM	ADDRESS	34.2433	-118.41961	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter, (14) modules, and (14) power optimizers. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69364	14041-20000-11621	16201 W SAN FERNANDO MISSION BLVD	91344	12	210B141   409	2681011039	C2-1VL, P-1VL, QC2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			05/01/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.27207	-118.48535	PLANCHECK FOR POWER AND ENERGY. CONVERTING MARKET TO  DMV offices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69365	11041-20000-06767	727 W 7TH ST 1st floor	90017	9	129A209   265	5144029***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	08/19/2011 12:00:00 AM	ADDRESS	34.04861	-118.25837	T.I. to existing high rise building.  Install general/emergency lighting in the bar.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69366	17041-20000-14870	6041 W CADILLAC AVE	90034	10	126B173   862	5066003021	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Permit Finaled	09/09/2020 12:00:00 AM	ADDRESS	34.03806	-118.37594	Plan check for installation of solar pv carports installed on rooftop of existing parking garage structure.425kW ungrounded system. (1672) 310W pv modules. Building permit application #17016-10000-11539.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69367	11041-10000-13096	700 S BROADWAY # 216	90014	14	127-5A211  64	5144015053	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Approved	06/29/2011 12:00:00 AM	ADDRESS	34.04492	-118.25338	T24 and emergency lighting plan check for subdivided retail space where an existing retail space is divided  to create a  new exit corridor for the building.  Existing 11041-10000-13096.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69368	15041-10001-05835	3012 S BAGLEY AVE	90034	5	123B165   485	4311022003	R1-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.03427	-118.39456	PV1.  Install 4.59 kW roof-mounted PV system.  (E) 4.62 kW roof-mounted system interconnected with new system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69369	11041-20000-16202	1204 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			08/08/2011 12:00:00 AM	08/18/2011 12:00:00 AM		Permit Finaled	10/11/2011 12:00:00 AM	ADDRESS	34.02523	-118.29185	"New 3.23 Kw Pv solar equipment ( max 3 psf inhibiting superimposed concentrated loads and max 18"" above existing roof) system for an apartment Bldg."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69370	13041-20000-36116	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/27/2013 12:00:00 AM			PC Info Complete	03/18/2014 12:00:00 AM	PIN	34.0586034	-118.41904766	Install a new power center rated 400A.  Plan check for energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69371	15041-30001-12233	218 S MAIN ST	90291	11	111B141   507	4286003021	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	33.99733	-118.47869	05/03/2016 Changes to an approved set of plans. Changes have been made to the lighting fixture schedule. All changes have been reflected onto the lighting floor plan and the Title 24 Compliance Forms. The engineer on record has changed. *****Previous Work Description*****Change of use from retail to restaurant and associated TI work.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69372	19041-10001-05881	10828 N BALBOA BLVD	91344	12	207B133   174	2683027005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Approved	03/14/2019 12:00:00 AM	ADDRESS	34.26686	-118.50205	DELTA 1 CHANGE TO AN APPROVED SET FOR PV1. CHANGE INCLUDS RELLOCATING MAIN PANEL, LOAD CENTER , DISCONNECT SWITCH AND JUNCTION BOXES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69373	13041-10001-27141	17544 W LANARK ST	91325	12	189B129   143	2201005009	R1-1	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.21786	-118.51582	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 4 kW. TRANSFORMERLESS INVERTER. TWO STORY.(16) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-3.6-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69374	14041-20001-20567	11351 N DRONFIELD AVE	91331	7	210B165     6	2532009009	A2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.27673	-118.4036	Fee for expedite only.*****New carport roof mounted PV system with system 68.75KW for new school.Note: The other PV system (57.25KW) is building roof mounted system is under 14041-20000-20563  Both PV systems are on the same plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69375	19041-20000-07675	7957 N SANGAMON AVE	91352	2	189B181   194	2403013006	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.21599	-118.34739	Installation of 13.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69376	15041-10002-43517	8717 N DARBY AVE	91325	12	195B125   809	2769025011	M1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.2292	-118.53371	"CHANGES TO PERMITTED SET OF PLANS: LIGHTING PLANS AND TITLE 24 COMPLIANCE FORMS UPDATED; FEEDER CIRCUITS BREAKERS ARE FULL RATED AT 65KAIC; SRVICE CONDUCTORS ARE 2 SETS OF 300MCM; FOR PANELS ""A ""  AND  ""DC"", MAIN CB AND BRANCH CIRCUIT CBs ARE SERUIES RATED FOR 22KAIC; REOCATE RECEPTACLES ;NEW CICUITS ADDEDALL CHANGES ARE CLOUDED"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69377	17041-20000-06676	105 S FAIRFAX AVE	90036	5	138B177   597	5511025032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Apartment			03/01/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.07398	-118.36162	New mixed use 45-unit three story apartment building.  New 1600A 120/208V 3ph-4w service.  Plan check for power and energy.  Methane zone.  Building permit filed under 15010-10000-03183.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69378	14041-20000-20076	2240 N CHELAN PL	90046	4	153B181   339	5572012006	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/30/2014 12:00:00 AM		Permit Finaled	11/21/2014 12:00:00 AM	PIN	34.1123886	-118.34632425	pv1install roof mounted pv system sized 5.76kw interconnected with msp.(24) solarworld sw280 modules(24) enphase m250 miroinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69379	10041-20000-07121	1985 E ZONAL AVE #112	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	05/28/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check T-24 Energy mandatory measures at USC lecture Room 112 at Pharmaceutical Science Building. No new wattage being added.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69380	16041-10000-34337	515 S FLOWER ST 3550	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR SUITE 3550. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3501 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69381	15041-10000-17012	8635 W 3RD ST STE 1150W	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.07373	-118.38073	TI-24 TO AN (E) OFFICE BUILDING. ADDING NEW LED LIGHTING TO TWO OFFICES. TOTAL SQ. FT. 160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69382	16041-20000-23497	3620 S VERMONT AVE	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.02213	-118.29133	Plan check for power and energy T.I. Adding 600A 480V motor equipment and associted load in existing USC laboratory Kaprielian Hall [KAP]. Rooms: #B39, #B44 plus Pit. Total indoor area: 319 sq ft. and Total outdoor area: 705 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69383	16041-10000-39501	757 S FLOWER ST	90017	14	129A209   122	5144010009	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.04752	-118.2601	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69384	15041-10000-05680	11975 W BLUFF CREEK DR	90094	11	105B165   921	4211011064	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.98224	-118.40247	(N) fire alarm system for building 3 core and shell.  (N) FACP and (16) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69385	19041-10000-29035	21110 W OXNARD ST	91367	3	177B105    76	2149002023	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Closed	02/16/2022 12:00:00 AM	ADDRESS	34.17903	-118.59355	Design build: Power plan check for a new temp' power construction. Scope includes (1) 800 Amp service, (1) transformer, (1) construction trailer, and (6) spider boxes.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69386	11041-20000-27682	4424 N WINNETKA AVE	91364	3	165B113    69	2174026005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2011 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	02/23/2012 12:00:00 AM	ADDRESS	34.15142	-118.57139	New 6.9 KW roof mounted PV system for a single family residence.  Applicant is using the standard plan for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69387	15041-20000-05323	16996 W STRAWBERRY DR	91436	5	165B133   538	2292008026	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.14475	-118.50276	Installation of new roof mounted solar PV microinverter array.  Total system size = 9.9 kWac. 3 branch circuits with 36 modules total.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69388	16041-30000-07582	8915 S SEPULVEDA BLVD	90045	11	096B165  1047	4122036030	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Issued	03/10/2016 12:00:00 AM	ADDRESS	33.95548	-118.3965	Plan check for Title 24 only for T.I. office space. Total area:4608 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69389	18041-10000-46036	555 W 5TH ST 44th FLR	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR T-24 ONLY, INTERIRO RESTROOM REMODEL ON 44TH FLOOR. 508SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69390	17041-20001-25273	515 S FIGUEROA ST ste 750	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	08/03/2017 Changes to an approved set of plans. Changes have been made to the lighting control layout.*****Previous Work Description*****ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69391	17041-10000-27854	1601 N VINE ST	90028	13	148-5A187 301	5546009154	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.09996	-118.32693	PC FOR FA TI  IN COMMERCIAL BLDG. TOTAL DEVICE COUNT 194 WITH 11 NEW BOOSTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69392	19041-10000-41314	1011 S FIGUEROA ST B 115	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.04476	-118.26452	remodeling of existing retaurant- new circuits and lightingplan check is for title 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69393	14041-10001-21444	9074 N VAN NUYS BLVD	91402	6	198B149   582	2639007024	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.23513	-118.45006	Supp app for full plan check for medical office T.I.  Expedite fees listed on submital 2 + extra plan check hour at supervisor request.Master application for title 24 plan check at counter. Area = 1230 sq. ft. T.I. to existing medical office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69394	12041-10000-14642	3525 W 8TH ST	90005	10	132B193   572	5093011013	(Q)C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM	06/25/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.05782	-118.30714	ADDITION TO EXISTING RETAIL BUILDING. NEW ENCLOSED SPACE TO HOUSE ELEVATOR AND ESCALATORS; LIGHTING AND POER TO THE NEW SPACE.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69395	12041-20000-22652	725 S FIGUEROA ST 24TH FLOOR	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM			PC Approved	09/24/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for energy and emergency lighting. Commercial high rise. 24th Floor, Suite 2400.19585 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69396	12041-10003-17970	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	REVISED PLNS TO SHOW CHANGES MADE FOR A TEMPORARY KITCHEN AREA AND RELOCATING OF KITCHEN EQUIPMENT INTO A NEARBY AREA; REVISED LIGHTING IN  KITCHEN STORAGE AREA.TI FO RTHE FIRST CLASS LOUNGE AND JOINT LOUNGE AT THE EXISTING AND NEW 5TH FLOOR OF THE TOM BRABLY TERMINAL  AT  LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69397	14041-20000-20867	11611 W SAN VICENTE BLVD	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	ADDRESS	34.0541	-118.46261	Plan check for energy only on 7th floor elevator lobby/corridor inside a commercial building. PC based on 2008 standard due to early submital of building permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69398	17041-20000-32901	18163 W SHERMAN WAY	91335	3	186B125   894	2119028015	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Issued	01/11/2018 12:00:00 AM	ADDRESS	34.20135	-118.5295	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to laundry mat/tenant improvement. Work includes a new 600-amp service and a total lighting area of 4,194 sq. ft.Note: Building application has been generated under 17016-20000-24644	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69399	19041-10000-46919	146 N ORANGE DR	90036	5	138B181   629	5513005008	R2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Issued	11/14/2019 12:00:00 AM	ADDRESS	34.07497	-118.34174	NEW ROOF MOUNTED 3.3KW PV SYSTEM WITH 10 @ (330W) PV PANELS AND OPTIMIZER AND ONE 3KW CENTERAL INVERTER ON A DUPLEX BULDING .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69400	18041-10000-24980	13156 N WHISTLER AVE	91344	12	222B133    32	2602002015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.03	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.30875	-118.50476	New 7.3KW (DC) roof mounted PV system with 24 PV modules on a single family home.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69401	19041-10000-06915	17281 W SUNSET BLVD	90272	11	126B117   293	4416002900	[Q]RD5-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.04222	-118.55419	Remove outdoor hid fixtures and replace with new led fixtures - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69402	10041-10000-23685	819 S HOLT AVE 1-6	90035	5	135B173  1010	4333024007	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.00	Electrical	Electrical	Apartment			11/29/2010 12:00:00 AM	04/21/2011 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.06235	-118.37856	NEW 4 STORIES 6 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69403	13041-20000-22217	261 S FIGUEROA ST STE 200	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			08/15/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.05546	-118.25446	Plan check for energy only. Office spaces. Suite 200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69404	14041-10001-06984	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	34.20696	-118.3417	(((T24 FOR SOUTH SIDE OF THE DOMATORY AREA. PERMIT HAS ALREADY BEEN PULLED ON THE ORIGINAL THIS IS A PLAN CHECK ONLY)))Installing 9, 10 watt down lightsinstalling 4, 20 amp receptacles 2 occupancy light sensors 1 disconnect for wheel chair lift	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69405	18041-20000-44551	5161 N AMESTOY AVE	91316	5	171B133   350	2258008024	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	12/26/2018 12:00:00 AM	ADDRESS	34.16454	-118.50558	Plan check for 13.32KW PV solar rooftop w/37 ACM modules. connected to 400A main panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69406	14041-20000-14267	13041 N HERRICK AVE	91342	7	222B149   296	2506023009	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.30689	-118.45561	Roof mounted PV system with Enphase microinverter, Model M215-60-2LL.  PV system size 5.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69407	15041-20000-42579	5753 N CRANER AVE	91601	2	174B173   387	2415004017	R1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.17538	-118.36935	Plan check for a PV1 roof-mounted PV system. System size is 8.2 kWac and consists of (1) inverter, (42) modules, and (1) combiner box. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69408	19041-10000-22496	767 S ALAMEDA ST ROW-STE 250	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	Tenant improvement in private office and meeting roomplan check is for title 24	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
69409	15041-20001-09516	12696 N WOODCOCK AVE	91342	7	222B149  1095	2507001017	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM			PC Approved	05/04/2015 12:00:00 AM	ADDRESS	34.30114	-118.4488	Change to approved set of plan. Change to the layout of the modules per inspector's request. ************Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Microinverter system with two branch circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69410	17041-10000-04272	560 W 182ND ST	90248	15	063B201   128	7339007025	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	33.86969	-118.28368	Plan check for Title 24 only replace indoor HID fixtures with new LED fixtures in existing space. Total area: 4,000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69411	18041-20000-23004	10842 N MARKLEIN AVE	91345	7	207B145    78	2664015006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Issued	06/20/2018 12:00:00 AM	ADDRESS	34.26758	-118.47011	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69412	19041-20000-07931	639 N NORTH BROADWAY	90012	1	133-5A215 162	5408016002	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Apartment			03/05/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Issued	04/24/2019 12:00:00 AM	ADDRESS	34.05972	-118.2398	Plan check for a PV2 roof-mounted PV system. System size is 340.91 kWdc/311.51 kWac-CEC and consists of (6) inverters, (2) load centers, and (934) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69413	12041-10000-17653	19710 W VENTURA BLVD	91364	3	174B117   363	2164011029	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01, 1394.00	Electrical	Electrical	Commercial			07/27/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.17231	-118.56286	New lighting and receptacles to an existing office building.  Low rise.  Load is less than 400A per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69414	14041-20001-03472	14971 W FOOTHILL BLVD	91342	7	228B145    89	2502002021	RA-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.32265	-118.45958	(((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 18KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. 3 SOLAR EDGE USING POWER OPTIMIZERS. SYSTEM TAPPING AHEAD OF THE MAIN. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69415	15041-30000-44043	6952 N POMELO DR	91307	12	183B089   416	2028030005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.19697	-118.65033	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69416	19041-20001-21643	1709 W 35TH ST	90018	8	120B193   792	5041005041	C2-2D-O-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	06/25/2019 12:00:00 AM	ADDRESS	34.02482	-118.30928	PC FOR NEW ROOF PV SYSTEM ON (E) COMMERCIAL BLDG. SYSTEM SIZE IS 38.5KW DC/35.3KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69417	14041-10000-26487	6815-6821 S VICTORIA AVE	90043	8	102B185   577	4006023004	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM			Reviewed by Supervisor	10/17/2014 12:00:00 AM	ADDRESS	33.97641	-118.33248	Plan check for service upgrade and outdoor T24 in a TI commercial building.note to plan checker, title 24 page is missing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69418	17041-10000-27897	5611 N FIGUEROA ST 1-5	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Closed	03/21/2018 12:00:00 AM	ADDRESS	34.10937	-118.19392	PC FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD <400ATOTAL AFFECTED AREA 2288 SQ.FT (INDOOR + OUTDOOR)SCOPE INCLUDES NEW PANELS CIRCUITS LIGHTS AND EQUIPMENT. B#16016-10000-30146	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69419	15041-20000-19186	12435 W OLYMPIC BLVD	90025	11	123B145   336	4259019005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	PIN	34.03188711	-118.45923154	Title 24 plan check only.  Total area = 13,023 sq. ft.  T.I. to existing commercial lowrise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69420	14041-20000-27964	7032 N OWENSMOUTH AVE	91303	3	183B105   541	2138008006	P-1VL-RIO, [Q]C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	10/09/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.19831	-118.60139	TI TO AN EXISTING COMMERCIAL TWO STORY BUILDING.  ADDING LIGHTING FIXTURES TO EXISTING POWER EQUIPMENT.  PLAN CHECK FOR ENERGY 3398 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69421	16041-30000-17653	5325 E BALTIMORE ST	90042	1	154-5A227 220	5478009041	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.11754	-118.20032	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (13) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69422	19041-20000-45709	11557-11565 W ERWIN ST	91606	2	177B169   303	2335030014	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1241.04	Electrical	Electrical	Apartment			11/06/2019 12:00:00 AM	05/12/2021 12:00:00 AM		Permit Finaled	02/07/2024 12:00:00 AM	ADDRESS	34.18316	-118.38409	NEW 1000 AMP SINGLE PHASE SERVICE NEW PANELS, EQUIPMENTS AND LIGHTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69423	16041-30001-18170	644 W 2ND ST	90731	15	018B197  1295	7451009018	R2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM			PC Approved	06/08/2016 12:00:00 AM	ADDRESS	33.7425	-118.29102	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (13) modules and (1) inverter. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69424	15041-20000-40370	7631 W BECKETT ST	91042	7	204A197   283	2558035021	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.25381	-118.299	PV1.  Install 5.16 kW roof-mounted, utility-interactive PV system.  (21) Silvantis F-Series 270W w/ (1) SolarEdge SE5000A-US transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69425	18041-10000-21634	2706 E MEDIA CENTER DR	90065	1	150B213  3657	5442032005	[Q]M2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM			PC Info Complete	06/21/2018 12:00:00 AM	ADDRESS	34.10771	-118.24215	PC FOR TITLE 24 ENERGY ONLY FOR INTERIOR RENOVATION OF EXISTING OFFICE SPACE: CONVERT PORTION OF (E) STORAGE TO OFFICE.SCOPE INCULDES NEW PANEL, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 2920 SQ.FT B#18016-10000-13810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69426	14041-20000-05208	12801 W NORTH SEAGLASS CIR	90094	11	102B161  1224	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	33.97509	-118.41784	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING 9 MODULES AND TRANSFORMERLESS INVERTER. NONSTANDARD PLAN, roof-mounted.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69427	11041-10000-03352	15250 W VENTURA BLVD	91403	5	168B145   974	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.02	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	04/06/2011 12:00:00 AM	ADDRESS	34.15351	-118.46549	TENANT IMPROVEMENT TO EXISTING 12-STORY OFFICE BUILDING.  TITLE 24 ONLY PLAN CHECK OVER THE COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69428	15041-20000-15725	1857 N HILLHURST AVE	90027	4	150B197   941	5590016026	C4-1D	Central	Hollywood	Los Feliz		1891.01	Electrical	Electrical	Commercial			05/21/2015 12:00:00 AM			PC Approved	05/21/2015 12:00:00 AM	ADDRESS	34.10474	-118.28758	Plan check title 24 only for outdoor lighting. Total area: 461 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69429	19041-20001-18920	10509 W CAMARILLO ST pv1	91602	4	168B177   481	2420004016	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM			PC Approved	06/11/2019 12:00:00 AM	ADDRESS	34.15781	-118.35961	Addition of AC disconnect for inverter.$0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.  (((pv1install roof mounted pv system sized 10KW AC interconnected with msp.(2) tesla powerwalls ESS at 5KW AC each)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69430	18041-30000-22825	13155 W MINDANAO WAY D5	90292	11	105B153    86	4212004004	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Approved	06/19/2018 12:00:00 AM	ADDRESS	33.98509	-118.43769	Plan check for T24 only, permit has been issued under express permit# 18041-20000-16561.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69431	13041-20000-15692	2836 W SUNSET BLVD	90026	13	141A205    65	5426020007	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1958.04	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	05/11/2015 12:00:00 AM	ADDRESS	34.08223	-118.27276	FULL PLAN CHECK FOR POWER AND ENERGY. CHANGE OF USE FORM RESTAURANT TO MEDICAL. ACCUPUNCTURE. TOTAL AREA 1527 SQFT.  NOT STATE LICENSED, NOT CHECKED FOR OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69432	12041-10002-25781	814 N TOULON DR	90272	11	126B133    72	4408014022	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.04408	-118.50973	][]CHANGES MADE TO APPROVED SET OF PLANS; PER DWP , CHARGER STATION AND  BATTERY ARE OMITTED. INVERTER SMA 4000-US IS NEW; FUSE SIZE FOR DC SIZED AT 10AMPS. THE LETTER FROM SMA CONFORMING THAT THE FRONIUS 7.5 AND SMA 4000-US WILL WORK TOGETHER WHEN SYSTEM IS ATTACHED. CUSTOMER UNDERSTANDS TO CONFORM WITH WET SIGNATURE REQUIREMENT, REMOVING ALL NON-RELATED CLOUDINGS, AND PRINT ALL HANDWRITTEN ITEMS . AT LAST, NEEDS FIRE APPROVAL STAMP BEFORE FINAL APPROVAL IS GRANTED. 1/30/14 NOTE: ROOF-TOP INSTALLATION][][],Photovoltaic system with battery charger system for single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69433	19041-10000-39005	6118 W 6TH ST	90048	5	135B177   416	5510026039	R2-1-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	02/21/2020 12:00:00 AM	ADDRESS	34.06486	-118.36209	[E-plan]  Changes to approved set, all changes are clouded under delta b. Scope of work includes addition of one  LG chem battery, and reducing the number of solar PV module. Orginal permit is under 19041-10000-30233	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69434	13041-10000-08899	3768 N VINELAND AVE	91604	4	162B173   871	2378005011	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.13767	-118.36785	PV1  SINGLE STORY HOUSE. [INVERTER: solaredge se6000a-us] [MODULE: trina solar tsm-240pa05}]. Nonstandard PLAN ROOF MOUNTED with 24 solaredge optimizers  #OP250-LV-MC4SM-2NA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69435	13041-10000-01675	3932 N FILION ST	90065	13	156A217    92	5459014007	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	34.12302	-118.23204	PV1 ROOF MOUNTED MICROINVETER SOLAR INSTALLATION ON STANDARD PLAN. SINGLE STORY HOUSE. SYSTEM SIZE IS 2.16 KW. 10 MODULES IN A SINGLE CIRCUIT. [MODULES: REC # REC245PE |||| INVERTERS: ENPHASE  # M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69436	15041-10002-16824	4570 W COLORADO BLVD	90039	13	162B205   118	5593018015	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.14078	-118.27277	2/23/2016Changes to approved set of plans, PC for energy only. Revision of lighting and power. Note changes under delta 5. (((( 12-15-15T-24, Changes to an approved set of plans, changes include the revision of lighting and receptacle lay out. Note changes on delta 4.  (((TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS  TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQURE FOOTAGE 16,130.)))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69437	19041-10000-35355	801 E E ST	90744	15	030B209   741	7424014021	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/06/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	07/31/2020 12:00:00 AM	ADDRESS	33.77626	-118.25281	PC FOR NEW FA SYSTEM 1 FACP AND 53 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69438	16041-20003-40989	1060 W EXPOSITION BLVD ste 101-104	90037	8	117B197   508	5037015030	(T)(Q)C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM				supplemetal permit for building 1077 W 38TH ST to subfeed building 1060 W EXPOSITION BLVD, SUITE NUMBERS 101, 102, 103, AND 104.This permit is also to include suite numbers 101 and 102 at address 1077 W 38TH ST.  ((((Plan check for power and energy. New 5 story building - 4-story 140 unit apartment (10 typ. units) over ground level parking garage and office space. (2) 2500A services and (1) 1000A service. T24 - indoor: 80,830sqft ; outdoor: 39,286sqft. NEW 5 STORY  PARTMENT BUILDING : 4 STORY TYPE V-A ,  140 UNITS ABOVE TYPE 1-A GROUND LEVEL PARKIN GARAGE & OFFICE ( 138 LOW INCOME RENTAL  UNITS & 2 MANAGER UNITS)   . THE PROJECT DOES NOT PROVIDE HOUSING ON BEHALF OF ANY PUBLIC INSTITUION BUT IS PARTIALLY PUBLICLY FUNDED AND SUBJECT TO UFAS REQUIREMENTS.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69439	12041-10000-15786	2300 N LIVE OAK DR WEST	90068	4	153B193   331	5587005029	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Issued	10/22/2012 12:00:00 AM	ADDRESS	34.11254	-118.31096	Additional rooftop photovoltaic panels and inverter added to an existing photovoltaic system for a commercial building.  System runs partially underground, Not in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69440	12041-10000-17808	6521 W LA MIRADA AVE	90038	4	144B185  1298	5533002075	R3-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2012 12:00:00 AM			Corrections Issued	03/06/2013 12:00:00 AM	ADDRESS	34.09352	-118.33181	New 3kw rooftop photovoltaic system for a new single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69441	10041-20000-21828	9679 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	01/06/2011 12:00:00 AM	ADDRESS	34.24653	-118.5363	T.I. for hair salon.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69442	13041-20000-08928	812 W 165TH PL	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	33.88061	-118.28977	Plan check for alteration of a church into a charter school. Environmental Charter School.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69443	13041-10000-29789	11100 W SANTA MONICA BLVD	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/24/2013 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.04726	-118.44465	Installation of lights to outdoor canopy serving patio area adjacent to high-rise office building.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69444	14041-10001-11671	5633 N RIVERTON AVE	91601	2	174B177   438	2415008016	R2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	34.1731	-118.36606	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 5.0 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER: POWER-ONE # AURORA PVI-4.2-OUTD-S-US-Z-A(20) MODULES: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69445	18041-10000-46349	1618 E 99TH ST	90002	15	091-5A213  18	6048016021	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	33.9466	-118.24553	Plan check for an add on 2.88kDC / 1.92KW AC PV1 roof-mounted solar system, in additon to an existing PV system. Scope include (8) modues and IQ-7 microinverters interconnecting through a subpanel.Note. Portion of the permit fee is paid under 18041-90000-44470.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69446	12041-10000-04953	9040 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	04/09/2012 12:00:00 AM	ADDRESS	34.23439	-118.55336	T.I. to an existing retail space, less than 400A of load.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69447	18041-20002-10510	10828 W VIA VERONA	90077	5	147B145   114	4377037017	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Expired	09/22/2023 12:00:00 AM	ADDRESS	34.09911	-118.4588	1/10/2019changes to an approved set of plans.  changes to include load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69448	17041-10000-27543	11631 W VICTORY BLVD	91606	2	180B169  1019	2335012019	C1-1VL, RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	03/20/2019 12:00:00 AM		Permit Finaled	07/20/2022 12:00:00 AM	ADDRESS	34.18685	-118.38564	OFFICE TI. BUILDING ADDITION OF BASEMENT AND SECOND FLOOR. PC FOR POWER AND ENERGY. THIS IS CORE AND SHELL SCOPE OF WORK.B#16014-10000-00298	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69449	15041-10001-01530	1656 1/2 W 36TH PL	90018	8	120B193  1423	5041022014	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.02178	-118.30766	Expedited per applicant request.install roof mounted solar array, interconnect with main panel. system size: 7.65kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69450	14041-10002-34546	1011 S SERRANO AVE 1-104	90006	10	129B193   356	5080014012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			09/27/2019 12:00:00 AM			PC Approved	09/27/2019 12:00:00 AM	ADDRESS	34.0522	-118.3065	"DELTA ""2"" changes to approved plans. changing the layout of Lobby.Plan Check Only. Permit: 14041-10000-34546<<<Plan check power and energy for new 104 units appartment>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69451	14041-20000-07215	20300 W TAU PL	91311	12	207B113   245	2707017015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			Reviewed by Supervisor	03/25/2014 12:00:00 AM	ADDRESS	34.2609	-118.57574	NEW SYSTEM DESIGN WAS SUBMITTEDDISREGARD THIS APPLICATIONRoof mounted PV system with size 10KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69452	13041-10000-35875	947 S TIVERTON AVE 10F,11F	90024	5	135B153   610	4363019009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			12/24/2013 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.06246	-118.44303	pc for power and energy. assisted-living TI EXIST APT UNITS ON ENITRE 8TH AND 9TH FLOORS.4TH AND 5TH FLOOR PC # 13041-10000-356426TH AND 7TH FLOOR PC # 13041-10000-358628TH AND 9TH FLOOR PC # 13041-10000-35872ADDITION OF GENERATORS AND PANELS  PC # 13041-10000-35626	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69453	12041-10000-13714	4800 N LAUREL CANYON BLVD	91607	2	168B165   505	2355010023	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM	10/03/2012 12:00:00 AM		Permit Finaled	10/16/2012 12:00:00 AM	ADDRESS	34.15798	-118.39628	PLAN CHECK T24 ENERGY INTERIOR REMODEL OF EXISTING STARBUCKS. EXISTING EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69454	17041-10000-07959	3785 W WILSHIRE BLVD 104D/E	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			03/13/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.06187	-118.30858	T-24, PC FOR ENERGY ONLY.CHANGE OF USE FROM RETAIL TO OFFICE (1670 SF) ON GROUND FLOOR OF EXISTING HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1515 SQ. FT.  b#17016-10000-02836	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69455	16041-10001-16933	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	PC FOR CHANGES UNDER DELTA 11. FOR  REVISIONS TO REFLECT CHANGES ON FIELD. SCOPE INCLUDES UPDATES TO PANEL SCHEDULES . ADDITION AND REMOVAL OF OUTLETSADDED LOADS AND OTHER MINOR CHANGES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69456	16041-10000-36084	3716 W BOYCE AVE	90039	13	156A207   331	5435012027	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	01/10/2017 12:00:00 AM	ADDRESS	34.12095	-118.26114	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. REPLACE HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR. TOTAL AFFECTED AREA IS 2500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69457	13041-10001-17687	4519 W COCKERHAM DR	90027	4	153B197   173	5588023037	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.11466	-118.29075	changes to approved plans: adding shunt trip to shut off power to main building (panel DPA).Power only for single family dwelling. PV installation is not part of scope. Panel A, B, C, C1, D and ACP are new.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69458	16041-30000-38693	1200 W WILSHIRE BLVD 5th Floor	90017	1	130-5A207  69	5143019022	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	05/09/2017 12:00:00 AM	ADDRESS	34.05294	-118.26512	Plan check for Title 24 only in existing space office T.I. in 5th Floor. Total area 15951 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69459	17041-10000-26145	2231 S WESTERN AVE	90018	10	123B193   238	5058009041	C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.01	Electrical	Electrical	Apartment			08/23/2017 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	06/22/2020 12:00:00 AM	ADDRESS	34.03519	-118.30929	PC for power and energy for 60 unit, 6 story, and one basement level apartment building. PC for new 1200A 277/480 service, on site fire pump, emergency generator, new equipment and new distribution panels located in methane zone. This project is an adaptive reuse project converting from hospital to apartment building (17016-10000-18981). Total area 87751 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69460	15041-20002-05340	6316 N TOPANGA CANYON BLVD SUITE 1110	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	07-21-2015 Change to approve set of plan minor changes to circuit clouded in delta 1. lPLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. XOC TEQUILA GRILL. WESTFIELD TOPANGA MALL. SUITE 1110	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69461	19041-20000-38082	15207 W SUNSET BLVD UNIT C	90272	11	129B129   809	4423016073	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			09/23/2019 12:00:00 AM			PC Info Complete	10/04/2019 12:00:00 AM	ADDRESS	34.04647	-118.52446	Plan check for Title 24 Energy  for Tenant Improvement for physical therapy office on second floor. Total area: 872 sq ft. B#19016*-20000-30243	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69462	16041-10001-43139	5440 N TOPANGA CANYON BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.17004	-118.60552	SUPPLEMENTAL PC FOR T24 FOR CHANGED LIGHTING AND RECEPTACLES. CHANGES CLOUDED UNDER DELTA  2 AND 3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69463	13041-20000-31222	10736 W HORTENSE ST	91602	2	168B177   847	2421030016	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			11/07/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.15456	-118.36502	New 4-unit apartment building, new 400 amp service.   PLAN CHECK ONLY for Energy in the Common Areas.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69464	19041-10000-18467	8639 S LINCOLN BLVD	90045	11	096B157   667	4119026036	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	06/19/2020 12:00:00 AM	ADDRESS	33.95887	-118.41869	FULL PC FOR ENERGY AND PWR(PER CUSTOMER REQUEST). SCOPE INCLUDES RENOVATION OF EXISTING HOTEL LOBBY INTERIOR. AREA OF SCOPE IS 2,569SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69465	17041-30000-33524	2049 S CENTURY PARK EAST 19th Floor-lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only in existing highrise building elevator lobby in 19th Floor. Total area: 295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69466	15041-10000-27350	7447 N RUTHERFORD HILL DR	91304	12	186B089   333	2027045028	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	PIN	34.20677858	-118.65014539	pv1 install new 13475 kw dc solar array for a single family home.(49) modules: rec solar recc275tp(1) inverter: solaredge se 11400a-us-	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69467	14041-10000-33736	3721 W SENECA AVE	90039	13	156B209   140	5435001018	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.12223	-118.25915	PV1.  Install 5.355 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.FEE AMOUNT REFLECT ON SENATE 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69468	16041-10000-37033	23413 W VICTORY BLVD	91307	12	180B093   822	2036011011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.18665	-118.63707	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(18)MODULES-HANWHA Q.CELL PLUS-G4 280(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69469	12041-20000-15463	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	Changes from previously approved plans (12041-10000-11744).  Changes include lighting luminaire and building address, Suite O-10.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69470	17041-20001-05885	7992 N HOLLYWOOD WAY	91352	2	189B181   205	2403024007	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.21587	-118.34521	Expedite fee.  PV1.  Install 12.41 kW roof mounted grid tied PV system.  (40) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69471	11041-10002-15811	700 S SANTA FE AVE	90021	14	124-5A217 273	5166002011	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			12/20/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	34.03435	-118.22981	UPGRADE SERVICE TO 600A AND MADE CHANGES TO LIGHTING SYSTEM; PERMIT HAVE BEEN OBTAINED FOR THE CIRCUITSthis is additional permit for additional ckts and equipment. title 24 approved under 11041-20000-15811 TAKE-OUT BAKERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69472	11041-10000-16281	415 N MISSION ROAD UNIT A	90033	14	130-5A219  46	5410006008	[Q]M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.20	Electrical	Electrical	Commercial			08/03/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.05361	-118.22654	T.I. FOR INDUSTRIAL STORAGE  BUILDING.   PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69473	14041-10001-20422	9603 N VAN NUYS BLVD	91402	6	201B149   642	2650021***	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM			PC Approved	10/09/2014 12:00:00 AM	ADDRESS	34.24455	-118.45043	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV2, ROOF-MOUNTED SOLAR ARRAY ON A COMERCIAL BUILDING, INTERCONNECT WITH MAIN SERVICE PANEL.(12) KYOCERA KD255GX-LFB3(1) POWER-ONE INVERTER: AURORA PVI-3.0-OUTD-S-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69474	17041-10000-22792	11601 W WILSHIRE BLVD FLR 22ND	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR HALLWAY AND LOBBY  TI IN A HIGH RISE (22nd FLOOR) FOR TITLE 24  ENERGY ONLY. TOTAL AFFECTED AREA  1200 SQ.FTINSTALLING NEW LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69475	19041-10000-34976	3840 S CRENSHAW BLVD #200	90008	10	117B185   751	5033003016	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Issued	10/28/2019 12:00:00 AM	ADDRESS	34.01618	-118.33474	PLAN CHEK FOR ENERGY ONLY  - Scope includes new lighting and equipment with a total lighting area of 4,672-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69476	10041-20000-23703	2020 S CENTRAL AVE	90011	11, 9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2677.00	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.02302	-118.25162	PLAN CHECK POWER AND ENERGY FOR  MEDICAL OFFICE. (FIRST TIME TENANT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69477	17041-20000-16361	9034 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.23415	-118.55337	ti to an existing restaurant.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69478	12041-10003-31058	15154 W WEDDINGTON ST PV1	91411	4	172-5A147 168	2250003010	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.16715	-118.46373	[[[changes made to approved plans. removed 4 modules for a total of 40 modules - 6/7/2013]]]((((CHANGES MADE TO ORIGINAL PLANS. ADDED 9 MORE MODULES AND IT IS A TRANSFORMERLESS SYSTEM))))))INSTALL ROOF MOUNTED SOLAR, INTERCONNECT MAIN SERVICE PANEL.(8.4KW) Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69479	15041-20000-37855	189 S THE GROVE DR G-60	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (VINCE STORE ). SCOPE INCLUDES NEW LIGHTING, TWO NEW PANELS, AND ONE TRANSFORMER. TOTAL AREA IS 2439 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69480	14041-20000-15005	20750 W SHERMAN WAY	91306	3	183B109    80	2137020037	(T)RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Apartment			06/05/2014 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.20086	-118.5852	NEW 3-STORY,  95 UNIT ELDER CARE FACILITY: 94 SENIOR UNITS (32 Independent units & 62 Assisted Living units),  ONE MANAGERS UNIT and ONGRADE PARKING LOT per ZA2012-0644-ELD-SPR.  New 2000A service, panels, circuits, and lighting.  Plan check for power and energy.Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69481	19041-10002-04568	767 S ALAMEDA ST 4TH FL-SUITE 470	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM			PC Approved	06/17/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	change to an approved set, change under delta 2. change include reducing 2 panels bus size only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69482	17041-10000-12512	12655 W BLUFF CREEK DR	90094	11	102B161  1281	4211037197	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/18/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Issued	08/15/2017 12:00:00 AM	ADDRESS	33.97565	-118.41332	Installtaion of new 30 HP fire pump with remote disconnect section.  One new jockey pump also.  Master permit under application #15041-10000-00589	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69483	18041-10001-08117	20000 W RINALDI ST	91326	12	210B113   198	2701003044	A1-2D, [T]C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			12/26/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Issued	02/07/2019 12:00:00 AM	ADDRESS	34.27519	-118.57042	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE ALTERATION TO LIGHTING SYSTEM, RELOCATION OF CIRCUITS, ADDING NEW EQUIPMENT, REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT. CHANGES HAVE BEEN CLOUDED UNDER DELTA #4, #5, #6, & #7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69484	16041-10000-13275	4903 N EAGLE ROCK BLVD	90041	14	160-5A221  84	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.13536	-118.21539	CONVERSION OF EXISTING KFC TO A DEL TACO, New load less than 400A. Plan check for energy only, total area 8386sq.f.t. (indor plus outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69485	14041-20000-24012	10100 W SANTA MONICA BLVD SUITE 1650	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	09/29/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.06191	-118.41691	TI TO SUITE 1650. NEW LIGHTING AND NEW PARTITIONS. PC FOR ENERGY ONLY. 2013 BUILDING EFFICIECNY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69486	17041-10000-24068	7866 N CALVIN AVE	91335	3	189B117   545	2105012012	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.21406	-118.55532	PC for new (1)Tesla Powerwall2 (7KW) connecting to existing house panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69487	12041-20000-07544	18641 W DEVONSHIRE ST	91326	12	204B121    71	2728028023	C2-1VL, QC2-1VL, QP-1VL	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM			PC Approved	04/03/2012 12:00:00 AM	PIN	34.25808925	-118.53932955	T.I. to existing building space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69488	11041-10000-18088	8578 W PICO BLVD	90035	5	129B173    82	4303035026	C4-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM			PC Approved	08/25/2011 12:00:00 AM	ADDRESS	34.05348	-118.37795	T.I.  Restaurant remodel in the kitchen and store area.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69489	16041-10000-11611	5600 W CENTURY BLVD	90045	11	090B169    36	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/07/2016 12:00:00 AM			PC Info Complete	05/13/2016 12:00:00 AM	ADDRESS	33.94469	-118.37969	PC FOR ENERGY. T.I FOR COMMERCIAL BUILDINGTOTAL AREA 86915 SQ FT.Build# 16016-10000-07319	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69490	19041-20000-22805	423 W 14TH ST	90731	15	012B201   144	7456016011	R2-1XL-CPIO	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.73135	-118.28627	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 1.98KW DC/3KW AC. SCOPE OF WORK INCLUDES (6) PANASONIC PV MODULES WITH P400 OPTIMIZERS, AND A SE3000H-US INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69491	18041-10000-15446	13130 W SCHOENBORN ST	91352	6	192B157   637	2634025023	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.22243	-118.41958	Plan check for a 3.8KW AC / 3.97KW DC roofmounted system with (13) modules and (1) 3.8KW inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69492	10041-10000-10614	800 E 12TH ST # 117	90021	9	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			06/04/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	06/29/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	TENANT IMPROVEMENT IN A SMALL RETAIL SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69493	19041-10000-02903	1101 S ABBOT KINNEY BLVD	90291	11	108B145  1017	4239022001	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	33.99189	-118.47041	PC FOR T-24 ONLY FOR INTERIOR & EXTERIOR T.I TO (E) RETAIL STORE. SCOPE INCLUDES NEW 200A PANEL, LIGHTING RECEPTACLES AND EQUIPMENT. TOTAL AFFECTED AREA IS 3088 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69494	13041-20000-29951	5200 N LANKERSHIM BLVD	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.16511	-118.37448	T24 FOR HIGHRISE OFFICE BUILDING. SCOPE OF WORK IS ON THE 7TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69495	10041-20000-13725	916 S MAIN ST	90291	11	109-5A143 472	4286013031	C2-1	West Los Angeles	Venice	Venice		2734.00	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	33.99203	-118.47369	energy plan check office space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69496	17041-10000-42374	8500 W BEVERLY BLVD 644	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR TI WORK WITHIN A PREVIOUSLY IMPROVED RETAIL SPACE IN AN (E) SHOPPING CTR TI COMPRISED OF (N) STOREFRONT FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, CIRCUITS, LIGHTS. TOTAL AFFECTED AREA 964SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69497	17041-10000-06393	3100 W RIVERSIDE DR	90027	4	153A205   140	5434017029	C2-1D-RIO	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	Apartment			02/28/2017 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.11252	-118.268	Plan check for Title 24 only in existing building for outdoor 4 cortyards. Total area: 10,107 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69498	15041-20000-01901	5959 W FRANKLIN AVE	90068	4	150A191   161	5586014027	R3-1	Central	Hollywood	Hollywood United		1895.00	Electrical	Electrical	Apartment			03/04/2015 12:00:00 AM	04/01/2016 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	PIN	34.1055012	-118.31956142	PLANCHECK FOR POWER ONLY. TENANT IMPROVEMENT TO 49 APARTMENT UNITS. NEW 800 SERVICE, PANEL UPGRADES, NEW CKTS AND NEW HEAT PUMPS FOR EVERY UNIT .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69499	18041-20000-46947	4015 E SAN RAFAEL AVE pv1	90065	1	150A221   114	5464009001	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.10565	-118.21502	pv1install roof mounted pv system sized 5.7KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69500	15041-10000-32566	1201 E 7TH ST	90021	14	126A213   652	5147034016	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.03762	-118.24209	RENOVATION OF EXISTING 3 STORY 48 UNIT RESIDENTIAL HOTEL (NON-TRANSIENT) W/COMMUNITY ROOM, KITCHEN AND OFFICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69501	18041-10000-46189	19430 W MARILLA ST	91324	12	201B117   306	2761008017	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM			PC Approved	12/05/2018 12:00:00 AM	ADDRESS	34.24776	-118.55672	Plan check for a 3.8KW PV1 roof mounted system with (19) modules and (1) 3.8KW centeral inverter interconnecting through the service panel.Note. Permit fee is paid under 18041-90000-38607.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69502	16041-20000-01478	5518 N RIVERTON AVE	91601	2	174B177   831	2416017023	R1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.17059	-118.36543	Plan check for PV roof monted. System size: 3.8kW with 12 modules and 1 inverter(3.8kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69503	14041-10000-14517	1149 S HILL ST 5TH FL	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/02/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Expired	07/14/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	TENANT IMPROVEMENT IN CORRIDORS IN THE OFFICES  OF USC SCHOOL OF SOCIAL WORKPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69504	14041-10000-16946	921 S CROCKER ST #C01; C02	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Closed	11/09/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	First tenant in renovated buildingcore and shell permitted 13041-10000-22477	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69505	19041-10000-08339	755 S SPRING ST #101	90014	14	127-5A211 157	5144015240	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.04336	-118.25369	Full plan check for a first time tenant (icecream shop) located on the ground floor of a highrise building, Scope includes new lighting and equipment with a total area of 546-SQ FT. Building Application #: 19016-10000-06591.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69506	14041-10001-02190	331-335 S BROADWAY	90013	14	130-5A211 111	5149015018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM			Reviewed by Supervisor	06/23/2014 12:00:00 AM	ADDRESS	34.05037	-118.24893	VOID APPLICATION, NEW DESIGN SUBMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69507	10041-20004-17057	825 E 4TH ST 1-53	90013		127-5A215 174	5163011028	M3-1		Central City North	Historic Cultural			Electrical	Electrical	Apartment			10/02/2012 12:00:00 AM			PC Approved	10/02/2012 12:00:00 AM	ADDRESS	34.0435	-118.23728	Changes to outdoor lighting from 10041-20003-17057.  Added notes to plan per inspector (non-plan check items). Plan check for energy only. 21220 sqft outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69508	17041-10000-14113	12050 W VENTURA BLVD A-105	91604	2	162B165   141	2369015019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM			PC Info Complete	04/28/2017 12:00:00 AM	ADDRESS	34.14349	-118.39426	PC for energy only, Indoor Title-24. TI to an existing bank. Adding new partition walls lighting and power on 1st floor for new teller line counter top. Total area: 1,375 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69509	19041-10000-06993	412 S SEATON ST	90013	14	127-5A215 280	5163025002	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	12/15/2021 12:00:00 AM		Issued	12/15/2021 12:00:00 AM	ADDRESS	34.04293	-118.23746	FULL PLAN CHECK FOR A CHANGE OF USE  TO BANQUET HALL WITH LIVE ENTERTAINMENT LOCATED IN A SINGLE STORY COMMERCIAL BUILDING (1 OUT OF 4 BUILDINGS IN A SAME PARTIAL WITH DIFFERENT ADDRESS). SCOPE INCLUDES NEW SERVICE, NEW LIGHTING AND EQUIPMENT WITH A TOTAL AREA OF 12,336-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69510	15041-20004-13268	13920 W VAN NUYS BLVD 101-106	91331	6	204B153   484	2645001025	[Q]C2-1VL-O	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM			PC Approved	07/06/2016 12:00:00 AM	ADDRESS	34.25584	-118.43585	07-05-2016 Changes to an approved set of plans. Changes include Disaggregation of Electrical Circuits in 3 differen panels[A(Lighting Load),K( Equipment Load), and P(HVAC Load)] and Controlled receptacle in office area. Changes apply to delta 1 only. {{{{Plan check for power and energy to Building Addition to existing space. New service and equipment rated for 800A with mutiple tenants. Total area: 19,951 sq ft.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69511	18041-20000-35015	8545 N HATILLO AVE	91306	3	192B113    95	2782016011	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Re-Activate Permit	10/21/2019 12:00:00 AM	ADDRESS	34.22574	-118.56523	pv1install roof mounted pv system sized 13.8KW AC interconnected with msp.Fees $0.0 due to California Senate Bill 1222 and Assembly Bill 1414	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69512	16041-10000-42858	22243 W ROMAR ST	91311	12	204B101   335	2745011057	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.25506	-118.61219	PC FOR ROOF MOUNTED PV SYSTEM. TOTAL OF 29 MODULES USING AC MODULE SYSTEM	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69513	19041-10000-40047	10330 W ROSSBURY PL	90064	5	123B161    31	4318026009	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.03722	-118.40964	FULL PLAN CHECK FOR THE ADDITION OF TWO TESLA POWERWALLS TO AN EXISTING SOLAR SYSTEM. MAIN PANEL UPGRADE TO BE SEPERATELY PERMITTED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69514	12041-20000-01606	1413 E 20TH ST	90011	9	120A211   351	5129005011	[Q]CM-1	South Los Angeles	Southeast Los Angeles	South Central		2260.00	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	05/09/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.02162	-118.24853	T24 and emergency lighting plan check only for new one story warehouse building. Service is only 400 amperes.  Original submittal to building plan check is  100' X 160' 1 STORY TYPE III-B SPRINKLERED WAREHOUSE W/ 35' X 75' MEZZANINE AND ROOF TOP PARKING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69515	18041-20001-45471	10746 N BAILE AVE	91311	12	207B117   493	2708027027	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	34.26576	-118.56243	Revisions to approved plans.  (E) MSP bus and main breaker configuration modified to reflect field conditions. $0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.(((Plan check for PV roof mounted system, system size: 10.23kW DC, 9.554KW AC with 31 PV Modules and 1 inverter(10.0kW).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69516	18041-10001-21358	3900 N HOLLYLINE AVE	91423	4	162B153   403	2272002033	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.14088	-118.43872	Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69517	18041-10000-45927	5901 W SUNSET BLVD	90028	13	147A191    64	5545009033	(T)(Q)C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	02/05/2021 12:00:00 AM	ADDRESS	34.09822	-118.31812	PERMIT FEES ARE $0 DUE TO AB 1222.PV3. DC BUILDING INTEGRATED PV SYSTEM ON A NEW COMMERCIAL BUILDING. TOTAL SYSTEM SIZE IS 30.0KWac.(313)MODULES-WW-100 PV MODULES(3)INVERTERS-SOLAREDGE SE10KUS(123)OPTIMIZERS-SOLAREDGE P400	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69518	19041-10000-31187	450 S WESTERN AVE SUITE 315	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2118.04	Electrical	Electrical	Commercial			08/09/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.06562	-118.30887	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69519	19041-10000-04228	10390 W SANTA MONICA BLVD #340	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	05/23/2020 12:00:00 AM	ADDRESS	34.05734	-118.42365	FULL PLAN CHECK POWER AND T-24 FOR TENANT IMPROVEMENT TO 9,500 SF MEDICAL CLINIC (OUT PATIENT FACILITY) SUITE, OSPHD 3 - NON INVASIVE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69520	10041-10001-20370	5150 W WILSHIRE BLVD 2nd, 3rd &-4th Flrs	90036	4	132B181    35	5507025021	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM			PC Approved	05/02/2011 12:00:00 AM	ADDRESS	34.06202	-118.3421	TI IN AN EXISTING OFFICE BUILDING ON THE 2ND, 3RD & 4TH FLOORS.          PLAN CHECK IS FOR POWER & ENERGY.   <<<<<<<<<<<CHANGE TO APPROVED SET OF PLANS.  CHANGED LIGHTING ON 3RD FLOOR AND DELETED DISTRIBUTION PANEL DB, REPLACED 400A BREAKER WITH 150A BREAKER AT BOARD.>>>>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69521	16041-10001-15193	3036 S CRENSHAW BLVD	90018	10	120B185   733	5051029031	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2193.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	PIN	34.02620528	-118.33468916	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF CANOPY LIGHITNG. PC FOR UPDATED PLANS AND TITLE 24 CALCS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69522	18041-10000-09590	11216 W PENDLETON ST	91352	6	198B173   115	2408034047	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Issued	03/16/2018 12:00:00 AM	ADDRESS	34.23654	-118.3756	REPLACE INDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69523	15041-20000-07189	6300 W WILSHIRE BLVD 10th floor	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM			PC Approved	03/19/2015 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for Title 24. Project is a TI to the 10th floor of a high-rise building. Total lighting area = 18,690 sq. ft. plan check for power is under supplemental application. electrical permit to be pulled under the subplemmental.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69524	12041-20000-27487	2815 W SUNSET BLVD 1st FLoor	90026	13	141A205    48	5402001040	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Issued	11/14/2012 12:00:00 AM	ADDRESS	34.08216	-118.27195	Plan check for energy and emergency lighting. Low rise office space. 1st floor. 1058sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69525	12041-10000-09691	10400 N SEPULVEDA BLVD	91345	7	204B145   113	2649019009	C2-1, P-1, R1P-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Info Complete	07/27/2012 12:00:00 AM	ADDRESS	34.25939	-118.46706	TI IN AN EXISTING RALPHS STORE. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69526	16041-10000-14524	111 E UNIVERSAL HOLLYWOOD DR 17th flr	91608	4	162B177   624	2424043019	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		3200.00	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.13855	-118.36112	T.I. on 17th floor of (E) office building. New panel with connected load 27A. PC for T-24 only. Total area: 19,530 sq.ft.B# 16016-10000-08911	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69527	19041-20000-09710	3290 W SLAUSON AVE	90043	8	105B185  1434	4005005032	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	33.9886	-118.32995	T24 FOR TI TO EXISTING COMMERCIAL BANK SPACE. NEW LIGHTS INDOOR AND OUTDOOR, AND NEW OUTLETS. TOTAL SQUARE FOOTAGE = 18,446 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69528	16041-10003-01886	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR CHANGES UNDER DELTA 37. IN REFERENCE WITH MASTER APPLICATION  10000 (APPROVED)  SCOPE INCLUDES NEW PANEL AND BRANCH CIRCUITS. ADDITION OF AREA TO TITLE 24 DOCUMENTS AND NEW ADDED LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69529	14041-20000-18921	318 N GOODHOPE AVE	90732	15	018B189    83	7559008025	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	33.74639	-118.31605	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(15) SOLAR WORLD SW275M MODULES(1) POWER ONE PVI 5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69530	12041-10002-04924	19310 S PACIFIC GATEWAY DR	90502	15	057B197     9	7351031030	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	10/07/2013 12:00:00 AM	ADDRESS	33.85616	-118.29473	DELTA 3 CHANGES TO APPROVED PLANS. REPLACE THE ELECTRIC FIRE PUMP WITH A DIESEL FIRE PUMP.  THE LOCATION OF THE NEW FP & FUEL TANK MUST BE APPROVED BY THE LAFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69531	15041-10000-26648	10526 N PLAINVIEW AVE	91042	7	207B197  1357	2557022006	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	11/02/2015 12:00:00 AM	ADDRESS	34.26034	-118.29779	PV1, INSTALL NEW 9.88 KW DC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOUSE.(38) MODULES: KYOCERA KU2606XPA(2) ABB PVI-3.6-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69532	15041-20000-22858	14059 W AZTEC ST	91342	7	219B153    19	2508010021	R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Issued	07/17/2015 12:00:00 AM	ADDRESS	34.30096	-118.43954	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Central inverter (standard plan used).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69533	18041-20001-04912	610 S VAN NESS AVE	90005	4	135B189   927	5504018011	RD3-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Apartment			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.06273	-118.3152	07-12-2018 Changes to an approved set of plans. Changes include relocate panels to garage location. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69534	19041-20000-25140	1318 N BEVERLY GLEN BLVD	90077	5	147A153   458	4371030014	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Expired	09/19/2023 12:00:00 AM	ADDRESS	34.09704	-118.44109	addition of (3) tesla ESS to an existing PV system.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69535	19041-20000-17918	5841 N MCDONIE AVE pv1	91367	3	174B113    15	2151005027	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2019 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.177	-118.57333	pv1install roof mounted pv system sized3.8KW AC interconnetced with msp.  This is an addition to an existing pv system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69536	14041-20000-13167	10921 W ART ST	91040	7	201B173   206	2542011008	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.24865	-118.36837	Change from previously approved plans (14041-20000-10828).  Change in upside AC conductors only.  No changes in modules type, inverter type, and roof module location.Note: Permit is under the previously approved plans.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69537	11041-10000-22185	852 S BROADWAY	90014	14	127-5A209 220	5144016059	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	12/22/2011 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.04246	-118.2557	Change of use from retail to restaurant in a high-rise building.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69538	12041-20000-26951	6439 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Approved	11/08/2012 12:00:00 AM	ADDRESS	34.18759	-118.59772	New addition to an existing restaurant.  Load is less than 400 amps and occupancy load is less than 99, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69539	17041-10000-42640	3015 S CRENSHAW BLVD	90016	10	120B185   496	5050031061	C2-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	34.02711	-118.33529	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69540	19041-20000-38619	4309 N BELLINGHAM AVE	91604	2	165B165   641	2367003046	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Issued	09/25/2019 12:00:00 AM	ADDRESS	34.14888	-118.39882	Plan check for PV roof mounted system, PV system size: 5.6KW with 14 AC Modules  and 1 sub-panels.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69541	12041-20000-05857	17945 W CHATSWORTH ST #32	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM			PC Approved	04/25/2012 12:00:00 AM	ADDRESS	34.26501	-118.52506	Wells Fargo Home Mortgage office t.i.Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69542	15041-20000-28149	5940 N LAUREL CANYON BLVD	91607	2	177B165   866	2340005036	C2-1VL, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM	02/10/2016 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.17857	-118.3963	TI to existing commercial building. Plan check for energy only. Adding new lighting including emergency. Total sqft. 1,971.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69543	12041-10000-09396	616 S STANFORD AVE	90021	14	126A213   213	5147029041	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	04/24/2012 12:00:00 AM		Permit Finaled	08/15/2012 12:00:00 AM	ADDRESS	34.04026	-118.24307	"Replace/Repair to an existing cold storage area in an existing seafood cold storage warehouse.  Change to lighting and refrigeration equipment.  PLAN CHECK ONLY for Energy,  with Emergency lighting.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69544	12041-20000-10850	11835 W OLYMPIC BLVD	90025	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	PIN	34.03318579	-118.45141815	Ti for existing office. Plan check for energy. 825 conditioned sqft. High-rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69545	18041-10000-11098	4909 W ROSEWOOD AVE	90004	4	141B193  1309	5522017011	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Public Safety Only			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.07943	-118.31179	NEW FIRE WARNING SYSTEM FOR 4-STORIES 26 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69546	17041-10000-03932	13332 W WASHINGTON BLVD	90066	11	108B153  1302	4230008020	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	33.99266	-118.44299	REPLACE HIG FIXTURES WITH LED TYPE TO REDUCE POWER CONSUMPTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69547	15041-20000-10741	13100 N ELDRIDGE AVE	91342	7	225B161    47	2580015904	OS-1XL	North Valley	Sylmar	Sylmar		1061.11	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.30942	-118.41434	Plan check for T-24 only. Total 1023 sq ft  for El Cariso Golf Course	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69548	18041-10000-05033	344 S AVENUE 17	90031	1	136-5A219 176	5447029019		East Los Angeles				1997.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.06809	-118.22151	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES  ADDING NEW LIGHTS FOR WAREHOUSE AND RESTROOM SPACES. TOTAL AFFECTED AREA IS 1000 SQ. FT.  B#18016-10000-00743	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69549	15041-10000-27656	777 S SANTA FE AVE CMU	90021	14	124-5A217 323	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.03354	-118.23024	RENOVATION OF EXISTING WAREHOUSE CONSISTING OF THREE BUILDINGS. (1) 2 STORY CMU BUILDING(1) 2 STORY ANNEX BUILDING (1) 5 STORY TOWER.COMPLETE REBUILD.  PLAN CHECK FOR POWER AND ENERGY.  THIS APPLICATION TO COVER BUILDING CMU ONLY.BUILDING APPLICATION UNDER 14016-10001-21080	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69550	17041-20001-42583	20048 W LEMARSH ST	91311	12	204B113   372	2726024023	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	34.25503	-118.57058	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp.  center fed panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69551	12041-10000-13895	625 N NEW HAMPSHIRE AVE	90004	13	141B197   656	5538029041	R3-1	Central	Wilshire	East Hollywood		1926.10	Electrical	Electrical	Commercial			06/15/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.08253	-118.293	Fire alarm (panel replacement) for a retirement home.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69552	18041-10000-37733	22968 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Issued	10/03/2018 12:00:00 AM	ADDRESS	34.18624	-118.62736	REPLACING EXISTING OUTDOOR LIGHTING WITH NEW LED FIXTURES. T-24 CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69553	14041-10000-25183	2915 E 11TH ST	90023	14	120A221   178	5170025015	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	03/13/2015 12:00:00 AM		Issued	03/13/2015 12:00:00 AM	ADDRESS	34.02151	-118.21551	PC FOR POWER ONLY FOR SERVICE UPGRADE AND REMODEL OF EXISTING WAREHOUSE. SERVICE SIZE 600 AMPS. ENERGY APPROVED UNDER APPLICATION#: 14041-10000-32207	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69554	14041-10000-18030	1055 W 7TH ST 33rd Floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			07/03/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.0507	-118.26334	Title 24 plan check only.  Total area = 17880 sq. ft.TI for existing office highrise. BLDG#14016-10-11950 entire 33rd floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69555	16041-10000-00049	123 S MYERS ST	90033	14	129A217   117	5172013002	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.04706	-118.22887	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING WAREHOUSE FACILITY. SCOPE INCLUDES ADDING NEW LIGHTS TO OFFICE, CONFERENCE, LOUNGE, AND SERVICE AREA. TOTALAFFECTED  AREA IS 2240 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69556	19041-20000-44177	3335 N LAUREL CANYON BLVD	91604	2	159B169   417	2381002005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Issued	12/04/2019 12:00:00 AM	ADDRESS	34.13226	-118.38852	PV1.  Install 3.78 kW roof mounted grid tied PV system and 13.5 kWh energy storage system.  (12) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69557	14041-20001-07515	12059 N DELANTE WAY	91344	12	216B125   380	2601072012	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.29185	-118.52743	Fee for expedite only.*****Roof mounted PV system with 8.10 KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69558	12041-10000-18774	16242 W JERSEY ST	91344	12	207B137   198	2680008004	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2012 12:00:00 AM	09/14/2012 12:00:00 AM		Permit Finaled	09/21/2012 12:00:00 AM	ADDRESS	34.26691	-118.48624	New rootop photovoltaic system using Enpahse microinverters for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69559	16041-10000-31900	6245 W WILSHIRE BLVD	90048	5	135B177   481	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	03/23/2018 12:00:00 AM	ADDRESS	34.06356	-118.36478	Installation of a new fire alarm system to a new high rise building. Installing (1) Fire alarm panels, (5) communication panels, (6) powwer supply boosters, and (772) fire alarm devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69560	16041-20000-00990	8156 N BURNET AVE	91402	6	192B145   582	2209006010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.21956	-118.46344	Plan check for PV roof mounted system. System size: 5.5kW with 22 pv modules and 22 microinverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69561	19041-10000-44089	1710 N CHEROKEE AVE	90028	13	148-5A185  58	5547004901	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	01/07/2020 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.10235	-118.33462	POWER PLAN CHECK FOR NEW INSTALLATION OF THREE LEVEL 3 CHARGERS. SCOPE INCLUDES NEW 800A PANEL CONNECTED TO AN EXISITING 1600A SERVICE 120/208 3PH, 4W [LINE SIDE].	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69562	17041-20000-41183	510 S SPRING ST	90013	14	129A211   134	5149036004	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Issued	11/28/2017 12:00:00 AM	ADDRESS	34.047	-118.24978	Addition of (1) 160KVA UPS for power quality improvement for standby service elevators on the 12th floor.  No change in load.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69563	16041-20000-07570	14834 W NORDHOFF ST	91402	6	195B149     9	2651014015	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.23524	-118.45647	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING FOR PRIVATE RESIDENTIAL TRACT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69564	19041-10000-53205	3345 W WILSHIRE BLVD #3	90010	10	135B197  1214	5502028020	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2121.01	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	01/17/2020 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.06193	-118.2963	T-24 PLAN CHECK FOR A TI TO EXISTING SPACE WITH CHANGE OF USE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 3270 SQ.FTB#19016-10000-38601	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69565	16041-20000-03891	12038 W VENTURA BLVD #A,#B,#C	91604	2	162B165   133	2369015016	(Q)C2-1VL-RIO, (Q)P-1VL-RIO, C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/03/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.14352	-118.39381	PLANCHECK FOR T24 ENERGY.  PLANCHECK ONLY.  CHG OF USE FROM RETAIL TO 1102SF PHARMACY, 998 SF YOGA STUDIO , 656 SF  RETAIL STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69566	17041-20000-31630	2100 W 3RD ST Suite 200	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.06281	-118.2731	Plan check for power and energy. Project site is a portion of the 2nd floor of an existing commercial building. Project scope is a change of use from research lab to medical clinic/tenant improvement. Total lighting area = 19,368 sq. ft.Note: Building application has been generated under 17016-10001-25147.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69567	18041-10000-45094	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	02/25/2019 12:00:00 AM		Permit Finaled	02/17/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	Power plan check for baggaging equipment located in the new terminal (Midfield Satellite Concourse), Building A. Scope include multiple motor under each ckt from subcontrol panel and main control panel.LAX project; Applicant request Mehdi for the application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69568	12041-10001-06970	12301 W PICO BLVD	90064	11	126B157   893	4255028005	[Q]C2-1D, [Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles, Westside		2676.00	Electrical	Electrical	Commercial			09/13/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.02858	-118.45242	CHANGES TO APPROVED SET OF PLANS. 111 CKTS, 7000 T24, 2 PANEL 800 AMP , 1 PANEL 600 AMP, 1 PANEL 200 AMP.New 95 unit condominium project with Live/Work space on the 1st floor.  5-story building.  2000A service size.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69569	17041-20000-35682	4274 N PERLITA AVE	90039	13	159B205   752	5594010016	(Q)RD2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2017 12:00:00 AM			Reviewed by Supervisor	10/12/2017 12:00:00 AM	ADDRESS	34.13132	-118.26836	installation of (2) tesla powerwalls.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69570	14041-20000-04183	6612 W LELAND WAY	90028	13	147A185   165	5547025010	RD1.5-1XL	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.09686	-118.33375	Roof mounted PV system with 1.5KWdc, transformerless,	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69571	14041-10000-34497	3470 W WILSHIRE BLVD B-1	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Issued	12/29/2014 12:00:00 AM	ADDRESS	34.06152	-118.3001	TI to (E) commercial restaurant space - karaoke bar.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69572	14041-20000-12203	11810 W GLAMIS ST	91342	7	210B169   944	2530029015	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.08	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.2764	-118.38992	Roof mounted PV system with microinverter, model M215-60-2LL, Mfr. Enphase.  System size 3.89KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69573	12041-10000-17337	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM			PC Approved	12/04/2012 12:00:00 AM	ADDRESS	34.2392	-118.55379	Change to lighting and receptacles to an existing retail space in Northridge Fasion Plaza.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69574	14041-20000-03254	11100 W SANTA MONICA BLVD 15TH  &-16TH	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.04726	-118.44465	PC FOR T24 ENERGY ONLY. LIGHITNG DONE IN OFFICE AND CORRIDOR. CORRIDOR FOR 3 LEVELS AND COMPLETE LEVEL FOR OPEN OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69575	13041-20000-20370	4371 S GLENCOE AVE STE B9-B	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Approved	07/31/2013 12:00:00 AM	ADDRESS	33.9857	-118.43834	Plan check for energy and emergency lighting. Low-rise commercial. European Wax Center. Suite B9-B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69576	13041-10001-36018	14501 W SAN JOSE ST	91345	7	207B149   727	2648019013	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	ADDRESS	34.26163	-118.44877	Expedited RSES plan check per applicant request.{{PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (16) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69577	11041-10000-15674	23122 W CALVERT ST	91367	3	177B097   389	2039008017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2011 12:00:00 AM	08/16/2011 12:00:00 AM		Permit Finaled	08/22/2011 12:00:00 AM	ADDRESS	34.18084	-118.63057	NEW ROOF-TOP PV SYSTEM FOR AN EXISTING SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69578	15041-20000-29153	2120 E 7TH PL	90021	14	124-5A217 345	5166003006	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM	10/26/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.0334	-118.22912	TI TO AN EXISTING COMMERICAL BUILDING (SHOW ROOM AND FURNITURE DISPLAY). FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AREA IS 6807 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69579	14041-10000-22724	1050 S GAYLEY AVE	90024	5	132B149   271	4363024021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.06115	-118.44706	Title 24 plan check only.  Total area = 193 sq. ft.Construct passenger elevator and machine room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69580	18041-20000-09956	3924 N HILTON HEAD WAY	91356	3	162B125   133	2184052012	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.14245	-118.53302	Plan check for a PV1 roof-mounted PV system. System size is 11.52 kWac and consists of (36) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69581	13041-10000-29470	20263 W INGOMAR ST	91306	3	189B113  1066	2107012042	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.21171	-118.57515	PV1, $0 Permit fee due to 2012 SB 1222. Installing roof-mounted photovoltaic system interconnect with main panel. System size: 11.5 KW DC with Solaredge transformerless inverter, Trina modules with power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69582	19041-20000-24250	20700 W SESNON BLVD #175-pv1	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	pv1install roof mounted pv system sized 5.25KW AC interconnected with  msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69583	12041-10000-17970	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	TI FO RTHE FIRST CLASS LOUNGE AND JOINT LOUNGE AT THE EXISTING AND NEW 5TH FLOOR OF THE TOM BRABLY TERMINAL  AT  LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69584	13041-20001-24806	12852 W RUNWAY ROAD PV-2	90094	11	102B161  1221	4211033040	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	ADDRESS	33.97543	-118.41892	Expedite Fee.PV-2. Plan check for PV system for community center. One 75kW inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69585	17041-10000-34983	1426 S PALOMA ST	90021	14	121-5A211  47	5132022036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.02881	-118.24943	PC for T24 only for outdoor lighting. Replacing HID fixtures and replacing with new LEDfixtures. Total area 15700sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69586	13041-20001-36073	19542 W VOSE ST	91335	3	183B117   441	2130031016	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	01/04/2014 12:00:00 AM	ADDRESS	34.19825	-118.55936	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 6KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69587	15041-10000-00947	1537 N NORFOLK ST	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	05/25/2016 12:00:00 AM	ADDRESS	34.06138	-118.20223	Plan check for Power for Doheny Eye  Institute. Replace existing 2 ATSs, 2 Transformers 2 distributaion boards and new feeder for the ATS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69588	16041-20000-37749	5601-5667 W SANTA MONICA BLVD	90038	13	144B193   593	5536012014	(T)(Q)RAS4-2D	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			11/29/2016 12:00:00 AM			Reviewed by Supervisor	01/06/2017 12:00:00 AM	ADDRESS	34.0909	-118.31159	Temporary power for construction. 1600A 480Y/277V service. Installing temporary cranes, elevators, transformers and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69589	18041-10000-19898	6360 W MARYLAND DR	90048	5	135B173   525	5510017023	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.06707	-118.3668	PC FOR ROOF MOUNTED PV ON SFD.SCOPE INCLUDES 33 MODULES WITH 2 INVERTERS AND NEW LOAD CENTER. TOTAL SYSTEM SIZE 10.75KWDC /10.4KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69590	19041-30000-25471	2049 S CENTURY PARK EAST 38TH FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	ENERGY PC FOR T. I. RENOVATION TO PUBLIC Restroom.  AREA 410SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69591	17041-10000-22900	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR T24 ENERGY ONLY FOR STOCKROOM LIGHTING UPGRADES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69592	12041-10000-06354	13488 W MAXELLA AVE	90292	11	105B153    78	4212004012	[T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	Plan check T-24 Energy (general/emergency) lighting for interior TI for FEDEX Office store. New load less than 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69593	08041-10001-06267	609 S ST PAUL AVE	90017	1	130-5A207  24	5143025002	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Apartment			05/11/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.05337	-118.26134	REVISIONS TO a previously approved set of plans.  No permit was ever issued for the original set of approved plans.  ON THE RESIDENTIAL  SWBD, USE BUSWAYS  INSTEAD OF CONDUCTORS TO SUPPLY THE  METER SECTIONS; ON THE HOUSE SWBD, REDUCE THE SERVICE FROM 4000A TO 2000A, REDUCE THE AMPERE RATING OF THE FEEDER CB'S, THE ATS, AND INCREASE THE HP RATING OF THE ELEVATORS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69594	11041-10000-01572	512 E ROSE AVE	90291	11	111B141   916	4240009051	C4-1, RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			01/26/2011 12:00:00 AM	01/26/2011 12:00:00 AM		Permit Finaled	03/28/2012 12:00:00 AM	ADDRESS	33.99813	-118.47363	new fire warning system for a 70 units 3-stories apartment building above 2levels garage	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69595	18041-20000-31955	801 S FIGUEROA ST #950	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 Energy only in existing space T.I. high-rise building. Total area; 3320 sq ft.B#18016-10000-23451	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69596	19041-20000-35733	18820 W KILFINAN ST	91326	12	219B121    29	2820005008	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.29751	-118.54371	PV1. INSTALL 8.19 KW DC ROOF MOUNTED SOLAR SYSTEM WITH (26) MODULES AND OPTIMIZERS AND (1) SE7600H INVERTER. SCOPE OF WORK INCLUDES (1) TESLA ENERGY STORAGE SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69597	13041-10000-24961	10014 N WISH AVE	91325	12	204B133   601	2694017014	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.25271	-118.50776	PV1 4KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: SOLAREDGE SE3800A-US] [( 16) MOD: Trina {TSM-250PA05.08}  with optimizers {POWERBOX 250W OP250-LV-MC4SM-2NA}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69598	16041-20000-02580	5410 N RHODES AVE	91607	2	171B165    39	2347006***	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			01/25/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Expired	03/02/2018 12:00:00 AM	ADDRESS	34.16912	-118.40293	Install a roof mounted solar array on an apartment building. Interconnect with a 400A MSP.System size: 8.2kW + 6kW = 14.2kW, ungrounded system. (63) 265W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69599	15041-20001-26776	5618 E MARMION WAY	90042	1	151-5A229 171	5468033024	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM			PC Approved	10/22/2015 12:00:00 AM	PIN	34.1101604	-118.19429797	Expedited per customer request.PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel.(26) Sunpower 327W Modules(2) PVI 3.8 Inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69600	17041-10000-22841	13286 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	33.97878	-118.43604	PC FOR POWER AND ENERGY FOR DENTAL CLINIC. TOTAL AFFECTED AREA IS 1466 SQ. FT.  B#17016-10000-18456	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69601	15041-10001-19354	4151 W PROSPECT AVE BLDG A	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	8/7/15: (supplemental) for T-24 only.1. Replace light fixture 4*4 to 2 2*2 fixtures2. Relocate 1 existing panel3. Added receptaclesPermit to be pulled on master application. ((T-24 ONLY TO AN (E)  2 STORY OFFICE BUILDING. SCOPE OF WORK INCLUDES ALL NEW LIGHTING IN BASEMENT, PC FOR ENERGY ONLT. TOTAL SQ. FT. 2153.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69602	13041-10005-26820	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			08/10/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	33.97574	-118.39042	8/10/2015CHANGE OF ENGINEER.  APPLICANT TO SUBMIT LETTER FROM ORIGINAL ENGINEER/OWNER BEFORE PERMITTING.  PLAN CHECKER TO VERIFY LETTER FOR CHANGE OF ENGINEER BEFORE FINAL APPROVAL OF PLANS.  CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 7. CHANGES INCLUDE REVISIONS TO THE LIGHITNG FIXTURES AND REVISIONS TO THE ENERGY CALCS.New 218-unit apartment building at Howard Hughes Center.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69603	17041-20001-42949	840 N OGDEN DR	90046	5	141B177    49	5527004004	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	34.08657	-118.35935	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6.6 kWac and consists of (1) inverter, (25) modules, (1) load center, and (1) battery unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69604	14041-20000-09886	8428 N LURLINE AVE	91306	3	192B109   419	2780026008	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.22298	-118.58401	PV1.  Install 6.5 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69605	10041-10000-01899	1458 S SAN PEDRO ST	90021	9	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	02/05/2010 12:00:00 AM		Permit Finaled	02/10/2010 12:00:00 AM	PIN	34.03045627	-118.25434986	TI - changes to previously approved plans - addition of new track lighting ->2008 T-24 calculations.  P/C is for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69606	16041-10000-39366	8640 W 3RD ST #201	90048	5	138B169   564	4334011021	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/07/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.07338	-118.38114	Full PC for power and energy. TI WORK FOR NEW DENTAL OFFICE(General care only, non invasivie procedures). Scope includes adding new circuits and lights for a dental office. Total affected area is 1197 Sq. Ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69607	14041-20000-17234	11332 W CHENAULT ST	90049	11	135B149   595	4365010031	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.06259	-118.45851	PV1.  Install 5.8 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.Zoning clearance obtained before starting of this application under 14041-20000-17206	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69608	18041-20000-46863	13267 W SEVILLANA WAY	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.31534	-118.42258	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) micro-inverters and (7) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69609	15041-10000-04179	14601 W VENTURA BLVD	91403	4	166-5A151  87	2265005011	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.15149	-118.45104	Plan check for Title 24 only. The scope of work for this plan check only covers outdoor lighting and a change of EMS manufacturer. Title 24 plan check for indoor lighting can be found under application number 14041-10000-31644.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69610	15041-20003-43046	964 S BERENDO ST PHASE 2	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.05378	-118.29358	"[[[[7/11/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA "" L "" CHANGES. REVISION OF LOADS AND ADDITION OF CIRCUITS IN THE PANELSCHEDULES FOR RECEPTACLES, TVS, SFD'S, WIFI AND PROJECTIONS SCREENS, MINOR CHANGES TO LIGHTING]]]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69611	13041-20000-21170	14975 W CORONA DEL MAR	90272	11	123B129   690	4411024004	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.03146	-118.52224	PLAN CHECK FOR NEW HOUSE. 800A SINGLE PHASE SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69612	17041-20000-39721	10337 W CARIBOU LANE	90077	5	150B153   759	4380021018	RE40-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	11/27/2017 12:00:00 AM	PIN	34.10504083	-118.44431592	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5.355 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69613	14041-10000-32593	3318 N FITHIAN AVE	90032	14	142-5A233 305	5213016026	R1-1	East Los Angeles	Northeast Los Angeles	LA-32		2014.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.08419	-118.17993	Plan check for a roof-mounted PV system. System size is 4.2 kWac. System consists of (14) inverters and (1) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69614	18041-20000-45553	14834 W MAPLE TER	91402	6	195B149   774	2651022035	(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.08	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	34.23465	-118.45652	pv1install roof mounted pv systemn sized 5Kw AC interconnected with msp.this is plan check only, permit fees paid under application number 18041-90000-44051	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69615	10041-20001-12992	6828 N VAN NUYS BLVD	91405	6	183B149   704	2217009016	(Q)RAS4-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Apartment			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.19475	-118.44846	NEW MIX USE 68 UNIT APT BLDG ((supplemental. new exterior lighting. new outdoor t24. pc for t24 energy only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69616	16041-10000-01184	2330 S WALNUT AVE	90291	11	108B149    30	4242031008	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Expired	02/12/2018 12:00:00 AM	ADDRESS	33.99611	-118.45047	PV1, Install 3.77 kW DC roof-mounted solar array, interconnect with service panel. Transformerless (1)Inverter.: ABB PVI-3.6-OUTD-S-US-Z-A. (13) modules SILEVO TRIEX U290 BLACK	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69617	13041-10000-22033	1026 S ALFRED ST	90035	5	132B173   454	5087006025	R2-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/13/2014 12:00:00 AM	ADDRESS	34.05855	-118.3748	PV1 ROOF-MOUNTED INSTALLATION ; SYSTEM SIZE AT 7 KW. (28) MODULES: PHONO 250P-20/U(28) ENPHASE M215	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69618	19041-10000-27892	10020 S AVALON BLVD 1-4	90003	8	091-5A207 103	6050036023	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Apartment			07/22/2019 12:00:00 AM			PC Approved	08/20/2019 12:00:00 AM	ADDRESS	33.94493	-118.26485	PLAN CHECK ONLY, PERMIT FEES HAVE BEEN PAID FOR UNDER SEPARATE APPLICATION. _____________________________________________Building 1 of 5: Note. 5 applications under 1 plan, main service located in bld # 3Full plan check for power and energy for service upgrade to 600A for 22 residential units split up into muiltple buildings. Scope of work includes a new 600A serivce, new resedintial panels, and a new 600 A distribution board. Note building has provided 5 different building numbers for each building, 5 applications were genrated  under one planNote the service will be charged under building 3, and the square footage will be charged under building 3 as well ELECTRICAL Buiding 1: 19041-10000-27892*Building 2: 19041-10000-28073Building 3: 19041-10000-28077Building 4: 19041-10000-28079Building 5: 19041-10000-28081Building 1 B#: 17014-40000-00543*Building 2 B#:17014-40000-00545Building 3 B#: 17014-40000-00546Building 4 B#: 17014-40000-00547Building 5 B#: 17014-40000-00548	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69619	13041-20003-06699	10635 N WOODMAN AVE	91345	7	207B149   430	2648004045	(T)RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.26343	-118.45534	CHANGES TO APPROVED SET DELTA 1 ONLY ADD EMERGENCY LIGHT FOR KITCHEN AND STAIRWELL PROVIDE PHOTOMETRICS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69620	19041-10000-53826	303 N SAN FERNANDO ROAD	90031	1	139-5A219  48	5447007901	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	04/20/2022 12:00:00 AM		Issued	04/20/2022 12:00:00 AM	ADDRESS	34.07693	-118.22302	INSTALLING 2 @ 50HP CARBON SCRUBBERS AND OTHER LOADS IN HAZARDOUS, CLASS I - DIVISION 2 AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69621	14041-10000-31799	819-823 E MANCHESTER AVE	90001	9	097-5A209 244	6029030003	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2398.02	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Approved	04/29/2015 12:00:00 AM	ADDRESS	33.96032	-118.26004	New single Story building for auto-repair garage with new service 200 amps. Plan check for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69622	09041-10001-21638	2402 E ANAHEIM ST	90744	15	030B213   113	7440002***	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	01/26/2010 12:00:00 AM		Permit Finaled	04/20/2010 12:00:00 AM	ADDRESS	33.78054	-118.23195	ADDING SMOKE DETECTORS AND DUCT SMOKE DUCTORS AND REMOTE TEST STATIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69623	17041-20000-16281	23280 W HARTLAND ST	91307	12	183B093   638	2026020030	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.19445	-118.63431	pv1install roof mounted pv system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69624	13041-20001-19780	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM			PC Info Complete	10/16/2013 12:00:00 AM	ADDRESS	34.05886	-118.41642	Modification to previously approved set of plans.  Changing connection, new EDM, changes.        <<<Plan check for power for fuel cell installation. Fees to be verified during plan check.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69625	14041-10000-34416	735 S FIGUEROA ST Suite 105	90017	14	129A207   336	4226001902	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	04/20/2015 12:00:00 AM	ADDRESS	34.04878	-118.26079	First time tenant to commercial retail space.  Plan check for energy under 2008 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69626	16041-10000-27932	2423 1/2 E MALABAR ST	90033	14	130-5A225 327	5177021019	R3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2037.10	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.0501	-118.20475	PV, INSTALL 2.6 KW DC ROOF-MOUNTED SOLAR ARRAY on a single family house.(10) modules: canadian solar csp6p-260(1) inverter: solaredge SE3000A-US	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69627	18041-20001-27329	8620 N TAMARACK AVE	91352	6	195B169   430	2631018079	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	Commercial			02/04/2019 12:00:00 AM			PC Approved	02/04/2019 12:00:00 AM	ADDRESS	34.2283	-118.38502	2/4/19changes to an approved set of plans.  changes to reflect field conditions.  this is plan check only.((((change of use from warehouse/office to hydroponic agricultural enterprise/office.  (E) 2000A 480Y/277V 3ph-4w and 400A 240/120V 1ph-3w services with new distribution.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69628	17041-20000-28179	11702 N MONTE LEON WAY	91326	12	213B121    62	2872007017	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.28417	-118.54764	Plan check for solar pv system, roof-mounted on SFD.8.96kW ungrounded system. (28) 320W ac modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69629	16041-20000-41375	20746 W DEARBORN ST	91311	12	198B109   154	2748037019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	08/08/2022 12:00:00 AM	ADDRESS	34.23706	-118.58582	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. CHANGE OF USE PORTION OF (E) MANUFACTURING TO ENLARGE AND REMODEL (E) VEHICLE REFABRICATING & RESTORATION /DEALERSHIP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69630	14041-20000-27566	14924 W HUBBARD ST	91342	7	216B149   619	2612023014	RS-1	North Valley	Sylmar	Sylmar		1066.49	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Expired	10/31/2016 12:00:00 AM	ADDRESS	34.28512	-118.45638	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 5kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(21) SolarEdge P300 power optimizers(21) Kyocera KD255GX-LFB3 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69631	16041-20000-30950	1400 S FIGUEROA ST	90015	14	126A205   122	5134009022	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			08/31/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Closed	09/15/2023 12:00:00 AM	ADDRESS	34.03868	-118.269	Plan check for power only. Temp power for construction of future apartment building. 800A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69632	11041-10000-06384	118 W 5TH ST	90013	14	129A211   134	5149036004	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.04707	-118.24933	UPDATING EMERGENCY LIGHTS AND SHOWING BASE BUILDING EMERGENCY ROOM PER INSPECTOR'S REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69633	19041-20000-28767	131 S LA BREA AVE unit 1	90036	5	138B181  1006	5513019010	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.07261	-118.34429	T24 PLAN CHECK FOR TI TO EXISTING RESTAURANT SPACE LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 892 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69634	16041-10000-22227	1901 S FIGUEROA ST	90007	9	124-5A205 194	5126003016	M1-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			06/23/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.0343	-118.27237	New Fire Alarm system on a new 4 level parking structure with a motor vehicle repair on the basement.  (2) F.A panels,  (209) F.A devices.  Building is located on methane zone.*Plan has been approved by the Fire Dept.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69635	10041-10000-23357	4209 S ALAMEDA ST	90058	9	114A215    82	5116024033	M2-2	South Los Angeles	2281.00	Central Alameda		2281.00	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.00559	-118.23945	New 6.5 kw PV system for a restarant.. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69636	19041-10001-29637	1132 N GLENDALE BLVD	90026	13	139-5A207 131	5404016022	C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM			PC Approved	08/21/2019 12:00:00 AM	ADDRESS	34.07702	-118.26071	***Expedite Fee*** NEW CARPORT MOUNTED 496KW PV SYSTEM WITH 1378 PV PANELS AND 8 CENTRAL INVERTERS AND A BATTERY SYSTEM. B#17016-10000-37519	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69637	15041-10000-29697	812 W 98TH ST	90044	8	093A199   269	6054005018	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	33.94694	-118.2898	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69638	15041-10000-38337	1430 W MIRAMAR ST	90026	13	133-5A207 232	5153028015	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Apartment			11/13/2015 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.05965	-118.2619	PC FOR POWER.  UPGRADING SERVICE FROM 400A TO 600A. CHANGING BREAKER TO EACH UNIT TO 60 AMPS, NO NEW LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69639	15041-20000-18239	4238 N ST CLAIR AVE	91604	2	165B165   793	2367006033	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	34.14789	-118.39968	Plan check for PV roof mounted sytem. System size 6.0kW  with 30 modules and 1 inverter (6.0kW) Standard Plan is being use	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69640	16041-20000-44971	418 N NORTH FARING ROAD	90077	5	141B157    12	4358007015	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2016 12:00:00 AM			Reviewed by Supervisor	01/25/2017 12:00:00 AM	ADDRESS	34.08616	-118.43257	Plan check for power. Addition to SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69641	10041-20000-05440	7325 N MEDICAL CENTER DR 202-204	91307	3	186B097   830	2021014040	(Q)CR-1VL, CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	09/22/2010 12:00:00 AM	ADDRESS	34.20328	-118.62963	PLAN CHECK POWER AND ENERGY FOR INTERIOR  TENANT IMPROVEMENT FOR 2ND FLOOR MEDICAL OFFICE . NOT CHECK FOR OSHPD III	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69642	12041-10000-02458	143 S LA BREA AVE	90036	5	138B181  1040	5513019009	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	02/02/2012 12:00:00 AM	ADDRESS	34.07233	-118.34423	T.I. to an existing restaurant.  Lighting change, new circuits and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69643	19041-10000-06967	2746 S ORANGE DR	90016	10	123B177  1634	5049015004	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.02969	-118.35418	PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 9 MODULES (REC290TP2) WITH A CENTRAL INVERTER (SOLIS-3K). SYSTEM SIZE IS 2.61KWdc AND 3KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69644	18041-10000-42035	1919 N VINEBURN AVE	90032	14	135A229    11	5215014005	[Q]CM-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Issued	11/02/2018 12:00:00 AM	ADDRESS	34.06533	-118.19012	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69645	18041-10000-29300	777 S FIGUEROA ST #3800	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.04828	-118.26116	PC FOR T-24 ENERGY ONLY FOR OFFICE TENANT IMPROVEMENT IN A HIGH RISE (38TH FLOOR). TOTAL AFFECTED AREA 9518 SQ.FT SCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS. B#18016-10000-23760	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69646	15041-20000-02673	2711 E OLYMPIC BLVD	90023	14	120A221    42	5170019016	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	04/21/2016 12:00:00 AM	ADDRESS	34.02434	-118.21942	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT.WSS  RETAIL SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69647	17041-10000-12885	18164 W ARMINTA ST	91335	12	189B125   549	2102017114	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Issued	04/20/2017 12:00:00 AM	ADDRESS	34.21373	-118.52954	Installation of new roof mounted solar PV array on existing single family dwelling.  AC module system.  Total system size = 8.96 kWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69648	14041-20000-08713	21255 W BURBANK BLVD 6TH FL.	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.17432	-118.59446	T.I. to existing high rise building partial of 6th floor.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69649	14041-10000-21741	4034 S CRENSHAW BLVD	90008	10	114B185   179	5033004035	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM			PC Approved	09/18/2014 12:00:00 AM	ADDRESS	34.01138	-118.33489	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR KRISPY KREME. CHANGE OUT LIGHT FIXTURES. PERMIT PREVIOUSLY PULLED UNDER 14041-10000-17840.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69650	18041-10000-34553	1213-1213 1/2 S SERRANO AVE	90006										Electrical	Electrical	Apartment			09/10/2018 12:00:00 AM			PC Approved	09/10/2018 12:00:00 AM	ADDRESS	34.04854	-118.30652	ADDING NEW PLUGS FOR AC UNITS IN TWELVE UNITS. PLAN CHECK FOR POWER ONLY.  PLAN CHECK REQUESTED PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69651	14041-20000-10560	2619 E 8TH ST UNIT C	90023	14	121-5A221  25	5170006007	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM			PC Approved	04/22/2014 12:00:00 AM	ADDRESS	34.0284	-118.2198	"PLAN CHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR WAREHOUSE. NO CHANGE IN OCCUPANCY. NEWLY CONNECTED LOAD < 400 AMPS. 1675 SQFT, EMERGENCY LIGHTING. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69652	18041-10000-27862	20221 W PRAIRIE ST	91311	12	198B113   119	2748038030	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	01/19/2024 12:00:00 AM	ADDRESS	34.23931	-118.57365	NOTE: Fees are $0 due to Assembly Bill 1414.Install Rofftop solar system in a Commercial Building, Build.-C.System size, 42.48 kWptc39kW DC/ 33kW AC. SCOPE INCLUDES (120) modules, (60) optimizers, (1) central string inverter, TO BE CONNECTED TO EXISITING SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69653	11041-20000-01840	555 W 5TH ST 14th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM	03/02/2011 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.05016	-118.25369	Plan check T24 energy and emergency lighting  plan check 14th floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69654	14041-10000-34546	1011 S SERRANO AVE 1-104	90006	10	129B193   356	5080014012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.0522	-118.3065	Plan check power and energy for new 104 units appartment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69655	17041-10000-19429	16380 W ROSCOE BLVD	91406	6	192B137   317	2689023001	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.22113	-118.48952	REPLACE HID FIXTURES FOR LED TYPE.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69656	19041-20000-53339	13120 W VAN NUYS BLVD	91331	7	210B161   728	2534018005	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.01	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	04/08/2021 12:00:00 AM		Issued	04/08/2021 12:00:00 AM	ADDRESS	34.26832	-118.4187	1200A 208Y/120V 3ph-4w service, distribution, and power for two commercial buildings.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69657	15041-20000-31356	1701 N GAFFEY ST	90731	15	024B197   211	7442023019	[Q]M1-1VL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Approved	10/13/2015 12:00:00 AM	ADDRESS	33.76094	-118.29308	Plan check for Title 24 only. Project site is an existing commercial building (Target). Project scope is a tenant improvement. Total lighting area = 99,030 sq. ft.Note: Building permit has been filed under 15016-40000-20224	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69658	14041-10001-03081	4917 N FORMAN AVE	91601	4	168B177   265	2420015007	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.15966	-118.35305	Expedited RSES plan check per applicant request.{{PV1, Install 5.75 KW DC roof-mounted solar array on a 1-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(23) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69659	18041-20000-35639	2917 W TEMPLE ST	90026	13	139-5A203 445	5156014010	RAS3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Rampart Village	YES	1958.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.07449	-118.27896	Plan check for a PV2 roof-mounted PV system. System size is 21.08 kWdc/20 kWac and consists of (2) inverters, (62) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69660	11041-20000-23720	6425 W HOLLYWOOD BLVD #17 & #18	90028	13	148-5A187  96	5546006019	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM	11/04/2011 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.10176	-118.33039	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69661	11041-10000-05617	7133 W HAWTHORN AVE	90046	4	147B181   345	5548008014	R3-1	Central	Hollywood	Hollywood Hills West		1899.01	Electrical	Electrical	Apartment			03/22/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.09988	-118.34596	NEW 3 STORY 19 UNITS APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69662	10041-10000-18103	2466 S CORINTH AVE	90064	11	123B153   449	4260040023	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Apartment			09/13/2010 12:00:00 AM	09/13/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	34.03318	-118.43822	Fire alarm system for 8 unit 3 story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69663	15041-20000-15685	1369 N LONDONDERRY PL	90069	4	144B169    52	5559010004	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM	02/09/2016 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.09483	-118.38034	Plan check for power only.  New single family dwelling with 800 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69664	10041-10000-15123	16500 W VENTURA BLVD	91436	5	168B137   382	2284005036	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Public Safety Only			08/04/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	08/10/2010 12:00:00 AM	ADDRESS	34.15743	-118.49262	REPLACE FIRE ALARM PANEL AND ADD NEW POWER SUPPLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69665	14041-20001-26853	5138 N LOUISE AVE	91316	5	171B133   398	2258009020	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.16443	-118.50966	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 3.6KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. LOAD CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69666	18041-20000-25209	925 W 34TH ST 1st Floor	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/30/2018 12:00:00 AM		Issued	07/30/2018 12:00:00 AM	PIN	34.02383917	-118.28572873	Renovation of (E) restrooms in commercial building adjacent to center east lobby.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69667	11041-10000-08310	8706 W 3RD ST	90048	5	138B169   562	4334011008	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/25/2011 12:00:00 AM	04/25/2011 12:00:00 AM		Permit Finaled	05/13/2011 12:00:00 AM	ADDRESS	34.0734	-118.38211	EXISTING RESTAURANT.  ADDING 5 NEW LIGHTING FIXTURES TO THE PATIO AREA.  TITEL 24 PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69668	15041-10001-37855	189 S THE GROVE DR G-60	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM			PC Approved	01/05/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	Supplemental changes on approved set: added receptacles, revised EM lighting layout, revised lighting control schematic, updated lighting specs. and panel schedule, updated T-24 form, added photometric sheet. ***T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (VINCE STORE ). SCOPE INCLUDES NEW LIGHTING, TWO NEW PANELS, AND ONE TRANSFORMER. TOTAL AREA IS 2439 SQ. FT.***	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69669	15041-20000-28266	22701 W DOLOROSA ST	91367	3	174B097   773	2040019010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2015 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.17024	-118.62132	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (35) modules, and (1) load center. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69670	13041-10000-36140	13271 N HERRICK AVE	91342	7	225B145   280	2501009006	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Finaled	03/04/2014 12:00:00 AM	ADDRESS	34.31209	-118.46223	PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 200A MAIN IN A 1-STORY HOME. non-standard plan. SYSTEM SIZE IS 3.75 kW DC, & transformerless, with power  optimizers   (15) Trina solar #TSM-250PA05.18(1) Solaredge #SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69671	14041-20000-22116	633 W 5TH ST 8TH FLR	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	08/20/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.05099	-118.25468	TI TO AN EXISTING HIGH RISE BUILDING TITLE 24 ENERGY AND EMERGENCY ONLY. NEW LIGHT FIXTURES AND NEW BRANCH CIRCUITS.  NO NEW PANELS.  WORK TO BE DONE ON THE 8TH FLOOR. 3000SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69672	16041-10000-27180	6500 W WILSHIRE BLVD 16TH FLR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.06371	-118.3703	T-24, PC FOR ENERGY ONLY TI TO AN EXISING COMMERCIAL BUILDING ON THE 16TH FLOOR (SUITE 1650). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 6161 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69673	16041-10000-33345	11725 W SUNSET BLVD	90049	11	135B145   578	4402009016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM			PC Info Complete	12/08/2016 12:00:00 AM	ADDRESS	34.06488	-118.47066	FULL PAN CHECK FOR POWER AND ENERGY FOR NEW MULTIPURPOSE FACILITY WITH ATHLETIC FIELD. TOTAL TITLE 24 SQ. FT. 131984 SEVICE SIZE 1600A - 480/277.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69674	17041-10000-36726	929 W JEFFERSON BLVD 1610	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/12/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.02454	-118.28546	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT FOR A NEW RESTUARANT WITHING AN EXISTING CORE AND SHELL BUILDING. SCOPE INCLUDES ONE NEW 225A PANEL, NEW CIRCUITS, AND LIGHTS. TOTAL AFFECTED AREA IS 658 SQ. FT. B#17016-10000-28900	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69675	14041-20000-27602	11100 W SANTA MONICA BLVD 16th floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI for 16th floor board room and adjacent office spaces/support areas.  Plan check for lighting - Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69676	16041-10000-11602	10201 W PICO BLVD B89	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM			PC Info Complete	04/04/2016 12:00:00 AM	PIN	34.05182951	-118.41257696	TENANT IMPROVEMENT TO (E) COMMERCIAL BUILD. 3RD FLOOR. SCOPE INCLUDE: RESTROOMS, PANTRY, AND VENDING AREA.  PC FOR T-24 ONLY, TOTAL AREA: 882 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69677	16041-20000-14646	16540-16542 W ARMINTA ST	91406	6	189B137    46	2205009046	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	06/08/2017 12:00:00 AM	ADDRESS	34.21472	-118.4936	PERMIT FEE $0.00 STATE SENATE BILL NO. 1222Plan check for a PV2 roof-mounted PV Feed-In Tariff system. System size is 42.7 kWac and consists of (2) inverters, (175) modules, (1) load center, and (1) transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69678	14041-20000-32454	8521 N FALLBROOK AVE 2ND FLR	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.22368	-118.62797	NEW LIGHITNG DESIGN IN COMMON AREA OF 2ND FLOOR. WORK DONE IN CORRIDOR, ELEVATOR LOBBY,  AND RESTROOMS. DUE TO BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 ENERGY EFFICIENCY STADARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69679	14041-20000-00775	1701 S BUCKINGHAM ROAD	90019	10	126B185   334	5071010024	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.04361	-118.33444	Modification to previously approved plans on #13041-2000033624 to correct site plan to reflect actual conditions.       <<<Installation of Solar System 8.32kw for an existing single family dwelling.  Enphase M215 microinverters.>>>	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69680	13041-10001-29534	18789 W WILLOWTREE LANE	91326	12	207B121   527	2728029074	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.26304	-118.54276	Expedited RSES plan check per applicant request.((((PV1.  Install 8.25 kW DC roof-mounted solar array, interconnect with main service panel.  Inverter: (Fronius IG Plus V 7.5.  33 modules: Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69681	14041-20000-30836	900 N CAHUENGA BLVD 4001-4002	90038	13	144B185  1190	5533019012	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.0873	-118.32862	TI TO AN EXISTING HIGH RISE BUILDING.  ADDING LIGHTING FIXTURES TO TWO RESTROOMS NUMBERED 4001 AND 4002.  541 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69682	13041-10000-34540	1438 N GOWER ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.09714	-118.32212	PLAN CHECK FOR POWER. TENANT IMPROVEMENT. UPGRADE OF SERVICE. CONVERTING TWO SERVICES( 400 AMP SINGLE PHASE AND 800 AMP 3PHASE ) TO ONE ( 1000AMP 480V ). BUILDING 35.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69683	16041-10002-20082	3000 S ROBERTSON BLVD 200	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM			PC Approved	10/11/2016 12:00:00 AM	ADDRESS	34.03242	-118.39001	Changes to approved set. Changing type of light fixtures under delta 1. (((( T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING KAISER NATIONAL FACILITIES SERVICES (NFS) DEPT; NEW OFFICE AND MEETING SPACES WITH NEW RECEPTION. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 4018 SQ. FT. )))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69684	14041-20001-00055	6960 N RUBIO AVE	91406	6	183B137   280	2225006034	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.19729	-118.49548	(((EXPEDITE))PV1 SINGLE FAMILY DWELLING. TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL SYSTEM SIZE 6KW AC USING 28 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69685	12041-10000-26886	17337 W LASSEN ST	91325	12	201B129    55	2734031019	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM			PC Info Complete	01/23/2013 12:00:00 AM	ADDRESS	34.25052	-118.51258	8.40 kw roof mounted PV for a single family using x-formerless INV. (PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69686	16041-10001-42197	1334 S HAUSER BLVD	90019	10	129B177   660	5085032020	R2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	34.05022	-118.35601	Expedited fees. PV2 roof mounted solar system instalation to commercial property. Installing 3.0 KW central inverter being fed by 15 solar modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69687	09041-10003-16655	5927 N LANKERSHIM BLVD	91601	2	177B169   982	2338009003	RD2-1, [T][Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	Public Safety Only			06/23/2010 12:00:00 AM			PC Approved	06/23/2010 12:00:00 AM	ADDRESS	34.17837	-118.38308	AS-BUILT SETS OF PLANS FOR A NEW FIRE WARNING SYSTEM FOR A 2-STORIES COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69688	17041-10000-15306	10250 W SANTA MONICA BLVD #1955	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""JOURNELLE"" Ste. #1955.  Total area: 1143 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69689	18041-10001-12956	2917 W VERNON AVE	90008	10	111B189   172	5023016026	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM			PC Approved	05/24/2018 12:00:00 AM	ADDRESS	34.00381	-118.32531	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE(CONSULTATION). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 570 SQ. FT. B#18016-70000-03151NOTE: PERMIT IS PAID UNDER PCIS#18041-70000-12956	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69690	14041-20002-27169	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM			PC Approved	06/19/2019 12:00:00 AM	ADDRESS	34.04342	-118.25478	Revision to approved set of plans.  Approval for delta-13 revisions only addressing stairwell/fire escape EM egress lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69691	16041-30000-25344	300 S GRAND AVE Suite 3950	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	10/24/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for Title 24 only. Project site is the 39th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 5,910 sq. ft.Note: Building application has been generated under 16016-10000-16100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69692	17041-10000-14592	1819 N CAHUENGA BLVD	90028	13	150A187   303	5546001400	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.1045	-118.33027	PC FOR ENEGY ONLY. T.I. CHANGE OF USE FROM RETAIL TO A TAKE-OUT RESTAURANT. CONNECTED LOAD < 400 AMP. TOTAL AREA 672 SQ FT.     B # 17016-10000-10618	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69693	17041-20000-09569	13919 W VICTORY BLVD	91401	2	180B153  1066	2238024039	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Apartment			03/24/2017 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	06/16/2021 12:00:00 AM	ADDRESS	34.18684	-118.43635	Plan check for power and energy. Project site is a new 2-story, 18-unit apartment building. Work includes a new 1,000-amp service. Total lighting area = 17604-SQ FT.Note: Building permit has been pulled under 14010-20000-03114	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69694	14041-20001-14573	8118 N JUMILLA AVE	91306	3	189B117   130	2106014018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2014 12:00:00 AM			PC Approved	07/18/2014 12:00:00 AM	ADDRESS	34.21736	-118.56324	((expedite fees)))((new system design. total size 6kw ac using transformerless inverter. using power optimizers. deregard original permit. may refer to original for zoning clearances. 13041-10000-33150	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69695	16041-20001-03720	11439 N RUBIO AVE	91344	12	213B137   662	2682002013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	34.27845	-118.49699	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. PV system is a 3 kWac addition to an existing 5 kWac system, for a total system size of 8 kWac. PV addition consists of (1) inverter, (13) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69696	17041-20000-22682	3530 W WILSHIRE BLVD	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	01/09/2018 12:00:00 AM		Issued	01/09/2018 12:00:00 AM	ADDRESS	34.06154	-118.30122	Plan check for a PV2 roof-mounted PV system. System size is 300 kWac and consists of (5) inverters, (1,054) modules, and (1) load center on parking structure. Note: Permit Fees $0 Due to SB 1222 Note: Building application has been generated under 17014-30000-03172	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69697	19041-10000-12085	11777 W SAN VICENTE BLVD	90049	11	129B145    59	4401017026	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/03/2020 12:00:00 AM	ADDRESS	34.05331	-118.46832	T-24, PC FOR ENERGY ONLY FOR A RESTUARANT. TOTAL AFFECTED AREA IS 4100 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69698	15041-20000-23265	19954 W LEMARSH ST	91311	12	204B113   350	2726023008	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.25533	-118.56849	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel.(31) Kyocera KU 2656 Modules(1) Fronius Primo 7.6 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69699	16041-10000-19229	360 E 2ND ST 2-8	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.04805	-118.24012	CORE AND SHELL WORK. UPGRADE RESTROOMS AND UPGRADE AC UNITS. NEW LIGHTING AND MINOR POWER. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69700	16041-20001-13824	2033 S VICTORIA AVE	90016	10	126B185  1307	5061001014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2187.01	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM			PC Approved	04/29/2016 12:00:00 AM	ADDRESS	34.03739	-118.33404	Revisions to approved plans showing derating of main breaker (center-fed panel).  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69701	16041-20001-29548	10831 W CROCKETT ST	91352	2	192B177   712	2407024029	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.22038	-118.36623	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE:  3.92 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69702	15041-10000-06766	1050 S GRAND AVE	90015	14	127-5A207 294	5139010003	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Closed	10/04/2017 12:00:00 AM	ADDRESS	34.04171	-118.26155	TEMPORARY POWER FOR CONSTRUCTION OF NEW HIGH RISE RESIDENTIAL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69703	17041-30000-04904	19333 W BUSINESS CENTER DR	91324	12	195B117    45	2783025084	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Closed	11/30/2017 12:00:00 AM	ADDRESS	34.23134	-118.55494	Plan check for a fire alarm system for a dialysis center. Fire alarm system consists of (1) FACP and (86) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69704	10041-10000-09449	1308 W 8TH ST	90017	1	130-5A205 325	5143001012	C2-2	Central	Westlake			2093.00	Electrical	Electrical	Public Safety Only			05/19/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	06/22/2010 12:00:00 AM	ADDRESS	34.05027	-118.26947	"Install a fire alarm system as a part of an ""Elevator Recall System"" in a 4 story building."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69705	11041-10000-24754	5200 W WILSHIRE BLVD	90036	4	132B181    30	5507024010	[T][Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Closed	03/16/2012 12:00:00 AM	ADDRESS	34.06194	-118.3435	TEMPORARY 1200A CONSTRUCTION POWER-SWBD; DISTRIBUTION PANELS;FEEDERS FOR 2 EA CRANES/MANLIFT / 2EA MODULAR TRAILERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69706	19041-20000-11087	1100 S CLARK DR	90035	5	132B169  1130	4332014***	R3-1-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	ADDRESS	34.05686	-118.38459	replacement of existing fire alarm panel and addition of three devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69707	11041-20000-05168	8937 N SAN FERNANDO ROAD	91352	6	195B169   259	2631017051	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	07/11/2013 12:00:00 AM	ADDRESS	34.23104	-118.3853	PLAN CHECK POWER FOR NEW SERVICE UPGRADE TO 800A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69708	17041-10000-38632	2111 N GRIFFIN AVE	90031	1	136-5A223  28	5204018006	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM	02/20/2018 12:00:00 AM		Issued	02/20/2018 12:00:00 AM	ADDRESS	34.06975	-118.21183	FULL PC FOR A NEW GYMNASIUM TO AN EXISTING HIGH SCHOOL, WITH FULL KITCHEN AND STAGE PLATFORM. OCC. LOAD > 100. NEW 1600 AMP SERVICE FOR THE SCHOOL, PANELS FEEDING THE CLASSROOMS WILL BE EXISTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69709	13041-10000-04041	348 S RENNIE AVE	90291	11	111B141   473	4240010026	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	07/08/2013 12:00:00 AM	ADDRESS	33.99746	-118.47189	PV1 2 STORY HOUSE.  2.4KW INSTALLATION.  {10 MODULES: TRINA SOLAR TSM-240PA05} {TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69710	16041-20001-09655	712 S OLIVE ST Floors 1-7	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM			PC Approved	09/17/2018 12:00:00 AM	ADDRESS	34.0462	-118.25568	06/12/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 17. Changes throughout the plan set. There has been a removal of distribution equipment and previously approved loads have been recircuited.*****Previous Work Description*****Plan check for power and energy. Project site is an existing commercial building. Project scope is a core and shell/complete remodel of the interior of the building. All tenant improvements are future. Electrical system is completely new, along with a new service from LADWP. Total lighting area = 49,577 sq. ft.Note: Building permits have been pulled under 16016-10000-01621/01615/01618/01619.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69711	19041-10000-12803	16123 W CHATSWORTH ST	91344	12	207B141   337	2667027011	RE9-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	34.2648	-118.4835	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69712	16041-20000-26657	9132 N DE GARMO AVE	91352	6	198B173   154	2408034047	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM			PC Info Complete	10/26/2016 12:00:00 AM	ADDRESS	34.23512	-118.3746	Plan check for power only install 600HP wood grinder, 100HP hydraulic system and 2000A distribution and associated panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69713	12041-10000-23578	3904 S EAST BLVD	90066	11	114B157  1208	4214016027	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	03/22/2013 12:00:00 AM	ADDRESS	34.00615	-118.42428	FOR A SFD, ROOF-MOUNTED 3.43KW  PHOTOVOLTAIC SYSTEM USING MICEO-INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69714	15041-20002-28266	22701 W DOLOROSA ST	91367	3	174B097   773	2040019010	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.17024	-118.62132	09/29/2015 Changes to an approved set of plans. One of the 5 kWac inverter has been changed for a 6 kWac inverter. Total system size is now 11 kWac. No other changes were made. All changes have been clouded.*****Previous Work Description*****Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (35) modules, and (1) load center. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69715	18041-10000-30140	6621 W 86TH PL	90045	11	096B165   599	4122014023	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Apartment			08/09/2018 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	33.9594	-118.40536	PC FOR T24 ENERGY ONLY FOR APARTMENT COMMON STAIRWELL AND OUTDOOR LIGHTS. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 3944 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69716	14041-20001-05232	5833 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	33.97367	-118.41982	((EXPEDITE FEE)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69717	17041-10001-45126	15285 W SUNSET BLVD	90272	11	129B125   591	4423016007	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	09/10/2018 12:00:00 AM		Permit Finaled	04/01/2019 12:00:00 AM	ADDRESS	34.04704	-118.52517	Change to approved set by modifying the floor plan with new lighting and equipment. all changes under delta_L and K only.(((Full plan check for a first time tenant T.I . Scope includes new lighting and equipment with a new main 1200 Amp panel. Total area is 11,426 SQ FT.PER#17016-10000-37285)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69718	10041-10001-02019	117 E WINSTON ST	90013	14	129A213   226	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Apartment			04/03/2012 12:00:00 AM			PC Approved	04/06/2012 12:00:00 AM	ADDRESS	34.04713	-118.24718	As built drawing for previously approved set of plans.  Major change was new layout of equipment.  No change in number of circuits or equipment.  See existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69719	12041-10000-29876	3179 W LOS FELIZ BLVD	90039	13	156A205    18	5594019005	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.12375	-118.26848	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. SCOPE OF WORK IS  1916 SQ FT ON A RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69720	19041-10000-46452	13623 W BERG ST	91342	7	228B157   874	2510003006	R1-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			11/11/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.31843	-118.42958	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 9.38KWdc (10.08KWac) USING 28 VBHN335SA17 MODULES BY SANYO PANASONIC AND 14 CP-720 DUAL MODULE MICROINVERTERS. CONNECTED TO A 200Amp EXISTING SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69721	18041-20000-13035	8881 N KEWEN AVE	91352	6	195B165   410	2631030003	RS-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.23045	-118.39369	PC for 3.8kW(ac)/4.06kW(dc) rooftop solar for SFD. Adding seven new solar panels to existing solar system with seven panels (14 panels total). Installing new central inverter and adding optimizers to all solarpanels. Existing solar permit was pulled under 12041-20000-25646.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69722	19041-10000-02068	12320 W BRANFORD ST STE B	91352	6	201B165    82	2537020013	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	06/13/2020 12:00:00 AM	ADDRESS	34.24931	-118.40142	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69723	12041-10000-20404	118 W 4TH ST	90013	14	129A211    63	5149023013	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			PC Approved	08/29/2012 12:00:00 AM	ADDRESS	34.04845	-118.24802	Ti in an existing restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69724	15041-10000-21194	5601 N DE SOTO AVE 12-1-12-2	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/06/2015 12:00:00 AM	10/07/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"PC FOR ENERGY T24 ONLY. PC FOR NEW SINAGE TO HOSPITAL. SCOPE INCLUDES SIGN 12-1 AND 12-2.REFERENCE BUILDING PERMIT: 14048-10000-02685. PROPOSED 3'-9"" X 4'-10"" D/F ILLUM. POLE SIGN (9-0)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69725	09041-20001-07233	16422 W VENTURA BLVD	91436	5	168B137   401	2284002055	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM			PC Approved	04/12/2010 12:00:00 AM	ADDRESS	34.15707	-118.49064	Plan check only - Revisions to approved plans.  Indicated as Delta 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69726	16041-20000-09655	712 S OLIVE ST Floors 1-7	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	03/09/2021 12:00:00 AM	ADDRESS	34.0462	-118.25568	Plan check for power and energy. Project site is an existing commercial building. Project scope is a core and shell/complete remodel of the interior of the building. All tenant improvements are future. Electrical system is completely new, along with a new service from LADWP. Total lighting area = 49,577 sq. ft.Note: Building permits have been pulled under 16016-10000-01621/01615/01618/01619.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69727	19041-10000-19769	11419 W SANTA MONICA BLVD	90025	11	129B149   521	4261003019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04585	-118.45137	New (27) individual take out restaurants with a new 800Amp Service, Panels & Laods. Plan Check for Power & Energy.Building Permit: 19016-30000-08803	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69728	11041-10000-04081	3800 S AVALON BLVD BLDG 1	90011	9	115-5A207 134	5121007001	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	02/18/2015 12:00:00 AM	ADDRESS	34.01182	-118.26506	1000 AMP SERVICE UPGRADE.  5 EMPTY PANELS AND 1 PANELS WITH LOAD.  SINGLE STORY COMMERCIAL BLDG.  OTHER BUILDING ON SAME LOT WITH 400 AMP SERVICE UPGRADE WILL BE UNDER PCIS # 11041-10000-04083	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69729	11041-20000-12605	17061 W VENTURA BLVD	91316	5	168B133    27	2258013014	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/17/2011 12:00:00 AM	07/28/2011 12:00:00 AM		Permit Finaled	08/31/2011 12:00:00 AM	ADDRESS	34.16042	-118.50529	PLAN CHECK POWER AND ENERGY FOR CHG OF USE FROM BEAUTY SALON TO DENTAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69730	16041-20002-23116	11711 W PICO BLVD	90064	11	123B149   653	4260029033	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM			PC Approved	06/11/2018 12:00:00 AM	ADDRESS	34.03159	-118.44613	New plan design for lighting system for office/art studio remodel.  Plan check for energy. (((PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF ART STUDIO. 958 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69731	10041-20001-19509	1435 W 7TH ST	90732	15	015B193   410	7459001016	[Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM			PC Approved	07/05/2011 12:00:00 AM	ADDRESS	33.7377	-118.30896	Plan check for revision to approved plan.  Change point of connection from supply side to load side and derate main overcurrent protection device from 600A to 500A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69732	15041-10001-02172	7340 N KELVIN AVE	91306	3	186B109   811	2113014034	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM			PC Approved	02/19/2015 12:00:00 AM	ADDRESS	34.20394	-118.58615	Modifications to approved set.  Change of module layout on rooftop.Plan check fee is $0 per State Senate Bill SB1222.  (((PV1 standard plan with 6kw roof-mounted system including (20) Sunpower SPR-327NE modules and (1) Powerone PVI-6000 inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69733	15041-10000-33252	380 WORLD WAY T-19	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	T-24, TI TO AN (E) RETAIL KIOSK IN LAX TOM BRADLEY INTERNATIONAL TERMINAL. SCOPE INCLUDES A NEW PRE FRABRICATED CANOPY WITH NEW LIGHITNG FIXTURES TYING INTO EXTISTING PANELS. TOTAL SQ. FT. 370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69734	15041-10000-34874	736 S LINCOLN BLVD	90291	11	111B145   892	4243030029	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM			PC Approved	10/19/2015 12:00:00 AM	ADDRESS	33.99949	-118.46363	ALTERATIONS IN AN ACUPUTUR OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69735	14041-10000-28010	11150 W SANTA MONICA BLVD SUITE 480	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.04704	-118.44563	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. 2408 SQFT, EMERGENCY LIGHITNG. SUITE 480.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69736	16041-10002-21959	9725 N TUNNEY AVE	91324	12	201B117   333	2761034004	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM			PC Approved	10/17/2016 12:00:00 AM	ADDRESS	34.24722	-118.55755	10/17/16Changes to an approved set of plans. All changes are clouded. Changes include actual bus rating for the main service, derating the main breaker, and providing load calculations. Changes to reflect what is on the field. Note: permit is paid under PCIS#16041-10000-21959((((((PV1(ACM) INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.8KW INTERCONNECTED WITH MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69737	19041-20001-10407	10701 W WALNUT DR	91040	7	201B177    95	2542014020	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.25009	-118.36265	Expediter per applicant requestPlan check for PV roof mounted system, System size: 11.52KW  with 36 PV Modules and 1 inverter(11.45KW).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69738	17041-20001-03492	13173 W PACIFIC PROMENADE	90094	11	102B157   256	4211020***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/30/2017 12:00:00 AM			PC Approved	03/30/2017 12:00:00 AM	ADDRESS	33.97178	-118.42635	3.30.2017 - Plan check per inspector request. Installing 30kVA inverter to feed existing emergency lighting system in apartment.======REPLACE 30KVA TRANSFORMER AND INSTALL 150AMP FEEDER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69739	15041-10000-15506	1144 S BROADWAY	90015	14	126A209   221	5139017010	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/20/2015 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.03859	-118.25963	for a vacant 3-stories building, new wiring and switchboard  for overhead  service.; conduits from switchboard are stubbed-out.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69740	11041-20000-16152	6442 N PLATT AVE	91307	12	180B093   512	2036024053	(Q)C1-1VL, (Q)C4-1VL, (T)(Q)C1-1VL, C1-1VL, C4-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.188	-118.64248	PLAN CHECK T24 ENERGY WEIGHT WATCHERS TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69741	13041-20000-29383	19300 W RINALDI ST SUITE O	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.27414	-118.55457	PLAN CHECK FOR FIRST TIME TENANT ON 800A SERVICE. 2400SQRFT. PLAN CHECK FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69742	16041-10001-11270	8370 N VANALDEN AVE	91324	12	192B121   559	2784020025	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM			PC Approved	05/19/2016 12:00:00 AM	ADDRESS	34.22247	-118.54905	05/19/16Changes to an approved set of plans. Changes include relocating PV electrical equipment on site layout. Scope includes relocating the AC disconnect, inverter, and performance meter.  NOTE: Inspector to verify Solar Ready Service Panel. Permit paid under PCIS#16041-10000-11270 ((((PV1 rooftop solar installation 10kW AC system on SFD.  (45) CS6P-265P      (1) SE10000A-US     SE P-300 is used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69743	15041-20000-20062	8216 N NESTLE AVE	91335	12	192B125   744	2102022015	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.21994	-118.53075	Plan check for PV roof mounted system. System size: 5kW with 22 modules and 1 inverter(5kW) Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69744	16041-20000-17074	8820 S BELLANCA AVE	90045	11	096B169   943	4125018009	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	33.95688	-118.38038	TI TO AN EXISTING COMERCIAL BUILDING.  REMOVE EXISTING HID FIXTURES ANS REPLACE WITH NEW LED FIXTURES.  TOTAL SQUARE FOOTAGE 18645.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69745	12041-20000-07642	6826 N KESTER AVE	91405	6	183B149   712	2219019001	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM			PC Approved	04/03/2012 12:00:00 AM	ADDRESS	34.1946	-118.45728	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69746	10041-10000-00362	8707 S WESTERN AVE	90047	8	096A193    26	6036011034	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			01/08/2010 12:00:00 AM			Corrections Issued	01/08/2010 12:00:00 AM	ADDRESS	33.95877	-118.3092	T-24 lighting plan check only for remodeled office space.  Optional electrical plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69747	18041-20000-10736	8415 N SYLVIA AVE	91324	12	192B117   455	2784015007	RS-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.22332	-118.55249	pv1install roof mounted pv system sized 4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69748	14041-10000-33140	6262 N VAN NUYS BLVD #C-F	91401	6	178-5A151 200	2240003907	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM			PC Approved	12/01/2014 12:00:00 AM	ADDRESS	34.18408	-118.44846	Plan check for T-24 only for T.I. The Cafe - Van Nuys Court House 340 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69749	13041-20000-02219	888 S FIGUEROA ST # 2100	90017	9	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM	01/29/2013 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.0465	-118.26225	Relocate some lighting and install a couple of luminaires.   T-24 lighting plan check for 2100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69750	16041-20000-38315	1147 N BROAD AVE	90744	15	033B205   636	7423007017	[Q]RD3-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Apartment			10/28/2016 12:00:00 AM			PC Info Complete	10/28/2016 12:00:00 AM	ADDRESS	33.78616	-118.26143	Plan check for power and energy. Project site is an existing apartment building. Project scope is replacement of electrical distribution equipment. Total lighting area = 3,200 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69751	17041-10000-26075	1451 W VENICE BLVD	90006	1	127-5A201 153	5056007039	CM-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.04422	-118.28552	TITLE 24 PLAN CHECK FOR REMOVAL OF (28) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA =9075 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69752	10041-20000-02986	818 N BROADWAY	90012	1	135A215   313	5408030025	C2-2	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			02/19/2010 12:00:00 AM	02/19/2010 12:00:00 AM		Permit Finaled	04/06/2010 12:00:00 AM	PIN	34.06284793	-118.23753985	REPAIR FIRE DAMAGED SUSPENDED CEILING & LIGHTS.  REPLACE DRYWALL IN ( E) RETAIL UNIT # 109.ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69753	19041-10000-21592	7301 N TOPANGA CANYON BLVD	91303	3	186B101   880	2023006031	[Q]CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.20301	-118.60617	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69754	19041-10000-38970	13821 N KISMET AVE	91342	7	228B153   665	2503021057	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.3228	-118.43597	Plan check for a 5.0KW AC / 6.0KW DC PV1 roof mounted system. Scope includes (1) inverter and (18) modules interconnecting through the main service panal.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69755	19041-10000-10676	2108 W BRANDEN ST	90026	13	144A209   324	5423005015	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1974.20	Electrical	Electrical	Apartment			03/27/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Issued	09/25/2019 12:00:00 AM	ADDRESS	34.0871	-118.25804	***fee estimate***POWER AND ENERGY PLAN CHECK FOR A NEW APARTMENT COMPLEX OVER FIRST FLOOR GARAGE WITH PRIVATE ROOF DECK. SCOPE INCLUDES NEW 600A SERVICE, EQUIPMENT AND LIGHTING. TOTAL AFFECTED AREA IS 8327 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69756	17041-20002-38120	2351 N ACHILLES DR	90046	4	153B173   795	5569007056	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.11347	-118.36716	CHANGES TO APPROVED SET. CHANGES INCLUDE REMOVING EV OUTLET AND CHANGES TO CONDUCTOR SIZE. <<<Plan check for AC coupled battery backup system for SFD.Existing solar system on site.(2) Tesla Powerwall 2s.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69757	19041-20001-09203	1443 N FULLER AVE ev2	90046	4	147B181   757	5550018025	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	34.09721	-118.34969	09-25-2019 Changes to an approved set of plan Changes include revised load calculation and fault current calculation, remove disconnect and meeter. All changes has been clouded and apply to delta 1 only. Plan check only.Note to inspector: Please verify feeder length to be 65 feet for EV panel. Feeder length less than 65 feet, EV panel shall be rated for 22K AIC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69758	14041-10000-23359	210 N SAN PASCUAL AVE	90042	14	153A233   145	5493029022	RD2-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.11448	-118.17745	4.08KW PV1 roof-mounted system including (16) Kyocera KD255 modules and a Power One Aurora PVI 3.6-OUTD inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69759	16041-20000-39158	3230 S MAPLEWOOD AVE	90066	11	114B149   269	4247007007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.01052	-118.45201	pv1install roof mounted pv system (ACM) sized 18.2kw interconnected with msp.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69760	12041-10000-09686	823 W EXPOSITION BLVD	90089	8	117B197   224	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	08/21/2012 12:00:00 AM	ADDRESS	34.01842	-118.28748	NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69761	17041-20000-38935	16188 W ROYAL OAK ROAD	91436	5	162B141   272	2286013015	RE15-1-H	South Valley	Encino - Tarzana	Encino	Yes	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.13958	-118.48337	Plan check for the addition of a battery back-up system to an existing roof-mounted PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69762	14041-10000-16410	5527-5531 W HOLLYWOOD BLVD	90028	13	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	09/18/2014 12:00:00 AM	ADDRESS	34.10188	-118.31024	Permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A with emergency lighting. BLDG#13016 10 16974: CONSTRUCT A NEW EXIT CORRIDOR IN RETAIL PART OF RETAIL/HOTEL/APARTMENT.  NEW EXTERIOR DOOR OPENING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69763	10041-20000-09588	1864 N VERMONT AVE	90027	4	150B197   931	5590015003	C4-1D	Central	Hollywood	Greater Griffith Park		1891.00	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	05/20/2010 12:00:00 AM		Permit Finaled	12/15/2010 12:00:00 AM	ADDRESS	34.10489	-118.29162	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69764	13041-10000-09842	2130 S SAWTELLE BLVD 111	90025	11	126B153   959	4260001031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM			PC Approved	04/16/2013 12:00:00 AM	ADDRESS	34.03882	-118.4416	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. CHANGE OF USE FROM RETAIL TO RESTAURANT, LOAD IS LESS THAN 400 AMPS, OCCUPANT LOAD IS 48 ACCORDING TO 12016-10000-25931.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69765	17041-10000-36003	5811 S BROADWAY	90003	9	108B201  1346	5101040006	M1-1	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			Reviewed by Supervisor	10/18/2017 12:00:00 AM	ADDRESS	33.9895	-118.27848	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP(FEED IN TARIFF). TOTAL SYSTEM SIZE IS 128KWac. (424)MODULES-Q.CELLS Q.PEAK-G4.1 300(2)INVERTERS-YASKAWA PV1 28TL(2)INVERTERS-YASKAWA PVI 36TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69766	16041-30000-20838	3383 N CANTON WAY	91604	2	159B169   273	2377017029	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.13362	-118.38527	Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (2) inverters, (59) modules, (2) combiner boxes, and (1) load center.Note: Fee $0 DUE TO SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69767	13041-10000-11312	19602 W GIFFORD ST	91335	3	186B117   593	2116003075	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	34.20506	-118.56007	pv1 single family dwelling. total system size 3.8 kw. using transformerless inverter nonstandard plan. using 18 modules and power optimizers. pc for pv system. upgrade main service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69768	18041-10000-18479	5745 N LANKERSHIM BLVD	91601	2	174B169   411	2338023001	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	06/21/2018 12:00:00 AM	ADDRESS	34.1752	-118.38113	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69769	19041-20000-11499	17200 W VENTURA BLVD Ste # 305	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.16035	-118.50769	Change of use from retail to beauty parlor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69770	16041-10000-44588	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	34.23342	-118.3809	PC FOR POWER. INSTALLATION OF COMPRESSED NATURAL GAS COMPRESSION AND FUELING DISTRIBUTION SYSTEM. SERVICE UPGRADE 3000A. HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69771	18041-10000-39090	937 S CRENSHAW BLVD	90019	4	132B189   975	5090034011	CR-1VL	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.05538	-118.3228	PC FOR NEW OFFICE TI FOR NEW 2 STORY OFFICE. TOTAL CONNECTED LOAD <400ASCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 2840 IN /5895 OUT. B# 18010-10000-04388	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69772	12041-10000-27087	6256 N BLUEBELL AVE	91606	2	177B161   164	2332009021	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2012 12:00:00 AM	11/09/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.18465	-118.41014	PV1 SOLAR INSTALLATION 3.43KW. ENPHASE MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69773	19041-20000-46470	15136 W STAGG ST	91405	6	189B145   587	2209033053	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	09/10/2020 12:00:00 AM	ADDRESS	34.21197	-118.46321	New 800A 240/120V 3ph-4w service, distribution, power, and lighting. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69774	15041-10000-18365	11950 W LOPEZ CANYON ROAD	91342	7	216B165    24	2526003909	OS-1XL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	Commercial			06/12/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.28787	-118.40055	AT THE LOPEZ CANYON LANDFILL, INSTALLATION OF  5KV/35KV EQUIPMENT TO TRANSMIT POWER FROM ONE OF TWO GENERATORS (USING GAS FROM LAND FILL) TO EQUIPMENT WHICH TRANSFER POWER TO LADWP GRID:	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69775	18041-20000-24822	5757 W WILSHIRE BLVD #P2	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for power and energy for outpatient medical office space with operating room. Total area: 1827 sq ft. Modification filed to complete 30-day existing demand reading and resubmit to plan check. Building permit filed under 18016-20000-19914.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69776	18041-20000-32520	2591 S MILITARY AVE	90064	5	123B157   471	4256022019	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Expired	09/15/2023 12:00:00 AM	ADDRESS	34.0344	-118.43029	Plan check for PV roof mounted system size: 7.18 KW AC CEC with 23 pv modules and 23 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69777	15041-20000-29833	1055 W WILSHIRE BLVD Suite 1850	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	10/29/2015 12:00:00 AM	ADDRESS	34.05232	-118.2629	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 11,715 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69778	12041-10000-02632	1975 N CAHUENGA BLVD Suite# 110	90068	4	150A187    32	5575002001	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Commercial			02/03/2012 12:00:00 AM			PC Approved	02/03/2012 12:00:00 AM	ADDRESS	34.10721	-118.33086	TI IN UNIT # 110. PLAN CHECK FOR POWER & ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69779	15041-10007-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/18/2017 12:00:00 AM			PC Approved	12/18/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	Changes to an approved set of plans, Note changes on delta 19. Changes include the addition of 4 circuits to two panels.  ////////////////////Bulletin # 18 revisions :  UPDATED SPOT LIGHTING FOR LEV 8 FOOD HALL;UPDATED CONDUIT PENETRATIONS FOR LEV 7 BOH  AND LEV 8 ROOF/TERRACE AND RESTAURANT SHELL AND LEV 8 ELECTRICAL ROOMS 8A-2&3; UPDATED LIGHTING FIXTURE SCHEDULE.ALL CHANGES ARE CLOUDED AND IDENTIFIED.((((((((((PC FOR POWER AND ENERGY. NEW DISTRIBUTION EQUIPMENT FOR FUTURE TENANTS. MALL IS GUTTING AND RENOVATING 8TH FLOOR FOOD HALL. ASSOCIATED HOUSE LOADS AND EQUIPMENT INSTALLED AT THIS TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69780	11041-20000-22725	22212 W VENTURA BLVD	91364	3	171B101   118	2075001032	QCR-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM			PC Approved	10/26/2011 12:00:00 AM	ADDRESS	34.16847	-118.61095	Adding new parking lot light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69781	17041-10000-00208	10946 W MCBROOM ST	91040	7	207B173    92	2542001010	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2017 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.26132	-118.36871	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.2KWac.(38)MODULES-AXIPOWER AC-265P/156(1)INVERTER-FRONIUS PRIMO 8.2	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69782	19041-10000-29787	23366 W SATICOY ST	91304	12	189B093   703	2027001048	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.21077	-118.63635	[EPLAN]PLAN CHECK FOR ROOF MOUTED 15.2KVA PV1 SYSTEM CONSISTING OF 2 CENTRAL INVERTER(SE7600H-US) WITH 50 PANELS USING P320 OPTIMIZERS. $0 permit fees due to Senate Bill 1222. MAIN PANEL UPGRADE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69783	17041-20003-23935	21051 W SUPERIOR ST	91311	12	201B105   175	2746003003	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.24647	-118.59228	10.24.2017 - Plan check for changes to approved set. Update spec sheets for racking system, update elevation detail on sheet S1. Change windowed AC disconnect to 200A. Changes clouded.======09/28/2017 Changes to an approved set of plans. PV system size has increased to 22.8 kWac and consits of (3) inverters. Module count has not changed.Note: No change was made to the PV module layout and as such, LAFD layout approval is not required once again. *****Previous Work Description*****EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on commercial building.22.8kW ungrounded system. (66) 345W pv modules.Each module has a 400W power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69784	19041-10000-18727	6900 N WHITSETT AVE	91605	2	183B165   316	2324035901	OS-1XL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.04	Electrical	Electrical	Commercial			05/17/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	08/19/2020 12:00:00 AM	ADDRESS	34.1957	-118.40506	Full plan check for a public park. Scope includes new service, equipment and lighting with total lighting area of 94,755.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69785	12041-20000-15451	7040 N BIANCA AVE	91406	6	183B129   390	2228028023	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.19864	-118.513	solar system single family enphase	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69786	17041-10004-12815	384 WORLD WAY MSC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	33.94339	-118.40887	CHANGES TO APPROVED SET OF PLANS - CHANGES ARE NOTED UNDER DCN MSC-116 - SCOPE INCLUDES ADDING NEW PANELS, MODIFYING POWER AND LIGHTING CIRCUIITS, AND ADDITION AND REMOVAL OF EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69787	14041-20000-19118	3300 W WILSHIRE BLVD	90010	10	132B197    45	5094007020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM			Reviewed by Supervisor	09/16/2014 12:00:00 AM	ADDRESS	34.06161	-118.29461	PC FOR NEW SERVICE. 1600A. EXISTING CHURCH. RECONNECT TO EXISTING PANELS. POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69788	15041-10000-39947	4375 N KRAFT AVE	91604	2	165B169   360	2365016008	RD2-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	01/16/2016 12:00:00 AM	ADDRESS	34.14948	-118.38021	PV1 6.0KW roof-mounted system with (21) Canadian Solar CS6X-315 modulea and (1) Fronius Primo 6.0-1 inverter interconnecting through the main service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69789	13041-10000-14640	8385 N LAUREL CANYON BLVD	91352	6	192B165   367	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			06/05/2013 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.2231	-118.39669	Retail TI for a Radio Shack in Canyon Plaza Shopping Center.  New lighting and power.  Newly connected load < 400A, title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69790	17041-20000-07001	7202 W MELROSE AVE	90046	5	141B181   634	5525014027	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.08328	-118.3464	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 908 sq. ft.Note: Building application has been generated under 16016-20000-23621	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69791	12041-10000-18827	731 S OGDEN DR	90036	4	132B177    32	5086010031	[Q]C2-1-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/17/2012 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Closed	11/05/2014 12:00:00 AM	ADDRESS	34.06179	-118.36001	"New 400 Amp service for future ""Exploratory Shaft"" and parking lot lighting for a future underground METRO Railway.  (Area is in a Methane Zone, Level V)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69792	17041-20000-01333	10244 N WOODLEY AVE	91343	12	204B141   390	2669007018	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.25673	-118.48466	permit fee $0.00 by state senate bill no. 1222Plan check for a PV1 roof-mounted PV system. System size is 12 kWac and consists of (48) modules, (24) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69793	10041-10000-11274	6816 S CRENSHAW BLVD	90043	8	102B185   547	4006025020	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.02	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM	06/24/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	33.97642	-118.33067	remodel of existing commercial buildingplan chk is for title 24  (interior and exterior lightings) and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69794	18041-10000-23014	2600 S VERMONT AVE	90007	8	123B197   900	5055005033	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.03252	-118.29135	PC FOR COFFEE SHOP T.I. INSIDE AN EXISITNG GROCERY STORE AND OUTDOOR LIGHTS IN WALKWAY  FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 1474 + 1802 SQ.FT (INDOOR+ OUTDOR)B#18016-10000-19683	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69795	19041-20001-38247	6239 N ORION AVE	91411	6	177B145   221	2242005003	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM			PC Approved	10/28/2019 12:00:00 AM	ADDRESS	34.18416	-118.47007	Plan check approval for design plan set.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69796	13041-10000-15573	632 S LANDFAIR AVE	90024	5	135B149   344	4363006008	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			06/13/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Finaled	08/11/2014 12:00:00 AM	ADDRESS	34.06666	-118.44875	New 144 device fire alarm system for 4 story apartment building, 16 units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69797	13041-10000-02684	15021 W BRIARHILL DR	91342	7	216B145   161	2611036028	R1-1	North Valley	Sylmar	Sylmar	YES	1066.05	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.2872	-118.45928	PV1 for 2 story house via microinvertors. System size 3.67KW. [Microinverter: Enphase Energy. Model number: M215-60-2LL-S22] and [Module: REC Model number: REC 245 PE]. 17 microinverters and modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69798	10041-10000-04694	8401 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			03/16/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.22253	-118.62558	Installation of a MV 2.5MW non-legally required stand-by generator WITH ASSOCIATED EQUIPMENT TO ENERGIZE A 5000A EXISTING SWITCHBOARD. ALL LOADS ARE EXISTING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69799	19041-10000-32965	8345 N CANOGA AVE	91304	3	192B105   544	2779022081	M2-1, MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.22139	-118.5977	Remove HID fixtures and replace wiyth new LED fixtures (Outdoor only) T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69800	17041-20000-35667	3055 W 5TH ST	90020	13	135A201    53	5077001016	R4-2	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.06535	-118.28598	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.44 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69801	19041-20001-12692	17531 W WEDDINGTON ST pv1	91316	5	171B129   102	2257004059	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM			PC Approved	04/19/2019 12:00:00 AM	ADDRESS	34.16687	-118.51544	expeditepv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69802	13041-10000-06856	1302 W 177TH ST BLDG D	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	PLAN CHECK FOR POWER AND ENERGY FOR A NEW 10-UNIT APARTMENT BUILDING (BUILDING D). MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69803	13041-20000-20016	12826 W TONOPAH ST	91331	6	195B161   453	2628016007	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.23211	-118.41235	New Enphase PV System on the rooftop of an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69804	18041-10000-08323	7438 W 80TH ST	90045	11	099B157   289	4114014020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	33.96365	-118.4276	Plan check forTestla battery back up system 13.5 kWh, connected to existing PV roof mounted system on a SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69805	19041-10000-49637	11611 W SAN VICENTE BLVD 10TH FLR	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	11/13/2020 12:00:00 AM	ADDRESS	34.0541	-118.46261	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING, POWER AND CONTROLS. TOTAL AFFECTED AREA IS 12,348 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69806	16041-20000-43085	830 S OLIVE ST	90014	14	127-5A209  95	5144018026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.0443	-118.25741	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 800 AMPS. METHANE ZONE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69807	13041-20000-31119	3003 W LEEWARD AVE 1-67	90005	1	132B197   281	5077017021	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Apartment			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.05885	-118.28935	T24 FOR EXISTING APARTMENT COMPLEX. SCOPE OF WORK IN CORRIDOOR AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69808	19041-10000-40812	4542 N FARMDALE AVE	91602	2	168B169   940	2365012004	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2019 12:00:00 AM	10/08/2019 12:00:00 AM		Issued	10/08/2019 12:00:00 AM	ADDRESS	34.15338	-118.38104	Plan check for a PV1 3.8KW AC / 4.65KW DC roofmounted system. Scope includes (1) iverter, (15) module and optimizer interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69809	16041-20000-19337	3518 S TROUSDALE PKWY 356/373	90089	9	120A201    86	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.02157	-118.28415	TI to (2) office spaces in (E) university building.  Plan check for energy - 1200 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69810	15041-10000-04007	5700 S HOOVER ST	90037	9	108B201  1167	5001018030	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Apartment			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	33.9904	-118.28692	New fire alarm system for 2-story philanthropic institution.  New FACP and 100 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69811	17041-20001-29172	9041 N LAUREL CANYON BLVD	91352	6	195B165   118	2629032001	[T][Q]RD2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM			PC Approved	09/18/2019 12:00:00 AM	ADDRESS	34.23351	-118.40574	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED DELTA ONE CHANGES ONLY. MINOR CHANGE TO SINGLE LINE ELECTRICAL CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69812	16041-10000-08253	18816 W SAN FERNANDO MISSION BLVD	91326	12	210B121   184	2717006013	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.2734	-118.54293	Permit fee $3.45 per state senate bill #1222PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND A LOAD CENTER. (46) MODULES, (1)INVERTER-7.7KW, AND (1) INVERTER-5KW. TOTAL SIZE IS 12.7 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69813	11041-10000-06389	3659 E OLYMPIC BLVD	90023	14	118-5A227 191	5191008011	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	34.01901	-118.19844	T.I.  NEW 590 SQFT.  TITLE 24 PLAN CHECK ONLY.  FULL PLAN CHECK MAY BE REQUIRED PER FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69814	16041-10003-07723	5227 N VINCENT AVE	90041	14			R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2016 12:00:00 AM			PC Approved	06/09/2016 12:00:00 AM	ADDRESS	34.14226	-118.20245	Plan check only as replacement of lost plan which approved  and permitted under # 16041-10002-07723<<Change to approved set: show underground trench for DC connection, revise inverters location, revise single line diagram. New Load Center.>>16041-10002-07723<PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (34) MODULES, (1)3.0 KW INVERTER AND (1) 7KW INVERTER. TOTAL SYSTEM SIZE IS 10KW.>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69815	16041-10000-40233	1604 S HI POINT ST	90035	10	129B173  1141	5068019002	R1-1-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.04763	-118.36965	Plan check for a new PV array on existing residential roof-top. Scope includes adding 6 panels to an existing PV system and replacing the inverter. Total system size: is 3.0kWac.(6)MODULES-KYOCERA#KU2656ZPA(1)INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69816	16041-10000-45129	5001 W RODEO ROAD PV	90016	10	120B181   948	5046013900	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			Reviewed by Supervisor	02/09/2017 12:00:00 AM	ADDRESS	34.02168	-118.35178	INSTALLATION OF 150 KW AC SOLAR ARRAY ON GYM ROOF BUILDING. CONNECTED TO 400A PANEL(333) MODULES: SUNTECH STP  (2) INVERTERS : SOLECTRIA 75KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69817	12041-20000-18992	6251 N BUFFALO AVE	91401	2	177B157   177	2330013002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM			Plans on Hold	08/17/2012 12:00:00 AM	ADDRESS	34.18466	-118.43025	Plan check for SFD PV system. Roof-mounted 9.555kW DC System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69818	19041-10000-36972	640 S CURSON AVE	90036	4	135B177   593	5508015008	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Apartment			09/16/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	03/08/2021 12:00:00 AM	ADDRESS	34.06349	-118.35446	PC for Fire Alarm system for New 21-story, 285 unit, Apartment with 2 levels of subterranean Parking. (3) panels, (14) control devices and (1096) device.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69819	16041-20000-32898	10740 W VENTURA BLVD	91604	2	162B177   355	2378003012	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			Reviewed by Supervisor	10/28/2016 12:00:00 AM	ADDRESS	34.13841	-118.3657	Plan check for power and energy. New 46 room, 4 story hotel. Ground-floor restaurant+bar, roof-top bar+pool, and 3rd floor patio+pool. Basement garage with vehicle lifts. 8 typ. rooms. 34,750sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69820	18041-20000-36934	1821 S MESA ST LOT 16	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	33.72745	-118.28616	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69821	12041-10000-11365	3250 W OLYMPIC BLVD #102	90006	10	129B193   288	5080009008	[Q]C2-2D	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	07/09/2012 12:00:00 AM		Permit Finaled	08/22/2012 12:00:00 AM	ADDRESS	34.05244	-118.30766	Change of use from restaurant to bakery.  181.6 amps of load, per applicant from a 3000A service.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69822	12041-10000-10012	15604 W ROYAL WOODS PL	91403	5	162B141   237	2280005011	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	09/18/2012 12:00:00 AM	ADDRESS	34.14044	-118.47257	New 11.445kw photovlotaic, rooftop, system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69823	12041-20000-04479	24569 W CALVERT ST	91367	3	177B085   125	2032010005	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	34.18324	-118.6605	pv system single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69824	11041-20000-09329	3663 W WILSHIRE BLVD Temple	90010	10	132B193    23	5503027016	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02, 2125.00	Electrical	Electrical	Commercial			05/09/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	34.06188	-118.30486	Plan check power and energy for historic temple, central plant, and service yard. New 3000A service supplying multiple buildings on the same property. Central Plant pemit under #11041-20000-25181and Service Yard permit under #11041-20000-25183. Variance to seperate new fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69825	14041-20000-01326	6522 N BELMAR AVE	91335	3	180B117   661	2131027003	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2014 12:00:00 AM	01/16/2014 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.18888	-118.55803	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN 2 STRINGS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69826	19041-10000-14037	10657 N RUSSETT AVE	91040	7	207B189   739	2555030010	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.26319	-118.31924	PC for PV system. system includes 28 modules(Sunpower SPR-X22-370-E-AC) W/microinverter. 1 Loadcenter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69827	12041-10000-20508	6862 N HAYVENHURST AVE	91406	6	183B137   380	2224019016	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.19561	-118.49221	Change of use to an entertianment hall.  Occupancy load is greater than 99, Place of Assembly.  New panels, loads, lighting.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69828	11041-10001-09154	3335 S FIGUEROA ST	90007	8	120A203   177	5123009027	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.02224	-118.28008	CHANGES TO PERMITTED SET OF PLANS-ADDED NEW PANELBOARD AND CIRCUITS AND REVISED THE LIGHTING SYSTEMRESTAURANT, FIRST TIME TENANT, IN A NEW MIXED USE BUILDING.  FULL PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69829	15041-10000-25399	700 S FLOWER ST 16th Flr	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	Energy plan check for an office T.I ; Scope includes new light, equipment and receptacles. Total area is 23,358-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69830	19041-20000-18125	20831 W PINECONE CIR 21	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.2959	-118.58798	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69831	12041-10001-02148	1200 S SANTEE ST 1ST FLR.	90015	14	124-5A209 102	5145027001	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM			PC Approved	03/15/2012 12:00:00 AM	ADDRESS	34.03607	-118.25735	Plan check T24 Energy for retail spaces, corridor, and outdoor canopy lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69832	19041-10000-02284	6361 W SANTA MONICA BLVD	90038	13	144B185   688	5533008011	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	08/24/2020 12:00:00 AM	ADDRESS	34.09087	-118.32815	PLAN CHECK FOR T-24 ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING IN ROOF AREA. TOTAL SQ. FT. 3517.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69833	19041-10000-01862	9650 N TOPANGA CANYON PL	91311	12	201B105   201	2746016***	(Q)MR1-1, MR1-1, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.24566	-118.60477	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69834	17041-10000-17278	41 E OZONE AVE	90291	11	111B141   730	4286018026	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.99605	-118.48001	Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  Two Tesla AC Powerwall 5.8 kW 13 kWH battery and ABB PV1.3 kWac inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69835	14041-20000-19966	18437 W SUPERIOR ST	91325	12	201B125   263	2764005024	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	07/28/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.24651	-118.53529	(2) new pole lights for lighting of parking lot adjacent to (E) church.  Plan check for energy. INSTALLING CONDUIT ONLY FOR FUTURE FIBER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69836	14041-10000-34302	9164 N JORDAN AVE	91311	12	198B105   150	2746012031	[T][Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.23732	-118.60379	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3536 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69837	17041-10002-44200	13832 W MULHOLLAND DR	90210	5	159B153   194	4385021023	RE20-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	34.13091	-118.43355	SUPPLIMENTAL PLAN CHECK ONLY FOR CHANGES TO AN APPROVED SET UNDER DELTA 1. CHANGES INCLUDE RELOCATION OF MODULES AND PANELS. DISTANCE FROM THE POOL IS SUBJECT TO FIELD INSPECTION.  SAME NUMBER OF MODULES PER PV CIRCUIT.SYSTEM SIZE IS 15.36KW(ac) ROOFTOP SOLARPERMIT IS ISSUED UNDER 18041-10000-44200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69838	13041-20000-08032	10960 W WILSHIRE BLVD #1000	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.058	-118.44597	Change to lighting in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69839	11041-10000-04358	6425 W WEIDLAKE DR	90068	4	154-5A187  16	5577033029	R1-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.11591	-118.32913	NEW 10,000 SQF  SFR.  600 AMP 3 PHASE SERVICE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69840	13041-10000-26742	1200 N STATE ST 1ST FLOOR	90033	14	133-5A223  79	5201001901	PF-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM			Reviewed by Supervisor	10/07/2013 12:00:00 AM	ADDRESS	34.0604	-118.20881	FIRE ALARM RENOVATION FOR A COMMERCIAL BUILDING. ADDING FIRE ALARM DEVICES TO AN EXISTING SYSTEM (FS90+). SPRINKLERED SYSTEM. MULTI-STORY BUILDING, ONLY FIRST FLOOR WILL BE RENOVATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69841	17041-10001-40086	411 E 120TH ST 1-8	90061	15	084B205  1139	6083029027	R3-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	33.92386	-118.26699	PC FOR REVISION TO APPROVED SET FOR CHANGES UNDER DELTA 2 ONLY. SCOPE INCLUDES CHANGES TO FEEDERS LENGTHS WITH VOLTAGE DROP AND FAULT VAULES RECALCULATED. THIS IS PLAN CHECK ONLY! PERMIT FEES PAID UNDER MASTER. Plan check for service upgrade to 600A  to feed 5 separate appartment Buildings. Main service at 411 E. 120th StreetVariances submitted for having multiple feeders supplying other buuildings	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69842	17041-10000-23610	3361 N ANDRITA ST LOT 5	90065	13	156B213   323	5458026014	RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2017 12:00:00 AM			Reviewed by Supervisor	07/24/2017 12:00:00 AM	ADDRESS	34.12022	-118.24066	POWER PLAN CHECK.  NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2-CAR GARAGE.  BUILDING 5 OF 10.  ALL 10 SFD BUILDINGS HAVE A COMMON 800 AMP 120/240 VOLT SERVICE.       BUILDING PERMIT #16010-10000-05787	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69843	17041-10001-15044	1051 S QUEEN ANNE PL	90019	10	132B185   753	5082001011	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM			PC Approved	10/04/2017 12:00:00 AM	ADDRESS	34.05558	-118.33003	supp. for OT PC FOR ROOF MOUNTED PV SYSTEM WITH AC CONNECTED BATTERY.SYSTEM SIZE 7.6 KWAC (SOLAR EDGE)TESLA  POWER WALL 1 BATTERY 3.3 KW (DC/DC)INCLUDING 8 MOUDULES WITH OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69844	15041-10000-18748	12457 W OSPREY LANE	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	33.97937	-118.41024	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'B'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'B' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69845	10041-20000-17637	21201 W KITTRIDGE ST	91303	3	180B105    29	2148030031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			09/07/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	01/03/2011 12:00:00 AM	ADDRESS	34.19131	-118.59428	add air handeling units in coridoors of 11 buildings and one panel for each building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69846	14041-20000-09812	338 S RENNIE AVE 3	90291	11	111B141   922	5018023056	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	33.99791	-118.47188	PV1.  Install 2.12 kW DC roof-mounted PV system, interconnect with main service panel.  (8) modules.  Microinverter standard plan - Enphase M215-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69847	18041-10000-35956	16850 W SAN FERNANDO MISSION BLVD ??	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.27109	-118.49964	FULL PLAN CHECK FOR - CHANGE OF USE FROM RETAIL TO DENTAL OFFICE. T.I. REMODEL AND RESTRIPING PARKING LOT. - TOTAL AFFECTED AREA = 2056 SF. WITH APPROX. 115A OF CONNECTED LOAD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69848	16041-10000-30268	610 S MAIN ST	90014	14	127-5A211  56	5148021015	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.04479	-118.25017	PC FOR POWER ONLY FOR AN EXISTING MULTIDWELLING BUILDING. SCOPE IS TO INSTALL WASHER AND DRYER CIRCUITS FOR 264 UNIT APARTMENT ON 2ND THROUGH 7TH FLOOR ((b#16016-10000-11465))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69849	13041-10000-28784	2123 S BEVERWIL DR	90064	5	126B165    35	4309003006	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	PIN	34.04535169	-118.39926568	PV1. PLAN CHECK FOR ROOF MOUNTED 9KW PHOTOVOLTAIC SYSTEM. TRANSFORMERLESS WITH (36) TRINA SOLAR # TSM-250 AND (1) POWERONE # AURORA PVI 3.6	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69850	18041-20000-31758	11415 N LEMONCREST AVE	91342	7	213B177   208	2529008028	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Issued	08/21/2018 12:00:00 AM	ADDRESS	34.27684	-118.35741	Plan check for a PV1 roof-mounted PV system. System size is 12.675 kWdc and consists of (2) inverter, (39) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69851	14041-20001-07212	15157 W GAULT ST	91405	6	183B145   804	2220001029	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.19949	-118.46381	Fee fore expedite only.****Roof mounted PV system with 4.25KWdc.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69852	14041-10000-17666	930 S MATEO ST	90021	14	123A217   176	5166012018	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.03159	-118.2321	T24 ONLY. RELACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES, TOTAL AREA 7155 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69853	17041-20000-33379	757 S ALAMEDA ST PHASE II	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.0318	-118.23916	CHANGE OF USE OF EXISTING TYPE IA COMMERCIAL BUILDING - CORE AND SHELL.  PHASE II OF CORE AND SHELL DISTRIBUTION BASIC POWER AND LIGHTING.BUILDING PERMIT UNDER 17016-10000-20345.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69854	17041-20003-32569	2408 E RIVERDALE AVE	90031	13	145-5A217 197	5445016015	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.09189	-118.23357	Changes to an approved set of plan. Changes include update main panel to 225A with 200A main disconnect.   Plan check only. $0 plan check fee per State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69855	11041-10000-09172	5072 S SLAUSON AVE	90230	11	108B161  1180	4217029903	OS-1XL, R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.00	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	01/11/2012 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	33.99368	-118.40672	New single story multipurpose Bldg. New 400 Amp service, board, and service. EPC is for power & Energy. (Full plan check per applicant request.)  Fire alarm pages are not in scope of the plan check, will if required be reviewed on a separate application.  No fees were charged for the fire alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69856	14041-20000-24807	7000 S HOOVER ST	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97589	-118.28691	New roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for House panel.  System size 2.08KW.zoning clearance under this application shall be applicable for all solar interconnections in this building	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69857	16041-10000-06629	3021 E ASBURY ST	90065	1	147A217    55	5454031024	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Expired	04/04/2018 12:00:00 AM	ADDRESS	34.09868	-118.22998	PV1, ROOF MOUNTED SOLAR SYSTEM USING A INVERTER. (12) MODULES AND (1) INVERTER 3.8KW  TOTAL SIZE IS 3.8 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69858	17041-20000-18651	11800 N SUSAN DR	91344	12	216B137   517	2609005003	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	PIN	34.28503706	-118.4982564	6.51$ permit fees due to senate bill 1222pv1install roof mounted pv system sized 13.2kw intercionnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69859	13041-20000-29819	3808 S CLOVERDALE AVE	90008	10	117B177    76	5029005002	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.01762	-118.35999	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING 18 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69860	10041-10000-14732	1355 W FLORENCE AVE	90044	8	102B197  1164	6014033030	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM			Corrections Issued	07/29/2010 12:00:00 AM	ADDRESS	33.97474	-118.2999	TENANT IN A JACK IN BOX RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69861	17041-20000-22095	2984 N ALLESANDRO ST	90039	13	150B213   669	5442024047	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.10578	-118.24435	Plan check for energy only. TI to office. New lighting (incl. emergency) - 3,932sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69862	19041-20000-06852	3777 N CAHUENGA BLVD	91604	4	162B177   445	2425002011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.13647	-118.36286	T24 PLAN CHECK ONLY, FOR FIRE DAMAGE REPAIRS TO EXISTING COMMERCIAL OFFICE BUILDING, LOW RISE. TOTAL SQUARE FOOTAGE = 6,453 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69863	15041-10000-02525	3828 N WINFORD DR	91356	3	162B121    71	2177041007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	34.1401	-118.55078	Plan check for a PV1 roof-mounted PV system. System size is 8.6 kWac and consists of (40) micro-inverters and (40) modules. Standard plan is being used. NOTE: Had building department issues that had to be cleared before pulling PV permit.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69864	19041-20000-12671	8535 W VENICE BLVD	90034	10	123B173   297	5065011036	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	12/19/2019 12:00:00 AM	ADDRESS	34.03514	-118.37862	ti to an existing commercial building.  new 400 amp service with 600 amp rated distribution board.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69865	18041-10000-33869	8900 W VENICE BLVD	90232	5	120B169    20	4312014093	(T)(Q)M1-2D	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM			Verifications in Progress	02/27/2019 12:00:00 AM	ADDRESS	34.02908	-118.38822	NEW FIRE ALARM SYSTEM.*****THIS IS PLAN CHECK ONLY. DESIGN CHANGE REQUIRED A SUPP. PERMIT TO BE  PULLED UNDER SUPP.  APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69866	11041-20000-11068	12025 E WATERFRONT DR 400	90094	11	105B165   915	4211011031	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM			PC Approved	01/11/2012 12:00:00 AM	PIN	33.98296022	-118.40473838	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR INTERIOR OFFICE  TI ON 4TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69867	17041-20001-43886	11740 W VANOWEN ST	91605	2	180B169    44	2322015010	R1-1, R3-1	South Valley	North Hollywood - Valley Village	NoHo		1232.03	Electrical	Electrical	Apartment			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.19379	-118.38943	07-17-2019 Changes to an approved set of plans, Changes include electrical service equipment reconfigured,  layout of service equipment in electrical room to remain, update drawing on single line diagram electrical distribution for common area. All changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69868	18041-20000-10474	8724 N OAK PARK AVE	91325	12	195B133   399	2690010010	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.22921	-118.50556	Plan check for the addition of a Tesla PowerWall to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69869	13041-10000-02476	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	04/25/2013 12:00:00 AM	ADDRESS	33.94248	-118.40461	This is atemp power  fed from an existing switch gear intented to use for construction in terminal 5 delta air line.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69870	10041-20000-24156	108 S CROFT AVE 1-6	90048	5	138B173   639	5511014004	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			12/03/2010 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.07419	-118.37407	New apartment building with 400 amp service.  Install general/emergency lighting in garage with more than 8 vehicles.  Low rise residential building. Plan check for energy only for indoor lighting .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69871	14041-20001-18176	14234 W MARGATE ST	91401	4	171B153   253	2248017015	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2014 12:00:00 AM			PC Approved	08/07/2014 12:00:00 AM	ADDRESS	34.16738	-118.4433	Modifications to approved set.  Change of array layout approved by fire department.  $0 submittal fee due to Senate Bill SB-1222. (((5.28KW PV1 roof-mounted system with (22) Enphase M250 microinverters and SolarWorld Plus SW280 Mono modules)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69872	18041-30000-33333	11911 W SAN VICENTE BLVD Suite 390	90049	11	129B145    78	4404025031	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Permit Finaled	10/22/2018 12:00:00 AM	ADDRESS	34.05295	-118.47002	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,508 sq. ft.Note: Building permit has been issued under 18016-10000-17741	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69873	17041-20000-34477	16415 W GLEDHILL ST	91343	12	198B137   140	2676010018	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.24214	-118.48984	pv1install roof mounted pv system sized 6.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69874	15041-10000-09953	7532 N CLYBOURN AVE	91352	2	186B177   225	2466029025	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/14/2015 12:00:00 AM	ADDRESS	34.2077	-118.36292	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69875	19041-10000-49767	3262 S BUTLER AVE	90066	11	117B157    30	4250020011	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	07/20/2020 12:00:00 AM	ADDRESS	34.02066	-118.43058	NEW ROOF MOUNTED PV SYSTEM WITH 128 PV TILES (TESLA SRV 3) AND 2 CENTRAL INVERTERS( DELTA SOLIVIA 5.2 & DELTA SOLIVIA 3.8  )  ON A SINGLE FAMILY HOME. SYSTEM SIZE IS 7.48 KWdc AND 9 KWac WITH 3 ENERGY STORAGE SYSTEMS (TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69876	10041-10000-11432	1200 N GETTY CENTER DR	90049	11	141B141     7	4429037022	A1-1-H, A2-1, PF-1XL, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2622.00, 2623.02	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	12/08/2010 12:00:00 AM	ADDRESS	34.08694	-118.47588	Ti in the library storage area of Getty Center. Plan check for Energy and T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69877	19041-10000-32194	416 N CITRUS AVE	90036	5	141B185  1154	5524031010	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM			Reviewed by Supervisor	08/27/2019 12:00:00 AM	ADDRESS	34.07882	-118.33956	INSTALLATION OF TESLA POWERWALL BATTERY TO AN EXISTING PV SYSTEM IN A SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69878	18041-20000-37578	5812 N COMANCHE AVE	91367	3	174B113    77	2151008052	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.17632	-118.57216	PV1.  Install 10.725 kW PV system.  (33) modules with 7.6 and 3.8 kW rated string inverters. 175A main breaker derate.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69879	14041-10001-08182	7007 W IMPERIAL HWY	90045	11	090B157    95	4129026903		West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	33.93185	-118.41447	CHANGES TO APPROVED: relocation of devices. no addition of devices. plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69880	18041-20002-38825	20105 W RINALDI ST #100-110	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.27543	-118.57209	Revisions to approved set.  Wiring detail change to include MC cable.  Minor panel schedule/circuit homerun and architectural revisions.  Changes on sheets E-1 and E-2 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69881	17041-10002-23609	20213 W BASSETT ST	91306	3	183B113   653	2135035023	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.19566	-118.57381	This is plan check only, changes to approved set with permit # 17041-10000-23609. Change inverter size from (1) SB5000TL + (1) SB6000TL under the original plan to be (2) SB5000TL under this scope. All others remain the same.Zero fee per senate bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69882	16041-10000-42916	10971 N JAMIE AVE	91331	7	210B161   697	2536019002	RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	02/08/2017 12:00:00 AM	ADDRESS	34.26934	-118.40617	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(20)MODULES-SPR-327-NE-WHT-D(1)INVERTER-SB6000TL-US-22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69883	18041-10000-23318	20364 W PLUMMER ST	91311	12	198B113    79	2748022075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.03	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.24253	-118.57759	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69884	18041-10000-24350	11428 W SHERMAN WAY	91605	2	183B169   683	2320001022	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM			Verifications in Progress	10/18/2018 12:00:00 AM	ADDRESS	34.20103	-118.37983	T.I. FOR (N) FULFILLMENT CENTER WITHIN (E) COSTCO.INSTALL NEW PANELS & LOAD. FULL PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT: 18016-10000-20836	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69885	15041-20000-35736	1622 N WILCOX AVE	90028	13	148-5A187 245	5546007006	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.10042	-118.33085	SYSTEM UPGRADE TO 800 AMPS.  EXISTING THREE STORY HOTEL BUILDING 52 ROOMS.  PLAN CHECK FOR POWER AND ENERGY. 9332 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69886	17041-10000-45609	700-800 WORLD WAY term 7-lev 2	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	Remodel existing men's locker rooms #6 and #9 at  United terminal 7Plan check is for title 24 and1 ea emergency circuit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69887	18041-20000-42659	3314 N LUGANO PL	90068	4	159B189   134	5581019018	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.1284	-118.32221	Plan check for PV roof mounted system, system size: 6.0kW DC, 7.6kW AC with 20 PV Modules and 1 inverter(7.6KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69888	17041-10000-01445	8500 W BEVERLY BLVD 618	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	02/27/2017 12:00:00 AM		Permit Finaled	04/13/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR POWER AND ENERGY. TI TO AN EXISTING GLASSES RETAIL STORE. SCOPE OF WORK INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1535 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69889	19041-10000-32541	10250 W SANTA MONICA BLVD 1370	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Issued	09/13/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check for First T.I. to existing retail store. Main panel for TI is 200A,480/277V, 3Ph,4W. Area of scope 2556SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69890	15041-20000-29646	1157 S BUNDY DR 1-33	90049	11	126B145   135	4264026030	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			09/09/2015 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.04464	-118.46824	Plan check for power and energy. Adding new service and new lighting. Total sqft. 28,694.New 33 unit 4 story type V-A apartment over one level of type I-A at ground floor and one level of type I-A subterenean garage. Fire alarm variance has been submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69891	12041-10000-13129	13603 W MARINA POINTE DR	90292	11	105B153    74	4229003066	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Apartment			06/06/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	33.98559	-118.44433	Plan check T24 outdoor lighting for perimeter area and open courtyard corridor. Site located in methane zone. No installation in hazardous area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69892	14041-10000-34196	1154 S ROBERTSON BLVD	90035	5	132B169   808	4332015040	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.05546	-118.38352	Energy plan check for office T.I (indoor and outdoor) Total area 4595 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69893	16041-10003-33650	3185 E WASHINGTON BLVD	90023	14	117A223    39	5169020003	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Approved	04/17/2017 12:00:00 AM	ADDRESS	34.01526	-118.21058	$0 PLAN CHECK FEE DUE TO SENATE BILL 1222 FROM 2012CHANGES TO APPROVED SET OF PLANS. CHANGE TO WIRE SIZE DUE TO TEMPERATURE CALCULATION. NOW USING #6 AWG. PC ONLY. NO OTHER CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69894	17041-10000-01977	2760 W PICO BLVD	90006	1	129B197  1142	5075009026	C2-1VL	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.04704	-118.29903	T24, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, TOTAL AREA 6810 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69895	19041-20000-19944	13900 W POLK ST	91342	7	228B153   466	2503007019	RA-1-K	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.31944	-118.43621	PV1.  Install 10.23 kW DC / 8.69 kW AC roof mounted grid tied PV system.  (31) modules with 3.8 and 7.6 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69896	15041-10000-28015	1450 S POINT VIEW ST	90035	10	129B173   604	5068012038	Currently Not Available	Central	Wilshire			2167.00	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Info Complete	10/06/2015 12:00:00 AM	ADDRESS	34.05053	-118.37019	Methane detecting system for a 4-story apartment; Scope includes ( 1) control panel, and (12) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69897	18041-10000-10693	647 S SAN PEDRO ST	90014	14	126A213    23	5148025009	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			03/23/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	03/07/2022 12:00:00 AM	ADDRESS	34.04132	-118.24643	Plan check per applicant request. Plan check for power and residentail lighting requirements. Addition of load to each unit and new lighting in each dwelling units.B#18016-10000-08890	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69898	17041-20000-35053	4101 S REDWOOD AVE	90066	11	108B153   929	4230006016	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM			PC Info Complete	10/18/2017 12:00:00 AM	ADDRESS	33.99086	-118.44043	Plan check for power and energy. Project site is an existing commercial building with a new 2nd story addition. Project scope is a core and shell. Total lighting area = 719 sq. ft.Note: Electrical service and distribution equipment has been plan-reviewed and permitted under 17041-20000-03306. Building permit has been issued under 16014-20000-04557	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69899	16041-10001-04766	727 E 33RD ST	90011	9	117A207    85	5120024017	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Expired	08/27/2018 12:00:00 AM	ADDRESS	34.0159	-118.26366	CHANGES TO APPROVED SET.  NEW MSP LAYOUT WITH EXISTING LOADS BEING TRANSFERED TO NEW SUBPANEL.PV1, INSTALL NEW 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(23) MODULES:SILEVO TRIEX U290 BALCK    (2) INVETER: ABB PVI-3.0-OUTD-S-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69900	14041-10000-01510	12701 W VAN NUYS BLVD STE. A	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.27621	-118.41056	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK DONE TO BE INDOORS. 4050 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69901	15041-20000-23700	15760 W STRATHERN ST BLDG. 2	91406	6	189B141    83	2206003007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.21559	-118.47701	Plan check for power and energy.  Total area = 1,576 sq. ft. (indoor) + 100 sq. ft. (outdoor)  T.I. to existing office and storage space.  Plan includes three buildings (three seperate permits)  15760 Strathern St. - Building 1 - 15041-20000-23696  15760 Strathern St. - Building 2 - 15041-20000-23700  15800 Strathern St. - Building 3 - 15041-20000-23703	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69902	15041-10000-36377	12250 W MONTAGUE ST	91331	7	204B165   169	2537018024	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.25595	-118.39963	Remove HID light fixtres and replace new LED fixtures. sq ft = 105232	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69903	17041-10000-09148	245 N SOTO ST	90033	14	129A223   353	5183004028	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.04632	-118.20835	Plan check for Title 24 only in existing space T.I. remodel. Total area: 2376 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69904	19041-10000-05335	989 S DEWEY AVE	90006	10	129B197   143	5078005025	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2133.10	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.05305	-118.29597	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69905	18041-10001-27019	600 S PIER A ST	90744	15	024B205   671	7440014904	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM			PC Approved	04/11/2019 12:00:00 AM	ADDRESS	33.7626	-118.26693	<<<EXPEDITE>>> NEW PV SYSTEM MOUNTED ON CARPORTS WITH 2080 PV MODULES AND 23 INVERTERS WITH 480 VOLT OUTPUT. SYSTEM SIZE  904.8 KWDC/690KWAC<<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03434	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69906	15041-10000-05568	7001 N SOPHIA AVE	91406	6	183B137    76	2224011905	[Q]M2-1VL, [T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.19773	-118.48731	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 23832 SQ FT. **THIS APPLICATION COVERES PLAN CHECK FEE FOR TWO BUILDINGS IN THIS PARCEL, AND ONE PERMIT FOR #1 BUILDING.**	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69907	14041-20000-26215	8734 N WHITE OAK AVE	91325	12	195B129   364	2768013013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.22967	-118.51986	(($0 permit fee due to senate bill 1222 from 2012))\PV1 SFD. TOTAL SYSTEM SIZE 17.2KW AC USING MIVROINVERTER. USING ENPHASE M250. TOTAL OF 70 MODULES. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69908	17041-10000-21953	10250 W SANTA MONICA BLVD #S1470	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	First tenant  Grom Gelateria's Remote Storage Ste. S1470 , 180 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69909	15041-10000-37920	12126 W WATERFRONT DR	90094	11	105B161  1218	6032035036	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	33.98076	-118.40716	new 6 story core and shell. this is new fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69910	19041-10000-14869	3400 S MAIN ST	90007	9	118-5A205 218	5120006016	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.01841	-118.27255	Remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69911	15041-10000-06130	606 N FIGUEROA ST	90012	1	135A213   324	5407004040	C2-2D	Central	Central City North	Historic Cultural	YES	2071.01	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.06276	-118.24601	PV2, 150KW roof-mounted system including (2) Solectria PVI 75KW inverters, (10) combiner box, and (660) INnotech Solar 260W modules interconnecting to a  pull section of the main service panel. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69912	15041-20000-03693	6925 W HOLLYWOOD BLVD	90028	13	147B181   112	5548004022	C4-2D-SN, R4-2D	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.10171	-118.34113	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SMALL STORE. 320 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69913	17041-20000-45510	11150 W GAULT ST	91605	2	183B173   146	2319022002	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Closed	01/23/2018 12:00:00 AM	ADDRESS	34.19927	-118.37408	Plan check for fire alarm system.New central station service monitoring system for commercial building. 1 FACP. 8 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69914	12041-20001-13115	8720 S WESTERN AVE	90047	8	096A193    12	6037014027	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM			PC Approved	07/11/2012 12:00:00 AM	ADDRESS	33.9585	-118.30883	Changes from previously approved plans.  Additional indoor light fixtures, combine suite 102 and 103 to one tenant type, and new outdoor lighting.  Plan check for energy only.Note:  Permit is under the original plan check number.*****T.I. to existing building in suite 101, 102, and 103.  Install general/emergency lighting.  Plan check for energy only.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69915	15041-10000-43830	24105 S FRAMPTON AVE	90710	15	039B197    42	7439011038	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	33.805	-118.29924	"TI IN AN EXISTING COMMERICIAL BLDG. Existing1000 A Service, New panels, 2 @ new 75KVA transformers. Total sq ft = 13180  -  ""COMPLY WITH DEPARTMENT ORDER effective date05/14/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69916	18041-20000-08181	11350 W PALMS BLVD	90066	11	117B157   350	4249026028	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/23/2021 12:00:00 AM	ADDRESS	34.01769	-118.42601	PV2.  Install 78.5 kW roof mounted grid tied PV system.  (297) modules with (3) 20kW rated string inverters.Fees $0.00 Due to California Senate Bill 1222 and Assembly Bill 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69917	13041-10000-28435	6160 N BELLAIRE AVE	91606	2	177B161   444	2332024009	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	12/14/2013 12:00:00 AM	ADDRESS	34.18284	-118.40929	PV1, INSTALLING ROOFMOUNTED SOLAR PANEL INTERCONNET WITH NEW MAIN SERVICE PANEL. MICRO INVERTER STANDARD PLAN. MICROINVERTER: ENPHASE M215-60-2LL-S22.  34 MODULES; SOLAR WORLD SUN  MODULE 250 POLY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69918	14041-10000-10955	6641 E CHURCH ST	90042	14	157-5A235  52	5716017008	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.04	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2014 12:00:00 AM	04/25/2014 12:00:00 AM		Permit Expired	05/19/2016 12:00:00 AM	ADDRESS	34.12598	-118.16897	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69919	11041-10000-18473	1417 N NORTH MAIN ST	90012	1	135A217    58	5409005016	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			PC Approved	08/30/2011 12:00:00 AM	ADDRESS	34.0652	-118.23093	ENERGY ONLY PLAN CHECK FOR ADDITION TO AN EXISTING WAREHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69920	17041-20001-19012	817 N VINE ST Bldg A	90038	13	141B185   173	5533030026	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.0858	-118.32679	4/3/2018changes to an approved set of plans.  changes noted delta A.  changes include new inverter and associated circuits for EM lighitng and revisions to the energy calculations.  (((Plan check for power and energy. Renovation of existing office building (Bldg A) and addition of 1,500sqft mezzanine. Core and shell. Fed from new 3000A 480V 3ph-4W service. Methane zone.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69921	16041-20000-29184	14418 W BERG ST	91342	7	222B149   958	2508021004	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Expired	09/28/2018 12:00:00 AM	ADDRESS	34.30221	-118.44718	install a roof-mounted solar array on a SFD.  Interconnect a 200A MSP. 3kW ungrounded system. (13) 255W PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69922	17041-20001-31694	2967 N HOLLYRIDGE DR	90068	4	156A191    37	5583017001	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.12259	-118.3199	Expedited plan check fee. PV1.  Install 8.45 kW roof mounted grid tied PV system.  (26) modules with 7.6kW rated string inverter.  13.5 kWh backup energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69923	10041-20000-17037	3223 W 6TH ST	90020	4	135B197  1267	5502024***	C2-1, PB-1	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.06375	-118.29255	PLAN CHECK POWER AND ENERGY TI IN RETAIL STORE. FIRST TIME TENANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69924	16041-10006-10543	4865 N LOUISE AVE	91316	5	168B133   205	2290002003	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.15843	-118.50997	CHANGES TO APPROVED SET OF PLAN. DOWN SIZE OF CONDUCTORS FROM LOAD CENTER TO MSP AND SMP,AND CHANGING SMP AND LOAD CENTER AIC RATING.ORIGINAL PERMIT DESCRIPTIONPV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 29.430KWdc / 25.4KWac.(90)MODULES-SPR-327NE-WHT-D(4)INVERTERS-2 SMA SB7700TL-US-22 AND 2 SMA SB5000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69925	12041-10000-06648	22509 W HARTLAND ST	91307	3	183B101   699	2024029006	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	08/22/2012 12:00:00 AM	ADDRESS	34.19473	-118.61706	New rooftop,  photovoltaic system for an existing single family residence.   5.16kw system using Enphase M215 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69926	19041-10000-38969	4672 E YORK BLVD	90041	1	156A223   136	5474018005	RD3-1, [Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.02	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	07/16/2020 12:00:00 AM		Issued	07/16/2020 12:00:00 AM	ADDRESS	34.12269	-118.21421	FIRST TIME TENANT ON THE FIRST FLOOR - NEW RESTAURANT. INSTALLING NEW PANELS, CIRCUITS & LIGHTS. BULDING PERMIT: 18016-10000-17467	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69927	13041-10000-15269	9410 N TOPANGA CANYON BLVD	91311	12	198B101   334	2746013038	[Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Issued	06/11/2013 12:00:00 AM	ADDRESS	34.2412	-118.60593	FA FOR OCCIDENTAL BUSINESS CENTER. 180 DEVICES AND 1 PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69928	12041-10000-22798	2920 S SEPULVEDA BLVD	90064	5	120B157   121	4251003035	C2-1VL, R4P-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	12/28/2012 12:00:00 AM	ADDRESS	34.02823	-118.42906	Change to lighting and receptacles for an existing low-rise office building on all three floors.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy.  NO change to existing emergency lighting, emergency lighting is Not a part of this plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69929	15041-10000-14822	8468 W MELROSE PL	90069	5	141B173   514	5528017026	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	05/19/2015 12:00:00 AM		Permit Finaled	07/09/2015 12:00:00 AM	ADDRESS	34.0834	-118.37563	TI-24 TO AN (E) COMMERCIAL BUILDING. NEW LIGHTING AND NEW RECEPTACLES.  PC FOR ENERGY TOTAL SQ FT. 2752	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69930	19041-10000-11595	1019 E 4TH PL FLOOR 3	90013	14	127-5A217  60	5163018006	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.04195	-118.23327	FULL PLAN CHECK FOR FIRST TIME TENANT FOR - FULL FLOOR 7,773 SQFT. (LEVEL 3)OFFICE USE. THE SCOPE OF WORK INCLUDES INTERIOR NON-LOAD BEARING PARITTIONS, AND FINISHES - CONNECTED TO EXISTING SERVICE - NEW COONECTED LOAD IS APPROX. 200A OF CONNECTED LOAD USING TRANSFORMER(75KVA), TOTAL AFFECTED AREA = 10600 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69931	15041-20000-05247	6826 N YARMOUTH AVE	91335	3	183B129   979	2122002013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2015 12:00:00 AM	02/23/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.19482	-118.51956	PV1. Install roof mounted PV system interconnected with main service panel. System size 3.6 kW.16 Enphase M215 Microinverters16 Sunmodule SW-250 Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69932	11041-10000-06656	4020 S MARLTON AVE	90008	8	114B185    92	5032002065	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	34.01159	-118.33819	New fire alarm for a theater. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69933	17041-20001-29728	11765 W LAURELCREST DR	91604	2	162B169  1055	2377003021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.13684	-118.38909	9.22.2017 - Plan check for changes to approved set. Add disconnect ahead of battery backup load center in garage. Only change - clouded.======Install 13.5 kWh battery backup system for SFD.  (E) PV system on site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69934	19041-20000-49123	245 N VERMONT AVE	90004	13	138B197   409	5518033001	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2112.02	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	06/12/2020 12:00:00 AM		Issued	06/12/2020 12:00:00 AM	ADDRESS	34.07588	-118.29188	Service upgrade to 120/240V, 3Ph, 800Amp with 4 @ 200Amp Sub Panels. Core & Shell Only.There are NO connected loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69935	18041-10004-07688	7540 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			11/22/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.94052	-118.42863	CHANGES TO APPROVED SET. ADDITION OF 2 CIRCUITS FOR EF AND SMOKE DAMPED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69936	18041-20002-44304	8526 N VAN NUYS BLVD	91402	6	192B149   118	2638001044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.22557	-118.44877	04-22-2019 Changes to an approved set of plans, changes include remove note number 4(not applicable). Changes has been clouded as delta 5. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69937	18041-20000-07503	16632 W ARMSTEAD ST	91344	12	213B137   326	2610025014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.28171	-118.494	pv1install roof mounted  pv system sized 7.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69938	18041-20000-18979	9200 N OAKDALE AVE 3rd Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is the 3rd floor of an existing high-rise building. Project scope is a tenant improvement. Total lighting area = 2,000 sq. ft.Note: Building application has been generated under 18016-20000-06515	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69939	13041-20000-17367	18118 W LASSEN ST PV-1	91325	12	201B125   108	2764021003	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2013 12:00:00 AM	09/11/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.24985	-118.52842	PV-1. More than two strings per inverter. One 2kW inverter and one 7.5kW inverter.  Plan Check/Permit is for PV system only, NOT for Upgrade to main service or derating of main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69940	14041-10000-31717	10931 W PICO BLVD	90064	5	126B157  1043	4322009020	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.03923	-118.43075	Energy plan check for office T.I	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69941	19041-10001-53600	444 S FLOWER ST STE 500	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			PC Approved	12/27/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	VOIDCHANGE OF ADDRESS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69942	15041-10000-06152	7327 N LOMA VERDE AVE	91303	3	186B109   856	2112016019	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.20374	-118.58977	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 4.0KW INTERCONNECTED WITH MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69943	16041-20000-01485	8012 S READING AVE	90045	11	099B169   962	4105025022	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	33.96559	-118.38158	Plan check for PV roof mounted system. System size: 3.8kW with 13 modules and 1 inverter. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69944	16041-20001-37465	7855 N LINDLEY AVE	91335	12	189B125   558	2102017058	(T)R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	01/25/2017 12:00:00 AM	ADDRESS	34.2134	-118.52751	Expedited per applicant request.Plan check for a PV2 roof mounted PV system. System size is 7.6kW AC and consist of 1 inverter and 27 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69945	14041-10000-02377	3564 N MANDEVILLE CANYON ROAD	90049	11	153B133    47	4490021011	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	02/28/2014 12:00:00 AM		Permit Finaled	04/07/2014 12:00:00 AM	ADDRESS	34.11342	-118.50034	PV1, Install 8 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel. (1)Transformerless inverter: SOLAREDGE SE6000A-US-ZB-U(32) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69946	17041-20000-19356	1500 S ESPERANZA ST	90023	14	117A227    43	5192005010	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			Reviewed by Supervisor	06/22/2017 12:00:00 AM	ADDRESS	34.01563	-118.20086	Electrical distribution improvements for an (E) commercial facility.  Plan check for power.  New 2000A 480Y/277V 3-phase service.  No associated building permit - electrical improvements only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69947	18041-20000-15729	12991 W BLAIRWOOD DR	91604	2	162B161   344	2385017004	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Issued	07/05/2018 12:00:00 AM	ADDRESS	34.14182	-118.41689	NOTE: Permit Fees are reduced per Senate Bill 1222.Plan check for PV roof mounted system. System size: 22.1kW with 75 modules and 75 microinverters 6 source circuits combined at load center and connected to existing 400A panel in Single Family Dwelling.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69948	18041-10000-20854	11150 W OLYMPIC BLVD 6TH FL-STE 610	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	07/24/2018 12:00:00 AM	ADDRESS	34.03956	-118.43857	PLAN CHECK FOR TITLE 24 ONLY FOR OFFICE TI - TOTAL AFFECTED AREA = 3523 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69949	17041-20000-39454	11600 W SHERMAN WAY	91605	2	183B169   692	2320001042	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	03/01/2018 12:00:00 AM		Issued	03/01/2018 12:00:00 AM	ADDRESS	34.20097	-118.38442	Plan check for a PV2 roof-mounted PV system. System size is 192 kWac and consists of (8) inverters, (864) modules, and (5) distribution boards.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69950	15041-20000-36645	12746 W JEFFERSON BLVD # 1140	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	33.97756	-118.41709	"Change of Use from retail to restaurant. ""da Poke Spot."". PC for Power & Energy. Total area: 890 sq. ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69951	17041-10000-32699	12246 W VENTURA BLVD	91604	2	162B165   239	2369004026	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.1429	-118.40014	FIRE DAMAGE REPAIR. PC FOR T24 ENERGY ONLY. REPLACING LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69952	16041-20000-26885	15301 W VENTURA BLVD	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/29/2016 12:00:00 AM			PC Approved	07/29/2016 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for Title 24 only in existing space. Total area: 1,225 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69953	13041-10000-33872	216 S ALAMEDA ST	90012	14	129A215   239	5163009005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/05/2013 12:00:00 AM			PC Approved	12/05/2013 12:00:00 AM	ADDRESS	34.04645	-118.23792	Plan check for existing general/emergency indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69954	17041-10001-12442	1726 W PICO BLVD	90015	1	127-5A203  49	5135020022	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM			PC Approved	07/05/2017 12:00:00 AM	ADDRESS	34.04527	-118.27865	Changes to approved set. Changes marked under delta 1.  Scope includes removing of day light controls and update to luminaire schedule addition of area controls to floor plan.  Plan check only! permit pulled under master PC FOR ENERGY. INTERIOR T.I. TO EXISTING RETAIL. NO CHANGE OF USE. TOTAL AREA 15785 SQ FT.B # 17016-10000-06865	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69955	18041-10000-10568	700 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Info Complete	03/22/2018 12:00:00 AM	PIN	33.94153561	-118.3984113	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES INSTALLING NEW LIGHTS FOR OFFICE SPACE OFFICE SPACE IN EXISTING AIRPORT BUILDING. TOTAL AFFECTED AREA IS 405 SQ. FT. B#18016-10000-03226	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69956	16041-10000-44822	1680 N VINE ST UNIT 4	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	04/26/2018 12:00:00 AM	ADDRESS	34.10133	-118.32648	CHANGE OF USE TO RESTAURANT. PC FOR POWER AND ENERGY. NEW LIGHTING AND KITCHEN EQUIPMENT. NEW PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69957	15041-10001-21832	437 S HILL ST	90013	14	129A211    13	5149028004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM			PC Approved	02/04/2019 12:00:00 AM	ADDRESS	34.0495	-118.2514	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 49 ONLY CHANGES ON FIRE PUMP WIRING AND CHANGING FROM FULLY RATED TO SERIES RATED. RELOCATING JOCKEY PUMP, AND REVISING PANEL SCHEDULES, AND LOAD CALCULATIONS.NOTE:PERMIT IS PAID UNDER MASTER APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69958	18041-20000-41513	22908 W GAULT ST	91307	12	183B097   327	2026005019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.19854	-118.62587	pv1install roof mounted pv system sized 3.8KW interconnected with msp.(1) tesla powerwall 5Kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69959	18041-20001-19178	4108 N KRAFT AVE	91604	2	162B169   204	2368020023	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	06/07/2018 12:00:00 AM	ADDRESS	34.14276	-118.37992	Expedited plan check fee. PV1.  Install 17.55 kW roof mounted grid tied PV system.  (54) modules with 7.6 and 6.0 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69960	19041-20001-12359	9930 N OWENSMOUTH AVE NO 2	91311	12	201B105    38	2747014***	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.25082	-118.60153	PV1. INSTALL 4.65 KW DC PV SYSTEM WITH (15) MODULES/OPTIMIZERS AND (1) INVERTER(SE3800).NOTE: INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-12359	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69961	19041-20000-34467	10993 W BLUFFSIDE DR	91604	2	162B173   276	2366021042	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	09/02/2022 12:00:00 AM	ADDRESS	34.14191	-118.36968	PV2 BUILDING #2 (N) 18.4 KW AC/20.52 KW DC ROOFTOP PV SYSTEM ON EXISTING APT BUILDING. SCOPE OF WORK CONSISTS OF (57) PV MODULES WITH (3) 6 KW INVERTER, AND A 200A PANEL BOARD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69962	16041-10000-45583	8700 W BEVERLY BLVD STE2097-8	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	34.07666	-118.3805	PC FOR ENERGY. TENANT IMPROVEMENT TO (E) OFFICE, (E) SINGLE SRVICE AND SWITCHGEAR. TOTAL AREA 430 SQ FT.B#16016-100000-31044	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69963	17041-30000-19870	12027 W VENICE BLVD	90066	11	114B157  1257	4248029037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.00603	-118.42987	Plan check for power and energy. Project site is a new 3-story mixed use building: (1) level of office/garage and (2) levels of residential units. Work includes a 600-amp service and 4,760 sq. ft. of lighting area.Note: Building permit has been issued under 16010-30000-01809	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69964	13041-10000-27086	4717 N SANTA LUCIA DR	91364	3	168B101   974	2171022053	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1380.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.15309	-118.60459	PV1. ROOF MOUNTED 2.75KW PHOTOVOLTAIC SYSTEM. TRANSFORMERLESS INVERTER USING(11) TRINA SOLAR # TSM-250PA05.18(1) SOLAREDGE #SE3000A-US WITH POWER OPTIMIZER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69965	10041-10000-13236	715 W 3RD ST	90012	9	132A211    47	5151014033	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	12/20/2010 12:00:00 AM	PIN	34.0545108	-118.25249769	Repacing 5000 ton with a 2500 ton chiller.  Installing new MCC with VFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69966	13041-20000-23729	7502 N JOLENE CT	91605	2	186B165   306	2307023***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			Reviewed by Supervisor	09/17/2013 12:00:00 AM	ADDRESS	34.20695	-118.40101	PV1 TRANSFOMERLESS SYSTEM. 25 MODULES AND 1 INVERTER. ((((new system was specified, new submittal required. this application may be discarded.))))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69967	17041-10000-05971	19641 S HARBORGATE WAY	90501	15	057B193    23	7351021042	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	04/26/2017 12:00:00 AM	ADDRESS	33.85169	-118.30372	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 217150 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
69968	15041-20000-16336	10530 W VICTORY BLVD	91606	2	177B177    90	2414019012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.18498	-118.36061	Plan check for a PV2 roof-mounted PV system. System size is 30 kWac and consists of (3) inverters, (120) modules, and (1) load center.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69969	17041-30000-44011	3945 W INGRAHAM ST	90005	10	132B193   121	5092030022	R4P-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Apartment			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.06079	-118.31283	Plan check for a fire alarm system for an apartment building. Fire alarm consists of (1) FACP and (61) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69970	10041-10000-01849	10497 W WILSHIRE BLVD	90024	5	135B153   380	4360029015	[Q]R5-3	West Los Angeles	Westwood			2651.00	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM	02/03/2010 12:00:00 AM		Permit Finaled	04/06/2010 12:00:00 AM	ADDRESS	34.06468	-118.4322	TI IN AN EXISTING CHURCH.  PLAN CHECK IS FOR TITLE 24 - ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69971	12041-20000-16124	11348 W BURBANK BLVD	91601	4	174B173   950	2350008055	C2-2D	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.17194	-118.37797	New fire alarm system for a high rise hotel building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69972	14041-20000-15353	17054 W CANTARA ST	91406	6	192B133   428	2204028022	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.21931	-118.50441	PV1.  Install 6.88 kW roof-mounted, utility-interactive PV system.  Transformerless inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69973	16041-20001-23916	715 S KINGSLEY DR	90005	10	132B193   367	5093021024	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.05927	-118.30321	PV2.  Install 59.8 kW DC roof-mounted PV system.  (176) modules with (4) 10kW transformerless central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69974	10041-10000-10555	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Public Safety Only			06/03/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	ADDRESS	34.07417	-118.26931	TENANT IMPROVEMENT ON THE 6TH, 7TH AND 11TH FLOORS OF AN EXISTING BUILDING- NEW FA DEVICES , VOICE EVAC PANEL AND 3 EA REMOTE POWER SUPLLIES.PLAN CHK WAS REQUESTED BY THE CONTRACTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69975	12041-10000-12966	1131 S WESTWOOD BLVD	90024	5	132B149   100	4363023029	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM	09/05/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.0601	-118.44538	TENANT IN  KITCHEN AREA OF AN EXISTING RESTAURANTPLAN CHKIS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69976	16041-10001-45002	10250 W SANTA MONICA BLVD UNIT 1820	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Changes to approved set under Delta-5 only . Permit shall be issued under master #16041-10000-45002	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69977	14041-20000-30570	12101 W VAN NUYS BLVD	91342	7	216B165   292	2531001***	(T)(Q)RD6-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	12/08/2014 12:00:00 AM	ADDRESS	34.28562	-118.39579	PV1 CENTRAL/STRING INVERTER STANDARD PLAN. SIZED 6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69978	15041-20000-03739	1243 S OLIVE ST	90015	14	126A207   200	5139023038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.03859	-118.26331	800 AMP TEMP POWER FOR CONSTRUCTION SITE. PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69979	14041-10000-00381	511 E PICO BLVD	90015	14	124-5A209 272	5145026037	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.0339	-118.25568	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 336 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69980	13041-20000-33520	1510 S LA BREA AVE	90019	10	129B181  1180	5070019037	C2-1-O	Central	Wilshire			2172.00	Electrical	Electrical	Commercial			12/03/2013 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.04643	-118.34501	NEW ADDITION TO & CHANGE OF USE &  FROM AUTO REPAIR SHOP TO DRIVE THRU SELF SERVICE CARWASH.  Full Plan Check requested by applicant.  METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69981	19041-20000-02223	8738 S FIGUEROA ST	90003	8	096A201   130	6038002044	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	33.95761	-118.2825	Plan check for new fire alarm system, for 3 story building 5 units apartment. Total Fire alarm devices: 26  and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69982	13041-20000-04680	970 N MONUMENT ST #103	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM			PC Approved	02/22/2013 12:00:00 AM	ADDRESS	34.04646	-118.52393	Plan Check only for Energy to an existing retail space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69983	16041-10000-37011	308 W 14TH ST	90015	14	124-5A207  87	5134020004	C2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.03661	-118.26463	PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 6000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69984	19041-20000-02748	3827 S MUIRFIELD ROAD	90008	10	117B181   405	5045002011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.0166	-118.34278	Plan check for PV roof mounted system with Energy Storage System, system size: 4.8KW with 15 PV Modules and 1 inverter(7.6KW), LG Chem 9.8kWh.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69985	17041-20001-11818	4300 S LINCOLN BLVD	90292	11	105B153    81	4212004011	[Q]M1-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM			PC Approved	05/11/2017 12:00:00 AM	ADDRESS	33.98556	-118.443	"PLANCHECK ONLY FOR POWER ONLY. SERVICE UPGRADE ON A METHANE ZONE PERMIT UNDER: 17041-10000-11818UPGRADE PANEL FROM 200A TO 400A AND (1) NEW SUBPANEL  ""COMPLY WITH DEPARTMENT ORDER effective date12/03/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69986	11041-10000-07119	165 S MUIRFIELD ROAD	90004	4	138B185   345	5515010016	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2011 12:00:00 AM	05/02/2011 12:00:00 AM		Permit Finaled	07/13/2011 12:00:00 AM	ADDRESS	34.07172	-118.32861	INSTALLATION OF A NON-REQUIRED STANDBY GENERATOR AND ATS AND DISTRIBUTION BOARD; THE EXISTING SWBD SECTIONS WILL BE  ABANDON AND THE SWBD WILL BE USED AS  TO CONNECT THE EXISTING SERVICE CONDUCTORS TO THE NEW DISTBD TO WHICH THE EXISTING LOADS WILL BE RECONNECTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69987	18041-10000-40813	3743 E WHITTIER BLVD	90023	14	120A229    17	5188008021	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Issued	10/25/2018 12:00:00 AM	ADDRESS	34.02426	-118.19256	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69988	19041-10000-43384	10420 N DE SOTO AVE	91311	12	204B109    15	2706015017	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.25957	-118.58833	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 16.69KWac USING 53 SUNPOWER SPR-320E-WHT-D MODULES & 53 Enphase IQ7X 96-2-US MICROINVERTERS . CONNECTED TO NEW 200Amp SERVICE.Fees $24.39 Due to California Senate Bill 1222 and AB 1414NEW SERVICE PANEL UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
69989	16041-10000-24831	9350 N CRYSTAL VIEW DR	91042	7	198B201   372	2572045004	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	08/12/2016 12:00:00 AM	ADDRESS	34.23832	-118.28242	PV1 roof mounted solar system installtion to a single family home. Installing 27 microinverters rated at 320 watts each for a total system size of 8.64Kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
69990	16041-10000-01933	5020 W MELROSE AVE	90004	4	141B193   607	5522010001	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM			PC Approved	01/19/2016 12:00:00 AM	PIN	34.08332529	-118.30991285	PC for energy only to  a retail space. Adding new lighting and power. Total sq ft = 614. *** PC ONLY NO PERMIT TO BE PULLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69991	16041-30000-22705	4227 S MCLAUGHLIN AVE 1-14	90066	11	111B161   369	4233007007	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.00093	-118.41878	NEW FIRE ALARM SYSTEM 73 DEVICES WITH 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69992	18041-20000-02218	14540 W ERWIN ST	91411	6	178-5A151 276	2241013029	[Q]C2-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			01/19/2018 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	07/20/2021 12:00:00 AM	ADDRESS	34.18343	-118.45017	1200A 208Y/120V service, distribution, power, and lighting for new building.  Plan check for power and energy.Building permit issued under 17010-20000-00056.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69993	13041-20001-13226	7600 S SEPULVEDA BLVD	90045	11	102B165   948	4106018001	[Q]C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			10/11/2013 12:00:00 AM			PC Approved	10/11/2013 12:00:00 AM	ADDRESS	33.97143	-118.39468	(((CHANGES MADE TO APPROVED SET OF PLANS. REMOVED BLUE BOX BECAUSE THERE IS AN EXISTING TIME CLOCK AT THE PROJECT SITE)))pc for energy only. less than 400A connected load. INTERIOR TENANT IMPROVEMENT FOR existing RETAIL STORE.  goodwill industries	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69994	11041-10000-14152	515 S FLOWER ST 32nd Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	07/08/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	T.I.  Replacing light fixtures in the lobby of the 32nd floor office.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69995	17041-10000-30232	927 N ORANGE DR	90038	4	144B181   716	5532010051	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.08796	-118.34173	MULTIMEDIA PRODUCTION TENANT. PLAN CHECK FOR POWER AND ENERGY. NEW 1200A SERVICE UPGRADE. B#17016-10000-24252	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
69996	16041-30000-19403	11611 W SAN VICENTE BLVD Suite 515	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM			PC Approved	06/02/2016 12:00:00 AM	ADDRESS	34.0541	-118.46261	Plan check for Title 24 only. Project site is a portion of the 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,501 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69997	17041-10000-11584	2478 N FLETCHER DR	90039	13	150A209    31	5437033011	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/10/2017 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.10724	-118.25482	PC FRO FA SYSTEM. NEW PANEL AND 25 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69998	10041-10000-14966	770 W WILSHIRE BLVD	90017	9	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/02/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	10/25/2010 12:00:00 AM	ADDRESS	34.04914	-118.25811	TENANT IMPROVEMENT ON THE FIRST FLOOR OF THE LACCD HEADQUARTERSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
69999	11041-10000-03866	6303 N OWENSMOUTH AVE 4TH-floors	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.18474	-118.60182	TI IN AN EXISTING OFFICE. EPC IS FOR T24 & LIGHTING. (complete plan check may required by field inspector)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70000	11041-10000-16763	1456 S CLUB VIEW DR	90024	5	135B157   396	4327026008	R1-1	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.06405	-118.42193	NEW 13.16 KW PV SYSTEM USING ENPHASE M215 MICRO-INVERTERS.  Variance is paid for.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70001	14041-10000-03745	457 N FAIRFAX AVE	90048	5	141B177  1210	5527031015	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	PIN	34.07986856	-118.361786	plan check for t24 enrgy. remodel lighting system in existing coffee shop	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70002	16041-10000-44568	2530 W FLORENCE AVE	90043	8	102B189  1405	4009002035	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	33.9744	-118.32179	PC FOR ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 11575 SQ FT. (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70003	16041-20003-44549	1060 S BROADWAY	90015	14	126A209   131	5139014011	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM			PC Approved	04/16/2019 12:00:00 AM	ADDRESS	34.0397	-118.25861	4/16/2019changes to an approved set of plans.  changes to equipment AIC ratings to reflect utility fault current value, fully rated system.  this is plan check only.  ((((Plan check for power and energy. Remodel (E) 10-story high rise building, convert from office to hotel. (2) New 1000A services. ~174 hotel units. T24: indoor area- 188,264sqft.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70004	19041-10000-17584	3540 W MARTIN LUTHER KING, JR BLVD	90008	10	114B185   221	5024009015	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Issued	05/10/2019 12:00:00 AM	ADDRESS	34.01076	-118.33426	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70005	19041-10000-28674	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Issued	07/25/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	PC for T24 only per inspectors request, scope of work includes new lighting and controls and equipment in a conscession stand #23. Total affected area is 1007 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70006	15041-10000-14660	1002 W CHILDS WAY	90089	9	120B197  1043	5039002029	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	34.02201	-118.28947	Full plan check for a 4-story with basement commercial building.  Scope mainly include  2-service  medium voltage (5kv/12.47kv) with 4000-Amp panel. Note. plan checker need to verify for additional fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70007	16041-20000-21032	6517 N VARNA AVE	91401	2	180B157   654	2329017012	RS-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.18892	-118.42483	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.07KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70008	19041-20000-14363	3632 S KEYSTONE AVE	90034	5	120B161   999	4314009030	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	12/31/2020 12:00:00 AM	ADDRESS	34.02304	-118.40879	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR NEW 10 UNIT 4-STORY APARTMENT BUILDING WITH A BASEMENT. SCOPE OF WORK INCLUDES 1 FACP AND 75 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70009	17041-10000-14422	917 W 71ST ST	90044	8	102B197   972	6013003019	[Q]R4-1	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	33.97561	-118.28981	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new LED ones.Area: 9055 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70010	19041-10000-08169	20911 S NORMANDIE AVE	90501	15	054B197   168	7349034031	R2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	33.83966	-118.2994	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 16 MODULES (LG330N), 16 OPTIMIZERS (SE P370) AND A CENTRAL INVERTER (SE6000H-US). SYSTEM SIZE IS 5.28 KWdc AND 6KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70011	11041-10000-20344	19481 S HARBORGATE WAY	90501	15	057B193    21	7351021016	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/23/2011 12:00:00 AM			PC Approved	11/02/2011 12:00:00 AM	ADDRESS	33.85326	-118.30372	T.I. to an office space in and existing warehouse.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70012	17041-20000-34454	14321 W JOY DR	91331	6	198B153  1030	2644027242	(T)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.42	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	09/22/2018 12:00:00 AM	ADDRESS	34.24164	-118.44527	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.66 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70013	13041-20000-22377	1000 S HOPE ST	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	12/13/2013 12:00:00 AM	ADDRESS	34.04346	-118.2617	PC FOR T24 ENERGY ONLY. NEW SUBWAY. LOW CONNECTED LOAD. TOTAL AREA 1925 SQ FT((CHANGE OF ADDRESS, NO FEE DEPARTMENTAL ERROR. ORIGINAL FEES COLLECTED UNDER APPLICATION# 13041-20000-22372)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70014	18041-20006-48715	8600 W LA TUNA CANYON ROAD	91352	7	198B189   116	2401028***	A1-1XL-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	ADDRESS	34.23699	-118.3204	7/24/19chages to an approved set of plans.  changes to EV subpanel feeder and OCPD at service panel.this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70015	17041-10000-41834	928 S BROADWAY Suite A	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.04154	-118.25658	Plan check for first time tanent in mix use building West Elm. Total area: 10,930 sq ftB#13010-10000-02211	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70016	17041-10001-19897	9006 N MERCEDES AVE	91331	6	195B157   286	2627013017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.23324	-118.42138	SUPPLEMENTAL TO PERMIT#: 17041-10000-19897 TO DERATE 175 AMP FOR SOLAR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70017	14041-10000-33811	912 N KENTER AVE	90049	11	138B137   219	4494023004	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.07518	-118.49214	INSTALL 7.395 KW DC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(29) MODULES: YINGLY YL255P-29B(1) INVERTER: ABB PVI-6000-OUTD-S-US-ZA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70018	18041-10000-23846	4238 S 7TH AVE	90008	10	114B189  1370	5023017038	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Expired	10/18/2023 12:00:00 AM	ADDRESS	34.00602	-118.32467	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(11)MODULES-LG330N1(11)OPTIMIZERS- SOLAREDGE OPTIMIZERS(1)INVERTER-SOLAREDGE SE7600A-USS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70019	14041-10002-17121	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/20/2018 12:00:00 AM			PC Approved	06/21/2018 12:00:00 AM	ADDRESS	34.03941	-118.25893	PC FOR CHANGES UNDER DELTA 24 ONLY. SCOPE INCLUDES REVISION TO NOTES FOR FIRE PUMP CONTROLLER CONDUITS. THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70020	17041-20000-08183	11655 N HUNNEWELL AVE	91342	7	213B165   306	2531021017	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.2816	-118.39872	Plan check for installation of solar pv array, roof-mounted on SFD. Interconnect with a 200A MSP.6.08kW ungrounded system. (19) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70021	18041-10001-32009	7317 N HASKELL AVE	91406	6	186B141   858	2206037111	R3-1, [Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.2033	-118.47511	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70022	19041-10000-35114	15635 W LEADWELL ST	91406	6	186B141   641	2206029023	(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.20404	-118.47393	Replacing Existing HID Fixtures with new LED Fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70023	17041-10002-17169	3763 S WALL ST	90011	9	117A205   431	5121023003	RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	Apartment			08/02/2017 12:00:00 AM			PC Approved	08/02/2017 12:00:00 AM	ADDRESS	34.01319	-118.27108	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES MADE TO NOTE 3 UNIT APARTMENT. REVISED ROOF LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70024	11041-10000-08441	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/27/2011 12:00:00 AM	05/12/2011 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	TEMPORARY POWER FOR CONSTRUCTION AT BRADLEY TERMINAL WEST CONCOURSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70025	12041-10000-18998	1318 N NORTH SPRING ST	90012	1	136-5A217  91	5409006051	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/13/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.06632	-118.23289	New rooftop 28kw photovoltaic system for an existing low-rise commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70026	14041-20000-17335	401 N LA CIENEGA BLVD	90048	5	141B173  1372	4337009001	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.07877	-118.37677	plan check Tittle 24 only on existing restaurant with 3041 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70027	19041-20000-13433	9021 W EXPOSITION BLVD	90034	5	120B165    53	4312013033	M1-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2701.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.02869	-118.39269	TI and change of use to retail/nursery.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70028	13041-10000-12959	19313 W VICTORY BLVD	91335	3	180B117   654	2131010026	C2-1VL	South Valley	Reseda - West Van Nuys	Reseda		1349.01	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.18679	-118.5543	13041-10000-12959in an existing Starbucks STORE, TENANT IMPROVEMENT.eMERGENCY LIGHTING FIXTURES TO REMAIN THE SAMEPLAN CHK S FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70029	13041-10001-34394	536 N GRAMERCY PL	90004	4	141B193   961	5522013019	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.08141	-118.3124	Expedited RSES plan check per applicant request.{{{PV1, install 4 kw DC roof-mounted solar array for a 1-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3800A-US. (16) modules: Trina Solar TSM-250PA05.18.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70030	12041-20000-05740	6300 N CANOGA AVE 2nd fl.	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.18492	-118.59722	NW portion of the 2 nd fl remodelEnergy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70031	15041-10001-21816	10828 S LOU-DILLON AVE	90059	15	088-5A215 174	6068004014	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM			PC Approved	07/30/2015 12:00:00 AM	ADDRESS	33.93727	-118.23473	EXPEDITED FEES FOR ROOF MOUNTED SYSTEM. (((PV 2, ROOF MOUNTED SOLAR, 3KW SYSTEM (1) INVERTER: PVI-3.0-OUTD-S-US-Z-A(14) MODULES: KYOCERA #KU2606XPAPERMIT FEES PAID UNDER APP. # 15041-90000-15136 (THIS APPLICATION FOR P.C ONLY))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70032	18041-20000-19734	16152 W COVELLO ST	91406	6	186B137    96	2205022015	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Issued	10/03/2018 12:00:00 AM	ADDRESS	34.20741	-118.48542	PV2.  Install 36KW AC System  roof mounted grid tied PV system  (108) PV modules with 3 inverters(12KW AC) connected to 125 A panel connected to 400A Service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70033	16041-10000-32292	1575 N GOWER ST 3RD-FLOOR	90028	13	148-5A189 330	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.09907	-118.32257	FULL PLAN CHECK,  INTERIOR TENANT IMPROVEMENT ON (E) OFFICE BUILDING LEVEL 3.  INSTALL (3) 200A PANELS. TOTAL AFFECTED AREA 9245 SQ.FT.((B# 16016-10000-03330)) NOTE. MULTIPLE FLOORS WERE REQUESTED PLAN CHECKED SEPARATELY BY CUSTOMER UNDER ELECTRICAL PLAN CHECK. Permit fee shall be under inspection and final fee is under 4th flr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70034	17041-10000-25459	585 S SANTA FE AVE	90013	14	126A217    91	5164007022	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.03893	-118.23078	PC for removal of HID fixturs and replace with new LED fixtures. T24 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70035	10041-10000-00867	3636 W BEVERLY BLVD	90004	13	138B197   449	5501009024	M1-1	Central	Wilshire	Rampart Village	YES	2111.10	Electrical	Electrical	Commercial			01/19/2010 12:00:00 AM	01/19/2011 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.07557	-118.28737	Plan check power and energy in existing high rise building. New 600A shunt trip equipment and elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70036	13041-10003-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			08/11/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  ((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70037	18041-20000-35474	5001-5007 N FIGUEROA ST	90042	1	150A225   181	5468004009	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.10521	-118.20218	"800A 240/120V 3ph-4w service upgrade for suites ""A"", ""B"", ""C"" & ""D"" and consolidation for (E) commercial building ."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70038	17041-10000-16345	6801 W HOLLYWOOD BLVD suite 147	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.10229	-118.33907	PC for power and energy for new footlocker TI. Scope includes adding new circuits, lights, one 45KVA , equipment, transformer, and four new panelboards.Total area 15277 sqft.Building # 17016-40000-11360	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70039	13041-10000-27864	9350 N NAGLE AVE	91331	6	198B153   473	2642011017	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	10/29/2013 12:00:00 AM	ADDRESS	34.24007	-118.4366	PV1 Plan check for roof mounted 2.5KW DC Photovoltaic System. Transformerless system. {SOLAREDGE SE3000A-US}]. [(10)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70040	13041-20000-31031	12744 N SAN FERNANDO ROAD	91342	7	222B145   323	2506003012	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	11/06/2013 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.30155	-118.46112	NEW DISTRIBUTION SECTION FOR EXISTING INSTALLATION. MANUFACTURING. NEW TRANSFORMER AND 600A RATED EQUIPMENT. PC FOR POWER ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70041	19041-10000-50311	953 N SYCAMORE AVE	90038	4	144B181   641	5531015014	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	03/20/2020 12:00:00 AM		Permit Finaled	07/06/2022 12:00:00 AM	ADDRESS	34.08865	-118.34299	PLAN CHECK FOR POWER AND LIGHTING. SCOPE OF WORK IS A TI (FIRST TIME) EXISTING 2500A SERVICE, 480/277 V, 3PHASE SYSTEM, THAT FEDS 3 NEW SUB PANELS, TOTAL AFFECTED AREA IS 2690.  PER BUILDING (Change of use from Motion Picture Production to Restaurant per ZA-2017-2814-CU-CUB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70042	18041-20000-22875	4529 N SHERMAN OAKS AVE	91403	5	168B145  1010	2283017006	C1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	02/07/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.15316	-118.46943	Plan check for power and energy. Project site is an existing commercial building. Project scope is 2nd floor addition and a tenant improvement. Work includes a new 400-amp service and a total lighting area of 5,405 sq. ft.Note: Building application has been generated under 16016-20000-27915	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70043	19041-20000-37080	11211 N SEPULVEDA BLVD lot #23	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 3.15 KW DC ROOF MOUNTED PV SYSTEM WITH (10) MODULES AND OPTIMIZERS AND (1) INVERTER(SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70044	13041-10000-27352	4554 N WORTSER AVE	91604	2	168B161   952	2362008001	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.1538	-118.41694	�Expedited plan check per applicant request�.No fees due . due to SB 1122  PV1 8.64KWAC 240V MICROINV 1STORY. nonSTD. ROOFMOUNT.[( 40) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: suntech STP255S-20WDB]. Main service panel being upgraded from 200A to 225A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70045	19041-20000-27941	21621 W CEZANNE PL	91364	3	165A105   116	2173004016	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Issued	07/19/2019 12:00:00 AM	ADDRESS	34.14644	-118.60278	PLAN CHECK FOR NEW 13.5 KWH ENERGY STORAGE SYSTEM TO EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK INCLUDES A 5KW TESLA POWERWALL AND A NEW 60A SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70046	18041-10000-10004	7850 N RUFFNER AVE	91406	6	189B137    54	2205009081	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.2142	-118.49665	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70047	17041-20005-40205	6927 N REMMET AVE #C	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	Revisions to approved set of plans.  Plans updated to match to (N) service configuration.  (((05/10/2018 Changes to an approved set of plans. All changes have been clouded. PV system has be redesigned. System size is 3.3 kWac and consists of (1) inverter and (9) modules. *****Previous Work Description*****Plan check for solar pv system, roof-mounted array on 3-unit apartment.3kW ungounded system. (9) 280W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70048	16041-20001-22010	11102 W MAGNOLIA BLVD	91601	2	171B173   615	2353005004	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.16478	-118.37263	Plan check for Title 24 only change of use from retail to restaurant in existing space. Total area:2,500 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70049	19041-10000-23649	17551 W MARGATE ST	91316	5	171B129    54	2257003041	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	09/18/2020 12:00:00 AM	ADDRESS	34.16774	-118.5159	Plan check for a PV1 5KW AC / 5.1KW DC roofmounted system adding on to an existing PV system. the scope includes (1) inverter, (17) modules and optimizer interconnecting through the main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70050	14041-20000-31853	4926 N ENCINO AVE	91316	5	168B129   105	2290004026	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.16013	-118.51402	PERMIT FEE $0.00 BY STATE SENATE BILL N0.1222Roof mounted PV system with optimizer.  Total system size is 18KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70051	18041-10000-42405	8615 S CENTRAL AVE	90002	9	097-5A209 325	6042023034	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	33.9596	-118.2566	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70052	14041-20000-15351	240 E 6TH ST	90014	14	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.0435	-118.24761	Title 24 plan chack for commercial office with total of 985 square footage.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70053	17041-20000-30078	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005902	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.01318	-118.34004	0$ permit fees due to senate bill 1222Plan check for a PV2 roof-mounted PV system. System size is 86 kWac and consists of (2) inverters, (342) modules, and (1) load center.building permit for PV on Roof # 17016-10000-24604Building permit for Medical office # 15010-10000-02476	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70054	19041-20000-52445	11620 W SHERMAN WAY	91605	2	183B169   146	2320001036	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	11/25/2020 12:00:00 AM		Permit Finaled	04/12/2021 12:00:00 AM	ADDRESS	34.20097	-118.38456	PV3.  Install 235.6 KW DC/212.647 KW AC CEC roof mounted PV system.  (589) modules with (9) 20 KW inverter, and a 400A panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70055	11041-10000-15425	926 S CROCKER ST	90021	9	124-5A211 165	5132002019	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			07/22/2011 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	10/24/2011 12:00:00 AM	ADDRESS	34.0355	-118.24971	New fire sprinkler monitoring system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70056	15041-10000-26848	11700 N CORBIN AVE	91326	12	216B113     1	2701002068		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Issued	09/01/2015 12:00:00 AM	ADDRESS	34.28162	-118.57177	PLAN CHECK FOR OUTDOOR LIGHTING FOR TRACT HOMES, TRACT 50509-01.  TOTAL SQUARE FOOTAGE 33430.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70057	19041-20000-20067	12036 W WILSHIRE BLVD	90025	11	126B145   162	4263003003	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2674.02	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	34.04435	-118.46687	ti to an existing commercial building.  changing all existing lighting to LED.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70058	17041-10000-35988	20835 W SHERMAN WAY	91306	3	183B109    23	2113013006	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.20126	-118.58735	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70059	14041-20000-20640	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	T24 plan check for externally illuminated 297 square foot sign.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70060	18041-20000-42098	725 S FIGUEROA ST 8th Floor	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM	12/24/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only. Project site is the 8th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 19,654 sq. ft.Note: Building application has been generated under 18016-10000-33224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70061	13041-10000-11350	24555 S FRAMPTON AVE	90710	15	039B197   136	7439020***	[Q]RD1.5-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	Apartment			05/02/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Expired	05/27/2015 12:00:00 AM	ADDRESS	33.80192	-118.29936	PV2 ROOF MOUNT 4.5 KW DC ON CONDO FOR 1301 HUNT TERRACE. INVERTER KACO BLUEPLANET 5002XI. 18. MODULES: MOTECH IM60B2-250-T10B45 . COMBINED SOLAR HEATING AND PHOTOVOLTAIC SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70062	12041-20000-26474	11546 W SHERMAN WAY	91605	6	183B169   691	2320001041	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	12/10/2012 12:00:00 AM		Permit Finaled	12/19/2012 12:00:00 AM	ADDRESS	34.20097	-118.38407	Central station monitoring system for a restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70063	17041-10001-05156	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	08/17/2017 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	Adding 22 new devices under Delta-5 only., updated battery calc. and volt. drop cal accordingly (Ref 16041-10000-36720 & 17041-10000-05156)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70064	10041-10001-21551	5400 N WILBUR AVE	91356	3	171B121    44	2161003009	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1394.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	01/11/2011 12:00:00 AM	ADDRESS	34.16894	-118.54453	14.45KW PHOTOVOLTAIC SOLAR SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70065	18041-10000-34167	10955 W MAGNOLIA BLVD	91601	2	171B173   554	2416004027	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1253.20	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Issued	09/07/2018 12:00:00 AM	ADDRESS	34.16508	-118.36956	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70066	18041-10000-22752	130 W BRUNO ST	90012	1	135A215   352	5409008016	[Q]C2-2-RIO	Central	Central City North	Los Angeles Historic Cultural		2071.03	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.06238	-118.23569	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70067	17041-20000-30191	10990 W WILSHIRE BLVD STE #1520	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.0577	-118.44711	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO OFFICES. 806 SQFT. HIGHRISE. SUITE #1520.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70068	19041-10000-18888	1438 N GOWER ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/20/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Issued	08/13/2019 12:00:00 AM	ADDRESS	34.09714	-118.32212	Power plan check for (2) 600-amp panels replacement with new load added, located in a (1) story commercial building.ALL EQUIPMENT BEING REPLACED MATCHES FLA TO ORIGINAL EQUIPMENT - NO NEW LOAD WAS ADDED TO THE SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70069	11041-20001-07963	11845 W OLYMPIC BLVD #  1240W	90025	11	123B149   453	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/31/2011 12:00:00 AM			PC Approved	05/31/2011 12:00:00 AM	PIN	34.03325831	-118.45191172	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR TI FOR SUITE #1240W	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70070	13041-20001-22377	1000 S HOPE ST	90015	14	127-5A207 343	5139008***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			Not Ready to Issue	10/21/2013 12:00:00 AM	ADDRESS	34.04346	-118.2617	PC FOR POWER. T24 ALREADY COMPLETED UNDER ORIGINAL APPLICATION. SUBWAY CONNECT TO EXISTING TRANSFORMER AND PANEL UNDER SEPERATE PERMIT. ((((((ORIGINAL PERMIT FOR EQUIPMENT UNDER APPLCIATION #13041-20000-22377)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70071	13041-10000-36213	6261 N WHITSETT AVE	91606	2	177B165   121	2332017013	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM	02/24/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.18485	-118.40542	PV1, INSTALL ROOF-MOUNTED SOLAR ARRAY , INTERCONNECT TO (E) 200A MAIN IN A 1-STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE IS 2.75 kW DC. (11)power  optimizers:Solaredge Op250-LV-MC4SM-2NA-Z   (11)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE3000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70072	18041-20001-28072	13646 W OSBORNE ST	91331	6	198B157   555	2625026003	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	ADDRESS	34.23862	-118.43052	VOID........................................pv1install roof mounted pv system sized 9.6KW AC interconnected with msp.(42) canadian soalr modules 295(42) IQ-6-60 microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70073	16041-10000-41573	505 S VIRGIL AVE #304	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM			PC Info Complete	11/28/2016 12:00:00 AM	ADDRESS	34.0649	-118.28724	Plan check for power and energy existing medical office #304. Total area: 910 sq ftB#16016-10000-27762	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70074	12041-20000-05664	6087 W SUNSET BLVD 4th Floor	90028	13	147A189    49	5545008002	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			PC Approved	03/13/2012 12:00:00 AM	ADDRESS	34.09819	-118.32178	T.I. to existing building on the entire 4th floor.  Install general/emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70075	18041-20001-06441	2449 N ARBUTUS WAY	90049	11	141B133   206	4492028019	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.08145	-118.50303	Expedited plan check.  PV1.  Install 9.72 kW (27 AC modules) PV system with battery backup and standby generator using Sonnen Battery System Eco 16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70076	14041-10001-17046	925 N LA BREA AVE	90046	5	144B181   708	5531016020	MR1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.08803	-118.34436	Change to approved set by adding a new 40HP elevator and (2) circuits on the floor plan. All changes are under delta-A only.(((5 story mixed use office, retail, and 2 level parking.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70077	14041-10000-07544	13323 W RIVERSIDE DR	91423	4	168B157   293	2359019008	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM			Reviewed by Supervisor	05/02/2014 12:00:00 AM	ADDRESS	34.15778	-118.42324	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR JOANN FABRICS IN A SHOPPING CENTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70078	10041-20002-13090	960 N LA BREA AVE	90038	4	144B181   634	5531015004	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Info Complete	11/14/2013 12:00:00 AM	ADDRESS	34.08868	-118.34386	"Modification to previously approved set of plans, adding under counter electric water heaters.  PLAN CHECK FOR CLOUDED ""DELTA 2"" CHANGES ONLY.<<<new plan check application  part paid on application # 10041-20000-13090, plan check is for power, lighting and energy.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70079	10041-20002-00691	2700 S FIGUEROA ST	90007	9	121-5A203 113	5123018031	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	05/31/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.02708	-118.27647	"Supplemental plan check to approved plan.  The revision includes ( D and and ""RFI0256) the addition of panel HGG to cover fan coils on each floor of the 5 floors.  Also replacing 2/0 feeders with 1/0 feeder (1/0) is suffecient per NEC.  The load after adding the fan coil is still below total servcie provided.  Supplementa permit could be pulled to cover new revision."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70080	15041-20000-18693	1055 S SERRANO AVE	90006	10	129B193   587	5080014003	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	10/12/2018 12:00:00 AM	ADDRESS	34.05106	-118.3065	New 20 unit apartment building. Plan check for power and energy. Adding new 1200A service. Total sqft. 19,388.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70081	11041-10000-08687	698 S VERMONT AVE	90005	10	132B197   187	5077010021	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM			PC Approved	05/02/2011 12:00:00 AM	ADDRESS	34.06011	-118.29144	single story existing restaurant, title 24 energy. and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70082	15041-20000-21617	22817 W VENTURA BLVD	91367	3	171B097   401	2042017033	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			07/08/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	PIN	34.1661322	-118.62401632	Title 24 plan check only.  Total area = 1,728 sq. ft.  T.I. to existing retail space.  New lighting, recepticles, appliances, and HVAC.  Total load < 400 amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70083	16041-10001-16751	8712 N NORRIS AVE	91352	6	195B173   571	2408011022	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM			PC Approved	06/03/2016 12:00:00 AM	ADDRESS	34.22738	-118.36986	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(40)MODULES-SOLARWORLD SW260(40)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE10000A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70084	15041-30002-28733	3003 W LEEWARD AVE 1-67	90005	1	132B197   281	5077017021	R4-2	Central	Wilshire	MacArthur Park		2122.03	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM			PC Approved	02/25/2016 12:00:00 AM	ADDRESS	34.05885	-118.28935	Changes to approved set.  Original plans showed distribution board with two busbars.  New plans show standard single busbar distribution board.  Feeder size reduced for one load.        PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE 90KW(291) CANADIAN SOLAR CS6XMODULES(3) SMA 24000TL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70085	12041-10000-13608	4541 N COLFAX AVE	91607	2	168B169   967	2364007043	[Q]RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Apartment			06/12/2012 12:00:00 AM	06/12/2012 12:00:00 AM		Permit Finaled	03/20/2013 12:00:00 AM	ADDRESS	34.15324	-118.38793	Plan check for installation of sprinkler monitoring system for new 12 unit town home building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70086	17041-10000-15923	5110 S NORMANDIE AVE	90037	9	111B197  1287	5017008033	C2-1L	South Los Angeles	South Los Angeles	Voices of 90037		2323.00	Electrical	Electrical	Commercial			05/12/2017 12:00:00 AM	05/13/2019 12:00:00 AM		Permit Finaled	02/28/2021 12:00:00 AM	ADDRESS	33.99647	-118.29998	PC for power and energy for a TI for laundermat (comm. building)New service 800A 120/240including new panels circuits and receptaclesTotal affected area 11015 sq.ftB#16014-10000-04768	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70087	17041-10000-41987	5517 S HOLMES AVE	90058	9	108B213   309	5105012029	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Closed	05/07/2018 12:00:00 AM	ADDRESS	33.99244	-118.24133	ENERGY PLAN CHECK FOR EXISTING BUILDING TITOTAL  EFFECTED AREA IS 9374 SQ FT.PORTION OF THE ELECTRICAL EQUIPMENT FEE IS PAID UNDER E#16041-20000-28116B#15016-20000-24505	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70088	16041-10000-13416	5800 W SUNSET BLVD TEMP	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Closed	08/02/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	CONNECTING 1600 TEMP SWITCHGEAR FOR CONSTRUCTION. TAPPING OFF EXISTING CUSTOMER OWNED TRANSFORMER. PERMIT INCLUDES NEW SWITCHGEAR, MANLIFTS AND MISC POWER EQUIP. THIS REVIEW IS PHASE 1 CONSTRUCTION ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70089	15041-10000-01452	9045 S LINCOLN BLVD	90045	11	096B161   823	4119039003	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Issued	01/16/2015 12:00:00 AM	ADDRESS	33.95667	-118.4165	Installation of new fire alarm system in existing college.  10 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70090	18041-10000-41173	3430 S 8TH AVE	90018	10	120B189   865	5044016045	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2190.20	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.02465	-118.32583	NEW 2.835KW ROOF MOUNTED PV SYSTEM WITH 9 PV PANELS ON ATHE ROOF OF A SINGLE FAMILY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70091	14041-10001-31792	3377 W WILSHIRE BLVD	90010	10	132B197    24	5502029021	(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			05/15/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	34.06193	-118.29742	Change to approved set by modifying the lighting plan. Note. All changes are under delta-3 only. (((T-24 plan check for the Restaurant. Total area: 2269 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70092	15041-10003-28019	9220 N WINNETKA AVE	91311	12	198B113   131	2761001072	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.23795	-118.57084	CHANGES TO APPROVED SET. PLANCHECK ONLY.  DELTA 19, 20 & 21 CHANGES .<<<<<<<Ti to an existing 2 story bldg full build out. Pc for power and energy.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70093	18041-20000-00857	3243 S LA CIENEGA BLVD	90016	10	123B173  1679	4205035002	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.02892	-118.3739	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,752 sq. ft.Note: Building application has been generated under 18016-10000-01072	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70094	17041-20001-36687	1225 N CHICKORY LANE	90049	11	141B137    99	4493025006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.08123	-118.48617	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.68 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70095	17041-10000-42736	8401 N VAN NUYS BLVD #15	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	03/23/2018 12:00:00 AM		Issued	03/23/2018 12:00:00 AM	ADDRESS	34.22308	-118.44896	T-24, PC for energy only. TI for an existing commercial space. Scope includes adding new lights for restrooms and corridor space within an existing tenant mall space. Total affected area is 4767 Sq. Ft. B#17016-10000-21521	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70096	14041-10000-25703	3521 E WHITTIER BLVD	90023	14	121-5A227 183	5188005022	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	09/14/2016 12:00:00 AM	ADDRESS	34.0265	-118.19771	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. FIRE DAMAGE REPAIR ON 1ST FLOOR COMMERCIAL .2685 SQFT, EMERGENCY LIGHTING.  2008 COMPLIANCE. BUILDING p # 14016-10000-11372.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70097	17041-20000-10020	6882 S ARIZONA AVE	90045	11	102B165   127	4110001028	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	33.97776	-118.39577	permit fee $0.00 by state senate fee no.122213.1 kw roof top single family	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70098	17041-30000-43952	439 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	33.77418	-118.27891	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 9,160 sq. ft.Note: Building permit has been issued under 17016-10000-29224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70099	14041-20001-19547	20028 W HEMMINGWAY ST	91306	3	189B113   774	2106022051	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM			PC Approved	09/24/2014 12:00:00 AM	ADDRESS	34.21389	-118.56972	fee charge is $0.00 by state senate bill no.1222revisions to an approved set of plans.  added (2) trina solar tsm-255 modules.PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTIMIZERS. USING STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70100	15041-10001-40939	2710 S SEVERANCE ST	90007	9	121-5A201  14	5123003411	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	34.02896	-118.28161	**4/14/16: Supplemental 2Design changed, is now 800A service 120/240V, 3phase,4W. New equipments added.PC FOR POWER ONLY, CHANGE OF USE FROM RESIDENTIAL TO A CHILD DAY CARE. SCOPE OF WORK INCLUDES A NEW 600AMP SERVICE, 3 NEW PANELS, LIGHTING AND RECEPTACLES. CONNECTED LOAD >400AMPS.NOTE: T-24 IS APPROVED ON THE MASTER PERMIT NUMBER 15041-10000-40939.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70101	13041-20000-10376	14932 W OXNARD ST	91411	2	177A149   115	2243022002	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM	04/25/2013 12:00:00 AM		Permit Finaled	08/14/2013 12:00:00 AM	ADDRESS	34.17921	-118.45867	Creating a new Office space within an existing Car Repair Garage.  Lighting only.  Load is less than 200 amps per applicant.  PLAN CHECK ONLY for Energy, NO Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70102	13041-10000-27706	229 W ANAHEIM ST	90744	15	030B205   352	7416032043	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	33.77999	-118.26462	e-permit to be pulled @ electrical plan check counter.. TITLE-24 PLAN CHECK; SCOPE OF WORK IS < 400A . TENANT IMPROVEMENT FOR SPEEDY-CASH IN A SINGLE-STORY COMMERCIAL BUILDING. WORK INCLUDES BOTH INDOOR AND OUTDOOR ILLUMINATION. EMERGENCY LIGHTS FED VIA EMERGENCY SOURCE (UNIT EQUIPMENTS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70103	19041-20000-49561	5067 N BAKMAN AVE	91601	2	171B173   956	2353014008	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			12/03/2019 12:00:00 AM			PC Approved	05/26/2021 12:00:00 AM	ADDRESS	34.16259	-118.37751	FULL POWER PLAN CHECK FOR A 1200 A, 120/240V, 3-PHASE 4-WIRE SYSTEM. SCOPE OF WORK INCLUDES TYPICAL UNIT PANELS, OTHER PANEL, SWITCHBOARDS, CIRCUITS, LIGHTING, AND CONTROLS.TOTAL AFFECTED AREA: 13600 SQ FT*APARTMENT UNIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70104	16041-10000-38879	11254 N TELFAIR AVE	91331	7	210B153   219	2616016017	R1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2016 12:00:00 AM	11/02/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	PIN	34.27465278	-118.43682052	PC FOR ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTER SYSTEM WITH 12 MODULES AND 3.8KW AC INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70105	15041-10000-13713	4415 S MAIN ST	90037	9	112-5A203  89	5110001037	CM-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.00329	-118.27425	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FIXTURES. TOTAL AREA 2048 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70106	15041-10000-13217	14724 W ERWIN ST	91411	6	178-5A149 183	2241015007	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			05/01/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.18342	-118.45407	NEW FIRE ALARM SYSTEM. 16 DEVICES AND 1 FIRE ALARM CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70107	12041-10004-30853	232 E 2ND ST	90012	14	129A213   468	5161024011	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM			PC Approved	09/09/2016 12:00:00 AM	ADDRESS	34.0495	-118.24258	Changes to approved set under delta 22 only. Removing one transformer and combining load from two units to one unit. Overall load is less than the previous approval. Permit is existing under master application number 12041-10003-30853.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70108	13041-10000-19159	735 S FIGUEROA ST SPACE #137	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	TITLE-24 PLAN CHECK ONLY.  RETAIL-RETAIL TENANT IMPROVEMENT, NEWLY CONNECTED LOADS LESS THAN 400AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70109	19041-10000-22908	3666 S MAIN ST	90007	9	117A205   126	5120012003	M1-1-CPIO	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM			Reviewed by Supervisor	07/17/2019 12:00:00 AM	ADDRESS	34.01578	-118.27382	Power plan check for an existing warehouse T.I. Scope inlcudes a new service of 600-Amp, single phase 120/240v, (6) new panel and ckts.(((T.I. TO EXISITNG URM BUILDING. PROPOSED NEW RESTROOMS, AND REMODEL TO EXISTING RESTROOMS. REMOVE EXISTING NON-PERMITTED NON-LOAD BEARING WALLS, AND CONSTRUCT NEWW NON-LOAD BEARING WALLS. REMODEL TO EXISTING PERMITTED MEZZANINES. (NO CHANGE OF USE) WORK TO COMPLY WITH NOTICE)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70110	17041-20000-31690	3019 E ASBURY ST	90065	1	147A217    68	5454031025	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM	01/24/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.09865	-118.23001	PV1. Install 5.85 kW roof mounted grid tied PV system.  (18) modules with 5kW rated string inverter.  13.5 kWh backup energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70111	17041-10000-35414	28100 S WESTERN AVE	90732	15	024B193   622	7442030207	P-1XL, [Q]C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2951.03	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Issued	10/03/2017 12:00:00 AM	ADDRESS	33.76429	-118.31012	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 10800 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70112	14041-10000-26393	613 S SPRING ST FIRST FLOO-R	90014	14	129A211   246	5144002016	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.04569	-118.25144	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE FROM LAUNDRY TO RESTAURANT.  HIGHRISE. 2000 SQFT.    EMERGENCY LIGHTING INSTALLED WITH 90 MIN BATTERY BACK UPS. BUILDING NOT PART OF GENERATOR RETROFIT. RESIDENTIAL OCCUPANCY NOT BEING CHANGED.  INSPECTOR TO VERIFY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70113	11041-10000-00378	20140 W SHERMAN WAY Building B	91306	3	183B113    63	2135038015	(T)(Q)C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM			PC Info Complete	04/21/2011 12:00:00 AM	ADDRESS	34.20085	-118.57213	general/emergency lighting for retail space of existing Public Storage building B.  splice existing feeder to new conductors from new MSB at the Jbox as shown on the single line diagram.  See building C plan for size of J Box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70114	18041-10000-23455	3060 W OLYMPIC BLVD STE 100	90006	10	129B193   321	5080030044	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.05239	-118.30229	TENANT IMPROVEMENT FOR BAKERY/RESTAURANT. FIRST TIME OCCUPANCY. PLAN CHECK FOR POWER AND ENERGY PER APPLICANT'S REQUEST. BLDG PERMIT # 18016-10000-16482	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70115	19041-10000-05457	6535 N LANKERSHIM BLVD	91606	2	180B169   715	2322020901	C2-1VL, R3-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.18962	-118.38798	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70116	13041-10000-13350	9075 N WOODMAN AVE	91402	6	195B153    73	2639032013	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	PIN	34.23444128	-118.44065672	PC FOR ENERGY ONLY. <400A. TI TO (E) BLDG. FROM RETAIL TO CHASE BANK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70117	18041-20000-45117	3144 N CORDA DR	90049	11	159B137   486	4490004049	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	03/23/2019 12:00:00 AM	ADDRESS	34.1296	-118.48812	Plan check for a PV1 roof-mounted PV system. System size is 21.78 kWdc/19.6 kWac-CEC and consists of (66) modules, (66) micro-inverters, (2) load centers, and (2) back-up batteries.$0 permit fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70118	18041-20000-35634	500 E TEMPLE ST	90012	14	130-5A215 303	5173009901	[T][Q]C2-2D-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	10/28/2018 12:00:00 AM	ADDRESS	34.05028	-118.23532	install by-pass feeders to (2) exisitng ups systems for maintenance.  no change in loads.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70119	16041-20001-35269	8818 N OAK PARK AVE	91325	12	195B133   293	2690011015	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/08/2016 12:00:00 AM	ADDRESS	34.23086	-118.50535	Expediter per applicant request.Plan check for the addition of PV system onto an existing PV1 roof-mounted PV system. System addition size is 3 kWac and consists of (1) inverter, (11) modules, and (1) load center. Total system size is 9 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70120	16041-20000-01652	10697 W SOMMA WAY	90077	5	144B149   173	4370006079	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM			Verifications in Progress	08/02/2017 12:00:00 AM	ADDRESS	34.09107	-118.45223	Plan check for power. Project site is a new 2-story, single family dwelling. Work includes a 600-amp service, (6) panels, and associated loads.Note: Building permit has been issued under 13010-10000-03127.  Electrical permit fees paid as part of building combination permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70121	19041-10001-52087	3300 N WONDER VIEW PZ	90068	4	157-5A183  25	5579034033	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM			Plans on Hold	02/24/2020 12:00:00 AM	ADDRESS	34.12792	-118.34149	EXPEDITED FEES____________________________NEW CENTRAL SOLAR SYSTEM USING SOLAR TILES WITH CENTRAL INVERTERS AND FOUR ENERGY STORAGE SYSTEMS. TOTAL SYSTEM SIZE IS 23.44 KWDC/18KWAC AND TOTAL SQ. FT. 1604.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70122	15041-10000-23907	2651 S HOBART BLVD	90018	8	123B193   848	5053011024	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.0311	-118.30806	NEW 2 STORY APARTMENT BUILDING 800 AMPS SERVICE.  PLAN CHECK FOR POWER AND ENERGY. FIRE VARIANCE NOT RQUIRED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70123	13041-20000-10442	1801 S CENTURY PARK EAST 20th Floor	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	06/28/2013 12:00:00 AM	ADDRESS	34.06201	-118.41537	Remodel to an existing elevator lobby on the 20th floor.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70124	14041-20001-10122	14605 W HIAWATHA ST	91345	7	207B149   874	2648013003	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.26015	-118.45065	EXPEDITE PER APPLICANT REQUEST(((PV1Install roof mounted solar array on SFD, interconnect with main panel. System size: 6.75kW1 transformerless inverter, 1 new branch circuit, 27 PV modules(1) SolarEdge #SE6000A-US-ZB-U    transformerless inverter(27) Canadian Solar #CS6P-250PX   pv modules)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70125	15041-10000-25557	425 S BROADWAY	90013	14	129A211    35	5149025001	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/07/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.049	-118.25009	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING. ADDING NEW LIGHTING. ADDING NEW PANELS. LOAD LESS THAN 50 kVA. PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY. TOTAL SQFT 3655.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70126	13041-10000-00796	3213 N FOND DR	91436	5	159B141   247	2293013029	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2013 12:00:00 AM	01/11/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.13311	-118.4838	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING SINGLE STORY UNIT. USING INVERTER - FRONIUS 1G - PLUS V 10.0. SOLAR PANEL - SUNNIA OPT260 - 60- 4 - 100. 13.52 KW SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70127	09041-10001-21469	5240 N LANKERSHIM BLVD	91601		171B173  1387	2350018086							Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.16613	-118.3751	revions to permitted set of plans -changes are shown clouded on the plans((((((((New 7-plex theater with office and retail space.  Plan check power and energy.  Modification to seperate fire alarm system has been filed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70128	16041-10000-34754	11928 S CENTRAL AVE	90059	15	084B209 - 728	6148014017	C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.00	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.9241	-118.25413	PV, NEW ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(6) MODULES:KYOCERA  KU2656ZPA(1)INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70129	14041-20000-22375	2169 N VALENTINE ST	90026	13	144A211    48	5420036001	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.09046	-118.2475	PV1.  Install 7 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70130	13041-10000-24655	1258 N HIGHLAND AVE	90038	4	144B185   132	5532005028	C2-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/09/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	05/22/2014 12:00:00 AM	ADDRESS	34.09419	-118.33842	INTERIOR ALTERATION OF 3-STORIES COMMERCIAL BUILDING; SERVBICE IS EXISTING;NEW PANEL BOARDSAND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70131	18041-10000-03051	4718 W WASHINGTON BLVD	90016	10	126B181  1160	5061016907	C2-1VL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2186.00	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.03962	-118.3421	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. PLAN CHECK T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70132	13041-10000-10414	14537 W ARCHWOOD ST	91405	6	180B149   115	2236009008	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.19306	-118.45004	This is a three story commercial mixed used. only the first floor title 24.  contractor pulling permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70133	11041-10000-04599	12448 W BRADDOCK DR	90066	11	108B157  1555	4221006058	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.10	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM	08/19/2011 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	33.98877	-118.41951	TWO STRORY ADDITION & RENOVATION OF EXISTING COMMUNITY CENTER/PRIVATE SCHOOL BULDING , NEW MULTI-PURPOSE ROOM, DISABLED ACCESSIBLE RESTROOM & OFFICE SPACE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70134	15041-20000-05765	11965 W ALLIN ST	90230	11	108B161   308	4218002907	R1-1, R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			02/27/2015 12:00:00 AM			PC Approved	02/27/2015 12:00:00 AM	ADDRESS	33.99187	-118.41297	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGHTING NEAR SPORTS COURTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70135	14041-10000-03974	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR GAP IN TOPANGA MALL. 1827 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70136	16041-30000-15527	2000 W 3RD ST	90057	1	135A205   280	5154028028	C2-1	Central	Westlake	Westlake North		2089.03	Electrical	Electrical	Apartment			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.06229	-118.27182	Plan check for a fire alarm system for a 4-story, 33-unit apartment building. System consist of (1) FACP, (1) annunciator, and (132) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70137	15041-20001-18447	3587 S OCEAN VIEW AVE	90066	11	114B153   664	4248025041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	09/08/2015 12:00:00 AM	ADDRESS	34.00879	-118.43601	EXPEDITE FEESPC FOR PV1 SFD. TOTAL SYSTEM SIZE 19.6KW AC USING 58 MODULES. TRANSFORMERLESS INVERTERS. TOTAL OF 4 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70138	19041-30001-14193	601 S FIGUEROA ST 26th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	05/02/2019 Changes to an approved set of plans. Scope of work has expanded to include the common area corridors. Total lighting area is now 2,135 sq. ft.*****Original Work Description*****Plan check for Title 24 only. Project site are the common area restrooms on the 26th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 520 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70139	19041-20000-09209	2100 N BEACHWOOD DR ev2	90068	4	151-5A189 322	5586012019	R3-1XL, RD1.5-1XL	Central	Hollywood	Hollywood United	YES	1895.00	Electrical	Electrical	Apartment			03/14/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.10865	-118.32131	addition of (8) EV chargers to an existing apartment building.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70140	17041-10002-41365	15121 W MONTE ST	91342	7	228B145   158	2502026050	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM			PC Approved	02/06/2018 12:00:00 AM	ADDRESS	34.32177	-118.46341	Supplemental for changes to approved to set. Relocating panels from residence roof to patio residence roof. PLAN CHECK ONLYNEW ROOF MOUNTED PV SYSTEM. CONSISTS OF 55 MODULES (HYUNDAI 300W HiS-S300RG) AND 2 INVERTERS(SOLAREDGE SE6000A-US and SE7600A-US)SYSTEM SIZE IS 16.5KWdc/13.6KWac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70141	18041-10000-44304	8526 N VAN NUYS BLVD	91402	6	192B149   118	2638001044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.22557	-118.44877	TITLE 24 ONLY FOR A TI OF AN EXISTING COMMERCIAL RETAIL SPACE. TOTAL SQ FT 1092.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70142	18041-10002-33164	108 S FREMONT PL WEST	90005	4	132B185   290	5090018010	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.05945	-118.32826	Expedite per applicant request.Change to approved set by changing the model of PV module and change microinverter to (2) central inverters.(((NEW ROOF MOUNTED 16.8 KW PV SYSTEM WITH 56 MODULES and MICROINVERTERS ON A SINGLE FAMILY HOME.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70143	15041-10000-24212	12822 W RANGOON ST	91331	6	198B161   332	2629027018	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.23786	-118.41235	NEW FIRE ALARM SYSTEM WITH (26) FA DEVICES AND ONE FA PANEL, AND ONE ANNONCIATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70144	15041-10000-42028	13355 W CANTARA ST	91402	6	192B157   783	2301001032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	12/15/2015 12:00:00 AM		Permit Expired	01/17/2018 12:00:00 AM	ADDRESS	34.21996	-118.42454	PV1, INSTALL 8.55 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (30) MODULES: SOLARWORLD 285 W MONO(30) MICRO INVERTER: ENPHASE M250	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70145	17041-10000-33183	5249 W CENTURY BLVD	90045	11	090B173    93	4128017044	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	09/02/2021 12:00:00 AM	ADDRESS	33.94558	-118.37196	TI IN AN EXITING HOTEL. INSTALL A NEW 100AMP PANEL, CIRCUITS AND LIGHTS ON THE 1ST & 5TH FLOOR (FITNESS RM). PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70146	19041-10000-51275	2901 E OLYMPIC BLVD	90023	14	120A223   115	5170023001	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Issued	12/12/2019 12:00:00 AM	ADDRESS	34.02251	-118.21532	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 134146 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70147	12041-10000-01814	651 S MISSION ROAD	90023	14	124-5A219  39	5171015902	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.03612	-118.22649	PLAN CHECK POWER AND ENERGY FOR AIR TREATMENT FACILITY (ATF) IN HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70148	13041-20000-25995	2048 N KENILWORTH AVE	90039	4	147A205   325	5431018019	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Expired	10/15/2015 12:00:00 AM	ADDRESS	34.09624	-118.26869	pv1 single family dwelling. total system size 2.5 kw AC using 12 modules. using enphase microinverter. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70149	12041-10000-29822	1925 S CENTURY PARK EAST suit   350	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/11/2012 12:00:00 AM			PC Approved	12/17/2012 12:00:00 AM	ADDRESS	34.06066	-118.41426	Title 24 and emergency lighting for 3rd floor of a high rise, partail floor TI suit # 350.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70150	17041-10000-06875	9911 S HOOVER ST	90044	8	091-5A199  74	6054007033	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	33.94602	-118.28712	PC for outdoor title 24 only. Removing HID fixutres with new LED fixutres. Area: 21,475 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70151	13041-10001-34516	2037 S LA CIENEGA BLVD	90034	10	126B173   885	4302034024	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM			PC Approved	07/16/2014 12:00:00 AM	ADDRESS	34.03915	-118.37756	"(((((6/12/14 Changes made to approved set.  Replace flourescent with LED)))))PLAN CHECK FOR POWER AND ENERGY TO (E)  SINGLE-STORY CHURCH. NEW 800A, 120/204, 3PH, 4WIRE MAIN SWITCHBOARD ""MS"" , 4 NEW PANELS, LIGHTING RENOVATION IS FOR INDOOR AND OUTDOOR TOTALING TO 39,203 SQ FT OF AREA.FA variance was submitted"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70152	16041-20000-38663	2481 S WALGROVE AVE	90066	11	108B153   151	4236009030	R1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	33.9951	-118.44495	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 7.6 kWac and consists of (1) inverter, (26) modules, (1) Tesla Powerwall, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70153	17041-20000-04639	10143 N WHITE OAK AVE	91325	12	204B129   314	2734004025	RS-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2017 12:00:00 AM	02/13/2017 12:00:00 AM		Permit Finaled	05/24/2017 12:00:00 AM	ADDRESS	34.25526	-118.52004	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD CENTRAL INVERTER PLAN. SYSTEM SIZE: 9.52 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70154	15041-20000-23261	5261 N CAHUENGA BLVD	91601	2	171B177   363	2416028024	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.16665	-118.36178	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70155	16041-20000-23299	5106 N MAMMOTH AVE	91423	4	171B157   798	2269001013	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	09/10/2016 12:00:00 AM	ADDRESS	34.16326	-118.4323	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.58 kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70156	14041-20001-02901	20209 W GRESHAM ST	91306	3	195B113   187	2781032027	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2014 12:00:00 AM			PC Approved	02/27/2014 12:00:00 AM	ADDRESS	34.23088	-118.57377	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.8 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70157	15041-10000-15279	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL-RIO, [Q]PF-1XL-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.18088	-118.48309	ADDITION OF (2) EXHAUST FANS INTO EXISTING DISTRIBUTION BOARD DS-13.ADDITION OF (2) RECIRCULATING PUMPS AND (1) NUTRIENT PUMP INTO EXISTING DISTRIBUTION BOARD MCC-PST.PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70158	15041-20000-15348	3712-3714 S KELTON AVE	90034	5	117B161   560	4252025033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Apartment			05/19/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.01778	-118.41289	Plan check for 16 appartment units with 800A service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70159	19041-20000-27932	19261 W CALAHAN ST	91324	12	198B117   193	2762017023	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	07/19/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.23666	-118.5524	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 4.845KW DC/4.357KW AC. SCOPE OF WORK INCLUDES (17) CERTAINTEED PV MODULES WITH P320 OPTIMIZERS, AND A SE3800H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70160	19041-10000-21031	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	34.07594	-118.35916	power plan check for a new 2000kW generator suppling a commerical building located  in a methane zone. Scope includes new source (generator) of power suppling a portion of the existing load for the building as standby power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70161	16041-10001-38993	10250 W SANTA MONICA BLVD 2705	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Changes to approved set noted under Delta-2; revise single line diagram, add circuits, revise load calculation. Tenant is ""Eataly"" in Westfield Century City."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70162	19041-10000-07834	777 S FIGUEROA ST STE 700	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Interior, non-structural tenant improvement to portion  of existing office suite.  .  No change in use, occupancy, or parking.PLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70163	13041-10000-33481	18555 W VENTURA BLVD #109	91356	3	174B125   543	2160007012	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.1697	-118.53779	Full plan check for power and energy. First time tenant. Remodel  dermatology store.Area 3500 sq ft. 2 panel 0-200A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70164	16041-10000-45767	1039 E 28TH ST	90011	9	118-5A209 305	5128023033	C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Apartment			12/30/2016 12:00:00 AM			Reviewed by Supervisor	01/09/2017 12:00:00 AM	ADDRESS	34.01707	-118.25606	FULL PC FOR POWER AND ENERGY FOR A NEW 6 UNIT APARTMENT BUILDING. SCOPE INCLUDES A NEW  600A 120/240V 1 PHASE 3 WIRE/DISTRIBUTION BOARD, NEW PANELS, NEW LIGHTS, AND NEW RECEPTACLES. PLAN INCLUDES TWO DIFFERENT TYPES OF TYPICAL PANELS FOR ALL UNITS. TOTAL AFFECTED AREA IS 7118 SQ. FT. B#16010-10000-05338	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70165	16041-10000-21001	1532 E 55TH ST	90011	9	108B213   252	5105016007	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	33.99288	-118.2465	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KW AC.(14)MODULES-CANADIAN SOLAR CS6P-265W(1)INVERTER-FRONIUS PRIMO 3.8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70166	14041-20001-09705	22733 W HAMLIN ST	91307	12	180B097   377	2038022011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.18904	-118.62235	Expedite fee only((PV1 system, roof-mounted on existing residential single unit with 24 modules and 6kw.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70167	19041-10000-41418	11100 W SANTA MONICA BLVD 20TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	03/25/2020 12:00:00 AM	ADDRESS	34.04726	-118.44465	T-24 PLAN CHECK FOR A TI TO INTERIOR RENOVATION OF EXISTING RESTROOMS. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 603 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70168	16041-10000-45404	1550 W 8TH ST	90017	1	130-5A205 151	5142018016	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.05213	-118.27207	PC FOR NEW FIRE ALARM SYSTEM FOR A NEW OFFICE BUILDING 1st THROUGH 4th FLOOR. SCOPE INCLUDES 263 FA DEVICES, AND 4 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70169	10041-10000-13588	5301 W WASHINGTON BLVD	90019	10	126B177   971	5064006001	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Public Safety Only			07/15/2010 12:00:00 AM	07/15/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	PIN	34.04061904	-118.35791755	new fire warning system for acharter school building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70170	18041-10000-17327	14940 W MANKATO ST	91345	7	210B149  1153	2615010010	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1094.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.26871	-118.45841	INSTALL A NEW ROOF MOUNTED 8.26 KW PV SYSTEM ON A SINGLE FAMILY HOME WITH 28 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70171	11041-20000-20226	7858 N VAN NUYS BLVD	91402	6	189B149   643	2212028035	[Q]C2-1-CDO, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			Plans on Hold	09/22/2011 12:00:00 AM	ADDRESS	34.21376	-118.44851	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70172	19041-20000-36589	22130 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Apartment			09/13/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	11/02/2021 12:00:00 AM	ADDRESS	34.18629	-118.60968	PV2.  PV roof mounted system, PV system size: 27.405KW DC, 24.4KW AC CEC with 63 PV Modules and 2 inverters(9KW and 14KW). Note: This is 12 buildings in 1 plan set.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70173	15041-10001-16419	11818 W WILSHIRE BLVD UNIT 300-PHASE 6	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Approved	01/20/2016 12:00:00 AM	ADDRESS	34.0474	-118.46308	PHASE 6:UPDATED POWER PLAN AND LIGHTING TO SHOW NEW TRANSFER ROOM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70174	13041-10000-02816	333 S HOPE ST BASEMENT	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			Corrections Issued	02/04/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLAN CHECK FOR TITLE 24. TENANT IMPROVEMENT ON A HIGH RISE. PARTIAL OF BASEMENT FLOOR. Plan check was done at van nuys application number 13041-20000-02989.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70175	18041-10000-30606	155 W MANCHESTER AVE	90003	9	097-5A203 310	6040011018	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	33.96025	-118.27578	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70176	14041-10000-24614	380 WORLD WAY T86	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	12/09/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED  TENANT IMPROVEMENT FOR FOOD & BEVERAGE CONCESSION (300 SQFT) ON  EXISTING SHELL SPACE AT LEVEL 1. coffee bean and tea leaf. PC FOR POWER AND ENERGY FOR FIRST TIME OCCUPANCY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70177	18041-20000-32869	515 S FIGUEROA ST 15TH FLR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for Title 24 only in existing elevator lobby and corridor 15th Floor in existing high rise building . Total area: 1576 sq ft. B#18016-10000-12463	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70178	18041-10000-43495	1028 S SEASIDE AVE	90731	15	015B205    18	7440032904	M3, [Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	33.73466	-118.26899	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70179	19041-20000-31984	6650 N VAN NUYS BLVD	91405	6	180B149   241	2237001010	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.19215	-118.44845	Plan check for new Fire alarm system for existing building new fire alarm device: 22 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70180	10041-10000-14502	1875 CENTURY PARK EAST Suite#1380	90067	5	132B161    11	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2010 12:00:00 AM			PC Info Complete	07/27/2010 12:00:00 AM	PIN	34.06139196	-118.41527843	TI IN AN EXISTING OFFICE AREA IN SUITE #1380.    PLAN CHECK IS FOR TITLE 24 ENERGY ONLY. PERMIT IS FOR NEW CIRCUITS. VARIANCE FORM WAS SUBMITTED TI SEPARATE THE FIRE LIFE SAFETY SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70181	16041-10000-43139	5440 N TOPANGA CANYON BLVD	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	10/11/2017 12:00:00 AM	ADDRESS	34.17004	-118.60552	Plan check for Title 24 only in existing space T.I. in Bank of America. Total area: 5,410 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70182	16041-30000-20841	11661 N GLADSTONE AVE	91342	7	213B165   270	2531022017	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.28202	-118.39754	Plan check for the addition of a PV1 system onto an existing PV1 roof-mounted PV system. Addition system size is 3 kWac for a total system size of 10.6 kWac. System addition consists of (1) inverter and (7) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70183	18041-10000-15889	5913 W 75TH ST	90045	11	102B169   244	4104009014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	33.9733	-118.38645	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL-TOP. TOTAL SYSTEM SIZE IS 2.40KWdc / 2.24KWac. THE PV SYSTEM IS PART OF LADWP SOLAR COMMUNITY PROGRAM. PV SYSTEM IS INTERCONNECTING TO A PERFORMANCE METER. (8)MODULES-SOLARWORLD  SW-300(8)OPTIMIZERS-ENPHASE S280--60-LL-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70184	18041-10000-10111	340 N MADISON AVE	90004	13	138B197   117	5501002033	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Issued	04/19/2018 12:00:00 AM	ADDRESS	34.07748	-118.28901	NEW 480/277V 2500A SERVICE AND SWBD TO SUPPLY AN EXISTING OFFICE BUILDING AND THREE FUTURE BUILDINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70185	10041-10000-17952	14006 W RIVERSIDE DR Suite# 273	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/10/2010 12:00:00 AM	10/22/2010 12:00:00 AM		Permit Finaled	11/22/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	"Change of use to a new ""Radio Shack"" in the mall in space # 273 on the 2nd floor. Plan Check is power & energy.  Building Permit # 10016-10000-16533."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70186	13041-10000-32171	12879 W RUNWAY ROAD UNITS 1-3-BLDG 5	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			11/26/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	33.97525	-118.42037	INSTALLATION OF A NEW FIRE ALARM SYSTEM for a 4 story residential building (Building 5). THIS IS BUILDING 5 OF 6.  THE FACP IS ON BUILDING # 2. There are two building types for the site. Building 5 plan is type 3 ( SIGNIFYING 3 PLEX ).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70187	14041-20000-18522	4560 N ENSENADA DR	91364	3	166-5A107  19	2190015058	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/09/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.15203	-118.59727	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(14) TRINA SOLAR TSM-255 MODULES(1) SOLAR EDGE SE3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70188	18041-20000-33264	13444 W VENTURA BLVD	91423	4	165B157   811	2373007003	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.14704	-118.4264	Plan check for Title 24 Energy only in existing space T.I. retail. Total area: 983 sq ft. B#18016-10000-17234	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70189	19041-30000-08874	601 S FIGUEROA ST 13th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is common area restrooms on the 13th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 520 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70190	16041-10001-04433	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM			PC Approved	03/20/2017 12:00:00 AM	ADDRESS	34.01318	-118.34004	03-14-2017 Changes to an permitted set of plans, Changes include relocate smoke detectors and duct detectors and change from conduit to plenum wire. Changs apply to delta D only. Plan check only. {{{{PC for a new fire alarm system to a New 4-story Kaiser Permanente Medical Office Building. Scope includes 487 FA devices, 1 FA panel, and 1 Comm. panel. }}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70191	14041-10000-25414	1737 N LAS PALMAS AVE 1-82	90028	13	148-5A185  43	5547010004	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			09/16/2014 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.1026	-118.33639	New 6 story 82 unit apartment building using old codes. Building approved in 2013.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70192	16041-20000-42737	7014-7016 W SANTA MONICA BLVD	90038	4	144B181   487	5532030004	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/06/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.09056	-118.34217	TI TO AN EXISTING COMMERCIL BUILDING TWO STORY.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 2703.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70193	16041-20000-30477	17242 W PRAIRIE ST	91325	12	198B133   305	2692005008	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.23932	-118.51023	"""$0 permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 16.350 KW"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70194	10041-20000-15696	1999 S AVENUE OF THE STARS	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	01/27/2011 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI IN OFFICE BUILDING ON 16TH FLOOR. P/C IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70195	14041-10000-23290	10226 N AMBOY AVE	91331	7	204B157   575	2646023025	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.25619	-118.42629	Installation of roof mounted solar system.  System size = 5 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70196	15041-10000-17391	15857 W STRATHERN ST	91406	6	189B141    30	2206005023	C4-1VL, M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Permit Finaled	07/07/2016 12:00:00 AM	ADDRESS	34.21581	-118.47928	FULL PC FOR POWER AND ENERGY. EXPANSION AND REMODELING OF AN EXISTING COMMERCIAL BUILDING. TOTAL SQ. FT.96,554 .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70197	13041-10000-13944	2121 S AVENUE OF THE STARS Suite 2100	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.05554	-118.41342	PERMIT TO BE PULLED AT EPC COUNTER ONLY. PC FOR ENERGY ONLY. less than 400A connected load. hirise 21st floor. done by owner for corridor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70198	13041-10000-14395	100 S SAN PEDRO ST STE100	90012	14	130-5A213 169	5161017035	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	ADDRESS	34.05008	-118.24084	PC FOR ENERGY ONLY. TI TO (E) BLDG. part of 5 story building.  1620 SQ FT OF NEW TENANT IMPROVEMENTS FOR CHASE BANK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70199	13041-10000-28363	5424 N GENTRY AVE	91607	2	174B165  1006	2348011005	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.16933	-118.39309	PV1. ROOF MOUNTED SOLAR ARRAY. NON STANDARD PLAN.TRANSFORMERLESS UNGROUNDED SYSTEM.(21) TRINA SOLAR # TSM-250PA05.18(1) SOLAREDGE # SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70200	17041-10000-35958	1461 W DANA ST	90007	8	123B197   997	5054028900	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.03168	-118.29341	REPLACE EXISTING HID FIXTURES WITH NEW LED FIXTURES - T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70201	19041-10000-23950	222 W 109TH PL	90061	8	088-5A203 205	6074014034	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Issued	06/21/2019 12:00:00 AM	ADDRESS	33.93642	-118.27705	New PV1 roof mounted system, system size is 3KWac/2.75KWdc. Scope of work is nine modules (candian solar 305) with optimizers (P320) and a central inverter ( SE3000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70202	14041-10003-32844	8424 W BEVERLY BLVD	90048	5	138B173   491	5511012002	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.07583	-118.37407	changes to an approved set. changes include two new fixtures, the splitting of an 800amp switchgear to two 400amp distribution boards. note changes on delta 8 and 9. (((Minor revisions to approved set.  Change of lighting fixture and relocation of fixtures.  Delta 7 revisions.)))(((T24 and power plan check.  Existing restaurant being split into two new restaurants.  Installing new transformer with 2 new meters and disconnects. Area = 1849 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70203	14041-20000-01390	13031 W JEFFERSON BLVD SUITE 800	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	33.97451	-118.42531	PC FOR T24 ENERGY ONLY. NEW CONECTED LOAD LESS THAN 400A. PC FOR NEW LIGHTING ONLY. TOTAL AREA ABOUT 10K SQ FT. WORK DONE IN SUITE 800A AND B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70204	16041-10003-28773	20500 S DENKER AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	33.84481	-118.30379	PC FOR CHANGES TO APPROVED SET UNDER DELTA 6. SCOPE INCLUDES REMOVAL OF FIRE PUMP CONTROLLER AND CONTROLLER TRANSOFORMER AND ADDITION OF CIRCUIT TO FEED THE FIRE PUMP CONTROLLER. THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70205	14041-20000-31050	10036 N LASAINE AVE	91325	12	204B129   444	2734030018	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.25319	-118.51217	New roof mounted PV system, total system size 8.5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70206	11041-10000-13337	12001 W CHALON ROAD # 402	90049	11	141B141     5	4429003027	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01, 2623.02	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	08/08/2011 12:00:00 AM	ADDRESS	34.08469	-118.4849	renovation of  classroom  402 in the Humanities Buildingplan chk is for title 24 ; permit fee is in Inspection Fee period	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70207	16041-10000-27852	1846 S ROBERTSON BLVD	90035	10	126B169    62	4303006015	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.02	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	09/03/2016 12:00:00 AM	ADDRESS	34.04533	-118.3863	Plan check for T-24 only. Change of use from SFD to a Day Care center. Install new lights, receptacles, and (1) 200A panel (service upgrade to 200A).  Total affected area: 1,489 sq.ft.  (B# 16016-10000-09999)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70208	16041-20000-11659	20513 W QUEDO DR	91364	3	169-5A111  64	2166023008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	06/29/2016 12:00:00 AM	ADDRESS	34.15891	-118.5797	Plan check for the addition of a 3 kWac PV1 PV system onto an existing PV system PV addition consists of (1) inverter, (17) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70209	19041-20002-25127	10074 W SULLY DR pv1	91352	2	189B181    75	2403019012	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM			PC Approved	07/31/2019 12:00:00 AM	ADDRESS	34.218	-118.34978	Revisions to approved set.  Addition of a 125A load center and performance meter to system design.  Approval for clouded and initialed details only.  (((pv1 plan check for installing a roof  mounted pv system on existing sfd. system size is 12.685 KW DC/11.4KW AC with (1) 5KW ESS interconnected with msp. scope of work includes (43) solar world pv modules with P320 optimizers, a SE3800H inverter, a SE7600A inverter, a LG Chem RESU10H battery, and a 60A load center)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70210	13041-10001-32028	3969 N GOODLAND AVE	91604	2	162B161   292	2384018028	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			PC Approved	04/25/2014 12:00:00 AM	ADDRESS	34.14235	-118.4107	Expedited rooftop solar plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70211	14041-20000-35218	3418 N PUEBLO AVE	90032	14	142-5A235 122	5218016025	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	PIN	34.08543054	-118.17390482	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4KW. (16) HUYINDIAY MODULES(16) ENPHASE MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70212	15041-20000-37128	1656 N ORANGE DR	90028	13	147B181   268	5548006010	PB-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM			PC Info Complete	11/17/2015 12:00:00 AM	ADDRESS	34.10076	-118.34127	"PC for Energy only, Total area: 3460 sq.ft.""Orange Drive Garage""NEW DROP CEILING PANELS AT ELEVATOR LANDING AREAS AND REPLACEMENT OF CANOPY ATTACHED TO ELEVATOR & STAIR SHAFT ENCLOSURES AT ROOFTOP OF ( E ) PARKING STRUCTURE ."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70213	14041-10001-17173	13131 W NIMROD PL	90049	11	129B137   291	4407011013	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.05105	-118.49622	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 7.905 KW DC ROOF-MOUNTED SOLAR ARRAY ON TWO-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(31) MODULES: TRINA SOLAR TSM-255PA05.18(2) TRANSFORMERLESS INVERTERS: AURORA PVI-3.6-OUTD-S-US-Z-A &PVI-3.0-OUTD-S-US-Z-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70214	13041-10000-14058	6600 N TOPANGA CANYON BLVD UNIT 1092	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	07/15/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ON AN EXISTING TENANT SPACE (LEGO STORE) UNIT #1092. 2435 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70215	10041-20000-24995	8941 N TAMPA AVE 101-103	91324	12	195B117    25	2783028054	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1133.01	Electrical	Electrical	Commercial			12/15/2010 12:00:00 AM	12/15/2010 12:00:00 AM		Permit Closed	11/19/2012 12:00:00 AM	ADDRESS	34.23285	-118.55413	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70216	12041-10000-18899	330 N LA CIENEGA BLVD	90048	5	138B173   291	5514012006	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.07697	-118.3764	NEW ALARM SYSTEM FOR AN EXISTING COMMERCIAL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70217	17041-20002-12060	7501 N GLENOAKS BLVD	91504	2	186B181   296	2401042013	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.04	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM			PC Approved	09/13/2018 12:00:00 AM	ADDRESS	34.20677	-118.34209	Revisions to approved set of plans to reflect field revisions.  Revised pool area and roof lighting.(((2/23/2018chnages to an approved set of plans.  changes to reflect field conditions.  changes noted delta 1.this is plan check only.  no new equipment.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70218	15041-20002-18966	3733 S MOTOR AVE	90034	5	120B165  1312	4314003036	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM			PC Approved	08/21/2015 12:00:00 AM	ADDRESS	34.02181	-118.40526	Changes to approved set.  Reducing transformer from 45 kVA to 30 kVA.  Reducing wire size on AC size from #1 AWG to #6 AWG.****** Plan check for a PV2 roof-mounted PV system. System size is 18 kWac and consists of (2) inverters, (100) modules, (100) power optimizers, (1) load center, and (2) combiner boxes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70219	14041-20000-12488	19120 W ERWIN ST	91335	3	177B121   244	2128024015	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	06/25/2014 12:00:00 AM	ADDRESS	34.1839	-118.54922	pv1 install roof mounted pv system sized 4.5kw interconnected with main panel.  (1) transformerless inverter model #solaredge se500A with power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70220	17041-10001-41271	7902 N ALLOTT AVE	91402	6	189B157   580	2301022016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM			Reviewed by Supervisor	11/20/2017 12:00:00 AM	ADDRESS	34.21408	-118.4275	Supplemental for PV expedite fees.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70221	17041-10003-21151	3321 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			02/12/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.0275	-118.3723	"SUPPLEMENTAL FOR CHANGES TO AN APPROVED SET. ALL CHANGES ARE CLOUDED UNDER DELTA ""R1"" & ""R2"".CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70222	11041-10000-15754	850 S BLOOM WALK 203-205	90089	9	120A201    79	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM			PC Approved	08/08/2011 12:00:00 AM	PIN	34.02212933	-118.28350631	T.I.  Remodel of light fixtures on the second floor (suites 203 thru 205) of a three story building.  Plan check is for energy and emergency lights only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70223	10041-10003-12657	263 WORLD WAY	90045	11	087B165    13	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM			PC Approved	07/11/2013 12:00:00 AM	ADDRESS	33.94461	-118.40469	Revisions to permitted set of plans:changes bubbled and noted on sheets E201; B-E010;E251;FROM EXISTING MDP, NEW FEEDERS TO PANEL LP4 WHICH WILL SUPPLY EQUIPMENT TO PROVIDE POWER AND LIGHT FOR TWO MOBILE DWP SUBSTATIONS FOR CONSTRUCTION.  LOADS ON PANEL LP4 INCLUDES A 15KVA UPS(PWR & LIGHTING FOE TRAILER/SUBSTATIONS) AND TWO SETS OF FEEDERS  TO SUPPLY POWERS TO FANS COOLING THE SUBSTATIONS XMRSNEW UNMANED ELECTRICAL METER BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70224	17041-10000-07358	6600 N TOPANGA CANYON BLVD STE 2046	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	07/08/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only in existing space T.I. retial. Total area: 2,199 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70225	14041-20002-02150	4934 N LOUISE AVE	91316	5	168B133   119	2289008015	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2014 12:00:00 AM			PC Approved	06/04/2014 12:00:00 AM	ADDRESS	34.15952	-118.50964	(($0 plan check fee due to senate bill 1222 from 2012)))delta changes clouded A. change in inverter location and change in wire size	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70226	14041-20000-11765	12422 N LUNA PL	91344	12	219B133   433	2608020005	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.2964	-118.50795	PV1. ROOF MOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE:2.7 KW DC.(10) SUN EDISON 270W MODULES(10) ENPHASE MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70227	18041-20000-34477	3720 N LITCHFIELD LANE	91356	3	162B117   401	2177043011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Issued	09/18/2018 12:00:00 AM	ADDRESS	34.13655	-118.55193	PV1.  Install 21.45 kW roof mounted grid tied PV system.  (66) modules with (2) 10 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70228	17041-30000-46218	6411 N SEPULVEDA BLVD #2H	91411	6	180B145   763	2234016013	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.18729	-118.46647	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 1,600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70229	11041-10000-14729	609 S GRAND AVE	90017		129A209    68	5144005022							Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	07/18/2011 12:00:00 AM	ADDRESS	34.04858	-118.25572	TI TO AN EXISTING RESTAURANT IN A HIGH-RISE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.  PERMIT #11041-20000-15153	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70230	17041-20000-08439	21550 W OXNARD ST Suite 100	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for energy only. TI to office suite 100 in existing high rise building. New lighting (incl. emergency). 3,403sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70231	11041-10000-10961	2106 W TEMPLE ST	90026	13	136-5A205  32	5157017028	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.00	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM	05/27/2011 12:00:00 AM		Permit Finaled	07/18/2011 12:00:00 AM	ADDRESS	34.07024	-118.26853	TI IN AN EXISTING MINI MART STORE SECTION OF ARCO GAS STATION (NON HAZARDOUS AREA). PLAN CHEK FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70232	19041-10000-39594	1411 W 190TH ST Suite 660	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	33.85852	-118.30317	PLAN CHECK ONLY FOR ENERGY ONLY, SCOPE OF WORK IS INSTALLING LIGHTS IN AN OFFICE SPACE. TOTAL AFFECTED AREA IS 2051 SQFT. NOTE PERMIT FEES HAVE BEEN PULLED UNDER 19041-40000-25253	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70233	17041-10000-09788	19191 S VERMONT AVE 8th Floor	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC FOR ENERGY ONLY. ELEVATOR LOBBY REMODEL. T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70234	12041-20000-19992	18705 W VENTURA BLVD	91356	3	174B121   514	2160002005	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM			PC Approved	08/23/2012 12:00:00 AM	ADDRESS	34.17095	-118.54095	T.I. to existing bank (Chase) in the office area.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70235	18041-20000-00604	515 S SHATTO PL 1st Floor	90020	13	135B197   842	5077003010	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.0646	-118.29014	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 767 sq. ft.Note: Building application has been generated under 17016-10000-37769	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70236	11041-20000-17765	127 S SAN VICENTE BLVD Bulletin-89	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 89 plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70237	16041-10001-25327	660 S FIGUEROA ST # 1890	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Approved	07/26/2016 12:00:00 AM	ADDRESS	34.04953	-118.25947	07/26/16Changes to an approved set of plans. All changes are made under delta 1. Changes include adding emergency lights to floor plans. Changes to reflect what is on the field per inspector request. note: Permit is paid under PCIS#16041-10000-25327(((((Plan check for energy only to offices in suite 1890 for commercial building. Adding new lighting and power for receptacles. Total sqft = 1293. B#16041-10000-25327	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70238	16041-20001-38213	17755 W ALONZO PL	91316	5	165B129    33	2182025011	RA-1	South Valley	Encino - Tarzana	Encino	Yes	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM			PC Approved	10/29/2016 12:00:00 AM	ADDRESS	34.15233	-118.52	Plan check for a PV1 roof-mounted PV system. System intercontects with a 400-amp MSP and size is 10 kWac. System consists of (1) inverter and (44) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70239	17041-20001-05148	815 W COLORADO BLVD 2nd Floor	90041	14	163-5A231 107	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM			PC Approved	03/06/2017 12:00:00 AM	ADDRESS	34.14051	-118.18382	Plan check for Title 24 only. Project site is the second floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,766 sq. ft.Note: Building permit has been pulled under 17016-10000-00387	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70240	13041-10000-17638	12875 W RUNWAY ROAD Units 1-6	90094	11	102B157   393	4211033034	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			07/03/2013 12:00:00 AM	12/10/2013 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	33.97528	-118.42029	PLAN CHECK POWER AND ENERGY FOR NEW 6-UNIT MULTI-FAMILY CONDO BLDG W/ATTACHED GARAGE. 4 STORY BUILDING. BUILDING #4  MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70241	16041-10000-07120	12130 W MILLENNIUM	90094	11	105B161  1205	4211010053	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/29/2016 12:00:00 AM	03/14/2016 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	33.98008	-118.40646	METEANE GAS DETECTION SYSTEM LEVEL3. ADDITION 7 NEW SENSORS. 3 STORY COMMERCIAL BUILDING. T.I.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70242	12041-10000-15047	1801 E 50TH PL	90011	8	111B193  1144	5015007003	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	11/12/2013 12:00:00 AM	PIN	33.99769208	-118.31184699	New 271.4KW roof mounted photovoltaic system for a commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70243	10041-20000-03713	3650 W MARTIN LUTHER KING, JR BLVD SPACE 166-168	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	04/12/2010 12:00:00 AM		Permit Finaled	05/20/2010 12:00:00 AM	ADDRESS	34.01118	-118.33649	T.I WORK IN CRENSHAW PLAZA MALL. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70244	12041-10000-01357	5347 S 4TH AVE	90043	8	108B189   528	5006030036	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			01/19/2012 12:00:00 AM			PC Approved	02/06/2012 12:00:00 AM	ADDRESS	33.9937	-118.32164	New 'flex building' at O'Donovan's Middle School.  New load is 175A.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Full plan check may be required subject ot field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70245	15041-20003-04586	20131 W PRAIRIE ST	91311	12	198B113   121	2748038033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	34.2394	-118.57264	01-26-16 Change to approved set of plan; Changes include inverter feeding Emergency lights to Emergency Unit equipment. changes apply to delta 8 only. *************************************************************************12/16/15Changes to an approve set of plans. All changes made under delta 7.  Scope includes adding new car charge stations, new track lights, and an inverter for emergency egress lighting.[[06-05-15 Change to  approve set of plan. Changes include addition of panel P1 to the MSB for car chargers]][[[[[TI TO AN EXSTING OFFICE COMMERCIAL BUILDING.  NEW STANDBY EQUIPMENT, PANELS, TRANSFORMERS AND CIRCUITS.  SCOPE OF WORK TO BE PERFORMED IN FIRST SECOND AND THIRD FLOOR.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 32225.]]]]]*****************************************************************************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70246	17041-20001-19660	11500 W CANTON DR	91604	2	159B169   378	2377016014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	34.13274	-118.38388	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with AC coupled battery backup system.10.4kW ungrounded system. (37) 325W pv modules. (2) 5kW Tesla Powerwalls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70247	18041-20000-45052	23129 W ERWIN ST	91367	3	177B097   211	2039010025	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	PIN	34.1834495	-118.63072214	Plan check for PV roof mounted system, system size: 11.39kW with 34 PV Modules and 34 micorinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70248	13041-10002-32334	5448 W HOLLYWOOD BLVD	90027	13	148-5A193 151	5544021910	[Q]C2-2D	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.10157	-118.30874	Change to approved set by modifying the lighting plan. All changes under delta-E1 only.(((TI  for commercial part of a mixed used  building, total area 4664 sq ft.4 story.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70249	17041-10000-12130	7161 WORLD WAY WEST	90045	11	090B161    67	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	33.94524	-118.41969	PC FOR TAXIWAY EXPANSION. PROVIDING 3 NEW CIRCUITS FROM POWER REGULATOR TO SERVE TAXIWAY LIGHTING. THIS IS FOR TAXIWAY T. CIRCUITS RATED 5KV MAXIMUM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70250	15041-10000-38348	7860 W SUNSET BLVD	90046	4	147B177  1002	5551026024	C4-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	05/12/2016 12:00:00 AM	ADDRESS	34.0979	-118.36081	PC FOR ENERGY. T.I FOR RESTURANT.  TOTAL AREA 1358 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70251	18041-20000-03782	11970 W FOOTHILL BLVD	91342	7	210B165    11	2532012044	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/07/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	34.27628	-118.39733	Change of use from retail to massage parlor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70252	11041-10000-07479	1605 N CAHUENGA BLVD	90028	13	148-5A187 315	5546007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/13/2011 12:00:00 AM			PC Approved	04/13/2011 12:00:00 AM	ADDRESS	34.09994	-118.32968	T.I. TO AN EXISTING OFFICE SPACE.  T-24 WITH EMERGENCY LIGHTING.  OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70253	14041-20000-24867	7006 S HOOVER ST UNIT 8	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #8.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70254	11041-10006-02930	1717 N GARFIELD PL 1-90	90028	13	148-5A193 110	5544003002	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Apartment			10/12/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	ADDRESS	34.10227	-118.31103	Delta eleven modification:  Change RDB1 and  RDB2 to service entrance conductors, and provide service rated disconnects at the residential metering sections.  Revise elevation drawings to shown disconnects at the metering sections.  No change in loads.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70255	17041-10000-14423	8358 N REMY AVE	91306	3	192B109   585	2781027010	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2017 12:00:00 AM			Corrections Issued	05/02/2017 12:00:00 AM	ADDRESS	34.22166	-118.57823	PC for roof mounted pv Total system size of 3.85 kwACSystem includes 14 moudules and optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70256	16041-20001-29048	225 N CAROLWOOD DR	90077	5	141B157   408	4358005027	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2016 12:00:00 AM			PC Approved	08/23/2016 12:00:00 AM	ADDRESS	34.08188	-118.42612	EXPEDITE PER APPLICANTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70257	17041-10000-18423	17412 W CHASE ST	91325	12	192B129   220	2787018003	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	10/18/2017 12:00:00 AM	ADDRESS	34.22318	-118.51281	PC FOR ROOF MOUNTED PV SYSTEM CENTRAL INVERTER (2) W/ OPTIMIZERS.SYSTEM SIZE 13.6KWAC (SE6000 AND SE7600)47 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70258	12041-10000-17184	4121 N SUNNYSLOPE AVE	91423	5	165B157  1075	2373010012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2012 12:00:00 AM	07/24/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.14501	-118.42729	Plan check for new roof mounted 7.04KW photovoltaic system. Single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70259	16041-20001-40274	818 S BERENDO ST	90005	10	132B197   595	5094013022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.05708	-118.29399	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 30kW (6kW*5) ungrounded system. (110) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70260	13041-10000-02277	6600 N TOPANGA CANYON BLVD # 1014	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/29/2013 12:00:00 AM			PC Approved	01/29/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	TENANT IMPROVEMENT AT THE GAP STORE AT THE TOPANGA MALL-ADDITION OF NEARBY VACANT TENANT SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70261	16041-20000-18010	17330 W SEPTO ST	91325	12	201B129    29	2734031017	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.25126	-118.51221	PV1.  Install 13 kW DC roof mounted PV system.  (50) 260 W modules with (1) 11.4 kW transformerless central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70262	10041-20000-05695	6831 N VINELAND AVE	91605	2	183B173   213	2319005022	M1-1VL, M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Expired	11/29/2012 12:00:00 AM	ADDRESS	34.19523	-118.37056	NEW 1200A service to fire damage bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70263	18041-10000-39989	7300 WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	03/06/2020 12:00:00 AM		Permit Finaled	09/24/2021 12:00:00 AM	ADDRESS	33.93972	-118.42295	REPLAC TWO EXISTING PANELS AND ONE TRANFRORMER WITH NEW EQUIPMENT AT UNITED AIRLINES PUMP ROOM AT LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70264	14041-10000-17941	14144 W VENTURA BLVD #200	91423	4	165B153   434	2266003092	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			07/02/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.14958	-118.44166	Title 24 plan check only.  Building application submitted 6/20/2014.  Total area = 9,562 sq. ft.Demolition and installation of electrical recepticles and re-distribution of lighting system in existing commercial lowrise (building height = 54').	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70265	11041-10000-09067	11838 W VENTURA BLVD	91604	2	162B169   275	2369027016	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	10/17/2011 12:00:00 AM	ADDRESS	34.14236	-118.39049	EXISTING RESTAURANT.  REMODELING OF ELECTRICAL SYSTEM.  ADDING 2 NEW PANELS, 2 NEW AC UNIT PANELS, 4 NEW EXHAUST SYSTEMS.  FIRE ALARM TO BE SUBMITTED UNDER A DIFFERENT APPLICATION.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70266	15041-10000-27911	222 S MAIN ST	90012	14	130-5A213 144	5161026040	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.05047	-118.2448	Fire alarm installation on a new mixed use building (7 story build.: Retail and Apartment),722 devices with full voice evacuation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70267	12041-10000-07481	17351 W SUNSET BLVD	90272	11	126B117   567	4416003034	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.04039	-118.5542	PROPOSED INTERIOR REMODEL OF  EXISTING RESIDENTIAL BUILDING. CHANGE  FLOOR PLAN CONFIGURATION (CONDO 22,700 SF REMODEL AREA); COMPLY WITH DEPARTMENT ORDER effective date 08/22/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.NO EXTERIOR WORK APPROVED UNDER THIS PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70268	16041-20000-26352	1071 N STRADELLA ROAD	90077	5	144B149   202	4369036019	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.09121	-118.45392	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. 7.6kW ungrounded system.(25) 290W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70269	13041-10000-00499	7756 S ISIS AVE	90045	11	099B173   501	4127018031	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2013 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	33.96598	-118.37553	photovoltaic system for single family dwelling. 1 story unit. microinverter. inverter - enphase m215-60-2ll-s22. solar panel - rec rec 245 pe. pv1 system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70270	15041-10001-42312	9189 N DE GARMO AVE	91352	6	198B173   125	2408034042	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM			PC Approved	01/27/2016 12:00:00 AM	ADDRESS	34.23604	-118.37603	** Supplemental PC to an approved plan, replace old conduits to new conduits from MSB  to DBF & DBE.Permit under 15041-10000-42312*NEW DISTRIBUTION EQUIPMENT FOR EXISTING LOADS AND FUTURE LOADS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70271	19041-10000-32211	2500 W 7TH ST	90057	1	133-5A201 278	5141014001	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.0583	-118.28122	Plan check for a fire alarm system located in a new 3-story building. Scope includes (1) fire alarm panel, (1) communication panel, and (49) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70272	17041-10000-45495	11308 N AMESTOY AVE	91344	12	210B133    95	2697020002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Expired	04/14/2024 12:00:00 AM	ADDRESS	34.27591	-118.50474	ROOF-MOUNTED 8.84KW PV SYSTEM CONSISTING OF 31 EA MODULES/OPTIMIZERS WITH CENTRAL INVERTERSIMPLIFIED PV STD PLAN SUBMITTED	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70273	18041-20000-29500	16644 W DEMARET PL	91344	12	216B137    98	2609010002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	34.29105	-118.49525	permit fees $0.00 by state senate bill #1222pv1install roof mounted pov system sized 10.3 KW AC interconnected with msp.This is an addition to an existing PV system.(45) sunspark modules(45) IQ6 microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70274	13041-20000-10982	230 N LARCHMONT BLVD	90004	4	138B189   530	5515025003	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			04/29/2013 12:00:00 AM			PC Approved	04/29/2013 12:00:00 AM	ADDRESS	34.07557	-118.32343	T24 FOR EXISTING CAFE. 887 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70275	18041-10001-32275	6262 N VAN NUYS BLVD	91401	6	178-5A151 200	2240003907	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.18408	-118.44846	Change to an approved set by adding (1) pre-action panel, and new devices on the plan; all changes under delta-5 only.(((Plan check for a fire alarm system located in a commerical building with (1) fire alarm panel, (12) power supplies, and (363) fire alarm devices.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70276	16041-10002-42999	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	05/17/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	Change to approved by set by modifying the lighting plan, relocate and rotating some conduit run and  equipment on the floor plan. all changes under delta-2 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70277	11041-10001-18773	2005 N HIGHLAND AVE	90068	4	150A185   119	5549030013	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM			PC Approved	12/15/2011 12:00:00 AM	ADDRESS	34.10671	-118.33767	Plan check for revision to approved plans. Delta 2 and 4 revisions. Relocate transformers, switchboard, and panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70278	14041-10000-07702	6290 W SUNSET BLVD UNIT-C	90028	13	147A189   227	5546025029	(Q)C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.09777	-118.32646	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. CHANGE OF USE  OF  EXISTING GO BURGER RESTAURANT TO  NEW STARBUCKS COFFEE SHOP. HIGHRISE 3602 SQFT, EMERGENCY LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70279	10041-10000-08855	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	08/27/2010 12:00:00 AM	ADDRESS	34.06664	-118.46903	NEW LIGHTING FIXTURES AND RECEPTACLES ARE INSTALLED  IN THE BOYS' AND GIRLS' LOCKER ROOMS AT THE GYMN AT BRENTWOOD SCHOOLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70280	18041-10000-42796	13850 W SATICOY ST	91402	6	186B153    38	2214023023	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.21	-118.43498	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70281	19041-10000-16962	13034 W SATICOY ST	91605	2	186B161   442	2303022001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.20697	-118.41695	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70282	18041-20001-13449	7317 N DELCO AVE	91306	3	186B109   908	2114016017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM			PC Approved	04/23/2018 12:00:00 AM	ADDRESS	34.20327	-118.57877	Fees for expedite	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70283	17041-10002-00340	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM			PC Info Complete	02/26/2019 12:00:00 AM	ADDRESS	34.16326	-118.37388	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDITION OF NEW CIRCUITS, REVISION TO LIGHTING PLANS, AND MODIFICATION OF LOAD CALCULATIONS. ALL CHANGES HAVE BEEN NOTED UNDER DELTA 9  Full PC for power and energy. New mixed use housing complex -297 dwelling-unit 6 levels of apartment on top of on grade market (core and shell)  above 2 -level of type I construction parking garage.  Scope includes three new services/distribution boards(2500A & 1600A), new panels, new circuits, and new lights for two structures. Total affected area is 266331 Sq. Ft.  B#16010-10000-04268@@@@BUILDING COVERS TWO ADDRESSES:  5101 LANKERSHIM BLVD AND 5130 KLUMP AVE.@@@	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70284	15041-20000-21840	10906 N CANBY AVE	91326	12	210B125   725	2715003020	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.2684	-118.53475	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (24) micro-inverters, (24) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70285	13041-20000-14318	12580 W SATICOY ST	91605	2	186B161   405	2305025022	M1-1, P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.2075	-118.40783	Plan check for 800A service upgrade and several new panels as well as distribution equipment. No changes within the building(s).  METHANE BUFFER ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70286	15041-10000-41742	20011 W VENTURA BLVD	91367	3	174B113   402	2164001022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Info Complete	12/30/2015 12:00:00 AM	PIN	34.17207471	-118.56880689	TI TO AN EXISTING MEDICAL OFFICE (CHANGE OF USE FROM RETAIL TO MEDICAL.  PLAN CHECK FOR POWER AND ENERGY.  NON OSHPD.BUILDING APPL# 14016-20000-23076Permit under 15041-20000-34106, 15041-10000-38263	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70287	14041-10000-21020	5867 S CENTRAL AVE	90001	9	105B209   588	6007003031	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	10/14/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.98775	-118.25672	Tenant improvement for a fatburger restaraunt.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70288	13041-20000-16954	7831 N KENTLAND AVE	91304	3	189B097   800	2013010026	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2013 12:00:00 AM	06/26/2013 12:00:00 AM		Permit Finaled	12/27/2013 12:00:00 AM	ADDRESS	34.21291	-118.61783	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE: 5.145KW. 21 PANELS AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70289	12041-10000-13807	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM	07/26/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	33.97704	-118.40702	conduit only permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70290	14041-20001-01967	1424 N AVENUE 46	90041	1	156A221   206	5474027026	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			Reviewed by Supervisor	02/07/2014 12:00:00 AM	ADDRESS	34.12152	-118.21634	(expedite fees)PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70291	19041-10000-07870	20929 W VENTURA BLVD UNIT 20	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTS AND EXIT SIGN TO VACANT RETAIL SPACE PLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70292	17041-10000-21689	6399 W WILSHIRE BLVD	90048	5	135B173   818	5510028012	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.06391	-118.36796	PC FOR FA IN 11 STORY HIGH RISE WITH UNDERGORUND LEVEL (MARRIOT HOTEL)TOTAL OF 753 INTIATING AND ANNOUNCIATING DEVICES AND 19 PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70293	17041-10000-24676	3618 S DUNN DR	90034	5	120B165   414	4313008025	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			08/01/2017 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	07/24/2020 12:00:00 AM	ADDRESS	34.02683	-118.4024	plan check for power and energy a 5-story 29-units apartment building over a subterranean garage. Total area is 9,234 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70294	16041-10000-28771	1241 S SOTO ST	90023	14	121-5A221 147	5170017030	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/12/2016 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	10/10/2017 12:00:00 AM	ADDRESS	34.02743	-118.21975	FULL PC FOR POWER AND ENERGY. TI TO AN EXISTING CHARTER SCHOOL. SCOPE INCLUDES NEW NEW DISTRIBUTION BOARDS, NEW TRANSFORMERS, NEW SUBPANELS, AND NEW CIRCUITS. NEW CONNECTED LOAD >400A. TOTAL AFFECTED AREA IS 77316 SQ. FT. B#16014-10000-03851	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70295	17041-10000-22128	20801 W RINALDI ST	91311	12	210B109   548	2706007024	(T)RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1131.01	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	34.27025	-118.58647	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70296	19041-10000-46416	1405 N CABRILLO AVE	90731	15	021B197    77	7445002033	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	33.75648	-118.29602	PV1. NEW ROOFTOP SOLAR SYSTEM CONSISTS OF 22 AC MODULES (SUNPOWER SPR-A400-G-AC)TOTAL SYSTEM SIZE IS 8.80KWdc / 7.68KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70297	18041-20000-12302	20434 W ARBELLA PL	91326	12	216B109   218	2701082032	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.29249	-118.57931	PV1.  PV roof mounted grid tied system.  12.76 kWac with (37) AC Modules connected to load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70298	16041-10000-28409	18759 W WILLOWTREE LANE	91326	12	207B121   531	2728029070	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.26307	-118.5415	Permit fee is $20.73 due to Senate Bill 1222.PV1 SYSTEM FOR SFD WITH 40 MODULES IN TOTAL. USING AC MODULES. CONNECTED TO EXISTING 600A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70299	17041-10000-06277	18120 W SATICOY ST	91335	3	186B125   241	2119006033	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.20824	-118.52809	PC FOR ENERGY. T24 ONLY.  REPLACE EXISTING FIXTURES WITH NEW LED LIGHT FIXTURES, TOTAL AREA  44700 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70300	10041-10000-25767	17641 W VENTURA BLVD	91316	5	171B129   334	2257008026	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	09/29/2011 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.1624	-118.51764	New McDonalds. Plan Check is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70301	14041-20000-29395	13015 W TONOPAH ST	91331	6	195B161   529	2627021027	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.23118	-118.4183	PV1STANDARD PLAN MICROINVERTERS SIZED 3.2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70302	15041-20000-38127	4677 W PICO BLVD	90019	10	129B185   914	5083027014	C4-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.0488	-118.3379	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to an addition to the existing commercial space. Total lighting area = 1,381 sq. ft.Note: Building permit has been pulled under 14014-10000-00412	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70303	10041-20000-13276	4516 W BRAZIL ST	90039	4	165B205    90	5593011003	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	09/13/2011 12:00:00 AM	ADDRESS	34.14673	-118.27306	PLAN CHECK FOR NEW ROOF MOUNTED 120 KW PV SYSTEM FOR COMMECIAL BUILDING WITH MULTIPLE EXISTING SERVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70304	08041-10001-16884	6300 W FOREST LAWN DR	90068	4	165B189    25	5581007***		Central	Hollywood	Hollywood Hills West	YES	9800.09	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM			PC Approved	08/11/2010 12:00:00 AM	ADDRESS	34.1504	-118.32742	Change the priviously approved plan. All changes are shown with cloud. Change CB to Fuses. All changes are shown with cloud. ((((((((((((((TI - Replacement of high voltage switchgear (4800 V), new equipment (High voltage selector switch), new feeds from new swbd.  P/C is for Power only.)))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70305	15041-20000-19272	7621 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.2093	-118.46494	Plan check for PV roof mounted system. System size: 3.6kW with 18 fixtures and 1 inverter(3.6kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70306	14041-20000-10732	18971 W VENTURA BLVD	91356	3	174B121   402	2163020019	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.17265	-118.54698	T.I. to existing building for take out yogurt shop.  Install general lighting.   Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70307	12041-10001-10357	1386 S WESTWOOD BLVD	90024	5	132B153   817	4325016005	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/13/2012 12:00:00 AM			PC Approved	06/13/2012 12:00:00 AM	ADDRESS	34.05556	-118.4417	ALTERATIONS TO AN EXISTING RESTAURANT WITH NO CHANGES IN THE EXISTING SECTION OF THE RESTAURANT; PER ELEC INSPECTOR, TITLE 24 PLAN IS REQUIRED.PERMIT WAS OBTAINED ON 12041-9000-10357Remodeling -add 12 new circuits to existing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70308	12041-10000-07180	275 W CENTER WAY	90045	11	090B165   113	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM			Reviewed by Supervisor	10/23/2012 12:00:00 AM	ADDRESS	33.94386	-118.4047	Plan check power and energy for new LAX CTA Central Utility Plant - Thernal Energy Storage (TES) Tank	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70309	16041-20000-39707	1205 E 6TH ST	90021	14	126A215   332	5164009012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			11/17/2016 12:00:00 AM	11/30/2016 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.03828	-118.23807	PV2.  Install 4.80 kW DC roof mounted grid-tied PV system.  (15) modules with (1) 10.0 kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70310	14041-20000-11523	10476 N VANALDEN AVE	91326	12	207B121   706	2728015002	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	06/03/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.26144	-118.54922	pv1 single family dwelling. total system size 10kw ac using transformerless ivnerter. nonstandard plan. using power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70311	18041-10000-12440	5500 W JEFFERSON BLVD	90016	10	120B173   315	5047015011	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.02557	-118.3665	PLANCHECK FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT TO EXISTING 2-STORY OFFICE BUILDING. 72,000SQFTBUILDING PERMIT # 18016-10000-06520	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70312	19041-20000-26961	3502 S TROUSDALE PKWY SOS-B49	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	08/23/2019 12:00:00 AM	ADDRESS	34.02175	-118.28408	TI TO AN EXISTING COMMERCIAL SPACE(CLASSROOM).  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR INDOOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70313	09041-10001-24260	10106 W EMPYREAN WAY	90067	5	129B161    12	4329006***	R4-1L-O, R4-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM			PC Approved	10/08/2010 12:00:00 AM	ADDRESS	34.05377	-118.40899	"Revision to P/check approved under PCIS 09041-20000-20652 ; to an existing 1200a UGPS, connect to either side A 600 DISCONNECT AND 2 EA 3-METERS SECTIONS. THROUGH A 4"" CONDUIT NIPPLE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70314	19041-10000-05757	414 S NEW HAMPSHIRE AVE	90020	10	135B197   536	5502009002	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2119.21	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.06692	-118.29275	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70315	17041-20000-19461	1604 S PACIFIC AVE	90291	11	106-5A145   4	4238014009	C2-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	33.98767	-118.47174	TI to (E) restaurant space.  Plan check for energy.  849 sq ft.  Electrical permit previously issued under 17041-90000-17925	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70316	13041-10000-23403	10821 N MELVIN AVE	91326	12	207B117    82	2708011001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2013 12:00:00 AM	08/27/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.26698	-118.56034	PV1 5.88KWdc 240V XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [( 1) INV: PVI-6000-OUTD-US] [( 18) MOD: SUNPOWER spr-327ne-WHT-D]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70317	16041-10000-06165	4121 W SANTA MONICA BLVD	90029	13	145-5A201 383	5429002026	C2-1D	Central	Hollywood	Silver Lake		1913.01	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.09205	-118.28241	A new one story core and shell retail and parking garage, 2500 amp servicce. Total sq. ft. 37,585	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70318	10041-10000-15653	10351 W SANTA MONICA BLVD	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			08/11/2010 12:00:00 AM			PC Approved	08/11/2010 12:00:00 AM	PIN	34.0585564	-118.42324002	TI IN AN EXISTING LOBBY AREA OF AN OFFICE BUILDING. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70319	19041-20000-13676	700 S FLOWER ST 1100	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM			PC Info Complete	04/15/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	T24 PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL OFFICE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 10,135 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70320	13041-20000-14274	8525 W PICO BLVD	90035	5	132B173  1243	4332028039	C4-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.0537	-118.377	Change of use from Office to Medical Dental Office.  Full Plan CHeck.  Not a state licensed building, Not Checked for OSHPD3.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70321	14041-20000-35874	5234 N LEMP AVE	91601	2	171B169   310	2348006063	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.16589	-118.38434	PV1. Install roof mounted system sized 4.3 kW. Interconnected with main service pannel.(18) Sunmodule Plus SW 275 mono modules(18) Enphase M250 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70322	18041-10002-03812	14626 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			08/28/2018 12:00:00 AM			PC Approved	08/28/2018 12:00:00 AM	ADDRESS	34.22128	-118.45073	THIS IS PLAN CHECK ONLY!DELTA 3 CHANGES TO APPROVED PLANS. REVISED LIGHTING AT ENTRY WITH DIFFERENT FIXTURE AND READJUSTING OF PREVIOUSLY APPROVED FIXTURE IN THE GENERAL SPACE. SOME CHANGES TO CIRCUITING IN THE BOH. T-24 ENERGY ONLY. PLAN CHECK ONLY. PERMIT# 18041-10000-03812<<<<<<<<FULL PC FOR POWER AND ENERGY FOR A NEW SHELL BUILDING. SCOPE INCLUDES A NEW 1200A 120/208V 3 PHASE 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 23014 SQ. FT. B#18010-10000-00386>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70323	12041-20000-18608	6114 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.00, 1909.02	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	08/08/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.09785	-118.32294	T.I. to existing building, suite 6114B.  Install general/emergency lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70324	18041-10001-10037	9034 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM			PC Approved	10/19/2018 12:00:00 AM	ADDRESS	34.23415	-118.55337	10-19-2018 Changes to an approved set of plan. Changes include remove fire alarm devices and Fire alarm panel from scope of work. All Changes has been clouded as delta 7. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70325	19041-10000-53868	5811 N OAKDALE AVE	91367	3	174B113   113	2153016031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Issued	12/31/2019 12:00:00 AM	ADDRESS	34.17614	-118.56582	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10KWac AND 10.34KWac CEC, SYSTEM INCLUDES 36 MODULES (HANWHA Q-315) WITH OPTIMZERS (SEP400) AND A CENTRAL INVERTER (SE10000H-US). NO MPU	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70326	17041-10000-02877	7652 N TEXHOMA AVE	91325	12	186B129    67	2202003008	RA-1, RA-1-K	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.21006	-118.51523	"PV1. NEW SOLAR SYSTEM ON EXISITNG RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(34)MODULES-PANASONIC VBHN325SA16(34)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SE10000A-USNote: Permit for PV system for meter ""B"" is under PCIS#17041-10000-02873"	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70327	16041-10000-02078	14758 W FRIAR ST	91411	6	178-5A149  26	2241007012	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	34.18552	-118.45505	PV1 ROOF MOUNTED MICROINVERTERS. 19 MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70328	15041-10000-22123	957 S WINDSOR BLVD	90019	4	132B189   925	5090024023	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	07/23/2015 12:00:00 AM	ADDRESS	34.05586	-118.32539	PV 1 ROOF MOUNTED 7.02 KW PV SYSTEM. (27) MODULES KYOCERA #KU2606XPA(1) INVERTER ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70329	18041-10000-21809	1516 N SAN PABLO ST	90033	14	135A225    64	5202004042	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	01/15/2019 12:00:00 AM		Issued	01/15/2019 12:00:00 AM	ADDRESS	34.06268	-118.20282	PC FOR ENERGY ONLY, PROJECT CONSISTS OF REMODEL OF THREE(E)ROOMS AT LEVEL 4. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL SQ. FT. 946.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70330	13041-10000-01274	1055 W 7TH ST 3250	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			Corrections Issued	01/29/2013 12:00:00 AM	ADDRESS	34.0507	-118.26334	TI for office. Adding lighting and receptacles. Fixtures are not changing location [1 to 1]. The wiring is not changing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70331	16041-20001-12351	309 E 8TH ST STE 202	90014	14	126A211    30	5145003009	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM			PC Approved	04/14/2016 12:00:00 AM	ADDRESS	34.04121	-118.25128	4.14.2016 - Plan check for modifications to approved set. Occupant sensor layout in open office changed. Light fixture F1 now has an integrated occupancy sensor. Update T-24 controls form to reflect new O.S. count.Changes to circuiting/power plan (not covered under T-24 only plan check).====Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,336 sq. ft.Note: Building permit has been pulled under 16016-10000-02985	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70332	12041-20000-18590	2445 N DALY ST	90031	1	139-5A221 259	5204004803	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			08/08/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.07502	-118.21584	Plan check for power. Relocation of a 1600A tap box. AT&T. Not a methane hazard site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70333	18041-20000-20669	7057 N VASSAR AVE	91303	3	183B101   236	2138002027	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			06/04/2018 12:00:00 AM			PC Info Complete	02/28/2019 12:00:00 AM	ADDRESS	34.19892	-118.60463	Plan check for power and energy, service size: 1200A 120/208V 3 Phase 4W. Total area: 20,811 sq ft.B#18010-10000-01363Fire alarm Modification has been filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70334	16041-20003-08117	3664 N WILLOW CREST AVE	91604	2	159B173    37	2380006006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM			PC Approved	08/09/2016 12:00:00 AM	ADDRESS	34.13615	-118.36756	08/09/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes include the replacement of the MSP with a solar-ready panel.[[6/14/16 CHANGES TO APPROVED SET.  ADDITION OF 5 MODULES AND UPGRADING INVERTER TO SE7600]]]$0 permit fee due to State Senate Bill SB-1222. Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (2) inverters, (56) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70335	12041-10000-10914	2729 N NORTH MAIN ST	90031	1	136-5A223 405	5210009026	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			05/11/2012 12:00:00 AM	05/11/2012 12:00:00 AM		Permit Finaled	12/20/2012 12:00:00 AM	ADDRESS	34.0662	-118.21317	TI IN AN EXISTING COMMERCIAL SPACE.  (NON HAZARDOUS GENERAL AREA)  PLAN CHECK FOR T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70336	19041-10000-47531	8501 S SAN PEDRO ST	90003	9	097-5A205 259	6030018013	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Issued	11/19/2019 12:00:00 AM	ADDRESS	33.96083	-118.26971	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70337	17041-10000-43214	1375 E 6TH ST Bldg B	90021	14	126A217    90	5164008021	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.03838	-118.23365	REPLACE EXISTING FIXTURES WITH LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED ARE AIS 20150 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70338	10041-20002-10030	333 S ALAMEDA ST	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM			PC Approved	07/29/2011 12:00:00 AM	ADDRESS	34.04448	-118.23824	Revision to approved plan. Replace lights with trk lights & addition of a lighting control panel. (((((((((((((Change of use from game shop to the restaurant. Plan check for power and energy.)))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70339	17041-10000-28276	10531 W BLOOMFIELD ST	91602	4	165B177   424	2424011014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.14972	-118.36032	NEW ROOFTOP SOLAR INSTALLATION. 22 MODULES (1) INVERTER  7.6 KW AC SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70340	17041-10000-24588	2080 E CENTURY BLVD 101-304	90002	15	091-5A215 217	6046019917	OS(UV), RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	12/17/2020 12:00:00 AM	ADDRESS	33.94629	-118.23501	New 3-story, 20-unit apartment building. 800 A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70341	17041-10000-31986	9081 N TUJUNGA AVE	91352	6	198B169    68	2538009008	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	05/04/2018 12:00:00 AM	ADDRESS	34.23342	-118.3809	T-24 ONLY, PC FOR NEW OUTDOOR LIGHTS IN WASTE MANAGMENT ENTRANCE FACILITY. TOTAL AFFECTED AREA 74,000 B#17010-10000-01571 (FOR NEW SCALE HOUSE ONLY)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70342	14041-20000-35758	4829 N FULTON AVE Bld. 6F	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	05/21/2021 12:00:00 AM	ADDRESS	34.15876	-118.42353	New 3 story building with 21 units.  New 800A service, panels, and branch circuits.  Plan check for power only.Note: Variance to separate fire alarm submitted on 12/29/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70343	17041-20002-31574	8800 N CHIMINEAS AVE	91325	12	195B125   688	2769016013	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM			PC Approved	09/22/2017 12:00:00 AM	ADDRESS	34.23023	-118.52829	9.22.2017 - Plan check for modifications to approved set. Add disconnect ahead of ESS on outside wall. Change clouded - only change.======PV1.  Install 4.13 kW roof mounted grid tied PV system.  (14) modules with 3.0 kW rated central inverter.   13.5 kWh energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70344	15041-20000-38547	14345 W NORDHOFF ST	91402	6	198B153   901	2639010001	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.23554	-118.44501	Plan check for PV roof mounted system. System size: 18.5kw with 71 modules(Kyocera) and 2 inverters(7.6kW and 8.2kW) connectted to load center.note: permit fees are $0 due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70345	16041-10000-42964	5533 W VIRGINIA AVE	90038	13	144B193   513	5536008015	R4-1VL	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM	02/14/2022 12:00:00 AM		Issued	02/14/2022 12:00:00 AM	ADDRESS	34.0919	-118.31033	FULL PLAN CHECK FOR POWER AND ENERGY. NEW CONSTRUCTION OF A 4 STORY 15 UNITS APARTMENT BUILDING. TOTAL SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70346	15041-20000-22836	914 S OLIVE ST	90015	14	127-5A209 166	5139004017	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Issued	01/29/2016 12:00:00 AM	ADDRESS	34.04319	-118.25843	Plan check for power and lighting. Project site is an existing 2-story commercial building. Project scope is the installation of a new 600-amp service, distribuition board, and associated loads. panelboards a b and ac are exisiting. Total lighting area = 3,720 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70347	17041-10000-00997	5315 1/2 S BROADWAY	90037	9	108B201   476	5101035003	C2-1VL	South Los Angeles	Southeast Los Angeles			2328.00	Electrical	Electrical	Commercial			01/11/2017 12:00:00 AM			PC Approved	01/11/2017 12:00:00 AM	ADDRESS	33.99386	-118.2785	T-24, TO AN (E) COMMERCIAL SPACE, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. INSPECTION FEES HAVE BEEN PAID UNDER APP# 16041-70000-18290.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70348	11041-20000-01132	1700 E 4TH ST 1-12	90033	14	127-5A219 318	5171023001	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Public Safety Only			01/20/2011 12:00:00 AM	01/20/2011 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	ADDRESS	34.04273	-118.22151	Plan check for new fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70349	16041-10000-30488	1650 S TARLETON ST	90021	14	120A213   310	5129010009	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	01/09/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.02201	-118.24455	PC FOR POWER. UPGRADE SERVICE FROM 200A TO 8OOA. ADDITON OF 4 NEW PANELS, FULLY CONNECTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70350	13041-10000-05366	1930 S CENTURY PARK WEST	90025	5	132B157   646	4319003063	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	PIN	34.05705589	-118.41909499	PLAN CHECK AND PERMIT FOR NEW METHANE DETECTION SYSTEM FOR WESTFIELD PARKING STRUCTURE. METHANE ZONE LEVEL I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70351	15041-10000-26817	7640 N GLORIA AVE STE F	91406	6	186B141    28	2206010020	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.20953	-118.47917	REMOVE AND REPLACE EXISTING LIGHTS TO LED LIGHT FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTALL SQUARE FOOTAGE 4864.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70352	14041-10000-03509	709 N ALFRED ST	90069	5	141B173   381	5528001053	[Q]R3-1	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			02/07/2014 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	PIN	34.08411322	-118.37559482	Plan check for power. 800 amp service with 6 new subpanel. All branch circuits are existing. Six new sub panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70353	16041-20000-24821	12710 N GOETHE PL	91344	12	222B133   668	2608003011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.30137	-118.51067	Install a roof-mounted solar array on a SFD. Interconnect with a 125A MSP. Derating main to 100A.7.6kW Ungrounded system. (28) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70354	12041-10000-20360	8943 N COLLETT AVE	91343	12	195B141   196	2672002006	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2012 12:00:00 AM	09/24/2012 12:00:00 AM		Permit Finaled	10/10/2012 12:00:00 AM	ADDRESS	34.23324	-118.48413	Plan check for 11.52KW roof mounted photovoltaic system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70355	18041-10000-37159	1875 S CENTURY PARK EAST UNIT 1860	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Issued	10/17/2018 12:00:00 AM	ADDRESS	34.06115	-118.41457	INTERIOR OFFICE TI ON THE 20th Floor. T-24 ENERGY ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70356	14041-20001-31042	4260 N EAGLE ROCK BLVD 1-56	90041	1	156A219   115	5474022023	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Eagle Rock		1862.01	Electrical	Electrical	Apartment			11/07/2014 12:00:00 AM			PC Approved	12/05/2014 12:00:00 AM	ADDRESS	34.12246	-118.22336	EXPEDITE PER APPLICANT REQUEST[PV2Install a roof-mounted solar array on an Apartment building. Interconnect at 600A Main Panel.System size: 14.4kW. Ungrounded system.(60) EnPhase M250 microinverters with (60) 300W pv modules across 4 strings (15+15+15+15).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70357	18041-20001-23643	7215 W WARING AVE	90046	5	141B181   259	5525002038	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM			PC Approved	08/23/2018 12:00:00 AM	ADDRESS	34.08537	-118.34667	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 34.12 kWdc/33.184 kWac-CEC and consists of (2) 14.4 kWac rated inverters, (105) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70358	14041-10000-30951	2700 W COLORADO BLVD	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	06/03/2015 12:00:00 AM		Issued	06/03/2015 12:00:00 AM	ADDRESS	34.14248	-118.22438	T-24 plan check 1,712 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70359	12041-10000-10145	17252 W DEARBORN ST	91325	12	198B133   536	2692006006	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2012 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.23693	-118.51058	New 7.2kw photovoltaic rooftop system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70360	12041-20000-12780	1181 N VIRGIL AVE	90029	13	145-5A201 239	5542026022	R2-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	Apartment			06/04/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	01/14/2015 12:00:00 AM	ADDRESS	34.09322	-118.28673	Enphase photovoltaic system on the roof of apartment buildings.  Building A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70361	13041-10000-23536	3620 S MCCLINTOCK AVE	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.0213	-118.28935	Seeley g. mudd building 1st and 2nd floor labs renovation.PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70362	18041-20000-28190	633 W 5TH ST 5100	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	ti to an existing high rise building.  adding new lighting new controls to existing panels.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70363	11041-20000-24010	7250 W FRANKLIN AVE 1-193	90046	4	147B181    21	5548025***	R3-1	Central	Hollywood	Hollywood Hills West		1899.03	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM			PC Approved	11/09/2011 12:00:00 AM	ADDRESS	34.10329	-118.34724	T.I.  New outdoor lighting for the Franklin Towers.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70364	19041-10001-18417	930 S HILGARD AVE Level-2	90024	5	135B153   541	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.06306	-118.44116	PLAN CHECK ONLY. T-24 CHANGES TO AN APPROVED SET TO INCLUDE LOWER FIXTURE WATTAGE (LF-18), ADDITION OF 1 96W POWER SUPPLY  AND REDUCE THE COUNT OF FIXTURE LF-3. SCOPE ALSO INCLUDE NEW 9KVA TRANSFORMER AND PANEL FOR AUDIO AND VISUAL CIRCUITS. ALL CHANGES ARE MARKED BY DELTA 1PERMIT FEES ARE UPDATED AND PAID UNDER MASTER APPLICATION Energy plan check for the 2nd floor of a hotel T.I. Scope includes new lighting and equipment with a total lighting area of 6692-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70365	14041-20001-21545	11374 N FERRARA LANE	91326	12	213B109    70	2701049030	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2014 12:00:00 AM			Reviewed by Supervisor	08/22/2014 12:00:00 AM	ADDRESS	34.27819	-118.58063	expedite feespv1 sfd. total system size 7.8kw AC using 2 transformerless inverters. nonstandard plan. derrating main breaker. total of 37 modules. connect to center fed bus	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70366	19041-10000-37751	4760 W SUNSET BLVD 1st Flr	90027	13	147B197   733	5543015021	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.09788	-118.29343	ENERGY PLAN CHECK FOR THE FIRST FLOOR OFFICE T.I LOCATED IN A MEDICAL OFFICE BUILDING. SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH NEW WALLS AND (3) NEW OFFICES  REMODELING. EXAM ROOM IS NOT PART OF THE SCOPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70367	17041-10001-02862	9163 N KEWEN AVE	91352	6	198B165   343	2629014075	RS-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2017 12:00:00 AM			PC Approved	03/09/2017 12:00:00 AM	ADDRESS	34.2358	-118.39935	FEE FOR OFF-HOUR PLAN CHECK FOR APPLICATION 17041-10000-02862PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM FOR SINGLE FAMILY DWILLINGSYSTEM SIZE = 7.6KVA, USING 2 INERTERS(ABB-3.8-OUTD--S-US) WITH 27 MODULES (SUNPOWER-SPR327NE-WHT-D).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70368	14041-10000-06160	5636 N TUJUNGA AVE	91601	2	174B173   775	2337039019	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	05/29/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.1733	-118.37885	TI FOR CREDIT UNION SPACE. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70369	10041-10001-19255	801 N FAIRFAX AVE	90046	5	141B177   249	5529021070	(T)(Q)RAS4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			10/12/2010 12:00:00 AM			PC Approved	10/12/2010 12:00:00 AM	ADDRESS	34.08567	-118.36172	TI IN EXISTING COMMERCIAL SPACE; PERMIT HAS BEEN OBTAINED;PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70370	15041-20000-09064	865 S FIGUEROA ST 18th Floor	90017	14	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.04653	-118.26275	Plan check for a Title 24 only. Project scope is a tenant improvement to a video conferencing room on the 18th floor of a high-rise building. Total lighting area = 1,282 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70371	19041-10001-14680	189 S THE GROVE DR #J1A	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	11/14/2019 12:00:00 AM	ADDRESS	34.07125	-118.35662	Change to an approved set which includes adding lighting fixtures and changing location of equipment to reflect existing conditions. All changes are marked under delta 3 through 5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70372	16041-10002-12348	505 S VIRGIL AVE #305	90020	13	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.0649	-118.28724	Full plan check for first time tenant.  ENERGY PLANCHECK CONDUCTED AND PERMIT WAS ISSUED. THIS APPLICATION IS PLANCHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70373	16041-10000-42206	838 W 30TH ST	90731	15	009B197  1349	7469010009	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2975.00	Electrical	Electrical	Commercial			12/01/2016 12:00:00 AM	01/13/2017 12:00:00 AM		Permit Finaled	04/03/2017 12:00:00 AM	ADDRESS	33.71751	-118.29665	PV2 roof mounted solar system installation to a commercial site. Intalling a 3.0 kw central inverter with 18 solar modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70374	15041-10000-28956	409 N HAYWORTH AVE	90048	5	138B177    35	5527032028	R3-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.0785	-118.36277	PC at counter for a new fire alarm system to a commercial apartment units (33 units). scope of work: (142) FA devices, (4) power supplies, (1) FA panel, (1) communication panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70375	12041-20000-08188	16521 W SATICOY ST	91406	6	186B137    22	2205009009	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	ADDRESS	34.20858	-118.49305	Changes to approved plan. Plan check for power and energy. Single story commercial building. 3,730 conditioned sqft, 6121 unconditioned sqft, 5460 outdoor sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70376	14041-10000-07138	8022 W 3RD ST	90048	5	138B177   761	5511028021	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	09/05/2014 12:00:00 AM	ADDRESS	34.07182	-118.36461	TI to Existing Restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70377	15041-10000-39194	3640 W WILSHIRE BLVD 1-209	90010	10	132B193    62	5093019018	(T)(Q)C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	34.06145	-118.30446	NEW FIRE WARNING SYSTEM FOR  7 STORIES 209 APT UNITS BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70378	18041-20000-04345	6701 S CENTER DR WEST suite 480	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	33.97907	-118.39369	ti to an existing commercial building high rise).  adding new lighting new controls to existing panels.  plan check for energy indoor only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70379	16041-20000-13739	10216 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.25596	-118.57964	Plan check for power only. Project site is an existing commercial building. Project scope is a 800-Amp service upgrade and replacement of tenant panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70380	14041-10000-33492	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	Plan check per applicant request : Power plan check for a New 400-Amp electrical service for domestic water pumps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70381	13041-20000-23968	6320 N CANOGA AVE 630E/640E	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.18499	-118.59722	Split one suite into two in an existing high-rise office building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70382	17041-20000-42226	10410 N BECKFORD AVE	91326	12	204B121    44	2728010002	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.25935	-118.55103	pv1install roof mounted pv system sized 5kw interonnected with msp.  line side tap.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70383	16041-20000-30173	5600 W WASHINGTON BLVD	90016	10	123B177   288	5063022035	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	10/17/2016 12:00:00 AM	ADDRESS	34.03607	-118.36582	Plan check for energy only. New bathroom in existing warehouse. New light. 64sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70384	17041-10000-43538	7151 W MANCHESTER AVE	90045	11	096B161   668	4113013028	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM			Corrections Issued	12/04/2017 12:00:00 AM	ADDRESS	33.95996	-118.41843	T-24, SCOPE OF WORK INCLUDES RETROFITTING OF EXISITNG LIGHTING, ONLY. TOTAL SQ. FT. 5000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70385	18041-10000-18064	846 N SIERRA BONITA AVE	90046	5	141B177    39	5526003016	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.08667	-118.35415	INSTALL A NEW FIRE ALARM SYSTEM WITH 62 DEVICES AND TWO PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70386	17041-10004-12213	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	34.01173	-118.28296	SUPP. PC FOR REVISIONS TO APPROVED SET. ALL CHANGES MARKED UNDER BULLETIN 11 (THROUGHOUT THE ENTIRE PROJECT) UNDER DELTA 8. SCOPE INCLUDES REVISIONS TO LIGHTING INCLUDING T-24 FORMS REVISIONS,  ADDITION AND REMOVAL OF CIRCUITRY INCLUDING REVISIONS TO PANEL SCHEDULES TO REFLECT CORRECT LOADING.  THIS IS PLAN CHECK ONLY. ALL PERMIT ELEMENTS UNDER BULLETIN 12 DELTA 9.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70387	13041-10000-01196	18333 W GAULT ST	91335	3	183B125   364	2125003800	M1-1	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.19941	-118.53265	PARKING LOT CANOPY - 2 LIGHTING FIXTURES INSTALLED.  SMALL T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70388	13041-10000-13504	8938 N HANNA AVE	91304	12	195B101    70	2010021028	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2013 12:00:00 AM	07/17/2013 12:00:00 AM		Permit Finaled	09/18/2013 12:00:00 AM	ADDRESS	34.233	-118.60653	PV1.  Install 9.81 kW DC roof-mounted solar array and interconnect into existing main service panel.  {38 modules: SunPower E20/327} {2 transformerless inverters: PVI-5000-OUTD-US}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70389	19041-20000-13092	1326 S MARIPOSA AVE 1-15	90006	1	129B197  1224	5075008010	R3-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Apartment			04/10/2019 12:00:00 AM			Reviewed by Supervisor	05/09/2019 12:00:00 AM	ADDRESS	34.04641	-118.29852	PLAN CHECK FOR NEW 5 STORY 15 UNIT APARTMENT BUILDING. NEW 600A SERVICE, 600A PANEL, A 150A HOUSE PANEL FED BY A 150A PANEL, A 15HP ELEVATOR MOTOR,  AND (15) 100A SUB PANELS FOR UNITS, 2 TYPICAL UNIT TYPES, T24 INCLUDED, TOTAL SQUARE FOOTAGE = 5,820SFbuilding permit under 19010-20000-00471	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70390	12041-10001-05678	1355 S FLOWER ST	90015	14	126A205   115	5134010019	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Apartment			02/13/2013 12:00:00 AM			PC Approved	04/11/2013 12:00:00 AM	ADDRESS	34.03876	-118.268	Revisions to permitted set of plans for valued engineering (FY)NEW 7-STORY, 80 DWELLING UNITS (76 APARTMENTS AND 4 LIFE/WORK UNITS) COMPLEX WITH SUBTERRANEAN PARKING.PLAN CHECK POWER AND ENERGY. IN METHANE ZONE.VARIANCE TO SEPARATE THE FA PLANS WAS OBTAINED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70391	18041-10001-48699	7560 WORLD WAY	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM			Reviewed by Supervisor	09/24/2019 12:00:00 AM	ADDRESS	33.94055	-118.42896	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF CIRCUITS, LIGHTING AND T-24 FORMS. NOTE CHANGES ON CLOUDED AREA DELTA 1. ___________________________________________________________PLAN CHECK FOR POWER AND ENERGY FOR BRAND NEW STORAGE BLDG @ LAX/DELTA HANGAR. NEW 1600A DISTRIBUTION CENTER WITH ASSOCIATED EQIPMENT CONNECTRED TO EXISTING 3000A 480/277V SERVICE. TOTAL AFFECTED AREA = 20692 SF.MISSING PANELS LPC2 AND LMPC2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70392	19041-10000-32502	1157 W 14TH ST	90731	15	012B193   200	7458022012	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	33.73144	-118.30247	[EPLAN] PLAN CHECK FOR NEW ESS(TESLA POWERWALL) CONNECTED TO AN EXISTING PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70393	17041-10000-13756	940 S FIGUEROA ST	90015	14	127-5A207  15	5138002019	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/26/2017 12:00:00 AM			PC Info Complete	05/04/2017 12:00:00 AM	ADDRESS	34.04538	-118.26335	Title 24 plan check.  T.I. on 4th floor of existing commercial low rise building.  Remodel commercial kitchen and install 4 roof mounted HVAC units.  3 new subpanels.  Total new load is less than 400 amps.  Total area = 1,519 sq. ft.     Building permit #17016-10000-07638	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70394	11041-10000-09564	5771 W 96TH ST	90045	11	093B169   134	4125021010	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			05/11/2011 12:00:00 AM			PC Approved	05/11/2011 12:00:00 AM	ADDRESS	33.94955	-118.38342	EXISTING OFFICE SPACE.  INSTALLING NEW LIGHTING FIXTURES.  ENCLOSING EXISTING WALKWAY.  TITLE 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70395	14041-20003-35051	3433 E ALICE ST	90065	1	147A219   237	5454027002	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.10	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2015 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	34.09659	-118.2259	Fee is 0.00 due to senate bill 1222.Change to approved set by relocating some PV module on the roof plan. (((PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZE 7.6 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL.(22) SUNPOWER E20/327MODULES(2) POWER ONE PVI3.8 INVERTERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70396	12041-20001-06073	4459 W SUNSET BLVD CAFFE VITA	90027	4	147A201   112	5542009014	C2-1D	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			04/18/2012 12:00:00 AM			PC Approved	04/18/2012 12:00:00 AM	ADDRESS	34.09799	-118.28651	energy plan check  for revised fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70397	18041-20000-25116	15540 W RINALDI ST	91344	12	213B145    92	2662001030	C4-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.27881	-118.47085	ti to an existing commercial building. adding new indoor lightig only.  plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70398	19041-20000-00755	3113 S LA CIENEGA BLVD	90016	10	123B173  1681	4205035014	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.02998	-118.37407	T-24 FOR A TI IN A COMMERCIAL OFFICE SPACE. SCOPE INCLUDES NEW CIRCUITS, RECEPTACLE AND LIGHTING. TOTAL AFFECTED AREA IS 257 SQ.FT. PLAN CHECK ONLY. ELECTRICAL PERMIT FEES COVERED UNDER#19041-90000-01116	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70399	13041-20000-13040	8945 N QUARTZ AVE	91324	12	195B113    26	2782038007	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.01	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	05/20/2013 12:00:00 AM	ADDRESS	34.23301	-118.56488	Plan check for energy only. warehouse (no emergency lighting).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70400	12041-10000-19053	2050 W JOHN S GIBSON BLVD	90731	15	024B201     7	7440016912	[Q]M3-1	Harbor	Port of Los Angeles	Northwest San Pedro, Wilmington		2951.01	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/29/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	33.75959	-118.28627	New Fire Alarm System at the Port of LA Berth 121.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70401	13041-10000-07174	530 W 6TH ST FLOOR 12	90014	9	129A209    78	5144004012	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.04853	-118.25518	T24 for a 12th floor elevator lobby renovation in a 14-story building.  1545 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70402	13041-10001-30867	12253 W HART ST	91605	2	183B165   255	2321002037	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.19769	-118.40036	Expedited RSES plan check per applicant request.(((PV1, Install 3.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70403	16041-20000-24401	6341 W NANCY ST	90045	11	102B165   189	4110012014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	33.97691	-118.39765	PV1INSTALL ROOF MOUNTYED PV SYSTEM SIZED 5KW, STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70404	14041-10000-07253	12521 N NEDRA DR	91344	12	219B133   320	2609022027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	06/06/2014 12:00:00 AM	ADDRESS	34.2978	-118.49962	Senate bill 1222 solar fee cap has been reached - fee should be $0.00PV1 20.25KWdc. 240V. microinverter. NONstd. ???story. Roofmount. [(81) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(81)modules: {solarworld SunModule SW-250 mono }]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70405	14041-10001-15184	3018 W ANGUS ST	90039	4	150A205    98	5432012004	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM			PC Approved	06/24/2014 12:00:00 AM	ADDRESS	34.10637	-118.27056	EXPEDITED PER APPLICANTS REQUESTPV1. ROOF MOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 6.21 DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70406	16041-10000-14336	12950 N BORDEN AVE	91342	7	222B153   923	2509006087	(T)R1-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	PIN	34.30542687	-118.44011566	PV1, INSTALL 3.08 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(1) INVERTER: FRONIUS GALVO 3.1-1(11) SOLARWORLD SW280 MONO	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70407	11041-10000-00574	1999 S AVENUE OF THE STARS # 1260	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/12/2011 12:00:00 AM		Permit Finaled	02/01/2011 12:00:00 AM	ADDRESS	34.05886	-118.41642	adding and relocating luminaires in office spacesplan chk is for title 24 and 1 ea emergecy ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70408	17041-10000-45707	18050 W VANOWEN ST	91335	3	180B125    48	2122028013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.19372	-118.52686	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70409	14041-10001-01585	3941 S MARCASEL AVE	90066	11	111B157    77	4214021014	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.00415	-118.42563	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 6 kW DC roof-mounted solar array for a one story house, interconnect with exsisting service panel. (1) Inverter(s): POWER-ONE AURORA PVI-6000-OUTD-US.(24) Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70410	15041-20000-01982	17910 W STRATHERN ST	91335	12	189B129   464	2101028013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	34.21555	-118.52331	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system.26 250W pv modules across 2 strings (13+13).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70411	16041-10001-28142	1550 N EL CENTRO AVE	90028	13	148-5A189 308	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Issued	08/17/2016 12:00:00 AM	ADDRESS	34.09961	-118.32359	TI-24 for new restaurant in existing high rise total area 2431 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70412	16041-10000-43610	5533 S EA WAY	90094	11	102B157   357	4211022***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.97374	-118.42896	METHEANE GAS  DETECTION SYSTEM FOR PLAYA VISTA PHASE ONE, DESIGN LEVEL 2. 33 FA CONTROL DEVICES AND ONE FA CONTROL PNEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70413	12041-20000-23663	4661 W WILSHIRE BLVD	90010	4	135B185   569	5505007017	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			10/03/2012 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	34.06213	-118.33079	CONSTRUCTION OF A NEW THREE-STORY, 12 UNIT APARTMENT BUILDING WITH ONE LEVEL OF BELOW GRADE PARKING  <<<<SITE IS IN A METHANE ZONE>>>>>  ((See apllication #12010-10000-01777 for Methane System Details))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70414	19041-20000-29904	326 N BONHILL ROAD	90049	11	135B141   655	4403016009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	12/17/2019 12:00:00 AM	ADDRESS	34.0644	-118.48186	Install 27 kWh energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70415	14041-10000-17248	1919 S SEPULVEDA BLVD	90025	5	126B153   266	4323025039	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.04399	-118.44146	T.I. - PARTIAL REMODEL OF (E) RETAIL SPACE PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70416	16041-10000-23218	825 W ADAMS BLVD	90007	1	123A201   160	5124024009	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Apartment			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.03043	-118.28059	PC FOR A NEW FIRE ALARM SYSTEM FOR EXISTING APARTMENT BUILDING (3 STORIES). SCOPE INCLUDES:56FA DEVICES 1 COMM PANEL 1 FIRE ALARM PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70417	15041-20000-25311	20748 W EXHIBIT PL	91367	3	177B109    93	2149012031	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.17867	-118.58528	Installation of new roof mounted solar PV array.  Total system size = 8.2 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70418	18041-10000-15487	2230 N PASADENA AVE	90031	1	139-5A221 230	5204002900	PF-1-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.07549	-118.21785	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70419	17041-20000-31138	9448 N TOPANGA CANYON BLVD	91311	12	198B101    79	2746013020	[Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	09/06/2018 12:00:00 AM	ADDRESS	34.24211	-118.60602	Plan check for power and energy. Phase 1 of change of use from office/warehouse to hydroponic agricultural enterprise/office. Project scope limited to Warehouse #s 1-5 and Lab. New lighting (incl. emergency) - 19,123sqft. New distribution > 400A of load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70420	16041-10000-09286	10600 N WHEATLAND AVE	91040	7	207B177   136	2528031001	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Expired	04/24/2018 12:00:00 AM	ADDRESS	34.26266	-118.35832	PV1, rooftop solar installation 7kW system    (36) KD215GX     (1) SMA SB7000US   Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70421	15041-20000-07573	6250 N TOPANGA CANYON BLVD F-1570	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM			PC Info Complete	06/18/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	Plan check for power and energy.  Total area = 2,953 sq. ft.T.I. to retail space at Westfield Village.  First time tenant.  New 225 A panel with 75kVA 3 phase transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70422	16041-30000-34177	2029 S CENTURY PARK EAST 17th FL-corridor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/27/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Issued	09/27/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in exising high-rise corridor 17th Floor based on 2008 Title 24 code modification in place. Total area: 1,560 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70423	12041-20000-26697	221 S FIGUEROA ST 100	90012	9	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			11/07/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.05628	-118.25373	INTERIOR TENANT IMPROVEMENT OF OFFICE SPACE ON FIRST FLOOR.  Plan check for T-24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70424	13041-10000-35641	10420 S WEIGAND AVE	90002	15	090A217   266	6066009058	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Expired	06/02/2016 12:00:00 AM	ADDRESS	33.94076	-118.22954	PV1, Install 7.5 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Fronius IG Plus A 7.5. (30) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70425	18041-10000-01224	2221 E OLYMPIC BLVD	90021	14	121-5A217 314	5167001058	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/12/2018 12:00:00 AM		Issued	01/12/2018 12:00:00 AM	ADDRESS	34.0262	-118.23242	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70426	19041-10000-47632	100 S MARIPOSA AVE	90004	13	138B197   911	5518009017	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2113.10	Electrical	Electrical	Apartment			11/19/2019 12:00:00 AM			Reviewed by Supervisor	01/13/2020 12:00:00 AM	ADDRESS	34.07249	-118.29924	FULL PLAN CHECK FOR POWER & ENERGY. INSTALLING NEW SERVICE, PANELS & CIRCUITS. (((NEW 36 UNIT APT WITH PARKING GARAGE.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70427	19041-10000-01698	1515 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   315	5036030034	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			Not Ready to Issue	04/01/2020 12:00:00 AM	ADDRESS	34.01101	-118.30407	PLAN CHECK FOR T24 ONLY, REMODEL AND EXPANSION OF AN EXISTING MINI MART AT A GAS STATION. INSTALL NEW LIGHTSA ND POWER FROM TWO EXISTING PANELBOARDS. TOTAL AREA: 1,572 SQ.FT, NEW CONNECTED LOADS < 200ANote. Portion of permit fee is paid under application # 19041-10000-35163(B# 19016-10000-01242)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70428	12041-10000-16969	1694 N ALTA MURA ROAD	90272	11	135B133   184	4432007017	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2012 12:00:00 AM	01/09/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	ADDRESS	34.06407	-118.5013	PLAN CHECK FOR NEW 600 SERVICE UPGRADE AND ELECTRICAL SYSTEM. EXISTING SINGLE FAMILY DWELLING AND ADDITION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70429	13041-20000-29213	14333 W ADDISON ST 1-46	91423	4	171B153   727	2248008039	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			10/21/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.16135	-118.44556	PV2 MULTI FAMILY DWELLING. TOTAL SYSTEM SIZE 15 KW AC USING 70 MODULES. USING 3 CENTRAL INVERTERS. WITH ISOLATION TRANSFORMER. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70430	10041-10000-15258	181 S LA BREA AVE	90036	5	138B181  1248	5513019039	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			08/05/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	03/25/2011 12:00:00 AM	ADDRESS	34.07124	-118.34424	TI IN AN EXISTING 2 STORY BUILDING. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70431	17041-10000-27870	735 S BROADWAY	90014	14	127-5A209  71	5144014031	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.04448	-118.2543	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLYBASEMENT LEVEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70432	18041-10000-38860	14901 W RINALDI ST	91345	7	213B149   309	2664023008	(Q)C1-1VL, (Q)P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	10/11/2018 12:00:00 AM		Issued	10/11/2018 12:00:00 AM	ADDRESS	34.2792	-118.45781	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70433	11041-10000-21210	10000 W PICO BLVD BLDG 5	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00, 2691.00, 2695.00	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	12/15/2011 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.05211	-118.40654	BLDG. NO. 5 (Snack bar section inc. outside lighting) OF POOL HOUSE AT HILLCREST COUNTRY CLUB, POOL HOUSE CONSISTS OF BLDGS. NO. 1, 2, 3, & 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70434	18041-10000-47828	16450 W FOOTHILL BLVD	91342	7	228B137   183	2603007036	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.31882	-118.48831	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70435	18041-10000-47188	6500 W WILSHIRE BLVD 17TH FLR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM			Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.06371	-118.3703	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT OF ENTIRE 17TH FLOOR <EXISTING OFFICE BUILDING.>. TOTAL AREA: 15,902 SQ.FT((B# 18016-10000-35164))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70436	15041-10000-06012	3003 S HILL ST	90007	9	120A205   187	5122010015	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.02256	-118.27325	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70437	12041-20000-17024	323 S LA BREA AVE	90036	4	135B181   254	5508001007	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM			PC Approved	07/20/2012 12:00:00 AM	ADDRESS	34.06816	-118.34422	T-24 lighting plan check for a lighting retail store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70438	18041-20000-17354	17600 W STARE ST	91325	12	204B129   467	2734010002	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Re-Activate Permit	11/07/2019 12:00:00 AM	ADDRESS	34.25296	-118.51782	Plan check for PV roof mounted system, system size: 10.4kWac with 36 modules and 2 inverter(5.2kW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70439	17041-20000-07538	20929 W VENTURA BLVD Building C	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.16667	-118.58906	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 1200-amps.Note: Building application has been generated under 16016-20000-22114	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70440	19041-30000-52506	5670 W WILSHIRE BLVD 2100	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Issued	01/09/2020 12:00:00 AM	ADDRESS	34.06222	-118.35208	PC FOR  ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE INCLUDES NEW LIGHTIGN, CIRCUITS, AND CONTROLS. TOTAL AFFETED AREA IS 6,203 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70441	16041-10001-22117	2239 S VETERAN AVE	90064	5	126B153   659	4322011016	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM			PC Approved	06/30/2016 12:00:00 AM	ADDRESS	34.04114	-118.4336	SUPPLEMENTAL TO AN APPROVED SET OF PLAN. ADDITION OF ONE MOUDULE.<<<<PC FOR ADDITION TO EXISTING PV SYSTEM. TOTAL ADDITION 3KW AC USING 9 MODULES. NEW SUBPANEL ADDED TO COMBINE TOTAL PV OUTPUT.>>>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70442	09041-20001-22504	10452 W BELLAGIO ROAD	90077	5	141B153   212	4362021004	RE20-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2011 12:00:00 AM			PC Approved	06/29/2011 12:00:00 AM	ADDRESS	34.0812	-118.43897	Changes from previously approved to reflect the as-built.  All changes indicate by DELTA-11 as shown on plans.  Plan check for power only.  NOTE:  The changes description will be submitted later by the applicant before plans assign.*****Major Structural Revisions to approved plans with PCIS #08041-20000-15173 (New single family residence (2 story & basement)).*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70443	19041-10000-50972	12659 W MILBANK ST	91604	2	168B161  1022	2362017020	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.15337	-118.40938	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 31 MODULES (SPR-A400-G-AC), 31 MICROINVERTERS (IQ7AS-66-ACM-US),  AND 1 PANEL OF 100 AMPS,  SYSTEM SIZE: 12.4 KW DC; 10.819 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70444	16041-20001-33726	2800 W OLYMPIC BLVD	90006	10	129B197   235	5078013028	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			12/05/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.05242	-118.2951	12/5/19CHANGES TO APPROVED SET DELTA 3 ONLY. CHANGES TO ADD (2) NEW SUBPANELS AND EQUIPMENTS. <<<<Lost plans on  15041-10000-04941 and 10001 is PC infor complete for a 70 unit apartment. ********************************************Plan check for power and energy for new mixed-use apartment building with 4 stories apartment dwelling units. 69 unit apartment with 2500A-rated 208Y/120 service.>>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70445	19041-10000-50647	2224 W 29TH PL	90018	10	120B189   212	5052021002	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	01/30/2020 12:00:00 AM	ADDRESS	34.02807	-118.31542	NEW ROOF TOP SOLAR SYSTEM CONSIST OF 13 MODULES (REC290), 13 OPTIMIZERS (P320) AND 1 CENTRAL INVERTER WITH BUILT IN EV CHARGER (SE3800H-US). SYSTEM SIZE IS 3.8KWAC AND 3.77KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70446	13041-20000-12507	5230 N VAN NUYS BLVD	91401	2	172-5A151 205	2248013009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.16582	-118.44847	Plan check for energy only. Existing emergency lighting. Acura Dealership (showroom, service bays outside scope of work).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70447	17041-10000-31883	1123 S SHENANDOAH ST 1-15	90035	5	132B169   614	4332018042	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			09/06/2017 12:00:00 AM			Reviewed by Supervisor	09/13/2017 12:00:00 AM	ADDRESS	34.05637	-118.38173	PC FOR POWER AND ENERGY FOR A New 4- story 15 units apartment over 1-story basement garage.NEW SERVICE OF 800A 120/240 3PHASE. TOTAL OF 2 TYPICAL UNITSTOTAL AFFECTED AREA 16430 (INDOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70448	11041-10000-12228	12800 W CULVER BLVD	90066	11	105B157   410	4221031009	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/14/2011 12:00:00 AM			PC Approved	06/23/2011 12:00:00 AM	ADDRESS	33.98489	-118.42552	T.I. for offices on the first flor of a two story building.  Relocating some light fixtures as well as adding additional lighting fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70449	18041-20000-35448	11420 N MONTALCINO WAY	91326	12	213B109   404	2701068015	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.2789	-118.58643	27 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70450	19041-10000-04646	555 W 5TH ST	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Approved	04/02/2019 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR ENERGY ONLY. TI  INTERIOR RENOVATION OF EXISTING EMPTY SHELL. SCOPE OF WORK INCLUDES NEW LIGHTING AND POWER FOR A RESTAURANT SPACE IN A HIGH RISE BUILDING. TOTAL SQ. FT. 1000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70451	15041-10001-39758	3658 S RUTHELEN ST	90018	8	120B193  1517	5042017028	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2016 12:00:00 AM			Corrections Issued	05/31/2016 12:00:00 AM	ADDRESS	34.02148	-118.31266	05/31/16PC FOR A LOST SET OF PLANS. PC FOR A NEW SOLAR SYSTEM ON AN EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.5KW.NOTE: PERMIT PULLED UNDER PCIS#15041-10000-39758(((((PV1. NEW SOLAR SYSTEM ON EXISTING ROOF-TOP. TOTAL SYSTEM SIZE IS 2.5KWac. (10)MODULES-BOVIET 260W(1)INVERTER-FRONIUS GALVO 2.5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70452	19041-20001-33731	201 N ASHDALE PL	90049	5	138B145   231	4366008028	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM			PC Approved	10/15/2019 12:00:00 AM	ADDRESS	34.0753	-118.46214	$0 plan check feee due to Sb1222 and AB 1414supplemental plan check only for change to approved set clouded changes only, change to single line conductor size	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70453	15041-20001-35427	18857 W BRAEMORE ROAD	91326	12	216B121   190	2820015010	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM			PC Approved	10/29/2015 12:00:00 AM	ADDRESS	34.29062	-118.54451	***Expedite Fee**PV1, roof mounted solar 3.8 kW AC system.(11) modules: Q-PEAK-BLK-G3-270W(1) inverter: SE3800A-US (240V)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70454	18041-20001-23265	9346 N URBANA AVE	91331	6	198B153   478	2642019010	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2018 12:00:00 AM			PC Approved	06/27/2018 12:00:00 AM	ADDRESS	34.24005	-118.43296	06/27/2018 Plan check for a PV1 roof-mounted PV system. System consists of (1) 6 kWac rated inverter and (20) modules. Standard plan is being used.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70455	15041-10000-40653	4016 W SLAUSON AVE	90043	8	108B181   249	4019001025	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	Commercial			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	33.98876	-118.34468	NEW FA SYSTEM WITH 27 FA DEVICES . FOR A DAY CARE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70456	17041-10000-37843	15600 W ROSCOE BLVD	91406	6	192B141   521	2654040020	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	03/30/2018 12:00:00 AM	ADDRESS	34.2212	-118.47229	TITLE 24 ONLY, RELACE OUTDOOR EXISTNG FIXURES WITH LED FIXURES, TOTAL SQUARE FOOTAGE 18750 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70457	16041-10000-20509	2221 N PARKSIDE AVE	90031	1	138A227   240	5211013024	R3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	Yes	1991.20	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Expired	07/16/2018 12:00:00 AM	ADDRESS	34.07103	-118.20024	PV SYSTEM  TOTAL SYSTEM SIZE 3.8KW AC USING CENTRAL INVERTER WITH 12 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70458	17041-20000-00188	10400 N CAYUGA AVE	91331	7	204B157    90	2620022006	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.25925	-118.42223	Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.3.84kW ungrounded system. (16) EnPhase M250 microinverters. (16) 290W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70459	15041-10000-27903	1505 N EDGEMONT ST 1ST FL	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.09843	-118.29637	IN A MEDICAL OFFICE BUILDINJG, ALTERATIONS IN THE COORRDORS, DRESSING ROOMS, AND WAITING AREA  OF THE IMAGING CENTERPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70460	18041-20001-00832	11970 W VENTURA BLVD	91604	2	162B169   151	2369016034	C2-1VL-RIO, P-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM			PC Approved	07/30/2018 12:00:00 AM	PIN	34.14319764	-118.39263254	07-30-2018 changes to an approved set of plans, Changes include roof equipment layout modified, and panel PM revised load. All changes has been clouded as delta 1. Changes apply to delta 1 only.  Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70461	17041-10000-39336	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.10229	-118.33907	T-24, PC FOR ENERGY ONLY. ALTERATIONS IN A WALGREEN RETAILSTORE. NEW  LUMINAIRES. PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70462	17041-10000-20889	3128 W 8TH ST	90005	10	132B197   466	5094014022	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.06	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/30/2017 12:00:00 AM	ADDRESS	34.05755	-118.29517	PC FOR ICE CREAM SHOP. T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70463	18041-20000-31964	21650 W OXNARD ST 21st flr	91367	3	177B105    83	2146006042	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti to an existing commercial building (High Rise).  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70464	19041-10000-36265	7117 N JORDAN AVE	91303	3	183B105   320	2111024008		South Valley				1345.20	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.19971	-118.60298	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70465	14041-10001-05616	940 S WESTERN AVE	90006	10	132B193  1081	5080008019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.05431	-118.30888	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 5 ON PLANS. CHANGES MADE INCLUDE USE OF TRANSFORMER TO FEED ELEVATORS AND REVISED EMERGENCY LIGHTING. UPDATED T24. THIS IS PERMIT FOR ADDITIONAL TRANSFORMERS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70466	10041-10000-05937	2221 E 16TH ST	90021	14	118-5A217  37	5167012022	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	04/01/2010 12:00:00 AM		Permit Finaled	05/10/2010 12:00:00 AM	ADDRESS	34.02038	-118.23265	NEW SERVICE ,PANELBOARDS, CIRCUITS AND EQUIPMENT FOR EXISTING MANUFACTURING SPACE. NEW LOAD IS ABOUT 302A; SERVICE IS 400A PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70467	19041-10000-07865	20929 W VENTURA BLVD UNIT 41	91364	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM			PC Approved	03/05/2019 12:00:00 AM	ADDRESS	34.16667	-118.58906	ADDING LIGHTING AND EXIT SIGN TO EXISITNG RETAIL SPACE FOR FUTURE TENANTPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70468	11041-20000-18771	12045 W GUERIN ST	91604	2	165B165   989	2368004012	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Apartment			09/02/2011 12:00:00 AM			Plans on Hold	09/30/2011 12:00:00 AM	ADDRESS	34.14635	-118.39389	New 7-unit apartment complex.  A variance for fire alarm has been filed at the time of submittal.  Plan check is or energy and power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70469	15041-20000-02105	226 N LARCHMONT BLVD	90004	4	138B189   556	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.07552	-118.32343	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RITE AID. NEWLY CONNECTED LOAD < 400 AMPS. 9000 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70470	19041-10000-14197	11345 W OLYMPIC BLVD	90064	11	126B153  1053	4260002019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM			PC Info Complete	04/18/2019 12:00:00 AM	ADDRESS	34.03796	-118.44202	PLAN CHECK FOR TITLE 24 ONLY TENANT IMPROVEMENT OF (E) BANK.  (REMODEL BATHROOMS, BREAK ROOM, NEW PARTITIONS, REPLACE ATM). TOTAL EFFECTED AREA 7110 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70471	19041-20000-08474	385 W 20TH ST	90731	15	012B201   677	7456034010	MR1-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	08/26/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	33.72593	-118.28543	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to agricultural growing and office. Total lighting area = 2,118 sq. ft.Note: Building application has been generated under 18016-10000-18444.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70472	19041-10000-28770	1170 S LA BREA AVE G1	90019	10	132B181  1202	5084021015	C2-1	Central	Wilshire	Olympic Park		2161.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.0541	-118.34323	PC for Methane mitigation system (Lever 4), 1 fire alarm panel, 1 power supply and 12 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70473	18041-10000-12153	672 N PALISADES DR	90272	11	129B117    35	4419015***	(Q)RD3-1, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Apartment			04/04/2018 12:00:00 AM			Reviewed by Supervisor	04/11/2018 12:00:00 AM	ADDRESS	34.0494	-118.55219	INSTALLATION OF ENERGY STORAGE SYSTEM. 27 KWH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70474	19041-20000-49801	19301 W VANOWEN ST	91335	3	183B117   994	2130017003	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.19397	-118.55381	Plan check for Title 24 Energy only existing sign lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70475	13041-10000-35406	6904 N VANTAGE AVE # 127	91605	2	183B165   722	2321010***	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	01/29/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.19578	-118.39751	PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformered inverter: FRONIUS IG 3000 NEG. (10) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70476	19041-20000-52786	8405 S PERSHING DR	90293	11	096B153   927	4116023022	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	09/17/2020 12:00:00 AM	ADDRESS	33.95705	-118.4431	PV3.  Install 22.62 KW DC/15.2 KW AC roof mounted grid tied PV system.  (58) modules with (2) 7.6 kW rated inverters and a pv panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70477	18041-10000-48549	2188 N MANDEVILLE CANYON ROAD	90049	11	138B133   495	4493003023	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM			PC Approved	02/21/2019 12:00:00 AM	ADDRESS	34.07625	-118.49931	*** FEE ESTIMATE ONLY ***   (N) 3 STORY SFD. Plan check for power only, 1200A 120/208V 3ph, 4W service rating. (2) dist. board, (13) panelboards, (1) 125kW generator. This is plan check only, electrical permit is covered under combo Building Permit # 16010-10000-04870 ((B# 16010-10000-04870 - Main House,  B# 16010-10000-04871 - Rec. Room,  B# 16041-10000-04872 Utility & Storage structure))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70478	18041-20001-22816	4095 S GLENCOE AVE	90292	11	108B153  1121	4230005046	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			PC Approved	01/18/2019 12:00:00 AM	ADDRESS	33.98972	-118.44276	Expedited per applicant request.Plan check for a PV2 roof-mounted PV system. System size is 72 kWdc/65 kWac and consists of (2) 28 kWac rated inverters, (180) modules, (1) load center, and (1) transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70479	17041-10000-35350	3278 W WILSHIRE BLVD	90010	10	132B197    44	5094008030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	01/22/2018 12:00:00 AM	ADDRESS	34.06162	-118.29366	PC FOR OUTDOOR T-24, REPLACE EXISTING FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 15,125	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70480	19041-30000-47658	940 E 4TH ST	90013	14	127-5A215 230	5163021001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.04337	-118.23511	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS 40 DEVICES WITH A NEW FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70481	19041-20001-45661	6025 N MORELLA AVE	91606	2	177B169   718	2334016032	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.18024	-118.39009	12/12/19CHANGES TO APPROVED SET CHANGES TO RELOCATION OF MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70482	14041-20000-11182	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.08363	-118.32191	UPS replacement for stage 30 on paramount picture lot.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70483	12041-20000-00977	300 S GRAND AVE 11th Floor	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM	01/19/2012 12:00:00 AM		Permit Finaled	05/04/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to a high rise building on 11th floor of room numbers 1100-1105, 1129-1133, and 1113-1115 as indicated on plans.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70484	16041-30001-20270	18981 W VENTURA BLVD	91356	3	174B121   401	2163020020	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.17265	-118.5472	EXPEDITE PER APPLICANTPV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 34KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70485	11041-20000-23071	13557 W HATTERAS ST	91401	2	174B157   145	2343004017	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	12/15/2011 12:00:00 AM	ADDRESS	34.17579	-118.42861	New 5.4 KW roof mounted PV system for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70486	14041-10001-15250	1930 W WILSHIRE BLVD 14th floor	90057	1	132A203    41	5142002019	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.05713	-118.27464	Changes to the approved set of plan, changes under delta 2. Changes includes: changes of main lug  and change of feeder  size.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70487	14041-20001-24839	7010 S HOOVER ST Unit #6	90044	8	102B201   668	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97574	-118.28691	expedite feespv2 commercial rooftop solar. using Enphase m250 modules with 5 modules in total. System connects to unit subpanel. This application is for Unit #6. total system size 1.25kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70488	16041-20002-11729	648 N MARTEL AVE	90036	5	141B181   607	5526020027	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			06/01/2016 12:00:00 AM			PC Approved	06/01/2016 12:00:00 AM	ADDRESS	34.08325	-118.35098	06/01/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****Plan check Title 24 only for existing space. Total area: 1,019 sq ft. {{{{{{Run new 8 lines to subpanelInstall 15 outletsInstall 2 recessed lightsInstall 2 bathroom fans}}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70489	12041-10000-14095	18121 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	34.2647	-118.52646	T.I. to an existing Dental Space, building is not licensed by the state, NOT checked for OSHPD.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70490	13041-10000-07844	1666 S GREENFIELD AVE 1-10	90025	5	129B153   588	4324030012	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			03/27/2013 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	34.04918	-118.44155	NEW FIREALARM SYSTEM FOR APARTMENT BUILDING. 41 DEVICES, 1 FIRE ALARM PANEL, 1 ANNUNCIATOR PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70491	11041-10000-15885	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	07/28/2011 12:00:00 AM		Permit Closed	12/11/2015 12:00:00 AM	ADDRESS	33.96577	-118.42406	NEW FIRE ALARM SYSTEM FOR AN EXISTING 2-STORY COMMERCIAL BUILDING.  NORTH HALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70492	16041-10000-44683	3686 N BARHAM BLVD (BUILDING-H)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.13988	-118.34132	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70493	17041-10000-26099	13535 W VICTORY BLVD	91401	2	180B157   918	2329005018	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.20	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Issued	08/01/2017 12:00:00 AM	ADDRESS	34.18683	-118.42799	TITLE 24 PLAN CHECK FOR REMOVAL OF (5) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA = 5400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70494	15041-10000-25384	3651 S WATT WAY 7th Floor-Lab	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	02/11/2016 12:00:00 AM	ADDRESS	34.02013	-118.28812	PLAN CHECK FOR ENERGY ONLY FOR VIVIAN HALL 7TH FLOOR LABORATORY ONLY. 470 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70495	18041-10001-16540	2025 S AVENUE OF THE STARS	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	03/18/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	"PC FOR CHANGES TO APPROVED SET. CURRENT CHANGES ARE NOTED AS DELTA-5.SCOPE INCLUDES NEW PANEL, CIRUCUITS AND EQUIPMENT FOR THE ""GOLD LOUNGE"". ADDTIONAL CHANGES TO T-24 AND LIGHTING FIXTURES. <"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70496	19041-20000-43186	11601 W WILSHIRE BLVD Ste 325	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.05075	-118.45961	Power and lighting for (E) commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70497	12041-10000-23251	11928 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	09/28/2012 12:00:00 AM	ADDRESS	34.05236	-118.4707	Title 24 forretail stor one story.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70498	13041-20001-24675	1214 N TURQUESA LANE PV-1	90272	11	132B121   326	4420024037	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM			PC Approved	10/09/2013 12:00:00 AM	ADDRESS	34.05691	-118.54825	EXPEDITE FEEPV-1. 26.6kW AC (two 11.4kW inverters and one 3.7kW inverter). Large inverters are grounded DC and smaller transformer is transformerless.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70499	13041-20000-13425	1923 S BRONSON AVE	90018	10	126B185  1048	5060006013	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.01	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	ADDRESS	34.03922	-118.33029	T24 FOR EXISTING RESTAURANT SPACE. 1030 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70500	15041-10000-19076	523 W 6TH ST SUITE 205	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	TI TO AN EXISITNG HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 2360. SCOPE OF WORK TO BE IN SUITE 205.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70501	13041-10000-30211	800 W WILSHIRE BLVD 16th Floor	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	34.0493	-118.25841	Commercial office TI on the 16th floor (tenant occupies entire floor) of a highrise building.  Title 24 plan check only for changes to lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70502	18041-20000-26498	1117-1121 N SEWARD ST	90038	4	144B185   601	5532023016	[Q]M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/16/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	10/05/2018 12:00:00 AM	ADDRESS	34.09126	-118.33335	new fire alarm system with 86 devices and (1) facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70503	17041-10000-16675	1404 N CATALINA ST	90027	13	147B197  1085	5543017018	C2-1, [Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	05/22/2018 12:00:00 AM		Issued	05/22/2018 12:00:00 AM	ADDRESS	34.09676	-118.29487	Plan check for power and Title 24.  T.I. to basement, ground floor, and first floor of existing mixed use building (dormatory, office, retail).  Existing service and distribution panels to remain with new subpanels.  New lighting, receptacles, and equipment.  Total area = 103,633 sq. ft.       Building permit #15016-10000-10820	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70504	12041-20000-15348	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.05903	-118.41293	T.I. to a high rise building on 36th floor (Suite #3630).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70505	18041-10000-16404	1800 N HIGHLAND AVE FLR 1, 3	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM			PC Info Complete	05/03/2018 12:00:00 AM	ADDRESS	34.10436	-118.33763	Energy plan check for offices T.I. Scope include new lighting and equipment located in the 1st and 3rd floor of a high rise building. Total area is 17015-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70506	10041-10000-13618	10967 W SANTA MONICA BLVD	90025	5	129B153   608	4324030016	[Q]C2-1VL-O	West Los Angeles	Westwood			2655.20	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	09/23/2010 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.04898	-118.44064	Upgrade electrical service from 400 A to 600 A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70507	19041-10000-05259	9333 N MELVIN AVE	91324	12	198B117   121	2761036046	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.24024	-118.56026	$0 fee per AB1414. PLAN CHECK FOR 52KWac ROOF MOUNTED PV SYSTEM CONSISTING OF 5 INVERTERS((4)FRONIUS 10.0 AND (1)FRONIUS 12.0) WITH 174 MODULES(TRINA TSM-DD114A(11)340W)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70508	15041-10000-06533	837 N SPRING ST 3rd Floor	90012	1	135A215   314	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM	05/01/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	PIN	34.06296813	-118.23676788	TI to (E) 3rd floor commercial office tenant space in (E) lowrise commercial building.  Plan check for power and energy -connected load exceeds 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70509	12041-10000-00469	5257 W WASHINGTON BLVD	90019	10	126B177   813	5064003011	[Q]C2-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			01/09/2012 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Expired	02/03/2014 12:00:00 AM	PIN	34.04152509	-118.35610672	Plan check T24 Energy/Emergency lighting for commercial building TI.   PERMIT FOR 10 NEW CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70510	11041-10000-14255	2512 S FIGUEROA ST	90007	9	121-5A203  25	5124027016	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM			PC Approved	07/27/2011 12:00:00 AM	ADDRESS	34.02871	-118.27541	T.I.  Existing 7-11.  Replacing existing fluorescent lights with LED on the retail floor.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70511	12041-10000-26181	271 S MAPLETON DR	90024	5	138B153    12	4359010016	RE40-1	West Los Angeles	Westwood	Bel Air - Beverly Crest, Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.07827	-118.43247	New single family house with 1600A service.  Plan check for power.10/31/12 Copied from estimate created in Van Nuys 12041-20000-18198	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70512	11041-10000-04332	14823 W SYLVAN ST	91411	6	178-5A149  56	2241008018	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Apartment			03/07/2011 12:00:00 AM	07/20/2011 12:00:00 AM		Permit Finaled	01/07/2014 12:00:00 AM	ADDRESS	34.18482	-118.4562	NEW 9 UNIT APARTMENT BUILDING.  9 NEW PANELS, NEW SERVICE.  3 STORY BUILDING.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70513	17041-10000-39220	2500 N TAPER AVE	90731	15	027B193   151	7442001007	OS-1XL, R1-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	9800.15	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	33.76677	-118.29939	PC for T24 only for replacement of existing fixtures with LED fixtures. Total area 172100sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70514	18041-20001-14613	6442 N WHITAKER AVE	91406	6	180B137   586	2231002012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2018 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.18798	-118.49807	expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70515	17041-10000-04455	"4550 N VAN NUYS BLVD Unit ""B"""	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	PC for energy only. TI on vecant retail space, ice cream shop (Afters store). New lighting and Power. Area: 1125.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70516	17041-20001-46640	6020 N MELVIN AVE	91356	3	177B117   614	2153028029	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2017 12:00:00 AM			PC in Progress	01/06/2018 12:00:00 AM	ADDRESS	34.17999	-118.55979	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted solar array on SFD.11.04kW ungrounded system.(48) EnPhase IQ6-60 microinverters.(48) 300W pv modules.Derating main breaker from 200A to 175A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70517	16041-10000-18197	5419 S 6TH AVE	90043	8	108B189   752	5006023030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	33.99251	-118.32375	PV1 , INSTALL NEW 7.42 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(28) MODULES: KYOCERA KU2656ZPA (1)INVERTER: ABB PVI-6000-OUTD-US -Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70518	14041-10000-04158	2348 N ARTHUR ST	90065	1	151-5A217 202	5456003016	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.10984	-118.23236	PV1, Install 3.75 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 3800A-US-ZB-U. (15) Modules: CANADIAN SOLAR CS6P-250PX.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70519	13041-20000-28624	3587 S OCEAN VIEW AVE	90066	11	114B153   664	4248025041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Expired	11/10/2015 12:00:00 AM	ADDRESS	34.00879	-118.43601	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING 28 MODULES. USING ENPHASE MICROINVERTER. STANDARD PLAN. 2 STRINGS.(((FIELD VERIFY MAIN SERVICE 200A. IF 400 THEN RETURN TO PLAN CHECK)))	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70520	14041-20002-07630	6900 N WINNETKA AVE	91306	3	183B113   690	2135030006	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	34.19574	-118.57078	ROOF PLAN LAYOUT CHANGE APPROVED BY FIRE DEPT.  $0 PLAN CHECK SUBMITTAL FEE IS DUE TO SENATE BILL SB-1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70521	13041-20002-27430	13031 W JEFFERSON BLVD Suite 600	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Expired	07/26/2016 12:00:00 AM	ADDRESS	33.97451	-118.42531	Changes from previously approved plans.  Reduce the number of racks in the server room, and revise the panel loads to provide dedicated 30A branch circuits to supply those racks.  No changes in lighting.  Plan check for power only.****Previous Supplemental Description *****Changes from previously approved.  Changes include location of equipment and load calculation.  Plan check for power only. no permit to be issued from this application*****Previous Description*****TI to an existing office building.  New panels, loads, lighting.  Load is greater thank 400 amps.  FULL PLAN CHECK.  Permit fees are $30,428.13	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70522	12041-20000-21763	1936 E 1ST ST	90033	14	129A221   303	5174016031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.04587	-118.21637	"New medical dialysis office in an existing building.  Change of use.  New sub-panels, circuits, and lighting.  Full plan check.  Site is in a methane buffer zone.  Building is an ""I"" occpancy and is checked for OSPHD3."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70523	15041-20000-42892	20269 W VIA MADRIGAL	91326	12	219B113   286	2701061026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.29625	-118.57526	Plan check for PV roof mounted system. System size: 7.6kWac with 31 modules and 2 inverters(3.8kW ) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70524	15041-20000-22498	13771 N DE GARMO AVE	91342	7	228B145   176	2603021020	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	34.32169	-118.47143	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (20) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70525	19041-10000-45767	12358 N SAN FERNANDO ROAD	91342	7	219B149   599	2507007015	P-1-CPIO, [Q]M1-1-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.29548	-118.45341	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY INDOOR/OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70526	14041-10000-07952	1619 W 10TH ST	90732	15	015B193   851	7560020014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2970.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	33.73508	-118.31277	PV1,INSTALL 3.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(15) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70527	11041-10000-02537	8100 W WESTCHESTER PKWY	90293	11	093B157    78	4117036900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2766.02, 2780.00	Electrical	Electrical	Commercial			02/09/2011 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	04/27/2011 12:00:00 AM	ADDRESS	33.95164	-118.43579	New Temp. power for Phase 2 & 3. of LAX. EPC is for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70528	18041-20000-10091	1836 N SICHEL ST	90031	1	135A223    84	5210013029	R3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Apartment			03/20/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.06503	-118.21269	New fire alarm system for 27-unit apartment building.  FACP with 122 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70529	11041-10000-06289	633 W 5TH ST 36TH FL	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/30/2011 12:00:00 AM			PC Approved	03/30/2011 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 3 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70530	16041-10000-43648	244 S SAN PEDRO ST	90012	14	129A213   168	5161020019	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.04787	-118.24192	PC FOR ENERGY ONLY. REMOVE HID FIXTURES AND RPLACE WITH NEW LED FIXTURES. TOTAL (OUTDOOR) AREA 66500 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70531	11041-10000-07823	13708 W OXNARD ST	91401	2	177B157   899	2246008023	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00, 1286.00	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	09/02/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.17925	-118.43178	T.I.  NEW 7-ELEVEN TO TAKE OVER AN EXISTING CONVINEANCE STORE. iNSTALLING 4 NEW PANELS, 4 TRANSFORMERS TO BOOST VOLTAGE TO 240 V ( BUCK BOOST).  FULL PLAN CHECK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70532	15041-10000-43717	2865 W 7TH ST	90005	1	133-5A201 146	5077014024	C2-2	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.05993	-118.28599	TI TO AN EXISITNG TWO STORY COMMERCIAL BUILDING ( PARTIAL FIRE REPAIR) WITH SERVICE UPGRADE TO 800 AMPS. FULL PLAN CHECK FOR POWER AND ENERGY.  NOTE TO PLAN CHECKER:  APPLICANT NEEDS TO SUBMIT TO BUILDING, VERIFY BEFORE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70533	15041-10000-14732	4151 W PROSPECT AVE 1ST FL	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			05/14/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	09/29/2015 12:00:00 AM	ADDRESS	34.10191	-118.28217	TI- 24 TO AN (E) RESTAURANT BUILDING RE LOCATING (E) LIGHTS. PC FOR ENERGY ONLY. TOTAL SQ. FT. 2489 .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70534	18041-10000-43499	8340 N VAN NUYS BLVD	91402	6	192B149   292	2638022061	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.22301	-118.44856	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70535	19041-20000-12514	10351 W SANTA MONICA BLVD Suite 200	90025	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.05844	-118.42319	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 3,219 sq. ft.Note: Building permit has been issued under 19016-10000-01959	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70536	12041-10000-16876	1470 E 4TH ST	90033	14	127-5A219 373	5171008002	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	12/03/2012 12:00:00 AM		Permit Finaled	06/13/2013 12:00:00 AM	ADDRESS	34.04221	-118.22429	PLAN CHECK POWER AND ENERGY FOR UPDATING EXISTING CENTER COOLER. NEW 2000A SERVICE AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70537	19041-10000-45319	6353 N VAN NUYS BLVD	91401	6	180B149  1035	2241004007	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	05/14/2021 12:00:00 AM		Permit Finaled	08/11/2022 12:00:00 AM	ADDRESS	34.18585	-118.44901	TENANT IMPROVEMENT. T-24 ENERGY PLAN CHECK. TOTAL AFFECTED AREA 7300sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70538	11041-20000-14005	15760 W VENTURA BLVD SUITE 1150	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM	07/06/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	ADDRESS	34.1552	-118.47684	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR T.I.  RELOCATE AND REPLACE EXISTING LIGHT FIXTURES. PERMIT FOR NEW CKTS, PANEL, AND LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70539	13041-10000-35345	2612 N ROUND DR	90032	14	141A235   413	5217012014	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/15/2014 12:00:00 AM	ADDRESS	34.07852	-118.17236	PV1, Install 5 kW DC roof-mounted solar array, interconnect with main service panel for a one story house. (1)Transformerless inverter: Solaredge SE 5000A-US. (20) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70540	15041-10000-42435	13341 W KILLION ST	91401	4	174B157   680	2344014056	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	01/04/2016 12:00:00 AM	ADDRESS	34.17125	-118.42395	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 18.9KW INTERCONNECTED WITH MSP.(63) REC SOLAR MODULES275(63) POWER OPTIMIZERS P300(2) SOLAREDGE 7600 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70541	13041-10000-35000	11554 N LYSTER AVE	91326	12	213B121   265	2871011014	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2013 12:00:00 AM	12/17/2013 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.28192	-118.54146	PV1.  Install 4.75 kW AC roof-mounted PV system.  Microinverters: Enphase M215.  22 modules: Solar World Sun Module SW250Poly	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70542	10041-10000-03551	5331 E HUNTINGTON DR NORTH	90032	14	145-5A237 252	5309017020	(T)[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2011.20	Electrical	Electrical	Apartment			03/01/2010 12:00:00 AM			PC Approved	05/04/2010 12:00:00 AM	ADDRESS	34.09124	-118.16464	layout out of original plan checked ( 09041-10000-19704 )  types of  apartment units have changed resulting in new plan check of revised plans. Hourly rates is charged with permit obtained for items shown on original application. Note that correction was pending on original submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70543	14041-20000-33431	21725 W VICTORY BLVD	91303	3	180B105    77	2139004045	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/03/2014 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.18791	-118.60217	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CHANEL KIOSK INSIDE (E) NORDSTROM. TWO LEVELES. TAILORED METHOD. 2074 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70544	16041-10000-22592	331 1/2 E 1ST ST	90012	14	130-5A215 321	5161012012	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM			PC Approved	06/28/2016 12:00:00 AM	ADDRESS	34.04992	-118.23998	COFFEE SHOP. NEW LIGHITNG. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70545	14041-10000-28258	5057 W WASHINGTON BLVD	90019	10	126B181   889	5067016014	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			10/14/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	PIN	34.04114399	-118.34989775	Title 24 plan check only.  Total area = 10750 sq. ft.T.I. to existing commercial space.  Installation of new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70546	19041-10000-26776	627 S SAN JULIAN ST	90014	14	127-5A213 434	5148024018	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.04231	-118.24675	Plan Check for T24 only, TI of entire 2 story building to divide space into offices, break rooms, restrooms, and lobby. Dist. board is existing 400A, add 2 new panels and elevator, new connected load is less than 200A.Toatl area under the scope is (5242 indoor + 686 outdoor = 5,928 sq.ft) - Emenrgecy power to be suplied by Inverter see panel schedule	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70547	13041-10000-20256	8290 W SKYLINE DR	90046	4	156B169   425	5564008020	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.12026	-118.39069	PV1 8.82KW 240V XFMR INV. 2STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 36) MOD: TRINA {TSM-250PA05.08}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70548	15041-10000-18135	10569 W PICO BLVD	90064	5	126B157   288	4320013019	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM	06/11/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.04403	-118.42136	TI TOAN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 1445.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70549	13041-10000-17733	14682 W TYLER ST	91342	7	225B149   429	2505024032	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.31038	-118.45288	ROOF MOUNTED P.V. RESIDENTIAL INSTALLATION. 26 MODULES, 26 MICRO INVERTERS 6.50 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70550	14041-10000-20054	8011 N WEBB AVE	91605	6	189B169   196	2310008005	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.21614	-118.3884	PC for energy only.  Replace HID light fixtures with new fluorescent fixtures.Total area 4320 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70551	12041-20001-27760	2415-2423 W WASHINGTON BLVD	90019	10	126B189   912	5073020002	[Q]CM-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	PIN	34.04012498	-118.3148908	((((CHANGES MADE TO APPROVED SET OF PLANS. INCREASED CODUIT SIZES AND REMOVAL OF TIME CLOCK TO OCCUPANCY SENSOR. MAKING CHANGES ON PERFERATED SET PER APPLICANT REQUEST. PLAN CHECK ONLY))))Core and shell building with no parking space.  New overhead 600 Amp service.  Methane Zone.  Plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70552	10041-10000-22658	1230 W 3RD ST 4TH Flr	90017	1	132A209    97	5152014037	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	03/13/2012 12:00:00 AM	ADDRESS	34.057	-118.259	TI IN AN EXISTING OFFICE AREA ON THE 4TH FLOOR FOR RELOCATING EXISTING LIGHT FIXTURES. PLAN CHECK IS FOR T-24 ENERGY CALCS.   PERMIT IS FOR NEW CIRCUITS AND COMMUNICATION OUTLETS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70553	19041-10000-16970	13164 W BURBANK BLVD	91401	4	174B157   656	2345005022	C2-1, R1-1, R3-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.17196	-118.4201	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70554	19041-10000-32892	11216 W SATICOY ST	91352	2	186B173   300	2315015030	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2019 12:00:00 AM			PC Approved	08/21/2019 12:00:00 AM	ADDRESS	34.20831	-118.3753	Plan check only, for a 3.8KWac system on a single family rooftop. Scope of work is 14 modules (Hanwha Q-cells 325), with optimzers (SE P370) and central inverter (SE3800H-US). Note permit has been pulled under 19041-90000-31770	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70555	14041-20002-02711	10625 N OAKDALE AVE	91311	12	207B113   141	2708020032	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM			PC Approved	04/14/2014 12:00:00 AM	ADDRESS	34.26315	-118.5671	Modifications to approved set: change in proposed design roof module layout.  $0 submittal fee is due to the 2012 Senate Bill No. 1222(((PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 17KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. CONNECTION TO 400A SERVICE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70556	16041-10000-17122	8062 N TYRONE AVE	91402	6	189B153   151	2212016001	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM	05/17/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.21788	-118.44321	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.84KWdc / 6.72kWac.(28)MODULES-HYUNDAI 280(28)MICROINVERTERS-ENPHASE M250Standard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70557	18041-20000-10455	21600 W OXNARD ST 8th Floor	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.179	-118.6002	New lighting in (E) 8th floor corridor of commercial highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70558	10041-10000-07369	4729 N LANKERSHIM BLVD	91602	2	168B173   658	2421026004	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM			PC Approved	04/22/2010 12:00:00 AM	ADDRESS	34.15633	-118.3697	TENANT IMPROVEMENT IN EXISTING OFFICE AREASPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70559	15041-10001-30148	4505 S GLENCOE AVE	90292	11	105B153    96	4212007009	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM			PC Approved	02/24/2017 12:00:00 AM	ADDRESS	33.98462	-118.43495	Changes to approved set.Permit was pulled under original application. PLANCHECK ONLY.Ti, pc for energy only to an existing commercial 2 story bldg (offices). Scope of work: adding new branch circuits, lighting, receptacles and motors. Sq ft = 11350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70560	14041-10000-06470	16821 W LIVORNO DR	90272	11	126B121   137	4415014008	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.04433	-118.54534	PV1, INSTALL 8.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME, INTERCONNECT WITH  MAIN SERVICE PANEL.(34) MODULES: CANADIAN SOLAR CS6P-250PX(2) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70561	17041-10000-32528	9521 S HAAS AVE	90047	8	093A191    90	6057014017	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	33.94934	-118.31684	Remove HID fixtures and replace with new LED fixture  - Title 24 only. Total affected area 22000sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70562	19041-20000-45351	5923 N LAUREL CANYON BLVD #1-11	91607	2	177B165   946	2340006015	R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			11/05/2019 12:00:00 AM	11/12/2020 12:00:00 AM		Permit Finaled	02/10/2022 12:00:00 AM	ADDRESS	34.17798	-118.3967	800A 240/120V 3ph-4w service, distribution, power, and lighting	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70563	18041-10001-34312	1043 S ABBOT KINNEY BLVD	90291	11	108B145   979	4239021019	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM			PC Approved	10/30/2019 12:00:00 AM	ADDRESS	33.99203	-118.47099	CHANGES TO APPROVED SET BY ELIMINATING THE SECOND FLOOR LIGHTING PLAN, SOME EQUIPMENT IS ALSO BEING RELOCATED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70564	14041-20000-24223	18822 W SALT LAKE PL	91326	12	210B121   504	2717002049	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.27043	-118.54392	SFD. PV1. SYSTEM SIZE 6.4KW AC USING MICROINVERTER ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70565	12041-10000-22364	738 N WILCOX AVE 1 - 10	90038	4	141B185   511	5533034013	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			09/19/2012 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.08463	-118.33083	"NEW ""L"" SHAPE 3 & 4 STORIES 103 UNITS APARTMENT BUILDING. FIRE ALARM VARIANCE HAS BEEN FILED."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70566	18041-10000-44209	1624 N CAHUENGA BLVD	90028	13	148-5A187 217	5546008006	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	10/30/2019 12:00:00 AM	ADDRESS	34.10071	-118.32937	In an existing new branch circuits for  power and lightingplan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70567	19041-20001-09945	19231 W VICTORY BLVD unit 100	91335	3	180B117   799	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM			PC Approved	08/30/2019 12:00:00 AM	ADDRESS	34.18678	-118.55214	Revisions to approved set.  Removal of EM lighting from patient care rooms.  (((ti to an existing commercial space (dental office).  plan check for power and energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70568	11041-20000-23308	4520 N VAN NUYS BLVD	91403	2	168A151   188	2265013025	C2-1VL, P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	12/19/2011 12:00:00 AM	ADDRESS	34.15371	-118.4485	PLAN CHECK T24 ENERGY FOR TI NEW PHARMACY OF EXIST RETAIL MARKET	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70569	15041-20000-07764	12655 W JEFFERSON BLVD	90066	11	102B161    13	4211005019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	33.97916	-118.41469	FIRE ALAMR PLANCHECK FOR REPLACEMENT OF FIRE ALARM CONTROL PANEL AND ADDING  155 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70570	14041-10001-34704	2047 S SAWTELLE BLVD	90025	11	126B153   859	4261033022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	34.03973	-118.44287	Modifications to approved set.  Change of lighting fixtures with updated Title 24 forms.  (((982 sq. ft. (E) restaurant TI.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70571	19041-20001-25140	1318 N BEVERLY GLEN BLVD	90077	5	147A153   458	4371030014	RE15-1-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM			PC Approved	08/23/2019 12:00:00 AM	ADDRESS	34.09704	-118.44109	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA A ONLY, CHANGES ON RELOCATION OF LOAD CENTER AND GATEWAY RELAY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70572	17041-10000-14071	8232 N CANTERBURY AVE	91352	2	192B161   208	2304002001	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.22085	-118.41717	PC FOR PV SYSTEM USING MICROINVERTERS. 50 MODULES. 16KW AC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70573	13041-20000-00567	11809 W ROSE AVE PV-1	90066	11	117B153   416	4250003002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Expired	07/03/2015 12:00:00 AM	ADDRESS	34.01806	-118.43674	"PV-1. Marcus Residence. 6.76kW. Transformerless with ""Power Optimizers"".  One single string of 25 modules."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70574	18041-20000-19733	11840 W FOOTHILL BLVD UNIT 'D'	91342	7	210B165   277	2532017035	C2-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.27347	-118.39434	First time tenant for commercial tenant space.  Existing distribution equipment.  2140 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70575	14041-10000-08263	6725 W SUNSET BLVD SUITE 350	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood, Empowerment Congress Southeast Area		1907.00	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.09814	-118.33717	permit to be pulled at EPC counter only. Plan check for energy only. Less than 400A. Emergency lighting.Bldg# 14016-10-04611: T.I. WORK ON (5,084 SQFT) OF 165' x 35' THE TOTAL FLOOR AREA.  NEW WALL, POWER, LIGHTING AND FINISHES. INTERIOR WORK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70576	18041-20000-48721	10252 N TUNNEY AVE	91324	12	204B117   203	2726016001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.25689	-118.55782	Plan check for PV roof mounted system, system size: 11.8kW DC, 10.098kW AC with 33 PV Modules and 33 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70577	19041-10000-43397	2232 S HARVARD BLVD	90018	8	123B193   219	5058018003	RD2-1-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	10/24/2019 12:00:00 AM		Permit Finaled	07/18/2020 12:00:00 AM	ADDRESS	34.03513	-118.30636	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70578	19041-20002-28109	19864 W FALCON CREST WAY	91326	12	217-5A115 120	2701025015	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	34.28944	-118.5668	12/19/19CHANGES TO APPROVED SET ADD AN AC DISCONNECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70579	14041-10000-04548	362 N TEMESCAL CANYON ROAD	90272	11	126B125   285	4413025902	OS-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.03773	-118.53369	(N) chemical treatment building with pumps for stormwater treatment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70580	16041-10000-01167	188 S JUNE ST	90004	4	138B185   422	5515002009	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.07145	-118.33464	PERMIT FEE $0.00 BY STATE SENATE BILL NO.1222PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 22.05kWdc / 22.4kWac.(70)MODULES-LG ELECTRONIC LG315N1C-G4(2)INVERTERS-SMA AMERICA SB-7700TL-US-22 AND (1)INVERTER-SMA AMERICA SB-7000TL-US-22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70581	12041-20001-30775	22622 W VANOWEN ST	91307	12	180B097    33	2038020063	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Info Complete	06/20/2013 12:00:00 AM	ADDRESS	34.19355	-118.61959	"Modification to previously approved set of plans.  Not all changes are clouded.  New panels, relocate circuits, new additional ""existing"" circuits, change to lighting, & loads.            <<<<Electrical and energy for a remodel of A PRIVATE  HIGH SCHOOL BUILDING WITH CLASSROOMS, ADMIN. OFFICES AND OTHER ACADEMIC SUPPORT SPACES. >>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70582	13041-10000-15096	18251 W ROSCOE BLVD	91325	12	192B125   630	2786015018	(Q)CR-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM			PC Approved	06/10/2013 12:00:00 AM	ADDRESS	34.22097	-118.53126	2-story commercial building TI.  Scope of work to be normal and emergency lighting on first and second floor common area corridors.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70583	17041-20001-04837	6431 N INDEPENDENCE AVE	91367	3	180B109   592	2149003039	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/14/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.18737	-118.59079	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70584	17041-30000-38271	1900 S AVENUE OF THE STARS Ste 1400	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM			PC Approved	10/24/2017 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check for Title 24 only. Project site is the 14th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,831 sq. ft.Note: Building permit has been issued under 17016-10000-26707	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70585	16041-10000-27203	14125 W BURTON ST	91402	6	192B153   870	2212020018	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	08/02/2016 12:00:00 AM		Permit Finaled	09/21/2016 12:00:00 AM	ADDRESS	34.22077	-118.44083	PV1 roof mounted solar installation to a sigle family home.  Total system size = 5 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70586	11041-20000-25109	2910 W BEVERLY BLVD seiu-ultcw	90057	13	138A201   357	5155004023	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM	ADDRESS	34.07099	-118.28068	Ti seiu ultcw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70587	14041-20000-32539	7238 N LOMA VERDE AVE	91303	3	186B109  1017	2112017007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Expired	12/16/2016 12:00:00 AM	ADDRESS	34.20225	-118.58944	PV1Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size: 4.3kW. Ungrounded system.20 EnPhase M215-IG microinverters with 20 250W pv modules across two strings (17+3).Note: the solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70588	18041-20000-11355	20433 W NORDHOFF ST	91311	12	195B109    61	2781001036	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.232	-118.57867	Plan check for a PV2 roof-mounted PV system. System size is 66.6 kWac and consists of (2) inverters, (233) modules, (1) transformer, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70589	17041-20000-16166	7639 N VAN NUYS BLVD	91405	6	186B149    98	2210031012	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			05/15/2017 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	10/27/2021 12:00:00 AM	ADDRESS	34.20965	-118.44912	Plan check for power and energy. Project site is a new 5-story apartment building: 4 levels of residential over 1 level of parking garage and 1 level of basement parking garage. Work includes a new 1,200 amp service and a total lighting area of 29,216 sq. ft.Note: Building application has been generated under 16010-20000-05567	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70590	13041-10001-32600	14955 W SATICOY ST 1-106	91405	6	186B145    79	2209038048	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			11/20/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.20859	-118.45912	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM FOR AN APARTMENT COMPLEX. 6 STRINGS. NEGATIVELEY GROUNDED.(336) ECOSOLARGY (1) SOLECTRIA PVI-75KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70591	15041-10001-03979	635 W CRESTMOORE PL	90291	11	108B149  1435	4237012002	R2-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM			PC Approved	03/12/2015 12:00:00 AM	PIN	33.98921101	-118.45637675	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70592	17041-10000-32834	1526 N EDGEMONT ST 6TH FLR	90027	13	147B197   578	5543010017	C2-CSA1, PB-1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.09898	-118.29599	"PC FOR ""KAISER"" MEDICAL SPACE. SCOPE INCLUDES REMOVAL  OF EXISTING ""SCOPE WASHERS"" AND REPLACE WITH (4) NEW ""SCOPE WASHER"". INSTALLING NEW PANEL AND CIRCUITS.B#17016-10000-26706"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70593	11041-10003-19246	6701 N ETON AVE 1-298	91303	3	180B105    27	2148030035	(WC)C/I-60/1.0	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			02/05/2013 12:00:00 AM			PC Approved	02/05/2013 12:00:00 AM	ADDRESS	34.19217	-118.59564	REVISED SET OF PLANS. SUPPLEMENTAL TO 11041-10003-19246. FUTURE PV LOCATION CHANGED.   BREAKER AND FEEDER FOR LP1 HAS CHANGED**********************************************************Revised permitted set of plans- added outlets to existing circuits 2nd floor fitness room;in electrical a remove inverter subpanel and decreased inverter fromm 8KVA to 6KVA;subpanel is relocatedt to garage main electrical room and connect to panel supplied by inverter in that room. inverter is increased 10KVA  Changes to previosly approved sets, , changes to title 24, feders and interior lightings.   No new ckt or panels. Revise elevator 1, 2, and 3, remove load from existing panels and relocate receptacle and luminaires. EPC is for delta I only. 9-13-12   (((((((((((((((((NEW FIVE-STORY, TYPE-III-A, 298-UNIT APARTMENT WITH ATTACHED PKG GARAGE (Automatic fire srpinkler throughout for the story increase). See separate permit  for attached parking garage.Need to file a variance to separate the FA plans from the electrical plans.Plan check fees were determined by client.))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70594	18041-10000-05024	6450 N DENNY AVE	91606	2	180B177   197	2414033039	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.18818	-118.36473	New Tesla Battery installed in a single family residential, with existing PV system. Battery size 14kWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70595	19041-20000-00470	9400 N BURNET AVE #119	91343	7	198B145   103	2656021106	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2019 12:00:00 AM	01/04/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	PIN	34.2413442	-118.46253399	PV1.  Install 5.94 kW roof mounted grid tied PV system.  (18) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70596	18041-20001-25238	8250 W FOOTHILL BLVD	91040	7	204B193   151	2560009049	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1034.00	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM			PC Approved	09/25/2018 12:00:00 AM	ADDRESS	34.25945	-118.31307	Expedite per applicant requestPlan check for PV roof mounted system on commercial  Extra Space Storage, system size: 86.4kW AC with 288 modules and 6 inverters(14.4kW) Solaredge SE 14.4KUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70597	12041-20000-05176	4371 S GLENCOE AVE	90292	11	105B153    85	4212004023	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	08/08/2012 12:00:00 AM	ADDRESS	33.9857	-118.43834	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70598	19041-10000-29542	6326 W LINDENHURST AVE	90048	5	135B177   331	5510020029	R1-1-O-RFA	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.06612	-118.36579	[E-plan]  DELTA 2 Changes - Relocation of solar equipment (MSP, battery, AC disco, DC disco, storage system transformer, inverter, critical load panel) to south facing wall of the back of home. All revised pages have clouds.PV - 18041-90000-29872Battery - 19041-10000-00436Delta 1 changes  - 19041-10000-14141	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70599	16041-10001-13917	13160 W MINDANAO WAY 3RD FLR	90292	11	105B153    92	4212007007	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM			PC Approved	10/14/2016 12:00:00 AM	ADDRESS	33.98501	-118.43726	PC for energy only. Reduction of scope of work. Total area affected went from 16355 to 10070 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70600	15041-10000-31571	1 S LMU DR DES-324	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	33.96577	-118.42406	Power plan check for a  MEDIUM VOLTAGE of replacing a step down transformer (from 5kv to 208v) and a distribution board. All loads are reconnected; there is no additional new load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70601	13041-10000-12454	11635 W SHELDON ST	91352	6	201B169   103	2537023015	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/23/2013 12:00:00 AM	ADDRESS	34.24543	-118.38567	Title 24 and emergency lighting, for one story bldg, office	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70602	19041-10000-48838	1636 S STAUNTON AVE	90021	14	120A213   309	5167003029	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.02202	-118.24135	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70603	17041-10000-16689	20502 S DENKER AVE	90501	15	054B193   187	7351020008	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	06/07/2018 12:00:00 AM	ADDRESS	33.84474	-118.30377	PC FOR T24 ENERGY ONLY. 400A SERVICE UPGRADE. PROVIDING NEW SITE LIGHTING TO EXISTING PARKING LOT.PERMIT FOR ELECTRICAL WORK TO BE OBTAINED ON INSPECTION FEE PERIOD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70604	18041-20000-46702	15821 W VENTURA BLVD ste 235	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.15584	-118.47812	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for iundoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70605	16041-10000-35481	4760 W SUNSET BLVD	90027	13	147B197   733	5543015021	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Info Complete	10/17/2016 12:00:00 AM	ADDRESS	34.09788	-118.29343	PC for power only for an existing medical office on the 3rd floor. Scope includes new circuits for a new treatment room(General care area, non-invasive procedures) and office space. B16016-10000-23985	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70606	17041-20001-40184	16238 W RAYMER ST	91406	6	189B137    19	2205029037	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			11/07/2017 12:00:00 AM			PC Approved	11/21/2017 12:00:00 AM	ADDRESS	34.21771	-118.48681	expeditepv2install roof mounted pv system sized 90kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70607	17041-10000-33154	7400 W FOOTHILL BLVD	91042	7	202-5A197  47	2563008021	C2-1VL, R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	ADDRESS	34.2513	-118.29354	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 13200 SQ.FT (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70608	17041-10000-14948	9592 N TOPANGA CANYON BLVD	91311	12	201B101   490	2746018009	(Q)MR1-1, QMR1-1, [T][Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24425	-118.60651	PC for energy only, Removing HID fixtures and replacing them with new LED. Area: 14,700 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70609	13041-10001-31463	1236 W LEIGHTON AVE ste#3	90037	8	117B197  1164	5037003003	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.01307	-118.29858	Expedited RSES plan check per applicant request.(((PV1, Install 3 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US.  12 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70610	12041-20000-14400	420 N FAIRFAX AVE	90036	5	141B177  1385	5527030019	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			06/21/2012 12:00:00 AM			PC Approved	06/21/2012 12:00:00 AM	ADDRESS	34.07886	-118.36128	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-90000-13750	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70611	15041-20000-12921	11764 W IDAHO AVE 1-8	90025	11	126B149   575	4262013008	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Apartment			04/29/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	01/26/2016 12:00:00 AM	ADDRESS	34.0417	-118.4563	Plan check for a new fire alarm system. Building is a new 8-unit apartment building. Fire alarm consists of (1) FACP, and (59) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70612	17041-20000-18011	1888 CENTURY PARK EAST SUITE 1550	90067	5	132B161    13	4319001006	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	PIN	34.06160176	-118.41389445	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. 400 SQFT. SUITE 1550.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70613	12041-20000-30541	13455 W MAXELLA AVE 140	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/19/2012 12:00:00 AM	02/25/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	Plan check for power and energy. First time tenant. Le Pain Quotidien. Unit #140. 3217 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70614	16041-10000-20905	3715 W SAN MARINO ST 1-19	90019	4	132B189  1117	5092022033	R3-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			06/14/2016 12:00:00 AM			PC Info Complete	07/29/2016 12:00:00 AM	ADDRESS	34.05453	-118.31375	FIRE ALARM SYSTEM WITH 158 DEVICES AND 6 PANELS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70615	13041-10000-25777	1100 S LA CIENEGA BLVD UNIT 100	90035	5	132B173   732	5087002017	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Info Complete	10/08/2013 12:00:00 AM	ADDRESS	34.05679	-118.37597	PLAN CHECK FOR POWER AND ENERGY. CHANGE OF USE FROM OFFICE/RETAIL TO MEDICAL OFFICE. 1 STORY UNIT 100. PERMIT HAS ALREADY BEEN PULLED UNDER 13041-30000-20086.  EXISTING PANELS. 1536 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70616	18041-10000-31788	10250 W SANTA MONICA BLVD 2860	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Issued	09/13/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	PLAN CHECK FOR POWER AND ENERGY. TENANT CORE AND SHELL  IN SUITE # 2860 OF CENTURY CITY WESTFIELD MALL.3,174 SQR FT. BLDG PERMIT: 18016-10000-26053.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70617	14041-20000-08960	1453 S ALLENFORD AVE	90049	11	132B137   631	4407008010	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.05455	-118.49502	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING MICROINVERTER ENPHASE M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70618	11041-10000-20632	1130-1138 E LAKE ST BLDG 26	90291	11	111B145    36	4243001040	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.00391	-118.45905	LINCOLN PLAZA APARTMENT BUILDING PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70619	16041-20000-06883	1135 W 84TH ST	90044	8	097-5A197  34	6033015030	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	33.96284	-118.29522	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. System size: 3.8kW.Ungrounded system. Each module is connected to a 400W power optimizer. (13) 330W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70620	18041-20000-48864	22122 W VICTORY BLVD	91367	3	177B101     6	2146001023	R4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/27/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	34.1863	-118.60916	ti to an existing commercial building.  replacing all light fixtures in clubhouse and proshop.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70621	13041-10001-02119	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Info Complete	02/13/2013 12:00:00 AM	ADDRESS	33.9867	-118.44159	SUPPL. APP FOR CHANGES TO THE APPROVED PLANS. PLAN CHECK ONLY. THE PERMIT WAS ISSUED 13041-10000-02119 (PLAN CHECK FOR FIRE ALARM SYSTEM 1 PANELS AND 44 DEVICES.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70622	19041-10000-01395	203 S COLUMBIA PL	90026	13	133-5A207  68	5153016026	R3-1	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Expired	11/16/2023 12:00:00 AM	ADDRESS	34.06098	-118.26242	Plan check for a PV1 4.95 KW DC / 4.244 KW AC roofmountd system with (15) modules and micro inverter (IQ6 plus-72-2-US) interconnecting through a new load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70623	11041-10000-19954	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM			PC Approved	09/22/2011 12:00:00 AM	ADDRESS	34.22149	-118.43179	T.I. TO AN EXISTING OFFICE BUILDING.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.  (OPTHAMOLOGY, NORTH 2 MOB, 1ST FLOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70624	18041-10000-19563	1515 W 190TH ST 2nd Floor	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	33.85852	-118.30531	PC FOR INTERIOR REMODEL AT (E) OFFICE BUILDING.SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. IN (E) CORRIDORS AND ELEVATOR LOBBYTOTAL 1550 SQ.FT.   B#18016-20000-03931	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70625	17041-10000-08983	6601 W MELROSE AVE	90038	5	141B185   586	5524012027	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.0836	-118.33902	PC FOR ENERGY ONLY. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA 12725 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70626	14041-20000-21850	7327 N MILWOOD AVE	91303	3	186B105   759	2112024020	(T)(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Apartment			08/13/2014 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/14/2016 12:00:00 AM	ADDRESS	34.20364	-118.59454	Plan check for title 24 only on a new 2-story building including 9 units with 1 level garage. Plan check  total area 6336 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70627	19041-10000-46874	23526 W ELKWOOD ST	91304	12	189B093   549	2020006023	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM	12/23/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.2125	-118.63986	PV1, NEW ROOFTOP MOUNTED SYSTEM, SIZE IS 9.92 KWdc/7.6KWac. SCOPE OF WORK IS 32 MODULES (SNM310) WITH OPTIMZERS (SE P320). LEADING TO A CENTRAL INVERTER (SE 7600-US) WITH A BATTERY STORAGE SYSTEM (LG CHEM RESU10H). NO SERVICE PANEL UPGRADE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70628	12041-10000-16213	11805 W HENLEY LANE	90077	5	153B141    82	4377040024	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2012 12:00:00 AM	07/13/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	34.11644	-118.4742	New rooftop 6.24kw photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70629	17041-10000-42602	18601 W OXNARD ST	91356	3	177B125   667	2127018***	PF-1XL-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			11/27/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.18009	-118.53867	REPLACE INDOOR AND OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70630	17041-20001-10648	10431 N WOODLEY AVE	91344	12	207B141   845	2679009005	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM			PC Approved	04/20/2017 12:00:00 AM	ADDRESS	34.26022	-118.48503	expedite.pv1install roof mounted pv system sized 3kw interconnected with msp.this system is an addition to an existing system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70631	12041-20000-06027	151 N WESTERN AVE	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2114.10, 2115.00	Electrical	Electrical	Commercial			03/16/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.07445	-118.30931	change of use from retail to restaurantEnergy, emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70632	15041-20000-13076	6225 W CENTURY BLVD	90045	11	090B165     5	4124026005	C2-2, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Expired	06/19/2017 12:00:00 AM	ADDRESS	33.9457	-118.39456	Plan check for Replacing HVAC system for HYATT REGENCY  with total load connected to main switch board: 3,186A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70633	16041-20000-22506	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	10/21/2016 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.04403	-118.2199	"""$0 permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 132kW with 468 modules and 4 inverters(33.kW) connected to commercial BuildingNote: Applicant need to assign Building Name"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70634	18041-20000-25776	513 S CHICAGO ST	90033	14	126A221    71	5183019015	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.03988	-118.21555	PV1.  Install 6 kW roof mounted grid tied PV system.  (20) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70635	11041-10000-06921	1401 W PACIFIC COAST HWY	90744	15	036B201   726	7413023240	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	06/29/2011 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	ADDRESS	33.79088	-118.28336	New underground storage tank for an existing gas station. Epc is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70636	16041-10000-11949	316 E 2ND ST	90012	14	129A213    97	5161022002	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	07/25/2016 12:00:00 AM	ADDRESS	34.04885	-118.24135	"Change of use from Retail to Restaurant ""Poke Express"". Service size and other equipments remain the same, connected load less than 400A. PC for T-24 only, total area: 1,330 sq.ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70637	15041-10001-02113	12180 W MILLENNIUM EAST	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	Supplemental application for plan check only.  Changes to approved set.  Changes to fixture type and arrangement.*****Previous Work Description*****Plan check for Title 24 only. Project is the ground floor lobby (EAST). Total lighting area = 1,825 sq. ft. 2008 compliance forms have been used as the building permit was submitted before 7/1/2014. Plan check for power, outdoor lighting, and the rest of the indoor lighting is under application 14041-20000-06259.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70638	15041-20000-31621	846 N SIERRA BONITA AVE	90046	5	141B177    39	5526003016	R2-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Closed	08/02/2018 12:00:00 AM	ADDRESS	34.08667	-118.35415	Plan check for power and Title-24 (energy).  Total area = 5,250 sq. ft. (conditioned) + 3,470 sq. ft. (unconditioned) + 1,860 sq. ft. (hardscape).New electrical distribution system for new elderly care facility with 8 guest rooms (10 beds) and underground parking area.  Low-rise building with 600 A service and backup generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70639	17041-10000-18216	8714 N ETIWANDA AVE	91325	12	195B125   813	2769021036	R3-1, [Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.22919	-118.53218	PC FOR T24 ENERGY ONLY FOR REUSE OF EXISTING WAREHOUSE/ OFFICE. PROVIDING UPDATED LIGHTING AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70640	18041-20000-29304	20742 BUR OAK CIR	91326	12	219B109   360	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	PIN	34.29414492	-118.58745412	PV1.  Install 3.35 kW AC roof mounted grid tied PV system.  (10) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70641	17041-10001-17051	300 WORLD WAY SPACE 333	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM			PC Approved	08/31/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	"PC FOR REVISIONS TO APPROVED SET UNDER DELTA 7.SCOPE INCULDES CHANGE TO ""LF"" PANEL TO REFLECT FIELD INSTALLATION. THIS IS PLAN CHECK ONLY!!!TENANT IMPROVEMET FOR NEW BAR  WITH KITCHEN., new lighting. pc for t24 energy only."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70642	18041-20000-48361	21749 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	34.16856	-118.60199	Plan check for Title 24 only in existing restaurant Tenant Improvement rest room and corridor. Total area: 841 sq ft. B#18016-20000-28300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70643	11041-10000-15513	2706 W WILSHIRE BLVD	90057	1	133-5A201  94	5141011016	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			07/28/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	01/17/2014 12:00:00 AM	ADDRESS	34.06093	-118.28296	REMODEL OF EXISTING 2 STORY BUILDING FROM OFFICE SPACES TO A RESTAURANT. INCLUDING PARTIAL BASEMENT AND ROOF PARKING. NEW PARTITIONS, DEMO OF OLD, MEPIS, FLOORING, CEILINGS. NEW RESTROOMS, LIGHTING.  (SEE COMMENT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70644	12041-10000-13385	9124 S BROADWAY	90003	8	094-5A203 246	6040036014	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			06/08/2012 12:00:00 AM	06/08/2012 12:00:00 AM		Permit Finaled	07/03/2012 12:00:00 AM	ADDRESS	33.95303	-118.27797	Plan check for new fire alarm. 1 panel and 10 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70645	16041-20000-03238	11801 W SHELDON ST	91352	6	201B169   102	2537021903	[Q]PF-1XL, [Q]PF-1XL-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Expired	04/25/2018 12:00:00 AM	ADDRESS	34.24203	-118.39031	PV2. INSTALLION OF CENTRAL INVERTER SYSTEM  FOR SOLAR CANOPY.  SYSTEM SIZE: 350KW BUILDING PERMIT # 16010-20000-00027	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70646	17041-20000-45330	10412 N FULLBRIGHT AVE	91311	12	207B113   288	2707017025	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.25985	-118.57695	pv1install roof mounted pv system sized 11.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70647	16041-10001-10054	2108-2110 W SUNSET BLVD	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			10/06/2016 12:00:00 AM			PC Approved	10/06/2016 12:00:00 AM	PIN	34.07718395	-118.26405818	10/06/16Changes to an approved set of plans. All changes are cloued under delta 1. Changes include adding mezzanine lights. Note: Original application is under PCIS#16041-10000-10054(((((CREATING SHELL SPACE FOR FUTURE RESTAURANT. PC FOR T24 ENERGY ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70648	12041-20000-16951	9248 W SWALLOW DR	90069	5	150B169  1281	5561007004	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	34.10458	-118.3901	Roof mounted P.V. system with 20.9 KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70649	18041-10000-48429	2300 N FLETCHER DR	90039	13	150A209   212	5438015001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Issued	12/21/2018 12:00:00 AM	ADDRESS	34.1045	-118.25881	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70650	13041-10001-05747	380 WORLD WAY Space T64	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	changes to approved plans: shows more detail about the location of  partial fourth floor storage room electrical plan. also shows that kitchen table/counter actually includes a load center. PROPOSED 803 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Scoreboard LA).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70651	19041-10000-04868	10555 N CORBIN AVE	91326	12	207B117   290	2708010017	(T)(Q)RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Closed	01/05/2021 12:00:00 AM				Title 24 plan check.  Installation of private tract site lighting in new development (Tract No 53178).  Lighting area = 18665 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70652	18041-10002-19468	5563 W ADAMS BLVD	90016	10	123B177   969	5048001057	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM			PC Approved	01/31/2020 12:00:00 AM	ADDRESS	34.03264	-118.36417	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE REVISION OF SINGLE LINE DIAGRAM, REMOVAL OF LIGHT FIXTURES AND RELOCATION OF CIRCUITS. NOTE ALL CHANGES ON CLOUDED AREAS.___________________________________________________________________CONSTRUCTION OF A NEW TWO STORY COMMERCIAL BUILDING.FULL PLAN CHECK FOR POWER AND ENERGY.BLDG PERMIT # 18010-10000-01372	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70653	16041-10006-04795	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	03/05/2021 12:00:00 AM		Permit Finaled	03/12/2021 12:00:00 AM	ADDRESS	34.0631	-118.36086	change to an approved set. change under delta 43 only. adding 1-45kva transformr and 1-175amp panel. and changing the suppling switchboard of 2-50HP elevators.  B# 13014-10000-03762	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70654	15041-10000-01920	1660 W ANAHEIM ST	90731	15	030B201   315	7412022010	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Issued	05/20/2015 12:00:00 AM	ADDRESS	33.77884	-118.29327	Installation of additional motors for fluid catalytic cracking unit.  New lighting and receptacle for vessels.  New fan circuit for additional transformer ventilation.  Class I Divisions I and II hazardous area classifications.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70655	13041-10000-10071	931-933 N HIGHLAND AVE	90038	4	144B185  1094	5532012038	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.08802	-118.33877	POWER AND ENERGY PLAN CHECK FOR CHANGE OF USE FROM FILM PROCESSING SCHOOL (TUTORING CENTER) AND GYM. PLAN CHECK FOR TWO SEPARATE BUILDINGS. NEW 400A SERVICE FOR PARCEL 2 BUILDING. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED. PARCEL 3 BUILDING PERMIT UNDER #13041-10000-13678	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70656	15041-20000-21646	2111 N CAHUENGA BLVD BLDG 1	90068	4	151-5A187 288	5576003043	R3-1	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	Apartment			09/11/2015 12:00:00 AM	07/28/2016 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.1091	-118.33132	Plan check for new 9 units Townhome 600A Service Building 1. No commom area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70657	16041-10001-09578	4910 N DUNMAN AVE	91364	3	168B097   165	2074006016	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.15931	-118.62679	05/11/16Note: permit and PC fees are $0 due to senate bill 1222.  Changes to an approved set of plans. Change include adding 6 modules to the PV roof-layout. System size on the AC side still remains 10kw. Note: Original permit paid under PCIS#16041-10000-09578 (((((PV1, rooftop solar installation   10kW system      (40) CS6P-255P        (1) SE10000A-US        P300 is used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70658	16041-20000-29228	13358 W CHANDLER BLVD	91401	4	171B157   148	2344018035	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	34.16818	-118.42455	FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.Plan check for a PV1 roof-mounted PV system. System size is 13.8 kWac and consists of (55) modules, (55) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70659	14041-10000-06665	10635 W SANTA MONICA BLVD 2ND FLOOR	90024	5	129B157    42	4326034028	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2656.01	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	PIN	34.05365874	-118.43036269	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES ON 2ND FLOOR. NO CHANGE IN OCCUPANCY, <400 AMPS NEWLY CONNECTED LOAD. 1061 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70660	15041-10001-17696	18711 W SHERMAN WAY	91335	3	183B121   100	2118026019	[Q]C2-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM			PC Approved	07/05/2016 12:00:00 AM	ADDRESS	34.20128	-118.54074	REVISIONS TO PERMITTED SET OF PLANS: EXCEPT FOR THE ELEVATOR FEEDERS, OTHER  FEEDERS ARE CHANGED FROM CU TO AL. {{{{{{{{{FULL PLAN CHECK TO A NEW 30 UNIT( 5 TYPICAL) 4-STORY MULTI-RESIDENTIAL BUILDING. PC FOR ENERGY AND POWER. 1200 AMP SERVICE, TOTAL SQ. FT. 22629.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70661	19041-10000-30728	11795 W OLYMPIC BLVD	90064	11	123B149   458	4260010020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.03357	-118.44964	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING WALGREENS T.I IN EXAM ROOMS. SCOPE INCLUDES ADDING NEW LOADS AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70662	14041-10000-11419	400 WORLD WAY TERMINAL 4	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/30/2014 12:00:00 AM			Reviewed by Supervisor	05/16/2014 12:00:00 AM	ADDRESS	33.94221	-118.40701	TEMPORARY POWER FOR LAX TERMINAL 4	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70663	10041-10000-24650	440 S VERMONT AVE #106 & 107	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	1st time tenant in spaces 106 and 107 combined into one space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70664	19041-10000-44379	590 N VERMONT AVE 2nd Flr-Rm 618	90004	13	141B197   776	5539033010	C2-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	04/04/2023 12:00:00 AM	ADDRESS	34.08157	-118.2915	Energy plan check only. Area of scope (2,415)SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70665	12041-10000-29714	5055 W JEFFERSON BLVD	90016	10	120B177   722	5049034021	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			12/10/2012 12:00:00 AM			PC Approved	12/10/2012 12:00:00 AM	ADDRESS	34.02565	-118.35393	Plan check T24 Energy for existing single story woodwork shop fire damage repair.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70666	13041-20000-35408	3502 S TROUSDALE PKWY	90089	9	120A201    75	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.02175	-118.28408	PC FOR T24 ENERGY ONLY. TOTAL AREA 835 SQ FT REMODEL 3 RESTROOMS. NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70667	10041-10000-21866	1700 E CESAR E CHAVEZ AVE # 1800	90033	14	130-5A221 257	5174008024	C2-1, [Q]R5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2035.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	03/01/2011 12:00:00 AM		Permit Finaled	06/01/2011 12:00:00 AM	ADDRESS	34.05093	-118.21753	ALTERATIONS OF EXISTING WOMEN'S IMAGING CENTER SUITE ON NORTHWEST PORTION OF FIRST FLOOR OF EXISTING 3-STORY BUILDING.  WORK INCLUDES, BUT NOT LIMITED TO, REMODEL OF SUITE FOR USE OF MAMMOGRAPHY, ULTRASOUND EQUIPMENT IN WOMEN'S CENTER...(see additional comments) SUBMITTED PER APPLICANT DIRECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70668	15041-10000-11676	3007 S LA SALLE AVE	90018	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			04/20/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	04/13/2016 12:00:00 AM	ADDRESS	34.02701	-118.30549	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 4.2 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70669	10041-10000-09764	4500 W PICO BLVD	90019	10	129B185  1040	5083032002	C4-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM	08/20/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.04828	-118.33371	New service at existing buildng to supply new and existing panels at cell site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70670	15041-10000-16514	6411 W IMPERIAL HWY	90045	11	087B165    12	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Closed	01/23/2018 12:00:00 AM	ADDRESS	33.93238	-118.3989	New fire alarm system for a single story commercial building with (1) fire alarm panel, (2) power supplies and (45) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70671	12041-20000-15707	17461 W VENTURA BLVD	91316	5	171B129   410	2257016054	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	07/27/2012 12:00:00 AM		Permit Finaled	11/15/2012 12:00:00 AM	ADDRESS	34.16157	-118.51326	energy plan check market	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70672	10041-20000-00452	6736 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			01/11/2010 12:00:00 AM	01/11/2010 12:00:00 AM		Permit Finaled	04/07/2010 12:00:00 AM	ADDRESS	34.11833	-118.34034	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70673	17041-10000-06990	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	PC FOR ENERGY ONLY. OFFICE  TENANT IMPROVEMENT AT LEVEL 5.  Qatar Air.AREA: 940 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70674	13041-10000-33686	807 E 12TH ST STE 105	90021	14	123A211    42	5132009013	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			PC Approved	12/04/2013 12:00:00 AM	ADDRESS	34.03247	-118.25043	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING; REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 312 SQ FT. REPLACING 2 TOTAL UNITS. ALL WORK IS FOR INTERIOR RENOVATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70675	13041-20000-18184	1216 W HILL DR	90041	14	163-5A229 280	5691015004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.14085	-118.1907	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.6 KW. USING TOTAL OF 19 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70676	15041-10000-23973	1019 S ALBANY ST 1-20	90015	1	129A205   249	5137013016	R4-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Apartment			07/27/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Expired	08/29/2017 12:00:00 AM	ADDRESS	34.04738	-118.27166	IN HALLWAYS AND EGRESS PATHS IN AN EXISTING APT BUILDING, REPLACING EXIT SIGNS WITH EXIT SIGNS WITH 90-MINUTE EMERGENCY BATTERY PACKS per F.Y	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70677	19041-10000-21332	259 S BROADWAY	90012	14	130-5A211  66	5149009002	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	07/23/2020 12:00:00 AM	ADDRESS	34.0512	-118.24812	T-24 PLAN CHECK FOR AN INTERIOR TI OF T-MOBILE RETAIL STORE. SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1827 SQ.FT.TOTAL CONNECTED LOAD IS LESS THAN 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70678	16041-20000-14598	3945 W INGRAHAM ST	90005	10	132B193   121	5092030022	R4P-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Apartment			04/26/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.06079	-118.31283	Plan check for power and energy. Project site is a new 14-unit, 5-story apartment building with a basement garage. Work includes a 1,600-amp service, distribution boards and associated loads. Total lighting area = 18,220 sq. ft.Note: Building application has been generated under 16010-20000-01650	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70679	10041-10001-14399	5779 W WILSHIRE BLVD	90036	4	135B177   470	5508015004	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM			PC Approved	11/10/2010 12:00:00 AM	ADDRESS	34.06261	-118.35433	DELTA 7 REVISIONS TO APPROVED SET OF PLANST.I. to existing restuarant.  Install general/emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70680	11041-20000-26620	11085 W HERSHEY ST	91352	2	201B173    88	2538026024	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2011 12:00:00 AM	02/15/2012 12:00:00 AM		Permit Finaled	04/20/2012 12:00:00 AM	ADDRESS	34.2507	-118.37295	New 1.38 KW roof mounted PV system for a single family residence.  Applicant is using the M215 microinverter.  A variance has been filed to use the microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70681	14041-10000-31079	8472 W MELROSE PL	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	06/13/2016 12:00:00 AM	ADDRESS	34.0834	-118.37568	Plan check for power and energy. New 800 A service upgrade for a 2-story building (office space). Total indoor lighting area = 1,360 sq. ft. Total outdoor lighting area = 800 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70682	16041-10000-21012	4725 N RADFORD AVE	91607	2	168B169   645	2355014041		South Valley				1433.00	Electrical	Electrical	Apartment			06/15/2016 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.15663	-118.39239	FULL PC FOR POWER AND ENERGY FOR A NEW 4-STORY TYPE V-A, 21 UNIT APARTMENT BLDG OVER TWO LEVELS TYPE 1A SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES A NEW 800A 120/208V 3PH 4 WIRE SERVICE (5 DIFFERENT TYPES OF UNITS). TOTAL AFFECTED AREA IS 27123 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70683	17041-20001-21088	10047 N RUDNICK AVE	91311	12	204B101   497	2745007061	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2017 12:00:00 AM			PC Approved	07/03/2017 12:00:00 AM	ADDRESS	34.25307	-118.61281	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.2.88kW ungrounded system.(12) EnPhase M250 microinverters.(12) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70684	18041-10000-07484	5555 N VAN NUYS BLVD	91401	4	174B149   908	2249001018	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.1719	-118.44909	PC for T24 only for replacement of indoor-outdoor existing fixtures with LED fixtures for Chase bank. Total area Indoor  is 15380sqft.Plan checker to verify address	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70685	18041-20000-25860	699 W EXPOSITION BLVD 2nd-3rd Floors	90089	9	118-5A201  23	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	04/30/2021 12:00:00 AM	ADDRESS	34.01842	-118.28508	Plan check for Title 24 only. Project site is the 2nd and 3rd floor of an existing commercial building. Project scope is a tenant impovement. Total lighting area = 4,494 sq. ft.Note: Building applications have been generated under 18016-10000-19844/18936	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70686	19041-10000-45607	1816 E OLYMPIC BLVD	90021	14	121-5A215  72	5166026012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM			PC Info Complete	12/18/2019 12:00:00 AM	ADDRESS	34.02724	-118.23839	T-24 ENERGY PLAN CHECK. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 16859 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70687	14041-20001-11921	6507 N BLUCHER AVE	91406	6	180B141   640	2234011014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.18881	-118.47297	(((EXPEDITE FEES)))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC WITH OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70688	19041-20000-44822	3485 S SAWTELLE BLVD	90066	11	117B157   389	4249026027	R3-1, [Q]R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.01702	-118.42433	Plan check for Title 24 energy only new lighting control. Total area: 7098 sq ft. Installed load less than 400A. Note: reuse existing service to the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70689	18041-20000-18799	2000 N HIGHLAND AVE	90068	4	150A185   111	5575024011	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			05/21/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Issued	07/18/2018 12:00:00 AM	ADDRESS	34.10679	-118.33728	Service upgrade for (E) 2-story apartment building - (N) 600A 240/120V 1ph-3w service.  Plan check for power.  Dwelling unit loads unchanged.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70690	18041-10000-08611	1119 E 8TH ST	90021	14	124-5A213 330	5146003054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.03514	-118.24489	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 10250 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70691	16041-10000-30600	301 S LAS PALMAS AVE	90020	4	135B185   110	5507002017	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/21/2019 12:00:00 AM	ADDRESS	34.06855	-118.33587	PC FOR SERVICE UPGRADE TO 600A WITH METHANE PULL SECTION. VOLTAGE CLASS STILL 120/240 1 PHASE. PROVIDE NEW 600 WITH NEW SUBPANELS. RECONNECTING MOST EXISTING EQUIPMENT AND PROVIDE SOME NEW INTERIOR EQUIPMENT. PC FOR POWER SYSTEM ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70692	19041-20001-01327	7643 N SHADYGLADE AVE	91605	2	186B165    86	2307005020	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM			PC Approved	02/22/2019 12:00:00 AM	ADDRESS	34.20994	-118.40267	02/22/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta C and D. Inverter model has changed. Inverter now being used integrated EV charger.*****Original Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 9.57 kWdc/8.79 kWac-CEC and consists of (1) 7.6 kWac rated inverter and (29) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70693	18041-10001-03666	11846 N WOOD RANCH ROAD	91344	12	216B129   272	2601066001	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	34.28687	-118.52026	**Expedited fee per applicantInstall New PV1 rooftop solar on (E) SFD, system size 15.2kW AC/ 18.85 kW DC. (2) 7.6 kW central inverters, (58) modules with (58) power optimizers, and (1) load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70694	14041-20001-23039	4027 N ROCK HAMPTON DR	91356	3	165B125   474	2184054011	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.14443	-118.53689	expedite feespv1 single family. total system size 11kw AC using 2 central transformerless inverters. using total of 50 modules. nonstandard plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70695	19041-20001-35746	23251 W KESWICK ST	91304	12	189B093   739	2027037005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2019 12:00:00 AM			PC Approved	09/27/2019 12:00:00 AM	ADDRESS	34.21033	-118.63408	Expedited plan checking fee.PV1.  Install 12.285 kW roof mounted grid tied PV system and 27 kWh energy storage system.  (39) modules with 11.4 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70696	16041-20003-31733	269 S SAN PEDRO ST	90012	14	129A213   450	5161025***	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	05/26/2017 12:00:00 AM	ADDRESS	34.0477	-118.2427	5.26.2017 - Plan check for modification to approved set. Change emergency lighting backup power from internal battery to existing external generator. Update lighting fixture schedule, home-runs on floor plan, and panel schedules to reflect change. Changes clouded delta 2.======PC FOR CHANGES TO APPROVED SET. EXRAY MACHINE AND TRANSFORMER ARE NEW TO SCOPE. PC AND PERMIT FOR ADDITIONAL SCOPE OF WORK. DELTA 1 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70697	16041-30000-15843	444 S FLOWER ST Suite 1550	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	01/26/2017 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to a portion of the 15th floor. Total lighting area = 6,345 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70698	17041-20000-09174	21785 W VENTURA BLVD	91364	3	174B105    57	2168027025	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.16857	-118.60243	PLANCHECK FOR T24 ENERGY. TI TO RETAIL SPACE.  COMBINING 2 TENANT SPACES AND EXPAND BEAUTY SALON. 1997 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70699	12041-10000-05431	972-980 E ELKLAND PL	90291	11	111B145   913	4243002066	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			03/09/2012 12:00:00 AM	03/09/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.99903	-118.45916	Two story apartment, new fire alarm, lincoln place,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70700	13041-10000-02155	755 S COCHRAN AVE	90036	4	132B181   197	5089003032	R3-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			01/28/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	10/08/2013 12:00:00 AM	ADDRESS	34.06081	-118.34781	PERMIT TO BE ISSUED BY ELECTRICAL PLAN CHECK STAFF ONLY.PLAN CHECK FOR TITLE 24 CLASSROOMS. T.I. (2,875 sqft)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70701	18041-20000-12301	14632 W GLENRIDGE CT	91342	7	219B149   884	2507009***	(Q)RD3-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.29422	-118.45026	PC for 3.8kW(ac) / 3.85kW(dc) rooftop solar for SFD.  Installing 11 modules with optimizers, central inveter and connecting to existing center fed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70702	16041-20000-40682	15816 W LEADWELL ST	91406	6	186B141   869	2206037102	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	PIN	34.20365596	-118.47775758	Plan check for the installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP.10.08kW ungrounded system. (28) 360W ac modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70703	13041-10000-05594	731 S OGDEN DR	90036	4	135B177   541	5086010031	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Closed	03/21/2014 12:00:00 AM	ADDRESS	34.06179	-118.36001	Service previously approved under 12041-10000-18827 without power equipment.  New 400 A service and power equipment to be used in methane zone for the purpose of an exploratory Metro shaft.construct a temporary xploratory shaft for westside subweay extension project. excavation and structural support of an shaft and staff support to assist metro to do tests. 9 months observation period then backfill shaft. 2 prefab trailers, generator, gas detection, exhaust fans, emg lights, sump pumps	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70704	16041-10000-42549	8729 N CORBIN AVE	91324	12	195B117   179	2782022006	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2016 12:00:00 AM			Corrections Issued	12/05/2016 12:00:00 AM	ADDRESS	34.22902	-118.56247	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.0KWac.(32)MODULES-SOLARWORLD SW290(32)MICROINVERTERS-ENPHASE M250-60-2LL-S22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70705	15041-10000-09111	4086 S DEL REY AVE	90292	11	108B153  1186	4230005001	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM			PC Info Complete	04/14/2015 12:00:00 AM	ADDRESS	33.9888	-118.44521	PC FOR POWER. NEW 800 A SERVICE, TO FEED TO EXISITING PANELS. AVARIANCE HAS BEEEN FILED FOR THE LETTHROUGH FUSES. . ELECTRIC WORK UNDER 4082 DEL REY UNDER SEPARATE APPLICATIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70706	14041-10000-11714	3811 S BUCKINGHAM ROAD	90008	10	117B181   379	5045005009	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.0169	-118.34054	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM USING STANDARD PLAN. TOTAL SYSTEM SIZE 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70707	14041-20000-14411	18564 S WESTERN AVE	90248	15	060B193   210	6108001055	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	33.86223	-118.30895	Addition to existing car dealership.  Connection of 2 existing buildings and new service/distribution equipment.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70708	15041-10000-28183	10601 W WASHINGTON BLVD 1-135	90232	5	117B165   262	4208009049	(T)(Q)RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			08/31/2015 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	11/17/2018 12:00:00 AM	ADDRESS	34.0175	-118.40491	FULL PC FOR POWER AND ENERGY ON A NEW 5 STORY BUILDING(MIXED USE BUILDING) . 3 LEVELS BELOW GRADE AND 2 LEVELS ABOVE GRADE. FEES PER APPLICANT. FIRE ALARM VARIANCE TO BE FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70709	19041-20000-40102	5827 N SERRANIA AVE	91367	3	174B109    48	2149018008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	PIN	34.17686297	-118.58862004	PV1. INSTALL 3.48 KW DC / 3.8 KW AC PV SYSTEM WITH (12) MODULES/OPTIMIZERS, (1) INVERTER (SE3800), AND 9.8 KWH ENERGY STORAGE SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70710	17041-10001-15913	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM			PC Info Complete	08/21/2019 12:00:00 AM	ADDRESS	34.06664	-118.46903	CHANGES TO AN APPROVED SET. CHANGING TEMPORARY POWER TO PERMANENT POWER. ALL EQUIPMENT TO REMAIN. SERVICE SIZE IS 1200A WITH 225KVA TRANSFORMER.  Original Scope: ((PC FOR POWER FOR TEMPORARY POWER TO NEW SCHOOL BUILDING.TEMPORARY SERVICE PROVIDED BY DWP FOR 1200A DISTRIBUTION BOARD. SCOPE INCLUDES FEEDING EXISTING DISTRIBUTION EQUIPMENT AND ASSOCIATED WIRING. ALSO FEEDING CONSTRUCTION PANEL (LOADS ON CONSTRUCTION PANEL ARE NOT PART OF THE SCOPE OF THIS PROJECT)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70711	11041-10000-25146	130 S POINSETTIA PL	90036	5	138B181  1000	5512021027	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2011 12:00:00 AM	01/13/2012 12:00:00 AM		Permit Finaled	03/23/2012 12:00:00 AM	ADDRESS	34.07262	-118.34849	PV system <<<<<9.5KW, rooftop for a single family residnece with two inverters>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70712	15041-10000-10694	444 S SAN VICENTE BLVD 11TH FLR	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM			PC Info Complete	07/20/2015 12:00:00 AM	ADDRESS	34.07021	-118.37547	COMPLETE RENEVATION OF THE 11TH FLOOR OF A MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70713	17041-10000-33527	4353 S FIGUEROA ST	90037	9	112-5A201  16	5019010032	C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.00427	-118.28299	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70714	19041-20001-43152	13016 W GOLETA ST	91331	7	204B161   308	2623015006	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.2558	-118.41611	SUPPLEMENTAL TO ONLINE PERMIT 19041-90000-43152PV1. INSTALL 8.36 KW DC PV SYSTEM WITH (22) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600H).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70715	17041-10000-34441	1600 N VIEWMONT DR	90069	4	148-5A173 411	5558017024	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Expired	11/01/2023 12:00:00 AM	ADDRESS	34.10018	-118.37913	PC FOR PV SYSTEM WITH BATTERY STORAGE. PV SIZE 6.6KW AC USING 22 MODUES IN TOTAL. STORAGE UNIT TESLA POWERWALL 5.8KW WITH 13.5KWH STORAGE.Fees $0 due to SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70716	12041-10000-01906	500 W WORLD WAY 5L	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Approved	03/20/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. to an existing retail space.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70717	14041-20000-06019	10100 W TUJUNGA CANYON BLVD	91042	7	202-5A201 211	2568006028	R3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.25019	-118.28612	PV1 ROOF MOUNTED MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 1.3KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70718	19041-10000-41490	19929 W RINALDI ST	91326	12	213B113   302	2701040036	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.27592	-118.56887	"TI IN AN EXISTING ""BREAK ROOM"" OF ""BEST BUY"". INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA 433 SFT.Building Permit: 19016-10000-32696"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70719	19041-30000-31500	9416 W SIERRA MAR PL	90069	4	147B165   507	4392003017	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Issued	10/16/2019 12:00:00 AM	ADDRESS	34.09635	-118.39499	600 AMP 120/240 V 1 PHASE NEW SERVICE. SCOPE OF WORK INCLUDES PANELS AND EQUIPMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70720	13041-10001-24735	2508 1/2 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM			PC Approved	03/03/2014 12:00:00 AM	ADDRESS	34.0334	-118.2974	Expedited plan check for PV1 rooftop solar per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70721	14041-20002-11253	1933 S BUNDY DR	90025	11	123B149   366	4259019010	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	02/20/2015 12:00:00 AM	ADDRESS	34.0344	-118.45642	(2/20/2015) changes to an approved set of plans.  changes marked delta delta 8 on the plans.TI in (E) commercial office space in single story building.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70722	12041-20000-26176	5420 N MORELLA AVE	91607	2	174B169  1272	2348007036	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	34.16928	-118.38982	New 6kw Enphase microinver photovoltaic system for an existing single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70723	18041-10000-03456	14459 W TYLER ST	91342	7	225B149   160	2504004016	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/02/2018 12:00:00 AM	ADDRESS	34.31511	-118.44808	PV1 ROOF MOUNTED SOLAR SYSTEM USING AC MODULES. (35) AC MODULES AND A NEW LOAD CENTER. TOTAL SYSTEM SIZE 12.075KAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70724	19041-10000-53714	1750 W CENTURY BLVD	90047	8	091-5A193  72	6059001034	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	01/12/2021 12:00:00 AM	ADDRESS	33.9453	-118.30824	PC FOR A NEW FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES INSTALLATION OF 32 DEVICES, 1 FIRE ALARM PANEL & 1 CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70725	18041-10000-03144	800 S HARVARD BLVD	90005	10	132B193   640	5093022011	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.20	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	02/09/2021 12:00:00 AM	ADDRESS	34.05747	-118.30403	Full plan check for a new 6-story mixed-use (131 units with retail) with (2) subterranean parking garage. Scope includes a 4000-Amp Pull box with 3-phase 120/208V. Total (46) typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70726	14041-20000-33172	13362 N GLADSTONE AVE	91342	7	225B153   237	2510021027	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.31467	-118.43299	PV1PInstall a roof-mounted solar array on a SFD. Interconnect with 200A MSP (upgraded from 100A MSP).System size: 12kW (6+6). Ungrounded system.36 327W pv modules across 6 strings (inv1 - 6+6+6; inv2 - 7+6+5).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70727	18041-10000-34135	905 E 52ND ST	90011	9	108B209    44	5103029900	R2-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2292.00	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	33.99591	-118.25969	NEW FIRE ALARM SYSTEM WITH 22 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70728	14041-20000-24840	7006 S HOOVER ST UNIT 3	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW INTERCONNECTED WITH MSP FOR UNIT #3.ENPHASE M250 MICROINVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70729	17041-20000-01562	6862 N HAYVENHURST AVE	91406	6	183B137   380	2224019016	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	02/28/2018 12:00:00 AM	ADDRESS	34.19561	-118.49221	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 83.79 KW.( 266) HANWHA l-g5 315 MODULES(3) sma ST 30000TLNote: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70730	14041-10000-30207	4645 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.04717	-118.3388	Fire alarm system for a single commercial building; first floor and underground level; total (40) fire alarm devices, (1) fire alarm panel and (1) power supply.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70731	12041-10000-23634	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM	01/17/2013 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	Ti in a retail store. Space# 230. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70732	19041-20000-04662	440 S SEATON ST	90013	14	127-5A215 363	5163025010	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	09/06/2023 12:00:00 AM	ADDRESS	34.0421	-118.23734	ti to an existing commercial building.  adding new lighting new controls to corridors and staircases only.  plan check for energy and em lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70733	16041-10000-20651	723 W 53RD ST	90037	9	108B201   358	5001027021	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2016 12:00:00 AM	06/13/2016 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	ADDRESS	33.99429	-118.28627	PV1 INSTALL NEW 3.71 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(14) MODULES: CANADIAN SOLAR CS6P-265W(1) INVERTER: FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70734	15041-10000-19110	575 S BARRINGTON AVE	90049	11	132B145   207	4401011***	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			06/18/2015 12:00:00 AM	06/18/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.05769	-118.46827	UPGRADING ONE FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70735	14041-20000-14165	9350 N ETON AVE	91311	12	198B105    64	2746010016	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.24087	-118.59542	Convert portion of existing Manufacturing space (3684 sq. ft.) to office space.  Install general and emergency lighting.  Plan check for energy only.Note: Permit is under 14041-20000-14170	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70736	14041-20000-20743	22458 W VENTURA BLVD	91364	3	171B101   218	2040034010	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Commercial			07/31/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.16795	-118.61638	plan check for title 24 on an existing restaurant with 2264 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70737	16041-10001-45750	4939 E YORK BLVD	90042	14	156A225   225	5476017019	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM			PC Info Complete	12/14/2017 12:00:00 AM	ADDRESS	34.12175	-118.20762	Changes to an approved set of plan. Changes include upgrading service from 400A to 600A. Also updated lighting floor plan and T24 {Title 24 original plan check refer to 16041-20000-45750}Note: Permit fees are paid under the master application, PCIS#16041-20000-45750	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70738	19041-20000-31932	1718 N SAN REMO DR	90272	11	135B133   168	4432007021	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	10/15/2021 12:00:00 AM	ADDRESS	34.06368	-118.50017	PV1.  Install 18.91 kW DC roof mounted PV system.  (61) modules with (2) 7.7 kW rated inverters interconnected to (E) 600A 240/120V 1ph-3w service.$0 permit fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70739	15041-20000-17025	14033 W RIVERSIDE DR	91423	4	168B153   421	2269018080	[Q]RD1.5-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			06/03/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.15777	-118.43867	Plan check for Title 24 only. Project site is a new 2-story, 5-unit apartment building. Project scope is indoor and outdoor lighting. Total lighting area = 3,915 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70740	16041-10000-16428	1553 S ARLINGTON AVE	90019	10	126B189   216	5072034027	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Apartment			05/10/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.04402	-118.31799	NEW FIRE ALARM SYSTEM FOR A NEW 4-STORY, 46 UNITS APARTMENT BUILDING. 1 FA DEVICES, 2 COMMUNICATION PANEL. 114 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70741	09041-10014-24270	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM			PC Approved	08/28/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Revisions of electrical plans (autofiles) for the north  and south concourses at BRADLEY WEST GATES ; ADDITIONAL CIRCUITS FOR drinking fountains,elevator hoistway lighting, and at the MOV chiller yard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70742	14041-20001-27553	10330 N ALDEA AVE	91344	12	204B133   124	2695017006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.25859	-118.50867	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 8.8kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(41) SolarEdge P300 power optimizers(41) Kyocera KD255GX-LFB3 pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70743	14041-20001-13641	12675 N HUNNEWELL AVE	91342	7	219B161    70	2525002027	RS-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	05/23/2014 12:00:00 AM	ADDRESS	34.30055	-118.4191	reduce number of modules to 14. this is plan check only to changes to plan. 14 modules total$0 plan check fee due to senate bill 12222 from 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70744	19041-10000-38673	8490 W BEVERLY BLVD	90048	5	138B173   496	5511013070	[T][Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Info Complete	10/17/2019 12:00:00 AM	ADDRESS	34.07577	-118.37621	T-24 PLAN CHECK. TOTAL AFFECTED AREA IS 18000 SQ.FT. NEW LIGHTING FIXTURES ADDED TO EXISTING LIGHTING PLAN. EMERGENCY LIGHTING AND EXISTING CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70745	18041-20000-37315	20661 W BEECH CIR #324	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.29284	-118.58443	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70746	17041-20000-08653	12355 W MONTAGUE ST	91331	7	204B165   212	2537005017	M2-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.25413	-118.4026	Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 2,000-amp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70747	12041-10000-13171	16952 W BLANCHE PL	91344	12	219B133   513	2609026025	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2012 12:00:00 AM	06/07/2012 12:00:00 AM		Permit Finaled	09/26/2012 12:00:00 AM	ADDRESS	34.2955	-118.50128	New 11.04kw rooftop mounted PV system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70748	14041-20001-27590	1647 W TEMPLE ST 1-49	90026	13	136-5A207 119	5159023017	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Apartment			10/06/2014 12:00:00 AM			PC Approved	10/22/2014 12:00:00 AM	ADDRESS	34.06861	-118.26247	Expedited plan check fee per applicant. PV2.  Install 95.1 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70749	13041-20000-28891	4811 N ADELE CT	91364	3	168B113   219	2175026027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	10/31/2013 12:00:00 AM	ADDRESS	34.15768	-118.57172	PV1 TRANSFORMERLESS SYSTEM. USING SOLAR OPTIMIZERS. TOTAL SYSYEM SIZE 5.1 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70750	17041-10000-44169	20935 W FRANCINE LANE	91311	12	207B109   697	2706017041	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.26251	-118.59002	PC for rooftop solar for new 5kW system for SFD. Installing 23 JKM285M PV modules and one solaredge central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70751	13041-10000-08592	5067 N SAN FERNANDO ROAD WEST BLDG B-1	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.14396	-118.27105	RENOVATION OF CORRIDOR IN EXISTING LAB. WORK DONE IS BATHROOM AND CANOPY LIGHTING. T24 PC ONLY FOR ENERGY COMPLIANCE. PERMIT TO BE ISSUED FROM PC STAFF ONLY. TOTAL AREA 485 OUTDOOR AND 586 INDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70752	14041-10000-13318	901 S FLOWER ST	90015	14	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.04579	-118.26176	TI FOR EXISTING CONDO IN LOBBY AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70753	11041-10000-10859	6725 W SUNSET BLVD	90028	13	147A185    36	5547020044	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	07/25/2011 12:00:00 AM	ADDRESS	34.09814	-118.33717	TI TO AN EXISTING 5-STORY OFFICE BUILDING.  T-24 WITH EMERGENCY, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70754	13041-10000-15238	1505 S PERRINO PL BLDG A	90023	14	118-5A219  10	5169015014	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	09/27/2013 12:00:00 AM		Issued	09/27/2013 12:00:00 AM	ADDRESS	34.02018	-118.22248	PV2 COMMERCIAL ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 134.52 KW DC CONSTISTING OF 456 MODULES AND TWO INVERTERS. SINGLE STORY BUILDING A. [MODULES: S-ENERGY # SM-295PC8 |||| INVERTERS: SOLECTRIA # PVI-50KW AND SOLECTRIA # PVI-85KW]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70755	18041-10000-45658	1525 S LA CIENEGA BLVD	90035	5	129B173   739	4303031039	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.04977	-118.37633	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70756	17041-20000-22453	10620 W MAGNOLIA BLVD	91601	2	171B177   673	2419016016	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.16471	-118.36234	PLANCHECK FOR T24 ENERGY. INTERIOR REMODEL & ADD NEW SKYLIGHTS WITHIN EXIST RETAIL SPACE. 1872 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70757	10041-10000-03942	13075 S KIYOT WAY	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2010 12:00:00 AM			Reviewed by Supervisor	03/22/2010 12:00:00 AM	PIN	33.97159161	-118.42340103	Methane mitigation Level III for SFD  at Playa Vista	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70758	14041-10000-30779	5110 S CRENSHAW BLVD 1-32	90043	8	111B185   573	5013019035	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	Apartment			11/12/2014 12:00:00 AM			Reviewed by Supervisor	01/09/2015 12:00:00 AM	ADDRESS	33.99629	-118.33046	Installation of new fire alarm system for a new 32 unit apartment building.  161 devices + 1 control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70759	18041-10000-08048	9260 N OWENSMOUTH AVE	91311	12	198B105   107	2746011005	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.23872	-118.6017	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 12650 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70760	14041-10000-35251	9186 N INDEPENDENCE AVE	91311	12	198B105   126	2746009014	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.23807	-118.59165	Title 24 plan check only.  Total area = 2,912 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70761	17041-20000-33681	3415 S SEPULVEDA BLVD LOBBY	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	02/20/2018 12:00:00 AM	ADDRESS	34.02055	-118.42347	RENOVATION OF GROUND FLOOR LOBBY AND RESTROOM.  PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70762	17041-10000-33705	761 S BROADWAY	90014	14	127-5A209 103	5144014027	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Closed	04/07/2021 12:00:00 AM	ADDRESS	34.04399	-118.25475	PC for power and energy for core and shell for existing historic 10 story building.Installing new 1000A service, new distribution boards, 150kW generator, 75HP fire pump,equipment and circuits. Total of 481472 sqft.Building# 17016-10000-19909	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70763	14041-20000-04386	20513 W QUEDO DR	91364	3	169-5A111  64	2166023008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.15891	-118.5797	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70764	16041-10000-16305	7726 N VANALDEN AVE	91335	3	189B121   555	2104009035	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.21119	-118.54903	PV1 INSTALL NEW 8480 W CDC ROOF-MOUNTED SOLAR ARRAY(32) ODULES: CANADIAN SOLAR CS6P-265P(1) INVERTER: SOLAREDGE SE7600A-USP300 is used.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70765	10041-10000-14070	100 SWINFORD ST BERTH 93A	90731	15	018B201   130	7440026903	M2-1, [Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	PIN	33.7478016	-118.27948576	TI AT 100 SWINFORD ST. IN BERTH 93 (DISNEY CRUISE TERMINAL) IN THE BAGGAGE CLAIM AREA. ONE FOR ONE REPLACEMENT OF THE EXISTING HID LIGHT FIXTURES (452W) WITH FLOURESCENT FIXTURES (279W) .  THE EMERGENCY LIGHTS ARE EXISTING. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70766	11041-10002-02065	3833 S CRENSHAW BLVD	90008	10	117B185   719	5045019900	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM			PC Approved	07/06/2012 12:00:00 AM	ADDRESS	34.0162	-118.33546	Changes to approved set of plans. As built.ADD 1416 SF   2ND FLR ADDITION AND TI FOR ADULT EDUCATION.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70767	13041-10000-06865	8820 N DEMPSEY AVE	91343	12	195B141   486	2672016022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Closed	04/06/2015 12:00:00 AM	ADDRESS	34.23075	-118.47735	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.3 KW. USING STANDARD PLAN. 39 PANELS. CENTRAL INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70768	17041-10000-44973	400 S GRAND AVE	90071	14	130-5A211  70	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Public Safety Only			12/14/2017 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.05136	-118.2525	NEW FIRE WARNING SYSTEM FOR NEW ELECTRICAL AND NEW ENGINE BUILDING.SCOPE INCLUDES 90 DEVICES AND 1 PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70769	16041-10000-15622	2501 S WEST VIEW ST	90016	10	123B181   758	5049008056	RD1.5-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM			Reviewed by Supervisor	05/10/2016 12:00:00 AM	ADDRESS	34.03352	-118.34817	(VOID-DM)  7/18/16:  Applicant came for Recheck, but apparently the Design has changed to (62) modules with M215. New Plan check resubmittal is under NEW E# 16041-10000-25122PV2. NEW SOLAR SYSTEM SYSTEM ON EXISTING APARTMENT BUILDING. TOTAL SYSTEM SIZE IS 11.4KWdc / 10.0KWac.(44)MODULES-SOLARWORLD SW 260 POLY(44)OPTIMIZERS- SOLAREDGE P300(1) INVERTER- SOLAREDGE SE10000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70770	17041-10000-25936	208 S LINCOLN BLVD	90291	11	111B145   553	4243014026	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.00177	-118.46833	Plan Check for T24 only, change of use from Autorepair to retail/office/storage. Service is existing, new load is les than 200A. Scope is to install lighting and recpetacles.  (B# 16016-20001-28981)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70771	16041-30000-23877	727 N WILCOX AVE	90038	4	141B185   450	5533035008	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			07/07/2016 12:00:00 AM	07/07/2016 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.08421	-118.33129	Plan check for a fire alarm system for a 4-story apartment building. Fire alarm system consists of (1) FACP, (1) communication panel, and (77) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70772	19041-10000-15060	1320 E NEWTON ST	90021	14	121-5A213 102	5130011033	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.02746	-118.24664	"NEW OFFICE BULDING FOR ""AMERICAN RED CROSS"". NEW SERVICE, 250KW GENERATOR, PANELS, & LOADS. PLAN CHECK FOR POWER & ENERGY. 16,500SQR FT.PLAN CHECK ONLY. PERMIT WAS ISSUED UNDER: 18041-10000-27989BLDG PERMIT: 18016-10000-23726"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70773	16041-10000-00713	1307 N LAGOON AVE	90744	15	033B205   176	7420003025	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	33.78912	-118.26786	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.68KWdc/4.2KWac. (18)MODULES-LIFELINE ENERGY LLE-6M260(1)INVERTER-ABB PVI-4.2-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70774	14041-20001-05245	22341 W DOLOROSA ST	91367	3	174B101   324	2146011003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.1703	-118.61373	(((EXPEDITE FEES)))PV1 MICROINVERTER. TOTAL SYSTEM SIZE 9KWAC. MODULES MOUNTED ON PATIO STRUCTURE, REQUIRES BUILDING APPROVAL PRIOR TO ELECTRICAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70775	17041-10000-00794	1050 N BAY VIEW AVE	90744	15	033B205   975	7420028019	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.10	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2017 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	33.78398	-118.27007	PV1. PC FOR PV SYSTEM. USING TOTAL OF 12 MODULES. MODULES ARE AC TYPE. TOTAL SYSTEM RATING 3.92KW(12)MODULES-SUNPOWER-X21-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70776	11041-10001-25060	17207 W WILLARD ST	91406	6	192B133   458	2204004029	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2012 12:00:00 AM			PC Approved	02/14/2012 12:00:00 AM	ADDRESS	34.21885	-118.50791	updated the plans to show that the sub-panel remained by the patio and the performance meter, ac disconnect, load center, and monitoring panels were relocated around the corner from the sub-panel. Original permit and plan chk are on 11041-20000-25060 Photovoltaic system with modules on the garage, and inverters by service adjacent to main house as on the plans.  The service is being upgraded to 200 amperes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70777	16041-10000-10953	4256 S SAN PEDRO PL	90011	9	114A205   255	5113020009	R2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2016 12:00:00 AM	03/30/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.00633	-118.27084	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.240KWdc / 6.0KWac.(24)MODULES-CANADIAN_SOLAR CS6P-260P(1)INVERTER-SMA SB6000-US-22	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70778	16041-20000-36389	6735 W SELMA AVE	90028	13	148-5A185 274	5547013001	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.09981	-118.33744	remove existing hid fixtures and replace with new led fixtures indoor and outdoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70779	19041-20000-38972	23200 W SHERMAN WAY 23	91307	12	183B093   264	2026001017	(T)(Q)RD3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.19826	-118.63247	Service, power, and energy for model home and sales office.  Plan check for power and energy. B#17010-20001-04396	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70780	18041-10002-36208	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.20	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	01/18/2019 12:00:00 AM	ADDRESS	34.05855	-118.23671	Changes to approved set of plans for ups system block diagram sheet added to drawing with bypass included. Full plan check for data center T.I, Scope includes (1) medium voltage gennerator,  (2) 1200 Board, (6) 1125kva transformers, (2) 4000-Amp board and all other equipment .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70781	12041-10000-25018	758 S MAIN ST	90014	14	127-5A211 219	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/18/2012 12:00:00 AM			PC Approved	10/18/2012 12:00:00 AM	ADDRESS	34.04275	-118.25284	Ti in an existing juice bar. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70782	16041-20003-19283	8101 W MELROSE AVE	90046	5	141B177   568	5528007014	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.08389	-118.36609	Revisions to approved plans.  Addition of shunt trip circuit breaker for elevator short circuit protection.  Approval for clouded delta-2 changes only.  (((COMPLETE REWIRE OF EXISTING BUILDING REMODEL. PER BUILDING, PC IN ACCORDANCE TO 2008 ENERGY CODE. NEW SERVICE AND DISTRIBUTION THROUGHOUT. NEW LIGHTING AND POWER. PC FOR POWER AND ENERGY.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70783	13041-20001-28615	8480 W HILLSIDE AVE	90069	4	148-5A173 303	5558028006	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM			PC Approved	11/05/2013 12:00:00 AM	ADDRESS	34.10114	-118.37318	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.5 KW AC USING 21 MODULES. USING ENPHASE MICROINVERTERS. NONSTANDARD PLNA. 2 STRINGS.(((EXPEDITE FEES)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70784	14041-10001-04149	13180 W TONOPAH ST	91331	6	192B157    34	2627020005	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	34.22685	-118.41971	Expedited RSES plan check per applicant request.{{PV1, Install 4.5 kW DC roof-mounted solar array on a one-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 5000A-US-ZB-U. (18) Modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70785	17041-10002-10065	12035 W WILSHIRE BLVD	90025	11	126B145    25	4265016043	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.04541	-118.46622	Chnages to an approved set of plans. All changes are clouded under delta 2. Changes include resizing feeder conductors from copper to aluminum, adding one EV panel, 6 new EV chargers, revising load calculations, Fully rated to Series rated, and revising electrical room.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70786	16041-10000-29578	127 S SAN VICENTE BLVD 8th-9th	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	12/01/2016 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.07457	-118.37864	PC FOR TITLE 24. SCOPE INCLUDES NEW LIGHTS AND RECEPTECALES. TOTAL OF 4393 SQ.FT 8TH AND 9TH FLOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70787	14041-10000-03334	21001 W SHERMAN WAY	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.20126	-118.59094	Plan check for 'Planned Parenthood' medical facility, consisting of patient care area (multiple exam rooms for medical and clinical care) . Projected area in lighting scope of work is approx. 2218 sf, with emergency lighting. Not an OSHPD facilitiy per applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70788	15041-10001-16968	5700 W HOLLYWOOD BLVD	90028	13	148-5A191 149	5586035036	[T][Q]C2-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.10155	-118.31391	06/30/16Changes include the replacement of a 400 amp switchgear to meet short circuit rating. The new switchgear belongs to the gas station the original permit includes the fueling station not gas station. Dwp to allocate 800 amps to feed both 400 amp boards. Fault current 36,000 per LADWP website. (((FULL PLAN CHECK FOR A NEW HYDROGEN FUELING STATION LOCATED IN AN EXISTING GAS STATION (HAZARDOUS LOCATION). TOTAL SQ FT FOR OUTDOOR LIGHTING: 7200.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70789	16041-10001-45704	3907 W 6TH ST	90020	10	135B193   861	5503019010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.06364	-118.30817	PC FOR T24 ENERGY ONLY. PERMIT ALREADY ISSUED FOR SMALL TI WITH LIGHTING REPLACEMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70790	12041-10000-23466	1935 S ARMACOST AVE	90025	11	123B149   313	4259020015	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/02/2012 12:00:00 AM	12/14/2012 12:00:00 AM		Permit Finaled	07/01/2013 12:00:00 AM	ADDRESS	34.03542	-118.45478	Plan check single story commercial TI for power, service, lighting, panels and Title 24 Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70791	14041-10001-17121	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/11/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	09/28/2022 12:00:00 AM	ADDRESS	34.03941	-118.25893	Changes to approved set noted under delta-13& delta 17. Scope includes:(1) Increase electrical rating of the fire pump, revise feeder and OCPD size accordingly(2) Add New 15 KVA xfrmr(3) Add New 100A panel with 10 ckt(4) Remove and add few circuitry<<Renovation of an existing 13 story Club building. Change of Use to Hotel with restaurant on 1st floor,  New Restaurant on Roof with spa/pool.  New bar in Basement (core and shell only)>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70792	19041-10000-42101	749 S BROADWAY	90014	14	127-5A209  96	5144014028	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Info Complete	11/27/2019 12:00:00 AM	ADDRESS	34.04418	-118.25458	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI SCOPE OF WORK INCLUDES NEW LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 3061 SFQT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70793	14041-10000-21078	6400 N OWENSMOUTH AVE A-C	91367	3	180B105    64	2146005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	34.18653	-118.6013	Tenant improvement of existing commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70794	14041-20000-09058	20661 W CAMPANIA LANE	91326	12	213B109   546	2701070053	[T]RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.2805	-118.58362	PV1.  Install 4.94 kW DC roof-mounted PV system, interconnect with main service panel.  Microinverter standard plan.  Enphase M215-60-2LL.  22 modules: SunEdison SE-F270CyC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70795	16041-20004-26775	327 S HOOVER ST 1-48	90020	13	136-5A201 207	5501022007	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			04/19/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.06799	-118.2845	"4/19/2017Changes to an approved set of plans.  Changes reflect current field conditions.  This is plan check only.((('0$ permit fees due to senate bill 1222""Plan check for PV roof mounted system. System size: 40kW with 176 modules and 4 inverters(10.0kW) connected to MSP)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70796	15041-10001-26630	3959 W WILSHIRE BLVD B5	90010	10	132B193    31	5504027020	C4-1	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.06186	-118.31337	Change to approved set by modifying the lighting fixture on the floor plan. All changes are under delta-1 only.(((Energy plan check for a retail (coffee shop) T.I ; Scope includes new lighting and receptacles, Total area is 800-SQ feet.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70797	19041-10000-53267	800-816 N VERMONT AVE	90029	13	141B197   160	5539015022	[Q]C2-1	Central	Hollywood	East Hollywood		1914.20	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM	11/05/2020 12:00:00 AM		Permit Finaled	10/23/2023 12:00:00 AM	ADDRESS	34.08581	-118.2915	POWER ONLY PC FOR REPLACING SEVERAL EXISTING SERVICE WITH NEW 800 AMP 120/208V 3PHASE 4WIRE SERVICE. SCOPE OF WORK INCLUDES INSTALLATION OF NEW PANELS. EXISTING CIRCUITS TO REMAIN AS IS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70798	16041-20000-06487	4504 N COLBATH AVE	91423	4	168B153   828	2271004018	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			02/24/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.1533	-118.43644	NEW 12 UNIT APTS. 3 STORY OVER ON-GRADE GARAGE (BUILD-UP SIDEYARDS) BASEMENT GARAGE.  PLAN CHECK FOR POWER AND ENERGY.  FIRE ALARM VARIANCE HAS BEEN FILED 02/24/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70799	19041-10000-11375	5410 W ADAMS BLVD	90016	10	123B177  1048	5043008019	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	12/23/2020 12:00:00 AM		Permit Finaled	04/28/2022 12:00:00 AM	ADDRESS	34.03227	-118.36093	Energy plan check for a change of use from market to restaurant. Scope includes new lighting and equipment with a total area of 1934-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70800	18041-10000-15974	15934 W STRATHERN ST	91406	6	189B141    76	2206006010	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.21559	-118.48068	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70801	13041-20000-13066	8900 N DE SOTO AVE BLDG 101S	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	07/25/2013 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for new industrial facility. Pratt Whitney Rocketdyne. Building 101 South. PC fees per applicant. NOT methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70802	11041-20002-11995	14141 W VENTURA BLVD	91423	4	165B153   388	2265020006	(T)(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.00	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	"Modification to previously approved set of plans to add an 800 amp service.  All 1st time tenants will require full plan check. (Plan check for ""Delta 1"" Only)  <<<<<<NEW COMMERCIAL/RESIDENTIAL MIXED USE BUILDING.  113 UNITS, 4-STORY.  >>>>>>>>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70803	17041-10000-15696	249 S LOS ANGELES ST	90012	14	129A213    47	5161026910	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	07/15/2020 12:00:00 AM	ADDRESS	34.04908	-118.24445	Plan check for power and Title 24.  New 2 story gymnasium and community center.  Two new 600 amp 480/277 volt services. Total affected area is 63044 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70804	18041-20001-35225	8050 N MAMMOTH AVE	91402	6	189B157   126	2213017016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.21777	-118.43195	Expdite per applicant requestPlan check for PV roof mounted system and battery storage system. PV system size: 9.6kW AC with 30 PV modules,30 Microinverters and 2 battery storage energy Tesla PowerWall 2.0 13.2kWh(2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70805	14041-10000-11965	6500 W WILSHIRE BLVD	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/16/2014 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.06371	-118.3703	Title improvement to existing office building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70806	14041-20000-19019	4325 N WOODMAN AVE	91423	4	165B157   536	2271018011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.14885	-118.43146	Energy for empty tenant spaces in (E) commercial building.  Plan check in conjunction with 14041-20000-19023.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70807	16041-20000-40750	22842 W LEADWELL ST	91307	12	186B097   863	2021020007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.20331	-118.62509	PV1.  Install 7.6 kW AC roof mounted grid-tied PV system.  (34) modules with (1) 7.6 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70808	18041-10000-00476	19231 W VICTORY BLVD STE 151,-155	91335	3	180B117   799	2128031153	(Q)C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.18678	-118.55214	PC FOR SUITE 151+155 TENANT IMPROVEMENT FOR (E) MEDICAL OFFICES.  SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTING. TOTAL AFFECTED AREA 3119 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70809	17041-30000-17151	11924 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			PC Approved	05/23/2017 12:00:00 AM	ADDRESS	34.05236	-118.47067	Plan check for Title 24. T.I. Existing space. Total area: 980 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70810	17041-20000-22700	11454 N DORAL AVE	91326	12	213B121   457	2822031026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.27976	-118.54874	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.6 kWacNote: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70811	14041-20001-31475	3071 N CHADWICK DR	90032	14	141A235    67	5218005041	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.04	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2015 12:00:00 AM			PC Approved	03/06/2015 12:00:00 AM	ADDRESS	34.08139	-118.17246	PC only for restamp of lost plans.***Original description of work***PV1Install a roof-mounted solar array on a SFD. Interconnect with 225 MSP.System size: 8.6kW. Ungrounded system.(40) EnPhase M215-IG microinverters with (40) 250W pv modules across 3 strings (15+11+14).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70812	17041-10000-02875	8417 W MELROSE PL	90069	5	141B173   443	5528002040	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	01/27/2017 12:00:00 AM	ADDRESS	34.08377	-118.37377	Title 24 plan check.  T.I. to existing retail space.  New panelboard with lighting and receptacles.  Total area = 952 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70813	17041-20001-17297	5012 N MAMMOTH AVE	91423	4	171B157  1013	2269002020	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM			PC Approved	06/05/2017 12:00:00 AM	ADDRESS	34.16154	-118.43229	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system with dc coupled battery backup for SFD.6kW ungrounded system. (18) 325W pv modules. (1) 5kW Tesla Powerwall backup battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70814	14041-20001-13842	12554 W COLLINS ST PV1	91607	2	174B161   308	2341016008	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.17384	-118.40731	((expedite fees)))INSTALL ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM (9.72KW) using 2 central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70815	17041-10000-32835	6434 W INNSDALE DR	90068	4	159B185   137	5577038020	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.12986	-118.33045	PC FOR PV SYSTEM USING 11.4KW AC CENTRAL INVERTER. TOTAL OF 40 MODULES. 14.6KW DC	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70816	14041-20000-02288	5226 N BECKFORD AVE	91356	3	171B117   239	2163009010	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Expired	03/16/2016 12:00:00 AM	ADDRESS	34.16583	-118.55162	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 10KW AC USING 2 TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70817	17041-10000-10301	540 S COMMONWEALTH AVE	90020	13	135A201   133	5077005028	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	05/11/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.06395	-118.28551	PC FOR A NEW FIRE ALARM FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES 58 FA DEVICES, AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70818	14041-20000-17753	3780 W WILSHIRE BLVD Ste 601	90010	10	132B193    69	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			Corrections Issued	06/30/2014 12:00:00 AM	ADDRESS	34.06153	-118.30852	TI to (E) commercial office space in highrise office building.  Plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70819	16041-20003-02777	620 S VIRGIL AVE	90005	10	135A201   140	5077007029	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Apartment			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	34.06288	-118.28683	Revisions to approved set of plans.  Additional monitor modules, removal of devices from tenant lease space, and miscellaneous changes.  Approval for delta-4 revisions only.   (((SUPPLEMENTAL PERMIT TO 16041-10000-02777 FOR CHANGE OF ADDRESS FROM 2968 W 6TH STREET TO 620 S VIRGIL AVE.  NO CHANGE IN LEGAL DESCRIPTION.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70820	15041-20000-34238	209 S LORING AVE	90024	5	141B153   306	4359001028	R1-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Permit Finaled	01/19/2019 12:00:00 AM	ADDRESS	34.07848	-118.43732	Plan check for 800A service  for new single family dwelling New three story SFD with attached garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70821	17041-10000-00273	2727 W PICO BLVD	90006	1	129B197  1040	5078034032	[Q]C2-2	Central	Wilshire	Pico Union		2133.10	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.04739	-118.29828	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA (OUTDOOR) 11600 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70822	18041-20001-08181	11350 W PALMS BLVD	90066	11	117B157   350	4249026028	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	09/28/2018 12:00:00 AM	ADDRESS	34.01769	-118.42601		N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70823	12041-10001-31230	8232 N WHITE OAK AVE	91325	12	192B129   323	2201001032	(Q)C2-1VL, C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Commercial			07/17/2013 12:00:00 AM			PC Approved	07/23/2013 12:00:00 AM	ADDRESS	34.22023	-118.51841	"MODIFICATION TO APPROVED SET OF PLANS. LUMINAIRE COUNTS AND AREA SQUARE FOOTAGE CHANGED DUE TO CHANGE OF SIZE OF ELECTRICAL ROOM.************************************************************************TENANT IMPROVEMENT FOR ""DOLLAR TREE""  RETAIL STORE.  LESS THAN 100 OCCUPANTS.  T24 FOR LIGHTING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70824	07041-10001-00260	7401 S SEPULVEDA BLVD	90045		102B165   569	4110003007	RD1.5-1XL		Westchester - Playa del Rey	Westchester - Playa del Rey			Electrical	Electrical	Apartment			06/09/2010 12:00:00 AM			PC Info Complete	06/10/2010 12:00:00 AM	ADDRESS	33.97414	-118.39462	Change to the priviously approved plan. Change the distribution board to 12000 Amp relocate the house panel. Plan check for delta 2. ((((((((((((((((((NEW 24-UNIT / 2-STORY APARTMENT WITH SUBTERRANEAN GARAGE.))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70825	14041-10000-26838	6415 W RODGERTON DR	90068	4	157-5A189 269	5582012016	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.12396	-118.32286	PV1 9.66KW roof-mounted system including (28) Sunpower X21-345 modules and (2) SB5000TL  inverters interconnecting through a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70826	18041-10000-06428	14006 W RIVERSIDE DR #65	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	PC for T24 only for existing retail space. Installing new lights, receptacles,  and equipment. Total  4795sqft. B# 18016-10000-05316.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70827	12041-20000-13479	760 N GREENTREE ROAD	90272	11	126B129   339	4409022014	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.04286	-118.51569	pv system 8.82 kw single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70828	17041-10000-06203	2049 S CENTURY PARK EAST 6th FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Issued	03/07/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC for TI 24 only in office area corridors. Luminaire replacement to lower rated luminaires, one for one replacemetn. Total affected area is 1710 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70829	11041-20000-09900	3743 S LA BREA AVE 1ST FLOOR	90016	8	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2201.00, 2360.00	Electrical	Electrical	Commercial			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	08/16/2011 12:00:00 AM	ADDRESS	34.01873	-118.35577	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY LIGHTING) FOR TENANT IMPROVEMENT TO OFFICE ON FIRST FLOOR. PERMIT FOR NEW DEVICES/FIXTURES ON EXISTING CKTS. NEW WATERHEATER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70830	11041-10000-19911	2175 W COLORADO BLVD	90041	14	162A223   101	5671012029	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.13932	-118.21389	T.I. FOR A NEW CHASE BANK.  SERVICE IS EXISTING.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70831	14041-20000-23138	222 S MAIN ST	90012	14	130-5A213 144	5161026039	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/28/2014 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.05047	-118.2448	Plan check for power and energy. New 239 unit, 7-story apartment building. 130,000sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70832	17041-10000-37703	725 S FIGUEROA ST # 3275	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.04886	-118.26071	ALTERATIONS IN EXISTING OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70833	17041-10001-00209	18555 W VENTURA BLVD	91356	3	174B125   543	2160007037	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/25/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.1697	-118.53779	PC for power and energy for a medical office  TI . Permit was pulled under express permit.  scope includes new lights and receptacles. Total affected area of 2271 sq.ft.Bld app # 16016-20000-28668	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70834	17041-10000-25810	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM			Reviewed by Supervisor	08/15/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	LAX POROJECT PC FOR POWER AND ENERGY FOR A COFFEE KIOSK IN TERMINAL 2.ASSIGNED TO MEHDI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70835	10041-10000-22137	3780 W WILSHIRE BLVD Parking-Building	90010	10	132B193    69	5093006030	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	ADDRESS	34.06153	-118.30852	Install a new 80 kw emergency generator to replace an existing UPS system, a new 100 ampere emergency ATS, transfer the # 5 elevator circuit from existing panel L1 to the existing panel EM, and transfer a stair lighting circuit from panel L1 to panel EM.  See page A3.0.   Transferred loads are identified as 'n' on the panel EM schedule.  No other work to be done, and no new loads added to the base building electrical system.  The elevator and  lighting circuit shall be extended to panel EM using the same wire and conduit type. The work is done in a parking structure adjacent to the Wiltern Theater.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70836	10041-20000-15565	801 S GRAND AVE Suite 530	90017	14	127-5A209 312	5144020***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/10/2010 12:00:00 AM			PC Approved	11/10/2010 12:00:00 AM	ADDRESS	34.04581	-118.25842	lighting office areas. p/c is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70837	12041-10000-15650	7540 S COWAN AVE	90045	11	102B165   553	4110015053	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	33.97407	-118.40572	Plan check for  5.886kW DC Photovoltaic system. Single Family dwelling. Roof mounted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70838	14041-10000-26719	1150 S BEVERLY DR	90035	5	132A167   103	4330031040	C2-1VL-O, R4-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM			PC Approved	09/26/2014 12:00:00 AM	ADDRESS	34.05621	-118.39569	Title 24 plan check only. Total area = 1491 sq. ft. Rework landscape lighting and prte cochere lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70839	18041-20001-26258	505 W 31ST ST	90007	9	120A203    80	5123020009	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			08/16/2019 12:00:00 AM	06/29/2021 12:00:00 AM		Permit Finaled	08/26/2021 12:00:00 AM	ADDRESS	34.02382	-118.27755	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CLOUDED DELTA B CHANGES ONLY. CHANGES MADE TO SINGLE LINE, PANEL SCHEDULE, ELEVATION DRAWINGS, VOLTAGE DROP CALCS, LOAD CALCS, FAULT CALCS, BASEMENT FLOOR PLAN, 1ST FLOOR PLAN, AND LOUNGE PLAN. ADDITION OF A FIRE PUMP, JOCKEY PUMP PANEL, AND RELOCATION OF OTHER PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70840	19041-10000-21505	6325 W SANTA MONICA BLVD 1ST &2ND-FLOORS	90038	13	144B185   700	5533007036	C2-1D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Info Complete	06/10/2019 12:00:00 AM	ADDRESS	34.09087	-118.32754	TENANT IMPROVEMENT TO (E) TYPE IIIB SCHOOL BUILDING ( 2-FLOORS )ADDING WALLS LUMINAIRES HVAC UNITS AND BRANCH CIRCUITS TO EXISTING PANELBOARDS. ADDED LOAD IS LESS THAN 200A. TITLE 24 PLAN CHECK - TOTAL AFFECTED AREA 14350SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70841	18041-10001-34803	521 N ROCKINGHAM AVE	90049	11	135B137   472	4406004001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2018 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.06464	-118.49068	(((EXPEDITE FEE)) NEW 13.98 KW ROOF MOUNTED PV SYSTEM WITH 43 PV PANELS AND 54 KWH ENERGY STORAGE SYSTEM CONNECTED TO THE EXISTING 600 AMP SERVICE ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70842	10041-10000-11199	11601 W WILSHIRE BLVD 710	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/14/2010 12:00:00 AM			PC Approved	06/14/2010 12:00:00 AM	PIN	34.0509267	-118.45996763	new luminaires,outlets, switches relocate luminaires;plan chk is for title 24; permit was obtained on 10041-90000-10079	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70843	17041-10000-33522	7120 S BROADWAY	90003	9	102B201   838	6012013062	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	33.97496	-118.2781	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70844	12041-20001-00366	8401 N VAN NUYS BLVD	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			03/13/2012 12:00:00 AM			PC Approved	03/13/2012 12:00:00 AM	ADDRESS	34.22308	-118.44896	Changes from previously approved plans.  Changes include relocate some light fixtures.  All changes are clouded and indicated by DELTA-3 as shown on plans.  Plan check for energy only.*****T.I. for existing retail (The Children's Place).  Install indoor general/emergency lighting. Plan check for energy only.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70845	14041-20002-05065	2000 N LAS PALMAS AVE	90068	4	150A185   143	5575011017	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West	YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.10631	-118.33622	Revisions to approved set.  Not enough room for PV breaker in main service panel, transfer of PV breaker to (E) sub-panel.  Modifications to sheet 5 of 8 only.  $0 submittal fee is due to State Senate Bill SB-1222.  (((PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.78KW AC USING A COMBINATION OF MICROINVERTERS M215 AND CENTRAL TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70846	10041-20000-20772	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM			PC Info Complete	10/19/2010 12:00:00 AM	ADDRESS	33.78808	-118.29535	Plan check requested by customer for new UPS system to supply low voltage network and equipment associated with UPS installation on 1st floor and 2nd floor. Installation does not impact patient care area and life safety.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70847	11041-10000-18990	9301 N TAMPA AVE #106	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	12/16/2011 12:00:00 AM		Permit Finaled	04/08/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	TI IN AN EXISTING RESTAURANT IN UNIT # 106.  PLAN CHECK IS FOR T-24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70848	17041-20000-21599	6919 N BIRCHTON AVE	91307	12	183B093   601	2028012025	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.1948	-118.64148	plan check for power.  addition of back up battery (5.8kw powerwall) to an existing pv syetm.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70849	19041-20000-09590	10652 N JOHANNA AVE pv1	91040	7	207B181   123	2549008003	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2019 12:00:00 AM	03/18/2019 12:00:00 AM		Issued	03/18/2019 12:00:00 AM	ADDRESS	34.263	-118.34746	pv1install ground mount pv system sized 5.8KW AC interconnecte with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70850	16041-20002-26771	421 N HELIOTROPE DR 1-60	90004	13	141B197  1173	5520016022	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Apartment			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.07839	-118.29606	changes to an approved set of plans.  changes include downsize (1) inverter to 8kw and reconnect to msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70851	10041-20000-14864	21300 W VICTORY BLVD #400	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			07/30/2010 12:00:00 AM	07/30/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.18813	-118.59618	enrgy plan check Unit # 400	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70852	17041-30001-33888	10101 W CHEVIOT DR	90064	5	123B165   236	4316015018	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2017 12:00:00 AM			PC Approved	11/01/2017 12:00:00 AM	ADDRESS	34.03571	-118.40413	Expedite per applicant requestPlan check for PV roof mounted system of SFD. System size: 11.4kW with 46 modules Solarworld SW295 MONO 295 modules and 1 inverter(11.4kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70853	18041-30000-26145	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	33.94558	-118.4039	Energy plan check for the hold room located in LAX Terminal-2. Scope includes retrofitting (2) type fixture with a total area of 32,500 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70854	17041-10000-41007	6301 W 3RD ST	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/13/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Issued	11/16/2017 12:00:00 AM	ADDRESS	34.07243	-118.35963	PC FOR METHAN DETECTION SYSTEM TOTAL OF 7 NEW DEVICES ON EXISTING SYSTEM. B# 17016-30000-16682	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70855	14041-10000-20066	15344 W RAYMER ST	91406	6	189B145   732	2222001011	PF-1XL	South Valley	Reseda - West Van Nuys	Van Nuys		1273.00	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.21494	-118.46738	Remove HID light fixtures and replace with new fluorescent fixtures. Title 24 plan check. Area = 19519 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70856	16041-10000-19467	10866 W WILSHIRE BLVD #1560	90024	5	132B153   359	4325005074	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/03/2016 12:00:00 AM			PC Approved	06/03/2016 12:00:00 AM	ADDRESS	34.05907	-118.442	Energy plan check installing new lighting and receptacles to High rise building suite 1560 (offices). Total sqft = 2083NOTE: PC only, permit paid umder application #16041 40000 18705.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70857	16041-20000-32443	1751 S MALCOLM AVE bldg 2	90024	5	129B153   378	4325023017	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			08/22/2016 12:00:00 AM			PC Approved	07/27/2018 12:00:00 AM	ADDRESS	34.05084	-118.43544	PLAN CHECK AND PERMIT FEES FOR THE (2) BUILDINGS COVERED UNDER APPLICATION NUMBER 16041-20000-29790(((New apartment building 1200 amp service for (2) buildings connected by commoin roof.  plan check for power and energy.Building application numbers under 16010-20000-02308/09)))	N	N	Express Permit	06/10/2024 12:00:00 AM
70858	13041-10001-18163	9301 N TAMPA AVE # 193	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/02/2013 12:00:00 AM			PC Approved	10/02/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	TITLE-24 PART 6 , PLAN CHECK-ONLY. SCOPE OF WORK < 400A. CHANGES MADE TO AN APPROVED SET OF PLANS. CHANGES INCLUDES REPLACING ALL FIXTURES. SCOPE OF WORK IS FOR  INTERIOR REMODEL OF EXISTING TENANT SPACE, TITLE 24 AND EMERGENCY LIGHTING; NON-HIGH RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70859	15041-10001-16207	7280 W MELROSE AVE	90036	5	141B181   623	5525013027	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Approved	09/22/2015 12:00:00 AM	PIN	34.08325977	-118.34845856	((9/22/2015))CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 2 PER INSPECTOR REQUEST.    CHANGES INCLUDE AIC RATING FOR EQUIPMENT AND RATING OF PHASE CONVERTER.  THIS IS PLAN CHECK ONLY.TI TO AN EXISTING TWO STORY COMMERCIAL BUILDING.  NEW 600 AMP SWITCHGEAR, NEW PANELS AND CIRCUITS.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 3865.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70860	18041-20000-16562	7600 N BALBOA BLVD #204	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Plan check for first time tenant retail space new lighting and receptacle. Total area: 1040 sq ft.B#18016-10000-13841	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70861	17041-10000-46588	529 N BROAD AVE	90744	15	030B205   912	7418006023	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	33.77664	-118.26103	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70862	19041-20000-03933	2450 N SUMMITRIDGE DR	90210	4	153B157    36	4386014046	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	10/02/2019 12:00:00 AM	ADDRESS	34.11852	-118.42251	Plan check for a PV1 roof-mounted PV system. System size is 44.88 kWdc / 41.1 kWAC-CEC and consists of (1) 43.2 kWAC rated inverter and (136) modules.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70863	12041-10000-08417	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			04/12/2012 12:00:00 AM	05/24/2012 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	New motor loads to panel at LAX - Bradley -West Gates.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70864	10041-20000-20934	16350 W VENTURA BLVD Unit C	91436	5	168B137   410	2284001055	C4-1L	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	ADDRESS	34.15688	-118.48955	First time tenant for Personal Training Institute.  Install branch circuits and general/emergency lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70865	17041-10000-05979	7359 N FULTON AVE	91605	2	186B157   360	2328029027	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	07/31/2018 12:00:00 AM		Issued	07/31/2018 12:00:00 AM	ADDRESS	34.20464	-118.42265	PC for power only to exiting commercial building. Service Upgrade to 800 Amps120/240V and installing 3ea new 400A panels A,B,P, and connecting existing  loads to panel P. Existing equipment also reflected on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70866	15041-20000-27765	15407 W HART ST	91406	6	183B145   326	2222034021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Expired	09/22/2017 12:00:00 AM	ADDRESS	34.19765	-118.46878	PV1. Install roof mounted PV system sized 5(22) Kyocera KU265 Modules(1) ABB PVI-5000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70867	12041-10000-20291	11766 W WILSHIRE BLVD	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.01	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.04804	-118.46227	REMODEL EXISTING OFFICES  ON 10TH FL-NO CHANGES IN THE EMERGENCY SYSTEMPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70868	17041-10000-09941	910 S BROADWAY	90015	14	127-5A209 260	5139002017	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.04197	-118.25618	PC for energy only, Indoor Title 24. TI on first floor and mezzanine level. Retail is located on level one. Conference and breakroom on mezzanine level 2. New lighting and power. Area: 3459 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70869	10041-10003-22559	4501 W COLORADO BLVD BLDG  8	90039	13	162B205    19	5593012033	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/21/2013 12:00:00 AM	ADDRESS	34.14246	-118.2705	MODIFICATION TO APPROVED SET OF PLANS. REVISIONS TO SHEETS G001-EL,  44-0602-102, 44-0602-104, 44.0602-204, 44.0602-206. MODIFICATION IS TO LIGHTING CONTROLS ONLY. CHANGES ARE CLOUDED.******************************************************DESCRIPTION: REVISIONS TO LIGHTING PLANS- MODIFICATION TO ALLOW ANNUNCIATED LIGHT SWITCHES LOCATED IN A CONTROLLED ACCESS ELECTRICAL ROOM ON THE IST FLOOR  TO MEET TITLE 24  AREA LIGHTING CONTROL; DELTA 14 CHANGES((((((((( NEW 2-STORY MANUFACTURING FACILITY WITH PARTIAL BASEMENT AND TWO EQUIPMENT PLATFORMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70870	15041-10001-24066	1500 W PACIFIC COAST HWY Bldg G	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION of 39 devices and 1 power supply for future ADA requirement(((NEW FA SYSTEM FOR A New 3-story, 15 unit apartment with garage, . 41 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70871	19041-10000-34124	827 S UNION AVE	90017	1	130-5A205 183	5142017023	R3-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Permit Finaled	11/07/2020 12:00:00 AM	ADDRESS	33.9787	-118.31759	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70872	15041-10000-03688	2435 N CREST VIEW DR	90046	4	153B169   273	5564015022	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.11606	-118.3896	Installation of roof mounted solar PV array.  Total system size = 6.6 kWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70873	13041-10000-34162	1358 W PACIFIC COAST HWY	90710	15	033B193    81	7411007066	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	33.78922	-118.30076	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 3320 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70874	10041-30000-00272	11301 W PICO BLVD	90064	11	123B153   214	4260021021	[Q]M2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	03/01/2010 12:00:00 AM	ADDRESS	34.03517	-118.43924	TI - existing Best Buy remodel of area clouded in plans - Permit is for new panel, new equipment + 75 kVA XFMR, new ckts, new lightingis for display only.  New load is < 400 A.  P/C is for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70875	15041-20000-14379	5424 S CRENSHAW BLVD	90043	8	108B185   458	5006008008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.99235	-118.33045	PC FOR PV SYSTEM. 1.5KW AC USING SINGLE TRANSFORMERLESS INVERTER. THIS SYSTEM CONNECTS TO TENANT AT 5424 CRENSHAW. THIS IS PROJECT 3/5. ALL SYSTEMS CONNECT TO SINGLE 400A SINGLE PHASE SERVICE. ZONING AND CRA HAVE BEEN COMPLETED UNDER PROJECT 1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70876	18041-10001-03456	14459 W TYLER ST	91342	7	225B149   160	2504004016	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	34.31511	-118.44808	supplemental to changes to approved set of plan to re-rout conductors feeding pv system onlyPV1 ROOF MOUNTED SOLAR SYSTEM USING AC MODULES. (35) AC MODULES AND A NEW LOAD CENTER. TOTAL SYSTEM SIZE 12.075KAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70877	10041-20000-16531	13400 W WASHINGTON BLVD	90292	11	108B153  1318	4230003077	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	08/23/2010 12:00:00 AM		Permit Finaled	10/23/2010 12:00:00 AM	ADDRESS	33.99158	-118.44484	lighting in salon. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70878	18041-20001-07899	13636 W BAYLISS ROAD	90049	11	138B133   166	4492016006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM			PC Approved	03/14/2018 12:00:00 AM	ADDRESS	34.07617	-118.50755	SUPPLEMETAL TO EXPEDITE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70879	16041-30000-05728	1880 CENTURY PARK EAST SUITE 700-710	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	PIN	34.0617399	-118.41400349	Title 24 plan check only.  Total area = 7,092 sq. ft.TENANT IMPROVEMENT TO EXISTING OFFICE SPACE.  New lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70880	18041-20000-17330	1143 S GLENVILLE DR 1-13	90035	5	132A167   188	4330035009	R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM	09/24/2019 12:00:00 AM		Permit Finaled	05/26/2021 12:00:00 AM	ADDRESS	34.05586	-118.39307	Plan check power and energy new 13 units appartment building. Total area: 8055 sq ftB#14010-30000-03954	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70881	19041-10000-13794	110 S BARRINGTON AVE	90049	11	135B145   573	4401006020	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.06502	-118.46967	PC T-24 only for chevron store. scope area 1562.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70882	15041-20000-12271	9265 W ROBIN DR	90069	4	147B169   158	5561006013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2015 12:00:00 AM			PC Info Complete	01/05/2016 12:00:00 AM	ADDRESS	34.10131	-118.39162	Power plan check for new single family dwelling with 600 A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70883	13041-20000-11006	2835 S BARRY AVE	90064	11	120B153   865	4258009023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2712.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2013 12:00:00 AM	06/04/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.0238	-118.43847	photovoltaic system for single family dwelling pv1. transformerless inverter nonstandard plan. total system size 5 kw. using 20 modules. roof mounted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70884	14041-20002-11887	4732 N ARCOLA AVE	91602	4	168B177   610	2420023002	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM			PC Approved	06/18/2014 12:00:00 AM	ADDRESS	34.15678	-118.3548	Modification to approved set.  PV system connection to service equipment modified from approved set, plan check approval only to be given to modified portion of single line diagram and service load calcs only.(((PV1 ROOF MOUNTED MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 7.5KW)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70885	18041-20000-16736	7128 N VAN NUYS BLVD	91405	6	183B149   808	2217007040	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			05/07/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.20002	-118.44856	Interior tenant improvement of (E) retail space into restaurant.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70886	17041-10000-02387	7965 1/2 W MELROSE AVE	90046	5	141B177   536	5527013004	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.08392	-118.36331	Plan check for energy only change of use from retail to restaurant. New lighting and power. Area: 642	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70887	13041-10000-03693	8631 W 3RD ST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	03/19/2013 12:00:00 AM		Issued	03/19/2013 12:00:00 AM	ADDRESS	34.07373	-118.38036	.UPGRADE OF 12 NEW MOTORS ON ROOF OF MEDICAL OFFICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70888	14041-20000-29388	7317 N SEPULVEDA BLVD	91406	6	186B145   698	2222021004	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Apartment			10/23/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	PIN	34.20349842	-118.4668069	PV2Install roof-mounted solar array on existing apartment building. System size: 22.8kW (11.4+11.4). Inverters have transformers. 88 305W pv modules. 4 strings of 11 modules per inverter. Interconnect with existing 600A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70889	15041-10002-01050	12550 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.97815	-118.41197	((((5/10/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO ENERGY CALCULATIONS, OCCUPANCY SENSORS AND LIGHTING SWITCHES.  THE CHANGES APPLY TO ALL THE FOLLOWING APPLICATION NUMBERS AS NOTED BELOW.Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70890	16041-20000-41000	10253 ANGEL LANE	91331	7	204B165   436	2537004046	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25686187	-118.40472925	pv1install roof mounted pv system sized 3.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70891	14041-20000-21210	23330 W HATTERAS ST	91367	3	174B093   142	2041008002	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.17537	-118.63518	PV1.  Install 9 kW roof-mounted, utility-interactive PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70892	14041-20000-07073	5080 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM			No Progress	05/19/2014 12:00:00 AM	ADDRESS	34.02028	-118.35491	Install general lighting in Starbucks area inside Ralphs supermarket.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70893	14041-10000-25696	12558 W FIELDING CIR	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/18/2014 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	33.97812	-118.41195	PLAN CHECK FOR FIRE ALARM SYSTEM FOR APARTMENT COMPLEX WITH MULTIPLE BUILDING WITH MULTIPLE ADDRESSES. THIS IS BUILDING 1 OF 7. ALL BUILDING UNDER ONE SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70894	13041-20000-21333	820 S BROADWAY	90014	14	127-5A209 169	5144016063	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM			Reviewed by Supervisor	09/17/2013 12:00:00 AM	ADDRESS	34.04311	-118.25507	ELECTRICAL SERVICE UPGRADE. NEW SERVICE, AND MAIN DISTRIBUTION SECTION. PART OF HIGH RISE. PC FOR POWER ONLY. NEW PANELS. NO NEW CIRCUITS. LOCATED IN METHANE BUFFER ZONE. NEW UNDERGROUND PULL SECTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70895	12041-10000-11071	1329 S SANTEE ST	90015	14	124-5A209 226	5133017015	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM			PC Approved	05/15/2012 12:00:00 AM	ADDRESS	34.03448	-118.25903	T.I. to an existing Retail with Warehouse space.  Change to lighting and receptacle load.  No change to load.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70896	16041-20000-14353	9400 N PENFIELD AVE	91311	12	198B113    95	2761040017	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.24112	-118.56938	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PC FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 15645.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70897	15041-10001-34860	7843 N LANKERSHIM BLVD Apartment-Bld	91605	6	189B169   517	2310025034	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Apartment			12/19/2016 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.21329	-118.38805	***Changes to approved set:(1) light fixture changes(2) resize elevators' power(3) add generator (4) add oil cooler for elevators(5) add panels<<Full plan check for a 49 stuido units and (1) 2-bedroom unit. the site plan includes a residential building and a  2-story commercial building sharing a common underground parking. Scope includes a 5000-Amp service 120/208V 3-phase 4-wire. with 6-typical unit. total area for T-24 is 55032-SQ feet.BUILDING PERMIT #15010-10000-03727COMMERCIAL APPLICTION # : 15041-10000-35250>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70898	16041-20000-21240	10354 W DIAMOND ST LOT 18	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70899	18041-20000-37038	7212 N DE SOTO AVE	91303	3	183B109    42	2113013002	C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Issued	09/27/2018 12:00:00 AM	ADDRESS	34.20151	-118.58826	Plan check for Title 24 only. Project site is existing outdoor hardscape area. Scope of work is outdoor lighting. Total lighting area = 7,715 sq. ft.Note: Partial electrical permit fees have been paid under 18041-90000-26288	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70900	15041-20000-01806	10530 W VICTORY BLVD SUITE 201	91606	2	177B177    90	2414019012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			01/21/2015 12:00:00 AM			Reviewed by Supervisor	03/02/2015 12:00:00 AM	ADDRESS	34.18498	-118.36061	INSTALL OF 12KW DC PV SYSTEM. ROOF MOUNTED. TO NET METER SUITE 201 USE.  TOTAL OF 48 MODULES. THIS INTERCONNECTED TO A SINGLE PHASE SERVICE. PER APPLICANT, BUILDING HAS 2 INDEPENDENT SERVICES. SYSTEM USES 10KW AC INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70901	16041-20002-21799	10646 W STALLION RANCH ROAD	91040	7	204B177   255	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.25903	-118.36199	08/25/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta D. Branch circuit for ct monitoring system has been removed. *****Previous Work Description*****PERMIT FEE $0.00 STATE SENATE BILL NO.1222PV1.  Install roof mounted PV system.  (86) modules with microinverters.  (1) solar monitoring circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70902	17041-10000-02933	11601 W WILSHIRE BLVD STE 1675	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM	01/30/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	OFFICE TI. NEW LIGHTING. PC FOR T24 ENERGY ONLY. PER BUILDING PERMIT, PC IN ACCORDANCE WITH 2013 ENERGY STANDARDS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70903	18041-10000-39745	1040 N LAS PALMAS AVE BLDG 14	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.09003	-118.33615	PLAN CHECK FOR T24 ONLY,  TENANT IMPROVEMENT OF AN EXISTING OFFICE SPACE (NO CHANGE OF USE), TOTAL AREA: 791 SQ.FT(B# 18016-10000-26059)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70904	15041-20000-39254	19550 W NORDHOFF ST	91324	12	195B117     9	2783028062	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Closed	06/14/2018 12:00:00 AM	ADDRESS	34.23529	-118.55947	NEW PARKING STRUCTURE-3 STORY, Full PC, Total area: 202,245 sq.ft. (E)MS 1600A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70905	16041-10000-02622	4202-4212 W JEFFERSON BLVD	90016	10	120B181   765	5046007003	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.02542	-118.34196	SERVICE UPGRADE 800 AMPS TO AN EXISTING BUILDING.  ADDING NEW PANELS RECONNECTING EXISTING CIRCUITS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70906	19041-10000-48833	120 S CARMELINA AVE	90049	11	132B141   584	4405042030	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.05702	-118.48042	INSTALLATION OF A NEW ESS (TESLA POWERWALL) & A NEW LOAD CENTER TO AN EXISTING PV1 SYSTEM.CONNECTED TO AN EXISTING 400Amp SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70907	10041-20000-04047	8612 W BURTON WAY	90048	5	138B169   715	4334016008	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Apartment			03/05/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.07189	-118.37986	Fire Alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70908	19041-10000-52027	619 S WESTLAKE AVE	90057	1	133-5A203 187	5141001900	C1-2	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM	03/21/2022 12:00:00 AM		Permit Finaled	02/22/2024 12:00:00 AM	ADDRESS	34.05839	-118.27416	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 2000A 120/208V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, NEW LIGHTS. TOTAL AFFECTED AREA IS 64,407 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70909	14041-20000-35309	4860 N MAMMOTH AVE	91423	4	168B157   233	2269023018	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.15937	-118.43232	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 5.28kW. Ungrounded system.22 EnPhase M250 microinverters with 22 280W pv modules across 2 strings (11).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70910	18041-20000-17696	11601 W WILSHIRE BLVD STE 400	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	Plan check for Title 24 Energy only in existing space T.I. office space. Total area: 3,575 sq ft.B#18016-10000-13114	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70911	16041-10001-10265	9321-9323 W PICO BLVD	90035	5	132A167   202	4330035013	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.05542	-118.39345	THIS IS PC FOR T24 ENERGY ONLY. CHANGES TO APPROVED SET OF PLANS TO USE 2008 ENERGY STANDARDS PER BUILDING PERMIT SUBMITTAL.Plan Check Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70912	19041-10000-42189	1421 S MAIN ST	90015	14	124-5A207 268	5133008004	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.03457	-118.26207	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24  ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70913	17041-10000-17107	13761 W WINGO ST	91331	6	195B153    13	2640004017	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.23506	-118.43312	PC for rooftop solar for new 6KW. Installing 25 solar modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70914	14041-10000-08110	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Ti , 14 th floor, title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70915	14041-10000-16672	5778 W OLYMPIC BLVD	90019	4	132B177   764	5085004036	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			06/20/2014 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM				Full plan check for power and lighting.  Total area = 11,346 sq. ft. (indoor) and 1,134 sq. ft. (outdoor, hardscape)New Electrical system for 12 unit apartment - 4 story + sub parking.  New construction.Fire alarm variance to be filed.  Building located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70916	17041-10000-45721	129 E G ST	90744	15	030B205   542	7423002029	[Q]C2-2D-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			12/20/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	33.77872	-118.26127	REPLACE INDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70917	13041-10000-09252	1068 N WESTERN AVE	90029	13	144B193   864	5536023016	[Q]C4-2D	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.09001	-118.30895	T.I. TO (E) MARKET/DELI (TAKE OUT ONLY) AREA OF WORK = 5,673;  NO INCREASE TO ALCOHOL SALES AREA;  EXTERIOR WALL & STOREFRONT UNDER SEPARATE  PERMIT.UPGRADE TO ELECTRICAL SERVICE TO SUPERMARKET. PC FOR POWER AND ENERGY. TOTAL AREA 10942 SQ FT. OUTDOOR AND SIGN LIGHTING NO GIVEN SPECIFIED AREA FOR oltg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70918	18041-20001-02539	6927 N REMMET AVE unit b	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			01/23/2018 12:00:00 AM			PC Approved	03/20/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	expeditepv2install roof mounted pv system sized 5kw interconnected with msp to unit B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70919	16041-10000-33205	2268 E 99TH PL 101-301	90002	15	093A217   272	6049019***	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Apartment			10/03/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	33.94695	-118.2321	PC for a power only for a New 3-story 15 unit apartment E4 Bldg 5-2 (Bldg. 4 of 8).  Scope includes a new 800A 120/208V 3 phase 4 wire service/distribution board. One plan is submitted for multiple apartment buildings. B#16010-10000-10000-02987	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70920	15041-10001-18359	10936 N ODESSA AVE	91344	12	210B137   763	2680009013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	34.2694	-118.49111	(((EXPEDITE FEES)))PV 1, ROOF MTD., SFD., 38 PANELS, 2 INVERTERS. TOTAL SYSTEM SIZE: 11KW AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70921	15041-20000-25313	14300 W TERRA BELLA ST	91402	6	198B153   657	2639028***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.41	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.23897	-118.44454	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70922	17041-10000-04424	2001 S SANTA FE AVE STE D	90021	14	120A217   241	5167012036	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.02106	-118.23039	PC for indoor Title 24. Removing HID fixtures and replacing them with new LED ones. Area: 1,950 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70923	18041-20000-23760	6516 W HOLLYWOOD BLVD	90028	13	148-5A187 181	5547016003	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.10142	-118.33167	Plan check for title 24 only in existing space, beauty salon new lighting and receptacle. Total area: 2053 sq ft. B#18016-20000-18411	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70924	16041-10001-33842	11698 W SAN VICENTE BLVD	90049	11	129B145    43	4265006072	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM			PC Approved	10/27/2016 12:00:00 AM	ADDRESS	34.05347	-118.46509	10/24/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include replacing/adding/relocating lighting fixtures, and revising title 24 calculations.Note: Original application is under PCIS#16041-10000-33842(((((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COFFE SHOP. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1100 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70925	17041-10000-04624	20165 W RINALDI ST BLDG S1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.27527	-118.57297	PC FOR POWER AND ENERGY FOR CORE AND SHELL BUILDING(S1). SCOPE INCLUDES A NEW 800A 277/480 V 3 PHASE 4 WIRE SERVICE, NEW PANELS, AND NEW EXTERIOR LIGHTS. TOTAL AFFECTED AREA IS 2756 SQ. FT. BUILDING # 16010-10000-06141	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70926	18041-10000-31601	1647 W CARSON ST	90501	15	051B193   904	7349033036	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	33.83164	-118.30807	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70927	17041-20000-03636	7869 N VAN NUYS BLVD	91402	6	189B149   464	2210022058	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.21384	-118.44905	New 6-story commerical building gymnasium and parking (3 levels fitness center with 3 levels parking).  Underground 3000A 208V 3ph-4w service.  176,784 sq ft.  Plan check for power and energy.  Electrical permit has been issued under 15041-10000-28641 under previous design (same engineer).  Full resubmittal due to extensive scope of work changes - from 2000A to 3000A service, complete system redesign.Building permit under 13010-10000-04552.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70928	15041-10000-23281	12800 W CULVER BLVD LKA35-KARF2	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	04/14/2016 12:00:00 AM	ADDRESS	33.98489	-118.42552	FUL PC, TI TO AN (E) OFFICE BUILDING, DIRECT TV. SCOPE OF WORK INCLUDES NEW PANELS AND LIGHTING, TOTAL CONNECTED LOAD > 400AMPS. TOTAL SQ. FT. 426. PC FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70929	12041-10000-25508	1539 S MIDVALE AVE	90024	5	129B153   149	4324025020	R1-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	ADDRESS	34.05257	-118.44085	PV1 11.45 KW SOLAR INSTALLATION .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70930	14041-10000-32803	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM			Not Ready to Issue	03/27/2015 12:00:00 AM	ADDRESS	34.01768	-118.42494	PC FOR ENERGY. NEW HVAC AND CHANGING SOME LIGHTS FOR GYMNASUM. TOTAL AREA 10972 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70931	17041-20000-29802	4734 N CEDROS AVE	91403	4	169-5A149 267	2265003032	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.15702	-118.45293	Plan check for a PV1 roof-mounted PV system. System size is 14.5 kWac and consists of (42) AC modules and (1) load center.$7.47 permit fee due to State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70932	17041-10000-23335	510 W 6TH ST STE 805	90014	14	129A209   101	5144004037	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	34.0482	-118.25464	PC FOR OFFICE T.I. TO COMBINE SUITE # 800, 802, 805, 810 AND 812 INTO ONE SUITE (SUITE# 805) IN A HIGH RISE BUILDING. TOTAL CONNECTED LOAD <400. TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS, RECEPTACLES AND EQUIPMENT. INCLUDING NEW PANELS.TOTAL AFFECTED AREA 6350 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70933	17041-10001-20732	6600 N TOPANGA CANYON BLVD 2096 C	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Supplemental PC for removal of track lighting. Changes clouded under delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70934	16041-10001-21734	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.93576	-118.3779	PC FOR ADDITIONAL 10 DEVICES ON THE ROOF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70935	12041-10003-14929	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.21585	-118.47965	"Revision to approved set (Refer to PCIS# 12041-10002-14929). (1)CHANGED FEEDER ""1"", ""1D"", ""2"", ""2D"", ""3"", ""4"", ""5"", AND ""6"" FROM 600MCM TO 500MCM    (2)Revise conductor size ""21"" and ""23"" from #8 to #6 AWG     (3)Add interlock interface from Supervisory PNL A to supervisory PNL B, and from ATS-3A to supervisory PNL A   (4) Revised Conduit schedule.   (5) Add 2 New Panels ""HTA"" and ""HTB"" with 2 New XFRMR 15 KVA each."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70936	12041-20000-20424	100 N SANTA FE AVE	90012	14	129A217    74	5173013016	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM			PC Info Complete	09/06/2012 12:00:00 AM	ADDRESS	34.04867	-118.23239	Upgrade existing service to 600 A, install 3 new panels, two to replace existing in same location, and reconnect existing circuit to the new panels.  No change in the lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70937	19041-10000-15055	4840 E ELDRED ST	90042	1	151-5A223 218	5471019034	RE11-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.108	-118.20895	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 18 MODULES (SUNPOWER SPR 305), POWER OPTIMIZERS ( SE P400) AND 1 CENTRAL INVERTER (SE3800A-US). SYSTEM SIZE IS 5.49KWdc AND 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70938	14041-20003-21783	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.21328	-118.45279	9.13.2017 - Plan check for changes to approved set. Update inverter output breaker sizes from 35A to 30A. Changes clouded on sheet PV-6.======08/31/2017 Changes to an approved set of plans. All changes have been clouded. PV interconnection has changed from line-side to load-side.08-02-16 Changes to an approved set of plans. Changes include remove PV carport from scope of work, as build layout of modules, change inverters from (6) 100kW to (18) 20kW and down size PV  system to 360kW. *****************Previouse Work Description***********************************$0 PERMIT FEE IS DUE TO SENATE BILL SB-1222.PV2 COMMERCIAL ROOFTOP. PLAN CHECK FOR FOR ROOF MOUNTED PV IN 2 LOCATIONS. ONE ON EXISTING BUILDING AND ANOTHER ON NEW PARKING CANOPY. ALL FALLS UNDER SAME PV SYSTEM. TOTAL SYSTEM SIZE 600KW AC USING 6 CENTRAL INVERTERS. TOTAL 664KW DC. CONNECTION TO 480V 1000A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70939	18041-20000-11459	3530 N VALLEY MEADOW ROAD	91403	5	159B141   126	2280013040	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.13463	-118.47571	Plan check for a PV1 roof-mounted PV system. System size is 13.35 kWac/14.32 kWdc and consists of (1) inverter, (44) modules, (1) load center, and (1) Tesal PowerWall.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70940	10041-20000-25159	1880 CENTURY PARK EAS #1114	90067	5	135B161    42	4319001001	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	02/04/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	T.I. to existing high rise building in rooms 1145 -1151 as shown on plans.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70941	19041-10000-47062	2917 W EXPOSITION PL BLDG #4	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Closed	06/18/2020 12:00:00 AM	ADDRESS	34.02047	-118.32806	NEW FIRE ALARM SYSTEM IN A NEW THREE-STORY, 5-UNIT APARTMENT BUILDING.  BLDG #4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70942	14041-20000-09845	7971 N MCNULTY AVE	91306	3	189B109   449	2108013010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.21514	-118.58575	PV1.  Install 3.75 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter standard plan: Power-One Aurora PV-3.0-OUTD.  (15) modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70943	14041-20000-27134	9701 N KESSLER AVE	91311	12	201B113   650	2761016030	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Expired	10/26/2016 12:00:00 AM	ADDRESS	34.24632	-118.56792	pv standard plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70944	18041-20000-40657	3206 N CANYON LAKE DR	90068	4	159B185   189	5577037001	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.12802	-118.32718	Plan check for a PV1 roof-mounted PV system. System size is 10.89 kWdc/9.81 kWac-CEC and consists of (33) micro-inverters, (33) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70945	15041-20000-04185	6322 N FALLBROOK AVE	91367	3	177B097    15	2039020012	(Q)C2-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM			PC Approved	02/17/2015 12:00:00 AM	ADDRESS	34.18527	-118.62312	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT. 1885 SQFT. EMERGENCY LIGHTING EXISTING TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70946	11041-10002-03982	1248 S FIGUEROA ST #101	90015	14	126A205    19	5138025014	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/08/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	34.04096	-118.2674	"Supplemental PLAN CHECK ONLY for ENERGY.  Change to general lighting only from previously approved plans.<<<<TI  RESTAURANT,  4499 SF  CONSTRUCT  15'0"" X 9' 0""  ( 139 SQ FT )   MEZZANINE>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70947	19041-10000-51265	11229 N CARRILO DR	91345	7	210B145   526	2664007***	P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	08/27/2020 12:00:00 AM	ADDRESS	34.27445	-118.46864	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF CENTRAL INVERTER(SE3800H-US) WITH 13 MODULES USING P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70948	19041-10000-01494	2451 N SUMMITRIDGE DR	90210	5	153B157    32	4384005026	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM			Reviewed by Supervisor	01/23/2019 12:00:00 AM	ADDRESS	34.11848	-118.42278	FULL PLAN CHECK FOR NEW S.F.D WITH ATTACHED GARAGE. SCOPE OF WORK INCLUDES NEW 1200AMPS SERVICE,120/208 3PH, CIRCUITS EQUIPMENTS AND LIGHTIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70949	16041-10000-02083	8009 W MELROSE AVE	90046	5	141B177   550	5527014030	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	ADDRESS	34.08391	-118.36419	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 3468.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70950	19041-10000-07159	8600 N HAZELTINE AVE	91402	6	195B153  1016	2638015900	OS-1XL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.22674	-118.44129	REMOVE HID FIXRTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70951	15041-30000-42254	5128 N BLUEBELL AVE	91607	2	171B161   692	2357002010	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Expired	02/01/2018 12:00:00 AM	ADDRESS	34.16372	-118.41036	Addition of new roof mounted solar PV array to existing roof mounted solar PV system on existing single family dwelling.  Total system size = 13.2 kWac (6 kWac new).  Addition of one inverter to existing two inverter system (three inverters total).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70952	10041-10000-19319	7800 W BEVERLY BLVD	90036	4	138B177   455	5512001003	C2-1-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Expired	12/19/2012 12:00:00 AM	ADDRESS	34.07594	-118.35916	INSTALLATIONS OF 7 POLE-SUPPORTED PARKING LUMINAIRES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70953	18041-20000-29974	8769 N LURLINE AVE	91306	3	195B109   155	2780029002	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.2302	-118.5843	Plan check for a PV1 roof-mounted PV system. System size is 4.93 kWdc/6 kWac and consists of (1) inverter and (17) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70954	12041-10000-23998	22833 W ELKWOOD ST	91304	3	189B097   818	2014010005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	10/30/2012 12:00:00 AM	ADDRESS	34.2127	-118.62482	8.64 roof mounted PV for a single family.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70955	19041-20000-07686	8717 N WOODMAN AVE UNIT A	91331	6	195B153  1033	2637004033	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	06/20/2022 12:00:00 AM	ADDRESS	34.22825	-118.43505	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70956	19041-10000-11494	1999 S BUNDY DR P-1 & P-2	90025	11	123B149   406	4259019007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Issued	04/12/2019 12:00:00 AM	ADDRESS	34.03406	-118.45593	T-24 energy only, plan check for an interior tenant improvement of elevator lobbies on levels p-1 and p-2. Scope includes new lighting and controls. taotal affected area is 1836 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70957	19041-10000-09522	904 N SYCAMORE AVE	90038	4	144B181   803	5532010041	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.08737	-118.34265	T-24 ONLY, CHANGE OF USE FROM (E) OFFICE TO RESTAURANT W/TI NEW PARTITIONS. SCOPE OF WORK INCLUDES ONE NEW PANEL,  NEW CIRCUITS AND LIGHTING. TOTAL SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70958	17041-20000-45990	3876 W FRANKLIN AVE	90027	4	150B201  1404	5433012004	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.10363	-118.27665	INSTALLATION OF ENERGY STORAGE SYSTEM 13.5 KWH.  PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM 7.5 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70959	16041-10000-44708	6344 N TOPANGA CANYON BLVD #2040	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.18628	-118.60544	Plan check for 1st time tenant Medical office UCLA Health. Total area: 791 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70960	15041-10000-28975	751 S SPRING ST	90014	14	127-5A211 157	5144015018	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			09/18/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Closed	01/07/2019 12:00:00 AM	ADDRESS	34.04345	-118.25354	NEW 24-STORY MIXED USE BUILDING (282 UNITS FROM LEVEL 6 TO LEVEL 24, OVER 5-STORY PARKING AND 4-LEVEL OF SUBTERRANEAN PARKING, WITH RETAIL ON GROUND FLOOR)PLAN CHK FEE COUNT SUBMITTED BY APPLICANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70961	11041-10003-10748	1900 S SEPULVEDA BLVD	90025	5	126B153   181	4323022031	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/06/2012 12:00:00 AM	04/06/2012 12:00:00 AM		Permit Finaled	02/13/2013 12:00:00 AM	ADDRESS	34.04447	-118.4413	Brand New Fire Alarm System in an existing shell building for Animanl Hospital.  3 stories tall with 3 story parking garage.  Everything is new.   Fire Alarm has been seperated from Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70962	17041-10004-20044	10011 W CHEVIOT DR	90064	5	123B165   225	4316015006	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM			PC Approved	02/06/2019 12:00:00 AM	ADDRESS	34.03578	-118.40305	Change to an approved set by adding a new 90-Amp disconnect for the load center. All changes under delta-4 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70963	18041-10001-31409	230 N GAFFEY ST	90731	15	018B197   803	7448031031	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM			PC Approved	11/30/2018 12:00:00 AM	ADDRESS	33.74479	-118.29212	*Fee expedited per applicant**Install Rofftop solar system (PV2) on (E) commercial building. System size: 12 kW DC / 10.75 kW AC. (50) modules with Enphase IQ6, and (1) 100 A combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70964	12041-10001-11756	7511 S DUNBARTON AVE	90045	11	102B161   210	4110026009	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2012 12:00:00 AM			PC Approved	10/09/2012 12:00:00 AM	ADDRESS	33.97242	-118.41036	Revision to the approved plan. Plan was revised base on the Engineer report.  According to the Eng. report, the job is located in the methane buffer zone with Methane cencentration < 0.5 ppmv and Methane pressure < 0.01 inches of water column.  (((((((((New 6kw, rooftop, photovoltaic system for an existing sfr.  System uses Solar Edge DC-DC converters.  Permit for Misc is for Solar Edge converters.  System is in a methane zone and will comply with requirements for Methane zone level V. )))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70965	18041-20001-40151	8742 N RANCHITO AVE	91402	6	195B153   899	2637001017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Issued	01/09/2019 12:00:00 AM	ADDRESS	34.22894	-118.43894	Revision to approved set and change of work description: PV1.  Install 10.15 kW DC roof mounted and grid tied PV system.  (35) modules with 10 kW rated string inverter.  $0 plan check and permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((pv1install roof mounted pv system sized 10KW AC interconnected with msp.  system size 11.02KW DC)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70966	19041-10000-53362	6250 N TOPANGA CANYON BLVD STE 1585	91367	3	180B105    60	2146029022	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	01/07/2021 12:00:00 AM		Issued	01/07/2021 12:00:00 AM	ADDRESS	34.18498	-118.60554	FULL PC FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES 3 NEW PANELS., NEW CIRCUITS, NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA: 3533 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70967	16041-20000-45110	1280 N STONE CANYON ROAD	90077	5	147B149   424	4370018014	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2016 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	06/16/2021 12:00:00 AM	ADDRESS	34.09754	-118.44975	Plan check for power only. Project site is an existing single-family home. Project scope is a new electrical service, distribution system, and loads.Note: Building application has been generated under 16014-10000-03225	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70968	12041-10000-02457	18242 W BERMUDA ST	91326	12	207B125   180	2715010018	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2012 12:00:00 AM			Reviewed by Supervisor	02/24/2012 12:00:00 AM	ADDRESS	34.2661	-118.53119	11.28KW roof mounted photovoltaic system for single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70969	11041-10000-09200	1030 W PACIFIC COAST HWY 1ST FLR	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.20	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM	01/30/2012 12:00:00 AM		Permit Finaled	06/14/2012 12:00:00 AM	ADDRESS	33.79073	-118.29408	EXISTING OFFICE BUILDING.  REMODEL OF FIRST FLOOR.  CONVERTING EXISTING STACK STORAGE INTO OFFICE SPACE.  TITEL 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70970	18041-20000-48484	9326 W HAZEN DR	90210	4	153B165   361	4388019022	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2018 12:00:00 AM			PC Info Complete	01/05/2021 12:00:00 AM	ADDRESS	34.11394	-118.39715	Plan check for power only 600 amp service.Note: Building applications have been generated under 15010-30000-03339 (SFD) and 15010-30000-03340 (accessory living quarters). Electrical permit fees have been paid for in the building combo permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70971	18041-20000-32466	13661 N BADGER AVE	91342	7	228B157   704	2511021019	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.32018	-118.41985	PV1.  Install roof mounted PV system sized 7.6 kW AC interconnected with MSP.  Energy storage system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
70972	19041-10001-44064	18814 W FAIRFIELD ROAD	91326	12	207B121   673	2728031027	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM			PC Info Complete	11/27/2019 12:00:00 AM	ADDRESS	34.26173	-118.54358	"Delta ""1"" changes to the approved plans for changing the short circuit rating of the equipment from 22KAIC to 10KAIC on a 200Amp Service in a single family home.<<<<(E-PLAN) NEW ROOF-MOUNTED PV1 INSTALLATION WITH AN EXISTING200 AMPS SERVICE. INSTALLATION INCLUDES 39 MODULES (LG350N1C-V5), 39 MICROINVERTERS (Enphase IQ), AND  1 COMBINER BOX. SYSTEM SIZE: 13.65 KW DC; 9.36 KW AC *NOTE: MAIN BREAKER DERATING WILL BE ON SEPARATE PERMIT>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70973	14041-10000-28084	899 S FRANCISCO ST	90017	14	129A207   155	5144023054	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.04731	-118.2643	5,000 amp temp power for new hotel buildings with temp distribution equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70974	18041-20000-36331	20816 W SPRUCE CIR	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.29507	-118.58796	PV1.  Install 4.06 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70975	19041-20000-40318	10720 W CHALON ROAD	90077	5	141B149   146	4362003035	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Issued	11/20/2019 12:00:00 AM	ADDRESS	34.08291	-118.44997	New 800 amp 3 phase 120/208v service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70976	10041-20000-24797	1100 N MORAGA DR	90049	5	141B145    47	4368002004	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2010 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	06/23/2011 12:00:00 AM	ADDRESS	34.08593	-118.46973	PLAN CHECK 15.62 KW ROOF-MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70977	18041-20000-45133	20447 W NORDHOFF ST	91311	12	195B109    60	2781001037	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	06/16/2020 12:00:00 AM		Issued	06/16/2020 12:00:00 AM	ADDRESS	34.232	-118.57917	3000A 480Y/277V service upgrade to (E) commercial facility.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70978	15041-20000-23045	10390 W SANTA MONICA BLVD #400	90025	5	132B157   653	4319009093	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM	07/20/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.05734	-118.42365	TI TO OFFICE SPACE. NEW LIGHTING. NEW PLUGS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70979	10041-20000-03607	19950 W RINALDI ST #101	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	03/24/2010 12:00:00 AM		Permit Finaled	06/23/2010 12:00:00 AM	ADDRESS	34.27535	-118.56939	T. I. IN  MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70980	18041-10000-47905	6075 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	03/21/2019 12:00:00 AM		Permit Finaled	04/20/2020 12:00:00 AM	ADDRESS	33.94479	-118.38915	CORE AND SHELL FOR A SERVICE MAINTENANCE FOR UNITED AIR LINES (UNITED MAINTENANCE HANGER) SERVICE ENTRANCE ONLY. SIZE OF THE SERVICE 800A, @ 4160V, 3PH. SCOPE INCLUDES FEEDING 2 SUBSTATIONS 150A AND 100A. AND 2 UNTIED HANGERS T-1 AND T-2 400A EACH. 2 STATIONS AND 2 HANGERS ARE FOR FUTURE WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70981	17041-20000-21769	6420 W WILSHIRE BLVD Suite 1905	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/28/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for energy only. TI to existing office suite 1905 in high rise building. New lighting (incl. emergency) - 1,230sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70982	15041-20000-18874	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM			PC Approved	06/17/2015 12:00:00 AM	ADDRESS	34.07457	-118.37864	Plan check for parking structure level B1, B2, B3, P1, P2 Title 24 only. Total affected area: 9,200SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70983	13041-10001-17015	11024 W STRATHMORE DR	90024	5	135B149   462	4363016001	[Q]R4-1VL-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Apartment			02/26/2014 12:00:00 AM			PC Approved	04/04/2014 12:00:00 AM	ADDRESS	34.06471	-118.45062	CHANGES TO APPROVED SET OF PLANS. CHANGES HAVE BEEN CLOUDED. A SHEET HAS BEEN INCLUDED WITH ALL THE CHANGES.PLAN CHECK POWER AND ENERGY FOR NEW 31 UNIT APARTMENT BUILDING WITH SUBTERRANEAN PARKING. New 31 unit 5-story Type IIIA apartment over 2 levels of Type IA parking garage. 2 units out of 31 units are very low income.Fire alarm variance filed 8/13/2013 - MT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70984	17041-10000-06649	5353 W IMPERIAL HWY STE 506	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	33.93112	-118.37375	PC FOR ENERGY T24 ONLY. COMMERCIAL BUILDING.  REPLACING 21 HID LIGHT FIXTURES WITH NEW LED LIGHTS. TOTAL AREA 15450 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70985	16041-10000-24116	6511 N DENNY AVE	91606	2	180B177   166	2414032039	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.18886	-118.36499	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(23)MODULES-LG ELECTRONICS LG310N1C-G4(1)INVERTER-SOLAREDGE SE6000	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70986	15041-10000-36577	777 S SANTA FE AVE TOWER	90021	14	124-5A217 270	5166013009	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.03354	-118.23024	Installation of new fire alarm system in Ford Factory.  This is for TOWER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70987	17041-10000-24791	100 WORLD WAY SPACE 168	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM			Corrections Issued	07/21/2017 12:00:00 AM	ADDRESS	33.94572	-118.40095	PC FOR FIRST TIME TI. PC FOR POWER AND ENERGY. NEW KIOSK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70988	19041-10000-00953	12121 W WILSHIRE BLVD STE 910	90025	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Issued	02/21/2019 12:00:00 AM	ADDRESS	34.04386	-118.46816	T-24 PLANCHECK FOT A TI IN EXISTING OFFICE SPACE. SCOPE INCLUDES 2 NEW 100A PANELS, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 520SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70989	13041-10001-05508	110 N GEORGE BURNS ROAD	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.07564	-118.38149	Delta-5 revisions to approved set.  Change of upstream connecting switchboard for emergency distribution board EDPA.  ATS now existing to remain.  Change of air handling unit rating.  Small modifications to Title-24 energy calculations.  (((In the Schuman Building, renovate and convert existing basement  space to equipment storage room with freezers. Aan emergency feeder and an normal feeder from an existing EMswitchboard board in the Davis Building  are used to supply the equipment in the basement of  the schuman building.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70990	17041-10000-08185	10250 W SANTA MONICA BLVD #1937	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR FIRST TIME TI ""JOHN HARDY""  IN WESTFIELD CENTURY CITY. SUITE 1937"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
70991	18041-10000-03635	5611 N FIGUEROA ST Suite 1	90042	1	151-5A229 262	5468033019	[Q]C4-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.10	Electrical	Electrical	Commercial			01/31/2018 12:00:00 AM			PC Approved	01/31/2018 12:00:00 AM	ADDRESS	34.10937	-118.19392	PC ONLY FOR RESTAURANT TI FOR TITLE 24 ENERGY ONLY. TOTAL CONNECTED LOAD <400ATOTAL AFFECTED AREA 2288 SQ.FT SCOPE INCLUDES NEW PANELS CIRCUITS LIGHTS AND EQUIPMENT.PC FOR LOST SET OF PLANS PERMIT HAS BEEN PAID FOR UNDER APPLICATION # 17041-10000-27897 / E17LA03607 B#16016-10000-30146	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70992	13041-10000-11884	1716 S LA CIENEGA BLVD	90035	10	129B173  1364	5066006029	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	11/14/2013 12:00:00 AM	ADDRESS	34.04654	-118.37607	POWER PLAN CHECK ONLY FOR 600A EQUIPMENT. NEW SERVICE AND SERVICE EQUIPMENT 600A, AND ONE NEW PANEL 225 PANEL. 34K AVAILABLE FAULT CURRENT, EXISTING PANELS MAY NOT BE RATED FOR THE AVAILABLE FAULT CURRENT. TITLE 24 IS APPROVED UNDER APPLICATION 12041-20000-14700. PLANS TO BE MODIFIED TO SHOW PANELS D, C, B AND A  AS EXISTING PER CONTRACTOR. FEEDERS FOR PANEL D, C, B, AND A ARE NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70993	13041-10000-10304	380 WORLD WAY Space T51	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	pc for power and energy. TI TO #T51A-NG (HUDSON). less than 400A. new panel 21 branch circuits	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70994	17041-20000-33702	6859 N SHOSHONE AVE	91406	6	183B129   842	2229002011	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.19555	-118.51646	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (32) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
70995	14041-10000-28637	15121 S FIGUEROA ST	90248	15	072B201    88	6120028003	[Q]CM-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	33.89427	-118.28334	Title 24 plan check only.  Total area = 11,630 sq. ft.T.I. to existing book store.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70996	17041-10000-23530	1210 S SOTO ST	90023	14	121-5A221 102	5170018018	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.10	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.02759	-118.21931	PC FOR A TI TO AN EXISTING MCDONALDS FOR TITLE 24 ENRGY ONLY. INSTALLING NEW PANELS CIRCUITS LIGHTS AND EQUIPMENT.TOTAL AFFECTED AREA 5889 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70997	18041-10000-00194	642 N STANLEY AVE	90036	5	141B177   701	5526015023	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.08309	-118.35622	Plan check for new storage battery system 13.5kWH. in SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
70998	18041-10000-07060	8453 N RESEDA BLVD	91324	12	192B125   316	2785018017	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Issued	02/27/2018 12:00:00 AM	ADDRESS	34.22419	-118.5363	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL  AFFECTED AREA IS 12600 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
70999	17041-20002-22681	13478 W EGBERT ST	91342	7	228B157    60	2503016011	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM			PC Approved	07/28/2017 12:00:00 AM	ADDRESS	34.32548	-118.42682	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71000	13041-10001-36289	17736 W SAN FERNANDO MISSION BLVD	91344	12	210B129   346	2712002004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.27197	-118.52094	Expedited RSES plan check per applicant request.{{PV1, Install 5 kW DC roof-mounted solar array for a one story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (20) Modules: Trina Solar TSM-250PA05.18.(20) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71001	10041-20000-11169	1241 N VINE ST	90038	13	144B185   204	5533005001	C2-1D, RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			06/11/2010 12:00:00 AM	06/11/2010 12:00:00 AM		Permit Finaled	04/11/2011 12:00:00 AM	ADDRESS	34.09373	-118.32682	PLAN CHECK ENERGY TITLE 24 AND EMERGENCY LIGHTING, NO HIGH RISE , CHANGE OF USE FROM RETAIL TO COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71002	15041-20000-21197	10570 W ART ST	91040	7	201B177   192	2542018021	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	34.24845	-118.36018	$0 permit fee due to senate bill 1222 from 2012Installation of new roof mounted solar PV array.  Total system size = 13.5 kWac.  Two inverter system.  One inverter is connected so existing subpanel and one is connected to new main panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71003	10041-20000-22090	5730 N CAHUENGA BLVD	91601	4	174B177   193	2415028001	C2-1VL, [Q]C2-1XL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	04/25/2011 12:00:00 AM	ADDRESS	34.17486	-118.3614	New roof mounted 16.65KW photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71004	18041-10002-05928	7913 S KENTWOOD AVE	90045	11	099B165   197	4109018017	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM			Reviewed by Supervisor	03/05/2018 12:00:00 AM	ADDRESS	33.9703	-118.40209	SUPPLIMENTAL FOR THE ENERGY STORAGE SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71005	14041-20000-28351	3822 S DUNSMUIR AVE	90008	10	117B177    94	5029008011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM	10/17/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.01755	-118.363	PV1 SFD. TOTAL SYSTEM SIZE 5.16KW AC USING 24 MODULES. USING MICROINVERTER SYSTEM WITH ENPHASE M215.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71006	18041-10000-20385	740 W MARTIN LUTHER KING, JR BLVD	90037	9	115-5A201 101	5019025063	(T)(Q)C2-2	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.01093	-118.28686	INSTALLATION OF NEW FIRE ALARM SYSTEM. 1 FACP, 2RPS,  272 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71007	19041-20000-40378	18452 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71008	16041-10000-44022	4550 N VAN NUYS BLVD #F	91403	4	168A151   171	2265013019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.15445	-118.4485	PC FOR ENERGY. CHANGE OF USE FROM RETAIL TO BEAUTY SALON.  CONNECTED LOAD <400 A. TOTAL AREA 1289 SQ FT. B # 16016-10000-18764	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71009	19041-10000-33691	7040 N SEPULVEDA BLVD	91405	6	183B145  1121	2220022010	C1.5-1VL, C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	10/21/2020 12:00:00 AM		Permit Finaled	05/27/2021 12:00:00 AM	ADDRESS	34.19889	-118.46596	FULL PC FOR CONSTRUCTION OF A NEW GROUND-UP STARBUCKS SCOPE INCLUDES A NEW  SERVICE SIZE OF 600A,120/208V,4W,3PH. AREA OF SCOPE 19,422 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71010	17041-10001-23334	11401 N PORTER RANCH DR BLDG 4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	06/30/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY.  BLDG 4 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 41 unit apartment with 1600 amp 208 volt service.       Building 4 of 10.  Type IV.       Building permit #17010-10000-02381	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71011	14041-20000-17362	810 S FLOWER ST 13TH FLOOR	90017	14	129A209   164	5144020040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Closed	06/12/2019 12:00:00 AM	ADDRESS	34.04692	-118.26018	PLAN CHECK FOR TENANT IMPROVEMENT EXISTING COMMERCIAL HIGH RISE BUILDING.  POWER AND ENERGY ON THE THIRTEEN FLOOR.  LOADS SHOWN ON PANELS ARE DESIGN ONLY FOR FUTURE REFERENCE.  NOT CHARGED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71012	16041-20000-32988	6816 N BELLINGHAM AVE	91605	2	183B165   600	2321026001	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.19456	-118.39857	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.73 KW$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71013	16041-30002-12160	9039 N WHITAKER AVE	91343	12	195B133    16	2688025032	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM			Reviewed by Supervisor	04/19/2016 12:00:00 AM	ADDRESS	34.23501	-118.49925	Supplemental application for expedite fees only.    Installation of new roof mounted solar PV array on existing single family dwelling.   Total system size = 10 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71014	10041-10000-25331	1744 S GRANVILLE AVE	90025	11	126B149   954	4262016023	[Q]R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.01	Electrical	Electrical	Commercial			12/21/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	05/03/2011 12:00:00 AM	ADDRESS	34.03927	-118.4549	New Fire Alarm system. EPC is for Power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71015	12041-20000-16377	1800 N HIGHLAND AVE	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.10436	-118.33763	T.I. to a high rise building on the 4th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71016	16041-10001-29461	922 E E ST	90744	15	030B209   812	7424017043	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			01/24/2018 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	33.77595	-118.25106	01-24-2018 Changes to an approved set of plan. Changes include location of service equipment and configuation of service equipment layout. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71017	18041-10000-17847	6642 N RESEDA BLVD	91335	3	180B125   306	2125013008	[Q]C2-1VL-CDO-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.19107	-118.53583	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71018	14041-20000-17640	5000 S MAIN ST	90011	9	111A205   300	5109004053	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2293.00	Electrical	Electrical	Apartment			06/30/2014 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	PIN	33.99720157	-118.27357014	New 4-story 59-unit apartment building.  Power and energy.  Fees adjusted to meet applicant check amount.  Verify ckt counts and SFD smoke detectors to be added to plan check fee.  Variance to separate fire alarm plans to be filed before permit issuance.NOTE: CRA CLERNACE WAS OBTAINED DURING BUILDING APPROVAL, THIS NEW CONSTRUCTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71019	13041-10000-32688	705 N HENRY FORD AVE	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			Verifications in Progress	12/12/2013 12:00:00 AM	ADDRESS	33.77995	-118.24199	PLAN CHECK FOR A METHANE MITIGATION SYSTEM IN THE PORT OF LOS ANGELES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71020	13041-10000-20904	3500 S MAIN ST	90011	9	118-5A205 273	5120008001	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM	08/29/2013 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	PIN	34.01756434	-118.27290944	TITLE 24 WORK PERTAINING TO STORAGE ROOM; REMOVING EXISTING FIXTURES AND REPLACING WITH NEW LIGHTING FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71021	17041-10001-39126	16749 W BOLLINGER DR	90272		129B121   938	4415008006							Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM			PC Approved	01/10/2018 12:00:00 AM	ADDRESS	34.04608	-118.54474	*Fee expedited per applicantInstall New PV1 rooftop solar system on a SFD. 5kW AC, (16) modules, (1) inverter, and (1) ESS Tesla Powerwall, and 1 load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71022	14041-10000-16797	12746 W JEFFERSON BLVD ste 1120	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR POWER AND ENERGY. TI FOR A  NEW RESTURANT hopdoddy.TOTAL AREA 5007 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71023	19041-10001-14358	13326 N PASHA PL	91342	7	225B157   458	2512022036	R1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM			PC Approved	05/09/2019 12:00:00 AM	ADDRESS	34.3135	-118.41991	EXPEDITED.PV1 NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 11400H INVERTER, (1) 6000H INVERTER, AND (53) MODULES + OPTIMIZERS. TOTAL SYSTEM SIZE IS 17.4KWAC AND 19.06 KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71024	13041-10000-34431	1243 S OLIVE ST	90015	14	126A207   200	5139023900	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			12/12/2013 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.03859	-118.26331	POWER AND ENERGY PLAN CHECK FOR for New 7 Story (5 Story Type III-A over 2 Story Type IA Podium) Mixed Use Building w/293 Unit Apartment & Retail Building. Located in methane zone.ASSOCIATED BUILDING PERMIT: 13010-10001-02722	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71025	18041-10000-44554	12629 W MERCER ST	91331	7	213B161   660	2532019023	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.27922	-118.4087	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 10 MODULES (Q-PEAK 315) , 10 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.15KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71026	16041-10000-28084	601 W 5TH ST	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM			PC Approved	08/09/2016 12:00:00 AM	ADDRESS	34.05049	-118.25386	PC for title 24 energy only. Total are is 1636 sq.ftScope of work includes lights only.located on the 6th floor common area\ restroom.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71027	17041-10000-11433	15533 W EL CAJON ST	91342	7	222B145   235	2604013020	RA-1-K	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/07/2017 12:00:00 AM	ADDRESS	34.30372	-118.47036	PV SYSTEM. TOTAL OF 24 MODULES AND CENTRAL INVERTER 7KW AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71028	14041-10000-15184	3018 W ANGUS ST	90039	4	150A205    98	5432012004	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.10637	-118.27056	PV1. ROOF MOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 6.21 DC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71029	10041-20000-13598	13017-13019 W VENTURA BLVD	91604	5	165B161   958	2375020028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	09/13/2010 12:00:00 AM	ADDRESS	34.14577	-118.41665	Plan check T-24 Energy (general/emergency) lighting for hair salon.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71030	11041-20000-01458	10823 N ZELZAH AVE Bld. A3 &-A4	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM			PC Info Complete	01/25/2011 12:00:00 AM	ADDRESS	34.2668	-118.52366	Install outdoor lighting.  Plan check for energy only.NOTE:  Permit is under 11041-20000-01457	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71031	11041-10000-20718	9301 N TAMPA AVE #29B	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM	10/26/2011 12:00:00 AM		Permit Finaled	12/02/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	T.I. for a retail (shoe store).  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71032	19041-20001-27675	8150 N ORION AVE	91406	6	192B145   617	2654038014	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM			PC Approved	08/02/2019 12:00:00 AM	ADDRESS	34.2189	-118.47197	Recheck for lost set of plans	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71033	18041-20000-42865	444 S SAN VICENTE BLVD 9th Floor	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.07021	-118.37547	Plan check for Title 24 only. Project scope is a tenant improvement to an existing suite in a commercial building on the 9th floor. Total lighting area = 485 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71034	15041-10000-02874	2789 W OLYMPIC BLVD 101-106	90006	10	129B197   186	5078007030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM			PC Info Complete	08/03/2015 12:00:00 AM	ADDRESS	34.0529	-118.29436	PLAN CHECK FOR POWER AND ENERGY FOR NEW 3 STORY BUILDING. NEW 2000AMP SERVICE. FULL TI HAS BEEN DONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71035	18041-20000-39502	22726 W MARLIN PL	91307	12	183B097   527	2024027020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	PIN	34.19662218	-118.62207619	Plan check for PV roof mounted system, system size:  5.10kW DC, 5.0kW AC with 17 PV Modules and 1 inverter(5.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71036	13041-20000-28582	18900 W WILLARD ST	91335	12	192B121   968	2104036023	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.21876	-118.54514	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. 2 STRINGS/INVERTER. TOTAL OF 29 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71037	15041-20000-20622	19566 W VENTURA BLVD	91356	3	174B117   324	2164016027	C2-1VLD, P-1VLD	South Valley	Encino - Tarzana	Tarzana	YES	1394.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	PIN	34.17217845	-118.55930747	Plan check Title 24 only for Beauty Salon. Existing branch circuits. Total indoor lighting area: 1,066 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71038	18041-10000-43642	8564 S BROADWAY	90003	9	097-5A203 327	6040010015	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	33.9604	-118.27809	PLAN CHECK FOR ENERGY ONLY. REMODEL EXISTING BANK ATMS, ATM ROOM AND REPLACE CANOPY OVER ATM AREA. SCOPE OF WORK INCLUDES NEW OUTDOOR ATM LIGHTING TO AN EXISTING CIRCUIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71039	18041-10000-42445	1484 S MATEO ST	90021	14	121-5A217 458	5167001***		Central	CENTRAL CITY NORTH			2060.31	Electrical	Electrical	Commercial			11/06/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Issued	11/14/2018 12:00:00 AM	ADDRESS	34.02753	-118.23196	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71040	17041-10000-18441	16161 W RAYMER ST	91406	6	189B141    17	2205029011	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.21803	-118.48533	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71041	16041-20000-37739	5207 N ZELZAH AVE	91316	5	171B129   174	2162007069	R3-1	South Valley	Encino - Tarzana	Encino		1395.03	Electrical	Electrical	Apartment			10/25/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Issued	11/01/2016 12:00:00 AM	ADDRESS	34.16559	-118.52221	pv2install roof mounted pv system sized 9.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71042	15041-10000-38643	8601 S LINCOLN BLVD UNIT 130	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	33.95939	-118.41943	T-24, TI TO AN (E) COMMERCIAL BUILDING. SCOPE INCLUDES TWO NEW OFFICES WITH NEW LIGHTS AND RECEPTACLES. TOTAL SQ. FT. 220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71043	19041-20002-03472	22729 W GAULT ST	91307	12	183B097   226	2024019011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Issued	02/19/2019 12:00:00 AM	ADDRESS	34.19925	-118.62178	Addition of 9.8 kWh energy storage system and Generac backup panel to project scope.(((PV1.  Install 7.59 kW DC / 7.6 kW AC roof mounted grid tied PV system.  (23) modules with 7.6 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71044	11041-20000-27585	3470 S TROUSDALE PKWY	90089	8	120A201    75	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/29/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Issued	12/29/2011 12:00:00 AM	ADDRESS	34.02202	-118.28393	Existing fire alarm.  Adding a new remote power panel, 4 strobes, and 4 horn/strobes on the 3rd and 4th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71045	17041-10000-41199	2235 E 7TH ST	90023	14	124-5A219 229	5171020045	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.03468	-118.22391	PC FOR POWER ONLY. SCOPE INCLUDES UPGRADING SERVICE TO 2500A 480/277V 3 PHASE 4 WIRE SERVICE/DISRIBUTION BOARD, AND REFEEDING EXISTING ELECTRICAL EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71046	14041-10000-03665	930 S SANTEE ST #5	90015	14	126A209   172	5145016048	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	02/10/2014 12:00:00 AM		Permit Finaled	02/25/2014 12:00:00 AM	ADDRESS	34.03934	-118.25414	TI in an existing retail. Replace existing fixture with fluoresent. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71047	13041-10000-08177	333 S SPRING ST	90013	14	130-5A211 168	5149019035	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/29/2013 12:00:00 AM			PC Approved	04/26/2013 12:00:00 AM	ADDRESS	34.04956	-118.24793	T24 for a change of use renovation from an office to a veterinary clinic.  Permit already pulled, sent back by inspector, under 13041-90000-00833	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71048	18041-10000-14744	1001 W KNOX ST	90502	15	057B197    18	7351031017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/23/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	33.85434	-118.29392	NEW FIRE ALARM SYSTEM ON (E) 2 STORY BUILDING, INSTALL (1) PANEL, (204) DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71049	19041-10000-25110	7651 N WOODMAN AVE	91402	6	186B157    25	2214019020	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.20984	-118.43126	Energy plan check for removing HID fixture and replace with new LED fixture for in/outdoor lighting with a total area of 39825-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71050	16041-20000-19112	18130 W CALVERT ST	91335	3	177B125   557	2124015031	(T)R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.18173	-118.52812	PERMIT FEE $0.00 BY STATE SENATE BILL N0. 1222PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 14KW INTERCONNECTED WITH MSP.(48) LG MODULES(2) SMA 7000 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71051	19041-10000-26388	9009 N CANOGA AVE STE A	91304	3	195B105    39	2779018039	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Issued	07/11/2019 12:00:00 AM	ADDRESS	34.23398	-118.59778	Remove HID fixtures and replace with new LED fixtures (Indoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71052	13041-10000-20437	245 S MAIN ST	90291	11	111B141   545	4286017***	(Q)C4-2D	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			07/31/2013 12:00:00 AM			PC Approved	08/12/2013 12:00:00 AM	ADDRESS	33.99681	-118.47872	TENANT IMPROVEMENT ON RESTAURANT.  WORK ON THE FIRST FLOOR.  TITLE 24 PLAN CHECK ONLY. 84 OCCUPANTS PER BUILDING APPLICATION 13016-10000-10498. PERMIT TO BE PULLED AT THE ELECTRICAL PLAN CHECK COUNTER. EMERGENCY LIGHTING. INDOOR AND OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71053	16041-20000-20464	14748 W KESWICK ST	91405	6	186B149    26	2210028008	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	03/01/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.21015	-118.45472	New service and build out for (E) plant cultivation building in response to code enforcement action.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71054	19041-10000-38697	6360 W 3RD ST	90036	4	138B177   796	5509018009	C2-1-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM			PC Info Complete	10/28/2019 12:00:00 AM	ADDRESS	34.07122	-118.36074	T-24 PLAN CHECK FOR A TI. SCOPE INCLUDES NEW TRACK LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 13,810 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71055	14041-20000-22033	925 W WEST 35TH ST	90089	9	120A201    44	5039012030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	34.02328	-118.28725	USC Norris Dental Science Center remodel of restrooms on 2nd and 4th floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71056	14041-10000-17428	1925 S CENTURY PARK EAST	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.06066	-118.41426	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES  ON THE 23RD FLOOR. 2305 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71057	18041-10000-15015	21431 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Issued	06/12/2018 12:00:00 AM	ADDRESS	34.25739	-118.59841	RALPH'S TI. FULL PLAN CHECK FOR POWER AND ENERGY. SERVICE UPGRADE TO 2000 AMPS.  RECONNECTING TO EXISTING FEEDERS AND EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71058	11041-20000-22921	555 W 5TH ST 18th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/26/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	T.I.  Remodel 18th floor of a high rise ofice building.  Plan check is for energy/emergency only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71059	11041-20000-17889	11601 W WILSHIRE BLVD suite#1925	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/23/2011 12:00:00 AM	08/23/2011 12:00:00 AM		Permit Finaled	10/14/2011 12:00:00 AM	PIN	34.0509267	-118.45996763	TI in an existing office BLDG. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71060	13041-20000-34336	141 E JEFFERSON BLVD	90011	9	118-5A205 233	5120005003	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM			PC Approved	12/17/2013 12:00:00 AM	ADDRESS	34.01806	-118.27095	T24 FOR EXISTING NO HIGHRISE OFFICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71061	18041-10000-07858	1000 S SANTA FE AVE	90021	14	123A217   189	5166005001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.03143	-118.22981	Install New Fire alarm system on New 8 story hotel (note** plan check engineer to verify w/ number of story under 17010-10000-03362 and 16041-20000-44615), scope consists of (10) FA panels, and (707) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71062	18041-20000-40644	5990 N SEPULVEDA BLVD 1st-2nd Floor	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.17911	-118.46588	New outdoor lighting and renovation of interior 1st and 2nd floor common areas.  Title 24 plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71063	17041-20000-37893	9537 N ENCINO AVE	91325	12	201B129   396	2755009047	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.24444	-118.5157	permit fee $0.00 by statye senate bill no. 1222pv1install roof mounted pv system sized 11.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71064	16041-20000-00440	12667 N SAN FERNANDO ROAD	91342	7	219B145   169	2604028005	C2-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM			Re-Activate Permit	05/21/2018 12:00:00 AM	ADDRESS	34.29944	-118.45997	Plan check for New 3 story commercial building, office space and 1st floor restaurant; core and shell. Service size: 1,200A. Total area:18,478 sq ft.Note: Building application has been generated under 15010-20000-01828	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71065	14041-10000-23353	135 S BARRINGTON AVE	90049	11	135B145   620	4401007018	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM			PC Approved	08/26/2014 12:00:00 AM	ADDRESS	34.06441	-118.46926	tenant inide a dinerplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71066	15041-20000-41309	23213 W LIAHONA PL	91364	3	168B093   254	2074033021	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.15453	-118.63144	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac. (25)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71067	16041-10000-22392	3273 W CASITAS AVE 100-102	90039	13	153B209   393	5436002023	MR1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	04/21/2017 12:00:00 AM	ADDRESS	34.11638	-118.25202	First time T.I. to (e) core and shell office building (Building B) Approx 1,365 sf.ft. Main Electrical equipment is under separate permit. This PC for T-24 only.B# 16016-10000-14613	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71068	16041-20000-36094	420 S GRAND AVE 14th Floor	90071	14	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.05094	-118.25298	Plan check for power and energy. Project site is the 14th floor of an existing commercial high-rise building. Project scope is a tenant improvement and the installation of (2) 900 kVA UPSs and associated distribution equipment. Note: Building application has been generated under 16016-10000-19699	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71069	16041-20000-27068	12675 W SEACOAST PL	90094	11	102B161  1279	4211037***	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.97626	-118.41382	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.1.5kW ungrounded system. (6) 250W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71070	15041-10000-35022	2200 S ALAMEDA ST	90058	14	117A215    31	5167006023	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	10/20/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.01616	-118.23945	Energy plan check check for removing HID light fixtures and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71071	15041-10001-40387	302 E 116TH PL	90061	15	084B205  1530	6083008062	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2016 12:00:00 AM			PC Approved	04/07/2016 12:00:00 AM	ADDRESS	33.92814	-118.26936	PV1, INSTALL 3.315 KW DC ROOF-MOUNTED FOR A SINGLE FAMILY HOUSE. (13) MODULES:  YINGLI YL255P-29B(1) INVERTER: SOLAREDGE: SOLAREDGE SE 3800A-US Note: Inspection fees was paid for under permit number 15041-70000-40387	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71072	19041-20000-44230	1413 S WESTWOOD BLVD	90024	5	132B153   897	4324010010	C4-1VL-POD	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.05485	-118.44162	ENERGY ONLY T24 PLAN CHECK. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 3851 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71073	10041-10000-04980	800 E 12TH ST 1-119	90021	9	123A211   117	5132012062	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	04/05/2010 12:00:00 AM	ADDRESS	34.0321	-118.25055	title 24 for unit 114.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71074	14041-10000-13705	6255 W SUNSET BLVD	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			05/22/2014 12:00:00 AM	05/22/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Title 24 for existing commercial highriseCorridor and restroom remodel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71075	12041-10005-28750	"3740 W EVANS ST BLDG ""D"""	90027	4	150B201   845	5433023040	R2-1XL	Central	Hollywood	Greater Griffith Park	YES	1952.01	Electrical	Electrical	Apartment			04/09/2014 12:00:00 AM			PC Approved	05/21/2014 12:00:00 AM	ADDRESS	34.10626	-118.27387	"Value engineering, change coductor sizez and rerout.  some feeders reduced in size and some increased.  M.Z.  4-9-14  (((((((((((((((A LTERATION OF FOUR BUILDINGS ""A"", ""B"", ""C"" & ""D"". SERVICE UPGRADE,  ADDITION OF NEW METERS AND DISTRIBUTION PANELS, ADDITIONAL CIRCUITS TO UNITS, NEW AC UNITS,  NEW UTILITY TRANSFORMER ON SITE. THIS PERMIT IS FOR BUILDING ""D"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71076	19041-20000-27132	15301 W VENTURA BLVD 3rd Floor	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	01/21/2020 12:00:00 AM	ADDRESS	34.15411	-118.46654	Remodel to (E) commercial corridor and restrooms.  Plan check for energy - 6693 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71077	15041-20000-22263	8517 N KESTER AVE	91402	6	192B149   144	2653014012	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.07	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.22526	-118.4576	PV1. Install roof mounted PV system sized 4.7 kW. Interconnected with main service panel. (22) SW 280 Modules(22) Enphase M215 Micro-inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71078	13041-20000-35297	3703 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.01924	-118.35578	Change to lighting in an existing single-story office building.  <NOT A MEDICAL OFFICE, NO PATIENT CARE>  Load is less than 150 amps per the contractor.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71079	14041-10000-06741	6565 W HOMEWOOD AVE	90028	4	147A187   330	5547027019	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Expired	07/22/2016 12:00:00 AM	ADDRESS	34.09533	-118.33264	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOALR ARRAY ON A  1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(12) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71080	16041-20000-07980	10033 W MCBROOM ST	91040	7	207B181    48	2543008017	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2016 12:00:00 AM	03/07/2016 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.26437	-118.3494	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. (26) 285 pv modules. Each module has a 300W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71081	17041-20000-18544	23155 W OXNARD ST	91367	3	177B093   699	2039008025	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM	06/02/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.1793	-118.6316	PV1. ROOFMOUNTED SOLAR SYSTEM. ACM STANDARD PLAN. SYSTEM SIZE: 6.4 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71082	19041-10000-52665	3007 N LAKE GLEN DR	90210	4	159B161   426	4386003017	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2019 12:00:00 AM	12/20/2019 12:00:00 AM		Permit Finaled	05/14/2020 12:00:00 AM	ADDRESS	34.1282	-118.40932	INTALLATION OF ESS TO AN EXISTING PV1 SYSTEM. ESS TESLA POWER WALL. CONNECTED TO AN EXISTING 200 AMP SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71083	16041-10000-14779	4905 W HOLLYWOOD BLVD	90027	4	147B197   191	5589038036	C2-1D	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.10198	-118.29645	FULL PC FOR A NEW  ORCHARD SUPPLY HARDWARE STORE, AND PARKING LOT. NEW 1600 AMP UNDERGROUND SERVICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. FOR INDOOR AND OUTDOOR IS   83179.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71084	14041-10001-26004	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	(((11-4-2015: CHANGES MADE TO APPROVED SET. CHANGES TO SERVICE AND LOADS. ALL CHANGES HAVE BEEN CLOUDED AND DELTA 15)))PC FOR POWER AND ENERGY. WORK WITHIN EXISTING PARKING LEVELS, REPLACE DWP SERVICE, ADD DISTRIBUTION FOR NEW TENANTS, ADD AND REPLACE PKG LIGHTING. TOTAL AREA 1423101 SQ FT. PHASE 3.PLAN CHECKER RE-VERIFY THE FEES<<<EVERYTHNG ON PAGES 3.E.04.07 AND AFTER  ARE NEW JOBS AND BEFORE  THIS PAGE IS  EXISTIN AND DOING SOME ADDING AND REPLACING.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71085	13041-10001-16473	750 S LAMAR ST gate bldg	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	CHANGES TO APPROVED PLANS FOR THE UNION PACIFIC LATC INTERMODAL YARD PROJECT. MOST OF THE CHANGES HAS TO DO WITH THE ELECTRICAL DISTRIBUTION SYSTEM WHICH IS IN THE GATE BLDG PLANS.  CHANGES TO PLANS OF OTHER BLDGS/CANOPY/STRUCTURES CAN BE PLAN CHECKED UNDER THIS APPLICATION. NOTE, ALL CHANGES UNDER CLOUDED AREA ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71086	10041-20000-23977	4751 W WILSHIRE BLVD 1st Floor-Lobby	90010	4	135B185   565	5505001021	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM			PC Info Complete	12/02/2010 12:00:00 AM	ADDRESS	34.06219	-118.3337	T.I. of the existing lobby area in the first floor.  Install general/emergency light.  Plan check for energy only.Note: Permit is under 10041-10000-22591	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71087	15041-10000-28769	16141 W HART ST	91406	6	183B141   370	2224010158	[Q]MR1-1VL	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.19768	-118.48497	T-24. PC FOR ENERGY ONLY FOR AN EXISTING COMMERCIAL (STORAGE) BUILDING. SCOPE INCLUDES NEW LED LIGHTING IN INDUSTRIAL STORAGE AREA. TOTAL AREA = 4000 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71088	17041-10000-29581	22404 W ITASCA ST	91311	12	201B101   532	2727001012	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.24427	-118.61503	PC for 18.63kW PV roof mounted system for single family home with 54 AC modules and one 125 A load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71089	11041-10004-10748	1900 S SEPULVEDA BLVD	90025	5	126B153   181	4323022031	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM			PC Approved	05/17/2012 12:00:00 AM	ADDRESS	34.04447	-118.4413	REVISIONS TO PERMITTED SET OF PLANS:ATTACHED TO THE PLANS ARE THE LISTS OF CHANGES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71090	19041-20000-06903	624 S GRAND AVE 2600	90017	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.04802	-118.25572	T24 PLAN CHECK LIGHTING AND OUTLETS ONLY FOR EXISTING COMMERCIAL BUILDING, TOTAL SQUARE FOOTAGE = 497 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71091	16041-30000-04980	9040 W PICO BLVD	90035	5	132B169   879	4305007029	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2170.01	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.05505	-118.38885	Installation of new fire alarm system in existing 1 story building being converted to religious center.  Total system size = 28 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71092	12041-10000-19919	10118 N SAN FERNANDO ROAD	91331	7	204B161   473	2537010032	[Q]CM-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			08/23/2012 12:00:00 AM	10/02/2012 12:00:00 AM		Permit Finaled	03/01/2013 12:00:00 AM	ADDRESS	34.25423	-118.40867	CHANGE OF USE FROM RETAIL TO RESTAURANT.  Load is 180Amps and occupancy load is 49, per applicant.  Plan check only for Energy, with Emergency lighting.  Permit Fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71093	18041-10000-22405	197 E JEFFERSON BLVD	90011	9	118-5A205 269	5120005010	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	01/28/2020 12:00:00 AM		Issued	01/28/2020 12:00:00 AM	ADDRESS	34.01748	-118.2697	SERVICE UPGRADE TO 2,000AMPS, NEW PANELS, TRANSFORMERS & CIRCUITS. PLAN CHECK FOR POWER. Building Permit Number: 18016-10000-11413Note: The acutal location of the HomeRuns for the 277V Lights is not known at this time, A typical HR is shown on the plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71094	18041-10000-16166	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			05/02/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.12626	-118.21412	PC ROF TITLE 24 ENERGY ONLY. FOR CLASSROOM TI IN OCCIDENTAL COLLEGE (FOWLER HALL ROOM 320).  SCOPE INCLUDE NEW LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA 939 SQ.FT  B# 18016-10000-12831	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71095	18041-10000-45235	2003 N EDGEMONT ST	90027	4	150B197   493	5589015006	R1-1	Central	Hollywood	Los Feliz		1892.02	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.10792	-118.29643	NOTE: PERMIT FEES ARE $0 DUE TO AB 1414NEW ROOFTOP SOLAR SYSTEM CONSIST OF 56 MODULES (LG 360Q) , 56 OPTIMIZER (SE P370) AND TWO CENTRAL INVERTER (SE7600H-US & SE7600A-US).  SYSTEM SIZE IS 20.16KWdc and 15.2KWac.SCOPE INCLUDES NEW 125A LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71096	11041-10000-17392	12318 W VENTURA BLVD	91604	2	162B165   251	2369002026	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	ADDRESS	34.14284	-118.40154	INTERIOR NON STRUCTURAL TENANT IMPROVEMENT TO (E) 100' X 100'  TYPE V  BUILDING FURNITURE STORE   PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71097	14041-20001-13008	5166 N TOWNSEND AVE	90041	14	163-5A227 268	5669013025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.14151	-118.20097	PV1MODIFICATION TO PROPOSED ROOF LAYOUT.  SUPPLEMENTAL TO APPROVED SET 14041-20000-13008	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71098	14041-20000-11002	9301 N TAMPA AVE #183	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM			PC Info Complete	05/30/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	ENERGY CHECK FOR EXISTING SHOPPING CENTER OF RETAIL SPACE 1664 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71099	18041-20000-45349	1453 W TEMPLE ST	90026	1	136-5A209 218	5160005900	CW	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.06776	-118.25826	Remodel of (E) 2-story office and laboratory building.  New power and  lighting newly connected load over 400A connected to existing 1200A Service.   Building permit under 18016-10000-11155.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71100	18041-10000-12201	170 S GLESS ST	90033	14	127-5A219  27	5172003042	RD3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	34.04542	-118.22293	INSTALLATION OF A FIRE ALARM SYSTEM. 1 FACP ,  20 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71101	17041-10001-20525	4089 S LINCOLN BLVD	90292	11	108B149  1645	4229005097	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM			PC Approved	10/30/2017 12:00:00 AM	ADDRESS	33.98834	-118.44602	Thsi is plan check only, permit is covered under  master permit# 17041-10000-20525. Revision to approved plan noted under Delta 1: add lighting fixture, and revise T24 information and lighting floor plan accordingly.        <<Title 24 plan check.  T.I. to existing restaurant and bar with no change of use.  Existing 400 amp service to remain existing with 2 new subpanels.  New lighting, receptacles, and HVAC.  Lighting area = 3,040 sq. ft. (indoor) + 17,620 sq. ft. (outdoor).   Building permit #17016-10000-11630 >>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71102	11041-10000-27499	5941 W GREGORY AVE 1-4	90038	13	141B189    35	5534030021	R3-1XL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			12/28/2011 12:00:00 AM	12/28/2011 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	34.08631	-118.32592	INSTALL A NEW FIRE ALARM SYSTEM IN A 4 UNIT APARTMENT BUILDING. 1 PANEL & 24 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71103	15041-10000-07084	220 E ROSE AVE	90291	11	111B141   714	4286004002	M1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	33.99624	-118.47721	REMODEL EXISTING RESTAURANT; CHANGE OUT PANELS AND REPLACING KITCHEN EQUIPMENT; NEW LIGHTING SYSTEM; FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71104	16041-20000-12876	1451 E 4TH ST	90033	14	127-5A219 339	5172020009	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	08/18/2016 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.04249	-118.22532	New 1600A 120/208V service for (E) commercial building.  Plan check for power.  NO CIRCUITS, PANELS ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71105	16041-20001-26716	1155 N ANGELO DR	90210	5	144B157   353	4358009008	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			06/03/2019 12:00:00 AM			PC Approved	06/03/2019 12:00:00 AM	ADDRESS	34.08979	-118.43217	06-03-2019 Changes to permitted set of plans, changes include remove 60KW generator and replace with 22KW Generator for sump pumps and add access motor court. Plan check only. Electrical permit covered under Building Combination Permit 16014-30000-00284	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71106	18041-20001-39530	1923 N GRAMERCY PL	90068	4	150A193   111	5587019007	R1-1D-HPOZ	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2019 12:00:00 AM			PC Approved	02/05/2019 12:00:00 AM	ADDRESS	34.10606	-118.31272	Change of module from Solarcity Standard SC325 to Solarcity Standard SC330.  PV DC kW rating adjusted to 9.57 kW. $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.(((Plan check for PV roof mounted system with energy storage system, PV Syste size: 9.425 KW with 29 PV Modules and 1 inverter(7.6kW) and 1 Tesla Battery 2.0 13.5kWh.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71107	16041-10000-43087	10348 N SEPULVEDA BLVD	91345	7	204B145   168	2649019009	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.25886	-118.46706	Plan check for Title 24 only in exising space conference room, subdivide exising conference room into 2 rooms T.I. Total area: 1,594 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71108	15041-10000-10892	3303 N NORTH BROADWAY	90031	1	138A225    15	5208012006	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	12/23/2019 12:00:00 AM	ADDRESS	34.07394	-118.20626	Plan check for power and energy for New 3 story commercial building 480/277V 1600 A Service shell only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71109	15041-10000-21004	7310 N DEERING AVE	91303	3	186B105   827	2112025034	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.21	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	07/02/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.20322	-118.59653	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY.  TOTAL SQUARE FOOTAGE 4192.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71110	19041-20000-30038	13756 W BAYLISS ROAD	90049	11	141B133   338	4492020047	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.0787	-118.5071	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 7.25 KW DC/7.245 KW AC. SCOPE OF WORK CONSISTS OF (21) PV MODULES WITH INTEGRATED MICRO INVERTERS AND 2 SUB PANELS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71111	14041-20000-17257	6621 N FALLBROOK AVE 2nd FLOOR	91307	12	180B097   429	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM			Reviewed by Supervisor	07/08/2014 12:00:00 AM	ADDRESS	34.19037	-118.62371	pc for fire alarm sytem for the second floor.second floor TI. pc for power and energy. load greater than 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71112	19041-10000-22254	555 S FLOWER ST 42nd FLR	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Issued	06/11/2019 12:00:00 AM	ADDRESS	34.05048	-118.25755	T-24 PLAN CHECK FOR A RESTROOM REMODEL ON THE 42ND FLOOR. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFCETED AREA IS 870 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71113	18041-10000-48428	1919 W SAN FERNANDO RD	90065	1	148-5A215  96	5442004035	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Issued	12/21/2018 12:00:00 AM	PIN	34.10090188	-118.2356124	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71114	15041-10000-32794	11726 W SAN VICENTE BLVD 6th floor	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	ADDRESS	34.05328	-118.46625	T-24, TI to an existing 26-story commercial building. Existing service and equipment. Installing new lighting on the 6th floor. PC for energy only. SQ ft = 577	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71115	18041-10000-33116	5028 W VENICE BLVD	90019	10	126B181    93	5067003044	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.04525	-118.34773	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71116	18041-10000-19058	606 S IMPERIAL ST	90021	14	126A217   174	5164014012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.03779	-118.23143	Energy plan check for a retail T.I. Scope includes new lighting and equipment; total area is  5255 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71117	13041-10000-17772	12335 W VENICE BLVD	90066	11	111B153    61	4248032003	[Q]C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.00402	-118.43332	permit to be pulled at EPC counter only. PC for energy only.TI TO EXISTING CHASE BANK. addition of 3 lights (2 in the lobby and 1 in the office).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71118	16041-20000-36376	825 S WALL ST	90014	14	126A211   208	5145011015	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.03968	-118.25114	remove existing hid fixtures and replace with new led fixtures outdoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71119	17041-10000-01968	6300 N OWENSMOUTH AVE	91367	3	177B105     5	2146005901	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.18465	-118.60131	T24 ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, TOTAL AREA 143300 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71120	13041-10001-06741	4554 N SANCOLA AVE	91602	4	168B177   924	2420036003	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	34.15368	-118.35366	(((CHANGES TO APPROVED SET. MOVING EQMT (DWP meter , AC disconnect)  FROM HOUSE TO detached GARAGE.))) SINGLE FAMILY DWELLING. PHOTOVOLTAIC SYSTEM TOTAL SYSTEM SIZE 5.6 KW. TOTAL OF 26 UNITS. USING ENPHASE MINCROINVTERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71121	12041-10000-13639	1063 S LA BREA AVE	90019	10	132B181   941	5084012024	C2-1	Central	Wilshire	P.I.C.O.		2162.00	Electrical	Electrical	Commercial			06/12/2012 12:00:00 AM			PC Approved	06/12/2012 12:00:00 AM	ADDRESS	34.05558	-118.34465	T.I. to an existing Retail  furniture store.  Load is less than 200A per applicant and occupancy load is less than 99 per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71122	13041-10000-16396	1630 N NORTH MAIN ST	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	ADDRESS	34.06682	-118.22728	Title 24 and energy for a one story office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71123	14041-10000-12209	2700 S FIGUEROA ST #103	90007	9	121-5A203  98	5123018033	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	07/14/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.02708	-118.27647	permit to be pulled at EPC counter only.plan check for energy only.  5 stories. emergency lights installed. lightsBLDG#14016-10-08784: INTERIOR TENANT IMPROVEMENT FOR RESTAURANT; NEW NON BEARING PARTITIONS, COUNTER, SEATING, FIXTURES, AND FREEZER/COOLERS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71124	11041-20000-13135	5445 W HOLLYWOOD BLVD suite D	90027	13	148-5A193 342	5544007***	C4-1D, C4-1VL, R3-1	Central	Hollywood	Greater Griffith Park		1904.02	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM			PC Approved	07/11/2011 12:00:00 AM	ADDRESS	34.10195	-118.3085	energy plan check chase bank	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71125	17041-30000-28206	1854 S SAWTELLE BLVD #101	90025	11	126B153   436	4261020019	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM			PC Approved	01/23/2018 12:00:00 AM	ADDRESS	34.04272	-118.44498	Plan check for Title 24 only in existing space T.I. cafe. Total area: 660 sq ft. Plan check only. Permit was pulled under 17041-10000-45809	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71126	14041-20000-10265	7521 N LINDLEY AVE	91335	3	186B125   359	2119006014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.20728	-118.52748	PV1 roof-mounted system with (2) SE3800A-US-ZB-U transformerless inverters, (33) Canadian solar modules, optimizer.  System size 8.25KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71127	18041-20001-47967	16556 W BIRCHER ST	91344	12	213B137   401	2610027031	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.2811	-118.49302	Revision to approved plans.  Relocation of inverter to other side of gate by service equipment.  Omission of (1) AC disconnect.  $0 plan check fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414. (((PV1.  Install 10.5 kW DC roof mounted grid tied PV system.  (30) modules with 10 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71128	17041-20000-14047	1044 S TIVERTON AVE	90024	5	132B153   151	4360002006	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.06077	-118.443	Plan check for power only.  Service upgrade to 600A for (E) hotel.  (4) 75 kVA transformers and (5) new panels.Note: Title 24 has been plan checked and approved under application 17041-20000-32135. Title 24 permit fees have been included on this application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71129	15041-10000-04003	1149 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	34.03001	-118.22065	Plan check for T-24. Remove HID light fixtures and replace with new LED fixtures. Total area: 7608 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71130	16041-20001-41870	16551 W SAN FERNANDO MISSION BLVD	91344	12	210B137   414	2681016011	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.27212	-118.49285	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of a solar pv system, roof-mounted on a SFD. Interconnect with a 200A MSP.6kW ungrounded system. (20) 320W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71131	10041-20000-12720	12039 W BRANFORD ST	91331	7	204B165   189	2537017017	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM			PC Approved	07/02/2010 12:00:00 AM	PIN	34.25485468	-118.39602222	Changes to ORGINAL PLAN 05041-20000-08021.  SOME LIGHTING AND LOAD REVISED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71132	17041-10000-20926	11601 W WILSHIRE BLVD 2110	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR TI WORK IN OFFICE ( HIGH RISE) FOR TITLE-24 ENERGY ONLY.INSTALLING NEW LIGHT  AND ONE LIGHTING CIRCUIT(277V). TOTAL  AFFECTED AREA 2021 SQ.FT. BL# 17016-10000-11894	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71133	15041-20000-28867	1840 S CENTURY PARK EAST #430	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.06188	-118.41473	Plan check for Title 24 only in existing space high-rise building. Total area: 4,602 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71134	18041-20000-46183	17655 W DEVONSHIRE ST pv3	91325	12	204B129    58	2733013009	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/05/2018 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	10/28/2019 12:00:00 AM	ADDRESS	34.25781	-118.51928	pv3install roof mounted pv system sized 72KW AC interconnected with msp.  (277) sunpower spr-p17 modules(140) solaredge P800 optimizers(1) 43.2KW inverter(2) 14.4KW invertersPermit Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71135	16041-20000-23565	4321 W FINLEY AVE	90027	4	150B201   560	5591009032	R2-1XL	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2016 12:00:00 AM	07/06/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.10781	-118.28367	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 1.71 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71136	14041-10000-21207	695 S VERMONT AVE 16 Floor	90005	10	132B197   178	5094008026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.06016	-118.29183	PLANCHECK FOR T24 ENERGY. COMMERCIAL OFFICE TENANT IMPROVEMENT. 13975 S.F. , EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71137	19041-10001-09012	10342 N LOUISE AVE	91344	12	204B133    94	2695015009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM			PC Approved	04/09/2019 12:00:00 AM	ADDRESS	34.25893	-118.51089	"DELTA ""1"" CHANGES TO APPROVED PLANS FOR RELOCATING THE INVERTER.Plan Check ONLY. Permit#: 19041-10000-09012<<<Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWdc/4.301 kWac-CEC and consists of (1) 7.6 kWac rated inverter and (16) modules. Standard plan is not being used.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71138	17041-10000-33038	5426 N SATSUMA AVE	91601	2	174B173  1347	2416015003	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.16934	-118.36741	Power plan check only for service upgrade to 600A 120/240 V, 3ph, 4W. Loads are existing.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71139	17041-10000-01953	2001 S BARRINGTON AVE #215	90025	11	123B149   118	4262031014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			01/20/2017 12:00:00 AM			PC Approved	01/20/2017 12:00:00 AM	ADDRESS	34.03683	-118.45028	PC for energy only. TI to exiting office building (suite 215). Adding new lighting and power. Total area: 1385.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71140	17041-30000-45890	2100 W 3RD ST Suite 220	90057	1	135A205   243	5154030034	C2-1	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Permit Finaled	04/11/2018 12:00:00 AM	ADDRESS	34.06281	-118.2731	Plan check for power and energy. Project site is a portion of the 2nd floor of an existing commercial building. Project scope is a change of use from research lab to an OSHPD-3 dental clinic/tenant improvement. Total lighting area = 6,071 sq. ft.Note: Building application has been generated under 17016-10000-36883.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71141	16041-20000-23740	20953 W OSBORNE ST	91304	3	195B109    47	2779001030	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	34.23315	-118.59033	Plan check for Power and Energy in existing building T.I. 800A Service for Youth Center. Total area: 18,668 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71142	13041-10000-12948	941 S BLOOM WALK	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Info Complete	05/17/2013 12:00:00 AM	PIN	34.02030756	-118.28890608	13041-10000-12948TI title 24 only in IT room USC univ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71143	19041-20000-50868	736 E SUPERBA AVE	90291	11	108B145   850	4241021004	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	05/03/2020 12:00:00 AM	ADDRESS	33.99271	-118.46006	PLAN CHECK FOR ALTERATION TO EXISTING PV SYSTEM AND NEW ESS. PV SYSTEM SIZE IS 4 KW DC/3.468 KW AC. ESS SIZE IS 9.3 KWH. SCOPE OF WORK INCLUDES (1) 5 KVA TRANSFORMER, (1) 5 KW BATTERY, A 3.8 KW INVERTER, AND A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71144	14041-10003-17121	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	03/19/2024 12:00:00 AM	ADDRESS	34.03941	-118.25893	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 25 BULLETIN 42. CHANGES INCLUDE RELOCATING PANELBOARDS ON THE SINGLE LINE DIAGRAM, RELOCATING LOADS ON PANEL SCHEDULES, RELOCATING CIRCUITRY ON THE FLOOR PLANS, REVISING SERVICE LOAD CALCULATIONS, AND REVISING TITLE 24 CALCULATIONS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71145	16041-20000-04897	8600 N GLENOAKS BLVD 1-60	91352	2	192B177    43	2404009013	(T)(Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1021.03	Electrical	Electrical	Apartment			02/11/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.22667	-118.36307	Plan check for a power and energy. Project site is a new 3-story, 60-unit apartment building: 3 floors of residention over 1 level of basement parking garage. Servize size is 1600 amps. Total indoor lighting area = 40,390 sq. ft. and total outdoor lighting area = 5,029 sq. ft.Note: Building application has been generated under 15010-20000-04561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71146	13041-10000-30310	1875 S CENTURY PARK EAST basement-pkg roof	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	11/17/2014 12:00:00 AM	ADDRESS	34.06115	-118.41457	PC for power and energy. INSTALLING NEW CENTRAL PLANT IN BASEMENT shared by two twin highrises. cooling towers to go on roof of adjacent parking structure. METHANE zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71147	12041-20000-09404	527 S PARK VIEW ST	90057	1	135A203   403	5154038900	R4-1	Central	Westlake			2088.02	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM			Reviewed by Supervisor	05/01/2012 12:00:00 AM	ADDRESS	34.06199	-118.27742	T.I. to existing warehouse.  Install  panels, transformer, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71148	17041-10000-16480	1222 S ALVIRA ST	90035	5	132B173  1250	5087015005	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.05402	-118.37245	PC FOR ROOF MOUNTED PV SYSTEM.SYSTEM SIZE 3.0 KWACINCLUDES 12 MOUDLES AND SINGLE INVERTER SOLAR EDGE 3000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71149	15041-10001-24061	1500 W PACIFIC COAST HWY Bldg F1	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION of 6 devices for future ADA Requirement.(((NEW FA SYSTEM FOR A New 2-story, 2 unit apartment with garage, . 11 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71150	15041-20000-22789	600 WORLD WAY Space 634	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	12/31/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	Title 24 plan check only.  Total area = 1,310 sq. ft.  T.I. to existing commercial space.  New 400 A panel to provide power.  Upgrading 845 sq. ft. walk in cooler as well.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71151	15041-10001-43604	1746 S LA CIENEGA BLVD	90035	10	129B173  1522	5066006032	C2-1	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	08/08/2016 12:00:00 AM	ADDRESS	34.0458	-118.37629	04/08/2016CHANGES TO AN APPROVED SET OF PLANS, NOTE CHANGES ON DELTA 2. CHANGES INCLUDE THE ADDITION OF OUTDOOR LIGHTING AND AN OUTDOOR CIRCUIT. (((PC FOR ENERGY. TI FOR A NEW STARBUCKS CAFEE (PREVIOUSLY BURGER KING) . TOTAL AREA 2910 SQ FT.B# 15016-10000-28309)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71152	18041-20000-14924	11835 W OLYMPIC BLVD SUITE 110E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/24/2018 12:00:00 AM	08/02/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.03301	-118.45119	Plan check for energy only in existing high-rise building bank T.I. new lighting and receptacle. Total area: 3223 sq ft. B#18016-20000-12513	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71153	15041-20001-03075	12491 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	03/01/2015 12:00:00 AM	ADDRESS	33.97895	-118.41081	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71154	17041-10000-30101	2049 N SICHEL ST	90031	1	136-5A223 114	5210010043	RD2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Issued	08/23/2017 12:00:00 AM	ADDRESS	34.06904	-118.2132	PC FOR PV SYSTEM USING 15 MODULES AND CENTRAL INVERTER RATED 3.8KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71155	18041-10000-05755	1030 N SWARTHMORE AVE #2-112	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	Full Plan check per customer request. Scope include new lighting and equipment.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71156	17041-20002-35098	9526 N HUNT CLUB LANE	91311	12	201B097   164	2724011037	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	Yes	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	34.24356	-118.62166	10/27/2017 Changes to an approved set of plans. Changes have been made to the PV module being used. All other equipment has remained the same.*****Previous Work Description*****PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.4 KW.$17.93 permit fee due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71157	15041-20000-22019	3650 S MCCLINTOCK AVE 100B/100C	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM			PC Approved	07/10/2015 12:00:00 AM	ADDRESS	34.02081	-118.28964	Plan check for USC class room T.I. Title 24 only. Total indoor area: 1,723sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71158	19041-20000-52440	9341 N SHIRLEY AVE	91324	12	198B117   106	2761036037	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	04/30/2021 12:00:00 AM		Permit Finaled	09/14/2021 12:00:00 AM	ADDRESS	34.24075	-118.55809	$0 PERMIT FEE DUE TO AB1414PV3.  Install 276.8 KW DC/251.11 KW AC CEC roof mounted PV system.  (692) modules with (7) 33.3 KW inverter, (2) 200A panel, (1) 400A panel, and a 250KVA transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71159	15041-20000-05703	1705 W 85TH ST	90047	8	097-5A193 181	6034025012	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2015 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	04/23/2015 12:00:00 AM	ADDRESS	33.96102	-118.30711	Plan check for a PV1 roof-mounted PV system. System size is 4 kWAC and consists of (19) modules, (19) micro-inverters, and (1) 100-amp rated load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71160	18041-10000-30760	4911 N LOLETA AVE	90041	14	160-5A227  62	5689023021	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.13541	-118.19822	"""32.75$ permit fee due to senate bill 1222, AB 1414 ""NEW ROOF MOUNTED 11.75 (AC) KW PV SYSTEM ON A SINGLE FAMILY HOME WITH 37 PV MODULES."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71161	16041-20001-40729	17526 W INDEX ST	91344	12	210B129    73	2711007029	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.27562	-118.51632	VOID....................pv1install ground mount system 3.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71162	19041-30000-11222	430 S BURNSIDE AVE Tower 38	90036	4	135B181   198	5509005006	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Apartment			04/11/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/20/2022 12:00:00 AM	ADDRESS	34.06654	-118.35077	Plan check for power only. Project site is an existing 13-story, 153-unit apartment building. Project scope is a service upgrade to 4,000 Amps. Work includes new service and distribution equipment. Existing tenant panels will be re-fed. This scope of work does not include any new loads within units. Indicated house loads will be re-fed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71163	17041-10000-23776	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	08/30/2018 12:00:00 AM	ADDRESS	33.98489	-118.42552	FULL PC FOR POWER AND ENERGY. REMODELING OF (E) 2,200SF DATA EQUIPMENT AREA TO ADD NEW ELECTRICAL CABINETS. SCOPE INCLUDES TWO NEW 1600A DISTRIBUTION BOARDS, NEW PANELS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 227 SQ. FT. B#17016-10000-19294	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71164	14041-10000-02438	3201 W OLYMPIC BLVD	90006	10	129B193   277	5080015036	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM			PC Approved	01/28/2014 12:00:00 AM	ADDRESS	34.05276	-118.30656	TENANT IMPROVEMENT IN EXISTING DENTAL OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71165	11041-10000-20970	5700 N CANOGA AVE #400	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/30/2011 12:00:00 AM			Not Ready to Issue	11/23/2011 12:00:00 AM	ADDRESS	34.17365	-118.59715	TI ON 4TH FLOOR; TENANT EXPANSION TO INCLUDE (N) PARTITIONS, Title 24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71166	12041-10000-01637	20022 W VENTURA BLVD	91364	3	174B113   466	2166001020	C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	02/08/2012 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.17141	-118.56915	New Fire Alarm for a restaurant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71167	11041-10000-02730	1039 W FLORENCE AVE	90044	8	102B197  1118	6014036019	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM	03/25/2011 12:00:00 AM		Permit Finaled	05/20/2011 12:00:00 AM	ADDRESS	33.97478	-118.29326	"T.I. FOR AN EXISTING ONE STORY PAINT SALES & PAINT STORAGE BUILDING TO MEDICAL CLINIC OFFICE; NEW TYPE INTERIOR WOOD WALLS UP TO 9'0"" HT CEILING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71168	15041-10000-16968	5700 W HOLLYWOOD BLVD	90028	13	148-5A191 149	5586035036	[T][Q]C2-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.10155	-118.31391	FULL PLAN CHECK FOR A NEW HYDROGEN FUELING STATION LOCATED IN AN EXISTING GAS STATION (HAZARDOUS LOCATION). TOTAL SQ FT FOR OUTDOOR LIGHTING: 7200.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71169	19041-20000-08256	6000 N DE SOTO AVE	91367	3	177B109    16	2149004023	(Q)R4-2D	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Issued	04/24/2019 12:00:00 AM	ADDRESS	34.17936	-118.58884	PV2.  Install 136.88 kW DC / 125.07 kW AC roof mounted grid tied PV system.  (375) modules with (4) 33.3 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222 and State Assembly Bill AB 1414.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71170	16041-20000-21799	10646 W STALLION RANCH ROAD	91040	7	204B177   255	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.25903	-118.36199	PERMIT FEE $0.00 STATE SENATE BILL NO.1222PV1.  Install roof mounted PV system.  (86) modules with microinverters.  (1) solar monitoring circuit.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71171	13041-10000-20475	12220 W OLYMPIC BLVD	90064	11	123B149   622	4259025018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			08/01/2013 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.03186	-118.45556	REPLACING EXISTING 300KVA UPS WITH 225 KVA, PLUS 1 800 AMP PANEL, 225KVA TRANSFORMER. PLANCHECKER ASK FOR DEMAND ON SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71172	10041-10000-01486	5165 W FOUNTAIN AVE	90027	13	147A195   255	5544038018	R3-1, RD1.5-1XL	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM			PC Info Complete	02/10/2011 12:00:00 AM	PIN	34.09560111	-118.30193166	Existing Church of Scientology - service upgrade - 1600 A 120/208V.  Permit is for new service, new panelboards, new lighting, equipment, etc.  P/C is for Power and Energy. T-24 FEES WERE NOT CALCULATED AT TIME OF SUBMITTAL; FEES WILL NEED TO BE CALCULATED PRIOR TO APPROVAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71173	14041-20000-15596	10403 W VALLEY SPRING LANE	91602	4	165B177   796	2424015018	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.14687	-118.35734	(($0 permit fee due to senate bill 1222 from 2012))PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 14.8KW AC USING 4 CENTRAL TRANSFORMERLESS INVERTERS. NONSTAND PLAN. NEW 400A PANEL. EXISTING 200A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71174	11041-10000-02704	865 S FIGUEROA ST Suite 3000	90017	9	129A207   237	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	02/10/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.04653	-118.26275	Remodel of the BIM and Conference room in suite 3000. T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71175	16041-10000-29175	3024 N ROSSLYN ST	90065	13	156B209   237	5458004020	M1-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	09/26/2016 12:00:00 AM		Permit Finaled	09/13/2018 12:00:00 AM	ADDRESS	34.12137	-118.25106	PC FOR POWER ONLY. SCOPE INCLUDES INSTALLING A NEW 1600A 277/480V, 3 PHASE, 4 WIRE MAIN SWITCHBOARD DUE TO FIRE DAMAGE, 45KVA XFRMR, PANEL 'MA' & 'PA' WITH ITS CIRCUITS. ALL OTHER WILL BE FOR FUTURE (SEPARATE) PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71176	13041-10000-02391	11976 W CULVER BLVD 1-124	90230	11	108B161   154	4218007025	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Apartment			01/30/2013 12:00:00 AM			PC Approved	02/14/2013 12:00:00 AM	ADDRESS	33.99512	-118.4173	REQUEST BY INSPECTOR MIKE DAWSON TO BRING PLANS PER CHANGES IN THE FIELDNew 124-units affordable housing 4-storie over parking garage on grade. EPC is for power & Energy. (T24 fee is not included)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71177	17041-10002-34940	4308 W SUNSET BLVD	90029	13	145-5A201  87	5429006011	C2-1D	Central	Hollywood	Silver Lake		1913.02	Electrical	Electrical	Commercial			12/12/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM	ADDRESS	34.09467	-118.28331	PC FOR CHANGES TO APPROVED SET *******************************FOR TITLE 24 ENERGY ONLY!!******************************* SCOPE INCLUDES CHANGES TO LIGHTING FIXTURE COUNT DUE TO ADDITION OF CELING HEATERS. SOME ADDITINONAL CIRCUITS AND EQUIPMENT.  ALL CHANGES MARKED UNDER DELTA 3 AND 4. SUPP. PERMIT PAID UNDER  17041-10002-34944	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71178	17041-10000-28734	1516 N SAN PABLO ST	90033	14	135A225    64	5202004042	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM			PC Info Complete	10/23/2017 12:00:00 AM	ADDRESS	34.06268	-118.20282	PC for T24 only for restuarant TI. Load under 400A. Installing new kitchen equipment, receptacles and lgihts. Building PC 17016-10000-19588. Total affected area is 2347sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71179	16041-10001-21080	14710 W VINCENNES ST	91402	6	198B149   219	2650029002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2016 12:00:00 AM			PC Approved	08/11/2016 12:00:00 AM	ADDRESS	34.24015	-118.45417	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.0KWac.(34)MODULES-SUNPOWER SPR-E20-327(1) INVERTER-SMA SB5000TL-US-22(2)INVERTER-SMA SB3000TL-US-22	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71180	16041-10000-20512	2219 1/2 N PARKSIDE AVE	90031	1	138A227   240	5211013024	R3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	Yes	1991.20	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Expired	07/16/2018 12:00:00 AM	ADDRESS	34.07097	-118.20024	PV SYSTEM WITH CENTRAL INVERTER 3.8KW AC USING 10 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71181	14041-10000-03871	1420 W SEPULVEDA ST	90732	15	018B193   492	7452002014	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	33.74527	-118.30697	PV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. POWER OPTOMIZERS. ONE STORY. SYSTEM SIZE: 3.5 KW DC.(14) CANADIAN SOLAR # CS6P-250PX(14) SOLAREDGE OP300(1) SOLAREDGE SE3800A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71182	14041-10001-21990	1326 W 12TH ST	90015	1	127-5A205 103	5137030029	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.04459	-118.27272	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71183	17041-30000-26119	401 S DETROIT ST	90036	4	135B181   387	5508005028	[Q]R4-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Apartment			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.06671	-118.34524	Plan check for replace new fire alarm panel with existing fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71184	15041-20000-20889	1314 N BENTON WAY	90026	13	141A205    51	5424017004	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.08239	-118.26908	Plan check for PV roof mounted system. System size: 3.5kW with 14 modules and 14 micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71185	17041-10000-22450	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			07/05/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	33.77884	-118.29327	Power plan check.  INDUSTRIAL CANOPY FOR STORAGE TANKS. COMPLETELY CONSEALED. NEW PLUGS AND LIGHTS. T24 EXEMPT - INDUSTRIAL AREA.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71186	15041-10000-04576	7350 W MELROSE AVE A	90036	5	141B181   614	5526020001	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	PIN	34.08330039	-118.3499936	Title 24 plan check only.  Total area = 822 sq. ft.T.I. to existing restaraunt space including new lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71187	18041-20000-23592	434 N CROFT AVE	90048	5	141B173  1307	5514002036	R1V3-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Closed	02/16/2022 12:00:00 AM	ADDRESS	34.07916	-118.37407	Plan check for a PV1 roof-mounted PV system. System size is 7.8 kWac and consists of (34) micro-inverters, (34) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71188	15041-10000-27550	5837 S VILLAGE DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	33.97536	-118.41488	New apartment bldg. 4 story. 6 units. level one is ground level and  includes the parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71189	16041-10000-45250	860 E FLORENCE AVE 1-30	90001	9	102B209   108	6023003032	CM-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2395.01	Electrical	Electrical	Apartment			12/27/2016 12:00:00 AM	11/01/2017 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.97451	-118.25874	FULL PC FOR POWER AND ENERGY. NEW 4-STORY 28 UNIT APARTMENT BLDG WITH -1-LEVEL OF ABOVE GRADE PARKING. SCOPE INCLUDES A NEW 1000A 120/240 3 PHASE 4WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS, AND NEW LIGHTING. TOTAL AFFECTED IS 21207 SQ. FT. B#15010-70000-00199	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71190	19041-30000-42212	6430 W SUNSET BLVD 1225	90028	13	147A187   154	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.09782	-118.32979	Enegry PC Check only, scope of work includes new lighting and receptacles. Total sq. ft. 1220.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71191	15041-10002-14904	1050 S GRAND AVE	90015	14	127-5A207 294	5139010013	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM			Verifications in Progress	01/24/2017 12:00:00 AM	ADDRESS	34.04171	-118.26155	12/14/16Changes to an approved set of plans. All changes are clouded under delta 6. Changes include replacing oven loads and circuit breakers from 20A to 30A for apartment units, revising unit floor plans, and revising load calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71192	14041-20000-04476	12500 W BRANFORD ST	91352	6	201B165   107	2629001006	(Q)M2-EZ1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.24638	-118.40551	New FedEx maintenance building.  Plan check for power and energy.plan check for hazardous locationNote: The FedEx warehouse expansion is under 14041-20000-04471	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71193	14041-20000-12387	13242 N MISSION TIERRA WAY	91344	12	225B133   183	2601010029	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.31104	-118.50406	Roof mounted PV system with Enhphase microinverters, model M215-60-2LL-, system size 4.32KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71194	11041-20000-09794	601 S FIGUEROA ST #4500	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Approved	05/13/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	T.I. to existing high rise building.  Install general/emerngency lighting of 45th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71195	15041-20000-43145	13279 W VAN NUYS BLVD	91331	7	207B157   356	2619017031	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			12/22/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.26576	-118.42287	FULL PC. TI TO AN EXISTING DENTAL OFFICE TO ADD AND RELOCATE INTERIOR PARTITION WALLS IN EXAM ROOMS. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES IN EXAM, LAB, AND WAITING ROOMS. TOTAL AREA IS 1176 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71196	18041-20000-23789	6270 N PENFIELD AVE	91367	3	177B113   355	2153036021	RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.18464	-118.56742	PV1.  Install 13.32kW DC roof mounted grid tied PV system.  (37) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71197	14041-10000-26699	14618 W SYLVAN ST	91411	6	178-5A151 140	2241011005	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Apartment			09/26/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.18442	-118.45151	Plan fire alarm system 53 devices and 1 panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71198	15041-10000-31181	13439 W CHANDLER BLVD	91401	4	171B157    52	2344010018	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Expired	12/15/2017 12:00:00 AM	ADDRESS	34.16871	-118.4258	Installation of 16KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF SFD, PERMIT FEE WAVED DUE TO 2012 SENATE  # 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71199	15041-10000-13421	814 N MAJORCA PL	90049	11	138B141   201	4494003027	RS-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	10/11/2016 12:00:00 AM	ADDRESS	34.07521	-118.48067	PV 1, ROOF MOUNTED SYSTEM. 48 MODULES. TOTAL SIZE 13.7KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71200	14041-20000-23065	1456 N BRONSON AVE	90028	13	147A191   236	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/25/2014 12:00:00 AM		Permit Finaled	11/03/2014 12:00:00 AM	ADDRESS	34.09754	-118.31782	T24 ENERGY ONLY. NEW LIGHTING. TI OF MULTIPURPOSE ROOM. MEZ. LEVEL. APPROX 3000 SQ FT. CRA APPROVED FROM BUILDING PERMIT UNDER APPLICATION #14016-70000-01081.PER BUILDING SUBMITTAL, PLAN CHECK IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71201	10041-20000-09707	6420 W WILSHIRE BLVD 1st Floor	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/21/2010 12:00:00 AM			PC Approved	05/21/2010 12:00:00 AM	ADDRESS	34.06365	-118.36922	Cafe area remodeling. Lighting and power. This P/C is for energy only.permit was obtained on 10041-10000-08405 (5-05-10)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71202	14041-10000-00398	11601 W WILSHIRE BLVD 8TH FLOOR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. HIGH RISE .8TH FLOOR. 10,625 SQFT. NO WORK WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71203	16041-20001-43228	10420 W BURBANK BLVD	91601	2	174B177   604	2417009007	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM			PC Approved	02/06/2017 12:00:00 AM	ADDRESS	34.17198	-118.35852	Change of use from retail to massage parlor.  Plan check for energy.  1376 sq ft.  Permit originally issued under 16041-10000-43228 for (E) branch circuits with new loads.  Additional permit fees to capture cost difference between master permit scope of work versus loads and equipment indicated on plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71204	19041-20000-05578	9501 N CLYBOURN AVE	91352	6	198B173     7	2538012012	RE40-1-K-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1211.02	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM			Corrections Issued	02/21/2019 12:00:00 AM	ADDRESS	34.24188	-118.36898	PV1.  Installation of 14.75 kW DC roof mounted grid tied PV system.  (50) modules with (2) 7.6 kW rated string inverters with DC-DC converters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71205	14041-20001-30752	510 S NORMANDIE AVE 1-40	90020	10	135B197   812	5502018022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Apartment			11/05/2014 12:00:00 AM			PC Approved	12/03/2014 12:00:00 AM	ADDRESS	34.06494	-118.30016	EXPEDITE PER APPLICANT REQUEST[PV2Install roof-mounted solar array on Apartment building. Interconnect with 200A service (?).System size: 11.4kW. Grounded system.44 305W pv modules across 4 strings (11+11+11+11).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71206	13041-10002-02996	1900 S CENTRAL AVE	90011	9	120A211    84	5129003037	C1-1VL	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.02412	-118.25057	11/30/2016 Changes to an approved set of plan changes include new lighting fixtures for indoor and outdoor. Changes apply to delta 8 only, permit will be under original application. New single story restaurant building. Power and Energy (indoor and outdoor) full plan check. Service size: 800A. Indoor sqrft: 5,037. Outdoor sqrft: 44,250.Variance to separate fire alarm plans filed on 12/3/2013.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71207	13041-20000-22521	515 S FLOWER ST 32ND FLR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM	08/20/2013 12:00:00 AM		Permit Finaled	11/15/2013 12:00:00 AM	ADDRESS	34.05134	-118.25661	RENOVATION OF EXISTING OFFICES. NEW LIGHTING. PC FOR T24 ENERGY ONLY. TOTAL AREA 3735 SQFT. WORK DONE ON 32ND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71208	14041-10001-09973	13274 W FIJI WAY	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM			PC Approved	04/27/2014 12:00:00 AM	ADDRESS	33.97902	-118.43558	(((EXPEDITE FEES)))pv2 commercial rooftop. solar modules to be installed on new canopy. total of 60 modules. using 480V interconnection. interconnect to existing 300A service system size 15 kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71209	17041-10000-14942	9520 N TOPANGA CANYON BLVD	91311	12	201B101   490	2746018009	(Q)MR1-1, QMR1-1, [T][Q]MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24363	-118.60646	PC for energy only, Outdoor Title-24. Removing HID fixtures and replacing them with new LED ones. Area: 51,200 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71210	17041-10000-32664	100 S SAN PEDRO ST	90012	14	130-5A213 169	5161017035	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/12/2017 12:00:00 AM			PC Info Complete	11/17/2017 12:00:00 AM	ADDRESS	34.05008	-118.24084	PC FOR OFFICE/ BANK TI. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71211	12041-10000-08691	374 E IMPERIAL HWY	90061	15	087A207   296	6083005036	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Apartment			04/17/2012 12:00:00 AM	11/07/2012 12:00:00 AM		Permit Expired	12/03/2014 12:00:00 AM	ADDRESS	33.93089	-118.2669	PLAN CHECK NEW 20.5KW ROOF MOUNTED AND GROUND MOUNTED PHOTOVOLTAIC SYSTEM FOR APARTMENT BUILDING. EXISTING SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71212	14041-20000-18183	19112 W HALSTED ST	91324	12	201B121   669	2762010019	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.24457	-118.54995	PV1Microinverter standard plan.Install roof-mounted solar array on SFD. System size: 3.87kW(18) EnPhase M215 IG microvinverters(18) Solar World SW250 Poly pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71213	16041-20000-06264	19200 W BALLINGER ST	91324	12	201B117   649	2762011012	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Expired	05/04/2018 12:00:00 AM	ADDRESS	34.2438	-118.55175	$0 permit fee due to State Senate Bill SB1222.  (((Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 175A.System size: 6.6kW (3+3.6). Ungrounded system. (33) 260W pv modules.)))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71214	15041-20000-37148	18250 W ROSCOE BLVD SUITE 230	91325	12	192B125   681	2102022034	C1-1VL, R1P-1VL	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.22064	-118.53113	FULL PC. TI FOR AN  OUTPATIENT MEDICAL OFFICE. CHECKING FOR OSHPD 3. SCOPE INCLUDES NEW LIGHTING, AND TWO NEW PANELS. TOTAL AREA IS 3780 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71215	12041-10000-23292	13550 W VAUGHN ST	91331	7	213B157   643	2523022001	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	PIN	34.2777765	-118.42734448	Plan check for new 4.6KW roof mounted photovoltaic system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71216	15041-10001-30338	9619 W MONTE MAR DR	90035	5	129B165   565	4306012011	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM			PC Approved	10/23/2015 12:00:00 AM	ADDRESS	34.04944	-118.39765	Expedited per customer request. (((PV1. Installation of a roof  mounted solar system interconnected with the main panel for a single family home. Scope of work: (1) inverter : 7.6 kw , (1) 125 Load center , (32) modules.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71217	13041-10000-31046	1010 S CROCKER ST	90021	14	124-5A211 262	5132010050	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.03433	-118.25052	PLAN CHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  1456 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71218	14041-20000-00051	20636 W AETNA ST	91367	3	177B109     2	2149010044	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.17872	-118.58307	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN WITH POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71219	17041-20000-10422	15928 W VENTURA BLVD #103-104	91436	5	168B141   621	2283010033	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	ADDRESS	34.15566	-118.48041	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a change of use from retail to massage parlor/tenant improvement. Total lighting area = 1,391 sq. ft.Note: Building permit has been pulled under 17016-10000-00658	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71220	17041-10000-44220	19441 W BUSINESS CENTER DR	91324	12	195B117    39	2783025099	MR2-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.23152	-118.5573	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71221	12041-10000-20891	901 E 12TH ST	90021	14	123A211    87	5132014001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/04/2012 12:00:00 AM			PC Info Complete	05/24/2013 12:00:00 AM	ADDRESS	34.03208	-118.24959	Plan check power and energy. New 4 story commercial building (future retail spaces and parking) 2000A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71222	13041-20000-16872	945 S BEACON AVE	90015	1	130-5A203 297	5137001027	R4-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.05018	-118.27527	New 30.38 kw Photovoltaic system with 105 modules and 4 inverters.  Commercial rooftop mounted. disconnect short circuit rating shall match 22k for all switches. solar subpanel rating is approved at 400A. permit includes main service and panel upgrade to 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71223	19041-10000-07921	804 S SAN PEDRO ST	90014	14	126A211   378	5146025039	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/05/2019 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.03814	-118.24917	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURE TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71224	17041-10000-29438	12900 W SHERMAN WAY	91605	2	183B161    47	2327018072	C2-1VL, P-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.20092	-118.41398	REMOVE EXISTING (12) HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 10075 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71225	10041-10000-09559	8440 W BEVERLY BLVD	90048	5	138B173   494	5511013001	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	11/23/2010 12:00:00 AM	ADDRESS	34.07579	-118.37464	INSTALLATION OF A METHANE MITIGATION SYSTEM AT A TACO BELL RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71226	15041-10001-38821	7270 W MANCHESTER AVE # 10	90045	11	096B157   625	4119026044	(T)(Q)RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM			PC Info Complete	03/14/2017 12:00:00 AM	ADDRESS	33.95959	-118.42143	CHANGES TO AN APPROVED SET OF PLANS FOR A FIRST TENANT-RESTAURANT. CHANGES INCLUDE REVISING FLOOR PLANS, ADDING ONE NEW WATER HEATER, RELOCATING LIGHTING FIXTURES, AND REVISING TITLE 24 FORMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71227	15041-20000-04586	20131 W PRAIRIE ST	91311	12	198B113   121	2748038033	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	02/04/2016 12:00:00 AM	ADDRESS	34.2394	-118.57264	TI TO AN EXSTING OFFICE COMMERCIAL BUILDING.  NEW STANDBY EQUIPMENT, PANELS, TRANSFORMERS AND CIRCUITS.  SCOPE OF WORK TO BE PERFORMED IN FIRST SECOND AND THIRD FLOOR.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 32225.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71228	18041-20000-23144	8338 W 3RD ST	90048	5	138B173   876	5511031030	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	02/21/2019 12:00:00 AM	ADDRESS	34.07268	-118.37138	Plan check for a fire alarm system for a commercial building. Fire alarm system consists of (1) FACP, (1) annunciator, and (19) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71229	17041-20001-22099	23116 W BIGLER ST	91364	3	171B097  1051	2074023003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2017 12:00:00 AM			PC Approved	07/21/2017 12:00:00 AM	ADDRESS	34.16102	-118.62962	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv array, roof-mounted on SFD.4.8kW ungrounded system.(20) EnPhase M250 microinverters.(20) 305W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71230	14041-20001-15307	432 S CITRUS AVE	90036	4	135B185   320	5507013018	R1-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.06585	-118.33954	PLAN CHECK FOR CHANGE FROM PREVIOUS APPROVED PLAN. DOWNSIZE MAIN BREAKER FROM 200A TO 175AMP.  NOTE:PERMIT IS UNDER ORIGINAL APPLICATION.PLAN CHECK FEE IS ZERO DOLLARS DUE TO BILL 122 FROM 2012.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71231	18041-20000-14237	19851 W SPLIT OAK RD	91311	12	210B113   240	2708028023	(Q)RE20-1-H	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM	04/18/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.27078	-118.56586	PV1.  Install 6.03 kW roof mounted grid tied PV system.  (18) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71232	17041-20000-10115	5410 W WILSHIRE BLVD 9th Floor	90036	4	132B181    16	5089003008	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Approved	03/29/2017 12:00:00 AM	ADDRESS	34.06204	-118.34668	TI to (E) commercial office space in a highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71233	14041-20000-29360	5366 N TOPANGA CANYON BLVD	91364	3	171B101   241	2169003002	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.16787	-118.60555	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT. BARBER SHOP. 1480 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71234	13041-10000-13037	777 S CENTRAL AVE	90021	14	124-5A213 395	5146007005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	04/22/2014 12:00:00 AM	ADDRESS	34.03464	-118.24302	pc for power and energy. no panel schedule so applicant provided estimate for fees (applicant brought panel schedule on 5/28/13 and it has been added to the plans). non-hazardouse per applicant. Methane Buffer Zone . new 2x 400A 480/277 svc. 2 stories. NEW retail/WAREHOUSE with offices. 2-STORY TYPE II CONSTRUCTION. FULLY SPRINKLERED WITH NFPA-13.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71235	11041-10000-24899	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM	02/03/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	ADDRESS	34.07417	-118.26931	T.I. to an existing mixed use high rise building on 8th, 9th, 12th, 14th, and 15th floors.  New circuits, transformers, equipment, and panels.   Plan check power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71236	15041-20000-21777	1607 W WILSHIRE BLVD	90017	1	132A205   392	5142009035	C2-2, C4-2, R4P-2, R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	08/27/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.0557	-118.27042	Title 24 plan check only.  Total area = 1,120 sq. ft.  T.I. to existing retail space (Yogurtland).  New lighting, recepticles, and plug loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71237	13041-10001-15019	18131 W VENTURA BLVD	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			01/27/2016 12:00:00 AM			PC Info Complete	01/27/2016 12:00:00 AM	ADDRESS	34.16596	-118.52824	** Supplemental PC and Permit to 13041-10000-15019: adding 3 sump pumps.*see contact for more info.pc for power and energy. NEW 4-STORY AND 2-LEVEL SUBT. GARAGE 196893SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71238	10041-10000-14357	210 W 5TH ST	90013	14	129A211   112	5149034006	C5-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			07/26/2010 12:00:00 AM	07/27/2010 12:00:00 AM		Permit Finaled	12/27/2010 12:00:00 AM	ADDRESS	34.04754	-118.25015	tenant improvement in the TWO BITS MARKETplan chk is fo rtitle 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71239	18041-20000-12225	4322 N GENTRY AVE	91604	2	165B165   573	2368009015	[Q]RD1.5-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Apartment			04/04/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM	ADDRESS	34.14929	-118.39304	Plan check for power and energy for new condos 10 units 2 story building. Total area: 8,867 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71240	12041-10000-23206	23740 W VANOWEN ST	91307	3	180B093    69	2034001012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2012 12:00:00 AM	11/06/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.19307	-118.64412	PLAN CHECK ROOF MOUNTED 4.8KW DC PHOTOVOLTAIC SYSTEM USING ENPHASE M215 MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71241	16041-10000-23590	3686 E OLYMPIC BLVD	90023	14	118-5A227 222	5191025012	M2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			07/06/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.01867	-118.19685	Installation of solar system in a commercial site, roof mounted. Installing three different inverter systems. System 1: (4) Central inverters rated at 33.3 kW (SOLAR EDGE, SE33.3KUS) each for a total size of 133.2 kW.  Installing 528 solar modueles. Note: System 2 and System 3 will be plan checked  under seperate permits.System 2 app # 16041-10000-23599System 3 app # 16041-10000-23604	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71242	18041-20000-25855	19519 W ROSCOE BLVD	91324	12	192B117   729	2783009009	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.22064	-118.5584	"Plan check for power and energy for ""A"" Occupancy. New Church/house of Worship Building. Total indoor and outdoor area: 24,512 sq ft. 400A ServiceB#16014-20000-06238"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71243	17041-30000-19806	10561 N VASSAR AVE	91311	12	207B101   147	2722011026	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	34.26256	-118.60557	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (16) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71244	16041-10000-01644	2049 S CENTURY PARK EAST S330	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	T-24, TENANT IMPROVEMENT TO (E) OFFICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT.  2490 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71245	13041-20001-19249	21700 W OXNARD ST SUITE 1950	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM			PC Approved	11/08/2013 12:00:00 AM	ADDRESS	34.17901	-118.60179	((Changes made to approved set of plans. Changing some fixtures to LED.))T24 FOR EXISTING OFFICE SPACE IN A HIGHRISE. SCOPE OF WORK ON SUITE 1950. TOTAL SQRFT 8749.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71246	12041-20000-21863	12131 W BURBANK BLVD	91607	2	174B165   722	2340025035	R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Approved	09/14/2012 12:00:00 AM	ADDRESS	34.17236	-118.39764	T-24 energy plan check for CHANGE OF USE FROM SINGLE FAMILY DWELLING TO CHILD DAYCARE CENTER W/ 20 CHILDREN MAX. PER P/ZC 2002-014.  THREE CLASS RMS TOTAL  (NONE-STRUCT INT REMODEL). SEE COMMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71247	19041-10000-22596	13237 W GARBER ST	91331	7	204B157   764	2623004008	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.25503	-118.42127	PV1 roof mounted system. Scope of work is 12 modules (Candian Solar 305 Watt) with optimizers (SE P320), and a central inverter (SE3800H-US). System size is 3.8KWac/3.66KWdc	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71248	10041-10001-18263	6150 W CENTURY BLVD	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Info Complete	08/11/2011 12:00:00 AM	ADDRESS	33.94474	-118.39224	"Modification to an existing approved set of plans.  Modification is to the existing hangar door.  Approved set of plans to be submitted.  <<<<<TI IN AN EXISTING OFFICE AREA AND HANGER AT LAX FOR ""RATHEON"" (ADJACENT TO DELTA HANGER).  PLAN CHECK IS FOR POWER AND ENERGY.>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71249	10041-10000-02330	1700 W SUNSET BLVD	90026	13	139-5A209 152	5404017020	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM	02/10/2010 12:00:00 AM		Permit Finaled	04/21/2010 12:00:00 AM	ADDRESS	34.0771	-118.25863	TI in an existing building. Plan Check is for title 24 Calcs and emergency lights. Permit is for new circuits and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71250	16041-10000-22730	1216 E 43RD ST	90011	9	114A211   351	5115032027	R2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2282.20	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2016 12:00:00 AM	07/11/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.00562	-118.2537	PV1 roof mounted solar system installation to a single family. Installing 16 microinverters rated at 215 watts. Total size of system = 3.44 kw	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71251	11041-10000-15949	3470 S MCCLINTOCK AVE CINEMATIC-ARTS	90089	8	120A201    44	5039012030	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.0236	-118.28768	NEW 3-STORY WITH BASEMENT ACADEMIC BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71252	15041-20002-10100	1454 W 66TH ST	90047	8	102B193   250	6015016014	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.02	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2015 12:00:00 AM			PC Approved	05/06/2015 12:00:00 AM	ADDRESS	33.97904	-118.30206	5/5/2015 Changes to an approved set of plans. Changes are to PV module layout and number of modules on each string. System size has remained the same.*****Previous Work Description*****Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (22) modules. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71253	18041-10000-41569	11055 W BURBANK BLVD	91601	2	174B173  1381	2337029028	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1242.04	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	02/05/2020 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.17235	-118.37235	T-24, PC FOR ENERGY ONLY. Tenant Improvement to existing restaurant. Scope includes new light and receptacles. Total affected area is 2143 B#18016-10000-35160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71254	10041-10000-16571	1221 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.05161	-118.22635	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71255	17041-20000-45363	19821 W FALCON CREST CT	91326	12	217-5A115 155	2701018026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2017 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.29071	-118.56524	PV1.  Install 12.1 kW DC roof mounted grid tied PV system.  (40) modules with 10kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71256	15041-20001-31731	17915 W BURTON ST	91335	12	192B129   415	2101019017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM			PC Approved	10/03/2015 12:00:00 AM	ADDRESS	34.22015	-118.52343	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. A new system is being added to an existing system. New system size is 3 kWac. Total system size is 6.8 kWac. New system consists of (1) inverter, (15) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71257	15041-20001-41317	13266 N MISSION TIERRA WAY	91344	12	225B133   173	2601010023	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	01/11/2016 12:00:00 AM	ADDRESS	34.31117	-118.50281	NOTE: FEES ARE $0 DUE TO DEPARTMENTAL ERROR. supplemental to change work description to read: PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.60KWac. (31)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-FRONIUS PRIMO 7.6	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71258	19041-20000-51165	22300 W MULHOLLAND DR	91364	3	165B101   186	2173001015	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	06/19/2020 12:00:00 AM	ADDRESS	34.14916	-118.61059	TENANT IMPROVEMENT ADD NEW LIGHTING FIXTURES AND EQUIPMENTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71259	14041-20000-01636	16501 W VENTURA BLVD #101	91436	5	168B137   337	2259018019	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.1578	-118.49275	ENERGY PLAN CHECK # 101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71260	17041-20001-45762	14101 W PIERCE ST	91331	6	201B153   465	2644005032	RS-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.24748	-118.44057	expeditepv1install roof mounted pv system sized 6.6kw with battery back up interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71261	14041-20000-19819	20780 W NORDHOFF ST	91311	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.23523	-118.58692	Plan check for power and energy. Brand new El Pollo Restaurant building (from ground up).per building submittal, PC for building efficiency standards according to 2008 code cycle.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71262	10041-20000-04525	8955 N ORION AVE 1-32	91343	7	195B141   186	2654001052	(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills			1174.05	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM	04/01/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	ADDRESS	34.23341	-118.47234	solar system in apartment building 32 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71263	13041-20001-08112	1542 N TOWER GROVE DR	90210	5	147B157   255	4356019012	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/16/2013 12:00:00 AM		Permit Expired	11/11/2015 12:00:00 AM	ADDRESS	34.09821	-118.42574	((((((CHANGES MADE TO APPROVED SET. ADDED ONE NEW PANEL FOR FUTURE POND. RELOCATED ATS THEREFOR SEVERAL FEEDER SIZES AND LENGTHS ALONG WITH THE VD% AND FAULT CURRENT CALCS HAVE CHANGES. ))))))Addition to a single family dwelling.  Upgrade the electrical service to 800A.  Install new main switchboard, subpanels, and branch circuits.  Install new 100KW Optional Standby Generator.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71264	19041-20000-12667	1006 N CHANTILLY ROAD	90077	5	144B149   264	4369036011	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	06/17/2019 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.08957	-118.45467	Plan check for Tesla battery back up system installed into existing PV. Install 2 Tesla Power Wall 2.0 13.5KWh, Total battery back up 27KWh connected to existing 600A service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71265	15041-20001-18154	7647 N ETON AVE	91304	3	186B105    68	2109031004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM			PC Approved	06/21/2015 12:00:00 AM	ADDRESS	34.20959	-118.59573	Expedite per customer request.PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (23) LG280 Modules(1) PVI-6000 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71266	10041-20000-19985	1550 W MANCHESTER AVE	90047	8	097-5A195 309	6037001050	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00, 2384.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	10/07/2010 12:00:00 AM		Permit Finaled	02/11/2011 12:00:00 AM	ADDRESS	33.95982	-118.30433	New fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71267	14041-20000-17393	21600 W OXNARD ST suite 600	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for energy only. New lighting (incl. emergency) on 6th floor of existing high rise office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71268	13041-10001-26010	12855 W RUNWAY ROAD BLOCK 1	90094	11	102B157   395	4211033036	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/23/2015 12:00:00 AM			PC Approved	04/03/2015 12:00:00 AM	ADDRESS	33.97556	-118.41956	REVISIONS TO PERMITTED SET OF PLANS: REVISED DRAWINGSHAVE ALL CHAANGES CLOUDED; 2 NEW PANELS WITH ADDED CKTS; MOST OF THE CHANGES INCLUDE RELOCATING SOME LUMINAIRES AND RECEPTACLE OUTLETS; CHANGING SERVICE LATERALS AND ELEV FEEDERS TO CU CONDUCTORS. PERMIT TO BE OBTAINED ON INSPECTION FEE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71269	14041-20000-23732	3343 S MOUNTAIN VIEW AVE	90066	11	117B153   983	4248018008	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.01424	-118.43744	PV1.  Install 5.2 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71270	14041-20000-24221	13001 N MESA VERDE WAY	91342	7	228B161   360	2580001001	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM	09/05/2014 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.30827	-118.4071	PV1.  Install 5.4 kW roof-mounted, utility-interactive PV system.STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71271	17041-20000-41504	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.28583	-118.51165	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.145 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71272	18041-10001-18621	5151 W HOLLYWOOD BLVD	90027	13	148-5A195  88	5544011021	C2-1D	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM			PC Approved	01/07/2019 12:00:00 AM	ADDRESS	34.10192	-118.30232	SUPPLEMENTAL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE UPDATE OF LIGHTING PLAN/FIXTURE SCHEDULE - DELTA #3 ONLY- ORIGINAL PERMIT PC FOR Tenant Improvement IN EXISTING RESTAURANT FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA  1678 SQ.FTSCOPE OF WORK INCLUDES NEW CIRCUITS, RECEPTACLES AND LIGHTS. B#18016-10000-11608	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71273	18041-10000-09971	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM			PC Approved	03/19/2018 12:00:00 AM	ADDRESS	34.12626	-118.21412	THE PROPOSED PROJECT CONSISTS OF non-sales 347 SF OUTDOOR, LATTICE-ROOF LOUNGE AREAPlan check is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71274	14041-10000-32963	2221 S LINCOLN BLVD	90291	11	108B149   343	4241034024	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM			PC Approved	12/04/2014 12:00:00 AM	ADDRESS	33.99467	-118.45449	Energy plan check for office T.I.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71275	13041-10001-16723	3553 E BESWICK ST	90023	14	120A227   144	5191012031	(T)(Q)RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Apartment			02/20/2014 12:00:00 AM			PC Approved	02/20/2014 12:00:00 AM	ADDRESS	34.02223	-118.19931	CHANGES TO APPROVED SET. CHANGES IN LOCATION OF 4 FIRE ALARM DEVICES. DELTA 1 CHANGES ONLY.installation of fire warning system with central station monitoring	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71276	18041-20000-04596	3867 N CORBIN AVE	91356	3	162B117   237	2180019006	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.14012	-118.56443	Plan check for the addition of a battery back-up system to an existing PV1 roof-mounted PV system. Submitted per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71277	16041-10002-01429	4619 N ALGER ST	90039	13	159B205    51	5593021008	MR1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/11/2017 12:00:00 AM			PC Approved	08/11/2017 12:00:00 AM	ADDRESS	34.13573	-118.26703	PC FOR TITLE 24 ENERGY ONLY FOR AN OFFICE AND WAREHOUSE.TOTAL AFECTED AREA 7501 SQ.FT. PERMIT PULLED UNDER ORIGINAL APPLICATION.THIS IS PLAN CHECK ONLY!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71278	19041-20001-37606	1907 N NOLDEN ST	90041	14	159A229   206	5480029020	RE11-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.12986	-118.19405	12-11-2019 Changes to an approved set of plan, Changes include remove DC Disconnects and relocate inverters and PV disconnects. All changes has been clouded.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71279	19041-10000-15870	3640 S HOLDREGE AVE	90016	10	117B173    71	4204008015	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	07/15/2019 12:00:00 AM	ADDRESS	34.01993	-118.37802	INSTALL 131 NEW FIRE ALARM DEVICES AND 1 PANEL IN SINGLE STORY BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71280	18041-20001-37991	14062 N BALBOA BLVD	91342	7	228B137   186	2603007027	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM			PC Approved	05/07/2019 12:00:00 AM	ADDRESS	34.32065	-118.4882	$0 PLAN CHECK FEE  DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CLOUDED CHANGES ONLY. CHANGE TO SINGLE LINE DIAGRAM, ADDING AC DISCONNECTS TO EACH INVERTER, AND CHANGES TO EQUIPMENT AIC RATINGS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71281	19041-20001-42986	5510 S LINCOLN BLVD STE 450	90094	11	102B157   355	4211022023	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM			PC Approved	10/24/2019 12:00:00 AM	ADDRESS	33.97299	-118.43051	10-24-2019 Changes to an approved set of plan, Changes include additon of lighting fixture LF-10. All changes has been clouded as delta 1. Plan check only, permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71282	14041-20003-02277	17100 W CALAHAN ST PV1	91325	12	198B133   591	2692019030	RE9-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			03/19/2014 12:00:00 AM			PC Approved	03/19/2014 12:00:00 AM	ADDRESS	34.23631	-118.50588	(((3/19/2014- CHANGES MADE TO APPROVED SET OF PLANS. REMOVED GEC AND CHANGE CONDUIT CONFIGURATIONS. NO ADDITIONAL PERMIT FEES ARE REQUIRED, THIS IS A PLAN CHECK ONLY.)))pv1 single family dwelling. total system size 11.4 kw ac using 3 transformerless inverters nonstandard plan. using power optimizers. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71283	18041-10000-15661	3236 S STONER AVE	90066	11	117B153   387	4250006005	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.01835	-118.43636	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM CONSISTING OF 22AC MODULES (SPR-X22-360-AC)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71284	14041-10000-32778	1441 N BENEDICT CANYON DR	90210	5	147B157   328	4357006009	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.09731	-118.43066	PV1, INSTALL 14.776 KW AC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE, UPGRADING MAIN SERVICE PANEL TO NEW 225 A MAIN SERVICE. $0 fees are due to Senate Bill 1222(1)MICRO INVERTERS: ENPHASE M250-60-240-S22(60) MODULES: LG 280 G3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71285	12041-10000-12184	1055 E CESAR E CHAVEZ AVE	90033	14	130-5A219  28	5410008020	M1-2D	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			05/25/2012 12:00:00 AM			Corrections Issued	05/25/2012 12:00:00 AM	ADDRESS	34.05367	-118.22391	"New 1118sqft Auto repair facility. 200A single phase service. Plan check for energy and emergency lighting. 1118 unconditioned sqft + 3075 outdoor sqft = 4193 sqft total. PLANS WERE STAMPED BUT NOT APPROVED. CUSTOMER MUST APPLY FOR CHANGE OF USE, BUILDING IS CURRENTLY ""M"" OCCUPANCY WHILE CUSTOMER CLAIMS THAT BUILDING WILL BE USED FOR AUTO GLASS REPAIR."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71286	14041-10001-09008	12829 W GREENE AVE	90066	11	108B157  1643	4223015022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	06/11/2014 12:00:00 AM	ADDRESS	33.9882	-118.42942	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6.625 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTERS: SOLAREDGE SE6000A-US-ZB-U &(25) MODULES: SUNIVA OPT265-60-4-1B0}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71287	13041-10001-26350	6643 N RIVERTON AVE	91606	2	180B177    64	2414026045	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/17/2013 12:00:00 AM	ADDRESS	34.19154	-118.36608	][][]EXPEDITED PER APPLICANT REQUEST][][]PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH MAIN; WORK DONE ON A STANDARD PLAN ; COMBINER BOX USED. SYSTEM SIZE IS 6.75kW DC WITH (27) MODULES: TRINA #TSM-250PA05.18(1)FRONIUS #IG 5100 NEG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71288	15041-20000-32118	310 N GRAND AVE #B	90731	15	018B197   697	7448029***	R2-1XL	Harbor	San Pedro	Central San Pedro		2965.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	33.74533	-118.28994	PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING STANDARD PLAN. TOTAL OF 25 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71289	10041-10000-07198	1067 S FAIRFAX AVE	90035	5	132B177   910	5086001039	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			04/20/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	05/17/2010 12:00:00 AM	PIN	34.05632535	-118.36500991	iNSTALLATION OF NEW FIRE ALARM PANEL IN A SINGLE STORY BUILDING. 26 DEVICES AND 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71290	10041-20000-16630	12121 W WILSHIRE BLVD UNIT 1120	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	PIN	34.04391963	-118.46825257	TI IN OFFICE AREA. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71291	16041-10000-45534	3129 W SAN FERNANDO ROAD	90065	13	154-5A213 222	5458008014	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.11556	-118.24629	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71292	18041-10001-20324	7843 N LANKERSHIM BLVD Suite #200	91605	6	189B169   517	2310025034	C2-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.21329	-118.38805	DELTA 4 changes to an approved set  for a first time occupancy of a new office space in Suite #200 on the 2nd floor. T-24 changes, addition of two circuits for H-VAC equipment, and relocation of mechanical equipment. BULDING PERMIT # 16016-10000-30375	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71293	15041-20001-33464	7080 W HOLLYWOOD BLVD 7TH FLR	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	ADDRESS	34.10134	-118.34445	Revisions made to approved set to accommodate architectural layout changes and field changes to lighting fixture schedule.  (((T-24, PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES ON THE 7TH FLOOR. TOTAL AREA IS 12,672 SQ. FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71294	12041-20000-20735	23560 W LULL ST	91304	12	186B093   705	2027029049	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM			Reviewed by Supervisor	11/08/2012 12:00:00 AM	ADDRESS	34.20944	-118.64107	Plan check for PV. Single family dwelling. 14.79 KW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71295	15041-10000-39212	4551 S GLENCOE AVE SUITE 100	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	33.9844	-118.43407	TENANT IMPROVEMENT IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71296	18041-20000-05317	1250 N MONACO DR	90049	11	129B133   109	4407012003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.05209	-118.50039	Plan check for power only. Project site is a new 2-story single family dwelling. Work includes a new 600-amp service.Note: Building permit has been issued under 15010-40000-04260. Electrical permit fees have been paid under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71297	19041-30000-02121	5925 W 3RD ST	90036	5	135B181    76	5512019021	C1-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.06976	-118.34951	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 483 sq. ft.Note: Building permit has been issued under 17016-20000-02548	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71298	14041-20000-12685	515 S FIGUEROA ST 18th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI in a commercial highrise building restrooms on the 18th floor.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71299	13041-10001-28705	255 S HILL ST	90012	14	130-5A211  15	5149010264	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.05197	-118.24904	CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 3.   CHANGES INCLUDE RELOCATION OF EXISTING BRANCH CIRCUITS.   Renovation of Agape Center apartment complex common areas (5 stories).  Replace lighting in corridors and common areas.  Add receptacles for the new remodel changes.  Newly connected load in excess of 400A.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71300	19041-20000-34183	20601 W BLUEBIRD CT	91326	12	219B109     5	2701001054	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.29721	-118.58244	PV1 PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 5.25 KW DC/4.73 KW AC. SCOPE OF WORK CONSISTS OF (15) 15 MODULES WITH MICROINVERTERS AND A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71301	16041-20001-19188	19450 W SHERMAN WAY	91335	3	183B117    87	2130026003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1330.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM			PC Approved	06/29/2016 12:00:00 AM	ADDRESS	34.20088	-118.55725	Expedited per applicant request.Plan check for an addition of a PV1 roof-mounted PV system. Addition system size is 3 kWac for a total system size is 6 kWac. Addition consists of (1) inverter, (1) load center, and (14) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71302	14041-10000-05205	13114 W COMMUNITY ST	91352	6	192B161    50	2634027014	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.22323	-118.41848	PV1.  Install 3.5 kW DC roof-mounted solar array, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US-ZB-U.  15 modules: Trina Solar TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71303	17041-30000-16377	469 W 6TH ST	90731	15	015B197   390	7455005008	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/16/2017 12:00:00 AM			PC Info Complete	05/16/2017 12:00:00 AM	ADDRESS	33.73863	-118.28724	Plan check for Title 24 only in existing space T.I. retail due to fire damage. Total area: 598 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71304	18041-10001-47760	10311 S LA CIENEGA BLVD	90045	11	090B173   271	4129031001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	04/28/2021 12:00:00 AM	ADDRESS	33.94269	-118.37026	Power plan check for an auto repair garage. (Hazardous location). Upgrade service to 800A  120/240 3ph, panels, circuits and equipment. No changes to T-24.T-24 paid under master partial permit fees paid under master as well. Master scope: T-24 ONLY, REMODEL & CHG OF USE TO AUTO REPAIR GARAGE. SCOPE OF WORK INCLUDES NEW LIGHTING, PANELS AND RECEPTACLES. SERVICE SIZE IS 400AMPS, TOTAL SQ. FT. 9110	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71305	10041-20000-08578	7083 W HOLLYWOOD BLVD FL  2ND &-3RD	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM			PC Approved	05/10/2010 12:00:00 AM	ADDRESS	34.10173	-118.34439	TI FOR OFFICE AREA. LIGHTING AND POWER. THIS P/C IS FOR TITLE 24 ENERGY ONLY. PERMIT ALREADY OBTAINED IN 10041-90000-06576.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71306	14041-10001-32778	1441 N BENEDICT CANYON DR	90210	5	147B157   328	4357006009	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2014 12:00:00 AM			PC Approved	12/22/2014 12:00:00 AM	ADDRESS	34.09731	-118.43066	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 14.776 KW AC ROOF-MOUNTED SOLAR ARRAY ON A HOUSE, UPGRADING MAIN SERVICE PANEL TO NEW 225 A MAIN SERVICE.(1)MICRO INVERTERS: ENPHASE M250-60-240-S22(60) MODULES: LG 280 G3>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71307	17041-10000-20491	1025 S WESTWOOD BLVD	90024	5	132B149    25	4363018028	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM			PC Info Complete	06/16/2017 12:00:00 AM	ADDRESS	34.06197	-118.44565	PC FOR OFFICE TI. TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND NEW ACTOTAL AFFECTED AREA 385 S.Q.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71308	15041-20001-01210	10338 N LINDLEY AVE	91326	12	204B125   120	2731010016	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.25844	-118.5272	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20.0KW INTERCONNECTED WITH MSP.THIS IS 1  PV DESIGN OF TWO.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71309	19041-10000-44407	10731 W ASHBY AVE	90064	5	126B157  1261	4255023016	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.0378	-118.42313	PV1, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND SOLAR OPTIMIZERS. (20) MODULES, (20) OPTIMIZERS, (1) 7600 SOLAR EDGE INVERTER. TOTAL SYSTEM SIZE IS 6.1 KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71310	14041-10000-00497	1458 S SAN PEDRO ST #L-38	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES TO REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS.673 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71311	15041-20001-23005	6220 N TOPANGA CANYON BLVD Space 9080	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	09-11-2015 Change to approved set of plans. Chnages includes split bus changes to 2 sub panels and rename the circuits to match the 2 new panels for disagregation. {{{{{Plan check for power and Title-24 (energy).  Total area = 300 sq. ft.  T.I. to commercial first time tenant.  New lighting and cooking equipment in existing kiosk.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71312	16041-20000-41123	515 S FLOWER ST Floors 48-49	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	06/05/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI to (E) commercial office space in commercial highrise office building.  Over 400 A of load @ 208V.  Plan check for power and energy.  33,000 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71313	19041-30000-48988	601 S FIGUEROA ST STE 3850	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	01/16/2020 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING AND CIRCUIT LOAD. TOTAL SQ. FT. FOR ENERGY: 2070.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71314	13041-10000-12380	7260 W HAWTHORN AVE 1-25	90046	4	147B181   443	5548010018	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			05/13/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	12/15/2014 12:00:00 AM	ADDRESS	34.0996	-118.34834	PLAN CHECK FOR NEW 4-STORY, 25 UNITS APARTMENT BUILDING OVER SUBTERRANEAN GARAGE. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71315	19041-10000-01635	10316-10322 N SEPULVEDA BLVD	91345	7	204B145   250	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM	01/15/2019 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.25783	-118.46706	NEW FIRE ALARM SYSTEM FOR 1-STORY COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES 1 FA PANEL AND 27 FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71316	17041-10000-27267	11203 N GLENOAKS BLVD #1	91331	7	210B161   226	2533018004	[Q]C2-1VL-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.27378	-118.41205	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY TOTAL 4800 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71317	13041-10000-35424	922 N FORMOSA AVE	90046	5	144B181   726	5531016006	[Q]MR1-2D	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			12/19/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.08774	-118.3461	PLAN CHECK FOR T24 ONLY. AREA 2971 SQ FT. TI FOR SINGLE STORY EXISTING OFFICE. ELECTRICAL PERMIT IS ISSUED PER APPLICATION # 13041-10000-33754.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71318	16041-10000-21993	840 E 111TH PL	90059	8	088-5A209 259	6071022005	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Closed	09/18/2023 12:00:00 AM	ADDRESS	33.93546	-118.25949	Full PC. Repair of a vandalized wherehouse New service of 1000 Amps UG pull section, (1) new panel rated at 200 amps and (1) subpanel rated at 125 amps. Total sqft = 28251.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71319	19041-20000-37137	11408 W ALBATA ST	90049	11	135B145   685	4365017002	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.06362	-118.4613	Installation of 13.5 kWh energy storage system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71320	14041-20009-17303	5800 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			02/08/2017 12:00:00 AM			PC Approved	02/08/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	02/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 19. Changes include the relocation of an exhaust fan on the single line diagram and the addition of a third elevator to the generator loads.01/13/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 18. Changes include the addition of a transformer and subpanel for EV chargers.12/08/2016 Changes to approved set.  Delta-17 changes: miscellaneous revisons to mechanical equipment ratings and connection points - feed cooling tower spray pumps from panel 14LA.10/18/2016 Changes to an approved set of plans. Changes have been made to the OCPD of the EM generator. All changes have been clouded.9.1.2016 - Plan check for changes to approved set. Update panel schedules and floor plans to reflect as built conditions. Removing first floor lobby lighting from scope of project. Changes clouded delta 15.8/18/2016Plan check for changes to approved set.  Add series rating for LA panels. Add insulated ground conductor for flex conduit.  Revised various mechanical equipment. Changes clouded delta-14. 6/11/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 2 and Delta 3. Changes include downsizing the EM generator to 800 kW from 1000 kW, the EM distribution board has been separated to have sections, 10 new lighting control panels, the addition of 2 new civil sump pumps, addition of fire smoke damper circuits, relocation of additional circuits and upsizing of water heater circuit breakers. *****Previous Work Description*****A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71321	12041-10005-05668	1340 S FIGUEROA ST	90015	14	126A205    86	5134010016	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM			PC Approved	03/04/2014 12:00:00 AM	ADDRESS	34.03951	-118.26852	plan check only. Plan check for Energy only. residential control requirements per inspector request for apartment units. revisions to permitted set of plans (FY)NEW MIXED USE 171 UNIT APARTMENT COMPLEX, 7 STORIES WITH SUBTERRANEAN PARKING. PLAN CHECK POWER AND ENERGY. TWO SERVICES SUPPLYING BUILDING. METHANE ZONE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71322	14041-10000-09078	12740 W GAULT ST	91605	2	183B161   279	2324018084	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Expired	04/29/2016 12:00:00 AM	ADDRESS	34.19924	-118.41096	PV1 6.5KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(1) inverters: {PVI-6000-OUTD-US}]. [(26)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71323	17041-10002-42332	5971 W VENICE BLVD 2ND & 3RD-FLOORS	90034	10	126B173   912	5066003021	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM			PC Approved	08/24/2018 12:00:00 AM	ADDRESS	34.03865	-118.37272	PC FOR CHANGES TO APPROVED SET (MEDICAL OFFICES) UNDER DELTA 1. THIS IS FOR ADDITIONAL SCOPE TO 10001 SUPP. NEW ADDED SCOPE INCLUDES WORK DONE IN EXAM ROOMS FOR POWER MINOR CHANGES TO LIGHTS AND T-24.THIS IS PLAN CHECK ONLY! PERMIT FEES FOR THIS SCOPE TO BE PAID UNDER 10001*****SEE NOTES****** TENANT IMPROVEMENT: INTERIOR REMODEL ; FULL PLAN CHECK ON FLOORS 2 AND 3 OF EXISTING CLINICAL SPACE (MEDICAL OFFICE) NO HOSPITAL.NEW PANELBOARDS AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71324	15041-10000-26880	200 WORLD WAY TERM 2-DEPT LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/17/2015 12:00:00 AM			PC Approved	08/17/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	"TENANT IMPROVEMENT IN CONCESSION STORE AT LAXTERMINAL 2 DEPT  LEV 1  SPACE 226PLAN CHK IS FOR TITLE 24 by adding fixture "" F5 "" in addition to the newly approved permit."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71325	13041-10001-22485	11040 W PICO BLVD	90064	5	126B153  1136	4256008014	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.03753	-118.43352	][][CHANGES MADE TO FIRST SUBMITTAL PLANS; CHANGES IS TO COVER THE FOLLOWING: 1)TITLE-24, 2) DELTA-1 CHANGES TO THE MASTER PLAN, ][][][PC FOR POWER AND ENERGY. TI TO (E) RETAIL.  99c STORE FULL TENANT IMPROVEMENT. 1000A service. previously a furniture store. not a methane zone. WITH PARKING LOT RE-STRIPING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71326	18041-10000-37986	21055 W VENTURA BLVD 1-4	91364	3	171B105   112	2167001011	(T)(Q)C4-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.16706	-118.59245	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES RETROFIT KIT REPLACEMENT TO LED LIGHTING. EXISTING WIRING AND CIRCUITS. TOTAL SQ. FT. 16,577.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71327	11041-20000-22608	13561 W VAN NUYS BLVD	91331	7	207B157   989	2619026006	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM			PC Approved	10/21/2011 12:00:00 AM	ADDRESS	34.26147	-118.42883	T.I.  Remodel of the light fixtures in a restaurant space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71328	18041-10000-33948	600 S STATE DR	90007	9	118-5A201 122	5037028908	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Issued	09/06/2018 12:00:00 AM	ADDRESS	34.01709	-118.28301	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71329	15041-20000-17375	1801 CENTURY PARK EAST 6th Floor	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	PIN	34.0621869	-118.41581732	Plan check for Title 24 only. Project site is the 6th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area  = 13,007 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71330	11041-10000-24009	1058 S VERMONT AVE	90006	1	129B197   433	5076009016	C2-1, R4-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	02/01/2012 12:00:00 AM		Permit Finaled	08/20/2012 12:00:00 AM	ADDRESS	34.05114	-118.29143	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71331	13041-20000-03495	19724 W NORDHOFF PL	91311	12	195B117     3	2761001034	(T)P-1, MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM			Corrections Issued	02/11/2013 12:00:00 AM	ADDRESS	34.23531	-118.56378	Plan check for energy only. Indoor and outdoor lighting. Olive Garden. Emergency lighting is existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71332	10041-10001-11371	14309 W BURBANK BLVD Parking-Lift	91401	2	174B153   754	2245010051	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Apartment			03/31/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.1723	-118.44467	Automated Parking Lift for a 8-unit apartment building.  <<<<<The Apartment portion is checked under 10041-20000-11371>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71333	15041-20000-29183	317 S BROADWAY	90013	14	130-5A211  88	5149015025	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			PC Info Complete	09/24/2015 12:00:00 AM	ADDRESS	34.05069	-118.24861	TI for a restaurant. PC for energy only. Total area 584 sq. ft**** corrected total area after verification is about 800sq.ft.  refer to plan for accurate number****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71334	15041-30000-43514	838 N HUDSON AVE 1-8	90038	4	141B185    87	5533026015	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.08643	-118.33194	Installation of new fire alarm system in new 11 unit 4 story apartment building.  Total system size = 52 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71335	11041-10000-27680	1835 S SEPULVEDA BLVD	90025	5	126B153   135	4323026019	M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			12/30/2011 12:00:00 AM	03/13/2012 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.04494	-118.44233	"TI to convert Fitness to Office & laundry. EPC is for T24 & lighting in office are.""COMPLY WITH DEPARTMENT ORDER effective date01/03/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71336	18041-10000-05192	2595 S HOOVER ST	90007	8	123A201    42	5055022036	C4-1VL-O, QC1.5-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.03206	-118.28429	FIRST TENANT-RESTAURANT- IN RETAIL SPACE# 17016-10000-37861	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71337	19041-10000-48067	8844 S VERMONT AVE	90044	8	096A199   188	6038012010	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	33.95704	-118.29137	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71338	18041-20001-22646	8564 W HILLSIDE AVE	90069	4	148-5A173 443	5558028015	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2018 12:00:00 AM			PC Approved	08/13/2018 12:00:00 AM	ADDRESS	34.09985	-118.37311	Revision to approved set of plans.  Change of inverter rating from 3.0 kW to 3.8 kW.  (((Plan check for PV roof mounted system, System size: 3.0kWac with 16 modules and 1 inverter(3.0.kW))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71339	19041-10000-20494	5016 S 8TH AVE	90043	8	111B189  1443	5014009004	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM	07/30/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	33.99717	-118.32564	PC FOR BATTER BACK UP  SYSTEM, SYSTEM CONSISTS OF 2 BATTERY, SIZE IS 12KWH EACH. SYSTEM IS INTERCONNECTING TO PV SYSTEM. PV SYSTEM HAS BEEN PAID FOR UNDER APPLICATION # 18041-90000-42610.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71340	19041-10000-48417	2932 S SOMERSET DR	90016	10	120B185   181	5050019024	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.02849	-118.33724	plan check for roof mounted pv1 systen consisting of 10 ac modules(sunpower a425) system size 3.49kva	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71341	19041-20000-20757	17600 W LEMARSH ST	91325	12	204B129   294	2734012018	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.25542	-118.51801	Plan check for PV roof mounted system, system size: 11.16KW DC, 10.54KW AC with 36 PV Modules and 36 microinverters connected to 225A panel with 200A main breaker.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71342	10041-20000-02620	5424 N LAUREL CANYON BLVD	91607	2	174B165  1012	2348014055	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			02/16/2010 12:00:00 AM	02/23/2010 12:00:00 AM		Permit Finaled	04/29/2010 12:00:00 AM	ADDRESS	34.16932	-118.3963	T.I WORK IN RETAIL STORE. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71343	14041-20000-05400	7233 N JAMIESON AVE	91335	3	186B129  1278	2121010009	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Expired	05/03/2016 12:00:00 AM	ADDRESS	34.2023	-118.52199	Roof mounted PV system with Optimizer, system size is 4.75 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71344	19041-20000-16172	12622 W VANOWEN ST	91605	2	180B161    39	2325002040	RD1.5-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1233.04	Electrical	Electrical	Apartment			05/01/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Permit Finaled	07/23/2021 12:00:00 AM	ADDRESS	34.19374	-118.40804	new fire alarm system 44devices and FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71345	19041-20000-44036	6626 N MATILIJA AVE	91405	2	180B153   463	2238011043	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.19119	-118.43331	PV1. INSTALL 2.17 KW AC SYSTEM WITH (7) MODULES AND MICROINVERTERS ON EXISTING PV SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71346	14041-20000-02285	16801 W SAN FERNANDO MISSION BLVD	91344	12	210B137   405	2682021006	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	03/06/2014 12:00:00 AM	ADDRESS	34.27215	-118.49829	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8KW AC UISNG 2 TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS. PERMIT HAS BEEN PULLED ALREADY. THIS IS A PLAN CHECK ONLY.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71347	16041-10000-22504	568 S ALAMEDA ST	90013	14	126A215   174	5164001009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.0396	-118.23809	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (WAREHOUSE). SCOPE INCLUDES REPLACING THE HID FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 7856 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71348	17041-20003-26760	18611 W BRYMER ST	91326	12	213B125   145	2872019031	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM			PC Approved	09/19/2017 12:00:00 AM	ADDRESS	34.28251	-118.5386	09/19/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. MSP has been upgraded from 200-amps to 225-amps.*****Previous Work Description*****Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 4.6 kWac and consists of (1) inverter and (17) modules. PV interconnection is being made onto a center-fed panelboard.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71349	13041-10000-09686	10 N UNIVERSAL CITY PLAZA # 1457	91608										Electrical	Electrical	Commercial			04/15/2013 12:00:00 AM			PC Approved	04/15/2013 12:00:00 AM				REMODELING A CONFERENCE ROOM  IN ROOM # 1457PLAN CHK IS FOR TITLE24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71350	19041-10000-24689	6869 N TUJUNGA AVE	91605	2	183B169   689	2320002011	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/06/2019 12:00:00 AM	ADDRESS	34.19579	-118.37923	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71351	14041-10000-12001	1149 S HILL ST Suite 465	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/13/2014 12:00:00 AM	ADDRESS	34.03926	-118.26099	TI TO EXISTING OFFICE SPACE. RECONNECTING TO EXISTING CIRCUITS. PLAN CHECK IS FOR ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71352	17041-20000-40969	3511 S BEETHOVEN ST	90066	11	114B149   895	4245006033	[Q]RD2-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.00593	-118.44608	Install 13.5 kWh energy storage system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71353	12041-10000-20490	10700 W SANTA MONICA BLVD SUITE #130	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			08/29/2012 12:00:00 AM	09/27/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.05167	-118.432	First time tenant for a comercial BLDG. EPC is for power & Energy. (suite# C)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71354	16041-20004-26751	10534 W SANTA MONICA BLVD 1-9	90025	5	132B157  1078	4317004016	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM			PC Info Complete	02/14/2019 12:00:00 AM	ADDRESS	34.05456	-118.42769	"02-14-2019 Changes to an approved set of plans, Changes include dedicated section for Fire pump. All changes has been clouded as delta ""F"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71355	17041-10000-39591	8097 W SELMA AVE	90046	4	147B173   218	5555030001	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.09832	-118.3669	PC for T24 only for change of use to restuarant. Installing new 400A service, three panels, receptacles and equipment. Total of 3005sqft. Installing less than 400A demand load(per Francis).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71356	16041-20000-27478	4750 N DEL MORENO PL	91364	3	168B113   317	2174003031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.15638	-118.57505	Plan check for PV roof mounted system. System size: 6.0kW with 29 modules and 1 inverter(6.0kW). Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71357	17041-10000-36524	454 N CUESTA WAY	90077	5	141B153    90	4362019004	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.08493	-118.44018	FOR A SFD, INSTALL A STANDBY GENERATOR AND ATS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71358	12041-20000-24479	6255 W SUNSET BLVD 22nd fl	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.09815	-118.32564	energy plan check  22nd floor, elevator lobby restrooms and hallways	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71359	14041-10000-16759	725 S FIGUEROA ST # 1870	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.04886	-118.26071	Tenant improvement in offices on 18th flplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71360	16041-20000-29020	5461 W JEFFERSON BLVD	90016	10	120B177   474	5048017040	OS-1XL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Issued	09/19/2016 12:00:00 AM	ADDRESS	34.02617	-118.36558	0$ permit fees due to senate bill 1222PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 96KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71361	13041-20000-14801	13275 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24 KW. 15 PANELS IN TOTAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71362	11041-10000-01485	805 W MANCHESTER AVE	90044	8	097-5A199 203	6032014023	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM			PC Approved	01/25/2011 12:00:00 AM	ADDRESS	33.96022	-118.28728	INTERIOR TI IN THE DINING ROOM AND RESTROOMS; PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71363	18041-10000-44451	11685 W VENTURA BLVD	91604	2	162B169   383	2368007006	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.14129	-118.38731	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71364	12041-10000-22432	734 N LA JOLLA AVE	90046	5	141B173   289	5528006006	R2-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	ADDRESS	34.08469	-118.36787	NEW 11.77 KW ROOF MOUNTED PV FOR A SINGLE FAMILY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71365	19041-10000-00247	715 W 41ST PL	90037	9	114A201    38	5019020009	RD1.5-1	South Los Angeles	South Los Angeles	Voices		2317.20	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.00793	-118.28634	Plan check for a PV1 8.32kw roof mounted system with (26) modules and microinverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71366	15041-10000-20675	17472 W VENTURA BLVD	91316	5	171B129   445	2290004025	C4-1VL, RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	08/21/2015 12:00:00 AM	ADDRESS	34.16129	-118.51394	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71367	14041-20000-10232	655 S HOPE ST #101	90017	14	129A209   262	5144006901	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.04849	-118.25759	Remodel for new restaurant on ground floor of existing commercial highrise building.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71368	15041-10000-06993	11269 N GLENOAKS BLVD	91331	7	210B161   118	2533017012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.27509	-118.4135	PV1.  Install 3.924 kW roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71369	13041-20000-10176	1800 S AVENUE OF THE STARS #800	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.06095	-118.41786	Change to lighting, receptacles, loads to an existing high-rise office building on three floors.  Load is less than 200 amps for work on all three floors per applicant.  Plan Check Only for Energy, with Emergency lighting for the 8th Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71370	19041-10000-12980	450 W OLYMPIC BLVD	90015	14	127-5A209 199	5139009015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.04266	-118.26051	"INSTALLING 2 NEW 400 AMP PANELS TAPPED FROM AN EXISTING 1600AMP PANEL WITHIN 25FEET FOR TWO NEW TENANTS IN THE BUILDING. NO NEW LOAD ADDED UNDER THIS PROJECT. FULL PLAN CHECK IS REQUIRED FOR ""PIZZA"" RESTUARANT. PERMIT # FOR KOREAN BBQ: 18041-10000-25600."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71371	13041-10001-27122	4239 E GLENMUIR AVE	90065	1	147A223   226	5465017002	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.09656	-118.21142	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71372	11041-20000-10159	6530 N LANKERSHIM BLVD # R,  S	91606	2	180B169   811	2335009022	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.03	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			Corrections Issued	05/18/2011 12:00:00 AM	ADDRESS	34.18952	-118.38758	"PLAN CHECK T24 ENERGY.  NEW LIGHTING FOR FIRE DAMAGE TO SUITES ""R"" & ""S"" TO (E) 1-STORY RETAIL COMMERCIAL BLDG."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71373	17041-10000-18065	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM			PC Info Complete	05/31/2017 12:00:00 AM	ADDRESS	33.94373	-118.40888	NEW 75'X34' TEMPORARY STEEL  CANOPY ABOVE BAGGAGE FACILITY (JUNE 30 - SEPT 22  2017)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71374	19041-20000-20594	11760 W SAN VICENTE BLVD	90049	11	129B145   107	4265018017	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.05288	-118.46798	PLAN CHECK FOR POWER AND ENERGY.CHANGE OF USE FROM RESTAURANT (A2-OCCUPANCY) TO MEDICAL OFFICE (B-OCCUPANCY).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71375	13041-10000-12014	657 W REDONDO BEACH BLVD 1-6	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			Reviewed by Supervisor	07/12/2013 12:00:00 AM	ADDRESS	33.89279	-118.28709	TI FOR POWER, TWO TENANATS INTO ONE SPACE, APPLICANT INDICATE TITLE 24 DONE UNDER SEPERATE PLAN CHECK. methane buffer zone.core/shell done under 13041-10000-03079	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71376	17041-10000-03094	20914 W NORDHOFF ST	91311	3	195B109     8	2779001037	C2-1, P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Info Complete	02/21/2017 12:00:00 AM	ADDRESS	34.23525	-118.58927	PC FOR ENERGY. TENANT IMPROVEMENT FOR A FITNESS GYM, NO CHANGE OF USE,  CONNECTED LOAD< 400A, TOTAL AREA 5140 SQ FT. B 17026-10000-00005	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71377	15041-10000-12350	700 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PC FOR POWER. LAX,TERMINAL 7  NEW CONVEYOR SYSTEM WITH 3 MAIN PANELS AND 3 CONTROL PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71378	10041-10000-16439	670 W 9TH ST	90731	15	015B197   801	7454005019	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			08/20/2010 12:00:00 AM	03/24/2011 12:00:00 AM		Permit Finaled	08/03/2012 12:00:00 AM	ADDRESS	33.73616	-118.29158	This is a 3 story with one level parking total 15k sqft. cummonity center. Lighting, power title 24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71379	13041-10000-07258	7112 N BECKFORD AVE	91335	3	183B121   272	2129003003	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1325.01	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.19962	-118.55116	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.88KW. USING 18 PANELS. TRANSFORMERLESS INVETER, NON STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71380	10041-20000-10061	6941 N COLDWATER CANYON AVE 1-17	91605	2	183B161   618	2327022005	R1-1, R3-1	South Valley	North Hollywood - Valley Village			1234.20	Electrical	Electrical	Apartment			05/27/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	05/16/2011 12:00:00 AM	ADDRESS	34.19669	-118.4141	fire alarm 19 units apartments and low voltage permit for for floors	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71381	15041-10000-16020	11100 W SANTA MONICA BLVD STE 450	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/26/2015 12:00:00 AM			PC Info Complete	05/26/2015 12:00:00 AM	ADDRESS	34.04726	-118.44465	Energy plan check for an office T.I, suit 450, located at the 4th floor of a high rise building; scope includes new light, receptacle and selective offices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71382	19041-10000-29729	9340 N ETON AVE	91311	12	198B105    71	2746010046	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.2406	-118.59517	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71383	11041-20000-01324	19900 W PLUMMER ST	91311	12	198B113    85	2761040010	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/21/2011 12:00:00 AM			PC Info Complete	01/21/2011 12:00:00 AM	ADDRESS	34.24259	-118.56723	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR PHILIPS GRAD. INSTITUTE. WORK ON ELECTRICAL WIRING ON EXISTING CKTS. NO NEW LOAD ADDED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71384	14041-20000-21007	10019 N HALBRENT AVE	91345	7	204B145   933	2660010024	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.25248	-118.46629	New roof mounted PV system with Enphase model number M250-60-2LL.  Total system size 3.51KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71385	12041-10000-21737	6345 N VARIEL AVE	91367	3	180B105    66	2149001032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	01/22/2013 12:00:00 AM		Permit Finaled	07/25/2013 12:00:00 AM	ADDRESS	34.18643	-118.5936	REPLACING AN EXISTING FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71386	17041-10000-33146	11938 W SAN VICENTE BLVD	90049	11	129B145   177	4265007037	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM			PC Info Complete	01/12/2018 12:00:00 AM	ADDRESS	34.05224	-118.47144	PC for T24 only for restuarant TI. Installing new lights, receptacles, two new panels, equipment. Total of 2377sqft. B#17016-10000-26948	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71387	18041-20002-32159	5147 S WEST BLVD	90043	8	108B185    96	5013003007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	33.99531	-118.33568	CHANGES TO PERMITED SET, CHANGES INCLUDE RELOCATING BATEERY, DC DISCONNECT AND INVERTER LOCATION. CHANGES APPLY ONLY TO DELTA B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71388	14041-20001-00503	4613 N WOLFE WAY	91364	3	168A109   149	2172013039	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.15383	-118.58903	((Expedite Fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71389	10041-10001-07501	3335 S FIGUEROA ST	90007		120A203   177	5123009027	(T)(Q)C2-2D-O		South Los Angeles	Empowerment Congress North Area			Electrical	Electrical	Commercial			11/16/2010 12:00:00 AM			PC Approved	11/16/2010 12:00:00 AM	ADDRESS	34.02224	-118.28008	Delta 6 changes; condensers are supplied from panel B ( 120/208V ) ; INCREASE IN LOADS SUPPLIED FROM PANEL DFirst tenant in commercial space-RETAIL/PHARMACY-CVS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71390	19041-20000-29748	6363 W WILSHIRE BLVD ste 115	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.06385	-118.3674	ti to an existing commercial building.  adding new lighting new controls to new panel. plan check for indoor energy only. high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71391	19041-20000-21963	1801 CENTURY PARK EAST ste 2050	90067										Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM				ti to an exisitng commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71392	13041-20000-34285	8700 W WENTWORTH ST	91040	7	207B189   154	2547002002	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2013 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.26706	-118.32394	New ground mounted PV system for an existing single family dwelling.  10.3kw AC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71393	19041-10003-19612	2500 W 7TH ST	90057	1	133-5A201 278	5141014001	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.0583	-118.28122	Change to an approved set by modifying the single line diagram. Scope includes adding 1 new panel (2A3) and relocating loads from 2A2 with one additional circuit. . Both panels to be connected to existing 50A meters.  All changes under delta-7 only. ((Full pc (pwr and energy) for commercial tenant spaces 2 story building. Existing service 800A, 120/240V, 1ph, 3w will existing and new loads. area of scope is 21,000sqft.))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71394	15041-10002-36182	764 N TERRACE 49	90042	1	153A223   397	5471015024	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM			PC Approved	01/12/2016 12:00:00 AM	ADDRESS	34.11165	-118.20945	01/12/16Changes to an approved set. Changes include switching from 12 Hyundai HiS-M250 MG solar modules to12 Solar World SW 250 poly solar modules. Note: Permit paid under PCIS#15041-10000-36182 ((((PV1, INSTALL 3.0 KW DCROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(12) MODULES: HYUNDAI SOLAR (1) INVERTER: ABB PVI-3.0-OUTD-US)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71395	09041-10001-24529	3303 W WILSHIRE BLVD # 102	90010	10	135B197  1231	5502027017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM			PC Approved	07/16/2010 12:00:00 AM	ADDRESS	34.06195	-118.29439	DELTA CHANGES TO  PLANS THAT WERE APPROVED FOR TITLE 24 COMPLIANCE-CHANGES ARE SHOWN CLOUDED ON THE PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71396	18041-20000-23738	14671 W COBALT ST	91342	7	228B149    35	2502021024	R1-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.32282	-118.45244	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71397	19041-10001-18025	6316 N TOPANGA CANYON BLVD 1120-1125	91367	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM			PC Approved	06/19/2019 12:00:00 AM	ADDRESS	34.18578	-118.60514	changes to an approved set of plans. changes include the relocation of receptacles and addition of mill work lighting. PERMIT FEES PAID UNDER 19041-10000-15355Energy plan check for an amusement enterprise located in the mall. Scope includes new lighting and equipment with a total area of 4940-SQ FTBld# 19016-10000-00916	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71398	18041-10000-45045	11100 W SANTA MONICA BLVD 5TH FL	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	12/17/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI OF CORRIDOR AND RESTROOMS ON THE 5TH FLR. T-24 ONLY. BUILDING PERMIT 18016-10000-35477	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71399	17041-10000-30519	9068 N DE GARMO AVE	91352	6	195B173    59	2408033009	M3-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.23385	-118.37328	T-24 ONLY. REPLACING EXISTING HID FIXTURES WITH NEW LED LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71400	13041-10000-26318	6330 N VARIEL AVE	91367	3	180B105    69	2149003009	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.18601	-118.59256	new multi-purpose office roomplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71401	16041-10000-04186	1515 N VERMONT AVE 8TH FL	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.09867	-118.29207	Pc for energy. Tenant improvement to convert 2 exam rooms space  to 3 exam rooms in an existing 8th floor medical office building. Total area  255 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71402	14041-10000-16397	8550 N BALBOA BLVD 220	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.22649	-118.5024	PLANCHECK FOR POWER AND ENERGY. Tenant Improvement to existing office space. 8038 SQFT, EMERGENCY LIGHTING. PERMIT PREVIOUSLY PULLED UNDER 14041-90000-15327.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71403	15041-20000-26074	23228 W CASS AVE	91364	3	165B097    74	2076015036	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.15182	-118.62056	PV1. Install roof mounted PV system sized 6.0 kW. Interconnected with main service panel. (27) Toina Solar tsm-255 Modules(1) ABB PVI-6000 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71404	19041-10000-13389	1248 S FIGUEROA ST	90015	14	126A205    19	5138025014	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Closed	11/06/2023 12:00:00 AM	ADDRESS	34.04096	-118.2674	PC FOR TEMP POWER SCOPE INCLUDES NEW SERVICE 2000A 3PH 480V ADDITIONAL EQUIPMENT AND PANELS. DEMO B# 19019-10000-02387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71405	16041-20001-02261	7277 N GLENHAVEN CT	91307	12	186B089   579	2027049025	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	01/31/2016 12:00:00 AM	ADDRESS	34.20386	-118.64865	Expedited per customer request.PV1. Intalling roof mounted PV system sized 9.6 kW. Interconnected with main service panel.(38) Kyocera KU265 Modules(1) ABB PVI-6000 Inverter(1) ABB PVI-3.6 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71406	10041-20000-25619	8300 N VAN NUYS BLVD	91402	6	192B149   361	2638022044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.22189	-118.44858	PLAM CHECK POWER AND ENERGY FOR RETAIL TI (VERIZON WIRELESS STORE)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71407	19041-10000-48246	3308 S CORINTH AVE	90066	11	120B157   989	4250024015	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.021	-118.4285	NEW ROOF MOUNTED 8.6KW PV SYSTEM WITH 27 PV PANELS @ 320W AND OPTIMIZER AND ONE CENTERAL INVERTER @ 6KW ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71408	18041-30000-01541	10007 S CENTRAL AVE	90002	8	090B209   216	6049028026	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2407.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	33.94544	-118.25433	Plan check for Title 24 only in existing space. Total area: 1,867 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71409	17041-20000-42117	7242 N VALJEAN AVE	91406	6	186B137   367	2205027029	MR1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.2024	-118.48575	PV2.  Install 50.66 kW DC roof mounted grid tied PV system.  (149) modules with (2) 24kW string inverters.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71410	16041-20000-45768	3980 W WILSHIRE BLVD	90010	10	132B189    79	5092030035	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	12/03/2020 12:00:00 AM	ADDRESS	34.06153	-118.31391	Plan check for power and energy. New 7-story mixed-use building with approximately 15,346 sq. ft. ground retail and 228 residential units above. Ground level and 3 subterranean levels of parking. 5000A service. Fire alarm variance is on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71411	15041-10000-25756	9715 N MARCUS LANE	91042	7	201A201   387	2564016040	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/21/2015 12:00:00 AM	ADDRESS	34.24486	-118.28253	PV 1 ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY HOME. 4.2KW INTERCONNECTED WITH THE MAIN SERVICE PANEL. (17) MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71412	17041-10000-45620	741 S SOTO ST	90023	14	124-5A221 254	5183027041	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.03475	-118.21569	PC for new methane mitigation system. Installing 11 new devices, two new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71413	18041-10000-07061	16521 W SATICOY ST	91406	6	186B137    22	2205009009	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.20858	-118.49305	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL  AFFECTED AREA IS 8575 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71414	14041-10001-24542	4620 N TILDEN AVE	91423	4	168A151   109	2265013023	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			PC Approved	03/18/2015 12:00:00 AM	ADDRESS	34.15558	-118.44746	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{INSTALL 16830 W DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(66)MODULES: SUNIVA OPT 265-60-4-100(2) INVERTER(S): SMA AMERICA SB7000US}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71415	16041-20000-27376	21550 W OXNARD ST Suite 710-720	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	10/06/2016 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,208 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71416	14041-20000-21437	19651 W LANARK ST	91335	3	189B117    27	2105002014	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Expired	09/08/2016 12:00:00 AM	ADDRESS	34.21805	-118.56183	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WITH MSP.(29) TRINA SOLAR TSM255 MODULES(29) SOLAR EDGE OPTIMIZERS P300(1) SOLAR EDGE SE6000 TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71417	15041-20001-08515	20122 W VANOWEN ST	91306	3	180B113    25	2134014024	(T)(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1348.00	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.19364	-118.57195	Changes to approved set.  New lighting fixtures used + updates to Title-24.*****Previous Work Description*****Plan check for Title 24 only. Project scope is a tenant improvement to an existing commercial space. Total lighting area = 620 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71418	14041-20001-02476	6080 W CENTER DR 3RD FLOOR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	05/30/2014 12:00:00 AM	ADDRESS	33.97713	-118.39172	Modifications to approved set.  Change of layout and scope of work to include additonal areas/remove others.  (((T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON THE 3RD FLOOR)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71419	16041-20000-06267	10010 N CASABA AVE	91311	12	204B113   665	2741018022	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.25222	-118.57594	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (24) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71420	17041-10000-37882	6859 N TOPANGA CANYON BLVD	91303	3	183B101   647	2024005023	(WC)TOPANGA-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1351.11	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.1954	-118.60614	TITLE 24 ONLY, RELACE INDOOR HID FIXURES WITH NEW LED FIXURES, TOTAL SQUARE FOOTAGE 38425 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71421	14041-10000-06629	5028 E ALHAMBRA AVE	90032	14	136-5A233  38	5216024006	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			03/12/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.06991	-118.17642	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 5942 SQFT. ALL WORK TO BE INDOORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71422	14041-10000-22143	4354 N TEESDALE AVE	91604	2	165B161   333	2375003010	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			08/15/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.14998	-118.40825	Plan check for lighting and power.  Construction of new 16 unit apartment building.  New 1200 A service, 30 HP elevator, 16 house panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71423	09041-10002-20183	701 S HILL ST 1ST & 2ND-FLOORS	90014	14	129A209   229	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM			PC Approved	09/22/2010 12:00:00 AM	ADDRESS	34.04582	-118.25475	rEVISIONS TO PERMITTED SET OF PLANS  P/C is for Power and Energy. RENOVATIONS OF JEWELRY SHOPS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71424	19041-10000-30278	13755 W ROSCOE BLVD	91402	6	192B153   739	2637029012	P-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	01/10/2022 12:00:00 AM		Permit Closed	05/31/2024 12:00:00 AM	ADDRESS	34.22182	-118.43315	******FEE ESTIMATE***************FULL PLAN CHECK FOR POWER AND ENERGY, SCOPE OF WORK IS A FIRST TIME TENANT (NEW STARBUCKS), TOTAL CONNECTED LOAD IS OVER 400A. SCOPE OF WORK INCLUDES NEW CIRCUITS AND LIGHITNG AND CONTROLS AND TWO NEW PANELS. TOTAL AFFECTED AREA IS 1669 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71425	11041-20000-12529	8500 W BEVERLY BLVD 8th Floor	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/16/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	T.I. to existing high rise building.  Install general/emergency lighting in the corridor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71426	19041-10002-32187	4935 N CALVIN AVE	91356	3	168B117    75	2175010019	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	34.15997	-118.56038	Suppl App to replace the lost plans. Plan Check Only. Permit #: 19041-10000-32187<<<Plan check for a 10 kw AC / 10.68 KW DC PV1, roofmounted system. Scope includes (1) inverter, (35) modules and optimizers interconnecting through the main service panel.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71427	17041-20000-32975	18913 W SHERMAN WAY	91335	3	183B121    83	2104034014	[Q]C1-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.20129	-118.54532	Plan check for a PV2 roof-mounted PV system. System size is 14.7 kWac and consists of (64) modules, (64) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71428	16041-10000-02059	20610 W CHATSWORTH ST	91311	12	207B109   362	2707009006	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	34.26426	-118.58249	PV1, Install 3.975 kW DC roof-mounted solar array, interconnect with an existing 3.0 pv system through a 125Amp load center.  (1) INVERTER:  ABB PVI-3.6-OUTD-S-US-Z-A.  (15) Modules: KYOCERA  KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71429	10041-10000-16569	1225 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	02/14/2011 12:00:00 AM	ADDRESS	34.05186	-118.22629	Solar voltaic system installed on the roof of the building.  Consists of 6 modules, 6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71430	13041-10000-05508	110 N GEORGE BURNS ROAD	90048	5	138B169   247	4334006023	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/04/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.07564	-118.38149	In the Schuman Building, renovate and convert existing basement  space to equipment storage room with freezers. Aan emergency feeder and an normal feeder from an existing EMswitchboard board in the Davis Building  are used to supply the equipment in the basement of  the schuman building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71431	15041-20000-36785	14556 W VENTURA BLVD	91403	4	166-5A151 127	2276001012	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM	11/02/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.15107	-118.45065	Plan check  Title 24 only  for existing space in the rest room Sequestial Brand Group. Total area: 61 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71432	19041-10000-34949	19812 W KITTRIDGE ST	91306	3	180B113   382	2134007014	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.19095	-118.56483	Plan check for a PV1 7.6k Dc / 6.5KW AC roof mounted system . Scope includes (27) modules,(1) load center,  and (2) string of Enphase microinverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71433	16041-10000-42919	261 S FIGUEROA ST #120B	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			12/07/2016 12:00:00 AM			PC Approved	12/07/2016 12:00:00 AM	ADDRESS	34.05546	-118.25446	Plan check for Title 24 only in exising space T.I. Total area: 2645 sq ft.Note: permit paid under separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71434	17041-10000-10721	150 W 12TH ST	90015	14	126A207   234	5139025028	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.03831	-118.26077	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 94,400. total # of units = 15.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71435	15041-10000-32875	18653 W HORACE ST	91326	12	210B121   564	2717013031	RE11-1	North Valley	Northridge	Northridge West		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.2697	-118.53937	PV1 roof mounted solar panel, 11.8 kW system(40) modules: Sunpower SPR-327-NE-WHT-D(2) PVI-3.8-OUTD-S-US(1) PVI-4.2-OUTD-S-USPanel Upgrade 225A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71436	14041-10000-36039	801 S HOPE ST Unit C	90017	14	129A209   268			Central				2077.10	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	09/03/2015 12:00:00 AM	ADDRESS	34.04656	-118.25938	First Tenant-sandwich shop - in commercial bldgfull plan chk	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71437	12041-20000-09775	1730 W CORDOVA ST	90007	1	126B197   893	5075037008	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM			PC Approved	06/13/2012 12:00:00 AM	ADDRESS	34.03889	-118.29553	9326 total sqft. (5088 unconditioned, 4238 conditioned sqft) Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71438	13041-10000-20691	1317 E WASHINGTON BLVD	90021	14	120A211    57	5129002036	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	10/21/2014 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.02434	-118.24988	PLAN CHECK POWER AND ENERGY FOR NEW GAS STATION BUILDING AT EXISTING GAS STATION SITE.  EXISTING CAR WASH & CANOPY TO REMAIN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71439	13041-70000-18137	8049 N NESTLE AVE	91335	12	189B125   180	2102007012	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	09/27/2013 12:00:00 AM	ADDRESS	34.21711	-118.53099	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.5 KW. USING 31 MODULES. TRANSFORMERLESS INVERTER. 2 STRINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71440	14041-10001-35081	9020 N RESEDA BLVD SUITE 102	91324	12	195B125    51	2769001031	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM			PC Approved	01/29/2015 12:00:00 AM	ADDRESS	34.2346	-118.53587	Supplamental application for Title 24 only. Changes to an approved set of plans. Changes were made to the single line diagram so that the single line diagram would match what is on the field. Equipment is existing. No change of use; no need for power plan check. Permit is existing under master application.(((Energy plan check for a restaurant T.I.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71441	19041-10000-50685	9021 N MONOGRAM AVE	91343	12	195B137    90	2688001023	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.23451	-118.49285	[EPLAN] NEW PV1 ROOF MOUNTED INSTALLATION WITH SYSTEM SIZE OF 8KW DC/ 7.875KW AC, WITH 25 SUNPOWER MODULES (320W), 25 MICROINVERTERS (ENPHASE IQ7X), 1 ESS (TESLA POWERWALL), 1 COMBINER BOX, 1 SUBPANEL CONNECTED TO AN EXISTING MAIN SERVICE PANEL RATED AT 200A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71442	11041-10000-25184	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM	12/23/2011 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	PIN	33.94363002	-118.42513364	T.I.  Federal Express Hangar.  1 out of 3 applications.  This application deals with the new 2-story modular unit that is to be permanently installed within the Federal Express hangar.  The modular unit is not state approved.   This plan shows the 2 panels pertaining to the modular unit, but these panels have already been charged on the power application (11041-10000-15257).  This plan also shows the lighting and power for the modular unit.  This application also deals with charging the new branch circuits and non-dwelling power equipment reflected on this plan set.  Title-24 calculations within the hangar and the new 2-story modular unit that is to be permanently installed is under 11041-10001-15257.  The power portion (single line diagram) of the project along with showing the lighting side of the office space that is to be remodeled is under 11041-10000-15257.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71443	19041-20001-29056	690 S ALAMEDA ST	90021	14	124-5A215  52	5164023025	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	34.03528	-118.2384	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. UPDATE TO TITLE 24 LIGHT QUANTITY AND CHANGE TO LIGHTING FLOOR PLAN WITH ADDITION OF PARTITIONS AND ONE MORE LIGHT AND REARRANGING OF LIGHTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71444	14041-20000-06505	12746 W JEFFERSON BLVD # 3100	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	10/27/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR POWER ONLY. EXTENDING A SERVICE FOR FUTURE CVS. VERIFY PROJECTED LOAD AND FAULY CALC AT CVS POINT. (RESROOM ELECTRIC BY OTHERS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71445	19041-30000-46345	5700 N CANOGA AVE 1ST FLR	91367	3	174B105    83	2149019015	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.17365	-118.59715	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING, CONTROLS, AND CIRCUITS. TOTAL AFFECTED AREA IS 1816 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71446	14041-20000-12421	2101 E 7TH ST	90021	14	124-5A217 220	5164018008	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			05/09/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.03472	-118.22999	Add heat pump to 38 units and change meter bank from 400 to 600 Amp bussing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71447	13041-10003-31282	22100 W INDEPENDENCIA ST	91364	3	168B101  1005	2076022060	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM			PC Approved	01/02/2014 12:00:00 AM	ADDRESS	34.15268	-118.60797	][] $0 FEE DUE TO  2012 SENATE BILL 1222. CHANGES MADE TO AN APPROVED SET OF PLANS; PER INSPECTOR REQUEST NEW PLANS WERE SUBMITTED TO REFLECT ACTUAL WORK (TO INCLUDE PERFORMANCE METER IN SINGLE LINE DIAGRAM). (1) ADDITIONAL PLAN CHECK HOUR CHARGED. WORK IN CONJUNCTION TO PC#13041-10000-31282 ][][PV1, ROOF-MOUNTED 5.4KW DC PHOTOVOLTAIC SYSTEM INSTALLATION WITH TRANSFORMERLESS, WITH (20) MODULES (SOLARWORD SW270) AND  POWER-ONE PVI-5000-OUTD-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71448	18041-20000-45421	3951 N CODY ROAD	91403	4	163-5A147 150	2277014007	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	12/23/2018 12:00:00 AM	ADDRESS	34.14223	-118.46449	PV1.  Install 12.81 kW roof mounted grid tied PV system.  (42) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71449	16041-10000-20811	535 W 91ST ST	90044	8	094-5A201  57	6038007041	RD5-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	33.95429	-118.28378	PV1. NEW SOLAR ARRAY ON EXISTING RESIDENTIAL ROOF-TOP. THIS IS AN ADDITION TO EXISTING PV SYSTEM. SCOPE INCLUDES ADDING A NEW 7.6KWac INVERTER WITH A  NEW 125A SUBPANEL. RECONNECT EXISTING PV SYSTEM TO LOAD CENTER. TOTAL SYSTEM SIZE WITH NEW AND EXISTING IS 11.6KWac.(31)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-FRONIUS#PRIMO 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71450	18041-10000-26874	1150 S OLIVE ST 17TH FLOOR	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	11/20/2018 12:00:00 AM	ADDRESS	34.03962	-118.26181	PLAN CHECK FOR T24 ONLY, TI ON 17TH FLOOR , PROVIDE NEW LIGHTINGS AND POWER. NEW CIRCUITS ARE FED FROM EXISTING PANELS. TOTAL AREA: 15,758 SQ.FT((B# 18016-10000-22055))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71451	13041-10000-21234	111 S KINGS ROAD	90048	5	138B173   660	5511015010	R3-1	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			08/08/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	08/20/2014 12:00:00 AM	ADDRESS	34.07409	-118.37238	NEW 20 UNIT , 3-STORY APARTMENT. PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71452	14041-10000-10393	9520 W MONTE MAR DR	90035	5	129B165   610	4306023004	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.04921	-118.39606	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71453	17041-20000-01324	3715 S MCCLINTOCK AVE b23	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.02041	-118.29027	ti to an existing commecial space (RESEARCH LABORATORY AND SUPPORT SPACE).  plan check for energy only.  total square footage 1377	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71454	12041-10000-13578	11350 W SHELDON ST	91352	7	201B173   117	2538023006	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2012 12:00:00 AM			Verifications in Progress	07/03/2012 12:00:00 AM	ADDRESS	34.25051	-118.37823	INSTALLATION OF A GROUND-MOUNTED 12.9KW PHOTOVOLTAIC SYSTEM FOR A SFD RESIDENCE. PV SYSTEM WILL  BE NEAR THE DETACHED GARAGE. SYSTEM CONSISTS OF 43 SOLAR MODULES, INVERTERS COMBINER BOXES AND WIRING. MAIN LOAD CENTER FOR THE SFD IS UPGRADED TO 225A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71455	14041-20000-03985	14221 W VENTURA BLVD	91423	4	165B153   341	2265019009	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/12/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.15015	-118.44293	INTERIOR TENANT REMODEL OF AN EXISTING RETAIL SPACE. TO BE A PART OF AN EXISTING GUITAR CENTER NEXT BUILDING. NEW LIGHTING AND NEW ELECTRICAL FOR NEW RETAIL SPACE. NEW LOAD LESS THAN 400A. PER APPLICANT, SEPERATION BY FIRE RATED WALLS. INSPECTOR TO FIELD VERIFY THE USE OF 2 SERVICES OR TO CONSOLIDATE TO ONE.  PLAN CHECK IS FOR TITLE 24 ONLY FOR CHANGES TO LIGHTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71456	16041-10000-17646	7647 N ETON AVE	91304	3	186B105    68	2109031004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			05/19/2016 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.20959	-118.59573	PV1. ADDING NEW SOLAR TO AN EXISTING SOLAR PV SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. SCOPE INCLUDES ADDING 5.0KWac TO AN EXISTING 6KWac SYSTEM.  TOTAL SYSTEM SIZE WITH EXISTING AND NEW IS 11.0KWac. NEW EQUIPMENT INCLUDES:(20)MODULES-HYUNDAI HIS-S280RG(1)INVERTER-FRONIUS PRIMO 5.0-1(1)125A SUBPANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71457	18041-10000-35540	11601 W WILSHIRE BLVD Ste.# 103	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	INTERIOR TENANT IMPROVEMENT OF AN EXISTING OFFICE SPACE IN 1ST FLOOR. TOTAL AREA: 3,594 SQ.FT(B# 18016-10000-26716)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71458	15041-10000-15981	2712 S HALLDALE AVE	90018	8	123B193   947	5053029003	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.03041	-118.30261	PV1, INSTALL 6.867 KW DC ROOF-MOUNTED SOLAR ARRAY ON A RESIDENTIAL HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(22) MODULES: SUNPOWER SPR 327ne-wht-d(1) INVERTER: ABB PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71459	17041-10001-31456	10459 W TUXFORD ST #B	91352	7	198B177   137	2544014016	A1-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM			PC Approved	09/14/2017 12:00:00 AM	ADDRESS	34.23764	-118.35908	OFF HOUR PLAN CHECK PERMIT 17041-10000-31456PLAN CHECK FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL PROPERTY. SYSTEM SIZE 6KVA INVERTER(SUNNYBOY SNA 6.0-US) WITH 17 MODULES(LG 395N2W-A5)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71460	10041-20002-16395	8732 S READING AVE #1-11	90045	11	096B169   627	4125016012	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM			PC Approved	02/27/2014 12:00:00 AM	ADDRESS	33.95901	-118.3814	((2/27/2014: CHANGES MADE TO APPROVED SET OF PLANS. SWITCHBOARD CONFIGURATION CHANGES. LOADS HAVE NOT CHANGED. SERVICE SIZE HAS NOT CHANGED. ADDITIONAL PERMIT IS NOT REQUIRED)))Plan check for revision to approved plans. Revision to include new water heater branch ckts, BBQ plug, unit layout (additional bathroom), T24 Energy calculation, and 30HP elevator..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71461	16041-10000-41565	2111 S LONG BEACH AVE WEST	90058	9	118-5A213 361	5118025003	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.01755	-118.24352	Plan check for Title 24 only in existing space building weare house, portion of building to retail . Total area: 1773 sq ftB#16016-10000-21224	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71462	12041-10000-04270	6220 W 3RD ST	90036	4	135B177   585	5509003018	[Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM			PC Approved	02/27/2012 12:00:00 AM	ADDRESS	34.07057	-118.3565	T.I. to roof terrace on an existing apartment complex (above the recreation facility).  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71463	14041-10000-06083	11035 N SUTTER AVE	91331	7	210B157   500	2535001013	M2-1-O	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	03/06/2014 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.27032	-118.42538	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES.  12798 SQFT. ALL WORK TO BE INDOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71464	10041-10000-22442	12780 N CHALON ROAD	90049	11	141B137    49	4493005011	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2010 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	ADDRESS	34.08327	-118.49819	New Natural Gas Fuel Cell (ClearEdge) for single family dwelling. Plan check for power. (LAFD approval not required per LAFD.)  A variance to install a non approved equipment, Fuel Cell was submitted on April 12, 2011.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71465	18041-10000-03391	10632 N ORO VISTA AVE	91040	7	207B189   848	2555023078	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.26227	-118.31561	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71466	11041-20000-08648	1691 W ADAMS BLVD	90007	1	123B197   818	5054004031	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.00	Electrical	Electrical	Commercial			04/28/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Closed	07/24/2012 12:00:00 AM	ADDRESS	34.03288	-118.29995	T.I. to existing building.  Install general/emergency lighting for indoor and outdoor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71467	19041-10000-43024	1273 W 36TH PL	90007	8	120B197  1019	5040007017	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			10/22/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	02/05/2024 12:00:00 AM	ADDRESS	34.022	-118.29677	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS ONE NEW FIRE ALARM PANEL, AND 14 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71468	14041-10000-05490	21933 W VENTURA BLVD SUITE A	91367	3	174B101   389	2168027034	[T][Q]C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	PIN	34.16940578	-118.60503747	"engineer or contractor or designer missing. PC FOR ENERGY ONLY. PERMIT TO BE PULLED AT epc counter. less than 400 A per applicant. 14016-10000-03359 building description: CHANGE OF USE FROM RETAIL TO BARBER SHOP.  INTERIOR REMODEL ONLY.  CHANE OF USE PORTION OF THE BUILDING FROM (19'-9""X58'-1"") RETAIL TO BARBER SHOP 1 STORY BUILDING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71469	14041-10000-22712	909 S SANTA FE AVE	90021	14	123A217   108	5166012010	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM	09/18/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.03228	-118.23021	PLANCHECK FOR POWER. TENANT IMPROVEMENT. UPGRADE OF SERVICE TO 600AMPS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71470	17041-20002-00400	7353 N HILLSVIEW CT	91307	12	186B089   413	2027047015	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2017 12:00:00 AM			PC Approved	01/23/2017 12:00:00 AM	ADDRESS	34.20547	-118.65133	(1/23/2017)changes to an approved set of plans.  relocate subpanel in garage and reroute conduit to msp.this is plan check only.  PV, INSTALLATION OF 11 KW AC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY HOUSE.(32) AC MODULES: SUNPOWER SPR-X21-345-C-AC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71471	17041-20001-35925	7223 N TYRONE AVE	91405	2	183B153   105	2217003040	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Apartment			03/08/2019 12:00:00 AM			PC Approved	03/08/2019 12:00:00 AM	ADDRESS	34.20174	-118.44468	03-08-2019 Changes to an approved set of plans, Changes include revised overcurrent protection from fuse to series rating circuit breaker. all changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71472	13041-20000-21604	15260 W VENTURA BLVD STE 1705	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM	08/12/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.15356	-118.4658	Plan check for energy and emergency lighting. Commercial high-rise. Suite 1705 17th Floor. Douglas Emmett, Gorelick and Uslander.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71473	13041-10000-03296	1936 E 1ST ST	90033	14	129A221   303	5174016031	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			02/08/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.04587	-118.21637	New fire alarm system. 1 fire alarm panel with 91 devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71474	17041-20000-11931	726 N HUDSON AVE	90038	4	141B185   443	5533035021	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			04/12/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.08412	-118.33193	Plan check for power and energy. Project site is a new 4-story, 17-unit apartment building over 1 story of subterranean parking garage. Total lighting area = 8,758 sq. ft.Note: Building permit has been pulled under 16010-20000-05171	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71475	10041-10003-23139	1166 S SOTO ST	90023	14	121-5A221  24	5170005026	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2047.00	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM			PC Approved	02/03/2011 12:00:00 AM	ADDRESS	34.02828	-118.2191	Change the priviously approved plan.  Delta 5.  Install 2 @ lights in the mechanical room, change 60 Amp CB for the Vacuum to 70 Amp with #4.                 (((((((((((((((((UPGRADE AN EXISTING CAR WASH IN AN EXISTING GAS STATION. INSTALL A NEW 600 AMP SERVICE.))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71476	18041-20000-35115	11380 W DONA TERESA DR	91604	2	159B169   651	2381010007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Permit Finaled	12/04/2018 12:00:00 AM	ADDRESS	34.12938	-118.38142	Plan check for PV roof mounted and energy storage system. System size: 7.6kW with 23 modules and 1 inverter(7.6kW ) and 1 battery 9.8kWh LG Battery	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71477	14041-20003-00123	1457 W COLORADO BLVD	90041	14	162A227   402		[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	34.13954	-118.1965	Modification to approved set.  Change of feeder sizes.  $0 plan check fee is due to State Senate Bill SB-1222.  Note: Permit is under the original application.*****Previous Description*****(((PV2 COMMERCIAL ROOF TOP SOLAR. TOTAL SYSTEM SIZE 56 MICROINVERTERS USING THE ENPHASE 250. TO BE VERIFIED WITH TEST LAB APPROVAL. TOTAL SIZE 13.4KW AC. TOTAL OF 2 SYSTEM INTERCONNECTIONS. TOTAL SERVICE SIZE IS 1200A. PLAN CHECK TO EXTEND TO ENTIRE SERVICE. use of transformer to make compatable 3phase connection)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71478	11041-10000-17100	1221 S GAFFEY ST	90731	15	015B197  1449	7454022003	(Q)P-1XL	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	ADDRESS	33.73294	-118.2925	TI TO AN EXISTING PHARMACY.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71479	18041-20000-22147	10250 W CONSTELLATION BLVD Corridor-8th Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 Energy only in existing space corridor 8th floor lighting. Total area; 262 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71480	19041-10000-19473	5005 S MCCONNELL AVE 1ST FLOOR	90066	11	105B157   602	4221031003	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	04/09/2021 12:00:00 AM	ADDRESS	33.98207	-118.4231	TENANT IMPROVEMENT IN OFFICES AND  NEW EXTERIOR LIGHTINGPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71481	11041-10000-12952	400 W WASHINGTON BLVD	90007	9	123A205     2	5126014904	C2-2-O, M1-2-O, R4-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	06/27/2011 12:00:00 AM	PIN	34.03156505	-118.27070471	TEMPORARY 800A SERVICE AND ASSOCIATED EQUIPMENT  FOR THE CONSTRUCTION OF NEW PARKING STRUCTURE AT LA TRADE TECH;	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71482	17041-20000-03837	8147 N MASON AVE	91306	3	189B109    29	2108002023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.21817	-118.57994	Plan check for a PV1 roof-mounted PV system. System size is 6.6 kWac and consists of (1) inverter and (26) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71483	17041-20000-18154	7606 N FALLBROOK AVE #8	91304	12	186B097   194	2013008054	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Issued	11/16/2017 12:00:00 AM	ADDRESS	34.20847	-118.6232	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.Building application # 17041-10000-10540	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71484	14041-10001-31233	909 S SANTA FE AVE	90021	14	123A217   108	5166012010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.03228	-118.23021	changes to permitted set of plans: ADDING NEW CIRCUITS  TO EXISTING PANELBOARDS; FEEDER  AND CIRCUIT BREAKER TO MAIN PANEL 909A INCREASED TO CARRY THE NEW LODS ADDED TO THE SUBPANELS; FEEDER LOAD CALCULATION REDONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71485	12041-20000-07266	15260 W VENTURA BLVD	91403	5	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/29/2012 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.15356	-118.4658	Existing high rise office elevator lobby and bathroom remodel. Plan check for energy and emergency lighting. 19th floor. 421 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71486	16041-10001-18564	3812 W OAKWOOD AVE	90004	13	138B197    84	5501001023	M1-1	Central	Wilshire	Rampart Village		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM			Reviewed by Supervisor	06/08/2016 12:00:00 AM	ADDRESS	34.07761	-118.28979	EXPEDITED RSESPLAN CHECK PER APPLICANT REQUEST.<<<PV1, NSTALL NEW 11.28 KW DC ROOF-MOUNTED SOALR ARRAY ON A SINGLE FAMILY HOUSE.(41) MODULES:SOLARWORLD SW 275 MONO BLK(41)MICROINVERTERS: ENPHASE ENERGY M250-60-2LL-S25>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71487	17041-20000-00102	21250 W CALIFA ST	91367	3	174B105    16	2149002018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM			PC Info Complete	01/24/2017 12:00:00 AM	ADDRESS	34.1769	-118.59414	Plan check for power and energy. Remodel interior to add catering kitchen and convert 2320 SF of Warehouse Area to assembly room. Place of Assembly per Article 518. New lighting (incl. emergency). 3,279sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71488	14041-20000-34664	6530 W COMMODORE SLOAT DR	90048	5	132B173    37	5088009009	R2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.06207	-118.37115	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP (w/200A main breaker). Note: Main service is located on a detached garage, running conduit underground through trench.System size: 10kW. Ungrounded system.36  270W pv modules across 3 strings (12+12+12).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71489	19041-20000-51803	3501 W SUNSET BLVD	90026	13	144A203   188	5429024001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM			Reviewed by Supervisor	01/23/2020 12:00:00 AM	ADDRESS	34.08906	-118.27633	"PLAN CHECK FOR POWER AND ENERGY FIRST TIME TENANT ADD NEW PANEL, LIGHTS AND EQUIPMENTS.NOTE PER BUILDING:""TENANT IMPROVEMENT FOR A NEW TAKE-OUT JUICERY"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71490	15041-10000-31717	266 S HARVARD BLVD STE 200 &-205	90004	10	135B193   181	5517019030	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM	ADDRESS	34.06926	-118.30396	FULL PC FOR POWER AND ENERGY. TI ON EXISTING 4-STORY COMMERCIAL BUILDING (AMBULATORY SURGERY CENTER, NOT AN OSHPD 3, UNDER DOCTOR'S LICENSE). SCOPE INCLUDES 4 NEW PANELS, 1 800A MAIN SWITCHBOARD, AND NEW LIGHTING. TOTAL AREA IS 5209 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71491	16041-20000-34883	5161 N LEGACY CT	91364	3	171B097   724	2075012048	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	11/10/2016 12:00:00 AM	ADDRESS	34.16385	-118.62109	Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (1) inverter, (23) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71492	17041-10003-37680	5455 W 111TH ST	90045	11	087B173    10	4129036910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	33.93635	-118.37364	Change to approved set by updating equipment and adding circuits. all changes under delta-1 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71493	19041-20000-13425	17100 W LABRADOR ST	91325	12	201B133   154	2692012020	A2-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2019 12:00:00 AM	04/22/2019 12:00:00 AM		Issued	04/22/2019 12:00:00 AM	ADDRESS	34.24973	-118.50513	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (1) battery back-up unit and (1) load center to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71494	15041-10000-01900	5933 W CENTURY BLVD	90045	11	090B169    16	4124030016	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/22/2015 12:00:00 AM			PC Approved	01/22/2015 12:00:00 AM	ADDRESS	33.94571	-118.38747	Title 24 plan check only.  Total area = 120 sq. ft.T.I. to storage space in existing hotel building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71495	18041-20000-25009	19010 W KESWICK ST	91335	3	186B121    45	2104013009	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Issued	07/05/2018 12:00:00 AM	ADDRESS	34.21003	-118.54741	Plan check for PV roof mounted system, system size: 10.79kW AC CEC with 47 modules and 2 inverters(5.2kW and 7.6kW) connected to MSP 400A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71496	19041-10000-14853	2700 S MAPLE AVE	90011	9	120A207   276	5128009025	[Q]RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	03/03/2020 12:00:00 AM	ADDRESS	34.02234	-118.26597	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71497	13041-10001-29379	1109 S GLENDON AVE	90024	5	132B153   180	4363022003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/02/2014 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.06052	-118.44439	Supplemental to approved set- changes to architecture layout. Plan check for power and energy.  ((T.I. for new restaurant in an (E) 2-story building.  No change of use.  Proposed occupant load in excess of 200 occupants, likely A2 occupancy.  Power and energy.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71498	19041-10000-31802	11010 W PICO BLVD	90064	5	126B153  1103	4256007001	C2-1VL-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	09/12/2019 12:00:00 AM	ADDRESS	34.03798	-118.43258	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71499	14041-10000-22145	3530 W WILSHIRE BLVD #1110	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.06154	-118.30122	permit to be pulled at EPC counter only. Plan check for energy only per 2008 standards). <400A connected load. Suite #1110 -  BLDG#14016-10-10787. INTERIOR TENANT IMPROVEMENT. NON BEARING WALLS TO CREATE OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71500	19041-10000-53852	7240 N FULTON AVE	91605	2	186B157   604	2327002037	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	05/05/2020 12:00:00 AM		Permit Finaled	03/07/2022 12:00:00 AM	ADDRESS	34.20231	-118.42238	FULL PLAN CHECK FOR POWER AND LIGHTHING FOR A TI. 800A SERVICE, 120/240V. SCOPE OF WORK INCLUDES A NEW 800A MAIN SERVICE PANEL, SUBPANELS AND A MOTOR. TOTAL AFFECTED AREA IS 2840 SQUARE FEET.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71501	15041-20000-40812	10857 N BLUCHER AVE	91344	12	207B141    64	2662022018	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.26795	-118.47316	PV1, roof mounted solar 3.8kW AC interconnected (Upgrade) to 200A Service.(12) SPR-327NE-WHT-D(1) ABB PVI-3.8-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71502	19041-20001-32295	8414 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Approved	10/11/2019 12:00:00 AM				10-11-2019 Changes to an approved set of plan, Changes include relocate PV disconnect. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71503	14041-20001-34432	350 S GRAND AVE SUITE 1670	90013	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	PIN	34.05160512	-118.25169569	***Changes to an apporved set: Added lighting fixturesTI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS, ADDING NEW CIRCUITS.  WORK TO BE PERFORMED IN SUITE 1670.  TOTAL SQUARE FOOTAGE 3425.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71504	19041-10000-53563	6101 W 96TH ST ITF-West F/A	90045	11	093B169   346	4124020***	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	06/12/2020 12:00:00 AM		Permit Finaled	06/07/2022 12:00:00 AM	ADDRESS	33.94901	-118.39043	NEW FIRE ALARM SYSTEM TO A PARKING GARAGE. (1) FA PANEL , (38) POWER SUPPLIES AND (735) FA DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71505	19041-30000-50018	20326 W VIA MANTUA	91326	12	219B113   240	2701059032	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.29838	-118.57649	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 10KWac, SCOPE OF WORK IS 36 MODULES (HANWHA Q-CELLS SC315) WITH OPTIMZERS (SE P400), AND A CENTRAL INVERTER (SE10000H-US). NO MPU	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71506	11041-10005-23439	20600 W VENTURA BLVD North-1-123	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			02/03/2015 12:00:00 AM			PC Info Complete	02/03/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	Delta 3 changes to permoitted set of plan;, new panelboards,new ckts; new panel breakers; branch circuit rating for water heater in retail rest roomsALL CHANGES ARE MARKED WITH DELTA 3 AND CLOUDED.North Building of a New 123 unit Apartment building with Commercial space.  1200A service for Commercial space and 2000A service for apartment space.  Building Permit is 11010-10000-01958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71507	16041-10000-00246	19851 W NORDHOFF PL #103	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.23624	-118.56649	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHTING FIXTURES AND REPLACE WITH LED.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 4200.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71508	16041-20002-21399	19500 W PLUMMER ST SUITE E	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM			PC Approved	07/17/2017 12:00:00 AM	ADDRESS	34.2426	-118.55846	"7.17.2017 - Plan check only for modifications to approved set. Update single line diagram to reflect field changes/reality.=======Revisions to approved set of drawings - revisions made to represent (E) conditions on site regarding electrical distribution as well as associated required design changes.  (((ADDING NEW 600 AMP DISTRIBUTION BOARD ""MDPC"" TO EXISTING BOARD MDP.  PLAN CHECK FOR POWER, SHELL ONLY.  SEE NOTES:BUILDING APPLICATION # 16016-20000-11934DEMO INT. OF (E) 2-STORY RETAIL SPACE INTO (2) RETAIL SHELL SPACES AT EACH STORY.  ADD ADDITIONAL FLOOR AREA BY INFILLING (E)ESCALATOR OPENING.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71509	19041-20001-39176	15712 W DRELL ST	91342	7	222B141   268	2604014043	RS-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.30231	-118.47296	10-10-2019 Changes to an approve set of plan, Changes include addition of performance meter. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71510	17041-20000-07018	13070 W LOUVRE ST	91331	7	210B161    65	2533006005	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.27583	-118.41725	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consist of (19) modules, (19) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71511	16041-10001-12995	419 S SPRING ST	90013	14	129A211    54	5149024027	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/18/2017 12:00:00 AM	02/01/2017 12:00:00 AM		Permit Expired	06/04/2024 12:00:00 AM	ADDRESS	34.04843	-118.24885	APPLICATION FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED IN BOLD AND CLOUDED UNDER DELTA 1. CHANGE INCLUDES ADDITION OF 800A SERVICE, TRANSFORMER TO SUPPLY 480V DISTRIBUTION. PROVIDING FEEDER TO EXISTING FIRE PUMP AND REFEEDING PREVIOUS APPROVED RISER. ADDING MAN LIFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71512	18041-20000-43381	12020 RICASOLI WAY	91326	12	216B109   374	2701084024	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	PIN	34.29164056	-118.58488155	PV1.  Install roof mounted PV systen sized 12kW AC interconnected with MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71513	12041-20000-24217	10810 W PALMS BLVD	90034	11	120B161  1013	4252037033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.02	Electrical	Electrical	Apartment			10/10/2012 12:00:00 AM	01/18/2013 12:00:00 AM		Permit Finaled	01/08/2014 12:00:00 AM	ADDRESS	34.02312	-118.41412	Plan check for power and energy. New 3 floor 25 unit apartment with a fire variance.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71514	10041-10000-04965	777 E 10TH ST 1-78	90021	9	124-5A211 244	5132002028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	03/18/2010 12:00:00 AM		Permit Finaled	04/14/2010 12:00:00 AM	ADDRESS	34.03437	-118.24974	title 24 for tenant space. Also AKA unit 119.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71515	18041-10000-10867	14002 N BALBOA BLVD	91342	7	228B137   221	2603025022	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/12/2018 12:00:00 AM	ADDRESS	34.32225	-118.49057	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71516	19041-20000-17390	8724 N REMMET AVE	91304	3	195B105   208	2779041017	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	05/09/2019 12:00:00 AM		Issued	05/09/2019 12:00:00 AM	ADDRESS	34.22893	-118.60011	Plan check for power only. 800A  120/208 volt distribution equipmet, service 400A 277/480 volt. Core and shell	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71517	18041-20004-17332	6927 N REMMET AVE Unit A	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			11/15/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	11/15/2018 Changes to approved plans.  Service detail changed from 3-gang to 4-gang meter.  Relocation of equipment. (((08/02/2018 Changes to an approved set of plans. Plans updated to match revised service configuration.07/23/2018 Revision to approved set of plans.  Change of inverter from ABB-PVI-3.6-OUTD-S-US-Z-A to ABB UNO-DM-3.3-TL-PLUS-US-SZ-RA.)))(((Plan check for a PV2 roof-mounted PV system. System size is 3.6 kWac and consists of (1) inverter and (15) modules. Service size is 400 Amps.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71518	18041-20000-04879	10825 N SEPULVEDA BLVD	91345	7	207B145   135	2664013023	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Issued	02/09/2018 12:00:00 AM	ADDRESS	34.26687	-118.46769	replace existing metal hgalide fixtures with new led fixtures outdoor.  plan check for outdoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71519	14041-10000-32966	13564 W BRANFORD ST	91331	6	195B157   733	2627001022	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.23	-118.42789	PV1.  Install 4.08 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71520	18041-30000-26597	2730 N FLETCHER DR	90039	13	151-5A211  83	5436031016	[Q]C2-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Apartment			07/17/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	11/18/2018 12:00:00 AM	ADDRESS	34.11073	-118.25072	Install rooftop solar system in a commercial building,  8.6 kW AC/ 6.516 kW CEC AC, (24) modules, (12) microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71521	16041-10000-10121	9519 S CROESUS AVE	90002	15	093A217    37	6046013026	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2422.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM			Corrections Issued	03/23/2016 12:00:00 AM	ADDRESS	33.9499	-118.23415	PV1 ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS. (12) SPR-327 MODULES AND (1) INVERTER PV1-3.8-TL-OUTD. TOTAL SYSTEM SIZE IS 3.8.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71522	15041-10000-26228	3310 S MORGAN AVE	90011	9	115-5A213 190	5117010003	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	09/01/2015 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.01045	-118.24484	PV1 ROOF MOUNTED SOLAR SYTEM FOR A SINGLE HOME FAMILY DWELLING. (1) INVERTER 3.8 KW AND (11) MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71523	18041-20000-22196	10990 W WILSHIRE BLVD 4th Floor	90024	5	132B149   138	4324002027	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			06/14/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	10/08/2018 12:00:00 AM	ADDRESS	34.0577	-118.44711	Existing restroom remodel.  New lights, existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71524	14041-20001-33181	17075 W CELTIC ST	91344	12	210B133   772	2696014024	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM			PC Approved	01/02/2015 12:00:00 AM	ADDRESS	34.26937	-118.50488	EXPEDITE FEESPV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING SINGLE TRANSFORMERLESS INVERTER. NON STANDARD PLAN. SYSTEM USES POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71525	14041-10001-09381	1627 S CRESCENT PL	90291	11	108B145  1276	4241013009	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM			PC Approved	05/27/2014 12:00:00 AM	ADDRESS	33.99103	-118.46204	(((EXPEDITE FEES)))PV1 ROOF MOUNTED MICROINVERTER. SERVICE SIZE 400A. TOTAL SYSTEM SIZE 8.0KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71526	11041-10000-24007	20905 W SHERMAN WAY	91303	3	183B109    58	2112017001	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1340.01	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM			PC Approved	11/09/2011 12:00:00 AM	ADDRESS	34.20126	-118.58878	T.I. to an existing office building.  PLAN CHECK ONLY for ENERGY, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71527	18041-20000-35025	5232 E BALTIMORE ST	90042	1	154-5A225 270	5478017007	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Expired	09/13/2023 12:00:00 AM	ADDRESS	34.11776	-118.20222	Plan check for PV plus battery storage system, PV system size: 7.6kW with 12 modules and with LG Chem Resu 9.8kWh	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71528	19041-10000-41997	2960 N MARSH ST	90039	13	150B213   510	5442029900	OS-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	02/08/2021 12:00:00 AM		Permit Finaled	01/26/2023 12:00:00 AM	ADDRESS	34.10666	-118.24615	POWER PLAN CHECK FOR REPLACING VANDALIZED 2000A SERVICE, ALL DAMAGED AND OLD PANELS WITH NEW LIKE TO LIKE EQUIPMENT LOCATED IN THE SAME LOCATION . NO NEW LOAD ADDED IN THE SCOPE . ALL TENANT IMPROVEMENTS WILL BE PERMITTED SEPARATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71529	16041-10002-23236	320 S LINCOLN BLVD	90291	11	111B145   656	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.00107	-118.46691	12/28/16All changes are made under delta 10. Changes include adding one receptacle/work light. (((((((((11/14/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Revisions have been made to lighting and power layout. *****Previous Work Description*****PLANCHECK FOR POWER AND ENERGY.  FIRST TIME TENANT. RESTAURANT.  CAVA GRILL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71530	19041-20000-09205	9820 W EXPOSITION BLVD ev2	90034	5	120B165    54	4313010043	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			03/14/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.02867	-118.4016	addition of (9) EV chargers to an existing apartment building.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71531	19041-20000-50763	2255 S BARRY AVE	90064	11	123B149   467	4260013013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM			PC Info Complete	12/10/2019 12:00:00 AM	ADDRESS	34.03347	-118.44587	Plan check for Title 24 Energy for new lighting in the area, newly connected load is less than 400A. Total area: 2943 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71532	14041-10005-08514	6801 W HOLLYWOOD BLVD #170	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			PC Approved	11/20/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	Change to approved set by removing ,and adding light fixture and receptical outlets; all changes are under delta-9. (((((8/22/2014 - Changes made to approved set.  Deleted low voltage timeclock override switches 'SLV1' and 'SLV2'.  Updated lighting control riser diagram and title 24 forms to relect changes.  Changes marked with delta 8))Master permit work description:  T.I. to existing retail space for Shoe Palace.  Install new general/emergency lighting.  Plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71533	18041-20000-42203	6956 N VANSCOY AVE	91605	2	183B161   569	2324030044	R1-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/02/2018 12:00:00 AM		Issued	11/02/2018 12:00:00 AM	ADDRESS	34.19737	-118.4061	pv1install roof mounted pv system sized 4.6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71534	15041-10001-27155	4677 E WORTH ST	90032	14	135A233   328	5223002016	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM			PC Approved	10/15/2015 12:00:00 AM	PIN	34.06255797	-118.18127172	CHANGES TO AN APPROVED SET. NOTE CHANGES ON DELTA 1. MAJOR CHANGES INCLUDE DIFFERENT FIXTURE TYPE, CORRECTED VOLTAGE CLASS, CHANGE OF CIRCUITS AND T-24 CALCULATIONS. PC for energyonly, T-24 for a commercial werehouse. The scope of work includes the addition of receptacles, and light fixtures. 1 new panel (400 amps).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71535	17041-10000-11861	515 S FIGUEROA ST Suite 102	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	09/20/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	PC FOR ENERGY ONLY. CHANGE OF USE FROM OFFICE TO GYM. CONNETED LOAD <400A . TOTAL AREA 2936 SQ FT.B# 17016-10000-03256.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71536	18041-10001-47415	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM			PC Approved	01/11/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	SUPPLEMENT TO AN APPROVED SET. SCOPE FEEDING THE LOAD FROM MSNE(E) INSTED OF MSNW AND ADDING A 400AMP TRANSFER SWITCH. CHANGES ARE MARKED DELTA 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71537	17041-20001-44114	11749 N CHIMINEAS AVE	91326	12	216B125   312	2870019032	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM			PC Approved	12/20/2017 12:00:00 AM	ADDRESS	34.28453	-118.5333	Expedited plan check fee. PV1.  Install 13.2 kW roof mounted grid tied PV system.  (48) modules with (2) central inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71538	18041-10001-06409	5435 N YARMOUTH AVE	91316	5	174B129   999	2162010***	R3-1	South Valley	Encino - Tarzana	Encino		1395.04	Electrical	Electrical	Commercial			02/21/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.16959	-118.52046	EXPEDITE PER APPLICANT REQUEST. PC FOR ROOF MOUNTED PV ON APARTMENT BUILDING. TOTAL SYSTEM SIZE 14.82KWDC/13KWAC.SCOPE INCLUDES 52 MODULES (285W) WITH 52 MICROINVERTERS (250W)  AND NEW LOAD CENTER.SEE NOTE*	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71539	12041-20000-26101	6500 W WILSHIRE BLVD 19TH FLOOR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.06371	-118.3703	Plan check for energy and emergency lighting. 19th floor. 7530 sqft. Commercial high rise.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71540	19041-10000-51066	7931 N JAMIESON AVE	91335	12	189B129   589	2101029018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	05/18/2020 12:00:00 AM	ADDRESS	34.21459	-118.52236	PV1. NEW SOLAR SYSTEM SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.82KWdc / 6.0KWac.(22)MODULES-CANADIAN SOLAR 310 MODULES(1)INVERTERS- SOLAREDGE SE6000H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71541	13041-20001-17274	17643 W ROMAR ST	91325	12	204B129   567	2734012057	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	08/02/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	34.25503	-118.5193	New PV rooftop system using Microinverters.  sfd( supp application for new arrangment of modules and addition of subpanel. ))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71542	16041-20000-30321	6530 W SUNSET BLVD	90028	13	147A187   163	5547026024	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.09782	-118.3326	Plan check for power and energy (power plan check requested by applicant). TI of existing Urm restaurant. New lighting (incl. emergency), restaurant equipment, receptacles, and panelboards. 4,901sqft. Permit already pulled under application #16041-20000-24743.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71543	18041-10000-19970	12885 W NORTH SEAGLASS CIR	90094	11	102B157   398	4211037142	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.9741	-118.42006	New PV1 rooftop Solar system 7.6 kW AC/ 8.125 kW DC with ESS (on separate application# E18LA02431), (25) modules with optimizers, (1) inverter, (1) 200 A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71544	16041-20000-08977	3020 W WILSHIRE BLVD	90010	10	132B197    30	5077013038	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.06165	-118.28725	"""$0 permit fees due to senate bill 1222 ""PV2. ROOFMOUNTED SOLAR SYSTEM.  FEED IN TARRIF.  SYSTEM SIZE: 168 KW."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71545	09041-10002-22451	525-531 W 7TH ST	90731	15	015B197   553	7454003009	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			04/10/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	ADDRESS	33.73765	-118.28849	PLANS REVISED DURING CONSTRUCTIO:FEEDERS FOR THE SPA AND STEAM UNITS HAVE BEEN CHANGED TO ALUMINUM CONDUCRORS; SPA UNIT IS A 3PH LOAD;ADDED A FIEW CKTS;REVISED LIGHTING SYSTEM AND COMPLIANCE FORMSChanges from previously approved plans.  Changes in lighting and load.  Plan check for energy and power.panel c was added with all 29 branch cktsnew.*****TENANT IMPROVEMENT AND STRUCTURAL ALTERATIONS TO CONNECT TWO BLDGS AND CHANGE OF USE FROM RETAIL/ RESTAURANT TO MEDICAL CLINIC WITH PHYSICAL THERAPY ROOM.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71546	10041-20000-20977	3900 N STANSBURY AVE Triangle-Building	91423	5	162B153   353	2274027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	34.14084	-118.44264	Plan check power and energy for new triangle building at Buckley school. Modification to seperate fire alarm systems had been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71547	19041-10000-50684	7424 W WOODROW WILSON DR	90046	4	156B177   295	2427014035	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	01/08/2020 12:00:00 AM		Permit Expired	10/31/2022 12:00:00 AM	ADDRESS	34.12408	-118.35616	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 13.86KWdc (11.4KWac) USING 42 VBHN330SA17 MODULES, 42 SE P400 POWER OTIMIZERS & 1 SE-11400H-US CENTRAL INVERTER.CONNECTED TO A 400 AMP EXISTING SERVICE. MAIN BREAKER TO BE DERATED TO 175 AMP UNDER SEPARATE PERMIT.Due to senate bill AB 1414 $0 is accepted.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71548	17041-10000-06873	1212 W 58TH ST	90037	9	108B197  1383	5002015009	[Q]CM-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.98976	-118.29647	PC for indoor title 24 only. Removing HID fixutres with new LED fixutres. Area: 23,525 sq ft. .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71549	17041-20001-07879	17270 W DEVONSHIRE ST	91325	12	204B133   195	2694015006	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.2574	-118.51061	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71550	16041-20000-13565	7458 N BALBOA BLVD	91406	6	186B133  1160	2226028020	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2016 12:00:00 AM	04/19/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.2063	-118.50086	PV1. ROOFMOUNTED SOLAR SYSTEM. 7.8 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71551	18041-20001-15986	8531 N FALLBROOK AVE 1st & 2nd-Floor	91304	12	192B097   582	2005022001	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.22425	-118.62931	09-28-2018 Changes to approved set of plans - changes include lighting revisions and Title 24 calculations, site plan updates, single line revisions.  All changes have been clouded as delta 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71552	11041-10000-25272	4728 S LINCOLN BLVD Unit A	90292	11	105B153   149	4224014018	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/28/2011 12:00:00 AM			PC Approved	12/14/2011 12:00:00 AM	ADDRESS	33.97993	-118.43802	PLAN CHECK ONLY FOR ENERGY, with Emergency lighting.>>>>CHANGE OF USE FROM RETAIL TO MASSAGE  PARLOR WHERE ANY PERSON WHO PROVIDES MASSAGE SERVICES AT THIS PREMISE SHALL BE CERTIFIED AS A MASSAGE THERAPIST OR MASSAGE PRACTITIONER PURSUANT TO CALIFORNIA BUSINESS AND PROFESSIONS SECTION 4600 ET SEQ. (THERAPIST CALIFORNIAL LICENSE # 5043)>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71553	13041-10001-00089	746 S CENTRAL AVE	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.03537	-118.24198	"updating the plans to show the emergency lightingLIGHTING FOR STAIRWAY T242 STORY PRODUCE MARKET T24""COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71554	17041-10000-39859	114 W 4TH ST	90013	14	129A211    69	5149022013		Central				2073.02	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	03/01/2018 12:00:00 AM	ADDRESS	34.0483	-118.24775	T-24, TI TO AN EXISTING MUSEUM SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLE. TOTAL SQ. FT. 3650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71555	19041-10000-36252	12121 W JEFFERSON BLVD	90230	11	105B161   910	4220007050	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	33.98228	-118.40792	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71556	09041-20002-13618	19755 W VANOWEN ST #A-2-#A-28	91306		183B117   835	2135022005	(T)(Q)C4-1VL		Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka			Electrical	Electrical	Commercial			10/28/2011 12:00:00 AM			Corrections Issued	11/06/2011 12:00:00 AM	ADDRESS	34.19397	-118.56386	New retail building.  Install new 1200 Amp service, panels, branch circuits, and lighting.  Plan check for power and energy for core & shell.to replace lost plans existing permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71557	15041-20001-32730	5220 N CALENDA DR	91367	3	171B093   436	2044020032	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			Reviewed by Supervisor	10/13/2015 12:00:00 AM	ADDRESS	34.16462	-118.63626	Expedited per customer request.PV1. Install roof mounted PV system sized 11.4 kW. Interconnected with main service panel.(52) Kyocera KU 265 Modules(1) Solaredge SE11400	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71558	16041-10000-03679	300 S GRAND AVE 40TH FLR-CORRIDOR	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Issued	11/04/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 40TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES ON CORRIDOR. TOTAL AFFECTED AREA IS 1076 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71559	13041-10000-02351	11725 N HUNNEWELL AVE	91342	7	213B165   172	2531032029	[Q]RZ5-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1042.04	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2013 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	08/26/2013 12:00:00 AM	ADDRESS	34.28326	-118.4002	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY TWO STORY DWELLING. TOTAL SYSTEM SIZE OF 4.75KW. USING 22 MODULES. ENPHASE M215-60-2LL-S22 MICROINVERTER. SOLAR PANEL REC 245 PE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71560	17041-10000-13675	7130 W SUNSET BLVD	90046	4	147B181   685	5548017050	C4-1VL-SN	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			05/09/2017 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	10/13/2020 12:00:00 AM	ADDRESS	34.09776	-118.34491	Plan check for power and energy.  New 4 story 60 unit apartment building.  New 2,000 amp 120/208 volt service.  Total energy area is 61,112-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71561	12041-10000-30096	5117 E RANGE VIEW AVE	90042	14	156A225     9	5479026019	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.12362	-118.20338	PV1:  New 4.8 KW roof mounted PV system.  Installing 20 modules, 1 inverter (transformerless).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71562	12041-10000-17388	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			07/25/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	02/12/2013 12:00:00 AM	ADDRESS	34.05855	-118.23671	TENANT IMPROVEMENT-NEW UPS SYSTEMS AND DISTRIBUTION EQUIPMENT IN EXISTING COMPUTER ROOM ON THE 3RD FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71563	15041-10001-02146	15102 W GREENLEAF ST	91403	4	166-5A147 144	2276021001	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2015 12:00:00 AM			PC Approved	02/06/2015 12:00:00 AM	ADDRESS	34.15045	-118.46239	PV system size: 14kW. 2 inverters (8kW and 6kW). 49 modules (28 and 21). 100A subpanel. 225A main service panelExpedited per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71564	19041-10000-32563	8405 W MELROSE PL	90069	5	141B173   440	5528002029	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			08/20/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	04/08/2021 12:00:00 AM	ADDRESS	34.08377	-118.37338	T-24 PLAN CHECK FOR AN INTERIOR TENANT IMPROVEMENT OF (E) RETAIL SPACE (NO CHANGE IN USE). SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 1107SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71565	19041-10000-16510	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	04/21/2020 12:00:00 AM	ADDRESS	34.04337	-118.23442	Energy plan check for a change of use from retail to office located in the 4th floor of a commerical building. Scope includes new lighting and equipment with a total floor area of 10,268 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71566	16041-20000-18019	18473 W DEVONSHIRE ST	91325	12	204B125   156	2731016003	C2-1VL	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	09/09/2016 12:00:00 AM	ADDRESS	34.25749	-118.5356	Installation of (N) lighting in addition of magazine stand.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71567	16041-20000-40145	14140 W LEMAY ST	91405	2	180B153   345	2237009018	R1-1-HPOZ	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.19184	-118.44143	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71568	18041-20000-03421	11937 N RICASOLI WAY	91326	12	216B109   332	2701085013	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM			Reviewed by Supervisor	02/06/2018 12:00:00 AM	ADDRESS	34.28986	-118.58501	pv1install roof mounted pv system sized 14.2kw  with (2) tesla powerwalls rated at 5kw each.  plan check for power.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71569	13041-20000-17783	22470 W DOMINGO ROAD	91364	3	168B101   191	2075038013	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM	07/24/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.15918	-118.61609	PV1 FOR TRANSFORMERLESS INVERTER WITH POWER OPTIMIZER. TOTAL SYSTEM SIZE: 5.83KW. 22 MODULES AND 1 INVERTER. PERMIT INCLUDES SERVICE AND PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71570	19041-10000-17112	355 S GRAND AVE 22nd FLOOR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/15/2019 12:00:00 AM		Permit Finaled	02/20/2020 12:00:00 AM	ADDRESS	34.05191	-118.2525	PLAN CHECK FOR TITLE 24 ONLY. INTERIOR REMODEL ON 22ND FLOOR: CORRIDOR, ELEVATOR LOBBY AND RESTROOMS TOTAL EFFECTED AREA 2673 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71571	10041-20000-06042	746 S CENTRAL AVE #A3 BLDG.	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Expired	09/06/2012 12:00:00 AM	ADDRESS	34.03537	-118.24198	Second floor fire damageEnergy, exit signs	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71572	11041-10000-10794	6928 N OWENSMOUTH AVE	91303	3	183B105   755	2138007027	P-1VL, [Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			05/25/2011 12:00:00 AM			Reviewed by Supervisor	02/24/2012 12:00:00 AM	ADDRESS	34.19636	-118.60139	NEW ROOF TOP PV SYSTEM FOR 2-STORY COMMERCIAL BUILDING.  31.74 KW SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71573	14041-10000-21199	4750 W WILSHIRE BLVD	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.06185	-118.3338	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. OUTDOOR LIGHTING. 15560 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71574	19041-20000-45035	3672 S JASMINE AVE 1-17	90034	5	120B165   936	4313003029	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			11/04/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	05/24/2022 12:00:00 AM	ADDRESS	34.02438	-118.40378	INSTALL (100) FIRE ALARM DEVICES AND (1) PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71575	17041-20001-30881	12316 W LULL ST	91605	2	186B165   178	2307016014	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.20927	-118.40147	PV1.  Install 11.04 kW DC (10.24 kW AC) roof mounted grid tied PV system.  AC modules.  Derating main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71576	14041-10000-28758	416 E BOYD ST	90013	14	129A213   355	5147006001	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.04606	-118.24212	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR A RESTAURANT.NO CHANGE IN OCCUPANCY. 3650 SQFT, EMERGENCY LIGTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71577	12041-10001-30230	5857 S CENTRAL AVE	90001	9	108B209  1518	6007003902	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	33.98813	-118.25672	Delta-7 changes to approved set.  Removal of panel in space 195, tenant pending.  Changes to RTU loads on some unit panels.  SHOP BUILDING (RETAIL) . PLAN CHECK FOR power and energy, core & shell.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71578	13041-20000-32744	9601 N MASON AVE Unit A	91311	12	201B109   284	2748003080	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	34.24457	-118.57997	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING WAREHOUSE. ADDING NEW LIGHTING AND NEW POWER EQUIPMENT LOAD AND 150KVA TRANSFORMER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71579	18041-20000-48292	637 W 77TH ST	90044	8	099B201   199	6020019015	[Q]R3-1	South Los Angeles	South Los Angeles			2377.20	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	33.96989	-118.28532	PC FOR NEW ROOFTOP 7.6KW AC PV SYSTEM, (18) DC MODULES, (18) P320 OPTIMIZERS, 1 7.6 KW AC SE7600A-USS2 INVERTER, (1) 5 KW ENERGY STORAGE SYSTEM, (1) NEW 5KW AUTOTRANSFORMER, (1) NEW 200A PANEL, AND (1) NEW 100A PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71580	10041-20002-12743	13261 W EUSTACE ST	91331	7	213B157   514	2524028019	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			05/19/2011 12:00:00 AM			PC Approved	06/07/2011 12:00:00 AM	ADDRESS	34.27921	-118.42186	PLAN CHECK FOR 35.88KW ROOF MOUNTED PHOTOVOLATAIC SYSTEM FOR CHARTER SCHOOL. EXISTING PERMIT. PLAN CHECK UNDER NEC 2008. EXISTING PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71581	15041-10002-20586	1455 N VAN NESS AVE	90028	13	147A191   102	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	34.09728	-118.31598	01/06/16Changes to an approved set. All changes made under delta 3. Scope includes adding a new 100A panel and relocating load equipment (heat generator engines). ((((01/04/16Changes to an approved set. All changes made under delta 2. Scope includes changes in conduit sizes, feeder sizes, and relabling transformers.Note: Permit pulled under PCIS#15041-10000-20586((((PC FOR POWER. UPGRADING 2 OPTIONAL STANDBY 750 KW AC GENERATOR AND ADDING NEW 1200 A SWITCHBOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71582	18041-10000-47191	2315 W MARTIN LUTHER KING, JR BLVD	90008	10	114B189   316	5034019052	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM			Ready to Issue	11/26/2019 12:00:00 AM	ADDRESS	34.01097	-118.31882	Full plan check for a change of use from a chuch  TO A  LGBT CENTER AND CLINIC. Scope includes new lighting and equipment with a total area of 2300-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71583	15041-10000-23969	1641 N IVAR AVE	90028	13	148-5A187 207	5546008022	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.10097	-118.3283	TI FOR EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTING AND POWER LESS THAN 400A. PC FOR ENERGY ONLY. TOTAL AREA = 6902 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71584	18041-10000-22754	12843 W MUSCATINE ST	91331	6	198B161   248	2629027029	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Issued	06/19/2018 12:00:00 AM	ADDRESS	34.23929	-118.41288	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71585	18041-10000-25805	10250 W SANTA MONICA BLVD #2530	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71586	19041-10000-06215	11352 N EL DORADO AVE	91340	7	213B153   232	2616018020	M1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Closed	02/07/2024 12:00:00 AM	ADDRESS	34.27647	-118.43584	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71587	14041-20001-27997	150 E 61ST ST	90003	9	105B205   653	6006010002	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM			PC Approved	10/31/2014 12:00:00 AM	ADDRESS	33.98405	-118.27207	EXPEDITE PER APPLICANT REQUESTPV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71588	14041-10000-27933	7909 W ROSEWOOD AVE	90048	5	141B177  1153	5527020009	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	03/11/2015 12:00:00 AM	ADDRESS	34.08022	-118.36192	Title 24 plan check only.  Total area = 1272 sq. ft.T.I. to existing retail space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71589	17041-20001-24598	18535 W CALLE VISTA CIR	91326	12	216B125   278	2872012009	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.28489	-118.53771	Expedited plan check fee per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71590	14041-10000-15080	1500 N EL CENTRO AVE	90028	13	148-5A189 301	5546026029	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Finaled	03/20/2017 12:00:00 AM	ADDRESS	34.09917	-118.32359	New fire alarm system for existing commercial space.Total system size = 194 devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71591	19041-10000-48669	1103 S ABBOT KINNEY BLVD	90291	11	108B145  1025	4239022002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			11/25/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Issued	01/30/2020 12:00:00 AM	ADDRESS	33.99185	-118.47029	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS A TI, SCOPE OF WORK INCLUDES NEW LIGHTING,CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2780 SQFT. NOTE THIS PLAN CONTAINS AREA CATEGORY METHOND WITH TAILORED METHOD LIGHTING AS WELL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71592	11041-10000-07654	2269 W WASHINGTON BLVD	90019	10	126B193   914	5073014010	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Apartment			04/15/2011 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	03/07/2012 12:00:00 AM	PIN	34.04015612	-118.31130248	SERVICE UPGRADE TO AN EXISTING APARTMENT BUILDING.  13 - 200A PANELS AND ADDITIONAL OUTLETS TO MEET CODE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71593	18041-20003-13383	6180 N LAUREL CANYON BLVD	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			Corrections Issued	10/11/2019 12:00:00 AM	ADDRESS	34.18261	-118.39631	PLAN CHECK ONLY, SCOPE OF WORK INCLUDES REVISON OF LOADS TO PANEL SCHEDULE AND ADDITION OF NEW FIXTURES. ___________________________________________________Buildings supplied through 34.5 kV loop distribution (under separate permit).  Plan check for power and energy.  Associated building permits under 16010-10000-05907/05917/05918/05919/05920.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71594	18041-20000-45112	19843 W GILMORE ST	91367	3	180B113   723	2134027008	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Issued	11/27/2018 12:00:00 AM	ADDRESS	34.1876	-118.56584	Plan check for PV roof mounted system install with existing PV system, Addition PV system size: 11.88kW with 33 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71595	15041-10002-10142	5860 W JEFFERSON BLVD	90016	10	120B173  1729	4205027022	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.02504	-118.37633	02/13/16Changes to an approved set of plans. All changes are clouded under delta 2 & 3. Changes include refeeding panels from temporary service to an existing 5000A distribution board, replacing outdoor lighting fixtures, and revising title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71596	17041-10000-39645	611 S GAFFEY ST	90731	15			[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM			PC Approved	11/02/2017 12:00:00 AM	ADDRESS	33.73846	-118.29252	TENANT IMPROVEMENT (TI) OF AN EXISTING RESTAURANT AND FISH MARKET  FOR A NEW WABA GRILL FAST FOOD RESTAURANT.PLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71597	15041-20000-21372	13039 W VICTORY BLVD	91606	2	180B161   790	2326017***	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	10/02/2015 12:00:00 AM	ADDRESS	34.188	-118.41653	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor canopy lighting. Total lighting area = 4,050 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71598	12041-20002-25511	10840 W WILSHIRE BLVD	90024	5	132B153   401	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	ADDRESS	34.05924	-118.44131	[[[[[PLAN CHECK ONLY. ]]]]]CHANGES TO APPROVED SET. ADDITION OF TWO ROOF MOUNTED REFRIGERATOR AND COMPRESSOR RACKS. ADDITION OF FEW ADDTIONAL CKTS. DELTA 21 CHANGES ONLY. ALL CHANGES ARE CLOUDED.B OCCUPANCY, EMERGENCY EXIT AND LIGHTING REQUIRED. PROPOSED ADDITION AND REMODEL TO PORTION OF EXISTING BLDG- CONVERTING A PORTION OF EXISTING THEATER TO A RESTAURANT AND BAR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71599	13041-20000-23466	10875 N SAN FERNANDO ROAD	91331	7	207B157    70	2619016036	CM-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			08/28/2013 12:00:00 AM			Reviewed by Supervisor	09/20/2013 12:00:00 AM	ADDRESS	34.26767	-118.42409	NEW CONSTRUCTION OF AUTO REPAIR SHOP. NEW 600A SERVICE. FULL PLAN CHECK. POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71600	11041-10000-20939	12050 W VENTURA BLVD B201	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			10/04/2011 12:00:00 AM	01/18/2012 12:00:00 AM		Permit Finaled	03/17/2012 12:00:00 AM	ADDRESS	34.14349	-118.39426	New health club in existing space.  Energy and electrical plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71601	13041-10001-10721	24015 W NORDHOFF ST	91311	12	195B113    79	2781001052	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	ADDRESS	34.23202	-118.57795	Supplemental description: FACP and annunciator relocated, replacement of second story smoke detector with single heat detector, and addition of one smoke detector for building server room. Original work description:  New fire alarm system for 2-story commercial bldg.  49 devices and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71602	14041-10001-15689	13615 W DEBBY ST	91401	2	177B157   241	2330011002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.18401	-118.42976	EXPEDITE FEES ONLYROOFTOP SOLAR PV SYSTEM INSTALLATION.  TOTAL SYSTEM SIZE = 6.4 kW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71603	18041-10000-35948	11100 W SANTA MONICA BLVD SUITE 1200	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI IN AN EXISTING OFFICE AREA IN PORTION OF SUITE # 1200. T-24 ENERGY ONLY - 1,795 SFT. BLDG PERMIT: 18016-10000-28310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71604	13041-20000-02101	5653 N SHIRLEY AVE PV-1	91356	3	174B117   691	2153026027	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.17417	-118.55855	"PV-1. Plan check for PV system. 18.56kW. Main service panel upgrade will be included in ""Inpection"" fee period."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71605	19041-20000-26200	5550 N BONNER AVE	91601	2	174B173  1076	2350005052	R4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Apartment			07/09/2019 12:00:00 AM			PC Approved	07/09/2019 12:00:00 AM	ADDRESS	34.17145	-118.37398	7/9/2019changes to an approved set of plans.  changes to relocate service equipment.  this i splan check only.  changes noted delta 2. this application number is tied to 15041-20001-37430((((12/19/2017changes to an approved set of plans.  changes are noted delta 1.  changes include redesign of common area layouts, energy calculations, and lighting.  updated fault current from utility and new AIC ratings for equipment.))))      (((((Plan check for power and energy. Project site is a new 5-story, 48-unit apartment building with (1) level of subterranean parking garage. Total lighting area = 40,475 sq. ft.Note: Building application has been created under 16010-10000-00385)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71606	11041-10000-01484	515 E 6TH ST	90013	14	127-5A213 466	5147024023	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	10/07/2011 12:00:00 AM	PIN	34.04218875	-118.24483426	New fire alarm system for a highrise building. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71607	16041-10003-18232	8500 N BALBOA BLVD	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.22485	-118.50045	Changes to an approved set of plans. Adding EV monitors and irrigation controllers. All changes clouded under delta 3 and 4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71608	12041-10000-20983	3838 N LANKERSHIM BLVD 3RD LEVEL	90068	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			09/05/2012 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	03/08/2013 12:00:00 AM	ADDRESS	34.13829	-118.36225	(((((((    7 days meter reading provided , variance filed  to bring the other 23 days of meter readind.  2-28-13))))))))COVERT EXISTING OFFICE TO CAFE/BAKERY AND COMBINE WITH ADJACENT EXISTING CAFE TENANT(~3710 S.F.)-ALL ON THE 3RD LEVEL OF AN EXISTING 6-STORIES PARKING STRUCTURE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71609	16041-10000-18776	801 S BERENDO ST	90005	10	132B197   464	5094014001		Central				2123.06	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	09/09/2021 12:00:00 AM	ADDRESS	34.05753	-118.29435	Methane detecting system for a commercial buiilding. Scope includes 22 devices and 2 control panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71610	18041-10000-28541	1315 W COLTON ST	90026	1	135A209   281	5160019003	CW	Central	Westlake	Greater Echo Park Elysian	YES	2080.00	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM			PC Info Complete	09/06/2018 12:00:00 AM	ADDRESS	34.06323	-118.257	INSTALLATION OF ONE LEVEL-V METHANE SYSTEM. (1) panel, (13) devices**REDUNDANT PLAN TO PLAN CHECK # 22041-10000-558241**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71611	14041-20000-31322	1926 E 7TH ST	90021	14	124-5A217 252	5166016005	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/12/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.03446	-118.23293	PLANCHECK FOR ENERGY. TENANT IMPROVEMENT. LIGHTING FOR RESTROOMS (213 SQFT)  AND INSTALLTION OF 2 PANLES.  NO CHANGE IN OCCUPANCY PER APPLICANT. < 400 AMPS NEWLY CONNECTED LOAD. PANEL HP TO BE SPLIT BUS PANEL .TI to (E) manufacturing space.New restrooms and roof top AC unit supprot.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71612	19041-10000-48214	11401 W SANTA MONICA BLVD	90025	11	129B149   497	4261003009	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	07/16/2020 12:00:00 AM		Permit Finaled	09/30/2021 12:00:00 AM	ADDRESS	34.04602	-118.4512	Full plan check for first time tenant improvement to a core and shell store. Scope includes new circuits, receptacles, lighting and controls. Total affected area is 1542 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71613	15041-20000-05904	1786 W 37TH ST	90018	8	117B193    36	5041024003	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.02093	-118.31153	Plan check for PV1 roof mounted 3.4 kW with 16 module micro-inverters.Note: PV plan submit over the counter because B contractor can not pull permit online	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71614	11041-20000-07231	11666 W NATIONAL BLVD	90066	11	120B153  1008	4250008020	C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	ADDRESS	34.02276	-118.43815	plan was checked for energy only but it exceeded 400 A inspector needed complete plan check.  Energy -Title 24 been approved under plan check number 11041-10002-00384..  One tenant (Whole Food) under the main meter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71615	17041-10000-36251	1297 W SEPULVEDA ST	90732	15	018B193   657	7452006001	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Issued	10/10/2017 12:00:00 AM	ADDRESS	33.74504	-118.30406	INTERIOR ALTERATIONS -REPLACE HID WITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71616	11041-20000-27348	2029 S CENTURY PARK EAST 515	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM			PC Approved	12/23/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T24 and emergency lighting plan check for remodeled space 515.  Most luminaires existing added occupancy sensors to existing offices.  This is an alteration to existing lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71617	16041-20000-24480	700 S FLOWER ST 21st Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Issued	07/19/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI to (E) commercial highrise common area on 21st floor.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71618	12041-20000-02531	300 S GRAND AVE portion of-32nd fl	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM	03/12/2012 12:00:00 AM		Permit Finaled	03/14/2013 12:00:00 AM	PIN	34.05243427	-118.25124731	T24 lighting plan check for a portion of the 32 floor.  Lighting alteration.  <<FEES FOR PERMIT ARE UNDER INSPECTION.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71619	18041-20000-28976	1135 N MANSFIELD AVE 2nd flr	90038	4	144B181   376	5532017019	M1-1VL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Issued	08/07/2018 12:00:00 AM	ADDRESS	34.0918	-118.34057	ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71620	14041-10000-12622	8234 N VANSCOY AVE	91605	2	192B161   196	2308005008	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Finaled	08/05/2014 12:00:00 AM	ADDRESS	34.22082	-118.40616	PV1, INSTALL 3.06 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER. TRANSFORMERLESS INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71621	13041-10002-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Approved	04/01/2015 12:00:00 AM	ADDRESS	34.09649	-118.33888	Changes made to approved plans.  Revised lighting controls for common areas, change from electric to gas range/oven, delta-13 changes only.  (((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71622	17041-10000-25101	5970 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	33.94286	-118.38634	PC FOR POWER originally for hazardous  location for installation of Diesel pump. 7/25/2017Per architect and manufacter specs, this is Diesel Exhaust Fluid (non hazardous) dispenser. permit for one circuit for the pump. 8/8/2017	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71623	17041-10000-28873	1473 E 4TH ST 107, 108	90033	14	127-5A219 306	5172020019	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM			PC Info Complete	08/15/2017 12:00:00 AM	ADDRESS	34.04268	-118.22471	TI TO WAREHOUSE/OFFICE SPACE. NEW LIGHTING IN OFFICE AREAS AND RESTROOMS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71624	14041-10001-04164	1741 W KENT ST	90026	13	138A207    42	5404006021	RD2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.07377	-118.26295	EXEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 6.5 kW DC roof-mounted solar array on a two-story home, interconnect with main service panel. (1)Transformerless inverter: Solaredge SE 6000A-US-ZB-U. (26) Modules: CANADIAN SOLAR CS6P-250PX.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71625	16041-20000-32540	4151 W PROSPECT AVE BLDG X-STAGE 4	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Issued	10/04/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	PLAN CHECK FOR POWER PER APPLICANT REQUEST.  ADDING NEW SHUT TRIP FOR EXISTING ELEVATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71626	10041-10000-23450	19481 S HARBORGATE WAY	90501	15	057B193    21	7351021016	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM	02/24/2011 12:00:00 AM		Permit Finaled	05/02/2011 12:00:00 AM	ADDRESS	33.85326	-118.30372	50kw interactive photovoltaic system on roof of a commercial building.  Inspector please verify if proper system grounding has been provided.  Designer indicates that the system grounding is per code for his equipment.  If there are any groudning issues, please refer back to plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71627	15041-20000-07292	3978 N FREDONIA DR	90068	4	159B177    59	2380001006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	04/27/2015 12:00:00 AM	ADDRESS	34.13562	-118.36608	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (17) modules and (1) inverter. Standard plan is NOT being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71628	17041-20000-35828	16509 W KNOLLWOOD DR	91344	12	219B137   103	2609013003	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM	10/05/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	ADDRESS	34.29527	-118.49583	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (33) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71629	15041-20003-26937	12954 W CORCORAN PL	91340	7	216B161   108	2514010050	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.28959	-118.41511	04/04/2016 Plan check for a lost set of plans. PV system has remained the same.*****Previous Work Description*****Expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  Single inverter system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71630	12041-10000-22314	7936 N SEDAN AVE	91304	3	189B097   509	2014029001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.21483	-118.62996	PLAN CHECK FOR ROOF-MOUNTED  3.9KW PHOTOVOLTAIC SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71631	10041-20000-21176	110 S FAIRFAX AVE #380	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	10/25/2010 12:00:00 AM		Permit Finaled	11/19/2010 12:00:00 AM	ADDRESS	34.07371	-118.36119	Plan check T24 Energy general and emergency lighting for suite #380.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71632	14041-20000-20643	7257 N CLAIRE AVE	91335	3	186B121   989	2104032024	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.20272	-118.55039	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(12) POWER ONE PVI-3.8 MODULES(1) AURORA 3.8 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71633	15041-10001-43827	8500 W BEVERLY BLVD FOOD HALL	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/31/2016 12:00:00 AM	07/08/2016 12:00:00 AM		Permit Finaled	02/06/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	Changes to approved set under Delta-5, scope of work on FH- Food Hall Level 8.1. Revised feeder connection inside TMSBA2. Added 10.5 Elevator from EDRB panel3. Relocate HPU's 4. Reconnect Dry type Trnasformer from ERB to EDRB5. Relocate branch circuits.(Preview by A.F)<<PC FOR POWER AND ENERGY. NEW DISTRIBUTION EQUIPMENT FOR FUTURE TENANTS. MALL IS GUTTING AND RENOVATING 8TH FLOOR FOOD HALL. ASSOCIATED HOUSE LOADS AND EQUIPMENT INSTALLED AT THIS TIME. PC FOR POWER AND ENERGY. PC FOR AREAS DESCRIBED AS FH - FOOD HALL>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71634	13041-10000-13867	824 S FRANCISCO ST	90017	14	129A207   124	5144022035	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM	08/22/2013 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.04795	-118.26326	T.I. to existing parking structure.  Install new 600A service, new switchboard, 25KW generator, and parking light.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71635	17041-20001-38135	23029 W SCHOOLCRAFT ST	91307	12	183B097   501	2026013013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.19699	-118.62879	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.Total system size: 11.4kW ungrounded.(1) 11.4kW SolarEdge inverters(32) 325W pv modules.(32) 400W power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71636	10041-10000-25635	1350 W SHATTO ST	90017	1	132A205   255	5143015019	CW	Central	Westlake		YES	2091.02	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.05515	-118.26771	Relocating MRI machine in the Good Samartan Hospital. Instaling a new 600 Amp service, board, and X-former. EPC is for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71637	19041-10000-53578	6106 W SUNSET BLVD	90028	13	147A189    58	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.09785	-118.32275	PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN OFFICE SPACE. TOTAL SQ. FT. 1539	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71638	14041-10002-11720	2512 S WESTWOOD BLVD	90064	5	126B157  1115	4255026002	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.03878	-118.42719	"$0 submittal fee is due to the 2012 Senate Bill No. 1222"" Plan check only.(((8/15/2014 - Supp. app. for change of breaker size for main service panel which is center fed)))Master Permit work description:  PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZEER. 18 MODULES. 1 INVERTER."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71639	18041-10000-18966	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM			PC Info Complete	05/24/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	**** WORK IN SOUTH WEST LOUNG???*****REVIEW AND REVISE WORK DESCRIPTION. PC FOR OFFICE TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA2309 SQ.FTB# 18016-10000-11639	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71640	15041-10002-01076	12518 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	33.97836	-118.41209	((((5/10/2015))))  REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES ARE NOTED DELTA 2 ON THE PLANS.  CHANGES INCLUDE REVISIONS TO ENERGY CALCULATIONS, OCCUPANCY SENSORS AND LIGHTING SWITCHES.  THE CHANGES APPLY TO ALL THE FOLLOWING APPLICATION NUMBERS AS NOTED BELOW.Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71641	15041-20002-39378	20790 W NORDHOFF ST Space 3	91311	3	198B109   218	2355012065	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	34.23523	-118.58748	Revisions to approved plans.  Reduction of load to 200.0 A.   (((TI for (E) commercial space for new 1208 sq ft yogurt shop.  Plan check for energy.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71642	16041-20000-37557	16708 W HORACE ST	91344	12	210B137   692	2683012007	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.26998	-118.49602	pv1install roof mounted pv system sized 7.6kw interconnected with msp. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71643	18041-20000-33214	12254 W VENTURA BLVD	91604	2	162B165   242	2369004024	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	08/09/2019 12:00:00 AM	ADDRESS	34.14288	-118.40038	Plan check for Title 24 Energy only in existing restaurant  T.I.  Total area: 1178 sq ft. B#18016-20000-24879	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71644	17041-10000-10639	1318 E 7TH ST STE 260	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.03608	-118.24052	PC FOR TENANT IMPROVEMENT IN COMM. BUILDING ON SECOND FLOOR. TOTAL CONNECTED LOAD LARGER THAN 400A. TOTAL AFFECTED AREA 24869 SQ.FT.BUILDING APP # 17016-10000-06981	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71645	15041-10000-20124	3329 W SUNSET BLVD	90026	13	144A203   356	5426006008	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM			PC Info Complete	06/29/2015 12:00:00 AM	ADDRESS	34.08729	-118.27551	PC FOR ENERGY. SINGLE STORY COMMERCIAL BUILDING. ADDING NEW LIGHTS AND CONTROL AND PANELS, NEW LOAD IS LESS THAN 400 A. TOTAL AREA 5151 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71646	13041-20000-11920	21600 W OXNARD ST #200	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM	05/08/2013 12:00:00 AM		Permit Closed	05/01/2015 12:00:00 AM	ADDRESS	34.179	-118.6002	RENOVATION OF OFFICES. REPARTITIONING OF SPACES. ADDED LOAD < 400A. PC FOR ENERGY ONLY T24. PERMIT TO BE ISSUED FROM THIS APPLICATION. TOTAL AREA 5153 SQ FT. EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71647	12041-10000-13988	3630 S MENTONE AVE	90034	10	120B161   909	4314008015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.02	Electrical	Electrical	Apartment			06/15/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	06/18/2013 12:00:00 AM	ADDRESS	34.02361	-118.40774	NEW 10 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71648	13041-10002-32074	1945 W 26TH ST	90732	15	012B189   522	7563007016	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	33.72525	-118.32016	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71649	16041-20001-05916	5161 N DUMONT PL	91364	3	171B109   238	2166016008	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.16302	-118.58002	Expedite per applicant request. {{{{{{Plan check for PV roof mounted system. System size: 10.3kW with 48 modules and 48 microinverters connected to load center.}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71650	17041-10000-32959	10250 W SANTA MONICA BLVD #1365	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for power and energy for fisrt time tenant ""Breitling"" Ste # 1365 in Westfield Century City."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71651	15041-10000-03694	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	04/24/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Plan Check for power and energy for new restaurant. Total area = 1604 sq. ft. 2 New panels, exisiting service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71652	19041-20000-03021	4529 N SHERMAN OAKS AVE	91403	5	168B145  1010	2283017006	C1-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.15316	-118.46943	Plan check for new fire alarm system for office space. Total fire alarm devices: 9 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71653	16041-10000-42002	13931 N BALBOA BLVD	91342	7	228B137   228	2603025026	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Closed	03/14/2018 12:00:00 AM	ADDRESS	34.32381	-118.49103	T-24, PC FOR ENERGY ONLY. TITLE 24 NEW LIGHTING AND RECEPTACLES FOR A COMMERCIAL SPACE. TOTAL AFFECTED AREA IS  9220 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71654	18041-10000-37950	20701 W SESNON BLVD	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM			PC Approved	11/08/2018 12:00:00 AM	ADDRESS	34.29478	-118.58219	INSTALL LIGHTS IN PRIVATE ROADS FOR TRACK HOMES. EFFECTED AREA 401,522 SQR FT.PLAN CHECK FOR T-24 ENERGY ONLY. <<<FEE ESTIMATE ONLY>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71655	15041-10001-13263	15927 W VENTURA BLVD	91436	5	168B141   544	2261021007	C4-1L, P-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.15615	-118.48017	CHANGE TO APPRVOED SET OF PLANS. RECHECKING FOR FULL PLAN CHECK DUE TO ASSEMLBY OCCUPANCY. CHECKING IN ACCORDANCE TO LAEC SECTION 93.206. TITLE T24 APPROVED UNDER MASTER APPLICATION. THIS APPLICATION IS FOR FULL PLAN CHECK FOR 2 NEW PANEL BOARDS AND HVAC UNIT ON ROOF. CHECKING CIRCUITRY TO LIGHTING. PER APPLICANT NO CHANGE TO KITCHEN EQUIPMENT. INSPECTOR TO FIELD VERIFY NO OTHER MODS AS NOTED ON PLANS.SCOPE UNDER DELTA-2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71656	14041-10000-34504	2751 S ALAMEDA ST	90058	9	117A215    60	5117017015	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.01306	-118.24059	T24, REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 28892 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71657	14041-20001-23259	1233 N VERMONT AVE	90029	13	144B197   110	5540017004	C2-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			08/26/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.09432	-118.29195	Expedited plan check per applicant. (((PV2.  Install 14.84 kW utility-interactive PV system on apartment building rooftop.  3ph 120V/208Y transformerless inverter.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71658	19041-10000-50774	2581 E CHAUCER ST BUILDING 2	90065	1	145-5A217 517	5445031***	[Q]CM-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	09/03/2020 12:00:00 AM		Permit Finaled	11/22/2021 12:00:00 AM	PIN	34.0949861	-118.23281575	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A SERVICE OF 800A, 120/208 V, 3-PHASE 4W FOR BUILDING 2. TOTAL AFFECTED AREA: 8246 SQ FT 5 BUILDINGS ARE CONNECTED TO 1 SERVICE SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71659	11041-10000-24063	7617 W SUNSET BLVD	90027	4	147B177   942	5550006028	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	11/09/2011 12:00:00 AM		Permit Finaled	01/20/2012 12:00:00 AM	PIN	34.09835673	-118.35560071	New 600A service and 600A switchboard and new feeders to supply exist. panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71660	17041-20000-16275	10073 N ORCAS AVE	91040	7	204B173   283	2542009015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	09/07/2018 12:00:00 AM	ADDRESS	34.25387	-118.36863	Plan check for a PV1 ground-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (30) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71661	16041-30000-15421	801 S FIGUEROA ST	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM			PC Approved	05/03/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	Plan check for Title 24 only. Project site is the corridor on the 17th floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 1,580 sq. ft.Note: Building application has been created under 16016-10000-09255	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71662	17041-10001-31320	8500 W BEVERLY BLVD 113	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Issued	02/05/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE REVISING LIGHTING FLOOR PLANS, ADDING RELOCATING RECEPTACLES ON THE POWER FLOOR PLANS, AND REVISING TITLE 24 CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71663	10041-10000-16654	619 S OCEAN FRONT WALK	90291	11	109-5A143 575	4286028019	C1-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM			PC Approved	08/24/2010 12:00:00 AM	ADDRESS	33.99203	-118.47804	INSTALL NEW DEVICES TO EXISTING FIRE ALARM SYS. Plan check for power. (Permit was pulled # 09041-10000-20018)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71664	17041-20000-23173	5554 N CAHUENGA BLVD	91601	2	174B177   680	2417001041	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.17157	-118.36138	PLANCHECK FOR T24 ENERGY. ADDITION OF LUNCH/BATHROOM ON THE 1ST FLOR ,  NEW 2ND FLOOR OFFICE  TO (E) DAY CARE CENTER. 2939 SQFT.BUILDING PERMIT # 16014-20000-00927	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71665	13041-10000-07523	11427 S AVALON BLVD	90061	15	087A207   367	6083006015	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM			PC Approved	04/05/2013 12:00:00 AM	ADDRESS	33.93019	-118.2654	PLAN CHECK FOR ENERGY ONLY T24 FOR MULTIPURPOSE BUILDING (ACCESSORY TO ALLIANCE PUBLIC SCHOOL). 1606 SQRFT INDOOR. 4000 SQRFT OUTDOOR. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71666	17041-20001-23794	18165 W ECCLES ST	91325	12	192B125   355	2786025022	RS-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM			PC Approved	07/25/2017 12:00:00 AM	ADDRESS	34.2239	-118.52975	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71667	13041-10001-28804	6904 N VANTAGE AVE #106	91605	2	183B165   722	2321010***	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.19578	-118.39751	][][ EXPEDITED PER APPLICANT REQUEST ][][]PV1, ROOF-MOUNTED SOLAR INSTALLATION IN A 2-STORY HOUSE. INTERCONNECTING WITH (E) 200A MAIN SERVICE. SYSTEM SIZE IS 5KW DC, & IS XFORMERLESS, WITH (20) MODULES: TRINA SOLAR #TSM-250PA05.18(1)POWER-ONE #AURORA PVI-4.2-OUTD-S-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71668	18041-10000-01600	6801 W HOLLYWOOD BLVD #B2-243	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM			PC Approved	01/16/2018 12:00:00 AM	ADDRESS	34.10229	-118.33907	Plan check for title 24 only in existing space. Totla area: 730 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71669	13041-10000-19899												Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM			PC Approved	07/19/2013 12:00:00 AM					N	N	Express Permit	06/10/2024 12:00:00 AM
71670	15041-20000-01570	736 S CROCKER ST	90021	14	126A213   437	5146032037	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.03912	-118.24671	THIS PERMIT IS PART OF 3 UNITS. THIS IS FOR PERMIT 736 CROCKER, THIS PERMIT ALSO INCLUDES HOUSE PANEL AND MAIN 600A SERVICE. OTHER UNITS UNDER SEPARATE PERMITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71671	19041-10000-46397	8804 N NOBLE AVE	91343	6	195B145   389	2653008034	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.23027	-118.46097	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 22 AC MODULES (SUNPOWER SPR-A400-G-AC).  SYSTEM SIZE IS 8.8KWdc and 7.68KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71672	19041-10001-19612	2500 W 7TH ST	90057	1	133-5A201 278	5141014001	C2-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM			PC Approved	08/26/2019 12:00:00 AM	ADDRESS	34.0583	-118.28122	Change to approved set by reconnecting one panel to an existing meter. All changes under delta-5 only.(((Full pc (pwr and energy) for commercial tenant spaces 2 story building. Existing service 800A, 120/240V, 1ph, 3w will existing and new loads. area of scope is 21,000sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71673	16041-20001-44802	10532 W BURBANK BLVD	91601	2	174B177   587	2417001009	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Approved	04/27/2017 12:00:00 AM	ADDRESS	34.17201	-118.36066	04/14/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 4,080 sq. ft.Note: Buiding permit has been issued under 16016-10000-13420. Additional electrical permit fees have been paid under 17041-20000-11568.*****Previous Work Description*****INSTALL (N) 100AMP SUB-PANEL; (90) OUTLETS AND SWITCHES FROM (N) SWITCHES. (NO LIGHTING)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71674	16041-20000-22634	840 W 34TH ST	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	PIN	34.02192429	-118.28551249	Plan check for energy.  Changes to lighting system/electrical in (E) theater/performance space.  1320 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71675	16041-10000-17114	10024 SILVERTON AVE	91042	7	202-5A201 137	2568004003	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM	05/16/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	PIN	34.25068091	-118.28437446	PV1roof mounted installation to a single family dwelling. Inverter rating: 3.0 kWac , and (9) modules with optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71676	18041-20000-20179	6908 N QUAKERTOWN AVE	91306	3	183B113   656	2135027021	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM	05/31/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.19595	-118.56975	Plan check for a PV1 roof-mounted PV system. System size is 10.4KVA consisting of (2) inverter - solivia 5.2TL, (30) modules, and (1) load centers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71677	12041-10000-31186	1460 W FRANCISCO ST	90501	15	057B193   129	7351037019	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	33.85006	-118.30117	PREVIUOS WAREHOUSE BUILDING WITH TENANT IMPROVEMENT. UPGRADING SERVICE TO 2000A. ADDING NEW PANELS AND BRANCH CIRCUITS. ALSO T24 FOR LIGHTS LOCATED IN COOLERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71678	12041-10000-18352	6800 N VAN NUYS BLVD	91405	6	183B149   754	2217009033	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			08/06/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.19428	-118.44846	Plan check for new roof mounted 17.64KW photovoltaic system. Existing Wells Fargo Bank.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71679	16041-20000-39509	225 N VERMONT AVE	90004	13	138B197   512	5518033032	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.02	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM			PC Approved	11/08/2016 12:00:00 AM	ADDRESS	34.07529	-118.29188	Plan check for energy only. TI to existing retail space - divide into 3 separate retail spaces and add restrooms. New lighting (incl. emergency). 3,785sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71680	11041-10000-12454	400 S HOPE ST 11th and-20th flr	90071	9	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM	06/16/2011 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.05199	-118.25366	T.I. for the 11th and 20th floor.  Replacing light fixtures.  Plan check is for energy and emergency only,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71681	13041-10000-35273	726 E 12TH ST # 106	90021	14	123A211    22	5132012060	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	12/18/2013 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.03314	-118.25248	Plan check for T24 only. Changing  fixtures with existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71682	19041-10000-31141	17512 W CALIFA ST	91316	5	177B129   783	2254027022	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.17813	-118.51464	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 7.6KVA PV1 SYSTEM WITH ESS CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 20 MODULES USING P400 OPTIMIZERS AND TESLA POWERWALL. MAIN BREAKER DERATING SHALL BE PULLED UNDER DIFFERENT PERMIT   Install 7.2 KW (DC) 6.4 KW (AC) PV system20 - Panels1 - Inverter1 - Tesla Powerwall20 - Optimizers (P400)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71683	14041-20000-03933	739 S OGDEN DR 1-45	90036	4	132B177    82	5086010018	R3-1	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			02/12/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	ADDRESS	34.06151	-118.36021	45 units apartment	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71684	13041-10000-12093	12304 W SANTA MONICA BLVD	90025	11	126B145   865	4267031001	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Commercial			05/09/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.03925	-118.46584	PV2 ROOFMOUNT on 3 STORy building. NONSTandarD plan.  64kw ballasted system. 248 modules @ 260 W (Talesun tp660M-260W).  XFMR inverter solectria (model 60kw) .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71685	13041-10001-14606	217 E 8TH ST	90014	14	127-5A211 327	5145003005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/18/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Closed	09/21/2015 12:00:00 AM	ADDRESS	34.04155	-118.25168	CHANGES TO PERMITTED SET OF PLANS. Plan check for power and energy. Contains Sheets 0.20,0.30/a/b/c,0.40a/b,0.60a/b,2.00/1/2/3/4/5/6. Most changes identified by clouds: Installing low level exit  signs (photoluminescent), added 2 retail meters and panels to RMDB, 2 elevators on legally required board were changed to 480V,  changed layout of ground/basement floor, updated load calculations and T24 calculations.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71686	14041-10000-27492	300 S SANTA FE AVE # Q	90013	14	127-5A217   3	5163017900	(T)(Q)C2-2D-RIO, PF-1XL-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/06/2014 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.04587	-118.23239	Plancheck for power and energy.  First time tenant resturant. Total area 1580 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71687	13041-10000-06121	380 WORLD WAY T56	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/08/2013 12:00:00 AM			PC Info Complete	07/05/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	NEW PINKBERRY FOR SMALL TENANT SPACE AT THE LAX AIRPORT. NEW TOM BRADLEY TERMINAL. FIRST TIME TENANT, PC FOR POWER AND ENERGY. SPACE T56	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71688	14041-10000-10785	8500 W BEVERLY BLVD suit # 765	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	Tenent improvement, title 24 and emergency lighting. this is on unit equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71689	19041-20000-01137	1950 S SAWTELLE BLVD	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.04129	-118.44377	Renovation to (E) commercial building first floor common area.  Outdoor lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71690	16041-20000-39872	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Closed	07/13/2021 12:00:00 AM	ADDRESS	34.03941	-118.25893	Temporary power for construction - separate service for manlift.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71691	16041-20000-21243	10356 W DIAMOND ST LOT 19	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71692	14041-20000-01702	6925 S KNOWLTON PL	90045	11	102B173   321	4103012006	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			01/21/2014 12:00:00 AM	04/06/2015 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	33.97414	-118.37142	New 15 unit apartment building.  New 1000Amp service.  Full Plan Check.  (Variance to separate fire alarm has been paid.)plan check in accordance to 2008 NEC per building submittal	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71693	10041-10000-19270	100 W WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM			PC Info Complete	12/13/2010 12:00:00 AM	PIN	33.94153561	-118.3984113	Replace elevator(s) and other electrical upgrade.   Plan checked at applicants request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71694	14041-20000-22199	15217 W KNAPP ST	91343	7	198B145   261	2656024014	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	09/04/2014 12:00:00 AM		Permit Expired	10/03/2016 12:00:00 AM	ADDRESS	34.2382	-118.46374	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6KW INTERCONNECTED WOTH MSP.(28) TRINA SOLAR TSM-255 MODULES(1) SOLAREDGE  SE6000(28) SOLAREDGE OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71695	14041-10000-29402	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			Verifications in Progress	12/04/2014 12:00:00 AM	ADDRESS	33.78054	-118.23195	At the Valero Refinery, temporary installation of  MV distribution system to power existing equipment during the replacement of the old distribution system. Non-hazardous installation	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71696	16041-20001-18452	8206 S HOOVER ST	90044	8	099B201  1287	6032022028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM			PC Approved	05/28/2016 12:00:00 AM	ADDRESS	33.96404	-118.28691	Expedite per applicant request{{{{{Plan check for PV roof mounted system. system size: 3.8kW with 13 modules and 1 inverter(3.8kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71697	14041-10000-07071	1240 S NAOMI AVE	90021	14	121-5A213  54	5130006900	PF-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	05/14/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.02783	-118.24431	1 of  2 systems. Change of engineer and contractor. Rooftop solar for BLDG A (warehouse).PV2 210.8KWdc. 480V. positive GND. NONstd. 1story. Roofmount. [(1) inverters: {Solectrica SGI-225}]. [(496)modules: {SUNPOWER {spr-320-WHT-D}}]     'Expedited plan check per applicant request'Plan checker to revise description.previous plan reference: 12041-10000-06288Plan check for 439.22KWdc roof and ground (canopy) mounted system.  The new 1600 A service, switchboard, and lighting plan check under #12041-10000-06291.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71698	19041-20000-02922	2720 S GREENFIELD AVE	90064	5	123B157   742	4256020043	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2019 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.0328	-118.42734	Installation of 13.5 kWh energy storage system and 200A subpanel.  System addition to (E) 13.5 kWh energy storage system and 9.8 kW PV system.Derating of main circuit breaker to 150A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71699	11041-20000-19538	14710 W SUTTON ST	91403	4	165A149    62	2276028021	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.04	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2011 12:00:00 AM			Verifications in Progress	11/02/2011 12:00:00 AM	ADDRESS	34.14778	-118.45456	Installfuel cell	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71700	13041-20000-27547	7425 S MAIN ST	90003	9	102B201  1362	6031007026	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	33.9719	-118.27421	PC FOR POWER AND ENERGY. NEW LAUNDRY MAT. NEW 800A SERVICE. TOTAL AREA 4943 SQ FT. OUTDOOR LIGHTING INCLUDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71701	13041-10000-33283	5985 W CENTURY BLVD	90045	11	093B169   304	4124030043	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	33.94572	-118.38869	PLAN CHECK FOR POWER AND ENERGY .  FROM BUILDING PERMIT: T.I. of restaurant & service areas , bars and lobby at 1st floor of hotel  : remove / replace non-bearing partition walls at restaurant , pizza & sushi bars ; remodel restrooms ; new store front and new wall & floor finishes ;  replace some ceiling tiles ; millwork .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71702	11041-10000-09923	2190 E 14TH ST	90021	14	120A217    76	5167016024	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Public Safety Only			05/16/2011 12:00:00 AM	05/16/2011 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	34.02344	-118.23347	INSTALL A NEW CENTRAL STATION FIRE ALARM PANEL IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71703	17041-10000-00345	15233 W LA CRUZ DR	90272	11	129B125   734	4412002016		West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	34.04577	-118.52516	PV, ADDITION OF 6.9 KW DC ROOF-MOUNTED PHOTOVOLTAIC SYSTEM ON A COMMERCIAL BUILDING, WITH (23)  MICROINVERTERS: ENPHASE S280 (23) MODULES:  CANADIAN SOLAR 240 W TO AN EXISTING SYSTEM WITH ENPHASE M215 MICROINVERTERS (11041-10000-19354)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71704	17041-30000-33483	633 W 5TH ST 8th Floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	01/25/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for Title 24 only in existing office space T.I. Total area: 3,110 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71705	18041-20001-38421	5242 W 104TH ST	90045	11	090B173   290	4129035013	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	33.94183	-118.37188	expeditepv2install roof mounted pv system sized 90KW AC interconnected with msp.NOTE:This building has (2) services, 1 phase and 3 phase.  pv system to interconnect both services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71706	18041-20001-27276	3986 N DRYSDALE AVE	90032	14	145-5A233 201	5307011003	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	Yes	2011.10	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM			PC Approved	09/14/2018 12:00:00 AM	ADDRESS	34.09228	-118.17519	09-14-2018 Changes to an approved set of plans, changes include  increase breaker in the main panel from 60A to 125A  breaker. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71707	15041-20000-11994	2151 S AVENUE OF THE STARS 1-375	90067	5	132B161   193	4315019006	R4-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	11/25/2015 12:00:00 AM	ADDRESS	34.05439	-118.41225	Title-24 plan check only.  Total area = 660 sq. ft.T.I. to spa area in existing hotel.  Replacing existing lighting with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71708	10041-20000-05181	3229 N GLENDALE BLVD	90039	13	154-5A207 136	5435014003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	04/27/2010 12:00:00 AM	ADDRESS	34.11858	-118.26075	PHOTO VOLTAIC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71709	19041-20000-07543	20845 W HAYNES ST	91306	3	180B109   379	2148024012	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	03/01/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.19036	-118.58795	PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM 3.9 KW DC/3.48 KW AC. SCOPE OF WORK INCLUDES (12) CANADIAN SOLAR CS1K-325MS PV MODULES AND ENPHASE IQ7PLUS-60-X-US 240VAC MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71710	15041-10000-13029	6171 W CENTURY BLVD 2ND  & 3RD-FLOORS	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/30/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	IN EXISTING ,EMPTY OFFICE SPACE ONC2ND AND 3RD FLOORS, INSTALLING SOME LUMINAIRES AND POWER IN THE CORRIDOS, AND ELEVATOR LOBBIES AND BUILT-OUT  FOR PROSPECTIVE TENANT.PLAN CHK IS FOR TITLE 24 AND 2  EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71711	16041-10001-03511	1245 W WILSHIRE BLVD # 300	90017	1	132A207   288	5143017040	CW	Central	Westlake	Downtown Los Angeles		2091.02	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Approved	05/18/2016 12:00:00 AM	ADDRESS	34.05373	-118.26606	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. CHANGE TO CONTROLS. USE OF LOW VOLTAGE CONTROLS IN LUIE OF LINE VOLTAGE. UTILIZING ROOM CONTROLLERS AND LOW VOLTAGE CONNECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71712	18041-10002-22630	11439 N ENCINO AVE	91344	12	213B129   333	2711022027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM			PC Approved	05/06/2019 12:00:00 AM	ADDRESS	34.27848	-118.51547	Change to tapproved set by updating the input of the of the inverter and removing the fuses.(((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 42.24KWdc / 50.0KWac.(128)MODULES-CANADIAN SOLAR CS6U-330M(1)INVERTER-SMA SUNNY TRIPOWER CORE1)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71713	19041-20002-07149	5536 N LINDLEY AVE 1-129	91316	5	174B125   454	2159005021	R3-1-RIO	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	Apartment			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.17161	-118.52708	10/10/19CHANGES TO APPROVED SET DELTA 2 ONLY.<<<<PV2.  Install 100.38 kW DC / 91.72 kW AC roof mounted grid tied PV system.  (275) modules with (3) 30 kW rated string inverters.$0 permit fee per State Senate Bill SB 1222 as amended by State Assembly Bill AB 1414.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71714	18041-10000-06943	15708 W CHATSWORTH ST	91344	12	207B141   433	2661002002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.26445	-118.4744	PV 1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (36) MODULES WITH OPTIMIZERS AND (1) 11.4 INVERTER. TOTAL SYSTEM SIZE IS 12.6KWDC / 11.4KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71715	17041-10000-45005	927-931 N SYCAMORE AVE	90038	4	144B181   718	5531015008	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	34.08796	-118.34291	PC FOR WAREHOUSE TI FOR POWER AND ENERGY. SPLITING EXISTING SPACE INTO TWO SPACES FOR FUTURE TENANTS. INSTALLING MINIMUM LIGHTING AND EXIT SIGNS REQUIRED PER BUILDING CODE.SCOPE INCLUDES NEW 300KVA TRANSFORMER AND 2 NEW ( ONE OF THE PANEL RATED AT 600A) CIRCUITS AND LIGHTS TOTAL AFFECTED AREA 10078 SQ.FT.B# 17016-10000-33238	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71716	17041-10001-22607	10250 W SANTA MONICA BLVD # 2890	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Approved	08/24/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1st revision to approved set for Francesca's Ste. 2890. Changes noted under Delta 4&5. This scope is to remove all fixture with tag ID ""B"" and replace it with fixture tag ID A and A1. Load calculation and T24 are revised accordingly. This is plan check only, no supplemental permit is needed."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71717	16041-10000-31398	348 N CITRUS AVE	90036	5	138B185    38	5524038004	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.07772	-118.33956	PV1 ROOF MOUNTED PV SYSTM WITH 6KW INVERTER AND 30 MODULES IN TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71718	10041-20000-01619	8875 N TAMPA AVE	91324	12	195B117    48	2783025082	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch			1133.01, 1134.01	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.23184	-118.55382	PLAN CHECK POWER AND ENERGY FOR NEW BUIILDING AND NEW RESTAURANT WITH 1000 AMP SERVICE. VARIANCE FILED TO SEPARATE FIRE ALARM SYSTEM. SIGN LIGHTING WILL BE UNDER SEPERATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71719	12041-20000-18128	2914 W 8TH ST	90005	1	132B197   497	5077023015	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			08/02/2012 12:00:00 AM	10/31/2012 12:00:00 AM		Permit Finaled	01/10/2014 12:00:00 AM	ADDRESS	34.05751	-118.28966	New fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71720	17041-10001-13487	10250 W SANTA MONICA BLVD FC22	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM			Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	ADDED 36KVA 120/208V NON-INSTANT WATER HEATER AND 3EA 4.5KVA 208V OVENS; TRANSFORMER CHANGED FROM 45 KVA TO 75KVA FOR THE NEW KITCHEN LOADS REVISED SINGLE LINE TO INCORPORATE THESE CHANGES.(((((((((((Tenant Improvement at Wexler's Deli Century City Mall #FC22. Service and Dist.board all existing.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71721	19041-20002-23545	11847 W TERRA VISTA WAY	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM			PC Approved	09/25/2019 12:00:00 AM	ADDRESS	34.28595	-118.38982	Plan check only for underground wiring for site lighting per inspector correction notice.  Scope of plan check does not extend to service equipment or any other non-lighting circuits supplied by service.  (((Plan check for Title 24 only outdoor site lighting in 39 Single Family. Total outdoor area: 58,967 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71722	13041-10006-11192	1411 N HIGHLAND AVE	90028	4	147A185   220	5548015033	(T)(Q)RAS4-1-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	34.09649	-118.33888	REVISION TO THE APPROVED SET OF PLANS. DELETING 3 GFCI RECEPTACLES IN BAR ROOM,  UNDER DELTA 33   ((((REVISIONS TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 17 AND DELTA 20. REVISIONS INCLUDE CHANGES TO THE LIGHTING FIXTURES AND ENERGY CALCS.  ENERGY FALLS UNDER 2008 STANDARDS. PLAN CHECK FOR ENERGY ONLY. TOTAL SQUARE FFOTAGE 79358.  ((PROPOSE TO CONSTRUCT A MIXED USE PROJECT 76 UNITS (APARTMENT) & RETAIL ON THE GROUND FLOOR;  2,500 S.F. W/ SUBTERRANEAN GARAGE;  6 STORIES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71723	19041-10000-35739	3000 S ROBERTSON BLVD 150	90034	10	123B169   906	4311033015	C4-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.03242	-118.39001	ENERGY PC FOR T.I. TO EXISTING OFFICE INCLUDING NEW PARTITIONS, CEILING, AND FINISHES. AREA OF SCOPE 2,602 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71724	15041-10000-37221	300 S GRAND AVE	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	PIN	34.05243427	-118.25124731	TITLE 24 PLAN CHK FOR SIGNS USING LED LAMPS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71725	13041-20001-31266	10526 W DUBNOFF WAY BLDG A	91606	2	180B177   270	2412019023	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.03	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.18656	-118.36106	Modifications to approved set.  Change of location for distribution equipment around and interior to Building A.  (((PC FOR POWER. NEW 1600A SERVICE AND DISTRIBUTION. BUILDING A OF SERIESS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71726	10041-20001-04842	13164 W BURBANK BLVD	91401	4	174B157   656	2345005022	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			05/27/2010 12:00:00 AM			Not Ready to Issue	08/27/2010 12:00:00 AM	ADDRESS	34.17196	-118.4201	Plan check Delta 5 only changes on fluorescent fixtures to LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71727	13041-20000-20613	5100 N WOODMAN AVE 1-36	91423	4	171B157   802	2359024029	R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			08/02/2013 12:00:00 AM	02/07/2014 12:00:00 AM		Permit Finaled	11/13/2014 12:00:00 AM	ADDRESS	34.16311	-118.43103	NEW CONSTRUCTION OF 36 UNIT APARTMENT. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71728	13041-10000-30271	2903 W PICO BLVD	90006	10	129B193  1273	5080027012	[Q]C2-2	Central	Wilshire	Olympic Park		2132.02	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.04736	-118.30334	PV2, ROOF-MOUNTED PHOTOVOLTAIC SYSTEM INSTALLATION INTERCONNECTING WITH 225A MAIN BUS. SYSTEM SIZE 16.5 KW DC, WITH (66) MODULES (HANWHA HSL60P6-PB-4-250QB) WITH (2) TRANSFORMERED INVERTERS (SUNNYBOY; SB7000-US).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71729	17041-10000-10686	13172 W TERRA BELLA ST	91331	7	204B157   475	2623003008	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.25701	-118.41988	PC FOR PV SYSTEM ROOF MOUNTED. 10 MODULES AND 3.8KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71730	14041-20000-19850	22207 W KITTRIDGE ST	91303	3	180B101   240	2139015029	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.19137	-118.6104	3.5KW PV1 roof-mounted system with (14) Sun Edison SE-F270CzC-3y and Enphase M250 microinverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71731	10041-20000-14660	10969 W VENTURA BLVD	91604	4	162B173   432	2366022022	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.01	Electrical	Electrical	Commercial			07/28/2010 12:00:00 AM	07/28/2010 12:00:00 AM		Permit Finaled	09/08/2010 12:00:00 AM	ADDRESS	34.14069	-118.3694	PLAN CHECK T-24 ENERGY LIGHTING FOR T. I. & CHG OF USE FROM OFFICE TO VOCATIONAL CLASSROOMS. ALL CIRCUITS ARE EXISTING. PERMIT FOR UNITS AND LOW VOLTAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71732	16041-10000-45158	8505 S WESTERN AVE	90047	8	097-5A193 263	6035032039	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	03/02/2017 12:00:00 AM	ADDRESS	33.96069	-118.30921	COMPLETE PC FOR CHARTER SHCOOL. CHANGE OF OCCUPANCY FROM GROCERY STORE.New connected load less than 400A. Plan check due to occp. loadTotal affected area 11299 sq. ft was paid under submital 1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71733	11041-10000-23728	3601 S CRENSHAW BLVD	90016	10	120B185  1155	5046001040	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			11/04/2011 12:00:00 AM			PC Approved	11/22/2011 12:00:00 AM	ADDRESS	34.02383	-118.33529	T.I. to an existing retail space.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71734	15041-10000-21893	650 N MAIN ST	90012	14	133-5A215 296	5408011907	C4-1VL	Central	Central City	Historic Cultural		2071.00	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	PIN	34.05809191	-118.23765405	Energy plan check for TI. Main scope includes new lighting and receptacles. Total area is 5567-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71735	15041-10000-07330	601 S ANDERSON ST	90023	14	126A219    63	5171012001	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	34.03899	-118.22427	TI to (E) 14,785 sq. ft. warehouse space and single story building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71736	13041-20000-11839	445 S FIGUEROA ST 3750	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			05/07/2013 12:00:00 AM			PC Approved	05/07/2013 12:00:00 AM	ADDRESS	34.05295	-118.25675	T24 FOR EXISTING HIGHRISE OFFICE SPACE. 4940 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71737	10041-20000-09731	8110 N LANKERSHIM BLVD	91605	6	189B169    62	2311005040	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM			PC Approved	05/24/2010 12:00:00 AM	PIN	34.21795078	-118.38731326	Energyexisting permit 1004102001-07494	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71738	15041-20001-37501	13090 N BORDEN AVE	91342	7	222B153    25	2504016046	RA-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM			Reviewed by Supervisor	11/17/2015 12:00:00 AM	ADDRESS	34.30817	-118.44386	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (76) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71739	18041-20000-12011	9336 W WAYSIDE DR	91040	7	207B185   522	2549017009	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.26102	-118.33471	Plan check for a PV1 roof-mounted PV system. System size is 11.4 kWac and consists of (1) inverter and (35) modules. System is interconnecting with a 400-amp service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71740	18041-20000-46888	13268 W SEVILLANA WAY	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) micro-inverters and (7) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71741	10041-10000-16031	16207 W PARTHENIA ST	91343	12	195B141   709	2688015016	[T][Q]C2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.22855	-118.48554	New 7-11 store. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71742	16041-10001-14569	1616 W 209TH ST #2	90501	15	054B193   545	7349002009	RD1.5-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	33.84074	-118.3073	07/15/16CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REPLACING THE 125 SUBPANEL TO AN 200A SUBPANEL, ADDING A 20A FUSE FOR THE 30A DISCONNECT, AND REPLACING THE 100A MAIN SUBPANEL WITH A 400A 4 BANK METER. NOTE: PERMIT PAID UNDER PCIS#16041-10000-14569((((PV1 INSTALL 1.53 KW DC ROOF-MOUNTED SOLAR ARRAY ON A MULTI-FAMILY HOUSE.(6) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PVI-3.0-OUTD-S-US-Z-A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71743	12041-10001-16991	3939 S CRENSHAW BLVD	90008	10	117B185  1015	5032002058	C2-2D, [T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			10/31/2012 12:00:00 AM			PC Approved	10/31/2012 12:00:00 AM	ADDRESS	34.01358	-118.33646	ADDITION OF AN OUTDOOR LIGHTING. CHANGES ARE SHOWN WITH DELTA4. ((((((((((((PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR CHANGE OF USE FROM RETAIL TO RESTAURANT. LESS THAN 100 OCCUPANTS. LESS THAN 400A. CHIPOTLE))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71744	16041-10000-45771	380 WORLD WAY MSC-PAX	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	07/26/2021 12:00:00 AM	ADDRESS	33.94373	-118.40888	Full Plan check. Adding new lighitng, power, and emergeny power to LAX MSC PAX tunnel (Scope includes anything under 'TPX' labels on single line). Total area: 54000. b#16014-10000-02498	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71745	18041-20000-25655	20712 W BEECH CIR #295	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.29266	-118.58473	PV1.  Install 3.02 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71746	12041-20000-00150	8378 W MELROSE AVE #103	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			01/04/2012 12:00:00 AM			PC Approved	01/04/2012 12:00:00 AM	ADDRESS	34.08341	-118.37285	PLAN CHECK T24 ENERGY TENANT IMPROVEMENT ON EXISTING SPACE #103	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71747	16041-10000-10285	350 S GRAND AVE #2A	90013	14	130-5A211 204	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	PIN	34.05171748	-118.2505467	T-24, PC FOR ENERGY ONLY. CHANGE OF USE  FROM RETAIL TO YOGA STUDIO.  TI TO AN EXISTING   PORTION OF A COMMERCIAL BUILDING  AT PLAZA LEVEL  SUITE  2A. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3263 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71748	10041-10000-25858	820 S OLIVE ST	90014	14	127-5A209  83	5144018028	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM			Corrections Issued	02/25/2011 12:00:00 AM	ADDRESS	34.04452	-118.25719	NEW 20 STORIES MIXED USE BUILDING. 8 STORIES OF RETAIL/COMMERCIAL PLUS 12 STORIES OF RESIDENTIAL (78 UNITS) ABOVE.   FIRE LIFE SAFETY SUBMITTED UNDER PCIS # 10041-10000-25860.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71749	15041-20000-16267	936 S OLIVE ST UNIT 355	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #3 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71750	16041-10000-24536	6619 S BROADWAY	90003	9	102B201   103	6012005036	C2-1VL	South Los Angeles	South Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Commercial			07/13/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Expired	08/21/2018 12:00:00 AM	ADDRESS	33.97932	-118.27849	PV2. NEW SOLAR SYSTEM ON AN EXISTING TRIPLEX BUILDING. TOTAL SYSTEM SIZE IS 3.0KWac.(14)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-AB# PVI-3.0-OUTD-S-US-Z-A	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71751	12041-10000-04902	500 S VIRGIL AVE suite#105	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/05/2012 12:00:00 AM			PC Approved	03/05/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Ti in a coffee shop. EPC is for T24, Energy & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71752	11041-10000-09196	4374 S FIGUEROA ST	90037	9	112-5A201  56	5019029027	C2-1VL	South Los Angeles	Southeast Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM			Corrections Issued	06/07/2011 12:00:00 AM	ADDRESS	34.00396	-118.28246	BRAND NEW MULTI-TENANT RETAIL BUILDING, CORE AND SHELL AND CORE ONLY.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71753	12041-10000-14142	611 S WESTERN AVE	90005	10	135B193   910	5503031006	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.04	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM	09/24/2013 12:00:00 AM		Issued	09/24/2013 12:00:00 AM	ADDRESS	34.06305	-118.30927	upgrade service to 800A;  5 EA PANELBOARDS REPLACED  BECAUSE OF THE NEW ISC VALUE AND LOADS REMAINED THE SAME	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71754	10041-20001-11316	10960 W WILSHIRE BLVD 5TH FLR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM			PC Approved	12/27/2010 12:00:00 AM	ADDRESS	34.058	-118.44597	REVISION TO APPROVED PLANS. DELTA 3 REVISION TO EMERGENCY LIGHTING LAYOUT ON 5TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71755	16041-20000-41009	10247 ANGEL LANE	91331	7	204B165   433	2537004043	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25669223	-118.40454905	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71756	12041-20000-13823	24402 S SEAGROVE AVE	90744	15	039B209    96	7404034013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2012 12:00:00 AM	08/15/2012 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	ADDRESS	33.8045	-118.2578	Roof mounted P.V. system (4.7KW) with enphase microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71757	12041-20000-20249	22123 W VENTURA BLVD	91367	3	171B101    48	2169026066	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			08/27/2012 12:00:00 AM	09/19/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	PIN	34.16892004	-118.60890424	new 800A service upgrade for an existing vetinary office. Low-rise. new transformer and receptacle for mobile MRI unit. plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71758	19041-10000-02295	953 S ELDEN AVE	90006	1	132B197  1149	5076003032	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.05406	-118.28789	PLAN CHECK FOR ROOF MOUNTED 27.6KVA PV2 SYSTEM CONSISTING OF 3 CENTRAL INVERTERS (3)SE10000H-US. WITH 96 MODULES USING P400 OPTIMIZERS. Permit fees are $0 due to senate bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71759	14041-10001-14921	1624 W 7TH ST	90732	15	015B193   172	7559033015	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			Reviewed by Supervisor	06/20/2014 12:00:00 AM	ADDRESS	33.73837	-118.31278	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 7.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON ONE STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71760	17041-20001-10068	9171 N DE SOTO AVE BLDG B	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	07/25/2018 12:00:00 AM	ADDRESS	34.23778	-118.5888	07/25/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes were made to the lighting and power floor plans. The engineer of record has changed.*****Previous Work Description*****(N) 1 STORY TIRE SHOP.  Plan check for power and energy.  Building B.  Building A permit is being submitted concurrently on same set of plans.  Building permit filed under 17010-20000-00223.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71761	16041-10000-03263	6100 N WOODLEY AVE JAPANESE-GARDEN	91436	6	177B141     3	2251002903	OS-1XL-RIO, [Q]PF-1XL-RIO	South Valley	Encino - Tarzana	Encino, Lake Balboa		9800.24	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	34.18088	-118.48309	T-24, RENOVATION OF LIGHTING FIXTURES TO THE PATHWAY OF A JAPANESE GARDEN. NEW PANELS AND CIRCUITS. TOTAL SQ. FT. 9982.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71762	15041-20003-26271	22200 W SHERMAN WAY	91303	3	183B101   106	2024013189	C1-1VL-RIO, P-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.20073	-118.61062	"08-05-16 Changes to an approved set of plans. Changes include addition of AP-5 Panel and equipment changes in kitchen. Changes apply to delta ""D"" only{{{{{NEW RESTAURANT 800 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.}}}}}}"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71763	11041-10001-03748	1082 W 7TH ST first floo	90017	1	130-5A207 630	5143004011	CW	Central	Westlake	Downtown Los Angeles		2093.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/03/2011 12:00:00 AM	ADDRESS	34.05054	-118.2639	Ti in an office building. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71764	15041-10000-10792	12871 N SAN FERNANDO ROAD	91342	7	222B145   263	2604019004	C2-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	12/16/2015 12:00:00 AM	ADDRESS	34.30366	-118.46542	NEW FIRE ALARM SYSTEMS FOR 4 STORY, 18-UNIT APARTMENT. 62 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL AND 1 CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71765	14041-10001-06725	1407 S CABRILLO AVE	90291	11	108B145  1424	4238004018	RD1.5-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2014 12:00:00 AM			PC Approved	07/01/2014 12:00:00 AM	ADDRESS	33.99025	-118.46688	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOALR ARRAY ON A  2-STORY HOME. INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(14) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71766	09041-20005-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Approved	01/14/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	Modification to previously approved set of drawings for DELTA 212 Only.<<<<T. I. - new medical office bldg.(NEW HIGH RISE BUILDING, MEDICAL OFFICE, SHELL UNDER PCIS 08041-20000-22411)>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71767	18041-10000-26833	911 N SYCAMORE AVE	90038	4	144B181   761	5531015007	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			07/18/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.08755	-118.34291	PLAN CHECK FOR POWER AND ENERGY FOR TI (E) RESTAURANT, TOTAL OCC LOAD>100. TOTAL NEW CONNECTED LOAD APPROX. 400A CONNECTED TO EXISTING 600A SERVICE. TOTAL AFFECTED AREA 6650 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71768	12041-20000-11864	7635 N SAN FERNANDO ROAD	91505	2	186B177   561	2466036***	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			05/23/2012 12:00:00 AM	05/23/2012 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	34.20906	-118.35676	energy plan check office	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71769	14041-10000-02104	2049 S CENTURY PARK EAST 18TH FL	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 REVIEW FOR LUNCH ROOM IN OFFICE SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71770	16041-10000-39008	705 W 9TH ST 1-214	90017	14	129A207   334	5144021045		Central				2077.10	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.04607	-118.2616	PC FOR POWER. INSTALLATION OF 20 EV CHARGERS IN RESIDENTIAL AND COMMERCIAL TENNANTS. (E) SERVICE 3000A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71771	17041-20000-30663	9841 N AIRPORT BLVD 6th flr	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Issued	11/02/2017 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building( high rise).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71772	18041-10000-12350	3829 W 6TH ST	90020	10	135B193   857	5503021023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.06367	-118.30618	PC FOR T-24 ENERGY ONLY FOR A CHANGE OF USE FROM RETAIL STORE TO COFFEE SHOP. SCOPE INCLUDES NEW LIGHTING AND RECEPTICALS. TOTAL AFFECTED AREA IS 912 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71773	17041-30001-08987	11110 N RUFFNER AVE	91344	12	210B137   408	2682019001	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.27225	-118.49763	Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (40) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71774	19041-10000-34086	9505 S MAIN ST	90003	8	093A203    69	6053008001	CM-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	33.94998	-118.27405	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71775	13041-10000-13160	1431 E 110TH ST	90059	15	088-5A211 283	6070004900	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	ADDRESS	33.93592	-118.24921	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING. 5114 SQ FEET OF INDOOR AND OUTDOOR LIGHTING. SCOPE OF WORK < 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71776	17041-10000-36630	14149 W CANTLAY ST	91405	2	186B153   767	2217027013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.20244	-118.44181	PC for 37 new modules and optimizer with 11.4kW central inverter for SFD.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71777	13041-20000-29612	2601 W SAN FERNANDO ROAD	90065	1	150B213   379	5457007001	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			10/23/2013 12:00:00 AM			PC Approved	10/23/2013 12:00:00 AM	ADDRESS	34.10866	-118.24133	T24 FOR EXISTING ART STUDIO. TOTAL SQRFT 516	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71778	12041-20000-22757	1777 N WESTRIDGE ROAD	90049	11	135B137   357	4426006040	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2012 12:00:00 AM	10/29/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	34.06619	-118.49461	Plan check for PV. Single family dwelling. Roof mounted 23.76kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71779	19041-30000-09827	2049 S CENTURY PARK EAST Suite 2530	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is an existing commercial tenant space is a high-rise building. Project scope is a tenant improvement. Total lighting area = 5,182 sq. ft.Note: Building permit has been issued under 19016-10000-06099	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71780	11041-20000-14904	9221 N CORBIN AVE suite# 190	91324	12	198B117   166	2761001073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM			Corrections Issued	07/18/2011 12:00:00 AM	ADDRESS	34.23786	-118.56248	Ti in an existing office Bldg. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71781	17041-10000-06580	1640 S SEPULVEDA BLVD #210	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.04838	-118.44468	Plan check for Title 24 only in existing space T.I. in office area. Total area: 2,321 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71782	10041-10000-15173	116 N ROBERTSON BLVD # 801	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	08/04/2010 12:00:00 AM		Permit Finaled	08/31/2010 12:00:00 AM	ADDRESS	34.0758	-118.38356	REMODEL SPACE TO THAT OF AN OFFICEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71783	19041-10001-10685	5950 W JEFFERSON BLVD	90016	10	117B173   613	4204008014	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	05/03/2022 12:00:00 AM		Permit Finaled	09/28/2023 12:00:00 AM	ADDRESS	34.02115	-118.37745	REVISIONS TO APPROVED SET. CHANGES INCLUDE UPDATED ELEVATOR 1 AND 2 BREAKERS. REVISED LIGHTING LAYOUT AND REVISED POWER TO HVAC. ALL CHANGES ARE CLOUDED.***************************************************(((POWER AND ENERGY PLAN CHCK FOR A NEW MIXED USE, 4-STORY COMMERCIAL OFFICE & RETAIL BUILDING WITH 1 LEVEL OF SUBTERRANEAN PARKING. SCOPE INCLUDES NEW 2000A SERVICE. TOTAL AFFECTED AREA IS 120,294 SQ.FTB#19010-10000-01121)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71784	19041-10000-30939	740 S ALVARADO ST	90057	1	132A203   201	5141019007	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	04/01/2020 12:00:00 AM		Permit Finaled	09/01/2021 12:00:00 AM	ADDRESS	34.05522	-118.27735	FULL PC FOR POWER AND ENERGY FOR A FACTORY BUILT HOUSING OVER SITE BUILT FIRST FLOOR PODIUM. SCOPE INCLUDES NEW 1600A 120/208V 3 PHASE 4 WIRE SERVICE, AND NEW HOUSE PANELS. B#19010-10001-00848NOTE: DWELLING UNITS ARE STATE APPROVED AND NOT PART OF PLAN CHECK. PLEASE ASK FOR THE STATE APPROVED MODULE DOCUMENT BEFORE FINALIZING THE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71785	16041-10001-06550	2049 S CENTURY PARK EAST flrs 21-23	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	08/26/16Changes to an approved set of plans. All changes are made under delta F1. Changes include removing two lighting fixtures from lighting floor plan, relocating lighting fixtures, and revising emergency photometrics. Note: Permit is paid under PCIS#16041-10000-06550((((T-24, TI TO AN OFFICE ON PARTIAL 21ST, 22ND, AND 23RD FLOORS. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 16060.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71786	17041-10000-41090	17401 W ROSCOE BLVD	91325	12	192B129   270	2787019008	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.22125	-118.51208	REPLACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71787	17041-20003-19001	827 N VINE ST BLDG. B	90038	13	141B185    94	5533030031	[Q]C2-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.08598	-118.32689	Change of lighting control package from nLight to Lutron system.  Corresponding updates to lighting plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71788	12041-10000-21452	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			PC Approved	09/11/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	TENANT IMPROVEMENT IN SUITE#210 0FFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71789	16041-20000-28234	6801 W HOLLYWOOD BLVD Suite 167	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			08/09/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,368 sq. ft.Note: Building application has been generated under 16016-10000-18486	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71790	13041-10002-33845	1300 W 177TH ST BLDG E	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	33.87031	-118.29542	(2) SINGLE PHASE CONVERTERS ADDED TO AN APPROVED SET FOR CONNECTING TO (2)  EXISTING 3-PHASE AC EQUIIPMENT. TOTAL ADD-ON APPLY TO  DELTA 5 ONLY.(((PLAN CHECK FOR POWER AND ENERGY NEW BUILDING. 1 STORY. BUILDING E( MEETING BUILDING).  PANEL HPF CHARGED UNDER BUILDING F 13041-10000-33846. Provision for EV charger on either of the panels serving E or F. Outdoor lights for decoration only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71791	17041-20000-43716	3828 W TRACY ST	90027	4	150B201   888	5433020010	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.10623	-118.2761	PV1.  Install 6.6 kW roof mounted grid tied PV system.  (20) panels with 6 kW rated central inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71792	16041-20000-31824	2911 S HOBART BLVD	90018	8	120B193   104	5053009031	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM	ADDRESS	34.02869	-118.30795	Plan check for roof-mounted solar array on a SFD. Interconnect with a 200A MSP.3.8kW ungrounded system. One 300W power optimizer per pv module. (14) 300W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71793	10041-20000-08169	6136 N FULTON AVE 1-12	91401	2	177B157   502	2331027004	R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	05/21/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.18239	-118.42234	PV SYSTEM FOR COMMERCIAL BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71794	16041-20000-31814	3741 N ROYAL WOODS DR	91403	5	162B141   301	2280007020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.13893	-118.47247	Plan check for roof-mounted solar array on a SFD. Interconnect with 200A MSP. New 7.44kW ungrounded microinverter system (enphase 250)  w/(31) 285W pv modules. There is an existing 6.5kW pv system on the roof.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71795	10041-10000-00142	1550 S CALZONA ST	90023	14	117A227    73	5192002012	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM	01/05/2010 12:00:00 AM		Permit Finaled	03/18/2010 12:00:00 AM	ADDRESS	34.01438	-118.19633	New sprinkler monitoring system for an existing building.  The FACP is in 1550 Calzona St.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71796	18041-10000-10011	1159 E 11TH ST	90021	14	123A213   133	5132007042	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.03133	-118.24533	REPLACE INDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71797	14041-20000-29628	513 S WESTGATE AVE	90049	11	132B145   436	4404028015	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2014 12:00:00 AM	10/24/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.05482	-118.47156	PV1Install roof-top solar array on SFD. Interconnect with 200A MSP.System size: 4kW. Ungrounded system.19 250W pv modules across two strings (7+12).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71798	10041-20000-16672	13550 W SHERMAN WAY	91405	2	183B157    77	2328034024	C1-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.20103	-118.42834	fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71799	10041-20000-25651	2505 W 6TH ST	90057	1	133-5A203  29	5155029010	C2-2	Central	Westlake		YES	2088.02	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			Corrections Issued	02/13/2011 12:00:00 AM	ADDRESS	34.06164	-118.27923	Plan check for new roof mounted 14.17KW Photovoltaic System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71800	14041-20000-22230	1111 W WILSHIRE BLVD 104	90017	1	130-5A207  44	5143023020	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	08/15/2014 12:00:00 AM	ADDRESS	34.05259	-118.26348	Change of use from Retail to Ice Cream shop.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71801	14041-10000-11749	1123 S WALL ST	90015	14	124-5A209  96	5145023030	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.036	-118.25475	T24, Remove HID light fixtures and replace with new florescent fixtures.  Total area 576 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71802	19041-20000-20055	4916 N ENCINO AVE pv1	91316	5	168B129   151	2290004027	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.15981	-118.51402	permit fee $0.00 by state senate bill no. 1222pv1install roof mounted pv system sized 12.285KW AC interconnecte dwith msp.(2) tesla powerwalls ESS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71803	12041-10000-05931	1630 N NORTH MAIN ST	90012	1	136-5A219 638	5409013913	PF-1XL	Central	Central City North			2060.10	Electrical	Electrical	Commercial			03/15/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Expired	08/13/2014 12:00:00 AM	ADDRESS	34.06682	-118.22728	New outdoor lighting for a DWP 'Oil Depot'. in building #11  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71804	18041-20000-26588	21800 W OXNARD ST Suite 720	91367	3	177B105    81	2146006046	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 7,963 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71805	18041-10000-38346	10625 S SAN PEDRO ST	90003	8	090A205   306	6063026028	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	33.93948	-118.26967	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71806	16041-20001-25651	915 W WILSHIRE BLVD 7TH FLR	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/27/2017 12:00:00 AM			PC Approved	05/18/2017 12:00:00 AM	ADDRESS	34.05069	-118.2599	changes to an approved set of plans.  changes include lighting fixture types and energy recalculations.ths is plan check only.TI TO AN EXISTING COMMERCIAL BUILDING 7TH FLOOR ONLY.  ADDING NEW LIGHTING NE CONTROLS TO EXISTING PANELS.  PLAN CHECK OR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 6530.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71807	10041-10000-23814	1150 S OLIVE ST #2100	90015	9	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	01/04/2011 12:00:00 AM		Permit Finaled	04/18/2011 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI IN AN EXISTING OFFICES ON THE 21ST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71808	19041-20000-21413	5808 W SUNSET BLVD	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			06/05/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.09782	-118.31646	PLAN CHECK FOR TI TO 13TH FLOOR OF EXISTING HIGH RISE OFFICE. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1,950 SFB#19014-10000-02790	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71809	17041-10000-41271	7902 N ALLOTT AVE	91402	6	189B157   580	2301022016	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1197.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM			Reviewed by Supervisor	11/20/2017 12:00:00 AM	ADDRESS	34.21408	-118.4275	PC for PV solar with battery back up. Installing 35 modules with optimizers, two solaredge multimode inverters (15.2kW), one critical load panel, one load center, two LG batterys (11.8kW) abd two autotransformers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71810	08041-10001-05655	1500 E ANAHEIM ST	90744	15	030B213   115	7440001912	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.14	Electrical	Electrical	Commercial			05/22/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	33.78074	-118.24357	New building (ILWU LOCAL 13) with new electrical equipments.  New emergency generator and solar photovoltaic systems.  Plan check for power and energy.Note: Building permit submitted in 2007.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71811	19041-20000-49401	9560 N SUNLAND BLVD	91040	7	201B177   378	2544009014	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	10/26/2020 12:00:00 AM	ADDRESS	34.24523	-118.36321	fee cap per AB1414.PV1.  Install 20.0 kW DC roof mounted grid tied PV system.  (50) modules with (2) 7.6 kW rated inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71812	15041-10002-12642	456 N FAIRFAX AVE	90036	5	141B177  1234	5527030025	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			09/14/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	34.07979	-118.36128	DELTA 3 REVISIONS IN THE FIELD: INCREASE LIGHTING DENSITY; DISHWASHER #5 CHANGED TO 1PH, 2-POLE;REVISED TITLE 24 COMPLIANCE FORMS.PLAN CHK ONLY((((((((TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71813	15041-10000-35815	8825 S SEPULVEDA BLVD	90045	11	096B165   990	4122035027	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			10/26/2015 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	33.9565	-118.39648	PC FOR T24 FOR STARBUKS KIOSK  INSIDE RALPH STORE. TOTAL AREA 280 SQ. FT FOR STARBUCKS LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71814	15041-10000-10615	8483 W MELROSE PL	90069	5	141B173   428	5528001058	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.08373	-118.37606	ALTERATIONS IN RETAIL STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71815	17041-10000-23255	1055 S LA CIENEGA BLVD	90035	5	132B173   572	4332030021	C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	03/13/2019 12:00:00 AM	ADDRESS	34.05785	-118.37637	Title 24 plan check.  Replace HID fixtures with new LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71816	18041-20000-03467	15910 W VENTURA BLVD 8th Floor	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.15561	-118.47969	8th floor corridor TI remodel.  All new lights, all existing circuits, etc.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71817	11041-10000-13049	333 S GRAND AVE 31st floor	90071	9	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	06/23/2011 12:00:00 AM		Permit Expired	07/16/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	REPLACING NEARLY ALL THE LUMINAIRES ON THE 31st FLOOR OF AN OFFICE BUILDING; SWITCHES WILL REMAIN THE SAME; OCCUPANCY SENSORS ARE THROUGHOUT THE AREA.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71818	15041-10001-25712	20120 W VIA MEDICI	91326	12	219A115   350	2701041009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.29497	-118.57171	EXPEDITE PER CUSTOMER REQUEST (((PV 1 ROOF MOUNTED SOLAR SYSTEM FOR SINGLE FAMILY HOME. (2) INVERTERS 13.6KW INTERCONNECTED WITH THE MAIN SERVICE PANEL, (56) MODULES.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71819	17041-20000-40480	9841 N AIRPORT BLVD ste 512	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	33.94647	-118.38626	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71820	14041-20001-04034	6948 N TOBIAS AVE PV1	91405	6	183B149   439	2219024018	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	05/30/2014 12:00:00 AM	ADDRESS	34.19702	-118.45187	Changes from previously approved plans.  Change include one additional PV module.  No change in module and inverter type.  All changes are in DC side.   Note: Plan check/permit is $0.00 due to Senate Bill 1222 from 2012.*****Previous Description*****PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH MAIN SERVICE. TRANSFORMER SYSTEM, SIZED @ 6.240 kW DC. (2) INVERTERS, (24) REC 260W MODULES. NEW 200A MAIN PANEL, (1) 100A LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71821	13041-20000-09118	1950 E WASHINGTON BLVD	90058	14	118-5A215  29	5167005015	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	PIN	34.01879134	-118.23748008	clean energy propane station	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71822	13041-10000-35927	420 E 11TH ST #108	90015	14	124-5A209  72	5145023038	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/26/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.0365	-118.25443	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 560 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71823	19041-20001-22072	7590 N GLENOAKS BLVD 2nd Floor	91504	2	186B181    61	2401042012	(Q)C1.5-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.20894	-118.34376	07/17/2019 Changes to an approved set of plans. All changes have been clouded. Changes have been made to the lighting and power floor plans and have been reflected onto the Title 24 compliance forms.Note: Electrical permit fees have been paid under master application.*****Original Work Description*****Remodel of (E) 2nd story restrooms.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71824	17041-10000-23750	5749 S CRENSHAW BLVD	90043	8	108B185   837	5006004007	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	33.98935	-118.33115	T24 plan check to remove existing 18 fixtures and replace with new LED fixtures. total affected area 31075 sq. ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71825	16041-10000-36519	850 S HOPE ST roof ameni-ties	90017	14	129A209   239	5144020020	[Q]C4-4D	Central		Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Closed	08/15/2018 12:00:00 AM	ADDRESS	34.04528	-118.25988	Plan check for power and energy.  Buildout of rooftop amenity deck on 7-story lowrise parking garage which serves adjacent apartment building.  Place of assembly.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71826	12041-10000-19226	11922 W MCDONALD ST	90230	11	108B161   784	4218019007	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2012 12:00:00 AM			Reviewed by Supervisor	08/29/2012 12:00:00 AM	ADDRESS	33.98994	-118.40905	New rooftop, pv system for an existing sfr.  2.64kw system using DC/DC converters.  Misc. Permit is for DC/DC converters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71827	17041-20000-18990	13850 W DESMOND ST	91331	7	210B153   623	2616025012	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.27113	-118.43454	Plan check for roof-mounted solar pv system. Adding (7) EnPhase M250 microinverters [1.68kW ungrounded] and (7) 280W pv modules to existing 5.8kW ungrounded solar pv systempermitted under application #16041-90000-11506.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71828	14041-20000-12781	10270 W ALMAYO AVE	90064	5	129B161   275	4315014001	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			05/21/2013 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.04948	-118.41336	LOW VOLTAGE	N	N	Express Permit	06/10/2024 12:00:00 AM
71829	19041-20000-12712	6456 N PEACH AVE	91406	6	180B145   618	2234016005	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	04/25/2019 12:00:00 AM	ADDRESS	34.18834	-118.46741	PV1.  Install 6.29 kW roof mounted grid tied PV system.  (17) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71830	12041-10000-30779	"12746 W JEFFERSON BLVD ""4"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check power and energy for Building 4. Five story parking garage building with common subterranean parking to Building 1, 2, 3, and 4. Service supply from Building 3. Site located in methane zone. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71831	13041-10000-25811	12412 W VENTURA BLVD	91604	2	162B165   288	2369001021	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			09/18/2013 12:00:00 AM			PC Approved	09/18/2013 12:00:00 AM	ADDRESS	34.14268	-118.40345	PC FOR ENERGY ONLY.TI TO (E)  1 story DENTAL OFFICE  (Alexander Ash, DDS) PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71832	18041-30000-41858	10768 W BELLAGIO ROAD	90077	5	138B149     6	4362010023	A1-1XL-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.0802	-118.45043	Plan check for power only. Project site is an existing commercial building (golf course). Project scope is the installation of an above-ground fuel storage tank.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71833	17041-20001-10846	10900 N WILLOWBRAE AVE	91311	12	210B105   220	2722037001	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2017 12:00:00 AM			PC Approved	04/17/2017 12:00:00 AM	ADDRESS	34.26828	-118.59839	expeditepv1install roof mounted pv system sized 15.7kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71834	18041-10001-40718	17535 W DONMETZ ST	91344	12	210B129   112	2711007008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.27464	-118.51661	EXPEDITE FEE FOR <<<NEW 23.465 KW ROOF MOUNTED PV SYSTEM WITH 988 SOLAR PV MODULES ON A SINGLE FAMILY HOME AND 40.5KWH ENERGY STORAGE SYSTEM.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71835	13041-20000-04292	6600 N TOPANGA CANYON BLVD 49A	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM			PC Approved	03/13/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	Change to lighting in a commercial space.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71836	17041-10000-33064	777 S ALAMEDA ST # 126	90021	14	124-5A215  30	5146009007	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.03396	-118.24117	TI TO SUITE 126. GYM. A3 OCCUPANCY GREATER THAN 100. FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71837	17041-20000-16754	700 S FLOWER ST SUITE 820	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 4143 SQFT. SUITE 820	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71838	10041-20000-19114	1801 CENTURY PARK EAST #800	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			09/27/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	04/29/2011 12:00:00 AM	PIN	34.0621869	-118.41581732	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR OFFICE TI ON 8TH FLOOR. CIRCUITS ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71839	12041-20000-22431	4501 S FIGUEROA ST 1-21	90037	9	112-5A201 145	5018031026	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2321.20	Electrical	Electrical	Commercial			09/20/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	07/05/2013 12:00:00 AM	ADDRESS	34.00257	-118.28308	Plan check for fire alarm system. 1 new panel and 72 devices. MIJA Town Homes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71840	14041-10000-24355	4605 N LANKERSHIM BLVD #214	91602	2	168B173   921	2421028013	C2-2	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM			Verifications in Progress	06/05/2015 12:00:00 AM	ADDRESS	34.15405	-118.36832	Plan check for energy only. T24. No change in occupancy. Tenant improvement of offices. high rise. 2557 sq. ft. Emergency lighting. Suite #214, 2nd floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71841	16041-20001-28847	3307 N DERONDA DR	90068	4	157-5A191  11	5582024003	RE9-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2016 12:00:00 AM			PC Approved	08/23/2016 12:00:00 AM	ADDRESS	34.12776	-118.31952	RSES expedited plan check fee per applicant request.  PV1.  Install 10.79 kW roof mounted utility-interactive PV system.  (33) AC modules with (1) subpanel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71842	16041-30000-35985	601 S FIGUEROA ST 14th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.05076	-118.25881	Title 24 plan check.  T.I. to server room and storage area on 14th floor of existing commercial office highrise.  New lighting, receptacles, and HVAC.  Total area = 355 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71843	18041-10000-44577	5227 N WINDERMERE AVE	90041	14	163-5A221 150	5671019007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.14248	-118.21714	NEW ROOFTOP  6 KW AC PV SYSTEM FOR SFD, CONNECTED TO EXISTING 200A PANEL22 MODULES, 1 6KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71844	15041-20000-28366	17326 W BURMA ST	91316	5	174B133    74	2254024014	R1-1-RIO	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Expired	09/22/2017 12:00:00 AM	ADDRESS	34.17676	-118.51086	Plan Check for PV roof mounted system. System size: 5.0kW with 17 modules (SUNPREME GXB300) AND 1 inverter(5.0kW SMA  AMERICA SB5000TL-US) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71845	19041-20000-23261	20869 W LASSEN ST	91311	12	201B109    90	2741002005	C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.25013	-118.58824	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71846	17041-10001-34441	1600 N VIEWMONT DR	90069	4	148-5A173 411	5558017024	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM			PC Approved	11/03/2017 12:00:00 AM	ADDRESS	34.10018	-118.37913	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71847	19041-10000-42196	11270 W EXPOSITION BLVD	90064	5	123B153   303	4256011900	[Q]PF-1XL	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Commercial			10/17/2019 12:00:00 AM	10/17/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	34.03472	-118.43639	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71848	19041-10000-06194	832 W JAMES M. WOOD BLVD	90015	14	129A207   243	5138003015	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.04652	-118.26411	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71849	11041-10000-07236	8500 W BEVERLY BLVD # 746	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	08/11/2011 12:00:00 AM	ADDRESS	34.07587	-118.37754	(N) TENANT IMPROVEMENT OF AN (E) 2333 SF RETAIL SPACE WITHIN A COVERED HIGH RISE MALL; WORK TO INCLUDE (N) STOREFRONT, (N) INTERIOR FINISHES, (N) CEILING FIXTURES, (N) LIGHTING, (N) PLUMBING FIXTURES & (N) STORAGE RACKS; DEMO OF (N) NON STRUCTURAL <SEE COMMENTS> plan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71850	12041-10000-28324	11272 W MAGNOLIA BLVD	91601	4	171B173   667	2353003803	C4-1-CA, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.00	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.16475	-118.37695	INSTALL FUEL CELLS. 1200A MAIN BUS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71851	16041-20001-02260	13090 N BORDEN AVE	91342	7	222B153    25	2504016046	RA-1	North Valley	Sylmar	Sylmar		1064.03	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			Reviewed by Supervisor	02/03/2016 12:00:00 AM	ADDRESS	34.30817	-118.44386	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (76) modules, (2) combiner boxes, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71852	13041-10001-35859	11573 W SANTA MONICA BLVD	90025	11	126B149  1303	4261001029	C2-1VL, R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM			PC Approved	08/01/2014 12:00:00 AM	ADDRESS	34.045	-118.45378	(((8/1/2014- DELTA 2 CHANGES MADE TO APPROVED SET OF PLANS. REVISED LIGHTING ONLY. PLAN CHECK FOR T24 ONLY.)))First time tenant of a restaurant (Honey Boba) to a commercial building.  Install subpanel, branch circuits, and lighting.  Plan check for power and energy.Note: Core and Shell plans approved under 09041-10000-23338.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71853	11041-20000-09082	1080 S LA CIENEGA BLVD #307	90035	5	132B173   684	5087001029	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM			PC Info Complete	05/04/2011 12:00:00 AM	ADDRESS	34.05713	-118.37597	PLAN CHECK POWER AND ENERGY FOR CHANGE OF USE FROM OFFICE TO MEDICAL OFFICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71854	13041-10001-26137	24316 W BURBANK BLVD	91367	3	174B089   612	2047017009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.16975	-118.65499	][][][]EXPEDITED PER APPLICANT REQUEST][][]PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING TO MAIN PANEL IN A SINGLE-STORY HOUSE ON NON-STANDARD PLAN. NEW 100A PV LOAD CENTER WILL BE INSTALLED. SYSTEM SIZE 8.25KW DC. 2 TOTAL STRINGS, 1 STRING OF 16 MODULES. (33) MODULES: RENESOLA SOLAR MODULES - JC250M-24/BB(2) INVERTER: SOLAR EDGE  - SE3800A-US, SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71855	17041-20004-19660	11500 W CANTON DR	91604	2	159B169   378	2377016014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2018 12:00:00 AM			PC Approved	07/10/2018 12:00:00 AM	ADDRESS	34.13274	-118.38388	07-10-2018 Changes to an approved set of plan. Changes include revised drawing of main 200A main panel and relocated performance mete. All changes has been clouded.  Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71856	19041-10000-53701	12147 W MAGNOLIA BLVD	91607	2	171B165   487	2347019010	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Permit Finaled	02/08/2021 12:00:00 AM	ADDRESS	34.16501	-118.39813	PC FOR A FIRE ALARM SYSTEM. SCOPE OF WORK INCLUDES INSTALLATION OF 155 DEVICES AND 1 FILRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71857	18041-20001-32273	3070 W LOS FELIZ BLVD	90039	13	157-5A207 257	5435017019	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.12455	-118.26614	Revisions to approved set and additional equipment permit fees.  Approval for delta-1 revisions only.  Addition of BOH to scope of work and panels revised as (N) per field conditions.  (((Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from bakery/cafe to banquet hall. Work includes a total lighting area of 12,560 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71858	16041-20000-38511	12205 N HONDERO CT	91344	12	219B125   106	2601074013	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	12/08/2016 12:00:00 AM	ADDRESS	34.29526	-118.52723	Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (2) inverters, (66) modules, (1) load center, and (2) combiner boxes.Note: $0.00 permit fees due to Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71859	19041-30000-13347	2000 S AVENUE OF THE STARS Suite 1020	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	04/19/2019 12:00:00 AM	ADDRESS	34.05868	-118.41546	Plan check for Title 24 only. Project site is a suite on the 10th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 795 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71860	11041-10000-01629	468 S LA BREA AVE	90036	4	135B181   575	5507009014	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	02/08/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.06511	-118.34381	T.I. Lighting and Power. Title 24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71861	17041-20000-10880	1801-1811 N NEW HAMPSHIRE AVE	90027	4	150B197  1138	5589029025	R3-1	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Apartment			04/04/2017 12:00:00 AM	12/28/2017 12:00:00 AM		Issued	12/28/2017 12:00:00 AM	ADDRESS	34.10361	-118.29348	Plan check for power only. Project site is an existing apartment building. Project scope is a service upgrade to 600 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71862	16041-20000-38814	10202-10228 N GLENOAKS BLVD	91331	7	204B165   142	2528007015	[Q]C2-1VL, [T][Q]MR1-1VL	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.25586	-118.39365	Lighting and power for expanded site parking and reconfigured entrance/exit.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71863	14041-10000-06971	1134 S WESTWOOD BLVD	90024	5	132B153   225	4363022007	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.06011	-118.4448	TI for a restaurant. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71864	17041-20000-23935	21051 W SUPERIOR ST	91311	12	201B105   175	2746003003	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.24647	-118.59228	Install 22.8 kW solar PV system, roof-mounted on commercial building.22.8kW ungrounded system. (66) 345W pv modules.Each module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71865	14041-20000-00191	4900 S BELOIT AVE	90230	11	111B165   574	4215027016	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.01	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	33.99907	-118.4032	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.4 KW AC USING MICROINVERTERS STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71866	13041-10000-17898	26640 S WESTERN AVE STE C	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	33.78015	-118.30862	permit to be pulled at EPC counter only. PC for energy only. TI TO EXISTING VET. 1 story. less than 400A per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71867	14041-20000-19895	810 E PICO BLVD	90021	1	127-5A203  19	5135005010	CM-1	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.03119	-118.25079	Changes from previously approved plans (07041-20000-29915).  Changes include additional of subpanels, branch circuits.  Remove some subpanels and relocate some branch circuits.  All changes indicate by DELTA 2 and 3 as shown on plans.  Plan check for power.*****Previous Description*****NEW 4 STORY RETAIL WITH SUB. PARKING.   VARIANCE FILED TO SEPERATE FIRE ALARM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71868	13041-10000-34487	6250 N TOPANGA CANYON BLVD BLD # F	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	07/18/2014 12:00:00 AM		Issued	07/18/2014 12:00:00 AM	ADDRESS	34.18498	-118.60554	PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING F.BUILDING PERMIT # 13010-10000-02909.New  retail  bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71869	11041-10000-13114	12121 W WILSHIRE BLVD #   214	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	06/29/2011 12:00:00 AM		Permit Finaled	11/22/2011 12:00:00 AM	PIN	34.04391963	-118.46825257	Title 24 and emergency lighting, for 12 story building suite 214.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71870	14041-10000-18212	2700 W COLORADO BLVD # 104	90041	14	163-5A219 153	5682002026	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.14248	-118.22438	INTERIOR IMPROVEMENT OF (E) RESTAURANT.  NEW FINISHES, COUNTER, SOFFIT.  LTS.  KITCHEN EQUIPMENTS.  ELIMINATE SINGLE OCC. RESTROOM.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71871	13041-10000-35988	1800 CENTURY PARK EAST 15TH FLOOR	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	PIN	34.06270629	-118.4150769	PLAN CHECK FOR T24 ENERGY ONLY.  HIGH RISE. WORK ON 15TH FLOOR AND 2 CONFERENCE ROOMS ON THE 14TH FLOOR. OFFICES. NO CHANGE IN OCCUPANCY. 12,900 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71872	17041-20001-13151	6802 N ALDEA AVE	91406	6	183B133   968	2230002012	RA-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			04/21/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	34.19421	-118.50823	expeditepv1install rooof mounted pv system sized 19kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71873	19041-20000-41037	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71874	18041-20000-43043	11247 N BERTRAND AVE	91344	12	210B125    67	2715019038	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South	YES	1112.01	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	04/02/2019 12:00:00 AM	ADDRESS	34.27544	-118.52561	Plan check for a PV1 roof-mounted PV system. System size is 11.2 kWdc/10.45 kWac-CEC and consists of (1) 10 kWac-rated inverter and (35) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71875	12041-10000-05475	8511-8511 1/2 S VERMONT AVE	90044	8	097-5A199 225	6033026026	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			03/09/2012 12:00:00 AM			PC Approved	03/20/2012 12:00:00 AM	ADDRESS	33.96057	-118.292	T.I. to  existing retail spaces at 8511 & 8511 1/2  Change to lighting, receptacles, and loads.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71876	10041-20000-22410	5150 W WILSHIRE BLVD	90036	4	132B181    35	5507025021	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Public Safety Only			11/08/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	ADDRESS	34.06202	-118.3421	Plan check new fire alarm system for core & shell.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71877	15041-20000-15276	7950 W SUNSET BLVD SUITE 102	90046	4	147B177  1021	5554003055	(Q)RAS4-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM			Corrections Issued	05/19/2015 12:00:00 AM	ADDRESS	34.09777	-118.36322	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR A GYM. 2709 SQFT. SUITE 102	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71878	13041-20001-32815	1465 N ARMADALE AVE	90042	14	157-5A223  82	5474016033	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.12422	-118.2117	((Expedite Fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.5KW. 1 COMBINER 1 INVERTER AND 22 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71879	17041-20000-17094	1812 S ROXBURY DR	90035	5	129B165   711	4307013027	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Issued	06/08/2017 12:00:00 AM	ADDRESS	34.04821	-118.40115	Plan check for a PV1 roof-mounted PV system. System size is 19 kWac and consists of (55) AC PV modules and (1) load center.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71880	17041-10000-11205	3274 N NORTH KNOLL DR	90068	4	157-5A183  18	5579034035	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.12785	-118.34312	PC for 10.4KW rooftop PV system for single family. Total of 39 LGNEON_2 modules, 2 Delta Solivia 5.2KW central inverters, one 125 A load center.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71881	10041-10000-05201	738 S MARIPOSA AVE	90005	10	132B197   337	5094006005	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Apartment			03/23/2010 12:00:00 AM	04/05/2010 12:00:00 AM		Permit Finaled	05/03/2010 12:00:00 AM	ADDRESS	34.05864	-118.29858	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR AT&T MOBILE SITE IN EXISTING APT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71882	19041-20000-20163	9132 N DE GARMO AVE	91352	6	198B173   154	2408034047	M3-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.23512	-118.3746	1600A 480Y/277V 3ph-4w service upgrade for proposed CNG fueling and parking/storage.Scope of work consists of 1600A service and panelboard.CNG equipment under future separate permit.  (E) site load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71883	15041-10000-05552	15301 W VENTURA BLVD	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Issued	04/07/2015 12:00:00 AM	ADDRESS	34.15411	-118.46654	Plan check for Title-24 only for T.I. Wax Salon. Total area: 1828 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71884	12041-10002-20762	1520-1520 1/2 S WESTERN AVE	90732	15	012B193   434	7560013045	R2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2970.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2013 12:00:00 AM			Corrections Issued	05/24/2013 12:00:00 AM	ADDRESS	33.72974	-118.31291	Plan check for 11KW roof mounted photovoltaic system. 2-family dwelling(((((((((( 5-24-2013  CHANGES MADE TO PREVIOUSLY APPROVED SET ADDITION OF 2 SUB PANELS, ONE SERVICE UP GRADE AND ONE SERVICE PANEL.))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71885	11041-10000-03146	1150 S OLIVE ST 20TH FL	90015	9	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	04/28/2011 12:00:00 AM		Permit Finaled	06/30/2011 12:00:00 AM	ADDRESS	34.03962	-118.26181	ALTERATIONS IN OFFICESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71886	16041-10000-14827	3761 S HILL ST	90007	9	117A203    89	5122028006	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.01524	-118.27792	"FULL PLAN CHECK FOR A CHANGE OF USE TO OFFICE AND WAREHOUSE (TI FOR ENTIRE 2 STORY  BUILDING,). ALL EXISTING ""SERVICES"" AND (E) 5 SWITCHGEARS NEWLY CONNECTED LOAD OVER 400A. 33 NEW SUB PANELS TO TENANT SPACES, 12 TYPICAL.  TOTAL SQFT=57970."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71887	15041-20000-03609	3231 S LA CIENEGA BLVD Bldg 5.02B	90016	10	123B173  1684	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Closed	09/04/2015 12:00:00 AM	ADDRESS	34.02942	-118.37312	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR 1ST AND 2ND FLOOR. CREATIVE ADVERTISING OFFICES.BUILDING P# 14016-10000-19518   PROPOSED OPEN ATRIUM SECOND STORY ADDITION (1,100 SQ FT) AND CHANGE OF USE FROM MANUFACTURING TO FACILITIES FOR THE DEVELOPMENT AND/OR PRODUCTION AND MANUFACTURE OF COMPUTER AND MEDIA-REATED PRODUCTS AND SERVICES, INCLUDING HARDWARE. BUILDING FULLY SPRINKLERED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71888	14041-20000-00012	20437 W SCHOENBORN ST	91306	3	192B109   654	2781026002	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.2211	-118.57918	PV1 TRANSFORMERLESS SYSTEM. 4 STRINGS 1 INVERTER. TOTAL SYSTEM SIZE 6KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71889	14041-20000-04612	2806 N CLEARWATER ST	90039	13	150A211    36	5437028012	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.10729	-118.25317	Install new lighting in the kitchen area and the entry to the kitchen.  Plan check for energy only. Note: Permit is under a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71890	15041-10002-09399	340 N AVENUE 53	90042	1	151-5A225 282	5469012001	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1835.20	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	34.11017	-118.20063	((5/21/2015- CHANGES MADE TO APPROVED SET. DECREASED MODULES FROM 15 TO 14 AND CHANGED INVERTER FROM 5.0 KW TO 3.8KW. PLAN CHECK ONLY APPLICATION)))PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71891	10041-10001-25490	2005 W PICO BLVD	90006	1	129A201   229	5136023031	(T)(Q)CM-1	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	08/22/2011 12:00:00 AM	ADDRESS	34.04702	-118.28177	Delta 1 and Delta 2 modifications to an approved set of  plans.  See included approved plan set.  Adding an additional panel, circuits, decorative water feature subject to CEC 680 fountains, and similar installations, and changing T-24 installed lighting, and some exterior areas.  EPC is for power & energy.  Permit to be issued on the original application number.  Modified pages dated August 22, 2011, to replace the original approved pages.  The permit to cover new items installed as part of Delta 1 and Delta will be issued with the permit issued under ' INPECTION ' for the application number 10041-10000-25490.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71892	15041-20000-08040	10351 W SANTA MONICA BLVD 300	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	03/19/2015 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	PIN	34.0585564	-118.42324002	Plan check for T-24 only for FTVS/FOX21. Total area: 517 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71893	18041-10001-20335	6505 S ESPLANADE #2	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	33.96159	-118.45071	2 OF 5******EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71894	15041-20000-16449	9080 N WOODMAN AVE	91331	6	195B153    22	2642031023	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	02/22/2016 12:00:00 AM	ADDRESS	34.23488	-118.43984	Title 24 plan check only.  Total area = 3,200 sq. ft.  (indoor) + 12,000 (outdoor)T.I. to existing office space.  Replace existing panels (400 A) + new lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71895	16041-10003-41399	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	07/11/2017 12:00:00 AM	ADDRESS	34.27455	-118.56289	CHANGES TO APPROVED SET. CHANGES NOTED DELTA 5 ON PLANS. CHANGE TO CONTROL TYPE. UPDATED FLOOR PLAN ONLY FOR REFLECTED CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71896	16041-10000-20804	3334 S CABRILLO BLVD	90066	11	114B149   133	4247018017	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Issued	06/14/2016 12:00:00 AM	ADDRESS	34.01139	-118.44623	addition of  3.71 kw dc solar system to an existing  system for a single family house.(14) modules: kyocera ku2656zpa(1) inverter: Solaredge SE3000A-us-zb-u .	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71897	15041-20000-35513	11845 W HART ST	91605	2	183B169   239	2321007013	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM	10/22/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	PIN	34.19782551	-118.39152579	PV1 SFD. TOTAL SYSTEM SIZE 7.6KW AC USING CENTRAL INVERTER SYSTEM. USING TOTAL OF 27 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71898	17041-20001-17309	17540 W PARTHENIA ST	91325	12	195B129   455	2787027007	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2017 12:00:00 AM			PC Approved	06/01/2017 12:00:00 AM	ADDRESS	34.22845	-118.51706	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system on a SFD.10.4kW ungrounded system. (33) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71899	12041-10000-04083	3460 W 7TH ST 1-168	90005	10	132B193   313	5093025028	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM	02/27/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.05958	-118.3025	"DELTA ""5"" CHANGES TO A 13 STORIES, 168 UNIT RESIDENTIAL BUILDING.  SERVICE UPGRADE => 2@ 2000 AMP,  INSTALL A NEW 200KW EMERGENCY GENERATOR AND A 150 HP FIRE PUMP."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71900	15041-20001-02776	12476 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	03/01/2015 12:00:00 AM	ADDRESS	33.97888	-118.41041	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71901	11041-10000-02144	700 S FLOWER ST Suite 2100	90017	9	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	04/12/2011 12:00:00 AM	ADDRESS	34.04835	-118.25882	T-24 and emergency lighting plan check for a protion of suite 2100 for Verizon with electrical permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71902	13041-20000-02027	2310 E WHITTIER BLVD	90023	14	124-5A221 273	5189006055	C1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			PC Approved	03/26/2013 12:00:00 AM	ADDRESS	34.03457	-118.21657	Fire repair in an existing retail space.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71903	17041-20000-19372	2131 S DUXBURY CIR	90034	5	126B165   121	4309009021	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2017 12:00:00 AM			Verifications in Progress	08/31/2017 12:00:00 AM	ADDRESS	34.04418	-118.39609	New SFD 600 amps service. Plan check for power only. Project is located in a methane zone.Building permit issued under 16010-30000-01199.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71904	15041-10000-09956	8950 N FULLBRIGHT AVE	91311	12	195B113    33	2781001024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	05/21/2015 12:00:00 AM	ADDRESS	34.23406	-118.5774	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71905	16041-10000-02797	100 N JUNE ST	90004	4	138B185   233	5515003008	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.07414	-118.33414	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.712 KWac. (24) AC MODULES-SUNPOWER SPR-250-BLK-AC (1) 100A LOAD CENTER+	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71906	13041-20001-22450	16167 W ROYAL OAK ROAD	91436	5	162B141   175	2286013008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2013 12:00:00 AM			PC Approved	12/12/2013 12:00:00 AM	ADDRESS	34.14143	-118.48363	((EXPEDITE FEES))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 27KW AC. ROOF MOUNTED. TOTAL OF 90 MODULES. USING TRANSFORMERLESS INVETER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71907	13041-20000-17940	800 S HOPE ST	90017	14	129A209   202	5144020900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	34.0463	-118.25904	RENOVATION OF EXISTING OFFICES. NEW LIGHTING FIXTURES. PC FOR T24 ENERGY ONLY. TOTAL AREA 980 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71908	16041-10000-30395	2121 S AVENUE OF THE STARS #2050	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.05554	-118.41342	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR SUITE 2050. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA SI 5666 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71909	18041-10000-01707	235 N HOOVER ST	90004	13	139-5A201 199	5501004006	R4-1	Central	Wilshire	Rampart Village	YES	2111.21	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	09/11/2020 12:00:00 AM		Issued	09/11/2020 12:00:00 AM	ADDRESS	34.07568	-118.28356	NEW 4 STORY 221 UNIT APARTMENT OVER BASEMENT PARKING GARAGE. (5) DWP SERVICES BEING INSTALLED. RESIDENTIAL SERVICES INCLUDE (1) 1800A, (1) 1400A, 208/120V, 3PH, 4W. COMMERCIAL SERVICES INCLUDE (2) 400AMP, (1) 800 AMP 480/277V, 3PH,4W. 65 TYPICAL UNITS. TOTAL SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71910	12041-10000-04407	700 W WORLD WAY 7H	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/28/2012 12:00:00 AM			Corrections Issued	02/28/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	EMERGENCY LIGHTING AND ENERGY TITLE 24 ONLY.  LAX, TERMINAL 7.  2ND FLOOR.  RETAIL SPACE, 1356SQFT.  SUITE 7H. HARLEY DAVIDSON STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71911	18041-20000-07112	6825 N BIANCA AVE	91406	6	183B129   985	2229005042	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	06/13/2018 12:00:00 AM	ADDRESS	34.19466	-118.51314	PV1.  Install 10 kW AC roof mounted grid tied PV system.  (30) modules with 10 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71912	19041-10000-42079	2125 N DALY ST	90031	1	136-5A221  38	5204008021	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Issued	10/16/2019 12:00:00 AM	ADDRESS	34.07009	-118.21566	PLAN CHECK FOR NEW PV SYSTEMSYSTEM SIZE: 4.03 KW DC; 3.8 KW AC; 13 MODULES (CANADIAN SOLAR 310 WATT MODULES), 13 OPTIMIZERS (SE P320);1  INVERTER (SOLAR EDGE 3.8 KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71913	17041-20000-38126	11846 W SATICOY ST	91605	2	186B169   260	2317009003	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	12/10/2017 12:00:00 AM	ADDRESS	34.20832	-118.3919	Plan check for solar pv system, roof-mounted array on SFD.Total system size: 11.52kW ungrounded.(36) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71914	14041-10000-11751	8931 W VENICE BLVD	90034	5	120B169    27	4312012035	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.02873	-118.38994	T24, Remove HID light fixtures and replace with new florescent fixtures.  Total area 1800 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71915	13041-10000-25063	15851 W VINCENNES ST	91343	12	198B141   220	2671028008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.24109	-118.47807	PV1. ROOF MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 2.64 kW. TRANSFORMERLESS. 1 STORY HOUSE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71916	15041-20002-36835	12901 W JEFFERSON BLVD	90066	11	102B157    89	4211009010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	33.97615	-118.42138	[[[ 3/1/17 CHANGES TO APPROVED SET. DELTA 12 CHANGES ONLY. CONDUIT AND METHANE SEALS AT SERVICE EQUIPMENT MOVED FROM TOP TO BOTTOM.  REMOVE CAMLOCK AND TRANSFER SWITCH]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71917	18041-20001-07567	12669 N ENCINITAS AVE	91342	7	219B141    70	2604035027	[Q]CM-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.29989	-118.47409	10/31/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta D. Marked feeders have been revised and indicated AIC/ISC values have been updated.*****Previous Work Description*****Plan check for power and energy. Project site is an existing single-story commercial building. Project scope is a change of use from school to clinic and a tenant improvement. Work includes an existing utility service and existing distribution panels with all new loads and new subpanels. A Total lighting area = 130,912 sq. ft.Note: Building application has been generated under 18016-20000-04064	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71918	15041-20000-28413	7950 W SUNSET BLVD SUITE #102	90046	4	147B177  1021	5554003055	(Q)RAS4-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			PC Approved	09/08/2015 12:00:00 AM	ADDRESS	34.09777	-118.36322	Plan check for energy only. Change of use from restaurant to gym (exercise studio). New lighting (incl. emergency).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71919	15041-20001-16318	936 S OLIVE ST UNIT 348	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #17 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71920	13041-10000-11479	200 S MAPLETON DR	90024	5	141B157   227	4359011006	RE40-1	West Los Angeles	Westwood	Bel Air - Beverly Crest, Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2013 12:00:00 AM			Reviewed by Supervisor	05/13/2013 12:00:00 AM	ADDRESS	34.08013	-118.43241	ADDITIONS, CHANGES, AND CONSTRUCTION OF SINGLE FAMILY DWELLING. PC FOR LOADS ON SINGLE LINE DIAGRAM. PER INSPECTORS REQUEST, FULL PLAN CHECK PERMIT ALREADY ISSUED UNDER EXPRESS PERMITS. PC ONLY FOR THIS APPLICATION. PC FOR EQUIPMENT TAGGED (N) FOR NEW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71921	14041-20001-25933	21115 W DUMETZ ROAD	91364	3	168B105   324	2167012026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM			PC Approved	10/02/2014 12:00:00 AM	ADDRESS	34.15853	-118.59271	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 15KW INTERCONNECTED WITH MSP.(40) SUNPOWER SPR-E20-327 MODULES(3) POWERONE INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71922	14041-20000-22618	11439 N RUBIO AVE	91344	12	213B137   662	2682002013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.27845	-118.49699	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(22) TRINA SOLAR TSM-255 MODULES(1) ABB PVI-5.0-OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71923	16041-10000-12302	1703 N WILMINGTON BLVD	90744	15	036B201   145	7414006015	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	33.79709	-118.27541	PV1 NEW ROOF MOUNTED SOLAR SYSTEM USING MICROINVERTER. (16) MODULES AND (16) MICRO INVERTERS. TOTAL SYSTEM SIZE  IS 4KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71924	17041-10000-03332	2407-2421 E 1ST ST	90033	14	127-5A223 164	5180002016	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	01/26/2018 12:00:00 AM	ADDRESS	34.04369	-118.20936	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 317 FA DEVICES, AND 4 FA PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71925	16041-10000-37552	18338 W SCHOOLCRAFT ST	91335	3	183B125   710	2125008002	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	05/03/2017 12:00:00 AM	ADDRESS	34.19651	-118.53304	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac.(38)MODULES-AXITEC AXIPOWER AC-265P/156-60S(1)INVERTER-FRONIUS PRIMO 10.0	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71926	13041-10000-26769	890 N TOYOPA DR	90272	11	126B129    71	4411001013	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			09/26/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	06/03/2016 12:00:00 AM	ADDRESS	34.04436	-118.52418	INSTALLING NEW FIRE ALARM SYSTEM FOR CORPUS CHRISTI SCHOOL  AND CHURCH.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71927	13041-10001-32776	1227 N HIGHLAND AVE	90038	4	144B185   362	5532006015	C2-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.09331	-118.33882	CHANGES TO PERMITTED SET OF PLANS TO BECOME AS-BUILT SET OF PLANS; PANELBOARDS  SERIES RATED WHERE REQUIRED ; CHANGES TO CURRENT LIMITER VALUES FOR SOME TRACK LIGHTINGTITLE 24 PART 6 ENERGY LIGHTING WORK FOR AN EXISTING ART GALLERY SINGLE STORY (+MEZZANINE) BUILDING . SCOPE OF WORK IS < 400A. TOTAL SQ FT TO BE 22,787 SQ FT FOR COMBINED INDOOR AND OUTDOOR LIGHTS. LIGHTING IS DESIGNED W/ TAILOR METHOD FOR VARIOUS ART DISPLAYS.  (Complete Plan Check is required)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71928	12041-10000-27215	1233 N MCCADDEN PL	90038	4	144B185   208	5532005040	RD1.5-1XL	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/13/2012 12:00:00 AM			Corrections Issued	11/19/2012 12:00:00 AM	ADDRESS	34.09379	-118.33758	PLAN CHECK FOR TITLE 24. CLASSROOM REMODEL AND NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71929	18041-10000-34264	6180 N LAUREL CANYON BLVD Build. C,D-E,F,PARKIN	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.18261	-118.39631	PLAN CHECK FOR FIRE ALARM SYSTEM FOR -  PARKING STRUCTURE WITH ADDITION OF FOUR RETAIL TENANT AREAS ON GROUND FLOOR CONSISTS OF BUILDING C, D, E, AND F (ALL BUILDING UNDER 1 PERMIT ) - SYSTEM INCLUDE (1) FIRE ALARM NETWORK PANEL LOCATED AT BUILDING C ELECRICAL ROOM, AND 210 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71930	13041-20000-06504	5656 W TUXEDO TER	90068	4	153A191   136	5587002001	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM			PC Info Complete	04/15/2013 12:00:00 AM	ADDRESS	34.11457	-118.31443	New UNGROUNDED Photovoltaic System for the roof of an exisiting single family residence. Permit is on 12041-20000-27870. ***Please ignore disposition, application was for plan check only and has been approved***	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71931	19041-20000-03448	5234 E BALTIMORE ST pv1	90042	1	154-5A225 270	5478017007	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.11775	-118.20213	pv1install roof mounted pv system sized 3.8KW interconnected with msp.(1) LG CHem battery 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71932	11041-10001-05195	2728 S LONG BEACH AVE EAST	90058	9	115-5A213  95	5117017018	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.01137	-118.24273	NEW RECYCLING BLDG.  PLAN CHECK ONLY FOR ENERGY, PERMIT IS ON 11041-10000-05195.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71933	17041-20001-07101	6600 N TOPANGA CANYON BLVD 10984g	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM			PC Approved	04/17/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	4.17.2017 - Plan check for modifications to approved set. Remove fixture E, use fixture A in its place. Update lighting plan and T24 documents to reflect this change. Delta 2 changes.=======ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for energy only.  total sqquare footage 698.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71934	15041-10000-18850	639 S BROADWAY UNIT F	90014	14	129A211   230	5144003040	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Expired	07/12/2017 12:00:00 AM	ADDRESS	34.04587	-118.25309	FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.  ENERGY FEES UNDER APPLICATION NUMBER 15041-10000-18093.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71935	16041-10000-22453	6144 N AUCKLAND AVE	91606	2	177B177   334	2414021013	R2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	08/16/2016 12:00:00 AM	ADDRESS	34.18265	-118.36035	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac. STANDARD PLAN IS BEING USED.(14)MODULES-HYUNDAI HIS-S280RG(1)INVERTER-FRONIUS PRIMO 3.8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71936	10041-20000-20010	7060 W HOLLYWOOD BLVD 5th floor	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/07/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	T.I. existing high rise building at office space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71937	14041-10000-02945	3530 W WILSHIRE BLVD #1060	90010	10	132B193    43	5094001019	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/03/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	04/09/2014 12:00:00 AM	ADDRESS	34.06154	-118.30122	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR SUITE #1060 ON 10TH FLOOR . OFFICE TI. ""NON MEDICAL ROOMS AND OFFICES ( NOT A MEDICAL CLINIC) PER APPLICANT ""3450 SQFT, EMERGENCY LIGHTING. "" ALL WORK TO BE INDOORS """	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71938	17041-10000-36321	2440 S SEPULVEDA BLVD #180	90064	5	123B157  1653	4256008016	M2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.03617	-118.43421	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT OF AN EXISTING SPACE(Testing Facility). NEW LIGHTING AND POWER, NEW ADDED LOAD < 200A.  B# 17016-10000-28448	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71939	14041-20000-01880	1179 N OBAN DR	90065	1	154-5A221 277	5475001009	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Expired	02/29/2016 12:00:00 AM	ADDRESS	34.11688	-118.21768	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER WITH POWER OPTMIZERS. TOTAL OF 16 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71940	17041-10000-03486	5450 W 104TH ST	90045	11	090B173   312	4129034006	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/03/2017 12:00:00 AM	ADDRESS	33.94183	-118.37624	Plan check Title 24 only in existing space office T.I. Toal area: 2,248 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71941	14041-10000-21025	5112 N TEESDALE AVE	91607	2	171B161   723	2357004013	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	PIN	34.16366513	-118.40808479	PV1, INSTALL 7.14 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.28 MODULES AND 2 INVERTERS,	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71942	18041-10000-40834	1883 N DALY ST	90031	1	135A221    35	5210034012	CM-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.06565	-118.21565	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71943	17041-20001-16707	24032 W ARMINTA ST	91304	12	189B089   245	2020031042	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.21347	-118.65094	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (32) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71944	16041-20000-37493	1515 S HOLT AVE	90035	5	129B173   567	4303012059	[Q]R3-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Apartment			10/21/2016 12:00:00 AM			Reviewed by Supervisor	12/09/2016 12:00:00 AM	ADDRESS	34.05074	-118.37913	Plan check for power and energy. Project site is a new 5-story, 21-unit apartment building over 1 level of below-grade parking. Work includes a 1,600-amp service and a total lighting area of 17,535 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71945	17041-10000-42110	6871 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2017 12:00:00 AM			PC Info Complete	11/20/2017 12:00:00 AM	ADDRESS	33.93198	-118.41079	T-24, PC for energy only. Remodel existing office and storage spaces on ground level and add new shower suites and restrooms. Scope includes new lights and receptacles. Total affected area is 1585 Sq. Ft. B#17016-10000-33856	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71946	13041-20000-28905	333 S GRAND AVE 54TH FLR	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.05271	-118.25179	PC FOR T24 ENERGY ONLY. LIGHTING. EXISTING OFFICES. WORK DONE ON 54TH FLOOR OF HIGH RISE. LOAD LESS THAN 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71947	14041-10000-18735	12345 W CHANDLER BLVD 1-23	91607	2	171B165    89	2347006015	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			07/11/2014 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.16879	-118.40229	Installation of new fire alarm system in an apartment. Number of devices = 79. Number of panels = 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71948	12041-10000-03179	2116 W CAMORILLA DR	90065	14	151-5A219 249	5462013100	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2012 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.10842	-118.22698	New roof mounted 1.38KW Enphase M215 Mircoinverter photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71949	16041-10000-42321	9230 N HASKELL AVE	91343	12	198B141   518	2671012028	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1172.02	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.23842	-118.47612	PC FOR ENERGY. REPLACE OUTDOOR FIXTURES WITH NEW LED FIXTURES INCLUDING T24 EXEMPT LIGHTING IN PLAYGROUND. TOTAL AREA 96300 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71950	18041-10000-48430	412 W ANAHEIM ST	90744	15	030B205   436	7416028004	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.7796	-118.26692	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71951	16041-20000-15432	17360 W ANGELAINE WAY	91344	12	219B129   452	2608017007	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.29609	-118.51207	Plan check for PV roof mounted system. System size: 8.4kW with 30 modules and 30 microinverters combined in AC Combiner box. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71952	17041-10000-36848	744 N TULAROSA DR	90026	13	141A203    65	5401007900	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.03	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/07/2017 12:00:00 AM	ADDRESS	34.08231	-118.28036	REPLACE OUTDOOR HID FIXURE WITH  NEW LED FIXURE - TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71953	14041-10000-03206	600 S LA BREA AVE	90036	4	135B181   585	5507023026	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/04/2014 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.06474	-118.34381	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 4 STORY BUILDING. FULLY SPRINKLERED. 1 FACP AND 29 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71954	18041-10000-01512	10556 W PICO BLVD	90064	5	126B157   312	4318002900	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.0441	-118.42053	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 8035 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71955	13041-10000-33103	1639 W 252ND ST	90710	15	036B193   207	7410019029	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	33.79587	-118.30567	PV1. ROOF MOUNTED SOLAR SYSTEM. 1 STORY. SYSTEM SIZE: 3.18KW DC. TRANSFORMERLESS UNGROUNDED SYSTEM.(12) SUNIVA OPT265(12) SOLAR EDGE POWER OPT 250(1) SOLAR EDGE SE3000A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71956	16041-10000-35979	10960 W WILSHIRE BLVD 1800	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	INTERIOR TENANT IMPROVEMENTTO (E) OFFICE; INSTALL NEW LIGHTS AND RECEPTACLES, NEW BRANCH CKTS WITH LOAD BELOW 400A.  (( B# 16016-10000-14723))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71957	19041-10000-30087	12101 W OLYMPIC BLVD	90064	11	123B149   452	4259019008	(T)(Q)C2-2D	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	06/04/2020 12:00:00 AM		Permit Finaled	10/05/2023 12:00:00 AM	ADDRESS	34.0325	-118.45463	FULL PC FOR POWER AND ENERGY. SCOPE OF WORK IS A  NEW 10-STORY MIXED USE OFFICE TOWER. SCOPE OF WORK INCLUDES TWO NEW 4000A SERVICES, A EMERGENCY GENERATOR AT 1250KVA. SCOPE OF WORK ALSO INCLUDES VARIOUS EQUIPMENT, DISTRUBTION BOARDS AND SUBPANELS.B# 19010-10000-02627	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71958	19041-20001-34447	10965 W BLUFFSIDE DR	91604	2	162B173   234	2366021003	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.04	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM			PC Approved	12/03/2019 12:00:00 AM	ADDRESS	34.14159	-118.36889	Expedite per applicant requet Plan check for PV roof mounted system, PV system size: 43.2KW AC, 53.64KW DC, with 149 PV Modues and 3 inverters(14.4KW) connected to 600A Service. One plan has 2 applications. 19041-20000-34431 and 19041-20000-34447	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71959	14041-20000-10308	4408 N CONCHITA WAY	91356	3	165B117   199	2178030015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.14976	-118.56038	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 6.5kW(1) SolarEdge #SE6000A-US-ZB-U transformerless inverter(26) Canadian Solar #CS6P-250PX pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71960	17041-10002-10315	2077 S HARVARD BLVD	90018	10	126B193  1135	5074032018	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.02	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	02/06/2018 12:00:00 AM	ADDRESS	34.03813	-118.30556	Permit fee = $0.00 per senate bill 12222Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71961	18041-10001-40919	518 N CHAUTAUQUA BLVD	90272	11	123B129    80	4411016013	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.03649	-118.51883	NEW ROOF MOUNTED 10.65KW PV SYSTEM WITH 30 PV MODULES AND TWO 17.1 KWH FOR A TOTAL OF 34.2 KWH BATTERY STORAGE UNITS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71962	17041-10000-09458	10250 W SANTA MONICA BLVD #1540	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"PC FOR FIRST TIME TI ""VINEYARD VINES""  IN WESTFIELD CENTURY CITY. SUITE #1540. Total affected area of  2803 sq.ft"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71963	16041-20000-40955	10246 ANGEL LANE	91331	7	204B165   431	2537004041	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.2567927	-118.40421891	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71964	18041-10005-02129	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	PC FOR CHANGES TO APPROVED SET UNDER RFI 314SCOPE INCLUDES ADDITION OF CLOSET SPACE, ONE LIGHT FIXTURES AND T24 REVISION. THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71965	19041-20000-46529	10224 N ARLETA AVE	91331	6	204B153   429	2617007054	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Issued	11/12/2019 12:00:00 AM	ADDRESS	34.25621	-118.44077	PV1.  Install 6 kW DC roof mounted grid tied PV system.  (16) modules with 6 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71966	18041-10000-07049	340 S MESA ST	90731	15	018B201   827	7455014029	R4-2	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	02/27/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.7411	-118.28554	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 60075 SQ.FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71967	14041-20000-01486	132 N LAUREL AVE	90048	5	138B177   509	5511003020	R1-1	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.07534	-118.36462	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 7.6 KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71968	19041-10000-17707	10965 W WEYBURN AVE	90024	5	135B149   594	4363017009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	34.06239	-118.44756	Energy plan check for a restraurant T.I. Scope includes new lighting and equipment with a total lighting area of 2,249-SQ FT.Note. Portion of permit fee is paid under 19041-10000-13302.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71969	17041-20000-12074	20348 W ABERDEEN LANE	91326	12	213B109   776	2701094021	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.283	-118.57827	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD ACM PLAN. SYSTEM SIZE: 5.8 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71970	18041-10000-02087	7402 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20483	-118.49418	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
71971	13041-10001-03510	236 N BUNDY DR	90049	11	135B141   805	4402011007	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2013 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.06268	-118.47638	SUPP. APPLICATION FOR THE ADDITION OF 3 MODULES TO THE PREVIUOSLY APPROVED SET. PC  FOR THE ADDITIONAL MODULES.photovoltaic system for single family single story dwelling. total system size of 7.5 kw. using 30 panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71972	14041-10000-14233	400 S WESTERN AVE 104	90020	10	135B193   439	5503014026	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	01/02/2015 12:00:00 AM	ADDRESS	34.067	-118.30888	Title 24 onlyT.I. for existing restaurant total area = 3700 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71973	12041-10000-04111	400 W WORLD WAY TERMINAL4-#4E	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM			PC Approved	04/10/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	INTERIOR BUILTUP  240 SQ FT   FOR SUNGLASS HUT SPACE  4E, TERMINAL 4. EPC IS FOR T24, ENERGY, AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71974	14041-20000-01719	3856 S NORMANDIE AVE	90037	8	117B197   760	5037009017	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Closed	03/23/2016 12:00:00 AM	ADDRESS	34.01589	-118.30001	New fire alarm for a new 21 unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71975	18041-10001-08790	1633 S 6TH AVE	90019	10	126B189   434	5072016005	RD2-1XL-O-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Apartment			01/09/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.04265	-118.32384	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.12KWAC.(13)MICROINVERTERS-ENPHASE IQ6-60-2-US MICROINVERTERS(13)MODULES-LONGI LR6-60 285W MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71976	19041-30000-04254	1801 CENTURY PARK EAST 20th Floor	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	PIN	34.0621869	-118.41581732	Plan check for Title 24 only. Project site is the 20th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,390 sq. ft.Note: Building permit has been issued under 19016-30000-01094	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71977	16041-20000-45450	341 S KENMORE AVE 1-63	90020	10	135B197   399	5502004015	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Commercial			12/28/2016 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.06776	-118.29683	permit fee $0.00 by state senate bill no.1222PV2.  Install 36 kW AC roof mounted grid tied PV system.  (132) modules with (6) 6kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71978	17041-10000-34329	2911 W BEVERLY BLVD	90057	13	138A201   301	5156019030	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Issued	11/02/2017 12:00:00 AM	ADDRESS	34.07133	-118.28058	Install new rooftop solar system on a multi tenant commercial building, 32.86 kW DC system.  (124) modules with (124) enphase microinvertersZEO PERMIT FEE IS DUE TO SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71979	15041-10000-27875	10 N UNIVERSAL CITY PLAZA	91608	4	162B177   352	2424044020		South Valley				1437.00	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	04/07/2016 12:00:00 AM		Issued	04/07/2016 12:00:00 AM				PC FOR POWER AND ENERGY FOR A HIGH RISE BUILDING ON THE 36TH FLOOR. REPLACEMENT OF CHILLERS AND ASSOCIATED MECHANICAL EQUIPMENT LOCATED ON THE 36TH FLOOR. NEW 4160V UNIT SUBSTATION IS ADDED WITH TRANSFORMER AND DISTRIBUTION SYSTEM TO SUPPORT POWER SUPPLY TO NEW MECHANICAL EQUIPMENT INSTALLATION. TOTAL AREA IS 2960 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71980	15041-20000-42792	16626 W ARMINTA ST	91406	6	189B137    43	2205009036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM			PC Info Complete	09/01/2016 12:00:00 AM	ADDRESS	34.21474	-118.49572	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVMENT FOR OFFICES AND WAREHOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71981	13041-20000-24391	4232 N BAKMAN AVE	91602	2	165B173   839	2366014005	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2013 12:00:00 AM	09/06/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.14588	-118.37775	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.5 KW AC USING 16 MODULES. USING ENPHASE M215 MICROINVERTER USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
71982	12041-20000-02809	14362 W SAYRE ST	91342	7	219B153   175	2507020010	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2012 12:00:00 AM			PC Info Complete	02/21/2012 12:00:00 AM	ADDRESS	34.29895	-118.44586	New enphase M215 inverter system installed on roof of SFD.  Two strings of 11 one combiner panel, and upgrade residential service to 200 amperes.  Zoning clerence was orignally obtained for an express permit, #11041-20000-25164.  Permit issued on application 11041-20000-25164 and 11041-20001-25164.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71983	17041-10000-21918	10250 W SANTA MONICA BLVD #1300	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	09/22/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Plan check for power and Title 24.  T.I. for first time tenant ""Brilliance New York"" in Westfield Century City.  New beauty salon and retail space.  New 45 kVA transformer to feed one subpanel with lighting and receptacle loads.  Lighting area = 989 sq. ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71984	14041-20000-03380	145 S LA BREA AVE	90036	5	138B181  1064	5513019040	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			02/06/2014 12:00:00 AM			PC Approved	02/06/2014 12:00:00 AM	ADDRESS	34.07229	-118.34423	ALL LIGHT FIXTURES ARE EXISTING. CREATED WALL PARTITIONS TO CREATE NEW CONFERENCE ROOMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71985	18041-10001-02493	1353 W 60TH PL	90044	9	105B197   439	6003017023	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2372.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	33.98513	-118.2998	Void application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71986	13041-20000-31392	21747 W ERWIN ST 1ST FLOOR	91367	3	177B105   124	2146029017	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM			PC Approved	11/08/2013 12:00:00 AM	ADDRESS	34.18325	-118.60307	T24 FOR EXISTING FITNESS CENTER. SCOPE OF WORK ON THE FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71987	10041-10000-02886	4480 S CRENSHAW BLVD	90043	8	111B185   178	5013022020	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.00	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	02/23/2010 12:00:00 AM		Permit Finaled	07/16/2010 12:00:00 AM	ADDRESS	34.00268	-118.33041	two story charter school, 59 devices and 1 panel. new system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71988	11041-10000-18140	808 S WALL ST	90014	14	126A211   205	5145010027	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM			Corrections Issued	08/25/2011 12:00:00 AM	ADDRESS	34.03982	-118.25056	NEW EMERGENCY LIGHTING FOR AN EXISTING 8-STORY COMMERCIAL BUILDING IN ORDER TO COMPLY WITH CODE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71989	17041-20000-12566	307 N WILMINGTON BLVD camino del-mar	90744	15	027B205   209	7417010905	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			04/18/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.77243	-118.27378	4/18/2017Changes to an approved set of plans.  Changes noted delta 5.  Changes reflect energy, panels and circuits.(((Plan check for new appartment building 12 residential buildings, with total of 88 units, include new services, site lighting, community blde. Total area: 2000 sqft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71990	10041-20000-22555	1621 S PONTIUS AVE	90025	5	129B149   183	4324035005	M1-1	West Los Angeles	West Los Angeles	Westwood		2673.00	Electrical	Electrical	Commercial			11/10/2010 12:00:00 AM	11/10/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	34.04819	-118.44579	fire damage energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71991	13041-10000-15314	380 WORLD WAY T41	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Info Complete	08/14/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLAN CHECK ONLY. FIRST TIME TENANT AT TOM BRADLEY INTERNATIONAL AIRPORT. PERMIT HAS BEEN PULLED UNDER APPLICATION NUMBER 13041-90000-14278.*****************************************************************13041-90000-14278. DESCRIPTION: PROPOSED 1841 SQFT. Electrical TENANT IMPROVEMENT FOR RETAIL SPACE (RELAY) Space T41	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71992	18041-10000-45561	2303-2500 S SIGNAL ST Berth-58, 59, 60	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	02/04/2019 12:00:00 AM		Permit Finaled	10/16/2019 12:00:00 AM	ADDRESS	33.72469	-118.27449	New Fire alarm system for Community Center. Scope includes (1) fire alarm panels, (2) control panels and (74) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71993	10041-10000-15758	617 W 7TH ST 3RD FLOOR	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM			PC Approved	08/12/2010 12:00:00 AM	ADDRESS	34.04779	-118.2571	TI IN AN EXISTING OFFICE AREA ON THE 3RD FLOOR. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71994	15041-10000-13307	921 S CROCKER ST # C03	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/04/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	FIRST TENANT IN RETAIL SPACEFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71995	19041-10000-39915	11517 N BIANCA AVE	91344	12	213B129   250	2607011020	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM			PC Approved	10/23/2019 12:00:00 AM	ADDRESS	34.2799	-118.51422	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET. CHANGES TO THE INTERCONNECTION OF THE PV SYSTEM TO THE MAIN PANEL FROM LINE SIDE TO LOAD SIDE.PERMIT FEES ARE PAID UNDER 19041-10000-29205  ((PV1. NEW ROOF MOUNTED 12.35KWdc 15.2KWac PV SYSTEM WITH 38 PV PANELS AND 38 OPTIMIZERS (P340) INTERCONNECTED WITH (2) INVERTERS (SE7600H).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
71996	19041-10000-34032	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	North Westwood		2655.10	Electrical	Electrical	Commercial			08/28/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.05885	-118.44283	PC for T24 for a TI for conversion from office to a bank. Total affected area is 8709 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71997	10041-20000-09964	817 W 34TH ST	90089	9	120A201    60	5039003028	[Q]R4-1	South Los Angeles	South Central Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM			PC Info Complete	05/26/2010 12:00:00 AM	PIN	34.02324142	-118.28418096	energy plan check parking lot	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
71998	11041-20000-22146	1250 W JEFFERSON BLVD	90007	8	120B197   676	5040028027	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			10/17/2011 12:00:00 AM	12/13/2011 12:00:00 AM		Permit Finaled	01/18/2012 12:00:00 AM	ADDRESS	34.02528	-118.29315	Plan check for roof mounted 3.29KW PV System for Apartment Bldg #1250. Original approved plans was 9.67KW PV system #11041-20000-16194.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
71999	12041-10000-10688	211 S AVENUE 20	90031	1	138A221   176	5447024033	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	05/29/2012 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.07213	-118.22001	New Fire alarm system for an existing private school.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72000	12041-10001-24034	901 S FLOWER ST	90015	9	129A207   333	5138017***	C2-4D, [Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	11/19/2012 12:00:00 AM		Permit Expired	12/12/2014 12:00:00 AM	ADDRESS	34.04579	-118.26176	First time tenant for a design studio. T24 plan check  & permit were done under separate application. (App# 12041-10000-24034).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72001	12041-10000-28659	7659 N SAN FERNANDO ROAD	91352	2	186B177   563	2466036***	M2-1, [T][Q]M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Expired	12/24/2014 12:00:00 AM	ADDRESS	34.20892	-118.35711	Plan check for power 1200 amps feeder , and 5 non d equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72002	13041-10000-00919	15826 W VENTURA BLVD	91436	5	168B141   641	2283009002	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	12/02/2013 12:00:00 AM	ADDRESS	34.15544	-118.47848	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS. REMODELING EXISTING FAST FOOD RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72003	11041-20000-25822	10990 W WILSHIRE BLVD Ste 140	90024	5	132B149   138	4324002***	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/05/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Finaled	01/09/2012 12:00:00 AM	ADDRESS	34.0577	-118.44711	Existing fire alarm.  Tying in one new power supply and 10 new devices for suite # 140.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72004	13041-10000-14393	800 W OLYMPIC BLVD	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	09/13/2013 12:00:00 AM	ADDRESS	34.04484	-118.26453	T24 only on 4th floor , no adding of load.  Relocating fixtures and adding some.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72005	19041-10000-06356	403 W ADAMS BLVD A-B	90007	9	121-5A205 317	5126017018	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02746	-118.27394	Fire Life Safety System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72006	13041-10000-24730	643 N MARIE AVE	90042	14	157-5A231 111	5483012024	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	11/26/2013 12:00:00 AM	ADDRESS	34.12709	-118.18162	PV1.  Instal 2.0 kW DC roof-mounted solar array of 8 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72007	18041-10000-12408	8500 N VAN NUYS BLVD	91402	6	192B149   148	2638001046	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.22511	-118.44865	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURE AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72008	17041-10002-27724	8119 N GEYSER AVE	91335	12	189B121    68	2103002030	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	34.21805	-118.54281	Supplemental PC for changes to approved set. Changing main panel from 400A to 225A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72009	10041-20000-02950	4741 N LAUREL CANYON BLVD	91607	2	168B165   601	2356037036	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	Commercial			02/19/2010 12:00:00 AM	02/19/2010 12:00:00 AM		Permit Finaled	03/11/2010 12:00:00 AM	ADDRESS	34.15689	-118.39668	Change of Use and T.I. (1882.75 sqft at first floor) to portion of existing 2-story office building to Retail:  Removal of existing partition walls .ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72010	17041-10000-25933	1010 E JEFFERSON BLVD	90011	9	115-5A209  94	5114015045	(T)(Q)CM-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	01/28/2019 12:00:00 AM	ADDRESS	34.01202	-118.258	Install New Fire alarm system on a 41 unit apt. building. (5) panel,  (175) devices	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72011	19041-10000-45644	12802 W WENTWORTH ST	91331	6	198B161   395	2629027***	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM			Reviewed by Supervisor	11/20/2019 12:00:00 AM	ADDRESS	34.23654	-118.41166	INSTALLING A NEW 277/480V, 3,000 AMP SERVICE. CORE AND SHELL ONLY. NO CONNECTED LOAD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72012	19041-20000-34521	12122 W HESBY ST	91607	2	171B165  1011	2356004009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2019 12:00:00 AM	08/30/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.16203	-118.39741	PV1.  Install 10.54 kW roof mounted grid tied PV system.  (34) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72013	12041-10000-03148	16645 W SATICOY ST	91406	6	186B137    10	2205009800	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			02/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	ADDRESS	34.20857	-118.49606	New service, panels, and a compresor for the southern California Gas Company fuel station.  EPC for power. (Hazardous area, Class I, Div1& 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72014	18041-10000-39404	2821 N FIGUEROA ST	90065	1	142-5A221 145	5446010029	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.08534	-118.22074	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72015	19041-20000-07815	700 S FLOWER ST 4TH FLOOR-SUITE B	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	T24 PLAN CHECK FOR EXISTING COMMERCIAL BUILDING STE B. TOTAL SQUARE FOOTAGE = 4144 SF. LIGHT AND RECEPTACLES, 1 225A PANEL, AND 1 WATER HEATER (8.3 KVA)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72016	17041-10000-35823	900 N ALAMEDA ST 2nd floor	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			10/05/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC FOR T.I. of existing office on 2nd floor (data center building) FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS AND LIGHTS. TOTAL AFFECTED 950SQ. FT. B# 17016-10000-24408	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72017	15041-10001-17997	9000 S BELLANCA AVE	90045	11	096B169  1077	4125010011	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.95506	-118.38038	02/04/16Changes to an approved set of plans. All changes made under delta 2. Converting part of warehouse into office space. Changes include adding outdoor lighting, and removing/replacing lighting fixtures in office and warehouse spaces. total hardscape area is 17190 sq. ft. (((TO AN EXISTING WAREHOUSE.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 74312 INDOOR/OUTDOOR.(((permit pulled with notorized authorization letter)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72018	14041-10000-35924	717 S MATEO ST	90021	14	124-5A217 298	5166016015	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.03397	-118.23243	Power plan check for an 800-Amp service upgrade (From 400Amp to 80Amp). Core and shell only. Plan check is needed for tenant space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72019	14041-20001-19806	5058 N FLORISTAN AVE	90041	14	162A227   183	5689022023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2014 12:00:00 AM			PC Approved	08/20/2014 12:00:00 AM	ADDRESS	34.13858	-118.19863	Relocate equipment including meters, main panel board, inverter, and DC disconnect. Instead of Weeb-PMC Snap and Rack, contractor use  lug to screw grounding conductor to each PV module.(((3.5KW PV1 roof-mounted system with (14) Renesola Solar JC250 modules, (14) Solaredge power optimizers P300, and (1) Solaredge SE3800A-US transformerless inverter)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72020	18041-30000-40525	15232 W SHERMAN WAY	91405	6	183B145  1117	2220022015	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	34.20089	-118.46542	Plan check for T24 only, TI to an (E) pharmacy space inside the CVS. New loads are fed from existing panels. Total area: 1,337 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72021	10041-10000-23460	1664 1/2 W CORDOVA ST	90007	1	126B197   880	5075038012	M1-1	South Los Angeles	South Los Angeles	Pico Union		2216.02	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM			PC Approved	11/24/2010 12:00:00 AM	ADDRESS	34.03887	-118.29354	T24 lighting plan check for office space.  existing permit 10041-10000-22927.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72022	17041-20000-29179	12501 W BURBANK BLVD #6	91607	2	174B165   723	2341017040	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1244.00	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	08/16/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.1723	-118.40553	Plan check for energy only. TI to restaurant (Domino's Pizza). T24 area - 815sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72023	15041-20002-00172	18654 W PARTHENIA ST	91324	12	195B121   416	2785002025	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			03/20/2015 12:00:00 AM			PC Approved	03/20/2015 12:00:00 AM	ADDRESS	34.22809	-118.54008	Change to approved set of plan. (((T.I. to existing building.  Install indoor general/emergency lighting.  Plan check for energy only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72024	15041-20001-43922	19530 W PRAIRIE ST	91324	12	198B117   253	2761035014	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			04/05/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.23892	-118.56107	[[4/5/16 supplemental plancheck for outdoor lighting in common street, driveway and walkways. Plan check for new common area in a condo complex. Plan check for energy only. Adding new lighting and receptacles. Total sqft. 647 (cond) + 1818 (uncond).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72025	18041-30000-45975	10100 W SANTA MONICA BLVD STE 180	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM			PC Info Complete	12/04/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	PC for energy only. Tenant improvement to Suite 180 (1,767 SF).  Scope of work to includes new lighting and receptacles in an existing high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72026	11041-10000-20662	1430-1434 S ELKGROVE CIR BLDG 13	90291	11	111B149   486	4243001033	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	ADDRESS	34.00125	-118.45783	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72027	15041-20001-29516	21217 W DE LA GUERRA ST	91364	3	171B105   532	2167004006	R2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Apartment			09/08/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	34.16479	-118.59505	Expedite per applicant request{{{{{Plan check for PV roof mounted system in multi-family complex. System size: 5.0kW with 25 modules and 1 inverter(5.0kW)}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72028	10041-20000-00691	2700 S FIGUEROA ST	90007	9	121-5A203 113	5123018031	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	04/08/2010 12:00:00 AM		Permit Finaled	09/01/2011 12:00:00 AM	ADDRESS	34.02708	-118.27647	NEW 5 STORY 161 UNIT MIXED USE BUILDING.   STUDENT HOUSING AND 1ST FLOOR COMMERCIAL.   VARIANCE FILED TO SEPERATE FIRE ALARM.Request for Modification to separate Methane Detection system submited 04.06.2010	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72029	19041-10000-05296	1958 N GRAMERCY PL	90068	4	150A193    23	5587021002	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Expired	11/05/2023 12:00:00 AM	ADDRESS	34.10692	-118.31288	NEW ROOF MOUNTED 9.975KW PV SYSTEM WITH 420 PV TILES ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72030	16041-20001-24156	5250 N LANKERSHIM BLVD	91601	2	171B173  1421	2350018090	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM			PC Approved	07/20/2016 12:00:00 AM	ADDRESS	34.16668	-118.37545	Plan check for re-wire the feeders for 4 existing A/C units{{{{{Refeed 4 existing compressors.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72031	12041-10000-02517	3341 W 43RD PL	90008	8	114B185  1144	5024019902	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM	02/06/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.00441	-118.33097	New fire alarm system for an existing theatre and arts center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72032	12041-20001-04083	3460 W 7TH ST 1-168	90005	10	132B193   313	5093025028	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			02/19/2013 12:00:00 AM	03/07/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.05958	-118.3025	"Changes to previously approved set of plans under 12041-10000-04083. Relocation of fire-pump, addition of meter (electricity rate) to fire pump, changes to lighting. All changes have been clouded.DELTA ""5"" CHANGES TO A 13 STORIES, 168 UNIT RESIDENTIAL BUILDING.  SERVICE UPGRADE => 2@ 2000 AMP,  INSTALL A NEW 200KW EMERGENCY GENERATOR AND A 150 HP FIRE PUMP."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72033	10041-10000-25777	990 W HARRY BRIDGES BLVD	90744	15	027B205   482	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM			Verifications in Progress	04/04/2012 12:00:00 AM	PIN	33.77039336	-118.27293856	NEW ENTRY ID GATE CANOPY FOR PORT OF LA. EPC IS FOR POWER AND ENERGY.  (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72034	18041-10000-06119	7901 N WOODLEY AVE	91406	6	189B141   129	2205004039	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.21426	-118.48387	REMOVEOUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72035	14041-10000-23347	14318 W CALVERT ST	91401	6	177B153   662	2240009009	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			08/26/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.18156	-118.44496	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Scope does not include emergency lighting which is existing to remain.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72036	18041-20000-25388	1308 1/2 N MALTMAN AVE	90026	13	142-5A203 507	5427022041	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.08647	-118.27882	PV1.  Install 5.49 kW roof mounted grid tied PV system.  (18) modules with 5 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72037	16041-20000-05736	20930 W COMMUNITY ST	91304	3	192B109   921	2779006195	(Q)R1-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.22197	-118.58964	Plan check for the addition of a PV1 roof-mounted PV system onto an existing PV system. Addition system size is 3 kWac, for a total system size of 6.8 kWac. Addition consists of (1) inverter, (10) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72038	18041-10000-10037	9034 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.23415	-118.55337	PC for T24 only for Restuarant TI. Installing two panels, lights, receptacles and equipment. Total area 2927sqft.B# 18016-10000-06973TENANT IMPROVEMENT, ALTERATION TO (E) 27' x 110' RESTAURANT.  Remove replace partitions, counters and finishes. Upgrade restrooms.  Increase dining room occupant load to 97.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72039	16041-10000-40313	1553 N SCHRADER BLVD	90028	13	148-5A187 334	5547018029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.09953	-118.33258	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 15975 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72040	17041-20000-30580	3255 W WILSHIRE BLVD ste 120	90010	10	135B197  1185	5502026020	C2-2, C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Finaled	02/08/2018 12:00:00 AM	ADDRESS	34.06195	-118.29324	ti to an existing dental offfice in a high rise buiding.  adding new lighitng new controls to existing panels.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72041	11041-20000-26598	7002 W CLINTON ST	90036	5	141B181   907	5525020011	RD1.5-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/13/2011 12:00:00 AM			Reviewed by Supervisor	12/28/2011 12:00:00 AM	ADDRESS	34.08176	-118.34333	preschool new building 800amps service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72042	17041-10000-26092	16606 W SCHOENBORN ST	91343	12	192B137   259	2689010009	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Issued	08/01/2017 12:00:00 AM	ADDRESS	34.22244	-118.49433	TITLE 24 PLAN CHECK FOR REMOVAL OF (5) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA = 8400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72043	10041-10001-05231	2930 E WHITTIER BLVD	90023	14	123A223   248	5189004040	C1-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2047.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM			Corrections Issued	04/14/2011 12:00:00 AM	ADDRESS	34.03069	-118.20803	Change the approved plan. Addition of a panel and branch circuits.  EPC is for delta 6 changes. (((((((((((Plan check power and energy for new service upgrade from 400A to 800A. New switchboards, panels, equipments, and ckts.))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72044	10041-10000-13715	317 W PACIFIC COAST HWY	90744	15	036B205   998	7421024014	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			07/16/2010 12:00:00 AM	09/29/2010 12:00:00 AM		Permit Finaled	11/24/2010 12:00:00 AM	ADDRESS	33.79117	-118.26668	Retail Store changed to a New Bank. Existing Service, New Panels & Circuits. Applicant is requesting EPC. Plan Check is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72045	18041-20000-38759	7001 S LA TIJERA BLVD	90045	11	102B173   219	4103008016	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Apartment			10/10/2018 12:00:00 AM	10/10/2018 12:00:00 AM		Permit Finaled	05/07/2020 12:00:00 AM	ADDRESS	33.97512	-118.37472	Plan check for new fire alarm for 23 units multi-residential building 3 story. Total fire alarm device: 83 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72046	18041-20000-27045	1213 N AMALFI DR	90272	11	129B133    96	4425007003	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM			PC Approved	09/25/2018 12:00:00 AM	ADDRESS	34.05187	-118.50615	New 2-story SFD with 800A 208Y/120 3ph-4w service.  Plan check for power.Building permit under 18010-20000-01150	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72047	16041-10000-40884	350 S FIGUEROA ST STE 1002	90071	14	132A209   228	5151011027	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/18/2016 12:00:00 AM	11/23/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.05438	-118.2549	Title 24 plan check.  T.I. on 10th floor of existing commercial office highrise building.  New 45 kVA transformer, 125 amp panel, lighting, and receptacle loads.  Total area = 8,155 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72048	14041-20000-25430	7455 N ETIWANDA AVE	91335	3	186B125   479	2119014002	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.20637	-118.53182	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 3.8kW.(1) SolarEdge SE3800A-US-ZB-U transformerless inverter(20) SolarEdge P300 power optimizers(20) Trina Solar TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72049	14041-20000-07637	10334 W TENNESSEE AVE	90064	5	129B161   248	4315016024	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM	03/21/2014 12:00:00 AM		Permit Expired	04/14/2016 12:00:00 AM	ADDRESS	34.04982	-118.41645	PV1 MICROINVERTER NONSTANDARD PLAN. TOTAL SYSTEM SIZE 2.33KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72050	14041-20000-09621	12746 W JEFFERSON BLVD	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	08/11/2014 12:00:00 AM		Permit Closed	05/21/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	PC FOR NEW 600A AND MINOR DISTRIBUTION FOR FUTURE TENANT. THIS IS SHELL ONLY. NO LOADS AT THIS TIME. POWER ONLY. FUTURE TI SUBJECT TO PLAN REVIEW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72051	19041-20000-13105	14610 W DEL PLAYA ST	91402	6	201B149   361	2650019024	(Q)RD2-1, (Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	04/10/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.24776	-118.45086	Plan check for PV roof mounted system, system size: 3.02KW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72052	19041-30000-11797	3431 S CATALINA ST	90007	8	120B197   729	5040019016	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	Apartment			04/02/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Closed	06/29/2020 12:00:00 AM	ADDRESS	34.0246	-118.29404	Plan check for a fire alarm system for a 4-story, 7-unit apartment building with a basement. System consists of (1) FACP and (36) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72053	15041-20000-14311	707 W WILSHIRE BLVD 24th Floor	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	06/15/2015 12:00:00 AM		Permit Finaled	08/24/2015 12:00:00 AM	ADDRESS	34.04893	-118.2572	Title 24 plan check only.  Total area = 6,200 sq. ft.  T.I. to existing commercial highrise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72054	14041-20000-18381	20643 W KITTRIDGE ST	91306	3	180B109   408	2148018013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.19018	-118.58364	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(16) TRINA SOLAR TSM-255 MODULES.(1) SOLAREDGE SE3800 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72055	13041-10002-07497	1701 E CESAR E CHAVEZ AVE SUITE 545	90033	14	130-5A221 204	5174007047	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	34.05126	-118.2173	TI FOR A MEDICAL SUITE IN A 5-STORY BUILDING.  WORK BEING DONE ON 5TH FLOOR, SUITE 545.  FULL POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72056	15041-20000-23263	17476 W CANDIA ST	91344	12	219B129   398	2608013022	RE11-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			07/21/2015 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.29713	-118.51518	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system (standard plan)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72057	12041-10001-16118	12852 W RUNWAY ROAD	90094	11	102B157   392	4211033033	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM	02/19/2014 12:00:00 AM		Permit Closed	03/06/2014 12:00:00 AM	ADDRESS	33.97543	-118.41892	][][]CHANGES MADE TO AN APPROVED SET OF PLANS; CHANGING FEEDERS (TO PANELS) FROM COPPER TO ALUMINUM; cogen and pv systems are not under this plan reviewNew 2-story community center w/ exercise rooms, meeting rooms, classrooms, and pool deck.  Full Plan Check for Power and Energy.  Site is in a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72058	16041-10000-00210	19234 W FRANKFORT ST	91324	12	192B117   712	2784019027	R1-1	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	34.22085	-118.55241	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KW-ac(23)MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72059	15041-10001-12879	4334 S DEGNAN BLVD	90008	10	114B185  1143	5024019008	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.00494	-118.33125	6/30/15: CHANGES TO AN APPROVED SET, NOTE CHANGES IN DELTA 1. CHANGES INCLUDE REVISIONS TO UNIT EQUIPMENT AND ADDITIONS TO EXISTING RECEPTACLES. (((TI-24 TO AN (E) 2 STORY BUILDING. CONVERTING TO LED LIGHTING. TOTAL SQ. FT. 3211)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72060	13041-10000-04320	1829 N AVENUE 55	90042	14	157-5A227 214	5479009023	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1833.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.1256	-118.19781	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY SINGLE STORY DWELLING. PC FOR PV SYSTEM. USING ENPHASE M215-60-2LL-S22. USING SOLAR PANELS REC 245 PE. TOTAL SIZE 3.624KW. 17MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72061	17041-10000-23753	15342 W ROSCOE BLVD	91402	6	192B145   432	2654035017	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.22126	-118.46721	T-24, REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72062	17041-10001-16365	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Changes to an approved set of plans. All changes are clouded under delta 2. Changes include relocating lighting lighting fixtures on the lighting floor plans. Note: Permit is paid under PCIS#17041-10000-16365	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72063	13041-10000-32753	1500 W PACIFIC COAST HWY BLDG F2	90744	15	033B201     2	7412009007	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			11/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/16/2017 12:00:00 AM	ADDRESS	33.79072	-118.2857	METHANE MITIGATION SYSTEM FOR NEW MULTIPLE APARTMENT AND POOL/RECREATION BUILDINGS. BUILDING F2THIS IS IN CONJUNCTION WITH PLAN CHECK # B13LA09331	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72064	15041-10000-36629	700 W WILSHIRE BLVD 7TH FLR	90017	14	129A209    65	5144006020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.04863	-118.25733	T-24, CHANGE OF USE/OCCUPANCY OF 7TH FLOOR OF THE OFFICE HIGHRISE FROM OFFICE TO COMMUNITY BANQUET HALL. Max 190 occupant].SCOPE INCLUDES NEW LIGHITNG AND RECEPTACLES. TOTAL SQ. FT. 4480	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72065	18041-20000-11914	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	08/27/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan check for Title 24 only in new sprung conopy to house baggage handling equipment(Carousel). Total area: 3,289 sq ft(This permit also covered supplemental plan under 18041-10000-32672)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72066	14041-20001-04036	4038 N STONE CANYON AVE	91403	4	163-5A147  32	2277023010	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM			PC Approved	04/09/2014 12:00:00 AM	ADDRESS	34.14411	-118.46074	((CHANGE OF SINGLE LINE DIAGRAM. ADDITION OF DWP METER SHOWN. CHANGE CLOUDED.$0 FEE DUE TO SENATE BILL 1222 FROM 2012	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72067	17041-20000-07737	7002 W CLINTON ST	90036	5	141B181   907	5525020011	RD1.5-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.08176	-118.34333	new gym.  plan check for hazardous loaction (methane zone) and power and energy.  total square footage 4656.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72068	12041-10000-06320	1542 W PALOS VERDES DR NORTH BLDG T	90732	15	030B193   203	7442001021	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	2951.01	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	07/25/2012 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	33.7793	-118.30482	Plan check 164.97KW roof mounted photvoltaic system for charter school. Modules on each building supplying one central inverter. Building T. Methane Buffer Zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72069	16041-10000-30257	6047 N HAZELHURST PL	91606	2	177B169   656	2334014054	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Apartment			08/25/2016 12:00:00 AM	10/09/2019 12:00:00 AM		Issued	10/09/2019 12:00:00 AM	ADDRESS	34.18071	-118.3865	PC for power and energy. New 4- story  12- unit apartment building over 1- level of basement garage. 800A service. total area 8094 sq ft.B # 16010-20000-01836	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72070	18041-20000-37925	20010 W VENTURA BLVD	91364	3	174B113   458	2166001019	C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	06/03/2019 12:00:00 AM	ADDRESS	34.17154	-118.56877	ti to an existing commercial building.  adding new lighting new controls to new panel.  newly connected load <400 amps plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72071	13041-10000-33695	5234 N VINELAND AVE	91601	2	171B173   447	2416004009	CM-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	03/21/2014 12:00:00 AM	ADDRESS	34.16591	-118.37015	PLAN CHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 3639 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72072	14041-10000-17058	4044 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181   497	5032007001	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	03/04/2015 12:00:00 AM		Permit Finaled	07/14/2016 12:00:00 AM	ADDRESS	34.01588	-118.34384	PC FOR POWER AND ENERGY. NEW CAR WASH . TOTAL AREA 16697 SQ.FT(INDOOR+OUTDOOR+FACADE).BUILDING APPLICATION # 13010-10000-00943.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72073	09041-10001-09410	3429 W OLYMPIC BLVD	90019	10	129B193   235	5081032010	C2-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Expired	12/24/2015 12:00:00 AM	ADDRESS	34.05282	-118.31276	MODIFICATION TO AN APPROVED SET OF PLANS.  APPROVED SET OF PLANS ARE INCLUDED.  ALL CHANGES ARE CLOUDED.  PLAN CHECK IS FOR ENERGY AND POWER.  <<<<<<New 25 unit condominium building. These plans shall replace the original plans checked w/ PCIS # 06041-10000-20757 because the building was completely changed.>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72074	13041-20001-34916	5601 N DE SOTO AVE BASEMENT	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.17126	-118.58861	"][]CHANGES MADE TO APPROVED SET OF PLANS (13041-20000-34916); CHANGES WILL BE TO REPLACE THE 48"" LONG PENDANT FLUORESCENT WITH LED FIXTURES;  NEW CONNECTED LOAD < 400A ][][PC FOR T24 ENERGY ONLY. NEW LGIHTING IN BASEMENT. POWER LESS THAN 400A. NO PATIENT CARE CHECK REQUIRED."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72075	18041-20000-03473	16255 W VENTURA BLVD Ste 350	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.15711	-118.48768	Existing commercial office remodel in highrise building.  New lights and existing circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72076	16041-10000-41754	1901 W VENICE BLVD	90006	1	126B197  1203	5075014019	CM-2, PB-1, QCM-1, R3-1, RD5-1, [Q]R4-1, [Q]RD5-1	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.04443	-118.29612	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 219350 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72077	17041-20000-36978	4929 N ARCOLA AVE	91601	4	168B177   141	2420011006	R1-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.16033	-118.35512	PV1.  Adding (4) modules and microinverters to (E) microinverter system for a total 4.4 kW DC PV system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72078	19041-10000-25607	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	PF-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/03/2019 12:00:00 AM			PC Approved	07/03/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	THIS PLAN REVIEW ALLOWS A TEMPORARY WIRING OF THE FIRE PUMP AHEAD OF THE MAIN  IN THE SAME SECTION AS THE MAIN DISCONNECTWILLIAM MITCHELL OF ELECTRICAL INSPECTION HAS ALLOWED HIS CONNECTION AS NEW ELECTRICAL SWITCHBOARD WILL BE INSTALLED AFTER THE END OF THE PRESENT SOCCER SEASON. AND THE FIRE PUMP TAP WILL BE INACCORDANCE WITH THE NEC.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72079	15041-10000-04923	7600 N LAUREL CANYON BLVD	91605	6	186B165   200	2317002031	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.01	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.2088	-118.39632	Plan check for power and energy. Project is a TI to go from a vacant space to a laundromat (space was retail before being vacant; not first time tenant). Project includes the replacement of (6) 200-amp rated panels, with new loads. Service is existing. Total lighting area = 5,588 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72080	10041-10000-12236	20901-20917 W SHERMAN WAY	91303	3	183B109    58	2112017001	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.00	Electrical	Electrical	Commercial			06/28/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	08/17/2011 12:00:00 AM	ADDRESS	34.20126	-118.58873	New three phase service for existing strip center.  No change in loads of tenenat spaces.  Connect one new house panel. with one new sign circuit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72081	12041-10000-16348	3434 S HOPE ST	90007	9	118-5A203  74	5122021010	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Issued	08/30/2012 12:00:00 AM	ADDRESS	34.01983	-118.27801	INSTALLATION OF A TELECOM FACILITY INSIDE AN EXISTING PARKING STRUCTURE @ USC CAMPUS.  New 600A Service, panels, circuits, and lightintg.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72082	11041-10000-13736	5901-5925 N DE SOTO AVE	91367	3	177B109   204	2149002028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Public Safety Only			07/01/2011 12:00:00 AM	07/01/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.17807	-118.5905	new fire warning system in a commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72083	17041-10000-15545	600 S LA BREA AVE	90036	4	135B181   610	5507023031	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.06474	-118.34381	PC  FOR POWER AND ENERGY. CHANGE OF USE FROM  FURNITURE STORE ON FIRST FLOOR TO NEW RESTAURANT. EXISTING 800AMP SERVICE, ADDITION OF 5 NEW 200 AMP PANELS, AND RECONNECTING ONE EXISITING ONE. TOTAL AREA 5017 SQ FT.B # 17016-10000-08355	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72084	15041-20001-02742	12484 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	EXPEDITE PER CUSTOMER EQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72085	16041-10001-10337	9315-9317 W PICO BLVD bldg A	90035	5	132A167   203	4330035012	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.05542	-118.39328	PC FOR CHANGES TO APPROVED SET OF PLANS. PER BUILDING PERMIT, PLAN SHALL BE CHECKED IN ACCORDANCE WITH 2008 ENERGY STANDARDS. ALSO ADDED 4 HP UNITS. PERMIT SHALL BE ISSUED FOR ADDED WORK. ALL CHANGES NOTED DELTA 10	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72086	17041-20000-12440	1900 S WESTWOOD BLVD	90025	5	129B153   740	4321011027	C4-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	08/06/2017 12:00:00 AM	ADDRESS	34.04815	-118.43521	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72087	15041-20000-30650	10773 W LAWLER ST	90034	5	120B161   776	4254025040	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			09/16/2015 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.02433	-118.41418	Plan check for a PV2 roof-mounted PV system. System size is 13 kWac and consists of (2) inverters, (54) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72088	18041-10000-22693	300 E ROSE AVE	90291	11	111B141   675	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	06/07/2019 12:00:00 AM	ADDRESS	33.99652	-118.47669	CONVERT EXISTING STORAGE ROOMS TO ALL GENDER RESTROOM ON 1ST FLOOR 65 SF; 2ND FLOOR 65 SF. TITLE 24 ENERGY ONLY. BLG PERMIT #18016-10000-19335	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72089	16041-10004-13870	8500 W BEVERLY BLVD	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/26/2017 12:00:00 AM			PC Approved	10/26/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	CHANGES TO AN APPROVED SET OF PLANS, CHANGES ARE NOTED ON DELTA 11,12,13. ***FULL PC FOR A CORE AND SHELL RESTAURANT AND VALET AREA IN THE BEVERLY CENTER  WITH A NEW 5000 AMP SERVICE. REPLACEMENT OF RESTAURANT AND VALET AREA LIGHTING. SCOPE OF WORK INCLUDES NEW LIGHTING, RECEPTACLES AND SWITCHGEAR.BUILDING PERMIT # 16016-10000-01909	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72090	17041-10000-46407	4226 N IRVINE AVE	91604	2	165B169   746	2368014029	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2017 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/10/2018 12:00:00 AM	ADDRESS	34.14626	-118.38542	PC FOR INSTALLATION OF NEW ESS. SCOPE INCLUDES TWO TESLA POWERWALL 2  (AC TYPE) WITH NEW SUBPANEL. RESIDENCE HAS EXISTING PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72091	17041-10002-16721	10334 N ORO VISTA AVE	91040	7	204B189   392	2560013007	RD3-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			Verifications in Progress	06/13/2017 12:00:00 AM	ADDRESS	34.25711	-118.31562	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  6 kWac inverter connected to 5 kW 13.5 kWH battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72092	19041-20000-39213	1394 W SUMMERLAND AVE	90732	15	018B193   158	7446004029	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	11/25/2019 12:00:00 AM	ADDRESS	33.74709	-118.30621	Install 9.8 kWh energy storage system and backup load panel/associated distribution.  (E) PV system on site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72093	16041-10000-27695	6380 W QUEBEC DR	90068	4	153A187   231	5576010051	R1-1	Central	Hollywood		YES	1896.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.11349	-118.3281	PV1 INSTALLING NEW 5460 W DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE(21) MODULES: HYUNDAI HIS-S260RG 260W(21) MICROINVERTERS: ENPHASE M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72094	17041-10000-43490	18901 W MUIRKIRK DR	91326	12	219B121   106	2820004027	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2017 12:00:00 AM	12/13/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.29598	-118.54539	New solar system PV1 on a SFD, 11.5 kW AC. Install (32) AC modules, and (1) 125A solar load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72095	18041-10000-25178	7660 W MELROSE AVE	90046	5	141B177   640	5527023003	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	34.08356	-118.35683	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR ANTHEM SHOE STORE. 2228 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72096	14041-20000-31640	11759 W ARCHWOOD ST	91606	2	180B169   259	2322015008	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.03	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	11/14/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.19223	-118.38973	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.22 KW(44) KYOCERA # KD255GX(1) FRONIUS # IG PLUS 10.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72097	12041-10000-20210	1125 W VIA FRANCISCA	90732	15	021B193   102	7445018047	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	33.75427	-118.30297	Plan check for new 7.35KW DC roof mounted photovoltaic system. (3 strings)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72098	19041-10000-47389	6425 N TYRONE AVE	91401	6	180B153   949	2237022023	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			11/18/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.1872	-118.44448	0$ final fees per AB1414PC for PV-2 system, 23.3KW system, 70 Modules with 400p optimizers and 3 7600H solaredge inverters. and 400 Amp service	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72099	18041-10000-11179	1061 N SWARTHMORE AVE # 1-103	90272	11	129B125   836	4423016021	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	09/10/2018 12:00:00 AM	ADDRESS	34.04833	-118.52499	Interior remodel to first tenant (take out restaurant).  FULL PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72100	16041-20000-40723	14624 W SHERMAN WAY 6th flr	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.20102	-118.45165	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.  total square footage 8530. scope on the 6th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72101	18041-10000-38751	1717 N WILCOX AVE	90028	13	148-5A187  95	5547007009	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	04/16/2020 12:00:00 AM		Issued	04/16/2020 12:00:00 AM	ADDRESS	34.10221	-118.33129	FULL PLAN CHECK FOR POWER AND ENERGY. NEW 2000AMP 480/277V 3 PHASE 4 WIRE SERVICE, NEW PANELS, NEW CIRCUITS, AND LIGHTING. TOTAL AFFECTED AREA IS 150,000 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72102	15041-10000-22479	140 E 53RD ST	90011	9	108B205   365	5101012004	R2-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	10/22/2016 12:00:00 AM	ADDRESS	33.99412	-118.27245	PV1.  Install 3.27 kW DC roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72103	18041-30000-36597	740 S RIDGELEY DR	90036	4	132B181   133	5089005011	[Q]R4-1	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Apartment			09/25/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.06127	-118.35077	INSTALL NEW FIRE ALARM SYSTEM FOR  FIVE STORY 25 UNIT MULTI-FAMILY DWELLING, WITH TWO STORY SUBTERRANEAN GARAGE. (1) FACP, (78) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72104	14041-10002-17295	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.05436	-118.25543	WORK IS FOR NEW OFFICE CONVERSION + ROOM 326 AND 328. NO FEE DEPARTMENT ERROR.PLANCHECK FOR T24 ENERGY, TENANT IMPROVEMENT FOR 3RD FLOOR . HIGHRISE. FLOOR CONSISTS OF COMMERICIAL AND HOTEL ROOMS. 2596 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72105	17041-10000-10409	3701 N COLDWATER CANYON AVE	91604	2	162B161   513	2385018011	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	Yes	1439.02	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			Reviewed by Supervisor	05/18/2017 12:00:00 AM	ADDRESS	34.13779	-118.4138	Plan check for power and energy for 3 story parking structure, roof is soccer field and bridge connected to existing building. Total area: 315,390 sq ft.B#17010-10000-01327	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72106	14041-20001-12725	10530 W VICTORY BLVD	91606	2	177B177    90	2414019012	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM			PC Approved	08/21/2014 12:00:00 AM	ADDRESS	34.18498	-118.36061	((EXPEDITE FEES))))PV2 COMMERCIAL ROOFTOP SOLAR. TOTAL SYSTEM SIZE 30KW AC USING 3 CENTRAL INVERTERS. NONSTANDARD PLAN. INTERCONNECT TO 3PHASE 4W DELTA. 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72107	12041-20000-16507	10639 N GLENOAKS BLVD	91331	7	207B165  1053	2536015221	[T][Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			07/17/2012 12:00:00 AM	07/17/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.26264	-118.40007	Remodel existing tenant space on the first floor.  Use existing circuits to supply new and relocated or replace receptacles and lighting.  Plan check for T-24 lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72108	17041-20000-30034	6420 W WILSHIRE BLVD Suite 300	90048	5	135B173   859	5088013028	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	12/09/2017 12:00:00 AM	ADDRESS	34.06365	-118.36922	Plan check for Title 24 only. Project site is an existing tenant space within a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 13,191 sq. ft.Note: Building permit has been issued under 17016-10000-23144	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72109	19041-10000-26931	1320 W 12TH PL	90015	1	127-5A205 140	5137031029	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Issued	08/01/2019 12:00:00 AM	ADDRESS	34.04376	-118.27302	PC FOR POWER ONLY. NEW 300KW TEMPORARY GENERATOR. TEMPORARY POWER FOR FREE STANDING SIGN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72110	17041-20000-22690	10941 W OAK MOUNTAIN PL	91040	7	207B173   507	2528037015	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.26248	-118.36884	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72111	15041-20000-04792	14141 W VENTURA BLVD SUITE B	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	05/04/2015 12:00:00 AM		Permit Finaled	07/24/2015 12:00:00 AM	ADDRESS	34.14992	-118.44152	TI TO AN EXISTING COMMERCIAL BUILDING.  FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72112	11041-10001-13140	1056-1062 E ELKGROVE AVE BLDG 19	90291	11	111B145   391	4243001036	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.00222	-118.45914	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.  Variance is required to separate theFire Alarm plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72113	19041-10001-06440	445 S FIGUEROA ST 21st floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	DELTA 1 CHANGES TO AN APPROVED. CHNAGING LF1 FIXTURES FROM 2X2 FLUORESCENT TO 1X4 LED AND ADDITION OF 2 LF2 FIXTURES. Original scope: ((T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 21ST FLOOR FOR CORRIDORS AND RESTROOMS. TOTAL AFFECTED AREA IS 1968 SQ. FT. B#19016-20000-03716))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72114	15041-10000-31439	12499 W FIELDING CIR LOTS5-16	90094	11	102B161  1263	4211038038	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/22/2015 12:00:00 AM			PC Info Complete	09/22/2015 12:00:00 AM	ADDRESS	33.9784	-118.41163	PC FOR T24 ONLY. APARTMENT BUILDING HARDSCAPING. TRACT # 60110-02-REC, LOTS 5-16. TOTAL AREA 52529 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72115	16041-10000-38205	6063 E MYOSOTIS ST	90042	14	156A231   221	5486013015	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	Yes	1832.20	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.12182	-118.18685	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(18)MODULES-HANWHA Q-CELL Q PLUS G4 280(18)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72116	13041-10001-09305	19500 W PLUMMER ST G2	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	[[[[[[[[[[[SUPPLEMENTAL PLANCHECK FOR 13041-10000-09305. DELTA 1 CHANGES ONLY.  CHANGES REQUESTED BY INSPECTOR. CODE SECTION 240.4. CHANGES IN FUSES TO PROTECT THE CONDUCTORS PROPERLY]]]]]]]]]]]Buidling G improvement.  Add new branch circuits and  new two 150KVA transformer (Class 155).   Relocate 75KVA transformer in the electrical room.  Install new general/emergency lighting for tenant G-2.  All panels are existing.    Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72117	18041-20002-29051	4212 N LANKERSHIM BLVD	91602	4	165B177   892	2423024044	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Approved	11/12/2019 12:00:00 AM	ADDRESS	34.14626	-118.36314	11/12/19CHANGES TO APPROVED SET DELTA 3 ONLY. CHANGES TO LIGHTS.<<<Plan check for power and energy for T.I. of existing restaurant, Service upgrade to 600A. Total area: 4771 sq ft. B#14016-10000-15144>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72118	11041-20000-27686	17901 W TUSCAN CT	91344	12	219B129    44	2601053008	A1-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2011 12:00:00 AM	02/10/2012 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.30049	-118.52505	New 5.98 KW ground mount PV system for a single family residence.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72119	18041-10000-36670	660 S FIGUEROA ST suite 2280	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.04953	-118.25947	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. HIGH RISE. SUITE 2280.   2,115 SQ FT.BUILDING PERMIT # 18016-10000-25677	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72120	13041-10000-31381	741 N VERMONT AVE	90029	13	141B197   311	5538026023	C2-1VL	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	11/14/2013 12:00:00 AM		Permit Finaled	06/25/2015 12:00:00 AM	ADDRESS	34.08482	-118.29192	Replacement of existing fire alarm control panel with new FACP in Braille Institute.  3 additional devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72121	18041-10000-40459	3321 S LA CIENEGA BLVD	90016	10	120B173   176	4205033007	(T)(Q)C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	03/24/2022 12:00:00 AM	ADDRESS	34.0275	-118.3723	NEW FIRE ALARM SYSTEM IN A  HIGH RISE MIXED USE BUILDING.  (1) FACP    (18) REMOTE POWER SUPPLY,  (1445) FIRE ALARM DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72122	14041-20000-17521	9700 N WOODMAN AVE	91331	6	201B149   343	2644024025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.24599	-118.44723	PLAN CHECK FOR TITLE 24 ENERGY AND EMERGENCY LIGHTING.  EXISTING ONE STORY RETAIL STORE CONVERSION TO DRY CLEANER.  EXISTING CIRCUITS, NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72123	16041-10000-41260	2066 N HILLHURST AVE	90027	4	150B201   343	5590008003	C4-1D	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	04/24/2017 12:00:00 AM	ADDRESS	34.10948	-118.28726	PC for power only. Scope includes new 600 amps 120/240 single phase 3 wire. Service is for a multi-tenant space.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72124	19041-10000-12189	2112 W SUNSET BLVD J, K, L	90026	13	139-5A207 108	5402035003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1957.10	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.07733	-118.26419	PLAN CHECK FOR TITLE 24 ONLY CHANGE OF USE FROM RESTAURANT TO RETAIL. TOTAL EFFECTED AREA 2275 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72125	13041-20000-14093	601 S FIGUEROA ST Suite 4590	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.05076	-118.25881	T24 FOR HIGHRISE OFFICE SPACE SUITE 4590. SCOPE OF WORK 1570 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72126	14041-10000-24953	3508 S ENVILLE PL	90016	10	120B173   462	5047002036	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			Reviewed by Supervisor	09/23/2014 12:00:00 AM	ADDRESS	34.02288	-118.36998	PV1, INSTALL 3.315 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(13) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: POWER-ONE PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72127	19041-20000-43463	4445 N ETHEL AVE	91604	4	165B161   123	2360029028	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	12/06/2019 12:00:00 AM	ADDRESS	34.15176	-118.41827	Plan check for PV roof mounted system, PV system size: 12.240 KW DC, 11.134KW AC CEC with 34 PV Modules and 43 microinverters connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72128	13041-10002-34989	3325 N WRIGHTWOOD DR	91604	2	159B173   399	2380014039	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2013 12:00:00 AM			PC Approved	12/26/2013 12:00:00 AM	ADDRESS	34.13194	-118.37495	CHANGE OF LAYOUT OF ROOF-MOUNTED SOLAR SYSTEM ON THE ROOF.{{PV1, ROOF-MOUNTED SOLAR ARRAY INTERCONNECTING WITH (E) 200A MAIN SERVICE. SYSTEM SIZE IS 6.048 kW AC, 6.3kW DC. ENPHASE M215 MICROINVERTER ON STANDARD PLAN, WITH 28 MODULES (WATTON WTM225 ), (1) 60A LOAD CENTER.}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72129	16041-20000-18102	1201 W 5TH ST 1st Floor	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			05/23/2016 12:00:00 AM	01/19/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.05429	-118.25967	TI to (E) commercial production studio and associated spaces.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72130	18041-20000-44179	6600 N TOPANGA CANYON BLVD #2050	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			11/19/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI OF AN EXISTING SPACE FROM RETAIL TO A RESEARCH AND OFFICE SPACE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 2464 SQ.FT. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72131	12041-20000-26581	10739 W ACAMA ST	91602	4	165B177   909	2423026007	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2012 12:00:00 AM	12/04/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.146	-118.36461	PV-1. Plan check for PV system. Single family dwelling. Micro inverters, 8.8kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72132	12041-10001-01624	8378 W MELROSE AVE 2nd flr-3rd flr	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM			PC Approved	02/09/2012 12:00:00 AM	ADDRESS	34.08341	-118.37285	T.I. to an existing 3-story office building.  No emergency lighting.  PLAN CHECK ONLY for Energy on the 2nd and 3rd floor, (No suite number per applicant)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72133	15041-10000-24831	1125 S BOYLE AVE	90023	14	123A221   272	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.03064	-118.22048	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHTING FIXTURES AND RPLACE WITH LED LIGHITNG FIXTURES. PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72134	14041-20000-36069	11601 W WILSHIRE BLVD # 2060	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	PIN	34.0509267	-118.45996763	Energy plan check only.  TI to existing office space. Adding lighting and emergency. 1312 Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72135	18041-20000-13406	13415 W ERWIN ST	91401	2	177B157   372	2330005023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.18315	-118.42522	PC for 7.6kW(ac)/9.735kW(dc) rooftop solar for SFD with 5kW back-up battey . Installing 33 modules with optimizers, multimode inverer, backup panels and 5kW back up battery.$24.03 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72136	15041-20000-29488	301 N WESTLAKE AVE	90026	13	136-5A205 403	5157025038	R4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Expired	09/10/2023 12:00:00 AM	ADDRESS	34.06887	-118.26727	pv1. roofmounted solar system. system size 4600w.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72137	15041-20000-41064	1064 S GAYLEY AVE	90024	5	132B149    76	4363024019	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			12/07/2015 12:00:00 AM			PC Info Complete	12/07/2015 12:00:00 AM	ADDRESS	34.06094	-118.44687	TENANT IMPROVEMENT EXISTING RESTAURANT SPACE. PC FOR ENERGY ONLY. TOTAL AREA 1,650 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72138	11041-10000-19103	624 S GRAND AVE 1220	90014	9	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Finaled	09/30/2011 12:00:00 AM	PIN	34.04778206	-118.25563275	TI TO AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK ONLY FOR ENERGY, NO EMERGENCY LIGHTING PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72139	13041-20000-17194	16910 W SATICOY ST	91406	6	186B133   281	2203014018	C2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Commercial			06/28/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	PIN	34.20806009	-118.50155365	NEW ONE STORY, TYPE VB  RETAIL SPACE.  Service is 200 amps.  PLAN CHECK ONLY for Energy only, NO Emergency lighting per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72140	10041-10000-20444	6301 W 3RD ST	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM	12/29/2010 12:00:00 AM		Permit Finaled	02/18/2011 12:00:00 AM	ADDRESS	34.07243	-118.35963	NEW RCEPTACLES/BRANCH CIRCUITS AND EXTERIOR LUMINAIRES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72141	15041-10000-18332	4211 N BARRYKNOLL DR	90065	1	154-5A219 211	5472010012	R1-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1862.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM			Corrections Issued	06/29/2015 12:00:00 AM	ADDRESS	34.11779	-118.22234	PV1 5kw roof-mounted system with (20) Kyocera KU2656 modules and (1) ABB PVI-5000 inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72142	17041-10000-34447	4425 S CENTRAL AVE	90011	9	112-5A209 121	5108028030	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.00306	-118.25677	PC for T24 only for replacement of existing fixtreswith LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72143	12041-20000-02328	9420 N RESEDA BLVD #4	91324	12	198B125   131	2764010041	(Q)C2-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			02/01/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	04/12/2012 12:00:00 AM	ADDRESS	34.24152	-118.53589	T24 lighting plan check for TENANT IMPROVEMENT TO (E) 1-STORY RESTAURANT (UNIT #4), ALL WORK IS INTERIOR AND NON STRUCTURAL.  (SEE COMMENTS)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72144	12041-20000-30718	19300 W RINALDI ST SUITE H	91326	12	210B117    24	2822019013	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			12/20/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.27414	-118.55457	Plan check for energy and emergency lighting. 905 sqft. suite H.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72145	14041-10000-32354	6316 N TOPANGA CANYON BLVD Building B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.18578	-118.60514	Power plan check for new electrical equipment related to outdoor lighting systems for common area of Westfield Topanga outdoor mall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72146	16041-20000-36512	9741 N NITA AVE	91311	12	201B101   285	2727007006	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.24773	-118.61394	PV1- INSTALL PV 26 MODULES 6.5kW. (microinverter).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72147	14041-20000-35557	12871 W WEIDNER ST	91331	7	213B161   582	2533024012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	01/06/2015 12:00:00 AM	ADDRESS	34.27981	-118.41339	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.87 KW(1) SMASB5000 INVERTER(16) SUNPOWER SPR-X21	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72148	18041-30000-47313	16133 W VENTURA BLVD 1st Floor	91436	5	168B141   471	2260023018	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			12/13/2018 12:00:00 AM	01/29/2019 12:00:00 AM		Issued	01/29/2019 12:00:00 AM	ADDRESS	34.15675	-118.4847	Plan check for Title 24 only. Project site is a tenant space in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,215 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72149	15041-20000-30065	1249 S BUNDY DR 1-18	90025	11	126B145   321	4263002022	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Apartment			09/11/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.04292	-118.46644	Plan check for a PV2 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72150	19041-10000-10699	1515 W 190TH ST ste. 417	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	PC for TI, T-24 only, 1685 SF of total floor area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72151	19041-10000-12757	13130 W BURBANK BLVD	91401	4	174B157  1137	2345005028	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.17191	-118.41936	Replace fluorescent troffers with new LED retrofit kits in BLD#3  Indoor only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72152	14041-10007-16201	950 E 3RD ST	90013	14	127-5A217  91	5163016012	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Apartment			01/29/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.04578	-118.23334	THIS IS PLAN CHECK FOR DELTA 14 ONLY; CHANGES TO THE APPROVED DELTA 7 & 13. REVISE FEW LOADS BASED ON FIELD CHANGES, REVISE TYPE OF LUMINAIRES AND REVISE T24 FORMS AND LIGHTING FLOOR PLANS ACCORDINGLY.  THIS IS SUPPLEMENTAL PLAN CHECK ONLY, PERMIT IS STILL COVERED UNDER MASTER.<<<<<PLANCHECK FOR POWER AND ENERGY FOR  A  NEW 472 Unit Type III  Apt. Building Over Type I Commerciasl Use & Garage Structure. TITLE 24 ENERGY SQFT NOT INCLUDED IN FEES. FEES ARE BASED APPLICANT.>>>>	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72153	18041-20000-25775	1999 S AVENUE OF THE STARS Suite 3350	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only. Project site is a suite in an existing building. Project scope is a tenant improvement. Total lighting area = 1,911 sq. ft.Note: Building application has been generated under	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72154	11041-10000-03198	1100 W WILSHIRE BLVD	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	08/15/2011 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.05228	-118.26384	TENANT IMPROVEMENT, NEW USE AS A MEDICAL OFFICE.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72155	13041-10000-32057	140 E HURRICANE ST	90292	11	103-5A147 272	4225010900	RW1-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM			Verifications in Progress	04/17/2014 12:00:00 AM	ADDRESS	33.97589	-118.46122	Install three valve actuators, and one flow meter for waste water pump plant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72156	15041-20001-09718	7326 N RESEDA BLVD	91335	3	186B125   788	2119019032	[Q]C2-2D-CDO, [Q]P-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			08/03/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Permit Finaled	03/09/2016 12:00:00 AM	ADDRESS	34.20379	-118.53585	Changes to approved set.  Revised floor plan, vacuum area and toll booth added, and DWP transformer and main switchboard relocated.  All changes clouded with delta 1.*****Previous work description*****Plan check for pwer and Title-24 (energy).  Total area = 2,474 sq. ft. (indoor) + 22,590 sq. ft. (outdoor)New 1000 A service and electrical distribution system for carwash.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72157	19041-10000-10683	1515 W 190TH ST ste. 410	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	PC for TI work T-24 only. 1578 SF of total floor area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72158	18041-10000-33933	24910 S AVALON BLVD	90744	15	039B205   627	7404024045	[Q]C1-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.79976	-118.26375	REPLACE INDOOR-OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72159	16041-10001-00730	717 W OLYMPIC BLVD STE 105	90015	14	127-5A207 342	5138002***	C2-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM			PC Approved	05/10/2016 12:00:00 AM	ADDRESS	34.04503	-118.26348	RECHECKING FOR T24 FOR CONNECTING EMERGENCY CIRCUITS.EGRESS LIGHTING TO CONNECT TO EMERGENCY GENERATOR CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72160	19041-20000-26599	5340 N CREBS AVE pv1	91356	3	171B121   143	2161004027	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.16759	-118.54428	pv1install roof mounted pv system sized 12.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72161	13041-10000-23950	1743 S SHERBOURNE DR	90035	5	129B169  1289	4303016038	R1-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	02/11/2014 12:00:00 AM	ADDRESS	34.04673	-118.38081	PV1 ROOF MOUNTED SOLAR INSTALLATION USING THE MICROINVERTTER STANDARD PLAN. [MICROINVERTER:  ENPHASE # M215 |||| MODULES: SUNMODULE # SW265] SYSTEM SIZE IS 2.808 KW AC AND 3.445 KW DC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72162	14041-10000-33729	4521 W STANTON DR	90065	14	160-5A219 132	5683040004	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.13473	-118.22673	PV1.  Install 9.945 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan. FEE AMOUNT REFLECT ON SENATE 1222.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72163	13041-20000-17901	3330 N CAHUENGA BLVD WEST SUITE 300	90068	4	159B181   395	2425001063	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			07/08/2013 12:00:00 AM			PC Approved	07/08/2013 12:00:00 AM	ADDRESS	34.13099	-118.35061	TI FOR EXISTING NON HIGHRISE OFFICE SPACE. THIS PLAN CHECK IS FOR SUITE 300. TOTAL SQRFT: 871	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72164	14041-20002-14572	4458 N WESTCHESTER DR	91364	3	166-5A111  38	2174013027	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2014 12:00:00 AM			PC Approved	07/25/2014 12:00:00 AM	ADDRESS	34.15172	-118.5836	Changes from previously approved plans.  Change in modul arrangement on roof top and single line diagram.Note: Permit is under the original application.  Plan check fee $0.00 due to Senate Bill 1222 from 2012*****Previous Description*****Roof mounted PV system.  Total system size 17KWdc.Note: Permit fee $0.00 due to Senate Bill 1222 from 2012.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72165	16041-10002-39332	2340 S FAIRFAX AVE	90016	10	123B173   148	5064024011	[Q]CM-1VL, [Q]P-1, [Q]P-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2703.00	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.0365	-118.3687	CHANGES TO APPROVED SET OF PLAN. (2 SHEETS AFFECTED) - SCOPE INCLUDES ADDITION OF NEW KTCHEN EQUIPMENTS AND RECEPTACELS ON PANEL RP17 TOTAL LOAD CHANGE APPROX 12A OF ADDED LOAD. CHANGES UNDER DELTA 15ORIGINAL PLAN CHECK - 16041-10000-39332PC FOR POWER AND ENERGY for a service upgrade to 1600 amps 480/277V 3phase for wire. New equipment and circuits also added. Total sqft is  123,977	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72166	16041-10000-41218	9200 N GLENOAKS BLVD	91352	6	198B173   111	2408001003	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.2363	-118.37296	PC FOR LIGHTING FIXTURE REPLACEMENT FOR PARKING LOT. PC FOR T24 ENERGY ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72167	18041-20002-28730	2732 W LOCKSLEY PL	90039	4	151-5A207 185	5438018021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	ADDRESS	34.10749	-118.26237	Revision to approved set.  Change of module power rating from 320W to 315W.  update System size: 7.56KW$0 fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72168	14041-10000-08963	21820 W NORDHOFF ST	91311	3	195B105     4	2779020052	QMR1-1, QP-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/18/2014 12:00:00 AM	ADDRESS	34.23524	-118.60364	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72169	16041-10001-29429	1746 N CHEROKEE AVE	90028	13	148-5A185  13	5547004012	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			08/18/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.10294	-118.33462	Expedited rses plan check per applicant request.<<<PV, install a 58.23 kw dc roof-mounted solar array on a apartment building. (191) modules:q. pro L-G2 305-315(3) inverters: sma sb10000tl-us 10 kw and (2) inverters: symo  Fronius 10.0-3>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72170	14041-20000-31692	15558 W PLUMMER ST	91343	7	198B145    49	2656015017	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	02/09/2015 12:00:00 AM	ADDRESS	34.24262	-118.47164	10kw ac PV system. using 28 modules. nonstandard plan. derate main breaker	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72171	15041-10000-38360	12017 W VOSE ST	91605	2	183B165   111	2321003034	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.39489	REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72172	17041-10000-26058	21415 W PLUMMER ST	91311	12	201B105   244	2746015022	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.24287	-118.59861	TITLE 24 PLAN CHECL FOR TI (CHANGE OF USE OF CHILD CARE FACILITY TO OFFICE 6,668 SQFT ON 1ST FLOOR OF EXISTING 2-STORY BLDG)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72173	17041-10001-41512	700 S FLOWER ST G620	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Issued	01/30/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Supplemental for changes to approved set. Connecting em lights to em panel and adding six receptacles circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72174	16041-10000-01522	15797 W COBALT ST	91342	7	222B141   244	2604009031	RA-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	06/08/2016 12:00:00 AM	ADDRESS	34.30244	-118.47508	PV1, ROOF MOUNTED SOLAR SYSTEM, (38) MODLUES WITH (2) 6KW INVERTERS. TOTAL SIZE: 12KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72175	13041-10000-32069	138 N BEAUDRY AVE 101-106	90012	1	133-5A211 129	5160030015	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Apartment			11/15/2013 12:00:00 AM	11/19/2013 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.06001	-118.2534	PLAN CHECK AND PERMIT FOR ADDITION OF NOTIFICATION APPLIACES TO NEW RESIDENTIAL UNITS IN EXISTIN BUILDING TO EXISTING FIRE ALARM SYSTEM. 1 BOOSTER PANEL WITH POWER SUPPLY AND 6 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72176	14041-10000-29081	6745 N FALLBROOK AVE SPACE 916	91307	12	180B097    24	2038040027	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.19253	-118.62413	TI to (E) 6529 sq ft commercial retail space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72177	19041-20001-07527	431 N PASEO MIRAMAR	90272	11	126B117    20	4416001026	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	34.04528	-118.55525	5/28/2019changes to an approved set of plans.  changes to replace modules to LG 340Watts.this is plan check only.  PV1.  Install 31.35 kW DC / 22.8 kW AC and consists of (95) modules, (95) micro-inverters, and (1) load center.$0 permit fee per State Senate Bill SB 1222.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72178	16041-10000-28548	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/24/2016 12:00:00 AM	12/14/2018 12:00:00 AM		Permit Finaled	08/07/2020 12:00:00 AM	ADDRESS	34.16935	-118.53104	NEW 7 STORY, LOW RISE PARKING STRUCTURE. FULL PC FOR POWER AND ENERGY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72179	16041-10000-32293	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			09/12/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.05855	-118.23671	FULL PC FOR POWER AND ENERGY.  REMODELING OF EXISTING COMPUTER ROOM 6TH ON THE  THIRD FLOOR OF EXISTING DATA CENTER.  SCOPE INCLUDE FOUR NEW PDUs, NEW 600A DISTRIBUTION BOARDS, AND NEW HVAC EQUIPMENT. TOTAL AFFECTED AREA IS 3623 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72180	17041-20001-13555	1990 S BUNDY DR	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM			PC Approved	06/27/2017 12:00:00 AM	ADDRESS	34.03419	-118.45559	Revisions to original approved set.  Address added to plan set, slight revision to lighting system.  Approval is for clouded items only.  (((PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 4189 SQFT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72181	14041-10000-00627	10418 W PENROSE ST	91352	7	195B177   247	2404002016	RA-1-K	North Valley		Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.23206	-118.35781	PV1. ROOF MOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE. 9.072 KW AC. (42) E & H CO LTD EHS3 - 250(42) ENPHASE 215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72182	16041-20000-21445	535 S KINGSLEY DR (1-72)	90020	10	135B193   769	5503023019	(T)(Q)R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			06/17/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	01/11/2018 12:00:00 AM	ADDRESS	34.06428	-118.30317	INSTALLATION OF A NEW FIREALARM SYSTEM. 1 FACP AND 284 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72183	19041-20000-18108	20835 W PINECONE CIR 22	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.29591	-118.58811	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72184	11041-20000-05577	300 S GRAND AVE 5th Floor	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			03/22/2011 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to a high rise building.  Install general lighting in partial of 5th floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72185	18041-20000-25872	5244 N LEMONA AVE	91411	4	172-5A147 208	2250021028	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	07/26/2018 12:00:00 AM	ADDRESS	34.16616	-118.45944	PV1.  Install 8.82 kW roof mounted grid tied PV system. (28) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72186	12041-10000-02167	17420 W DORIC ST	91344	12	222B129    16	2601020048	RE11-1-H-K, RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2012 12:00:00 AM	03/06/2012 12:00:00 AM		Permit Finaled	06/18/2012 12:00:00 AM	ADDRESS	34.30632	-118.51389	PLAN CHECK 9.16KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72187	17041-10000-41087	12680 W FOOTHILL BLVD	91342	7	216B161    94	2514005050	P-1VL-CUGU, [Q]C2-1VL-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.28982	-118.41168	REPL;ACING OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72188	17041-30000-27863	6333 W 3RD ST Unit 130	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			08/08/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	01/02/2018 12:00:00 AM	ADDRESS	34.07157	-118.36014	Plan check for Title 24 only in existing space restaurants T.I. Total area: 685 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72189	17041-20000-42643	10580 W STALLION RANCH ROAD	91040	7	204B173   495	2542007***	A1-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.25709	-118.36008	PV1.  Install roof mounted pv system sized 20kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72190	16041-10001-28376	811 W WILSHIRE BLVD FLR 3	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/01/2017 12:00:00 AM			PC Approved	02/01/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	02/01/17CHANGES TO AN APPROVED SET OF PLANS. REPLACING LIGHING FIXTURES IN THE CORRIDORS, AND KEEPING EXISTING LIGHTS FOR THE OFFICE SPACES, REVISING TITLE 24 CALCULATIONS.  AFFECTED AREA IS CHANGED FROM  14070 SQ. FT TO 885 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72191	14041-10000-20589	1740 N RIAL LANE	90077	5	147B149    66	4371003011	RE40-1, RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2014 12:00:00 AM			PC Info Complete	01/23/2015 12:00:00 AM	ADDRESS	34.10259	-118.44812	plan check for power and energy (per 2008 standards. Single family dwelling. 4 stories. 600A service. not methane. with optional standby generator.  BLDG#07014-10005-07788.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72192	17041-20000-03680	9810 N ZELZAH AVE	91325	12	201B129   126	2755001019	(Q)R3-1	North Valley	Northridge	Northridge East		1151.04	Electrical	Electrical	Apartment			02/03/2017 12:00:00 AM			Reviewed by Supervisor	03/13/2017 12:00:00 AM	ADDRESS	34.24898	-118.52309	PV2.  Feed-in-tariff project. Install 542 kW AC roof mounted grid tied PV system.  (1890) modules with multiple inverters of varying ratings.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72193	14041-20001-10232	655 S HOPE ST #101	90017	14	129A209   262	5144006901	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Info Complete	11/21/2014 12:00:00 AM	ADDRESS	34.04849	-118.25759	Change from previously approved plans.  Change in lighting and minor change in branch circuits.  Plan check for power and energy.*****Previous Description*****Remodel for new restaurant on ground floor of existing commercial highrise building.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72194	18041-20001-03167	6033 W CENTURY BLVD 150	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	33.94572	-118.38954	02/15/2018 Plan check for Title 24 only. Project site is a suite on the ground floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 5,052 sq. ft.Note: Building application has been generated under 17016-10000-35210*****Previous Work Description*****New outlets and furniture feeds.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72195	15041-10000-24126	1940 S CENTURY PARK EAST	90067	5	132B161    17	4319001007	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.06073	-118.41375	NEW FA SYSTEM FOR (4) STORY COMMERCIAL BLDG. (1)FIRE ALARM CONTROL PANEL (167) FIRE ALARM DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72196	17041-10000-42398	9113 S WESTERN AVE	90047	8	094-5A193  81	6036016030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			11/22/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	12/11/2017 12:00:00 AM	ADDRESS	33.95412	-118.3092	PC FOR NEW FA. SCOPE INCULDES 21 DEVICES AND ONE PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72197	15041-20000-08753	7208 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.24848	-118.28894	Plan check for Title 24 only. Project scope is a tenant improvement to a new commercial space (first time tenant; approved for counter plan check by E.M.). Total lighting area = 1,092 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72198	11041-20000-16120	4444 N LANKERSHIM BLVD 104-105	91602	4	165B173   162	2423005011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	08/02/2011 12:00:00 AM		Permit Finaled	09/22/2011 12:00:00 AM	ADDRESS	34.15169	-118.36642	PLAN CHECK POWER AND ENERGY ON 1ST FLOOR ACUPUNCTURE  MEDICAL CLINIC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72199	18041-10000-42783	9030 W NATIONAL BLVD	90034	5	123B169  1166	4311029014	C2-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	ADDRESS	34.03112	-118.39185	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72200	10041-10000-07879	3255 W WILSHIRE BLVD #100 & 110	90010	10	135B197  1185	5502026020	C2-2, C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM			PC Info Complete	04/29/2010 12:00:00 AM	ADDRESS	34.06195	-118.29324	TI IN AN EXISTING COMMERCIAL AREA IN SUITE # 100 & 110. PLAN CHECK IS FOR TITLE 24 AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72201	14041-20001-00777	13749 N KISMET AVE	91342	7	228B153   314	2503004013	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.32186	-118.43458	$0 PLAN CHECK FEE DUE TO SENATE BILL 1222 FROM 2012CHANGE IN DESIGN. NOW16 MODULES TOTAL. 3.4KW SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72202	15041-20000-23488	12115 W BLUFF CREEK DR	90094	11	105B165   936	4211010103	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	12/07/2015 12:00:00 AM	ADDRESS	33.97884	-118.4045	Plan check for Title 24 only in existing building. Total indoor area: 13,049sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72203	18041-20000-11488	5659 1/2 E HUNTINGTON DR NORT	90032	14	147A239   344	5309027026	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	PIN	34.0969759	-118.15687406	pv1install roof mounted pv system sized 5.4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72204	11041-10000-21489	600 W 7TH ST	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	New fire alarm panel and devices for fire supression system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72205	16041-20000-07807	9415 N RUFFNER AVE	91343	12	198B137   165	2687014023	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2016 12:00:00 AM	03/04/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.24209	-118.49724	PV1.  Install 10.7 kW roof-mounted PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72206	17041-20000-24264	6600 N TOPANGA CANYON BLVD #9219	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	energy check for new kiosk.  total square footage 321.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72207	19041-20002-28143	3860 S 3RD AVE pv1	90008	10	117B189  1008	5034017047	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2340.00	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM			PC Approved	08/19/2019 12:00:00 AM	ADDRESS	34.01608	-118.32022	Revisions to approved plans.  Revised locations of AC disconnect and 125A sub panel. $0 plan check fee per State Senate Bill SB 1222 and Assembly Bill AB 1414.(((pv1install roof mounted pv system sized 5KW AC interconnected with msp.this is an addition to an existing system.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72208	18041-20000-45737	13907 W COHASSET ST pv1	91405	2	186B153   114	2215005016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/03/2018 12:00:00 AM		Permit Finaled	12/24/2018 12:00:00 AM	ADDRESS	34.20676	-118.43604	pv1install roof mounted pv system sized 6KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72209	18041-20001-18371	1070 S HOLT AVE 1-29	90035	5	132B173   618	4332025020	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			06/26/2019 12:00:00 AM			Corrections Issued	07/08/2019 12:00:00 AM	ADDRESS	34.05732	-118.37817	Revision to approved plans.  Change of service conductor wiring detail.  (((Plan check for power and energy. Project site is a new 5-story, 29-unit apartment building. Total lighting area = 23,281 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72210	13041-10000-08857	20845 W SAN JOSE ST	91311	12	207B109   698	2706012015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	10/11/2013 12:00:00 AM	ADDRESS	34.261	-118.58815	PV1 SINGLE FAMILY DWELLING. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. TRANSFORMERLESS INVERTERS. SYSTEM SIZE: 6.615 kW. 27 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72211	11041-20000-17745	14761 W CALIFA ST	91411	2	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			08/22/2011 12:00:00 AM	08/22/2011 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.17768	-118.45503	T24 Energy & Emergency plan check for new restrooms and lunch room for existing building. Permit for new ckt and work on existing ckts	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72212	18041-10001-42301	15976 W ALCIMA AVE	90272	11	129B125   261	4420003017	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	34.05093	-118.53477	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72213	13041-10000-00807	1127 W WILSHIRE BLVD	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			01/11/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.05287	-118.26415	Surgical center - power and energy.  Change of occupancy from a B occupancy to an I-2.1.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72214	10041-10000-13346	1248 S FIGUEROA ST	90015	9	126A205    19	5138025014	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Public Safety Only			07/13/2010 12:00:00 AM	07/13/2010 12:00:00 AM		Permit Finaled	04/07/2011 12:00:00 AM	ADDRESS	34.04096	-118.2674	NEW FIRE WARNING SYSTEM FOR A 2-STORIES BUILDING WITH A RESTAURANT AND 2 EA RETAIL STORE ON THE FIRST FLOOR AND A RESTAURANT/CLUB ON THE SECOND FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72215	14041-10000-07942	9270 N NAGLE AVE	91331	6	198B153   664	2642023020	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM	04/29/2014 12:00:00 AM		Permit Finaled	05/07/2014 12:00:00 AM	ADDRESS	34.23876	-118.43569	PV1,INSTALL 3.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.WITH POWER OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3000A-US-ZB-U(13) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72216	13041-10001-14023	380 WORLD WAY Space T51B	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	changes to approved set of plans: ASBUILT to show that 208V panel + transformer moved from 277/480V to 208 distribution board (now without transformer). Original Description: pc for power and energy. retail STORE FRONT ONLY (Starbucks).  1st time TENANT IMPROVEMENT in LAX (Space T51B).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72217	18041-20000-48116	2580 W VENICE BLVD	90019	10	126B189   294	5073023028	C2-1VL	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	06/29/2020 12:00:00 AM		Permit Finaled	12/07/2021 12:00:00 AM	ADDRESS	34.04336	-118.31705	1600A 208Y/120V 3ph-4w service, distribution, power and lighting for new core and shell building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72218	15041-10001-43492	357 N FORDYCE ROAD	90049	11	138B141   395	4429019033	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM			PC Approved	01/29/2016 12:00:00 AM	ADDRESS	34.07266	-118.47174	1/29/16CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDE THE CHANGE OF REQUIRED OCPD AND DOWNSIZE WIRE SIZE TO A #6 AFTER THE LOAD CENTER. TERMINATION RATING ARE RATED AT 75*C.(((PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC. 52 MODULES AND 2 INVERTERS)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72219	10041-20000-10833	600 W 7TH ST #150	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	12/09/2010 12:00:00 AM	ADDRESS	34.04728	-118.25685	Plan check T-24 Energy general/emergency lighting for Sugarfish Sushi Bar suite #105 in high-rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72220	19041-10000-34186	22816 W MARLIN PL	91307	12	183B097   522	2026022010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.19669	-118.6241	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 28 MODULES USING P400 OPTIMIZERS WITH 2 ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72221	14041-10000-03880	4143 N BELLINGHAM AVE	91604	2	165B165  1046	2367013041	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	07/18/2014 12:00:00 AM	ADDRESS	34.14622	-118.39882	PV1. ROOFMOUNTED SOLAR SYSTEM WITH TRANSFORMERLESS INVERTER. TWO STORY. SYSTEM SIZE: 5.30 KW DC.(20) SUNIVA # OPT265 (1) POWER-ONE AURORA PV1-5000	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72222	17041-10000-39194	340 N WESTERN AVE	90004	10	138B193   245	5521027018	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM			PC Approved	10/30/2017 12:00:00 AM	ADDRESS	34.07736	-118.30892	T-24, PC FOR LIGHTING ONLY ON A FIRE DAMAGE BUILDING, SCOPE OF WORK INCLUDE NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1555.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72223	10041-10000-09537	7000 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	05/27/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	PIN	33.93847109	-118.41935625	Ti in AA airline support rooms. Plan check for T24 and Energy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72224	17041-10000-09563	2000 S LINCOLN BLVD	90291	11	108B149   104	4242003011	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM			Corrections Issued	03/24/2017 12:00:00 AM	ADDRESS	33.99575	-118.45581	TI AND FACADE REMODELING AND REDESIGN, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES WITH OUTDOOR LIGHTING. TOTAL SQ. FT.1600	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72225	13041-10001-33755	541 S SPRING ST STE # 101	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM			PC Approved	07/07/2014 12:00:00 AM	ADDRESS	34.04657	-118.2507	CHANGES TO APPROVED SET PER INSPECTORS REQUEST. PLANCHECK FOR T24 ENERGY. T.I. - UNIT 101  - 1,048SF, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72226	13041-10000-35582	9700 W SOMBRA TER	91040	7	201B181    55	2545006017	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2013 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.25115	-118.342	PV1, Install 3 kW DC roof-mounted solar array for a  house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (12) modules: Rensola Solar JC250M-24/BB.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72227	15041-20000-14052	7331 W VALMONT ST	91042	7	204B197  1067	2558022009	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	08/16/2022 12:00:00 AM	ADDRESS	34.25242	-118.29217	Plan check for Fire alarm system. Total number of device:23	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72228	16041-10000-44291	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	"PLAN CHECK FOR T24 ONLY.ALTERATIONS MADE TO EXISTING PERMIT UNDER 15041-10001-29087. ALL WORK TO BE DONE BY NEW CONTRACTOR FOR THIS PORTION ON PROJECT. INSTALLING NEW LIGHTS AND RECEPTACLES. ALL NEW WORK TO BE CLOUDED UNDER ""lIMIT OF WORK""(SEE PG EL01.41 OF PLANS). TOTAL AFFECTED AREA IS 3155 SQFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72229	17041-30000-35441	10100 W SANTA MONICA BLVD Suite 430	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for Title 24 only in existing space high rise building 4th floor suite 430. Total area: 3375 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72230	13041-10000-09256	727 S BURLINGAME AVE	90049	11	126B141   195	4264007005	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2013 12:00:00 AM	05/01/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.04347	-118.48283	PV1 FOR 2 STORY SINGLE FAMILY DWELLING. 28 MODULES AND 2 INVERTERS. TRANSFORMERLESS SYSTEM. [INVERTER: SUNPOWER SPR-4200P-TL-1] [SOLAR MODULE: SUNPOWER SPR-327NE-WHT-D]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72231	17041-20000-03621	1800 N HIGHLAND AVE	90028	13	150A185   305	5547001023	[Q]R5-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.10436	-118.33763	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR INDOOR AND OUTDOOR LIGHTING. 5655 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72232	19041-20000-37546	6300 N CANOGA AVE STE 1530W	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	12/12/2019 12:00:00 AM	ADDRESS	34.18492	-118.59722	Tenant improvement to (E) office P.C for title-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72233	18041-20000-12531	5555 W MELROSE AVE Stage 3	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	06/10/2019 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for power service replacement for 1200A  to new equipment and reconfigured location of service equipment. Exinsting load to remain	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72234	15041-20000-30740	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM			PC Approved	11/24/2015 12:00:00 AM	ADDRESS	34.08363	-118.32191	Title 24 plan check only.  Total area = 4,214 sq. ft.    T.I. to existing commercial office space.  New lighting, receptacles, and AHU.  Less than 400 A new load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72235	17041-10000-37845	9861 N RESEDA BLVD	91324	12	201B125    97	2763037900	[Q]PF-1XL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.24963	-118.53631	TITLE 24 ONLY, RELACE OUTDOOR EXISTNG FIXURES WITH LED FIXURES, TOTAL SQUARE FOOTAGE 11675 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72236	14041-10000-02166	1840 S CENTURY PARK EAST 4TH & 7TH-FLR	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			PC Approved	01/24/2014 12:00:00 AM	ADDRESS	34.06188	-118.41473	T24 PART 6 ENERGY PLAN CHECK ONLY FOR 495 SQ FT RESTROOMS IN HIGH-RISE BUILDING. WORK WILL BE PERFORMED ON 4TH AND 7TH FLOOR, WITH EMERGENCY LIGHTING FED VIA (E) EMERGENCY CKT. SCOPE OF WORK < 400A. PERMIT IS EXISTING PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72237	14041-20000-35742	13401 W RIVERSIDE DR Bld. 3C	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			12/29/2014 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	05/21/2021 12:00:00 AM	ADDRESS	34.15778	-118.42471	New 3 story building with 27 units.  New 1200A service, panels, and branch circuits.  Plan check for power only.Note: variance to separate fire alarm plans submitted on 12/29/14.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72238	08041-20004-27455	10811 W SHERMAN WAY Rama bldg.	91352	2	183B173    87	2410019038	[Q]M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	Commercial			04/20/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	06/28/2011 12:00:00 AM	ADDRESS	34.20138	-118.36621	Revisions to approved P/check under PCIS 08041-20000-27455. Deleted (4) panelboards and (1) 30 KVA Tfr, added (2) panelboards and (1) 75 KVA Tfr.(Tenant improvement , original shell building 09041-20000-08805)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72239	19041-10000-30667	3200 W TEMPLE ST	90026	13	139-5A201 270	5156006002	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	10/30/2020 12:00:00 AM		Permit Finaled	11/29/2022 12:00:00 AM	ADDRESS	34.07517	-118.28141	(Fee Estimate)FULL PC POWER AND ENERGY FOR A NEW MIXED USE BUILDING. 5 STORY WITH 64 UNIT. 3000A SERVICE 208/120V, 3PH,4WIRE. AREA OF SCOPE 8,191.5SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72240	19041-20000-42524	2024 N BENEDICT CANYON DR	90210	5	150B153   501	4383012014	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.10756	-118.43621	Plan check for PV roof mounted system, PV system size: 10.95KW DC, 9.96KW AC CEC with 30 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72241	11041-20000-25699	3415 S SEPULVEDA BLVD #205	90034	5	117B157    16	4251015008	C2-1, C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM			PC Approved	12/02/2011 12:00:00 AM	ADDRESS	34.02055	-118.42347	suite #205 office t.i.T24 Energy , emergencyFire / Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72242	17041-20001-36600	4537 N CEDROS AVE	91403	4	168A149   154	2265001239	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.15412	-118.45319	EXPEDITED PER APPLICANTS REQUEST.INSTALLATION OF BATTERY STORAGE SYSTEM + PV1. ROOFMOUNTED SOLAR SYSTEM.SYSTEM SIZE :  0.5 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72243	18041-20000-16090	5916 N FIGUEROA ST	90042	1	151-5A229 114	5492015028	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	06/14/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.1106	-118.19037	Plan check for Title 24 only in existing space T.I. new lighting receptacles for existing service. Total area: 936 sq ft. B#18016-10000-08778	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72244	12041-10000-23714	4426 N LANKERSHIM BLVD	91602	4	165B177   259	2423006001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM			PC Approved	10/04/2012 12:00:00 AM	ADDRESS	34.15108	-118.36604	remodel a Hwertz car rental officesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72245	18041-20001-36419	17236 W ELKWOOD ST	91406	6	189B133   713	2204013014	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2018 12:00:00 AM			PC Approved	10/12/2018 12:00:00 AM	ADDRESS	34.21266	-118.509	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 12.95 kWdc/15.2 kWac and consists of (2) inverters, (37) modules, (2) batteries, (2) load centers, and (1) transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72246	17041-10000-09499	10049 N CANOGA AVE	91311	12	204B105   669	2747010029	[T][Q]CM-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.25325	-118.59748	PC for energy only, outdoor only. Removing HID fixtures and replacing them with new LEDs for outdoor use. Area: 24,500.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72247	13041-20002-22744	1946 S WESTHOLME AVE PV-1	90025	5	129B157   385	4317005012	R1-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2013 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.05146	-118.42717	PV-1. Plan check due to 50A branch circuit. ONe 6.5kW inverter and one 2.5kW inverter for 9kW AC. ((SUPPLEMENTAL APPLICATION TO REFLECT AS BUILT))) DUE TO SOLAR FEE CAP, NO CHARGE DUE. FEES ARE CORRECT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72248	15041-20000-00090	11938 W RUNNYMEDE ST UNIT A	91605	2	186B165   486	2317014018	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2015 12:00:00 AM			PC Approved	01/02/2015 12:00:00 AM	ADDRESS	34.20563	-118.39354	Revisions to an approved set of plans. Relocation of the AC disconnect and PV meter from South facing wall to West facing wall. Reference application number: 14041-20000-31862	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72249	18041-10000-35599	10000 W PICO BLVD	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM			PC Approved	09/18/2018 12:00:00 AM	ADDRESS	34.05211	-118.40654	TI IN AN EXISTING BAR / LAOUNG. T-24 ENERGY ONLY.BLGD PERMIT: 18016-10000-10469	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72250	17041-20000-18658	8532 N HASKELL AVE	91343	12	192B141   155	2673011057	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.22566	-118.47624	pv1install roof mounted pv system sized 5.2kw interconnected with msp with battery back up.AC coupled system	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72251	15041-10005-39684	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/27/2017 12:00:00 AM			PC Approved	02/27/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	02/27/17Changes to an approved set of plans. All changes are clouded under delta 7. Changes include removing/relocating receptacles/lights, and revising floor plans on the basement level. Note: Permit is paid under PCIS#15041-10000-39684	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72252	11041-10002-01464	939 N WESTERN AVE	90038	13	144B193  1184	5535006027	C4-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			09/15/2011 12:00:00 AM			PC Approved	09/15/2011 12:00:00 AM	PIN	34.08785347	-118.30939619	Addition of INTERIOR lighting. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72253	16041-20000-01947	10250 W CONSTELLATION BLVD Levels 31	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.05735	-118.41746	Tenant improvement to (E) commercial office space in (E) commercial highrise building.  Plan check for energy only.  3,853 sq. ft. of meeting room, corridor, and server room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72254	18041-10000-14531	663 S BERENDO ST	90010	10	132B197    68	5094007020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	05/18/2018 12:00:00 AM	ADDRESS	34.0613	-118.29429	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72255	18041-30000-19816	5700 N CANOGA AVE 2nd & 5th	91367	3	174B105    83	2149019015	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.17365	-118.59715	Plan check for T24 only, TI on (E) 2nd and 5th floor commercial space. Install new lights in storage area 5th floor, 106 sq.ft and install new power on office furniture.Provide power on 2nd floor office furniture. Add 9 new circuits from existing panelboards (B# 18016-10000-14024)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72256	18041-10000-34028	8277 S SAN PEDRO ST	90003	9	099B205  1441	6030010017	R3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.96388	-118.26968	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72257	16041-10000-14562	5422 W CARLIN ST #3	90016	10	123B177  1467	5043011003	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	06/14/2016 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.03039	-118.3617	INSTALL 2.915 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  MULTI-UNIT (#3)(11) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB OVI-3.0-OUTD-S-US-Z-A	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72258	13041-10000-23726	12643 W SHERMAN WAY	91605	2	183B161    12	2324003046	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	08/30/2013 12:00:00 AM	ADDRESS	34.20136	-118.40837	PLAN CHECK FOR TITLE 24 ONLY. EMERGENCY LIGHTING. 1 STORY. 1125 SQFT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72259	16041-20000-14532	420 S GRAND AVE	90071	14	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.05094	-118.25298	Plan check for power and energy. Project site is an existing commercial high-rise building. Project scope is the installation of a new 750-kVA UPS and distribution equipment and a tenant improvement to the 14th floor. Total lighting area = 8,875 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72260	19041-10000-12018	600 S CURSON AVE 1ST & MEZZ	90036	4	135B177   426	5508015006	QPB-2, R4-2	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	04/06/2021 12:00:00 AM	ADDRESS	34.06466	-118.35444	TI IN THE EXISTING MUSUME TERRACE LOBBY ON THE 1ST LEVEL AND MEZZANINE. INSTALLNG NEW LIGHTS. T-24 ENERGY ONLY. BULDING PERMIT: 17016-30000-24367	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72261	16041-10000-02101	6201 W HOLLYWOOD BLVD 118	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM			PC Info Complete	01/20/2016 12:00:00 AM	ADDRESS	34.1018	-118.32461	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (SUSHI OF GARI).  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1450 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72262	15041-10000-02309	19301 S PACIFIC GATEWAY DR	90502	15	057B197     4	7351031007	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/26/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	33.85591	-118.29547	PC FOR T24. RELOCATION OF WALK IN COOLERS. TOTAL AREA 7824 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72263	14041-20002-02681	14329 W CARL ST	91331	6	201B153   520	2644024011	R1-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM			PC Approved	04/16/2014 12:00:00 AM	ADDRESS	34.24716	-118.44537	MODIFICATIONS TO APPROVED SET.  ADDITION OF PV METER.  $0 PC FEE DUE TO SENATE BILL 1222 FROM 2012(((CHANGE IN SET OF APPROVED PLANS. CHANGE IN OCPD RATING TO 30A. ADDITION OF SOLAR MONITORING BOX.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72264	15041-20002-18204	4070 S MARLTON AVE	90008	8	114B185   215	5032002048	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			05/24/2016 12:00:00 AM			PC Approved	05/26/2016 12:00:00 AM	ADDRESS	34.01092	-118.33887	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED ON PLANS CLOUDED. CHANGE INCLUDES WATTAGE OF CHANDLIERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72265	19041-20000-24418	10823 N ZELZAH AVE	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	10/23/2019 12:00:00 AM	ADDRESS	34.2668	-118.52366	T24 PLAN CHECK FOR CONVERSION OF OUTDOOR HIDS TO LEDS FOR EXISTING COMMERCIAL BUILDING PARKING LOT. TOTAL SQUARE FOOTAGE = 512,118 SF	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72266	19041-20000-00241	6259 N LUBAO AVE	91367	3	177B113    23	2153009007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2019 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	01/10/2019 12:00:00 AM	ADDRESS	34.18412	-118.56615	Plan check for PV roof mounted system, system size: 13.4kW DC, 12.07kW AC with 40 PV modules and 40 microinverters connected to Center fed panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72267	14041-20000-20875	5900 W WILSHIRE BLVD 17TH FLOOR	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.06237	-118.35809	TITLE 24 ENERGY AND EMERGENCY LIGHTING.  EXISTING HIGH RISE BUILDING.  WORK TO BE PERFORMED IN THE 17TH FLOOR RESTROOM 481SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72268	18041-10000-14542	6117 N RESEDA BLVD STE Q	91335	3	177B125   592	2127016016	C2-1VL-RIO, P-1VL-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Issued	04/20/2018 12:00:00 AM	ADDRESS	34.18114	-118.53622	REPLACE INTERIOR METAL HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72269	17041-10001-38962	6707 W 88TH ST	90045	11	096B161   808	4122020011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	33.95725	-118.4071	EXPEDITE PER APPLICANT REQUEST. ((((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP WITH AC POWERWALL. TOTAL SYSTEM SIZE IS 5.0KWac. ADDING ONE NEW 5.8KVA / 13.5KWH AC POWERWALL. (16)MODULES-SOLARCITY STANDARD SC325(1)INVERTER-SOLAREDGE SE5000A-US-ZB-U(1)AC POWER WALL 5.8KVA 13.5KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72270	14041-10001-02680	4260 E PALMERO DR	90065	1	153A219   100	5475004013	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1862.03	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	04/07/2014 12:00:00 AM	ADDRESS	34.11467	-118.22269	Expedited RSES plan check per applicant request.{{PV1, Install 2.75 KW DC roof-mounted solar array on a one story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3000A-US-ZB-U. (12) Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72271	14041-10001-09902	8958 W FOOTHILL BLVD	91040	7	207B185   438	2547026020	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM			Verifications in Progress	04/29/2014 12:00:00 AM	ADDRESS	34.26199	-118.3275	(((EXPEDITE FEES)))PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72272	14041-10000-34301	1653 N NORTH MAIN ST	90012	1	136-5A219 189	5409003023	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.06753	-118.22652	Plan check for Title 24 only. Scope of work is to remove HID light fixtures and replace with new LED fixtures. Total lighting area = 4824 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72273	14041-20000-20082	1433 N SUMMITRIDGE DR	90210	5	147B157   388	4355005030	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/25/2014 12:00:00 AM	ADDRESS	34.09654	-118.42012	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 201214.3KW PV1 roof-mounted system with (1) 100Amp load center, (2) Solaredge SE6000 inverters, (55) Rec Solar REC260 and Solaredge P300 power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72274	13041-20000-14737	5735 N MELVIN AVE	91356	3	174B117   128	2153025005	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	34.17536	-118.56016	pv1 single family dwelling. total of 14kw. using 2 central inverters transformerless power one. using 49 modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72275	14041-20000-23769	19688 W HORACE ST	91311	12	207B117    84	2708027014	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	09/15/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.26704	-118.56343	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(34) KYOCERA KD 255 MODULES(2) SOLAR EDGE 3800 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72276	17041-10000-30066	5440 N SAN FERNANDO ROAD	90039	13	165B201   253	5593005042	M2-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.15229	-118.27538	PC FOR POWER ONLY. SCOPE INCLUDES NEW MOTORS FOR A GAS DISTRIBUTER(HAZARDOUS LOCATION).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72277	15041-20001-19191	21501 W VENTURA BLVD	91367	3	171B105     7	2168027031	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	PIN	34.16881252	-118.59888323	06-30-15 Change to approve set of plan. Changes includes remove fixture 3 (8)in office and replace with  fixture 1A(18)[[[[[Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 10,210 sq. ft.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72278	18041-30000-29190	2029 S CENTURY PARK EAST #1200	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Issued	08/07/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	INTERIOR OFFICE TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72279	12041-20000-04482	18652 W LOS ALIMOS ST	91326	12	207B121   327	2717018024	RE11-1	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2012 12:00:00 AM	04/24/2012 12:00:00 AM		Permit Finaled	04/27/2012 12:00:00 AM	ADDRESS	34.26521	-118.53997	Roof mounted P.V. system with 10.24 KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72280	18041-20000-24218	1701 W SLAUSON AVE	90047	8	108B193  1251	5003035018	[Q]MR1-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Issued	09/21/2018 12:00:00 AM	ADDRESS	33.98927	-118.30676	Plan check for a PV2 roof-mounted PV system. System size is 72 kWdc/56 kWac and consists of (2) inverters, (180) modules, (1) transformer, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72281	17041-20000-43249	11550 N INDIAN HILLS ROAD ste 261	91345	7	213B149   231	2664023017	[Q]C1-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	04/03/2018 12:00:00 AM		Issued	04/03/2018 12:00:00 AM	ADDRESS	34.27998	-118.45874	ti to an existing commercial building.  medical office.  plan check for power and energy.partial permit fees paid under apllication number 18041-20000-10290	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72282	12041-10000-04265	5555 W MELROSE AVE #315	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	06/01/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	"New Central Plant (Chiller) and cogen facility at Paramount Pictures Studio Building #315.  New underground feeder from existing substation in a ""Methane Buffer Zone"". Change of lighting.  New loads."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72283	17041-10000-31242	17333 W CHASE ST	91325	12	192B133   163	2787021008	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.22314	-118.51084	PC FOR ROOF MOUNTED PV SYSTEM. TOTAL 10AC USING CENTRAL INVERTER AND 34 MODULES. SYSTEM USES POWER OPTIMIZERS.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72284	17041-20000-43924	6707 W 88TH ST	90045	11	096B161   808	4122020011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			Reviewed by Supervisor	12/12/2017 12:00:00 AM	ADDRESS	33.95725	-118.4071	Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.5kW ungrounded pv system. (16) 325W pv modules. (1) Tesla Powerwall 2.Each pv module has a 400W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72285	15041-10000-42998	9200 N OAKDALE AVE 1st Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/21/2015 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.23811	-118.56674	Energy plan check for an office T.I; Plan check for Control Receptacle only. (REMOVE WALL TO COMBINE TWO OPEN OFFICE AREAS.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72286	18041-10000-10275	216 1/2 W 45TH ST	90037	9	112-5A203 166	5110005006	R2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	04/17/2018 12:00:00 AM		Permit Finaled	05/23/2018 12:00:00 AM	ADDRESS	34.00267	-118.27681	PC FOR ROOF MOUNTED PV ON A TRIPLEX. SYSTEM SIZE 1.83KWDC/3.6 KWACSCOPE INCLUDES 6 PANELS AND SINGLE CENTRAL INVERTER ( WITH RSD).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72287	14041-20000-30428	661 E 90TH ST	90002	9	094-5A207  25	6042009020	R1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	33.95482	-118.26317	Roof mounted PV system with Enphase microinverter.  Total system size 4KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72288	18041-10000-22729	1560 W 190TH ST	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	33.85812	-118.30687	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72289	12041-10002-30779	"12746 W JEFFERSON BLVD ""4"""	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM			PC Approved	02/05/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Supplemental plan check only for T-24. Add 3 new fixtures. (((Plan check power and energy for Building 4. Five story parking garage building with common subterranean parking to Building 1, 2, 3, and 4. Service supply from Building 3. Site located in methane zone. Modification to separate fire alarm system has been filed.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72290	13041-20001-07652	1624 S ABBOT KINNEY BLVD	90291	11	108B145  1627	4238017031	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	33.98961	-118.46353	Changes to previously approved set of plans. NO changes to em lighting. Addition of LED strip to outdoor lighting. Plan check for energy and emergency lighting. Bookstore.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72291	19041-10000-50017	1100 S SAN PEDRO ST M10	90015	14	124-5A211 343	5132011237	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.03515	-118.25194	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72292	19041-10000-16964	13038 W SATICOY ST	91605	2	186B161   442	2303022001	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.20697	-118.41722	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72293	15041-10001-07604	1550 W 8TH ST	90017	1	130-5A205 151	5142018001	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			09/09/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Closed	08/01/2017 12:00:00 AM	ADDRESS	34.05213	-118.27207	Changes to an approved set of plans. All changes are made under delta 2. Changes include adding/replacing lighting fixtures, adding 1 panel, replacing Eaton 600A distribution board to a 600A Square D distribution board, and adding new receptacles for office space. (((((((NEW 4 STORY COMMERCIAL OFFICE BUILDING, 600AMPS SERVICE, PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72294	13041-20000-16563	18600 W DEVONSHIRE ST	91324	12	204B121   164	2729011086	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	12/11/2013 12:00:00 AM	ADDRESS	34.25704	-118.53922	Plan check for energy only. Outdoor commercial vehicle service station canopy. Rydell Chevrolet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72295	17041-20000-24598	18535 W CALLE VISTA CIR	91326	12	216B125   278	2872012009	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.28489	-118.53771	PV1.  Install 19.44 kW roof mounted grid tied PV system.  (54) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72296	15041-20001-30998	4244 N WOODCLIFF ROAD	91403	4	165A145    62	2281004002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2015 12:00:00 AM			PC Approved	09/28/2015 12:00:00 AM	ADDRESS	34.1479	-118.46709	Expedite per applicant request[[[[[[Plan check for PV roof mounted system. System size: 10.0kW with 44 modules and 1 inverter(10kW).]]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72297	19041-10000-07572	4253 N EAGLE ROCK BLVD	90065	14	156A219    67	5473024025	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.02	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	09/29/2020 12:00:00 AM	ADDRESS	34.1228	-118.22381	FULL PLAN CHECK FOR A FIRST TIME TENANT IMPROVEMENT OF AN EXISTING RESTAURANT SHELL (1485 SF).  NEW INTERIOR WALLS, KITCHEN/ COFFEE COUNTER, CEILING.B19016-10000-04792	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72298	14041-20001-33368	16780 W OAK VIEW DR	91436	5	168B137   476	2289022015	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2014 12:00:00 AM			PC Approved	02/12/2015 12:00:00 AM	ADDRESS	34.15607	-118.49838	expedite per customer request.pv1install roof mounted pv system sized 13.8kw interconnected with msp.(60) wanxiang solar modules wxs180s(3) powered pvp4600 inverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72299	17041-10000-37869	1130 1/2 S MAPLE AVE	90015	14	124-5A209  95	5145023035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.03626	-118.25563	TITLE 24 ONLY, RELACE INDOOR HID FIXURES WITH NEW LED FIXURES, TOTAL SQUARE FOOTAGE 2700 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72300	19041-10000-27777	1201 N NORTH BROADWAY	90012	1	136-5A217  46	5414021007	C2-2D	Central	Central City North	Historic Cultural North		2060.10	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	09/23/2019 12:00:00 AM	ADDRESS	34.06905	-118.23328	Energy plan check for an office T.I located in a single story building. Scope includes new lighting and equipment with a total lighting area of 5476-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72301	11041-10000-25072	13720 W CUMPSTON ST	91401	2	174B157  1023	2247014082	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	12/09/2011 12:00:00 AM	ADDRESS	34.16942	-118.4319	PLAN CHECK 9.4KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF A SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72302	09041-10001-21028	13955 N BALBOA BLVD	91342	7	228B137   226	2603025028	[Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			01/07/2010 12:00:00 AM			PC Approved	01/08/2010 12:00:00 AM	ADDRESS	34.323	-118.49033	Supplemental is to have plans reflect as-built.  New multilevel switching scheme, occupancy sensors moved from wall --> ceiling type, and emergency lighting. :: New modular building inside a warehouse.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72303	12041-20000-10124	7122 W BEVERLY BLVD	90036	5	138B181   432	5513002032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			05/03/2012 12:00:00 AM			Reviewed by Supervisor	05/15/2012 12:00:00 AM	ADDRESS	34.07599	-118.34481	New nine kw photovoltaic system on roof of  warehouse building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72304	17041-10000-43134	757 S ALAMEDA ST BLDG 3	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	08/13/2018 12:00:00 AM	ADDRESS	34.0318	-118.23916	Install new Fire Alarm system on Building 3 only, this system will connect to the (E) main control panel. (9) FA panels, (467) FA devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72305	19041-30000-26112	6411 W IMPERIAL HWY	90045	11	087B165    12	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	07/09/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	33.93238	-118.3989	Plan check for Title 24 only. Project site is an existing commercial building adjacent to LAX. Project scope is hardscape lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72306	15041-20000-19307	15508 W DEVONSHIRE ST	91345	7	204B145   312	2660001031	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.03	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Closed	02/08/2017 12:00:00 AM	ADDRESS	34.25715	-118.46997	Plan check for Title 24 only. Project site is an existing commercial space (gas station). Project scope is a tenant improvement to yard and canopy lighting. Total outdoor lighting area = 22,100 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72307	15041-20000-11916	5695 S GOLDENEYE CT UNIT 2	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	33.97898	-118.41086	Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALLBE RELAVENT TO UNIT # 1 OF ADDRESS 5695 GOLDENEYE CORT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72308	12041-10002-21774	801 E COMMERCIAL ST	90012	14	130-5A217 174	5173019006	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM			PC Approved	04/17/2013 12:00:00 AM	ADDRESS	34.05272	-118.231	T24 supplemental plan check for outdoor lighting on roof and for hardscape areas.  Additional outdoor lighting added to plan in form of 23 metal halide luminaire J to roof for facade lighting.((((RENOVATIONS IN THE OFFICES OF A STORAGE BUILDING-1ST FLOORPLAN CHK IS FOR TITLE 24 FOR INTERIOR LIGHTING SYSTEMONLY))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72309	15041-20001-02850	12468 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.97899	-118.41015	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72310	15041-10001-16134	17578 W TUSCAN DR	91344	12	222B129   256	2601044014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.3025	-118.51649	EXPEDITED PV1(((PV1, ROOF MOUNTED SOLAR SYSTEM. 18 MODULES AND 1 INVERTER. TOTAL SIZE:  5 KW. SUBMITTED PER APPLICANTS REQUEST. (18) SUNPOWER SPR327NE-WHT-D(1) ABB PV1-5000)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72311	14041-10001-30103	314 W 6TH ST	90014	14	129A211   159	5144003016	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			Reviewed by Supervisor	05/03/2017 12:00:00 AM	ADDRESS	34.0468	-118.25247	PC FOR NEW ELECTRICAL SERVICE FOR EXISTING BLDG. INCLUDES TWO SERVICES  RATED AT 1200A 3PH 208/1202000A 3PH 208/120TOTAL AREA AFFECTED  279 SQ.FTCHANGES TO APPROVED SET DUE TO DWP REQUIREMENTS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72312	18041-10000-48401	731 W PACIFIC COAST HWY	90710	15	036B197   986	7413033040	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.79117	-118.2882	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72313	12041-10000-29344	735 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	06/26/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	NEW TENANT (SPORT CHALET). EXISTING PULL SECTION. FULL PLAN CHECK, ENERGY AND EMERGENCY LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72314	17041-10001-07358	6600 N TOPANGA CANYON BLVD STE 2046	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM			PC Approved	04/14/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	04-14-2017 Changes to an approved set of plans. Changes include replace track light to recess down light.  Changes has been clouded. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72315	14041-20000-29709	1357 W AMAR ST	90732	15	018B193   117	7446004007	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2014 12:00:00 AM			PC Approved	10/27/2014 12:00:00 AM	ADDRESS	33.74769	-118.3055	Modification to approved set, plan check only. Add Solar PV meter to single line diagram for a solar array. Permit originally  approved and pulled under permit #14041-20000-26060.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72316	15041-20001-14172	6320 N TOPANGA CANYON BLVD G-1665	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	08/19/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Recheck for lost plans.   Plan check for power and Title-24.  Total area = 1,389 sq. ft.  T.I. to retail first time tenant.  Two new panels and one new transformer.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72317	18041-10000-36586	6300 W WILSHIRE BLVD 1ST FLR.	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/25/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	05/17/2019 12:00:00 AM	ADDRESS	34.06319	-118.36591	Energy plan check for an office TI located on the first floor of a high rise building; Scope includes new light and equipment with a total area of  4613-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72318	18041-20000-39872	601 S FIGUEROA ST 2100	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only in existing office spce high-rise building T.I. Total area: 3000 sq ft. B#18016-10000-31428	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72319	15041-10000-16419	11818 W WILSHIRE BLVD UNIT 300-PHASE 6	90025	11	129B145   832	4263007146	[Q]C2-1L-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	09/29/2015 12:00:00 AM		Permit Expired	10/25/2017 12:00:00 AM	ADDRESS	34.0474	-118.46308	PHASE 6:REMODEL OF THE CURRENT TENANTS IN VIRTO FERTILIZATION (IVF) LAB AND ADJACENT AREA IN MEDICAL BUILDING.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72320	13041-10000-04065	970 W 190TH ST	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	07/18/2013 12:00:00 AM	ADDRESS	33.85812	-118.29302	ENERGY AND POWER FOR A TENANT IMPROVEMENT IN A HIGH RISE OFFICE BUILDING.  SCOPE OF WORK IS LIMITED TO 6TH AND 7TH FLOORS.  TOTAL INDOOR AREA OF SCOPE OF WORK > 30,000 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72321	16041-20002-04523	4641 N LIBBIT AVE	91436	5	168B137   565	2284001022	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM			PC Approved	05/12/2016 12:00:00 AM	ADDRESS	34.15463	-118.48875	"Modification to approved set: sheet PV-4 only.  Adjusted configuration of (N) main service panel.  ""$0 permit fees due to senate bill 1222 ""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.7 KW"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72322	19041-20001-28061	19602 W CITRUS RIDGE DR	91356	3	171B117   572	2175040004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM			Reviewed by Supervisor	08/29/2019 12:00:00 AM	ADDRESS	34.16219	-118.56065	Void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72323	19041-20000-32056	20813 W ACORN CIR UNIT #169	91326	12	219B109   360	2701098005	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.29455	-118.58708	Plan check for PV roof mounted system, System size: 3.15KW with 9 PV Modules and 9 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72324	17041-10000-32225	2520 S FIGUEROA ST	90007	9	121-5A203  31	5124027016	C2-1VL-O	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.02864	-118.27545	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM DRY CLEANING TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1187 SQ. FT. B#17016-10000-13664	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72325	14041-10000-31842	14800 W VENTURA BLVD	91403	4	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	12/31/2014 12:00:00 AM	ADDRESS	34.15186	-118.45547	"INSTALLATION OF 1600A AUTOMATIC TRANSFER SWITCH  WHICH IN THE FUTURE WILL BE USED TO ALTERNATE SOURCES OF POWER TO A  ""CRITICAL LOAD"" NOT YET CONNECTED TO A POWER  SOURCE . REFERENCE 13041-20000-18841. Notes on plan include: 3p3w connection as well as grouding of both systems."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72326	14041-20001-11826	8976 N LAUREL CANYON BLVD	91352	6	195B165   167	2629019021	[Q]C2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			05/02/2014 12:00:00 AM			Reviewed by Supervisor	05/20/2014 12:00:00 AM	ADDRESS	34.23276	-118.40423	(((EXPEDITE FEES))))CHARLES@SOLARTECUSA.COMPC FOR PV SYSTEM COMMERCIAL ROOFTOP. PV2. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERED INVERTER. NONSTANDARD PLAN. 2 STRINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72327	12041-20000-27850	6300 W WILSHIRE BLVD 19th floor	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM			PC Approved	11/20/2012 12:00:00 AM	ADDRESS	34.06319	-118.36591	Change to lighting on the 19th floor of an existing high-rise office building.  Load is 115.4 amps per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72328	09041-10002-18965	127 S PECAN ST	90033	14	129A219   192	5172002911	OS-1XL	East Los Angeles	Boyle Heights	Boyle Heights		2060.40	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	04/01/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	34.04655	-118.22203	PLAN CHECK FOR INSTALLATION OF A 30KW PHOTOVOLTAIC SYSTEM OVER AN (E) RECREATION BUILDING.  BUILDING PERMIT UNDER #09016-10000-07858(((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((one meter socket was removed and a j box was installed and the mfg of the disconect was changed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72329	14041-20000-07220	7301 N MEDICAL CENTER DR #105	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.20262	-118.62963	New X-Ray room for medical building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72330	15041-20000-43683	9943 N ARLETA AVE	91331	6	201B153   130	2645016001	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	02/02/2016 12:00:00 AM	ADDRESS	34.25073	-118.43555	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.12KWdc/2.5KWdc. (12)MODULES-CANADIAN SOLAR CS6P(1)INVERTER-SMA SB2500HF-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72331	19041-10000-18098	1218 S HOOPER AVE	90021	14	121-5A213 143	5130024016	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	04/18/2021 12:00:00 AM	ADDRESS	34.02705	-118.24253	PC FOR CULTIVATION FACILITY (CHANGE OF USE).SCOPE INCLUEDS NEW POWER AND EQUIPMNENT UNDER 400A. PLAN CHECKER TO VERIFY IF EXTRACTION IS DONE IN THIS FACILITY (FOR HAZARDOUS).TOTAL AFFECTED AREA 55SQ.FT  TO BE VERIFIED.B# 19016-10000-06675	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72332	17041-20000-31490	18155 W VENTURA BLVD	91356	3	171B125   300	2160014024	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.16616	-118.52902	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,149 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72333	17041-10000-18240	8812 S READING AVE	90045	11	096B169   877	4125016001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	33.95743	-118.38145	Replace defective fire alarm control panel and tie in all existing devices.  Install 1 new smoke detector.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72334	17041-10000-05636	5867-5877 1/2 W 88TH ST BLDG 8	90045	11	096B169   870	4125009001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester-Playa del Rey		2772.00	Electrical	Electrical	Apartment			03/07/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Issued	04/18/2017 12:00:00 AM	ADDRESS	33.95713	-118.38502	Plan check for Power only in existing building. Service upgrade to 600A and new panel to each units. This is one building with range of address of 5867-5877 1/2 88th St	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72335	19041-20000-25393	10641 W LOST TRAIL AVE	91040	7	207B173   521	2528037030	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.26412	-118.36692	addition of (1) tesla ESS rated 5KW to an existing pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72336	14041-20000-00426	1826 S VIRGINIA ROAD	90019	10	126B185   802	5071006044	R1-1-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2182.20	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.04104	-118.33423	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 10KWAC. 24 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72337	12041-20000-18015	12181 W BLUFF CREEK DR 1ST FLOOR-#W100	90094	11	102B161  1150	4211010099	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	33.97788	-118.40638	T.I. to a high rise building on the first floor of conference and break rooms.  Install general/emergency lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72338	10041-10000-19992	4376 N ETHEL AVE	91604	5	165B161   274	2362010001	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Apartment			10/07/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	11/04/2011 12:00:00 AM	ADDRESS	34.14989	-118.418	RESUBMITTAL OF LOST PLANS FOR A 8 UNIT APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72339	17041-20000-30988	5914 N NITA AVE	91367	3	177B101   203	2146022009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.17867	-118.61291	Plan check for solar pv system, roof-mounted on SFD. Using standard plan.10kW ungrounded system. (40) 300W pv modules.Each module has a 400W power optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72340	16041-10001-30032	15821 W VENTURA BLVD STE 520	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM			PC Approved	01/05/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	01/05/2017 Changes to an approved set of plans. Changes include lighting fixture change out to different fixture. update Title 24 and photometrics calculation. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72341	14041-10000-10950	1801 S FIGUEROA ST	90015	9	124-5A205 282	5126002009	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	11/24/2015 12:00:00 AM	ADDRESS	34.03524	-118.27179	"plan check for power only. COMBINING SERVICE FOR NISSAN TO (E) MERCEDES BENZ SERVICE. methane zone. Changes on plan include repair garage- ""not hazardous because ventilated"", service rated disconnect; site plan- shows wiring to match SLD; added note isolated neutral and ground for separate buildings.  see comments."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72342	19041-10000-04748	3400 E I ST	90744	15	033B217   921	7429013279	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	04/09/2020 12:00:00 AM	ADDRESS	33.78294	-118.2214	PC TO UPGRADE EXISTING LONG FUELING STATION. THE UPGRADE IS TO ADD 2 NEW LONG PUMP SKIDS. 2 VAPORIZERS, STORAGE BUFFER VESSELS ABOVEGROUND 3-PACK, VAPOR COMPRESSOR, 3 NEW VALVE PANELS TO EXISTING STATION. HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72343	16041-10000-35651	6171 W CENTURY BLVD STE 200	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	33.9457	-118.39324	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SPACE FOR SUITE 200. TOTAL AFFECTED AREA IS 8152 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72344	14041-10000-02896	3148 W PICO BLVD	90019	10	129B193  1332	5073008001	C2-1VL	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.03	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.04701	-118.31079	PLAN CHECK FOR POWER AND ENERGY FOR 'DOLLAR TREE' PER APPLICANT REQUEST. EXISTING 600A, 120,240V, 3PH,4WIRE SERVICE. PROJECTED AREA IN SCOPE OF LIGHTING WORK IS 10845 SQ FT AREA. SIGN LIGHTING ALSO IN SCOPE OF WORK WITH ASSOCIATED  SLTG-1C FORM ATTACHED. ENERGY MANAGEMENT SYSTEM PANEL ALSO IN SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72345	18041-10000-16455	8721 N WILBUR AVE	91324	12	195B121   544	2784003907	OS-1XL, [Q]PF-1XL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			05/03/2018 12:00:00 AM	05/04/2018 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	34.22876	-118.54511	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72346	18041-10000-14368	4359 1/2 N TUJUNGA AVE	91604	2	165B173   492	2365015008	[Q]C2-1XL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	ADDRESS	34.14909	-118.37917	(this is plan check only, permit was issued under 18041-10000-10753)) PLAN CHECK FOR T24 ONLY, CHANGE OF USE FROM RETAIL TO TAKE-OUT RESTAURANT. install (1) 100A panel with its circuitry. TOTAL AREA: 500 SQ.FT((B# 18016-10000-03386))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72347	17041-10000-10652	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Issued	04/07/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	PC FOR REFEED OF A FEEDER ON 5KV (MEDUIM VOLTAGE),  IN VALERO REFIINERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72348	11041-10000-13198	135 S SAN PEDRO ST	90012	14	130-5A213 150	5161016014	[Q]C2-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/24/2011 12:00:00 AM			PC Approved	06/24/2011 12:00:00 AM	ADDRESS	34.04976	-118.2417	T.I.  Remodel of existing cafe on the first floor of a high rise building.  Plan check is for emergency only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72349	18041-10000-07501	523 W 6TH ST VALET AREA	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Issued	05/15/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	OUTSIDE OF THE ENTRANCE OF THE BUILDING IS ENCLOSED TO PROVIDE WAITING / VALET DROP OFF AREANEW LUMINAIRES SUPPLIED FROM EXISTING CIRCUITS PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72350	15041-20000-19285	7603 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.20864	-118.46495	PV1. ROOFMOUNTED SOLAR SYSTEM  FOR SINGLE FAMILY DWELLING. SYSTEM SIZE : 3.6KW  CENTERAL INVERTER SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72351	16041-10000-45802	1124 S SAN JULIAN ST	90015	14	124-5A211 188	5145025002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/27/2017 12:00:00 AM		Permit Closed	02/02/2018 12:00:00 AM	ADDRESS	34.03521	-118.25351	T-24, PC FOR ENERGY ONLY.  CHANGE OF USE FROM WAREHOUSE TO OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 6383 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72352	15041-10001-28085	4226 E VERDANT ST	90039	13	159B205   455	5594006029	[T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	07/16/2018 12:00:00 AM	ADDRESS	34.13138	-118.26456	(THIS IS PLAN CHECK ONLY, PERMIT IS COVERED UNDER MASTER # 15041-10000-28085) PC FOR CHANGES TO AN APPROVED SET. ALL CHANGES MARKED UNDER DELTA 5. SCOPE  INCLUDES ADDITION, REMOVAL  AND RELOCATION OF RECEPTICALS. CHANGES TO FIXTURES INDOOR WITH REVISION TO T-24. CHANGES TO OUTDOORS LIGHT WIRING METHODS. <<<Full plan check for a new SUNDAY SCHOOL, CLASSROOMS, MULTI-USE BUILDING ACCESSORY TO CHURCH BUIDING. Scope include (1) 3000-Amp 480/277V 3-phase service, (11) panels with (183) circuit and total of 48,136-SQ feet for T24.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72353	18041-20001-26970	640 N LAS LOMAS AVE	90272	11	129B121   819	4414013009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2627.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2018 12:00:00 AM			PC Approved	10/10/2018 12:00:00 AM	ADDRESS	34.04692	-118.53922	10/10/2018changes to an approved set of plans.  changes to reflect current field conditions.  this is plan check only.((((pv1install roof mounted pv system sized 7.3KW AC interconnected with msp.(20) LG365Q1C-A5 modules))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72354	17041-20000-32021	17309 W ROSCOE BLVD	91325	12	192B133   237	2787020030	P-1VL, QC2-1VL	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.22128	-118.51035	Plan check for energy only. TI/change of use from retail to beauty salon. New lighting (incl. emergency) - 1,200sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72355	15041-20001-41807	837 S HARVARD BLVD	90005	10	132B193   774	5093017019	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.01	Electrical	Electrical	Apartment			11/15/2017 12:00:00 AM			PC Approved	11/15/2017 12:00:00 AM	ADDRESS	34.05675	-118.30436	11/15/17changes to an approved set of plans.  changes noted delta 2.  changes include revised electrical room. this is plan check only.(((Full pc for a New 6 story, 65 unit 5 level apartment building over a 2 level subterranean garage. Total area is 50359 sq. ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72356	14041-10004-34971	416 S WESTLAKE AVE	90057	1	133-5A205 196	5154026015	R4-1	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	09/19/2016 12:00:00 AM	ADDRESS	34.06015	-118.27263	THIS IS PLAN CHECK FOR ADDITION OF APARTMENT UNIT PANELS TO SCOPE OF WORK. ADDING 37 PANELS TOTAL TO RECONNECT EXISTING BRANCH CIRCUIT WIRING. 35 UNITS AND 2 HOUSE PANELS IN TOTAL. RECHECKING FOR NEW AIC RATINGS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72357	15041-10000-42649	2022 S PACIFIC AVE	90291	11	106-5A145 377	4238022001	[Q]C1-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	01/20/2016 12:00:00 AM		Permit Finaled	02/26/2016 12:00:00 AM	ADDRESS	33.98521	-118.47003	PC FOR ENERGY.  T.I. FOR FOOD AND VINE ONE STORY BUILDING. NO CHANGE OF USE. TOTAL AREA 1226 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72358	13041-10000-03409	4945 N EAGLE ROCK BLVD UNIT A	90041	14	160-5A221  31	5686020022	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM	02/11/2013 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.13606	-118.21531	PC FOR ENERGY. TI EXSITING BLDG BEFORE: BANK - NOW: TIMEWARNER RETAIL. less than 400A Tenant improvement to add and remove interior non-bearing partitions walls and finishes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72359	10041-20000-00672	6300 W WILSHIRE BLVD 160	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/13/2010 12:00:00 AM	01/15/2010 12:00:00 AM		Permit Finaled	04/08/2010 12:00:00 AM	ADDRESS	34.06319	-118.36591	T.I work in office building unit 1600 changing light fixtures and power. This P/C is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72360	14041-10000-35499	1420 W FRANCISCO ST	90501	15	057B197   120	7351037018	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/23/2014 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.85005	-118.30021	Remove HID fixtures and replace with LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72361	11041-20000-14620	1334 S CENTRAL AVE	90021	14	121-5A213   5	5130008042	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.02855	-118.24651	Plan check T24 energy only. General/Emergency lighting for Blow Mold Project area. Permit for new equipment to existing electrical system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72362	19041-10000-46802	1914 S MATEO ST	90021	14	120A217    73	5167011037	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Issued	11/14/2019 12:00:00 AM	ADDRESS	34.02305	-118.23225	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72363	10041-10000-15184	1500 E LOMITA BLVD	90744	15	036B209    10	7426006001	[Q]M3-1VL, [Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			08/04/2010 12:00:00 AM	06/03/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	33.79983	-118.25006	INSTALLATION OF A PAD-MOUNTED LNG DISPENSING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72364	13041-10000-34125	9000 S AIRPORT BLVD	90045	11	093B169     6	4125010016	[T][Q]M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	33.95466	-118.38556	Installation of emergency shut off relays for existing fueling dispensers.Using existing branch circuits. Permit is on 13041-90000-22735	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72365	15041-20000-17044	20930 W SHERMAN WAY	91303	3	183B109    71	2112031004	[Q]C2-1VL-CDO-RIO, [Q]P-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Expired	06/28/2017 12:00:00 AM	ADDRESS	34.20085	-118.58955	Plan check for Title 24 out door light. Total area: 566 SQ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72366	18041-20002-25370	4221 N CLEAR VALLEY DR	91436	5	165B137   318	2284019024	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2018 12:00:00 AM			PC Approved	08/30/2018 12:00:00 AM	ADDRESS	34.14749	-118.48569	Revisions to approved set of plans.  Change of module type and change of # of modules to (36).  $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414. (((PV1.  Install 11.375 kW roof mounted grid tied PV system.  (35) modules with SolarEdge 11.4 kW rated string inverter.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72367	18041-20000-36937	1825 S MESA ST LOT 18	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	33.7273	-118.28615	Plan check for PV roof mounted system, system size: 3.02KW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72368	17041-20000-17426	4094-4096 S GLENCOE AVE	90292	11	108B153  1063	4230006003	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	33.99	-118.44273	New lighting system for commercial building outdoor parking lot.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72369	18041-10000-15619	700-800 WORLD WAY	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/27/2018 12:00:00 AM			PC Approved	04/27/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	PLAN CHECK FOR TITLE 24 ONLY FOR NEW LOCKER ROOM (1177sf) AT TERMINAL 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72370	19041-20000-12125	20427 W TIARA ST pv1	91367	3	177B109   191	2151001038	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.17721	-118.57848	pv1install roof mounted pv system sized 7.6KW AC interconnected with msp.This is an addition to an existing pv system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72371	19041-20000-36212	3863 N BUENA PARK DR	91604	2	162B169   578	2369024022	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.13967	-118.38869	Plan check for PV roof mounted system with battery back up system, PV system size: 8.23KW DC, 7.6KW AC with 25 PV Modules and 2 Tesla Battery. Energy storage system size: 27KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72372	12041-20000-27560	17100 W LORNE ST	91406	6	189B133   223	2204007001	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	ADDRESS	34.21712	-118.50575	Photovoltaic system on roof of single family dwelling using enphase M215 inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72373	17041-30000-33507	2049 S CENTURY PARK EAST 12th Floor-Lobby	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Issued	09/26/2017 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 onl. in existing highrise elevator lobby 12 Floor. Total area: 295 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72374	17041-20001-40867	12656 N RALSTON AVE	91342	7	219B149    57	2506032030	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.30038	-118.45635	PV1.  Install roof mounted PV system sized 11.4kW interconnected with MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72375	16041-10000-28338	5551 W JEFFERSON BLVD	90016	10	120B173   295	5048017008	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			08/10/2016 12:00:00 AM			PC Info Complete	10/04/2017 12:00:00 AM	ADDRESS	34.02639	-118.36802	Plan check for new 4-story, 9 units Appartment building , with subterranian parking. 800 A Service (UPS) 3-phase 4W 240V. Total area: 11,000 sq ft.  Project NOT under Methane zone per zimas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72376	14041-20000-19010	2030 S SAWTELLE BLVD	90025	11	126B153   753	4261032056	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			07/15/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	34.04031	-118.44289	Change of use from retail to restaurant.  Power and energy.  Bldg permit assembly occupancy load of 103.Existing permit already pulled under 13041-10000-30524.  Plan check only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72377	14041-10000-09786	2641 S DELEVAN DR	90065	14	159A219   306	5684022007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	34.12921	-118.2259	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM WITH SOLAR EDGE OPTIMIZERS. TOTAL SYSTEM SIZE 10.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72378	15041-20000-16265	6220 N TOPANGA CANYON BLVD	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	ADDRESS	34.1841	-118.60553	Plan check for power only. Project scope is the installation of pool and spa equipment, which includes pumps and lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72379	15041-10000-21475	5637 N COSTELLO AVE	91401	2	174B153   641	2246031004	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.17322	-118.43793	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW (3+3). Ungrounded system. (20) 327W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72380	15041-20000-35609	1234 S ELDEN AVE	90006	1	129B197   932	5076017007	R3-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Expired	11/22/2017 12:00:00 AM	ADDRESS	34.04809	-118.28756	PV1 SFD TOTAL SYSTEM SIZE 8.6KW AC UISNG TOTAL OF 2 CENTRAL INVERTERS AND 36 MODULES. USING STANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72381	16041-20000-08868	870 S HILGARD AVE 1-77	90024	5	135B153   384	4360007028	[Q]R4-1VL	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	Apartment			03/14/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.06469	-118.4407	$0 permit fee is due to State Senate Bill SB-1222PV2.  Install 81.9 kW roof-mounted PV system.  (5) 14kW inverters with (260) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72382	19041-20000-14502	17431 W VICTORY BLVD	91406	6	180B129   989	2229031006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.1869	-118.51322	PLAN CHECK FOR INSTALLTION OF A NEW ROOFTOP PV SYSTEM ON EXISTING ADU. SYSTEM SIZE IS 7.2KW DC/6.4KW AC. SCOPE OF WORK INCLUDES (20) SUNPOWER PV MODULES WITH INTEGRATED MICROINVERTERS, AND (2) 100A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72383	10041-20000-16377	13050 W SAN VICENTE BLVD 116	90049	11	129B137   501	4264001021	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/19/2010 12:00:00 AM	08/19/2010 12:00:00 AM		Permit Finaled	09/14/2010 12:00:00 AM	ADDRESS	34.0483	-118.49125	LIGHTING IN RETAIL STORE. ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72384	14041-10000-30103	314 W 6TH ST	90014	14	129A211   159	5144003016	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	05/19/2022 12:00:00 AM	ADDRESS	34.0468	-118.25247	Full plan check for power and energy for a mixed use building including (10) commerical tenants in the first floor and 50 units appartments on the 2nd -6th floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72385	19041-20000-25972	4874 W SANTA MONICA BLVD	90029	13	144B197   774	5538019017	C2-1D	Central	Hollywood	East Hollywood		1915.00	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM			PC Approved	07/08/2019 12:00:00 AM	ADDRESS	34.09065	-118.29575	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,219 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72386	17041-10000-21343	1721 N NAUD ST	90012	1	136-5A219  79	5409002029	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	34.06911	-118.22594	PLAN CHECK FOR POWER AND ENERGY FOR TI (CHANGE OF USE FROM PAINT SHOP TO RESTAURANT). PLAN CHECK INCLUDES TEMPORARY  CONNECTION,  POWER WILL BE SUPPLIED BY 2 EXISTING SERVICES, 100A AND 400A. TOTAL AFFECTED AREA =  6672 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72387	15041-20000-11346	2383 W 21ST ST	90018	10	126B189  1155	5073026011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.0382	-118.31728	Installation of new roof mounted solar PV array.  Total system size = 5 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72388	15041-20000-29774	1936 S SELBY AVE	90025	5	129B157   763	4321010032	R3-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			09/09/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.04888	-118.43182	Plan check for a fire alarm system. Project site is a 4-story, 8-unit apartment building. System consists of (1) FACP, (1) annunciator, (1) RPS, and (49) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72389	18041-10000-24654	1875 S CENTURY PARK EAST UNIT 1860	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.06115	-118.41457	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2471 SQ. FT. B#18016-10000-19714	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72390	18041-10000-33396	115 E 3RD ST	90013	14	129A213    62	5161026004	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04908	-118.24546	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72391	18041-10000-35651	777 S FIGUEROA ST # 750	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Tenant improvement in open and private officesPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCT CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72392	14041-10000-07027	15751 W ROXFORD ST STE C	91342	7	222B141    45	2604002022	[T][Q]MR1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	04/03/2014 12:00:00 AM	ADDRESS	34.30837	-118.47526	T24 ONLY REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW  FLORESCENT FIXTURES, TOTAL AREA 2101 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72393	19041-10000-48927	1282 W 2ND ST	90026	1	133-5A209 209	5152010013	CW	Central	Westlake	Westlake North	YES	2080.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/05/2019 12:00:00 AM	ADDRESS	34.06053	-118.25851	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72394	13041-10001-35652	1455 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.09728	-118.31598	ADDITIONAL PLAN CHECK HOURS REQUIRED TO VERIFY significant CHANGES under delta 1. Service changed from utility to campus medium voltage substation. Provisions for satellite power installed on roof. Increased size of distribution equipment due to EV charger load. Emergency lighting changed. Lighting changes.  Parking structure will be linked to the KTLA bldg on site via an underground tunnel walk-way.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72395	12041-20000-12311	1801 E 50TH ST	90058	9	111A213   156	5106027004	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	ADDRESS	33.99812	-118.24177	energy plan check edge clothing	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72396	19041-20000-19100	1021 N MISSION ROAD	90033	14	133-5A221  82	5410001008	[Q]M2-1-RIO	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.05962	-118.21597	Change of use from manufacturing to hydroponics and manufacturing.  Three existing services at building: 800A 240/120V 3ph-4w, 200A 240/120V 3ph-4w, and 200A 240/120V 1ph-3w.  New downstream distribution and loads.  Plan check for power and energy.  Building permit under 18016-20000-39744.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72397	12041-10000-15408	230 S SANTA FE AVE	90012	14	127-5A217   3	5163017***	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Closed	12/08/2014 12:00:00 AM	ADDRESS	34.04661	-118.2324	PLAN CHECK TEMP POWER FOR CONSTRUCTION OF NEW MIXED USE BUILDING IN METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72398	14041-20000-29321	8851 N KATHERINE AVE	91402	6	195B149   323	2639015013	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.23128	-118.4466	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP.(15) SUNPOWER E-20 327 MODULES(1) SUNNYBOY 5000 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72399	19041-20000-23307	7327 N KESTER AVE Bldg.A#1-3	91405	6	186B149   653	2221014008	RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			06/18/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	08/26/2019 12:00:00 AM	ADDRESS	34.20387	-118.45764	PLAN CHECK FOR NEW 600A SERVICE FEEDING 2 NEW 3-STORY 3-UNIT TOWNHOUSE APARTMENTS WITH ATTACHED GARAGES. T24 INCLUDED. TOTAL SQUARE FOOTAGE = 2605 SFSCOPE OF WORK INCLUDES A 600A PANEL, (3) 125A PANELS, AND A 60A HOUSE PANELService installed on Building A.UNDER B#16010-20000-01945 UNIT A 1-3Second elec permit for building B under: 19041-20000-26397	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72400	19041-10000-52600	8716 S CENTRAL AVE	90002	9	096A209    43	6043002018	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM			PC Approved	12/19/2019 12:00:00 AM	ADDRESS	33.95872	-118.25618	T.I. PC FOR T-24 ENERGY ONLY FOR A DAY CARE. AFFECTED AREA 870sqft.************************************************************************************PER BUILDING APPLICATION# 18014-10000-04516Change of use from----- to Child Care Center.  and additon to rear of building and interior t.i.,  children (1-5 years).************************************************************************************	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72401	15041-20000-31721	221 N FIGUEROA ST 3RD FLR	90012	14	133-5A211 255	5161006909	C4-2D, [Q]C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM			PC Approved	09/24/2015 12:00:00 AM	ADDRESS	34.05882	-118.25099	TI TO 3RD FLOOR. PC FOR ENERGY ONLY. NEW LIGHTING AND REBUILD OF FIRE DAMAGED SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72402	12041-10000-22442	5350 N CAMPO ROAD	91364	3	171B105   109	2168001033	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.16746	-118.59876	NEW 2.616 ROOF MOUNTED PV FOR A SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72403	11041-10000-25338	15750 W STRATHERN ST Room 100	91406	6	189B141    84	2206003016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM			Corrections Issued	12/06/2011 12:00:00 AM	ADDRESS	34.21559	-118.47652	T.I. to existing office space in a warehouse.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72404	19041-30000-16910	1333 S BEVERLY GREEN DR pv2	90035	5	129B165  1242	4330004045		West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			05/14/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/15/2020 12:00:00 AM	ADDRESS	34.05319	-118.40537	Plan check for a PV2 roof-mounted PV system. System size is 9.1 kWdc/7.6 kWac and consists of (1) inverter and (26) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72405	18041-20001-25197	9301 N TAMPA AVE STE. 109	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	10/9/2018changes to an approved set of plans.  changes to reflect field conditions. changes noted delta 8 only.  thi sis plan check only. ((((PLAN CHECK FOR TITLE 24 ONLY FOR - TI WORK FOR NEW TENANT IN EXISTING RETAIL SPACE. (N) NON BEARING WALLS, FINISHES, NEW FURNITURE AND FIXTURES - TOTAL AFFECTED AREA = 820 SF))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72406	15041-20001-43734	22840 W VICTORY BLVD	91367	3	180B097   629	2039007030	C2-1, C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	Commercial			04/22/2016 12:00:00 AM			PC Approved	04/22/2016 12:00:00 AM	ADDRESS	34.18624	-118.62454	4.22.2016 - Plan check for modifications to approved set. Floor plan of back of house changed which resulted in some equipment being relocated (same circuits), the indoor lighting layout being reconfigured, and some new indoor lights being added. T-24 forms updated to reflect new indoor lighting layout and fixture counts.====TI TO RETAIL SPACE. NEW DISTRIBUTION EQUIPMENT AND LIGHTING. PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72407	16041-10001-09959	10960 W WILSHIRE BLVD #120	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/24/2016 12:00:00 AM			PC Approved	03/24/2016 12:00:00 AM	ADDRESS	34.058	-118.44597	SMALL OFFICE T.I. permit already issued. this is plan check for energy. t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72408	10041-20000-20777	4301 N CAHUENGA BLVD	91602	4	165B177   691	2423018019	[Q]R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Public Safety Only			10/19/2010 12:00:00 AM	10/19/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.14816	-118.36164	Plan check for new installation of fire alarm system for church	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72409	10041-20000-15334	3450 S WATT WAY CTV	90089	8	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM	10/01/2010 12:00:00 AM		Permit Finaled	01/04/2011 12:00:00 AM	ADDRESS	34.02275	-118.28604	energy class room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72410	19041-20000-44223	20310 W PASEO DEL CAMPO	91326	12	213B113   359	2701080***	C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			10/29/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Issued	10/29/2019 12:00:00 AM	ADDRESS	34.27686	-118.57649	PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 8.32 KW DC/8.19 KW AC. SCOPE OF WORK CONSISTS OF (26) PV MODULES WITH MICROINVERTERS AND A COMBINER PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72411	11041-10004-14359	240 E 6TH ST	90014	14	127-5A211 145	5148023020	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Apartment			10/04/2013 12:00:00 AM			PC Approved	10/04/2013 12:00:00 AM	ADDRESS	34.0435	-118.24761	REVISED APPROVED SET OF PLANS TO INCLUDE AS-BUILT CHANGES Add a 1-story parking garage over an existing 1 story commercial building.  Also adding an additional 4-story 102 unit apartment buildings (modular built -state-approved apartment units) on top.  Plan check is for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72412	16041-10000-41570	1625 W OLYMPIC BLVD 9TH FLR	90015	1	130-5A203 305	5137002033	C2-2D, C4-2D	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.04973	-118.27494	T-24, PC FOR ENERGY ONLY. TI TO EXISTING RESTROOMS ON THE 9TH FLOOR OF A COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 363 SQ. FT B#16016-10000-20546	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72413	16041-20000-39660	2315 S LA BREA AVE	90016	10	123B181   268	5062017029	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Issued	11/14/2016 12:00:00 AM	ADDRESS	34.03614	-118.34957	ti to an existing commercial building.  adding new lighting new controls to new panel.  newly connected load < 400 amps.  plan check for energy and em lighting.  total square footage 4268.power check requested by applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72414	18041-20001-31156	8524 N WILBUR AVE	91324	12	192B121   213	2785011005	R1-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.22529	-118.54464	PV1.  Install 14.7 kW DC/15.2 kW AC roof mounted grid tied PV system.  Derating of main breaker to 175A.  (42) modules with 11.4 and 3.8 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72415	17041-10000-43842	8405 W BEVERLY BLVD	90048	5	138B173   413	5514011052	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			Reviewed by Supervisor	12/22/2017 12:00:00 AM	ADDRESS	34.07622	-118.37338	PC FOR TI TO AN EXISTING 3 STORY OSPHO 3 CLINIC FOR POWER AND ENERGY. SCOPE INCLUDES NEW PANELS CIRCUITS EQUIPMENTS,  LIGHTS AND GENERATOR. TOTAL AFFECTED AREA 14430 SQ.FTB#17041-10000-05958	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72416	17041-20001-29153	8534 N MARKLEIN AVE	91343	6	192B145   136	2654019007	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/21/2017 12:00:00 AM	ADDRESS	34.22557	-118.47082	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 4.2 kWac and consists of (1) inverter, (18) modules, (1) 5 kWac Powerwall, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72417	13041-10001-33048	12476 W TIBBETTS ST	91342	7	228B165    62	2582029055	RS-1	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.32139	-118.4055	Expedited RSES plan check per applicant request.[][][]PV1, Install 5.5 kW DC roof-mounted solar array, interconnect with service panel.(1) Transformerless inverter(s):Solaredge SE5000A-US. (22) modules TRINA SOLAR TSM-250PA05.18	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72418	14041-20000-24240	1640 N OLD RANCH ROAD	90049	11	135B137   597	4426002019	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.06222	-118.49537	Plan check for power only. Remodel/Addition to existing single family dwelling (3 stories). All electrical equipment is brand new. New 800A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72419	13041-10000-00873	650 S AVENUE 21		1	135A221    76	5410016002	M3-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			01/14/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	PIN	34.06374638	-118.2175984	PLAN CHECK FOR POWER AND ENERGY GYMNASIUM (PLACE OF ASSEMBLY ARTICLE 518).NOTE: EXISTING PERMIT UNDER 13041-20000-29708	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72420	18041-10001-16647	819 E 246TH ST	90744	15	039B209   190	7404031006	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	33.80237	-118.25906	Supplemetal plan check and permit to 18041-90000-16647. Change from 32 modules on the original plan to 38 modules on the current plan. ((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwellin))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72421	18041-10001-47161	20440 W VIA CELLINI VOID	91326	12	219B109   257	2701055007	RE11-1-H, RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	02/04/2019 12:00:00 AM	ADDRESS	34.29433	-118.58051	**applicant decided to not expedite**New rooftop solar system on a SFD,  system size 10kW AC, (1) 10kW SE inverter, (32) modules, (32) power optimizer P400. Main panel is split bus, and downsized main breaker from 200A to 175A (load calculation is included)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72422	16041-10000-18093	3134 E FOLSOM ST	90063	14	127-5A227 231	5178021029	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.04377	-118.19662	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.77KWdc / 3.6KWac.(18)MODULES-KYOCERA#KU265ZPA(1)INVERTER-ABB #PVI-3.6-OUTD-S-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72423	18041-10000-41728	5629 N LANKERSHIM BLVD	91601	2	174B169   740	2338027008	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1241.02	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.17299	-118.37974	PC FOR TI, CHANGE OF USE FROM RETAIL TO A RESTAURANT. T-24 ONLY. TOTAL AFFECTED AREA IS 870 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72424	18041-10000-30277	8511 N FALLBROOK AVE 3RD FL	91304	12	192B097   585	2005022004	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.22466	-118.62773	TI IN AN EXISTING OFFICE AREA IN SUITE NUMBER 300 (30,000 SF). T-24 ENERGY ONLY. (SUBJECT TO FIELD INSPECTION) BUILDING PERMIT: 18016-10000-19838	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72425	18041-10000-40158	110 E 9TH ST	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Closed	12/31/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	Temporary powewr for construction. Existing Service. Nwew transformers, Spider Boxes & Distribution Panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72426	14041-20000-09326	5444 N YOLANDA AVE	91356	3	174B121   791	2161015001	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM	04/08/2014 12:00:00 AM		Permit Finaled	05/14/2014 12:00:00 AM	ADDRESS	34.17002	-118.54025	INSTALLING LOW VOTAGE CABLE.	N	N	Express Permit	06/10/2024 12:00:00 AM
72427	18041-20000-30148	1559 N PARMER AVE	90026	13	141A211    92	5419014023	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1973.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.08086	-118.25391	Plan check for a PV1 roof-mounted PV system. System size is 2.97 kWdc/2.73 kWac-CEC and consists of (9) modules and (9) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72428	17041-10001-19823	3576 N LOWRY ROAD	90027	4	154-5A203 292	5592008022	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM			Verifications in Progress	08/03/2017 12:00:00 AM	ADDRESS	34.11638	-118.27726	Expedite fees only.       Installation of new roof mounted solar PV system on existing single family dwelling with battery back up system.  One new Solaredge SE10000A with 32 Solarcity Standard SC325 modules and 2 Tesla AC Powerwall 5.8 kVA / 13 kWH batteries.       PC only.       Solar PV permit #17041-90000-15253Battery permit #17041-90000-15254	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72429	18041-10000-36484	10348 N SEPULVEDA BLVD	91345	7	204B145   168	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM			PC Approved	09/24/2018 12:00:00 AM	ADDRESS	34.25886	-118.46706	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CHASE BANK. 8130 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72430	19041-20000-50382	4575 W DUNDEE DR	90027	4	153B197    43	5588033022	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.1172	-118.28756	$0 fee per AB1414PV1 PLAN CHECK FOR NEW ROOF PV AND ESS. SYSTEM SIZE IS 16.17 KW DC/14.89 KW AC CEC. ESS SIZE IS 13.5 KWH. SCOPE OF WORK CONSISTS OF (49) PV MODULES WITH MICROINVERTERS, (2) SUB PANELS, AND (1) 13.5 KWH BATTERIES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72431	14041-10000-21463	3335 S FIGUEROA ST O	90007	9	120A203   503	5123009042	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	10/27/2014 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.02224	-118.28008	Plan check at counter. New power/lighting system upgrade. electrical service for sub-lease space. T24. Area = 3450 sq. ft. 8 story building High rise	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72432	17041-20000-05515	4849 N VAN NUYS BLVD	91403	4	169-5A151  98	2263024050	C1.5-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	03/20/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.15918	-118.44892	ti to an existing commercail building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 1229.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72433	10041-20000-22528	933 N LA BREA AVE Suite #200	90046	5	144B181   679	5531016022	MR1-1	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	01/05/2011 12:00:00 AM	PIN	34.08817379	-118.34466503	TI IN AN EXISTING OFFICE AREA ON THE 2ND FLOOR SUITE # 200. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72434	10041-10000-05528	16710 W VENTURA BLVD	91436	5	168B137   335	2289020019	(Q)C4-1L, R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	05/13/2010 12:00:00 AM		Permit Finaled	09/10/2013 12:00:00 AM	ADDRESS	34.15819	-118.49729	New fire alarm system for a 125 unit mixed use apartment complex.  The power to the FACP and RPS units shall be provided by 3 branch circuits to be permitted and installed to comply with NFPA 72 - 4.4.1.4.2 by an electrical contractor coordinating with the fire alarm contractor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72435	12041-20000-18083	801 N AMALFI DR	90272	11	126B133    60	4408012001	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	09/25/2012 12:00:00 AM	ADDRESS	34.04414	-118.51023	Replace the existing service with a new 600A service, convert the original service to a distribution board to supply existing loads, install a new subpanel to supply a new heater panel and the existing pool panel, install radiant heaters in the exterior canopy, and replace existing AC units one for one at the existing panel A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72436	18041-20001-11878	750 S WESTLAKE AVE 1-5	90057	1	132A203   268	5142003009	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			05/21/2018 12:00:00 AM			PC Approved	05/21/2018 12:00:00 AM	ADDRESS	34.05449	-118.27638	05/21/2018 Plan check for a PV2 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (27) modules. *****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72437	10041-10000-04183	4520 W ELECTRONICS PL	90039	4	162B205    11	5593012025	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			03/09/2010 12:00:00 AM	04/12/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.14462	-118.27312	TI IN AN EXISTING COMMERCIAL BUILDING. PLAN CHECK IS FOR POWER AND ENERGY.  EXISTING SERVICE, NEW PANELS & LOADS.  FIRE LIFE SAFETY IS SUBMITTED UNDER 10041-10000-04184.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72438	15041-20000-20896	4513 N LENNOX AVE	91423	4	168A151   244	2265016024	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/10/2015 12:00:00 AM		Permit Finaled	09/15/2016 12:00:00 AM	ADDRESS	34.15345	-118.44556	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 20 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72439	19041-20000-16770	17052 W PAULETTE PL	91344	12	219B133   337	2608023008	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.29774	-118.50436	Plan check for PV roof mounted system, system size: 12.96KW DC, 11.52KW AC with 36 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72440	10041-10001-08551	10250 W SANTA MONICA BLVD #154, #155	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/08/2010 12:00:00 AM	10/12/2010 12:00:00 AM		Permit Finaled	08/21/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	New restaurant in Century City Mall. Unit # 154 & 155. Plan Check is for power & energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72441	10041-20000-19870	19307 W VENTURA BLVD	91356	3	174B117   304	2163001018	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.00	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	12/06/2010 12:00:00 AM	ADDRESS	34.17284	-118.55387	PLAN CHECK T-24 ENERGY GENERAL/EMERGENCY LIGHTING FOR CHANGE OF USE FROM RETAIL TO BEAUTY SALON & TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72442	16041-20001-38625	8160 N WHITSETT AVE	91605	2	192B165   769	2308018008	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2016 12:00:00 AM			PC Approved	11/08/2016 12:00:00 AM	ADDRESS	34.21958	-118.40508	Expedite per applicant request.Plan check for PV system roof-mounted on SFD. 13.25kW ungrounded system. (41) 345W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72443	19041-20000-44449	19427 W OLIVOS DR	91356	3	168B117   174	2175006021	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	34.1584	-118.5559	PV1. INSTALL 13.86 KW DC PV SYSTEM WITH (44) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72444	14041-10000-06867	1150 S OLIVE ST SUITE 2250	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM			PC Approved	03/13/2014 12:00:00 AM	ADDRESS	34.03962	-118.26181	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY, NEWLY CONNECTED LOAD <400 A. 22ND FLOOR. SUITE 2250.6080 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72445	16041-10000-38738	727 S BROADWAY #118	90014	14	133-5A215  52	5408021015	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	12/16/2016 12:00:00 AM		Permit Closed	11/28/2023 12:00:00 AM	ADDRESS	34.04463	-118.25416	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RETSTAURANT. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 619 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72446	17041-10001-03748	1635 N BLUE JAY WAY	90069	4	147B169    57	5561026013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM			Reviewed by Supervisor	02/15/2017 12:00:00 AM	ADDRESS	34.10272	-118.38708	Expedite per applicant requestPlan check for PV roof mounted battery backup system on SFD. System size: 15.0kW with 60 modules HYUNDAI HISM250MG and 2 inverters(7.5kW) SOLAR EDGE, 2 (5kW) Battery back up by Tesla Power Wall Home connected to 800A Swtich gear.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72447	15041-10000-05458	18620 S WESTERN AVE	90248	15	060B193   249	6108002019	C2-1, P-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	04/20/2015 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	33.86143	-118.30895	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 921	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72448	17041-10001-44014	2826 E 1ST ST	90033	14	126A225    44	5180014003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.04097	-118.20394	PC FOR CHANGES TO APPORVED SET PER APPLICANT REQUEST UNDER DELTA 2 ONLY! SCOPE INCLUDES CHANGE TO FLOOR PLAN MAINLY TO THE FIRST LEVEL. CHANGES TO LIGHTING AND T-24 INCLUDED. NO NEW CIRCUITS, EQUIPMENT OR PANELS. THIS IS PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72449	16041-10001-15301	902 E 59TH ST	90001	9	105B209    37	6007004004	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Permit Finaled	05/10/2022 12:00:00 AM	ADDRESS	33.98705	-118.25942	DELTA 1 CHANGES TO APPROVED SET. CHANGES INCLUDE NEW 200A PANEL FOR FUTURE TENANT CONNECTED TO APPROVED 1200A SERVICE. NO LOAD ADDED TO PANEL A, TENANT TI TO BE PERMITTED SEPERATELY. HOUSE PANEL LOADS ARE REVISED****NEW 1200 AMP SERVICE CORE AND SHELL.  PC FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72450	14041-10000-34729	8556 S EMERSON AVE UNIT 4	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	01/30/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	Bldg 4 of 12.  (12) new townhomes supplied from (2) 600A services.  Service points adjacent to buildings 6 and 12.  Plan check for power.  Associated electrical permits:Unit 1:   14041-10000-34721Unit 2:   34728Unit 3:   34727Unit 4:   34729Unit 5:   34726Unit 6:   34719Unit 7:   34720Unit 8:   34730Unit 9:   34733Unit 10: 34725Unit 11: 34731Unit 12: 34732	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72451	16041-10000-22981	5014 N EAGLE ROCK BLVD	90041	14	162A223   263	5686004018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	34.1374	-118.21433	PC FOR ENERGY. CHANGE OF USE FROM RETAIL (M-OCC) TO OFFICE (B-OCC) AND ADDITION OF  TWO ADA RESTROOMS. NEW CONNECTED LOAD LESS THAN 400 A. TOTAL AFFECTED AREA IS 3086 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72452	15041-10000-03978	3923 S BLEDSOE AVE	90066	11	114B157   948	4214007026	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.00811	-118.41983	Plan check for a PV1 roof-mounted PV system. System size is 3.6 kWac and consists of (19) modules, (1) inverter, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72453	18041-20000-03334	3831 S HUGHES AVE #704	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			01/29/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	06/15/2018 12:00:00 AM	ADDRESS	34.02242	-118.39823	Medical office TI on 7th floor of medical office building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72454	18041-20001-10316	11320 W MAGNOLIA BLVD	91601	2	171B173   672	2353002008	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM			PC Approved	04/20/2018 12:00:00 AM	ADDRESS	34.16469	-118.37817	"4/20/2018changes to an approved set of plans.  changes to reflect field conditions.  changes include ""existing room 104 with new lighitng"".  this is plan check only.  (((ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only)))."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72455	13041-20001-35610	6501 W HOLLYWOOD BLVD	90028	13	148-5A187 136	5547007010	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.01	Electrical	Electrical	Commercial			04/25/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.10176	-118.33115	MODIFICATION TO APPROVED SET - CHANGE OF FIXTURES(((PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE FROM RETAIL TO RESTAURANT. OCCUPANY LOAD EXCEEDS 99.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72456	12041-20000-04285	15630 W VENTURA BLVD	91436	5	168B141   685	2283006001	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			02/27/2012 12:00:00 AM	03/29/2012 12:00:00 AM		Permit Finaled	01/12/2016 12:00:00 AM	ADDRESS	34.15484	-118.47446	Upgrade utitlity service to 1200A.  New switchboard and replace subpanels.  New lighting for office tenant only (Fresh and Easy Market lighting is not part of this plan check).  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72457	13041-10001-30818	13192 N FENTON AVE	91342	7	225B157   793	2512015021	R1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.31014	-118.42108	Expedited RSES plan check per applicant request. PV1, Install 7.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Fronius IG Plus V 7.5. 30 modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72458	13041-10001-01737	785 N VIGNES ST	90012	14	132A217   391	5409025***	ADP, [Q]M3-1	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			04/10/2013 12:00:00 AM			PC Approved	04/10/2013 12:00:00 AM	ADDRESS	34.05606	-118.23248	PLAN CHECK FOR POWER. NEW ADDITIONAL 1000KW EMERGENCY GENERATOR, UPGRADE EXISTING EMERGENCY GENERATOR, ELECTRICAL CONNECTION ROOF TOP EQUIPMENT FOR EXISTING LACMTA UNION STATION HIGH RISE BUILDING. 455' bus duct((   4-10-13  Transfering existing EOC bus Duct tap from  existing normal bus way to a new bus way. no load change.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72459	17041-20001-18542	18518-18538 W LANARK ST	91335	12	189B125   165	2103009039	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM			PC Approved	03/02/2018 12:00:00 AM	ADDRESS	34.21735	-118.5372	03/02/2018 Changes to an approved set of plans. Location of PV equipment has changed. PV system size has remained the same.*****Previous Work Description*****pv2install roof mounted pv system sized 9kw interconnected with msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72460	14041-20000-09068	15355 W SHERMAN WAY # U,V,W	91406	6	183B145    36	2222027039	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			04/07/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.20139	-118.46803	TI for 1900 s.f. restaurant (La Sirenita Mexican Grill) in commercial shopping center.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72461	16041-10001-29603	8400 N BALBOA BLVD	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM			PC Approved	03/29/2018 12:00:00 AM	ADDRESS	34.22376	-118.50243	PC FOR REVISIONS TO APPROVED SET TO RELECT FIELD CHANGES. SCOPE INCLUDES ADDITION OF LIGHTING SWITCHES TO POOL AND LOBBY(CLOUDED ON THE PLAN)THIS IS A PLAN CHECK ONLY. PERMIT WAS PAID UNDER MASTER. **PROPOSED (1) STORY 37,000 SF FITNESS CENTER; PROJECT WILL CONSIST OF AREAS FOR WEIGHT TRAINING, CARDIO, CIRCUIT TRAINING, BASKETBALL COURT, AEROBICS, CYCLING, LAP POOL, RESTROOMS, LOCKER ROOMS, KID'S KLUB AND PERSONELLL TRAINING AREA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72462	18041-10000-35919	4363 S LINCOLN BLVD	90292	11	105B153   114	4229018026	[Q]C4(OX)-2D-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	33.98406	-118.44262	PLAN CHECK FOR TITLE 24 ONLY FOR - NEW ATTENDANT BOOTH FOR A NEW SURFACE PARKING LOT.   TOTAL AFFECTED AREA = 36395 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72463	13041-10000-04085	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00, 2657.00	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	04/18/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.06725	-118.41704	PLAN CHECK FOR INSTALLATION OF SIDESTREAM OZONE DOSING SYSTEM FOR IRRIGATION SYSTEM IN EXISTING STRUCTURE. NON HAZARDOUS AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72464	15041-20000-35263	15207 W SUNSET BLVD	90272	11	129B129   809	4423016073	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			10/21/2015 12:00:00 AM			PC Info Complete	10/21/2015 12:00:00 AM	ADDRESS	34.04647	-118.52446	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (BANK). SCOPE INCLUDES NEW LIGHTS AND ONE NEW SUBPANEL. TOTAL AREA IS 3495 SQ. FT.Note: Permit is pulled under PCIS#16041-10000-31749	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72465	19041-30000-29881	505 N MARINE AVE	90744	15	030B205  1037	7418004009	[Q]RD1.5-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Apartment			08/01/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	08/24/2021 12:00:00 AM	ADDRESS	33.7759	-118.2636	PC for New FA system For new 2-story apartment building. 1-FACP and 45-devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72466	16041-10000-08800	1677 W 251ST ST	90710	15	036B193    89	7410018018	R2-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	03/16/2016 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	33.79687	-118.3069	PV1, rooftop solar installation 1.72 kW    (8) HiS-M250MG    (8) M215-60-2LL-S22-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72467	19041-10000-04407	11700 N CORBIN AVE	91326	12	216B113     1	2701002068		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/06/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Issued	05/30/2019 12:00:00 AM	ADDRESS	34.28162	-118.57177	Title 24 plan check.  Installation of private tract site lighting in new development(Tract No 50509).  Lighting area = 395,628 Sq. Ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72468	16041-20001-06895	4812 E HILLSDALE DR	90032	14	144A231   314	5213004008	[Q]RD3-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2012.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM			PC Approved	11/17/2016 12:00:00 AM	ADDRESS	34.08718	-118.18138	11/17/2016 Changes to an approved set of plans. System size is now 5 kWac. Module count has not changed. New standard plan has been filled out.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (13) modules. Standard plan is being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72469	16041-10000-45645	10250 W SANTA MONICA BLVD # 1785	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Approved	02/28/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""SAJE"".  Install new panels and its circuits, lights and receptacles. Total effected area: 9064 sq.ft. ."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72470	18041-20000-40168	18830 W PASEO NUEVO DR	91356	3	165B121   130	2177021005	RE11-1	South Valley	Encino - Tarzana	Tarzana	Yes	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.15137	-118.54416	Plan check for PV roof mounted system, system size: 10.56kW with 32 PV Modules and 32 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72471	16041-20001-09449	14319 W ADDISON ST	91423	4	171B153   730	2248008035	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Apartment			03/17/2016 12:00:00 AM			PC Approved	03/29/2016 12:00:00 AM	ADDRESS	34.16175	-118.44496	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.6 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72472	14041-10001-24504	6912 N RANCHITO AVE	91405	2	183B153   822	2216019020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.1963	-118.43552	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 6.885 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(27 ) MODULES: KYOCERA  KD255GX-LFB3(1) INVERTE(S): SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72473	10041-20000-11472	1147 N BENTON WAY	90026	13	141A205    86	5402001001	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			06/16/2010 12:00:00 AM	09/21/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.08187	-118.26967	Plan check for 2.1KW Photovoltaic System for apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72474	13041-10000-32000	1556 W PALOS VERDES DR NORTH UNIT 1- 76	90732	15	030B193   207	7442001919	OS-1XL, RD6-1XL	Harbor	Wilmington - Harbor City	Northwest San Pedro	YES	9800.15	Electrical	Electrical	Apartment			11/27/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	33.7755	-118.30131	PLAN CHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO LEGALIZE APARTMENT BUILDING CONSTRUCTED UNDER FEDERAL GOVERNMENT EXEMPTION TO AFFORDABLE HOUSING COMPLEX. 15 TOTAL BUILDINGS WITH 71 UNITS. ( 15 SEPERATE PERMITS TO BE ISSUED AFTER PC), MZ.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72475	19041-10000-02195	333 S HOPE ST 54th Floor	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	TENANT IMPROVEMENT TO THE 54TH FLOOR. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.BUILDING PERMIT: 18016-10000-38166.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72476	14041-10000-28524	12746 W JEFFERSON BLVD	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Info Complete	07/08/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	PV2 144KWdc. 480V. xmfrLESS/Ungnd. NONstd. ???story. Roofmount. [(6) inverters: {SMA Sunny Tri-power 24000TL}]. [(684)modules: {JA Solar JPA6 72-305}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72477	10041-20000-04562	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005019	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM	05/25/2010 12:00:00 AM		Permit Finaled	08/17/2010 12:00:00 AM	ADDRESS	34.15303	-118.39667	Plan check power to temporary trailers at Campbell Hall school. Circuits in trailers are by others.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72478	18041-20001-32117	14729 W ROUND VALLEY DR	91403	4	162B149   116	2276034030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2018 12:00:00 AM			PC Approved	08/25/2018 12:00:00 AM	ADDRESS	34.14374	-118.45309	Expedited plan review.  (((PV1.  Install 6.22 kW DC/6.06 kW AC-CEC roof mounted grid tied PV system.  27 kWh energy storage system.  (20) modules with microinverters.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72479	19041-10002-06440	445 S FIGUEROA ST 21st floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.05295	-118.25675	PC to an approved set , T-24 only, change is marked delta 2. change include removing scon light and adding 1X4 lts in the corridor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72480	12041-10000-23833	11351 N DRONFIELD AVE	91331	7	210B165     6	2532009009	A2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.27673	-118.4036	Plan check power and energy for new K-2 primary school (charter school) building. Building supplied with two 800A service. Special permission has been filed for multiple service laterals. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72481	11041-10000-07633	5200 N LANKERSHIM BLVD	91601	4	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	04/18/2011 12:00:00 AM		Permit Finaled	05/31/2011 12:00:00 AM	ADDRESS	34.16511	-118.37448	T.I. TO AN EXISTING OFFICE BUILDING.  T-24 WITH EMERGENCY LIGHTING, OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72482	17041-10001-46484	552 W 121ST ST	90044	15	084B201  1346	6117005002	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	33.92239	-118.28476	PC FOR REVISION TO APPROVED SET. SCOPE INCLUDES RELOCATION OF PV BACKFEED BREAKER TO AN OUTDOOR SUB-PANEL. THIS IS PLAN CHECK ONLY! PERMIT FOR NEW PANEL PULLED SEPEARTLY. NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 11 MODULES ( HANWHA Q-CELL. Q PEAK-G4.1 305), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS) WITH A CENTRAL INVERTER (SOLAR EDGE SE3000H-US). SYSTEM SIZE IS 3.355 KWdc AND 3KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72483	15041-10000-31906	1565 W SEPULVEDA BLVD #5544	90501	15	045B193   504	7347017069	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			09/25/2015 12:00:00 AM			PC Approved	09/25/2015 12:00:00 AM	ADDRESS	33.81599	-118.30556	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ANF EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1229	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72484	15041-20001-11895	12457 W OSPREY LANE unit 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	ADDRESS	33.97937	-118.41024	Expedite per applicant request********Plan check for PV1 roof mounted  system 8 modules (SUNPOWER MODULES SPR-230NE-LK-D) and 1 inverter(SB3000TL -US-22)PV clearance shall be relavent to Unit #1 of address 12457 Osprey Lane	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72485	13041-20000-23733	5858 W ABERNATHY DR	90045	11	099B169   101	4105006013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	33.97081	-118.38396	PV1 TRANSFOMERLESS SYSTEM. 27 MODULES AND 2 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72486	19041-20000-41027	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72487	19041-10000-53869	1540 S GENESEE AVE	90019	10	129B177  1124	5069009024	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.04792	-118.36418	plan check for a pv system, system size 2.943 kw, 9 modules with a microinverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72488	15041-10001-01077	12558 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	33.97812	-118.41195	(3/3/2015) CHANGES TO AN APPROVED SET OF PLANS.  CHANGE FROM UNDERGROUND SERVICE TO OVERHEAD SERVICE.  DELTA ONE REFLECT THE CHANGES DONE ON THE PLANS.Plan check for power and energy for residential Condo project consisting of (7) 4-story, 6 unit building and the associated Site Lighting for the Project. 600Amps Service for all 6 units of the building with 1 house panel(Common area for the tenant). Fire alarm variance submited.Note: This application is part of 7 condo buildings submitted as 1 plan. 15041-10000-01075 (12526 W Fielding Cir), 15041-10000-01076 (12518 W Fielding Cir), 15041-10000-01072 (12534 W Fielding Cir), 15041-10000-01067 (12542 W Fielding Cir), 15041-10000-01050 (12550 W Fielding Cir), 15041-10000-01077 (12558 W Fielding Cir), 15041-10000-01070  (12510 W Fielding Cir)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72489	14041-10000-04466	2723 W 8TH ST	90005	1	132A201    11	5077020802	[T][Q]C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	ADDRESS	34.05787	-118.28484	CHANGE OF USE; EXISTING 2-STORY RETAIL OVER PARKING TO CHARTER SCHOOL.BUILDING PERMIT 14016-10000-02954	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72490	18041-10000-03937	923 E 3RD ST # 111	90013	14	129A217   170	5163006016	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04611	-118.23427	REPLACE INDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72491	18041-10000-26977	3780 S WATT WAY	90089	9	117B197   224	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	PIN	34.01877902	-118.28765493	NEW FIRE ALARM SYSTEM WITH 159 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72492	17041-10000-37904	5271 W SANCHEZ DR	90008	10	117B177   348	5029005016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	10/23/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.01545	-118.35992	Plan check for PV roof mounted system. System size: 11.4kW-AC with 36 modules(11.5kW-DC) and 1 inverter(11.4kW-AC)	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72493	17041-20000-18798	10250 W CONSTELLATION BLVD 30th Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.05735	-118.41746	Plan check for Title 24 only. Project site is a portion of the 30th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,290 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72494	17041-10000-04642	20111 W RINALDI ST BLDG S6	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.27542	-118.57218	PC FOR POWER AND ENERGY. NEW BUILDING S5 - SHELL ONLY COMMERCIAL BUILDING, 1 STORY, SERVICE 600A 277/480 V, TOTAL AREA 2819 SQ FT.B# 16010-10000-06146	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72495	19041-20000-39466	87 S FREMONT PL	90005	4	132B185   621	5090016008	RE11-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2019 12:00:00 AM	10/01/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.05658	-118.32867	Installation of 13.5 kWh energy storage system.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72496	14041-20000-34761	1515 W 190TH ST Suite 510	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	33.85852	-118.30531	Plan check for power and energy. CHANGE OF USE FROM (E)  OFFICE TO MEDICAL OFFICE AND INTERIOR NON-STRUCTURAL TENANT IMPROVEMENT. New lighting (incl. emergency) and rewiring of circuits in patient care areas. Emergency lighting connected to emergency generator circuit. Reusing existing circuits, no change in load. Exam rooms require redundant grounding.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72497	14041-20000-10264	14822 W ARCHWOOD ST	91405	6	180B149   146	2236004016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.05	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.19276	-118.45597	pv1 single family dwelling. total system size 3.4 kw ac using enphase microinverter. nonstandard plan. 16 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72498	14041-20000-29237	9332 N BRIGHTWOOD CT	91325	12	198B133   227	2692022005	RE9-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Expired	11/15/2016 12:00:00 AM	ADDRESS	34.24034	-118.50309	PV1Using standard plan. Two 3kW ungrounded inverters for a system size of 6kW. 31 255W pv modules across 4 strings. Two strings per inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72499	14041-20001-11520	10727 N OVERMAN AVE	91311	12	207B109   189	2707004029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM			PC Approved	05/22/2014 12:00:00 AM	ADDRESS	34.2659	-118.57797	EXPEDITE PER CUSTOMER REQUEST.PV1 INSTALL ROOF MOUNTED PV SYSTEM SYSTEM SIZED AT 11.75KW INTERCONNECTED WITH MAIN PANEL USING (2) TRANSFORMERLESS INVERTERS, POWER-ONE PVI 6000, POWER-ONE PVI 5000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72500	15041-10001-13555	1906 S CRENSHAW BLVD	90018	10	126B185  1011	5060006010	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.01	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	PIN	34.03954244	-118.3309683	Supplemental PC only . T-24 for outdoor lighting at Jack in the Box 3377. Total area: 23,287 sq. ft. Permit under 15041-10000-13555.***REPLACING EXISTING EXTERIOR LIGHTS AND PARKING LOT LIGHTS W/LED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72501	16041-10004-25961	300 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/07/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	33.94502	-118.40714	CHANGES TO APPROVED SET.  ADDITION OF NEW CIRCUITS AND CHANGES TO LIGHTING PLAN.  TITLE 24 UPDATED.  SCOPE OF WORK IS CLOUDED WITH DCN-028.  NEW BUS GATE AND FACILITY IMPROVEMENT FOR TERMINAL 3 TO SUPPORT NEW DELTA AIRLINES NETWORK, BUSING OPERATION, AND OFFICE RENOVATION.BUILDING PLAN CHECK #16016-10000-11866	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72502	19041-20000-42424	13263 W SEVILLANA WAY	91342	7	225B157  1047	2510026012	(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.31547	-118.42243	Plan check for PV roof mounted system, PV System size: 1.68KW with 7 PV Modules and 7 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72503	18041-20002-16642	13271 N GLENOAKS BLVD	91342	7	225B149   332	2505001029	R1-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2018 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.31207	-118.45576	06-18-2018 Changes to an approved set of plan. Changes include change of conductor size. Changes has been clouded. Plan check only.Fees $0 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72504	14041-20002-02295	1017 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197    80	5037026017	P-1, [Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM			PC Approved	07/25/2014 12:00:00 AM	ADDRESS	34.01107	-118.29267	Feeder changes to office panel SA.  Does not affect scope of original plan check - for energy only.  Supplemental plan check per applicant request.  T24 FOR EXISTING COIN LAUNDRY. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72505	19041-10001-18098	1218 S HOOPER AVE	90021	14	121-5A213 143	5130024016	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	34.02705	-118.24253	UPDATED SINGLE LINE DIAGRAM TO SHOW CIRCUIT BREAKERS DOWNSTREAM FROM THE MAIN DISCONNECT ARE NEW AND ADDED MANUFACTURER'S INFORMATION SHEETS FOR THE NEW CIRCUIT BREAKERS(((((((PC FOR CULTIVATION FACILITY (CHANGE OF USE).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72506	15041-10000-14256	17260 W LAHEY ST	91344	12	210B133   399	2697006012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM			Reviewed by Supervisor	05/19/2015 12:00:00 AM	ADDRESS	34.27291	-118.50979	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72507	19041-10000-11973	13130 W BURBANK BLVD	91401	4	174B157  1137	2345005028	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.17191	-118.41936	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72508	09041-20004-24723	15301 W LANARK ST	91406	6	189B145    41	2654037029	R4-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Apartment			10/12/2012 12:00:00 AM			PC Approved	10/12/2012 12:00:00 AM	PIN	34.2183683	-118.4669973	Modification to feeder sizes based on use of optional load calculation 220.82.  The maximum name plate rating of the electrical ranges to be installed shall not exceed 8000 watts.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72509	16041-20000-18795	12811 W SHERMAN WAY	91605	2	183B161     9	2324005033	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	34.20135	-118.41209	PLANCHECK FOR T24 ENERGY PER INSPECTORS REQUEST.  ROYAL MARKETPLACE. 1070 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72510	13041-10000-03823	23333 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	05/28/2013 12:00:00 AM	ADDRESS	34.15724	-118.63407	Plan check for power and energy. Tenant improvement in existing medical office (The Joint- Chiropractic Place). No change of use.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72511	17041-20003-09885	12601 W PIERCE ST 45, 46	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			12/27/2018 12:00:00 AM			PC Approved	12/27/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	SUPPLEMENTAL CHANGES TO REFLECT FIELD CONDITIONS  UNDER DELTA 2 ONLY. PLAN CHECK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72512	19041-20000-12424	7600 N BALBOA BLVD ev 3	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			04/05/2019 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	addition of (6) EV chargers to to an existing 1200 amp distribution board.  plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72513	14041-10000-22324	1233 W 255TH ST	90710	15	036B197   728	7413005017	[Q]M1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	33.79291	-118.29868	"permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. NO: 123810  -- Building/Electrical/Mechanical""COMPLY WITH DEPARTMENT ORDER effective date07/29/2014. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".Investigation waived for this application per inspector."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72514	13041-10000-35003	21701 W VENTURA BLVD	91367	3	174B105    62	2168027030	(T)(Q)C4-1L	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	03/24/2014 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	PIN	34.16899731	-118.60037995	PLAN CHECK FOR POWER AND ENERGY FOR CONSTRUCTION OF A NEW AUTOMOTIVE SALES, SERVICE, PARTS AND PARKING FACILITY. DESIGN BUILD BY GENERAL CONTRACTORS.BUILDING PERMIT # 13010-10000-04092	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72515	13041-10001-34464	6344 N TOPANGA CANYON BLVD	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	06/16/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	Changes to an approved set of plans. Changes include relocating load circuits. No new circuits or panels added. All changes are clouded. Approved for submittal per F.Y.*****Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL. WESTFIELD MALL. BUILDING A. BUILDING PERMIT # 13010-10000-02904New retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72516	17041-20001-19995	1052 N HANLEY AVE	90049	11	138B137    28	4493018003	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.07809	-118.49039	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72517	16041-20002-25960	1255 N BUNDY DR	90049	11	141B141   159	4493028021	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.08224	-118.48357	8.25.2016 - Panel layout on roof updated. Restamp plan.FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.=====Plan check for PV roof mounted system. System size: 11.7kW with 41 modules and 41 microinverters(Enphase)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72518	17041-20000-02960	15910 W VENTURA BLVD Ste 1120-1150	91436	5	168B141   631	2283010029	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/30/2017 12:00:00 AM			PC Approved	01/30/2017 12:00:00 AM	ADDRESS	34.15561	-118.47969	TI to (E) commercial office in highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72519	16041-20001-42799	5958 N CALVIN AVE	91356	3	177B117   678	2153034015	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.17897	-118.55548	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system roof-mounted on SFD. Interconnect with a 200A MSP. Derating the main to 150A. 14.31kW ungrounded system.  (53) EnPhase S280 microinverters (53) 320W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72520	12041-20000-15937	5228 N LUBAO AVE	91364	3	171B113   175	2164005031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2012 12:00:00 AM	07/30/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.16592	-118.56675	New roof mounted P.V. system with 10.29 KWdc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72521	10041-20002-19382	10351 W SANTA MONICA BLVD 410	90024	5	132B157   476	4327007016	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM			PC Approved	12/06/2010 12:00:00 AM	PIN	34.0585564	-118.42324002	Plan check only for T-24 Energy (general/emergency) lighting revision to approved plans. Permit under #10041-90000-19382.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72522	19041-10000-30507	6600 N TOPANGA CANYON BLVD FC1	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			08/06/2019 12:00:00 AM	08/21/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	ENERGY PC ONLY FOR REMODEL EXISTING FOOD COURT TENANT IN AN (E) MALL. AREA OF SCOPE 110SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72523	16041-10000-36597	1262 E 40TH PL	90011	9	115-5A211 177	5114035011	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2282.10	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Expired	09/10/2023 12:00:00 AM	ADDRESS	34.01008	-118.25278	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(12)MODULES-AXITEC AXIPOWER AC-265/156-60S(1)INVERTER-FRONIUS PRIMO 3.8	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72524	16041-20000-01454	7141 N ALABAMA AVE	91303	3	183B105   240	2111027015	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.20033	-118.59915	Plan check for Service upgrade 600A commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72525	19041-20000-21781	22819 W LEONORA DR	91367	3	171B097   249	2042015016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2019 12:00:00 AM	06/07/2019 12:00:00 AM		Permit Finaled	07/02/2019 12:00:00 AM	ADDRESS	34.16702	-118.62395	PV1.  Install 8.78 kW DC roof mounted grid tied PV system.  (27) modules with 7.7 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72526	12041-10000-11214	700 S FLOWER ST #1800	90017	9	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	34.04835	-118.25882	T.I. to an existing office building.  Load is less than 400A per applicant.  Applicant will be doing multiple jobs on separate plan checks -  subject to field inspection,  if total load of separate jobs is greater than 400A a Full Plan Check may be required, even for signed off portions.   PLAN CHECK ONLY for Energy, with Emergency lighting.   Permit fees for new circuits are under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72527	12041-10000-24589	6648 N BAIRD AVE	91335	3	180B125   281	2126038037	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	01/22/2013 12:00:00 AM	ADDRESS	34.19168	-118.53752	PV1 - PLAN CHECK 4.32KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING AURORA TRANSFORMERLESS INVERTER - 2 STRINGS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72528	13041-10003-05741	380 WORLD WAY space T71	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	33.94373	-118.40888	CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES IN THE T24 ONLY, REPLACING TYPE LF-02 AND LF-10  LUMINAIRE TO BE ETL APPROVED LUMINARIES PER INSPECTORS REQUEST.changes to approved set of plans: relocate 150kva xfrmr. changes to kitchen layout. revision 14. added exhaust fan. hood equipment. delta 9 under previous supplemental. original description: PROPOSED 6,092 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (III FORKS).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72529	16041-10003-36064	401 S KENMORE AVE	90020	10	135B197   511	5502013009	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.10	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.06702	-118.29683	EXTENDING SCOPE OF WORK TO INCLUDE LIGHTING REVISION IN COMMON AREA (HALLWAY). PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED UNDER THIS APPLICATION FOR ADDITIONAL LIGHTING WORK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72530	16041-20001-02411	7709 W FOOTHILL BLVD	91042	7	204B197   640	2558008015	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM			Reviewed by Supervisor	02/03/2016 12:00:00 AM	ADDRESS	34.25695	-118.3002	Expedited per customer service.PV2. System is being installed on a commercial building (medical). Install roof mounted PV system sized 6 kW. Interconnected with main service panel. (27) SolarWorld SW285 Modules(27) Solaredge P-400 Power Optimizers(1) Solaredge SE 6000 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72531	13041-10000-17151	6142 W 75TH ST	90045	11	102B165   745	4106005020	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2013 12:00:00 AM	07/03/2013 12:00:00 AM		Permit Finaled	08/06/2013 12:00:00 AM	ADDRESS	33.97305	-118.39345	PV1 3.24kw MICROINV ? STORY. STD. ROOFMOUNT.[ 15 MICRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: 15conergy PE 255 watt modules]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72532	12041-20000-03395	8985 W VENICE BLVD	90034	10	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	34.02733	-118.39241	"Change of use from retail space to restaurant.  T-24 lighting plan check for  restaurant.  Load is less than 400 Amps.  Occupancy load is 39, per applicant.  Permit Fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72533	13041-10000-16512	112 S CORONADO ST 1-5	90057	13	136-5A203 164	5155035002	R3-1	Central	Westlake	Greater Echo Park Elysian	YES	2085.02	Electrical	Electrical	Apartment			06/21/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.06859	-118.276	FA FOR APT 3 STORY. 25 devices and 1 panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72534	14041-10000-00287	19759 W RINALDI ST	91326	12	210B117   409	2701040039	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	10/24/2014 12:00:00 AM	ADDRESS	34.27504	-118.56375	PLAN CHECK FOR POWER AND ENERGY . TI OF STARBUCKS. EQUIPMENT RATED 600AMPS.BUIDLING P# 13016-20000-26394	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72535	13041-10000-35372	2310 S GLENCOE AVE	90291	11	111B149  1063	4242034018	R1-1VLD	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Expired	04/04/2016 12:00:00 AM	ADDRESS	33.99797	-118.44804	PV1, Install 3 kW DC roof-mounted solar array, interconnect with main service panel for a house. (1)Transformerless inverter: Solaredge SE 3000A-US. (12) modules YINGLI YL250P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72536	15041-10000-33858	20350 W VENTURA BLVD	91364	3	171B113    28	2166035030	(Q)CR-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	11/09/2015 12:00:00 AM		Permit Finaled	04/19/2016 12:00:00 AM	ADDRESS	34.16881	-118.57601	PERMIT FEES $0.00 BY STATE SENATE BILL NO. 1222PV2, ROOF MOUNTED SOLAR SYSTEM TO AN (E) OFFICE BUILDING. (160) MODULES AND (6) INVERTERS. (160) CANADIAN SOLAR CS6X-315P(3) SMA SUNNY BOY SB900TL-US(3) SMA SUNNY BOY SB7000TL-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72537	13041-20001-27292	25965 S NORMANDIE AVE 2nd floor-3rd floor	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM			PC Approved	02/28/2014 12:00:00 AM	ADDRESS	33.78734	-118.29768	(((CHANGES MADE TO APPROVED SET OF PLANS. THIS IS A PLAN CHECK FOR ENERGY ONLY. SWITCHED OUT ONE FIXTURE TYPE FOR ANOTHER)))Replace/retrofit lighting on the 2nd and 3rd floors.  No new loads or circuits.  Kaiser Medical Building.  PLAN CHECK ONLY for Energy with Emergency lighting. {{INSPECTOR TO VERIFY THAT THERE IS NO WORK IN PATIENT CARE AREAS}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72538	15041-10000-23965	6460 W 83RD ST	90045	11	099B165  1148	4108011005	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	33.96362	-118.40128	PV1ROOF MOUNTED PV SYSTEM SIZED 5.0KW INTERCONNECTED WITH MSP. (24) MODULES. KYOCERA MODEL: KU2656ZPA (1) INVERTER SIZE: 5.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72539	14041-10001-04684	5148 E LINCOLN AVE	90042	1	154-5A225  15	5478007002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM			PC Approved	03/01/2014 12:00:00 AM	ADDRESS	34.11968	-118.2033	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.[{PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(18) MODULES:  CNADIAN SOLAR CS6P-250PX}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72540	18041-10001-02653	7681 W WILLOW GLEN ROAD	90046	4	153B173    75	5569001003	RE11-1	South Valley	Hollywood	Hollywood Hills West	Yes	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2018 12:00:00 AM			PC Approved	02/27/2018 12:00:00 AM	ADDRESS	34.11872	-118.36855	Voidednew SFD with 600 amp service,  Building permit is issued under combined 16010-20000-00614.   Permit for this job to cover service only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72541	17041-10001-04385	1999 S AVENUE OF THE STARS SUITE 200	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Approved	05/04/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	Changes to approved set.  Remove controlled receptacles.  Title 24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72542	11041-10000-10936	151 N WESTERN AVE	90004	4	138B193   802	5517003017	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			05/27/2011 12:00:00 AM			PC Approved	05/27/2011 12:00:00 AM	ADDRESS	34.07445	-118.30931	T.I.  Installing new lighting fixtures in an existing restaurant.  Plan check is for lighting and emergency lights.  Title-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72543	17041-20001-41495	20533 W DEVONSHIRE ST	91311	12	204B109   127	2707013030	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	34.25742	-118.58061	12.11.2017 - Plan check for energy only. TI/Change of use from retail to massage. 1,392sqft. Permit fees collected under parent application #17041-90000-41495.======Replace a light switch	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72544	18041-20000-22802	5750 W WILSHIRE BLVD 4th Floor	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.06227	-118.3542	Plan check for power and energy T.I. office space new lighting and receptacle newly connected load exceed 400A. Total area: 28503 sq ft. B#18016-10000-18303	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72545	16041-10000-12530	1800 CENTURY PARK EAST	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/11/2016 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	11/20/2017 12:00:00 AM	PIN	34.06231391	-118.41444108	PC FOR GYM ON ROOF LEVEL. HIGH RISE BUILDING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72546	15041-20000-19905	722 S HARTFORD AVE	90017	1	130-5A205 221	5143009006	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Apartment			06/24/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	34.05143	-118.2676	REPLACE FEEDERS AND SERVICE IN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72547	18041-20000-29344	21600 W OXNARD ST Suite 850	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	11/08/2018 12:00:00 AM	ADDRESS	34.179	-118.6002	Plan check for Title 24 only. Project site is a suite in an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,645 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72548	12041-10000-17815	4401 W SUNSET BLVD	90027	4	147A201   109	5542009027	M1-1, [Q]C2-1	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM	10/17/2012 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.09708	-118.28526	PLAN CHECK POWER AND ENERGY FOR NEW SPRAY ROOM IN EXISTING BLDG. WIRING IN HAZARDOUS AREA. CLASS I DIV II.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72549	19041-20000-05383	11633 W KLING ST	91602	2	168B169   671	2354017012	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Issued	02/14/2019 12:00:00 AM	ADDRESS	34.1559	-118.38662	Plan check for PV roof mounted system, sytem size: 13.68KW, 11.4KW AC with 38 PV Modules and 1 inverter(11.4KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72550	14041-10009-15889	5875 W INTERCEPTOR ST	90045	11	096B169  1125	4125009197	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	ADDRESS	33.95605	-118.38499	REROUTING  OF SERVICE CONDUCTORS FROM UTILITY TRANSFORMERS TO SWITCHBOARDSMSB AND MSC AT LEVEL P1 BY ENCASING IN CONCRETE. ALL CHANGES HAVE BEEN DONE UNDER DELTA 11 - TOP HATS AND MC CABLE SHALL BE FIELD ISPECTED FOR LISTING TO BE USED WITH CONCREATE AND DISTRIBUTION EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72551	14041-20000-33269	13902 W HAMLIN ST	91401	2	180B153   857	2238023012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	04/07/2015 12:00:00 AM	ADDRESS	34.18831	-118.43584	PV1Using standard plan.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.Derating main breaker from 200A to 175A.System size: 7.2kW (inv1 - 4.2kW; inv2 - 3kW). Ungrounded system.37 255W pv modules across 4 strings (inv1 - 13+10; inv2 - 6+8).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72552	17041-10000-38580	2023 S UNION AVE	90007	1	124-5A201  82	5124002021	[Q]C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	01/17/2018 12:00:00 AM	ADDRESS	34.03665	-118.28252	PLAN CHECK FOR T24 ONLY, REMODEL RECEPTION AREA, INSTALL NEW LIGHTS AND RECEPTACLES, TOTAL AREA 619 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72553	13041-20000-29395	3165 S BARRY AVE	90066	11	117B153    28	4250009030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	04/17/2014 12:00:00 AM	ADDRESS	34.02077	-118.43566	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM 3.456KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72554	19041-10000-11511	137 N VIRGIL AVE	90004	13	138B197   658	5501007027	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Permit Finaled	03/23/2020 12:00:00 AM	ADDRESS	34.07469	-118.28704	Full plan check for a Change of use of first floor of (E) office/adult day care building to first floor OSHPD-3 primary care clinic, dental and medical clinic (outpatient) and administrative offices. Scope includes new panels, equipment, lighting and receptacles. total affected area is 14132 sq.ft B#19016-10000-07457	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72555	14041-10000-13989	1001 N ENCHANTED WAY	90272	11	132B121   490	4419003018	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	08/19/2014 12:00:00 AM	ADDRESS	34.05479	-118.54922	5.2 kW solar PV roof mounted with microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72556	16041-10000-15028	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	PIN	33.94094587	-118.40577128	TI TERMINAL 3 IT ROOMS. FULL PLAN CHECK WITH TOTAL AREA 1690 SQFT. pc engineer to review fees, applicant has premade check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72557	18041-10000-31818	2140 W OLYMPIC BLVD	90006	1	130-5A201 166	5136013023	C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.05183	-118.28061	NEW FIRE WARNING SYSTEM FOR A COMMERCIAL BUILDING; A REMOTE POWER SUPPLY UNIT IS INSTALLED ON EACH FLOOR  TO SUPPLY INITIATING DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72558	15041-10001-41316	7100 N HAYVENHURST AVE	91406	6	183B137   146	2224017022	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/16/2016 12:00:00 AM			PC Approved	03/17/2016 12:00:00 AM	ADDRESS	34.19917	-118.49222	03/16/16Changes to an approved set of plans. All changes are made under delta 3. Changes include PV point of connection changing from supply side to load side of existing switchboard. NOTE: Permit pulled under PCIS#15041-10000-41316((((($0 FEE PER SENATE BILL 12222.<<PV2, ROOF MOUNTED SYSTEM TO A COMMERCIAL BUIDLING. 320 MODULES AND 3 INVERTERS, TOTAL SIZE 84KW-AC. (320) SOLAR WORLD 320 XL MONO(3) SOLECTRIA-PV1 28TL>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72559	16041-10002-06514	11401 W SANTA MONICA BLVD	90025	11	129B149   513	4261003009	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			02/15/2019 12:00:00 AM			PC Approved	02/15/2019 12:00:00 AM	ADDRESS	34.04602	-118.4512	DELTA CHANGES TO APPROVED PLANS FOR SERVICE LAYOUT AND RE-CALCS OF FEEDER SIZES. REDUCED CONNECTED LOAD.  (PER - MZ)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72560	19041-30000-24324	3921 W WILSHIRE BLVD	90010	10	132B193    32	5504028***	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2117.04	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	11/04/2019 12:00:00 AM		Permit Finaled	11/20/2021 12:00:00 AM	ADDRESS	34.06188	-118.31234	PC FOR FA SYSTEM CONSIST OF 1 FACP AND 420 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72561	13041-10000-22719	120 S LOS ANGELES ST	90012	14	130-5A213  98	5161016027	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/21/2013 12:00:00 AM			PC Approved	08/21/2013 12:00:00 AM	ADDRESS	34.05092	-118.24262	Interior remodel to kitchen serving hotel.  Title 24 plan check only for lighting.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72562	16041-20002-10517	19524 W NORDHOFF ST #11	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.23527	-118.55871	8.16.2016 - Plan check for modifications to approved set. Replacing Leviton current limiter panel with 1A Lithonia current limiters on each track. Updated T-24 forms to reflect change. Delta 3 changes.====7.19.2016 - Plan check for modifications to approved set. Update plan to correctly reflect existing service and panel configuration in tenant space. Change bathroom lighting control from dimmer switch to combined occupancy sensor and dimmer switch.====Plan check for energy only. Change of use from restaurant to music studio. New lighting (incl. emergency). 4,515sqft. Electrical permit pulled under permit #16041-20000-05567	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72563	13041-10000-30079	8561 N RESEDA BLVD	91324	12	192B125   101	2785006001	C2-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.22628	-118.5363	PLAN CHECK FOR TITLE 24 ENERGY ONLY. RESTUARUANT. 1 STORY. NO CHANGE IN OCCUPANCY. 956 SQFT. NO EMERGENCY LIGHTING REQUIRED ACCORDING TO APPLICANT. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72564	18041-20001-03395	7751 W VERAGUA DR	90293	11	099B153    56	4114002018	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	33.96509	-118.43308	05-29-2019 Changes to an apporved set of plans, changes include update drawing as built. Changes has been clouded as delta 1. Installed 2 Tesla PowerWall 2.0 (26.4kWh.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72565	17041-10002-12815	380-384 WORLD WAY MSC	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	12/10/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	CHANGES TO APPROVED SET OF PLANS - SCOPE INCLUDES ADDING NEW PANELS, MODIFYING POWER AND LIGHTING CIRCUIITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72566	13041-20000-25583	811 W 7TH ST 9TH FLR	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.04908	-118.25911	PC FOR T24 ENERGY ONLY. SMALL OFFICE AREA. WORK ON 9TH FLOOR. NEW LGIHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72567	19041-10000-14418	10059 N LAUREL CANYON BLVD	91331	7	204B157  1086	2646016024	[Q]C2-1VL	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.25291	-118.42624	PLAN CHECK FOR TITLE 24 ONLY - SCOPE INCLUDES CHANGING HID TO LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72568	16041-10001-37829	6275 N PENFIELD AVE	91367	3	177B113   341	2153036013	RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2016 12:00:00 AM			Verifications in Progress	01/06/2017 12:00:00 AM	ADDRESS	34.18499	-118.56776	expedite feesPV FOR PV SYSTEM 6.8KW AC USING BATTERY BACKUP SYSTEM. SYSTEM CONTAINS 24 modules. central inverter with built in charge controller. system uses 12 batteries to supply 48v DC. system includes installation of back up load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72569	10041-20000-01811	6940 N SEPULVEDA BLVD	91405	6	183B145   461	2220010038	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Apartment			02/02/2010 12:00:00 AM			PC Approved	02/02/2010 12:00:00 AM	ADDRESS	34.19691	-118.46592	REVISION TO APPROVED PLANS WITH PCIS #09041-20000-13704(122 kw photovoltaic system for 98  units apartment building). Changed point of connection for pv system due to electrical work added by others.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72570	14041-10000-04617	9031 N LURLINE AVE Bldg 7	91311	3	198B109   193	2780001058	(T)(Q)M2-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM	02/09/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.23463	-118.58443	pc for power and energy. bldg 7 (4of 4)14010-10000-00414 building description: NEW SPEC CONCRETE TILT UP INDUSTRIAL BUILDINGS; 1-STORY WITH MEZZANINE (BUILDING 7) OFFICE- 5,000 SQ.FT.; WAREHOUSE - 24,208 SQ.FT.HAVE APPLICANT VERIFY 20700 NORDHOFF ST. WITH B.O.E. ADDRESS COUNTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72571	17041-20000-14635	11600 N ANDASOL AVE	91344	12	213B129   154	2607008024	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.28148	-118.51251	Plan check for the addition of a PV1 roof-mounted PV system to an existing PV system. System size addition is 3 kWac and consists of (1) inverter and (9) modules. Total system size is 10.6 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72572	10041-10000-12017	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			06/23/2010 12:00:00 AM			PC Approved	07/02/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	New Fire Alarm system. Plan check for Power. (Permit is alredy issued # 10041-10000-05859)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72573	18041-10000-31151	3700 S LA BREA AVE	90016	10	117B177  1129	5046038025	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.02	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/17/2018 12:00:00 AM	ADDRESS	34.01929	-118.35537	First time occupancy in a new retail store. EPC for Power and Energy. Building Permit # 18016-10000-26290	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72574	19041-20000-06776	20600 W ROSCOE BLVD 5	91306	3	192B109   856	2108001033	(T)(Q)R3-1, (T)(Q)RD3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.03	Electrical	Electrical	Commercial			02/25/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.21987	-118.58192	Plan check for Title 24 only for temporary Sales Office in the Small Lot Subdivision. Total area: 409 sq ft. B#: 16010-20000-05961	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72575	18041-10000-13388	950 E 108TH ST	90059	15	088-5A209  57	6071017001	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2408.00	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM			PC Info Complete	04/12/2018 12:00:00 AM	ADDRESS	33.93815	-118.25692	PC FOR INTERIOR TI WORK AT EXISTING RESTROOMS, OFFICE AND LOUNGE SPACE  FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUTIS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 3007 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72576	17041-10000-04430	12785 W BLUFF CREEK DR	90094	11	102B161  1270	4211037026	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	33.97439	-118.41688	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 4 STORY, THREE UNIT CONDO APARTMENT BUILDING. SCOPE INCLUDE  59 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72577	17041-30000-19837	601 S FIGUEROA ST Suite 4625	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Issued	07/26/2017 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is a suite in a existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 5,445 sq. ft.Note: Building application has been generated under 17016-10000-14885	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72578	14041-20000-35226	12208 N DELANTE WAY	91344	12	219B125   107	2601074014	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM			Corrections Issued	01/05/2015 12:00:00 AM	ADDRESS	34.29569	-118.52793	PV1. Install roof mounted PV system sized 11.0 KW on sfd. Ungrounded system. Interconnected with 200A MSP.48 300W PV modules across 4 strings, 12 modules/string.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72579	18041-20002-41888	5623 N FAIRHAVEN AVE	91367	3	174B085    93	2046009016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/30/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.17276	-118.6582	Expedite per applicant request 11-30-2018 Changes to an permitted set of plans, change from microinverters to central inverter system, System size: 14.52kW, 12.342kW AC with 44 modules and 2 inverters(6.0kW and 10.0kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72580	15041-10001-43188	4219 S DALTON AVE	90062	8	114B193  1061	5021013012	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.00671	-118.30365	((2-2-16: CHANGES MADE TO APPROVED SET. RECONFIGURING MODULES AND TERMINATING AT NEW LOAD CENTER))PV1 for a residential home. Intalling 4.2 kw inverter, 18 modules, distrubution panel 125 Amps.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72581	13041-10000-03297	303 S PACIFIC AVE	90731	15	018B197  1575	7451018900	[Q]C2-1XL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Apartment			02/08/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Issued	11/12/2013 12:00:00 AM	ADDRESS	33.7413	-118.28819	NEW CONSTRUCTION OF 49 UNIT APARTMENT COMPLEX. PC FOR POWER AND ENERGY. TOTAL AREA OF 59267 SQ FT. APARTMENT ONLY, NON MIX USE. NOT methane. will pull permit for conduit only 13041-10000-27091 (conduit only variance filed on 9/30/13) tomorrow.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72582	16041-20000-37705	14914 W SHERMAN WAY	91405	6	183B149    87	2220005017	C1.5-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.20097	-118.45792	remove hid fixtures and replace with new led outdoors.  plan check for energy 104500 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72583	16041-20000-42216	3364 N STONERIDGE LANE	90077	4	159B149   307	2278032016	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.13187	-118.45838	"""0$ permit fees due to senate bill 1222""pv1install roof mounted pv system sized 15kw interconnected with msp, with battery backup 6kw."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72584	13041-20000-32360	2622 S LA CIENEGA BLVD PV2	90034	10	123B173  1992	5065012046	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			11/19/2013 12:00:00 AM	12/11/2013 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.03458	-118.37741	New 12.09kw rooftop commercial PV System for an existing commercial building.  System is negatively grounded.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72585	11041-20000-14640	5454 S BEETHOVEN ST 1ST FLR	90066	11	102B157    63	4211009001	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	33.97656	-118.42113	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR OFFICE TI FIRST FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72586	13041-20000-19264	15424 W SUNSET BLVD	90272	11	129B125   501	4412001017	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			PC Approved	08/21/2013 12:00:00 AM	ADDRESS	34.04806	-118.52795	Gelson's Supermarket.  Remodel of the Deli area and bakery.  Adding and relocating light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72587	13041-20001-20058	9635 N RESEDA BLVD	91324	12	201B125   288	2763002029	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	ADDRESS	34.24571	-118.5363	"((((CHANGES MADE TO APPROVED SET OF PLANS. SOME LIGHTS ELIMINATED AND SOME LIGHTS ADDED. THIS APPLICATION IS A PLAN CHECK ONLY.)))) Change of use from retail to restaurant.  Load is less than 400 amps.  Occupancy load is 49 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.  PERMIT FEES ARE UNDER INSPECTION.      ""COMPLY WITH DEPARTMENT ORDER effective date 06/26/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72588	19041-10001-46874	23526 W ELKWOOD ST	91304	12	189B093   549	2020006023	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.2125	-118.63986	EXPEDITE FEESPV1, NEW OOFTOP MPUNTED SYSTEM, SYSTEM SIZE IS 9.92 KWdc/7.6KWac. SCOPE OF WORK IS 32 MODULES (SNM310) WITH OPTIMZERS (SE P320). LEADING TO A CENTRAL INVERTER (SE 7600-US) WITH A BATTERY STORAGE SYSTEM (LG CHEM RESU10H). NO SERVICE PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72589	17041-20002-16704	23856 W STAGG ST	91304	12	189B089   448	2027040034	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.21056	-118.64918	Revisions to approved plans.  Change of equipment locations, wire sizes.  Approval for clouded changes only.    (((Plan check for a PV1 roof-mounted PV system. System size is 13.5 kWac and consists of (39) AC PV modules and (1) load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72590	12041-10000-17109	430 W 6TH ST	90731	15	015B201    89	7455004005	C2-1-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			07/23/2012 12:00:00 AM	11/28/2012 12:00:00 AM		Permit Finaled	04/25/2014 12:00:00 AM	ADDRESS	33.73887	-118.28643	UPGRADE SERVICE FOR A COMMERCIAL BUILDING TO 800A; add new panelboard ;reconnect existing AC units to panelboard.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72591	14041-20000-19063	7806 N LOMA VERDE AVE	91304	3	189B109   831	2109012012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.21232	-118.58946	PV1Install roof mounted solar array on SFD. System size: 5kW(1) Aurora UNO PVI-5000-TL-OUTD-S-US-A transformerless inverter(16) SPR-E20-327 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72592	12041-10000-17991	500 S VIRGIL AVE 505	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM			PC Approved	08/01/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	Plan check for energy and emergency lighting. Suite 505 of Hollywood Presbyterian Medical Center. Scope of work does not include critical care areas. 1320 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72593	15041-10000-27017	2011 N FIGUEROA ST	90065	1	141A219   669	5415001901	GW(CA)	East Los Angeles	Northeast Los Angeles	Greater Cypress Park, Greater Echo Park Elysian		1853.20	Electrical	Electrical	Commercial			08/18/2015 12:00:00 AM	02/09/2017 12:00:00 AM		Issued	02/09/2017 12:00:00 AM	PIN	34.08191672	-118.22563264	OUTDOOR LIGHTING FOR REBUILD OF CONFLUENCE PLAZA PARK.  PLAN CHECK FOR ENERGY AND EMERGENCY EGRESS ONLY. TOTAL SQUARE FOOTAGE 475.AUTHORIZATION IDO# 50-16-6080001B#15026-10000-00453	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72594	10041-20000-25893	705 W 34TH ST	90089	8	120A201   206	5123023024	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/30/2010 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	07/11/2012 12:00:00 AM	PIN	34.02214675	-118.28186522	USC - UNIVERSITY CLUB REMODEL AND ADDITION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72595	13041-20000-28307	1680 N VINE ST	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/10/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	Change to lighting in a historical building.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72596	16041-10000-29370	8800 N COLBATH AVE	91402	6	195B153   689	2639037012	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.23041	-118.44018	PV1 roof mounted solar system installation to a single family home. Installing 2 central inverters rataed at 5.0 and 3.6 KW for a total system size of 8.6 KW. (32) Solar modules.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72597	14041-20001-00357	8901 N DARBY AVE	91325	12	195B125   414	2769003020	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.23212	-118.53406	((EXPEDITE FEES))PV1 CENTRAL INVERTER. SERVICE SIZE 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72598	15041-10000-18871	2101 E PACIFIC COAST HWY NACR BLDG	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Expired	03/05/2018 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALL TWO HIGH RESISTANCE GROUNDING UNITS AND 2- 150 KVA TRANSFORMERS, 1-75 KVA TRANSFORMER.TR226 & TR227 @ NACR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72599	19041-20000-37315	16510 W KNOLLWOOD DR	91344	12	219B137   104	2609016008	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	11/29/2019 12:00:00 AM	ADDRESS	34.29505	-118.49537	PV1. INSTALL 6.12 KW DC SOLAR SYSTEM WITH (24) MODULES AND MICROINVERTER (ENPHASE IQ7-60-2).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72600	15041-10000-19229	2330 W RIPPLE ST	90039	13	150A211   125	5437032002	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Expired	08/17/2017 12:00:00 AM	ADDRESS	34.10672	-118.25294	T-24 ONLY TO AN (E) COMMERCIAL BUILDING. SCOPE OF WORK INCLUDES TWO OFFICES SPACES AND REFRIGERATION ROOM. TOTAL SQ. FT. 5214	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72601	17041-10000-05467	10250 W SANTA MONICA BLVD 2970	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	05/01/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""DISNEY STORE"" Ste. 2970.  Install new panels and its circuits, lights and receptacles. Total effected area: 3,771 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72602	17041-10000-37296	12552 W SHERMAN WAY BLD A	91605	2	183B161    65	2324034019	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.04	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	07/10/2020 12:00:00 AM		Permit Finaled	08/30/2022 12:00:00 AM	ADDRESS	34.20092	-118.40719	FULL PC FOR POWER AND ENERGY FOR A NEW 3-STORY SELF-STORAGE BUILDING(BLDG 1 OF 3). NOTE: THERE ARE THREE BUILDINGS UNDER ONE SET OF PLANS. THIS APPLICATION IS FOR BUILDING A. SCOPE INCLUDES NEW PANELS, NEW LIGHTS AND RECEPTACLES. NEW CONNECTED LOAD > 400A. B#16010-10000-032298	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72603	18041-10000-30603	16616 W SCHOENBORN ST	91343	12	192B137   260	2689010003	MR1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Permit Finaled	10/29/2018 12:00:00 AM	ADDRESS	34.22245	-118.4947	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72604	10041-10000-23521	323 W 8TH ST	90014	14	127-5A209 315	5144014139	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM			PC Approved	11/24/2010 12:00:00 AM	ADDRESS	34.0444	-118.25539	ALTERATIONS IN THE CORRIDORS ON THE 1ST AND BSMNTPLAN CHK IS FO RTITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72605	19041-20000-34249	4730 N TOPEKA DR	91356	3	168B121   319	2176030025	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.15596	-118.54733	PV PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM. SYSTEM SIZE IS 14.4 KW DC, 11.4KW AC. SCOPE OF WORK CONSISTS OF (40) PV MODULES WITH OPTIMIZERS, A 11.4 KW INVERTER, AND (2) BATTERIES TOTALING 27 KWHFEES $0.00 DUE TO CALIFORNIA SENATE BILL 1222 AND AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72606	18041-10000-28266	10716 W LA TUNA CANYON ROAD	91352	7	195B177   108	2544027007	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	34.23372	-118.3642	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72607	10041-20002-08227	15823 W MONTE ST #103	91342	7	225B141  1524	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			05/24/2010 12:00:00 AM	05/24/2010 12:00:00 AM		Permit Finaled	06/28/2010 12:00:00 AM	ADDRESS	34.31094	-118.47588	Supplemental Plan check for revise plans for unit #103. Permit is for (1) extra trip and existing permit plan check T-24 Energy under plan check #10041-10000-08227	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72608	19041-20000-31406	1880 S CENTURY PARK EAST STE 1011-1017, 1020	90067	5	132B161    10	4319001005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.06144	-118.41437	TENANT IMPROVEMENT TO (E) OFFICE IN HIGH-RISE. TOTAL AFFECTED AREA 3,703 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72609	18041-10000-01162	648 N ARDMORE AVE	90004	13	141B193   641	5520002030	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Apartment			01/11/2018 12:00:00 AM			PC Info Complete	06/07/2019 12:00:00 AM	ADDRESS	34.08316	-118.30153	"PC FOR POWER AND ENERGY FOR A New 3-story, 9-unit apartment building over one level. SERVICE SIZE 800A 120/240V 3 PHASE.  SCOPE INCLUDES NEW SERVICE, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 10485.  ""COMPLY WITH DEPARTMENT ORDER effective date 05/13/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.""B# 17010-10000-01930"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72610	18041-10001-42810	755 N LA CIENEGA BLVD	90069	5	141B173   242	4337002075	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.08514	-118.37686	**PLAN CHECK ONLY, PERMIT IS PAID UNDER MASTER APPLICATION**SUPPLEMENTAL CHANGES TO APPROVED SET FOR FIRE ALARM SYSTEM ADDING 10 NEW DEVICES. <<Plan check for a fire alam system located in restaurant with (1) fire alarm panel, (1) power supply, and (62) fire alarm devices.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72611	11041-10000-02288	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/04/2011 12:00:00 AM			PC Approved	02/04/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	T.I. FOR STARBUCKS.  TITLE-24, NEW LIGHTING FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72612	19041-10000-08689	1039 W FLORENCE AVE	90044	8	102B197  1118	6014036019	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	33.97478	-118.29326	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72613	14041-10000-34945	6963 N HAYVENHURST AVE	91406	6	183B137   275	2225002016	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.1975	-118.49257	Remove HID light fixtures and replace with new LED fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72614	16041-10000-03370	3756 N ALTA MESA DR	91604	2	162B161   608	2384009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2016 12:00:00 AM	02/18/2016 12:00:00 AM		Permit Finaled	03/19/2016 12:00:00 AM	ADDRESS	34.13855	-118.41017	Final permit fees are $0 due to senate bill 1222.  PV1 roof mouted installation system to a single family home. (48) Micro Inverters, total rating: 10.32 kw, (48) Modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72615	19041-10000-18035	1106 S GAFFEY ST	90731	15	015B197  1244	7454018027	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	33.73403	-118.2922	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72616	15041-20000-27417	6701 S CENTER DR WEST Suite 720	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	08/31/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	33.97907	-118.39369	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,095 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72617	13041-20000-11388	657 W REDONDO BEACH BLVD 4	90247	15	072B201    91	6120001016	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	ADDRESS	33.89279	-118.28709	existing retail space. new subway. pc for t24 energy only. low connected loads. total area 1132 sq ft. permit to be issued from this application. work done in subway unit 4	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72618	19041-10000-26910	3484 W SAN MARINO ST C	90006	10	132B193  1080	5080008019	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM			PC Approved	07/15/2019 12:00:00 AM	ADDRESS	34.05433	-118.30862	Energy plan check for a juice restaurant T.I located on the 1st floor of a 6-story commercial building. Scope includes new lighting and equipment with a total lighting area of 1167-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72619	14041-10000-35253	21029 W OSBORNE ST	91304	3	195B105    42	2779048008	[Q]MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	34.23316	-118.59177	Title 24 plan check only.  Total area = 7,500 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72620	13041-10001-33075	5649 N IRVINE AVE	91601	2	174B169   659	2339015033	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.17349	-118.38567	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72621	17041-20000-35220	6033 W CENTURY BLVD #950	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/02/2017 12:00:00 AM	10/02/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	33.94572	-118.38954	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT TO OFFICE. 561 SQFT. SUITE 950	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72622	17041-10001-20044												Electrical	Electrical	1 or 2 Family Dwelling			06/14/2017 12:00:00 AM			PC Approved	12/12/2017 12:00:00 AM				void application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72623	15041-10000-07974	9012 N SEPULVEDA BLVD BLDG C	91343	7	195B145   655	2654004053	R3-1, [Q]M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			03/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	09/08/2015 12:00:00 AM	ADDRESS	34.23399	-118.46646	In the lobby of a Bank of America , space is enclosed to form  an ATM room.plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72624	19041-20001-25390	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.27455	-118.56289	Void	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72625	18041-10000-27485	1201 N VINE ST	90038	13	144B185   436	5533006003	C2-1D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM			PC Info Complete	12/14/2018 12:00:00 AM	ADDRESS	34.09285	-118.3268	FULL PC FOR A NEW  CHURCH, OCC. LOAD > 100, WITH BASEMENT GARAGE. SCOPE OF WORK INCLUDES NEW 600AMP SWITCHBOARD WITH NEW LIGHTING AND RECEPTACLE LOAD. TOTAL SQ. FT. 11074.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72626	10041-10000-25636	3651 S WATT WAY 7TH FL	90089	9	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			PC Approved	01/05/2011 12:00:00 AM	ADDRESS	34.02013	-118.28812	remodel laboratory rooms 720 & 721 at the VHE LAB.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72627	19041-10000-20648	4326 S COOLIDGE AVE	90066	11	111B161   472	4217008019	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	10/31/2019 12:00:00 AM	ADDRESS	34.00013	-118.41592	PV1. New LADWP Community Solar Program: 3.00KWdc / 2.64 kW AC - 11 solar modules and 11 enphase IQ7-60-2 micro-inverters. 1 circuit. Solar system is interconnected at existing service point of the single family home.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72628	14041-20000-24874	7006 S HOOVER ST	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 2KW INTERCONNECTED WITH House Panel.ENPHASE M250 MICROINVERTER.zoning clearance under this application shall be applicable for all solar installations under this building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72629	12041-10000-14039	11444 W OLYMPIC BLVD 5TH FLOOR	90064	11	123B153   126	4260017022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/18/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	09/05/2012 12:00:00 AM	ADDRESS	34.03654	-118.44363	"INTERIOR TENANT IMPROVEMENT OF (E)OFFICE.   Change to lighting and receptacles.  PLAN CHECK ONLY for T-24, with Emergency lighting.  Permit fees are under ""Inspection""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72630	16041-20000-01806	6415 W RIGGS PL	90045	11	102B165    61	4110013030	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	33.97882	-118.39928	PV1. Install roof mounted PV system sized 8 kW. Interconnected with main servive panel.(32) Sunmodule Plus SW 286 Modules(32) Enphase M250 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72631	12041-20001-28906	2336 S CRENSHAW BLVD	90018	10	123B185   263	5060004003	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.01	Electrical	Electrical	Apartment			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Closed	07/29/2014 12:00:00 AM	ADDRESS	34.0359	-118.33304	Plan check for removing 1 car charger from house pannel and add 4 more car chargers to 202D, 203D, 302D and 303D units(((New 10-unit  apartment complex in a METHANE ZONE.  3-stories.  Full Plan Check required.  <<<Additional plan check fees required, Applicant has a pre-printed check>>>>)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72632	19041-10000-52491	3200 S MOTOR AVE	90064	5	123B161   610	4316033002	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	Commercial			12/19/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.03145	-118.41085	"REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS.INDOOR ""ADMIN. BLDG 1ST FL"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72633	16041-20000-36370	18810 W VANOWEN ST	91335	3	180B121    39	2126035028	RA-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.1937	-118.54306	remove existing hid light fixtures and replace with new led outdoors.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72634	14041-20001-00751	17751 W STRATHERN ST	91335	12	189B129   438	2101003007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/19/2014 12:00:00 AM	ADDRESS	34.21577	-118.52052	((Expedite Fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72635	18041-20000-22685	5924 N NORA LYNN DR	91367	3	177B085   539	2032026011	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	34.17802	-118.66512	PV1.  Install 14.85 kW DC roof mounted grid tied PV system.  (45) modules with (2) 7.6 kW string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72636	14041-10005-07239	11985 W BLUFF CREEK DR BLDG 3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Info Complete	08/26/2015 12:00:00 AM	ADDRESS	33.98221	-118.40251	((((8/26/2015))))CHANGES TO AN APPROVED SET OF PLANS.  ADDING 3 SENSORS PER PAGE MG 2.00.METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35606.BLDG PERMIT: 13010-10000-04244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72637	18041-10000-39706	1515 N VERMONT AVE #8306-& 8307	90027	13	147B197   612	5543012022	C2-CSA1	Central	Hollywood	East Hollywood, Los Feliz	YES	1912.01	Electrical	Electrical	Commercial			10/17/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.09867	-118.29207	PLAN CHECK FOR POWER AND ENERGY.  TI TO EXISITING PHARMACY WORKROOM #8306 AND CONVERT MEDICAL OFFICE #8307 INTO VESTIBULE FOR PHARMACY IN THE ONCOLOGY DEPARTMENT OF A MEDICAL BULDING. INSTALL (1) NEW PANELBOARD AND ALL OTHER POWER WERE FED FROM EXISTING DISTRIBUTION BOARD.(BULDING PERMIT: 18016-10000-01115)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72638	10041-20000-15529	11075 W SANTA MONICA BLVD Suite 350	90025	5	129B153   757	4324033022	[Q]C2-1VL-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			08/10/2010 12:00:00 AM	08/10/2010 12:00:00 AM		Permit Finaled	10/21/2010 12:00:00 AM	ADDRESS	34.04799	-118.44397	lighing and power in existing office area. P/C is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72639	13041-10000-27138	5127 E SAN RAFAEL AVE	90042	1	153A225   268	5469004029	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.11338	-118.20471	PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 4.5 kW. TRANSFORMERLESS INVERTER. 2 STORY.(23) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-5000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72640	14041-20001-13756	3006 N ARROWHEAD DR	90068	4	156B185   112	5577035049	RE15-1-H	Central	Hollywood	Hollywood United	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM			PC Approved	06/02/2014 12:00:00 AM	ADDRESS	34.12372	-118.3284	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12.9KW INTERCONNECTED WITH MAIN PANEL.(53) MODULES ET SOLAR ET-P660245BB(2) TRANSFORMERLESS POWER-ONE  PVI-6000-OUTD-US-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72641	18041-10000-11981	8550 N BALBOA BLVD 290	91325	12	192B133    31	2689019013	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/03/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.22649	-118.5024	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR OFFICE.  2052 SQFT. SUITE 290 BUILDING PERMIT # 18016-10000-03764	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72642	10041-10000-18618	7801 W MELROSE AVE # 1A	90046	5	141B177   529	5527010013	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			09/20/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.08391	-118.35962	T-24 lighting plan check for remodeled space.  Space 1A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72643	13041-10002-21428	1245 W WILSHIRE BLVD 1ST FLOOR	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	10/28/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	Plan check for revisions under delta 10. changes include the addition of a circuit and revisions of notes. ***Plan check Delta 5 revision. Minor changes to circuitry. No permit to be issues. Plan check only. ***RADIATION ONCOLOGY ON FIRST FLOOR OF HIGH RISE MEDICAL OFFICE BUILDING. PLAN CHECK POWER & ENERGY INCLUDING OSHPD 3 REQUIREMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72644	19041-20002-00997	20851-20853 N SHERMAN WAY	91306	3	183B109    62	2113013038	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1340.02	Electrical	Electrical	Commercial			07/24/2019 12:00:00 AM			PC Approved	07/24/2019 12:00:00 AM	PIN	34.20136408	-118.5880133	07-24-2019 Changes to an approved set of plan, changes include update fault current calculation with motor contribution, all equipment is series rated for 200KAIC. All changes has been clouded.  Plan check only. No new equipment being added, permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72645	18041-10000-47948	1237 W 71ST ST	90044	8	102B197   945	6014031024	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	33.97551	-118.29714	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 9 MODULES (JKM290M-60) , 9 MICROINVERTERS (ENPHASE IQ7-60-2-US). SYSTEM SIZE IS 2.61 KWdc and 2.31 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72646	15041-20000-36704	11505 N VIMY ROAD	91344	12	213B129   228	2601037045	A1-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.28018	-118.52193	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.4KWac. (36) MODULES-SUNPOWER SPR-E20-327(36) OPTIMIZERS-SOLAREDGE P400(1) CENTRAL INVERTER-SOLAREDGE SE11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72647	17041-20001-10040	13509 W VENTURA BLVD	91423	4	165B157   689	2360008040	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM	05/03/2017 12:00:00 AM		Issued	05/03/2017 12:00:00 AM	ADDRESS	34.14756	-118.42742	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from beauty parlor/office to massage parlor and a tenant improvement. Total lighting area = 2,096 sq. ft.Note: Building permit has been pulled under 16016-20000-12059	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72648	15041-20002-02921	11813 W VALERIO ST	91605	2	186B169   659	2317017010	RD2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Apartment			03/03/2015 12:00:00 AM			PC Approved	03/03/2015 12:00:00 AM	ADDRESS	34.20495	-118.39087	PC FOR CHANGE IN POI. NOW PV SYSTEM WILL INTERCONNECT TO AN UPGRADE TENANT PANEL. TENANT PANEL COMES FROM AN EXISTING 400A SERVICE. SERVICE TO APARTMENT DOES NOT HAVE MAIN BREAKER PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72649	17041-20000-18988	301 W WORLD WAY NORT suite 337	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	08/22/2017 12:00:00 AM	PIN	33.94684048	-118.40128468	plan check for t-24 energy sigh lighting for stabucks in LAX.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72650	18041-10000-18415	450 S WESTERN AVE #313	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.06562	-118.30887	CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT; FIRST TI WITHIN NEW  SHELL COMMERCIAL BUILDING	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72651	16041-10000-29279	11114 W MAGNOLIA BLVD	91601	2	171B173   621	2353005028	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM	09/30/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.1647	-118.37303	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO TAKE OUT RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 789 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72652	14041-10001-12437	127 S LA BREA AVE	90036	5	138B181   989	5513019011	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			09/08/2014 12:00:00 AM			PC Approved	09/08/2014 12:00:00 AM	ADDRESS	34.07273	-118.34423	[[9/8/14  CHANGES TO APPROVED SET OF PLANS. PLANCHECK ONLY. DELTA 2 CHANGES ONLY. CHANGES TO LIGHTING ONLY]]]TI TO EXISTING RESTAURANT. PLAN CHECK IS FOR POWER AND ENERGY, OCCUPANT LOAD EXCEEDS 100. EXISTING SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72653	16041-10000-14758	12615 W KESWICK ST	91605	2	186B161    77	2305023011	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Finaled	09/13/2016 12:00:00 AM	ADDRESS	34.20989	-118.40813	PV1 roof mounted solar system to a single family home. Total system size is 7.6KWac. (2) Inverters-Sunnyboy 3800TL-US   (25) Solar modules. (1) load center 100 A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72654	14041-10000-16988	932 E 61ST ST	90001	9	105B209   120	6007008006	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			06/24/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Issued	06/26/2014 12:00:00 AM	ADDRESS	33.98427	-118.25838	plan check for power only. SERVICE UPGRADE ONLY per supervisor (only 'MS'). Changes on plan include bollards, 2/0 GEC, and 34kaic from utility.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72655	16041-20000-03838	10020 N ETON AVE	91311	12	204B105   716	2747013052	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.25265	-118.59497	Plan check for PV roof mounted system. System size: 8.4kW with 30 modules and 30 microinverters. Standard plan is being use. Center feed service and load calculation is provided.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72656	18041-20001-21223	2222 N MARAVILLA DR	90068	4	150B181   103	5549013025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	12/28/2018 12:00:00 AM	ADDRESS	34.11034	-118.34337	10-31-2018 Changes to an approved set of plan, changes include addition of 2 Energy storage system Tesla PowerWall 2.0 into PV System. Total Energy Storage system size: 27KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72657	18041-10000-10948	1800 S WESTERN AVE	90006	10	126B193   607	5074015050	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			PC Approved	11/21/2018 12:00:00 AM	ADDRESS	34.04161	-118.30873	NEW MCDONALD RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72658	19041-20000-12273	8119 S GRIMSBY AVE	90045	11	099B169  1064	4105029008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	11/21/2019 12:00:00 AM	ADDRESS	33.96473	-118.37953	Plan check for PV and enegy storage system, PV system size: 7.6KW with 19 PV modules and 1 battery  LG Chem 9.8kWh, 100A panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72659	12041-10000-20540	19800 S VERMONT AVE	90502	15	057B197    54	7351033039	[Q]C4-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM	09/26/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	33.85122	-118.29031	TI in the first floor of an existing hotel (lobby areas). EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72660	13041-10000-33095	23016 W VANOWEN ST	91307	12	180B097    19	2038019002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Expired	01/27/2016 12:00:00 AM	ADDRESS	34.19354	-118.62838	PV1, Install 6.5 kW DC roof-mounted photovoltaic system to interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE6000A-US., power optimizer,  26 modules TRINA SOLAR TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72661	13041-20000-20172	11617 W PICTURESQUE DR	91604	2	162B169   747	2369035027	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	34.13905	-118.38483	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE: 8.27 KW. 37 MODULES AND 2 INVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72662	18041-20001-29136	9754 N YOLANDA AVE	91324	12	201B121   313	2763029031	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM			PC Approved	11/29/2018 12:00:00 AM	ADDRESS	34.24821	-118.54031	Revision to approved plans.  Change of module type and quantity (36 modules total).  (((PV1.  Install 11.895 kW roof mounted grid tied PV system.  (39) modules with (2) 5.2 kW rated string inverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72663	18041-10002-09694	2223 W BERKELEY AVE	90026	13	142-5A207 233	5423010013	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM			PC Approved	07/16/2018 12:00:00 AM	ADDRESS	34.08443	-118.26173	PC FOR CHANGES TO APPROVED SET. CHANGES INCLUDE RELOCATING MODULES ON THE ROOF-LAYOUT, REMOVAL OF 2 MODULES. ALSO CHANGES ON THE SINGLE LINE DIAGRAM.NOTE: PERMIT IS PAID UNDER THE MASTER APPLICATION 18041-10000-09694	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72664	12041-10000-27425	6621 W 83RD ST	90045	11	099B165  1119	4108002008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	11/30/2012 12:00:00 AM	ADDRESS	33.96366	-118.40524	PV1 3.43KW ROOF-MOUNT ENPHASE MICROINVERTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72665	19041-10000-00907	1515 W 190TH ST STE-250	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	Design build: Energy plan check for an interior partition office shell with 25,704 SQ FT. TI OF OFFICE SUITE SHALL BE UNDER SEPERATE PERMIT.BLD: 18016-10000-32383	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72666	17041-10000-15615	3813 W RONDA VISTA PL	90027	4	150B201  1138	5433009035	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Closed	03/16/2020 12:00:00 AM	ADDRESS	34.10477	-118.27596	Installation of four new Tesla AC Powerwall 5.8 kVA battery storage systems.  Interconnect to existing rooftop PV system via new 200 amp load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72667	15041-10000-17154	5631 S MESMER AVE	90230	11	105B165   320	4220014031	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM			PC Info Complete	06/10/2015 12:00:00 AM	ADDRESS	33.9854	-118.40058	TI-24 TO AN (E) COMMERCIAL BUILDING, ADDING NEW LIGHTING. PC FOR ENRGY ONLY, TOTAL SQ FT. 7122. permit issued under application # 16041-30000-00927	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72668	15041-10001-14585	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/28/2015 12:00:00 AM			PC Approved	12/28/2015 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delta30 changes to permitted set of plans- updated Lighting Fixture Schedule; panel schedules revised to show new loads added and other loads removeALL CHANGES ARE CLOUDE AND IDENTIFIED AS DELTA 30 CHANGES((((((((((TERMINAL 7 TICKETING, SSCP AND BAG CLAM. PC FOR POWER AND ENERGY. PC FEES ESTIMATED PER APPLICANTS APPLICATION ADDITIONAL FEES MAY BE REQUIRED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72669	12041-10000-06970	12301 W PICO BLVD	90064	11, 5	126B157   893	4255028005	[Q]C2-1D, [Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles, Westside		2676.00, 2678.00	Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM	07/12/2012 12:00:00 AM		Permit Finaled	02/12/2014 12:00:00 AM	ADDRESS	34.02858	-118.45242	New 95 unit condominium project with Live/Work space on the 1st floor.  5-story building.  2000A service size.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72670	09041-10001-02075	4658 W MELROSE AVE	90004	13	141B193   584	5521007001	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	Commercial			01/19/2011 12:00:00 AM			PC Approved	01/19/2011 12:00:00 AM	ADDRESS	34.08333	-118.30203	Delta 4 revisions to permitted set of plans-use of L MC FEEDERS TO THE PANELBOARDS; CHANGES TO LUMINAIRES FOR THE EXTERIOR CANOPYPlan check power and energy (indoor/outdoor lighting) for commercial retail building.  New 1200A service, board, equipments, and circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72671	14041-10000-24368	3440 S MOTOR AVE	90034	5	120B161   319	4314016031	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			09/05/2014 12:00:00 AM			PC Approved	09/05/2014 12:00:00 AM	ADDRESS	34.02715	-118.40887	Title 24 plan check only.  Total area = 1,944 sq. ft.Lighting and recepticles to existing commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72672	18041-10000-41493	450 N BELLAGIO TER	90049	5	141B145   465	4368020023	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.07873	-118.46252	ROOFTOP SOLAR SYSTEM RESIDENTIAL WITH 27 PANELS, 7.965 KWDC, 1 INVERTER, 1 NEW PRODUCTION METER, 1 125AMP SUB PANEL, 1 BATTERY BACKUP	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72673	18041-20000-41537	10111 N VANALDEN AVE	91324	12	204B121   371	2729025006	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Issued	11/13/2018 12:00:00 AM	ADDRESS	34.25411	-118.54935	Plan check for a PV1 roof-mounted PV system. System size is 9.9 kWdc/8.769 kWac-CEC and consists of (1) 7.6 kWac-rated inverter and (33) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72674	11041-10000-00446	540 S NORMANDIE AVE	90020	4	135B197   947	5502018002	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00	Electrical	Electrical	Commercial			01/10/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	10/05/2012 12:00:00 AM	ADDRESS	34.06411	-118.30015	New Methane gas control system.  Electrical Plan Check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72675	19041-10000-05299	970 W 190TH ST #550	90502	15	060B197  1714	7351031029	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	33.85812	-118.29302	RELOCATING EXISTING FIRE ALARM DEVICES IN SUITE #550,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72676	18041-20000-26595	11933 W WILSHIRE BLVD	90025	11	129B145   944	4265014041	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			07/17/2018 12:00:00 AM	08/30/2018 12:00:00 AM		Permit Finaled	06/26/2019 12:00:00 AM	ADDRESS	34.04639	-118.46493	ti and 600 amp service upgrade to an existing two story commercial building.  adding new lighting new controls to new panels.  plan check for power and energy.Note: Building permit has been issued under 17014-30000-03995	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72677	12041-10000-19542	747 E 10TH ST	90021	14	124-5A211 351	5132001***		Central				2260.00	Electrical	Electrical	Commercial			08/20/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	10/19/2012 12:00:00 AM	ADDRESS	34.03509	-118.25044	FIRST TENANT ( OPEN BANK) IN NEW COMMERCIAL SPACE- UNITS 3-10 AND 3-11PLAN CHK IS FOR TITLE 24 AND POWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72678	19041-10000-53538	7357 N WHITE OAK AVE	91335	3	186B129   913	2121015022	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.20457	-118.51879	New PV1 roof mounted installation with a system size of 4.64KW DC/4.24KW AC, 16 modules (REC290TP2), 16 power optimizers (P320), 1 central inverter (SE3800H-US), and existing main service rated for 100A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72679	17041-10000-36842	4575 E HUNTINGTON DR SOUTH	90032	14	142-5A231  88	5213013904	PF-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	34.08529	-118.18677	REPLACE EXISTING FIXURE WITH NEW LED FIXURE - TITLE 24 ONLY TOTAL AFFECTED AREA 9450 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72680	19041-20000-49775	6932 N GROSS AVE	91307	12	183B093   567	2028013004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.19499	-118.64003	PV1.  Installation of (N) 5.280 kW DC addition to (E) 9.840 kW DC PV system.  Total system size is 15.120 kW DC.  (16) new modules with 11.4 kW rated inverter.  Reconnect (32) existing modules to (N) inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72681	15041-10000-05307	6911 N VALJEAN AVE	91406	6	183B137   359	2224022021	M1-1, P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.19593	-118.48602	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 8560 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72682	10041-10000-01626	2000 S CENTRAL AVE	90011	9	120A211   451	5119001***	R2-1, [Q]C2-1, [Q]R4-1	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM			PC Approved	02/10/2010 12:00:00 AM	ADDRESS	34.02249	-118.25156	Chnages to the shell of the project: redistribute panels and chenge equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72683	19041-20000-47682	20447 W VIA CELLINI	91326	12	219B109   264	2701055014	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.29479	-118.58067	PV1. INSTALL 16.08 KW DC PV SYSTEM WITH (48) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72684	18041-10000-07755	21600 W CEZANNE PL	91364	3	165A105   163	2173003010	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	Yes	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.14621	-118.60284	Plan check for a 11.73KW DC PV1, roofmounted system. Scope includes (35) modules, (35) Optimizers and (2) central inverters interconnecting through the main service panel.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72685	13041-10002-16329	501 WORLD WAY	90045	11	090B165   128	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	33.94297	-118.40516	03/28/17Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding battery packs for lights in the elevator lobby. Note: permit is paid under PCIS#13041-10000-16329	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72686	10041-10000-21655	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			12/08/2010 12:00:00 AM	04/06/2011 12:00:00 AM		Permit Finaled	01/30/2012 12:00:00 AM	ADDRESS	34.01118	-118.33649	Misc. exterior common area, mall common area adn food court renovation include new tile floors, new paint, new children's play area, re-design food court, new food commissary, new performance stage, new food kiosks, new restrooms, upgrade building entrances, new mall management office. EPC is for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72687	18041-20000-11324	700 S LOS ANGELES ST	90014	14	127-5A211 193	5145002002	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	01/25/2019 12:00:00 AM		Issued	01/25/2019 12:00:00 AM	ADDRESS	34.04304	-118.25042	"Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from ""M"" to ""A-2"" occupancy/tenant improvement, multiple tenates in this occupancy. Total lighting area = 13,555.1 sq. ft.Note: Building application has been generated under 18016-10000-09405."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72688	15041-10000-23698	20750 W SHERMAN WAY	91306	3	183B109    80	2137020037	(T)RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	Apartment			07/24/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.20086	-118.5852	REGULAR PLAN CHECK PROVIDE NEW FIRE ALARM SYSTEM  FOR A 3 STORY APARTMENT BLDG.(1) FIRE ALARM SYSTEM(3) CONTROL PANELS(2) COMMUNICATION PANELS(191) FIRE ALARM DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72689	19041-10000-17668	2000 W MIRAMAR ST 1-22	90057	13	135A205   224	5154020030	R4-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Apartment			05/10/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	03/25/2021 12:00:00 AM	ADDRESS	34.06323	-118.27067	$0 fee per AB1414. PV2. NEW ROOF MOUNTED SOLAR SYSTEM CONSIST OF 165 MODULES (TALLESUN 365W), OPTIMIZERS (SE P800) AND 2 CENTRAL INVERTERS (SE 43.2K AND SE9KUS) SYSTEM SIZE IS  60.2KWdc AND 52.2KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72690	14041-20001-12843	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			PC Info Complete	06/26/2015 12:00:00 AM	ADDRESS	34.08363	-118.32191	[[6/26/15 CHANGES TO APPROVED SET. INSTALLATION OF A 250 AMP PANEL FOR FUTUTE HVAC LOADS. REMOVING APPROVED DOUBLE FEED TO EXISITING SINGLE FEED.]]]]]]pc for power. 2 new 4160v feeders. serving 2 new service substations. distribution equipment. pc for energy for new lighting in electrical room.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72691	11041-10000-07792	401 W CENTER WAY	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	2780.00	Electrical	Electrical	Commercial			04/19/2011 12:00:00 AM	05/10/2011 12:00:00 AM		Permit Closed	02/03/2015 12:00:00 AM	PIN	33.93790872	-118.42837934	TEMPORARY POWER AT LAX FOR CONSTRUCTION TRAILERS. 5000A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72692	19041-20000-07527	431 N PASEO MIRAMAR	90272	11	126B117    20	4416001026	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM	04/02/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.04528	-118.55525	PV1.  Install 31.35 kW DC / 22.8 kW AC and consists of (95) modules, (95) micro-inverters, and (1) load center.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72693	10041-10000-15331	101 N BOYLE AVE 1-52	90033	14	129A221   187	5174024020	R3-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.30	Electrical	Electrical	Commercial			08/13/2010 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.04738	-118.22008	New 51 unit apartment building in a split 3 & 4 story building.  A variance to separate the electrical and fire alarm plan check was submitted on November 17, 2010.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72694	16041-10000-39559	6353 N VICLAND PL	91606	2	180B173   963	2336020017	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2016 12:00:00 AM	11/08/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.1859	-118.37205	PV, INSTALL 4.905 ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(15) AC INVERTERS: SPR-E20-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72695	17041-10000-12766	4700 W PICO BLVD SUITE J	90019	10	129B185  1011	5083033019	[Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	09/16/2017 12:00:00 AM	ADDRESS	34.04846	-118.33732	Title 24 plan check.  T.I. to existing retail store.  New lighting, receptacles, and HVAC.  Total area = 2,341 sq. ft.     Building permit #17016-10000-09943	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72696	19041-10000-06415	11800 W KAGEL CANYON ST 1-49	91342	7	210B169   161	2530008901	(T)RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1041.08	Electrical	Electrical	Commercial			02/22/2019 12:00:00 AM	05/28/2020 12:00:00 AM		Permit Finaled	11/21/2023 12:00:00 AM	ADDRESS	34.27327	-118.39034	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES A NEW 1600A SERVICE/DISTRIBUTION BOARD, NEW UNIT PANELBOARDS, CIRCUIT AND LIGHTS , 120/208V, 3PH, 4W. TOTAL AFFECTED AREA IS 36,620 SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72697	16041-10000-11008	711 W COLLEGE ST	90012	1	135A213    31	5414001009	C2-2D-O	Central	Central City North	Historic Cultural	YES	2071.03	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Info Complete	03/30/2016 12:00:00 AM	ADDRESS	34.06555	-118.24154	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR OFFICE SPACE. TOTAL AFFECTED AREA IS 1721 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72698	17041-20000-14123	7767 N JAMIESON AVE	91335	12	189B129  1064	2120007013	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.21184	-118.52157	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13.325 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72699	17041-10000-05207	6540 W HOLLYWOOD BLVD	90028	13	148-5A187 184	5547016005	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Info Complete	06/05/2017 12:00:00 AM	ADDRESS	34.10142	-118.33231	PC for power only. Replace existing service with New 800 A  service and switchboard. All panels are exisitng. No new connected load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72700	14041-20000-06177	4423 N COLDWATER CANYON AVE	91604	2	165B161   226	2362013023	R4-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Apartment			03/06/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.15104	-118.41397	PV2 ROOFMOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5.0KWAC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72701	13041-10001-14861	1644 S BENTLEY AVE 1-9	90025	5	129B153   667	4324032009	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			01/16/2015 12:00:00 AM			Reviewed by Supervisor	01/27/2015 12:00:00 AM	ADDRESS	34.04864	-118.44372	(1/16/15) In each apartment unit feeders changed and load calculation changed.Each apartment unit incorporates an electric range.(((New five story 9-unit condo.  Power and energy full plan check.  Methane zone.  Modification to separate fire alarm plans filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72702	14041-10000-10850	321 N LARCHMONT BLVD 1010	90004	4	138B189   330	5523020038	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.07682	-118.32384	PLAN CHECK FOR POWER AND ENERGY OF EXISTING DENTIST TI.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72703	17041-10000-39839	1611 W 190TH ST	90248	15	060B193   387	7351001024	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	33.85851	-118.30732	Replace Outdoor HID Fixtures with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72704	15041-20001-01245	2024 N CUMMINGS LANE	90027	4	151-5A195 180	5589009033	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM			PC Approved	01/27/2015 12:00:00 AM	ADDRESS	34.10793	-118.30124	EXPEDITE PER CUSTOER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 12KW INTERCONNECTED WITH MSP.(36) SUNPOWER SPR-E20 MODULES(2) SMA SB6000TL INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72705	13041-10000-03942	735 S FIGUEROA ST #118	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/14/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	07/23/2013 12:00:00 AM	ADDRESS	34.04878	-118.26079	FIRST TIME TENANT IN COMMERCIAL SPACE INEXISTING  FOOD COURT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72706	19041-20000-10728	20150 W RINALDI ST	91326	12	210B113   287	2701099014		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	04/04/2022 12:00:00 AM		Issued	04/04/2022 12:00:00 AM	ADDRESS	34.2747	-118.57329	1600A 480Y/277V 3ph-4w service, distribution, power, and lighting for new hotel.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72707	17041-10000-37063	523 W 6TH ST # 1128	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3812 SQ. FT.  B#17016-10000-25086	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72708	18041-20001-01030	9055 N RESEDA BLVD	91324	12	198B125   272	2770004005	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM			PC Approved	12/06/2018 12:00:00 AM	ADDRESS	34.23509	-118.53635	12/06/2018 Changes to an approved set of plans. All changes have been clouded. Changes include the addition of an AC disconnect switch per LADWP request and the relocation of the performance meter.Note: No changes to roof layout. Master plan set has LAFD approval.*****Previous Work Description*****Plan check for a PV2 roof-mounted PV system. System size is 25 kWac and consists of (2) inverters, (1) load center, and (90) modules.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72709	15041-20000-03459	14915 W ROSCOE BLVD	91402	6	192B149   371	2653023013	R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.06	Electrical	Electrical	Apartment			02/05/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	10/26/2016 12:00:00 AM	ADDRESS	34.22163	-118.4582	NEW 22 UNIT APARTMENT. PC FOR POWR AND ENERGY.FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72710	17041-20001-30882	9999 N WORNOM AVE	91040	7	204B177   216	2543027003	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM			PC Approved	09/05/2017 12:00:00 AM	ADDRESS	34.25223	-118.35283	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.17.6kW ungrounded system. (60) 330W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72711	15041-10000-21014	8478 N DELCO AVE	91306	3	192B109   274	2781024018	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2015 12:00:00 AM			Reviewed by Supervisor	08/14/2015 12:00:00 AM	ADDRESS	34.22415	-118.57844	PV1, INSTALL 5.23 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(16) MODULES:SUNPOWER SPR327NE-WHT(1) INVETER: POWER ONE PVI3.8-1-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72712	18041-10000-28675	1206 N TIGERTAIL ROAD	90049	11	141B137   214	4493023019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	11/01/2018 12:00:00 AM	ADDRESS	34.07984	-118.48719	Plan check for a PV1 7.6KW AC roof mounted system. Scope includes (1) 7.6kw inverter, (21) modules and optimizers.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72713	19041-10000-05339	4957 W MELROSE AVE	90029	13	141B193   524	5535018901	PF-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.08362	-118.30804	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72714	13041-20000-26150	11455 N LAUREL CANYON BLVD	91340	7	213B149   511	2613027020	(T)(Q)C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1095.00	Electrical	Electrical	Commercial			09/24/2013 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.27805	-118.4529	New hamburger restaurant, with 1000 amp service.  Not in a Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72715	14041-20002-07530	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	33.97749	-118.41246	[2/24/2015 CHANGES TO APPROVED SET OF PLANS.  Fault current calculations are updated to reflect field conditions (feeder lengths increased resulting in lower Isc).  Breakers with reduced AIC ratings used.  Plan check at request of inspector.]][1/16/15 CHANGES TO APPROVED SET OF PLANS. PLANCHECK PER INSPECTOR REQUEST. VOLTAGE DROPS AND CHANGES TO ELEVATOR AND FREIGHT ELECATORCHANGES ARE CLOUDED.]]LARGE TI FOR EXISTING OFFICE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72716	11041-10000-15695	200 N GRAND AVE	90012	9	132A213     1	5161004909	PF-2D, [Q]OS-2D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	12/07/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.05685	-118.24763	New fire alarm for a 3 story (including garage) school.  Pan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72717	17041-10003-01258	8151 N VENTURA CANYON AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM			PC Approved	03/22/2018 12:00:00 AM	ADDRESS	34.21934	-118.42889	PC FOR CHANGE PER APPLICANT REQUEST FOR DELTA 9.SCOPE INCLUDE NOTES REVISIONS, CONDUCTOR LABLES CHANGES AND ADDING NEW L.VOLTAGE COMM. ENCLOSURE. THIS IS PLAN CHECK ONLY. CHNGING Plan check for power only, new Fuel Cell system rated at 1.6 MW. Fuel cell system is rated at 480 V conncected to 4.16KV (Medium Voltage) distribuition system OSHPD.  Installation on Keiser building connected exterior to OSHPD  4160 V medium voltage service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72718	11041-10000-26808	6161 N SEPULVEDA BLVD	91411	6	177B145   392	2242001011	M1-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	05/18/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.1821	-118.46652	PLAN CHECK POWER AND ENERGY FOR NEW LA FITNESS HEALTH CLUB BUILDING WITH 2000A SERVICE. SITE IN METHANE BUFFER ZONE, NO METHANE DETECTED ACCORDING TO METHANE REPORT. MODIFICATION TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72719	15041-10000-13025	13854 W COMMUNITY ST	91402	6	192B153   707	2637028014	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Permit Finaled	08/11/2015 12:00:00 AM	ADDRESS	34.2225	-118.435	PV1 ROOF MOUNTED SYSTEM, 21 MODULES 2 INVERTERS. TOTAL 6KW. SUBMIT PER APPLICANT'S REQUEST.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72720	19041-10000-32095	19241 W DEARBORN ST	91324	12	198B117   179	2762036004	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Issued	10/03/2019 12:00:00 AM	ADDRESS	34.23746	-118.55188	INSTALL A NEW TESLA 13.45KWH POWER WALL SYSTEM TO AN EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72721	19041-10000-26994	1520 N AMALFI DR	90272	11	132B133   153	4425021020	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM			Verifications in Progress	08/19/2019 12:00:00 AM	ADDRESS	34.0581	-118.50418	[E-PLAN] Installation of a new battery storage system (Sonnen Battery & inverter combo) with an existing PV system. Scope includes 400A exusting service, Manual transfer switch, and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72722	18041-10000-15484	3401 S CENTRAL AVE	90011	9	115-5A209  25	5114015901	PF-1	South Los Angeles	Southeast Los Angeles	South Central		2283.10	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.01267	-118.25668	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72723	16041-10000-34072	21061 W SUPERIOR ST	91311	12	201B105   174	2746003004	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.24646	-118.59248	Permit fee are $0 due to senate bill 1222.New PV2 rooftop solar installation, 72 kW AC.   (247)  CS modules,    (3) STP 24000TL inverters 480/277V 3ph.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72724	16041-20000-11205	6225 W CENTURY BLVD	90045	11	090B165     5	4124026005	C2-2, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/31/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	33.9457	-118.39456	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the 1st floor lobby bar and restaurant and 3rd floor regency lounge. Total lighting area = 2,507 sq. ft.Note: Building application has been generated under 16016-10000-05346	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72725	13041-10002-21438	1245 W WILSHIRE BLVD 2ND FLOOR	90017	1	132A207   288	5143017037	CW	Central	Westlake	Downtown Los Angeles	YES	2091.02	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM			PC Approved	08/30/2017 12:00:00 AM	ADDRESS	34.05373	-118.26606	CHANGES TO APPROVED SET OF PLANS. REVISED CIRCUIT FOR RELAY DEVICE AS NOTED ON PANEL SCHEDULES. CHANGE NOTED DELTA RFI-364 ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72726	17041-10000-30902	1833 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Issued	08/29/2017 12:00:00 AM	ADDRESS	34.04342	-118.37677	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURE T-24.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72727	13041-10000-19495	1251 S EDRIS DR 1-5	90035	5	132A167   195	4330024021	RD1.5-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			07/23/2013 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.05575	-118.39818	pc for power and energy. NEW 5 UNIT APT 4 STORIES OVER SUB TER. GARAGE. METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72728	11041-20000-07518	1872 S SEPULVEDA BLVD C2	90025	5	126B153    95	4323021015	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/14/2011 12:00:00 AM	04/14/2011 12:00:00 AM		Permit Finaled	05/26/2011 12:00:00 AM	ADDRESS	34.04498	-118.44183	TI, denta office.  adding lights and some circuits.  Plan check is for T24 only.  Location C2	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72729	16041-20001-06706	4151 W PROSPECT AVE BLDG G	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.10191	-118.28217	07-14-2016 Changes to an approved set of plan. Changes include update feeders size to match existing feeder, and down size circuit breaker on SUBSTATION-8 AND-9 clouded delta1{{{{Refurbishing of busing and adding new circuit breakers to (E) switchgear.  Plan check for power.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72730	17041-10000-06612	3201 S HOOVER ST Ste 1850	90007	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	07/19/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	PC for power and energy for restuarant. This is a first time tenant. Scope of work includes three new panels supplied from existing 1600A 120/208 V switchboard and a total area of 1782 sqft . Building permit under 17016-10000-04703.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72731	13041-10001-18721	4953 N DEL MORENO DR	91364	3	168B113    28	2166044011	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	09/12/2013 12:00:00 AM	ADDRESS	34.16053	-118.5763	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN. SYSTEM SIZE IS 7.350 KW DC. PERMIT PULLED UNDER APPLICATION NUMBER 13041-20000-17814. 30 MODULES IN 3 STRINGS [INVERTER: FRONIUS # IG PLUS V 7.5 |||| MODULES: TRINA SOLAR # TSM-245PC05/PA05.18]((((((((((((((((((    ADDITION OF COMBINER BOX TO 10000 SET.))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72732	19041-10000-30687	888 S FIGUEROA ST # 360	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	09/06/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.0465	-118.26225	TI IN OFFICESPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72733	16041-20000-21189	10353 W DIAMOND ST LOT 5	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72734	18041-20000-07711	1245 N NEW HAMPSHIRE AVE 1-9	90029	13	144B197    77	5540015009	R3-1XL	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Apartment			03/02/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	04/13/2022 12:00:00 AM	ADDRESS	34.0947	-118.29345	New 3-story 9-unit apartment building.  800A 240/120V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72735	18041-10000-40596	431 W 7TH ST	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/23/2018 12:00:00 AM			PC Approved	10/25/2018 12:00:00 AM	ADDRESS	34.04654	-118.25516	TI IN AN EXISTING OFFICE BUILDING ON THE 1ST AND 2ND FLOORS of a High Rise Building in Suite #'s 110, 111 & 112. T-24 ENERGY ONLY.Building Permit: 18016-10000-13469	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72736	16041-20000-05911	758 E 21ST ST	90011	9	121-5A209 338	5131012006	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	04/25/2016 12:00:00 AM	ADDRESS	34.02529	-118.25773	Plan check for PV roof mounted system. System size: 6.24kW with  24 modules and 24 microinverters Enphase M-215-6002LL-S2X-IG.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72737	18041-20000-19907	10201 W PICO BLVD 18	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/30/2018 12:00:00 AM			PC Approved	05/30/2018 12:00:00 AM	ADDRESS	34.04994	-118.41129	Interior remodel/change of use from office space to cafe in (E) commercial building.  Plan check for Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72738	15041-10000-19635	900 N ALAMEDA ST 3rd FLR	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.05855	-118.23671	Full plan check for a telecommunication data center with MEDIUM VOLTAGE., electrical room T.I  located in the 3rd floor ; Main scopes includes (2) new medium voltage sections, (2) 2500KVA transformers, and (2) 480V distribution boards.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72739	13041-10001-32988	17212 W LITHUANIA PL	91344	12	219B133   302	2608020023	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.29795	-118.50804	Expedited RSES plan check per applicant request.[][]PV1, Install  5.5 kw DC roof-mounted solar array for a one story house, interconnect with the main service panel. (1)Transformerless inverter(s): SolarEdge SE5000A-US. (22)modules: Trina Solar TSM-250PA05.18.[][]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72740	18041-10001-32127	6150 N LAUREL CANYON BLVD BLDG H	91606	2	177B165   349	2334011027	(T)(Q)C2-1-SN	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	02/07/2019 12:00:00 AM	ADDRESS	34.18223	-118.39491	PC ONLY, Supplemental submittal to merge building H and J under one plan review per fire department. Building J is under application # 18041-10000-34660 / E18LA04070. Scope of work includes New Fire Alarm System with future networking circuits for future buildings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72741	18041-10000-33448	633 1/2 W 83RD ST	90044	8	099B201  1363	6032022014	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM			Corrections Issued	08/31/2018 12:00:00 AM	ADDRESS	33.9633	-118.2852	PV1 3.8KW AC / 4.1KW DC  roofmounted system with (18) modules and (1) 3.8KW inverter interconnecting through the service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72742	19041-20001-10839	7337 N NITA AVE	91303	3	186B101   754	2023027007	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2019 12:00:00 AM			PC Approved	05/02/2019 12:00:00 AM	ADDRESS	34.20394	-118.61376	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414PLAN CHECK ONLY. SUPPLEMENTAL CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. MINOR DETAIL CHANGE ON PLANS, METER RELOCATION*ORIGINAL*Plan check for PV roof mounted system, system size: 10.15KW DC, 9.0KW AC with 35 PV Modules and 1 inverter(9.0KW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72743	13041-10000-10684	10640 W RIVERSIDE DR	91602	4	165B177   104	2423003034	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			04/25/2013 12:00:00 AM	07/16/2013 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.15205	-118.36286	PV2 11.52KW. 48 MODULES&MICROINV ON NEW CARPORT STRUCTURE. verify the btrc .(48) enphase m215-60-2LL-S22 microinverters. (48) SHARP ND-240QCJ PV SOLAR MODULES. on a new carport structure. construct carport sturcture with four posts and footings and which covers 920SF. install associated junction boxes, conduit, conductors and grounding. install (1) combiner subpanel, 1 square D DU222RB AC disconnect and install OCPD in existing panel	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72744	13041-20001-31244	7527 W WOODROW WILSON DR	90046	4	156B177   259	5570010008	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2013 12:00:00 AM			PC Approved	11/19/2013 12:00:00 AM	ADDRESS	34.12425	-118.3599	New rooftop UNGROUNDED PV Sytem for an existing single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72745	14041-20001-34044	16212 W SHADOW MOUNTAIN DR	90272	11	132B121   395	4420039009	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM			PC Approved	12/22/2014 12:00:00 AM	ADDRESS	34.05627	-118.53894	Expedite per applicant request.((PV1 system roof mounted with the system size: 12.7kW and 53 modules with 1 inverter and 1 load center.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72746	16041-30001-23417	19242 W DUNURE PL	91326	12	219A119   226	2820009011	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM			PC Approved	07/21/2016 12:00:00 AM	ADDRESS	34.29277	-118.55298	EXPEDITE PER REQUESTPV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72747	17041-10000-23192	12100 W WILSHIRE BLVD #1820	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	09/18/2017 12:00:00 AM	ADDRESS	34.0438	-118.46755	TITLE 24 PLAN CHECK ONLY FOR (T.I. FOR EXISTING OFFICE (SUITE # 1820)) -  TOTAL AFFECTED AREA 5036 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72748	13041-20000-14674	13270 N JACOB LN	91342	7	225B157  1031	2510019060	(T)(Q)RD1.5-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	PIN	34.3119349	-118.42618227	PV1 MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE: 3.24 KW. 15 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72749	14041-10000-26776	20970 W WARNER CENTER LANE	91367	3	174B109   231	2149017010	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.17478	-118.59087	T24, TI, OFFICE BUILDING. TENANT IMPROVEMENT, NO CHANGE IN OCCUPANCY. TOTAL AREA 2000 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72750	11041-20000-13395	5555 E VALLEY BLVD	90032	14	139-5A237  83	5220034002	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.00	Electrical	Electrical	Commercial			06/28/2011 12:00:00 AM	06/28/2011 12:00:00 AM		Permit Finaled	08/01/2011 12:00:00 AM	ADDRESS	34.07489	-118.16218	T24 ENERGY (GENERAL/EMERGENCY) LIGHTING CHANGE OF USE, CONVERT MAINTENANCE SHOP TO CAFETERIA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72751	18041-10002-02140	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/06/2019 12:00:00 AM			PC Approved	03/06/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	Change to approved set by modifying minor change on the floor plan. All changes under delta-ASI-05.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72752	15041-10000-12612	838 N HUDSON AVE	90038	4	141B185    87	5533026015	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Apartment			04/27/2015 12:00:00 AM	10/06/2015 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.08643	-118.33194	NEW APARTMENT BUILDING, PC FOR POWER AND ENERGY FOR NEW 4 STORY, 11 UNIT APARTMENT BUILDING. TOTAL SQ FT. 10000	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72753	11041-10000-26961	2121 S AVENUE OF THE STARS 100	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	04/03/2012 12:00:00 AM	ADDRESS	34.05554	-118.41342	CHANGE OF USE FROM OFFICE TO RESTAURANT AND TI - TENANT BUILD OUT OF A RESTAURANT; MEP WORK 3740 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72754	16041-30000-09892	10000 S WESTERN AVE	90047	8	091-5A193  74	6059001033	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Finaled	01/30/2018 12:00:00 AM	ADDRESS	33.94524	-118.30881	Replace fire alarm system in charter high school.  Total system size = 43 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72755	15041-20000-12316	6160 N ETHEL AVE	91401	2	177B161   422	2331017023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.01	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.18279	-118.41805	Plan check for PV roof mounted system 8.5 kWac with 32 modules(SUN POWER SPR-327 NE WHT D) and 2 inverter(POWR ONE PVI 3.0 AND PVI 5.0). Load calculation is included.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72756	15041-20000-20538	23034 W OXNARD ST	91367	3	177B097   508	2041022018	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.17906	-118.62875	$0 permit fee due to senate bill 1222 from 2012PV1. Install roof mounted PV system sized 12 kW. Interconnected with main service panel. (55) Kyocera KU2656 Modules(2) Solaredge SE6000A Inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72757	18041-20000-03021	100 W WORLD WAY Space 166	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/25/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	PIN	33.94684048	-118.40128468	TI for new tenant space (Beaming), plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72758	15041-20001-30183	19600 W WELLS DR	91356	3	171B117   372	2175011004	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2015 12:00:00 AM			PC Approved	10/05/2015 12:00:00 AM	ADDRESS	34.16395	-118.56074	10/05/2015 Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (36) modules, (36) power optimizers, and (1) combiner box. Standard plan is not being used.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72759	19041-10000-31625	110 E 9TH ST 6TH FL	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/13/2019 12:00:00 AM	08/19/2019 12:00:00 AM		Permit Finaled	07/29/2021 12:00:00 AM	ADDRESS	34.04107	-118.25479	Energy plan check for a partial office T.I located on the 6th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 15,814-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72760	19041-20000-24005	12919 W VICTORY BLVD	91606	2	180B161  1034	2326016018	[Q]C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	34.18684	-118.41451	T24 PLAN CHECK FOR TI WORK IN EXISTING MCDONALDS. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 1700 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72761	15041-10002-24189	8731 S LINCOLN BLVD	90045	11	096B161   737	4119026038	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	04/15/2016 12:00:00 AM		Permit Finaled	05/06/2016 12:00:00 AM	ADDRESS	33.95818	-118.41793	3/14/16: Changes to approved set noted on Delta-8 and Delta-9. Added (1) 100 A panel,  (24) circuits, (1) motor, added few light fixtures, updated T-24 forms.  (((02/03/2016Changes to an approved set of plans, note changes on delta 5,6 and 7. Changes include the addition of circuits, panels and changes to T-24. ((Full plan check for interior remodeling; Scope include new lighting, eqpuipment and receptacle. Total (10) panels, (100) circuits, and 27,284-SQ feet.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72762	19041-10000-28939	2911 W EXPOSITION PL Units 1	90018	10	117B185  1312	5044011026	CM-1-SP, RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			07/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.02047	-118.32807	Plan check for a PV2 3.00kw AC / 2.6KW DC  roofmounted system with (1) inverter and  (8) modules interconnecting through the main service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72763	11041-10000-06334	8510 N BALBOA BLVD 250	91325	12	192B133    87	2689019011	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.2251	-118.50158	T.I.  SUITES 175 & 250.  TITEL 24 PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72764	19041-10001-32408	11566 W KELSEY ST	91604	2	162B169   345	2368007020	RE11-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.14179	-118.38468	ADDING PV DISCONNECT PER ELECTRICAL INSPECTOR CORRECTIONPERMIT FEE IS $ 0 PER SB 1414(((((PV1, new rooftop mounted system, system size is 15.2 KWdc/ 10KWac. Scope of work is 50 modules (Seraphim SEG -305-6MB-BB) with optimzers (SE P320) , and a central inverter (SE 10000H-US). No panel upgrade	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72765	14041-10000-10865	6255 W SUNSET BLVD #1720	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM			PC Approved	05/01/2014 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for energy only. Permit pulled under 14041-10-09245. Emergency lights installed in high rise building. Interior T.I. to include erection of partition walls and remodel of ceiling. (1,552 SF)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72766	15041-10001-02906	15300 W VENTURA BLVD	91403	4	168B145   952	2276039007	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM			PC Approved	02/06/2015 12:00:00 AM	ADDRESS	34.15368	-118.4665	Change to approve set of plan. relocate the panel  to storage room and 1 module(((Plan check over the counter. Fire Alarm plan check. NOT a public school. Restaurant.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72767	14041-10000-19204	500 S VIRGIL AVE	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM			Reviewed by Supervisor	08/07/2014 12:00:00 AM	ADDRESS	34.06492	-118.28687	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT TO MEDICAL OFFICE (SUITE 303). BUILDING P# 14016-10000-12320.***BEGIN PRINT: 331285 (8/13/14 10:13)Application Number: 14041 - 10000 - 19204Address: 500 S VIRGIL-----------------------------------------------NO: 108470  -- ElectricalINVESTIGATION FEES DUE - work without permit for:Need to obtain permit for alteration to plumbing, relocation ofsinkNOTE: INVESTIGATION FEES ARE A MINIMUM $400.00 OR DOUBLE THEPERMIT FEE WHICHEVER IS GREATER.  See LAMC Section 91.107.5.1. Payment of investigation fees due at time of permit issuance. ORDER TO COMPLY ISSUED:  10/01/2012INSPECTOR:  PIERRE VEGA PHONE:  0000000(Created: PVEGA / 10-01-12)~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~***END PRINT: 331285 (8/13/14 10:13)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72768	11041-10000-02958	5550 W WILSHIRE BLVD #  101C	90036	4	132B181  1299	5089005***	[Q]C2-1-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	05/25/2011 12:00:00 AM		Permit Finaled	08/31/2011 12:00:00 AM	ADDRESS	34.06206	-118.34979	RESTAURANT AS FIRST TIME TENANT IN NEW BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72769	12041-10000-11319	21255 W BURBANK BLVD 3RD FLR	91367	3	174B105    87	2149019018	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM			Plans on Hold	05/25/2012 12:00:00 AM	ADDRESS	34.17432	-118.59446	PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT ON 3RD FLR OF A 6-STORY HIGH RISE BUILDING. CORE AND SHELL PLAN CHECK UNDER #06041-20000-13460.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72770	13041-10000-27282	1777 N VINE ST 2ND FLR	90028	13	150A187   376	5546004027	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.10356	-118.32694	TITLE-24 PART 6, LIGHTING PLAN CHECK-ONLY FOR CLASSROOM. EXISTING PERMITS ALREADY PULLED UNDER #13041-10000-16966 & 13041-10001-16966. TENANT IMPROVEMENT WORK PERFORMED ON THE SECOND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72771	19041-10000-10843	621 W 152ND ST	90247	15	072B201    75	6120001017	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Expired	06/05/2023 12:00:00 AM	ADDRESS	33.89472	-118.28668	PLAN CHECK FOR POWER PROVIDING FEEDERS TO WOOD GRINGING SYSTEM MCC3 RATING AT 1200A, AND CONCRETE CRUSHER SYSTEM MCC1 RATED AT 600A, AND INERT SORTING SYSTEM MCC2 AT 100A, AND MATERIAL HANDLER.BLD # 18020-10000-03749	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72772	15041-20000-05694	16776 W HUERTA ROAD	91436	5	165B133   170	2291004001	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Issued	03/20/2015 12:00:00 AM	ADDRESS	34.15043	-118.49895	Plan check for new single family dwelling unit(2 story) with 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72773	17041-10000-02872	2600 W RIVERSIDE DR 1-120	90039	4	151-5A209 249	5438024023	RD2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Apartment			01/27/2017 12:00:00 AM	07/02/2019 12:00:00 AM		Issued	07/02/2019 12:00:00 AM	ADDRESS	34.10734	-118.25853	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW NEW 4-STORY, 120-UNIT APARTMENT, OVER TWO LEVEL SUBTERRANEAN PARKING GARAGE. SCOPE INCLUDES A NEW 5000A  120/208 3 PHASE 4 WIRE SERVICE, NEW DISTRIBUTION BOARDS, NEW PANELS, AND NEW CIRCUITS. TOTAL OF 10 TYPICAL UNITS. TOTAL AREA = 154580. B#16010-10000-00198	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72774	18041-10000-23550	6240 N SYLMAR AVENUE MALL	91401	6	177B153   320	2240010***	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Issued	07/20/2018 12:00:00 AM	ADDRESS	34.18359	-118.44639	PLAN CHECK FOR POWER ONLY - PLAN CHECK INCLUDES 800A DISTRIBUTION EQUIPMENT CONNECTED TO AN EXISTING SYSTEM FOR NEW CAR CHARGERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72775	12041-10000-15416	23401 W MAESTRO PL	91304	3	189B093   816	2027001030	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2012 12:00:00 AM	07/03/2012 12:00:00 AM		Permit Finaled	07/17/2014 12:00:00 AM	ADDRESS	34.21002	-118.63886	New 10.56kw, rooftop photovoltaic systems for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72776	16041-10000-25319	1751 E BAY ST	90021	14	123A215   239	5166035***	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.03159	-118.23577	Plan check for T-24 only. Remove HID fixtures and replace with new LED fixtures. Total affected area: 37,296 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72777	19041-20000-50711	10795 N LAS LUNITAS AVE	91042	7	207B197   427	2566011053	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1011.22	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	01/27/2020 12:00:00 AM	ADDRESS	34.26532	-118.29213	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 7.37 KW DC/6 KW AC. SCOPE OF WORK CONSISTS OF (22) PV MODULES WITH OPTIMIZERS AND A 6 KW INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72778	14041-10000-02871	1458 S SAN PEDRO ST #L-26	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 630 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72779	19041-10000-24612	18362 W OXNARD ST BUILDING-4	91356	3	177B125   695	2157002134	M1-1	South Valley	Encino - Tarzana	Tarzana		1393.03	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/02/2020 12:00:00 AM		Permit Closed	04/26/2022 12:00:00 AM	ADDRESS	34.17985	-118.53311	PC (ENERGY ONLY) FOR CORE & SHELL-CHANGE OF USE FROM WAREHOUSE/OFFICE TO OFFICE. AREA OF SCOPE 27,175SF.FOR EXTERIOR LIGHTS IN BUILDING 4 .INCLUDING NEW PANEL AND CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72780	15041-10000-33459	8821 S PERSHING DR # 1	90293	11	093B153   150	4117028029	R2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	33.9532	-118.44046	PV1, INSTALL NEW 5.3 KW DC ROOF-MOUNTED SOLAR ARRAY ON #1 UNIT APRTMENT OF AN APARTMENT BUILDING.(20) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-3.6-OUTD-US-Z-ANote. Application should be under residential instead of commercial	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72781	10041-10000-16498	1930 W WILSHIRE BLVD	90057	1	132A203    41	5142002019	C4-2	Central	Westlake			2089.02	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.05713	-118.27464	INSTALL A NEW 230KW PV SYSTEM IN THE PARKING AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72782	17041-20001-45582	16633 W OAK VIEW DR	91436	5	168B137   395	2289020013	R1-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.15694	-118.49746	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.10.4kW ungrounded pv system. (2) 5.2kW inverters.(36) 300W pv modules. (2) 5kW Tesla Powerwall 2s.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72783	11041-10000-00261	7900 S LOYOLA BLVD	90045	11	099B161     3	4113001004		West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	Commercial			10/13/2010 12:00:00 AM			PC Approved	12/02/2010 12:00:00 AM	ADDRESS	33.96604	-118.41693	"TI REMODEL IN ""PEREIRA HALL SOUTH"" BUILDING IN LOYOLA MARYMOUNT UNIVERSITY:   PARTTIIONS, DOORS, CEILINGS, FINISHES IN AN EXISTING SCHOOL. PLAN CHECK FOR POWER AND ENERGY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72784	19041-10000-45472	7833 N HASKELL AVE	91406	6	189B141   193	2206002033	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Issued	04/17/2020 12:00:00 AM	ADDRESS	34.21321	-118.47511	INSTALLING A NEW INDOOR 2,000AMP SERVICE TO REPLACE THE DAMAGED OUTDOOR SRVICE EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72785	16041-10000-19794	9135 W LEANDER PL	90210	4	153B165   323	4388018017	RE15-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Expired	07/30/2018 12:00:00 AM	ADDRESS	34.11417	-118.39514	$0 fee due per California Senate Bill 1222.PV1. NEW SOLARSYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE 12.0KWac.(50)MODULES-KYOCERA# KU2656ZPA(2)INVERTER-ABB # PVI-6000-OUTD-US--Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72786	11041-10000-06713	1313 N VINE ST STUDY--VAULT 3	90028	13	147A187   357	5546019013	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.09511	-118.32681	interior tenant improvements from the basement to the roof; new luminaires in vaults( storage areas) ; 2 ea new panel boards and cktsPLAN CHK IS FOR TITLE 24 ENERGY COMPLIANCE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72787	14041-10000-26721	7454 1/2 W BEVERLY BLVD	90036	5	138B181   471	5512008001	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	10/02/2014 12:00:00 AM		Permit Finaled	03/25/2015 12:00:00 AM	ADDRESS	34.07596	-118.35248	Title 24 energy plan check.  Code based on 2008 and no change in occupancy. Newly connected load < 400 amps, indoor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72788	14041-10001-13821	6835 N BELLAIRE AVE	91605	2	183B161   828	2324015018	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	34.19493	-118.40958	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 3.825 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL, WITH OPTIMIZER AND TRANSFORMERLESS INVERTERS.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72789	12041-10000-31018	21514 W SATICOY ST	91304	3	186B105   164	2111005005	(T)(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Apartment			12/27/2012 12:00:00 AM			PC Approved	10/16/2013 12:00:00 AM	ADDRESS	34.20807	-118.59943	new building. 27 appartment units. lot area 21832 sq ft.  pLAN CHECK FOR POWER AND ENERGY.  FA VARIANCE WAS SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72790	16041-10000-41096	7077 W WILLOUGHBY AVE	90038	4	144B181   814	5531015001	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Apartment			11/22/2016 12:00:00 AM	07/10/2017 12:00:00 AM		Permit Finaled	09/25/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	FULL PC FOR POWER AND ENERGY  FOR A NEW 7 STORY MIXED USE BLDG.:  169 UNIT APARTMENT WITH RETAIL AND PARKING. SCOPE INCLUDES A NEW 4000A 277/480V 3 PHASE, 4 WIRE DISTRIBUTION BOARD/SERVICE, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. THERE ARE 11 TYPES OF APARTMENT UNIT PANELS. TOTAL AFFECTED AREA IS 160530 SQ. FT. B#16010-10000-03070Fire alarm modification was filed with the department 4/5/2017.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72791	10041-20000-04839	6801 W HOLLYWOOD BLVD D3-333	90028	13	148-5A185 402	5548004062	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM			PC Approved	03/17/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907	energy plan check hot topic	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72792	14041-10000-01837	1101 S FAIRFAX AVE	90035	10	132B177  1022	5086002034	R4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			01/22/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	04/08/2014 12:00:00 AM	PIN	34.05564949	-118.36531499	PLANCHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK TO BE INDOORS. 1632 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72793	16041-10000-22116	1110 W VERNON AVE	90037	9	111B197   154	5017017008	[Q]R4-1	South Los Angeles	South Los Angeles	Voices of 90037		2322.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.00352	-118.29428	Installation of a new PV1 solar system incterconnected with the main house panel. Total number of (20) microinverters rated at 215 watts. Total size system size is 5.2KWdc / 4.3KWac.(20)Modules-HiS-S260MG(20)Microinverter-Enphase M215-60-2LL-S22-IG(1) 125 A load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72794	18041-10000-12190	767 S ALAMEDA ST	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	04/10/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	PLAN CHECK FOR TITLE 24 ONLY FOR ADDITION OF TWO NEW RESTROOMS IN AN EXISTING PENTHOUSE ON TOP OF A MIXEDUSE BUILDING TOTAL AFFECTED AREA 232 SQ. FT.(NON HIGH RISE BUILDING)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72795	17041-10000-17165	6001 N VAN NUYS BLVD	91401	6	177A151    92	2241027004	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Issued	05/23/2017 12:00:00 AM	ADDRESS	34.17961	-118.44899	PC for energy only, Outdoor Title 24. Removing HID fixutres and replacing them with new LED fixtures. Area: 80,950 sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72796	17041-10000-19786	520 S LA FAYETTE PARK PL	90057	1	135A201   136	5155019007	CR-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	08/30/2017 12:00:00 AM		Issued	08/30/2017 12:00:00 AM	ADDRESS	34.06376	-118.28241	PC FOR ROOFTOP PV ON COMMERCIAL BUILDING. SYSTEM IS RATED 140KW AC USING 5 INVERTERS TOTAL, 497 MODULES AND POWER OPTIMIZERS. NET METERED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72797	16041-10000-00530	13052 N DRONFIELD AVE	91342	7	222B153    31	2509020002	(Q)R3-1	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Apartment			01/07/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	34.30805	-118.43722	PC FOR A NEW FIRE ALARM SYSTEM TO A NEW 3-STORY 44-UNIT APARTMENT BUILDING W/ BASEMENT GARAGE. SCOPE INCLUDES 118 FIRE ALARM DEVICES, 1 FIRE ALARM PANEL, AND 1 COMMUNICATION PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72798	17041-10000-05270	1601 S GRANDE VISTA AVE	90023	14	117A223    36	5169002017	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.01628	-118.20912	PC for indoor Title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 23,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72799	11041-20000-04235	2614 W 7TH ST	90057	1	133-5A201 297		C2-2, R4-2	Central	Westlake	MacArthur Park		2094.01	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	11/16/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	New 70.56 KW P.V. system mounted on a roof of a new building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72800	18041-20002-07899	13636 W BAYLISS ROAD	90049	11	138B133   166	4492016006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.07617	-118.50755	INSTALL BATTERY BACK-UP SYSTEM - SCOPE INCLUDES NEW LG CHEM ENERGY STORAGE SYSTEM RATED AT 9.8KWH, CRITICAL LOAD PANELBOARD, AND EV CHARGING STATION.PV UNDER 18041-20000-07899	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72801	15041-20000-15804	6324 N CANOGA AVE	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.18512	-118.59722	Title 24 plan check only.  Total area = 2,090 sq. ft.  T.I. to existing commercial space.  Change of use from restaraunt to office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72802	17041-10000-36529	6101 W CENTURY BLVD	90045	11	090B169     4	4124030036	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	33.9457	-118.39149	Plancheck for coffee shop TI for title 24 energy only total effect of the area 950 s/f scope includes new panel circuits lighting and equipments B#17016-30000-19900INTERIOR TENANT IMPROVEMENT for existing starbucks coffee shop at Sheraton hotel lobby	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72803	13041-20001-19104	5890 W HOLLYWOOD BLVD	90028	13	148-5A191 180	5545004004	[Q]C4-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			11/12/2013 12:00:00 AM			PC Approved	11/12/2013 12:00:00 AM	ADDRESS	34.10151	-118.31777	((Changes made to approved set of plans. Plan check only application))T24 FOR EXISTING GAS STATION CONVENIENCE STORE. SCOPE OF WORK ONLY IN CONVENIENCE STORE AND REPAIR GARAGE. 2305 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72804	18041-10001-30000	1555 N VAN TRESS AVE PV1	90744	15	036B201   854	7414020046	R1-1XL	Harbor	Wilmington - Harbor City	Wilmington		2943.01	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	33.79433	-118.27953	Plan check for reinstall an exiting PV system due to re-roofing.(Ref, PV permit# 13041-20000-18208/ 13041-20001-18208)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72805	17041-20000-43281	229 N BURLINGTON AVE #4	90026	13	136-5A207 286	5159006009	RD1.5-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM			Reviewed by Supervisor	01/12/2018 12:00:00 AM	ADDRESS	34.06717	-118.26626	plan check for power only.NEW 4 STORY SINGLE FAMILY DWELLING W/ ATTACHED GARAGE. (PART OF NEW SMALL LOT SUBDIVISION). 4 of 6 units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72806	12041-10000-05193	4610 S MAIN ST	90011	9	112-5A205 326	5109002027	C2-1VL	South Los Angeles	Southeast Los Angeles			2285.00, 2319.00	Electrical	Electrical	Commercial			03/07/2012 12:00:00 AM	04/25/2012 12:00:00 AM		Permit Finaled	10/02/2012 12:00:00 AM	PIN	34.00121161	-118.27359852	NEW 2 STORY TYPE VB CHARTER HIGH SCHOOL BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72807	19041-10000-17397	15287 W SUNSET BLVD	90272	11	129B125   862	4423016077		West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/09/2019 12:00:00 AM	06/18/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.04723	-118.52537	PC for energy only (tailor method employed). scope of work is 2,629SF. Change of use to retail store	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72808	17041-10000-36932	5850 W 3RD ST unit A,B	90036	4	135B181   171	5509002015	C2-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	12/26/2017 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.06907	-118.34746	PC FOR RESTAURANT TI  FOR TITLE 24  ENERGY ONLY.SCOPE INCLUDS NEW CIRCUITS LIGHTS AND EQUIPMENT. TOTAL AFFECTED AREA 1609SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72809	13041-10001-06029	1333 N WATERLOO ST	90026	13	141A207   127	5424023005	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			06/03/2013 12:00:00 AM			PC Approved	06/03/2013 12:00:00 AM	ADDRESS	34.08138	-118.26534	MODIFICATION TO APPROVED SET OF PLANS. CHANGE FROM TRINA SOLAR # TSM-240PA05 TO TRINA SOLAR # TSM-245PC05.****************************************************************PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. THIS APPLICATION IS PART OF A SERIES OF 3 APPLICATIONS. TOTAL SYSTEM SIZE 1.68 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72810	19041-10000-08880	710 W ANAHEIM ST	90744	15	030B205   473	7416020006	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.10	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	04/29/2021 12:00:00 AM	ADDRESS	33.77939	-118.27064	PC FOR SERVICE UPGRADE FROM 100A TO 600A, 120/240V, 3W, 1PH. AREA OF SCOPE 3440SQFT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72811	15041-10000-39660	915 W WILSHIRE BLVD #2000	90017	14	130-5A209 153	5144007040	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.05069	-118.2599	TI TO OFFICE SPACE. NEW LIGHTING. PC FOR T24 ENERGY ONLY. BUILDING PERMIT 15016-10000-21836	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72812	19041-20000-21327	20700 W SESNON BLVD #171	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2019 12:00:00 AM	06/05/2019 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.29545	-118.58467	Plan check for a PV1 roof-mounted PV system. System size is 5.03 kWdc/4.8 kWac and consists of (15) AC PV modules and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72813	18041-20000-24223	2440 N VERMONT AVE	90027	4	153B197   193	5588028010	RE11-1	Central	Hollywood	Los Feliz	YES	1891.02	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Expired	05/15/2024 12:00:00 AM	ADDRESS	34.11537	-118.28988	Installation of 40.5 kWh energy storage system for SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72814	12041-10000-24283	18855 W VICTORY BLVD	91335	3	180B121   391	2127001014	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			10/11/2012 12:00:00 AM			PC Approved	10/11/2012 12:00:00 AM	ADDRESS	34.18675	-118.54436	Exterior site lighting. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72815	13041-20000-26631	6080 W CENTER DR SUITE 500	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/26/2013 12:00:00 AM	ADDRESS	33.97713	-118.39172	T24 FOR EXISTING GOLF STORE. INSTALLING 6 NEW LIGHTS AND SOME RECEPTACLES. 900 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72816	14041-10000-21981	416-418 E BOYD ST	90013	14	129A213   355	5147006001	M2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	34.04606	-118.24212	Title 24 plan check only.  Total area = 3,650 sq. ft.T.I. to existing coffie shop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72817	13041-20000-22296	2603 W SAN FERNANDO ROAD	90065	1	150B213   379	5457007001	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			Corrections Issued	08/16/2013 12:00:00 AM	ADDRESS	34.10877	-118.2411	Plan check for energy and outdoor lighting. Indoor and outdoor lighting. Patio Futures  LLC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72818	12041-10000-30782	12751 W MILLENNIUM A	90094		102B161  1175	4211033020		West Los Angeles					Electrical	Electrical	Apartment			12/21/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	PLAN CHECK POWER AND ENERGY FOR BUILDING A. FIRST LEVEL RETAIL WITH 3 STORY OF 96 UNITS RESIDENTIAL BUILDING ON TOP OF COMMON SUBTERRANEAN PARKING GARAGE. SITE LOCATED IN METHANE ZONE. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72819	13041-10000-34311	735 W BATTERY ST 1-4	90731	15	021B197   300	7445008050	M1-1VL	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	12/02/2014 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	33.7545	-118.29317	Plan check for power and energy for a first time new building, 4 suite with the house panel. Title 24 for indoor and outdoor with area 22588 sq ft that include the facad of the building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72820	16041-20000-08840	5161 N VAN NUYS BLVD	91403	4	171A151    54	2263034012	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	06/22/2018 12:00:00 AM	ADDRESS	34.16462	-118.4489	Conversion of (E) gas station commercial building into foodmart.  Plan check for power and energy.  Gasoline dispensers are (E) to remain, power reconnected.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72821	18041-10001-05201	577 N GREENCRAIG ROAD	90049	11	135B141   175	4403019019	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Issued	06/21/2018 12:00:00 AM	ADDRESS	34.06861	-118.48064	Fees are $0 due to senate bill 1222.6-21-18, an addition of an LG  battery unit to a PV system. (1)LG CHEM-LGC-RESU-10H	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72822	11041-20000-06979	21700 W OXNARD ST 11th floor	91367	3	177B105    82	2146006047	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM			PC Approved	04/07/2011 12:00:00 AM	ADDRESS	34.17901	-118.60179	T.I. to existing high rise building in 11th floor.  Install general/emergency lighting in elevator lobby and open office 1140 as shown on plans.  Plan check for energy only.Note:  Permit issued under 11041-20000-04176	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72823	17041-20001-36052	2343 N RIVERDALE AVE	90031	13	144B213   440	5445018021	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM			PC Approved	10/14/2017 12:00:00 AM	ADDRESS	34.09135	-118.23453	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system (roof-mounted array) with an AC coupled battery backup system for SFD.3kW unground pv system. (8) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each pv module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72824	10041-10000-06050	550 S HOPE ST #300	90071	9	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	04/02/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.04989	-118.25574	T.I. for existing  high rise building.  Install general lighting in conference area.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72825	15041-10001-40900	10866 W ART ST	91040	7	201B173   268	2542025010	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.24841	-118.36746	Expedite per applicant request.(((PV1 11.4KW AC roof mounted system with (37) SunPower X21-345 moulde, (1) combiner box and (1) Solaredge SE11400A inverter interconnecting through the main service panel.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72826	17041-10000-30741	3200 W 8TH ST	90005	10	132B197   490	5094017010	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM	09/12/2017 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.05758	-118.29798	CHANGE OF USE FROM LIQUOR STORE TO SMALL RESTAURANTNEW FEEDERS , PANEL BOARDS , AND CIRCUITSFULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72827	17041-10000-31814	18421 W VENTURA BLVD	91356	3	171B125    76	2160008032	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM	09/06/2017 12:00:00 AM		Issued	09/06/2017 12:00:00 AM	ADDRESS	34.16815	-118.53399	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 24250 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72828	16041-20000-20855	13972 W PAXTON ST	91331	7	207B153  1109	2618002027	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.03	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2016 12:00:00 AM	06/20/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.26506	-118.43765	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.1KW STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72829	17041-10002-36987	1460 W 27TH ST	90007	8	123B197  1350	5054032011	RD1.5-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			06/11/2018 12:00:00 AM	06/20/2018 12:00:00 AM		Permit Finaled	07/23/2018 12:00:00 AM	ADDRESS	34.03028	-118.29351	Supplemental to changes to approved set of plans - Scope includes clarifying existing equipment(200A Service replacement from 200A to 200A) and adding new 400a panel board to include PV load. Install new PV2 on 2 separate structures of an multi unit apartment, total system 22.3kW AC. using (97) modules with (97) microinverters, (1) 200A load center. Permit fees are $0 due to Senate Bill 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72830	18041-20000-23905	1244 W 39TH ST	90037	8	117B197   814	5037007001	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			06/26/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.01515	-118.29876	Plan check for new fire alarm system for 12 units appartment building. Total fire alarm devices: 83 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72831	16041-10000-03738	3017-3019 W VERNON AVE	90008	10	111B189   181	5023011008	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM			PC Approved	07/27/2018 12:00:00 AM	ADDRESS	34.00379	-118.32642	T-24,CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1500. 2008 T-24, BUILDING PERMIT 07016-10000-17315. Permit fees on 14041-70000-24646	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72832	13041-20000-09135	1680 N VINE ST	90028	13	148-5A189 136	5546029001	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM			PC Approved	04/09/2013 12:00:00 AM	ADDRESS	34.10133	-118.32648	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72833	17041-20001-03919	2484 E OLYMPIC BLVD	90021	14	121-5A219 158	5168002900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.0254	-118.22674	Supplemental Plancheck due to significant increase in the scope of work. Plancheck for power and energy. HAZARDOUS LOCATION. New 3000 amp service, 2 new 2000amp MCC's. Plan check for power and energy. Project site is a new administration building and adjoining parking lot for an asphalt plant. Total lighting area = 3,800 sq. ft.Note: Building application has been generated under 16010-10000-05743	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72834	15041-20000-26831	5647 N LUBAO AVE	91367	3	174B113   275	2153002016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Issued	11/19/2015 12:00:00 AM	ADDRESS	34.17356	-118.5675	PV1 SFD. TOTAL SYSTEM SIZE 12.2KW AC USING DOUBLE INVERTER SYSTEM. USING 60 MODULES IN TOTAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72835	14041-10000-22804	15537 W CABRITO ROAD	91406	6	189B145   113	2654040014	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.21729	-118.4712	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72836	14041-20001-35788	4409 N AZALIA DR	91356	3	165B121   135	2177014010	RE11-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2014 12:00:00 AM			PC Approved	01/05/2015 12:00:00 AM	ADDRESS	34.15125	-118.54068	Supplemental per customer request.PV1. Install roof mounted PV system sized 6.45 kW. Interconnected with main service pannel. (30) Sunmodule Plus SW270 Modules(30) Enphase M215 Microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72837	16041-10000-26608	1200 S BROADWAY Build. 12	90015	14	126A209   273	5139026011	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/28/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	34.03792	-118.26026	PC FOR A NEW FIRE ALARM. FIRE ALARM SYSTEM IS FOR A  NEW 7-STORY, 200 UNIT APARTEMENT BUILDING . SCOPE INCLUDES 911 FA DEVICES, 9 FA PANELS.*BUILDING LOCATED ON METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72838	17041-30000-23228	350 S GRAND AVE Suite 2300	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Permit Finaled	09/13/2017 12:00:00 AM	ADDRESS	34.05173	-118.2522	Plan check for Title 24 only. Project site is a portion of the 23rd floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 1,760 sq. ft.Note: Building permit has been issued under 17016-10000-15853	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72839	13041-10000-28444	1036 S NORTON AVE	90019	10	129B189   219	5081010007	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Apartment			10/11/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	ADDRESS	34.05283	-118.32105	pc for power and energy. NEW 3-STORY TYPE III-A 22 UNITS APARTMENT OVER ONE LEVEL TYPE I-A PARKING GARAGE (10010-10000-02356). Methane Buffer Zone. fire alarm variance filed on 10/11/2013 and paid-mt	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72840	18041-10000-48440	544 S STANFORD AVE	90013	14	126A213    25	5147019005	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.04138	-118.24205	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72841	19041-10000-02861	2025 S AVENUE OF THE STARS podium lev	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/24/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	09/29/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	FULL PLAN CHECK FOR POWER AND ENERGY. NEW 600A DISTRIBUTION BOARD, PANELS AND EQUIPMENTS. TOTAL AFFECTED AREA = 152,714 SF. MAIN SERVICE UNDER PERMIT 18041-10000-05560.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72842	19041-20000-31838	3740 W 58TH PL	90043	8	108B185  1081	4004008010	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	33.98795	-118.3393	PV1. INSTALL (6) NEW MODULES WITH MICROINVERTERS ON EXISTING PV SYSTEM. SYSTEM SIZE IS 4.34KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72843	15041-20000-04724	18929 W GRANADA CIR	91326	12	216B121   424	2872010035	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	05/18/2016 12:00:00 AM	ADDRESS	34.28659	-118.54566	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH  MSP.(35) CANADIAN SOLAR 255/235 MODULES(35) SOLAR EDGE OPTIMIZERS P300(1) SOLAR EDGE INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72844	16041-20000-30645	20234 W STAGG ST	91306	3	189B113  1256	2114003032	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	10/01/2016 12:00:00 AM	ADDRESS	34.21064	-118.57426	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.42 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72845	16041-10000-40608	823 W CENTURY BLVD	90044	8	091-5A199  96	6054008011	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	33.94566	-118.29021	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.0KWac.(24)MODULES-AXIPOWER AC265P/156-60S(1)INVERTER-FRONIUS PRIMO 6.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72846	11041-20000-01165	4216 W FOUNTAIN AVE	90029	13	147A201   248	5429008029	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Griffith Park	YES	1954.00	Electrical	Electrical	Commercial			01/20/2011 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	02/02/2012 12:00:00 AM	ADDRESS	34.09566	-118.28135	T.I. to existing building.  Permit for 400amp services, panels, branch circuits.  Install new general/emergency lighting in partial of first floor and entire second floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72847	18041-20000-46197	19652 W TRULL BROOK DR	91356	3	162B117   376	2180017003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM	12/05/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.13716	-118.56132	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72848	15041-10000-21311	8436 W 3RD ST 6th Floor	90048	5	138B173   806	5511032058	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM			PC Approved	07/07/2015 12:00:00 AM	ADDRESS	34.07301	-118.37448	Energy plan check for a MRI equipment office addition, located in the 6th floor of a high rise building. Total area is 1506-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72849	14041-20000-00630	12866 W MACNEIL ST	91342	7	222B161   428	2525024030	RS-1	North Valley		Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	03/11/2014 12:00:00 AM	ADDRESS	34.30227	-118.41339	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 KW AC USING 14 MODULES. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72850	18041-10000-12543	700 S FLOWER ST 19TH FLR	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COMMERCIAL OFFICE.  8931 SQFT. HIGH RISE. 19TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72851	13041-10000-07298	415 S LA BREA AVE	90036	4	135B181   428	5508006028	C2-1	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.06635	-118.34436	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING LOW RISE RETAIL SPACE. THE 2000 AMP SERVICE WAS APPROVED UNDER SHELL AND CORE.  SQRFT 44,086.  THERE WAS SUBMITTAL UNDER 13041-10001-07298 TO COVER SOME CHANGES ( PLAN CEH ONLY) PERMIT IS UNDER THIS 13041-10000-07298.  fIRE ALARM IS UNDER SEPERATE PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72852	11041-10001-22455	3900 N STANSBURY AVE	91423	5	162B153   353	2274027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1417.00	Electrical	Electrical	Public Safety Only			03/01/2012 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	09/20/2013 12:00:00 AM	ADDRESS	34.14084	-118.44264	Fire alarm for a private school.  77 new fire alarm devices to be installed and one new panel. ((((additionof 10 devices to existing approved set  3-1-12)))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72853	17041-20000-34927	213 S FRESNO ST	90063	14	124-5A227  58	5179005037	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2041.10	Electrical	Electrical	Apartment			09/28/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.03691	-118.20021	Plan check for solar pv system, roof-mounted array on 3-unit apartment.3kW ungrounded system. (8) 300W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72854	17041-20000-40601	16640 W PARTHENIA ST	91343	12	195B137   831	2689021003	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.22831	-118.49545	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and  consists of (2) inverters, (34) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72855	17041-20001-35820	10828 W PEACH GROVE ST	91601	2	168B173   302	2421013007	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.1589	-118.36682	EXPEDITED PER APPLICANTS REQUEST.ENERGY STORAGE SYSTEM + PV1 ROOFMOUNTED PV SYSTEM. SYSTEM SIZE: 3.8 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72856	15041-10000-29932	9767 N GLENOAKS BLVD STE D	91352	6	201B169    89	2537022012	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/10/2015 12:00:00 AM		Permit Finaled	09/24/2015 12:00:00 AM	ADDRESS	34.24699	-118.38486	T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (WAREHOUSE). SCOPE INCLUDES REPLACING HID LIGHT FIXTURES WITH NEW LED FIXTURES. TOTAL AREA IS 1544 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72857	18041-20000-37877	5990 N SEPULVEDA BLVD #460	91411	4	177B145   487	2243019023	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/04/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.17911	-118.46588	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72858	14041-10000-09555	3001 W PEAK PL	90065	13	154-5A215 619		RD2-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1864.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.11862	-118.23815	SFD ROOF-MOUNTED 1.3KW PV SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72859	11041-10000-13987	6600 N TOPANGA CANYON BLVD 2100	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/06/2011 12:00:00 AM			PC Approved	08/31/2011 12:00:00 AM	ADDRESS	34.19008	-118.60565	TI TO AN EXISTING RETAIL SPACE, FOOTLOCKER IN TOPANGA PLAZA.  T-24, TAILORED METHOD.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72860	19041-10000-42104	1150 S OLIVE ST 1350	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	11/01/2021 12:00:00 AM	ADDRESS	34.03962	-118.26181	Energy plan check only. Scope of work area 639 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72861	13041-10000-34911	13292 W PAXTON ST	91331	7	213B157   649	2534002030	P-1, [Q]MR1-1	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.27617	-118.42249	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 6641 SQ FT. TOTAL OF (9) UNITS WILL BE REPLACED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72862	17041-20001-06588	11409 W PENROSE ST	91352	6	192B169   411	2632011012	M1-1-G-CUGU, M2-1-G-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM			PC Approved	01/10/2018 12:00:00 AM	ADDRESS	34.22308	-118.37994	1/10/2018changes to an approved set of plans.  changes are noted delta 4.  changes include updating plan to match field conditions.  this is plan check only.    (((((FULL PC FOR POWER AND ENERGY. TI TO (E) OFFICE/WAREHOUSE BUILDING. TOTAL CONNECTED LOAD > 400A. SCOPE INCLUDES ADDING A NEW 400A 120V/240V 3 PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 11323 SQ. FT.  B#16016-20000-11409)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72863	16041-10000-38236	11766 W WILSHIRE BLVD STE 1701	90025	11	129B145   734	4263008062	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.04	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.04804	-118.46227	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENTS TO THE 17TH FLOOR OF AN EXISTING HIGH RISE COMMERCIAL BUILDING WITH NEW OFFICES, PANTRY, CONFERENCE ROOMS, AND PHOTO STUDIO. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 9931 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72864	19041-20000-07717	1532 S BROCKTON AVE 1-29	90025	11	126B145   655	4263034036	R3-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Apartment			03/04/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	10/28/2021 12:00:00 AM	ADDRESS	34.04056	-118.46035	Plan check for power and energy new apartment building 1200 Amp 120/208 Volts Service. (29) units all typical. Total area: 33,034 fq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72865	11041-20000-14866	12051 W VENTURA BLVD	91604	2	162B165   105	2368002038	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	09/22/2011 12:00:00 AM		Permit Finaled	01/03/2012 12:00:00 AM	ADDRESS	34.14376	-118.39488	Ti in an existing Chase bank. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72866	17041-10000-06757	605 S IMPERIAL ST	90021	14	126A217   177	5164013012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM			Reviewed by Supervisor	03/22/2017 12:00:00 AM	ADDRESS	34.03784	-118.2317	PC FOR 600A SERVICE UPGRADE. INSTALL 2 MOTORS AND REFEED EXISTING PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72867	18041-20000-00660	110 W 11TH ST Ste 400	90015	14	126A209   182	5139017024	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/27/2018 12:00:00 AM	ADDRESS	34.0392	-118.25858	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72868	16041-10000-39305	6765 W SELMA AVE A2	90028	13	148-5A185 252	5547013015	C4-2	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM			PC Approved	05/02/2018 12:00:00 AM	ADDRESS	34.09981	-118.33796	NEW 5 STORY APARTMENT OF 1 LEVEL PARKING. NEW 38 UNIT. PC FOR POWER AND ENERGY.NOTE: PERMITS FOR BUILDING A1 & A2 WILL BE ISSUED UNDER PCIS#16041-10000-39315	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72869	10041-20001-09845	15031 W RINALDI ST canser-treatment	91345	7	213B145    64	2664022022	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills	YES	1091.00	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			PC Approved	07/21/2010 12:00:00 AM	ADDRESS	34.27918	-118.46029	Revision to approved set. Power conditioner moved to new location close to upgraded  linear accelerator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72870	14041-20000-30665	12180 W MILLENNIUM 1st, 2nd-floor	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	T.I. to existing building on the 1st and 2nd floors.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72871	19041-10000-23245	17401 W VENTURA BLVD	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Permit Finaled	03/23/2021 12:00:00 AM	ADDRESS	34.16136	-118.51189	Full plan check for a commercial building (Mall) T.I. Scope includes relocating equipment, adding new equipment and lighting on the floor plan with a total lighting area (in/outdoor) of 51,291-SQ FT. plan also includes (2) existing service of 1000-amp and 3000-amp with new load calcuation and fault current calculation on the single line diagram. (((FACADE RENOVATION OF (E)  (+/- 106,000 SQ/FT) COMMERCIAL BLDG AND UPGRADES TO (E) BUILDING SYSTEMS.  (2) NEW ELEVATORS, (N) EXTERIOR STAIRS AND INTERIOR ACCESS STAIRS.SEE COMMENTS)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72872	14041-20001-23920	12801 W DESMOND ST	91331	7	216B161   157	2527011028	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2014 12:00:00 AM			PC Approved	09/12/2014 12:00:00 AM	ADDRESS	34.2884	-118.41142	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 10kW.(2) Aurora PVI-5000-OUTD-S-US-A transformerless inverters(30) Sunpower 327W pv modules]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72873	15041-10001-25063	9742 W CRESTA DR	90035	5	129B165   862	4307018018	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.04698	-118.40022	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 12.985 KW DC ROO-MOUNTED SOLAR ARRAY ON A SINGEL FAMILY HOUSE.(49) MODULES: KYOCERA KYU2656ZPA(2) INVERTERS: ABB PVI-=5000-OUTD-US-Z-A>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72874	10041-20000-07078	7635 N AIRPORT BUSINESS PARK WAY	91406	6	186B137   425	2205009085	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	05/24/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.21004	-118.49556	single story warehouse. Plan check is for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72875	19041-20000-49810	5752 N LARRYAN DR	91367	3	174B089   108	2045022010	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.17586	-118.64839	Plan check for PV roof mounted system, PV system size: 7.475KW DC, 7.6KW AC with 23 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72876	14041-10000-01679	6851 W IMPERIAL HWY	90045	11	087B161    96	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/21/2014 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	33.93207	-118.40981	Tenant improvement of airport cargo space.  Plan check for compliance with Title 24 Part 6 requirements for changes to lighting system.  Scope of work for areas affected by Title 24 regulations total 1,833 s.f.  Electrical permit obtained under 14041-90000-00603.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72877	14041-20001-23622	5168 W MELROSE AVE	90004	4	141B193   612	5522007026	C2-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	08/08/2016 12:00:00 AM		Permit Finaled	08/26/2016 12:00:00 AM	PIN	34.08332684	-118.31320919	(8/4/16)CHANGES TO AN APPROVED SET OF PLANS.  REPLACEMENT OF PANELS A IN MSB AND C IN MSA ONE FOR ONE AND ADDITION OF PANEL B IN MSC WITH NEW LOADS.  PLAN CHECK FOR POWER AND ENERGY.  TI IN (E) RETAIL SPACE IN AN (E) URM HOTEL. CONVERTING THE RETAIL SPACE TO A LOUNGE BAR. ADDING A NEW MEZZANINE FOR EQUIPMENT STORAGE INSIDE BAR AREA.  A2 OCCUPANCY EXCEEDING 100 OCCUPANT LOAD.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72878	13041-10007-19659	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			02/02/2016 12:00:00 AM	02/02/2016 12:00:00 AM		Permit Finaled	06/23/2016 12:00:00 AM	ADDRESS	34.09918	-118.32644	02/02/16Changes to an approved set. Adding CO2 panels to existing house panels. Scope includes carbon monoxide detection system on a multi-use residential parking structure for levels B1-B4, and L1-L2.(((((SUPPLEMENTAL PERMIT FOR PERMIT #13041-10000-19659 TO ADD ELECTRICAL FOR PARKING GATES AND EQUIPMENT.  ELECTRICAL FOR MOTORIZED ROLL UP GATES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72879	17041-20001-42765	11853 N EDDLESTON DR	91326	12	216B125   161	2870023038	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	02/28/2018 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.28875	-118.53492	2/28/18changes to an approved set of plans.  changes to derate main breaker panel.   (((Plan check for solar pv system, roof-mounted array on SFD.8.4kW ungrounded system. (30) EnPhase IQ6PLUS-72.(30) 360W pv modules. Using standard plan.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72880	10041-20000-24375	8209 W MELROSE AVE	90046	5	141B173   399	5528006053	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM			PC Info Complete	12/08/2010 12:00:00 AM	ADDRESS	34.08385	-118.36837	T.I. for beauty salon on first floor.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72881	17041-20000-20482	725 S FIGUEROA ST Suite 1900	90017	14	129A207   336	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for energy only. TI to existing office suite 1900 in high rise building. New and relocated lighting. T24 area - 22,661sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72882	17041-20000-07875	11979 W WALNUT LANE 1-4	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.03749	-118.4591	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 FACP, 1 RPS  AND 53 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72883	13041-10001-01320	2500 S WESTERN AVE	90018	8	123B193   477	5058015005	C2-1, RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2215.00	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM			PC Info Complete	08/07/2014 12:00:00 AM	ADDRESS	34.03373	-118.30879	Plan check for power and energy (deltas 7 through 11 and plan check clouds). REVISIONS TO PERMITTED SET OF PLANS INCLUDING  ADDING A FIRE PUMP AND A JOCKEY PUMP AND CHANGES TO THE LIGHTING SYSTEM.NEW 4 STORY BUILDING FOR OFFICE USE AND 2 STORY UNDERGROUND PARKING GARAGE, 2 ABOVE GROUND PARKING AND 2 STORIES OF OFFICE. NEW 4000A SERVICE. PC IS FOR T24 AND POWER. TOTAL AREA OF 186542 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72884	16041-10000-43771	300 E ROSE AVE	90291	11	111B141   675	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	08/04/2017 12:00:00 AM	ADDRESS	33.99652	-118.47669	FULL PC FOR POWER AND ENERGY. INTERIOR TI TO 2 STORY OFFICE BUILDING. SCOPE INCLUDES ADDING NEW PANELS, NEW RECEPTACLES, AND NEW NEW LIGHTS. NEW CONNECTED LOAD > 400A. TOTAL AFFECTED AREA IS 14760 SQ. FT. B#16016-10000-28812	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72885	18041-30002-20864	6222 W WILSHIRE BLVD 400	90048	5	135B177   508	5088015***	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.06309	-118.36418	01/15/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.11/08/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. Changes have been made to the lighting floor plan and reflected onto the Title 24 forms.*****Previous Work Description*****PLAN CHECK FOR ENERGY (T24) ONLY, TENANT IMRPOVEMENT TO (E) OFFICE BUILDING STE.400. TOATL AREA: 12,165 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72886	15041-20000-27522	7817 N LANKERSHIM BLVD	91605	6	189B169   659	2310025031	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			08/21/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	01/18/2017 12:00:00 AM	ADDRESS	34.21268	-118.388	Plan check for PV roof mounted system in commercial building. System size: 14.4 kW with 44 modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72887	18041-10000-05928	7913 S KENTWOOD AVE	90045	11	099B165   197	4109018017	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2018 12:00:00 AM			Reviewed by Supervisor	03/05/2018 12:00:00 AM	ADDRESS	33.9703	-118.40209	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. , CONISIT OF 29 MODULES(#SC325) OPTIMIZERS(SOLAREDGE POWER OPTIMIZERS P400) AND  A CENTRAL INVERTER (SOLAREDGE #SE7600) . SYSTEM SIZE IS 7.6KWac AND 9.43KWdc.SCOPE INCLUDES NEW LOAD CENTER (125A ) AND NEW DISTRIBUTION PANEL(200A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72888	11041-20000-18465	1950 CENTURY PARK EAST	90067	5	132B161    21	4319001008	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/30/2011 12:00:00 AM			PC Approved	08/30/2011 12:00:00 AM	PIN	34.06062453	-118.41312336	PLAN CHECK T24 ENERGY/EMERGENCY FOR TI ON EXISTING SPACE AUTOMOBILE CLUB	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72889	19041-20001-44401	4813 N LOCKHAVEN AVE	90041	14	162A219   266	5683028005	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM			PC Approved	01/21/2020 12:00:00 AM	ADDRESS	34.1369	-118.22406	expedited per applicant request. PV1. INSTALL 18.27 KW DC PV SYSTEM WITH (58) MOUDLES, (2) INVERTERS AND (2) TESLA STORAGE BATTERIES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72890	14041-20001-24876	7014 S HOOVER ST UNIT 1	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.3KW FOR UNIT 1.ENPHASE M250 MICROINVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72891	16041-20000-26291	211 S LA BREA AVE	90036	5	138B181  1307	5513022012	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.07066	-118.34433	Plan check for energy only. Change of use from retail to restuarant. Remodel interior of tenant space, including new lighting (incl. emergency).  1,188sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72892	09041-10003-13995	267 W WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM			PC Approved	08/17/2010 12:00:00 AM	PIN	33.94684048	-118.40128468	Delta 1  Bulletin 22 -revised drawing showing routing of P-022	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72893	12041-10000-18997	22942 W VOSE ST	91307	3	183B097   423	2026006011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2012 12:00:00 AM	09/26/2012 12:00:00 AM		Permit Finaled	11/28/2012 12:00:00 AM	ADDRESS	34.19782	-118.62708	New 9.69kw rooftop photovoltaic system for an existing single family residence.  System is ungrounded.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72894	14041-10000-19810	951 N AVALON BLVD	90744	15	033B205  1182	7423004003	[Q]C2-2D-O	Harbor	Wilmington - Harbor City	Wilmington		2948.20	Electrical	Electrical	Commercial			07/23/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	33.78267	-118.26283	PLANCHECK FOR T24 ENERGY. T.I. WITHIN FIRST FLOOR OF EXISTING BUILDING. 470 SQFT, EMERGENCY LIGHTING.(((Permit pulled 11/04/2014)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72895	14041-10000-08786	970 N MONUMENT ST # 201	90272	11	129B129   823	4423017009	C1-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.04646	-118.52393	TI FOR EXISTING NAIL SALON. EXPANDING NAIL SALON INTO UNIT 203. NEW LOAD DOES NOT EXCEED 400AMPS. PLAN CHECK IS FOR ENERGY CALCULATION ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72896	17041-10000-21480	350 N FAIRFAX AVE	90036	5	138B177   171	5527037025	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	12/13/2017 12:00:00 AM	ADDRESS	34.07755	-118.36127	TItle 24 plan check.  T.I. and change of use from bakery to retail.  Subpanels to remain existing with new lighting, receptacles, and two roof mounted HP units.  Total area = 2,598       Building permit #17016-10000-17328	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72897	18041-10000-24313	4424 S WESTLAWN AVE	90066	11	108B157   859	4231015023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	07/27/2018 12:00:00 AM	ADDRESS	33.99192	-118.42597	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 2.9KVA SYSTEM - CONSISTING OF 11 MODULES WITH ENPHASE IQ6-60-2-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72898	14041-20000-12684	515 S FIGUEROA ST 4th floor	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI in a commercial highrise building restrooms on the 4th floor.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72899	16041-20000-05742	10400 N LEMONA AVE	91345	7	204B149    90	2648002047	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	07/22/2016 12:00:00 AM	ADDRESS	34.25922	-118.45849	Plan check for PV roof mounted system. System size: 5.0kW with 25 modules and 1 inverter(5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72900	15041-10001-29690	12506 W WAGNER ST	90066	9			RD1.5-1	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	33.98792	-118.42177	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72901	19041-20000-46990	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.08363	-118.32191	ADDING NEW SUBSTATION TO CENTRAL PLANT BUILDING. NEW 2.4 KV SWITCHGEAR AND CIRCUITS IN EXISTING UNDERGROUND CONDUITS. PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72902	19041-20000-25314	801 S FIGUEROA ST ste 2050	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/02/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	09/30/2019 12:00:00 AM	ADDRESS	34.04789	-118.26153	ti to an existing commercial high rise building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72903	15041-10000-18002	928 S BROADWAY BLDG B	90015	14	127-5A209 289	5139002014	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	04/10/2017 12:00:00 AM		Permit Finaled	05/29/2020 12:00:00 AM	ADDRESS	34.04154	-118.25658	PV2, ROOF MOUNTED SOLAR SYSTEM TO AN APARTMENT  BUILDING, TOTAL SIZE 232.4KW. (845) MODULES THAISUN TSG60-275M(6) SOLAREDGE SE33.3K AND (1) SOLAREDGE SE20KUS$0 permit fee per State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72904	18041-10000-13640	835 W JEFFERSON BLVD Unit #1725	90089	9	120A201     4	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	08/20/2018 12:00:00 AM	ADDRESS	34.02414	-118.28458	"FULL PLAN CHECK (POWER + ENERGY) FOR 1ST TIME TENANT (AND ALSO CHANGE OF OCCUPANCY) FROM ""RESTAURANT"" TO ""RETAIL"", FOR ABERCROMBIE & FITCH. INSTALL (1) 225A PANEL WITH ITS CIRCUITRY, TOTAL AREA: 2,736 SQ.FT"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72905	18041-20000-06705												Electrical	Electrical	1 or 2 Family Dwelling			02/23/2018 12:00:00 AM			PC Approved	11/22/2019 12:00:00 AM				VOID	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72906	17041-20001-35089	10106 W TOLUCA LAKE AVE	91602	4	165B181   355	2424031015	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2018 12:00:00 AM			PC Approved	04/25/2018 12:00:00 AM	ADDRESS	34.14844	-118.35008	4/25/2018changes to an approved set of plans.  changes to add disconnect to consolidated powerwalls.this is plan check only.    Installation of 40.5 kWh energy storage system for SFD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72907	12041-10000-25584	21031 W WARNER CENTER LANE	91367	3	174B105    24	2149017007	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM			PC Approved	10/29/2012 12:00:00 AM	ADDRESS	34.17501	-118.59119	Plan check for energy and emergency lights. Commercial T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72908	15041-20000-01493	1656 W 221ST ST	90501	15	048B193   476	7346018003	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	33.82667	-118.30839	PV1. Install roof mounted PV system sized 3.36 kW. Interconnected with main service panel. (14) SW 280 Modules(14) Enphse MicroInverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72909	18041-10001-06805	7230-7232 1/2 N OWENSMOUTH AVE	91303	3	186B105  1011	2111019007	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	Commercial			03/23/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.20198	-118.60138	Changes to an approved set of plans. All changes are clouded delta 1. Changes include adding dimmer switches, and adding area controls on the floor plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72910	12041-10000-12259	111 E UNIVERSAL HOLLYWOOD DR 11TH FL	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/29/2012 12:00:00 AM	06/15/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.13855	-118.36112	REMODELING EXISTING FLOOR HAVING OFFICES; NEW LOAD IS LESS THAN 400 AMPERES.PLAN CHK IS FOR TITLE 24 AND 1 EACH EMERGENCY LIGHT; ON 11TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72911	13041-10001-30595	12746 W JEFFERSON BLVD	90094	11	102B161  1167	4211033012		West Los Angeles				2760.00	Electrical	Electrical	Commercial			08/15/2014 12:00:00 AM			PC Approved	10/01/2014 12:00:00 AM	ADDRESS	33.97756	-118.41709	(((8/15/2014 - Changes made to approved set.  Relocation and addition of panels and lighting in new theater building.  Plans updated to reflect field comments.  All changes have been clouded on plans note that permit is to be obtained on separate application. PLAN CHECK ONLY)))Master permit work description:  9 screen Cinemark theater TI.  First time tenant from core and shell.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72912	19041-10000-17986	2191 E WHITTIER BLVD	90023	14	124-5A221 129	5183021023	R3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	03/13/2020 12:00:00 AM	ADDRESS	34.03605	-118.21915	ENERGY PLAN CHECK FOR A CHANGE OF USE FROM RETAIL TO A NEW RESTAURANT T.I (WINGSTOP).  SCOPE INCLUDES NEW LIGHTING AND EQUIPMENT WITH A TOTAL LIGHTING AREA OF 1494-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72913	13041-10000-32376	844 W 101ST ST	90044	8	091-5A199 205	6054012039	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM	02/04/2014 12:00:00 AM		Permit Closed	11/02/2015 12:00:00 AM	ADDRESS	33.94448	-118.29085	Roof mounted PV system with 3.75 KWdc on a single story house.  Transformerless inverter. Solaredge SE3800A-US. 15 modules Yingli YL250P-29b.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72914	19041-20000-42098	19545 W NORDHOFF ST Ste. 70	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM			PC Info Complete	11/07/2019 12:00:00 AM	ADDRESS	34.23566	-118.55926	FULL PLAN CHECK PER APPLICANT'S REQUEST, EXISTING 1600A SERVICE, (3) 201-600A SUB PANELS, (1) 0-200A SUB PANEL, (55) BRANCH CIRCUITS, (6) 3.1-5 KVA EQUIPMENT, (5) 5.1-20 KVA EQUIPMENT, AND TOTAL SQUARE FOOTAGE = 2936 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72915	14041-10000-32438	200 WORLD WAY # 236	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER AND ENERGY. TERMINAL 2 PICK UP STIX (236). TI. TOTAL AREA 745 SQ FT.PLAN CHECKER TO VERIFY THE FEES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72916	14041-20000-05986	6525 W SUNSET BLVD	90028	13	147A187   106	5547017038	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			03/05/2014 12:00:00 AM	07/21/2015 12:00:00 AM		Permit Finaled	12/13/2016 12:00:00 AM	ADDRESS	34.09815	-118.33187	pc for power only. new tenant space. this is rearrangement of power system for new tenant distribution. 400A equipment. this is plan check per applicatants request.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72917	14041-10000-34939	14818 W RAYMER ST Warehouse-1	91405	6	189B149   534	2210025046	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.21277	-118.45589	Title 24 plan check only.  Total area = 10,488 sq. ft.Remove HID lighting and replace with LED fixtures.Plan check covers both warehouse 1 and 2.Permit covers ONLY warehouse 1.Warehouse 2 will be included on seperate express permit 14041-10000-34940.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72918	18041-20000-14401	2100 W MARTIN LUTHER KING, JR BLVD	90008	8	114B189   370	5022017043	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress Central Area		2340.00	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	03/29/2024 12:00:00 AM	ADDRESS	34.01067	-118.31731	New 800A 208Y/120V 3ph-4w service, distribution, power, and lighting for (E) building renovation.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72919	13041-10001-15382	5601 N DE SOTO AVE 2ND FLR,-BLDG. 2	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.17126	-118.58861	CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE.  RENOVATION OF THE EXISTING PHARMACY FOR PTHTHALMOLOGY EXPANSION.  THE EXPANSION CONSISTS OF 6 EXAM ROOMS AND TWO OFFICES.  THIS SCOPE OF WORK ALSO INCLUDES THE....DECOMMISIONING OF THE EXISTING DUMBWAITER FROM 2ND FLOOR TO THE 4TH FLOOR.plan chk is for power only; TITLE 24 PLAN ON ORIGINAL APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72920	16041-20000-08950	445 S FIGUEROA ST FLR 2	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	08/30/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for Title 24 only. Project site is an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 1,275 sq. ft.Note: Building application has been generated under 16016-10000-04474	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72921	11041-20001-08185	2029 S CENTURY PARK EAST 37th Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			Corrections Issued	08/13/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	energy revision only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72922	14041-20000-03330	707 W WILSHIRE BLVD	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.04893	-118.2572	T.I. to a high rise building 39th floor, suite 3920.  Install general/emergency lighting.   Plan check for energy only.Note: Permit issued under 14041-90000-01465	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72923	10041-20001-21900	14455-14457 W ROSCOE BLVD	91402	6	192B149   361	2638022044	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			11/29/2010 12:00:00 AM			PC Approved	11/29/2010 12:00:00 AM	ADDRESS	34.22172	-118.44839	PLAN CHECK ONLY FOR T24 ENERGY FOR LIGHTING. EXISTING PERMIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72924	18041-10000-02341	1125 N NAPOLI DR	90272	11	129B133   263	4408004016	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2628.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM			Corrections Issued	02/22/2018 12:00:00 AM	ADDRESS	34.04828	-118.50432	PV1, New roof mounted solar system in a SFD with an energy storage system. (2) Inverters, 7.6KWAC and 5.2KWAC, (39) module, (1) load center, (3) AC Tesla Batteries.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72925	14041-10000-05325	1200 W 7TH ST 3RD FLR	90017	1	130-5A207 213	5143006013	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	04/14/2014 12:00:00 AM		Permit Finaled	07/25/2014 12:00:00 AM	ADDRESS	34.05136	-118.26616	PC FOR POWER AND ENERGY. highrise. 14016-10000-03240 building description: TENANT IMPROVEMENT WORK ON ENTIRE 3RD FLOOR (40,719 S.F.).  NEW WOMEN'S RESTROOM. NEW WALLS, POWER, LIGHTING, CEILING, AND FINISHES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72926	15041-20001-18865	10100 W SANTA MONICA BLVD 7th & 8th-Floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2015 12:00:00 AM			PC Approved	08/26/2015 12:00:00 AM	ADDRESS	34.06191	-118.41691	08/26/2015 Changes to an approved set of plans. Changes include the reduction of the work area from the entire 8th floor to approximately half of the 8th floor. All changes have been reflected onto the Title 24 Compliance Forms. All changes have been clouded and marked as Delta 3.*****Previous Work Description*****Plan check for Title 24 only. Project site is the 7th and 8th floor of an existing high-rise commercial building. Project scope is a tenant improvement. Total indoor lighting area = 15,748 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72927	19041-20000-44910	1320 N LAKE SHORE AVE	90026	13	141A209   702	5419031013	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1974.20	Electrical	Electrical	Commercial			11/01/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.07876	-118.2599	Plan check for Title 24 energy only, new lighting. Total area: 2350 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72928	10041-10001-20542	3525 E EMERY ST	90023	14	117A225   300	5192008013	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM			PC Approved	02/10/2011 12:00:00 AM	ADDRESS	34.01427	-118.20201	Change the approved plan. Change the T24 & Energy Calc. EPC is for Energy & Emergency lights. ( The privious plan was design by different Engineer)    ((((((((((((((TI IN AN EXISTING COMMERCIAL AREA (WAREHOUSE & OFFICES) DUE TO FIRE DAMAGE. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72929	12041-10001-29808	17401 W VENTURA BLVD A-39	91316	5	171B129   383	2257016059	(Q)C4-1VL, [Q]P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.16136	-118.51189	changes to approved set of plans. changed the front and corridor. changed lights to LED. TI FROM RETAIL TO CHIROPRACTOR. STE A-39. 1ST FLOOR OF MALL. MALL DOES NOT HAVE GENERATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72930	14041-10000-13476	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/20/2014 12:00:00 AM			PC Approved	05/20/2014 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLAN CHECK FOR ENERGY ONLY FOR ELECTRICAL ROOM LIGHTING AND STORAGE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72931	16041-20001-16804	6510 N GLORIA AVE	91406	6	180B141   590	2233013014	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM			PC Approved	08/17/2016 12:00:00 AM	ADDRESS	34.18898	-118.47914	8.17.2016 - Standard plan was checked and approved in error. Recheck system using contractor designed set of plans.  New system is in addition to existing 6kW ungrounded system. Total system size is 11kW.====Plan check for PV roof mounted system. System size: 5.0kW and  19 modules and 1 inverter (5.0kW). Standard plan is being use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72932	13041-10000-06027	1333 1/2 N WATERLOO ST	90026	13	141A207   127	5424023005	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1956.00	Electrical	Electrical	Apartment			03/07/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	07/30/2013 12:00:00 AM	ADDRESS	34.08138	-118.26534	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. PART OF MULTI FAMILY COMPLEX. THIS APPLICATION IS IN CONJUNCTION WITH TWO OTHERS. TOTAL SYSTEM SIZE FOR THIS APPLICATION IS 1.68 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72933	14041-10000-18269	3600 W WILSHIRE BLVD Suite 100H	90010	10	132B193    56	5093020001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2124.10	Electrical	Electrical	Commercial			07/08/2014 12:00:00 AM			Corrections Issued	07/08/2014 12:00:00 AM	ADDRESS	34.06156	-118.30335	TItle 24 part 6 plan check only.  Total area = 1,210 sq. ft.T.I. to existing highrise commercial space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72934	15041-20000-12103	444 S FLOWER ST SUITE 500	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NEWLY CONNECTED LOAD < 400 AMPS. 5TH FLOOR SUITE 500. 10159 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72935	17041-10000-07757	3139 W SAN FERNANDO ROAD	90065	13	154-5A213 198	5458007009	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			03/10/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Issued	03/10/2017 12:00:00 AM	ADDRESS	34.11595	-118.24672	PC for energy only, outdoor. Removing and replacing HID fixtures with new LED ones. Area: 2,000.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72936	16041-20000-02884	7900 N BALBOA BLVD BLDG 'J'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/26/2016 12:00:00 AM	02/04/2016 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.21347	-118.50092	Plan check for power and energy Aircraft Hangar Building 'J' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' J' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72937	14041-10000-10489	1651 N ALAMEDA ST	90744	15	036B213     7	7426028005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			04/22/2014 12:00:00 AM			PC Info Complete	05/27/2014 12:00:00 AM	PIN	33.79703283	-118.23948786	PLAN CHECK FOR POWER AND HAZARDOUS AREA. NEW TRANSFORMER AND DESALTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72938	19041-30000-03784	11150 W OLYMPIC BLVD 10th Floor	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.03956	-118.43857	Plan check for Title 24 only. Project site is common area corridors and restrooms in an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,870 sq. ft.Note: Building permit has been issued under 19016-30000-00329	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72939	11041-20000-27448	14222 W OXNARD ST	91401	2	177B153   886	2245018008	CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	10/22/2012 12:00:00 AM	ADDRESS	34.17926	-118.44294	New 7 KW pv system mounted on the roof of a repair garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72940	19041-10000-40586	10651 N SAN FERNANDO ROAD	91331	7	207B157   724	2620001009	CM-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			10/07/2019 12:00:00 AM	05/15/2020 12:00:00 AM		Permit Finaled	07/15/2022 12:00:00 AM	ADDRESS	34.26347	-118.41962	FULL PLAN CHECK FOR NEW 1-STORY COMMERCIAL SHELL BUILDING RETAIL (32'X86') LIGHT MANUFACTURING (55'X99'). SERVICE SIZE 800A, 120/240V, 3PH, 4 WIRE.  AREA OF SCOPE 7772SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72941	16041-20001-36504	7052 N MAMMOTH AVE	91405	2	183B157   260	2216026002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2016 12:00:00 AM			PC Approved	11/04/2016 12:00:00 AM	ADDRESS	34.19912	-118.43228	Expedited plan check fee as per requested from customer. PV1. Install (11,180kW) PV roof mounted system with microinverters (52) modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72942	17041-10000-04440	12775 W BLUFF CREEK DR	90094	11	102B161  1270	4211037026	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	33.97448	-118.41663	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 4 STORY THREE UNIT CONDO APARTMENT BUILDING. SCOPE INCLUDES 59 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72943	15041-10000-03752	11909 W LAURELWOOD DR	91604	2	162B169   280	2369016020	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			02/06/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.14208	-118.39166	New fire alarm system for a 5-Unit town home with (1) fire alarm panel, and (35) devices)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72944	13041-10000-30171	11362 W CHENAULT ST	90049	11	132B145    14	4365010024	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	11/21/2013 12:00:00 AM	ADDRESS	34.06219	-118.45919	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 5000A-US. 18 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72945	10041-10000-16801	3951-4015 N RESEDA BLVD	91356	3	162B121    10	2177032021	A1-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01, 1398.02	Electrical	Electrical	Public Safety Only			08/25/2010 12:00:00 AM	08/25/2010 12:00:00 AM		Permit Finaled	02/17/2011 12:00:00 AM	ADDRESS	34.14244	-118.54161	fire alrm central station monitoring within the Braemar Country Club	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72946	15041-20000-11505	16901 W NAPA ST	91343	12	195B133   508	2689018032	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Apartment			04/14/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.22679	-118.50046	Plan check for PV 10 kWac system roof mouned with 1 inverter (CANADIAN SOLAR CS6X-305SSP), 36 modules (canadian solar cs6x-305sp) and 1 combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72947	19041-10000-53139	1000 N EDINBURGH AVE	90046	5	144B177   275	5529014046	R4-1	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM			Reviewed by Supervisor	02/11/2020 12:00:00 AM	ADDRESS	34.08892	-118.36365	ELECTRICAL PLAN CHECK FOR NEW APARTMENT RESIDENTIAL BLDG. T24 AND ENERGY SCOPE INCLUDES 9757SF; (22) PANELS, (316) CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72948	10041-10000-05542	208 E 8TH ST	90014	14	127-5A211 318	5145013022	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/26/2010 12:00:00 AM			PC Approved	03/26/2010 12:00:00 AM	ADDRESS	34.04149	-118.25217	Energy and Emerg lighting  plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72949	16041-10000-38115	21425 W VANOWEN ST	91303	3	183B105   951	2138011023	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/19/2017 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.19399	-118.59858	Full PC for new 6 story with 1 level of basement. 174 unit apartment. All new equipment. (2) New main switchboards rated at 5000A 120/208V 3 phase 4wire AND 2000Amps 120/208V 3phase 4wire. 17 typical units. Total sqft = 126,537.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72950	17041-10000-01478	832 S OLIVE ST	90014	14	127-5A209  95	5144018026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.04427	-118.25743	PC FOR POWER AND ENERGY. CHANGE OF USE FROM RETAIL TO RESTAURANT AND MICROBREWERY. NEW OUTDOOR DINING.  OCCUPANCY LOAD IS 152 PER ARCHITECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72951	17041-10000-35091	11911 W BRANFORD ST	91352	7	204B165    72	2528007014	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.2567	-118.39186	PC for power and energy for new shop, fuel bay buildings and dock building expansion. Installing new 120/208V 800A service switchboard, ten new panels, new branch circuit and equipment.Total area of 38797sqft. Plan checker to verify that service is being reconnected to new service equipment.17041-10000-03245RENOVATION OF FEDEX FREIGHT SERVICE CENTER: 20 DOOR DOCK ADDITION; NEW OFFICE ADDITION TO SERVICE CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72952	12041-10000-04023	10230 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			PC Approved	02/22/2012 12:00:00 AM	ADDRESS	34.25635	-118.57963	TITLE 24 ENERGY ONLY WITH EMERGENCY LIGHTING ON A SINGLE STORY RETAIL STORE. TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72953	10041-20000-05659	18225 W SHERMAN WAY	91335	3	186B125   889	2119028005	[Q]C2-1L-CDO, [Q]P-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.20134	-118.53046	REMODEL STORE FRONT, 2 NEW ADA RESTROOMS, NEW BREAKROOM, AND 1-NEW OFFICE energy, egress lighting	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72954	17041-10000-20278	755 N LA CIENEGA BLVD	90069	5	141B173   242	4337002075	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	08/17/2017 12:00:00 AM	ADDRESS	34.08514	-118.37686	RESTAURANT TI. PC FOR POWER AND ENERGY. A OCCUPANCY GREATER THAN 100. ONLY UPGRADING SOME LIGHTING AND COUPLE OF CIRCUITS. MOST REMAIN EXISTING.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
72955	14041-10000-26383	442 S VIRGIL AVE	90020	13	135A201    54	5077001030		Central				2111.20	Electrical	Electrical	Public Safety Only			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.06539	-118.28684	NEW FIRE WARNING SYSTEM FOR 74-UNITS APT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72956	14041-20000-09007	7523 N NEWCASTLE AVE	91335	3	186B125   362	2120021028	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.20726	-118.52527	Roof mounted PV system with Optimizer, system size 5KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72957	13041-10000-27742	12121 W WILSHIRE BLVD	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM			PC Approved	10/07/2013 12:00:00 AM	PIN	34.04391963	-118.46825257	permit to be pulled at EPC counter only. PC FOR ENERGY. TI TO (E) OFFICE IN HIRISE #1260. (changes made on plans show one light in corridor modified to be emergency light fixture on 10/7/2013 - mt)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72958	14041-20000-17202	224 E 73RD ST	90003	9	102B205  1039	6022010012	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2396.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	33.97369	-118.27097	PV1.  Install 4.3 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72959	18041-20001-40443	5005 N SANLO PL	91364	3	168B113    25	2166038013	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	01/03/2019 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.16056	-118.57508	1/3/2019: Supplemental permit to correct work description: Installation of 12.03 kW DC / 11.23 kW AC CEC PV system.  (37) modules with microinverters.  11/13/2018: Changes to an approved set of plans. PV system no longer has battery back-up and now only consists of (37) modules, (37) micro-inverters, and (1) load center. System size has remained the same. Remaining distribution equipment has been relocated.*****Previous Work Description*****Plan check for PV roof mounted system and energy storage system, PV system size: 11.23KW AC CEC with 37 PV Modules and 37 Microinverters, Tesla Power Wall 2.0 13.5KWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72960	16041-10000-33203	9200 N SHIRLEY AVE 2nd FL-Macy's	91324	12	198B117   167	2761037022	C4-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/28/2016 12:00:00 AM		Issued	09/28/2016 12:00:00 AM	ADDRESS	34.23787	-118.55774	PC for T24 only for change in occupancy in Macy's store into an optometrist office. Installing new lights and receptacles and 100 A panel. **TI to existing department store to create new shop.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72961	16041-20001-31691	15954 W VOSE ST	91406	6	183B141   342	2224007042	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.19824	-118.48106	EXPEDITE PER APPLIACNT PV1INSTALL ROOF MOUNTED  PV SYSTEM (ACM) INTERCONNECTED WITH MSP.  SYSTEM SIZE 14.7KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72962	19041-10000-08233	4545 N HOMER ST	90031	1	147A225    37	5303025900	[Q]OS-1XLD	East Los Angeles	Northeast Los Angeles	Arroyo Seco, Historic Highland Park	YES	1993.00	Electrical	Electrical	Commercial			03/07/2019 12:00:00 AM	03/08/2019 12:00:00 AM		Permit Finaled	07/09/2019 12:00:00 AM	ADDRESS	34.09533	-118.20334	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (INDOOR)- T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72963	15041-20000-04746	901 S ABBOT KINNEY BLVD	90291	11	109-5A143 374	4286012040	C2-1-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	02/18/2015 12:00:00 AM		Permit Expired	03/14/2017 12:00:00 AM	ADDRESS	33.9927	-118.47312	TI TO AN EXISTING COMMERCIAL BUILDING (OFFICES).  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 3726.  SCOPE OF WORK TO BE PERFORMED IN FIST AND SECOND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72964	13041-10001-15126	20000 S WESTERN AVE	90501	15	057B193     4	7351003012	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/29/2013 12:00:00 AM	10/29/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	ADDRESS	33.85008	-118.30908	Delta-3 revisions to approved set.  One additional panel and associated receptacle loads.  (((This is a one story shell to be come offices, warehouse, light industrial. Power, lighting, hvac, title 24 and emergency lighting.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72965	19041-10000-20552	953 N SYCAMORE AVE	90038	4	144B181   641	5531015010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	PLAN CHECK FOR POWER FOR NEW 800 AMP 480/277v 3ph DISTRIBUTIONBOARD FOR TENANT IMPROVEMENT OF 7TH FLOOR OFFICE SPACE FEEDING FROM EXISTING DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72966	16041-10000-08982	9938 N DEBRA AVE	91343	12	201B137    30	2678015015	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.25138	-118.49043	PV1 rooftop solar installation 12kW system    (39) SPR327NE-WHT-D     (1) SB7000TL-US   (1) SB5000TL-US   (1) 125A load center	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72967	11041-10000-16498	320 E 111TH ST	90061	15	088-5A205 292	6073019900	PF-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Public Safety Only			08/22/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	33.93471	-118.26871	New fire warning system for the LOCKE MULTI SERVICE & CHILD DEVELOPMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72968	13041-20000-24675	1214 N TURQUESA LANE PV-1	90272	11	132B121   326	4420024037	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	10/10/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.05691	-118.54825	PV-1. 26.6kW AC (two 11.4kW inverters and one 3.7kW inverter). Large inverters are grounded DC and smaller transformer is transformerless.(((SOLAR PERMIT FEE CAP IN EFFECT. FINAL FEE PERIOD IS CORRECT, NO AMOUNT DUE))))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72969	11041-10000-19998	1328 S SANTA FE AVE	90021	14	121-5A217 172	5168031005	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/20/2011 12:00:00 AM			PC Approved	10/31/2011 12:00:00 AM	ADDRESS	34.02781	-118.22976	T.I. TO AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK ONLY FOR ENERGY WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72970	13041-10000-08436	1146 S ABBOT KINNEY BLVD	90291	11	108B145  1194	4238003020	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			04/02/2013 12:00:00 AM			PC Approved	04/02/2013 12:00:00 AM	ADDRESS	33.99132	-118.46918	"RENOVATION IN EXISTING RESTAURANT "" BELLY UP"" -NEW PANELBOARD,CKTS AND LUMINAIRESPLAN CHK IS FOR TITLE 24 ONLY"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72971	16041-10000-22842	649 S OLIVE ST	90014	14	129A209   151	5144003904	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2016 12:00:00 AM	09/16/2016 12:00:00 AM		Permit Finaled	11/03/2023 12:00:00 AM	ADDRESS	34.047	-118.25536	Full plan check. Interior remodeling. Change of use from office to hotel of an existing 13 story building. 3 new services. (2) 1000 Amp services 277/480 3phase 4w and  (1) 1200 Amp service 120/208 3phase 4 wire.  All new equipment. Total sqft =59233.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72972	14041-10000-17524	2049 S CENTURY PARK EAST 10TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.05903	-118.41293	TITLE 24 HIGH RISE BUILDING. AREA = 11798	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72973	18041-10001-29912	14640 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.22128	-118.45128	This is plan check only to replace a lost original approved plan. Permit has been issued under 18041-10000-29912<<PLAN CHECK FOR TITLE 24 ONLY - TENANT IMPROVEMENT FOR NEW STARBUCKS COFFEE TO INCLUDE NEW PARTITION WALLS, LIGHTING FIXTURES, CASE WORK, MEP. TOTAL AFFECTED AREA = 1847 SF.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72974	11041-10000-22842	937-939 N SUN MUN WAY 201-301	90012	1	135A215   177	5414011015	C2-2	Central	Central City North	Historic Cultural	YES	2071.00	Electrical	Electrical	Commercial			10/25/2011 12:00:00 AM	10/25/2011 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.06493	-118.23753	Install fire alarm system in EXISTING 3-STORY building with TO RETAIL ON THE 1ST FLOOR AND JOINT-LIVING AND WORK QUARTER ON 2ND AND 3RD FLOOR WITH 1/3 RESSIDENTIAL AND 2/3 COMMERCIAL SPACE. NO CHANGE IN PARKING REQUIREMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72975	15041-10000-40845	11675 N GLENOAKS BLVD	91331	7	213B157   218	2524022003	C2-1, P-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM	12/04/2015 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.2823	-118.42116	NEW FIRE ALARM SYSTEM TO A COMMERCIAL BUILDING. (51) FIRE ALARM DEVICES AND (1) FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72976	14041-10000-19125	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/16/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	08/21/2014 12:00:00 AM	ADDRESS	34.24253	-118.57768	NEW 1-STORY CONTAINMENT BLDG ACCESSORY USE TO (E) MFG  BLDGPLAN CHK IS FOR TITLE 24 ONLY14010-20000-00807	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72977	13041-10001-32263	6062 N SHADYGLADE AVE	91606	2	177B165   510	2333015001	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.1812	-118.40182	Expedited RSES plan check perc applicant request.(((PV1, Install 4.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE3800A-US. 17 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72978	18041-10001-03052	12701 W VAN NUYS BLVD Ste M	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	34.27621	-118.41056	NO PLAN CHECK FEES DUE TO DEPARTMENT ERROR - ADDRESS MODIFICATIONREMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. PLAN CHECK T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72979	12041-10000-27531	17759 W CALLE DE PALERMO	90272	11	141B113    14	4431020003	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.07938	-118.57298	ROOF MOUNTED PV1 SOLAR INSTALLATION AND INTERCONNECTION TO MAIN SEVICE PANEL. STANDARD PLAN USING FRONIUS INVERTER AND SUNIVA OPTIMUS MODULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72980	13041-20000-18405	6600 W SUNSET BLVD	90028	13	147A185    65	5547024011	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/12/2013 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.09782	-118.33334	NEW CONSTRUCTION/EXPANSION OF EXISTING MIX USE/RETAIL AND OFFICE SPACE. PC FOR POWER AND ENERGY. NEW 1600A SERVICE. EXISTING BUILING TO CONNECT TO NEW CONSTRUCTION. NON HAZARDOUS AREA	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72981	16041-20000-21782	13451 W GRIDLEY ST	91340	7	222B157   378	2513008035	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	07/23/2016 12:00:00 AM	ADDRESS	34.30392	-118.4267	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72982	19041-10000-04028	2966 S KELTON AVE	90064	5	123B157  1161	4254003034	R3-1	West Los Angeles	West Los Angeles	Westside		2717.01	Electrical	Electrical	Apartment			02/01/2019 12:00:00 AM			Reviewed by Supervisor	03/11/2019 12:00:00 AM	ADDRESS	34.0301	-118.42277	FULL PLAN CHECK FOR NEW 6 STORIES 17 UNIT APARTMENT BUILDING. SCOPE OF WORK INCLUDES (1) 1000A SERVICE AND PANEL, (1) 600A PANEL, (1) 500A PANEL, (2) 250A PANELS, (10) 100A PANELS, (8) 125A PANELS, (1) 25 HP ELEVATOR MOTOR, AND T24 TOTAL SQUARE FOOTAGE = 10,241 SFBLDG PERMIT #19010-10000-00480	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72983	18041-20000-43761	20825 W SPRUCE CIR #60	91326	12	219B109   359	2761001***	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.29531	-118.58765	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72984	16041-20001-40109	18710 W VINTAGE ST	91324	12	201B121    65	2729019018	RS-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2016 12:00:00 AM			PC Approved	12/05/2016 12:00:00 AM	ADDRESS	34.25083	-118.54097	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of roof-mounted solar PV system on SFD. Interconnect with a 200A MSP.Derating main to 175A. 10kW ungrounded system. (26) 290W pv modules. Each module has a 300W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72985	10041-10000-02745	11847 W GORHAM AVE	90049	11	129B145   171	4265018001	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Public Safety Only			02/17/2010 12:00:00 AM	03/24/2010 12:00:00 AM		Permit Closed	08/29/2014 12:00:00 AM	ADDRESS	34.05206	-118.46883	Plan check for installation of  new fire alarm panel and initiating devices to exsiting fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72986	17041-10000-07176	9355 N RESEDA BLVD	91324	12	198B125   167	2763004001	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			03/06/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.24065	-118.53629	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3963 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72987	15041-10000-19685	4105 W 60TH ST	90043	8	105B181   519	4003005023	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM			Corrections Issued	06/23/2015 12:00:00 AM	ADDRESS	33.98542	-118.34661	PV1 INSTALL 4 KW DC SOLAR ARRAY ON A  SINGLE FAMILY HOUSE, (16) MODULES;(1) INVERTER:	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72988	17041-10000-42638	13715 W VANOWEN ST	91405	2	183B157   940	2216025059	[Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	Commercial			11/28/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.19408	-118.43187	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72989	14041-10000-08129	13792 W SUNBURST ST	91331	6	198B153   803	2642025011	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/26/2014 12:00:00 AM		Permit Expired	04/20/2016 12:00:00 AM	ADDRESS	34.23749	-118.43376	PV1. ROOFMOUNTED SOLAR SYSTEM. TRANSFORMERLESS STANDARD PLAN. SYSTEM SIZE: 5.5 KW.(22) CANADIAN SOLAR #CS6P-250PX(1) POWER-ONE # AURORA PVI-5000	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72990	13041-10000-27672	6430 W SUNSET BLVD SUITE 1450	90028	13	147A187   153	5546014047	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM			PC Approved	10/10/2013 12:00:00 AM	ADDRESS	34.09782	-118.32979	TI for a highrise office building - suite 1450.  Title 24 plan check only for lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72991	16041-10000-42907	1701 N KILBOURN ST	90065	1	148-5A217 149	5455006043	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.03	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.10187	-118.22969	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 4.8KWac.(15)AC MODULES-SPR-E20-327-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72992	18041-10000-08441	1722 W 51ST PL	90062	8	108B193    42	5003005007	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	07/12/2018 12:00:00 AM	ADDRESS	33.99587	-118.30763	PC FOR  A NEW ROOFTOP SOLAR SYSTEM AND ENERGY STORAGE SYSTEM (TESLA POWERWALL) IN A SINGLE FAMILY DWELLING. , CONISIT OF 6 MODULES(#SC325) AND A CENTRAL INVERTER (DELTA SOLIVIA 3.8) . SYSTEM SIZE IS 3.8KWac AND 1.95KWdc.SCOPE INCLUDES NEW LOAD CENTER (200A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72993	19041-10000-05298	6020 W 83RD PL	90045	11	096B169    53	4107026022	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2019 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	33.96279	-118.39001	Permit fee is $0.00 due to AB1414.Plan check for a roofmounted TILE PV system with (3) strings, (2) inverters, and (2) power supplies interconnecting through the main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
72994	15041-10000-04575	8712 S METTLER ST	90003	9	096A207    13	6041019017	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	33.95883	-118.26644	PC FOR ENERGY T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 8128 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
72995	12041-10000-07695	500 S VIRGIL AVE 4TH FLOOR	90020	4	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	TI IN A MEDICAL OFFICE BUILDING ON THE 4TH FLOOR. PLAN CHECK FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72996	12041-10001-18057	630 W HARRY BRIDGES BLVD Main Bldg	90744	15	027B205   442	7440006910	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Closed	02/07/2014 12:00:00 AM	ADDRESS	33.77068	-118.26868	NEW FIRE ALARM SYSTEM FOR NEW ADMINISTRATION BUILDING.  MAIN BUILDING IS SUBMITTED SEPARATELY.  Photovoltaic system is on supplemental application.  Building is in a Methane Zone.  Methane detection system is on a separate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72997	14041-10001-06676	12855 W RUNWAY ROAD block 1	90094	11	102B157   395	4211033054	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Public Safety Only			08/17/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	33.97556	-118.41956	Revision to an approved set with adding # of devices less than 10.<<<New fire alarm system. block 1. playa vista.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
72998	16041-20000-08465	19167 W ALLANDALE DR	91356	3	162B121    96	2177042020	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2016 12:00:00 AM	03/10/2016 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	34.13808	-118.55086	Plan check for a PV1 roof-mounted PV system. System size is 9.1 kWac and consists of (32) modules, (32) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
72999	16041-20003-26870	23397 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			03/03/2017 12:00:00 AM			PC Approved	03/03/2017 12:00:00 AM	ADDRESS	34.15981	-118.6342	03/03/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 7. Changes have been made to the single line diagram, the lighting floor plan, and the power floor plan.*****Previous Work Description*****Changes to an approved set of plans. All changes are made under delta 6. Changes include relocating/removing emergency lights, adding bug eyes, and revising emergency photometrics.FULL PC FOR POWER AND ENERGY FOR (E) RESTAURANT WITH OUTDOOR DINING AREA. SCOPE INCLUDES NEW LIGHTS AND NEW RECEPTECLES. TOTAL AFFECTED AREA 4497 SQ FT.T-24, PLAN CHECK FOR ENERGY ONLY. TENANT IMPROVEMENTS OF (E) RESTAURANT WITH OUTDOOR DINING AREA. SCOPE INCLUDES NEW LIGHTS AND NEW RECEPTECLES. TOTAL EFFECTED AREA 4497 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73000	15041-10001-25634	731 S BROADWAY	90014	14	127-5A209  68	5144014032	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.04456	-118.25423	Delta 6 changes to permitted set of plans: lighting plans ans added a couple receptaclesAll changes are clouded and identified as Delta 6((((((((((((PC for power and energy. Scope includes new 800A 120/240V 3ph-4w service and distribution system for (E) 4-story commercial building. Total affected area is 19295 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73001	17041-20000-46513	24444 W EILAT ST	91367	2	177B089   801	2032023015	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM	01/08/2018 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.17781	-118.65741	INSTALLATION OF ENERGY STORAGE SYSTEM. SYSTEM SIZE: 10KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73002	16041-30000-17315	4108 W SANTO TOMAS DR	90008	8	114B181   187	5031003004	[Q]RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.00981	-118.34469	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01102	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73003	13041-10000-21030	11601 W WILSHIRE BLVD 14TH FLOOR-15TH FLOOR	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	TENANT IMPROVEMENT,TITLE 24 FOR HIGH-RISE BUILDING. WORK IS PERFORMED ON THE 14TH & 15TH FLOOR. TOTAL OF 28000 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73004	16041-20000-30619	21650 W OXNARD ST Suite 2375	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for energy only. TI to existing commercial office in high rise building. New lights (incl. emergency) and receptacles. 2,016sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73005	13041-10001-02275	4550 W PICO BLVD CHIPOTLE	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	PLAN CHECK PER APPLICANTS REQUESTL PLAN CHECK ONLY, PERMIT IS UNDER 13041-10000-02275. PULL ELECTRICAL FEEDERS FOR TRANSFORMER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73006	18041-10000-14436	4755 S ALLA ROAD	90292	11	105B157   549	4212007006	P-1, [Q]MR1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM			PC Approved	05/19/2020 12:00:00 AM	ADDRESS	33.9835	-118.43032	FULL PC FOR POWER AND ENERGY. CHANGE OF USE FROM OFFICE/WAREHOUSE TO AUTO SALES/SERVICE/OFFICE WAREHOUSE. SCOPE INCLUDES ADDING NEW 1200A 277/480 3 PHASE 4WIRE DISTRIBUTION BOARDS, NEW PANELS,  NEW SUPER EV CHARGERS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 96843 SQ. FT. B#18016-10000-11892	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73007	17041-10001-30454	601 S ARDMORE AVE 100	90005	10	135B193   875	5503025014	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM			Corrections Issued	09/21/2017 12:00:00 AM	ADDRESS	34.06322	-118.30183	PC FOR CHANGES TO APPROVED SET UNDER  DELTA 2. SCOPE INCLUDES CHANGES TO LIGHTS FIXUTRES AND SERIES RATING COMBANATION. THIS IS PLAN CHECK ONLY!!PERMIT UNDER ORIGINAL  PC FOR POWER AND ENERGY. NEW LIGHTING IN DINING AREAS AND NEW INDUCTION COOKERS FOR SHABU STATIONS. ALTERATION IN ASSEMBLY OCCUPANCY GREATER THAN 100. TOTAL AFFECTED AREA IS 3510 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73008	16041-10000-23507	3981 S MOORE ST	90066	11	111B153  1276	4236021026	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.02	Electrical	Electrical	Commercial			07/07/2016 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	33.99624	-118.4379	Plan check for energy and powe.  new 7-unit apartment with a subterranean garage.  Service size is rated at 6oo amps. Installing new lighting and power. 3 type units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73009	12041-20000-23181	9870 N SAN FERNANDO ROAD	91331	7	201B165    77	2537015042	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			05/18/2012 12:00:00 AM			PC Approved	07/19/2012 12:00:00 AM	ADDRESS	34.25001	-118.40419	change all feeders from copper to aluminum	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73010	18041-20000-48718	1647 S HI POINT ST	90035	10	129B173  1321	5068015025	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	12/31/2018 12:00:00 AM	ADDRESS	34.0466	-118.37023	Plan check for PV roof mounted system, systrem size: 9.57kW DC, 8.134kW AC with 29 PV Modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73011	13041-10000-12569	3119 N DONA ELENA PL	91604	2	156B169   146	2381025009	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.1268	-118.38362	PV1 18.13KW NONSTD ROOFMOUNT. XFMRLESS. solaredge se6000A-us (1) and se5000A-US (2x) . also trina solar TSM-245PC05 (74 modules)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73012	15041-20000-17102	12180 W MILLENNIUM 4TH FLR	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	PLANCHECK FOR T24 ENERGY. INTERIOR TENANT IMPROVEMENT TO (E) OFFICE.  4TH FLOOR. 7498 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73013	19041-10000-03203	10371 W NORTHVALE ROAD	90064	5	123B161   667	4318036016	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	34.03284	-118.41378	PC for Energy storage system added to an existing solar system. Energy storage system is a Tesla power wall.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73014	13041-10000-25627	8506 S OSAGE AVE	90045	11	096B173    97	4127024025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	01/21/2015 12:00:00 AM	ADDRESS	33.96089	-118.37861	permit is issued under the original application excluded the first floor under the airline stores that has to be checked aseperately.TITLE 24 PLAN CHECK ONLY. LEGALIZE PREVIOUSLY CONSTRUCKTED MEZZANINE & PLACK BRIDGE MEZZ. 2STORY . WORK IS ON BOTH FLOORS. 12342 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73015	17041-10000-24066	19751 W MARIPOSA CREEK WAY	91326	12	213B113   164	2701028038	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.28213	-118.56623	PC for new (2)Tesla Powerwall2 (14KW) connecting to existing house panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73016	14041-10000-00380	1039 S WALL ST	90015	14	124-5A209  40	5145019019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	01/21/2014 12:00:00 AM	ADDRESS	34.03682	-118.25411	T24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. PROJECTED AREA IN LIGHTING WORK IS APPROX. 564 SQ FT. TOTAL OF (2) UNITS WILL BE REPLACED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73017	19041-20000-20493	1200 S GRAND AVE	90015	14	126A207   131	5139023039	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.03989	-118.26331	FULL POWER AND ENERGY PLAN CHECK FOR FIRST TIME TENANT OF A RETAIL SPACE CONVERTED INTO A GYMSPACE, IN A EXISTING MIXED USE 7-STORY APT BLDG, TOTAL SQUARE FOOTAGE = 2400SFCHANGE OF USE BULDING PERMIT UNDER #18016-20000-33546	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73018	19041-20001-06817	9377 S LINCOLN BLVD	90045	11	096B161   838	4119039004	[Q]C4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	Apartment			02/26/2019 12:00:00 AM			PC Approved	04/24/2019 12:00:00 AM	ADDRESS	33.95496	-118.41468	Expedited plan check fee.PV2.  Install 55.08 kW DC / 49.43 kW AC roof mounted grid tied PV system.  (153) modules with 20 and 30 kW rated string inverters.System 4 of 4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73019	13041-10000-04625	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010	[Q]M3-1	Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM	08/12/2013 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	PLAN CHECK FOR INSTALLATION OF CABLE TRAY, 4.61KV/480V TRANSFORMER, AND 2000A SWITCHBOARD TO SUPPLY EXISTING FIRE DAMAGED ADMIN BUILDING. ADMIN BUILDING ELECTRICAL PLAN CHECK APPROVED UNDER #12041-10000-30438. INSTALLTION LOCATED IN HAZARDOUS METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73020	17041-20000-32832	304 S BROADWAY 5th Floor	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	12/20/2017 12:00:00 AM		Permit Finaled	01/18/2019 12:00:00 AM	ADDRESS	34.05076	-118.248	Tenant improvement to (E) commercial office space.  Plan check for energy - 9,373 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73021	14041-10000-31982	409 S ST ANDREWS PL	90020	4	135B193   470	5504030002	R4-1	Central	Wilshire	Greater Wilshire		2117.03	Electrical	Electrical	Apartment			11/18/2014 12:00:00 AM			Reviewed by Supervisor	12/11/2014 12:00:00 AM	ADDRESS	34.06675	-118.31188	Plan check for power and title 24.  New 15 unit 4 story apartment building.  6 typical units.  New 1000A service with 7,205 sq. ft. of common area.  Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73022	17041-10000-18463	11250 W SANTA MONICA BLVD 1-78	90025	11	129B149   438	4261008022	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	06/14/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.04661	-118.44736	Installation of new fire alarm system in existing hotel building with 4 floors above 2 parking levels.  Total system size = 292 devices + 3 power supplies and 1 FACP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73023	17041-10000-43701	1501 W FRANCISCO ST	90501	15	057B193    26	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/05/2017 12:00:00 AM	12/05/2017 12:00:00 AM		Permit Finaled	12/12/2017 12:00:00 AM	ADDRESS	33.8498	-118.30433	changing fire alarm panel. all devices are existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73024	14041-10000-30856	737 S BROADWAY	90014	14	127-5A209  77	5144014030	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/06/2014 12:00:00 AM		Permit Expired	12/11/2023 12:00:00 AM	ADDRESS	34.04443	-118.25434	Installation of new fire alarm system for existing commercial highrise building.  128 total devices + 1 control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73025	16041-10000-31375	10403 W PENROSE ST	91352	7	195B177   204	2544030020	RA-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.2323	-118.35778	Plan check for PV roof mounted system. System size: 6.7kW with 24 modules and 24 microinverters.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73026	10041-20000-20754	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM			PC Info Complete	10/19/2010 12:00:00 AM	ADDRESS	34.10137	-118.34182	"T.I. in the existing high rise building of ground floor of Public Kitchen and Bar.  Install general/emergency lighting.  Plan check for energy only.""COMPLY WITH DEPARTMENT ORDER effective date11/13/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73027	14041-20000-24933	21550 W OXNARD ST 2nd floor-bathroom	91367	3	177B105    85	2146006030	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/11/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for energy only. New lighting in a bathroom on the 2nd floor of an existing high rise office building. 436sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73028	10041-20000-00181	1714 N MCCADDEN PL	90028	13	148-5A185  86	5547010011	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			01/06/2010 12:00:00 AM			Corrections Issued	01/25/2010 12:00:00 AM	ADDRESS	34.1021	-118.3373	"Revisions dated up to ""01.05.2010"" on previously approved plans with PCIS # 08041-20000-03082 (NEW 4 STORY -218 UNIT APARTMENT BUILDING OVER SUBTERRANEAN PARKING.) Revised single line diagram, lighting in units, unit panel locations, elevator control rooms, and pool & spa room."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73029	15041-20001-35205	3644 S OVERLAND AVE	90034	5	120B161  1167	4314010077	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			PC Approved	01/05/2018 12:00:00 AM	ADDRESS	34.02231	-118.40953	01/05/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 8. Tenant panel feeders were changed to MC cable with AL conductors.*****Previous Work Description*****NEW 6 STORY 92 UNIT APARTMENT WITH 2500A 120/208 3PH-4W SERVICE.  VARIANCE TO SEPARATE FIRE ALARM PLANS HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73030	19041-20001-44260	3604 S FRANCES AVE	90066	11	114B153  1016	4246011025	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM			PC Approved	11/18/2019 12:00:00 AM	ADDRESS	34.00652	-118.43996	11/18/19$0 FEE PER SB1222CHANGES TO APPROVED SET CHANGES TO LOCATION OF PV MODULES.<<<Plan check for PV roof mounted system, PV system size: 14.35KW DC with 41 PV Modules and 41 Microinverters connected to 2 sub-panel>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73031	19041-10000-28608	9145 S BROADWAY	90003	8	094-5A203 248	6040037018	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM	07/25/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	33.95309	-118.27845	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73032	14041-20000-21537	11999 W SAN VICENTE BLVD 340	90049	11	129B141   174	4404025029	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			08/11/2014 12:00:00 AM			PC Approved	08/11/2014 12:00:00 AM	ADDRESS	34.05246	-118.47261	T.I. to existing high rise building.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under 14041-30000-19985	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73033	10041-20000-18342	14931 W CALIFA ST #A	91411	2	177A149   141	2243022022	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.17768	-118.4586	T.I. to existing office space.  Install new general/emergency lightings. Per Van Nuys Office EPC supervisor, plans do not show complete wiring to new light fixture.  EPC energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73034	14041-20000-31017	3415 S FIGUEROA ST	90089	9	120A201   206	5123023024	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/07/2014 12:00:00 AM	01/29/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.0215	-118.28051	PLANCHECK FOR POWER AND ENERGY. ADDITION OF A FLOOR BETWEEN BASEMENT AND SECOND. CLASSROOMS FOR USC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73035	18041-20000-05086	8501 N FALLBROOK AVE 2nd Floor	91304	12	192B097   587	2005022006	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	02/12/2018 12:00:00 AM		Issued	02/12/2018 12:00:00 AM	ADDRESS	34.22478	-118.62651	Renovation to 2nd floor interior corridor in (E) office lowrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73036	15041-10000-34614	3021 S VERMONT AVE	90007	8	120B197   393	5054038022	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Finaled	11/16/2015 12:00:00 AM	ADDRESS	34.02716	-118.2917	Remove HID light fixtures and replace w/ LED fixtures in (E) commercial space.  Energy plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73037	17041-20000-30985	11160 W VALLEY SPRING PL	91602	2	165B173   620	2366009013	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/04/2017 12:00:00 AM	PIN	34.14778513	-118.37384712	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73038	19041-20000-32147	20215 W GILMORE ST	91306	3	180B113   523	2134020007	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	08/30/2019 12:00:00 AM	ADDRESS	34.18929	-118.57394	Plan check for PV roof mounted system, PV System size: 3.96KW with 12 PV Modules and 6 Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73039	14041-10000-17373	12550 W FIELDING CIR 1-6	90094	11	102B161  1262	4211034053	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/27/2014 12:00:00 AM	03/12/2015 12:00:00 AM		Permit Finaled	07/29/2015 12:00:00 AM	ADDRESS	33.97815	-118.41197	PC FOR METHANE MITIGATION.NEW Type VA  6-unit  4-story  APARTMENT BUILDING with attached parking. 1 PANEL, 27 DEVICES.BUILDING APP#14010-10000-01304.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73040	10041-10000-23759	10958 S CENTRAL AVE	90059	15	088-5A211 269	6070006005	MR1-1	South Los Angeles	Southeast Los Angeles	Watts		2420.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM			PC Info Complete	11/30/2010 12:00:00 AM	ADDRESS	33.93551	-118.25399	"TI IN AN EXISTING KINTCHEN ""CHILI HOUSE"". PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73041	18041-10000-22614	13274 W FIJI WAY STE 300	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	08/14/2018 12:00:00 AM	ADDRESS	33.97902	-118.43558	PC FOR ENERGY ONLY, T-24. OFFICE TI ON THE 3rd FLOOR AREA; SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3811	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73042	13041-10000-16306	101 W WORLD WAY	90045	11	090B165    54	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	PIN	33.94482328	-118.40058888	LAX parking structure 101.  Replacement of older elevator motors, upgrading of lighting in elevator towers.  Title 24 plan check only, permit to be issued at electrical plan check counter. scope of work < 400A. 2 TOWERS FOUR FLOORS, ONE BUILDING ONE SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73043	11041-20000-14064	9301 N TAMPA AVE #13	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/07/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR T. I. TAKKEM'S SHOES UNIT#13	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73044	17041-20000-02244	3230 S OVERLAND AVE	90034	5	120B161    14	4314025043	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.04	Electrical	Electrical	Apartment			01/24/2017 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	ADDRESS	34.02892	-118.4146	"""0$ permit fees due to senate bill 1222 ""Plan check for a PV2 roof-mounted PV system. System size is 38 kWac and consists of (5) inverters, (158) modules, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73045	15041-10000-02951	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			01/30/2015 12:00:00 AM	03/24/2015 12:00:00 AM		Permit Expired	04/18/2017 12:00:00 AM	ADDRESS	34.09676	-118.29487	Plan check for Title 24 (energy). Project is the installation of exterior lighting. Total outdoor lighting area = 72,255 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73046	17041-20000-16697	22830 W DOLOROSA ST	91367	3	174B097   832	2042008079	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.16994	-118.62459	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.2 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73047	17041-10000-34266	742 S WESTLAKE AVE 1-37	90057	1	132A203   246	5142003007	R4-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Apartment			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	34.05473	-118.27626	PC FOR FA SYSTEM FOR APARTMENTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73048	17041-20000-20430	12301 W WILSHIRE BLVD 505	90025	11	126B145   293	4264020023	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.04271	-118.46948	Plan check for power and energy. TI to (E) medical office (dentist). New lighting (incl. emergency) and power throughout. T24 area - 1,082sqft. Article 517.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73049	16041-10000-28370	811 W WILSHIRE BLVD 2ND FLR	90017	14	130-5A209 205	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/10/2016 12:00:00 AM	10/03/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	FULL PC FOR POWER AND ENERGY. INTERIOR TI  FOR AN EXISTING COMMERCIAL BUILDING ON THE 2ND FLOOR ONLY (LOS ANGELES  TSC-702). SCOPE INCLUDES A NEW 600A DISTRIBUTION PANEL, NEW TRANSFORMERS, AND THREE NEW SUBPANELS. TOTAL AFFECTED AREA IS 17940 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73050	14041-20000-21049	12400 W WILSHIRE BLVD Ste 550	90025	11	126B145   524	4267035024	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			08/05/2014 12:00:00 AM			Not Ready to Issue	08/05/2014 12:00:00 AM	ADDRESS	34.04157	-118.47031	Office TI under 2008 Title 24 in an (E) highrise office building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73051	13041-20001-30599	5123 N BLUEBELL AVE	91607	2	171B161   718	2357001014	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2013 12:00:00 AM			PC Approved	11/22/2013 12:00:00 AM	ADDRESS	34.16371	-118.41065	((((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 19.6 KW AC USING 78 MODULES. USING 4 TRANSFORMERLESS INVERTERS. A SUBPANEL. 400A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73052	13041-10000-34677	1200 S GRAND AVE	90015	14	126A207   138	5139023907	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			12/12/2013 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.03989	-118.26331	FULL PLAN CHECK FOR  New 7 Story (5 Story over 2 Story Podium) Mixed Use Building w/ 287 Unit Apartment & Retail Building over two level parking basement. PROJECTED AREA FOR LIGHTING WORK IS APPOXIMATELY 344,451 SQ FT AREA. SERVICEbuilding permit under: 13010-10001-02721, DESCRIPTION LISTED AS 347 UNITS; ELECTRICAL PLANS WERE BASED ON CALCULATIONS FOR 300 UNITS (REFER TO SHEET 1E0.03 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73053	17041-20000-04020	9337 N HAYVENHURST AVE	91343	12	198B137   386	2687023024	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.24044	-118.49392	pv1install roof mounted pv system sized 3.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73054	19041-20000-24482	5440 N TROOST AVE	91601	2	174B169  1268	2348001037	RD1.5-1	South Valley	North Hollywood - Valley Village	Valley Village		1252.00	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM			PC Info Complete	06/25/2019 12:00:00 AM	ADDRESS	34.1697	-118.38649	T24 PLAN CHECK FOR OUTDOOR LIGHTING FOR EXISTING CHURCH PARKING LOT. LIGHTS ONLY. TOTAL SQUARE FOOTAGE = 16,152 SF.PLAN CHECK ONLY.  PERMIT ISSUED UNDER 19041-90000-24513.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73055	14041-20000-15883	833 S SPRING ST	90014	14	127-5A209 206	5144016054	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.04241	-118.25451	PC FOR TITLE 24 ENERGY AND EMERGENCY ONLY. EXISTING COMMERCIAL BUILDING SQUREFOOTAGE 1418.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73056	09041-10003-09842	111 S SAN PEDRO ST	90012	14	130-5A213 150	5161016014	[Q]C2-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM			PC Approved	03/30/2010 12:00:00 AM	ADDRESS	34.05022	-118.24128	Delta 2 Revision to approved plans revise plan to indicate existing 400A bus and change lighting ckt 20A C/B to 15A C/B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73057	15041-10001-29874	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM			PC Approved	12/10/2015 12:00:00 AM	ADDRESS	33.94221	-118.40701	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 8. REVISION TO LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73058	10041-10000-17596	1281 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.05078	-118.22567	Solar voltaic system installed on the roof of the building.  Consists of  8 modules,  8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73059	17041-20000-33086	6555 W BARTON AVE Suite 100	90038	4	144B185  1067	5532014041	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	01/10/2018 12:00:00 AM	ADDRESS	34.08785	-118.33475	Plan check for Title 24 only. Project site is an existing commercial commercial. Project scope is a tenant improvement. Total lighting area = 8,819 sq. ft.Note: Building application has been generated under 17016-10000-16257	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73060	14041-10001-24548	1420 S BONNIE BRAE ST	90006	1	127-5A201 187	5135006005	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2243.20	Electrical	Electrical	Apartment			09/08/2014 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.04374	-118.28124	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<INSTALL 25.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON AN APARTMENT BUILDING, INTERCONNECT WITH MAIN SERVICE SYSTEM.(100)MODULES: CANADIAN SOLAR 255 POLY(2) INVERTER(S): FRONIUS IG PLUS ADVANCED 11.4-1>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73061	19041-10000-20683	2425 E 12TH ST	90021	14	120A217    94	5168003014	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Closed	09/26/2022 12:00:00 AM	ADDRESS	34.02278	-118.22916	T-24, PC FOR ENERGY ONLY. INSTALLING OUTDOOR LIGHTING FOR PARKING LOT. AREA: 125,000 SQR FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73062	15041-10000-10182	5450 W PICO BLVD SUITE 102	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	10/15/2015 12:00:00 AM	ADDRESS	34.04862	-118.35714	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANEL.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1335.  SCOPE OF WORK TO BE PERFORMED IN SUITE 102	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73063	17041-10000-14387	5960 N CANOGA AVE	91367	3	177B105    79	2149002005	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.17881	-118.5972	PC for title-24, Energy only. T.I. TO EXISTING STARBUCKS W/OUTDOOR SEATING 8 TABLES & 16 CHAIRS.total affected area of 1801 sq.ft.installing new ligths receptacles on new circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73064	09041-10001-24421	1718 N VINE ST	90028	13	148-5A189  82	5546030027	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM			PC Approved	04/05/2011 12:00:00 AM	ADDRESS	34.10224	-118.32648	CHANGES TO PERMITTED SET OF PLANS- SERVICE IS 600A NOT 8OOA; CHANGES IN THELOADS SUPPLIED FROM PANEL MA; REVISED SERVICE LOAD SUMMARY((((((((((PLAN CHECK POWER AND ENERGY FOR INTERIOR REMODELING OF (E) RESTAURANT, BAR AND NIGHT CLUB.  VARIANCE TO SEPERATE FIRE ALARM SYSTEM HAS BEEN FILED.  LIGHTING SPECIFIED ON FIXTURE SCHEDULE SHALL HAVE PERMANENT FACTORY PRE-PRINTED INSTALLED MAX. WATTAGE UL LABELS, SUBJECT FOR FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73065	17041-20000-15951	14904 W CORONA DEL MAR	90272	11	123B129   854	4411029002	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		Yes	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2017 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	07/06/2021 12:00:00 AM	ADDRESS	34.03009	-118.52053	NEW 2-STORY S.F.D. WITH ATTACHED GARAGE AND A BASEMENT.  NEW 800A 208Y/120V SERVICE.  PLAN CHECK FOR POWER.BUILDING PERMIT APPLICATION UNDER 16010-30000-05769	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73066	18041-20001-36006	710 S SANTA FE AVE	90021	14	124-5A217 282	5166002018	(Q)C2-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM			PC Approved	10/24/2018 12:00:00 AM	ADDRESS	34.03414	-118.22981	Expedite per appliant request. Plan check for PV roof mounted on commercial building, system size: 9.712KW AC CEC with 37 Microinverters and 37 PV modules connected to existing 600A Service panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73067	14041-10000-20399	14701 W VENTURA BLVD	91403	4	166-5A149  17	2265001001	C2-1L, [Q]R3P-1, [Q]R3P-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.03	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	05/29/2015 12:00:00 AM	ADDRESS	34.15183	-118.45322	Title 24 plan check only.  Total area = 115 sq. ft.  TENANT IMPROVEMENT TO EXISTING BANK; ADDITION TWO (2) NEW ATAS (AMS WITH TELLER ASSIST) ADJACENT TO TELLER LINE AND IN NEW 24HR VESTIBULE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73068	13041-10000-14957	8915 N MURIETTA AVE	91402	7	195B153   432	2639024009	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2013 12:00:00 AM	06/07/2013 12:00:00 AM		Permit Expired	07/02/2015 12:00:00 AM	ADDRESS	34.23219	-118.44216	PV1 4.165KW XFRMLESS. 2STORY. NONSTD. ROOFMOUNT. (1)solaredge SE3800A-US and (17)TRINA TSM-245PC05.18} with optimizers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73069	14041-10000-10817	1762 S CRENSHAW BLVD	90019	10	126B185   679	5072001029	R3-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.10	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM	04/24/2014 12:00:00 AM		Permit Finaled	07/08/2014 12:00:00 AM	ADDRESS	34.04181	-118.32979	PV1 2.592kwac. 240V. microinverter. STD. 2story. Roofmount. [(12) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(12)modules: {EHS3-250}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73070	15041-20000-24480	1055 W 7TH ST 20th Floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			07/30/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.0507	-118.26334	TI to existing high rise commercial building (offices). Plan check for energy only. Adding new lighting including emergency. Total sqft 16,170.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73071	20041-10000-06724	550 S FLOWER ST 1st, 2nd,-& Roof	90071	14	130-5A209 186	5151024004	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.05028	-118.25708		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73072	14041-10000-09695	5850 N CANOGA AVE	91367	3	174B105     9	2149002016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.17678	-118.59723	Title 24 for a office buldg, lighting , energy, and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73073	10041-10000-21956	1616 E 15TH ST	90021	14	120A213    86	5130017011	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	11/08/2010 12:00:00 AM	ADDRESS	34.02421	-118.24251	REPLACE AN EXISTING FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73074	12041-20000-03412	6630 W FOOTHILL BLVD	91042	7	201A203   108	2564010016	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	05/01/2012 12:00:00 AM	ADDRESS	34.24647	-118.27676	Install new general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73075	19041-20000-52140	6624 W MELROSE AVE	90038	5	141B185   613	5524017020	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	03/04/2020 12:00:00 AM	ADDRESS	34.08331	-118.33948	Plan check for energy, new indoor lighting. Total lighing area: 2372 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73076	15041-20001-34162	11135 W BURBANK BLVD 1-70	91601	2	174B173   874	2337031007	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.17237	-118.37358	Revisions to approved plans - changes made to kitchen equipment/layout.  (((Plan check for power and energy. Project site is a new 4-story, 70-room hotel. Building is (1) level of above-ground parking and (3) levels of hotel rooms. Service size is 1600 Amps.Note: Building application has been filed under 15010-20000-03681)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73077	15041-10000-16863	10638 N VARIEL AVE	91311	12	207B105   284	2706018029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Expired	09/22/2017 12:00:00 AM	ADDRESS	34.26369	-118.5928	PV1, INSTAALL 13.08 KW DC ROOF -MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(40) MODULES:SUNPOWER SPR327NE-WHT-D(2) INVERTER: ABB PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73078	18041-10000-41022	6920 W SUNSET BLVD	90028	4	147B181   691	5548016043	C4-2D-SN, RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	10/26/2018 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.0978	-118.3411	REMOVE INDOOR-OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73079	16041-20000-02141	3144 W OLYMPIC BLVD	90006	10	129B193   326	5080022017	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			01/20/2016 12:00:00 AM	01/20/2016 12:00:00 AM		Issued	01/20/2016 12:00:00 AM	ADDRESS	34.05238	-118.30462	TI to existing commercial building (retail). Plan check for energy only. Adding new lighting including emergency. Total sqft. 692.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73080	19041-10000-19711	5975 N SHOUP AVE	91367	3	177B101   160	2040041008	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	10/25/2019 12:00:00 AM		Permit Finaled	12/07/2020 12:00:00 AM	ADDRESS	34.17892	-118.61491	FULL PLAN CHECK FOR SCHOOL TENANT IMPROVEMENT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA IS 14400 SQ.FTBUILDING # 21-5B#19016-10000-15462	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73081	13041-20001-20219	17309 W RAYEN ST	91325	12	195B133   185	2768018006	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.23232	-118.51173	New rooftop PV system for an existing single family residence.  System is Ungrounded and uses Power Optimizers. (CHANGES TO APPROVED SET OF PLANS. CHANGE ONLY MAIN SERVICE AND INTERCONNECTION. NO CHANGE IN PV SIDE OF SYSTEM. ))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73082	18041-10000-19377	3129 S EARLMAR DR	90064	5	123B165   376	4316009013	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	06/11/2018 12:00:00 AM		Issued	06/11/2018 12:00:00 AM	ADDRESS	34.03486	-118.40559	New rooftop solar system, 10.4 kW AC/ 10.725 kW DC. (33) modules, (2) 5.2 kW inverters, (1) 125A load centerPERMIT FEE  IS  $0 DUE TO SENATE BILL SB1221	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73083	11041-20000-02750	425 W 5TH ST	90731	15	015B201    58	7455004800	C2-1-CDO	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Info Complete	06/20/2011 12:00:00 AM	ADDRESS	33.73951	-118.28626	Install feeder system to HVAC equipment, new panels, and new ckts.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73084	11041-10000-03163	303 S GAFFEY ST	90731	15	018B197  1550	7451020033	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro	YES	2966.00	Electrical	Electrical	Commercial			02/17/2011 12:00:00 AM	07/14/2011 12:00:00 AM		Permit Finaled	09/26/2011 12:00:00 AM	ADDRESS	33.74122	-118.29251	EXTER REMODEL, UPGRADE EXISTING RESTROOMS AND SITE TO MEET CURRENT CODE AND INTERIOR UPGRAGE TO DINING AREA.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73085	12041-10000-04808	411 N TUALLITAN ROAD	90049	11	135B141   387	4403004001	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.06628	-118.48499	Plan check roof mounted 16.96KW photovoltaic system single family dwelling	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73086	13041-10001-31486	1236 W LEIGHTON AVE ste#2	90037	8	117B197  1164	5037003003	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Apartment			11/12/2013 12:00:00 AM			PC Approved	11/18/2013 12:00:00 AM	ADDRESS	34.01307	-118.29858	Express RSES plan check per applicant request.((PV1, Install 2 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Power-One AURORA PV1-3.0-OUTD-S-US.  8 modules Trina Solar TSM-250PA05.18.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73087	18041-10000-09154	1601 N GENESEE AVE	90046	4	147B177   623	5551014009	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	05/08/2018 12:00:00 AM	ADDRESS	34.10007	-118.35842	PC for two new tesla powerwalls 11.6kVA  for SFD with existing rooftop solar. Inspector to verify that 3/0 feeder between main panel and tesla gateway is a minimum 92ft lenght.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73088	14041-10000-00517	114 E 2ND ST	90012	14	130-5A213 205	5161026033	C2-4D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	09/04/2014 12:00:00 AM	ADDRESS	34.05056	-118.24413	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO RESTAURANT, PREVIOUSLY A CHURCH. building p# 13016-10000-09572	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73089	17041-10000-46590	9530 N DE SOTO AVE	91311	12	201B109   335	2748023043	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.24382	-118.58835	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73090	16041-20000-23053	21818 W YBARRA ROAD	91364	3	168B105   798	2171020038	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2016 12:00:00 AM	07/20/2016 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.15408	-118.6016	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 13 KW WITH 40 MODULES	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73091	16041-20000-12078	11433 W SATICOY ST	91605	6	186B169   234	2316009005	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.20859	-118.38041	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 3.8kW. Ungrounded system. (16) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73092	15041-20002-30833	6301 N OWENSMOUTH AVE	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/10/2017 12:00:00 AM			PC Approved	01/10/2017 12:00:00 AM	ADDRESS	34.18467	-118.60176	01/10/2017 Changes to an approved set of plans. Changes have been made to the lighting floor plan. All changes have been reflected onto the Title 24 Forms. *****Previous Work Description*****TENANT IMPROVEMENT FOR A (N) KITCHEN & SERVERY.  pc for power and energy. part of total ti package.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73093	15041-10005-18741	12415 N SAN FERNANDO ROAD	91342	7	219B149   666	2611007035	(T)(Q)C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Apartment			06/21/2017 12:00:00 AM			PC Approved	06/22/2017 12:00:00 AM	ADDRESS	34.29585	-118.45528	PLAN CHECK ONLY FOR ADDITION AND REMOVAL OF RECEPTACLES AND SWITCHES IN DWELLING UNITS. CHANGES CLOUDED UNDER DELTA 4-AFFECTED SHEETS (E3.00-E3.01)ORIGINAL PLAN CHECK 15041-10000-18741	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73094	14041-10000-01527	8500 W BEVERLY BLVD #641	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.07587	-118.37754	Tenant improvement of (E) 1063 s.f. retail space in a covered mall.  Title 24 plan check for changes to lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73095	17041-10000-30952	1272 W SANTA CRUZ ST	90732	15	018B193   789	7452006015	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Info Complete	08/29/2017 12:00:00 AM	ADDRESS	33.74423	-118.30361	PLAN CHECK FOR TITLE 24 ONLY FOR TI - SCHOOL TI .No change in parking,occupancy and floor area. - TOTAL AFFECTED AREA = 3959 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73096	18041-20000-12746	8511 N CRANFORD AVE	91352	6	192B165   246	2634040024	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Expired	05/18/2024 12:00:00 AM	ADDRESS	34.22485	-118.40073	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.35 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73097	19041-10000-52447	802 N BROOM WAY	90049	11	138B141   417	4494011023	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2019 12:00:00 AM	01/09/2020 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.07208	-118.48406	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 9.9KWdc (7.6KWac) USING 30 vVBHN330SA17 MODULES, 30 SE P400 POWER OTIMIZERS & 1 SE7600H-US CENTRAL INVERTER. ESS TESLA POWERWALL. CONNECTED TO A 200/225 AMP NEW SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73098	13041-10002-12776	5711 W CENTURY BLVD INTERNATL-BALLRM	90045	11	090B169    58	4125025035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	33.94573	-118.38128	MODIFICATION TO APPROVED SET OF PLANS. ADDITION OF TRACK LIGHTING. CIRCUITS CHANGED. LOCATION OF LUMINAIRES CHANGED. VARIANCE FOR CUSTOM CHANDELIERS TO BE FILED. PANEL IB1 UPDATED.**************************************************************PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING ON A HIGH RISE. BALLROOMS ON GROUND FLOOR. PLAN CHECK ONLY. PERMIT TO BE PULLED UNDER APPLICATION 13041-10001-12776. POWER PLAN CHECK UNDER APPLICATION 13041-10001-12776.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73099	19041-30000-09336	2029 S CENTURY PARK EAST 22nd Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	06/24/2019 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only. Project site is common area restrooms on the 22nd floor. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73100	15041-10000-04909	10040 N REMMET AVE	91311	12	204B105   823	2747010***	MR1-1	North Valley		Chatsworth		1132.13	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.25301	-118.60034	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 7556 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73101	16041-20001-17437	8500 S FIGUEROA ST	90003	8	097-5A201 184	6032035043	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM			PC Approved	04/25/2017 12:00:00 AM	ADDRESS	33.96105	-118.28251	"4.25.2017 - Plan check for modification to approved set. Update elevation diagram to show that service is not concrete pad mounted, it is instead mounted on a steel plate pad. Only change.========Plan check for power only. Project site is a new commercial building (building for school use). Work includes a new 800-amp service and associated distribution equipment.Note: Building application has been created under 16010-10000-00537""COMPLY WITH DEPARTMENT ORDER effective date 01/21/2016. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73102	11041-10000-04456	7300 W WORLD WAY WEST	90045	11	090B157    95	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/08/2011 12:00:00 AM	05/09/2011 12:00:00 AM		Permit Finaled	01/17/2012 12:00:00 AM	PIN	33.93847109	-118.41935625	REMODEL OF EXISTING HANGER FOR USE BY AMERICAN AIRLINES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73103	18041-10000-32165	3077 S UNIVERSITY AVE	90007	9	121-5A201 169	5123005030	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Issued	08/23/2018 12:00:00 AM	ADDRESS	34.02574	-118.28257	PLAN CHECK FOR ENERGY ONLY FOR - TENANT IMPROVEMENT AT 1ST FLOOR MEN'S RESTROOM - TOTAL AFFECTED AREA = 182 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73104	19041-10001-06395	6600 N TOPANGA CANYON BLVD # 2036	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM			PC Approved	04/10/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Supplement PC T-24 only. change to Ltg fixtures.  RETAIL STORE (2,638 SF) FOR SUITE 2036 TOTAL AFFECTED AREA = 2638 SFPermit issued under 19041-10001-06395	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73105	16041-30000-28568	2029 S CENTURY PARK EAST 31st FL-Lobby	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Issued	11/03/2016 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only in elevator lobby 31st floor in existing high-rise. Total lighting area: 340 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73106	19041-10001-14037	10657 N RUSSETT AVE	91040	7	207B189   739	2555030010	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2019 12:00:00 AM			PC Approved	07/11/2019 12:00:00 AM	ADDRESS	34.26319	-118.31924	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include derating the main breaker to 175A and adding load calculations.Note: PC only. Permit Fees are paid under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73107	14041-20000-25275	12318 N EL ORO WAY	91344	12	219B133   577	2608022021	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.41	Electrical	Electrical	1 or 2 Family Dwelling			09/15/2014 12:00:00 AM	10/06/2014 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.29446	-118.50438	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 6.8KW INTERCONNECTED WITH MSP.(30) HYUNDAI HIS-S250 MODULES(30) ENPHASE M215 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73108	15041-10000-09046	2520 N GLENDALE BLVD	90039	13	148-5A209 515	5440001003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1873.00	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	34.10299	-118.25902	Phase C: Plan check for power only , temp power form LADWP feeding 300KVA transformer is being removed and the exsiting transformer is reconnected back to the newly installed Switchboard MS from Phase B. ***NOTE. Phase C  permit should not be pulled  until Phase B permit is final)Reference PHASE B : #14041-10000-30810(((Service upgrade in an exsisting shopping center. Core & Shell only and title 24 outdoor area = 62,269 sq. ft.  ALL future TI's require complete electrical plan check.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73109	10041-10000-23969	6701 S CENTER DR WEST 12TH Flr	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM			PC Info Complete	12/02/2010 12:00:00 AM	ADDRESS	33.97907	-118.39369	TI IN AN EXISTING OFFICE AREA ON THE 12TH FLOOR.      PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.      THE ELECTRICAL PERMIT NUMBER IS 10041-90000-23099 AND THE FIRE LIFE SAFETY PERMIT NUMBER IS 10041-10000-23558.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73110	18041-10000-27859	1111 S EARLE ST	90731	15	015B205    18	7440032904	M3, [Q]M3-1	Harbor	2077.10, Port of Los Angeles			2077.10	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			Corrections Issued	08/28/2018 12:00:00 AM	ADDRESS	33.73322	-118.26208	Relocate existing Substation Equipment to a new location and reconnect to existing load at Port of LA.Equipment involved: 1,500 KVA, Med Voltage 4.8KV:480V Transformer, Distribution panels and loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73111	19041-20001-00700	13551 W CHANDLER BLVD pv1	91401	4	171B157  1144	2344006022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.16871	-118.42845	SUPPLEMENTAL PLAN CHECK ONLY FOR CHANGE TO APPROVED SET, REVERTING FROM PANEL UPGRADE TO EXISTING PANEL, AND DOWNSIZING MAIN CIRCUIT BREAKER TO 150A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73112	13041-10001-07933	4725 N WHITE OAK PL PV1	91316	5	168B129   496	2182022001	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2013 12:00:00 AM			Corrections Issued	06/28/2013 12:00:00 AM	ADDRESS	34.15629	-118.51902	Applicant submits for electrical plan check due to change of design from transformered inverters to transformerless.  {21 modules: Trina Solar TSM-245PC05/PA05.18} {Transformerless inverter: Power-One PVI-3.6}Original Work Description: INSTALL ROOF MOUNTED PHOTO VOLTAIC SYSTEM 5.145KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73113	18041-20001-48381	611 S WESTERN AVE	90005	10	135B193   910	5503031006	C2-2	Central	Wilshire	Wilshire Center-Koreatown		2117.04	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM			PC Approved	07/16/2019 12:00:00 AM	ADDRESS	34.06305	-118.30927	07/16/2019 Changes to an approved set of plans. Changes have been made to the lighting and power floor plans. All changes have been reflected onto the Title 24 compliance forms. Scope of work has remained the same.*****Original Work Description*****T24 PLAN CHECK FOR EXISTING RESTAURANT TOTAL SQFT'G = 8042	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73114	19041-10000-12786	15022 N SAN FERNANDO ROAD	91342	7	231B133    92	2601002002	M1-1	North Valley	Granada Hills - Knollwood	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.32931	-118.50453	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73115	17041-20000-11137	11101 W VENTURA BLVD UNIT 1	91604	2	162B173   321	2366024004	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.04	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM			PC Approved	04/06/2017 12:00:00 AM	ADDRESS	34.14131	-118.37198	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL SPACE. 986 SQFT.  UNIT 1	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73116	15041-20000-38128	12555 W JEFFERSON BLVD	90066	11	105B161  1047	4211005020	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Issued	11/12/2015 12:00:00 AM	ADDRESS	33.97954	-118.41361	Plan check for new fire alarm system. Fire devices: 150 and 1 Fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73117	18041-10002-22539	2626 S 7TH AVE	90018	10	123B189   770	5051001012	R3-1-O-HPOZ	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2189.00	Electrical	Electrical	Apartment			07/27/2018 12:00:00 AM			PC Approved	08/24/2018 12:00:00 AM	ADDRESS	34.03173	-118.32378	PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES REMOVAL OF AC DISCONNECT BY MSP. THIS IS PLAN CHECK ONLY. PERMIT PAID UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73118	17041-20001-42261	10205 N TELFAIR AVE	91331	7	204B161   330	2623011001	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.25561	-118.41738	expeditepv1install roof mounted pv system sized 10.4kw intetrconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73119	17041-20000-06018	445 S FIGUEROA ST 3rd Floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	03/13/2017 12:00:00 AM		Permit Finaled	04/14/2017 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for Title 24 only. Project site is a tenant space on the 3rd floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 229 sq. ft.Note: Building application has been generated under 16016-10001-05979	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73120	13041-20000-25438	26316 S ATHENA AVE	90710	15	033B193   674	7411024016	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2013 12:00:00 AM	09/23/2013 12:00:00 AM		Permit Expired	10/19/2015 12:00:00 AM	ADDRESS	33.78321	-118.30484	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.25KW. 29 MODULES AND 2 INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73121	18041-20003-06437	3139 N CHANDELLE ROAD	90046	4	156B177    37	5570023034	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM			PC Approved	07/20/2018 12:00:00 AM	ADDRESS	34.12757	-118.3647	07/20/2018 Changes to an approved set of plans. All changes have been clouded. Module model and manufacturer has changed and there has been an addition of a meter socket.*****Previous Work Description*****PC for changes to approved set. Removing all Tesla powerwalls, Tesla gateway and load center. New system is 11.4kW(ac)/13.325kW(dc) rooftop solar for SFD. All fees paid under master permit 18041-20000-06437.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73122	16041-10000-33538	806 E 3RD ST	90013	14	129A215   316	5163015028	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/21/2016 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	05/06/2019 12:00:00 AM	ADDRESS	34.04564	-118.23594	Full plan check. Connect 2 buildings to be just one building. Change of use from residential to live work, and mixed use. (6) live-work space and 7- future commercial space. (1) live-work and (7) commercial space will be under separate permit; However,  all design load is provided. 1600 MS 120/208 3PH 4W. Building is located on Methane Zone.((B# 16016-10000-15325))* Applicant provided a pre-made check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73123	10041-10000-21976	639 N LARCHMONT BLVD # 102 &-# 103	90004	4	141B189   437	5523012027	[Q]C2-1VL	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.08288	-118.32397	TENANT IMPROVEMENT AND CHANGE OF USE FROM RETAIL TO RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73124	10041-20000-15764	18206-18216 W VICTORY BLVD	91335	3	180B125   678	2124018070	R1-1	South Valley	Reseda - West Van Nuys	Tarzana		1329.00	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/12/2010 12:00:00 AM		Permit Finaled	09/15/2011 12:00:00 AM	ADDRESS	34.1863	-118.5297	Firealarm system for ISLAMIC center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73125	16041-10000-25223	19816 W VANOWEN ST	91306	3	180B113    54	2134003009	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	08/04/2016 12:00:00 AM	ADDRESS	34.19365	-118.56487	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING CENTRA INVERTER SYSTEM WITH TOTAL OF 24 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73126	14041-10000-09880	7307 N FIGUEROA ST # 201	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Finaled	06/10/2014 12:00:00 AM	ADDRESS	34.13662	-118.18837	"permit to be pulled at EPC counter only. Plan check for energy only. Emergency lighting for 1 story Tmobile store. BLDG#14016-10-01961: CHANGE OF USE FROM RESTAURANT TO RETAIL & TENANT IMPROVEMENT FOR (N) CELLPHONE STORE. ""COMPLY WITH DEPARTMENT ORDER effective date 07/09/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73127	12041-10000-03500	1800 S CENTURY PARK EAST #300-#400	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			02/15/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.06244	-118.41523	T.I. to an existing Office building on the 3rd and 4th floors.  New lighting and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Suites #300 and #400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73128	15041-20001-25720	1115 N MAHAR AVE	90744	15	033B213   316	7425031013	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			01/25/2016 12:00:00 AM			Corrections Issued	01/25/2016 12:00:00 AM	ADDRESS	33.78582	-118.24657	Plan check for lost set of plans. Plan check only. {{{{{{{Plan check for Title 24 only. Project site is an existing commercial building. Project scope is site lighting. Total outdoor lighting area = 22,414 sq. ft.}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73129	15041-10000-20012	1099 S GRAND AVE	90015	14	127-5A207 265	5139008001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Expired	07/20/2017 12:00:00 AM	ADDRESS	34.04179	-118.26214	Design Build: Power plan check per applicant request for temp power; Main scope includes (1) panel and (2) 25-hp elevators.Reference to original permit #: 14041-10000-30557	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73130	12041-10001-12954	19780 S PACIFIC GATEWAY DR	90502	15	057B197    48	7351034069	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Info Complete	09/19/2012 12:00:00 AM	ADDRESS	33.85141	-118.29512	(((((  Addition of 15 kva xfmr, 3 panel and three ckts.))))))  Split 800A service into two 400A meters. Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73131	13041-10001-17136	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			01/16/2014 12:00:00 AM			PC Approved	01/29/2014 12:00:00 AM	ADDRESS	34.01118	-118.33649	Only Delta 3 chnages to approved set remove Transformer from electricla room to other room and mounted on platform.  Transformer is class 155 which falls under exeption 2 of section 450.21 of NEC.  tap rule applies to transformer now on secondary.  Panels and boards are still within AIC rating.  Permit is existing , This plan cehck only.>>>>>T.I. to restaurant.  Install new panels, transformer, and branch with panel bus rating at 600A and load exceeds 400A.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73132	18041-20000-23226	21331 W COSTANSO ST	91364	3	171B105   167	2167002037	(Q)C1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			06/21/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Re-Activate Permit	10/09/2018 12:00:00 AM	ADDRESS	34.16689	-118.59684	Plan check for a PV1 roof-mounted PV system. System size is 16.6 kWac and consists of (3) inverters, (58) modules, and (2) load centers.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73133	13041-10002-31154	5949 N VAN NUYS BLVD	91411	4	177A151   145	2244001030	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			PC Approved	11/13/2014 12:00:00 AM	PIN	34.17890191	-118.44917219	"Plans were revised to show that PV System  meter and disconnect are now rated 800A. Wiring have been changed to reflect these changesPV2 (1) 500KW INVERTER 1284 MODULES AND 13 COMBINER BOXES"" $0 PERMIT FEE IS DUE TO THE 2012 SENATE BILL NO. 1222"""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73134	17041-20000-10068	9171 N DE SOTO AVE BLDG B	91311	12	198B109   136	2746009046	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			04/12/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Issued	12/01/2017 12:00:00 AM	ADDRESS	34.23778	-118.5888	(N) 1 STORY TIRE SHOP.  Plan check for power and energy.  Building B.  Building A permit is being submitted concurrently on same set of plans.  Building permit filed under 17010-20000-00223.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73135	18041-20000-20095	8811 W BURTON WAY	90048	5	138B169   687	4334011063	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	07/06/2020 12:00:00 AM	ADDRESS	34.07249	-118.38417	Plan check for Title 24 Energy only in existing building T.I. ground floor level. Total area: 4775 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73136	19041-20000-02199	8730 S FIGUEROA ST	90003	8	096A201   102	6038002048	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	Apartment			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	33.95785	-118.2825	Plan check for new fire alarm system, for 3 story building 5 units apartment. Total Fire alarm devices: 26  and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73137	13041-20000-31058	8505 W FOOTHILL BLVD	91040	7	207B189  1077	2555033031	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.25989	-118.31823	T24 FOR EXISTING OUTDOOR CANOPY FOR GAS STATION. MOUNTING ABOVE GRADE LEVEL PER APPLICANT. RETROFITTING LIGHTS AND RECONNECTING TO EXISTING CIRCUIT AND TIMECLOCK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73138	15041-20000-25940	5112 N MAMMOTH AVE	91423	4	171B157   775	2269001026	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	09/25/2015 12:00:00 AM	ADDRESS	34.1634	-118.43229	Installation of new roof mounted solar PV array.  Total system size = 5.45 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73139	15041-20000-27278	8907 S SEPULVEDA BLVD #8907	90045	11	096B165  1035	4122036031	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	33.95566	-118.3965	Plan check for title 24 only for existing retail space. Total indoor area: 2,233sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73140	17041-20000-41212	1901 S AVENUE OF THE STARS 19th floor	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.05949	-118.41705	Plan check for energy only. TI to office on 19th floor of high rise building. New lighting (incl. emergency) - 8,710sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73141	12041-10000-24112	1452 W KNOX ST Bldg C	90501	15	057B193   126	7351003010	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM	12/18/2012 12:00:00 AM		Permit Finaled	10/21/2013 12:00:00 AM	ADDRESS	33.85386	-118.30152	Installing new motors and panels for mixing machine. EPC is for power. (plan check per applicant request)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73142	16041-20001-18360	6600 N TOPANGA CANYON BLVD System B	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	4/5/2018changes to an approved set of plans.  changes to downsize total system size to 2.0Mw.This is system B all changes are clouded.This is plan check only.(((Plan check for PV carport ground mounted system in Topanga Mall Parking Lot. System size: 386kW with 1,701 modules and 11 inverters(33.3kW) and 1 inverters(20.0kW)This is system B part of larger system)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73143	15041-20000-11596	6256 N TOPANGA CANYON BLVD Ste 1240C	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	07/30/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	Plan check for power and energy. Project scope is a tenant improvement (first time tenant) to an existing commercial space. Project includes the installation of (3) new panels and associated loads, and a total lighting area of 3,678 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73144	16041-10000-30473	10201 W PICO BLVD BLDG 103	90064	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	ADDRESS	34.04994	-118.41129	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES REMOVING AND REPLACING ALL EXISTING ELECTRICAL EQUIPMENT ON THE 3RD FLOOR OF A COMMERCIAL BUILDING. TOTAL AFFECTED AREA IS 52845 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73145	17041-10000-41756	1632 N FORMOSA AVE	90046	4	147B181   283	5548008038	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.1008	-118.34665	Remove Outdoor HID fixtures and replace with new LED fixtures. T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73146	14041-20000-29946	1714 W MIDDLETON PL	90062	8	117B193  1214	5035023004	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2314.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.01543	-118.31143	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.3 KW INTERCONNECTED WITH MAIN SERVICE PANNEL(20) SOLARWORLD 250W MODULES(20) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73147	19041-10000-50286	8020 W MANCHESTER AVE	90293	11	096B153   618	4118002101	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	03/04/2020 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	33.95927	-118.43572	$0 FEE DUE TO AB1414. PV2. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 246 MODULES (SPR-E20-435), WITH 246 OPTIMIZERS (SE P730) AND 2 INVERTERS (SE 43.2K EACH). SYSTEM SIZE IS 86.4KW AC AND 107KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73148	10041-20000-18355	11835 W VANOWEN ST	91605	6	183B169   615	2321021006	R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Public Safety Only			09/16/2010 12:00:00 AM	09/16/2010 12:00:00 AM		Permit Finaled	04/06/2011 12:00:00 AM	ADDRESS	34.19408	-118.39131	Plan check new installation of fire alarm system for 10-unit apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73149	13041-10000-02604	3145 N GLENDALE BLVD	90039	13	154-5A207 302	5435027019	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			02/01/2013 12:00:00 AM	02/01/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.11711	-118.26218	EXISTING RETAIL CHANGE OF USE TO JUICE BAR, NO SEATING. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73150	10041-10000-07715	1329 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 401	5173029906	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.05086	-118.22426	INSTALLATION OF A  1.8 KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF AN APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73151	14041-20001-19790	13361 N GLENOAKS BLVD BLDG A	91342	7	225B145   449	2501022077	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM			PC Approved	08/28/2015 12:00:00 AM	ADDRESS	34.3146	-118.45921	08-28-2015 Change to approved set of plans. Changes include Secondary Transformers feeder size from  500kcmil to 600kcmil. Changes apply to delta 5 only. {{{{{PLANCHECK FOR POWER AND ENERGY FOR A MIDDLE SCHOOL. under 2013 energy code.}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73152	13041-10000-26575	1557 S RIO VISTA AVE	90023	14	120A219    53	5169010012	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/25/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.02169	-118.22216	Remove HID light fixtures and install new fluorescent fixtures.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73153	14041-20003-16819	1513 N VINE ST	90028	13	147A187   599	5546010***	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM			PC Approved	11/10/2014 12:00:00 AM	ADDRESS	34.09851	-118.32696	11/10/2014 - Plan check only. Delta 2 changes only. Title 24 only.[CHANGE IN LOCATION OF LIGHITING FIXTURES DUE TO CHANGE IN BATHROOM LAY OUT. NO CHANGE IN DENSITY AND LIGHTING LOAD. CHANGE OF CONTROLS. PC ONLY. ENERGY ONLY][[Change of use from restaurant to beauty salon in (E) commercial tenant space.  Plan check for Title 24 for changes to lighting system.]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73154	13041-20001-23815	17828 W TULSA ST	91344	12	210B129   831	2712020004	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.26835	-118.52265	PV1 TRANSFORLESS SYSTEM. 4 STRINGS FOR 1 INVERTER. 25 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 8.175KW. 400A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73155	17041-10003-44422	5027 N MONTEZUMA ST	90042	1	151-5A225  52	5469009037	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.11101	-118.20559	CHANGES TO AN APPROVED SET TO REFLECT FIELD INSTALLATION. ALL CHANGES ARE CLOUDED UNDER DELTA 4. SCOPE INCLUDES CHANGES TO MODULES SIZE FROM 295 TO 305.ADDING ONE ADDITIONAL SOLAR MODULE, RELOCATING INVERTER ON THE SITE LAYTOUT, AND RELOCATING MODULES ON THE ROOF-LAYOUT. SYSTEM SIZE IS 4.575KWdc / 3.80KWac.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73156	14041-20000-12800	17915 W BURTON ST	91335	12	192B129   415	2101019017	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1313.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.22015	-118.52343	PV1 SINGLE FAMILY DWELLING. 3.8 KW AC USING TRANSFORMERLESS INVERTER. USING NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73157	11041-20000-20235	14557 W VICTORY BLVD	91411	6	180B149   841	2236023014	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.18686	-118.45068	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73158	19041-10000-50878	600 S CURSON AVE	90036	4	135B177   426	5508015006	QPB-2, R4-2	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			12/10/2019 12:00:00 AM	02/12/2020 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	34.06466	-118.35444	NEW OUTDOOR LIGHTING PLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73159	14041-10000-09971	3820 N LOMITAS DR	90032	14	145-5A231 132	5302023009	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.01	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.09094	-118.18639	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 3.6KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73160	16041-20000-02665	3400 N DIVISION ST	90065	1	150A217   231	5464024021	R2-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.04	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2016 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	PIN	34.1048801	-118.22792147	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 0.86kW, ungrounded. Using one Enphase M215 on each pv module. (4) 250W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73161	16041-10000-44675	3704 N BARHAM BLVD (BUILDING-E)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.14076	-118.34141	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73162	14041-20000-30967	7741 N CASE AVE	91352	6	189B173   763	2315006004	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.20	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.21145	-118.37264	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.3kW. Ungrounded system.20 EnPhase M215-IG microinverters with 20 250W pv modules across 2 strings (8+12).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73163	11041-20002-11320	4112 N WHITSETT AVE	91604	2	165B165  1171	2367009010	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1435.00	Electrical	Electrical	Apartment			01/14/2014 12:00:00 AM			PC Approved	01/14/2014 12:00:00 AM	ADDRESS	34.14529	-118.40503	Chnages to single line diagarm, Delta 3 only ( requested by LADWP ) for the applicant to install UGPB and provide under ground conduit for future use.  , No change of service , load calculation or fault current.  Aproved sheet is attached to teh existing approval set.>>>>>>New apartment with 15 units.  New 800 Amp service.  Plan check for power and energy.<<<<<	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73164	15041-20000-24359	15232 W FOOTHILL BLVD	91342	7	228B145   794	2502001***	(Q)RD2-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	34.32292	-118.46695	Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73165	18041-10001-35994	2231 S BARRINGTON AVE	90064	11	123B149   480	4260012027	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM			PC Approved	03/19/2019 12:00:00 AM	ADDRESS	34.03337	-118.44727	Change to approved set of plan by modifying fault current on single line, floor plan also being updated. All changes under delta-2 only. (((FULL PLAN CHECK FOR POWER AND ENERGY FOR - CHANGE OF USE FROM (E) WAREHOUSE/RETAIL TO COMMERCIAL OFFICE SPACE AND STUDIO W/OUTDOOR PATIO - TOTAL AFFECTED AREA = 25458 SF WITH APPROX 450A OF CONNECTED LOAD .)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73166	17041-10002-17278	41 E OZONE AVE	90291	11	111B141   730	4286018026	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM	03/08/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	33.99605	-118.48001	Supplemental PC for changes to approved set. Changes include downsizing main breaker to 125A, addition of new distibution panel for house loads and three AC disconnects. All changes clouded under delta C,D,E. Inspection to verify location of new distribution panel on inside of house.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73167	11041-10000-07643	6355 N DE SOTO AVE Bldg 2 & 3	91367	3	180B109   600	2149003011	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM			PC Approved	04/19/2011 12:00:00 AM	ADDRESS	34.18639	-118.58869	The plan check fee is for buildings 2 and 3,  The permit for this application number is for building 3 only.  The permit for building 2 is on express permit 11041-10000-07635.  Plan check for building 2 and 3.  224 units new apartment bldg no retail, 4 story  bldg over one story garage, need to submit a variance for fire alarm. Bldgs   2 and  3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73168	14041-10000-11290	1016 W VIA LA PAZ	90732	15	021B197    53	7445015052	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	07/12/2014 12:00:00 AM	ADDRESS	33.75656	-118.29978	PV1 ROOF MOUNTED TRANSFORMERLESS STANDARD PLAN. TOTAL SYSTEM SIZE 3.8KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73169	17041-10000-17536	11967 W SUNSET BLVD	90049	11	135B141   909	4402010016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	10/12/2017 12:00:00 AM	ADDRESS	34.06222	-118.47401	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73170	19041-10001-14218	17200 W VENTURA BLVD 224	91316	5	168B133    49	2289005059	(Q)C4-1VL, (Q)P-1, (Q)P-1VL, C2-1VL, C4-1VL, P-1, P-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.16035	-118.50769	"Change to an approved set by updating the lighting and power plan. All changes under delta-8,9,11, and 12 only.(((PC FOR T.I. FOR EXISTING RESTAURANT TO PANDA EXPRESS.SCOPE INCLUDES NEW PANELS, CIRUCITS AND LIGHTS. TOTAL AFFECTED AREA 2574 SQ.FT B#19016-10000- 11051 ""COMPLY WITH DEPARTMENT ORDER effective date 12/10/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".   CEIS Case Number is 838199.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73171	16041-20001-02255	11831 W FOLKSTONE LANE	90077	5	153B141   114	4378037079	(Q)RD6-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.1153	-118.47509	EXPEDITE PER APPLICANT REQUEST[Install a solar array on a SFD. System size: 12kW, ungrounded system. (50) EnPhase M250 microinverters with (50) 285W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73172	16041-20000-03716	5161 N LANKERSHIM BLVD 1st Floor	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			02/02/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	34.16452	-118.37469	TI to (E) 6,525 sq ft. commercial office space.  Floor 1 of 3 floor TI multi-phase project.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73173	18041-10000-06179	1925 S TUDOR LANE	90034	10	126B173  3095	6207036031	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM			Reviewed by Supervisor	02/28/2018 12:00:00 AM	ADDRESS	34.04074	-118.37113	PC for 3.8kW system PV solar for SFD. Installing new 16 modules (5.04kW(DC)), 200A load center, 3.8kW inverter and Tesla powerwall. Tesla Powerwall covered under 18041-10003-06179.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73174	17041-10000-15799	6081 W CENTER DR ST 206	90045	11	102B165    66	4104001035	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			05/11/2017 12:00:00 AM	06/20/2017 12:00:00 AM		Permit Finaled	09/27/2018 12:00:00 AM	ADDRESS	33.97811	-118.39245	Title 24 plan check.  T.I. to existing retail space.  New 75 kVA transformer and two new subpanels feeding lighting, receptacles, and two electric kilns.  Total area = 945 sq. ft.     Building permit #17016-10000-08753	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73175	15041-20000-41839	8830 N FARRALONE AVE	91304	12	195B101   158	2010006033	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.23112	-118.60953	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (25)MODULES-SW 285(25)OPTIMIZERS-P300(1) inverter SE 7600US-240VStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73176	19041-10001-43529	5825 W SANTA MONICA BLVD	90038	13	144B189   595	5534017022	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM			PC Approved	11/25/2019 12:00:00 AM	ADDRESS	34.09089	-118.31662	ROOF TOP SOLAR PLAN CHECK FOR 40KWac (46.129 KW CEC AC) (51.48 KWdc) USING 156 AXITEC-AC-330P/156-72S MODULES, 78 SOLAREDGE P730 OPTIMIZERS, AND 2 SOLAREDGE SE20KUS INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73177	16041-10000-20122	2500 E 24TH ST	90058	14	117A217    28	5168021001	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.01614	-118.22766	PC for T-24 only, remove HID fixtures and replace with LED fixtures. Total area: 17,000 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73178	18041-20000-28794	11430 N RIVERWOOD DR	91342	7	213B189    37	2551005008	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	PIN	34.27777034	-118.31871355	pv1install roof mounted pv system sized 6KW AC interconnected with msp.(20) solar world 350W modules(20) P400 optimizers(1) solaredge SE600H inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73179	18041-20000-43706	1925 S CENTURY PARK EAST 22nd flr	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	12/21/2018 12:00:00 AM	ADDRESS	34.06066	-118.41426	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73180	16041-10001-25999	5334 N ALHAMA DR	91364	3	171B105   311	2167024022	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/02/2016 12:00:00 AM			PC Approved	11/02/2016 12:00:00 AM	ADDRESS	34.1663	-118.59282	11/02/2016 Plan check for lost set of plan. {{{{{Plan check for Power only. Main Service upgrade to 1200A, 120/280V, 3ph, 4W on (E) commercial building.}}}}}	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73181	13041-10000-16397	750 S LAMAR ST OUTBOUND-CANOPY	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (3b.)  OUTBOUND CANOPY. ALL LIGHTING IS OUTDOOR CANOPY. EXCEMPT FROM TITLE 24 PART 6.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73182	15041-20001-33696	9623 N DONNA AVE	91324	12	201B121   584	2762033024	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2015 12:00:00 AM			PC Approved	10/27/2015 12:00:00 AM	ADDRESS	34.24546	-118.54767	EXPEDITE PER APPLICANT REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.  THIS PV SYSTEM IS IN ADDITION TO THE EXISTING PV SYSTEM.(13) TRINA SOLAR MODULES TSM-255(1) ABB 3KW INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73183	16041-10000-16730	1410 W 82ND ST	90047	8	099B193  1297	6034013010	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Refund in Progress	07/13/2016 12:00:00 AM	ADDRESS	33.96448	-118.30073	PV1 4505W DC/ 3800W AC roof-mounted system with (17) Canadian Solar modues, power optimizer and (1) SE3800A-US inverter. interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73184	14041-20000-15828	2 S CHESTER PL	90007	1	123A203   140	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			06/13/2014 12:00:00 AM			PC Approved	06/13/2014 12:00:00 AM	ADDRESS	34.03178	-118.27669	TI to existing office space in single story university campus bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73185	16041-10001-07261	1218 S SYCAMORE AVE	90019	10	129B181   179	5084029024	R2-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			03/09/2016 12:00:00 AM	03/09/2016 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.05277	-118.34616	3/9/16: Change to approved set: adding 125A subpanel.**PV1 SFD TOTAL SYSTEM SIZE 5.76KW AC USING MICROINVERTER SYSTEM. ENPHASE M250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73186	15041-10001-37851	2124 W 84TH ST	90047	8	097-5A191  53	6035021009	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2016 12:00:00 AM			PC Approved	03/21/2016 12:00:00 AM	ADDRESS	33.96258	-118.31645	01/27/16PV1, PLAN CHECK ONLY MODULES WERE REDUCED FROM 12 TO 11 MODULES, TOTAL SIZE IS 3.8KW. (11) MODULES-YINGLI ENERGY YL255P-29B(1)INVERTER-SOLAREDGE SE3800A-US NOTE: PERMIT FEES PAID UNDER EXPRESS PCIS#15041-70000-37851 / X15SL03905(((((Install a roof mounted photovoltaic system to existing single family dwelling (3.06       KW)Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73187	14041-10000-12028	1149 S HILL ST # 400	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Expired	06/08/2016 12:00:00 AM	ADDRESS	34.03926	-118.26099	permit to be pulled at EPC counter only. Plan check for energy only. Emergency lighting in a highrise building. Less than 400A per applicant but other work is being done in the building under separate projects. BLDG#14016-10-06774:TENANT IMPROVEMENT ON SUITE 400, NEW INTERIOR NON-BEARING PARTITIONS, REWORK CEILING, MILLWORK AND FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73188	18041-10000-08610	8100 N BALBOA PL	91406	6	189B133     9	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/09/2018 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	34.21802	-118.50102	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. TOTAL AFFECTED AREA IS 40400 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73189	16041-20001-34970	18336 W SHERMAN WAY	91335	3	183B125   199	2125003015	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	ADDRESS	34.20097	-118.53297	9.20.2017 - Plan check for changes to approved set. Update sheet E0.5 to correct project name/address on T-24 documents - only change.====Plan check for power and energy. Addition/TI to laundromat. New 800 distribution and loads. New lighting (incl. emergency). 4,782sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73190	17041-20000-18322	9241 N KENNY CT	91343	7	198B145   477	2651001264	(T)(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2017 12:00:00 AM	06/01/2017 12:00:00 AM		Permit Finaled	11/29/2017 12:00:00 AM	ADDRESS	34.23871	-118.45932	Plan check for solar pv system, roof-mounted on SFD.3.84kW ungrounded sysetm. (12) 320W AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73191	10041-10000-11798	445 S FIGUEROA ST 9th floor	90071	9	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00, 2077.10	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM	06/28/2010 12:00:00 AM		Permit Finaled	08/10/2010 12:00:00 AM	ADDRESS	34.05295	-118.25675	T-24 and emergency lighting plan check for a portion of the 9th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73192	18041-20000-05397	22500 W FRIAR ST	91367	3	177B101    10	2039025004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	34.1854	-118.61709	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (2) inverters, (79) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73193	18041-20000-00596	16111 W MEADOW VIEW DR	91436	5	165B141   561	2285014033	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			Reviewed by Supervisor	01/19/2018 12:00:00 AM	ADDRESS	34.15014	-118.48406	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 15.84	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73194	13041-10000-13609	117 E WINSTON ST	90013	14	129A213   226	5148008010	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	06/26/2013 12:00:00 AM	ADDRESS	34.04713	-118.24718	TI for restaurant in basement and ground floor.  Tenant panels being moved.  New receptacles, disabled lift, compressors on roof, and insta-hots.  Newly connected load < 400A.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.  Power plan check also to be completed under 13041-10000-13637, as A-2 occupancy with > 100 occupant load was not discovered until after applicant had paid for OTC submittal.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73195	11041-20000-27170	4225 N COLDWATER CANYON AVE	91604	5	165B161   977	2375022036	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	12/21/2011 12:00:00 AM		Permit Finaled	03/22/2012 12:00:00 AM	ADDRESS	34.14586	-118.41392	T.I. IN (E) OFFICE:  REMOVE, RE-INSTALL BEAM AND PARTITIONS. FRAME NEW PAD FOOTING AS NEEDED.  ALL WORK PER ENGINEERINGenergy plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73196	19041-20000-01006	649 S ANDERSON ST	90023	14	124-5A219  35	5171017002	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			Reviewed by Supervisor	02/06/2019 12:00:00 AM	ADDRESS	34.03708	-118.22337	Plan check for power and energy for hydroculture, service 800A, Titak area:2363 sq ft. b#19016-20000-00572	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73197	10041-20000-02878	3000 S SEPULVEDA BLVD	90034	5	120B157   251	4251011037	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			02/18/2010 12:00:00 AM	03/10/2010 12:00:00 AM		Permit Finaled	05/11/2010 12:00:00 AM	ADDRESS	34.02726	-118.42829	Wells Fargo Bank remodelEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73198	14041-20000-26403	5455 N CALVIN AVE	91356	3	174B117   510	2163003044	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.17032	-118.55648	PV1.  Install 6.7 kW roof-mounted, utility-interactive PV system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73199	18041-10000-10974	944 E PICO BLVD #4	90021	14	123A211   265	5132018034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Issued	03/27/2018 12:00:00 AM	ADDRESS	34.03051	-118.24925	PLAN CHECK FOR TITLE 24 ONLY - REMOVE HID FIXTURES AND REPLACE WITH LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73200	11041-10001-02944	4176 W VENICE BLVD	90019	10	126B185   229	5072003027	C2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM			PC Approved	07/06/2012 12:00:00 AM	ADDRESS	34.04437	-118.32824	Plan check only. Revision to approved plans to use steam generator and skid equipment for soil vapor extraction site.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73201	15041-20000-25435	20848 W VERCELLI WAY	91326	12	213B109   323	2701066011	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	09/30/2015 12:00:00 AM	ADDRESS	34.27707	-118.5875	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (18) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73202	18041-10000-18952	3465 W 6TH ST #110	90020	10	135B197   995	5502020016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.06373	-118.29761	TENANT IMPROVEMENT IN EXISTING RESTAURANTPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73203	15041-10000-37842	13420 W SATICOY ST	91605	2	186B157   183	2303024011	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	03/23/2016 12:00:00 AM	ADDRESS	34.20861	-118.42526	T-24, TI TO AN(E) SINGLE STORY COMMERCIAL BUILDING.  SCOPE INCLUDES NEW LIGHTING NEW CONTROLS TO NEW PANELS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 9785.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73204	13041-10001-35361	656 S AVENUE 61	90042	14	150A233   129	5312026039	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			Reviewed by Supervisor	01/07/2014 12:00:00 AM	ADDRESS	34.10554	-118.18086	PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformerless inverter: Solaredge SE 5000A-US. (18) modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73205	17041-30000-24621	15343 W VOSE ST	91406	6	183B145   228	2222032013	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.19856	-118.46789	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (35) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73206	15041-10000-33095	723 N WILCOX AVE	90038	4	141B185   475	5533035009	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	02/08/2016 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.08413	-118.3311	NEW METHANE GAS DETECTION SYSTEM TO A NEW 4 STORY APARTMENT BUILDING. TOTAL NUMBER OF DEVICES 12 AND NEW CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73207	13041-20000-29089	23030 W BURTON ST	91304	12	189B097    52	2014038014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.21813	-118.62933	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE8.25 KW. 3 STRINGS 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73208	13041-10000-12372	6476 N ELLENVIEW AVE	91307	3	180B089   741	2032024005	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2013 12:00:00 AM	05/31/2013 12:00:00 AM		Permit Finaled	06/21/2013 12:00:00 AM	ADDRESS	34.18778	-118.65704	PV1 11.76KW ROOFMOUNT. NONSTD. 1STORY. CENTRALINVerter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73209	18041-20000-41358	3718 S BEETHOVEN ST	90066	11	111B153   399	4245016019	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.00215	-118.44284	Plan check for a PV1 roof-mounted PV system. System size is 4.32 kWdc/3.84 kWac and consists of (12) AC PV modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73210	19041-20000-01681	1151 N GORDON ST	90038	13	144B189   414	5534014003	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			01/15/2019 12:00:00 AM			Verifications in Progress	10/04/2019 12:00:00 AM	ADDRESS	34.09224	-118.32023	Plan check for power and energy . Service size: 600A 120/240V.***************Building Work Description**********************for 14 units multi-family 5 story  buildingFire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73211	19041-20000-53222	6505 W WILSHIRE BLVD BASEMENT &-1ST FLOOR	90048	5	135B173   795	5510023025	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			PC Info Complete	12/24/2019 12:00:00 AM	ADDRESS	34.06416	-118.37019	TENANT IMPROVEMENT IN EXISTING OFFICE AREA ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73212	15041-10000-43063	9620 W CEDARBROOK DR	90210	4	150B161    95	4387022023	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Expired	01/24/2018 12:00:00 AM	ADDRESS	34.10764	-118.40573	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 7.6KWAC. 36 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73213	16041-20001-18340	6600 N TOPANGA CANYON BLVD System A	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM			PC Approved	04/24/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	4/5/2018changes to an approved set of plans.  changes to down size total system size to 2.0Mw. this is system Aall changes are clouded.  This is plan check only.(((Plan check for PV carport ground mounted system in Topanga Mall Parking Lot. System size:1.2MW with 5,829 modules and 36 inverters(33.3kW) and 3 inverters(20.0kW)This is system A.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73214	10041-10000-24693	1209 E 8TH ST	90021	14	124-5A213 359	5146006014	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM			PC Approved	12/13/2010 12:00:00 AM	ADDRESS	34.03476	-118.24443	T-24 lighting plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73215	18041-10000-33164	108 S FREMONT PL WEST	90005	4	132B185   290	5090018010	RE20-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2018 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	02/26/2020 12:00:00 AM	ADDRESS	34.05945	-118.32826	Permit fee is $0.00 due to Senate Bill 1222NEW ROOF MOUNTED 16.8 KW PV SYSTEM WITH 56 MODULES and MICROINVERTERS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73216	12041-20000-07822	1835 S SEPULVEDA BLVD	90025	5	126B153   135	4323026019	M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			04/05/2012 12:00:00 AM	07/18/2012 12:00:00 AM		Permit Finaled	10/23/2012 12:00:00 AM	ADDRESS	34.04494	-118.44233	"Tenant improvement. Remodel of a lounge area. Kids club. Relocation of meeting room. Low-rise commercial. METHANE BUFFER ZONE. Plan check for energy and power. 6288 conditioned sqft.""COMPLY WITH DEPARTMENT ORDER effective date 01/03/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73217	16041-10000-17734	2319 S CENTRAL AVE Unit-2	90011	9	120A211   423	5131020001	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.02094	-118.25405	Energy plan check for a donut shop (restaurant) T.I.  Total area is 1175 SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73218	15041-10000-33019	3350 W WILSHIRE BLVD	90010	10	132B197    47	5094007001	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM	09/12/2016 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM	ADDRESS	34.0615	-118.29586	CONVERSION OY 12-STORIES/BASEMENT OFFICE/GARAGE TO 216 ADAPTIVE REUSE UNITS AND RETAILS ON THE 1ST FLOOR.BLDG PERMIT 13016-10000-26033	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73219	16041-20000-21244	10358 W DIAMOND ST LOT 20	90012	7	204B165    40	2537003001	(T)(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	12/07/2016 12:00:00 AM				"PV1. ROOFMOUNTED SOLAR INSTALLATION. SYSTEM SIZE: 3.18 KW.  BUILDING PERMIT :SMALL LOT SUBDIVISION , NEW 2-STORY 21' X 49' SFD/ GAR.  ""SMALL LOT SUBDIVISION"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73220	17041-10001-04590	20209 W RINALDI ST BLDG A1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Closed	03/16/2021 12:00:00 AM	ADDRESS	34.27509	-118.57388	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 3. CHANGES INCLUDE ADDING SITE LIGHTING, REPLACING EXTERIOR LIGHTS, AND REVISING PANEL SCHEDULES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73221	16041-20000-14705	13321 W HARDING ST	91340	7	222B157   663	2513011026	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	PIN	34.30091114	-118.42421642	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73222	15041-20000-17999	18221 W MARILLA ST	91325	12	201B125   248	2764018017	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.24742	-118.53054	Installation of new roof mounted solar PV array.  Total area = 6.5 kWac.  Microinverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73223	16041-20000-36126	6612 N NESTLE AVE	91335	3	180B125   410	2125019009	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			10/12/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.19076	-118.53066	Plan check for the addition of a PV1 roof-mounted PV system to an existing PV system. System addition size is 3 kWac and consists of (1) inverter, (9) modules, and (1) load center. Total system size is 6.8 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73224	18041-20003-02539	6927 N REMMET AVE unit b	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			11/20/2018 12:00:00 AM			PC Approved	11/20/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	11/20/2018 Changes to an approved set of plans.  Plans updated to match proposed service configuration under separate permit. 08/02/2018 Changes to an approved set of plans. Plans updated to match revised service configuration.*****Previous Work Description*****pv2install roof mounted pv system sized 5kw interconnected with msp to unit B.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73225	17041-10001-04116	310 N CARMELINA AVE	90049	11	135B141   814	4405003001	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES  (STANDARD ST)	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM			PC Approved	07/26/2017 12:00:00 AM	ADDRESS	34.06215	-118.48478	07-14-2017 Plan check for lost set of plans. {{{{NEW SFD WITH ATTACHED GARAGE. PC FOR POWER AND RESIDENTIAL ENERGY STANDARDS. PC IN ACCORDANCE WITH 2014 STANDARDS DUE TO BUILDING SUBMITTAL. THIS APPLICATION IS PLAN CHECK ONLY. COMBO PERMIT AND ELECTRICAL FEES ALREADY ISSUED UNDER BUILDING PERMIT.}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73226	10041-20001-23167	15823 W MONTE ST #104-106	91342	7	225B141  1524	2604003***	[Q]MR1-1VL	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Closed	05/19/2011 12:00:00 AM	ADDRESS	34.31094	-118.47588	REVISION ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73227	14041-10000-32930	9320 N GLENOAKS BLVD	91352	6	198B173    53	2538011009	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.23797	-118.37472	Plan check T-24 only for T.I.  replacing existing high beam fixture with LED lamps and wire is to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73228	19041-20000-47476	961 S WELLESLEY AVE	90049	11	126B141    77	4264021018	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.04502	-118.47309	PV1. INSTALL 10.69 KW DC PV SYSTEM WITH (31) MODULES AND MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73229	17041-10000-04483	1027 W E ST BLDG 5	90744	15	030B201   837	7417012925	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM				Plan check for new fire alarm system appartment building. Total fire alarm devices 34 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73230	15041-20000-37225	16916 W LORNE ST	91406	6	189B133   226	2204030008	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.2171	-118.50187	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(22) SUNEDISON F325 Modules(22) P400 Power Optimizers(1) SE6000A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73231	10041-10000-13152	17051 W VENTURA BLVD	91316	5	168B133    35	2258013012	C4-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			07/09/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	ADDRESS	34.16037	-118.50502	TI in an existing pharmacy. Plan Check is for Title 24 Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73232	15041-20000-40211	11962 W GORHAM AVE 1-4	90049	11	129B145   502	4265020011	[T][Q]RD1.5-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			11/30/2015 12:00:00 AM			Reviewed by Supervisor	12/08/2015 12:00:00 AM	ADDRESS	34.05014	-118.47056	Plan check for power only. Upgrade existing 400A service to 600A service for 4-unit condo building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73233	19041-10000-30778	4959 W LEMON GROVE AVE	90029	13	141B193   107	5535032900	OS-1XL	Central	Hollywood	Hollywood Studio District		1916.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.08636	-118.30489	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73234	17041-10000-13305	1930 W WILSHIRE BLVD 14th floor	90057	1	132A203    41	5142002019	C4-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.05713	-118.27464	FIRE ALARM T.I. REPLACE (1) CONTROL PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73235	18041-20000-00404	2426 E WASHINGTON BLVD SHOP	90021	14	118-5A217 128	5168012020	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/04/2018 12:00:00 AM			PC Info Complete	04/25/2018 12:00:00 AM	ADDRESS	34.01867	-118.22934	TI to (E) shop building.  New 800A 240/120V 3ph-4w service supplying two separate buildings plus site.  Permit for separate office building under 18041-20000-00401.    Building permit for 2-story office under 18016-20000-00230.Building permit for shop under 18016-20000-00264.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73236	13041-10001-34428	3448 W FERNCROFT ROAD	90039	13	153A207   218	5437022009	R1-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2013 12:00:00 AM			Corrections Issued	02/20/2014 12:00:00 AM	ADDRESS	34.11319	-118.26351	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER NON STD PLAN. SYSTEM SIZE : 3.65 KW .(17) SHARP PV ND 250QCS(17) ENPHASE M215	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73237	15041-20000-21191	2120 E MICHIGAN AVE	90033	14	129A223   381	5183006009	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/27/2015 12:00:00 AM	ADDRESS	34.04625	-118.21196	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73238	18041-20000-06919	20428 W CALIFA ST	91367	3	174B109   109	2151015028	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2018 12:00:00 AM			PC Info Complete	03/06/2018 12:00:00 AM	ADDRESS	34.1763	-118.57842	Final fee = $0.00 due to senate bill 12222pv1install roof mounted pv system sized 15.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73239	10041-10000-20763	3233 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035012	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.00	Electrical	Electrical	Commercial			10/19/2010 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	08/03/2011 12:00:00 AM	ADDRESS	34.02889	-118.37311	TENANT IMPROVEMENT OF (E) ONE STORY MANUFACTURING BUILDING -	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73240	11041-20002-26912	5651 N SEPULVEDA BLVD	91411	4	174B145   321	2243002017	CM-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.17358	-118.46646	"Change to approved plans.  Decrease panel sizes and  Generator from 600amp to 400 amp.  No change to any loads, no additional circuits or equipment.  PLAN CHECK ONLY FOR ""DELTA 7"" Changes.     <<<New 3-story medical and office building with surgery rooms.  New 2,500A service, sub panels, emergency generator, circuits and lighting.  Full plan check.>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73241	19041-10000-27483	15339 W SATICOY ST	91406	6	186B145    35	2222013050	RA-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.20861	-118.46754	remove HID fixtures and replace with new LED fixtures (Indoor and Outdoor )- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73242	14041-10000-30735	3246 W SLAUSON AVE	90043	8	105B185  1434	4005005032	P-1, [Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			11/05/2014 12:00:00 AM			PC Approved	11/17/2014 12:00:00 AM	ADDRESS	33.98753	-118.32913	CHANGE OF USE OF TENANT SPACE FROM RETAIL TO OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73243	14041-10000-00976	15858 W OSBORNE ST	91343	12	195B141   168	2672014032	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.23367	-118.4783	PV1, Install 5.5 kW DC roof-mounted solar array, interconnect with existing service panel. (1)Transformerless inverter(s): Solaredge SE5000A-US. (22) modules Rensola Solar Modules JC250M-24/BB with (2) Strings of 11 modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73244	14041-20000-01961	14620 W SUTTON ST	91403	4	165A149    87	2276028039	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1413.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	08/07/2014 12:00:00 AM	ADDRESS	34.14755	-118.45313	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73245	17041-20001-29099	9516 N ORION AVE	91343	7	198B145    24	2656012025	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	34.24325	-118.47176	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.8 kWac and consists of (2) inverters, (45) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73246	14041-10000-08294	2278 W 29TH ST	90018	10	120B189    66	5052020012	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Expired	09/02/2016 12:00:00 AM	ADDRESS	34.02896	-118.31708	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM STANDARD PLAN. 3.0KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73247	18041-20001-25635	18460 W ROSCOE BLVD	91325	12	192B125   934	2102001018	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM			PC Approved	04/16/2019 12:00:00 AM	ADDRESS	34.22046	-118.53569	PLAN CHECK ONLY SUPPLEMENTAL CHANGES TO APPROVED SET. CHANGING ALL THE LIGHT FIXTURE MODELS, CHANGES TO TITLE 24 TOTAL SQUARE FOOTAGE TO 17,774 SF, CHANGES TO LIGHT FIXTURE SCHEDULE, CHANGES TO T24 SHEET. ALSO CHANGES TO FLOOR PLANS FOR CHANGES TO LIGHT FIXTURES AND CHANGES TO PHOTOMETRICS. ALL DELTA 2 CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73248	19041-10000-23569	7301 N COLDWATER CANYON AVE	91605	2	186B161   568	2327016007	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Issued	06/20/2019 12:00:00 AM	ADDRESS	34.20307	-118.41396	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73249	17041-20000-09370	2828 N NEWELL ST	90039	13	148-5A213 150	5442017040	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	10/17/2017 12:00:00 AM	ADDRESS	34.10192	-118.24324	core and shell to an existing building.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73250	18041-10000-04281	9900 S VERMONT AVE	90044	8	091-5A199  71	6054008030	C2-1VL, P-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2404.02	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	03/05/2018 12:00:00 AM	ADDRESS	33.94607	-118.29138	PC for T24 only for replacement of metal halide fixtures with new LED fixtures in outdoor areas. Total area 47070sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73251	18041-20000-06309	11757 W SAN VICENTE BLVD	90049	11	129B145    16	4401017007	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.05338	-118.4679	Core and shell for 1st floor retail/cafe space, 2nd floor office.  Plan check for energy.   (E) 400A service.Building permit 18016-10000-03528	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73252	16041-20000-34098	1060 S BRONSON AVE	90019	10	129B189   227	5081005023	R3-1-O-HPOZ	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			09/26/2016 12:00:00 AM	04/09/2018 12:00:00 AM		Permit Finaled	06/29/2021 12:00:00 AM	ADDRESS	34.05262	-118.32256	Plan check for power only. Project site is a new 3-story, 10-unit apartment building. Work includes an 800-amp service.Note: Building application has been generated under 16010-20000-04094	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73253	17041-10000-39143	1320 S CONCORD ST	90023	14	118-5A225 215	5190021900	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/30/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.02044	-118.20791	PC for FA system for modular school building. Installing 29 devices, one FACP and one annunciator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73254	12041-10000-04223	20360 W DELITA DR	91364	3	171B109   313	2166037024	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.16259	-118.57794	50 solar modules on SFD roof.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73255	18041-10000-22758	653 1/2 E MILWOOD AVE	90291	11	108B145   951	4241005024	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM	07/18/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	PIN	33.99226654	-118.46398708	Plan check for a PV1 5.2KW roof mounted system with (16) modules and (1) 5.2KW inverter interconnecting through a new load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73256	17041-10000-29457	22808 S LOCKNESS AVE	90501	15	045B193   407	7347017046	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	33.8187	-118.30644	PC for T24 energy only, replace indoor and outdoor existing fixtures with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73257	16041-20000-11545	3620 S VERMONT AVE B160	90089	9	120B197   929	5039002030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.02213	-118.29133	Plan check for Title 24 only. Project site is an existing classroom within an existing building. Project scope is a tenant improvement. Total lighting area = 1,085 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73258	15041-10001-30002	3010 S FIGUEROA ST	90007	9	120A203    40	5123020024	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Approved	12/16/2015 12:00:00 AM	ADDRESS	34.02461	-118.27803	Changed to approved set. Additional lighting added. Changes clouded delta 2. (((T-24. PC FOR ENERGY ONLY. TI ON EXISTING COMMERCIAL BUILDING (ONO HAWAIIAN BBQ).  SCOPE INCLUDES NEW LIGHTING, AND TWO NEW PANELS. TOTAL AREA IS 2025 SQ. FT. ))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73259	12041-20001-18472	5257 N VINELAND AVE	91601	2	171B173   398	2350014016	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			11/02/2012 12:00:00 AM			PC Approved	11/10/2012 12:00:00 AM	PIN	34.16624794	-118.37063493	First time tenant, Supplemental application for Required Full Plan Check.  Plan check for T-24 is under main application.  ((Approved set for T-24 is included and must be returned to applicant.))<<<<T.I. to existing buiilding.  Install general/emergency lighting.  Plan check for energy only.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73260	19041-10001-31625	110 E 9TH ST 6TH FL	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM			PC Approved	10/10/2019 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLAN CHECK ONLY. CHANGES TO APPROVED SET TO REMOVE ALL TRACK LIGHTING AND UPDATE POWER FLOOR PLANS. T-24 AND PANELS SCHEDULES ARE UPDATED ACCORDINGLY. ALL CHANGES ARE CLOUDED UNDER DELTAS 1 AND 2. (((( Energy plan check for a partial office T.I located on the 6th floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 15,814-SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73261	14041-10003-07484	6321 W HOLLYWOOD BLVD	90028	13	148-5A187 150	5546004013	[Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			02/23/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.10178	-118.32754	Change to approved set by replacing a MSB Swithboard (400-Amp) . All changes on this application are under delta-4 only. Additional permit fee also added from the difference between original application (1000 and 1001)(((PLANCHECK FOR POWER AND ENERGY. Changes made: addition of new service 800A instead of using (E) 400A. (E) 400A switchboard is used as distribution board. Addition of 150kva transformer.  Relocated loads. Panel NN2 and MM2 are new.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73262	18041-30000-32834	252 S RAMPART BLVD	90057	13	136-5A203 304	5155025900	R4-1	Central	Westlake	Greater Echo Park Elysian	YES	2086.20	Electrical	Electrical	Apartment			08/28/2018 12:00:00 AM	08/28/2018 12:00:00 AM		Permit Finaled	11/04/2020 12:00:00 AM	ADDRESS	34.067	-118.27813	NEW FIRE ALARM SYSTEMS FOR  6-STORY 23-UNIT RESIDENTIAL / APARTMENT BLDG WITH ATTACHED GARAGE. (1) FACP, (86) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73263	16041-10000-45539	5842 W CARLTON WAY	90028	13	148-5A191 256	5545010004	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			12/29/2016 12:00:00 AM	12/29/2016 12:00:00 AM		Permit Closed	11/27/2019 12:00:00 AM	ADDRESS	34.10034	-118.31725	Insatallation of new fire alarm system for a 5-story commercial building with 2  subtranian parking levels. Scope includes 129 FA devices and 3 FA panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73264	18041-10000-02578	24213 W VANOWEN ST	91307	12	183B089   634	2034027035	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.19451	-118.65228	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 21 AC MODULES WITH NEW LOAD CENTER. SYSTEM SIZE 7.56KW AC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73265	18041-20000-16560	7600 N BALBOA BLVD #205	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Issued	05/08/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	Plan check for first time tenant retail space new lighting and receptacle. Total area: 1,314 sq ft.B#18016-10000-13841	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73266	14041-10000-33670	2900 W SLAUSON AVE	90043	8	108B189  1419	4005013033	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			12/04/2014 12:00:00 AM			PC Approved	12/17/2014 12:00:00 AM	ADDRESS	33.98888	-118.32466	Conversion of preschool into recreation hall accessory to school.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73267	18041-10000-11476	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			03/29/2018 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	03/20/2021 12:00:00 AM	ADDRESS	34.06259	-118.35341	METHANE MITIGATION SYSTEM (LEVEL 5) . SCOPE INCLUDES 21 SENSORS AND 8 ADDITIONAL DEVICES LOCATED ON THE LOWEST LEVEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73268	19041-20000-37360	5232 E ALHAMBRA AVE	90032	14	138A235    36	5217019021	MR1-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2016.02	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	11/28/2023 12:00:00 AM		Permit Finaled	04/05/2024 12:00:00 AM	ADDRESS	34.07414	-118.17142	CHANGE OF USE FROM EXISTING WAREHOUSE TO NURSERY/ MANUFACTURING PROVIDE NEW PANEL, EQUIPMENTS, AND LIGHTS. TOTAL AFFECTED AREA 5,255 SQFT.B#19016-10000-28097	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73269	18041-20000-37792	318 N WILTON PL 1-5	90004	4	138B193   322	5522033025	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Commercial			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.0768	-118.31338	new fire alarm system 44 devices and facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73270	18041-10000-08358	12351 W ROSCOE BLVD	91352	6	192B165   443	2633001001	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2018 12:00:00 AM	03/07/2018 12:00:00 AM		Issued	03/07/2018 12:00:00 AM	ADDRESS	34.22182	-118.40251	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 10.56KWAC/12.76KWDCSCOPE INCLUDE  44 MODULES WITH MICROINVERTERS AND COMBINER BOX.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73271	15041-10000-14033	770 S GRAND AVE	90014	14	129A209   223	5144012058	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	10/19/2015 12:00:00 AM	ADDRESS	34.04594	-118.25757	NEW FIRE ALARM SYSTEM TO GROCERY STORE (WHOLE FOODS MARKET) FIRST TIME T.I. . SCOPE INCLUDES (1) FIRE ALARM PANEL, (2) POWER SUPPLIES AND  (50)  FIRE ALARM DEVICES .NOTE. THE BUILDING IS NOT A HIGH RISE PER BUILDING PLAN CHECKER CATHERINE NUEZCA GABE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73272	11041-20002-26788	2670 N GRIFFIN AVE	90031	1	139-5A223  15	5206010039	RD3-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	34.07841	-118.21167	Changes to approved set of plans. Addition of panel BB and associated loads.Changing one 400 amp OCPD to two 200 amp OCPD.  Work is on pages E2 and E10.  PLAN CHECK ONLY.      <<<<<Tenant improvement on 3 story commercial bldg, lighting power, title 24, fire alarm under separate application.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73273	14041-20000-01478	23001 W BLYTHE ST	91304	12	189B097   589	2014027019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.21431	-118.62795	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. WITH POWER OPTMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73274	15041-20000-10823	6535 N LANGDON AVE	91406	6	180B145   442	2234019003	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM	05/22/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.18983	-118.4694	Plan check for a PV1 roof-mounted PV system. System size is 4.75 kWac and consists of (19) modules, (19) micro-inverters, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73275	15041-10000-28782	5715 S DENKER AVE	90062	8	108B193  1152	5003030036	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	33.99012	-118.3046	PV1 for a Residential site. Roof mounted solar system: (22) modules, (1) inverter 3.0 kw (1) load center: 125 amps.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73276	10041-20000-25556	150 N LARCHMONT BLVD	90004	4	138B189   734	5515024001	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/27/2010 12:00:00 AM			PC Info Complete	04/07/2011 12:00:00 AM	ADDRESS	34.07452	-118.32343	Plan check and energy for new 2-story commercial building remodel. 600A service upgrade, new panels, new ckts, and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73277	17041-10000-19110	20700 W SESNON BLVD	91326	12	219B109     5	2701001047	OS-1XL, [T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.02	Electrical	Electrical	Commercial			06/26/2017 12:00:00 AM	10/25/2017 12:00:00 AM		Permit Finaled	02/13/2024 12:00:00 AM	ADDRESS	34.29545	-118.58467	Title 24 plan check.  Installation of private tract site lighting in new development.  Lighting area = 367,026 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73278	13041-10000-14031	212 W 7TH ST	90014	14	127-5A211  78	5144015033	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			Permit Closed	02/10/2017 12:00:00 AM	ADDRESS	34.04468	-118.25286	T.I. to existing high rise building on ground floor, Suite #102.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73279	15041-10001-07764	12655 W JEFFERSON BLVD	90066	11	102B161    13	4211005019	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM			PC Approved	01/28/2016 12:00:00 AM	ADDRESS	33.97916	-118.41469	CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED DELTA 3 REVISIONS. ADDITION OF DUCT DETECTORS IN SYSTEM. ORIGINAL PERMIT ISSUED FOR MORE THEN INSTALLED DEVICES. NO PERMIT OFF THIS APPLICATION. PC FOR NEW BATTERY CALC AND CIRCUIT WIRING. PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73280	16041-10001-21962	18433 W ROSCOE BLVD #203	91325	4	192B125   578	2786022035	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM			PC Approved	08/04/2016 12:00:00 AM	ADDRESS	34.22091	-118.53469	8/4/16: Revision to approved plan, noted under Delta-2. Revise light fixture schedule and T-24 form.This is plan check only,  permit was issued under  16041-20000-21962 (master) <<PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR MEDICAL OFFICE. SUITE 203>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73281	12041-10000-26883	1720 N DILLON ST	90026	13	145-5A205 399	5431033021	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2012 12:00:00 AM			Reviewed by Supervisor	11/21/2012 12:00:00 AM	ADDRESS	34.0914	-118.27089	2.34 kw roof mounted PV for a single family using X-formerless INV. (PV1)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73282	12041-10000-02188	10250 W SANTA MONICA BLVD #58	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/30/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to an existing retail store.  New lighting and recptacles.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73283	14041-10000-30557	1099 N GRAND AVE	90015	14	127-5A207 265	5139008001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Expired	12/13/2016 12:00:00 AM	PIN	34.04197664	-118.26208092	Temp power for existing building renovation.  Plan check for power.  Initial permit filed under 14041-10000-28931.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73284	15041-10001-12267	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM			PC Approved	12/02/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	CHANGES TO APPROVED SET OF PLANS. SET CONTROLLED RECEPTACLES TO LOCAL TIME CLOCK. LIGHITNG CONTROLLED THROUGH OCCUPANCY SENSORS, NO ROOM CONTROLLER. NO OTHER CHANGES. POWER DENSITY REMAINS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73285	16041-20001-32843	2543 S AMHERST AVE	90064	11	120B149   396	4257023046	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2713.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2017 12:00:00 AM			PC Approved	09/20/2017 12:00:00 AM	ADDRESS	34.02552	-118.4485	9.20.2017 - Plan check for changes to approved set (to reflect as built conditions). Remove Tesla Powerwall from system - only change.======BATTERY STORAGE SYSTEM + PV1 ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73286	19041-20000-51987	15549 W AQUA VERDE DR	90077	5	156B141    78	4378032010	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.12242	-118.47355	Plan check for PV roof mounted system, PV system size: 9.36KW DC, with 26 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73287	14041-10000-02364	881 W MIRAFLORES AVE	90731	15	021B197   551	7447020026	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	33.75272	-118.29635	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH 200A MAIN SERVICE. SYSTEM SIZE IS 2.5 kW DC. (10) TRINA # TSM-250PA05.18 MODULES, (10) OPTIMIZERS OP300-MV, (1) SE3000 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73288	19041-20000-44027	7435 N LENA AVE	91307	12	186B097   598	2021010014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.20532	-118.62672	PV1.  Installation of 2.48 kW DC roof mounted grid tied PV system addition to (E) 1.00 kW DC rated PV system - total system size of 3.48 kW DC.  (8) new modules with microinverters in series with (E) string of 4 modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73289	17041-10001-39097	205 N LAKE SHORE TER	90026	13	135A207   195	5159017009	R3-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.06457	-118.26115	Supplemental for update in word description:PC for 3.8kW roofmounted solar PV. Installing 11 modules with 3.8kW central inverter.zero fees due to senate bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73290	18041-20000-27334	13846 W MOORPARK ST	91423	4	165B153   368	2271016079	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	Apartment			07/20/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Finaled	05/12/2024 12:00:00 AM	ADDRESS	34.15016	-118.43484	Plan check for Title 24 only in appartment common area. Total area; 4147 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73291	19041-10000-19520	719 S HOOVER ST	90005	1	133-5A201 207	5077015017	C2-1	Central	Wilshire	MacArthur Park		2122.04	Electrical	Electrical	Apartment			05/23/2019 12:00:00 AM	02/14/2023 12:00:00 AM		Issued	02/14/2023 12:00:00 AM	ADDRESS	34.05918	-118.28435	Full Plan check for a new 1200-Amp 3-phase 4-2ire 120/208V service feediing a new 1000A distribution board that feeds various subpanels (dwellining units) the  total area is  19,293-SQ FT. BUILDING PERMIT IS UNDER 19010-10000-00921	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73292	13041-10001-27868	5017 W AMBROSE AVE	90027	4	150B197   307	5589011025	RE9-1	Central	Hollywood	Greater Griffith Park		1893.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM			PC Approved	10/25/2013 12:00:00 AM	ADDRESS	34.10894	-118.29864	"][][]EXPEDITED PER APPLICANT REQUEST][[]][[][]PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(12)modules: {Trina {TSM-250PA05.08}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}] . 1"" CONDUIT IN TRENCHED.  NEW 125A LOAD CENTER IS ADDED."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73293	11041-10000-11922	415 N MISSION ROAD	90033	14	130-5A219  46	5410006008	[Q]M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.20	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	06/09/2011 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.05361	-118.22654	Per Inspector's request:  Title 24 plan check for restrooms.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73294	19041-10000-49953	1709 W 8TH ST	90017	1	130-5A205  64	5142014044	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			12/05/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.0531	-118.27354	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73295	10041-20001-13338	8240-8244 N VAN NUYS BLVD	91402	6	192B149   446	2212004033	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			08/16/2010 12:00:00 AM			PC Approved	08/16/2010 12:00:00 AM	ADDRESS	34.22092	-118.44858	Revision to T-24 Energy (general/emergency) lighting calculation for #8240 -8244 (restroom) only. Lighting fixtures in #8226 existing to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73296	16041-20000-44885	20100 S VERMONT AVE	90502	15	054B197     9	7351033031	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	03/17/2017 12:00:00 AM	ADDRESS	33.84826	-118.29025	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 680 sq. ft.Note: Building permit has been pulled under 16016-20000-27236	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73297	14041-20001-17118	19712 W ANADALE DR	91356	3	162B117   203	2180013009	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2014 12:00:00 AM			PC Approved	07/08/2014 12:00:00 AM	ADDRESS	34.14093	-118.56269	Expedite per customer request8.4KW PV1roof-mounted system with (30) Sunmodule Plus SW280 modules and Enphase M250 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73298	17041-20000-28663	6853 N LANKERSHIM BLVD	91605	2	183B169   491	2321018024	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.19542	-118.38812	Plan check for energy only. TI - change of use from warehouse to retail. New lighting (incl. emergency): indoor-2,351sqft; outdoor-4,857sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73299	11041-20000-11458	2819 S VERMONT AVE	90007	8	120B197    62	5054033014	C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2218.10	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	09/21/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	ADDRESS	34.02898	-118.2917	T.I. to existing space.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73300	19041-10000-20507	14431 W BURBANK BLVD	91401	4	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.17235	-118.44762	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73301	18041-20000-31363	700 S FLOWER ST Suite 820	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	08/20/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is suite in a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 3,935 sq. ft.Note: Building application has been generated under 18016-30000-23827	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73302	18041-20000-08878	611 N WESTERN AVE	90004	4	141B193   838	5522010019	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1924.20	Electrical	Electrical	Commercial			03/12/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.08203	-118.30929	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from office to commercial kitchens. Work includes an 800-amp service and a total lighting area of 11,661 sq. ft.Note: Building permit issued under 18016-20000-06657.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73303	18041-10000-18947	777 S SANTA FE AVE 1ST-FLOOR	90021	14	124-5A217 361	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/23/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	03/11/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	Full plan check for a change of use for an office T.I located in the 1st floor of a (2) story building with same servcie supplying the whole building. Scope includes new lighting and equipment. Total area is 39,992 SQ FT. Note. 2nd floor is under serparated permit with office T.I. under a different phase.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73304	16041-20001-09634	6126 E CRESTWOOD WAY	90042	14	159A231   119	5481002023	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM			PC Approved	03/31/2016 12:00:00 AM	ADDRESS	34.131	-118.1877	03/31/2016 Changes to an approved set of plans. PV modules has changed from a Solar World SW250 to a Hyundai M260.*****Previous Work Description*****PV1.  Install 2.0 kW DC roof-mounted PV system.  Microinverter standard plan.  (8) modules with Enphase M215 microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73305	19041-10000-44046	7026 N FALLBROOK AVE	91307	12	183B097   352	2024020012	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.19831	-118.62316	NEW ROOF-MOUNTED PV1 INSTALLATION WITH A SERVICE OF 225 AMPS. INSTALLATION INCLUDES 20 MODULES (LG320N1K-A5), 1 INVERTER (SE5000H-US), & 20 OPTIMIZERS (P320). SYSTEM SIZE: 6.4 KW DC; 5 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73306	14041-20001-09213	11916 N DUNNICLIFFE CT	91326	12	216B125   177	2870021026	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2014 12:00:00 AM			PC Approved	04/24/2014 12:00:00 AM	ADDRESS	34.28811	-118.53668	EXPEDITE FEE ONLY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73307	18041-10001-24269	461 N ROBINWOOD DR	90049	11	135B141   282	4494016009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			06/28/2018 12:00:00 AM			PC Approved	04/09/2019 12:00:00 AM	ADDRESS	34.06739	-118.48301	EXPEDITE PER APPLICANT REQUEST. (((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.16KWdc / 11.04KWac. (48)MODULES-SOLARWORLD SW295MONO(48) MICROINVERTERS- ENPHASE IQ6-60-X-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73308	15041-20000-02002	2011 E ZONAL AVE Bld. HMR	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/29/2015 12:00:00 AM	07/22/2016 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.06159	-118.20463	Plan check for the permanent power to replace the 4.8KV service with 12.4KV to supply the existing USC HMR building.  Replace transformers and switchgears.  No change in connected load.  Plan check for power only.  Note: Variance will be submitted for the single entrance to electrical room.Note: Temporary power is submitted under 14041-20000-26991.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73309	14041-20000-30725	7948 N FALLBROOK AVE	91304	12	189B097   485	2013026003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	01/09/2015 12:00:00 AM	ADDRESS	34.215	-118.62317	PV1INSTALL ROOF MOUNTED PV SYSTEM  SIZED 5.0KW INTERCONNECTED WITH MSP.(24) CANADIAN SOLAR MODULES 250P WITH POWER OPTIMIZERS(1) SOLAREDGE 5.0KW TRANSFORMERLESS INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73310	15041-20000-13959	1801 W OLYMPIC BLVD 1st floor	90006	1	130-5A203 277	5136009024	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	09/23/2015 12:00:00 AM	ADDRESS	34.05046	-118.27663	Plan check for energy only. TI to an existing office on the first floor. New lighting (incl. emergency) and receptacles 1,294sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73311	15041-10000-14176	380 WORLD WAY T-85	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/11/2015 12:00:00 AM	05/11/2015 12:00:00 AM		Permit Finaled	05/22/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	INSTALL L 7 ELEVEN LED SINAGE NOT VISIBLE FROM ROW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73312	11041-10001-22762	5150 W WILSHIRE BLVD 2nd floor	90036	4	132B181    35	5507025021	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			12/09/2011 12:00:00 AM			PC Approved	12/09/2011 12:00:00 AM	ADDRESS	34.06202	-118.3421	Revision to approved plan T24 Energy plan only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73313	19041-10000-24666	100 S GRAND AVE Podium	90012	14	132A211    94	5149021***	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2074.00	Electrical	Electrical	Commercial			07/10/2019 12:00:00 AM	01/15/2020 12:00:00 AM		Issued	01/15/2020 12:00:00 AM	ADDRESS	34.05536	-118.24876	Full plan check for a brand new 6-story podium sharing a common parking at lower floor/underground with two other buildings (a 24-story 308-hotel unit  buidling (Tower # 1) and a 42-story 436-unit  residential building (Tower #2)). Scope of the podium includes a medium voltage 5kv 1200A service suppling the mix-use retails and parking lot. Note Tower# 1 and Tower #2  buildings will be under a seperated applications.  Most of  title-24 energy calculation is under the application of podium building. All 3 application is under 1 set of plan.Related building application including: 17010-10000-01468                                                                       17010-10008-01468  (((PROPOSED MIXED USE HIGHRISE BUILDING CONSISTING OF 2 TOWERS OVER PARKING. 20 STORY HOTEL AND A 39 STORY APARTMENT BUILDING WHICH INCLUDES  **** AFFORDABLE UNITS. THE COMMERCIAL SPACES WILL BE APPROVED AS A CORE AND SHELL, THE HOTEL ROOMS WILL BE REVIEWED AND APPROVED UNDER THE 10008 PERMIT. THE TENANT IMPROVEMENTS TO BE APPROVED UNDER SEPARATE PLAN CHECK/PERMIT.STEEL STAIRS AND RAILS, CURTAIN WALLS- ALL DOORS AND WINDOWS/STORE FRONTS, GLASS COVERED STRUCTURES ARE DEFERRED STRUCTURALLYVERIFY THAT THE SUSMP CLEARANCE OBTAINED)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73314	13041-20003-34372	6500 W SELMA AVE	90028	13	148-5A187 328	5547017001	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM			PC Approved	11/19/2015 12:00:00 AM	ADDRESS	34.09966	-118.33121	11.19.2015 - Plan check for changes to approved set. All delta 4 changes, including: Add Gym area (canvas and associated lights/receptacles) on roof and new panel GR. Add lights to exit stairwell. Add inverter to supply exhaust fan. Reduce planter receptacles on roof. Add two A fixtures to interior stairwells. Rearrange mechanical room.*****Previous Work Description*****07/23/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 3. Changes to the roof power and lighting. All changes have been reflected onto the Title 24 Compliance Forms.*****Previous Work Description*****[[[[10/22/14  CHANGES TO APPROVED SET. DELTA 2 CHANGES ONLY. CHANGES TO INDOOR LIGHTING PLUS INCLUSION OF MEZZANINE IN T24.]]]]POWER AND ENERGY FOR LOWRISE HOTEL WITH 2000A SERVICE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73315	15041-20000-16400	3224 S PURDUE AVE	90066	11	120B157   855	4250023005	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.02198	-118.43045	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (2) inverters, (20) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73316	15041-10000-08574	16650 W SHERMAN WAY	91406	6	183B137    70	2225005014	[Q]CR-1, [Q]CR-1VL, [Q]P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM	03/25/2015 12:00:00 AM		Permit Finaled	07/28/2015 12:00:00 AM	ADDRESS	34.2008	-118.49594	NEW FIRE ALARM SYSTEM 104 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73317	14041-20000-31725	8000 N WOODLEY AVE	91406	6	189B141    49	2206005015	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM			Verifications in Progress	03/26/2015 12:00:00 AM	ADDRESS	34.21603	-118.48348	PV2. COMMERCIAL ROOF MOUNTED SOLAR SYSTEM.  NEGATIVELY GROUNDED SYSTEM. SYSTEM SIZE: 492.49 KW DC.(784) LONG SLSM 230P(1007) CANADIAN SOLAR CS6X(8) SOLECTRIA PVI-20TL(9) SOLECTRIA PVI-28TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73318	13041-10000-14849	11920 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Info Complete	06/07/2013 12:00:00 AM	ADDRESS	34.05237	-118.47062	Title 24 energy only for retail space, power is less than 400 amps, San vecinte retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73319	18041-10001-24367	11241 W OTSEGO ST	91601	2	171B173   852	2353003019	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			02/13/2019 12:00:00 AM			PC Approved	02/13/2019 12:00:00 AM	ADDRESS	34.16307	-118.37627	Change to approved set by changing some residential feeders from copper to aluminum. Floor plan and panel schedule of the apartment units also being updated.(((Plan check for power and energy for new apartment building 3 story 42 units Service size: 1600A. Total area: 29,184 sq ft.  B#17010-10000-04951)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73320	14041-10000-13137	1243 S WELLESLEY AVE # 6	90025	11	126B145   494	4267036012	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2014 12:00:00 AM			Reviewed by Supervisor	05/29/2014 12:00:00 AM	ADDRESS	34.0418	-118.46837	PV1, INSTALL 12.50 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZER AND TRANSFORMERLESS INVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73321	18041-20001-09549	24770 W CALVERT ST	91367	3	177B085   143	2032029024	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2018 12:00:00 AM			PC Approved	04/02/2018 12:00:00 AM	ADDRESS	34.18317	-118.66551	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 17.25 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73322	14041-10000-14918	2239 W QUEENSBOROUGH LANE	90049	5	150B141    86	4377046004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	06/27/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.10938	-118.47778	PV1, INSTALL 7.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73323	17041-20000-43847	17516 W LEMARSH ST	91325	12	204B129   281	2734015013	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.25564	-118.51629	pv1install roof mounted pv system sized 7.7kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73324	11041-10000-17113	9301 N TAMPA AVE # 11	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM	10/13/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.2392	-118.55379	remodel existing retail storeplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73325	18041-20000-04511	6224 S FIGUEROA ST	90003	9	105B201  1037	6004038049	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2371.02	Electrical	Electrical	Commercial			02/07/2018 12:00:00 AM	08/23/2018 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	33.98261	-118.28245	Plan check for power and energy. Project site is a new multi-tenant building. Project scope is a core and shell. Work includes a 1,000-amp service and a lighting area of 24,370 sq. ft.Note: Building application has been generated under 17010-20000-04475	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73326	14041-10000-06922	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	PLANCHECK FOR T24 ENERGY. OFFICE ROOM. TOTAL AREA 286 SQ FT. WORK TO BE INDOORS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73327	15041-20000-39143	7409 N WESTCLIFF DR	91304	12	186B089   324	2027044008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	PIN	34.20679065	-118.65240976	PV1, roof mounted solar panel, 3.8kW AC system, added to an (E) PV system 5kW AC(17)modules: #KU2656ZPA(1) inverter: SE3800A-US-ZB-U(1) Load center 125A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73328	14041-10000-26526	500 S CENTRAL AVE	90013	14	126A215    61	5147014005	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	09/25/2014 12:00:00 AM		Permit Finaled	12/02/2014 12:00:00 AM	ADDRESS	34.04092	-118.23969	PC FOR ENERGY T24 ONLY. INTERIOR OFFICE TI. TOTAL AREA 2782 SQ FT.B# 14016-40000-12852	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73329	17041-20002-22306	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Permit Finaled	12/29/2017 12:00:00 AM	ADDRESS	34.05075	-118.45961	10/18/2017 Changes to an approved set of plans. All changes have been marked as Delta 2 and Delta 3. There has been the addition of a new subpanel, new server-room receptacles, and new HVAC units.10/6/2017 Changes to an approved set of plans. changes include revisions to lighintg floor plan and energy calculations. This is plan check only.  *****Previous Work Description*****ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73330	18041-20000-43251	1201 S HOPE ST Ste 124	90015	14	126A207    67	5138026036	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/13/2018 12:00:00 AM			PC Approved	11/13/2018 12:00:00 AM	ADDRESS	34.0408	-118.26471	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a change of use from retail to office. Total lighting area = 1,259 sq. ft.Note: Building application has been generated under 18016-10000-15644	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73331	14041-20001-03438	6733 N YOLANDA AVE	91335	3	180B121   796	2126037052	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.19291	-118.54059	((((EXPEDITE FEES))))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73332	18041-20000-42121	9868 N SUNLAND BLVD	91040	7	201B181   152	2545014006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.24889	-118.34724	Plan check for PV roof mounted system, system size: 16.5kW DC, 17.6KW AC with 55 PV Modules and 2 inverters(7.6kW and 10.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73333	19041-10000-05085	8500 W BEVERLY BLVD SUITE 718	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/12/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC T-24 ONLY TENANT IMPROVEMENT OF AN (E) RETAIL SPACE IN A COVERED MALL.  SCOPE OF WORK 1652SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73334	15041-20000-43776	6719 N GLADE AVE	91303	3	180B101   127	2139007009	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.19253	-118.60826	Plan check for a PV1 roof-mounted PV system. Plan check is for the addition of 3 kWac system onto an existing 3.6 kWac system. New system consists of (1) inverter, (14) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73335	19041-20000-27114	9710 N VANALDEN AVE pv1	91324	12	201B121   368	2762032011	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.24738	-118.54905	pv1install roof mounted pv system 12.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73336	19041-20000-53405	2915 W EXPOSITION PL Unit #5	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM			PC Approved	04/07/2020 12:00:00 AM				NEW ROOF MOUNTED 2.56KW PV SYSTEM WITH 8 @ 320W PANELS AND A CENTRAL INVERTERS ON AN APARTMENT BUILDING FOR UNIT #5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73337	10041-20000-03070	3710 S MCCLINTOCK AVE #105&105A	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/22/2010 12:00:00 AM	04/05/2010 12:00:00 AM		Permit Finaled	05/19/2010 12:00:00 AM	ADDRESS	34.02027	-118.28994	"TI IN AN EXISTING CLASSROOM (#105 & 105A) IN USC IN THE BASEMENT AREA OF ""RTH"" BLDG (RONALD TUTOR HALL OF ENGINEERING BUILDING). PLAN CHECK IS FOR TITLE 24 ENERGY CALCS AND EMERGENCY LIGHTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73338	13041-10000-35923	12746 W JEFFERSON BLVD STE #3160	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	01/13/2015 12:00:00 AM		Issued	01/13/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	NEW CVS PHARMACY. FIRST TIME TENANT TO NEW SHELL BUILDING. NEW 800A. AREA OF WORK IS APPROX. 17,468 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73339	13041-10000-10453	845 S FIGUEROA ST	90017	9	129A207   195	5144022036	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/23/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.04698	-118.26234	TENANT IMPROVEMENT: 1) FIRST FLOOR LOBBY IMPROVEMENT 2) 2-5 FLOOR TENANT IMPROVEMENTS , 3) NEW BATHROOMS ON 1ST TO 5 FLOORS.  GREATER THAN 400 AMPS NEW CONNECTED LOAD.  POWER AND ENERGY PLAN CHECK.SUBMITTAL TOTAL ADJUSTED TO MEET APPLICANT'S CHECK AMOUNT.  NEW GENERAL PURPOSE BRANCH CIRCUITS TO BE CHANGED TO 428 TO AGREE WITH PANEL SCHEDULE (SEE ATTACHED EPC APPLICATION)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73340	10041-20000-22787	7263 W FOOTHILL BLVD	91042	2	202-5A199 261	2568012026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			11/15/2010 12:00:00 AM	11/15/2010 12:00:00 AM		Permit Closed	12/28/2010 12:00:00 AM	ADDRESS	34.24963	-118.29018	ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73341	19041-10000-26222	7083 W HOLLYWOOD BLVD 5TH FLR	90028	13	147B181   148	5548002046	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM			PC Info Complete	09/26/2019 12:00:00 AM	ADDRESS	34.10173	-118.34439	T-24 PLAN CHECK FOR AN OFFICE TI. SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROLS. TOTAL AFFECTED AREA  IS 1506SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73342	16041-20000-14712	20127 W VIA CELLINI	91326	12	219B113    27	2701039016	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM	05/11/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	34.29409	-118.5716	Install a roof-mounted solar array on a SFD. Interconnect with a 300A MSP.System size: 7.6kW. Ungrounded system. (34) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73343	17041-20000-10654	8262 N HAVEN LANE	91325	6	192B133   531	2204001045	(Q)RD3-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			04/03/2017 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	10/06/2017 12:00:00 AM	ADDRESS	34.22096	-118.50725	pv1install roof mounted pv system sized 3.6kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73344	19041-20000-25136	6617 N BEN AVE pv1	91606	2	180B165   354	2322009052	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1232.04	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	08/19/2019 12:00:00 AM	ADDRESS	34.19086	-118.39444	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.4KWdc / 11.2KWac.(35) AC MODULES- SUNPOWE SPR-X22-327-E-AC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73345	18041-20002-32503	8420 N BALBOA BLVD ste 114	91406	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			07/26/2019 12:00:00 AM			PC Approved	07/26/2019 12:00:00 AM	ADDRESS	34.22384	-118.50243	7/26/19changes o an approved set of plans.  changes to reflect field conditions.  this is plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73346	17041-10001-15998	15031 W RINALDI ST	91345	7	213B145    64	2664022028	A2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	01/19/2018 12:00:00 AM	ADDRESS	34.27918	-118.46029	Changes to approved  set. Updating to one required EV charger on panel PPE (clouded delta 2) and removing PV equipment. B# 16010-10000-05607	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73347	16041-20000-44278	8760 N WHITE OAK AVE	91325	12	195B129   340	2768013015	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.23044	-118.51985	permit fee $0.00 by state senate bill no. 1222pv1install roof mounted pv system sized 15.5kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73348	10041-20000-10127	14349 W FRIAR ST 1-18	91401	6	180B149  1015	2240012021	[Q]R3-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			05/27/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	06/28/2011 12:00:00 AM	ADDRESS	34.1858	-118.44606	Plan check power and energy 18 unit apartments, new 800A service. Variance to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73349	13041-10000-33693	1122 S WALL ST STE G	90015	14	124-5A209 125	5145024031	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM			PC Approved	12/04/2013 12:00:00 AM	ADDRESS	34.03582	-118.25452	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING; REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 840 SQ FT. REPLACING 5 TOTAL UNITS. ALL WORK IS FOR INTERIOR RENOVATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73350	17041-20000-00207	4464 N VISTA DEL MONTE AVE	91403	4	168A151   273	2265011015	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Apartment			01/04/2017 12:00:00 AM	01/04/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.15299	-118.44972	Plan check for a fire alarm system for a new 3-story apartment building. System consists of (1) FACP, (1) annunciator, and (45) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73351	17041-20000-10141	920-922 S OLIVE ST	90015	14	127-5A209 175	5139004016	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.04308	-118.25854	new restaurant 400 amp service.  plan check for power and energy.See comments......	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73352	16041-20001-32337	7032 S RAMSGATE PL	90045	11	102B173   397	4103011016	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM			PC Approved	02/09/2018 12:00:00 AM	ADDRESS	33.97338	-118.37312	"02/09/2018 Changes to an approved set of plans. Dryers in units are to be electric. Service load calculations have taken this into account and panel schedules have been revised to remove the ""gas"" label.*****Previous Work Description*****NEW APARTMENT BUILDING 3 STORY 9 UNIT WITH 800 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73353	11041-20000-21621	14006 W RIVERSIDE DR Parking-Lot	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Expired	11/04/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check T24 Energy for outdoor parking lot canopy lighting under PV panels. Permit for new canopy light fixtures on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73354	18041-20000-39533	9346 N EL DORADO AVE pv1	91352	6	198B165    86	2629010015	RA-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.10	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.23908	-118.3965	pv1install roof mounted pv system sized 3.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73355	17041-10001-13405	1129 S SAN PEDRO ST	90015	14	124-5A211 260	5145025011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM			PC Approved	02/16/2018 12:00:00 AM	ADDRESS	34.03457	-118.25289	PC FOR CHANGES TO APPROVED SET UNDER DELTA 3. SCOPE INCLUDES ADDING NEW LIGHTING FIXTURES AND REVISION TO T-24 FORMS. THIS IS PLAN CHECK ONLY. PERMIT PULLED UNDER MASTER. Plan check for power and energy.  T.I. and change of use in building 13 and 14 to commercial kitchen and event space.  New 600 amp service and distribution system.  Total area = 25,260 sq. ft.     Building permit #16016-10000-30193	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73356	10041-20000-23035	20405 W SORRENTO LANE Building-10	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Apartment			11/18/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	10/26/2011 12:00:00 AM	ADDRESS	34.27827	-118.57876	Plan check for new 3-Story, 23-unit Apartment Building (Type B) Building 10. Modification to seperate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73357	19041-20000-49748	6900 W MANCHESTER AVE	90045	11	096B161   690	4122022930	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Commercial			12/04/2019 12:00:00 AM	06/10/2021 12:00:00 AM		Permit Finaled	01/21/2022 12:00:00 AM	ADDRESS	33.95947	-118.41159	T24 PLAN CHECK ENERGY ONLY, LIGHTS AND OUTLETS, TOTAL SQUARE FOOTAGE = 2464 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73358	17041-20001-31105	832 N HANLEY AVE	90049	11	138B137   387	4494009012	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.07315	-118.48689	expeditepv1install roof mounted pv system sized 15.8kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73359	19041-10000-48233	2646 S HILL ST	90007	9	120A205    10	5122001012	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	07/01/2020 12:00:00 AM		Permit Finaled	02/16/2021 12:00:00 AM	ADDRESS	34.02485	-118.27126	FULL PC FOR POWER AND ENERGY IN A COMMERCIAL WAREHOUSE, SCOPE OF WORK INCLUDES A NEW 600A SERVICE (120/240 1P 3W) AND THREE NEW SUBPANELS. TOTAL AFFECTED AREA IS 6738 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73360	19041-10000-52848	15474 W DUOMO VIA	90077	5	156B145   197	4378036019	RE40-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM	04/23/2020 12:00:00 AM		Permit Finaled	05/12/2020 12:00:00 AM	ADDRESS	34.12386	-118.47023	[EPLAN] PLAN CHECK FOR 2 TESLA POWERWALLS AND 4 NEW SUBPANELS.  EXISTING PV1 SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73361	18041-20001-40233	1369 N BOBOLINK PL	90069	4	147B165   492	4392006004	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.09625	-118.39286	Expedited plan check fee.PV1.  Install 15.84 kW DC roof mounted grid tied PV system.  (48) modules with (2) 7.6 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73362	12041-10000-22212	5545 N BALBOA BLVD	91316	12	174B133   648	2255026017	CR-1VLD, P-1VLD	South Valley	Encino - Tarzana	Encino		1390.00	Electrical	Electrical	Public Safety Only			09/18/2012 12:00:00 AM	09/28/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.17129	-118.50136	NEW FIRE ALARM SYSTEM FOR A COLLAGE BLDG.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73363	18041-20000-27292	509 N ROCKINGHAM AVE	90049	11	135B137   502	4406004008	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			07/20/2018 12:00:00 AM			PC Approved	08/21/2018 12:00:00 AM	ADDRESS	34.06438	-118.49056	Plan check for power only. Project site is a new 2-story single-family dwelling with a basement and attached garage. Work includes a 600 Amp, single phase service.Note: Building permit under 16010-30000-01484. Electrical permit fees have been paid under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73364	17041-10000-28776	976 E 55TH ST	90011	9	108B209   893	5103019001	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	ADDRESS	33.99242	-118.25841	PC FOR PV SYSTEM WITH BATTERY STORAGE. PV SYSTEM RATED 3KW AC AND BATTERY UNIT RATED 5.8KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73365	17041-20001-39064	21729 W VANOWEN ST	91303	3	183B105   926	2138006034	(WC)RIVER-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Expired	05/11/2018 12:00:00 AM	ADDRESS	34.19394	-118.60246	PC for changes to approved set. Changind from underground service to overhead service and adding new show window receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73366	11041-20000-18783	11142 W FLEETWOOD ST #10	91352	6	195B173   348	2408026033	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM			PC Approved	09/02/2011 12:00:00 AM	ADDRESS	34.22988	-118.37387	T-24 ONLYexist. permit 11041-20001-16611	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73367	17041-20000-15396	13052 N DRONFIELD AVE	91342	7	222B153    31	2509020002	(Q)R3-1, RA-1	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Apartment			05/09/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	03/18/2019 12:00:00 AM	ADDRESS	34.30805	-118.43722	2-STORY 44-UNIT APARTMENT BUILDING W/ BASEMENT GARAGE.  PLAN CHECK FOR POWER AND ENERGY.  FIRE ALARM VARIANCE FILED 05/09/2017	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73368	14041-10000-32358	6220 N TOPANGA CANYON BLVD Building E	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.1841	-118.60553	Power plan check for new electrical equipment related to outdoor lighting systems for common area of Westfield Topanga outdoor mall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73369	12041-10000-21456	2403 W 4TH ST	90057	1	135A203   203	5154035003	R3-1	Central	Westlake		YES	2088.02	Electrical	Electrical	Apartment			09/25/2012 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.06409	-118.27662	permit will expire within 30 days of issuanceNEW 4-STORIES  39 UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73370	16041-20000-15082	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	33.79072	-118.29449	PV2. ROOFMOUNTED SOLAR SYSTEM ON A CARPORT.  SYSTEM SIZE: 332 KW . LINE SIDE TAP.1024  MODULES BUILDING PERMIT # 16014-20000-01950 , 16010-20000-01727, 16010-20000-01728PLANS HAVE GROUNDMOUNTED SYSTEM AND CARPORT SOLAR ROOFMOUNTED SYSTEM ON SAME PLANS.Note: Fee $0 due to SB1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73371	15041-10000-03529	12820 S FIGUEROA ST	90061	15	081B201   287	6132015064	C2-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			02/05/2015 12:00:00 AM	02/05/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	33.91593	-118.28252	Title 24 plan check only.  Total area = 6,631 sq. ft.Retrofit existing lights to LED with retrofit kits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73372	12041-10000-21857	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/14/2012 12:00:00 AM			PC Approved	09/14/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	Plan check T24 Energy/Emergency lighting for suite #1470 office TI	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73373	14041-10000-17810	1930 S LONG BEACH AVE EAST	90058	9	118-5A213 351	5167013042	M2-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			07/01/2014 12:00:00 AM			Reviewed by Supervisor	08/26/2014 12:00:00 AM	ADDRESS	34.01969	-118.2427	PV2 81.675KWdc. 480V. xmfrLESS/Ungnd. NONstd. ???story. Roofmount. [(3) inverters: {POWERONE TRIO-27.6,27.6,20}]. [(297)modules: {solarworld SunModule SW-275 mono}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73374	10041-20000-19406	11500 W OLYMPIC BLVD 1st floor	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM	10/06/2010 12:00:00 AM		Permit Finaled	10/28/2010 12:00:00 AM	ADDRESS	34.03624	-118.44415	energy plan check 1st floor	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73375	10041-20002-24911	408 S GLESS ST	90033	14	127-5A219 328	5171001907	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Public Safety Only			03/08/2011 12:00:00 AM			PC Approved	03/08/2011 12:00:00 AM	ADDRESS	34.04265	-118.22256		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73376	14041-20002-28000	6616 S 3RD AVE	90043	8	102B189   325	4008003012	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	33.97869	-118.32053	change to approved set of plans. system is now a 7kw acPV1Install roof-mounted solar array on SFD, interconnect with MSP. System size7kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73377	19041-10000-23140	1057 S WESTERN AVE	90006	10	129B193   589	5080006008	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Apartment			06/26/2019 12:00:00 AM			Reviewed by Supervisor	08/07/2019 12:00:00 AM	ADDRESS	34.05108	-118.30926	(fee estimate) PC for upgrading servise to 800A,240/120V, 3phase,4Wire in a 76 Unit Apartment Bulding. Installing panels. (Core & Shell)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73378	12041-20000-16945	5424 N LAUREL CANYON BLVD	91607	2	174B165  1012	2348014055	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			07/20/2012 12:00:00 AM			PC Approved	07/20/2012 12:00:00 AM	ADDRESS	34.16932	-118.3963	Change from coffee shop to take out restaurant.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73379	18041-20000-23236	4961 N MARMOL DR	91364	3	169-5A109  32	2167013004	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Re-Activate Permit	11/07/2019 12:00:00 AM	ADDRESS	34.16023	-118.59041	Plan check for PV roof mounted system, system size: 11.4kW with 40 modules and 1 inverter(11.4kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73380	16041-10000-09022	22139 W CANTLAY ST	91303	3	186B101   961	2023010020	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.03	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Expired	05/08/2018 12:00:00 AM	ADDRESS	34.20209	-118.60946	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 8.58kWdc / 7.095kWac.(33)MODULES-HANWHA Q PRO BFR-G4 (33)MICROINVERTERS-ENPHASE M215-60-2LL-S22	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73381	19041-20000-53857	3630 S OVERLAND AVE	90034	5	120B161  1057	4314010042	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.03	Electrical	Electrical	Apartment			12/31/2019 12:00:00 AM	11/25/2020 12:00:00 AM		Permit Finaled	06/26/2023 12:00:00 AM	ADDRESS	34.02267	-118.40976	Plan check for Power and Energy for 2500A Service. Total area: 56876 sq ft. B#19010-10000-00780*********Building work Description:**************** 74 UNIT, 7 STORY APARTMENT BUILDING WITH GROUND FLOOR COMMERCIAL   8 UNITS TO BE SET ASIDE FOR EXTREMELY LOW INCOME	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73382	19041-10000-30780	1357 E 22ND ST	90011	9	120A211   404	5119004900	OS-1XL	South Los Angeles	Southeast Los Angeles	South Central		2270.10	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	12/13/2019 12:00:00 AM	ADDRESS	34.0209	-118.25159	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73383	19041-10000-30063	1401 N GLENDALE BLVD	90026	13	141A209   300	5419019019	C2-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1956.00	Electrical	Electrical	Commercial			08/02/2019 12:00:00 AM	08/06/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.08009	-118.26041	Outdoor lighting in a parking lot. T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73384	14041-20000-00432	9700 S BELLANCA AVE	90045	11	093B173   520	4125026011	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			01/07/2014 12:00:00 AM			PC Approved	01/07/2014 12:00:00 AM	ADDRESS	33.94834	-118.37979	PLAN CHECK FOR EMERGENCY LIGHTS ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73385	14041-10000-02336	303 N SWEETZER AVE	90048	5	138B173   395	5514009027	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			01/27/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.07643	-118.3702	T24 PART 6 ENERGY FOR 1670 SQ FT GYMNASIUM. SCOPE OF WORK < 400A. PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73386	10041-10000-18055	5908 W AVION DR	90045	11	090B169    37	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/13/2010 12:00:00 AM			PC Approved	09/16/2010 12:00:00 AM	ADDRESS	33.94256	-118.38477	TI in a commercial building. Plan check for T24. (permit was pulled #10041-10001-14305, 10041-10000-14305)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73387	16041-10001-09096	900 W WILSHIRE BLVD 71st FLR	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/28/2016 12:00:00 AM			PC Info Complete	09/29/2016 12:00:00 AM	ADDRESS	34.05001	-118.25963	09/28/2016 Changes to an approved set of plans. All changes are clouded under delta 3. Changes include removing split bus on panels panel, relocating loads, changing lighting type and layout, revising title 24 forms, and adding new receptacles.  (((((((FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT ON THE 71ST FLOOR OF A NEW  73 STORY, MIXED USED HIGH RISE BUILDING. SCOPE INCLUDES TWO NEW PANELS AND LIGHTING FOR A KITCHEN/DINING/RESTUARANT SPACE. TOTAL AFFECTED AREA IS 14,018 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73388	15041-10001-06377	6638 W HOLLYWOOD BLVD	90028	13	148-5A185 136	5547015031	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/05/2015 12:00:00 AM			PC Approved	08/05/2015 12:00:00 AM	ADDRESS	34.10141	-118.33457	ALTERATIONS ON THE 1ST AND 2ND FLOORS OF AN OFFICE BUILDINGPLAN CHK IS FOR TITLE 24(((((((NSTALL NEW 100 AMP PANEL AND INSTALL 3 NEW 2X4 T-BAR FIXTURES(3 LAMP T-8 ENERGY SAVING), REMOVE OLD SURFACE MOUNTED T-BAR FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73389	10041-10000-14624	11411 W ROCHESTER AVE BLDG I	90025	11	129B149   103	4263016030	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Verifications in Progress	09/27/2010 12:00:00 AM	ADDRESS	34.04904	-118.45408	NEW SERVICE, PANELBOARDS, CIRCUITS FOR 15  UNITS APARTMENT BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73390	16041-10001-42994	8327 W 3RD ST	0	5									Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM			PC Approved	01/17/2017 12:00:00 AM				01/17/17Changes to an approved set of plans. All changes are clouded under delta 1. Changes include separately controlling cabinets lights from zone 3 and adding an additional lighting control zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73391	11041-20000-16416	1100 S GLENDON AVE suite#1220	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM	08/04/2011 12:00:00 AM		Permit Finaled	09/13/2011 12:00:00 AM	ADDRESS	34.06074	-118.44418	TI IN AN OFFICE. EPC IS FOR T24 & EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73392	17041-20000-01996	17209 W MINNEHAHA ST	91344	12	207B133  1030	2695013059	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2017 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	PIN	34.26053982	-118.5093695	PV1. ROOFMOUNTED SOLAR SYSTEM. STANDARD PV PLAN. AC MODULES. SYSTEM SIZE: 5.7 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73393	14041-10001-11143	12426 W VERDI ST	90066	11	108B157  1498	4221005077	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2014 12:00:00 AM			PC Approved	05/29/2014 12:00:00 AM	ADDRESS	33.98902	-118.41971	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.WITH OPTIMIZER.(1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE6000A-US-ZB-U(25) MODULES: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73394	19041-20000-02768	1429 S WESTWOOD BLVD	90024	5	132B153   916	4324010009	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Closed	02/13/2023 12:00:00 AM	ADDRESS	34.05467	-118.44147	Plan check for PV roof mounted system, system size: 8.58KW DC, 7.0KW AC with 26 PV Modules and 1 inverter(7.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73395	13041-10000-19319	1411 W 190TH ST SUITE 270	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	33.85852	-118.30317	TENANT IMPROVEMENT in office spacePLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73396	12041-10000-30390	5900 W WILSHIRE BLVD 11 floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM			PC Approved	01/07/2013 12:00:00 AM	ADDRESS	34.06237	-118.35809	T24. TI TO EXISTING OFFICE. HIRISE 11TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73397	16041-10000-27776	1717 W 6TH ST	90017	1	132A205    16	5153004013	C2-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Commercial			08/05/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.05775	-118.27044	Remove outdoor HID fixtures and replace  with new LED fixtures - plan check T/24 only. Total area 6477 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73398	11041-10000-12361	525 S FLOWER ST	90071	9	130-5A209 146	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	07/13/2011 12:00:00 AM		Permit Finaled	11/30/2011 12:00:00 AM	ADDRESS	34.05109	-118.25696	T.I.  Upgrading the existing fire alarm and smoke control for three floor tenant improvement (1st, 2nd, and 3rd floors).  Regular Plan Check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73399	17041-10000-42192	333 S LUCERNE BLVD	90020	4	135B189   298	5505018014	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Issued	01/10/2018 12:00:00 AM	ADDRESS	34.06787	-118.32457	PC for power for two new tesla powerwalls in SFD. Installing two tesla powerwall and 125 panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73400	18041-10000-21806	2601 S FIGUEROA ST Bld #1	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.02804	-118.2763	Fire plan check for an eixising fire alarm system located at the buildig #1 of the same lot of a  multi building structure. All fire alarm system located  in the lot shall interconnced through a same fire alarm system.Total 4 applications under 1 plan including building 1, 4, 5 and 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73401	18041-20001-07346	4108 N KRAFT AVE	91604	2	162B169   204	2368020023	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM			PC Approved	03/06/2018 12:00:00 AM	ADDRESS	34.14276	-118.37992	expeditepv1install roof mounted pv system sized 13.6kw interconnected with msp.  (3) tesla power walls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73402	16041-10000-08991	2750 E 1ST ST	90033	14	126A225     5	5180014011	QC4-1	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	05/12/2017 12:00:00 AM		Permit Finaled	06/02/2017 12:00:00 AM	ADDRESS	34.04146	-118.20521	FULL PC FOR POWER AND ENERGY TO A TI IN A FOOD 4 LESS RETAIL. SCOPE OF WORK INCLUDES NEW LOAD TO EXISTING PANELS, TOTAL CONNECTED LOAD > 400AMPS,  277/480, 2000AMP SERVICE. TOTAL SQ. FT. 49171.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73403	15041-10000-04507	1000 W WILSHIRE BLVD # 2145	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/17/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	04/30/2015 12:00:00 AM	ADDRESS	34.05085	-118.26078	Title 24 plan check only.  Total area = 4,315 sq. ft.T.I. to existing office space.  Lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73404	17041-20001-15615	3813 W RONDA VISTA PL	90027	4	150B201  1138	5433009035	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.10477	-118.27596	Feeder wiring changes and load center bus rating change.(((Installation of four new Tesla AC Powerwall 5.8 kVA battery storage systems.  Interconnect to existing rooftop PV system via new 200 amp load center.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73405	10041-10000-25628	1285 N OAK HILL AVE	90032	14	151-5A233 288	5312021041		East Los Angeles			YES	1837.00	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2010 12:00:00 AM	05/05/2011 12:00:00 AM		Permit Finaled	08/12/2011 12:00:00 AM	PIN	34.10738219	-118.17774685	Photo  voltaic system 11.75 kw DC for a single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73406	19041-10000-20673	2445 E 12TH ST C	90021	14	120A217    96	5168003013	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/31/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	34.02277	-118.22852	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO (E) WAREHOUSE  WITH (N) OFFICES, SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 6967 SQ. FT.  B#19016-10000-11665	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73407	14041-10000-07556	5115 N MAMMOTH AVE	91423	4	171B153   589	2269003027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2014 12:00:00 AM	03/20/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.16361	-118.43254	PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTER STANDARD PLAN. SYSTEM SIZE:1 KW DC.(4) SUN EDISON MEMC M250 MODULES.(4) ENPHASE M215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73408	10041-10000-11782	1200 W 7TH ST	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			06/21/2010 12:00:00 AM	01/05/2011 12:00:00 AM		Permit Finaled	07/05/2011 12:00:00 AM	ADDRESS	34.05136	-118.26616	Ti in the IT room. New distribution board, panels and circuits. EPC for power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73409	14041-10000-30173	11178 W PENROSE ST Suite #3	91352	6	192B173    29	2408022029	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			10/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.22678	-118.37445	Title 24 plan check only.  Total area = 1,164 sq. ft.Replace HID lighting with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73410	14041-20000-32848	12180 W MILLENNIUM 1ST FLR-HR	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	01/14/2015 12:00:00 AM		Permit Finaled	04/01/2015 12:00:00 AM	ADDRESS	33.97975	-118.40731	TI TO AN EXISTING COMMERCIAL HIGH RISE BUILDING.  ADDING NEW LIGHTING AND CIRCUITS TO NEW PANEL.  TOTAL SQUARE FOOTAGE 2870. PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73411	13041-20000-23841	7309 N HILLSVIEW CT	91304	12	186B089   540	2027047008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	09/16/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	PIN	34.20426695	-118.65176836	PV1 TRANSFORMERLESS SYSTEM. 25 MODULES AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73412	15041-20000-21688	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	10/30/2015 12:00:00 AM	ADDRESS	34.06086	-118.27891	TI to existing commercial building. Plan check for energy only. Adding new lighting to basement. Total sqft. 24,843.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73413	16041-10000-05653	1845 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1-1, C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM			PC Info Complete	03/15/2016 12:00:00 AM	ADDRESS	34.04302	-118.37664	TI to an (E) McDonald. Install new lighting fixtures. PC for T-24 only. Total area: 1869sq.ft(indoor) and facade area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73414	17041-20000-14088	6660 W SUNSET BLVD STE G	90028	13	147A185    84	5547023028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			04/28/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.09781	-118.33562	PLACHECK FOR T24 ENERGY. CHANGE OF USE OF A PORTION OF A RETAIL SPACE TO A YOGA STUDIO  ( 1800 sq ft )	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73415	18041-10000-06588	1925 S CENTURY PARK EAST 17TH &18TH-FLOORS	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	03/05/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.06066	-118.41426	TENANT IMPROVEMENTS IN THE RESTROOMS ON THE 17TH & 18TH FLOORSPLAN CHECK S FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73416	19041-20002-07450	12309 W MILBANK ST	91604	2	168B165   986	2364014031	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2019 12:00:00 AM	06/24/2019 12:00:00 AM		Issued	06/24/2019 12:00:00 AM	ADDRESS	34.15326	-118.40116	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CHANGE TO SINGLE LINE, EQUIPMENT DETAIL, SIGNAGE PAGE, AND SITE PLAN. REMOVAL OF TWO AC DISCONNECTS AND ADDING TWO 125A LOAD CENTERS. MINOR CHANGES TO ALL OTHER PAGES. CLOUDED DELTA 1 CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73417	17041-10000-28218	11601 W WILSHIRE BLVD	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM	02/26/2019 12:00:00 AM		Permit Finaled	01/29/2021 12:00:00 AM	ADDRESS	34.05075	-118.45961	FULL PC FOR POWER AND ENERGY FOR EXTERIOR PLAZA AREAS. SCOPE INCLUDES TWO NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 15399 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73418	11041-20000-15678	515 S FLOWER ST #340, 350	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2011 12:00:00 AM	07/26/2011 12:00:00 AM		Permit Finaled	10/06/2011 12:00:00 AM	ADDRESS	34.05134	-118.25661	TI IN AN EXISTING OFFICE. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73419	15041-20000-22176	17332 W DEARBORN ST	91325	12	198B129   388	2766012010	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			07/13/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.23693	-118.51275	PV1 SFD. TOTAL SYSTEM SIZE 11KW AC USING 46 MICROINVERTERS. USING ENPHASE M250. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73420	14041-20002-33482	6320 N TOPANGA CANYON BLVD UNIT 1640	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/31/2015 12:00:00 AM			PC Approved	07/31/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	"(20002) - Changes to approved set.  Adding new 125 A panel ""Chef's Table"" to supply counter loads.*****Previous Work Description (20001)*****07/29/2015 Changes to an approved set of plans. Changes include the installation of bug-eyes, revised photometric analysis, and the removal of a 200-amp panel. All changes have been clouded.*****Previous Work Description (20000)*****New 1-story building for a restaurant.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy. Part of westfield village project. this is TI. Il Fornario"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73421	15041-20001-39143	7409 N WESTCLIFF DR	91304	12	186B089   324	2027044008	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM			PC Approved	01/13/2016 12:00:00 AM	PIN	34.20679065	-118.65240976	**Expedite Fee***PV1, roof mounted solar panel, 3.8kW AC system, added to an (E) PV system 5kW AC(17)modules: #KU2656ZPA(1) inverter: SE3800A-US-ZB-U(1) Load center 125A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73422	14041-20000-11822	415 S WINDSOR BLVD	90020	4	135B189   465	5505027008	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			05/02/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.06653	-118.32159	PV1.  Install 6 kW roof-moutned PV system, interconnect with main service panel.  (24) modules w/ (24) microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73423	12041-10000-27702	409 S BURLINGTON AVE	90057	1	133-5A205 194	5154023014	R4-1	Central	Westlake	Westlake North		2089.04	Electrical	Electrical	Apartment			11/16/2012 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.06028	-118.26974	PLAN CHECK FOR POWER AND ENERGY. NEW 30 UNIT 4STORY AFFORDABLE APARTMENT with 1600A SERVICE. BELOW GRADE PKG. METHANE.9 TYPICAL UNIT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73424	14041-20000-15724	12184 W VENTURA BLVD	91604	2	162B165   203	2369004043	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	34.14315	-118.39805	Plan check for Tittle 24 only on a commercial building with 1519 SQ feet under customer request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73425	13041-10001-10688	20520 W NORDHOFF ST	91306	3	195B109    72	2780001050	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			07/01/2013 12:00:00 AM			PC Approved	07/01/2013 12:00:00 AM	PIN	34.23141269	-118.58091638	Supplemental description: Addition of 4 smoke detectors and one notification appliance to second story. Original work description: New fire alarm system for 2-story commercial building.  78 devices, 1 new panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73426	17041-20000-26825	1237 W YOSEMITE DR	90041	14	160-5A229 234	5690019013	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Issued	08/03/2017 12:00:00 AM	ADDRESS	34.13365	-118.19251	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (18) modules, (18) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73427	11041-20000-19029	12025 E WATERFRONT DR BLDG 3-2ND FLR	90094	11	105B165   915	4211011031	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			09/08/2011 12:00:00 AM	10/07/2011 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	PIN	33.98296022	-118.40473838	PLAN CHECK POWER AND ENERGY FOR USC ICT ON 2ND FLOOR. INSTALLATION EXCEEDS 400A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73428	17041-20001-40652	5331 E BALTIMORE ST	90042	1	154-5A227 223	5478009042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.11752	-118.20019	Expedited plan check fee.  PV1.  Install roof-mounted grid-tied 4.875 kW PV system.  (15) modules with 5 kW rated central inverter.Install 27 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73429	17041-20000-00227	5900 W WILSHIRE BLVD 18th Floor	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/04/2017 12:00:00 AM			PC Approved	01/04/2017 12:00:00 AM	ADDRESS	34.06237	-118.35809	Plan check for Title 24 only. Project site is existing restrooms within a high-rise building. Project scope is a tenant improvement. Total lighting area = 464 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73430	16041-20000-06807	716 S SPRING ST	90014	14	127-5A211 124	5144015042	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM			PC Info Complete	05/24/2016 12:00:00 AM	ADDRESS	34.04398	-118.25255	Plan check for power and lighting. Project site is an existing commercial building. Project scope is a change of use from office to restaurant. Work includes a new 600-amp service and associated loads. Total lighting area = 5,072 sq. ft.Note: Building application has been created under 13016-20002-26159	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73431	19041-20001-06477	11972 W CHALON ROAD	90049	11	141B141   123	4429039008	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	34.08314	-118.47959	PLAN CHECK ONLY, SUPPLEMENTAL FOR CHANGES TO APPROVED PV SET, REMOVAL OF A JUNCTION BOX ON SINGLE LINE DIAGRAM AND ROOF  MOUNTING PLAN, CLOUDED CHANGES ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73432	13041-10001-28406	110 S FAIRFAX AVE A14	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/21/2014 12:00:00 AM			PC Approved	03/21/2014 12:00:00 AM	ADDRESS	34.07371	-118.36119	CHANGES TO APPROVED SET. PLANCHECK ONLY. ADDITION OF ELECTRICAL ROOM AND 2 FIXUTERS ONLY. TITLE 24 ENERGY PLAN CHECK ONLY.  BLAZE RESTAURANT. NO CHANGE IN OCCUPANCY. EMERGENCY LIGHTING. 1,127SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73433	10041-10000-25737	325 W ADAMS BLVD	90007	9	123A205   197	5126018035	[Q]C2-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	06/22/2012 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.02712	-118.27319	NEW 6 LEVEL MIXED USE RESIDENTIAL (915 UNITS, 5 LEVELS) & RETAIL (1 LEVEL).  WITH A 4160 V, 1000 AMP SERVICE.  PLAN CHECK IS FOR POWER & ENERGY.   (3 LEVELS OF PARKING STRUCTURE BELOW SUBMITTED UNDER EPC #10041-10000-25736 & Bldg PC# 10010-10000-01204).  VARIANCE FOR WILL BE REQUIRED TO SEPERATE THE FIRE LIFE SAFETY SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73434	17041-20001-45197	6150 N LAUREL CANYON BLVD Bldg H	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.18223	-118.39491	Revisions to approved set.  Value engineering from copper feeders to aluminum.  Minor branch circuit revisions and relocation of some equipment throughout the plans.  Approval for clouded delta-2 and 3 revisions only.  (((Open air mall - Building H - 2-story addition, core and shell. New 34.5kV transformer and 4000A switchboard rated 277/480V 3ph 4w. T24 area: indoor-9,340sqft; outdoor-132,570sqft.  Plan check for power and energy. BUILDING PERMIT # 16014-10000-06045)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73435	19041-10000-45668	1700 S OGDEN DR	90019	10	126B177   129	5069004001	R1R3-RG	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.04501	-118.36601	]EPLAN] 1 NEW ENERGY STORAGE SYSTEM THAT IS CONNECTED TO AN EXISTING PV1.  EXISTING 200A MAIN SERVICE PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73436	15041-20000-15205	320 S HAMPTON DR BLDG B	90291	11	111B141   717	4286005010	M1-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	33.99612	-118.47637	Plan check for Title 24 only. Project scope is a tenant improvement. Total lighting area = 3,320 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73437	17041-20000-23371	3353 N CAHUENGA BLVD WEST	90068	4	159B181   484	2425026011	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	07/12/2017 12:00:00 AM		Permit Finaled	03/16/2018 12:00:00 AM	ADDRESS	34.1311	-118.35152	Plan check for energy only. TI to existing commercial building (offices, retail). New lighting - 1,712sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73438	16041-10001-13907	670 S SANTA FE AVE	90021	14	124-5A217 135	5164018003	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			PC Approved	10/31/2016 12:00:00 AM	ADDRESS	34.03584	-118.23011	10/31/16Changes to an approved set of plans. All changes are clouded under delta 1. Changes include adding/removing/relocating lighting fixtures and receptacles, and revising title 24 calculations.Note: Permit is paid under PCIS#16041-10000-13907 (((((((T-24, PC FOR ENERGY ONLY. CHANGE OF USE TO A CATERING KITCHEN. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 2055 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73439	08041-20006-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM			Corrections Issued	12/13/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to previously approved set of drawings.  PLAN CHECK ONLY FOR ""DELTA 218"" CHANGES.    <<<<NEW HIGH RISE BUILDING - MEDICAL OFFICE (SHELL ONLY)>>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73440	10041-20000-24350	10880 W WILSHIRE BLVD #830	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			12/07/2010 12:00:00 AM	12/07/2010 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.05885	-118.44283	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR OFFICE TI UNIT #830.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73441	15041-20000-12508	6256 N TOPANGA CANYON BLVD 1270-C	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	TI to new commercial building (retail). First time tenant. Plan check for power and energy. Adding new lighting including emergency. Total Sqft. 974.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73442	18041-20001-48748	8218 N WILKINSON AVE	91605	2	192B165   630	2308020004	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2018 12:00:00 AM			PC Approved	01/17/2019 12:00:00 AM	ADDRESS	34.22051	-118.40401	expeditepv1install roof mounted pv system sized 7.6KW AC interconnected with msp.(2) tesla 5KWh batteries	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73443	11041-20000-14128	12975 W JEFFERSON BLVD	90066	11	102B157    93	4211008026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.01	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2011 12:00:00 AM	11/10/2011 12:00:00 AM		Permit Finaled	12/12/2011 12:00:00 AM	ADDRESS	33.97533	-118.42387	Replace an existing Generator with a new one. EPC for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73444	15041-20000-29337	6225 W CENTURY BLVD 2nd Floor	90045	11	090B165     5	4124026005	C2-2, [T][Q]C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	33.9457	-118.39456	Plan check for power and energy. Project site is an existing commercial high-rise building (hotel). Project scope is the renovation of the 2nd floor. Place of assembly. Total lighting area = 33,000 sq. ft.Note: Building permit application filed under 15016-10000-09748	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73445	16041-10002-35625	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	PIN	33.94094587	-118.40577128	Addition of three 75 kVA transformers and three 200 amp panels for temp power (LAX).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73446	17041-20000-15012	6200 N VARIEL AVE	91367	3	177B105   132	2149004024	CL(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/05/2017 12:00:00 AM		Permit Closed	06/29/2017 12:00:00 AM	ADDRESS	34.18341	-118.59258	temporary power for construction 600 amps.plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73447	19041-20001-52886	4545 N ENCINO AVE	91316	5	165B129    68	2290019003	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	01/03/2020 12:00:00 AM	ADDRESS	34.15223	-118.5142	PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTE. SYSTEM SIZE IS 21.9 KW DC/20.44 KW AC. SCOPE OF WORK CONSISTS OF (60) PV MODULES WITH (2) 10KW INVERTERS AND A 125A LOAD CENTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73448	14041-10001-07985	7301 W WORLD WAY WEST TBIT L4 &-L5	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM			PC Approved	03/28/2014 12:00:00 AM	PIN	33.94386821	-118.41794839	plan check only. changes to approved set of plans: changed some lights to emergency being fed by generator.old description: TENANT IMPROVEMENT AT THE TBITEC OFFICES/CONFERENCE ROOMS; TERMINAL CONFERENCE OFFICES AND ANA AND PACIFIC AVIATION LEVEL 5 NORTHPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73449	07041-20001-23114	14424 W DICKENS ST	91423	5	166-5A151 237	2266006019	RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1412.00	Electrical	Electrical	Apartment			09/23/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	04/05/2012 12:00:00 AM	ADDRESS	34.14945	-118.44699	Changes from previously approved plans.  Relocate main switchboard and add chairlift equipment. All changes indicate by DELTA 1 as shown on plans.  Plan check for power only.  Per LADWP no change in available fault currentNote: Approved plans submitted for reference only.*****NEW 9-UNIT APT BLDG. Variance to separate fire alarm submitted 9/21/07.New P/check expiration and last date to obtain a permit: 01-21-2010*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73450	19041-20000-47055	7025 S MAIN ST	90003	9	102B201   656	6012010034	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.10	Electrical	Electrical	Apartment			11/15/2019 12:00:00 AM	11/15/2019 12:00:00 AM		Permit Finaled	04/21/2022 12:00:00 AM	ADDRESS	33.97582	-118.27416	Plan check for new Fire alarm system, fire alarm system devices: 50 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73451	17041-10000-32072	1128 N CITRUS AVE	90038	4	144B185   604	5532019019	M1-1VL-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Issued	09/15/2017 12:00:00 AM	ADDRESS	34.09165	-118.33967	PC FOR WAREHOUSE TI  FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS, EQUIPMENT AND RECEPTACLES. TOTAL AFFECTED AREA 7205 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73452	14041-10000-35209	436 N LA CIENEGA BLVD	90048	5	141B173  1304	5514001005	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM			PC Approved	12/19/2014 12:00:00 AM	ADDRESS	34.07915	-118.37637	TI for barber shop.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73453	14041-10000-00520	8301 N RESEDA BLVD	91324	12	192B125   654	2785018068	C2-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM			PC Approved	01/08/2014 12:00:00 AM	ADDRESS	34.22097	-118.53628	Plan check for T24 only. Total area 748 sq ft. El Polo Loco store.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73454	17041-20000-05501	12121 W BLUFF CREEK DR 1st flr	90094	11	102B165   990	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	33.97874	-118.40463	ti to an existing commercial building adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 4012.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73455	18041-10000-15412	2938-2952 N ALLESANDRO ST	90039	13	150B213   787	5442024026	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM			Verifications in Progress	09/24/2018 12:00:00 AM	ADDRESS	34.10496	-118.24522	FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW  3-STORY MIXED USE BUILDING WITH RETAIL SPACE AND 32 LIVE/WORK UNITS WITH GROUND LEVEL GARAGE.Note that this application was withdrawn; a PLAN CHECK ONLY application 18041-10000-39227 is approved	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73456	17041-20001-43921	6634 W 87TH PL	90045	11	096B165   864	4122019006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	33.95777	-118.40571	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array and AC coupled battery backup system for SFD.3kW ungrounded pv system. (9) 300W pv modules. (1) Tesla Powerwall 2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73457	10041-10000-06613	440 S VERMONT AVE	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Public Safety Only			04/12/2010 12:00:00 AM	04/12/2010 12:00:00 AM		Permit Finaled	12/10/2010 12:00:00 AM	ADDRESS	34.0659	-118.29143	NEW FA SYSTEM FOR A 3-STORIES/BASEMENT  COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73458	14041-20001-15473	7741 N BLUEBELL AVE	91605	2	189B161  1003	2305032016	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.2112	-118.41172	Fee for expedite only.*****New roof mounted PV sytem with optimizers and transformerless inverter.  Total system size 10.25KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73459	14041-10000-32385	12017 W VOSE ST	91605	2	183B165   111	2321003034	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM	11/20/2014 12:00:00 AM		Refund in Progress	10/06/2015 12:00:00 AM	ADDRESS	34.19855	-118.39489	T24. REMOVE HID LIGHT FIXTURES AND REPLACE WITH  NEW LED FIXTURES. TOTAL AREA 1464SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73460	14041-20000-34278	19636 W OXNARD ST	91356	3	177B117   673	2153024027	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/27/2015 12:00:00 AM	ADDRESS	34.17914	-118.56143	low permit fee due to senate bill 1222 from 2012 fee cap.PV1. INSTALL ROOF-MOUNTED SOLAR ARRAY. INTERCONNECTED WITH MAINSERVICE PANEL. SYSTEM SIZE 10 KW. (43) KYOCERA KD255GX-LFB3 MODULES(2) SOLAREDGE  INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73461	12041-20000-15848	812 W 165TH PL Bldg A	90247	15	066B197    18	6121007036	R3-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	08/29/2013 12:00:00 AM	ADDRESS	33.88061	-118.28977	New electrical system for building A.  Power and energy.  Service at building A supplies building B.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73462	18041-10000-28964	10935 W VENICE BLVD	90034	5	117B161   909	4252019017	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.02	Electrical	Electrical	Commercial			08/01/2018 12:00:00 AM			PC Approved	08/16/2018 12:00:00 AM	ADDRESS	34.01559	-118.41299	This is Plan checkonly for T24, Change of use from Retail to Message parlor. Permit has been issued under 18041-30000-20130	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73463	18041-10000-34045	17552 W TUSCAN DR	91344	12	222B129   241	2601044010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.30265	-118.51567	PLAN CHECK FOR ROOF MOUNTED (10.841AC) PV SYSTEM ONLY WITH SUNPOWER MONITORING SYSTEM- SYSTEM CONSIST OF 36 AC MODULES(SPR-X21-35-D-AC). EV CHARGER AND SERVICE PANEL UPGRADE NOT PART OF SCOPE. SEPARATE PERMIT REQUIRED.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73464	13041-10000-34215	1101 E CESAR E CHAVEZ AVE	90033	14	130-5A219  55	5410010025	M1-2D	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.05348	-118.22335	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For autoshop (NON-HAZARDOUS PER APPLICANT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73465	17041-30001-12250	524 E WASHINGTON BLVD	90292	9	121-5A209  49	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM			PC Approved	05/15/2018 12:00:00 AM	PIN	34.02811119	-118.25991573	Revision to approved set due to architectural change: relocating the air curtain due to relocation of the door. Air curtain still using the same circuit (B-39). This is plan check only, permit is covered under master # 17041-20000-12250<<Interior restaurant TI (Panda Express) to include new panels, lighting, and outlets.  Plan check for power and energy per applicant's request.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73466	18041-20000-16467	14853 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.29454	-118.45507	Plan check for PV roof mounted system, system size: 3.8kW with 12 modules and 1 inverter(3.8kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73467	13041-20000-13125	7380 W MELROSE AVE	90036	5	141B181   608	5526020027	C4-1XL	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	PIN	34.08331805	-118.35079387	CHANGE OF USE FROM RETAIL  TO NAIL SALON.   LOAD IS LESS THAN 225 AMPS PER APPLICANT.  PLAN CHECK ONLY FOR ENERGY, WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73468	18041-20004-17751	11805 W GWYNNE LANE	90077	5	153B141   103	4378037075	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM			PC Approved	02/14/2019 12:00:00 AM	ADDRESS	34.11583	-118.47417	2/14/2019changes to an approved set of plans.  changes to removing one module decreased to 9.24 kw dc. ((((PV1.  Install 9.425 kW DC roof mounted grid tied PV system.  (29) modules with (2) 5.2 kW rated string inverters.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73469	12041-20000-09045	5539 N RIVERTON AVE	91601	2	174B173  1109	2416014026	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	03/17/2015 12:00:00 AM		Issued	03/17/2015 12:00:00 AM	ADDRESS	34.17108	-118.36581	Brand new pre fab metal storage warehouse. 9200 unconditioned sqft, 400 conditioned sqft. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73470	14041-10000-16821	904 W 28TH ST	90007	9	121-5A201  60	5123004403	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	08/18/2014 12:00:00 AM	ADDRESS	34.02829	-118.28259	NEW FIRE ALARM SYSTEM. 2-STORY BUILCING, GROUP R-2 USC AEP BUILDING RENOVATION. I NEW PANEL.36 NEW DEVICES. USING SOME OF EXISTING DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73471	19041-10000-46681	130 S SOTO ST 1-5	90033	14	127-5A223 273	5180003030	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Apartment			11/13/2019 12:00:00 AM	12/27/2019 12:00:00 AM		Permit Finaled	02/14/2020 12:00:00 AM	ADDRESS	34.04277	-118.21018	PC for PV system for (commercial building), 30 PV modules HANWA, with microinverters and 2 load centers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73472	16041-20000-08074	13200 N GLADSTONE AVE	91342	7	225B157   709	2510020008	RA-1-K	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	06/01/2016 12:00:00 AM	ADDRESS	34.31078	-118.42793	Plan check for a PV1 roof-mounted PV system. System size is 11.6 kWac and consists of (3) inverters, (1) load center, (50) modules, and (1) combiner box.Note: $0.00 permit fees dues to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73473	15041-20000-27689	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM			Reviewed by Supervisor	09/04/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for a PV2 roof-mounted PV system. Total system size is 840 kWac and consists of (30) 28 kWac inverters and (3,204) modules. PV system is composed of two sub-systems: System C and System D.System C:  308 kWac(11) inverters and (1,188) modulesSystem D: 532 kWac(19) inverters and (2,016) modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73474	19041-10000-35084	1515 W 190TH ST STE. 275	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	01/08/2020 12:00:00 AM	ADDRESS	33.85852	-118.30531	TENANT IMPROVEMENT WORK ON APPROX. 12,373 SF OF TOTAL FLOOR AREA IN SUITE# 275. INSTALLING LIGHTS. T-24 ENERGY ONLY. PERMIT FOR NEW CIRCUITS.BULDING PERMIT: 19016-40000-25449	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73475	10041-10000-02350	2049 S CENTURY PARK EAST 2460	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/10/2010 12:00:00 AM			PC Info Complete	02/10/2010 12:00:00 AM	ADDRESS	34.05903	-118.41293	TI - Suite 2460 - Minor revisions to office area outlets and lighting.  (7 receptacles, 4 light fixtures).  P/C is for Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73476	12041-10001-08438	12930 W VENTURA BLVD	91604	2	165B161  1027	2385026024	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Info Complete	08/03/2012 12:00:00 AM	ADDRESS	34.14513	-118.41481	DELTA 2 CHANGES TO THE APPROVED PLANS. CHANGING THE SIZE OF TRANSFORMER FROM 112.5 KVA TO 75 KVA IN THE SAME LOCATION. THE TOTAL LOAD ON THE TRANSFORMER IS 52.8 KVA.  PLAN CHECK ONLY.  PERMIT WAS ISSUED ON 12041-10000-08438. <<<T.I. to restaurant, change from Baja Fresh to Five Guys Burgers.  Less than 400A of load and the occupancy load is 71, per applicant.  Full Plan check for Power and Energy, requested by the applicant.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73477	14041-10000-04958	2921 E CALLE PEDRO INFANTE	90063	14	124-5A225 260	5185019016	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.03455	-118.20535	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE3800A-US-ZB-U(14) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73478	17041-10000-13444	2134 W SUNSET BLVD Suite G	90026	13	139-5A207 141	5402035024	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.07723	-118.26485	PC for energy only, Indoor Title 24. Converting from restaurant to new coffee shop with covered outdoor dining. New lighting and power. New added load is less than 400 Amps. Area:2,715 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73479	11041-20000-22721	14006 W RIVERSIDE DR Dining-Terrance	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	01/24/2012 12:00:00 AM		Permit Finaled	06/28/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check power and energy for TI Dining Terrance remodel. New panels, ckts, transformers and including replacing existing T6 transformer supplying R6 panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73480	15041-20001-43906	7929 S FORDHAM ROAD	90045	11	099B157    80	4113021004	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2765.00	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	33.96654	-118.41889	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (21) modules. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73481	18041-20005-01171	1942 N SAN YSIDRO DR	90210	5	150B157   163	4384030012	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	10/23/2018 12:00:00 AM	ADDRESS	34.10647	-118.42415	10-03-2018 Changes to an approved set of plan, changes include PV Module update to 320W, Update PV System size: 14.4kWFees $ 0.00 due to California Sanate Bill 1222 Assebly Bill 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73482	14041-10000-05565	624 S GRAND AVE SUITE 2500	90014	14	129A209   107	5144004014	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/28/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	PIN	34.04778206	-118.25563275	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE ON SUITE 2500 ON  25TH FLOOR. NO CHANGE IN OCCUPANCY. <400 AMPS NEW CONNECTED LOAD. ALL WORK TO BE INDOORS. 4664 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73483	14041-20001-02421	6904 N VANTAGE AVE #115	91605	2	183B165   722	2321010076	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2014 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.19578	-118.39751	(((EXPEDITE FEES))PV1 SOLAR FOR SINGLE UNIT. TOTAL SYSTEM SIZE 4.2 KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73484	15041-20001-29269	10201 W PICO BLVD pico w. pa-rking stru	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/03/2015 12:00:00 AM			PC Approved	09/30/2015 12:00:00 AM	PIN	34.05182951	-118.41257696	Expdite per applicant (((PV2 Installation of (1) commercial carport canopy solar PV Power system,(764) modules: sunpower SPR-E20-327-COM(7) inverters: CPS SCA 28KTL-DO/US2 out of 3 sites on the same address.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73485	17041-20000-01487	19450 W HALSTED ST	91324	12	201B117   645	2761003014	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	04/20/2017 12:00:00 AM	ADDRESS	34.24376	-118.55765	pv1install roof mounted pv system sized 9.9kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73486	11041-10000-10868	1600 W 240TH ST	90710	15	042B193   767	7439014013	[Q]MR1-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01, 2933.02	Electrical	Electrical	Commercial			05/26/2011 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	06/16/2011 12:00:00 AM	ADDRESS	33.80713	-118.3054	NEW FIRE ALARM SYSTEM IN COMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73487	15041-20000-19743	23067 W VENTURA BLVD Suite 204	91367	3	171B097   680	2042012057	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	PIN	34.16407118	-118.62895762	"PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO  OFFICE.  SUITE 204.  868 SQFT.""COMPLY WITH DEPARTMENT ORDER effective date 04/16/2015. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73488	14041-10000-26775	11906 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	10/01/2014 12:00:00 AM	ADDRESS	34.05239	-118.47055	Energy plan check for a retail store with total area covers 1206 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73489	10041-10000-24564	8401 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			12/09/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	03/11/2011 12:00:00 AM	ADDRESS	34.22253	-118.62558	Adding hardscape lighting to previouly unlighted parking lot.  The source of supply is in an existing building as shown on the plan.  An existing automatic time clock is located adjacent the existing panel.  Verify that the existing time clock is T-24 certified as an astronomical time clock shut-off control.  section 132	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73490	13041-20000-32773	8214 N VAN NUYS BLVD	91402	6	192B149   493	2212004033	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.22025	-118.44858	PC FOR T24 ENERGY ONLY. NEW LIGHTING. RETAIL/ SHOWROOM. TOTAL AREA 4169 SQ FT. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73491	17041-20000-23702	1354 W 190TH ST	90501	15	060B193   453	7351002032	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM			PC Info Complete	01/11/2018 12:00:00 AM	ADDRESS	33.85803	-118.30147	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.  total square footage 2715.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73492	16041-10000-40338	3372 N STONERIDGE LANE	90077	4	159B149   305	2278032032	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.13197	-118.45864	Service upgrade from 400 amps to 600 amps to accomidate new detached gym and garage extension in existing SFD.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73493	16041-20000-37591	16633 W VENTURA BLVD SUITE 802	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.15823	-118.49571	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR MEDICAL OFFICE. SUITE 802. HIGH RISE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73494	13041-10001-06753	1090 W 7TH ST	90017	1	130-5A207 630	5143004011	CW	Central	Westlake	Downtown Los Angeles		2093.00	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/02/2013 12:00:00 AM	ADDRESS	34.05065	-118.26411	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 13041-10000-06753. BUILDING IS A HIGH RISE WITH EXISTING GENERATOR.***************************************************************T24 FOR NON-HIGHRISE OFFICE SPACE. SQRFT 3990. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY. INSPECTOR VERIFY THIS BUILDING IS NOT A HIGHRISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73495	16041-10000-43970	1901 S AVENUE OF THE STARS 17th Floor	90067	5	132B161    35	4319003055	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/14/2016 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.41705	Plan check for Title 24 only in existing high-rise Building T.I. office space. Total area: 8,187 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73496	11041-10000-22585	13171 W MINDANAO WAY	90292	11	105B153    95	4212004005	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	12/27/2011 12:00:00 AM	ADDRESS	33.98487	-118.43775	Addition of 9 new wall washer lights.  PLAN CHECK ONLY for Energy, with NO CHANGE to existing emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73497	14041-10000-34539	10269 W SANTA MONICA BLVD 1-19	90024	5	132B157   294	4327018011	(T)(Q)RAS4-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			12/12/2014 12:00:00 AM	04/08/2015 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.05994	-118.42117	Power plan check for new 4 story 19 unit apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73498	18041-30000-26592	2734 N FLETCHER DR	90039	13	151-5A211  83	5436031016	[Q]C2-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	Apartment			07/17/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	11/18/2018 12:00:00 AM	ADDRESS	34.11088	-118.25053	Install rooftop solar system in a commercial building,  7.2 kW AC/ 6.516 kW CEC AC, (20) modules, (10) microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73499	18041-10000-07075	1850 N CHEROKEE AVE	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.10481	-118.33464	void application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73500	18041-20000-07095	900 W WILSHIRE BLVD STE 113	90017	14	130-5A209 239	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	06/08/2018 12:00:00 AM	ADDRESS	34.05001	-118.25963	PLAN CHECK FOR TITLE 24 ONLY FOR - NON-STRUCTURAL TENANT IMPROVEMENT FOR COMMERCIAL OFFICE - TOTAL AFFECTED AREA = 688 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73501	17041-10000-04304	11955 W SUNSET BLVD	90049	11	135B141   761	4402010028	R1-1, RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.06247	-118.47358	PC for outdoor title 24 only. Removing HID fixtures and replacing them with new LED ones. Area: 10,400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73502	18041-20000-35424	1431 N AVENIDA DE CORTEZ	90272	11	138B117   231	4431007026	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	PIN	34.07336225	-118.56363151	PV1.  Install 8.25 kW DC/7.4 kW AC roof mounted grid tied PV system. (25) modules with 10 kW rated string inverter.  Derating of main breaker.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73503	19041-30000-52043	11055 W FRUITLAND DR 1-9	91604	2	162B173   527	2378008012	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1438.00	Electrical	Electrical	Apartment			12/17/2019 12:00:00 AM	08/10/2020 12:00:00 AM		Permit Finaled	04/15/2022 12:00:00 AM	ADDRESS	34.14011	-118.37186	FULL PC FOR A NEW APARTMENT, SCOPE OF WORK INCLUDES A NEW 800A SERVICE (120/240 3P,4W) THAT FEEDS TWO 400A SWITCHBOARDS (MSA AND MSB). MSB FEEDS  TWO HOUSE PANELS, NOTE THERE IS A 30KW EMERGENCY GENERATOR THAT IS INTERCONNECTED TO A 100A DISTRIBUTION  PANEL THAT FEEDS A 13.3HP ELEVATOR AND A EMERGENCY SUBPANEL. MSA FEEDS NINE SUBPANELS (DWELLING UNITS) TOTAL AFFCTEED AREA IS 13,484 SQFT. PER BUILDING ((NEW 4 -STORY,  9-UNIT  APARTMENT WITH ONE LEVEL OF SUBTERRANEAN PARKING GARAGE16010-10000-04520))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73504	16041-10000-15690	18133 W VENTURA BLVD 2 & 4 FLR-#201 & 402	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			05/04/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.16603	-118.52861	TI TO SECOND AND 4TH FLOOR, PLAN CHECK FOR POWER AND ENERGY. MEDICAL OFFICE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73505	15041-10000-41699	4250 S LINCOLN BLVD	90292	11	105B153    73	4230001018	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			12/10/2015 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	03/24/2016 12:00:00 AM	ADDRESS	33.98612	-118.44354	TI, RESTAURANT. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73506	11041-10001-21544	10000 W PICO BLVD BLDG 4	90064	5	129B165     1	4307019001	A1-1XL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			02/14/2012 12:00:00 AM			PC Approved	02/17/2012 12:00:00 AM	ADDRESS	34.05211	-118.40654	"Delta 4 revision to approved plans for new ""Gateway Building"" - Building 4 at Hillcrest Country Club.  PLAN CHECK ONLY for Energy with Emergency lighting."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73507	12041-20000-24336	968 S FEDORA ST	90006	10	129B197    51	5078004019	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.10	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2012 12:00:00 AM	10/23/2012 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.05363	-118.29776	Plan check for PV. Single family dwelling. Enphase micro inverters. 3.36kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73508	15041-10000-35424	3994 S FIGUEROA ST	90037	9	115-5A201  59	5037032040	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2311.00	Electrical	Electrical	Commercial			10/22/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.01147	-118.28254	PC FOR POWER AND ENERGY. CHANGE OF USE FROM DENTAL TO 711 STORE. TOTAL AREA 2763 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73509	17041-10000-14398	13960 W VENTURA BLVD	91423	4	165B153   540	2266016033	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.14877	-118.43691	PC for energy only, Indoor Title-24. Removing HID fixtures and replacing them with new led ones. Area: 2650 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73510	17041-10001-44392	13029 W VICTORY BLVD	91606	2	180B161   790	2326017013	(T)(Q)C2-2D	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Apartment			03/09/2018 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.18799	-118.4167	PC FOR POWER FOR FIRST TIME TENANT. T-24 DONE UNDER MASTERSCOPE INCLUDES NEW CIRCUITS AND EQUIPMENT. PERMIT PAID UNDER MASTER APPLICATION. THIS IS PLAN CHECK ONLY!!******************************************** PC FOR RETAIL STORE (SPRINT) FOR T-24 ENERGY ONLY.TOTAL EFFECTED AREA IS 1770 SQ.FTSCOPE OF WORK INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. B# 17016-10000-36118	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73511	15041-10000-20616	3231 S LA CIENEGA BLVD	90016	10	123B173  1684	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.02942	-118.37312	INSTALL NEW FIRE ALARM SYSTEM WITH 30 FA DEVICES AND ONE CONTROL PANEL, ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73512	19041-20000-04643	1130 S RIDGELEY DR	90019	4	132B177  1180	5085008012	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.05487	-118.35328	Plan check for a PV1 roof-mounted PV system. System size is 15.12 kWdc/13.44 kWac and consists of (42) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73513	15041-10001-29028	700 S FLOWER ST G240	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/30/2016 12:00:00 AM	12/27/2016 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	RECHECKING NEW SET OF PLANS. PROVIDING NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73514	17041-10000-24578	2230 E CENTURY BLVD 101-205	90002	15	091-5A217 111	6046019929	RAS3(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Apartment			08/07/2017 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/11/2020 12:00:00 AM	ADDRESS	33.94631	-118.23242	NEW 3 STORY, 8 UNIT APARTMENT BUILDING, 400A 208/120 V SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73515	18041-20000-14739	9958 N INDEPENDENCE AVE	91311	12	204B109   491	2747002022	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2018 12:00:00 AM	04/23/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.25164	-118.59061	PC for rooftop solar for 11.4kW(ac)/14.06kW(dc). Intalling 38 modules, with optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73516	16041-30000-01904	11309 S ATHENS WAY	90061	8	087A203   238	6074024039	C2-1VL	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	Apartment			01/19/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	07/06/2016 12:00:00 AM	ADDRESS	33.93166	-118.27905	Installation of fire alarm system in new 9 unit 3 story apartment building.  Total system size = 41 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73517	13041-20002-03947	1925 S BUNDY DR	90025	11	123B149   353	4259018008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM			PC Approved	09/15/2014 12:00:00 AM	ADDRESS	34.0346	-118.45665	changes to approved set of plans. changes to site lighting. t24 only. pc only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73518	15041-20000-40289	5905 N MCDONIE AVE	91367	3	177B113   242	2151005022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	04/01/2016 12:00:00 AM	ADDRESS	34.17793	-118.57275	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.0KWac. (43) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-ABB #PVI-6000-OUTD-US-Z-A AND ABB #PVI-3.0-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73519	14041-10000-17333	1969 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.06159	-118.20463	Title 24 plan check only.  Total area = 2,375 sq. ft.Lighting retrofit.  Scope of work includes 3 total rooms, but only 1 has more than 50% change in lighting and is therefore included in title 24 calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73520	18041-30000-35996	412-414 E WASHINGTON BLVD	90292	9	123A207   246	5127019015	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	PIN	34.02911805	-118.26146367	PC FOR RESTAURANT TI  FOR DUNKIN DOUNTS COFFEE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, EQUIPMENT,  CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 1835 SQ.FT.B#18016-10000-23162	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73521	10041-20000-23744	203 S LOS ANGELES ST	90012	9	130-5A213 204	5161026901	C2-4D	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Public Safety Only			11/29/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	01/24/2011 12:00:00 AM	ADDRESS	34.05021	-118.24366	PLAN CHECK FOR NEW INSTALLATION OF FIRE ALARM SYSTEM FOR LA LITTLE TOKYO BRANCH LIBRARY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73522	16041-10000-26161	8140 N TILDEN AVE	91402	6	192B149   578	2212005017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.21916	-118.44722	PV SYSTEM TOTAL SIZE 3.6KW AC USING MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73523	17041-20000-14243	1414 N CATALINA ST	90027	13	147B197   848	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/22/2018 12:00:00 AM		Issued	05/22/2018 12:00:00 AM	ADDRESS	34.09716	-118.29486	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes a new 4,000-amp service, new distribution equipment, and a total lighting area of 25,146 sq. ft. Scope of work in building includes a spray room, repair shop, and dentist office.Note: Building application has been generated under 17016-10000-08658	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73524	16041-10000-41775	1820 W SLAUSON AVE	90047	8	108B193  1398	6001001024	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Finaled	03/14/2017 12:00:00 AM	ADDRESS	33.98794	-118.31101	PC FOR ENERGY ONLY, REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. TOTAL AREA 199650 SQ FT. (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73525	12041-20000-18845	14117 W HUBBARD ST #2A	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			08/10/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	02/25/2013 12:00:00 AM	ADDRESS	34.29849	-118.44081	Install electrical for spaec 2A.  Plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73526	14041-20000-16155	9401 N OSO AVE	91311	12	198B113    99	2748022086	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			06/17/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	07/29/2014 12:00:00 AM	ADDRESS	34.2411	-118.57555	Plan check for energy only. New lighting (incl. emergency) in commercial warehouse. 23,097 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73527	18041-10001-24591	333 S HOPE ST 1400	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			08/27/2018 12:00:00 AM			Corrections Issued	08/28/2018 12:00:00 AM	ADDRESS	34.05326	-118.25292	THIS IS PLAN CHECK ONLY. PERMIT FEES PAID UNDER MASTER. PC FOR CHANGES TO APPROVED SET FOR ADDITIONAL PRIVATE OFFICE SPACE  (#1509) ON THE WEST SIDE OF THE FLOOR. SCOPE INCLUDES ENCLOSING THE OFFICE SPACE AND PROVIDING POWER WITH T24 REVISIONS. PC FOR OFFICE TI  IN A HIGH RISE FOR TITLE 24 ENERGY ONLY.TOTAL AFFECTED AREA 20,330.5 SQ.FT SCOPE INCLUDES NEW LIGHTS AND CIRCUITS. B# 18016-10000-21037	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73528	14041-10000-09661	322 S AVENUE 17	90031	1	136-5A219 118	5447029010	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.06865	-118.22186	T24 only. Remove HID light fixtures and replace with new fluorescent fixtures. Total area 6000 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73529	16041-20000-36396	17038 W OAK PARK CT	91316	5	168B133   574	2289004024	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2016 12:00:00 AM	10/13/2016 12:00:00 AM		Refund in Progress	11/08/2016 12:00:00 AM	ADDRESS	34.15932	-118.5047	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73530	18041-10000-06886	905 E 2ND ST	90012	14	129A215   387	5163003063	(T)(Q)C2-2D-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.04729	-118.23499	Plan check for power only: add (2) new distribution boards 1200A 277/480V RMS, and 800A 277/480V RMS1; and provide (6) conduits only to 'future retails'. SOW is noted under Delta-4.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73531	18041-10002-25090	7261 W ESTEPA DR	91042	7	198B197    85	2562020015	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.2426	-118.29107	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.19KWdc / 13.545KWac.(43) MODULES-PANASONIC GROUP VBHN330SA16(43) MICROINVERTERS-ENPHASE IQ7X-96-X-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73532	19041-20000-04633	2605 S SEPULVEDA BLVD	90064	5	123B153   567	4256013024	R3-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	Apartment			02/07/2019 12:00:00 AM	08/23/2021 12:00:00 AM		Permit Finaled	01/20/2024 12:00:00 AM	ADDRESS	34.0327	-118.43254	New 4-story 3-unit apartment building.  600A 240/120V 3ph-4w service. Plan check for power and energy.Note: The size of service was reduced to 120/240V, 3Ph, 400Amp (10/20/23)Building permit under 16010-30000-05451.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73533	13041-10000-15327	1519 W GRIFFITH PARK BLVD	90026	13	144A203    23	5429022004	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.09049	-118.27711	Change of use from retail (940 sq. ft.) to restaurant and combine with existing restaurant space (699 sq. ft.) to create one restaurant (1,639 sq. ft.).  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73534	11041-20000-25425	17922 W COLLINS ST	91316	12	174B129   575	2159019017	R1-1	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2011 12:00:00 AM	03/01/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	ADDRESS	34.17373	-118.52277	Photovoltaic system on roof for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73535	17041-10000-12420	10731 W RICHLAND AVE	90064	5	123B157   108	4255019006	R1-1	West Los Angeles	West Los Angeles	Westside		2711.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2017 12:00:00 AM	04/17/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.03654	-118.42237	PV INSTALLATION OF A NEW 5.320 KW DC ROOF-MOUNTED SOLAR SYSTEM ON A SINGLE FAMILY 2 STORY HOUSE.(19) MICRO INVERTERS: ENPHASE ENERGT: M250-60-2LL-S2X	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73536	14041-10000-31505	6700 W SANTA MONICA BLVD	90038	4	144B185   780	5532026023	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM	11/13/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.09055	-118.33652	Installation of new fire alarm system in existing commercial space.  101 devices + 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73537	12041-10000-00166	1629 N KILBOURN ST	90065	1	148-5A217 205	5464029015	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2012 12:00:00 AM	02/13/2012 12:00:00 AM		Permit Finaled	02/21/2012 12:00:00 AM	ADDRESS	34.10144	-118.22848	Plan check roof mounted Enphase M215 Microinverter photovoltaic system. single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73538	19041-10000-36170	9932 N CAYUGA AVE	91331	7	201B161   189	2624008032	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.25037	-118.41266	PC for PV-1, system size 9.200KW,  (23) modules with micro inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73539	17041-10000-12654	6840 W FOOTHILL BLVD	91042	7	201A201    58	2564008903	C2-1VL, R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			04/18/2017 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.24755	-118.28092	PC for energy only, Inddor/Outdoor title-24. Removing HID fixtures and installing new LED ones. Area: 50,750 SQFT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73540	18041-20000-34202	16042 W KITTRIDGE ST	91406	6	180B141   447	2233022020	R1-1-RIO, [Q]R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM	09/06/2018 12:00:00 AM		Issued	09/06/2018 12:00:00 AM	ADDRESS	34.19011	-118.48301	Plan check for PV roof mounted system, system size: 14.4kW with 44  pv modules and 2 inverters(11.4kW ans 3.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73541	18041-20001-42893	15115 W DOMINO ST	91411	6	177B145   214	2242014005	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM			PC Approved	11/19/2018 12:00:00 AM	ADDRESS	34.18408	-118.46229	Expedite per applicant requestPlan check for PV roof mounted system, system size: 18.15KW  DC, 15.43kW AC with 55 PV Modules and 2 inverters(10kW and 7.6kW)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73542	10041-20000-17007	604 E C ST	90744	15	027B209    80	7424002002	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/27/2010 12:00:00 AM			Corrections Issued	08/27/2010 12:00:00 AM	ADDRESS	33.77297	-118.25507	1.5 kw pv system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73543	13041-10000-05735	520 S VIRGIL AVE	90020	13	135A201    94	5077005022	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			03/05/2013 12:00:00 AM			PC Approved	03/05/2013 12:00:00 AM	ADDRESS	34.06457	-118.28687	13041-10000-05735T24 FOR EXISTING OFFICE SPACE. 5 STORY LOW RISE OFFICE BUILDING. PLAN CHECK FOR THE FOURTH FLOOR. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73544	13041-10000-29271	1000 W WILSHIRE BLVD # 500	90017	14	130-5A207 234	5144008022	C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.05085	-118.26078	remodel existing office spaceplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73545	13041-20000-34190	16371 W TUDOR DR	91436	5	162B137   444	2286009019	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	12/09/2013 12:00:00 AM		Permit Finaled	03/24/2014 12:00:00 AM	ADDRESS	34.13877	-118.48925	New rooftop PV system for an existing single family dwelling.  System is UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73546	18041-10000-09033	18440 W HART ST	91335	3	183B125   592	2125011008	M1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.19737	-118.53485	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73547	18041-10000-15491	7107 N CANOGA AVE	91303	3	183B105   400	2111028039	[Q]C2-1VL-CDO-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Issued	04/27/2018 12:00:00 AM	ADDRESS	34.19944	-118.59786	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73548	14041-20000-33992	7052 N VAN NUYS BLVD	91405	6	183B149   213	2217007017	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			12/08/2014 12:00:00 AM			PC Info Complete	01/29/2015 12:00:00 AM	ADDRESS	34.19892	-118.44856	Change of use from retail to banquet hall.  Place of assembly with 162 max. occupants (no dance floor).  Install branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73549	18041-20000-23568	20447 W NORDHOFF ST	91311	12	195B109    60	2781001037	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	06/26/2018 12:00:00 AM		Issued	06/26/2018 12:00:00 AM	ADDRESS	34.232	-118.57917	Tenant improvement to (E) warehouse/light industrial commercial space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73550	16041-20000-32814	8985 W VENICE BLVD #A5	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.02733	-118.39241	Plan check for power and energy. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 667 sq. ft.Note: Building application has been generated under 16016-20000-21882	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73551	19041-20000-52173	1150 N DOHENY DR	90069	4	144B169   407	5560031016	RE11-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	12/31/2019 12:00:00 AM	ADDRESS	34.09188	-118.39029	PV1.  Install 24 kW DC, 15.2KW AC roof mounted grid tied PV system and 19.8 kWh energy storage system with associated distribution.  (80) modules with (4) 3.8 kW rated inverters, (2)Energy Storage Device LG 9.8KWh. Fess $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73552	13041-10000-15789	26512 S PRESIDENT AVE	90710	15	030B193    97	7411013033	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.05	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	33.78108	-118.30364	PV1 - Plan check new roof mounted Photovoltaic System using Enphase M215 mircoinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73553	16041-20002-26775	327 S HOOVER ST 1-48	90020	13	136-5A201 207	5501022007	R4-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Apartment			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.06799	-118.2845	changes to an approved set of plans.  changes include downsize (1) inverter to 8kw and reconnect to msp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73554	13041-20000-29169	172 N LA BREA AVE	90036	5	138B181   486	5513003003	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			10/18/2013 12:00:00 AM			Corrections Issued	12/16/2013 12:00:00 AM	ADDRESS	34.07563	-118.34384	Change to lighting only in an existing retail space.  Load is less than 400 amps per the applicant.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73555	14041-20000-23731	10051 W HILLGROVE DR	90210	5	144B157   228	4357017041	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	34.09166	-118.43095	PV1.  Install 7.8 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73556	16041-10000-13640	850 N WILCOX AVE	90038	13	144B185  1247	5533027025	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			04/19/2016 12:00:00 AM	12/20/2016 12:00:00 AM		Permit Finaled	04/24/2018 12:00:00 AM	ADDRESS	34.08678	-118.33082	PC FOR ENERGY AND POWER. CONSTRUCT A (4) STORY ( 23) UNIT APARTMENT BUILDING OVER A SUBTERRANEAN GARAGE.  6 TYPICAL UNITS. P/S  IS RATED AT 1200 A. TOTAL  14386 SQ FT. B # 15010-10000-02244	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73557	19041-20000-47460	11635 W MISSOURI AVE	90025	11	126B149   927	4262020***	RD1.5-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Issued	12/05/2019 12:00:00 AM	ADDRESS	34.03946	-118.45031	PV1 NEW PV AND ESS, PV SYSTEM SIZE IS 4.74 KW DC/4.32 KW AC CEC. ESS SIZ IS 13.2 KWH. SCOPE OF WORK IS (13) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, A SUB PANEL, AND A 5 KW BATTERY.NOTE: INSPECTOR TO VERIFY CONDUCTOR LENGTH FROM MAIN PANEL TO GATEWAY TO VERIFY FAULT CURRENT CALCULATIONS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73558	15041-10000-15834	1433 W 58TH ST	90062	8	108B193  1198	5003032023	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2326.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM	06/09/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	33.98981	-118.3014	pv1, install roof-mounted solar array on single family home, interconnect with main service panel.(10)modules: lsunpower SPR327NE-WHT-D(1) INVETER: ABBPV1-3.0-TL-OUTD-US-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73559	16041-20000-44416	5800 W SUNSET BLVD 3rd-4th Floors	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Closed	12/22/2017 12:00:00 AM	ADDRESS	34.09728	-118.31693	TI to (E) commercial office space occupying third and fourth floors in an (E) commercial highrise building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73560	15041-20002-07369	13689 W FOOTHILL BLVD	91342	7	222B157    46	2509015027	P-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM			PC Approved	07/23/2015 12:00:00 AM	ADDRESS	34.30872	-118.43163	Change to an approved set. Modifying circuits and lighting. All changes are marked as delta 3.(((Change to approved set by modifying the panel schedule and removing panel LH.  Note, all changes are under clouded area only.)))(((TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTS NEW CONTROLS AND NEW PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 2245.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73561	19041-10000-17587	1920 E MARENGO ST	90033	14	132A223    49	5201016023	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2033.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Issued	05/10/2019 12:00:00 AM	ADDRESS	34.05739	-118.20965	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73562	19041-20000-28126	11500 W CULVER BLVD	90066	11	111B161   528	4217016001	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM	07/22/2019 12:00:00 AM		Permit Finaled	12/17/2021 12:00:00 AM	ADDRESS	34.00003	-118.4134	new fire alarm system with 71 devices and FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73563	11041-20000-17892	2170 N STRADELLA ROAD	90077	5	150B145    18	4377030011	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2011 12:00:00 AM	10/20/2011 12:00:00 AM		Permit Finaled	01/09/2014 12:00:00 AM	ADDRESS	34.11133	-118.46248	8.1 kw PV system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73564	19041-20000-31644	14610 W ISLA VISTA DR	91402	6	201B149   889	2650019062	(Q)RD2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.24741	-118.45082	PV1 PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON A NEW SFD. SYSTEM SIZE IS 3.15KW DC/2.835 KW AC. SCOPE OF WORK CONSISTS OF (9) PV MODULES WITH MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73565	15041-10000-23570	7930 N DEERING AVE	91304	3	189B105   244	2109017027	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	07/31/2015 12:00:00 AM	ADDRESS	34.21485	-118.59491	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 32828 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73566	19041-30000-33132	2049 S CENTURY PARK EAST #750	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC ENERGY ONLY FOR INTERIOR NON STRUCTURAL OFFICE T.I. AREA OF SCOPE 474SFBuilding Permit #: 19016-10000-24105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73567	08041-10001-18397	1355 N SAN PABLO ST	90033	14	133-5A225  13	5201006022	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	08/04/2010 12:00:00 AM	ADDRESS	34.06107	-118.20375	"Change from previously approved plans.  All changes indicate by DELTA 9 on the plans.  Changes include reroute feeder to panel ""1F"".  Misc. permit for feeder.  Plan check for power.*****TI in a UCLA testing lab. Electrical plan check is for power and energy.*****"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73568	15041-10000-42484	633 W 5TH ST IDF ROOMS	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/16/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/12/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	ALTERATIONS IN A IDF ROOM ON 39TH 42ND AND 45TH FLOORS.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73569	18041-20000-25635	18460 W ROSCOE BLVD	91325	12	192B125   934	2102001018	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			07/10/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.22046	-118.53569	Plan check for power and energy. Project site is the 2nd and 3rd floor of an existing medical office building. Project scope is a tenant improvement. Total lighting area = 16,648 sq. ft.Note: Building application has been generated under 18016-20000-21910	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73570	10041-10002-12355	1130 W C ST	90744	15	027B201    90	7417008038	M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			12/27/2011 12:00:00 AM	12/27/2011 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	33.77182	-118.27581	REVISED PLANS REPRESENTING AS-BUILT CONDITIONS ON SITE: REPLACE OLD 1200AA MCB SUPPLYING XFMR TA; NEW 225A MCC POWER PANEL ; ELEVATION DRAWING SHOWING EXISTING 4TH SECTION; CORRECTLY SHOWING SECTIONS ON THE ELEVATION DRAWING OF THE SERVICE EQUIPMENT; SINGLE LINE  DRAWNING ON SINGLE LINEInstalling a new HPP (High Presure Pasturation) machine for State Fish Company,  New Service and panelboards. Plan check for power and energy.  <<<<<<<CHANGES TO EXISTING APPROVED SET OF PLANS,  ALL CHANGES ARE CLOUDED>>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73571	16041-20000-37706	21100 W LASSEN ST	91311	12	201B105    88	2746004047	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.24983	-118.59356	remove hid fixtures and replace with new led indoor outdoors.  plan check for energy 54600 square feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73572	14041-20001-32919	5735 N COLUMBUS AVE	91411	4	174B145   240	2243005006	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM			PC Approved	12/11/2014 12:00:00 AM	ADDRESS	34.17491	-118.46418	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 3 STRINGS. TOTAL OF 18 MODULES.EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73573	17041-10003-18964	1830 N CHEROKEE AVE	90028	13	150A185   307	5547004044	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.10404	-118.33464	Change to approved set by adding (1) new panel and ckts on floor plan; New load also being added and updated. all changes under delta-8 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73574	13041-10000-08963	1146 S WESTWOOD BLVD	90024	5	132B153   246	4363022009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/08/2013 12:00:00 AM			PC Info Complete	04/08/2013 12:00:00 AM	ADDRESS	34.05998	-118.4446	ti, TILE T4 ONLY IN AN EXISTING RESTAURANT,  AREA IS ABOUT 385 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73575	16041-20000-13819	443 S VERMONT AVE	90020	10	135B197   660	5502009012	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2119.21	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	06/04/2024 12:00:00 AM	ADDRESS	34.06605	-118.29186	Plan check for power and energy. Change of use from Tire Shop to Self-Serve Coin Laundry. New 800A service, complete rewire including new lighting. 8,044sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73576	19041-20000-42779	11725 N AVENIDA DEL SOL	91326	12	216B121   551	2872007008	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2019 12:00:00 AM	10/21/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.28545	-118.54844	PV1.  Install 9.9 kW roof mounted grid tied PV system.  (27) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73577	15041-20002-27842	23211 W INGOMAR ST	91304	12	189B093   587	2020022025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM			PC Approved	12/31/2015 12:00:00 AM	ADDRESS	34.21204	-118.63267	Change to approved set of plans. Changes include number of modules decreased form 33 to 18 moduls and inverter model changed from  SE7600A-US to SE6000A-US. {{{{{{{Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (33) modules. Standard plan is not being used.}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73578	15041-20001-34509	16463 W BOSQUE DR	91436	5	165B137   495	2291017028	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.14544	-118.49232	EXPEDITE PER APPLICANT REQUEST(((PV1. NEW SOLAR SYSTEM ON A RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 15.2KWac.(54)MODULES-SUNEDISON MODEL#SE-F325BZC-3Y(2)INVERTERS-SOLAREDGE 7.6W INVERTER MODEL#SE7600A-US(54) OPTIMIZERS-SOLAREDGE POWER OPTIMIZER #P400)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73579	15041-10001-27150	4800 N HEAVEN AVE	91364	3	168B093   161	2074031014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	34.15756	-118.63219	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(47) REC SOLAR MODULES(1) SOLAREDGE 11400 AMP INVERTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73580	19041-10000-38100	10766 W CUSHDON AVE	90064	5	126B157  1141	4255025008	R1-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Permit Finaled	10/04/2019 12:00:00 AM	ADDRESS	34.03885	-118.42537	PV1, NEW ROOFTOP MOUNTED SOLAR SYSTEM, SYSTEM SIZE IS 6 KWac/ 6.9KWdc. SCOPE OF WORK IS 23 MODULES (SILFAB SLA-M-300) WITH OPTIMZERS (SEP320) AND A CENTRAL INVERTER (SE6000H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73581	15041-20002-33219	2975 N TIFFANY CIR	90077	5	156B149    11	4379034008	RE15-1-H-RPD	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	34.12813	-118.44633	[[[ 11/4/15 CHANGES TO APPROVED SET. CHANGES ARE CLOUDED. PLANCHECK ONLY. CHANGES THE MODULES FROM HANWA TO LG]]]Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73582	15041-10001-16824			13	162B205   118	5593018015	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/15/2015 12:00:00 AM			PC Approved	12/15/2015 12:00:00 AM	PIN	34.14017405	-118.2726462	12-15-15T-24, Changes to an approved set of plans, changes include the revision of lighting and receptacle lay out. Note changes on delta 4.  (((TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS  TO NEW PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQURE FOOTAGE 16,130.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73583	18041-20001-00864	21165 W ESCONDIDO ST	91364	3	165A107   417	2172026016	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2018 12:00:00 AM			PC Approved	01/17/2018 12:00:00 AM	ADDRESS	34.14456	-118.59449	expeditepv1install roof mounted pv system sized 10.4kw interconnected with msp with two battery back up tesla power walls.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73584	15041-20000-37335	4100 W 58TH PL	90043	8	105B181    54	4019007008	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2015 12:00:00 AM	11/05/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	33.98789	-118.34643	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) panels. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73585	19041-10000-44331	7252 N ENFIELD AVE	91335	3	186B129  1209	2121008019	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM			Reviewed by Supervisor	12/05/2019 12:00:00 AM	ADDRESS	34.20265	-118.5239	PLAN CHECK FOR PV-1 SYSTEM. SYSTEM SIZE IS 9.3KW DC. 31 MODULES (HANWHA Q-CELL Q-.PEAK-G4), WITH SOLAREDGE P370 OPTIMIZIERS. (1) SOLAREDGE OPTIMIZER SE6000H.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73586	14041-20000-23132	601 S FIGUEROA ST 46th floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM			Corrections Issued	08/25/2014 12:00:00 AM	ADDRESS	34.05076	-118.25881	TI to common area corridors and restroom on 46th floor of (E) commercial office highrise building. Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73587	18041-10000-29123	7161 WORLD WAY WEST AOA-Lighting	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	10/18/2019 12:00:00 AM		Permit Finaled	04/21/2021 12:00:00 AM	ADDRESS	33.94524	-118.41969	NEW TAXI WAY (C-14) LIGHTING AT LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73588	15041-10003-00589	12655 W BLUFF CREEK DR	90094	11	102B161  1281	4211037037	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			09/27/2017 12:00:00 AM			PC Info Complete	09/27/2017 12:00:00 AM	ADDRESS	33.97565	-118.41332	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 7 ON PLANS. SCOPE INCLUDES ADDITION OF 3 CIRCUITS TO TRASH SHOOTS AND HANDICAP LIFT. ALSO EF FEEDER CHANGE FROM AL TO CU.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73589	19041-10000-11769	888 S HOPE ST SUITE 121	90017	14	127-5A209  28	5144020196	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/02/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.0452	-118.25996	PC FOR FIRST TIME TENANT RESTAURANT (THE HABIT) IN A HIGH RISE MIXED USED. SCOPE INCLUDES NEW PANELS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 2542 SQ. FTB# 19016-10000-09282	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73590	14041-20000-15587	6333 W 3RD ST	90036	4	138B177  1126	5512003030	C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM			PC Approved	06/12/2014 12:00:00 AM	ADDRESS	34.07157	-118.36014	PC FOR T24 ENERGY ONLY. INTERIOR T.I. TO CANDY SHOP. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73591	16041-10000-41211	19701 W SHERMAN WAY	91306	3	183B117    52	2115019019	C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	Commercial			11/22/2016 12:00:00 AM	11/22/2016 12:00:00 AM		Permit Finaled	03/02/2017 12:00:00 AM	ADDRESS	34.20129	-118.56266	PC for title 24, outdoor. Remove HID fixtures and replace with new LED fixtures. Total sqft = 17225.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73592	18041-20000-39505	13455 W MAXELLA AVE	90292	11	105B153    29	4230005041	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	03/03/2021 12:00:00 AM	ADDRESS	33.9867	-118.44159	new 2000 amp service to an exisitng commercial building.  plan check for power only.  distribution board only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73593	16041-10000-30983	20248 W WYANDOTTE ST	91306	3	186B113   827	2114018215	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.20258	-118.57475	PC FOR PV SYSTEM. ROOF MOUNTED MICROINVERTER. USING TOTAL OF 43 MODULES AND ENPHASE M250	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73594	15041-10000-08938	3501 E VALLEY BLVD	90031	1	136-5A227  63	5211021901	OS-1XL	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	12/21/2016 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.06562	-118.20179	NEW BATH HOUSE, NEW POOL HOUSE, PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73595	13041-10001-33010	16528 W PLUMMER ST	91343	12	198B137    74	2676001008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.24275	-118.4926	Expedited RSES plan check per applicant request.[[][][]]PV1, Install 3.75 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(1)Transformerless inverter(s): SolarEdge SE3800A-US. (15) modules: Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73596	16041-20000-29931	9301 N OAKDALE AVE 3rd Floor-Corridor	91311	12	198B113   113	2761040019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/23/2016 12:00:00 AM	08/23/2016 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	ADDRESS	34.23936	-118.56702	Plan check for energy only. Install new lighting (incl. emergency) on 3rd floor corridor of existing commercial building. 265sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73597	11041-10000-27101	5655 N SHIRLEY AVE	91356	3	174B117   692	2153026021	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2011 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	03/07/2012 12:00:00 AM	ADDRESS	34.17445	-118.55804	Plan check 18.56KW roof mounted photovoltaic system single family dwelling. Arrays mounted on main house and detached garage. Inverters located at detached garage. Derate main OCPD from 200A to 150A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73598	13041-10002-04818	680 S BERENDO ST	90005	10	132B197   130	5094008010	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			06/03/2014 12:00:00 AM			PC Approved	06/03/2014 12:00:00 AM	ADDRESS	34.06064	-118.294	REVISIONS TO PERMITTED SET OF PLANSPROPOSED 171 UNIT APARTMENT W/ GARAGE. 6 STORIES OF TYPEIIIA CONSTRUCTION W/ 3 LEVELS (2 BASEMENT AND 1ST FLOOR) OF TYPE I GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73599	18041-10000-24605	1725 N ARGYLE AVE	90028	13	148-5A189  68	5546030002	C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	08/17/2018 12:00:00 AM		Permit Expired	01/12/2023 12:00:00 AM	ADDRESS	34.10252	-118.32534	NEW FIRE ALARM PANEL WITH (13) FIRE ALARM DEVICES TO A LOADING DOCK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73600	15041-20001-13675	6250 N TOPANGA CANYON BLVD BldgF#1530	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/01/2015 12:00:00 AM			PC Approved	09/01/2015 12:00:00 AM	ADDRESS	34.18498	-118.60554	09/01/2015 Changes to an approved set of plans. Changes include the relocation of outlets in the Open Area.*****Previous Work Description*****Plan check for 1st time tenant at Westfield Village at Tapanga(Bldg F #1530) for Credit Union. Total area: 2,000 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73601	17041-10000-03813	15246 W SUNSET BLVD WEST	90272	11	129B125   824	4412002008	C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2627.06	Electrical	Electrical	Commercial			02/06/2017 12:00:00 AM	04/18/2017 12:00:00 AM		Permit Finaled	01/09/2018 12:00:00 AM	PIN	34.04659055	-118.52521084	PC FOR FIRE DAMAGE REPAIR OF BUILDING. SMALL CAFE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73602	19041-10001-25920	17535 W HORACE ST	91344	12	210B129   640	2712007028	RE9-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	11/26/2019 12:00:00 AM	ADDRESS	34.26986	-118.51642	CHANGES TO AN APPROVED PLANS.  ADDITION OF 3 SOLAR PANELS FOR A TOTAL OF 43 PV PANELS AND THE TOTAL SYSTEM RATING OF 12.25KW. ((PV1. Install 11.4 kWDC AND 9.69KWAC roof mounted grid tied PV system. (40) modules with P320 OPTIMIZERS, (1) 11.4 KW (SE11400H-US) rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73603	16041-10000-13062	1150 S OLIVE ST SUITE1375	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	07/18/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 1830.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73604	18041-10000-14572	6400 N LAUREL CANYON BLVD	91606	2	180B165   677	2322007057	C2-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.18693	-118.3963	PC FOR BANK TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA 7390  SQ.FT  109 UNITS INDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73605	15041-20000-02169	6330 W SAN VICENTE BLVD	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/23/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.06116	-118.36804	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. OFFICES.  1183 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73606	18041-20001-42775	3827 S FRANCES AVE 1-18	90066	11	111B153   527	4235002015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2722.01	Electrical	Electrical	Apartment			10/01/2019 12:00:00 AM			PC Approved	10/01/2019 12:00:00 AM	ADDRESS	34.00135	-118.43648	10-01-20198 Changes to an approved set of plans, Changes include remove inverter for emergency lighting and installed 90 minutes battery back up for Emergy lights. All changes has been clouded and apply to delta 2 and 3. Plan check only. Permit fees covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73607	18041-10000-16893	333 S HOPE ST 38TH FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	Yes	2075.02	Electrical	Electrical	Commercial			05/08/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLAN CHECK FOR POWER AND ENERGY FOR TI - FOR EXISTING OFFICE SPACE. NEW CONNECRTED LOAD >400A. TOTAAL AFFECTED AREA = 15906 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73608	15041-20000-32313	15900 W VALLEYVIEW CT	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			09/30/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.30584	-118.47951	Plan check for power and energy for T.I. clen room renovation Phase 3 of 3. Total area for phase 3 of 3: 9,043 sqft. Note: refer to Building permit # 15016-20000-20387	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73609	17041-10001-23919	3201 S HOOVER ST 8A-1	90007	9	121-5A201 201	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM			PC Info Complete	01/05/2018 12:00:00 AM	ADDRESS	34.02548	-118.28442	PC FOR REVISIONS TO APPROVED SET UNDER DELTA 2 & 3. SCOPE INCLUDES REVISION TO LOAD CALCS DUE TO REDUCTION TO MAIN BREAKER  (FROM 600A TO 400A) DUE TO FIELD CONDITIONS. PC for power and energy for new restuarant TI. Load over 400 A. Total sqft 4870  .Building PC 17016-10000-14043.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73610	19041-20001-46880	9317 N BRIGHTWOOD CT	91325	12	198B133   255	2692022020	RE9-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2019 12:00:00 AM	11/27/2019 12:00:00 AM		Issued	11/27/2019 12:00:00 AM	ADDRESS	34.23992	-118.50334	PV1. INSTALL 8.68 KW DC PV SYSTEM WITH (28) MODULES/OPTIMIZERS AND (1) INVERTER (SE7600)NOTE: INSPECTION FEE UNDER ONLINE PERMIT 19041-90000-46880	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73611	16041-30000-20004	749 S BROADWAY 2ND FLR	90014	14	127-5A209  96	5144014028	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/07/2016 12:00:00 AM	05/03/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.04418	-118.25458	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  SCOPE TO BE PERFORMED IN THE SECOND FLOOR.  TOTAL SQUARE FOOTAGE 22585.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73612	17041-10000-27199	11457 N SAN FERNANDO ROAD	91340	7	213B153   108	2616018029	M1-1-CUGU	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	Commercial			08/04/2017 12:00:00 AM	08/04/2017 12:00:00 AM		Issued	08/04/2017 12:00:00 AM	ADDRESS	34.27789	-118.43489	TITLE 24 PLAN CHECK FOR REPLACEMENT OF (6) EXISTING FIXTURES AND REPLACING WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 16800 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73613	17041-20000-00676	23239 W DOLOROSA ST	91367	3	174B093   588	2044001040	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.17021	-118.63358	Plan check for a PV1 roof-mounted PV system. System size is 14.3 kWac and consists of (51) modules, (51) micro-inverters, and (1) load center.$0 permit fee per State Senate Bill SB1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73614	18041-10000-22007	7026 N TOPANGA CANYON BLVD	91303	3	183B101   272	2138002041	(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	06/13/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.19811	-118.60562	INSTALL A NEW FIRE ALARM (SPRINKLER MONITORING) SYSTEM WITH 55 DEVICES IN THE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73615	15041-10000-37865	8901 N BRADLEY AVE	91352	6	195B173   629	2408037016	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/10/2015 12:00:00 AM	11/10/2015 12:00:00 AM		Permit Finaled	01/26/2016 12:00:00 AM	ADDRESS	34.23073	-118.37731	T-24, TI TO A COMMERCIAL WAREHOUSE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 47,371.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73616	15041-20001-34250	2500 S SIGNAL ST BERTH 58-59, 60	90731	15	018B201   298	7440026903		Harbor	PORT OF LOS ANGELES			2961.00	Electrical	Electrical	Commercial			03/22/2017 12:00:00 AM			PC Approved	04/01/2017 12:00:00 AM	ADDRESS	33.72053	-118.27222	THIS APPLICATION IS FOR PLAN CHECK FOR BERTH 60 AND PERMIT FOR BERTH 59 AND 60. DUE TO BUILDING PERMIT FILE FOR SINGLE PERMIT TO COVER BERTH 58-60 THIS APPLICATION NOW COVERS ENTIRE SCOPE OF WORK ADDRESS RANGE. MASTER PERMIT COVERS BERTH 58SEE INSPECTION FEES FOR PERMIT ISSUANCEREFER TO APPLICATION 15041-10000-34252 FOR PC FEES COLLECTED FOR BERTH 59THE BUILDING PERMIT FOR THIS SCOPE OF WORK 15016-10000-21404	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73617	19041-10000-42045	6344 W FOUNTAIN AVE	90028	13	144B185   166	5533005057	C2-1-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/19/2021 12:00:00 AM		Permit Finaled	05/29/2024 12:00:00 AM	ADDRESS	34.09416	-118.32835	FULL PC FOR AN ADDITION TO AN EXISTING ELECTRICAL SYSTEM, SCOPE OF WORK INCLUDES A NEW 4000A SERVICE 480/277 (3P, 4W) THAT IS INTERCONNECTED TO AN EXISTING SWITCHBOARD AND A NEW 4000A SWITCHBOARD. THE NEW 4000A SWITCHBOARD FEEDS VARIOUS TRANSFORMERS AND VARIOUS DISTRUBUTION PANELS THAT SUBFEED SUBPANELS. TOTAL AFFECTED AREA IS 52,247 SQFT. B# 19014-10000-05376	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73618	17041-10000-37499	3109 W BEVERLY BLVD	90057	13	138A201   209	5156010010	C2-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM	10/30/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.0721	-118.28246	PC FOR COFFEE SHOP TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW CIRCUITS LIGHTS EQUIPMENT AND RECEPTACLES. TOTAL AFFECTED AREA 760SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73619	12041-20000-27122	14117 W HUBBARD ST # 7 & # 7A	91342	7	219B153   199	2508027019	(Q)C4-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM	11/29/2012 12:00:00 AM		Permit Finaled	01/28/2013 12:00:00 AM	ADDRESS	34.29849	-118.44081	first time tenant for core and shell.  Power and T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73620	14041-20001-22193	16426 W KNOLLWOOD DR	91344	12	219B137    59	2609016002	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM			PC Approved	09/10/2014 12:00:00 AM	ADDRESS	34.29717	-118.49574	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.4KW INTERCONNECTED WITH MSP.(46) KYOCERA KD255GX-LFB3 MODULES(2) POWER ONE AURORA PV1-4.2 TRANSFORMERLESS INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73621	16041-20000-08768	1500 N GILCREST DR	90210	4	147B165   360	4352009054	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			03/14/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Expired	05/04/2018 12:00:00 AM	ADDRESS	34.09796	-118.40202	PV1.  Install 20.0 kW AC roof-mounted PV system.  (2) 10000 W inverters w/ (68) modules.Note: $0.00 permit fees due Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73622	19041-10000-01867	6600 S MCKINLEY AVE	90001	9	105B205  1262	6007015006	M3-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			01/16/2019 12:00:00 AM	01/16/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	33.9803	-118.26127	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73623	13041-10002-35451	1610 N ALVARADO ST	90026	13	142-5A209 246	5419002012	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/14/2014 12:00:00 AM	ADDRESS	34.0837	-118.25953	Expedited RSES plan check per applicant request.{{PV1, Install 3.75 kw DC roof-mounted solar array, interconnect with main service for a one story house. (1)Transformerless inverter(s): SOLAREDGE SE 3800A-US, (15)Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73624	15041-10000-13477	4700 W WESTERN HERITAGE WAY	90027	4	162B201     5	5593002***	OS-1XL	Central	Hollywood	Los Feliz	YES	9800.09	Electrical	Electrical	Public Safety Only			05/05/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	07/26/2016 12:00:00 AM	ADDRESS	34.14865	-118.28197	REPLACING FIRE WARNING SYSTEM AT AUTRY MUSEUM OF THE AMERICAN WEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73625	18041-10001-46698	1660 W RIVERSIDE DR	90031	13	144B213    13	5445001037	C2-1VL-RIO, P-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley			1972.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	08/20/2019 12:00:00 AM	ADDRESS	34.09469	-118.24235	DELTA 2 CHANGES TO AN APPROVED SET. CHANGES TO HVAC EQUIPMENT LOCATION, LIGHTING, T-24  AND FIXTURE SCHEDULE. ALL CHANGES ARE CLOUDED UNDER DELTA 2.   Original Scope: (FULL PLAN CHECK FOR POWER AND ENEGY FOR - INTERIOR  TI OF COMMERCIAL OFFICE BUILDING, NEW STORAGE ROOM (ADDITION) NON HIGHRISE BUILDING - TOTAL CONNECTED LOAD >400A WITH 8542 SF OF AFFECTED AREA.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73626	18041-30000-01153	2029 S CENTURY PARK EAST #438	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	03/07/2018 12:00:00 AM	ADDRESS	34.05956	-118.41375	Plan check for Title 24 only  in existing high-rise building. Total area: 1145 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73627	17041-20000-23774	15821 W VENTURA BLVD Suite 425	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.15584	-118.47812	Plan check for energy only. TI to existing office suite 425. New lighting - 507sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73628	10041-20000-24893	1312 E 7TH ST Bldg B2-Unit #21	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	12/17/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.03615	-118.24064	"Plan check T24 Energy for tenant improvement to interior of storage room (Unit #21) in Building B2. Title 24 only. Existing branch circuits.""COMPLY WITH DEPARTMENT ORDER effective date06/21/2006. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73629	16041-30000-25332	3831 S HUGHES AVE 7th Floor	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.02242	-118.39823	Plan check for Title 24 only. Project site is the 7th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,495 sq. ft.Note: Building application has been generated under 16016-10000-12414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73630	17041-20000-02696	14660 W ARMINTA ST	91402	6	189B149   524	2210021015	M2-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.21328	-118.45279	ti to an existig commercial space, replacing existing fire damage equipment.  adding new lighitng new controls to existing panels.  total square footage 8490.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73631	17041-20001-29719	11241 N RANETTO PL	91342	7	210B181    95	2550021007	RE11-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.27421	-118.34648	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 7.6 kWac and consists of (1) inverter, (27) modules, (1) load center, and (1) Tesla Powerwall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73632	15041-20000-02664	12500 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73633	16041-10000-23369	19001 S HARBORGATE WAY 2ND FLR	90501	15	060B193   440	7351021043	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/05/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	33.85763	-118.30375	T-24, PC FOR ENERGY ONLY. T.I.  TO AN EXISTING OFFICE SPACE ON THE 2ND FLOOR OF AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES ADDING/REPLACING LIGHTING FIXTURES AND RECEPTACLES. TOTAL AFFECTED AREA IS 12662 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73634	14041-10000-00915	726 E 12TH ST #101	90021	14	123A211    22	5132012060	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	03/05/2014 12:00:00 AM	ADDRESS	34.03314	-118.25248	Ti in retail. EPC is for T24. Existing emergency and ckt.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73635	15041-20000-19443	13162 W WELBY WAY	91606	2	180B157   166	2326011005	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2015 12:00:00 AM	06/22/2015 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.19288	-118.42021	PV1 SFD. TOTAL SYSTEM SIZE 5KW MICROINVERTERS. USING NON STANDARD PLAN. TOTAL OF 18 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73636	19041-20000-43771	9135 N TAMPA AVE	91324	12	198B117   181	2761037006	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/28/2019 12:00:00 AM	04/09/2020 12:00:00 AM		Permit Finaled	04/28/2021 12:00:00 AM	ADDRESS	34.23623	-118.55378	New 4000A 480Y/277V 3ph-4w service, power, and distribution for shell building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73637	16041-20000-11761	11011 W OTSEGO ST	91601	2	171B173   834	2353007033	R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			04/05/2016 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.16308	-118.37103	Plan check for power and energy. Project site is a new 144-unit, 5-story apartment building over 2 levels of basement parking. Work includes a 3,000-amp service. Total lighting area = 122,863 sq. ft.Note: Building application has been created under 15010-20000-04055	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73638	12041-10000-09866	401 S ANDERSON ST	90033	14	126A219    25	5171010005	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			05/01/2012 12:00:00 AM			PC Approved	05/04/2012 12:00:00 AM	PIN	34.04062024	-118.22578512	INSTALLATION OF 2 EA WALK-IN COOLERS WITH LIGHTING, PLAN CHK IS FOR TITLE 24 WITH EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73639	17041-10002-18656	2915 N CORDA LANE	90049	11	156B137    57	4490006039	RE15-1-H	South Valley	Brentwood - Pacific Palisades		YES	2623.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM			PC Approved	07/26/2018 12:00:00 AM	ADDRESS	34.12618	-118.48856	PC for a lost set of plans. Installation of (1) new 200A load center with (1) 5.8 kVA  Tesla AC Powerwall battery for an existing PV system.Note: PLAN CHECK ONLY. PERMIT UNDER PCIS #17041-10000-18656	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73640	14041-10001-09420	223 E 111TH PL	90061	8	087A205    30	6073018020	R2-1	South Los Angeles	Southeast Los Angeles			2411.10	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	33.93404	-118.27082	(((EXPEDITE FEES)))P V1 ROOF MOUNTED TRANSFORMERLESS SYSTEM W/ OPTIMIZERS. TOTAL SYSTEM SIZE 3.0KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73641	17041-20000-14776	1713 S WESTERN AVE	90006	10	126B193  1421	5073012034	[Q]C2-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			05/04/2017 12:00:00 AM			PC Info Complete	05/04/2017 12:00:00 AM	ADDRESS	34.04227	-118.30925	TI TO RETAIL STORE. EYEGLASS AND CONTACT LENSE FITTING ONLY. NO OPTOMOTRY IN THIS TENANT. PROVIDING NEW LIGHTING AND WIRING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73642	14041-10000-01226	1458 S SAN PEDRO ST # 151	90021	14	123A209   397	5132027***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/15/2014 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	PIN	34.03045627	-118.25434986	PLANCHECK FOR T24 ENERGY ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. ALL WORK IS INDOORS. 765 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73643	16041-20000-25285	21015 W LANARK ST	91304	3	189B105    57	2109007008	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	07/19/2016 12:00:00 AM		Permit Finaled	08/24/2016 12:00:00 AM	ADDRESS	34.21759	-118.59143	Plan check for PV roof mounted system. System size: 8.6kW with 17 modules and 2 inverters(3.6kW and 5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73644	13041-10000-27243	678 S ALVARADO ST	90057	1	132A203    89	5141002900	C2-4	Central	Westlake	Westlake South		2089.03	Electrical	Electrical	Apartment			10/22/2013 12:00:00 AM			PC Info Complete	07/12/2016 12:00:00 AM	ADDRESS	34.05712	-118.27618	FULL PLAN CHECK FOR A 5-STORY, 82 UNITS APARTMENT, MIXED BUILDING (~7000 SQ FT FOR RETAIL SPACE). PLAN CHECK WILL BE FOR POWER AND ENERGY. 4000A UNDERGROUND SERVICE; NOT LOCATED IN METHANE ZONE BASED ON INFORMATION PROVIDED ON ZIMAS. BUILDING PERMIT EXIST UNDER 13010-10000-02100. FIRE ALARM PLAN WILL BE FILED SEPARATELY, DO NOT PLAN CHECK UNDER THIS PC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73645	18041-20002-32245	731 N LA CIENEGA BLVD	90069	5	141B173   334	4337003061	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.08449	-118.3767	Plan check for Title 24 only in existing space T.I. retail space. Total area: 452 sq ft. Plan check only, permit covered under Application Number: 18041-20000-32245B#18041-20000-32245	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73646	15041-20000-19483	950 S BROADWAY	90015	14	126A209    41	5139002022	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/22/2015 12:00:00 AM			PC Info Complete	06/10/2016 12:00:00 AM	ADDRESS	34.04113	-118.25698	PLANCHECK FOR POWER AND ENERGY. ADAPTIVE REUSE OF EXISTING BUILDING: CONVERT EXISTING BLDG TO 30 RESIDENTIAL UNITS AT FLOORS 2-7; RESIDENTIAL ACCESSORY DECK AT ROOF. FIRST FLOOR TO REMAIN AS COMMERCIAL USE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73647	13041-10000-18192	1250 S LA CIENEGA BLVD	90035	5	132B173  1178	5087003014	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			07/10/2013 12:00:00 AM	10/04/2013 12:00:00 AM		Permit Finaled	02/07/2014 12:00:00 AM	ADDRESS	34.05438	-118.37595	Plan check power and energy for tenant improvement for Joanne retail store. Existing service, new panels, equipment, and branch circuits. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73648	14041-10000-20028	2764 W ROWENA AVE	90039	4	150A207    31	5434032013	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Commercial			07/25/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Finaled	03/12/2015 12:00:00 AM	ADDRESS	34.10727	-118.26419	PLANCHECK FOR POWER AND ENERGY. UPGRADE SERVICE TO 600 AMPS. TENANT IMPROVEMENT FOR LIGHTING AND HVAC. 2013 T24 COMPLIANCE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73649	17041-20000-37881	23412 W MAESTRO PL	91304	12	186B093    53	2027001032	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Re-Activate Permit	08/23/2018 12:00:00 AM	ADDRESS	34.20975	-118.63895	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73650	17041-20000-40027	273 N MABERY ROAD	90402	11	123B129   916	4410005001	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Expired	09/28/2023 12:00:00 AM	ADDRESS	34.02955	-118.5143	Install 19.4 kWh energy storage system in SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73651	15041-10000-15140	375 S SALTAIR AVE	90049	11	132B141   694	4404022019	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2015 12:00:00 AM	09/03/2015 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.05602	-118.47427	NEW SFD WITH 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73652	15041-10000-37361	6600 W SUNSET BLVD	90028	13	147A185    65	5547024032	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.09782	-118.33334	PC FOR POWER AND ENERGY. FIRST TIME TENANT RESTURANT. 2-STORY BUILDING. TOTAL AREA 6150 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73653	16041-20000-45603	15260 W VENTURA BLVD 1810	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM			PC Info Complete	12/29/2016 12:00:00 AM	ADDRESS	34.15356	-118.4658	ti to an existing commercial building high rise.  addig new lighitng new controls to existing panels.  plan check for energy only.  total square footage 3646  scope of work to be in suite 1810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73654	10041-20001-05864	1605 N GLENDALE BLVD	90026	13	142-5A209 200	5423009026	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM			PC Approved	06/28/2012 12:00:00 AM	ADDRESS	34.08393	-118.26031	comply with green building code	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73655	15041-10000-33887	900 N CAHUENGA BLVD Suite B	90038	13	144B185  1190	5533019012	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	05/24/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.0873	-118.32862	Title 24 plan check only.  Total area = 6,524 sq. ft.    T.I. to office space including new lighting and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73656	14041-20000-14397	19918 W ARCHWOOD ST	91306	3	180B113   253	2134010020	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.19179	-118.56735	PV1.  Install 4.08 kW roof-moutned utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73657	17041-10000-39223	1160 E 11TH ST	90021	14	123A213   177	5132015034	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.03108	-118.24536	REPLACE OUTDOOR LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73658	13041-10000-32158	431 S BROADWAY	90013	14	129A211    39	5149026003	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/18/2013 12:00:00 AM			PC Info Complete	05/05/2014 12:00:00 AM	ADDRESS	34.04886	-118.25023	pc for power only. existing builidng. new 1200A switchgear. not methane.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73659	19041-10000-00800	11233 N BORDEN AVE #9	91331	7	210B161   684	2536010***	(Q)RD2-1-CUGU, (Q)RD3-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.2737	-118.4062	PV1. NEW ROOF MOUNTED SOLAR SYSTEM USING (17) AC MODULES ON EXISTING RESIDENTIAL HOME. TOTAL SYSTEM SIZE IS 5.56KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73660	10041-10000-01721	2100 E PACIFIC COAST HWY ETD	90744	15	033B213    10	7428007003	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		2941.20	Electrical	Electrical	Commercial			02/01/2010 12:00:00 AM	05/26/2011 12:00:00 AM		Permit Finaled	04/30/2012 12:00:00 AM	ADDRESS	33.79122	-118.23692	INSTALLATION OF A STATE OF CALIFORNIA PERMITTED PRE-MANUFACTURED BUILDING TO FUNCTION AS AN EMPLOYEE OFFICE FOR THE TESORO REFINERY, AND NEW CANOPY AND A STORAGE SHED.  >>>>>> ETD AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73661	15041-20000-30671	2724 E CINCINNATI ST	90033	14	127-5A225  17	5177032016	RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2037.20	Electrical	Electrical	1 or 2 Family Dwelling			09/16/2015 12:00:00 AM	09/16/2015 12:00:00 AM		Permit Finaled	10/06/2015 12:00:00 AM	ADDRESS	34.04551	-118.20273	PV 1,  rooftop solar system,  3.118 kWAC, transformerless. (14) modules: TSM-255 PD05.05(1) Inverter: PVI-3.0-OUTD-S-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73662	15041-10000-16437	7946 W OCEANUS DR	90046	4	153B173   914	5569025023	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	10/10/2015 12:00:00 AM	ADDRESS	34.11225	-118.36784	PV1, INSTALL 12.825 KW DC ROOF-MOUNTED ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAAMILY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. PERMIT FEE IS DUE TO SENATE BILL 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73663	15041-20000-29012	19809 W PRAIRIE ST	91311	12	198B113   115	2761040023	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/02/2015 12:00:00 AM	09/23/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.23925	-118.56529	Installation of new roof mounted solar PV array.  This is a feed-in-tarif project.  Total system size = 140 kWac.  540 PV modules are being connected to 7 inverters.NOTE: FEES $0 DUES TO SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73664	16041-10002-23845	2189-2195 E WHITTIER BLVD	90023	14	124-5A221 121	5183021023	R3-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.50	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	01/11/2019 12:00:00 AM		Permit Finaled	01/15/2019 12:00:00 AM	ADDRESS	34.03614	-118.21937	SUPPLEMENTAL FOR CHANGES TO APPROVED SET - CHANGES INCLUDE THE REMOVAL OF PANELS CH, CL AND BL, AND ADDITION OF NEW TRANSFORMER RATHED AT 150KVA 240/208/120V	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73665	18041-10000-30073	18500 W BRYMER ST	91326	12	213B125   218	2872018027	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	08/09/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.2818	-118.53525	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 7.6KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 33 MODULES AND (P320 OPTIMIZERS)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73666	17041-20001-38935	16188 W ROYAL OAK ROAD	91436	5	162B141   272	2286013015	RE15-1-H	South Valley	Encino - Tarzana	Encino	Yes	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2018 12:00:00 AM			PC Approved	04/26/2018 12:00:00 AM	ADDRESS	34.13958	-118.48337	Supplemental for lost set of plans:Plan check for the addition of a battery back-up system to an existing roof-mounted PV system.Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73667	13041-20000-02300	20934 W TULSA ST PV-1	91311	12	210B109   368	2706005003	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.26797	-118.59016	"PV-1. Plan check for PV SFD. Horst Residence. 19.62 kW. PLEASE INCLUDE MONITORING SYSTEM DURING ""INSPECTION"" PAY PERIOD."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73668	10041-20000-01322	12507 W VENTURA BLVD	91604	2	162B165   192	2375018013	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	02/17/2010 12:00:00 AM		Permit Finaled	03/15/2010 12:00:00 AM	ADDRESS	34.1429	-118.40557	T.I in pet store. This plan check is only title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73669	11041-10000-25101	1632 W BELLEVUE AVE	90026	13	136-5A207  28	5404014900	OS-1XL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			11/23/2011 12:00:00 AM	11/23/2011 12:00:00 AM		Permit Finaled	06/14/2013 12:00:00 AM	ADDRESS	34.07014	-118.26077	install new 400 amp 120/240 volt electrical service. in metane area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73670	13041-20000-27236	11038 N CHIMINEAS AVE PV1	91326	12	210B125   466	2715013016	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/28/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.271	-118.52847	PV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE. NON STANDARD PLAN. MICROINVERTERS. SYSTEM SIZE: 7.0 kW.(28) CANADIAN SOLAR 250 MODULES(28) ENPHASE 215 MICROINVERTERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73671	18041-10000-26963	1537 N MCDONALD AVE	90744	15	036B205   680	7414030024	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.79399	-118.27222	INSTALL A NEW 3.84KW ROOF MOUNTED PV SYSTEM WITH 13 MODULES ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73672	16041-10001-02708	4742 S LA VILLA MARINA APT 000J	90292	11	105B153   134	4224022***	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	03/22/2016 12:00:00 AM		Permit Finaled	06/09/2016 12:00:00 AM	ADDRESS	33.98158	-118.43566	PV2, PC for a new solar system on existing commercial building (apartment unit). Total system size is 3.8KWac. (10)Modules-SPR x21-345(1)inverter-Sunnyboy SMA SE3800TL-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73673	12041-20000-12483	22931 W MARIANO ST	91367	3	171B097    20	2042008055	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2012 12:00:00 AM	06/18/2012 12:00:00 AM		Permit Finaled	07/19/2012 12:00:00 AM	ADDRESS	34.16847	-118.62652	Photovoltaic system on roof of single family dwelling using enphase inverters.  Include service upgrade and combining load cienter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73674	16041-10000-27408	570 S ALAMEDA ST	90013	14	126A215   174	5164001009	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	08/03/2016 12:00:00 AM		Permit Finaled	08/29/2016 12:00:00 AM	ADDRESS	34.03943	-118.23812	Plan check for T-24 only.  Remove HID fixtures and replace with new LED fixtures. Affected area: 19,112 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73675	18041-10000-01031	3700 W WILSHIRE BLVD	90010	10	132B193    66	5093006019	C4-2, CR-2, P-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	07/11/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.06147	-118.30682	**Zero permit fee per AB-1414/ SB-1222**Install New PV system on a commercial building, 133.2kW AC system. Scope includes (4) inverters SE33.3KUS, (456)modules with (228)optimizers, (1) 200A combiner panel. PV system will connect to (E) 4000A, 480/277V service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73676	17041-10000-06503	9576 N LEV AVE	91331	6	201B157   780	2621026017	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	03/08/2017 12:00:00 AM	ADDRESS	34.24405	-118.42653	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. SCOPE INCLUDES REFEEDING TWO EXISTING STRING ARRAYS TO NEW INVERTER AND ADDING A NEW 10 MODULES STRING ARRAY.  (10)MODULESAXITEC AXIPOWER AC-265P/156-60S(1)INVERTER-FRONIUS 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73677	19041-10001-02774	10250 W SANTA MONICA BLVD #2770	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM			PC Approved	05/21/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Change to an approved set by modifying the lighting plan. All changes under delta-5 only.(((FULL PLAN CHECK FOR FIRST TIME TENANT (WUSHILAND BOBA) - TOTAL AFFECTED AREA = 826SF)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73678	18041-10000-07077	1850 N CHEROKEE AVE	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM			PC Approved	12/17/2018 12:00:00 AM	ADDRESS	34.10481	-118.33464	Void application	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73679	13041-20000-01173	9154 N SEPULVEDA BLVD	91343	7	198B145   317	2656023028	C2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	04/16/2013 12:00:00 AM	ADDRESS	34.23733	-118.46731	800 amp service upgrade to an existing commercial building.  Full Plan Check.  Shell only for new tenant space with ESTIMATED Load only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73680	17041-30000-39703	11633 W SAN VICENTE BLVD #210	90049	11	132B145   475	4401019013	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	03/19/2018 12:00:00 AM	ADDRESS	34.05413	-118.46325	Plan check for power and energy for Dental office T.I. Total area: 921 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73681	18041-10000-34162	16221 W MULHOLLAND DR	90049	5	159B137   413	2293017001	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	09/26/2018 12:00:00 AM	ADDRESS	34.13027	-118.48588	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73682	16041-20000-30532	9210 N DORRINGTON AVE	91331	6	198B153   744	2642027009	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	01/03/2017 12:00:00 AM	ADDRESS	34.23764	-118.4363	PV1. ROOFMOUNTED SOLAR SYSTEM . SYSTEM SIZE: 11.445 KW.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73683	15041-10000-04448	1552 N CAHUENGA BLVD	90028	13	148-5A187 343	5546012400	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.09946	-118.32934	PC for T24 only.  Change of use from retail to restaurant. Total area = 742 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73684	16041-20000-39729	15551 W HARVEST ST	91344	12	213B145   128	2662001010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	02/28/2017 12:00:00 AM	ADDRESS	34.27832	-118.4714	Plan check for roof-mounted solar pv system with DC battery backup system (SolarEdge/Tesla Power Wall) for SFD.Interconnect with 225A MSP.7.6kW ungrounded system. (22) 285W pv modules. Each module has a 300W power optimizer.(1) 3.3kW backup battery.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73685	19041-10000-16156	8500 N BALBOA BLVD #140	91325	12	192B133    33	2689019019	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	08/05/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.22485	-118.50045	PLAN CHECK FOR T24 ONLY. OFFICE TENANT IMPROVEMENT OF (E) OFFICE SPACE WITH (E) MEZZANINE.  TOTAL AREA APPROX. 11,621 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73686	15041-10001-23151	1550 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM			PC Info Complete	09/01/2016 12:00:00 AM	ADDRESS	34.09932	-118.32644	09/01/16Changes to an approved set of plans. All changes are made under delta 9. Changes include  changing out conductors from copper to aluminum,  adding a pump, and condensing unit on the floor plans, revisions to panel schedules, transformer Z%, and the available fault current at panelboards. (((((((PC FOR POWER AND ENERGY. FIRST TIME TENANT. FITNESS BUILDING. TOTAL AREA 38243 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73687	11041-10000-26824	5401 S FIGUEROA ST #8-9	90037	9	108B201  1379	5001024034	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM	05/17/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	33.99309	-118.28287	PLAN CHECK POWER AND ENERGY FIRST TIME TENANT 7-ELEVEN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73688	11041-10000-15322	421 S BIXEL ST	90017	1	132A207   163	5152003001	CW	Central	Westlake			2092.00	Electrical	Electrical	Commercial			07/21/2011 12:00:00 AM			PC Approved	07/21/2011 12:00:00 AM	ADDRESS	34.05622	-118.26088	TI TO AN EXISTING CONFERENCE ROOM SPACE IN A 4-STORY MIXED-USE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73689	10041-20000-19819	15543 W ROXFORD ST	91342	7	225B145   265	2501002062	[Q]MR1-1VL-K	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			10/06/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Finaled	03/31/2011 12:00:00 AM	ADDRESS	34.31232	-118.47097	PLAN CHECK T24 ENERGY GENERAL/EMERGENCY LIGHTING FOR NEW COMMERCIAL BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73690	14041-20000-27997	150 E 61ST ST	90003	9	105B205   653	6006010002	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2014 12:00:00 AM	10/31/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	33.98405	-118.27207	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73691	10041-10000-12968	1150 E IMPERIAL HWY	90059	15	084B209   105	6084031026	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	Commercial			07/07/2010 12:00:00 AM			Reviewed by Supervisor	08/02/2010 12:00:00 AM	ADDRESS	33.9293	-118.2549	NEW RETAIL STORE  & CAR WASH at a  SHELL gas station; dispensers sre existing	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73692	16041-10000-03631	17475 W REVELLO DR	90272	11	126B117   553	4416021035	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/01/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.04037	-118.55723	PC FOR 7.6KW AC USING CENTRAL INVERTER SYSTEM. SYSTEM USES POWER OPTIMIZERS. TOTAL OF 34 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73693	14041-10000-11440	6006 S BUCKLER AVE	90043	8	105B181   632	4003009002	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	33.98505	-118.35166	PV1 3.75KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(15)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73694	17041-10000-16849	9901 N LURLINE AVE	91311	12	201B109    59	2741002006	R3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM			Corrections Issued	05/22/2017 12:00:00 AM	ADDRESS	34.25058	-118.58431	TENANT IMPROVEMENT OF COMMUNITY CLUBHOUSE. pc for t24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73695	15041-20000-18403	9325 N LA SHELL DR	91042	7	198B201   401	2572048029	RE11-1-H	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	08/05/2015 12:00:00 AM	ADDRESS	34.23779	-118.27601	FEE IS $9.51 DUE TO 2012 STATE SENATE BILL 1222PV1 SFD. TOTAL SYSTEM SIZE 11KW AC USING 2 CENTRAL INVERTERS. SYSTEM USES POWER OPTIMIZERS. TOTAL OF 40 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73696	16041-10001-32802	10250 W SANTA MONICA BLVD # 2790 &-#9280	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Info Complete	08/22/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"1st revision to approved set dated 4/4/17 on the plan. Scope includes separation of the electrical system between Petros and Cafe Bougatsa. Cafe Bougatsa's panel used to be fed from Petros' panel, and now, cafe Bougatsa has its own main service meter from the same distribution board as Petros (MS-ELA33). Supplemental permit is required under this scope for new equipments.<<Full PC for New Tenant ""Petros restaurant and Kafe Bougatsa"" Ste. 2790 and 9280.  Install new transformer,  panels and circuits, total effected area: 4,982 sq.ft.>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73697	16041-20000-03285	5400 N BALBOA BLVD #126	91436	5	171B133    15	2259019003	(Q)P-1VLD, QC1-1VLD	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			01/28/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	PIN	34.16914714	-118.50029545	Plan check for power and energy. Project site is an existing commercial building; tenant is a medical office.  Project scope is a tenant improvement. Work is being done within exam rooms. Total lighting area = 542 sq. ft.Note: Building application has been created under	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73698	18041-20000-39770	13574 W FOOTHILL BLVD bldg-2	91342	7	222B157   200	2513006900	RD1.5-1XL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			10/29/2018 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	01/29/2021 12:00:00 AM	ADDRESS	34.30647	-118.42954	New 3-story 27-affordable units apartment.  Scope of this permit is building 2 out of 2 apartment buildings on site.  1600A, 208Y/120V 3ph-4w service (located in Building 1) supplying both buildings 1 and 2 (single feeder).Building permit under 18010-10000-04405.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73699	10041-10000-17244	3900 E CHEVY CHASE DR	90039	13	159B205   748	5593002907	PF-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/31/2010 12:00:00 AM			Corrections Issued	08/31/2010 12:00:00 AM	ADDRESS	34.13327	-118.27281	TI IN AN EXISTING COMMERCIAL BUILDING. PLAN CHECK FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73700	10041-10000-08130	2029 S CENTURY PARK EAST #  1700	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/03/2010 12:00:00 AM	06/08/2010 12:00:00 AM		Permit Finaled	08/13/2010 12:00:00 AM	ADDRESS	34.05956	-118.41375	Ti in an existing office building, on 17th floor. Plan check for T24 and Energy. (Variance was submitted to separate the fire alarm system.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73701	15041-10000-02681	2400 W PICO BLVD	90006	1	129B197  1096	5056002042	[Q]C2-1	South Los Angeles	South Los Angeles	Pico Union		2211.10	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/28/2015 12:00:00 AM	ADDRESS	34.04709	-118.28948	Plan check for Title 24 only. Project is a TI for a self-serve outdoor carwash. Total outdoor lighting area = 13,830 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73702	16041-10000-06007	5126 N DAHLIA DR	90041	14	163-5A227 359	5669012015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	07/09/2016 12:00:00 AM	ADDRESS	34.14037	-118.19959	PV1, rooftop mounted 8.8 kW Ac system using central inverters, (46) modules, (2) 4.2kw  inverters, (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73703	15041-20000-27686	11760 W WELBY WAY	91606	2	180B169   188	2322015031	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.03	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.19291	-118.38976	PV1. Install roof mounted PV system sized 3.8 kW. Interconnected with main service panel.(12) Sunpower E20-327 Modules(1) Powerone PVI-3.8 Inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73704	19041-20000-32296	8416 N FUSION WAY PV1	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	04/03/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF MOUNTED PV SYSTEM ON NEW SFD. SYSTEM SIZE IS 2.8KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH MICRO INVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73705	17041-10000-18726	834 1/2 W 41ST ST	90037	9	114B197   478	5019003025	[Q]R3-1	South Los Angeles	South Los Angeles	Voices of 90037		2317.10	Electrical	Electrical	Apartment			06/05/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.00906	-118.2885	Installation of new roof mounted solar PV system on existing 3 unit apartment building.  Total system size = 3 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73706	15041-10000-05811	12747 W FILMORE ST	91331	7	213B161   576	2527030023	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	02/27/2015 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.27987	-118.41076	PV1 ROOF MOUNTED STANDARD PLAN. TOTAL SYSTEM SIZE 5KWAC. 15 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73707	19041-10000-03370	1335 W 37TH PL	90007	8	117B197    76	5040010020	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2019 12:00:00 AM			Reviewed by Supervisor	02/28/2019 12:00:00 AM	ADDRESS	34.02008	-118.29859	PC FOR PV SYSTEM. 46 HYUNDAI HEAVY INDUSTRIES MODULES WITH 46 IQ7-60-2-US MICROINVERTER. 1 COMBINER BOX . NEW MAIN PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73708	12041-10000-21731	22052 W SAGEBROOK ROAD	91311	12	207B101   555	2723023017	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.11	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2012 12:00:00 AM	10/16/2012 12:00:00 AM		Permit Finaled	01/10/2013 12:00:00 AM	ADDRESS	34.26471	-118.60807	PLAN CHECK FOR NEW INSTALLATION OF ROOF MOUNTED 5.23KW PHOTOVOLTAIC SYSTEM. (SUNPOWER TRANFORMERLESS INVERTER)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73709	19041-10000-12280	624 N EVERGREEN AVE	90033	14	129A227   349	5178011029	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Issued	04/04/2019 12:00:00 AM	ADDRESS	34.04623	-118.19854	PV1(SYSTEM 1) SYSTEM SIZE 6.20KWdc/ 5.25KWac, 21 MODULES CANADIAN SOLAR CS6K-295MS. 21 MICROINVERTERS ENPHASE IQ 7-60-2-US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73710	18041-20000-37295	20720 W BEECH CIR	91326	12	219B109   357	2701098002	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.29282	-118.58503	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73711	15041-20001-18159	20358 W ARMINTA ST	91306	3	189B113   868	2107013040	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.21305	-118.57737	Expedite per applicant request[[[[Plan check for PV roof mounted system. System size: 9.0kW with 30 modules and 2 inverters(3.0kW and 6.0kW) Transformerless]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73712	19041-10000-37191	11355-11377 W OLYMPIC BLVD	90064	11	126B153  1080	4260003008	(T)(Q)C2-2D	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	08/11/2020 12:00:00 AM		Permit Finaled	06/28/2023 12:00:00 AM	ADDRESS	34.03766	-118.44264	MODERNIZATION AND EXPANSION OF 2 EXISTING 10 STORY OFFICE TOWERS WHICH ARE CONNECTED BY AND EXISTING PARKING STRUCTURE. PARKING STRUCTURE  INCLUDE 3 LEVELS ABOVE GRADE AND 2 LEVELS SUBTERRANEAN PARKING. TOTAL AFFECTED AREA IS APPROX 495,000 SQFTBUILDING PERMIT# 19014-10000-05107	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73713	17041-20000-26287	6309 N LANKERSHIM BLVD	91606	2	177B169   119	2335031021	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			08/02/2017 12:00:00 AM	08/02/2017 12:00:00 AM		Permit Finaled	01/24/2018 12:00:00 AM	ADDRESS	34.18511	-118.38706	ti to an existing commercial building.  adding new lighting  new controls to existing panels.  plan check for energy only.  scope of work to be performed in the second floor only of a two story building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73714	19041-10000-04035	1566 W COLORADO BLVD	90041	14	162A227   108	5689018021	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM	02/01/2019 12:00:00 AM		Issued	02/01/2019 12:00:00 AM	ADDRESS	34.13932	-118.20035	Design build: Plan check for a modification in place located in a commercial building. Scope include a total area of 12,000-SQ FT. Portion of permit fee is paid under 18041-10000-16198.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73715	17041-10000-29350	350 S GAFFEY ST	90731	15	018B197  1642	7451019031	[Q]C2-1VL	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	10/15/2018 12:00:00 AM	ADDRESS	33.74094	-118.29211	PC FOR POWER AND ENERGY FOR NEW DRIVE THRU RESTAURANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73716	13041-10001-30883	22443 W HAYNES ST	91307	12	180B101   425	2038033017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	34.18981	-118.61625	Expedited RSES plan check per applicant request. (((PV1, Install 3.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3000A-US. 13 modules Trina Solar TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73717	12041-10000-20863	1330 N VINE ST	90028	13	147A189   195	5546022030	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			09/04/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	01/16/2013 12:00:00 AM	ADDRESS	34.09542	-118.32648	Ti in an existing office. EPC is for T24.  INVESTIGATION FEE INCLUDED.  (( COMPLY WITH DEPARTMENT ORDER effective date 08/30/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73718	19041-10000-35852	22818 W VANOWEN ST	91307	12	180B097    43	2038040028	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	11/19/2019 12:00:00 AM	ADDRESS	34.19344	-118.62437	ENERGY PC FOR TENANT IMPROVEMENT TO (E) RETAURANT. AREA OF SCOPE 555SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73719	18041-10000-05884	4601 E HUNTINGTON DR NORTH	90032	14	142-5A231  38	5213012045	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.0864	-118.18727	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY. TOTAL AFFECTED AREA IS 21870 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73720	19041-10000-16214	8840 N CORBIN AVE	91324	12	195B117    64	2783025092	C1-1L, P-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.23069	-118.56211	FULL PLAN CHECK POWER AND T-24 TO AN EXISTING TARGET STORE. SCOPE INCLUDE ADDING NEW CKTS TO AN EXISING PANELS AND CHANGING LIGHT FIXTURES.  SCOPE OF WORK AREA 87,528SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73721	17041-10000-25403	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.10229	-118.33907	PC FOR POWER AND ENERGY FOR MOVIE THEATER UPGRADE FOR THEATER 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73722	18041-20001-42732	238 S LUCERNE BLVD	90004	4	135B189    73	5515021007	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2018 12:00:00 AM			PC Approved	11/10/2018 12:00:00 AM	ADDRESS	34.0699	-118.32465	expeditepv1install roof mounted pv system sized 9.1KW interconnected with msp, with battery 10KWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73723	10041-10000-22460	808 W 7TH ST	90017	9	129A209    60	5144010022	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	11/19/2010 12:00:00 AM		Permit Finaled	04/22/2011 12:00:00 AM	ADDRESS	34.04883	-118.25927	Ti in an existing Cafe. Plan check for T24 and energy.  REFE.#10042-10000-08207.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73724	19041-10000-00669	2937 E PICO BLVD	90023	14	118-5A221  53	5169008023	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			01/07/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Issued	01/24/2019 12:00:00 AM	ADDRESS	34.01907	-118.21634	TITLE 24 PLAN CHECK FOR - PROPOSED CHANGE OF USE OF A PORTION OF (E) STORAGE SPACE TO FOOD PRODUCT MANUFACTURING; ADD PARTITION WALLS AND KITCHEN HOOD; NEW T- BAR CEILING, AND FLOORING. NEW ACCESSIBLE LIFT. - TOTAL AFFECTED AREA 1000SFPORTION OF THE INSPECTION FEES UNDER DIFFERENT PERMIT 18041-10000-38214	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73725	17041-10000-24102	617 W 7TH ST 1103	90017	14	129A209   113	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.04779	-118.2571	OFFICE TI. PC FOR T24 ENERGY ONLY. CHECKING LIGHTING UPGRADES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73726	13041-20000-04511	17043 W BARNESTON ST PV-1	91344	12	216B133   530	2606018014	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2013 12:00:00 AM	02/21/2013 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	ADDRESS	34.28576	-118.50364	Plan check for PV. Microinverter standard plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73727	10041-10000-05947	20801 W VENTURA BLVD	91364	3	171B109    62	2166033045	(Q)C4-1LD, C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM	06/18/2010 12:00:00 AM		Permit Finaled	10/07/2010 12:00:00 AM	ADDRESS	34.16663	-118.58589	ALTERATIONS FOR A TARGET STORE.  See bold, delta 1, and other clouded items on the plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73728	18041-20001-16944	16644 W ROSCOE PL	91343	12	192B137   310	2689022001	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM			PC Approved	05/31/2018 12:00:00 AM	ADDRESS	34.22118	-118.49573	Clouded revisions to approved set.  Expanded single line diagram showing connection to temporary distribution.  Change from exothermic to mechanical grounding connections.(((Construction of an aviation fuel farm.  Hazardous classification around jet fuel tanks.  Plan check for power.Express permit previously issued under 18041-20000-16969.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73729	17041-10002-37680	5455 W 111TH ST	90045	11	087B173    10	4129036910	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	33.93635	-118.37364	PC FOR CHNAGES TO APPROVED SET . CHNAGES ARE PART OF PHASE 2. SCOPE INCLUDES ADDITION OF SQ.FT AND LIGHT FIXTURES with new panel circuits and equipment. TOTAL NEW ADDED SQ.FT 36000  new total 1146000 sq.ft TOTAL ADDED 5 NEW FIXTURES (7 ADDED 2 REMOVED)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73730	12041-10000-24432	1950 E WASHINGTON BLVD	90058	14	118-5A215  29	5167005015	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM	12/26/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	PIN	34.01879134	-118.23748008	PLAN CHECK POWER AND ENERGY TENANT IMPROVEMENTS TO AN EXISTING BUS MAINTENANCE FACILITY. SITE LOCATE IN METHANE ZONE. EXISTING SERVICE. INSTALLATION OF TRAILERS SEPARATE APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73731	14041-30002-17044	600 WORLD WAY TER # 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	08-10-2017 Changes to an approved set of plan. Changes include refeed elevator(20HP) and 400A MCC to PA switch gear. Changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73732	12041-10000-03136	3555 E WHITTIER BLVD 1-60	90023	14	121-5A227 207	5188005017	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Apartment			02/15/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	11/20/2013 12:00:00 AM	ADDRESS	34.02612	-118.19678	4-story, 60-unit type V-A family apartments over single level of Type-I-A Basement.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73733	16041-10000-28983	1044 W VENICE BLVD	90015	1	126A203    36	5135024035	M1-1	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	08/16/2016 12:00:00 AM	ADDRESS	34.04123	-118.27889	T-24, PC FOR ENERGY ONLY. TI TO AN OUTDOOR BASKETBALL COURT/PLAYGROUND. SCOPE INCLUDES ADDING NEW LIGHTINGS FOR AN EXISTING BASKETBALL COURT AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73734	14041-10001-14426	3033 W WILSHIRE BLVD	90010	10	135B197  1253	5077008017	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			07/27/2016 12:00:00 AM			PC Info Complete	07/27/2016 12:00:00 AM	ADDRESS	34.06198	-118.28733	Changes to approved set of plans. Changes in title 24 and single line minor changes. changes clouded on plans. revised emergency required circuits to dedicated panel. NEW 18-STORY MIXED-USE BUILDING (CORE AND SHELL ONLY) CONSISTING OF 190 APARTMENT UNITS (LEVEL 5-17) ON TOP OF ABOVE GRADE PARKING GARAGE (LEVEL 1-4) AND ROOFTOP SWIMMING POOL AND ASSEMBLY AREA ON LEVEL 18. THE GROUND LEVEL INCLUDES RETAILS (___S.F), LEASING OFFICE (___S.F.) AND RESIDENT AMENITIES (___ S.F.).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73735	11041-20000-21525	2029 S CENTURY PARK EAST Ste 200	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/07/2011 12:00:00 AM			PC Approved	10/07/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I.  Remodel of the light fixtures in Suite 200.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73736	14041-20000-05229	5809 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/02/2014 12:00:00 AM	ADDRESS	33.97382	-118.41992	ROOF-MOUNTED ,PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73737	10041-10001-10823	11000 W VENTURA BLVD	91604	2	162B173   535	2378008001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM			PC Approved	07/18/2011 12:00:00 AM	ADDRESS	34.14028	-118.37038	The plan was reviewed for delta 9 modifications only, which included the relocation of  two Q type luminaires from  the main entry to the alternate entry,, and the addition of  three S type fixtures to the main entry canopy.  See prevously approved plan for require exterior lighting shut orr control.  10041-10000-10823.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73738	18041-20000-40647	16473 W WESTFALL PL	91436	5	162B137   127	2293004004	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.14265	-118.49273	Plan check for PV roof mounted and energy storage system, PV system size: 10.93KW AC CEC 11.88KW DC with 36 PV Modules and 36 Microinverters. Tesla battery Power Wall 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73739	18041-10000-32523	9131 N OAKDALE AVE Suite 130	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	01/24/2019 12:00:00 AM	ADDRESS	34.23697	-118.56716	TI IN AN EXISTING OFFICE AREA IN SUITE# 130. T-24 ENERGY ONLY.BLDG PERMIT: 18016-10000-17189	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73740	15041-20000-38198	13523 W MORRISON ST	91423	4	168B157    38	2359016009	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Refund in Progress	03/15/2017 12:00:00 AM	ADDRESS	34.16046	-118.42776	PV1, roof mounted solar panel, 5.83kW DC system (22)modules #KU2656ZPA, (1)inverter:PVI-5000-OUTD-US-Z-A  Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73741	14041-10000-11245	500 WORLD WAY TERMINAL 5	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	33.94248	-118.40461	permit to be pulled at EPC counter only. Plan check for energy only. T.I. - REMODEL OF (E) RETAIL SPACE INCLUDING PARTITIONS, CEILINGS, FIXTURES, FINISHES, ETC. FOR DUTY FREE SHOP @ LAX.  1275 SQFT.  REVISE STOREFRONT SECURITY GATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73742	19041-10000-18417	930 S HILGARD AVE Level-2	90024	5	135B153   541	4360006029	[Q]R5-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/16/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.06306	-118.44116	Energy plan check for the 2nd floor of a hotel T.I. Scope includes new lighting and equipment with a total lighting area of 6692-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73743	18041-10000-38843	738 N CAHUENGA BLVD	90038	13	141B185   396	5533032029	CM-1VL-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.08455	-118.3286	FIRST TIME TENANT IN A COMMERCIAL SPACE. PLAN CHECK FOR POWER & ENERGY. BLDG PERMIT: 18016-10000-30475	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73744	14041-10000-21991	4152 W CROMWELL AVE	90027	4	153A201    58	5592025020	R1-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2014 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.11513	-118.28279	PV1 9.69KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(2) inverters: {SOLAREDGE SE3800A-US, SOLAREDGE SE3800A-US}]. [(38)modules: {KYOCERA KD255GX-LFB3}] with optimizers: [SOLAREDGE {POWERBOX 300-2NA4AZS}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73745	14041-10000-23855	1331 E 6TH ST	90013	14	126A215   289	5164008005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	04/01/2015 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	PIN	34.03848626	-118.23472481	PC FOR POWER AND ENERGY. CHANGE A PORTION OF EXISTING WAREHOUSE TO RESTAURANT WITH OUTDOOR DINNING. NEW MEZANINE FOR STORAGE USE.TOTAL AREA = 7869 SQ FT (INDOOR)+ UNDIFINED OUTDOOR AREA(TO BE VERIFIED BY APPLICANT). NEW 600 AMP SUB PANEL IS NOT INVOLVED IN THIS PLAN. B # : 14016-10000-12836.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73746	17041-20001-30035	19254 W LANARK ST	91335	3	189B117   160	2104003001	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM			PC Approved	08/29/2017 12:00:00 AM	ADDRESS	34.21733	-118.55313	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD. Line-side tap interconnection.11.4kW ungrounded system. (48) 275W pv modules.Each module has a 320W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73747	10041-10000-05072	200 N VERMONT AVE	90004	13	138B197   493	5501010032	C2-1	Central	Wilshire	Rampart Village	YES	2111.22	Electrical	Electrical	Commercial			03/19/2010 12:00:00 AM			PC Info Complete	03/19/2010 12:00:00 AM	ADDRESS	34.07496	-118.29147	Plan check T-24 Energy (general/emergency) lighting TI Hyundai Auto Showroom.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73748	16041-10000-44010	7649 N VAN NUYS BLVD	91405	6	186B149    61	2210031011	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	34.20976	-118.44913	PC for energy only. Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total SQft = 21615.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73749	10041-10000-16710	1224 S BEVERWIL DR 1-12	90035	5	132A167   219	4330024036	C4-1VL-O	West Los Angeles	West Los Angeles	South Robertson	YES	2691.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	06/17/2011 12:00:00 AM	ADDRESS	34.0554	-118.39891	"TI IN THE AN EXISTING CORIDOR AND ELEVATOR LOBY OF ""MR. C"" HOTEL ON 10 FLOORS (2ND THROUGH 11TH).  PLAN CHECK IS FOR T-24 ENERGY CALCS.  REPLACING EXISTING FIXTURTES 1:1.  EXISTING SWITCHES."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73750	15041-20000-30783	19737 W MALDEN ST	91306	3	192B117   169	2782018022	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Expired	10/13/2017 12:00:00 AM	ADDRESS	34.22553	-118.56361	Plan check for PV1. NEW ROOF-MOUNTED SOLAR SYSTEM. TOTAL SYSTEM SIZE IS 5KW. (26) MODULES-KYOCERA #KU2656ZPA(1) # PVI-5000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73751	11041-10000-06371	11500 W OLYMPIC BLVD	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Public Safety Only			03/31/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	03/05/2012 12:00:00 AM	ADDRESS	34.03624	-118.44415	INSTALL A NEW FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73752	15041-10000-04267	6832 N VALJEAN AVE	91406	6	183B141   698	2224025028	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.19483	-118.4857	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL  AREA5132 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73753	19041-10001-17449	5425 W SANTA MONICA BLVD	90029	13	144B193   701	5536010020	C4-1VL	Central	Hollywood	Hollywood Studio District		1911.20	Electrical	Electrical	Commercial			06/10/2019 12:00:00 AM			PC Approved	06/10/2019 12:00:00 AM	ADDRESS	34.09092	-118.30773	T-24, PC for Energy Only. Scope includes adding Outdoor lights for an outdoor sign. NOTE: Plan Check only. Permit is paid under PCIS#19041-10000-17449	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73754	14041-10000-01743	17530 W SAN FERNANDO MISSION BLVD	91344	12	210B129   362	2712004019	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.27194	-118.51643	PV1. ROOF MOUNTED SOLAR SYSTEM. STANDARD MICROINVERTER PLAN. SYSTEM SIZE: 4.32 KW DC(20) SOLARWORLD PLUS SW270 MONO(20) ENPHASE M215 MICROINVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73755	19041-20000-53858	10725 W ASHTON AVE	90024	5	132B153   269	4325001017	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			12/31/2019 12:00:00 AM	07/23/2020 12:00:00 AM		Issued	07/23/2020 12:00:00 AM	ADDRESS	34.05969	-118.43638	800A 240/120V 3ph-4w service, distribution boards, power and lighting for new construction.  Plan check for power and energy.  building permit 17010-20000-03515	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73756	17041-10001-28729	11950 W FOOTHILL BLVD	91342	7	210B165    41	2532012039	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.2757	-118.3967	Supplemental to changes to approved set of plans - Changes include addition of new general use receptacles to approved set of plans in cardio area - changes reflected under delta 8 onlyPlan check power and energy for Interior TI (planet fitness) - change of use from retail/grocery to fitness center/gym. Scope includes new panels circuits, equipment and lights (incl. emergency)Total affected area indoor 19,779sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73757	18041-10001-03182	2010 E WASHINGTON BLVD	90021	14	118-5A215  44	5167005805	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			08/29/2018 12:00:00 AM			Reviewed by Supervisor	09/04/2018 12:00:00 AM	PIN	34.01855522	-118.23487686	PLAN FOR CHANGES TO APPROVED SET OF PLANS AS DELTA 1. CHANGES INCLUDE RELOCATION OF EXISTING LOADS, REMOVAL OF ELECTRICAL EQUIPMENT FOR SINGLE LINE DIAGRAM, AND REVISIONS TO OUTDOOR LIGHTING PLAN AS WELL AS TITLE 24 MODIFICATIONS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73758	15041-10001-07138	156 S MARTEL AVE	90036	5	138B181  1127	5512015023	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	07/13/2015 12:00:00 AM	ADDRESS	34.07193	-118.35094	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73759	15041-10000-03240	2035 E VIOLET ST	90021	14	124-5A217 370	5166014003	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM			PC Approved	02/11/2015 12:00:00 AM	ADDRESS	34.0327	-118.23098	void ( LOST SET OF PLANS. )Change of use from warehouse to office, TI for corridor, restrooms, a utility room and a office in the core shell area only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73760	19041-10000-51515	8949 N ONEIDA AVE	91352	6	195B165   268	2631006034	RS-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	05/20/2020 12:00:00 AM	ADDRESS	34.23214	-118.39682	NEW PV1 INSTALLATION 5.27KWdc (5.0KWac) USING 17 CS6K-310MS DC MODULES, 17 SE P320 POWWR OPTIMIZERS & 1 SE 5000H-US CENTRAL INVERTER.CONNCETED TO A NEW 200 AMP SERVICE. NEW SERVICE UNDER SEPARATE PERMIT.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73761	15041-20000-11922	5698 S GOLDENEYE CT Unit 1	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	08/15/2016 12:00:00 AM	ADDRESS	33.9792	-118.41068	Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL APPLY TO UNIT # 2 AND #3 OF ADDRESS 5698 GOLDENEYE CORT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73762	12041-10000-02524	800 W WORLD WAY Term 8-Spc 8G	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	03/14/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	T.I. to an existing retail area, in LAX, Terminal 8, Space 8G.  Change to lighting, new circuits, receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73763	13041-20002-29527	6611 N VALJEAN AVE	91406	6	180B137   263	2233031044	M1-1, P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	ADDRESS	34.19064	-118.48601	"((ADDING LADWP PERFORMANCE METER))PV2 COMMERCIAL INSTALLATION. TOTAL SYSTEM SIZE 33KW. 132 MODULES AND 3 INVERTERS. ""$0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73764	19041-20000-39020	707 W WILSHIRE BLVD Ste 4300	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM	09/27/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.04893	-118.2572	Power and lighting for commercial office TI.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73765	13041-10000-30634	550 S HILL ST	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	11/01/2013 12:00:00 AM		Permit Finaled	11/19/2013 12:00:00 AM	ADDRESS	34.04753	-118.25268	T-I , T24 only, office space in jeweler mart.  suite 1490	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73766	15041-10001-30820	1803 W 29TH ST	90018	8	123B193  1166	5053026026	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM			PC Approved	09/29/2015 12:00:00 AM	ADDRESS	34.02924	-118.30336	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<<INSTALL 5.565 KW DC ROOF-MOUNTED ROOF-MOUNTED ON  A SINGLE FAMILY HOUSE.(21) MODULES: KYOCERA KU2656ZPA(1) INVERTER: ABB PVI-4.2-OUTD-S-US-Z-A>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73767	18041-20001-44473	3560 S WATT WAY	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM			PC Approved	06/06/2019 12:00:00 AM	ADDRESS	34.02169	-118.28671	06-06-2019 Changes to an approved set of plan, changes include replace lighting in with different fixture due to change of use in the space. Changes has been clouded as delta 2. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73768	11041-10000-08327	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			04/26/2011 12:00:00 AM	06/30/2011 12:00:00 AM		Permit Finaled	12/13/2011 12:00:00 AM	ADDRESS	34.04842	-118.33486	INSTALL NEW FIRE ALARM SYSTEM IN BRAND NEW RETAIL MALL WITH PARKING GARAGE.  353 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73769	13041-10005-35881	431 W 7TH ST 5th floor-6th floor	90014	14	129A209   169	5144003036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.04654	-118.25516	03/26/19Changes to an approved set of plans. All changes are clouded under Delta 38. Changes includes adding new return duct detectors for 7 fan coil units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73770	16041-10001-27638	7050 N TOPANGA CANYON BLVD	91303	3	183B101   258	2138002038	(Q)C2-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			03/01/2017 12:00:00 AM			PC Approved	03/01/2017 12:00:00 AM	ADDRESS	34.19875	-118.60563	CHANGES TO APPROVED SET OF PLANS. CHECKING FOR NEW FLOOR LAYOUT. ALL CIRCUIT WIRING REMAINS AND MINOR LIGHITNG UPDATE. CHANGES NOTED DELTA 1 ON PLANS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73771	10041-10000-09507	3911 S FIGUEROA ST	90037	8	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area, Voices of 90037		2312.20	Electrical	Electrical	Commercial			05/20/2010 12:00:00 AM	07/07/2010 12:00:00 AM		Permit Finaled	08/05/2010 12:00:00 AM	ADDRESS	34.01366	-118.28294	"34'X36'-6"" ""L SHAPED"" ADDITION TO EXISTING CONCESSION STAND OUTSIDE THE LA COLISEUMPLAN CHK IS FOR TITLE 24"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73772	18041-10002-07287	2139 S CAMDEN AVE	90025	5	126B153   609	4322018013	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Issued	03/06/2018 12:00:00 AM	ADDRESS	34.04151	-118.4366	PC FOR NEW ESS  (PV UNDER MASTER)SCOPE INCUDES SINGLE POWERWALL 2 WITH NEW SUBPANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73773	14041-10000-28890	5450 W PICO BLVD	90019	10	129B177   985	5069029022	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM			PC Info Complete	05/11/2015 12:00:00 AM	ADDRESS	34.04862	-118.35714	Plan check for power. Upgrading service from 800 amps to 1200 amps.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73774	19041-20000-15373	8147 W MULHOLLAND TER	90046	2	156B173   317	2381029002	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	06/13/2019 12:00:00 AM	ADDRESS	34.12389	-118.37762	PV1.  Install 14.04 kW roof mounted grid tied PV system.  (39) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73775	18041-10000-39297	380 WORLD WAY BURBERRY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Finaled	12/02/2020 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLAN CHECK FOR T24 ONLY, TENANT IMPROVEMENT FOR EXISTING STORE IN LEVEL 4 , SPACE T-18 (BURBERRY). TOTAL AREA: 942 SQ.FT(B#  18016-10000-28744)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73776	19041-20000-13887	3030 1/2 N COOLIDGE AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/18/2019 12:00:00 AM		Permit Finaled	11/24/2020 12:00:00 AM				Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73777	18041-10000-43609	3501 W SUNSET BLVD	90026	13	144A203   188	5429024001	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM			PC Info Complete	11/14/2018 12:00:00 AM	ADDRESS	34.08906	-118.27633	Service upgrade to 600 Amp in a single story commercial building with multi tenants. There are NO connected load to the service. Future TI's will require plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73778	19041-10001-17246	19161 S HARBORGATE WAY	90501	15	060B193   442	7351021044	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	33.85627	-118.30374	CHANGES ON APPROVED SET OF PLANS TO REFLECT FIELD CONDITIONS. CHANGES INCLUDE EMERGENCY LIGHTING AND NOTE TO SINGLE LINE DIAGRAM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73779	13041-10001-36165	5550 W HOLLYWOOD BLVD	90028	13	148-5A193 187	5544025019	[Q]R5-2	Central	Hollywood	Hollywood Studio District		1905.10	Electrical	Electrical	Apartment			08/13/2015 12:00:00 AM			Corrections Issued	09/14/2015 12:00:00 AM	ADDRESS	34.10155	-118.31097	Change to approved set under field request. all changes are under pre-clouded area and within the description of the narative letter only;     (((((((((((((((((     2-13-15  m.zandi  addition of 50 branch circuits for basement circuitry  and title 24  percustomers information.))))))))))))))))))))))  New mixed-use 8-story, 280 unit apartment/retail over parking garage:NOTE: APPLICANT BROUGHT A CHECK FOR THE FEES PRPARED BY ARCHITECT;FEES FOR FIRE PLANS VARIANCE AND ENERGY PLAN CHECKS ARE PENDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73780	16041-20001-18456	420 E MONTECITO DR	90031	1	147A225   179	5303005033	[Q]R1-1D-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1993.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM			PC Approved	05/31/2016 12:00:00 AM	ADDRESS	34.09504	-118.20137	Expedite per applicant request{{{{Plan check for PV roof mounted system. System size: 3.8kW with 8 modules and 1 inverter(3.8kW)}}}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73781	19041-10001-27685	353 S BROADWAY 400	90013	14	130-5A211 152	5149015022	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Approved	08/22/2019 12:00:00 AM	ADDRESS	34.04991	-118.24934	08-22-2019 Changes to an approved set of plan. Changes include revise emergency lights and remove notes for control receptacle and duplex, data outlet. All Changes has been clouded as delta 1 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73782	19041-10000-34101	8901 N RESEDA BLVD	91324	12	195B125   418	2770005012	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	34.23214	-118.53628	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 (OUTDOOR ONLY)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73783	16041-20000-11669	700 S FLOWER ST #600	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is the 6th floor of an existing commercial, high-rise building. Project scope is a tenant improvement. Total lighting area = 7,001 sq. ft.Note: Building permit has been pulled under 16016-30000-03496	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73784	17041-10001-18423	17412 W CHASE ST	91325	12	192B129   220	2787018003	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.22318	-118.51281	Supp for expdite fee.PC FOR ROOF MOUNTED PV SYSTEM CENTRAL INVERTER (2) W/ OPTIMIZERS.SYSTEM SIZE 13.6KWAC (SE6000 AND SE7600)47 MODULES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73785	17041-10000-40585	13479 W OSBORNE ST	91331	6	198B157   189	2621022014	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	Commercial			11/09/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.24155	-118.42709	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73786	17041-10001-03691	3774 S WESTERN AVE	90018	8	117B193   610	5036008035	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM			Reviewed by Supervisor	11/21/2017 12:00:00 AM	ADDRESS	34.01805	-118.30873	SUPPLEMENTAL FOR LOST SET OF PLAN - FULL PLAN CHECK CONVERT EXIST GAS STATION TO NEW FOODMARKET, SINGLE STORY BUILDING. NEW SERVICE RATED AT 600 FOR 120/208 V 3PH 4W. ALL NEW EQUIPMENT AS SHOWN ON SINGLE LINE. AREA IS 2219 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73787	16041-20000-03255	1706 S PREUSS ROAD	90035	5	129B169   979	4303004028	R1-1	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	1 or 2 Family Dwelling			01/28/2016 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	07/13/2016 12:00:00 AM	ADDRESS	34.04837	-118.3845	Paln check for PV roof mounted system. System size: 3.8kW with 19 modules and 1 inverter(3.8kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73788	16041-30000-35114	801 S FIGUEROA ST 7TH FLR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM			PC Approved	10/04/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	Title 24 plan check.  Remodel existing restroom on the 7th floor in existing office building.  New lighting and receptacles.  Total area = 640 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73789	11041-10000-14332	3701 W SANTA ROSALIA DR	90008	8	114B185   631	5032002042	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Finaled	10/13/2011 12:00:00 AM	ADDRESS	34.00755	-118.33781	NEW FIRE ALARM SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73790	18041-10000-03873	430 S ANDERSON ST	90033	14	127-5A219 373	5171008002	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM	02/06/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	34.04131	-118.22487	Energy plan check for an existing warehouse with new added offices. Scope includes new lighting and equipment. Total area is 10,466 SQ FT.bld #: 17016-10000-10581	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73791	11041-20000-12644	16830 W KINGSBURY ST	91344	12	207B133   675	2684018036	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Apartment			06/17/2011 12:00:00 AM	10/18/2011 12:00:00 AM		Permit Finaled	12/09/2011 12:00:00 AM	ADDRESS	34.26299	-118.4993	Plan check new roof mounted 155KW Photovoltaic system on apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73792	11041-10000-05283	16530 W VENTURA BLVD	91436	5	168B137   374	2284005026	C4-1L, RE9-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	Commercial			03/17/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	08/24/2011 12:00:00 AM	ADDRESS	34.15753	-118.49341	CHANGE OF USE OF FIRST FLOOR TENANT SPACE [3364 S.F.] FROM OFFICE TO MEDICAL OFFICE.  TENANT IMPROVEMENT.  TWO NEW 100 AMP PANELS, X-RAY MACHINE, AND NEW 30 & 50 KVA TRANSFORMERS.  T-24 PLUS FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73793	15041-20000-16834	2600 S VERMONT AVE	90007	8	153B197    23	5588030013	RE11-1, [Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area	YES	2218.10	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	06/02/2015 12:00:00 AM		Permit Finaled	07/06/2015 12:00:00 AM	ADDRESS	34.03252	-118.29135	Plan check for Ralphs Title 24 only in restrooms area. Total area: 174 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73794	11041-20000-11676	1423 N ORIOLE DR Guest-House	90069	4	147B169   711	5560006015	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2011 12:00:00 AM			Corrections Issued	06/14/2011 12:00:00 AM	ADDRESS	34.09755	-118.38834	Plan check for guest house being supplied from main house application #11041-20000-11675.  (Plan check 2 of 2)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73795	15041-20000-22787	9121 N OAKDALE AVE #120	91311	12	198B113   151	2761001085	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.23622	-118.56725	Plan check for Title 24 only T.I. in existing office. Total indoor area: 2,064sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73796	19041-20001-25127	10074 W SULLY DR pv1	91352	2	189B181    75	2403019012	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.218	-118.34978	expeditepv1install roof  mounted pv system sized 11.4KW AC with (1) ESS interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73797	15041-10000-38581	2475 W LINDSAY LANE	90039	4	148-5A207  48	5439017005	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	12/15/2015 12:00:00 AM	ADDRESS	34.10268	-118.26153	PV1, SOLAR ROOF MOUNTED SYSTEM USING OPTIMIZERS. TOTAL SIZE. 8350. (30) MODULES AND (1) INVERTER. (30) SUNVIA OPTIMUS 280 MONO(1) SOLAR EDGE SE7600 US.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73798	18041-20000-47081	210 E LINNIE CL	90291	11	106-5A145 604	4227009028	RW1-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM			PC Approved	03/13/2020 12:00:00 AM	ADDRESS	33.98391	-118.46737	Plan check for power only. Project site is a new 3-story single-family dwelling. Work includes a 600 amp service.Note: Building application has been generated under 18010-10000-04050	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73799	18041-10000-17838	7225 N WOODMAN AVE	91405	2	183B157    14	2216034048	C1-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.20182	-118.43147	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73800	14041-10001-10035	2448 W RIVERSIDE DR	90039	13	150A209   182	5438005017	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2014 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	05/23/2014 12:00:00 AM	ADDRESS	34.10515	-118.25563	Changes to approved set: adding 1 module for a total of 8 modules CS6P-250PX on transformerless system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73801	14041-20000-13387	10920 N NASSAU AVE	91040	7	208-5A193  61	2551029007	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2014 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Expired	06/14/2016 12:00:00 AM	ADDRESS	34.26764	-118.31036	PV1 ROOF MOUNTED PV SYSTEM SIZED 4.5KW INTERCONNECT WITH MAIN PANEL UPGRADED TO 200A.(18) SUNPOWER MODULES SPR-X20-250(1) SOLAR EDGE TRANSFORMERLESS INVERTER 3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73802	11041-10000-03637	444 S FLOWER ST 7Th & 8Th-Floors	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			02/25/2011 12:00:00 AM	03/30/2011 12:00:00 AM		Permit Finaled	09/14/2011 12:00:00 AM	ADDRESS	34.05189	-118.25546	TI IN AN HIGH RISE OFFICE BUILDING ON THE 7TH & 8TH FLOORS. PLAN CHECK IS FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73803	16041-10000-23492	900 W WILSHIRE BLVD 7th Floor	90017	14	130-5A209 237	5144008024	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/20/2016 12:00:00 AM	01/23/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.05001	-118.25963	FULL PC FOR POWER AND ENERGY. FIRST TIME TENANT. TI FOR LEVEL 7 IN A HIGH RISE COMMERCIAL BUILDING (WILSHIRE GRAND). FITNESS CENTER. SCOPE INCLUDES ONE NEW 400A SUBPANEL, NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 11466 SQ FT. B#16016-10000-15646	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73804	13041-10000-27131	10921 N OSO AVE	91311	12	210B113   147	2707032010	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	11/06/2013 12:00:00 AM	ADDRESS	34.26868	-118.57695	Cashier: Fees have reached the limit set by State Assembly bill for permitting PV systems installation. fee shown as zero is correctPV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 225A MAIN; WORK DONE ON A NON-STANDARD PLAN. 5 TOTAL STRINGS; COMBINER BOX WILL BE USED, ALONG WITH A 125 LOAD CENTER; DC NEGATIVELY GRNDED, SYSTEM SIZE IS 16.75KW DC WITH (67) MODULES: TRINA #TSM-250PA05.18(2)FRONIUS #IG PLUS V 7.5(1)SHOALS# STG-CBRH-3-A COMBINER BOX; 3 STRING, 90A, 600V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73805	15041-10000-40952	314-326 S LINCOLN BLVD	90291	11	111B145   634	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			12/04/2015 12:00:00 AM			Corrections Issued	12/04/2015 12:00:00 AM	ADDRESS	34.00118	-118.46712	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 3278.SHELL AND CORE RENOVATIONS BY BUILDING OWNER. SCOPE INCLUDES EXTERIOR FACADE RENOVATIONS ON 2 SIDES, NEW GLAZING AND STOREFRONT, RE-ROOF, INTERIOR CIRCULATION RECONFIGURATIONM AND FINISHES 42,000 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73806	13041-20000-32929	1872 S SEPULVEDA BLVD 1-3	90025	5	126B153    95	4323021015	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM			PC Approved	11/25/2013 12:00:00 AM	ADDRESS	34.04498	-118.44183	T24 FOR EXISTING DENTAL OFFICE. SCOPE OF WORK ONLY COVERS RETROFITTING LIGHT FIXTURES ONE FOR ONE. RECONNECTING TO EXISTING CIRCUITS AND EXISTING SWITCHING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73807	16041-10000-01903	2000 W 3RD ST	90057	1	135A205   295	5154028028	C2-1	Central	Westlake	Westlake North		2089.03	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM	08/01/2016 12:00:00 AM		Permit Finaled	07/09/2018 12:00:00 AM	ADDRESS	34.06229	-118.27182	Full PC. New 3 story apartment building plus subterranean garage/retail. New 1600 A service, 33 typical units. Total sq ft = 16283*4/14/16: conduit only filed	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73808	15041-20000-32029	4300 N RHODES AVE	91604	2	165B165   658	2367002012	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	12/02/2015 12:00:00 AM	ADDRESS	34.14874	-118.40289	PV1 SFD. TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM. TOTAL OF 46 MODULES. SYSTEM USES POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73809	13041-20001-31673	20133 W SHERMAN WAY	91306	3	183B113    24	2114019009	C4-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.20128	-118.57238	Modification to approved set of plans.  Change to service size, sub feeder sizes, new circuits and re-locating loads on panels.<<<T.I. to an existing retail space, new 1600 amp switch board.  Change to lighting, Tailored Method. DD's discount>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73810	18041-30000-19810	5700 N CANOGA AVE 1ST FLR	91367	3	174B105    83	2149019015	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			05/29/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.17365	-118.59715	Plan check for T24 only, TI on (E) 1st floor commercial space. Install 225 A panelboard, new circuitry, new additional load < 200A. Area under the scope: 4771 sq.ft(B# 18016-10000-13771)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73811	14041-20000-07208	20212 W VALERIO ST	91306	3	186B113   670	2114012121	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.20	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	ADDRESS	34.20423	-118.57356	Roof mounted PV system with 7.5KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73812	16041-10000-13783	6915 N VAN NUYS BLVD	91405	6	183B149   525	2219026042	C2-1L, R3-2	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.19621	-118.44905	PC for energy only. Remove HID fixtures and replace with new LED fixtures. Total sqft = 7520	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73813	19041-20000-41445	9043 W BURROUGHS ROAD	90046	4	153B169   514	5564024028	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	10/25/2019 12:00:00 AM	ADDRESS	34.11452	-118.39167	PV1 PLAN CHECK FOR NEW ROOF PV FOR EXISTING SFD. SYSTEM SIZE IS 12 KW DC/10.492 KW AC. SCOPE OF WORK CONSISTS OF (40) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73814	16041-20000-07293	1558 N GORDON ST	90028	13	148-5A191 287	5545009011	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	03/13/2018 12:00:00 AM	ADDRESS	34.09976	-118.31949	Plan check for a fire alarm system for an apartment building. Fire alarm system consists of (1) FACP, (1) annunicator, and (128) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73815	12041-20000-17463	21240 W BURBANK BLVD	91367	3	174B105    40	2149016026	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	10/22/2012 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	34.17307	-118.59314	Plan check for replacing two 1000KW generators with two new 750KW generators. Two generators run parallel at the same time. Circuits for generators preinstalled from manufacturer. Building 37	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73816	14041-20001-24875	7014 S HOOVER ST	90044	8	102B201   676	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97563	-118.28691	EXPEDITE PER CUSTIOMER REQUEST.INSTALL ROOF MOUNTED PV SYSTEM SIZED 2.0KW INTERCONNECTED WITH HOUSE PANEL.ENPHASE M250 MICROINVERTER.ZONING CLEARANCE UNDER THIS APPLICATION SHALL BE APPLICABLE FOR ALL SOLAR INSTALLATIONS UNDER THIS BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73817	13041-10000-22681	6700 W SANTA MONICA BLVD FLOOR 1-FLOOR 2	90038	4	144B185   780	5532026023	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Approved	12/06/2013 12:00:00 AM	ADDRESS	34.09055	-118.33652	TITLE-24 PLAN CHECK FOR LOBBY AND RESTROOM REMODELING ON TWO FLOORS. EMERGENCY LIGHTING IS ON THE FIRST FLOOR. ELECTRICAL PERMITTO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73818	13041-10000-09132	3501 S WATT WAY	90089	8	120A201    44	5039012030	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/09/2013 12:00:00 AM	06/06/2013 12:00:00 AM		Permit Finaled	12/19/2013 12:00:00 AM	ADDRESS	34.02243	-118.28658	PLAN CHECK FOR NEW FIRE ALARM SYSTEM  AT USC HERITAGE HALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73819	19041-20000-06094	21345 W DEERING CT	91304	3	189B105   117	2109001020	M2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	10/28/2019 12:00:00 AM		Permit Finaled	10/28/2020 12:00:00 AM	ADDRESS	34.21659	-118.59627	Power and lighting for change of use from auto repair to hydroponic agricultural enterprise. (E) 400A 480Y/277V 3ph-4w service.  Note: Building permit has been issued under 18014-30000-00854	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73820	19041-10000-53818	13200 S ESTRELLA AVE	90248	15	081B201   340	6132003033	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.20	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	33.91286	-118.28606	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73821	19041-10001-02280	1925 S CENTURY PARK EAST SUITE 1300	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/08/2019 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.06066	-118.41426	pc for change of approved set. original set was T-24 only. change marked delta 3. remove of transformer adding 4 ckts for pwr.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73822	19041-10000-02072	506 S STANFORD AVE	90013	14	127-5A213 451	5147018031	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.04221	-118.24131	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73823	13041-10000-25234	4105 S MOORE ST	90066	11	108B153   344	4230028028	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	33.99398	-118.43576	[][] BOLLARDS TO BE INSTALLED FOR THE PROTECTION OF ELECTRICAL EQUIPMENTS SUBJECTED TO VEHICULAR TRAFFIC DAMAGE][][][PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE 5.635KW DC, IN A SINGLE-STORY HOME. INVERTER IS XFORMERLESS, UNGROUNDED WITH OPTIMIZERS.  (23)MODULES: TRINA TSM-245, (1) SOLAREDGE #SE5000A-US, (23)SOLAREDGE OP250-LV	Y	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73824	14041-20001-04389	18833 W RAYEN ST	91324	12	195B121   229	2770001016	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2014 12:00:00 AM			PC Approved	02/25/2014 12:00:00 AM	ADDRESS	34.23197	-118.5437	EXPEDITE FEES))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73825	18041-20000-39300	1825 N LAS PALMAS AVE	90028	13	150A185   276	5547001025	[Q]R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			10/15/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	10/21/2020 12:00:00 AM	ADDRESS	34.10476	-118.33652	Plan check for a fire alarm system for a 6-story, 118 unit apartment building. Fire alarm consists of (1) FACP, (1) annunciator, and (472) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73826	12041-20000-11431	10924 S MAIN ST	90061	15	088-5A205 163	6073008032	C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	Commercial			05/17/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	33.9367	-118.2737	T.I. to office space (Suite A).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73827	12041-10000-07900	10326 N SAMOA AVE	91042	2	204B201   371	2565007036	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2012 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	05/02/2012 12:00:00 AM	ADDRESS	34.25677	-118.28683	New 6.468kw rooftop, photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73828	17041-20001-45568	18800 W COVELLO ST	91335	3	186B121   300	2118004021	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.20737	-118.54276	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system w/roof-mounted array for SFD.10.4kW ungrounded system. (2) 5.2kW inverters.(29) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73829	18041-10001-22138	7422 W 80TH ST	90045	11	099B157   286	4114014017	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2018 12:00:00 AM			PC Approved	07/26/2018 12:00:00 AM	ADDRESS	33.96364	-118.42711	INSTALL A 11.375 (DC) KW, 10.46 (AC) KW, WITH 35 SOLAR MODULES ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73830	16041-10000-05840	1730 W PACIFIC COAST HWY	90717	15	033B193   902	7553018084	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		6701.00	Electrical	Electrical	Commercial			02/18/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	33.78931	-118.30863	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW 600A 120/208V 3 PHASE 4 WIRE SERVICE. NEW STARBUCKS STORE. TOTAL AFFECTED AREA IS 11,441 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73831	15041-10000-03101	10471 N HADDON AVE	91331	7	207B157  1165	2646007002	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	05/05/2015 12:00:00 AM	ADDRESS	34.26045	-118.4283	PV1, 3KW AC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE,(11)  MODULES SUNPOWER SPR-327NE-WHT-D (1) INVERTER ABB PV1-3.0-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73832	18041-10000-05235	2025 S AVENUE OF THE STARS S. TOWER	90067	5	132B161   713	4319004109	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	09/19/2022 12:00:00 AM	ADDRESS	34.05715	-118.41482	PC FOR POWER AND ENERGY TO PHASE 4B ( SOUTH TOWER) 45 STORY MIXED USE CONDO TOWER WITH 130 CONDO & 5 HOUSE KEEPING UNITS. SERVICE EQUIPMENT WILL BE SUBMITTED ON GARAGE LEVEL APPLICATION. TOTAL SQ. FT. 127,028.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73833	19041-10000-51335	1355 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   194	5037001024	C2-1L-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.10	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Approved	12/24/2019 12:00:00 AM	ADDRESS	34.01106	-118.29969	TI IN AN EXISTING COMMERCIAL AREA. INSTALLING NEW LIGHTS. T-24 ENERGY ONLY.Electrical Permit: 19041-10000-49117	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73834	16041-10000-28958	1649 W SEPULVEDA BLVD	90501	15	045B193   440	7347017025	[Q]M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/15/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	33.8169	-118.30807	"REPAIR FIRE DAMAGE PORTIONS OF BUILDING. NEW LIGHTING. PC FOR T24 ENERGY ONLY.""COMPLY WITH DEPARTMENT ORDER effective date 03/15/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73835	19041-10000-44492	17444 W MAYFLOWER DR	91344	12	213B129   116	2607009001	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	11/05/2019 12:00:00 AM		Permit Finaled	01/07/2020 12:00:00 AM	ADDRESS	34.28212	-118.51435	[EPLAN] NEW PV1 ROOFTPOP INSTALLATION WITH A SYSTEM SIZE OF 8.375 kW DC/ 7.6 kW AC WITH A SOLAREDGE CENTRAL INVERTER (SE7600H-US), 25 MODULES (LG335N1C), AND 25 SOLAREDGE OPTIMIZERS (P320).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73836	18041-20000-21145	700 S FLOWER ST #650	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/07/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 Energy only in existing space T.I. Total area: 6523 sq ft. B#18016-10000-17027	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73837	13041-10001-31978	685 E MILFORD ST	90042	14	150A233    24	5312023039	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1837.02	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2013 12:00:00 AM			PC Approved	02/10/2014 12:00:00 AM	ADDRESS	34.10669	-118.17979	][][]EXPEDITED PER APPLICANT REQUEST ][][][]PV1 , ROOF-MOUNTED SOLAR ARRAY INSTALLATION INTERCONNECTING TO EXISTING 200A MAIN. SYSTEM IS A MIXTURE OF MICROINVERTERS WITH A CENTRAL INVERTER, TO BE COMBINED @ 60A LOAD CENTER. WITH (11) SOLARWORLD 270W MODULES TO BE CONNECTED VIA 2500W BLUEPLANET CENTRAL INVERTER, (5) ENPHASE M215 MICROINVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73838	17041-20001-41504	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	12/08/2017 12:00:00 AM	ADDRESS	34.28583	-118.51165	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 14.145 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73839	17041-10000-08282	221 S FIGUEROA ST 120	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	04/28/2017 12:00:00 AM	ADDRESS	34.05628	-118.25373	tenant improvement work to include new non-structural walls, ceiling, power / data, millwork & finishes (1st floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73840	18041-20001-28957	5427 MARMION WAY	90042	1	151-5A227 229	5468022017	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	PIN	34.10922421	-118.19694644	08-22-2018 Changes to an permitted set of plan, Changes include addition of 1 PV module to 8 PV modules, total PV modules: 9, new System size: 2.88kW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73841	19041-20000-22271	1900 S FIGUEROA ST	90007	9	124-5A205 279	5126008011	M1-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/22/2020 12:00:00 AM	ADDRESS	34.03412	-118.27196	PLAN CHECK FOR T24 TI REMODEL OF A EXISTING CAR DEALERSHIP. LIGHTS AND OUTLETS ONLY. TOTAL SQUARE FOOTAGE = 6241SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73842	14041-10000-11089	938 E 60TH ST	90001	9	105B209    84	6007007006	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	04/28/2014 12:00:00 AM		Permit Finaled	05/09/2014 12:00:00 AM	ADDRESS	33.98557	-118.25878	Remove HID light fixtures and replace with new fluorescent fixtures. TOTAL AREA 5845 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73843	17041-10003-03721	13720 W VANOWEN ST	91405	2	180B157    55	2238010030	C2-1, R1-1, [Q]C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	Commercial			10/18/2017 12:00:00 AM			PC Approved	10/18/2017 12:00:00 AM	ADDRESS	34.19378	-118.43188	Changes to approved set noted under delta 1: revise single line diagram.This is plan check only, permit is covered under master# 17041-20000-03721<<Plan check for power only. Project site is a new car wash. Project scope is a new service of 600-amps and new distribution equipment.Note: Building permit has been pulled under 15010-30000-00895>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73844	16041-20000-18349	15509 W DEVONSHIRE ST	91345	7	204B145   291	2649015045	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.25747	-118.47002	PLANCHECK FOR T24 ENERGY.  Tenant improvement to the existing retail store (1,376 sf). AT&T DEALERSHIP.  1334 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73845	18041-10000-48422	101 S THE GROVE DR J1A/J1B	90036	4	138B177  1131	5512003045	(T)C2-2D-O, C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM			PC Info Complete	12/20/2018 12:00:00 AM	ADDRESS	34.07256	-118.35874	T-24 ENERGY PC PER APPLICANT REQUEST. SCOPE OF WORK IS ADDING 1 NEW LIGHT FOR MINIMAL LIGHTING FOR INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73846	17041-20000-35673	122 S ST ANDREWS PL	90004	4	138B193  1132	5516025029	R3-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.07248	-118.31118	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 22.44 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73847	18041-10001-01587	767 S ALAMEDA ST STE 600	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	DELTA 1, 2 & 3 CHANGES TO THE APPROVED PLANS.<<<FULL PC FOR POWER AND ENERGY ONLY. SCOPE INCLUDES NEW 400A 3PHASE 4 WIRE DISTRIBUTION BOARD, NEW PANELS AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 30863 SQ. FT.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73848	14041-20000-02671	1031 W WEST 34TH ST	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.02488	-118.28874	T24 FOR CONTROLS ONLY FOR PARKING LOT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73849	14041-20000-22947	20318 W RUSTON ROAD	91364	3	165B113    34	2174022006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	10/03/2014 12:00:00 AM	ADDRESS	34.15203	-118.57711	PV1.  Install 6.375 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73850	10041-20000-04971	6933 W HOLLYWOOD BLVD unit c	90028	13	147B181   135	5548004003	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			03/18/2010 12:00:00 AM	05/07/2010 12:00:00 AM		Permit Finaled	05/26/2010 12:00:00 AM	ADDRESS	34.10171	-118.34135	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73851	15041-10006-35073	700 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM			PC Approved	05/02/2017 12:00:00 AM	ADDRESS	33.94286	-118.39982	05/02/2017 Changes to an approved set of plans under delta 40.  Changes include removal of circuits and addition of  2 luminaires. Update to title 24 forms.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73852	11041-20000-15908	2200 W 3RD ST	90057	1	135A203   309	5154034006	C2-1	Central	Westlake			2088.00	Electrical	Electrical	Commercial			07/29/2011 12:00:00 AM	07/29/2011 12:00:00 AM		Permit Closed	10/03/2011 12:00:00 AM	ADDRESS	34.0632	-118.27405	addition to fire alarm	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73853	18041-20003-36457	11419 N MONTALCINO WAY	91326	12	213B109   412	2701068023	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2019 12:00:00 AM			PC Approved	06/18/2019 12:00:00 AM	ADDRESS	34.27907	-118.58671	SUPPLEMENTAL PLAN CHECK ONLY, FOR CHANGES TO APPROVED SET. CHANGES TO SINGLE LINE DIAGRAM. REMOVAL OF A 200A BREAKER AND AN ADDITION OF TWO NOTES REGARDING THE FUSED HEAVY DUTY SERVICE DISCONNECT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73854	14041-20000-12371	11073 W PICO BLVD	90064	5	126B153  1147	4322021029	M2-1VL	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.03738	-118.43479	PLAN CHECK FOR ENERGY ONLYSingle unit (dessert shop) of a one story commercial building, part of a strip mall. Replacement of existing lights. Installation of auto-shutoff controls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73855	11041-10000-16860	23201 W SYLVAN ST	91367	3	177B093   116	2035020049	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			08/10/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.18473	-118.63167	Residential PV System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73856	15041-10000-32098	201 S OLIVE ST	90012	14	132A211    59	5149010266	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	11/17/2015 12:00:00 AM	ADDRESS	34.05379	-118.24909	T-24, TI TO AN (E) HIGH RISE BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN OFFICE SPACE LOCATED AT THE SECOND FLOOR.  TOTAL SQ. FT. 948.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73857	18041-20000-14586	380 WORLD WAY T 71-74	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLANCHECK FOR T24 ENERGY. SIGN LIGHTING. P.F. CHANGSS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73858	10041-10000-03892	11361 W NATIONAL BLVD	90064	11	120B153   448	4258016001	C2-1VL, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2712.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.02569	-118.43304	Plan check power and energy for Ralph's Grocery store remodel.  Plan check did not approve any circuit connections to panel P3 and did not approve the pull box as in note 36 on page E-1.3, or the installation of any pull boxes.  Inspector please verify correct box  size.  Automatic lighting controls shall be certified based on the 2008 California Energy Standard, Section 119.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73859	14041-20000-00203	1100 N BANNING BLVD	90744	15	033B209   587	7423020046	RD6-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Apartment			01/03/2014 12:00:00 AM			PC Approved	01/29/2014 12:00:00 AM	ADDRESS	33.78533	-118.25813	Electrical remodel of the community room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73860	14041-10000-22912	2160 N LAKE SHORE AVE #B	90039	13	145-5A211 287	5420008002	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Apartment			08/22/2014 12:00:00 AM			Reviewed by Supervisor	09/10/2014 12:00:00 AM	ADDRESS	34.0924	-118.25255	PV1, INSTALL 3.75 ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(15) MODULES: CANADIAN SOLAR CS6-250PX(1) INVERTER: SOLAREDGE SE3800A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73861	19041-20000-10857	12244 W OXNARD ST PV1	91606	2	177B165   746	2340003017	RD3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Apartment			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/20/2019 12:00:00 AM	ADDRESS	34.17921	-118.4005	Plan check for PV roof mounted system, system size: 1.83KW with 6 PV modules and 6 microinverters. Unit number 1.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73862	19041-20000-53404	2915 W EXPOSITION PL Unit #3	90018	10	117B185  1312	5044011026	CM-1-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2342.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	06/17/2020 12:00:00 AM				NEW ROOF MOUNTED 3.2KW PV SYSTEM WITH 10 @ 320W PANELS AND A CENTRAL INVERTERS ON AN APARTMENT BUILDING FOR UNIT #3.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73863	15041-20000-10039	12465 W OSPREY LANE Unit # 3	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	33.97923	-118.41018	Plan check for PV roof mounted system for tri-plex unit #3 with system size: 1.84kW. PV clearance shall be relevent to Permit # 15041-20000-10020	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73864	14041-10000-05813	9301 N TAMPA AVE #173	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/04/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Ti in an existing retail store. EPC is for T24. (US Polo retail space.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73865	18041-20000-41765	8711 W VENICE BLVD	90034	10	123B169   810	4312004028	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2702.00	Electrical	Electrical	Commercial			10/31/2018 12:00:00 AM	11/16/2018 12:00:00 AM		Issued	11/16/2018 12:00:00 AM	ADDRESS	34.03271	-118.38284	ti to an existing medical office existing panel.  plan check for power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73866	19041-20001-11183	12746 W JEFFERSON BLVD Suite 3100-3150	90094	11	102B161  1167	4211033012		West Los Angeles				2756.02	Electrical	Electrical	Commercial			09/11/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	09-11-2019 Changes to an approved set of plan, Changes include relocation of equipment(MS3-B) location and interconnection point, connect directly to existing pull section. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73867	19041-20000-10397	8333 N KENTLAND AVE	91304	12	192B097   374	2004005005	RE9-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.22041	-118.61822	pv1install roof mounted pv system sized 7.6KW AC with battery 5KW interconnected with msp.Note: Permit fee $2.00 due to CA Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73868	13041-10000-34899	265 W WORLD WAY	90045	11	090B165    82	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM	05/21/2014 12:00:00 AM		Permit Finaled	05/29/2014 12:00:00 AM	PIN	33.94447227	-118.40494652	REMODEL OF EXISTING DWP BUILDING (UNMANED, EQUIPMENT ONLY) : NEW ROOF TOP MECHANICAL UNITS,   addition of two AHUs to tye roof of the ladwp customer swervice stationj	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73869	16041-10000-25683	3515 W WASHINGTON BLVD	90018	10	126B189   820	5072021012	[Q]CM-1VL-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM			PC Approved	05/08/2017 12:00:00 AM	ADDRESS	34.04006	-118.32302	PC FOR POWER. SERVICE UPGRADE FROM 400A TO 800A 120/240 3 PHASE 4W FOR A WHOLE SALE FOOD PREPARTION CENTER . METHANE ZONE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73870	19041-20000-37037	16700 W SCHOENBORN ST	91343	12	192B137   254	2689011009	M2-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			09/17/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Issued	10/10/2019 12:00:00 AM	ADDRESS	34.22247	-118.4965	$0 FEE PER AB1414 STATE ORDINANCE.PV3 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING COMMERCIAL LOW RISE BUILDING. SYSTEM SIZE IS 52.875 KW DC/39.67KW AC. SCOPE OF WORK CONSISTS OF (141) PV MODULES WITH OPTIMIZERS, (2) 14.4 KW INVETERS, A 11.4 KW INVERTER, 112.5 KVA TRANSFORMER, A 125A SUB PANEL,	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73871	17041-10000-44240	1848 S CRESCENT HEIGHTS BLVD	90035	10	126B173   437	5066009010	R1R3-RG	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	01/03/2018 12:00:00 AM	ADDRESS	34.04277	-118.37477	Permit fee is $6.59 due to Senate Bill 1222.PC FOR ROOF MOUNTED PV1 ON SFD. TOTAL SYSTEM SIZE 10KWAC AND 14.0KWDCSCOPE INCLUDES 35 MODULES WITH OPTIMIZERS AND CENTRAL INVERTER AND NEW LOAD CENTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73872	11041-10000-03383	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			02/22/2011 12:00:00 AM	02/22/2011 12:00:00 AM		Permit Finaled	10/31/2011 12:00:00 AM	ADDRESS	34.21585	-118.47965	TI IN AN EXISTING OFFICE AREA IN THE NORTH EAST CORNER OF THE WAREHOUSE AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS,	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73873	13041-10000-07221	432 S CURSON AVE TOWER 50	90036	4	135B177   134	5509004005	R4-2-O	Central	Wilshire	Mid City West		2145.03	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM	04/26/2013 12:00:00 AM		Issued	04/26/2013 12:00:00 AM	ADDRESS	34.0673	-118.35362	Service upgrade to 4000A for a 13-story apartment building (Tower 50).  Install new switchboards, feeders, house panels, and replace unit panels.  All the existing branch-circuit conductors to be remained and reconnect to the replacement unit panels.  No work done on branch circuit equipment and lighting.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73874	17041-20000-02715	1357 N LAUREL WAY	90210	5	147B161   335	4355018041	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	09/11/2020 12:00:00 AM	ADDRESS	34.09596	-118.41781	Plan check for power only. Project site is a new 2-story single family dwelling over 1 level of basement and detached garage.Note: Building application has been generated under 15010-30000-02333	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73875	14041-20000-03433	22471 W SUENO ROAD	91364	3	168B101   221	2075038012	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			Reviewed by Supervisor	02/21/2014 12:00:00 AM	ADDRESS	34.15904	-118.6159	Roof mounted PV system with 6KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73876	16041-30000-35119	801 S FIGUEROA ST 9TH FLR	90017	14	129A207   119	5144022063	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM			PC Approved	10/04/2016 12:00:00 AM	ADDRESS	34.04789	-118.26153	Title 24 plan check.  Remodel existing restroom on the 9th floor in existing office building.  New lighting and receptacles.  Total area = 640 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73877	14041-20001-22853	18322 W BLYTHE ST	91335	12	189B125   467	2102015049	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM			PC Approved	09/22/2014 12:00:00 AM	ADDRESS	34.21463	-118.53247	EXPEDITE FEESPV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 9.8KW AC USING THE ENPHASE M215. 46 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73878	18041-30001-38032	1680 N VINE ST STE#1000	90028	13	148-5A189 136	5546029001	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM			PC Approved	10/30/2018 12:00:00 AM	ADDRESS	34.10133	-118.32648	This is plan check only for removal of a note on lighting fixture schedule sheet E-4.0 per inspector's request. Changes noted as Delta-2. Other information are remainn the same. Permit is still cover under master.<<PC FOR OFFICE TI IN HIGH RISE (10TH FLOOR) FOR T24 ENERGY ONLY. THIS IS AN HISTORIC BUILDING TO BE VERIFIED AN EXEMPTION FROM MADATORY EM. SYSTEM (GENERATOR). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 5064 SQ.FT>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73879	17041-20000-13022	10250 W CONSTELLATION BLVD 16th flr	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	03/08/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy and em lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73880	11041-20000-25584	2196 W VENICE BLVD	90006	10	126B193   307	5074018001	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.02	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM			PC Approved	12/01/2011 12:00:00 AM	ADDRESS	34.04339	-118.3061	T.I.  for existing beauty salon.  Remodel of the light fixtures and adding receptacles.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73881	16041-10001-08199	11852 N BALBOA BLVD SUITE B103	91344	12	216B133   474	2610002048	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			05/26/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.28546	-118.50127	"(TI) change of use from office to take-out restaurant ""Caesar Pastry"". This is PC only for T-24, express permit pulled under 16041-10000-08199.B#15016-10000-25077"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73882	18041-20002-48381	611 S WESTERN AVE	90005	10	135B193   910	5503031006	C2-2	Central	Wilshire	Wilshire Center-Koreatown		2117.04	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	34.06305	-118.30927	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET. MINOR CHANGES TO ALL PAGES EXCEPT TO POWER AND KITCHEN. CLOUDED DELTA 2 CHANGES ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73883	12041-20002-19547	14006 W RIVERSIDE DR #265	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			10/03/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	34.15713	-118.43792	Supplemental Permit to modify a previously approved set of plans.<<<T-24 lighting plan check for remodeled TENANT IMPROVEMENT OF (E) RETAIL STORE. ALL WORK PER ARCHITECTS DESIGN.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73884	18041-10000-17804	777 S SANTA FE AVE FLOOR 3-5	90021	14	124-5A217 364	5166013010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	07/26/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.03354	-118.23024	PLANCHECK FOR POWER AND ENERGY. Tenant Improvement at levels 3, 4, 5 to existing office space.  62,623 SQFT. (planchecker to verify fees)building permit # 17016-10000-30634	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73885	18041-10000-11007	2810 S CARDIFF AVE	90034	5	126B165  1089	4309020002	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	34.03753	-118.39484	PV1. NEW SOLAR SYSTEM ON EXISTING ROOF-TOP. TOTAL SYSTEM SIZE IS 5.795KWdc / 3.80KWac.(19)MODULES-HANWHA Q-CELL. Q PEAK-G4.1(19)OPTIMIZERS-SOLAREDGE P320(1)INVERTER-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73886	16041-10000-00904	12700 W MILLENNIUM # 51	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1. SOLAR ROOF MOUNTED SYSTEM USING AC MODULES TO A TRACT HOME. 6 AC MODULES AND  AN EXTRA CIRCUIT FOR AN AC MODULE SUPERVISOR MONITOR. TOTAL SIZE: 1.5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73887	11041-10000-13068	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	11/21/2011 12:00:00 AM		Permit Finaled	02/06/2013 12:00:00 AM	PIN	34.12750533	-118.21285206	NEW 1,124 KW PV SYSTEM.  PANELS ARE STAND ALONE IN THE PARKING LOT OF OCCIDENTAL COLLEGE.  PLAN CHECK IS FOR POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73888	17041-10000-30400	3939 S FIGUEROA ST	90037	9	115-5A201  35	5037027910	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	01/17/2019 12:00:00 AM	ADDRESS	34.01173	-118.28296	TI TO KITCHEN ON FIRST AND SECOND FLOOR AREAS. PC FOR POWER AND ENERGY. NEW DISTRIBUTION EQUIPMENT FOR KITCH LOADS AND LIGHTING. B#17016-10000-21655	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73889	15041-20001-10971	1355 N GARDNER ST	90046	4	147B177  1280	5550024015	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			04/15/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.09593	-118.35301	Supplemental application for expedite fees only.  Installation of new roof mounted solar PV array.  Total system size = 14 kWac.  Single inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73890	19041-10000-45381	13727 W CHANDLER BLVD	91401	4	171B157    61	2247014049	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.16872	-118.43212	NEW ROOF MOUNTED 13.2 KW PV SYSTEM WITH 40 PV MODULES AND ENPHASE MICRO INVERTERS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73891	18041-10000-32055	625 E ANAHEIM ST	90744	15	030B209     8	7423024032	[Q]M2-1VL-O-CUGU, [Q]RD3-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			08/22/2018 12:00:00 AM	04/18/2019 12:00:00 AM		Issued	04/18/2019 12:00:00 AM	ADDRESS	33.78052	-118.25524	Plan check for adding a FVD for a 1750HP motor. Medium voltage located in ahazardous location.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73892	11041-20000-24831	10860 W SANTA MONICA BLVD	90025	5	129B153   536	4321001001	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM			PC Approved	11/18/2011 12:00:00 AM	ADDRESS	34.04944	-118.43681	T.I.  Existing 7-11.  24 hr operation.  Remodel of light fixtures in the retail area.  Replacing existing fixtures with LED fixtures.  Plan check is for enery only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73893	15041-20002-19062	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM			PC Approved	07/16/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	07-16-2015 Change to approve set of plan. Changes include manufacturer of the track light and reduce number of fixtures D to 3 fixtures[[[[[Title 24 plan check only.  Total area = 936 sq. ft.  T.I. to existing retail space.  New lighting and recepticles.  Emergency lights and exit signs to remain existing.]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73894	16041-10001-36322	10250 W SANTA MONICA BLVD STE. 1140	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	**6th corrections:1. single line diagram still inconsistent with the approved base  plan2. feeder undersized3. New panel LP isn't shown on riser diagram4. series rated short ckt mfg. cut sheet is needed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73895	15041-20001-16323	936 S OLIVE ST UNIT 346	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM			PC Approved	08/04/2015 12:00:00 AM	ADDRESS	34.04287	-118.25873	Expedited per customer request.Permit #19 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(10) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73896	18041-10000-18491	8732 N TAMPA AVE	91324	12	195B117   134	2784003058	(Q)M2-1VL	North Valley	Northridge	Northridge South		1153.02	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	05/30/2018 12:00:00 AM	ADDRESS	34.22904	-118.55337	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73897	18041-20002-45062	1617 N CASALE ROAD	90272	11	132B133    39	4425001012	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM	01/23/2019 12:00:00 AM		Issued	01/23/2019 12:00:00 AM	ADDRESS	34.06141	-118.50295	01-11-2019 Changes to an approved set of plan, Changes include changes PV system to central inverters, 2 inverters(6.0KW and 10.0KW) with 52 PV Modules, System size: 20.54KW DC, 16.0KW AC. $0.00 permit fee due to State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73898	14041-20000-08318	515 S FIGUEROA ST 5TH FLOOR	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.05199	-118.25764	5th floor office tenant space improvement.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73899	14041-20000-06462	5055 W WILSHIRE BLVD 4th Floor	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.06235	-118.34036	T.I. to existing building on 4th floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 14041-20000-04713	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73900	18041-10001-47412	737 N ORANGE DR	90038	5	141B181   401	5525007024	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM			PC Approved	12/26/2018 12:00:00 AM	ADDRESS	34.08453	-118.34172	PC FOR PV SYSTEM. SYSTEM SIZE IS 4.225 KW PV ARRAY + 13.5 KHW ENERGY STORAGE SYSTEM. 13 PV MODULES (SOLAR CITY SC325) W/SOLAREDGE OPTIMIZER. INVERTER MODEL (SE3800H-US000SNU2). ENERGY STORAGE SYSTEM MODEL (TESLA POWER WALL-120/240V)14KHW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73901	17041-10000-22809	2500 S SANTA FE AVE	90058	14	117A217    89	5168026015	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.01503	-118.23017	TITLE 24 ONLY SCOPE INCLUDES - REMOVE HID FIXTURES(21) AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA (24304 SQ. FT.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73902	16041-10001-31676	1048-1050 N MANZANITA ST	90029	13	145-5A201 413	5427006028	R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Apartment			06/15/2018 12:00:00 AM	11/09/2018 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.0918	-118.2818	[[6/15/18 CHANGES TO APPROVED SET. DELTA 2 CHANGES. ADDITION OF A FIREPUMP AND JOCKEY PUMP DUE TO LOW WATER PRESSURE REQUIREMENT]]]9 UNIT APARTMENT. PC FOR POWER AND ENERGY. FIRE ALARM VARIANCE HAS BEEN FILED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73903	17041-30000-44049	19625 W SHADOW GLEN CIR	91326	12	217-5A117 100	2701009046	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			12/07/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.29172	-118.56156	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (1) load center, and (25) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73904	13041-20000-20681	14006 W RIVERSIDE DR #229	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	"Plan check for energy and emergency lighting. STE 229. Select Comfort.Nonstructural interior T.I. of (E)28'-8"" x 90'-9"" retail space within shopping mall"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73905	10041-10000-22066	3900 N STANSBURY AVE	91423	5	162B153   353	2274027003	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	11/04/2010 12:00:00 AM		Permit Finaled	11/18/2010 12:00:00 AM	ADDRESS	34.14084	-118.44264	REPLACE AN EXISTING DEFECTIVE FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73906	17041-20001-09901	12601 W PIERCE ST Bldg 16	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM			PC Approved	01/30/2018 12:00:00 AM	ADDRESS	34.27174	-118.40738	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 16).5kW ungrounded system. (10) AP Systems YC500i microinverters. (20) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73907	14041-20000-26991	2011 E ZONAL AVE	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM			Reviewed by Supervisor	11/14/2014 12:00:00 AM	ADDRESS	34.06159	-118.20463	PC FOR POWER ONLY. NEW HV DISTRIBUTIION AND NEW SERVICE EQUIPMENT FOR THE BUILDING. NO CHANGE IN LOADS. ONLY CHANGE OF ELECTRICAL LIKE FOR LIKE WITH NEW EQUIPMENT. PER APPLICANT. NO PATIENT CARE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73908	15041-20000-26151	1919 S HARVARD BLVD	90018	10	126B193  1000	5074032011	[Q]R4-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.02	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/20/2015 12:00:00 AM		Permit Finaled	03/10/2016 12:00:00 AM	ADDRESS	34.03923	-118.30454	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (29) modules, and (29) power optimizers. Standard plan is not being used.Note: Solar clearance, City Hist. Cultural Monument, HPOZ, and Hist. Property Cntrct Mgr are refeer to Application # 15041-20000-23335	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73909	14041-10000-04305	345 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	06/24/2014 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.05424	-118.25562	Change of use for a portion of the first 4 floors of hotel to private school (grade 9-12) with basement and basement mezzanine use as auditorium. Classroom on the first floor and second floor dormitories on first floor mezzanine level and 3rd floor. (New light fixtures of 1371 are replaced on existing 277 v ckt. )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73910	16041-10000-02087	1025 S STANFORD AVE	90021	14	124-5A211 328	5132009019	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	07/19/2019 12:00:00 AM	ADDRESS	34.03336	-118.24926	FULL PC, CHANGE OF USE FROM EXISTING WAREHOUSE TO WHOLESALE MALL; NEW 2000AMP SERVICE, ADDING 79 PANELS.  ADDING MEZZANINES ON 1ST AND THIRD FLOOR, AND NEW ROOF TOP GARAGE. TOTAL SQ. FT. 71716	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73911	17041-10000-12624	426 S SEPULVEDA BLVD 1-9	90049	5	135B145   422	4366032026	[Q]R3-1	West Los Angeles	Westwood	Westwood		2654.20	Electrical	Electrical	Apartment			04/18/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Issued	07/18/2017 12:00:00 AM	ADDRESS	34.06672	-118.46047	Installation of new roof mounted solar PV array on existing 3 story apartment building.  Total system size = 23 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73912	16041-20001-16708	3400-3404 W SUNSET BLVD	90026	13	144A203   344	5427026021	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.02	Electrical	Electrical	Apartment			03/20/2018 12:00:00 AM			PC Approved	04/06/2018 12:00:00 AM	ADDRESS	34.08744	-118.27608	3/20/2018changes to an approved set of plans.  changes include structural redesign of the 1st and 5th floor.  all changes noted delta 2.  plan check for power and energy. building application #15010-10005-02786 (((Plan check for New apartment 35 units mixed use building. Service 2000A.  Fire alarm variance has been filed.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73913	17041-20001-44785	5805 N SEPULVEDA BLVD Suite #400	91411	4	174B145   102	2243001009	M1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM			PC Approved	01/26/2018 12:00:00 AM	ADDRESS	34.17593	-118.46647	01/26/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Clarifications were made regarding the use of the EM lighting relay. *****Previous Work Description*****PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES TO 4TH FLOOR. SUITE 400.  14836 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73914	19041-20001-22600	8401 N VAN NUYS BLVD #15	91402	6	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.04	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM			PC Approved	08/27/2019 12:00:00 AM	ADDRESS	34.22308	-118.44896	08-27-2019 Changes to an approved set of plan, Changes include remove lighting fixtures, update lighting fixture schedule wattage and update Title 24 calculation. All changes has been clouded as delta 1. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73915	15041-10000-36194	200 WORLD WAY TERM 2-LEV 1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/28/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	03/31/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	change out luminaires in new storage area/corridor at Terminal 2 Lev 1 at LAXPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73916	14041-10000-00036	701 E NEW DOCK ST M&R-BLDG	90731	15	024B209   298	7440021914	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/02/2014 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.75567	-118.25325	NEW FIRE ALARM SYSTEM FOR M&R BLDG, CONSISTING OF 115 DEVICES, 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73917	18041-20000-21513	4800 S AVALON BLVD	90011	9	111A207    96	5108009027	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Zapata-King		2292.00	Electrical	Electrical	Apartment			06/08/2018 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	01/07/2021 12:00:00 AM	ADDRESS	33.99952	-118.26503	Plan check for power and energy. Project site is a new 5-story, 33-unit apartment building. Building consists of 4 levels of residential  over 1 level of parking garage. Work includes a 1,200 amp service and a total lighting area of 12,673 sq. ft.Note: Building application has been generated under 18010-10000-01856.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73918	17041-20000-34917	19550 W CANTARA ST	91335	3	192B117   913	2105002008	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.21901	-118.55965	Plan check for solar pv system, roof-mounted array on SFD.12kW ungrounded system [(2) 6kW]. (60) 265W pv modules.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73919	10041-20001-19114	1801 CENTURY PARK EAST #800	90067	5	135B161    49	4319002045	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM			PC Approved	12/06/2010 12:00:00 AM	PIN	34.0621869	-118.41581732	PLAN CHECK ONLY. REVISION TO APPROVED PLANS TO SHOW EXIT SIGNS AND EMERGENCY EGRESS LIGHTING CKT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73920	18041-20001-40235	6936 N PEACH AVE	91406	6	183B145   480	2234024027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2018 12:00:00 AM			PC Approved	10/27/2018 12:00:00 AM	ADDRESS	34.19675	-118.46824	Expedited plan check fee. PV1.  Install 12.96 kW roof mounted grid tied PV system.  (36) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73921	16041-20001-02878	7900 N BALBOA BLVD BLDG 'H'	91406	6	189B133   403	2205006904	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.21347	-118.50092	4.13.2016 - Plan check for modifications to approved set. Change size of breakers feeding panels G3, G4, G5, G7, and G8 from 40A to 60A, and update each panel's feeder sizes. Remove T.C. detail from sheet E-5.===Plan check for power and energy Aircraft Hangar Building 'H' per Article 513 ONE 15565 SW FT AIRCRAFT HANGERR, BUILDING ' H' W/  ONE STORAGE ROOM, AND TWO SMALL OFFICES: ONE STORY 70' X 263' W/ TEN HANGERS WITH TWO PARKIGN SPACES PROVIDED IN EACH HANGAR  INCLUDING PARKING STRIPING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73922	13041-20000-29092	8451 W HILLSIDE AVE	90069	4	148-5A175 271	5558028037	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.10047	-118.37255	PV1 NEGATIVELY GROUNDED SYSTEM. TOTAL SYSTEM SIZE 24KW. 96 MODULES AND 2 INVERTERS$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73923	12041-20000-16195	12243 W BRANFORD ST BLDG D	91331	6	201B165    28	2537015063	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM	08/31/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	PIN	34.25127853	-118.40048138	"Relocate main 3000A panel ""MSB"" to a new location with the existing utility service.  Plan check for power and energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73924	12041-20000-01984	14623 W HILLTREE ROAD	90402	11	126B129   889	4409026037	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2012 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.0373	-118.51604	New roof mounted P.V. system with 8.6KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73925	17041-10000-29440	500 N CENTER ST	90012	14	130-5A217 215	5173020010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.05189	-118.23128	PC for T24 energy only, replace outdoor existing fixtures with LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73926	16041-20000-42356	10300 W VENICE BLVD 1-6	90232	5	117B165    21	4208005037	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Apartment			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.02072	-118.40287	Plan check for a fire alarm system. System consists of (1) FACP, (1) annunciator, and (145) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73927	15041-10000-23277	10880 W WILSHIRE BLVD	90024	5	132B153   378	4325005083	C2-1, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/21/2015 12:00:00 AM	08/06/2015 12:00:00 AM		Permit Finaled	11/06/2015 12:00:00 AM	ADDRESS	34.05885	-118.44283	REPLACEMENT OF (2) WATER CHILLERS AND (2) CHILL WATER PUMPS.  PLAN CHECK FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73928	16041-10002-04043	15909 S ORCHARD AVE	90247	15	069B197   130	6120014020	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	33.88687	-118.28838	PC only per inspector request.  Permit under 16041-10000-04043(30) KU2656ZPA Ref: 16041-10001-04043(1)  PVI-3.6-OUTD(1) PVI-3.0-OUTD <<PV1, rooftop solar 6.0kW AC. Standard plan is used.(28)MODULES- KU2656ZPA(1)INVERTER- PVI-6000-OUTD>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73929	15041-10000-25076	3342 N VERDUGO ROAD	90065	1	153A215   258	5456001046	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			08/04/2015 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	06/22/2016 12:00:00 AM	ADDRESS	34.11279	-118.23548	SERVICE UPGRADE 600 AMPS TO AN EXISTING COMMERCIAL BUILDING.  NEW FEEDERS, PANELS, CIRCUITS AND EQUIPMENT.  FULL PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73930	15041-20001-28642	916 S VICTORIA AVE	90019	4	132B189   885	5090034024	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.05619	-118.32338	Expedited per customer request.PV1. Install roof mounted PV system sized 4.2 kW. Interconnected with main service panel.(17) LG280 Modules(1) PVI-4.2 Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73931	10041-20000-22464	1933 S BROADWAY 4TH Floor	90007	9	123A207     2	5126031010	[Q]M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2240.20	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	11/09/2010 12:00:00 AM		Permit Finaled	12/30/2010 12:00:00 AM	ADDRESS	34.03006	-118.26696	TI IN AN EXISTING OFFICE ON THE 4TH FLOOR.  PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73932	12041-10001-27929	1418 N BROAD AVE	90744	15	036B205   965	7422009804	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2941.10	Electrical	Electrical	Commercial			05/17/2013 12:00:00 AM			PC Info Complete	05/17/2013 12:00:00 AM	ADDRESS	33.79195	-118.26154	MODIFICATIONS TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 12041-10000-27929. DELTA 2 TROUGH 4 CHANGES ARE CLOUDED ON SHEETS 6.0 AND 6.1. MAJOR CHANGE: CIRCUIT LENGTHS INCREASED. NOTE TO INSPECTOR: PER APPLICANT UL REP WILL BE ON SITE FOR MODIFIED SWITCHBOARD 'MS'.****************************************************************************New 300kw Fuel Cell System for an existing commercial low-rise building.  Site is in a Methane zone.  The designer has indicated that they will install the system to comply with Methane Level V.  The area is considered a Class 1 Division 1 area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73933	16041-20001-15171	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			05/03/2017 12:00:00 AM			PC Approved	05/03/2017 12:00:00 AM	ADDRESS	33.78808	-118.29535	[[[5/3/17 CHANGES TO APPROVED T24 ONLY. CHANGES TO THE OUTDOOR FIXTURE TYPE ]]]PLANCHECK FOR T24 ENERGY. LIGHTING FOR CARPORTS. 56, 950 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73934	18041-30000-17335	200 WORLD WAY TERMINAL 2-4th floor	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			PC Info Complete	05/24/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	Full plan check for a 4th floor addition on an existing 4-story terminal 2 with new lighting and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73935	19041-20000-13128	857 N DETROIT ST Lot 10	90046	5	144B181   850	5525003023	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2019 12:00:00 AM	05/11/2021 12:00:00 AM		Permit Finaled	12/18/2021 12:00:00 AM				NEW 800A SERVICE FEEDING 10 SFD; PART OF A 10 LOT SMALL LOT SUBDIVISION, ALL SFD'S ELECTRICAL PERMITED UNDER BUILDING COMBO PERMITS, PLAN CHECK FROM UTILITY TO SUB PANELS ONLYBUILDING PERMIT FOR LOT WHERE SERVICE EQUIPMENT IS LOCATED18010-30000-01596	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73936	16041-10003-45090	1301 W 7TH ST	90017	1	130-5A205 108	5143013022	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			10/10/2019 12:00:00 AM	10/15/2019 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.05249	-118.26766	Changes to an approved set of plans, changes revising load calculations, and panel schedules to reflect as built.Also adding new circuitry for washer/dryers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73937	11041-20001-24255	5112-5118 W JEFFERSON BLVD	90016	10	120B177   742	5047001003	[Q]M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			07/19/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	04/04/2013 12:00:00 AM	ADDRESS	34.02537	-118.35568	Change from previously approved plans.  Upgrade service to 800A (no changes in lighting).*****PLAN CHECK T24 ENERGY FOR EXISTING COMMERCIAL BUILDING.*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73938	16041-10000-07565	837 N NORTH SPRING ST 2ND FLR	90012	1	135A215   307	5408031001	C2-2	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			03/03/2016 12:00:00 AM			PC Approved	03/03/2016 12:00:00 AM	ADDRESS	34.06303	-118.23651	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 2ND FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR THE 2ND FLOOR OFFICE SPACE. TOTAL AFFECTED AREA IS 5,252 SQ. FT.NOTE: PERMIT PAID UNDER PCIS#16041-10000-00560 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73939	16041-20000-33702	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.08363	-118.32191	Plan check for energy only. Remodel of some offices and restrooms on 2nd floor of existing office building. New lighting and receptacles. 854sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73940	12041-20000-14603	3337 W PICO BLVD	90019	10	129B189   992	5081022027	C4-1-O	Central	Wilshire	Olympic Park		2131.00, 2213.01	Electrical	Electrical	Commercial			06/22/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Finaled	01/18/2013 12:00:00 AM	ADDRESS	34.04732	-118.31703	T.I. to coin laundry.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73941	14041-10000-29098	1200 N CHICKORY LANE	90049	11	141B137   120	4493025008	RE15-1-H, RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2014 12:00:00 AM	12/11/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.08085	-118.4859	Permit fee is 0.00  due to  Senate bill 1222. PV1.  Install 20.4 kW roof-moutned, utility-interactive PV system.  (2) transformerless inverters with (80) modules and power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73942	18041-20000-15073	4531 W HOLLYWOOD BLVD	90027	4	147B197   594	5542003021	C2-1D	Central	Hollywood	Los Feliz		1953.00	Electrical	Electrical	Apartment			04/24/2018 12:00:00 AM	01/29/2020 12:00:00 AM		Permit Finaled	09/16/2022 12:00:00 AM	ADDRESS	34.099	-118.28806	New 3000A and 4000A 208Y/120V 3ph-4w services, distribution, power and lighting for new mixed use construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73943	17041-20000-14699	20838 W EXHIBIT CT	91367	3	177B109   129	2149012050	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM			Reviewed by Supervisor	05/17/2017 12:00:00 AM	ADDRESS	34.17822	-118.58678	GROUNDMOUNTED PV SYSTEM.  PV1. SYSTEM SIZE: 13.8 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73944	14041-10001-23457	21820 W BURBANK BLVD	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM			PC Approved	10/30/2014 12:00:00 AM	ADDRESS	34.17228	-118.6032	EXPEDITED PER APPLICANTS REQUEST.PHASE 2  : PV2 ROOF MOUNTED SOLAR SYSTEM. (1)  SMA 15TL  INVERTER (132) YINGLI YL 295 MODULES PHASE 1: E13LA03534	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73945	12041-20001-30859	21728 W VENTURA BLVD	91364	3	171B105    41	2168024064	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.16814	-118.60169	Installing track lighting in an Existing Yoga Studio.  Not a first-time tenant and not a place of assembly per applicant.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy, Emergency lighting is on application 12041-20002-30859.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73946	17041-10000-06476	16450 W GERMAIN ST	91344	12	207B137   718	2679005009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Issued	02/28/2017 12:00:00 AM	ADDRESS	34.26185	-118.49087	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac.(34)MODULES-HANWHA Q-CELL Q PLUS-BFR-G4.1(34)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE7600A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73947	13041-10000-19749	2684 W MOSS AVE	90065	1	150B213   100	5457016007	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.03	Electrical	Electrical	Apartment			07/25/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	11/04/2013 12:00:00 AM	ADDRESS	34.11118	-118.23813	PV1 3.43 KWdc 240V changed to XFRMless  ground. 2STORY. nonSTD. ROOFMOUNT.  [*( 1) INV: POWERONE PVI-3.0-OUTD-US *] [( 14) MOD: TRINA {TSM-245PC05.18} ] 3 of 3 13041 10000 19749 (2684 moss ave)for reference:1 of 3 13041 10000 19738 (2682 moss ave)2 of 3 13041 10000 19746 (2682 1/2 moss ave)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73948	18041-10000-07502	360 E 2ND ST STE. 350	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/01/2018 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	Pc for T24 only for office TI for suite 350. Installing new two new panels, lights, receptacles and equipment. B# 18016-10000-05460.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73949	18041-10000-48525	8201 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.21793	-118.6063	PC FOR FA. SCOPE INCLUDE 143 DEVICES AND 1 CENTRAL FACP FOR STRIP MALL 2ND TIME TENANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73950	11041-20000-19637	307 N BERENDO ST	90004	13	138B197   259	5520021007	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Apartment			09/15/2011 12:00:00 AM			PC Approved	09/15/2011 12:00:00 AM	ADDRESS	34.0767	-118.29454	Existing four unit apartment building to be converted to 8 units.  Ttal load is less than 400 AMPS.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73951	16041-20002-31279	10231 W MCBROOM ST	91040	7	207B181   309	2543007022	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2016 12:00:00 AM			PC Approved	11/16/2016 12:00:00 AM	ADDRESS	34.26483	-118.35253	"[[[ CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 2 CHANGES. ADDING OF DIVERSION CHARGE CONTROLLER, DIVERSION LOAD AND BOLLARDS ]]""0$ permit fees due to senate bill 1222 ""BATTERY STORAGE SYSTEM  + PV1 ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.16 KW"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73952	17041-20001-31154	6330 N LAUREL CANYON BLVD	91606	2	180B165   800	2334003031	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			08/30/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	04/19/2018 12:00:00 AM	ADDRESS	34.18575	-118.39631	Change of use from retail to adult daycare center and office.  Main hall occupant load is 222 occupants per building permit - plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73953	17041-10000-28996	11761 W ROSCOE BLVD	91352	6	192B169   438	2633031902	[Q]PF-1XL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1218.02	Electrical	Electrical	Commercial			08/16/2017 12:00:00 AM	01/18/2018 12:00:00 AM		Issued	01/18/2018 12:00:00 AM	ADDRESS	34.22177	-118.38982	Note: Permit Fees are $0 due Senate Bill 1222.New PV system installed on car port, LADWP building 166 KW, 704 modules, 6 inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73954	13041-10000-03080	23680 W SCHOENBORN ST	91304	12	192B093   324	2005020030		North Valley	CHATSWORTH			1132.31	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2013 12:00:00 AM	02/07/2013 12:00:00 AM		Permit Finaled	05/29/2013 12:00:00 AM	ADDRESS	34.22063	-118.64372	PV1 for single story house. [Inverter used: Fronivs Model#: IG PLUS V10.00] [Solar Module used: Trina Solar Model#:TSM-240-PA-05]. System size: 10.56 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73955	12041-20001-13284	8365 W 3RD ST	90048	5	138B173   758	5511015017	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM			PC Approved	07/02/2012 12:00:00 AM	ADDRESS	34.07307	-118.37236	Changes from previously approved plans.  Change in type of light fixtures.  Plan check for energy only.*****T.I. to beauty salon.  Install general/emergency lighting.  Plan check for energy only. *****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73956	17041-10002-45508	2810 E WHITTIER BLVD	90023	14	123A223   177	5189004019	[Q]C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM			PC Approved	06/06/2018 12:00:00 AM	ADDRESS	34.0315	-118.20975	Changes to an approved set of plans. All changes are clouded under delta 1. Changes include relocating ac disconnects, and a transformer to an exerior wall, and revising conductor sizes on the single line diagram.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73957	17041-10000-24569	18620 W VENTURA BLVD	91356	3	174B121   644	2161015013	C2-1VL	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.16987	-118.53933	PC power and energy for LA fitness TI. PC includes new 1600A service, three new panels, new circuits and equipment. Total affected area is 24536 sqft. Building # 17016-10000-16949.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73958	14041-10000-20326	8113 N ST CLAIR AVE	91605	2	189B165   112	2309012007	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	Commercial			07/29/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Expired	08/30/2016 12:00:00 AM	ADDRESS	34.21813	-118.39994	PV1. STANDARD PLAN. ROOF MOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.67 KW DC. UNGROUNDED.(34) TRINA SOLAR #TSM-255 MODULES(1) PVI 3.6 POWER ONE AURORA(1) PVI 3.0 POWER ONE AURORA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73959	16041-10000-20686	1061 S BROXTON AVE	90024	5	132B149    64	4363024005	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			06/13/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.06138	-118.44636	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING(RESTAURANT). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING RESTAURANT. TOTAL AFFECTED AREA IS 1478 SQ. FT. B#16016-10000-12511	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73960	19041-10000-28012	3920 W SUNSET BLVD	90029	13	145-5A203 376	5427007031	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			07/22/2019 12:00:00 AM			PC Info Complete	07/22/2019 12:00:00 AM	ADDRESS	34.092	-118.2802	POWER AND ENERGY PLAN CHECK FOR A TI-CHANGE OF USE FROM RETAIL TO MEDICAL OFFICE (PRESCRIPTION GLASSES/ OPTOMETRY).  SCOPE INCLUDES NEW LIGHTING, RECEPTACLES AND CONTROS. ALL ELECTRICAL CIRCUITS ARE CONNECTED TO EXISTING 100A PANELBOARD.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
73961	19041-10000-34097	16619 W MARQUEZ TER	90272	11	129B121   568	4419014021	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.04864	-118.54412	[EPLAN] PV1. PLAN CHECK FOR 11.4KVA PV SYSTEM CONSISTING OF 1 CENTRSAL INVERTER(SE11400H-US) WITH 34 MODULES USING P400 OPTIMIZERS CONNECTED TO EXISTING 200A SERVICE  MAIN BREAKER DERATE SHALL BE DONE UNDER SEPARATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73962	19041-10000-18036	1779 E 109TH ST	90059	15	088-5A215 621	6069004030	R2-1	South Los Angeles	Southeast Los Angeles	Watts		2427.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	33.93719	-118.24087	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 11 MODULES (Q-CELL 325), 11 POWER OPTIMIZERS (SE P370) AND CENTRAL INVERTER (SE 3000H-US).  SYSTEM SIZE IS 3.575 KWdc AND 3KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73963	18041-20000-04598	3673 N BERRY DR	91604	2	162B173   923	2378025030	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			02/07/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	PIN	34.13738075	-118.37867973	Note: $0.00 permit fee due to CA Senate Bill 1222Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (33) modules, (33) micro-inveters, (3) load centers, and (2) Tesla PowerWalls. Submitted per applicant request.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73964	11041-10000-25972	1160 W HARRY BRIDGES BLVD DRIVER SER-BLDG	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	12/04/2014 12:00:00 AM	PIN	33.77046453	-118.27163726	METHANE  MITIGATION AT DRIVER SERVICES BLDG WHICH IS  PART OF TERMINAL EXPANSION THAT INCLUDES  ABOUT SEVEN NEW BUILDINGS AT BERTHS 136 THRU 139LEVEL 5 METHANE MITIGATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73965	15041-20000-25314	345 S BROADWAY	90013	14	130-5A211 134	5149015020	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/06/2015 12:00:00 AM			PC Approved	08/11/2015 12:00:00 AM	ADDRESS	34.05008	-118.2492	Title-24 plan check only.  Total area = 1,206 sq. ft.  T.I. to existing commercial space.  New lighting, recepticles, and kitchen equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73966	11041-20001-01877	330 S LA CIENEGA BLVD	90048	5	138B173   831	5511032047	C2-1VL-O, P-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	34.07282	-118.37627	PLAN CHECK FOR REVISION TO APPROVED PLANS. CHANGES ARE CLOUDED ON PLAN. ADDITIONAL PANEL FOR GUARDHOUSE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73967	15041-10000-38247	810 E PICO BLVD #101	90021										Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.03119	-118.25079	T-24, TI TO AN (E)  RETAIL BUILDING SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL SQ. FT. 850	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73968	15041-10002-24106	8224 N WEBB AVE	91605	6	192B169   508	2310005010	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM			PC Approved	12/29/2016 12:00:00 AM	ADDRESS	34.22011	-118.39142	12/30/16PV1, changes to approved set of plans. Changes include upgrading the house panel size to 200 amps, and changing conductor sizes for the pv interconnection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73969	19041-10002-00182	3475 S STONER AVE	90066	11	117B153  1102	4249015003	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	02/09/2019 12:00:00 AM	ADDRESS	34.01339	-118.43259	SUPPLEMENTAL PLANS CHECK FOR ( DELTA 2 ) CHANGES TO APPROVED SET - CHANGES INCLUDE INCREASING THE NUMBER OF MODULES FROM 19 TO 22(SOLAR CITY SC325) AND ADDING ONE ADDITONAL RAPID SHUTDOWN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73970	17041-20001-32217	3356 N EASTERN AVE	90032	14	142-5A233 174	5218013010	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32		2015.03	Electrical	Electrical	Commercial			09/08/2017 12:00:00 AM			PC Approved	09/21/2017 12:00:00 AM	ADDRESS	34.08505	-118.1779	expeditepv2install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73971	17041-20003-37249	10303 N NORRIS AVE	91331	7	204B165   123	2537005014	M1-1-CUGU, P-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM			PC Approved	07/31/2018 12:00:00 AM	ADDRESS	34.25696	-118.40297	Revisions to approved set.  Revised fire pump supply conductor connection to service, routing and conductor sizing details, and disconnect rating.  (((new fire pump to an existing storage building.  plan check for power only.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73972	10041-10000-08139	1417 N BRONSON AVE	90028	13	147A191   135	5545015012	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			05/03/2010 12:00:00 AM	09/07/2010 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	ADDRESS	34.09618	-118.31811	Electrical service upgrade for existing building (47units, 4 stories and basement).  Install new swtichboard, panels, and branch circuits.  Plan check for energy and power.  Additonal PC fee may require for Title-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73973	12041-10000-23759	5555 W MELROSE AVE BLDG 323-1st Flr	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	10/04/2012 12:00:00 AM		Permit Finaled	11/09/2012 12:00:00 AM	ADDRESS	34.08363	-118.32191	Change to lighting and receptacles for an existing office space in a low-rise building.  Load is less than 400 amps per applicant.  PLAN CHECK ONLY for Energy with Emergency lighting.  BLDG 323 -1st Floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73974	17041-20000-28105	14922 W NAVARRE WAY	91342	7	219B149   981	2611046067		North Valley				1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/09/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.29441	-118.45577	pv1install roof mounted pv system sized 3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73975	13041-10000-19142	6731 N FALLBROOK AVE	91307	3	180B097   107	2038040012	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.19189	-118.62364	FA. existing building. for AMC fallbrook 7. 95 DEVICES. 1 PANEL. 1 AUDIO NOTIFICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73976	17041-20000-36218	5325 S COMPTON AVE	90011	9	108B209   453	5104009030	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Apartment			10/10/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	33.99414	-118.24792	PV2.  Install roof mounted PV system sized 3kW interconnected with unit subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73977	13041-10000-00382	6600 N TOPANGA CANYON BLVD #39	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/07/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	ADDRESS	34.19008	-118.60565	T24 FOR TI - SINGLE STORY RETAIL SPACE.  APPLICANT IS USING TAILORED METHOD.  13,055 SQ FT.  NEW CONNECTED LOAD 46 W. ALL THE SWITCHES, CONTROLS, EMERGENCY & EXIT SIGNS ARE EXISTING TO REMAIN.(The applicant lost marked plan and correction list after correction was issued, PERMIT WILL BE ISSUED @ THE PLAN CHECK)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73978	12041-10000-14554	12506 W WAGNER ST	90066	11	105B157    26	4221005050	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2012 12:00:00 AM	09/10/2012 12:00:00 AM		Permit Finaled	10/12/2012 12:00:00 AM	ADDRESS	33.98792	-118.42177	Plan check for new roof mounted  2.8KW DC photovoltaic system using Solaredge transformerless inverter and DC-DC power box optimizer. Include Misc permit for the power box installation.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73979	14041-20001-00900	20539 W VENTURA BLVD	91364	3	177B101    80	2146003014	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/07/2014 12:00:00 AM			PC Approved	03/07/2014 12:00:00 AM	ADDRESS	33.9787	-118.31759	((plan check for changes to approved set of plans. removal of uneeded occupancy sensors and emergency egress on central inverter circuit. all changes clouded )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73980	10041-20000-09861	951 S HEMLOCK ST	90021	14	123A213   235	5130001028	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	05/26/2010 12:00:00 AM		Permit Finaled	10/13/2010 12:00:00 AM	ADDRESS	34.03025	-118.24467	energy plan check retail	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73981	15041-20000-27196	5224 E GRANADA ST	90042	1	151-5A225  62	5469018021	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.11101	-118.20179	PV1. Install roof mounted PV system sized 5 kW. Interconnected with main service panel.(15) Sunpower E20-327 Modules(1) PVI 5.0 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73982	16041-10000-00112	5185 E BORLAND ROAD	90032	14	138A235   256	5221003018	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2017.00	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM	01/04/2016 12:00:00 AM		Permit Expired	02/02/2018 12:00:00 AM	ADDRESS	34.07178	-118.17153	PV1, rooftop solar installation 3kW AC(8) KD255GX-LFB3(1) PVI-3.0-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73983	13041-20000-16710	1923 S BRONSON AVE	90018	10	126B185  1048	5060006013	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2187.01	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM			Corrections Issued	06/24/2013 12:00:00 AM	ADDRESS	34.03922	-118.33029	"CONSTRUCTION OF NEW SIGN FOR OUTDOOR DISPLAY. PC FOR T24 ENERGY ONLY FOR SLTG FORMS. SIGN ""FRESH BROTHERS"". CONTAINS 3 DRIVERS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73984	12041-10000-06465	1700 S LINCOLN BLVD	90291	11	111B149  1302	4242010031	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	Commercial			03/21/2012 12:00:00 AM			PC Approved	03/21/2012 12:00:00 AM	ADDRESS	33.99682	-118.45798	revisions to existing retail store-new luminaires and circuitsPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73985	19041-20000-31191	15108 W ROMERO PL	91343	7	198B145   238	2656022***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2019 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.23848	-118.46153	Plan check for PV roof mounted system, PV system size: 7.92KW DC, 7.396KW AC with 24 PV Modules and 1 inverter(7.6KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73986	15041-20001-39150	120 E 68TH ST	90003	9	102B205   300	6011004004	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.20	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM			PC Approved	01/22/2016 12:00:00 AM	ADDRESS	33.97776	-118.27306	Change to approved set of plans. Changes include layout of the module on the roof. {{{{{{{{{PV1, roof mounted solar panel, 7.6 kW AC system   (31)modules: SUNEDISON270,   (1)inverter: SE7600A-US.  ((Submittal per applicant))}}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73987	15041-20000-03437	18528 W CHASE ST BUILDING A	91324	12	192B125   315	2785018029	R3-1	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Apartment			02/04/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	05/30/2017 12:00:00 AM	ADDRESS	34.22434	-118.53707	PC FOR 11 UNIT APARTMENT. TOTAL UNITS ON LOT 28. THIS IS SUBMITTAL 1 OF 2. THIS PLAN CHECK IS FOR 11 UNITS LOCATED AT BUILDING A. BOTH BUILDINGS ARE SERVED BY A SINGLE UTILITY TRANSFORMER.PC IN ACCORDANCE TO 2008 BUILDING EFFICIENCY STANDARDSFIRE ALARM VARIANCE HAS BEEN FILED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73988	15041-20003-31594	12056 N ADELPHIA AVE	91340	7	216B161   105	2514005038	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM			PC Approved	02/17/2016 12:00:00 AM	ADDRESS	34.28948	-118.41235	02/17/2016 Changes to an approved set of plans. PV inverter power rating has been reduced to 3.8 kWac.01/15/2016 Changes to an approved set of plans. Changes have been made to reflect field installation. Module count has increased by (1) and inverter size has increased to 5 kWac.*****Previous Work Description*****PV1Install a roof mounted solar array on a SFD. Interconnect with a 100A MSP.Ungrounded system. Using 300W power optimizers (1 per module). (18) 260W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73989	13041-10000-34518	6206 N BABCOCK AVE	91606	2	177B161   388	2332017002	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.18329	-118.4062	PV1, Install  4.25 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (17) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73990	15041-20001-19704	10201 N GAVIOTA AVE	91343	12	204B141   551	2669008005	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2015 12:00:00 AM			PC Approved	06/30/2015 12:00:00 AM	ADDRESS	34.25567	-118.48279	Expedite per applicant request[[[[[Plan check for PV roof mounted system. Total system size: 5.4kW system and 24 modules and 24 microinveters.]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73991	19041-20000-23906	834 S SHENANDOAH ST	90035	5	132B169    29	4333013007	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Apartment			06/21/2019 12:00:00 AM	08/11/2020 12:00:00 AM		Permit Finaled	01/11/2023 12:00:00 AM	ADDRESS	34.06193	-118.3812	Plan check for power and energy for 4 story building 5 units Multi-family, 600A Service, Total area: 1480 sqft. #B18010-10000-05350	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73992	13041-20001-21228	12200 W VENICE BLVD	90066	11	114B157  1475	4235023001	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM			Corrections Issued	09/02/2014 12:00:00 AM	ADDRESS	34.0046	-118.43132	PLAN CHECK FOR CHANGE IN SERVICE RISER WIRE SIZE AND AIC RATING OF SERVICE EQUIPMENT ONLY. CHANGES HAVE BEEN CLOUDED. NEW RISER SIZE NOW 2 SETS OF 4#500 CU. AND AIC RATING OF SERVICE NOW 65KA. NO OTHER CHANGES MADE. THIS IS PLAN CHECK ONLY. NO PERMIT TO BE SSUED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73993	16041-20000-14403	17150 W NANETTE ST	91344	12	222B133   635	2602019057	RE11-1-HPOZ	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.30167	-118.50599	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(41) LG NEON MODULES(41) POWER OPTIMIZERS(1) SOLAREDGE INVERTER 11400W	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
73994	19041-10000-15795	1429 S LOS ANGELES ST B	90015	14	124-5A207 319	5133012011	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Issued	04/30/2019 12:00:00 AM	ADDRESS	34.0341	-118.26102	REPLACE INDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY. UNIT B	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
73995	15041-10000-18221	680 S PARK VIEW ST	90057	1	133-5A203 110	5141003900	OS-1XL	Central	Westlake	MacArthur Park		2088.01	Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Info Complete	07/31/2015 12:00:00 AM	ADDRESS	34.05844	-118.28014	PC FOR ENERGY, OUTDOOR PARK LIGHITNG. TAPPING INTO UNDERGROUND FEEDERS.  TOTAL SQ. FT. 7800.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
73996	19041-20000-43932	15559 W COVELLO ST	91406	6	186B141   150	2222016038	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.20756	-118.4726	PV1. INSTALL 4.88 KW DC/4.38 KW AC PV SYSTEM WITH (16) MODULES, PV LOAD CENTER, AND (8) MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73997	19041-10000-44503	4406 W 28TH ST	90016	10	123B185   955	5050016015	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.03098	-118.33681	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 3.8KWac/4.275KWdc.SCOPE OF WORK INCLUDES 15 MODULES (HANWHA Q-CELL Q PLUS 285W) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE3800H-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73998	19041-10000-08728	6509 W DE LONGPRE AVE PNL A	90028	13	147A187   250	5546014016	C2-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	09/28/2020 12:00:00 AM	ADDRESS	34.09625	-118.33056	PC FOR PV , SCOPE INCLUDE 18 MODULES(SPR-E20-235-COM) W SOLAREDGE OPTIMIZERS. 1 SOLAREDGE SE7600H INVERTER . 1 DISCONNECT SWITCH. cONNECTED TO PNL A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
73999	15041-10000-32561	221 N VENDOME ST	90026	13	138A201    43	5156009018	RD1.5-1	Central	Westlake	Rampart Village		2086.10	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2015 12:00:00 AM	10/01/2015 12:00:00 AM		Permit Finaled	12/23/2015 12:00:00 AM	ADDRESS	34.074	-118.28095	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.STANDARD PLAN CENTRAL STRING INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74000	15041-10000-43090	427 W 5TH ST	90013	14	129A211    12	5149028012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/14/2016 12:00:00 AM	03/22/2017 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.04937	-118.25245	FULL PC, NEW 23 STORY 347 UNIT RESIDENTIAL APARTMENT BUILDING WITH RETAIL ON THE FIRST FLOOR AND 2 FLOORS OF GRADE PARKING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74001	15041-10001-01503	13843 W OSBORNE ST	91331	6	198B153   900	2642029007	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.23567	-118.43526	CHANGES TO AN APPROVED SET OF PLANS.  ADDING TWO MODULES KYOCERA KD255GX-LFBB.6/12/2015- PERMIT PULLED UNDER INSPECTION FEES. -AIPlan check for PV1 roof mounted, system size: 3.6 kWac with 16 modules. Using standard plan.Reason for Submit over the counter: Unable to submit online due to load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74002	19041-10000-05929	10959 W KINROSS AVE	90024	5	132B149    99	4363025001	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.05	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM			PC Info Complete	02/19/2019 12:00:00 AM	ADDRESS	34.06012	-118.44693	PLAN CHECK FOR TITLE 24 ONLY FOR MIXED USED BUILDING. TOTAL EFFECTED AREA 758 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74003	18041-20000-20184	5327 N DONNA AVE	91356	3	171B121   147	2163022027	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.16783	-118.54858	Plan check for a PV1 roof-mounted PV system. System size is 10.4KVA consisting of (2) inverter - solivia 5.2TL, (38) modules, and (1) load centers. with battery backup system under supplemental	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74004	17041-20000-05587	16127 W KITTRIDGE ST	91406	6	180B141   393	2233029008	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.05	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.1904	-118.48467	PV1.  Install 5.2 kW roof mounted grid tied PV system.  Central inverter standard plan.  (20) modules with (1) 5.2 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74005	15041-20000-35527	1415 N DEVLIN DR	90069	4	144B169    34	5560037018	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM	12/09/2015 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.09476	-118.38664	Plan check for power single family dwelling 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74006	16041-30000-23041	6705 N RESEDA BLVD BLDG 1	91335	5	180B125   200	2126034023	OS-1XL	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.19218	-118.53631	REMOVE EXISTING HID FIXTURES AND REPLACE WITH NEW LED LIGHTING FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 5875.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74007	17041-20001-23281	9958 N ETON AVE	91311	12	204B105   794	2747007056	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2017 12:00:00 AM			PC Approved	07/19/2017 12:00:00 AM	ADDRESS	34.25177	-118.59498	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.21 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74008	19041-20001-28647	1371 NORTH AVENUE 46		7	210B193   263	2551038016	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	08/14/2019 12:00:00 AM	PIN	34.27204232	-118.30839609	expeditepv1install roof mounted pv system sized 9.1KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74009	11041-10000-26842	7703 W MELROSE AVE	90046	5	141B177   549	5527008028	C4-1XL-O	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			12/16/2011 12:00:00 AM	12/29/2011 12:00:00 AM		Permit Finaled	11/02/2012 12:00:00 AM	ADDRESS	34.08389	-118.35765	T.I. to an existing retail building.  No suite number.  New lights and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74010	15041-20000-27377	14534 W SATICOY ST 1-26	91405	6	186B149   214	2218003015	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM	09/02/2015 12:00:00 AM		Permit Expired	09/28/2017 12:00:00 AM	ADDRESS	34.20831	-118.45021	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74011	18041-10000-05384	6701 S CENTER DR WEST	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	PC FOR TITLE 24 ENERGY ONLY FOR TI: RENOVATION OF (E) 2ND FLOOR DECK AND LOBBY WITH OUTDOOR LIGHTS IN CAMPUS STYLE. SCOPE INCLUDES NEW LIGHTS , CIRCUITS AND RECEPTACLESTOTAL  AFFECTED AREA 2344+3507 SQ.FT  (INDOOR AND OUTDOOR)B#17016-10000-36282	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74012	18041-20000-40367	15301 W VENTURA BLVD 3rd Floor	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM			PC Approved	10/22/2018 12:00:00 AM	ADDRESS	34.15411	-118.46654	TI to (E) commercial office suites and adjoining corridor. Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74013	12041-10000-03100	10322 N ENCINO AVE	91344	12	204B129   134	2733023037	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2012 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.2584	-118.51521	New rooftop photovoltaic system for an existing single family residence, 7.8kw.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74014	12041-10000-08541	17112 W MINNEHAHA ST	91344	12	207B133   997	2695019033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2012 12:00:00 AM	04/13/2012 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.26007	-118.50588	Rooftop PV system, SFD, 8.175 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74015	13041-20000-22291	14006 W RIVERSIDE DR	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	T24 FOR EXISTING MALL. TOTAL NEW CONNECTED LOAD LESS THAN 400A. 15300 SQRFT. SCOPE OF WORK IN THE COMMON AREA OF THE MALL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74016	10041-10000-17694	217 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			Reviewed by Supervisor	02/24/2012 12:00:00 AM	ADDRESS	34.04919	-118.22722	Solar voltaic system installed on the roof of the building.  Consists of  6 modules,  6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74017	13041-20001-25448	13154 W CROWLEY ST	91331	6	195B157   743	2627024029	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM			PC Approved	09/20/2013 12:00:00 AM	ADDRESS	34.22995	-118.41946	((changes to approved set of plans. only 1 string of 7. pc for changes only. permit already issued under original application)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING 13 MODULES. 2 STRINGS. TRANSFORMERLESS INVERTER NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74018	19041-10000-13255	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/11/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Issued	10/30/2019 12:00:00 AM	ADDRESS	33.79173	-118.23549	power pc for refinary, existing service. adding (4) 200A and (3)400A panels. (2) 400hp motors and (2) 500kva transformers. service is 2400v,1200A, 3ph, 3Wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74019	14041-10000-17639	617 W 7TH ST 10th floor	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.04779	-118.2571	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICIES. HIGH RISE.  10TH FLOOR.  12543, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74020	19041-20000-29280	16574 W BOSQUE DR pv1	91436	5	165B137   434	2291007021	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			07/29/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	08/15/2019 12:00:00 AM	ADDRESS	34.1462	-118.49508	pv1install roof mounted pv system sized 7.6KW AC interconnected wih msp.(1) LG chem battery rated 5KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74021	14041-10000-17423	1875 S CENTURY PARK EAST	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	ADDRESS	34.06115	-118.41457	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR THE PANTRY ROOM ON THE 23RD FLOOR. 724 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74022	17041-20000-28025	12355 W EMELITA ST	91607	2	174B165    99	2340008030	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	09/28/2017 12:00:00 AM	ADDRESS	34.17641	-118.40253	Plan check for the addition PV system onto an existing PV1 roof-mounted PV system. System addition size is 5.2 kWac and consists of (1) inverter, (21) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74023	19041-20000-41158	5408 W PICO BLVD	90019	10	129B177  1030	5069030002	C4-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	09/23/2021 12:00:00 AM	ADDRESS	34.04831	-118.35623	TENANT IMPROVEMENT FOR A RESTAURANT P.C FOR T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74024	18041-10000-06133	350 S GRAND AVE 11TH FL-12TH FL.	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	04/06/2018 12:00:00 AM	ADDRESS	34.05173	-118.2522	PC FOR TITLE 24 ENERGY ONLY FOR  INTERIOR REMODEL TO THE (E) OFFICE BUILDING, UPGRADE RESTROOMS TO ADA STANDARDS ON THE 11TH AND 12TH FLOORS. TOTAL AFFECTED AREA 1326 SQ.FT.B# 18016-20000-	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74025	11041-10000-17454	1230 W 3RD ST 2nd fl	90017	1	132A209    97	5152014037	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			08/17/2011 12:00:00 AM	08/17/2011 12:00:00 AM		Permit Finaled	03/12/2012 12:00:00 AM	ADDRESS	34.057	-118.259	remodeling officesplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74026	19041-10000-37493	11806 W VENICE BLVD	90066	11	114B157   956	4214017023	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Commercial			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Issued	09/19/2019 12:00:00 AM	ADDRESS	34.00799	-118.42529	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74027	17041-20000-16715	10604 N LOUISE AVE	91344	12	207B133   736	2695005007	R1-1XL-RFA	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/20/2017 12:00:00 AM	ADDRESS	34.26264	-118.51085	pv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74028	10041-20000-25793	266 N QUADRO VECCHIO DR	90272	11	126B117   129	4416024052	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2010 12:00:00 AM			PC Info Complete	02/15/2011 12:00:00 AM	ADDRESS	34.04369	-118.55969	PLAN CHECK FOR NEW SINGLE FAMILY DWELLING WITH 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74029	11041-10000-06916	11321 W MISSOURI AVE	90025	11	126B149   509	4261021013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			04/07/2011 12:00:00 AM	06/17/2011 12:00:00 AM		Permit Finaled	06/29/2012 12:00:00 AM	ADDRESS	34.04226	-118.44566	New 9 units appartment Bldg. New 600 Amp service, panels, and circuits. EPC is for power & energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74030	14041-20000-04061	11944 N SIERRA LANE	91326	12	216B121   240	2872004022	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM			Reviewed by Supervisor	03/04/2014 12:00:00 AM	ADDRESS	34.28945	-118.55078	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 225 MAIN SERVICE PNL. TRANSFORMERLESS SYSTEM, SIZED @ 8.5 kW DC, WITH (34) TRINA SOLAR TSM-250W MODULES, (34) SOLAREDGE OPTIMIZERS OP300-MV, (2) SOLAREDGE INVERTERS, SE5000-US-ZB-U, SOLAREDGE SE3000A,-US-ZB-U, (1) 125A LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74031	16041-10000-01201	3316 S KELTON AVE	90034	5	120B161   709	4254017003	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Expired	02/12/2018 12:00:00 AM	ADDRESS	34.02477	-118.41858	PV1, Install 11.66 kWdc / 10.0kWac roof-mounted solar array, interconnect with service panel. Transformerless. (1) Inverter. : FRONIUS IG PLUS A 10.0,  (44) Modules KYOCERA KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74032	11041-10003-05711	5555 N VAN NUYS BLVD	91411	4	174B149   958	2249001018	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1288.02	Electrical	Electrical	Commercial			11/01/2012 12:00:00 AM			PC Approved	11/01/2012 12:00:00 AM	ADDRESS	34.1717	-118.44906	Modificaiton to approved set of plans for lighting and circuit changes.           <<<<<<4,306 SF CHASE BANK BUILDING.  Full plan check requested by applicant.>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74033	13041-10001-05748	380 WORLD WAY Space T45	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/20/2013 12:00:00 AM			PC Info Complete	08/20/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	Original plans were lost.  A copy of the approved set was provided for restamping.   Master plan has been checked against load calculations - load is within range of master plan.   Plan check only.  (((PROPOSED 709 SQFT  TENANT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE (Petrossian).)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74034	16041-10000-26379	12100 W WILSHIRE BLVD #430	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.0438	-118.46755	PC for title 24 only for 1526 sqft for commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74035	09041-10001-19521	3400 S FIGUEROA ST	90007	9	120A203   222	5123022040	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/28/2010 12:00:00 AM			PC Approved	01/28/2010 12:00:00 AM	ADDRESS	34.02167	-118.2799	Revision to approved plans, remove two A/C units and 4 FC units and increase the size of the remaining A/C and FC units.  Also junction boxes were added for each sign circuit.((((ON-SITE TWO-SIDED SIGN FOR GALEN CENTER ONLY WITH AN AREA OF SIGN NOT TO EXCEED 768SF  FOR A LED MESSAGE BOARD))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74036	12041-10000-10554	1150 S GRANVILLE AVE	90049	11	129B145   653	4265010048	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	05/08/2012 12:00:00 AM		Permit Finaled	06/06/2012 12:00:00 AM	ADDRESS	34.04901	-118.46305	Upgrade/New Fire Alarm system for an existing 6-unit apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74037	17041-10001-28774	11980 W FOXBORO DR	90049	11	132B141   273	4404018028	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			PC Approved	09/29/2017 12:00:00 AM	ADDRESS	34.05968	-118.47423	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74038	13041-10000-00024	19854 W REDWING ST	91364	3	174B113   507	2164010031	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2013 12:00:00 AM			Reviewed by Supervisor	01/08/2013 12:00:00 AM	ADDRESS	34.17046	-118.56553	PV1 SOLAR ARRAY INSTALLATION 2.40 KW 2 STORY HOUSE. 10 MODULES IN SINGLE STRING.[MODULES: REC {REC240PE(BLK)}] [MICROINVERTER: ENPHASE ENERGY MICRO-INVERTERS M215-60-2LL-S22]APPLICANT DID NOT SUBMIT STANDARD PLAN, BUT WAS AWARE OF ITS EXISTENCE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74039	19041-10000-21555	401 E M ST	90744	15	036B209   611	7422017900	OS-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2946.10	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/13/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	33.78924	-118.25841	INSTALL NEW FIRE ALARM SYSTEM FOR A MUSEUM. 107 FA DEVICES. ONE FA  PANEL AND ONE CONTROL PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74040	12041-10001-08126	17031 W GUNTHER ST PV-1	91344	12	213B133   130	2607002033	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2012 12:00:00 AM	06/26/2012 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	34.28343	-118.50347	PLAN CHECK FOR INSTALLATION OF 6 KW ROOF MOUNTED ENPHASE M215 MICROINVERTER PHOTOVOLTAIC SYSTEM. ADDITIONAL PERMIT FOR MICROINVERTERS AND LOAD CENTER PANEL NOT COVERED ON ORIGINAL PERMIT #12041-10000-08126.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74041	16041-10001-03732	4954 N WHITE OAK AVE	91316	5	168B129   767	2290010024	(T)RS-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2016 12:00:00 AM			PC Approved	04/11/2016 12:00:00 AM	ADDRESS	34.16089	-118.518	This is PC only.  Line side tap for PV connection per NEC 705.12(A) and 230.82(6), added Fuses within the AC disconnect. Permit under 16041-10000-03732Zero fees $0 due per California Senate Bill 1222.<<PV1, SOLAR ROOF MOUNTED SYSTEM USING MICRO-INVERTERS. (46) MODULES AND (46) MICROINVERTERS AND (100AMP) LOAD CENTER WITH A MONITORING SYSTEM. TOTAL SIZE 11.5KW-AC.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74042	12041-10000-27910	11920 W SAN VICENTE BLVD	90049	11	129B145   158	4265007035	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM			PC Info Complete	11/20/2012 12:00:00 AM	ADDRESS	34.05237	-118.47062	plan check for power, water heater and lighting..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74043	15041-20000-05960	7645 N VARIEL AVE	91304	3	186B105    67	2109025012	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.2095	-118.59302	Installation of new roof mounted solar PV microinverter array.  Total system size = 5.16 kWacNote: PV Plan check over the counter because B contractor can not pull permit online	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74044	12041-20000-29673	6321 N ZELZAH AVE	91335	12	177B129    50	2123022025	R1-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2012 12:00:00 AM	01/24/2013 12:00:00 AM		Permit Finaled	02/05/2013 12:00:00 AM	PIN	34.18438257	-118.52323036	PV-1. Plan check for PV-system. 10.47kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74045	13041-10000-03377	555 S FLOWER ST FLR 51	90071	9	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/12/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	05/28/2014 12:00:00 AM	ADDRESS	34.05048	-118.25755	TI  ON  51ST FLOOR AND ADDITION OF MEZZ AND KITCHEN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74046	12041-20000-00802	19767 W RINALDI ST	91326	12	210B117   381	2701040041	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			01/12/2012 12:00:00 AM			PC Info Complete	01/17/2012 12:00:00 AM	ADDRESS	34.27501	-118.56446	T.I. to retail space.  Install indoor general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74047	18041-20002-26522	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	33.96577	-118.42406	"12/28/2018changes to an approved set of plans.  changes to reflect field conditions to the following panels 2PUR, 2PURA, 2PMC, 2PMCA AND 2PMCB. ""PCR"" changes only.This is plan check only.((((11/28/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta PCC. Changes have been made to reflect field conditions. Loads have been relocated and sub panels have been removed.))))*****Previous Work Description*****PC FOR TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING FOR POWER AND ENERGY (LOYOLA UNIV).SCOPE INCLUDES NEW CONNECTED LOAD >400A. SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL CONNECTED AREA 20694 SQ.FT  B# 18016-10000-19140"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74048	19041-20000-15163	5808 W SUNSET BLVD LEVEL 12	90028	13	147A191    79	5545016009	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			04/24/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/31/2019 12:00:00 AM	ADDRESS	34.09782	-118.31646	T24 ONLY PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL LEVEL 12. LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 300SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74049	16041-10000-35631	12035 W WATERFRONT DR 1ST FLOOR	90094	11	105B161  1201	4211011029	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	11/21/2016 12:00:00 AM		Permit Finaled	12/15/2016 12:00:00 AM	ADDRESS	33.98233	-118.40556	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES ADDING NEW LIGHTS FOR AN EXISTING OFFICE SPACE. TOTAL AFFECTED AREA IS 718 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74050	14041-20000-22167	23355 W CALIFA ST	91367	3	174B093    11	2041006014	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	01/12/2015 12:00:00 AM	ADDRESS	34.17683	-118.63612	PV1.  Install 7.020 kW roof-mounted, utility-interactive PV system.  Central inverter with low frequency transformer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74051	17041-20001-46604	11848 N JELLICO AVE	91344	12	216B129   380	2601042033	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	Yes	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2018 12:00:00 AM	11/13/2018 12:00:00 AM		Permit Finaled	12/18/2018 12:00:00 AM	ADDRESS	34.28477	-118.51719	Revisions to approved set.  (E) branch circuits to be relocated to (N) 400A distribution downstream of MSP. (((PLAN CHECK FOR GROUND MOUNTED PV SYSTEM. SYSTEM SIZE 11.4KW CONSISTING OF 1 CENTRAL INVERTER (SE 11400A-US) WITH 36 MODULES AND POWER OPTIMIZERS(P370).BUILDING PERMIT IS REQUIRED)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74052	19041-10000-11154	19191 S VERMONT AVE 640	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	PC for Tenant improvement Energy only to an office space in a high rise.  Total affected area is 1,322 sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74053	13041-10000-14806	12311 N LONGACRE AVE	91344	12	219B125   189	2601075071	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	09/16/2013 12:00:00 AM	ADDRESS	34.29293	-118.53498	PV1 10.5KW XFMR INV. 2 STORY. NONSTD. ROOFMOUNT. (2)FRONIUS IG PLUS V5.0-1 uni .  [ 42 MOD: TRINA TSM-250PC05.08]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74054	13041-10000-30005	20750 W VENTURA BLVD SUITE 320	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			10/28/2013 12:00:00 AM			PC Approved	10/28/2013 12:00:00 AM	ADDRESS	34.16638	-118.58506	PLAN CHECK FOR TITLE 24 ENERGY ONLY. TENANT IMPROVEMENT ON SUITE 320 ON A TWO STORY OFFICE.  2351 SQFT, EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74055	13041-10000-27137	20200 W TUBA ST	91311	12	204B113   298	2741010011	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Expired	11/09/2015 12:00:00 AM	ADDRESS	34.25592	-118.57369	PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 5.25 kW. TRANSFORMERLESS INVERTER. TWO STORY.(21) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-5000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74056	19041-10000-53542	5755 W SANTA MONICA BLVD	90038	13	144B189   589	5536013002	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			12/27/2019 12:00:00 AM			Reviewed by Supervisor	01/08/2020 12:00:00 AM	ADDRESS	34.09089	-118.31543	FULL PC FOR A CORE AND SHELL, SCOPE INCLUDES A NEW 3000A SERVICE (3P,4W 480/277) THAT FEEDS VARIOUS TRANSFORMERS, DISTRIBUTION EQUIPMENT AND 3 ELEVATORS, NOTE THIS PROJECT COVERS 4 BUILDING THAT HAVE BEEN LOT TIED. TOTAL AFFECTED AREA IS 56,467 SQFT. PER BUILDING ((CORE & SHELL ADAPTIVE REUSE RENOVATIONS.CHANGE OF USE FROM WAREHOUSE /12-UNIT APT TO OFFICE .  (200FT X 150 FT,  56,000 SQ/FT) 19016-10000-40777))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74057	10041-10000-05941	8631 W 3RD ST #530	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			04/01/2010 12:00:00 AM			PC Info Complete	04/01/2010 12:00:00 AM	ADDRESS	34.07373	-118.38036	Plan check power and energy for medical office (suite#530) area remodel at Cedars-Sinai Medical Center. Not plan reviewed for OSHPD III.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74058	10041-20000-01028	1020 S OLIVE ST	90015	9	127-5A209 286	5139012008	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM	03/10/2010 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.04162	-118.2599	fire alarm system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74059	18041-20001-35451	11444 W ALBATA ST	90049	11	135B145   719	4365017008	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2019 12:00:00 AM			PC Approved	05/30/2019 12:00:00 AM	ADDRESS	34.06314	-118.4621	5/30/2019changes to an approved set of plans.  changes to feeder sizes.  this is plan check only.((((Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (3) Tesla PowerWalls onto an existing PV system. Service size is 400 Amps.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74060	15041-10000-08748	462 E COMMERCIAL ST	90012	14	130-5A215  46	5173001905	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/25/2015 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.05309	-118.23584	PC FOR POWER AND ENERGY. NEW 3000 A SERVICE FOR LOS ANGELES DEPT OF TRANSPORTATION FACILITIES CONSISTANT OF MAINTENANCE AND OPERATION BLD, PARKING STRUCTURE, TANK FORM BLDG AND SERVICE BLDG.(MAINTANANCE INCLUDES CLASS ONE DEVISION 2 AREA). TOTAL AREA (INDOOR 36875)  + (67828 OUTDOOR) 104703 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74061	13041-20000-03460	11632 N SPY GLASS DR	91326	12	213B117   103	2822024017	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.28286	-118.55785	new 10.14kw rooftop mounted PV system for a sfr.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74062	19041-10000-45396	2121 S AVENUE OF THE STARS 4TH FLOOR	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	03/06/2020 12:00:00 AM	ADDRESS	34.05554	-118.41342	T-24 ONLY, ENERGY PLAN CHECK. SCOPE INCLUDES NEW LIGHTS FOR AN EXISTING SPACE ON THE 4TH FLOOR. TOTAL AFFECTED AREA IS 3177 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74063	10041-10000-23822	941 W 37TH PL	90089	8	117B197     7	5039012027	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/30/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	34.01943	-118.2897	INSTALL A NEW FIRE/LIFE SAFETY SYSTEM IN THE SALVATORI COMPUTER SCIENCE CENTER BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74064	17041-10000-46580	8520 N WINNETKA AVE	91306	3	192B113   113	2782011024	RA-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.01	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	12/29/2017 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.22515	-118.57083	TITLE 24 PLAN CHECK FOR REPLACEMENT OF EXISTING METAL HALIDE FIXTURES TO NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74065	18041-20000-43115	3518 S TROUSDALE PKWY	90089	9	120A201    86	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			11/09/2018 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	10/09/2020 12:00:00 AM	ADDRESS	34.02157	-118.28415	Plan check for power and energy. Project site is an existing commercial building. Project scope is refeeding distribution equipment from a different medium-voltage power source, installation of new distribution equipment, and replacement of existing sub-panels to meet new AIC rating requirements. No new loads are part of this scope of work. Total lighting area = 1,140 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74066	10041-20000-11885	5300 N LANKERSHIM BLVD #105	91601	4	171B173  1412	2350015114	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	07/08/2010 12:00:00 AM		Permit Finaled	09/01/2010 12:00:00 AM	ADDRESS	34.16715	-118.37571	Plan check power and energy for TI change of use from restaurant to dental office suite #105	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74067	15041-20001-17388	385 E SWINFORD ST	90731	15	021B201   194	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			12/01/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	33.7494	-118.27878	PC FOR FULL BUILDING. TI BUILD OUT. PC FOR POWER AND ENERGY. 600A SERVICE APPROVED AND PERMITTED UNDER MASTER APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74068	11041-10000-05232	10830 W PICO BLVD	90064	5	126B157   947	4255028002	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			03/16/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	34.04014	-118.42803	REMODELING OF EXISTING NORDSTROM STORE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74069	12041-20001-09088	5340 S ALLA ROAD	90066	11	102B157    39	4211008023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			09/28/2012 12:00:00 AM			PC Approved	10/03/2012 12:00:00 AM	ADDRESS	33.9773	-118.42567	Plan check for energy and emergency lighting. Suite 100. 13525 sqft indoor and 1877 outdoor = 15402T.I. to an existing 2-story office building.  Occupant load is less than 99 and load is 391A per applicant.  PLAN CHECK ONLY for T-24, with Emergency lighting.  (All LED lighting to be listed/tested to an Approved testing standard per the applicant - approval shall be provided to inspector.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74070	17041-30002-08124	12900 W VANOWEN ST	91605	2	180B161    77	2326001031	C1-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1234.20	Electrical	Electrical	Commercial			09/28/2017 12:00:00 AM			PC Approved	09/28/2017 12:00:00 AM	ADDRESS	34.19373	-118.41424	09-28-2017 Changes to an approved set of plan. Changes include changes manufacturer from siemens to EATON series ratted. Changes has been clouded as delta 2. Plan check only. Note: Building application has been generated under 16016-20000-25220	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74071	13041-10000-35546	1015 S CROCKER ST STE #Q17	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	12/20/2013 12:00:00 AM		Permit Finaled	02/05/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	TITLE 24 PART 6 ENERGY FOR COMMERCIAL BUILDING.  SCOPE OF WORK IS FOR REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLUORESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 844 SQ FT. REPLACING TOTAL OF 7 UNITS. ALL WORK WILL BE INTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74072	19041-10000-51350	2250 S BARRINGTON AVE	90064	11	123B149   488	4260013028	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM	12/12/2019 12:00:00 AM		Issued	12/12/2019 12:00:00 AM	ADDRESS	34.0331	-118.44665	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHITNG, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 2157 SQFT. TOTAL NEW CONNECTED LOAD IS UNDER 400A. INVESTIAGTION FEES HAS BEEN PAID.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74073	18041-20000-45115	3639 S LUY ROAD	90034	5	117B161   643	4252012038	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.01725	-118.41652	Plan check for a PV1 roof-mounted PV system. System size is 8.72 kWdc/8.5 kWac-CEC and consists of (28) modules, (28) micro-inverters, (2) load centers, and (1) back-up battery.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74074	12041-10000-19832	525 S HEWITT ST	90013	14	126A215    76	5163023900	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM	09/13/2013 12:00:00 AM		Permit Finaled	11/05/2015 12:00:00 AM	ADDRESS	34.04076	-118.2351	Plan check power and energy for existing DWP building (Office/assembly/lab).  New 1200A Service, Switchboard, panels, and loads. Site located in methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74075	17041-10000-15641	14752 W WEDDINGTON ST	91411	4	172-5A149 177	2249019014	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.16656	-118.45487	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE IS 5.52 KWACSYSTEM INCLUDES 16 AC MODULES SUNPOWER SPR-X21-345-C-AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74076	17041-20000-46241	8499 N SUNLAND BLVD	91352	6	192B177   196	2408014027	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM			PC Approved	12/26/2017 12:00:00 AM	ADDRESS	34.22475	-118.36597	ti to an existing commercial spcae.  adding new lighting new controls to new panel. plan check for energy indoor/outdoor only.this is plan check only.permit fees paid under application number 16041-10000-12539	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74077	19041-20000-16370	3149 W LOS FELIZ BLVD	90039	13	157-5A205 179	5594005020	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/02/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	01/25/2021 12:00:00 AM	ADDRESS	34.12417	-118.26775	Plan check for Title 24 energy only in existing space Tenant Improvemetn  restaurant. Total area: 769 sq ft. B#18016-10000-36025	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74078	16041-10000-01259	14006 W RIVERSIDE DR SPACE #220	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT OF EXISTING RETAIL SPACE. TOTAL AREA IS 1033-SQ FEET. SCOPE INCLUDES NEW LIGHTING, RECEPTACLE AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74079	19041-20000-08735	6701 S CENTER DR WEST 4th-restroom	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/12/2019 12:00:00 AM		Permit Finaled	07/10/2019 12:00:00 AM	ADDRESS	33.97907	-118.39369	ti to an existing commercial building.  adding new lighting new control to existing panels.  plan check energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74080	16041-10000-28236	1479 N WESTERLY TER	90026	13	142-5A205  19	5425009007	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	10/04/2016 12:00:00 AM	ADDRESS	34.08667	-118.27129	Installation of new roof mounted PV system on existing single family dwelling.  Total system size = 2.15 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74081	18041-10000-25299	4214 W BEVERLY BLVD 203	90004	10	138B193   494	5518004029	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2114.20	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM			PC Approved	07/06/2018 12:00:00 AM	ADDRESS	34.07613	-118.30086	PLAN CHECH FOR TITLE 24 ONLY FOR - CHANGE OF USE FROM EXISTING RETAIL TO MASSAGE PARLOR - TOTAL AFFECTED AREA 897 SF.7/18/18 : applicant went ahead and pull an expres permit under this scope of work. Therefore, this is plan check only, permit is covered under expres permit# 18041-10000-26794	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74082	15041-20000-42286	748 E 85TH ST	90001	9	097-5A207 235	6029031026	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2398.02	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM	12/16/2015 12:00:00 AM		Permit Finaled	01/21/2016 12:00:00 AM	ADDRESS	33.96089	-118.26121	PV1, rooftop solar installation. interconnect with 200A MSP.(17) SW285 Mono(17) Enphase M250-60-22L-S22-IGStandard plan is used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74083	14041-20002-31995	11249 N BORDEN AVE PV1	91331	7	210B161   214	2536010008	(Q)RD2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	ADDRESS	34.27408	-118.40657	CHANGE IN ROOF LAYOUT AND DC STRING WIRING. NO CHANGE IN AC SIDE OF THE SYSTEM. RECHECK FOR CHANGES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74084	17041-20000-28818	9516 N BADEN AVE	91311	12	201B097   183	2727001031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.24329	-118.61894	0$ permit fees due to senate bill 1222Plan check for solar pv system, roof-mounted on SFD.12.72kW ungrounded system.(53) EnPhase M250 microinverters.(53) 290W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74085	18041-30000-39849	7600 N BALBOA BLVD #112	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	PLANCHECK FOR POWER AND ENERGY. ICE CREAM PARLOR. FIRST TIME APPLICANT. TOTAL AFFECTED AREA IS 947 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74086	18041-10000-47122	846 S MARIPOSA AVE	90005	10	132B197   715	5094017002	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.05	Electrical	Electrical	Apartment			12/12/2018 12:00:00 AM	09/05/2019 12:00:00 AM		Permit Finaled	12/08/2021 12:00:00 AM	ADDRESS	34.05637	-118.29858	Full plan check for a new 7-story 38-unit AFFORDABLE HOUSING apartment  with 1200-Amp 120/240v 3-phase 4-wire service. total 14-typical unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74087	19041-10002-36895	23251 W MULHOLLAND DR	91364	3	168B093   229	2074039031	(Q)CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.15499	-118.63293	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE REPLACING INVERTERS FROM SOLAREDGE TO SUNNYBOY. AND REDUCING THE NUMBER OF MODULES TO 479. REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT.NOTE: PERMIT FEES ARE PAID UNDER PCIS#19041-10000-36895	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74088	14041-20000-34702	13328 W BONANZA ST	91331	7	201B157   507	2622013018	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.24683	-118.4236	PV1 SFD. TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER SYSTEM. USING ENPHASE M215. TOTAL OF 16 MODULES. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74089	19041-10000-52850	5731 W SANTA MONICA BLVD	90038	13	144B189   585	5536013025	CM-1VL	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			12/20/2019 12:00:00 AM			Reviewed by Supervisor	12/31/2019 12:00:00 AM	ADDRESS	34.09089	-118.31466	PC FOR NEW PARKING GARAGE, SCOPE OF WORK INCLUDES NEW 800A, 277/480V, 3PH DISTRIBUTION BOARD FED FROM EXISTING SERVICE. SCOPE OF WORK INLUCDES NEW LIGHTING, PANELS, CIRCUITS, AND EV CHARGERS. TOTAL SQ. FT. 172075.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74090	18041-30001-40433	3828 S CLARINGTON AVE	90232	5	120B165  1295	4207005023	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.02183	-118.39963	12/18/2018 Plan check for Title 24 only. Project site is an exising commercial building. Project scope is a change of use from print shop to office. Total lighting area = 3,086 sq. ft.Note: Building permit has been issued under 18016-30000-22353*****Original Work Description*****REPLACE ONE SINGLE PHASE SUB-PANEL AND ONE THREE PHASE SUB-PANEL; ADD OUTLETS AND SWITCHES TO EXISTING CIRCUITS; ADD 24 LED LIGHT FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74091	13041-10000-27770	1731 N WORKMAN ST	90031	14	135A221    96	5210006009	M2-1VL	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1999.00	Electrical	Electrical	Commercial			10/07/2013 12:00:00 AM	10/07/2013 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.06217	-118.21429	"pc for energy only. CBS not methane. REPLACE (E) 600A/480V AND 300A/240V SERVICES WITH SINGLE 1200A/480V FOr future addition of new loads (444A left on the MSA). old 240V loads to be placed on 400A dist. pnl ""DP"" through 150KVA xfmr. existing loads and feeders to remain."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74092	19041-20000-14872	7865 W SUNSET BLVD	90046	4	147B177   975	5551019021	C4-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM			Verifications in Progress	08/09/2019 12:00:00 AM	ADDRESS	34.09823	-118.36113	new convenience market 600 amps.  plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74093	16041-20001-09549			12	195B133   507	2689018030	R3-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM			PC Approved	05/05/2017 12:00:00 AM	PIN	34.22705349	-118.50207694	Expedited per applicant request.PV2. ROOFMOUNTED SOLAR SYSTEM.  TOTAL SYSTEM SIZE: 364 KW.   TWO BUILDING CONNECTED AS ONE FEED IN TARRIF SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74094	19041-20000-26935	20440 W LASSEN ST	91311	12	201B109   129	2748006031	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/15/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	07/18/2022 12:00:00 AM	ADDRESS	34.24979	-118.57852	$0 permit fee due to sb1222 and ab1414PV3.  Install 518.4 KW DC/470.29 AC CEC PV system.  (1296) modules with (13) 33.3 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74095	14041-10000-28020	12481 W FIELDING CIR	90094	11	102B161  1191	4211034010		West Los Angeles				2756.02	Electrical	Electrical	Commercial			10/09/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.97896	-118.41223	INSTALLATION OF A NEW FIRE ALARM SYSTEM. 1 PANEL 221 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74096	16041-20001-30556	21001 W SATICOY ST	91304	3	186B109   186	2109024020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.20845	-118.5909	EXPEDITE PER APPLICANT REQUEST.Plan check for roof-mounted solar pv system. Interconnect with a 125A MSP. 6kW ungrounded system. Each module has a 300W power optimizer. (18) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74097	16041-20000-06524	2250 E ALCAZAR ST Room 135M	90033	14	135A227    67	5202003023	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	34.06307	-118.2	Renovation of (E) laboratory space and adjacent storage space in Keck School.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74098	11041-10000-00052	750-754 S BROADWAY	90014	14	127-5A209 314	5144015***	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/03/2011 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	02/03/2012 12:00:00 AM	ADDRESS	34.04393	-118.25432	Change of use from  existing general  retail  to restaurant  bar with live entertainment and sale and dispensing of a full-line of alcoholic beverages for on site consumption with  a 5980 S.F. restaurant with live entertainment  per ZA-2009-94-CUB, no dancing.  T24 and emergency lighting and minor power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74099	15041-20000-32721	5939 N COLBATH AVE	91401	2	177B153   961	2246003021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM	10/23/2015 12:00:00 AM		Permit Finaled	11/13/2015 12:00:00 AM	ADDRESS	34.17863	-118.43674	PV1. Install roof mounted PV system sized 3 kW. Adding to an existing system. Interconnected with main service panel.(12) Kyocera KU 265 Modules(1) ABB PVI-3.0 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74100	14041-10000-23964	100 S SANTA FE AVE	90012	14	127-5A217   3	5163017900	(T)(Q)C2-2D, PF-1XL	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/02/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.04798	-118.23239	PROVIDING 2 CONDUIT STOPS FOR FUTURE TENANT SPACES. ADDIN POWER TO GRATITUDE SPACE ELECTRIC ROOM AND  TO GROW SPACE TO ELECTRICAL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74101	14041-10000-19212	3250 W WILSHIRE BLVD	90010	10	132B197    43	5094008027	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			07/17/2014 12:00:00 AM			PC Info Complete	08/05/2014 12:00:00 AM	ADDRESS	34.06162	-118.29337	PLANCHECK FOR POWER DUE TO INSPECTORS REQUEST . REPLACING (8) MOTORS.  METHANE ZONE.  PERMIT PREVIOUSLY PULLED UNDER 14041-10000-14944.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74102	12041-10000-28032	18562 W CALLE VISTA CIR	91326	12	213B125   108	2872020013	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2012 12:00:00 AM	12/12/2012 12:00:00 AM		Permit Finaled	02/01/2013 12:00:00 AM	ADDRESS	34.28303	-118.53794	PV1 ROOF MOUNTED SOLAR INSALLATION. SYSTEM SIZE IS 11.772KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74103	19041-10001-19588	181 S VERMONT AVE	90004	13	138B197  1240	5518030003	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2113.20	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Info Complete	08/14/2019 12:00:00 AM	ADDRESS	34.07061	-118.29189	07/30/2019Changes to an approved set of plans. Changes noted on delta 2 and 3. Scope of work includes the revision of the single line diagram and panel schedule. ______________________________________________________Plan check for power and energy for Tenant Improvement to existing restaurant, Total load exceed 400A, 800A Service existing to remain. Total area: 3030 sq ft. B#19016-10000-11837	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74104	16041-10001-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/10/2017 12:00:00 AM			PC Approved	03/08/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	PC FOR CHANGES TO APPROVED SET. CHANGES UNDER DELTA 1-5. INCLUDES RELOCATION OF CIRCUITS PANELS AND EQUIPMENT. PLAN CHECK ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74105	12041-20000-19404	5581 E HUNTINGTON DR NORT 7	90032	14	147A239   271	5309024018	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2011.20	Electrical	Electrical	Commercial			08/17/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	10/09/2012 12:00:00 AM	PIN	34.09529946	-118.15872155	Plan check for energy and emergency lighting. UNIT #7 in shopping mall. 928 sqft..  ((PERMIT FEES ARE UNDER INSPECTION))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74106	11041-10000-16393	22821 W SATICOY ST	91304	12	186B097   195	2014017019	C2-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.20844	-118.62411	T.I,.  Existing 7-Eleven.  Replacing the flourescent light fixtures with LED light fixtures, using the existing circuits, within the retail area only.  PLan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74107	13041-10001-23415	5636 N TUJUNGA AVE	91601	2	174B173   775	2337039019	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Commercial			12/11/2013 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.1733	-118.37885	TITLE 24 PLAN CHECK ONLY. SQFT 15630. EMERGERGENCY LIGHTING.  1 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74108	15041-10000-37424	909 W TEMPLE ST	90012	14	133-5A211 268	5161001060	C4-2D, R4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.06102	-118.24942	$0 permit fee per senate bill 1222.PV2, ROOF MOUNTED SOLAR SYSTEM FOR AN APARTMENT BUILDING. 331 MODULES AND 4 INVERTERS. TOTAL SIZE IS 86.7-KW(331) WORLDWIDE AS6P305W(2) FRONIUS SYMO 20.0-3 480V WYE(1) FRONIUS SYMO 24.0-3 480V WYE(1) FRONIUS SYMO 22.7 -3 480V WYE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74109	18041-10001-29631	3513 S PURDUE AVE	90066	11	117B157   593	4249028021	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM			PC Approved	09/07/2018 12:00:00 AM	ADDRESS	34.01541	-118.42557	[[CHANGES TO APPROVED SET. ADDITION OF (1) MODULE AND CHANGE FROM SC325 TO SC320]]]Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74110	15041-20000-21527	13140 W MULHOLLAND DR	90210	5	156B157   101	4386010003	RE15-1-H, RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2015 12:00:00 AM			PC Info Complete	08/27/2015 12:00:00 AM	ADDRESS	34.12679	-118.41899	plancheck for a single family resident. 600 amp single phase 120/240 service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74111	18041-20000-35492	6930 N OWENSMOUTH AVE	91303	3	183B105   749	2138007007	(Q)P-1VL-RIO, [Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			09/17/2018 12:00:00 AM			Reviewed by Supervisor	09/27/2018 12:00:00 AM	ADDRESS	34.1965	-118.60139	Plan check for PV roof mounted system, system size: 17.39kW AC with 54 PV Modules and 1 inverter(14.4KW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74112	17041-10000-27653	1336 N WATERLOO ST	90026	13	141A207   141	5424025009	RD3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1956.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.08145	-118.26507	PC for rooftop solar for 6kW PV system with 23 modules and optimizers installed in multifamily housing.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74113	11041-20000-04291	6105-6107 N CLYBOURN AVE Building 6	91606	2	177B177   411	2414021021	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			03/07/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Issued	06/01/2011 12:00:00 AM	ADDRESS	34.18147	-118.35936	Plan check for Building #6.  Upgrade existing service to 600A.   All loads are existing. Installing 8 new panels in the units.   <<< Additional circuits will be installed in the future subject to additional permit>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74114	16041-20000-15155	1716 N WESTERLY TER	90026	13	144A205   153	5431036037	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1955.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.0899	-118.2691	PV1.  Install 1.8 kW rooftop mounted PV system.  (6) modules with (1) 3.0 kW rated inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74115	15041-20001-11928	5698 S GOLDENEYE CT UNIT 3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	33.9792	-118.41068	Expedite per applicant request*****Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL BE RELAVENT TO UNIT # 1 OF ADDRESS 5698 GOLDENEYE CORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74116	18041-10001-23792			9	099B209   385	6029005026	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2398.01	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	PIN	33.96625062	-118.25825735	SUPPLEMENTAL FOR FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE 5.0 KVA CONSISTING OF 1 CENTRAL INVERTER (SUNNY BOY-5.0US) WITH 17 MODULES 2 PV SYSTEMS UNDER SAME PROPERTY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74117	14041-20001-16403	11132 W VENTURA BLVD	91604	2	162B173   371	2378009007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			06/19/2014 12:00:00 AM			PC Approved	07/29/2014 12:00:00 AM	ADDRESS	34.1414	-118.37315	Expedited plan check fee per applicant request.  PV2.  Install 32.94 kW DC roof-mounted, utility-interactive PV system.  (3) transformerless inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74118	16041-20000-06029	6500 N CANOGA AVE	91303	3	180B105    74	2148031018	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Commercial			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.1887	-118.59717	PLANCHECK FOR T24 ENERGY. OUTDOOR LIGTHING RETROFIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74119	19041-20000-41032	11881 W TERRA VISTA WAY #101	91342	7	216B169   126	2526004007	(T)(Q)RD6-1, A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1042.04	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM			PC Approved	04/03/2020 12:00:00 AM	ADDRESS	34.28607	-118.3907	VOID	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74120	14041-10000-15566	525 E 12TH ST STE 101	90015	14	124-5A209 212	5145024020	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM			PC Approved	06/17/2014 12:00:00 AM	ADDRESS	34.03454	-118.25441	permit to be pulled at EPC counter only. Plan check for energy only. TI TO (E) RETAIL. STE 101	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74121	09041-10002-11227	2600 W WILSHIRE BLVD	90057	1	133-5A201 122	5141008900	C4-2	Central	Westlake	MacArthur Park		2087.20	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Info Complete	06/02/2011 12:00:00 AM	ADDRESS	34.06041	-118.28167	Installation of 30 H.P fire pump new 400 amps service and panel for fire pump only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74122	18041-20000-45999	14706-14708 W ARMINTA ST	91402	6	189B149   517	2210021021	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.2133	-118.4533	Commercial office space TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74123	18041-20001-20696	6353 N VAN NUYS BLVD	91401	6	180B149  1035	2241004007	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM			PC Approved	10/02/2018 12:00:00 AM	ADDRESS	34.18585	-118.44901	10-02-2018 Changes to an approved set of plan, changes include replace type lighting fixture in store front and storage area. all changes has been clouded as delta 1 only. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74124	14041-10002-33492	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			07/14/2016 12:00:00 AM	07/25/2016 12:00:00 AM		Permit Finaled	09/02/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	07/14/16PC FOR POWER ONLY. SCOPE INCLUDES ADDING/REPLACING 2 BOOSTER PUMPS, TWO NEW TRANSFORMERS, AND ONE 20HP FIRE PUMP. ALL CHANGES ARE CLOUDED UNDER DELTA 2. CHANGING ENGINEER ON RECORD FOR NEW SCOPE OF WORK. (((((Change to approved set by adding on a 20Hp fire pump and and a 2HP jockey pump; permit under original plan check.per F.Y(((Plan check per applicant request : Power plan check for a New 400-Amp electrical service for domestic water pumps))).	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74125	15041-20000-28594	12346 W VENTURA BLVD	91604	2	162B165   267	2369002021	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			08/31/2015 12:00:00 AM	09/21/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	PIN	34.14266557	-118.40229057	PLANCHECK FOR T24 ENERGY ONLY. CHANGE OF USE FROM RETAIL TO NAIL SALON. 1540 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74126	14041-20000-35565	17809 W SIDWELL ST	91344	12	219B129   653	2601071005	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2014 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.30054	-118.5224	PV1. Install roof mounted PV system sized 10 KW. Interconnected with main service pannel.(44) Sunmodule SW250(1) Solar Edge SE10,000A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74127	18041-20002-01171	1942 N SAN YSIDRO DR	90210	5	150B157   163	4384030012	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2018 12:00:00 AM			PC Approved	04/09/2018 12:00:00 AM	ADDRESS	34.10647	-118.42415	04-09-2018 Changes to a permited set of plan. Changes include remove battery back up PowerWall. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74128	18041-20001-28730	2732 W LOCKSLEY PL	90039	4	151-5A207 185	5438018021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			09/18/2018 12:00:00 AM			PC Approved	09/18/2018 12:00:00 AM	ADDRESS	34.10749	-118.26237	Revision to approved set.  Change of module power rating from 325W to 320W.  $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.  (((Plan check for PV roof mounted system, system size: 7.6kW with 24 pv modules and 2 inverters(3.8kW))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74129	13041-10001-33084	8500 N LOUISE AVE	91325	12	192B133    91	2690015030	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.2253	-118.50967	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74130	16041-20001-32680	5218 E YORK BLVD	90042	14	156A225   400	5478005007	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM	10/14/2016 12:00:00 AM		Issued	10/14/2016 12:00:00 AM	ADDRESS	34.12041	-118.20203	Property was misidentified as 1/2 family dwelling in initial application.  Plans previously approved under standard plan for 1/2 family dwellings.  Plan check fee charged for check of contractor design build set.  Additional permit fees under inspection to cover fee difference arising from change from SFD PV to commercial PV.  Service load calculations are attached to previously approved standard plan for purposes of verifying derated service main rating.  (((Plan check for installation of roof-mounted solar array on SFD. Interconnect with 200A MSP. Derating main breaker to 150A. (30) EnPhase M250 microinverters. (30) 285W pv modules.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74131	15041-20000-40515	17260 W GRESHAM ST	91325	12	195B133   344	2768016016	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2015 12:00:00 AM	12/29/2015 12:00:00 AM		Permit Finaled	12/31/2015 12:00:00 AM	ADDRESS	34.23029	-118.51077	PV1. Install roof mounted PV system sized 7.3 kW. Interconnected with main service panel.(34) Solar World SW285 Modules(34) Enphase M215 Microinverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74132	17041-30000-43036	124 W 9TH ST	90015	14	127-5A209 247	5139002018	[Q]C2-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	12/07/2017 12:00:00 AM		Issued	12/07/2017 12:00:00 AM	ADDRESS	34.04201	-118.25589	"Plan check for Title 24 only in existing space T.I. retail space. Total area: 1,033 sq ft. Building application number: 17041-30000-34793""COMPLY WITH DEPARTMENT ORDER effective date11/15/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74133	18041-20000-22820	4841 N ALONZO AVE	91316	5	168B129   316	2182005015	RS-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	34.15831	-118.52133	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (16) modules. System is interconnecting with a 400-amp service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74134	15041-20000-26234	10336 N ENCINO AVE	91344	12	204B129   112	2733023035	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.25876	-118.51528	Plan check for PV roof mounted system. System size: 6.8kW with 24 microinverters and 24 modules. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74135	10041-10001-02550	14655 W BLYTHE ST 1-69	91402	6	189B149   325	2210020002	R3-1	North Valley	Mission Hills - Panorama City - North Hills			1200.30	Electrical	Electrical	Apartment			05/25/2011 12:00:00 AM	06/22/2011 12:00:00 AM		Permit Finaled	10/28/2011 12:00:00 AM	ADDRESS	34.21532	-118.45271	Adding new panel and circuits to previously approved set of plans,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74136	18041-10002-05964			11	138B117   338	4431005029	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2019 12:00:00 AM			PC Approved	03/27/2019 12:00:00 AM	PIN	34.07165249	-118.55995275	DELTA 2 CHANGES TO AN APPROVED SET. ADDITION OF 1 EATON DISCONNECT. original scope: ((PC FOR THREE ENERGY STORAGE SYSTEMS (TESLA POWERWALL) 40.5kWh IN A SINGLE FAMILY DWELLING. SCOPE INCLUDES NEW LOAD CENTER (200A) WITH EXISTING PV SYSTEM (PER 702.12(D)(2)(3)(C)) ))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74137	14041-10000-26643	909 W TEMPLE ST	90012	14	133-5A211 268	5161001060	C4-2D, R4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	34.06102	-118.24942	Title 24 plan check only.  Total area = 1100 sq. ft.  New lighting and recepticles for a theater space (Max occupancy = 36) in a mixed use commercial / apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74138	16041-10000-00890	535 W 91ST ST	90044	8	094-5A201  57	6038007041	RD5-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	33.95429	-118.28378	PV1 SFD. THIS IS ADDITION TO EXISTING PV SYSTEM. NEW 3KW INVERTER WITH NEW SUBPANEL. RECONNECT EXISTING SYSTEM. TOTAL OUTPUT 7KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74139	10041-10000-03999	1389 S MIDVALE AVE 8 units	90024	5	132B153   880	4324008009	[Q]R4-1L	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Apartment			03/05/2010 12:00:00 AM	03/22/2010 12:00:00 AM		Permit Finaled	04/04/2011 12:00:00 AM	ADDRESS	34.05504	-118.44304	New fire alarm for an 8-units, 4-stories apartment building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74140	19041-10000-47872	13742 N WHEELER AVE	91342	7	228B153   278	2503022034	RE11-1	North Valley	Sylmar	Sylmar		1060.10	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.32205	-118.43917	NEW ROOF MOUNTED 5.76KW PV SYSTEM WITH 16 PV PANELS (360W) AND OPTIMIZER AND ONE 5KW CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74141	14041-10001-28878	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/09/2015 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	07/25/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	((11-4-2015: CHANGES MADE TO APPROVED SET. ADDED LOADS. ALL CHANGES HAVE BEEN CLOUDED ON DELTA 15))Pc for power and energy. Phase 4 (superstructure) of westfield century city shopping center renovation. Providing new high effecieny led lighting and control lighting on parking level 3-5. Provide power for new hvac and plumbing and elevators, and esclators. Total area 333773 sq ft.Planchecker to reverify the fees and the B apps#  for energy code. B# 13016-10000-16108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74142	17041-10000-24638	6801 W HOLLYWOOD BLVD C5-525	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.10229	-118.33907	RESTAURANT TI ON 5TH FLOOR. PC FOR POWER AND ENERGY. A OCCUPANCY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74143	15041-20000-31727	6301 N OWENSMOUTH AVE 7 FLOOR	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/24/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	02/12/2016 12:00:00 AM	ADDRESS	34.18467	-118.60176	PLANCHECK FOR TITLE 24 ENERGY. FULL FLOOR TI ON 7TH FLOOR (20,306 SF). NEWLY CONNECTED LOAD <400 AMPS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74144	19041-10000-44867	2939 N GLENDOWER AVE	90027	4	153B197   259	5588006022	RE11-1	Central	Hollywood	Los Feliz	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			Verifications in Progress	09/18/2023 12:00:00 AM	PIN	34.11466958	-118.29883158	PC FOR POWER ONLY. NEW 120/208V, 1200 AMP, 3PH 4W TO A SINGLE FAMILY DWELLING. SCOPE OF WORK INCLUDES NEW CIRCUITS AND PANELS. ****************************PLAN CHECKER TO VERIFY FEES****************************_____________________________________________________________________  ***CONSTRUCT NEW 3 STORY SINGLE FAMILY DWELLING OVER 1 LEVEL BASEMENT WITH ATTACHED GARAGE****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74145	12041-10000-15445	500 S VIRGIL AVE	90020	13	135A201    62	5077005021	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Info Complete	07/30/2012 12:00:00 AM	ADDRESS	34.06492	-118.28687	REMODEL SUITE 502 AT THE HOLLYWOOD PRESBYTERIAN MEDICAL CENTER-NEW 800A DISTRIBUTION BOARD TO SUPPLY NEW CIRCUITS TO NURSES'STATIONS EXAM ROOMS AND DOCTORS' OFFICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74146	17041-10000-14333	8900 W VENICE BLVD	90232	5	120B169   508	4312014271	(T)(Q)M1-2D	West Los Angeles	Palms - Mar Vista - Del Rey	South Robertson		2701.00	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	07/21/2021 12:00:00 AM	ADDRESS	34.02908	-118.38822	FULL PC FOR POWER AND ENERGY FOR A 5-STORY MIXED USE BUILDING. RETAIL AND RESTAURANT ON 1ST FLOOR, OFFICE ON THE 2ND THROUGH 5TH LEVELS AND PARKING IN 2 BASEMENT LEVELS. SCOPE INCLUDES ADDING A NEW 5000A SERVICE, NEW PANELS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 350,000 B#16010-10000-05417	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74147	14041-10001-24947	3621 S ROSEWOOD AVE	90066	11	111B149   282	4245011016	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	11/21/2014 12:00:00 AM	ADDRESS	34.00295	-118.44623	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 2.295 KW DC ROOF-MOUNTED SOLAR ARRAY ON A  HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(9) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74148	18041-10000-02109	1400 N SPRING ST	90012	1	136-5A217  83	5409004007	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			01/19/2018 12:00:00 AM			PC Info Complete	01/23/2018 12:00:00 AM	PIN	34.06640655	-118.23243996	PC FOR INTERIOR TI WORK ONLY TO EXISTING OFFICE SPACE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW PANELS, LIGHTS AND CIRCUITS. TOTAL AFFECTED AREA 11140 SQ. FT. PERMIT WAS PULLED AS EXPRESS PERMIT 17041-10000-45764.B# 17016-10000-23682	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74149	13041-20000-03178	400 S HOPE ST ste p2	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.05199	-118.25366	Plan check for energy and emergency lighting. Suite P2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74150	13041-10000-18375	236 S LOS ANGELES ST	90012	14	129A213    65	5161024006	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/11/2013 12:00:00 AM	08/14/2013 12:00:00 AM		Permit Finaled	11/19/2014 12:00:00 AM	ADDRESS	34.04922	-118.24386	New methane gas detection system, Level 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74151	10041-20000-24061	1050 S HILL ST	90015	9	126A209    94	5139013019	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/02/2010 12:00:00 AM	12/30/2010 12:00:00 AM		Permit Finaled	03/14/2011 12:00:00 AM	ADDRESS	34.04038	-118.25933	Plan check T24 Energy (general/emergency) lighting for existing kitchen TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74152	14041-10000-26424	6856 N VALJEAN AVE	91406	6	183B141   649	2224025012	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.03	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.1954	-118.4857	Title 24 plan check only.  Total area = 11,400 sq. ft.  Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74153	14041-20000-07204	22460 W MAYCOTTE ROAD	91364	3	171B101  1152	2075030013	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	07/22/2014 12:00:00 AM	ADDRESS	34.1608	-118.61552	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74154	15041-20001-02780	12473 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Approved	03/10/2015 12:00:00 AM	ADDRESS	33.97916	-118.41034	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74155	16041-10002-30820	621 W ROSECRANS AVE	90248	15	075B201    35	6132006031	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	04/04/2017 12:00:00 AM	ADDRESS	33.90205	-118.28562	11/28/2016 Changes to an approved set of plan. PV 2 roof mounted system. PV 2 feed to 2 existing meters both meters area totalized (1 property owner)an interactive photo voltaic system will be installed on roof. total of 803 modules and 10 inverters. total system size is 310kw AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74156	14041-20000-00357	8901 N DARBY AVE	91325	12	195B125   414	2769003020	R1-1	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2014 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.23212	-118.53406	PV1 CENTRAL INVERTER. SERVICE SIZE 400A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74157	16041-10000-02063	17858 W SIDWELL ST	91344	12	219B129   673	2601071029	RE11-1-H-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	03/03/2016 12:00:00 AM	ADDRESS	34.29981	-118.52366	PV1, Install 5.035 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. (1) INVERTER:  ABB PVI-3.6-OUTD-S-US-Z-A.  (19) Modules: KYOCERA  KU2656ZPA	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74158	14041-20000-02177	9546 N MELVIN AVE	91324	12	201B117   617	2761007028	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.24405	-118.56	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 17.25KW AC USING 2 INVERTERS WITH ISOLATION TRANSFORMER. 3 STRINGS/ INVERTER $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74159	17041-10001-19505	243-249 S MISSION ROAD	90033	14	127-5A217 111	5172014018	M2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			01/11/2018 12:00:00 AM			PC Approved	01/11/2018 12:00:00 AM	ADDRESS	34.04459	-118.22788	Changes to approved set.  changes limited to delat 1 and 2.  Permit is existing under master permit 17041-10000-19505>>>>PLAN CHECK FOR POWER AND ENERGY FOR TI. SCOPE OF WORK INCLUDES NEW PANELS, EQUIPMENT, LIGHTING ON EXISTING DISTRIBUTION EQUIPMENT. CONNECTED LOAD >400A. TOTAL AFFECTED AREA 15094 SQ. FT.<<<<<<	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74160	12041-20000-17924	5251 N LANKERSHIM BLVD	91601	4	171B173   417	2350017033	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			08/01/2012 12:00:00 AM	08/01/2012 12:00:00 AM		Permit Finaled	01/04/2013 12:00:00 AM	ADDRESS	34.16622	-118.37563	energy plan check bob's cafe	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74161	14041-10000-05681	4251 S CHASE AVE	90066	11	108B157   623	4231009025	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	33.99289	-118.4297	PV1, INSTALL 3.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOME, INTERCNNECT WITH MAIN SERVICE PANEL.(14) MODULES: CANADIAN SOLAR CS6P-250PX(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74162	13041-20000-23097	1464 S ROBERTSON BLVD	90035	5	129B169   204	4303001016	C2-1-O	Central	Wilshire	South Robertson		2170.02	Electrical	Electrical	Commercial			08/23/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	02/14/2014 12:00:00 AM	PIN	34.05293772	-118.38363398	"DENTAL OFFICE. HEALTH CARE FACILITY. FULL PLAN CHECK FOR POWER AND ENERGY. NEW SERVICE UPGRADE TO 400A, NEW PANEL ""A"" AND REPLACE ALL EXISTING BREAKERS IN PANEL ""P"" WITH NEW PER PLAN.  NOT OSHPD3 PER ENGINEER."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74163	13041-20000-19949	768 N TERRACE 49	90042	1	153A223   393	5471015023	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.11172	-118.20932	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW USING 12 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74164	18041-10000-47149	13213 W ROSE AVE	90066	11	114B149   484	4244004024	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	01/04/2019 12:00:00 AM		Issued	01/04/2019 12:00:00 AM	ADDRESS	34.00899	-118.45386	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH AC COUPLED BATTERY STORAGE UNIT. (1) 7.6KW INVERTER AND (5KW) TESLA BATTERY. PV MODULES HAVE BEEN APPROVED AND FINALED IN THE PAST. TOTAL SYSTEM SIZE IS 7.6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74165	17041-10000-04453	12705 W BLUFF CREEK DR	90094	11	102B161  1273	4211037029	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			02/10/2017 12:00:00 AM	02/10/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	33.97516	-118.41485	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW 4 STORY, 6 UNITS CONDO  APARTMENT BUILDING. SCOPE INCLUDES 61 FA DEVICES, AND 4 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74166	19041-10000-11536	505 S VERMONT AVE	90020	10	135B197   768	5502024013	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.06509	-118.29191	PC for T24 for an outdoor parking lot. Installing outdoor led fixtures.Plan Check Only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74167	19041-20001-18308	7140 S LA TIJERA BLVD	90045	11	102B173   437	4103009098	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2761.00	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/28/2019 12:00:00 AM	ADDRESS	33.97299	-118.37628	Expedited plan check fee.PV2.  Install 22.44 kW DC / 20.9 kW AC CEC roof mounted grid tied PV system.  (68) modules with (2) 9 kW three phase inverters interconnected with 1200A 208Y/120V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74168	15041-10000-00684	1251 S CRENSHAW BLVD	90019	10	129B185  1001	5082024021	R3-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM			PC Approved	01/09/2015 12:00:00 AM	ADDRESS	34.04843	-118.32656	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Permit pulled online under PCIS #14041-10000-29802.  Plan check at request of inspector.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74169	15041-10000-24658	13129 W GAULT ST	91605	2	183B157   214	2327013014	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2015 12:00:00 AM	07/31/2015 12:00:00 AM		Permit Expired	08/25/2017 12:00:00 AM	ADDRESS	34.19946	-118.41918	PV 1, PC OVER THE COUNTER FOR ROOF TOP MOUNTED SOLAR SYSTEM FOR 7.6KW INVERTER, 29 MODULES AND P300 POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74170	10041-10000-11701	1 S LMU DR	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Public Safety Only			06/18/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	05/18/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	NEW FIRE LIFE SAFETY SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74171	19041-20000-11621	10645 N BOTHWELL ROAD pv1	91311	12	207B117   268	2708013010	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2019 12:00:00 AM	04/01/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.26385	-118.56164	pv1install roof mounted pv system sized 11.4KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74172	16041-20002-37490	1534 W FLORENCE AVE	90047	8	102B193  1368	6018005030	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	Commercial			11/28/2016 12:00:00 AM			PC Approved	11/28/2016 12:00:00 AM	ADDRESS	33.97441	-118.30372	"Revisions to approved set.  Changes made to ampacity correction calculations to justify current wiring design per inspection corrections.  Calculations now properly reflect 8 current-carrying conductors in a single raceway and minimum 1/2"" raceway height above rooftop plane.  (((pv2install roof mounted pv sytem sized 10kw interconnected with msp.)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74173	10041-10000-07108	732 E 10TH ST	90021	9	124-5A211 195	5132011030	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/19/2010 12:00:00 AM	04/19/2010 12:00:00 AM		Permit Finaled	08/03/2010 12:00:00 AM	ADDRESS	34.03504	-118.25099	fIRE ALARM FOR COMMERCIAL BUILDING ONE STORY.  PLAN IS APPROVED BY LAFD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74174	18041-10001-15213	100 WORLD WAY	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/03/2018 12:00:00 AM			PC Approved	08/17/2018 12:00:00 AM	ADDRESS	33.94572	-118.40095	PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE UPDATE LIGHTING PLAN AND TITLE 24 DOCUMENTSPLANCHECK FOR POWER AND ENERGY. CHANGE OF USE AND TI OF SPACES WITHIN T1 ARRIVALS LEVEL TO EXPAND CHECKED BAGGAGE INSPECTION SYSTEM (CBIS) AND CHECKED BAGGAGE RECONCILIATION AREA (CBRA); BUILDING PERMIT # 18016-10000-10246	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74175	17041-30004-41458	1333 S BEVERLY GREEN DR 1-4	90035	5	129B165   130	4330004010	[Q]RD2-1VL-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Apartment			02/12/2019 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.05319	-118.40537	02/12/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Service equipment orientation has changed, service entrance conductors are now encased in concrete, EV charger loads have been relocated, and a subpanel has been removed.02-08-2019 Changes to an approved set of plans, Changes include addition of an EV Charger and sup-panel and relocate load, all changes to has been cluded as delta 1 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74176	14041-10001-14634	12800 W VENTURA BLVD	91604	2	165B161  1067	2384016046	C1.5-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	04/21/2015 12:00:00 AM	ADDRESS	34.14462	-118.41177	CHANGES TO PERMITTED SET OF PLANS: ADDED FEW CIRCUITS TO EXISTING PANELBOARDS; REMOVE PRIVATE OFFICES AND ADDED LIGHTING IN THE SPACE; MOVE LUMINAIRES TO ADJUST TO CHANGESPLAN CHK  ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74177	16041-10001-42227	10250 W SANTA MONICA BLVD	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	08/06/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Change to approved set of plans. Additonal fire alarm devices were added. Adding 171 devices. Changes under delta 3,4.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74178	19041-20001-03947	1040 N LAS PALMAS AVE	90038	4	144B185   802	5532025016	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.09003	-118.33615	04-22-2019 Changes to an approved set of plan, changes include revised drawing to reflect as built plan. All changes has been clouded as delta 2. Plan check only, permit covered under master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74179	15041-10000-25814	12481 W OSPREY LANE 1-3	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/10/2015 12:00:00 AM	08/10/2015 12:00:00 AM		Permit Finaled	09/17/2015 12:00:00 AM	ADDRESS	33.9791	-118.41047	NEW FIRE ALARM SYSTEM FOR NEW 4 STORY BUILDING. SCOPE INCLUDES 37 FIRE ALARM DEVICES, 1 CONTROL PANEL AND 1 FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74180	19041-20001-46675	10400 N KEOKUK AVE	91311	12	204B113    77	2707022015	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			PC Approved	11/16/2019 12:00:00 AM	ADDRESS	34.25901	-118.5739	Expedite per applicant request, Plan check for PV roor mounted system, PV system size: 14.76KW DC, 11.4KW AC with 41 PV modules and 1 inverter(11.4KW) connected to existing 200A MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74181	13041-10000-22938	3572 S INGLEWOOD BLVD	90066	11	114B153   299	4249016022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	08/26/2013 12:00:00 AM		Permit Finaled	10/02/2013 12:00:00 AM	ADDRESS	34.01093	-118.43252	PV1 ROOF MOUNTED SOLAR INSTALLATION USING STANDARD PLAN (GROUNDED/TRANSFORMERED). SYSTEM SIZE IS 11.76 KW DC AND 7.5 KW AC. [MODULES: TRINA SOLAR # TSM-245PC05 |||| INVERTER: IG PLUS V 7.5]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74182	15041-10001-38856	8500 N BALBOA BLVD	91343	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	PIN	34.22443327	-118.49947932	PC TO APPROVED SET. SCOPE INCLUDES CHANGES IN LUMINAIRE RATING AND REDUCTION\CHANGE IN LUMINAIRE COUNT TO REFLECT FIELD INSTALLATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74183	18041-20000-44632	14000 W VENTURA BLVD	91423	4	165B153   530	2266015007	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	Commercial			11/21/2018 12:00:00 AM			PC Approved	12/24/2018 12:00:00 AM	ADDRESS	34.14884	-118.43737	revision to approved set 18041-20000-41591. revision include adding ltg fixtures in the back of the house	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74184	10041-10000-14716	11411 W OHIO AVE BLDG 11	90025	11	129B149   332	4263016028	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			08/11/2010 12:00:00 AM			Corrections Issued	09/28/2010 12:00:00 AM	ADDRESS	34.0471	-118.4526	NEW SERVICE, PANELBOARDS, AND CIRCUITS FOR 22 UNITS APARTMENT BLDG	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74185	16041-10000-09633	380 W WORLD WAY NORT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/18/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	06/02/2016 12:00:00 AM	PIN	33.94094587	-118.40577128	(TI) to a Tenant space AMERICA1, space #T23, LEVEL 4 inside of Tom Bradley Int'l Airport. PC for Energy only, total area: 550 sq.ft (per A.F)Build. #15016-10000-28038	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74186	15041-10000-16356	1017 E WASHINGTON BLVD	90021	14	121-5A211 340	5131003013	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	06/10/2015 12:00:00 AM	ADDRESS	34.02575	-118.2528	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 3100 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74187	16041-10000-45351	780 S MISSION ROAD	90023	14	123A219     6	5171024904	PF-1XL-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			12/27/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.03158	-118.22493	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXTERIOR LIGHTS FOR OUTDOOR PARKING LOT. TOTAL AFFECTED AREA IS 97448 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74188	19041-20001-17739	1071 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   184	5037026025	P-1, [Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	34.01106	-118.29383	SUPPLEMENTAL PLAN CHECK ONLY CHANGE TO APPROVED SET CLOUDED DELTA 1 CHANGES ONLY. CHANGE TO ELECTRICAL POWER PLAN, ADDITION OF A DOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74189	18041-10001-36986	13101 W WELBY WAY	91606	2	180B161   126	2326010008	R1-1	South Valley				1234.00	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM			PC Approved	10/18/2018 12:00:00 AM	ADDRESS	34.19308	-118.41838	**Fee expedited per applicant**Install new PV1, rooftop solar system in (E) SFD. System size at 10.890 kW DC / 10 kW AC. Scope includes: (33) modules with (33) optimizers P400, (1) SE10000 central srting inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74190	19041-10000-24756	4201 S WESTERN AVE	90062	8	114B193   991	5021028028	C2-1VL-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Issued	06/27/2019 12:00:00 AM	ADDRESS	34.00706	-118.30914	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74191	14041-10000-29674	11270 W MAGNOLIA BLVD	91601	2	171B173   666	2353003803	C4-1-CA, R4-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			10/27/2014 12:00:00 AM	12/05/2014 12:00:00 AM		Permit Finaled	06/02/2015 12:00:00 AM	ADDRESS	34.16475	-118.3766	Installation of new 865 device fire alarm system in existing commercial space.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74192	18041-20001-38748	5321 N TOWNSEND AVE	90041	14	165A225    71	5669006041	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Issued	11/08/2018 12:00:00 AM	ADDRESS	34.14532	-118.20141	11-08-2018 Changes to an approved set of plan, changes include PV Modules layout changes, combined 2 strings in load center.  all changes apply to clouded area only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74193	18041-10000-31215	1800 S CENTURY PARK EAST SUITE 450	90067	5	135B161    47	4319001903	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	09/11/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.06244	-118.41523	PC FOR OFFICE T.I. FOR T-24 ENERGY ONLY IN A HIGH RISE. SCOPE INCLUDES NEW  PANEL, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA OF 6036 SQ.FT.B# 18016-10000-25412	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74194	13041-10001-16354	9604 N CREBS AVE	91324	12	201B121   655	2763024010	RS-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM			PC Approved	07/30/2013 12:00:00 AM	ADDRESS	34.24483	-118.54435	(((CHANGES TO APPROVED SET: ADDED JBOX TO TRANS FROM PVWIRE TO THWN-2)))PV1.  Install roof-mounted 10.05 kW DC solar array, interconnect with main service panel.  {41 modules: TSM-245PC05/PA05.18} {2 inverters: Power-One Aurora PVI-3.6-OUTD-S-US-Z}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74195	14041-20000-34854	700 S FLOWER ST SUITE 525	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	04/16/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI TO AN EXISTING COMMERCIAL OFFICE BUILDING.  ADDING LIGHTING AND CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1577.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74196	17041-10000-29227	11005 W BELLAGIO PL	90077	5	141B149   206	4369016014	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.08077	-118.45767	PC for power for new two story single family house. PC for new 800A 120/208V, 3ph, 4W service. Installing new service equipment, panels, circuits and equipment. This is a combo permit and electrical permit fees are under #15010-10000-04320.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74197	16041-20000-25737	304 S BROADWAY 4TH FLOOR	90013	14	130-5A211  97	5149019029	[Q]C4-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.05076	-118.248	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT OF OFFICES. 2362 SQFT. 4TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74198	18041-10002-21087	5335 W ADAMS BLVD	90016	10	123B177   923	5043002010	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.01	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	03/04/2021 12:00:00 AM	ADDRESS	34.03268	-118.3593	"PLAN CHECK FOR CHANGES TO  APPROVED SET, ALL CHANGES ARE CLOUDED UNDER DELTA ""10"". SCOPE OF WORK INCLUDES CHNAGE THE CONFIGURATION OF THE 3,000 AMP  SERVICE IN THE ELECTRICAL ROOM AND UPDATING THE FEEDER LENGHTS, VOLTAGE DROPS & FAULT CURRENT CALCS. (Plan Checker: BH)OIRGINAL SCOPE: ((PLANCHECK FOR POWER AND ENERGY. NEW 3 STORY MIXED USE BUILDING WITH 60 UNIT APT. BUILDING PERMIT #  17010-10000-01522))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74199	18041-10000-13026	1256 W 7TH ST	90017	1	130-5A205 142	5143012029	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM	05/08/2018 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.05216	-118.26774	REPLACING EXISTING LUMINAIRES WITH LED TYPES IN CORRIDORS RESTROOMS AND GARAGE ON 3RD LEVEL THRU TO THE BASEMENT AND OUTSIDE PARKING HARDSCAPE PLAN CHECK IS FOR TITLE 24 AND 2 EA EMERGENCY CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74200	12041-20000-06174	10850 W WILSHIRE BLVD #330	90024	5	132B153   401	4325005019	PB-1-O, [Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			03/19/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	ADDRESS	34.05923	-118.44139	T. I. for dental office, exist. hi-rise bldg., (CHANGE OF USE PORTION (1234SF) OF (E) OFFICE TO (N) DENTAL OFFICE (SUITE #330); CONVERT (8) STANDARD STALLS TO (12) COMPACT STALLS CREATING 565 PKG SPACES REQUIRED & PROVIDED; NON-STRUCTURAL INTERIOR REMODEL; (N) SUSPENDED CEILING)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74201	17041-20001-07435	725 S BIXEL ST bldg b	90017	1	130-5A207 631	5143004012	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			04/20/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Issued	04/20/2017 12:00:00 AM	ADDRESS	34.0501	-118.26506	4/20/2017Plan check for power.  First time tenant.(((ti to an existing commercial space. adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.  total square footage 4720.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74202	19041-20002-13858	11669 W SANTA MONICA BLVD	90025	11	126B149   234	4262002017	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2675.01	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Closed	07/22/2020 12:00:00 AM	ADDRESS	34.04409	-118.45575	Revisions to approved plans.  Additional service connection, reconfiguration of loads.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74203	14041-10000-33717	2029 S CENTURY PARK EAST	90067	5	132B161   700	4319016033	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05956	-118.41375	Energy plan check for high rise office building T.I (stair only from top to ground level)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74204	11041-10001-05678	6201 W IMPERIAL HWY ROOM 124	90045	6	090B165    34	4129028900		West Los Angeles				2780.00	Electrical	Electrical	Public Safety Only			05/13/2011 12:00:00 AM	05/13/2011 12:00:00 AM		Permit Finaled	06/29/2011 12:00:00 AM	ADDRESS	33.93308	-118.39471	INSTALLATION OF 12 new devices on one existing  panel . Not a  high rise bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74205	13041-10000-32068	13557 W VAN NUYS BLVD	91331	7	207B157   976	2619026029	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.26156	-118.42871	REMODELING OF EXISTING OFFICES-NEW PANELS AND CIRCUITS FOR RECEPTACLE AND LIGHTING  LOADS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74206	12041-10000-21475	18651 W GLEDHILL ST	91324	12	198B121   136	2763005018	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.24193	-118.53997	6.37 roof mounted PV for a single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74207	16041-20000-37093	9827 N CANBY AVE	91325	12	201B125   145	2764001007	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	12/28/2016 12:00:00 AM	ADDRESS	34.24922	-118.53468	Plan check for a Pv1 roof-mounted PV system. System size is 10.3 kWac and consists of (41) modules, (41) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74208	16041-10000-00682	1011 W 65TH ST	90044	8	105B197  1395	6014004019	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2374.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	33.98064	-118.2924	PV 1 roof mounted installation to a single family home. Inverter: 5kw (ABB PVI-5000), (20) modules (Sunmodule Pro SW250).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74209	15041-20000-05126	14455 W CARLSBAD ST	91342	7	219B149   786	2507012011	R1-1	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2015 12:00:00 AM	02/20/2015 12:00:00 AM		Permit Expired	03/17/2017 12:00:00 AM	ADDRESS	34.29419	-118.4481	PV1 SFD. TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER SYSTEM. ENPHASE M215. TOTAL OF 16 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74210	12041-20000-20675	9725 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			08/30/2012 12:00:00 AM			PC Approved	08/30/2012 12:00:00 AM	ADDRESS	34.24604	-118.41908	Plan check for power. Replace 400A breaker with 600A breaker. No new load added. Future plan check for TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74211	19041-20001-53519	4153 N NAGLE AVE	91423	4	165B157  1020	2373003007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2019 12:00:00 AM			PC Approved	01/06/2020 12:00:00 AM	ADDRESS	34.14542	-118.4238	PV1. INSTALL 14.52 KW DC ROOFMOUNTED PV SYSTEM WITH (44) MODULES AND MICROINVERTERS(ENPHASE IQ7X-96-2-US)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74212	09041-20001-22257	1016 N SYCAMORE AVE	90038	4	144B181   575	5532030010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			01/27/2010 12:00:00 AM			PC Approved	01/27/2010 12:00:00 AM	ADDRESS	34.0895	-118.34265	Revision to previously approved plan. The change is adding and removing some light fixtures. This plan check is only for title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74213	18041-20000-37694	12632 W SUNSET BLVD	90049	11	132B141   565	4405028017	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.05702	-118.48405	Plan check for energy storage system install in to existing PV System, 2 Powerwall 13.5kWh, Energy Storage System size: 27kWh	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74214	17041-30000-19370	2321 S FOX HILLS DR	90064	5	129B161   222	4315016006	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			06/08/2017 12:00:00 AM	06/08/2017 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.05024	-118.41482	Plan check for a fire alarm system for a 4-story, 8-unit apartment building. System consists of (1) FACP, (1) annunciator, and (58) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74215	10041-20000-11512	1714 W STONE CANYON ROAD	90077	5	150B145   241	4370009012	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			06/16/2010 12:00:00 AM	11/01/2010 12:00:00 AM		Permit Finaled	12/27/2012 12:00:00 AM	ADDRESS	34.10365	-118.45916	Plan check power and energy for single-family dwelling unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74216	18041-20000-45016	24304 S ROSCOE BLVD	91304	12	192B089   201	2017039012	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Issued	11/27/2018 12:00:00 AM	ADDRESS	34.2193	-118.65537	Plan check for roof mounted system, system size: 2.835kW with 9 PV modules and 1 inverter(3.0kw)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74217	14041-20002-03004	7343 N RESEDA BLVD	91335	3	186B125   756	2118015003	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			04/17/2018 12:00:00 AM			PC Approved	04/17/2018 12:00:00 AM	ADDRESS	34.20424	-118.53632	4/17/2018change of contractor. change em lighting in stairways to bug eyes.this is plan check only.  (((New Mix-use - 2,280 sf Retail  & 40 Unit  Apt. Bldg. With 1st and 2nd floor private garage/retail and 3rd/4th/5th/6th floor 40-units Apt. bldg with bonus dencity.  New 1600A service, switchboard, panels, and branch circuit.  Plan check for power and energy.Note: Variance to separate fire alarm is submitted.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74218	15041-10001-10802	555 W REDONDO BEACH BLVD	90248	15	072B201    97	6120028006	C1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	Commercial			06/25/2015 12:00:00 AM	06/25/2015 12:00:00 AM		Permit Expired	07/21/2017 12:00:00 AM	ADDRESS	33.89286	-118.28458	Change to approved set by adding (58) fire alarm devices and power supply on the floor plan.  (((FIRE ALARM FOR 2 STORY(E) BUILDING. 99 FIRE ALARM DECIVES, 1 CONTROL PANEL AND 1 FIRE ALARM PANEL.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74219	19041-20000-37658	13110 W HARTSOOK ST	91423	4	171B161   697	2358004020	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.16384	-118.41845	Plan check for PV roof mounted system, PV system size: 12.54KW DC, 11.68KW AC CEC with 38 PV Moduels and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74220	17041-20002-21308	5950 N LAUREL CANYON BLVD	91607	2	177B165   769	2340005037	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.17861	-118.39631	Revisions to approved set.  Change of # of modules to (192), change of inverter type from microinverter to string inverter, and wiring changes.  (((PV2.  Install 60 kW roof mounted grid tied PV system on an (E) carwash roof.  (200) modules with Enphase C250 microinverters.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74221	19041-10000-38542	755 S LOS ANGELES ST	90014	14	127-5A211 253	5145001013	M2-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	07/22/2021 12:00:00 AM	ADDRESS	34.04231	-118.25201	PC FOR FIRE ALARM FOR A COMMERCIAL AREA. SYSTEM CONSISTS OF (1)FACP AND (426) DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74222	12041-20000-03039	22451 W MIRANDA ST	91367	3	174B101   101	2040039006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2012 12:00:00 AM	05/02/2012 12:00:00 AM		Permit Finaled	06/25/2012 12:00:00 AM	ADDRESS	34.17546	-118.61634	Photovoltaic system on roof of a two story single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74223	15041-10000-13201	777 S ALAMEDA ST Building 1	90021	14	124-5A215  30	5146009004	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	ADDRESS	34.03396	-118.24117	PLAN CHECK FOR MEDIUM VOLTAGE SWITCH GEAR. MAIN DISTRIBUTION IS UNDER 15041-10000-13198	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74224	12041-10001-26019	11922 S VERMONT AVE	90044	15	084B197   351	6088020013	C2-1L	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Commercial			06/03/2013 12:00:00 AM			PC Approved	07/02/2013 12:00:00 AM	ADDRESS	33.92425	-118.29139	sent back to plan check by INSPECTOR: VERIFY CEC certification OF EMCS. ALSO  CONTROL CHANGES (removed overrides from the front of the store because they are integrated into the EMCS. )changes to approved set (12041-20000-26019 - T-24 and emergency lighting plan check for remodeled Ralph's store.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74225	11041-20000-16167	9310 N RESEDA BLVD	91324	12	198B125   196	2764011027	C4-1VL, P-1VL	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM	11/22/2011 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	34.23949	-118.53589	dental office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74226	12041-10005-07640	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	PIN	33.94094587	-118.40577128	AS-BUILT SET OF PLANSPLANS INCLUDE ALL FIELD CHANGES AND UPDATES OF 5-28-15Plan check power for LAX Terminal 5 Primary switchgear and distribution (infracture upgrade). New equipment, switchboards, and panels. Existing service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74227	13041-10000-17401	4980 S CENTINELA AVE 1-12	90066	11	105B161   122	4221021015	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Apartment			07/01/2013 12:00:00 AM	07/01/2013 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	33.98729	-118.41601	New fire alarm system for apartment for 3 story with the addition of a loft. The project consist of 1 panel with 37 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74228	17041-10000-20347	1427 W PACIFIC COAST HWY	90710	15	033B193    36	7410009039	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.04	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	33.78962	-118.30229	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74229	17041-20001-35816	24034 W SCHOENBORN ST	91304	12	192B089   151	2017037019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.22118	-118.65019	EXPEDITED PER APPLICANTS REQUEST.PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.32 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74230	15041-10000-38380	3675 S DUNN DR	90034	5	120B165   742	4313007029	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			11/13/2015 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	34.02542	-118.40178	PC FOR FULL PLAN CHECK FOR A NEW 4-STORY, 18-UNIT , ONE LEVEL GARAGE APARTMENT BUILDING. TOTAL AREA 32593.19 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74231	18041-10000-48457	555 S MATEO ST STE 300	90013	14	126A217    86	5164002012	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/21/2018 12:00:00 AM	01/21/2020 12:00:00 AM		Issued	01/21/2020 12:00:00 AM	ADDRESS	34.03943	-118.23302	FULL PC FOR POWER AND ENERGY FOR AN EXISTING SPACE. SCOPE OF WORK INCLUDE A NEW 300KVA TRANSFORMER, AND 1000A 120/208V DISTRBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74232	14041-20000-08590	16852 W SAN FERNANDO MISSION BLVD	91344	12	210B133   996	2683028036	C2-1L, P-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	34.2711	-118.49968	Install new general/emergency lighting.  Plan check for energy only.Note:  Permit is under 14041-20000-05898	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74233	14041-10000-12991	669 S UNION AVE	90017	1	132A205   269	5142012004	R5P-2	Central	Westlake	Westlake South		2089.02	Electrical	Electrical	Apartment			05/15/2014 12:00:00 AM			PC Approved	05/15/2014 12:00:00 AM	ADDRESS	34.05484	-118.27074	permit to be pulled at EPC counter only. Plan check for energy only. TI (E) laundry room of apartment building. emergency lighting installed. not high rise per applicant. pc only, permit issued separately.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74234	18041-10000-24130	21200 W VENTURA BLVD	91364	3	171B105   172	2167002038	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.16713	-118.59486	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74235	14041-20000-32670	515 S FIGUEROA ST SUITE 1105	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05199	-118.25764	TI TO AN EXISTING HIGH RISE OFFICE BUILDING.  ADDING LIGHTING FIXTURES TO EXISING PANELS.  PLAN CHECK FOR ENERGY TITLE 24.  WORK TO BE PERFORMED IN SUITE 1105. TOTAL SQUARE FOOTAGE 3372.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74236	17041-10000-28502	7415 S LA TIJERA BLVD	90045	11	099B169   154	4104017043	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			08/11/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	33.97033	-118.38003	PC FOR FA  FOR AN 4 STORY APARTMENT BUILDING  WITH 3 UNDERGROUND PARKING LEVELS.SCOPE INCLUDES 367 DEVICES AND 8 PANELS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74237	15041-20000-29409	18737 W VENTURA BLVD	91356	3	174B121   517	2160002050	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	09/08/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.1713	-118.54183	CHANGE OF USE FROM RETAIL TO NEW MUSIC STUDIO WITH NON STRUCTURAL T.I., NO SCHOOL, NO STUDENT. INSPECTOR TO VERIFY INSTALLED FIXTURE WATTAGE.pc for title 24 energy only. new lighitng for music rooms. no other lighitng changes per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74238	09041-10007-08059	6250 W HOLLYWOOD BLVD	90028	13	148-5A189 132	5546029917	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/22/2010 12:00:00 AM	01/22/2010 12:00:00 AM		Permit Finaled	04/06/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	1-22-10 - Revisions made to panel schedules K2, L11HS2, L11HS3.  Permit is for new water heater, ice machine, and new AC-1.  P/C is for Power only  :: Revise the panels schedules and add circits, equipment, and exit signs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74239	16041-10000-18367	4048 N BECK AVE	91604	2	162B169   390	2368023052	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.14125	-118.38312	*Permit Fee $0 due per CA Senate Bill 1222.PV1 plan check for new solar system. AC system size 16 kW. 48 Canadian Solar modules. 2 SMA SB8000TL-US inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74240	17041-10007-37515	1400 N CAHUENGA BLVD	90028	13	147A187   280	5546014052	C4-2D	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM	03/16/2021 12:00:00 AM		Permit Finaled	01/31/2022 12:00:00 AM	ADDRESS	34.09641	-118.32933	Delta 16 changes to an approved set. New circuits for hotel signs, new condensing unit for kitchen use and updated loads on the panel schedule. Changes also include decreasing the EV charging power to upsize the kitchen loads. No changes to lighting or T-24______________________________________________FULL PC FOR POWER AND ENERGY. NEW 8 STORY HOTEL WITH RESTAURANT AT GROUND FLOOR (CORE&SHELL ONLY) AND TOP LEVEL AMENITY WITH THREE SUBTERRANEAN GARAGE BASEMENTS.  SCOPE INCLUDES A NEW 2500A 120/208 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 27,500 SQ. FT. B#16010-10000-05898	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74241	17041-10000-31203	5151 N VAN NUYS BLVD	91403	4	171A151    67	2263034013	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.16415	-118.44889	PC for T24 for outdoor lighting consisting of replacing existingfixtures with LED fixtures. Total area 11450sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74242	17041-10001-01229	835 E IMPERIAL HWY	90059	15	087A209   367	6072013022	RD2-1	South Los Angeles	Southeast Los Angeles			2409.00	Electrical	Electrical	Commercial			01/13/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	33.93118	-118.25968	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<NEW ROOF MOUNTED SOLAR SYSTEM ON EXISTING COMMERCIAL BUILDING. TOTAL SYSTEM SIZE = 12.2KVA INCLUDING 2 CENTRAL INVERTERS(SOLIVIA - SOLIVIA 5.2TL & 7.6TL), WITH 50 MODULES(LDK 280P-24).>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74243	14041-20000-11240	700 S FLOWER ST suite 2600	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	05/08/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.04835	-118.25882	TI - ENERGY PLAN CHECKExisting high rise building, 26th floor tenant remodel (11,570 sqft).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74244	19041-10000-53304	4139 N SUNNYSLOPE AVE	91423	4	165B157  1009	2373010006	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2019 12:00:00 AM	12/31/2019 12:00:00 AM		Issued	12/31/2019 12:00:00 AM	ADDRESS	34.14563	-118.42729	PER AB# 1414 & SB#12222 $0.00 FEES[EPLAN] CHANGES ON APPROVED SET. RELOCATION OF ELECTRICAL EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74245	14041-10000-03317	7800 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Closed	02/19/2014 12:00:00 AM	ADDRESS	33.93845	-118.42964	PLAN CEHCK FOR TEMPORARY  batch plant , PLAN CHECK FOR SERVICE/BOARD  FEEDING Batch Plant 13041-10000-32206. BATCH PLant  INSTALLED FOR PERIOD OF TIME ( 6 MONTHS TO 1 YEAR).  BATCH PLANT TO BE HANDEL UNDER SPECIAL EQUIPMENT INSP3ECTION PER INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74246	17041-20000-11040	6106 N LANKERSHIM BLVD	91606	2	177B169   518	2338005008	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.05	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.18158	-118.38448	ti to an existing commercial space.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74247	19041-20000-06113	5670 W WILSHIRE BLVD STE 1350	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/20/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	T24 PLAN CHECK FOR EXISTING HIGH RISE COMMERCIAL BUILDING,STE 1350, LIGHTING ONLY Y. TOTAL SQUARE FOOTAGE = 475 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74248	18041-20001-08676	7600 N BALBOA BLVD 201	91406	6	186B133   186	2205008021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/19/2018 12:00:00 AM	03/19/2018 12:00:00 AM		Issued	03/19/2018 12:00:00 AM	ADDRESS	34.2087	-118.50093	SUPPLEMENTAL PLANCHECK FOR POWER DUE TO FIRST TIME TENANT  AND CHANGES TO T24 ENERGY.  MASSAGE PARLOR.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74249	14041-10000-09943	11620 W WILSHIRE BLVD # 410	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			04/15/2014 12:00:00 AM			PC Approved	04/15/2014 12:00:00 AM	ADDRESS	34.05021	-118.45963	TENANT IMPROVEMENT IN OFFICES OF A SINGLE STORY BUILDINGPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74250	14041-10000-23275	1645 W 36TH PL	90018	8	120B193  1316	5041015006	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			08/26/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Expired	09/28/2016 12:00:00 AM	ADDRESS	34.02214	-118.30735	PV1 4.59KWdc. 240V. xmfrLESS/Ungnd. STD. 1story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(18)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74251	19041-20000-24024	5155 N KELVIN AVE	91364	3	171B109   190	2166031006	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	11/01/2019 12:00:00 AM	ADDRESS	34.16413	-118.58497	Installation of 40.5 kWh energy storage system and associated distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74252	16041-20000-28394	2859 W FRANCIS AVE 1-81	90005	1	132B197   554	5077022020	R4-2	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Apartment			08/10/2016 12:00:00 AM			PC Info Complete	01/31/2017 12:00:00 AM	ADDRESS	34.05692	-118.28826	Plan check for power and energy. Project site is a new 7-story, 81-unit apartment building. Service size is 2,500-amps and total lighting area = 91,642 sq. ft.Note: Building application has been created under 15010-10000-01186	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74253	19041-10000-41861	10201 W PICO BLVD BLDG 29	90064	5	129B161  1442	4315019013		West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/15/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	07/06/2020 12:00:00 AM	ADDRESS	34.04994	-118.41129	PC FOR ENERGY ONLY, SCOPE OF WORK IS A TI. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 985 SFQT. B# 19016-30000-27981	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74254	14041-20000-24778	12136 W MARSHALL ST	90230	11	108B161   714	4221017029	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	33.99028	-118.41618	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MSP.(17) CANADIAN SOLAR -250P(1) SOLAR EDGE INVERTER WITH POWER OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74255	18041-10000-10575	1715 N VERMONT AVE 1st floor	90027	4	147B197   172	5589028041	C4-1D	Central	Hollywood	Los Feliz		1892.01	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.1023	-118.29205	PLAN CHECK FOR T24 ONLY, TI AT FIRST FLOOR AND REPLACEMENT OF ATMS AT EXTERIOR FOR EXISTING BANK. NEW LIGHTING AND POWER WITH FEW NEW CIRCUITS USING EXISTING PANELBOARDS. TOTAL AREA: 7,104 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74256	16041-10000-26131	2481 N LILLYVALE AVE Build. 408	90032	14	139-5A237  87	5220034026	PF-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			07/25/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.0765	-118.16477	Plan check for Power and Energy.  TI on (E) warehouse and  office building (29,648 SQ FT). Install new electrical equipments, total new load > 400A.( B# 15016-10000-28418)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74257	18041-20001-29316	17415 W MAYERLING ST	91344	12	213B129    80	2601041062	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM			PC Approved	08/28/2018 12:00:00 AM	ADDRESS	34.28323	-118.51367	Expedite per applicant requestPlan check for PV roof mounted system, sysem size: 18.0kW with 50 pv AC modules	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74258	12041-10000-25221	12528 W ALBERS ST	91607	5	174B161   681	2346011004	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1244.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	02/26/2013 12:00:00 AM	ADDRESS	34.17021	-118.40634	New 3.36 kw roof mounted PV for a single family.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74259	18041-20000-06681	7950 N HASKELL AVE	91406	6	189B141    93	2206001019	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			02/23/2018 12:00:00 AM	02/23/2018 12:00:00 AM		Permit Finaled	08/02/2018 12:00:00 AM	ADDRESS	34.21517	-118.47476	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74260	14041-20000-00923	15834 W SEPTO ST PV1	91343	12	201B141   123	2669025012	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/22/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.25091	-118.4774	INSTALL ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74261	15041-20000-36538	6171 W CENTURY BLVD Ground Fl	90045	11	090B165    12	4124030035	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	12/18/2015 12:00:00 AM	ADDRESS	33.9457	-118.39324	Plan check for Title 24 T.I. in existing space. Total area: 7,938 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74262	16041-20000-05583	2137 S DUXBURY CIR	90034	5	126B165   147	4309009022	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.04401	-118.39622	"""0$ permit fees due to senate bill 1222""PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL( HOUSE)  AND MICROINVERTER ( GARAGE)  SYSTEM. SYSTEM SIZE: 16.8 KW2  FRONIUS 6.0 CENTRAL INVERTER4 ENPHASE M250 MICROINVERTER ( GARAGE - 4 MODULES)"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74263	19041-20001-29758	6363 W WILSHIRE BLVD ste 520	90048	5	135B173   823	5510028009	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	34.06385	-118.3674	SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE FROM INVERTER TO BATTERY BACK UP FOR EGRESS LIGHTING, REMOVAL OF PHOTOSENSORS, CHANGE TO LIGHT CONTROLS ON T24 SHEET, CHANGES MADE TO SPECIFIC NOTES, AND CHANGE TO SINGLE LINE DIAGRAM ADDITION OF NEW PANEL AND LOADS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74264	12041-20000-09325	8930 N VILLAGE AVE	91352	2	195B177   265	2404001006	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District, Sun Valley	YES	1021.01, 1021.02	Electrical	Electrical	Commercial			04/24/2012 12:00:00 AM	04/24/2012 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.23076	-118.35614	fire alarm	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74265	15041-10000-30039	8521 N FALLBROOK AVE STE-340	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Permit Finaled	11/19/2015 12:00:00 AM	ADDRESS	34.22368	-118.62797	Energy plan check for an office T.I. located in the 3rd floor of a commercial building. Scope includes new light, equipment, and receptacles; Total area is 17,535-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74266	16041-20001-30540	150 S GARDNER ST	90036	5	138B181  1106	5512009012	R1-1-HPOZ	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2016 12:00:00 AM			PC Approved	10/05/2016 12:00:00 AM	ADDRESS	34.07206	-118.35307	10.5.2016 - Plan check per inspector correction notice. AC disconnect not within site of inverter - AC disconnect must be lockable - Update site plan and single line to show this. Clouded changes only.---solar system approved under permit application #16041-90000-30424======CORRECTION OF ADDRESS FROM 150 N GARDNER ST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74267	18041-20000-12271	200 S LOS ANGELES ST	90012	14	129A213    65	5161024040	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.05007	-118.2433	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT CHANGE USE FROM (E) RETAIL TO PILATES STUDIO. 1915 SQFT. BLDG ABUILDING PERMIT # 18016-10000-10085	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74268	11041-10000-18151	1607 S PACIFIC AVE	90291	11	106-5A143  28	4226009022	C2-1-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			08/25/2011 12:00:00 AM	09/13/2011 12:00:00 AM		Permit Finaled	05/18/2012 12:00:00 AM	ADDRESS	33.98735	-118.47224	CHANGE OF USE FROM RETAIL TO RESTAURANT.  PLAN CHECK IS FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74269	18041-20001-45119	19241 W WELLS DR	91356	3	171B117   348	2163008006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM			PC Approved	12/19/2018 12:00:00 AM	ADDRESS	34.16382	-118.55276	Expedite per applicant requestPlan check for PV roof mounted system, system size: 24.48kW AC, 22.27kW AC CEC with 68 PV Modules and 68 microinverters connected to 400 Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74270	19041-10000-09639	363 E 2ND ST	90012	14	129A215   378	5161017***	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/18/2019 12:00:00 AM			PC Approved	03/18/2019 12:00:00 AM	ADDRESS	34.04833	-118.24002	PLAN CHECK FOR TITLE 24 TENANT IMPROVEMENT REMODEL  EXISTING RETAIL SPACE. TOTAL 2465 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74271	13041-20000-12984	13385 W ELSIE LN	91342	7	225B157  1033	2510019073	(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2013 12:00:00 AM	05/21/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	PIN	34.31283768	-118.42552268	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 1.7KW USING 8 PANELS. USING ENPHASE MICROINVERTER M215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74272	17041-20000-20408	8632 N VAN NUYS BLVD	91402	6	195B149   692	2638001056	[Q]C2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			06/16/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	01/05/2018 12:00:00 AM	ADDRESS	34.22698	-118.44968	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74273	15041-20003-17238	14859 W BESSEMER ST	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.18089	-118.45722	08-27-2015 Change to approved set of plans. Changes include addition of receptacles and lighting fixture manufacturer. Changes apply to delta 1 only. . {{{{{{07-27-2015 Plan check for lost original set of plans, Title 24 only. [[[[[Plan check for Title 24 only retail space. Total area:1450 SF]]]]]]]}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74274	18041-20001-44434	9712 W HEATHER ROAD	90210	4	147B161    16	4352002039	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.01	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.10286	-118.40782	EXPEDITE PER CUSTOMER REQUESTPV1.  Install 24.705 kW roof mounted grid tied PV system.  (81) modules with (2) 7.6 and (1) 5.2 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74275	18041-10000-05060	9801 S ALAMEDA ST MAJOR 3	90002	15	093A217   277	6046019910	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		5354.00	Electrical	Electrical	Commercial			02/12/2018 12:00:00 AM	09/24/2018 12:00:00 AM		Permit Finaled	01/31/2020 12:00:00 AM	ADDRESS	33.94794	-118.22929	PC FOR POWER ONLY, NEW CORE AND SHELL 1-STORY RETAIL BLDG. SCOPE OF WORK INCLUDES NEW 600AMP SERVICE, 208/120V. T-24 PLAN CHECK WILL BE UNDER A SEPARATE APPLICATION. (JORDAN DOWNS PHASE 1C, MAJOR 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74276	17041-20000-41439	13325 W MOORPARK ST	91423	4	165B157   295	2360013024	[Q]C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	11/30/2017 12:00:00 AM	ADDRESS	34.1505	-118.42338	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74277	14041-10001-33281	800 W OLYMPIC BLVD a120	90015	9	127-5A205 519	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM			PC Approved	02/19/2015 12:00:00 AM	ADDRESS	34.04484	-118.26453	Changes to approved set.  New lighting layout.*****Previous work description*****TI for remodeling of restaurant - scope of work is lighting only per applicant.  Plan check for energy.  Emergency lighting existing to remain per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74278	11041-10000-06133	139 N WESTERN AVE BLDG A	90004	4	138B193   868	5517003002	C2-1	Central	Wilshire			2115.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	04/26/2011 12:00:00 AM		Permit Finaled	04/04/2012 12:00:00 AM	ADDRESS	34.0741	-118.3095	"ORIGINALLY , A SERVICE EXISTED TO SUPPLY BUILDING  ""B"" ; SERVICE IS UPGRADED TO SUPPLY BUILDING B AND AN EXISTING BUILDING CONVERTED TO COMMERCIAL USE. TENANT SPACE # 106 WILL BE A RESTAURANT WITH A 2ND FL EXTENDED ABOVE TENANT SPACE # 107 THERE ARE 6 MORE TENANT SPACES IN BUILDING A- TENANT 201 ABOVE TENANT 101"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74279	14041-20000-02953	9019 W 24TH ST	90034	5	126B169   926	4302011022	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	34.03993	-118.38875	pv1 single family dwelling. total system size 5kw ac using transformerless inverter nonstandard plan. 2 strings	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74280	13041-10000-33316	3719 S BUTLER AVE	90066	11	114B157   346	4234010006	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.01108	-118.42363	PV1, ROOF-MOUNTED SOLAR INSTALLATION OF AN 6.3 kW GRID TIED SYSTEM , INTERCONNECTING WITH (E) 200A MAIN. WITH (21) MODULES LG-300N1C-G3, 300W, (21) SOLAREDGE OPTIMIZERS OP300-MV, (1) SOLAREDGE INVERTER SE6000A-US-240V.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74281	16041-20002-44593	7324 N OWENSMOUTH AVE	91303	3	186B105   769	2111014008	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.22	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM			PC Approved	02/23/2017 12:00:00 AM	ADDRESS	34.20358	-118.60141	2.23.2017 - Plan check for modifications to approved set. Relocate two pv modules and associated microinverters from detached garage to main house ONLY. ========PV1.  Install 3.5 kW roof mounted, grid tied PV system on SFD main house and detached garage.  (11) modules with Enphase M250 microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74282	18041-10000-12136	5325 S 8TH AVE	90043	8	108B189   408	5006018006	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	33.99427	-118.32594	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2.1 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74283	16041-10000-36832	13373 W DEL SUR ST	91340	7	213B157   291	2524019018	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	01/11/2017 12:00:00 AM	ADDRESS	34.28146	-118.42486	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(11)MODULES-AXITEC AXIPOWER AC-265P(1)INVERTER-FRONIUS GALVO 3.0	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74284	15041-20000-13720	125 S BARRINGTON PL	90049	11	135B145   464	4402008010	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			05/06/2015 12:00:00 AM	05/29/2015 12:00:00 AM		Permit Finaled	10/01/2016 12:00:00 AM	ADDRESS	34.06649	-118.4694	Plan check for Title 24 only. TENANT IMPROVEMENT OF EXISTING TWO STORY OFFICE BUILDING WITH INCIDENTAL BASEM. STORAGE, DOOR/WINDOW REPLACEMENT & EXTERIOR IMPROVEMENTS. Total indoor area: 9,870 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74285	13041-10000-15109	20307 W WYNFREED LANE	91326	12	216B113   267	2701048054	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	10/01/2013 12:00:00 AM	ADDRESS	34.2918	-118.57551	PV1 ROOF MOUNTED SOLAR INSTALLATION. SYSTEM SIZE IS 10.05 KW, 41 TOTAL MODULES WITH POWER OPTIMIZERS. [MODULES: TRINA SOLAR # TSM-245PC05/PA05.18 |||| INVERTERS: SOLAREDGE # SE3800A-US AND SOLAREDGE # SE6000A-US]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74286	15041-10000-17979	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	10/15/2015 12:00:00 AM		Issued	10/15/2015 12:00:00 AM	ADDRESS	33.79173	-118.23549	ADDING A 480V 600A SECTIONEXTENSION  TO AN EXISTING SWITCHRACK LOCATED IN CLASS 1 DIV 2 LOCATIONS; NO NEW LOADS AS OF TODAY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74287	19041-20000-48511	2261 N KENILWORTH AVE	90039	4	148-5A205 291	5432021001	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Permit Expired	05/16/2024 12:00:00 AM	ADDRESS	34.10078	-118.26742	Plan check for PV system, system size 4.20KW, 12 Modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74288	13041-20000-35788	619 S BIXEL ST	90017	1	130-5A207  21	5143024011	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	02/25/2014 12:00:00 AM		Permit Closed	05/23/2014 12:00:00 AM	ADDRESS	34.05345	-118.26271	New 800 amp Temporary Power.  All loads are future to be installed on a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74289	17041-20000-31514	3321 N BEVERLY RANCH ROAD	90210	4	159B157   162	2386004013	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM	12/08/2020 12:00:00 AM		Permit Finaled	01/05/2021 12:00:00 AM	ADDRESS	34.13254	-118.42877	Plan check for power only. Project site is a new 2-story single-family dwelling. Work includes a 600-amp service with a back-up generator. Permit for 600Amp service, sections and generator. Note: Building permit has been issued under 10010-10000-01260 (Combo Permit)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74290	16041-20001-13422	12886 W KAMLOOPS ST	91331	7	204B161   559	2623026021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2016 12:00:00 AM			PC Approved	05/24/2016 12:00:00 AM	ADDRESS	34.25395	-118.4132	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.Existing solar array on roof. New system is 3.8kW, ungrounded. (15) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74291	19041-20000-04854	3921 W SUNSET BLVD	90029	13	145-5A203 330	5429013002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	02/11/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.09235	-118.27998	Plan check for Fire alarm system, Total fire alarm devices: 49 and FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74292	19041-20000-25866	5901 W CENTURY BLVD	90045	11	090B169    15	4124030042	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	07/31/2020 12:00:00 AM	ADDRESS	33.94572	-118.38685	T24 PLAN CHECK FOR 14 TYPICAL FLOORS OF A EXISTING HIGH RISE BUILDING. LIGHTS ONLY. TOTAL SQUARE FOOTAGE =  28,672 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74293	15041-10000-19889	1200 S FIGUEROA ST	90015	14	126A207   313	5138015027	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/24/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Closed	07/17/2018 12:00:00 AM	ADDRESS	34.04166	-118.26677	temp power to construction site. (2) two thousand amp services. plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74294	11041-10000-15498	6348 W FOOTHILL BLVD	91042	2	198B205   113	2572009018	(Q)C2-1L	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1013.00	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	03/01/2012 12:00:00 AM	ADDRESS	34.2423	-118.26963	NEW GROCERY STORE IN AN EXISTING EMPTY BUILDING.  PLAN CHECK IS FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74295	15041-20000-01985	12024 W SARAH ST	91607	2	168B165   950	2364001037	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	01/22/2015 12:00:00 AM		Permit Finaled	04/06/2015 12:00:00 AM	ADDRESS	34.15388	-118.39507	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(9) SUNIVA OPT270 MODULES(1) ABB PVI-3.0 INVERTERRELOCATING LOADS FROMON MAIN PANEL THROUGH SUB PANEL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74296	18041-10001-23424	5220 W CENTINELA AVE	90045	11	102B173    95	4103002016	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM			PC Approved	03/04/2019 12:00:00 AM	ADDRESS	33.97718	-118.37106	CHANGES TO AN APPROVED SET OF PLANS. CHANGES INCLUDE THE ADDITION OF OUTDOOR FIXTURES. Noted under delta 7.__________________Energy plan check for a restaurant T.I. Scope includes new lighting and equipment with a total Title-24 area cover 1,894-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74297	12041-20003-13751	5450 S LINCOLN BLVD	90094	11	102B157   293	4211022004	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM			PC Approved	02/15/2013 12:00:00 AM	ADDRESS	33.97348	-118.43093	Modifications to previously approved set of plans.  Install conduit only for future X-Ray machine, change the AIC rating of the circuit breakers that supply the ATS switch at panel A and at the generator to 65000 amperes, and show the feeder to panel C as existing.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74298	16041-20000-37197	945 S HUDSON AVE	90019	4	132B185   486	5090006009	R1-1	Central	Wilshire	Greater Wilshire		2161.00	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.05779	-118.33477	Plan check for a PV1 roof-mounted PV system. System size is 10.1 kWac and consists of (30) AC modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74299	18041-10000-39416	15825 W SATICOY ST	91406	6	186B141    52	2206010013	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.20857	-118.4779	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74300	19041-10000-50190	150 W 12TH ST	90015	14	126A207   234	5139025028	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	12/18/2019 12:00:00 AM		Permit Finaled	01/14/2021 12:00:00 AM	ADDRESS	34.03831	-118.26077	PC FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING, CONTROLS, WITH EXISTING CIRCUITS. NOTE THAT THIS TI ONLY COVERS CERTAIN STAIR LIGHTING. TOTAL AFFECTED AREA IS 668 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74301	13041-10000-33057	6230 N SEPULVEDA BLVD	91411	6	177B145   241	2242010024	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			11/25/2013 12:00:00 AM	11/27/2013 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.18388	-118.46592	PC FOR T24 ENERGY ONLY. OUTDOOR LIGHTING FOR COMMERCIAL BUILDING. POLE LIGHTS FOR PARKING AND STORAGE AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74302	11041-10000-02850	21842 W VENTURA BLVD	91364	3	171B105    30	2168026080	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	Commercial			02/14/2011 12:00:00 AM	05/11/2011 12:00:00 AM		Permit Finaled	06/28/2011 12:00:00 AM	ADDRESS	34.16823	-118.60347	Change of use from retail to restaurant. EPC is for power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74303	17041-10000-12681	600 S COMMONWEALTH AVE	90005	10	135A201   145	5077006011	C4-2	Central	Wilshire	MacArthur Park, Wilshire Center - Koreatown		2111.20	Electrical	Electrical	Commercial			04/19/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	03/15/2018 12:00:00 AM	ADDRESS	34.06348	-118.28545	PC FOR POWER. REPLACEMENT OF A 125KVA GENERATOR WITH 300KVA GEN CONNECTING TO EXISTING  600 A& 1600A SWITCHGEAR, REPLACEMENT OF A  150 KVA TRANSFORMER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74304	16041-10000-00270	600 WORLD WAY Terminal 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Closed	03/15/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	Install starbuck sign lighting inside Terminal 6 of LAWA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74305	11041-10000-08624	189 S THE GROVE DR Ste H80	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/05/2011 12:00:00 AM			PC Info Complete	08/11/2011 12:00:00 AM	ADDRESS	34.07125	-118.35662	PER CUSTOMER REQUEST:  FULL PLAN CHECK.  NEW ATHLETA RETAIL STORE GOING IN TO PART EXISTING GAP RETAIL SPACE.  WANTS THIS PLAN CHECK TO BE ACCOMPANIED BY PLAN CHECK FOR GAP (PCIS# 110041-10000-08633) PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74306	16041-10000-10973	9007 N WOODMAN AVE	91331	6	195B153   291	2639033006	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Info Complete	04/19/2016 12:00:00 AM	ADDRESS	34.23306	-118.43913	T-24, PC FOR ENERGY ONLY. TI AN EXISTING RETAIL STORE. TI FOR LEASE TO A SPRINT STORE. SCOPE INCLUDES NEW LIGHTS, NEW RECEPTACLES, AND RELOCATE ELECTRICAL PANEL. TOTAL AFFECTED AREA IS 1036 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74307	19041-20001-37129	4810 N WOODLEY AVE	91436	5	168B141   412	2261022011	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM			PC Approved	10/04/2019 12:00:00 AM	ADDRESS	34.15776	-118.48346	Expedited plan check fee.PV1.  Install 15.04 kW DC / 12.784 kW AC roof mounted grid tied PV system.  (47) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74308	14041-20000-20274	12180 N BOWMORE AVE	91326	12	219B121   283	2820007015	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			07/28/2014 12:00:00 AM	07/29/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.29411	-118.5465	PV1.  Install 7.14 kW roof-mounted, utility-interactive PV system.  (28) Trina Solar TSM-255p ,Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74309	19041-20000-17601	5963 W FOUNTAIN AVE	90028	13	144B189    92	5545014027	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2019 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.09453	-118.3195	PLAN CHECK FOR NEW 600A SERVICE FOR 6 NEW INDIVIDUAL DETACHED TOWNHOUSES. INDIVIDUAL TOWNHOUSE ELECTRICALS PERMITED UNDER SEPERATE BUILDING PERMIT/ADDRESS.B#17010-20000-04756	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74310	13041-10001-36293	3521 S MOORE ST	90066	11	114B153  1113	4245007019	R1-1-HPOZ	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/12/2014 12:00:00 AM	ADDRESS	34.00608	-118.44499	Expedited RSES plan check per applicant request.{{PV1, Install 11 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (2)Transformerless inverter(s): Solaredge SE 5000A-US and Solaredge SE 6000-US. (44) Modules: Trina Solar TSM-250PA05.18.(44) Optimizers: Solaredge OP250-LV-MC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74311	15041-20000-08090	410 W 8TH ST	90014	14	127-5A209  75	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM	02/24/2016 12:00:00 AM		Permit Expired	03/26/2018 12:00:00 AM	ADDRESS	34.04466	-118.25638	Plan check for power and Title-24 (energy).  Total area = 2,286 sq. ft.T.I. to new restaraunt.  Two new 225 A panels connected to existing service.  Lighting and recepticles. emergency lighting thorugh generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74312	16041-10000-30949	916 N WESTERN AVE	90029	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			09/13/2016 12:00:00 AM	11/14/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.08674	-118.30896	Plan check for Medical office. Change of Use from office and Medical office. Total area: 1,625  sq ft.  Building applicantion # 16016-40000-09664	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74313	13041-20000-09636	5249 N LANKERSHIM BLVD	91601	2	171B173   417	2350017033	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.1662	-118.37562	"Change of use from retail to restaurant.  Load is less than 200 amps and occupancy load is 40.  PLAN CHECK ONLY for Energy, with Emergency lighting.  ""COMPLY WITH DEPARTMENT ORDER effective date07/13/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74314	12041-20000-05901	1880 CENTURY PARK EAST S.608	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM	03/14/2012 12:00:00 AM		Permit Finaled	04/24/2012 12:00:00 AM	PIN	34.06321806	-118.4136341	Plan check T24 Energy/Emergency for  S.698Fire/ Life safety existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74315	16041-20000-31191	21234 W MULHOLLAND DR	91364	3	162B105    86	2173018006	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2016 12:00:00 AM	09/13/2016 12:00:00 AM		Permit Finaled	10/25/2016 12:00:00 AM	ADDRESS	34.143	-118.59558	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74316	19041-10000-09362	200 N FALCON ST	90744	15	021B205    24	7440019908	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			03/15/2019 12:00:00 AM	07/12/2022 12:00:00 AM		Permit Finaled	09/19/2023 12:00:00 AM	ADDRESS	33.75579	-118.2664	PC FOR L.A PORT, SCOPE INCLUDES INSTALLING LIGHTINGS AND 2 MOTORS IN A HAZARDOUS LOCATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74317	19041-10000-20995	10545 W BURBANK BLVD	91601	2	174B177   544	2415025001	C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1243.00	Electrical	Electrical	Commercial			06/03/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.1723	-118.36085	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74318	13041-10000-17711	11024 W MAGNOLIA BLVD	91601	2	171B173   669	2353006025	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			Corrections Issued	07/05/2013 12:00:00 AM	ADDRESS	34.16475	-118.37147	TI for restaurant occupying single-story building.  Changes to lighting system and new outlets.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74319	17041-20000-19517	9460 N WISH AVE	91325	12	198B133    51	2692010048	RE15-1	North Valley	Northridge	Northridge East	Yes	1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	10/27/2017 12:00:00 AM	ADDRESS	34.24263	-118.50826	Plan check for a PV1 ground-mounted PV system. System size is 18 kWac and consists of (60) modules, (30) micro-inverters, and (1) load center. Note: Building application has been generated under 17020-20000-01714	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74320	13041-10000-03750	8124 S RAMSGATE AVE	90045	11	099B169  1108	4105023007	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/13/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	33.96472	-118.3828	PV1 MICRO INVERTER two STORY HOUSE. [MIRCRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74321	14041-10001-14154	5520 W SAN VICENTE BLVD	90019	10	129B177    40	5085017001	C2-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	Commercial			11/13/2014 12:00:00 AM			PC Approved	11/13/2014 12:00:00 AM	ADDRESS	34.05373	-118.3547	DELTA 6 REVISIONS TO PERMITTED SET OF PLANS; INCLUDE RELOCATING PANELBOARDS WITH PANEL PA1 RELOCATED ON THE OPPOSITE SIDE OF WALL FROM MAIN SWBD.FOR PANEL PA1, THE FEEDER MCB AND THE MCB OF PA1 SHALL HAVE SERIES RATING EQUAL OR GREATER THAN 22KAICPLA N CHECK FOR POWER AND ENERGY FOR RENOVATION OF EXISTING MARKET 600A RATED EQUIPMENT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74322	14041-20000-12216	14624 W SHERMAN WAY	91405	6	183B149   797	2219007031	[Q]C2-1L, [Q]C2-2D	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Commercial			05/07/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	01/13/2015 12:00:00 AM	ADDRESS	34.20102	-118.45165	TI in (E) medical office.  Low voltage nurse call, receptacles and outlets, and like-for-like replacement of all fixtures.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74323	15041-20000-17417	12701 W VAN NUYS BLVD B-2	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			06/05/2015 12:00:00 AM	06/05/2015 12:00:00 AM		Permit Finaled	12/03/2015 12:00:00 AM	ADDRESS	34.27621	-118.41056	Plan check for Title 24 only for PACOMIMA OFFICE BUILDING. Total area: 3193 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74324	13041-10000-24606	13076 W BEAVER ST	91342	7	228B161   363	2511031016	RS-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.32203	-118.4176	PV1 2.59KWAC 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 12) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 250 PE}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74325	17041-20000-36514	7077 W WILLOUGHBY AVE	90038	4	144B181   703	5531015009	[T][Q]C2-2D	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	10/11/2017 12:00:00 AM		Permit Closed	08/15/2019 12:00:00 AM	ADDRESS	34.08719	-118.34375	temp power for construction site for trailer only.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74326	17041-10000-29449	7531 N COLDWATER CANYON AVE	91605	2	186B161   373	2303021049	CM-1, P-1, [Q]P-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM	08/18/2017 12:00:00 AM		Issued	08/18/2017 12:00:00 AM	ADDRESS	34.20757	-118.41456	REMOVE EXISTING (5) HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AFFECTED AREA 16900 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74327	18041-10000-22067	6221 W 96TH ST	90045	11	093B165    89	4124024917	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			Corrections Issued	06/13/2018 12:00:00 AM	ADDRESS	33.94902	-118.39331	****MISSING BUILDING PERMIT  FOR FIXTURES OVER 30FT******PC FOR LAX NEW OUTDOOR PARKING LOT FOR TITLE 24 ENERGY ONLY.  TOTAL AFFECTED AREA 143880SQ.SCOPE OF WORK INCLUDES NEW PANEL, CIRCUITS AND LIGHTS. B# 18020-10000-00009 - FOR LAND RECONFIG	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74328	12041-10000-22830	1600 N CAMPUS ROAD	90041	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			09/25/2012 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	07/24/2013 12:00:00 AM	PIN	34.12750533	-118.21285206	on the Occidental College campus, remodel the first floor of the Johnson Hall South Buildingplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74329	16041-10000-16603	200 N SPRING ST 9TH FLOOR	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			05/11/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.05405	-118.24317	TI TO AN EXSITING OFFICE BUILDING. PLAN CHECK CHECK T-24 CITY HALL 738SQFT. 9TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74330	19041-20003-19951	112 N JUNE ST	90004	4	138B185   211	5515003007	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2019 12:00:00 AM			PC Approved	12/20/2019 12:00:00 AM	ADDRESS	34.07442	-118.33415	$0 PLAN CHECK FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET, REMOVAL OF PERFORMANCE METER AND UTILITY REQUIRED AC DISCONNECT FROM SINGLE LINE, ROOF PLAN, AND SIGNAGE PAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74331	14041-20000-04852	8419 N RATHBURN AVE	91325	12	192B125   430	2786019011	RS-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.22344	-118.53292	Roof mounted PV system with 4.75KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74332	14041-20000-35220	12105 W BLUFF CREEK DR	90094	11	105B165   936	4211010103	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	33.97901	-118.40436	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT. NEWLY CONNECTED LOAD > 400 AMPS. 10900 SQFT. 2 STORY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74333	18041-20000-11679	12039 N CARABELA CT	91326	12	216B109   296	2701083018	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.29167	-118.58305	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac/5.03 kWdc and consists of (15) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74334	18041-10000-19000	1107 S ALVARADO ST	90006	1	130-5A201 307	5136018020	C2-1-HPOZ	Central	Westlake	Pico Union		2098.10	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.05001	-118.28118	T-24, PC FOR ENERYG ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 16700 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74335	13041-10001-34384	6200 N PEACH AVE	91411	6	177B145   337	2242009011	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/03/2014 12:00:00 AM	ADDRESS	34.18323	-118.4673	Expedited RSES plan check per applicant request. {{[PV1, install 2.5 kw DC roof-mounted solar array for a 2-story house, interconnect with main panel. (1)Transformerless inverter(s): Solaredge SE3000A-US. (10) modules: Trina Solar TSM-250PA05.18.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74336	17041-20000-40676	550 S PALOS VERDES ST	90731	15	015B201    79	7455026050	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Apartment			11/09/2017 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	06/02/2020 12:00:00 AM	ADDRESS	33.73963	-118.28119	PLANCHECK FOR POWER AND ENERGY. NEW 7- STORY MIXED USE BUILDING WITH 375 RESIDENTIAL DWELLING UNITS WITH 5,200 SQ.FT. OF GROUND FLOOR COMMERCIAL SPACE (CORE & SHELL retail) OVER A SUBTERRANEAN GARAGE.FIRE ALARM VARIANCE HAS BEEN SUBMITTEDBUILDING PERMIT # 17010-10000-01378	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74337	10041-10000-06906	5400 N VAN NUYS BLVD	91401	2	172-5A151  16	2248014035	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1285.00	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	08/03/2010 12:00:00 AM		Permit Finaled	12/23/2011 12:00:00 AM	ADDRESS	34.16857	-118.44838	New vehicle dealership.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74338	18041-10001-27241	12105 W WATERFRONT DR STE B	90094	11	105B161  1199	4211010120	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/15/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	33.98095	-118.40764	Plan check for T-24 only first time tenant for a restaurant. Total area: 1500 sq ft. All Changes clouded under delta 1. Note: PC only. Permits fees have been paid under PCIS#18041-10000-27241	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74339	16041-20000-22352	19202 W SANTA RITA ST	91356	3	171B121   218	2163010006	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.16697	-118.55148	$0 permit fee due to State Senate Bill SB 1222. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 18.20 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74340	16041-10002-29267	6526 N GROSS AVE	91307	12	180B093   569	2036023023	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.18906	-118.64026	Changes to an approved set of plans. All changes are clouded under Delta 2. Scope includes adding an additional solar module on the roof-layout and on the single line diagram. (((((PV1 SFD TOTAL SYSTEM SIZE 10KW AC USING CENTRAL INVERTER SYSTEM WITH POWER OPTIMIZERS. TOTAL OF 40 MODULES IN TOTAL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74341	12041-20000-15428	6318 N VESPER AVE	91411	6	178-5A151  17	2241005017	[Q]C1.5-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.18525	-118.45078	T.I. to existing space.  Install general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-14530	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74342	17041-10000-30300	7311 W SUNSET BLVD	90046	4	147B181   598	5550017021	C4-1D	Central	Hollywood	Hollywood Hills West		1899.05	Electrical	Electrical	Commercial			08/24/2017 12:00:00 AM			PC Info Complete	08/24/2017 12:00:00 AM	ADDRESS	34.09817	-118.34929	PLAN CHECK FOR T24 ONLY FOR INTERIOR RENOVATION TO (E) RESTAURANT TO RE-OPEN. TO RENOVATE INTERIOR AND REPLACE ELECTRICAL FIXTURES FINISHES.REUSING EXISTING PANEL. ((B#17016-10000-23098))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74343	15041-10001-06766	1050 S GRAND AVE	90015	14	127-5A207 294	5139010003	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	ADDRESS	34.04171	-118.26155	Changes made to approved set.  Decreased riser feeder rating and size.  (((TEMPORARY POWER FOR CONSTRUCTION OF NEW HIGH RISE RESIDENTIAL BUILDING)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74344	12041-10001-19590	225 S GRAND AVE	90012	14	132A211    60	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Apartment			07/10/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.05388	-118.25078	changes to method supplying the fire pump; added service rated 3000A CB WITHIN ELECTRICAL ROOM WITH SERVICE EQUIPMENTPAT GILBERT GAVE IS BLESSING FOR THIS INSTALLATIONNEW HIGHRISE MIXED USE APARTMENT & COMMERCIAL (RESTAURANT) BUILDING OVER PRIVATE PARKING GARAGE. 22 STORIES W/ 1 LEVEL BASEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74345	18041-20000-00034	11287 W ALLEGHENY ST	91352	7	201B173   239	2538022013	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.24849	-118.37779	0$ permit fees due to senate bill 1222pv1install roof mounted pv sysem sized 11.2kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74346	14041-10000-32603	10430 W WILSHIRE BLVD 1-124	90024	5	135B157   223	4326036***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			11/21/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.06564	-118.43046	REPLACING AN EXISTING OLD EMERGENCY GENERATOR AND THE TRANSFER SWITCH IN AN EXISTING HIGH RISE BUILDING - LIKE TO LIKE. NO NEW LOAD ADDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74347	19041-10000-15416	1205 E WHOLESALE ST	90021	14	124-5A215  10	5164010005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.03668	-118.23818	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74348	14041-20000-34643	11201 N CHALON ROAD	90049	5	141B145   185	4369016005	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2014 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.08239	-118.46048	PC ONLY FOR POWER . NEW GATE HOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74349	13041-10000-03450	10250 W SANTA MONICA BLVD PARKING-LEVEL A	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/11/2013 12:00:00 AM			PC Approved	03/12/2013 12:00:00 AM	PIN	34.0586034	-118.41904766	PLAN CHECK FOR TITLE 24 IN INDOOR/UNDERGROUND PARKING GARAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74350	19041-20000-10842	939 S BROADWAY Ste 2	90015	14	127-5A209 322	5139003018		Central				2079.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.04157	-118.25708	TI to retail tenant space of adaptive reuse highrise building.  Plan check for energy.  Per applicant, only (1) exit out of retail tenant space - EM egress lighting not required.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74351	19041-20000-53154	110 E 9TH ST 4TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	02/18/2020 12:00:00 AM	ADDRESS	34.04107	-118.25479	TENANT IMRPOVEMENT ADD NEW LIGHTS. PLAN CHECK FOR ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74352	14041-10000-15574	1500 S CENTRAL AVE	90021	14	121-5A211 236	5130014025	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	08/08/2014 12:00:00 AM	ADDRESS	34.02704	-118.24799	Title 24 plan check only.  Total area = 12770 sq. ft.Remove HID light fixture and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74353	14041-10000-03905	14006 W RIVERSIDE DR SPC.#93	91423	4	168B153   929	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM	04/10/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.15713	-118.43792	permit to be pulled at EPC counter. PC for energy only. TENANT IMPROVEMENT TO (E) RETAIL SPACE INCLUDING DOORS, PARTITIONS, CEILINGS, AND FIXTURES. Z Gallerie. fees under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74354	16041-10001-09208	3500 W WILSHIRE BLVD	90010	10	132B193    40	5094001020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			08/25/2016 12:00:00 AM			PC Approved	08/25/2016 12:00:00 AM	ADDRESS	34.06157	-118.30077	"08/25/16Changes to an approved set of Plans. All changes are clouded under delta 1. Changes include emegency lighting source from battery back-up to inverter, revisions to single line diagram to reflect existing electrical equipment, and changes on floor plans for occupancy sensors, HVAC equipment, and existing panelboards that reflect what is on the field.  ((((TI to an (E) commercial build. Re-feeding panelboards under the  ""HDB"" and ""CDB"" total load over 400A. PC for Power and Energy. (2000MSA under separate permit).  Total area: 14,511 sq.ft indoor + 13,481 sq.ft outdoor."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74355	19041-20000-46956	333 S HOPE ST 40TH FLR-STE 4050	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	04/27/2020 12:00:00 AM	ADDRESS	34.05326	-118.25292	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS TITLE 24 PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74356	19041-10000-49497	1300 S SAN PEDRO ST STE 101	90015	14	123A211    69	5132019001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/03/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	01/17/2020 12:00:00 AM	ADDRESS	34.03256	-118.25392	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74357	14041-10000-35393	750 N HARPER AVE	90046	5	141B173   236	5528006027	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2014 12:00:00 AM	12/22/2014 12:00:00 AM		Permit Finaled	12/24/2014 12:00:00 AM	ADDRESS	34.08519	-118.36894	Installation of new roof mounted solar PV array.  Total system size = 5 kWac (22 modules, 2 strings, 1 inverter)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74358	13041-20000-07529	23104 W VICTORY BLVD	91367	3	180B097   612	2039012055	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2013 12:00:00 AM	04/24/2013 12:00:00 AM		Permit Finaled	05/10/2013 12:00:00 AM	ADDRESS	34.18623	-118.63018	solar single family 8 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74359	18041-10000-39467	444 S FLOWER ST 41ST FLR.	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	02/11/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	INTERIOR TI TO EXISTING RESTROOM, PUBLIC CORRIDOR AND ELEVATOR LOBBY. T-24 ENERGY ONLY. BLDG PERMIT: 18016-10000-28397	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74360	18041-20000-29916	474 W VISTA GLORIOSA DR	90065	1	144A221    52	5452013009	R1-1	East Los Angeles	Northeast Los Angeles	Greater Cypress Park	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.09056	-118.21881	Plan check for a PV1 roof-mounted PV system. System size is 12 kwdc/10.49 kWac-CEC and consists of (40) modules, (40) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74361	15041-10001-27101	12452 W OSPREY LANE Unit #1	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/19/2015 12:00:00 AM			PC Approved	08/24/2015 12:00:00 AM	ADDRESS	33.97922	-118.40984	EXPEDITE PER CUSTOMER REQUEST.PV2 installed roof mounted pv system for UNIT #1. Size 3KW, interconnected with the main service panel.(8)modules: SPR-230NE-BLK-D(1)PVI 3.0-OUTD-S-US inverter*****zone clearance for this application shall also covers Unit #2, and Unit #3 under this address.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74362	11041-10000-10787	345 S GRAMERCY PL	90020	4	135B193   386	5504024021	R4-1	Central	Wilshire	Greater Wilshire		2117.03	Electrical	Electrical	Apartment			05/25/2011 12:00:00 AM	10/12/2011 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.06755	-118.31312	new 5-stories  46-units apartment building with 8- types of units	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74363	15041-20000-00250	9328 N HAYVENHURST AVE	91343	12	198B137   433	2676002008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2015 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	01/30/2015 12:00:00 AM	ADDRESS	34.24011	-118.49358	PV1CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 5.0KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74364	17041-10000-04323	6600 N TOPANGA CANYON BLVD SPACE 43	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	08/02/2018 12:00:00 AM		Issued	08/02/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24, PC FOR ENERGY ONLY. TI TO AN EXISITING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGTHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS TI  Remodel of existing retail space inside the mall.  TOTAL AFFECTED AREA IS 3820 SQ. FT. B#17016-40000-02720 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74365	19041-10000-04115	523 W 6TH ST #1234	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/04/2019 12:00:00 AM	02/20/2019 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.04864	-118.25484	T-24 ENERGY ONLY PLAN CHECK FOR AN OFFICE SPACE TI IN A HIGHRISE. SCOPE INCLUDES NEW CIRCUITS AND LIGHTNG. TOTAL AFFECETED AREA IS 3410SQ.FTB# 19041-10000-00776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74366	19041-20000-15485	22702 W BERDON ST	91367	3	174B097   728	2040019011	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	04/26/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	34.17087	-118.62133	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM FOR EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK INCLUDES (2) 13.5 KWH 5KW TESLA POWERWALL BATTERIES AND A 225A LOAD CENTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74367	15041-10000-23795	14417 W BURBANK BLVD	91401	4	174B149   852	2245010033	C2-1VL, P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			07/24/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Finaled	09/02/2015 12:00:00 AM	ADDRESS	34.17231	-118.44702	Full plan check for a medical office ( Chiropractic) TI; Scope includes new lighting, equipment and receptacles. Total area is 1250-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74368	19041-20000-08884	5178 N MECCA AVE	91356	3	171B125   412	2161019003	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	04/18/2019 12:00:00 AM	ADDRESS	34.16516	-118.53735	Fees $0.00 due to California Senate Bill 1222 and AB 1414PLAN CHECK FOR NEW ROOFTOP PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 25.74KW DC, 23.743KW AC CEC. SCOPE OF WORK INCLUDES (78) PANASONICE PV MODULES WITH P400 OPTIMIZERS, (1) 125A AC LOAD CENTER, (1) 5KW TRANSFORMER, (1) 5KW RESU10H LG CHEM BATTERY, (1) SE7600H INVERTER, (1) SE7600A INVERTER,  AND (1) SE3800H INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74369	12041-10000-20468	1250 N TOWER GROVE DR	90210	5	144B157   145	4356026004	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2012 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	08/22/2013 12:00:00 AM	ADDRESS	34.09352	-118.4241	PV1 PLAN CHECK FOR 22.54 KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM  FOR SINGLE FAMILY DWELLING WITH DETACHED BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74370	18041-10000-27128	7519 N WOODMAN AVE	91405	2	186B157   158	2215002007	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.20714	-118.4315	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74371	11041-10000-21077	13227 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			10/03/2011 12:00:00 AM	11/30/2011 12:00:00 AM		Permit Closed	12/31/2012 12:00:00 AM	ADDRESS	34.31115	-118.42909	TENANT IMPROVEMENTS FOR DOLLAR TREE RETAIL STORE. Full P/check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74372	15041-10000-01530	1656 1/2 W 36TH PL	90018	8	120B193  1423	5041022014	R2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2225.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.02178	-118.30766	install roof mounted solar array, interconnect with main panel. system size: 7.65kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74373	17041-10000-43945	1011 S FIGUEROA ST B-101	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/07/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.04476	-118.26452	PC for T24 only for new lighting in existing restaurant. Installing new equipment and lighting. Total area is 1279sqft. B 17016-10000-22588.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74374	18041-10000-35092	6343 N LAUREL CANYON BLVD	91606	2	180B165   760	2334001063	C2-1L, P-1L	South Valley	North Hollywood - Valley Village	NoHo		1239.01	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.18618	-118.39672	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74375	18041-20000-02299	19707 W MERRIDY ST	91311	12	204B117   496	2726006009	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.25285	-118.56273	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter and (26) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74376	13041-10000-27130	6247 S FAIRFAX AVE	90056	11	105B177   393	4002005004	R2-1XL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	11/15/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	33.98272	-118.36144	PV1. ROOFMOUNTED SOLAR ARRAY. NON- STANDARD PLAN.  SYSTEM SIZE: 4.5 kW. TRANSFORMERLESS INVERTER. UNGROUNDED SYSTEM.(18) TRINA SOLAR # TSM-250PA05.18(1) POWER-ONE # AURORA PVI-4.2-OUTD-S-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74377	13041-10000-05851	150 S BARRINGTON AVE	90049	11	135B145   604	4401006011	C2-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Commercial			03/06/2013 12:00:00 AM			PC Approved	03/06/2013 12:00:00 AM	ADDRESS	34.06457	-118.46895	RENOVATION OF A KITCHEN SPACE. PC FOR T24 ENERGY COMPLIANCE FOR KITCHEN. PERMIT ALREADY ISSUED. T24 PC ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74378	13041-10000-27502	792 E 12TH ST	90021	14	123A211    98	5132012061	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM			PC Approved	10/18/2013 12:00:00 AM	ADDRESS	34.03226	-118.25077	Title 24 plan check for retail renovation as per inspector request.  Original permit issued under 13041-40000-11093.  (((LIGHTING / RECP. UPGRADE))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74379	17041-10000-05547	400-408 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	03/10/2017 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	ADDRESS	34.04446	-118.25616	PC fof Fire alarm with 12 devices and 1 fire alarm panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74380	19041-10000-14107	15140 W BLEDSOE ST	91342	7	222B145   103	2506002029	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM			Reviewed by Supervisor	04/24/2019 12:00:00 AM	ADDRESS	34.30714	-118.46302	Power plan check for a medium voltage equipment system  with a scope of 5KV 600Amp service including (1) 112.5KVA step transformer  Note:this project is dedicated for the 1st phase of a future PV system. the second phase is mainly PV modules and inveters feeding back to the grid # 19041-10000-14108	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74381	11041-10000-27233	3800 E NOAKES ST	90023	14	117A229    15	5192018008	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.20	Electrical	Electrical	Commercial			12/21/2011 12:00:00 AM	04/02/2012 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.01379	-118.19375	PLAN CHECK 37 KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR EXISTING OFFICE BUILDING WITH OPEN WAREHOUSE. INVERTERS LOCATED INSIDE OF WAREHOUSE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74382	16041-20000-08251	18133 W VENTURA BLVD 102	91356	3	171B125   271	2160017015	(T)(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			03/10/2016 12:00:00 AM			Verifications in Progress	04/21/2016 12:00:00 AM	ADDRESS	34.16603	-118.52861	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. 1ST FLOOR OF A 4-STORY MED BUILDING. LINAC (Linear Accelerator - Cancer treatment) clinic. 6,514sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74383	19041-20001-22805	423 W 14TH ST	90731	15	012B201   144	7456016011	R2-1XL-CPIO	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2019 12:00:00 AM	08/16/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.73135	-118.28627	08-16-2019 Changes to an approved set of plan, changes include, update to 2 gang meter change from central inverter to Microinverters. System size: 1.98KW with 6 PV modules and 6 microinverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74384	17041-10000-46004	1525 E WASHINGTON BLVD	90021	14	120A213   319	5129009011	M2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.02174	-118.24525	NEW UNDERGROUND  800A SERVICE  WITH STUB-OUTS FOR FUTURE USE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74385	17041-30000-24232	1561 N BLUE JAY WAY	90069	4	147B169   198	5561011008	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM			Reviewed by Supervisor	08/23/2017 12:00:00 AM	ADDRESS	34.10115	-118.38641	Plan check for power only. Project site is a new single-family dwelling. Work includes a new 600-amp service.Note: Building permit has been issued under 16010-40000-01879. Electrical permit fees have been paid under the building permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74386	14041-20000-22954	4142 S CHASE AVE	90066	11	108B157   110	4231020021	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	33.9957	-118.42981	PV1.  Install 5.00 kW roof-mounted, utility-interactive PV system.  Transformerless inverter with DC-DC converters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74387	15041-10000-15627	476 W 43RD ST	90037	9	114A201   306	5019029001	C2-1VL	South Los Angeles	Southeast Los Angeles	Voices of 90037		2317.20	Electrical	Electrical	Apartment			05/21/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.00542	-118.28215	Replacement of FACP, annunciator, and common area devices in (E) 4-story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74388	19041-10000-01161	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC T-24 ONLY FOR REMODEL OF ALSKA AIRLINE RAMP OFFICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74389	15041-10003-38856	8500 N BALBOA BLVD	91343	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			03/29/2017 12:00:00 AM			PC Approved	03/29/2017 12:00:00 AM	PIN	34.22443327	-118.49947932	03/29/17PC TO APPROVED SET. ALL CHANGES ARE CLOUDED UNDER DELTA 7. CHANGES INCLUDE RELOCATING LOADS ON THE PANEL SCHEDULES, AND REVISING SINGLE LINE DIAGRAM.NOTE: PERMIT IS PAID UNDER PCIS#15041-10000-38856	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74390	16041-10000-43693	1035 N SWARTHMORE AVE	90272	11	129B125   837	4423016022	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			12/19/2016 12:00:00 AM	10/26/2017 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.04825	-118.52512	Full Plan check for new retail and theatre building, core and shell, 1 story. New service rated at 5000 Amps 480/277V 3phase 4wire. Indoor and outodoor title 24. Total area: 7250.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74391	17041-20001-29311	7409 N WISCASSET DR	91304	12	186B085   151	2017036004	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.20686	-118.66044	Expedited per applicant request.Plan check a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters, (47) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74392	16041-10000-38356	3727 S GENESEE AVE	90016	10	117B173   146	5025001007	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2016 12:00:00 AM	10/28/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.01941	-118.37189	PV INSTALL 2.97 KW DC ROOF-MOUNTED  SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (11) MODULES: SUNEDISON SEF270KZD3Y(270)(1) INVERTER: SOLAREDGE SE3800A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74393	10041-10000-12254	11777 W FOOTHILL BLVD	91342	7	210B169   147	2530007011	RD2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District	YES	1041.06	Electrical	Electrical	Public Safety Only			06/28/2010 12:00:00 AM	06/28/2010 12:00:00 AM		Permit Finaled	09/01/2010 12:00:00 AM	ADDRESS	34.27318	-118.39223	REPLACE FACP; REPLACE MINI-HORNS IN APARTMENTS ; REPLACE MANUAL PULL STATIONS; NEW SMOKE DETECTOR IN THE ELECTRICAL ROOM;  REPLACE EXTERIOR BELLS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74394	13041-10000-21665	3475 E WHITTIER BLVD	90023	14	121-5A227 158	5188004036	C1.5-1	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			08/12/2013 12:00:00 AM			PC Approved	10/24/2013 12:00:00 AM	ADDRESS	34.02687	-118.19853	pc for energy only. permit to be pulled at EPC counter only. BankOfAamerica-ATM room LIGHTING: INDOOR (1 light) AND OUTDOOR (2 lights with photocell)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74395	13041-10001-32223	5939 N COLBATH AVE	91401	2	177B153   961	2246003021	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	11/26/2013 12:00:00 AM	ADDRESS	34.17863	-118.43674	Expedited RSES plan check per applicant request.(((PV1, Install 5.5 kW DC roof-mounted solar array for a single family dwelling, interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US. 22 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74396	16041-10001-43681	1626 S LONG BEACH AVE	90021	14	120A213   271	5167002038	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			Reviewed by Supervisor	12/20/2016 12:00:00 AM	ADDRESS	34.02242	-118.24254	Expedite fees. PV2 roof mounted solar system on commercial site. Installing a central inverter rated at 14.4 KW being fed by 68 solar modules and optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74397	17041-10000-43202	826 S BROADWAY	90014	14	127-5A209 180	5144016062	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.04302	-118.25516	REMOVE OUTDOOR  HID FIXTURES AND REPLACE WITH NEW LED FIXTURES, TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74398	19041-20000-12372	11007 W BELLAGIO PL	90077	5	141B149   178	4369016002	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.081	-118.4581	PLAN CHECK ONLY. PERMIT PAID FOR AND PULLED UNDER 15014-10000-02169NEW 600A SERVICE, (7) PANELS AND (160) BRANCH CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74399	18041-10000-10486	736 N NORTH BROADWAY #104	90012	1	133-5A215  61	5408024011	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			03/22/2018 12:00:00 AM	06/06/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.06133	-118.23863	T-24, PC for energy only.  Change of use from a poultry markert to a restaurant. Adding new lights, receptacles, and equipment. Total affected area 442sqft. B#18016-10000-08635	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74400	14041-10003-28878	10250 W SANTA MONICA BLVD	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM			PC Approved	01/18/2017 12:00:00 AM	PIN	34.0586034	-118.41904766	12/23/2016 Changes to an approved set of plans. Changes include add new smoke dampers, exhust fan and fan coil units on floor plan corridor area. Single Line Diagram and panel schedules are provided as reference. Changes has been clouded as delta 23Note: all new panel board and branch circuits are charged on 14041-10004-26004This project is phase 4 of Westfield Century City which includes level 1 and level 2 core and shell for tenant spaces and above ground parking garage on levels 3 through 5.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74401	18041-20000-24393	20744 W SPRUCE CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2018 12:00:00 AM	06/29/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.29485	-118.58617	pv1install roof mounted pv system sized 4kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74402	14041-20000-05230	5800 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.97397	-118.41979	ROOF-MOUNTED, PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74403	11041-10000-16193	17720 W BURBANK BLVD	91316	5	174B129   873	2159001226	P-1VLD	South Valley	Encino - Tarzana	Encino		1392.00	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.17207	-118.51921	T.I.  Exisiting 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing fixtres with LED fixtures. Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74404	13041-10000-34171	1637 E MAURETANIA ST	90744	15	036B213   555	7425024048	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	33.79045	-118.24339	Plan check for T24. Remove HID light fixtures and replace with new fluorescent fixtures for a commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74405	16041-20001-19402	3239 N PASADENA AVE Unit C	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/02/2016 12:00:00 AM			PC Approved	06/14/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	RSES expedited plan check per applicant request.  PV2.  Install 2 kW DC roof mounted PV system.  (7) modules with (1) 3 kW transformerless inverter with power optimizers.  3 of 3 PV systems proposed for property submitted concurrently.Zoning clearance obtained under 16041-20000-19398	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74406	18041-20000-02205	1251 N TOWER GROVE DR	90210	5	144B157   153	4356026017	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/19/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	34.09308	-118.42435	Plan check for power only. Project site is an existing single-family dwelling. Project scope is the addiiton of habitable area under a permitted deck and a service upgrade to 800 amps.Plan check only, Electrical permit pulled under Building permit number 18014-30000-00182Note: Building application has been generated under 18014-30000-00182.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74407	15041-10000-03096	11801 N FELLOWS AVE	91340	7	213B157    73	2524003022	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	05/20/2015 12:00:00 AM	ADDRESS	34.2839	-118.41981	PV1, 3KW AC ROOF-MOUNTED SOLAR ARRAY FOR A RESIDENTIAL HOUSE.(10)  MODULES SUNPOWER SPR-327NE-WHT-D (1) INVERTER ABB PV1-3.0-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74408	16041-20000-15230	705 N ALFRED ST #3	90069	5	141B173   424	5528001055	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/02/2016 12:00:00 AM			PC Approved	05/02/2016 12:00:00 AM	ADDRESS	34.08391	-118.3755	PLAN CHECK FOR T-24 ONLY, TENANT IMPROVEMENT  JUICE SHOP. TOTAL AREA: 485 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74409	13041-10000-19016	1401 E 3RD ST	90033	14	127-5A219  23	5172010002	M2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	08/02/2013 12:00:00 AM	ADDRESS	34.0452	-118.22515	permit to be pulled at EPC counter only. PC for energy only. less than 400A with emergency lighting. 1 storydescription from plans: TENANT IMPROVEMENT OFFICE SPACE FOR FIRST AND MEZZANINE LEVELS ONLY UTILIZING EXSTING ELECTRICAL SERVICES ALREADY AVAILABLE FOR THIS EXISTING BUILDING. TOTAL LOAD IS ONLY 60KW;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74410	15041-10000-09642	15474 W DUOMO VIA	90077	5	156B145   197	4378036019	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2015 12:00:00 AM	05/08/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	34.12386	-118.47023	PV1 9.03KW roof-mounted  microinverter system with (42) SW-270 Mono solar modules, (42) Enphse M215-IG interconnecting through a new solar load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74411	13041-10000-33449	100 N SAN VICENTE BLVD	90048	5	138B173  1322	4334007009	C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/02/2013 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.07487	-118.37833	in an active oil field, installation of a 100HP injection pump motor and a 200HP injection  pump motor and a 5HP ventilation fan-motor in Class I  Div 2 locations. switchgear and VFD s are in non-classified areas.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74412	19041-30000-09840	2049 S CENTURY PARK EAST Suite 3550	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site is a tenant suite in an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 593 sq. ft.Note: Building application has been generated under 19016-10000-03127	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74413	14041-10002-23855	1331 E 6TH ST	90013	14	126A215   289	5164008005	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	12/10/2015 12:00:00 AM	PIN	34.03848626	-118.23472481	Change to approved set by updating the fault current and adding (1) circuit for the exhaust fan in the electrical room. All changes are under delta-2, clouded area only. (((PC FOR POWER AND ENERGY. CHANGE A PORTION OF EXISTING WAREHOUSE TO RESTAURANT WITH OUTDOOR DINNING. NEW MEZANINE FOR STORAGE USE.TOTAL AREA = 7869 SQ FT (INDOOR)+ UNDIFINED OUTDOOR AREA(TO BE VERIFIED BY APPLICANT). B # : 14016-10000-12836.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74414	10041-20000-08275	7007 S AVALON BLVD	90003	9	102B205   611	6011009046	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Commercial			05/04/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	06/23/2010 12:00:00 AM	ADDRESS	33.976	-118.2654	T-24 lighting plan check for retail buildings and exterior.  Additional permit to existing permit #10041-70000-03142.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74415	14041-20000-34250	4749 N DENNY AVE	91602	2	168B177   586	2421016011	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	Apartment			12/11/2014 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	08/17/2015 12:00:00 AM	ADDRESS	34.1571	-118.36501	Plan check for power only. Upgrade service to 600A for apartment building - install new 600A distribution board and two new panels. Additional hour added for checking fault current to existing panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74416	19041-20000-08720	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/29/2019 12:00:00 AM	ADDRESS	34.17126	-118.58861	REPLACEMENT OF MEDICAL IMAGING EQUIPMENT IN EXISTING MEDICAL BUILDING, INCLUDE 1 NEW 100A PANEL AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74417	16041-20000-27463	4900 N SERRANIA AVE Office	91364	3	169-5A109  71	2166046026	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	34.15898	-118.58816	"Plan check for power only. Project site is an existing commercial building. Project scope is a service upgrade to 400-amps for Office Building (""MSB""). Submitted per applicant request. No new load is being added onto subpanels."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74418	10041-20000-20952	8401 N VAN NUYS BLVD UNIT 6	91402	7	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			10/21/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	11/30/2010 12:00:00 AM	ADDRESS	34.22308	-118.44896	T.I. to existing space for take-out restaurant (Subway).  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74419	12041-10000-08713	5350 N TYRONE AVE	91401	2	171B153   138	2248017038	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2012 12:00:00 AM	07/19/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.16815	-118.44419	Installation of a 7.9KW photovoltaic system on the roof of a SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74420	16041-20000-15640	19810 W SHERMAN WAY	91306	3	183B113    84	2135016013	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM	05/04/2016 12:00:00 AM		Permit Finaled	07/15/2016 12:00:00 AM	ADDRESS	34.20086	-118.56495	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (20) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74421	12041-10002-17970	380 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	(((3/28/2014- CHANGES MADE TO APPROVED SET. LOADS WERE SHIFTED AROUND AND LOAD CHANGES. no new panels but new circuits added. fees under inspection)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74422	14041-20000-24389	4553 N CANOGA DR	91364	3	166-5A105 293	2190001007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2014 12:00:00 AM	09/08/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.1497	-118.60206	pv1central/string inverter standard plan.  system size 6.0kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74423	17041-10000-37052	16002 W SUNBURST ST	91343	12	195B141    94	2672027008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.23442	-118.481	PLAN CHECK FOR A ROOF MOUNTED PV SYSTEM ON A SINGLE FAMILY DUWELLINGSYSTEM SIZE: 11.52KW ACSCOPE INCLUDES 32 AC MODULES AND A SUB-PANEL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74424	13041-10000-06710	5930 W FRANKLIN AVE	90028	13	150A191   192	5586027012	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			04/18/2013 12:00:00 AM			PC Info Complete	08/30/2013 12:00:00 AM	ADDRESS	34.10506	-118.31873	PLAN POWER AND ENERY FOR EXISTING 7-STORY HISTORIC CHURCH OF SCIENTOLOGY CELEBRITY CENTER BUILDING. NEW TWO 1000A SERVICES WITH NEW ELECTRICAL SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74425	15041-20000-12435	20334 W CHASE ST	91306	3	192B113   215	2781023001	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	05/07/2015 12:00:00 AM	PIN	34.22441031	-118.57682679	Plan check for PV roof mounted system 9.0kW  37 modules and 2 inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74426	11041-20000-15139	13803 W FOOTHILL BLVD	91342	7	225B153   381	2509002037	[Q]C2-1VL	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM	11/07/2011 12:00:00 AM		Permit Finaled	06/07/2012 12:00:00 AM	ADDRESS	34.31046	-118.43385	Plan check power and energy for new 2-story type building retail and medical office	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74427	17041-20000-45212	4618 E FERN PL	90032	14	141A229   109	5305041037	RD1.5-1	East Los Angeles	Northeast Los Angeles	LA-32		2013.01	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	10/02/2018 12:00:00 AM	ADDRESS	34.08183	-118.19076	INSTALLATION OF ENERGY STORAGE SYSTEM. 13.5 KWH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74428	11041-10002-20387	8158 W BEVERLY BLVD	90048	5	138B173   448	5511006031	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/30/2012 12:00:00 AM			PC Approved	04/30/2012 12:00:00 AM	ADDRESS	34.07591	-118.36736	DELTA 4 REVISION TO APPROVED PLANS. RELOCATE ATS AND VERIFIED FAULT CURRENT. NO CHANGE TO AIC RATING FROM PREVIOUS PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74429	15041-10000-09886	6381 W HOLLYWOOD BLVD	90028	13	148-5A187 157	5546005010	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1902.01	Electrical	Electrical	Commercial			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Closed	02/12/2024 12:00:00 AM	ADDRESS	34.10177	-118.32913	REPLACE EXISTING FIRE ALARM PANEL.  ADDING 78 NEW DEVICES IN THE BASEMENT AND FIRST FLOOR ONLY.  THIS IS PHASE 1 OF TWO.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74430	17041-20000-39573	11755 W WILSHIRE BLVD 16th Floor	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			11/01/2017 12:00:00 AM	11/02/2017 12:00:00 AM		Permit Finaled	01/29/2018 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for Title 24 only. Project site is the 16th floor of an existing commercial building. Project scope is a tenant improvement in E. lobby, restroom, and corridor. Total lighting area = 1,939 sq. ft.Note: Building application has been generated under 17016-10000-19731	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74431	17041-20000-23927	6302 N BECK AVE	91606	2	177B169   117	2335025017	R1-1, [Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Apartment			07/17/2017 12:00:00 AM	04/06/2018 12:00:00 AM		Permit Finaled	07/01/2020 12:00:00 AM	ADDRESS	34.18517	-118.38328	new two story apartment building.  800 amp service, plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74432	13041-10000-21568	11245-11255 N PASEO LOMASO	91326	12	210B113   222	2701075***	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			08/12/2013 12:00:00 AM	09/18/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.27587	-118.5772	Plan check for new 6 unit condo building with attached garages. Building C	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74433	17041-10000-37188	11913 W RUNNYMEDE ST	91605	2	186B169   543	2317013902	RD1.5-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Permit Finaled	12/22/2017 12:00:00 AM	ADDRESS	34.20585	-118.3925	REPLACE OUTDOOR HID LUMINARES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74434	10041-20000-12563	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	08/09/2010 12:00:00 AM	ADDRESS	34.05979	-118.41671	LIGHTING IN RESTROOM OF OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74435	12041-10000-16642	13332 W HUSTON ST	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	11/08/2012 12:00:00 AM	ADDRESS	34.15935	-118.42391	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74436	10041-10000-22348	8378 W MELROSE AVE	90048	5	141B173   497	5528016056	C4-1XL	Central	Hollywood	Mid City West		1944.00	Electrical	Electrical	Commercial			11/08/2010 12:00:00 AM	12/03/2010 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.08341	-118.37285	"TI in a retail. New service and panels. EPC for power and energy. CORE & SHELL ONLY.COMPLETE PLAN CHECK WILL BE REQUIRED FOR EACH TENANT.  <<<<<<Methaen Buffer Zone Level 1 with less than 2"">>>>>>>>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74437	14041-10000-00947	18419 W VENTURA BLVD	91356	3	171B125     7	2160008037	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	03/14/2014 12:00:00 AM		Permit Finaled	06/17/2014 12:00:00 AM	ADDRESS	34.16805	-118.53374	TI new tenanat change of use from retail to Pet Store, T 24 and power	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74438	13041-20000-33556	1020 E VERNON AVE	90291	11	111B145   239	4243027012	R1-1VLD	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2013 12:00:00 AM	12/23/2013 12:00:00 AM		Permit Finaled	01/03/2014 12:00:00 AM	ADDRESS	34.00319	-118.46243	New rooftop PV System for an existin sfr.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74439	16041-10000-45575	3737 S WATT WAY 4th floor-5th floor	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/29/2016 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	08/07/2017 12:00:00 AM	ADDRESS	34.01921	-118.28872	PC FOR TITLE 24 ENERGY ONLY. 4th and 5th floors in high riseSCOPE INCLUDES NEW LIGHTING AND NEW RECEPTECALES. TOTAL AFFECTED AREA OF 1560 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74440	19041-10000-10423	1800 S AVENUE OF THE STARS 14TH FLR	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/22/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Issued	03/26/2019 12:00:00 AM	ADDRESS	34.06095	-118.41786	PLAN CHECK FOR TITLE 24 ONLY FOR - PROPOSED INTERIOR TENANT IMPROVEMENT ON ENTIRE 18TH FLOOR; WORK TO INCLUDE NON-STRUCTURAL PARTITIONS, SUSPENDED CEILING, MILLWORK AND FINISHES; NO CHANGE OF USE - TOTAL AFFECTED AREA 22101SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74441	12041-10000-04816	1000 W TEMPLE ST	90012	1	133-5A211   4	5160031018	CW	Central	Westlake	Downtown Los Angeles, Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			03/02/2012 12:00:00 AM	05/16/2012 12:00:00 AM		Permit Finaled	02/08/2013 12:00:00 AM	ADDRESS	34.06171	-118.25046	REPLACEMENT OF BOILERS WITH GAS WATER HEATERS AND HUMIDIFIERS. (LOAD > 400A)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74442	16041-20000-29223	11895 N BALBOA BLVD	91344	12	216B133   447	2607001013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2016 12:00:00 AM	08/17/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.287	-118.50237	Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP. 9kW ungrounded system (6+3). (35) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74443	15041-20000-42064	4910 N TOPEKA DR	91356	3	168B121   100	2176029031	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	01/20/2016 12:00:00 AM	ADDRESS	34.15907	-118.54644	Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (44) modules, (44) micro-inverters, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74444	18041-20000-18778	268 S VAN NESS AVE	90004	4	135B189   173	5516010011	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			05/21/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.06921	-118.31543	Plan check for a PV1 roof-mounted PV system. System size is 10.8 kWac and consists of (33) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74445	13041-10000-23834	5801 S VERMONT AVE	90037	9	108B197  1442	5002016029	C2-1VL, P-1	South Los Angeles	South Los Angeles	Voices of 90037		2326.00	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			Verifications in Progress	12/11/2013 12:00:00 AM	PIN	33.98944411	-118.29205631	Existing Taco Bell restaurant TI in single-story building.  Removal of existing 2x4 fixtures and replacing with new can lighting.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74446	16041-10000-13424	2720 N GRIFFITH PARK BLVD	90027	4	150A205    12	5433026037	P-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	09/29/2016 12:00:00 AM	ADDRESS	34.10737	-118.27281	PC for energy only. Change of use from a restaurant to a new Starbucks cafe. Existing service, (2) new 225 A panels. Newly connected load is less than 400 amps. Adding new lighting and power. Total sqft = 1350	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74447	15041-10000-07232	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.07125	-118.35662	TI TO AN EXISTING 8 STORY PARKING STRUCTURE. SWITCHING EXISTING LIGHTING TYPE TO LED.  LIGHTING SPONSORED BY LADWP.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1,106,168.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74448	19041-20000-36386	12348 W VENTURA BLVD SUITE B	91604	2	162B165   270	2369002020	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	11/20/2019 12:00:00 AM	ADDRESS	34.14277	-118.40242	Plan check for Title 24 Energy only in existing space Tenant Improvement. Total area: 1087 sq ft. B#19016-20000-25896	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74449	19041-10000-42618	1830 N ECHO PARK AVE	90026	13	142-5A211 189	5420030028	[Q]C1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1973.00	Electrical	Electrical	Commercial			10/18/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	02/18/2021 12:00:00 AM	ADDRESS	34.0849	-118.25318	T-24, PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING (OUTDOOR AND INDOOR) AND RECEPTACLES TO (E) SPACE. TOTAL SQ FOOTAGE: 690 SQ FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74450	18041-20000-15772	325 S BOYLE AVE	90033	14	127-5A221  72	5174012009	[Q]R4-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights	YES	2060.32	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	ADDRESS	34.04403	-118.2199	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 4,435 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74451	19041-20000-15598	2925 1/2 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Closed	11/08/2021 12:00:00 AM	ADDRESS	34.10414	-118.24377	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74452	13041-10000-10036	3401 N BONNIE HILL DR	90068	4	159B177   557	2425027028	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2013 12:00:00 AM	04/23/2013 12:00:00 AM		Permit Finaled	05/14/2013 12:00:00 AM	ADDRESS	34.13008	-118.35381	PV1 SINGLE FAMILY DWELLING; 1-STORY HOUSE. INSTALL ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL. SYSTEM SIZE: 5.76 kW. TRANSFORMERLESS INVERTERS. TOTAL MODULES: 24. [INVERTER: SOLAR EDGE SE6000A-US] [MODULE:TRINA TSM-240-PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74453	10041-10000-12095	11941 W SAN VICENTE BLVD	90049	11	129B145    64	4404025025	C4-1VL	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	Commercial			06/24/2010 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Expired	02/13/2013 12:00:00 AM	ADDRESS	34.0528	-118.47095	REMODEL /EXPAND  (E)  PHARMACY AREA WITHIN A CVS PHARMACYPLAN CHK IS FOR TITLE 24 : LIGHTING CIRCUITS ARE ROUTED THROUGH THE EXISTING ENERGY MANAGEMENT SYSTEM	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74454	19041-20000-23780	23929 W BERDON ST	91367	3	174B089   646	2047011034	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.16921	-118.649	PLAN CHECK FOR NEW ROOFTOP SOLAR ON A EXISTING SFD. SYSTEM SIZE IS 11.55 KW DC/9.81KW AC. SCOPE OF WORK INCLUDES (35) PANASONIC 330W PV MODULES WITH P400 OPIMIZERS AND A SE11400H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74455	14041-10000-18660	3627 S HUGHES AVE	90034	5	120B165   428	4313008006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	34.02695	-118.40178	NEW fire alarm for new bldg: 4 LEVEL TYPE V-A  27 - UNIT APARTMENT  BUILDING  OVER GROUND  LEVEL TYPE I-A PARKING GARAGE & ONE LEVEL SUBTERRANEAN  GARAGE. ( 5 STORY ABOVE GROUND).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74456	17041-10000-25236	1313 W SEPULVEDA BLVD #1	90501	15	042B193   827	7347018096	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	09/24/2018 12:00:00 AM	ADDRESS	33.81424	-118.30074	PC FOR FIRST TIME TENANT FOR RESAURANT. TOTAL CONNECTED LOAD  <400A.SCOPE INCLUDES NEW PANELS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA 1950 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74457	13041-20001-00890	8556 W 3RD ST	90048	5	138B173   741	4334009027	C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/01/2013 12:00:00 AM			PC Approved	05/01/2013 12:00:00 AM	ADDRESS	34.07343	-118.37888	((CHANGES MADE TO APPROVED SET OF PLANS. ADDITION OF CHADELIER AND 2X2 FIXTURE INSTEAD OF 2X4.)) T24 PC FOR ENERGY. TI EXISTING BAKERY PER 06016-30000-29170. Per applicant, not hazardous because they do not store flour there.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74458	19041-10000-40895	3616 S MAPLEWOOD AVE	90066	11	111B149   302	4245011008	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	03/18/2020 12:00:00 AM	ADDRESS	34.00273	-118.44688	[E-PLAN]. PV1.  Installation of a 10.0  KW AC battery system, consisting of 2 Tesla AC Powerwall 2.0 Battery, 1 Tesla Gateway Disconnect and 1 backup sub panel in a residential home.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74459	18041-20001-25844	1021 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197    80	5037026017	P-1, [Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM			PC Approved	10/11/2018 12:00:00 AM	ADDRESS	34.01107	-118.29278	Medical office TI. Plan check for power and energy.  (((Install (12) lights, and (70) units (outlets and switches).  (Permit #1 of 2))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74460	18041-10000-29634	1947 S HOOPER AVE	90011	9	120A213   394	5129005001	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/07/2018 12:00:00 AM		Permit Closed	01/26/2024 12:00:00 AM	ADDRESS	34.02086	-118.24702	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74461	11041-20000-23373	444 S SAN VICENTE BLVD 8th Floor	90048	5	135B173    35	5510005044	C2-1L-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/01/2011 12:00:00 AM			PC Approved	11/01/2011 12:00:00 AM	ADDRESS	34.07021	-118.37547	T.I. To existing office space.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74462	19041-20001-12659	15693 W OLDEN ST	91342	7	225B141    39	2603019011	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	34.31724	-118.47345	Expedited plan check fee.PV1.  Install 15.37 kW DC / 13.6 kW AC roof mounted grid tied PV system.  (53) modules with 6 and 7.6 kW rated string inverters.  Main service disconnect derate to 150A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74463	13041-10000-15730	1967 W SLAUSON AVE	90062	8	108B189  1278	5005018030	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			06/14/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	11/07/2013 12:00:00 AM	PIN	33.98941725	-118.31329656	New 4-unit retail building.  New service and main switchboard subfeeding new building as well as existing Family Dollar grocery store.  4,640 sq ft, single-story building.  Power and energy plan check. Methane Buffer Zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74464	19041-10000-51867	734 S VALENCIA ST	90017	1	130-5A205 144	5142021021	C2-2D	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			12/16/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	34.05219	-118.26979	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T-24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74465	18041-10000-46584	5921 W CENTER DR 1-95	90045	11	102B169   962	4104023019	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	33.97588	-118.38747	FULL PLAN CHECK FOR FIRST TIME TENANT AND CHANGE OF USE FROM RETAIL (1,505 SQ FT) TO YOGA (HEALTH CLUB/STUDIO) . NEW 225A PANEL IS ADDED TO EXISTING SERVICE UNDER THE CORE AND SHELL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74466	15041-20002-25056	18124 W CHARDON CIR	91316	5	165B125   165	2184031030	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM			PC Approved	09/08/2015 12:00:00 AM	ADDRESS	34.15004	-118.52891	09-08-2015 Change to approved set of plans. Changes includes main panel from 400A split bus to 225A bus. Service load calculation is included. {{{{{{{Plan check for a PV1 roof-mounted PV system. System size is 20 kWac and consists of (4) inverters, (90) modules, and (1) load center.Note: $0.00 permit fees due to Senate Bill 1222}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74467	17041-10000-36029	11601 W WILSHIRE BLVD #104	90025	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/06/2017 12:00:00 AM	10/16/2017 12:00:00 AM		Permit Finaled	01/08/2018 12:00:00 AM	ADDRESS	34.05075	-118.45961	PC FOR TI  FOR COMMERCIAL OFFICE FOR TITLE 24 ENERGY ONLY.  NO CHANGE IN EXISTING USE OR OCCUPANCY. SCOPE INCLUDES NEW PANEL, CIRCUITS,  EQUIPMENT AND LIGHTS.TOTAL AFFECTED AREA 4380 SQ.FT.B# 17016-10000-24780	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74468	13041-10000-15281	12045 W WATERFRONT DR # 400	90094	11	105B161  1200	4211011028	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM	06/11/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	33.98209	-118.40611	RENOVATE EXISTING OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74469	16041-10002-20534	400 W 8TH ST	90014	14	127-5A209 301	5144018031	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/14/2018 12:00:00 AM			PC Approved	02/14/2018 12:00:00 AM	ADDRESS	34.04446	-118.25616	02-14-2018 Changes to an approved set of plans. Changes include revised circuit breaker from 400A to 800A and 800A to 400A. Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74470	13041-20001-11045	1305 S ABBOT KINNEY BLVD	90291	11	108B145  1166	4239027002	C2-1-O-CA	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Commercial			08/06/2014 12:00:00 AM			PC Info Complete	08/06/2014 12:00:00 AM	ADDRESS	33.99127	-118.46797	ADDITION OF 11 OUTDOOR HEATERS AND COMPRESSOR UNIT ON ROOF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74471	19041-20000-34343	888 S HOPE ST Suite 122	90017	14	127-5A209  28	5144020196	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	02/28/2020 12:00:00 AM	ADDRESS	34.0452	-118.25996	Power and lighting for first time tenant for new restaurant in mixed use building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74472	14041-20000-25250	600 S LA BREA AVE	90036	4	135B181   585	5507023026	C2-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.06474	-118.34381	TI TO AN EXISTING ONE STORY COMMERCIAL BUILDING.  ADDING LIGHTING USING EXISTING POWER EQUIPMENT.  4995 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74473	15041-20002-42469	4600 N VANALDEN AVE	91356	3	168B117   538	2177003001	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.15362	-118.55422	EXPEDITER PER APPLICANT REQUEST.(((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.5KWac/ 8.4KWdc. (30)MODULES-SOLARWORLD 280 MONO BLACK(30)MICROINVERTERS-ENPHASE M250	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74474	10041-20000-22448	677 N FARING ROAD	90077	5	144B153   831	4358002001		West Los Angeles				2621.00	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2010 12:00:00 AM	12/06/2010 12:00:00 AM		Permit Finaled	02/28/2013 12:00:00 AM	PIN	34.08863094	-118.43561102	Revision to approved plans (05041-30001-01783) as built drawings change genarotor size relocate panels reduce transfer swich to one total load is been reduce.  All changes from previusly approved plans are clouded and indicate by Delta 2 as shown on plans.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74475	15041-20000-37968	1655 N SERRANO AVE 1-40	90027	13	148-5A193 139	5544021029	C2-1	Central	Hollywood	East Hollywood		1905.10	Electrical	Electrical	Apartment			11/10/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.1014	-118.30734	New Fire alarm installation on 5 story build + 1 sublevel garage. 181 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74476	14041-20001-21931	11601 W WILSHIRE BLVD Ste 2040	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM			PC Approved	10/23/2014 12:00:00 AM	PIN	34.0509267	-118.45996763	[[[[[10/23/14 Changes to approved Title 24. Increasing a few fixtures. Delta 1 and delta 2 changes only. ]]]]]Title 24 plan check only on a comereical building Suite 2040. Total working area is 6000 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74477	14041-10000-09666	1040 S LOS ANGELES ST 1-9	90015	14	126A209   222	5145020004	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/11/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	02/14/2017 12:00:00 AM	ADDRESS	34.03858	-118.25669	"plan check for power and energy. methane zone. new 2 story. no common roof per applicant. 1of2 (service fees under bldg A).  BLDG#12010.10.01396: PROPOSED NEW  WHOLESALE/RETAIL BUILDING ""A"" 20' X129' (TOTAL 9 SPACES) TYPE VA CONSTRUCTIONChanges on plan include (FUTURE AC - for load calc purposes only and GEC is #3/0)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74478	17041-10000-10283	101 N GLENDALE BLVD	90026	13	135A209   425	5159014019	C2-1-O	Central	Westlake	Greater Echo Park Elysian	YES	2083.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM			PC Info Complete	09/20/2017 12:00:00 AM	ADDRESS	34.06228	-118.26001	PC for power and energy for new mixed use building (Cafe and Apartment) with 1 level of subtarrenean parking, 2 above grade parking, 5 residential stories with 55 units. PC for 120/208V 2000A service in methane zone.  Building permit under 16010-10000-04653.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74479	10041-20001-19848	1812 W VENICE BLVD #1812	90006	1	126B197   195	5075020041	CM-2	South Los Angeles	South Los Angeles	Pico Union		2212.20	Electrical	Electrical	Commercial			02/03/2011 12:00:00 AM			PC Info Complete	02/03/2011 12:00:00 AM	ADDRESS	34.04402	-118.2939	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR COMMERCIAL AREA TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74480	19041-10000-02044	11554 N HUNNEWELL AVE	91342	7	213B165   419	2531022034	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	34.28035	-118.39682	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.76KWdc / 3.80KWac.(16)MODULES-HYUNDAI HIS-S360RI(16)OPTIMIZERS-SOLAREDGE P400(1)INVERTER-SOLAREDGE SE 3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74481	15041-20000-23527	8124 W 3RD ST	90048	5	138B173   960	5511029032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/28/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.0721	-118.36676	Title 24 plan check only.  Total area = 1,110 sq. ft. (indoor) + 1,200 sq. ft. (outdoor) Addition of one new house panel to existing service and distribution equipment.  Installation of lighting for common area of building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74482	11041-20000-08117	300 S EARLE ST Berth-225-232	90731	15	018B205    71	7440027914	[Q]M3-1	Harbor	Port of Los Angeles			2961.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	11/21/2012 12:00:00 AM	ADDRESS	33.74527	-118.2666	Canopy P.V. mounted with 119.88 KW system for Port of L.A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74483	18041-20001-21442	1468 N KINGS ROAD	90069	4	147B173   381	5555019006	R1-1-HCR	Central	Hollywood	Bel Air-Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM			PC Approved	06/18/2018 12:00:00 AM	ADDRESS	34.09749	-118.37305	Expedite per applicant requestPlan check for PV battery back up system, system size:15.2kWac with 23 modules, 2 inverters(7.6kW), 2 9.8kWh LG Chem.  connected to 200A Service with derate main breaker.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74484	14041-10001-34612	1946 N VEDANTA PL	90068	4	150A187    78	5576019065	R2-1	Central	Hollywood	Hollywood United	YES	1896.00	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM			PC Approved	03/25/2015 12:00:00 AM	ADDRESS	34.10664	-118.32769	Permit for point of interconnection located at 1946 Vedanta Pl. (((PV1.  Install 9.483 kW roof-mounted, utility-interactive PV system.  Array and inverter proposed to be installed on roof of 1943 S. Vine St.  Point of interconnection to be at service point of 1946 Vedanta Pl.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74485	15041-10000-21783	23201 W VENTURA BLVD	91367	3	171B093   666	2044026040	R1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	03/02/2018 12:00:00 AM	PIN	34.16278687	-118.63118754	T-24 TO AN (E) BUILDING. INTERIOR OF EXISTING GAS STATION CONVENIENCE STORE AND REMODEL RESTROOM. PC FOR ENERGY ONLY. TOTAL SQ FT 1302.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74486	10041-20000-21386	1900 S AVENUE OF THE STARS 26th Floor	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/27/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Expired	12/10/2010 12:00:00 AM	ADDRESS	34.05979	-118.41671	Plan check T24 Energy general/emergency lighting for restroom on the 26th floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74487	17041-10000-40911	1843 S DUNSMUIR AVE	90019	10	126B177   721	5064004019	RD1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	11/28/2017 12:00:00 AM	ADDRESS	34.04203	-118.35652	PC FOR ROOF MOUNTED PV ON SFD. TOTAL SYSTEM SIZE 4.5KWDC/ 3.6KWACSOCPE INCULDES 15 MODULES WITH CENTRAL INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74488	15041-10001-27022	12700 W MILLENNIUM #45	90094	11	102B161  1274	4211037030	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	33.97639	-118.41499	PV1 1.5KW ROOF-MOUNTED SYSTEM WITH (6) (spr-x20-250 SUNPOWER AC-MODULES INTERCONNECTING THROUGH A SUB-PANEL. APPLICATION IS PLAN CHECK ONLY, PERMIT FEE IS PAID UNDER 1S 15041-90000-26266	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74489	19041-10000-37393	649 E MANCHESTER AVE	90001	9	097-5A207 284	6029032028	C2-1-CPIO	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2398.02	Electrical	Electrical	Commercial			09/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/15/2019 12:00:00 AM	ADDRESS	33.96031	-118.26333	REMOVE HID FIXUTRES AND REPLACE WITH NEW LED FIXTURES -T/24 ONLY OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74490	12041-10000-02932	12422 W BLUFF CREEK DR	90094	11	102B161  1153	4211010079	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			02/08/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	10/24/2012 12:00:00 AM	ADDRESS	33.97704	-118.40702	"PLAN CHECK POWER ANND ENERGY FOR INTERIOR TENANT IMPROVEMENTS ""YOU TUBE"" BROADCAST STUDIO AND OFFICE.  SITE IN METHANE ZONE"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74491	13041-10000-02979	21300 W VICTORY BLVD	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM			PC Approved	02/07/2013 12:00:00 AM	ADDRESS	34.18813	-118.59618	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING IN EXISTING OFFICE BUILDING (TENANT IMPROVEMENT). Replacement of existing luminaires. 7368 SQUARE FEET USING AREA CATEGORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74492	19041-10000-43307	11938 W DOROTHY ST 1-8	90049	11	129B145   541	4265021035	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			10/23/2019 12:00:00 AM			Reviewed by Supervisor	11/13/2019 12:00:00 AM	ADDRESS	34.04981	-118.46917	FULL PLAN CHECK FOR A NEW 800A SERVICE FEEDING A 400A AND A 600A SWITCHBOARDS. SCOPE INCLUDES NEW 40HP ELEVATOR. TOTAL AFFECTED AREA IS 8,620 SQ.FTFIRE VARIENCE SUBMITTEDPER BUILDING APPLICATION #18010-20000-02883: NEW TYPE VA 4-STORY APARTMENT WITH TYPE 1A SUBTERANEAN  GARAGE - 1 OF 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74493	17041-10000-24280	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	12/01/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	PC for power and energy for new food court area in LAX terminal 3. Load over 400A with total affected area of 4165 sqft. Building 17016-10000-19705.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74494	13041-10000-25217	224 W 115TH ST	90061	15	084B201    60	6087005010	R2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			09/13/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	33.92997	-118.27689	PV1 ROOF-MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE 1.715 KW DC, XFORMERLESS SYSTEM IN 2-STORY HOUSE.(7) TRINA-245(1) POWER-ONE-PVI-3.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74495	12041-20000-00932	23030 W HATTERAS ST	91367	3	174B097   193	2041016031	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2012 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.17539	-118.62859	Photovolatic system on roof of single family dwelling, including service panel upgrade to 225A.  Contact Joy at 775-230-5919 when ready for pickup.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74496	10041-20000-23338	800 W OLYMPIC BLVD A130	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	11/22/2010 12:00:00 AM		Permit Finaled	05/31/2011 12:00:00 AM	ADDRESS	34.04484	-118.26453	Install outdoor lighting for a restuarant.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74497	18041-10000-17193	1501 W 6TH ST	90017	1	132A205    98	5153006025	C2-2	Central	Westlake	Westlake North		2091.02	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	08/28/2020 12:00:00 AM	ADDRESS	34.05675	-118.26813	TI IN AN EXISTING BURGER KING RESTUARANT.PLAN CHECK FOR TITLE 24 - ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74498	14041-10001-17977	4827 S CENTRAL AVE 1-118	90011	9	111A209   103	5108021026	C2-1VL	South Los Angeles	Southeast Los Angeles			2292.00	Electrical	Electrical	Apartment			12/15/2014 12:00:00 AM	12/15/2014 12:00:00 AM		Permit Finaled	02/02/2015 12:00:00 AM	ADDRESS	33.99948	-118.25668	Changes to approved FA plans. addition of some devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74499	16041-20000-01281	6311 W ROMAINE ST #7100	90038	13	144B185   737	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			01/13/2016 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.08902	-118.32929	Plan check for energy only. TI to bathrooms and main entry/elevator lobby on the 1st floor of existing office building. New lighting (incl. emergency). 425sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74500	15041-10000-27847	8500 W BEVERLY BLVD SUIT DEPT	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/25/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	08/18/2016 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR ENERGY ONLY, T-24. TI IN THE SUIT DEPARTMENT WITH IN BLOOMINGDALE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1014	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74501	19041-10000-50532	1019 E ELKGROVE AVE	90291	11	111B145   625	4243003039	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			12/09/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.00073	-118.45937	PC FOR ENERGY ONLY, SCOPE F WORK IS A CHANGE OF USE, SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS. TOTAL AFFECTED AREA IS 985 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74502	17041-10000-35323	512 S AVENUE 20	90031	1	136-5A221 305	5410018030	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.06711	-118.218	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 6875 SQ. FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74503	10041-20000-08895	444 S FLOWER ST	90071	9	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	01/25/2012 12:00:00 AM	ADDRESS	34.05189	-118.25546	Plan check outdoor lighting T-24 Energy for existing high rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74504	14041-20001-29309	9959 W RANCHO CABALLO DR	91040	7	204B181   276	2543015076	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM			Reviewed by Supervisor	11/14/2014 12:00:00 AM	ADDRESS	34.25271	-118.34839	EXPEDITE PER APPLICANT REQUEST[PV1Install roof-mounted solar array on SFD. Interconnect with MSP. System size: 6.45kW.30 EnPhase M215 microinverters. 30 250W pv modules. 2 strings (15+15).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74505	16041-10000-06191	12775 W MILLENNIUM #135	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/22/2016 12:00:00 AM	04/11/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	33.97584	-118.4171	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO NEW FITNESS/GYM. TI TO AN EXISTING COMMERCIAL BUILDING (FITNESS CENTER). SCOPE INCLUDEW NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 3,400 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74506	12041-20000-08177	1051 N VISTAGRANDE DR	90272	11	132B121   422	4420025036	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM			PC Info Complete	04/10/2012 12:00:00 AM	ADDRESS	34.05606	-118.55074	upgrade service to existing building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74507	14041-20000-34831	700 S FLOWER ST #2990	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/16/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	T.I. to existing high rise building on 29th floor.  Install general/emergency lighting.  Plan check for energy only.Note: Permit is under a separate application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74508	12041-20000-16359	750 S ALAMEDA ST	90021	14	123A215     9	5166031009	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM			PC Approved	07/16/2012 12:00:00 AM	ADDRESS	34.03162	-118.23863	T-24 lighting plan check for remodeled office, lobby and warehouse area of building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74509	17041-10000-44588	115 S GRAMERCY PL	90004	4	138B193  1101	5516017018	[Q]RD1.5-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.07263	-118.31259	PC for new 5.8 kVA tesla powerwall in SFD. Installing new powerwall and 200A load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74510	19041-10000-32985	238 S RAMPART BLVD	90057	13	136-5A203 287	5155025017	R4-1	Central	Westlake	Echo Park	YES	2086.20	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	09/19/2019 12:00:00 AM	ADDRESS	34.06724	-118.27796	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74511	13041-20000-07244	7100 N VAN NUYS BLVD	91405	6	183B149   161	2217007052	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			03/20/2013 12:00:00 AM	04/08/2013 12:00:00 AM		Permit Finaled	08/09/2013 12:00:00 AM	ADDRESS	34.19938	-118.44856	Plan check for power and energy for medical office. No patient beds. General care only. Clinic will not be licensed by the Department of Public Health.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74512	17041-20001-10886	19915 W FRIAR ST	91367	3	180B113   797	2134025019	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.01	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2017 12:00:00 AM			PC Approved	04/19/2017 12:00:00 AM	ADDRESS	34.1866	-118.56685	expeditepv1install roof mounted pv system sized 7.6kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74513	16041-10000-41454	500 N PIER A ST	90744	15	027B205   619	7440009911	PF-1D	Harbor	Port of Los Angeles, Wilmington - Harbor City	Wilmington		9800.31	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	33.76414	-118.26561	New fire alarm system for a single lot, one address with 19 building structre . Scope include (1) main fire alarm panel, (14) power supplies, and (382) fire alarm devices interconnecting with the existing fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74514	15041-20000-07277	13411 W RIVERSIDE DR Bldg #19	91423	4	168B157   230	2359019004	[Q]RD1.5-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			03/12/2015 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	04/13/2018 12:00:00 AM	ADDRESS	34.15778	-118.4248	Service upgrade to existing apartment building.  New 600 A service and switchgear.  Subpanels are being replaced to accomidate increased (future) load.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74515	11041-20001-23724	12216 W ADDISON ST	91607	5	171B165  1113	2356012003	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2012 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	02/06/2012 12:00:00 AM	ADDRESS	34.16113	-118.39944	Changes from previously approved.  Changes include add a new 125 A subpanel,  and replace breaker.  *****New 3.84 KW DC roof mounted solar system for a single family residence.  There is already an existing system in place that the new system will tie into.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74516	12041-10000-21069	10878 W KINROSS AVE	90024	5	132B153   200	4363022003	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM			PC Approved	09/06/2012 12:00:00 AM	ADDRESS	34.06061	-118.44472	TENANT IMPROVEMENT TO EXISTING TAKE-OUT RESTAURANT (560 SQ FT) EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74517	12041-10000-15715	215 S OCEAN FRONT WALK	90291	11	109-5A141  88	4286030013	C1-1	West Los Angeles	Venice	Venice		2734.00	Electrical	Electrical	Commercial			07/06/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	02/11/2013 12:00:00 AM	ADDRESS	33.99485	-118.48052	T.I. FOR (E) RETAIL SPACE; CHANGE TO A YOGURT SHOP , title 24 , emergency lites, new panels and New 400 Amp UNDERGROUND SERVICE IN A METHANE ZONE.  <<<This plan check is ONLY for T-24, per  applicant's request.  This Plan is NOT checked for Methane.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74518	14041-20001-12043	12655 W SANDHILL LANE UNIT 3	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			05/06/2014 12:00:00 AM			PC Approved	06/10/2014 12:00:00 AM	ADDRESS	33.97753	-118.41457	((EXPEDITE FEES)))pv2 multifamily rooftop mounted solar. this is part of series. 3 systems connected to single service. this system is for unit #3. 3/3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74519	14041-10000-34918	6240 N SYLMAR AVE	91401	6	177B153   320	2240010***	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			12/17/2014 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	07/27/2017 12:00:00 AM	ADDRESS	34.18357	-118.44639	Title 24 plan check only.  Total area = 1,259 w. ft. (indoor) and 300 sq. ft. (outdoor)T.I. to existing police station.  Addition of one new elevator (max 20 amps), recepticles, lighting, and relocation of two fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74520	14041-20000-24581	6430 W SUNSET BLVD #400, #415	90028	13	147A187   153	5546014047	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			09/09/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	11/06/2014 12:00:00 AM	ADDRESS	34.09782	-118.32979	Plan check for energy only. TI to suites 400 and 416 in existing high rise office building. 7,857sqft. New lighting, incl. emergency. 2008 Title 24 standards (building permit filed before July 1st, 2014).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74521	11041-20000-27359	420 S GRAND AVE #200	90013	14	130-5A211  84	5149029***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM			PC Approved	11/13/2012 12:00:00 AM	PIN	34.05085086	-118.2528414	energy plan check fan room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74522	16041-10000-29079	4222 N VINELAND AVE	91602	2	165B173  1260	2366020002	[Q]C2-2D-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM	08/16/2016 12:00:00 AM		Permit Finaled	10/27/2016 12:00:00 AM	ADDRESS	34.1455	-118.37004	Replacement of fire alarm control panel.  All other devices to remain existing.  Battery calculations updated.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74523	12041-20000-27596	8466 S FIGUEROA ST	90003	8	097-5A201 129	6032035026	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	33.96195	-118.28249	Plan check for power, energy, and fire alarm. New two story charter school.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74524	16041-30001-01093	6474 N LANGDON AVE	91406	6	180B145   579	2234015006	RE11-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	1 or 2 Family Dwelling			01/12/2016 12:00:00 AM			PC Approved	03/18/2016 12:00:00 AM	ADDRESS	34.18863	-118.46898	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (65) modules, (1) load center, and (2) combiner boxes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74525	12041-20000-13074	3900 N STANSBURY AVE hillside	91401	5	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1417.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	06/06/2012 12:00:00 AM		Permit Finaled	08/30/2012 12:00:00 AM	PIN	34.14040392	-118.44322706	Permit for panels and branch circuits.  Note: Lighting plan check under 12041-20000-13066	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74526	19041-20000-42985	1444-1450 S REXFORD DR	90035	5	129B165    44	4306007004	[Q]R3-1-O	West Los Angeles	West Los Angeles	South Robertson		2691.00	Electrical	Electrical	Apartment			10/22/2019 12:00:00 AM	01/14/2021 12:00:00 AM		Issued	01/14/2021 12:00:00 AM	ADDRESS	34.05377	-118.39413	1600A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74527	17041-20000-11241	11500 W OLYMPIC BLVD	90064	11	123B153   157	4260016007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	11/16/2017 12:00:00 AM	ADDRESS	34.03624	-118.44415	"PLANCHECK FOR EMERGENCY LIGHTING IN STAIRWELLS. ""COMPLY WITH DEPARTMENT ORDER effective date11/30/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74528	16041-10000-04166	800 W WILSHIRE BLVD 3rd floor	90017	14	129A209    26	5144008010	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/05/2016 12:00:00 AM			PC Approved	02/05/2016 12:00:00 AM	ADDRESS	34.0493	-118.25841	T-24, PC ONLY. TI TO THE 3RD FL RESTROOMS. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL SQ. FT. 550. NOTE: INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT # 16041-10000-02776	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74529	18041-20000-36855	12854 N EL DORADO AVE	91342	7	222B145   251	2604017015	R1-1-K	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.30381	-118.46824	Plan check  for PV roof mounted system, system size: 13.5KW DC, 12.0KW AC with 41 PV modules and 2 inverters(6.0kW) connected to MSP.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74530	16041-20001-23917	14358 W MAGNOLIA BLVD 1-95	91423	4	171A151    50	2248009025	R3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.16469	-118.44621	RSES expedited plan check per applicant request.  PV2.  Install 55.8 kW DC roof-mounted PV system.  (180) modules with (4) 11kW transformerless central inverters.  System 1 of 2 for this parcel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74531	17041-10001-38192	10250 W SANTA MONICA BLVD #1430	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM			PC Approved	01/18/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Changes to approved set, noted as Delta-3. Replace F1 fixture to a track light fixture with Silver Bullet current limiter, add F8 (track light with silver bullet current limiter) and F9 fixture; Revise lighting floor plan and T24 information accordingly. ((first time tenant space ""VIDEO & AUDIO CENTER""  suite 1430)).**This is plan check only, permit is covered under master permit #17041-10000-38192"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74532	17041-10001-04265	515 S FLOWER ST	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	01/12/2024 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC FOR A LOST SET OF PLANS (T-24 FOR NORTH TOWER EVENT CENTER). CHANGE OF CONTRACTOR FROM CUPERTINO ELECTRIC TO DSE ELECTRIC INC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74533	19041-10000-16889	7940 N FAIR AVE	91352	6	189B173   285	2314007028	R1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	05/19/2020 12:00:00 AM	ADDRESS	34.21509	-118.37456	PV1. SYSTEM SIZE OF 5.49 KWDC AND 4.66KWAC WITH (18) MODULES WITH OPTIMIZERS P320, (1) INVERTER 5000H.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74534	15041-20001-05280	6316 N TOPANGA CANYON BLVD #1140-Building B	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM			PC Info Complete	09/10/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	"09/08/2015 Changes to an approved set of plans. Changes include revisions to the lighting fixture schedule, the addition a transformer, and lighting controls. All changes have been reflected onto the Title 24 forms. Changes have been clouded and marked as Delta 9.*****Previous Work Description*****Plan check for power and energy. First time tenant in 2-story retail building (""Jonathan Adler"") part of Westfield Village. Building B. 6,747sqft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74535	19041-20000-52356	1375 N VINE ST BLDG. A-1ST FLR	90028	13	147A187   593	5546016001	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	03/17/2020 12:00:00 AM		Permit Finaled	07/02/2021 12:00:00 AM	ADDRESS	34.09602	-118.32703	Power and lighting for tenant improvement to (E) commercial space.  Plan check for power and energy.  B#19016-10000-28216	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74536	16041-30010-25972	200-300 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	33.94558	-118.4039	08/03/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta ASI-N006. Changes include the addition of new load to existing panels, new panelboards and loads, and a revised lighting floor plan.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74537	15041-10000-12775	2250 S FOX HILLS DR 1-22	90064	5	129B161   138	4315017082	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Public Safety Only			04/28/2015 12:00:00 AM	04/28/2015 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.05144	-118.4154	NEW FIRE WARNING SYSTEM FOR AN APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74538	18041-10000-35650	250 E 1ST ST	90012	14	130-5A213 150	5161016014	[Q]C2-4D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.05038	-118.24114	Fire alarm replacement system for a HIGH RISE BUILDING ; Scope includes (1) new fire alarm system, (7) control panels, (1) communication panel, and (365) fire alarm device.  All exsiting fire alarm devices will be reconnected to the new fire alarm panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74539	12041-10000-25362	20600 W VENTURA BLVD SOUTH BLDG	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			10/23/2012 12:00:00 AM	02/28/2013 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.16715	-118.58204	Chnages to approved set of plans. Scope of work includes build out of lounge in common area of residential building. Approved set of plans have been permitted under application #11041-10000-23452	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74540	18041-10000-36936	2706 E MEDIA CENTER DR Training-Room	90065	1	150B213  3657	5442032005	[Q]M2-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Issued	10/24/2018 12:00:00 AM	ADDRESS	34.10771	-118.24215	TITLE 24 ENERGY ONLY FOR INTERIOR RENOVATION OF EXISTING OFFICE SPACE: CONVERT PORTION OF (E) STORAGE TO TRAINING ROOM.TOTAL AFFECTED AREA 1303 SQ.FT B#18016-10000-13810	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74541	14041-20000-18813	8861 N MONOGRAM AVE	91343	12	195B137   409	2688034009	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM	07/16/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.23182	-118.49284	PV1 SINGLE FAMILY. TOTAL SYSTEM SIZE 3.6. KW AC USING CENTRAL TRANSFORMERLESS INVERTER. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74542	17041-10001-23340	11401 N PORTER RANCH DR BLDG 3	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			09/09/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	05/06/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	CHANGES TO APPROVED SET, CHANGES INCLUDEDS REVISING FEEDER SCEHDULE, UPDATING THE FAULT CURRENT AND VOLTAGE DROP REFLECTING BUILD OUT CONDITION. REVISING DWELLING UNIT PANEL SCHEDULE  FROM A GAS DRYER TO A ELECTRIC DRYER ADDING NEW CKT FOR TRASH COMPACTOR.  SERVICE LOAD CALCULATION HAS BEEN REVISED AS WELL. ALL CHANGES ARE CLOUDED UNDER DELTA 2 ONLY. BLDG 3 OF 10ORGINAL SCOPE:Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 3 of 10.  Type III.       Building permit #17010-10000-02379	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74543	16041-10000-07295	865 S FIGUEROA ST 3150	90017	14	129A207   241	5144022057	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/01/2016 12:00:00 AM	03/01/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.04653	-118.26275	(TI) EXPANSION OF (E) SUITE 3150. PC for energy oly. 1,889 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74544	10041-20000-06470	12765 W VAN NUYS BLVD	91331	7	210B161   139	2533019032	[Q]C2-1VL-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM			Ready to Issue	07/15/2010 12:00:00 AM	ADDRESS	34.27525	-118.41242	Plan check power and energy for a TI of Food 4 Less grocery store.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74545	12041-20000-10803	4108 S DEL REY AVE	90292	11	108B153  1216	4230005040	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			05/10/2012 12:00:00 AM	03/05/2013 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	33.98836	-118.4448	New 77 unit apartment. Plan check for power and energy. 4 story apartment. Equipped with a generator. 106130 conditioned sqft. Fire alarm variance on file.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74546	11041-10000-16751	13730 W ROSCOE BLVD	91402	6	192B157   675	2213021015	[Q]C1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	11/08/2011 12:00:00 AM	ADDRESS	34.22149	-118.43179	REPLACEMENT OF LIGHT FIXTURES FOR AN EXISTING OFFICE BUILDING ON EVERY FLOOR.  NORTH II MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74547	17041-10000-39389	633 W 5TH ST #3700	90071	14	130-5A209 144	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/31/2017 12:00:00 AM	11/22/2017 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.05099	-118.25468	T-24, PC FOR ENERGY ONLY. TENANT INPROVMENT IN (E) OFFICE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10403 SQ. FT. B#17016-20000-30869	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74548	16041-30000-38092	1866 N GLENDALE BLVD	90026	13	144A209   116	5423001020	C1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	Yes	1974.10	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	10/27/2016 12:00:00 AM		Permit Finaled	11/17/2016 12:00:00 AM	ADDRESS	34.08961	-118.25902	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74549	13041-20000-12427	5750 W WILSHIRE BLVD #500	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.06227	-118.3542	RENOVATON OF INTERIOR SPACES IN OFFICE BUILDING FOR NBC UNIVERSAL. WORK DONE IN SUITE 500. CHANGE IN LIGHTING FIXTURES AND EMERGENCY CIRCUIT. PLAN CHECK FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 5900 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74550	12041-10000-21219	5445 N ETHEL AVE	91401	4	174B161   710	2345005041	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM			PC Approved	09/07/2012 12:00:00 AM	ADDRESS	34.16991	-118.41827	7.92 PV roof mounted for a single family.(permite was issued under# 12041-20000-14839)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74551	18041-10000-23876	3201 S HOOVER ST 1845	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	ADDRESS	34.0255	-118.28448	PLAN CHECK FOR POWER AND ENERGY FOR NEW RESTAURANT TENANT IMPROVEMENT OF EXISTING GROUND FLOOR COMMERCIAL SPACE IN EXISTING MIXED-USED BUILDING. TOTAL 47 OCC REPLACE STOREFRONT - TOTAL NEW CONNECTED LOAD APPROX: 130A, TOTAL AFFECTED AREA = 1659 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74552	11041-10000-25153	15237 W COBALT ST	91342	7	225B145   248	2501010010	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/23/2011 12:00:00 AM			Reviewed by Supervisor	12/12/2011 12:00:00 AM	ADDRESS	34.31226	-118.46429	PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74553	15041-10000-05288	2800 E 11TH ST	90023	14	120A221   138	5169007002	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.02241	-118.21816	Energy plan check for a commercial warehouse, replacing HID with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74554	16041-20001-41648	4901 N AZUCENA DR	91364	3	168B101   388	2076006069	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2017 12:00:00 AM			PC Approved	02/14/2017 12:00:00 AM	ADDRESS	34.15715	-118.61473	Revisions to approved set of plans.  Restamp of plans to incorporate changes made to ground mount detail.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74555	12041-20000-16365	6701 S CENTER DR WEST	90045	11	102B165    37	4104001020	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	09/27/2012 12:00:00 AM	ADDRESS	33.97907	-118.39369	T.I. to high rise building on 13th floor in rooms 1313-1318 and 1321-1324.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74556	10041-10000-11498	1099 S GRAND AVE	90015	14	127-5A207 271	5139008001	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM			Corrections Issued	06/30/2010 12:00:00 AM	ADDRESS	34.04179	-118.26214	Core and shell for New 20 story building. New service, Panel board, and circuit. Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74557	09041-10013-08059	6250 W HOLLYWOOD BLVD	90028		148-5A189 132	5546029917	C4-2D-SN		Hollywood	Central Hollywood			Electrical	Electrical	Commercial			04/15/2010 12:00:00 AM			PC Approved	07/07/2010 12:00:00 AM	ADDRESS	34.10133	-118.32547	PLAN REVIEW FOR AS-BUILT SETS OF PLANS FOR A NIGHT CLUB; SUBMITTED SETS OF APPROVED PLANS INCLUDE THE ORIGINAL APPROVED SET AND REVISIONS TO THE ORIGINAL APPROVED SET. CLIENT WILL SUBMIT A DETAIL OF THE CHANGES NOT ADDRESSED BY THE APPROVED SETS OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74558	12041-10001-18998	1318 N NORTH SPRING ST	90012	1	136-5A217  91	5409006051	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			02/22/2013 12:00:00 AM			Corrections Issued	02/27/2013 12:00:00 AM	ADDRESS	34.06632	-118.23289	New rooftop 28kw photovoltaic system for an existing low-rise commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74559	14041-10000-17295	333 S FIGUEROA ST	90071	14	132A209   190	5151011036	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	03/24/2015 12:00:00 AM		Issued	03/24/2015 12:00:00 AM	ADDRESS	34.05436	-118.25543	PLANCHECK FOR T24 ENERGY, TENANT IMPROVEMENT FOR 3RD FLOOR . HIGHRISE. FLOOR CONSISTS OF COMMERICIAL AND HOTEL ROOMS. 2596 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74560	19041-10000-25800	1320 N LAKE SHORE AVE	90026	13	141A209   702	5419031013	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park		1974.20	Electrical	Electrical	Commercial			07/05/2019 12:00:00 AM			PC Approved	07/05/2019 12:00:00 AM	ADDRESS	34.07876	-118.2599	CHANGE OF USE FROM OFFICE TO GYM. T-24 Enery Only. Total Area: 5559 Sqr Ft. Building Permit: 19016-10000-17913	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74561	13041-10000-00982	380 WORLD WAY Space  T31	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	04/22/2013 12:00:00 AM		Permit Finaled	12/21/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 654 SQFT TENANT IMPROVEMENT  FOR USE AS A  FOOD & BEVERAGE  CONCESSION (880 Degrees Neapolitan Pizzeria).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74562	13041-20000-35880	12359 W VENTURA BLVD	91604	2	162B165   189	2367018001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	05/09/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.14306	-118.40283	TI FOR EXISTING RESTAURANT. OCCUPANT LOAD EXCEEDS 100, PLAN CHECK FOR POWER AND ENERGY. T24 SHALL BE PROVIDED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74563	17041-20000-09381	10803 W PENROSE ST	91352	7	195B177   170	2544026023	RA-1	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2017 12:00:00 AM	04/12/2017 12:00:00 AM		Issued	04/12/2017 12:00:00 AM	ADDRESS	34.23246	-118.36526	pv1install roof mounted pv system sized 6kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74564	14041-20000-18205	12844 N CAPE COTTAGE LANE	91342	7	222B161   355	2525025066	R1-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.30352	-118.41914	New roof mounted PV system with Enphase Microinverter, Model M215-60-240.  System size is 5.75KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74565	14041-20000-15489	8150 N RHEA AVE	91335	12	192B121   953	2103003017	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.21876	-118.5414	PV1.  Install 4.59 kW roof-mounted, utility-interactive PV system.  Transformerless inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74566	13041-10000-22748	258 N AMALFI DR	90402	11	123B129   687	4410023020	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.03154	-118.51435	PV1 5.39KWdc 240V XFRMless. 2STORY. nonSTD. ROOFMOUNT.  [( 1) INV: SOLAREDGE SE5000A-US] [( 22) MOD: TRINA {TSM-245PC05.18} with optimizers]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74567	18041-20001-41888	5623 N FAIRHAVEN AVE	91367	3	174B085    93	2046009016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			PC Approved	11/03/2018 12:00:00 AM	ADDRESS	34.17276	-118.6582	Expedite per applicant requestPlan check for PV roof mounted system, system size: 14.52KW DC, 12.342KW AC with 44 PV modules and 44 microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74568	11041-10000-09795	2101 E PACIFIC COAST HWY Main-Substation	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			05/13/2011 12:00:00 AM			PC Info Complete	08/10/2011 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALL APPROX. 1100' OF OVER HEAD 13.8KV LINES FROM THE MAIN SUBSTATION AND CONTINUES WITH APPROX 500' OF SAME 13.8KV LINES IN A CABLE TRAY TO SUBSTATION #10.     <<<<INSTALL A 7.5MVA, 13.8KV:2.4KV STEP DOWN TRANSFORMER IN SUBSTATION #10 FOR TWO CRUDE OIL PUMP MOTORS (250HP & 1,250HP) IN TESORO REFINARY.   11041-10001-0979  >>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74569	18041-20000-07675	4409 N SAUGUS AVE	91403	4	166-5A145 140	2276041017	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			03/02/2018 12:00:00 AM	06/28/2019 12:00:00 AM		Permit Finaled	05/19/2022 12:00:00 AM	ADDRESS	34.15008	-118.46623	New 4-story 12 unit apartment with subterranean garage.  800A 240/120V service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74570	18041-20000-27324	11155 W HUSTON ST	91601	2	168B173   130	2353017009	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Apartment			07/20/2018 12:00:00 AM	10/15/2020 12:00:00 AM		Permit Finaled	03/02/2023 12:00:00 AM	ADDRESS	34.15988	-118.37347	New 4-story 24-unit apartment building over 1-story garage (5 stories total).  800A 208Y/120V 3ph-4w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74571	16041-20001-42774	3886 N CARPENTER AVE	91604	2	162B169   534	2369025007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2016 12:00:00 AM			Reviewed by Supervisor	12/14/2016 12:00:00 AM	ADDRESS	34.14004	-118.3919	EXPEDITE PER APPLICANT.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 10KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74572	15041-20001-04724	18929 W GRANADA CIR	91326	12	216B121   424	2872010035	RE9-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			02/18/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.28659	-118.54566	EXPEDITE PER CUSTOMER REQUEST.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH  MSP.(35) CANADIAN SOLAR 255/235 MODULES(35) SOLAR EDGE OPTIMIZERS P300(1) SOLAR EDGE INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74573	13041-10000-34527	219 W 92ND ST	90003	8	094-5A203 227	6040036006	R2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	04/12/2016 12:00:00 AM	ADDRESS	33.95292	-118.27661	PV1, Install  2.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3000A-US] and (11) modules[TRINA SOLAR # TSM-250PA05.18] on a 1-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74574	12041-10000-22540	7342 N FULTON AVE	91605	2	186B157   361	2327001018	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			Corrections Issued	09/21/2012 12:00:00 AM	ADDRESS	34.20435	-118.42239	New lighting, switches, receptacles for an existing cat shelter.  Load is less than 400 Amps.  PLAN CHECK ONLY for T-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74575	13041-20000-27189	10759 W PICO BLVD	90064	5	126B157   785	4320004091	C2-1VL-O-POD	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			Corrections Issued	10/01/2013 12:00:00 AM	ADDRESS	34.04124	-118.42652	REMODEL OF CURRENT EINSTEIN BROS. PC FOR T24 ENERGY ONLY. NEW LIGHTING. LOAD LESS THAN 400A. OCCUPANT LOAD LESS THAN 100. NOT ASSEMBLY OCCUPANCY PER BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74576	16041-10002-40590	11058 W CHANDLER BLVD	91601	2	171B173  1406	2350014015	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			Verifications in Progress	05/24/2018 12:00:00 AM	ADDRESS	34.168	-118.37216	THIS SUPP. IS TO COLLECT ADDITIONAL HOURS FOR THE SCOPE ON SUPP. 10001PERMIT TO BE COLLECTED UNDER THIS SUPP. Supplemental PC for changes to approved set.Changes include new lights, receptacales, panels, equipment  removal of fire pump, addition of electrical room and addition of transformer disconnects. All changes clouded under delta 1,2,3,4,5.This is plan check only! Permit for scope to be collected under 10002	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74577	19041-20000-35438	255 N HOMEWOOD ROAD	90049	11	132B141    44	4403002004	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2019 12:00:00 AM			PC Approved	11/19/2020 12:00:00 AM	ADDRESS	34.06174	-118.48253	600A 240/120V 1ph-3w service, distribution, power and lighting for new construction.  Plan check for power only - electrical permit fees issued under building combination permit 19010-30000-00979.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74578	18041-20000-33756	3609 N DIXIE CANYON AVE	91423	4	162B157   682	2386009027	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM	09/04/2018 12:00:00 AM		Permit Finaled	09/11/2018 12:00:00 AM	ADDRESS	34.13964	-118.42657	PV1.  Install 12.6 kW roof mounted grid tied PV system.  (42) modules with microinverters.Derating of main breaker to 150A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74579	16041-10002-43558	10250 W SANTA MONICA BLVD UNIT 1780	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/05/2017 12:00:00 AM			PC Approved	04/05/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	[This is plan check only] Revision to approved set noted under delta-7: Remove recessed puck light by the cashwrap; Indicates the current limiter amp. rating associated with ckt L-11,13; Revise T-24 form LTI-01 for installed lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74580	15041-20000-35221	9019 N SYLMAR AVE	91402	6	195B149   109	2639012007	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Expired	11/20/2017 12:00:00 AM	ADDRESS	34.23374	-118.44602	PV1 SFD TOTAL SYSTEM SIZE 7.6KW AC USING CENTRA INVERTER SYSTEM. TOTAL OF 34 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74581	18041-10000-05368	5132 N COMERCIO AVE	91364	3	171B105   951	2167006013	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2018 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	34.16258	-118.59625	PC for 7.6kW(ac) Solar PV for SFD. Installing 30 modules (8.7kW (DC)) and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74582	12041-10000-01058	1800 S AVENUE OF THE STARS 14th floor	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/17/2012 12:00:00 AM			PC Approved	01/17/2012 12:00:00 AM	ADDRESS	34.06095	-118.41786	Ti in the restroom areas. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74583	10041-10000-17098	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM			PC Approved	08/30/2010 12:00:00 AM	ADDRESS	34.20696	-118.3417	RELOCATE  LIGHTS. Plan check for T24. ( Permit was pulled # 10041-10000-15955)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74584	14041-20001-00506	17247 W INDEX ST	91344	12	210B133    57	2697014024	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.27581	-118.50936	((Expedite Fees))PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZER. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74585	13041-10001-29498	12867 W HAMMOCK LANE	90094	11	102B157   397	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	10/29/2013 12:00:00 AM	ADDRESS	33.9749	-118.41979	EXPEDITED PLAN CHCK PER  APPLICANT REQUEST.((((PV1, Installing roof-mounted solar array, interconnet with main panel. System size: 4 KW DC.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74586	14041-10000-34513	6467 N LANKERSHIM BLVD	91606	2	180B169   896	2322017071	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/12/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	34.18847	-118.38798	T24, REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 5560 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74587	16041-10000-05417	8715 S CROCKER ST	90003	9	096A205    45	6041017005	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			02/16/2016 12:00:00 AM			Reviewed by Supervisor	03/01/2016 12:00:00 AM	ADDRESS	33.95863	-118.26822	800 AMP SERVICE UPGRADE AND NEW DISTRIBUTION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74588	17041-10000-10421	2800 S VIA CABRILLO MARINA	90731	15	006B201     3	7440041906	A1-1, M2, R1, R4, [Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	01/12/2023 12:00:00 AM	ADDRESS	33.71786	-118.28267	Plan check for Titel 24 only in existing space. Remove metal halide fixture and replace with new LED fixtures. Total area: 201,275 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74589	14041-20000-16630	7470 N FIGUEROA ST 1st floor	90041	14	162A231    31	5709001014	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	01/13/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.13993	-118.18696	Plan check for energy only. New lighting (incl. emergency) on first floor of 3-story commercial building. Tenant is LA Firemen's Relief Association.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74590	19041-20002-12478	12147 W VENTURA BLVD	91604	2	162B165    22	2367016008	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.01	Electrical	Electrical	Commercial			09/13/2019 12:00:00 AM			PC Approved	09/13/2019 12:00:00 AM	ADDRESS	34.14356	-118.39685	09-13-2019 Changes to an approved set of plan, changes include reduce load on panel schedule and remove receptacle on floor plan. All Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74591	18041-10000-20411	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	11/30/2018 12:00:00 AM	ADDRESS	34.01366	-118.28294	Energy plan check for a restroom building, Scope include new lighting and receptacle.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74592	14041-20000-22040	12050 W VENTURA BLVD C105	91604	2	162B165   141	2369015019	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			08/14/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	10/21/2014 12:00:00 AM	ADDRESS	34.14349	-118.39426	Plan check for title 24 on a T.I  yogurt shop. Total working area is 1275 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74593	10041-10000-13540	725 S FIGUEROA ST # 725	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/14/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	TI IN AN EXISTING OFFICE. PLAN CHECK FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74594	18041-10000-03062	13730 W FOOTHILL BLVD	91342	7	222B153    30	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			01/26/2018 12:00:00 AM	01/26/2018 12:00:00 AM		Issued	01/26/2018 12:00:00 AM	ADDRESS	34.30887	-118.43253	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74595	14041-20000-04058	6913 N RUBIO AVE	91406	6	183B137   344	2225007009	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2014 12:00:00 AM	05/16/2014 12:00:00 AM		Permit Finaled	06/18/2014 12:00:00 AM	ADDRESS	34.19605	-118.49588	Roof mounted PV system with 12.25 KWdc.  Install new 125A PV subpanel.Note: Permit fee is $0.00 due to Senate Bill 1222 from 2012.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74596	14041-20000-24184	19543 W SAN JOSE ST	91326	12	207B117   435	2708005020	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2014 12:00:00 AM	09/17/2014 12:00:00 AM		Permit Finaled	09/29/2014 12:00:00 AM	ADDRESS	34.26073	-118.55921	$0 permit fee is due to Senate Bill SB-1222.  PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 1.2KW INTERCONNECTED WITH MSP.(50) KYOCERA KD255 MODULES(50) POWER OPTIMIZERS P300(2) SOLAR EDGE SE6000 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74597	18041-10000-42828	3220 W LOS FELIZ BLVD	90039	13	156A205    49	5435036021	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			11/07/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Issued	11/08/2018 12:00:00 AM	ADDRESS	34.12305	-118.26892	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74598	18041-10000-34521	9034 N BURNET AVE	91343	7	195B145    46	2654006028	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.2348	-118.46302	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 54.0KWdc / 43.2KWac (150)MODULES- JINKO SOLAR JKM360M-72-V(75) OPTIMIZERS-SOLAREDGE P730 (1)INVERTER-SOLAREDGE SE43.2KUS.PERMIT FEE 1S 0 $ IN ACCORDANCE WITH AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74599	12041-10000-03824	850 E 111TH PL	90059	15	088-5A209 241	6071022006	M1-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2409.00	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Expired	05/27/2014 12:00:00 AM	ADDRESS	33.93557	-118.25914	New service & panels for a trash maitenance yard in a non hazardous general area.   EPC is for power. (no new lighting)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74600	16041-20000-40256	432 S HARVARD BLVD	90020	10	135B193   546	5503010023	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.06623	-118.30392	"""0$ permit fees due to senate bill 1222 ""Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 31.7kW (6kW*4+7.7kW) ungrounded system. (116) 340W pv modules."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74601	14041-20000-10697	11931 W GOSHEN AVE 1-9	90049	11	129B145   830	4265012047	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Apartment			04/23/2014 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.04726	-118.46571	(N) 4-story 9-unit apartment building and one garage level.  800A 120/240V 3ph-4w service.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74602	11041-20000-14877	4157-4163 W BEVERLY BLVD	90004	13	138B197   320	5520025005	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20, 2112.00	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.07642	-118.29977	Plan check for new 800A service upgrade and new panels to existing commercial building. All loads will be on Phase 2 submittal	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74603	18041-20001-06390	22030 W GILMORE ST	91303	3	180B101   726	2139003016	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2018 12:00:00 AM			PC Approved	03/05/2018 12:00:00 AM	ADDRESS	34.18741	-118.60727	Revisions to approved set.  Change of solar panel module model and reduction in total number of modules from (14) to (13).  (((Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (14) modules. PV system is being interconnected onto a center-fed panel.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74604	14041-20000-17476	13277 W VAN NUYS BLVD #100	91331	7	207B157   342	2619017030	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.26583	-118.42276	Plan check for power and energy. Remodel of dental office in existing single story building. New lighting and loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74605	15041-10000-39609	11835 W OLYMPIC BLVD STE 140E	90025	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			11/23/2015 12:00:00 AM	11/23/2015 12:00:00 AM		Permit Finaled	12/30/2015 12:00:00 AM	PIN	34.03318579	-118.45141815	Energy plan check for an office T.I located in the 1st floor of a high rise building; Scope includes new lighting and receptacles. Total area is 3846-SQ feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74606	19041-20000-33373	14022 N ARLEE PL	91342	7	231B157   232	2582015001	RS-1	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2019 12:00:00 AM	08/23/2019 12:00:00 AM		Permit Finaled	02/04/2020 12:00:00 AM	ADDRESS	34.32723	-118.42324	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM TO EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK CONSISTS OF (1) BATTERY AND A PANEL. SYSTEM SIZE IS 13.2 KWH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74607	16041-10001-25482	8601 S LINCOLN BLVD #180	90045	11	096B157   624	4119026043	[Q]RAS4-1-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM			PC Approved	02/13/2017 12:00:00 AM	ADDRESS	33.95939	-118.41943	Plan check for Title 24 only in existing space T.I. UPS store. Total area: 1,176 sq ft.Note: Permit was pulled under 16041-10000-25482	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74608	10041-20000-10528	21441 W OSBORNE ST UNIT C & D	91304	12	195B105    38	2779018035	MR2-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/03/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	08/12/2010 12:00:00 AM	ADDRESS	34.23378	-118.599	PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR CHANGE OF USE FROM MANUFACTURING TO PHARMACEUTICAL LAB AND TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74609	18041-10001-35565	1255 S ELDEN AVE	90006	1	129B197  1063	5076018023	C2-1	Central	Wilshire	Pico Union		2134.02	Electrical	Electrical	Apartment			10/15/2019 12:00:00 AM			PC Approved	10/15/2019 12:00:00 AM	ADDRESS	34.04755	-118.28789	"DELTA ""3""CHANGES TO APPROVED SET. CHANGING RESIDENTIAL DISTRIBUTION BOARD RATING TO 1200A AND ADDRESSING ATS2 FOR ELEVATORS  AS ""LEGALLY REQUIRED STANDBY SYSTEMS"". NO NEW ADDED LOADS. NO OTHER CHANGES APPROVED. PLAN CHECK ONLY.<<<Full plan check for a 7-story, 90-unit apartment building (AFFORDABLE HOUSING)  with a 2500-Amp 120/208v  3-phase service.>>>"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74610	13041-20000-24718	17904 W MONTAGUE CT PV-1	91344	12	219B125    19	2601063016	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.29849	-118.52522	"INSTALLATION OF  GROUD MOUNTED PV SOLAR SYSTEM.  Building plans have already been approved.  System is Ungrounded and uses ""Power Optimizers"".  Plan Check only, Permit has already been pulled. (ORINGAL PERMIT #13041-10000-20692))))"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74611	17041-10000-45929	7269 W MELROSE AVE	90046	5	141B181   540	5525012014	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			01/22/2018 12:00:00 AM			Reviewed by Supervisor	01/30/2018 12:00:00 AM	ADDRESS	34.08365	-118.34812	CHANGE OF USE FROM A SPA TO AN OFFICENEW SERVICE AND PANELS AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74612	15041-20000-40831	1501 W 59TH PL	90047	8	105B193   227	6002010019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	33.98682	-118.30255	Plan check for PV roof monted system. System size: 5.0 kW with 19 modules 1 inverter(5.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74613	13041-10000-33104	19511 W TRIBUNE ST	91326	12	207B117    77	2708006006	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/27/2014 12:00:00 AM	ADDRESS	34.26689	-118.55788	PV1, Install 7.5 kw DC roof-mounted solar array, interconnect with the service panel.(1)Transformerless inverter(s):Solaredge SE6000A-US. (30) modules Hanwha HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74614	17041-10000-26060	21615 W PLUMMER ST 2ND FLR	91311	12	201B105   245	2746015014	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Expired	10/20/2017 12:00:00 AM	ADDRESS	34.24286	-118.60121	PC FOR OFFICE TI IN COMM. BLDG. ON THE 2ND FLOOR FOR TITLE 24 ENERGY ONLY. TOTAL 1760 SQ.FT. INSTALLING NEW LIGHTS AND RECEPTACLES. NEW PANEL ( NOT PART OF TITLE 24 )TO BE INCLUDED IN THE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74615	15041-10000-27732	8855 N REMICK AVE	91352	6	195B165   413	2634009003	RA-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			08/24/2015 12:00:00 AM	08/24/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.23045	-118.4052	PV1, roof mounted solar array. 10.6 kW PV system.(40) modules: #KU2656ZPA(1) inverter: FRONIUS # Primo 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74616	11041-20000-11780	20425 W SORRENTO LANE Building-15	91326	12	213B113   326	2701003034	[T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Public Safety Only			06/08/2011 12:00:00 AM	06/08/2011 12:00:00 AM		Permit Finaled	04/18/2012 12:00:00 AM				Plan check for new fire system installed in apartment building 15.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74617	12041-10000-16210	2401 W 6TH ST	90057	1	133-5A203  68	5154038022	C2-2	Central	Westlake			2088.02	Electrical	Electrical	Commercial			07/13/2012 12:00:00 AM			PC Approved	07/13/2012 12:00:00 AM	ADDRESS	34.0611	-118.27802	Adding battery backups to an existing office space in a low-rise building.  PLAN CHECK ONLY for Emergency Lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74618	18041-20000-00743	1302 S LA BREA AVE	90019	10	129B181   660	5070001036	C2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM	01/09/2018 12:00:00 AM		Permit Finaled	12/30/2019 12:00:00 AM	ADDRESS	34.04983	-118.34395	Plan check for a fire alarm system for a new commercial building. System consists of (1) FACP and (78) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74619	19041-20000-48594	6652 N MAMMOTH AVE	91405	2	180B157   315	2238011048	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1281.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	11/25/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	34.19167	-118.43224	PV1.  Install 12.675 kW DC roof mounted PV system.  (39) modules with 11.4 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74620	16041-10000-45093	2202 S VERMONT AVE	90007	8	123B197   235	5055001040	C2-1VL-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2217.10	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	02/27/2017 12:00:00 AM	ADDRESS	34.03576	-118.29137	PC for energy only. Remove HID fixture and replace with new LED fixtures. Area: 7,150.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74621	17041-20002-30155	7943 N WOODLEY AVE	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			05/09/2018 12:00:00 AM			PC Approved	05/09/2018 12:00:00 AM	ADDRESS	34.21559	-118.48387	05/09/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. A 400 Amp distribution board has been removed.4/30/2018 Changes to an approved set of plans.  changes noted delta 1 and delta 2.  changes include different inverters and interconnections.  (7) new inverters, (3) 33.3kw and (4) 20kw. No change in system output 180kw.*****Previous Work Description*****((((Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size 960 kWac. Ground-mounted portion of the system is 180 kWac and consists of (3) inverters, (512) modules, and (1) load center.Note: Roof-mounted portion of the system has application number 17041-20000-30147.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74622	17041-10001-46453	10538 W EDGELEY PL	90024	5	135B153    65	4360021048	R1-1	West Los Angeles	Westwood	Westwood		2652.01	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2017 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.06932	-118.4366	expedite per applicant requestNEW ROOFTOP SOLAR SYSTEM WHICH CONSIST OF 26 SOLAR MODULES (LG ELECTRONICS LG335N1C-A5) WITH MICRO-INVERTERS (ENPHASE IQ6PLUS-72-2-US).  SYSTEM SIZE IS 8.71KWdc and 7.28KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74623	14041-10000-29603	12490 W FIELDING CIR	90094	11	102B161  1250	4211034031	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			10/24/2014 12:00:00 AM	11/19/2014 12:00:00 AM		Permit Finaled	12/23/2016 12:00:00 AM	ADDRESS	33.9788	-118.41237	Plan check for Temp power supply by 1,000KW Generator for construction. Equipment include 1600 amp service and 5 Transformers 75KVA and 42 spider box 5 panels circuit breakers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74624	15041-10001-18508	4813 W OAKWOOD AVE 1-18	90004	4	138B193   209	5522030010	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			07/05/2017 12:00:00 AM			PC Approved	07/05/2017 12:00:00 AM	ADDRESS	34.07741	-118.31188	Changes to approved set.  Remove main disconnect switch.  Separate pull box for future underground service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74625	18041-20000-33972	16438 W VANOWEN ST	91406	6	180B137    28	2231006050	C2-1VL-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			09/05/2018 12:00:00 AM	09/05/2018 12:00:00 AM		Issued	09/05/2018 12:00:00 AM	ADDRESS	34.1937	-118.49152	800 amp service equipment replacement to consolidate five meters into one, no change in service rating. plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74626	11041-20000-07639	13480 W MAXELLA AVE 1st to-5th floor	90292	11	105B153    77	4212004032	[T][Q]RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/15/2011 12:00:00 AM	04/15/2011 12:00:00 AM		Permit Finaled	05/22/2012 12:00:00 AM	ADDRESS	33.98522	-118.44179	T.I. to existing high rise building.  Install general/emergency lighting in corridor of 1st, 2nd, 3rd, 4th, and 5th floors, and exercise room of 1st floor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74627	17041-10000-30429	1531 S OCEAN FRONT WALK	90291	11	106-5A143 134	4226001900	OS-1XL-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	PIN	33.98528361	-118.47258903	PC FOR POWER ONLY FOR SERVICE UPGRADE FOR A CAMLOCK OUTLET FOR VENDORS. 1200A @ 208V	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74628	10041-10000-03410	12015 E WATERFRONT DR	90094	11	105B165   916	4211011032	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			02/25/2010 12:00:00 AM	03/30/2010 12:00:00 AM		Permit Finaled	10/04/2010 12:00:00 AM	PIN	33.9832223	-118.40406817	New work in an existing4 STORY OFFICE  BLDG  in PLAYA VISTA, METHANE AREA.  Plan check for  POWER , LIGHTING , ENERGY. the service and various distribution boards are EXISTING or within the scop of others. ((((((((((((((((((((( APPLICANT MISS CALCULATED THE FEES AND BROUGHT A CHECK FOR AMOUNT OF $7099.92 SO  WE  REDUCED THE NUMBER OF BRANCH CKTS FROM 295 TO 155. THE REST WILL BE SUBMITED IN SUBMITAL 2.)))))))))))))))))))))))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74629	18041-10000-37710	802 S BROADWAY	90014	14	127-5A209 143	5144016067	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	10/08/2019 12:00:00 AM		Permit Finaled	04/19/2021 12:00:00 AM	ADDRESS	34.04355	-118.25466	FULL PLAN CHECK FOR POWER AND ENERGY FOR - CHANGE OF USE FROM THEATER TO RETAIL.TENANT IMPROVMENT FOR A NEW RETAIL STORE. SCOPE INCLUDES NEW DISTRIBUTION PANELS, CIRCUITS AND LIGHTING - TOTAL AFFECTED AREA = 29418 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74630	14041-20001-12484	10930 N BELMAR AVE	91326	12	210B117   295	2708007005	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2014 12:00:00 AM			PC Approved	05/19/2014 12:00:00 AM	ADDRESS	34.2689	-118.55773	Fee for expedite only.*****Roof mounted PV system, with system size 10.71KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74631	17041-20000-20126	18936 W BESSEMER ST	91335	3	177B121   564	2128014013	R1-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	08/11/2017 12:00:00 AM	ADDRESS	34.18076	-118.54622	Plan check for solar pv system, roof-mounted on SFD.10.4kW ungrounded system. (30) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74632	18041-10001-11737	200 N ROCKINGHAM AVE	90049	11	132B137   293	4406008006	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2623.03	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2018 12:00:00 AM			PC Approved	06/05/2018 12:00:00 AM	ADDRESS	34.05882	-118.49112	EXPEDITE PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 36KWdc / 28KWac.(100)MODULES-LG LG360Q1C-A5(100)MICROINVERTERS-IQPLUS-72-X-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74633	17041-10000-10508	9550 N DONNA AVE	91324	12	201B121   689	2762033033	RE11-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.24446	-118.54735	PC FOR PV SYSTEM ROOG MOUNTED - SYSTEM IS 11.4KW AC USING CENTRAL INVERTER SYSTEM AND TOTAL OF 45 MODULES. SYSTEM USES POWER OPTIMIZERS.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74634	12041-10000-12285	421 N HENRY FORD AVE	90744	15	030B213   392	7440001***	M3, M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			05/31/2012 12:00:00 AM	08/16/2012 12:00:00 AM		Permit Finaled	01/23/2014 12:00:00 AM	ADDRESS	33.77533	-118.24134	Plan check for new 1000KVA medium voltage transformer, MCC, and feeders (VFDs & xfrmers)  for new oil well. Motors for oil well on seperate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74635	14041-10000-20915	1010 S GLENDON AVE	90024	5	132B153  1096	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/02/2014 12:00:00 AM	ADDRESS	34.06207	-118.44398	T24 for remodeling  an existing resturant. Total area 1434 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74636	15041-20000-14030	13291 N RALSTON AVE	91342	7	225B141   166	2501002023	M1-1, P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			05/08/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Closed	01/11/2017 12:00:00 AM	ADDRESS	34.31344	-118.47393	Plan check for power only. Project site is an existing commercial building. Project scope is the installation of a 4000-amp main service board with (4) sections, (1) 1600-amp distribution board, and (1) 900 kVA generator. Loads on the main service board are all future.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74637	18041-10000-00115	3970 N VERDUGO ROAD	90065	14	156A217   100	5459014020	[Q]C1.5-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1861.00	Electrical	Electrical	Commercial			01/02/2018 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.12268	-118.23079	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74638	14041-20000-20873	19611 W RUNNYMEDE ST	91335	3	186B117   447	2116006104	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2014 12:00:00 AM	08/04/2014 12:00:00 AM		Permit Finaled	09/03/2014 12:00:00 AM	ADDRESS	34.20607	-118.56051	Standard Plan. 3.5KW PV1 roof-mounted system including: (13) Solarworld SW275 modules and Enphase M250 microinverters .	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74639	19041-20000-30156	13356 W CUMPSTON ST	91401	4	174B157  1060	2344011017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM	ADDRESS	34.16939	-118.42437	Plan check for PV roof mounted system, System size: 10.89 KW DC, 10.395KW AC with 33 PV Modules and 33 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74640	17041-10000-44207	5540 W CENTURY BLVD	90045	11	090B173   130	4129029015	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	33.94512	-118.37722	PC for energy only, Outdoor Title-24.  Removing HID fixtures and replacing with New LED. area: 23850	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74641	16041-10000-29544	990 W 190TH ST Suite 440	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/19/2016 12:00:00 AM		Permit Finaled	01/12/2018 12:00:00 AM	ADDRESS	33.85813	-118.29505	TITLE 24 PLAN CHECK ONLY.  TENANT IMPROVEMENT (4,573SF) TO EXISTING OFFICE SPACE. NEW LIGHTING AND RECEPTACLES.  NO CHANGE OF USE, NO CHANGE TO EXTERIOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74642	11041-10001-12953	525 E ANAHEIM ST	90744	15	030B209     7	7423023004	[Q]M2-1VL-O, [Q]RD3-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	10/14/2011 12:00:00 AM		Permit Expired	11/12/2013 12:00:00 AM	ADDRESS	33.78047	-118.25663	MODIFICATION TO PREVIOUSLY APPROVED SET OF PLANS.  CHANGE TO FEEDERS ONLY ON PAGE E3.  NON-CLASSIFIED AREA.  <<<<<OIL PRODUCTION SITE:  INSTALLATION OF CIRCUIT BREAKERS, TRANSFORMERS, CABLE TRAYS & OTHER ANCILLIARY, AND RE-ROUTING AND REWIRING OF CABLES.>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74643	10041-20000-21897	11990 W VENTURA BLVD	91604	2	162B165   132	2369015016	(Q)C2-1VL, (Q)P-1VL, C2-1VL, P-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/02/2010 12:00:00 AM	11/02/2010 12:00:00 AM		Permit Finaled	01/25/2011 12:00:00 AM	ADDRESS	34.14351	-118.39333	T.I. to existing building.  Install general lighting in the main lobby.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74644	18041-20000-36012	19228 W VENTURA BLVD	91356	3	174B117   358	2163017022	C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	Commercial			09/20/2018 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.17244	-118.55221	Change of use from retail to medical office.  Critical care and general care patient areas.  Plan check for power and energy. Building application number 18016-20000-30025.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74645	10041-10000-00762	834 S BROADWAY concession-kitchen	90014	14	127-5A209 189	5144016061	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM			PC Approved	01/14/2010 12:00:00 AM	ADDRESS	34.04284	-118.25532	adding walls to create enclosed areas as part of the kitchen at the Orpheum  theater lobbypermit obtained on another applicationplan chkis for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74646	16041-10000-41846	1120 W 6TH ST Suite 103	90017	1	132A207   301	5143024017	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	02/12/2018 12:00:00 AM	ADDRESS	34.05418	-118.26297	FULL PLAN CHECK FOR A CHANGE OF USE FROM RETAIL TO GROCERY MARKET ON PROPOSED CORE AND SHELL SPACE. SCOPE INCLUDES A NEW 800-AMP BOARD, AND ALL NEW ELECTRICAL EQUIPMENT CONNECTING TO AN EXISTING 3000-AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74647	19041-20000-52658	411 S HAMEL ROAD	90048	5	138B169   784	4334015010	R3-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Apartment			12/19/2019 12:00:00 AM	03/04/2020 12:00:00 AM		Permit Finaled	06/03/2022 12:00:00 AM	ADDRESS	34.0716	-118.38189	FIRE ALARM PLAN CHECK, SCOPE OF WORK CONSISTS OF 1 FA PANEL, AND 234 FA DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74648	18041-10000-12415	7624 W FOOTHILL BLVD	91042	7	204A197   122	2558034029	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			04/05/2018 12:00:00 AM	04/06/2018 12:00:00 AM		Issued	04/06/2018 12:00:00 AM	ADDRESS	34.25511	-118.29881	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74649	16041-10000-19265	767 N HILL ST 1ST FLOOR	90012	1	135A215   327	5408019061	C2-2D	Central	Central City North	Historic Cultural		2071.02	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.06256	-118.23987	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE ON THE GROUND FLOOR. TOTAL AFFECTED AREA IS 3551 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74650	15041-20001-23730	6416 N WYSTONE AVE	91335	3	180B121   487	2128004065	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2015 12:00:00 AM			PC Approved	08/07/2015 12:00:00 AM	ADDRESS	34.18725	-118.5473	Expedite per applicant request[[[[[Plan check for PV roof mounted system. System size: 11kW with 36 modules and 2 inverters(6.0kW and 5.0kW, Power-One)]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74651	10041-10000-01030	1500 W FRANCISCO ST	90501	15	057B193    27	7351021039	M3-1, PF-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/20/2010 12:00:00 AM			PC Info Complete	08/01/2011 12:00:00 AM	ADDRESS	33.84954	-118.30384	REMODEL OFFICES, PLAN CHK IS FOR TITLE 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74652	14041-20000-02148	703 W 123RD ST	90044	15	081B197    19	6117007022	R1-1-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.10	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Expired	05/01/2015 12:00:00 AM	ADDRESS	33.92124	-118.28727	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74653	14041-10000-28862	1635 N CAHUENGA BLVD	90028	13	148-5A187 221	5546007028	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM			PC Approved	10/17/2014 12:00:00 AM	ADDRESS	34.10071	-118.32971	PC FOR T24 ENERGY ONLY. TI FOR A OFFICE .TOTAL AREA 2152 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74654	18041-10000-35918	14500 W ROSCOE BLVD 5TH & 6TH-FLOORS	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.22136	-118.44937	TI to (E) commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74655	16041-10000-36289	747 N LILLIAN WAY	90038	13	141B185   328	5533032022	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			10/13/2016 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	12/16/2019 12:00:00 AM	ADDRESS	34.08482	-118.32797	Full Plan check for a new 8 unit (4 story) apartment building. Installing a new service rated at 600 A 120/240V 3phase 4 wire. All new equipment, 2 typical panels plus house panel. Total sqft = 5345.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74656	15041-20000-36392	6605 S ST ANDREWS PL	90047	8	102B193   336	6016017015	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2015 12:00:00 AM	10/30/2015 12:00:00 AM		Permit Finaled	11/18/2015 12:00:00 AM	PIN	33.97887456	-118.3113605	Plan check for PV roof mounted system. System size: 3.0kW and 12 modules and 12 microinverters. Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74657	12041-20000-27919	1726 W 7TH ST 1726-1730	90017	1	132A205   302	5142014001	C2-2	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	12/27/2012 12:00:00 AM		Permit Finaled	09/05/2013 12:00:00 AM	ADDRESS	34.05462	-118.27309	"New 800 amp service for an existing ""strip mall"", new circuits, new subpanels, and lighting in the cooridoors and restrooms.  Full Plan check."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74658	17041-20000-02242	7033 N ETON AVE	91303	3	183B105   552	2138015045	[Q]MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.19832	-118.59559	Plan check for Title 24 only. Project site is a new metal storage building. Project scope is new power and indoor lighting. Total lighting area = 1,775 sq. ft.Note: Building permit has been pulled under 16010-20000-00659	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74659	10041-10000-00468	8700 W BEVERLY BLVD 9th floor	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM	08/24/2010 12:00:00 AM		Permit Finaled	11/10/2010 12:00:00 AM	ADDRESS	34.07666	-118.3805	Remodel the 9th floor tenant space for Cedar-Sinai Medical Center.  Install some new panels, circuits, x-ray equipments, and general/emergency lightings.  Plan check for  power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74660	16041-10002-34971	607 S PARK VIEW ST	90057	1	133-5A203 105	5141005007	C2-2	Central	Westlake	MacArthur Park		2088.02	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	34.06086	-118.27891	CHANGES TO APPROVED SET UNDER DELTA 3.SCOPE INCLUDES CHANGES TO CONDUCTOR SIZING FOR FIRE PUMP.  REVISION TO VOLTAGE DROP CALCS TO REFLECT THE CHANGES.  THIS IS PLAN CHECK ONLY!!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74661	16041-10000-01879	617 W 7TH ST	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/19/2016 12:00:00 AM			PC Approved	01/25/2016 12:00:00 AM	ADDRESS	34.04779	-118.2571	PLAN CHECK FOR ENERGY ONLY FOR OFFICE TI PART OF A HIGHRISE BUILDING. THIS PLAN CHECK COVERS SUITES 300, 301, 302, AND 304. FOUR SEPERATE PERMITS HAVE BEEN ALREADY PULLED UNDER SEPERATE APPLICATIONS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74662	12041-10000-03447	1031 W 34TH ST	90089	8	120B197   677	5039002031	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			02/16/2012 12:00:00 AM	04/24/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	PIN	34.02400284	-118.2895744	INTERIOR BUILD-OUT OF STUDENT HEALTH CENTERSCOPE OF WORK ON 11041-10000-13022 :99,000 sqft USC Student Health building.  Applicant wants plan check for shell only.  Building is 5 story above grade and 1 basement level.  Title 24 includes stairways and outdoor lighting only.   Regular plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74663	13041-10000-23863	11601 W WILSHIRE BLVD SUITE 101	90049	11	129B145   297	4265001038	PB-1, [Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			08/30/2013 12:00:00 AM			PC Approved	09/16/2013 12:00:00 AM	PIN	34.0509267	-118.45996763	Office TI in highrise building.  Newly connected load < 400 A, Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74664	17041-10000-25916	22801 W ROSCOE BLVD LAB BLDG	91304	12	192B097   578	2005002013	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			07/31/2017 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.22014	-118.62547	PC FOR FA IN  COMMERICAL BUILDING.TOTAL COUNT OF DEVICES 177 TOTAL COUNT O PANELS 5	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74665	19041-10000-20325	550 S HOPE ST 27TH FLR	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/29/2019 12:00:00 AM			PC Info Complete	05/29/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	T-24 PLAN CHECK FOR A TI TO AN EXISTING OFFICE SPACE IN A HIGH RISE (27TH FLOOR). SCOPE INCLUDES NEW LIGHTING, CONTROLS AND RECEPTACLES. TOTAL AFFECTED AREA IS 10,643 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74666	16041-20000-25364	5617 N KLUMP AVE	91601	2	174B173   878	2337034016	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.04	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	10/24/2019 12:00:00 AM		Issued	10/24/2019 12:00:00 AM	ADDRESS	34.17274	-118.37534	Plan check for New appartment Building 3 story 10 units with 600A Service. Total area: 2388 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74667	18041-10000-18944	6833 N FALLBROOK AVE	91307	12	183B097   743	2026008043	(Q)RD2-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/01/2018 12:00:00 AM	ADDRESS	34.19448	-118.62378	REPLACE OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74668	14041-10004-17121	1100 S BROADWAY	90015	14	126A209   164	5139017001	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			PC Info Complete	04/24/2019 12:00:00 AM	ADDRESS	34.03941	-118.25893	CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE ADDING NEW 400 AMP PANEL WITH NEW CONNECTED LOAD, CHANGES TO EQUIPMENT LOCATION AND MODIFICATION OF LIGHTING SYSTEM. LOAD CALCULATIONS HAVE BEEN MODIFIED - ALL CHANGES CLOUDED UNDER DELTA 27 & 34	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74669	18041-20001-34311	13756 W ROSCOE BLVD	91402	6	192B153   773	2213016003	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	34.2215	-118.43309	PLAN CHECK ONLY. SUPPLEMENTAL FOR CHANGES TO APPROVED SET. ADDITION OF EXISTING RESTROOM AREA TO SCOPE OF WORK, CHANGE TO LIGHT MODULES FROM 2X4 TO RECESSED, AND CHANGES TO T24 SHEET CALCULATIONS.*ORIGINAL*Plan check for Title 24 only in existing space, T.I. Ice Cream Shop. Total area: 584 sq ft. B#18016-10000-09826	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74670	11041-20000-06314	17777 W VENTURA BLVD # 240	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	TI Unit # 240	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74671	10041-20000-02730	12800 W CHANDLER BLVD	91607	5	171B161   133	2346021049	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			02/17/2010 12:00:00 AM	03/08/2010 12:00:00 AM		Permit Finaled	03/22/2010 12:00:00 AM	ADDRESS	34.16818	-118.41161	Parking lot lightingEnergy	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74672	10041-20000-05319	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/24/2010 12:00:00 AM	09/26/2011 12:00:00 AM		Permit Finaled	12/20/2013 12:00:00 AM	ADDRESS	34.10137	-118.34182	new 5000A sevice; reconnect all existing switchboards	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74673	17041-20001-08826	15701 W LASSEN ST	91343	12	201B141   178	2661029001	RA-1	North Valley	Granada Hills - Knollwood	North Hills West		1098.00	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2017 12:00:00 AM			PC Approved	04/11/2017 12:00:00 AM	ADDRESS	34.25025	-118.47425	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size 7 kWac and consists of (28) modules, (28) micro-inverters, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74674	15041-10000-15179	409 N HAYWORTH AVE	90048	5	138B177    35	5527032025	R3-1	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Apartment			05/18/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	12/02/2016 12:00:00 AM	ADDRESS	34.0785	-118.36277	new 33-units apartment bldg	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74675	19041-10000-43217	6301 W 77TH PL	90045	11	099B165    34	4109002011	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	33.97126	-118.39643	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 21 MODULES ( SUNPOWER A400 AC). SYSTEM SIZE IS 8.4KWdc AND 7.69KWac. PANEL UPGRADE TO 200A SHALL BE PERMITED SEPERATELY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74676	18041-20000-45569	801 E 4TH PL	90013	14	127-5A215  94	5163013009	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/30/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	09/20/2019 12:00:00 AM	ADDRESS	34.04459	-118.23646	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to a portion of the 2nd floor. Total lighting area = 344 sq. ft.Note: Building permit has been issued under 18016-10000-24894	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74677	18041-10000-06265	1030 N SWARTHMORE AVE 2-111	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC for power and energy for retail first time tenant. Installing new panel, lights, receptacles and equipment. Total 580sqft. B# 18016-10000-05243.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74678	16041-20001-41120	120 S GRANVILLE AVE	90049	11	135B145   691	4401002131	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2641.02	Electrical	Electrical	Apartment			11/21/2016 12:00:00 AM			PC Approved	11/29/2016 12:00:00 AM	ADDRESS	34.06333	-118.47138	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar PV system, roof-mounted on aparment building.28kW (14+14) ungrounded system. (96) 310W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74679	13041-10000-35171	18080 W CHATSWORTH ST # C	91344	12	207B125   637	2731008***	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			12/18/2013 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.26439	-118.52639	PLAN CHECK FOR T24 ENERGY ONLY. NO CHANGE IN OCCUPANCY ACCORDING TO APPLICANT. RESTAURANT. 2200 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74680	13041-20001-15311	133 W AVENUE 45	90065	1	147A223   187	5467009001	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1851.00	Electrical	Electrical	Commercial			07/24/2014 12:00:00 AM			PC Approved	07/24/2014 12:00:00 AM	ADDRESS	34.09657	-118.20819	Plan check for additional of (6) 4' fluorescent light fixture for outdoor lighting.(((Title 24 only, reatil space, existing time control)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74681	13041-10002-00572	7122 W BEVERLY BLVD	90036	5	138B181   432	5513002032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Info Complete	03/11/2013 12:00:00 AM	ADDRESS	34.07599	-118.34481	MODIFICATIONS TO APPROVED SET OF PLANS UNDER PLAN CHECK NUMBER 13041-10001-00572. PLAN CHECK ONLY. Modification is requested by the inspector for change of fixtures.  Modification is under delta 3 only.  Permit is existing under 13041-10000-04022 .  This plan for T 24 only .  Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74682	16041-30001-16369	710 N EL CENTRO AVE	90038	13	141B189  1235		(T)(Q)RAS3-1	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Commercial			02/01/2018 12:00:00 AM			PC Approved	02/01/2018 12:00:00 AM	ADDRESS	34.08386	-118.3243	02-01-2017 Changes to an approved set of plan. Changes include relocate panels B, AC, and L to DMS Distribution Panel, relocate lighting and receptacle in kitchen, basement, restroom. Changes has been clouded and appl to delta 2 only. Plan Check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74683	14041-20001-15311	16762 W LONDELIUS ST	91343	12	195B137   737	2688029073	RS-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			06/09/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	ADDRESS	34.22927	-118.49805	Expedited plan check per applicant request.  (((PV1.  Install 8.925 kW roof-mounted, utility-interactive PV system.  (2) transformerless inverters with DC converters.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74684	15041-20004-43046	964 S BERENDO ST PHASE 2	90006	10	129B197    17	5078008022	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2133.20	Electrical	Electrical	Commercial			12/28/2017 12:00:00 AM			PC Approved	12/28/2017 12:00:00 AM	ADDRESS	34.05378	-118.29358	"12.28.2017 - Plan check for modifications to approved set. Adding 30kVA transformer and panel ""L2DA"". New circuits. 58 new circuits. Update floor plans, home-runs, and panel schedules. Changes clouded delta M and N.======[[[[7/11/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA "" L "" CHANGES. REVISION OF LOADS AND ADDITION OF CIRCUITS IN THE PANELSCHEDULES FOR RECEPTACLES, TVS, SFD'S, WIFI AND PROJECTIONS SCREENS, MINOR CHANGES TO LIGHTING]]]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74685	17041-20000-00546	7333 N FULTON AVE	91605	2	186B157   443	2328029032	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	08/07/2017 12:00:00 AM		Permit Finaled	08/10/2018 12:00:00 AM	ADDRESS	34.20396	-118.42265	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from manufacturing to industrial multi-tenant catering kitchens. Total lighting area = 9,669 sq. ft.Note: Building application has been created under 16016-20000-18257	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74686	14041-20002-31545	6344 N TOPANGA CANYON BLVD UNIT 1010	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM			PC Approved	10/01/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	CHANGES TO APPROVED SET OF PLANS. RELOCATION OF LOADS. CHANGES TO T24. ALL CHANGES CLOUDED DELTA 8 AND 9	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74687	13041-10000-03776	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/20/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	13041-10000-03776T24 for LA Dodger for the suites, lobbies, and gallery. 11435 sqrfPERMIT WILL BE OBTAINED AT THE PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74688	17041-10001-28776	976 E 55TH ST	90011	9	108B209   893	5103019001	R2-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			PC Approved	10/27/2017 12:00:00 AM	ADDRESS	33.99242	-118.25841	EXPEDITE FEES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74689	16041-10002-03732	4954 N WHITE OAK AVE	91316	5	168B129   767	2290010024	(T)RS-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			05/04/2016 12:00:00 AM			PC Approved	05/04/2016 12:00:00 AM	ADDRESS	34.16089	-118.518	05/04/16Changes to an approved set of plans. Change include the pv system point of interconnection from a line side tap to the load side.Note: PC fees are $0 due to senate bill 1222, and the Permit is paid under PCIS#16041-10000-03732((((This is PC only.  Line side tap for PV connection per NEC 705.12(A) and 230.82(6), added Fuses within the AC disconnect. Permit under 16041-10000-03732Zero fees $0 due per California Senate Bill 1222.<<PV1, SOLAR ROOF MOUNTED SYSTEM USING MICRO-INVERTERS. (46) MODULES AND (46) MICROINVERTERS AND (100AMP) LOAD CENTER WITH A MONITORING SYSTEM. TOTAL SIZE 11.5KW-AC.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74690	19041-20000-40258	6455 N YARMOUTH AVE	91335	3	180B129   728	2123003012	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.18851	-118.51981	PLAN CHECK FOR NEW ESS TO EXISTING SFD. ESS SIZE IS 27 KWH. SCOPE OF WORK CONSISTS OF (2) TESLA POWER WALLS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74691	17041-20000-42004	10620 N PINYON AVE	91042	7	207B201   221	2566001072	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.26154	-118.28481	INSTALLATION OF ENERGY STORAGE SYSTEM 14KW TO EXISTING PV SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74692	13041-10002-04784	5055 W WILSHIRE BLVD #600	90036	4	135B181   924	5507020049	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/24/2013 12:00:00 AM			PC Approved	07/24/2013 12:00:00 AM	ADDRESS	34.06235	-118.34036	[[[[[[[[SUPPLEMENTAL APP FOR APPROVED SET OF PLAN WITH APP # 13041 10000 04784. ADDITION OF 400 AMP PANEL AND 112.5 KVA TRANSFORMER. REROUTING THE UPS FROM DPS TO ITS OWN TRANSFORMER. 7/24/2013.]]]]]]]]]PC POWER AND ENERGY. TI OFFICE->OFFICE. replace 1200A SWBD, 300 kva xfmr, and office TI. 6TH FLOOR HIRISE. no raised floor for server room. UPS is 100 KVA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74693	19041-10000-53050	1833 S LA CIENEGA BLVD	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	10/02/2020 12:00:00 AM	ADDRESS	34.04342	-118.37677	FULL PC FOR POWER AND ENERGY.  SCOPE INCLUDES NEW PANELBOARDS, NEW CIRCUITS, NEW LIGHTS, AND RECEPTACL. TOTAL AFFECTED AREA IS 57,548 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74694	19041-20000-46759	15629 S AINSWORTH ST	90247	15	072B197   337	6120004013	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Issued	11/13/2019 12:00:00 AM	PIN	33.88902528	-118.2907982	PV1.  Install 5.12 kW DC roof mounted grid tied PV system.  (16) modules with 3.8 kW rated inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74695	10041-10000-22101	310 W WASHINGTON BLVD BLDG #6	90292	11	105A147   253	4225003***	C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			11/10/2010 12:00:00 AM	12/16/2010 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	PIN	33.98038877	-118.46355239	NEW 6 UNIT TOWN HOME.   (BUILDING #6)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74696	19041-30000-01968	1839 S PANDORA AVE	90025	5	132B157   911	4317002022	RD1.5-1-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Apartment			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	06/11/2021 12:00:00 AM	ADDRESS	34.05552	-118.42445	Plan check for a fire alarm system for a 5-story, 4-unit apartment. System consists of (1) FACP and (36) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74697	14041-20000-04344	21820 W BURBANK BLVD	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/18/2014 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.17228	-118.6032	T.I. to existing building on third floor, Suite 300.  Relocate lights.  Plan check for energy only.Note: Permit issued under 14041-90000-02561	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74698	13041-20000-19239	8854 N TYRONE AVE	91402	6	195B149   302	2639005006	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2013 12:00:00 AM			Corrections Issued	07/22/2013 12:00:00 AM	ADDRESS	34.23149	-118.44815	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.1 KW USING 17 MODULES. USING TRANSFORMERLESS INVERTER, NONSTANDARD PLAN. 2 STRINGS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74699	16041-10001-22231	905 E 6TH ST	90021	14	126A213   264	5147015040	M2-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	11/30/2016 12:00:00 AM	ADDRESS	34.03982	-118.24098	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 1 ON PLANS. CHANGES INCLUDE REVISE LIGHTING LAYOUT AND UPDATED T24. REVISED SOME CIRCUITS AND NOTES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74700	12041-10003-29913	12760 W MILLENNIUM BLDG A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			03/06/2015 12:00:00 AM			PC Approved	03/13/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	"((3/6/2015))  BUILDING ""A"" REVISIONS TITLE 24 ONLY.  CHANGE OF FIXTURES TO LED.  TITLE 24 2008 STANDARDS TO BE USED.REVISION TO APPROVED PLANS. DELTA 10 - ADD NEW CENTRAL WATER HEATING, CIRCULATING PUMP FOR BUILDING AND REMOVE GAS WATER HEATER FOR DWELLING UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74701	11041-10000-19273	508 E WASHINGTON BLVD	90011	9	121-5A209  37	5127019017	[T][Q]C2-1-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			09/12/2011 12:00:00 AM			PC Approved	09/12/2011 12:00:00 AM	PIN	34.0285358	-118.26003536	TENANT IMPROVEMENT IN RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74702	13041-10000-23719	22935 W MARIANO ST	91367	3	171B097    78	2042008052	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			08/30/2013 12:00:00 AM	08/30/2013 12:00:00 AM		Permit Finaled	12/16/2013 12:00:00 AM	ADDRESS	34.16843	-118.62683	PV1 9.8KWdc 240V XFMR (neg grounded) INV. ?STORY. STD. ROOFMOUNT.[( 1) INV: FRONIUS IG PLUS V 7.5-1UNI][( 40) MOD: Trina {TSM-245PC05.18}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74703	14041-10002-21463	3335 S FIGUEROA ST O	90007	9	120A203   503	5123009042	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM			PC Approved	11/24/2014 12:00:00 AM	ADDRESS	34.02224	-118.28008	(((11/24/2014 - Sup application for changes to approved set.  Title 24 plan check only.  Addition of one light and a recepticle.)))Plan check at counter. New power/lighting system upgrade. electrical service for sub-lease space. T24. Area = 3450 sq. ft. 8 story building High rise	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74704	17041-20000-40507	6255 W SUNSET BLVD #600	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.09815	-118.32564	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT TO THE (E) OFFICE SPACE (3,996 SF); HIGHRISE. SUITE 600BUILDING P # 17016-20000-28155	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74705	10041-10000-22716	110 S FAIRFAX AVE	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			11/12/2010 12:00:00 AM	02/09/2011 12:00:00 AM		Permit Finaled	05/20/2011 12:00:00 AM	ADDRESS	34.07371	-118.36119	New restaurant in the Farmers Market.  Power and energy	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74706	19041-20000-24039	21160 W CALIFA ST	91367	3	174B105    17	2149002019	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM	07/17/2019 12:00:00 AM		Permit Finaled	07/29/2020 12:00:00 AM	ADDRESS	34.17691	-118.5929	T24 PLAN CHECK FOR NEW CHANGE OF USE BAKERY BLDG. TOTAL SQUARE FOOTAGE = 14270 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74707	17041-10000-35343	111 E AVENUE 26	90031	1	139-5A221 170	5205021002	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.0766	-118.21516	PC FOR OUTDOOR T-24, REPLACE EXISTING FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 25,800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74708	14041-20000-24868	7006 S HOOVER ST	90044	8	102B201   655	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/15/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	01/05/2015 12:00:00 AM	ADDRESS	33.97585	-118.28691	INSTALL ROOF MOUNTED PV SYSTEM SIZED 2KW INTERCONNECTED WITH House Panel.ENPHASE M250 MICROINVERTER.zoning clearance under this application shall be applicable for all solar installations under this building	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74709	19041-10000-29818	12746 W JEFFERSON BLVD	90094	11	102B161  1167	4211033012	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/01/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Issued	10/03/2019 12:00:00 AM	ADDRESS	33.97756	-118.41709	Energy pc only for Reconfigure planterz for 12751 millenium & reconfigure Fire Dep't access.  area of scope is 8,575 sqft. Emergency lighting to remain.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74710	13041-20000-19109	16357 W RAYEN ST PV-1	91343	12	195B137   343	2688007022	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	08/23/2013 12:00:00 AM	ADDRESS	34.23215	-118.48943	PV-1. Plan check. One for 4.2kW transformerless inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74711	13041-10001-27919	735 S FIGUEROA ST space #202	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	(((4/3/2014: CHANGES MADE TO LIGHTING PLAN. T24 HAS BEEN CHARGED. PERMIT WAS PULLED ON THE ORIGINAL APPLICATION NUMBER)))TITLE-24 ONLY PLAN CHECK FOR A RETAIL SPACE. SCOPE OF WORK IS < 400A. TI TO THIS RETAIL SPACE IS LOCATED IN A HIGH-RISE BUILDING. TOTAL AREA IS 1286. ELECTRICAL PERMIT TO BE PULLED AT THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74712	14041-20000-04850	17151 W SIMONDS ST	91344	12	213B133   833	2697015015	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.27655	-118.50672	Roof mounted PV system with 6.5KW dc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74713	15041-10000-43925	3287 W WILSHIRE BLVD	90010	10	135B197  1219	5502026021	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			12/30/2015 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.06197	-118.29379	PC FOR EMERGENCY LIGHTING ONLY, TO A BEAUTY SALON, GENERAL LIGHTING IS ALL EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74714	16041-20000-22294	11400 W OLYMPIC BLVD 625 & 630	90064	11	123B153    93	4260017024	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.03666	-118.44346	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. HIGH RISE. SUITE 625 & 630. 3357 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74715	17041-10000-01865	649 S OLIVE ST	90014	14	129A209   151	5144003904	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/19/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Issued	04/11/2017 12:00:00 AM	ADDRESS	34.047	-118.25536	PC FOR NEW FA SYSTEM TO EXISTING BUILDING WHICH IS BEING COMPLETELY RENOVATED. BUILDING IS 12 STORY WITH ROOF DECK - HIGH RISE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74716	18041-10000-22423	377 S CENTRAL AVE	90013	14	127-5A215 154	5147002001	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM			Reviewed by Supervisor	06/28/2018 12:00:00 AM	ADDRESS	34.04421	-118.23987	PLANCHECK FOR POWER AND ENERGY. NEW TWO-STORY OFFICE BUILDING WITH A MEZZANINE.BUILDING PERMIT # 17010-10000-05060	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74717	13041-10001-35017	21800 W VICTORY BLVD	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			03/24/2015 12:00:00 AM			PC Approved	06/18/2015 12:00:00 AM	ADDRESS	34.18712	-118.60325	"CHANGES TO PERMITTED SET OF PLANS-4000A SECTION ON MSB REMOVED; NEW 3000A DISCONNECT FOR MDP;GEN TAP BOX SUPPLIED FROM MDP; FEEDERS DISCONNECT CHANGED FROM FUSES TO CBs; sevice laterals changed from cu to al((((((((((PLANCHECK FOR POWER AND ENERGY FOR New 1 story retail ""COSTCO""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74718	18041-10001-40531	812 N EL ORO LANE	90272	11	129B121   293	4419012024	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM			PC Approved	11/09/2018 12:00:00 AM	ADDRESS	34.05077	-118.54807	EXPEDITED FEES PV1, PC FOR ROOF MOUNTED 11.4KVA PV ON SFD SCOPE INCLUDES (1) CENTRAL INVERTER(SOLIVIA 11.4 TL) WITH 36 MODULES AND TWO 5KW ENERGY STORAGE EQUIPMENT. TOTAL SYSTEM SIZE 11.7KWDC/11.4KWAC AND 27KWH ENERGY STORAGE SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74719	18041-10000-30144	6727 W 86TH PL	90045	11	096B161   681	4122014014	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2780.01	Electrical	Electrical	Apartment			08/09/2018 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	03/17/2020 12:00:00 AM	ADDRESS	33.95939	-118.40761	PC FOR T24 ENERGY ONLY FOR APARTMNET COMMON STAIRWELL AND OUTDOOR LIGHTS. SCOPE INCLUDES NEW LIGHTS ONLY. TOTAL AFFECTED AREA 1641 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74720	14041-10002-19481	3353 W SAN FERNANDO ROAD	90065	13	153B209    75	5458006903	[Q]PF-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.01	Electrical	Electrical	Commercial			09/14/2016 12:00:00 AM	09/14/2016 12:00:00 AM		Permit Finaled	05/10/2017 12:00:00 AM	ADDRESS	34.11883	-118.2495	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 3 ON PLANS. REVISED GROUND FLOOR PLAN. RECHECKED FIRE APPROVED SET FOR NEW LOCATION OF DEVICES. REVIEWED NEW VOLTAGE DROPS AND BATTERY SIZING CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74721	12041-10000-15252	200 S SAN PEDRO ST #402	90012	14	129A213    85	5161022023	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM			PC Approved	07/09/2012 12:00:00 AM	ADDRESS	34.04904	-118.24164	T.I. to an existing low-rise office building.  Load is less than 400A, per applicant.  PLAN CHECK ONLY for Energy, with Emergency.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74722	19041-10000-15819	11100 W SANTA MONICA BLVD 4TH FLR	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM	05/02/2019 12:00:00 AM		Permit Finaled	08/08/2019 12:00:00 AM	ADDRESS	34.04726	-118.44465	Energy plan check for INTERIOR REMODEL OF CORRIDOR, LOBBY, AND RESTROOMS ON THE 4TH  FLOOR OF A HIGH RISE OFFICE BUILDING. Scope includes new lighting and equipment with a total area of 777-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74723	16041-10000-31498	2049 S CENTURY PARK EAST	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/06/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Issued	09/06/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR AN EXISTING FIRE ALARM SYSTEM FOR AN EXISTING HIGH RISE COMMERCIAL BUILDING. SCOPE INCLUDES REPLACING 25 FA PANELS FOR FLOORS C, GARAGE P3, GARAGE D, P3, D, 1ST, 2ND, 4TH, 7TH, 10TH, 13TH, 17TH, 19TH, 22ND, 25TH, 28TH, 31ST, 34TH, 37TH, 40TH, AND 43RD FLOORS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74724	13041-10000-03624	19210 W BALLINGER ST	91324	12	201B117   652	2762011011	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.24369	-118.55216	PV1 for single story house. Total system size: 11.52 kW. [Inverter: Fronius IG Plus Model#: Fronuis IG Plus 10.0] [Solar Module: Trina Mount 2 Model#: TSM-245-PC/PA05.18]. 44 Modules used with 1 central inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74725	18041-20000-08183	1636 S SAWTELLE BLVD	90025	11	129B149   480	4261008006	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.04627	-118.44804	Plan check for power only. Project site is an existing commercial building. Project scope is the replacement of electrical distribution equipment due to a fire. Service size has remained the same. No new load has been added. Tenant panels have been replaced as noted.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74726	18041-10000-34301	767 S ALAMEDA ST 265	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	12/05/2018 12:00:00 AM	ADDRESS	34.03474	-118.24063	PLANCHECK FOR T24 ENERGY.  TENANT IMPROVEMENT FOR OFFICE SPACE. SUITE 265. 1921 SQFT. BUILDING PERMIT # 18016-10000-26091	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74727	18041-10000-25000	200 S LOS ANGELES ST Suite A	90012	14	130-5A213 175	5161024039	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			07/05/2018 12:00:00 AM	09/13/2018 12:00:00 AM		Issued	09/13/2018 12:00:00 AM	ADDRESS	34.05007	-118.2433	PLANCHECK FOR POWER AND ENERGY PER APPLICANT. TENANT IMPROVEMENT 7-ELEVEN CONVENIENCE STORE;BUILDING PERMIT # 18016-10000-12234	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74728	17041-10000-34976	1358 W PACIFIC COAST HWY	90710	15	033B193    81	7411007066	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.78922	-118.30076	REPLACE HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74729	12041-10000-14557	8016 N HOLLYWOOD WAY	91352	2	189B181   178	2403024003	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Issued	07/20/2012 12:00:00 AM	ADDRESS	34.2166	-118.34461	Plan check for new roof mounted 11.5KW photovoltaic system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74730	14041-10000-20772	11630 W TUXFORD ST	91352	6	192B169   355	2632023049	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			08/01/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.22408	-118.38532	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74731	15041-10000-15144	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			Verifications in Progress	07/02/2015 12:00:00 AM	ADDRESS	34.06488	-118.47066	PER APPLICANT REQUEST ,NO EXTENSION OF TIME , WANT TO APPLY NEW TITLE 24, HRLY CHARGED.   M.Z 5-17-15  COMPLETE RENOVATION OF CLASSROOM BUILDING CONSISTING OF BASEMENT AND TWO STORIES ABOVE. INCLUDES NEW LIGHTING, RECEPTACLES, HVAC, PANELS, AND A NEW SERVICE. EXISTING AND NEW WORK IS DIVIDED BY A DASHED LINE ON SINGLE LINE DIAGRAM. APPLICANT BROUGHT PRE-CUT CHECK, FEES TO BE RECALCULATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74732	14041-20000-31723	15903 W STRATHERN ST	91406	6	189B141    56	2206005022	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			11/14/2014 12:00:00 AM			Reviewed by Supervisor	12/18/2014 12:00:00 AM	ADDRESS	34.21585	-118.47965	PV2. COMMERCIAL ROOF MOUNTED SOLAR SYSTEM.  NEGATIVELY GROUNDED SYSTEM. SYSTEM SIZE: 569.06 KW DC.(784) LONG SLSM 230P(1254) CANADIAN SOLAR CS6X(8) SOLECTRIA PVI-20TL(11) SOLECTRIA PVI-28TL	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74733	13041-20000-06684	3131 S FIGUEROA ST	90007	9	120A203    61	5123010012	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			03/14/2013 12:00:00 AM			PC Approved	03/15/2013 12:00:00 AM	ADDRESS	34.02389	-118.27894	Plan check for energy and emergency lighting. Addition of classroom less than 30000 sqft, occupancy less than 100, affected load less than 400A. Interactive Media Lab. USC School of Cinematic Arts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74734	18041-10000-22380	3921 W SUNSET BLVD FIRST FLR	90029	13	145-5A203 330	5429013002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	01/16/2020 12:00:00 AM	ADDRESS	34.09235	-118.27998	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. RESTAURANT. GROUND FLOOR. TOTAL AFFECTED AREA 4341 SQ. FT. BUILDING PERMIT # 18016-10000-16107	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74735	15041-10000-13880	11 E UNIVERSAL HOLLYWOOD DR	91608	4	162B177   352	2424044020	C2-1, PB-1, RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West		1437.00	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Issued	06/12/2015 12:00:00 AM				ADDING NEW 750KW GENERATOR FOR STUDIOS LOCATED ON THE TERRACE. PC FOR POWER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74736	13041-10000-27896	16731 W DEVONSHIRE ST	91344	12	204B137   263	2684004010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	11/13/2013 12:00:00 AM	ADDRESS	34.25765	-118.49696	PV1. ROOFMOUNTED SOLAR ARRAY. SYSTEM SIZE: 7.5 kW. STANDARD PLAN.  1 STORY HOUSE.(30) TRINA SOLAR # TSM-250PA05.18(1) FRONIUS # IG PLUS V 7.5	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74737	14041-10000-07035	1300 S SAN PEDRO ST # 102	90021	14	123A211    69	5132019001	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/17/2014 12:00:00 AM	03/17/2014 12:00:00 AM		Permit Finaled	03/28/2014 12:00:00 AM	PIN	34.03251075	-118.25377188	T24 ONLY REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW  FLORESCENT FIXTURES, TOTAL AREA 980 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74738	16041-10000-10135	9107 N VAN NUYS BLVD	91402	6	198B149   542	2651009055	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM	06/23/2016 12:00:00 AM		Permit Finaled	09/06/2016 12:00:00 AM	ADDRESS	34.23588	-118.45045	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING MCDONALDS RESTAURANT. SCOPE INCLUDES NEW LIGHTS FOR INDOOR AND OUTDOOR. TOTAL AFFECTED AREA IS 3675 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74739	12041-20000-23827	9205 N ALABAMA AVE #B	91311	12	198B105   108	2746011***	[Q]MR2-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.02	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.23803	-118.59986	Industrial. Title 24 plan check for energy only at counter. No emergency lights per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74740	15041-10000-36989	645 N ADELAIDE DR	90402	11	123A133    88	4410001051	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	01/28/2016 12:00:00 AM	ADDRESS	34.03297	-118.50905	PV1, ROOF MOUNTED SOLAR SYSTEM WITH MICRO INVERTERS. (38) MODULES AND (38) MICRO INVERTERS. TOTAL SIZE 9.5 KW.(38) PRO BFR-G3-250W(38) ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74741	16041-10000-06453	9894 W BEVERLY GROVE DR	90210	5	144B157    33	4356023015	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	11/14/2017 12:00:00 AM	ADDRESS	34.09521	-118.42384	PC FOR POWER. REMODEL EXISTING 3-STORY RESIDENCE W/ ATTACHED GARAGE. UPGRADE SERVICE TO 600A. ADDITION OF 5 NEW PANELS & ELEVATOR AND 3 AC UNITS.B # 15016-10000-18715	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74742	15041-10000-06351	7347 N CLAIRE AVE	91335	3	186B121   737	2104028005	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.02	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	34.20436	-118.55037	PV1, INSTALL  5.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER 327 W ;(1) INVERTER: ABB PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74743	14041-20000-11218	15246 W OLIVE LN	91342	7	228B145   832	2501016***	(Q)RD6-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2014 12:00:00 AM			Plans on Hold	05/14/2014 12:00:00 AM	PIN	34.31772164	-118.46527294	PV1. 2.25kw roof-mounted system with power optimizers, (9) canadian solar modules and (1) Solaredge SE3000A-US-ZB-U inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74744	15041-10000-13198	1390 E 7TH ST	90021	14	124-5A215   2	5146009005	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	08/12/2015 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.03498	-118.23893	PLAN CHECK FOR MEDIUM VOLTAGE (4800 V) DISTRIBUTION SYSTEM. THIS IS SUBSTATION BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74745	14041-20001-06257	12180 W MILLENNIUM WEST	90094	11	102B161  1145	4211010041	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM			PC Approved	12/01/2014 12:00:00 AM	ADDRESS	33.97975	-118.40731	Changes from previously approved plans.  Changes include the removal of indoor lighting and modified to the outdoor lighting.  Plan check for energy only.Note: Permit is under the original application.*****Previous Description*****FULL PLAN CHECK FOR OUTDOOR LIGHTING FOR PLAYA VISTA. THE AREA IS IN A METHANE ZONE AND REQUIRES FULL PLAN CHECK FOR HAZARDOUS LOCATION. T24 HAS BEEN PAID FOR ON APPLICATION#: 14041-20000-06148	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74746	13041-10002-36109	8532 N THUNDERBIRD DR	91343	6	192B145   727	2654020***	(Q)RD3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2014 12:00:00 AM			PC Approved	07/14/2014 12:00:00 AM	ADDRESS	34.22559	-118.46904	Plan check only. NO BOLLARDS REQUIRED FOR PHYSICAL PROTECTION. Per Senate Bill No.1222, Fee cap reached on original application, thus fee is $0.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74747	17041-10001-04616	20065 W RINALDI ST BLDG A4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.27548	-118.57184	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding site lighting, replacing exterior lights, revising title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74748	18041-20000-45410	4510 N RADFORD AVE	91607	2	165B169    21	2364006022	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM	11/29/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.15248	-118.39193	Plan check for a PV1 roof-mounted PV system. System size is 16.07 kWdc/15.05 kWac-CEC and consists of (2) inverters, (51) modules, (2) load centers, and (2) back-up batteries.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74749	15041-20000-36251	12707 W JUDD ST	91331	7	213B161   612	2532004021	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	02/08/2016 12:00:00 AM	ADDRESS	34.27957	-118.40969	Plan check for PV roof mounted system. System size: 3.0kW with 13 modules and 1 inverter(3.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74750	16041-10000-20429	242 E LANZIT AVE	90061	15	084B205    13	6083003009	RD2-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.01	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	33.93028	-118.27066	PV1, roofftop solar on SFD, 3.8 kW AC  (20) CS6P-265W   (1) Primo 3.8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74751	17041-10000-05968	3880 E SAN RAFAEL AVE	90065	1	148-5A221  25	5465001004	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM	02/24/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.10212	-118.21724	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES RELACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 57200 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74752	17041-10000-16947	700 S FLOWER ST #800	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/19/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	08/29/2017 12:00:00 AM	ADDRESS	34.04835	-118.25882	PC for energy only, Indoor Title 24. Tenant improvement on suite 800. New lighting and Power. Area: 3,423 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74753	19041-20000-23387	8802 N VAN NUYS BLVD	91402	6	195B149   432	2639001017	[Q]CR-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	Apartment			06/18/2019 12:00:00 AM	11/06/2020 12:00:00 AM		Permit Finaled	05/23/2022 12:00:00 AM	ADDRESS	34.2301	-118.45005	1200A 240/120V 3ph-4w service, distribution, power, and lighting for new building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74754	12041-10000-07366	5990 N SEPULVEDA BLVD 400	91411	2	177B145   487	2243019023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			03/30/2012 12:00:00 AM	03/30/2012 12:00:00 AM		Permit Finaled	01/11/2013 12:00:00 AM	ADDRESS	34.17911	-118.46588	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT FOR SUITE #400. PERMIT FOR NEW BRANCH CIRCUITS. LESS THAN 400A LOAD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74755	12041-10000-16398	1610 N ARGYLE AVE	90028	13	148-5A189 256	5546028012	C4-2D	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM	03/14/2013 12:00:00 AM		Permit Finaled	11/01/2013 12:00:00 AM	ADDRESS	34.10017	-118.32503	PLAN CHECK POWER AND ENERGY FOR CONVERTING EXISTING TWO STORY OFFICE BUILDING TO A 20-UNIT HOTEL BUILDING. NEW 800A SERVICE AND ELECTRICAL SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74756	14041-10000-03738	862 S MAIN ST	90014	14	127-5A209 294	5145015002	[Q]C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/10/2014 12:00:00 AM	04/15/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.04148	-118.25466	change of use to coffee shopplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74757	10041-10000-11487	645 W 9TH ST # 106	90017	9	129A207   330	5144027***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	06/23/2010 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	PIN	34.04579989	-118.26058615	T-24 only for space 106 in a low rise building on the ground floor.   The architect telephoned and indicated that the building is low rise, and that based on the building code for the type of occupancy, that there are no emergency egress lighting requirements for the space.  TI FOR (E) RESTAURANT (798 SF) DUE TO CHANGE OF TENANT. NO CHANGE OF USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74758	18041-10001-13572	1508 N LACHMAN LANE	90272	11	135B121    50	4420035004	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM			PC Approved	10/24/2018 12:00:00 AM	ADDRESS	34.06302	-118.54979	SUPPLEMENTASL FOR CHANGES TO APPROVED SET OF PLANS - CHANGES INCLUDE RELOCATION OF POWER WALLS TO GARAGE AREA (INSPECTOR TO VERIFY PHYSICAL PROTECTION FOR EQUIPMENT IN GARAGE) - CHANGES NOTED UNDER DELTA 2	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74759	14041-20000-10657	18518-18526 W PARTHENIA ST	91324	12	195B125   900	2785004031	[Q]CM-1VL	North Valley	Northridge	Northridge South		1154.04	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Issued	04/23/2014 12:00:00 AM	ADDRESS	34.22805	-118.53686	PC FOR NEW SERVICE UPGRADE. 800A SERVICE PROVIDING POWER FOR 2 TENANTS. 400A EACH. PLAN CHECK FOR POWER ONLY. MAIN BREAKER TO BE TYPE LC SERIES RATED WITH DISTRIBUTION BREAKERS TYPE FA. SERIES RATE TO 100KAIC MAXIMUM. PER MANUFACTURE SPEC SHEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74760	14041-10000-17725	12655 W BEATRICE ST	90066	11	105B157   658	4211006017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			06/30/2014 12:00:00 AM			PC Approved	06/30/2014 12:00:00 AM	ADDRESS	33.98007	-118.41764	PC FOR ENERGY ONLY. T.I. OF OFFICE SPACE: TOTAL AREA 6850 SQ  FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74761	16041-20000-43704	9111 N SUNLAND BLVD	91352	6	195B173   632	2408004010	QM1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM	02/06/2017 12:00:00 AM		Permit Finaled	08/16/2018 12:00:00 AM	ADDRESS	34.23513	-118.36751	permit fee $0.00 by state senate bill no. 1222PV2. Install 52.65 kW roof mounted grid tied PV system on (E) commercial warehouse building.  (162) modules with (3) 14.4 kW rated central inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74762	15041-10001-01531	3553 S GREENFIELD AVE	90034	5	117B161   186	4252016026	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2718.01	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM			PC Approved	02/24/2015 12:00:00 AM	ADDRESS	34.01973	-118.41733	Expedited per applicant requestinstall roof mounted solar array, interconnect with main panel. system size: 11.475kW. 2 inverters. inverter1:4.2kW. inverter2: 3.6kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74763	18041-10000-29733	4666 W HOLLYWOOD BLVD	90027	13	147B197   410	5542014002	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.10048	-118.29116	PC FOR  (E) RESTAURANT INTERIOR T.I.  FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA  968SQ.FTSCOPE INCLUDES NEW PANEL, EQUIPMENT, CIRCUITS AND LIGHTS. B#18016-10000-18992	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74764	19041-20000-50784	1047 N BUNDY DR	90049	11	138B141  1105	4494005034	RS-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM			PC Approved	01/07/2020 12:00:00 AM	ADDRESS	34.07884	-118.48296	Plan check for power only, 600A service and associated load.Plan check only, Electrical permit paid for under Building Combination number16010-30005-03701/16010-10000-03701	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74765	13041-10000-13171	6330 W SAN VICENTE BLVD	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.06116	-118.36804	PLAN CHECK FOR MEDICAL FACILTIY. WORK IN PATIENT CARE AREAS. POWER AND ENERGY. CHANGE OF USE FROM OFFICE TO ORTHEPEDIC CENTER. COMMUNICATION EQUIPMENT NOT IN SCOPE OF PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74766	15041-10000-39890	19801 W NORDHOFF PL # 107	91311	12	198B113   149	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/25/2015 12:00:00 AM	11/25/2015 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.23568	-118.56464	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 6992 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74767	15041-10000-22844	4300 N ARCOLA AVE	91602	4	165B177   697	2424023008	RE11-1-H-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Expired	09/19/2017 12:00:00 AM	ADDRESS	34.14805	-118.35489	PV1, INSTALL 25.01 KW DC ROOF-MOUNTED SOLAR ARRAY ON RESIDENTIAL BUILDING. ZERO FEES DUE TO 2012 SENATE BILL NO. 1222.(82) MODULES:LG 305NIC-B3(82) INVERTER: ENPHASE M250-60-2LL-52X	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74768	13041-10000-26653	10339 N OSO AVE	91311	12	204B113    76	2707015020	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2013 12:00:00 AM	09/25/2013 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.25904	-118.57547	INSTALLATION OF AN AUTOMATIC AND MANUAL FIRE SPRINKLER MONITORING SYSTEM. SYSTEM(FULLY-SPRINKLER)  WILL HAVE NOTIFICATION THROUGHOUT THE COMMON AREAS. 18 DEVICES, 1 PANEL. OCCUPANCY ARE 3.1 PER BUILDING PERMIT ; NOTES INDICATED ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74769	17041-10000-05284	3268 W SLAUSON AVE	90043	8	108B185   923	4005005027	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Issued	02/21/2017 12:00:00 AM	ADDRESS	33.98884	-118.32949	NEW PC FOR A LOST APPROVED SET. PREVIOUS ELECTRICAL APP # 15041-10000-41241T-24, TI TO THE FACADE OF AN (E) RESTAURANT, POPEYES. SCOPE OF WORK INCLUDES NEW OUTDOOR LIGHTING ONLY. TOTAL SQ. FT. 2400.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74770	13041-10000-36131	6250 W HOLLYWOOD BLVD ST 600	90028	13	148-5A189 347	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.10133	-118.32547	TI IN A BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74771	17041-10000-08277	1000 W VIN SCULLY AVE	90026	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Commercial			03/16/2017 12:00:00 AM	03/24/2017 12:00:00 AM		Permit Finaled	03/31/2017 12:00:00 AM	PIN	34.07114879	-118.24664847	FULL PC FOR POWER AND ENERGY. TI REMODEL TO (E) DUGOUT CLUB @ DODGER STADIUM. A-OCCUPANT LOAD > 100.  SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 180 SQ. FT. B#17016-10000-06143	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74772	17041-20000-07105	10551 N ILEX AVE	91331	7	207B157   971	2620026006	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2017 12:00:00 AM	03/06/2017 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.26174	-118.41931	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (18) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74773	19041-10000-17582	6035 N SEPULVEDA BLVD	91411	6	177B145   441	2242001016	M2-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			05/10/2019 12:00:00 AM	05/10/2019 12:00:00 AM		Issued	05/10/2019 12:00:00 AM	ADDRESS	34.18036	-118.46656	Remove HID fixtures and replace with new LED fixtures (Indoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74774	13041-10000-16456	3000 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	12/17/2013 12:00:00 AM	ADDRESS	34.01674	-118.21552	Tenant improvement of office space and warehouse space in a cold storage facility.  More than 400 A of newly connected load.  Power and energy plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74775	12041-10000-03784	7307 N FIGUEROA ST BLDG B	90041	14	160-5A229   8	5690025006	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1815.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM	11/08/2012 12:00:00 AM		Permit Finaled	02/12/2015 12:00:00 AM	ADDRESS	34.13662	-118.18837	New 1 story commercial Building B core and shell on an existing lot.  Power and energy. Building B supplying exterior parking lot. (Building A is under a separate application 12041-10000-03794)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74776	16041-10000-40314	231 W VERNON AVE	90037	9	112-5A203  33	5111010036	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			11/15/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	02/07/2017 12:00:00 AM	ADDRESS	34.00394	-118.27727	Title 24 plan check.  Remove HID fixtures and replace with new LED fixtures. Total affected area is 31425 Sq. Ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74777	15041-10000-09212	6908 N VESPER AVE	91405	6	183B149   545	2219026067	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	Apartment			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/27/2016 12:00:00 AM	ADDRESS	34.19603	-118.45077	New fire alarm system for a new 49-unit apartment building. scope includes (1) fire alarm panel, (1) annunciator panel, (3) power supplies, and (149) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74778	17041-10000-10724	1501 E CENTURY BLVD	90002	15	091-5A213 210	6048010949	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	04/04/2017 12:00:00 AM		Permit Finaled	04/27/2017 12:00:00 AM	ADDRESS	33.94578	-118.24813	PC for energy only, Outdoor Title 24. Removing HID fixutres and Replacing them with new LED ones. Area: 31,250. Total of 30 units	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74779	16041-20000-00683	11022 S AVIATION BLVD	90045	11	087B173    10	4129036908	LAX, M2-1	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.93576	-118.3779	Remodel and addition to (E) restaurant space.  Total 9800 sq ft interior, 3200 sq ft. exterior hardscape lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74780	15041-20001-11196	13739 W ERWIN ST	91401	2	177B153   388	2239007027	RE9-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2015 12:00:00 AM			PC Approved	04/29/2015 12:00:00 AM	ADDRESS	34.18315	-118.43271	Supplemental application for expedite fees only.Installation of new roof mounted solar PV array.  Total system size = 12 kWac.  Two inverter system with four strings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74781	16041-10000-05537	8635 W 3RD ST STE 876	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.07373	-118.38073	TI on (E) medical office suite#876, install new lightings and control receptacles using existing branch circuits. Total area 980 sq.ft. PC for T-24 only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74782	14041-10000-34657	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM	10/06/2015 12:00:00 AM		Issued	10/06/2015 12:00:00 AM	ADDRESS	34.04797	-118.25815	New fire alarm system for a existing retail section at the bloc core and shell for renovations on Level B thru roof.  Some existing devices with 453 new FA devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74783	18041-10000-09538	12020 W BURBANK BLVD	91607	2	174B165   752	2348002042	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	08/10/2018 12:00:00 AM		Issued	08/10/2018 12:00:00 AM	ADDRESS	34.17198	-118.39447	permit fees ar $0 due to senate bill 1222 and Assembly bill 1414Plan check for a commercial PV roof mounted system.SYSTEM SIZE 468.5KW DC/ 444KW AC(6) 60kw inverters(4)36KW INVERTERS, (4) ckts and (1358) modules interconnecting through (2) subpanel and and(2) new 300kva AND 225KVA  transformers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74784	18041-10000-23571	4201 W WILSHIRE BLVD 6TH FL	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.06189	-118.31911	PC FOR ENERGY ONLY TO A PUBLIC RESTROOMS TI ON 6TH FLR OF OFFICE BUILDING.SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1015.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74785	17041-20000-38956	23534 W HATTERAS ST	91367	3	174B093   126	2041009010	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.17537	-118.63964	Install 13.5 kWh energy storage system for SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74786	14041-20000-15000	19325 W ROMAR ST	91324	12	204B117   307	2726017001	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	07/23/2014 12:00:00 AM	ADDRESS	34.25551	-118.5546	New roof mounted PV system with transformerless inverters.  Total system size 11KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74787	13041-10000-13647	1032 S CRENSHAW BLVD A-I	90019	10	129B189    73	5081004024	C2-1-O	Central	Wilshire	Olympic Park		2127.01	Electrical	Electrical	Commercial			05/24/2013 12:00:00 AM			PC Approved	05/28/2013 12:00:00 AM	ADDRESS	34.0536	-118.32335	pc for energy only at inspector's request. TI TO EXISTING SPACE. SUBDIVIDE NEEDS TO MEET CONTROLS. less than 400A. Princess Nail Spa Suite A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74788	16041-10000-24005	8045 N LANKERSHIM BLVD	91605	6	189B169   119	2310007030	M1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Commercial			07/08/2016 12:00:00 AM			PC Approved	07/08/2016 12:00:00 AM	ADDRESS	34.21687	-118.38798	Title 24 plan check only.  Total area = 2,504 sq. ft. (indoor) + 700 sq. ft. (outdoor)T.I. to existing restaraunt.  New lighting and receptacles.Building permit #16016-10000-02512	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74789	13041-10000-09760	14006 W RIVERSIDE DR SPACE #226	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/16/2013 12:00:00 AM			PC Approved	04/16/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	Tenant improvement of an existing retail store (space #226): partitions, doors, fixtures, ceilings, etc.PLAN CHK IS FOR TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74790	17041-20002-15635	700 S NEW HAMPSHIRE AVE	90005	10	132B197   232	5094011018	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	08/25/2017 12:00:00 AM	ADDRESS	34.05951	-118.29274	changes to an approved set of plans.  changes made to single line diagram to reflect field conditions.this is plan check only.  (((((Plan check for solar pv system, roof mounted on commercial building.9.6kW ungrounded system. (40) EnPhase M250 microinverters.(40) 340W pv modules.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74791	19041-10000-41527	9413 N REVERIE ROAD	91042	7	198B197   223	2562011004	A1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Issued	10/11/2019 12:00:00 AM	ADDRESS	34.24099	-118.29411	NEW ROOF MOUNTED 9.9KW PV SYSTEM WITH 27 PV PANELS AND OPTIMIZER AND ONE CENTERAL INVERTER ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74792	16041-20001-45670	8007 N MAESTRO AVE	91304	12	189B093   267	2020018031	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			12/29/2016 12:00:00 AM			PC Approved	01/19/2017 12:00:00 AM	ADDRESS	34.21532	-118.63983	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 200A MSP.Derating the main breaker to 175A. 11.52kW ungrounded system. (36) 345W AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74793	16041-10000-15801	4206 W DON ORTEGA PL	90008	8	114B181   465	5031014003	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2364.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	05/27/2016 12:00:00 AM	ADDRESS	34.00757	-118.34885	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (34)MODULES-SOLARCITY STANDARD(1)INVERTER-FRONIUS #PRIMO 7.6	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74794	14041-20000-33241	10424 N WOODMAN AVE	91345	7	204B149    36	2648011015	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	04/15/2015 12:00:00 AM	ADDRESS	34.25984	-118.45405	PV1 SFD TOTAL SYSTEM SIZE 4KW AC USING TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. USING 13 MODULES IN TOTAL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74795	15041-10000-04395	10050 N REMMET AVE	91311	12	204B105   824	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	07/13/2015 12:00:00 AM	ADDRESS	34.25323	-118.60034	Title 24 plan check only.  Total area = 12,024 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74796	15041-10000-39258	8000 W SUNSET BLVD B145	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/19/2015 12:00:00 AM	11/30/2015 12:00:00 AM		Permit Finaled	12/22/2015 12:00:00 AM	ADDRESS	34.09783	-118.36466	new ckts and luminaires in modified retail space by the owner  in preparation for leasing plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74797	17041-20001-39712	11335 N HERRICK AVE	91331	7	210B157    40	2534005025	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM			PC Approved	11/07/2017 12:00:00 AM	ADDRESS	34.2761	-118.42036	VOID.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74798	11041-10000-20431	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			09/26/2011 12:00:00 AM			Corrections Issued	10/11/2011 12:00:00 AM	ADDRESS	34.27548	-118.56626	T.I. to an existing McDonald's inside a Wal-Mart.  PLAN CHECK ONLY for Energy with emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74799	13041-10000-24541	320 W 15TH ST	90015	14	124-5A207  85	5134015025	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Public Safety Only			09/09/2013 12:00:00 AM	09/09/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	34.03668	-118.26664	Replacing fire warning panel with a compatible addessable type and adding  9ea fire warning devices	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74800	15041-20001-32707	222 N CARMELINA AVE	90049	11	132B141    47	4405004007	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2015 12:00:00 AM			PC Approved	10/16/2015 12:00:00 AM	ADDRESS	34.06095	-118.48416	Expedited per applicant request.Plan check for a Pv1 roof-mounted PV system. System size is 12.5 kWac and consists of (50) micro-inverters, (50) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74801	14041-20001-30006	17100 W LABRADOR ST	91325	12	201B133   154	2692012020	A2-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2014 12:00:00 AM			PC Approved	01/23/2015 12:00:00 AM	ADDRESS	34.24973	-118.50513	EXPEDITE PER APPLICANT REQUEST[PV1Install roof-mounted solar array on SFD, interconnect with a 200A bus of a 400A split main panel.Derating main breaker.System size: 12.5kW (5+7.5). Grounded system.53 275W pv modules across 5 strings (3 strings of 11 on 7.5kW inv, 2 strings of 10 on 5kW inv).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74802	14041-10000-26921	725 S FIGUEROA ST 23RD FLOOR	90017	14	129A207   336	4226001902	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/30/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	34.04886	-118.26071	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY. <400 AMPS NEWLY CONNECTED LOAD. 13083 SQFT, EMERGENCY LIGHTING.  23RD FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74803	17041-10001-22483	1430 W E ST	90744	15	030B201   666	7412021035	[Q]M3-1VL-O-CUGU	Harbor	Wilmington - Harbor City			9800.15	Electrical	Electrical	Commercial			01/17/2018 12:00:00 AM	01/18/2018 12:00:00 AM		Permit Finaled	01/11/2019 12:00:00 AM	ADDRESS	33.77453	-118.28036	PC for changes to approved set. Changes include new pull section, updated service entrance conduit configuration with seal offs, updated equipment ratings, updated feeder run configuration and equipment locations. All changes are labeled under delta D and E.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74804	18041-20000-04698	21600 W OXNARD ST ste 380	91367	3	177B105    84	2146006043	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.179	-118.6002	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74805	14041-10000-35183	14801 W CALIFA ST	91411	4	177A149   146	2244009030	M1-1, P-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			12/19/2014 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	10/28/2015 12:00:00 AM	ADDRESS	34.17768	-118.45513	Power plan check for owner improvement; project is design build; work  includes new service upgrade to 1200-amp, and installation of new panels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74806	17041-10001-43290	221 N WESTMORELAND AVE	90004		138B197   515	5501008024							Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.07516	-118.28805	EXPEDITE PER APPLICANT REQUEST. ((((PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS  54.4KWdc / 66.6KWac.(160)MODULES-REC REC340TP72(80)OPTIMIZERS-P700(2)INVERTERS-SOLAREDGE SE33.3KUS 480Y/277V	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74807	13041-10000-26121	21710 W VANOWEN ST	91303	3	180B105    95	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/20/2013 12:00:00 AM	06/24/2014 12:00:00 AM		Issued	06/24/2014 12:00:00 AM	ADDRESS	34.19342	-118.60185	PLAN CHECK FOR TITLE 24 ONLY.  REPLACING INTERIOR FIXTUERES + ADDIING AND REPLACING EXTERIOR FIXTURES. 1 STORY BUILDING. 7404 INDOOR + 4371 OUTDOOR SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECRICAL PLAN CHECK COUNTER.  CHANGE OF USE FROM RESTAURANT TO OFFICE INCLUDING(FROM SIZZLER TO OFFICES)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74808	17041-20002-02157	23001 W MULHOLLAND DR	91364	3	165B097    72	2074038001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2017 12:00:00 AM			PC Approved	02/21/2017 12:00:00 AM	ADDRESS	34.15169	-118.62644	2.21.2017 - Plan check for modifications to approved set. Update module layout on roof. Change AC combiner rating from 200A to 60A. No other changes.======Plan check for a PV1 roof-mounted PV system. System size is 11.2 kWac and consists of (40) modules, (40) micro-inverters, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74809	11041-10000-21607	1599 E CAMPUS ROAD	90041	14	157-5A221 169	5474012025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00, 1834.00	Electrical	Electrical	Commercial			10/11/2011 12:00:00 AM	10/11/2011 12:00:00 AM		Permit Finaled	06/12/2012 12:00:00 AM	ADDRESS	34.12581	-118.21419	New fire alarm system with central station monitoring for an occupancy A building on the campus of occidental college	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74810	18041-10000-04072	5031 N ALONZO AVE	91316	5	171B129   362	2182007002	RA-1	South Valley	Encino - Tarzana	Encino		1395.02	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	10/22/2020 12:00:00 AM	ADDRESS	34.16167	-118.52046	PC for power and energy for maintanenance building. All fees for project are covered under 18041-10000-04057. B# 18010-10000-00400.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74811	19041-10000-31818	725 E 59TH ST	90001	9	105B205    20	6007002024	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			08/14/2019 12:00:00 AM	08/15/2019 12:00:00 AM		Permit Expired	02/01/2023 12:00:00 AM	ADDRESS	33.9873	-118.26208	Remove HID fixtures and replace with new LED fixtures (Indoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74812	18041-10000-13520	8025 S MAIN ST	90003	9	099B201   870	6031025027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2397.01	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	02/13/2019 12:00:00 AM	ADDRESS	33.96613	-118.27414	REPLACE OUTDOOR HID FIXTURES WITH NEW LED FIXTURES. TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74813	19041-20000-28533	5749 W SPRING OAK DR	90068	4	154-5A191 213	5580021008	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.1175	-118.31504	Plan check  for PV roof mounted system with Battery backup system, PV system size: 8.4KW DC System 7.68KW AC with 24 AC Modules and Tesla Battery PoweWall 2.0 13.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74814	13041-20000-17589	523 W 6TH ST SUITE 741	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	PIN	34.04872199	-118.25441618	T24 FOR EXISTING HIGHRISE OFFICE ON THE 7TH FLOOR SUITE 741. TOTAL SQRFT 1163	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74815	13041-20000-26351	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.24317	-118.50383	210kw roof mount Commercial PV system. PERMIT HAS ALREADY BEEN ACQUIRED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74816	17041-20001-14346	9301 N TAMPA AVE	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			Corrections Issued	02/20/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	02/20/2018 Changes to an approved set of plans. All changes have been clouded. Fixtures have been repositioned and type has changed.*****Previous Work Description*****Plan check for energy only. New outdoor lighting installed under solar carport, located on roof of parking garage (at the Northridge Fashion Center).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74817	14041-10000-02834	225 S GRAND AVE	90012	14	132A211    60	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	09/26/2014 12:00:00 AM	ADDRESS	34.05388	-118.25078	PLAN CHECK FOR FIRE ALARM IN A NEW HIGH-RISE BUILDING CONSISTING OF PULL STATIONS & SMOKE DETECTORS THROUGH OUT THE COMMON AREAS; FULLY-SPRINKLED SYSTEM FOR 20 FLOORS ( EXCLUDING 13TH FLOOR). 4 STORY PARKING UNDERNEATH THE BUILDING. [[[[[CHANGE OF CONTRACTOR( DESIGN BUILD) FROM PREVIOUSLY SUBMITTED PC #13041-10000-23253]]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74818	19041-20001-33741	2581 N WALLINGFORD DR PV1	90210	5	153B153    16	4382007046	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2019 12:00:00 AM	08/28/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.11951	-118.43391	$0 FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET. CHANGE ON COVER PAGE, CALCULATIONS, ROOF PAGE, AND SINGLE LINE. CHANGE IN PV MODULE AND INVERTER MODEL, FEEDER SIZES,  ADDITION OF SUB PANEL, AND CHANGE TO MAIN PANEL LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74819	19041-20000-11874	9900 N WILBUR AVE pv1	91324	12	201B121    98	2729007014	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	07/22/2019 12:00:00 AM	ADDRESS	34.25048	-118.54464	pv1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74820	13041-20000-01775	225 S 26TH ST	90049	11	129B137   520	4264001008	C1-1XLD	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	05/30/2013 12:00:00 AM	PIN	34.04786183	-118.49061927	Plan check for 800A service. Replacement of damaged 800A service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74821	17041-10000-21116	1149 S HILL ST SUITE  975	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			PC Info Complete	06/22/2017 12:00:00 AM	ADDRESS	34.03926	-118.26099	INTERIOR TENANT IMPROVMENT TO INCLUDE NEW INTERIOR NON-BEARING PARTITIONS, CEILING AND FINISH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74822	10041-20001-12012	10351 W WASHINGTON BLVD	90232	10	117B165   199	4208006017	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	10/03/2011 12:00:00 AM	ADDRESS	34.01918	-118.40198	Changes from previously approved plans.  Changes include relocate main panel and subpanels, and install LED luminaires.  Plan check for power and energy.*****Ti in two story office building. Plan check for power and energy. *****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74823	18041-10000-18540	21110 W OXNARD ST	91367	3	177B105    76	2149002023	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			06/04/2018 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	03/29/2022 12:00:00 AM	ADDRESS	34.17903	-118.59355	FULL PC FOR POWER AND ENERGY. NEW 7 STORY HOTEL WITH ONE LEVEL SUBTERRANEAN PARKING. SCOPE INCLUDES INSTALLING A NEW 1600A 480/277V 3 PHASE 4 WIRE SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74824	13041-10000-29540	810 S BROADWAY	90014	14	127-5A209 152	5144016065	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	34.04333	-118.25487	"FIRE ALARM TI TO COMMERCIAL 2 STORY + ROOF BUILDING. 53 TOTAL DEVICES WITH 1 CONTROL PANEL , 1 FIRE ALARM PANEL. OCCUPANT GROUP ""M"".  NON-SPRINKLERED SYSTEM.""COMPLY WITH DEPARTMENT ORDER effective date 06/29/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". All permits shall be for the same time period limitation."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74825	14041-10000-32913	2673 N NEWELL ST	90039	13	148-5A213 318	5442015010	R2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	12/10/2014 12:00:00 AM	ADDRESS	34.09986	-118.24652	Installation of new roof mounted solar PV array.  Total system size = 3.8 kWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74826	18041-10000-03003	8800 N OAK PARK AVE	91325	12	195B133   330	2690011013	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Finaled	04/23/2018 12:00:00 AM	ADDRESS	34.23036	-118.50536	PC for 11.52kW (AC) rooftop solar on SFD. Installing 36 AC modules (12.96kW(dc)) and one load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74827	14041-20000-32552	18217 W DONMETZ ST	91326	12	210B125   133	2715032029	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.27433	-118.5303	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 4.73kW. Ungrounded system.22 EnPhase M215-IG microinveters with 22 250W pv modules across two strings (9+13).Note: the solar PV installation shall comply with FPB Requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74828	13041-20000-21920	1400 N SPRING ST	90012	1	136-5A217  81	5409004007	MR2-1	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Issued	10/21/2013 12:00:00 AM	PIN	34.06649464	-118.2323089	upgrade servuce to 600 amps add elevator 20 hp change 3 panels for series rating brakers	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74829	15041-20000-07677	14630 W PLUMMER ST	91402	6	198B149    69	2650026900	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			03/16/2015 12:00:00 AM	03/16/2015 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.2424	-118.45147	PC FOR POWER CONNECTION OF A DIESEL FUEL TANK AND DISPENSER. AREA CONSIDERED CLASSIDFIED LOCATION. PROVIDE CONDUIT SEALS. CHECK FOR POWER CONNECTION ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74830	12041-10000-05568	144 N WOODBURN DR	90049	11	138B145   739	4429028042	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2012 12:00:00 AM			PC Info Complete	04/16/2012 12:00:00 AM	ADDRESS	34.0707	-118.47052	PLAN CHECK FOR NEW  2-STORY SINGLE FAMILY DWELLING OVER BASEMENT WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74831	10041-10000-05662	5832 S VERMONT AVE	90044	9	108B197  1460	6004001023	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00, 2371.00	Electrical	Electrical	Commercial			03/30/2010 12:00:00 AM	04/07/2010 12:00:00 AM		Permit Finaled	05/19/2010 12:00:00 AM	ADDRESS	33.98854	-118.29128	Plan check power and energy. Change of use from Retail (1650 sq.ft. portion) to Medical Office. Existing service and panel.  The PHP units installed on the roof are existing based on engineers statment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74832	18041-10000-10013	7660 N DENSMORE AVE	91406	6	186B141    19	2206011027	M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Issued	03/20/2018 12:00:00 AM	ADDRESS	34.21008	-118.47699	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74833	14041-10001-27169	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM			PC Info Complete	12/15/2017 12:00:00 AM	ADDRESS	34.04342	-118.25478	SUPPL. PLANCHECK ONLY FOR POWER AND ENERGY.  ADAPTIVE REUSE BUILDING based on 2014 NEC. Orginal submitted Plans were LOST.  Conversion from office space to residential/mixed use building. 8 Story building with 6 (Live/Work) units and commercial on the first and second floors.Permit must be issued prior to 1/29/2018.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74834	18041-20000-30381	19520 W NORDHOFF ST #4	91324	12	195B117    12	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	10/30/2018 12:00:00 AM		Permit Finaled	02/25/2019 12:00:00 AM	ADDRESS	34.23378	-118.55808	ti to an existing commercial space.  adding new lighting new controls to existing panels.  plan check for indoor lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74835	19041-10000-23242	221 S AVENUE 22	90031	1	138A221   131	5204006900	PF-1-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1997.00	Electrical	Electrical	Commercial			06/18/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.07292	-118.21761	Design Built. Power plan check for a 600-amp service 277/480v with (1) 500kva transformer supplying (4) level-3 EV chargers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74836	15041-10001-42671	9716 N GLADBECK AVE	91324	12	201B121   416	2763033024	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2016 12:00:00 AM			PC Approved	03/11/2016 12:00:00 AM	ADDRESS	34.2469	-118.53948	Chanes to an approved set of plans. (((PV1, INSTALL 7.50 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(30) MODULES: PHONOSOLAR PS 250P(30) MOICRO INVERTER: ENPHASE M215-60-2LL-S22)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74837	19041-10000-33328	20101 W RINALDI ST SUITE 120	91326	12	213B113   483	2701100006	(T)C4-2D, C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2019 12:00:00 AM			PC Info Complete	10/16/2019 12:00:00 AM	ADDRESS	34.27545	-118.57197	Full plan check. Scope includes new lighting and equipment with a total lighting area of  980-SQ FT  .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74838	12041-10000-02898	2219 E 1ST ST	90033	14	127-5A223  87	5183005050	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Commercial			02/09/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	10/18/2023 12:00:00 AM	ADDRESS	34.0446	-118.21143	Remodel of an existing Medical Clinic, new receptacles, loads, and lighting.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74839	15041-20000-32085	12050 W VENTURA BLVD C-202	91604	2	162B165   141	2369015019	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			10/01/2015 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	07/05/2016 12:00:00 AM	ADDRESS	34.14349	-118.39426	TI TO EXISTING RESTAURANT. FULL CHANGE OUT OF INTERIOR. NEW LIGHITNG. NEW EQUIPMENT. PC FOR POWER AND ENERGY. new connected load less than previous tenant	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74840	19041-20000-34478	3700 N BARHAM BLVD	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Apartment			08/30/2019 12:00:00 AM	10/23/2020 12:00:00 AM		Permit Finaled	09/09/2022 12:00:00 AM	ADDRESS	34.14064	-118.34139	PV2.  Install 151.2 kW AC / 170.955 kW DC roof mounted grid tied PV system.  (393) modules with (4) 9 kW and (8) 14.4 kW rated inverters.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74841	10041-10000-12501	215 W 5TH ST 1-88	90013		129A211    77	5149024005	[Q]C4-4D-CDO		Central City	Downtown Los Angeles			Electrical	Electrical	Commercial			06/30/2010 12:00:00 AM			PC Info Complete	09/16/2010 12:00:00 AM	ADDRESS	34.04788	-118.25017	"Remodel to an existing high rise building with 88 units adaptive reuse.  New services, switchboards, emergency generator, panels, and branch circuits.  Install general/emergency lighting.  File variance for separate fire alarm plans.  EPC is for power and energy.  ""COMPLY WITH DEPARTMENT ORDER effective date 08/04/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"".  Existing permit issued on application number 09041-10000-15831.  A new plan check was generated due to redesign."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74842	19041-10000-25371	14061 W ROSCOE BLVD BUILDING A	91402	6	192B153   770	2638037017	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	07/19/2022 12:00:00 AM		Issued	07/19/2022 12:00:00 AM	ADDRESS	34.22179	-118.43948	Full plan check for a new construction (Building A). Scope of work includes new lighting and equipment and new distrubtion panels feeding several subpanels. Note Building A shares a new service (4000 A) with a new performance center (Building B). Building B is under the plan check number: B# for building A: 19010-10000-00179B# for Building B: 19010-10001-00180	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74843	18041-10000-08912	17516 W RAYMER ST	91325	12	192B129    81	2787024009	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM	03/12/2018 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	34.22601	-118.51651	PV 1, roof mounted solar system using central inverters. (46) modules and (2) 7.6  and 6.0 Fronius inverters. Total system size is 12.65KWDC / 13.6 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74844	14041-10000-31775	2748 W 8TH ST Suite 202	90005	1	132A201    62	5077021028	C2-1	Central	Wilshire	MacArthur Park		2122.02	Electrical	Electrical	Commercial			11/17/2014 12:00:00 AM			PC Approved	11/18/2014 12:00:00 AM	ADDRESS	34.05747	-118.28552	Plan check for Title 24 only. Tenant improvement. Total lighting area = 3,829 sq. ft. Project space is commercial.  Existing permit under 14041-10000-31395	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74845	19041-10000-16841	770 W WILSHIRE BLVD	90017	14	129A209    51	5144006900	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/14/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.04914	-118.25811	PC for Energy only for 11 floors for Los Angeles community college district. Work scope Area(126,856)sf. all branch circuits are existing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74846	15041-20000-01210	10338 N LINDLEY AVE	91326	12	204B125   120	2731010016	R3-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Apartment			01/14/2015 12:00:00 AM	02/25/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.25844	-118.5272	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 20.0KW INTERCONNECTED WITH MSP.THIS IS 1  PV DESIGN OF TWO.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74847	14041-10000-07372	8511 W BEVERLY PL	90048	5	138B173   350	4337012040	C2-1VL-O	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Public Safety Only			03/19/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	07/30/2015 12:00:00 AM	ADDRESS	34.07669	-118.37705	NEW FIRE ALARM SYSTEM FOR A SCHOOL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74848	13041-10000-34969	11991 N NUGENT DR	91344	12	216B129   178	2601051018	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Expired	12/16/2014 12:00:00 AM	ADDRESS	34.28926	-118.5161	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH (E) 200A MAIN SERVICE PANEL IN 2-STORY BUILDING. SYSTEM IS TRANSFORMERLESS, & SIZED @ 9kW DC, WITH THE FOLLOWING ITEMS:(36) MODULES: ET-P660250(2) INVERTERS: POWER-ONE-PVI-3.6-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74849	13041-10001-01573	7402 N VARNA AVE	91605	2	186B157   348	2328029016	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			05/15/2013 12:00:00 AM			PC Approved	05/15/2013 12:00:00 AM	ADDRESS	34.20486	-118.42457	MODIFICATION/SUPPLEMENTAL TO APPROVED SET OF PLANS 13041-10000-01573. DELTA 3 CHANGES. CHANGE TO METERS.************************************************************************Single story building Remove existing 400A 240V Service and install new 600A 277/480V Service. Adding new 400A panel. Installation of industrial machines.  No work on lighting.  Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74850	17041-10003-44137	8352 N CANTALOUPE AVE	91402	6	192B153   625	2637030022	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			PC Approved	03/12/2018 12:00:00 AM	ADDRESS	34.22301	-118.43567	03-02-2018 Changes to an approved set of plan. Changes include revision to a sub-panel load distribution. Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74851	10041-10000-18407	611 W 7TH ST	90017	9	129A209   115	5144006023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/16/2010 12:00:00 AM	09/17/2010 12:00:00 AM		Permit Finaled	04/14/2011 12:00:00 AM	ADDRESS	34.04768	-118.25692	+REMODEL THE BAR AREA INSDE A RESTAURANTPLAN CHKIS FOR TITLE 24  REF.#10042-10000-07103	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74852	13041-10000-06233	14608 W VENTURA BLVD	91403	4	166-5A151 120	2276001016	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			03/11/2013 12:00:00 AM			PC Approved	03/29/2013 12:00:00 AM	ADDRESS	34.15117	-118.45123	Energy compliance plan check for an Urban Outfitter's TI in a retail space (formerly a Tilly's).  Interior lighting only, space is 10000 sq ft and uses tailored method.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74853	14041-10000-06435	11901 W SANTA MONICA BLVD #108-#110	90025	11	126B145   436	4263031034	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			03/11/2014 12:00:00 AM			PC Approved	03/11/2014 12:00:00 AM	ADDRESS	34.04198	-118.46055	Conversion of (1) retail space into (2) retail spaces.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74854	19041-20000-53360	10101 N BALBOA BLVD	91325	12	204B133   432	2694019002	C2-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Issued	12/26/2019 12:00:00 AM	ADDRESS	34.25429	-118.50256	Replacing existing lights with new LED lights. T-24 ENERGY ONLY. Affected area: 799 SFT (indoor) & 13388 SFT (outdoor) = 14,187 SFT Total.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74855	15041-20000-20980	327 N BOYLSTON ST	90012	1	135A211   216	5160022025	CW	Central	Westlake	Greater Echo Park Elysian		2080.00	Electrical	Electrical	Commercial			07/02/2015 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.06376	-118.25371	Plan check for power and energy. Project scope is a new 121 apartment building. Building is 5 stories. There are 16 typical units: Unit Types A - H, where each typical unit has a version with a loft. Service size is 4000 amps. Zone is a methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74856	12041-20003-01606	1413 E 20TH ST	90011	9	120A211   351	5129005011	[Q]CM-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			07/12/2012 12:00:00 AM			PC Approved	07/12/2012 12:00:00 AM	ADDRESS	34.02162	-118.24853	Changes from previously approved plans.  Change outdoor fixtures and some outdoor lighting fixtures.  Plan check for energy only.Note: Permit issued under a separate permit.*****T24 and emergency lighting plan check only for new one story warehouse building. Service is only 400 amperes.  Original submittal to building plan check is  100' X 160' 1 STORY TYPE III-B SPRINKLERED WAREHOUSE W/ 35' X 75' MEZZANINE AND ROOF TOP PARKING*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74857	15041-20000-40820	1926 N ALVARADO ST	90039	13	144A209   157	5420004018	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2015 12:00:00 AM	12/23/2015 12:00:00 AM		Permit Expired	01/26/2018 12:00:00 AM	ADDRESS	34.08901	-118.25632	Plan check for PV roof monted system. System size: 3.8kW with 19 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74858	14041-20000-02594	16249 W ITASCA ST	91343	12	201B137   778	2677017008	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			01/29/2014 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.24525	-118.48646	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 11KW AC USING 2 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. USING POWER OPTIMIZERS$0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74859	19041-10000-50131	1426 S PALOMA ST	90021	14	121-5A211 101	5132022036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Apartment			12/05/2019 12:00:00 AM	04/21/2020 12:00:00 AM		Permit Finaled	11/30/2020 12:00:00 AM	ADDRESS	34.02881	-118.24943	POWER PC FOR A HOMELESS SHETLER. SCOPE INCLUDE REUSING EXISTING 800 AMP 480Y/277 V 3 PHASE 4 WIRE SERVICE, AND INSTALLATION OF NEW PANELS & RELOCATION OF EXISTING XFMRS. TOTAL AFFECTED AREA  17650sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74860	19041-10000-13247	17461 W REVELLO DR	90272	11	126B117   548	4416021034	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.04053	-118.55677	Plan check for two new Tesla Powerwall betteries (13.5kWH) for a Battery backup system with existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74861	13041-20000-21462	10140 N LEMONA AVE	91345	7	204B149   329	2647002029	RS-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2013 12:00:00 AM			Reviewed by Supervisor	08/20/2013 12:00:00 AM	ADDRESS	34.25504	-118.45853	PV1 TRANSFORMERLESS SYSTEM. 5000 KW SYSTEM. 24 MODULES WITH POWER OPTIMIZERS AND 1 INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74862	13041-20001-34045	14630 W WYANDOTTE ST	91405	6	186B149   789	2218023009	R3-1, [Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Apartment			12/06/2013 12:00:00 AM			PC Approved	02/03/2014 12:00:00 AM	ADDRESS	34.20289	-118.45203	(((Expedite fees)))PV2 MICROINVERTERS. TOTAL SYSTEM SIZE 36KW. 144 MODULES AND MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74863	13041-20000-35018	4011 W JEFFERSON BLVD	90016	10	120B185   826	5050027060	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			12/17/2013 12:00:00 AM	03/03/2014 12:00:00 AM		Permit Finaled	09/11/2014 12:00:00 AM	ADDRESS	34.0257	-118.33977	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING RETAIL. SERVICE UPGRADE TO 600A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74864	12041-10000-15214	701 W CESAR E CHAVEZ AVE #108	90012	1	133-5A213  79	5407014***	C2-2D, C4-2D, R4-1	Central	Central City North	Historic Cultural		2071.00	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	07/10/2013 12:00:00 AM	ADDRESS	34.06107	-118.24412	First time tenant, new restaurant.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74865	16041-10001-33058	20600 W VENTURA BLVD	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			04/03/2017 12:00:00 AM	04/25/2017 12:00:00 AM		Permit Finaled	11/03/2017 12:00:00 AM	ADDRESS	34.16715	-118.58204	PC FOR FIRST TIME TI. FULL POWER. ENERGY ALREADY APPROVED UNDER MASTER AND PERMIT ALREADY ISSUED. THIS IS POWER PC ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74866	18041-10000-43963	718 S HILL ST 3RD FLOOR	90014	14	127-5A209  34	5144014040	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	08/06/2020 12:00:00 AM	ADDRESS	34.04527	-118.25477	PC FOR A TI-FIRST TIME TENANT (POWER AND ENERGY) FOR A  LOW RISE OFFICE BUILDING. 3RD FLOOR. SCOPE INCLUDE NEW CIRCUITS, RECEPTICAL  AND LIGHTING. TOTAL AFFECTED AREA IS 5828 SQ.FTB# 18016-10002-03643	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74867	18041-20001-34470	8985 W VENICE BLVD	90034	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			03/11/2019 12:00:00 AM			PC Approved	03/11/2019 12:00:00 AM	ADDRESS	34.02733	-118.39241	3/11/2019changes to an approved set of plans.  changes to tap feeder size < 25 ft in length.this is plan check only.  Installation of (7) private fleet EV chargers and associated 800A 277/480V distribution to existing 4000A  277/480V service	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74868	16041-20000-39779	11902 N BALBOA BLVD	91344	12	216B133   473	2610002050	C2-1VL	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.46	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.28632	-118.5015	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is lighting with the storage area. Total lighting area = 700 sq. ft.Note: Building application has been created under 16016-20000-26972	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74869	17041-10000-11643	1001 N LAGOON AVE	90744	15	033B205  1168	7420026024	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	04/11/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	33.78283	-118.26742	PC FOR ENERGY. REPLACE (E) FIXTURES WITH (N) LED LIGHT FIXTURES. TOTA L AREA 68700 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74870	15041-10000-23576	964 E 11TH ST	90021	14	123A213    96	5132014035	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/23/2015 12:00:00 AM	07/23/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.03193	-118.24734	T24 ONLY. REMOVE HID LIGHT FIXTURESAND REPLACE WITH NEW LE FIXTURES. TOTAL AREA 1100 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74871	13041-10001-32332	408 N LUCERNE BLVD	90004	4	138B189   153	5523020008	R1-1	Central	Wilshire	Greater Wilshire		1923.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			PC Approved	01/13/2014 12:00:00 AM	ADDRESS	34.07777	-118.32469	Expedited RSES plan check per applicant request.(((PV1, Install 7 kW DC roof-mounted solar array for a 2 story house, interconnect with service panel. Transformered inverter. Fronius IG 5100 NEG. 28 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74872	14041-10000-06425	2379 N EARLS CT	90077	5	153B141   180	4377041046	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/10/2014 12:00:00 AM			Reviewed by Supervisor	03/19/2014 12:00:00 AM	ADDRESS	34.11397	-118.47385	NEW GUEST HOUSE, POOL ARE, AND COURT PAVILION TO EXISTING SFD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74873	14041-20005-20098	5851 W 88TH ST	90045	11	096B169   870	4125009196	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			10/17/2017 12:00:00 AM			PC Approved	10/17/2017 12:00:00 AM	ADDRESS	33.95713	-118.3847	[[ 10/17/17 CHANGE TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 8. CHANGING FIXTURE TYPES AND LANDSCAPE LIGHTING. PLANCHECK ONLY.]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74874	15041-20000-17529	10620 W RIVERSIDE DR	91602	4	165B177   107	2423003004	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Commercial			06/08/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.15204	-118.36227	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 3,720 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74875	14041-20000-18517	23601 W LADRILLO ST	91367	3	171B093   314	2047006009	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	07/21/2014 12:00:00 AM		Permit Finaled	09/22/2014 12:00:00 AM	ADDRESS	34.1659	-118.641	$0 PERMIT FEE DUE TO SENATE BILL 1222 FROM 2012PV1Install roof-mounted solar array on SFD. System size: 12kW.(2) SolarEdge SE6000A-US-ZB-U transformerless inverters(53) SolarEdge P300 power optimizers(53) Trina Solar #TSM-255PA05.18 pv modules	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74876	14041-10001-12860	16750 W VIA PACIFICA	90272	11	138B121    51	4431039002	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.01	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM			PC Approved	06/19/2014 12:00:00 AM	ADDRESS	34.07667	-118.54851	(((EXPEDITE FEES)))PV1 MICROINVERTER PLAN. 400AMP SERVICE AND GROUND MOUNTED SYSTEM. BUILDING PLAN CHECK APPROVAL REQUIRED PRIOR TO ELECTRICAL PLAN CHECK APPROVAL. TOTAL SYSTEM SIZE 8.6KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74877	14041-20000-06960	349 S LOS ANGELES ST Unit C801	90003	14	129A213   147	5148001021	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Expired	07/21/2016 12:00:00 AM	PIN	34.04793173	-118.24587062	T24 FOR EXISTINT RESTAURANT. OCCUPANT LOAD DOES NOT EXCEED 99 AND NEW CONNECTED LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74878	17041-10000-22757	315 W OLYMPIC BLVD	90015	14	127-5A209 251	5139004026	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM			PC Approved	07/21/2017 12:00:00 AM	ADDRESS	34.04202	-118.25873	FULL PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME TENANT FOR BEAUTY  SALON WITHIN CORE & SHELL  AT 1ST FLOOR OF MIXED USE BUILDING. SCOPE INCLUDES CONNECTING TO AN EXISTING DISTRIBUTION BOARD. TOTAL AFFECTED AREA = 2534SQ. FT. PERMIT ALREADY ISSUED - 17041-10000-12224	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74879	12041-20000-10459						A2-1		Northridge	Northridge East	YES		Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			PC Approved	08/02/2012 12:00:00 AM				New PV system for greek church. 141.12 kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74880	18041-10000-36877	10250 W SANTA MONICA BLVD 2930	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Pull plan check for first time  T.I. to retail store, new store front. Scope includes new lighting and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74881	13041-10000-29219	8466 S FIGUEROA ST	90003	8	097-5A201 129	6032035026	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Public Safety Only			10/21/2013 12:00:00 AM	10/21/2013 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	33.96195	-118.28249	NEW FIRE WARNING SYSTEM AFOR 2-STORIES BUILDING/CLASSROOMS; 160 DEVICES ARE PASSIVE DEVICES-SMOKE AND HEAT DETECTORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74882	14041-20001-21959	6901 N TUJUNGA AVE	91605	2	183B173   184	2320002016	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			03/17/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.19626	-118.37921	Changes to approved set.  Addition of 1 combiner box, 1 fusible disconnect switch, 1 non-fusible disconnect switch.  Changes made to grounding system and main breaker.*****Previous Work Description*****PV2.  Install 192 kw roof-mounted, utility-interactive solar system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74883	11041-10000-01335	4553 S GLENCOE AVE	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM	02/03/2011 12:00:00 AM		Permit Finaled	04/15/2011 12:00:00 AM	ADDRESS	33.98415	-118.43328	Title 24 energy for a two story commercial bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74884	17041-10000-31373	19500 W PLUMMER ST SUIT E	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/01/2017 12:00:00 AM	09/14/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.2426	-118.55846	PC FOR NEW FA IN A TI SPACE FOR RETAIL STORE. TOTAL 51 DEVICES AND 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74885	15041-20000-21819	16159 W PARTHENIA ST	91343	12	195B141   711	2672013039	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	04/04/2016 12:00:00 AM	ADDRESS	34.22856	-118.48464	Plan check Title 24 only for outdoor lighting for POPEYES LOUISIANA KITCHEN. Total outdoor lighting area: 2400sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74886	08041-10004-22411	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM			PC Approved	08/15/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to previously approved set of plans.  Revised loads, and add floor junction box.   *****NEW HIGH RISE BUILDING - MEDICAL OFFICE (SHELL ONLY)VARIANCE FOR DEFERRED APPROVAL OF FIRE ALARM SYSTEM WAS SUBMITTED.P/check is approved subject to the ""Conditions of Approval"" on a request for modification regarding campus style feeder to a fire pump.*****"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74887	13041-10000-27656	12000 W HUSTON ST	91607	2	168B165   251	2355010047	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Expired	01/07/2016 12:00:00 AM	ADDRESS	34.15929	-118.39478	PV1.  Upgrade REC 245 PE modules with REC 250 PE modules for (E) roof-mounted solar array.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74888	15041-20000-16402	22320 W PHILIPRIMM ST	91367	3	174B101   213	2146023022	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	06/11/2015 12:00:00 AM	ADDRESS	34.17273	-118.6127	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, and (28) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74889	11041-10000-16742	335 E 2ND ST 105	90012	14	129A215    54	5161017033	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM			PC Approved	08/09/2011 12:00:00 AM	ADDRESS	34.0487	-118.24051	TI TO AN EXISTING SALON.  T-24 OTC PLAN CHECK ONLY.  SUITE 105	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74890	19041-20001-44908	371 S ANDERSON ST	90033	14	127-5A219 340	5172015017	M2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.04262	-118.22584	CHANGES TO AN APPROVED SET OF PLANS, CHANGES INCLUDES THE REVISION OF EMERGENCY LIGHITNG. SEE ALL CHANGES UNDER CLOUDED AREAS.  pc only.Power and lighting for (E) building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74891	11041-20000-12324	1000 N WESTERN AVE # 102	90732	15	021B193   140	7445010041	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	06/15/2011 12:00:00 AM		Permit Finaled	07/22/2011 12:00:00 AM	ADDRESS	33.75242	-118.30869	energy plan check yogurt land	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74892	14041-10000-04684	5148 E LINCOLN AVE	90042	1	154-5A225  15	5478007002	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	1 or 2 Family Dwelling			02/21/2014 12:00:00 AM	03/04/2014 12:00:00 AM		Permit Finaled	03/18/2014 12:00:00 AM	ADDRESS	34.11968	-118.2033	PV1, INSTALL 4.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE SE3800A-US-ZB-U(18) MODULES:  CNADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74893	19041-20000-26854	8652 W LE BERTHON ST	91040	7	207B189    77	2551043004	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland-Tujunga		1032.00	Electrical	Electrical	1 or 2 Family Dwelling			07/12/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.26769	-118.32174	PLAN CHECK FOR NEW ROOFTOP PV SYSTEM AND ESS FOR EXISTING SFD. SYSTEM SIZE IS 7.68KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (24) SILFAB PV MODULES WITH P320 OPTIMIZERS, A SEAUTO-TX-5000 AUTO TRANSFORMER, A SE7600A INVERTER, A LG CHEM RESU10H BATTERY 9.8KWH, AND A 125A LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74894	15041-20000-40303	18828 W STRATHERN ST	91335	3	189B121   247	2103012005	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/28/2015 12:00:00 AM	ADDRESS	34.21552	-118.54355	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 7.6KWac. (28) MODULES-KYOCERA #KU2656ZPA(1)INVERTER-FRONIUS PRIMO 7.6	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74895	15041-10000-34391	12105 W BRANFORD ST	91331	7	204B165   302	2537017009	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	PIN	34.25336293	-118.39701515	PC FOR POWER. SERVICE UPGRADE TO 600 A. JUNK CAR LOT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74896	15041-20000-32016	14107 W BURBANK BLVD	91401	4	174B153   779	2245027040	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			09/28/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.17229	-118.44023	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RETAIL SPACE. 850 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74897	16041-10000-25711	8985 W VENICE BLVD	90232	5	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	07/21/2016 12:00:00 AM		Issued	07/21/2016 12:00:00 AM	PIN	34.02776724	-118.39296613	INSTALLATION OF A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING.3FA  PANELS AND 52 FA PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74898	18041-10001-18748	445 S BUNDY DR	90049	11	132B141   920	4404008020	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2018 12:00:00 AM			PC Approved	08/28/2018 12:00:00 AM	ADDRESS	34.05452	-118.47558	***THIS IS PLAN CHECK ONLY**PC FOR CHANGES TO APPROVED SET. SCOPE INCLUDES CHANGES TO MODULE TYPE FROM 325 TO 320 AND ADDITION OF 1 ADDITIOAL MODULE FOR A TOTAL COUNT OF 43 MODULES. NEW DC SIZE 13.76 KWDCAC WATTAGE UNCHANGED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74899	17041-10001-19990	5615 S MESMER AVE	90230	11	105B165   281	4220006076	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM			PC Approved	01/30/2019 12:00:00 AM	ADDRESS	33.98582	-118.40099	Energy plan check for a lost plan, new service and panels also being updated. Permit fee shall be paid under original application number with a total area of 5,771-SQ FT.       Building permit #15016-30000-02405	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74900	13041-20000-30660	21825 W SHERMAN WAY	91303	3	183B105    79	2111021010	[Q]C2-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.22	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM			PC Approved	11/01/2013 12:00:00 AM	ADDRESS	34.20118	-118.60379	T24 FOR EXISTING RESTAURANT. SCOPE OF WORK IN CORRIDOOR AND STORAGE AREA. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74901	18041-20001-46420	22632 W CALVERT ST pv1	91367	3	177B097   423	2039017016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.18087	-118.62005	02/01/2019 Changes to an approved set of plans. Battery back-up equipment has been removed and PV interconnection configuration has changed. PV system size and equipment has remained the same.*****Original Work Description*****pv1install roof mounted pv system sized 9.4KW AC interconnected with msp with (1) tesla poerwall 5KWh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74902	17041-10000-20752	6036 W COMEY AVE	90034	10	123B173   457	5065012037	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	08/10/2017 12:00:00 AM	ADDRESS	34.03441	-118.37569	$0 permit fee due to senate bill 1222 from 2012PC for rooftop solar for new 16KW system. PC for 51 Solaredge #p400 panels, 1 solaredge SE10000 inverter, 1 solaredge SE6000 inverter and 125A load center. Inspectoion to check that equipment has 75 deg C rated terminals.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74903	16041-20000-22738	5750 W WILSHIRE BLVD 1ST FLOOR	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/28/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	01/04/2017 12:00:00 AM	ADDRESS	34.06227	-118.3542	RENOVATION OF (2) EXISTING TENANT ELEVATOR LOBBIES ON THE GROUND FLOOR.  PLAN CHECK FOR ENERGY. 2798 SQ FTBUILDING PERMIT UNDER 16016-10000-03242	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74904	16041-10000-43273	1940 S TARLETON ST	90011	9	118-5A213  38	5129012015	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.02043	-118.24582	PC for enrgy only. Indoor + Outdoor title 24. Remove HID fixtures and replace with new LED fixtures. Total sqft: 63450	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74905	14041-10000-22884	5518 N KESTER AVE	91411	4	174B149  1026	2249028003	[Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	10/15/2014 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	PIN	34.17085711	-118.45709751	PV1, INSTALL 2.25 ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(9) MODULES: KYOCERA KD250GX-LFB3(1) INVETER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74906	17041-20000-39113	5164 N KNOLLWOOD WAY	91364	3	171B097  1780	2075039007	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2017 12:00:00 AM	11/07/2017 12:00:00 AM		Permit Finaled	02/02/2018 12:00:00 AM	ADDRESS	34.16435	-118.61939	PV1.  Install 4.9 kW roof mounted grid tied PV system with battery backup. (15) modules with 7.6 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74907	15041-10000-04103	307 W 4TH ST	90013	14	130-5A211 156	5149015023	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.04986	-118.24968	Plan check for Powe and Energy, for Restaurant Bar/Lounge. Total area: 6463 sq ft. (power plan check per FY) T-24 code based on 2008	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74908	11041-10000-01381	5060 W RODEO ROAD	90016	10	117B177    10	5046038024	C2-1, P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2197.00, 2360.00, 2362.02	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM	03/04/2011 12:00:00 AM		Permit Finaled	03/21/2011 12:00:00 AM	ADDRESS	34.02015	-118.35387	TENANT IMPROVEMENT IN OPEN RETAIL SPACE OCCUPIED MY MULTIPLE TENANTS-NEW LUMINAIRES AND RECEPTACLESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74909	18041-10000-06112	1390 W 228TH ST	90501	15	045B193   782	7347018075	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.81882	-118.3021	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
74910	15041-10000-25858	5519 W HOLLYWOOD BLVD	90028	13	148-5A193 132	5544005002	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM	07/21/2016 12:00:00 AM		Permit Finaled	12/22/2016 12:00:00 AM	ADDRESS	34.10188	-118.31005	CHANGE OF USE FROM RETAIL TO RESTAURANT.  SERVICE UPGRADE TO 600 AMPS.  PLAN CHECK FOR POWER AND ENERGY. NEW PANELS NEW CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74911	16041-10000-21437	1609 W YOSEMITE DR	90041	14	160-5A225 424	5689008037	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	1 or 2 Family Dwelling			06/17/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.13309	-118.20189	INSTALLING 5832 W DC PV SYSTEM (5000 AC PV SYSTEM). SYSTEM INCLUDES 22 PV MODULES RATED AT 265 W AND 1 5000 W INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74912	15041-20001-28592	8445 N JAMIESON AVE	91325	12	192B129   170	2787011020	RA-1	North Valley	Northridge	Northridge South		1154.01	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2015 12:00:00 AM			PC Approved	09/09/2015 12:00:00 AM	ADDRESS	34.22393	-118.52177	Expedited per customer request.PV1. Install roof mounted PV system sized 8.8 kW. Interconnected with main service panel.(27) SPR 327NE Modules(1) SMA SUNNYBOY SB3800 TL(1) SMA SUNNYBOY SB5000 TL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74913	18041-20000-32674	9681 W HIGH RIDGE DR	90210	5	153B157   341	4384015034	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Expired	09/05/2023 12:00:00 AM	ADDRESS	34.11256	-118.42605	PV1.  Installation of PV roof mounted system with 10.4KW AC with 30 modules, 2 inverters(5.2 kW each), and 40.5 kWh energy storage system.Fee $30.13 due to California Senate Bill 1222 and Senate Bill 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74914	19041-30000-27284	8472 W MELROSE PL STE B	90069	5	141B173   515	5528017025	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM			PC Info Complete	07/16/2019 12:00:00 AM	ADDRESS	34.0834	-118.37568	P.C FOR TITLE 24 TENANT IMPROVEMENT TO (E) RETAIL STORE. TOTAL AFFECTED AREA 950 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74915	19041-10000-30927	4320 W 59TH ST	90043	8	105B181   271	4019010033	R1-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2351.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	33.98696	-118.35088	[E-plan] Installation of 13.5 kWh energy storage system and associated distribution equipment.  (E) PV system on site.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74916	14041-20000-29393	514 S CATALINA ST	90020	10	135B197   816	5502022020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Apartment			10/23/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.06489	-118.29525	PV2 Install roof-mounted solar array on existing apartment building.System size: 22.8kW (11.4+11.4). Inverters have transformers.88 305W pv modules. 4 strings per inverter of 11 modules each.Interconnect with existing 400A MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74917	19041-20001-00996	14240 W MCCORMICK ST	91401	4	171B153   416	2248021027	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			04/17/2019 12:00:00 AM			PC Approved	04/17/2019 12:00:00 AM	ADDRESS	34.16565	-118.44354	4/17/2019changes to an approved set of plans.  changes to relocate house loads to load center.  this is plan check only.((((Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (2) battery back-up units onto an existing PV system.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74918	18041-10000-12925	16648 W SEPTO ST	91343	12	204B137   992	2685013032	RS-1	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2018 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.25168	-118.49538	PC for 7.6kW(ac)/10.8kW(dc) rooftop solar for SFD. Installing 30 modules with optimizers and central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74919	16041-10000-00894	8714 S BARING CROSS ST	90044	8	096A199    72	6038017020	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2403.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	33.95844	-118.2892	PV1, rooftop solar installation 3kW AC system.(10 KU2656ZPA(1) PVI-3.0-OUTD-S-US(1) 125A load center	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74920	19041-20000-44181	20600 W VENTURA BLVD Unit  #A	91364	3	171B109    72	2166013014	(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	Commercial			10/29/2019 12:00:00 AM			PC Info Complete	01/03/2020 12:00:00 AM	ADDRESS	34.16715	-118.58204	Plan check for power and energy (First Time Tenant ) for new lighting 2 new sub-panels inverter. Total area: 3863 sq ft. B#19016-20000-25027	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74921	19041-10000-43292	12617 N BROMONT AVE	91340	7	219B157   208	2513022009	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2019 12:00:00 AM	10/23/2019 12:00:00 AM		Permit Finaled	03/02/2020 12:00:00 AM	ADDRESS	34.29896	-118.42419	New PV1 rooftop installation with a system size 4.225kW DC/ 3.8kW AC central inverter (SE3800H-US), 13 module (HANWHA), 13 opttimizer (P320, and upgraded existing panel of 100A with a new service size of 200A.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74922	13041-10000-30532	5717 W MELROSE AVE	90038	13	141B189   278	5534036017	C2-1D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			10/31/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.0836	-118.32504	Medical office TI in a single-story office building.  Change of use from stores/delicatessen to medical office.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74923	19041-10000-31068	2716 S SEVERANCE ST	90007	9	121-5A201  35	5123003415	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/08/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	08/12/2019 12:00:00 AM	ADDRESS	34.02878	-118.28172	PC FOR A NEW FIRE ALARM SYSTEM SCOPE OF WORK IS A NEW FIRE SYSTEM THAT IS INTERCONNECTED BETWEEN FOUR BULDINGS. BUILDING ONE: HHR BUILDING (HAS A EXISITNG FIRE ALARM SYSTEM) BUILDING TWO: SSH BUILDING(HAS THE NEW FIRE ALARM PANEL) BUILDING THREE:ABX BUILDING, AND THE FOURTH BUILDING IS BUILDING ABA. SCOPE OF WORK INCLUDES A NEW FIRE ALARM PANEL, AND 60 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74924	13041-10000-07265	4550 W PICO BLVD	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Public Safety Only			03/20/2013 12:00:00 AM	03/20/2013 12:00:00 AM		Permit Finaled	05/16/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	a redundant fa system for the ross store to be in compatabil with existing FA system for the 3 levels of the building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74925	18041-20000-16487	14851 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.2946	-118.45499	PV1.  Install 3 kW roof mounted grid tied PV system.  (11) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74926	14041-20000-34081	3410 N LA SOMBRA DR	90068	4	159B181   402	5579025005	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2014 12:00:00 AM			Plans on Hold	04/17/2015 12:00:00 AM	ADDRESS	34.13151	-118.34095	NOTE: Application pending withdrawal.Plan check for a PV1 roof-mounted PV system. System size is 11 kWac and consists of (2) inverters and (53) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74927	12041-10000-16669	13431 W RIVERSIDE DR	91423	4	168B157   230	2359019004	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	Apartment			07/18/2012 12:00:00 AM			PC Info Complete	12/07/2012 12:00:00 AM	ADDRESS	34.15778	-118.42605	PLAN CHECK FOR POWER. NEW SERVICE AND METER SECTION FOR EXISTING APARTMENT BUILDING. ALL SUBPANELS EXISTING TO REMAIN.BUILDING #17	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74928	14041-10000-08096	12256 W MORRISON ST	91607	2	168B165   115	2356011009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			03/26/2014 12:00:00 AM	03/28/2014 12:00:00 AM		Permit Finaled	05/08/2014 12:00:00 AM	ADDRESS	34.16021	-118.40058	PV1 3KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(1) inverters: {SOLAREDGE SE3000A-US}]. [(12)modules: {{Canadian Solar {CS6P 250P}}]SOLAREDGE {POWERBOX 300}	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74929	14041-20001-23017	537 E VENEZIA AVE	90291	11	108B145  1638	4237003009	M1-1	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			08/22/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	33.98952	-118.45973	EXPEDITE FEESpv2 commercial rooftop. total system size 17.8KW AC USING TRANSFORMERLESS INVERTER. USING 2 CENTRAL TRANSFORMERLESS INVERTERS. TOTAL OF 2 SERVICES AND POINT OF INTERCONNECTION. USING A 3PHASE INVERTER AND A SINGLE PHASE INVERTER, 1 FOR EACH SERVICE. 80 MODULES IN TOTAL .	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74930	16041-20001-21782	13451 W GRIDLEY ST	91340	7	222B157   378	2513008035	R1-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2016 12:00:00 AM			PC Approved	07/12/2016 12:00:00 AM	ADDRESS	34.30392	-118.4267	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.6 KW no fees due to senate bill   1222	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74931	15041-10000-10877	8500 S VERMONT AVE BLDG C	90044	8	097-5A199 185	6032013905	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM			Reviewed by Supervisor	04/21/2015 12:00:00 AM	ADDRESS	33.96105	-118.29134	"NEW DEVELOPMENT 1000 AMP SERVICE, CORE AND SHELL,  PC FOR POWER AND ENERGY. THIS IS BULDING 'C' OF 7 BUILDINGS. TITLE 24 ENERGY CALCS FOR COMMON AREAS TO BE SUBMITTED AT A LATER TIME. ENERGY FEES ARE ESTIMATED BY BUILDING LOAD CALCULATIONS. (((PROPOSED  3-STORY RETAIL AND RESTAURANT BUILDING.THIS BUILDING IS KNOWN AS BLDG ""A""  TYPE VA W/ SPRINKLER SUBSTITUTION FOR FIRE RESISTANCE RATING. )))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74932	18041-30000-17411	19524-19534 W CARDIN PL	91324	12	198B117   258	2761035101	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Apartment			05/10/2018 12:00:00 AM	07/25/2018 12:00:00 AM		Permit Finaled	12/20/2018 12:00:00 AM	PIN	34.23808048	-118.559	POWER PLAN CHECK FOR A NEW 6 UNIT TOWNHOUSE BUILDING WITH ATTACHED GARAGES PER EACH UNIT  LOCATED IN AN AREA WITH MULTIPLE SIMILIAR BUILDING . MAIN SERVICE IS 600-AMP. OUTDOOR LIGHTING IS UNDER A SEPARTED PERMIT FOR OVER ALL BUILDING STRUCTURE.REFERENCE APPLICATION #: 15041-20000-43922.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74933	13041-10000-30390	2252 N TRACY TER	90027	4	148-5A205 160	5433017006	[Q]C1-1XL	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2013 12:00:00 AM	12/02/2013 12:00:00 AM		Permit Finaled	03/12/2014 12:00:00 AM	ADDRESS	34.10205	-118.2735	changes to expired plans (but permit not expired yet under application 12041-10000-01368 - mt12/2/2013). addition of a subpanel on the ground level.PV1 5.04KWAC. 240V. microinverter. NONstd. 3story. Roofmount. [(21) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(21)modules: {SHARP 240W ND-240QCJ}]	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74934	11041-10000-23889	11726 W LAURELWOOD DR	91604	2	162B169   619	2369029002	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			11/08/2011 12:00:00 AM	12/08/2011 12:00:00 AM		Permit Finaled	02/29/2012 12:00:00 AM	ADDRESS	34.13963	-118.3877	INSTALLATION OF ROOF-MOUNTED 8.25KW PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74935	10041-20000-11450	8901 N CANOGA AVE	91304	12	195B105   360	2779047020	[Q]MR1-1VL, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			06/16/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.23186	-118.59777	Plan check T-24 Energy for office addition. Permit for adding receptacles/lighting fixtures on existing circuits and (1) misc permit for relocating underground conduits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74936	18041-10003-00126	7735 N WINNETKA AVE	91306	3	189B113  1111	2107022078	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2018 12:00:00 AM			PC Approved	05/11/2018 12:00:00 AM	ADDRESS	34.21153	-118.57129	**Zero fee per California Senate Bill 1222**Supplemental plan check to add LADWP meter due to system size is over 10kW AC and to revise the location of the modules (qty and size remain the same). This is plan check only, permit is covered under master 18041-10000-00126<<NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 44 MODULES (REC SOLAR REC285TP2, 285W), OPTIMIZERS (SOLAR EDGE P320) AND A CENTRAL INVERTER (SOLAREDGE SE11400A-US). SYSTEM SIZE IS 11.4KWac AND 12.32KWdc.Zero PV fees due to senate bill 1222.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74937	11041-20000-18079	12232 W OSBORNE PL	91331	7	207B165   247	2537001032	(Q)RD1.5-1	North Valley	Arleta - Pacoima	Pacoima		1047.02	Electrical	Electrical	Public Safety Only			08/25/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	09/13/2012 12:00:00 AM	ADDRESS	34.26094	-118.39991	New Fire Alarm System for 2 Buildings. FACP on South Building serving North Building (12230)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74938	12041-20000-23712	7080 W HOLLYWOOD BLVD #200	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/04/2012 12:00:00 AM	01/10/2013 12:00:00 AM		Permit Expired	12/04/2015 12:00:00 AM	ADDRESS	34.10134	-118.34445	Change to lighting and receptacles for a Yoga Studio on the 2nd floor of an existing high-rise commercial building.  Load is less than 400 Amps and Occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74939	12041-20001-27445	2054 W PANAMINT DR PV-1	90065	14	151-5A219 218	5462030013	RA-1	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.10892	-118.2254	Changes to approved set of plans. New roof layout, relocation of equipment, and service upgrade.Zoning has been approved on original permit.New 9.8kw rooftop mounted photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74940	12041-10002-16921	1801 S FIGUEROA ST	90015	9	124-5A205 281	5126002008	CM-2-O	South Los Angeles	South Los Angeles	Downtown Los Angeles		2240.20	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM			PC Info Complete	03/25/2014 12:00:00 AM	ADDRESS	34.03524	-118.27179	"(((2/14/2014 CHANGES MADE TO APPROVED SET OF PLANS. SCOPE OF WORK HAS BEEN GREATLY REDUCED. PERMIT HAS ALREADY BEEN PULLED THIS IS A PLAN CHECK ONLY APPLICATION)))PLAN CHECK FOR POWER AND ENERGY FOR NEW 1-STORY BUILDING STRUCTURE W/ MEZZ AT 1ST LEVEL. GROUND LEVEL OFFICE AND SHOW ROOM FOR MERCEDES BENZ DEALERSHIP.  BUILDING IN METHANE ZONE. NEW 3000 AMP SERVICE. 2500A FEEDER SUPPLYING BUILDINGS MERCEDES BENZ BUILDING.  THIS APPLICATION IS FOR  PORTION""B"".  PORTION ""A"" WAS SUBMITTED UNDER 12041-10000-16921."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74941	17041-10002-36884	742 S CLOVERDALE AVE	90036	4	132B181   166	5089002015	[Q]R4-1-HPOZ	Central	Wilshire	Mid City West		2151.02	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.06096	-118.34655	"Changes to an approved set. All changes are clouded under delta ""D""Changes include relocating inverters, AC disconnect, and load center on the roof-layout, and rerouting conduits for trenching."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74942	17041-10001-04636	20215 W RINALDI ST BLDG S4	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.27499	-118.57438	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding landscape lights, ourdoor lights, revising title 24 calculations, and adding landscape floor plans.Note: Somer Permit fees are covered under PCIS# 17041-10000-04636	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74943	16041-10000-43103	6202 N LAUREL CANYON BLVD	91606	2	177B165   324	2334010024	C1-1L, P-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.18322	-118.39629	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total area: 12250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74944	18041-10000-23311	2121 E 8TH ST	90021	14	123A215   138	5166029031	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	09/17/2018 12:00:00 AM	ADDRESS	34.02951	-118.23469	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74945	14041-20000-02322	7412 W 80TH ST	90045	11	099B157   284	4114014015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	03/14/2014 12:00:00 AM	ADDRESS	33.96364	-118.42678	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. 3 STRINGS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74946	17041-10000-04385	1999 S AVENUE OF THE STARS SUITE 200	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	TI TO OFFICE SPACE. PV FOR T24 ENERGY ONLY, NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74947	18041-20000-18461	14844 W CASTILLE WAY	91342	7	219B149   700	2611007051	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2018 12:00:00 AM	05/17/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.29462	-118.45456	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74948	16041-20000-20063	8884 N KEWEN AVE	91352	6	195B165   366	2631030005	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.23069	-118.39346	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74949	18041-20001-42224	16174 W WOODVALE ROAD	91436	5	165B141   463	2285011025	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2018 12:00:00 AM			PC Approved	12/10/2018 12:00:00 AM	ADDRESS	34.14529	-118.4803	Expedite per applicant requestPlan check for PV roof mounted system and Energy Storage System, PV System size: 15.43KW, 17.6kW AC and Energy Storage System size: 54kWh with 49 PV Modules, 2 inverters(10.0kW and 7.6kW) with 4 Tesla PowerWall 2.0 13.5kWh interconnected to 400A Service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74950	14041-10000-14328	9301 N TAMPA AVE #130	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/29/2014 12:00:00 AM	07/17/2014 12:00:00 AM		Permit Finaled	10/14/2014 12:00:00 AM	ADDRESS	34.2392	-118.55379	Title 24 only.  T.I. to existing commercial space in a mall.Total area = 5354 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74951	16041-20003-31717	3850 S CRENSHAW BLVD	90008	10	117B185   775	5033003003	[Q]C2-1, [Q]P-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2342.00	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM			PC Approved	10/26/2018 12:00:00 AM	ADDRESS	34.01602	-118.33474	"10/26/2018 - Reapproval of lost set of plans.  (((TI TO AN EXISTING BUILDING.  REPLACEMENT OF EXISTING PANELS ONE FOR ONE.  ADDITION OF NEW PANEL ""AC"" NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 9905)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74952	13041-10000-25868	718 E 10TH ST	90021	14	124-5A211 169	5132011026	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/19/2013 12:00:00 AM			PC Approved	09/19/2013 12:00:00 AM	ADDRESS	34.03536	-118.25126	TITLE 24 PLAN CHECK ONLY FOR NEW BUILDING. FUTURE RETAIL. 5100 SQFT. EMERGENCY LIGHTING.1 STORY WITH A MEZZANINE . PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74953	16041-20000-33053	5700 W WILSHIRE BLVD Ste 650	90036	4	135B177   580	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/16/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.06218	-118.35303	6th floor office TI.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74954	10041-10001-25281	4020 S MARLTON AVE	90008	8	114B185    92	5032002065	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM			PC Approved	04/22/2011 12:00:00 AM	ADDRESS	34.01159	-118.33819	REVISIONS TO APPROVED SET OF PLANS: NEW PHONE ROOM-NOT AN ITE ROOM; RELOCATING  A FEW LUMINAIRES ; PROVIDE J- BOXES FOR EXIT SIGNS))))))))))))))))))))))Remodel theater.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74955	13041-20001-32067	1011 S GRETNA GREEN WAY	90049	11	129B145  1020	4264023010	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2013 12:00:00 AM			PC Approved	12/23/2013 12:00:00 AM	ADDRESS	34.04606	-118.46981	(((EXPEDITE FEES)))) PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 8KW AC USING 38 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN. 5 STRINGS. 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74956	12041-20001-21192	1835 S SEPULVEDA BLVD	90025	5	126B153   135	4323026019	M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/06/2013 12:00:00 AM			PC Approved	06/06/2013 12:00:00 AM	ADDRESS	34.04494	-118.44233	(((CHANGES MADE TO PREVIOUSLY APPROVED SET OF PLANS. CHANGED 1 FIXTURE TYPE FROM FLUORESCENT TO INCAND. ALL CHANGES HAVE BEEN CLOUDED))) Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74957	15041-20000-30646	20740 PLUMMER ST	91311	12	198B109    48	2748002032	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	PIN	34.24217305	-118.58551034	Titlw 24 plan check only.  Total area = 2,700 sq. ft.   T.I. to existing warehouse space.  New lighting and receptacles.  Location is not hazardous area per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74958	14041-10000-26837	110 E 9TH ST 6TH FLOOR	90015	14	126A209    43	5139001024	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.04107	-118.25479	PLAN CHECK FOR T24 ENERGY. TENANT IMPROVENET FOR CALIFORNIA MARKET CENTER. 6TH FLOOR CORRIDOR. TOTAL AREA 670 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74959	15041-20000-33304	11932 N RICASOLI WAY LOT 6	91326	12	216B109   121	2701078***	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.28965	-118.58466	PV1 SFD. TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN/ TOTAL OF 24 MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74960	14041-20001-01733	10454 N MONTGOMERY AVE	91344	12	207B141   760	2668018020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2014 12:00:00 AM			PC Approved	03/06/2014 12:00:00 AM	ADDRESS	34.26072	-118.48146	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 5KWAC. 3 STRINGS 1 INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74961	17041-10000-41766	599 W 7TH ST	90731	15	015B197   566	7454003026	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Closed	06/05/2023 12:00:00 AM	ADDRESS	33.73766	-118.28991	REMOVE OUTDOOR METAL HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74962	17041-10000-17546	10859 W OXNARD ST	91606	2	177B173  1012	2414005010	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/14/2017 12:00:00 AM	ADDRESS	34.17956	-118.36774	Title 24 plan check.  Remove HID fixtures and replace with LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74963	18041-20001-03058	13286 N RALSTON AVE	91342	7	225B141   161	2501002042	[Q]MR1-1, [Q]P-1	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM			PC Approved	05/28/2019 12:00:00 AM	ADDRESS	34.31344	-118.47347	Revisions to approved set.  Relocation of service equipment and removal of new subpanels from permit scope.  (((PLAN CHECK FOR POWER ONLY FOR NEW SERVICE UPGRADE FROM 400A TO 2000A DISTRIBUTION SYSTEM. PLAN CHECK ONLY INCLUDES UPGRADE WITH INSTALLATION OF 4 NEW PANEL WITH NO NEW LOAD AND CONNECTING EXISTING EQUIPMENT TO NEW SERVICE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74964	12041-10000-30786	12746 W JEFFERSON BLVD Bldg 2	90094		102B161  1167	4211033012							Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	07/15/2013 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	Plan check power and energy for Building 2. Four story office shell on top of common subterranean parking with Building 1, 3, and 4. Service supply from Building 1. Site located in methane zone. Modification to separate fire alarm system has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74965	10041-10000-08629	6340 W HOLLYWOOD BLVD	90028	13	148-5A187 166	5546009026	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/10/2010 12:00:00 AM			PC Approved	05/10/2010 12:00:00 AM	ADDRESS	34.10145	-118.32796	"Change from previously approved plans.  Permit under 10041-10000-04112.  Plan check for energy. ""COMPLY WITH DEPARTMENT ORDER effective date12/28/2005. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74966	18041-20000-45225	10506 W BLOOMFIELD ST	91602	4	165B177   496	2424012011	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	11/28/2018 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.1495	-118.35958	Plan check for PV roof mounted system, system size: 10.08kW DC, 8.99 kW AC CEC with 28 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74967	17041-10000-30789	1640 W WILDWOOD DR	90041	14	159A225   147	5689032010	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1832.22	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2017 12:00:00 AM	08/28/2017 12:00:00 AM		Permit Finaled	10/21/2017 12:00:00 AM	ADDRESS	34.12933	-118.2034	PC FOR PV SYSTEM. ROOF MOUNTED. USING 26 MODULES AND CENTRAL INVERTER RATED 5KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74968	15041-20000-29552	7703 N TWINING WAY	91304	3	189B105   630	2110004016	(T)R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.06	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM	09/14/2015 12:00:00 AM		Permit Finaled	09/22/2015 12:00:00 AM	ADDRESS	34.2102	-118.60424	Plan check for PV roof mounted system. System size: 5.0kW with 20 modules and 1 inverter(5.0kW) Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74969	15041-10000-10575	1731 E DENNI ST	90744	15	033B213   278	7428005020	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/09/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	04/29/2015 12:00:00 AM	ADDRESS	33.78593	-118.24069	IN A WAREHOUSE, REMOVE EXISTING HID LUMINAIRES AND REPLACE WITH LED LUMINAIRESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74970	15041-20000-33188	515 S FLOWER ST #500	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/07/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 in existing high-rise building T.I. Total area: 6,947 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74971	14041-10000-35675	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	02/06/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.07196	-118.24719	Cut over of existing feeders from existing old substations to existing newer substations previously installed as part of an electrical infrastructure upgrade project.  Plan check for power. approved by John per N.M	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74972	11041-10004-19293	380 W WORLD WAY FAN ROOM-NO.8	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM			PC Approved	09/27/2012 12:00:00 AM	PIN	33.94094587	-118.40577128	Renovation and addition to existing Tom Bradley International Terminal building-BRADLEY WEST RENOVATIONS: see sheetsADG-RFI-0140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74973	17041-10000-18970	8560 N AURA AVE	91324	12	192B117    69	2783022023	RS-1	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	06/06/2017 12:00:00 AM		Permit Finaled	07/11/2017 12:00:00 AM	ADDRESS	34.22633	-118.55452	PC FOR PV SYSTEM USING CENTRAL 5KW AC INVERTER AND 21 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74974	13041-10001-09313	19500 W PLUMMER ST SUITE G3	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM			PC Approved	10/01/2013 12:00:00 AM	ADDRESS	34.2426	-118.55846	[[[[[[[[[SUPPLEMENTAL PLANCHECK FOR 13041-10000-09313. DELTA 1 CHANGES ONLY.  CHANGES REQUESTED BY INSPECTOR. CODE SECTION 240.4. CHANGES IN FUSES TO PROTECT THE CONDUCTORS PROPERLY]]]]]]]]FULL PLAN CHECK FOR POWER AND ENERGY FOR NEW TENANT SPACE. EXISTING SERVICE. 800A SWITCHBOARD.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74975	10041-10000-08546	10250 W SANTA MONICA BLVD # 55	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			05/07/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	08/06/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	TENANT IMPROVEMENT - COMBINE EXISTING RETAIL SPACES.  REMOVE DISPLAY, DEMISING WALL LIGHT FIXTURES- INSTALL NEW FLOOR, FIXTURES, CABINETS, FITTING ROOMS AND CASH WRAP.  INSTALL NEW STORE FRONT. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74976	14041-20000-24810	2038 S GREENFIELD AVE	90025	5	126B153   302	4323010009	R1-1	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM	09/10/2014 12:00:00 AM		Permit Finaled	10/16/2014 12:00:00 AM	ADDRESS	34.0436	-118.43674	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP. System size: 6.8kW(1) SMA Sunny Boy  3000TL-US-22  transformerless inverter(1) SMA Sunny Boy 3800TL-US-22 transformerless inverter(30) Trina Solar TSM-250 PA05.05	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74977	18041-20000-18029	20748 W SPRUCE CIR (#77)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.29488	-118.58631	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74978	19041-20000-39862	4926 N LLANO DR	91364	3	168B101   366	2170006075	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2019 12:00:00 AM	10/02/2019 12:00:00 AM		Permit Finaled	10/22/2019 12:00:00 AM	ADDRESS	34.15758	-118.61122	PV1 PLAN CHECK FOR NEW ROOF PV FOR EXISTING SFD. PV SYSTEM SIZE IS 9.24 KW DC/8.509 KW AC. SCOPE OF WORK CONSISTS OF (28) PV MODULES WITH MICROINVERTERS, AND A COMBINER BOX	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74979	14041-20003-00836	1102 W 6TH ST	90017	1	132A207   306	5143024011	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM			PC Approved	08/08/2017 12:00:00 AM	ADDRESS	34.05397	-118.26245	Revisions to approved set of plans to reflect as-built conditions.  Delta-F revisions only (some revisions erroneously marked as delta-5).  Revised transformer, feeder, and motor load ratings throughout.  Reassignment of (7) live-work units to regular dwelling units.  Addition of window motor shades to some dwelling units.  Miscellaneous lighting and power plan revisions throughout.  Relocation of loads on SLD.  (((New 606 Unit mixed use apartment/commercial building.  350,000 sq. ft, with three 3,000 amp services.  <<Engineer to verify fees for FINAL.>>  Variance to separate fire alarm has been paid.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74980	15041-20000-29147	7047 N SUNNYSLOPE AVE	91405	2	183B157   324	2328033009	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	34.19884	-118.42704	Installation of new roof mounted solar PV array.  Total system size = 7.6 kWac.  Central inverter system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74981	16041-10008-35288	19525 W NORDHOFF ST Bldg A	91324	12	198B117   257	2761035016	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Approved	03/26/2019 12:00:00 AM	ADDRESS	34.23567	-118.5584	PC ONLY. Delta 34 changes only to an approved set. Removing lights in closet area (Typical) and adding a water proof receptacle on the balcony when required.Original Scope: ((PLAN CHECK FOR POWER AND TITLE 24.  NEW 6 STORY MIXED USE  APARTMENT WITH 215UNITS.   AND RESTAURANT/ RETAIL CORE & SHELL.  FOUR FLOORS OF RESIDENTIAL OVER TWO FLOORS OF PARKING AND 1 SUBTERRANEAN PARKING LEVEL. THREE NEW SERVICES AT 208 VOLTS EACH - 4000 AMP, 4000 AMP, AND 1600 AMP.  TOTAL AREA = 408,828 SQ. FT.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74982	14041-20001-23856	738 S OGDEN DR 1-12	90036	4	132B177   106	5086021015	R3-1	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			10/21/2015 12:00:00 AM			PC Approved	10/21/2015 12:00:00 AM	ADDRESS	34.0615	-118.35982	10/21/15Changes to an approve set. All changes have been clouded. Changes were made under the single line diagram. House panel was relocated, conductors and conduits have been changed, elevator load has increased, and load calculations were revised.(((Plan check for power and energy for a NEW  12-unit apartment building. 800Amp service.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74983	10041-20000-02248	5570 W WASHINGTON BLVD	90016	10	123B177   238	5063022048	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2184.00	Electrical	Electrical	Commercial			02/09/2010 12:00:00 AM	03/18/2011 12:00:00 AM		Permit Finaled	04/05/2011 12:00:00 AM	ADDRESS	34.03632	-118.36534	Roof mounted photovoltaic system.  Three inverters, and three different type of modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74984	17041-10000-24703	3340 E OPAL ST	90023	14	120A225   213	5190013030	R2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.20	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/21/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.02269	-118.20536	Remove outdoor HID fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74985	13041-10000-15301	3551 S TROUSDALE PKWY # 110	90089	9	120A201    66	5039024016	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/11/2013 12:00:00 AM			PC Approved	06/11/2013 12:00:00 AM	ADDRESS	34.02066	-118.28531	13041-10000-15301pc for energy only. less than 400 A. OFFICE #110 and 2nd floor meeting roomINTERIOR REMODEL OF OFFICE SUITE:  NON-BEARING PARTITION, NEW SUSPENDED CEILINGS, MILLWORK AND INTERIOR FINISH MODIFICATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74986	13041-10000-14077	12182 1/2 W VENTURA BLVD	91604	2	162B165   203	2369004043	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	Commercial			05/30/2013 12:00:00 AM			Corrections Issued	05/30/2013 12:00:00 AM	PIN	34.14304633	-118.39798549	TI to existing retail space in single-story commercial building.  New panels, interior and exterior fixtures, audio system, retail phone and data supply.  Newly connected load < 400A, title 24 plan check for lighting only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74987	15041-20000-19301	7612 N PATRIOT WAY	91405	6	186B145   116	2209034005	(T)(Q)RD2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	1 or 2 Family Dwelling			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	10/21/2015 12:00:00 AM	ADDRESS	34.20903	-118.46478	Installation of new roof mounted solar PV array.  Total system size = 3.6 kWac.  Single inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74988	19041-10000-41176	150 S LA BREA AVE	90036	5	138B181  1100	5513018039	C2-1VL	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			10/10/2019 12:00:00 AM	10/10/2019 12:00:00 AM		Permit Finaled	03/12/2020 12:00:00 AM	ADDRESS	34.07207	-118.34383	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74989	15041-10000-21392	5201 N VAN NUYS BLVD	91403	4	172-5A151 218	2249006020	(T)(Q)C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks, Van Nuys		1288.02	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM			Verifications in Progress	11/05/2015 12:00:00 AM	PIN	34.16536974	-118.44966386	New 109,000 sq. ft. 4-story building for new car sales, auto repair, auto storage for dealer inventory, and customer service lounge.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74990	18041-10000-34098	319 E 2ND ST 115A	90012	14	129A213    10	5161017034	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	34.04929	-118.24098	Change of use to convert a portion of larger retail space (483sf) to Restaurant and interior remodeling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74991	13041-20000-17467	8223 S FIGUEROA ST	90003	8	099B201  1336	6032021012	[Q]R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Apartment			07/02/2013 12:00:00 AM	12/10/2014 12:00:00 AM		Permit Closed	04/14/2016 12:00:00 AM	ADDRESS	33.96368	-118.28297	New 37 unit apartment building.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74992	15041-20000-18006	5215 N CAMPO ROAD	91364	3	171B105   753	2168003020	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	06/29/2015 12:00:00 AM	ADDRESS	34.16361	-118.59851	PC FOR SFD TOTAL SYSTEM SIZE 7.6KW AC USING STANDARD PLAN. TOTAL OF 30 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74993	19041-20000-37631	9664 N PINE ORCHARD ST	91331	7	201B161   969	2624013***	(Q)RD5-1-CUGU, RS-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM	09/19/2019 12:00:00 AM		Permit Finaled	10/11/2019 12:00:00 AM	ADDRESS	34.24553	-118.40971	PV1 PLAN CHECK FOR ADDITION TO EXISTING ROOF SFD PV SYSTEM. TOTAL SYSTEM SIZE IS 13.51 KW DC/12.205 KW AC CEC. SCOPE OF WORK CONSISTS OF ADDING (35) PV MODULES WITH MICROINVERTERS AND REPLACING ALL EXISTING MICROINVERTER MODELS AND ADDING A NEW COMBINER PANEL.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74994	15041-20000-05893	13550 W JUDD ST	91331	7	207B157   418	2619023021	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	03/02/2015 12:00:00 AM		Permit Finaled	09/18/2015 12:00:00 AM	ADDRESS	34.26563	-118.42795	Plan check for a PV1 roof-mounted PV system. System size is 3.4 kWac and consists of (16) modules, and (16) micro-inverters.Note: PV plan submit over the counter  because of B contractor can not pull permit online.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
74995	11041-10000-04048	1055 W WILSHIRE BLVD	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			03/03/2011 12:00:00 AM			PC Approved	03/14/2011 12:00:00 AM	ADDRESS	34.05232	-118.2629	TITLE 24 AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74996	12041-20002-20569	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.24317	-118.50383	Changes to approved set of plans. Addition of disconnect to church and verification of fault current for panels e-1 to e-5. Delta 2 changes. Plan check only.Modification to approved plans.  Changes to feeders, panels, to each building.  Plan check only for DELTA 1.         <<<<Service upgrade at existing building, provide feeder services to two other existing buildings, and install photovoltaic systems to the new service equipment.  plan was approved earlier, but modification were required due to DWP renovation requiements.  Fees for modules were covered under previous submittals (12041-20000-10456)>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
74997	19041-10000-44753	1338 S GLENAVON AVE	90291	11	114B149   558	4244002036	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.00841	-118.45624	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 7.56KW DC  PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US), 24 MODULES USING P400 OPTIMIZERS, AND 2 ESS(TESLA POWER WALL) CONNECTED TO EXISTING 200A SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
74998	10041-10000-22065	171 S LA BREA AVE	90036	5	138B181  1180	5513019039	C2-1VL	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM			PC Info Complete	01/05/2011 12:00:00 AM	ADDRESS	34.07163	-118.34424	Retrofit to an existing methane detection system. Plan check is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
74999	11041-10000-22702	3460 W OLYMPIC BLVD	90019	10	129B189   256	5081026035	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			10/24/2011 12:00:00 AM	12/16/2011 12:00:00 AM		Permit Finaled	03/22/2012 12:00:00 AM	ADDRESS	34.05236	-118.31407	UPGRADE SERVICE, NEW PANELBOARD AND CIRCUITS FOR (E) DOCTOR'S OFFICESREMODEL  (E) DOCTOR'S  OFFICE; RELOCATE  (E) BATHROOM; REMOVE (E) INT STAIR TO (N) EXT STAIR; REMODEL SECOND FLOOR TO PROVIDE  (N) PORCH	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75000	13041-10001-34496	2593 N BEACHWOOD DR	90068	4	154-5A189 271	5585007021	RD2-1XL	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/21/2014 12:00:00 AM	ADDRESS	34.11767	-118.32174	Expedited RSES plan chek per applicant request.{{PV1, Install a 1.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[POWER-ONE # AURORA PV1-3.0-OUTD-S-US] and (6) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75001	14041-20000-17926	8407 N FALLBROOK AVE	91304	12	192B097   579	2005002009	[T][Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			07/02/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.22266	-118.62737	Change of use/occ. group from office to gym, occupancy load greater than 100.  Interior T.I.  Install branch circuits and lighting.  Plan check power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75002	16041-20001-27000	6303 N BAKMAN AVE	91606	2	177B173   137	2336015009	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2016 12:00:00 AM			PC Approved	08/08/2016 12:00:00 AM	ADDRESS	34.18508	-118.37808	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.5 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75003	11041-10001-02289	1900 N MARIANNA AVE	90032	14	135A233    64	5223002006	[Q]RD1.5-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2017.00	Electrical	Electrical	Apartment			03/25/2011 12:00:00 AM			No Progress	06/17/2011 12:00:00 AM	ADDRESS	34.06363	-118.1789	EXISTING SERVICE AND DP, UPGRADE THE RESIDENTIAL UNIT, MATCH EXISTING AIC FROM THE DP FOR PANEL C. ((((( changes of fixtures in bath rooms and bed rooms 3-25-11 less tan 50% work)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75004	14041-20000-10542	6449 N GRAVES AVE	91406	6	180B133   409	2230018011	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	04/22/2014 12:00:00 AM		Permit Expired	05/17/2016 12:00:00 AM	ADDRESS	34.18826	-118.50896	PV1.  Install 4.75 kW roof-mounted PV system, interconnect with main service panel.  Transformerless standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75005	16041-30000-25759	6600 N TOPANGA CANYON BLVD #99C	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for Title 24 only. Project site is a tenant space within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,130 sq. ft.Note: Building application has been created under 16016-40000-16147	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75006	11041-10000-14818	3724 E MISSION ROAD	90031	1	136-5A227  61	5211020021	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1991.20	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	09/15/2011 12:00:00 AM		Permit Finaled	12/08/2011 12:00:00 AM	ADDRESS	34.06862	-118.20047	New 1600A service to exist. bldg. and revise feeders to exist. tenant and house panel. (T. I. plans for new tenant under separate submittal, see PCIS 11041-10000-10082)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75007	19041-10000-45860	4507 E VALLEY BLVD	90032	14	135A231   296	5215021029	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			11/07/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/27/2019 12:00:00 AM	ADDRESS	34.06283	-118.18704	PC FOR ENERGY ONLY. NEW OUTDOOR LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75008	15041-20000-04793	633 W 5TH ST 4th FLR	90071	14	130-5A209 144	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for energy only. Modified lighting in common area restroom and hallway. Total Sqft. 278	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75009	16041-10000-26261	6380 W WILSHIRE BLVD suite #100	90048	5	135B173   876	5088014021	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/26/2016 12:00:00 AM	07/26/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.06348	-118.36826	Plan check for Energy (T-24) only.  TI  of existing office space (no change of use), install new lights and receptacles, new additional load < 400A.  Affected area is 6,830 sf within Suite #100.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75010	13041-10000-35627	2105 W BEVERLY BLVD #117	90026	13	136-5A205 283	5157020***	(Q)C2-1, C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM			PC Approved	12/20/2013 12:00:00 AM	PIN	34.06724213	-118.27036965	PLANCHECK FOR T24 ENERGY ONLY PER INSPECTORS REQUEST. PERMIT PREVIOUSLY PULLED. NOT A PATIENTCARE MEDICAL OFFICE PER APPLICANT. 1364 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75011	10041-10000-01308	4810 W SUNSET BLVD	90027	13	147B197   737	5543017018	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			01/25/2010 12:00:00 AM	02/05/2010 12:00:00 AM		Permit Finaled	09/03/2010 12:00:00 AM	ADDRESS	34.09792	-118.29436	Plan check power and energy for Church of Scientology (Place of assembly).  Additional site lighting and additional elevator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75012	18041-10000-38819	10250 W SANTA MONICA BLVD 2895	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/10/2018 12:00:00 AM	03/14/2019 12:00:00 AM		Issued	03/14/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	FIRST TIME TENANT. NEW RESTAURANT IN SPACE NUMBER 2895 N WESTFIELD MALL.PLAN CHECK FOR POWER & ENERGY. DISTRIBUTION BOAD IS APPROX. 60% FULL. METER READING HAVE BEEN INCLUDED FOR REFERENCE. BLDG PERMIT: 18016-10000-31658	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75013	19041-10000-03089	18321 W CLARK ST	91356	3	174B125   453	2160011030	[T][Q]C2-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM			PC Approved	01/25/2019 12:00:00 AM	ADDRESS	34.16988	-118.53123	T-24, PC FOR ENERGY ONLY. TI FOR AN EXISTING COMMERCIAL BUILDING. SCOPE INCLUDES NEW LIGHTS. TOTAL AFFECTED AREA IS SQ. FT. B#19010-10000-00310	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75014	15041-20003-31569	1457 N VAN NESS AVE	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/24/2017 12:00:00 AM			PC Approved	05/24/2017 12:00:00 AM	ADDRESS	34.09731	-118.31598	05/24/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 6. Changes have been made to power disaggregation system and the recircuiting of the CFSDs, door power supplies, and window-washing receptacles.3/17/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 5 CHANGES HAVE BEEN UPDATED WITH FAULT CURRENT CALCULATIONS. ADDITIONAL CIRCUITS FOR UV LIGHTS HAVE BEEN ADDED. PANELBOADS HAVE BEEN UPDATED.02/08/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 5. There have been removal and relocation of electrical and mechanical equipment.*****Previous Work Description*****Plan check for power and energy. TI to existing  commercial building (5 floors). not a highrise per applicant.  Total sqft. 14,228.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75015	14041-10000-22808	788 E 12TH ST	90021	14	123A211    93	5132012061	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/10/2014 12:00:00 AM	ADDRESS	34.03226	-118.25084	permit to be pulled at EPC counter only. PC for energy only (2013 T24 standards). Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75016	12041-20000-20994	18425 W KITTRIDGE ST	91335	3	180B125   375	2125015003	(T)(Q)R3-1LD	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	Apartment			09/06/2012 12:00:00 AM	03/27/2013 12:00:00 AM		Permit Finaled	08/01/2014 12:00:00 AM	ADDRESS	34.19033	-118.53458	New 77 unit 4 story apartment building.  Plan check electrical, and T-24 lighting indoor and out. A  variance to separate the electrical and fire alarm plan check has been paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75017	15041-10000-05481	600 WORLD WAY TERMINAL 6-LV.3 #622	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	04/09/2015 12:00:00 AM		Permit Finaled	06/22/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	TI TO AN EXISITNG SINGLE STORY COMMERCIAL SPACE.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANELS.  NEWLY CONNECTED LOAD <400 AMPS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 942	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75018	14041-10000-25892	6235 E YORK BLVD	90042	14	153A231    27	5493013023	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.01	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	11/18/2014 12:00:00 AM		Issued	11/18/2014 12:00:00 AM	ADDRESS	34.11518	-118.18309	First time new tenant.  full plan check for power and energy for new Big5. total working area covers 10,368 SQ feet. everything is new except the (2) 400-Amp main services	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75019	17041-20001-37257	18838 W MAPLEWOOD LANE	91326	12	207B121   835	2728031007	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM			PC Approved	11/09/2017 12:00:00 AM	ADDRESS	34.26014	-118.54413	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 11.73KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75020	18041-10000-46794	25500 S VERMONT AVE	90710	15	036B197   839	7413031022	[Q]RD1.5-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2944.10	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	33.79244	-118.29048	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75021	12041-10003-09218	735 S BROADWAY	90014	14	127-5A209  71	5144014031	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			06/10/2013 12:00:00 AM			PC Info Complete	06/10/2013 12:00:00 AM	ADDRESS	34.04448	-118.2543	Plan check power and energy for new 6 live-work units in an existing building. Site locate in methane buffer zone. New 1000A service. Modification to seperate fire alarm plans have been filed. Commercial spaces future.((((((  12-07-12  change of floor plan added receptacle , switch gear relocation. no load change.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75022	13041-20000-15105	6255 W SUNSET BLVD 14TH FLR	90028	13	147A189    22	5546026031	[Q]C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.09815	-118.32564	RENOVATION ON 14TH FLOOR. NEW LIGHTING. PLAN CHECK FOR T24 ENERGY ONLY FOR LIGHITNG IN CORRIDORS, RESTROOMS AND ELEVATOR LOBBY. NEW EMERGENCY LIGHTING. PERMIT TO BE ISSUED UNDER THIS APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75023	18041-10000-11820	12746 W JEFFERSON BLVD	90094	11	102B161  1229	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM	04/02/2018 12:00:00 AM		Permit Finaled	04/30/2018 12:00:00 AM	ADDRESS	33.97756	-118.41709	PLAN CHECK FOR TITLE 24 ONLY FOR SIGN PEMIT - TOTAL AFFECTED AREA = 10 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75024	18041-20001-20399	6921 N VARNA AVE	91405	2	183B157   670	2328016016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.19635	-118.42526	plan chgeck for roof mounted pv system for 8.4kva system - system consist of central inverter solaredge SE7600A-US with 28 modules (p320 optimizers). with battery bck up system rated 9.8kwh	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75025	19041-20000-47179	7054 N SEMRAD ROAD	91307	12	183B089   266	2028032001	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/18/2019 12:00:00 AM		Issued	11/18/2019 12:00:00 AM	ADDRESS	34.19878	-118.65026	PV1. INSTALL 9.920 KW DC PV SYSTEM WITH (32) MODULES/OPTIMIZERS AND (1) INVERTER(SE10000H-US) ON EXISTING PV SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75026	18041-20001-07868	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Apartment			03/29/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.16326	-118.37388	Plan check only for changes to approved set. minor FA device relocation on floor plans. clouded changes only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75027	11041-10000-14514	7149 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/13/2011 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	PIN	33.94386821	-118.41794839	NEW FIRE WATER DELUGE PUMP BUILDING AT LAX.  FULL PLAN CHECK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75028	18041-20000-44789	4922 N AZUCENA DR	91364	3	168B101   373	2170002046	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.15783	-118.61386	PV1.  Install 13.95 kW roof mounted grid tied PV system.  (45) panels with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75029	17041-10000-21159	200 N SPRING ST	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM			Corrections Issued	06/22/2017 12:00:00 AM	ADDRESS	34.05405	-118.24317	PC FOR MODIFICATION TO FIRE ALARAM SYSTEM IN CITY HALL.TOTAL OF 13 DEVICES (12 ADDED AND 1 RELOCATED)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75030	12041-20001-10534	7515 N MASON AVE	91306	3	186B109   409	2113002014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2012 12:00:00 AM			PC Approved	08/07/2012 12:00:00 AM	ADDRESS	34.20698	-118.57991	Revision 1 to the previously approved plans for a roof mounted PV system.  Revision 1 is to removed disconnects at roof junction boxes, install a new 10 foot ground rod with #4 awg copper GEC, upgrade the existing service panel to a new Siemens Solar Ready panel with a 50 ampere 2 pole breaker connected at the line side of the service disconnection means.  Existing permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75031	14041-20000-15879	8221 N BOBBYBOYAR AVE	91304	12	192B093   502	2020019021	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	07/28/2014 12:00:00 AM	ADDRESS	34.21838	-118.63352	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 7.7KW AC USING ENPHASE M215 MICROINVERTER. MICROINVERTER STANDARD PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75032	16041-10000-17436	1925 S CENTURY PARK EAST 15TH FLR	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM			PC Info Complete	05/18/2016 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 15TH FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 16157 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75033	16041-20000-12293	1800 S MENLO AVE	90006	1	126B197   545	5056021009	RD1.5-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	05/22/2018 12:00:00 AM	ADDRESS	34.04121	-118.29048	Install a roof-mounted solar array on a SFD. Interconnect with a 125A MSP.System size: 5kW. Ungrounded system. (18) 280W pv modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75034	13041-10000-26496	8959 N NEVADA AVE	91304	12	195B101    37	2010021009	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2013 12:00:00 AM	10/25/2013 12:00:00 AM		Permit Finaled	12/10/2013 12:00:00 AM	ADDRESS	34.23373	-118.60746	""" $0 permit fee is due to the 2012 Senate Bill No. 1222""PV1. ROOFMOUNTED SOLAR ARRAY. 1STORY HOUSE. NON STANDARD PLAN. SYSTEM SIZE: 13 KW.(52) RENESOLA SOLAR MODULES(2) SOLAR EDGE SE6000A INVERTERUPGRADE TO 225 AMP PANEL"	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75035	10041-20000-13954	13488 W MAXELLA AVE	90292	11	105B153    78	4212004012	[T][Q]RAS4-1-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Apartment			07/20/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	04/18/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	Plan check temp power service and equipment in methane zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75036	15041-10000-30615	1153 S SANTEE ST 2ND;3RD-4TH FLS	90015	14	124-5A209  66	5145021028	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/16/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Closed	01/12/2017 12:00:00 AM	ADDRESS	34.03654	-118.25728	ALTERATIONS IN COMMERCIAL TENANT SPACES ON THE  2ND;THIRD;FOURTH FLOORS; NEW LUMINAIRES AND RECEPTACLESPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75037	11041-10000-17172	3650 W MARTIN LUTHER KING, JR BLVD # 101C	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/15/2011 12:00:00 AM			PC Approved	08/15/2011 12:00:00 AM	ADDRESS	34.01118	-118.33649	REMODELING OF RETAIL STORE- PERFUME GALLERYPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75038	19041-20000-28663	22720 W MARTHA ST pv1	91367	3	174B097   501	2040011026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/13/2019 12:00:00 AM	ADDRESS	34.17265	-118.62192	pv1install roof mounted pv system 9.4KW AC interconnected with msp.(1) tesla ESS rated 5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75039	19041-20000-15688	6025 N CRANER AVE 1-6	91606	2	177B173  1025	2414004013	RD1.5-1	South Valley	North Hollywood - Valley Village	NoHo		1231.04	Electrical	Electrical	Apartment			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Permit Finaled	10/07/2020 12:00:00 AM	ADDRESS	34.18011	-118.36945	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW 4-STORY 4-UNIT APARTMENT BUILDING. SCOPE OF WORK INCLUDES (1) FA PANEL, AND (97) FA DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75040	07041-10001-17830	448 S HILL ST Floors 8&9	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.00	Electrical	Electrical	Commercial			04/03/2012 12:00:00 AM	05/04/2012 12:00:00 AM		Permit Finaled	12/03/2012 12:00:00 AM	ADDRESS	34.04896	-118.25139	Plan check power and energy. Revision to approved plans for As-Built condition. 8th and 9th floors. Existing permit. Additional permit for AC equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75041	14041-10000-16589	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/20/2014 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	33.94221	-118.40701	TI in terminal 4 in LAX.  Plan check for power and lighting.  Total area = 1,200 sq. ft.Provide lighting, electrical distribution, 20 kVA UPS system, and power for 5 renovated spaces used as IT rooms.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75042	17041-10001-19678	3611 S GRAND VIEW BLVD	90066	11	114B153   703	4248026040	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2017 12:00:00 AM			PC Approved	06/19/2017 12:00:00 AM	ADDRESS	34.00865	-118.43436	Expedite fees only.       Installation of new roof mounted solar PV system on eixisting single family dwelling.  Microinverter system.  Total size = 10.25 kWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75043	12041-10002-04905	5105 E YORK BLVD	90042	14	156A225   289	5478001016	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1833.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM	04/20/2012 12:00:00 AM		Permit Finaled	07/13/2012 12:00:00 AM	ADDRESS	34.12115	-118.20447	Supplemental application for power plan check requested by applicant and T24 Energy for New Ice Cream shop.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75044	19041-20001-14502	17431 W VICTORY BLVD	91406	6	180B129   989	2229031006	R1-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.01	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2019 12:00:00 AM			PC Approved	06/27/2019 12:00:00 AM	ADDRESS	34.1869	-118.51322	PLAN CHECK ONLY, SUPPLEMENTAL CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY, CHANGE TO SITE PLAN AND SINGLE LINE, REMOVAL OF A LOAD CENTER, AND A CHANGE TO THE SIGNAGE PAGE AND CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75045	14041-20000-22202	9933 N HANNA AVE	91311	12	201B101    59	2745014021	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2014 12:00:00 AM	08/15/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.25094	-118.60774	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(24) KYOCERA KD255GX MODULES(1) POWER ONE PV1-4.2	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75046	17041-20002-17575	19140 W CHARLES ST	91356	3	168B121   221	2176031007	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2017 12:00:00 AM			PC Approved	07/18/2017 12:00:00 AM	ADDRESS	34.15742	-118.55044	[[[7/18/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. REVISING SINGLE LINE DIAGRAM TO SHOW NEW SERVICE 400AMP SOLAR READY SERVICE PANEL]]]]]PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. SYSTEM SIZE: 11.6 KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75047	15041-20000-43358	923 W BLOOM WALK 309	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/23/2015 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	11/09/2016 12:00:00 AM	ADDRESS	34.0202	-118.28926	TI to existing commercial building (labratory). Plan check for energy only. Adding new lighting including emergency. Total sqft. 508.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75048	16041-10000-40548	5036 S SLAUSON AVE	90230	11	108B161   224	4217028008	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2751.02	Electrical	Electrical	Apartment			11/16/2016 12:00:00 AM	02/03/2017 12:00:00 AM		Permit Finaled	09/18/2018 12:00:00 AM	ADDRESS	33.99408	-118.40734	Plan check for New appartment building 13 units  2 story 800A Service. Total area: 9,145 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75049	19041-10001-12471	4060 W WASHINGTON BLVD	90018	10	126B185   996	5060008004	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2187.01	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM			PC Approved	07/30/2019 12:00:00 AM	ADDRESS	34.03968	-118.32772	Changes to an approved set of plans. All changes are clouded under delta 2. Changes include revising single line diagram to reflect as built. Note: Plant Check Only. Permit fees paid under master.  B#19016-10000-09547	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75050	17041-10000-07340	15350 W SHERMAN WAY STE 240	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.20099	-118.46808	Plan check for Title 24 only in exist space office T.I. Total area: 3,241 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75051	10041-20000-12714	13622 W FOOTHILL BLVD	91342	7	222B157   155	2513006022	C2-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM	07/02/2010 12:00:00 AM		Permit Finaled	08/30/2010 12:00:00 AM	ADDRESS	34.30717	-118.43031	TI IN FOR RESTAURANT. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75052	12041-20000-01857	6600 N TOPANGA CANYON BLVD #1044	91303	3	180B101   822	2139004044	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			01/25/2012 12:00:00 AM	02/09/2012 12:00:00 AM		Permit Finaled	04/09/2012 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24 lighting plan check for remodeled store 1044.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75053	19041-20000-22172	22135 W ROSCOE BLVD LOT #14	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 14.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75054	16041-30000-15836	9200 N OAKDALE AVE 1st Floor	91311	12	198B113   146	2761001091	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/12/2016 12:00:00 AM		Permit Finaled	10/12/2016 12:00:00 AM	ADDRESS	34.23811	-118.56674	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 16,260 sq. ft.Note: Building application has been created under 16016-10000-09203	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75055	17041-20000-08846	734-738 N LA CIENEGA BLVD	90069	5	141B173   308	5528001064	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/20/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.08459	-118.37633	Plan check for energy only. TI to existing retail space (art gallery). New indoor and outdoor lighting (incl. emergency). T24 area: indoor - 1,884sqft; outdoor - 245sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75056	13041-20000-28427	19201 W BERCLAIR LANE	91356	3	165B117    65	2177003017	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.15152	-118.55199	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.7 KW AC USING 22 MODULES. USING ENPHASE MICROINVERTER. M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75057	16041-10000-00903	1013 E 46TH ST	90011	9	112-5A209 184	5108026015	R2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	02/20/2016 12:00:00 AM	ADDRESS	34.00194	-118.25787	PV1, rooftop solar installation 3kW AC system.(19) KU2656ZPA(1) PVI-3.6-OUTD-S-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75058	12041-10000-24579	1918 N AVENUE 51	90042	14	159A225   189	5479021007	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1833.00	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	01/15/2013 12:00:00 AM	ADDRESS	34.12835	-118.20249	PV1 - PLAN CHECK 5.04KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM USING SOLAREDGE TRANSFORMERLESS INVERTER AND POWER OPTIMIZER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75059	19041-30000-24419	444 S FLOWER ST 250	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	11/12/2019 12:00:00 AM	ADDRESS	34.05189	-118.25546	PC (ENERGY ONLY) FOR TENANT IMPROVEMENT TO EXISTING OFFICE SPACE; AREA OF SCOPE 9,623SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75060	14041-20000-20059	12101 W PIERCE ST	91342	7	213B165   501	2531021033	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2014 12:00:00 AM	07/25/2014 12:00:00 AM		Permit Finaled	12/30/2014 12:00:00 AM	ADDRESS	34.27976	-118.39659	PV1Install roof-mounted solar array, interconnect with main panel. System size: 3.6kW(1) Power-One Aurora PVI-3.6-OUTD-S-US-Z-A transformerless inverter(18) Trina Solar TSM-255PA05.18 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75061	13041-20001-27745	1808 S MANTIS AVE	90732	15	012B189   169	7562010014	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2013 12:00:00 AM			PC Approved	10/31/2013 12:00:00 AM	ADDRESS	33.72855	-118.31417	((((((Expedite fees)))))))))((ZONING WAS DONE ON ORIGINAL APPLICATION# 13041-10000-19290))PV1 9kw Xfmr AND XFRMless. 1STORY. nonSTD. ROOFMOUNT.  [ 2 INV: PVI-3.6-OUTD-S-US (transformerless) and PVI-4.6-I-OUTD-X-US-Y (isolated)] [ 36 MOD: TRINA {TSM-250PA05.08}]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75062	19041-10000-33141	515 S FLOWER ST #4860	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.05134	-118.25661	NON-STRUCTURAL TENANT IMPROVEMENT TO REMOVE NON BEARING WALL TO EXPAND (E) OFFICE (SUITE #4860)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75063	13041-10000-36002	523 W 7TH ST	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM	12/31/2013 12:00:00 AM		Permit Finaled	02/21/2014 12:00:00 AM	ADDRESS	34.04717	-118.25611	"INSTALLATION OF NEW FACP + NEW DEVICES TO (E) FIRE ALARM SYSTEM IN RESTAURANT SPACE (""SAVOY DTLA"")."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75064	15041-10000-14200	1515 S COLBY AVE	90025	11	129B149   589	4261001004	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			05/11/2015 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.04559	-118.4537	NEW 8 STORY 56 UNIT APARTMENT BUILDING. FULL PC,  PC FOR POWER AND ENERGY. TI-24 FORMS TO BE SUBMITTED AT A LATER TIME AND FEES PER APPLICANT, PER FRANCIS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75065	14041-10000-29464	444 S FLOWER ST 48th floor	90071	14	130-5A209  94	5151018017	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	11/12/2014 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.05189	-118.25546	TI to (E) commercial office space and private showroom in existing commercial highrise building.  12,500 sq. ft.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75066	18041-20000-25002	7319 N NESTLE AVE	91335	3	186B125   813	2119026007	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM	07/05/2018 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	34.20362	-118.53079	Plan check for PV roof mounted system, system size: 11.4kW AC with 36 modules and 1 inverter(11.4kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75067	13041-20000-14510	2222 S JULIET ST	90007	8	123B197   266	5054022005	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	09/19/2013 12:00:00 AM	ADDRESS	34.0356	-118.29523	PV1 2 STORY TWO FAMILY DWELLING STANDARD PLAN. TOTAL SYSTEM SIZE 5.88 KW. 24 PANELS AND 1 INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75068	19041-10000-52376	5750 W WILSHIRE BLVD 1st Flr	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM			PC Info Complete	04/22/2020 12:00:00 AM	ADDRESS	34.06227	-118.3542	Full Plan Check, Interior for T.I. to an Office area on the 1St Floor. Plan Check for Power & Energy. Scope of work includes new lighting, receptacle load, and panels.  Added Load >400Amp. Affected area: 24,856 SFT. Power Plan check collected on 19041-10003-52376.Building Permit: 19016-10000-40119	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75069	17041-10000-03698	2700 N VERMONT AVE	90027	4	153B193   686	5593002913	OS-1XL	Central	Hollywood	Hollywood United, Los Feliz	YES	9800.09	Electrical	Electrical	Commercial			02/03/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.11803	-118.29221	TI CONVERSION OF EXISTING OFFICE INTO A PUBLIC UNISEX RESTROOM; NEW EXTERIOR ON GRADE CONCRETE STAIRS FOR CONVENIENCE pc for t24 energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75070	19041-10000-13555	11131 W LEMAY ST	91606	2	180B173   351	2319020011	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1232.06	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Issued	05/31/2019 12:00:00 AM	ADDRESS	34.19117	-118.37364	(ePlan)  LADWP Community Solar Program: 2.8 kW AC - 10 solar modules and 10 enphase S280 micro-inverters. 1 circuit. 1 service interconnected as a new service drop 100A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75071	15041-10001-07131	3003 S LA SALLE AVE	90018	8	120B193   429	5053016032	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM			PC Approved	05/20/2015 12:00:00 AM	ADDRESS	34.02708	-118.30549	EXPEDITED RSES PLAN CHECK PR APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75072	17041-20000-18645	3815 N MARFIELD AVE	91356	3	162B121    90	2177042003	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM			Reviewed by Supervisor	06/12/2017 12:00:00 AM	ADDRESS	34.13915	-118.55051	pv1install roof mounyed pv system sized 11.4kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75073	19041-20000-05521	1335 W 37TH PL	90007	8	117B197    76	5040010020	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2226.00	Electrical	Electrical	1 or 2 Family Dwelling			02/15/2019 12:00:00 AM	02/15/2019 12:00:00 AM		Permit Finaled	03/05/2019 12:00:00 AM	ADDRESS	34.02008	-118.29859	PV1.  Install 13.57 kW DC roof mounted grid tied PV system.  (46) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75074	17041-20001-09611	12827 W RANGOON ST	91331	6	198B161   321	2629027012	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			10/09/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	02/27/2024 12:00:00 AM	ADDRESS	34.2376	-118.4132	SUPPLEMENTAL PLAN CHECK, CHANGES TO APPROVED SET, CLOUDED DELTA 7 CHANGES ONLY. ADDITION OF LIGHTS, CHANGE TO T24 SHEETS, CHANGE TO AVAILABLE FAULT CURRENTS, AND LOAD CALCS ON PANELS AND SINGLE LINE.*ORIGINAL*Plan check for power and energy. Project site is an existing commercial building (H-3 occupancy). Project scope is the installation of a generator and new load on existing distribution equipment. Total lighting area = 3,817 sq. ft.Note: Building application has been generated under 17016-20000-06971	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75075	14041-10000-26005	380 WORLD WAY T45-FB	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/22/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Closed	03/06/2015 12:00:00 AM	ADDRESS	33.94373	-118.40888	PLANCHECK FOR T24 ENERGY. SIGN LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75076	19041-10000-52795	5551 W 6TH ST	90036	4	135B181   502	5509005015	(Q)R4-2-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Apartment			12/27/2019 12:00:00 AM			PC Info Complete	08/07/2020 12:00:00 AM	ADDRESS	34.06505	-118.348	Plan check for power and energy for T.I. in 4 buildings. Scope of work is the replacement of all dwelling unit panels, reusing all existing circuits,  and the addition of various subpanels, and a various new distibution equipment, connected to an existing electrical system, total affected area is 431,822 sqft, which covers all four buildings.  Building Permit:19016-10000-40679	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75077	19041-10000-22899	19400 S HARBORGATE WAY BLDG A	90501	15	057B193   127	7351003011	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	07/29/2019 12:00:00 AM		Permit Finaled	12/18/2019 12:00:00 AM	ADDRESS	33.85402	-118.30332	T-24 PLAN CHECK FOR A TI TO A WAREHOUSE (BUILDING A) GENERAL LIGHTING. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 130,075 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75078	17041-30000-07279	19119 W LULL ST	91335	3	186B121    82	2104012005	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.20941	-118.54995	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter and (37) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75079	19041-10000-47297	1546 S ENSLEY AVE	90024	5	135B157   565	4327020008	R1V3-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Expired	03/01/2024 12:00:00 AM	ADDRESS	34.06252	-118.42204	**$0 FEES DUE TO AB 1414 & SB 1222[EPLAN] NEW PV1 ROOFTOP INSTALLATION WITH A SYSTEM SIZE OF 12.6KW DC/ 11.4KW AC, WITH 40 MODULES (HANWHA Q-CELLS), CENTRAL INVERTER (SE11400H), 41 POWER OPTIMIZERS (P400),  AND 3 ESS (TESLA POWERWALL).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75080	16041-20000-37022	1500 N EL CENTRO AVE	90028	13	148-5A189 331	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Closed	01/31/2024 12:00:00 AM	ADDRESS	34.09917	-118.32359	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy only.  total square footage 243 lobby floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75081	18041-10000-06263	550 S HILL ST 23RD & 24T-H FLOORS	90013	14	129A211   117	5149032019	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	04/02/2018 12:00:00 AM		Issued	04/02/2018 12:00:00 AM	ADDRESS	34.04753	-118.25268	tenant improvement in tewo floors of officesPLAN CHECK IS FOR TITLE 24 AND 2 EA EMERGENCY CKTS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75082	15041-10001-30571	1601 W FLORENCE AVE	90047	8	102B193  1254	6015035033	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	Commercial			03/21/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	33.97473	-118.30486	Revision to (original) approved set of plan under delta2 and 3. changing the layout of the panels. Change the homerun layout. rearrange the loads and circuits.Original description:{{{{Full PC. Service upgrade to an exisiting bldg change of use from storage to laundry mat. 800 amps service, pc for power and energy.}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75083	09041-20004-24166	500 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	09/28/2010 12:00:00 AM		Permit Finaled	02/24/2011 12:00:00 AM	PIN	33.94094587	-118.40577128	Changes from previously approved plans.  Changes include adding a new emergency subpanel.  All changes indicate by DELTA 4 as shown on plans.  EPC for power only.*****T.I. /   baggage screening area addition to existing terminal 5 at L.A.X.((((((((((( Revision to previously approved set of plans. all changes noted on the plans.))))))))))))))))))))))))*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75084	16041-10001-06476	8408-8410 W 3RD ST	90048	5	138B173   821	5511032045	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			03/30/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.07292	-118.37356	Changes to approved set, adding emergency lighting only, Changes under delta 1. (((   T24 ONLY. TI TO (E) RESTAURANT TO ADD NEW HANDICAP ELEVATOR TO ACCESS THE SECOND FLOOR. TOTAL AREA 3686 SQ FT.   )))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75085	14041-20000-24110	7919 W 80TH ST	90293	11	096B153   113	4115029010	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Finaled	11/07/2014 12:00:00 AM	ADDRESS	33.9618	-118.43508	PV1.  Install 7.49 kW AC roof-mounted, utility-interactive PV system.  (E) array on site, modules to be rewired, relocated, and remounted to comply with ungrounded system wiring methods.((((((   M.Z.  10-16-14  no fees due to senate bill 1222.)))))))))))))))))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75086	19041-10000-48836	1926 N REDCLIFF ST	90039	13	145-5A205  22	5431024009	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2019 12:00:00 AM	12/03/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.09487	-118.26974	[EPLAN] PLAN CHECK FOR ROOF MOUNTED PV1 SYSTEM CONSISTING OF 20  (PANASONIC) MODULES, 20  (SOLAREDGE P400) OPTIMIZERS, 1 (SE6000H-US) CENTRAL INVERTER, CONNECTED TO A NEW 200A MAIN SERVICE PANEL. SYSTEM SIZE IS 6.60KW DC & 6.00KW AC.MAIN PANEL UPGRADE TO BE PULLED UNDER SEPERATE PERMIT	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75087	18041-20000-03837	6907 W 85TH PL	90045	11	096B161   523	4112002013	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	07/05/2018 12:00:00 AM	ADDRESS	33.9605	-118.41165	Plan check for the addition of (1) Tesla PowerWall to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75088	14041-20000-19751	20725 W QUEDO DR	91364	3	169-5A109  64	2166032041	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			07/22/2014 12:00:00 AM	07/22/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.15919	-118.58501	PV1Install roof-mounted solar array on SFD, interconnect with main panel. System size: 5.59kWMicroinverter standard plan.(26) EnPhase M215-IG microinverters(26) Solar World SW250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75089	17041-10000-35339	1420 N ALVARADO ST	90026	13	141A207   168	5419019025	C2-1L, P-1L	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1956.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.08108	-118.26116	PC FOR OUTDOOR T-24, REPLACE EXISTING FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 24900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75090	14041-10000-18108	1727 N OGDEN DR	90046	4	147B177   178	5551008024	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.10249	-118.35952	PV1 4.845KWdc. 240V. xmfrLESS/Ungnd. NONstd. 2story. Roofmount. [(1) inverters: {PVI-4.2-OUTD-US}]. [(19)modules: {Trina {TSM-255PA05.08}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75091	12041-10000-20337	725 S FIGUEROA ST	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/28/2012 12:00:00 AM	10/09/2012 12:00:00 AM		Permit Finaled	12/13/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	REMODELING OF EXISTING OFFICES ON THE 3RD FLOORPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGE4NCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75092	17041-20000-08599	4636 S LINCOLN BLVD	90292	11	105B153   124	4224014023	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			03/17/2017 12:00:00 AM	03/17/2017 12:00:00 AM		Issued	03/17/2017 12:00:00 AM	ADDRESS	33.98239	-118.44062	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is sign lighting (Toyota pylon sign). Total lighting area = 23 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75093	15041-20001-39136	20438 W ACRE ST	91306	3	195B109   183	2781006019	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM			Reviewed by Supervisor	12/01/2015 12:00:00 AM	ADDRESS	34.22978	-118.57884	EXPEDITE PER APPLICANT REQUEST. ((((PV1. AN ADDITION TO AN EXISTING SOLAR SYSTEM ON AN EXISTING RESIDENTIAL ROOF-TOP. NEW ADDITION IS 3.0KWac.  TOTAL SYSTEM SIZE IS 7.0KWac. (8) MODULES-KYOCERA #KU2656ZPA(1) INVERTER-ABB# PVI-3.0-OUTD-S-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75094	13041-10000-01064	19315 W PARTHENIA ST	91324	12	195B117   192	2783027001	[Q]C2-1VL	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM	12/06/2013 12:00:00 AM		Permit Finaled	05/13/2014 12:00:00 AM	ADDRESS	34.22838	-118.5543	New construction of a McDonalds.  Install new 1000A service.  New panels, branch circuits, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75095	19041-10000-00069	17074 W DEVONSHIRE ST	91325	12	204B133  1023	2694001055	QC2-1VL, QP-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			01/02/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.25731	-118.50527	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR PROPOSED WEIGHTLOSS CONSULTING OFFICE.BUILDING PERMIT # 19016-10000-00019	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75096	10041-20000-15804	7270 W MULHOLLAND DR	90068	4	156A181   677	5572001008	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1437.00, 1941.00	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	02/02/2011 12:00:00 AM	ADDRESS	34.11982	-118.35067	PV SYSTEM SERVICE UPGRADE TO 600A UNDER OTHER SUBMITTAL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75097	18041-20001-25174	7343 N TYRONE AVE	91405	2	186B153   889	2217001161	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.2043	-118.44457	8/21/2018changes to an approved set of plans.  changes to add eight modules and increase inter size to 7.6KW AC.(((Plan check for PV roof mounted system, System size: 5.2kW with 16 modules  and  1 inverter(5.2kW))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75098	16041-10000-09353	2433 E HUNTER ST	90021	14	121-5A217 142	5168031015	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/17/2016 12:00:00 AM	03/17/2016 12:00:00 AM		Permit Finaled	09/28/2016 12:00:00 AM	ADDRESS	34.02772	-118.22874	SERVICE UPGRADE TO 800A TO AN EXISITNG WHOUSE BUILDING. ALL PANELS ARE EXISTING. PC FOR POWER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75099	14041-10001-31674	10837 N RATHBURN AVE	91326	12	207B125    81	2715004027	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2014 12:00:00 AM			PC Approved	12/04/2014 12:00:00 AM	ADDRESS	34.26753	-118.533	PV1 roof-mounted 10KW system including (2) Solaredge SE5000, (43) REC260 module and power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75100	11041-10000-20088	1290 S LA CIENEGA BLVD	90035	5	129B173    20	5087003001	C4-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			09/21/2011 12:00:00 AM			PC Approved	09/27/2011 12:00:00 AM	ADDRESS	34.05352	-118.37593	TI TO AN EXISTING RETAIL SPACE.  PLAN CHECK IS FOR ENERGY ONLY, NO EMERGENCY LIGHTING PER APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75101	17041-10000-20161	1651 S SANTA FE AVE	90021	14	120A217    25	5167010008	M3-1-S-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			06/15/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	12/14/2017 12:00:00 AM	ADDRESS	34.0246	-118.23013	PC FOR T24 ENERGY ONLY. REPLACE LIGHTING FOR LED TYPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75102	18041-10001-21861	16951 W ESQUIRA PL	91436	5	168B133   505	2289031008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM			PC Approved	06/29/2018 12:00:00 AM	ADDRESS	34.15345	-118.50265	16.3 (DC) KW PV SYSTEM, WITH 50PV MODULES & 2 INVERTERS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75103	19041-20000-15608	2935 1/2 N DENBY AVE	90039	13	150B213   851	5442022006	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/29/2019 12:00:00 AM	04/29/2019 12:00:00 AM		Issued	04/29/2019 12:00:00 AM	ADDRESS	34.10423	-118.24359	Plan check for a PV1 roof-mounted PV system. System size is 1.68 kWac and consists of (7) modules, (7) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75104	16041-20000-40971	21300 W LEMARSH ST	91311	12	204B105   487	2747009040	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	03/30/2017 12:00:00 AM	ADDRESS	34.25529	-118.59537	pv1install roof mounted pv system (acm) sized 6.7kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75105	17041-10000-32905	3620 S MCCLINTOCK AVE 9TH FL	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.0213	-118.28935	PC for power and energy for office/lab TI. Total of 2241sqft. Area includes blood draw rooms. Installing new 125A panel , circuits, equipment, receptalces and lights.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75106	17041-10001-11000	6606 N VARIEL AVE	91303	3	180B105    44	2148029009	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.03	Electrical	Electrical	Apartment			04/04/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	08/20/2021 12:00:00 AM	ADDRESS	34.19029	-118.59257	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 6. CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM, LOAD CALCULATIONS, AND PANELS SCHEDULES. REVISING SERVICE/DISTRIBUTION BOARD SIZE TO A 3000A 480V/277V 3 PHASE 4 WIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75107	13041-20000-22095	7415 N DELCO PL	91306	3	186B109   618	2114009026	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.20517	-118.57926	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 9.065 KW. 37 PANELS AND 2 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75108	18041-10000-34326	2936 N MONTCALM AVE	90046	4	156B177   219	2427010001	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	12/19/2018 12:00:00 AM	ADDRESS	34.12436	-118.3544	(2)NEW TESLA BATTERY STORAGE SYSTEM(13.5 KWH, 5KWAC) FOR BACK UP LOADS IN A SINGLE FAMILY RESIDENCE. TOTAL SIZE IS 27KWH 10KWAC. PV SYSTEM IS EXISTING UNDER SEPARATE APPLICATION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75109	19041-10000-53766	11940 W LOUISE AVE 1-11	90066	11	111B157  1089	4233018012	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			12/30/2019 12:00:00 AM	10/22/2020 12:00:00 AM		Permit Finaled	06/10/2022 12:00:00 AM	ADDRESS	33.99701	-118.42029	FULL PC FOR A NEW APARTMENT. SCOPE OF WORK INCLUDES A NEW 800A SERVICE FEEDING A NEW 1000A SWITCHBOARD WHICH FEEDS 13 SUBPANELS AND A 15HP ELEVATOR. TOTAL AFFECTED AREA 10,128 SQFT.**********************************************************************(N) 120' x 48' Three Story Eleven-Unit Fully Sprinklered (NFPA 13) Apartment Building (Type VA Construction) with Basement Garage (Type IA Construction).BUILDING PERMIT #18010-20000-02247	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75110	18041-20001-15867	6421 E YORK BLVD	90042	14	153A233   120	5493015017	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.03	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM			PC Info Complete	04/19/2019 12:00:00 AM	ADDRESS	34.11432	-118.18069	plan check only for lost approved set of plans, plan check for power and energy, project is new commercial building (restaurant). Work include 600A Service and a toal lighting area: 8,887 sq ft. B#18010-20000-01843	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75111	11041-10000-17129	5583 N RESEDA BLVD	91356	3	174B125   396	2160004070	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/12/2011 12:00:00 AM			PC Approved	08/12/2011 12:00:00 AM	ADDRESS	34.17208	-118.53629	TI TO AN EXISTING 7-ELEVEN.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75112	16041-20001-02466	11707 W EL CERRO LANE	91604	2	159B169   464	2381002013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2016 12:00:00 AM			PC Approved	02/04/2016 12:00:00 AM	ADDRESS	34.13151	-118.38799	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (2) inverters, (32) inverters, and (1) load center. System is interconnecting with a 400-amp MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75113	15041-20000-08454	14338 W SAN JOSE ST	91345	7	207B153   667	2617012004	RS-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2015 12:00:00 AM	03/23/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	34.26297	-118.44548	Plan check for PV1 roof mounted system with 6kW system and 29 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75114	11041-10000-06542	16633 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			04/01/2011 12:00:00 AM			PC Approved	11/21/2011 12:00:00 AM	ADDRESS	34.22269	-118.49516	T-24 ONLY FOR 120,000 SQ. FT. WAREHOUSE.  PERMIT IS ALREADY PULLED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75115	17041-10000-12211	5716 W JEFFERSON BLVD	90016	10	120B173   311	5047018002	M1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/14/2017 12:00:00 AM		Permit Finaled	05/23/2017 12:00:00 AM	ADDRESS	34.02582	-118.36876	PC for energy only, Indoor/Outdoor Title-24. Remove HID and Install new LED fixtures. Area: 39,900sqft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75116	16041-20000-44970	900 N NORTH SPRING ST	90012	1	135A215   136	5409007003	UC(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Apartment			12/28/2016 12:00:00 AM			PC Info Complete	12/04/2019 12:00:00 AM	PIN	34.06411857	-118.23468941	Power and lighting for new mixed use development with 1600A 4160V 3ph-3w service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75117	17041-30001-41178	12078 W SUMMIT CIR	90210	2	156B165    22	2382017016	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM			PC Approved	11/25/2017 12:00:00 AM	ADDRESS	34.12707	-118.40069	Expedite per applicant requestPlan check for PV roof mounted system. Total sysem size: 19.8kW with 55 AC modules connected to 300A Service MSP	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75118	15041-20000-06584	5348 N VELOZ AVE	91356	3	171B121   142	2161014005	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.16786	-118.53984	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derating main to 175A.System size: 3kW (note: there is an existing 4kW system on the roof, so total amount of solar on roof is 7kW. This permit to only cover 3kW system). Ungrounded system. (13) 260W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75119	16041-10000-02192	695 S WESTERN AVE	90005	10	132B193   275	5093005034	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			01/21/2016 12:00:00 AM			PC Info Complete	03/30/2016 12:00:00 AM	ADDRESS	34.06016	-118.30935	TI on (E) McDonalds, Exterior alterationinstall new lights. PC for Energy only, total indoor area: 2,353 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75120	18041-10000-19504	19400 S WESTERN AVE 1ST FLR	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	33.8552	-118.30917	TI IN AN EXISTING OFFICE AREA ON THE FIRST FLOOR.T-24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75121	13041-10000-27435	257 S SPRING ST 1-51	90012	14	130-5A213 202	5149008***	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			10/03/2013 12:00:00 AM	08/14/2014 12:00:00 AM		Permit Finaled	10/20/2015 12:00:00 AM	ADDRESS	34.05068	-118.24692	PHASE I: TENANT IMPROVEMENT TO (E) RESTAURANT AT FIRST FLOOR.  CONVERT (E) ATRIUM INTO RESTAURANT SPACE. ADDED LOAD IS LESS THAN 400APLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75122	18041-10000-34313	10700 N BALBOA BLVD	91344	12	207B133   457	2683023020	CR-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			09/07/2018 12:00:00 AM	04/11/2019 12:00:00 AM		Permit Finaled	12/02/2021 12:00:00 AM	ADDRESS	34.26494	-118.50209	PC FOR POWER AND ENERGY FOR A NEW 1000A SERVICE 120/208, 3-PHASE WITH 14 SUBPANELLS. ADDITION TO AN EXISTING BUILDING B# 14014-10000-00724	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75123	14041-10000-05247	10700 N BALBOA BLVD 101-102	91344	12	207B133   456	2683023020	CR-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Expired	09/26/2018 12:00:00 AM	ADDRESS	34.26494	-118.50209	CHANGE OF USE FROM MEDICAL SPACE TO RETAIL BUILDING. NEW (5,104 SF) TO (E) MEDICAL BLDG. NEW SERVICE, PANELS, CKTS, & LIGHTING. EPC IS POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75124	10041-10000-12890	120 N ROBERTSON BLVD	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.00	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	07/06/2010 12:00:00 AM		Permit Finaled	08/06/2010 12:00:00 AM	ADDRESS	34.07585	-118.38356	TI in an existing office. Plan check for T24 and emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75125	11041-20001-12539	1638-1640 N LAS PALMAS AVE	90028	13	148-5A185 182	5547014041	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/06/2012 12:00:00 AM			Re-Activate Application	01/06/2012 12:00:00 AM	ADDRESS	34.10082	-118.33601	revise energy calc'schange lighting fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75126	15041-10000-37545	11924 N RICASOLI WAY	91326	12	216B109    55	2701078001	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.28928	-118.58457	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(20) SUNPOWER SPR-X20-250 MODULES(1) SUNNYBOY SB5000 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75127	15041-20000-35839	1350 S UNION AVE	90015	1	127-5A203 225	5135022025	RD1.5-1-HPOZ	Central	Westlake	Pico Union		2242.00	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	12/08/2015 12:00:00 AM	ADDRESS	34.04331	-118.27757	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP.  TOTAL SYSTEM SIZE IS 2.75KWac. (11) MICROINVERTERS-ENPHASE M250(11) MODULES-LG300N1C-A3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75128	19041-10002-23651	6201 E STRICKLAND AVE	90042	14	159A231   299	5482007018	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2019 12:00:00 AM			PC Approved	11/21/2019 12:00:00 AM	ADDRESS	34.12826	-118.18489	PLAN CHECK ONLY. CHANGES TO APPROVED SET. RELOCATING THE SERVICE PANEL AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75129	16041-10000-45166	1000 S GRAND AVE	90015	14	127-5A209 199	5139009015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	02/05/2018 12:00:00 AM	ADDRESS	34.04258	-118.26079	PC FOR POWER AND ENERGY. NEW RETAIL SHOWROOM, PET GROOMING. FIRST TIME TI. CONNECTED LOAD < 400A. TOTAL AREA 3213 SQ FT.B# 16016-10000-30810	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75130	12041-10000-21119	7446 N DARNOCH WAY	91307	3	186B089   457	2027024025	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2012 12:00:00 AM	10/30/2012 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.20498	-118.6471	PV1. INSTALLATION OF  A  11.4KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM. PERMIT INCLUDES SERVICE PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75131	13041-20000-09921	13350 W SHERMAN WAY	91605	2	183B157    86	2328025026	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	Commercial			04/17/2013 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	08/13/2014 12:00:00 AM	ADDRESS	34.20101	-118.42426	Full plan check for first time tenant. Restaurant. Drunken Crab.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75132	17041-10000-37318	6710 W VALMONT ST	91042	7	202-5A203   8	2570007016	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.20	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2017 12:00:00 AM	11/29/2017 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.25158	-118.27846	Pv1, Roof mounted solar system to a single family dwelling. System is using (38)AC modules. Total kw is 13.1.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75133	15041-20003-07849	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			09/04/2015 12:00:00 AM	09/09/2015 12:00:00 AM		Permit Finaled	05/10/2016 12:00:00 AM	ADDRESS	34.12774	-118.26247	09-04-2015 Change to an approved set of plans. Changes include relocation of hearing booths and alter lighting for photo center. Changes apply to Delta 6 only. **************************************************************08/05/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 5. Changes include the addition of  receptacles and lights onto existing circuits.*****Previous Work Description*****Change to approved set. Plan check for Addition of 2  new hearing exam booths to Costco. No light is being add to the 2 new booth; light is part of the booth. {{{{{{PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COSTCO OPTOMETRY ROOMS. NOT A MEDICAL ( CONSULTATION ONLY) 615 SQFT.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75134	16041-10000-15474	9301 N TAMPA AVE SPACE 175	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	08/05/2016 12:00:00 AM		Permit Finaled	11/28/2016 12:00:00 AM	ADDRESS	34.2392	-118.55379	PC FOR ENERGY ONLY. TI FOR RETAIL STORE I NORTHRIDGE MALL(BATH & BODY WORKS). TOTAL AREA 4999 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75135	18041-20000-30117	20224 W BENTLEY WAY	91326	12	213B113   375	2701087011	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.28247	-118.57485	Plan  check for PV roof mounted system, system size: 15.2kW with 40 modules and 2 inverters(7.6KW AC each) connected to existing 400A Panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75136	15041-20000-01382	1440 N SOTO ST	90033	14	133-5A227 137	5202014006	RD1.5-1	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	1 or 2 Family Dwelling			01/16/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Finaled	06/16/2015 12:00:00 AM	ADDRESS	34.05986	-118.19938	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.4KW INTERCONNECTED WITH MSP.(16) HYUNDAI HEAVY INDUSTRIES M250MG MODULES(16) ENPHASE MICROINVERETER M215	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75137	17041-10000-30913	6080 W CENTER DR	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM			PC Info Complete	10/23/2017 12:00:00 AM	ADDRESS	33.97713	-118.39172	PC for energy for office TI to 7th floor. Intalling new circuits, receptacles, lights and one new panel. Total area of 6969 sqft. Building# 17016-10000-24660.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75138	15041-20000-37492	13431 N BORDEN AVE	91342	7	225B149   103	2502030001	RA-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Finaled	12/29/2015 12:00:00 AM	ADDRESS	34.31614	-118.4547	Plan check for a PV1 roof-mounted PV system. System size is 7.6 kWac and consists of (1) inverter, (29) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75139	17041-10000-13425	2535 N CARMAN CREST DR	90068	4	153B181   238	5572009024	RE15-1-H	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2017 12:00:00 AM	06/12/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.11506	-118.34821	Installation of new ground mounted solar PV array interconnected to existing single family dwelling.  Microinverter system.  Total system size = 18 kWac.     Building permit #17020-10000-00561	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75140	14041-20000-30964	13652 W PAXTON ST	91331	7	210B157   585	2619005004	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2014 12:00:00 AM	11/07/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	34.27035	-118.43045	pv1install roof mounted pv system sized 3.4kw interconnected with msp.(16) hyundai m-250 modules(16) enphase m215 microinverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75141	18041-20000-48381	611 S WESTERN AVE	90005	10	135B193   910	5503031006	C2-2	Central	Wilshire	Wilshire Center-Koreatown		2117.04	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	01/13/2020 12:00:00 AM	ADDRESS	34.06305	-118.30927	T24 PLAN CHECK FOR EXISTING RESTAURANT TOTAL SQFT'G = 8042	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75142	13041-10001-35291	5161 N LANKERSHIM BLVD STE #130	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.16452	-118.37469	Delta-1 revisions to approved set: changes to fixture types and proposed install locations.  (((T24 PART 6 ENERGY FOR (E) OFFICE SPACE, LOW-RISE. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING WORK IS APPROX. 2275 SQ FT. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL PLAN CHECK COUNTER.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75143	15041-20001-02105	226 N LARCHMONT BLVD	90004	4	138B189   556	5515025021	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			05/18/2015 12:00:00 AM			PC Approved	05/18/2015 12:00:00 AM	ADDRESS	34.07552	-118.32343	Plan check for change to approve set of plan. Changes include title 24 forms completed for Indoor Lighting Controls.  [[[[[[[PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RITE AID. NEWLY CONNECTED LOAD < 400 AMPS. 9000 SQFT.]]]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75144	10041-10000-00238	7015 W MELROSE AVE	90038	5	141B181   584	5525008006	C4-1XL	Central	Hollywood	Greater Wilshire		1919.00	Electrical	Electrical	Commercial			01/06/2010 12:00:00 AM	02/03/2010 12:00:00 AM		Permit Finaled	11/17/2010 12:00:00 AM	ADDRESS	34.08357	-118.34329	T-24 and emergency lighting plan check for restored restuarant.  The question of the address of the space must be determined.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75145	14041-10000-25751	1900 S AVENUE OF THE STARS	90067	5	132B161    22	4319002056	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05979	-118.41671	plan check for energy only 2013 standards. high rise. emergency lighting installed. ground floor. BLDG#14016- 10 - 18876: TENANT IMPROVEMENT FOR AN EXISTING BANK  IN (E) HIGH RISE OFFICE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75146	15041-10000-04145	12612 N KENNY DR	91344	12	219B137    27	2609019025	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	04/13/2015 12:00:00 AM	ADDRESS	34.29921	-118.49866	PV1 Standard Plan, 5KW AC roof-mounted system including (1) PowerOne PVI -5000-OUTD inverter, and (20) SunPower SPR-327NE-WHT modules.Applicant insists to have plan check over the counter due online service restrict payment process.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75147	19041-20000-19437	8424 W MELROSE PL	90069	5	141B173   504	5528017035	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			05/22/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.08342	-118.37421	T24 plan check for TI to existing commercial space. Installation of lights and outlets only. Total square footage = 1484 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75148	19041-20000-50723	7110 N SHOSHONE AVE	91406	6	183B129   264	2228025018	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.19957	-118.5162	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 11.9 KW DC/10.81 KW AC CEC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75149	18041-20002-19629	8201 N TOPANGA CANYON BLVD	91304	3	189B101     6	2012031017	P-1VL, [Q]C1-1VL, [Q]C1.5-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.04	Electrical	Electrical	Commercial			12/14/2018 12:00:00 AM			PC Info Complete	12/14/2018 12:00:00 AM	ADDRESS	34.21793	-118.6063	12-14-2018 Changes to an approved set of plans, Changes include addition sump pump and circuit reconfigured. All Changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75150	12041-10000-27697	6364 W HOLLYWOOD BLVD	90028	13	148-5A187 170	5546008019	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			11/16/2012 12:00:00 AM	11/16/2012 12:00:00 AM		Permit Finaled	03/15/2013 12:00:00 AM	ADDRESS	34.10144	-118.32866	GENERAL T.I. TO (E) BAR.  MOVE BAR COUNTER, MOVE RESTROOMS, REMODEL ENTRY/MEZZANINE.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75151	16041-10000-05608	11700 N CORBIN AVE	91326	12	216B113     1	2701002068		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			02/17/2016 12:00:00 AM			PC Approved	03/14/2016 12:00:00 AM	ADDRESS	34.28162	-118.57177	PC FOR ENERGY ONLY. NEW GUARD HOUSE W/2 PORTE COACHERS EACH SIDE ENTRY BOOTH #1, ENTRY #2. TOTAL AREA 3364 SQ FT.PERMIT WAS ALREADY PULLED UNDER APP# 16041-10000-04501	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75152	13041-10001-33094	1847 W 43RD ST	90062	8	114B193  1239	5022006011	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.00561	-118.31298	][][EXPEDITED PER APPLICANT REQUEST ][][]PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 125A MAIN IN A 2-STORY HOME. non-standard plan. SYSTEM SIZE IS 3.75 kW DC, & transformerless, with power (15) optimizers (Solaredge #OP250-LV-MC4SM-2NA-Z).  The following components/equipment are used:(15) Trina solar #TSM-250PA05.18(1) Solaredge #SE3800A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75153	17041-10000-38263	2513 E 7TH ST	90023	14	123A221    12	5189009049	RD1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	Commercial			10/24/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.03214	-118.21634	Remove HID fixtures and replace with new LED fixtures  T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75154	17041-10000-37191	13626 W VANOWEN ST	91405	2	180B157    13	2329001038	[Q]C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/17/2017 12:00:00 AM		Issued	10/17/2017 12:00:00 AM	ADDRESS	34.19375	-118.42986	REPLACING OUTDOOR HID LUMINAIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75155	08041-10005-23952	110 N GEORGE BURNS ROAD	90048	5	138B169   208	4334006008	[Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM			PC Approved	09/24/2010 12:00:00 AM	ADDRESS	34.07564	-118.38149	Plan check power and energy for TI of Cedars-Sinai Research Facility.  Existing service, new panels, new equipments, and ckts.  Fire alarm variance was submitted. (((((((((((((((((( CHANGES MADE TO PREVIOUSLY APPROVED SET. REFER TO ALL CLOUDED AREAS IN BLUE  INK AND TITLE 24 , EMERGENCY LIGHTING.)))))))))))))))))))))))) (((((((((( per inspector's correction notice remove one future equipment off of plans. 9-24-10))))))))))))))))))))))))))).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75156	18041-20003-28730	2732 W LOCKSLEY PL	90039	4	151-5A207 185	5438018021	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM			PC Approved	10/09/2018 12:00:00 AM	ADDRESS	34.10749	-118.26237	Revision to approved set.  Change of module power rating from 320W to 315W.  $0 plan check fee per State Senate Bill SB 1222 as amended and extended by State Assembly Bill AB 1414.  (((Plan check for PV roof mounted system, system size: 7.6kW with 24 pv modules and 2 inverters(3.8kW))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75157	18041-10000-13525	21339 W SATICOY ST	91304	3	186B105   144	2109031017	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			04/12/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.20845	-118.59703	REPLACE INDOOR-OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75158	13041-20000-34244	1462 N LACHMAN LANE	90272	11	135B121    83	4420031001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2013 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.0621	-118.54941	"PV1 FOR INVERTER/CHARGER WITH COMBINERS AND CHARGE CONTROLLERS. THIS SYSTEM ALSO CONSISTS OF A BATTERY BANK. TOTAL SYSTEM SIZE 8KWAC.""$0 permit fee due to senate bill 1222 from 2012"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75159	18041-10001-43085	14522 1/2 W VENTURA BLVD	91403	4	166-5A151 137	2276001005	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	PIN	34.15075871	-118.44960626	Suppl App for changes to approved plans.T-24 Energy only for an existing resturant. area is 650sq-ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75160	17041-30000-28917	11150 W OLYMPIC BLVD STE 100	90064	5	126B153   880	4322024038	M2-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			08/15/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.03956	-118.43857	Plan check for title 24 only  T.I. to existing bank alterating, new lighting and receptacle. Total area: 970 sq ft.  load is less than 400A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75161	13041-10000-32863	13106 W TONOPAH ST	91331	6	195B161   627	2627020019	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM	02/18/2014 12:00:00 AM		Permit Finaled	03/13/2014 12:00:00 AM	ADDRESS	34.22877	-118.41759	PV1 9.5KWdc. 240V. xmfrLESS/Ungnd. NONstd. 1story. Roofmount. [(2) inverters: {SOLAREDGE SE3800A-US, SOLAREDGE SE5000A-US}]. [(38)modules: {Renesola {JC250M-24/BB}}] with optimizers: [SOLAREDGE {POWERBOX 250W OP250-LV-MC4SM-2NA}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75162	16041-10000-40687	2003 S OAK ST 1-29	90007	1	124-5A203 156	5124015906	PF-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Apartment			11/17/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	05/03/2018 12:00:00 AM	ADDRESS	34.03534	-118.27906	Installation of fire alarm system in new 3 story apartment building.  Total system size = 122 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75163	12041-10002-19312	13190 N BROMONT AVE	91342	7	225B153   419	2509003031	R3-1, [Q]C2-1VL	North Valley	Sylmar	Sylmar		1064.07	Electrical	Electrical	Apartment			01/07/2014 12:00:00 AM			PC Approved	01/27/2014 12:00:00 AM	ADDRESS	34.31012	-118.43675	Revisions to approved set.  Addition of aluminum conductor feeder schedule to sheet E-2.0.  Originally plan checked by MZ.  expedited  submital 2(((PLAN CHECK POWER AND ENERGY FOR NEW 3 STORY 49 UNITS APARTMENT OVER 1 STORY TYPE  BASEMENT GARAGE BUILDING.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75164	17041-10000-24535	2945 S WESTERN AVE	90018	10	120B193   342	5053005020	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2220.01	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/24/2017 12:00:00 AM	ADDRESS	34.02767	-118.30916	Plan check for Title 24 only in existing space, remove Indoor and outdoor HID fixtures and replace wiht new LED fixtures, Total area: 8005 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75165	19041-10000-28427	13570 W FOOTHILL BLVD bldg-1	91342	7	222B157   200	2513006900	RD1.5-1XL	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			07/24/2019 12:00:00 AM			PC Approved	08/19/2019 12:00:00 AM	ADDRESS	34.30638	-118.42945	Plan check only. DELTA 3 CHANGES TO AN APPROVED SET. CHANGES TO FIXTURES SCHEDULE, WATTAGE AND TYPES. CHANGES ALSO INCLUDE DECREASING THE HORSE POWER OF THE ELEVATOR, UPDATES TO PHOTOMETRICS, LOAD CALCULATIONS AND T-24. Permit pulled under 18041-20000-39767 & 18041-20000-39770Original scope:New 3-story 21-affordable units apartment.  Scope of this permit is building 1 out of 2 apartment buildings on site.  1600A, 208Y/120V 3ph-4w service (located on Building 1) supplying both buildings 1 and 2 (single feeder).Building permit under 18010-10000-03808.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75166	19041-20000-41430	888 S WAYS ST	90731	15	015B205     7	7440029917	[Q]M3-1	Harbor	Port of Los Angeles			9800.31	Electrical	Electrical	Commercial			10/11/2019 12:00:00 AM			PC Info Complete	02/07/2020 12:00:00 AM	ADDRESS	33.73789	-118.26549	PROVIDE NEW 5000 A 480/277V 3 PHASE SERVICE FOR EXISTING DISTRIBUTION. RECONNECT EXISTING EQUIPMENTS TO NEW MAIN SERVICE SWITCHBOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75167	19041-10000-43677	2255 S SAWTELLE BLVD	90064	11	123B153  1178	4260019013	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2677.00	Electrical	Electrical	Commercial			12/02/2019 12:00:00 AM			PC Info Complete	05/28/2020 12:00:00 AM	ADDRESS	34.03718	-118.44062	PLAN CHECK FOR A NEW 5000A SERVICE (277/480 3P,4W) THAT FEEDS A 5000A SWITCHBOARD WHICH SUBFEEDS VERIOUS ASSOCITED DITRIBUTION EQUIPMENT AND TRANSFORMERS, THE SWITCHBOARD ALSO FEEDS A FIRE PUMP. NOTE THERE IS ALSO A 400KW EMERGENCY GENERATOR WHICH FEEDS ALL ASSOCIATED EMERGENCY LOADS AND THREE ELEVATORS. TOTAL AFFECTED AREA IS 220,602 SQFT, THIS IS A CORE AND SHELL PROJECT ONLY. PER BUILDING((NEW 8 STORY OFFICE AND PARKED GARAGE APPROX 135,000 SQ FT AND CONTAIN 464 PARKING SPACES  PLANNING CASE  DIR 2018-7625 SPR  AND EVN 2018-762619010-10000-04709))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75168	17041-20000-36937	13768 W FOOTHILL BLVD	91342	7	222B153    42	2509019003	C2-1VL-CPIO	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	03/09/2018 12:00:00 AM	ADDRESS	34.30937	-118.43317	Change of use from laundromat to restaurant - plan check for energy.  Building permit filed under 17016-20000-30332	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75169	11041-10000-18225	5005 N EDENHURST AVE	90039	13	162B201    20	5593012032	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/26/2011 12:00:00 AM			PC Approved	08/26/2011 12:00:00 AM	ADDRESS	34.142	-118.2736	T-24 lighting plan check for remodeled space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75170	17041-10000-12450	660 S FIGUEROA ST #1200	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	06/16/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	Title 24 plan check.  T.I. to partiel floor of existing commercial office highrise building.  New lighting and receptacles.  Total area = 2,461 sq. ft.     Building permit #17016-10000-01605	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75171	10041-20000-18631	21300 W VICTORY BLVD #500	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			09/20/2010 12:00:00 AM	09/24/2010 12:00:00 AM		Permit Finaled	12/17/2010 12:00:00 AM	ADDRESS	34.18813	-118.59618	Plan check T-24 energy (general/emergency) lighting for office TI #500	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75172	16041-10000-27070	535 N FAIRFAX AVE	90036	5	141B177  1012	5527020004	C4-1VL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			08/01/2016 12:00:00 AM	08/15/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.08104	-118.36162	PLAN CHECK FOR T-24 ONLY.  TENANT IMPROVEMENT TO (E) RETAIL SPACE. INSTAL NEW LIGHTS AND RECEPTACLES. NEWLY CONNECTED LOAD < 400A.  TOTAL AFFECTED AREA: 2,369 SQ.FT((B# 16016-10000-16602))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75173	13041-10000-24710	3320 S KERCKHOFF AVE	90731	15	006B197   302	7467004044	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Closed	08/31/2015 12:00:00 AM	ADDRESS	33.71382	-118.28961	PV1.  Instal 4.655 kW DC roof-mounted solar array of 19 modules, interconnect with main service panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75174	09041-10001-15382	8050 W 3RD ST	90048	5	138B177   753	5511028012	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			03/03/2010 12:00:00 AM			Corrections Issued	03/03/2010 12:00:00 AM	ADDRESS	34.07194	-118.36552	EPC for changes in lighting from previously approved plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75175	17041-10000-06084	3111 S LA CIENEGA BLVD	90016	10	123B173  1531	4205035014	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			02/24/2017 12:00:00 AM			PC Approved	02/24/2017 12:00:00 AM	ADDRESS	34.02983	-118.37395	T-24, PC For energy only. TI to an existing commercial office building. Scope includes new lights and receptacles. Total affected area is 5985 Sq. Ft. b#16016-10000-25334Note: Permit is paid under PCIS#17041-90000-02221	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75176	19041-10000-40191	12941 W HESBY ST	91423	4	171B161   864	2358028006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/29/2019 12:00:00 AM		Permit Finaled	11/30/2019 12:00:00 AM	ADDRESS	34.16245	-118.41561	[EPLAN] PLAN CHECK FOR 7.6KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 21 MODULES USING P400 OPTIMIZERS, AND ESS(TESLA POWERWALL) CONNETED TO EXISTING 200A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75177	19041-10000-50287	18133 W VENTURA BLVD Unit #C	91356	3	171B125   271	2160017015	(Q)C2-1VLD	South Valley	Encino - Tarzana	Tarzana		1395.02	Electrical	Electrical	Commercial			12/06/2019 12:00:00 AM	12/06/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.16603	-118.52861	"TI IN AN EXISTING OFFICE BULDING (NON-MEDICAL) IN UNIT ""C"". INSTALLING NEW LIGHTS. T-24 ENERGY ONLY. AFFECTED AREA: 2021 SFT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75178	15041-20000-43517	8717 N DARBY AVE	91325	12	195B125   809	2769025011	M1-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/24/2015 12:00:00 AM	02/02/2017 12:00:00 AM		Permit Finaled	03/22/2018 12:00:00 AM	ADDRESS	34.2292	-118.53371	Plan check for power and energy. Project site is an existing commercial building. Project scope is a tenant improvement. Work includes a 600-amp service, (9) panels, associated loads, and (3) transformers. Total indoor lighting area = 4,407 sq. ft.Note: Building permit has been pulled under 15016-20000-19759 (Occupant load is 50)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75179	13041-20000-03168	400 S HOPE ST GROUND FLR	90071	14	130-5A211  38	5151017019	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM	04/11/2013 12:00:00 AM		Permit Finaled	02/03/2014 12:00:00 AM	ADDRESS	34.05199	-118.25366	Install new distribution boards, elevator, lighting, and receptacles associatated with an ALTERATION OF GROUND FLOOR LOBBY & ADDED CONSTRUCTION OF RESTROOMS, SERVICE ELEVATOR & LOBBY FINISHES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75180	17041-20000-26310	2429 N LYRIC AVE	90027	4	150B201  1115	5433009005	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.10515	-118.27605	27 KWY ENERGY STORAGE + PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 6.93 KWNote: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75181	18041-20000-41364	1032 N CORONADO ST	90026	13	141A205   354	5402020003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1957.10	Electrical	Electrical	Apartment			10/29/2018 12:00:00 AM	05/12/2021 12:00:00 AM		Permit Finaled	12/13/2023 12:00:00 AM	ADDRESS	34.07897	-118.26918	1200A 240/120V 3ph-4w service, distribution, power, and lighting for new multifamily residential construction.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75182	15041-20000-19378	3456 S MOTOR AVE	90034	5	120B161   364	4314016024	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.07	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	08/11/2015 12:00:00 AM		Permit Expired	09/05/2017 12:00:00 AM	ADDRESS	34.02698	-118.40853	Plan check for power and Title 24.  Total area = 935 sq. ft.  T.I. to commercial restaurant first time tenant.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75183	11041-20000-09507	20720 W MARILLA ST	91311	12	201B109   178	2748004046	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			05/10/2011 12:00:00 AM	12/23/2011 12:00:00 AM		Permit Finaled	11/08/2012 12:00:00 AM	ADDRESS	34.24798	-118.58532	T.I. to existing building.  Install panels and branch circuits with new load exceeds 400 amps.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75184	14041-10000-12834	725 S FIGUEROA ST 26th floor	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	08/07/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.04886	-118.26071	Title 24 plan check for restroom remodel in highrise commercial space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75185	19041-10001-00775	10514 W DUNLEER DR	90064	5	123B161   360	4318037028	R1V2	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM			PC Approved	02/27/2019 12:00:00 AM	ADDRESS	34.03512	-118.41433	Expedite per applicant request(((plan check for a 15.2 KW AC/ 18.6KW DC roofmounted system with (60) modules (2) inverter , and (60) optimizers interconnecting through the main service.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75186	17041-30000-19017	6330 W SAN VICENTE BLVD STE 200	90048	5	132B173   120	5088018023	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/06/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.06116	-118.36804	Plan check for Title 24 only in existing space offices T.I. Total area: 296 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75187	13041-10000-00727	719 S BROADWAY	90014	14	127-5A209  53	5144014037	[Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.00	Electrical	Electrical	Commercial			01/10/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	03/05/2013 12:00:00 AM	ADDRESS	34.04483	-118.25393	installation of a fire alarm system in the basement and first level of a department store. total of 159 devices and 1 panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75188	11041-10000-21270	22811 W GERSHWIN DR	91364	3	168B097   413	2074027030	RE15-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			10/05/2011 12:00:00 AM			Corrections Issued	11/16/2011 12:00:00 AM	ADDRESS	34.15675	-118.62477	PV system for SFD 3 strings with micro inverter. RFM for Enphase Model M215 was submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75189	14041-10000-25708	9763 W SUFFOLK DR	90210	5	159B157   245	4385001026	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			09/29/2014 12:00:00 AM			Reviewed by Supervisor	10/07/2014 12:00:00 AM	ADDRESS	34.12924	-118.42896	PV1, INSTALL 11.73 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(46) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERS: SOLAREDGE SE5000A-US-ZB-U & SE6000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75190	15041-20000-18712	6320 N TOPANGA CANYON BLVD G-1633	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/16/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	10/03/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	Plan check for power and Title-24 (energy).  Total area = 1,586 sq. ft.  T.I. to commercial first time tenant.  New lighting and recepticles.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75191	14041-20000-05324	18151 W NAPA ST	91325	12	192B125    28	2786002027	M1-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Commercial			02/26/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Expired	12/23/2016 12:00:00 AM	ADDRESS	34.22656	-118.52911	Install indoor lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75192	16041-10004-05433	8440 N BALBOA BLVD NORTH-BLDG	91325	12	192B133   153	2689019012	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/02/2018 12:00:00 AM			PC Approved	04/19/2018 12:00:00 AM	PIN	34.22359223	-118.50180382	*************    SEE APPLICATION COMMENTS  ********************PC FOR CHANGES TO APPROVED SET PER INSPECTION UNDER DELTA 9. (NORTH BUILDING)SCOPE INCLUDES REDUCTION IN SCOPE TO REFLECT FIELD CONDITIONS AND INCLUDE: LIGHTING (INDOOR AND OUTDOOR), EQUIPMENT, LOADING AND T-24 REVISIONS. THIS IS PLAN CHECK ONLY.  one of two new buildings with retail tenant spaces-SHELL/CORE ONLYThis North Building (16010-10000--00456) plans will be reviewed under this application.A separate application will be required for plan review of the plans for the West Building (16010-10000-004550)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75193	18041-10000-32294	822 N ALVARADO ST	90026	13	139-5A207 313	5404007006	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1957.20	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.07522	-118.26473	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75194	15041-20001-39991	8724 N OAK PARK AVE	91325	12	195B133   399	2690010010	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2015 12:00:00 AM			PC Approved	12/24/2015 12:00:00 AM	ADDRESS	34.22921	-118.50556	Expedited per customer request.PV1. Install roof mounted PV system sized 11.4 kW. Interconnectd with main service panel.(41) SunEdison 325W Modules(41) SolarEdge P320 Power Optimizers(1) Solar Edge SE11400A Inverter	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75195	14041-10000-16699	15729 W VOSE ST	91406	6	183B141   292	2224005024	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM	08/08/2014 12:00:00 AM		Permit Finaled	09/17/2014 12:00:00 AM	ADDRESS	34.19855	-118.47625	Roof mounted PV installation on existing residential property.  Total system size = 13.4 kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75196	15041-10000-38807	7291 N FIGUEROA ST	90041	14	160-5A229  64	5690029036	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1815.00	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	12/17/2015 12:00:00 AM	ADDRESS	34.13538	-118.18902	AT A N AUTO REPAIR SHOP, REPLACING HID LUMINAIRES WITH LED LUMINAIRES WITH DIMMER AND OCCP SENSORPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75197	13041-10000-27660	20731 W MARILLA ST	91311	12	201B109   153	2748004041	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/04/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.24819	-118.58529	PV2.  Install 88.944 kW DC rooftop-mount solar array, interconnect with existing distribution system.  Transformed commercial inverter: Solectria PVI-85KW-PE .  272 modules: SunPower -SPR-327E-20 WHT-Dthe $0 permit fee is due to the 2012 Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75198	13041-10000-21842	1715-1719 W SUNSET BLVD	90026	13	139-5A209  84	5419030009	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1974.20	Electrical	Electrical	Commercial			08/13/2013 12:00:00 AM			PC Approved	08/15/2013 12:00:00 AM	ADDRESS	34.07761	-118.25881	T24 for retail TI.  Front of space to be jewelry store, back of space to be work area for restaurant.  Plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75199	16041-30000-17322	4122 S BUCKINGHAM ROAD 1-4	90008	10	114B181    86	5032015002	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Apartment			05/17/2016 12:00:00 AM			PC Approved	07/07/2016 12:00:00 AM	ADDRESS	34.01137	-118.34269	Plan check for Title 24 only. Project site is an existing apartment building. Project scope is the addition of a new accessory laundry room. Total lighting area = 160 sq. ft.Note: Building application has been generated under 16010-30000-01106	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75200	15041-10000-04277	9725 N VARIEL AVE	91311	12	201B105   160	2746004029	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/19/2015 12:00:00 AM	ADDRESS	34.24699	-118.59306	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL  AREA 8064 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75201	14041-10000-29100	586 S MATEO ST	90013	14	126A217   105	5164007001	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/21/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	03/18/2015 12:00:00 AM	ADDRESS	34.03893	-118.23265	T24 plan check at counter. Total area = 3315 sq. ft. Retail low rise building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75202	17041-10000-32898	450 S WESTERN AVE SUITE 212	90020	10	135B193   626	5503014020	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.04	Electrical	Electrical	Commercial			09/14/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Issued	09/27/2017 12:00:00 AM	ADDRESS	34.06562	-118.30887	PC FOR T24 ENERGY ONLY. RETAIL TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75203	14041-20000-16316	14072 N CARLTON LN	91342	7	231B153   145	2582041***	(T)(Q)RD6-1, A1-1, QRD6-1, [Q]PF-1VL	North Valley	Sylmar	Sylmar	YES	1060.10	Electrical	Electrical	1 or 2 Family Dwelling			06/18/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	PIN	34.32835381	-118.44001274	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECT WITH MAIN PANEL.(17) MODULES SUNMODULE SW250 WITH POWER OPTIMIZERS(1) TRANSFORMERLESS INVERTER SOLAR EDGE SE3800A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75204	17041-20001-16993	9408-9410 N OWENSMOUTH AVE	91311	12	198B105    66	2746014044	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Issued	10/10/2017 12:00:00 AM	PIN	34.2410613	-118.60115579	[[10/10/17 CHANGES TO APPROVED SET. INSTALLATION OF NEW STANDBY GENERATOR AND REFRIDGERATOR RECEPTACLES]]]]PC for power and energy for TI for electronic manufacturing facility in second floor of building. PC includes check for new 3000 A 277/480 service, new electronic manufacturing equipment, spray booth, outdoor compressor and power supply units for equipment. Total affected area is 15369 sqft.Bulding # 17016 20000 05741	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75205	18041-10002-17068	1420 N LAUREL WAY	90210	5	147B161   224	4355015051	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/09/2018 12:00:00 AM			PC Approved	05/15/2018 12:00:00 AM	ADDRESS	34.09776	-118.41779	NEW 16.8KW ROOF MOUNTER PV SYSTEM WITH 46 PV MODULES ON A SINGLE FAMLY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75206	17041-10000-17111	4216 S BUDLONG AVE	90037	9	114B197   852	5020022006	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.00672	-118.29575	PC for rooftop solar for new SE5000A 5KW system with central inverter and 19 optimizer. PC for 19 CS6K-275 solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75207	14041-10000-32569	3323 S CLUB DR	90064	5	123B165   761	4316025013	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			Reviewed by Supervisor	12/11/2014 12:00:00 AM	ADDRESS	34.03234	-118.40276	PV1, INSTALL  10.71 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(2) INVERTERS: SOLAREDGE SE5000A-US-ZB-U  (42) MODULES: KYOCERA KD255GX-LFB3	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75208	18041-20000-49104	10980 W VERANO ROAD pv1	90077	5	144B145    32	4377023001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	07/05/2019 12:00:00 AM	ADDRESS	34.09486	-118.46249	Install roof mounted pv system sized 18.2KW AC interconnected with msp.(2) tesla batteries 5KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75209	10041-10000-21476	4651 S ALLA ROAD	90292	11	105B157   446	4212007900	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			10/28/2010 12:00:00 AM	12/02/2010 12:00:00 AM		Permit Finaled	09/10/2013 12:00:00 AM	PIN	33.98402746	-118.43153196	New restroom. Plan Check is for T-24 Energy Calcs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75210	11041-10000-10626	1119 S WESTCHESTER PL	90019	10	129B189   585	5081019012	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	Apartment			05/24/2011 12:00:00 AM	06/16/2011 12:00:00 AM		Permit Finaled	09/16/2011 12:00:00 AM	ADDRESS	34.05009	-118.31784	TI TO AN EXISTING CONVENT, IN SHARED KITCHEN AND RESTROOM AREAS.  T-24, OTC PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75211	18041-10000-23554	355 S GRAND AVE 1900- 2010	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/25/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	PC FOR POWER AND ENERGY FOR OFFICE TI ON THE 19TH AND 20TH FLOOR. TOTAL CONNECTED LOAD >400ASCOPE INCLUDES NEW CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 23439  SQ.FTB# 17016-20000-36395	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75212	15041-20001-08533	6344 N TOPANGA CANYON BLVD #1050	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM			PC Approved	08/25/2015 12:00:00 AM	ADDRESS	34.18628	-118.60544	"08/14/2015 Changes to an approved set of plans. Changes include the addition of an emergency shunt relay for the emergency lighting. *****Previous Work Description*****Plan check for power and energy for first time tenant (new restaurant = Tender Greens). Total area: 3177 sq ft. Part of Building A of ""Westfield Topanga"" mall."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75213	15041-10001-14822	8468 W MELROSE PL	90069	5	141B173   514	5528017026	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.0834	-118.37563	Change to approved set by modifying the lighting plan and the calculation on T-24 forms. (((TI-24 TO AN (E) COMMERCIAL BUILDING. NEW LIGHTING AND NEW RECEPTACLES.  PC FOR ENERGY TOTAL SQ FT. 2752)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75214	16041-10000-42314	3200 S FIGUEROA ST	90007	9	120A203   134	5123020016	C2-1L	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			12/02/2016 12:00:00 AM	12/02/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.02321	-118.27892	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDE REPLACING EXTERIOR HID FIXTURES WITH NEW LED FIXTURES FOR AN EXISTING BUILDING. TOTAL AFFECTED AREA IS 111650 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75215	16041-10001-18570	6201 W HOLLYWOOD BLVD #104	90028	13	148-5A189 350	5546032***	[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Closed	09/05/2018 12:00:00 AM	ADDRESS	34.1018	-118.32461	Plan check for Electrical System only (T-24 was done under the master E#). This is per inspector's request (1st time tenant).NOTE: Permit includes both transformers which were not included on the master permit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75216	14041-20000-10211	4700 S INGLEWOOD BLVD #101, #102	90230	11	108B161   213	4218008012	(Q)C2-1, C2-1, P-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	05/04/2015 12:00:00 AM	ADDRESS	33.99346	-118.41537	T.I. to medical office.  Install subpanels, branch circuits, optional standby system, and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75217	14041-10009-15237	930 W WILSHIRE BLVD	90017	14	130-5A209 219	5144008021	C2-4D-SN	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/02/2017 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.0504	-118.26023	02/02/2017 Changes to an approved set of plan. Changes include additional 5 panels and 2 transformer, remove lighting and add new lighting, Title  24 recalculation did not provided. Changes has been clouded as delta 9	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75218	14041-20000-25872	11513 N VALJEAN AVE	91344	12	213B137   548	2605022013	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Permit Finaled	12/29/2014 12:00:00 AM	ADDRESS	34.27982	-118.48703	CENTRAL STRING INVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75219	16041-10001-22481	777 N VINE ST	90038	13	141B185   269	5533031024	C2-1D	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.0851	-118.32678	Plan check only. PC for title 24. Checking for power controlled receptacles only. on each of the units. No lighting check. (((UPGRADE (REPLACE EXISTING) LIGHT FIXTURES W/ NEW & ADD ADDITIONAL LIGHT FIXTURES.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75220	14041-10002-13075	19401 W PARTHENIA ST	91324	12	195B117   188	2783027044	[Q]C2-1L	North Valley	Chatsworth - Porter Ranch	Northridge South		1134.01	Electrical	Electrical	Commercial			11/06/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Finaled	08/02/2016 12:00:00 AM	ADDRESS	34.22847	-118.55614	Revisions to permitted plans for new 5-stories parking structure under construction.New circcuits, panelboards, and some feeders changed from CU to AL. (((((Full Plan check for new 5 stories parking structure,	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75221	18041-20000-20361	9656 N WHITE OAK AVE	91325	12	201B129   269	2755007014	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	10/01/2018 12:00:00 AM	ADDRESS	34.24651	-118.51986	Plan check for addition of PV roof mounted system to exsiting. Addition PV system size: 10KWac with 28 modules and 1 inverter(10kW)Note Existing PV system size: 7.0kW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75222	17041-10000-05266	8464 W MELROSE PL	90069	5	141B173   513	5528017027	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			02/17/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.08341	-118.3755	PC FOR ENERGY ONLY IN COMMERCIAL BUILDING. TOTAL AFFECTED AREA 3513 SQ.FTSCOPE INCLUDES LIGHTING AND RECEPTACLES. BUILDING PERMIT UNDER 16016-30000-23174	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75223	19041-20001-39198	22322 W COLLINS ST	91367	3	174B101   187	2146010014	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			09/27/2019 12:00:00 AM			PC Approved	11/15/2019 12:00:00 AM	PIN	34.17332386	-118.61271322	Expedited plan check fee.PV3.  Install 24.75 kW DC / 22.52 kW AC-CEC roof mounted grid tied PV system.  (75) modules with microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75224	13041-20000-08316	1030 N ECHO PARK AVE PV-1	90026	1	139-5A209 635	5404019007	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2013 12:00:00 AM	05/15/2013 12:00:00 AM		Permit Finaled	05/24/2013 12:00:00 AM	ADDRESS	34.07474	-118.25842	"Pv-1. Plan check for single family. One 7kW inverter, positively grounded. Please include 200A service upgrade for permit under ""inspection""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75225	15041-20001-31735	7035 N HAZELTINE AVE	91405	6	183B153   470	2217015005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			09/24/2015 12:00:00 AM			PC Approved	11/12/2015 12:00:00 AM	ADDRESS	34.19862	-118.44016	Expedite fees only.      Installation of new roof mounted solar PV array.  Total system size = 3 kWac.  Central inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75226	13041-10000-07438	446-450 S MAIN ST	90013	14	129A211   140	5148009012	[Q]C4-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			03/22/2013 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	10/22/2014 12:00:00 AM	ADDRESS	34.0471	-118.24791	Full plan check power and energy for renovation of theater. New service size 800A. Total new load 740A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75227	19041-10000-47616	1130 W MARTIN LUTHER KING, JR BLVD	90037	9	114B197   246	5020017007	C2-1-CPIO	South Los Angeles	South Los Angeles	Voices		2316.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	02/24/2020 12:00:00 AM		Permit Finaled	07/28/2023 12:00:00 AM	ADDRESS	34.01067	-118.2952	NEW PLAN CHECK FOR A NEW 1200A 208/120 3PH 4W SERVING 1200A DISTRIBUTION AND 800A MAIN SWITCH BOARD. SCOPE INCLUDES A 225A HOUSE PANEL AND 29 100A UNIT PANELS. SCOPE INCLUDES A NEW 20HP ELEVATOR. TOTAL AFFECTED AREA IS 4822 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75228	10041-20000-19571	434 S SAN PEDRO ST	90013	9	127-5A213 135	5147007020	PF-2D	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			10/01/2010 12:00:00 AM	10/29/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	34.04473	-118.24336	Plan check T-24 Energy (general/emergency) lighting for TI of dining/retail space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75229	14041-20000-30565	9000 N WOODMAN AVE	91331	6	195B153   244	2642031022	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			11/04/2014 12:00:00 AM	02/04/2015 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.2333	-118.43868	REOPENING AN EXISTING RESTAURANT SINGLE STORY.  PLAN CHECK FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75230	14041-10000-34719	8556 S EMERSON AVE UNIT 6	90045	11	096B165   524	4108018021	[Q]C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	01/21/2015 12:00:00 AM	ADDRESS	33.9601	-118.40419	(Building 6 of 12) Plan check for power and energy. Project scope is 12 new towne holmes. This is Building 6 of 12 buildings total. Building 6 has 150 amp service and is adjecent to (1) of (2) 600 amp main services.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75231	15041-10000-36826	8053 W BEVERLY BLVD	90048	5	138B177   392	5514007045	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.07625	-118.36499	ALTERATIONS  (BLDG PERMIT  PRIOR TO 2014 ) IN GYMNASIUM-FITNESS ROOM ON 3RD FL; LOCKER ROOM ON MEZZANINE;  GYMN ON 2ND FLPLAN CHK ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75232	17041-10001-07570	443 N FAIRFAX AVE	90036	5	141B177  1285	5527031018	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM			Corrections Issued	09/21/2017 12:00:00 AM	ADDRESS	34.0794	-118.36161	withdrawn per applicant requestSupplemental for lost set of plans.**T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2250 SQ. FT. B#17016-10000-03148	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75233	17041-10001-46381	1269 N WILTON PL	90038	13	144B189    68	5536001011	C2-2, P-2	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM			Corrections Issued	01/28/2019 12:00:00 AM	ADDRESS	34.09434	-118.31381	PC for T24 only for change of use to Ice Cream shop. Installing new lights, receptacles, and equipment. Total area is 708sqft. Fees are covered under master permit 17041-10000-46381. B# 16016-10000-10292.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75234	15041-10000-41825	807 N HUDSON AVE	90038	4	141B185   235	5533025056	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/11/2015 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	ADDRESS	34.08556	-118.33232	Installation of a new FA system to a 34 units 4-story apartment. (1) FA panel, (2) Control panel, (1) Communication panel. (197) FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75235	12041-10002-15380	4401 S CRENSHAW BLVD Basement	90043	8	111B185   131	5013013013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2345.02	Electrical	Electrical	Commercial			06/04/2013 12:00:00 AM			PC Approved	06/20/2013 12:00:00 AM	PIN	34.00326739	-118.33207301	Plan check only for revision to approved plans.  Modifications to lighting installation, T24 Energy calculation, circuit locations, and emergency lighting wiring.  Permit under #12041-10000-15380.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75236	16041-20000-26471	3210 W PERLITA AVE	90039	13	153B209   836	5436018003	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.02	Electrical	Electrical	1 or 2 Family Dwelling			07/27/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	08/06/2016 12:00:00 AM	ADDRESS	34.11365	-118.25248	Plan check for a PV1 roof-mounted PV system. System size is 4.2 kWac and consists of (15) modules, (15) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75237	19041-10000-46601	18812 W COHASSET ST	91335	3	186B121   453	2118003018	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM			PC Approved	11/13/2019 12:00:00 AM	ADDRESS	34.2064	-118.54311	PLAN CHECK ONLY FOR A SOLAR ROOFTOP SYSTEM, SCOPE OF WORK IS 18 MODULES (SUNPOWER SPR-327NE-WHT-D)  LEADING TO A CENTRAL INVERTER (SUNNY BOY SB5000TL). NOTE ALL PERMIT FEES ARE PAID UNDER 16041-90000-33002	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75238	13041-10000-34957	380 WORLD WAY Space T64	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Approved	12/16/2013 12:00:00 AM	ADDRESS	33.94373	-118.40888	PROPOSED 541 SQFT  TENENAT IMPROVEMENT  FOOD & BEVERAGE CONCESSION SPACE ( Drink LA). T72  level 5	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75239	10041-10000-00146	547 S SEATON ST	90013	14	126A215   150	5163027010	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			01/05/2010 12:00:00 AM			Reviewed by Supervisor	02/08/2010 12:00:00 AM	ADDRESS	34.04008	-118.2373	Plan check power for new service upgrade to 600A and new equipment installed. In methane zone	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75240	12041-10000-15288	139 N WESTERN AVE	90004	4	138B193   868	5517003002	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2115.00	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	12/17/2012 12:00:00 AM	ADDRESS	34.0741	-118.3095	FIRST TIME TENANT IN NEW COMMERCIAL SPACE-USING 2 TENANT SPACES FOR A NEW RESTAURANT FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75241	15041-10001-20233	4975 W SUNSET BLVD	90027	13	147B197   708	5543006024	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			10/14/2016 12:00:00 AM			PC Approved	10/14/2016 12:00:00 AM	ADDRESS	34.09829	-118.29805	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDES: ADDITION OF EXIT SIGNS AND RELOCATING SOME OTHER LIGHTS. T24 PLAN CHECK ONLY.<<<PLAN CHECK FOR POWER AND ENERGY FOR CHANGE OF USE CHURCH TO OFFICE. NEW 1000AMP SERVICE. ALL ELECTRICAL EQUIPMENT ARE NEW.**3/8/16: Fire Alarm Variance is filed>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75242	11041-10002-11468	451 S HEWITT ST	90013	9	127-5A215 370	5163022019	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			11/29/2011 12:00:00 AM	02/07/2012 12:00:00 AM		Permit Finaled	05/08/2012 12:00:00 AM	ADDRESS	34.0421	-118.23525	Modification to previously approved plans, change to use series rated breakers and additional circuits.   NO change to lighting on this plan <<<<<CHANGE OF USE FROM AN OFFICE BUILDING TO A COFFEE ROASTING PLANT.  PLAN CHECK FOR ENERGY AND POWER.>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75243	19041-10000-38292	5670 W WILSHIRE BLVD Ste. 2100	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			09/24/2019 12:00:00 AM			PC Approved	09/24/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	Energy plan check for an office T.I located on the 21st floor of a high rise building. Scope includes new lighting and equipment with a total lighting area of 5,160-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75244	18041-10000-46410	12520 W MULHOLLAND DR	90210	4	156B161    23	4387002900	[Q]PF-1XL	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	Yes	2611.01	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.12711	-118.40605	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75245	14041-20001-25879	13435 W DESMOND ST	91331	7	213B157   667	2523017017	R1-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			PC Approved	10/03/2014 12:00:00 AM	ADDRESS	34.27756	-118.42545	Modification to approved set.  Additional subpanel for relocated existing loads connected to MSP.  (((PV1 SFD. TOTAL SYSTEM SIZE 3.8KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZES.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75246	14041-20000-17267	6621 N FALLBROOK AVE 1st  FLOOR	91307	12	180B097   429	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.19037	-118.62371	T.I. to World Market.  Install fire pump, panels, branch circuits, and lighting.   Plan check for power and energy.Note: Variance to separate fire alarm submitted on 11/13/14	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75247	14041-20000-00633	12943 W AZTEC ST	91342	7	228B161   260	2511035019	RS-1	North Valley		Sylmar		1061.11	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.32276	-118.41532	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING ENPHASE MICROINVERTER M215. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75248	18041-20000-05913	8511 N FALLBROOK AVE 2nd Floor	91304	12	192B097   585	2005022004	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	02/16/2018 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	34.22466	-118.62773	Plan check for Title 24 only. Project site is the 2nd floor common areas of an existing commercial office building. Project scope is a tenant improvement. Total lighting area = 3,108 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75249	14041-10000-11297	1537 N NORFOLK ST 2F	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.06138	-118.20223	Renovate power & lighting in dermatology suite.  Plan check for  lighting & power. BLDG#14016-10-06304.Plan check: 14041-10-11295 covers other half of 2nd floor.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75250	16041-20000-14660	16633-16642 W ARMINTA ST	91406	6	189B137    42	2205009037	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM	04/12/2017 12:00:00 AM		Permit Finaled	10/13/2017 12:00:00 AM	ADDRESS	34.21474	-118.4959	Install a roof-mounted solar array on a commercial building. Interconnect directly to LADWP = FEED-IN-TARIFF SYSTEM. System size: 60kW [(3) 20kW inverters]. Ungrounded system.(218) 260W pv modules.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75251	13041-10000-31863	1508 N MERCURY DR PED	90042	14	157-5A229 629		R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1832.21	Electrical	Electrical	Commercial			11/14/2013 12:00:00 AM	01/27/2014 12:00:00 AM		Permit Expired	02/19/2016 12:00:00 AM	ADDRESS	34.12712	-118.18873	PLANCHECK ONLY FOR T24 ENERGY ONLY. OUTDOOR LAMP FOR MERCURY STREET. PEDESTAL. PRIVATE STREET OWNED BY HOA. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75252	13041-20000-02823	1702 N SUNSET PLAZA DR	90069	5	148-5A173 246	5558016025	R1-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00, 1943.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	34.10163	-118.37942	Photovoltaic system on roof of a single family dwelling using Enphase inverters.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75253	18041-10000-30320	1851 N GAFFEY ST	90731	15	024B197    78	7442022021	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	Commercial			08/10/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	33.7617	-118.29322	NEW MEDICAL (chiropractor ) OFFICE. EXISTING SERVICE & PANELS, NEW CIRCUITS. PLAN CHECK FOR POWER & ENERGY. TOTAL AFFECTED AREA IS 5350 SQ. FT. BLDG PERMIT: 17016-40000-37460NOTE: PORTION OF THE  PERMIT FEE  IS PAID UNDER PCIS#18041-40000-14852	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75254	15041-20003-13990	6121 W SUNSET BLVD	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.09818	-118.32309	[[10/6/15  CHANGES TO APPROVED SET OF PLANS. DELTA 3 CHANGES ONLY. CHANGES TO SCREENING ROOM AND BACK OF HOUSE TO ADD BUG EYES AND PHOTOMETRICS]]]]][20002-9/15/15   PLAN CHECK FOR CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE PHOTOMETRIC FLOOR PLAN FOR EGRESS. REVISION OF PANEL SCHEDULES AND FLOOR PLANS DUE TO KITCHEN REVISIONS. RESTAMP NEW SET. PLAN CHECK ONLY.]][MASTER APP -FULL TI TO ALL 6 FLOORS. CORE AND SHELL UNDER SEPARATE PERMIT. THIS TI IS FOR THE NEUEHOUSE.THIS IS A NEW SUBMITTAL WITH NEW PERMIT. ALL PREVIOUS APPLICATIONS VOID. THIS PLAN CHECK AND PERMIT TO COMPLY WITH 2008 VERSION OF THE CALIFORNIA ENERGY CODE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75255	11041-20000-06690	11100 W MAGNOLIA BLVD	91601	4	171B173   614	2353005003	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20, 1254.00	Electrical	Electrical	Commercial			04/05/2011 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Finaled	08/03/2011 12:00:00 AM	ADDRESS	34.16478	-118.37255	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75256	15041-10001-27827	3758 N LANKERSHIM BLVD	90068	4	162B177   574	2380001044	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	34.13639	-118.36438	PV 1, single family home. (1) inverter: 6 KW, (20) modules. Submittal per applicants request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75257	14041-10000-07434	4248 S LINCOLN BLVD	90292	11	105B153    68	4230001018	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			03/20/2014 12:00:00 AM			PC Approved	03/20/2014 12:00:00 AM	ADDRESS	33.98613	-118.44355	TITLE 24, ON A ONE STORY RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75258	17041-10000-40506	3411 W LACLEDE AVE	90039	13	153B209   171	5436006029	R1-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2017 12:00:00 AM	11/08/2017 12:00:00 AM		Permit Finaled	11/15/2017 12:00:00 AM	ADDRESS	34.11818	-118.25563	PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER AND SOLAR OPTIMIZERS. (22) MODULES AND (1)6KW INVERTER.  TOTAL SYSTEM SIZE IS 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75259	15041-10000-17948	5510-5570 S LINCOLN BLVD	90094	11	102B157   355	4211022013	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/10/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Finaled	06/15/2015 12:00:00 AM	ADDRESS	33.97299	-118.43051	front end replacement of existing notifier facp in bldging 5510 and  in bldging 5570 with a new addressable facp.Building 5510 will be the main FACP ;  Bldging 5570 FACP WILL REPORT TO bLDGING 5510	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75260	18041-10000-36420	1309 W SEPULVEDA BLVD	90501	15	045B197   144	7347018094	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			09/24/2018 12:00:00 AM	10/04/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	33.81485	-118.29961	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. COMMERCIAL OFFICES IN APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75261	19041-20000-13821	13353 W PIERCE ST	91331	7	204B157    39	2620012014	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.20	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	05/23/2019 12:00:00 AM	ADDRESS	34.25965	-118.424	PV1.  Install 1.85 kW rated roof mounted grid tied PV system.  (5) modules with replacement of (E) inverter with (N) 5 kW rated string inverter.  Power optimzers being added to (E) array of (19) modules and connected to (N) inverter.  (E) solar PV system on site - total system size new and existing components is 11.812 kW AC-CEC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75262	17041-10000-35557	380-384 W WORLD WAY MSC Temp-Power	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/04/2017 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	PIN	33.94094587	-118.40577128	Plan check for power only for Temp power  Medium Voltage 4160 V for infrastructure for future loads at LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75263	11041-10000-02649	4928 N BALBOA BLVD	91436	5	168B133    77	2259010001	C4-1VL	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			02/10/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	06/08/2011 12:00:00 AM	PIN	34.15988743	-118.50066576	TI IN AN EXISTING RESTUARANT. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75264	14041-10000-27220	1351 N SPAULDING AVE	90046	4	147B177  1301	5551030010	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			Reviewed by Supervisor	10/14/2014 12:00:00 AM	ADDRESS	34.09578	-118.35721	INSTALL 8.925 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(35) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER(S): SOLAREDGE SE3800A-US-ZB-U & SE5000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75265	18041-20000-17763	17969 W MAYERLING ST	91344	12	216B129   477	2601029019		North Valley	GRANADA HILLS - KNOLLWOOD			1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2018 12:00:00 AM	05/14/2018 12:00:00 AM		Permit Finaled	08/03/2018 12:00:00 AM	ADDRESS	34.28825	-118.52437	Plan check for PV roof mounted system, system size: 6.0kW with 21 modules and 1 inverter(6.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75266	17041-10000-13366	769 S GLADYS AVE	90021	14	124-5A213  61	5146029043	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/24/2017 12:00:00 AM	02/13/2018 12:00:00 AM		Permit Finaled	05/07/2018 12:00:00 AM	ADDRESS	34.03681	-118.24553	PC for power for restoration project for existing building. PC for 6 new panels with two services switchboards.Services to be reconnected by DWP after permit is issued. Only shell building with no loading on panels. Final investigation fee to be added to permit fee under CEIS 740868. Builidng #17016-40000-08659	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75267	15041-20001-37597	1017 N LAS PALMAS AVE	90038	4	144B185   896	5532026036	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/27/2016 12:00:00 AM			PC Approved	04/27/2016 12:00:00 AM	ADDRESS	34.08943	-118.33642	Architectural revisions to 1st floor office tenant space; changes to plug types at office workstations in clouded area on plans.  Approval of changes limited to clouded portions of plan only.  (((PLANCHECK FOR POWER AND ENERGY. INTERIOR TI FOR FLOORS 1,2 AND 3.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75268	12041-10000-18167	3450 S WATT WAY	90089	9	120A201    66	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/03/2012 12:00:00 AM			PC Approved	08/03/2012 12:00:00 AM	ADDRESS	34.02275	-118.28604	Lost set of plans. No changes to original plan on 12041-10000-01550.Change of lighting and new circuits for HVAC and receptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  No suite number, per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75269	18041-10000-29155	20925 W OSBORNE ST	91304	3	195B109    28	2779001042	[T][Q]MR1-1VL	North Valley	Chatsworth - Porter Ranch	Canoga Park		1134.21	Electrical	Electrical	Commercial			08/02/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Issued	08/03/2018 12:00:00 AM	ADDRESS	34.23316	-118.58933	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75270	13041-20000-03760	17748 W ALONZO PL PV-1	91316	5	165B129    66	2182026003	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2013 12:00:00 AM	02/26/2013 12:00:00 AM		Permit Finaled	05/03/2013 12:00:00 AM	ADDRESS	34.15232	-118.51952	Plan check for PV system. Ground mount.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75271	15041-20001-04938	10204 N MASON AVE	91311	12	204B109   191	2741005008	(Q)C2-1L	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM			PC Approved	09/08/2015 12:00:00 AM	ADDRESS	34.25583	-118.57964	09-08-2015 Change to approved set of plans. Changes include added dimmer power pack to dim the lighting fixtures.  Changes apply to Delta 4 and Lighting Control Matrix only. {{{{{{PLANCHECK FOR POWER AND ENERGY. VETERINARIAN CLINIC 3594 SQ FT TENANT IMPROVEMENT WITHIN EXISTING SHOPPING CENTER. NEW VETERINARIAN CLNIIC INCLUDES LOBBY, RESTROOMS, EXAM ROOMS, TREATEMENT AREA, XRAY SURGERY AND SUPPORT AREAS. NO OVERNIGHT STAYS PERMITTED}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75272	16041-20000-23878	694 N AMALFI DR	90272	11	126B133   165	4408017009	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2016 12:00:00 AM	08/12/2016 12:00:00 AM		Permit Finaled	01/19/2018 12:00:00 AM	ADDRESS	34.04048	-118.51163	Plan check for PV ground mount system Supply side tap. System size: 25.6kW with 80 AC ModulesNote: Applicant will submit structural support for ground mount to Building Plan Check	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75273	11041-10000-19880	21031 W VENTURA BLVD 101	91367	3	171B105   125	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			09/19/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	PIN	34.16717222	-118.59179488	Dental Office Tenant Improvement. Plan check for Power & Energy. Permit was issued 11041-90000-18640	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75274	16041-20000-22349	24153 W LEMAY ST	91307	12	180B089   383	2034015017	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM	06/24/2016 12:00:00 AM		Permit Finaled	08/10/2016 12:00:00 AM	ADDRESS	34.19076	-118.65259	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 8.12 KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75275	10041-10000-14381	14800 W CORONA DEL MAR	90272	11	123B129   762	4411028010	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.02, 2628.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2010 12:00:00 AM	08/16/2010 12:00:00 AM		Permit Finaled	10/15/2010 12:00:00 AM	ADDRESS	34.03068	-118.51908	T.I. to existing building.  New service, panels, and branch circuits.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75276	17041-20000-01295	221 S CLIFFWOOD AVE	90049	11	132B137   660	4405022014	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2017 12:00:00 AM	01/17/2017 12:00:00 AM		Permit Finaled	01/20/2017 12:00:00 AM	ADDRESS	34.05421	-118.48565	new sfd 600 amp servive.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75277	19041-20000-00700	13551 W CHANDLER BLVD pv1	91401	4	171B157  1144	2344006022	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	03/08/2019 12:00:00 AM	ADDRESS	34.16871	-118.42845	pv1install roof mounted pv system sized 12KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75278	11041-20000-07745	7368 W MELROSE AVE	90036	5	141B181   610	5526020026	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			04/18/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	02/28/2012 12:00:00 AM	PIN	34.08331221	-118.35052976	CHANGE OF USE FROM RETAIL TO RESTAURANT.  SERVICE UPGRADE, NEW HOUSE PANEL, LIGHTING.  FIRE ALARM IS ON A SEPERATE PERMIT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75279	17041-20000-04364	5406 N CALVIN AVE	91356	3	174B117   648	2163003052	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/25/2017 12:00:00 AM	ADDRESS	34.16904	-118.55617	pv1install roof mounted pv system sized 7.6kw standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75280	16041-10000-38594	4371 N EAGLE ROCK BLVD	90041	14	157-5A219 375	5473026013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			Reviewed by Supervisor	11/08/2016 12:00:00 AM	ADDRESS	34.12399	-118.22146	Installation of new roof mounted solar PV array on existing church building.  Total system size = 10.5 kWac.  21 APS YC500i microinverters on three branch circuits connected to 60 amp load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75281	14041-10000-20572	12860 N ENCINITAS AVE	91342	7	222B141   213	2604008038	RA-1	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			07/30/2014 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.3033	-118.47785	permit to be pulled at EPC counter only. Plan check for energy only per 2008 standards. BLDG#13016.10.23480 - TI (E) building for MCDONALDS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75282	12041-20000-15125	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			06/28/2012 12:00:00 AM	06/28/2012 12:00:00 AM		Permit Finaled	09/06/2012 12:00:00 AM	ADDRESS	34.17126	-118.58861	divide conference room into 2 exam room	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75283	13041-10001-03591	6212 N ELMER AVE	91606	2	177B173   352	2336025009	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2013 12:00:00 AM			PC Approved	08/01/2013 12:00:00 AM	ADDRESS	34.18356	-118.37673	Relocation of AC disconnect, meter, and main service panel from north side of the house to south-facing side.  Plan check only. Original description: PV1 2.45kw MICRO INVERTER SINGLE STORY HOUSE. [MIRCRO INVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: REC {REC 245 PE}]. STANDARD PLAN ROOF MOUNTED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75284	16041-20000-35325	4720 N VINELAND AVE	91602	2	168B173   668	2421026006	C2-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			10/05/2016 12:00:00 AM	12/23/2016 12:00:00 AM		Permit Finaled	08/03/2017 12:00:00 AM	ADDRESS	34.15615	-118.37007	service upgrade 800 amps. plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75285	16041-10000-18184	1207 S VERMONT AVE	90006	1	129B197   797	5078028004	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			05/24/2016 12:00:00 AM			PC Approved	06/23/2016 12:00:00 AM	ADDRESS	34.04886	-118.29184	PC for a New fire alarm system for a fully sprinklered building. Scope includes 412 FA devices, 35 control devices, 13 control panels, and 1 fire alarm panel.Note: Permit is under PCIS#13041-10000-34382	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75286	18041-20000-16373	14850 W CASTILLE WAY	91342	7	219B149   648	2611046011	(T)(Q)RAS3-1, C2-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/03/2018 12:00:00 AM		Permit Finaled	11/29/2018 12:00:00 AM	ADDRESS	34.29446	-118.45475	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75287	18041-10000-42414	805 W MANCHESTER AVE	90044	8	097-5A199 203	6032014023	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			11/05/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	33.96022	-118.28728	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75288	15041-20000-34848	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			10/19/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.10158	-118.3062	Plan check for a fire alarm system. Fire alarm system consists of (1) FACP and (2) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75289	12041-10001-03160	4680 W WILSHIRE BLVD 3RD FLOOR	90010	4	132B185    29	5090009020	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			04/17/2012 12:00:00 AM			PC Approved	04/17/2012 12:00:00 AM	ADDRESS	34.0618	-118.33112	DELTA 3 REVISION TO APPROVED T24 ENERGY PLAN FOR TI. REVISION TO T24 CALCULATION AND LIGHTING PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75290	16041-20000-23110	3239 N PASADENA AVE Unit D	90031	1	142-5A223 293	5205006057	RD1.5-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Apartment			06/30/2016 12:00:00 AM	06/30/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	34.08312	-118.21405	PV2.  Install 2.85 kW DC roof mounted PV system.  (10) modules with microinverters.  Zoning clearance obtained under 16041-20000-19398	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75291	15041-10000-17005	8468 N KEWEN AVE	91352	11	108B145  1466	4241037012	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	07/02/2015 12:00:00 AM	ADDRESS	34.2242	-118.38661	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75292	12041-10000-11321	821 S MAIN ST	90014	14	127-5A211 243	5144016047	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/16/2012 12:00:00 AM	10/18/2012 12:00:00 AM		Permit Finaled	03/18/2016 12:00:00 AM	ADDRESS	34.04248	-118.25393	title 24 and energy for a restaurant, ground level , in a three story bldg.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75293	14041-10000-23746	3860 S GRAND VIEW BLVD	90066	11	111B157    88	4235025036	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.0035	-118.42997	Title 24 plan check only.  Total area = 24,860 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75294	15041-10000-14795	1422 W 3RD ST	90732	15	018B193  1376	7452019029	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2964.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM	05/14/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	33.74164	-118.30702	PV1 ROOF MOUNTED STANDARD PLAN. 30 MODULES AND MICRO INVERTER ENPHASE 250. 7.2KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75295	09041-20002-19436	400 N GUNSTON DR	90049	11	138B145   222	4429033025	RE40-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.07416	-118.47031	Change to approved set of plans.  New switch gears, relocating panels.    <<<<New SFD ~ 21,000 Sqr Ft. - 800 A service.  120/240 V 3 phase, panels, equipment, ckts, etc.  P/C is for Power.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75296	19041-20000-10645	21800 W BURBANK BLVD 210	91367	3	174B105    42	2146007122	(WC)PARK-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	09/03/2019 12:00:00 AM	ADDRESS	34.17267	-118.60262	Plan check for Title 24 Energy only in existing space Tenant Improvement  office space. Total area: 3435 sq ft B#19016-10000-03408	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75297	18041-10000-12176	2301 W BELLEVUE AVE	90026	13	139-5A205   5	5402024010	R3-1VL, [Q]R4-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian, Silver Lake	YES	1957.10	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Info Complete	04/09/2018 12:00:00 AM	ADDRESS	34.07417	-118.26931	INSTALLATION OF A NEW METER AND OVERCURRENT PROTECTION FOR EXISTING FIRE PUMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75298	18041-10001-09952	1600 N CAMPUS ROAD	90032	14	157-5A223   1	5476001003	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock, Historic Highland Park	YES	1816.00	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM			PC Approved	11/26/2018 12:00:00 AM	ADDRESS	34.12626	-118.21412	SUPPLEMENTAL FOR READY TO ISSUE A NEW COPY DUE TO LOST STAMPED PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75299	19041-30000-01976	6630 W SUNSET BLVD	90028	13	147A185    75	5547024034	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	10/18/2020 12:00:00 AM	ADDRESS	34.09782	-118.33424	Plan check for a fire alarm system for a 6-story, 40-residential unit mixed-use building. Fire alarm system consists of (1) FACP and (122) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75300	15041-30000-35007	12777 W JEFFERSON BLVD UNIT A	90066	11	102B161    20	4211009037	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			10/20/2015 12:00:00 AM	12/28/2015 12:00:00 AM		Permit Finaled	05/02/2016 12:00:00 AM	ADDRESS	33.9778	-118.41768	Plan check for power and Title-24.  Total area = 29,729 sq. ft.TENANT IMPROVEMENT OF PARTIAL FIRST AND ENTIRE SECOND FLOOR TO EXISTING OFFICE SPACE; NEW TRANSFORMERS AND SUBPANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75301	17041-10000-00275	2333 S FIGUEROA WAY	90007	1	123A203   174	5124028008	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			01/05/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	34.03006	-118.27513	T24 ONLY. REPLACE HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. TOTAL AREA (OUTDOOR) 44775 SQ FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75302	12041-10000-07516	7833 W SUNSET BLVD	90046	4	147B177   967	5551020019	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			04/02/2012 12:00:00 AM			PC Approved	06/06/2012 12:00:00 AM	ADDRESS	34.09823	-118.36022	CHANGE OF USE FROM RETAIL TO BANK; INTERIOR TI +/- 8303 SF  REPLACE EXISTING STOREFRONT WITH NEW AT SAME LOCATION; NEW A/C UNITS ON THE ROOFPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75303	19041-20001-23617	1338-1344 N SYCAMORE AVE	90028	4	147B181  1226	5548023114	RD1.5-1XL	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM			PC Approved	09/17/2019 12:00:00 AM	ADDRESS	34.09542	-118.34231	CHANGES TO APPROVED SET CHANGES TO FEEDER FROM CU TO AL FOR UNITS ONLY.PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75304	16041-10003-25130	15579 W MEADOWGATE ROAD	91436	5	165B141   244	2285003046	R1-1	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.14953	-118.47409	12/29/16Changing the PV system. Plan checking for a point of interconnection to main service panel. Ugrading main panel from 200A to 225A.Note: Permit is paid under PCIS#16041-10000-25130	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75305	18041-20000-22046	4119 S CENTINELA AVE	90066	11	111B157  1193	4231018017	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	Commercial			06/13/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	33.99647	-118.42821	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,524 sq. ft.Note: Building permit has been issued under 14016-10000-08139	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75306	17041-10000-43208	1414 S GRAMERCY PL	90019	10	129B193  1527	5073006021	R3-1	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2213.04	Electrical	Electrical	Commercial			12/01/2017 12:00:00 AM	12/06/2017 12:00:00 AM		Permit Closed	09/19/2023 12:00:00 AM	ADDRESS	34.04567	-118.31287	REMOVE OUTDOOR HALIDE FIXTURES AND REPLACE WITH NEW LED FIXTURES. TITLE 24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75307	18041-20000-38469	3309 N CARSE DR	90068	4	157-5A181 112	2429006041	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/02/2018 12:00:00 AM	ADDRESS	34.12695	-118.35013	pv1install roof mounted pv system sized 7.6KW AC interconected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75308	15041-10000-22199	6300 W WILSHIRE BLVD STE 1700	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM			PC Info Complete	07/13/2015 12:00:00 AM	ADDRESS	34.06319	-118.36591	TI TO AN EXISTING HIGH RISE OFFICE BUILDING. ADDING NEW LIGHITNG NEW CONTROLS TO EXISTING PANELS.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY.  TOTAL SQUARE FOOTAGE 15492.  SCOPE OF WORK TO BE PERFORMED IN SUITE 1700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75309	18041-20000-21023	11726 W SAN VICENTE BLVD Ste 400	90049	11	129B145    65	4265006023	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			06/06/2018 12:00:00 AM			PC Approved	06/06/2018 12:00:00 AM	ADDRESS	34.05328	-118.46625	TI to (E) commercial office space in a highrise building.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75310	15041-20001-12760	16627 W NORDHOFF ST	91343	12	198B137   972	2687024005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			04/28/2015 12:00:00 AM			PC Approved	05/15/2015 12:00:00 AM	ADDRESS	34.23588	-118.4948	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 15 kWac.  3 inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75311	18041-20000-17939	1541 N CAHUENGA BLVD	90028	13	147A187    17	5546013037	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Expired	01/12/2023 12:00:00 AM	ADDRESS	34.09917	-118.3298	Plan check for fire alarm system in existing building. Total Fire alarm devices: 52 and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75312	10041-10000-24738	2029 S CENTURY PARK EAST 31st Floor	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			12/13/2010 12:00:00 AM	12/14/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.05956	-118.41375	TI IN AN EXISTING OFFICE AREA ON THE 31ST FLOOR IN SUITE # 3100. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75313	19041-20000-21048	1332 N LAUREL WAY	90210	5	147B161   411	4355019052	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	11/02/2020 12:00:00 AM		Permit Finaled	12/22/2021 12:00:00 AM	ADDRESS	34.09508	-118.41757	PLAN CHECK FOR  600A SERVICE. SCOPE OF WORK INCLUDES A 600A PANEL, A 9.6 KW EV CHARGER, AND (3) 200A PANELBUILDING PERMIT#17010-20000-03259	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75314	17041-10000-30906	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			08/29/2017 12:00:00 AM	08/29/2017 12:00:00 AM		Issued	08/29/2017 12:00:00 AM	ADDRESS	34.10158	-118.3062	"1 INTERNALLY ILLUMINATED WALL SIGN, 2'6""X8'6"", 21.25SQFT, 10'10"" TO GRADE, TO READ "" OCHA CLASSIC RESTAURANT"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75315	15041-10000-04391	10060 N REMMET AVE	91311	12	204B105   825	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			02/13/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	04/09/2015 12:00:00 AM	ADDRESS	34.25363	-118.60035	Plan check for T-24 only. Remove HID fixtures and replace with new LED fixtures. Total area: 8080 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75316	10041-20000-09079	1816 W 6TH ST	90057	1	133-5A205 350	5142008014	C2-2	Central	Westlake		YES	2089.02	Electrical	Electrical	Commercial			05/14/2010 12:00:00 AM			PC Approved	05/14/2010 12:00:00 AM	ADDRESS	34.0581	-118.27219	revise single line diagram no additional load	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75317	12041-20000-07700	19950 W RINALDI ST	91326	12	210B113   182	2701040023	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.00	Electrical	Electrical	Commercial			04/04/2012 12:00:00 AM	04/04/2012 12:00:00 AM		Permit Finaled	04/13/2012 12:00:00 AM	ADDRESS	34.27535	-118.56939	Changes to 11041-10000-02849Energynew electrical permit	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75318	13041-10001-06609	6840 N RESEDA BLVD	91335	3	183B125   874	2125010019	[Q]C2-1L-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			06/10/2013 12:00:00 AM	06/13/2013 12:00:00 AM		Permit Closed	12/05/2014 12:00:00 AM	ADDRESS	34.19506	-118.53584	MODIFICATION TO APPROVED SET OF PLANS UNDER APPLICATION NUMBER 13041-10000-06609.DELTA 5 CHANGES CLOUDED ON PLANS.************************************************13041-10000-06609 DESCRIPTION: PLAN CHECK FOR TITLE 24. TENANT IMPROVEMENT IN AN EXISTING STARBUCKS (1668 SQUARE FEET) REMINDER: ALL TITLE 24 PERMITS SHALL BE OBTAINED THROUGH THE ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75319	18041-20000-30825	18460 W ROSCOE BLVD	91325	12	192B125   934	2102001018	(Q)C2-1L	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			08/14/2018 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	01/15/2020 12:00:00 AM	ADDRESS	34.22046	-118.53569	Plan check for Title 24 only. Project site is a 1st floor corridor of an existing commercial building. Project scope is an interior remodel. Total lighting area = 1,281 sq. ft.Note: Building application has been generated under 18016-20000-26164	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75320	17041-10000-18145	22700 W SHERMAN WAY	91307	12	183B097   111	2024019005	A1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Permit Finaled	02/21/2018 12:00:00 AM	ADDRESS	34.20071	-118.62196	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75321	11041-10002-20662	1430-1434 S ELKGROVE CIR BLDG 13	90291	11	111B149   486	4243001033	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			01/10/2012 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	05/06/2014 12:00:00 AM	ADDRESS	34.00125	-118.45783	LINCOLN PLACE APARTMENT PROJECT. Addition of one panel for garage with 5 circuits, all floor plans to be checked. changes made to previously approved set.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75322	11041-20000-06668	2018 N GRIFFITH PARK BLVD	90039	4	147A205   119	5431005***	RD2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	Apartment			04/04/2011 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	07/11/2011 12:00:00 AM	ADDRESS	34.09779	-118.27337	replace fire alarm panel	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75323	12041-20000-16744	10223 N LASAINE AVE	91325	12	204B129   222	2734029033	RE11-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	1 or 2 Family Dwelling			07/18/2012 12:00:00 AM	08/30/2012 12:00:00 AM		Permit Finaled	11/29/2012 12:00:00 AM	ADDRESS	34.25631	-118.5124	New photovoltaic system and service panel upgrade for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75324	15041-30000-43757	850 S HOPE ST	90017	14	127-5A209  28	5144020196	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/29/2015 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	04/10/2019 12:00:00 AM	ADDRESS	34.04528	-118.25988	Plan check for power and energy.  Total area = 4,950 sq. ft.     New first time retail tenant in first floor of new parking structure.  Tenant space has one 400 A panel which feeds two subpanels.  New HVAC, receptacles and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75325	19041-10000-30269	23838 W KITTRIDGE ST	91307	12	180B089   395	2034023051	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	Commercial			08/05/2019 12:00:00 AM	04/23/2020 12:00:00 AM		Permit Finaled	05/27/2020 12:00:00 AM	ADDRESS	34.19077	-118.64617	$0 Permit fees due, per Assembly Bill 1414. PV2, NEW ROOFTOP MOUNTED SYSTEM ON A EXISITING COMMERCIAL BUILDING, SYSTEM SIZE IS 53.655KWdc/45KWac. SCOPE OF WORK IS 147 MODULES (CANDIAN SOLAR KUMAX CS3U-365P), LEADING TO THREE INVERTERS AT DIFFERENT SIZES (FRONIUS SYMO 12.5, FRONIUS SYMO 15, AND FRONIUS 17.5).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75326	14041-20000-08466	21820 W BURBANK BLVD #269	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/01/2014 12:00:00 AM			PC Approved	04/01/2014 12:00:00 AM	ADDRESS	34.17228	-118.6032	T.I. to existing building on 2nd floor.  Install and relocate general/emergency lighting.  Plan check for energy only.Note: Permit is under 14041-90000-05619	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75327	14041-10000-16718	11150 W SANTA MONICA BLVD Suite 450	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM			PC Approved	06/23/2014 12:00:00 AM	ADDRESS	34.04704	-118.44563	Title-24 plan check only.  Total area = 2,189.1 sq. ft.TI to existing commercial highrise.  Replace lighting using existing circuits and move wall partitions.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75328	17041-10000-41364	134 E GAGE AVE	90003	9	105B205   941	6006014024	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.20	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM	11/15/2017 12:00:00 AM		Issued	11/15/2017 12:00:00 AM	ADDRESS	33.98229	-118.27255	PC FOR ROOF MOUNTED PV ON SFD. SYSTEM SIZE 3.8KWAC  3.7KWDC SCOPE INCLUD 10 MODULES WITH OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75329	16041-20000-15550	10850 W BLOOMFIELD ST	91602	4	165B173   487	2423019112	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Apartment			05/03/2016 12:00:00 AM	05/03/2016 12:00:00 AM		Permit Finaled	06/21/2017 12:00:00 AM	ADDRESS	34.14907	-118.36695	Plan check for a fire alarm system for a 3-story, 28-unit apartment building. System consists of (1) FACP, (1) anunciator, and (69) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75330	14041-20000-32960	11828 W PICO BLVD	90064	11	123B149   924	4259039005	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			11/25/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.0303	-118.44794	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NO CHANGE IN OCCUPANCY.  5533 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75331	15041-10000-18749	12473 W OSPREY LANE	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			06/16/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	10/13/2015 12:00:00 AM	ADDRESS	33.97916	-118.41034	NEW FIRE ALARM SYSTEM FOR BUILDING TYPE 'B'. EACH BUILDING HAS ITS OWN DEDICATED FIRE ALARM CONTROL PANEL WITH 57 DEVICES. ALL BUILDING TYPE 'B' ARE ON ONE SET OF PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75332	10041-10000-06968	14006 W RIVERSIDE DR # 216	91423	2	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/16/2010 12:00:00 AM	05/11/2010 12:00:00 AM		Permit Finaled	06/16/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	TENANT RENOVATIONS AT THE VANS SHOE STORE AT THE FASHION SQUARE MALLPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75333	12041-20000-29338	8900 N DE SOTO AVE BLDG 102	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/05/2012 12:00:00 AM	12/11/2012 12:00:00 AM		Permit Finaled	04/21/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	Plan check for power only. Replacement of two 600A panels and eight 0-200A panels. Replacement is one-to-one with no change in load (no load calcs or voltage drops necessary).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75334	15041-20000-02377	18901 W VINCENNES ST	91324	12	198B121   207	2762014007	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/26/2015 12:00:00 AM	ADDRESS	34.24108	-118.54514	Roof mounted PV system with total system size 5KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75335	14041-20000-05212	5324 N SEPULVEDA BLVD	91411	4	172-5A145  53	2250004006	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1288.01	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	06/18/2014 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.16751	-118.46576	NEW 7 UNIT  apartment With 2-CAR GARAGE PER UNIT. fully  sprinklered NFPA 13RPC FOR POWER. NEW TOWNHOMES. PER BUILDING SUBMITTAL. PLAN CHECK IN ACCORDANCE TO 2008 NEC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75336	17041-10001-35605	6433 W WARNER DR	90048	5	135B173   907	5088013015	R1-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2019 12:00:00 AM			PC Approved	07/03/2019 12:00:00 AM	ADDRESS	34.06293	-118.36939	Changes to an approved set of plans. Changes include revising single line diagram to reflect as built. Also adding AC disconnect for Tesla Storage batteries.Note: Permit fees are under pcis 17041-10000-35605(((((PC for two energy storage systems in SFD with existing PV and load center.Total energy storage capacity is 27kWh.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75337	19041-10000-45156	445 S FIGUEROA ST 15TH FLR	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Finaled	03/31/2020 12:00:00 AM	ADDRESS	34.05295	-118.25675	ENERGY PLAN CHECK ONLY.  AREA OF SCOPE IS 360SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75338	16041-20000-37153	21021 W VENTURA BLVD ste 200-210	91364	3	171B105   135	2167001016	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	01/24/2017 12:00:00 AM	ADDRESS	34.16688	-118.59113	ti to an existing commercial building.  adding new lighitng new controls to existing panels.  plan check for energy and em power only.  total square footage 8852.  scope in suite 200 and 210	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75339	17041-20000-09544	5958 N VINELAND AVE #B, C	91601	2	177B173  1228	2415001001	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			03/24/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.1792	-118.3701	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR MASSAGE PARLOR. Change of use with non structural interior T.I. from retail to massage parlor. 874 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75340	15041-10000-32753	452 N SAN FERNANDO ROAD	90031	1	141A219   219	5447003900	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			10/02/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	06/16/2016 12:00:00 AM	ADDRESS	34.07966	-118.22438	T24 ONLY. LIGHTING UPGRADE FOR PARKING LOT AND GARAGE. COMMERCIAL BUILDING . VTOTAL AREA 297445 SQ FTNO EMERGENCY OR EGRESS LIGHTING..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75341	16041-10000-16421	4925 W ADAMS BLVD	90018	10	123B181   976	5049001042	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2197.00	Electrical	Electrical	Commercial			05/10/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	PIN	34.03279197	-118.34781562	INSTALL NEW FIRE ALARM SYSTEM ON A CHILD DAYCARE FACILITY. (1) FA PANEL   (2) COMM. PANEL       (21) F.A. DEVICES B# 15016-10000-16097	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75342	16041-20000-00541	12181 W BLUFF CREEK DR #203	90094	11	102B161  1150	4211010112	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	08/01/2016 12:00:00 AM	ADDRESS	33.97788	-118.40638	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 565 sq. ft.Note: Building permit has been pulled under 15016-10000-21160	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75343	17041-10005-33475	11924 W FOOTHILL PL	91342	7	210B165   107	2532012038	C2-1VL-CUGU, P-1VL-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.08	Electrical	Electrical	Commercial			12/24/2018 12:00:00 AM			PC Approved	12/24/2018 12:00:00 AM	PIN	34.27497571	-118.39643615	SUPPLEMENTAL CHANGES TO APPROVED SET DELTA 4 ONLY. CHANGING BUS RATING FROM 225 TO 200 ON PANEL A, B, AND C.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75344	18041-10000-43832	8314 W 3RD ST	90048	5	138B173   892	5511031036	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/15/2018 12:00:00 AM			PC Info Complete	01/08/2019 12:00:00 AM	ADDRESS	34.07259	-118.37057	ENERGY PLAN CHECK FOR A RETAIL TO RESTAURANT, SCOPE OF WORK INCLUDES 1300 SQFT WITH NEW LIGHTING AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75345	17041-20000-12614	3515 W HYDE PARK BLVD	90043	8	105B185  1231	4006007036	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2349.02	Electrical	Electrical	Apartment			04/18/2017 12:00:00 AM			Reviewed by Supervisor	05/17/2017 12:00:00 AM	ADDRESS	33.98072	-118.33417	new fire alarm system 136 devices with new facp.submittal requested by applicant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75346	19041-20000-11304	18226 W SEPTO ST	91325	12	201B125    58	2731023008	RA-1	North Valley	Northridge	Northridge East		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.25079	-118.53074	INSTALLATION OF A NEW ROOFTOP PV SYSTEM. 8.45KW DC/7.6KW AC. SCOPE OF WORK INCLUDES (26) PV MODULES WITH SE P400 OPTIMIZERS, AND A SE7600H INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75347	16041-10000-44943	2946 E 11TH ST	90023	14	118-5A221  11	5169007016	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			12/22/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	02/10/2017 12:00:00 AM	ADDRESS	34.02077	-118.21473	PC for energy only; Outdoor title 24. Remove HID fixtures and replace with new LED ones. Area: 3600.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75348	17041-10000-44228	18426 W NORDHOFF ST	91325	12	195B125     6	2769001032	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	12/08/2017 12:00:00 AM		Permit Finaled	12/28/2017 12:00:00 AM	ADDRESS	34.23523	-118.53468	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75349	13041-10004-10268	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	33.94286	-118.39982	Delt 9 revisions to permitted set of plans : new branch circuit with 45KVA transformer to supply a State-approved trailer to be used as offices; installing data outlets; relocating lunch room and ITA room and relocating luminaires in  those rooms .Replacing baggage handling systems for terminal 7 of LAX and upgrading TSA baggage inspection system.  Power and energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75350	18041-10000-39436	19191 S VERMONT AVE 10TH FLOOR	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	11/09/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	Design build. Energy plan check for am office T.I located on the 10th floor. Scope cover new lighting in the reception area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75351	10041-10013-05975	380 W WORLD WAY TBIT	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM			PC Approved	12/24/2013 12:00:00 AM	PIN	33.94094587	-118.40577128	REVISED LOAD ON FEEDER # 10 OF 4CSIPC DIST BD AND FEEDER # 9 CORRECTED TYPO ON AMP RATING OF THE CB(((((((((single line diagrams with existing switchboards and distribution boards supplying tenant panel boards at the North Core  Concessions. Review was requested such that Westfield will have knowledge which feeders supply a tenant space. Additional plans will include design and actual loads for each tenant space to be used by the plan checker to verify a panelboard or distribution board is not overloaded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75352	15041-20000-13947	7500 N GLENOAKS BLVD	91504	2	186B181    30	2401042011	(Q)R4-1, (Q)R4-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1021.04	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.20696	-118.3417	PC FOR FIRE ALARM SYSTEM. TOTAL OF 212 DEVICES. NEW FIRE CONTROL PANEL. ASSOCIATED ANNUNCIATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75353	10041-20000-19683	1990 S BUNDY DR suite 100	90025	11	123B149   350	4259020014	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/04/2010 12:00:00 AM	10/26/2010 12:00:00 AM		Permit Finaled	12/26/2010 12:00:00 AM	ADDRESS	34.03419	-118.45559	energy plan check suite 100	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75354	13041-20000-31326	110 S FAIRFAX AVE	90036	4	138B177  1127	5512003031	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			11/08/2013 12:00:00 AM	01/30/2014 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.07371	-118.36119	T. I. FROM RETAIL TO RETAIL. NEW 800A DISTRIBUTION. 20000 SQ FT ENERGY USING TAILORED METHOD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75355	19041-20000-15379	555 S FLOWER ST 37th flr	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	01/28/2020 12:00:00 AM	ADDRESS	34.05048	-118.25755	ti to an existing high rise building, pantry.  adding new lighting new controls to new panel.  newly connected load < 400 amps.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75356	18041-10001-47284	5401 N OSTROM AVE	91316	5	174B133   811	2258004004	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.16945	-118.50704	EXPEDITE FOR PV PLAN PER APPLICANT REQUESTNEW ROOFTOP 15.2 KW AC PV SYSTEM FOR (E) SFD, SCOPE INCLUDES (60) PANASONIC PV MODULES WITH OPTIMIZERS, AND (2) 7.6 KW AC SOLAREDGE SE7600H-US INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75357	18041-10000-37429	5353 W IMPERIAL HWY STE200/300	90045	11	087B173    66	4129037037	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/01/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/13/2018 12:00:00 AM	ADDRESS	33.93112	-118.37375	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75358	13041-10000-31010	707 E 4TH PL	90013	14	127-5A215  61	5163012015	M3-1	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	12/27/2013 12:00:00 AM		Permit Finaled	02/19/2014 12:00:00 AM	ADDRESS	34.04542	-118.23748	pc for power and energy. fully rated-no series rating allowed.CHANGE OF USE FROM RETAIL/MARKET TO ARCADE, BAR & DANCE HALL. AND UNROOFED OUTDOOR DINING AREA. FULL PLAN CHECK; TOTAL ILLUMINATED AREA TO BE 4621 SQ FT (INDOOR + OUTDOOR). APPLICANT RETURNED AND REQUESTED PLANS TO BE EXPEDITED AND WAS CHARGED UNDER SUBMITAL-2. BLDG PERMIT UNDER 130-41-10000-10421CONDUIT-ONLY PERMIT FILED ON 12/13/13 , UNDER PC# 13041-10000-34783	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75359	15041-20000-43176	9120 W ORIOLE WAY	90069	4	147B169   820	5560006014	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM			Reviewed by Supervisor	01/29/2016 12:00:00 AM	ADDRESS	34.09669	-118.38872	Plan check for power only. New 3-story single family dwelling with basement and attached garage. 800A service 120/240 3phase 4-wire.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75360	16041-10000-13055	1150 S OLIVE ST SUITE1300	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	05/10/2016 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.03962	-118.26181	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 3330.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75361	19041-20000-22473	8362 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM				PV1.  Install 2.8 kW roof mounted grid tied PV system for new home construction.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75362	14041-10000-22514	20826 W LASSEN ST	91311	12	201B109   116	2748004058	MR1-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.24984	-118.58717	T24, REPLACE HID LIGHT FIXTURES WITH NEW FLUORESCENT FIXTURES. TOTAL AREA 7410 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75363	17041-10000-11111	12265 N SAN FERNANDO ROAD	91342	7	219B149   850	2611008004	C2-2D-CPIO	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Issued	04/06/2017 12:00:00 AM	ADDRESS	34.2931	-118.45188	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  46525 SQ FT.  OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75364	14041-20000-33173	140 S VAN NESS AVE	90004	4	138B189  1150	5516011004	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	34.07188	-118.31546	Roof mounted PV system with system size 9KW.Note: Solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75365	17041-10001-23801	912 S 4TH AVE	90291	11	108B145   604	4239010022	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	Apartment			07/14/2017 12:00:00 AM			PC Approved	08/10/2017 12:00:00 AM	ADDRESS	33.99357	-118.47151	EXPEDITE PER APPLICANT REQUEST.(((((PV2. NEW SOLAR SYSTEM FOR AN EXISTING MULTI-FAMILY RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.0KWac.(7)MODULES-TRINA SOLAR#TSM-300DD05A.18(1)INVERTER-ABB#PVI3.0-OUTD-S-US-Z-A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75366	19041-10000-22285	13227 N GLADSTONE AVE	91342	7	225B157   700	2509016019	(Q)C2-1, C2-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	Commercial			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.31115	-118.42909	PC FOR A NEW FIRE ALARM SYSTEM FOR A NEW HEALTH CLUB. SCOPE INCLUDES 2 FA PANELS, AND 29 FA DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75367	16041-10001-41785	1882 S COCHRAN AVE	90019	10	126B177   720	5067020018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.04209	-118.35452	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<<PV INSTALL NEW 23.544 KW DC/23.040 KW AC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(72) AC MODULES: SPR-E20-327-C-AC>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75368	15041-20001-17238	14859 W BESSEMER ST #6	91411	6	177A149    45	2241024016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			07/27/2015 12:00:00 AM	07/27/2015 12:00:00 AM		Permit Finaled	09/14/2015 12:00:00 AM	ADDRESS	34.18089	-118.45722	07-27-2015 Plan check for lost original set of plans, Title 24 only. [[[[[Plan check for Title 24 only retail space. Total area:1450 SF]]]]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75369	12041-10000-13023	1540 E ALCAZAR ST 109-110,113	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			06/06/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.06338	-118.20434	PLAN CHECK POWER AND ENERGY FOR INTERIOR REMODEL TO CONVERT SMALL OFFICES (#109, 110, 113) TO CLASSROOMS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75370	19041-20000-13296	6644-6646 N NESTLE AVE	91335	3	180B125   274	2125019003	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			04/11/2019 12:00:00 AM	04/12/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.19159	-118.53067	INSTALLATION OF A ROOFTOP PV SYSTEM ON EXISTING SFD TO POWER ADJACENT ATTACHED ACCESSORY DWELLING UNIT. SYSTEM SIZE IS 2.17KW DC/1.61 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR MSE310SQ8T PV MODULES WITH (7) ENPHASE IQ 6 MICROINVERTERS 240V	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75371	15041-10000-04768	9020 N RESEDA BLVD SUITE 102	91324	12	195B125    51	2769001031	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Info Complete	03/16/2015 12:00:00 AM	ADDRESS	34.2346	-118.53587	PC FOR POWER AND ENERGY. FIRST TIME TENANT, NO HIGH RISE BUILDING. TOTAL AREA 1275 SQ FT.PER INSPCTOR REQUEST FOR FULL PLAN CHECK FOR APPLICATION # 14041-10000-35081.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75372	10041-10003-22406	1360 S WESTWOOD BLVD	90024	5	132B153   766	4325016015	C4-1VL-POD	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			09/29/2011 12:00:00 AM			PC Approved	09/29/2011 12:00:00 AM	ADDRESS	34.05594	-118.44192	CHANGES TO PERMITTED SET OF PLANS; CHANGES ARE SHOWN AS CLOUDED ON THE REVISED SHEETS OF THE PLAN((((((((((TENANT IMPROVEMENT OF EXISTING RETAIL BUILDING-NEW ROSS DEPARTMENT STORE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75373	18041-20000-10312	4735 N SEPULVEDA BLVD	91403	4	168B145   647	2264001043	C2-1L, R4-2L, [T][Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	34.15623	-118.46637	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OUTDOOR LIGHTING AT THE GRAND APARTMENTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75374	19041-10000-46962	7560 WORLD WAY	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			11/14/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	03/30/2020 12:00:00 AM	ADDRESS	33.94055	-118.42896	PC FOR A NEW FIRE ALARM SYSTEM (DELTA GSE), SCOPE OF WORK IS ONE NEW FIRE ALARM PANEL WITH 69 DEVICES, AND TWO REMOTE POWER SUPPLIES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75375	13041-20000-22953	1124 S MOTT ST	90023	14	121-5A221  42	5170004028	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2047.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	10/01/2013 12:00:00 AM		Permit Finaled	06/23/2014 12:00:00 AM	ADDRESS	34.02825	-118.21576	New 3.9kw rooftop PV system for an existing single family dwelling.  System is UNGROUNDED.  Plan check is for PV System only, not for service upgrade or for derating of main breaker.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75376	17041-20000-19697	221 S FIGUEROA ST ste 500	90012	14	132A209    92	5151001024	C4-4D	Central	Central City	Downtown Los Angeles		2075.01	Electrical	Electrical	Commercial			06/12/2017 12:00:00 AM			PC Approved	06/12/2017 12:00:00 AM	ADDRESS	34.05628	-118.25373	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75377	15041-10002-14972	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2015 12:00:00 AM	10/19/2015 12:00:00 AM		Permit Expired	11/14/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	"(((10-16-2015: CHANGES MADE TO APPROVED SET. DOING WORK IN THE ELEVATOR LOBBY)))SUPP TO PERMIT # 15041-10000-14972 TO ADD 200 AMP POWER, T.I. ELECTRICAL OUTLETS FOR MACYS GROUND FLOOR""COMPLY WITH DEPARTMENT ORDER effective date04/28/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75378	15041-20001-40750	350 W 5TH ST SUITE 209	90731	15	015B201    39	7455014035	C2-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	33.73981	-118.28471	Plan check for Title 24 only for Medical office. Total area: 1,820 sqft. Permit fees paid under 15041-40000-40750 and 15041-20002-40750.  (((((INSTALL 40 OUTLETS FOR OFFICE)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75379	17041-20001-17089	2136 W WASHINGTON BLVD	90018	10	126B193   944	5074033042	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.02	Electrical	Electrical	Commercial			04/18/2018 12:00:00 AM			PC Approved	04/18/2018 12:00:00 AM	ADDRESS	34.03974	-118.30707	4/18/2018CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOPTED DELTA 3.  CHANGES INCLUDE DIFFEREWNT LIGHT FIXTURES AND REVISED ENERGY CALCULATIONS.  THIS IS PLAN CHECK ONLY.(((PC for power and energy for change of use TI project for new adult day care center. Scope includes having exisiting panels with new circuit and new equipment. Total affected area is 21750 sqft. Plan checker to verify outoor area during verification.building #16016-10000-22539)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75380	19041-10000-19750	9640 N TOPANGA CANYON BLVD	91311	12	201B101   430	2746018011	QMR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Issued	05/24/2019 12:00:00 AM	ADDRESS	34.24533	-118.60691	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75381	14041-20000-02634	10828 W MOORPARK ST	91602	4	165B173   366	2423015001	R3-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1432.00	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	34.15023	-118.36656	PC FOR T24 ENERGY ONLY. NEW PERMIT TO BE ISSUED FROM THIS APPLICATION, PERMIT ALREADY EXISTING ON THE JOB. NEW LIGHTING FOR OUTDOOR OF CHURCH. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75382	19041-20000-00812	22732 W CASS AVE	91364	3	168B097    61	2076001024	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1374.02	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Permit Finaled	02/19/2019 12:00:00 AM	ADDRESS	34.16025	-118.62117	PV1.  Install 6.40 kW roof mounted grid tied PV system on main house and detached garage, interconnecting with (E) service on detached garage.  (20) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75383	13041-20000-15380	990 W 190TH ST Suite 120	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/12/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	33.85813	-118.29505	T24 FOR EXISTING OFFICE SPACE. USING EXISTING CIRCUITS FOR THE LIGHTING, JUST REPLACING AND RELOCATING FIXTURES. SCOPE OF WORK ON THE FIRST FLOOR SUITE 120. 4984 SQRFT. PERMIT HAS BEEN PULLED UNDER APPLICATION#: 13041-90000-17417.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75384	13041-10000-05351	14141 W VENTURA BLVD #2	91423	4	165B153  1091	2265020025	(T)(Q)C2-1VL, (T)(Q)R3-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			03/01/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	10/23/2013 12:00:00 AM	ADDRESS	34.14992	-118.44152	PLAN CHECK FOR POWER AND EMERGENCY. FIRST TIME TENANT.  ISLANDS RESTAURANT. SUITE #2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75385	19041-20000-44386	4070 N BENEDICT CANYON DR	91423	4	162B157    73	2272023014	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Issued	10/30/2019 12:00:00 AM	ADDRESS	34.14388	-118.43249	Plan check for PV roof mounted system and Energy Storage System, PV system size: 3.78KW with 12 PV Modules and 1 inverter(3.8KW), (3) Tesla PowerWall 2.0. Energy system size: 40.5KWh.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75386	17041-10000-07350	1530 E ADAMS BLVD	90011	9	117A213   254	5118015009	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/08/2017 12:00:00 AM		Permit Finaled	03/21/2017 12:00:00 AM	ADDRESS	34.01462	-118.24609	Plan check for PV roof mounted system. System size: 3.8kW with 17 modules and 1 inverter(3.8kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75387	14041-20000-33531	3354 N WRIGHTWOOD DR	91604	2	159B173   356	2380038008	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	06/13/2015 12:00:00 AM	ADDRESS	34.13238	-118.37327	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1Install a roof-mounted solar array on a SFD. Interconnect with a 400A MSP.System size: 11.825kW. Ungrounded system.55 EnPhase M215-IG microinverter with 55  250W pv modules across 6 strings (10+9+10+9+9+8).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75388	15041-20000-37903	13710 W FOOTHILL BLVD	91342	7	222B153    63	2509014902	RA-1	North Valley	Sylmar	Sylmar		1061.14	Electrical	Electrical	Apartment			11/10/2015 12:00:00 AM			Corrections Issued	12/10/2015 12:00:00 AM	ADDRESS	34.30854	-118.43227	New apartement 42 unit, MS 1200A. 3 story living spaces, 1 grade level garage. 4 typical units.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75389	12041-20000-09711	4720 S LINCOLN BLVD	90292	11	105B153   149	4224014018	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	05/01/2012 12:00:00 AM		Permit Finaled	08/16/2012 12:00:00 AM	ADDRESS	33.98008	-118.4382	Tenant improvement. Plan check for energy and emergency lighting. Small dog grooming shop. 2 story commercial building. 4163 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75390	12041-10000-16024	6374 W SUNSET BLVD	90028	13	147A187   590	5546015043	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.00	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	09/07/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	34.09768	-118.32839	TENANT IMPROVEMENT TO EXISTING RESTAURANT , ADD OUTDOOR DININNG AREA, New 150kva transformer and 400A panel with subpanels and lighting.  Maximum Occupancy load is 110.  Full Plan Check for Power and Energy.  (Fees are adjusted to fit applicants pre-cut check, additional fees required.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75391	17041-10001-26318	5842 S VERMONT AVE	90044	9	108B197  1673	6004001031	[Q]C2-1	South Los Angeles	South Los Angeles	Voices of 90037		2371.01	Electrical	Electrical	Commercial			12/11/2017 12:00:00 AM			PC Approved	12/11/2017 12:00:00 AM	ADDRESS	33.98793	-118.29128	PC only. Revision to approved set per applicant request. All changes under delta 1. Scope includes revision to circuit feeding Rtu- 2TI TO RETAIL STORE. NEW SPRINT STORE. PC FOR T24 ENERGY ONLY. LIGHTING UPGRADES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75392	14041-20001-30447	18709 W RUNNYMEDE ST	91335	3	186B121   504	2118008010	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			PC Approved	11/12/2014 12:00:00 AM	ADDRESS	34.20576	-118.54089	PV1 SFD. TOTAL SYSTEM SIZE 7.74KW AC USING 36 MODULES. USING ENPHASE M215. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75393	15041-20000-18636	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	34.18686	-118.37207	Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 18,725 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75394	14041-10001-00072	1411 W 190TH ST #675	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Finaled	02/13/2014 12:00:00 AM	ADDRESS	33.85852	-118.30317	Ti in an existing office. 6th floor of a highrise bldg. EPC is for T24 and emergency. (permit was issued under 14041-40000-00072)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75395	15041-20000-38519	515 S FLOWER ST 40TH FLR	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM	12/21/2015 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	ADDRESS	34.05134	-118.25661	INTERIOR TENANT IMPROVEMENT TO (E) OFFICE. CONSTRUCT NON BEARING PARTITIONS, CEILING, MILLWORK AND FINISHES. PC for Energy only, total area: 2,318sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75396	17041-10000-05066	14001 W OSBORNE ST	91331	6	195B153   210	2642031021	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.23346	-118.43824	T-24, PC FOR ENERGY ONLY. REPLACE HID FIXTURES WITH NEW LEDs FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 14225 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75397	13041-10001-26299	23368 W BURBANK BLVD	91367	3	174B093   373	2044001001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			09/23/2013 12:00:00 AM			PC Approved	10/22/2013 12:00:00 AM	ADDRESS	34.17171	-118.63605	][][]EXPEDITED PER APPLICANT REQUEST[][][][PV1 ROOF-MOUNTED SOLAR ARRAY , INTERCONNECTING WITH 200A MAIN; WORK DONE ON A NON STANDARD PLAN. 5 TOTAL STRINGS; LOAD CENTER WILL BE USED; SYSTEM SIZE IS 14KW DC WITH (56) MODULES: TRINA #TSM-250PA05.18(2) POWER-ONE #AURORA PVI-6000-OUTD-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75398	15041-10001-11690	2945 S 6TH AVE	90018	8	120B193   443	5053016018	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM			PC Approved	07/21/2015 12:00:00 AM	ADDRESS	34.02815	-118.32371	Expedited plan check per applicant request.  PV1.  CENTRAL STRING INVERTER STANDARD PLAN SYSTEM SIZE 3.6KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75399	15041-10000-17067	12508 W OSPREY LANE #2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM			PC Approved	06/03/2015 12:00:00 AM	ADDRESS	33.97856	-118.41138	PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 2 SIZED 1.84KW INTERCONNECTED WITH MSP.PERMIT FEES PAID UNDER APPLICATION NUMBER 14041-20000-19575.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75400	11041-10000-11209	13055 W BLUFF CREEK DR	90094	11	102B157   339	4211026013	C2(PV), R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Expired	06/25/2013 12:00:00 AM	ADDRESS	33.97068	-118.42335	Installing one 100 amps panel and new service in playa vista , level VI gas to power a computer CLASS I DIV II GROUP D>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75401	10041-10000-05140	210-216 W 5TH ST	90013	14	129A211   112	5149034006	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM			PC Approved	03/23/2010 12:00:00 AM	ADDRESS	34.04754	-118.25015	T-24 and Emergency Lighting in Tenant Lease Spaces.  The electrical permit is existing, see 09041-10000-23768.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75402	10041-10000-23380	4811 N WHITSETT AVE	91607	2	168B165   449	2357031014	C4-1VL, P-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM			PC Approved	11/22/2010 12:00:00 AM	ADDRESS	34.15815	-118.40551	T24 lighting plan check for beauty salon.  A supplemental permit for the original application, # 10041-10000-21724, will be issued.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75403	17041-20002-22147	17114 W DEVONSHIRE ST	91325	12	204B133   209	2694001047	CR-1VL, P-1VL	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/26/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.25734	-118.50614	02/09/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 3. There has been an addition of loads and lighting control revisions.*****Previous Work Description*****FULL PC TO A  T.I TO  (E) 2ND FLOOR MEDICAL OFFICE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES IN A TREATMENT ROOM WITH NO INVASIVE EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75404	11041-10000-26819	10250 W SANTA MONICA BLVD #175	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/15/2011 12:00:00 AM			Corrections Issued	12/15/2011 12:00:00 AM	PIN	34.0586034	-118.41904766	T.I. to an existing retail space in the Westfield Century City Mall.  Ste 175.    PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75405	18041-10001-45490	11101 N SALT LAKE AVE	91326	12	210B121   397	2717002037	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2018 12:00:00 AM			PC Approved	12/13/2018 12:00:00 AM	ADDRESS	34.27129	-118.54447	EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75406	17041-20002-23031	15900 W HARVEST ST	91344	12	213B141   255	2666007010	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM			PC Approved	08/16/2017 12:00:00 AM	ADDRESS	34.27797	-118.47825	"8.16.2017 - Plan check for modifications to approved set. Update roof layout. Update location of MSP on roof plan. Update single line diagram to show that main panel loads were relocated to new subpanel (load calc. included). Incorrect system size in work description of master permit - AC power is 9.6kW, performance meter is not required. Work description of master permit (#17041-20000-23031) should read:""PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 9.6KW."""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75407	17041-30000-45857	329 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM	12/21/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	33.77303	-118.27884	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,600 sq. ft.Note: Building permit has been issued under 17016-10000-22496	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75408	17041-10000-11102	4122 N GLENALBYN DR	90065	1	145-5A223  16	5465022900	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	34.09509	-118.21209	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  31800 SQ FT.  OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75409	16041-20000-32785	6646 N BECK AVE	91606	2	180B169   394	2320023004	RD1.5-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Apartment			09/15/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	03/13/2017 12:00:00 AM	ADDRESS	34.19159	-118.38327	Plan check for installation of roof-mounted solar array on triplex for single unit. Interconnect with 100A service. 2.88kW ungrounded system. (12) EnPhase M250 microinverters. (12) 285W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75410	17041-20001-40205	6927 N REMMET AVE #C	91303	3	183B105   756	2138007009	R3-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Apartment			11/07/2017 12:00:00 AM			PC Approved	03/28/2018 12:00:00 AM	ADDRESS	34.19636	-118.6004	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on 3-unit apartment (unit #C).3kW ungounded system. (9) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75411	18041-20000-07189	3733 W SUNSET BLVD	90026	13	145-5A203 467	5429021036	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake		1954.00	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Issued	03/15/2018 12:00:00 AM	ADDRESS	34.09096	-118.27836	PLAN CHECK FOR TITLE 24 ONLY FOR - NON STRUCTURAL TENANT IMPROVEMENT TO RETAIL STORE FOR NON HIGHRISE BUILDING - TOTAL AFFECTED AREA = 1474 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75412	15041-20001-05934	6855 N TUJUNGA AVE	91605	2	183B173   210	2320003002	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM			PC Info Complete	07/09/2015 12:00:00 AM	ADDRESS	34.19546	-118.37923	CHANGES TO APPROVED SET OF PLANS. UPGRADING SERVICE TO 1200 AMPS.Power plan check for 800 A service upgrade in existing commercial building. Plan approve per Elie.M	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75413	19041-20000-31368	656 W SOLANO AVE	90012	1	139-5A217  72	5415029016	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Historic Cultural North	YES	2060.10	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	08/12/2019 12:00:00 AM		Permit Finaled	09/09/2019 12:00:00 AM	ADDRESS	34.07672	-118.23332	Plan check for PV roof mounted system, PV system size: 11.05KW DC, 10.0KW AC with 34 PV Modules and 1 inverter(10.0KW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75414	17041-10002-38943	11911 W WESTMINSTER PL	90066	11	114B153    17	4249017020	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM			PC Approved	03/21/2018 12:00:00 AM	ADDRESS	34.01261	-118.43229	03-21-2018 Changes to an permitted set of plan. Changes include install fuse disconnect for Energy Storage System(Tesla Battery). Changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75415	13041-10000-12015	10400 W WILSHIRE BLVD	90024	5	135B157   182	4327001012	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			05/08/2013 12:00:00 AM			PC Approved	05/22/2013 12:00:00 AM	ADDRESS	34.0666	-118.42904	PLAN CHECK FOR TITLE 24 TENANT IMPROVEMENT FOR CLASSROOMS AND RESTROOMS. SCOPE OF WORK < 400A. HALLWAYS/CORRIDORS AND EMERGENCY LIGHTING ARE NOT IN SCOPE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75416	17041-20003-19660	11500 W CANTON DR	91604	2	159B169   378	2377016014	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM			PC Approved	11/13/2017 12:00:00 AM	ADDRESS	34.13274	-118.38388	11/13/17changes to an approved set of plans.  changes noted delta 2.  changes include relocation of pv disconnect and and addition of (2) power wall disconnects.  this is plan check only.   [[10/10/17 CHANGES TO APPROVED SET. DELTA 1 CHANGES ARE CLOUDED. PLANCHECK ONLY. RELOCATIING DISCONNECT]]]Plan check for roof-mounted solar pv system with AC coupled battery backup system.10.4kW ungrounded system. (37) 325W pv modules. (2) 5kW Tesla Powerwalls.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75417	15041-10000-37324	5700 N SEPULVEDA BLVD	91411	4	174B145   295	2243004010	(T)(Q)RAS4-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	05/27/2016 12:00:00 AM		Permit Expired	01/22/2018 12:00:00 AM	ADDRESS	34.17405	-118.46591	FULL PLAN CHECK FOR A NEW MIXED USED  6-STORY, 131-UNIT APARTMENT BUILDING. 17 TYPE UNITS. TOTAL AREA 110617 INDOOR + 6160 SQ FT (OUTDOOR).B#14010-20000-01820(PER MEHDI)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75418	14041-20000-06915	813 N WILCOX AVE	90038	4	141B185   209	5533026058	R3-1	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.08565	-118.3311	pv2 apartment rooftop solar. total system size 22.8kw ac using 2 central inverters. nonstandard plan. connect to 3 phase delta.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75419	14041-10000-35100	939 S FIGUEROA ST	90015	14	129A207   291	5138003008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2014 12:00:00 AM	04/21/2015 12:00:00 AM		Permit Closed	07/18/2018 12:00:00 AM	ADDRESS	34.04538	-118.26389	Power and lighting for temporary kitchen space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75420	14041-10002-16757	9000 W 3RD ST	90048	5	138B169   551	4335014001	(T)(Q)R4-2-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			10/18/2019 12:00:00 AM	02/28/2020 12:00:00 AM		Permit Finaled	10/24/2020 12:00:00 AM	ADDRESS	34.07338	-118.38815	Changes to an approved set of plans. All changes are clouded under delta 10,17, 18, & 20. (Original plan checker Mehdi Zandi).Changes include revising single line diagram, adding one panelboard, new circuits, and revising lighting/power plans to reflect as built.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75421	16041-10000-00244	12027 W VOSE ST #13	91605	2	183B165   110	2321003035	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.03	Electrical	Electrical	Commercial			01/05/2016 12:00:00 AM	01/05/2016 12:00:00 AM		Permit Finaled	02/05/2016 12:00:00 AM	ADDRESS	34.19855	-118.39523	TI TO AN EXISTING COMMERCIAL BUILDING.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 810.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75422	14041-10000-02410	837 N CAHUENGA BLVD STE A	90038	13	141B185    80	5533028019	[Q]MR1-1-SN	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			01/28/2014 12:00:00 AM	01/28/2014 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.08637	-118.32899	Remove HID light fixtures and replace with new fluorescent fixtures in a storage space.  Title 24 plan check for fixture one-to-one replacement.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75423	15041-10000-41358	835 W JEFFERSON BLVD BLDG#7	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	02/12/2016 12:00:00 AM		Permit Finaled	09/06/2017 12:00:00 AM	ADDRESS	34.02411	-118.28451	NEW FA SYSTEM. BUILDING 7	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75424	18041-20000-12732	470 S SAN VICENTE BLVD 2nd Floor	90048	5	135B173   177	5510005038	C2-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			04/09/2018 12:00:00 AM			PC Approved	04/09/2018 12:00:00 AM	ADDRESS	34.06943	-118.37497	TI to (E) commercial office tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75425	10041-20001-12643	13550 W PAXTON ST	91331	7	210B157   162	2535002014		North Valley				1043.20	Electrical	Electrical	Commercial			09/29/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.27276	-118.42714	Delta 3 Plan check for revision to approved plans. Added combiner boxes and changes to layout.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75426	17041-10000-30038	4140 W DUNDEE DR	90027	4	154-5A201  72	5592018023	RS-1	Central	Hollywood	Los Feliz	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Permit Finaled	11/22/2017 12:00:00 AM	ADDRESS	34.11808	-118.28363	PV SYSTEM USING 51 MODULES, MICROINVERTER SYSTEM AND SOLAR LOAD CENTER.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75427	17041-20000-41794	10805 W VANOWEN ST	91605	2	183B173   219	2466018044	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1231.03	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	05/23/2018 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.19413	-118.36608	Plan check for power and energy. Project site is an new 3-story self-storage faciltiy. Total lighting area =  65,784 sq. ft.Note: Building application has been generated under 17010-20000-04536.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75428	17041-20001-16312	10321 N WYSTONE AVE	91326	12	204B121    93	2728019011	RA-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2017 12:00:00 AM			PC Approved	06/07/2017 12:00:00 AM	ADDRESS	34.25797	-118.54709	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on SFD.12.6kW ungrounded system (7.6+5).(40) 320W pv modules. Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75429	15041-20001-29715	12648 N OLAF PL	91344	12	219B129    40	2608029037	RE11-1-H, RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/09/2015 12:00:00 AM			PC Approved	09/15/2015 12:00:00 AM	ADDRESS	34.30079	-118.51782	Expedite fees only.       Installation of new roof mounted solar PV array.  Total system size = 12.5 kWac.  Microinverter system with 50 Enphase M250 arranged in 4 branch  circuits..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75430	17041-10000-31214	13748 W DESMOND ST	91331	7	210B157   200	2616030060	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Finaled	09/14/2017 12:00:00 AM	ADDRESS	34.27336	-118.43224	PC for T24 only for removal of outdoor HID fixtures and replacement with new LED fixtures. Total of 5000sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75431	10041-10002-10823	11000 W VENTURA BLVD	91604	2	162B173   535	2378008001	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1438.00	Electrical	Electrical	Commercial			03/28/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.14028	-118.37038	Revision to approved plans. Changes to the pharmacy area layout, new branch circuits added, and T24 calculation, and service load.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75432	14041-20000-24051	7713 N JUSTIN CT	91304	12	189B093   725	2014032049	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2014 12:00:00 AM	10/29/2014 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	34.21059	-118.63167	PV1Install roof-mounted solar array on SFD, interconnect with MSP. System size: 7kW.(1) SMA America SB7000US-12-240V(21) 327 W PV modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75433	17041-10000-08452	9875 N RINCON AVE	91331	7	201B157   219	2622017011	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.21	Electrical	Electrical	1 or 2 Family Dwelling			03/16/2017 12:00:00 AM	03/16/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.24936	-118.4209	Installation of a PV1 roof mounted solar system, central inverter 5.0 KW, 24 solar modules with optimizer.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75434	15041-10000-31234	711 N COLE AVE 1-84	90038	13	141B185   510	5533034030	R3-1	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Apartment			09/21/2015 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.08393	-118.33015	FULL PC FOR A NEW 4 STORY, 84 UNIT APARTMENT WITH SUBTERRANEAN GARAGE. 2000 AMP SERVICE WITH 20 TYPICAL UNITS.   PC FOR ENERGY AND POWER TOTAL SQ. FT. 60865.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75435	12041-10000-14567	2801 N PELHAM PL	90068	4	154-5A191  55	5580001029	R1-1	Central	Hollywood	Hollywood United	YES	1894.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2012 12:00:00 AM	07/11/2012 12:00:00 AM		Permit Finaled	08/17/2012 12:00:00 AM	ADDRESS	34.11921	-118.31988	PLAN CHECK ROOF MOUNTED 9.8KW PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75436	13041-20000-10177	1800 S AVENUE OF THE STARS #900	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM	06/10/2013 12:00:00 AM		Permit Finaled	09/06/2013 12:00:00 AM	ADDRESS	34.06095	-118.41786	Change to lighting, receptacles, loads to an existing high-rise office building on three floors.  Load is less than 200 amps for work on all three floors per applicant.  Plan Check Only for Energy, with Emergency lighting for the 9th Floor.  Permit fees are under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75437	12041-10000-12980	3625 S GRAND AVE	90007	9	118-5A203 223	5122023027	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			06/05/2012 12:00:00 AM			PC Approved	06/05/2012 12:00:00 AM	ADDRESS	34.01785	-118.2778	Plan check for energy and mergency lighting. Scope of work is 4543 uncoditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75438	06041-10005-23699	330 S CENTRE ST HQ Bldg	90731	15	018B201   821	7455019919	C2-2	Harbor	San Pedro	Central San Pedro	YES	2962.20	Electrical	Electrical	Commercial			11/09/2010 12:00:00 AM	11/16/2010 12:00:00 AM		Permit Finaled	01/26/2011 12:00:00 AM	ADDRESS	33.74055	-118.28332	REVISIONS TO PERMITTED SET OF PLANS- NEW CIRCUITS AND REVISED PANEL/SERVICE CALCULATIONS.Revision to approved set of plan. Just panel P1HA is serise rated with upstream EDB BRKR. all others are fully rated.  ( 11-9-10 CHANGES MADE TO FEEDER LENTHS , VOLTAGE DROPS AND FAULT CALCS AS WELL AS SERISE EATINGS.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75439	14041-10000-16694	9547 S COMPTON AVE 1-9	90002	15	093A213   192	6048004031	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			06/20/2014 12:00:00 AM	06/20/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	33.94935	-118.24639	Installation of new fire alarm system in a new 3 story apartment building - 9 units.  Total number of devices = 36	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75440	12041-20000-15484	3900 S BROADWAY PL	90037	9	115-5A203  69	5122043020	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			07/03/2012 12:00:00 AM			PC Approved	07/03/2012 12:00:00 AM	ADDRESS	34.01192	-118.27664	T-24 and emergency lighting plan check.  Electrical permit to be issued on a separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75441	12041-10000-26204	5211 N BASCULE AVE	91364	3	171B109   142	2166028021	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2012 12:00:00 AM	11/01/2012 12:00:00 AM		Permit Finaled	03/26/2013 12:00:00 AM	ADDRESS	34.16492	-118.58639	PV1- STANDARD PLAN PV1 7.2KW SOLAR INSTALLATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75442	18041-10000-03927	811 N CRISTOBAL AVE	90744	15	030B213    43	7425044081	M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	03/28/2018 12:00:00 AM	ADDRESS	33.78172	-118.24299	PC for T24 only for LED replacement existig fixtures with LED fixtures. Total area 7100sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75443	12041-10000-16374	601 W 5TH ST	90071	9	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			07/16/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.05049	-118.25386	REMODEL EXISTING OFFICES  IN SUITE 600  - NEW CIRCUITSPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75444	15041-10001-12882	21221 W OXNARD ST	91367	3	177B105    59	2149005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Apartment			12/14/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.17943	-118.59525	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES TO ORGANIZATION OF DWELLING UNITS ON DISTRIBUTION BOARDS. CHANGE TO INTERIOR, MINOR CHANGES IN CIRCUITRY. ALL CHANGES NOTED DELTA 3,4,AND 5 ON PLANS. OWNER ON RECORD UPDATED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75445	11041-20000-18778	127 S SAN VICENTE BLVD Bulletin-91	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			09/02/2011 12:00:00 AM			PC Approved	09/07/2011 12:00:00 AM	ADDRESS	34.07457	-118.37864	revision bulletin # 91  plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75446	19041-10000-04005	175 S FAIRFAX AVE UNIT E	90036	5	138B177   750	5511026012	C2-1LD-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			02/01/2019 12:00:00 AM			PC Approved	02/01/2019 12:00:00 AM	ADDRESS	34.072	-118.36164	This is plan check only for T24 to (E) express permit under # 18041-10000-28948. Total area: 9830 sq. ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75447	14041-10000-28813	333 S HOPE ST 24TH FLR	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/17/2014 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	PC FOR T4 ENERGY ONLY. TI FOR BANK OF AMERICA.(CONSTRUCT NEW PARTITION TO DIVIDE (E) CONFERENCE INTO TWO OFFICES.) TOTAL AREA 313 SQ FT.B# 14016-10000-21212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75448	19041-10000-19834	2274 E 105TH ST	90002	15	090A217   307	6066020059	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/18/2019 12:00:00 AM	ADDRESS	33.9405	-118.23089	PC FOR ROOFMOUNTED PV ON SFD. SCOPE INCLUDES CENTRAL INVERTER AND 9 MODULES. TOTAL SYSTEM SIZE 3.0KWAC/ 2610KWDC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75449	12041-10000-10058	319 E 2ND ST # 103, 104	90012	14	129A213    10	5161017034	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/02/2012 12:00:00 AM			PC Approved	05/08/2012 12:00:00 AM	ADDRESS	34.04929	-118.24098	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT FOR RETAIL STORES #103 & 104	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75450	18041-10001-41855	212 N ARDEN BLVD	90004	4	138B189   623	5515017008	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM			Reviewed by Supervisor	11/08/2018 12:00:00 AM	ADDRESS	34.07504	-118.32584	EXPEDITE FEE PLAN CHECK FOR ROOFTOP MOUNTED 7.6 PV SYSTEM WITH 2 TESLA POWER WALLS (13.5) KW,  (26) MODULES, WITH  P400 POWER OPTIMIZER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75451	18041-20001-07853	5317 S PACIFIC AVE	90292	11	099A149    10	4294007023	R3-1	West Los Angeles	Venice	Venice		2742.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	33.96719	-118.45629	05-15-2018 Changes to an approved set of plans. Changes include addition of sub-panel between AC Disconnect and MSP. Changes has been clouded. Fees $57.61 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75452	19041-30000-14948	2049 S CENTURY PARK EAST 31st Floor	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.05903	-118.41293	Plan check for Title 24 only. Project site are common area restrooms on the 31st floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75453	16041-10002-23440	20040 W VENTURA BLVD	91364	3	174B113   598	2166043006	C4-1VLD, P-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			10/31/2016 12:00:00 AM			PC Info Complete	10/31/2016 12:00:00 AM	ADDRESS	34.171	-118.56999	10/31/2016 Changes to an approved set of plans. Changes include disaggregation of panels boards for lighing load, HVAC and recptacle load additional of 2 new panelboards. Changes apply to delta 8 only. PC FOR RESTAURANT TI. NEW LIGHITNG WILL BE PC FOR T24 ENERGY ONLY. PERMIT WILL BE ISSUED FOR PANELS AND RECEPTACLES AS REQUIRED BY CONTRACTOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75454	11041-10001-23947	445 N MANSFIELD AVE	90036	5	141B181  1289	5524029022	R1-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2012 12:00:00 AM			PC Approved	01/06/2012 12:00:00 AM	ADDRESS	34.07961	-118.34091	Revision to approved plans: Interactive point of connection relocated to sub-panel from main service panel.(New 12.42KW,Rooftop, Photovoltaic System for a single family residence.   54 pv panels and one inverter with 6 strings of 9 pv panels going to the inverter.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75455	17041-10000-23317	3680 W WILSHIRE BLVD BASEMENT	90010	10	132B193    65	5093006028	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Info Complete	03/06/2018 12:00:00 AM	ADDRESS	34.06149	-118.30603	PLAN CHECK FIR T24 ONLY FOR (TENANT IMPROVEMENT; CHANGE OF USE (E) RESTAURANT TO (N) KARAOKE LOUNGE). TOTAL CONNECTED LAOD <400A - TOTAL AFFECTED AREA - 6373 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75456	19041-20000-36968	5162 W WILSHIRE BLVD	90036	4	132B181    33	5507025018	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			09/16/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Closed	10/22/2019 12:00:00 AM	ADDRESS	34.06202	-118.34232	TENANT IMPROVEMENT FOR AN ANIMAL EXAM ROOM P.C FOR TITLE 24 ONLY.PERMIT FEE PAID UNDER EXPRESS: 18041-30000-08133	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75457	10041-20000-10154	3670 S TROUSDALE PKWY	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			05/28/2010 12:00:00 AM	06/03/2010 12:00:00 AM		Permit Finaled	07/26/2010 12:00:00 AM	ADDRESS	34.01868	-118.28606	Plan check T-24 Energy (general/emergency) lighting for office spaces TI in Bridge Hall (Suite #205 & 300) at USC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75458	12041-10000-25482	3555 E WHITTIER BLVD 1-60	90023	14	121-5A227 207	5188005017	[Q]C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2049.10	Electrical	Electrical	Apartment			10/24/2012 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	02/10/2014 12:00:00 AM	ADDRESS	34.02612	-118.19678	Plan check for new fire alarm system. Apartment. 2 panels and 200 devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75459	19041-10000-48871	384 WORLD WAY SPACE M67	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM			PC Info Complete	12/12/2019 12:00:00 AM	ADDRESS	33.94339	-118.40887	"FIRST TIME TENANT IN SPACE #M67 - COMMERCIAL / RETAIL SPACE IN TERMINAL ""MSC"" IN LAX. INSTALLING PANELS, CIRCUITS & LIGHTS.  PLAN CHECK FOR POWER & ENERGY. AFFECTED AREA: 935 SFT ***M67 - TMZ @ MIDFIELD SATELLITE CONCOURSE (MSC)***BLDG PERMIT: 19016-10000-35475"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75460	18041-20000-34567	9000 N CORBIN AVE	91324	12	195B117    23	2783028047	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/10/2018 12:00:00 AM	11/07/2018 12:00:00 AM		Issued	11/07/2018 12:00:00 AM	ADDRESS	34.23458	-118.56205	permit fee $0.00 by state senate bill no. 1222Plan check for PV roof mounted system for commercial building, system size: 57.6KW AC, 70.2KW DC with  195 PV modules and 4 Solaredge Inverters(14.4kW) connected to 1200A 277/480V Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75461	14041-10002-14159	11600 W WILSHIRE BLVD Unit 199	90025	11	129B145   447	4263013104	[Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM	01/28/2015 12:00:00 AM		Permit Finaled	02/14/2015 12:00:00 AM	ADDRESS	34.05034	-118.45947	Modifications to approved set.  Delta-6 revisions to approved set.  Change of lighting fixtures and corresponding updated Title 24 Part 6 certificate of compliance lighting forms.  (((Renovation of existing commercial tenant space for coffee shop.  Title 24 plan check for changes to lighting system.  Newly connected load under 400A.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75462	18041-30001-03552	355 S MUIRFIELD ROAD	90020	4	135B185   215	5505009007	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM			PC Approved	02/21/2018 12:00:00 AM	ADDRESS	34.06741	-118.32894	Expedite per applicant request	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75463	16041-20000-19703	3711 S LA BREA AVE	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.01909	-118.35577	PLANCHECK FOR POWER AND ENERGY. CHANGE OF USE TO MEDICAL OFFICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75464	15041-20005-39931	11063 W PENDLETON ST	91352	6	198B173    37	2538011020	[Q]M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.02	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Closed	02/12/2020 12:00:00 AM	ADDRESS	34.23911	-118.3725	[[3/20/18 CHANGES TO APPROVED SET. DELTA 8 CHANGES ONLY. ADDITION OF A MOTORIZED GATE]]]]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75465	15041-10000-26492	8521 N FALLBROOK AVE 3RD FLR	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.22368	-118.62797	PC FOR ENERGY ONLY. T-24 FOR A COMMERCIAL BLDG. THE SCOPE OF WORK INCLUDES CORRIDOR AND BATHROOMS IN THE THIRD FLOOR . TOTAL SQ FT : 3494.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75466	19041-20000-37129	4810 N WOODLEY AVE	91436	5	168B141   412	2261022011	RE9-1	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	10/04/2019 12:00:00 AM		Issued	10/04/2019 12:00:00 AM	ADDRESS	34.15776	-118.48346	PV1.  Install 15.04 kW DC / 12.784 kW AC roof mounted grid tied PV system.  (47) modules with microinverters.Fess $40.60 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75467	15041-20001-39444	13722 W FILMORE ST	91331	7	207B157   603	2619028002	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.26426	-118.43165	01/07/2016 Changes to an approved set of plans. Changes have been made to the module count and the inverter.*****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75468	10041-20000-00706	5900 W WILSHIRE BLVD 3rd fl.	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			01/14/2010 12:00:00 AM	01/19/2010 12:00:00 AM		Permit Finaled	02/22/2010 12:00:00 AM	ADDRESS	34.06237	-118.35809	Tenant improvement of restrooms on 3rd floor. Title 24 and emergency lighting only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75469	14041-10002-14892	5826 W OLYMPIC BLVD	90019	4	132B177   757	5085003031	R3-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Apartment			03/06/2015 12:00:00 AM	03/06/2015 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.05724	-118.35691	Modifications to approved set.  (2) additional methane gas sensors added to system to accommodate architectural changes.  (((NEW METHANE SYSTEM FOR 4 UNIT TOWN HOME. 15 DEVICES AND 1 PANEL)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75470	15041-10001-09464	1412 N GLENDALE BLVD	90026	13	141A209   335	5419020017	C2-1L, [Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.20	Electrical	Electrical	Commercial			09/10/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Finaled	10/26/2015 12:00:00 AM	ADDRESS	34.08004	-118.25986	Changes to approved set. Note changes in delta 2. Scope: change of fixtures, relocation of equipment and new ckts. (((PC FOR ENERGY, T24. TI, CHANGE OF USE FROM RETAIL TO BAR/CAFE. TOTAL AREA 1901 SQ FT.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75471	17041-10003-31743	6569 W DE LONGPRE AVE	90028	13	147A187   258	5547026041	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.09624	-118.33278	[[[6/8/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. DELTA 3 CHANGES TO RELOCATE INVERTER AND LOAD CENTERS.]]]permitted set of plans are revised to include fused disconnects for energy storage systems and non fused disconnect for inverter output circuit.(((((((((((((** NO FINAL FEES DUE TO SENATE BILL 1222PC FOR NEW PV SYSTEM WITH BATTERY STORAGE. SYSTEM INCLUDES 28 MODULES, CENTRAL INVERTER AND 2 BATTERY UNITS RATED 5.8KW EACH. TOTAL OF 27KWH OF STORAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75472	16041-10000-39025	1422 W MIRAMAR ST	90026	13	133-5A207 237	5153028022	CW	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Apartment			11/03/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.05956	-118.2617	PC FOR A NEW FIRE ALARM SYSTEM FOR AN APARTMENT BUILDING. SCOPE INCLUDES 66 FA DEVICES, AND 4 FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75473	18041-10000-02085	7436 N HAYVENHURST AVE	91406	6	186B137    31	2226001908	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			01/18/2018 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.20565	-118.49419	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75474	19041-20000-10317	20738 W BEECH CIR #307	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.29343	-118.58555	INSTALLATION OF A 3.02KW DC/2.88KW AC ROOFTOP PV SYSTEM FOR EXISTING SFD. SCOPE OF WORK INCLUDES (9) SUNPOWER 335 BLK PV MODULES WITH INTEGRATED MICROINVERTERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75475	17041-20001-43716	3828 W TRACY ST	90027	4	150B201   888	5433020010	R1-1	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	34.10623	-118.2761	Expedited plan check fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75476	16041-10000-00717	15337 W KINGSBURY ST	91345	7	207B145   395	2649011028	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2016 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	02/17/2016 12:00:00 AM	ADDRESS	34.26342	-118.46633	PV1 roof mounted solar system installation to a single family home. inverter rating: 5.0 kw, (22) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75477	15041-30000-41269	6310 W SAN VICENTE BLVD Suite 107	90048	5	132B173   164	5088018024	C2-1-O-HPOZ	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.06084	-118.36757	Title 24 plan check only.  Total area = 4,245 sq. ft.    T.I. to create gym area in part of first floor of existing commercial low rise building.  New lighting, receptacles, and HVAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75478	10041-10000-00145	9200 N GLENOAKS BLVD	91352	2	198B173   111	2408001003	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley	YES	1211.00	Electrical	Electrical	Public Safety Only			01/05/2010 12:00:00 AM	01/05/2010 12:00:00 AM		Permit Expired	07/19/2012 12:00:00 AM	ADDRESS	34.2363	-118.37296	fire alarm system for office building 1 and 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75479	13041-10002-35406	6904 N VANTAGE AVE # 127	91605	2	183B165   722	2321010***	(T)(Q)RD3-1, R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	02/13/2014 12:00:00 AM		Permit Finaled	02/28/2014 12:00:00 AM	ADDRESS	34.19578	-118.39751	changes to approved set: increased size of inverter. FRONIUS IG 4000 NEG. original description: PV1, Install 2.5 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformered inverter: FRONIUS IG 3000 NEG. (10) modules Trina Solar TSM-250PA05.18.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75480	13041-10000-35856	540 S COMMONWEALTH AVE	90020	13	135A201   133	5077005027	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			12/24/2013 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	01/18/2018 12:00:00 AM	ADDRESS	34.06395	-118.28551	PLAN CHECK FOR POWER AND ENERGY TO A NEW CONSTRUCTION,  FIRST CONGREGATION CHURCH. METHANE ZONE PER ZIMAS. PROJECTED AREA IN LIGHTING SCOPE OF WORK IS APPROX. 75,388 SQ FT. NEW 400A, 480Y/277V, 3PH, 4W SWITCHBOARD 'MSB'. LIGHTING MOSTLY CONSIST OF 277V LIGHTING CKTS.plan check extensions have been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75481	11041-20000-14199	5600 N VAN NUYS BLVD	91401	2	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			07/08/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Closed	10/30/2012 12:00:00 AM	ADDRESS	34.17244	-118.44837	Ti in an existing retail store. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75482	18041-10001-27074	822 S PLYMOUTH BLVD 1-4	90005	4	132B189   424	5090028007	[Q]R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			11/21/2018 12:00:00 AM			PC Approved	11/21/2018 12:00:00 AM	ADDRESS	34.05909	-118.32404	CHANGES TO AN APPROVED SET. DELTA 7 CHANGES INCLUDES THE NOTATION OF THE SERVICE CONDUCTOR SIZE FROM dwp POLE TO THE SERVICE SWITCHBOARD. REVISED WORK DISCRIPTION OF THE MASTER APPLICATION: THE SERVICE SIZE VERIFIED TO BE 600A 120/240 3PH.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75483	15041-10000-14924	9511 N HATILLO AVE	91311	12	198B113    32	2761029009	RS-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.24322	-118.56617	PV1, INSTALL 7.1 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME. (22) MODULES: SUNPOWER SPR327NE-WHT-D (1) INVERTER: ABB-PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75484	18041-10000-38388	9309 N DEERING AVE	91311	12	198B105    88	2746010023	QMR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	10/31/2018 12:00:00 AM	ADDRESS	34.23991	-118.59622	Remove outdoor HID fixtures and replace with new LED fixtures - T-24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75485	12041-20000-28680	14069 N BALBOA BLVD	91342	7	228B137    59	2603006031	[T][Q]M1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	Commercial			11/29/2012 12:00:00 AM	01/14/2013 12:00:00 AM		Permit Finaled	03/07/2013 12:00:00 AM	ADDRESS	34.3209	-118.48756	Plan check for power (title 24 will be paid for later and will be a correction). Installation of 10 electrified truck chargers, related changes to electrical equipment, and  outdoor lighting. Frito Lay.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75486	14041-10000-14671	2053 W VENICE BLVD	90006	10	126B193   221	5075013019	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2212.10	Electrical	Electrical	Commercial			06/03/2014 12:00:00 AM	07/07/2014 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.04374	-118.30174	PC FOR POWER. ONE STORY FUTURE RETAIL STORE. UPGRADE SERVICE TO 800 AMPS. PANELS ARE FOR FUTURE TOTAL LOAD IS BASED 48200 A =800 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75487	12041-10000-04241	8936 S SEPULVEDA BLVD	90045	11	096B165  1080	4123001027	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM			PC Approved	02/27/2012 12:00:00 AM	ADDRESS	33.95499	-118.39596	TI IN AN EXISTING OFFICE AREA. 2 story only first floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75488	18041-10000-04838	13548 W VENTURA BLVD	91423	4	165B157   746	2373011004	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	02/08/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.14744	-118.42876	NEW FIRE ALARM PANEL WITH (14) FIRE ALARM DEVICES IN A CLASSROOM. 10 FIRE ALARM DEVICES WERE WERE PULLED UNDER EXPRESS PERMIT 18041-10000-04815 / X18LA02357.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75489	17041-10000-33329	3125 S LA CIENEGA BLVD	90016	10	123B173  1581	4205035014	MR1-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Commercial			09/18/2017 12:00:00 AM	09/18/2017 12:00:00 AM		Permit Finaled	09/25/2017 12:00:00 AM	ADDRESS	34.02985	-118.37256	PC FOR LIGHTING UPGRADES TO EXISTING OFFICE SPACE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75490	14041-10000-15770	910 S FAIRFAX AVE	90036	4	132B177   328	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.05978	-118.36284	PC for installation of methane mitigation system. high school.[[ INSPECTOR TO VERIFY THE AMPS ( battery calcs based 0.314 amps for sec 3120 transmitter as dual(2)  sensor.)]]]   25 dual sensor devices, one panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75491	18041-20002-36424	20436 W ESMERELDA LANE	91326	12	216B109   208	2701082009	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.29091	-118.57931	SUPPLEMENTAL PLAN CHECK ONLY, CHANGES TO APPROVED SET, CLOUDED CHANGES ONLY. CHANGE FROM PARTIAL TO FULL HOUSE BACK UP. ADDITION OF A FUSE DISCONNECT, MINOR CHANGES TO SINGLE LINE AND SERVICE EQUIPMENT LAYOUT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75492	16041-20000-13470	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			04/18/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Closed	12/08/2017 12:00:00 AM	ADDRESS	34.01318	-118.34004	Plan check for power only. Project scope is temporary power for a medical campus construction. This is Phase 2 of the temporary power installation. Phase 1 can be found under 16041-20000-13454.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75493	14041-20001-28480	20800 W DEARBORN ST	91311	12	198B109   153	2748037018	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.23712	-118.58631	Change to approve set of plan. Add 3 transformer (100KVA and 75KVA) at 277/480V 3Phase(((((SERVICE UPGRADE 1600AMP TO EXISTING COMMERCIAL BUILDING.  ADDING EMPTY PANELS FOR FUTURE TENANTS. PLAN CHECK FOR POWER ONLY.)))))  service was permitted and approved inspector requested some load to enegize the service no load added no additional work	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75494	10041-10000-17698	237 N PARK PASEO	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			09/09/2010 12:00:00 AM			Corrections Issued	09/19/2010 12:00:00 AM	ADDRESS	34.04974	-118.22713	Solar voltaic system installed on the roof of the building.  Consists of  6 modules,  6 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75495	11041-10000-13651	100 S BARRINGTON PL	90049	11	135B145   801	4365006027	RE11-1	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM	07/15/2011 12:00:00 AM		Permit Finaled	08/29/2011 12:00:00 AM	ADDRESS	34.06664	-118.46903	TI IN AN EXISTING SCHOOL.  INSTALLING NEW PANELS, LOADS & LIGHTING. EPC FOR POWER & ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75496	18041-30000-28069	11620 W WILSHIRE BLVD 580	90025	11	129B145   476	4263013103	P-1, QPB-2, [Q]C2-2-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM			PC Info Complete	07/26/2018 12:00:00 AM	ADDRESS	34.05021	-118.45963	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 1842 SQFT. SUITE 580BUILDING PERMIT # 18016-10000-14415	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75497	18041-10000-39517	12736 W COHASSET ST	91605	2	186B161   436	2305026024	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Issued	10/16/2018 12:00:00 AM	ADDRESS	34.2071	-118.41084	NEW ROOF MOUNTED 4.75KW PV SYSTEM WITH 15 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75498	17041-20000-12522	5954 N SIMPSON AVE	91607	2	177B169   852	2339001032	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.02	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	06/09/2017 12:00:00 AM	ADDRESS	34.17914	-118.38873	0$ permit fees due to senate bill 1222pv1install roof mounted pv system sized 16kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75499	19041-20001-05366	9937 N SHOUP AVE	91311	12	201B101    43	2745010033	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2019 12:00:00 AM			PC Approved	02/26/2019 12:00:00 AM	ADDRESS	34.25106	-118.61506	EXPEDITED PER CUSTOMER REQUESTPV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 39 MODULES (SUNPOWER SPR-X22-370D-ACMODULE) AND 39 MICROINVERTERS (SUNPOWER SPR-X22-370-D-AC). SYSTEM SIZE IS 12.4KWAC and 14.43KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75500	14041-10000-16305	2902-2906 N KNOX AVE	90039	13	148-5A213  63	5442017002	M2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	12/18/2014 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	34.10289	-118.24344	PLAN CHECK FOR POWER AND ENERGY. CONSTRUCTION OF 7,500 SQ.FT. 2-STORY TYPE V (B) PRIVATE OFFICE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75501	16041-10002-36823	6041 W CADILLAC AVE	90034	10	126B173  3011	5066002029	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Commercial			02/02/2018 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	02/16/2018 12:00:00 AM	ADDRESS	34.03806	-118.37594	Supplemental for addition of two sump pumps and rewiring of 8 circuits.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75502	14041-10000-04952	738 W 20TH ST	90731	15	012B197  1073	7462016024	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2972.01	Electrical	Electrical	1 or 2 Family Dwelling			02/24/2014 12:00:00 AM	04/02/2014 12:00:00 AM		Permit Expired	04/27/2016 12:00:00 AM	ADDRESS	33.72619	-118.29326	PV1, INSTALL 5.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMER INVERTER: SOLAREDGE SE5000A-US-ZB-U(23) MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75503	17041-10000-19757	814 S BROADWAY	90014	14	127-5A209 160	5144016064	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Issued	07/07/2017 12:00:00 AM	ADDRESS	34.04325	-118.25495	RETAIL TI. PC FOR T24 ENERGY ONLY. LIGHTING AND OTHER UPGRADES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75504	19041-10001-16508	5411 N ETIWANDA AVE 3RD FLOOR	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			11/04/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Permit Closed	04/02/2020 12:00:00 AM	ADDRESS	34.16935	-118.53104	PC FOR CHANGES TO APPROVED SET, SCOPE OF WORK INCLUDED REVISING LIGHTING LAYOUT, T24 FORMS HAVE BEEN UPDATED. ALL CHANGES ARE CLOUDED UNDER DELTA 4 AND DELTA 5.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75505	17041-20000-25273	515 S FIGUEROA ST ste 750	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/26/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75506	10041-10000-23770	14930 W KESWICK ST	91405	6	186B149    15	2209038043	[T][Q]CM-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Public Safety Only			11/30/2010 12:00:00 AM	11/30/2010 12:00:00 AM		Permit Closed	03/15/2011 12:00:00 AM	ADDRESS	34.21004	-118.45845	INSTALLATION OF A FIRE WARNING SYSTEM TO PROVIDE CENTRAL STATION MONITORING OF SPRINKLER AND HVAC SYSTEMS IN A COMMERCIAL BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75507	19041-10000-34420	800 W 6TH ST 14TH	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	TI ON THE 14TH FLOOR.  INSTALLING NEW LIGHT IN THE RESTROOMS AND ELEVATOR LOBBY. T-24 ENERGY ONLY. AFFECTED AREA: 962 SQR FT. BULDING PERMIT: 19016-10000-20225	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75508	17041-20000-31416	7104 N JUMILLA AVE	91306	3	183B117   253	2135017034	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			09/01/2017 12:00:00 AM	09/01/2017 12:00:00 AM		Permit Finaled	09/23/2017 12:00:00 AM	ADDRESS	34.19925	-118.56324	PV1.  Install 9.44 kW roof mounted grid tied PV system.  (32) modules with microinverters.  Microinverter/ACM standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75509	15041-20002-04941	2800 W OLYMPIC BLVD	90006	10	129B197   235	5078013028	C2-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Apartment			01/03/2017 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.05242	-118.2951	(1/2/2017)changes to an approved set of plans.  changing unit feeders and main circuit breakers for unit panels (70).  this is plan check only.  changes noted delta 2.((Plan check for power and energy for new mixed-use apartment building with 4 stories apartment dwelling units. 69 unit apartment with 2500A-rated 208Y/120 service.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75510	18041-30000-29651	601 S FIGUEROA ST STE 2700	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/07/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Issued	08/29/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLAN CHECK FOR T24 ONLY ON (E) 8260 SF  OF COMMERCIAL TENANT IMPROVEMENT. NEW LIGHTING AND POWER REUSING EXISTING PANELS.(B# 18016-10000-24582)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75511	18041-20001-28095	3925 N FIGUEROA ST	90065	1	145-5A223 295	5451009002	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	Arroyo Seco		1994.00	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM			PC Approved	08/14/2018 12:00:00 AM	ADDRESS	34.09188	-118.21087	expeditepv2install roof mounted pv system sized 7.6KW AC interconnected with msp.(16) s energy modules 355W(16) optimizers 400	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75512	11041-20000-09013	16255 W VENTURA BLVD #1250	91436	5	168B137   360	2260010010	C4-1L, PB-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			05/04/2011 12:00:00 AM	05/04/2011 12:00:00 AM		Permit Finaled	06/22/2011 12:00:00 AM	ADDRESS	34.15711	-118.48768	energy plan check # 1250	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75513	16041-10001-38594	4371 N EAGLE ROCK BLVD	90041	14	157-5A219 375	5473026013	[Q]C2-1VL-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1862.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM			Reviewed by Supervisor	11/08/2016 12:00:00 AM	ADDRESS	34.12399	-118.22146	Expedite fees only.            Installation of new roof mounted solar PV array on existing church building.  Total system size = 10.5 kWac.  21 APS YC500i microinverters on three branch circuits connected to 60 amp load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75514	17041-10000-13406	10250 W SANTA MONICA BLVD #1920,1925-, 1930	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Tenant improvement at retail space-Joie - at Century City Mall -  FULL PLAN CHK, tenant space are 1920,1925,1930. Panels fed from DB ELA43	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75515	11041-10002-07146	1605 W CARSON ST	90501	15	051B193   911	7349033034	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	Commercial			07/18/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	08/10/2011 12:00:00 AM	ADDRESS	33.83165	-118.30675	Remodel interior store at existing gas station.  T-24 and electrical plan check.  Inspector please verify existing exterior lighting, and service drop conductors.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75516	17041-10000-14489	11114 N BALBOA BLVD	91344	12	210B133   327	2682021032	C4-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			05/02/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.27268	-118.50197	Title 24 plan check.  LED lighting retrofit of existing Trader Joes store.  Total area = 8,500 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75517	17041-10000-45916	23365 W MULHOLLAND DR	91364	3	168B093    63	2074001042	C1-1VL, C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	Commercial			12/21/2017 12:00:00 AM			PC Approved	12/21/2017 12:00:00 AM	ADDRESS	34.1584	-118.63422	CHANGE OF USE FROM A RETAIL STORE TO A RESTAURANTPLAN CHECK IS FOR TITLE 24ELECTRICAL PERMIT WAS OBTAINED ON 17041-90000-43389THIS IS PLAN CHECK ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75518	13041-10001-35598	11985 W BLUFF CREEK DR BLDG #3	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/28/2014 12:00:00 AM			PC Approved	10/28/2014 12:00:00 AM	ADDRESS	33.98221	-118.40251	Changes to approved set; Instead of overhead severice, applicant changes it to underground. There are also minor changes to title 24. Note per F.Y.(((CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  35,665 SF WITH NEW SURFACE PARKING LOT. 3 TOTAL BUILDINGS.  THIS IS BUILDING 3/5 IN THE SAME PARCEL. TITLE 24 ENERGY FEE CHARGED UNDER THIS BUILDING. METHANE ZONE. BDLG PERMIT: 13110-10000-04243)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75519	14041-20001-35053	10370 N PATRICK AVE	91331	6	204B153    84	2617019020	R1-1-O	North Valley	Arleta - Pacoima	Arleta		1192.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2014 12:00:00 AM			PC Approved	02/02/2015 12:00:00 AM	ADDRESS	34.25931	-118.44055	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). Ungrounded system.26  327W pv modules across 4 strings (inv1 has 9+4; inv2 has 8+5).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75520	14041-20000-07914	1121 N AVALON BLVD	90744	15	033B205   754	7420021021	[Q]C2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2945.20	Electrical	Electrical	Commercial			03/25/2014 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	33.78539	-118.26305	NEW FIRE ALARM SYSTEM FOR YMCA 69 DEVICE AND 1 FIRE ALARM CONTROL PANEL AND 1 COMMUNICATION PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75521	13041-10000-21019	5890 W JEFFERSON BLVD SPACE B	90016	10	120B173   380	4205027011	MR1-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			08/06/2013 12:00:00 AM			Corrections Issued	08/06/2013 12:00:00 AM	ADDRESS	34.02226	-118.3768	PER M.Z., ORIGINAL PLAN WAS LOST AND TO BE HONORED AS ORIGINAL.  ORIGINAL PERMIT NO. 12041-10000-1559208/06/2013((((CHANGE OF USE FROM OFFICE (770 SQ FT) TO TAKE-OUT RESTAURANT, NO SEATING.  Load is less than 200A and occupancy load is 8, per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75522	15041-20000-18865	10100 W SANTA MONICA BLVD 7th & 8th-Floor	90067	5	132B161     9	4319002057	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/17/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.06191	-118.41691	Plan check for Title 24 only. Project site is the 7th and 8th floor of an existing high-rise commercial building. Project scope is a tenant improvement. Total indoor lighting area = 15,748 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75523	12041-20000-05076	11833 W ALLASEBA DR	90066	11	117B153   348	4250002002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2012 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Finaled	05/15/2014 12:00:00 AM	ADDRESS	34.01843	-118.43803	2.12 Kw Microinverter PV System	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75524	19041-10000-24759	7701 N HASKELL AVE	91406	6	189B141   272	2206011051	(Q)CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.21059	-118.47511	Plan check for removing HID fixtures and replace with new LED Fixture for indoor area with a total lighting fixture of 21100-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75525	15041-10001-04083	10630 N SEPULVEDA BLVD	91345	7	207B145   393	2649011021	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			07/20/2015 12:00:00 AM			PC Approved	07/20/2015 12:00:00 AM	ADDRESS	34.26357	-118.46694	ADDITION OF X-RAY MACHINE AND SMALL AC UNIT- DELTA 1 CHANGES((((((((CHANGE OF USE FROM DAY CARE TO MEDICAL OFFICE; ADDED LOAD IS LESS THAN 400A; NEW LOAD IS NEW CIRCUITS FOR LIGHTING AND POWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75526	14041-20000-17535	7070 W SUNSET BLVD	90028	4	147B181   701	5548017038	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			06/27/2014 12:00:00 AM	10/08/2014 12:00:00 AM		Permit Finaled	06/03/2015 12:00:00 AM	ADDRESS	34.0978	-118.34374	PLAN CHECK FOR ENERGY AND POWER.  RESTAURANT CONVERSION TO RESTAURANT WITH NEW EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75527	19041-20000-25262	6225 N CORBIN AVE	91356	3	177B117   332	2153022004	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2019 12:00:00 AM	07/01/2019 12:00:00 AM		Permit Finaled	07/30/2019 12:00:00 AM	ADDRESS	34.18332	-118.56246	INSTALL (1) TESLA POWERWALL 5KW WALLMOUNTED SYSTEM ON EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75528	15041-10001-43181	825 W STATLER ST	90731	15	024B197    66	7442003023	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2016 12:00:00 AM			PC Approved	02/08/2016 12:00:00 AM	ADDRESS	33.76395	-118.29708	**Revision to approved set: Removed 2 modules. Fees zero dollar per CA State Bill 1222.Permit under 15041-10000-43181PV1, ROOF MOUNTED SYSTEM WITH CENTRAL INVERTERS. (39) MODULES (2)  INVERTERS, 5KW  AND A 3KW-AC. TOTAL SIZE IS 8KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75529	13041-20000-01021	300 S GRAND AVE 38th floor	90013	14	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/15/2013 12:00:00 AM			PC Approved	01/15/2013 12:00:00 AM	PIN	34.05243427	-118.25124731	Plan check for energy and emergency lighting. 38th floor. 2040sqft. Corridor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75530	19041-10000-16179	6075 W AVION DR	90045	11	090B169    31	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/01/2019 12:00:00 AM	07/11/2019 12:00:00 AM		Permit Finaled	04/05/2022 12:00:00 AM	ADDRESS	33.94479	-118.38915	Power plan check for a 1200 feet run of reconnecting an existing load at 5KV.  LAX PROJECT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75531	18041-20000-24233	21300 W HART ST	91303	3	183B105   690	2138016015	MR1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	05/25/2022 12:00:00 AM	ADDRESS	34.19728	-118.59574	PV2.  Install 20 kW roof mounted grid-tied PV system. (68) modules with (2) 10kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75532	14041-20001-21041	532 S IRVING BLVD	90020	4	135B189   768	5504010003	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM			PC Approved	10/07/2014 12:00:00 AM	ADDRESS	34.0642	-118.31833	Revisions to approved set.  Inclusion of service load calculations for derating of main breaker.  FEE IS $0.00 DUE TO 2012 STATE SENATE BILL 1222.(((New roof mounted PV system with Enphase model M250-60-2LL.  Total system 14KW.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75533	16041-30000-21790	145 S FAIRFAX AVE 2nd-3rd	90036	5	138B177   683	5511025071	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	02/17/2017 12:00:00 AM	ADDRESS	34.07288	-118.36166	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement to the 2nd and 3rd floors. Total lighting area = 22,571 sq. ft.Note: Building application has been created under 16016-30000-14276	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75534	17041-10000-33697	4010 W 3RD ST	90020	10	135B193   211	5502001009	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2118.03	Electrical	Electrical	Commercial			09/20/2017 12:00:00 AM	09/22/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.06886	-118.30089	PC FOR RESAURANT TI FOR TITLE 24 ENERGY ONLY (TOTAL CONNECTED LOAD LESS THAN 400A)SCOPE INCLUDES NEW PANEL, CIRCUITS AND EQUIPMENT.TOTAL AFFECTED AREA 1180SQ.FT.B# 17016-10000-11487CHANGE OF USE FROM TAKE-OUT RESTAURANT TO RESTAURANT. DISABLED PARKING RESTRIPING ONLY. INTERIOR REMODELING @ KITCHEN & DINING. REPLACE EQUIPMENT, REPAIR FINISHES. NO CHANGE IN NUMBER OF (E) PARKING (ENTERPRISE ZONE) OR OVERALL AREA. NO EXTERIOR WORK.  NO DEMOLITION OF (E) STRUCTURAL WALLS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75535	14041-20000-11344	340 E 2ND ST #200	90012	14	129A215   104	5161020018	[Q]C2-4D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/29/2014 12:00:00 AM	05/02/2014 12:00:00 AM		Permit Finaled	06/27/2014 12:00:00 AM	ADDRESS	34.04836	-118.24075	new lighting. pc for t24 energy only. existing offices. permit for lighting fixtures issued under this application	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75536	19041-20001-51955	11435 N SKYLAND ROAD	91040	7	213B189    39	2551004006	A2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1031.01	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2019 12:00:00 AM			PC Approved	12/23/2019 12:00:00 AM	ADDRESS	34.27732	-118.31558	Revisions to approved plans: change of module layout/array locations.  $0 plan check fee per State Assembly Bill AB 1414. (((Plan check for PV roof mounted system, PV system size: 14.1KW DC 12.44KW AC CEC with 47 PV Modules and 47 Enphase, 2 sub-panels connected to existing 400A Service.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75537	15041-10000-37848	514 E COMMERCIAL ST bus wash	90012	14	130-5A215  66	5173002901	CM-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.05289	-118.23439	ONE-STORY BUS WASHSEE 15010-10000-01118	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75538	15041-20000-07837	1903 N ORCHID AVE	90068	4	150B181   521	5549017018	R2-1XL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2015 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.10501	-118.34037	Plan check for service upgrade. two existing services demo and existing feeder reconnected to new single service.(service combined forn 2 to 1 service)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75539	14041-10000-29306	1722 W SUNSET BLVD	90026	13	139-5A209 130	5404017022	[Q]C2-1L-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			10/22/2014 12:00:00 AM	10/22/2014 12:00:00 AM		Permit Finaled	12/03/2014 12:00:00 AM	ADDRESS	34.07735	-118.25921	this is a one story existing building,  title 24  and exit sign.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75540	18041-10000-05369	6100 W CENTER DR	90045	11	102B169    24	4104001078	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			02/13/2018 12:00:00 AM	04/27/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	33.97733	-118.3922	PC FOR TI-24 ENERGY ONLY. FOR OFFICE TI AND OUTDOOR LIGHTS IN CAMPUS STYLE. TOTAL AFFECTED AREA 23200 SQFT + 3000 SQ.FT (OUTDOOR AND INDOOR)SCOPE INCLUDES NEW LIGHTS, CIRCUITS AND RECEPTACLES.B# 17016-10000-36288	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75541	16041-10000-19967	5744 S BRYNHURST AVE	90043	8	108B185   821	5006003016	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2016 12:00:00 AM	01/27/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	33.98954	-118.33317	PC FOR POWER ONLY. SCOPE INCLUDES INSTALLING A BATTERY BACK-UP INVERTER/ CHARGER, AND A NEW BATTERY BANK INTEGRATED TO AN EXISTING PV SYSTEM.(1)INVERTER/CHARGER-SMA AMERICA SUNNY ISLAND 6048-US NOTE: SOLAR PV SYSTEM PERMIT IS UNDER PCIS#16041-90000-12402	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75542	15041-20000-21423	5101 S WESTERN AVE	90062	8	111B193  1311	5005028014	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	09/15/2015 12:00:00 AM	ADDRESS	33.99677	-118.30908	Plan check for a Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,121 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75543	11041-20000-01730	14718 W RAYMER ST Unit A	91405	6	189B149   540	2210025044	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM	01/28/2011 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.21227	-118.45364	T.I. to existing office space.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75544	18041-20000-26593	21700 W OXNARD ST Suite 950	91367	3	177B105    82	2146006047	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Apartment			07/17/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.17901	-118.60179	Plan check for Title 24 only. Project site is an existing suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 4,471 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75545	19041-20000-35367	5931 N RESEDA BLVD	91356	3	177B125   999	2156025023	R3-1	South Valley	Encino - Tarzana	Tarzana		1393.02	Electrical	Electrical	Apartment			09/06/2019 12:00:00 AM			Reviewed by Supervisor	09/19/2019 12:00:00 AM	ADDRESS	34.17832	-118.53621	PV2. Plan check for PV roof mounted system multi-family building, PV system size: 20.25KW with 50 PV Modules and 2 inverters (7.6KW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75546	18041-10000-21821	2601 S FIGUEROA ST Bld #7	90007	9	121-5A203  23	5123017007	P-1-O, [Q]C2-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	12/24/2019 12:00:00 AM	ADDRESS	34.02804	-118.2763	Fire plan check for an eixising fire alarm system located at the buildig #7 of the same lot of a  multi building structure. All fire alarm system located  in the lot shall interconnced through a same fire alarm system.Total 4 applications under 1 plan including building 1, 4,5 and 7.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75547	13041-10000-06942	15824 W LOS ALIMOS ST	91344	12	207B141   316	2667017020	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1093.00	Electrical	Electrical	1 or 2 Family Dwelling			03/18/2013 12:00:00 AM	03/18/2013 12:00:00 AM		Permit Finaled	05/21/2013 12:00:00 AM	ADDRESS	34.2654	-118.47715	PV1 FOR 1 STORY SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE: 3.024KW. [MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [SOLAR MODULE: REC 245 PE]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75548	16041-10001-17065	13210 W HARDING ST	91342	7	222B157   494	2525002043	RA-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2016 12:00:00 AM			PC Approved	07/14/2016 12:00:00 AM	ADDRESS	34.30286	-118.42094	PV1, INSTALL NEW 10 KW AC GROUND MOUNTD SOLAR ARRAY IN A SINGLE FAMILY HOUSE.(37) MODULES: CANADIAN SOLAR CS6P-255P(1) INVERTER : SOLAREDGE SE10000A-USthis is plan check only. upsized inverter to 10kw and using 275w modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75549	12041-20000-24107	11334 W MOORPARK ST	91602	2	165B173   382	2366005021	[Q]C2-1XL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	Commercial			10/09/2012 12:00:00 AM			PC Approved	10/11/2012 12:00:00 AM	ADDRESS	34.15018	-118.37817	Plan check for energy and emergency lighting. Girasol Restaurant. 4572 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75550	10041-20000-23091	601 S FIGUEROA ST # 1370	90017	9	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			11/18/2010 12:00:00 AM	01/13/2011 12:00:00 AM		Permit Finaled	03/14/2011 12:00:00 AM	ADDRESS	34.05076	-118.25881	energyb plan check # 1370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75551	11041-20000-14316	2121 S AVENUE OF THE STARS	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			07/11/2011 12:00:00 AM	07/11/2011 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.05554	-118.41342	Ti in the lobby & Bath rooms. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75552	18041-20000-46379	4328 N VALLEY MEADOW ROAD	91436	5	165B141   240	2285003037	R1-1	South Valley	Encino - Tarzana	Encino	Yes	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			12/06/2018 12:00:00 AM	12/21/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.14979	-118.47615	Plan check for a PV1 roof-mounted PV system. System size is 24.48 kWdc/17.6 kWac and consists of (2) inverters, (68) modules, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75553	13041-10000-04840	20410 N VIA BOTTECELLI	91326	12	219B109   223	2701059005	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Expired	04/30/2015 12:00:00 AM	PIN	34.29818715	-118.57870679	potovoltaic SYSTEM FOR SINGLE FAMILY DWELLING. 2 STORY DWELLING. SYSTEM SIZE 7.2KW. 2 CENTRAL INVERTERS TRANSFORMED. 30 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75554	13041-10001-36169	1515 W WILSHIRE BLVD	90017	1	132A205   546	5142027034	CW	Central	Westlake	Westlake South		2091.02	Electrical	Electrical	Apartment			02/24/2016 12:00:00 AM	04/14/2016 12:00:00 AM		Permit Finaled	12/27/2016 12:00:00 AM	ADDRESS	34.05498	-118.2688	(  changes made to prviously approvedt addition andrelocation of motor loads.  2-2416  mz    PROPOSED  6 STORY, 218 UNIT MIXED USE RESIDENTIAL BUILDING OVER 1 LEVEL OF SUBTERRANEAN PARKING GARGE and GROUND FLOOR RETAIL , LOBBY AND PARKING BUILDING TO BE FULLY SPRINKLERED PER CBC SEC 903.3.1.1PLAN CHK FEES FOR ENERGY AND FIRE ALARM PLANS VARIANCE IS PENDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75555	19041-10000-14419	2050 S BUNDY DR	90025	11	123B149   419	4259020018	M2-1	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			04/19/2019 12:00:00 AM	04/19/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.03324	-118.45449	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF HID TO LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75556	17041-10002-36915	742 N ORANGE DR	90038	5	141B181   378	5524014004	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM			Corrections Issued	07/05/2018 12:00:00 AM	ADDRESS	34.08467	-118.34147	PC FOR CHANGES TO APPROVED SET.SCOPE INCLUDES REDUCING THREE BREAKERS FROM 150 AMP TO 125 AMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75557	14041-20000-18380	2017 N TAFT AVE	90068	4	151-5A191 376	5587014032	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	08/27/2014 12:00:00 AM	ADDRESS	34.10761	-118.31528	PV1Install roof mounted solar array on SFD. System size: 5kW(1) SMA Sunny Boy 5000TL-US-22 transformerless inverter(21) Hyundai HiS-S260MG(BK) pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75558	14041-20000-12029	12642 W SANDHILL LANE Unit #2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	04/21/2015 12:00:00 AM	ADDRESS	33.97765	-118.41437	Roof mounted PV system with transformerless inverters. System size 1.38KW.  This is part of series set of submittals.  This PV system to interconnect to common service.  This is project 2 of 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75559	19041-10001-46154	22236 W DEL VALLE ST	91364	3	171B101   358	2075003025	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM			PC Approved	12/16/2019 12:00:00 AM	ADDRESS	34.16707	-118.61174	DELTA 1 CHANGES TO APPROVED SET. CHANGES TO THE MODULES' LAYOUT ON THE ROOF. NO CHANGES TO THE SYSTEM SIZE. ORIGINAL SCOPE:PV1, NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. TOTAL SYSTEM SYSTEM SIZE IS 5.13 KWDC / 3.8 KWAC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75560	10041-10001-22200	114 S CENTRAL AVE	90012	14	129A215    84	5161018021	[Q]C2-3D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM			PC Approved	12/27/2010 12:00:00 AM	ADDRESS	34.0487	-118.23901	T-24 lighting plan check only for revised lighting plan for previously approved plans.  Ti in an exixting restaurant. New 400A 3ph 120/240v 3ph service plan chk is for power and title 24. Note that gas seals for conduits to and frm UGPS are required as the site is  in methane zone.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75561	14041-10000-26426	8904 N LANKERSHIM BLVD	91352	6	195B169   231	2631016033	M1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.22	Electrical	Electrical	Commercial			09/24/2014 12:00:00 AM	09/24/2014 12:00:00 AM		Permit Finaled	01/07/2015 12:00:00 AM	ADDRESS	34.23091	-118.38757	Title 24 plan check only. Remove HID light fixtures and replace with new LED fixtures. Total area = 520 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75562	14041-10000-30080	7080 W HOLLYWOOD BLVD	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			10/29/2014 12:00:00 AM			PC Approved	04/24/2015 12:00:00 AM	ADDRESS	34.10134	-118.34445	Plan check for power at request of inspector.  Scope of plan check covers only the installation of two (N) 75 kVA transformers installed to serve (E) subpanels of the tenant space.  Original plan check (energy only) for the TI under 12041-20000-23712.  Permit for the XFMRs and subpanels pulled under 13041-10000-13139.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75563	17041-10000-36915	742 N ORANGE DR	90038	5	141B181   378	5524014004	R1-1	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2017 12:00:00 AM	01/22/2018 12:00:00 AM		Permit Finaled	04/15/2019 12:00:00 AM	ADDRESS	34.08467	-118.34147	PC FOR ESS IN A SFD. SCOPE INCLUDES TWO TESLA POWERWALL 2 NEW LOAD CENTER AND MAIN SERVICE PANEL UPGRADE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75564	17041-30000-24580	3615 S CARDIFF AVE	90034	5	120B165   128	4313017020	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	07/20/2017 12:00:00 AM		Permit Finaled	08/08/2018 12:00:00 AM	ADDRESS	34.02828	-118.39855	Plan check for a fire alarm system for a 2-story apartment building. Fire alarm system consists of (1) FACP, (1) annunciator, and (5) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75565	10041-10000-08498	10101 S BROADWAY	90003	8	091-5A203 192	6053024012	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			05/06/2010 12:00:00 AM	05/19/2010 12:00:00 AM		Permit Finaled	08/09/2010 12:00:00 AM	ADDRESS	33.94445	-118.27854	Install new fire alarm system, 4 cesces panels and 241 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75566	10041-10001-11743	815 W COLORADO BLVD 2nd & 3rd-floors	90041	14	163-5A231 110	5709002013	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	Commercial			06/22/2010 12:00:00 AM	06/22/2010 12:00:00 AM		Permit Finaled	09/07/2010 12:00:00 AM	ADDRESS	34.14051	-118.18382	REVISION TO 10041-10000-1743 INTERIOR TENANT IMPROVEMENTS 2ND & 3RD FLOORS CORRIDORS PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75567	19041-20001-40654	13113 W HARTLAND ST	91605	2	183B161   819	2327007124	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.10	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Approved	11/04/2019 12:00:00 AM	PIN	34.19503918	-118.41865821	10/11/2019PC ONLY, CHANGES TO AN APPROVED SET OF DRAWINGS, CHANGES INCLUDE THE RELOCATION OF MODULES ON THE ROOF. _______________________________________________________________________________PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 10.71 KW DC/8.16KW AC. SCOPE OF WORK CONSISTS OF (34) PV MODULES WITH MICRO INVERTERS AND A 125A COMBINER BOX	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75568	18041-20002-44551	5161 N AMESTOY AVE	91316	5	171B133   350	2258008024	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM			PC Approved	12/20/2018 12:00:00 AM	ADDRESS	34.16454	-118.50558	12-20-2018 Changes to an approved set, module lay out on roof has been re-configured. Changes apply to clouded area only. Plan check only. Fees $0.00 due California Sente Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75569	14041-20000-27321	20945 W DEVONSHIRE ST	91311	12	204B109   145	2706016007	QCR-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.01	Electrical	Electrical	Commercial			10/03/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Finaled	11/24/2014 12:00:00 AM	ADDRESS	34.25741	-118.59007	TI TO AN EXISTING TWO STORIES COMMERCIAL BUILDING.  NEW LIGHTING ADDED TO (2) RESTROOMS USING EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75570	16041-20001-06264	19200 W BALLINGER ST	91324	12	201B117   649	2762011012	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM			PC Approved	04/04/2016 12:00:00 AM	ADDRESS	34.2438	-118.55175	EXPEDITE PER APPLICANT REQUEST.Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 175A.System size: 11kW (5+6). Ungrounded system. (53) 260W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75571	14041-10000-11155	725 S FIGUEROA ST STE# 1000	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	06/26/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.04886	-118.26071	permit to be pulled at EPC counter. plan check for energy only. TI TO 10TH FLOOR STE 1000	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75572	19041-20000-00766	6300 N CANOGA AVE #1300 W	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	01/08/2019 12:00:00 AM		Permit Finaled	04/12/2019 12:00:00 AM	ADDRESS	34.18492	-118.59722	T-24 FOR A TI IN AN OFFICE SPACE IN A HIGH-RISE. SCOPE OF WORK INCLUDES NEW LIGHTING. TOTAL AFFECETD AREA IS 3744 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75573	13041-20000-00602	752 S MAIN ST	90014	14	127-5A211 211	5145001012	[Q]C5-2D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM	ADDRESS	34.04283	-118.2527	Pantry lighting on the 1st, 2nd, 3rd, and 4th floor.  T-24 lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75574	13041-20000-27387	11044 W BURTON ST	91352	6	192B173   697	2314003026	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.22	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	10/02/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.22009	-118.37178	PV1 MICRO INVERTER. TOTAL SYSTEM SIZE 2.15KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75575	16041-10001-23512	1345 N FIGUEROA PL	90744	15	033B201    19	7412009010	[Q]R3-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Harbor City		2943.02	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM			PC Approved	12/12/2016 12:00:00 AM	PIN	33.78947513	-118.2836223	PV2.  CHANGES TO AN APPROVED SET OF PLANS(SOLAR COMMERCIAL). ALL CHANGES ARE MADE UNDER DELTA F. CHANGES INCLUDE REMOVING ONE INVERTER/STRING, REDISTRIBUTING THE NUMBER OF MODULES FOR EACH STRING, REVISING CONDUCTOR AMPACITY CALCULATIONS, CHANGING PANEL CIRCUIT BREAKERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75576	15041-20000-38422	8658 N BALBOA BLVD	91325	12	195B133   474	2689018028	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			11/13/2015 12:00:00 AM	11/13/2015 12:00:00 AM		Permit Finaled	01/15/2016 12:00:00 AM	ADDRESS	34.22803	-118.50241	TI on a cenvenient store in a gas station, all electrical equipment are existing, PC for Energy only. Total area: 190sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75577	17041-20000-11887	1021 S WELLESLEY AVE	90049	11	126B145   149	4264021008	RE9-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2017 12:00:00 AM	04/28/2017 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.0445	-118.4712	0$ permit fees due to senate billl 1222PV1. ROOFMOUNTED SYSTEM. SYSTEM SIZE: 11.83 KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75578	15041-10001-35452	10881 W WILLOW CREST PL	91604	2	162B173   979	2380007021	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2015 12:00:00 AM			PC Approved	12/04/2015 12:00:00 AM	ADDRESS	34.13677	-118.36867	EXPEDITED RSES PLAN CHECK PER APPLLICANT REQUEST.<<<PV1, INSTALL 13.40 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (41) MODULES: SUNPOWER SPR-327-NE-WHT-D(3) INVERTER: POWER-ONE PVI-3.8 & 5000-OUTD-US-A 240>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75579	17041-10000-14232	811 W WILSHIRE BLVD 5TH FLR	90017	14	129A209     9	5144007023	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/01/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	07/24/2017 12:00:00 AM	ADDRESS	34.04973	-118.2584	TI TO 5TH FLOOR OFFICE SPACE. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75580	12041-10000-25557	1344 S ABBOT KINNEY BLVD	90291	11	108B145  1368	4238004037	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.00	Electrical	Electrical	Commercial			10/25/2012 12:00:00 AM	11/13/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	33.99069	-118.46662	TI in an existing restaurant. Indoor and outdoor lighting. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75581	14041-20001-00288	1447 W AVON TER	90026	13	144B213   732	5415008005	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2014 12:00:00 AM			PC Approved	01/22/2014 12:00:00 AM	ADDRESS	34.0894	-118.24564	((EXPEDITE FEES))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75582	17041-20000-10411	749 S KOHLER ST	90021	14	124-5A213 147	5146004050	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM			PC Approved	03/31/2017 12:00:00 AM	ADDRESS	34.03638	-118.24371	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a fire damage repair/tenant improvement. Total lighting area = 7,932 sq. ft.Note: Building application has been generated under 17016-20000-03629	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75583	10041-20001-22630	440 S VERMONT AVE #116, 130	90020	13	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM			PC Info Complete	12/23/2010 12:00:00 AM	ADDRESS	34.0659	-118.29143	Change the priviously approved plan. Addition of a refrigerator and new branch circuits. EPC is for the change.  ((((((((((((((((((((((((PLAN CHECK POWER AND ENERGY FOR FIRST TIME TENANT COFFEE SHOP #116 AND STORAGE #130))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75584	17041-10000-24518	1601 N VINE ST 8th floor	90028	13	148-5A187 301	5546009154	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			07/20/2017 12:00:00 AM	11/06/2017 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.09996	-118.32693	PC for T24 only for office TI of entire 8th floor. PC includes addition of lighting and receptacles. Installing 2 new panelboards, new circuits and equipment. Total area 13217 sqft. Load under 400A. Building#17016-10000-19952.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75585	14041-10000-04542	12455 W WICKS ST	91352	6	192B165    76	2634014903	OS-1XL-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			02/19/2014 12:00:00 AM			Verifications in Progress	02/20/2014 12:00:00 AM	ADDRESS	34.22624	-118.40457	Ti in an existing electrical room, addition of solar light pole for parking. EPC is for indoor/ outdoor T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75586	13041-10000-34134	1801 E 45TH ST BLDG E	90058	9	112-5A213 138	5106005033	M2-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2288.00	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			PC Approved	12/09/2013 12:00:00 AM	ADDRESS	34.00291	-118.24112	PLAN CHECK FOR EMERGENCY LIGHTING AND EXIT SIGNS ONLY PER INSPECTORS REQUEST. 5 OF 5 BUILDINGS. BUILDING E.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75587	10041-10000-09976	6061 W SUNSET BLVD	90028	13	147A189    44	5545008007	C4-1-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Public Safety Only			05/26/2010 12:00:00 AM	05/26/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	34.09819	-118.32082	Install a new Fire Alarm System in the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75588	19041-10000-14709	505 S VERMONT AVE	90020	10	135B197   768	5502024013	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2121.01	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM			PC Approved	04/22/2019 12:00:00 AM	ADDRESS	34.06509	-118.29191	PLAN CHECK FOR POWER IN A HAZARDOUS LOCATION PER INSPECTOR REQUEST. SCOPE INCLUDES CONDUIT UNDERGROUND RUN WITH EYS SEALS FOR 2 VACUME MACHINES AND 1 PAY STATION. Plan Check Only PARKING LIGHT POLES PERMITT IS PULLED UNDER 19041-10000-11703T-24 FOR OUTDOOR LIGHTING PERMITT IS PULLED UNDER 19041-10000-11536	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75589	16041-20000-39275	2558 W SAN FERNANDO ROAD	90065	1	150B213   451	5457002013	[Q]M1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Glassell Park		1871.02	Electrical	Electrical	Commercial			11/04/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	05/04/2017 12:00:00 AM	ADDRESS	34.10789	-118.24149	Plan check for a fire alarm system for an existing commercial building. Fire alarm consists of (1) FACP and (66) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75590	16041-20000-02950	8824 N TYRONE AVE	91402	6	195B149   381	2639005011	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.05	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2016 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	34.23075	-118.44815	Plan check for PV roof mounted system. System size: 5.0kW with 18 modules and 1 inverter(5.0kW). Standard plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75591	16041-10000-00482	3440 W WILSHIRE BLVD STE 3432	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04	Electrical	Electrical	Commercial			01/07/2016 12:00:00 AM	04/18/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.06151	-118.29944	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTUARANT (THE HALAL GUYS). SCOPE INCLUDES NEW LIGHTING AT SUITE 3432. TOTAL AFFECTED AREA IS 1691 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75592	15041-10000-03977	12618 W STANWOOD PL	90066	11	117B149    77	4247002003	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2714.00	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Refund in Progress	05/24/2016 12:00:00 AM	ADDRESS	34.01367	-118.44547	PV1 ROOF MOUNTED RESIDENTAIL PHOTOVOLTAIC. COMBINING 2 OF 3 STRINGS. 26 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75593	14041-10000-05454	5791 W IMPERIAL HWY BLDG A	90045	11	087B169     1	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/27/2014 12:00:00 AM	02/27/2014 12:00:00 AM		Permit Finaled	02/13/2015 12:00:00 AM	ADDRESS	33.93414	-118.3839	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO DHL EXPRESS IN LAX. LIGHTING FOR CANOPY STRUCTURE. 9911 SQFT, EMERGENCY LIGHTING. BUILDING A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75594	16041-10000-12938	755 N LILLIAN WAY	90038	13	141B185   289	5533032025	CM-1VL	Central	Hollywood	Central Hollywood		1918.20	Electrical	Electrical	Commercial			04/14/2016 12:00:00 AM	10/20/2016 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.08511	-118.32786	New 600A service 120/240V 3-phase 4W, on Methane Buffer zone. Change of use from warehouse and garage to music studio. Total area: 4,272 sq.ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75595	17041-30002-17304	11979 W WALNUT LANE 1-4	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			10/23/2018 12:00:00 AM			PC Approved	10/23/2018 12:00:00 AM	ADDRESS	34.03749	-118.4591	Supplemental plan check only (permit shall be covered under master) . Relocating panel P1, still within the same unit. No significant change on Fault current and Voltage drop. ((PLANCHECK FOR POWER AND ENERGY.  4 UNITS APARTMENT WITH 4 STORY OVER SUBTERRANEAN GARAGE.building permit # 15010-10000-02913))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75596	19041-20000-46112	11940 N WOOD RANCH ROAD	91344	12	216B129   224	2601066010	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2019 12:00:00 AM	11/08/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.28801	-118.52203	PV1 PLAN CEHCK FOR 19.6 KW DC/18.9 KW AC PV SYSTEM. SCOPE OF WORK CONSISTS OF (60) PV MODULES WITH MICROINVERTERS, AND A 125A LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75597	18041-20000-25174	7343 N TYRONE AVE	91405	2	186B153   889	2217001161	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2018 12:00:00 AM	07/06/2018 12:00:00 AM		Permit Finaled	10/03/2018 12:00:00 AM	ADDRESS	34.2043	-118.44457	Plan check for PV roof mounted system, System size: 5.2kW with 16 modules  and  1 inverter(5.2kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75598	10041-20000-09341	3916 W SUNSET BLVD	90029	13	145-5A203 391	5427007003	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1959.01	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM			PC Approved	05/18/2010 12:00:00 AM	ADDRESS	34.09192	-118.28012	Doing lighting and power in some portion of a restaurant. P/C is for energy only. Permit already exist in app# 10041-20000-08070.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75599	19041-20000-07628	515 S FIGUEROA ST 780	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	09/27/2019 12:00:00 AM	ADDRESS	34.05199	-118.25764	T24 PLAN CHECK FOR POWER AND LIGHTING FOR EXISTING HIGH RISE COMMERCIAL BUILDING 7TH FLOOR STE 780, CHANGE OF LIGHTS FROM FLOURESCENT TO LED, MINOR RELOCATION OF LIGHTS, NEW LIGHTING CONTROLS, AND NEW OUTLETS. TOTAL SQUARE FOOTAGE = 3319 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75600	17041-20000-29855	3650 W MARTIN LUTHER KING, JR BLVD Suite 176	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			08/22/2017 12:00:00 AM	10/13/2017 12:00:00 AM		Permit Finaled	12/04/2017 12:00:00 AM	ADDRESS	34.01118	-118.33649	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,420 sq. ft.Note: Building application has been generated under 17016-10000-16322	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75601	18041-20000-35926	22647 W DEL VALLE ST	91364	3	171B097   366	2040032021	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1372.01	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM			PC Approved	09/19/2018 12:00:00 AM	ADDRESS	34.16621	-118.61986	Plan check for Title 24 only in existing parking space outdoor lighting. Total area: 7,000 sq ft.Plan check only permit pulled under Applicantion Number#18041-20000-24893	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75602	10041-10000-06090	4852 W MELROSE AVE	90004	4	141B193   594	5521004016	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM	05/17/2011 12:00:00 AM		Permit Finaled	01/14/2013 12:00:00 AM	PIN	34.08337382	-118.3060894	Change of use, real estate office to dental office.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75603	11041-20000-20276	11713 W RIVERSIDE DR	91607	2	168B169   412	2355017019	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM			PC Approved	09/22/2011 12:00:00 AM	ADDRESS	34.1578	-118.3882	Creating new rooms within the existing space.  Light fixtures have not been relocated but have been wired to comply with the switching requirements.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75604	19041-20000-26364	17070 W ENCINO VERDE PL	91436	5	162B133   116	2292010030	A2-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2019 12:00:00 AM	07/12/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.14044	-118.50366	Plan check for a PV1 ground-mounted PV system. System size is 23.1 kWdc/19.64 kWac-CEC and consists of (70) modules, (70) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75605	19041-20000-15115	1837 S MESA ST	90731	15	012B201   784	7456029035		Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2019 12:00:00 AM	04/24/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	33.72717	-118.28593	Plan check for a PV1 roof-mounted PV system. System size is 3.02 kWdc/2.88 kWac and consists of (9) AC PV modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75606	12041-10000-09023	1311 N SAN FERNANDO ROAD BLDG. A	90065	1	150B213  3619	5442002908	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	04/02/2013 12:00:00 AM		Permit Finaled	07/15/2014 12:00:00 AM	ADDRESS	34.09591	-118.23223	Plan check for new 36-unit  apartment bldg.Application for deferred approval of fire alarm system NOT submitted.(Taylor Yard Apartment (Building A) - construct new 36-unit low restricted affordable apartment with parking option II (35 restricted affordable and one manager unit)- 100% PDPP.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75607	13041-10000-04647	414 E BROOKS AVE	90291	11	108B145   563	4239010019	RD1.5-1	West Los Angeles	Venice	Venice		2733.00	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2013 12:00:00 AM	02/25/2013 12:00:00 AM		Permit Finaled	03/28/2013 12:00:00 AM	ADDRESS	33.99394	-118.47132	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.18KW. USING 19 PANELS. TRANSFORMERLESS INVERTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75608	14041-10000-00539	908 E 8TH ST	90021	14	124-5A213 195	5146023036	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/08/2014 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Expired	02/02/2016 12:00:00 AM	ADDRESS	34.03616	-118.24658	FA FOR (E) COMMERCIAL 90 DEVICES AND 1 PANEL AND 1 ANNUNCIATOR AND REMOTE POWER SUPPLY. 2 STORY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75609	17041-10000-13069	104 N AVENUE 56	90042	1	151-5A227 232	5468024010	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	09/05/2017 12:00:00 AM	ADDRESS	34.10918	-118.19452	Installation of new fire alarm system in existing 3 story commercial building.  Total system size = 95 devices + 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75610	19041-20000-37082	11211 N SEPULVEDA BLVD lot #24	91345	7	210B145    27	2664007019	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2019 12:00:00 AM	09/20/2019 12:00:00 AM		Permit Finaled	03/26/2020 12:00:00 AM	ADDRESS	34.27428	-118.46813	PV1. INSTALL 4.09 KW DC ROOF MOUNTED PV SYSTEM WITH (13) MODULES WITH OPTIMIZERS AND (1) INVERTER (SE3800H).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75611	12041-20000-10558	3206 N WASHINGTON BLVD	90291	11	108B149  1266	4237027033		West Los Angeles				2741.00	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM	07/05/2012 12:00:00 AM		Permit Finaled	05/22/2013 12:00:00 AM	PIN	33.9900674	-118.44897566	Change from bank to dental office. Plan check for power and energy. Single story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75612	13041-20001-13571	12059 W VENTURA PL	91604	2	165B165  1242	2368002010	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1436.02	Electrical	Electrical	Commercial			08/29/2013 12:00:00 AM			PC Info Complete	09/10/2013 12:00:00 AM	ADDRESS	34.14469	-118.39458	ignore this application.additions changes have been resubmitted. refer to supplemetla 20002 for most updated changes	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75613	15041-20000-05334	5514 W WILSHIRE BLVD	90036	4	132B181     3	5089004012	[Q]C1.5-2-CDO, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2162.00	Electrical	Electrical	Commercial			02/24/2015 12:00:00 AM	02/24/2015 12:00:00 AM		Permit Expired	03/20/2017 12:00:00 AM	ADDRESS	34.06209	-118.3488	Plan check for Title 24 only. Project is a TI to an existing tenant space. Tenant space is an art gallery. Total lighting area = 3,200 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75614	14041-20000-28347	22441 W HARTLAND ST	91307	12	183B101   703	2024029010	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2014 12:00:00 AM			Corrections Issued	10/21/2014 12:00:00 AM	ADDRESS	34.19474	-118.61627	PV1 SFD. TOTAL SYSTEM SIZE 11.5KW AC USING 2 CENTRAL INVERTERS. NONSTANDARD PLAN.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75615	13041-20000-22720	6537 W 84TH PL	90045	11	096B165   154	4108013008	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM	09/05/2013 12:00:00 AM		Permit Finaled	09/23/2013 12:00:00 AM	ADDRESS	33.96216	-118.40293	pv1 single family dwelling. total system size 3.8 kw using 12 modules. system uses power optimizers. nonstandard plan transformerless inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75616	19041-10000-08613	7708 N GOODLAND AVE	91605	2	189B161  1102	2305032028	R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1216.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Issued	03/11/2019 12:00:00 AM	ADDRESS	34.21072	-118.41229	PV1. NEW ROOFTOP SOLAR SYSTEM  . CONSIST OF 18 MODULES (Q-PEAK 305), OPTIMIZERS SE P320) AND A CENTRAL INVERTER (SE5000H-US). SYSTEM SIZE IS 5.49KWdc AND 5KEac	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75617	18041-10001-20325	6505 S ESPLANADE #1	90293	11	096B149   106	4116005***	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2781.02	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			Reviewed by Supervisor	06/13/2018 12:00:00 AM	ADDRESS	33.96159	-118.45071	1 OF 5******EXPEDITE PER APPLICANT REQUEST	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75618	13041-10003-03123	6501 N FALLBROOK AVE	91307	3	180B097   471	2038040016	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			02/11/2014 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.1881	-118.62368	][]][ CHANGES MADE TO APPROVED SET OF PLANS DUE TO LIGHTING REVISION PER INSPECTOR'S REQUEST ; PLAN CHECK FOR T24 PART 6 ENERGY ONLY ][][]PLAN CHECK FOR POWER AND ENERGY. ELECTRICAL WORK IS FOR NEW OLIVE GARDEN RESTAURANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75619	18041-20001-48782	3984 N TARRYBRAE TER	91356	3	162B117   115	2180004017	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2019 12:00:00 AM			PC Approved	05/16/2019 12:00:00 AM	ADDRESS	34.14229	-118.56067	05-16-2019 Changes to an approved set of plan, changes include remove battery disconnect. Changes has been clouded.Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75620	16041-10001-41815	19404 W PAUMA VALLEY DR	91326	12	213B117   224	2822027009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2017 12:00:00 AM			PC Approved	01/03/2017 12:00:00 AM	ADDRESS	34.28113	-118.55513	01/03/17Changes to an approved set of plans. changes include relocating one solar module from string 1 to string 2, and relocating the module on the roof. Note: Permit is paid under PCIS#16041-10000-41815	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75621	14041-10000-08238	300 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/27/2014 12:00:00 AM			PC Approved	03/27/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	TI to DFS Galleria (change of engineer from 14041-10-04354). T.I. - TENANT BUILD-OUT OF (E) RETAIL SPACE AND STORAGE ROOM AT LAX. ( 740 SQ.FT.). permit to be pulled at EPC counter only. Plan check for energy only. emergency lighting. fees under inspection. 14016-10-05611:DUTY FREE SHOP, INTERIOR TENANT IMPROVEMENT @ LAX; CEILING, SALES SHELVING FIXTURES AND PARTITION; (STOREFRONT AND DEMISING WALLS UNDER SEPARATE PERMIT 13016-10000-20472)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75622	19041-10000-47844	15489 W DUOMO VIA	90077	5	156B145   177	4378036002	RE15-1-H-HCR	South Valley	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	12/05/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	34.124	-118.47064	$0.00 FEE PER AB# 1414 & SB# 1222[EPLAN] LOOK FOR DELTA  E CHANGES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75623	16041-20001-03733	3636 S CAROLINA ST	90731	15	006B197   790	7467015029	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2976.02	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	33.71089	-118.29049	Expedited plan check per applicant request.  PV1.  Permit previously finaled under 15041-90000-38480.  Change of inverter from single phase to three phase type after finaling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75624	18041-20000-33434	20665 W BEECH CIR #322	91326	12	219B109   357	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.29292	-118.58459	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75625	15041-20000-42635	1874 N CURSON AVE	90046	4	150B177   336	5571030022	RE15-1-H	Central	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	02/09/2016 12:00:00 AM	ADDRESS	34.10547	-118.35515	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac. (28) sunpower x21-335-blk (28) solaredge power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75626	19041-10000-32519	1718 W 245TH ST	90717	15	039B193   323	7372014005	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2019 12:00:00 AM	12/02/2019 12:00:00 AM		Permit Expired	10/10/2023 12:00:00 AM	ADDRESS	33.80249	-118.3086	[EPLAN] PV1. PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE) WITH 12 MODULES USING RAPID SHUTDOWN DEVICES AND ESS(TESLA POWER WALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75627	15041-10000-09060	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	05/26/2015 12:00:00 AM		Permit Finaled	07/20/2015 12:00:00 AM	ADDRESS	34.07196	-118.24719	Energy plan check for outdoor site lighting located at the main entrance ( sheet 5,9 &10 on key map of the plan) , gate A.  Total area is 217,060-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75628	16041-10001-08270	633 W 5TH ST 4TH FL	90071	15	015B197   195	7451029032	[Q]R3-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			11/29/2016 12:00:00 AM			PC Info Complete	12/07/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	Plan check for place of assembly Restaruant 415 occupant load. Total area: 10,661 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75629	12041-20001-03104	6201 W HOLLYWOOD BLVD	90028	13	148-5A189  54	5546031001	[T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			09/13/2012 12:00:00 AM	09/21/2012 12:00:00 AM		Permit Closed	10/02/2014 12:00:00 AM	ADDRESS	34.1018	-118.32461	Modification to previously approved plan.  reduced the quantity of equipment.  added one addtional +150 tower crane.  See existing permit for all items paid.  for a temporary 1600A service power for construction site of a new mixed-use building.  Plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75630	15041-20000-00491	2027 N MORGAN HILL DR	90068	4	151-5A191 373	5587014031	R1-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2015 12:00:00 AM	01/09/2015 12:00:00 AM		Permit Finaled	02/06/2015 12:00:00 AM	ADDRESS	34.10776	-118.31414	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 402KW INTERCONNECTED WITH MSP.(19) HYUNDAI HIS-S260 MODULES(1) ABB PVI-4.2OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75631	17041-10000-41424	11203 W NATIONAL BLVD	90064	5	120B157   244	4251002022	C2-1VL	West Los Angeles	West Los Angeles	Westside		2717.02	Electrical	Electrical	Commercial			11/15/2017 12:00:00 AM			PC Approved	12/14/2017 12:00:00 AM	ADDRESS	34.02745	-118.42919	CHANGE OF USE FROM RETAIL TO BEAUTY SALON. EXCEPT FOR THE RESTROOM, LUMINAIRES ARE EXISTING. WALLS ENCLOSED AREA FOR TWO FACIAL ROOMS.PLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75632	16041-20000-00521	13032 N ANGELES TRAIL WAY	91342	7	225B165    19	2580018***	(Q)RD6-1, A1-1, A1-1XL, A1-1XL-K	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2016 12:00:00 AM	01/29/2016 12:00:00 AM		Permit Finaled	02/23/2016 12:00:00 AM	ADDRESS	34.30923	-118.40436	PV1.  Install a roof mounted solar array on a SFD. Interconnect with 200A MSP, derating main to 175A.New 3kW ungrounded inverter using 300W power optimizers. There is an existing solar system on roof rated 4.2kW. System size: 3kW (new) + 4.2kW (existing) = 7.2kW.(11) 265 pv modules, one optimizer each.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75633	13041-10000-33148	10161 N LANGMUIR AVE	91040	7	204B193  1064	2559034044	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1034.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.25399	-118.30881	PV1.  Install 7.5 kW roof-mounted PV system, interconnect with main service panel.  30 modules: Trina Solar TSM-250PA05.18.  Transformed inverter: Fronius IG PLUS V 6.0	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75634	14041-20000-23442	21300 W VICTORY BLVD Ste 830	91367	3	180B105    55	2149001031	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			08/27/2014 12:00:00 AM	08/27/2014 12:00:00 AM		Permit Finaled	11/12/2014 12:00:00 AM	ADDRESS	34.18813	-118.59618	TI to existing commercial high rise office tenant space.  Plan check under 2013 Building Energy Efficiency Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75635	14041-10001-12932	189 S THE GROVE DR	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM			PC Info Complete	05/18/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	CHANGES TO AN APPROVE SET. REVISING THE LIGHTING LAYOUTS IN THE SALES AREAS LV. 1,2, AND 3 AND 4 NEW EXTERIOR LIGHT FIXTURES. ((PLAN CHECK FOR POWER AND ENERGY FOR NIKE STORE AT THE GROVE. EXISTING SERVICE, NEW LOADS AND PANELS.))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75636	17041-20002-00448	9255 N CORBIN AVE	91324	12	198B117   150	2761001075	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM			PC Approved	07/12/2017 12:00:00 AM	ADDRESS	34.23837	-118.56248	[[[[7/12/17 CHANGES TO APPROVED T24 ENERGY. UPDATING SINGLE LINE TO SHOW DISSAGGREGATION OF PANELBOARDS]]]]]01/18/2017 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,042 sq. ft. *****Previous Work Description*****NEW OUTLETS WITH BRANCH CIRCUITS TO PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75637	18041-10001-46787	7101 S MENLO AVE	90044	8	102B197   992	6013001015	RD1.5-1	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			12/10/2018 12:00:00 AM			Reviewed by Supervisor	12/18/2018 12:00:00 AM	ADDRESS	33.97534	-118.28937	Expedite per applicant request(((PV2 21.2 KW AC / 26.6 KW DC roofmounted system with (71) modules, (3) inverters interconnecting through a main service panel.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75638	17041-20000-17009	120 N ROBERTSON BLVD	90048	5	138B169   244	4334002029	[Q]C2-1VL-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/28/2017 12:00:00 AM		Issued	07/28/2017 12:00:00 AM	ADDRESS	34.07585	-118.38356	Plan check for power only. Replace and relocate 1,000kVA transformer in commercial building. Refeed existing distribution.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75639	16041-10000-15448	541 S SPRING ST # 106 &-107	90013	14	129A211   280	5149035***	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/03/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	34.04657	-118.2507	CHANGE OF USE SPACE NOS. 106 AND 107 FROM RETAIL TO RESTAURANT TENANT IMPROVEMENT . PC FOR T-24 ONLY. TOTAL AREA: 2,160 SQ. FT.B# 15014-10000-03512	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75640	12041-10000-08103	6757 N LIMERICK AVE	91306	3	180B109    46	2148003014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Expired	05/06/2014 12:00:00 AM	ADDRESS	34.19347	-118.58309	New 10.75KW roof mounted photovoltaic system for an existing single family dwelling.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75641	17041-20001-30914	949 N EVERETT ST	90026	1	136-5A211 159	5406016015	[Q]R3-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1977.00	Electrical	Electrical	Apartment			05/22/2018 12:00:00 AM			PC Approved	05/22/2018 12:00:00 AM	ADDRESS	34.06892	-118.24921	05/22/2018 Plan check for a PV2 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (16) modules. *****Previous Work Description*****Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75642	18041-20000-21377	5431 W 104TH ST	90045	11	090B173   263	4129033003	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	33.94208	-118.37551	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75643	11041-20000-00523	17777 W VENTURA BLVD # 220A-D	91316	5	171B129   296	2162013004	C4-1VL	South Valley	Encino - Tarzana	Encino		1395.01	Electrical	Electrical	Commercial			01/11/2011 12:00:00 AM	01/11/2011 12:00:00 AM		Permit Finaled	07/15/2011 12:00:00 AM	ADDRESS	34.16303	-118.51993	TI unit # 220 A-D	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75644	16041-20000-37682	5900 W WILSHIRE BLVD ste 2900	90036	4	135B177   547	5086021038	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	11/03/2016 12:00:00 AM		Permit Finaled	01/30/2017 12:00:00 AM	ADDRESS	34.06237	-118.35809	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check foe energy and em lighitng only.  total square footage 5073 in ste 2900.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75645	11041-10000-07447	7566 W MELROSE AVE	90036	5	141B177   651	5526016025	C4-1XL-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	Commercial			04/13/2011 12:00:00 AM			Corrections Issued	04/19/2011 12:00:00 AM	PIN	34.083407	-118.35485229	New 600 Amp service for a core & shell commercial Bldg. EPC is for power & t24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75646	10041-10000-09410	1820 W SLAUSON AVE	90047	8	108B193  1398	6001001024	M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.00	Electrical	Electrical	Commercial			05/19/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	02/18/2011 12:00:00 AM	ADDRESS	33.98794	-118.31101	Ti work for an existing grocery store. lighting , power and title 24. 240 new brach and 3 new panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75647	11041-10000-23048	5757 W WILSHIRE BLVD 1st & 9th-floors	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM	11/02/2011 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.06259	-118.35341	T-24 plan check for lighting in Mens and Womens restroom renovation on 1st and 9th floors. New lighting and receptacles installed on existing circuit.  Emergency lighting also reviewed.  Permit is to add units in bathrooms on multiple floors of the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75648	12041-10000-04166	1055 W 7TH ST 32nd floor	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/24/2012 12:00:00 AM			PC Approved	03/06/2012 12:00:00 AM	ADDRESS	34.0507	-118.26334	TI in 32nd floor of an existing office BLDG. EPC is for T24 & Emergency lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75649	19041-10000-44075	6610 W MARYLAND DR	90048	5	135B173   464	5510015032	R1-1-O-RFA	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	12/20/2019 12:00:00 AM	ADDRESS	34.06758	-118.37128	(E-PLAN) EXISTING ROOF-MOUNTED PV1 TO AN EXISTING SERVICE OF  200 AMPS WITH EXISTING 24 MODULES (LG365N1C-A5), 24 OPTIMIZERS (P400), 1 INVERTER (SE10000H-US). NEW INSTALLATION INCLUDES 1 SUB PANEL OF 200 AMPS, 1 SUBPANEL OF 125 AMPS, AND 2 POWERWALL BATTERIES . SYSTEM SIZE: 8.76 KW DC; 10 KW AC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75650	14041-20000-26706	12000 S VISTA DEL MAR	90293	11	084B157     1	4131029901	PF-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/26/2014 12:00:00 AM	09/26/2014 12:00:00 AM		Permit Finaled	10/03/2016 12:00:00 AM	PIN	33.92817449	-118.43220714	Like-for-like replacement of (1) master control panel and (6) control panels for existing flares at Hyperion Treatment Plant.  Class 1 Div 1 location.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75651	13041-10000-20647	8701 S METTLER ST	90003	9	097-5A207 402	6041018016	M2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			08/02/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/05/2013 12:00:00 AM	ADDRESS	33.95908	-118.26671	TENANT IMPROVEMENT. UPGRADE SERVICE FROM 200AMP TO 800 AMP. ADDING CIRCUITS. NO CHANGES IN LIGHTING. POWER PLAN CHECK ONLY. 1 FLOOR. SERVER ROOM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75652	14041-20000-25702	14006 W RIVERSIDE DR #91	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	11/26/2014 12:00:00 AM		Permit Closed	04/10/2015 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for energy only. TI to existing retail building . New lighting (incl. emergency). 3,600sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75653	16041-20000-20814	10469 N SAN FERNANDO ROAD	91331	7	207B161   433	2620028006	M2-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	34.26046	-118.41643	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING TO EXISTING PANELS.  PLAN CHECK FOR ENERGY ONLY.  TOTAL SQUARE FOOTAGE 3795.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75654	13041-20000-20945	6601 N SHELTONDALE AVE	91307	12	180B089   399	2034016005	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM	08/06/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.1907	-118.6531	PV1 SINGLE FAMILY DWELLING TOTAL SYSTEM SIZE 7.2 KW USING 2 CENTRAL TRANSFORMERLESS INVERTERS. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75655	13041-20000-08069	333 S HOPE ST STE 800	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/28/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.05326	-118.25292	Plan check for energy and emergency lighting. Suite 800. 8th floor of commercial high-rise. CAP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75656	15041-10001-36514	519 S SPRING ST	90013	14	129A211   133	5149034005	C5-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			01/03/2017 12:00:00 AM	01/05/2017 12:00:00 AM		Permit Finaled	05/16/2018 12:00:00 AM	ADDRESS	34.04699	-118.2503	01/03/17Changes to an approved set of plans. Changes include engineer on record, new interior/exterior lights, and new receptacles for dining area. Changes to reflect what is on the field per inspector's request. New total affected area is 2618 sq. ft. Plan check for Title 24 only. Project site is an existing commercial space. Project scope is a tenant improvement. Total lighting area = 2,600 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75657	16041-20000-15917	542 S ALAMEDA ST	90013	14	126A215   141	5163027011	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	07/25/2017 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	34.04014	-118.23809	NEW 1200 AMP SERVICE TO A NEW INDUSTRIAL WAREHOUSE TWO STORIES.  PLAN CHECK FOR POWER AND ENERGY.  TOTAL SQUARE FOOTAGE 12030.Note: Building application has been created under 16016-10000-10209	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75658	14041-10000-35914	1709 E MAURETANIA ST	90744	15	036B213   537	7425025020	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/30/2014 12:00:00 AM		Permit Finaled	02/17/2015 12:00:00 AM	ADDRESS	33.79051	-118.24201	Plan check for Title-24. Remove HID fixtures and replace with new LED fixtures. Total area: 2640	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75659	16041-10000-32883	540 S SANTA FE AVE	90013	14	126A217   221	5164004002	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM	04/21/2017 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	34.04042	-118.23057	PC for energy only for (E) commercial space. Outdoor lighitng only. Total sqft = 64924.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75660	15041-10000-39054	744 S HARTFORD AVE 1-24	90017	1	130-5A205 261	5143010009	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM	11/18/2015 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.05099	-118.2679	NEW FIRE ALARM SYSTEM TO A 24 UNIT APARTMENT. 1 FIRE ALARM PANEL WITH 72 FIRE ALARM DEVICES AND ONE POWER SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75661	13041-10000-30147	2651 W IVANHOE DR	90039	4	150A207   157	5439011009	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			10/28/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	01/14/2014 12:00:00 AM	ADDRESS	34.10537	-118.26339	PV1 6.24KWdc. 240V. microinverter. NONstd. ?story. Roofmount. [(24) inverters: {MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]}]. [(24)modules: {BenQ {PM250M01_260W}}]     'Expedited plan check per applicant request'	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75662	15041-20000-17182	600 WORLD WAY T6-S650	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	Plan check for Title 24 only. Project scope is an illuminated sign within Terminal 6 of LAX, Space 650.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75663	17041-20000-11725	6600 N TOPANGA CANYON BLVD 84b	91303	3	180B101   822	2139004044	UT(WC)-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM			PC Approved	04/11/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	ti to an existing commercial space in westfield mall.  plan check for energy only.  total square footage 5346.  plan check for energy only.Express permit issued under 17041-10000-19114.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75664	16041-20000-41653	8166 N WHITSETT AVE	91605	2	192B165   726	2308018007	RS-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	03/06/2018 12:00:00 AM	ADDRESS	34.21961	-118.40508	permit fee $0.00 by state senate bill no.1222pv1install roof mounted pv system (acm) sized 12.8kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75665	17041-10000-17514	10250 W SANTA MONICA BLVD # 1867	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	08/08/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full plan check, First tenant- retail store Sama Ste.# 1867	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75666	13041-20000-11475	5750 W WILSHIRE BLVD E1 ROOM	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/03/2013 12:00:00 AM			PC Approved	05/03/2013 12:00:00 AM	ADDRESS	34.06227	-118.3542	TI OF EXISTING ELECTRICAL ROOM. CHANGE IN LIGHTING. PC FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 280 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75667	12041-20000-19080	7601 W SUNSET BLVD	90046	4	147B177   950	5550006027	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			08/14/2012 12:00:00 AM	08/14/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.0982	-118.35523	energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75668	19041-20000-24367	14706-14708 W ARMINTA ST	91402	6	189B149   517	2210021021	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.30	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM	07/10/2019 12:00:00 AM		Permit Finaled	10/09/2019 12:00:00 AM	ADDRESS	34.2133	-118.4533	Plan check for power only. Service upgrade to 800A Over Head 120/240V 3 Phase 4 wire.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75669	13041-10000-09481	5904 N FIGUEROA ST	90042	1	151-5A229 137	5492015010	C2-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1837.01	Electrical	Electrical	Commercial			04/12/2013 12:00:00 AM	04/12/2013 12:00:00 AM		Permit Finaled	12/24/2013 12:00:00 AM	ADDRESS	34.11046	-118.19065	TI TO EXISTING BUILDING 1 story FOR RESTAURANT 1133 sf	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75670	15041-10000-24270	921 S CROCKER ST #C-12	90021	14	124-5A211 121	5132001054	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			Corrections Issued	07/29/2015 12:00:00 AM	ADDRESS	34.03582	-118.24984	PC FOR ENERGY ONLY, TI TO AN (E) RETAIL BUILDING. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 1130.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75671	17041-10000-21925	10250 W SANTA MONICA BLVD #1990	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/29/2017 12:00:00 AM	08/21/2017 12:00:00 AM		Permit Finaled	10/03/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Plan check for power and Title 24.  T.I. for first time tenant ""Monica Rich Kosann"" in Westfield Century City.  New jewelry retail space.  New 75 kVA transformer to feed two subpanels with lighting and receptacle loads.  Lighting area = 516 sq. ft."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75672	18041-20000-02663	11147 W LA MAIDA ST	91601	2	168B173   269	2353020020	R3-1	South Valley	North Hollywood - Valley Village	NoHo		1254.02	Electrical	Electrical	Apartment			01/24/2018 12:00:00 AM			Reviewed by Supervisor	02/14/2018 12:00:00 AM	ADDRESS	34.15885	-118.37383	Plan check for power and energy. Project site is a new 3-story, 8-unit apartment building. Work includes a new 800-amp service and a total lighting area of 12,857 sq. ft.Note: Building application has been generated under 17010-20000-03312	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75673	13041-10000-35421	16601 W RINALDI ST BLDG A-CULINARY	91344	12	213B137   476	2610014008	A1-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	Commercial			12/20/2013 12:00:00 AM	12/19/2016 12:00:00 AM		Issued	12/19/2016 12:00:00 AM	ADDRESS	34.27948	-118.49358	"FULL PLAN CHECK FOR POWER AND ENERGY TO NEW COMMERCIAL BUILDING. CONSTRUCTION OF 1 TWO STORY + BASEMENT BUILDING ( CULINARY). THIS IS DESIGNATED AS BUILDING ""A"" ON THE PLAN. Number of circuits, panels are for the 3 buildings  A,B and C. Plan checker please recalculate fees for the three buildings.BUILDING PERMIT: 13010-10000-04216"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75674	16041-20001-45393	10046 N SAMOA AVE	91042	7	202-5A199  24	2568006050	R3-2	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1012.10	Electrical	Electrical	Apartment			12/28/2016 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.25157	-118.28721	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75675	11041-10000-27008	8724 S CENTRAL AVE	90002	9	096A209    47	6043002020	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			12/19/2011 12:00:00 AM	12/19/2011 12:00:00 AM		Permit Finaled	12/22/2011 12:00:00 AM	ADDRESS	33.95858	-118.2562	one for one change out for 600a swbd/service ; same manufacturer;same loads and feeders ;same available short circuit current at the panel board	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75676	16041-10000-15762	13031 W JEFFERSON BLVD 2ND FLOOR	90066	11	102B157    51	4211008028	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			05/05/2016 12:00:00 AM	05/09/2016 12:00:00 AM		Permit Finaled	06/20/2016 12:00:00 AM	ADDRESS	33.97451	-118.42531	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR FOUR NEW OFFICE CUBICLES ON THE 2ND FLOOR. TOTAL AFFECTED AREA IS 500 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75677	12041-20000-27422	11374 W TUXFORD ST	91352	6	195B173   400	2408024003	M3-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.00	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	12/12/2012 12:00:00 AM	ADDRESS	34.22874	-118.37896	Plan check for energy only. 620 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75678	15041-10000-24111	390 N HARBOR BLVD	90731	15	018B201   449	7440026903	M2-1, [Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	05/31/2018 12:00:00 AM	ADDRESS	33.74502	-118.27676	PC FOR POWER. INSTALLATION OF 2 11 KV SHORE TO SHIP CONNECTIONS AMP BOXES, SWGEAR AN TC GEAR AND NEW TRANSFORMERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75679	16041-10006-01886	700-800 WORLD WAY TERM 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	06/16/2017 12:00:00 AM		Permit Finaled	08/06/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	Changes made to the previously approved set. changes reflected as delta 38.  (1) Revise few feeder lengths --> fault current and volt. drop adjusted(2) Revise total sq.ft for T24(3) Remove and add branch circuits on some panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75680	19041-20001-03884	14941 W DEVONSHIRE ST	91345	7	204B149   210	2648001013	A2-1-O	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.01	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM			Verifications in Progress	04/24/2019 12:00:00 AM	ADDRESS	34.25739	-118.45803	(expedite fees)pc for pv system. 34.3 kw DC and 30.9 AC. 98- REC350TP2S72 modules. 3 inverters (solaredge -se10000H). system is installed for a  church.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75681	11041-20000-16487	6628 N VAN NUYS BLVD	91405	6	180B149   336	2237001012	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.00	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM	08/05/2011 12:00:00 AM		Permit Finaled	10/28/2011 12:00:00 AM	ADDRESS	34.1915	-118.44844	office t.i.Energy , emergency	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75682	19041-20000-03151	9026 N WOODLEY AVE	91343	12	195B141    69	2672001004	(Q)C2-1VL, [Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	05/11/2020 12:00:00 AM	ADDRESS	34.23441	-118.48487	Plan check for Title 24 only in existing space Tenant Improvement. Total area: 4232 sq ft. B#19016-20000-02499	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75683	19041-10000-00978	1031 W WEST 34TH ST	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM	09/23/2019 12:00:00 AM		Issued	09/23/2019 12:00:00 AM	ADDRESS	34.02488	-118.28874	PLAN CHECK FOR POWER AND ENERGY FOR - INTERIOR ALTERATION  OF 5TH FLR OF A MEDICAL OFFFICE  TOTAL NEW CONNECTED LOAD IS APPROX 200A TO EXISTING SERVICE. TOTAL AFFECTED AREA = 11493 SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75684	13041-10001-24195	7432 S KENTWOOD AVE	90045	11	102B165   359	4110021011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2013 12:00:00 AM	10/31/2013 12:00:00 AM		Permit Finaled	11/08/2013 12:00:00 AM	ADDRESS	33.97563	-118.40151	SUPPLEMENTAL APPLICATION FOR 13041-10000-24195. ADDING 1 MODULE AND CHANGING INVERTER TO SOLAREDGE. NEW SYSTEM SIZE: 4.5 KW.ORIGINAL PC: PV1 TRANSFORMERLESS SYSTEM. 17 MODULES AND 1 INVERTER. TOTAL SYSTEM SIZE 4.25KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75685	11041-10002-20028	4051 S AVALON BLVD	90011	9	115-5A207 368	5113003013	M1-1	South Los Angeles	Southeast Los Angeles			2283.10	Electrical	Electrical	Commercial			05/14/2012 12:00:00 AM			PC Approved	05/14/2012 12:00:00 AM	ADDRESS	34.00996	-118.26553	Modification to lighting layout and fixture type from previously approved plan.<<<< SELF SERVICE LAUNDROMAT WITH ATTACHED CAR WASH/AUTOMOBILE LAUNDRY AND ATTACHED VACUUM SERVICE FOR CAR LAUNDRY,>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75686	17041-10001-41404	12700 W VAN NUYS BLVD Bldg 21&22	91331	7	210B161    63	2536010244	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			11/15/2017 12:00:00 AM			PC Approved	02/02/2018 12:00:00 AM	ADDRESS	34.27528	-118.4092	**fee expedited per applicantPV2, install new solar system, 15.2 kW AC system on a commercial (apartment) building: Building 21 and Building 22 interconnect.(63) modules with (63) power optimizer, and (2) 7.6 kW inverters, (1) load center	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75687	16041-10000-38382	9301 N TAMPA AVE #182	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			10/28/2016 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.2392	-118.55379	Plan check for Energy only, T.I. of kids footlocker. Reusing existing panel and circuits for lighting and receptacles. Total effected area: 2,605 sq.ft(Ref: B16WL05385)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75688	15041-20000-01921	20453 W RUSTON ROAD	91364	3	168A111   112	2174021001	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.15327	-118.57933	Fee is $0.00 due to 2012 State Senate Bill 1222.PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 15.0KW INTERCONNECTED WITH MSP.(46) SUNPOWER SPR-X21-345 MODULES(3) SUNNYBOY INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75689	17041-10000-11686	5855 W CENTURY BLVD	90045	11	090B169    11	4125025039	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			04/11/2017 12:00:00 AM	06/19/2017 12:00:00 AM		Issued	06/19/2017 12:00:00 AM	ADDRESS	33.94572	-118.38488	PC for Title 24. Change of use from retail to restaurant-takeout (no seating). New lighting and power. Area: 395 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75690	17041-10000-15044	1051 S QUEEN ANNE PL	90019	10	132B185   753	5082001011	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			05/05/2017 12:00:00 AM	10/04/2017 12:00:00 AM		Permit Expired	09/17/2023 12:00:00 AM	ADDRESS	34.05558	-118.33003	PC FOR ROOF MOUNTED PV SYSTEM WITH AC CONNECTED BATTERY.SYSTEM SIZE 7.6 KWAC (SOLAR EDGE)DC TESLA  POWER WALL BATTERY 3.3 KW (DC/DC)INCLUDING 8 MOUDULES WITH OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75691	18041-10001-25090	7261 W ESTEPA DR	91042	7	198B197    85	2562020015	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland-Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2018 12:00:00 AM			PC Approved	08/02/2018 12:00:00 AM	ADDRESS	34.2426	-118.29107	VOID.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75692	16041-10000-43539	10250 W SANTA MONICA BLVD UNIT 1860	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"First time tenant ""Oak + Fort"" , plan check for power and energy."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75693	17041-10000-04292	1430 W VENICE BLVD	90006	1	127-5A201 181	5056010001	CM-1	South Los Angeles	South Los Angeles	Pico Union		2211.20	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.04377	-118.28486	PC for outdoor Title 24 only. Removing HID fixtues and replacing them with new LED ones. Area: 10,975	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75694	16041-10000-20854	21900 W VANOWEN ST	91303	3	180B105    76	2139004047	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Issued	10/07/2016 12:00:00 AM	ADDRESS	34.19217	-118.60389	PC FOR T24 ENERGY ONLY. MOST OF LIGHTING IN MACY SHOWN ON PLANS WILL BE ALTERATION LESS THAT 10% IN THE SPACE. NO T24 IN 1ST AND 2ND FLOOR AREAS NEEDED. PC FOR PARTIAL 3RD FLOOR FOR NEW FIXTURES AND WIRING IN THOSE AREAS. TOTAL AREA OF REVIEW IS 1906 SQ FT. ALTERED AREAS HIGHLIGHTED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75695	10041-20002-04842	13164 W BURBANK BLVD	91401	5	174B157   656	2345005022	R1-1, [Q]RD2-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1236.01	Electrical	Electrical	Commercial			08/23/2010 12:00:00 AM	08/27/2010 12:00:00 AM		Permit Finaled	10/18/2010 12:00:00 AM	ADDRESS	34.17196	-118.4201	delta 6 revisions to 02041-20000-12117. changing 60 amp to 200amp panel and some circuits for future loads.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75696	13041-20000-29052	24425 W CALVERT ST	91367	3	177B089   851	2032011074	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1352.03	Electrical	Electrical	Commercial			10/17/2013 12:00:00 AM	10/30/2014 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.18297	-118.65673	PHASE 2. FULL PLAN CHECK FOR POWER AND ENERGY FOR FIRST TIME OCCUPANCY OF NEW BUILDINGS FOR DAY CARE CENTER. TO TIE INTO EXISTING SERVICE UNDER ORIGINAL ELECTRICAL PLAN CHECK UNDER 13041-20000-17143	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75697	10041-10000-01380	5990 N SEPULVEDA BLVD #200	91411	2	177B145   487	2243019023	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			01/26/2010 12:00:00 AM	01/29/2010 12:00:00 AM		Permit Finaled	02/25/2010 12:00:00 AM	ADDRESS	34.17911	-118.46588	remodel officesplan chkis for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75698	19041-10000-38662	4954 E MERIDIAN ST	90042	14	156A225   194	5476017014	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.12232	-118.20699	PLAN CHECK FOR ROOF MOUNTED 3.8KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE3800H-US) WITH 15 MODULES USING P320 OPTIMIZERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75699	15041-20000-22809	5245 N LANKERSHIM BLVD	91601	2	171B173   439	2350017034	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			07/17/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.16601	-118.37573	Title 24 plan check only.  Total area = 1,773 sq. ft.  T.I. to existing restaraunt space.  New lighting only.investigation fee charged under this permit. Date: 4-20-15INSPECTOR: GeorgeDistrict #:PHONE:818-374-1134investigation due to new lighting, plugs, switches without permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75700	13041-10000-32708	9020 N RESEDA BLVD BLDG A	91324	12	195B125    51	2769001028	C2-1VL, P-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM	06/04/2014 12:00:00 AM		Permit Finaled	10/23/2014 12:00:00 AM	ADDRESS	34.2346	-118.53587	INSTALLING (2) NEW SERVICES TO (2) BUILDINGS ('A' AND 'B'). BUILDING 'A' IS NEW, AND BUILDING 'B' IS FOR A REMODEL TO EXISTING BUILDING. THIS APPLICATION IS FOR BUILDING 'A'. ADDING NEW 800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75701	15041-20002-07849	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/05/2015 12:00:00 AM			PC Approved	08/05/2015 12:00:00 AM	ADDRESS	34.12774	-118.26247	08/05/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 5. Changes include the addition of  receptacles and lights onto existing circuits.*****Previous Work Description*****Change to approved set. Plan check for Addition of 2  new hearing exam booths to Costco. No light is being add to the 2 new booth; light is part of the booth. {{{{{{PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COSTCO OPTOMETRY ROOMS. NOT A MEDICAL ( CONSULTATION ONLY) 615 SQFT.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75702	15041-20001-30241	1922 W 82ND ST	90047	8	099B193  1351	6035015009	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Expired	10/20/2017 12:00:00 AM	ADDRESS	33.96447	-118.31208	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.32 KWNote: Solar clearance refer to 15041-20000-30241	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75703	14041-20002-33422	3201 S OVERLAND AVE 1-525	90034	5	120B161     7	4254011036	R1-1, R3-1, R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	Apartment			03/27/2015 12:00:00 AM			PC Approved	06/08/2015 12:00:00 AM	ADDRESS	34.02928	-118.41552	[[[[6/8/15  changes to approved set. plancheck only. system size: 298 kwdc. 962 canadian solar modules. 3 sma 24ktl , 7 sma 20ktl and 2 sma 15ktl. ]]]]](((((((((Permit fee is $0.00 due to 2012 State Senate Bill 1222.PV2.Install a roof-mounted solar array on a 525 unit apartment building. Interconnect with 1200A MSP.System size: 301kW (Seven 23kW inverters & Five 28kW inverters). Ungrounded system.999  310W pv modules. Equipment shown as 'Future' is to be installed under this permit, include in plan check.))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75704	16041-20000-12900	11540 W BLIX ST	91602	2	168B169   600	2354016053	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2016 12:00:00 AM	04/27/2016 12:00:00 AM		Permit Expired	05/29/2018 12:00:00 AM	PIN	34.1564198	-118.38356444	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW. Ungrounded system. Each module has a 300W power optimizer.(36) 270W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75705	11041-10000-23007	25965 S NORMANDIE AVE	90710	15	033B197    36	7411022025	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM			PC Info Complete	02/01/2012 12:00:00 AM	ADDRESS	33.78734	-118.29768	TI IN AN EXISTING 3 STORY MEDICAL BULDING.  (ALL EXISTINIG PANELS AND CIRCUITS - TO BE VERIFIED) PLAN CHECK FOR POWER & ENERGY CALCS.  **Per Engineer, the net added load is less than 3A, no demand provided.  Subject to field inspection, demand load may be requested.**	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75706	19041-10000-22520	550 S HOPE ST # 420	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75707	15041-20001-29568	15541 W LEMAY ST	91406	6	180B141   206	2234004023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.10	Electrical	Electrical	1 or 2 Family Dwelling			09/08/2015 12:00:00 AM			PC Approved	09/14/2015 12:00:00 AM	ADDRESS	34.1913	-118.47323	PV1. ROOFMOUNTED SOLAR SYSTEM. (1) INVERTER: ABB FORNIUS PVI-4.2-OUTD-US-Z-A(1) INVERTER: ABB FRONIUS PVI-3.6-OUTD-US-Z-A(39) MODULES #KU2656ZPA**ZERO FEES UNDER CA SENATE BILL FOR SOLAR INSTALLATION, PERMIT UNDER 15041-20000-29568	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75708	09041-30001-24271	11684 W SAN VICENTE BLVD	90049	11	129B145    37	4265006063	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM			PC Approved	01/19/2010 12:00:00 AM	ADDRESS	34.05358	-118.46475	1 - 12 -10 - Supplemental is for T-24 P/C reqeusted by inspector.  P/C is for Energy only :: INSTALL NEW OUTLETS AND LIGHTING CIRCUITS AND LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75709	16041-20000-26901	859 S LUCERNE BLVD 1-14	90005	4	132B189   451	5090020001	R3-1-HPOZ	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Apartment			07/29/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.05885	-118.32597	New 4-story 14 unit apartment building with two levels subterranean parking.  Plan check for power and energy.  Methane buffer zoneModification to request separation of fire alarm plans filed 09/08/16	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75710	19041-10000-05458	12450 W MAGNOLIA BLVD	91607	2	171B165  1236	2356020023	R1-1, RD1.5-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.16467	-118.40459	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75711	16041-20000-12644	8715 N TOBIAS AVE	91402	6	195B149   570	2653003123	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.03	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.2286	-118.45189	Plan check for power and energy. Project site is a new 4-story, 27-unit apartment building. Total lighting area = 21,562 sq. ft.Note: Building permit has been pulled under 05010-20000-07064	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75712	13041-20000-31618	14209 W GAULT ST PV1	91405	6	183B153   291	2217022078	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.19954	-118.44268	NEW 4.578KW ROOFTOP PV SYSTEM FOR AN EXISTING SINGLE FAMILY DWELLING.  SYSTEM IS UNGROUNDED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75713	10041-20000-04541	17245 W VENTURA BLVD	91316	5	171B133   679	2258012022	[Q]C2-1VL	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	Commercial			03/12/2010 12:00:00 AM	04/06/2010 12:00:00 AM		Permit Finaled	06/09/2010 12:00:00 AM	ADDRESS	34.16084	-118.50856	CHANGING THE USE FROM CANDY SHOP ( RETAIL ) TO YOGURT SHOP W/ OUTDOOR DINING AREA ( RESTAURANT ). New 400 amp service from new upgraded 1200 amp underground service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75714	15041-20001-20801	23509 W WINDOM ST	91304	12	186B093   241	2027036002	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.20669	-118.64062	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (3) inverters, (50) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75715	18041-20001-03840	3650 N LANKERSHIM BLVD	90068	4	159B173    64	2380001007	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM			PC Approved	02/12/2018 12:00:00 AM	ADDRESS	34.13588	-118.36657	Plan check for the addition of a PV1 roof-mounted PV system and a battery storage system to an existing PV system. System addition size is 3.1 kWac and consists of (11) modules, (11) micro-inverters, (1) load center, and (1) Tesla PowerWall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75716	17041-10000-23342	11401 N PORTER RANCH DR BLDG 9	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Apartment			07/20/2017 12:00:00 AM	03/27/2019 12:00:00 AM		Permit Finaled	03/03/2021 12:00:00 AM	ADDRESS	34.2779	-118.57107	Plan check for power.  New 3 floor 20 unit apartment with 1200 amp 208 volt service.       Building 9 of 10.  Type I.       Building permit #17010-10000-02386	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75717	16041-20000-08241	6316 N TOPANGA CANYON BLVD B2170	91367	3	180B105    60	2146029020	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			03/09/2016 12:00:00 AM	03/29/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.18578	-118.60514	Plan check for power and energy. Core and shell (White Box - no tenant) for empty tenant space in Westfield Village at Topanga mall. 1,700sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75718	13041-20000-07539	741 N ALTA VISTA BLVD	90046	5	141B181   351	5525012003	R1-1	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	08/19/2013 12:00:00 AM	ADDRESS	34.0848	-118.34756	New 10.32kw PV System for a rooftop of an existing single family residence.  SYSTEM IS UNGROUNDED, not to be done on the standard plan.  System has two inverters combined with a sub-panel.  System is in a methane zone, NO CONDUIT IS TO BE RUN BELOW GRADE PER APPLICANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75719	14041-20000-05245	22341 W DOLOROSA ST	91367	3	174B101   324	2146011003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	1 or 2 Family Dwelling			02/26/2014 12:00:00 AM	06/19/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.1703	-118.61373	PV1 MICROINVERTER. TOTAL SYSTEM SIZE 9KWAC. MODULES MOUNTED ON PATIO STRUCTURE, REQUIRES BUILDING APPROVAL PRIOR TO ELECTRICAL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75720	13041-20000-22319	21650 W OXNARD ST FLR 10	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			08/16/2013 12:00:00 AM			PC Approved	08/16/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	Plan check for energy. 10th floor of commercial high-rise. Addition of offices. AIG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75721	17041-20000-17580	1349 N BEREA PL	90272	11	129B129    24	4422007039	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2017 12:00:00 AM	07/24/2017 12:00:00 AM		Permit Finaled	11/08/2017 12:00:00 AM	ADDRESS	34.05353	-118.52181	permit fee $0.00 by state senate bill no. 1222PV1. ROOFMOUNTED SOLAR SYSTEM. MICROINVERTERS. SYSTEM SIZE: 16 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75722	11041-10000-13837	735 S FIGUEROA ST Level M1&-M2	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/05/2011 12:00:00 AM			PC Info Complete	12/21/2011 12:00:00 AM	ADDRESS	34.04878	-118.26079	T.I. of the the lower level food court located at the 7th and Fig complex.  Full plan check.  See levels M1 and M2.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75723	14041-10000-07315	389 TERMINAL WAY ADMIN	90731	15	018B201   298	7440026903	M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Public Safety Only			03/19/2014 12:00:00 AM	04/03/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	PIN	33.74647892	-118.27942177	Upgrade fire alarm system for port of LA Administration BLDG. (1 of 3)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75724	14041-20001-26081	4835 N OAK PARK AVE	91316	5	168B133   168	2289004009	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2014 12:00:00 AM			PC Approved	10/06/2014 12:00:00 AM	ADDRESS	34.15873	-118.50467	expedite per customer request.PV1.  Install 14.5 kW roof-mounted, utility-interactive PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75725	18041-20000-10121	8505 S WESTERN AVE	90047	8	097-5A193 263	6035032039	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2381.00	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/23/2018 12:00:00 AM		Permit Finaled	11/26/2018 12:00:00 AM	ADDRESS	33.96069	-118.30921	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from grocery store to charter school/tenant improvement. Total lighting area = 11,465 sq. ft. Occpuant load is 228.  Note: Building application has been generated under 16016-10000-12653.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75726	15041-10000-00256	1060 S HOPE ST	90015	14	127-5A207 254	5139008010	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/07/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	11/03/2015 12:00:00 AM	ADDRESS	34.04228	-118.26281	PC for energy and power. T.I. Change of use from manufacture to office in an existing 6 story building.(levels 1 to 6). Total area 59261 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75727	14041-10000-23116	138-140 N SAN FERNANDO ROAD	90031	1	139-5A219 122	5447014024	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			08/25/2014 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Closed	03/07/2016 12:00:00 AM	ADDRESS	34.07531	-118.22164	PC for power. Upgrading  existing  service  to 800 amp 120/240v 3 phase.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75728	18041-10001-49144	14931 W MCKENDREE AVE	90272		129B129    69	4422012014							Electrical	Electrical	1 or 2 Family Dwelling			12/31/2018 12:00:00 AM			PC Approved	02/08/2019 12:00:00 AM	ADDRESS	34.05272	-118.52255	PC FOR PV AND ENERGY STORAGE SYSTEM. SCOPE INCLUDE  (MODEL: TESLA  AC POWERWALL 2.0) CAPACITY 27KWH STORAGE SYSTEM. NEW 200A LOAD CENTER.  NEW 31 PV MODULES (HANWHA Q-CELLS #Q.PEAK-G4.1/SC305), INVERTER SOLIVIA 7.6 TL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75729	15041-20000-21214	15729 W MCKEEVER ST	91344	12	210B141   217	2662010028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1092.00	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2015 12:00:00 AM	07/06/2015 12:00:00 AM		Permit Finaled	07/15/2015 12:00:00 AM	ADDRESS	34.27469	-118.47456	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6KW. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75730	11041-20000-22197	1880 CENTURY PARK EAST 8,9-Floors	90067	2	135B161    42	4319001001		West Los Angeles				2671.00	Electrical	Electrical	Commercial			10/17/2011 12:00:00 AM	10/17/2011 12:00:00 AM		Permit Finaled	11/14/2011 12:00:00 AM	PIN	34.06321806	-118.4136341	Plan check T24 Energy/Emergency for corridors on floors 8,9. Existing ckts.Fire/ Life safety existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75731	11041-20000-02074	1800 S AVENUE OF THE STARS	90067	5	132B161    15	4319002046	C2-2-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Public Safety Only			02/02/2011 12:00:00 AM	04/04/2011 12:00:00 AM		Permit Finaled	04/19/2012 12:00:00 AM	ADDRESS	34.06095	-118.41786	Plan check for fire alarm system upgrade for high-rise building. Replace all existing devices and panels. Use existing wiring except for 3rd floor. New wiring for 3rd floor only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75732	17041-10000-20051	3470 W 6TH ST #2A	90020	10	135B197  1033	5502029026	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.02	Electrical	Electrical	Commercial			06/14/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	07/13/2017 12:00:00 AM	ADDRESS	34.06339	-118.29748	PC FOR TITLE 24 ENERGY ONLY ADD COUNTER TO EXISTING RESTAURANT (NO CHANGE OF USE).SCOPE INCLUDES NEW LIGHTS INSTALLED ABOVE NEW COUNTER SPACE. TOTAL AFFECTED AREA 1770 SQ.FT.PARTIAL PERMIT PULLED UNDER 17041-10000-15802BL#17016-10000-07497	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75733	19041-10000-46363	3130 W WILSHIRE BLVD	90010	10	132B197    37	5077011015	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2122.03	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Issued	11/12/2019 12:00:00 AM	ADDRESS	34.06164	-118.28991	PV1. NEW ROOFTOP SOLAR SYSTEM CONSIST OF 21 MODULES (Q-CELL 285) , 21 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE5000H-US).  SYSTEM SIZE IS 5.985KWdc and 5KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75734	17041-10000-21998	19751 W MARIPOSA CREEK WAY	91326	12	213B113   164	2701028038	RD6-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	Yes	1082.01	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.28213	-118.56623	Installation of new roof mounted solar PV system on existing single family dwelling.  Total system size = 6 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75735	16041-20000-43263	20750 W VENTURA BLVD ste 400	91364	3	171B109    85	2166014020	(Q)C1-1VLD, (Q)C1.5-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Commercial			12/09/2016 12:00:00 AM	12/09/2016 12:00:00 AM		Permit Finaled	06/29/2017 12:00:00 AM	ADDRESS	34.16638	-118.58506	ti to an existing commercial building.  adding new lighting new contrls to existing panels.  total square footage 3855.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75736	19041-20002-09441	20061 W SATICOY ST	91306	3	186B113   176	2106006041	C2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1341.01	Electrical	Electrical	Commercial			04/15/2019 12:00:00 AM			PC Approved	04/15/2019 12:00:00 AM	ADDRESS	34.20848	-118.57071	Title 24 energy plan check per inspector correction notice.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75737	14041-20000-08338	9356 N GEYSER AVE	91324	12	198B121   269	2763017010	RS-1	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2014 12:00:00 AM	04/17/2014 12:00:00 AM		Permit Expired	05/11/2016 12:00:00 AM	ADDRESS	34.24078	-118.54236	PV1. Install 4 kW roof-mounted PV system, interconnect with main service panel.  Transformerless inverter: SolarEdge SE3800A-US-ZB-U.  16 modules: Canadian Solar CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75738	18041-20000-11247	7235 N CEDAR ROAD	91405	2	186B153   941	2217032110	(T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	Commercial			03/28/2018 12:00:00 AM	03/28/2018 12:00:00 AM		Permit Finaled	04/09/2018 12:00:00 AM	ADDRESS	34.20236	-118.44077	PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.25 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75739	10041-10000-17593	1249 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			09/16/2010 12:00:00 AM	11/18/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.05096	-118.22622	Solar voltaic system installed on the roof of the building.  Consists of  8 modules,  8 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75740	11041-20000-11263	2049 S CENTURY PARK EAST 11TH FL	90067	5	132B161   698	4319016030		West Los Angeles				2679.01	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM			PC Approved	06/01/2011 12:00:00 AM	ADDRESS	34.05903	-118.41293	PLAN CHECK T24 ENERGY GENERAL LIGHTING FOR OFFICE TI ON THE 11TH FL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75741	18041-20000-16991	5071 N LLANO DR	91364	3	171B101  1182	2169024013	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Issued	05/30/2018 12:00:00 AM	ADDRESS	34.16054	-118.60952	Plan check for PV roof mounted system connected to an existing PV system, New PV system size: 21.96 kWac with 61 AC Modules connected to existing 400A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75742	19041-10000-35801	1000 S HILL ST	90015	14	126A209    76	5139013018	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM	04/22/2022 12:00:00 AM		Issued	04/22/2022 12:00:00 AM	ADDRESS	34.04139	-118.2584	Power plan check for a temp' power of a high rise building. Scope include a new 1600-Amp board, (4) panels and other associated equipment. Note. power source is supplied by a different building located from a different property.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75743	15041-20003-40370	7631 W BECKETT ST	91042	7	204A197   283	2558035021	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM			PC Approved	05/13/2016 12:00:00 AM	ADDRESS	34.25381	-118.299	05-12-16 Changes to approved set of plans. Changes include relocate one module and update PV breaker size to 40A. {{{{{PV1.  Install 5.16 kW roof-mounted, utility-interactive PV system.  (21) Silvantis F-Series 270W w/ (1) SolarEdge SE5000A-US transformerless inverter.}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75744	18041-10000-35093	20350 W PRAIRIE ST	91311	12	198B113   140	2748039019	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.23896	-118.57718	REMOVE INDOOR-OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75745	10041-20000-04297	1200 W 7TH ST FLOOR-7	90017	1	130-5A207 184	5143006013	CW	Central	Westlake			2093.00	Electrical	Electrical	Commercial			03/10/2010 12:00:00 AM			PC Approved	03/10/2010 12:00:00 AM	ADDRESS	34.05136	-118.26616	RELOCATING AND INSTALLING NEW LIGHT FIXTURE IN OFFICE SPACE. THIS PLAN IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75746	16041-20000-01991	527 N WESTMORELAND AVE	90004	13	141B197   890	5539031008	R3-1	Central	Wilshire	East Hollywood		1927.00	Electrical	Electrical	1 or 2 Family Dwelling			01/20/2016 12:00:00 AM	02/03/2016 12:00:00 AM		Permit Finaled	03/15/2016 12:00:00 AM	ADDRESS	34.08071	-118.28813	Plan check for PV roof mounted system. System size: 10kW with 36 modules and 1 inverter(10kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75747	13041-10000-11378	4420 W SUNSET DR	90027	4	147A201   110	5542009016	C2-1	Central	Hollywood	Greater Griffith Park		1953.00	Electrical	Electrical	Commercial			05/02/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.09803	-118.28588	PERMIT TO BE PULLED AT EPC COUNTER ONLY. PC FOR ENERGY. NEW COFFEE SHOP FROM EXISTING HOTEL ADDITION. 292 sf. less than 400A per applicant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75748	19041-20001-43058	14903 W VICTORY BLVD	91411	6	180B149   840	2235021046	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.06	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM			PC Approved	12/04/2019 12:00:00 AM	ADDRESS	34.18683	-118.45764	Expedited plan check fee.PV3.  Install 20.72 kW DC roof mounted grid tied PV system.  (56) modules with (28) microinverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75749	12041-10000-31092	4371 S CRENSHAW BLVD A	90008	8	111B185    83	5024006013	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			12/27/2012 12:00:00 AM	12/05/2013 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.00372	-118.3325	TI. OF RESTARAUNT. T24 ONLY. 1492 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75750	15041-20001-14543	8435 N ORION AVE	91343	6	192B141   304	2654029033	(T)(Q)R3-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Apartment			04/16/2018 12:00:00 AM			PC Approved	04/16/2018 12:00:00 AM	ADDRESS	34.22384	-118.47239	PC only for changes to approved set. Changing house panel circuit layout. Removing dimmers from bedrooms since lighting in bedrooms is high efficacy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75751	15041-20000-14835	15503 W WYANDOTTE ST	91406	6	186B145   756	2222024017	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Expired	06/09/2017 12:00:00 AM	ADDRESS	34.20311	-118.47078	Plan check for PV roof monted 8.0kWac system with 33 modules (Kyocera) and 2 inverters(3.0kW and5.0kW )	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75752	13041-20000-34741	1642 S FEDERAL AVE 1-8	90025	11	126B149   283	4261013031	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			12/13/2013 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	08/18/2015 12:00:00 AM	ADDRESS	34.04365	-118.4529	New 8-Unit Apartment Building.  800 amp service.  Variance to separate fire alarm has been paid.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75753	13041-10001-30908	18815 W CELTIC ST	91326	12	210B121   669	2717022022	RE11-1	North Valley	Northridge	Northridge West		1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.26884	-118.54336	Expedited RSES plan check per applicant request. PV1, Install 3.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 15 modules Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75754	19041-10000-04284	3444 E WHITTIER BLVD	90023	14	121-5A227 171	5188017004	C1.5-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2048.10	Electrical	Electrical	Commercial			02/05/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Issued	04/23/2019 12:00:00 AM	ADDRESS	34.02706	-118.1997	"PC PWR AND T-24. ADDITION OF NEW ELEVATOR, MACHINE ROOM, AND GROUND FLOOR TO EXISTING MEDICAL OFFICE BUILDING, INCLUDING INT AND EXT TENANT IMPROVEMENTS. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75755	13041-10001-35345	2612 N ROUND DR	90032	14	141A235   413	5217012014	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	03/10/2014 12:00:00 AM	ADDRESS	34.07852	-118.17236	Expedited RSES plan check per applicant request.{{PV1, Install 5 kW DC roof-mounted solar array, interconnect with main service panel for a one story house. (1)Transformerless inverter: Solaredge SE 5000A-US. (20) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75756	19041-20000-10378	9300 S SUCCESS AVE	90002	15	094-5A211  87	6048001030	R3-1	South Los Angeles	Southeast Los Angeles	Watts		2423.00	Electrical	Electrical	Apartment			03/22/2019 12:00:00 AM			PC Info Complete	08/20/2019 12:00:00 AM	ADDRESS	33.95217	-118.24875	800A 240/120V 1ph-3w, power, and lighting for new apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75757	16041-10001-45651	5135 W ADAMS BLVD	90016	10	123B177   884	5049009050	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			05/13/2019 12:00:00 AM	05/22/2019 12:00:00 AM		Permit Finaled	09/16/2019 12:00:00 AM	ADDRESS	34.03265	-118.35318	Supplemental plan check for delta 7 changes to an approved set. Changes to T-24, Indoor and outdoor lighting. T-24 Only. Total affected area is  12466 sq.ftOriginal((Full Plan check for a new 3 story, 10 unit mix use building with subterrenean parking. New service rated at 800 amps 240/120V 3phase 4wire. Total area: 8410.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75758	17041-20000-39719	2587 N HUTTON DR	90210	5	153B157    60	4382010005	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2017 12:00:00 AM	11/09/2017 12:00:00 AM		Permit Finaled	01/25/2019 12:00:00 AM	ADDRESS	34.11884	-118.43191	addition of (3) tesla power walls.  plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75759	19041-10001-04426	16901 W ENCHANTED PL	90272	11	129B121   160	4419001043	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2019 12:00:00 AM			PC Approved	03/11/2019 12:00:00 AM	ADDRESS	34.05166	-118.54814	FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED 20KVA PV SYSTEM CONSISTING OF 2 CENTRAL INVERTERS (SOLAREDGE SE 10000H-US) WITH 61 MODULES USING (P370) OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75760	16041-20001-28850	9201 N WINNETKA AVE	91311	12	198B113   208	2748039026	P-1, [Q]M2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			10/21/2016 12:00:00 AM			PC Approved	10/21/2016 12:00:00 AM	ADDRESS	34.2374	-118.57146	10/21/2016 Plan check for power only. Project site is an existing theater (place of assembly). Scope is (2) panels, (2) transformers, and receptacles for electric theater chairs.*****Previous Work Description*****ADD (2) 200 AMP PANELS AND (44) NEW CIRCUITS FOR RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75761	16041-20000-21825	1633 W 11TH ST	90015	1	129A203   162	5137016012	C1-1-HPOZ	Central	Westlake	Pico Union		2095.20	Electrical	Electrical	Commercial			06/21/2016 12:00:00 AM	10/06/2017 12:00:00 AM		Permit Finaled	10/11/2018 12:00:00 AM	ADDRESS	34.04818	-118.27573	PLANCHECK FOR POWER AND ENERGY. NEW 2-STORY SCHOOL BLDG WITH A NEW 800 AMPS SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75762	17041-10000-12205	1999 S AVENUE OF THE STARS #2810	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	04/20/2017 12:00:00 AM		Permit Finaled	05/31/2017 12:00:00 AM	ADDRESS	34.05886	-118.41642	Plan check for Title 24 only in existing office sapce. T.I.  Total area: 2,465 sq ft.B#17016-10000-05116	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75763	18041-10000-12184	9864 W NATIONAL BLVD	90034	5	123B165   967	4311005014	C2-1, P-1	West Los Angeles	West Los Angeles	South Robertson		2698.00	Electrical	Electrical	Commercial			04/04/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.0307	-118.40168	PLAN CHECK FOR T24 ONLY FOR SIGNAGE.TENANT IMPROVEMENT TO ADD LIGHTED RINGS IN THE SALES AREA FOR SINAGE.THIS IS PLAN CHECK ONLY, PERMIT TO BE PULLED SEPARATLY. EMERGENCY LIGHTS AND EXIT SIGNS ARE REMAIN THE SAME AND NOT PART OF THE SCOPE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75764	18041-20000-45083	4248 S STEWART AVE	90066	11	108B157   256	4231017022	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.11	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	33.99496	-118.42757	PV1.  Install 13.53 kW DC roof mounted grid tied PV system.  (41) modules with 7.6 and 5 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75765	19041-10000-35998	8091 W SELMA AVE	90046	4	147B173   179	5555030002	C4-1D	Central	Hollywood	Hollywood Hills West		1942.00	Electrical	Electrical	Commercial			09/10/2019 12:00:00 AM			PC Info Complete	09/10/2019 12:00:00 AM	ADDRESS	34.09839	-118.36694	ENERGY PC ONLY FOR  CHANGE OF USE FROM OFFICE TO NEW RESTAURANT WITH UNCOVERED OUTDOOR DINING. AREA OF SCOPE 2,139SF.BUILDING PERMIT: 16016-10000-27620	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75766	19041-10001-31160	806 E 61ST ST	90001	9	105B205   594	6007009014	M2-1-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2392.02	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM			PC Approved	12/09/2019 12:00:00 AM	ADDRESS	33.98431	-118.26099	PLAN CHECK ONLY FOR CHANGES TO APPROVED SET, SCOPE OF WORK IS REVISIONS TO LIGHTING LAYOUT, NOTE ALL PERMITS ARE TO BE PULLED ON MASTER PERMIT (19041-10000-31160). NOTE ALL CHANGES ARE CLOUDED UNDER DELTA 1. ORIGNAL SCOPE OF WORK ((PLAN CHECK FOR ENERGY ONLY TO A WAREHOUSE TENANT IMPROVEMENT FOR NEW PARTITIONS, NEW ACCESSIBLE RESTROOMS AND EXTERIOR ALTERATIONS. SCOPE OF WORK INLCUDES NEW LIGHTING AND RECEPTACLES. SERVICE IS PLAN CHECK UNDER SEPARATE APPLICATION # 19041-10000-23889.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75767	13041-10000-01282	3650 W MARTIN LUTHER KING, JR BLVD	90008	8	114B185   183	5032002053	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			01/17/2013 12:00:00 AM			Ready to Issue	02/05/2013 12:00:00 AM	ADDRESS	34.01118	-118.33649	T24 for existing dressing room for an existing TJ Maxx. Sqr footage: 942. Using tailored method. Second floor of the mall. Two story building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75768	15041-10000-06852	555 W 5TH ST Ste 630	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	05/08/2015 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI to (E) 2,674 sq. ft. commercial office space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75769	12041-10000-26501	3150 W WILSHIRE BLVD	90010	10	132B197   112	5077010023	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2122.03	Electrical	Electrical	Commercial			11/05/2012 12:00:00 AM	01/08/2013 12:00:00 AM		Permit Finaled	04/29/2014 12:00:00 AM	ADDRESS	34.06163	-118.29086	Fire alarm system for new high rise building with 23-story 200-unit apartment (East Tower)  and  29-story 264-unit apartment (West Tower) over retail/restaurant and parking garage.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75770	18041-20000-39784	10108 W MCBROOM ST	91040	7	207B181   127	2543009017	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM	10/17/2018 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.26239	-118.35094	Plan check for PV roof-mounted solar PV system, System size: 11.6kW DC, 10KW AC with 40 PV modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75771	19041-20000-16623	2366 N HOBART BLVD	90027	4	153B193   229	5588014019	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.11375	-118.30318	PLAN CHECK ROOF MOUNTED PV SYSTEM FOR EXISTING SFD. SYSTEM SIZE IS 13.12KW DC/11.4KW AC//11.72 KW AC CEC. SCOPE OF WORK INCLUDES A (41) SILFAB MODULES WITH P320 OPTIMIZERS AND A SE11400 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75772	11041-20000-26675	8900 N DE SOTO AVE Blg 101	91304	12	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			12/14/2011 12:00:00 AM	12/14/2011 12:00:00 AM		Permit Finaled	01/23/2012 12:00:00 AM	ADDRESS	34.23162	-118.58832	T24 lighting plan check for remodeled room.  Permit is for branch circuits, and other equipment in remodeled area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75773	13041-20000-18415	8162 W MELROSE AVE	90048	5	141B173   462	5528011003	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/12/2013 12:00:00 AM			PC Info Complete	07/25/2013 12:00:00 AM	PIN	34.08346258	-118.36739586	RENOVATION OF EXISTING RESTAURANT. PLACE OF ASSEMBLY. TOTAL AREA OF RENOVATION 3195 SQ FT. AND 420 SQ FT. FOR OUTDOOR. PC FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75774	16041-10000-18421	777 E WASHINGTON BLVD	90021	14	121-5A209 166	5131004035	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			05/25/2016 12:00:00 AM	05/25/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.02683	-118.25514	PC for T-24 only.  Remove HID fixtures and replace with new LED fixtures. Total atea: 15,033 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75775	14041-10000-06920	8141 S GULANA AVE	90293	11	096B153     1	4115021800	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.01	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			Reviewed by Supervisor	03/26/2014 12:00:00 AM	ADDRESS	33.96169	-118.43753	PLANCHECK FOR POWER. MCC 100 AND MCC101 ARE REPLACE WITH NEW IDENTICAN MCC'S IN NEW LOCATION. SOME CABLE TRAYS AND CABLES REATTACHED IN HAZARDOUS AREAS.  NEW FEEDERS AND REWIRING. ALL LOADS AND MOTORS ARE EXISTING TO REMAIN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75776	15041-20001-35946	10585 W BUTTERFIELD ROAD	90064	5	126B161   610	4318014023	R1-1-O	West Los Angeles	West Los Angeles	Westside		2693.00	Electrical	Electrical	1 or 2 Family Dwelling			10/27/2015 12:00:00 AM			PC Approved	11/04/2015 12:00:00 AM	ADDRESS	34.03794	-118.41665	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 2 kWac and consists of (8) modules and (8) micro-inverters. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75777	15041-10001-43596	708 W Q ST	90744	15	036B205   545	7414031016	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2016 12:00:00 AM			PC Approved	03/08/2016 12:00:00 AM	ADDRESS	33.79484	-118.27155	03/08/16PC ONLY FOR A 3KW PV SYSTEM, WITH 12 MODULES AND ONE 3KW INVERTER. (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75778	16041-20000-04094	15937 W ARMINTA ST	91406	6	189B141   128	2206007024	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	PIN	34.21419799	-118.48096065	Plan check for Title 24 only for new Wearhouse/office. Total area: 1,600 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75779	12041-20000-10899	11639 W KLING ST	91602	2	168B169   672	2354017011	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2012 12:00:00 AM			Reviewed by Supervisor	05/22/2012 12:00:00 AM	ADDRESS	34.1559	-118.38687	INSTALL ROOF MOUNTED PHOTOVOLTAIC SOLAR SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75780	18041-10000-05679	14920 W RAYMER ST	91405	6	189B145   486	2209043036	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			02/22/2018 12:00:00 AM	09/18/2018 12:00:00 AM		Permit Finaled	05/15/2020 12:00:00 AM	ADDRESS	34.21302	-118.45859	PC for 465kW(ac) roofmounted solar system for Target. Installing 1568 PV panels (556.64kW(DC)) , six inveter and 800A distribution panel.PERMIT FEE IS $ 0 ACCORDING TO AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75781	17041-20000-17304	11979 W WALNUT LANE 1-4	90025	11	126B145  1090	4259012013	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	Apartment			05/23/2017 12:00:00 AM			PC Info Complete	06/13/2017 12:00:00 AM	ADDRESS	34.03749	-118.4591	PLANCHECK FOR POWER AND ENERGY.  4 UNITS APARTMENT WITH 4 STORY OVER SUBTERRANEAN GARAGE.building permit # 15010-10000-02913	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75782	16041-20000-36730	4215 S GLENCOE AVE	90292	11	108B153  1423	4230032***	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			12/28/2016 12:00:00 AM	11/20/2018 12:00:00 AM		Permit Finaled	06/20/2019 12:00:00 AM	ADDRESS	33.98812	-118.44136	"Plan check for power only. Project site is an existing apartment complex. Project scope is the addition of distribution equipment ""MSD"" and ""MSE"" for future EV chargers."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75783	11041-10000-22280	1243 W 6TH ST	90017	1	132A207   205	5153022010	CW	Central	Westlake		YES	2091.01, 2091.02	Electrical	Electrical	Apartment			10/18/2011 12:00:00 AM	11/17/2011 12:00:00 AM		Permit Finaled	04/10/2013 12:00:00 AM	ADDRESS	34.05547	-118.26504	UPGRADE SERVICE TO AN EXISTING APARTMENT BUILDING AND REPLACING  PANELBOARDS IN  EACH OF THE 46 UNITS  AND NEW PANEL TO SUPPLY ELEVATORTHIS APPLICATION IS TO REPLACE  APPROVED PLANS THAT WERE LOST	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75784	16041-10000-19280	1625 N SCHRADER BLVD 1ST FLR	90028	13	148-5A187 241	5547015029	C4-2D	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	09/09/2016 12:00:00 AM		Permit Finaled	09/27/2016 12:00:00 AM	ADDRESS	34.10046	-118.33259	TI ON FIRST FLOOR. NEW LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75785	14041-10000-00307	7301 N MEDICAL CENTER DR STE 302	91307	12	186B097   829	2021014039	CR-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	Commercial			01/06/2014 12:00:00 AM			PC Approved	01/06/2014 12:00:00 AM	ADDRESS	34.20262	-118.62963	PLANCHECK FOR T24 ENERGY ONLY PER APPLICANTS REQUEST. PLAN CHECK ONLY. NOT A PATIENT CARE PER APPLICANT, ONLY CONSULTATION. 1276 SQFT, EMERGENCY LIGHTING.EXPRESS PERMIT PREVIOUSLY PULLED UNDER 13041-10000-35696	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75786	12041-10000-17829	4648 W HOLLYWOOD BLVD	90027	13	147B197   451	5542014006	C2-1	Central	Hollywood	East Hollywood		1913.02	Electrical	Electrical	Commercial			07/31/2012 12:00:00 AM			PC Approved	07/31/2012 12:00:00 AM	ADDRESS	34.10016	-118.29075	New 272 sq. ft. addition to an existing restaurant with an occupancy load of less than 99.  Load is less than 200Amps.  PLAN CHECK ONLY for Energy only, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75787	16041-10000-34511	11111 W SANTA MONICA BLVD STE 1000	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	12/29/2016 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC FOR ENERGY ONLY. NO CHANGE OF USE. T.I. OFFICE. HIGHRISE BUILDING. TOTAL AREA 3965 SQ FT. ADDED LOAD LESS THAN 400 A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75788	18041-10000-00550	721 E BROOKS AVE	90291	11	111B145  1266	4239007006	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	Commercial			01/05/2018 12:00:00 AM			PC Approved	01/09/2018 12:00:00 AM	ADDRESS	33.9972	-118.46561	Plan check for PV roof mounted system. System size: 3.8kW with 15 modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75789	16041-10001-23330	658 E VENICE BLVD	90291	11	108B145  1545	4237002006	M1-1-O	West Los Angeles	Venice	Venice		2738.00	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	33.98963	-118.46093	EXPEDITE PER APPLICANT REQUEST. ((((PV2 3PHASE SYSTEM. TOTAL SYSTEM SIZE 171KWAC. 686 MODULES AND 3 INVERTERS. SUBMIT PER MEHDI ZANDI	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75790	12041-10004-29913	12760 W MILLENNIUM BLDG A	90094	11	102B161  1115	4211013049	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01	Electrical	Electrical	Apartment			04/03/2015 12:00:00 AM	04/03/2015 12:00:00 AM		Permit Finaled	07/08/2015 12:00:00 AM	ADDRESS	33.97549	-118.41705	SUPPLEMENTAL TO APPROVED SET OF PLANS.  REVISIONS TO T24 LIGHTING AND INSTALLING 30 KVA TRANSFORMER.  DELTA D AND DELTA 37 REVISIONS ONLY.  AFFECTED SHEETS: E2.A.00E2.A.02E2.A.03E2.A.04E4.A.01E8.A.01<<<PLAN CHECK POWER AND ENERGY FOR NEW 4-STORY 100 UNIT APARTMENT COMPLEX. BUILDING 'A'. MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED. BUILDING LOCATED IN METHANE ZONE.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75791	10041-10000-08054	2200 W OLYMPIC BLVD Bld. A-Bld. B	90006	1	130-5A201 159	5136014007	C4-1	Central	Westlake	Pico Union		2095.10	Electrical	Electrical	Commercial			04/30/2010 12:00:00 AM			PC Info Complete	04/30/2010 12:00:00 AM	ADDRESS	34.05198	-118.28133	T.I. for an existing motel (Phase I).   Install general lighting outdoor and guestroom.  PC for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75792	10041-10000-12490	11666 W SHERMAN WAY	91605	2	183B169   145	2320001030	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.20	Electrical	Electrical	Commercial			07/02/2010 12:00:00 AM			PC Info Complete	10/06/2010 12:00:00 AM	ADDRESS	34.20103	-118.38536	Installing a Fire Alarm System for a medical office building. Plan check for Power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75793	13041-20001-32813	13345 N CONSTABLE AVE	91344	12	225B133    70	2601014025	RS-1, RS-1-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.03	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	12/19/2013 12:00:00 AM	ADDRESS	34.31272	-118.50599	((Expedite fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 15KW. 60 MODULES AND 2 INVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75794	12041-20002-27943	1901 S BUNDY DR	90025	11	123B149   330	4259018007	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM			PC Approved	10/15/2014 12:00:00 AM	ADDRESS	34.03497	-118.45709	Modifications to approved set. Add two lights on B2 parking level, reflect changes on Title 24 forms. Add 3 circuits for car wash area on the B2 parking level.[CUSTOMER BROUGHT CHECK. PLEASE RECALCULATE FEES BEFORE FINAL APPROVAL. NEW SERVICE? separate fire alarm variance filed 6/17/2013 mtNEW PARKING GARAGE. FULL POWER AND ENERGY PLAN CHECK. new parking facility. 833 car. 5 and half tier.  68621 sf below and 187934 sf above grade. 981 sf of attached restrooms and lockers. total SF = 257536 SF]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75795	12041-20000-05636	2049 S CENTURY PARK EAST S.2480	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM			PC Approved	03/12/2012 12:00:00 AM	ADDRESS	34.05903	-118.41293	S.2480 OFFICE T.I.ENERGY,Fire/ Life safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75796	19041-20000-26100	15950 W CHATSWORTH ST	91344	12	207B141   408	2668002017	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	Commercial			07/09/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	03/05/2020 12:00:00 AM	ADDRESS	34.26449	-118.48014	T24 PLAN CHECK FOR EXISTING COMMERCIAL CHURCH BUILDING. LIGHTS AND OUTLETS. TOTAL SQUARE FOOTAGE = 3815 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75797	19041-10000-10868	7600 N BALBOA BLVD 114	91406	6	186B133   186	2205008036	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM			PC Info Complete	07/24/2019 12:00:00 AM	ADDRESS	34.2087	-118.50093	POWER AND ENERGY PLAN CHECK FOR A TENANT IMPROVEMENT OF A RETAIL STORE TO A NEW 7 ELEVEN. SCOPE OF WORK INCLUDES NEW PANELS, CIRCUITS LIGHTING AND EQUIPMENT. TOTAL AFFECETED AREA IS 1905 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75798	14041-10000-28105	5455 W WILSHIRE BLVD Suite 1507	90036	4	135B181   903	5508010025	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	12/18/2014 12:00:00 AM	ADDRESS	34.06246	-118.34749	Title 24 plan check only.  Total area = 2,385 sq. ft.TI for existing commercial highrise.  Installation of lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75799	19041-20001-44289	5256 N MT ROYAL DR	90041	14	163-5A225 124	5669018027	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2019 12:00:00 AM			PC Approved	12/17/2019 12:00:00 AM	ADDRESS	34.14295	-118.20348	PLAN CHECK FOR NEW PV SYSTEM AND ESS. PV SYSTEM SIZE IS 18.48 KW/17.02 KW AC CEC. ESSS SIZE IS 26.4 KWH. SCOPE OF WORK CONSISTS OF (56) PV MODULES WITH MICROINVERTERS, A COMBINER BOX, (3) SUB PANELS, AND (2) BATTERIES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75800	19041-10000-01529	2841 N MONTCALM AVE	90046	4	156B177   363	2427014002	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2019 12:00:00 AM	01/28/2019 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.12301	-118.35572	PERMIT FEE IS $0.00 DUE TO AB1414PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 14.35KWdc / 11.4KWac. (41)MODULES-SOLARIA POWERXT-350R(41)OPTIMIZERS-SOLAREDGE P370(1)INVERTER-SOLAREDGE SE7600A-US(1)INVERTER-SOLAREDGE SE3800A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75801	11041-10000-17298	1075 S FAIRFAX AVE	90035	10	132B177   942	5086001018	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM			PC Approved	08/16/2011 12:00:00 AM	PIN	34.0561344	-118.3651032	T.I.  Exisitng 7-Eleven.  Replacing the existing light fixtures with LED fixtures within the retail area only.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75802	18041-10000-24547	250 S ROSSMORE AVE	90004	4	135B185    14	5515013001	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.06991	-118.32716	PC FOR (E) OFFICE TI FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS ONLY. EM. LIGHTS TO REMAIN. TOTAL AFFECTED AREA 3269 SQ.FT. B# 18016-10000-14263	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75803	19041-20000-13131	1305 S OCEAN FRONT WALK	90291	11	108A143   405	4226006002	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Apartment			04/10/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	01/23/2020 12:00:00 AM	ADDRESS	33.98831	-118.47476	SERVICE UPGRADE TO 800A SERVICE AND FIVE NEW 125A PANELS, EXISTING MOTOR AND PANEL LOADS PRESENT, A NEW 600A SWITCHBOARD, AND A NEW 800A SWITCHBOARDEXISTING APARTMENT BUILDING, 32 UNITS, 30 APARTMENT UNITS. AND 2 RETAIL UNITS ON THE GROUND FLOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75804	18041-20000-07174	9356 N LEMONA AVE	91343	7	198B149   174	2650034056	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1171.01	Electrical	Electrical	Commercial			02/27/2018 12:00:00 AM	03/06/2018 12:00:00 AM		Permit Finaled	10/18/2018 12:00:00 AM	ADDRESS	34.24086	-118.45871	New fire alarm system for 2 buildings.  Scope of this permit is for classroom building.  (101) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75805	13041-20000-01704	15963 W STRATHERN ST	91406	6	189B141    23	2206005021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1275.10	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM	01/31/2013 12:00:00 AM		Permit Finaled	05/01/2013 12:00:00 AM	ADDRESS	34.21581	-118.48145	Install new feeder and junction box to supply existing ATS switch.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75806	18041-10000-21852	17 E 23RD AVE	90291	11	105A145    26	4226015032	RD1.5-1-O	West Los Angeles	Venice	Venice		2739.02	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM	06/15/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	33.98358	-118.47006	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS A 5.20KWdc / 6.0KWac.(20)MODULES- LUMOS: LSX260-60M-C(1)INVERTER-SMA SUNNYBOY SB6000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75807	19041-20000-25873	10359 N MONOGRAM AVE	91344	12	204B137   133	2679012012	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2019 12:00:00 AM	07/08/2019 12:00:00 AM		Permit Finaled	07/24/2019 12:00:00 AM	ADDRESS	34.25912	-118.49257	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM ADDITION TO EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK INCLUDES 1 13.5KWH TESLA POWERWALL AND A 125A LOAD CENTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75808	13041-20001-22770	15276 W COBALT ST PV-1	91342	7	225B145   329	2501009010	RA-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2013 12:00:00 AM			PC Approved	09/13/2013 12:00:00 AM	ADDRESS	34.31127	-118.46495	EXPEDITE.PV-1. Plan check for microinverters. 34 microinverters for 7.31 kW total.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75809	10041-10000-00132	7320 N WOODLAKE AVE	91307	3	186B093   698	2021014052	QC1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Public Safety Only			01/05/2010 12:00:00 AM	01/05/2010 12:00:00 AM		Permit Finaled	02/22/2010 12:00:00 AM	ADDRESS	34.20263	-118.63189	Fire Alarm system upgrade. Adding some strop, smoke dectectors, replacing FACP, adding pull station inside three story office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75810	11041-10000-16961	9830 N LASAINE AVE	91325	12	201B129   122	2755013035	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/11/2011 12:00:00 AM			Corrections Issued	08/11/2011 12:00:00 AM	ADDRESS	34.24956	-118.51265	T.I.  New 8.385 KW roof mounted PV system.  Applicant used the standard plan for over the counter plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75811	19041-20000-02793	9911 W TOWER GROVE PL	90210	5	144B157   260	4356027013	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM			Reviewed by Supervisor	03/01/2019 12:00:00 AM	ADDRESS	34.09112	-118.42322	Plan check for power only Single Family Dwelling 800A 120/208Volt 3 story building. B#16010-30000-04125Plan check only, permit pulled under Building Application Number: 16010-30000-04125	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75812	13041-20000-29527	6611 N VALJEAN AVE	91406	6	180B137   263	2233031044	M1-1, P-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1276.05	Electrical	Electrical	Commercial			10/22/2013 12:00:00 AM	10/30/2013 12:00:00 AM		Permit Finaled	01/02/2014 12:00:00 AM	ADDRESS	34.19064	-118.48601	"PV2 COMMERCIAL INSTALLATION. TOTAL SYSTEM SIZE 33KW. 132 MODULES AND 3 INVERTERS. ""$0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75813	15041-10000-12879	4334 S DEGNAN BLVD	90008	10	114B185  1143	5024019008	[Q]C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2343.00	Electrical	Electrical	Commercial			04/29/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	02/16/2016 12:00:00 AM	ADDRESS	34.00494	-118.33125	TI-24 TO AN (E) 2 STORY BUILDING. CONVERTING TO LED LIGHTING. TOTAL SQ. FT. 3211	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75814	13041-10000-24456	12811 W MILLENNIUM	90094	11	102B161  1220	4211033039	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			09/06/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	08/10/2015 12:00:00 AM	ADDRESS	33.97537	-118.41814	New 100 A service for lighting and receptacles in Playa Vista PVCC Park.  Methane zone.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75815	18041-30000-37461	350 S GRAND AVE 35TH FL.	90071	14	130-5A211  39	5149010265	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	08/09/2019 12:00:00 AM		Permit Finaled	01/04/2023 12:00:00 AM	ADDRESS	34.05173	-118.2522	PLAN CHECK FOR T24 ONLY, TI ON (E) OFFICE SPACES ON 35TH FLOOR, TOTAL AREA: 2215 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75816	10041-20000-03923	13501 W OSBORNE ST	91331	6	198B157   204	2621022012	RA-1	North Valley	Arleta - Pacoima	Arleta		1190.00	Electrical	Electrical	Commercial			03/04/2010 12:00:00 AM	03/04/2010 12:00:00 AM		Permit Finaled	05/24/2010 12:00:00 AM	ADDRESS	34.24148	-118.42719	Fire Alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75817	16041-10000-31879	400 W 30TH ST	90007	9	120A203    86	5122018033	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.02393	-118.27577	TENANT IMPROVEMENT; AT SERVER ROOM ONLY. TITLE 24 FOR EXISTING LOW-RISE BUILDING.TOTAL SQ. FT. = 315	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75818	10041-20000-25715	4600 W SPERRY ST	90039	4	165B201   177	5593007004	M3-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			12/29/2010 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Closed	04/18/2012 12:00:00 AM	ADDRESS	34.14823	-118.27596	New roof mounted 10.5 kw AC module P.V. system for commercial building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75819	16041-20000-13123	20324 W AETNA ST	91367	3	177B113   187	2149009003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.17868	-118.57628	Plan check for a PV1 roof-mounted PV system. System size is 10.2 kWac and consists of (2) inverters, (38) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75820	07041-10004-12960	1724 N HIGHLAND AVE	90028	13	148-5A185  63	5547011023	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/03/2010 12:00:00 AM			PC Approved	03/26/2010 12:00:00 AM	ADDRESS	34.10238	-118.3385	Plan check only. Plan check for revision to approved plans.  Delta 8 indicated on plan to reflect field changes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75821	17041-10000-26088	1755 W CHANDELEUR DR	90732	15	015B189    87	7559024002	R1-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2964.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Closed	05/17/2018 12:00:00 AM	ADDRESS	33.73912	-118.31461	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM - SYSTEM SIZE (5.0KVA) WITH BATTERY BACK UP SYSTEM. SYSTEM CONSIST OF 1 INVERTER (SOLAREDGE 5000A) WITH 20 MODULES (SOLARCITY) AND POWER OPTIMIZERS(P400).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75822	16041-20000-37554	20715 W SCHOOLCRAFT ST	91306	3	183B109   587	2137025009	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1340.02	Electrical	Electrical	1 or 2 Family Dwelling			10/24/2016 12:00:00 AM	10/24/2016 12:00:00 AM		Permit Finaled	06/06/2017 12:00:00 AM	ADDRESS	34.19675	-118.58455	pv1install roof mounted pv system sized 6kw interconnected with msp. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75823	17041-10000-11104	666 N LAVETA TER	90026	1	138A209   292	5405007900	RD2-1VL-HPOZ	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1975.00	Electrical	Electrical	Commercial			04/06/2017 12:00:00 AM	04/06/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	34.07102	-118.25745	PC FOR ENERGY ONLY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  8240 SQ FT.  OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75824	19041-10000-41850	201 N CARMELINA AVE	90049	11	132B141   172	4405009008	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			10/15/2019 12:00:00 AM			Reviewed by Supervisor	10/23/2019 12:00:00 AM	ADDRESS	34.06058	-118.48418	PLAN CHECK FOR POWER ONLY FOR  REMODEL OF EXISTING SINGLE FAMILY DWELLINGW/ATTACHED GARAGE.  ADDITION OF A NEW 800 AMP SERVICE. 120/208 3PHASE 4WIRE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75825	15041-10001-37711	5235 N TOPEKA DR	91356	3	171B121   300	2163024002	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2015 12:00:00 AM			PC Approved	12/02/2015 12:00:00 AM	ADDRESS	34.1656	-118.54667	EXPEDITED RSES PLAN CHECK PER APPLLICANT REQUEST.<<<PV1, INSTALL 10.80 KW DC  ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (40) MODULES:  MITSIBISHI PV-MLE270HD(1) INVERTER: SOLAREDGE SE11400A-US>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75826	10041-20000-13229	6026 N WHITSETT AVE	91606	2	177B165   614	2333010005	R1-1, R3-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	10/21/2010 12:00:00 AM		Permit Finaled	11/29/2011 12:00:00 AM	ADDRESS	34.18031	-118.40501	PLAN CHECK POWER AND ENERGY  3-STORY 17-UNIT APT. BLDG. OVER TYPE I-A BASEMENT GARAGE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75827	18041-20000-10066	42 N HALDEMAN ROAD	90402	11	126B129   653	4409028009	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Closed	05/08/2024 12:00:00 AM	ADDRESS	34.03984	-118.51316	pv1install roof mounted pv system sized 7.3kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75828	14041-20005-03004	7343 N RESEDA BLVD	91335	3	186B125   756	2118015003	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			08/29/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.20424	-118.53632	8/29/2018changes to an approved set of plans.  changes to the feeder voltage drops.  this is plan check only.   ((((8/2/2018changes to an approved set of plans.  changes to reflect field conditions.  all changes are clouded and noted.  This is plan check only.))))((((New Mix-use - 2,280 sf Retail  & 40 Unit  Apt. Bldg. With 1st and 2nd floor private garage/retail and 3rd/4th/5th/6th floor 40-units Apt. bldg with bonus dencity.  New 1600A service, switchboard, panels, and branch circuit.  Plan check for power and energy.Note: Variance to separate fire alarm is submitted.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75829	18041-20000-35198	10827-10836 W RIVERTON CT	91602	2	168B173  1172	2421035001	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Issued	09/14/2018 12:00:00 AM	ADDRESS	34.15421	-118.3667	new 1200 amp service to feed multi SFDs.  plan check for power only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75830	18041-10003-02140	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM			PC Approved	10/09/2019 12:00:00 AM	ADDRESS	33.94221	-118.40701	***Replacment of the lost plans***<<<SUPPLEMENTAL FOR CHANGES TO APPROVED SET, ADDITION OF 1403 SQFT, AND 22 NEW BRANCH CIRCUITS, NEW TOTAL SQFT = 34683>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75831	16041-10000-30502	2738 W OLYMPIC BLVD	90006	10	129B197   217	5078011024	C2-1, P-1	Central	Wilshire	Pico Union		2133.20	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	34.05244	-118.29309	Energy plan check for change of use from restaurant to retail store T.I Scope include new lighting and receptacles; Total area is 598 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75832	19041-10000-14105	10250 W SANTA MONICA BLVD 2360	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	06/26/2019 12:00:00 AM		Issued	06/26/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	Full PC for First T.I. (First time tenant). space is served by 200A,480V/277, 3PH,4wire. Area scope 3,367SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75833	19041-20000-22227	22135 W ROSCOE BLVD LOT #31	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/11/2019 12:00:00 AM	06/11/2019 12:00:00 AM		Permit Finaled	06/25/2020 12:00:00 AM	ADDRESS	34.21979	-118.6095	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON NEW SFD TRACT HOME LOT 31.SYSTEM SIZE IS 2.17KW DC/1.68 KW AC. SCOPE OF WORK INCLUDES (7) MISSION SOLAR PV MODULES WITH ENPHASE IQ7PLUS MICROINVERTERS AND A COMBINER BOX.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75834	14041-20000-01504	11300 W SUNBURST ST	91342	7	213B173   308	2530034016	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2014 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.27862	-118.37739	PV1 TRANSFORMERLESS SYSTEM. USING OPTIMIZERS. TOTAL SYSTEM SIZE 3KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75835	16041-10001-11365	1301 S MAIN ST	90015	14	124-5A207  94	5133010016	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM			PC Approved	09/19/2016 12:00:00 AM	ADDRESS	34.0365	-118.26067	PC SUPP. CHANGES INCLUDES CHANGE OF EMERGENCY LUMINAIRE TO BUG EYE AND PHOTOMETRIC ANALYSIS. PERIMT UNDER MASTER APPLICATION.**********************************************************************************(TI) CHANGE OF USE FROM RETAIL TO OFFICE AT 2nd FLOOR LEVEL.  PC FOR T-24 ONLY. TOTAL AREA: 8,677 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75836	16041-10000-21258	300 WORLD WAY Terminal#3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/16/2016 12:00:00 AM	06/28/2016 12:00:00 AM		Permit Finaled	08/30/2016 12:00:00 AM	ADDRESS	33.94502	-118.40714	PC FOR ENERGY ONLY. NEW AHU SYSTEM; REPLACE TILE CEILING IN (2) OFFICES AND HARDLID IN RESTROOMS IN TERMINAL 3 IN LEVEL 2. NO NEW SF ADDED TOTAL AREA 642 SQ FT.B# 16016-10000-02533	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75837	19041-20000-20184	6860 N COSTELLO AVE	91405	2	183B153   894	2216016012	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.1958	-118.43767	Plan check for PV roof mounted system, PV system size: 17.64KW DC, 15.5KW AC with 49 PV Modules and 2 inverters(7.6KW) PV1.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75838	17041-30000-02284	3000 S ROBERTSON BLVD 280	90034	10	123B169   884	4311033015	[Q]C4-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2697.00	Electrical	Electrical	Commercial			01/24/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	34.03242	-118.39001	Title 24 plan check.  T.I. to existing low rise commercial office building.  Unit # 208.  (3,600 sq ft)Building permit #16016-30000-31223	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75839	17041-10000-09058	11216 N NORRIS AVE	91331	7	210B157   163	2534006009	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2017 12:00:00 AM	03/21/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.27384	-118.41969	PV , INSTALLATION OF A 6.0 KWdc/ 5.0KWac ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MODULES: HANWHA Q CELL (1) INVERTER: SOLAREDGE SE5000	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75840	12041-20000-27779	630 W 6TH ST 1st floor	90017	9	129A209   260	5144005***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/19/2012 12:00:00 AM	01/30/2013 12:00:00 AM		Permit Finaled	03/11/2013 12:00:00 AM	ADDRESS	34.04916	-118.25624	Change to lighting and receptacles in an existing restaurant in a high-rise building on the first floor.  Load is less than 400 amps and occupancy load is greater than 99.  Plan check for power and energy.  All Emergency lighting to remain existing per applicant.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75841	14041-20000-18049	24566 W EILAT ST	91367	3	177B085   602	2032022003	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	1 or 2 Family Dwelling			07/03/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/31/2014 12:00:00 AM	ADDRESS	34.17736	-118.66023	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(23) TRINA SOLAR TSM-255(1) POWER ONE TRANSFORMERLESS INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75842	18041-10000-35042	800 S ALVARADO ST	90057	1	132A203   260	5141020017	C2-1	Central	Westlake	Westlake South		2094.02	Electrical	Electrical	Commercial			09/13/2018 12:00:00 AM	04/09/2019 12:00:00 AM		Permit Finaled	10/01/2019 12:00:00 AM	ADDRESS	34.05467	-118.27777	installation of exterior luminaires for parking lot and facadePLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75843	17041-20000-05488	6328 N HAZELTINE AVE 1-7	91401	2	177B153    33	2239001005	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Apartment			02/21/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	01/10/2020 12:00:00 AM	ADDRESS	34.18558	-118.43981	7 unit apartment over basement parking garage.  600A 120/240V 1ph-3w service.  Plan check for power and energy.Building permit filed under 15010-20000-01571	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75844	14041-10000-35783	7135 N SEPULVEDA BLVD	91406	6	183B145   113	2222029006	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			12/29/2014 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	PIN	34.20031329	-118.46682066	ALTERATIONS FOR A WABA GRILL RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75845	12041-10000-16077	8500 W BURTON WAY	90048	5	138B173  1321	4334016086	(T)(Q)C2-2D-O	Central	Wilshire	Mid City West		2148.00, 2149.00	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	07/23/2012 12:00:00 AM		Permit Finaled	02/22/2013 12:00:00 AM	ADDRESS	34.07095	-118.37677	Plan check for installation of new roof mounted 43.3KW AC CEC photovoltaic system. Apartment building..	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75846	14041-10001-08009	13950 W GARBER ST	91331	6	198B153    29	2642013019	R1-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2014 12:00:00 AM			PC Approved	05/15/2014 12:00:00 AM	ADDRESS	34.24334	-118.43699	(((EXPEDITE FEES)))PV1 MICROINVERTER SYSTEM. TOTAL SYSTEM SIZE 4.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75847	14041-10000-10247	1015 S CROCKER ST # R31	90021	14	124-5A211 347	5132030***	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/18/2014 12:00:00 AM	04/18/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.0345	-118.2508	T24,REMOVE HID LIGHTING FIXTURES AND REPLACE WITH NEW FUORESCENT FIXTURES. TOTAL AREA 1017 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75848	15041-20000-14266	20519 W LONDELIUS ST	91306	3	195B109   230	2780013008	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Expired	06/16/2017 12:00:00 AM	ADDRESS	34.22919	-118.58041	Plan check for PV roof mounted system 12.0kWac system with 58 modules and 2 inverters(6.0kW) and 4 stringsNote: Permit fee is $0.00 due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75849	10041-10002-15139	1511 W FRANCISCO ST Bldg B-suite D	90501	15	057B193    25	7351021800	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			02/13/2012 12:00:00 AM	02/21/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	33.85075	-118.30473	Revised drawings to show changes only on the second floor- new panelboard and circuits required for the construction of new offices and conference room on the second floor; no new luminaires but some luminaires have been re arranged to accomodate the new walls .New building.  New service, panels, and branch circuits.  Plan check for energy and power.  NOTE: refer to 10041-10K-15136 for Bldg A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75850	18041-10000-47980	1945 W BLAKE AVE	90039	13	148-5A213 317	5442010028	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			12/18/2018 12:00:00 AM	12/26/2018 12:00:00 AM		Permit Finaled	06/09/2020 12:00:00 AM	ADDRESS	34.09967	-118.24376	TI IN AN EXISTING COMMERCIAL BUILDING. PLAN CHECK FOR POWER & ENERGY. 6709 SQR FT.BULDING PERMIT: 18020-10000-03016	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75851	17041-10000-29242	"3109 W OLYMPIC BLVD Space ""D"""	90006	10	129B193   270	5080024026	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2132.01	Electrical	Electrical	Commercial			08/17/2017 12:00:00 AM	09/08/2017 12:00:00 AM		Permit Finaled	10/26/2017 12:00:00 AM	ADDRESS	34.05277	-118.3036	PC for T24 only for restuarant TI. Total affected area is 849 sqft. Building #17016-30000-21728. Instlling new panel, new lights, receptacels and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75852	12041-20000-20697	19850 S MAGELLAN DR	90502	15	057B197    56	7351034065	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/31/2012 12:00:00 AM	02/06/2013 12:00:00 AM		Permit Finaled	07/16/2013 12:00:00 AM	ADDRESS	33.85035	-118.29277	Plan check for power and energy. TI to an industrial warehouse. Not a methane zone. 26370 sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75853	15041-20000-43546	1074 N AVENUE 51	90042	1	154-5A225 247	5478013017	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.10	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	03/01/2016 12:00:00 AM	ADDRESS	34.11799	-118.20549	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (18)MODULES-SOLARWORLD SW 285 MONO(1)INVERTER-SUNNYBOY SMA SB5000TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75854	15041-10000-00438	4158 N VENTURA CANYON AVE	91423	4	165B157   921	2373011015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2015 12:00:00 AM	01/07/2015 12:00:00 AM		Permit Finaled	01/27/2015 12:00:00 AM	ADDRESS	34.14618	-118.42927	PV1 4.3KW roof-mounted system with (18) Solar World SW280 modules and Enphase M250 microinverters. Note. plan chevk over counter per customer request.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75855	18041-10000-41380	6245 W WILSHIRE BLVD #101, #102-#103	90048	5	135B177   481	5510027065	[Q]C4-2D-O	Central	Wilshire	Mid City West		2147.00	Electrical	Electrical	Commercial			10/29/2018 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	08/28/2019 12:00:00 AM	ADDRESS	34.06356	-118.36478	TITLE 24 PLAN CHECK ONLY FOR TENANT IMPROVEMENT: CHANGE OF USE, RETAIL TO FUTURE RESTAURANT. ACCESSIBLE RESTROOMS, TOTAL EFFECTED AREA 1169.87 SQ/FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75856	15041-20001-34219	13087 W RANGOON ST	91331	6	195B161   137	2628008012	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM			PC Approved	10/20/2015 12:00:00 AM	ADDRESS	34.23459	-118.4178	**Expedite FeePV1, roof mtd. solar system 5.5 kW transformerless . (22) modules: Solarworld SW250 Poly, (1) inverter: Fronius Primo 5.0-1	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75857	12041-20000-28196	11017 N BAIRD AVE	91326	12	210B125   533	2717013006	RE11-1	North Valley	Northridge	Northridge West		1112.03	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2012 12:00:00 AM	12/13/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.27027	-118.53747	PV-1. Plan check for PV system. Enphase microinverters. 6.02kW AC, 6.44kW DC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75858	17041-20000-16017	10563 W ASHTON AVE	90024	5	132B157    54	4326002017	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			05/12/2017 12:00:00 AM	04/24/2018 12:00:00 AM		Issued	04/24/2018 12:00:00 AM	ADDRESS	34.06161	-118.43204	PLANCHECK FOR POWER AND ENERGY. 3 STORY 3 -UNIT APT WITH SUBTERRANEAN GARAGE.fire alarm variance has been submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75859	17041-20001-08019	3435 N ARDSLEY PL	91436	5	159B133   247	2292022015	(T)(Q)RE40-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2017 12:00:00 AM			PC Approved	04/03/2017 12:00:00 AM	PIN	34.13114578	-118.50309081	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on SFD. Interconnect with a 400A MSP.13.23kW ungrounded system. (49) EnPhase S280 microinverters. (49) 320W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75860	17041-10000-33849	900 N NORTH BROADWAY F-1050	90012	1	135A215   238	5414013901	C2-2	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	10/20/2017 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.06408	-118.23726	PC for power and energy for first time tenant in suite F-#1050. Total area of 1847sqft. Installing two new panels, 1 new 75kVA xfrm, new circuits, equipment. Building 17016-10000-27546	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75861	17041-20000-46575	1014 E MANCHESTER AVE A,B,C,D,E	90001	9	097-5A209 264	6042023030	CM-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM	01/03/2018 12:00:00 AM		Permit Finaled	04/16/2018 12:00:00 AM	ADDRESS	33.96	-118.25717	Plan check for energy only. TI to (E) retail units A, B, C, D, E, and F. New lighting (incl. emergency) - 6,570sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75862	11041-10000-08951	137 N SOTO ST 1-20	90033	14	127-5A223  76	5183005019	[Q]R4-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.20	Electrical	Electrical	Apartment			05/03/2011 12:00:00 AM	06/06/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.04482	-118.20939	NEW FIRE ALARM SYSTEM FOR NEW APARTMENT BUILDINGS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75863	13041-10000-31271	6922 W HOLLYWOOD BLVD 12TH FLR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	11/07/2013 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLAN CHECK AND PERMIT FOR TITLE 24 PART 6 WORK TO EXISTING OFFICES; TENANT IMPROVEMENTTO INSTALL NEW LIGHTS AND RECEPTACLES IN HIGH RISE BUILDING. SCOPE OF WORK < 400A. NO EMERGENCY CKT WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75864	13041-10000-21107	12057 W WILSHIRE BLVD	90049	11	126B145    66	4265016027	[Q]C4-1L-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			08/07/2013 12:00:00 AM			PC Approved	08/07/2013 12:00:00 AM	PIN	34.04495689	-118.46700701	permit to be pulled at EPC counter only. PC for energy only.   emergency lighting is existing and no work being done on it. less than 400A per applicant. TI FOR INTERIOR REMODEL OF (E) RALPHS STORE, REMOVAL and replacement of sales area fixtures with all associated electrical items. remodel (E) interior lighting. 26,064SF. but only new lighting is (N) susp track lights mtd 11' AFF TR-16 at produce, floral and bakery. TR-18 at liquor. (other lights are existing)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75865	13041-20000-16642	10974 W VENTURA BLVD	91604	2	162B173   555	2378007014	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			06/24/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Permit Finaled	09/30/2013 12:00:00 AM	ADDRESS	34.14011	-118.3698	EXISTING GASOLINE STATION. 76. CONSTRUCTION OF AIR SPARGE SYSTEM. CLASSIFIED FOR HAZARDOUS MATERIALS. PC FOR POWER SYSTEM ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75866	19041-10000-07170	1710 N CHEROKEE AVE	90028	13	148-5A185  58	5547004901	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	04/30/2019 12:00:00 AM	ADDRESS	34.10235	-118.33462	RMEOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75867	19041-10000-34919	1200 S CABRILLO AVE	90731	15	015B197  1440	7454022005	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2969.02	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM	09/04/2020 12:00:00 AM		Permit Finaled	01/11/2021 12:00:00 AM	ADDRESS	33.73315	-118.29441	FULL PC FOR POWER AND ENERGY. SCOPE OF WORK CONSISTS OF (2) PANELS, NO NEW LOADS, RELOCATION OF EQUIPMENT, NEW LIGHTS AND NEW RECEPTACLES USING EXISTING CIRCUITS. T24 INCLUDED. TOTAL SQUARE FOOTAGE = 1780 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75868	16041-10000-02487	3900 W 6TH ST	90005	10	135B193   885	5503030001	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Commercial			01/22/2016 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	PIN	34.06325314	-118.30807759	PC FOR POWER AND ENERGY. TI FOR RESTURANT. NO CHANGE OF USE, 2-STORY WITH ONE LEVEL BASEMENT, SMT LA RESTURANT. ADDING 6 NEW 200A PANELS AND TWO 45 KVA TRANSFORMER  TOTAL AREA 13660 SQ (INDOOR AND OUTDOOR).B# 15016-10000-25358	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75869	17041-20000-25694	1010 W PACIFIC COAST HWY	90744	15	036B201   779	7415004036	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2943.02	Electrical	Electrical	Commercial			07/28/2017 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	33.79034	-118.27548	Plan check for energy only. TI to existing drive-through restaurant (Jack in the Box).New lighting (incl. emergency): indoor-2,669sqft; outdoor-25,829sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75870	13041-20000-27433	4833 N DENNY AVE	91601	2	168B177   398	2421008005	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.02	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2013 12:00:00 AM	10/03/2013 12:00:00 AM		Permit Finaled	11/22/2013 12:00:00 AM	ADDRESS	34.15859	-118.36493	PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. 18 MODULES AND 1 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75871	19041-10000-29210	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	PPSP	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			07/29/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	02/11/2021 12:00:00 AM	ADDRESS	34.08363	-118.32191	Power plan check for HVAC equipment replacement. Scope includes (1) medium voltage (5kv) transformer and other motors through out the floor plan on stage 25  through 28.License # P 035757	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75872	15041-20001-27275	22242 W ROMAR ST	91311	12	204B101   378	2745011029	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	1 or 2 Family Dwelling			08/20/2015 12:00:00 AM			PC Approved	09/02/2015 12:00:00 AM	ADDRESS	34.25477	-118.6121	Expedite fees.  Installation of new roof moutned solar PV array.  Total system size = 12.82 kW.  Microinverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75873	17041-10000-41690	5028 N CARTWRIGHT AVE	91601	2	171B177  1128	2419014007	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1255.01	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM	11/28/2017 12:00:00 AM		Permit Finaled	01/23/2018 12:00:00 AM	ADDRESS	34.16207	-118.36357	PC for 6.6kW rooftop solar with backup battery. Installing 22 modules with optimizers, one multimode inverter and 5kW battery backup (battery under suplemental 17041-10002-41690).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75874	19041-10000-02329	767 S ALAMEDA ST #250,#270-,#210	90021	14	124-5A215  30	5146009008	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Info Complete	01/18/2019 12:00:00 AM	ADDRESS	34.03474	-118.24063	PC FOR T-24 ONLY CHANGE OF USE TO OFFICE AREA  14812 SQ.FT.SCOPE INCLUDES NEW LIGHTING AND RECEPTACLE TO SUITES 210,250 AND 270BULDING PERMIT: 18016-10000-39891	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75875	11041-20000-24040	12410 N LONGACRE AVE	91344	12	219B125   128	2601075064	RE20-1-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			11/09/2011 12:00:00 AM	12/06/2011 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	ADDRESS	34.29518	-118.53508	New 8.46KW ground mounted solar system for a single family residence. Methane Buffer zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75876	14041-20000-08408	6326 N LINDLEY AVE	91335	5	177B125   148	2123022001	RA-1	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	Commercial			03/28/2014 12:00:00 AM	04/16/2014 12:00:00 AM		Permit Finaled	05/05/2014 12:00:00 AM	PIN	34.18466698	-118.52697308	Roof mounted PV system on child care with size 7.2 KWdc.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75877	11041-10003-13633	5115 W WILSHIRE BLVD Suite B&C	90036	4	135B181   918	5507021035	[T][Q]C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			03/06/2012 12:00:00 AM			PC Approved	03/06/2012 12:00:00 AM	ADDRESS	34.06233	-118.34134	REVISIONS TO APPROVED SET OF PLANS : CHANGES TO SOME LUMINAIRES WITH LESS WATTAGE INSTALLED; ADDED RECEPTACLES; MOVED LOADS FROM ONE PANELBOARD TO THE OTHER PANELBOARD. PLAN CHK ONLY.I.  Exisitng restaraunt in suite # B & C on the first floor of a six story, Low Rise building. (Changes to Approved Plans).  Remodeling of light fixtures.  Plan check is for T-24 Energy only. Complete Plan Check may be required, subject to field inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75878	11041-10000-18159	8701 N SAN FERNANDO ROAD	91352	6	195B169   525	2631034027	M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.20	Electrical	Electrical	Public Safety Only			08/25/2011 12:00:00 AM	09/07/2011 12:00:00 AM		Permit Finaled	09/23/2011 12:00:00 AM	ADDRESS	34.22749	-118.38141	Install  a sprinkler monitoring system in the building.  Includes a FACP and 6 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75879	13041-10001-27144	18815 W STARE ST	91324	12	204B121   497	2729016001	RE11-1	North Valley	Northridge	Northridge West		1112.05	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.25269	-118.54316	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75880	16041-20000-19187	7054 N VAN NOORD AVE	91605	2	183B161   292	2327018012	R1-1	South Valley	North Hollywood - Valley Village	North Hollywood West		1234.20	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2016 12:00:00 AM	06/17/2016 12:00:00 AM		Permit Finaled	06/30/2016 12:00:00 AM	ADDRESS	34.19917	-118.4148	Plan check for the addition of a PV1 roof-mounted PV system onto an existing system. Addition system size is 3 kWac for a total system size of 6.6 kWac. Addition consists of (1) inverter, (1) load center, and (10) modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75881	18041-20000-36933	1815 S MESA ST LOT 15	90731	15	012B201   579	7456029026	[Q]R3-1XL	Harbor	San Pedro	Coastal San Pedro		2971.20	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	11/06/2019 12:00:00 AM	ADDRESS	33.72751	-118.28612	Plan check for PV roof mounted system, system size: 3.02KW with 9 AC Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75882	18041-20001-03166	6033 W CENTURY BLVD 100	90045	11	090B169    17	4124030901	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/15/2018 12:00:00 AM	02/15/2018 12:00:00 AM		Permit Finaled	07/16/2019 12:00:00 AM	ADDRESS	33.94572	-118.38954	02/15/2018 Plan check for Title 24 only. Project site is a suite on the ground floor of an existing commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,089 sq. ft.Note: Building application has been generated under 17016-10000-35206*****Previous Work Description*****New outlets and furniture feeds.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75883	09041-10001-21093	9433 N RESEDA BLVD	91324	12	198B125   125	2763035003	C2-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			08/24/2012 12:00:00 AM			PC Info Complete	09/28/2012 12:00:00 AM	ADDRESS	34.242	-118.53628	((((((((((((((((((((((((((((  8-24-12   Changes made to previously approved set, changes to title 24, panel loads , equipment and fixtures.))))))))))))))))))))))))  New service and remodel for an existing building.  Power and emergy.customer requested to be removed from system record so he can get c of o  this plan check was done under different permit and this is no longer needed  from CID contracting Joe wedding	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75884	18041-10004-02129	500 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/12/2019 12:00:00 AM			PC Approved	04/12/2019 12:00:00 AM	ADDRESS	33.94248	-118.40461	T-24 SUPPL PC. CHANGE TITLED RFI-335. SCOPE INCLUDE REPLACING 45 FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75885	14041-10001-24973	1940 S CREST DR	90034	5	126B169   345	4302008035	R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/21/2014 12:00:00 AM	ADDRESS	34.04353	-118.38841	EXPEDITED RSES PLAN CHECK PER  APPLICANT REQUEST.{{PV1, INSTALL 7.65 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(30) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75886	10041-10000-24667	5223 W CENTURY BLVD	90045	11	090B173    89	4128017030	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2774.00	Electrical	Electrical	Commercial			12/10/2010 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	12/09/2011 12:00:00 AM	ADDRESS	33.94559	-118.37075	TI IN AN EXISTING COMMERCIAL BUILDING.  <<<<INSTALL FACADE OUTDOOR LIGHTING ONLY>>>>.  PLAN CHECK IS FOR T-24 ENERGY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75887	18041-10000-08556	9301 N TAMPA AVE #066	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/08/2018 12:00:00 AM	03/14/2018 12:00:00 AM		Permit Closed	07/05/2018 12:00:00 AM	ADDRESS	34.2392	-118.55379	TENANT IMPROVEMENT WORK FOR NEW FOOT AND MASSAGE SPA IN SHOPPING CENTER; CHANGE OF USE FROM RETAIL TO FOOT MASSAGE PARLORPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75888	14041-10002-35268	889 S FRANCISCO ST	90017	14	129A207   100	5144023042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			06/30/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.04769	-118.26404	Changes to approved set of plans. All clouded and deltas are changes to the previously approved set on single line diagram. Refer to clouded areas. (((Plan check for power and lighting. Core-and-shell for a new 38-story residential building.  Service size is (2) 1,200 amp services.308 residencies on 32 floors with 6-story podium, pool deck, and 7 levels of parking. Total lighting area = 331,642 sq. ft. Building application submitted prior to July 1st, 2014. Title 24 forms reflect this and are the 2008 Nonresidential Compliance Forms. Building application is filed under 13010-10000-03024.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75889	19041-20000-50827	470 N WILTON PL	90004	4	141B193  1230	5522017028	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			12/10/2019 12:00:00 AM			PC Info Complete	10/02/2020 12:00:00 AM	PIN	34.07998854	-118.31333332	Plan check for power and energy for 800 Service. Total area: 18,8100 sq ft. #18010-20000-04312**************************Building Work description: 5 STORY 13 UNIT APT WITH SUBTERRANIAN GARAGE PER AFFORDABLE HOUSING 12.22.A.25. <BUILDING SHALL BE FULLY SPRINKLERED>***************************************	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75890	18041-20000-39977	17337 W RAYEN ST	91325	12	195B129   211	2768018003	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2018 12:00:00 AM	10/18/2018 12:00:00 AM		Permit Finaled	11/28/2018 12:00:00 AM	ADDRESS	34.2323	-118.51268	Plan check for PV roof mounted system, system size: 6.96KW AC with 24 PV modules and 24 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75891	18041-20000-21506	4402 N LEDGE AVE	91602	4	165B177   353	2424005014	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/08/2018 12:00:00 AM		Permit Finaled	07/31/2018 12:00:00 AM	ADDRESS	34.1506	-118.35694	Plan check for PV roof mounted system. System size: 12.8kWac with 42 modules  and 2 inverters(7.6kW and 5.2kW) connected to MSP	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75892	16041-20000-17291	18451 W SUNNY LANE CT	91356	3	171B125   199	2161021048	R1-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.16716	-118.53531	PV1.  Install 11.1 kW roof-mounted PV system.  (38) modules with (2) central transformerless inverters rated at 7 kW and 3.8 kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75893	17041-20000-33520	5808 W SUNSET BLVD 5th fl	90028	13	147A191    79	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/07/2017 12:00:00 AM	ADDRESS	34.09782	-118.31646	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 882 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75894	16041-10000-34551	744 S SAN JULIAN ST	90014	14	126A211   186	5145008018	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.04013	-118.2485	PC for energy only. Remove HID fixture and replace with new LED fixture. Total sqft = 7365	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75895	16041-20001-45798	1724 N ORANGE GROVE AVE	90046	4	147B177   224	5551008016	R1-1	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/30/2016 12:00:00 AM			PC Approved	01/09/2017 12:00:00 AM	ADDRESS	34.10231	-118.36034	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 5.2 kWac and consists of (15) AC PV modules and (1) load center. System is interconnecting with a 400-amp service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75896	16041-20000-40944	10254 ANGEL LANE	91331	7	204B165   427	2537004037	(Q)RD3-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2016 12:00:00 AM	11/18/2016 12:00:00 AM		Permit Finaled	02/14/2018 12:00:00 AM	PIN	34.25704136	-118.40448305	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter and (12) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75897	14041-20000-22840	555 E RAMIREZ ST 2ND FLOOR	90012	14	132A217   238	5409021900	PF-1XL	Central	Central City North			2060.20	Electrical	Electrical	Commercial			08/21/2014 12:00:00 AM	09/22/2014 12:00:00 AM		Permit Finaled	01/22/2015 12:00:00 AM	ADDRESS	34.05425	-118.2309	PC FOR 2ND FLOOR TI. NEW LIGHTING. NEW EQUIPMENT. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75898	12041-10000-09679	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010		Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM	08/02/2012 12:00:00 AM		Permit Expired	09/02/2014 12:00:00 AM	ADDRESS	33.77884	-118.29327	Plan check for installations two transformers and two temp office trailers. Installation not in hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75899	19041-20000-31621	3672 S JASMINE AVE 1-17	90034	5	120B165   936	4313003029	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.06	Electrical	Electrical	Apartment			08/13/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	05/24/2022 12:00:00 AM	ADDRESS	34.02438	-118.40378	PLAN CHECK FOR NEW FIRE ALARM SYSTEM FOR NEW 5-STORY 17-UNIT APARTMENT BUILDING. SCOPE OF WORK INCLUDES (116) FA AND A FA PANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75900	16041-10000-29420	1025 N MCCADDEN PL	90038	4	144B185   866	5532027002	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	12/06/2016 12:00:00 AM	ADDRESS	34.08974	-118.33756	PC for energy only. Tenant improvement to office and industrial storage areas of existing building.  Total area is 11,785 sq ft. Building permit #16016-30000-05165.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75901	16041-20002-11402	18334 W MALDEN ST	91325	12	192B125   203	2786007004	(T)(Q)R3-1, R1-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	Apartment			03/15/2019 12:00:00 AM			PC Approved	05/20/2019 12:00:00 AM	PIN	34.22512205	-118.53292311	"3/15/2019changes to an approved set of plans.  changes noted delta 5 only.  changes to light fixture types and energy calculations.this is plan check only.  ((((Revisions to approved set.  Review and approval for delta E2 and E3 revisions only.  Service location change, additional house panel R, and insertion of gym and recreation rooms.))))  (((PROPOSED 22-UNIT  4-STORY APT.  BLDG.,  WITH 1-LEVEL SUBTER. PRIVATE PKG.  GARAGE.""2-VERY LOW INCOM UNITS.""                                                                                                                                PC FOR POWER AND ENERGY. DUE TO BUILDING SUBMITTAL, PC IN ACCORDANCE TO 2008 ENERGY STANDARDS.F.A variance is submitted on 4/1/16)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75902	13041-20000-08587	7918 N RESEDA BLVD	91335	12	189B125   433	2102015002	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Apartment			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.21434	-118.53587	Plan check for energy and emergency lighting. Plan check for lobby of apartment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75903	15041-10000-04908	2051 N CUMMINGS DR	90027	4	151-5A195 137	5589003014	RE11-1	Central	Hollywood	Los Feliz	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	03/23/2015 12:00:00 AM	ADDRESS	34.10868	-118.30205	Addition of a 4 microinverter branch circuit to existing solar PV array.  All circuits tied into one existing load center.Total system size = 7.35 kWac. Application is under B license. Plan check per customer request.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75904	14041-20000-33497	19344 W RUNNYMEDE ST	91335	3	186B117   953	2116016098	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1317.01	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	ADDRESS	34.20554	-118.55514	PV1 SFD. TOTAL SYSTM SIZE 3.6KW AC UISNG ENPHASE MICROINVERTER M215. USING STANDARD PLAN. TOTAL OF 17 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75905	12041-10000-31125												Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM			PC Approved	01/09/2013 12:00:00 AM				PV1 3 STORY HOUSE 22 MODULES [MODULES: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75906	13041-20000-01589	13557 W DELANO ST PV-1	91401	2	177B157   460	2330015007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2013 12:00:00 AM	02/05/2013 12:00:00 AM		Permit Finaled	03/06/2013 12:00:00 AM	ADDRESS	34.18223	-118.42885	solar single family	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75907	18041-10000-15386	5162-5164 W ADAMS BLVD	90016	10	123B177  1001	5049017010	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2198.00	Electrical	Electrical	Commercial			04/26/2018 12:00:00 AM	10/04/2019 12:00:00 AM		Permit Finaled	11/04/2021 12:00:00 AM	ADDRESS	34.03235	-118.35469	Change of use from retail to (2) new restaurant spaces and other future tenants. Service upgrade to 600 Amp. Full plan check for power and energy. (Core & Shell)Bldg Permit# 18016-30000-12241	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75908	19041-10000-33054	11966 W WAGNER ST	90230	11	108B161   222	4218007001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2755.00	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	33.99441	-118.41666	NEW 11.4KW AC / 13KW DC PV1 ROOF MOUNTED SYSTEM WITH 39 PV PANELS ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75909	19041-10000-53125	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	03/17/2020 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.06222	-118.35208	Title 24 energy plan check only. Scope of work includes adding new luminaires to a TI. Total affected area is 23,528 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75910	17041-20000-06359	6360 N CANOGA AVE flrs 3 14-15	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			02/28/2017 12:00:00 AM			PC Info Complete	02/28/2017 12:00:00 AM	ADDRESS	34.18619	-118.5972	ti to an existing hotel floors 3, 14, and 15 conference rooms.  adding new lighitng new controls to existing panels.  plan check for energy and em lighting only.  total quare footage 6129.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75911	16041-30000-31136	1135 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	11/22/2016 12:00:00 AM	ADDRESS	34.03011	-118.22062	Plan check Title 24 only in existing space T.I. remove oudoor lighting fixtures and replace with new LED lighting fixtures. Total area: 26,420 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75912	16041-30000-14600	445 S FIGUEROA ST 23rd floor	90071	14	130-5A209  15	5151020006	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			04/26/2016 12:00:00 AM			PC Approved	04/26/2016 12:00:00 AM	ADDRESS	34.05295	-118.25675	Plan check for energy Title 24 only in existing space T.I. in main corridor 23rd Floor. Total area: 2,125 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75913	18041-10000-29471	6915 N WILLIS AVE	91405	6	183B149   535	2219017002	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.03	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.19609	-118.4554	PV 1, NEW ROOF MOUNTED PV SYSTEM USING CENTRAL INVERTERS AND POWER OPTIMIZERS. (15) MODULES AND (1) 3.8KW INVERTER. TOTAL SYSTEM SIZE 3.8KWAC / 4.5KWDC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75914	18041-10000-39130	2049 S CENTURY PARK EAST 18TH FLOOR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/12/2018 12:00:00 AM	10/16/2018 12:00:00 AM		Permit Finaled	05/14/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	TENANT IMPROVEMENT IN EXISTING OFFICE SPACE ON THE 18TH FLOOR. 22,848 SQR FT OF T-24 ENERGY ONLY.BLDG PERMIT: 18016-10000-28461	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75915	19041-10001-09298	14006 W RIVERSIDE DR Suite 269	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			05/06/2019 12:00:00 AM			PC Approved	05/23/2019 12:00:00 AM	ADDRESS	34.15713	-118.43792	revision to T-24 planNote: Building application has been generated under 19016-40000-07212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75916	16041-10001-09207	3250 W WILSHIRE BLVD	90010	10	132B197    43	5094008027	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			06/27/2016 12:00:00 AM			PC Approved	06/27/2016 12:00:00 AM	ADDRESS	34.06162	-118.29337	PC FOR AN EXISTING FIRE ALARM SYSTEM FOR AN EXISTING COMMERCIALBUILDING. SCOPE INCLUDES REPLACING THE FIRE ALARM PANEL AND THE ANNUNCIATOR.NOTE: PERMIT IS PAID UNDER PCIS#16041-10000-09207	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75917	15041-20000-43400	7228 N AMIGO AVE	91335	3	183B121  1185	2118028063	(T)(Q)R3-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Apartment			01/15/2016 12:00:00 AM	02/16/2016 12:00:00 AM		Permit Finaled	03/22/2016 12:00:00 AM	ADDRESS	34.20195	-118.53846	Plan check for PV roof mounted system for Appartment building. System size: 10kWac and 32 modules and 2 inverters(5.0kW and 5.0kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75918	15041-10000-38169	9350 N GLENOAKS BLVD	91352	6	198B173    53	2538011009	M2-1-G	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			11/12/2015 12:00:00 AM	11/12/2015 12:00:00 AM		Permit Expired	12/12/2017 12:00:00 AM	ADDRESS	34.23869	-118.37549	PC FOR T24 ENERGY ONLY. CHANGING OUT 4 LIGHT FIXTURES TO LED. PERMIT ISSUED UNDER THIS APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75919	16041-10005-15022	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM			PC Approved	01/06/2017 12:00:00 AM	ADDRESS	33.94558	-118.4039	01/06/17PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGESARE CLOUDED AND NOTED UNDER DELTA DCN-024 ONLY. CHANGES INCLUDE REMOVING (1) LIGHTING FIXTURE ON FLOOR PLANS(IT ROOM), AND REVISING TITLE 24 CALCULATIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75920	14041-20000-12934	4919 E CORINGA DR	90042	14	157-5A225  95	5476008042	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1816.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2014 12:00:00 AM	05/28/2014 12:00:00 AM		Permit Expired	07/12/2016 12:00:00 AM	ADDRESS	34.12655	-118.20694	PV1 ROOF MOUNTED PV SYSTEM SIZED 8.25KW INTERCONNECTED WITH MAIN PANEL.MAIN PANEL UPGRADED TO 200A.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75921	16041-20000-33325	12918 W RUBENS AVE	90066	11	105B157   485	4223007023	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2016 12:00:00 AM	10/05/2016 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	33.98447	-118.42877	pv1install roof mounted pv system sized 10.2kw (acm) interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75922	13041-10000-01742	10700 W SANTA MONICA BLVD #160	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			01/23/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	ADDRESS	34.05167	-118.432	T24 CHANGED FROM RETAIL TO DRYCLEANERS. 870 Sqrft. Methane Zone however no underground work	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75923	15041-10000-11527	5217 W HOLLYWOOD BLVD 1-88	90027	13	148-5A195  53	5544010025	C2-1D	Central	Hollywood	Los Feliz		1904.01	Electrical	Electrical	Commercial			04/17/2015 12:00:00 AM	04/17/2015 12:00:00 AM		Permit Finaled	08/19/2015 12:00:00 AM	ADDRESS	34.10188	-118.30421	T24 FOR EXISTING RETAIL SPACE. SCOPE OF WORK IS ONLY IN THE BATHROOM AND ENTRANCE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75924	13041-10000-18019	810 S SPRING ST B2	90014	14	127-5A211 206	5144016044	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/09/2013 12:00:00 AM			PC Approved	07/18/2013 12:00:00 AM	ADDRESS	34.04268	-118.25375	PLAN CHECK FOR TITLE 24 PART 6 ENERGY AND EMERGENCY LIGHTING ON A HIGH RISE BUILDING. SPACE B2. FULL PLAN POWER PLAN CHECK SUBJECT TO INSPECTION. PERMIT HAS BEEN PULLED UNDER A SEPARATE APPLICATION PER APPLICANT (PLAN CHECK ONLY).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75925	19041-10000-45577	3485 S SAWTELLE BLVD 1-20	90066	11	117B157   389	4249026027	R3-1, [Q]R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			11/06/2019 12:00:00 AM	11/06/2019 12:00:00 AM		Permit Finaled	06/04/2020 12:00:00 AM	ADDRESS	34.01702	-118.42433	NEW FIRE ALARM SYSTEM WITH 31 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75926	17041-20000-41264	318 N WILTON PL	90004	4	138B193   322	5522033025	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			11/14/2017 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	08/29/2019 12:00:00 AM	ADDRESS	34.0768	-118.31338	New 5 Unit , 4 story apartment building with 600A 240/120V 1ph-3w service.  Plan check for power and energy.  Building application number 16010-30000-05160	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75927	12041-10001-30784	12751 W MILLENNIUM B	90094	11	102B161  1235	4211033050	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			01/22/2014 12:00:00 AM			PC Info Complete	01/22/2014 12:00:00 AM	ADDRESS	33.9761	-118.41651	REVISION TO APPROVED PLANS. DELTA 27 NAD 28 - ADD NEW CENTRAL WATER HEATING, CIRCULATING PUMP FOR BUILDING AND REMOVE GAS WATER HEATER FOR DWELLING UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75928	17041-20000-41392	8120 N JASON AVE	91304	12	189B093    48	2020021014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Permit Finaled	02/13/2018 12:00:00 AM	ADDRESS	34.21782	-118.63511	Plan check for solar pv system (w/roof-mounted array) and AC coupled battery backup system for SFD.(1) 3kW ungrounded pv inverter. (9) 300W pv modules. (9) 400W power optimizers.(2) 5kW Tesla Powerwall 2s.Existing 11kW pv system on site.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75929	10041-20000-07388	6040 E YORK BLVD	90042	14	154-5A231 147	5484016030	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1836.20	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	07/16/2010 12:00:00 AM		Permit Finaled	07/27/2010 12:00:00 AM	ADDRESS	34.11764	-118.18773	PLAN CHECK POWER AND ENERGY TI  FOR EXISTING RESTUARANT (A OCCUPANCY) MAX.OCCUPANT INCREASED FROM 154 TO 155	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75930	17041-10000-15286	213 S GAREY ST	90012	14	129A215   233	5163007013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM	05/09/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.04668	-118.23532	PC for energy only, Indoor/Outdoor Title 24. Removing HID fixtures and replacing them with new LED fixtures. Total area: 27,025 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75931	15041-20000-39673	7101 N OSO AVE #15	91306	3	183B113   925	2136007***	(Q)RD6-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Apartment			11/24/2015 12:00:00 AM			Reviewed by Supervisor	12/08/2015 12:00:00 AM	ADDRESS	34.19918	-118.57564	PV2, rooftop mounted solar on the Unit#15 apartement complex. 5kW AC system.   (24)modules #KU2656ZPA   (1)inverter: PVI-5000-OUTD	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75932	15041-20000-43175	12132 W HART ST 1-9	91605	2	183B165   276	2321009039	R3-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	Apartment			12/22/2015 12:00:00 AM	03/02/2016 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.19732	-118.39782	Plan check for New 9 units appartment Building. Service 600A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75933	19041-20000-33155	4047 N ELLENITA AVE	91356	3	162B117    47	2180004033	RA-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.14379	-118.55994	INSTALL 2 NEW TESLA POWERWALL BATTERIES ON EXISTING PV.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75934	12041-20000-21205	20000 S WESTERN AVE	90501	15, 7	222B157    94	2509014014	(T)(Q)C2-1VL, M3-1	Harbor, North Valley	Harbor Gateway, Sylmar	Harbor Gateway South, Sylmar		1061.14, 2920.00	Electrical	Electrical	Commercial			09/07/2012 12:00:00 AM	10/01/2012 12:00:00 AM		Permit Finaled	10/26/2012 12:00:00 AM	ADDRESS	33.85008	-118.30908	Plan check power and energy for existing warehouse building. New emergency power for lighting. Emergency generator and equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75935	18041-10000-06122	10280 N GLENOAKS BLVD	91331	7	204B165    87	2528007017	M2-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM	02/20/2018 12:00:00 AM		Permit Finaled	03/20/2018 12:00:00 AM	ADDRESS	34.25725	-118.39503	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75936	16041-20000-03842	4819 N GALENDO ST	91364	3	168B105   863	2171020047	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			02/03/2016 12:00:00 AM	02/22/2016 12:00:00 AM		Permit Finaled	03/25/2016 12:00:00 AM	ADDRESS	34.15348	-118.60086	Install a roof-mounted solar array on a SFD. Interconnect with a 225A MSP, 200A Main.System size: 11.4kW. Ungrounded system. Each module has a 400W power optimizer.(42) 325W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75937	13041-10000-15641	5626 N ALLOTT AVE	91401	2	174B157   512	2343012025	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2013 12:00:00 AM	06/17/2013 12:00:00 AM		Permit Finaled	10/30/2013 12:00:00 AM	ADDRESS	34.17292	-118.42783	PV1.  Installation of 4.9 kW DC roof-mounted solar array, interconnect into existing main service panel.  {20 modules: Hanwha HSL 60 250W} {Microinverters: Enphase M215-60-2LL-S22}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75938	17041-20002-11832	17075 W DEVONSHIRE ST	91325	12	204B133   139	2695020031	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			09/27/2017 12:00:00 AM			PC Approved	09/27/2017 12:00:00 AM	ADDRESS	34.2577	-118.50483	9.27.2017 - Plan check for modifications to approved set. Redesign of AC side of pv system - separating into two 100A systems, interconnecting at different 400A sections of main service board (derating main fuses of each section to 375A). Update SLD and roof plan to show changes - clouded delta 1.======PV2.  Install roof-mounted PV system sized 57.6kW interconnected with MSP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75939	13041-10000-22875	4550 W PICO BLVD C1-305	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			08/22/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	01/24/2014 12:00:00 AM	ADDRESS	34.04842	-118.33486	"TITLE 24 PLAN CHECK ONLY.  FIRST TIME TENANT. 1100 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER. Power plan check done under the supplemental. Permit to be pulled on this application.INVESTIGATION FEE DUE: Investigation fee due. Code Enforcement Order to Comply issued with effective date 06/17/2013 by Inspector GARY LYNCH at phone#(213)252-3089.  CEIS Case Number is 501237. Payment of investigation fee due at time of permit issuance. Paid 11/4/2013 by applicant ""COMPLY WITH DEPARTMENT ORDER effective date06/17/2013. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75940	12041-10000-16480	1241 S SOTO ST 2ND FLR	90023	14	121-5A221 175	5170017030	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			07/18/2012 12:00:00 AM			PC Info Complete	07/30/2012 12:00:00 AM	ADDRESS	34.02743	-118.21975	CHANGE OF USE FROM EX OFFICES TO ELEMENTARY SCHOOL (K - 5) CLASS RMS @ ENTIRE 2ND FLR OF EXISTING 2- STORY COVERED MALL.  Occupancy loaed is 548.  New panels, transformer, and circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75941	14041-10003-30882	849 W 34TH ST	90089	9	120A201    20	5039003027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/02/2016 12:00:00 AM	06/29/2016 12:00:00 AM		Permit Finaled	12/19/2016 12:00:00 AM	PIN	34.02383917	-118.28572873	*6/2/16: Supplemental PC and Permit.Changes under Delta-2: Install site lightings and new branch ckt associated with lightings and receptacle. PC for T-24 only, LTO forms per 2013 Energy code.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75942	10041-10000-20471	10619 S MAIN ST	90003	8	090A203   314	6074008008	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2411.20	Electrical	Electrical	Commercial			10/14/2010 12:00:00 AM			PC Approved	10/14/2010 12:00:00 AM	ADDRESS	33.93945	-118.27417	1 STORY,  120 SQ FT  ADDITION TO CONVERTED  RETAIL STORE AND INTERIOR REMODEL TO RETAIL AREA;  PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75943	13041-10000-05335	8856 N GERALD AVE	91343	12	195B137   406	2688040015	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	08/01/2013 12:00:00 AM	ADDRESS	34.23182	-118.49471	System size: 7.35 KW {30 modules: TSM-245 PC/PA05}{central inverter: 6 KW nominal output power - Fronius IG Plus V 6.0}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75944	12041-20000-11758	10725 N SAN FERNANDO ROAD	91331	7	207B157   508	2620002035	CM-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Public Safety Only			05/22/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.26496	-118.42123	New fire alarm system for warehouse building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75945	14041-20000-01981	1440 N NEPTUNE AVE	90744	15	036B205   946	7421027006	R1-1XL-O	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	01/23/2014 12:00:00 AM		Permit Expired	02/17/2016 12:00:00 AM	ADDRESS	33.79208	-118.26967	pv1 single family dwelling. total system size 3kw ac using transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75946	15041-20000-14669	9760 W PICO BLVD	90035	5	129B165  1239	4307004***	C4-1VL-O, R1-1-O	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	05/13/2015 12:00:00 AM		Permit Closed	08/30/2018 12:00:00 AM	ADDRESS	34.05401	-118.40151	Plan check for temporary power. Work includes a new 600-amp service, the installation of (1) 600-amp switchboard, and (1) 300 kVA transformer. Approved for counter plan check by E. M.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75947	19041-30000-15812	12068 W JUNIETTE ST	90230	11	105B161   822	4220007030	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.03	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/05/2019 12:00:00 AM	ADDRESS	33.98312	-118.40765	Plan check for a PV1 roof-mounted PV system. System size is 2.64 kWdc/2.52 kWac and consists of (8) modules and (8) micro-inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75948	13041-10000-06970	725 S FIGUEROA ST 3250	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM			PC Approved	03/19/2013 12:00:00 AM	ADDRESS	34.04886	-118.26071	PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS IN A HIGH RISE. SUITE 3250 ON 32ND FLOOR. NOTE: ALL TITLE 24 PERMITS SHALL BE OBTAINED THORUGH THE ELECTRICAL PLAN CHECK COUNTER. PERMIT PULLED UNDER DIFFERENT APPLICATION NUMBER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75949	13041-10000-33018	5732 N ENCINO AVE	91316	5	174B129   416	2254022013	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/15/2014 12:00:00 AM		Permit Finaled	01/30/2014 12:00:00 AM	ADDRESS	34.17477	-118.51401	PV1, Install 6.75 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(1)Transformerless inverter(s): SolarEdge SE6000A-US. (27) modules: Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75950	18041-10000-00217	20947 W ROSCOE BLVD	91304	3	192B109   680	2779007019	C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Issued	03/29/2018 12:00:00 AM	ADDRESS	34.22007	-118.59002	Energy plan check for a fire damage remodeling. Scope includes new lighting and equipment. Total area is 2,505 SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75951	14041-20000-01896	6057 N CARTWRIGHT AVE	91606	2	177B177   457	2414014001	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1231.04	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2014 12:00:00 AM	02/03/2014 12:00:00 AM		Permit Finaled	02/06/2014 12:00:00 AM	ADDRESS	34.18104	-118.36389	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75952	10041-10000-13802	11100 W SANTA MONICA BLVD #100	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2673.00	Electrical	Electrical	Commercial			07/19/2010 12:00:00 AM	07/19/2010 12:00:00 AM		Permit Finaled	09/15/2010 12:00:00 AM	ADDRESS	34.04726	-118.44465	TI in an existing office building. Plan check for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75953	15041-20000-25216	13462 W HERRON ST	91342	7	225B157   313	2510014008	RA-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.3153	-118.42606	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (16) modules, and (16) dc/dc converters. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75954	15041-20000-39662	13226 N KISMET AVE	91342	7	225B157   701	2512016044	R1-1	North Valley	Sylmar	Sylmar	YES	1061.12	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM	11/24/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.31127	-118.42076	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac. (18)MODULES-SW 2755 MONO BLACK MODULES(18)OPTIMIZER-SOLAR EDGE P320(1)INVERTER-SOLAR EDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75955	17041-10001-21151	3321 S LA CIENEGA BLVD	90016	10	120B173   270	4205033015	[T][Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2199.02	Electrical	Electrical	Apartment			06/13/2018 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Closed	01/05/2023 12:00:00 AM	ADDRESS	34.0275	-118.3723	[[6/13/18 CHANGES TO APPROVED SET. DELTA 8 CHANGES ARE CLOUDED. HIGH RISE. CHANGES INCLUDE REVISING SINGLE LINE DIAGRAM, ADDING PANELBOARDS, AND REVISING LIGHTING FLOOR PLAN LAYOUT. Plan check for Power and Title 24.  New mixed-use residential tower.  30-story residential tower with 300 units and structured parking located within a 5-story podium and a single level basement.  Retail spacewill be provided on the ground floor, along with tenant amenity areas on the 6th and 30th floors.  New 1000 amp 4,160 volt Main Switchboard with two 250 HP fire pumps and 1,000 kW diesel generator backup.  The incoming utility service is provided under separate plan check number 17041-10000-23479. Lighting area = 243,170 sq. ft. (indoor) + 45,288 sq.ft. (outdoor)       Building permit #16010-10000-04211	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75956	11041-10000-04968	1748 S COLBY AVE	90025	11	126B149   526	4261015020	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2673.00	Electrical	Electrical	Apartment			03/14/2011 12:00:00 AM	03/14/2011 12:00:00 AM		Permit Finaled	01/31/2012 12:00:00 AM	ADDRESS	34.04203	-118.45005	FIRE ALARM SYSTEM FOR 3 STORY APARTMENT BUILDING.  1 PANEL, 49 DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75957	18041-10001-08987	448 W OLYMPIC BLVD	90015	14	127-5A209 199	5139009015	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM	05/17/2019 12:00:00 AM		Permit Finaled	09/24/2019 12:00:00 AM	ADDRESS	34.04261	-118.26044	"Job Address is 1000 S Grand AveSuite address is 448 W. Olympic blvd. FIRST TIME TENANT. NEW ""PIZZA-FIRE"" RESTAURANT. PLAN CHECK FOR POWER ONLY. T-24 AND PARTIAL PERMIT WAS COVERED UNDER 18041-10000-08987<<<ti to an existing commercial space.  adding new lighting new controls to new panels.  newly connected load <400 amps.  plan check for energy only.>>>"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75958	19041-10000-22724	5335 E VALLEY BLVD	90032	14	139-5A237  91	5220033006	MR1-1	East Los Angeles	Northeast Los Angeles	LA-32	YES	2016.02	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Issued	06/14/2019 12:00:00 AM	ADDRESS	34.07475	-118.16696	Energy plan check for removing HID fixture and replace with new LED fixtures with a total lighting area of 50,940-SQ FT (in/outdoor).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75959	18041-10000-04314	137 N VIRGIL AVE	90004	13	138B197   658	5501007027	M1-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			02/06/2018 12:00:00 AM			PC Info Complete	02/06/2018 12:00:00 AM	ADDRESS	34.07469	-118.28704	PC FOR TITLE 24 FOR TI EXISTING OFFICE BUILDING ENERGY ONLY. TOTAL AFFECTED AREA 12888 SQ.FT. SCOPE INCLUDES NEW PANELS EQUIPMENT AND CIRCUITS. B# 18016-10000-02867	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75960	17041-10001-17789	2708 E CESAR E CHAVEZ AVE 101-302	90033	14	127-5A225  74	5180017002	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			05/26/2017 12:00:00 AM			PC Approved	05/31/2017 12:00:00 AM	ADDRESS	34.04477	-118.2039	PC per inspector request. Energy only for the music studio located in the first floor (rear). TI  under 2008 energy code. Permit under original #15041-10000-36772.Total affected area is 2953 Sq. FtPlan check only!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75961	19041-10000-35843	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Echo Park, Historic Cultural North	YES	1977.00	Electrical	Electrical	Commercial			10/03/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	08/24/2020 12:00:00 AM	ADDRESS	34.07196	-118.24719	FULL PLAN CHECK FOR A TI TO THE DODGERS STADIUM TO ADD (4) ESCALATORS INSIDE THE STADIUM GATES. SCOPE INCLUDES NEW LIGHTING, EQUIPMENT AND CONTROL. TOTAL AFFECTED AREA IS 89,676 SQ.FTBuilding Permit: 19014-10000-03549	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75962	14041-20001-07628	17336 W INDEX ST	91344	12	210B129    86	2711008022	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	34.2755	-118.51228	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM USING OPTIMIZERS 6.0KWAC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75963	15041-20002-13941	600 WORLD WAY Term 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	Changes to approved set.  Change of fixture type.  (((first tenant in commercial spacefull plan chk)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75964	15041-10000-20701	8239 N TOPANGA CANYON BLVD	91304	3	192B101   626	2012031015	P-1VL, [Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	07/07/2015 12:00:00 AM		Permit Finaled	07/16/2015 12:00:00 AM	ADDRESS	34.21944	-118.60633	TI-24 TO AN EXISTING BLD. P.C FOR ENERGY ONLY. TOTAL AREA: 5170 SQ. FT.SCOPE OF WORK: IMPROVEMENT IN DINING,SERVICE AREA., AND OUTDOOR  LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75965	14041-10000-22513	12582 W MILLENNIUM	90094	11	102B161  1292	4211010104	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Public Safety Only			08/19/2014 12:00:00 AM	08/19/2014 12:00:00 AM		Permit Finaled	11/18/2016 12:00:00 AM	ADDRESS	33.97749	-118.41246	new fire alarm system -core and shell- for 2-stories  over parking commercial building	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75966	19041-20001-30742	7203 N HYANNIS DR	91307	12	183B093    82	2027012015	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM			PC Approved	09/11/2019 12:00:00 AM	ADDRESS	34.2009	-118.64141	Expedited plan check fee.PV1.  Install 10.89 kW DC / 9.8 kW AC roof mounted grid tied PV system with 9.8 kWh DC-coupled energy storage system.  (33) modules with 6 and 3.8 kW rated inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75967	15041-20000-00688	11954 N SALEM DR	91344	12	216B133   361	2606021026	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2015 12:00:00 AM	01/21/2015 12:00:00 AM		Permit Finaled	02/10/2015 12:00:00 AM	ADDRESS	34.28787	-118.50669	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. Using 300W power optimizers.30  235/250W pv modules across 2 strings (15+15).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75968	15041-10001-03435	200 WORLD WAY #233	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/29/2015 12:00:00 AM			PC Approved	05/29/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Change toa an approved set by modifying the lighting floor plan and adding starters for equipment units.(((Plan check for power and title 24.  Total area = 550 sq. ft.Installation of new electrical distribution equipment (3 panels and 1 transformer in series) in airport space.  First time tenant.  New lighting and recepticles.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75969	16041-10000-01526	4619 N ARCOLA AVE	91602	4	168B177   859	2420026009	RE9-1	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	07/11/2016 12:00:00 AM	ADDRESS	34.1544	-118.35509	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7.6KW INTERCONNECTED WITH MSP.(27) REC SOLAR 275 MODULES(27) SOLAREDGE P300 OPTIMIZERS(1) SOLAREDGE 7600 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75970	18041-20000-10902	15541 W LANARK ST	91406	6	192B145   618	2654038013	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.21869	-118.47164	TI to (E) commercial studio.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75971	19041-20000-18076	20219 W WYNFREED LANE pv1	91326	12	216B113   206	2701048005	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/14/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	34.2917	-118.57413	pv1install roofmounted pv system sized 6.3KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75972	11041-20000-17963	11922 S VERMONT AVE	90044	15	084B197   351	6088020013	C2-1L	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	Commercial			08/24/2011 12:00:00 AM			PC Approved	08/24/2011 12:00:00 AM	ADDRESS	33.92425	-118.29139	Loading dock demolishing & constructinof new loading dockT-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75973	15041-20000-39151	9250 N DORRINGTON AVE	91331	6	198B153   651	2642027005	RA-1	North Valley	Arleta - Pacoima	Arleta		1194.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2015 12:00:00 AM	01/08/2016 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.23848	-118.43717	PV1, roof mounted solar panel kkW AC system.   (28)modules: SUNEDISON270,  (1)inverter: SE6000A-US.  (Submittal per Applicant)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75974	16041-20000-04927	14006 W RIVERSIDE DR MACY'S	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Issued	03/15/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,360 sq. ft. Note: Building application has been generated under 16016-20000-03065	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75975	12041-20000-03946	2911 N DENBY AVE	90039	13	150B213   932	5442022024	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM	02/22/2012 12:00:00 AM		Permit Finaled	03/03/2014 12:00:00 AM	ADDRESS	34.10378	-118.2441	energy plan check storage building 800 square feet	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75976	10041-20000-25118	1200 S SANTA FE AVE	90021	14	123A217   315	5166007011	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			12/16/2010 12:00:00 AM	12/12/2011 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.02944	-118.22979	"PLAN CHECK POWER AND ENERGY FOR NEW ELECTRICAL SYSTEM FOR EXISTING MANUFACTURING/WAREHOUSE TO 53 FUTURE MANUFACTURING SPACES. TWO 1600A SERVICES SUPPLYING BUILDING. VARIANCE ""SPECIAL PERMISSION"" TO ALLOW ADDITIONAL SERVICE HAS BEEN FILED. EACH UNITS IN BUILDING LOADS ARE FUTURE AND SUBJECT FOR PLAN CHECK. ""COMPLY WITH DEPARTMENT ORDER effective date11/18/2008. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75977	13041-10001-36247	11184 N LAUREL CANYON BLVD	91340	7	210B149   454	2613023055	R1-1	North Valley	Arleta - Pacoima	Mission Hills		1095.00	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.27353	-118.44757	Expedited RSES plan check per applicant request.{{PV1, Install 3.75 kW DC roof-mounted solar array for a two story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 3800A-US. (15) Modules: Trina Solar TSM-250PA05.18.(15) Optimizers: Solaredge OP250-LVMC4SM-2NA-Z}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75978	17041-10000-19100	800 N PASEO MIRAMAR	90272	11	129B117    28	4416022039	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		Yes	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Expired	03/17/2020 12:00:00 AM	ADDRESS	34.04968	-118.55753	PC FOR BATTERY BACKUP SYSTEM. USING 2 TESLA POWERWALL UNITS. TOTAL SIZE 11.6KWAC WITH TOTAL 26 KWH STORAGE CAPACITY. INSTALLING NEW LOAD CENTER FOR COMBINER WITH (E) SOLAR PRODUCTION. PC FOR NEW STAND BY PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75979	12041-10000-01154	6255 W SUNSET BLVD 1800	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			01/18/2012 12:00:00 AM			PC Approved	01/27/2012 12:00:00 AM	ADDRESS	34.09815	-118.32564	T.I. to an existing office space.  Change to lighting and adding recptacles.  PLAN CHECK ONLY for Energy, with Emergency lighting.  Unit 1800	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75980	17041-20000-29102	15253 W GOLDEN CT	91342	7	219B145   688	2611041026	RS-1	North Valley	Sylmar	Sylmar	YES	1066.49	Electrical	Electrical	1 or 2 Family Dwelling			08/16/2017 12:00:00 AM	08/25/2017 12:00:00 AM		Issued	08/25/2017 12:00:00 AM	ADDRESS	34.29481	-118.46533	Plan check for a PV1 roof-mounted PV system with battery back-up. System size is 6 kWac and consists of (1) inverter, (19) modules, (1) 5 kWac Powerwall, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75981	09041-10004-05908	1460 N VINE ST	90028	13	147A189    91	5546025015	C4-2D-SN	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			06/09/2010 12:00:00 AM			PC Approved	06/09/2010 12:00:00 AM	ADDRESS	34.09734	-118.32646	DELTA 8 REVISIONS ; CHANGES TO LIGHTING PLAN WITH REVISIONS TO TITLE 24 COMPLIANCE FORMS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75982	17041-10001-44588	115 S GRAMERCY PL	90004	4	138B193  1101	5516017018	[Q]RD1.5-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.07263	-118.31259	Change to approved set by adding a disconnect on the floor plan.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75983	15041-20000-10226	19131 W VICTORY BLVD BLDG 8	91335	3	180B121   532	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM	04/29/2015 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.18674	-118.55038	PV2. ROOFMOUNTED SOLAR SYSTEM. TWO MIRRORED BUILDINGS ONE ADDRESS.  (2 OF 2 BUILDING 8 ONLY )  SYSTEM SIZE: 2. 75 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75984	15041-10000-16304	12516 W OSPREY LANE #1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM			PC Approved	05/28/2015 12:00:00 AM	ADDRESS	33.97884	-118.41153	((((5/28/2015))))PV2 INSTALL ROOF MOUNTED PV SYSTEM FOR UNIT 1 SIZED 2.76KW INTERCONNECTED WITH MSP.PERMIT FEES UNDER APPLICATION NUMBER 14041-20000-19513	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75985	16041-10000-33192	444 S HARBOR BLVD #BERTH 86	90731	15	015B201   221	7440030***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			09/19/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	11/15/2016 12:00:00 AM	ADDRESS	33.7408	-118.27839	Plan check for T24 only. Remove indoor+outdoor HID fixtres and replace with LED fixtures. Total area: 35,900 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75986	13041-10000-02993	3435 W WILSHIRE BLVD #100	90010	10	132B197    26	5502030014	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.00, 2123.04	Electrical	Electrical	Commercial			02/05/2013 12:00:00 AM	04/03/2013 12:00:00 AM		Permit Finaled	06/03/2013 12:00:00 AM	ADDRESS	34.06194	-118.29866	"Tenat improvement at the Commomwealth Business Bank plan chk si for title 24""COMPLY WITH DEPARTMENT ORDER effective date 12/13/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""INVESTIGATION FEE DUE:  Investigation fee due. Code Enforcement Order to Comply issued with effective date 12/13/2012 CEIS Case Number is 486188. Payment of investigation fee due at time of permit issuance."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75987	14041-20000-06407	653 N LA CIENEGA BLVD	90069	5	141B173   496	4337003053	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			03/10/2014 12:00:00 AM	03/10/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.08351	-118.37676	T.I.  to existing space.  Install indoor and outdoor general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75988	19041-30000-53321	5050 W PICO BLVD	90019	10	129B181  1003	5070017034	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Apartment			12/26/2019 12:00:00 AM	12/26/2019 12:00:00 AM		Permit Finaled	08/10/2021 12:00:00 AM	ADDRESS	34.04771	-118.34793	PC FOR A NEW FIRE ALARM SYSTEM, SCOPE INCLUDES A NEW FIRE ALARM PANEL, WITH A NEW COMMUNICATOR, AND 3 REMOTE POWER SUPPLIES, WITH 184 DEVICES.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
75989	19041-20000-38889	704 N WILDOMAR ST	90272	11	129B125   618	4413002015	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2627.04	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.04698	-118.53594	PV1. INSTALL 6.205 KW DC PV SYSTEM WITH (17) MODULES AND OPTIMIZERS AND (1) INVERTER (SE7600H). SCOPE OF WORK INCLUDES (1) LG STORAGE BATTERY.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
75990	13041-10000-24715	14722 W MAGNOLIA BLVD UNIT 1	91403	4	171A149    26	2263037008	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	11/18/2013 12:00:00 AM	ADDRESS	34.16462	-118.45387	PV2.  Instal 1.68 kW DC roof-mounted solar array of 7 modules, interconnect with apartment unit panel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75991	19041-10000-24008	2626 W COLORADO BLVD	90041	14	163-5A219 162	5682002024	[Q]C4-2D	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	Commercial			06/21/2019 12:00:00 AM			PC Info Complete	07/01/2019 12:00:00 AM	ADDRESS	34.14192	-118.22342	PC FOR T24 ENERGY ONLY FOR EXTRIOR LIGHTS IN EXISTING TARGET. TOTAL  AFFECTED AREA 200 SQ.FT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES WITH NEW CIRCUITS. B#19016-10000-18947	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75992	17041-20000-41836	22734 W STAGG ST	91304	12	189B097  1065	2013033003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1343.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2017 12:00:00 AM	01/19/2018 12:00:00 AM		Permit Finaled	05/02/2018 12:00:00 AM	ADDRESS	34.21089	-118.62266	ENERGY STORAGE SYSTEM 9.8KWH + PV1 ROOFMOUNTED SOLAR SYSTEM . SYSTEM SIZE: 7.37 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75993	18041-10002-23390	1633 W 70TH ST	90047	8	102B193   921	6015027013	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2373.00	Electrical	Electrical	1 or 2 Family Dwelling			06/22/2018 12:00:00 AM	09/27/2018 12:00:00 AM		Permit Finaled	10/24/2018 12:00:00 AM	ADDRESS	33.97629	-118.30566	SCOPE INCLUDES (1) TESLA POWER WALL BATTERY WITH NEW LOAD CENTER, 13.5 KWH ESS. PV PERMIT IS UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75994	16041-10000-30897	372 E 2ND ST	90012	14	129A215   127	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			08/30/2016 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	12/14/2016 12:00:00 AM	ADDRESS	34.04788	-118.23987	T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM RETAIL TO RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLE.S TOTAL AFFECTED AREA IS 1106 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75995	13041-10000-01802	724 N AVENUE 64	90042	14	156A233   370	5716010014	R1-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1831.02	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	01/28/2013 12:00:00 AM		Permit Finaled	05/17/2013 12:00:00 AM	ADDRESS	34.12051	-118.17777	PV1 ROOF MOUNTED SOLAR INSTALLATION USING MICROINVETER STANDARD PLAN.  TWO STORY HOUSE. SYSTEM SIZE IS 3.024 KW. USING 14 MODULES IN A SINGLE CIRCUIT. [INVETER: ENPHASE # M215-60-2LL-S22 |||| MODULE: REC # REC 245 PE]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
75996	14041-20000-05232	5833 S WEST SEAGLASS CIR	90094	11	102B157   398	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			02/25/2014 12:00:00 AM	04/11/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	33.97367	-118.41982	ROOF-MOUNTED,PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3KW AC USING TRANFORMERLESS INVERTER NONSTANDARD PLAN	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75997	19041-20000-31326	23410 W BESSEMER ST	91367	3	177B093   614	2035004030	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.18012	-118.63771	PV1. INSTALL 9.72 KW DC / 8.50KW AC ROOFMOUNTED SYSTEM WITH (27) MICROINVERTERS AND (1) SONNEN BATTERY SYSTEM ON EXISTING 200 AMP SERVICE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
75998	15041-10000-42836	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM	01/28/2016 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	33.94955	-118.38214	PC FOR POWER ONLY. SCOPE OF WORK INCLUDES A NEW CHILLER CONTROL PANEL CONNECTED TO A 700 AMP BREAKER AND A PUMP CONTROL PANEL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
75999	11041-10000-01836	1717 S LINCOLN BLVD	90291	11	111B149  1401	4241018031	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM	02/15/2011 12:00:00 AM		Permit Finaled	08/13/2011 12:00:00 AM	ADDRESS	33.99633	-118.45783	T-24 only plan check for restarant remodel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76000	16041-20000-41228	4169 N GREENBUSH AVE	91423	4	165B157   928	2373007015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2016 12:00:00 AM	12/06/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.14615	-118.42621	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.915 KW.Note: $0.00 permit fee due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76001	14041-20000-05999	14745 W MACLAY ST	91345	7	210B149   314	2664011061	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/30/2014 12:00:00 AM	ADDRESS	34.27425	-118.4536	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN. USING POWER OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76002	18041-10000-16624	5015 N EAGLE ROCK BLVD 201, 203-205, 207	90041	14	162A221   218	5686021030	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			05/04/2018 12:00:00 AM	05/21/2018 12:00:00 AM		Permit Finaled	09/19/2018 12:00:00 AM	ADDRESS	34.13746	-118.21479	PC FOR TI-24 ONLY FOR A TI IN AN EXISTING OFFICE PLACE. SCOPE INCLUDES NEW CIRCUITS, LIGHTING AND RECEPTICALS ON EXISTING PANELS. NEWLY CONNECTED LOAD < 400AMPS ( INSPECTOR TO VERIFY )TOTAL AFFECTED AREA IS 5212 SQ.FTLOW VOLTAGE ON 2ND FLOORBUILDING APPLICATION # 18016-10000-10001	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76003	12041-10000-10545	168 BERTH	90744	15	018B201   130	7440026903	M2-1, [Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			05/08/2012 12:00:00 AM			Reviewed by Supervisor	05/29/2012 12:00:00 AM	PIN	33.7478016	-118.27948576	Installation of  105C 5kv multi-conductors  cable from an existing 2.4KV MVSTR ,ONTO EXISTING CABLE TRAY ( Class I Div2) to an existing 400 HP pump-motor ( Class I Div 2 )	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76004	17041-20001-37841	1333 N SIERRA BONITA AVE	90046	4	147B177  1376	5550027012	R3-1	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Apartment			08/13/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	34.09531	-118.35409	Revisions to approved set of plans.  Change of service rating from 600A 240/120V 1ph-3w to 600A 240/120V 3ph-4w.  Other distributional changes.  Updates to voltage drop, fault current calculations.  Exterior and emergency lighting detail changes. (((Plan check for power and energy. New 4-story, 6-unit apartment building above one level subtarranean parking. 600A service.  Plan check for power and energy.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76005	16041-10000-05016	5245 W SANTA MONICA BLVD	90029	13	144B193   695	5537009018	[Q]C2-2D	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Commercial			02/11/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Issued	06/02/2016 12:00:00 AM	ADDRESS	34.09094	-118.30401	New Fire alarm system on a mixed-use builds (bld-A and B) sharing a 2-level underground parking. Main fire alarm  Panel located in bld-B; Scope includes 2-fire alarm panels, 10-control panels, 2-communication panels, and a total of   (307) devices. Reference building permit is under 10010-10000-02297 and 10010-10006-02297Conduit only permit is pulled under 16041-10000-18689 on 5/27/16.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76006	19041-10001-38646	1316 S MALCOLM AVE	90024	5	132B153   569	4325011019	R1-1-O	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2019 12:00:00 AM			PC Approved	10/04/2019 12:00:00 AM	ADDRESS	34.05743	-118.43895	***EXPEDITE FEES***NEW 12.86KW ROOF MOUNTED PV SYSTEM WITH 42 PV PANELS ON A SINGLE FAMILY HOME.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76007	11041-10000-00317	5500 W 83RD ST	90045	11	099B173   828	4127024001	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			01/07/2011 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	04/21/2011 12:00:00 AM	ADDRESS	33.96342	-118.37567	TENANT IMPROVEMENT (N) OFFICES @ 7,360 SF.  PLAN CHK IS FOR TITLE 24Note: Per contractor, permit does not include 45KVA transformer and a 200 bus rating panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76008	14041-10000-23570	225 S OLIVE ST	90012	14	130-5A211   9	5149010***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Apartment			08/28/2014 12:00:00 AM	04/19/2017 12:00:00 AM		Permit Finaled	02/22/2024 12:00:00 AM	ADDRESS	34.05317	-118.24961	Plan check for energy (indoor and outdoor) on an alteration for highrise building, work applies to each floor corridor  in the whole building. Additional work  apply to ground and third floor. total working area is 27119 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76009	18041-20000-41904	202 S OCEANO DR	90049	11	132B141   282	4404033014	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/15/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.05921	-118.47278	PV1.  Install 16.92 kW roof mounted grid tied PV system.  (47) AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76010	12041-10000-03836	13716 N HERRICK AVE	91342	7	228B141   270	2603020019	RA-1-K	North Valley	Sylmar	Sylmar		1065.10	Electrical	Electrical	Commercial			02/21/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.32012	-118.47359	SFD ROOF NSTALLATION OF  8.46KW PHOTOVOLTAIC SYSTEM-36 MODULES, 1 COMBINER AN A INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76011	14041-20000-28596	2015 W ADAMS BLVD	90018	10	123B193   530	5058014010	R1-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			10/15/2014 12:00:00 AM	02/26/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.03286	-118.30951	FIRE ALARM SYSTEM FOR SENIOR LIVING. TOTAL OF 152 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76012	11041-10000-13138	1000-1014 S DOREEN PL BLDG 44	90291	11	111B145   665	4243003037	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			07/15/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	10/03/2013 12:00:00 AM	ADDRESS	34.00038	-118.46076	ALTERATIONS AND RENOVATIONS OF 29-UNITS APARTMENT BUILDINGVARIANCE IS REQUIRED TO SEPARATE THE FA PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76013	15041-10000-09216	12324 W MOORPARK ST	91604	2	165B165   401	2367002021	R3-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Apartment			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/11/2016 12:00:00 AM	ADDRESS	34.15015	-118.40165	INSTALLATION OF NEW FIRE ALARM SYSTEM FOR 8 UNITS APARTMENT. Scope includes (1) fire alarm panel, (1) annuciator panel, and (40) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76014	18041-10000-36887	333 S GRAND AVE SUITE 4375	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/26/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	12/10/2018 12:00:00 AM	ADDRESS	34.05271	-118.25179	Energy plan check for an office TI located on the 43th floor of a high rise building. Scope includes new lighting and equimpent with a total area of 1514-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76015	16041-10001-42037	5250 W SANTA MONICA BLVD #208	90029	13	144B193   736	5537020029	[T][Q]C2-1D	Central	Hollywood	East Hollywood		1916.20	Electrical	Electrical	Commercial			12/13/2016 12:00:00 AM			PC Approved	12/13/2016 12:00:00 AM	ADDRESS	34.09066	-118.30496	PC FOR MEDICAL CLINIC. POWER ONLY. PERMIT ALREADY ISSUED. PC PER ART. 517	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76016	19041-10000-35129	6336 N CANOGA AVE	91367	3	180B105    72	2149001033	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1349.05	Electrical	Electrical	Commercial			09/12/2019 12:00:00 AM			PC Info Complete	03/05/2020 12:00:00 AM	ADDRESS	34.18572	-118.5972	FULL PLAN CHECK FOR A NEW CONSTRUCTION OF 3 STORY  CREATIVE OFFICE BUILDING CONSISTING OF 65,809SF OF IN/OUTDOOR  AREA. SCOPE INCLUDES (1) 1200-AMP 277/480V SERVICE, (20) PANEL S AND OTHER ASSOCIATED EQUIPMENT FOR CORE/SHELL ONLY.Building Permit: 19010-10000-03519	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76017	14041-10000-04915	9727 N LAUREL CANYON BLVD	91331	7	201B161   692	2626003014	(Q)C2-1VLD	North Valley	Arleta - Pacoima	Pacoima		1048.22	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	02/21/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.24624	-118.4193	INSTALLATION OF A NEW FIRE ALARM SYSTEM. FULLY SPRINKLERED. 1 STORY. 1 PANEL AND 24 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76018	18041-10001-18665	523 W 6TH ST	90014	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/16/2018 12:00:00 AM			PC Approved	11/16/2018 12:00:00 AM	ADDRESS	34.04864	-118.25484	Change to approved set by changing the lighting contorl and lighting design on the floor plan. All changes under delta-4 only.(((T-24, PC FOR ENERGY ONLY. CHANGE OF USE FROM STORE TO RESTUARANT. SCOPE INCLUDES ADDING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2261 SQ. FT. B#18016-10000-15858)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76019	19041-30000-01750	12080 W VENTURA PL	91604	2	165B165  1269	2368002041	C2-1L-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1438.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			Corrections Issued	01/15/2019 12:00:00 AM	ADDRESS	34.14464	-118.39517	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 683 sq. ft.Note: Building application has been generated under [NOT YET FILED]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76020	17041-20000-08297	9171 N GAZETTE AVE	91311	12	198B109   142	2748036024	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	08/01/2017 12:00:00 AM	ADDRESS	34.23761	-118.58729	Plan check for a PV2 roof-mounted PV system. System size is 36 kWac and consists of (3) inverters, (126) modules, and (1) solar load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76021	17041-10000-43334	508 W 155TH ST	90248	15	072B201   186	6120026011	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2017 12:00:00 AM	12/01/2017 12:00:00 AM		Permit Expired	10/12/2023 12:00:00 AM	ADDRESS	33.89043	-118.28345	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.565KWdc / 3.8KWac.(9)MODULES-SOLARWORLD SW285(9)OPTIMIZERS-SOLAREDGE P300(1)INVERTER0SE 3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76022	19041-10000-11453	6160 N LAUREL CANYON BLVD SUITE 110	91606	2	177B165   349	2334011027	C4-1L, P-1L, QC4-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Finaled	03/16/2020 12:00:00 AM	ADDRESS	34.18234	-118.39628	INTERIOR TENANT IMPROVEMENT TO AN EXISTING SHELL SPACE TO ADD A NEW CALIFORNIA FISH GRILL RESTAURANTPC FOR FIRST TIME TENANT.  SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL AFFECTED AREA 2656B#19016-10000-07195	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76023	17041-10000-15436	21816 W DEVONSHIRE ST	91311	12	204B101   191	2747016003	[Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			05/09/2017 12:00:00 AM			PC Info Complete	05/09/2017 12:00:00 AM	PIN	34.25695385	-118.60450649	CHANGE OF USE FROM (E) RETAIL (1000 SQFT) TO (N) BEAUTY SALON	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76024	18041-10001-16895	10624 N LAS LUNITAS AVE	91042	7	207B197  1026	2566010020	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1011.10	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.262	-118.2912	PC FOR CHNAGES TO APPROVED SET TO REFLECT FIELD INSTALLATION. SCOPE INCLUDES NEW DISCONNECT. THIS IS PLAN CHECK ONLY!	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76025	14041-20000-35219	247 S HOOVER ST	90004	13	136-5A201 117	5501019003	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	1 or 2 Family Dwelling			12/19/2014 12:00:00 AM	12/19/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	ADDRESS	34.06898	-118.28451	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 4.2KW INTERCONNECTED WITH MSP.(14) SUNPOWER 327W MODULES(1) ABB PVI-4.2-OUTD INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76026	18041-20002-21197	9910 N BARTEE AVE	91331	6	201B157   115	2645006043	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM			PC Approved	09/14/2018 12:00:00 AM	ADDRESS	34.25051	-118.43188	Plan check for lost set of plan. Install 8.125 kW DC roof mounted grid tied PV system and 13.5 kWh energy storage system.  (25) modules with 7.6 kW rated string inverter. Plan check only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76027	18041-20000-24829	5757 W WILSHIRE BLVD suite p2	90036	4	135B177   470	5508015007	(T)(Q)C4-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	08/21/2018 12:00:00 AM		Permit Finaled	01/14/2019 12:00:00 AM	ADDRESS	34.06259	-118.35341	Plan check for power and energy for existing medical office space. Total area: 2184 sq ft. Phase 1 of projectB#18016-30000-19708	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76028	18041-10000-45948	15001 W RAYMER ST	91405	6	189B145   725	2209031005	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Van Nuys		1272.10	Electrical	Electrical	Commercial			12/04/2018 12:00:00 AM	12/04/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.21353	-118.46001	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76029	12041-10000-21444	690 W KNOX ST	90502	15	057B197    80	7351033024	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/11/2012 12:00:00 AM			Corrections Issued	09/11/2012 12:00:00 AM	ADDRESS	33.85406	-118.28817	TI REMODEL  IN AN EXISTING OFFICE BLDG. EPC IS FOR T24.; UNIT  # 100. (permit was pulled under separate application)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76030	18041-10000-00985	5921 N FIGUEROA ST	90042	1	151-5A229  20	5492013900	PF-2D-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1836.20	Electrical	Electrical	Commercial			01/10/2018 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.11103	-118.19024	T-24, PC FOR ENERGY ONLY. REPLACING EXISTING FIXTURES WITH NEW LED FIXTURES. TOTAL AFFECTED AREA IS 2025 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76031	19041-20000-03011	15742 W SAN FERNANDO MISSION BLVD	91344	12	210B141   586	2662012018	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1093.00	Electrical	Electrical	Commercial			01/25/2019 12:00:00 AM	03/14/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	PIN	34.27153203	-118.47547916	Plan check for PV roof mounted system on existing commercial preschool building, system size: 20.8KW DC/18.12KW AC CEC/13.68KW AC with (57) LG365Q1C PV Modules and (57) enphase IQ7-60-2 microinverters connected to existing 400A Service, and (1) 200a load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76032	09041-20005-24366	3327 E SABINA ST Bldg A	90023	14	123A227   438	5186015039	C2-1, RD1.5-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2048.10	Electrical	Electrical	Apartment			11/03/2011 12:00:00 AM	11/08/2011 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.0306	-118.20046	Delta 5 Revision to approved plans for New Apartment Complex w/ multiple buildings (Bldg A) 1of 2 Building. Changes includes lighting, provide disconnects for ATS, relocate boilers and recirculation pump ckts, add light/fan ckt and revise meter phasing.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76033	10041-10000-00519	849 N ALAMEDA ST	90012	14	132A215    43	5408011908	PF-1VL	Central	Central City	Historic Cultural		2071.00	Electrical	Electrical	Commercial			01/12/2010 12:00:00 AM	03/03/2010 12:00:00 AM		Permit Finaled	08/24/2010 12:00:00 AM	ADDRESS	34.05756	-118.23746	TI to split one space in two for a take-out bakery and an empty shell.  T-24 and emergency lighting.  Lighting in the shell is existing to remain.  Plans shall be checked under 2005 Energy Standards.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76034	14041-20000-35977	6080 W CENTER DR 10th-11th floor	90045	11	102B169    33	4104001079	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			12/31/2014 12:00:00 AM	01/08/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	33.97713	-118.39172	Energy plan check only. TI to existing office building. Adding lighting and emergency on 10th and 11th floors. 5419 Sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76035	13041-20000-02551	920 S BROXTON AVE	90024	5	135B149   572	4363018008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM			PC Approved	03/28/2013 12:00:00 AM	ADDRESS	34.06313	-118.44685	Lighting change to existing restaurant.  Load is less than 400 amps and occupancy load is less than 99 per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76036	16041-10000-20791	404 S FIGUEROA ST 35th-Floor	90071	14	130-5A209  28	5151020007	C4-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			06/14/2016 12:00:00 AM	09/29/2016 12:00:00 AM		Permit Finaled	08/02/2017 12:00:00 AM	ADDRESS	34.05326	-118.25596	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING RESTAURANT ON THE 35TH FLOOR.  SCOPE INCLUDES NEW LIGHTS AND CONTROLS. TOTAL AFFECTED AREA IS 1532 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76037	13041-20000-12180	12543 N WOODLEY AVE	91344	12	219B137    25	2609013016	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2013 12:00:00 AM	05/10/2013 12:00:00 AM		Permit Expired	06/03/2015 12:00:00 AM	ADDRESS	34.2994	-118.49664	PV1 1-STORY SINGLE FAMILY DWELLING. 6.37KW TOTAL SYSTEM SIZE. STANDARD PLAN. [INVERTER: SUNNY BOY 5000-US] [SOLAR MODULE: TRINA SOLAR TSM-245 PC/PA05]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76038	13041-10000-12797	12530 N ARISTO PL	91344	12	219B129   262	2608011033	RE11-1-H-O	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2013 12:00:00 AM	05/16/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	34.29809	-118.51522	PV1 XFRMless. 2 STORY HOUSE. nonSTD. ROOFMOUNT.  [ 1 INV: solaredge SE5000A-US] [ 20 MOD: TRINA TSM-245PC05} WITH OPTIMIZERS]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76039	13041-20000-31041	13625 W VENTURA BLVD	91423	4	165B157   627	2360006028	C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1411.01	Electrical	Electrical	Commercial			11/06/2013 12:00:00 AM	11/12/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.14804	-118.43036	NEW SERVICE FOR EXISTING BUILDING. PC FOR SERVICE ONLY. 800A. NEW TENANTS TO MOVE IN FOR BUILD OUT WILL BE SUBJECT TO FULL PLAN CHECK FOR FIRST TIME OCCUPANCY TO NEW SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76040	13041-10000-13500	5064 N LANKERSHIM BLVD	91601	2	171B173   942	2353008015	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			05/23/2013 12:00:00 AM			Reviewed by Supervisor	06/12/2013 12:00:00 AM	ADDRESS	34.16268	-118.37307	PV2.  New 11.445 kW DC photovoltaic system roof-mounted solar array on a 1-story commerical building interconnect into existing main service panel.   {35 modules: SunPower E20/327} {Central inverter: SunPower SPR-10001F-1}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76041	10041-20001-20754	7000 W HOLLYWOOD BLVD	90028	13	147B181   199	5548007008	C4-2D-SN, R4-2D	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			01/13/2011 12:00:00 AM			PC Info Complete	01/13/2011 12:00:00 AM	ADDRESS	34.10137	-118.34182	"Supplemental changes from previously approved plans.  Changes in general lighting wattages.  All changes are clouded as shown on plans.  Plan check for energy only.  Note:  Permit is under 10041-20000-20754.*****T.I. in the existing high rise building of ground floor of Public Kitchen and Bar.  Install general/emergency lighting.  Plan check for energy only.*****""COMPLY WITH DEPARTMENT ORDER effective date11/13/2007. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76042	14041-20001-34819	4834 N LA RODA AVE	90041	14	160-5A225 320	5689007034	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1814.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.13438	-118.20611	EXPEDITE PER CUSTOMER REQUEST.PV1. INSTALL ROOF MOUNTED PV SYSTEM SIZED 4 KW. INTERCONNECTED WITH MAIN SERVICE PANNEL. (16) SOLARWORLD PLUS SW-275 MODULES(16) ENPHASE M250-60-2LL-S22 MICRO INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76043	14041-10000-00924	20501 W ROSCOE BLVD	91306	3	192B109   743	2780028075	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.22	Electrical	Electrical	Commercial			01/13/2014 12:00:00 AM			PC Approved	03/26/2014 12:00:00 AM	ADDRESS	34.22027	-118.58011	T.I. to existing building.  Install general lighting.  Plan check for energy only.Note: Permit is under a separate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76044	16041-10000-39895	5755 W 96TH ST	90045	11	093B169   128	4125021030	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			11/10/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	33.94955	-118.38214	PC FOR NEW 600A PANELBOARD THAT WILL BE FEEDING A REPLACEMENT UNIT LINE 28. THE REPLACEMENT LINE NOT INSTALL YET. ONLY 600A FEEDER AND PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76045	10041-20000-17095	139 1/2 N LARCHMONT BLVD	90004	4	138B189   807	5515019019	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/30/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	ADDRESS	34.07418	-118.32383	T.I. to existing building.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76046	11041-10000-06401	1505 N EDGEMONT ST	90027	13	147B197   644	5543007025	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			03/31/2011 12:00:00 AM			PC Approved	03/31/2011 12:00:00 AM	ADDRESS	34.09843	-118.29637	TI TO AN EXISTING OFFICE BUILDING. T-24 OTC PLAN CHECK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76047	13041-10000-11140	9210 N SAN FERNANDO ROAD	91352	6	198B169   119	2538002046	M1-1, M2-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			04/30/2013 12:00:00 AM			PC Approved	06/12/2013 12:00:00 AM	ADDRESS	34.23693	-118.39033	TENANT IMPROVEMENT FOR EXISTING OFFICE BUILDING. SCOPE OF WORK IS 954 CONDITIONED AND 1474 UNCONDITIONED SQUARE FEET OF INTERIOR LIGHTING. PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76048	18041-10000-26010	655 S HOPE ST #LM101	90017	14	129A209   262	5144006901	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/12/2018 12:00:00 AM			PC Info Complete	07/16/2018 12:00:00 AM	ADDRESS	34.04849	-118.25759	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT TO DUNKIN DONUTS in Suite #LM101.480 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76049	16041-10000-38582	10250 W SANTA MONICA BLVD # 1760	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2016 12:00:00 AM	01/11/2017 12:00:00 AM		Permit Finaled	04/07/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for New Tenant ""Origins"" Ste. 1760.  Install new panels and its circuits, lights and receptacles. Total effected area: 517 sq.ft. using performance method."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76050	19041-10000-19553	126 N NORTH BROADWAY	90012	14	130-5A213   8	5161005925	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM			PC Info Complete	07/09/2019 12:00:00 AM	PIN	34.05370573	-118.24461596	Full pc (Pwr and Energy) for New 3-story Restaurant and outdoor dining area. service size is 1200A, 208/120V,3PH,4W. bus size is 1600A. area of scope 3,759sf.-------Building Permit: 18010-10000-02093-------	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76051	14041-20000-00874	19544 W TRIBUNE ST	91326	12	207B117   114	2708006012	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2014 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	01/28/2014 12:00:00 AM	ADDRESS	34.26654	-118.55905	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 5.4KW AC USING 25 MICROINVERTERS USING ENPHASE M215. STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76052	16041-20000-44903	107 N DELFERN DR	90077	5	141B157   130	4358005006	RE40-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/21/2016 12:00:00 AM			PC Info Complete	03/30/2017 12:00:00 AM	ADDRESS	34.08012	-118.42866	Plan check for power only. Upgrade service to 1200A for (E) SFD and (N) Guest House. Guest house wiring and distribution are all new. Reconnect existing SFD distribution/wiring to new service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76053	15041-20001-15275	1031 S GLENDON AVE	90024	5	132B153  1096	4363021021	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			11/16/2015 12:00:00 AM			PC Approved	11/16/2015 12:00:00 AM	ADDRESS	34.06193	-118.44439	Change to approved set to plans. Changes include removes light fixtures & track light and add 1 light fixture. Changes apply to deta 4 only {{{{{{{Title 24 plan check only.  Total area = 4,490 sq. ft.  T.I. to existing commercial space.  CHange of use from retail to yoga studio.  Two new panels (<400 A new load).}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76054	19041-10000-44566	100 1/2 S VERMONT AVE	90004	13	138B197   906	5501012023	C2-1	Central	Wilshire	Rampart Village		2111.22	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	12/16/2019 12:00:00 AM		Permit Finaled	07/07/2020 12:00:00 AM	PIN	34.07262079	-118.29129129	Energy plan check for a T.I. Scope includes new lighting and equipment with a total lighting area of 825-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76055	17041-10000-05486	6750 N BALBOA BLVD	91406	6	180B133    13	2231019022	C2-1VL-RIO, R1-1-RIO, R1P-1VL-RIO, RD2-1-RIO	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.01	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	03/22/2017 12:00:00 AM	ADDRESS	34.19346	-118.50091	PC FOR T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES. AFFECTED AREA (OUTDOOR) 23250 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76056	16041-20000-11376	9251 W NIGHTINGALE DR	90069	4	150B169  1329	5561007013	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			04/01/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Expired	05/14/2018 12:00:00 AM	ADDRESS	34.10376	-118.39047	"""$0 permit fees due to senate bill 1222""Plan check for a PV1 roof-mounted PV system. System size is 14.2 kWac and consists of (66) modules, (66) micro-inverters, and (1) load center."	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76057	11041-10000-11470	15303 W VENTURA BLVD	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM			PC Approved	08/25/2011 12:00:00 AM	ADDRESS	34.15413	-118.46661	TITLE 24 AND EMERGENCY LIGHTING IN A HI RISE BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76058	18041-20001-48892	14543 W VENTURA BLVD	91403	4	166-5A151  96	2265010005	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM			PC Approved	01/23/2019 12:00:00 AM	ADDRESS	34.15133	-118.45015	Revisions to approved plans.  Lighting system redesign.  (((PLAN CHECK FOR TITLE 24 ONLY FOR RETAIL SCOPE OF WORK INCLUDES 2243 SQFT AREA CHANGE OF USE OF EXISTING RETAIL SALES & RESTAURANT TO RESTAUARANT. INTERIOR TENANT IMPROVEMENTS.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76059	18041-10000-40946	444 S SAN VICENTE BLVD 800.2M	90048	5	138B169   208	4334006008	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			10/25/2018 12:00:00 AM	07/31/2019 12:00:00 AM		Permit Finaled	10/18/2019 12:00:00 AM	ADDRESS	34.07021	-118.37547	Inside the Mark GoodSON Bldg,  Install new X-ray equipment to replace existingequipment  and interior remodel. No change of occupancy.Plan check is for Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76060	16041-20000-24905	23704 S MAIDSTONE PL	90710	15	042B193   471	7439005025	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.01	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	07/15/2016 12:00:00 AM		Permit Finaled	09/16/2016 12:00:00 AM	ADDRESS	33.81058	-118.30528	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3.9 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76061	19041-10000-29509	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	04/28/2020 12:00:00 AM	ADDRESS	34.01366	-118.28294	"PKG #5 - DELTA ""23"" CHANGES ONLY. REPLACE THE PRESTYLE FEEDER FROM NORMAL TO EMERGENCY POWER. INSTALL NEW OUTLETS ALONG THE NORTH SIDE OF FIELD (ALONG THE BOWL) FOR WIFI/DAS CONNECTION FED FROM FOUR NEW PANELS."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76062	14041-20000-09055	12746 W JEFFERSON BLVD #1100	90094	11	102B161  1229	4211033053		West Los Angeles				2756.01	Electrical	Electrical	Commercial			04/24/2014 12:00:00 AM	09/03/2014 12:00:00 AM		Permit Finaled	06/01/2015 12:00:00 AM	ADDRESS	33.97756	-118.41709	First time tenant (Whole Foods Supermarket) for the core ans shell building. Install panels, transformers, branch circuits and lighting.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76063	16041-30000-18527	4521 S CIMARRON ST	90062	8	111B189   531	5015025032	R2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2324.00	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2016 12:00:00 AM	06/08/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.00208	-118.31617	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) panels. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76064	13041-20000-26325	1205 W 3RD ST	90026	1	132A209    95	5152013019	CW	Central	Westlake	Downtown Los Angeles		2080.00	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	12/11/2013 12:00:00 AM	PIN	34.05699675	-118.25804943	New restaurant.  Load is less than 400 amps.  Change to lighting and loads.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76065	15041-10000-20827	1925 S CENTURY PARK EAST SUITE 470	90067	5	132B161    25	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	34.06066	-118.41426	T-24 TO AN EXISTING OFFICE BUILDING, PLAN CHECK FOR ENERGY ONLY. SCOPE OF WORK INCLUDES NEW LIGHTING TO SUITE 470. TOTAL SQ. FT. 2743.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76066	18041-10000-35649	777 S FIGUEROA ST # 390	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	09/21/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.04828	-118.26116	Tenant improvement in open and private officesPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCT CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76067	19041-10000-39255	19653 W HORACE ST	91311	12	207B117    35	2708027007	RA-1-H	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	10/09/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.26726	-118.56217	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 14.8KVA PV1 SYSTEM CONSISTING OF 47 MODULES USING MICROINVERTERS 15.745 kW DC SIZE, CONNECTED TO EXISTING 400A SERVICE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76068	17041-20000-09786	7807 N ZOMBAR AVE	91406	6	189B145   539	2222003023	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.21233	-118.4679	pv1install roof mounted pv system sized 6kw interconnected with msp.this is plan check only.  permit fees paid under application 17041-90000-09222	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76069	18041-10000-32290	23101 W SHERMAN WAY	91307	12	183B097   888	2026001907	(Q)CR-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM	08/24/2018 12:00:00 AM		Permit Closed	10/04/2018 12:00:00 AM	ADDRESS	34.20042	-118.62971	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76070	19041-10000-25377	14061 W ROSCOE BLVD BUILDING B	91402	6	192B153   770	2638037017	RD3-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1199.00	Electrical	Electrical	Commercial			07/12/2019 12:00:00 AM	07/19/2022 12:00:00 AM		Issued	07/19/2022 12:00:00 AM	ADDRESS	34.22179	-118.43948	Full plan check for a new performance arts center  (Building B). Scope of work includes new lighting and equipment and new distrubtion panels feeding several subpanels. Note Building B shares a new service (4000 A)  with a new performance arts center (Building B). Building A is under the plan check number: 19041-10000-25371 expedite fee were paid under 19041-10000-25371B# for Building A: 19010-10000-00179B# for Building B: 19010-10001-00180	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76071	17041-10000-35348	12511 W MAGNOLIA BLVD	91607	2	171B165   455	2346013058	P-1VL, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	Commercial			10/03/2017 12:00:00 AM	10/03/2017 12:00:00 AM		Issued	10/03/2017 12:00:00 AM	ADDRESS	34.16502	-118.40576	PC FOR OUTDOOR T-24, REPLACE EXISTING FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 48,175	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76072	14041-20000-05599	10523 W ASHTON AVE	90024	5	135B157   496	4326003014	[Q]R3-1	West Los Angeles	Westwood	Westwood		2656.02	Electrical	Electrical	Apartment			02/28/2014 12:00:00 AM	06/30/2014 12:00:00 AM		Permit Finaled	12/09/2015 12:00:00 AM	ADDRESS	34.0631	-118.43145	New 4-story apartment building with subterranian parking.  New 1200A service.  Plan check for power and energy.Note: Variance to separate fire alarm plans is submitted.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76073	14041-10001-18948	1231 N SAN FERNANDO ROAD	90031	1	144A217   404	5445006907	[Q]CM-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM			PC Approved	07/07/2015 12:00:00 AM	ADDRESS	34.09459	-118.231	(((7/7/2015- CHANGES MADE TO APPROVED SET. DOWNSIZING RANGE FROM 50A #6 AWG TO 40 AMP #8 AWG. RELOCATED MICROWAVE TO COUNTER. UNIT C BREAKERS REDUCED FROM 80A TO 70A.)))New 108 unit apartment and future commercial. Plan check for power and energy. 5 typical units. No methane for applicant. Plan checker to verify fees. Applicant will bring a new set of plans designed for the old 2010 energy code. Fire alarm variance has been filed already.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76074	19041-30000-19651	6015 N WOODMAN AVE	91401	2	177B157   812	2239023003	[Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	Commercial			05/23/2019 12:00:00 AM	05/23/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.17982	-118.43144	Plan check for a fire alarm system for a 3-story, 14-unit apartment building. Fire alarm consists of (1) FACP and (49) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76075	14041-10000-09167	230 W AVENUE 26	90031	1	141A221   285	5205014018	UV(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			04/16/2014 12:00:00 AM	07/03/2014 12:00:00 AM		Permit Finaled	07/14/2015 12:00:00 AM	ADDRESS	34.07911	-118.21808	pc for power and energy. 1 story. ManufacturingBLDG#14016-10000-06070: FULL BUILDING TENANT IMPROVEMENT TO CONVERT EXISTING INDUSTRIAL USE TO A MULTI-KITCHEN FOOD PREPARATION AND FOOD STORAGE T.I.GROUND FLOOR: 41,510 S.F.BASEMENT:            14,671 S.F.TOTAL:                     56,181 S.F.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76076	10041-10000-15337	260 E MANCHESTER AVE	90003	9	097-5A205 412	6041016023	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2400.10	Electrical	Electrical	Commercial			08/06/2010 12:00:00 AM			PC Info Complete	08/06/2010 12:00:00 AM	ADDRESS	33.95984	-118.26972	TI IN AN EXISTING RETAIL SPACE. EXISTING 1200AMP SERVICE AND PANELS UNDER PERMIT NUMBER 06041-10000-26188.    EXISTING LIGHTS WERE RELOCATED DUE TO RE-DESIGN OF THE FLOOR AREA. NO NEW LIGHTS WERE ADDED. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76077	13041-10000-13253	505 S VIRGIL AVE	90020	4	135B197   824	5077004028	CR-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM	05/23/2013 12:00:00 AM		Permit Finaled	03/27/2014 12:00:00 AM	ADDRESS	34.0649	-118.28724	"+ ""COMPLY WITH DEPARTMENT ORDER effective date 11/30/2009. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"". call Inspector JOE PARADISO at (213)252-3033 of GENERAL ENFORCEMENT CENTRAL.  CEIS Case Number is 339644. +NOTE: Investigation fee is minimum $400.00 or double the permitfee which ever is greater.FA REMODEL FA FOR A 3 STORY BUILDING."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76078	14041-20000-10871	20470 W NASHVILLE ST	91311	12	210B109   161	2707026019	RA-1-K	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			Plans on Hold	05/07/2014 12:00:00 AM	ADDRESS	34.26998	-118.57907	this application is redudnat. please refund/ignore	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76079	17041-20000-21264	16076 COLUMBUS LN	91343	12	192B141   234	2673019073	(T)(Q)RD6-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	06/05/2018 12:00:00 AM				pv1install roof mounted pv system sized 4.8kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76080	19041-20000-15518	4749 N ST CLAIR AVE	91607	2	168B165   578	2356035006	R1-1-RIO	South Valley	North Hollywood - Valley Village	Valley Village		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			04/26/2019 12:00:00 AM	06/21/2019 12:00:00 AM		Permit Finaled	12/14/2019 12:00:00 AM	ADDRESS	34.15689	-118.3999	Plan check for a PV1 roof-mounted PV system. System size is  7.672kW AC,  and consists of (14) micro-inverters, (28) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76081	16041-20000-09982	22320 W KITTRIDGE ST	91303	3	180B101   262	2139010009	RS-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.11	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2016 12:00:00 AM	04/05/2016 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.19134	-118.61302	Plan check for the addition of a 3 kWac PV system to an existing 5 kWac system for a total system size of 8 kWac. System addition consists of (1) inverter, (12) modules, and (1) load center. MCB is being derated.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76082	14041-10000-06919	1028 S WESTWOOD BLVD	90024	5	132B153    38	4363020008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM	05/06/2014 12:00:00 AM		Issued	05/06/2014 12:00:00 AM	ADDRESS	34.06195	-118.44516	T.I. to a retail space with new panels and circuits.  Plan check for POWER and Energy, per applicant request. (original Plan expired #11041-10000-23363)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76083	19041-30000-02100	601 S FIGUEROA ST 25th Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/17/2019 12:00:00 AM	03/11/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check for Title 24 only. Project site is an existing commercial high-rise building. Project scope is a tenant improvement to common area restroom. Total lighting area = 312 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76084	10041-10000-21155	20932 W DEVONSHIRE ST	91311	12	204B109   175	2747001048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			10/25/2010 12:00:00 AM	07/22/2011 12:00:00 AM		Permit Finaled	01/10/2012 12:00:00 AM	ADDRESS	34.25702	-118.58975	ADDITION & REMODELING; MAJOR REMODEL OF AN EXISTING MC DONALDS BUILDING INCLUDING COMPLETE DEMOLITION OF THE STRUCTURE EXCEPT FOR THE EXISTING SOUTH AND EAST WALLS AND EXISTING FLOOR SLAB, NEW WOOD-BEARING WALLS AND NEW <SEE COMMENTS>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76085	15041-20000-05794	1348 S BURNSIDE AVE	90019	10	129B177   828	5085036010	R3-1-O	Central	Wilshire	P.I.C.O.		2171.00	Electrical	Electrical	1 or 2 Family Dwelling			02/27/2015 12:00:00 AM	03/13/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.04936	-118.35417	PV1Install a roof-mounted solar array on a SFD and detached garage, interconnect with a 200A MSP.System size: 5.76kW. Ungrounded system.(24) EnPhase M250 microinverters with (24) 275W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76086	19041-10000-27893	19546 W ELKWOOD ST	91335	3	189B117   765	2105009012	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	01/03/2020 12:00:00 AM	ADDRESS	34.21265	-118.55971	PV1. NEW ROOF TOP SOLAR SYSTEM CONSIST OF 34 MODULES (TRINA SOLAR 300), OPTIMIZERS (SE P300) AND A CENRAL INVERTER (SE11400H-US). SYSTEM SIZE IS 10.2 KWdc AND 11.4KWac Note: Fees $71.99 due to California Senate Bill 1222 and AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76087	10041-10000-24222	6356 W HOLLYWOOD BLVD	90028	13	148-5A187 169	5546008020	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/06/2010 12:00:00 AM	12/06/2010 12:00:00 AM		Permit Finaled	01/12/2011 12:00:00 AM	ADDRESS	34.10144	-118.32846	Ti in an existing IVAR club. EPC is for T24 and Energy only. (permit # 10041-10000-23440 was pulled for receptacles only.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76088	16041-10000-16062	13273 W FIJI WAY	90292	11	102B153   158	4224014020	C4-1, P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Apartment			05/06/2016 12:00:00 AM	01/31/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	33.97923	-118.43569	PC FOR POWER ONLY. TI TO AN EXISTING 166 UNIT APARTMENT BUILDING. SCOPE INCLUDES ADDING 166 WASHER/DRYERS TO EACH UNIT, AND 1 NEW 800A SECTION ON EXISTING MAIN DISTRIBUTION BOARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76089	16041-20001-09098	9815 W NATIONAL BLVD 1-4	90034	5	123B165   902	4311003022	C2-1	West Los Angeles	West Los Angeles	South Robertson		2690.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Approved	06/06/2016 12:00:00 AM	ADDRESS	34.03155	-118.40025	EXPEDITE PER APPLICANT REQUESTInstall a roof-mounted solar array on a gas station canopy (over filling pumps).Interconnect with 1200A MSP.System size: 45kW (15+15+15). Ungrounded system.(180) 245W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76090	13041-10000-20258	4130 W PARVA AVE	90027	4	154-5A201 209	5592019052	RS-1	Central	Hollywood	Greater Griffith Park	YES	1882.02	Electrical	Electrical	1 or 2 Family Dwelling			07/30/2013 12:00:00 AM	07/30/2013 12:00:00 AM		Permit Finaled	10/17/2013 12:00:00 AM	ADDRESS	34.11618	-118.2833	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A STANDARD PLAN. SYSTEM SIZE IS 8.82 KW USING 36 MODULES IN 3 STRINGS. [MODULES: TRINA SOLAR # TSM-245PC/PA05 |||| INVERTER: FRONIUS IG PLUS V 10.0]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76091	18041-10000-08732	10910 W LINDBROOK DR	90024	5	132B153   323	4363023034	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			03/09/2018 12:00:00 AM	06/04/2018 12:00:00 AM		Permit Finaled	06/26/2018 12:00:00 AM	ADDRESS	34.0594	-118.44483	PC FOR TITLE 24 ENERGY ONLY FOR INTERIOR NON STRUCTURAL TI TO (E) RESTAURANT.SCOPE INCLUDES NEW PANEL, CIRCUITS AND LIGHTS IN RESTROOM. TOTAL AFFERCTED AREA 117 SQ.FT.B#18016-10000-02667	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76092	18041-20001-42786	6171 N SEPULVEDA BLVD STE. A1	91411	6	177B145   355	2242001026	M1-1L-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.11	Electrical	Electrical	Commercial			12/28/2018 12:00:00 AM			PC Approved	12/28/2018 12:00:00 AM	ADDRESS	34.18246	-118.46651	12-28-2018 Changes to an permitted set of plan, Changes include reduce feeder, panel and disconnect size. All Changes has been clouded as delta 5. Plan check only, permit covered under master.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76093	13041-10000-33688	1047 S SANTEE ST	90015	14	126A209   255	5145020009	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/04/2013 12:00:00 AM	12/04/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.038	-118.25615	PLAN CHECK FOR T24 ENERGY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW FLUORESCENT FIXTURES. 1600 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76094	17041-20002-42581	24641 W STAGG ST	91304	12	189B089   300	2017027040	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM			PC Approved	07/09/2018 12:00:00 AM	ADDRESS	34.21256	-118.65721	Revisions to approved set.  Addition of ATS to system design for transfer of power from utility to ESS for back-up panel.  (((PV1. Install roof mounted PV system sized 7.6 kW with battery back up interconnected with MSP.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76095	13041-10001-13327	5865 S CAMPUS CENTER DR BLDG 14	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/14/2013 12:00:00 AM			PC Approved	08/14/2013 12:00:00 AM	ADDRESS	33.97808	-118.40726	Plan check only. Plan check for revision to approved plans.  Isc calculation and rating per inspector correction.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76096	17041-20000-34188	6273 N OAKDALE AVE	91367	3	177B113    12	2153010002	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			09/22/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Issued	10/12/2017 12:00:00 AM	ADDRESS	34.18457	-118.56505	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 12.210 KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76097	18041-20002-45638	17044 W JERSEY ST	91344	12	207B133   105	2696021018	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2019 12:00:00 AM			PC Approved	03/22/2019 12:00:00 AM	ADDRESS	34.26751	-118.50382	changes to an approved set of plans.  changes to reflect field conditions,  modules LG360W (22).this is plan check only.((((Plan check for a PV1 roof-mounted PV system. System size is 8.12 kWdc/7.6 kWac and consists of (1) inverter and (28) modules.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76098	12041-10000-10660	415 N LOS ANGELES ST	90012	14	132A215   110	5408008905	PF-1VL	Central	Central City	Historic Cultural		2071.02	Electrical	Electrical	Commercial			05/09/2012 12:00:00 AM	10/10/2012 12:00:00 AM		Permit Closed	07/14/2017 12:00:00 AM	ADDRESS	34.05553	-118.23933	EXPANSION OF EXISTING MUSEUM ON THE 2ND FLOOR;  (APPROX. EXPANSION AREA 4,500 S.F.)  Occupant load of 571.    New transformer, panels, circuits and lighting.  Full Plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76099	15041-10000-27530	7190 W FORMOSA FUSION CT	90046	5	141B181  1716	5525003041	[Q]R3-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2015 12:00:00 AM	08/26/2015 12:00:00 AM		Issued	08/26/2015 12:00:00 AM	ADDRESS	34.08557	-118.34577	PV1, install new 2kW DC solar array on single family dwelling.(8) Microinverter: M215-60-2LL--S22-IG(8) Modules: SM-250PC8	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76100	14041-20001-16481	5014 N EAGLE VIEW CIR	90041	14	162A221   180	5682020015	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2014 12:00:00 AM			PC Approved	07/17/2014 12:00:00 AM	ADDRESS	34.13801	-118.21872	Modification to approved set to match existing field conditions - no main breaker existing at house MSP.  (((2.5KW roof-mounted PV1 system with a 3.8kw Solar edge SE3800A-US inverter, (10) Renesola 250w solar modules, and Solaredge Power Optimizers.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76101	19041-10000-15779	15825 W STAGG ST	91406	6	189B141   164	2206002032	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.21218	-118.47807	REPLACE INDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76102	16041-20000-35943	5200 N LANKERSHIM BLVD 8TH FLOOR	91601	2	171B173  1382	2350018079	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			10/11/2016 12:00:00 AM	10/12/2016 12:00:00 AM		Permit Finaled	01/31/2017 12:00:00 AM	ADDRESS	34.16511	-118.37448	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 8TH FLOOR.  3487 SQFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76103	19041-10000-12799	7656 S AVALON BLVD	90003	9	099B205   281	6023024005	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2395.02	Electrical	Electrical	Commercial			04/09/2019 12:00:00 AM	04/09/2019 12:00:00 AM		Issued	04/09/2019 12:00:00 AM	ADDRESS	33.96999	-118.26497	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76104	18041-10000-26193	8449 N SEPULVEDA BLVD	91343	6	192B145   230	2654027078	[Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1174.08	Electrical	Electrical	Commercial			07/13/2018 12:00:00 AM	07/13/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.22421	-118.46797	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76105	19041-10000-12062	750 N HILL ST	90012	1	135A215   384	5408020003	C2-2	Central	Central City North	Los Angeles Historic Cultural		2071.02	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/03/2019 12:00:00 AM		Permit Finaled	05/10/2019 12:00:00 AM	ADDRESS	34.06203	-118.2397	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76106	16041-10002-45686	2652 S LONG BEACH AVE EAST	90058	9	117A213   357	5117017017	M3-2	South Los Angeles	Southeast Los Angeles	South Central		2281.00	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM			PC Info Complete	04/26/2019 12:00:00 AM	ADDRESS	34.01303	-118.24279	Change to approved set for a complete change of design with new equipment from different model and manufacutre, and reducing switchboard bus rating for the whole PV2 system.  Total PV system drop from 1.68 MW to 1.33MW with (3420) modules using p850 optimizers, and (11) using (se10k & se33.3k)inverters interconnecting through a 1600 Amps service panel. CHANGES NOTED UNDER DELTA #8&9(((PV2.  Install 1.68 MW roof mounted grid tied PV system.  (5309) modules with (21) 80 kW rated central inverters.  Frameless modules.  Feed-in-tariff project.Note: $0.00 permit fee due to CA Senate Bill 1222)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76107	18041-10000-09212	4368 S AVALON BLVD	90011	9	112-5A207  49	5115011028	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			03/13/2018 12:00:00 AM	04/12/2021 12:00:00 AM		Permit Closed	11/20/2023 12:00:00 AM	ADDRESS	34.00413	-118.26502	PC for power and energy for renovations to retail with car wash facility. Scope includes installing new 1200A 120/208V service, new panels, lights, receptacles and equipment. Total area 18,843sqft. B# 18016-10000-05631.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76108	12041-10000-05895	5200 W WILSHIRE BLVD	90036	4	132B181    30	5507024010	[T][Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			03/14/2012 12:00:00 AM	06/19/2012 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.06194	-118.3435	NEW FIRE ALARM SYSTEM IN A NEW MIXED USE APT (478 UNITS) 6 stories	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76109	18041-20000-15863	14568 W VENTURA BLVD	91403	4	166-5A151 122	2276001015	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	04/30/2018 12:00:00 AM		Permit Finaled	08/31/2018 12:00:00 AM	ADDRESS	34.15113	-118.45103	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,020 sq. ft.Note: Building application has been generated under 17014-20000-01212	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76110	12041-20000-02635	12719 W SAN VICENTE BLVD	90049	11	129B141   373	4405024006	RE20-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			06/26/2012 12:00:00 AM			PC Info Complete	09/06/2012 12:00:00 AM	ADDRESS	34.05023	-118.4837	"(N) 96' x 126' 6"" 2 STORY SFD W/ATT GARAGE"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76111	17041-10000-45562	5830 W RODEO ROAD	90016	10	120B173   562	4204020243	C4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM	08/22/2018 12:00:00 AM		Permit Finaled	12/03/2019 12:00:00 AM	ADDRESS	34.02154	-118.37378	FULL PC, CHANGE OF USE OF FROM RETAIL FURNITURE TO CORE-AND-SHELL OFFICE SPACE. NEW SERVICE AT 1200 A, 277/480W, 3PH, 4W. MULTIPLE PANELS AND TRANSFORMERS. TOTAL T24 AREA: 53,476 SQ.FT (INDOOR+OUTDOOR)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76112	12041-20000-06713	609 W 7TH ST	90017	9	129A209   119	5144006028	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM	04/17/2012 12:00:00 AM		Permit Finaled	06/22/2012 12:00:00 AM	ADDRESS	34.04764	-118.25687	Add one 800A circuit breaker for future loads.  Point of supply @2000A ATS.Note: Future load equipment is not cover under this application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76113	16041-20000-09084	1383 N MURCHISON ST	90033	14	132A227    19	5202011050	(T)(Q)C1-1VL	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM	06/16/2016 12:00:00 AM		Permit Finaled	01/05/2017 12:00:00 AM	ADDRESS	34.05771	-118.197	Plan check for power and energy. Project site is an existing commercial building. Project scope is a first time tenant (coin laundry). Total lighting area = 3,694 sq. ft.Note: Electrical core and shell has been permitted under 13041-10000-19886	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76114	13041-20000-26135	3300 W BERKELEY AVE	90026	13	144A205   207	5425002001	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	09/20/2013 12:00:00 AM		Permit Expired	10/15/2015 12:00:00 AM	ADDRESS	34.0894	-118.27341	pv1 single family dwelling. total system size 3.2 kw ac using 15 modules. using enphase microinverter. standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76115	14041-10001-35575	13160 W RIVIERA RANCH ROAD	90049	11	132B137   174	4425025001	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			02/16/2017 12:00:00 AM			PC Approved	02/16/2017 12:00:00 AM	ADDRESS	34.06037	-118.49606	02/16/2017 Changes to an approved set of plan. Changes include Change from overhead service to underground Service and refeed main house with 1 feeder. Changes has been clouded as delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76116	12041-10000-14719	11111 W SANTA MONICA BLVD	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			06/25/2012 12:00:00 AM			PC Approved	06/25/2012 12:00:00 AM	ADDRESS	34.04771	-118.44481	PLAN CHECK FOR T24 ENERGY/EMERGENCY LIGHTING FOR T.I. FOR OFFICES ON 14TH & 15TH FLOORS (#1400, 1500, & 1550) OF HIGH-RISE BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76117	14041-10000-27786	12623 W MERCER ST	91331	7	213B161   641	2532019012	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			10/07/2014 12:00:00 AM	10/07/2014 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.27936	-118.40857	PV plan check  over the counter 6.6KW, 2 inverters, 30 modules Kyocera	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76118	15041-10000-10889	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	09/22/2015 12:00:00 AM		Issued	09/22/2015 12:00:00 AM	ADDRESS	33.79173	-118.23549	ADDING FEEDER TO POWER SWITCHRACK.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76119	14041-20000-04579	281 N BENTLEY CIR	90049	5	138B149    77	4366004018	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2014 12:00:00 AM			PC Info Complete	09/25/2014 12:00:00 AM	ADDRESS	34.07702	-118.45744	New 2 story SFD with basement.  New 600A service, panels, branch circuits, and optional standby generator.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76120	14041-20001-01254	16167 W ROYAL OAK ROAD	91436	5	162B141   175	2286013008	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			04/02/2014 12:00:00 AM			PC Approved	04/02/2014 12:00:00 AM	ADDRESS	34.14143	-118.48363	Modification to approved set of plans - relocation of equipment and elimination of isolation transformer from design set.  <<<PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 27KW AC. ROOF MOUNTED. TOTAL OF 90 MODULES. USING TRANSFORMERLESS INVERTER NONSTANDARD PLAN>>>.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76121	10041-10000-19514	8506 S OSAGE AVE	90045	11	096B173    97	4127024025	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM	10/13/2010 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	33.96089	-118.37861	T-24 lighting plan check for remodeled tenant space, convert into walk in coolers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76122	17041-20000-18259	407 E 120TH ST	90061	15	084B205  1139	6083029027	R3-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	Apartment			06/01/2017 12:00:00 AM			Reviewed by Supervisor	06/13/2017 12:00:00 AM	ADDRESS	33.92385	-118.26736	Plan check for solar pv system mounted on carport. System is serving 5 separate apartment buildings.(92 ) Y500i microinverters.(168 ) 280W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76123	18041-10002-00348	2509 W 76TH ST	90043	8	099B189    51	4009015014	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/04/2018 12:00:00 AM	ADDRESS	33.97107	-118.32127	PC for new 5kW battery backup. Battery to be connected to PV system under 18041-10000-00348	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76124	15041-20001-35919	555 S FLOWER ST	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/18/2015 12:00:00 AM			PC Approved	12/18/2015 12:00:00 AM	ADDRESS	34.05048	-118.25755	[[[[12/18/15 CHANGES TO T24 ENERGY. DELTA 6 AND DELTA 8 CHANGES. CHANGES ARE CLOUDED. CHANGES TO THE LIGHTING SYSTEM AND ADDITION OF NEW FIXUTURES.]]]]PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. SUITE 4400.  5759 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76125	13041-10000-31151	735 S FIGUEROA ST # 211	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/07/2013 12:00:00 AM	01/08/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.04878	-118.26079	First time tenant -victoria sectret- in commercial space, POWER AND ENERGYfIRE ALARM VARIANCE IS SUBMITTED TO SEPERATE PLAN	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76126	16041-20001-25845	1520 N CYPRESS AVE	90065	1	147A217   190	5454035036	[Q]MR1-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			08/18/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.09779	-118.23221	Title 24 plan check energy only for 2018 sq ft per inspector's request.  (((Commercial TI - install 48 plugs and (1) new 20 A ckt.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76127	13041-10001-34502	11125 W ALLEGHENY ST	91352	7	201B173    38	2538027019	RA-1-K-HPOZ	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1211.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	04/11/2014 12:00:00 AM	ADDRESS	34.25122	-118.37403	Expedited RSES plan check per applicant request.{{PV1, Install a 8.5 kw DC roof-mounted solar array system interconnect with main service panel with (2) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (34) modules[TRINA SOLAR # TSM-250PA05.18] for 1-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76128	14041-10000-28118	18603 W TOPHAM ST	91335	3	177B121   501	2127016033	M1-1-RIO, P-1-RIO	South Valley	Reseda - West Van Nuys	Tarzana		1331.00	Electrical	Electrical	Commercial			10/10/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	34.18085	-118.5386	Title 24 plan check only. Area = 5684 sq. ft.Remove HID light fixtures and replace with new flourescent fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76129	19041-10000-49009	1115 W 190TH ST	90248	15	060B197   543	7351028010	MR1-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	01/27/2020 12:00:00 AM		Permit Finaled	09/21/2020 12:00:00 AM	ADDRESS	33.85849	-118.29527	PLAN CHECK FOR A NEW FIRE ALARM SYSTEM, SCOPE OF WORK IS ONE NEW FIRE ALARM PANEL, AND 40 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76130	14041-20000-11622	226 S OCEANO DR	90049	11	132B141   366	4404033005	RS-1	West Los Angeles	Brentwood - Pacific Palisades			2640.00	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	12/11/2014 12:00:00 AM	ADDRESS	34.0588	-118.47263	PV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. MICROINVERTER M215. ADDING 20 MODULES TO EXISTING 10. SYSTEM SIZE: 9KW(20) LG 300 MODULES(20) M250 MICROINVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76131	16041-10000-07768	532 N PALISADES DR	90272	11	129B117   107	4419015025	(Q)C2-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			03/04/2016 12:00:00 AM	03/08/2016 12:00:00 AM		Permit Finaled	03/30/2016 12:00:00 AM	ADDRESS	34.04531	-118.55178	TI TO GYM. NEW LIGHTING. PC FOR T24 ENERGY ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76132	17041-10000-34395	546 W 6TH ST	90731	15	015B197   246	7451028029	C2-1	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	11/01/2017 12:00:00 AM	ADDRESS	33.73887	-118.28887	REPLACE EXISTING FIXTURES WITH LED FIXTURES- TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76133	18041-10000-35861	4308 S BROADWAY	90037	9	114A203   321	5111013004	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2318.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.0053	-118.27812	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76134	17041-10001-21976	7217 N BERNADINE AVE	91307	12	183B093    86	2027011016	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM			PC Approved	07/14/2017 12:00:00 AM	ADDRESS	34.20094	-118.6388	changes to an approved set of plans, changes are under the clouded area. scope includes the relocation of the electrical equipment and addition of the pv meter under delta 1.****rooftop solarPC FOR PV SYSTEM USING 31 MODULES. USING MICROINVERTER ENPHASE 280W.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76135	14041-10000-01534	1055 W WILSHIRE BLVD #  1500	90017	1	130-5A207 101	5143025028	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Commercial			01/17/2014 12:00:00 AM			PC Approved	01/17/2014 12:00:00 AM	ADDRESS	34.05232	-118.2629	PLANCHECK FOR T24 ENEGY. TENANT IMPROVEMENT AT SUITE #  1500  OF (E) OFFICE BUILDING . 3070 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76136	16041-20000-44064	7140 N BALBOA BLVD	91406	6	183B133   171	2225018026	CR-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/15/2016 12:00:00 AM		Permit Finaled	02/23/2017 12:00:00 AM	ADDRESS	34.20035	-118.50092	new fire alarm system 14 devices with facp	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76137	11041-10000-14699	4834 S LINCOLN BLVD	90292	11	102B153    11	4224014015	P-1, [Q]C4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	PIN	33.97861776	-118.43569411	Ti in an existing animal clinic. EPC is for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76138	13041-10001-27227	6921 S LA TIJERA BLVD	90045	11	102B173   156	4103003015	C2-1VL	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM			PC Info Complete	10/24/2013 12:00:00 AM	ADDRESS	33.97563	-118.37395	permit to be processed under 13041-10000-27227 under Inspection fees.this supplemental:changes to approved set of plans: change to single line diagram - will be using two existing services instead of the approved single service and two transformers. original plan was approved under 13041-10000-22475resubmittal description (13041-10000-27227):TI 99 cents store.  power and T24 .  plann submitted originaly under 13041-10000-22475.  orginal engineer has changed .  new submittal was requested.  service is existing for the building . new MDP panel and circuits. short circuit is based on 65000 amp.  series rated used and breakers indicated on MDP panels .  lighting is 277v step transformer is used.  charge of submittal per hour based on original submittal.  FA variance was submitted to seperate plan.  Issue permit under inspection.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76139	14041-10001-08527	9840 N WISH AVE	91325	12	201B133   188	2692014020	RA-1-H	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2014 12:00:00 AM			PC Approved	08/20/2014 12:00:00 AM	ADDRESS	34.24953	-118.50776	"8/20/2014  CHANGES TO APPROVED SET. SIZING PV BREAKER TO 80AMPS AND CHANGING DISCONNECT. PLANCHECK ONLY. "" 0 FEES DUE TO 2012 SENATE BILL NO. 1222""PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 14KWAC., LOW FEES DUE TO 2012 SENATE BILL NO. 1222"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76140	12041-10000-06698	120 S LOS ANGELES ST	90012	14	130-5A213  98	5161016027	[Q]C4-4D	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			03/23/2012 12:00:00 AM			Corrections Issued	03/23/2012 12:00:00 AM	ADDRESS	34.05092	-118.24262	Replacement of lighting fixtures and receptacles in the exercise room of an existing hotel.  24amps of load per applicant.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76141	18041-10000-24355	1360 S FIGUEROA ST	90015	14	126A205    86	5134010024	(T)(Q)C2-2-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	09/25/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.03896	-118.26891	NEW 7-ELEVEN STORE. FIRST TIME TENANT IN A HIGH RISE BULDING. FULL PLAN CHECK FOR POWER AND ENERGY.BUILDING PERMIT # 18016-10000-20724	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76142	12041-10000-29448	940 N WESTERN AVE A-E	90732	15	021B193   193	7445011015	(Q)C2-1XL	Harbor	San Pedro	Northwest San Pedro	YES	2963.00, 2964.00	Electrical	Electrical	Commercial			12/06/2012 12:00:00 AM	12/06/2012 12:00:00 AM		Permit Finaled	01/09/2013 12:00:00 AM	ADDRESS	33.75105	-118.30881	FIRE ALARM. REPLACEMENT OF FIRE ALARM PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76143	15041-30001-42264	18549 W STRATHERN ST	91335	12	189B125   270	2103009029	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2015 12:00:00 AM			PC Approved	01/14/2016 12:00:00 AM	ADDRESS	34.21577	-118.53781	Expedite fees only.     Addition of new roof mounted solar PV array on existing single family dwelling.  Total system size = 10 kWac.  Two inverter system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76144	18041-20001-07218	16444 W ROSCOE BLVD	91406	6	189B137     4	2205003906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			07/30/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	03/11/2020 12:00:00 AM	ADDRESS	34.21987	-118.49574	"07-30-2019 Changes to an approved set of plan, Changes include relocate 3000A  Main Service Board and add ATS for Future Generator, relocate panel boards on floor plan, addtion of 2 addtional load to  ""G169-G420A"" Distribution, lighting layout through out the plan. All Changes has been clouded as delta ""A"". ***********Previous Work Description***********************{{{{{{{{New Airplane Hanger and related offices in Van Nuys Airport. EPC for power and energy.}}}}}}}}}"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76145	17041-20000-02684	14132 W LEADWELL ST	91405	2	186B153   885	2217030043	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			01/26/2017 12:00:00 AM	01/26/2017 12:00:00 AM		Permit Finaled	03/01/2017 12:00:00 AM	ADDRESS	34.20389	-118.44122	PV1.  Install 7.6 kW roof mounted grid tied PV system.  (29) modules with (1) 7.6 kW rated central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76146	18041-10000-30105	1108 S GAYLEY AVE	90024	5	132B149   103	4363023027	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			08/09/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	ADDRESS	34.06002	-118.44607	PLAN CHECK FOR POWER AND ENERGY FOR - Tenant Improvement to existing Restaurant.  No Change in occupant load. - TOTAL AFFECTED AREA = 1742 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76147	12041-10000-10227	1625 S ELECTRIC AVE	90291	11	108B145  1437	4241037006	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			05/04/2012 12:00:00 AM	05/25/2012 12:00:00 AM		Permit Finaled	10/31/2012 12:00:00 AM	ADDRESS	33.99029	-118.46252	SERVICE UPGRADE FROM 100 AMP TP 600 AMP.  INSTALL 7 NEW PANELS.  RECONNECT EXISTING CIRCUITS TO NEW PANELS (TO BE VERIFIED IN THE FIELD BY INSPECTOR.)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76148	17041-20000-13879	5840 S LOS ANGELES ST	90003	9	108B205  1190	6006004054	MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			04/27/2017 12:00:00 AM	05/10/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	33.98863	-118.27041	pv2install roof mounted pv system sized 40kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76149	11041-10000-07048	1200 S CABRILLO AVE	90731	15	015B197  1440	7454022005	R4-1	Harbor	San Pedro	Central San Pedro	YES	2969.02	Electrical	Electrical	Commercial			04/08/2011 12:00:00 AM			PC Approved	04/08/2011 12:00:00 AM	ADDRESS	33.73315	-118.29441	TI IN AN EXISTING COMMERCIAL AREA. PLAN CHECK IS FOR T-24 ENERGY CALCS AND EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76150	15041-10000-00907	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			01/12/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	01/14/2016 12:00:00 AM	ADDRESS	34.17126	-118.58861	"PC FOR ENERGY T24 ONLY. REPLACE EXISTING FLOURESCENT LIGHTSIGN WITH LED LIGHTSIGNS. RETROFIT EXISTING FLUORESCENT LIGHT SIGN WITH THE NEW FACE PANEL. ADDED NEW LED SIGN CONNECT TO EXISTING POWER CIRCUIT.REFERENCE BUILDING PERMIT: 14048-10000-02685. PROPOSED 3'-9"" X 4'-10"" D/F ILLUM. POLE SIGN (9-0)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76151	10041-20000-19789	14629 W NORDHOFF ST	91402	6	198B149   557	2651009021	[T][Q]C2-1VL	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	Commercial			10/05/2010 12:00:00 AM			PC Info Complete	11/18/2010 12:00:00 AM	ADDRESS	34.23558	-118.45117	Plan check power for chapel auditorium (place of assembly)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76152	15041-20000-21803	7608 N SEPULVEDA BLVD	91405	6	186B145   139	2209034033	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/09/2015 12:00:00 AM	07/09/2015 12:00:00 AM		Permit Finaled	10/01/2015 12:00:00 AM	ADDRESS	34.20879	-118.466	Plan check Title 24 only for outdoor lighting POPEYES LOUISIANA KITCHEN. Total Outdoor lighting area: 2500sqft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76153	18041-20000-00649	806 S ROBERTSON BLVD	90035	5	135B169   195	4333015032	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.02	Electrical	Electrical	Commercial			01/08/2018 12:00:00 AM			PC Info Complete	02/07/2018 12:00:00 AM	ADDRESS	34.06257	-118.38338	Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from restaurant to medical office. Total lighting area = 1,536 sq. ft.Note: Building application has been generated under 17016-20000-30984	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76154	19041-10001-25113	5552 W CENTURY BLVD	90045	11	090B173   137	4129029022	C2-2-CPIO	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	07/24/2019 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	33.94522	-118.37789	supplement to an approved set 19041-10001-25113, T-24 only change under delta 4. change include replacing SCD linear LED lights with 2X2 fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76155	16041-20000-28115	3611 N VERDUGO ROAD	90065	7	154-5A217 213	5457028009	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			08/09/2016 12:00:00 AM	08/24/2016 12:00:00 AM		Permit Finaled	04/06/2017 12:00:00 AM	ADDRESS	34.11679	-118.23358	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76156	16041-10000-01624	705 W MAC ARTHUR AVE	90731	15	021B197   748	7448005013	R1-1XL	Harbor	San Pedro	Central San Pedro	YES	2965.00	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Finaled	05/31/2016 12:00:00 AM	ADDRESS	33.75069	-118.29268	PV1, ROOF MOUNTED SOLAR SYSTEM. (8) MODULES AND (1) INVERTER-3.0KW.  TOTAL SIZE IS 3.0KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76157	18041-10000-19948	30 E DUDLEY AVE	90291	11	109-5A141 118	4286021009	RD1.5-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Public Safety Only			05/30/2018 12:00:00 AM	05/30/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	33.99444	-118.47891	PC FOR A NEW FIRE ALARM SYSTEM FOR A COMMERCIAL BUILDING. SCOPE INCLUDES 55 FA DEVICES, AND 2 FA PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76158	14041-10001-03079	3411 N WOODCLIFF ROAD	91403	4	159B145   465	2279025005	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM			PC Approved	04/23/2014 12:00:00 AM	ADDRESS	34.13207	-118.46209	Expedited RSES plan check per applicant request.{{PV1, Install 9.5 KW DC roof-mounted solar array on a 1-story home, interconnect with existing service panel.(2)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(38) Modules: TRINA SOLAR TSM-250PA05.18}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76159	16041-10000-24897	3960 W WILSHIRE BLVD 502-503	90010	10	132B193    72	5092030024	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2126.10	Electrical	Electrical	Commercial			07/15/2016 12:00:00 AM			PC Approved	07/15/2016 12:00:00 AM	ADDRESS	34.06153	-118.31323	TI/ TITLE 24 ( NO CHANGE OF USE) FOR OFFICE SUITE #502/503 AND HALLWAY (ENERGY ONLY). 5TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76160	18041-20000-28176	"9254 N WINNETKA AVE BLDG "" C"""	91311	12	198B113   131	2761001072	(T)(Q)CM-1-MPR, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/26/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Closed	08/10/2021 12:00:00 AM	ADDRESS	34.23884	-118.57087	Plan check for a fire alarm system for a 5-story mixed use building. Fire alarm system consists of (1) FACP and (496) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76161	14041-20000-18503	438 W AVENUE 45	90065	1	148-5A223 346	5465005031	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.10071	-118.21136	New roof mounted PV system with Enphase Microinverter, model M215-60-2LL.  Total system size 4.75KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76162	11041-20000-25598	8115 S AVALON BLVD	90003	9	099B205  1162	6030031028	C2-1VL	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2398.00	Electrical	Electrical	Commercial			12/01/2011 12:00:00 AM	12/01/2011 12:00:00 AM		Permit Finaled	12/16/2011 12:00:00 AM	ADDRESS	33.9651	-118.26533	Plan check for replacing existing vandalized 800A switchboard for new 800A switchboard. No change in connected load. Refeed new feeders to exiting panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76163	09041-10002-23850	20730 W PRAIRIE ST	91311	12	198B109    81	2748002048	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			03/02/2010 12:00:00 AM	03/02/2010 12:00:00 AM		Permit Finaled	03/31/2010 12:00:00 AM	ADDRESS	34.24073	-118.58534	Installation of 500 kva oxidizer on an existing (((((((((((((((((((((((((((((((((((((((((( 3-2-10   ADDITION OF TWO MOTORS AND CHANE 500 MCM TO 400 MCM))))))))))))))))))))))))))))))))))))))))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76164	10041-20000-14262	2614 W 7TH ST	90057	1	133-5A201 297			Central				2094.01	Electrical	Electrical	Public Safety Only			07/23/2010 12:00:00 AM	07/23/2010 12:00:00 AM		Permit Finaled	11/28/2011 12:00:00 AM	ADDRESS	34.05889	-118.28275	Install new fire alarm system for new 5 story apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76165	14041-10000-12051	820 S SPRING ST	90014	14	127-5A211 243	5144016047	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Closed	07/12/2016 12:00:00 AM	ADDRESS	34.04255	-118.25395	TITLE 24 FOR RESTARAUNT - Three story building tennant improvement.  Emergency lighting.total area = 844 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76166	15041-10000-22143	6121 W SUNSET BLVD # 150	90028	13	147A189    25	5546026039	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			07/13/2015 12:00:00 AM			PC Approved	07/13/2015 12:00:00 AM	ADDRESS	34.09818	-118.32309	ALTERATIONS IN A JEWELRY STOREPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76167	16041-10000-39917	1545 N AMALFI DR	90272	11	132B133   114	4425021005	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			11/10/2016 12:00:00 AM	11/10/2016 12:00:00 AM		Permit Finaled	01/16/2018 12:00:00 AM	ADDRESS	34.05928	-118.50422	Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect to existing 600 amp service panel.  Total system size = 9.5 kWac.  Microinverter system with 38 Enphase M250 microinverters.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76168	18041-10000-19429	2900 W SLAUSON AVE	90043	8	108B189  1419	4005013033	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/24/2018 12:00:00 AM		Permit Closed	10/20/2023 12:00:00 AM	ADDRESS	33.98888	-118.32466	PC FOR NEW FA SYSTEM WITH VOICE EVAC. SCOPE INCLUDES 49 DEVICES AND 2 PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76169	17041-10000-21041	9029 N RESEDA BLVD	91324	12	195B125    69	2770004008	C2-1VL, PB-1L	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.23458	-118.53634	Title 24 plan check.  Remove metal halide fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76170	13041-10000-18281	11232 N CHIMINEAS AVE	91326	12	210B125    84	2715033021	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2013 12:00:00 AM	07/11/2013 12:00:00 AM		Permit Finaled	10/10/2013 12:00:00 AM	ADDRESS	34.27512	-118.52847	INSTALLING ROOF-MOUNTED SOLAR ARRAY, INTERCONNECTING WITH EXISTING MAIN PANEL. SYSTEM SIZED AT 6.615 KW FOR A TWO-STORY HOUSE. (1) solaredge SE6000A-US. (27) TRINA TSM-245PC05} with (27) optimizers POWERBOX 250W OP250-LV-MC4SM-2NA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76171	15041-10000-36382	10700 W SANTA MONICA BLVD 200	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	01/25/2016 12:00:00 AM	ADDRESS	34.05167	-118.432	TI office , Title 24 only suite number 200	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76172	19041-10000-37736	12846 N WOODLEY AVE	91344	12	222B133   366	2605003019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2019 12:00:00 AM			Verifications in Progress	10/11/2019 12:00:00 AM	ADDRESS	34.30371	-118.5004	[EPLAN] PLAN CHEK FOR ROOF MOUNTED 9KVA PV1 SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIS-IP9K-4G-US) WITH 39 MODULES USING(REC SOLAR: REC290TP2 BLK) AND RAPID SHUTDOWN DEVICES CONNETED TO EXISTING 100A SERVICE	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76173	18041-10000-37226	659 S BROADWAY	90014	14	129A211   258	5144003040	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	03/07/2019 12:00:00 AM	ADDRESS	34.04551	-118.2533	Permit to replace existing 250 KW generator	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76174	14041-20000-33732	4454 N VAN NUYS BLVD Suite G	91403	4	168A151   295	2265014010	(Q)PB-1-RIO, C4-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			12/05/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.15243	-118.44849	Plan check for energy only. TI to existing space, changing from retail to dance studio. Modifying existing lighting system and adding new light fixtures (incl. emergency). 1,626sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76175	18041-10001-14172	9101 W LA TUNA CANYON ROAD	91352	7	198B185   199	2545024008	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2018 12:00:00 AM			PC Approved	05/08/2018 12:00:00 AM	ADDRESS	34.23661	-118.33153	EXPEDITED PER APPLICANTS REQUEST.PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM. SYSTEM SIZE: 34.3 KW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76176	10041-20001-07375	12541 W BEATRICE ST	90066	11	105B161   940	4211006026	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			01/20/2011 12:00:00 AM			PC Approved	01/20/2011 12:00:00 AM	ADDRESS	33.98116	-118.41478	PLAN CHECK ONLY FOR T24 ENERGY (GENERAL/EMERGENCY) LIGHTING.  RELOCATE LIGHTING FIXTURES ON EXISTING BUILDING TIME CLOCK. NO NEW LIGHTS. EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76177	17041-20002-12005	415 S BERENDO ST	90020	10	135B197   540	5502011024	R4-1	Central	Wilshire	Wilshire Center - Koreatown		2119.22	Electrical	Electrical	Commercial			03/16/2018 12:00:00 AM			PC Approved	03/16/2018 12:00:00 AM	ADDRESS	34.06681	-118.2943	[[[3/16/18 CHANGES TO APPROVED SET. PLANCHECK ONLY. CHANGES TO INVERTER AND LAYOUT. CHANGES ARE CLOUDED]]]]]PV2.  Install roof mounted PV system sized 40.0 kW interconnected with MSP.$0 permit fee per State Senate Bill SB 1222.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76178	17041-10000-31934	4909 W ROSEWOOD AVE	90004	4	141B193  1309	5522017011	R3-1	Central	Wilshire	Greater Wilshire		1924.20	Electrical	Electrical	Apartment			09/19/2017 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.07943	-118.31179	New 4-story, 26-unit apartment building (38,757 sf) over semi-subterranean garage with 7 typical unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76179	18041-10000-37562	3407 S MCLAUGHLIN AVE	90066	11	117B157   414	4249009015	[Q]RD1.5-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2018 12:00:00 AM	10/02/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.01669	-118.43111	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.85KWdc / 3.80KWac.(14)MODULES-CANADIAN SOLAR CS6K-275P 275W(14)OPTIMIZERS-SOLAREDGE P320(1)INVERTERS-SOLAREDGE SE3800H-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76180	10041-10000-16568	1230 E GABRIEL GARCIA MARQUEZ ST	90033	14	130-5A219 402	5173029907	RD2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.30	Electrical	Electrical	Apartment			08/24/2010 12:00:00 AM	12/13/2010 12:00:00 AM		Permit Finaled	03/07/2011 12:00:00 AM	ADDRESS	34.05036	-118.22601	Solar voltaic system installed on the roof of the building.  Consists of 5 modules, 5 A/C inverters, combiner box, and disconnect.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76181	14041-10000-29513	1950 S SAWTELLE BLVD 2nd Floor	90025	11	126B153   611	4261031031	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			10/23/2014 12:00:00 AM	10/23/2014 12:00:00 AM		Permit Expired	11/17/2016 12:00:00 AM	ADDRESS	34.04129	-118.44377	Plan check for Title 24 only. Tenant improvement for suite # 295 on the 2nd floor. Office space. Area = 2865 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76182	14041-20000-15007	11549 N LEXICON AVE	91342	7	213B169   583	2530019023	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM	06/05/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.27984	-118.3806	PV1.  Install 4.08 kW roof-mounted utility-interactive PV system.  Transformerless inverter with power optimizers (DC-DC converters).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76183	15041-10003-02260	5700 W SANTA MONICA BLVD	90038	13	144B189   691	5536017034	C2-1D	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			PC Approved	11/18/2015 12:00:00 AM	ADDRESS	34.0906	-118.31379	11-18-15Changes to an Approved set of plans addition of an Existing 100amp panel that was not added to the approved set,  to a 1200 amp switchboard. (((10.8.2015 - Plan check for changes to approved set. Remove 6 existing panels and install 6 new panels in  place of same amperage and voltage class, but with fully rated 42kAIC withstand rating. Existing breakers in panels to be changed out to match manufacturer and AIC rating of new panels.)))[Plan check for power only.  Title-24 has already been approved on master application.  Service upgrade to 1200 A with new distribution equipment.]*****Previous work description*****Plan check for energy only. First time tenant (7/11). New lighting including emergency. Total sqft. 2,260.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76184	19041-10000-15777	16303 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	04/30/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.21508	-118.48801	REPLACE INDOOR/OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76185	15041-10000-37230	707 W WILSHIRE BLVD #2150	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/04/2015 12:00:00 AM	11/04/2015 12:00:00 AM		Permit Finaled	03/21/2016 12:00:00 AM	ADDRESS	34.04893	-118.2572	ALTERATIONS IN OFFICE SPACEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76186	13041-20000-33219	8960 N SEPULVEDA BLVD	91343	7	195B145   117	2654005017	M1-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.10	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	12/05/2014 12:00:00 AM	ADDRESS	34.23366	-118.46735	PLAN CHECK FOR POWER AND ENERGY FOR NEW CAR WASH WITH 600A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76187	12041-20000-24451	12780 N SAN FERNANDO ROAD	91342	7	222B145   250	2506003014	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.30237	-118.46212	Modification to previously approved plans, electrical and lighting, for a new 3000A service for industrial building (Plant 1).  Install new switchgear, panels, equipment and lighting.  Plan check for power and energy.  Plan check to charge fees for any new equipment installed.  Review original set of plans for prior approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76188	09041-10003-18636	5555 W MELROSE AVE	90038	13	141B189     5	5534037009	[Q]M1-2D	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Commercial			11/24/2010 12:00:00 AM	11/24/2010 12:00:00 AM		Permit Finaled	11/08/2011 12:00:00 AM	ADDRESS	34.08363	-118.32191	Delta 9 and other revisions to previously approved set of plans.  See 09041-10001-18636  previously approved set of plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76189	19041-10000-13801	540 N WILMINGTON BLVD	90744	15	030B205   969	7417013034	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2948.30	Electrical	Electrical	Apartment			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	01/09/2020 12:00:00 AM	ADDRESS	33.77618	-118.27372	INSTALL 5 NEW FIRE SPRINKLER MONITORS WITH 1 FIRE PANEL FOR APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76190	17041-10000-30654	1404 N CATALINA ST	90027	13	147B197   897	5543017018	[Q]R4-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Info Complete	03/06/2018 12:00:00 AM	ADDRESS	34.09676	-118.29487	FULL PLAN CHECK (POWER AND ENERGY) FOR INTERIOR RENOVATION TO LEBANON HALL ON FLOORS 2-8. INSTALL (2) NEW DIST. BOARDA AND (9) NEW PANELS WITH CIRCUITS,  (2) XFRMS 112.5KVA AND 45KVA. TOTAL AFFECTED AREA 35,165 SQ.FT  ((B# 17016-10000-24791))Note. main service power is located in the basement, common area, with other buildings.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76191	19041-20000-06634	7248 W 90TH ST	90045	11	096B157   917	4119031014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			02/22/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	03/30/2019 12:00:00 AM	ADDRESS	33.95592	-118.42046	PLAN CHECK FOR NEW 5.04KW DC/4.48KW AC ROOF MOUNTED PV SYSTEM ON EXISTING SFD. SCOPE OF WORK INCLUDES (14) SUNPOWER 320W MODULES WITH MICRO INVERTERS, AND (2) 100A LOAD CENTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76192	18041-10000-22733	20100 S WESTERN AVE	90501	15	057B193    32	7351021038	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM	06/19/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	33.84877	-118.30902	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76193	18041-10000-09603	19771 S MAGELLAN DR	90502	15	057B197    42	7351034041	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/16/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	33.85196	-118.29307	REPLACE INDOOR-OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76194	18041-10000-24703	3411 W EXPOSITION BLVD	90018	10	120B185  1226	5044003017	C2-2D-SP	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2193.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	07/03/2018 12:00:00 AM		Permit Finaled	07/25/2018 12:00:00 AM	ADDRESS	34.02235	-118.33275	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76195	19041-10000-46622	712 N BURWOOD TER	90042	14	159A231   300	5483021015	R1-1	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1831.01	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2019 12:00:00 AM			Reviewed by Supervisor	11/15/2019 12:00:00 AM	ADDRESS	34.12846	-118.18336	[EPLAN] NEW ROOF-TOP SOLAR INSTALLATION 3.78KWdc (3.8KWac) USING 12 QP315 MODULES & SOLIVIA 3.8TL INVERTERS. ESS TESLA POWERWALL.CONNECTED TO A 225 NEW SERVICE (NEW SERVICE TO BE UNDER SEPARATE PRMIT)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76196	18041-20001-20407	2306 S WALNUT AVE	90291	11	111B149  1341	4242031018	R1V2	West Los Angeles	Venice	Venice		2737.00	Electrical	Electrical	1 or 2 Family Dwelling			06/01/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	33.99657	-118.45089	Expedite per applicant requestPlan check for battery back up with PV roof mounted system. System size: 7.6kW with 16 modules, 1 inverter(7.6kW) and 1 battery backup LG Chem Li-Ion Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76197	16041-20001-34008	340 N OXFORD AVE	90004	13	138B193   242	5521028019	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Apartment			06/28/2019 12:00:00 AM			PC Approved	06/28/2019 12:00:00 AM	ADDRESS	34.07736	-118.30783	06-28-2019 Changes to an approved set of plan, changes include replace lighting fixture with different manufacture. All Changes has been clouded. Plan check only, permit fee covered  under Master application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76198	16041-10000-44685	3682 N BARHAM BLVD (BUILDING-J)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.13972	-118.34133	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76199	19041-10000-34128	1632 W JAMES M. WOOD BLVD	90015	1	130-5A203 231	5137002035	C2-1	Central	Westlake	Westlake South		2095.20	Electrical	Electrical	Commercial			08/29/2019 12:00:00 AM	08/29/2019 12:00:00 AM		Issued	08/29/2019 12:00:00 AM	ADDRESS	34.05103	-118.27413	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76200	14041-10000-13234	7609-7611 W BEVERLY BLVD	90036	5	138B177   415	5526042014	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.07629	-118.35569	permit to be pulled at EPC counter only. Plan check for energy only. 1 story. Both are to be retail spaces. BLDG#14016-201-07420: SUPPLEMENTAL OF 14016-20000-07420 TO ADD WALL AND SPLIT TENANT SPACE INTO 2 UNITS WITH SAME USE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76201	17041-10000-34392	959 S CRENSHAW BLVD	90019	4	132B189  1054	5090034035	CR-1VL	Central	Wilshire	Greater Wilshire		2127.02	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Closed	01/09/2023 12:00:00 AM	ADDRESS	34.05495	-118.3231	REPLACE EXISTING FIXTURES WITH LED FIXTURES- TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76202	18041-10000-47357	9330 N GOTHIC AVE	91343	12	198B137   424	2676007019	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM	12/13/2018 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	34.2402	-118.4893	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 13 MODULES (Q-CELL 305) , 1 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.965KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76203	13041-20000-04071	2808 N ALTURA ST	90031	1	139-5A223 322	5204021017	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.01	Electrical	Electrical	Commercial			02/15/2013 12:00:00 AM	02/25/2013 12:00:00 AM		Permit Finaled	05/23/2013 12:00:00 AM	ADDRESS	34.07536	-118.21264	Plan check for energy and emergency lighting. Kitchen and corridors. Church of the Epiphany.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76204	18041-10000-31085	1515 W 190TH ST 2ND FLR.	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	08/16/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	33.85852	-118.30531	TI WORK ON 4,671 SF OF THE TOTAL FLOOR AREA. THIS IS PLAN CHECK FOR T24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76205	15041-10000-40505	19841 W NORDHOFF PL #118	91311	12	198B113   150	2761001092	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	05/19/2016 12:00:00 AM	ADDRESS	34.23699	-118.5659	T-24 TO A COMMERCIAL BUILDING, GYMNASIUM. SCOPE OF WORK INCLUDES REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW LED FIXTURES. TOTAL SQ. FT. 4288	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76206	14041-10001-04048	942 N YALE ST	90012	1	135A215    46	5414004006	C2-2D	Central	Central City North	Historic Cultural		2071.03	Electrical	Electrical	Commercial			05/06/2014 12:00:00 AM	05/07/2014 12:00:00 AM		Permit Finaled	02/19/2015 12:00:00 AM	ADDRESS	34.0661	-118.23918	(( ADDED 27 DEVICES TO MASTER PERMIT)))This is a two story church , new fire alarm 105 devices , 1 panel and 2 control panel.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76207	18041-10002-02329	3411 N MANDEVILLE CANYON ROAD	90049	11	150B133    65	4491006006	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			01/22/2018 12:00:00 AM			Reviewed by Supervisor	01/30/2018 12:00:00 AM	ADDRESS	34.10623	-118.50288	Fees for Tesla BatteiesPV 1, Roof Mounted solar system to a single family dwelling with AC energy storage batteries. (1) 7.6KWAC inverter, (29) modules, (2) AC tesla batteries and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76208	11041-10000-20661	1438-1446 S ELKGROVE CIR BLDG 12	90291	11	111B149   486	4243001033	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			09/30/2011 12:00:00 AM	08/17/2012 12:00:00 AM		Permit Finaled	05/12/2014 12:00:00 AM	ADDRESS	34.00116	-118.45778	LINCOLN PLACE APARTMENT PROJECT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76209	11041-10000-11447	210 E SWINFORD ST	90731	15	018B201   873	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		2962.10	Electrical	Electrical	Commercial			06/03/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	03/08/2012 12:00:00 AM	ADDRESS	33.74833	-118.27864	REPLACING AN EXISTING FIRE ALARM SYSTEM IN THE BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76210	19041-10000-50463	975-979 S CATALINA ST	90006	10	129B197    92	5078006008	R4-1	Central	Wilshire	Wilshire Center-Koreatown		2133.20	Electrical	Electrical	Apartment			12/09/2019 12:00:00 AM	03/31/2023 12:00:00 AM		Issued	03/31/2023 12:00:00 AM	ADDRESS	34.05352	-118.29496	FULL PLAN CHECK FOR A NEW APPARTMENT COMPLEX WITH A 1600A 120/208 3PH, 4W SERVICE, 1 ELEVATOR, 1200A RESIDENTIAL SWITCHBOARD, PANELS, CIRCUITS, LIGHTING, AND CONTROLS. TOTAL AFFECTED AREA IS 23,079 SQ FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76211	15041-20000-19664	515 S FIGUEROA ST Ste 1850	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/23/2015 12:00:00 AM	06/23/2015 12:00:00 AM		Permit Finaled	11/01/2016 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 4,801 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76212	14041-20000-32912	6840 N DE CELIS PL	91406	6	183B137   536	2225001***	[T][Q]RD2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	1 or 2 Family Dwelling			11/25/2014 12:00:00 AM	11/25/2014 12:00:00 AM		Permit Expired	12/20/2016 12:00:00 AM	ADDRESS	34.19497	-118.4944	PV1. CENTRAL/STRING INVERTER SYSTEMS STANDARD PLAN. SYSTEM SIZE 4.2 KW.SYSTEM IS ROOF MOUNTED SOLAR.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76213	17041-10000-09791	19191 S VERMONT AVE 4th Floor	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/28/2017 12:00:00 AM		Permit Finaled	05/22/2017 12:00:00 AM	ADDRESS	33.85656	-118.29099	4TH FLOOR CORRIDOR, ELEVATOR LOBBY AND RENOVATION ON APPROX. 2628SF INCLUDES NEW FLOORING, SINK AREA, PLUMBING FIXTURES, TOILET PARTITIONS, LIGHTING ETC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76214	16041-10001-41399	19700 W RINALDI ST	91326	12	210B117    26	2701004044	A1-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	11/09/2017 12:00:00 AM	ADDRESS	34.27455	-118.56289	Changes to approved set.  All changes clouded with delta 2.  New lighting and receptacles in four classrooms and one lecture hall.  Two new 75 kVA transformers feeding one new 225 amp subpanel each.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76215	19041-10000-03045	604 S RIMPAU BLVD	90005	4	135B185   467	5505007001	RE15-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	06/01/2019 12:00:00 AM	ADDRESS	34.06368	-118.33146	PC FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD. SYSTEM IS 10 KW AC, SCOPE OF WORK INCLUDES (37) 325W PV MODULES WITH OPTIMIZERS AND (1) SE10000H-US INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76216	16041-20000-17437	8500 S FIGUEROA ST	90003	8	097-5A201 184	6032035043	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			05/18/2016 12:00:00 AM	09/22/2016 12:00:00 AM		Permit Finaled	11/06/2017 12:00:00 AM	ADDRESS	33.96105	-118.28251	"Plan check for power only. Project site is a new commercial building (building for school use). Work includes a new 800-amp service and associated distribution equipment.Note: Building application has been created under 16010-10000-00537""COMPLY WITH DEPARTMENT ORDER effective date 01/21/2016. PERMIT WILL EXPIRE 30DAYS FROM ISSUANCE DATE."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76217	18041-10000-40741	8879 W PICO BLVD	90035	5	132B169   809	4332011013	C4-1VL-O	Central	Wilshire	South Robertson		2170.01	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Issued	10/24/2018 12:00:00 AM	ADDRESS	34.05526	-118.38542	Energy plan check for a restaurant T.I. Scope includes new lighting and equipment with a total area of 1167-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76218	14041-20001-00739	12064 N WOOD RANCH ROAD	91344	12	216B129    85	2601068006	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			01/10/2014 12:00:00 AM			PC Approved	01/18/2014 12:00:00 AM	ADDRESS	34.29055	-118.52513	(((EXPEDITE FEES)))PV1 TRANSFORMERLESS SYSTEM. SOLAR OPTIMIZER USED. TOTAL SYSTEM SIZE 6.0 KWAC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76219	13041-20000-27996	21001 W SHERMAN WAY	91303	3	183B105    22	2112019008	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1340.01	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.20126	-118.59094	pc for t24 energy only. new lighting. existing market. total area 6090 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76220	12041-10000-15285	5811 S SAN PEDRO ST	90011	9	108B205  1113	5101021001	MR1-1	South Los Angeles	Southeast Los Angeles			2294.10	Electrical	Electrical	Commercial			07/02/2012 12:00:00 AM	07/20/2012 12:00:00 AM		Permit Finaled	07/26/2012 12:00:00 AM	ADDRESS	33.98946	-118.2703	remodel existing offices-new luminaires and lighting controlsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76221	19041-20000-48418	233 S HOOVER ST	90004	13	136-5A201  87	5501019012	R3-1	Central	Wilshire	Rampart Village		2111.21	Electrical	Electrical	Apartment			11/22/2019 12:00:00 AM			PC Info Complete	02/14/2022 12:00:00 AM	ADDRESS	34.06946	-118.28452	800A 240/120V 3ph-4w service, distribution, power, and lighting for new building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76222	16041-30000-27220	9502 W HIGH RIDGE PL	90210	5	153B157   183	4384015019	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2016 12:00:00 AM	09/01/2016 12:00:00 AM		Permit Finaled	10/31/2016 12:00:00 AM	ADDRESS	34.11534	-118.42433	Plan check for power only. Project site is an existing single-family home. Project scope is a new 600-amp service and electrical system.Note: Building application has been pulled under 11014-20000-01206	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76223	12041-20000-01844	3909 S DENKER AVE	90062	8	117B193  1466	5036023014	RD2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2313.00	Electrical	Electrical	Apartment			01/25/2012 12:00:00 AM	03/16/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.01413	-118.30466	upgrade 20 units apartments	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76224	10041-20000-06039	788 S CENTRAL AVE bldg. A3-#88-113	90021	14	124-5A213 138	5146009003	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			04/02/2010 12:00:00 AM	04/09/2010 12:00:00 AM		Permit Finaled	12/23/2010 12:00:00 AM	ADDRESS	34.03414	-118.24273	Bldg.  A3, UNITS 88 THRU 113 ( 10 STORAGE UNITS ) LIGHTING UPGRADEENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76225	13041-20000-12467	9301 N TAMPA AVE #210	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/30/2013 12:00:00 AM	ADDRESS	34.2392	-118.55379	T24 FOR REMODEL OF RESTAURANT IN THE PATIO AREA. 431 SQRFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76226	10041-20001-05874	8151 W MELROSE AVE	90046	5	141B173   392	5528006050	C4-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			04/05/2010 12:00:00 AM			PC Approved	04/05/2010 12:00:00 AM	ADDRESS	34.08389	-118.36712	supplimental to plan check for approved plan on title 24 calc.  Revision.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76227	12041-10000-17915	9635 N ODESSA AVE	91343	12	201B137   722	2677006005	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.01	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2012 12:00:00 AM	08/22/2012 12:00:00 AM		Permit Finaled	09/04/2012 12:00:00 AM	ADDRESS	34.2457	-118.49201	Plan check for PV system. Single family dwelling. 5.886kW system. Please add new 200A panel main upgrade to inspection fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76228	14041-10000-07775	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			03/24/2014 12:00:00 AM			PC Approved	03/24/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	installation side walk 13 ea 12ft  post- supported  luminaires near the perimeter of Dodgers stadiumplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76229	19041-20000-44463	4216 W LOS NIETOS DR	90027	4	150B201   405	5591010021	R1-1	Central	Hollywood	Los Feliz	YES	1952.01	Electrical	Electrical	1 or 2 Family Dwelling			10/30/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.10897	-118.2814	PV1. INSTALL 8.25 KW DC PV SYSTEM WITH (25) MODULES/OPTIMIZERS AND (1) INVERTER(SE6000H)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76230	18041-20000-41972	2080 CENTURY PARK EAST STE 101	90067	5	132B161    39	4319001014	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	04/22/2019 12:00:00 AM		Issued	04/22/2019 12:00:00 AM	PIN	34.05920818	-118.41153897	TI to (E) medical office in commercial highrise building.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76231	12041-10000-13818	1763 W CENTURY BLVD	90047	8	091-5A193  50	6055021066	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	Commercial			06/14/2012 12:00:00 AM			PC Approved	06/14/2012 12:00:00 AM	ADDRESS	33.94562	-118.30845	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR MCDONALDS REMODEL. INDOOR AND OUTDOOR LIGHTING. LESS THAN 99 OCCUPANCY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76232	14041-10000-07076	1835 N BOLKER PL	90731	15	024B197   111	7442020004	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			03/17/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	33.76288	-118.29682	PV1, INSTALL  A 4.25 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(1) TRANSFORMERLESS INVERTER: SOLAREDGE SE3800-US-ZB-U(17)MODULES: CANADIAN SOLAR CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76233	16041-10001-36743	447 S HEWITT ST	90013	14	127-5A215 356	5163022017	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Closed	07/24/2018 12:00:00 AM	ADDRESS	34.04216	-118.23526	PC FOR CHANGES TO APPROVED SET OF PLANS. RELOCATED 2 PANELS, ADDITION OF KITCHEN EQUIPMENT AND AC UNITS. UPDATED LIGHTING AND UPDATED T24 DOCUMENTS. PERMIT TO BE ISSUED FROM THIS APP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76234	06041-10007-31275	308 E 9TH ST	90015	14	126A211   217	5145016022	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/29/2010 12:00:00 AM			PC Approved	01/29/2010 12:00:00 AM	ADDRESS	34.0397	-118.25323	Changes to approved plans.  Revise recptacle voltage, add emergency lighting, change protections size for CU units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76235	16041-20000-21970	1383 N MURCHISON ST UNIT C	90033	14	132A227    19	5202011050	(T)(Q)C1-1VL	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	02/01/2017 12:00:00 AM	ADDRESS	34.05771	-118.197	TI TO AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY. TOTAL SQUARE FOOTAGE 1182  CORE AND SHELL APPROVED UNDER APPLICATION NUMBER 13041-10000-19886	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76236	16041-20000-36856	4929 N VAN NUYS BLVD	91403	4	169-5A151  49	2263026034	C1.5-1VL-RIO, P-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1289.10	Electrical	Electrical	Commercial			10/18/2016 12:00:00 AM	10/18/2016 12:00:00 AM		Permit Finaled	11/23/2016 12:00:00 AM	ADDRESS	34.16026	-118.4489	Plan check for an elevator recall system for a parking structure. System consists of (1) FACU and (6) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76237	12041-20000-02508	11100 W SANTA MONICA BLVD 11th Floor	90025	5	129B153   877	4323027009	M2-1, M2-1VL	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			02/02/2012 12:00:00 AM			PC Approved	02/22/2012 12:00:00 AM	ADDRESS	34.04726	-118.44465	T.I. to a high rise building on 11th floor.  Install general/emergency lighting in corridor.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76238	17041-10000-24025	12060 W CREST CT	90210	2	156B165   112	2382018032	RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			07/17/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Issued	07/17/2017 12:00:00 AM	ADDRESS	34.12482	-118.40133	Install new rooftop solar system, 11.4kW AC. (50) modules with power optimizer, (1) inverter	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76239	12041-10000-08371	1411-1415 S BARRY AVE 1-25	90025	11	129B149   487	4263020026	R3-1	West Los Angeles	West Los Angeles	West Los Angeles		2674.03	Electrical	Electrical	Apartment			04/12/2012 12:00:00 AM	04/10/2013 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.04628	-118.45709	NEW  4 story, 25 units, apartment building over 1 level of subterranean garage.  <<Fire Alarm Variance is required.>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76240	17041-10000-21560	4525 W WILSHIRE BLVD	90010	4	135B185   567	5505013005	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/27/2017 12:00:00 AM	06/27/2017 12:00:00 AM		Permit Finaled	04/18/2018 12:00:00 AM	ADDRESS	34.06211	-118.32869	PC FOR FIRE ALARM COMM. LOW RISE. TOTAL  OF 88 DEVICES WITH PANEL AND POWER SUPPLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76241	17041-10000-04712	600 WORLD WAY #632	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/13/2017 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	33.9427	-118.40223	Plan check for Title 24 only for Peets Coffee T.I. at LAX Termila 6. Total area: 875 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76242	12041-20000-00058	18758 W GILMORE ST	91335	3	180B121   507	2127019001	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2012 12:00:00 AM			Corrections Issued	01/03/2012 12:00:00 AM	ADDRESS	34.18733	-118.5425	Install enphase micro inverters on roof of single family dwelling.  A variance to install Enphase Micro Inverter model M215 was submitted.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76243	17041-10000-09840	555 W 5TH ST 40TH FL.	90013	14	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC for energy only, Indoor Title 24. TI at lunch room and pantry on 40th floor on existing highrise building. Area: 1360	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76244	16041-10000-35596	5756 S ALBA ST	90058	9	108B213   623	5105009012	M3-2	South Los Angeles	Southeast Los Angeles	Central Alameda		2289.00	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	10/07/2016 12:00:00 AM		Permit Finaled	11/04/2016 12:00:00 AM	ADDRESS	33.98963	-118.23894	PC for energy only. Rmove outdoor HID fixtures and replace with new LED fixtures. Total sqft = 66821.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76245	13041-10000-29243	21860 W BURBANK BLVD BLDG B	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			10/21/2013 12:00:00 AM	01/14/2014 12:00:00 AM		Permit Finaled	05/21/2014 12:00:00 AM	ADDRESS	34.17198	-118.60379	photo voltaic roof top for a 3 story bldg,768 modules, 3 combiner boxes, 2 inverters, Roof mounted , flat roof. $0 permit fee is due to the 2012 Senate Bill No. 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76246	14041-20000-00731	16000 W VENTURA BLVD SUITE 806	91436	5	168B141   610	2283011058	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			01/10/2014 12:00:00 AM			PC Approved	01/10/2014 12:00:00 AM	ADDRESS	34.15584	-118.48164	T24 FOR EXISTING HIGHRISE OFFICE SPACE. SCOPE OF WORK ON SUITE 806	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76247	12041-10000-02651	5404 S JANDY PL	90066	11	105B161   885	4211006004	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			02/06/2012 12:00:00 AM			PC Approved	02/13/2012 12:00:00 AM	ADDRESS	33.98159	-118.41622	PLAN CHECK FOR NEW INSTALLATION OF 20KVA UPS & DEDICATED CIRCUITS FOR COMPUTER & HVAC UNIT. EXISTING PERMIT #12041-10000-01442	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76248	16041-20000-15087	1050 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	08/22/2016 12:00:00 AM		Permit Finaled	08/22/2018 12:00:00 AM	ADDRESS	33.79072	-118.29449	PV2. GROUNDMOUNTED SYSTEM. SYSTEM SIZE: 130 KW--------------------------------------------------------------------------------------------------------------------------------------ON SAME PLANS:PV2. ROOFMOUNTED SOLAR SYSTEM ON A CARPORT.  SYSTEM SIZE: 332 KW . LINE SIDE TAP.1024  MODULES BUILDING PERMIT # 16014-20000-01950 , 16010-20000-01727, 16010-20000-01728PLANS HAVE GROUNDMOUNTED SYSTEM AND CARPORT SOLAR ROOFMOUNTED SYSTEM ON SAME PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76249	17041-10000-30442	6709 W SELMA AVE	90028	13	148-5A185 275	5547014039	C4-2	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM	01/12/2018 12:00:00 AM		Permit Finaled	11/18/2019 12:00:00 AM	ADDRESS	34.09981	-118.3367	PC FOR FA SYSTEM IN APARTMENTS WITH 426 DEVICES AND SIX PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76250	14041-20000-24861	20145 W ROMAR ST	91311	12	204B113   392	2741011043	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2014 12:00:00 AM	09/16/2014 12:00:00 AM		Permit Expired	10/17/2016 12:00:00 AM	ADDRESS	34.25456	-118.57289	PV1.  Install 5.61 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76251	17041-30000-17294	7514 N HASKELL AVE	91406	6	186B141   235	2206013012	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			05/23/2017 12:00:00 AM	05/23/2017 12:00:00 AM		Permit Finaled	09/25/2018 12:00:00 AM	ADDRESS	34.20712	-118.47477	Plan check for new Fire alarm system of 6 units 2 story appartment. Total fire alarm devices: 43 devices and 1 FACP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76252	17041-20000-15671	4507 N ATOLL AVE	91423	4	165B157    64	2360027021	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			05/10/2017 12:00:00 AM	07/18/2017 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	34.15241	-118.42053	Plan check for AC coupled battery backup system. (2) 5kW Tesla Powerwall 2.0. Connected to subpanel feeding existing pv system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76253	18041-20000-41847	725 S FIGUEROA ST 7TH FLOOR	90017	14	129A207   336	5144009093	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/01/2018 12:00:00 AM	12/24/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.04886	-118.26071	Plan check for Title 24 only in existing office building T.I. full7th  floor high-rise Total area: 19703 sq ft. B#18016-10000-32997	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76254	15041-10000-36820	164 S HUDSON AVE	90004	4	138B185   380	5515005006	RE11-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/02/2015 12:00:00 AM	01/13/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.07199	-118.33325	PV1.  Install 9.765 kW DC roof-mounted, utility-interactive PV system.  (31) LG 315N1C-G4 modules and (1)  SolarEdge SE-10000A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76255	14041-10000-15782	330 N WESTLAKE AVE	90026	13	136-5A207  71	5157025043	(T)(Q)RAS4-1	Central	Westlake	Greater Echo Park Elysian		2084.02	Electrical	Electrical	Commercial			06/12/2014 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	08/21/2020 12:00:00 AM	ADDRESS	34.06951	-118.26652	PLANCHECK FOR POWER AND ENERG. 200 UNIT APARTMENT. MIXED USE. 2 SERVICES OVER 3000 AMPS EACH. FEES CALCULATED PER ENGINEER. T24 FEES NOT CHARGED PROPERLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76256	15041-10000-19211	15350 W SHERMAN WAY 3rd Flr	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.20099	-118.46808	Energy plan check for an office T.I located at the 3rd floor of a commerical building. Scope include new lighting and receptacles with existing circuits. Total area is 1612-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76257	18041-10008-01181	10165 W LA CANADA WAY	91040	7	207B181   188	2543005006	RA-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1033.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2018 12:00:00 AM			PC Info Complete	12/28/2018 12:00:00 AM	ADDRESS	34.26056	-118.35206	SUPPLEMENTAL TO APPROVED SET CHANGES ONLY DELTA 3 REMOVING TESLA CT TRANSFORMER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76258	10041-20000-13085	7806 N RESEDA BLVD	91335	12	189B125   947	2102016084	R3-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM			PC Approved	07/08/2010 12:00:00 AM	ADDRESS	34.21235	-118.53581	Fire Alarm for Reseda Church of Christ	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76259	19041-10000-05796	801 S FRIES AVE	90744	15	024B205   671	7440014904	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			02/19/2019 12:00:00 AM	02/19/2019 12:00:00 AM		Permit Finaled	11/19/2020 12:00:00 AM	ADDRESS	33.76176	-118.26404	Remodel existing 2100 SF office builidng. Install New Lights. T-24 Energy Only. Bulding Permit: 18016-40000-13604	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76260	12041-10000-17568	6056 N CORBIN AVE	91356	3	177B117   548	2153023028	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2012 12:00:00 AM	08/09/2012 12:00:00 AM		Permit Finaled	09/20/2012 12:00:00 AM	ADDRESS	34.18081	-118.56197	PLAN CHECK NEW ROOF MOUNTED 13KW PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING. PERMIT FOR PV SYSTEM AND BRANCH CIRCUIT MONITORING SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76261	11041-10000-20765	21725 W VICTORY BLVD	91303	3	180B105    77	2139004045	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			09/28/2011 12:00:00 AM			PC Approved	10/11/2011 12:00:00 AM	ADDRESS	34.18791	-118.60217	T.I. to the Prada shop within Nordstroms.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76262	17041-10000-15653	11615 W AYRES AVE APT 3	90064	11	123B153  1167	4260033***	RD1.5-1	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles		2712.00	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM	09/26/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.03164	-118.44394	PV2, INSTALLATION OF 6.175 KWdc / 5.00KWac ROOF-MOUNTED ON COMMERCIAL BUILDING(18) MODULES: SOLARCITY  STANDARD #SC325(1) INVERTER: ABB PVI-5000-OUTD-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76263	19041-10000-43687	21138 S WESTERN AVE	90501	15	051B193   190	7349014014	[Q]C2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM	03/12/2024 12:00:00 AM		Issued	03/12/2024 12:00:00 AM	ADDRESS	33.83805	-118.30891	FULL PC FOR POWER AND ENERGY. SCOPE INCLUDES NEW 1200A SERVICE/DISTRIBUTION BOARD 120/208V 3 PHASE 4 WIRE,  6 NEW PANELS,  AND NEW CIRCUITS. HAZARDOUS AREA FOR GAS DISPENSORS. TOTAL AFFECTED AREA IS 14044 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76264	19041-20000-46328	111 S MAPLETON DR	90024	5	141B153   183	4359010007	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/23/2020 12:00:00 AM		Permit Finaled	09/26/2023 12:00:00 AM	ADDRESS	34.0819	-118.43289	PLAN CHECK FOR POWER ONLY, SCOPE OF WORK INLCUDESA NEW SERVICE OF 1200 A,  NEW PANELS, EQUIPMENT, CIRCUITS, AND LIGHTING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76265	13041-20000-04728	8201 W BEVERLY BLVD	90048	5	138B173   380	5514008046	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			02/25/2013 12:00:00 AM			PC Approved	02/25/2013 12:00:00 AM	ADDRESS	34.07624	-118.36815	Plan check for energy and emergency lighting. Low-rise commercial.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76266	09041-10001-20183	701 S HILL ST 1ST & 2ND-FLOORS	90014	14	129A209   229	5144013020	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/17/2010 12:00:00 AM			PC Approved	06/17/2010 12:00:00 AM	ADDRESS	34.04582	-118.25475	addition of track lighting for floor display. permit /inspection is on going	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76267	17041-20000-29320	23700 W KIVIK ST	91367	3	171B093   365	2047004007	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		8002.04	Electrical	Electrical	1 or 2 Family Dwelling			08/17/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Permit Finaled	09/21/2017 12:00:00 AM	ADDRESS	34.16558	-118.64227	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.1 KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76268	13041-10000-34371	1033 N COLE AVE	90038	13	144B185   841	5533014901	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			12/16/2013 12:00:00 AM			PC Info Complete	04/21/2014 12:00:00 AM	ADDRESS	34.08983	-118.33006	New one story customer payment center. EPC is for power and Energy.RESUBMITTAL DUE TO PREVIOUS PC EXPIRING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76269	16041-10001-45433	5865 S CAMPUS CENTER DR	90094	11	102B161  1149	4211010102	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM			PC Approved	12/13/2017 12:00:00 AM	ADDRESS	33.97808	-118.40726	Changes to an approved set of plans, Note changes under delta 45TI, 181TI, 163TI and 1387 clouded areas. Changes include the revision of lighting and floor layout. . ****Plan check for power and Title 24, build out of a 4 level office building - Google Spruce Goose. Scope of work is under note 23 on the single line diagram.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76270	19041-10000-34104	20216 W LORENZANA DR	91364	3	171B113   157	2166040005	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center	YES	1375.01	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2019 12:00:00 AM	09/13/2019 12:00:00 AM		Permit Finaled	02/03/2020 12:00:00 AM	ADDRESS	34.16619	-118.57408	[EPLAN] PLAN CHECK FOR 2 NEW ESS(TESLA POWERWALL) CONNECTED TO EXISTING PV1 SYSTEM.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76271	14041-10001-10495	5213 MONTE VISTA ST	90042	1	151-5A227 248	5469019024	RD1.5-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park	YES	1835.20	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM			PC Approved	06/27/2014 12:00:00 AM	PIN	34.108971	-118.20081371	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 2 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (1) TRANSFORMERLESS INVERTER: SOLAREDGE # SE3000A-US-ZB-U(8) MODULES: CANADIAN SOLAR # CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76272	19041-10000-14798	2826 E 1ST ST	90033	14	126A225    37	5180014003	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2043.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.04097	-118.20394	PC FOR FA FOR MIX USE. SYSTEM INCLUDE 1 FACP AND 52 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76273	16041-10006-35308	19535 W NORDHOFF ST conduit on-ly	91324	12	198B117   257	2761035***	[T][Q]C2-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	PIN	34.2363795	-118.55851216	***** SEE APPLICATION COMMENTS********PC FOR CHANGES TO APPROVED SET UNDER DELTA 3R1 ONLY. SCOPE INCLUDES REVISION TO BREAKERS, COUNDITS AND PANELS.REVISIONS TO LOAD CALCULATIONS PER CHANGES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76274	13041-10000-15628	4900 W SUNSET BLVD	90027	13	147B197   746	5543020023	C2-CSA1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			06/13/2013 12:00:00 AM			PC Approved	06/13/2013 12:00:00 AM	ADDRESS	34.09786	-118.29626	PLAN CHECK FOR TITLE 24 PART 6 ENERGY ONLY. RECEPTACLE WORK AND LIGHTING. 375 SQUARE FEET OF LIGHTING. THERE IS NO EMERGENCY LIGHTING IN THE SCOPE OF WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76275	17041-10004-40645	3911 S FIGUEROA ST	90037	9	117A201    82	5037027915	OS-1XL	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM	02/21/2019 12:00:00 AM		Permit Closed	09/17/2019 12:00:00 AM	ADDRESS	34.01366	-118.28294	Change to approved set of plan check: Changes include modifying the single line and floor plan, all changes under delta-4 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76276	17041-10002-04590	20209 W RINALDI ST BLDG A1	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/24/2018 12:00:00 AM	08/29/2018 12:00:00 AM		Permit Finaled	03/16/2021 12:00:00 AM	ADDRESS	34.27509	-118.57388	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 9, 26, & 28. CHANGES INCLUDE REMOVING SITE LIGHTING, REVISING PANEL SCHEDULES, REVISING FLOOR PLANS, AND ADDING EQUIPMENT FOR NEW ELEVATOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76277	12041-10000-16067	7661 W MELROSE AVE	90046	5	141B177   558	5527007003	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			07/11/2012 12:00:00 AM	07/16/2012 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.08385	-118.35673	PLAN CHECK POWER AND ENERY FOR EXISTING RESTAURANT TI. MORE THAN 100 OCCUPANT.  EXISTING 400A SERVICE. NEW BRANCH CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76278	17041-10000-12206	18922 W KILFINAN ST	91326	12	219B121    41	2820003011	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	08/21/2017 12:00:00 AM	ADDRESS	34.29727	-118.54649	PC for rooftop solar with 29 LG modules, one 4KW inverter(SOLIS-4K-2G-US), one 3.6 KW inverter(SOLIS-3.6K-2G-US).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76279	18041-10000-00850	1030 N SWARTHMORE AVE SP2-108	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	04/26/2018 12:00:00 AM		Permit Finaled	09/20/2018 12:00:00 AM	ADDRESS	34.04776	-118.52525	PC FOR POWER AND ENERGY. INTERIOR REMODEL OF EXISTING RETAIL SPACE WITHIN EXISTING MALL. SCOPE INCLUDES NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 2736 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76280	17041-10001-36368	26640 S WESTERN AVE	90710	15	030B193   177	7411009024	[Q]C2-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.06	Electrical	Electrical	Commercial			12/27/2017 12:00:00 AM			PC Approved	12/27/2017 12:00:00 AM	ADDRESS	33.78015	-118.30862	Supplemental PC for changes to approved set for addition of Daylit sensors and Daylit zones. All changes clouded under delta 2.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76281	19041-20000-13883	5616 N VENTURA CANYON AVE	91401	2	174B157   553	2343011007	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.17273	-118.42891	PV1.  Install 14.76 kW DC / 11.4 kW AC roof mounted grid tied PV system.  (41) modules with 11.4 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76282	13041-10001-32863	13106 W TONOPAH ST	91331	6	195B161   627	2627020019	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			11/22/2013 12:00:00 AM			PC Approved	02/18/2014 12:00:00 AM	ADDRESS	34.22877	-118.41759	'Expedited plan check per applicant request'	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76283	16041-10001-30331	8 S CHESTER PL	90007	1	123A203   144	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.03102	-118.27718	DELTA 1 REVISIONS TO APPROVED PLANS; PERMIT WAS OBTAINED ON 17041-10000-10991.CHANGES INCLUDE NEW CIRCUITS FOR EF AND CP UNITS; ADDITIONAL LUMINAIRES; UPDATED TITLE 24 COMPLIANCE FORMS FOR INSTALLED LUMINAIRES.PLAN CHECK ONLY.(((((((((TI TO OFFICE/ MUSEUM - PC FOR T24 ENERGY ONLY FOR NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76284	15041-10002-34860	7843 N LANKERSHIM BLVD Apartment-Bld	91605	6	189B169   517	2310025034	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1218.02	Electrical	Electrical	Apartment			12/08/2017 12:00:00 AM	12/11/2017 12:00:00 AM		Permit Finaled	10/26/2018 12:00:00 AM	ADDRESS	34.21329	-118.38805	***DELTA 2 Changes to approved set:  Replace the 480V, 40 HP Elevator with a 40HP, 208 Elevator and install a 75KVA 480:208, 3ph Trasformer.======<<Full plan check for a 49 stuido units and (1) 2-bedroom unit. the site plan includes a residential building and a  2-story commercial building sharing a common underground parking. Scope includes a 5000-Amp service 120/208V 3-phase 4-wire. with 6-typical unit. total area for T-24 is 55032-SQ feet.BUILDING PERMIT #15010-10000-03727COMMERCIAL APPLICTION # : 15041-10000-35250>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76285	18041-20000-25416	1607 1/2 E PLEASANT AVE	90033	14	129A221    80	5174024026	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	10/30/2018 12:00:00 AM	PIN	34.04853509	-118.22044617	Plan check for a PV1 roof-mounted PV system. System size is 3.965 kWdc. System consists of (1) 3.3 kWac rated inverter, (13) modules, and (1) load center. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76286	19041-10000-50995	7225 N CEDAR ROAD	91405	2	183B153  1201	2217032115	(T)(Q)RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	03/20/2020 12:00:00 AM	ADDRESS	34.20208	-118.44077	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 9 MODULES (LG365Q1C) , 9 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 3.285KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76287	18041-10000-29162	1532 W CAMBRIA ST	90017	1	130-5A205 111	5142023013	R4-1	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	Commercial			08/13/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	09/25/2020 12:00:00 AM	ADDRESS	34.05255	-118.271	NEW 5 STORY MULTIFAMILY BUILDING WITH 57 UNITS, 1600 AMP SERVICE WITH 14 TYPICAL UNITS.<<<Plan Checker - Update Fees per B.H>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76288	12041-10000-30212	16960 W CALAHAN ST	91325	12	198B133   552	2687004002	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2012 12:00:00 AM			PC Info Complete	01/10/2013 12:00:00 AM	PIN	34.23677005	-118.50198719	PV1:  New 5.0 KW roof mounted PV system.  Installing 20 modules, 1 combiner box, and 1 inverter, and upgrading the service panel.  Applicant already has a permit for the project under 12041-10000-27819.  Inspector requested plan check due to the use of a combiner box.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76289	18041-10000-22630	11439 N ENCINO AVE	91344	12	213B129   333	2711022027	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.43	Electrical	Electrical	Commercial			06/18/2018 12:00:00 AM	07/10/2018 12:00:00 AM		Permit Finaled	07/11/2019 12:00:00 AM	ADDRESS	34.27848	-118.51547	Permit fee is $0.00 due to Senate Bill 1222.PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 42.24KWdc / 50.0KWac.(128)MODULES-CANADIAN SOLAR CS6U-330M(1)INVERTER-SMA SUNNY TRIPOWER CORE1	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76290	17041-10000-34999	1500 E BRIDGE ST	90033	14	130-5A221  54	5174010049	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	09/29/2017 12:00:00 AM		Permit Finaled	10/25/2017 12:00:00 AM	ADDRESS	34.05323	-118.2201	PC for T24 only for outdoor lighting. Replacing HID fixtures and replacing with new LEDfixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76291	11041-20001-11408	7101 W MELROSE AVE	90046	5	141B181   591	5525009024	C4-1VL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	04/27/2012 12:00:00 AM		Permit Finaled	05/15/2012 12:00:00 AM	ADDRESS	34.08357	-118.34448	revision to approved plans additional outlets and change service entrance from underground to overhead	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76292	13041-20001-21016	4591 N DE CELIS PL	91436	5	168B137   642	2284009042	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM			PC Approved	08/09/2013 12:00:00 AM	ADDRESS	34.15411	-118.49356	((8/6/2013 Expedite Fees))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 13.08 KW. 40 MODULES AND 2 INVERTERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76293	13041-10000-25897	22379 W CASS AVE	91364	3	171B101   531	2075006036	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1374.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2013 12:00:00 AM	09/19/2013 12:00:00 AM		Permit Expired	10/14/2015 12:00:00 AM	ADDRESS	34.16557	-118.61343	][][]CHANGES MADE TO AN EXPRESS PERMIT; ADDING 8 MODULES; SYSTEM SIZE INCREASED FROM 5.145KW DC TO 7.35KW DC IN A 2-STORY HOUSE.[][][PLAN CHECK WILL BE SUBJECTED TO FULL PLAN CHECK FEE.HOWEVER, PERMIT WILL BE SUBJECTED TO ONLY THE 8 ADDED MODULES AND 1 BRANCH CKT. EXISTING PERMIT IS UNDER 13041-20000-16577 & 13041-20001-16577. (30) TRINA - TSM-245PC05/PA05.18(1) POWER-ONE: AURORA PVI-6000-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76294	17041-20000-18691	23166 W OSTRONIC DR	91367	3	171B093   535	2042013063	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.16407	-118.63176	pv1install roof mounted pv system sized 10kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76295	13041-10000-16935	910 S FAIRFAX AVE	90036	4	132B177   328	5086007020	C2-1-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/26/2013 12:00:00 AM	07/23/2014 12:00:00 AM		Permit Finaled	08/27/2015 12:00:00 AM	ADDRESS	34.05978	-118.36284	New high school over existing basement storage level.  New 800A service and distribution system.  Power and energy plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76296	16041-10000-04998	535 W ALONDRA BLVD	90248	15	069B201   216	6120024039	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM	02/11/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	33.8856	-118.28384	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(20)MODULES-SOLARWORLD SW 275 MON BLK MODULESOPTIMIZERS-SOLAR EDGE P300 (1)INVERTER-SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76297	15041-10001-24058	1500 W PACIFIC COAST HWY Bldg D	90744	15	033B201     3	7412009009	(T)(Q)RAS3-1VL-O	Harbor	Wilmington - Harbor City	Harbor City		9800.15	Electrical	Electrical	Apartment			08/19/2015 12:00:00 AM			Reviewed by Supervisor	09/01/2015 12:00:00 AM	ADDRESS	33.79072	-118.2857	ADDITION of 18 devices for future ADA requirement.(((NEW FA SYSTEM FOR A New 3-story, 5 unit apartment with garage, Typev VA construction. 18 DEVICES. CONTROL APNEL IS IN REC  B APP# 15041-10000-24054)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76298	16041-20001-28241	6801 W HOLLYWOOD BLVD Suite 215	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			PC Approved	10/26/2016 12:00:00 AM	ADDRESS	34.10229	-118.33907	10/26/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the lighting floor plan and fixture types. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Plan check for Title 24 only. Project site is a suite within an existing commercial building. Project scope is a tenant improvement. Total lighting area = 2,712 sq. ft. Note: Building application has been generated under 16016-10000-18489	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76299	19041-10000-27053	10250 W SANTA MONICA BLVD #2870	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/16/2019 12:00:00 AM			PC Info Complete	09/16/2019 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK FOR FIRST TIME TENANT  RETIAL STORE. SCOPE INCLUDES NEW 30KVA TRANSFORMER AND EQUIPMENT CONNECTED TO EXISTING DISTRIBUTION BOARD. (PERFORMANCE METHOD) TOTAL AFFECTED AREA IS 2193 SQ.FTB# 19016-10000-21499	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76300	10041-10000-19086	3019 S FIGUEROA ST	90007	8	121-5A203 221	5123010027	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	12/09/2010 12:00:00 AM		Permit Finaled	01/31/2011 12:00:00 AM	ADDRESS	34.02477	-118.27846	TI IN RESTAURANTPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76301	16041-20000-22521	7342 N CRANER AVE	91352	2	186B173   875	2410017002	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.20	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2016 12:00:00 AM	06/27/2016 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	PIN	34.20411885	-118.36888917	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (8) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76302	17041-10000-25055	2121 S AVENUE OF THE STARS Ste #2400	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	08/22/2017 12:00:00 AM		Permit Finaled	02/15/2018 12:00:00 AM	ADDRESS	34.05554	-118.41342	PLAB CHECK FOR T24 ONLY FOR (T.I. OFFICE BUILDING, HIGH RISE, NO CHANGE OF USE, AREA, OR OCCUPANCY). TOTAL AFFECTED AREA - 6,896 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76303	19041-10000-42143	7021 N PENFIELD AVE	91306	3	183B113   369	2135009019	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	06/10/2020 12:00:00 AM	ADDRESS	34.19815	-118.56893	PV1, NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 20.440KWdc/10KWac. SCOPE OF WORK IS 36 MODULES (REC290TP2) WITH OPTIMZERS (SE P320) LEADING TO A CENTRAL INVERTER (SE10000H-US), NOTE THE MAIN BREAKER HAS BEEN DERATED.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76304	19041-10000-35096	11631 W VANOWEN ST	91605	2	183B169   545	2320010005	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			09/05/2019 12:00:00 AM	09/05/2019 12:00:00 AM		Issued	09/05/2019 12:00:00 AM	ADDRESS	34.19408	-118.38569	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76305	18041-10000-31644	6702 W HOLLYWOOD BLVD	90028	13	148-5A185 143	5547014032	C4-2D-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	10/29/2018 12:00:00 AM		Permit Finaled	12/12/2018 12:00:00 AM	ADDRESS	34.10138	-118.33635	PLAN CHECK FOR T24 ONLY, T.I. OF EXISTING RETAIL STORE FOR NEW 7-11 C-STORE. NEW CEILING TILE & LIGHT FIXTURE FOR 7-11 SPEC. NEW FLOOR TILE. NEW UNISEX RESTROM. REPLACE EXISTING RTU UNITS (1) 5-TON & (1) 7-TON. TOTAL AREA: 2,384 SQ.FT(B# 18014-10000-04758)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76306	13041-20000-19826	431 S BROADWAY	90013	14	129A211    39	5149026003	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			07/25/2013 12:00:00 AM			PC Approved	08/06/2013 12:00:00 AM	ADDRESS	34.04886	-118.25023	T24 FOR EXISTING SPACE. CHANGE OF USE FROM RETAIL TO SENIOR ACTIVITY CENTER. SCOPE OF WORK ON BASEMENT LEVEL AND GROUND LEVEL. OCCUPANT LOAD LESS THAN 99. TOTAL SQRFT 8344.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76307	19041-10000-16466	1880 N ACADEMY DR	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	9800.10	Electrical	Electrical	Commercial			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.08269	-118.24139	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76308	14041-10000-13872	2465 E 8TH ST	90021	14	123A217   304	5166006018	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	06/13/2014 12:00:00 AM		Permit Finaled	06/30/2014 12:00:00 AM	ADDRESS	34.02971	-118.22776	PC FOR POWER . ADDING NEW SERVICE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76309	11041-10000-11804	10800 W PICO BLVD # 171	90064	5	126B157   893	4255028005	[Q]C2-1D	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			06/08/2011 12:00:00 AM	07/08/2011 12:00:00 AM		Permit Finaled	08/22/2011 12:00:00 AM	ADDRESS	34.04054	-118.4272	ALTERATIONS IN EXISTING RETAIL STOREPLAN CHK IS FOR TITLE 24 ; PERMIT FEE IS IN INSPECTION FEE PERIOD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76310	13041-10000-06946	14006 W RIVERSIDE DR FC-14	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, P-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			03/18/2013 12:00:00 AM			PC Approved	03/27/2013 12:00:00 AM	ADDRESS	34.15713	-118.43792	TENANT IMPROVEMENT PLAN CHECK FOR TITLE 24 AND EMERGENCY LIGHTS FOR WESTFIELD FASHION CENTER UNIT FC-14. NOTE: ALL TITLE 24 PART 6 ENERGY LIGHTING NOTE: PERMITS SHALL BE OBTAINED THROUGHT THE ELECTRICAL PLAN CHECK COUNTER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76311	14041-20000-14146	1861 S BUNDY DR	90025	11	123B149   315	4259018011	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/28/2014 12:00:00 AM	07/24/2014 12:00:00 AM		Permit Finaled	03/20/2015 12:00:00 AM	ADDRESS	34.0352	-118.45736	T.I. to existing building.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy.Investigation fee paid under building permit	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76312	16041-30001-29272	2711 W SOUTHWEST DR	90043	8	105B189  1518	4007020014	[Q]CM-1VL	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2348.00	Electrical	Electrical	Commercial			09/15/2016 12:00:00 AM			PC Approved	09/15/2016 12:00:00 AM	ADDRESS	33.98102	-118.32297	Plan check for Title 24 only in existing space single story building T.I. Total area: 418 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76313	08041-10002-22168	448 S HILL ST 3th&4th	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles	YES	2073.01	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			Verifications in Progress	11/04/2011 12:00:00 AM	ADDRESS	34.04896	-118.25139	This is an AS BUILT aplication.  Work was completed under permit # 08041-10000-22168 that has since expired.  Some modifications were also done in the field.  Applicant is including the original approved set of plans.  All the red marks on the approved set of plans were done by the electrician out in the field.  <<<<<New work on the 3rd and 4th floor.  A variance to separate the electical and fire life safety system was submitted.  Plan checked for electrical, emergency and T24 lighting.>>>>>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76314	19041-20000-27675	8150 N ORION AVE	91406	6	192B145   617	2654038014	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			07/18/2019 12:00:00 AM	08/02/2019 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.2189	-118.47197	Plan check for Title 24 only in existing space Tenant improvement. Total area: 1716 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76315	16041-10001-04043	15909 S ORCHARD AVE	90247	15	069B197   130	6120014020	R1-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.10	Electrical	Electrical	1 or 2 Family Dwelling			03/25/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	33.88687	-118.28838	3/25/2016CHANGES TO AN APPROVED SET OF PLANS.  ADDITION OF 2 KYOCERA MODULES KU2656ZPA.PV1, rooftop solar 6.0kW AC. Standard plan is used.(28)MODULES- KU2656ZPA(1)INVERTER- PVI-6000-OUTD	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76316	19041-10000-14647	4203 W JEFFERSON BLVD	90016	10	120B181   692	5050025058	CM-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2200.00	Electrical	Electrical	Commercial			04/22/2019 12:00:00 AM	06/10/2019 12:00:00 AM		Permit Finaled	04/03/2023 12:00:00 AM	ADDRESS	34.0257	-118.34196	PC for power and energy for new Brewery and testing room. New 450A,120/240v,3ph, 4w Feeder to feed new place. total lighting area of  the scope is 2,000SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76317	19041-20000-21643	1709 W 35TH ST	90018	8	120B193   792	5041005041	C2-2D-O-CPIO	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			06/06/2019 12:00:00 AM	06/25/2019 12:00:00 AM		Permit Finaled	02/05/2024 12:00:00 AM	ADDRESS	34.02482	-118.30928	PC FOR NEW ROOF PV SYSTEM ON (E) COMMERCIAL BLDG. SYSTEM SIZE IS 38.5KW DC/35.3KW AC CEC/43.2KW AC. SCOPE OF WORK INCLUDES (100) HANWHA Q PEAK PV MODULES, AND A SE43.2KUS INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76318	15041-10000-22663	3165 W 6TH ST	90020	13	135B197   953	5077003013	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM	10/11/2016 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.06383	-118.29074	Full plan check for an Ihop Restaurant expansion T.I located in a MATHANE ZONE. Scope includes a new 600-Amp  3-phase 4-wire 120/208V service, 6-panels, 7-equipment, 97-circuits and a total of  22,197-SQ feet for T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76319	10041-10000-07882	4333 W PICO BLVD	90019	10	129B185  1023	5082022037	C4-1-O	Central	Wilshire	Olympic Park		2128.00, 2181.10	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	07/12/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	34.04821	-118.32914	TI IN AN EXISTING OFFICE AREA OF A AUTO SERVICE STATION. PLAN CHECK IS FOR TITLE 24 ENERGY CALCS ONLY. COMPLETE ELECTRICAL PLAN CHECK MAY BE REQUIRED, SUBJECT TO FIELD INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76320	17041-10000-23505	15700 W VENTURA BLVD	91436	5	168B141   677	2283006049	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	02/06/2020 12:00:00 AM	ADDRESS	34.15494	-118.47519	PC FOR A TI TO AN EXISTING MCDONALDS FOR POWER AND ENERGY. INSTALLING NEW 1000A DIST. BOARD (120/208V)SCOPE INCLUDES NEW CIRCUITS PANELS AND EQUIPMENT.TOTAL  AFFECTED AREA 7073 SQ.FT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76321	14041-10000-10116	1600 S IRVING TABOR CT	90291	11	108B145  1449	4241036906	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			04/17/2014 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	33.99013	-118.46324	New service for lighting in a parking lot.  Methane Zone hazardous location.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76322	17041-10000-13561	700 W 7TH ST G140	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Permit Finaled	09/29/2017 12:00:00 AM	ADDRESS	34.04797	-118.25815	PC FOR T24 ENERGY ONLY FOR RESTAURANT TI.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76323	10041-10000-12810	4120 W OLYMPIC BLVD	90019	10	132B189  1154	5081004022	C2-1-O	Central	Wilshire	Olympic Park		2127.00	Electrical	Electrical	Commercial			07/06/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	03/14/2011 12:00:00 AM	ADDRESS	34.05433	-118.32255	TI for Sport Club & Day Spa. New panels and circuits. Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76324	19041-10000-19732	13746 W VICTORY BLVD	91401	2	180B153  1131	2239006032	P-1VL, [Q]C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	Commercial			05/24/2019 12:00:00 AM	05/24/2019 12:00:00 AM		Permit Finaled	06/06/2019 12:00:00 AM	ADDRESS	34.18644	-118.43285	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76325	13041-10000-30050	7907 N CASABA AVE	91306	3	189B113   733	2107024064	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/05/2013 12:00:00 AM		Permit Expired	11/30/2015 12:00:00 AM	ADDRESS	34.21412	-118.57691	PV1, Install 5.25 kW DC roof-mounted photovoltaic system interconnect with service panel. Transformerless inverter: Solaredge SE5000A-US., power optimizer, and 21 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76326	13041-10000-02047	4405 S AVALON BLVD	90011	9	112-5A207  82	5109015036	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2285.00	Electrical	Electrical	Commercial			01/25/2013 12:00:00 AM			PC Info Complete	01/25/2013 12:00:00 AM	ADDRESS	34.00363	-118.26549	TI IN AN EXISTING COMMERCIAL BUILDING (EL POLLO LOCO) . PLAN CHECK FOR T-24 ENEGRY CALCS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76327	15041-10000-12023	2460 E 12TH ST STE B	90021	14	120A217   143	5168005021	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	05/19/2015 12:00:00 AM	ADDRESS	34.02255	-118.22799	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  RETROFIT EXISTING LIGHTING FIXTURES. PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76328	14041-20000-01959	14936 W HARTLAND ST	91405	6	183B149   662	2220018008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.04	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	02/20/2014 12:00:00 AM	ADDRESS	34.19517	-118.45876	PV1 MICROINVERTER NONSTANDARD PLAN. ADDING 1 STRING TO AN EXISTING SOLAR SYSTEM.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76329	18041-20001-39703	4208 N ALLOTT AVE	91423	4	165B157   924	2373009015	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1411.02	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2018 12:00:00 AM			PC Approved	11/15/2018 12:00:00 AM	ADDRESS	34.14616	-118.4281	expeditepv1instrall roof mounted pv system sized 11.5KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76330	10041-10000-08896	2590 N GLENDALE BLVD #D	90039	4	150A209   154	5438016001	C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	Commercial			05/12/2010 12:00:00 AM	09/14/2010 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.10502	-118.25933	Change of used from retail to restuarant.  Plan check for energy and power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76331	19041-10000-33622	707 W WILSHIRE BLVD SUITE 3600	90017	14	129A209    50	5144005400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/27/2019 12:00:00 AM	08/27/2019 12:00:00 AM		Permit Finaled	05/25/2020 12:00:00 AM	ADDRESS	34.04893	-118.2572	Energy plan check for an office T.I located on the 36th floor of a highrise building. Scope includes new lighiting and equipment with a total lighting area of 3,620-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76332	15041-10000-21945	6859 N HAYVENHURST AVE	91406	6	183B137   378	2225001017	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			07/10/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Issued	08/03/2015 12:00:00 AM	ADDRESS	34.19569	-118.49261	PC FOR POWER. INSTALLING PRESS MACHINES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76333	13041-20000-33085	7715 N BURNET AVE	91405	6	189B145   659	2209033057	M1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	02/20/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	34.21058	-118.46306	PC FOR T24 ENERGY ONLY. NEW LIGHTING. OUTDOOR AND INDOOR. TOTAL AREA ABOUT 55000 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76334	16041-20000-16258	1929 W PICO BLVD	90006	1	129A201   251	5136022027	CM-1	Central	Westlake	Pico Union		2098.20	Electrical	Electrical	Commercial			05/09/2016 12:00:00 AM	12/28/2016 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.0467	-118.28113	CHANGE OF USE FROM OFFICE/WAREHOUSE TO SCHOOL.  NEW 600 AMP SERVICE, PLAN CHECK FOR POWER AND ENERGY.  FIRE VARIANCE TO FILE AT LATER TIME.BUILDING APPLICATION 15014-10000-04686	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76335	17041-10000-28786	13691 N GAVINA AVE UNIT 523	91342	7	225B165     2	2580017007	(T)(Q)RD6-1, (T)(Q)RD6-1-K, A1-1-K, A1-1XL	North Valley	Sylmar	Sylmar	YES	1061.11	Electrical	Electrical	1 or 2 Family Dwelling			08/15/2017 12:00:00 AM			No Progress	08/22/2017 12:00:00 AM	ADDRESS	34.31924	-118.40195	PC for rooftop solar for new 5kW system. Installing 26 PV modules with optimizers and one central inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76336	13041-20000-10158	15410 W SHERMAN WAY	91406	6	183B145    75	2222030013	(Q)C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM			PC Info Complete	08/20/2013 12:00:00 AM	ADDRESS	34.201	-118.46889	New 314kw DC Photovoltaic System on an existing parking structure.  PV Modules will be mounted on carport structures with lighting.  Full plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76337	18041-20002-47169	12400 N WOODLEY AVE	91344	12	219B137    79	2605005010	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.45	Electrical	Electrical	1 or 2 Family Dwelling			04/23/2019 12:00:00 AM			PC Approved	04/23/2019 12:00:00 AM	ADDRESS	34.29607	-118.49338	$0 PLAN CHECK FEE DUE TO SB1222 AB1414SUPPLEMENTAL PLAN CHECK ONLY. ADDITION OF A NEW BRANCH CIRCUIT. CLOUDED DELTA E CHANGE ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76338	13041-10001-24749	20422 W CORALINE CIR	91311	12	207B109   446	2707018003	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2013 12:00:00 AM			PC Approved	10/15/2013 12:00:00 AM	ADDRESS	34.26306	-118.57883	EXPEDITED PER APPLICANTS REQUEST.PV1. INSTALL 9.8 KW DC ROOF MOUNTED SOLAR ARRAY OF 40 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS. DC UNGROUNDED WITH POWER OPTIMIZERS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76339	18041-20001-26522	1 S LMU DR	90045	11	099B157     9	4113026007	R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2765.00	Electrical	Electrical	Commercial			11/28/2018 12:00:00 AM			Not Ready to Issue	11/30/2018 12:00:00 AM	ADDRESS	33.96577	-118.42406	11/28/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta PCC. Changes have been made to reflect field conditions. Loads have been relocated and sub panels have been removed.*****Previous Work Description*****PC FOR TENANT IMPROVEMENT OF EXISTING OFFICE BUILDING FOR POWER AND ENERGY (LOYOLA UNIV).SCOPE INCLUDES NEW CONNECTED LOAD >400A. SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS AND LIGHTS. TOTAL CONNECTED AREA 20694 SQ.FT  B# 18016-10000-19140	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76340	16041-10000-13971	6500 W WILSHIRE BLVD 19TH FLR	90048	5	135B173   853	5088013029	P-1-O-HPOZ, [Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			04/21/2016 12:00:00 AM	04/21/2016 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	34.06371	-118.3703	INTERIOR TENANT IMPROVEMENT. NEW OFFICES, NEW LIGHTS FIXTURES AND CONTROLLED RECEPTACLES. NO CHANGE IN USE, OCCUPANT LOAD, OR PARKING REQUIREMENTS. PC FOR T-24 ONLY, TOTAL AREA: 17,747 SQ. FT. BRANCH CIRCUITS ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76341	16041-20000-25409	4231 S MCLAUGHLIN AVE #1-13	90066	11	111B161   388	4233007006	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.01	Electrical	Electrical	Apartment			07/19/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.00074	-118.41863	"PLANCHECK FOR POWER AND ENERGY FOR  A NEW 13 UNIT APARTMENT BUILDINGFully sprinklered 36' x 127'-7"" irreg. shaped 4 story Type III-B apartment over Type -A basement garage."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76342	19041-10000-34008	1771 W BLAKE AVE BLDG 10	90031	13	147A213   157	5442009024	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Apartment			08/28/2019 12:00:00 AM			Corrections Issued	10/02/2019 12:00:00 AM	ADDRESS	34.09655	-118.24246	10 OF 11. BLDG 10POWER PLAN CHECK FOR 1200A SERVICE IN A RESIDENTIAL PROJECT WITH MULTIPLE BUILDING AND SERVICES ON THE SAME LOT.ALL FUTURE TENANTS AND LOADS TO BE SUBMITTED SEPERATELY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76343	16041-10000-38012	1122 S LA CIENEGA BLVD	90035	5	132B173   837	5087002020	C2-1-O	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM			Corrections Issued	10/26/2016 12:00:00 AM	ADDRESS	34.05628	-118.37598	TITLE 24 PLAN CHECK.  REPAIR WATER DAMAGE ON 1ST FLOOR OF EXISTING TEMPLE.  FIRST FLOOR CONSISTS MAINLY OF OFFICES WITH RESTROOM AND CORRIDOR AREAS ALSO.  NEW LIGHTING AND RECEPTACLES.  TOTAL AREA = 4,704 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76344	15041-20000-34224	1245 S ARLINGTON AVE	90019	10	129B189   898	5081021019	R1-1-O-HPOZ	Central	Wilshire	Olympic Park		2129.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	34.04788	-118.31749	Plan check  for PV roof mounted system. System size: 3.8kW with 15 modules and 1 inverter(3.8kW). Standard plan is being use.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76345	12041-10000-29800	3667 S MCCLINTOCK AVE	90089	9	117B197     6	5039002034	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/18/2012 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	01/31/2014 12:00:00 AM	ADDRESS	34.02081	-118.29008	USC - PROVIDE POWER + LIGHTING FOR NEW CENTRAL PLANT. THE PARKING STRUCTURE A (PSA)  CENTRAL PLANT IS AN UNOCCUPIED MECHANICAL ROOM HOUSING MECHANICAL EQUIPMENT. IT PROVIDES CHILLED WATER TO BUILDINGS ON USC CAMPUS FOR AIR CONDITIONING REQUIREMENTS.  WITHIN PSA, INSTALLED ELECTRICAL GEAR WILL PROVIDE POWER TO 1250-TON CHILLERES, ASSOCIATED CHILLED WATER AND CONDENSER WATER PUMPS, VENTILATION FAN AND AC SYSTEM CONTROL AND ACCESSORIES.DESIGN POWER FROM SITE UTILITY TO CENTRAL PLANT.  ON ROOF OF PSA, PROVIDE POWER TO COOLING TOWERS, CONDENSER WATER FILTRATION, CHEMICAL WATER TREATMENT SYSTEMS AND MECHANICAL ACCESSORIESDESIGN ASSOCIATED LIGHTING SYSTEM FOR LEVEL 1 MECHANICAL AND ELECTRICAL ROOM AND LEVEL 7 COOLING TOWER YARD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76346	12041-20000-01389	5670 W WILSHIRE BLVD s.550	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			01/20/2012 12:00:00 AM	01/31/2012 12:00:00 AM		Permit Finaled	03/20/2012 12:00:00 AM	ADDRESS	34.06222	-118.35208	s.550 office t.i.Energy, emergencyFire/ Life Safety is existing to remain	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76347	14041-10000-33259	4270 S LINDBLADE DR	90066	11	111B157  1171	4232017030	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2752.00	Electrical	Electrical	Apartment			12/01/2014 12:00:00 AM	12/01/2014 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	33.99629	-118.42232	Plan check for new fire alarm system. Building is a 2-story building. System consists of (1) FACP and (60) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76348	16041-20001-18001	6860 N MCLAREN AVE	91307	12	183B097   693	2026022003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	ADDRESS	34.19549	-118.62432	PV1.  Install 12.22 kW DC roof mounted PV system.  (47) 260W modules with 11.4 kW transformerless central inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76349	10041-20000-13238	13648 W VAN NUYS BLVD	91331	7	207B157  1233	2646006024	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1045.00	Electrical	Electrical	Commercial			07/12/2010 12:00:00 AM	09/15/2010 12:00:00 AM		Permit Finaled	10/14/2010 12:00:00 AM	ADDRESS	34.26002	-118.43009	Lighting and power in restaurant. Title 24 energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76350	16041-20000-33400	14120 W MAGNOLIA BLVD A	91423	4	171B153   455	2248022039	C1-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			09/20/2016 12:00:00 AM	10/17/2016 12:00:00 AM		Permit Finaled	11/30/2016 12:00:00 AM	ADDRESS	34.16471	-118.44073	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 3,756 sq. ft.Note: Building application has been created under 16016-20000-22342	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76351	17041-10000-16991	6600 N TOPANGA CANYON BLVD 2070-B	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	05/26/2017 12:00:00 AM		Permit Finaled	07/18/2017 12:00:00 AM	ADDRESS	34.19008	-118.60565	Title 24 plan check.  Tenant improvement on existing retail space.  Relocate 250 amp panel, new 30 kVA transformer and 100 amp panel.  New lighting and receptacles.  Total area = 2,700 sq. ft.       Building permit #16016-40000-28816	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76352	17041-10002-44843	8500 N BALBOA BLVD STE. 130	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM			PC Approved	04/30/2018 12:00:00 AM	ADDRESS	34.22485	-118.50045	Changes to an approved set of plans, note changes under clouded areas. Scope of work includes the revision of lighting fixtures and lighting layout in room 1015. ((((((((PC for power and energy for TI comercial medical facility (Located in suite 130). Connecting new 600A DBA and 400A DBB to existing electrical Dist. board. Installing distribution board, new panels, 218kVA generator, two transformers, lights and receptacles.  Areas includes donor rooms for blood extraction, bone marrow collection, and labs. No patient treatment is provided in this facility. Total area is 37003sqft. B# 17016-10000-37033.))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76353	16041-20000-12667	527 1/2 E 35TH ST	90011	9	117A207   149	5120022021	R2-1	South Los Angeles	Southeast Los Angeles	South Central		2284.10	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.01511	-118.26687	PV1. ROOFMOUNTED SOLAR SYSTEM.  MICROINVERTER STANDARD PLAN. SYSTEM SIZE: 2KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76354	19041-20000-51314	1527 E NEWTON ST	90021	14	121-5A213 314	5130020011	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			12/12/2019 12:00:00 AM			PC Info Complete	12/12/2019 12:00:00 AM	ADDRESS	34.0256	-118.24251	TENANT IMPROVEMENT ADD NEW LIGHTS AND EQUIPMENTS PLAN CHECK FOR TITLE-24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76355	19041-10000-22493	1422 W 11TH ST	90015	1	129A205   312	5137024213	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	04/01/2020 12:00:00 AM	ADDRESS	34.04661	-118.27321	PLAN CHECK FOR POWER AND ENERGY FOR DIALYSIS CENTER CORE AND SHELL ONLY - NEW SERVICE SIZE IS 800A,120/240V, 3PH, 4WIRE. AREA OF SCOPE IS 13K.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76356	15041-20000-37220	6710 N ETIWANDA AVE	91335	3	180B125   168	2125018030	R1-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1327.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2015 12:00:00 AM	12/02/2015 12:00:00 AM		Permit Finaled	02/01/2016 12:00:00 AM	ADDRESS	34.19251	-118.53154	PV1. Install roof mounted PV system sized 6 kW. Interconnected with main service panel.(21) SUNEDISON F325 Modules(21) P400 Power Optimizers(1) SE6000A Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76357	12041-10000-22725	914 S HOOVER ST	90006	1	132A201   267	5136001012	C1-1	Central	Wilshire	MacArthur Park		2095.10	Electrical	Electrical	Commercial			09/24/2012 12:00:00 AM			PC Approved	09/24/2012 12:00:00 AM	ADDRESS	34.05518	-118.28409	TENANT IMPROVEMENT AT THE RICE CAKE HOUSE-NEW PANELBOARDS AND CIRCUITS-LESS THAN 400A NEW LOADPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76358	14041-20000-12378	15600 W ROSCOE BLVD	91406	6	192B141   521	2654040020	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			05/09/2014 12:00:00 AM			Reviewed by Supervisor	06/24/2014 12:00:00 AM	ADDRESS	34.2212	-118.47229	PLAN CHECK FOR ENERGY ONLY - Power under supplemental permit.Single story commercial building. Extending existing branch circuits for the installation of new lighting in a converted parking area (now a service space). Replacement of one existing panel and installation of 3 new subpanels. Emergency lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76359	15041-10001-28938	14749 W VINCENNES ST	91402	6	198B149   175	2650030006	RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.20	Electrical	Electrical	1 or 2 Family Dwelling			09/02/2015 12:00:00 AM			PC Approved	11/06/2015 12:00:00 AM	ADDRESS	34.24038	-118.45553	expedited per customer request. (((PV1 roof mouted systen for a single family home . Scope of work: (64) modules, (4) inverters: 20 kw (total), load center: 125 amps.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76360	19041-20000-17012	2255 S PROSSER AVE	90064	5	129B157  1216	4320014024	R1-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.04646	-118.42334	PLAN CHECK FOR NEW ENERGY STORAGE SYSTEM FOR EXISTING SFD WITH EXISTING PV SYSTEM. SCOPE OF WORK INCLUDES A 13.5KWH TESLA POWERWALL AND A NEW 200A SUBPANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76361	15041-20001-11892	12457 W OSPREY LANE unit 2	90094	11	102B161  1266	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/16/2015 12:00:00 AM	ADDRESS	33.97937	-118.41024	Expedite per applicant request*******Plan check for PV1 roof mounted  system 8 modules (SUNPOWER MODULES SPR-230NE-LK-D) and 1 inverter(SB3000TL -US-22)PV clearance shall  be relevent to Unit #1 of address 12457 Osprey Lane	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76362	19041-10000-15299	515 W 7TH ST GRND FLR	90014	14	129A209   147	5144004025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	05/29/2019 12:00:00 AM		Permit Finaled	08/21/2019 12:00:00 AM	ADDRESS	34.04704	-118.25593	FULL PC POWER AND ENERGY. SCOPE INCLUDE ADDING A NEW 400A PANEL WITH CONNECTED LOAD >400A. AFFECTED AREA 4,440SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76363	14041-10001-07239	11995 W BLUFF CREEK DR BLDG 5	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/27/2015 12:00:00 AM			Not Ready to Issue	06/01/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	((((4/27/2015))))CHANGES TO AN APPROVED SET OF PLANS.  ADDING 11 SENSORS PER PAGE MG 4.00.METHANE MITIGATION PLANS.  ELECTRICAL PLANCHECK APP # 13041-10000-35606.BLDG PERMIT: 13010-10000-04244	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76364	15041-10000-06669	8351 N SUNLAND BLVD	91352	6	192B173   357	2408014037	C2-1VL, R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			03/06/2015 12:00:00 AM	03/09/2015 12:00:00 AM		Permit Finaled	03/26/2015 12:00:00 AM	ADDRESS	34.22284	-118.36634	T24 only of restaurant. No new panels.  Total area = 1207 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76365	11041-10001-02204	3333 S GRAND AVE	90012	9	120A203   220	5122020026	[T][Q]M1-2	South Los Angeles	Southeast Los Angeles	South Central		2246.00	Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM	PIN	34.02146619	-118.27673832	REPLACE LIGHT FIXTURES.; plan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76366	10041-20000-03996	725 S FIGUEROA ST 7th&8th fl	90017	9	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/05/2010 12:00:00 AM	08/30/2010 12:00:00 AM		Permit Finaled	12/11/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	Ti 7th and 8th floor variance for 5th,6th ,7th and 8th floor submitted	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76367	13041-10000-27122	4239 E GLENMUIR AVE	90065	1	147A223   226	5465017002	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2013 12:00:00 AM	10/08/2013 12:00:00 AM		Permit Finaled	10/16/2013 12:00:00 AM	ADDRESS	34.09656	-118.21142	PV1.  Install 2.5 kW DC roof-mounted photovoltaic system. Transformerless inverter with SolarEdge SE3000A-US and power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76368	16041-20000-36167	2441 S SEPULVEDA BLVD	90064	5	123B153   141	4256010006	(T)(Q)C2-1-O	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	Commercial			10/12/2016 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	06/23/2020 12:00:00 AM	ADDRESS	34.0358	-118.43461	New 13-story (5 stories subterranean parking), 595-unit residential highrise with 1200A 4160V service.  Plan check for power and energy.  Building permit filed under 16010-10000-01422	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76369	14041-10000-23585	3157 N HUTTON DR	90210	5	156B157   162	4385024015	RE20-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2014 12:00:00 AM	09/11/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.12577	-118.42954	PV1 , INSTALL 13080 W DC SOLAR ARRAY ON A HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. UPGRADING SERVICE PANEL.(40) MODULES: SUNPOWEWR SPR-E20-327(2) INVERTERS:SMA SMERICA SB6000TL-US-22-240	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76370	17041-10001-12032	10250 W SANTA MONICA BLVD # 1825	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/14/2018 12:00:00 AM			PC Approved	09/14/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Plan check for a lost plan.(((Full plan check (Power+Energy) for first time tenant at Westfield Century City, Ste. 1825 ""Suite Supply"", total area 3,959 sq.ft. MS ELA33)))"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76371	19041-10000-12319	5755 W OBAMA BLVD	90016	10	120B173   502	5047002059	R4-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2201.00	Electrical	Electrical	Commercial			04/04/2019 12:00:00 AM	04/04/2019 12:00:00 AM		Permit Finaled	10/17/2019 12:00:00 AM	ADDRESS	34.02184	-118.37165	INSTALL 69 NEW FIRE ALARM DEVICES ON EXISTING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76372	16041-10000-04500	600 WORLD WAY TERM. 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	T-24, PC FOR ENERGY ONLY. TI TO EXISTING COMMERCIAL BUILDING (LAX AIRPORT) ON LEVEL 3, TERMINAL 6. SCOPE INCLUDES NEW LIGHTING FOR LEVEL 3 HOLDROOMS. TOTAL AFFECTED AREA IS 8758 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76373	18041-10002-12224	500 S MATEO ST 102	90013	14	127-5A217  67	5163018005	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/29/2019 12:00:00 AM	05/30/2019 12:00:00 AM		Permit Finaled	11/07/2019 12:00:00 AM	ADDRESS	34.04146	-118.23294	Changes to an approved set of plans. note changes on clouded areas. Scope of work includes the layout change of kitchen area, new panel and circuits. Note, Change of engineer from original plan check._____________________________________________Plan check for power and energy. Project site is an existing commercial building. Project scope is a change of use from retail to restaurant/tenant improvement. Total lighting area = 5,327 sq. ft.Note: Building application has been generated under 17014-10000-06345	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76374	10041-10000-14788	6511 W HOLLYWOOD BLVD	90028	13	148-5A187 137	5547007011	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.00	Electrical	Electrical	Commercial			07/29/2010 12:00:00 AM	08/10/2010 12:00:00 AM		Permit Finaled	11/03/2010 12:00:00 AM	ADDRESS	34.10176	-118.33138	Ti for a yogart shop. Plan check is for T24. (Permit is already exist # 10041-20000-11369)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76375	11041-10000-15167	12003 W WILSHIRE BLVD	0						BRENTWOOD				Electrical	Electrical	Commercial			07/20/2011 12:00:00 AM			PC Approved	07/20/2011 12:00:00 AM				TENANT IMPROVEMENT IN A RESTAURANTPLAN CHK IS FOR TITLE 24;	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76376	19041-20000-12031	801 S GRAND AVE Ste 750	90017	14	127-5A209 312	5144020042	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM	04/05/2019 12:00:00 AM		Permit Finaled	06/04/2019 12:00:00 AM	ADDRESS	34.04581	-118.25842	TI to (E) commercial office space in highrise building.  Plan check for energy only.Building permit under 19016-40000-05573.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76377	14041-20000-03262	770 N RIDGEWOOD PL	90038	13	141B189   102	5535004027	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2014 12:00:00 AM	03/12/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.08549	-118.3145	PV1 TRANFORMERLESS SYSTEM. USING POWER OPTIMIZERS. TOTAL SYSTEM SIZE 3.8KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76378	11041-10001-23439	20600 W VENTURA BLVD North-1-123	91364	3	171B109    72	2166013014	(T)(Q)RAS4-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1375.01	Electrical	Electrical	Apartment			10/23/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	ADDRESS	34.16715	-118.58204	IN APARTMENT UNITS, RECEPTACLES ARE ADDED AND LIGHTING FIXTURES IN BATHROOM HAVE CHANGED; OTHER ARCHITECTURAL CHANGES INSIDE SOME UNITS; SAME TYPE OF CHANGES IN THE COMMON AREAS((((((((((((North Building of a New 123 unit Apartment building with Commercial space.  1200A service for Commercial space and 2000A service for apartment space.  Building Permit is 11010-10000-01958	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76379	19041-10000-21169	6826 N LANKERSHIM BLVD	91605	2	183B169   566	2320011005	M1-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.05	Electrical	Electrical	Commercial			06/04/2019 12:00:00 AM	09/12/2019 12:00:00 AM		Issued	09/12/2019 12:00:00 AM	ADDRESS	34.19458	-118.38758	PC (power only) for a service upgrade to 800A, 120/240V,3ph,4w.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76380	19041-20000-30790	5401 W RED OAK DR	90068	4	153B193   333	5588001027	RE9-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	10/03/2019 12:00:00 AM	ADDRESS	34.11246	-118.30806	Plan check for PV roof mounted system, PV system size: 13.86KW DC, 10.0KW AC with 44 PV modules and 1 inverter(10.0KW)Fees  $70.25 due to California Seante Bill 1222 and AB 1414	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76381	15041-10000-38819	521 W 120TH ST	90044	15	084B201  1090	6088027032	RD2-1	South Los Angeles	South Los Angeles	Harbor Gateway North		2413.00	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Closed	08/09/2017 12:00:00 AM	ADDRESS	33.92385	-118.28345	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.0KW INTERCONNECTED WITH MSP.(15) KYOCERA 2656 MODULES(1) ABB PVI-3.0 INVERTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76382	16041-10000-39487	3717 S LA BREA AVE STE 104	90016	10	117B177     8	5025010001	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	Commercial			11/08/2016 12:00:00 AM			PC Info Complete	12/21/2016 12:00:00 AM	ADDRESS	34.01904	-118.35578	PC FOR POWER AND ENERGY. INTERIOR TENANT IMPROVEMENT FOR MEDICAL OFFICE,  CHANGE OF USE FROM BANK USE TO MEDICAL CLINIC, (E)MAIN SWITCHGEAR 1200A, ADDED LOAD < 400 A, TOTAL AREA 2074 SQ FT.B# 16016-10000-26840	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76383	10041-20000-25720	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/28/2010 12:00:00 AM			PC Approved	12/28/2010 12:00:00 AM	ADDRESS	34.07457	-118.37864	RELOCATE UG PULL SECTION BY DWP 4160 V TO OUTSIDE OF BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76384	14041-10003-15434	3640 W WILSHIRE BLVD elect room	90010	10	132B193    62	5093019018	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			07/27/2017 12:00:00 AM			PC Approved	07/27/2017 12:00:00 AM	ADDRESS	34.06145	-118.30446	Delta 4 Revision to permitted set of plans: In the main electrical room, meter board RDB1 is moved along the wall such that meter board RDB2 is in the center of the room and panel BL1 is moved to where RDB2  was.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76385	15041-20001-11356	23517 W WINDOM ST	91304	12	186B093   259	2027036025	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2015 12:00:00 AM			PC Approved	04/30/2015 12:00:00 AM	ADDRESS	34.20651	-118.64078	EXPEDITED PER APPLICANTS REQUESTPV1. ROOFMOUNTED SOLAR SYSTEM. NON STANDARD PLAN. SYSTEM SIZE: 16.35 KW DC	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76386	13041-20000-25084	21650 W OXNARD ST 6th floor	91367	3	177B105    83	2146006042	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			Corrections Issued	09/16/2013 12:00:00 AM	ADDRESS	34.17901	-118.60107	New offices in an existing high-rise office building on the 6th floor.  DUE TO MULTIPLE PROJECTS ON FLOORS 6-10 BY THIS ENGINEER AND WORK BY OTHERS FULL PLAN CHECK FOR LOAD GREATER THAN 400 AMPS IS LIKELY TO BE REQUIRED SUBJECT TO FIELD INSPECITON.  Load is less than 400 amps per applicant for this portion.  PLAN Check Only for Energy, with Emergency lighting.  Permit Fees are under Inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76387	15041-20000-06491	1210 N CASIANO ROAD	90049	5	141B145   180	4368007018	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.08302	-118.47084	Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (44) modules, (1) inverter, and (1) combiner box.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76388	18041-10000-47450	812 S MAIN ST	90291	11	109-5A143 397	4286012035	C2-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			01/14/2019 12:00:00 AM			PC Info Complete	02/25/2019 12:00:00 AM	ADDRESS	33.99258	-118.47418	METHANE GAS DETECTION SYSTEM FOR MIXED USE BUILDING BUILT WITH 2 LEVELS OF SUBTERRANEAN PARKING. METHANE ZONE DESIGN LEVEL 3	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76389	15041-10000-11394	8822 N BURNET AVE	91343	6	195B145   664	2654007164	(T)(Q)RD1.5-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1175.20	Electrical	Electrical	Apartment			04/16/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	12/24/2015 12:00:00 AM	ADDRESS	34.23069	-118.46313	NEW FIRE ALARM SYSTEM FOR 2 STORY WITH ONE LEVEL PARKING APARTMENT BUILDING. 65 FA DEVICES AND ONE FA PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76390	19041-10000-33119	1999 S AVENUE OF THE STARS 25th Flr	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM			PC Info Complete	08/22/2019 12:00:00 AM	ADDRESS	34.05886	-118.41642	Energy pc only for a portion of corridor space. area 152sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76391	10041-20000-15040	4228 N FIGUEROA ST	90031	1	145-5A223  78	5467003021	[Q]C2-1VL-HPOZ	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1994.00	Electrical	Electrical	Commercial			08/03/2010 12:00:00 AM	08/06/2010 12:00:00 AM		Permit Finaled	08/19/2010 12:00:00 AM	PIN	34.09419013	-118.20827414	lighting in jack in the box. energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76392	15041-10000-40756	11700 N CORBIN AVE #99	91326	12	216B113     1	2701002068		North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2015 12:00:00 AM	12/03/2015 12:00:00 AM		Permit Finaled	05/24/2016 12:00:00 AM	ADDRESS	34.28162	-118.57177	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(TRACT 50509-01_ LOT 99) TWO STORY SFD WITH ATTACH 3 CAR GARAGE_ MODEL DWELLING*STANDARD PLAN # 643 _ PLAN 1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76393	13041-20000-28124	1112 E 12TH ST 101-105	90021	14	123A211   229	5132016044	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			10/09/2013 12:00:00 AM	10/15/2013 12:00:00 AM		Permit Finaled	12/09/2013 12:00:00 AM	ADDRESS	34.03084	-118.24749	Convert a carport to a garage.  Change to lighting only.  Load is less than 400 amps.  PLAN CHECK ONLY for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76394	17041-20001-03336	1201 W 5TH ST Restrooms	90017	1	132A209   186	5152016001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			02/22/2017 12:00:00 AM	02/22/2017 12:00:00 AM		Permit Finaled	03/07/2017 12:00:00 AM	ADDRESS	34.05429	-118.25967	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is restrooms on the 1st floor. Total lighting area = 300 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76395	19041-10000-42952	1604 S PACIFIC AVE	90291	11	106-5A145   4	4238014009	C2-1-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	07/07/2020 12:00:00 AM	ADDRESS	33.98767	-118.47174	T-24 ENERGY ONLY PLAN CHECK FOR A TI. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. ALL NEW LOADS CONNECTED TO EXISTING 600A SERVICE.TOTAL AFFECTED AREA 1723 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76396	11041-10000-08860	3745 S CHESAPEAKE AVE 1-25	90016	10	117B181   104	5046034013	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.01	Electrical	Electrical	Commercial			05/02/2011 12:00:00 AM	05/02/2011 12:00:00 AM		Permit Finaled	06/13/2011 12:00:00 AM	ADDRESS	34.01868	-118.34533	REPLACEMENT OF A DAMAGED FIRE ALARM PANEL, NON-ADDRESSABLE.  ALL DEVICES ARE EXISTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76397	17041-20001-29887	26326 S PRESIDENT AVE	90710	15	033B193   712	7411024034	R1-1XL	Harbor	Wilmington - Harbor City	Harbor City	YES	2933.06	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	33.78286	-118.30386	expeditepv1install roof mounted pv system sized 2.5kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76398	15041-20000-16290	936 S OLIVE ST UNIT 253	90015	14	127-5A209 193	5139004027	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Apartment			05/29/2015 12:00:00 AM	08/04/2015 12:00:00 AM		Permit Finaled	03/11/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	Permit #8 of 20 for address 936 Olive St. Solar clearance shall apply from master permit. Master permit under #15041-20000-16259. PV2. Install roof mounted solar system sized 3.8 kW. Interconnected with main servicve panel.(11) ReneSola JC 300(1) PVI 3.8 TL Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76399	18041-10000-13610	124 W 111TH ST	90061	8	088-5A203 373	6074021015	R2-1	South Los Angeles	Southeast Los Angeles			2411.20	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Expired	10/12/2023 12:00:00 AM	ADDRESS	33.93469	-118.27479	NEW ROOFTOP SOLAR SYSTEM. CONSIST OF 12 MODULES ( CANADIANSOLAR CS6K 275W), OPTEMIZERS (SOLAREDGE POWER OPTIMIZERS 320) WITH A CENTRAL INVERTER (SOLAR EDGE SE3000H-US).  SYSTEM SIZE IS  3.3 KWdc AND 3 KWac.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76400	17041-10000-02255	10053 N BARTEE AVE	91331	6	204B153   778	2645011026	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM	01/24/2017 12:00:00 AM		Permit Finaled	06/19/2017 12:00:00 AM	ADDRESS	34.2533	-118.43531	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.625KWdc / 6.0KWac.(25)MODULES-AXITEC AXIPOWER AC-265P/156-60S (1)INVERTER-FRONIUS PRIMO 6.0	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76401	15041-20000-36994	9504 N WHITAKER AVE	91343	12	198B133    42	2686020009	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2015 12:00:00 AM	11/17/2015 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.24325	-118.499	PV1, roof mounted solar 12.7kW AC(44)modules: SPR-327NE-WHT-D(1)inverter: SunnyBoy 5000TL-US(1)inverter: SunnyBoy 7700TL-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76402	15041-10001-39684	10250 W SANTA MONICA BLVD MACYS	90067	5	132B161    24	4319003066	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/23/2016 12:00:00 AM	01/20/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR CHANGES TO APPROVED SETSCOPE INCLUDES NEW  DIST.BOARDS AND CHANGES TO EMERGENCY POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76403	19041-10000-11361	3109 W OLYMPIC BLVD	90006	10	129B193   270	5080024026	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2132.01	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	03/29/2019 12:00:00 AM		Permit Finaled	09/06/2019 12:00:00 AM	ADDRESS	34.05277	-118.3036	Remove HID fixtures and replace with new LED fixtures (Outdoor only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76404	15041-10000-10900	1926 W ADAMS BLVD	90018	8	123B193   633	5053012005	C1-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	Commercial			04/13/2015 12:00:00 AM	04/15/2015 12:00:00 AM		Permit Finaled	05/13/2015 12:00:00 AM	ADDRESS	34.03251	-118.30697	TI TO AN EXISTING SINGLE STORY BUILSING.  ADDING NEW LIGHTING AND NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOTAGE 6250.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76405	13041-10001-34191	2800 W BEVERLY BLVD	90057	13	138A203   482	5155014021	C2-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Commercial			12/09/2013 12:00:00 AM			Corrections Issued	12/15/2013 12:00:00 AM	ADDRESS	34.07025	-118.27894	Expedited RSES plan check per applicant request.(((( PV2, Installing a 30 KW DC roof-mounted solar array system for commercial building. (120)modules: Canadian Solar CS6P-250P: 250W, PTC-227. (3 )Transformered Inverters: Fronious 10.03 String inverter).))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76406	13041-20000-13251	10270 W ALMAYO AVE	90064	5	129B161   275	4315014001	R3-1-O	West Los Angeles	West Los Angeles	Westside		2679.02	Electrical	Electrical	Apartment			05/21/2013 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.04948	-118.41336	NEW CONSTRUCTION OF 33 UNIT APARTMENT COMPLEX. PC FOR POWER AND ENERGY. FIRE ALARM VARIANCE HAS BEEN FILED(((LOCATION IS IN METHANE ZONE. NEW CONSTRUCTION HAZARDOUS SITE, ADDITIONAL PC HOURS HAVE BEEN ADDED. ))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76407	11041-20002-01901	7217 N GEYSER AVE D/E/F	91335	3	183B121    48	2118025006	[Q]C2-1VL-CDO, [Q]P-1VL-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			07/27/2011 12:00:00 AM	07/28/2011 12:00:00 AM		Permit Finaled	09/29/2011 12:00:00 AM	ADDRESS	34.20173	-118.54275	Ti in an existing Appartment. EPC is for Commen area for T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76408	19041-10000-51000	2405 N CABOT ST	90031	13	144B213   143	5445002005	R1-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1972.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Finaled	02/07/2020 12:00:00 AM	ADDRESS	34.09359	-118.23911	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 17 MODULES (QCELL 305) , 17 OPTIMIZER (SE P320) AND A CENTRAL INVERTER (SE3800H-US).  SYSTEM SIZE IS 5.185KWdc and 3.8KWac	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76409	17041-10001-02377			14	129A211    59	5149024026	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			04/10/2018 12:00:00 AM			PC Approved	07/02/2018 12:00:00 AM	PIN	34.04826236	-118.24930401	(This is Plan check only, permit is covered under master # 17041-10000-02377) Supplemental plan check due to replacing material of few feeders to Aluminum. Voltage drop and Fault current calculation also updated.All changes are clouded and indicated as Delta-22, 25 <<<<PC FOR POWER AND ENERGY. EXTENDING  OFFICE  ON THE LEVEL 2 MEZZANINE, AND T.I FOR  OFFICE AND RETAIL IN A 13 STORY BUILDING.  SHELL ONLY.  NEW SERVICE 5000A 480/277 V. TOTAL AREA  38408 SQ FT.B# 16014-10000-04123>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76410	15041-20000-36444	10262 N NORRIS AVE	91331	7	204B165   110	2537003042	QMR1-1VL, [Q]M1-1	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			10/29/2015 12:00:00 AM			Corrections Issued	10/29/2015 12:00:00 AM	ADDRESS	34.25666	-118.4022	TI on (E) office build. installing new lighting fixtures. PC for Energy only, total area: 8,273sq.ft**NON-STRUCTURAL INTERIOR REMODEL ON THE FIRST FLOOR AND MEZZANINE FOR AN (E) WAREHOUSE/OFFICE - REMOVE (E) NON-BEARING WALLS AND RECONFIGURE FLOOR PLAN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76411	17041-20001-23935	21051 W SUPERIOR ST	91311	12	201B105   175	2746003003	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/17/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.24647	-118.59228	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted on commercial building.22.8kW ungrounded system. (66) 345W pv modules.Each module has a 400W power optimizer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76412	17041-10000-17289	5670 W WILSHIRE BLVD 23RD FLR-suite 2350	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM	06/28/2017 12:00:00 AM		Permit Finaled	09/16/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	TI TO OFFICE SPACE ON 23RD FLOOR. 5500 SQ FT. NEW LIGHTING. PC FOR T24 EENRGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76413	17041-10000-41878	808 S BROADWAY	90014	14	127-5A209 148	5144016066	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	09/29/2021 12:00:00 AM	ADDRESS	34.04342	-118.25478	PC FOR INSTALLATION OF NEW FIREALARM SYSTEM. CONSIST OF 1 FIREALARM PANEL AND 220 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76414	19041-10001-04679	15470 W VISTA HAVEN PL	91403	4	159B145    66	2279018015	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks	YES	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			02/08/2019 12:00:00 AM			PC Approved	02/28/2019 12:00:00 AM	ADDRESS	34.13595	-118.46939	EXPEDITE PER CUSTOMER REQUESTPV1. NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTMIZERS. (1) 11400H-US INVERTER AND (36) MODULES AND OPTIMIZERS (P400). SYSTEM SIZE IS 11.1KWAC AND 11.88KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76415	12041-20000-18568	15649 W ODYSSEY DR	91344	12	213B145   244	2605025***	[Q]OS-1XL, [T][Q]RD2-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1092.00	Electrical	Electrical	Apartment			08/08/2012 12:00:00 AM	08/08/2012 12:00:00 AM		Issued	08/08/2012 12:00:00 AM	ADDRESS	34.28372	-118.47101	outdoor lighting in gated community. Energy plan check private streets new plan check original plan check was expired	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76416	14041-20000-18228	18418 W COMMUNITY ST	91325	12	192B125   522	2786022040	RS-1	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2014 12:00:00 AM	07/08/2014 12:00:00 AM		Permit Finaled	09/24/2014 12:00:00 AM	ADDRESS	34.22246	-118.53455	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 3.8KW INTERCONNECTED WITH MAIN SERVICE PANEL.(1) SOLAR EDGE SE3800A(18) TRINA SOLAR TSM-255	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76417	14041-10000-06737	6240 E YORK BLVD	90042	14	153A231   440	5492034008	[Q]C4-1XL	East Los Angeles		Historic Highland Park		1831.01	Electrical	Electrical	Commercial			03/13/2014 12:00:00 AM	05/05/2014 12:00:00 AM		Permit Finaled	07/30/2014 12:00:00 AM	ADDRESS	34.11486	-118.18317	PLANCHECK FOR  POWER AND ENERGY. TENANT IMPROVEMENT FOR AN EXISTING RESTAURANT. 928 SQFT, EMERGENCY LIGHTING. NEWLY CONNECTED LOAD > 400AMPS.  FEES UNDER SUBMITTAL AND SUBMITTAL 2BUILDING P# 14016-10000-00390:  tenant   improvement  to  existing  restaurant     1152  sq  feet .  allow    outdoor   eating   area        two  tables    and   6 chairs  as  per  sheet I-1105.    Allow  drive  thru   restaurant  per  ZA 2013-795 CU.  Allow  hours  of  operation   of  0500- 0000 ( 12am).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76418	16041-20000-23189	4501 W GILBERT PL	90004	13	141B193  1057	5521008007	R3-1	Central	Wilshire	Wilshire Center - Koreatown		1925.20	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	09/20/2016 12:00:00 AM	ADDRESS	34.08074	-118.30243	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 4.5 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76419	17041-20000-28238	4533 N LAUREL CANYON BLVD	91607	2	165B165    30	2364005021	R4-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	Commercial			08/10/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Issued	08/10/2017 12:00:00 AM	ADDRESS	34.15303	-118.39667	Plan check for Title 24 only. Project site is (2) classrooms within an existing charter school. Project scope is a tenant improvement. Total lighting area = 2,405 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76420	10041-10002-10058	1902 W PARK AVE	90026	13, 14	139-5A207 209	5404002009	R3-1VL-CDO	Central, East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1957.20, 1975.00	Electrical	Electrical	Apartment			01/05/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.07616	-118.26168	UP TO DELTA 12 CHANGES TO APPROVED PLANS IN AN APARTMENT BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76421	15041-10000-22446	10960 W WILSHIRE BLVD 20TH FLOOR	90024	5	132B149   132	4324002028	[Q]C4-2-O	West Los Angeles	Westwood	Westwood		2655.10	Electrical	Electrical	Commercial			07/15/2015 12:00:00 AM			Corrections Issued	07/15/2015 12:00:00 AM	ADDRESS	34.058	-118.44597	TI-24 ON EXISTING COMMERCIAL BUILDING. NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT. PC FOR ENERGY ONLY. TOTAL SQ. FT = 6903	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76422	18041-20000-35244	20708 W WALNUT CIR	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/14/2018 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Finaled	05/09/2019 12:00:00 AM	ADDRESS	34.29453	-118.58494	Plan check for PV roof mounted system, system size: 8.04KW with 24 AC Moduels	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76423	16041-20001-32797	12751 W MILLENNIUM #115	90094	11	102B161  1227	4211033053	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			10/26/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	33.9761	-118.41651	10/26/2016 Changes to an approved set of plans. Changes have been made to the lighting floor plan and subpanels have been added in order to comply with power disaggregation requirements. All changes have been clouded and marked as Delta 3. All changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****Change of use from retail to dance studio.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76424	18041-10000-17868	617 W 7TH ST 202	90017	14	129A209    99	5144006024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	07/10/2018 12:00:00 AM	ADDRESS	34.04779	-118.2571	PC FOR OFFICE TI  IN A HIGH RISE BUILDING. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 4589 SQ.FT B# 18016-10000-11385	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76425	15041-20001-11927	5698 S GOLDENEYE CT UNIT 2	90094	11	102B161  1265	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			04/21/2015 12:00:00 AM			PC Approved	09/18/2015 12:00:00 AM	ADDRESS	33.9792	-118.41068	Expedite per applicant request******Plan check for PV1 roof monted system. System size: 3kWac with 8 modules(SUPOWER SPR-230NE-BLK-D) and 1 inverter(SB3000TL -US-22)PV CLEARANCE SHALL BE RELAVENT  TO UNIT # 1 OF ADDRESS 5698 GOLDENEYE CORT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76426	17041-10000-12428	6060 W CENTER DR #400	90045	11	102B169    70	4104001080	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			04/17/2017 12:00:00 AM	06/30/2017 12:00:00 AM		Permit Finaled	08/23/2017 12:00:00 AM	ADDRESS	33.97602	-118.39073	TI TO 3RD AND 4TH FLOORS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76427	15041-20000-12408	2525 W WASHINGTON BLVD	90018	10	126B189   855	5072030003	[Q]CM-1VL-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Commercial			04/24/2015 12:00:00 AM	09/25/2015 12:00:00 AM		Permit Finaled	04/15/2016 12:00:00 AM	ADDRESS	34.0401	-118.31864	Plan check power and energy for T.I. office ware house  space. Total area: 13,292 sq ft. Upgrade from 400A to 600A service with new switch gear rated for 600A and new 9 panel boards.service is 120/240 3-phase. high leg warningUnit # 101,102,103,104,105,106,107, and 201	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76428	15041-20000-14367	5430 S CRENSHAW BLVD UNIT B	90043	8	108B185   458	5006008008	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	05/15/2015 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	33.9922	-118.33046	PC FOR PV SYSTEM. 1.5KW AC USING SINGLE TRANSFORMERLESS INVERTER. THIS SYSTEM CONNECTS TO TENANT AT 5430B CRENSHAW. THIS IS PROJECT 1/5. ALL SYSTEMS CONNECT TO SINGLE 400A SINGLE PHASE SERVICE.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76429	18041-10000-40309	645 S LOS ANGELES ST	90014	14	127-5A211 129	5148021003	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			10/22/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.04374	-118.25017	PLANCHECK FOR POWER ONLY. NEW SERVICE UPGRADE TO 800 AMPS, with 4 panels and associated circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76430	18041-10000-47594	1660 W 185TH ST	90248	15	060B193    91	6108001036	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Issued	12/20/2018 12:00:00 AM	ADDRESS	33.86335	-118.30781	Plan check for PV1 3.8 kw AC / 2.6KW DC system with (10) module and (1) inverter interconing through  the main service panel.Portion of the permit fee is paid under 18041-90000-39650	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76431	19041-10001-05296	1958 N GRAMERCY PL	90068	4	150A193    23	5587021002	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			02/13/2019 12:00:00 AM			PC Approved	03/07/2019 12:00:00 AM	ADDRESS	34.10692	-118.31288	EXPEDITE FEE.<<<NEW ROOF MOUNTED 9.975KW PV SYSTEM WITH 420 PV TILES ON A SINGLE FAMILY HOME.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76432	17041-10002-23165	5654 W MANCHESTER AVE	90045	11	096B169   549	4125018014	M2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/18/2017 12:00:00 AM			Corrections Issued	08/18/2017 12:00:00 AM	ADDRESS	33.95967	-118.38015	PC FOR POWER FOR FIRST TIME TENANT IDENTIFIED ON SITE BY INSPECTION. ********************************************************************PC FOR RESTAURANT TI FOR TITLE -24, ENERGY ONLY. TOTAL AFFECTED AREA 834 SQ. FTTHIS IS PALN CHECK ONLY!!PERMIT PULLED UNDER MASTERB# 17016-10000-04151 OUTLETS, LIGHTS AND SWITCHES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76433	17041-30000-33832	415 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			09/21/2017 12:00:00 AM	09/21/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	33.77391	-118.27885	Plan check for Title 24 only in existing space office and wearhouse area T.I. Total area: 8,900 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76434	18041-10001-07393	23862 W DEL CERRO CIR	91304	12	186B089   257	2027033026	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.21	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2018 12:00:00 AM			PC Approved	04/17/2018 12:00:00 AM	ADDRESS	34.20784	-118.64589	Installation of roof-mounted solar PV system, not exceeding a total AC output of 8.7 kW, in a 1 or 2 family dwelling. System consist of 30 micro-inverters (IQ-6) with 30 modules. Permit fee is paid under original application number: 18041-90000-07393.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76435	18041-20000-46861	13266 W SEVILLANA WAY LOT 16	91342	7	225B157   282	2510012019	(T)(Q)RD1.5-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	08/14/2019 12:00:00 AM				Plan check for PV roof mounted system, system size: 1.68KW with 7 PV Modules and 7 microinverters. Standard Plan is being use.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76436	16041-10000-11721	5221 S WESTERN AVE #1 - #21	90062	8	108B193   369	5005030028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Apartment			04/26/2016 12:00:00 AM	07/27/2016 12:00:00 AM		Permit Finaled	08/25/2017 12:00:00 AM	ADDRESS	33.99445	-118.30923	New 21 unit apartment, with 4-typical units. 1200 Amp 120/240 3 phase service. PC for Power and Energy. Not in Methane zone.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76437	19041-20000-31407	17719 W CHATSWORTH ST	91344	12	207B129   379	2712029019	C1-1XL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			08/12/2019 12:00:00 AM	08/13/2019 12:00:00 AM		Permit Finaled	11/08/2019 12:00:00 AM	ADDRESS	34.2651	-118.52048	Plan  check for Title 24 only existing Tenant Improveemnt to retail space. Total area: 2471 sq ft. B#19016-10000-09368	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76438	13041-10000-25059	11341 W COHASSET ST	91352	2	186B173   466	2315016026	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1230.10	Electrical	Electrical	1 or 2 Family Dwelling			09/12/2013 12:00:00 AM	09/12/2013 12:00:00 AM		Permit Finaled	11/25/2013 12:00:00 AM	ADDRESS	34.20675	-118.37839	PV1 ROOF-MOUNTED SOLAR ARRAY, INTERCONNECT WITH MAIN PANEL IN 1-STORY HOUSE. SYSTEM SIZE 2.5 KW DC WITH POWER OPTIMIZERS, TRANSFORMERLESS SYSTEM. (10) MODULES:TRINA #TSM-250PC05/PA05.18(1) INVERTER: SOLAREDGE #SE3000A-USOPTIMIZERS: OP250-LV	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76439	18041-20000-21440	17044 W MIDWOOD DR	91344	12	216B133   454	2607001017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.42	Electrical	Electrical	1 or 2 Family Dwelling			06/08/2018 12:00:00 AM	06/21/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.28698	-118.50358	Plan check for PV battery back up system, system size7.6kWac with 14 modules, 1 inverter(7.6kW), 9.8kWh LG Chem.  connected to 200A Service.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76440	12041-20000-08973	2700 S FIGUEROA ST STE 103	90007	9	121-5A203  98	5123018033	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2246.00	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	05/07/2012 12:00:00 AM		Permit Finaled	08/06/2012 12:00:00 AM	ADDRESS	34.02708	-118.27647	TI for restaurant. First time tenant. Low-rise commercial building. Brooklyn Water Bagel. 2030 conditioned sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76441	11041-10000-02748	16210 W DEVONSHIRE ST	91344	12	204B137   349	2678001005	C2-1VL, P-1VL	North Valley	Granada Hills - Knollwood	North Hills West	YES	1098.00	Electrical	Electrical	Commercial			02/11/2011 12:00:00 AM			PC Info Complete	05/19/2011 12:00:00 AM	ADDRESS	34.25724	-118.48534	Ti in a Smart & Find store. EPC is for Power & Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76442	15041-20000-13746	10721 S HICKORY ST	90059	15	088-5A215  28	6068002026	R1-1	South Los Angeles	Southeast Los Angeles	Watts		2430.00	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2015 12:00:00 AM	05/06/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	33.93826	-118.23597	Installation of new roof mounted solar PV array.  Total system size = 3.44 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76443	07041-10001-26556	140 S GRAMERCY PL	90004		138B193  1233	5516022005	R3-1		Wilshire	Greater Wilshire			Electrical	Electrical	Apartment			01/29/2010 12:00:00 AM			PC Info Complete	01/29/2010 12:00:00 AM	ADDRESS	34.07192	-118.31231	P/C ONLY.1-29-10 - Supplemental is for the addition of new XFMR, separation of section from distribution, and consolidation into panel 'HP'.  P/C is for Power only :: New apartment complex - Permit is for new service, new switchgear, new panels, new circuits, new equipment, and new outdoor lighting.  P/C is for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76444	17041-10001-03508	10430 N SEPULVEDA BLVD	91345	7	207B145   770	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			08/28/2017 12:00:00 AM			PC Approved	08/28/2017 12:00:00 AM	ADDRESS	34.26014	-118.46701	Revision to approved set, replace a horn/strobe from 110cd to 15cd, changes noted as delta-1. This is plan check only, permit is covered under master# 17041-10000-03508	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76445	15041-20000-24129	6256 N TOPANGA CANYON BLVD Ste C1210	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/28/2015 12:00:00 AM	08/25/2015 12:00:00 AM		Permit Finaled	10/05/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	TI to retail space (clothing store). First time tenant. Plan check for power and energy. Total sqft. 1,380.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76446	11041-20000-17016	14506 W VENTURA BLVD	91403	5	166-5A151 143	2276001001	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.00, 1413.01	Electrical	Electrical	Commercial			08/11/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	10/27/2011 12:00:00 AM	ADDRESS	34.1508	-118.44904	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT EXISTING COFFEE SHOP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76447	13041-10000-03819	11755 W WILSHIRE BLVD	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			02/13/2013 12:00:00 AM			PC Approved	02/13/2013 12:00:00 AM	PIN	34.04869377	-118.46238681	TENANT IMPROVEMENT FOR AN EXISTING OFFICE BUILDINGL. PLAN CHECK FOR TITLE 24. HIGH RISE BUILDING. 5757 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76448	12041-20000-15005	6643 N VAN NUYS BLVD	91405	6	180B149   271	2236010032	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.02, 1281.00	Electrical	Electrical	Commercial			06/27/2012 12:00:00 AM	01/04/2013 12:00:00 AM		Permit Finaled	06/06/2013 12:00:00 AM	ADDRESS	34.19192	-118.44902	fire damaged building new service	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76449	19041-20000-16698	22135 W ROSCOE BLVD LOT #1	91304	12	192B101   522	2010023020	(T)(Q)C2-1, CR-1L	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			05/06/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Permit Finaled	04/26/2021 12:00:00 AM	ADDRESS	34.21979	-118.6095	Plan check for PV roof mounted system, System size: 2.1KW with  7 PV Modules and 7 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76450	13041-10001-15723	1875 S CENTURY PARK EAST #400	90067	5	132B161    19	4319002060	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/03/2013 12:00:00 AM			PC Approved	07/03/2013 12:00:00 AM	ADDRESS	34.06115	-118.41457	MODIFICATION TO APPROVED SET OF PLANS IN REFERENCE TO APPLICATION NUMBER 13041-10000-15723, ADDED TWO ADDITIONAL F2 FIXTURES. PLAN CHECK FOR EMERGENCY LIGHTING.****************************************************************************13041-10000-15723 DESCRIPTION: PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO EXISTING SUITE #400. PERMITS SHALL OBTAINED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76451	14041-20000-15630	240 N LARCHMONT BLVD	90004	4	138B189   501	5515025002	[Q]C2-1D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			06/11/2014 12:00:00 AM	07/01/2014 12:00:00 AM		Permit Finaled	09/12/2014 12:00:00 AM	ADDRESS	34.0758	-118.32344	Plan check for Energy only.New lighting and emergency lighting in single story restaurant. 855 sqft.Permit under separate application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76452	19041-20000-09800	11201 W BURBANK BLVD 1	91601	2	174B173   916	2337032021	C2-1	South Valley	North Hollywood - Valley Village	NoHo		1242.04	Electrical	Electrical	Commercial			03/19/2019 12:00:00 AM	03/19/2019 12:00:00 AM		Issued	03/19/2019 12:00:00 AM	ADDRESS	34.17234	-118.37494	Plan check for Title 24 energy only Tenant Improvement existing space. Total area: 1416 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76453	15041-20000-40184	11051 W VICTORY BLVD	91606	2	180B173   615	2336001020	(T)(Q)C1.5-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	Commercial			11/30/2015 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	05/11/2016 12:00:00 AM	ADDRESS	34.18686	-118.37207	Tenant improvement of select areas of Target store (interior affected area: 6626 sq ft) and outdoor lighting totaling 8389 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76454	16041-20001-40242	219 S LA FAYETTE PARK PL 1-33	90057	13	136-5A203 125	5155014014	R4-1	Central	Westlake	Rampart Village		2086.20	Electrical	Electrical	Apartment			11/14/2016 12:00:00 AM			PC Approved	03/21/2017 12:00:00 AM	ADDRESS	34.06886	-118.27977	EXPEDITE PER APPLICANT REQUEST.Plan check for installation of solar pv system, roof-mounted on apartment building. Interconnect with 400A House Service (derating main to 200A). 38.5kW (7.7*5) ungrounded system. (155) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76455	19041-10000-44803	23731 W HARTLAND ST	91307	12	183B093   615	2034031036	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2019 12:00:00 AM	11/14/2019 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	34.19443	-118.64364	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 5.36KVA PV1 SYSTEM CONSISTING OF 23 MODULES, 23 MICROINVERTERS(ENPHASE IQ7X), AND 1 ESS(TESLA POWERWALL) CONNECTED TO EXISTING 200A SERVICEMAIN BREAKER DERATING SHALL BE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76456	18041-20000-33656	17100 W RANCHO ST	91316	5	168B133   259	2289011008	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.01	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2018 12:00:00 AM			PC Approved	09/17/2018 12:00:00 AM	ADDRESS	34.15795	-118.50648	Plan check only for new 600A 240/120V 1ph-3w service and associated building distribution and loads for new single family dwelling.  Electrical permit fees paid under 17010-20000-00684.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76457	15041-10000-29611	390 S SEASIDE AVE	90731	15	021B209   245	7440022909		Harbor				9800.31	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	12/12/2016 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	PIN	33.72674075	-118.24974163	INSTALL NEW GENERATOR AND ATS TO AN EXISTING PUMPING PLANT.  PLAN CHECK FOR POWER ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76458	19041-10000-09181	1401 S GRAND AVE	90015	14	124-5A207  21	5134017029	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			03/14/2019 12:00:00 AM	05/06/2019 12:00:00 AM		Issued	05/06/2019 12:00:00 AM	ADDRESS	34.03721	-118.26568	Intial submittal did not charge several equipment, panelboard sections, and branch circuits. These uncharged equipments will be charged under submittal 2.POWER PLAN CHECK FOR TEMP POWER FOR A HOSPITAL. SCOPE INCLUDES NEW 800A TEMP SERVICE. CLOUDED AREA UNDER OSHPD PROJECT #160025-19-00	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76459	15041-10000-06845	3755 W SANTA ROSALIA DR	90008	8	114B185   328	5032002046	C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/09/2015 12:00:00 AM	09/30/2015 12:00:00 AM		Permit Finaled	09/07/2016 12:00:00 AM	ADDRESS	34.00948	-118.33894	New commercial building with occupying restaurant.  800 A - rated service at 120V/208Y.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76460	16041-20000-33576	3640 S ASHWOOD AVE	90066	11	111B149   460	4245012002	R1-1VLD	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM	09/21/2016 12:00:00 AM		Permit Finaled	11/16/2016 12:00:00 AM	ADDRESS	34.00172	-118.4473	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (19) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76461	19041-10000-10837	1515 W 190TH ST ste. 440	90248	15	060B193   377	7351001023	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	03/26/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	33.85852	-118.30531	PC FOR POWER AND LIGHTING, TI TOTAL SQUARE FOOTAGE 3866.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76462	14041-10000-24238	2725 N HYPERION AVE	90027	4	151-5A205 224	5433026037	C4-1D, P-1	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			09/04/2014 12:00:00 AM	02/29/2016 12:00:00 AM		Permit Finaled	10/20/2016 12:00:00 AM	ADDRESS	34.10747	-118.27223	PC FOR POWER AND ENERGY. TI for SUPERMARKET.  TOTAL AREA 19154 SQ FT. INSPECTOR TO VERIFY CUSTOM FIXTURES.PER 2013 ENERGY CODE.B# 14016-10000-17809.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76463	18041-20001-45018	6214 W LA MIRADA AVE	90038	13	144B189   258	5534002024	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM			PC Approved	02/12/2019 12:00:00 AM	ADDRESS	34.09334	-118.32501	Expedite per applicant request Plan check for a PV2 roof-mounted PV system. System size is 35 kWdc/34.2 kWac and consists of (3) inverters, (100) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76464	17041-20002-20780	13641 W SHERMAN WAY	91405	2	183B157    16	2328007002	C1-1VL, R3P-1	South Valley	Van Nuys - North Sherman Oaks			1271.03	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.20136	-118.4302	07-27-2018 Changes to an approved set of plan. Changes include update current limiter to 15 current limiters at 1A, removed outdoor motion sensor, update feeder size, Title 24 calculation, all changes has been clouded as delta 1.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76465	15041-10000-35235	2201 E SANTA ANA BLVD SOUTH	90059	15	088-5A217 636	6067027008		South Los Angeles				2430.00	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2015 12:00:00 AM	10/21/2015 12:00:00 AM		Permit Finaled	01/27/2016 12:00:00 AM	ADDRESS	33.93548	-118.2334	PV1, ROOF SOLAR MOUNTED SYSTEM TOTAL SIZE IS 1.7KW. (8) MICROINVERTER (8) MODULES. (8) SE-F265KZD-3Y(8) m215-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76466	16041-20000-12648	1188 1/2 S MULLEN AVE	90019	10	129B185   236	5083011015	R2-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/13/2016 12:00:00 AM	ADDRESS	34.05261	-118.3341	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter and (16) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76467	17041-20000-04367	8111 N FAIRCHILD AVE	91306	3	189B109   137	2108030004	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2017 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	03/16/2017 12:00:00 AM	ADDRESS	34.21752	-118.58784	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.6 KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76468	19041-10000-42776	1831 S LA CIENEGA BLVD UNIT B	90035	10	126B173   239	4303024003	C1.5-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	South Robertson		2696.01	Electrical	Electrical	Commercial			10/21/2019 12:00:00 AM	12/13/2019 12:00:00 AM		Permit Finaled	05/01/2020 12:00:00 AM	ADDRESS	34.04346	-118.37696	T-24 ENERGY ONLY PLAN CHECK FOR A TI. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. TOTAL NEW CONNECTED LOAD IS LESS THAT 400A. TOTAL AFFECTED AREA IS 1059SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76469	18041-20002-28072	13646 W OSBORNE ST	91331	6	198B157   555	2625026003	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2018 12:00:00 AM			PC Approved	08/09/2018 12:00:00 AM	ADDRESS	34.23862	-118.43052	EXPEDITEpv1install roof mounted pv system sized 9.6KW AC interconnected with msp.(42) canadian soalr modules 295(42) IQ-6-60 microinverters	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76470	19041-10000-22506	550 S HOPE ST # 480	90071	14	130-5A209 209	5151026024	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/12/2019 12:00:00 AM	08/01/2019 12:00:00 AM		Permit Finaled	12/04/2019 12:00:00 AM	ADDRESS	34.04989	-118.25574	TENANT IMPROVEMENT IN OFFICES AND MEETING ROOMPLAN CHECK IS FOR TITLE 24	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
76471	17041-10000-10861	12727 W SHERMAN WAY Bldg. A08	91605	2	183B161    11	2324004004	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood West		1233.03	Electrical	Electrical	Commercial			04/04/2017 12:00:00 AM	05/19/2017 12:00:00 AM		Permit Finaled	03/13/2023 12:00:00 AM	ADDRESS	34.20137	-118.41091	Plan check for power and Title 24.  Change of use from retail to buffet restaraunt.  New subpanels and lighting.  Load exceeds 400 amps.  Tota area = 11,885 sq. ft.Building permit #14016-10000-16845	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76472	12041-20000-05970	22332 W LULL ST	91303	3	186B101   134	2012020046	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1343.04	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	PIN	34.20856185	-118.61358793	micro inverter 7.5KW PV system	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76473	15041-10000-08056	19500 W PLUMMER ST	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/19/2015 12:00:00 AM			PC Info Complete	03/19/2015 12:00:00 AM	ADDRESS	34.2426	-118.55846	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING, INSTALLING NEW LIGHTING NEW CONTTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1131	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76474	09041-10001-24370	7401 W WORLD WAY WEST	90045	11	090B157    94	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM			PC Approved	08/25/2010 12:00:00 AM	PIN	33.94363002	-118.42513364	Supplement to the approved plans Delta 4 (09041-10000-24370).  Remove a light pole and install 2 Pull Boxes and underground conduit  for the outdoor parking lot lighting for the FedEx building. LAWA - New composite shop facility at the FedEx hanger at LAX.   Permit is for new high voltage 4160 section to 480/277 distribution, panels, ckts, equipment, etc.  P/C is for Power and Energy.Site is in the Methane Zone	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76475	18041-10001-03192	5820 W LA MIRADA AVE	90038	13	144B189   223	5534019021	R3-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Apartment			02/01/2019 12:00:00 AM			Verifications in Progress	05/21/2019 12:00:00 AM	ADDRESS	34.09365	-118.31653	(( Original plan checker: Dian)) Resubmittal for plan check only, due to design and architectural change that impacted more than 50% of the original design. Building resubmittal plan check# 16010-20001-04089 due to design and architect change.Electrical Permit shall be issued under the master plan check number.<<FULL PC FOR POWER AND ENERGY FOR A (N) 4-STORY (18) UNIT APT BLDG W/ BASEMENT SUBTERRANIAN PARKING GARAGE. SCOPE INCLUDES ADDING A NEW 1200A SERVICE. TOTAL AFFECTED AREA IS 18847 SQ. FT.((B# 16010-20000-04089))>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76476	10041-10000-13048	6801 W HOLLYWOOD BLVD SUITE 147-# C1-137	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			07/08/2010 12:00:00 AM	07/21/2010 12:00:00 AM		Permit Finaled	09/16/2014 12:00:00 AM	ADDRESS	34.10229	-118.33907	TENANT IMPROVEMENTS AT A GAP STOREPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76477	18041-10000-15949	2415 E 15TH ST	90021	14	120A217   267	5168010011	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	06/06/2018 12:00:00 AM	ADDRESS	34.02106	-118.22952	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76478	18041-20000-47154	20332 W VIA GALILEO	91326	12	219B113   167	2701044019	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Issued	12/12/2018 12:00:00 AM	ADDRESS	34.29529	-118.57661	Plan check for a PV1 roof-mounted PV system. System size is 15.275 kWdc/13.97 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (47) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76479	15041-10000-14856	1429 N TAMARIND AVE	90028	13	147A191   129	5545014013	[Q]R4-2	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			05/19/2015 12:00:00 AM	01/25/2016 12:00:00 AM		Permit Finaled	07/29/2016 12:00:00 AM	ADDRESS	34.09648	-118.3192	CHANGE OF USE FROM RESIDENTIAL TO COMMERCEIAL CHILD CARE CENTER, UNDER BUILDING NUMBER 15016 10000 04491.  TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1645.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76480	18041-10000-38326	5849 S CROCKER ST	90003	9	108B205  1217	6006029001	[Q]MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	33.98846	-118.26863	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76481	13041-10000-01477	712 S SANTA FE AVE	90021	14	124-5A217 311	5166002019	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			01/18/2013 12:00:00 AM	07/23/2013 12:00:00 AM		Permit Finaled	03/17/2014 12:00:00 AM	ADDRESS	34.03393	-118.22985	First time tenant for a restaurant space.  Power and energy.PLACE OF ASSEMBLY. OCCUPANT LOAD: 220+	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76482	10041-10000-17465	9185 N DE SOTO AVE	91311	12	198B109   127	2746009022	(Q)C2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			09/03/2010 12:00:00 AM	09/03/2010 12:00:00 AM		Permit Finaled	10/22/2010 12:00:00 AM	ADDRESS	34.23801	-118.5888	install a new fire alarm system in the building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76483	15041-10002-30289	3782 W MARTIN LUTHER KING, JR BLVD	90008	10	117B181  1083	5032005006	[Q]C2-2D	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2361.00	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM			PC Approved	03/28/2017 12:00:00 AM	ADDRESS	34.01318	-118.34004	3/28/17: Changes to approved set. Revise AIC rating due to feeder changes. Also refelcting portions of project approved under separate permits. all changes noted delta G on plans. pc only. no further permit to be issued	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76484	19041-10000-07155	6502 N VINELAND AVE	91606	2	180B173   673	2414028026	RD2-1	South Valley	North Hollywood - Valley Village	NoHo		1231.03	Electrical	Electrical	Commercial			02/27/2019 12:00:00 AM	02/28/2019 12:00:00 AM		Permit Finaled	05/31/2019 12:00:00 AM	ADDRESS	34.18875	-118.37009	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES (OUTDOOR) - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76485	17041-10000-23842	10548 N LUBAO AVE	91311	12	207B113   320	2708019036	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2017 12:00:00 AM	07/14/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.26101	-118.56729	Plan check for roof mounted PV system - System consist of 32 microinverter (M250), with 32 panels (rec solar 280TP). system size = 8.0KVA	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76486	13041-20001-25774	7255 N WINNETKA AVE	91306	3	186B113   754	2114018014	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.20	Electrical	Electrical	Apartment			09/18/2013 12:00:00 AM			PC Approved	10/08/2013 12:00:00 AM	ADDRESS	34.20295	-118.57119	Expedite Fees only.     <<New 20.28kw rooftop mounted PV system on an existing 2-story apartment building.   Service upgrade from 100amps to 175 amps is on a separate application.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76487	17041-20002-34489	15926 W HAMLIN ST	91406	6	180B141   834	2233014016	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.06	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2017 12:00:00 AM			PC Approved	11/28/2017 12:00:00 AM	ADDRESS	34.1876	-118.48031	[[[[11/28/17 CHANGES TO APPROVED SET. PLANCHECK ONLY. REMOVING A DISCONNECT AND MOVING THE LOCATION OF SOLAR EQUIPMENTS. CHANGES ARE CLOUDED]]]]Plan check for solar pv system (roof-mounted array) and AC coupled battery backup system for SFD.5kW ungrounded pv system. (16) 325W pv modules. (1) 5kW Tesla Powerwall 2.Each module has a 400W power optimizer.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76488	19041-10000-45411	29050 S WESTERN AVE 101A	90275	15	021B193    39	7445004242	(Q)C2-1VLD	Harbor	San Pedro	Northwest San Pedro	YES	2963.00	Electrical	Electrical	Commercial			11/05/2019 12:00:00 AM			PC Info Complete	12/02/2019 12:00:00 AM	PIN	33.75477294	-118.30875089	PLAN CHECK FOR TITLE 24 ONLY. TOTAL AFFECTIVE AREA 1250 SQ/FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76489	17041-10000-24906	3518 N SIERRA ST	90031	1	142-5A227 104	5304035027	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1992.02	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2017 12:00:00 AM	07/31/2017 12:00:00 AM		Permit Finaled	09/27/2017 12:00:00 AM	ADDRESS	34.08589	-118.19974	PC FOR PV SYSTEM SFD, TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM AND 18 MODULES WITH POWER OPTIMIZERS.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76490	15041-20001-41746	338 S HIGHLAND AVE	90020	4	135B185   183	5507003007	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/23/2015 12:00:00 AM			PC Approved	12/23/2015 12:00:00 AM	PIN	34.06772806	-118.33811993	Original PC utilized standard plan, additional PC needed because of the MS is 400A. No additional fee per CA State Bill 1222.Permit under 15041-20000-41746*******PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF TOP. TOTAL SYSTEM SIZE IS 6.75KWac/7.695KWdc.(27)MODULES-SOLAR WORLD SW285 MONO(27)MICROINVERTERS-ENPHASE M250-60-2LL-S22-IG(1) 100A SUBPANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76491	18041-10000-31409	230 S GAFFEY ST	90731	15	018B197  1468	7451016013	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			08/17/2018 12:00:00 AM	11/30/2018 12:00:00 AM		Permit Finaled	02/28/2019 12:00:00 AM	ADDRESS	33.74186	-118.29212	Install Rofftop solar system (PV2) on (E) commercial building. System size: 12 kW DC / 10.75 kW AC. (50) modules with Enphase IQ6, and (1) 100 A combiner box.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76492	14041-10000-12645	6555 W BARTON AVE WEST BLDG	90038	4	144B185  1067	5532014032	(T)(Q)M1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			05/12/2014 12:00:00 AM	08/28/2014 12:00:00 AM		Permit Finaled	06/30/2015 12:00:00 AM	ADDRESS	34.08785	-118.33475	NEW FIRE ALARM SYSTEM FOR COMMERCIAL BUILDING. 183 DEVICES AND 1 PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76493	09041-10002-21461	6801 W HOLLYWOOD BLVD	90028	13	148-5A185 402	5548004***	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1901.00	Electrical	Electrical	Commercial			11/03/2010 12:00:00 AM			PC Approved	11/03/2010 12:00:00 AM	ADDRESS	34.10229	-118.33907		N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76494	19041-20000-30852	20332 W RUNNYMEDE ST	91306	3	186B113   457	2114010017	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2019 12:00:00 AM	08/14/2019 12:00:00 AM		Permit Finaled	09/05/2019 12:00:00 AM	ADDRESS	34.20575	-118.57653	Plan check for PV roof mounted system, PV system size: 5.9KW DC, 5.0KW AC with 19 PV Modules and 1 inverter(5.0KW).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76495	18041-10000-21664	20333 S NORMANDIE AVE	90501	15	054B193    79	7351020021	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/15/2018 12:00:00 AM	12/07/2018 12:00:00 AM		Permit Finaled	05/17/2021 12:00:00 AM	ADDRESS	33.84604	-118.29972	PC FOR ROOF MOUNTED FEED AND TARIFF PV SYSTEM. SYSTEM SIZE 3.297 MWDC / 2.564 MWACSCOPE INCLUDES 8244 MODULES WITH OPTIMIZIERS  , 77 3PH 277/480 33.3KW INVERTERS,  19 SUB-PANELS 4000A 277/480 SWITCH GEAR AND 34.5KV/480V TRANSFORMEER WITH  34.5KV DISCONNECT. PERMIT FEE IS $ 0 IN ACCORDANCE WITH AB 1414	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76496	18041-10000-07688	7540 WORLD WAY WEST	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	07/16/2018 12:00:00 AM		Permit Finaled	03/10/2020 12:00:00 AM	ADDRESS	33.94052	-118.42863	PC for power, Delta high bay hangar with one story of office space. New 3000A service, panels and circuits.    Title 24 under a separate permit, Mehdi Zandi	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76497	15041-10001-25608	621 W 54TH ST	90037	9	108B201   539	5001026013	R2-1	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	1 or 2 Family Dwelling			08/07/2015 12:00:00 AM			PC Approved	08/18/2015 12:00:00 AM	ADDRESS	33.99338	-118.28497	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 3.92 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME.(12) MODULES: SUNPOWER SPR327NE(1) INVERTER: POWERONE PVI-3.0-OUTD-US-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76498	14041-10000-16313	19800 W VENTURA BLVD	91364	3	174B117   369	2164011027	(T)(Q)C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			06/18/2014 12:00:00 AM	12/17/2014 12:00:00 AM		Permit Finaled	09/26/2017 12:00:00 AM	ADDRESS	34.17216	-118.56413	PLAN CHECK FOR POWER AND LIGHTING - TOTAL AREA = 15,140 SQ FTNEW TENNANT IMPROVEMENT - NEW LIGHTS AND POWER DISTRIBUTION THROUGHOUT, REPLACE EXISTING BACK UP GENERATOR.  EXISTING COMMERCIAL LOW-RISE SPACE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76499	16041-10000-11232	1960 W SUNNY HEIGHTS DR	90065	1	150A219   172	5464031001	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.04	Electrical	Electrical	1 or 2 Family Dwelling			03/31/2016 12:00:00 AM	03/31/2016 12:00:00 AM		Permit Expired	05/02/2018 12:00:00 AM	ADDRESS	34.10556	-118.22482	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.655KWac.(17)MODULES-TRINA TSM-265 PD05.08 265 WATT(17)MICROINVERTERS-M215-60-2LL-S2X-IG	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76500	13041-20003-26892			11	132B145   503	4401018019	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			12/10/2014 12:00:00 AM			PC Approved	12/30/2014 12:00:00 AM	PIN	34.05417634	-118.46403685	12/10/2014 - Changes to approved set to reflect as built plans.  Addition of new manufacturer supplied panel 'RCP' with loads reclocated from panel 'D'.  Changes to lighting including revisions to title 24 plans.  All changes have been clouded. DELTA 3 REVISIONS. *****Previous work description******PC FOR POWER AND ENERGY. RESTAURANT REMODEL. GREATER THEN 400A LOAD. (plan check for addition of patio heaters. all changes clouded. )))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76501	10041-20000-07728	5701 N PLATT AVE	91367	3	174B093   222	2045024003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.02	Electrical	Electrical	Commercial			04/27/2010 12:00:00 AM			PC Approved	04/27/2010 12:00:00 AM	ADDRESS	34.17396	-118.64329	Revision to previously approved plan of 07041-20000-26762. Changing 3 UPS in to one  3kw to serve to light emergecy fixtures in a mosque.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76502	13041-10000-24754	729 W 28TH ST	90007	9	121-5A203  48	5123016402	RD1.5-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Apartment			09/10/2013 12:00:00 AM	09/17/2013 12:00:00 AM		Permit Finaled	05/20/2014 12:00:00 AM	ADDRESS	34.02755	-118.28038	INSTALLING NEW FIRE ALARM SYSTEM IN 2-STORY APARTMENT( + ROOF). FULLY-SPRINKLER SYSTEM. 23256 SQ FT. 67 DEVICES, 1 PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76503	11041-10001-20669	1410-1418 S ELKGROVE CIR BLDG 15	90291	11	111B149   425	4243001034	[Q]RD1.5-1XL	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Apartment			04/16/2014 12:00:00 AM	04/21/2014 12:00:00 AM		Permit Finaled	07/09/2014 12:00:00 AM	ADDRESS	34.00138	-118.45818	LINCOLN PLACE APARTMENT PROJECT> Addition of 3 EV chargers.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76504	16041-10000-16550	17383 W SUNSET BLVD	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			05/12/2016 12:00:00 AM	11/04/2016 12:00:00 AM		Permit Finaled	04/10/2017 12:00:00 AM	ADDRESS	34.03917	-118.55529	Energy plan check for an existing parking building T.I. Total area is 160,027 SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76505	13041-10001-20913	22843 W SHERMAN WAY	91307	12	183B097    69	2021017003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2013 12:00:00 AM			Reviewed by Supervisor	08/20/2013 12:00:00 AM	ADDRESS	34.20115	-118.62499	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76506	17041-20000-12024	21650 W OXNARD ST 2nd flr-corridor	91367	3	177B105    83	2146006042	DT(WC)-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	34.17901	-118.60107	ti to an existing commercial building (high rise).  adding new lighting new controls to existing panels. plan check for energy only.  total square footage 1553.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76507	15041-20000-05689	14933 W CALVERT ST	91411	6	178-5A149 315	2242024050	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			PC Info Complete	09/30/2015 12:00:00 AM	ADDRESS	34.18132	-118.4586	Plan check for power only. 2500 A service upgrade to existing commercial building.  New switchgear and subpanels.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76508	11041-20000-11373	1411 W 190TH ST 225	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			06/02/2011 12:00:00 AM			PC Approved	06/02/2011 12:00:00 AM	ADDRESS	33.85852	-118.30317	T.I. to existing high rise building.  Install general/emergency lighting.  Plan check for energy only.Note: Permit under 11041-90000-09544	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76509	16041-10001-06771	349 W 45TH ST	90037	9	112-5A203 114	5110003013	RD2-1	South Los Angeles	Southeast Los Angeles			2319.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	34.00298	-118.28	Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76510	12041-10001-21529	7221 N VAN NUYS BLVD	91405	6	183B149    24	2218024015	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			12/17/2012 12:00:00 AM			PC Approved	12/20/2012 12:00:00 AM	ADDRESS	34.20192	-118.44901	"CHANGES TO APPROVED SET OF PLANS. PLAN CHECK ONLY. CHANGES TO LIGHTING PLAN AND EMERGENCY LIGHTS.************************************** 12041-10000-21529TENANT IMPROVEMENT FOR ""THE HABIT BURGER"" RESTAURANT IN AN EXISTING RETAIL SPACE (FORMERLY HOLLYWOOD VIDEO).  CHANGE OF USE FROM RETAIL TO RESTAURANT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76511	11041-20001-07523	5911 W HOLLYWOOD BLVD	90028	13	148-5A191 145	5545003016	C4-1-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			08/04/2011 12:00:00 AM			PC Approved	08/04/2011 12:00:00 AM	ADDRESS	34.10183	-118.31846	Revision to approved plans. Changes to T24 lighting calculcation and fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76512	18041-20000-37767	1664 S HI POINT ST	90035	10	129B173  1432	5068019034	R1R3-RG-O	Central	Wilshire	P.I.C.O.		2167.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2018 12:00:00 AM	10/03/2018 12:00:00 AM		Permit Finaled	01/07/2019 12:00:00 AM	ADDRESS	34.04625	-118.37005	PV1install roof mounted pv system sized 10KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76513	18041-20001-39864	4048 N BALLINA DR	91436	5	165B137   586	2286007017	RE15-1-H	South Valley	Encino - Tarzana	Encino	Yes	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2018 12:00:00 AM			PC Approved	10/19/2018 12:00:00 AM	ADDRESS	34.14446	-118.49038	10-19-2018 Changes to an approved set of plan, changes include change pv racking system to IRONRIDGE. Changes has been clouded.Plan check only Fees $0 due California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76514	19041-10000-30857	10848 W CANTARA ST	91352	2	192B173   787	2407025010	[Q]M1-1-CDO, [Q]MR1-1-CDO	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1222.00	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Issued	08/08/2019 12:00:00 AM	ADDRESS	34.21921	-118.36637	Remove HID fixtures and replace with new LED fixtures (Outdoor Only)- T24 Only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76515	12041-10000-18040	1160 W HARRY BRIDGES BLVD DRIVER-SERVICES	90744	15	027B201   208	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Finaled	12/19/2014 12:00:00 AM	PIN	33.77018478	-118.27675111	NEW 1-STORY DRIVER SERVICE BUILDING FOR THE PORT OF LA. EPC IS FOR POWER & ENERGY. FIRE ALARM PLAN WAS SUBMITTED SEPARATELY. (PART OF TRAPAC TERMINAL PROJECT)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76516	19041-20001-02748	3827 S MUIRFIELD ROAD	90008	10	117B181   405	5045002011	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2362.03	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2019 12:00:00 AM			PC Approved	01/29/2019 12:00:00 AM	ADDRESS	34.0166	-118.34278	Expedite per appliant request Plan check for PV roof mounted system with Energy Storage System, system size: 4.8KW with 15 PV Modules and 1 inverter(7.6KW), LG Chem 9.8kWh.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76517	16041-10000-05958	426 E 82ND ST	90003	9	099B205  1289	6030030017	R2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2398.02	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM	02/19/2016 12:00:00 AM		Permit Expired	03/21/2018 12:00:00 AM	ADDRESS	33.96451	-118.26627	PV1 roof mounted solar system installation to a single family home. Inverter rating is 3.0 kw, (8) Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76518	19041-10000-14926	8131 N TAMPA AVE	91335	3	189B117    40	2105020004	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	Commercial			04/23/2019 12:00:00 AM	04/23/2019 12:00:00 AM		Permit Finaled	05/28/2019 12:00:00 AM	ADDRESS	34.21836	-118.55375	Replacing Existing Fluorescent troffers with LED retrofit kits. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76519	10041-20001-10517	700 W WORLD WAY Terminal 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/29/2011 12:00:00 AM	04/12/2011 12:00:00 AM		Permit Finaled	06/03/2011 12:00:00 AM	PIN	33.94153561	-118.3984113	"Changes from previously approved plans.  Changes include adding ""power servers"" to existing panel ""G-74A"" and ""PD"" as shown on plans.  *****PLAN CHECK TO INSTALL NEW VEHICLE BATTERY CHARGING STATIONS FOR UNITED AIRLINES TERMINAL 7& 8, HANGAR 1, HANGAR 2, AND CARGO BLDG AT LAX.*****"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76520	17041-10000-06479	11400 N FENTON AVE	91342	7	213B169   880	2530033012	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.24	Electrical	Electrical	1 or 2 Family Dwelling			02/28/2017 12:00:00 AM	02/28/2017 12:00:00 AM		Permit Finaled	05/18/2017 12:00:00 AM	ADDRESS	34.27697	-118.3859	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(21)MODULES-HANWHA Q-CELL Q PLUS(21)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE5000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76521	17041-20000-13349	10271 W KILRENNEY AVE	90064	5	126B161   645	4316002014	R1-1	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	05/26/2017 12:00:00 AM	ADDRESS	34.03751	-118.4071	pv1install roof mounted pv system sized 3kw interconnected with msp.  standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76522	15041-10000-16335	4232 E GLENWOOD AVE	90065	1	147A223   200	5465017024	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	07/01/2015 12:00:00 AM	ADDRESS	34.09697	-118.21251	PV1.  Installation of utility-interactive, rooftop-mounted 6 kW PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76523	12041-20000-23852	11835 W OLYMPIC BLVD	90025	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			10/05/2012 12:00:00 AM	10/05/2012 12:00:00 AM		Permit Finaled	11/20/2012 12:00:00 AM	PIN	34.03318579	-118.45141815	TITLE 24 PLAN CHECK. EXISTING OFFICE T.I. REMODEL. NO NEW CIRCUITS. NO EMERGENCY LIGHTING. 2454 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76524	14041-10000-07192	960 N MAIN ST	90012	14	135A217   177	5409009006	M3-1	Central	Central City North			2060.00	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Expired	04/11/2016 12:00:00 AM	PIN	34.06202155	-118.23379153	T24, REMOVE EXISTING HID LIGHT FIXTURES WITH NEW FLORESCENT LIGT FIXTURES. TOTAL AREA 12296 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76525	15041-20000-12120	21600 W OXNARD ST 19TH FLOOR	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM			PC Approved	04/22/2015 12:00:00 AM	ADDRESS	34.179	-118.6002	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. NEWLY CONNECTED LOAD < 400 AMPS. 19TH FLOOR. 2784 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76526	19041-10000-39268	1100 S GLENDON AVE	90024	5	132B153   143	4363021018	C4-2D-O	West Los Angeles	Westwood	North Westwood		2652.02	Electrical	Electrical	Commercial			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Issued	09/30/2019 12:00:00 AM	ADDRESS	34.06074	-118.44418	PLAN CHECK FOR TITLE 24 ONLY FOR REPLACEMENT OF EXISTING FIXTURES - TOTAL AFFECTED AREA = 7919 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76527	14041-20001-23042	3783 S WADE ST	90066	11	111B153   436	4246032041	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2014 12:00:00 AM			PC Approved	10/03/2014 12:00:00 AM	ADDRESS	34.00201	-118.43856	Modification to approved set.  Relocation of MSP to match existing field conditions.  $0 submittal fee is due to Senate Bill SB-1222. (((PV1 SFD. TOTAL SYSTEM SIZE 5KW AC USING TRANSFORMERLESS INVERTERS. USING STANDARD PLAN. TOTAL OF 20 MODULES)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76528	12041-10000-31133	7737 S TOLAND AVE	90045	14	099B173   396	4127017015	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1863.00	Electrical	Electrical	1 or 2 Family Dwelling			12/28/2012 12:00:00 AM	12/28/2012 12:00:00 AM		Permit Finaled	01/17/2013 12:00:00 AM	ADDRESS	33.96712	-118.3761	PV1 2 STORY HOUSE 14 MODULES [MODULES: REC {REC 245 PE}] [MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76529	18041-30001-19964	601 S FIGUEROA ST 3rd Floor	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/11/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Changes to approved set of plan noted as Delta-2 and Delta-D, scope includes removal of some lighting in studio room, and revision to T24 calculation accordingly. *This is plan check only, permit is covered under  master: 18041-20000-19964<<Plan check for Title 24 only in existing high-rise building T.I. Total area: 7940 sq ft.>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76530	15041-20000-30800	17330 W MIDWOOD DR	91344	12	216B133   542	2606015019	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			09/17/2015 12:00:00 AM			Reviewed by Supervisor	10/02/2015 12:00:00 AM	ADDRESS	34.28583	-118.51165	PV1 ROOF MOUNTED SYSTEM, INTERCONNECT WITH 400A MSP. (38) MODULES AND (2) INVERTER. TOTAL SIZE 8.4.(38) KYOCERA #KU2656ZPA(2) ABB#PV1-4.2-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76531	11041-20000-06632	7134 N SEPULVEDA BLVD	91405	6	183B145    83	2220022***	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1278.01	Electrical	Electrical	Commercial			04/04/2011 12:00:00 AM	05/23/2011 12:00:00 AM		Permit Finaled	08/19/2011 12:00:00 AM	ADDRESS	34.20015	-118.46599	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR KITCHEN REMODEL.  LIGHTING ON EXISTING CKTS AND TIME CLOCK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76532	18041-10000-04820	10220 W CONSTELLATION BLVD	90067	5	132B161   724		C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			02/08/2018 12:00:00 AM	06/07/2018 12:00:00 AM		Permit Finaled	09/19/2022 12:00:00 AM	ADDRESS	34.05798	-118.41653	PC for FA system in retail podium century plaza. Installing 153 devices, 1 FACP, 5 RPS and an annunciator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76533	19041-10000-05248	2714 N ST GEORGE ST	90027	4	150B201   490	5433024004	R2-1XL	Central	Hollywood	Los Feliz		1952.01	Electrical	Electrical	Commercial			02/13/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.10838	-118.2753	NEW FIRE ALARM SYSTEM IN A SCHOOLS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76534	18041-10000-19627	355 S GRAND AVE 6TH FLR	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	06/28/2018 12:00:00 AM		Permit Finaled	08/29/2018 12:00:00 AM	ADDRESS	34.05191	-118.2525	Energy plan check for an office T.I located on the 6th floor of a commerical building. Scope includes new lighting and equipment. Total area is 5810-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76535	16041-20000-10146	422 S LAKE ST	90057	1	135A203   398	5154030019	(T)R4P-2	Central	Westlake			2088.01	Electrical	Electrical	Apartment			03/23/2016 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	02/01/2018 12:00:00 AM	ADDRESS	34.06229	-118.27435	PLANCHECK FOR POWER AND ENERGY. New 5-story (Type IIIA), 80 unit apartment over 2 levels of subterrean parking garage (Type IA). FIRE ALARM VARIANCE HAS BEEN SUBMITTED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76536	12041-20000-11713	5670 W WILSHIRE BLVD	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.00, 2163.00	Electrical	Electrical	Commercial			05/22/2012 12:00:00 AM	05/22/2012 12:00:00 AM		Permit Finaled	06/27/2012 12:00:00 AM	ADDRESS	34.06222	-118.35208	T24 lighting plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76537	17041-20001-16762	20751 W MARILLA ST	91311	12	201B109   151	2748004043	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM			PC Approved	09/07/2017 12:00:00 AM	ADDRESS	34.24825	-118.58596	9/7/2017CHANGES TO AN APPROVED SET OF PLANS.  CHANGES INCLUDE VOLTAGE CLASS FROM 120/208 TO 480/277.  NO NEW EQUIPMENT.  THIS IS PLAN CHECK ONLY.(((PC FOR POWER. SERVICE UPGRADE TO 2000AMP 120/208V 3 PHASE, 4 WIRE, ADDITION OF 2 NEW 200AMP PANELS AND 4 TRANSFORMERS. (E)COMMERCIAL BUILDING)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76538	16041-10002-42255	700 W WILSHIRE BLVD Suite B	90017	14	129A209    65	5144006020	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	08/23/2017 12:00:00 AM		Issued	08/23/2017 12:00:00 AM	ADDRESS	34.04863	-118.25733	08/23/2017Changes to an approved set of plans, changes include the addition of a panel. Note change on delta 9 and 3.plan check for energy only.  __________________Note: Building application has been generated under 16016-30000-28764	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76539	19041-20001-05953	5247 N BUFFALO AVE	91401	4	171B157   423	2344016019	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/01/2019 12:00:00 AM	ADDRESS	34.1662	-118.43025	Revisions to online permit approved plans - plan check of contractor design set due to errors in online permit plan printout. NO FEE DEPARTMENTAL ERROR.(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76540	19041-20000-18119	20843 W PINECONE CIR 24	91326	12	219B109   359	2701098004	[T]RE-1, [T]RE20-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.29592	-118.58837	PV1.  Install 4.02 kW roof mounted grid tied PV system.  (12) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76541	18041-10000-42886	608 S HILL ST	90014	14	129A211   151	5144003015	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM			Reviewed by Supervisor	11/15/2018 12:00:00 AM	ADDRESS	34.04696	-118.25321	INSTALLATION OF FA FOR WESTERN JEWELRY MART. 1 FACP AND 174 DEVICES	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76542	19041-20000-52141	12527 W HESBY ST	91607	2	171B161   930	2357008029	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.16201	-118.40613	PV1 PLANCHECK FOR NEW ROOF PV. SYSTEM SIZE IS 14.85 KW DC/11.4 KW AC. SCOPE OF WORK CONSISTS OF (45) PV MODULES WITH OPTIMIZERS, AND A 11.4 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76543	17041-10000-18199	11111 W SANTA MONICA BLVD 11TH FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			06/01/2017 12:00:00 AM	06/29/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC FOR TITLE 24 ENERGY ONLY. INTERIOR RENOVATION OF EXISTING RATED CORRIDOR + RESTROOMS ON 11TH FLOOR.TOTAL AFFECTED AREA 944 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76544	17041-10000-33525	500 S LOS ANGELES ST	90013	14	129A211   247	5148018026	[Q]R5-2D	Central	Central City	Downtown Los Angeles		2063.00	Electrical	Electrical	Commercial			09/19/2017 12:00:00 AM	09/19/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.04579	-118.24757	Remove HID fixture and replace with new LED fixtures - T/24 only.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76545	15041-20000-20378	955 E 31ST ST	90011	9	117A209   115	5114022012	M1-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			06/29/2015 12:00:00 AM	07/17/2015 12:00:00 AM		Permit Finaled	08/31/2015 12:00:00 AM	ADDRESS	34.01537	-118.25814	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,410 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76546	10041-20000-19466	6900 S VERMONT AVE	90044	8	102B197   669	6013005806	C2-1VL	South Los Angeles	South Los Angeles			2375.00	Electrical	Electrical	Commercial			09/30/2010 12:00:00 AM	11/12/2010 12:00:00 AM		Permit Finaled	02/25/2011 12:00:00 AM	ADDRESS	33.97704	-118.29132	Plan check for intallation of 600A boards and rectifier equipment for AT&T Power Plant.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76547	19041-10000-38590	2425 E PORTER ST	90021	14	121-5A217 242	5168030012	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/01/2020 12:00:00 AM	ADDRESS	34.02674	-118.22899	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76548	18041-10000-46408	7831 S SEPULVEDA BLVD	90045	11	099B165   141	4109002033	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	Commercial			12/06/2018 12:00:00 AM	12/06/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.97046	-118.39548	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76549	16041-10000-23998	850 S CRENSHAW BLVD	90005	4	132B189   661	5092002031	R3-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM	09/19/2016 12:00:00 AM		Permit Finaled	02/26/2018 12:00:00 AM	ADDRESS	34.05763	-118.32112	Plan check for power and Title 24.  New five story 44 unit apartment, with one level of subterranean garage.  Total  area = 29,743 sq. ft. (indoor) + 7,477 sq. ft. (outdoor).  New 1,400 A service.  17 typical units.     Building permit #15010-10000-01399	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76550	17041-10000-31796	19500 W PLUMMER ST Suite E1	91324	12	198B117    70	2761036058	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			09/06/2017 12:00:00 AM			Verifications in Progress	03/15/2018 12:00:00 AM	ADDRESS	34.2426	-118.55846	PC FOR RETAIL TI (CHANGE OF USE FROM RETAIL TO GYM) TOTAL CONNECTED LOAD <400APC FOR TITLE 24 ENERGY ONLYTOTAL AFFECTED AREA 19763 SQ.FT.SCOPE INCLUDES NEW PANELS, EQUIPMENT, CIRCUITS LIGHTS AND RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76551	13041-20000-25158	4044 S REDWOOD AVE	90066	11	108B153   647	4230009013	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Apartment			09/12/2013 12:00:00 AM	11/18/2013 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	33.99221	-118.44123	PC FOR POWER AND ENERGY.ENERGY FOR PARKING GARAGE.  LOW RISE RESIDENTIAL. NEW 22 UNIT APARTMENT. FIRE ALARM VARIANCE HAS BEEN FILED. APPLICANT HAS PRE-MADE CHECK. VERIFY FEES DURING PC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76552	16041-20001-36614	18715 W COVELLO ST	91335	3	186B121   252	2118006022	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2016 12:00:00 AM			PC Approved	10/31/2016 12:00:00 AM	ADDRESS	34.20757	-118.54106	10.31.2016 - Existing solar system on property, check plans to account for contribution of existing system on/with new system. Existing system is (2) 3.8kW ungrounded system. New system is (1) 3kW ungrounded system. (11) 315W pv modules are new, each with a 400W power optimizer.======Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76553	15041-10000-04252	8514 N REMICK AVE	91352	6	192B165   190	2634022014	RS-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2015 12:00:00 AM	02/12/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.22533	-118.39942	PV1.  Install 4.25 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan - simplified.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76554	18041-20000-31332	900 N WILCOX AVE	90038	13	144B185  1195	5533021014	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Apartment			08/17/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Finaled	05/13/2020 12:00:00 AM	ADDRESS	34.08728	-118.33077	Plan check for new Apartmet building 4 story with 17 units appartment. Total area: 10069 sq ft B#17010-20000-05046Fire alarm variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76555	19041-10000-23514	1305 S OCEAN FRONT WALK	90291	11	108A143   405	4226006002	C1-1-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			06/19/2019 12:00:00 AM	06/20/2019 12:00:00 AM		Permit Finaled	08/01/2019 12:00:00 AM	ADDRESS	33.98831	-118.47476	pc (energy only) for 1st floor (TI). area of scope 710sf.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76556	11041-20000-20233	265 S KINGSLEY DR	90004	4	135B193   179	5517019030	P-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Expired	12/12/2013 12:00:00 AM	ADDRESS	34.06934	-118.30308	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76557	12041-10000-09732	688 S BERENDO ST	90005	10	132B197   183	5094008023	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Apartment			05/07/2012 12:00:00 AM	10/25/2012 12:00:00 AM		Permit Finaled	07/10/2014 12:00:00 AM	ADDRESS	34.06036	-118.29399	PLAN CHECK POWER AND ENERGY NEW 7-STORY APT BLDG W/ 2 LEVELS OF SUBTERRANEAN PARKING GARAGES. 3000A SERVICE. SITE LOCATED IN METHANE BUFFER ZONE.NOT A HIGH RISE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76558	17041-20000-38682	15115 W ROXFORD ST	91342	7	228B145   808	2502027***	(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			10/26/2017 12:00:00 AM	11/21/2017 12:00:00 AM		Re-Activate Permit	08/23/2018 12:00:00 AM	ADDRESS	34.31955	-118.46279	PV1.  Install roof mounted PV system sized 5.2kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76559	16041-10000-45829	2131 W COLORADO BLVD	90041	14	162A223    98	5671010003	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/10/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.13937	-118.21279	Plan check for power and Title 24.  Core and shell renovation of 1 story mercantile building.  New 800 amp 240 volt service.CORE AND SHELL RENOATION OF A TYPE V-B  1 STORY (WITH MEZZANINE) 4719 SF EXISTING COMMERCIAL BUILDING ; REPLACEMENT OF (E) STOREFRONT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76560	19041-20001-28675	7946 N ETHEL AVE pv1	91605	2	189B161   465	2303018052	(T)R1-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	1 or 2 Family Dwelling			07/25/2019 12:00:00 AM			PC Approved	08/21/2019 12:00:00 AM	ADDRESS	34.21527	-118.41607	expeditepv1install roof mounted pv system sized 11.2KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76561	17041-10001-30101	2049 N SICHEL ST	90031	1	136-5A223 114	5210010043	RD2-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1998.00	Electrical	Electrical	1 or 2 Family Dwelling			09/25/2017 12:00:00 AM	09/25/2017 12:00:00 AM		Permit Finaled	10/31/2017 12:00:00 AM	ADDRESS	34.06904	-118.2132	$0 permit fee due to senate bill 1222 from 2012PC FOR CHANGES TO APPROVED SET OF PLANS. REDUCTION IN SYSTEM SIZE. NOW USING 8 MODULES WITH 3KW INVERTER. PC ONLY. PERMIT COVERED UNDER MASTER APP. system size now only 3kw AC.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76562	16041-20000-44881	16702 S VERMONT AVE	90247	15	066B197    92	6121008038	C2-1	Harbor	Harbor Gateway	Harbor Gateway North		2912.20	Electrical	Electrical	Commercial			12/21/2016 12:00:00 AM	01/03/2017 12:00:00 AM		Permit Finaled	06/05/2023 12:00:00 AM	ADDRESS	33.87938	-118.29102	Plan check for installation of solar pv array, roof-mounted on commercial building. Interconnect with a 200A MSP. 3.8kW ungrounded system. (15) 300W pv modules. Each module has a 300W power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76563	10041-20000-02495	6712 W HILLPARK DR	90068	4	154-5A185  12	5549004***	RE15-1-H, RE40-1-H-RPD	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			02/11/2010 12:00:00 AM	02/11/2010 12:00:00 AM		Permit Finaled	05/06/2010 12:00:00 AM	ADDRESS	34.11783	-118.33882	Replacing existing exit sign with combination of emergency and exit sign in four floor apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76564	13041-10000-24793	833 S WALL ST	90014	14	126A211   208	5145011015	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM			PC Approved	09/10/2013 12:00:00 AM	ADDRESS	34.03956	-118.25128	TITLE 24 PLAN CHECK ONLY. REMOVE HID LIGHT FIXTURES AND INSTALLING NEW FLUORESCENT FIXTURES. EMERGENCY LIGHTING EXISTING TO REMAIN. 2688 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76565	19041-20000-22869	11400 W VENTURA BLVD	91604	2	162B173   617	2378021022	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City	YES	1438.00	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Permit Finaled	10/07/2019 12:00:00 AM	ADDRESS	34.13972	-118.37894	ti to an existing commercial building. relocating existing light fixtures.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76566	13041-20001-21835	3114 N DONA ELENA PL PV-1	91604	2	156B169   184	2381025007	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City	YES	1439.01	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2013 12:00:00 AM			PC Approved	08/27/2013 12:00:00 AM	ADDRESS	34.12655	-118.38376	EXPEDITE FEE.PV-1. Plan check for AC modules. Rooftop installation. 5.760kW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76567	17041-20000-41268	1840 S CENTURY PARK EAST SUITE 550	90067	5	135B161    48	4319001904	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/16/2017 12:00:00 AM		Permit Finaled	12/19/2017 12:00:00 AM	ADDRESS	34.06188	-118.41473	PLANCHECK FOR T24 ENERGY.  TI WORK ON 3,770 S.F OF THE TOTAL FLOOR AREA. SUITE 550BUILDING PERMIT: 17016-10000-29845	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76568	17041-20000-31267	15303 W VENTURA BLVD SUITE 1490	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/31/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Issued	08/31/2017 12:00:00 AM	ADDRESS	34.15413	-118.46661	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE SPACE. SUITE 1490. HIGHRISE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76569	13041-10000-25110	3269 E CESAR E CHAVEZ AVE	90063	14	126A229    33	5178025024	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2038.00	Electrical	Electrical	Commercial			09/12/2013 12:00:00 AM			PC Approved	09/25/2013 12:00:00 AM	ADDRESS	34.04083	-118.19394	TITLE 24 PLAN CHECK ONLY. 1271 SQFT. 465 OUTDOOR. EMERGENCY LIGHTING. HARDWARE STORE. 1 STORY BUILDING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76570	15041-10001-01361	200 WORLD WAY TERM 2-ARRV  LEV1	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			03/23/2015 12:00:00 AM			PC Approved	03/23/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	changes to approved set by ADDITION OF 125w INVERTER for emergency lights AND METERING. changes under delta 4. Univision, space 282.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76571	19041-10000-10256	1919 S BURNSIDE AVE	90016	10	126B177   971	5064006001	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			03/21/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.04074	-118.35785	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76572	15041-10000-43194	8365 S WESTLAWN AVE	90045	11	096B161   410	4112028006	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2764.00	Electrical	Electrical	1 or 2 Family Dwelling			12/22/2015 12:00:00 AM	12/22/2015 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	33.96132	-118.40644	PV1 installation to a single family home. Central inverter (6.0 kw) and 17 modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76573	13041-10000-35748	200 WORLD WAY	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/23/2013 12:00:00 AM	05/20/2014 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	33.94558	-118.4039	TI ON 1ST, 3RD AND 4TH LEVEL AND ADDITION ON 4TH LEVEL OF TERMINAL 2 AT LAX.  CONCESSION TI ARE FOR SHELL ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76574	18041-20000-44744	21550 W OXNARD ST Suite 550	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	04/05/2019 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 only. Project site is an existing suite in a commercial high-rise building. Project scope is a tenant improvement. Total lighting area = 2,097 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76575	10041-10000-09296	10912 W LE CONTE AVE	90024	5	135B149   548	4363018001	C4-2D-O	West Los Angeles	Westwood			2653.01	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM	06/04/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	34.06347	-118.4458	TENANT IMPROVEMENTS TO YOGURT SHOP. PLAN CHECK FOR T24 AND ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76576	17041-10000-24758	888 S FIGUEROA ST 500	90017	14	129A207   246	5144021043	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	10/31/2017 12:00:00 AM		Issued	10/31/2017 12:00:00 AM	ADDRESS	34.0465	-118.26225	Energy plan check for an office T.I located in a high rise building. Scope including new lighting and equipment. Total area is 4,535 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76577	14041-10001-14238	5732 N MURIETTA AVE	91401	2	174B153   408	2246018001	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			05/29/2014 12:00:00 AM			PC Approved	06/09/2014 12:00:00 AM	ADDRESS	34.17487	-118.43873	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 6.12 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. WITH OPTIMIZERS AND TRANSFORMERLESS INVERTER.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76578	15041-20000-30781	333 S HOPE ST STE 3750	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	09/28/2015 12:00:00 AM		Permit Finaled	11/30/2015 12:00:00 AM	ADDRESS	34.05326	-118.25292	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES. 2636 SQFT. SUITE 3750.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76579	19041-10000-33531	1969 E ZONAL AVE BSEMNT-B20,21	90033	14	133-5A225   2	5201006024	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			08/26/2019 12:00:00 AM	03/26/2020 12:00:00 AM		Permit Finaled	10/23/2020 12:00:00 AM	ADDRESS	34.06159	-118.20463	Energy plan check for an office T.I. located in the basemen of commercial building. Scope includes new lighting and equipment with a total lighting area of 836-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76580	13041-10000-32600	14955 W SATICOY ST 1-106	91405	6	186B145    79	2209038048	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Apartment			11/20/2013 12:00:00 AM			Reviewed by Supervisor	12/13/2013 12:00:00 AM	ADDRESS	34.20859	-118.45912	PV2. ROOFMOUNTED SOLAR SYSTEM FOR AN APARTMENT COMPLEX. 6 STRINGS. NEGATIVELEY GROUNDED.(336) ECOSOLARGY (1) SOLECTRIA PVI-75KW	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76581	15041-20000-34346	601 S FIGUEROA ST 42ND FL	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/15/2015 12:00:00 AM	12/10/2015 12:00:00 AM		Permit Finaled	04/29/2016 12:00:00 AM	ADDRESS	34.05076	-118.25881	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR CORRIDORS AND RESTROOMS ON 42ND FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76582	12041-20001-31113	3584 S FIGUEROA ST	90007	9	118-5A201  44	5123022026	(T)(Q)C2-2D	South Los Angeles	Southeast Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/28/2012 12:00:00 AM			PC Approved	01/08/2013 12:00:00 AM	ADDRESS	34.01871	-118.28174	New restaurant.  First time tenant.  Full Plan Check required. Title 24 done on 12041-20000-31113. Permit on 12041-10000-30222.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76583	13041-20000-19574	1723-1725 N LUCILE AVE	90026	4	145-5A203 139	5429016010	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1954.00	Electrical	Electrical	1 or 2 Family Dwelling			07/24/2013 12:00:00 AM	08/16/2013 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.09379	-118.27675	SUPPLEMENTAL TO #07010-10000-05482 TO COMPLETE WORK STARTED (60% COMPLETE PER INSPECTION) building A building B sould be submitted to plan check for future	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76584	15041-10001-21541	14006 W RIVERSIDE DR #18	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO, QC2-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			04/29/2016 12:00:00 AM	04/29/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.15713	-118.43792	04/29/16Changes to an approved set of plans, Note changes on the clouded areas, changes include new receptacles for mirror lighting, added fixtures, and receptacles. (((Plan check for Tilte 24 only for hair salon. Total indoor area: 1,639 sqft)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76585	17041-10000-32414	415 S OCCIDENTAL BLVD 1-15	90057	1	135A201    18	5155010013	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Apartment			09/11/2017 12:00:00 AM	12/12/2017 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.06581	-118.28359	PC FOR PV SYSTEM ON APARTMENT BUILDING. TOTAL SIZE 15.4KW AC/ 20.4KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76586	15041-10000-14620	700-800 WORLD WAY TERMINAL 7-8	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/13/2015 12:00:00 AM	07/29/2015 12:00:00 AM		Permit Finaled	03/14/2018 12:00:00 AM	ADDRESS	33.94286	-118.39982	UTILITY CONNECTIONS BETWEEN THE PLBS, RAMP EQUIPMENT, AND THE TERMINAL. WORK UNDER PACKAGE 4. TITLE 24 FORMS TO BE SUBMITTED. FULL PC, PC FOR ENERGY AND POWER. TOTAL SQ. FT. 3630. FEES PER APPLICANT, NEED TO BE CHECKED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76587	17041-10001-36303	7827 N CANTALOUPE AVE	91402	6	189B157   688	2214014002	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	1 or 2 Family Dwelling			10/19/2017 12:00:00 AM			PC Approved	10/19/2017 12:00:00 AM	ADDRESS	34.2129	-118.43156	CHANGES TO APPROVED SET TO REFLECT FIELD INSTALLTION. SCOPE INCLUEDES CHANGE OF ROOF LAYOUT. THIS IS PLAN CHECK ONLY! PERMIT PULLED UNDER MASTER. PV ROOF MOUNTED SYSTEM USING CENTRAL INVERTER. (1) 3.0KW INVERTER AND 8 MODULES. TOTAL SYSTEM SIZE IS 3KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76588	13041-20000-01810	9801 N SYLVIA AVE PV-1	91324	12	201B117   230	2762003016	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	05/02/2013 12:00:00 AM		Permit Finaled	07/02/2013 12:00:00 AM	ADDRESS	34.2487	-118.55261	SOLAR SINGLE FAMILY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76589	18041-20000-18034	20736 W SPRUCE CIR (#80)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	01/02/2019 12:00:00 AM	ADDRESS	34.29482	-118.58587	Plan check for a PV1 roof-mounted PV system. System size is 3.84 kWac and consists of (12) AC PV modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76590	16041-10001-03096	621 W 83RD ST	90044	8	099B201  1360	6032021001	R3-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			02/19/2016 12:00:00 AM			PC Approved	02/19/2016 12:00:00 AM	ADDRESS	33.96332	-118.28483	02/19/2016CHANGES TO AN EXPRESS PERMIT. MODULES WERE REDUCED FROM 20 TO 16 MODULES. INSPECTION FEES WERE PAID UNDER EXPRESS PERMIT #16041-90000-03096.((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76591	13041-10000-30905	12945 W CORCORAN ST	91340	7	216B161   135	2514010059	R1-1	North Valley	Arleta - Pacoima	Pacoima		1042.01	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2013 12:00:00 AM	01/21/2014 12:00:00 AM		Permit Expired	02/16/2016 12:00:00 AM	ADDRESS	34.28907	-118.4152	PV1, Install 4 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 3800A-US. 16 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76592	19041-10001-28168	19340 W RINALDI ST	91326	12	210B117    25	2822019012	C4-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM			PC Approved	11/27/2019 12:00:00 AM	ADDRESS	34.27348	-118.55489	Change of an approved set , change under delta 7 only. chage includes Revision to panel scheduales. *************original scope*******************POWER AND ENERGY PLAN CHECK FOR A TI-CHANGE OF USE FROM GROCERY STORE TO GROCERY STORE WITH TAKE OUT RESTAURANT. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING RECEPTACLES AND CONTROLS. TOTAL CONNECTED LOAD IS MORE THAT 400A FED FROM AN EXISTING 2500A 120/208 3PH 4W SERVICE AND SWEITCHBOARD. TOTAL AFFECTED AREA 26734 SQ.FT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76593	15041-10000-06356	11243 N CHIVERS AVE	91331	7	210B165   228	2532031027	RS-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			03/04/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.27407	-118.40508	PV1, INSTALL  5.8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(18) MODULES: SUNPOWER 327 W ;(1) INVERTER: ABB PVI-6000-OUTD-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76594	14041-10000-22737	1521 W FRANCISCO ST	90501	15	057B193   154	7351021045	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/20/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	33.8496	-118.30518	PLANCHECK FOR T24 ENERGY. OFFICE WITHIN (E) WAREHOUSE SPACE. 300 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76595	14041-10001-28660	750 N HARPER AVE	90046	5	141B173   236	5528006027	R2-1XL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM			Reviewed by Supervisor	12/11/2014 12:00:00 AM	ADDRESS	34.08519	-118.36894	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<<PV1, INSTALL 4.335 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO STORY-HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(17) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3800-US-ZB-U>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76596	15041-20000-02529	19200 S WESTERN AVE	90501	15	057B193     2	7351003013	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/27/2015 12:00:00 AM			PC Info Complete	02/04/2015 12:00:00 AM	ADDRESS	33.85755	-118.30917	PLANCHECK FOR POWER AND ENERGY. TENANT IMPROVEMENT FOR WAREHOUSE.. 148,00 SQFT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76597	12041-10000-26002	535 S GRAND AVE 11, 12 Flr-Penhouse	90071	9	129A209    11	5151026005	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/30/2012 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	07/12/2013 12:00:00 AM	ADDRESS	34.04946	-118.25484	Remodel of exercise and guest rooms in an existing hotel. New ckts and lighting. EPC is for power and energy. (floor 11th, 12th and penthouse). Variance form was filed to seperate the Fire Alarm System.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76598	17041-10000-42201	15926 W ALCIMA AVE	90272	11	129B125   231	4420003008	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2017 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Expired	06/02/2024 12:00:00 AM	ADDRESS	34.05141	-118.53328	PC for new powerwall for four new tesla powerwalls. Installing four new powerwalls and 125A load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76599	14041-20000-33985	3100 N LAKE HOLLYWOOD DR	90068	4	159B181   301	5579025011	R1-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	1 or 2 Family Dwelling			12/08/2014 12:00:00 AM	12/08/2014 12:00:00 AM		Permit Finaled	01/16/2015 12:00:00 AM	ADDRESS	34.13237	-118.34096	pv1central string inverter standard plan sysstem size 6.0kw.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76600	18041-20001-38645	1025-1035 N HIGHLAND AVE	90038	4	144B185   830	5532028004	MR1-1-SN	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	05/10/2023 12:00:00 AM	ADDRESS	34.08969	-118.33884	SUPPLEMENTAL PLAN CHECK FOR INSTALLATION OF A NEW 100A PANEL AND RELOCATION OF EXISTING LOADS FROM EXISTING EM PANEL TO NEW PANEL*original*Demo (E) 125 kW 208Y/120V generator and reconnect (E) loads to (E) 500 kW 480Y/277V generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76601	15041-20002-02895	16719 W SCHOENBORN ST	91343	12	192B137   194	2689013032	M1-1, M2-1, P-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	Commercial			08/10/2015 12:00:00 AM			PC Approved	08/10/2015 12:00:00 AM	ADDRESS	34.22273	-118.49717	08/10/2015 Changes to an approved set of plans. Changes have been clouded and marked as Delta 22. Changes include the recalculation of short circuit current values for all equipment to reflect actual available short circuit current.*****Previous Work Description*****Changes to approved set.  PC at request of inspector.  Emergency lights and exit signs are to be connected to normal circuit instead of inverter (with 90 min battery backup unit equipment).    **********    TENANT IMPROVEMENT FOR BUILD OUT OF NEW OFFICE & SHOWROOM WITHING (E) CORE & SHELL BUILDING.  FIRST TIME TENANT.  PLAN CHECK FOR POWER AND ENERGY.  PC IN ACCORDANE TO 2008 ENERGY DUE TO DATE OF BUILDING SUBMITTALSQUAREFOOTAGE FOR WAREHOUSE UNCONDITION SPACE NOT INCLUDED IN FEES TO BE ADJUSTED AT LATER TIME.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76602	17041-10000-35134	6804 S CENTINELA AVE	90230	11	105B165   427	4220014023	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester - Playa del Rey		2756.03	Electrical	Electrical	Commercial			09/29/2017 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	33.98417	-118.40202	FULL PC FOR NEW INDUSTRIAL BUILDING CONSISTING 1 LEVEL SUBTERRANEAN BASEMENT,GROUND FLOOR AND MEZZANINE TO BE USED AS A WAREHOUSE, OFFICE AND TO STORING AUTOMOBILES; BUILDING IS FULLY SPRINKLERED. 400A 120/208 V SERVICE FROM SOUTHERN CALIFORNIA EDISON.((B# 17010-10000-03765:  PROPOSED  16930 SF INDUSTRIAL BUILDING : 1 LEVEL  BASEMENT,  7650 SF GROUND FLOOR AND 1000 SF 2ND FLOOR TO BE USED AS A WAREHOUSE AND OFFICE; BUILDING IS FULLY SPRINKLEREDSTORING AUTOMOBILESCLEARANCES RELATING TO THE CARLIFTS TO BE HANDLED DURING THE MECH LIFT PLAN CHECK))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76603	14041-20000-30505	13333 N GLENOAKS BLVD	91342	7	225B149   240	2501022025	RA-1-K	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	1 or 2 Family Dwelling			11/03/2014 12:00:00 AM			Reviewed by Supervisor	12/05/2014 12:00:00 AM	ADDRESS	34.31377	-118.45808	PV1Ground mounted solar array, 1.15MW system. Interconnect at DWP vault.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76604	13041-10000-13255	10861 W WEYBURN AVE	90024	5	135B153   493	4363019008	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			05/21/2013 12:00:00 AM			PC Approved	05/31/2013 12:00:00 AM	ADDRESS	34.06247	-118.44344	TENANT IMPROVEMENT TO REMODEL (E) COFFEE BEAN KIOSK AND INSTALL NEW STARBUCK KIOSK (190 SF) AT THE SAME LOCATION AND REMODEL (E) SEATING AREA INSIDE (E) RALPHS MARKET (284 SF; 14 SEATS).PLAN CHJK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76605	12041-10000-27492	861 N LA CIENEGA BLVD	90069	5	144B173   404	4337002048	[Q]C4-2D	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			11/14/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	05/27/2014 12:00:00 AM	ADDRESS	34.08698	-118.37659	TI TO EXISTING RESTAURANT. PLAN CHECK FOR ENERGY. METHANE BUFFER ZONE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76606	16041-10000-24872	753 N OCCIDENTAL BLVD	90026	13	141A203   290	5401027012	RD1.5-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1958.04	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2016 12:00:00 AM	07/18/2016 12:00:00 AM		Permit Finaled	08/19/2016 12:00:00 AM	ADDRESS	34.07992	-118.27404	PV1 ROOF MOUNTED SOLAR SYSTEM USING MICRO INVERTERS. (20) Q.PRO BFR MODULES AND (20) MICRO-INVERTERS ENPHASE M215. TOTAL SYSTEM SIZE 4.3KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76607	12041-20000-06263	6300 N CANOGA AVE 10th Floor	91367	3	180B105    72	2149001033	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.02	Electrical	Electrical	Commercial			03/20/2012 12:00:00 AM	03/20/2012 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.18492	-118.59722	T.I. to high rise building on the 10th floor.  Install general lighting in offices 1012, 1013, and 1014 as indicated on plans.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76608	11041-10000-22463	4155 W BEVERLY BLVD Unit 104	90004	13	138B197   319	5520025006	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1926.20	Electrical	Electrical	Commercial			10/20/2011 12:00:00 AM			PC Approved	10/20/2011 12:00:00 AM	ADDRESS	34.07644	-118.29969	T.I. to an existing retail store.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76609	18041-10000-40831	1744 S INDUSTRIAL WAY	90023	14	117A225   272	5192022014	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.01432	-118.20696	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76610	12041-10000-06924	819 S HOLT AVE 1-7	90035	5	135B173  1010	4333024007	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.00	Electrical	Electrical	Apartment			03/27/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	02/15/2013 12:00:00 AM	ADDRESS	34.06235	-118.37856	Fire alarm system for a new 6-unit apartment complex.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76611	15041-20002-43179	19111 W ARMINTA ST	91335	3	189B121   310	2104006033	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2016 12:00:00 AM			PC Approved	03/30/2016 12:00:00 AM	ADDRESS	34.21392	-118.54963	Modifications to approved plans.  Inclusion of total service load calculation for all occupiable areas on parcel.  $0 plan check fee per Senate Bill SB 1222(((PV1, rooftop solar installation(68) Q Cells G4-260(68) Enpahse M215-60-2LLNote: $0.00 permit fees due to Senate Bill 1222)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76612	19041-20000-43479	821 E 3RD ST	90013	14	129A215   268	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			10/24/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Issued	11/20/2019 12:00:00 AM	ADDRESS	34.04597	-118.23572	TENANT IMPROVEMENT PLAN CHECK FOR TITLE-24 ONLY. TOTAL AFFECTED AREA IS 4065 SQFT. SCOPE OF WORK INCLUDES NEW LIGHTING, CIRCUITS, AND CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76613	15041-20001-44033	1252 W YOSEMITE DR	90041	14	160-5A229 333	5480020024	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			01/04/2016 12:00:00 AM			PC Approved	02/03/2016 12:00:00 AM	ADDRESS	34.13284	-118.19273	*****VOID*****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76614	19041-20000-50528	145 N LAYTON DR	90049	11	135B145   105	4429025008	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/09/2019 12:00:00 AM	07/21/2022 12:00:00 AM		Issued	07/21/2022 12:00:00 AM	ADDRESS	34.06958	-118.47136	INSTALL NEW 1000 AMPS 208V 3PHASE 4WIRE SERVICE WITH PANELS AND EQUIPMENTS FOR (N) 2-STORY SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76615	12041-10000-27928	10767 W RIVERSIDE DR	91602	4, 5	165B177    45	2423001006	C2-1VL	South Valley, West Los Angeles	Palms - Mar Vista - Del Rey, Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Mar Vista, Mid-Town North Hollywood		1431.00, 2717.01	Electrical	Electrical	Commercial			11/20/2012 12:00:00 AM	01/23/2013 12:00:00 AM		Permit Finaled	05/08/2013 12:00:00 AM	ADDRESS	34.15242	-118.3656	T.I.  existing medical office building. Modification is being done in the MRI room.  They are instaling a new MRI machine.  No surgical procedures are to take place.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76616	16041-10000-30442	4001 W VENICE BLVD	90019	10	126B189   214	5072009005	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2181.10	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM	08/26/2016 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.04373	-118.32482	Plan Check for Fire Alarm system for new story building. **NEW 2 STORY TYPE VB SCHOOL BUILDING. K-5TH GRADE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76617	19041-10000-16843	2160 W ADAMS BLVD	90018	10	123B189   697	5052031021	R3-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.01	Electrical	Electrical	Commercial			05/07/2019 12:00:00 AM	05/16/2019 12:00:00 AM		Permit Finaled	06/25/2019 12:00:00 AM	ADDRESS	34.03248	-118.3142	NEW FIRE ALARM SYSTEM IN A COMMERCIAL BULDING WITH 242 DEVICES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76618	18041-10000-43575	7831 W 79TH ST	90293	11	099B153   135	4114006014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.01	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	12/08/2018 12:00:00 AM	ADDRESS	33.96348	-118.43433	ZERO FINAL FEES DUE TO SENATE BILL 1222PLAN CHECK FOR ROOF MOUNTED PV SYSTEM(10KVA AC/13.12DC) CONSISTING OF 1 CENTRAL INVERTER(SE10000H-US) WITH 41 MODULES USING P320 OPTIMIZERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76619	14041-20000-27122	23433 W CALIFA ST	91367	3	177B093   817	2041003003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2014 12:00:00 AM	10/01/2014 12:00:00 AM		Permit Finaled	10/30/2014 12:00:00 AM	ADDRESS	34.17747	-118.6374	PV1Install roof-mounted solar array on SFD. System size: 6.45kW.(30) EnPhase M215-IG microinverters(30) SolarWorld Poly SW250 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76620	18041-10000-28640	14605 W KESWICK ST	91405	6	189B149   582	2210030016	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.10	Electrical	Electrical	Commercial			07/31/2018 12:00:00 AM	07/31/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.21048	-118.45126	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76621	19041-10000-01300	11998 W MISSOURI AVE 1-74	90025	11	123B149   309	4259020900	PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			01/11/2019 12:00:00 AM	02/21/2020 12:00:00 AM		Permit Finaled	11/23/2021 12:00:00 AM	ADDRESS	34.0353	-118.45675	FULL PLAN CHECK FOR POWER AND ENERGY NEW 5 STORY 74 UNIT AFFORDABLE HOUSING. SCOPE OF WORK INCLUDES NEW 2500AMPS SERVICE,120/208 3PH, CIRCUITS EQUIPMENTS AND LIGHTING. TOTAL AFFECTED AREA 43632  SQFT. BLD# 18010-10000-05182	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76622	13041-10001-33018	5732 N ENCINO AVE	91316	5	174B129   416	2254022013	R1-1	South Valley	Encino - Tarzana	Encino		1390.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	01/15/2014 12:00:00 AM	ADDRESS	34.17477	-118.51401	Expedited RSES plan check per applicant request.[][][]PV1, Install 6.75 kw DC roof-mounted solar array for a house, interconnect with the main service panel.(1)Transformerless inverter(s): SolarEdge SE6000A-US. (27) modules: Trina Solar TSM-250PA05.18.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76623	16041-10000-04028	9137 S WESTERN AVE	90047	8	094-5A193 129	6036016051	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2384.00	Electrical	Electrical	Commercial			02/04/2016 12:00:00 AM	02/23/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	33.95351	-118.3092	PC for Power only. Install new  600 A Main SWBD only. ((Tenant panels will be done under tenant work (future)).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76624	14041-20003-02711	10625 N OAKDALE AVE	91311	12	207B113   141	2708020032	A2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			05/08/2014 12:00:00 AM			PC Approved	05/08/2014 12:00:00 AM	ADDRESS	34.26315	-118.5671	Modifications to approved set: addition of solar production meter on load side of AC disconnect per DWP requirements.  $0 submittal fee is due to the 2012 Senate Bill No. 1222(((PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 17KW AC USING 3 TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. CONNECTION TO 400A SERVICE.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76625	16041-10001-45725	355 S GRAND AVE STE 3200	90071	14	130-5A211  22	5151015013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			06/21/2017 12:00:00 AM			PC Approved	06/21/2017 12:00:00 AM	ADDRESS	34.05191	-118.2525	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE TO LITHING CONTROLS. UPDATED FLOOR PLANS AND T24 DOCS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76626	14041-10000-23751	1307 W PICO BLVD	90015	1	127-5A205 147	5137031027	CM-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			08/29/2014 12:00:00 AM	08/29/2014 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.0432	-118.27335	Title 24 plan check only.  Total area = 24,860 sq. ft.Remove HID light fixtures and replace with new LED fixtures.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76627	18041-20001-40552	20280 W VIA CELLINI	91326	12	219B113    88	2701046019	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			12/18/2018 12:00:00 AM			PC Approved	12/18/2018 12:00:00 AM	ADDRESS	34.29295	-118.57557	12-18-2018 Changes to an approved set of plan PV solar. Changes include remove 1 string and reconnected PV Modules to other strings. All Changes has been clouded.Plan check onlyFees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76628	11041-20000-16861	20701 W PLUMMER ST	91311	12	201B109   305	2748003071	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM			PC Approved	08/10/2011 12:00:00 AM	ADDRESS	34.24287	-118.58449	Requested by R.Horn Revisions to 11041-10000-10645  (Ti in a commercial Bldg. Epc is for T24 & Emergency lights.)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76629	18041-10000-21703	5348 N TOPANGA CANYON BLVD	91364	3	171B101   322	2169003051	C2-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.02	Electrical	Electrical	Commercial			06/12/2018 12:00:00 AM	06/12/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.16733	-118.60556	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76630	13041-10000-34450	6216 N MAMMOTH AVE	91401	2	177B157   341	2239007067	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM	01/17/2014 12:00:00 AM		Permit Finaled	01/29/2014 12:00:00 AM	ADDRESS	34.18355	-118.43217	PV1, Install a 4.5 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE5000A-US] and (18) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76631	15041-10000-17006	5815 S NORMANDIE AVE STE D	90004	11	108B145  1466	4241037012	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			06/03/2015 12:00:00 AM	06/03/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	PIN	33.99013348	-118.46132257	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH NEW LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76632	18041-20000-12441	14558 W SYLVAN ST	91411	6	178-5A151 144	2241012025	[Q]C1.5-1VL-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.03	Electrical	Electrical	Commercial			04/06/2018 12:00:00 AM	04/16/2018 12:00:00 AM		Permit Finaled	05/01/2018 12:00:00 AM	ADDRESS	34.1845	-118.45074	Plan check for Title 24 only in existing space office. T.I. office space retrofit of the lighting fixtures(Modification in Place). Total area: 8,665 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76633	19041-10000-14319	3755 S CANFIELD AVE 1-7	90034	5	120B165   456	4313020033	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM	05/02/2022 12:00:00 AM		Issued	05/02/2022 12:00:00 AM	ADDRESS	34.02674	-118.39506	FPC FOR A NEW  BUILDING.  SCOPE INCLUDES (1) 800-AMP PULL SECTION SUPPLYING (2) 400-AMP BOARDS WITH 3-PH 120/240VTOTAL AFFECTED AREA (IN+OUT) 10,250SQ.FTB# 19020-30000-00987	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76634	18041-10000-24003	1409 N SPAULDING AVE	90046	4	147B177  1221	5551023002	R1-1-HPOZ	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	1 or 2 Family Dwelling			06/27/2018 12:00:00 AM	06/27/2018 12:00:00 AM		Permit Finaled	08/28/2018 12:00:00 AM	ADDRESS	34.09647	-118.35722	PC FOR ROOF MOUNETED PV ON SFD. SYSTEM SIZE 9.92KWAC /11.16 KWDCSCOPE INCLUDE 31 AC MODULES WITH NEW LOAD CENTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76635	19041-10000-04569	800 W 6TH ST	90017	14	130-5A209 195	5144007400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/07/2019 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	11/05/2019 12:00:00 AM	ADDRESS	34.05011	-118.2577	PLAN CHECK FOR TITLE 24 ONLY ON 9TH FLOOR RESTROOM AND ELEVATOR LOBBY. TOTAL EFFECTED AREA 965 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76636	15041-10000-19563	1319 N MARTEL AVE	90046	4	144B181    48	5550020025	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	Apartment			06/22/2015 12:00:00 AM	06/03/2016 12:00:00 AM		Permit Finaled	05/17/2017 12:00:00 AM	ADDRESS	34.09499	-118.35087	FULL PC, NEW 23 UNIT 4 STORY APARTMENT BUILDING. NEW 1-1200 AMP SERVICE  PC FOR POWER AND ENERGY. TOTAL SQ FT. 18000. FEES PER APPLICANT AND M.ZNO FIRE ALARM VARIANCE ON FILE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76637	14041-10000-02635	920 S CROCKER ST 1-9	90021	14	124-5A211 160	5132002018	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			01/30/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	12/22/2014 12:00:00 AM	ADDRESS	34.03569	-118.24958	"NEW  2-STORY 9 WHOLESALE STORE WITH MEZZ (3696 SQ.FT.) AND ROOFTOP PARKING/ OFFICE AND STORAGE ROOM. ""COMPLY WITH DEPARTMENT ORDER effective date12/19/2012. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""][][] PLAN EXPEDITED. THIS PLAN WAS ORIGINALLY SUBMITTED WITHOUT EXPEDITING. APPLICANT RETURNED TO REQUEST PLAN TO BE EXPEDITED. PLEASE SEE SUBMITTAL-2 FOR EXPEDITING FEE ][][]"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76638	17041-20000-00433	7541 W FOOTHILL BLVD	91042	7	204A197   312	2558029022	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1012.10	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	01/06/2017 12:00:00 AM		Permit Finaled	02/03/2017 12:00:00 AM	ADDRESS	34.25372	-118.29652	Plan check for Title 24 only. Project site is an existing commercial space (car wash).  Project scope is a tenant improvement. Total lighting area = 10,180 sq. ft.Note: Building permit has been pulled under 16016-10003-28247	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76639	16041-20002-31964	5200 S CENTRAL AVE	90011	9	108B209    95	5104003034	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM			PC Approved	05/11/2018 12:00:00 AM	ADDRESS	33.99574	-118.25623	Revisions to approved set of plans.  Change of inverter type to SolarEdge system.  Modifications to roof layout of solar modules.  AC rated max output changed from 56 kWAC to 66 kWAC.  (((Plan check for the roof-mounted portion of a PV2 roof-mounted & ground-mounted PV system. PV is part of the LADWP feed in tariff (FIT) program. Roof-mounted portion is 56 kWac and consists of (2) 28 kWac inverters and (226) modules. Total system size is 323 kWac.  Note: Ground mounted portion of the PV2 PV system can be found under application number 16041-20000-31971)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76640	19041-10000-46050	9850 N OWENSMOUTH AVE	91311	12	201B105    75	2746005007	MR1-1, [Q]MR1-1, [Q]P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			11/08/2019 12:00:00 AM			PC Info Complete	11/08/2019 12:00:00 AM	ADDRESS	34.24952	-118.60152	T-24 PLAN CHECK FOR AN INTERIOR TENANT IMROVEMENT OF EXISTING SPACE. SCOPE INCLUDES NEW RECEPTACLES, LIGHTING AND CONTROLS. TOTAL AFFECTED AREA IS 1581 SQ.FT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76641	16041-10006-38144	10515 N BALBOA BLVD	91344	12	207B133   792	2695009027	CR-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM			PC Approved	02/26/2019 12:00:00 AM	ADDRESS	34.26153	-118.50259	PC only for pv , change include delta 6 (Isc calc ) . original PC # 16041-30000-38144	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76642	18041-10000-33323	1701 N GLENDALE BLVD	90026	13	142-5A209  58	5423007025	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Echo Park	YES	1955.00	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.08609	-118.26007	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76643	10041-10000-04626	4451 W BEVERLY BLVD	90004	13	138B193   471	5521030023	C2-1	Central	Wilshire	Wilshire Center - Koreatown		1925.10	Electrical	Electrical	Commercial			03/15/2010 12:00:00 AM			PC Info Complete	03/16/2010 12:00:00 AM	ADDRESS	34.07639	-118.30562	T.I. for a restuarant.  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76644	17041-20001-17757	801 N BROOKTREE ROAD	90272	11	126B129   239	4409020011	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			05/26/2017 12:00:00 AM			PC Approved	06/06/2017 12:00:00 AM	ADDRESS	34.04378	-118.51433	Expedite fee	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76645	16041-20000-25825	10300 W WILSHIRE BLVD	90024	5	135B157   117	4327013027	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			07/21/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Expired	09/14/2018 12:00:00 AM	ADDRESS	34.06768	-118.42561	"600 AMP BOARD ADDITION TO ""MSB"" RECONNECTING ALL FEEDERS.  ADDITION OF 50KVA XFORMER TO RECONNECT EXISTING ELEVATOR PANEL.PLAN CHECK FOR POWER ONLY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76646	14041-10000-20911	3000 S HOOVER ST	90007	9	121-5A201 144	5123005031	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			08/04/2014 12:00:00 AM			PC Info Complete	08/05/2014 12:00:00 AM	ADDRESS	34.02712	-118.28376	PC for t24 only. Scope of the job is restroom in usc fire station. total area 214 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76647	17041-20000-22605	1722 E 16TH ST	90021	14	120A213   207	5167002033	MR2-2	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	10/20/2017 12:00:00 AM	ADDRESS	34.02315	-118.24168	Plan check for Fire alarm only. Installation of new fire alarm system for existing commercial building (club).1 FACP. 29 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76648	17041-20000-13373	23635 W COMMUNITY ST	91304	12	192B093   181	2005018015	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2017 12:00:00 AM	04/24/2017 12:00:00 AM		Permit Finaled	06/03/2017 12:00:00 AM	ADDRESS	34.2218	-118.64238	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 7KW INTERCONNECTED  WITH MSP.  STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76649	13041-10000-14631	16012 W MEADOWCREST ROAD	91403	5	162B141   486	2280019024	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2013 12:00:00 AM	08/08/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.13657	-118.48212	PV1 16.35KW XFMR  INV. 1 STORY HOUSE. NONSTD. ROOFMOUNT.   [INV: SUNPOWER SPR-10001F and supower spr-6501F ][MOD: sunpower SPR-327NE-wht-d ]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76650	10041-10000-11071	25820 S VERMONT AVE	90710	15	033B197     9	7412010903	OS-1XL-O	Harbor	Wilmington - Harbor City	Harbor City, Wilmington		2944.20	Electrical	Electrical	Commercial			06/10/2010 12:00:00 AM	08/05/2010 12:00:00 AM		Permit Finaled	02/10/2011 12:00:00 AM	ADDRESS	33.78902	-118.29358	NEW RESTROOM FACILITY at a regional parkplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76651	10041-20000-19309	19821 W RINALDI ST	91326	12	213B113   305	2701040033	C2-2D, C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			09/28/2010 12:00:00 AM	09/30/2010 12:00:00 AM		Permit Finaled	09/19/2014 12:00:00 AM	ADDRESS	34.27548	-118.56626	Plan check for indoor illuminated LED sign for McDonald's inside Walmart. Permit to install power to LED sign. Existing circuit. No building permit required for inside Walmart sign.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76652	12041-20000-05630	5750 W WILSHIRE BLVD 2ND FLR-023	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM	04/03/2012 12:00:00 AM		Permit Finaled	08/09/2012 12:00:00 AM	ADDRESS	34.06227	-118.3542	TENANT IMPROVEMENT OFFICE,  partial 2nd flr, suite 023,  ~600 sq  feet.  Plan check only for T-24, Permit for 5 circuits, 9 lights, and 7 switches.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76653	13041-10000-12814	12852 W RUNWAY ROAD	90094	11	102B161  1221	4211033040	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM	02/05/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	33.97543	-118.41892	"Methane mitigation system for a new 2-story community center.  New methane mitigation system panel with 36 devices. Overrided #1 due to this note ""The application number already has timekeeping associated with it. Therefore its association with a project or event code cannot be changed without manually adjusting pcis, pcam and citwide payroll. financial services needs to be contacted."""	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76654	18041-10000-14578	15100 W VENTURA BLVD	91403	4	168B145  1071	2276006021	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			04/20/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Issued	05/25/2018 12:00:00 AM	ADDRESS	34.15292	-118.46192	PC FOR BANK TI FOR TITLE 24 ENERGY ONLY. TOTAL AFFECTED AREA  19530  SQ.FT REPLACING EXISTING LIGHTS WITH UL LISTED RETROFIT LED KIT. EXISTING EMERGENCY LIGHTS AND SWITCHING TO REMAIN.INDOOR AND OUTDOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76655	10041-10001-05331	1000 S HOPE ST GND FL	90015		127-5A207 174	5139008019	[Q]R5-4D-O		Central City	Downtown Los Angeles			Electrical	Electrical	Commercial			04/09/2010 12:00:00 AM			PC Info Complete	06/08/2010 12:00:00 AM	ADDRESS	34.04346	-118.2617	ADDITION TO EXISTING SWITCHGEAR FOR A HIGH RISE BUILDING  THREE FEEDERS ( 400A CB & 2EA 200A  CB) TO SUPPLY NEW PANELBOARDS THROUGH NEW XFMRS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76656	13041-10000-30106	7320 N HESPERIA AVE	91335	3	186B125   806	2121003014	R1-1	South Valley	Reseda - West Van Nuys	Reseda		1318.00	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/26/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.2037	-118.5261	PV1, Install 11.75 kW DC roof-mounted photovoltaic system, interconnect with service panel. Multiple transformerless inverters. 47 modules HANWHA # HSL60P6-PB-4-250TW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76657	16041-20000-22277	687 N AMALFI DR	90272	11	126B129   604	4408018013	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.02	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2016 12:00:00 AM			PC Approved	08/24/2016 12:00:00 AM	ADDRESS	34.04039	-118.51193	Plan check for power New Single Family Dwelling 600A service and associated loads.PERMIT PAID UNDER BUILDING APPLICATION #: 14010-30000-01338	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76658	16041-10000-24446	601 W 5TH ST 215, 217	90071	14	130-5A211  96	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	09/06/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.05049	-118.25386	TENANT IMPROVEMENT TO OFFICE SUITE 215 AND 217  NO CHANGE OF USE.  PC FOR T-24 ONLY, TOTAL AFFECTED AREA: 2170 SQ.FT.B# 16016-10000-12914	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76659	16041-10000-44670	3712 N BARHAM BLVD Building C	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	11/14/2018 12:00:00 AM	ADDRESS	34.14094	-118.34145	"WORK FOR BUILDINGS A,B,C,D,E,F,G,H,J,K,L,M, &NINSTALLATION OF NEW ""STACKED"" WASHERS & DRYERS, UPGRADING UNIT PANELS. ADDING CIRCUIT FOR THE WASHER DRYER UNITS.THIS PC IS FOR BUILDING C"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76660	13041-20000-15783	12653 N DORINA PL	91344	12	219B133    47	2602019007	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			06/14/2013 12:00:00 AM	06/14/2013 12:00:00 AM		Permit Expired	02/27/2014 12:00:00 AM	ADDRESS	34.30071	-118.50536	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.7 KW. USING 17 MODULES MICROINVERTER STANDARD PLAN. ENPHASE M215.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76661	17041-30000-21203	415 N FIGUEROA ST	90744	15	027B201     9	7417002032	[Q]M2-1VL-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2949.00	Electrical	Electrical	Commercial			06/22/2017 12:00:00 AM	06/22/2017 12:00:00 AM		Permit Finaled	05/25/2018 12:00:00 AM	ADDRESS	33.77391	-118.27885	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 8,939 sq. ft.Note: Building application has been generated under 17016-10000-07376	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76662	15041-20000-26546	6040 W CENTER DR	90045	11	102B169    76	4104001081	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Commercial			08/14/2015 12:00:00 AM	09/17/2015 12:00:00 AM		Permit Closed	08/12/2016 12:00:00 AM	ADDRESS	33.97574	-118.39042	Plan check for the installation of service equipment for temporary power. Work includes a 2000-amp service, (10) panels, associated loads, (1) transformer, and (1) elevator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76663	15041-10001-38784	600 WORLD WAY SPACE 680	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/15/2016 12:00:00 AM			PC Approved	04/15/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 4 REVISIONS. UPDATED KIOSK NUMBER AND SERIES RATING INFO. - NO CHANGES TO T24. PLAN TO BE RESTAMPED WITH CORRECTED NOTES FOR INSPECTOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76664	18041-20000-35548	12964 W PANAMA ST	90066	11	105B157   569	4223008013	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM	02/08/2019 12:00:00 AM		Permit Finaled	03/24/2020 12:00:00 AM	ADDRESS	33.9839	-118.42804	Plan check for First Time Tenant Gym(Fitness Room) and Bicycle storage room in parking structure. Total area: 2,420 sq ft. B#16010-10000-03938	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76665	10041-10000-18996	10950 W PALMS BLVD	90034	11	120B161  1306	4252017035	R3-1	West Los Angeles	Palms - Del Rey - Mar Vista	Mar Vista		2718.02	Electrical	Electrical	Apartment			09/23/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	07/09/2012 12:00:00 AM	ADDRESS	34.02117	-118.41798	"NEW 4-STORY TYPE V-1 HR APARTMENT(10 UNITS) OVER TYPE I PARKING GARAGE.SPRINKLERS THRU-OUT."" power, lighting and energy"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76666	11041-10000-24098	3880 N MISSION ROAD 1st Floor	90031	1	138A227   208	5211019024	M1-1	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1991.20	Electrical	Electrical	Commercial			11/09/2011 12:00:00 AM	02/29/2012 12:00:00 AM		Permit Finaled	07/17/2012 12:00:00 AM	ADDRESS	34.07149	-118.19797	"1st floor TI of ""FOREVER 21"" building (Phase II). Core & Shell & Phase I were submitted under different applications. Plan check for Power & Energy."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76667	09041-10003-04397	1327 E 21ST ST	90011	9	120A211   274	5119001021	[Q]R4-1	South Los Angeles	Southeast Los Angeles	Southeast / Central Avenue		2270.10	Electrical	Electrical	Commercial			04/29/2011 12:00:00 AM			Corrections Issued	04/29/2011 12:00:00 AM	ADDRESS	34.02205	-118.25153	MODIFICATION TO THE OUT DOOR TITLE 24 FOR PCIS # 09041-10001-04397.  THE MODICATIONS ARE TO THE WATTAGE OF THE FIXTURES AS WELL AS THE ADDITION OF 2 LIGHTING FIXTURES.  TITLE 24 PLAN CHECK ONLY. <<<<<<Delta 2 revisions to permitted set of plans- revised lighting plans and tile 24 compliance forms; reduced loads supplied from panel 1la and show it on the schedule and on the single line diagram; added and deleted a few receptacle. All changes are bubbled on the plans and identified with a delta 2 marking>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76668	13041-20000-23893	4638 E NORELLE ST	90032	14	138A231   130	5215038009	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2014.02	Electrical	Electrical	1 or 2 Family Dwelling			09/03/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	09/25/2013 12:00:00 AM	ADDRESS	34.0719	-118.18336	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.8 KW USING 13 MODULES. USING ENPHASE MICROINVERTER M215. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76669	13041-10000-00606	127 S SAN VICENTE BLVD 7th FL	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			01/09/2013 12:00:00 AM			PC Approved	03/21/2013 12:00:00 AM	ADDRESS	34.07457	-118.37864	T.I. OF OFFICE SPACE ON THE 7TH FLOOR OF AN OFFICE BUILDING HIGHRISE. NON MEDICAL LOCATION. COUNTER CHECK FOR T24 COMPLIANCE AND INSPECIAL FOR NEW BRANCH CIRCUIT LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76670	19041-20000-20041	2719 S MCCONNELL DR	90064	5	126B165   212	4308006004	R1V2-O	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	07/17/2019 12:00:00 AM	ADDRESS	34.04395	-118.40318	PLAN CHECK FOR NEW ROOFTOP MOUNTED PV SYSTEM ON EXISTING ADU. SYSTEM SIZE IS 5.76KW DC/5.04KW AC. SCOPE OF WORK INCLUDES (16) SUNPOWER SPR-X22-360-E PV MODULES WITH INTEGRATED MICRO INVERTERS, AND A NEW 100A SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76671	17041-20000-21241	5670 W WILSHIRE BLVD 22ND FLOOR	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	09/11/2017 12:00:00 AM	ADDRESS	34.06222	-118.35208	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR BATHROOMS ON 22ND FLOOR. 442 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76672	15041-20000-01269	4280 N JUBILO DR	91356	3	165B121   295	2177020015	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2015 12:00:00 AM	01/27/2015 12:00:00 AM		Permit Finaled	05/01/2015 12:00:00 AM	ADDRESS	34.14926	-118.54292	PV1. ROOFMOUNTED SOLAR SYSTEM.  SYSTEM SIZE: 8.48 KW. CENTRAL INVTERTED AND MICROINVERTER SYSTEM(32) SUNEDISON SE-F265(16) ENPHASE M250(1) SMA SB3800	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76673	14041-20001-03431	16442 W GUNTHER ST	91344	12	213B137   120	2610020025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	1 or 2 Family Dwelling			02/06/2014 12:00:00 AM			PC Approved	03/25/2014 12:00:00 AM	ADDRESS	34.28347	-118.49027	Expedite Fee ONLY****Roof mounted PV system with 6KWdc.****	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76674	14041-20001-07790	14053 N SADDLE RIDGE ROAD	91342	7	228B141    24	2582033043	R1-1	North Valley	Sylmar	Sylmar	YES	1065.10	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2014 12:00:00 AM			PC Approved	04/28/2014 12:00:00 AM	ADDRESS	34.32559	-118.48252	(((expedite fees)))pv1 single family dwelling. total system size 3.8 kw ac using transformerless inverter nonstandard plan. using power optimizers.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76675	13041-10001-14687	6112 W SUNSET BLVD	90028	13	147A189    59	5546024019	C4-2D-SN	Central	Hollywood	Hollywood Studio District		1908.01	Electrical	Electrical	Commercial			07/18/2013 12:00:00 AM			PC Approved	08/08/2013 12:00:00 AM	ADDRESS	34.09785	-118.32289	TITLE 24 PLAN CHECK UNDER INSPECTOR REQUEST. EXPRESS PERMIT WAS OBTAINED UNDER 13041 10000 14687 .       {{{{{{{{INSTALL (25) OUTLETS & (20) LIGHTS FIXTURES.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76676	18041-10000-42142	4610 S MAIN ST 1st floor	90037	9	112-5A205 280	5109002051	C2-1VL	South Los Angeles	Southeast Los Angeles	Zapata-King		2285.00	Electrical	Electrical	Commercial			11/02/2018 12:00:00 AM			PC Info Complete	11/02/2018 12:00:00 AM	ADDRESS	34.00159	-118.27377	Energy plan check for a new teacher lougne and an existing classroom with a total area of 689-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76677	15041-20000-03269	21820 W BURBANK BLVD SUITE 230	91367	3	174B105    44	2146007121	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			02/03/2015 12:00:00 AM	02/13/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	ADDRESS	34.17228	-118.6032	TI TO AN EXISTING COMMERCIAL SINGLE STORY BUILDING.  NEW LIGHTING NEW CONTROLS. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 4481	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76678	12041-10001-27429	11127 W PALMS BLVD	90034	5	117B157    67	4251028030	C2-1VL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.02	Electrical	Electrical	Commercial			01/31/2013 12:00:00 AM			PC Approved	01/31/2013 12:00:00 AM	ADDRESS	34.01963	-118.4218	OWNER DECIDED TO CHANGE LIGHTING SYSTEMPLAN CHK IS FOR TITLE 24T.I. IN EXISTING RESTAURANT.  UPGRADE SERVICE TO 200AMPS. INSTALL NEW PANELBOARDS AND CIRCUITS.  NO CHANGE IN LIGHTING SYSTEM.  (Ok to issue Express per Francis Ysaguirre)  1 OF 2 W/ PERMIT #12042-10000-19425.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76679	17041-10001-31946	900 N ALAMEDA ST 3RD FL	90012	14	133-5A215 345	5409015015	ADP-RIO	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			12/08/2017 12:00:00 AM	02/22/2018 12:00:00 AM		Permit Finaled	03/29/2018 12:00:00 AM	ADDRESS	34.05855	-118.23671	PC for power for new chiller equipment, pump equipment, cicuits and panel. Providing power to panels MCP-HD, MCP-HC, MCP-HA  wich feeds chiller equipment inside manufacturer prefabricated utility room modules  shown in E1.1. Providing power to pump modules located inside manufacturer prefabricated pump room module shown on E2.0. B#17020-10000-02229	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76680	17041-20000-38468	6129 N ST CLAIR AVE	91606	2	177B165   419	2333006017	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM	12/04/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.18205	-118.39994	Plan check for solar pv system w/roof-mounted solar array on SFD.Total system size: 11.52kW ungrounded.(36) 320W AC modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76681	15041-10000-03976	1706-1712 W SUNSET BLVD	90026	13	139-5A209 146	5404017020	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	34.07718	-118.2588	plan check for a Central Station Transmitters only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76682	15041-20001-36201	535 S KINGSLEY DR	90020	10	135B193   769	5503023019	P-1	Central	Wilshire	Wilshire Center - Koreatown		2118.02	Electrical	Electrical	Apartment			08/26/2016 12:00:00 AM			PC Approved	08/26/2016 12:00:00 AM	ADDRESS	34.06428	-118.30317	8.26.2016- Plan check for modifications to approved set. Update unit panels to have 15A breakers with #14AWG conductors for general circuits. Update single line diagram - feeder lengths updated to match actual installed length - updated feeder  conductor sizes and voltage drop percentages to compensate. Change breaker size feeding unit panels to 100A. Changes clouded delta 3.=====PC for power and energy on a New 7-story, 72 unit apartment building over a podium parking level and 1 level of subterrean parking garage.  total area is 72,755 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76683	18041-20000-29935	24202 S ROSCOE BLVD	91304	12	192B089   196	2017039007	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2018 12:00:00 AM	08/08/2018 12:00:00 AM		Permit Finaled	12/14/2018 12:00:00 AM	ADDRESS	34.21939	-118.65406	Plan check for a PV1 roof-mounted PV system. System size is 6.3 kWdc and consists of (1) 5.2 kWac rated inverter and (20) modules. System is being interconnected with a 400-Amp service.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76684	17041-20001-09800	13384 N DRONFIELD AVE	91342	7	225B149   135	2504012006	RA-1-K	North Valley	Sylmar	Sylmar		1064.05	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM			PC Approved	04/04/2017 12:00:00 AM	ADDRESS	34.31524	-118.44653	expedite.pv1install roof mounted pv system sized 10kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76685	19041-10001-41497	10430 N MONTGOMERY AVE	91344	12	207B141   853	2668018016	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM			PC Approved	11/13/2019 12:00:00 AM	ADDRESS	34.26019	-118.48146	FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED 12KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE6000H-US) WITH 48 MODULES USING P320 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76686	16041-10000-27711	9800 S HARVARD BLVD	90047	8	091-5A195  11	6055020027	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			08/04/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	08/22/2016 12:00:00 AM	ADDRESS	33.94663	-118.30665	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 2.915KWdc / 3.8KWac.(11)MODULES-TRINA TSM-265 PD05.08(1)INVERTER-FRONIUS PRIMO 3.8-1	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76687	14041-10000-25152	355 E 1ST ST	90012	14	129A215    13	5161012903	[Q]C4-2D-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	07/02/2015 12:00:00 AM		Issued	07/02/2015 12:00:00 AM	ADDRESS	34.04958	-118.23946	Plan check for title 24 only; new load and equipment have been added on the plan and the load does not exceed 400 amps.  ((( Major portion of fees have been charged under express permit 15041-40000-01486 and fees for supplemental have been charged on master permit 14041-10000-25152))).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76688	13041-10000-05403	11450 W TERRA VISTA WAY	91342	7	213B169   133	2530038012	R1-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	04/30/2013 12:00:00 AM	ADDRESS	34.28366	-118.3815	PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3 KW. USING 14 PANELS. MICRO INVERTER.  ENPHASE M215 USING REC 245 PE SOLAR MODULES. SINGLE STROY DWELLING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76689	11041-10000-16880	1230 W 3RD ST 1st Floor	90017	1	132A209    97	5152014037	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			08/10/2011 12:00:00 AM	08/11/2011 12:00:00 AM		Permit Finaled	03/09/2012 12:00:00 AM	ADDRESS	34.057	-118.259	TI FOR AN EXISTING OFFICE BUILDING.  PLAN CHECK IS FOR ENERGY ONLY. Permit for power lighting, communication, security, and fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76690	17041-20000-18412	20215 W SATICOY ST	91306	3	186B113   166	2114004017	C1.5-1VL, P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	Commercial			06/02/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Issued	07/11/2017 12:00:00 AM	ADDRESS	34.20847	-118.57375	ti ti an existing commercial building.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76691	18041-20000-29308	20744 BUR OAK CIR	91326	12	219B109   360	2761001***	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/03/2018 12:00:00 AM	08/03/2018 12:00:00 AM		Permit Finaled	05/03/2019 12:00:00 AM	PIN	34.29414492	-118.58745412	PV1.  Install 5.03 kW roof mounted grid tied PV system.  (15) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76692	10041-10000-17196	964 S HILGARD AVE	90024	5	132B153    26	4360006015	[Q]R3-1-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			08/31/2010 12:00:00 AM			PC Info Complete	02/17/2011 12:00:00 AM	ADDRESS	34.06204	-118.44136	4 stories, 11 typical units APARTMENT BUIILDING @ 16,116 SF WITH 2 LEVELS OF SUB-TER PARKING GARAGE @ 11,905SF (TOTAL OF 28,021 SF). N NFPA 13 FULLY AUTOMATIC SPRINKLER SYSTEM PROVIDED.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76693	16041-20000-10190	21407 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Approved	03/23/2016 12:00:00 AM	ADDRESS	34.2574	-118.59765	Plan check for energy only. Change use of tenant space from retail to restaurant. Add new lighting in new bathrooms. Add emergency buglights in dining area. 1,004sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76694	14041-20000-16791	9101 N SEPULVEDA BLVD	91343	7	198B145   385	2656026012	C2-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	07/31/2014 12:00:00 AM		Permit Finaled	11/05/2014 12:00:00 AM	ADDRESS	34.23576	-118.4679	Change of use from retail to new expansion of laundromat (1088 SF) to existing laundromat.  Additonal load less than 400A.  Install general/emergency lighting.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76695	18041-10000-48277	3580 W WILSHIRE BLVD 4TH FLR	90010	10	132B193    55	5093026033	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2124.10	Electrical	Electrical	Commercial			12/20/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	03/28/2019 12:00:00 AM	ADDRESS	34.06156	-118.3028	TI IN AN EXITING OFFICE AREA ON THE 4TH FLOOR. T-24 ENERGY ONLY. 4620 SQR FT. BUILDING PERMIT: 18016-10000-30153	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76696	19041-20000-40377	18450 W CALICO LANE	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			10/04/2019 12:00:00 AM	10/07/2019 12:00:00 AM		Permit Finaled	04/08/2020 12:00:00 AM				PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM ON EXISTING SFD. SYSTEM SIZE IS 2.8 KW DC/2.52KW AC. SCOPE OF WORK CONSISTS OF (8) PV MODULES WITH INTEGRATED MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76697	17041-20001-30482	19840 W NORDHOFF PL	91311	12	198B113   221	2761001067	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			12/29/2017 12:00:00 AM			PC Approved	12/29/2017 12:00:00 AM	ADDRESS	34.23566	-118.56581	12/29/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. The PV distribution panel has been relocated from the roof to the side of the building, next to the AC disconnect.*****Previous Work Description*****Plan check for a PV2 roof-mounted feed-in tariff PV project. System size is 200 kWac and consists of (3) inverters, (657) modules, and (1) load center.$0 permit fee due to State Senate Bill SB 1222.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76698	10041-20000-20559	14500 W ROSCOE BLVD UNIT #  2	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			10/15/2010 12:00:00 AM	11/29/2010 12:00:00 AM		Permit Finaled	02/07/2011 12:00:00 AM	ADDRESS	34.22136	-118.44937	PLAN CHECK T24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR T.I. FOR (E) BANK. OUTDOOR LIGHTING FOR ATM EXEMPT. SIGN LIGHTING ON SEPERATE PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76699	14041-20000-25861	5254 N BAZA AVE	91364	3	171B105   490	2168021051	RE40-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.02	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2014 12:00:00 AM	09/30/2014 12:00:00 AM		Permit Expired	10/25/2016 12:00:00 AM	ADDRESS	34.1652	-118.60068	FEE CHARGE IS $0.00 BY STATE SENATE BILL NO. 1222PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 8.8KW INTERCONNECTED WITH MSP.(43) KYOCERA KD255 MODULES(2) SOLAREDGE 5000 AND 3800 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76700	19041-20000-21109	326 N BONHILL ROAD pv1	90049	11	135B141   655	4403016009	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2019 12:00:00 AM	06/04/2019 12:00:00 AM		Permit Finaled	07/03/2019 12:00:00 AM	ADDRESS	34.0644	-118.48186	pv1install roof mounted pv system sized  8.8KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76701	19041-10000-13772	12001 W SUNSET BLVD	90049	11	132B141    49	4402011017	RE15-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	Commercial			04/16/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	10/28/2021 12:00:00 AM	ADDRESS	34.06128	-118.47512	Full PC (Pwr and Energy) for New 2 story private  Elementry school over 1 level subterranean parking. Existing service 800A,480/277V,4wire,3phase. Scope of work is 30,873SF.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76702	10041-20001-16462	4970 E HUNTINGTON DR SOU	90032	14	144A235   330	5218009040	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	LA-32	YES	2015.03	Electrical	Electrical	Commercial			09/20/2010 12:00:00 AM			PC Approved	09/20/2010 12:00:00 AM	PIN	34.08743926	-118.17418947	PLAN CHECK ONLY. PLAN CHECK T-24 ENERGY (GENERAL/EMERGENCY) LIGHTING FOR INDOOR AND OUTDOOR. EXISTING PERMIT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76703	13041-10000-24162	521 W 7TH ST GRND FLOOR	90014	14	129A209   136	5144003906	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			PC Approved	09/05/2013 12:00:00 AM	ADDRESS	34.04714	-118.25608	TI of (E) restaurant.  Title 24 plan check only for new lighting system.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76704	13041-10000-06853	1302 W 177TH ST BLDG B	90248	15	063B197    93	6111025904	[Q]PF-1XL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Apartment			03/20/2013 12:00:00 AM	11/04/2013 12:00:00 AM		Permit Finaled	11/26/2014 12:00:00 AM	ADDRESS	33.86988	-118.29684	PLAN CHECK FOR POWER AND ENERGY FOR A NEW THREE STORY 33-UNIT APARTMENT BUILDING (BUILDING B). MODIFICATION TO SEPARATE FIRE ALARM SYSTEM HAS BEEN FILED	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76705	16041-20002-34075	9601 N CANOGA AVE	91311	12	201B105   248	2746015***	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	Commercial			04/21/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	10/02/2017 12:00:00 AM	ADDRESS	34.24501	-118.59876	Revisions to approved set.  Additional motor assembly loads, deletion of panel.  Delta-D revisions only.  Plan check for power.  Affected sheets: E-003, E-101, E-602. (((TI to an existing single-story commercial building/food production facility.  Addition of new equipment to existing service boards.  Newly connectd load >400 amps - plan check for power and energy.  Total square feet:  17296 sq ft.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76706	15041-20000-20629	3521 N LIFUR AVE	90032	14	142-5A237  34	5219017033	R2-1	East Los Angeles	Northeast Los Angeles	LA-32		2015.01	Electrical	Electrical	1 or 2 Family Dwelling			06/30/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	02/29/2016 12:00:00 AM	ADDRESS	34.08662	-118.16776	Installation of new roof mounted solar PV system.  Total system size = 4 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76707	14041-20001-33690	21501 W VENTURA BLVD	91367	3	171B105     7	2168027031	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			03/03/2015 12:00:00 AM	03/03/2015 12:00:00 AM		Permit Finaled	04/06/2016 12:00:00 AM	PIN	34.16881252	-118.59888323	CHANGE TO LIGHITNG DESIGN. ONLY CHANGE SWITCH FROM 2X4 TO LED DOWNLIGHTS. CHANGES CLOUDED DELTA 1. NEW CALCS HAVE BEEN PROVIDED. T24 ONLY. PERMIT ISSUED FOR 2 ADDITIONAL SMOKE DETECTORS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76708	18041-10001-23894	360 E 2ND ST 7TH FLR	90012	14	129A215   135	5161020028	[Q]C2-4D-O-CDO	Central	Central City	Los Angeles Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM			PC Info Complete	09/27/2018 12:00:00 AM	ADDRESS	34.04805	-118.24012	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 8. CHANGES INCLUDE ADDING REPLACING LIGHTING FIXTURES, RELOCATING/ADDING EXIT SIGNS, ADDING RECEPTACLES, AND  REVISING TITLE 24 CALCULATIONS. B#18016-10000-18669	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76709	11041-20000-01815	1830 S WESTERN AVE	90006	10	126B193   827	5074015045	[Q]C2-1-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2213.02	Electrical	Electrical	Commercial			01/31/2011 12:00:00 AM	04/11/2011 12:00:00 AM		Permit Finaled	09/06/2011 12:00:00 AM	ADDRESS	34.04077	-118.30873	PLAN CHECK POWER AND OUTDOOR ENERGY FOR CAR WASH MIXED USED BUILDING. NEW 1200A SERVICE AND SERVICE EQUIPMENT. TENANT LOADS ARE FUTURE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76710	12041-10000-00397	5541 N LAUREL CANYON BLVD	91607	2	174B165   809	2347015024	R3-1, [Q]C1.5-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.02	Electrical	Electrical	Apartment			01/06/2012 12:00:00 AM	08/28/2012 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	ADDRESS	34.17135	-118.3967	Plan check 39.840KW roof mounted photovoltaic system for apartment building	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76711	18041-20001-42121	9868 N SUNLAND BLVD	91040	7	201B181   152	2545014006	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2018 12:00:00 AM	12/20/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	34.24889	-118.34724	12/05/2018 Changes to an approved set of plans. Work description shall now read as follows:Plan check for a PV1 roof-mounted PV system. System size is 16.5 kWdc/14.025 kWac-CEC and consists of (1) 11.4 kWac rated inverter and (55) modules.*****Previous Work Description*****Plan check for PV roof mounted system, system size: 16.5kW DC, 17.6KW AC with 55 PV Modules and 2 inverters(7.6kW and 10.0kW)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76712	18041-10000-04154	1030 E VERNON AVE	90291	11	111B145   189	4243027010	R1V2	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	1 or 2 Family Dwelling			02/05/2018 12:00:00 AM	02/05/2018 12:00:00 AM		Permit Finaled	03/27/2018 12:00:00 AM	ADDRESS	34.00343	-118.46226	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.825KWdc / 9.0KWac. (21) MODULES-SOLARCITY SC325(1)INVERTER-SOLIVIA 3.8 TL(1)INVERTER-SOLIVIA 5.2 TL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76713	18041-10000-15977	7213 N RESEDA BLVD	91335	3	183B125   127	2118029001	[Q]C2-2D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1310.20	Electrical	Electrical	Commercial			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Issued	05/01/2018 12:00:00 AM	ADDRESS	34.20158	-118.53625	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76714	15041-20000-03067	12491 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	08/25/2015 12:00:00 AM	ADDRESS	33.97895	-118.41081	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76715	18041-10000-17407	10857 N SAN FERNANDO ROAD	91331	7	207B157   158	2619016071	[Q]C2-1-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1044.04	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	06/19/2018 12:00:00 AM	ADDRESS	34.26714	-118.42359	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76716	14041-10001-14945	2466 N HIDALGO AVE	90039	13	148-5A209 199	5440014028	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2014 12:00:00 AM			PC Approved	07/01/2014 12:00:00 AM	ADDRESS	34.10194	-118.25625	PV1, INSTALL 9.18 KW DC ROOF-MOUNTED SOLAR ARRAY ON A ONE-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76717	15041-20000-16800	6256 N TOPANGA CANYON BLVD C-1340	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/02/2015 12:00:00 AM	08/03/2015 12:00:00 AM		Permit Finaled	11/10/2015 12:00:00 AM	ADDRESS	34.18496	-118.6049	TI to existing commercial building (T-mobile). First time tenant. Plan check for power and energy. Adding new lighting includng emergency. Total sqft. 2834	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76718	14041-10000-04089	1800 W BEVERLY BLVD	90057	13	135A205   319	5154001019	C2-1, R4-1	Central	Westlake	Westlake North		2084.01	Electrical	Electrical	Commercial			02/13/2014 12:00:00 AM			PC Approved	11/04/2014 12:00:00 AM	ADDRESS	34.06495	-118.26724	"PC FOR POWER ONLY. SERVICE UPGRADE. NO TENANT PANELS TO BE INSTALLED. no building application started.""COMPLY WITH DEPARTMENT ORDER effective date03/11/2010. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""INVESTIGATION FEES DUE - work without permit for:BUILDING A NEW PARPIT FACAD WITHOUT BUILDING PERMIT- STOP ALLUNPERMITED WORK IMEADIATLYORDER TO COMPLY ISSUED:  09/22/2011(Created: 310180 / 09-22-11)"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76719	16041-10000-45457	812 S MAIN ST	90291	11	109-5A143 574	4286012035	C2-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	12/08/2022 12:00:00 AM		Issued	12/08/2022 12:00:00 AM	ADDRESS	33.99258	-118.47418	PC FOR POWER AND ENERGY (N) 3-STORY 43-GUEST ROOM HOTEL, 5-UNIT CONDO & 2-RETAIL TENANT SPACES W/ 2-LEVEL SUBTERRANEAN PKG GARAGES MIXED USE BLDGSERVICE RATED AT 2500A 120/208Total area: 79,512 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76720	14041-10000-22919	5924 S SAN PEDRO ST	90003	9	105B205   210	6006029026	[Q]MR1-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2014 12:00:00 AM	10/10/2014 12:00:00 AM		Permit Finaled	11/14/2014 12:00:00 AM	ADDRESS	33.98677	-118.26941	PV1, INSTALL 3.06 KW DC ROOF-MOUNTED SOALR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(12) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76721	16041-20000-10517	19524 W NORDHOFF ST #11	91324	12	195B117    10	2783028048	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			03/25/2016 12:00:00 AM			PC Approved	03/25/2016 12:00:00 AM	ADDRESS	34.23527	-118.55871	Plan check for energy only. Change of use from restaurant to music studio. New lighting (incl. emergency). 4,515sqft. Electrical permit pulled under permit #16041-20000-05567	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76722	14041-10000-32362	6320 N TOPANGA CANYON BLVD Building G	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			11/20/2014 12:00:00 AM			Reviewed by Supervisor	12/26/2014 12:00:00 AM	ADDRESS	34.18578	-118.60536	Power plan check for new electrical equipment related to outdoor lighting systems for common area of Westfield Topanga outdoor mall.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76723	19041-10000-35058	5909 N MELVIN AVE	91356	3	177B117   765	2153024008	RA-1	South Valley	Encino - Tarzana	Tarzana		1393.01	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Permit Finaled	02/12/2020 12:00:00 AM	ADDRESS	34.17782	-118.56023	Permit fee is $0.00 due to Assembly Bill 1414.[EPLAN]PLAN CHECK FOR ROOF MOUTED 13KVA PV1 SYSTEM CONSISTING OF 2 INVERTERS(SE10000H-US, SE3000H-US) WITH 41 MODULES USING P370 OPTIMIZERS CONNECTED TO NEW SERVICE NEW 200A SERVICE UNDER SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76724	17041-10000-41521	10250 W SANTA MONICA BLVD #9196-&9198	90067	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			11/16/2017 12:00:00 AM	04/03/2018 12:00:00 AM		Permit Finaled	05/24/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	FULL PLAN CHECK (POWER+ENERGY) FIRST TIME TENANT SPACE  (UNIT# 9196, 9198), ADDING (1) PANEL FOR EACH TENANT TO (E) LANDLORD'S DIST BOARD, TOTAL AREA FOR #9196 IS 455SQ.FT, AND FOR #9198 IS 450SQ.FT(B# 13016-10036-16108)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76725	15041-20000-43997	201 N FIGUEROA ST 14th Floor	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM	01/06/2016 12:00:00 AM		Permit Finaled	01/22/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	Plan check for Title 24 only. Project site is an existing commercial, high-rise building. Project scope is a tenant improvement to the 14th floor. Total lighting area =  390 sq. ft.Note: Building permit has been pulled under 15016-10000-18047	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76726	13041-20001-05364	6605 N FALLBROOK AVE	91307	12	180B097   311	2038040015	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1352.01	Electrical	Electrical	Commercial			05/29/2013 12:00:00 AM			Corrections Issued	05/29/2013 12:00:00 AM	ADDRESS	34.18874	-118.62363	((((5/29/2013: CHANGES MADE TO APPROVED SET OF PLANS. CHANGES MADE TO OUTDOOR LIGHTING AND ALTERED PANELS 'A' AND 'B' ))))Install new 600 ampere distribution boards to supply remodeled tenant space of existing building.  Plan check for power, T-24 and emergency lighting plan check.  The new switch board is supplied from an existing distribution board in the existing sprouts receiving area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76727	19041-20000-38687	5731 W LEXINGTON AVE	90038	13	144B189   277	5536005006	R3-1	Central	Hollywood	Hollywood Studio District		1909.01	Electrical	Electrical	Apartment			09/25/2019 12:00:00 AM	09/25/2019 12:00:00 AM		Permit Finaled	11/25/2020 12:00:00 AM	ADDRESS	34.09288	-118.31469	INSTALL (47) NEW FIRE ALARM DEVICE AND (1) PANEL FOR AN APARTMENT BUILDING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76728	13041-10000-26049	20247 W VIA SANSOVINO	91326	12	219B113   315	2701062030	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			09/20/2013 12:00:00 AM	12/19/2013 12:00:00 AM		Permit Finaled	12/30/2013 12:00:00 AM	ADDRESS	34.29758	-118.57419	PV1 ROOF-MOUNTED SOLAR ARRAY INSTALLATION, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZE IS 10.5KW DC IN A 2-STORY HOME. (42) MODULES: TRINA TSM-250PA05(1)INVERTER: FRONIUS V 10.0	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76729	14041-20000-15265	15821 W VENTURA BLVD suite 300	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			06/09/2014 12:00:00 AM	06/09/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.15584	-118.47812	TI in existing commercial office space in lowrise commercial building.  Source of emergency power to be (E) on-site generator.  Plan check for Title 24 Part 6 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76730	12041-10000-06164	12035 W OSBORNE ST	91331	7	210B165   543	2532017066	(T)(Q)C2-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Pacoima		1041.06	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	05/31/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.27301	-118.39494	PLAN CHECK 2 STORY APARTMENT BUILDING. BLDG #5. 600A SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76731	10041-20000-02207	2840 E OLYMPIC BLVD	90023	14	120A221   123	5170026010	M1-1	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			02/08/2010 12:00:00 AM	06/30/2010 12:00:00 AM		Permit Finaled	11/15/2010 12:00:00 AM	ADDRESS	34.02265	-118.21652	REMODEL FIRE DAMAGE BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76732	19041-10000-33856	12224 W DARLINGTON AVE	90049	11	129B145   975	4264023022	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/10/2019 12:00:00 AM		Permit Finaled	06/15/2020 12:00:00 AM	ADDRESS	34.04645	-118.47154	[EPLAN] PLAN CHECK FOR 2 ESS(TESLA POWERWALL) TO EXISTING PV SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76733	19041-20001-44799	3772 E SAN RAFAEL AVE	90065	1	148-5A221 129	5464015011	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1852.02	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM			PC Approved	12/11/2019 12:00:00 AM	ADDRESS	34.10048	-118.21876	12-11-2019 Changes to an approved set of plan, changes include remove performance meter. All changes has been clouded.Plan check only, permit covered under master application. Fees $0.00 due to California Senate Bill 1222 and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76734	17041-20002-31426	3930 S WISCONSIN PL	90037	8	117B197   954	5037019007	RD1.5-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	1 or 2 Family Dwelling			10/31/2017 12:00:00 AM			PC Approved	10/31/2017 12:00:00 AM	ADDRESS	34.01453	-118.29323	10/31/2017 CHANGES TO APPROVED SET. CHANGES HAVE BEEN CLOUDED. CHANGING THE MAIN SERVICE PANEL TO 200 AMPS. *****Previous Work Description*****PC FOR ROOF MOUNTED PV SYSTEM ON SFD. SYSTEM SIZE 3.36 KW AC  4.06 KW DCSCOPE INCLUDES 14 MODULES WITH 14 MICRO INVERTERS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76735	16041-10000-31728	4729 W VENICE BLVD	90019	10	129B181   946	5070013003	C2-1-O	Central	Wilshire	Mid City		2172.00	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	11/29/2016 12:00:00 AM	ADDRESS	34.04692	-118.34001	T-24, PC FOR ENERGY ONLY. TI TO (E) RESTAURANT. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 1040 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76736	19041-10000-11432	1019 E 4TH PL 5TH FLR	90013	14	127-5A217  60	5163018006	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM	05/20/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.04195	-118.23327	PC FOR TI OF AN EXISTING 5 STORY OFFICE BLDG.TOTAL CONNECTED LOAD >400AFULL FLOOR BUILD OUT (5TH FLR)SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT, PANELS AND LIGHTS. TOTAL AFFECTED AREA 10600.NEW 2019 T24B#19016-10000-08847	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76737	18041-10000-11060	3020 E WASHINGTON BLVD	90023	14	117A221    64	5169025***	M3-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2051.20	Electrical	Electrical	Commercial			03/27/2018 12:00:00 AM	05/09/2018 12:00:00 AM		Permit Finaled	09/28/2018 12:00:00 AM	ADDRESS	34.01664	-118.21526	FULL PC, TENANT IMPROVEMENT TO EXISTING WAREHOUSE FACILITY INCLUDING OFFICES, EMPLOYEE AREAS, AND RESTROOMS. SCOPE OF WORK INCLUDES EXISTING 3000AMP SERVICE AND NEW 800 AMP DISTRIBUTION BOARD. TOTAL SQ. FT. 33000.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76738	12041-10000-05306	1011 S ARLINGTON AVE	90019	10	129B189   292	5081018026	C2-1-O	Central	Wilshire	Olympic Park		2127.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM	05/23/2012 12:00:00 AM		Permit Finaled	09/19/2012 12:00:00 AM	ADDRESS	34.05218	-118.31571	Change of use from retail to dental offices. two story bldg, unit ground level, title 24 energy, power and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76739	16041-20000-41809	1216 W 8TH ST	90017	1	130-5A205 366	5143002010	CW	Central	Westlake	Westlake South		2093.00	Electrical	Electrical	1 or 2 Family Dwelling			11/29/2016 12:00:00 AM	11/29/2016 12:00:00 AM		Permit Closed	01/11/2017 12:00:00 AM	ADDRESS	34.04977	-118.2684	Plan check for a PV1 roof-mounted PV system. System size is 1 kWac and consist of (4) micro-inverters and (4) modules. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76740	13041-10001-33143	4437 N SIMPSON AVE	91607	2	165B169   148	2364010018	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1433.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM			PC Approved	12/08/2013 12:00:00 AM	ADDRESS	34.15143	-118.38901	Expedited plan check per applicant request.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76741	16041-20000-00130	756 E WASHINGTON BLVD	90011	9	121-5A209 200	5131006012	M1-2-O	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			01/04/2016 12:00:00 AM			PC Approved	01/04/2016 12:00:00 AM	PIN	34.02658652	-118.25584821	TI to existing commercial building (Sewing, clothing manufactoring). Plan check for energy only. Adding new lighting including emergency. Total sqft. 5,300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76742	16041-20000-10251	5136 N MOUNT HELENA AVE	90041	14	163-5A227 344	5691004028	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1810.00	Electrical	Electrical	1 or 2 Family Dwelling			03/23/2016 12:00:00 AM	03/23/2016 12:00:00 AM		Permit Finaled	05/21/2016 12:00:00 AM	ADDRESS	34.14057	-118.19569	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 7.6kW (3.8+3.8). Ungrounded system. (32) 255W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76743	17041-10000-16183	238 S MANHATTAN PL	90004	4	135B193    73	5517001028	R3-1	Central	Wilshire	Greater Wilshire		2115.00	Electrical	Electrical	Commercial			05/15/2017 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/03/2017 12:00:00 AM	ADDRESS	34.06993	-118.31018	T24 ONLY, REPLACE (E) LIGHT FIXTUES WITH (N) LED LIGHT FIXTURES. TOTAL AREA  68225 SQ FT. OUTDOOR	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76744	19041-10000-29599	6051 W MELROSE AVE	90038	4	141B185   584	5533036012	C4-1XL	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			07/31/2019 12:00:00 AM			PC Info Complete	07/31/2019 12:00:00 AM	ADDRESS	34.08357	-118.33224	PERMIT FEES PAIF FOR UNDER 20041-70000-10559PC for T24 only for a chnage of use from retail to coffee shop. Scope of work includes new lighting, receptacles, and controls. Total affected area is 1197 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76745	18041-20001-17751	11805 W GWYNNE LANE	90077	5	153B141   103	4378037075	(Q)RD6-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2018 12:00:00 AM	11/01/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.11583	-118.47417	11-01-2018 Changes to an apporved set of plan. Changes include addition on 2 Tesla Power Wall 2.0. Energy Storage Device system size: 27kWh.  All changes has been clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76746	17041-10001-07409	20221 S HAMILTON AVE	90502	15	054B197    33	7351033022	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM			PC Approved	08/23/2017 12:00:00 AM	ADDRESS	33.84695	-118.28626	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 2 ON PLANS. REVISED FLOOR PLANS TO SHOW DAYLIGHT AREAS AND SAID REQUIRED CONTROLS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76747	18041-20000-48136	1425 N SAN PABLO ST b103c-b103d	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			12/19/2018 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	08/22/2019 12:00:00 AM	ADDRESS	34.06176	-118.20365	ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76748	14041-20001-02626	11120 W HUSTON ST 1-34	91601	2	168B173   208	2353020031	R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			09/29/2014 12:00:00 AM			PC Approved	09/29/2014 12:00:00 AM	ADDRESS	34.15954	-118.37245	"Plan check only. Changes to approved set, including: moving location of service equipment, changing fully rated breakers to series rated breakers for unit panels. Delta ""A"" changes.[[[New 4-story, low rise residential building with 34 unit apartment.  New 1200A service.  Plan check for power and energy.  Note: Fire alarm variance has been filed.]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76749	13041-20000-27933	10250 W CONSTELLATION BLVD 1st Floor	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			10/08/2013 12:00:00 AM	10/22/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.05735	-118.41746	PLAN CHECK FOR POWER AND ENERGY FOR EXISTING CAFE. SCOPE OF WORK ON THE FIRST FLOOR	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76750	15041-20000-09662	1075 W CHILDS WAY	90089	9	120B197   677	5039002031	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			04/08/2015 12:00:00 AM	06/17/2015 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.02304	-118.29105	PLANCHECK FOR POWER AND ENERGY.   TENANT IMPROVEMENT FOR MARKS TENNIS STADIUM IN USC. 9750 SQFT INDOOR AND 5500 SQFT OUTDOOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76751	14041-10000-15078	5757 W WILSHIRE BLVD	90036	4	135B177   470	5508015007	QPB-2, [Q]C4-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			06/06/2014 12:00:00 AM			PC Approved	06/06/2014 12:00:00 AM	ADDRESS	34.06259	-118.35341	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICE. GROUND FLOOR.  8934 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76752	15041-20000-22278	7416 N BELLINGHAM AVE	91605	2	186B165   508	2307025046	(Q)RZ3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Expired	08/08/2017 12:00:00 AM	ADDRESS	34.20531	-118.39872	Plan check for a PV1 roof-mounted PV system. System size is 5 kWac and consists of (1) inverter, (24) modules, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76753	13041-10000-18467	14161 W DELANO ST #1-10	91401	6	177B153   418	2240019027	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Apartment			07/12/2013 12:00:00 AM	07/12/2013 12:00:00 AM		Permit Finaled	03/19/2014 12:00:00 AM	ADDRESS	34.18276	-118.44206	NEW FIRE ALARM INSTALLATION WITH 23 DEVICES, 1 PANEL, IN A NEW 3-STORY APARTMENT, 10 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76754	18041-30001-14375	2002 S SAWTELLE BLVD	90025	11	126B153   676	4261032054	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			04/30/2019 12:00:00 AM			PC Approved	04/30/2019 12:00:00 AM	ADDRESS	34.04089	-118.44337	04/30/2019 Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 728 sq. ft.*****Original Work Description*****NEW LOCATIONS FOR OUTLET, LIGHTS AND SWITCHES FOR TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76755	14041-20001-10887	20706 W ARCHWOOD ST	91306	3	180B109   259	2148021013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1349.04	Electrical	Electrical	1 or 2 Family Dwelling			04/24/2014 12:00:00 AM			PC Approved	05/06/2014 12:00:00 AM	ADDRESS	34.19155	-118.58416	Fee for expedite*****Roof mounted PV system with optimizer, system size 3.5KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76756	16041-10001-29143	660 S FIGUEROA ST	90017	14	129A209    19	5144008013	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	34.04953	-118.25947	Supplemental PC for changes to emergency lighting. Connecting emergencylights to emegency panel. All changes clouded under delta 8.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76757	17041-20000-25196	515 S FIGUEROA ST ste 1235	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/25/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	ti to an existing commercial building high rise.  adding new lighting new controls to existing panels.  plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76758	18041-10000-44972	19191 S VERMONT AVE STE 130	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	02/22/2019 12:00:00 AM	ADDRESS	33.85656	-118.29099	T-24 only check for office tenent improvment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76759	13041-20000-09129	13314 N FREDERICK WY	91342	7	225B157  1032		(T)(Q)RD1.5-1VL	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			04/09/2013 12:00:00 AM	04/09/2013 12:00:00 AM		Permit Finaled	05/15/2013 12:00:00 AM	PIN	34.31253789	-118.42511113	Enphase system on roof of single family dwelling..	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76760	15041-10001-28050	736 S LA BREA AVE	90036	4	132B181  1300	5507024019	[Q]C4-2D, [Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			08/17/2016 12:00:00 AM			PC Approved	08/17/2016 12:00:00 AM	ADDRESS	34.06115	-118.3442	"08/17/17Changes to an approved set of plans. All changes are clouded under delta 1. Changes to reflect what is on field such as the existing AIC rating of the existing 600A switchboard, revisions to fault currents at panels ""PA"", ""FC"", and panel ""HP"", and revisions to lighting plans. ((((CHANGE OF USE FROM RETAIL TO RESTAURANT"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76761	19041-10000-12693	8018 W 3RD ST	90048	5	138B177   762	5511028027	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			04/08/2019 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	34.07179	-118.36448	Energy plan check for a change of use from restaurant to a a retail. Scope includes new lighting and equipment with a total area of 776-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76762	11041-10000-14625	10700 W SANTA MONICA BLVD STE 140	90025	5	129B157   356	4321004020	C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2671.00	Electrical	Electrical	Commercial			07/14/2011 12:00:00 AM			PC Approved	07/18/2011 12:00:00 AM	ADDRESS	34.05167	-118.432	TI TO AN EXISTING OFFICE SPACE.  PLAN CHECK IS FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76763	14041-20000-17263	811 W 7TH ST #800	90017	14	129A209    39	5144008008	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/26/2014 12:00:00 AM	07/02/2014 12:00:00 AM		Permit Finaled	08/06/2014 12:00:00 AM	ADDRESS	34.04908	-118.25911	T.I. to existing high rise building on the 8th floor.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76764	16041-20000-20399	8207 W 3RD ST #A	90048	5	138B173   832	5511019025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/09/2016 12:00:00 AM	06/09/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.07262	-118.36835	"CONVERT 12'-5""X21'-10"" (275SF) PORTION OF (E) RETAIL TO (N) BEAUTY SALON AND & INTERIOR REMODEL.  PLAN CHECK FOR ENERGY - 255 SQ FT."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76765	16041-20001-44257	5331 N CORBIN AVE	91356	3	171B117   114	2164002036	RA-1	South Valley	Encino - Tarzana	Woodland Hills - Warner Center		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.16748	-118.56288	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 15.2 kWac and consists of (2) inverters, (61) modules, (1) load center, and (2) combiner boxes.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76766	18041-10000-24873	841 S LA PALOMA AVE	90744	15	024B205    22	7440014904	M3, [Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			07/11/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	01/23/2019 12:00:00 AM	ADDRESS	33.76076	-118.26497	Plan check for Power only for hazardous area classification. Installing new Diesel Pump, Cargo Pump, Vapor Combustion Units, etc.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76767	09041-10003-24226	13488 W MAXELLA AVE	90292	11	105B153    77	4212004014	[Q]M1-1, [T][Q]RAS4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	01/21/2011 12:00:00 AM		Permit Finaled	04/19/2013 12:00:00 AM	ADDRESS	33.98592	-118.44252	New 244 apartment building in methane zone.  Variance was filed to separate the the Fire Alarm plans and approval.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76768	16041-10000-31753	12366 W COHASSET ST	91605	2	186B165   261	2307024***	[Q]R3-1	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.01	Electrical	Electrical	1 or 2 Family Dwelling			09/07/2016 12:00:00 AM	09/07/2016 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.2066	-118.40301	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.8KWac.(14)MODULES-Q-CELLS Q.PRO-G4 265(1)INVERTER-SMA SB3800TL-US-22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76769	17041-10000-10240	1351 W 244TH ST	90710	15	039B197   100	7439019021	R1-1XL-O	Harbor	Wilmington - Harbor City	Harbor City		2933.02	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/13/2017 12:00:00 AM	ADDRESS	33.80252	-118.30017	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 6.20KWdc / 5.0KWac.(20)MODULES-LG NEON2 LG 310N1C-G4(20)MICROINVERTERS-ENPHASE M250-60-2LL-S2X	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76770	19041-10000-08751	10101 S BROADWAY	90003	8	091-5A203 235	6053024019	C2-1VL	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			03/12/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	05/08/2019 12:00:00 AM	ADDRESS	33.94445	-118.27854	PV2. NEW SOLAR SYSTEM ON EXISTING COMMERCIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 30.24KWdc / 28.8KWac.(84)MODULES-JINKO SOLAR JKM360M-72V(2)INVERTER- SOLAREDGE SE14.4KUS(24)OPTIMIZERS-SOLAREDGE P730(18)OPTIMIZERS-SOLAREDGE P850	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76771	12041-20002-29785	9711 N WHEATLAND AVE	91040	7	201B177   348	2544008014	RE40-1-K	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2013 12:00:00 AM			PC Approved	05/08/2013 12:00:00 AM	ADDRESS	34.2458	-118.35761	[THIS IS A PLAN CHECK ONLY. CHANGES MADE TO APPROVED SET OF PLANS. CHANGED CONDUIT TYPE]20.02kW DC System.Lost set of plans.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76772	18041-10000-44449	9880 N SAN FERNANDO ROAD	91331	7	201B165    51	2537014009	M1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1047.03	Electrical	Electrical	Commercial			11/20/2018 12:00:00 AM	11/21/2018 12:00:00 AM		Permit Finaled	04/09/2019 12:00:00 AM	ADDRESS	34.25015	-118.40435	REMOVE INDOOR/OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76773	10041-10002-25103	13275 N GOLDEN STATE RD	91342	7	225B141  1516	2604002059	(Q)M1-1VL	North Valley	Sylmar	Sylmar		1066.04	Electrical	Electrical	Commercial			12/23/2011 12:00:00 AM	12/23/2011 12:00:00 AM		Permit Finaled	12/29/2011 12:00:00 AM	PIN	34.31226914	-118.48573073	Install equipment and wiring for fuel  management system FMS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76774	13041-10000-20535	5337 S ARLINGTON AVE	90043	8	108B189   463	5005004023	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2346.00	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2013 12:00:00 AM	08/01/2013 12:00:00 AM		Permit Finaled	08/20/2013 12:00:00 AM	ADDRESS	33.99404	-118.31832	PV1 2.376 KW 240V MICROINV 1STORY. STD. ROOFMOUNT.[( 11) MICROINVERTER: ENPHASE ENERGY M215-60-2LL-S22] [MODULE: yingli {YL245P-29b}]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76775	10041-10000-05822	2029 S CENTURY PARK EAST 21st	90067	5	132B161   697	4319016029	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM			PC Approved	03/31/2010 12:00:00 AM	ADDRESS	34.05956	-118.41375	T.I. @ 21ST floor, Energy only plan check.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76776	14041-10000-25847	12655 W BEATRICE ST	90066	11	105B157   658	4211006017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			09/19/2014 12:00:00 AM	09/19/2014 12:00:00 AM		Issued	09/19/2014 12:00:00 AM	ADDRESS	33.98007	-118.41764	installing , printing equipment,  sevice existing.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76777	16041-10001-04906	966 N MORAGA DR	90049	5	141B145   234	4368019015	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	34.08188	-118.46728	EXPEDITE FEEPV1, rooftop solar installation 14kW system. Interconnect with 600A MS.(48) SPR-327NE-WHT-D(2) SMA 7000US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76778	17041-10001-03201	1942 S POINT VIEW ST	90034	10	126B173   749	5066016025	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.04073	-118.37336	CHANGES TO APPROVED SET OF PLANS. CHANGES INCLUDE ADDITION OF MODULES TO SCOPE OF WORK. TOTAL NUMBER MODULES NOW 29 AND STILL USING 6KW INVERTER.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76779	15041-20001-05340	6316 N TOPANGA CANYON BLVD SUITE 1110	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM			PC Approved	06/19/2015 12:00:00 AM	ADDRESS	34.18578	-118.60514	"06-19-2015 Change to approved set of plans. Changes include split approved panel ""P1"" into 2 sections , incorporate additional ornamental lights into controls and  title 24 calculation. [[[[[PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. XOC TEQUILA GRILL. WESTFIELD TOPANGA MALL. SUITE 1110]]]]"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76780	15041-20000-12527	13574 W D'ESTE DR	90272	11	132B133   193	4425031009	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades			2624.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2015 12:00:00 AM	06/26/2015 12:00:00 AM		Issued	06/26/2015 12:00:00 AM	ADDRESS	34.05743	-118.50077	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Single inverter system with 400 A main.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76781	15041-10001-13242	200 WORLD WAY SPACE 1520	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/26/2015 12:00:00 AM			PC Approved	06/26/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	Revisions to approved set.  Quantity and type of lighting fixtures changed.  Other power revisions not in scope of plan check.  Delta 3 changes only.  ((Relocation of existing 6 kVA transformer and panel to serve new lighting and walk-in cooler.  Plan check for energy.))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76782	17041-30000-36194	3283 S MOTOR AVE	90034	5	123B161   995	4314022041	C2-1	West Los Angeles	West Los Angeles			2699.04	Electrical	Electrical	Commercial			10/10/2017 12:00:00 AM			Re-Activate Permit	01/25/2018 12:00:00 AM	ADDRESS	34.0293	-118.41102	Plan check for Title 24 only in existing space T.I. replace lighting and receptacles. Total area: 2342 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76783	15041-10001-38580	21525 W DEVONSHIRE ST	91311	12	204B105   860	2722007052	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM			PC Approved	04/13/2016 12:00:00 AM	ADDRESS	34.2574	-118.59907	SUPPLEMENTAL TO APPROVE D SET OF PLAN, REPLACING EXSITING FIXTURES WITH NEW HID LIGHT FIXTURES.  TOTAL AREA 4671 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76784	15041-10000-13845	800 E D ST	90744	15	030B209   960	7424016030	[Q]M2-1VL-O	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Expired	06/01/2017 12:00:00 AM	ADDRESS	33.77456	-118.25259	T24. REPLAC EXISTING LIGHT FIXTURES WITH LED. TOTAL AREA 11834 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76785	12041-10002-10012	15604 W ROYAL WOODS PL	91403	5	162B141   237	2280005011	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM			PC Approved	08/31/2012 12:00:00 AM	ADDRESS	34.14044	-118.47257	Revision to approved plans from. Reduce system size from 11.445KW to 9.156KW, change inverter, and remove one string, total of 28 modules.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76786	10041-30000-07886	12312 W OLYMPIC BLVD 1ST FLOOR	90064	11	123B149   659	4259025008	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			04/29/2010 12:00:00 AM	06/15/2010 12:00:00 AM		Permit Finaled	08/11/2010 12:00:00 AM	ADDRESS	34.03166	-118.45665	TENANT IMPROVEMENT IN OFFICE  AREA. THIS PLAN CHECK IS FOR TITLE 24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76787	18041-10000-46956	663 N RADCLIFFE AVE	90272	11	126B125   384	4412014038	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.06	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	04/04/2019 12:00:00 AM	ADDRESS	34.04279	-118.5308	PC FOR NEW 27KW ENERGY STORAGE SYSTEM, SCOPE INCLUDES (2) 14KW BATTERIES (TESLA POWER WALL) AND (1) 200A LOAD CENTER DISTRIBUTION PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76788	18041-20001-08945	539 S MAPLETON DR	90024	5	138B157    57	4359013038	RE40-1	West Los Angeles	Westwood	Bel Air - Beverly Crest, Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			03/12/2018 12:00:00 AM			PC Approved	03/17/2018 12:00:00 AM	ADDRESS	34.07466	-118.42924	expeditepv1install roof mounted pv system sized 19kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76789	12041-20003-03869	8120 N WOODMAN AVE	91402	6	192B157   814	2213020024	R1-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1204.00	Electrical	Electrical	Commercial			12/26/2013 12:00:00 AM			PC Approved	12/27/2013 12:00:00 AM	ADDRESS	34.21871	-118.43098	((Changes made to approved set of plans. No new equipment added, verifying notation))New medical office bldg.  Variance to separte the fire waring system from the electrical system was submitted on october 22, 2012.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76790	19041-20000-53244	11677 W SHELDON ST	91352	6	201B169   117	2537023008	M2-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley Area		1211.02	Electrical	Electrical	Commercial			12/24/2019 12:00:00 AM			Reviewed by Supervisor	02/06/2020 12:00:00 AM	ADDRESS	34.24433	-118.38716	INSTALL NEW PANELS AND EQUIPMENTS ON EXISTING SERVICE.NOTE PER BUILDING:CHANGE OF USE FROM MACHINE SHOP TO INDOOR NURSERY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76791	14041-10000-31233	909 S SANTA FE AVE	90021	14	123A217   108	5166012010	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			11/10/2014 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.03228	-118.23021	Plan check for power and title 24.  Total area = 5,105 sq. ft. (indoor) and 3,600 sq. ft. (hardscape)T.I. to a restaraunt space (change of occupancy; previously warehouse).  Installation of new panels (625 amps), recepticles, and lighting.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76792	13041-20000-33190	8020 W MELROSE AVE	90048	5	141B177   617	5527015005	C4-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	07/11/2014 12:00:00 AM		Permit Closed	07/12/2017 12:00:00 AM	PIN	34.08350631	-118.36447698	T24 FOR EXISTING SPACE. USE OF BUILDING HAS NOT CHANGED. TOTAL NEW CONNECTED LOAD DOES NOT EXCEED 400A. 3500 SQRFT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76793	17041-10000-05600	9000 W VENICE BLVD 9008, 9012-9014	90034	5	120B169   173	4206032046	M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2701.00	Electrical	Electrical	Commercial			02/21/2017 12:00:00 AM	04/26/2017 12:00:00 AM		Permit Finaled	07/07/2017 12:00:00 AM	ADDRESS	34.02703	-118.39174	PC FOR T24 ENERGY ONLY. REPAIR OF FIRE DAMAGE BUILDING. CORE AND SHELL SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76794	13041-20000-21364	8900 N DE SOTO AVE	91304	3	195B109    11	2780001026	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	Commercial			08/08/2013 12:00:00 AM	09/03/2013 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.23162	-118.58832	ADDITION OF TRANSFORMER AND SUBPANEL. PER APPLICANT REQUEST, FULL PC. NO ENERGY. POWER SYSTEM ONLY. PC FOR NEW LOAD ON EXISTING 600A BUS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76795	13041-10001-11284	710 N EL CENTRO AVE	90038	13	141B189   274	5534035018	(T)(Q)RAS3-1	Central	Hollywood	Hollywood Studio District		1918.20	Electrical	Electrical	Apartment			02/13/2015 12:00:00 AM			Reviewed by Supervisor	03/24/2015 12:00:00 AM	ADDRESS	34.08386	-118.3243	REVISIONS TO SINGLE LINE DIAGRAM: METER DIST BDS CHANGE FROM MAIN CBS TO FUSIBLR DISCONNECT SWITCHES  AND SHOW LINE -UP AS SHOWN ON ELEVATION DRAWINGpc for power and energy. ~28 typical units. methane buffer zoneNew privately funded 84 unit mixed use project.4 Stories Type VA fully sprinklered R2 occupancy with M Occupancy commercial over 2 levels Type I S2 Occupancy basement parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76796	17041-10002-31743	6569 W DE LONGPRE AVE	90028	13	147A187   258	5547026041	RD1.5-1XL	Central	Hollywood	Central Hollywood		1908.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM	01/05/2018 12:00:00 AM		Permit Expired	09/18/2023 12:00:00 AM	ADDRESS	34.09624	-118.33278	permitted set of plans are revised to include fused disconnects for energy storage systems and non fused disconnect for inverter output circuit.(((((((((((((** NO FINAL FEES DUE TO SENATE BILL 1222PC FOR NEW PV SYSTEM WITH BATTERY STORAGE. SYSTEM INCLUDES 28 MODULES, CENTRAL INVERTER AND 2 BATTERY UNITS RATED 5.8KW EACH. TOTAL OF 27KWH OF STORAGE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76797	16041-30000-01412	18941 W KILFINAN ST	91326	12	219B121    26	2820002006	RS-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.04	Electrical	Electrical	1 or 2 Family Dwelling			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Permit Finaled	02/27/2016 12:00:00 AM	ADDRESS	34.29742	-118.54721	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 5kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76798	15041-10000-38856	8500 N BALBOA BLVD	91325	12	192B133    33	2689019014	M2-1VL, P-1VL	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			11/17/2015 12:00:00 AM	10/26/2016 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.22485	-118.50045	TI TO EXISTING BUILDING. NEW LIGHITNG FOR COMMON AREA IMPROVEMENTS. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76799	13041-20000-28428	3665 S MEIER ST	90066	11	111B153   179	4246016002	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2721.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2013 12:00:00 AM	10/11/2013 12:00:00 AM		Permit Expired	11/05/2015 12:00:00 AM	ADDRESS	34.00357	-118.442	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 2.3 KW AC USING 11MODULES. USING ENPHASE MICROINVERTER STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76800	16041-20000-33641	3045 N VERDUGO ROAD	90065	1	150B213  3602	5457009025	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park		1864.04	Electrical	Electrical	Commercial			09/22/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.10647	-118.23793	Remove existing hid light fixtures and replace with led indoor/outdoor.  plan check for energy only.  total square footage 16800.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76801	13041-20000-07408	1340 S ABBOT KINNEY BLVD	90291	11	108B145  1347	4238004039	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			03/21/2013 12:00:00 AM	03/21/2013 12:00:00 AM		Permit Finaled	07/29/2013 12:00:00 AM	ADDRESS	33.99073	-118.46681	ENERGY PLAN CHECK RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76802	17041-10000-22848	1630 W OLYMPIC BLVD	90015	1	129A203    37	5137016023	C4-1	Central	Westlake			2095.00	Electrical	Electrical	Commercial			07/07/2017 12:00:00 AM	07/07/2017 12:00:00 AM		Permit Finaled	07/19/2017 12:00:00 AM	ADDRESS	34.04945	-118.27525	PLAN CHECK FOR T24 ONLY - SCOPE INCLUDES REPLACE EXISTING FIXTURES WITH LED FIXTURES - TOTAL AFFECTED AREA 21700SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76803	13041-20000-33788	3236 E LANFRANCO ST	90063	14	123A227    92	5186004022	R2-1	East Los Angeles	Boyle Heights	Boyle Heights		2041.20	Electrical	Electrical	1 or 2 Family Dwelling			12/04/2013 12:00:00 AM	12/13/2013 12:00:00 AM		Permit Finaled	12/18/2013 12:00:00 AM	ADDRESS	34.0326	-118.20067	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 4.2 kw ac using 14 modules. transformerless inverter nonstandard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76804	13041-20001-06492	16126 W HARTSOOK ST PV-1	91436	5	171B141   187	2260019006	RE9-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2013 12:00:00 AM	04/04/2013 12:00:00 AM		Permit Finaled	04/11/2013 12:00:00 AM	ADDRESS	34.16376	-118.48459	PV-1. One 6kW inverter. Inverter is equipped with isolation transformer.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76805	16041-20000-23142	3251 W 6TH ST	90020	10	135B197   961	5502023022	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			06/30/2016 12:00:00 AM	07/01/2016 12:00:00 AM		Permit Finaled	08/09/2016 12:00:00 AM	ADDRESS	34.06373	-118.29316	Plan check Title 24 only in existing office space T.I. Total area: 2,101 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76806	13041-10000-19511	8330 N DEMPSEY AVE	91343	12	192B141   407	2673016040	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			07/23/2013 12:00:00 AM	07/26/2013 12:00:00 AM		Permit Finaled	08/07/2013 12:00:00 AM	ADDRESS	34.22234	-118.47752	PV1.  Installing a 6.375 kW roof-mounted solar array, interconnect into main service panel.  {PowerOne PVI-6000-OUTD-US} }{25 modules: Bosch Solar C-SI M60}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76807	16041-10000-00889	7826 S BRIGHTON AVE	90047	8	099B193   598	6018025007	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2378.00	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2016 12:00:00 AM	01/11/2016 12:00:00 AM		Permit Finaled	06/21/2016 12:00:00 AM	ADDRESS	33.96831	-118.30126	PV1 SFD TOTAL SYSTEM SIZE 6KW AC USING CENTRAL INVERTER SYSTEM. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76808	10041-10000-16850	754 S WALL ST	90014	14	126A211   123	5145005008	M2-2D	Central	Central City	Downtown Los Angeles		2260.00	Electrical	Electrical	Commercial			08/25/2010 12:00:00 AM	02/23/2011 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	ADDRESS	34.04061	-118.24966	Install a new 284KW PV system on the roof.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76809	15041-10002-40374	829 E 3RD ST	90012	14	129A215   260	5163007010	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	05/23/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.04601	-118.23547	04/08/16Changes to an approved set of plans. All changes are clouded under delta 6. Scope includes adding new receptacles for storage area and prep area. Also panels and a transformer on the single line diagram are changed from existing to new.  (((((plan check for new lighitng design. delta 4 changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76810	15041-10001-36772	2706 E CESAR E CHAVEZ AVE	90033	14	127-5A225  74	5180017002	C2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2042.00	Electrical	Electrical	Commercial			05/23/2017 12:00:00 AM			Corrections Issued	05/23/2017 12:00:00 AM	ADDRESS	34.04493	-118.20391	PC FOR CHANGES TO APPROVED SET FOR TITLE 24 REVISION. PERMIT PULLED UNDER 17041-10000-12549SCOPE INCLUDES CHANGES TO FIXTURES INSTALLED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76811	13041-10000-16278	1100 W WILSHIRE BLVD	90017	1	130-5A207 636	5143022018	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM			PC Approved	07/22/2013 12:00:00 AM	ADDRESS	34.05228	-118.26384	13041-10000-16278PLAN CHECK FOR TITLE 24 PART 6 ENERGY FOR A TENANT IMPROVEMENT (CHASE BANK) 1969 SQUARE FEET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76812	17041-10000-03105	10250 W SANTA MONICA BLVD 2630	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/31/2017 12:00:00 AM	04/07/2017 12:00:00 AM		Permit Finaled	06/30/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for power and energy for New Tenant ""THE BODY SHOP"" Ste. 2630.  Install new panels and its circuits, lights and receptacles. Total effected area: 585 sq.ft."	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76813	16041-10000-39321	6514 N BONNER AVE	91606	2	180B173   647	2336002013	R1-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1242.01	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2016 12:00:00 AM	11/07/2016 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.18889	-118.37358	Installation of new roof mounted solar PV array on existing single family dwelling.  Total system size = 3.1 kWac.  Central inverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76814	18041-10000-19466	12828 W RIVERSIDE DR	91607	4	168B161   460	2357033019	(T)(Q)RAS4-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	07/17/2018 12:00:00 AM		Permit Finaled	04/23/2020 12:00:00 AM	ADDRESS	34.15745	-118.41266	PC FOR NEW FIRE ALARM FOR A 4 STORY HOTEL. SCOPE INCLUDES NEW FACP, 6 RPS PANELS AND 319 DEVICES. Building permit: 16010-20000-05742	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76815	16041-30000-25426	1506 N BAY VIEW AVE	90744	15	036B205   802	7421015026	R1-1XL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2016 12:00:00 AM	08/04/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	33.79324	-118.27082	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (18) modules. Standard plan is not being used.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76816	10041-20000-15745	9434 W CHEROKEE LANE	90210	5	150B165    67	4387032016	RE15-1-H, RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.01	Electrical	Electrical	Commercial			08/12/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	02/28/2011 12:00:00 AM	ADDRESS	34.11079	-118.40008	49kw pv system for residentail.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76817	18041-10000-05049	4520 W ELECTRONICS PL	90039	13	162B205    11	5593012025	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			02/09/2018 12:00:00 AM	02/09/2018 12:00:00 AM		Permit Finaled	02/27/2018 12:00:00 AM	ADDRESS	34.14462	-118.27312	Plan check for a new replacement  frie alarm system in an existing building. Scope includes (1) panel and (95) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76818	19041-20000-02314	24061 W JENSEN DR	91304	12	193-5A089 169	2017011020	RA-1-H	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	1 or 2 Family Dwelling			01/18/2019 12:00:00 AM	01/18/2019 12:00:00 AM		Permit Finaled	05/02/2019 12:00:00 AM	ADDRESS	34.22313	-118.65074	PV1.  Install 2.835 kW roof mounted grid tied PV system.  (9) modules with 3 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76819	13041-10002-35606	11995 W BLUFF CREEK DR BLDG #4	90094	11	105B165   921	4211011037	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	03/20/2015 12:00:00 AM		Permit Finaled	08/20/2015 12:00:00 AM	ADDRESS	33.98218	-118.40255	Changes to approved set.  Load revisions.    (((CORE AND SHELL FOR NEW 2 STORY COMMERCIAL BUILDING OF APPROXIMATELY  36760 SF WITH NEW SURFACE PARKING LOT. TITLE 24 ENERGY FEE CHARGED UNDER BUILDING 3.  3 TOTAL BUILDINGS.  THIS IS BUILDING 4/5 IN THE SAME PARCELBLDG PERMIT: 13010-10000-04244)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76820	18041-20000-44911	18153 W PARTHENIA ST	91325	12	195B125   800	2769019036	[Q]CM-1VL	North Valley	Northridge	Northridge South		1152.02	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	PIN	34.22908883	-118.52906755	PV3.  Install 3.7 kW DC roof mounted grid tied PV system.  (10) modules with 3.8 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76821	14041-20000-32661	515 S FIGUEROA ST suite 1275	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/24/2014 12:00:00 AM	11/24/2014 12:00:00 AM		Permit Finaled	03/05/2015 12:00:00 AM	ADDRESS	34.05199	-118.25764	Plan check for energy only. TI to an existing office on the 12th floor of a high rise office building. New lighting (incl. emergency). 1,549sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76822	19041-10000-44564	5101 W FOUNTAIN AVE	90029	13	147A195   282	5544038024	R3-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM	10/31/2019 12:00:00 AM		Permit Finaled	04/05/2022 12:00:00 AM	ADDRESS	34.09532	-118.30091	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76823	11041-20001-01430	10210-10216 N CANOGA AVE Building C	91311	12	204B105   430	2747011039	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			02/01/2011 12:00:00 AM	02/01/2011 12:00:00 AM		Permit Finaled	02/08/2011 12:00:00 AM	ADDRESS	34.25581	-118.59713	CHANGES TO APPROVED PLANS. ADDITIONAL OF 2 MORE MODULES AND STRING IN EACH ARRAY. PLAN CHECK FOR NEW INSTALLATION OF ROOF MOUNTED 7.40KW PHOTOVOLTAIC SYSTEMS FOR BUILDING C. TO PLAN CHECK UNDER #10041-20000-20206	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76824	15041-10000-12219	7813 S BROADWAY	90003	8	105B189   475	6001013010	M1-1, M2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM	04/23/2015 12:00:00 AM		Permit Finaled	05/18/2015 12:00:00 AM	ADDRESS	33.96849	-118.27849	REMOVE EXISTING HID LIGHTING FIXTURES AND REPLACE WITH LED FIXTURES.  PLAN CHECK FOR ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76825	17041-10000-07570	443 N FAIRFAX AVE	90036	5	141B177  1285	5527031018	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			03/09/2017 12:00:00 AM	07/13/2017 12:00:00 AM		Permit Finaled	09/08/2017 12:00:00 AM	ADDRESS	34.0794	-118.36161	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL RETAIL SPACE. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA IS 2250 SQ. FT. B#17016-10000-03148	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76826	16041-20000-31034	18326 W SHEFFIELD LANE	91326	12	213B125   114	2870017031	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.03	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2016 12:00:00 AM	08/31/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.28312	-118.53297	Plan check for roof-mounted solar array on SFD. Interconnect with a 200A MSP. 5kW ungrounded system.(25) 255W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76827	19041-20001-07510	13733 W WYANDOTTE ST	91405	2	186B153   638	2216036010	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	1 or 2 Family Dwelling			03/01/2019 12:00:00 AM			PC Approved	03/29/2019 12:00:00 AM	ADDRESS	34.20318	-118.43255	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWdc and consists of (1) 7.6 kWac-rated inverter, (15) modules, (1) transformer, (1) battery back-up unit, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76828	15041-20001-16804	9301 N TAMPA AVE #25	91324	12	198B117    99	2761037004	C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.2392	-118.55379	08/27/2015 Changes to an approved set of plans. Changes include lighting fixture locations and new lights in the restroom and dispensary. All changes have been reflected on the Title 24 Compliance Forms.*****Previous Work Description*****Plan check for Title 24 only for Vanity District Salon(Chnage of use from Retail to hair salon). Total area: 942 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76829	15041-10000-19613	2867 W SUNSET PL	90005	10	133-5A201  80	5077013039	R5-2	Central	Wilshire	Wilshire Center - Koreatown		2122.04	Electrical	Electrical	Apartment			06/23/2015 12:00:00 AM	01/26/2016 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	34.0609	-118.2861	Full plan check for a new 6-story , 60-unit apartment building over a 2-level underground parking located in METHANE ZONE . Total 19-typical units. Main scope includes a 1600-Amp 3-phase 120/208V service equipment for the whole new building. T-24 area is 42228-SQ feet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76830	17041-10000-19783	10123 N OAKDALE AVE	91311	12	204B113   390	2726023001	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	Commercial			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/06/2017 12:00:00 AM	ADDRESS	34.25429	-118.56683	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76831	17041-10000-37304	12100 W WILSHIRE BLVD SUITE 1540	90025	11	126B145   209	4263002046	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			10/17/2017 12:00:00 AM	10/18/2017 12:00:00 AM		Issued	10/18/2017 12:00:00 AM	ADDRESS	34.0438	-118.46755	TITLE 24 PLAN CHECK ONLY FOR EXISITNG OFFICE AREA IN EXISTING HIGHRISE BUILDING. SCOPE OF WORK INCLUDES REPLACEMENT OF LIGHTING ONLY. TOTAL AFFECTED AREA = 4831 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76832	11041-10000-21403	1061 S BROXTON AVE	90024	5	132B149    64	4363024005	C4-2D-O	West Los Angeles	Westwood	Westwood		2653.01	Electrical	Electrical	Commercial			10/06/2011 12:00:00 AM	12/27/2011 12:00:00 AM		Permit Finaled	03/05/2012 12:00:00 AM	ADDRESS	34.06138	-118.44636	NEW REST. IN EXIST. TENANT SPACE,  FULL P/CHECK (Per applicant request)(TENANT IMPROVEMENT FOR FIVE GUYS BURGERS AND FRIES TO TAKE OVER AN EXISTING RESTAURANT SPACE.  WORK INCLUDES DEMOLITION OF EXISTING NON-STRUCTURAL WALLS, EXISTING STAIRS, EXISTING CEILING/SOFFITS, EXISTING FIXTURES, EXISTING ROOFTOP...(see additional comments)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76833	18041-20001-41179	11720 N PORTER VALLEY DR	91326	12	216B117   361	2822030003	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1081.02	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM			PC Approved	01/15/2019 12:00:00 AM	ADDRESS	34.28453	-118.55358	PV1.  Plan check for contractor design plan set; system redesign to centerfed main service panel.  (((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76834	18041-10000-09565	8500 W BEVERLY BLVD # 643	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM			PC Approved	03/15/2018 12:00:00 AM	ADDRESS	34.07587	-118.37754	TENANT IMPROVEMENT TO (E) RETAIL SPACE : relocating walls; new luminaires and lighting controlsPLAN CHECK IS FOR TITLE 24 AND 1 EA EMERGENCY LIGHTING CIRCUIT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76835	16041-10000-17654	800 E 62ND ST	90001	9	105B205   804	6007010007	M2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2392.02	Electrical	Electrical	Commercial			05/19/2016 12:00:00 AM	05/19/2016 12:00:00 AM		Permit Finaled	08/31/2016 12:00:00 AM	ADDRESS	33.98311	-118.26135	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. BUILDING IS 11118 SQFT CHECK FOR TITLE 24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76836	12041-20000-17562	22901 W VENTURA BLVD	91367	3	171B097   459	2042017009	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1370.00	Electrical	Electrical	Commercial			07/26/2012 12:00:00 AM	11/26/2012 12:00:00 AM		Permit Finaled	04/09/2013 12:00:00 AM	PIN	34.16573888	-118.62526362	"T.I. for restuarant.  Plan check for energy and power.  ""COMPLY WITH DEPARTMENT ORDER effective date 09/20/2011. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE""."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76837	13041-20000-33851	9546 N MELVIN AVE	91324	12	201B117   617	2761007028	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	1 or 2 Family Dwelling			12/05/2013 12:00:00 AM			Reviewed by Supervisor	12/19/2013 12:00:00 AM	ADDRESS	34.24405	-118.56	PV1 LOW FREQ TRANSFORMER. TOTAL SYSTEM SIZE 15KWAC. 69 MODULES AND 2 INVERTERS	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76838	17041-10000-40936	3145 S KELTON AVE	90034	5	120B157   277	4254006001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2717.01	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2017 12:00:00 AM	01/10/2018 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	34.02738	-118.42092	PC FOR INSTALLING ESS. SCOPE INCLUDES SINGLE POWERWALL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76839	14041-20000-21104	11846 W GARBER ST	91342	7	213B169   915	2530029005	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.08	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/05/2014 12:00:00 AM		Permit Finaled	10/01/2014 12:00:00 AM	ADDRESS	34.27682	-118.39083	PV1.  Install 5.46 kW roof-mounted, utility-interactive PV system.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76840	19041-10000-20061	400 W PICO BLVD	90015	14	126A207   194	5134017006	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	05/28/2019 12:00:00 AM		Permit Finaled	06/21/2019 12:00:00 AM	ADDRESS	34.03884	-118.26465	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76841	17041-10000-34723	20109 W PARTHENIA ST	91306	3	195B113   559	2781030002	RS-1	North Valley	Chatsworth - Porter Ranch	Winnetka		1134.21	Electrical	Electrical	1 or 2 Family Dwelling			09/27/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Issued	09/27/2017 12:00:00 AM	ADDRESS	34.22836	-118.57169	PC FOR PV SYSTEM USING 16 MODULES WITH OPTIIMIZERS AND CENTRAL INVERTER SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76842	18041-10000-38375	2235 S MIDVALE AVE	90064	5	126B157   624	4322005017	R1-1	West Los Angeles	West Los Angeles	Westside		2678.00	Electrical	Electrical	1 or 2 Family Dwelling			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	11/06/2018 12:00:00 AM	ADDRESS	34.04237	-118.43203	NEW ROOF MOUNTED PV SYSTEM USING MICROINVERTERS. NEW PV SUBPANEL TYING TO AN EXISTING PV SYSTEM. (5) MODULES AND (5) MICROINVERTERS. TOTAL SYSTEM SIZE 1.65KWDC /1.4KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76843	16041-10000-12885	8155 N VAN NUYS BLVD	91402	6	192B149   536	2210011029	[Q]C2-2-CDO, [Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			04/13/2016 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	10/10/2019 12:00:00 AM	ADDRESS	34.21922	-118.44896	ADAPTIVE REUSE OF EXISTING 13 STORY COMMERCIAL BUILDING CONVERTED INTO 192 RESIDENTIAL UNITS. (2) services: 3000A, 4000A. (7) Typical units. Total common area: 37,706 sq.ft.  Fire alarm variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76844	10041-20000-09299	6844 N DE SOTO AVE	91306	3	183B109   822	2137012027	(Q)C1-1VL, C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	Commercial			05/18/2010 12:00:00 AM			PC Info Complete	05/18/2010 12:00:00 AM	PIN	34.19447423	-118.58747412	energy plan check wingstop restaurant	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76845	18041-10000-42958	6250 N SYLMAR AVENUE MALL	91401	6	178-5A151 239	2240010904	[Q]PF-1-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1282.10	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	03/03/2021 12:00:00 AM	ADDRESS	34.18377	-118.4464	Energy plan check for a LIBRARY TI ; scope includes new lighting and equipment with a total area of 6850-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76846	14041-20000-27277	737 W 33RD ST	90731	15	006B197   258	7467002002	RD2-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2976.02	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2014 12:00:00 AM	10/03/2014 12:00:00 AM		Permit Expired	10/27/2016 12:00:00 AM	ADDRESS	33.7141	-118.29244	PV1.  Install 4.2 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76847	13041-10001-35510	12255 N GERALD AVE	91344	12	216B137    22	2609014029	RE11-1	North Valley	Granada Hills - Knollwood		YES	1066.02	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	02/13/2014 12:00:00 AM	ADDRESS	34.2925	-118.49113	Expedited RSES plan check per applicant.{{PV1, Install 6.75 kW DC roof-mounted solar array for a tw story house, interconnect with main service panel. (1)Transformerless inverter(s): Solaredge SE 6000A-US. (27) modules: Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76848	18041-20001-23221	5077 N HOOD DR	91364	3	171B113   495	2175020012	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2018 12:00:00 AM			PC Approved	07/17/2018 12:00:00 AM	ADDRESS	34.1618	-118.56758	Expedite per appliant requestPlan check for addition PV  and battery back up system to existing PV system, additional PV system size: 7.6kWac with 30 modules and 1 inverter(7.6kW) and 9.8kW LG CHEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76849	18041-20000-40541	4435 N BELLINGHAM AVE	91604	2	165B165   236	2364003078	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	01/03/2019 12:00:00 AM	ADDRESS	34.15138	-118.39882	PV1.  Install 11.34 kW roof mounted grid tied PV system.  (36) modules with (2) 5.2 kW rated string inverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76850	19041-10001-14656	970 N MORAGA DR	90049	5	141B145   222	4368019023	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM			PC Approved	09/05/2019 12:00:00 AM	ADDRESS	34.08202	-118.46797	Expedite per applicant request.Plan check for a 17.6KW AC / 17KW DC roofmounted system with (1) load center, (2) inverters, (54) modules and optimizers interconnecting through the service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76851	17041-10000-46202	10250 W SANTA MONICA BLVD # 1400	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/26/2017 12:00:00 AM	03/13/2018 12:00:00 AM		Permit Finaled	07/03/2018 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full plan check for first time tenant/restaurant ""CRACK SHACK"" ste. 1400 on Westfield Century City"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76852	11041-10003-07792	401 E CENTER WAY	90045	11	087B157    97	4129026911	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey	YES	9800.28	Electrical	Electrical	Commercial			06/19/2012 12:00:00 AM			PC Approved	06/19/2012 12:00:00 AM	PIN	33.93790872	-118.42837934	REVISIONS TO PERMITTED SET OF PLANS FOR TEMPORARY POWER IN CONSTRUCTION OF CUP BUILDING AT LAWAREVISIONS INCLUDE FEEDER # 11 OF MSB INTERCHANGED WITH # 13 AND ALL FEEDERS ARE NOW COPPER FEEDERS; AND FEEDER CIRCUIT BREAKER # 15  SIZED UP TO 800A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76853	17041-20002-14632	8945 N NEVADA AVE	91304	12	195B101    50	2010021008	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM			PC Approved	07/07/2017 12:00:00 AM	ADDRESS	34.23329	-118.60775	07/07/2017 Changes to an approved set of plans. Changes have been made to the inverters and modules. System size of 10.4 kWac has remained the same.*****Previous Work Description*****Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (37) modules, and (1) load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76854	11041-20000-23492	3434 S GRAND AVE 1st Flr	90007	9	118-5A203 116	5122030020	MR1-2	South Los Angeles	Southeast Los Angeles	South Central		2311.00	Electrical	Electrical	Commercial			11/02/2011 12:00:00 AM	11/07/2011 12:00:00 AM		Permit Finaled	01/19/2012 12:00:00 AM	ADDRESS	34.01912	-118.27658	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT ON SOUTH SIDE 1ST FLOOR. ADMINISTRATION AREA. PERMIT FOR NEW CKTS, PANELS, AND EQUIPMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76855	18041-20001-48286	403 S HIGHLAND AVE	90036	4	135B185   254	5507013001	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2018 12:00:00 AM			PC Approved	01/02/2019 12:00:00 AM	ADDRESS	34.06668	-118.33875	EXPEDITE PER APPLICANT'S REQUESTPC FOR NEW ROOFTOP PV SYSTEM FOR EXISTING SFD AND DETACHED GARAGE.SYSTEM IS 11.4 KW AC, (38) AC MODULES, (38) 370 DC OPTIMIZERS, (1) 11.4 KW AC INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76856	17041-20000-14641	4161 N FARMDALE AVE	91604	2	162B169    52	2368022016	R1-1-RFA-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.02	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2017 12:00:00 AM	06/15/2017 12:00:00 AM		Permit Finaled	12/21/2017 12:00:00 AM	ADDRESS	34.14418	-118.38128	Plan check for the addition of a PV1 roof-mounted PV system and a Tesla AC Powerwall to an existing PV system. PV system addition size is 3 kWac and consists of (1) inverter, (8) modules, and (1) load center. Tesla AC Powerwall rating is 7 kWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76857	19041-10000-14092	110 E 22ND ST	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			04/17/2019 12:00:00 AM	04/17/2019 12:00:00 AM		Permit Finaled	05/21/2019 12:00:00 AM	ADDRESS	33.72668	-118.27682	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76858	19041-10000-36566	8 S CHESTER PL	90007	1	123A203   138	5124029011	[Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.20	Electrical	Electrical	Commercial			09/26/2019 12:00:00 AM	10/11/2019 12:00:00 AM		Permit Finaled	11/04/2019 12:00:00 AM	ADDRESS	34.03102	-118.27718	[EPLAN] PLAN CHECK FOR ROOF MOUNTED 10KVA(AC)11.6KW(DC) PV2 SYSTEM CONNECTED TO EXISTING 800 SERVICE  COMMERCIAL BUILDING INTERCONNECTION	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76859	14041-10000-11162	777 S FIGUEROA ST #2850	90017	14	129A207    79	5144009047	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			04/28/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	08/22/2014 12:00:00 AM	ADDRESS	34.04828	-118.26116	PLAN CHECK FOR ENERGY ONLY. PERMIT TO Be pulled at EPC counter only. Emergency lighting installed in high rise. STE 2850. Scope of lighting work is in waiting room only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76860	17041-10000-19897	9006 N MERCEDES AVE	91331	6	195B157   286	2627013017	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	07/31/2017 12:00:00 AM	ADDRESS	34.23324	-118.42138	PC FOR PV SYSTEM. RATED 10.7KW AC USING AC MODULES 31 TOTAL	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76861	10041-10001-16266	5151 W WILSHIRE BLVD	90036	4	135B181   919	5507022016	C4-2D	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Public Safety Only			07/12/2011 12:00:00 AM	07/12/2011 12:00:00 AM		Permit Finaled	08/24/2011 12:00:00 AM	ADDRESS	34.06244	-118.34233	INSTALLATION OF A SPRINKLER / CENTRAL STATION  MONITORING SYSTEM.  ADDING AN ADDITIONAL 118 DEVICES TO THE PREVIOUSLY APPROVED 12 DEVICES AND UPGRADING THE PANEL. <<<<<<<<<<CHANGE TO PREVIOUSLY APPROVED PLANS FIRE ALARM SYSTEM, ADDITION OF 100+ DEVICES>>>>>>>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76862	13041-20001-00565	17260 W RAYEN ST PV-1	91325	12	195B133   211	2690013012	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	09/11/2014 12:00:00 AM	ADDRESS	34.23207	-118.5107	Modifications to approved set.  Relocation of non-roof mounted equipment and additional AC disconnect.  (((PV-1. Coffin Residence. 12.48kW.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76863	13041-20000-20409	1232 S CLOVERDALE AVE	90019	10	129B181   198	5084032016	R3-1-O	Central	Wilshire	P.I.C.O.		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2013 12:00:00 AM	08/21/2013 12:00:00 AM		Permit Finaled	10/15/2013 12:00:00 AM	ADDRESS	34.05265	-118.34959	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 6.5 KW USING 20 MODULES. CENTRAL INVERTER WITH ISOLATION TRANSFORMER. 4 STRINGS. NONSTANDARD PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76864	15041-10000-15803	748 S ALAMEDA ST Bldg B	90021	14	123A215   242	5166032027	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/22/2015 12:00:00 AM	05/27/2015 12:00:00 AM		Permit Finaled	06/19/2015 12:00:00 AM	ADDRESS	34.03247	-118.23433	PC FOR T24. TI. CHANGE OF USE FROM WHAREHOUSE TO FOOD PROCCESSING WHOLESALE. TOTAL AREA 4106 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76865	16041-10000-31175	11801 W MISSISSIPPI AVE	90025	11	123B149   359	4262033020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/01/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	04/11/2017 12:00:00 AM	ADDRESS	34.03444	-118.45125	Title 24. PC for energy only to an existing office building. Scope of work is being done in lobby, parking deck, restroom, and service area. Addin new lighting and power. Total sqft = 4011.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76866	14041-20000-32518	17440 W NORDHOFF ST	91325	12	198B129   460	2768023018	RA-1	North Valley	Northridge	Northridge South		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			11/21/2014 12:00:00 AM	01/05/2015 12:00:00 AM		Permit Finaled	03/31/2015 12:00:00 AM	ADDRESS	34.23567	-118.51484	pv1install roof mounted pv system sized 12.0kw interconnected with msp.(36) sunpower 327w modules(2) aurora 6k transformerless inverters	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76867	15041-10000-17880	200 WORLD WAY TER 2 #271	90045	11	093B165   167	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/09/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	33.94558	-118.4039	PC FOR POWER AND ENERGY. FIRST TIME TENANT FOOD AND BEVERAGE KIOSK IN AIRPORT. TER 2 UNIT 271. PEPITA CANTINA, FULL PC. TOTAL SQ FT. 992.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76868	12041-20000-06894												Electrical	Electrical	Commercial			03/27/2012 12:00:00 AM			PC Approved	03/27/2012 12:00:00 AM					N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76869	15041-10000-20764	600 WORLD WAY TERM 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM	07/15/2015 12:00:00 AM		Permit Finaled	01/16/2019 12:00:00 AM	ADDRESS	33.9427	-118.40223	ALTERATION OF AN OPEN AREA TO A DUTY FREE STORE DFS T6PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76870	15041-10000-37426	5880 W CENTINELA AVE	90045	11	102B169    61	4103005002	M1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2761.00	Electrical	Electrical	Commercial			11/05/2015 12:00:00 AM	01/27/2016 12:00:00 AM		Permit Finaled	09/01/2016 12:00:00 AM	ADDRESS	33.9764	-118.38423	FULL PC FOR HAZARDOUS LOCATION, TI IN AN AUTO DEALERSHIP GARAGE, SCOPE OF WORK INCLUDES  LIGHITNG AND RECEPTACLES ON THE AUTO GARAGE PORTION.  TOTAL SQ. FT. 9680.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76871	16041-10000-05597	18547 W WILLARD ST	91335	12	192B125   869	2103006028	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			02/17/2016 12:00:00 AM	02/17/2016 12:00:00 AM		Permit Finaled	03/16/2016 12:00:00 AM	ADDRESS	34.21848	-118.53791	PV1, rooftop solar installation 4.1kW Ac system(19) HYNDAI HiS-S260RG(19) M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76872	10041-10000-01506	5200 W CENTURY BLVD	90045	11	090B173   114	4129031018	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Public Safety Only			01/28/2010 12:00:00 AM	01/28/2010 12:00:00 AM		Permit Finaled	02/25/2010 12:00:00 AM	ADDRESS	33.94516	-118.37049	New fire alarm system for elevator fire detection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76873	17041-30000-19809	11136 N HAYVENHURST AVE	91344	12	210B137   352	2681016017	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			06/13/2017 12:00:00 AM	06/13/2017 12:00:00 AM		Permit Finaled	08/15/2017 12:00:00 AM	ADDRESS	34.27307	-118.49326	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (26) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76874	15041-20001-41087	132 N SWALL DR 1-14	90048	5	138B169   260	4335001007	R3-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			01/11/2017 12:00:00 AM	07/11/2017 12:00:00 AM		Permit Finaled	11/27/2018 12:00:00 AM	ADDRESS	34.07622	-118.38569	01/11/2017 Changes to an approved set of plans. Changes have been clouded and marked as Delta C. Changes have been to the indoor lighting floor plans and there has been an addition of cooktops to all units and speed ovens to (2) units. Unit panel feeders have changed.*****Previous Work Description*****NEW APARTMENT BUILDING 800 AMP SERVICE.  FULL PLAN CHECK.  FIRE VARIANCE TO FILE AT LATER TIME.BUILDING APPL# 15041-30000-00764	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76875	19041-20000-01216	8440 N BALBOA BLVD 104	91406	12	192B133   538	2689019016		North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	Commercial			01/10/2019 12:00:00 AM	01/10/2019 12:00:00 AM		Issued	01/10/2019 12:00:00 AM	ADDRESS	34.22397	-118.50243	plan check for power, first time tenant.  partial permit fees covered under TI permit, see below.((((ti to an existing commercial building.  adding new lighting new controls to new panels.  newly connected load < 400 amps.  plan check for indoor energy only. application number 18041-20000-48158))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76876	11041-10000-25028	6443 N CANOGA AVE	91367	3	180B105    57	2146005028	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			11/22/2011 12:00:00 AM	03/15/2012 12:00:00 AM		Permit Finaled	05/03/2012 12:00:00 AM	ADDRESS	34.18783	-118.59772	New restaurant, change of use from retail.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76877	16041-20000-11968	17088 W KINGSBURY ST	91344	12	207B133   634	2695007023	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			04/06/2016 12:00:00 AM	04/06/2016 12:00:00 AM		Permit Finaled	04/28/2016 12:00:00 AM	ADDRESS	34.26347	-118.50525	Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 150A.System size: 7.8kW (4.2+3.6). Ungrounded system. (35) 280W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76878	14041-20003-30857	7880 N VAN NUYS BLVD	91402	6	189B149   638	2212028014	[Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			06/10/2016 12:00:00 AM	06/22/2016 12:00:00 AM		Permit Finaled	08/17/2016 12:00:00 AM	ADDRESS	34.21541	-118.4462	06-10-16 Changes of an approved set of plans. Changes made to electrical service distribution equipment and existing panel. Changes apply to delta  1 only. {{{{{{{04/28/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. Changes have been made to the electrical service distribution equipment and existing panels have been re-fed. *****Previous Work Description*****Complete gut and rebuild. new service, new equipment, new lighting. This is a vanilla shell. 800A service. PC for power and energy. TI will be submitted by tenant at another time. zoned for retail use.}}}}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76879	19041-10000-24679	6137 N LANKERSHIM BLVD STE A	91606	2	177B169   474	2338006027	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	NoHo		1241.05	Electrical	Electrical	Commercial			06/26/2019 12:00:00 AM	06/27/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.18226	-118.38534	remove HID fixtures and replace with new LED fixtures (Indoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76880	14041-20000-28915	14005 W SYLVAN ST	91401	2	177B153   172	2239009007	RS-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1282.20	Electrical	Electrical	1 or 2 Family Dwelling			10/20/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Expired	11/18/2016 12:00:00 AM	ADDRESS	34.18451	-118.43797	PV1 SFD. TOTAL SYSTEM SIZE 6.6KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76881	17041-20000-21308	5950 N LAUREL CANYON BLVD	91607	2	177B165   769	2340005037	C2-1VL	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1239.02	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Issued	08/15/2017 12:00:00 AM	ADDRESS	34.17861	-118.39631	PV2.  Install 60 kW roof mounted grid tied PV system on an (E) carwash roof.  (200) modules with Enphase C250 microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76882	18041-10000-17409	2805 S SAN PEDRO ST	90011	9	118-5A207 124	5128013028	CM-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	Commercial			05/10/2018 12:00:00 AM	05/11/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	34.01977	-118.26268	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76883	13041-10004-26817	5900 W CENTER DR	90045	11	102B169   964	4104023016	C2-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	Apartment			08/10/2015 12:00:00 AM			PC Approved	10/02/2015 12:00:00 AM	ADDRESS	33.97559	-118.38853	8/10/2015CHANGE OF ENGINEER.  PLAN CHECKER TO VERIFY LETTER FOR CHANGE OF ENGINEER BEFORE FINAL APPROVAL OF PLANS.  CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 7.  CHANGES INCLUDE REVISIONS TO THE LIGHTING AND REVISIONS TO THE ENERGY CALCS.   (((New 327-unit apartment building at Howard Hughes Center.  Power and energy.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76884	14041-10000-12932	189 S THE GROVE DR # Q-30	90036	4	138B177  1132	5512003042	(T)C2-2D-O	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			05/14/2014 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	09/09/2015 12:00:00 AM	ADDRESS	34.07125	-118.35662	PLAN CHECK FOR POWER AND ENERGY FOR NIKE STORE AT THE GROVE. EXISTING SERVICE, NEW LOADS AND PANELS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76885	19041-10000-34956	21938 W WALTERS DR	91311	12	198B101   336	2727024001	(T)(Q)RD3-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1132.37	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	09/04/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.23558	-118.60597	Energy plan check for a PV1 3.4KW DC / 2.9KW AC roof mounted microinverter system. Scope includes (12) modules, and (1) subpanel interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76886	14041-10001-14671	2053 W VENICE BLVD	90006	10	126B193   221	5075013019	C1-1VL-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2212.10	Electrical	Electrical	Commercial			09/25/2014 12:00:00 AM	10/20/2014 12:00:00 AM		Permit Finaled	07/17/2015 12:00:00 AM	ADDRESS	34.04374	-118.30174	Full plan check for power and energy.  ttenant improvement. newly connected load > 400 amps.  [[[[800 Amp service upgrade and energy  were previously approved under 14041-10000-14671 and 14041-20000-09441 ]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76887	16041-20001-45007	13078 E MINDANAO WAY 116	90292	11	105B153    45	4212009***	(Q)RD2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/06/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	33.98673	-118.43554	COPY OF LOST PLANS FOR ELEVATOR LOBBY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76888	14041-20000-34299	8564 S BROADWAY	90003	9	097-5A203 324	6040010015	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2397.02	Electrical	Electrical	Commercial			12/11/2014 12:00:00 AM	02/19/2015 12:00:00 AM		Permit Finaled	05/15/2015 12:00:00 AM	ADDRESS	33.9604	-118.27809	Plan check for energy only. New lighting (incl. emergency) in bank. NEW 24HR VESTIBULE. MODIFIED TELLER LINE. NEW  ACCESSIBLE MEN'S AND WOMEN'S RESTROOM. Lighting in these areas, and in main bank lobby near teller area. Approx. 6,000sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76889	17041-10000-06705	2515 W AVENUE 33	90065	1	150B213    63	5456001044	RD3-1	East Los Angeles	Northeast Los Angeles	Glassell Park		1863.02	Electrical	Electrical	Commercial			03/02/2017 12:00:00 AM	03/02/2017 12:00:00 AM		Permit Finaled	03/29/2017 12:00:00 AM	ADDRESS	34.11073	-118.23488	PC FOR ENERGY, T24 ONLY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES. (OUTDOOR) TOTAL AREA 9950 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76890	17041-20000-08283	4201 N ALEMAN DR	91356	3	165B113   192	2178008024	A1-1-H	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.14602	-118.56512	pv1install roof mounted pv system sized 12kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76891	13041-20000-32100	19801 W NORDHOFF PL	91311	12	198B113   149	2761001046	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			11/15/2013 12:00:00 AM	12/16/2013 12:00:00 AM		Permit Finaled	09/15/2014 12:00:00 AM	ADDRESS	34.23568	-118.56464	"PV2 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 993.6KWAC. 4030 MODULES AND 36 INVERTERS "" $0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76892	18041-20002-34143	11444 W ALBATA ST	90049	11	135B145   719	4365017008	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2019 12:00:00 AM			PC Approved	05/22/2019 12:00:00 AM	ADDRESS	34.06314	-118.4621	05/22/2019 Changes to an approved set of plans. Roof layout has been revised and minor changes were made to the single line diagram.*****Original Scope of Work*****PV1.  Install 11.025 kW DC roof mounted grid tied PV system.  (35) modules with 11.4 kW rated string inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76893	18041-10000-27462	19191 S VERMONT AVE 5th floor	90502	15	057B197     7	7351031021	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			07/23/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	12/27/2018 12:00:00 AM	ADDRESS	33.85656	-118.29099	PLAN CHECK FOR POWER AND ENERGY FOR - TENANT IMPROVEMENT ON THE 5TH FLOOR OF A 10 STORY OFFICE BUILDING 18,611 SQFT. TYPE B OCCUPANCY - TOTAL NEW CONNECTED LOAD >400A CONNECTED TO EXISTING DISTRIBUTION EQUIPMENT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76894	18041-10000-05899	3303 N NORTH BROADWAY FLR 2, 3	90031	1	138A225    15	5208012021	[Q]C4-1VL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	1992.02	Electrical	Electrical	Commercial			02/16/2018 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	10/04/2021 12:00:00 AM	ADDRESS	34.07394	-118.20626	PC for power and energy for medical office building TI. Installing new panels, lights, receptacles and equipment. Total 39235sqft. B# 18016-10000-04041.OFFICE INTERIOR TI: INTERIOR PARTITIONS AND CEILING BUILD OUT  40,980 SQ FT OF SPACE (2ND AND 3RD FLOORS)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76895	19041-10000-01293	961 S GRETNA GREEN WAY	90049	11	129B145   957	4264023016	R1-1	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	1 or 2 Family Dwelling			01/11/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	06/28/2019 12:00:00 AM	ADDRESS	34.0466	-118.47066	PLAN CHECK FOR ROOF MOUNTED 76KVA PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE7600H-US) WITH 29 MODULES USING P400 OPTIMIZERS AND 2 13.5KWH AC BATTERIES(TESLA POWER WALLS)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76896	17041-10000-12281	6151 W CENTURY BLVD STE A	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/14/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Issued	07/27/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	"Plan check for Title 24 only in existing space Office T.I. (MIDWAY CAR RENTAL, SUTE ""A"") Total area: 3434 sq ft"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76897	19041-10000-45043	1130 N ANGELO DR	90210	5	144B157   314	4358008026	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2612.00	Electrical	Electrical	1 or 2 Family Dwelling			11/18/2019 12:00:00 AM	01/28/2020 12:00:00 AM		Permit Finaled	11/21/2022 12:00:00 AM	ADDRESS	34.09012	-118.43123	FULL PLAN CHECK FOR A NEW 800A SERVICE 120/240 SINGLE PHASE, 3W . SCOPE INCLUDES NEW ELEVATOR, EV CHANRGER, NEW PANELS AND CKTS. NOTE. PORTION OF PERMIT FEE IS UNDER BUILDING COMBO PERMIT. PER BUILDING PERMIT # 19010-20000-04425	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76898	12041-20000-00629	300 S GRAND AVE 35th Floor	90013	9	130-5A211  18	5149010026	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			01/10/2012 12:00:00 AM	03/12/2012 12:00:00 AM		Permit Finaled	06/04/2012 12:00:00 AM	PIN	34.05243427	-118.25124731	T.I. to existing high rise building on the partial of 35th floor.  Install general/emergency lighting.  Plan check for energy only, permit fee is under INSPECTION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76899	17041-20001-31690	3019 E ASBURY ST	90065	1	147A217    68	5454031025	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	1 or 2 Family Dwelling			09/05/2017 12:00:00 AM			PC Approved	01/24/2018 12:00:00 AM	ADDRESS	34.09865	-118.23001	Expedited plan check fee.  PV1. Install 5.85 kW roof mounted grid tied PV system.  (18) modules with 5kW rated string inverter.  13.5 kWh backup energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76900	17041-10000-42023	2542 N CORRALITAS DR	90039	13	148-5A211 197	5440029021	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1873.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2017 12:00:00 AM	02/22/2018 12:00:00 AM		Issued	02/22/2018 12:00:00 AM	ADDRESS	34.10042	-118.25171	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL BUILDING. TOTAL SYSTEM SIZE IS 6.3KWdc / 6.0KWac.(21)MODULES-SOLARWORLD SW 300 MONO(11)OPTIMIZIERS-TIGO MM2ES50(2)INVERTERS-PVI-6000-OUTD-US-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76901	16041-10000-42953	8451-8457 W BLACKBURN AVE 1-6	90048	5	138B173   865	5511032013	R3-1-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Apartment			12/07/2016 12:00:00 AM			PC Info Complete	01/22/2018 12:00:00 AM	ADDRESS	34.07239	-118.37503	07/21/2023 marked as PC only, applicant no longer needs this plan check.Plan check for methane mitigation system(Methane Gas Detection System) on 4 story, 18 unit apt. Total Methane devices: 13 and 1 gas detection panel system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76902	09041-20002-16607	7122 W BEVERLY BLVD	90036	5	138B181   432	5513002032	C2-1LD	Central	Wilshire	Mid City West		2140.00	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM			PC Approved	03/17/2010 12:00:00 AM	ADDRESS	34.07599	-118.34481	Photovoltaic system for commercial bldg. Revsion to previously approved plan 09041-30001-16607. Change was done by connecting one solar panel combining to other two arreys and making three phase system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76903	18041-30000-06157	1100 S MAIN ST	90015	14	126A209   205	5139016024	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/20/2018 12:00:00 AM			PC Approved	02/20/2018 12:00:00 AM	ADDRESS	34.03879	-118.25809	T-24 PC FOR ENERGY ONLY, SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES TO AN EXISTING COFFEE STORAGE SHOP. TOTAL SQ. FT. 2,068.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76904	10041-10000-05878	10401 W VENICE BLVD #101B	90034	11	117B165    64	4314003039	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.01, 2699.02	Electrical	Electrical	Commercial			03/31/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	01/28/2011 12:00:00 AM	ADDRESS	34.02052	-118.40433	T.I. for existing restuarant (Kabab Grill).  Install general lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76905	16041-10000-34621	740 S WESTERN AVE #117	90005	10	132B193   501	5093007029	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			09/29/2016 12:00:00 AM			PC Approved	09/29/2016 12:00:00 AM	ADDRESS	34.05845	-118.30891	PC FOR ENERGY ONLY. T.I. CHANGE OF FROM BAKERY TO COFFE SHOP. TOTAL AREA 965 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76906	15041-20000-17250	18636 W WILLARD ST	91335	12	189B121    49	2103008032	RS-1	South Valley	Reseda - West Van Nuys	Reseda		1310.10	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Expired	06/29/2017 12:00:00 AM	ADDRESS	34.21825	-118.53991	PV1. Standard plan. Install roof mounted solar system sized 5 KW. Interconnected with main service panel.(25) KU 260 Modules(1) PVI 5000-TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76907	15041-20000-17255	14324 W DYER ST	91342	7	222B153   738	2508018024	R1-1	North Valley	Sylmar	Sylmar		1070.10	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/04/2015 12:00:00 AM		Permit Finaled	08/13/2015 12:00:00 AM	ADDRESS	34.3023	-118.44525	PV1. Standard plan. Install roof mounted solar system sized 6 KW. Interconnected with main service panel.(32) KU 260 Modules(1) PVI 6000-TL Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76908	15041-10000-00206	12543 W PIERCE ST	91331	7	210B161   810	2536011***	(Q)RD2-1	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2015 12:00:00 AM	01/16/2015 12:00:00 AM		Permit Expired	02/10/2017 12:00:00 AM	ADDRESS	34.2724	-118.40652	PV1 Standard Plan with 3.6KW roof-mounted system including (1) ABB PVI-3.6-TL inverter, (1) load center and (17) Kyocera KU2556XCA modules.Note. plan required to be clear at Metro/VN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76909	16041-10000-00991	4341 S MAIN ST 1-4	90037	9	114A203   383	5111011002	CM-1	South Los Angeles	Southeast Los Angeles			2318.00	Electrical	Electrical	Commercial			01/12/2016 12:00:00 AM	11/15/2016 12:00:00 AM		Permit Finaled	04/25/2017 12:00:00 AM	ADDRESS	34.00444	-118.27427	New warehouse total area 8,190 sq.ft (indoor+outdoor), 400 MSA. PC for Power and Energy (changed of use from apartment to warehouse)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76910	14041-20001-17690	1755 N GLENDALE BLVD	90026	13	144A209   285	5423006033	[Q]CM-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1955.00	Electrical	Electrical	Commercial			12/01/2014 12:00:00 AM			PC Approved	12/01/2014 12:00:00 AM	ADDRESS	34.08742	-118.25984	12.1.2014 - Plan check for modifications to approved set (power only). Remove Heat Pumps and Air Handling units from panel DP. Add a 10.8VA  AC unit to panel DP. Add 11 new radiant heater branch circuits to panel PP1. Reduce load of existing radiant heaters in panel PP1, reduce breaker size to 15A from 20A.Delta 1 changes only.[TI for (N) yoga studio.  Power and energy per applicant request.]	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76911	15041-10000-18113	1888 CENTURY PARK EAST 9th Flr	90067										Electrical	Electrical	Commercial			06/11/2015 12:00:00 AM			PC Approved	06/11/2015 12:00:00 AM				Energy plan check for an office T.I located at the 9th floor of a high rise building. main scope is converting a storage room into (3) offices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76912	15041-20005-07849	2901 W LOS FELIZ BLVD	90039	13	159B205   502	5594006020	[Q]C4-1XL-RIO, [T][Q]M1-1VL-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM			PC Approved	05/27/2016 12:00:00 AM	ADDRESS	34.12774	-118.26247	05/27/2016 Changes to an approved set of plans. All changes have been clouded and marked as Delta 8. Changes included revisions to the Title 24 Compliance Forms03/29/2016. changes to approved set of plans. plancheck only. changes to the circuit and the location of receptacles in the photoarea.09-04-2015 Change to an approved set of plans. Changes include relocation of hearing booths and alter lighting for photo center. Changes apply to Delta 6 only. **************************************************************08/05/2015 Changes to an approved set of plans. All changes have been clouded and marked Delta 5. Changes include the addition of  receptacles and lights onto existing circuits.*****Previous Work Description*****Change to approved set. Plan check for Addition of 2  new hearing exam booths to Costco. No light is being add to the 2 new booth; light is part of the booth. {{{{{{PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR COSTCO OPTOMETRY ROOMS. NOT A MEDICAL ( CONSULTATION ONLY) 615 SQFT.}}}}}}}	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76913	14041-20000-32221	12252 W OTSEGO ST	91607	2	171B165   827	2356014023	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1240.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	12/12/2014 12:00:00 AM	ADDRESS	34.16289	-118.40045	PV1 SFD. TOTAL SYSTEM SIZE 9.2KW AC USING 2 CENTRAL TRANSFORMERLESS INVERTERS. TOTAL OF 44 MODULES. USING STANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76914	13041-20001-01326	9101 N SEPULVEDA BLVD	91343	7	198B145   385	2656026012	C2-1, RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM	07/08/2013 12:00:00 AM		Permit Finaled	08/27/2013 12:00:00 AM	ADDRESS	34.23576	-118.4679	(((SUPPLEMENTAL APPLICATION FOR PLAN CHECK. CHANGES TO APPROVED SET OF PLANS. CHANGES CLOUDED. CHANGE IN LIGHTING )))Plan check for energy and power. Existing service. Affected load is greater than 400A. Laundromat. 6724sqft. Smoke shop, PANEL SA, is on a seperate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76915	18041-20000-42867	11588 W PICO BLVD 1-21	90064	11	123B153   631	4260034024	[Q]C2-1VL-CDO	West Los Angeles	Palms - Mar Vista - Del Rey	West Los Angeles Sawtelle		2712.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	02/07/2020 12:00:00 AM		Permit Finaled	06/03/2022 12:00:00 AM	ADDRESS	34.03244	-118.44364	PC for power and energy. Scope includes  a new 800A 120V/240V 3 phase 4 wire service/distribution board, new panels, and new circuits. Total affected area is 7993 sq. ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76916	10041-10000-03602	8985 W VENICE BLVD	90034	10	120B165  1489	4313022017	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms	YES	2701.00	Electrical	Electrical	Commercial			03/01/2010 12:00:00 AM	05/06/2010 12:00:00 AM		Permit Finaled	07/21/2010 12:00:00 AM	ADDRESS	34.02733	-118.39241	T.I. for bank (Chase).  Install general and emergency lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76917	13041-10001-36150	16656 W GLEDHILL ST	91343	12	198B137   169	2687015006	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2013 12:00:00 AM			PC Approved	02/11/2014 12:00:00 AM	ADDRESS	34.24211	-118.49571	Expedited RSES plan check per applicant request.{{PV1, ROOF-MOUNTED SOLAR INSTALLATION , INTERCONNECTING TO (E) 200A MAIN IN A 2-STORY HOUSE. non-standard plan. SYSTEM SIZE IS 7 kW DC. (28)power  optimizers:Solaredge Op250-LV-AH4SM-2NA-Z   (28)Modules: Trina solar #TSM-250PA05.18(1) Transformerless inverter(s:)Solaredge #SE6000A-US.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76918	18041-10000-29912	14640 W ROSCOE BLVD	91402	6	192B149   407	2210010012	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			08/08/2018 12:00:00 AM	05/10/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.22128	-118.45128	PLAN CHECK FOR TITLE 24 ONLY - TENANT IMPROVEMENT FOR NEW STARBUCKS COFFEE TO INCLUDE NEW PARTITION WALLS, LIGHTING FIXTURES, CASE WORK, MEP. TOTAL AFFECTED AREA = 1847 SF.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76919	19041-20001-35585	16760 W RAYEN ST	91343	12	195B137   394	2688031017	RA-1	North Valley	Northridge	Northridge South		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	12/10/2019 12:00:00 AM	ADDRESS	34.23199	-118.49815	$0 FINAL FEE DUE TO SB1222 AND AB1414SUPPLEMENTAL PLAN CHECK FOR CHANGES TO APPROVED SET, CHANGE TO COVER PAGE, LAYOUT PAGE, AND SINGLE LINE PAGE. SINGLE LINE ARRANGEMENT CHANGED, ADDITION OF A SUB PANEL, AND AC DISCONNECT. CHANGE MADE TO MAIN PANEL, PANEL UPGRADED FROM SPLIT BUS 200A TO NON SPLIT 225A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76920	17041-20000-44594	911 N TIONE ROAD	90077	5	141B149    40	4369024011	RE20-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2018 12:00:00 AM			PC Approved	02/22/2018 12:00:00 AM	ADDRESS	34.08571	-118.45269	Plan check for power only.  New three-story single family dwelling with attached garage.  1200A 120/208V 3ph 4w service.  75 kVA optional standby generator.  Building permit application #15010-30000-04702.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76921	12041-20001-23575	800 N ALAMEDA ST	90012	14	132A215    65	5409023941	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			05/20/2013 12:00:00 AM			PC Approved	05/20/2013 12:00:00 AM	ADDRESS	34.05494	-118.23752	Changes to previously approved set of plans. Plan check for energy and emergency lighting. Title 24 Energy only 2415 sq ft.  Union Station.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76922	14041-20000-14057	7645 N ROYER AVE	91304	12	186B097    75	2014034046	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			05/27/2014 12:00:00 AM	05/27/2014 12:00:00 AM		Permit Finaled	06/12/2014 12:00:00 AM	ADDRESS	34.20967	-118.62791	PV1.  Install 1.0 kW roof-mounted utility-interactive PV system.  Microinverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76923	16041-20000-19756	1377 N SERRANO AVE	90027	13	147A193   171	5544032016	[Q]CM-1	Central	Hollywood	East Hollywood		1911.10	Electrical	Electrical	Commercial			06/06/2016 12:00:00 AM	06/15/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.0965	-118.30717	Install (N) fire alarm system for (E) commercial 3-story building.  New FACP with (149) devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76924	12041-10000-26931	900 S BROADWAY	90015	14	127-5A209 247	5139002018	[Q]C2-4D-CDO	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			11/08/2012 12:00:00 AM			PC Approved	12/18/2012 12:00:00 AM	ADDRESS	34.04213	-118.25602	PLAN CHECK FOR ENERGY. TI TO EXISTING BUILDING. ADDING LIGHTS. 2836 SF. MARKET TO OPEN 24/7/365. EXISTING EMERGENCY LIGHTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76925	17041-20000-30501	6815 N CANOGA AVE	91303	3	183B105   939	2138011026	[Q]C1-1VL-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1345.20	Electrical	Electrical	Commercial			08/25/2017 12:00:00 AM			PC Approved	05/20/2024 12:00:00 AM	PIN	34.1940675	-118.59784166	[eplan] 4000A 480Y/277V 3ph-4w service, distribution, power, and lighting for new mixed use development.  Plan check for power and energy.  Approved plans under 17041-10002-30501.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76926	17041-10001-08781	1606 W SUNSET BLVD	90026	13	139-5A209 185	5404018002	[Q]C2-1VL-CDO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1975.00	Electrical	Electrical	Commercial			08/31/2018 12:00:00 AM			PC Approved	08/31/2018 12:00:00 AM	ADDRESS	34.07672	-118.25775	Change to approved set by modifying the lighting floor plan all changes under delta-2 only.(((CHANGE OF USE FROM JUICE BAR AND RETAIL TO MARKET AND RESTAURANT. OUTDOOR DINING AREA 4998SF. 800A SERVICE AND NEW ELECTRICAL WORK. BACK FEED 1 EXISTING SUBPANEL ND ASSOCIATED LOADS.  PC FOR POWER AND ENERGY. BUILDING PERMIT 16016-10000-18044)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76927	16041-20000-36999	515 S FLOWER ST 26th Floor	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/19/2016 12:00:00 AM	12/22/2016 12:00:00 AM		Permit Finaled	09/01/2017 12:00:00 AM	ADDRESS	34.05134	-118.25661	Plan check for Title 24 only. Project site is the 26th floor of an existing commercial building. Project scope is a tenant improvement to the entire floor. Total lighting area is 21,112 sq. ft.Note: Building application has been generated under 16016-10000-23806	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76928	17041-10000-07537	6502 N VAN NUYS BLVD	91401	6	180B149   597	2237014006	[Q]C2-1L-CDO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1281.02	Electrical	Electrical	Commercial			03/08/2017 12:00:00 AM	03/09/2017 12:00:00 AM		Permit Finaled	04/19/2017 12:00:00 AM	ADDRESS	34.18884	-118.44845	PC FOR ENERGY. REPLACE (E) HID LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL ARAE 21500 SQ FT. INDOOR+OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76929	12041-10000-31230	8232 N WHITE OAK AVE	91325	12	192B129   323	2201001032	(Q)C2-1VL, C2-1VL, P-1VL	South Valley	Reseda - West Van Nuys	Northridge South		1312.00	Electrical	Electrical	Commercial			12/31/2012 12:00:00 AM			PC Approved	02/26/2013 12:00:00 AM	ADDRESS	34.22023	-118.51841	"TENANT IMPROVEMENT FOR ""DOLLAR TREE""  RETAIL STORE.  LESS THAN 100 OCCUPANTS.  T24 FOR LIGHTING"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76930	15041-20000-42732	14118 W MAGNOLIA BLVD	91423	4	171B153   455	2248022039	C1-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			12/17/2015 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	02/18/2016 12:00:00 AM	ADDRESS	34.16467	-118.44058	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING (OFFICE SPACE). SCOPE INCLUDES NEW LIGHTING.  TOTAL AFFECTED AREA IS 2759 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76931	17041-20001-41502	737 S LONGWOOD AVE	90005	4	132B185    95	5507029007	RS-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2017 12:00:00 AM			PC Approved	12/06/2017 12:00:00 AM	ADDRESS	34.06091	-118.33708	EXPEDITED PER APPLICANTS REQUEST. PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 10.080 KW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76932	18041-20000-04915	5122 W MAPLEWOOD AVE	90004	4	141B189   932	5522016017	R3-1	Central	Wilshire	Greater Wilshire		1924.10	Electrical	Electrical	Apartment			02/09/2018 12:00:00 AM	08/06/2018 12:00:00 AM		Permit Finaled	04/29/2020 12:00:00 AM	ADDRESS	34.08019	-118.31434	Plan check for power and energy. Project site is a 5-story, 24-unit apartment building. Work includes a new 1,200-amp service and a total lighting area of 14, 264 sq. ft.Note: Building application has been generated under 18010-10000-00367	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76933	15041-10000-01431	11755 W WILSHIRE BLVD 10TH FL	90049	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			01/16/2015 12:00:00 AM	01/23/2015 12:00:00 AM		Permit Finaled	04/28/2015 12:00:00 AM	PIN	34.04869377	-118.46238681	TI of 10th floor office space. high rise. Total area = 10420 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76934	15041-10001-31181	13439 W CHANDLER BLVD	91401	4	171B157    52	2344010018	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1245.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2015 12:00:00 AM			PC Approved	11/13/2015 12:00:00 AM	ADDRESS	34.16871	-118.4258	EXPEDITE PER CUSTOMER REQUESTInstallation of 16KW PHOTOVOLTAIC SYSTEM ON THE ROOF OF SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76935	14041-20000-27748	8075 W 3RD ST	90048	5	138B177   725	5511022032	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			10/07/2014 12:00:00 AM			PC Approved	10/07/2014 12:00:00 AM	ADDRESS	34.07225	-118.36564	Plan check for energy only. Inspector requested Title-24 plans. 4 new recessed lights installed as part of new metal canopy. Electrical permit pulled under #14041-30000-26809	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76936	10041-10001-10376	10250 W SANTA MONICA BLVD # 112	90025	5	132B161   512	4319003064	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/21/2010 12:00:00 AM			PC Approved	09/27/2010 12:00:00 AM	PIN	34.0586034	-118.41904766	Revision to the priviously approved plan. Plan check for T24 and emergency.  (((((((((((((((((TENANT IMPROVEMENT IN A RETAIL STORE. PLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT)))))))))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76937	12041-10000-21146	4550 W PICO BLVD C309	90019	10	129B185  1008	5083033016	C4-1-O, [Q]C2-1-O	Central	Wilshire	Mid City		2172.00, 2182.20	Electrical	Electrical	Commercial			09/06/2012 12:00:00 AM	12/21/2012 12:00:00 AM		Permit Finaled	02/27/2013 12:00:00 AM	ADDRESS	34.04842	-118.33486	Plan check power & energy for first time tenant. New dental office Suite #C-309. New panels, ckts, and equipments.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76938	18041-10000-28252	21111 W PLUMMER ST	91311	12	201B105   225	2746006027	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			07/27/2018 12:00:00 AM	07/27/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.24286	-118.594	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76939	19041-20001-48950	19268 W NORTHFLEET WAY	91356	3	162B117   230	2177046009	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2019 12:00:00 AM			PC Approved	12/12/2019 12:00:00 AM	ADDRESS	34.13982	-118.55312	PV1 PLAN CHECK FOR NEW PV SYSTEM. SYSTEM SIZE IS 17.6 KW DC/15.2 KW AC. SCOPE OF WORK CONSISTS OF (55) PV MODULES WITH AND (2) 7.6 KW INVERTER	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76940	13041-20000-02755	254 S HOPE ST	90012	14	130-5A211   4	5151015015	C2-4D, R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			02/04/2013 12:00:00 AM			PC Approved	02/04/2013 12:00:00 AM	ADDRESS	34.05377	-118.25196	Change to lighting in an existing bakery/restaurant.  Occupancy load is less than 99 and load is less than 400 amps per applicant..  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76941	14041-10000-33056	1307 W SEPULVEDA BLVD # A	90501	15	042B197   227	7347018089	M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			11/26/2014 12:00:00 AM			Reviewed by Supervisor	12/23/2014 12:00:00 AM	ADDRESS	33.8138	-118.2996	FULL PLAN CHECK FOR COFFEE SHOP. TWO NEW PANELS. FIRST TIME TENANT. TOTAL AREA 1561 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76942	14041-10000-10647	7326 N LAUREL CANYON BLVD	91605	2	186B165   550	2317015009	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1224.10	Electrical	Electrical	Commercial			04/23/2014 12:00:00 AM	04/23/2014 12:00:00 AM		Permit Expired	05/17/2016 12:00:00 AM	ADDRESS	34.2039	-118.39608	T24 ONLY, REMOVING HID  FIXTURES AND REPLACING WITH NEW FLORESCENT ONE. TOTAL AREA 904 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76943	16041-10000-23148	9834 W SAN CIR	90210	5	150B157   183	4384021020	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2016 12:00:00 AM	08/10/2016 12:00:00 AM		Permit Finaled	09/08/2016 12:00:00 AM	ADDRESS	34.10552	-118.42534	$0 permit fee due to senate bill 1222 from 2012PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 11.4KWac.(42)MODULES-LG 365N2W-B3(42)OPTIMIZERS-SOLAREDGE P400W(1)INVERTER-SOLAREDGE SE11400A-US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76944	16041-10000-35682	8110 N REMMET AVE 4-5	91304	3	189B105    88	2110020010	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.05	Electrical	Electrical	Commercial			10/07/2016 12:00:00 AM	05/16/2017 12:00:00 AM		Permit Finaled	07/28/2017 12:00:00 AM	ADDRESS	34.21728	-118.60015	PC FOR TITLE 24 ENERGY ONLY!SCOPE INCLUDES INSTATLLION OF NEW LIGHTING AND RECEPTACLES.TOTAL  AREA 2470 SQ.FT. FOR UNITS 4 & 5.REFER TO  BLDG APP # 16016-30000-19783	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76945	16041-10000-06870	4929 W WILSHIRE BLVD ste 800	90010	4	135B185   568	5507018032	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/26/2016 12:00:00 AM	02/26/2016 12:00:00 AM		Permit Finaled	05/05/2016 12:00:00 AM	ADDRESS	34.06228	-118.33794	PC for energy only to a commercial site (suite #800). Adding new lighting and power. Total sqft = 7230	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76946	11041-20001-23123	4331 N NATOMA AVE	91364	3	166-5A111 102	2174010017	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center	YES	1380.00	Electrical	Electrical	1 or 2 Family Dwelling			11/14/2011 12:00:00 AM			PC Approved	11/14/2011 12:00:00 AM	ADDRESS	34.14919	-118.58018	Revision to approved plans. Remove combiner box on roof and 60A DC disconnect and connect to inverter 6 terminal inputs.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76947	16041-10000-08945	1906 W 36TH PL	90018	8	120B189  1443	5042020019	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	1 or 2 Family Dwelling			03/15/2016 12:00:00 AM	03/15/2016 12:00:00 AM		Permit Expired	04/13/2018 12:00:00 AM	ADDRESS	34.02176	-118.31429	PV1, rooftop solar installation 3kW   (8) Kyocera #KD255GX-LFB3      (1) PVI-3.0-OUTD-S        (1) 125A load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76948	19041-20000-32084	20400 W PLUMMER ST	91311	12	198B109    56	2748022073	MR2-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03	Electrical	Electrical	Commercial			08/16/2019 12:00:00 AM			PC Info Complete	08/16/2019 12:00:00 AM	ADDRESS	34.24253	-118.57768	New distribution and industrial equipment for commercial manufacturing facility.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76949	14041-10000-35329	700 W 7TH ST	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/22/2014 12:00:00 AM	12/01/2015 12:00:00 AM		Permit Finaled	11/14/2016 12:00:00 AM	ADDRESS	34.04797	-118.25815	TI IN CORRIDORS,STAIRCASE AND TENANT AREA ON LEVELS GND, A, AND BPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76950	15041-20000-07173	8521 N FALLBROOK AVE	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/31/2015 12:00:00 AM		Permit Finaled	06/23/2015 12:00:00 AM	ADDRESS	34.22368	-118.62797	Plan check for power and energy for T.I. office building. Total area: 29869 sq ft. Relocate 4 panels and add 5 new panels	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76951	15041-10000-09380	200 S LA BREA AVE	90036	5	138B181  1265	5513023004	C2-1LD, [Q]C2-1	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	Commercial			03/31/2015 12:00:00 AM	06/16/2015 12:00:00 AM		Permit Finaled	10/23/2015 12:00:00 AM	ADDRESS	34.07067	-118.34383	Interior tenant improvement at existing retail store( PETCO)PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76952	15041-10004-26434	1101 S FLOWER ST	90015	14	127-5A207 330	5138015***	LASED	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			01/06/2017 12:00:00 AM	09/14/2018 12:00:00 AM		Permit Expired	02/02/2024 12:00:00 AM	ADDRESS	34.04284	-118.26457	Full plan check to a change to approved set  for owner build out on tower 2, 3 and the podium building . All (3) buildings are high rise building, and under (1) plan check application number.  each of the building will have its own different permit  number.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76953	18041-10000-35652	2201 E WASHINGTON BLVD	90021	14	118-5A215   6	5167019900	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			09/18/2018 12:00:00 AM			PC Info Complete	09/18/2018 12:00:00 AM	ADDRESS	34.01911	-118.23383	Pc for T24 only for new lights in mezanine area and corridor.  Total affected area is 1252 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76954	18041-10000-03424	3500 S KERCKHOFF AVE	90731	15	006B197   577	7467008025	R1-1XL	Harbor	San Pedro	Coastal San Pedro		2976.02	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2018 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	02/09/2018 12:00:00 AM	ADDRESS	33.7117	-118.2896	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER AND OPTIMIZERS. (11) MODULES AND (1) 3.8KWAC INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76955	19041-10000-53901	1149 S HILL ST SUITE 360	90015	14	126A207   141	5139019038	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/31/2019 12:00:00 AM	03/05/2020 12:00:00 AM		Permit Finaled	07/27/2020 12:00:00 AM	ADDRESS	34.03926	-118.26099	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN EXISTING SPACE. TOTAL AFFECTED AREA IS 6508 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76956	16041-20000-10802	6922 W HOLLYWOOD BLVD 9TH FLOOR	90028	13	147B181   197	5548006011	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			03/29/2016 12:00:00 AM	09/15/2016 12:00:00 AM		Permit Finaled	11/21/2016 12:00:00 AM	ADDRESS	34.10137	-118.34103	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR RESTROOMS. 9TH FLOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76957	17041-10000-36625	2024 W 62ND ST	90047	8	105B189  1020	6001020015	M1-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2372.02	Electrical	Electrical	Commercial			10/11/2017 12:00:00 AM	12/27/2017 12:00:00 AM		Permit Finaled	09/19/2023 12:00:00 AM	ADDRESS	33.98325	-118.31436	NEW FOR ROOF MOUNTED PV SYSTEM ON COMMERCIAL BUILDING. SYSTEM SIZE 20KWAC. SCOPE INCLUDES 66 PANELS WITH SINGLE INVERTER.  THIS IS SYSTEM #3 OUT OF MULTIPLE SYSTEMS INSTALLED ON THE SAME ROOF. OTHER SYSTEMS ARE UNDER SEPARATE PERMIT.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76958	16041-10000-20452	1514 W 94TH ST	90047	8	094-5A195 405	6055005045	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2380.00	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2016 12:00:00 AM	06/10/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	33.95101	-118.30315	PV1, rooftop solar installation, 3.0 kW Ac system,    (11) Solar city standrad module    (1) PVI-3.0-OUTD	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76959	18041-30000-04637	11616 W BURBANK BLVD	91601	2	174B169   875	2350001019	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Apartment			02/08/2018 12:00:00 AM	05/10/2018 12:00:00 AM		Permit Finaled	07/25/2019 12:00:00 AM	ADDRESS	34.17192	-118.38543	Plan check for power and energy for new appartment 21 units 4 story. Total area: 27,000 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76960	12041-10000-08099	6141 N KENTLAND AVE	91367	3	177B097   315	2039029014	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2012 12:00:00 AM	04/10/2012 12:00:00 AM		Permit Finaled	05/29/2012 12:00:00 AM	ADDRESS	34.18255	-118.6181	New 11.44kw rooftop photovoltaic system for an existing single family residence.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76961	17041-20000-10412	7737 N DEERING AVE	91304	3	189B105   571	2109030043	MR1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1342.01	Electrical	Electrical	Commercial			03/31/2017 12:00:00 AM	03/31/2017 12:00:00 AM		Issued	03/31/2017 12:00:00 AM	ADDRESS	34.21094	-118.59678	Service upgrade 600 A 120/240V 3ph/4w for light industrial building.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76962	18041-10000-17692	1030 N SWARTHMORE AVE #3-106	90272	11	129B125   839	4423016023	[T][Q]C2-1VL	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			05/14/2018 12:00:00 AM	07/12/2018 12:00:00 AM		Permit Finaled	02/05/2019 12:00:00 AM	ADDRESS	34.04776	-118.52525	Full plan check for a 1st time tenant T.I located inside a mall area .  Scope includes new lighting and equipmnet.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76963	15041-20000-22716	3481 S SAWTELLE BLVD	90066	11	117B157   355	4249026290	OS-1XL	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.01	Electrical	Electrical	Commercial			07/16/2015 12:00:00 AM			PC Info Complete	08/03/2015 12:00:00 AM	ADDRESS	34.01768	-118.42494	Plan check for power only. Project site is an existing school. Project scope is the installation of (1) 150 kVA transformer, (1) 200-amp panel, and associated loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76964	13041-20000-12428	5750 W WILSHIRE BLVD #600	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			05/14/2013 12:00:00 AM			PC Approved	05/14/2013 12:00:00 AM	ADDRESS	34.06227	-118.3542	RENOVATION OF INTERIOR SPACES. WORK DONE IN SUITE 600. NEW CONNECTED LOAD < 400A. NEW LIGHTING AND EMERGY CIRCUIT. PLAN CHECK FOR T24 ENERGY ONLY. PERMIT TO BE ISSUED BY PC STAFF ONLY. TOTAL AREA 5260 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76965	15041-10000-33436	4929-4931 N LANKERSHIM BLVD	91601	2	168B173    66	2353017001	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			10/08/2015 12:00:00 AM			PC Approved	10/08/2015 12:00:00 AM	ADDRESS	34.1605	-118.3723	PLAN CHECK FOR ENERGY ONLY FOR NEW RESTAURANT. PERMIT HAS BEEN PULLED UNDER APPLICATION: 15041-30000-30876. PLAN CHECK ONLY APPLCIATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76966	18041-10000-41645	7875 N WILLIS AVE	91402	6	189B149   483	2209041029	M1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			10/30/2018 12:00:00 AM	10/31/2018 12:00:00 AM		Permit Finaled	01/04/2019 12:00:00 AM	ADDRESS	34.21426	-118.45542	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76967	11041-10000-10158	1741 N CHEROKEE AVE Garage	90028	13	148-5A185  32	5547009014	[Q]R5-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			05/18/2011 12:00:00 AM			PC Approved	06/24/2011 12:00:00 AM	ADDRESS	34.10281	-118.33488	T24 for new garage building.  On same lot as existing office building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76968	19041-20001-06344	6067 W WILSHIRE BLVD pv3	90036	4	135B177   428	5508017004	[Q]C2-2-CDO-SN	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			02/21/2019 12:00:00 AM			PC Approved	03/12/2019 12:00:00 AM	ADDRESS	34.0631	-118.36086	expeditepv3install roof mounted pv system sized 63KW AC interconnected with msp.  (202) modules sunpower 360W	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76969	18041-20001-21108	23052 W HATTERAS ST	91367	3	174B097   190	2041016028	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1373.01	Electrical	Electrical	1 or 2 Family Dwelling			06/07/2018 12:00:00 AM			PC Approved	07/12/2018 12:00:00 AM	ADDRESS	34.17538	-118.62942	Expedited plan check fee.PV1.  Installation of a roof mounted grid tied PV system.  PV system is partially installed on open trellis cover.  (35) modules with (2) 5 kW rated string inverters.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76970	19041-10000-20519	6510 W FOREST LAWN DR	90068	4	165B185   205	5581004021	(T)(Q)C1.5-1	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			05/30/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	07/12/2019 12:00:00 AM	ADDRESS	34.14678	-118.33255	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 Only	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76971	14041-10000-27900	14170 W CHANDLER BLVD	91401	4	171B153   147	2248018024	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1285.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2014 12:00:00 AM	11/05/2014 12:00:00 AM		Permit Finaled	11/25/2014 12:00:00 AM	ADDRESS	34.16821	-118.44189	PV1 miroinverter 7.7KW roof mounted system including (69) modules, (69) Enphase M250 microinverters, and (2) load center.$0 permit fee per State Senate Bill SB-1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76972	16041-20000-28598	6033 W CENTURY BLVD 8th Floor-Restrooms	90045	11	090B169    17	4124030901	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			08/11/2016 12:00:00 AM	08/11/2016 12:00:00 AM		Permit Finaled	12/05/2016 12:00:00 AM	ADDRESS	33.94572	-118.38954	Plan check for energy only. Remodel bathrooms on 8th floor. New lighting. 406sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76973	17041-20000-06988	17433 W FLANDERS ST	91344	12	213B129   208	2607009032	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/03/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	03/23/2017 12:00:00 AM	ADDRESS	34.28026	-118.51336	Plan check for a PV1 roof-mounted PV system. System size is 9 kWac and consists of (2) inverters, (40) modules, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
76974	18041-20000-25427	21215 W BURBANK BLVD Suite 630	91367	3	174B105    88	2149019019	(WC)COMMERCE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1371.04	Electrical	Electrical	Commercial			07/09/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Issued	07/09/2018 12:00:00 AM	ADDRESS	34.17353	-118.59268	Plan check for Title 24 only. Project site is a suite on the 6th floor of a commercial building. Project scope is a tenant improvement. Total lighting area = 2,387 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76975	17041-10000-08076	1121 S WESTERN AVE	90006	10	129B193   752	5080003041	C2-1	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			03/14/2017 12:00:00 AM	03/14/2017 12:00:00 AM		Permit Finaled	08/09/2017 12:00:00 AM	ADDRESS	34.0501	-118.30928	T-24, PC FOR ENERGY ONLY. REPLACING HID FIXTURES WITH NEW LED FIXTURES FOR OUTDOOR USE. TOTAL AFFECTED AREA IS 23200 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76976	17041-20000-09915	8635 W 3RD ST 866-WEST	90048	5	138B169   431	4334006015	C1-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			03/28/2017 12:00:00 AM	05/02/2017 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	34.07373	-118.38073	PLANCHECK FOR POWER AND ENERGY. TI FOR MEDICAL OFFICE STE 866 WITHIN EXISTING WEST TOWER BUILDING; 8TH FLOOR AND TOTAL 2289 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76977	18041-10000-23312	15100 W ERWIN ST	91411	6	177B145   361	2242025901	OS-1XL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			06/22/2018 12:00:00 AM	06/22/2018 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.18281	-118.46212	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACEMENT WITH NEW LED FIXTURES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76978	16041-10001-24674	16717 W ALGINET PL	91436	5	159B137   215	2287011032	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			11/17/2016 12:00:00 AM	12/07/2016 12:00:00 AM		Permit Finaled	01/17/2017 12:00:00 AM	ADDRESS	34.13379	-118.4967	PC FOR A NEW PV SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.5KWac.(38)MODULES-CANADIAN SOLAR CS6K-275M(38)MICROINVERTERS-ENPHASE M250-60-2LL-S22(1)100A SUBPANEL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76979	15041-10000-18543	8500 W BEVERLY BLVD STE 727	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			06/15/2015 12:00:00 AM	07/13/2015 12:00:00 AM		Permit Finaled	09/10/2015 12:00:00 AM	ADDRESS	34.07587	-118.37754	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.  TOTAL SQUARE FOOTAGE 1400. SCOPE OF WORK TO BE PERFORMED IN SUITE 727	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76980	12041-10000-13078	13603 W MARINA POINTE DR	90292	11	105B153    74	4229003066	C4(OX)-2D	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Apartment			06/06/2012 12:00:00 AM	11/14/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	33.98559	-118.44433	Plan check T24 outdoor lighting for court yard areas (Building A, Building B, Building C, and Building D). Site located in methane zone. No installation in hazardous area.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76981	19041-10000-08121	1850 N CHEROKEE AVE	90028	13	150A185   278	5547004021	(T)(Q)R4-2	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Apartment			03/07/2019 12:00:00 AM	03/07/2019 12:00:00 AM		Permit Finaled	01/14/2020 12:00:00 AM	ADDRESS	34.10481	-118.33464	NEW FIRE ALARM SYSTEM WITH 44 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76982	18041-20000-06188	6376 W 80TH PL	90045	11	099B165   705	4108026031	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			02/20/2018 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	04/27/2018 12:00:00 AM	ADDRESS	33.96609	-118.39883	PLAN CHECK FOR PV SYSTEM(7.6KW) WITH BATTERY BACK UP SYSTEM - SYSTEM CONSIST OF 12 MODULES WITH P320 POWER OPTIMIZERS, CENTRAL INVERTER (SOLAREDGE SE7600-US), BATTERY BACKUP (LG CHEM RESU10H) AND AUTO TRANSFORMER (SEAUTO-TX-5000)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76983	13041-10000-01715	1320 S COMSTOCK AVE	90024	5	135B157   233	4327024009	R1-1	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2013 12:00:00 AM	02/22/2013 12:00:00 AM		Permit Finaled	10/04/2013 12:00:00 AM	ADDRESS	34.06593	-118.42512	photovoltaic system for two story single family dwelling. total number of modules is 20. 5.045 kw system. utilize microinverter enphase m215-60-2ll-s22. solar panel - mitsubishi pv-mlu255hc	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76984	14041-20001-14214	5222 N ETHEL AVE	91423	4	171B161  1218	2345018071	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			05/28/2014 12:00:00 AM			PC Approved	06/16/2014 12:00:00 AM	PIN	34.1654321	-118.41798238	Fee for expedite only.*****Roof mounted PV system with Optimizers and tranformerless inverter.  PV system size 10KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76985	11041-20000-13664	14800 W VENTURA BLVD	91403	5	166-5A149  44	2276003***	C2-1L, P-1, [Q]P-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.01	Electrical	Electrical	Commercial			06/30/2011 12:00:00 AM	09/08/2011 12:00:00 AM		Permit Finaled	03/13/2012 12:00:00 AM	ADDRESS	34.15186	-118.45547	Installation of AT&T medium voltage equipment and 480V equipment on the 8th floor. Phase IB	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76986	16041-20000-45352	7043 N MAYNARD AVE	91307	12	183B097   294	2024020019	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.22	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM	01/10/2017 12:00:00 AM		Permit Finaled	02/16/2017 12:00:00 AM	ADDRESS	34.19879	-118.62252	Plan check for installation of a solar pv array, roof-mounted on a SFD. Interconnect with a 225A MSP.17.92kW ungrounded system. (56) 320W AC modules.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
76987	15041-10000-28426	9074 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			08/28/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	06/27/2016 12:00:00 AM	ADDRESS	34.23473	-118.55335	TI TO AN EXISTING SINGLE STORY COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 1300	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76988	13041-10000-10927	7115 N MILWOOD AVE	91303	3	183B105   365	2112028022	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Canoga Park		1345.20	Electrical	Electrical	Apartment			04/29/2013 12:00:00 AM	04/29/2013 12:00:00 AM		Permit Finaled	06/11/2013 12:00:00 AM	ADDRESS	34.19968	-118.5944	Title 24 plan check for office TI in apartment building.  2-story, 200 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76989	17041-10000-18093	125 S LOMA DR	90026	13	135A207   339	5153013038	R3-1	Central	Westlake	Westlake North		2083.02	Electrical	Electrical	Commercial			05/31/2017 12:00:00 AM	05/31/2017 12:00:00 AM		Issued	05/31/2017 12:00:00 AM	ADDRESS	34.06273	-118.26372	Title 24 plan check.  Remove HID fixtures and replace with LED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76990	16041-10001-44122	22445 W MICHALE ST	91304	12	192B101    67	2004017016	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.32	Electrical	Electrical	1 or 2 Family Dwelling			12/15/2016 12:00:00 AM			PC Approved	12/28/2016 12:00:00 AM	ADDRESS	34.2259	-118.61587	12/15/2016 Expedite per applicant request{{{{{Plan check for PV roof mounted system. System size: 11.52kW with 36 modules LG LG320N1C(320W) and 36 microinverters Enphase S280-60-LL_2-US. Connect to 225 A panel with 200A Main Breaker.}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76991	12041-10000-01925	990 W 190TH ST #500	90502	15	060B197  1712	7351031027	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/26/2012 12:00:00 AM			PC Info Complete	01/26/2012 12:00:00 AM	ADDRESS	33.85813	-118.29505	T.I. to a high rise building on 5th floor.  Install general/emergency  lighting fixtures.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76992	18041-10000-27166	16601 W RINALDI ST	91344	12	213B137   476	2610014008	A1-1	North Valley	Granada Hills - Knollwood	Granada Hills North		1066.46	Electrical	Electrical	Commercial			07/20/2018 12:00:00 AM	07/20/2018 12:00:00 AM		Permit Finaled	08/17/2018 12:00:00 AM	ADDRESS	34.27948	-118.49358	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76993	14041-20000-04471	12500 W BRANFORD ST	91352	6	201B165   107	2629001006	(Q)M2-EZ1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1212.10	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	03/03/2015 12:00:00 AM	ADDRESS	34.24638	-118.40551	FedEx warehouse building expansion.  Add new panels, transformer, and branch circuits.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76994	16041-10002-18613	1530 S OCEAN FRONT WALK	90291	11	106-5A143  65	4226001903	OS-1XL-O	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			10/24/2016 12:00:00 AM	10/25/2016 12:00:00 AM		Issued	10/25/2016 12:00:00 AM	ADDRESS	33.98684	-118.47372	10/24/16Changes to an approved set of plans. All changes are made under delta 2. Changes include relocating service on the site plan, revising fault current, and adding one new 200A panel. (((((Amandment to an approved set of plan, upgrading service and distribution equipment from 1000A to 1200A. Plan check only. Permit should be pulled under the original application.cam lock outlet changed to 1000A. PC only no permit under this application{{{AEXISTING OCEAN FRONT. NEW SERVICE FOR STREET VENDORS AND LANDSCAPE LIGHITNG. NEW PANEL FOR FUTURE USE. NO TITLE T24 - EXEMPT. PC FOR POWER ONLY. 1000A SERVICE}}}	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
76995	10041-10000-04310	3111 S VIA DOLCE	90292	11	105A147   253		C2-1	West Los Angeles	Venice	Venice		2742.00	Electrical	Electrical	Apartment			03/10/2010 12:00:00 AM	04/12/2010 12:00:00 AM		Permit Finaled	04/28/2010 12:00:00 AM	ADDRESS	33.98056	-118.46348	T.I. for a high rise building 1st floor.  Install general and emergency lighting in interior lobby, entrance, and exterior driveway.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76996	19041-20000-50744	850 W 42ND ST	90037	9	114B197   746	5019005021	R3-1	South Los Angeles	South Los Angeles	Voices		2317.10	Electrical	Electrical	Apartment			12/12/2019 12:00:00 AM			PC Info Complete	06/22/2023 12:00:00 AM	ADDRESS	34.00726	-118.28906	FULL PLAN CHECK FOR NEW 1000A SERVICE, (1) 1000A MAIN PANEL, (18) 0-200A SUB PANELS, (1) 5.1-20 HP-KVA EQUIPMENT, (35) 3.1-5 HP-KVA EQUIPMENTS, (17) SMOKE DETECTORS, AND (240) BRANCH CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
76997	14041-20000-21491	18321 W VENTURA BLVD SUITE #100	91356	3	171B125    82	2160009005	C2-1L, PB-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			08/08/2014 12:00:00 AM	11/03/2014 12:00:00 AM		Permit Finaled	02/04/2015 12:00:00 AM	ADDRESS	34.16715	-118.5315	CHG OF USE TO BANK FROM OFFICE & TI. pc for t24 energy only. new lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76998	17041-20000-37788	11755 W WILSHIRE BLVD ste 1625	90025	11	129B145   683	4265010901	[Q]C4-2-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Commercial			10/19/2017 12:00:00 AM	10/24/2017 12:00:00 AM		Permit Finaled	11/17/2017 12:00:00 AM	ADDRESS	34.04856	-118.46231	Plan check for energy only. TI to office suite 1625 in high rise building. New lighting (incl. emergency) - 1,111sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
76999	16041-10006-14985	6151 W CENTURY BLVD	90045	11	090B165     8	4124030029	C2-2	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Approved	09/26/2017 12:00:00 AM	ADDRESS	33.9457	-118.39308	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 10 - ADDED FUSE SWITCH AND UPDATED SINGLE LINE TO MATCH FIELD CONDITIONS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77000	12041-10001-24318	448 S HILL ST 1301-1318	90013	14	129A211    46	5149026004	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/07/2013 12:00:00 AM			PC Approved	06/07/2013 12:00:00 AM	ADDRESS	34.04896	-118.25139	Tenant space owner of 1301 desires to use space for storage, corresponding reduction in scope for project under 12041-20000-24318.  T24 plan check only.Original Work Description: Plan check for energy and emergency lighting. Office space. 13th floor, 1301 and 1318. 2764 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77001	15041-10000-19296	7800 N AIRPORT BUSINESS PARK WAY	91406	6	189B137   126	2205009095	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			06/19/2015 12:00:00 AM	06/19/2015 12:00:00 AM		Permit Finaled	07/07/2015 12:00:00 AM	ADDRESS	34.21143	-118.49524	T-24 ONLY, REMOVING HID LIGHT FIXTURES WITH LED FIXTURES. TOTAL SQ. FT. 22784.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77002	11041-20000-05128	13626 W VANOWEN ST	91401	2	180B157    13	2329001038	[Q]C2-1VL, [Q]P-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	03/21/2011 12:00:00 AM		Permit Finaled	10/10/2014 12:00:00 AM	PIN	34.19364993	-118.43028174	Install general lighting for laundrymat.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77003	17041-20001-05773	10404 N SEPULVEDA BLVD	91345	7	204B145   113	2649019032	(T)(Q)C2-1, R1-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			11/02/2017 12:00:00 AM			PC Approved	11/02/2017 12:00:00 AM	PIN	34.25931857	-118.46630746	11/02/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta 2. Changes were made to the home-runs and EM lighting wiring.*****Previous Work Description*****TENANT IMPROVMENT TO RETAIL SPACE (T-MOBILE).  PLAN CHECK FOR ENERGY.Note: Building permit has been pulled under 17016-20000-03987 with an address correction under 17016-20001-03987.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77004	18041-10000-20729	17819 W MERRIDY ST	91325	12	204B129   458	2734006009	(Q)R3-1	North Valley	Northridge	Northridge East		1113.02	Electrical	Electrical	Commercial			06/05/2018 12:00:00 AM	06/05/2018 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.25233	-118.52224	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77005	10041-10000-14090	1326 S ABBOT KINNEY BLVD	90291	11	108B145  1321	4238004009	C2-1-O-CA	West Los Angeles	Venice	Venice		2735.02	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			PC Info Complete	07/23/2010 12:00:00 AM	ADDRESS	33.99077	-118.46723	T.I. for existing retail building.  Install indoor/outdoor general and emergency lights.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77006	15041-20002-13315	6316 N TOPANGA CANYON BLVD B-2110	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			01/06/2016 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.18578	-118.60514	[[[1/6/15 CHANGES TO APPROVED SET OF PLANS. DELTA 6 CHANGES ONLY. CHANGES TO LOCATION OF TRANSFORMER AND ADDITION OF SHUNT TRIP FOR EMERGENCY LIGHTING]]]]]TI to new commercial building (fitness studio). Plan check for power and energy. Adding new lighting including emergency. Total sqft. 5,442.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77007	12041-20000-12405	337 N FAIRFAX AVE	90048	5	138B177   222	5527036017	C2-1VL	Central	Wilshire	Mid City West		1945.00	Electrical	Electrical	Commercial			05/30/2012 12:00:00 AM			PC Approved	05/30/2012 12:00:00 AM	PIN	34.0772296	-118.3617713	ENERGY PLAN CHECK RETAIL	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77008	19041-20000-53735	3740 S MCCLINTOCK AVE B16	90089	9	117B197     7	5039012027	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/30/2019 12:00:00 AM	04/27/2020 12:00:00 AM		Permit Finaled	08/04/2020 12:00:00 AM	ADDRESS	34.01972	-118.29033	Plan check for new lighting Title 24 Energy only. Total area: 477 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77009	19041-20000-53230	11616 W BURBANK BLVD	91601	2	174B169  1307	2350001097	[Q]R3-1	South Valley	North Hollywood - Valley Village	NoHo		1252.00	Electrical	Electrical	Apartment			12/24/2019 12:00:00 AM	02/14/2020 12:00:00 AM		Permit Finaled	03/27/2020 12:00:00 AM	ADDRESS	34.17192	-118.38543	PV2, ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTER AND POWER OPTIMIZERS. (22) MODULES WITH OPTIMIZERS AND (1) INVERTER. TOTAL SYSTEM SIZE IS 8.14 KW DC/9 KW AC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77010	19041-10000-23057	401 S VERMONT AVE #6	90020	10	135B197   497	5502009020	C2-1	Central	Wilshire	Wilshire Center-Koreatown		2119.21	Electrical	Electrical	Commercial			06/17/2019 12:00:00 AM	06/19/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.06699	-118.29189	Energy plan check for a tea store T.I. Scope includes new lighting and equipment with a total lighting area of 1011-SQ FT.Note. portion of permit fee is paid under 19041-10000-21180.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77011	18041-20000-17488	6600 N TOPANGA CANYON BLVD	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			05/11/2018 12:00:00 AM			Corrections Issued	05/11/2018 12:00:00 AM	ADDRESS	34.19008	-118.60565	Plan check for power only. Project site is an existing commercial building. Project scope is the addition of a 1,000 Amp rated MCB to an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77012	16041-10001-06798	10740 W STRATHERN ST	91352	2	189B177   968	2409007035	R1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1221.21	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM			PC Approved	04/14/2016 12:00:00 AM	PIN	34.2154559	-118.36552892	04/14/16Changes to an approved set of plans. Changes include changing inverter manufacturer from Power-One PVI-3.8-outd-S-US-A to SMA America SB3800TL-US-S22. System size still remains 3.8kWac for the PV system. Note: Permit Pulled under PCIS#16041-10000-06798((((PV 1 roof mounted solar system installation to a single family home. Central Inverter rating : 3.8 kw, (13) modules.(13)Modules-Sunpower SPR-327NE-WHT-D(1)Inverter-Power One PV-3.8-OUTD-US	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77013	15041-20000-07509	6255 W SUNSET BLVD STE 1110	90028	13	147A189    22	5546026031	C4-2D-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	08/12/2015 12:00:00 AM	ADDRESS	34.09815	-118.32564	Plan check for Title 24 only. Project scope is a TI to an existing office space. Total lighting area = 735 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77014	19041-10001-21474	13255 W PONDEROSA DR	90049	11	138B133    47	4492007018	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2019 12:00:00 AM			PC Approved	07/12/2019 12:00:00 AM	ADDRESS	34.07795	-118.50355	EXPEDITE PER APPLICANT REQUEST ((PV1. NEW ROOFTOP SOLAR SYSTEM WITH ENERGY STORAGE. SYSTEM CONSIST OF 18 AC MODULES (SUNPOWER SPR 360) AND 2 TESLA POWERWALL BATTERIES (13.5KW). SCOPE INCLUDES NEW 125A COMBINER BOX AND 125A LOAD CENTER. SYSTEM SIZE IS 5.67KWac.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77015	18041-10000-16351	1501 N STRADELLA ROAD	90077	5	147B149   262	4377036001	RE15-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	Yes	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2018 12:00:00 AM	05/29/2018 12:00:00 AM		Permit Finaled	07/02/2018 12:00:00 AM	ADDRESS	34.09982	-118.45843	PLAN CHECK FOR ROOF MOUNTED PV SYSTEM FOR 12KVA SYSTEM INCLUDING 2 INVERTERS(SMA SB 6.0-US) AND 29 SUNCECO SEP-310 310W POLY AND 11 SUNCECO SEP-260 260W MODULES.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77016	15041-20000-19897	2100 W NORWALK AVE	90041	14	160-5A221 382	5685017001	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1816.00	Electrical	Electrical	1 or 2 Family Dwelling			06/24/2015 12:00:00 AM	06/24/2015 12:00:00 AM		Permit Finaled	07/18/2015 12:00:00 AM	ADDRESS	34.13228	-118.21391	PV1 SFD. TOTAL SYSTEM SIZE 4.5KW AC USING MICROINVERTER SYSTEM. USING NONSTANDARD PLAN. TOTAL OF 21 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77017	18041-10000-24923	11501 W SANTA MONICA BLVD	90025	11	129B149   576	4261002021	C2-1VL	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2673.00	Electrical	Electrical	Commercial			07/03/2018 12:00:00 AM	10/25/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	34.0456	-118.45244	PC FOR ENERGY ONLY, EXISTING BANK 6811 SF  TI AREA; SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 4456.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77018	15041-10000-07131	3003 S LA SALLE AVE	90018	8	120B193   429	5053016032	R1-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2221.00	Electrical	Electrical	1 or 2 Family Dwelling			03/11/2015 12:00:00 AM	05/20/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.02708	-118.30549	PV1, INSTALL 3 KW DC ROOF-MOUNTED SOLAR ARRAY ON 4 UNITS DWELLING. INTERCONNECT WITH MAIN SERVICE PANEL. (10) MODULES: KYOCERA KU2606XPA(1) INVERTER: ABB PV1-3.0-OUTD-S-US-Z-A	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77019	17041-10000-34500	15518 W VINCENNES ST	91343	7	198B145   128	2656017005	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills East		1172.01	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2017 12:00:00 AM	09/27/2017 12:00:00 AM		Permit Finaled	10/30/2017 12:00:00 AM	ADDRESS	34.24086	-118.47033	PLAN CHECK FOR ROOF MOUNTED PV-SYSTEM. SYSTEM SIZE = 6KVA. SYSTEM CONSIST OF 1 CENTRAL INVERTER(SOALAR EDGE SE6000A-US) WITH 21 MODULES AND 21 POWER OPTIMIZERS(P320)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77020	10041-10000-13934	3220-3230 N NORTH BROADWAY	90031	1	138A225    55	5208010003	[Q]C4-1XL-CDO	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1992.02, 1998.00	Electrical	Electrical	Commercial			07/20/2010 12:00:00 AM	07/20/2010 12:00:00 AM		Permit Finaled	08/11/2010 12:00:00 AM	ADDRESS	34.0736	-118.207	T24 lighting plan check for NEW  GATEWAY FOR AVCFA, includes sign and site lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77021	18041-10000-45150	11246 W VALLEY SPRING LANE	91602	2	165B173   726	2366016017	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			11/28/2018 12:00:00 AM	05/31/2019 12:00:00 AM		Permit Finaled	06/11/2019 12:00:00 AM	ADDRESS	34.14707	-118.37621	Permit fees are $0 do to  assembly bill 1414. New Roof Mounted 13.6KW AC PV1 system with (41) module and optimizer, (2) inverters interconnecting through a subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77022	12041-10000-15655	820 S SPRING ST	90014	14	127-5A211 243	5144016047	C2-4D	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Apartment			07/06/2012 12:00:00 AM			Not Ready to Issue	07/06/2012 12:00:00 AM	ADDRESS	34.04255	-118.25395	INSTALL A FIRE ALARM SYSTEM FOR THE FACILITY. 3 stories, 7 units appartment. permit already issued under12041-10000-12123.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77023	13041-10001-02394	5946 W 76TH ST	90045	11	102B169   464	4105004015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			07/05/2013 12:00:00 AM			Corrections Issued	07/05/2013 12:00:00 AM	ADDRESS	33.97205	-118.38757	Supplemental: Change of module from REC 245 PE to REC 250 PE.Original description: PHOTOVOLTAIC SYSTEM FOR A SINGLE FAMILY SINGLE STORY DWELLING. TOTAL SIZE 2.16KW, USING 10 MODULES. PANEL - REC 245 PE. MICROINVERTER ENPHASE M215-60-2LL-S22.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77024	14041-10003-21463	3335 S FIGUEROA ST STE O	90007	9	120A203   503	5123009042	(Q)C2-2D-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM	01/15/2015 12:00:00 AM		Permit Finaled	01/23/2015 12:00:00 AM	ADDRESS	34.02224	-118.28008	Plan check for power only for  suite O - no changes to energy. Changes clouded under delta F. Changes to power equipment in kitchen: 3 circuits. Sheets modified are E3.0,4.0,4.1. Plan check at counter. New power/lighting system upgrade. electrical service for sub-lease space. T24. Area = 3450 sq. ft. 8 story building High rise	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77025	11041-20000-12543	8218 W 3RD ST	90048	5	138B173   923	5511030023	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			06/16/2011 12:00:00 AM			PC Approved	06/20/2011 12:00:00 AM	ADDRESS	34.07236	-118.36861	T.I. to existing space.  Install general/emergency lighting.  Plan check for energy only. Existing permit 11041-20000-09348	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77026	18041-20000-03844	6909 ESTEPA DR	91042	7	198B201   113	2572031017	RE11-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2018 12:00:00 AM	02/01/2018 12:00:00 AM		Permit Finaled	02/07/2018 12:00:00 AM	PIN	34.24183044	-118.28239542	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWac and consists of (17) modules, (17) micro-inverters, and (1) load center. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77027	10041-20000-10022	916 S MAIN ST	90291	11	109-5A143 472	4286013031	C2-1	West Los Angeles	Venice	Venice		2734.02	Electrical	Electrical	Commercial			05/26/2010 12:00:00 AM			PC Info Complete	05/26/2010 12:00:00 AM	ADDRESS	33.99203	-118.47369	energy plan check office space	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77028	19041-10000-01637	7601 N CARMENITA LANE	91304	12	186B089    46	2017028041	RE11-1-H	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/15/2019 12:00:00 AM	01/22/2019 12:00:00 AM		Permit Finaled	02/04/2019 12:00:00 AM	ADDRESS	34.20984	-118.65592	PC FOR PV SYSTEM. SYSTEM CONSISTS OF 21KW (DC) AND 17.6KW(AC). (60) MODULES JINKO JKM365M-72-V. 60 OPTIMIZER SOLAREDGE P400. 2 INVERTER SOLAREDGE 10000H- SECOND IS 7.6 K. 125 LOAD CENTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77029	18041-10000-36992	1441 N GAFFEY ST	90731	15	024B197   461	7445002003	M1-2D-CPIO	Harbor	San Pedro	Northwest San Pedro		2963.00	Electrical	Electrical	Commercial			09/27/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	11/05/2018 12:00:00 AM	ADDRESS	33.75721	-118.29246	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77030	16041-10000-06446	963 E 4TH ST	90013	14	127-5A215 209	5163014013	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	07/20/2017 12:00:00 AM	ADDRESS	34.04337	-118.23442	PC FOR ENERGY AND POWER. CONVERT OFFICE/MANUFACTURING/WAREHOUSE  TO RESTAURANT/RETAIL/OFFICE AND ADD ONE STORY OFFICE, RESTAURANT, ROOF DECK TO EXISTING COMMERICAL BUILDING. CORE & SHELL. TOTAL AREA 13275 SQ FT.GENERATOR AND DISTRIBUTION BOARD  APPROVED ON SEPARATE APPLICATION	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77031	19041-10000-51248	11245 N ALTA AVE Lot 41	91345	7	210B145   565	2664028002	C1-1VL, P-1, P-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	01/10/2020 12:00:00 AM		Permit Finaled	09/08/2020 12:00:00 AM	ADDRESS	34.27496	-118.46884	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR AN EXISTING SERVICE OF 200 AMPS. INSTALLATION INCLUDES 13 MODULES (13 HANWHA Q.PEAK BLK-G5315), 13 OPTIMIZERS (P320), AND 1 CENTRAL INVERTER (SE3800H)SYSTEM SIZE: 4.095 KW DC;  3.8 KW AC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77032	19041-10000-28042	660 S CLUB VIEW DR	90024	5	138B157    89	4359013012	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			07/31/2019 12:00:00 AM	11/07/2019 12:00:00 AM		Permit Finaled	12/03/2021 12:00:00 AM	ADDRESS	34.07194	-118.42762	POWER PLAN CHECK FOR  A NEW 1200A 120/208 3� 4W ELECTRICAL SYSTEM FOR A SINGLE FAMILT DWELLING. SCOPE INCLUDES NEW 150KW BACKUP/EM DIESEL GENERATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77033	17041-20000-04965	8521 N FALLBROOK AVE SUITE 240	91304	12	192B097   583	2005022002	[Q]M1-1	North Valley	Chatsworth - Porter Ranch	West Hills	YES	1132.31	Electrical	Electrical	Commercial			02/15/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	05/05/2017 12:00:00 AM	ADDRESS	34.22368	-118.62797	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT. INTERIOR OFFICE T.I ( NOT MEDICAL).  7374 SQFT. SUITE 240	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77034	15041-10000-04943	523 W 6TH ST Ste 728	90013	14	129A209    44	5149030002	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			02/19/2015 12:00:00 AM	06/29/2015 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	PIN	34.04872199	-118.25441618	Interior office renovation in (E) commercial highrise building.  Plan check for energy - 1500 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77035	19041-20001-42373	1210 N CHANTILLY ROAD	90077	5	147B149   574	4369037012	RE20-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			10/17/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.09496	-118.45667	PV1.  Install 5.84 kW roof mounted grid tied PV system with 27 kWh energy storage system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77036	16041-20001-13032	17420 W DONMETZ ST	91344	12	210B129   176	2711012032	RA-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			04/14/2016 12:00:00 AM			PC Approved	05/16/2016 12:00:00 AM	ADDRESS	34.27433	-118.51382	Expedited fee RSES. PV1.  Install 8.96 kW roof-mounted PV system.  (2) 5.0 kW central inverters with (32) 280W modules.  320A rated service equipment.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77037	14041-20000-13084	12701 W VAN NUYS BLVD SUITE D	91331	7	213B161   907	2533019024	[Q]MR2-1-CDO	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	Commercial			05/15/2014 12:00:00 AM	05/15/2014 12:00:00 AM		Permit Finaled	06/16/2014 12:00:00 AM	ADDRESS	34.27621	-118.41056	Commercial office and storage TI.  Title 24 plan check for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77038	18041-10001-18230	8525 N VARIEL AVE	91304	3	192B105   176	2779011036	RA-1	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.34	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2018 12:00:00 AM			PC Approved	06/13/2018 12:00:00 AM	ADDRESS	34.22506	-118.59302	Expedited FeesPV1, roof mounted solar system using central inverters. (88) modules and (3) 7KW inverters. Total system size is 21KWAC and 23.6 KWDC.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77039	10041-10000-23368	7326 W MELROSE AVE	90036	5	141B181   615	5526021026	C4-1XL	Central	Hollywood	Mid City West		1920.00	Electrical	Electrical	Commercial			11/22/2010 12:00:00 AM	11/23/2010 12:00:00 AM		Permit Finaled	05/03/2011 12:00:00 AM	PIN	34.08329257	-118.34963932	ALTERATIONS IN A BEAUTY SALONPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77040	17041-10000-00451	11109 N SEPULVEDA BLVD Suite 101	91345	7	210B145   124	2664007011	C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1091.00	Electrical	Electrical	Commercial			01/09/2017 12:00:00 AM	03/03/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.27256	-118.46785	PC FOR POWER AND ENERGY FOR A COFFE SHOP TI WITH NEW EQUIPMENT, LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA OF 1900 SQ.FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77041	19041-20000-01570	1641 N POINSETTIA PL 1-20	90046	4	147B181   167	5548009002	R3-1	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Apartment			01/14/2019 12:00:00 AM	01/14/2019 12:00:00 AM		Permit Finaled	03/01/2019 12:00:00 AM	ADDRESS	34.10115	-118.34797	plan check for new em lighting and exit signs to an existing apartment building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77042	10041-10000-19073	1438 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   369	5021002001	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2316.00	Electrical	Electrical	Commercial			09/24/2010 12:00:00 AM	11/03/2010 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	ADDRESS	34.01068	-118.3017	TI IN AN EXISTING RETAIL. PLAN CHECK FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77043	13041-10000-33027	12627 W MILBANK ST	91604	2	168B161  1034	2362017015	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2013 12:00:00 AM	01/03/2014 12:00:00 AM		Permit Finaled	01/22/2014 12:00:00 AM	ADDRESS	34.15327	-118.40838	PV1, Install 7.5 kW DC roof-mounted solar array, interconnect with service panel.(2) Transformerless inverter(s):Solaredge SE3000A-US, power optimizer,  SolarEdge SE3800A-US. (30) modules TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77044	11041-10000-12385	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			06/15/2011 12:00:00 AM	07/27/2011 12:00:00 AM		Permit Finaled	02/24/2012 12:00:00 AM	ADDRESS	34.05855	-118.23671	T.I.  Remodel in an existing building in the basement for a data center.  The building is 4 stories high.  Plan check is for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77045	15041-20000-02742	12484 W OSPREY LANE UNIT 1	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Permit Finaled	08/28/2015 12:00:00 AM	ADDRESS	33.9788	-118.4106	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #1 OF THREE UNITS.THE ZONING CLEARANCE FOR THIS APPLICATION SHALL APPLY TO ALL THREE UNITS WITHIN THIS SCOPE OF WORK.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77046	14041-20000-26290	505 N HAYWORTH AVE	90048	5	141B177  1154	5527019011	R3-1XL	Central	Hollywood	Mid City West		1944.01	Electrical	Electrical	Apartment			09/23/2014 12:00:00 AM	11/21/2014 12:00:00 AM		Permit Finaled	02/19/2016 12:00:00 AM	ADDRESS	34.08027	-118.36291	NEW 2-STORY 5 UNIT APARTMENT WITH SUBTERRANEAN BASEMENT PARKING GARAGE [FIRE SPRINKLERS REQ'D THROUGH-OUT].  800A SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77047	11041-10000-11205	1045 S BLAINE ST	90015	1	129A205   350	5137012023	[Q]C2-1-O	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			06/01/2011 12:00:00 AM	06/01/2011 12:00:00 AM		Permit Finaled	11/23/2011 12:00:00 AM	ADDRESS	34.04619	-118.27099	"NEW TWO ILLUMINATED WALL SIGNS, AREA=5.9 SQ FT  EACH , SIGN TO READ ""76"".  EPC is for T24. (Building permit was issued under 11041-10000-00860)"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77048	17041-20001-15635	700 S NEW HAMPSHIRE AVE	90005	10	132B197   232	5094011018	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2123.03	Electrical	Electrical	Commercial			05/10/2017 12:00:00 AM			PC Approved	06/14/2017 12:00:00 AM	ADDRESS	34.05951	-118.29274	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof mounted on commercial building.9.6kW ungrounded system. (40) EnPhase M250 microinverters.(40) 340W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77049	19041-20000-15417	15755 W SATICOY ST	91406	6	186B141    61	2206011021	R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Apartment			04/26/2019 12:00:00 AM	07/26/2019 12:00:00 AM		Permit Finaled	07/20/2021 12:00:00 AM	ADDRESS	34.20857	-118.47675	Plan check for power and energy. Project site is a 3-story, 24-unit apartment building. Work includes a 1,200 amp service and a total lighting area of 31,226 sq. ft.Note: Building permit has been issued under 17010-20000-03176	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77050	13041-20000-04395	7128 N VAN NUYS BLVD	91405	6	183B149   109	2217007040	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			02/20/2013 12:00:00 AM	02/20/2013 12:00:00 AM		Permit Closed	06/05/2013 12:00:00 AM	ADDRESS	34.20002	-118.44856	NEW 7' X 10' PHARMACY KIOSK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77051	12041-20000-09018	8401 N VAN NUYS BLVD	91402	7	192B149   183	2638038016	[Q]C2-2D-CDO, [Q]P-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1201.01	Electrical	Electrical	Commercial			04/19/2012 12:00:00 AM	09/11/2012 12:00:00 AM		Permit Finaled	11/16/2012 12:00:00 AM	ADDRESS	34.22308	-118.44896	T.I. to existing building at the mercado area.  Install general/emergency lighting.  Plan check for energy only.  ((PERMIT FEES ARE UNDER INSPECTION))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77052	18041-10000-39377	802 E E ST	90744	15	030B209  1216	7424015063	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			10/15/2018 12:00:00 AM	10/15/2018 12:00:00 AM		Permit Finaled	03/20/2019 12:00:00 AM	ADDRESS	33.77585	-118.25274	PLAN CHECK FOR A ADDITION TO AN EXISTING SPACE. SCOPE OF WORK INCLUDES NEW LIGHTING AND RECEPTACLES ON THE 2ND AND 3RD FLOOR. TOTAL SQ. FT. 5535.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77053	17041-20000-08096	1714 S WALL ST	90015	14	123A209   340	5127020037	M2-2-O	South Los Angeles	Southeast Los Angeles	Downtown Los Angeles		2260.01	Electrical	Electrical	Commercial			03/15/2017 12:00:00 AM	06/27/2018 12:00:00 AM		Issued	06/27/2018 12:00:00 AM	ADDRESS	34.02984	-118.25936	PLANCHECK FOR POWER ONLY. SERVICE UPGRADE TO 800 AMPS FOR EXISITNG MANUFACTURING BUILDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77054	19041-10000-00825	5801 W PICO BLVD	90019	10	129B177   431	5086015030	C4-1-O	Central	Wilshire	P.I.C.O.		2169.00	Electrical	Electrical	Commercial			01/08/2019 12:00:00 AM	10/05/2020 12:00:00 AM		Permit Finaled	03/21/2023 12:00:00 AM	ADDRESS	34.05129	-118.36466	FULL PLAN CHECK (N) 5 Story 80 unit apartment over 1 story of commercial and 2 levels of subterranian parking - SERVICE SIZE = 2500A 120/208V 3 PHASE SYSTEM WITH 13 TYPICAL UNITS WITH A TOTAL AFFECTED AREA = 31032 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77055	13041-10003-21489	5837-5841 W SUNSET BLVD UNITS 1-79	90028	13	147A191    55	5545011023	(T)(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			06/15/2016 12:00:00 AM			PC Approved	06/15/2016 12:00:00 AM	ADDRESS	34.09822	-118.3171	PC FOR CHANGES TO APPROVED SET OF PLANS. NEW ENGINEER FOR DELTA CHANGES ONLY. ALL CHANGES CLOUDED DELTA 10. NEW WIRING METHODS FOR UNIT PANELS. PC FOR CHANGES INCLUDE NEW FAULT CURRENT CALCS AND VOLTAGE DROPS.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77056	15041-10000-10755	10269 W SANTA MONICA BLVD 1-19	90024	5	132B157   294	4327018011	(T)(Q)RAS4-1VL-O	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Apartment			04/10/2015 12:00:00 AM	04/10/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.05994	-118.42117	New fire alarm system for a new 4-sotry 19-unit apartments; scope includes (1) fire alarm panel, (2) controll panels,  and (99) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77057	17041-10000-19442	215 W PACIFIC COAST HWY	90744	15	036B205  1085	7421023008	[Q]C2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2942.00	Electrical	Electrical	Commercial			06/09/2017 12:00:00 AM	06/09/2017 12:00:00 AM		Permit Closed	01/12/2023 12:00:00 AM	ADDRESS	33.79119	-118.26531	REPLACE HID FIXTURES FOR LED TYPE(18 FIXTURES). TOTAL AFFECTED AREA 20800 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77058	14041-10001-12882	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/15/2014 12:00:00 AM			PC Approved	12/15/2014 12:00:00 AM	ADDRESS	34.0484	-118.26248	CHANGES TO APPROVED SET,  ADDING 4 DEVICES TO EXISTING FIRE ALARM SYSTEM. PERMIT IS EXISTING, THIS IS A PLAN CHECK ONLY(((NEW FA FOR parking structure. not a highrise per building application.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77059	10041-20000-06655	19749 W DEARBORN ST	91311	12	198B117   164	2761001055	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.01	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	04/12/2010 12:00:00 AM		Permit Finaled	06/01/2010 12:00:00 AM	ADDRESS	34.23748	-118.56389	Plan check T-24 Energy for new interior bathroom in existing commercial office/studio building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77060	11041-20000-01733	4849 N VAN NUYS BLVD #102	91403	2	169-5A151  98	2263024050	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02, 1289.10	Electrical	Electrical	Commercial			01/28/2011 12:00:00 AM	06/02/2011 12:00:00 AM		Permit Finaled	07/26/2011 12:00:00 AM	ADDRESS	34.15918	-118.44892	Plan check power and energy for TI to dental office suite #102	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77061	11041-10000-01643	900 N ALAMEDA ST	90012	14	133-5A215 345	5409015015	ADP	Central	Central City North	Historic Cultural		2060.20	Electrical	Electrical	Commercial			01/27/2011 12:00:00 AM	03/03/2011 12:00:00 AM		Permit Finaled	06/07/2011 12:00:00 AM	ADDRESS	34.05855	-118.23671	Add UPS system for a data center. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77062	15041-20001-03074	12491 W OSPREY LANE UNIT 2	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM			PC Approved	03/01/2015 12:00:00 AM	ADDRESS	33.97895	-118.41081	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #2 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77063	18041-10000-42832	2420 W RIPPLE ST	90039	13	150A209    19	5437033034	M2-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Issued	11/08/2018 12:00:00 AM	PIN	34.10725085	-118.25404613	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77064	14041-10000-25156	14500 W ROSCOE BLVD	91402	6	192B149   401	2210010039	[Q]C2-2D-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			09/12/2014 12:00:00 AM	11/17/2014 12:00:00 AM		Permit Finaled	01/26/2015 12:00:00 AM	ADDRESS	34.22136	-118.44937	Power and energy plan check for commercial office TI on the 5th  floor st 500 . total area is 10113.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77065	14041-20000-09881	20138 W ELKWOOD ST	91306	3	189B113  1043	2107022050	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.04	Electrical	Electrical	1 or 2 Family Dwelling			04/15/2014 12:00:00 AM	05/01/2014 12:00:00 AM		Permit Finaled	07/11/2014 12:00:00 AM	ADDRESS	34.21222	-118.57234	PV1.  Install 12.25 kW roof-mounted PV system, interconnect with existing main service panel.  Transformerless inverter: SolarEdge SE6000A w/ power optimizers.  (49) modules.(($0 permit fee due to senate bill 1222 from 2012))	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77066	16041-10000-31733	269 S SAN PEDRO ST	90012	14	129A213   450	5161025***	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			09/07/2016 12:00:00 AM	02/09/2017 12:00:00 AM		Permit Finaled	08/18/2017 12:00:00 AM	ADDRESS	34.0477	-118.2427	"Full Plan check, Change of use from office to ""Urgent Care"". (3) panels are existing with new circuits. Total affected area: 3,562 sq.ft. ((B#  16016-10000-20249))"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77067	14041-20000-21433	9270 W WARBLER WAY	90069	4	147B169   532	5561021012	RE11-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2014 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/08/2014 12:00:00 AM	ADDRESS	34.09893	-118.39172	PV1.  Install 5.13 kW roof-mounted, utility-interactive PV system.  Enphase M215 microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77068	15041-10001-13541	7201 S WESTERN AVE	90047	8	102B193  1444	6017001039	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	Commercial			03/07/2016 12:00:00 AM			PC Approved	03/07/2016 12:00:00 AM	ADDRESS	33.97433	-118.30917	Supplemental PC only . T-24 for outdoor lighting at Jack in the Box 5312. Total area: 20,521 sq. ft. Permit under 15041-10000-13541.***REPLACING EXISTING EXTERIOR AND PARKING LOT LIGHTS W/ LED'S	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77069	16041-10000-00665	633 W 5TH ST 43rd floor	90071	14	130-5A209 152	5151017028	C5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			01/08/2016 12:00:00 AM	05/02/2016 12:00:00 AM		Permit Finaled	09/23/2016 12:00:00 AM	ADDRESS	34.05099	-118.25468	TI to (E) office build 43rd floor. Install new lighting and control receptacle. PC for energy only. Total area: 1,954 sq.ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77070	14041-10001-25628	7250 N HAZELTINE AVE	91405	2	186B153   714	2216002058	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1271.04	Electrical	Electrical	Apartment			09/17/2014 12:00:00 AM			PC Approved	10/16/2014 12:00:00 AM	ADDRESS	34.20287	-118.43981	(((Supp application for expedite fee)))installation of rooftop solar photovoltaic system for multi-family affordable housing.  System size = 22.8 IWac	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77071	14041-20001-12217	23133 W OSTRONIC DR	91367	3	171B093   404	2042014014	R1-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM			PC Approved	05/28/2014 12:00:00 AM	ADDRESS	34.16483	-118.63107	EXPEDITE PER APPLICANT REQUEST[[[PV1Install roof mounted solar array on SFD and on attached garage. System size: 11.2kW(1) SolarEdge SE-10000A-US-240V transformerless inverter(40) SunModule Plus SW-270 mono pv modules(40) power optimizers 300W each]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77072	11041-10000-09157	11818 W DOROTHY ST 1-26	90049	11	129B145   285	4265017049	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2643.01	Electrical	Electrical	Apartment			05/05/2011 12:00:00 AM	12/20/2011 12:00:00 AM		Permit Finaled	10/15/2012 12:00:00 AM	ADDRESS	34.05151	-118.4671	NEW 4 STORY 26 UNIT APARTMENT BUILDING.  <<<<FIRE ALARM REQ. VARIANCE WILL BE SUBMITTED TO SEPERATE THE PLANS>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77073	13041-20000-06172	20700 W NORTHRIDGE ROAD	91311	12	210B113    53	2707002001	A1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/08/2013 12:00:00 AM	05/28/2013 12:00:00 AM		Permit Finaled	03/17/2015 12:00:00 AM	ADDRESS	34.27146	-118.57213	Total rework of electrical for an existing single family residence.  New 1200 amp service, circuits, loads.  Full plan check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77074	17041-10000-22097	515 S FLOWER ST STE 3700	90071	14	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	04/05/2018 12:00:00 AM	ADDRESS	34.05134	-118.25661	PC FOR OFFICE TI IN A HIGH RISE BUILDING. TOTAL CONNECTED LOAD <400A.  INSTALLING NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA 23,375 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77075	13041-10001-34462	6726 N KENTLAND AVE	91307	12	180B101   107	2038031001	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	West Hills		1351.02	Electrical	Electrical	1 or 2 Family Dwelling			12/12/2013 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.1926	-118.61746	Expedited RSES plan check per applicant request.{{PV1, Install a 4.75 kw DC roof-mounted solar array system interconnect with main service panel with (1) transformerless inverter(s)[SOLAREDGE # SE3800A-US] and (19) modules[TRINA SOLAR # TSM-250PA05.18] for 2-story house. With power optimizer.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77076	19041-10000-08459	953 N SYCAMORE AVE 7TH FLR	90038	4	144B181   641	5531015010	MR1-1	Central	Hollywood	Central Hollywood		1919.01	Electrical	Electrical	Commercial			03/08/2019 12:00:00 AM	03/22/2019 12:00:00 AM		Permit Finaled	09/10/2019 12:00:00 AM	ADDRESS	34.08865	-118.34299	Energy plan check for an office T.I located on the 7th floor of a commercial building. Scope includes new light and equipment with a total area of 11,597 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77077	18041-10003-19931	6761 S ARLINGTON AVE	90043	8	102B189   869	4008017030	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2352.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2018 12:00:00 AM			PC Approved	07/24/2018 12:00:00 AM	ADDRESS	33.97655	-118.31885	EXPEDITE PER APPLICANT REQUEST ON THE PV PORTION OF THE WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77078	16041-20000-28401	22769 W DEL VALLE ST	91364	3	171B097   499	2040031050	R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1372.01	Electrical	Electrical	Apartment			08/10/2016 12:00:00 AM	04/03/2017 12:00:00 AM		Permit Closed	10/31/2018 12:00:00 AM	ADDRESS	34.16551	-118.62275	Plan check for power and energy. New 22-unit apartment building. 4 stories over basement parking garage.  1,200A service. Fire alarm variance NOT filed at time of submittal.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77079	13041-20000-34680	5053 N FAIR AVE	91601	2	171B173  1010	2353012012	R4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Apartment			12/12/2013 12:00:00 AM	03/10/2015 12:00:00 AM		Permit Finaled	10/28/2016 12:00:00 AM	ADDRESS	34.16224	-118.37474	New 36 unit apartment building.   New 1200 amp service.  Full Plan Check.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77080	19041-20000-15541	6121 W SUNSET BLVD 4th-5th Floors	90028	13	147A189   234	5546026044	(T)(Q)C4-2-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			04/26/2019 12:00:00 AM	05/01/2019 12:00:00 AM		Issued	05/01/2019 12:00:00 AM	ADDRESS	34.09818	-118.32309	Plan check for Title 24 only. Project site is a portion of the 4th and 5th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 7,842 sq. ft.Note: Building permits have been issued under 19016-30000-05627/05619	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77081	17041-10000-34254	20101 S HAMILTON AVE UNIT 150B	90502	15	057B197    85	7351033017	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			09/25/2017 12:00:00 AM	09/28/2017 12:00:00 AM		Issued	09/28/2017 12:00:00 AM	ADDRESS	33.84769	-118.28637	PC for T24 only for credit union TI. Total area of 7486 sqft. Building# 17016-30000-26437	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77082	17041-10001-04619	20045 W RINALDI ST BLDG A5	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	04/11/2018 12:00:00 AM		Permit Finaled	03/18/2021 12:00:00 AM	ADDRESS	34.27564	-118.57092	Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding site lighting, replacing exterior lights, revising panel schedules, and revising title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77083	18041-20001-15682	6050 W CADILLAC AVE	90034	10	126B173  1006	5066001048	R3-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	P.I.C.O.		2703.00	Electrical	Electrical	Apartment			06/12/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.03776	-118.37635	Revisions to approved plans and system redesign/reduction.  Change to (14) modules with microinverters.  System size change to 4.2 kW. (((Plan check for PV roof mounted system. System size: 8.9kWac with 27 modules and 27 microinverters install on apartment building. PV system is connected to service supply side.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77084	15041-20002-17388	385 E SWINFORD ST	90731	15	021B201   194	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			04/20/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	04/26/2016 12:00:00 AM	ADDRESS	33.7494	-118.27878	04/20/2016 Changes to an approved set of plans. Changes have been made to reflect field changes. All changs have been clouded and marked as Delta 5.*****Previous Work Description*****PC FOR FULL BUILDING. TI BUILD OUT. PC FOR POWER AND ENERGY. 600A SERVICE APPROVED AND PERMITTED UNDER MASTER APPLICATION	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77085	19041-20001-06218	16055 W VENTURA BLVD Suite 120	91436	5	168B141   524	2261022023	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			05/15/2019 12:00:00 AM			PC Approved	05/15/2019 12:00:00 AM	ADDRESS	34.15653	-118.4831	05/15/2019 Changes to an approved set of plans. All changes have been clouded and marked as Delta B. Single line diagram configuration has changed.*****Original Work Description*****Plan check for power only. Project site is an existing outpatient surgical center in commercial high-rise building. Project scope is the addition of emergency panels and the separation of existing circuits into their respective panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77086	19041-10000-50963	7213 S ARIZONA AVE	90045	11	102B165   492	4110004050	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			12/17/2019 12:00:00 AM	01/14/2020 12:00:00 AM		Permit Finaled	04/15/2020 12:00:00 AM	ADDRESS	33.97471	-118.39614	(E-PLAN)NEW PV1 ROOF-MOUNTED INSTALLATION FOR A SERVICE OF 225 AMPS. INSTALLATION INCLUDES 49 MODULES (SOLARIA PTX355R-AC 355W), 49 MICROINVERTERS (ENPHASE IQ7PLUS-72-2-US ), AND 1 COMBINER BOXSYSTEM SIZE: 17.395 KW DC; 14.21 KW AC*NOTE: PANEL UPGRADE UNDER A SEPARATE PERMIT	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77087	16041-10000-23313	10250 W SANTA MONICA BLVD 202	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			07/01/2016 12:00:00 AM	09/08/2016 12:00:00 AM		Permit Finaled	01/19/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	PC FOR POWER AND ENERGY. THE INTERIOR BUILDING OUT OF AN EXISTING SHELLED OUT TENANT SPACE INCLUDING EXTERIOR PATIO ON THE SAME FLOOR OF A SINGLE STORY BUILDING. TOTAL AREA (2160+ 465) SQ FT.B# 16016-10000-15382	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77088	18041-20001-34143	11444 W ALBATA ST	90049	11	135B145   719	4365017008	R1-1-O	West Los Angeles	Brentwood - Pacific Palisades			2654.10	Electrical	Electrical	1 or 2 Family Dwelling			09/06/2018 12:00:00 AM			PC Approved	09/11/2018 12:00:00 AM	ADDRESS	34.06314	-118.4621	Expedited plan check fee.PV1.  Install 11.025 kW DC roof mounted grid tied PV system.  (35) modules with 11.4 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77089	18041-10000-42859	5977 N HILLVIEW PARK AVE	91401	2	177B157   872	2343020001	RE11-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1236.02	Electrical	Electrical	1 or 2 Family Dwelling			11/08/2018 12:00:00 AM	11/08/2018 12:00:00 AM		Permit Finaled	04/23/2019 12:00:00 AM	ADDRESS	34.17896	-118.42849	PLAN CHECK FOR ROOFTOP MOUNTED 8.125 kw DC PV SYSTEM WITH (25) MODULES , (1) AC INVERTER WITH 7.6 KW,  (1) POWER OPTIMIZER P400.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77090	15041-20000-18024	13400 N GLENOAKS BLVD	91342	7	225B145   115	2502028020	RE11-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			06/10/2015 12:00:00 AM	06/30/2015 12:00:00 AM		Permit Finaled	08/01/2015 12:00:00 AM	ADDRESS	34.31591	-118.46014	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP. Derating main to 175A.System size: 11.4kW. Ungrounded system. Using 300W power optimizers. (53) 260W pv modules.Note: $0.00 permit fees due to Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77091	19041-20000-34348	126 N GLENDALE BLVD	90026	1	135A209   387	5160013005	CW	Central	Westlake	Echo Park		2080.00	Electrical	Electrical	Commercial			08/30/2019 12:00:00 AM	02/12/2020 12:00:00 AM		Issued	02/12/2020 12:00:00 AM	ADDRESS	34.06266	-118.25957	Power and lighting for TI of (E) catering kitchen.  New load in excess of 400A.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77092	16041-10000-04110	1839 W 75TH ST	90047	8	102B193  1833	6017009019	R1-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2379.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2016 12:00:00 AM	02/05/2016 12:00:00 AM		Permit Finaled	03/17/2016 12:00:00 AM	ADDRESS	33.97197	-118.31026	PV1, rooftop solar 4.5kW system(21) HiS-S260RG(21) M215-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77093	19041-20000-46709	24114 W DE QUINCY CT	91304	12	189B089   120	2020031029	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			11/13/2019 12:00:00 AM	11/13/2019 12:00:00 AM		Permit Finaled	12/09/2019 12:00:00 AM	ADDRESS	34.21482	-118.65146	PV1 PLAN CHECK FOR PV SYSTEM, SYSTEM SIZE IS 12.54 KW DC/11.726 KW AC CEC. SCOPE OF WORK CONSISTS OF (38) PV MODULES WITH OPTIMIZERS AND A 10 KW INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77094	19041-30000-03783	11835 W OLYMPIC BLVD #1040E	90064	11	123B149   469	4259023018	M2-2	West Los Angeles	West Los Angeles	West Los Angeles Sawtelle		2676.00	Electrical	Electrical	Commercial			01/31/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Permit Finaled	03/14/2019 12:00:00 AM	ADDRESS	34.03301	-118.45119	Plan check for Title 24 only. Project site is an existing tenant suite in a commercial building. Project scope is a tenant improvement. Total lighting area = 1,053 sq. ft.Note: Building permit has been issued under 19016-40000-02698	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77095	15041-20000-27348	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			08/20/2015 12:00:00 AM			PC Approved	08/20/2015 12:00:00 AM	ADDRESS	34.06338	-118.20434	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR MULTIPURPOSE ROOM AT USC CHP G20.  1720 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77096	15041-30002-18117	2320 W SLAUSON AVE	90043	8	108B189  1390	4005025002	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Park Mesa Heights		2347.00	Electrical	Electrical	Commercial			12/31/2015 12:00:00 AM			PC Approved	12/31/2015 12:00:00 AM	ADDRESS	33.98894	-118.31933	Title 24 plan check only.  Total area = 1,858 sq. ft.Plan check only.  Permit issued under master application (10000)***Previous work description***     UPGRADE PANEL (400) AMP, (2) SUB PANELS (200) AMP.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77097	15041-10000-34001	11432 W VANOWEN ST	91606	2	180B169    32	2320018022	C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1232.05	Electrical	Electrical	Commercial			10/13/2015 12:00:00 AM	10/13/2015 12:00:00 AM		Permit Finaled	03/07/2016 12:00:00 AM	PIN	34.19366274	-118.38033118	NEW FIRE ALARM SYSTEM 42 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77098	15041-10000-04002	1143 S BOYLE AVE	90023	14	123A219   117	5170008***	MR2-1-RIO	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			02/10/2015 12:00:00 AM	02/10/2015 12:00:00 AM		Permit Finaled	03/02/2015 12:00:00 AM	ADDRESS	34.03005	-118.22064	T24 only. remove hid light fixtures and replace with LED fixtures. total area 4678 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77099	13041-10000-28851	4260 S LINCOLN BLVD	90292	11	105B153    73	4230001018	[Q]M2-1-CDO	West Los Angeles	Venice	Venice		2741.00	Electrical	Electrical	Commercial			10/16/2013 12:00:00 AM	10/17/2013 12:00:00 AM		Permit Finaled	11/27/2013 12:00:00 AM	ADDRESS	33.98611	-118.44341	permit to be pulled at EPC counter only. PC for energy. TI TO (E) BLDG: PINKBERRY TO SNOW FLOWER (RESTAURANT). less than 400A. 25maxoccupants per bldg. height:54ft (not a high rise)description from 13016-10000-19477:NONSTRUCT INT REMODEL & CHANGE OF USE FROM RETAIL TO TAKE-OUT RESTAURANT (NO SEATING) - 604SF (NO ONSITE CONSUMPTION OF ALCOHOLIC BEVERAGES)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77100	19041-10000-22739	4787 W SANTA MONICA BLVD	90029	13	144B197   714	5540022018	C2-1D	Central	Hollywood	East Hollywood		1912.03	Electrical	Electrical	Commercial			06/14/2019 12:00:00 AM	06/14/2019 12:00:00 AM		Issued	06/14/2019 12:00:00 AM	ADDRESS	34.09103	-118.29371	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77101	19041-10000-51639	546 N HARVARD BLVD 1-9	90004	13	141B193   969	5521010004	R3-1	Central	Wilshire	Wilshire Center-Koreatown		1925.20	Electrical	Electrical	Apartment			12/13/2019 12:00:00 AM	12/01/2020 12:00:00 AM		Permit Finaled	10/23/2023 12:00:00 AM	ADDRESS	34.08126	-118.30448	Plan check for a new apartment building , service size 800A, 120/240v,4w, 3ph. Area of scope (1052)SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77102	15041-20000-29449	7945 N ORION AVE	91406	6	189B145   318	2222037005	M2-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1273.00	Electrical	Electrical	Commercial			09/08/2015 12:00:00 AM	09/15/2015 12:00:00 AM		Permit Finaled	11/23/2015 12:00:00 AM	ADDRESS	34.21496	-118.4707	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 3,078 sq. ft.Note: Building permit filed under applcation number 15016-20000-14843	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77103	12041-10000-12770	2266 W 25TH ST	90018	10	123B189   564	5058004005	[Q]R4-1-O-HPOZ	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2214.00	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2012 12:00:00 AM	06/20/2012 12:00:00 AM		Permit Finaled	08/31/2012 12:00:00 AM	ADDRESS	34.03367	-118.31679	New 4.18kw rooftop photovoltaic system for an existing single family residence.  All conduit runs are exterior.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77104	19041-20000-51043	147 S CITRUS AVE	90036	5	138B181  1065	5513015024	R1V3-RG	Central	Wilshire	Greater Wilshire		2141.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2019 12:00:00 AM	12/11/2019 12:00:00 AM		Permit Expired	11/12/2023 12:00:00 AM	ADDRESS	34.07223	-118.33986	PV1. INSTALL 11.375 KW DC PV SYSTEM WITH (35) MODULES/OPTIMIZERS AND (1) INVERTER (SE11400)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77105	15041-20000-26339	7012 N ALDEA AVE	91406	6	183B133   505	2227024025	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1320.02	Electrical	Electrical	1 or 2 Family Dwelling			08/13/2015 12:00:00 AM	08/17/2015 12:00:00 AM		Permit Finaled	09/01/2015 12:00:00 AM	ADDRESS	34.19794	-118.50864	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter, (24) modules, (24) power optimizers, and (1) combiner box. Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77106	18041-20000-21412	3715 S MCCLINTOCK AVE Lobby-2nd Floor	90089	9	117B197     6	5039002034	USC-1A	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			06/08/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	11/16/2018 12:00:00 AM	ADDRESS	34.02041	-118.29027	Plan check for Title 24 Energy only in existing lobby and 2nd floor office. Total area: 2635 sq ft.B#18016-1000014359	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77107	13041-10002-31593			14	129A211   253	5148020004	C2-2D	Central	Central City	Downtown Los Angeles		2073.02	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM			PC Approved	12/11/2015 12:00:00 AM	PIN	34.04564656	-118.24903553	((12-11-15: CHANGES MADE TO APPROVED SET. CHANGED FACADE LIGHTING. NET NUMBER OF CIRCUITS HAVE NOT CHANGED, THIS IS A PLAN CHECK ONLY APPLICATION)) POWER AND ENERGY PLAN CHECK FOR  A NEW MIXED USE BUILDING. NEW 7 STORY APARTMENT/RETAIL ( 2 LEVELS OF RETAIL ON THE BOTTOM AND 5 LEVELS OF APARTMENT). NOT A HIGHRISE ACCORDING TO APPLICANT.TOTAL OF 159 UNITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77108	17041-20001-16632	1465 N TAMARIND AVE	90028	13	147A191    91	5545014004	[Q]C4-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			10/25/2019 12:00:00 AM			PC Approved	10/25/2019 12:00:00 AM	ADDRESS	34.09754	-118.31918	10-25-2019 Changes to an approved set of plan, changes include new lighting fixture being replace from proviouse plan approval, new emergency light layout, all changes has been clouded. Plan check only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77109	19041-10000-38873	13070 W KELOWNA ST	91331	7	204B161   778	2623021016	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1048.10	Electrical	Electrical	1 or 2 Family Dwelling			09/26/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	10/08/2019 12:00:00 AM	ADDRESS	34.25231	-118.41727	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE  IS 3.66KWdc / 3.80KWac.(12)MODULES- HANWHA Q CELL 305 WATTS(12)OPTIMIZERS- SOLAREGDGE P320(1)INVERTER-SOLAREDGE SE 3800H-US RGM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77110	11041-10004-12353	620 W 2ND ST	90012	9	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.00	Electrical	Electrical	Commercial			07/22/2013 12:00:00 AM			PC Approved	09/24/2013 12:00:00 AM	ADDRESS	34.0545	-118.25027	(((((((((((CHANGES MADE TO ORIGINAL SET OF PLANS FOR A PARKING GARAGE , 7-22-13, MISCELLANEOUS CHANGES, MAJOR CHANGES ARE MADE ON SINGLE-LINE DIAGRAM , REVISED EMERGENCY FEED TO FIRE PUMP. APPLICATION IS MADE FOR CHANGES ON APPLICATION # 11041-10001-12353 ))))))))))))))))REVISED APPROVED SETOF PLANS- NEW LOADS WERE ADDED TO THE SERVICE FOR THE PARKING STRUCTURE. THIS INCLUDES A FIRE PUMP, PANELBOARDS AND UPGRADING DISTRIBUTION BOARDS WHEN NECESSARY. CHANGES TO THE LIGHTING SYSTEM IS MINIMAL.((((((((((NEW PARKING STRUCTURE / MUSEUM BUILDING ( 3-LEVELS PARKING AND 3-LEVELS FOR MUSEUM) THIS APPLICATION  IS FOR THE SERVICE AND DISTRIBUTION FOR THE PARKING STRUCTURE; APPLICATION FOR THE MUSEIUM WILL FOLLOW	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77111	18041-10000-35875	13161 W SHERMAN WAY	91605	2	183B157    34	2327003029	CM-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood West		1220.00	Electrical	Electrical	Commercial			09/19/2018 12:00:00 AM	09/20/2018 12:00:00 AM		Permit Finaled	12/07/2018 12:00:00 AM	ADDRESS	34.20137	-118.41992	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77112	16041-20000-33369	6233 W FOUNTAIN AVE 1-89	90028	13	144B189    56	5546020024	R3-1XL	Central	Hollywood	Central Hollywood		1908.01	Electrical	Electrical	Apartment			09/20/2016 12:00:00 AM	09/20/2016 12:00:00 AM		Permit Finaled	04/20/2018 12:00:00 AM	ADDRESS	34.09447	-118.32537	Plan check for the replace of (1) FACP and (1) annunciator, and the addition of (1) communication panel, (51) control modules, and (5) smoke detectors to an existing fire alarm system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77113	17041-20000-09901	12601 W PIERCE ST Bldg 16	91331	7	210B161   257	2536010015	RD1.5-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1041.05	Electrical	Electrical	Apartment			03/28/2017 12:00:00 AM	01/30/2018 12:00:00 AM		Permit Finaled	04/22/2019 12:00:00 AM	ADDRESS	34.27174	-118.40738	Plan check for installation of solar pv array, roof-mounted on apartment building (buildings 16).5kW AC/5.6kw DC ungrounded system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77114	09041-10001-19969	8800 S SEPULVEDA BLVD	90045	11	096B165   956	4123001001	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			02/02/2010 12:00:00 AM			PC Approved	02/02/2010 12:00:00 AM	ADDRESS	33.95697	-118.39597	Revision to approved plans, plan check only.  Revisions are clouded on plans. TI for a bank.  T-24 and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77115	11041-20000-23939	221 S GRAND AVE	90012	14	132A211    61	5151004913	[T][Q]C2-4D	Central	Central City	Downtown Los Angeles		2075.02	Electrical	Electrical	Commercial			11/08/2011 12:00:00 AM	12/05/2011 12:00:00 AM		Permit Expired	12/30/2013 12:00:00 AM	ADDRESS	34.05419	-118.2505	TEMP.POWER 1200 AMPS. BROAD MUSEUM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77116	14041-20001-13576	5076 N ENCINO AVE	91316	5	171B129   284	2257016050	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2014 12:00:00 AM			PC Approved	06/25/2014 12:00:00 AM	ADDRESS	34.16371	-118.51404	Modification to approved set.  Changes made to service equipment to match field existing installation (center-fed panel).  Inclusion of service load calcs to justify derating of main breaker.  $0 plan check fee is due to Senate Bill SB-1222.  (((Roof mounted PV system with Enphase Microinverter, model M250-60-2LL.  PV system size 4.77KWdc.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77117	14041-20000-17064	800 W OLYMPIC BLVD STE 406	90015	9	127-5A207 340	5138007***	LASED	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/25/2014 12:00:00 AM	06/25/2014 12:00:00 AM		Permit Expired	08/03/2016 12:00:00 AM	ADDRESS	34.04484	-118.26453	TI to (E) commercial space in commercial highrise building.  Plan check for changes to lighting system - Title 24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77118	13041-10000-30121	18005 W DALI DR	91344	12	219B125    27	2601064010	RA-1-O-K	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM	11/22/2013 12:00:00 AM		Permit Expired	12/18/2015 12:00:00 AM	ADDRESS	34.29809	-118.52741	PV1, Install 7.25 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter: Solaredge SE 6000A-US. 29 modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77119	13041-10000-12245	1660 W ANAHEIM ST	90731	15	030B197    12	7412022010		Harbor	Wilmington - Harbor City		YES	9800.15	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM	07/31/2013 12:00:00 AM		Permit Finaled	03/04/2015 12:00:00 AM	ADDRESS	33.77884	-118.29327	Plan chcek power. New propane transport pump and analyzer for transported propane quality control equipment.  Installation in hazardous area.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77120	19041-10000-41410	16022 W MEADOWCREST ROAD	91403	5	162B141   494	2280019025	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1415.00	Electrical	Electrical	1 or 2 Family Dwelling			10/11/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.13653	-118.48241	$0 permit fee due to AB1414 [E-PLAN] PV1. REPLACING EXISTING ROOFTOP SOLAR SYSTEM WITH NEW SYSTEM CONSIST OF 53 AC MODULES (SUNPOWER 370) WITH 53 INTERNAL MICROINVERTERS (ENPHASE IQ7X). SYSTEM SIZE IS 19.61 KWdc AND 16.7KWac CONNECTED TO AN EXISTING 400A SERVISE	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77121	13041-10000-22960	4619 N LEMONA AVE	91403	4	168B145   858	2264015029	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			08/22/2013 12:00:00 AM	01/13/2014 12:00:00 AM		Permit Finaled	04/23/2014 12:00:00 AM	ADDRESS	34.15432	-118.45976	ROOF-MOUNTED INSTALLATION SOLAR ARRAY, INTERCONNECTING WITH MAIN PANEL. SYSTEM SIZED AT 5.75 KW IN A 2-STORY HOUSE. 23 MODULES: TRINA SOLAR #TSM-250PC05/PA05.181 INVERTER: POWER-ONE #AURORA PVI-5000-OUTD-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77122	10041-10000-21424	625 S BIXEL ST	90017	1	130-5A207  30	5143024008	CW	Central	Westlake	Downtown Los Angeles	YES	2092.00	Electrical	Electrical	Public Safety Only			10/27/2010 12:00:00 AM	10/27/2010 12:00:00 AM		Permit Finaled	09/07/2011 12:00:00 AM	ADDRESS	34.05322	-118.26286	NEW FIRE WARNING SYSTEM FOR A LOW INCOME HOUSING BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77123	16041-20000-23999	4735 N SEPULVEDA BLVD	91403	4	168B145   607	2264001043	C2-1L, R4-2L, [T][Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Apartment			07/08/2016 12:00:00 AM	01/12/2017 12:00:00 AM		Permit Finaled	02/23/2018 12:00:00 AM	ADDRESS	34.15623	-118.46637	Remodeling of (E) 236-unit apartment first floor common areas and elevator lobbies.  Plan check for energy.   10,735 sq ft	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77124	16041-10000-11639	243 S SAN PEDRO ST	90012	14	129A213   469	5161024***	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM			PC Info Complete	04/11/2016 12:00:00 AM	ADDRESS	34.04832	-118.24246	TENANT IMPROVEMENT FOR (E) RESTAURANT. PC FOR T-24 ONLY, TOTAL AREA: 1,935 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77125	16041-10000-42030	5750 W WILSHIRE BLVD 1ST FLR	90036	4	135B177   575	5089008031	QC4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			11/30/2016 12:00:00 AM			PC Approved	12/16/2016 12:00:00 AM	ADDRESS	34.06227	-118.3542	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING OFFICE SPACE ON THE GROUND FLOOR. NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 975 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77126	14041-10003-14728	15963 W STRATHERN ST	91406	6	189B141    23	2206005021	M2-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1274.00	Electrical	Electrical	Commercial			09/16/2014 12:00:00 AM			Corrections Issued	09/16/2014 12:00:00 AM	ADDRESS	34.21581	-118.48145	installing two 1500 kw  this needs fault , load study and sequence of load shedding.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77127	15041-10000-16353	1977 W BLAKE AVE	90039	13	148-5A213 260	5442010021	[Q]CM-1VL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			05/28/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	06/24/2015 12:00:00 AM	ADDRESS	34.10061	-118.24395	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 11392 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77128	17041-10000-28612	417 W PICO BLVD	90015	14	126A207   155	5139022018	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/14/2017 12:00:00 AM	08/14/2017 12:00:00 AM		Permit Finaled	04/25/2018 12:00:00 AM	ADDRESS	34.03928	-118.26478	Plan check for T24 only, install new lightings in the existing dry cleaning space using existing circuit, emergency lights for MES are existing and is not part if this scope. Total area 1,900 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77129	17041-10000-17090	333 S GRAND AVE STE# 3570	90071	14	130-5A211  12	5151015012	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			05/22/2017 12:00:00 AM	07/19/2017 12:00:00 AM		Permit Finaled	07/21/2017 12:00:00 AM	ADDRESS	34.05271	-118.25179	TI IN SUITE 3570. PC FOR T24 ENERGY ONLY. OFFICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77130	17041-20001-16581	4023 N ROCK HAMPTON DR	91356	3	162B125    30	2184054010	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			05/17/2017 12:00:00 AM			PC Approved	06/09/2017 12:00:00 AM	ADDRESS	34.14425	-118.53674	Expedite fee.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77131	18041-10001-32050	11725 W SUNSET BLVD	90049	11	135B145   561	4402009016	R3-1	West Los Angeles	Brentwood - Pacific Palisades			2623.02	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	04/17/2019 12:00:00 AM	ADDRESS	34.06488	-118.47066	Supplement to an approved set for fire alarm (E# 18041-10000-32050). Change under delta X. changes includes adding 7 FA devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77132	10041-10000-13624	106 W MANCHESTER AVE UNIT 3	90003	8	097-5A203 332	6040012027	[Q]C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2402.00	Electrical	Electrical	Commercial			07/15/2010 12:00:00 AM	07/21/2010 12:00:00 AM		Permit Finaled	09/09/2010 12:00:00 AM	ADDRESS	33.95993	-118.2743	CHANGE PORTION OF EXISTING BULIDING FROM DRY CLEANER TO BEAUTY PARLOR ; PROPOSED NEW 4 SPA PEDICURES; 4 MANICURES AND 1 SAUNA ROOM (NO CHANGE IN PARKING)   T24 lighting plan check only for remodeled space.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77133	15041-10000-04759	4833 W FOUNTAIN AVE	90027	13	147B197  1082	5543017018	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	02/18/2015 12:00:00 AM	PIN	34.09558862	-118.29426536	Plan check for Titlt 24 only. Total area: 764 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77134	17041-20001-34917	19550 W CANTARA ST	91335	3	192B117   913	2105002008	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2017 12:00:00 AM			PC Approved	10/09/2017 12:00:00 AM	ADDRESS	34.21901	-118.55965	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.12kW ungrounded system [(2) 6kW]. (60) 265W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77135	17041-10002-01942	12121 W VICTORY BLVD	91606	2	180B165   593	2322006036	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			06/26/2018 12:00:00 AM	08/14/2018 12:00:00 AM		Issued	08/14/2018 12:00:00 AM	ADDRESS	34.18684	-118.3977	DELTA 8 CHANGES TO APPROVED PLANS. <<<CHANGES INCLUDE REVISING AVAILABLE FAULT CURRENT TO DISTRIBUTION EQUIPMENT, REVISING AIC RATINGS, REVISING PANEL SCHEDULES, REVISING LIGHTING FLOOR PLANS, AND REVISING TITLE 24 CALCULATIONS.>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77136	16041-10002-28548	5411 N ETIWANDA AVE	91356	3	171B125    10	2160009024	C2-1L, P-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			06/19/2018 12:00:00 AM			Corrections Issued	06/19/2018 12:00:00 AM	ADDRESS	34.16935	-118.53104	NEW PARKING STRUCTURE. FULL PC FOR POWER AND ENERGY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77137	15041-10000-30846	10101 W WILSHIRE BLVD	90024	5	138B157     7	4359018***	A1-1XL	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	08/03/2016 12:00:00 AM	ADDRESS	34.06725	-118.41704	install new fire alarm system for los angeles country club. 339 fire alarm device and one fire alarm panel and one control panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77138	14041-20000-22816	22315 W NEEDLES ST	91311	12	201B101   355	2727006037	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.37	Electrical	Electrical	1 or 2 Family Dwelling			08/21/2014 12:00:00 AM	08/22/2014 12:00:00 AM		Permit Finaled	10/15/2014 12:00:00 AM	ADDRESS	34.24676	-118.61312	PV1 SFD. USING CENTRAL TRANSFORMERLESS INVERTER, STANDARD PLAN. USING POWER OPTIMIZERS. 24 MODULES.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77139	15041-20000-10702	14602 W GREENLEAF ST	91403	4	165A149   233	2276017001	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			04/10/2015 12:00:00 AM			PC Approved	04/10/2015 12:00:00 AM	ADDRESS	34.14859	-118.45241	Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (18) modules with (18) dc/dc converters. NOTE: Permit was originally pulled for this job under application number 15041-20000-07913. There was a change in the system (inverter is now tying into a distribution panel and before it was tying straight into the main service panel). This application if for plan check only. Existing permit will remain.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77140	10041-20000-21800	2000 N HIGHLAND AVE	90068	4	150A185   111	5575024011	[Q]R4-1VL	Central	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	Apartment			11/02/2010 12:00:00 AM			Corrections Issued	12/30/2010 12:00:00 AM	ADDRESS	34.10679	-118.33728	Plan check for new electrical system upgrade to 800A service for existing apartment building. All loads and wiring in dwelling units are existing to remain	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77141	19041-30000-33144	2049 S CENTURY PARK EAST 40TH FLR-41ST FLR	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	08/22/2019 12:00:00 AM		Permit Finaled	11/22/2019 12:00:00 AM	ADDRESS	34.05903	-118.41293	Energy pc only for conference room and board room, reflected ceiling plan and new mill works in 40th floor. area of scope 1779sf.building permit # 19016-10000-04331	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77142	18041-20000-45878	3933 N DIXIE CANYON AVE	91423	4	162B157   432	2373020012	R1-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	YES	1417.00	Electrical	Electrical	1 or 2 Family Dwelling			12/03/2018 12:00:00 AM	12/11/2018 12:00:00 AM		Permit Finaled	03/21/2019 12:00:00 AM	ADDRESS	34.14155	-118.42412	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 49 MODULES WITH OPTIMIZERS AND TWO CENTRAL INVERTERS. TOTAL SYSTEM SIZE 15.2KWAC/ 16.17 KWDCINCLUDING NEW LOAD CENTER.Note: $0.00 permit fee due to CA Senate Bill 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77143	13041-10001-00807	1127 W WILSHIRE BLVD	90017	1	130-5A207  29	5143023019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/14/2014 12:00:00 AM			PC Info Complete	04/15/2014 12:00:00 AM	ADDRESS	34.05287	-118.26415	Surgical center - power and energy.  Change of occupancy from a B occupancy to an I-2.1.((((((    3-14-2014  inspector reffered customer to plan check for the changes.)))))))))))))))))).  Delat 3 only	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77144	19041-30000-52036	6400 N OWENSMOUTH AVE UNIT#B	91367	3	180B105    64	2146005027	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/19/2019 12:00:00 AM		Permit Finaled	01/05/2021 12:00:00 AM	ADDRESS	34.18653	-118.6013	PLAN CHECK FOR ENERGY ONLY, SCOPE OF WORK IS NEW LIGHTING, CIRCUITS, AND POWER. NOTE PARTIAL PERMITS HAVE BEEN PULLED UNDER 19041-30000-42219. TOTAL AFFCTED AREA IS 4257 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77145	18041-10001-47323	7945 W LULU GLEN DR	90046	4	156B173   449	5570029002	RE11-1-HCR	South Valley	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			12/13/2018 12:00:00 AM			PC Approved	01/16/2019 12:00:00 AM	ADDRESS	34.12227	-118.37004	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.2KWdc / 11.40KWac.(40)MODULES-Q.PEAK.G4.1 305(40)OPTIMIZERS-SOLAREDGE P320W(1)INVERTER-SOLAREDGE SE11400A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77146	12041-10000-24821	22941 W VENTURA BLVD	91367	3	171B097   519	2042018020	C4-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		9304.01	Electrical	Electrical	Commercial			10/17/2012 12:00:00 AM			PC Approved	10/17/2012 12:00:00 AM	PIN	34.16530057	-118.62665459	PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING FOR TENANT IMPROVEMENT TO EXISTING RESTAURANT;  UNIT A .	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77147	18041-10000-17841	316 W 7TH ST	90731	15	015B201   168	7455012017	CM-2-CDO	Harbor	San Pedro	Central San Pedro		2962.20	Electrical	Electrical	Commercial			05/15/2018 12:00:00 AM	05/15/2018 12:00:00 AM		Permit Finaled	06/28/2018 12:00:00 AM	ADDRESS	33.73797	-118.2839	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77148	10041-10001-04813	2240 W WASHINGTON BLVD	90018	10	126B193   951	5073030044	[Q]C2-1-O	South Los Angeles	South Los Angeles	Untd Nghbrhds of Hstrc Arlington Hghts/W Adam		2214.00	Electrical	Electrical	Commercial			04/12/2010 12:00:00 AM	04/20/2010 12:00:00 AM		Permit Finaled	07/20/2010 12:00:00 AM	ADDRESS	34.03973	-118.31039	Originally, plan chk for Title 24 was approved  on 10041-10000-04813 as the service was to be 400A. the service size has been changed to 600A requiring this full plan chk.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77149	19041-10000-02780	2801 N FIGUEROA ST	90065	1	142-5A219 104	5446010018	UC(CA)-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1853.20	Electrical	Electrical	Commercial			01/23/2019 12:00:00 AM	01/24/2019 12:00:00 AM		Permit Finaled	03/12/2019 12:00:00 AM	ADDRESS	34.08501	-118.22118	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77150	13041-20000-14183	2027 S STONER AVE	90025	11	123B149   274	4262032901	PF-1XL	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			05/31/2013 12:00:00 AM	07/02/2013 12:00:00 AM		Permit Finaled	10/17/2014 12:00:00 AM	ADDRESS	34.03582	-118.4508	NEW CONSTRUCTION OF NATURAL GAS FUELING FACILITY. PC FOR POWER SYSTEM. CONTROL OF HAZARDOUS MATERIALS. ADDITIONAL PC HOURS HAVE BEEN ADDED. NEW OUTDOOR LIGHTING TO BE EXPEMT. INDUSTRIAL SITE. New 1600 amp SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77151	18041-10000-10012	7050 N VALJEAN AVE	91406	6	183B141   248	2224010034	(Q)M1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	Commercial			03/20/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Issued	03/20/2018 12:00:00 AM	ADDRESS	34.19905	-118.4857	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77152	16041-20000-12637	1320 S KENISTON AVE	90019	10	129B185   598	5083024018	R2-1-O	Central	Wilshire	Olympic Park		2172.00	Electrical	Electrical	1 or 2 Family Dwelling			04/12/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	05/26/2016 12:00:00 AM	ADDRESS	34.05053	-118.33866	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 3KW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77153	15041-10000-43492	357 N FORDYCE ROAD	90049	11	138B141   395	4429019033	RE20-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			12/24/2015 12:00:00 AM	12/24/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.07266	-118.47174	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 12KWAC. 52 MODULES AND 2 INVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77154	18041-10002-31409	230 S GAFFEY ST	90731	15	018B197  1468	7451016013	C2-1VL-CPIO	Harbor	San Pedro	Central San Pedro		2966.00	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM			PC Approved	01/09/2019 12:00:00 AM	ADDRESS	33.74186	-118.29212	SUPPLEMENTAL TO APPROVED SET DELTA 4 ONLY CHANGE FROM 300W TO 305W SOLAR PANEL SAME MANUFACTOR. NEW DC SIZE: 15.25KW	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77155	16041-20001-21970	1383 N MURCHISON ST	90033	14	132A227    19	5202011050	(T)(Q)C1-1VL	East Los Angeles	Northeast Los Angeles			2031.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.05771	-118.197	((9/8/2016))changes to an approved set of plans.  change light fixtures from led to fluorescent.  plan check for energy and em lighting only.  changes noted delta A. this is plan check only.TI TO AN EXISTING COMMERCIAL BUILDING.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG ONLY. TOTAL SQUARE FOOTAGE 1182  CORE AND SHELL APPROVED UNDER APPLICATION NUMBER 13041-10000-19886	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77156	18041-20000-07780	20650 W CHESTNUT CIR (#336)	91326	12	216B109    14	2701001040	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			03/02/2018 12:00:00 AM	03/02/2018 12:00:00 AM		Permit Finaled	11/15/2018 12:00:00 AM	ADDRESS	34.29342	-118.58444	PV1.  Install 2.88 kW roof mounted grid tied PV system.  (9) AC modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77157	15041-20001-39000	7700 W SUNSET BLVD	90046	4	147B177  1007	5551023023	C1-1VL	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			11/18/2015 12:00:00 AM			Reviewed by Supervisor	12/01/2015 12:00:00 AM	ADDRESS	34.09788	-118.35739	RSES expedited plan check fee per applicant.  (((PV2.  Install 143.64 kW roof-mounted, utility-interactive PV system for 2-story commercial office building.  (504) Solarworld 285W modules w/ (12) SunnyBoy 11000TL-US-12.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77158	14041-10001-23566	13907 W DAVENTRY ST	91331	7	207B153   325	2618003020	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			09/11/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.26558	-118.43589	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 13.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(50) MODULES: KYOCERA KD255GX-LFB3(2) INVERTER: SOLAREDGE SE6000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77159	18041-20000-19208	19551 W CANTARA ST	91335	3	192B117   839	2105001019	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1316.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM	05/23/2018 12:00:00 AM		Issued	05/23/2018 12:00:00 AM	ADDRESS	34.21924	-118.55962	Plan check for a PV1 roof-mounted PV system. System size is 6 kWac and consists of (1) inverter and (22) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77160	17041-10001-31132	12964 W PANAMA ST BLDG 4	90066	11	105B157   569	4223008010	M1-1, M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/30/2019 12:00:00 AM		Permit Closed	06/08/2020 12:00:00 AM	ADDRESS	33.9839	-118.42804	Revision to approved set of plan to reduce inverter's size from 17 kW to 12.5 kW; add (2) sump pump in (E) panel HPS; Revised service load calculation per latest connected  load.  All changes are noted as Delta-1. <<PC FOR POWER AND ENERGY FOR A NEW  4-STORY PARKING STRUCTURE (BUILDING 4). SCOPE INCLUDES NEW 1200A 277/480 DISTRIBUTION BOARD, SERVICE IS EXISTING UNDER SEPARATE PLAN/PERMIT.  NEW PANELS LIGHTS AND EQUIPMENT.   TOTAL AFFECTED AREA 167749 SQ.FT>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77161	16041-10000-08670	510 S BROADWAY	90013	14	129A211   108	5149034002	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/11/2016 12:00:00 AM	04/05/2017 12:00:00 AM		Permit Finaled	05/09/2018 12:00:00 AM	ADDRESS	34.04767	-118.25088	PC for power and energy to an exiting 5 story building, core and shell, plus basement used for offices. New 600 A distribution board.  Total sq ft = 37,927 sq ft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77162	12041-20000-27052	4253 N COLDWATER CANYON AVE	91604	2	165B161  1098	2375019041	C1.5-1VL, RD1.5-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1435.00	Electrical	Electrical	Commercial			11/09/2012 12:00:00 AM			PC Approved	11/09/2012 12:00:00 AM	ADDRESS	34.1469	-118.414	Plan check for energy and emergency lighting. two-story office. 3697 indoor sqft, 3127 outdoor sqft. Permit has already been pulled under 12041-20000-23638.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77163	19041-20000-09012	10342 N LOUISE AVE	91344	12	204B133    94	2695015009	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1113.01	Electrical	Electrical	1 or 2 Family Dwelling			03/13/2019 12:00:00 AM	03/13/2019 12:00:00 AM		Permit Finaled	05/24/2019 12:00:00 AM	ADDRESS	34.25893	-118.51089	Plan check for a PV1 roof-mounted PV system. System size is 4.8 kWdc/4.301 kWac-CEC and consists of (1) 7.6 kWac rated inverter and (16) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77164	11041-20003-14848	15643 W WYANDOTTE ST	91406	6	186B141   721	2206029016	(T)(Q)R3-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			04/03/2013 12:00:00 AM			PC Approved	04/03/2013 12:00:00 AM	ADDRESS	34.20311	-118.47409	Changes to previously approved set of plans. Service conductors for MS-1 changed to copper from aluminum.Changes to approved set of plans. Air-conditioners and fan-coils downsized. Air-conditioners now equipped with 25A breakers. New 300A main breaker for MS-1, MS-1 service entrance conductors are now 500kcmil Al THW insulation.Plan check power and energy for new 3-story 19 unit apartment bldg. 1000A service supplying bldg. Modification to seperate fire system has been filed	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77165	19041-20001-25787	876 N ILIFF ST	90272	11	129B129   938	4423025016	R1V1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	1 or 2 Family Dwelling			09/10/2019 12:00:00 AM			PC Approved	09/10/2019 12:00:00 AM	ADDRESS	34.04568	-118.51856	CHANGES TO APPROVED SET DELTA 1 ONLY RELOCATION OF SUBPANEL AND GATEWAY AND ADD NEW AC DISCONNECTS.<<<Plan check for a PV1 roof-mounted PV system. System size is 8.45 kWdc/7.584 kWac and consists of (26) modules, (26) micro-inverters, (2) load centers, and (2) battery back-up units.>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77166	14041-10001-02688	1534 W 213TH ST	90501	15	051B193   479	7349018010	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.01	Electrical	Electrical	1 or 2 Family Dwelling			01/30/2014 12:00:00 AM			PC Approved	03/12/2014 12:00:00 AM	ADDRESS	33.83536	-118.30507	Expedited RSES plan check per applicant request.{{PV1, Install 4.25 KW DC roof-mounted solar array on a two story house, interconnect with existing service panel.(1) Transformerless inverter: SOLAREDGE SE3800A-US-ZB-U.(17) Modules: TRINA SOLAR TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77167	17041-10001-05467	10250 W SANTA MONICA BLVD # 2970	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			06/08/2017 12:00:00 AM			PC Approved	06/08/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	[This is plan check only for Disney Store] Changes to approved set noted as Delta 4: add light fixtures in vestibule, revise load on panel LA, revise T24 forms and floor plan accordingly.  Permit is covered under master 17041-10000-05467	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77168	10041-20000-25507	3620 S VERMONT AVE 1st, 3rd-4th floor	90089	8	120B197   929	5039002030	[Q]R4-1, [Q]R4-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			12/23/2010 12:00:00 AM	05/25/2011 12:00:00 AM		Permit Finaled	08/18/2011 12:00:00 AM	ADDRESS	34.02213	-118.29133	TI at USC Kaprielian Hall on 1st, 3rd, and 4th floor. Plan check T24 energy for general and emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77169	16041-20000-41368	5025 E YORK BLVD	90042	14	156A225   265	5476016025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1834.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	02/08/2017 12:00:00 AM		Permit Finaled	07/26/2017 12:00:00 AM	ADDRESS	34.12143	-118.20595	PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR RETAIL COFFEE SHOP. 1420 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77170	19041-20000-25337	10621 N FULLBRIGHT AVE pv1	91311	12	207B113   138	2707018016	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			07/02/2019 12:00:00 AM	07/02/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.26291	-118.57694	pv1install roof mounted pv system sized 12.5KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77171	19041-20001-28479	10415 W CUMPSTON ST	91601	2	174B177   823	2417010012	R1-1	South Valley	North Hollywood - Valley Village	NoHo		1253.10	Electrical	Electrical	1 or 2 Family Dwelling			08/08/2019 12:00:00 AM			PC Approved	08/08/2019 12:00:00 AM	ADDRESS	34.17042	-118.35761	08-08-2019 Changes to an approved set of plan, Changes include relocate equipment PV system. All Change has been cloudedPlan check onlyFees $22.29 due to California Senate Bill 1222  and AB 1414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77172	19041-20000-50627	1438 N GOWER ST	90028	13	147A189   229	5545013404	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/09/2019 12:00:00 AM	12/09/2019 12:00:00 AM		Issued	12/09/2019 12:00:00 AM	ADDRESS	34.09714	-118.32212	T24 PLAN CHECK FOR LIGHTS ONLY, TOTAL SQUARE FOOTAGE = 99,306 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77173	15041-10000-36626	222 N MARIPOSA AVE	90004	13	138B197   380	5518011002	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2112.01	Electrical	Electrical	Commercial			11/02/2015 12:00:00 AM			PC Approved	11/02/2015 12:00:00 AM	ADDRESS	34.07605	-118.29926	T-24, CORE AND SHELL TO A NEW OFFICE TYPE BUILDING. SERVICE SIZE IS 400AMP. SCOPE INCLUDE LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 3360	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77174	11041-20000-13060	2310 E ALCAZAR ST	90033	14	135A227    99	5202002020	[Q]C2-1	East Los Angeles	Northeast Los Angeles			2033.00	Electrical	Electrical	Commercial			06/23/2011 12:00:00 AM	11/01/2011 12:00:00 AM		Permit Finaled	08/07/2012 12:00:00 AM	ADDRESS	34.06251	-118.19887	PLAN CHECK POWER AND ENERGY TENANT IMPROVEMENT AT 1ST FLOOR MEDICAL CLINIC AND 2ND FLOOR MEDICAL OFFICE. EXISTING 1200A SERVICE. NO PLAN REVIEWED FOR OSHPD III.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77175	19041-10000-11157	1745 N GRAMERCY PL	90028	13	148-5A193  41	5544002031	R3-1	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Commercial			03/28/2019 12:00:00 AM	03/28/2019 12:00:00 AM		Permit Finaled	09/18/2019 12:00:00 AM	ADDRESS	34.10311	-118.31242	INSTALATION OF FIRE PUMP AND JOCKEY PUMP AT A SENIOR LIVING APARTMENT BUILDING REFERENCE 14041-10000-34949.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77176	12041-20001-19376	1537 N NORFOLK ST	90033	14	133-5A225   5	5202004030	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights	YES	2033.00	Electrical	Electrical	Commercial			01/24/2014 12:00:00 AM			Reviewed by Supervisor	02/07/2014 12:00:00 AM	ADDRESS	34.06138	-118.20223	((((THIS PLAN CHECK COVERS COORDINATION STUDY ONLY))))PLAN CHECK FOR USC DOHENY EYE INSTITUTE 3000A SWITCHBOARD AND 600A DISTRIBUTION BOARD REPLACEMENT. NO CHANGE IN LOADS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77177	18041-20000-31574	14630 W SATICOY ST	91405	6	186B149   219	2218003032	R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			08/20/2018 12:00:00 AM	02/27/2019 12:00:00 AM		Permit Finaled	05/29/2019 12:00:00 AM	ADDRESS	34.20831	-118.45189	PV2.  Install 28.275 kW roof mounted grid tied PV system.  (87) modules with (2) 11.4 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77178	14041-10000-34570	5057 W WASHINGTON BLVD	90019	10	126B181   889	5067016014	C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			12/12/2014 12:00:00 AM	12/29/2014 12:00:00 AM		Permit Finaled	01/20/2015 12:00:00 AM	PIN	34.04114399	-118.34989775	Plan check for energy Title 24 total area: 1260SQFT for Dallar Tree	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77179	17041-10000-43575	19515 S VERMONT AVE	90502	15	057B197    23	7351034023	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			12/04/2017 12:00:00 AM			PC Approved	12/04/2017 12:00:00 AM	ADDRESS	33.85325	-118.29073	VOID, PC WIll BE REDONE ON A NEW APP#PC FOR T-24, INSTALL (1) NEW WALK IN COOLER  AND  (1)  NEW WALK IN FREEZER IN WAREHOUSE, NOT PRE FAB LIGHTING, CONTRACTOR TO INSTALL NEW LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77180	10041-10000-07430	7060 W HOLLYWOOD BLVD 1st Floor	90028	13	147B181   205	5548007***	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			04/22/2010 12:00:00 AM	05/04/2010 12:00:00 AM		Permit Finaled	09/29/2010 12:00:00 AM	ADDRESS	34.10137	-118.34379	Plan check T-24 Energy for a remodel for a portion of the 1st floor.  See rooms 100, 102, 103, 105.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77181	13041-10000-03660	8609 N RUBIO AVE	91343	12	195B137   933	2689017026	RE11-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1173.03	Electrical	Electrical	1 or 2 Family Dwelling			02/12/2013 12:00:00 AM	02/12/2013 12:00:00 AM		Permit Finaled	04/12/2013 12:00:00 AM	ADDRESS	34.22709	-118.49664	PV1 ROOF MOUNTED SOLAR INSTALLATION ON A SINGLE STORY HOUSE USING STANDARD PLAN. [INVERTER: FRONIUS # IG PLUS V10.0 |||| MODULES: TRINA # TSM-245 PA05] SYSTEM SIE IS 11.76 KW.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77182	19041-10000-52956	925 W 8TH ST	90017	14	129A207   337	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/23/2019 12:00:00 AM	12/30/2019 12:00:00 AM		Issued	12/30/2019 12:00:00 AM	ADDRESS	34.04862	-118.26216	T.I. PC FOR T-24 ENERGY ONLY. SCOPE INCLUDES NEW 75KVA TRANSFORMER, EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS.  TOTAL  AFFEECTED AREA 19895sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77183	17041-10001-00237	4415 S CENTRAL AVE	90011	9	112-5A209  93	5108028023	[Q]C2-1	South Los Angeles	Southeast Los Angeles			2286.00	Electrical	Electrical	Commercial			09/13/2017 12:00:00 AM	09/13/2017 12:00:00 AM		Permit Finaled	09/15/2017 12:00:00 AM	ADDRESS	34.00344	-118.25677	PC FOR ADDITION OF SCOPE OF WORK. ADDITION SCOPE NOTED DELTA 2 ON PLANS. ADDED BACK AREA. SCOPE INCLUDE LIGHITNG. PERMIT FOR ADDED WORK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77184	15041-10000-41835	4091 S REDWOOD AVE 1-67	90292	11	108B153   893	4230006032	CM(GM)-2D-CA	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2754.00	Electrical	Electrical	Commercial			12/11/2015 12:00:00 AM	12/30/2015 12:00:00 AM		Permit Finaled	11/02/2016 12:00:00 AM	PIN	33.99096225	-118.44116852	Installation of a new fire alarm system to a 67 unit five story apartment (1) FA panel, (4) Control panel, (1) communication panel, (226) FA devices.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77185	18041-20000-16002	4754 N AMIGO PL	91356	3	168B125   161	2176017003	RA-1	South Valley	Encino - Tarzana	Tarzana	Yes	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			05/01/2018 12:00:00 AM	05/01/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	34.15926	-118.53788	Plan check for PV roof mounted system, System size: 16.6 kW with 59 modules and 3 inveters(3.8kW, 5.2kW and 7.6kW) on SFD.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77186	19041-10000-35804	1051 S CORNING ST 1-19	90035	5	132B173   586	4332025026	[Q]R3-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Apartment			09/10/2019 12:00:00 AM	07/23/2020 12:00:00 AM		Issued	07/23/2020 12:00:00 AM	ADDRESS	34.05786	-118.37754	NEW 5 STORY TYPE III-A, 19 UNITS APARTMENT BUILDING. SCOPE OF WORK INCLUDES NEW 1000 AMP SERVICE, 120V/208V, 3PHASE. NEW LIGTING AND POWER, TOTAL SQ. FT. 47245.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77187	15041-20000-43396	7355 N BALBOA BLVD	91406	6	186B133   803	2227001050	(Q)RD1.5-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	Apartment			01/15/2016 12:00:00 AM	04/20/2016 12:00:00 AM		Permit Finaled	05/23/2016 12:00:00 AM	ADDRESS	34.20442	-118.50145	Plan check for PV roof mount system on Appartmet building. System size: 10 kWac with 32 modules and (1) 3-phase 10.0 kW inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77188	18041-20000-48876	5359 N GENESTA AVE	91316	5	171B133    42	2258028004	RA-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2018 12:00:00 AM	12/27/2018 12:00:00 AM		Permit Finaled	02/26/2019 12:00:00 AM	ADDRESS	34.1689	-118.50347	pv1install roof mounted pv system sized 15.3KW AC interconnected with msp.19.6 KW DC system	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77189	17041-10000-21260	6950 N TUJUNGA AVE	91605	2	183B173   168	2319005002	M2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1232.06	Electrical	Electrical	Commercial			06/23/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	07/12/2017 12:00:00 AM	ADDRESS	34.19678	-118.37888	T24 ONLY - REPLACEMENT OF EXISTING LIGHT FIXTURES WITH (65) LED FIXTURES.  TOTAL AFFECTED AREA =   175600 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77190	11041-10000-14790	4274 S MAIN ST	90011	9	114A205   310	5113031031	C2-1VL	South Los Angeles	Southeast Los Angeles			2284.20	Electrical	Electrical	Commercial			07/15/2011 12:00:00 AM	02/28/2012 12:00:00 AM		Permit Finaled	06/21/2012 12:00:00 AM	PIN	34.00583482	-118.27362194	CHANGE OF USE FROM MINI-MARKET TO LAUNDRY MAT.  NEW 800A SWITCHBOARD, PANELS, CIRCUITS.  PLAN CHECK FOR ENERGY AND POWER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77191	16041-10000-17065	13210 W HARDING ST	91342	7	222B157   494	2525002043	RA-1	North Valley	Sylmar	Sylmar		1061.13	Electrical	Electrical	1 or 2 Family Dwelling			05/16/2016 12:00:00 AM	06/07/2016 12:00:00 AM		Permit Finaled	10/18/2016 12:00:00 AM	ADDRESS	34.30286	-118.42094	PV1, INSTALL NEW 9.435 KW DC GROUND MOUNTD SOLAR ARRAY IN A SINGLE FAMILY HOUSE.(37) MODULES: CANADIAN SOLAR CS6P-255P(1) INVERTER : SOLAREDGE SE7600A-US	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77192	17041-20000-30164	16143 W WATERMAN DR	91406	6	189B137    27	2205004902	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			08/23/2017 12:00:00 AM	10/27/2017 12:00:00 AM		Permit Finaled	07/11/2018 12:00:00 AM	ADDRESS	34.21445	-118.48429	Plan check for a PV2 roof-mounted and ground-mounted feed-in tariff PV system. Total system size is 400 kWac. Roof-mounted portion of the system is 276 kWac and consists of (5) inverters, (860) modules, and (1) load centers.Note: $0.00 permit fee due to CA Senate Bill 1222. Ground-mounted portion of the system has application number 17041-20000-30167 and has building application number 17010-30000-03239.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77193	16041-20000-02323	9805 W LA TUNA CANYON ROAD	91352	7	198B181    80	2544017007	A2-1-K	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District	YES	1021.07	Electrical	Electrical	1 or 2 Family Dwelling			01/21/2016 12:00:00 AM	01/21/2016 12:00:00 AM		Permit Finaled	03/08/2016 12:00:00 AM	ADDRESS	34.23514	-118.34434	PV1. Install roof mounted PV system sized 3 kW. Interconnected with main service panel. Standard Plan in use.(15) Yingli YL255P Modules(1) ABB PVI 3.0 Inverters	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77194	10041-20000-16130	701 N STONE CANYON ROAD TEMP	90077	5	141B149    28	4370004039	[T][Q]R4-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2621.00	Electrical	Electrical	Commercial			08/17/2010 12:00:00 AM	10/14/2010 12:00:00 AM		Permit Closed	10/06/2011 12:00:00 AM	ADDRESS	34.08578	-118.44515	Plan check for temp electrical 600A power for construction.  Loads will be future application.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77195	11041-10001-25537	10201 W PICO BLVD BLDG 29	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			04/26/2012 12:00:00 AM			PC Approved	04/26/2012 12:00:00 AM	PIN	34.05182951	-118.41257696	REVISION TO APPROVED PLANS. MARKED DELTA 6 ON PLANS. REMOVE ADDITIONAL AC DISCONNECT. COMBINED LADWP AC DISCONNECT WITH BUILDING PV AC DISCONNECT. SHALL NOT BE SEALED. ********PLAN CHECK FOR NEW ROOF MOUNTED 231.8KW PHOTOVOLTAIC SYSTEM ON FOX STUDIOS BUILDINGS #26 AND BUILDING #29. BUILDING #26 PERMIT UNDER #12041-10000-04678. SATCON INVERTER LOCATED IN BUILDING #29. 532 MODULES ON BUILDING #26 AND 434 MODULES ON BUILDING #29. (1 0F 2). SITE IN METHANE ZONE, NO WORK IN HAZARDOUS AREA.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77196	15041-20000-13181	112 E 22ND ST Bldg 9-10	90731	15	012B201   214	7440034901	[Q]M2-1	Harbor	Port of Los Angeles	Coastal San Pedro		9800.31	Electrical	Electrical	Commercial			05/12/2015 12:00:00 AM	07/08/2015 12:00:00 AM		Permit Finaled	11/02/2017 12:00:00 AM	ADDRESS	33.72783	-118.27968	$0 permit fee is due to State Senate Bill SB-1222.  PV2 commercial rooftop solar system. system utilizes 2 buildings. both buildings interconnect to a single service point. The solar system is a Feed in terrif. System directly sells electrical energy to utility company. This system is noted as a single 1.2MW DC system.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77197	13041-20000-18693	8000 W SUNSET BLVD Suite DIK	90046	4	147B177  1032	5554005069	[Q]C2-2D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			07/16/2013 12:00:00 AM			PC Approved	07/16/2013 12:00:00 AM	ADDRESS	34.09783	-118.36466	TI FOR EXISTING SPACE. CHANGE OF USE FROM YOGURT SHOP TO BEAUTY SALON. NEW CONNECTED LOAD < 400A. TOTAL SQRFT 1374. SCOPE OF WORK IN SUITE DIK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77198	18041-10000-19610	5533 S EA WAY	90094	11	102B157   295	4211022015	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM	06/01/2018 12:00:00 AM		Permit Closed	05/29/2020 12:00:00 AM	ADDRESS	33.97374	-118.42896	TEMPORARY CONSTRUCTION SERVICE AND ASSOCIATED EQUIPMENT	N	N	Appointment Plan Check	06/10/2024 12:00:00 AM
77199	16041-30000-35018	20870 W VENTURA BLVD	91364	3	171B109   105	2166028***	RA-1, RA-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	Commercial			10/04/2016 12:00:00 AM	10/04/2016 12:00:00 AM		Permit Finaled	10/19/2016 12:00:00 AM	ADDRESS	34.16612	-118.58755	Title 24 plan check only.  Remove outodoor HID fixtures and replace with new LED fixtures.  Total area = 61,385 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77200	17041-10007-00340	5101 N LANKERSHIM BLVD	91601	2	171B173   871	2353004023	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	09/03/2019 12:00:00 AM	ADDRESS	34.16326	-118.37388	"DELTA ""12"" CHANGES TO THE APPROVED PLANS FOR CHANGING THE SIZE OF THE FIRE PUMP FROM 25HP TO 30HP. Note: Mechanical Plan Check is required for changing the size of the Fire Pump.Full PC for power and energy. New mixed use housing complex -297 dwelling-unit 6 levels of apartment on top of on grade market (core and shell)  above 2 -level of type I construction parking garage.  Scope includes three new services/distribution boards(2500A & 1600A), new panels, new circuits, and new lights for two structures. Total affected area is 266331 Sq. Ft.  B#16010-10000-04268@@@@BUILDING COVERS TWO ADDRESSES:  5101 LANKERSHIM BLVD AND 5130 KLUMP AVE.@@@"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77201	19041-20000-22477	8360 N CANBY PL	91324	12	192B125   944	2786021021	(T)(Q)C2-1VL	North Valley	Northridge	Northridge South		1154.03	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2019 12:00:00 AM	06/12/2019 12:00:00 AM		Permit Finaled	04/14/2021 12:00:00 AM				PV1.  Install 2.8 kW roof mounted grid tied PV system for new home construction.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77202	16041-10000-06600	1165 N KINGSLEY DR	90029	13	144B193   492	5537010003	RD1.5-1XL	Central	Hollywood	East Hollywood		1911.20	Electrical	Electrical	Apartment			02/25/2016 12:00:00 AM	05/18/2016 12:00:00 AM		Permit Finaled	06/24/2016 12:00:00 AM	ADDRESS	34.09241	-118.3026	Upgrade Main service to 800A to (E) 3 units + (N) 4 unit apartments. PC for Power only. Note:(30) branch circuits are pulled under Permit# 15041-10000-40567Build. App. # 15014-10000-05170, 15016-10000-23223.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77203	18041-20000-00162	8231 W 3RD ST Unit C	90048	5	138B173   815	5511018025	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			01/03/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	03/21/2018 12:00:00 AM	ADDRESS	34.07272	-118.36914	Plan check for Title 24 only. Project site is an existing commercial tenant suite. Projet scope is a change of use from retail to gym/tenant improvement. Total lighting area = 1,983 sq. ft.Note: Building permit has been issued under 17016-20000-29792	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77204	11041-10000-24874	700 W WORLD WAY Terminal 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM	03/22/2012 12:00:00 AM		Permit Finaled	08/07/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	Plan check power only for concession stand upgrade for LAX Terminal 7. 800A board and 225KVA transformer. Concession stands future.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77205	16041-10000-41263	3345 W WILSHIRE BLVD	90010	10	132B197    22	5502028020	C4-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			11/23/2016 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	04/16/2019 12:00:00 AM	ADDRESS	34.06193	-118.2963	PC FOR POWER AND ENERGY.  ADAPTIVE REUSE CONVERSION OF A 12 STORY OFFICE BLDG TO 202 LIVE-WORK UNITS. 9 TYPICAL UNITS. EXISTING SERVICE.  TOTAL AREA  58292 SQ FT.     B#15016-10000-11808     Fire alarm variance has been completed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77206	17041-10000-41094	1723 W JAMES M. WOOD BLVD	90015	1	130-5A203 164	5142015009	C2-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/14/2017 12:00:00 AM		Issued	11/14/2017 12:00:00 AM	ADDRESS	34.05189	-118.27515	REPLACING OUTDOOR LUMINIRES WITH LED TYPEPLAN CHECK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77207	15041-10000-44014	12733 N DARYL AVE	91344	12	222B129   309	2608001025	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.41	Electrical	Electrical	1 or 2 Family Dwelling			12/31/2015 12:00:00 AM	01/15/2016 12:00:00 AM		Permit Expired	02/14/2018 12:00:00 AM	ADDRESS	34.3019	-118.51464	PERMIT FEE $0.00 BY STATE SENATE BILL NO. 1222PV1, INSTALL 11550 WDC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(66) MODULES:REC SOLR REC275TP(2) INVERTER: SOLAREDGE TECHNOLOGY SE 7600A-US 240V	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77208	12041-10000-04595	1020 S FIGUEROA ST	90015	14	127-5A207  71	5138012023	C2-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			02/29/2012 12:00:00 AM			PC Approved	03/14/2012 12:00:00 AM	ADDRESS	34.04442	-118.26422	T.I. to an existing upper & lower hotel lobby, and meeting rooms San Francisco 1 & San Francisco 2.  Change of lighting.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77209	19041-10001-21780	15303 W VENTURA BLVD 5TH FLR	91403	4	168B145   466	2264001045	[Q]C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			PC Approved	08/15/2019 12:00:00 AM	ADDRESS	34.15413	-118.46661	Changes to approved set/ inspector corrections. Scope of work is revision to lighting plan, showing the exit signs, and reflecting the emergency generator. Orginal permit has been pulled.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77210	17041-20000-44946	21800 W OXNARD ST Suite 790	91367	3	177B105    81	2146006046	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	01/31/2018 12:00:00 AM	ADDRESS	34.17898	-118.60253	Plan check for energy only. TI to office suite 790 in high rise building. New lighting (incl. emergency) - 3,778sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77211	18041-10001-26130	318 S LINCOLN BLVD 225	90291	11	111B145   642	4243016022	[Q]C2-1-CDO	West Los Angeles	Venice	Venice		2731.00	Electrical	Electrical	Commercial			07/24/2018 12:00:00 AM			Corrections Issued	07/24/2018 12:00:00 AM	ADDRESS	34.00111	-118.46697	PLAN CHECH FOR T24 FOR TI WITHIN EXISTING OFFICE SPACE - TOTAL AFFECTED AREA = 2455 SFORIGINAL PERMIT TI IN AN EXISTING OFFICE AREA ON 2ND FLOORT-24 ENERGY ONLY.BLDG PERMIT # __________________	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77212	12041-10001-14095	18121 W CHATSWORTH ST	91344	12	207B125   100	2715025055	(Q)C2-1L	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM	10/15/2012 12:00:00 AM		Issued	10/15/2012 12:00:00 AM	ADDRESS	34.2647	-118.52646	(((  changes to panel a, addition of transformer, and routing panel A1 and A2.)))))))))))))    T.I. to an existing Dental Space, building is not licensed by the state, NOT checked for OSHPD.  Full plan check for Power and Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77213	18041-10001-13264	10635 W WILSHIRE BLVD 1-46	90024	5	132B153    69	4360011003	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			07/02/2018 12:00:00 AM			PC Approved	07/02/2018 12:00:00 AM	ADDRESS	34.06138	-118.43484	(This is Plan check only, permit is covered under master #18041-10000-13264), Revision to approved set, scope includes replacing light fixture to reduce input wattage. T24 calculation is also revised accordingly.PLAN CHECK FOR TITLE 24 ONLY FOR TI WITHIN COMMON AREAS OF AN APPARTMENT COMPLEX(LOW RISE BUILDING). EMERGENCY LIGHTING SHALL BE PROVIDED BY INVERTER(90 MIN. MINIMUM)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77214	18041-30000-37527	7265 W MELROSE AVE	90046	5	141B181   541	5525012013	C4-1XL	Central	Hollywood	Mid City West		1920.01	Electrical	Electrical	Commercial			10/02/2018 12:00:00 AM	10/23/2018 12:00:00 AM		Permit Finaled	04/26/2019 12:00:00 AM	ADDRESS	34.08365	-118.348	Plan check for T24 only, TI to an existing commercial building.  adding new lighting new controls to new panels.  Total area: 1862 sq.ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77215	17041-20000-12001	3737 S BENTLEY AVE	90034	5	117B161   984	4252007041	R3-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2718.01	Electrical	Electrical	Commercial			04/13/2017 12:00:00 AM	06/23/2017 12:00:00 AM		Permit Finaled	10/23/2017 12:00:00 AM	ADDRESS	34.01482	-118.41685	PV2.  Install roof mounted PV system sized 14.4kW interconnected with MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77216	14041-20000-35844	914 S GRAND VIEW ST	90006	1	130-5A201  25	5136005022	R4-1	Central	Westlake	MacArthur Park		2095.10	Electrical	Electrical	Commercial			12/30/2014 12:00:00 AM	12/31/2014 12:00:00 AM		Permit Closed	09/06/2016 12:00:00 AM	ADDRESS	34.05365	-118.281	Change of serivce from underground to overhead. An addition of 2 AC units.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77217	13041-10000-20791	7857 W KYLE ST	91040	7	208-5A195 300	2556011040	R1-1-RFA	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1031.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2013 12:00:00 AM	08/05/2013 12:00:00 AM		Issued	08/05/2013 12:00:00 AM	ADDRESS	34.2648	-118.3046	PLAN CHECK FOR PV1 ROOR MOUNTED SOLAR INSTALLATION USING MICROINVETER STANDARD PLAN. SYSTEM SIZE IS 4.32 KW AC AND 5 KW DC. [INVERTER:  ENPHASE # M215-60-2LL-S22 |||| MODULE: REC # REC250PE]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77218	14041-10001-17727	6201 W HOLLYWOOD BLVD # 120	90028	13	148-5A189 350		[Q]R3-1XL, [T][Q]C4-2D-SN	Central	Hollywood	Hollywood United		1910.00	Electrical	Electrical	Commercial			01/13/2015 12:00:00 AM			PC Approved	01/13/2015 12:00:00 AM	ADDRESS	34.1018	-118.32461	Change to approved set by adding and removing circuits and equipment; note all changes are under delta-6 & 7 only.(((plan check for power and energy. BLDG#14014-10-02631:CHANGE OF USE FROM RETAIL TO RESTAURANT.  NEW 4050 SQ.FT. FULL SERVICE RESTAURANT IN EXISTING VACANT TENANT SPACE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77219	18041-10001-11912	333 S ALAMEDA ST UNIT#108	90013	14	127-5A215   7	5147001013	M2-2D-O	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			05/25/2018 12:00:00 AM			PC Approved	05/25/2018 12:00:00 AM	ADDRESS	34.04448	-118.23824	PC FOR CHANGES TO APPROVED SET TO REFLECTED FIELD INSTALL. ALL CHANGES UNDER DELTA 1.SCOPE INCLUDES REVISIONS TO CIRCUITS AND EQUIPMENT LOCATION.  PER APPLICANT REQUEST. THIS IS PLAN CHECK ONLY!PLANCHECK FOR T24 ENERGY.  T.I. (e) coffee shop. 255 SQFT.THIS IS PLAN CHECK ONLY!PERMIT UNDER 18041-10000-15471BUILDING PERMIT # 18016-30000-06811	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77220	19041-10000-03683	12457 N GLADSTONE AVE STE F	91342	7	219B161   235	2525018059	M1-1	North Valley	Sylmar	Sylmar		1061.12	Electrical	Electrical	Commercial			01/30/2019 12:00:00 AM	01/31/2019 12:00:00 AM		Issued	01/31/2019 12:00:00 AM	ADDRESS	34.29638	-118.41277	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77221	14041-10005-25267	8820 S BELFORD AVE	90045	11	096B169   869	4125012001	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Apartment			07/27/2017 12:00:00 AM	08/31/2017 12:00:00 AM		Permit Closed	05/20/2020 12:00:00 AM	ADDRESS	33.95637	-118.3838	CHANGES TO APPROVED SET OF PLANS. CHANGES TO DWELLING UNIT FLOOR PLANS, UPDATED METERING SECTIONS AND SIZING. PROVIDED UPDATED FLOOR PLAN TO REFLECT AS BUILT AND NEW CIRCUIT WIRING. 3 NEW PANELS AND ADDITIONAL CIRCUITS. ALL CHANGES NOTED ON PLANS DELTA 8. PERMIT TO BE ISSUED UNDER THIS APPLICATION FOR ADDED WORK.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77222	15041-20001-10232	19119 W VICTORY BLVD BLDG 9	91335	3	180B121   530	2128031***	R3-1-RIO	South Valley	Reseda - West Van Nuys	Reseda		1331.00	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM			PC Approved	04/28/2015 12:00:00 AM	ADDRESS	34.18675	-118.54997	EXPEDITED PER APPLICANTS REQUESTPV2. APARTMENT BUILDING. ( TWO MIRRORED BUILIDING ONE ADDRESS) (1 OF 2) BUILDING 9 , SYSTEM SIZE: 1.75 KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77223	16041-30000-14624	2391 N ROSCOMARE ROAD 1-10	90077	5	153B145    35	4378018002	RD2-1VL	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	Apartment			04/26/2016 12:00:00 AM	04/26/2016 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.1187	-118.46392	Plan check for new fire alarm system in 10 units appartment. Total fire alarm devices: 80	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77224	12041-10003-08597	2160 E 7TH ST	90023	14	124-5A219 253	5171024006	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/12/2012 12:00:00 AM			PC Info Complete	10/12/2012 12:00:00 AM	ADDRESS	34.03423	-118.22602	((((((((((  addition of more lites to title 24  10-01-12 m.z )))))))))))))))))  USING EXISTING BRANCH CIRCUITS IN NINE COOLER STORAGE ROOMS,INSTALLING COOLER-RATED LUMINAIRES, OCCUPANCY SENSORS, AND SWITCHES .INSTALLING STRIP LIGHTS ABOVEFOR MAINTENANCE PURPOSES.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77225	17041-20002-42970	15724 W NORDHOFF ST	91343	12	195B141    13	2672008002	RA-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			PC Approved	06/08/2018 12:00:00 AM	ADDRESS	34.23541	-118.47521	06-01-2018 changes to an permitted set of plan. Changes include update feeder size to 2/0 from PV distribution panel to Main service panel only. Everything else shall remain the same. Plan check only.Fee $0 due to California Senate Bill 1222	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77226	10041-10000-25132	12424 W WILSHIRE BLVD 6th & 7th-floors	90025	11	126B145   570	4267035015	[Q]C2-1VL-CDO	West Los Angeles	West Los Angeles	West Los Angeles		2674.02	Electrical	Electrical	Commercial			12/17/2010 12:00:00 AM	12/21/2010 12:00:00 AM		Permit Finaled	03/09/2011 12:00:00 AM	ADDRESS	34.04135	-118.47058	Ti in the restroom & corridoors area of a highrise building. (6th & 7th floor)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77227	13041-10001-29529	4827 N OAK PARK AVE	91316	5	168B133   178	2289004010	R1-1	South Valley	Encino - Tarzana	Encino		1396.00	Electrical	Electrical	1 or 2 Family Dwelling			10/23/2013 12:00:00 AM			PC Approved	11/13/2013 12:00:00 AM	ADDRESS	34.15857	-118.50467	Expedited RSES plan check per applicant request. ((((PV1.  Install 11 kW DC roof-mounted solar array, interconnect with main service panel.  inverter: Fronius IG Plus V 10.0 . 44 modules: Trina Solar TSM-250PA05.18.))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77228	17041-10000-09256	17350 W SUNSET BLVD	90272	11	126B117   458	4415018***	C2-1VL, [Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2627.04	Electrical	Electrical	Apartment			03/22/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Issued	04/13/2017 12:00:00 AM	ADDRESS	34.04043	-118.55311	Plan check for power only for Medium Voltage replacement of (7) 4800V disconnecting means and 1 additional disconnecting means 4800V.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77229	15041-20000-21416	6220 N TOPANGA CANYON BLVD Suite 9030	91367	3	180B105    60	2146029013	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			07/07/2015 12:00:00 AM			Corrections Issued	07/07/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	Plan check for Title 24 only. As built kiosk within shopping center. Total indoor area: 207 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77230	10041-20000-17261	6240 N LANKERSHIM BLVD	91606	2	177B169   177	2335029901	R3-1, [Q]C2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.01	Electrical	Electrical	Public Safety Only			08/31/2010 12:00:00 AM	08/31/2010 12:00:00 AM		Permit Finaled	02/22/2011 12:00:00 AM	ADDRESS	34.18433	-118.38614	Plan check for new installation of fire alarm system	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77231	19041-20000-39389	20301 W FULLBRIGHT PL	91311	12	207B113    83	2707004014	RA-1	North Valley	Chatsworth - Porter Ranch	Chatsworth	YES	1131.02	Electrical	Electrical	1 or 2 Family Dwelling			09/30/2019 12:00:00 AM	09/30/2019 12:00:00 AM		Permit Finaled	10/24/2019 12:00:00 AM	ADDRESS	34.26477	-118.57572	PV1.  Install 10.54 kW DC / 9.5 kW AC roof mounted grid tied PV system.  (31) modules with microinverters.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77232	18041-10000-39959	5028 W PICO BLVD	90019	10	129B181  1013	5070018033	C4-1-O	Central	Wilshire	P.I.C.O.		2172.00	Electrical	Electrical	Commercial			10/18/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	02/27/2019 12:00:00 AM	ADDRESS	34.04764	-118.3469	REMOVE HID OUTDOOR FIXTURES AND REPLACE WITH NEW LED FIXTURES. T/24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77233	13041-20000-12287	4141 N LANKERSHIM BLVD	91602	2	165B177   998	2423029034	C2-1VL-CDO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1436.03	Electrical	Electrical	Commercial			05/10/2013 12:00:00 AM			PC Approved	05/10/2013 12:00:00 AM	ADDRESS	34.14519	-118.36295	RENOVATION OF EXISTING RESTAURANT SPACE. PLAN CHECK FOR T24 ENERGY ONLY. TOTAL AREA 1390 SQ FT. PERMIT TO BE ISSUED BY PC STAFF ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77234	18041-10000-19372	507 N GARDNER ST	90036	5	141B177  1105	5526026010	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	09/04/2018 12:00:00 AM	ADDRESS	34.08056	-118.35334	INSTALL  NEW PV SYSTEM REATED 10.4KW WITH 32 MODULES ON A SINGLE FAMILY HOME.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77235	14041-10000-18641	4205 N KESTER AVE	91403	4	165A147   121	2276025009	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	1 or 2 Family Dwelling			07/10/2014 12:00:00 AM	07/10/2014 12:00:00 AM		Permit Finaled	08/25/2014 12:00:00 AM	ADDRESS	34.14717	-118.45952	Install roof mounted solar PV system on existing residential building.  Total system size = 7.6 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77236	11041-20000-20245	14104 W FOOTHILL BLVD	91342	7	225B153   185	2504011155	C2-1	North Valley	Sylmar	Sylmar		1064.02	Electrical	Electrical	Commercial			09/22/2011 12:00:00 AM	11/18/2011 12:00:00 AM		Permit Finaled	05/09/2012 12:00:00 AM	ADDRESS	34.31556	-118.44118	Existing 7-11.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77237	18041-20000-11474	19528 W LOS ALIMOS ST	91326	12	207B117    48	2708006019	RA-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1131.02	Electrical	Electrical	1 or 2 Family Dwelling			03/29/2018 12:00:00 AM	03/29/2018 12:00:00 AM		Permit Finaled	08/15/2018 12:00:00 AM	ADDRESS	34.26753	-118.55873	pv1install roof mounted pv system sized 10kw interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77238	10041-10000-18826	2050 W JOHN S GIBSON BLVD CRANE #1	90731	15	024B201     7	7440016912	[Q]M3-1	Harbor	Port of Los Angeles	Northwest San Pedro, Wilmington	YES	2951.01	Electrical	Electrical	Commercial			09/23/2010 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Closed	11/05/2012 12:00:00 AM	ADDRESS	33.75959	-118.28627	INSTALL A NEW CRANE AT BIRTH #102.  IN TERMINAL WBCT.  (CRANE #1 of 4)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77239	14041-10000-13814	11150 W SANTA MONICA BLVD #1050	90025	5	129B153   892	4323027008	C2-1, M2-1, M2-1VL, M2-2D	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			05/23/2014 12:00:00 AM	08/01/2014 12:00:00 AM		Permit Finaled	09/30/2014 12:00:00 AM	ADDRESS	34.04704	-118.44563	permit to be pulled at EPC counter only. Plan check for energy only. BLDG#14016-20-09379: TENANT IMPROVEMENT ON 10TH FLOOR (2,585.0 S.F.): DEMOLISH AND CONSTRUCT INTERIOR NON-BEARING PARTITIONS & DOORS; NEW DEMISING WALL TO SEPARATE TENANT SPACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77240	17041-20001-11364	12011 W VICTORY BLVD	91606	2	180B165   699	2322007055	C2-1L	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1239.01	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM			PC Approved	10/25/2017 12:00:00 AM	ADDRESS	34.18684	-118.39489	"10.25.2017 - Plan check for changes to approved set. Reducing conduit sizes from 1.5"" to 1"", changing conduit to EMT and removing the EGCs within. Reducing main feeder breakers for panels 201, 203, 206, 207, and HP from 100A to 80A, reducing corresponding feeders to #4AWG CU. Changes clouded.========PLANCHECK FOR POWER ONLY. NEW SERVICE UPGRADE TO 800 AMPS AND TENANT METERS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77241	15041-20000-26314	6633 W HOLLYWOOD BLVD	90028	13	148-5A185 113	5547004006	C4-2D-SN	Central	Hollywood	Hollywood Hills West		1902.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/28/2015 12:00:00 AM		Permit Finaled	05/17/2016 12:00:00 AM	ADDRESS	34.10174	-118.33447	Plan check for Title 24 only. Project site is an existing commercial building (restaurant). Project scope is a tenant improvement. Total lighting area = 6,207 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77242	10041-10000-23062	440 S VERMONT AVE # 103	90020	4	135B197   679	5077003020	C2-1	Central	Wilshire	Rampart Village	YES	2111.20	Electrical	Electrical	Commercial			11/17/2010 12:00:00 AM	11/17/2010 12:00:00 AM		Permit Finaled	02/23/2011 12:00:00 AM	ADDRESS	34.0659	-118.29143	FISET TIME TENANT IN COMMERCIAL SPACE	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77243	14041-10001-09885	626 W WILSHIRE BLVD 1F	90017	14	129A209    83	5144006025	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/08/2014 12:00:00 AM			PC Approved	10/08/2014 12:00:00 AM	ADDRESS	34.04843	-118.25695	This supplemental fee is for additional hours to application #   14041-10000-09885. collection of fees.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77244	16041-20000-20064	515 S FIGUEROA ST #100	90071	14	130-5A209  85	5151021011	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/08/2016 12:00:00 AM	11/16/2016 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	34.05199	-118.25764	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT ON  GROUND FLOOR ON PLAZA LEVEL SUITE 100 . MANUFACTURERS BANK. 3513 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77245	15041-10000-32152	111 S LUCAS AVE	90026	13	133-5A209  73	5153030024	CW	Central	Westlake	Westlake North	YES	2083.02	Electrical	Electrical	Apartment			09/29/2015 12:00:00 AM	03/29/2017 12:00:00 AM		Permit Finaled	07/30/2018 12:00:00 AM	ADDRESS	34.06147	-118.25986	NEW 4000 AMP SERVICE 125 UNIT APRTMENT BUILDING. PLAN CHECK FOR POWER AND ENERGY.METHANE ZONE.TITLE 24 SQUAREFOOTAGE ESTIMATED BY APPLICANT AT 97000 SQFT.  APPLICANT TO SUBMIT T24 AT A LATER TIME TODAY.  PLAN CHECKER TO VERIFY SQUAREFOOTAGE AND ADJUST FEES ACCORDINGLY.NEW CONSTRUCTION OF A 6-STORY BUILDING WITH 1-LEVEL SUBTERRANEAN LEVEL, 125-UNIT AFFORDABLE APARTMENT BUILDING, AUTOMATIC SPRINKLER SYSTEM (NFPA 13). BUILDING A (ABOVE PODIUM DECK) CONSIST OF TYPE III-A CONSTRUCTION, GROUP R-2, A-3 OCCUPANCIES. BUILDING B (ABOVE PODIUM DECK) CONSISTS OF TYPE V-A CONSTRUCTION. GROUP R-2, A-3 OCCUPANCIES. BASEMENT AND FLOORS 1 AND 2 (AT BUILDING B) CONSIST OF TYPE I-A CONSTRUCTION. GROUP R-2, B, A-3, S-2 OCCUPANCIES. (TYPE VA CONSTRUCTION OVER MODIFIED TYPE IA CONSTRUCTION.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77246	11041-10000-16480	3401 S WESTERN AVE	90018	8	120B193   729	5041005036	[Q]C2-1VL-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2220.02	Electrical	Electrical	Commercial			08/05/2011 12:00:00 AM			PC Approved	08/05/2011 12:00:00 AM	ADDRESS	34.02519	-118.30904	T.I. Existing car wash.  Adiing additional outdoor light fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77247	17041-10000-09296	13889 S FIGUEROA ST	90061	15	078B201   121	6132005017	M2-1VL-O	Harbor	Harbor Gateway	Harbor Gateway North		2911.30	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	ADDRESS	33.90637	-118.28299	PC for energy only, outdoor Title-24. Removing HID fixtures and replacing them with new LED ones. Area: 66,800.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77248	18041-30000-14362	1548 S CARMELINA AVE	90025	11	123B145    18	4267030011	R2-1	West Los Angeles	West Los Angeles	West Los Angeles		2675.02	Electrical	Electrical	1 or 2 Family Dwelling			04/19/2018 12:00:00 AM	04/19/2018 12:00:00 AM		Permit Finaled	05/21/2018 12:00:00 AM	ADDRESS	34.0371	-118.46406	Plan check for a PV1 roof-mounted PV system. System size is 4.5 kWac and consists of (18) modules, (18) micro-inverters, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77249	12041-10000-14298	621 S WESTERN AVE # 208-B	90005	10	135B193   955	5503031004	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2117.02	Electrical	Electrical	Commercial			06/20/2012 12:00:00 AM	08/03/2012 12:00:00 AM		Permit Finaled	10/25/2012 12:00:00 AM	ADDRESS	34.0628	-118.30928	TENANT IMPROVEMENT FOR RESTAURANT (1,769 SQFT), NON-BEARING INTERIOR PARTITION WALL, T-BAR CEILING ON 2ND FLOOR OF (E) SHELL BUILDING.FULL PLAN CHK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77250	15041-20000-34151	20023 W WELBY WAY	91306	3	180B113    68	2134012002	R1-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	11/12/2015 12:00:00 AM	ADDRESS	34.19301	-118.56953	PV1, roof mtd system6.89 kW system. (26) moduels: #KU2656ZPA, (1) Inverter PVI-6000-OUTD-US-Z-A. Simplified std. plan provided,	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77251	15041-10000-07415	1200 S CLUB VIEW DR 6TH FLR-6 NORTH	90024	5	135B157   112	4327024***	[Q]R5-3	West Los Angeles	Westwood	Westwood		2657.00	Electrical	Electrical	Commercial			03/13/2015 12:00:00 AM	03/17/2015 12:00:00 AM		Issued	03/17/2015 12:00:00 AM	ADDRESS	34.06748	-118.42481	5EA NEW LUMINAIRES IN EXISTING CORRIDOR OF A  HIGH RISE BUILDING. PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77252	15041-10000-37538	11933 N RICASOLI WAY	91326	12	216B109    55	2701078001	RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/06/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	02/03/2016 12:00:00 AM	ADDRESS	34.2897	-118.58501	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 5KW INTERCONNECTED WITH MSP.(20) SUNPOWER SPR-X20-250 MODULES(1) SUNNYBOY SB5000 INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77253	12041-10000-30825	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			12/21/2012 12:00:00 AM	03/13/2013 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.17126	-118.58861	T.I. to existing medical building #2 on partial of third floor (Kaiser Permanente).  Altering lighting and medical equipment.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77254	17041-10000-42471	531 N SIERRA BONITA AVE	90036	5	141B177   992	5526027005	R1-1-O	Central	Hollywood	Mid City West		1920.02	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2017 12:00:00 AM	12/19/2017 12:00:00 AM		Permit Finaled	12/26/2017 12:00:00 AM	ADDRESS	34.08116	-118.35439	NEW ROOFTOP SOLAR SYSTEM CONSIST OF 33 MODULES (LG LG360N2W-G4) AND 33 MICROINVERTERS (ENPHASE IQ6-60-X-US).  SYSTEM SIZE IS 11.88KWdc and 7.92KWac	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77255	16041-10000-40662	14445 W MAGNOLIA BLVD	91423	4	171A151     8	2248013011	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			11/17/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	12/20/2016 12:00:00 AM	ADDRESS	34.16501	-118.44805	PC for energy only. Remove HiD fixtures and replace with new LED fixtures. Total sqft = 22300.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77256	14041-20001-24801	7000 S HOOVER ST Unit #6	90044	8	102B201   641	6013023042	R3-1	South Los Angeles	South Los Angeles			2376.00	Electrical	Electrical	Commercial			09/10/2014 12:00:00 AM			PC Approved	11/06/2014 12:00:00 AM	ADDRESS	33.97589	-118.28691	expedite feesNew roof mounted PV system with Enphase Microinverter, Model M250-60-2LL for Unit #6.  System size 1.3KW.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77257	19041-20000-42595	11237 N NORRIS AVE	91331	7	210B157   154	2534003012	R1-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	1 or 2 Family Dwelling			10/18/2019 12:00:00 AM	10/22/2019 12:00:00 AM		Permit Finaled	01/22/2020 12:00:00 AM	ADDRESS	34.27428	-118.42063	PV1. INSTALL 3.60 KW DC SYSTEM WITH (10) MODULES/OPTIMIZERS AND (1) INVERTER(SE3000H) ON EXISTING PV SYSTEM.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77258	17041-10000-07235	10020 N REMMET AVE	91311	12	204B105   821	2747010***	MR1-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.13	Electrical	Electrical	Commercial			03/07/2017 12:00:00 AM	03/07/2017 12:00:00 AM		Permit Finaled	05/19/2017 12:00:00 AM	ADDRESS	34.25252	-118.60035	PC FOR ENERGY. REPLACE EXISTING HID LIGHT FIXTURES WITH NEW LED FIXTURES FOR INDOOR AND OUTDOOR USE. TOTAL AFFECTED AREA 21600 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77259	16041-10000-27751	16904 W CITRONIA ST	91343	12	201B133   482	2686026001	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2016 12:00:00 AM	09/02/2016 12:00:00 AM		Permit Finaled	09/26/2016 12:00:00 AM	ADDRESS	34.24611	-118.50054	PV1 ROOF TOP MOUNTED SOLAR SYSTEM 11.4KVA SOLAR EDGE INVERTER(SE11400A-US240) WITH 38 MODULES\ AND SOLAR EDGE POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77260	12041-20000-00334	4519 W COCKERHAM DR	90027	4	153B197   173	5588023037	RE11-1	Central	Hollywood	Greater Griffith Park	YES	1892.02	Electrical	Electrical	1 or 2 Family Dwelling			01/05/2012 12:00:00 AM	06/05/2012 12:00:00 AM		Permit Finaled	10/29/2014 12:00:00 AM	ADDRESS	34.11466	-118.29075	Ground and trellis mount PV system for single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77261	17041-10001-16480	1222 S ALVIRA ST	90035	5	132B173  1250	5087015005	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2017 12:00:00 AM			PC Approved	05/30/2017 12:00:00 AM	ADDRESS	34.05402	-118.37245	05/30/2017 Changes to an approved set of plans, Changes include the revision of the Main Service Panel from (E)125A to (E) 225A.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77262	15041-10000-01202	12103-12105 W SATICOY ST	91605	2	186B165   197	2307013013	(Q)C2-1VL, C2-1VL	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1210.20	Electrical	Electrical	Commercial			01/14/2015 12:00:00 AM	02/17/2015 12:00:00 AM		Permit Finaled	06/17/2015 12:00:00 AM	PIN	34.20884872	-118.39714573	TI to (E) bakery, expanding to occupy adjacent (E) ice cream parlor tenant space.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77263	13041-10000-01213	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			01/16/2013 12:00:00 AM	02/19/2013 12:00:00 AM		Permit Finaled	03/29/2013 12:00:00 AM	ADDRESS	34.07196	-118.24719	AT THE DODGER'S STADIUM, REMODELING LIGHTING SYSTEMS ON THE CONCOURSES ON LEVELS 4,7,AND 9-NEW PANELBOARDS AND CIRCUITS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77264	18041-20000-42333	2304 N MORENO DR	90039	4	148-5A205 117	5432019022	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Silver Lake	YES	1951.00	Electrical	Electrical	1 or 2 Family Dwelling			11/05/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	12/03/2018 12:00:00 AM	ADDRESS	34.10245	-118.26831	Plan check for PV roof mounted system, system size: 10.23kW DC, 9.4kW AC with 31 PV Modules and 31 microinverters connected to msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77265	12041-20000-01858	4775 N TOPEKA DR	91356	3	168B121   255	2176031031	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.01	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2012 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	03/29/2012 12:00:00 AM	ADDRESS	34.1569	-118.54918	pv system single family 9.0 kw	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77266	17041-20002-45534	13571 W VAUGHN ST	91340	7	213B157   824	2523003003	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			06/28/2018 12:00:00 AM			PC Approved	06/28/2018 12:00:00 AM	ADDRESS	34.27758	-118.42846	Revisions to approved set.  Approval for clouded portions of plan only.  Wiring detail changes.(((PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 2217.53 KW.  PV system is a feed and tariff system. RESUBMITTAL TO EXPIRED PLANS 15041-20000-08646(5614)  LG395 395 WATT MODULES(30) SMA 24(23) SMA 23(18) SMA 1857BUILDING PERMIT # 15016-20000-20234)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77267	11041-10000-11930	4910 N VAN NUYS BLVD	91403	2	169-5A151  69	2248007140	C1.5-1VL	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			06/09/2011 12:00:00 AM	07/05/2011 12:00:00 AM		Permit Finaled	08/04/2011 12:00:00 AM	ADDRESS	34.15985	-118.4485	TI IN AN EXISTING MEDICAL BUILDING. INSTALL A NEW UPS, PANELS AND CIRCUITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77268	14041-10000-14933	4821 N LANKERSHIM BLVD	91601	2	168B173   395	2353025048	C4-1-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			06/05/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	08/04/2014 12:00:00 AM	ADDRESS	34.15818	-118.37082	PLANCHECK FOR T24 ENERGY. TEANANT IMPROVEMENT. RITAS ICE CUSTARD.  896 SQFT, EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77269	17041-20001-35995	3127 S CORINTH AVE	90066	11	120B157   631	4250022020	R1V2	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			10/06/2017 12:00:00 AM			PC Approved	10/23/2017 12:00:00 AM	ADDRESS	34.02416	-118.43129	expeditepv1install roof mounted pv system sized 11.4kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77270	17041-20001-38501	20951 W BURTON ST	91304	3	192B109   822	2109004013	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			10/25/2017 12:00:00 AM			PC Approved	12/05/2017 12:00:00 AM	ADDRESS	34.2189	-118.59038	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 14.5 kWac and consists of (42) AC PV modules and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77271	11041-10000-00247	10201 W PICO BLVD #101-3rd FL	90035	5	129B161  1442	4315019013	[Q]CCS-O	West Los Angeles	West Los Angeles	Westside		2679.00	Electrical	Electrical	Commercial			01/06/2011 12:00:00 AM	02/16/2011 12:00:00 AM		Permit Finaled	05/17/2011 12:00:00 AM	PIN	34.05182951	-118.41257696	Ti in an existing commercial building. EPC is for T24 & Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77272	15041-20001-06074	7900 N NELSON ROAD	91402	6	189B153   966	2212028036	R1-1, [Q]M2-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1203.00	Electrical	Electrical	Commercial			09/23/2015 12:00:00 AM			PC Approved	09/23/2015 12:00:00 AM	ADDRESS	34.21499	-118.4422	9/23/2015 - Recheck for lost set.  Permit to be pulled under this supplemental application # (20001).  Lighting is exempt from CEC 130.2(C)3 because it is listed as an industrial site.Plan check for T-24 outside light for Rexford Industrial, LLC. Total area: 2297 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77273	18041-20000-41192	12881 N BRADLEY AVE	91342	7	222B149   636	2506003025	M2-1	North Valley	Sylmar	Sylmar		1065.20	Electrical	Electrical	Commercial			10/26/2018 12:00:00 AM	11/05/2018 12:00:00 AM		Permit Finaled	04/29/2019 12:00:00 AM	ADDRESS	34.30363	-118.45814	Power and lighting for test kitchen.  Plan check for Title 24 Part 6.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77274	17041-20000-24780	15530 W LANARK ST	91406	6	189B145    63	2654040003	M2-1	South Valley	Reseda - West Van Nuys	North Hills East		1275.20	Electrical	Electrical	Commercial			07/21/2017 12:00:00 AM	07/25/2017 12:00:00 AM		Issued	07/25/2017 12:00:00 AM	ADDRESS	34.2184	-118.47102	new fire alarm system 9 devices plus facp.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77275	15041-10000-11320	8926 N SUNLAND BLVD	91352	7	195B177   317	2404008035	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Foothill Trails District		1021.07	Electrical	Electrical	Commercial			04/16/2015 12:00:00 AM	04/16/2015 12:00:00 AM		Permit Finaled	08/07/2015 12:00:00 AM	ADDRESS	34.23146	-118.3665	New fire alarm system for a single story building, private school. Scope includes ( 1) fire alarm panel, (1) emergency voice control panel, (2) power supplies and (113) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77276	19041-10000-49743	3960 S GRAND VIEW BLVD 1-50	90066	11	111B157   368	4235026016	[T][Q]R4-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Apartment			12/06/2019 12:00:00 AM	06/05/2020 12:00:00 AM		Permit Finaled	06/02/2022 12:00:00 AM	ADDRESS	34.00193	-118.42873	FULL PC FOR A NEW 2000A SERVICE (120/208 3P,4W) SUPPLYING  50 SUBPANELS. THE 2000A SERVICE ALSO FEEDS FIVE HOUSE PANELS, AND OTHER LARGE  EQUIPMENT LOAD WITH A  TOTAL AFFECTED AREA OF 81,070 SQFT. BLD #19010-10000-00624	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77277	15041-20001-02664	12500 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM			PC Approved	01/31/2015 12:00:00 AM	ADDRESS	33.97857	-118.41114	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77278	11041-10000-01467	19750 S VERMONT AVE # 200	90502	15	057B197    44	7351033020	M3-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			01/25/2011 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	04/28/2011 12:00:00 AM	ADDRESS	33.85128	-118.29031	REMODEL OF OFFICES, CONFERENCE, AND RESTROOMSPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77279	18041-10001-28461	740 S BROADWAY	90014	14	127-5A209 107	5144015023	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			06/27/2019 12:00:00 AM			PC Approved	07/04/2019 12:00:00 AM	ADDRESS	34.04414	-118.25412	CHANGES TO AN APPROVED SET. CHANGES & ALTERATION TO ECTRICAL ROOM AND BATHROOMS. SCOPE ALSO INCLUDES REMOVING LBP HOUSE PANEL AND DISTRIBUTING THE LOADS TO OTHER PANELS. ALL CHANGES ARE CLOUDED UNDER DELTA 6. Original scope: PC FOR POWER AND ENERGY FOR  HIGH-RISE RETROFIT ORDINANCE  (12 STORY) WITH GENERATOR.   SCOPE INCLUDES TWO NEW 1000A  277/480V 3 PH. SERVICES, ONE OF THE SERVICE IS SUPPLYING FIRE PUMP. NEW LIGHTING EQUIPMENT AND CIRUCITS, NEW 100HP FIRE PUMP, ETC. TOTAL AFFECTED AREA  66000 SQ.F.  CINEMA SWITCHGEAR EXISTING TO REMAIN RE-FED FROM THE NEW 1000 AMP SERVICE.  ((B#18016-10000-06163))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77280	17041-10000-18987	2222 N MARAVILLA DR	90068	4	150B181   103	5549013025	RE9-1	South Valley	Hollywood	Hollywood Hills West	YES	1897.02	Electrical	Electrical	1 or 2 Family Dwelling			06/06/2017 12:00:00 AM	07/17/2017 12:00:00 AM		Permit Expired	09/13/2022 12:00:00 AM	ADDRESS	34.11034	-118.34337	Permit fee is $0.00 due to the Senate Bill 1222.ROOF MOUNTEDPV SYSTEM WITH (2)  ENERGY STORAGE SYSTEM. NEW PV SYSTEM RATED 6.6KW AC USING 21 MODULES. ENERGY STORAGE  SYSTEM  IS 5KW  EACH , TOTAL 10KW/(27KWH) FOR THE STORAGE.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77281	12041-10000-23582	12236 N BROOKMONT AVE	91342	7	219B145   707	2611040009	RA-1	North Valley	Sylmar	Sylmar	YES	1066.05	Electrical	Electrical	1 or 2 Family Dwelling			10/03/2012 12:00:00 AM	01/16/2013 12:00:00 AM		Permit Finaled	02/07/2013 12:00:00 AM	ADDRESS	34.29353	-118.46403	FOR A SFD, ROOF-MOUNTED 3.43 KW PHOTOVOLTAIC SYSTEM USING MICROINVERTERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77282	15041-10000-04083	10630 N SEPULVEDA BLVD	91345	7	207B145   393	2649011021	[Q]CR-1VL	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			02/11/2015 12:00:00 AM	04/02/2015 12:00:00 AM		Permit Finaled	09/04/2015 12:00:00 AM	ADDRESS	34.26357	-118.46694	CHANGE OF USE FROM DAY CARE TO MEDICAL OFFICE; ADDED LOAD IS LESS THAN 400A; NEW LOAD IS NEW CIRCUITS FOR LIGHTING AND POWER	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77283	17041-10000-33768	5135 W MARATHON ST	90038	13	141B193   319	5535012018	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	Apartment			09/20/2017 12:00:00 AM			Corrections Issued	09/20/2017 12:00:00 AM	ADDRESS	34.085	-118.31025	PC FOR 600A MEETER BANK REPLACEMENT. INSTALLING NEW MAIN DISCONNECT AND METER BANK TO REFEED ALL EXISTING SUBPANELS. EXISTING SERVICE RISER TO REMAIN IN PLACE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77284	12041-20000-14514	4500 N GABLE DR	91316	5	165B125    24	2184016007	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/21/2012 12:00:00 AM	07/10/2012 12:00:00 AM		Permit Finaled	07/20/2012 12:00:00 AM	ADDRESS	34.15215	-118.5283	Roof mounted photovoltaic system. Original application was for micro inverters, now changed to string inverter.  Fees charged only for additional plan check reveiw.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77285	16041-20001-30272	18903 W RINGLING ST	91356	3	171B121   498	2176010009	RA-1	South Valley	Encino - Tarzana	Tarzana		1398.01	Electrical	Electrical	1 or 2 Family Dwelling			08/25/2016 12:00:00 AM			PC Approved	09/21/2016 12:00:00 AM	PIN	34.16229368	-118.54458786	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10 kWac and consists of (1) inverter, (35) modules, and (1) combiner box. Standard plan is not being used.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77286	15041-20000-05058	5210 N LANKERSHIM BLVD	91601	2	171B173  1384	2350018081	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			02/20/2015 12:00:00 AM	07/22/2015 12:00:00 AM		Permit Finaled	06/07/2016 12:00:00 AM	ADDRESS	34.16634	-118.37406	NEW THEATER BUILDING WITH NEW 1000 AMP SERVICE.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77287	17041-10000-34459	11111 W SANTA MONICA BLVD Ste 1100	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			09/26/2017 12:00:00 AM			PC Info Complete	10/05/2017 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC for T24 only for TI. Total area of 1880sqft. Installing new circuits and relocating some lights.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77288	15041-10000-14937	2625 S KENWOOD AVE	90007	8	123B197  1036	5054005005	R2-1-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2222.00	Electrical	Electrical	1 or 2 Family Dwelling			05/15/2015 12:00:00 AM	06/01/2015 12:00:00 AM		Permit Finaled	06/18/2015 12:00:00 AM	ADDRESS	34.03195	-118.29932	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8 KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77289	19041-10000-51117	1991 W BLAKE AVE	90039	13	148-5A213 208	5442017021	[Q]CM-1XL-RIO	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	Commercial			12/11/2019 12:00:00 AM	05/22/2020 12:00:00 AM		Permit Finaled	03/06/2023 12:00:00 AM	ADDRESS	34.10086	-118.244	Full plan check for a new space located in an existing building. Scope includes 600-Amp service, new equipment and lighting with a total lighing area of 4780-SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77290	19041-20000-19126	3640-3660 W LOS FELIZ BLVD ev2	90027	4	153A205     2	5434015001	RD1.5-1XL	Central	Hollywood	Los Feliz	YES	1882.01	Electrical	Electrical	Apartment			05/21/2019 12:00:00 AM	12/04/2019 12:00:00 AM		Issued	12/04/2019 12:00:00 AM	ADDRESS	34.11585	-118.27241	ev2install 17 EV charging stations to an existing apartment building.  plan check for power.energy management system installed.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77291	11041-10000-02350	928 S WESTERN AVE # 215	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.00	Electrical	Electrical	Commercial			02/07/2011 12:00:00 AM	02/17/2011 12:00:00 AM		Permit Finaled	03/17/2011 12:00:00 AM	ADDRESS	34.05485	-118.30886	remodeling of existing retail store VENDOMEPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77292	19041-10000-14506	2177 N PONET DR	90068	4	151-5A193 131	5587026038	RE11-1D	Central	Hollywood	Hollywood United	YES	1893.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2019 12:00:00 AM	05/07/2019 12:00:00 AM		Issued	05/07/2019 12:00:00 AM	ADDRESS	34.11026	-118.30969	*Zero dollar permit fee per AB-1414/SB-1222*[E-PLAN]PLAN CHECK FOR ROOF MOUNTED 11.4KVA-AC PV SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SE11400H-US) WITH 49 MUDULES USING P400 OPTIMIZERS @15.925 KW DC	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77293	13041-20000-25692	19765 W RINALDI PL #100,200	91326	12	210B117   408	2701040041	C2-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.01	Electrical	Electrical	Commercial			09/17/2013 12:00:00 AM			PC Approved	09/17/2013 12:00:00 AM	PIN	34.27524406	-118.56474153	RETAIL ENERGY PLAN CHECK	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77294	14041-10000-35601	9934 N CANOGA AVE	91311	12	201B105    39	2747008026	CM-1, P-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.21	Electrical	Electrical	Commercial			12/24/2014 12:00:00 AM	12/24/2014 12:00:00 AM		Permit Finaled	01/08/2015 12:00:00 AM	ADDRESS	34.25089	-118.59713	T24 ONLY.  REMOVE HID LIGHT FIXTURES AND REPLACE WITH NEW LED FIXTURES. TOTAL AREA 8448 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77295	13041-20001-23614	20224 W VIA MADRIGAL	91326	12	219B113   294	2701062009	RE11-1-H	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			08/29/2013 12:00:00 AM			Corrections Issued	09/18/2013 12:00:00 AM	ADDRESS	34.29646	-118.57349	Expedite Fees.         <<<<ROOF MOUNTED PV SOLAR 9.9 KW on a single family dwelling.  Plan check and permit are for PV System ONLY, NOT for Service Upgrade or De-rating of the Main Breaker>>>>.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77296	19041-20000-36639	345 S SAN PEDRO ST	90013	14	129A213   344	5148005021	C2-2D-O	Central	Central City	Downtown Los Angeles		2062.00	Electrical	Electrical	Commercial			09/15/2019 12:00:00 AM	12/24/2019 12:00:00 AM		Permit Finaled	09/17/2021 12:00:00 AM	ADDRESS	34.04609	-118.24315	POWER AND ENERGY PLAN CHECK FOR CHANGE TO ELECTRICAL DISTRIBUTION SYSTEM AND LOADS OF A EXISTING 3-STORY OFFICE BUILDING. T24 INCLUDED, TOTAL SQUARE FOOTAGE = 8463 SF	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77297	14041-20000-30569	5624 N WILLIS AVE	91411	4	174B149   776	2244018003	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	1 or 2 Family Dwelling			11/04/2014 12:00:00 AM	11/04/2014 12:00:00 AM		Permit Finaled	02/03/2015 12:00:00 AM	ADDRESS	34.17289	-118.45502	PV1 CENTRAL/STRING INVERTER STANDARD PLAN. SIZE 6KW.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77298	18041-20000-44866	18325 W SUPERIOR ST	91325	12	201B125   300	2764004010	RA-1	North Valley	Northridge	Northridge East		1152.01	Electrical	Electrical	1 or 2 Family Dwelling			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	01/29/2019 12:00:00 AM	ADDRESS	34.24651	-118.5329	Plan check for a PV1 roof-mounted PV system. System size is 10.37 kWdc/9.5 kWac-CEC and consists of (1) 7.6 kWac rated inverter and (34) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77299	14041-20001-34954	18555 W VENTURA BLVD	91356	3	174B125   543	2160007037	C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			04/23/2015 12:00:00 AM			PC Approved	04/23/2015 12:00:00 AM	ADDRESS	34.1697	-118.53779	PC FOR CHANGES TO APPROVED SET OF PLANS. CHANGE ONLY INCLUDE TYPE OF CONTROL FOR LIGHITNG FIXTURES. NOTE ADDED TO INDICATE 0-10V CONTROL FOR SOME FIXTURES AND OTHER CONTROL FOR OTHERS. CHANGES PER INSPECTOR REQUEST.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77300	16041-10000-43121	16815 W DEVONSHIRE ST	91344	12	204B137   255	2684007021	C1-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1114.00	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM	12/08/2016 12:00:00 AM		Permit Finaled	03/15/2017 12:00:00 AM	ADDRESS	34.25766	-118.49866	PC for energy only. Outdoor Title 24. Remove HID fixture and replace with new LED fixture. Total area:18,825	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77301	15041-20001-20845	6501 W OLYMPIC PL	90035	5	132B173   458	5087007009	R1-1-O-HPOZ	Central	Wilshire	P.I.C.O.		2168.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM			PC Approved	07/14/2015 12:00:00 AM	ADDRESS	34.05819	-118.37215	Expedite per applicant request[[[[[Plan check for PV roof mounted system. System size: 6.0kW with 24 modules and 1 inveter(6.0kW)]]]]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77302	16041-20000-38743	882 S CRENSHAW BLVD	90005	4	132B189   777	5092002037	R3-1	Central	Wilshire	Greater Wilshire		2127.01	Electrical	Electrical	Apartment			11/01/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	01/13/2017 12:00:00 AM	ADDRESS	34.0569	-118.32157	PV2.  Install 7.2 kW roof mounted grid-tied PV system.  (24) modules with (1) 6kW rated central inverter with power optimizers.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77303	18041-20000-36197	10469 N SAN FERNANDO ROAD	91331	7	207B161   433	2620028006	M2-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			09/21/2018 12:00:00 AM	11/19/2018 12:00:00 AM		Permit Closed	03/17/2021 12:00:00 AM	ADDRESS	34.26046	-118.41643	change service fom overhead to underground.  plan check for power only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77304	19041-20000-42123	15950 W CHATSWORTH ST	91344	12	207B141   408	2668002017	A2-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	Commercial			10/16/2019 12:00:00 AM	10/16/2019 12:00:00 AM		Permit Finaled	02/25/2020 12:00:00 AM	ADDRESS	34.26449	-118.48014	Plan check for new  fire alarm alarm system, new fire alarm device: 55 and 1 FACP	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77305	19041-10001-07388	5500 W 98TH ST	90045	11	093B173   581	4128022906	LAX	West Los Angeles	Los Angeles International Airport	Westchester/Playa del Rey		2774.00	Electrical	Electrical	Commercial			08/15/2019 12:00:00 AM			Corrections Issued	09/15/2019 12:00:00 AM	ADDRESS	33.94764	-118.37749	Two fuses on main feeders changed to 200amps and 400 amps per medium voltage standards section 430.3Medium voltage temp powwer for a 5-story parking located in LAX airport. Scope includes a 3-section 5KV suppying a 5KV, 2000KVA tranformer connecting to a 3000AMP 277/480V distribution panel.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77306	17041-20000-31658	5536 N SATSUMA AVE	91601	2	174B173  1089	2416014005	MR2-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.10	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	09/05/2017 12:00:00 AM		Issued	09/05/2017 12:00:00 AM	ADDRESS	34.17136	-118.36741	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from warehouse to commercial kitchens/tenant improvement. Total lighting area = 1,931 sq. ft.Note: Building application has been generated under 17016-20000-25686	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77307	10041-10000-05167	8616 S LA TIJERA BLVD	90045	11	096B169   586	4123004008	[Q]C2-1VL-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			03/22/2010 12:00:00 AM	03/22/2010 12:00:00 AM		Permit Finaled	09/23/2010 12:00:00 AM	ADDRESS	33.95933	-118.39173	TENANT INPROVEMENT IN OFFICES- PLAN CHK IS FROR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77308	18041-20001-37522	6600 N TOPANGA CANYON BLVD #1084-E	91303	3	180B101   822	2139004044	(WC)UPTOWN-SN-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1351.14	Electrical	Electrical	Commercial			06/25/2019 12:00:00 AM			PC Approved	06/26/2019 12:00:00 AM	ADDRESS	34.19008	-118.60565	Revisions to approved set.  Change of lighting system design.this is plan check only.(((Plan check for Title 24 Energy only in existing retail space T.I. Total area: 1805 sq ft. B#18016-20000-31853)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77309	15041-20001-06068	7247 N HAYVENHURST AVE Unit A5	91406	6	186B137   305	2226001906	[T][Q]M2-1VL	South Valley	Reseda - West Van Nuys	Lake Balboa		1321.02	Electrical	Electrical	Commercial			08/27/2015 12:00:00 AM			PC Approved	08/27/2015 12:00:00 AM	ADDRESS	34.20296	-118.49362	Changes to approved set.  Relocation of lighting circuits.  Changes to layout of switchgear including relocating loads to supply side of main circuit breaker.***** Previous Work Description *****     Plan check for power and Title 24 (energy).  Total area = 8,868 sq. ft.T.I. to existing commercial warehouse and office space.  New lights and panel upgrade for 3 200 A panels.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77310	16041-20000-06706	4151 W PROSPECT AVE BLDG G	90027	4	148-5A201 583	5591021014	[Q]M1-1D	Central	Hollywood	Los Feliz	YES	1952.02	Electrical	Electrical	Commercial			02/25/2016 12:00:00 AM	05/05/2016 12:00:00 AM		Permit Finaled	06/26/2017 12:00:00 AM	ADDRESS	34.10191	-118.28217	Refurbishing of busing and adding new circuit breakers to (E) switchgear.  Plan check for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77311	13041-20001-12826	14703 W GREENLEAF ST	91403	4	166-5A149 151	2276013002	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.04	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	34.14926	-118.45388	(((6/25/2013: DOWNSIZED WIRE FROM #8 TO #10. THIS IS A PLAN CHECK ONLY.)))PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 3.5 KW. USING ENPHASE MICROINVERTER. NONSTANDARD PLAN. TOTAL OF 14 MODULES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77312	14041-10000-13176	3315 W PICO BLVD	90019	10	129B189   986	5081022029	C4-1-O	Central	Wilshire	Olympic Park		2131.00	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM			PC Approved	05/16/2014 12:00:00 AM	ADDRESS	34.04732	-118.31624	"permit to be pulleed at EPC counter only. Plan check for energy only. Less than 400A and not hazardous per applicant.  BLGD#14016-20-04461: CHANGE OF USE: IRREGULAR 54' X 46'-9"" (2,200 SF) PORTION OF (E) RETAIL -TO- (N) BAKERY & RETAIL ON GROUND FLOOR OF (E) 2-STORY BLDG."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77313	19041-20000-52855	13713 W OXNARD ST	91401	2	177B157   801	2239023014	(T)[Q]RAS4-1VL	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.01	Electrical	Electrical	Apartment			12/20/2019 12:00:00 AM	03/11/2021 12:00:00 AM		Permit Finaled	09/12/2022 12:00:00 AM	ADDRESS	34.17963	-118.43183	Install new 800 amp 120/240 3phase 4 wire service. Provide new panels, equipments and lighting. Total area: 12449 sq ft. B#18010-20000-06115	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77314	19041-10000-47578	4785 E VALLEY BLVD	90032	14	135A233    82	5215028035	[Q]C2-1VL	East Los Angeles	Northeast Los Angeles	LA-32		2014.02	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Issued	11/19/2019 12:00:00 AM	ADDRESS	34.06525	-118.18082	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES-T/24 ONLYOUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77315	13041-10000-10159	12121 W WILSHIRE BLVD	90049	11	126B145   192	4264026055	[Q]C4-1VL-CDO	West Los Angeles	Brentwood - Pacific Palisades			2643.02	Electrical	Electrical	Commercial			04/19/2013 12:00:00 AM			PC Approved	04/19/2013 12:00:00 AM	PIN	34.04391963	-118.46825257	T24 ENERGY PLAN CHECK FOR HAIR SALON NON HIGHRISE. 4075 SQRFT. ELECTRICAL PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77316	19041-20000-52279	8218 W 3RD ST	90048	5	138B173   923	5511030023	C2-1VL-O	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	Commercial			12/18/2019 12:00:00 AM	03/06/2020 12:00:00 AM		Issued	03/06/2020 12:00:00 AM	ADDRESS	34.07236	-118.36861	Plan check for Title 24 Energy only, new lighting lighting in the area. Total area: 1110 sq ft. B#19016-20000-38936	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77317	11041-10000-08145	421 N HENRY FORD AVE	90744	15	027B213     1	7440003***	M3, M3-1VL	Harbor	Wilmington - Harbor City	Wilmington		2947.00	Electrical	Electrical	Commercial			04/22/2011 12:00:00 AM	06/21/2011 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	33.77533	-118.24134	Installing 6 new feeders, X-formers, VFD & pumps for an oil wells. EPC is for power.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77318	19041-10000-27490	15203 W OXNARD ST	91411	6	177B145   431	2242026004	M3-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Commercial			07/17/2019 12:00:00 AM	07/18/2019 12:00:00 AM		Permit Finaled	08/13/2019 12:00:00 AM	ADDRESS	34.17957	-118.46426	remove HID fixtures and replace with new LED fixtures (Outdoor only)- T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77319	13041-10000-30656	1880 N ACADEMY DR COMBAT-RANGE	90012	1	141B213    22	5415004900	[Q]OS-1XL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	9800.10	Electrical	Electrical	Commercial			11/01/2013 12:00:00 AM	08/21/2014 12:00:00 AM		Permit Finaled	09/12/2016 12:00:00 AM	ADDRESS	34.08269	-118.24139	Building 3 of 5:  COMBAT RANGE. INSTALLING NEW ELECTRICAL PANELS, NEW CONVENIENCE RECEPTABLES. TOTAL AREA OF ILLUMINATION IS 7782 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77320	10041-10000-22227	2242 S FEDERAL AVE	90064	11	123B153   325	4260015020	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			11/05/2010 12:00:00 AM	11/08/2010 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	ADDRESS	34.03439	-118.44489	Tenant improvement in an animal clinicplan chk is for tite 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77321	18041-20000-46682	620 N SIENA WAY	90077	5	141B149   172	4362002003	RE40-1-H-HCR	West Los Angeles	Bel Air - Beverly Crest	Bel Air-Beverly Crest	YES	2621.00	Electrical	Electrical	1 or 2 Family Dwelling			12/10/2018 12:00:00 AM	12/10/2018 12:00:00 AM		Permit Finaled	01/02/2020 12:00:00 AM	ADDRESS	34.0822	-118.44643	Plan check for power only. Poject site is a single family dwelling. Project scope is the installation of an 150 kW optional standby generator.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77322	16041-10000-23568	11405 W CHANDLER BLVD	91601	2	171B173   101	2350011016	C4-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1252.00	Electrical	Electrical	Apartment			07/06/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	34.1682	-118.37935	Plan Check only. Change of engineerPemit is under application # 15041-10000-22320(((NEW 7-STORY MIXED-USE BUILDING (5-STORY TYPE V APARTMENT OVER 2-STORY TYPE I PARKING GARAGE AND RETAIL ON GROUND FLOOR). APARTMENT WITH 82 RESIDENTIAL UNITS.  PLAN CHECK FOR POWER AND ENERGY.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77323	13041-20000-32592	5123 W VERONICA ST	90008	10	117B177   601	5029002049	R1-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Empowerment Congress West Area		2360.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2013 12:00:00 AM	11/21/2013 12:00:00 AM		Permit Finaled	12/23/2013 12:00:00 AM	ADDRESS	34.01308	-118.35672	PC FOR PV1 SINGLE FAMILY DWELLING. 26 MODULES. TRANSFORMERLESS INVERTER. NONSTANDARD PLAN.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77324	14041-20000-29240	12946 W HESBY ST	91423	4	171B161   914	2358028008	R1-1	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1247.00	Electrical	Electrical	1 or 2 Family Dwelling			10/22/2014 12:00:00 AM	11/10/2014 12:00:00 AM		Permit Finaled	11/20/2014 12:00:00 AM	ADDRESS	34.16214	-118.41579	PV1. ROOFMOUNTED SOLAR SYSTEM. CENTRAL INVERTER. NON STANDARD PLAN. SYSTEM SIZE: 7KW DC.(21) SUNPOWER SPR MODULES, (1) SUNNYBOY6000Note: The solar PV installation shall comply with FPB rquirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77325	13041-10005-19659	1540 N VINE ST	90028	13	148-5A189 312	5546026035	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Apartment			01/12/2016 12:00:00 AM	01/12/2016 12:00:00 AM		Permit Finaled	07/01/2016 12:00:00 AM	ADDRESS	34.09918	-118.32644	( 1-12-2016  CHANGES MADE TO PREVIOUSLY APPROVED SET DELTA 14    )                               (12-21-15: CHANGES MADE TO APPROVED SET. SHORT CIRCUIT CALCULATIONS PER INSPECTOR AND ADDED SERIES RATING COMBINATIONS WITH MOTOR LOAD CONTRIBUTIONS. PLAN CHECK ONLY))POWER AND ENERGY PLAN CHECK 287 UNIT APARTMENT BUILDING WITH FUTURE RETAIL SPACES. 7 STORY  LOW RISE BUILDING. VARIANCE TO SEPERATE FIRE ALARM HAS BEEN FILED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77326	15041-10000-13236	8361 N LAUREL CANYON BLVD	91352	6	192B165   367	2633006019	C2-1VL, P-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1210.10	Electrical	Electrical	Commercial			05/01/2015 12:00:00 AM	05/21/2015 12:00:00 AM		Permit Finaled	09/16/2015 12:00:00 AM	ADDRESS	34.22301	-118.39669	Full plan check for a change of use from a retail to a dental office. Scope includes new lighting, equipment and receptacles in an area of 1399-SQ feet located in a single story building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77327	15041-20001-32084	135 S BEACHWOOD DR	90004	4	138B189  1014	5515023017	R1-1-HPOZ	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.0726	-118.32252	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof mounted solar array on a SFD. Interconnect with a 400A split bus panel (derating 200A main to 175A).System size: 7.2kW (3+4.2). (24) 327W pv modules.]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77328	14041-20001-13665	20816 W CAMPANIA LANE	91326	12	213B109   402	2701068013	RZ4-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM			PC Approved	06/05/2014 12:00:00 AM	ADDRESS	34.27972	-118.58661	Expedite per customer request.6.33KW PV1 roof-mounted system with (28) Yingli YL250P modules and a PVI-6000-OUTD-US transformerless inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77329	19041-10000-38807	6401 S AVALON BLVD	90003	9	105B205  1053	6006018001	C2-1VL-CPIO	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Un		2393.30	Electrical	Electrical	Apartment			09/26/2019 12:00:00 AM	01/30/2020 12:00:00 AM		Permit Finaled	08/06/2021 12:00:00 AM	ADDRESS	33.98137	-118.26542	FULL PLAN CHECK FOR A NEW  100%  AFFORDABLE HOUSING  SCOPE INCLUDES NEW 800A SERVICE SERVING A 600A RESIDENTIAL SWITCHBOARD AND 400 HOUSE SWITCHBOARD. FIRE VARIENCE SUBMITTED. PLANS EXPEDITED PER APPLICANT REQUESTB#19010-10000-04269	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77330	13041-20000-00174	12005 W ALBERS ST 1-24	91607	2	174B165   830	2348002041	R3-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	Apartment			01/03/2013 12:00:00 AM	03/01/2013 12:00:00 AM		Permit Finaled	02/27/2014 12:00:00 AM	ADDRESS	34.17044	-118.39439	New fire alarm system for a new apartment building.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77331	19041-10000-30868	948 E 2ND ST	90012	14	129A217   139	5163006012	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			08/07/2019 12:00:00 AM	08/08/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.047	-118.23338	Remove HID fixtures and replace with new LED fixtures (Outdoor Only) - T24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77332	18041-20000-44824	13360 W VAN NUYS BLVD	91331	7	207B157   581	2620006003	[Q]C2-1VL-O-CDO-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	Commercial			11/26/2018 12:00:00 AM	11/26/2018 12:00:00 AM		Permit Finaled	02/07/2019 12:00:00 AM	PIN	34.26430494	-118.42388685	PV3.  Install 9.735 kW AC-CEC roof mounted grid tied PV system.  (33) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77333	14041-10001-27483	7349 W 91ST ST	90045	11	093B157    38	4119017011	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2766.04	Electrical	Electrical	1 or 2 Family Dwelling			10/10/2014 12:00:00 AM			Reviewed by Supervisor	10/29/2014 12:00:00 AM	ADDRESS	33.95445	-118.42434	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST. <<PV1, INSTALL 6.885 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL. (27) MODULES: KYOCERA KD255GX-LFB3(1) INVERTER: SOLAREDGE # SE5000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77334	12041-20000-23127	20255 W CORISCO ST	91311	12	198B113   202	2748001049	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.03, 1134.21	Electrical	Electrical	Commercial			09/27/2012 12:00:00 AM	11/15/2012 12:00:00 AM		Permit Finaled	04/05/2013 12:00:00 AM	ADDRESS	34.23564	-118.5751	Plan check for energy and emergency lighting. New office space inside of a warehouse. 14500 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77335	17041-20000-38488	200 S LOS ANGELES ST Suite C	90012	14	130-5A213 175	5161024039	[Q]C2-4D-O-CDO	Central	Central City	Historic Cultural		2062.00	Electrical	Electrical	Commercial			10/25/2017 12:00:00 AM			Corrections Issued	10/25/2017 12:00:00 AM	ADDRESS	34.05007	-118.2433	Plan check for Title 24 only. Project site is an existing commercial tenant space in a mixed-use building. Project scope is a change of use from retail to gym/tenant improvement. Total lighting area = 2,769 sq. ft.Note: Building application has been generated under 17016-10000-31097	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77336	15041-20000-26118	4832 N TUJUNGA AVE	91601	2	168B173   228	2353023019	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.02	Electrical	Electrical	Commercial			08/12/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	10/21/2016 12:00:00 AM	ADDRESS	34.1586	-118.37883	Plan check for new 1600 amps  service upgrade to existing school	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77337	10041-10000-04834	1955 W SLAUSON AVE	90062	8	108B193  1312	5005018029	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2325.00	Electrical	Electrical	Commercial			03/17/2010 12:00:00 AM			PC Info Complete	05/18/2010 12:00:00 AM	PIN	33.98940747	-118.3127929	T.I. for existing building (Auto Parts).  Install general and emergency lighting.  Plan check for energy only.NOTE THAT FULL PLAN CHK MAY BE REQUIRED	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77338	14041-20001-33482	6320 N TOPANGA CANYON BLVD UNIT 1640	91367	3	180B105    79	2146029019	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			07/29/2015 12:00:00 AM			PC Approved	07/29/2015 12:00:00 AM	ADDRESS	34.18578	-118.60536	07/29/2015 Changes to an approved set of plans. Changes include the installation of bug-eyes, revised photometric analysis, and the removal of a 200-amp panel. All changes have been clouded.*****Previous Work Description*****New 1-story building for a restaurant.  Install subpanels, branch circuits, and lighting.  Plan check for power and energy. Part of westfield village project. this is TI. Il Fornario	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77339	14041-10000-12722	835 E 28TH ST	90011	9	118-5A209 193	5128019020	RD2-1	South Los Angeles	Southeast Los Angeles	South Central		2267.00	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	06/20/2014 12:00:00 AM	ADDRESS	34.01865	-118.2595	Install roof mounted solar arraysystem size = 3.825 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77340	12041-10004-16076	5310 W HOLLYWOOD BLVD	90027	13	148-5A195 118	5544020002	C2-1D	Central	Hollywood	East Hollywood		1905.20	Electrical	Electrical	Commercial			07/01/2015 12:00:00 AM			PC Approved	07/01/2015 12:00:00 AM	ADDRESS	34.10158	-118.3062	REVISED PLANS TO SHOW CHANGES MADE IN THE FIELD- DELTA F CHANGES- NEW PANELBOARD WITH 8EA NEW CIRCUITS; REVISIONS TO LIGHTING SYSTEMPLANS ARETHE AS-BUILT  SET.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77341	19041-10000-38685	7101 N FAIR AVE	91605	2	183B173   139	2319022004	M2-1	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1230.10	Electrical	Electrical	Commercial			09/25/2019 12:00:00 AM	09/26/2019 12:00:00 AM		Permit Finaled	11/15/2019 12:00:00 AM	ADDRESS	34.19948	-118.3751	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77342	19041-20001-42825	7820 W ELECTRA DR	90046	4	150B177   314	5569018062	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			11/07/2019 12:00:00 AM			PC Approved	11/19/2019 12:00:00 AM	ADDRESS	34.10588	-118.3631	Expedite feePV1.  Install 17.280 kW DC / 15.568 kW CEC-AC roof mounted grid tied PV system.  (48) modules with 11.4 kW rated inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77343	14041-20000-16743	15260 W VENTURA BLVD SUITE 825	91403	4	168B145   968	2276007037	C2-2	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			06/23/2014 12:00:00 AM	06/23/2014 12:00:00 AM		Permit Finaled	10/09/2014 12:00:00 AM	ADDRESS	34.15356	-118.4658	PC FOR TITLE-24 ENERGY AND EMERGENCY ONLY.  EXISTING HIGH RISE BUILDING FLOOR 825 WITH NEW LIGHTING FIXTURES ONLY.  ALL CIRCUITS EXISTING NO NEW LOADS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77344	17041-10000-01528	215 W 14TH ST	90015	14	124-5A207 114	5134025024	C2-2D-O	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			01/23/2017 12:00:00 AM	11/22/2019 12:00:00 AM		Issued	11/22/2019 12:00:00 AM	ADDRESS	34.03643	-118.26383	FULL PLAN CHECK FOR A NEW 7 STORY MIXED USE BUILDING WITH  6 STORY RESIDENTIAL ( TOTAL 154 UNITS) OVER 1 STORY RETAIL, OFFICE, PARKING, OVER 2 LEVELS SUBTERRANEAN PARKING. SCOPE  INCLUDES ONE  4000 AMP 480/277V SERVICE AND AND 4 MAIN DISTRIBUTION PANELS  WITH TOTAL AREA OF 160,000 SQ FT. T24 IS UNDER 2013 CODE.NOTE FOR COUNTER STAFF/PLAN CHECKER, PLEASE CHECK T24 DOCUMENT BEFORE TAKING IN THE PLAN.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77345	17041-20000-46498	5536 W SIERRA VISTA AVE 1-41	90038	13	144B193   946	5536020028	RD1.5-1XL	Central	Hollywood	Hollywood Studio District		1917.20	Electrical	Electrical	Apartment			12/28/2017 12:00:00 AM	01/11/2018 12:00:00 AM		Permit Finaled	08/07/2018 12:00:00 AM	ADDRESS	34.08942	-118.31265	0$ permit fees due to senate bill 1222pv2install roof mounted pv system sized 30kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77346	12041-20000-11142	1940 CENTURY PARK EAST STE 250	90067										Electrical	Electrical	Commercial			05/15/2012 12:00:00 AM			PC Approved	05/15/2012 12:00:00 AM				Ti for existing office space. Plan check for energy and emergency lighting. Low rise commercial building. 1591 conditioned sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77347	15041-20000-17256	5252 N CLEON AVE	91601	2	171B173   376	2416006010	R3-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2015 12:00:00 AM	06/10/2015 12:00:00 AM		Permit Expired	07/05/2017 12:00:00 AM	ADDRESS	34.16644	-118.36845	PV1. Standard plan. Install roof mounted solar system sized 3.6 KW. Interconnected with main service panel.(18) KU 260 Modules(1) PVI 3.6-TL Inverter	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77348	18041-10000-07314	821 E TRACTION AVE # 109-110	90013	14	127-5A215  72	5163015007	M3-1-RIO	Central	Central City North	Historic Cultural		2060.31	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	ADDRESS	34.04508	-118.23524	PC FOR T-24 FOR LIVE-WORK SPACES FOR ENERGY ONLY. FOR UNITS 109-110TOTAL AFFECTED 4336 SQ. FTTHIS IS PLAN CHECK ONLY PERMIT PULLED UNDER  17041-10000-32865B#16016-10001-27107	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77349	13041-20000-33349	5503 S FIGUEROA ST	90037	9	108B201   796	5001021032	C2-1VL	South Los Angeles	South Los Angeles	Voices of 90037		2327.00	Electrical	Electrical	Commercial			11/27/2013 12:00:00 AM			PC Approved	01/30/2014 12:00:00 AM	ADDRESS	33.99219	-118.28294	PC FOR T24 ENERGY ONLY. PER APPLICANT REQUEST. WORK DONE IN COMMUNITY AREA.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77350	11041-10000-12749	501 WORLDWAY parking	90042	11	090B169    34	4129028900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/22/2011 12:00:00 AM			Corrections Issued	10/23/2012 12:00:00 AM	PIN	33.94463112	-118.38247895	Replace elevators.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77351	11041-20000-23836	6039 N DE SOTO AVE	91367	3	177B105    63	2149005032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			11/07/2011 12:00:00 AM			PC Approved	11/07/2011 12:00:00 AM	ADDRESS	34.18005	-118.5908	Exterior lighting addition only ( delta 1 ).T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77352	11041-10000-22546	5701 S CENTRAL AVE	90011	9	108B209  1276	5103015049	M1-1	South Los Angeles	Southeast Los Angeles			2294.20	Electrical	Electrical	Commercial			10/21/2011 12:00:00 AM	04/19/2012 12:00:00 AM		Permit Finaled	10/01/2012 12:00:00 AM	ADDRESS	33.99059	-118.25665	New electrical for change of use from industrial to retail.  Plan check for power and T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77353	16041-10000-09016	1153 S SANTEE ST 3RD FLR	90015	14	124-5A209  66	5145021028	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/15/2016 12:00:00 AM			PC Info Complete	03/15/2016 12:00:00 AM	ADDRESS	34.03654	-118.25728	T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING ON THE 3RD FLOOR. SCOPE INCLUDES 1 NEW 30A PANEL,  NEW LIGHTS AND RECEPTACLES FOR OFFICE AND CORRIDOR SPACES. TOTAL AFFECTED AREA IS 1641 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77354	15041-20000-00231	16342 W ROYAL HILLS DR	91436	5	159B137   143	2293012020	RE15-1-H	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/06/2015 12:00:00 AM	01/06/2015 12:00:00 AM		Permit Finaled	05/06/2015 12:00:00 AM	ADDRESS	34.13493	-118.48894	PV1. Install roof mounted PV system sized 5.2 kW. Interconnected with main service pannel. (30) Q.PRO 230 Modules(1) Advanced Energy PVP 5200 inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77355	17041-10001-00360	300 W WORLD WAY #335, 336,-337  T3	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			05/05/2017 12:00:00 AM	05/17/2017 12:00:00 AM		Permit Finaled	06/22/2017 12:00:00 AM	PIN	33.94094587	-118.40577128	PC FOR CHANGES TO APPROVED SET OF PLANS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77356	15041-10000-22347	375 W 9TH ST	90731	15	015B201   393	7455009003	RD1.5-1XL	Harbor	San Pedro	Central San Pedro		2971.10	Electrical	Electrical	1 or 2 Family Dwelling			07/14/2015 12:00:00 AM	07/14/2015 12:00:00 AM		Permit Expired	08/08/2017 12:00:00 AM	ADDRESS	33.7359	-118.2852	Plan check for a PV1 roof-mounted PV system. System size is 3 kWac and consists of (1) inverter, and (15) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77357	11041-20000-02616	1120 N EL MEDIO AVE	90272	11	132B125    70	4420007002	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.02	Electrical	Electrical	1 or 2 Family Dwelling			02/09/2011 12:00:00 AM	05/03/2011 12:00:00 AM		Permit Finaled	05/26/2011 12:00:00 AM	ADDRESS	34.05427	-118.53151	PLAN CHECK FOR NEW 15.2KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM FOR SINGLE FAMILY DWELLING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77358	15041-10000-30854	11300 W OLYMPIC BLVD # 910	90064	11	126B153  1108	4260019022	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2677.00	Electrical	Electrical	Commercial			09/17/2015 12:00:00 AM			PC Approved	09/17/2015 12:00:00 AM	ADDRESS	34.03792	-118.44134	Energy plan check for an office T.I located in the 9th floor of  high rise building. Scope includes new lighting and receptacles; total 3350-SQ feet. Note, application is for plan check only, permit fee is paid under 15041-10000-29103.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77359	11041-10000-24941	735 S SOTO ST	90023	14	124-5A221 235	5183027003	C1-1	East Los Angeles	Boyle Heights	Boyle Heights		2046.00	Electrical	Electrical	Commercial			11/21/2011 12:00:00 AM	12/01/2011 12:00:00 AM		Permit Finaled	06/19/2012 12:00:00 AM	ADDRESS	34.03486	-118.21556	New fire alarm system for existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77360	17041-10000-37901	7001 S CENTRAL AVE	90001	9	102B209     1	6007020***	M3-1, MR2-1	South Los Angeles	Southeast Los Angeles	Community and Neighbors for Ninth District Unity		2393.30	Electrical	Electrical	Commercial			10/20/2017 12:00:00 AM	01/23/2018 12:00:00 AM		Permit Finaled	08/27/2018 12:00:00 AM	ADDRESS	33.97767	-118.25662	PC FOR INSTALLATION OF DISPENSING EQUIPMENT IN HAZARDOUS LOCATION FOR POWER AND ENERGY.  SCOPE INCLUDES POWER TO DISPENSERS AND CANOPY LIGHTS WITH ADDITIONAL EQUIPMENT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77361	17041-10001-24366	8211 N REMMET AVE	91304	3	189B105    35	2110019022	[Q]CM-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1343.05	Electrical	Electrical	Commercial			07/19/2017 12:00:00 AM			PC Approved	08/09/2017 12:00:00 AM	ADDRESS	34.21802	-118.60044	EXPEDITE FEESPC FOR COMMMERCIA PV SYSTEM USING 14KW INVERTER AND 32 MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77362	19041-10001-05044	1062 N SWARTHMORE AVE 2-101	90272	11	129B125   462	4423016***	[Q]R3-1	West Los Angeles	Brentwood - Pacific Palisades			2625.01	Electrical	Electrical	Commercial			04/01/2019 12:00:00 AM			PC Approved	04/01/2019 12:00:00 AM	ADDRESS	34.04804	-118.52468	CHANGES TO AN APPROVED SET  OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA 1. CHANGES INCLUDE ADDING EMERGENCY BUG-EYES, ADDING EXIT SIGNS, AND REVISING EMERGENCY PHOTOMETRICS.NOTE: PERMIT FEES ARE PAID UNDER PCIS#19041-10000-05044	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77363	11041-10000-25989	189 S THE GROVE DR STE C-10	90036	4	138B177  1132	5512003042	C1.5-2D-O	Central	Wilshire	Mid City West		2145.00	Electrical	Electrical	Commercial			12/08/2011 12:00:00 AM	03/07/2012 12:00:00 AM		Permit Finaled	08/02/2012 12:00:00 AM	ADDRESS	34.07125	-118.35662	RESTAURANT TENANT IMPROVEMENT WITHIN EXISTING LEASE SPACE; CHANGE OF USE; PROJECT INCLUDES AN EXTERIOR DINING PATIO  ( 3566 SF)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77364	17041-10001-03365	3939 S VERMONT AVE	90037	8	117B197   994	5037019059	C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Commercial			11/29/2017 12:00:00 AM			PC Approved	11/29/2017 12:00:00 AM	ADDRESS	34.01361	-118.2919	PLAN CHECK PER APPLICANT REQUEST TO REFLECT REVISIONS TO APPROVED SET MARKED UNDER DELTA 1.SCOPE INCLUDES REVISED POWER PLANS TO REFLECT WIRING FOR FUTURE  FA (FOR SIGNALING). THIS IS PLAN CHECK ONLY!Plan Check for power and energy for new 2 story High School Building. Service size: 1,200AB#17010-10000-00374	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77365	19041-10000-00078	3790 N MULTIVIEW DR	90068	4	159B177   279	2425009013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Hollywood Hills West	YES	1437.00	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM	02/05/2019 12:00:00 AM		Permit Finaled	03/22/2019 12:00:00 AM	ADDRESS	34.13314	-118.35814	Note: Fees are $0 due to Assembly Bill 1414.NEW ROOF MOUNTED SOLAR SYSTEM USING CENTRAL INVERTERS WITH ONE BATTERY BACKED UP SYSTEM(LG CHEM). TOTAL SYSTEM SIZE IS 15.120KWDC AND 12.6KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77366	16041-20000-31918	8588 N TELFAIR AVE	91352	6	192B169   163	2632015031	[Q]MR1-1VL-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1219.00	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	09/27/2016 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.22586	-118.38537	Plan check for power and energy. New 1-story Warehouse/Mfg building. 800A service. Core and shell. T24 Indoor area: 180sqft; Outdoor area: 9,141sqft.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77367	11041-10000-04911	1133-1141 S BOYLE AVE	90023	14	123A219    19	5170007015	MR2-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			03/15/2011 12:00:00 AM	04/05/2011 12:00:00 AM		Permit Finaled	11/01/2011 12:00:00 AM	ADDRESS	34.03014	-118.2206	FIRST TIME TENANT- COMBINING TWO TENANT SPACES TO FORM WAREHOUSE AND OFFICES WITH A MEZZANINE )))))))))))))Electrical installation for new commertial building.  New 1600A 480/277V 3ph 4W Serivce. EPCPower and Energy (T-24).  08041-10000-08756	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77368	12041-10000-05424	810 S SANTA FE AVE	90021	14	124-5A217 360	5166003002	M3-1	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			03/09/2012 12:00:00 AM			PC Approved	03/09/2012 12:00:00 AM	ADDRESS	34.03313	-118.22984	Lighting for a new restroom and mezzanine for an existing warehouse.  PLAN CHECK ONLY for Energy, with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77369	15041-20000-05521	6600 N TOPANGA CANYON BLVD Suite 1026	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			02/25/2015 12:00:00 AM	08/05/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.19008	-118.60565	RETAIL TENANT SET UP W/ FLOORING CEILING, MILLWORK, FIXTURES AND STOREFRONT new lighting. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77370	14041-20000-28691	9600 N ARLETA AVE	91331	6	201B157   774	2621027023	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			10/16/2014 12:00:00 AM	10/16/2014 12:00:00 AM		Permit Expired	11/10/2016 12:00:00 AM	ADDRESS	34.24418	-118.42805	PV1 SFD. TOTAL SYSTEM SIZE 4.2KW AC USING TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. TOTAL OF 16 MODULES	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77371	18041-10000-45453	7215 N VAN NUYS BLVD	91405	6	183B149    44	2218024009	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	Commercial			11/29/2018 12:00:00 AM	12/18/2018 12:00:00 AM		Permit Finaled	03/04/2019 12:00:00 AM	ADDRESS	34.20178	-118.44895	TENANT IMPROVEMENT: CHANGE OF USE FROM OFFICE TO VET CLINIC FULL PLAN CHECK	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77372	16041-10000-43441	928 S WESTERN AVE #231	90006	10	132B193  1012	5093009022	C2-1	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Commercial			12/12/2016 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	06/01/2017 12:00:00 AM	ADDRESS	34.05485	-118.30886	Plan check for power and energy change to use from retail to dental office. Total area: 1593 sq ft.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77373	11041-10001-24169	6301 W 3RD ST #J1	90036	4	138B177  1133	5512003043	C2-2D-O, [T][Q]C2-2D	Central	Wilshire	Mid City West		2145.01	Electrical	Electrical	Commercial			03/14/2012 12:00:00 AM			PC Approved	03/14/2012 12:00:00 AM	ADDRESS	34.07243	-118.35963	Plan check for Delta 4 revision to approved plans. Changes to fixture type and Title 24 calculations.T.I. for existing retail (Anthropologie) in first floor.  Install general/emergency lightings.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77374	15041-20000-13023	7645 N ROYER AVE	91304	12	186B097    75	2014034046	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			04/30/2015 12:00:00 AM	04/30/2015 12:00:00 AM		Permit Finaled	06/08/2015 12:00:00 AM	ADDRESS	34.20967	-118.62791	Installation of new roof mounted solar PV array.  Total system size = 4 kWac.  Microinverter system.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77375	09041-20001-24723	15301 W LANARK ST	91406	6	189B145    41	2654037029	R4-1	South Valley	Reseda - West Van Nuys			1275.20	Electrical	Electrical	Apartment			03/07/2011 12:00:00 AM			Corrections Issued	05/27/2011 12:00:00 AM	PIN	34.2183683	-118.4669973	"REVISION TO PREVIOUSLY SUBMITTED TO PLANS. NEW 87-UNIT ""AFFORDABLE SENIOR HOUSING""Note: Permit under 09041-20000-24723"	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77376	17041-20000-15736	900 S AVENUE 60	90032	14	150A233   236	5312015066	[Q]R1-1D	East Los Angeles	Northeast Los Angeles	LA-32	YES	2013.02	Electrical	Electrical	1 or 2 Family Dwelling			05/11/2017 12:00:00 AM	06/07/2017 12:00:00 AM		Permit Finaled	07/10/2017 12:00:00 AM	ADDRESS	34.10395	-118.17811	PV1.  Install 11.56 kW DC STC roof mounted grid tied PV system.  (34) modules with 11.4 kW rated string inverter with power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77377	16041-20000-18686	11677 W SAN VICENTE BLVD #120-121	90049	11	132B145   497	4401018020	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.03	Electrical	Electrical	Commercial			05/27/2016 12:00:00 AM	08/09/2016 12:00:00 AM		Permit Finaled	12/12/2016 12:00:00 AM	ADDRESS	34.05404	-118.46492	Plan check for Title 24 Part 6 only.  Change of use from retail to restaurant. Total area: 1,947 sq ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77378	19041-10000-44635	2706 E CESAR E CHAVEZ AVE	90033	14	127-5A225  74	5180017002	C2-1-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2042.00	Electrical	Electrical	Commercial			10/31/2019 12:00:00 AM			PC Info Complete	10/31/2019 12:00:00 AM	ADDRESS	34.04493	-118.20391	PLAN CHECK ONLY FOR TITLE 24. SCOPE OF WORK INCLUDES FOR NEW LIGHTING AND CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77379	15041-10000-32980	12300 W VENICE BLVD	90066	11	111B153    92	4235023009	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2723.02	Electrical	Electrical	Commercial			10/06/2015 12:00:00 AM			PC Approved	10/06/2015 12:00:00 AM	ADDRESS	34.00408	-118.4323	Energy plan check for a commercial building (School of Rock) T.I ; Scope includes new lighting for in/outdoor only. Total area is 4530-SQ feet.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77380	12041-10002-08597	2160 E 7TH ST	90023	14	124-5A219 253	5171024006	M3-1	East Los Angeles	Boyle Heights	Boyle Heights		2060.50	Electrical	Electrical	Commercial			10/01/2012 12:00:00 AM	10/12/2012 12:00:00 AM		Permit Finaled	06/05/2013 12:00:00 AM	ADDRESS	34.03423	-118.22602	((((((((((  addition of more lites to title 24  10-01-12 m.z )))))))))))))))))  USING EXISTING BRANCH CIRCUITS IN NINE COOLER STORAGE ROOMS,INSTALLING COOLER-RATED LUMINAIRES, OCCUPANCY SENSORS, AND SWITCHES .INSTALLING STRIP LIGHTS ABOVEFOR MAINTENANCE PURPOSES.PLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77381	10041-10001-23683	6100 N WOODLEY AVE	91436	6	177B141     3	2251002903	OS-1XL, [Q]PF-1XL	South Valley	Encino - Tarzana	Encino, Lake Balboa		1390.00	Electrical	Electrical	Commercial			04/12/2011 12:00:00 AM	12/23/2011 12:00:00 AM		Permit Finaled	12/18/2012 12:00:00 AM	ADDRESS	34.18088	-118.48309	NEW MV DUCITBANKS, RELOCATED MANHOLES AND NEW CIRCUITS IN ORDER TO COMPLETE PROJECT TO PROVIDE NEW OVERFLOW TANKS)))))DISCONNECT THE EXISTING 4160V, 3PHASE FEEDERS TO THE EXISTING 2MVA TRANSFORMER (US-102) AND INSTALL NEW 750MCM FEEDERS TO CONNECT THE SAME TRANSFORMER TO A NEW LOCATION (BAY 2-9)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77382	16041-10000-18206	10918 N RESEDA BLVD	91326	12	210B125   631	2715002037	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			05/24/2016 12:00:00 AM	05/26/2016 12:00:00 AM		Permit Finaled	07/21/2016 12:00:00 AM	ADDRESS	34.26934	-118.53589	PV1, INSTALL NEW  5.6 KW DC / 4.80KW AC ROOF-MOOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(20) MODULES: SOLAR WORLD SW280 MONO(20) MICROINVERTERS: ENPHASE M250-60-2LL-S22	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77383	11041-10000-17651	1540 E ALCAZAR ST	90033	14	135A225    66	5201005002	C2-2	East Los Angeles	Northeast Los Angeles	Lincoln Heights		2033.00	Electrical	Electrical	Commercial			08/19/2011 12:00:00 AM			PC Approved	08/23/2011 12:00:00 AM	ADDRESS	34.06338	-118.20434	T.I.  Converting two classrooms (Room # 157 and # 158) into one classroom.  Existing lighting to remain but applicant will be adding additiona downlights.  Plan check is for energy only.  All items that are needed for permit have been entered under inspection.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77384	15041-20000-27176	18348 W MINNEHAHA ST	91326	12	204B125    23	2731014002	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	08/19/2015 12:00:00 AM		Permit Finaled	09/11/2015 12:00:00 AM	ADDRESS	34.25983	-118.53364	PV1. Install roof mounted PV system sized 3 kW. Interconnected with main service panel. (9) Trina Solar TSM-255 Modules(1) ABB PVI 3.0 Inverter	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77385	11041-20001-08573	5601 N DE SOTO AVE	91367	3	174B109   379	2149016025	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.02	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	03/27/2012 12:00:00 AM		Permit Finaled	01/08/2013 12:00:00 AM	ADDRESS	34.17126	-118.58861	Changes from previously approved plans.  Changes include relocate eight fire smoke dampers.   All changes are clouded on plans and indicate by DELTA-1.  *****Plan check for new branch circuits to existing subpanel for Kaiser Permanente Ambulatory Care Facilities.  Per applicant request, plan check for power only.*****	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77386	12041-10000-06008	3900 N STANSBURY AVE	91423	5	162B153  1094		RE40-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1417.00	Electrical	Electrical	Commercial			03/22/2012 12:00:00 AM	07/31/2012 12:00:00 AM		Permit Finaled	10/18/2013 12:00:00 AM	ADDRESS	34.14084	-118.44264	New 2-story private school.  Plan check for Power and Energy.  622A of load.  Plan check for Power and Energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77387	12041-10000-00278	600 W 7TH ST	90017	9	129A209   130	5144011019	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/05/2012 12:00:00 AM	01/05/2012 12:00:00 AM		Permit Finaled	06/01/2012 12:00:00 AM	ADDRESS	34.04728	-118.25685	Plan check installation for new PreAction System.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77388	16041-20001-13677	25825 S VERMONT AVE	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			11/09/2016 12:00:00 AM			PC Approved	11/09/2016 12:00:00 AM	ADDRESS	33.78808	-118.29535	[[ 11/9/16 CHANGES TO APPROVED SET. CHANGE TO THE INTERCONNECTION OF SOLAR FROM LINE SIDE TAP TO CONNECTING TO A FEEDER ON THE LOAD SIDE OF A DISTRIBUTION PANEL PER 2014 NEC. VARIANCE HAS BEEN SUBMITTED TO USE 2014 NEC IN LIEU OF 2011 NEC]]]]Plan check for a PV2 carport PV system. System size is 212 kWac and consists of (8) inverters, (920) modules, and (1) load center.Note: Building application has been created under 16014-20000-01760	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77389	17041-20001-35677	7214 W FOOTHILL BLVD	91042	7	202-5A199 484	2563016026	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM			PC Approved	02/28/2018 12:00:00 AM	ADDRESS	34.24853	-118.28905	2/282018first time tenant.  plan check for power only.  energy plan check and full electrical fees will be covered under master application 17041-20000-35677.This is plan check only.  (((Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a change of use from retail to office/tenant improvement. Total lighting area = 1,789 sq. ft.)))Note: Building application has been generated under 17016-20000-26691	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77390	17041-10000-26106	11901 W FOOTHILL BLVD	91342	7	210B165    32	2531016014	A2-1-CUGU	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Foothill Trails District		1041.08	Electrical	Electrical	Commercial			08/01/2017 12:00:00 AM	08/01/2017 12:00:00 AM		Issued	08/01/2017 12:00:00 AM	ADDRESS	34.27521	-118.39555	TITLE 24 PLAN CHECK FOR REMOVAL OF (21) HID FIXTURES AND REPLACING WITH LED LIGHTING - TOTAL AFECTED AREA = 42,800 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77391	16041-30000-16656	1426 N SUMMITRIDGE DR	90210	5	147B157   404	4355007045	RE15-1	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2611.02	Electrical	Electrical	1 or 2 Family Dwelling			05/12/2016 12:00:00 AM			Reviewed by Supervisor	05/27/2016 12:00:00 AM	ADDRESS	34.09627	-118.42005	Plan check for power only. Project site is a new single-family dwelling. Work includes a new 1,000-amp service, (11) panel boards, associated loads, and (1) generator. Note: An electrical plan check has already been done for this project. There has been a complete redesign of the electrical system and there has been a change of engineer. New application has been created per E.M. Permit has been pulled on that original appliaction. Application number is 15041-20000-04472.Note: Building permit has been pulled under 12010-10000-02533	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77392	15041-20000-34139	13628 W ADDISON ST	91423	4	171B157  1081	2359017014	R1-1-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1246.00	Electrical	Electrical	1 or 2 Family Dwelling			10/14/2015 12:00:00 AM	10/14/2015 12:00:00 AM		Permit Finaled	10/27/2015 12:00:00 AM	ADDRESS	34.16113	-118.43004	PV1. NEW SOLAR ROOF MOUNTED SYSTEM. TOTAL SYSTEM SIZE IS 3.84 KWac.  (16) MODULES-SOLARWORLD SW 280 MONO(16) MICROINVERTERS-ENPHASE-M250-60-2LL	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77393	18041-10000-34771	7030 N HAYVENHURST AVE	91406	6	183B137   202	2224017024	M1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		9800.08	Electrical	Electrical	Commercial			09/12/2018 12:00:00 AM	09/12/2018 12:00:00 AM		Issued	09/12/2018 12:00:00 AM	ADDRESS	34.1984	-118.4922	REMOVE INDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77394	14041-20000-21758	12057 N HAVANA AVE	91342	7	216B149   333	2611017018	RS-1	North Valley	Sylmar	Sylmar		1066.48	Electrical	Electrical	1 or 2 Family Dwelling			08/12/2014 12:00:00 AM	08/12/2014 12:00:00 AM		Permit Finaled	08/28/2014 12:00:00 AM	ADDRESS	34.28954	-118.45436	PV1Central/String Inverter standard plan.Install roof-mounted solar array on SFD, interconnect with MSP.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(24) Trina Solar TSM-255 pv modules(24) SolarEdge P300 power optimizers	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77395	17041-10000-25142	1101 W MARTIN LUTHER KING, JR BLVD	90037	8	114B197   147	5037025019	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2312.20	Electrical	Electrical	Apartment			07/25/2017 12:00:00 AM	07/26/2017 12:00:00 AM		Permit Finaled	08/21/2018 12:00:00 AM	ADDRESS	34.01106	-118.29422	PLAN CHECK FOR FA IN AN 4 STORY APARTMENT BUILDING.SCOPE INCLUDES 134 DEVICES AND 3 PANELS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77396	16041-10000-14382	12311 W MIRANDA ST	91607	2	174B165   369	2340022004	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	06/10/2016 12:00:00 AM	ADDRESS	34.17452	-118.40117	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.7KWac.(20)MODULES-LG ELECTRONICS LG300A1C-B3	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77397	19041-10000-50762	2581 E CHAUCER ST BUILDING 3	90065	1	145-5A217 517	5445031***	[Q]CM-1-CDO-RIO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1871.02	Electrical	Electrical	Apartment			12/23/2019 12:00:00 AM	09/03/2020 12:00:00 AM		Permit Finaled	07/28/2021 12:00:00 AM	PIN	34.0949861	-118.23281575	FULL PLAN CHECK FOR POWER AND ENERGY. SCOPE OF WORK INCLUDES A SERVICE OF 400 AMPS, 120/208 V, 3-PHASE 4W. TOTAL AFFECTED AREA: 4763 SQ FT5 BUILDINGS ARE CONNECTED TO 1 SERVICE SEE COMMENTS.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77398	12041-20000-16072	16700 W GLEDHILL ST	91343	12	198B137   131	2687015008	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2012 12:00:00 AM	08/21/2012 12:00:00 AM		Permit Finaled	11/19/2012 12:00:00 AM	ADDRESS	34.24232	-118.49604	Plan check roof mounted 4.8KW P.V. system with (Enphase M215 Microinverter). Single family dwelling.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77399	19041-10000-51951	823 S UNION AVE	90017	1	130-5A205 167	5142017005	R3-1	Central	Westlake	Westlake South		2094.03	Electrical	Electrical	Commercial			12/17/2019 12:00:00 AM	12/17/2019 12:00:00 AM		Issued	12/17/2019 12:00:00 AM	ADDRESS	34.05174	-118.27284	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77400	17041-10003-16883	730 S SERRANO AVE 1-28	90005	10	132B193   438	5093014020	R4-2	Central	Wilshire	Wilshire Center - Koreatown		2125.02	Electrical	Electrical	Apartment			10/30/2019 12:00:00 AM	11/12/2019 12:00:00 AM		Permit Closed	05/08/2020 12:00:00 AM	ADDRESS	34.05884	-118.30642	CHANGES TO APPROVED SET, SCOPE OF WORK IS REMOVING HEAT PUMPS FROM CERTAIN UNITS, AND REPLACING THEM WITH SPLIT HEAT PUMPS. LOAD CALCULTIONS HAVE BEEN UPDATED ACCORDINGLY. ALL CHANGES ARE CLOUDED UNDER DELTA 3	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77401	15041-10000-27150	4800 N HEAVEN AVE	91364	3	168B093   161	2074031014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.02	Electrical	Electrical	1 or 2 Family Dwelling			08/19/2015 12:00:00 AM	09/18/2015 12:00:00 AM		Permit Finaled	09/28/2015 12:00:00 AM	ADDRESS	34.15756	-118.63219	PV1INSTALL ROOF MOUNTED PV SYSTEM SIZED 11.4KW INTERCONNECTED WITH MSP.(47) REC SOLAR MODULES(1) SOLAREDGE 11400 AMP INVERTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77402	16041-20000-27442	11442 W VICTORY BLVD	91606	2	180B169  1159	2335021011	[Q]R3-1	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1241.04	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM	03/15/2017 12:00:00 AM		Permit Finaled	10/20/2020 12:00:00 AM	ADDRESS	34.18641	-118.38048	Plan check for New appartment Building 17 units 3 story.Note: Fire alarm has been submitted.Building P# 15010-20000-04256	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77403	18041-10000-31226	8943 N OSO AVE Unit B	91311	12	195B113    39	2781001016	MR2-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1134.21	Electrical	Electrical	Commercial			08/16/2018 12:00:00 AM	11/06/2018 12:00:00 AM		Permit Finaled	05/16/2019 12:00:00 AM	ADDRESS	34.23374	-118.57549	FULL PLAN CHECK (POWER+ENERGY) TO REPAIR OF FIRE DAMAGED INDUSTRIAL BLDG TO A CORE AND SHELL CONDITION. COMPLETELY OVER 500A OF NEW LOADS  ARE CONNECTED TO (E) 600A SWITCHBOARD, NEW PANELBOARDS AND HVAC LOADS. TOTAL AREA: 4,429 SQ.FT(B# 18016-70000-24067)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77404	17041-20002-17215	13113 W VAN NUYS BLVD	91331	7	210B161   744	2535018018	[Q]C2-1VL-O-CDO	North Valley	Arleta - Pacoima	Pacoima		1043.20	Electrical	Electrical	Commercial			04/30/2018 12:00:00 AM	05/02/2018 12:00:00 AM		Permit Closed	10/24/2018 12:00:00 AM	ADDRESS	34.26875	-118.41881	Revisions to approved core and shell drawings.  Additional subpanel for each unit.  Loads shown on panel schedule under separate TI permit.  Approval for revisions on sheets E-07 and E-08 only.  (((PLANCHECK FOR POWER AND ENERGY.  NEW 2 STORY COMMERCIAL BLDG. methane zone. 1076 sqft indoor common areas + 5182 sqft outdoorbuilding permit # 07010-20000-00829)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77405	18041-20000-43631	20216 W ROSCOE BLVD unit 3	91306	3	192B113   610	2107001***	(Q)R3-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1341.03	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM			PC Approved	11/14/2018 12:00:00 AM	ADDRESS	34.21999	-118.5736	pv2install roof mounted pv system sized 2.5KW AC interconnected with msp.this is plan check only.  permit fees paid under application number 18041-90000-40660	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77406	16041-20001-17381	171 S NORMANDIE AVE	90004	10	138B193  1263	5518002040	R3-1	Central	Wilshire	Wilshire Center - Koreatown		2114.20	Electrical	Electrical	Commercial			05/17/2016 12:00:00 AM			PC Approved	06/01/2016 12:00:00 AM	ADDRESS	34.07169	-118.30055	EXPEDITE PER CUSTOMER REQUEST.PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 40KW INTERCONNECTED WITH MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77407	19041-20000-28225	16633 W VENTURA BLVD ste 711	91436	5	168B137   279	2259012017	C4-1L	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	Commercial			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Permit Finaled	09/26/2019 12:00:00 AM	ADDRESS	34.15823	-118.49571	ti to an existing commercial building (high rise) adding ne lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77408	15041-10001-15836	20943 W SATICOY ST	91304	3	186B109   218	2109023003	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Canoga Park		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2015 12:00:00 AM			PC Approved	06/09/2015 12:00:00 AM	ADDRESS	34.20845	-118.58994	EXPEDITED APPLICATION.<<<PV1 INSTALL 5.232 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOME INTERCONNECT WITH MAIN SERVICE PANEL.(16) MODULES:SUNPOWER SPR327NE-WHT-D(1) INVERTER ABB PVI-5000-TL-OUTD-US-A>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77409	14041-20000-03744	10724 N LOUISE AVE	91344	12	207B133   358	2696027020	R1-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.02	Electrical	Electrical	1 or 2 Family Dwelling			02/10/2014 12:00:00 AM	02/14/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.26554	-118.51083	PV1, ROOF-MOUNTED SOLAR INSTALLATION, INTERCONNECTING WITH NEW 200AMP SERVICE. SYSTEM SIZED @ 4.25 kW DC, 3.67 kW AC, WITH (17) MODULES AND MICROINVERTERS (M215-ENPHASE) ON AN LADBS MICROINVERTER STANDARD PLAN. (2) PERMITS PULLED UNDER :13041-10000-30076 (17 modules and inverter paid)13041-30000-32870 (200A panel paid)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77410	10041-10001-09475	14006 W RIVERSIDE DR #244 & 301	91423	4	168B153   454	2269025***	(Q)C2-1L, C2-1L, QC2-1L	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/23/2010 12:00:00 AM			PC Approved	11/23/2010 12:00:00 AM	ADDRESS	34.15713	-118.43792	Slight modifications, see delta 4A,  to previously approved set of plans, no major changes to the electrical system or the lighting sytems.  See previously approved set of plans.   Note many delta 3A modifications were changed to delta 4A on this set of plans, however there were not changes.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77411	13041-10000-25489	400 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport, Westchester - Playa del Rey	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/16/2013 12:00:00 AM	12/03/2013 12:00:00 AM		Permit Finaled	12/11/2018 12:00:00 AM	ADDRESS	33.94221	-118.40701	PROVIDE NEW LIGHTING AND POWER IN THE REMODELED AREA. PROVIDE POWER TO HVAC UNIT, ELEVATOR AND ESCALATOR.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77412	19041-10000-28651	9534 W BOLTON ROAD	90034	5	126B165    71	4309009012	R1V2-O	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			07/26/2019 12:00:00 AM	09/16/2019 12:00:00 AM		Permit Finaled	11/27/2019 12:00:00 AM	ADDRESS	34.04499	-118.39646	[eplan]PLAN CHECK FOR ROOF MOUNTED 5.2KVA SYSTEM CONSISTING OF 1 CENTRAL INVERTER(SOLIVIA 5.2 TL) WITH 17 MODULES(HANWHA Q-CELL SC315W) INCLDING RAPID SHUTDOWN DEVICES AND 1 ESS(TESLA POWERWALL)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77413	15041-20003-23168	7557 N GENESTA AVE	91406	6	186B133   260	2203015001	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			03/22/2017 12:00:00 AM			PC Approved	03/22/2017 12:00:00 AM	ADDRESS	34.20815	-118.50339	3.22.2017 - Changes to approved standard plan. Inverter output OCPD rating shall be 35A. Only change.=======Permit was pulled under Express Permit (15041-70000-23168). This is Plan check only per inspector's request.*Using Standrad Plan<Install a roof mounted photovoltaic system to existing single family dwelling  (6.37     KW)Solar device(s) is/are roof mounted and do not exceed the existing building height at the highest point. The solar PV installation shall comply with Los Angeles Fire Department's Fire Prevention Bureau (FPB) Requirement No. 96.>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77414	14041-20000-06161	541 S SPRING ST	90013	14	129A211   280	5149035015	C5-4D, [Q]C5-4D-CDO	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			03/06/2014 12:00:00 AM	10/28/2014 12:00:00 AM		Issued	10/28/2014 12:00:00 AM	ADDRESS	34.04657	-118.2507	NEW 2000A SERVICE FOR EXISTING ADAPTIVE REUSE BUILDING. THIS SERVICE IS FOR RETAIL TENANTS ONLY. PLAN CHECK FOR POWER ONLY. NO LOADS AT THIS TIME. SERVICE ONLY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77415	19041-10000-48916	8372 N TOPANGA CANYON BLVD	91304	3	192B101   469	2779043035	(Q)C1.5-1L, C2-1L, P-1L	North Valley	Chatsworth - Porter Ranch	Canoga Park		1132.33	Electrical	Electrical	Commercial			11/26/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Permit Finaled	12/26/2019 12:00:00 AM	ADDRESS	34.22187	-118.60576	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77416	09041-20006-07787	127 S SAN VICENTE BLVD	90048	5	138B173   613	4334006016	[T][Q]C2-2D-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			12/13/2012 12:00:00 AM			PC Approved	12/13/2012 12:00:00 AM	ADDRESS	34.07457	-118.37864	"Modification to previously approved set of plans.  PLAN CHECK ONLY for ""DELTA 218"".         <<<T. I. - new medical office bldg.(NEW HIGH RISE BUILDING, MEDICAL OFFICE, SHELL UNDER PCIS 08041-20000-22411)>>>"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77417	11041-20000-03843	4846 W HOLLYWOOD BLVD	90027	13	147B197   269	5543009021	C2-1D, RD1.5-1XL	Central	Hollywood	East Hollywood, Greater Griffith Park	YES	1912.01	Electrical	Electrical	Commercial			03/01/2011 12:00:00 AM	03/31/2011 12:00:00 AM		Permit Finaled	05/23/2011 12:00:00 AM	ADDRESS	34.10155	-118.29588	T.I. to pharmacy.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77418	17041-20000-23716	6063 W MELROSE AVE	90038	4	141B185   585	5533036013	C4-1XL	Central	Hollywood	Greater Wilshire		1918.20	Electrical	Electrical	Commercial			07/13/2017 12:00:00 AM	10/12/2017 12:00:00 AM		Permit Finaled	12/06/2017 12:00:00 AM	ADDRESS	34.08357	-118.33262	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT. CHG USE TO RETAIL/GROOMING. 2757 INDOOR SQFT + 2940 OUTDOOR SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77419	19041-10000-04875	10565 N NORTHRIDGE HILL DR	91311	12	207B117   504	2708015026	(T)(Q)RA-1, (T)(Q)RE40-1	North Valley	Chatsworth - Porter Ranch	Chatsworth, Northridge West	YES	1131.02	Electrical	Electrical	Commercial			02/11/2019 12:00:00 AM	12/10/2019 12:00:00 AM		Permit Closed	06/10/2021 12:00:00 AM	ADDRESS	34.26213	-118.56287	Title 24 plan check.  Installation of private tract site lighting in new development(Tract No 51798).  Lighting area = 8918 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77420	18041-20001-19184	10618 N COLLETT AVE	91344	12	207B141   510	2668007002	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1097.00	Electrical	Electrical	1 or 2 Family Dwelling			05/23/2018 12:00:00 AM			PC Approved	05/29/2018 12:00:00 AM	ADDRESS	34.26345	-118.48349	Expedited plan check fee.PV1.  Install 17.875 kW roof mounted grid tied PV system.  (55) modules with (2) 7.6 kW rated string inverter.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77421	10041-10000-25432	515 S FLOWER ST	90071	9	130-5A209 118	5151023400	C2-4D	Central	Central City	Downtown Los Angeles	YES	2077.10	Electrical	Electrical	Commercial			12/22/2010 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	04/06/2012 12:00:00 AM	ADDRESS	34.05134	-118.25661	Hight voltage installation of  new transformer for chiller unit.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77422	17041-10000-33126	2315 S CENTRAL AVE	90011	9	120A211   423	5131020001	[Q]C2-1VL	South Los Angeles	Southeast Los Angeles	South Central		2264.20	Electrical	Electrical	Commercial			09/15/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	10/16/2017 12:00:00 AM	ADDRESS	34.02099	-118.25404	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES T -24 ONLY. TOTAL AFFECTED AREA 8925 SQ.FT (OUT)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77423	15041-20000-01658	23130 W VENTURA BLVD	91364	3	171B097   747	2042006077	C1-1VLD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	9304.01	Electrical	Electrical	Commercial			01/20/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	10/14/2015 12:00:00 AM	ADDRESS	34.16312	-118.62954	T.I. to existing building of bowling alley bar.  Install general/emergency lighting.  Plan check for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77424	17041-20001-21937	4405 N MEDLEY PL	91316	5	165B129   136	2184036023	RA-1	South Valley	Encino - Tarzana	Encino	Yes	1397.03	Electrical	Electrical	1 or 2 Family Dwelling			06/29/2017 12:00:00 AM			PC Approved	07/07/2017 12:00:00 AM	ADDRESS	34.15046	-118.52432	expeditepv1install roof mounted pv system sized 15.2kw interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77425	13041-10001-34482	6220 N TOPANGA CANYON BLVD BLD #E	91367	3	177B101    81	2146005015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.13	Electrical	Electrical	Commercial			02/18/2015 12:00:00 AM			PC Approved	06/22/2015 12:00:00 AM	ADDRESS	34.1841	-118.60553	Changes to an approved set of plans. Changes include relocating load circuits. No new circuits or panels added. All changes are clouded. Approved for submittal per F.Y.*****Previous Work Description*****PLAN CHECK FOR POWER AND ENERGY FOR A NEW BUILDING. CORE AND SHELL.WESTFIELD MALL. BUILDING E.BUILDING PERMIT # 13010-10000-02908.New 2 STORY retail/restaurant bldg.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77426	14041-10001-08999	5506 N MORELLA AVE	91607	2	174B169  1086	2348005009	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM			PC Approved	04/29/2014 12:00:00 AM	ADDRESS	34.17059	-118.38982	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, INSTALL 8 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOME, INTERCONNECT WITH MAIN SERVICE PANEL.(2) TRANSFORMERLESS INVERTERS: SOLAREDGE SE3800A-US-ZB-U &(32) MODULES: YINGLI YL250P-29b}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77427	15041-20000-38554	11747 W OTSEGO ST	91607	2	171B169   590	2355005049	R1-1	South Valley	North Hollywood - Valley Village	Valley Village		1251.00	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/19/2015 12:00:00 AM		Permit Finaled	12/21/2015 12:00:00 AM	ADDRESS	34.16318	-118.38945	PV1.  Install 5.565 kW roof-mounted, utility-interactive PV system - (21) Kyocera KU2656ZPA modules and (1) ABB PVI-5000 transformerless inverter.  Central inverter standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77428	14041-10002-12882	990 W 8TH ST	90017	14	129A207    91	5144022021	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM			PC Approved	03/26/2015 12:00:00 AM	ADDRESS	34.0484	-118.26248	changes to an approve set of plans. changes noted delta 4 and delta 5. Relocation FA devices.  CHANGES TO APPROVED SET,  ADDING 4 DEVICES TO EXISTING FIRE ALARM SYSTEM. PERMIT IS EXISTING, THIS IS A PLAN CHECK ONLY(((NEW FA FOR parking structure. not a highrise per building application.)))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77429	19041-10000-07688	5805 E YORK BLVD	90042	14	154-5A229  93	5484009012	[Q]C2-1XL	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1832.20	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	05/21/2020 12:00:00 AM		Permit Finaled	12/01/2022 12:00:00 AM	ADDRESS	34.11871	-118.19187	FULL PC FOR POWER AND ENERG. SCOPE INCLUDES NEW 600A 120/240V SERVICE/DISTRIBUTION BOARD, NEW PANELS, AND NEW CIRCUITS. TOTAL AFFECTED AREA IS 2713 SQ. FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77430	18041-10000-46963	3246 S BARBYDELL DR	90064	5	123B165   645	4316025009	R1V2	West Los Angeles	West Los Angeles	Westside		2690.00	Electrical	Electrical	1 or 2 Family Dwelling			12/11/2018 12:00:00 AM	01/07/2019 12:00:00 AM		Permit Finaled	12/11/2019 12:00:00 AM	ADDRESS	34.0332	-118.40325	PC FOR NEW 10KW ROOFTOP PV SYSTEM AND 28KW ENERGY STORAGE SYSTEM, SCOPE INCLUDES (2) TESLA POWER WALL BATTERIES, (28) PV MODULES, AND (1) SE10000A INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77431	11041-10000-26461	7563 W BEVERLY BLVD	90036	5	138B177   410	5526041014	C2-1VL-O	Central	Wilshire	Mid City West		2144.00	Electrical	Electrical	Commercial			12/12/2011 12:00:00 AM	04/26/2012 12:00:00 AM		Permit Finaled	11/27/2012 12:00:00 AM	ADDRESS	34.0763	-118.35479	Shell only to an Office/Dry storage/Food Distribution with at change of use to a FUTURE restaurant.  for Energy (Lighting, with Emergency lighting).  <<<<<Tenant space will require a full plan check once a tenant moves in.>>>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77432	18041-20000-38352	15821 W VENTURA BLVD Ste 320	91436	5	168B141   597	2261011017	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	02/14/2019 12:00:00 AM	ADDRESS	34.15584	-118.47812	Existing commercial office remodel in highrise building.  New lights connected to existing circuits.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77433	13041-20001-26351	17037 W PLUMMER ST	91325	12	201B133   599	2692002030	A2-1	North Valley	Northridge	Northridge East	YES	1151.01	Electrical	Electrical	Commercial			09/23/2013 12:00:00 AM			PC Approved	11/06/2013 12:00:00 AM	ADDRESS	34.24317	-118.50383	((EXPEDITE FEES ONLY))210kw roof mount Commercial PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77434	16041-10001-45766	380 WORLD WAY MSC-Gateway	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/10/2019 12:00:00 AM			Verifications in Progress	06/21/2019 12:00:00 AM	ADDRESS	33.94373	-118.40888	Plan Check Only. DCN X** changes to an approved set. Changes include modification to circuit and load update. Original Scope of Work: (Plan check for power and Title-24.  Provide normal and emergency power to LAX MSC gateway building.Building permit #16014-10000-02498)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77435	19041-20000-12590	8941 N HASKELL AVE	91343	12	195B141   234	2672007024	RS-1	North Valley	Mission Hills - Panorama City - North Hills	North Hills West		1174.04	Electrical	Electrical	1 or 2 Family Dwelling			04/08/2019 12:00:00 AM	04/08/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.23313	-118.47653	Plan check for PV roof mounted system, System size: 10.88KW AC, 12.24KW DC with 34 PV Modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77436	16041-20000-42400	14596 W DEERVALE PL	91403	4	162B149   432	2275031013	RE15-1-H	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks	Yes	1416.00	Electrical	Electrical	1 or 2 Family Dwelling			12/02/2016 12:00:00 AM	12/13/2016 12:00:00 AM		Permit Finaled	01/09/2017 12:00:00 AM	ADDRESS	34.13889	-118.4527	Plan check for a PV1 roof-mounted PV system. System size is 11.9 kWac and consists of (33) AC PV modules and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77437	14041-10001-09080	4630 W GAINSBOROUGH AVE	90027	4	153B197   572	5588025027	RS-1	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM			PC Approved	04/17/2014 12:00:00 AM	ADDRESS	34.11218	-118.29093	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 6 kW DC roof-mounted solar array, interconnect with main service panel. (1)Transformerless inverter:Solaredge SE6000A-US-ZB-U.(24) Modules: CANADIAN SOLAR CS6P-250PX}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77438	16041-10000-27514	12582 W MILLENNIUM	90094	11	102B161  1292	4211010117	M(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			08/03/2016 12:00:00 AM			PC Approved	08/03/2016 12:00:00 AM	ADDRESS	33.97749	-118.41246	PC for Title 24, energy only. Existing 3 story office building converting multiple office spaces to private movie viewing room. New lighting and power. Total sqft = 970.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77439	12041-10002-10024	504 S HARBOR BLVD	90731	15	015B201   221	7440030***	[Q]M2-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			07/30/2013 12:00:00 AM			PC Info Complete	03/13/2014 12:00:00 AM	ADDRESS	33.74047	-118.27853	PLAN CHECK FOR REVISION DELTA A TO APPROVED PLANS. CHANGES CONSISTS OF :444 S HARBOR(FIRE HOUSE)-REPLACE MENT OF TWO PANELS.BERTH 84 (MUSEUM) - RELOCATING OF EXISTING PANELS. SEPARATE PERMIT SHALL BE OBTAINED FOR EACH BUILDING.NOTE: PErmitnis pulled under 12041-10000-10024 and 12041-10002-10024.  This job is plan check only no need for new permit, original permit is still active	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77440	17041-10000-16649	1202 E ANAHEIM ST	90744	15	030B213   132	7424023001	[Q]M2-1VL-O-CUGU	Harbor	Wilmington - Harbor City	Wilmington		2947.01	Electrical	Electrical	Commercial			05/18/2017 12:00:00 AM	05/18/2017 12:00:00 AM		Permit Finaled	06/27/2017 12:00:00 AM	ADDRESS	33.78064	-118.24789	T24 ONLY. REPLACE (E) LIGHT FIXTURES WITH (N) LED LIGHT FIXTURES. TOTAL AREA 16700 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77441	19041-10001-01630	10512 W MAGNOLIA BLVD	91601	4	171B177   702	2419020004	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Greater Toluca Lake		1256.00	Electrical	Electrical	Commercial			01/15/2019 12:00:00 AM			PC Approved	01/22/2019 12:00:00 AM	ADDRESS	34.16476	-118.3598	EXPEDITE FEESPV PLAN CHECK FOR 6.930KW(DC) AND 6KW(AC) COMMERCIAL. 22 MODULES (Q.CELLS Q.PEAK DUE-G5 315). 22 OPTIMIZERS SOLARE EDGE P320.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77442	19041-20000-03049	24352 W STONE BEND LANE	91304	12	192B089   225	2017038026	RE9-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hill, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/25/2019 12:00:00 AM	01/25/2019 12:00:00 AM		Permit Finaled	05/22/2019 12:00:00 AM	ADDRESS	34.22005	-118.65613	Plan check for a PV1 roof-mounted PV system. System size 7.56 kWdc/7.6 kWac and consists of (1) inverter and (24) modules. MSP is rated for 400 Amps.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77443	16041-20000-24470	201 N FIGUEROA ST 5th fl	90012	14	133-5A211 254	5161006908	C4-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			07/12/2016 12:00:00 AM	07/13/2016 12:00:00 AM		Permit Finaled	08/25/2016 12:00:00 AM	ADDRESS	34.05859	-118.25142	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO EXISTING PANELS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHITNG.  TOTAL SQUARE FOOTAGE 4479.  SCOPE OF WORK TO BE PERFORMED IN THE 5TH FLOOR.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77444	16041-10000-44546	10250 W SANTA MONICA BLVD # 2730	90067	5	132B161   512	4319003066	C2-1L-O, C2-1VL-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			12/20/2016 12:00:00 AM	02/16/2017 12:00:00 AM		Permit Finaled	05/27/2017 12:00:00 AM	ADDRESS	34.05949	-118.42045	"Full PC for 1st time Tenant ""American Eagle"" Ste. 2730.  Install new Xrfmr, and  panels, total area 8,005 sq.ft. T-24 using performance method.*New connected load 160A to DB ELA40"	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77445	13041-10001-19351	5707-5709 N CAHUENGA BLVD	91601	2	174B177   301	2415024013	CR-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1243.00	Electrical	Electrical	Commercial			10/25/2013 12:00:00 AM			PC Approved	11/07/2013 12:00:00 AM	ADDRESS	34.17429	-118.36174	Change of fixtures from original lighting design.  (((CHANGE OF USE FROM OFFICE/WHSE TO OFFICE)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77446	18041-20000-37390	6652 N PLATT AVE	91307	12	180B093   288	2036026015	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			10/01/2018 12:00:00 AM	10/01/2018 12:00:00 AM		Permit Finaled	10/25/2018 12:00:00 AM	ADDRESS	34.19129	-118.64219	Plan check for a PV1 roof-mounted PV system. System size is 11.6 kWdc/11.4 kWac and consists of (1) inverter and (40) modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77447	17041-20000-05166	6300 W WILSHIRE BLVD SUITE 2150	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM	02/21/2017 12:00:00 AM		Permit Finaled	04/18/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	Plan check for energy only. TI to office on 21st floor. New lighting (incl. emergency) and receptacles. 7,648sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77448	16041-20000-21560	8380 N RUDNICK AVE	91304	12	192B101   429	2010002062	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.32	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2016 12:00:00 AM	06/21/2016 12:00:00 AM		Permit Expired	07/26/2018 12:00:00 AM	ADDRESS	34.22236	-118.61295	PV1. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 7.685.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77449	14041-10000-12141	6511 N WHITSETT AVE	91606	2	180B165   548	2325016023	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1237.00	Electrical	Electrical	1 or 2 Family Dwelling			05/07/2014 12:00:00 AM	06/11/2014 12:00:00 AM		Permit Finaled	07/14/2014 12:00:00 AM	ADDRESS	34.18897	-118.40555	PV1 ROOF MOUNTED TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 6.0KWAC.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77450	19041-30000-19229	700 S FLOWER ST 11th Floor	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			05/21/2019 12:00:00 AM	05/21/2019 12:00:00 AM		Permit Finaled	07/26/2019 12:00:00 AM	ADDRESS	34.04835	-118.25882	Plan check for Title 24 only. Project site is the common area corridors of the 11th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,714 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77451	18041-10001-27023	425 E SWINFORD ST	90731	15	021B201   197	7440024911	[Q]M3-1	Harbor	Port of Los Angeles	Central San Pedro		9800.31	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM			PC Approved	08/28/2019 12:00:00 AM	ADDRESS	33.7497	-118.27718	EXPEDITE PE APPLICANT REQUEST. Note: Permit is paid under the master application. Plan check only.  NEW PV SYSTEM MOUNTED ON CARPORTS WITH 3080 PV MODULES AND 34 INVERTERS WITH 480 VOLT OUTPUT. SYSTEM SIZE  1.34 MWDC/  980 KWAC<<<NOTE: THE STEP UP TRANSFORMER 480:34,500V BELONGS TO LADWP - NOT PART OF THIS PROJECT>>>>BUILDING PERMIT: 18010-40000-03433	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77452	16041-10000-10313	1219 S REDONDO BLVD	90019	10	129B181   153	5084031006	R2-1-O	Central	Wilshire	P.I.C.O.		2162.00	Electrical	Electrical	1 or 2 Family Dwelling			03/24/2016 12:00:00 AM	03/24/2016 12:00:00 AM		Permit Finaled	04/18/2016 12:00:00 AM	ADDRESS	34.05286	-118.34763	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 5.0KWac.(18)MODULES-CANADIAN SOLAR: CS6P-265P(1)INVERTER-SOLAREDGE TECHNOLOGIES SE5000 (240V)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77453	18041-20001-37112	15900 W VALLEYVIEW CT 15012 A,B,-C	91342	7	222B141   141	2604002037	M1-1	North Valley	Sylmar	Sylmar	YES	1066.04	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM			PC Approved	10/16/2018 12:00:00 AM	ADDRESS	34.30584	-118.47951	10/16/2018changes to an approved set of plans.  changes to provide isolated ground in all exam/patient care areas.  this is plan check only.  ((((ti to an existing commercial building.  adding new lighting new controls to existing panels.  plan check for indoor energy only.))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77454	17041-10000-43116	14006 W RIVERSIDE DR SPACE 272	91423	4	168B153   454	2269025***	(Q)C2-1L-RIO, C2-1L-RIO, P-1L-RIO	South Valley	Van Nuys - North Sherman Oaks	Sherman Oaks		1287.02	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM	03/19/2018 12:00:00 AM		Permit Finaled	07/06/2018 12:00:00 AM	ADDRESS	34.15713	-118.43792	Energy plan check for a retail T.I located in a commercial (Mall) building. Scope includes new lighting and equipment.  Total area is 5,290 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77455	11041-20000-12069	11611 W SAN VICENTE BLVD #515	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			06/13/2011 12:00:00 AM	06/13/2011 12:00:00 AM		Permit Finaled	07/12/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	T24 Energy (general/emergency) lighting for Interior tenant improvements in Suite #515	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77456	19041-20001-00074	18400 W RINALDI PL	91326	12	210B125    98	2715026057	RE11-1	North Valley	Northridge	Northridge East		1112.06	Electrical	Electrical	1 or 2 Family Dwelling			01/02/2019 12:00:00 AM			PC Approved	01/10/2019 12:00:00 AM	ADDRESS	34.27487	-118.53445	Expedited plan check fee.PV1.  Install 13.680 kW DC roof mounted grid tied PV system.  (38) AC modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77457	13041-20002-30768	7192 W ESTEPA DR PV1	91042	7	198B197   121	2562021007	RA-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga	YES	1014.00	Electrical	Electrical	1 or 2 Family Dwelling			01/23/2014 12:00:00 AM			PC Approved	01/23/2014 12:00:00 AM	ADDRESS	34.24227	-118.28902	"((((changes to approved set of plans. change for new location of service equipment. no change in DC side of the system. .due to senate bill, no fee for plan check))))New 18.639kw Photovoltaic System on the roof of an existing single family dwelling.  System is UNGROUNDED. ""$0 permit fee is due to the 2012 Senate Bill No. 1222"""	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77458	18041-20001-21263	13003 W VENTURA BLVD	91604	2	165B161   966	2375022059	C2-1VL-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Studio City		1439.02	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM			PC Approved	06/13/2019 12:00:00 AM	ADDRESS	34.1457	-118.41619	6/13/2019changes to an approved set of plans.  changes to reflect field conditions.  this is planc heck only.  changes noted delta 4 only.  ((((PLANCHECK FOR POWER AND ENERGY.  FIRST TIME TENANT FOR RESTAUARANT AFTER CORE AND SHELL.BUILDING PERMIT # 18016-10000-18203))))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77459	18041-10000-18609	1820 S OAK ST	90015	1	124-5A203  22	5124017002	C2-1VL-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			05/18/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	02/05/2020 12:00:00 AM	ADDRESS	34.03771	-118.27686	PLAN CHECK FOR TITLE 24 ONLY FOR REMOVAL OF HID FIXTURES AND REPLACE WITH NEW LED FIXTURES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77460	14041-10000-12712	12880 W CROWLEY ST	91331	6	195B161   174	2628024021	R1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1190.01	Electrical	Electrical	1 or 2 Family Dwelling			05/13/2014 12:00:00 AM	05/13/2014 12:00:00 AM		Permit Finaled	05/16/2014 12:00:00 AM	ADDRESS	34.23439	-118.41333	Install roof mounted solar array interconnected with main pannelsystem size = 5.1 kW	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77461	18041-10000-13650	803 E MARCO PL	90291	11	108B145   778	4241022036	R2-1	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	08/09/2018 12:00:00 AM	ADDRESS	33.993	-118.45919	PC FOR ROOF MOUNTED PV ON SFD. SCOPE INCLUDES 8  AC MODULES TOTAL SYSTEM SIZE SYSTEM SIZE 2.56KWAC	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77462	18041-10000-38206	750 S LAMAR ST GATE BLDG	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			10/05/2018 12:00:00 AM	11/20/2018 12:00:00 AM		Issued	11/20/2018 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD PROJECT . PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS ALL UNDER ONE PLANCHECK. THIS APPLICATION IS FOR THE (B) THE GATE BUILDING 2 OF 10BUILDING PERMIT # N/A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77463	17041-10002-04627	20101 W RINALDI ST BLDG S2	91326	12	213B113   266	2701004047	(T)C4-2D, [T]C4-2D	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	Commercial			08/23/2018 12:00:00 AM			PC Approved	08/29/2018 12:00:00 AM	ADDRESS	34.27545	-118.57197	CHANGES TO AN APPROVED SET OF PLANS. ALL CHANGES ARE CLOUDED UNDER DELTA  14, 25, & 28. CHANGES INCLUDE RELOCATING SITE/LANDSCAPE LIGHTING, ADDING LANDSCAPE LIGHTING, REVISING SINGLE LINE DIAGRAM TO REFLECT AS BUILT, REVISING PANEL SCHEDULES,  AND SPECIFYING EGC CONDUCTORS ON THE FLOOR PLANS.NOTE: PERMIT HAS BEEN PULLED UNDER MASTER APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77464	12041-10000-05565	1145 S GRAND AVE	90015	14	126A207   315	5139028***	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/12/2012 12:00:00 AM			PC Approved	03/12/2012 12:00:00 AM	ADDRESS	34.04067	-118.26314	Shell only, Lighting change and new panel/circuits.  No Emergency lighting, temporary shell only per engineer.  PLAN CHECK for Energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77465	15041-20000-13916	1020 N COLE AVE	90038	13	144B185   868	5533015018	MR1-1-SN	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Commercial			05/07/2015 12:00:00 AM	05/07/2015 12:00:00 AM		Permit Finaled	12/11/2015 12:00:00 AM	ADDRESS	34.08956	-118.32972	TI TO SUITE 4290. NEW OFFICES. NEW LIGHTING. PC FOR ENERGY ONLY. T24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77466	14041-20001-32225	10510 N WYSTONE AVE	91326	12	207B121   691	2728016033	RA-1	North Valley	Northridge	Northridge West	YES	1112.04	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2014 12:00:00 AM			PC Approved	12/08/2014 12:00:00 AM	ADDRESS	34.26167	-118.54813	EXPEDITE PER APPLICANT REQUEST[PV1Install a roof-mounted solar array on a SFD. Interconnect with 200A MSP.System size: 6kW. Ungrounded system.18 327W pv modules across 3 strings (5+5+8).]	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77467	11041-10000-01427	1 S LMU DR 1ST FL	90045	11	099B157     9	4113026007	[Q]R4-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.01, 2765.00	Electrical	Electrical	Commercial			01/24/2011 12:00:00 AM	02/25/2011 12:00:00 AM		Permit Finaled	05/04/2011 12:00:00 AM	ADDRESS	33.96577	-118.42406	TENANT IMPROVEMENTS  IN OFFICESPLAN CHK IS FOR TITLE 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77468	13041-10000-34623	2141 S WESTWOOD BLVD	90025	5	126B153   239	4322001019	C4-1VL-POD	West Los Angeles	West Los Angeles	Westside		2672.00	Electrical	Electrical	Commercial			12/12/2013 12:00:00 AM	12/12/2013 12:00:00 AM		Permit Finaled	03/10/2014 12:00:00 AM	ADDRESS	34.04413	-118.43223	Remove HID light fixtures and replace with new fluorescent fixtures in retail space.  Plan check for Title 24 lighting requirements and associated permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77469	10041-10000-24902	6303 N OWENSMOUTH AVE BSMNT	91367	3	177B105   123	2146029016	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1351.12	Electrical	Electrical	Commercial			12/14/2010 12:00:00 AM	01/03/2012 12:00:00 AM		Permit Finaled	02/13/2012 12:00:00 AM	ADDRESS	34.18474	-118.60182	REMOVING PANELBOARDS FROM SWBD AT 6301 OWENSMOUTH AND RECONNECT TO SWBD AT 6303 OWENSMOUTH	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77470	19041-10000-42959	4750 W WILSHIRE BLVD	90010	4	132B185    23	5507030015	CR(PKM)-1, RD3-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			10/22/2019 12:00:00 AM	11/26/2019 12:00:00 AM		Issued	11/26/2019 12:00:00 AM	ADDRESS	34.06185	-118.3338	Plan Check for fire alarm system. (1)Facp, (14)NAC, (284)devices	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77471	16041-10000-01369	710 W HARRY BRIDGES BLVD	90744	15	027B205   665	7440007901	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		9800.31	Electrical	Electrical	Commercial			01/14/2016 12:00:00 AM	01/14/2016 12:00:00 AM		Issued	01/14/2016 12:00:00 AM	ADDRESS	33.7693	-118.27062	New approval on previously (expired) approved plan under 14041-10000-06057, Design remain the same.***METHANE MITIGATION PLAN CHECK FOR  PORT OF LOS ANGELES.  ELECTRICAL PC# 13041-10000-28992	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77472	14041-10000-02867	380 E 15TH ST	90015	14	123A209    59	5133020008	M2-2D	Central	Central City	Downtown Los Angeles		2240.10	Electrical	Electrical	Commercial			01/31/2014 12:00:00 AM	01/31/2014 12:00:00 AM		Permit Finaled	02/24/2014 12:00:00 AM	ADDRESS	34.03251	-118.25919	T24 PART 6 ENERGY FOR COMMERCIAL SPACE. REMOVING HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. PROJECTED AREA IN SCOPE OF WORK IS APPROX. 3086 SQ FT. REMOVING A TOTAL OF 7 UNITS. ALL WORK WILL BE INTERIOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77473	18041-10000-26939	1422 W 259TH ST	90710	15	033B193   197	7411002030	[Q]MR1-1VL	Harbor	Wilmington - Harbor City	Harbor City		2933.07	Electrical	Electrical	Commercial			07/19/2018 12:00:00 AM	07/19/2018 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	33.78809	-118.30212	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77474	17041-10000-23451	21600 W OXNARD ST #720,730	91367	3	177B105    84	2146006043	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1371.03	Electrical	Electrical	Commercial			07/12/2017 12:00:00 AM	09/11/2017 12:00:00 AM		Permit Finaled	10/19/2017 12:00:00 AM	ADDRESS	34.179	-118.6002	PC FOR TENANT IMPROVEMENT FOR OFFICE IN A HIGH RISE BUILDING. TOTAL CONNECTED LOAD < 400A TITLE24 ENERGY ONLY.SOCPE INCLUDES NEW LIGHTS AND RECEPTACLES  WITH NEW SUB PANEL. TOTAL AFFECTED AREA 10967 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77475	16041-10000-39040	601 W 5TH ST STE R102	90071	14	130-5A211  92	5151017030	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/03/2016 12:00:00 AM	02/17/2017 12:00:00 AM		Permit Finaled	06/15/2017 12:00:00 AM	ADDRESS	34.05049	-118.25386	T-24, PC FOR ENERGY ONLY. TENANT IMPROVEMENT TO AN EXISTING RESTAURANT SPACE. SCOPE INCLUDES NEW LIGHT AND RECEPTACLES. TOTAL AFFECTED AREA IS 1945 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77476	17041-10000-45038	15318 W WHITFIELD AVE	90272	11	129B125   185	4422020024	R1H1	West Los Angeles	Brentwood - Pacific Palisades		YES	2625.01	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2017 12:00:00 AM	12/14/2017 12:00:00 AM		Permit Finaled	12/27/2017 12:00:00 AM	ADDRESS	34.0519	-118.5263	PC FOR ROOFMOUNTED PV ON SLD. SYSTEM SIZE 10.15 KWACSCOPE INCLUDES 35 PANELS WITH MICROINVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77477	19041-20000-38344	5628 N SEPULVEDA BLVD	91411	4	174B145   451	2243003009	C2-1VL-RIO	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1284.00	Electrical	Electrical	Apartment			09/24/2019 12:00:00 AM			PC Info Complete	03/04/2020 12:00:00 AM	ADDRESS	34.17296	-118.46593	Plan check for Power and energy for Mixed use retail/restaurant 20 unit Multi-family 3 story building. Total area: 75,972 sq ft. B#18010-20000-04477	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77478	13041-10001-07125	770 S GRAND AVE	90014	14	129A209   223	5144012051	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Apartment			04/02/2014 12:00:00 AM			PC Approved	04/13/2014 12:00:00 AM	ADDRESS	34.04594	-118.25757	revised permitted set of plans-valued engineering. relocate circuits to other panels and remove the former panels which were determined not required .other changes are clouded in the reviced set of plans7-STORY MIXED USED BUILDING 700 UNIT APARMENT, OVER 2-LEVEL SUBTERRANEAN GARAGE :  upper 6 levels residential and retail/gym on the 1st floor. None highrise.. 5000A SERVICE;__this note : by Nabil, this methane zone.  was indicated the level changed from 5 to 2.  see plan number 12041-10000-29828	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77479	17041-10000-09298	2535 S CRENSHAW BLVD	90016	10	123B185   583	5050010054	[Q]C2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	West Adams		2187.02	Electrical	Electrical	Commercial			03/23/2017 12:00:00 AM	03/23/2017 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.03318	-118.33503	PC for energy only, outdoor Title-24. Removing HID fixtures and replacing them with new LED ones. Area: 23,700.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77480	09041-10001-16499	7214 N WHITSETT AVE	91605	2	183B165     2	2324035001	C2-1VL	South Valley	North Hollywood - Valley Village	North Hollywood Northeast		1233.04	Electrical	Electrical	Commercial			07/21/2010 12:00:00 AM			PC Approved	08/30/2010 12:00:00 AM	ADDRESS	34.20184	-118.40481	Change the priviously approved plan for a Gas Station. Changes are shown with delta 3 & 4. plan check for changes.    ((((((((((((((((((((((New Chevron Gas Station w/ car wash, dispenser canopy, quick mart.  Permit is for new service, new panels, new xfmrs, new equipment, new ckts, and new lighting.  Wiring will be go through classified areas.  Variance for FA Separation Filed.  P/C is for Power and Energy.))))))))))))))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77481	13041-10000-23897	17503 S FIGUEROA ST	90248	15	063B201    64	7339007014	MR1-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2913.00	Electrical	Electrical	Commercial			09/03/2013 12:00:00 AM			PC Approved	09/03/2013 12:00:00 AM	ADDRESS	33.87162	-118.28189	permit to be pulled at EPC counter only. PC for energy only. TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN. For autoshop (NON-HAZARDOUS PER APPLICANT). 2 fixtures	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77482	19041-30001-13953	1611 S ELECTRIC AVE	90291	11	108B145  1414	4241037016	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			04/25/2019 12:00:00 AM	04/25/2019 12:00:00 AM		Permit Finaled	06/19/2019 12:00:00 AM	ADDRESS	33.99035	-118.4631	04/25/2019 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 5,652 sq. ft.Note: Building permit has been issued under 19016-10000-07371*****Original Work Description*****T.I. PLUGS/RECEPTACLES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77483	17041-10001-35318	7610 W DAY ST	91042	7	204A197   231	2558035037	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Sunland - Tujunga		1014.00	Electrical	Electrical	Commercial			07/25/2018 12:00:00 AM			PC Info Complete	07/25/2018 12:00:00 AM	ADDRESS	34.25444	-118.29835	Revision to approved set: revise light fixtures, update T24 info, add more circuits. All changes noted as Delta-2.<<CHANGE OF USE FROM RETAIL TO OFFICE- SUITES 100 &101PLAN CHECK IS FOR TITLE 24>>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77484	16041-20001-12529	8501 N SUNLAND BLVD	91352	6	192B177   196	2408014027	C2-1VL	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.01	Electrical	Electrical	Commercial			04/13/2018 12:00:00 AM	04/13/2018 12:00:00 AM		Permit Finaled	02/01/2024 12:00:00 AM	ADDRESS	34.22481	-118.36592	04/13/2018 Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,465 sq. ft.Note: Building permit application has been generated under 15010-10001-00284*****Previous Work Description*****CHANGE EXISTING PANEL NEW OUTLETS AND LED LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77485	18041-10000-19012	13570 N ELDRIDGE AVE	91342	7	228B157   742	2511002005	CR-1XL-CPIO	North Valley	Sylmar	Sylmar		1060.20	Electrical	Electrical	Commercial			05/22/2018 12:00:00 AM	05/22/2018 12:00:00 AM		Permit Finaled	06/20/2018 12:00:00 AM	ADDRESS	34.31872	-118.42539	T-24, PC FOR ENERGY ONLY. SCOPE INCLUDES REPLACING HID FIXTURES WITH LED LIGHTS FOR OUTDOOR USE. TOTAL AFFECTED IS 52000 SQ. FT.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77486	16041-10001-30395	2121 S AVENUE OF THE STARS #2050	90067	5	132B161   133	4315019005	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			09/02/2016 12:00:00 AM	09/23/2016 12:00:00 AM		Permit Finaled	12/01/2016 12:00:00 AM	ADDRESS	34.05554	-118.41342	09-02-16 Changes to an approved set of plans. Changes include remove scope of work in conference room and lobby. conference room and lobby lighting is existing to remain. *******Previous work description*****************************T-24, PC FOR ENERGY ONLY. TI TO AN EXISTING COMMERCIAL BUILDING FOR SUITE 2050. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES. TOTAL AFFECTED AREA SI 5666 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77487	10041-20000-16708	700 W CHILDS WAY 2ND-3RD	90089	8	118-5A201  23	5039024016	[Q]R4-1	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2227.00	Electrical	Electrical	Commercial			08/24/2010 12:00:00 AM	09/01/2010 12:00:00 AM		Permit Finaled	04/26/2011 12:00:00 AM	ADDRESS	34.01978	-118.28463	REVISION TO 09041 10000 23266. PLAN CHECK T-24 ENERGY FOR EXISTING RESTROOM AT USC JOHN HUBBARD HALL ON 2ND & 3RD FLOOR.  EXISTING TIME CLOCK AND CKTS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77488	16041-10001-00869	15926 W ENADIA WAY	91406	6	183B141   199	2224004050	R1-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1276.04	Electrical	Electrical	1 or 2 Family Dwelling			02/23/2016 12:00:00 AM			PC Approved	02/23/2016 12:00:00 AM	ADDRESS	34.19993	-118.48013	PV1. PC FOR A NEW SOLAR SYSTEM TO AN EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 10.0KWac(37)MODULES-REC SOLAR: REC275P(37)OPTIMIZERS-SOLAREDGE P300(1)INVERTER-SOLAREDGE SE 10000A-USNOTE: PERMIT PAID UNDER PCIS#16041-90000-00869(((Installation of roof-mounted solar PV system, not exceeding a total AC output of 10 kW, in a 1 or 2 family dwelling	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77489	14041-20000-03297	17383 W SUNSET BLVD BUILDING A	90272	11	126B117   642	4416003026	C2-1XL	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	Commercial			02/05/2014 12:00:00 AM			PC Approved	02/05/2014 12:00:00 AM	ADDRESS	34.03917	-118.55529	T24 FOR EXISTING BATHROOM. SCOPE OF WORK IN BUILDING A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77490	14041-10000-10503	2667 N PIRTLE ST	90039	13	147A213    99	5442011015	R2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Elysian Valley Riverside		1872.00	Electrical	Electrical	1 or 2 Family Dwelling			04/22/2014 12:00:00 AM	06/17/2014 12:00:00 AM		Permit Finaled	06/26/2014 12:00:00 AM	ADDRESS	34.09801	-118.24423	PV1, INSTALL 6.5 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 2-STORY HOME INTERCONNECT WITH MAIN SERVICE PANEL.(1)TRANSFORMERLESS INVERTER: SOLAREDGE # SE6000A-US-ZB-U(26)MODULES: CANADIAN SOLAR # CS6P-250PX	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77491	18041-10000-13745	11111 W SANTA MONICA BLVD 22ND FLR	90025	5	129B153   795	4324034016	M1-1-O	West Los Angeles	West Los Angeles	Westwood		2655.20	Electrical	Electrical	Commercial			04/16/2018 12:00:00 AM	04/25/2018 12:00:00 AM		Permit Finaled	07/13/2018 12:00:00 AM	ADDRESS	34.04771	-118.44481	PC FOR INTERIOR RESTROOM REMODEL AND UPGRADE FOR T-24 ENERGY ONLY IN A HIGH RISE.TOTAL AFFECTED AREA 1530 SQ.FT SCOPE INCLUDES NEW LIGHTS, CIRCUITS AND RECPTACLES.b#18016-10000-11126	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77492	16041-10000-40257	600 WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			11/14/2016 12:00:00 AM			PC Approved	11/14/2016 12:00:00 AM	ADDRESS	33.9427	-118.40223	PC FOR T24 ENERGY ONLY. NEW CORRIDORS AND UPGRADED LIGHTING. NEW EXITS SIGNS CONNECTED TO EXISTING CIRCUITS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77493	10041-20000-18855	4500 W WILSHIRE BLVD	90010	10	132B185    45	5090014001	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2127.00	Electrical	Electrical	Commercial			09/22/2010 12:00:00 AM	02/11/2011 12:00:00 AM		Permit Finaled	02/15/2011 12:00:00 AM	ADDRESS	34.06175	-118.32753	replace a/c unit on roof  with loar load 213 A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77494	14041-20000-18185	2005 W SAN FERNANDO ROAD	90065	1	148-5A215  47	5442004010	[Q]M1-1-CDO	East Los Angeles	Northeast Los Angeles	Greater Cypress Park		1852.03	Electrical	Electrical	Commercial			07/07/2014 12:00:00 AM	08/18/2014 12:00:00 AM		Permit Finaled	12/09/2014 12:00:00 AM	ADDRESS	34.10155	-118.23637	PV2INSTALL ROOF MOUNTED PV SYSTEM ON A COMMERCIAL BUILDING.  INTERCONNECTED WITH DWP MSP. SYSTEM SIZE 5KW AND 10KW. (1) FRONIUS USA IG PLUS A 5000 INVERTER(1) FRONIUS USA IG PLUS A 10000 INVERTER	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77495	15041-10000-26563	1470 N TIGERTAIL ROAD	90049	11	141B137    60	4493025001	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			08/14/2015 12:00:00 AM	08/14/2015 12:00:00 AM		Permit Finaled	10/07/2015 12:00:00 AM	ADDRESS	34.08279	-118.4877	PV1, INSTALL NEW  10 KW AC ROOF-MOUNTED SOLAR ARRAY ON SINGLE FAMILY HOME.(38) MODULES AND ONE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77496	10041-20000-10807	10990 W WILSHIRE BLVD SUITE 800	90024	5	132B149   138	4324002***	[Q]C4-2-O	West Los Angeles	Westwood			2655.10	Electrical	Electrical	Commercial			06/08/2010 12:00:00 AM			PC Approved	06/15/2010 12:00:00 AM	ADDRESS	34.0577	-118.44711	Lighting and power in office area. This plan check is for title 24 energy only. Permit obtained for 10 new branch circuits in app# 10041-20000-10812.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77497	15041-10001-43757	850 S HOPE ST	90017	14	127-5A209  28	5144020196	[Q]C4-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			08/16/2016 12:00:00 AM			PC Approved	09/08/2016 12:00:00 AM	ADDRESS	34.04528	-118.25988	changes of approved of set of plans changes noted delta 7. change to load shedules and revised landlord equipment	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77498	19041-10000-40739	14311 W VENTURA BLVD	91423	4	165B153  1093	2265019031	(Q)C2-1VL	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.01	Electrical	Electrical	Commercial			10/08/2019 12:00:00 AM	03/16/2020 12:00:00 AM		Permit Finaled	01/20/2021 12:00:00 AM	ADDRESS	34.15039	-118.44453	FULL PC FOR POWER AND ENERGY FOR A TENANT FINISH FOR GROCERY STORE WITH INDOOR DELI. SCOPE INCLUDES A NEW 2000A AND 1200A DISTRIBUTION BOARD, NEW PANELS, NEW CIRCUITS, AND NEW LIGHTS. TOTAL AFFECTED AREA IS 44,660 SQ. FT. B#19016-10000-32102	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77499	16041-10002-23085	1000 E WASHINGTON BLVD Unit 105	90021	9	121-5A211 373	5131008048	M1-2	South Los Angeles	Southeast Los Angeles	South Central		2260.01	Electrical	Electrical	Commercial			02/16/2017 12:00:00 AM			PC Info Complete	02/16/2017 12:00:00 AM	ADDRESS	34.0256	-118.2533	02/16/16Changes to an approved set of plans. All changes are clouded under delta 3. Changes include adding 3 additional exhaust dryers on the roof layout, revising panel schedules, and load calculations.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77500	13041-10001-32434	654 E VERNON AVE	90291	11	111B145  1229	4239003018	RD1.5-1	West Los Angeles	Venice	Venice		2732.00	Electrical	Electrical	1 or 2 Family Dwelling			11/19/2013 12:00:00 AM			Reviewed by Supervisor	05/01/2014 12:00:00 AM	ADDRESS	33.99767	-118.46818	Expedited RSES plan check per applicant request.(((PV1, Install 4.75 kW DC roof-mounted solar array, interconnect with service panel. Transformerless inverter. Solaredge SE5000A-US. 19 modules TRINA SOLAR TSM-250PA05.18.)))	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77501	15041-20001-39720	16138 W OTSEGO ST	91436	5	171B141   310	2260020003	RA-1	South Valley	Encino - Tarzana	Encino		1397.01	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM			PC Approved	12/05/2015 12:00:00 AM	ADDRESS	34.16287	-118.48501	EXPEDITER PER APPLICANT REQUEST. ((((PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 9.52KWac. (40) AC modules-SUNPOWER SPR-X20-205-BLK	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77502	19041-20000-20075	2222 E WASHINGTON BLVD	90021	14	118-5A217 138	5167005027	M3-1-RIO	Central	Central City North	Downtown Los Angeles		2060.31	Electrical	Electrical	Commercial			05/28/2019 12:00:00 AM	07/03/2019 12:00:00 AM		Permit Finaled	08/16/2019 12:00:00 AM	ADDRESS	34.0188	-118.23256	FULL PLAN CHECK FOR CHANGE OF USE FROM WAREHOUSE TO INDUSTRIAL HYDROPONICS. SCOPE OF WORK INCLUDES A NEW 100A PANEL,T24 INCLUDED. TOTAL SQUARE FOOTAGE = 3034 SFB#18016-10000-40841	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77503	13041-20000-14802	435 S OCCIDENTAL BLVD	90057	1	135A201    48	5155010007	R4-1	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			06/19/2013 12:00:00 AM	10/16/2015 12:00:00 AM		Permit Expired	11/13/2017 12:00:00 AM	ADDRESS	34.06531	-118.28392	RENOVATION OF CHURCH. PLACE OF ASSEMBLY. SCOPE OF WORK INCLUDES CHANGE IN LIGHTING, EXTERIOR AND INTERIOR, AND CHANGE IN DISTRIBUTION PANEL AND CIRCUITS. PLAN CHECK FOR POWER AND ENERGY. TOTAL AREA 22022 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77504	11041-20000-23003	555 W 5TH ST 20th floor	90013	9	130-5A211 114	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.00	Electrical	Electrical	Commercial			10/27/2011 12:00:00 AM	01/09/2012 12:00:00 AM		Permit Finaled	03/27/2012 12:00:00 AM	ADDRESS	34.05016	-118.25369	TI 20th floor energy plan check	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77505	14041-20000-14422	8044 N FAIRCHILD AVE	91306	3	189B109   234	2108012014	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1342.01	Electrical	Electrical	1 or 2 Family Dwelling			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	07/03/2014 12:00:00 AM	ADDRESS	34.21674	-118.58756	pc for pv1, microinverter. using enphase m215. using standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77506	15041-10000-07137	6621 N FALLBROOK AVE	91307	12	180B097   254	2038040014	QC2-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.01	Electrical	Electrical	Commercial			03/11/2015 12:00:00 AM	03/11/2015 12:00:00 AM		Permit Finaled	06/05/2015 12:00:00 AM	ADDRESS	34.19037	-118.62371	New fire alarm system for an exsiting two story building; scope includes (1) fire alarm panel, (4) power supplies, ( 1) annunciator,  and (77) fire alarm devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77507	19041-20000-06676	10535 W MOORPARK ST	91602	4	165B177   311	2424002007	RD1.5-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Greater Toluca Lake		1431.00	Electrical	Electrical	Apartment			02/25/2019 12:00:00 AM	05/31/2019 12:00:00 AM		Issued	05/31/2019 12:00:00 AM	ADDRESS	34.15052	-118.36066	New 5-unit 4-story apartment building with 800A 240/120V 3ph-4w service.  Building permit under 16010-20000-04705.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77508	13041-10000-21151	12652 W VILLAGE LANE bldg #6	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Apartment			08/07/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Finaled	02/05/2015 12:00:00 AM	ADDRESS	33.97757	-118.41475	FIRE ALARM IN A  New 4-story, Type VA construction, 3 unit condo over parking garage. FULLY- SPRINKLER.BUILDING #6	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77509	13041-10000-27370	3411 S COLBERT AVE	90066	11	117B157   371	4249006001	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2716.00	Electrical	Electrical	1 or 2 Family Dwelling			10/02/2013 12:00:00 AM	10/18/2013 12:00:00 AM		Permit Finaled	10/22/2013 12:00:00 AM	ADDRESS	34.01763	-118.43059	PV1. ROOFMOUNTED SOLAR ARRAY. 1 STORY HOUSE.  5.7KW DCTRANSFORMERLESS AND UNGROUNDED SYSTEM.(22) LG LG260S1K-A3 260W SOLAR MODULES(22) SOLAREDGE OPTOMIZERS OP300-MV(1) SOLAREDGE SE6000-US IVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77510	19041-10000-47530	7915 N LINDLEY AVE	91335	12	189B125   476	2102014057	RA-1	South Valley	Reseda - West Van Nuys	Reseda		1314.00	Electrical	Electrical	Commercial			11/19/2019 12:00:00 AM	11/19/2019 12:00:00 AM		Permit Finaled	12/07/2019 12:00:00 AM	ADDRESS	34.21435	-118.5275	REPLACE FLUORESCENT TROFFERS WITH NEW LED RETROFIT KITS - 1ST FLOOR (INDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77511	16041-30000-45258	230 N CARMELINA AVE	90049	11	132B141    35	4405004008	RE20-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.03	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2016 12:00:00 AM			PC Approved	01/26/2017 12:00:00 AM	ADDRESS	34.06138	-118.48441	Plan check for power.  New single family dwelling with 600 amp service and 25 kW backup generator.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77512	15041-10000-35973	1804 1/2 S 4TH AVE	90019	10	126B189   774	5072029018	RD2-1-O	South Los Angeles	West Adams - Baldwin Hills - Leimert	Untd Nghbrhds of Hstrc Arlington Hghts/W Adams/Jef		2181.20	Electrical	Electrical	Apartment			10/27/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	04/07/2016 12:00:00 AM	PIN	34.04070335	-118.32098229	INSTALLATION OF ROOF-MOUNTED 3.445KW PV SYSTEM	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77513	17041-10000-04237	1640 S SEPULVEDA BLVD #210	90025	5	129B153   700	4324033024	[Q]C2-1L-O	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Commercial			02/09/2017 12:00:00 AM			PC Approved	02/09/2017 12:00:00 AM	ADDRESS	34.04838	-118.44468	Plan check for Title 24 only in existing space T.I. in office area. Total area: 2,321 sq ft	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77514	15041-10000-27032	2235 S MANSFIELD AVE	90016	10	123B181   160	5062014023	RD2-1	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2185.00	Electrical	Electrical	1 or 2 Family Dwelling			08/18/2015 12:00:00 AM	08/18/2015 12:00:00 AM		Permit Finaled	01/08/2016 12:00:00 AM	ADDRESS	34.03662	-118.3504	ROOF MOUNTED SOLAR SYSTEM, 22 MODULES AND 1 INVERTER 6KW. (22) KYOCERA #KU2656ZPA (1) ABB #PVI-6000-OUTD-US-Z-A	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77515	14041-10000-14381	12852 W RUNWAY ROAD	90094	11	102B161  1221	4211033040	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			05/30/2014 12:00:00 AM	05/30/2014 12:00:00 AM		Permit Finaled	02/11/2015 12:00:00 AM	ADDRESS	33.97543	-118.41892	NEW FIRE ALARM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77516	14041-20001-21078	6400 N OWENSMOUTH AVE A-C	91367	3	180B105    64	2146005027	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			04/07/2015 12:00:00 AM			PC Approved	04/07/2015 12:00:00 AM	ADDRESS	34.18653	-118.6013	Changes to approved set.  Addition of integral current limiters into each seperate track light.  Updates to Title-24 forms.*****Previous Work Description*****Tenant improvement of existing commercial building.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77517	18041-10000-39560	601 S FIGUEROA ST 2130	90017	14	130-5A209 143	5144007044	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			10/16/2018 12:00:00 AM			Corrections Issued	10/16/2018 12:00:00 AM	ADDRESS	34.05076	-118.25881	Plan check only. PC  FOR INTERIOR OFFICE TI IN A HIGH RISE FOR T-24 ENERGY ONLY. SCOPE INCLUDES NEW PANEL, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 3005 SQ.FT B#18016-10000-31431	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77518	12041-10001-19627	3237 W TERZILLA PL PV-1	90065	14	159A215    60	5678027010	R1-1-CDO	East Los Angeles	Northeast Los Angeles	Glassell Park	YES	1861.00	Electrical	Electrical	1 or 2 Family Dwelling			08/31/2012 12:00:00 AM			PC Approved	09/13/2012 12:00:00 AM	ADDRESS	34.13123	-118.23417	PLAN CHECK FOR INSTALLATION OF 4.3KW AC PHOTOVOLTAIC SYSTEM (ENPHASE M215 MICROINVERTERS). PREVIOUS APPLICATION WAS CENTRAL INVERTERpermit was obtained on separate appication.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77519	19041-10000-44398	3785 W WILSHIRE BLVD 104A-C	90010	10	132B193  1214	5503030908	C4-2	Central	Wilshire	Wilshire Center-Koreatown		2118.02	Electrical	Electrical	Commercial			10/30/2019 12:00:00 AM	11/01/2019 12:00:00 AM		Permit Finaled	01/29/2020 12:00:00 AM	ADDRESS	34.06187	-118.30858	T-24 PLAN CHECK FOR A TI TO EXISTING SPACE. SCOPE INCLUDES NEW EQUIPMENT, LIGHTING, RECEPTACLES AND CONTROLS. NEW CONNECTED LOAD IS LESS THAN 400A. TOTAL AFFECTED AREA IS 2690 SQ.FTB#19016-10000-32370	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77520	17041-10000-46155	1601 N VINE ST	90028	13	148-5A187 301	5546009906	(T)(Q)C4-2-SN	Central	Hollywood	Central Hollywood		1907.00	Electrical	Electrical	Commercial			12/22/2017 12:00:00 AM	01/16/2018 12:00:00 AM		Issued	01/16/2018 12:00:00 AM	ADDRESS	34.09996	-118.32693	Plan check for an addition of (219) devices and (9) power supplies to an existing fire alarm system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77521	17041-10000-42568	7354 N WOODMAN AVE	91405	2	186B157   367	2328002094	R3-1	South Valley	Van Nuys - North Sherman Oaks			1271.03	Electrical	Electrical	Public Safety Only			11/27/2017 12:00:00 AM	11/27/2017 12:00:00 AM		Permit Finaled	06/12/2019 12:00:00 AM	ADDRESS	34.20466	-118.43108	NEW FIRE WARNING SYSTEM FOR 86 UNITS APARTMENT BUILDING	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77522	16041-20000-12661	2104 W COLORADO BLVD Suite A	90041	14	162A223   121	5686003018	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1814.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM			PC Approved	04/12/2016 12:00:00 AM	ADDRESS	34.13897	-118.21223	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,020 sq. ft.Note: Building application has been generated under 16016-20000-07953	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77523	15041-20000-38548	11945 N CAMEO PL	91344	12	216B133   464	2606017030	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			11/16/2015 12:00:00 AM	11/16/2015 12:00:00 AM		Permit Finaled	05/20/2016 12:00:00 AM	ADDRESS	34.2868	-118.50677	PV system.Install a roof mounted solar array on a SFD. Interconnect with a 200A MSP.System size: 6kW. Ungrounded system. (27) 265W pv modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77524	19041-20000-03857	17171 W ARMSTEAD ST	91344	12	213B133   181	2607015054	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.42	Electrical	Electrical	1 or 2 Family Dwelling			01/31/2019 12:00:00 AM	02/06/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.28288	-118.50729	9.8 kWh energy storage system and critical load panel added to an existing PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77525	19041-10000-48069	4601 E YORK BLVD	90041	14	156A221    38	5474013025	[Q]C4-1XL	East Los Angeles	Northeast Los Angeles	Eagle Rock		1834.02	Electrical	Electrical	Commercial			11/21/2019 12:00:00 AM	11/21/2019 12:00:00 AM		Issued	11/21/2019 12:00:00 AM	ADDRESS	34.12332	-118.2158	REMOVE HID FIXTURES AND REPLACE WITH NEW LED FIXTURES- T/24 ONLY (OUTDOOR)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77526	17041-30000-17256	832 S ST ANDREWS PL	90005	4	132B193   696	5093002017	R4-1	Central	Wilshire	Greater Wilshire		2126.20	Electrical	Electrical	Apartment			05/23/2017 12:00:00 AM	01/15/2019 12:00:00 AM		Issued	01/15/2019 12:00:00 AM	ADDRESS	34.05709	-118.31103	Full plan check for a new 5 story 16 units appartment with a 1200-Amp service 120/240 3-phase 4-wires. Total area: 16,476 sq ft. B#16010-10000-05702	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77527	19041-10001-11490	1147 S HOPE ST	90015	14	126A207    20	5138014003	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			03/29/2019 12:00:00 AM			PC Approved	07/17/2019 12:00:00 AM	ADDRESS	34.04129	-118.2642	**fee expedited per applicant**New PV2 Rooftop solar system 24 kW AC. Install (99) modules, (2) inverters at 12kW AC each, (1) 100A combiner panel. System connect to (E) 400A MSP.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77528	18041-10000-25300	8502 W SHERWOOD DR	90069	5	141B173   300	4337003063	C4-1VL	Central	Hollywood	Mid City West		1944.02	Electrical	Electrical	Commercial			07/06/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Permit Finaled	02/15/2019 12:00:00 AM	ADDRESS	34.08477	-118.37667	PC FOR TENANT IMPROVEMENT FOR RETAIL STORE FOR TITLE 24 ENERGY ONLY. SCOPE INCLUDES NEW LIGHTS, CIRCUITS AND EQUIPMENT. TOTAL AFFECTED AREA 4959 SQ.FT (INDOOR AND OUTDOOR).B# 18016-10000-21609	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77529	16041-20000-18452	8206 S HOOVER ST	90044	8	099B201  1287	6032022028	C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	1 or 2 Family Dwelling			05/25/2016 12:00:00 AM	06/02/2016 12:00:00 AM		Permit Finaled	07/08/2016 12:00:00 AM	ADDRESS	33.96404	-118.28691	Plan check for PV roof mounted system. system size: 3.8kW with 13 modules and 1 inverter(3.8kW)	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77530	17041-20001-22783	14620 W RUNNYMEDE ST	91405	6	186B149   461	2218005006	R1-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1272.20	Electrical	Electrical	1 or 2 Family Dwelling			07/07/2017 12:00:00 AM			PC Approved	08/03/2017 12:00:00 AM	ADDRESS	34.2057	-118.45194	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 10.4 kWac and consists of (2) inverters, (42) modules, and (1) load center.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77531	16041-10000-11593	647 W 32ND ST	90007	9	120A203    38	5123010030	R3-1-O	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2247.00	Electrical	Electrical	Commercial			04/04/2016 12:00:00 AM	04/04/2016 12:00:00 AM		Permit Finaled	08/23/2016 12:00:00 AM	ADDRESS	34.02428	-118.28036	Installation of a new fire alarm system in a digital arts studio. (1) New FA panel, (1) Communicatoin panel, (16) devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77532	19041-20001-51705	595 S MAPLETON DR	90024	5	138B157    76	4359013016	RE40-1	West Los Angeles	Westwood	Westwood		2651.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2019 12:00:00 AM			PC Approved	01/30/2020 12:00:00 AM	ADDRESS	34.07362	-118.42902	EXPEDITEDPV1. INSTALL 22.57 KW DC ROOFMOUNTED PV SYSTEM WITH (61) AC MODULES CONNECTED TO 600 AMP (E) SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77533	18041-20001-03963	20544 W DEFOREST ST	91364	3	169-5A111  39	2166023016	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			02/02/2018 12:00:00 AM			PC Approved	02/13/2018 12:00:00 AM	ADDRESS	34.16008	-118.58091	INSTALL A 10.8KW PV SYSTEM ON A SINGLE FAMILY HOME USING 34 AC MODULES.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77534	15041-10001-19186	12435 W OLYMPIC BLVD	90025	11	123B145   336	4259019005	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			09/11/2015 12:00:00 AM			PC Approved	09/11/2015 12:00:00 AM	PIN	34.03188711	-118.45923154	(9/11/2015)CHANGES TO AN APPROVED SET OF PLANS.  CHANGES NOTED DELTA 5.  THE CHANGES INCLUDE REVISIONS TO THE ENERGY CALCS AND LIGHTING FIXTURE TYPES.  THIS IS PLAN CHECK ONLY.Title 24 plan check only.  Total area = 13,023 sq. ft.  T.I. to existing commercial lowrise office space.  New lighting and recepticles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77535	13041-20001-30281	314 N BARRINGTON AVE PV-1	90049	11	135B141   121	4429023025	RE11-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2623.02	Electrical	Electrical	1 or 2 Family Dwelling			10/29/2013 12:00:00 AM			PC Approved	05/09/2014 12:00:00 AM	ADDRESS	34.06895	-118.47258	PV1 SINGLE FAMILY DWELLING. TOTAL SYSTEM SIZE 16 KW AC USING 49 MODULES, TRANSFORMERLESS INVERTERS NONSTANDARD PLAN. NEW SUBMITTAL FOR COMPLETE CHANGE IN SYSTEM	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77536	17041-20000-12098	20340 W ABERDEEN LANE	91326	12	213B113   463	2701094020	[T]RE-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			04/13/2017 12:00:00 AM	04/13/2017 12:00:00 AM		Permit Finaled	03/30/2022 12:00:00 AM	ADDRESS	34.28303	-118.57806	PV1.  Install 6.72 kW roof mounted grid tied PV system.  (21) AC modules.  Standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77537	13041-20000-24752	12660 W RIVERSIDE DR 225, 310 &-320	91604	4	168B161   467	2357033017	(Q)C1-1VL	South Valley	Van Nuys - North Sherman Oaks			1247.00	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	09/10/2013 12:00:00 AM		Permit Finaled	10/25/2013 12:00:00 AM	PIN	34.15724389	-118.40930375	Relocate existing outlets only to relocate an existing medical exam room.  No Equipment or Lighting is being relocated or installed.  Building is NOT STATE LICENSED per the applicant, NOT CHECKED FOR OSHPD3.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77538	16041-10000-10054	2108-2110 W SUNSET BLVD	90026	13	139-5A207 106	5402035002	[Q]C2-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian		1957.10	Electrical	Electrical	Commercial			03/22/2016 12:00:00 AM	10/19/2016 12:00:00 AM		Permit Finaled	05/25/2017 12:00:00 AM	PIN	34.07718395	-118.26405818	CREATING SHELL SPACE FOR FUTURE RESTAURANT. PC FOR T24 ENERGY ONLY. NEW LIGHITNG.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77539	17041-10001-27626	3201 N LACY ST	90031	1	142-5A221 279	5205002902	UI(CA)	East Los Angeles	Northeast Los Angeles	Lincoln Heights		1990.00	Electrical	Electrical	Commercial			12/19/2017 12:00:00 AM			PC Approved	12/19/2017 12:00:00 AM	ADDRESS	34.08349	-118.21854	PC FOR REVISIONS TO APPROVED SET DUE TO FIELD CHANGES. ALL CHNGES MARKED UNDER DELTA 2. SCOPE INCLUDES UPDATING LOAD SCHEDULES, UPGRADING PANELS AND BREAKERS. ADDITION OF FLEX CONDUIT. THIS IS PLAN CHECK ONLY!PERMIT FEES UNDER MASTER. SCOPE INCLUDES TEMPORARY POWER FOR PORTABLE BUILDINGS ONLY. NEW SUGGESTED TEMP POWER RATED AT 800A 120/208 V.  APPLICANT NOTED THAT THE BUILDINGS ARE PRE FABRICATED AND  STATE APPROVED.( THE APPLICATION 13041-10000-34763 HAS BEEN EXPIRED WITH THE SAME SCOPE FOR THIS BUILDING)BUILDING PERMIT # 13014-10000-04943.  RENOVATION/REMODEL OF (E) ANIMAL CARE FACILITY  ABOUT 5000 SQ ADDITION; NEW PARKING DESIGN	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77540	12041-10001-12464	735 S FIGUEROA ST SPACE #-123	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			09/19/2012 12:00:00 AM			PC Approved	09/19/2012 12:00:00 AM	ADDRESS	34.04878	-118.26079	REVISION TO APPROVED PLANS ON EMERGENCY LIGHTINGAND EXIT SIGN. REVISE FROM BATTERY BACK UP TO EMERGENCY GENERATOR SUPPLIED.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77541	11041-10000-12765	201 W WORLD WAY WEST	90045	11	090B161    66	4129026903	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			06/27/2011 12:00:00 AM			Corrections Issued	07/03/2011 12:00:00 AM	PIN	33.94386821	-118.41794839	Replacement of 4 elevator unit in them Bldg at LAX.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77542	15041-20001-07737	585 E VENICE BLVD	90291	11	108B145  1530	4241037014	M1-1-O	West Los Angeles	Venice	Venice		2736.00	Electrical	Electrical	Commercial			02/24/2016 12:00:00 AM			PC Approved	02/24/2016 12:00:00 AM	ADDRESS	33.98974	-118.4619	02/24/2016 Changes to an approved set of plans. Plan check is for Delta 6 only. Changes have been made to Panel P1 and the lighting floor plan. Lighting changes have been reflected onto the Title 24 compliance forms.*****Previous Work Description*****PC FOR POWR AND ENERGY. TENANT IMPROVEMENT OF (E) RETAIL SPACE(FOOD MRKET). UPGRADE SERVICE TO 1000 A. 6 SUBPANEL. TOTAL AREA 10200 SQ FT. THE PLAN DOESN'T HAVE SIGNATURE, SUBMITAL PER FRANCIS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77543	16041-10000-27696	6600 N TOPANGA CANYON BLVD #2068	91303	3	180B101   822	2139004044	WC-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1351.14	Electrical	Electrical	Commercial			08/04/2016 12:00:00 AM	11/09/2016 12:00:00 AM		Permit Finaled	12/09/2016 12:00:00 AM	ADDRESS	34.19008	-118.60565	T-24, PC for energy only. Tenant Improvement to an existing retail space. Scope includes new lights, and receptacles. Total affected area is 463 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77544	15041-20000-06576	24550 W GARDENSTONE LANE	91307	12	183B085    66	2031006071	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1352.03	Electrical	Electrical	1 or 2 Family Dwelling			03/05/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Expired	04/19/2017 12:00:00 AM	ADDRESS	34.20021	-118.65972	PV1Install a roof-mounted solar array on a SFD. Interconnect with a 200A MSP, derate main to 150A.System size: 12kW (6+6). Ungrounded system. (51) 260W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77545	17041-20000-07662	446 W 39TH ST	90731	15	006B201    63	7467018035	RD2-1XL	Harbor	San Pedro	Coastal San Pedro		2976.01	Electrical	Electrical	Apartment			03/09/2017 12:00:00 AM			PC Approved	03/09/2017 12:00:00 AM	ADDRESS	33.70886	-118.28658	Plan check for energy only. New lighting for outdoor residential parking lot. 8,085sqft. (new EVSE not plan checked, but include in permit)	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77546	17041-10002-45037	18318 W SHERMAN WAY	91335	3	183B125   203	2125003017	[Q]C2-1D-CDO	South Valley	Reseda - West Van Nuys	Reseda		1323.00	Electrical	Electrical	Commercial			03/05/2018 12:00:00 AM			PC Approved	03/05/2018 12:00:00 AM	ADDRESS	34.20096	-118.53236	Changes to an approved set of plans, Note chanes on delta 2. Changes include the change of fixtures and field reflection. _______PC for T24 only for retail space with office spaces. Installing new lights, receptacles and equipment. Total area is 5089sqft. B# 17016-10000-27695.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77547	17041-20002-38690	10948 N OSO AVE	91311	7	210B113   138	2707031008	(Q)RD3-1	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2018 12:00:00 AM			PC Approved	04/05/2018 12:00:00 AM	ADDRESS	34.26913	-118.57623	PC for changes to approved set. Downsizing feeder supplying 200A load center to 2/0 per 310.15(B)(17). Inspector to check that PV and ESS breakers are connected to opposite end of busbar from main breaker.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77548	13041-10000-36027	13606 W MONTAGUE ST	91331	6	195B157   105	2625037034	R1-1	North Valley	Arleta - Pacoima	Arleta		1198.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM	02/11/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.23466	-118.42879	PV1, Install 5.75 kW DC roof-mounted solar array for a two story house, interconnect with service panel. (1)Transformerless inverter(s): Solaredge SE 5000A-US. (23) modules Trina Solar TSM-250PA05.18.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77549	17041-10000-41102	555 W 5TH ST Suite 3725	90013	14	130-5A211 161	5149029013	C2-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/14/2017 12:00:00 AM	11/20/2017 12:00:00 AM		Permit Finaled	12/15/2017 12:00:00 AM	ADDRESS	34.05016	-118.25369	PC FOR TI on the 13th floor office space to create separate suite (IN A HIGH RISE) FOR TITLE 24 ENERGY ONLY!SCOPE INCLUDES NEW CIRCUITS LIGHTS AND RECEPTACLES. TOTAL 2827 SQ. FTB#17016-10000-19311	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77550	16041-20000-01268	4578 N ENCINO AVE	91316	5	168B129   718	2290022021	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			01/13/2016 12:00:00 AM	03/25/2016 12:00:00 AM		Permit Finaled	09/07/2017 12:00:00 AM	ADDRESS	34.15314	-118.51343	PV1. Install roof mounted PV system sized 7.6 kW. Interconnected with main service panel.(33) 275W Modules(33) 300W Power Optimizers(1) Solar Edge SE7600 Inverter	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77551	12041-20000-13886	1655 N CRESCENT HEIGHTS BLVD	90069	5	148-5A175 260	5556029011	RE9-1	Central	Hollywood	Bel Air - Beverly Crest	YES	1942.00	Electrical	Electrical	1 or 2 Family Dwelling			06/15/2012 12:00:00 AM	09/06/2012 12:00:00 AM		Permit Finaled	09/18/2012 12:00:00 AM	ADDRESS	34.10097	-118.36867	Roof mounted P.V. system (13.6K dc)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77552	13041-10000-16399	750 S LAMAR ST INBOUND-CANOPY	90031	14	133-5A219   5	5410002818	[Q]M3-1	East Los Angeles	Boyle Heights	Lincoln Heights		2035.00	Electrical	Electrical	Commercial			06/21/2013 12:00:00 AM	12/23/2014 12:00:00 AM		Permit Expired	01/17/2017 12:00:00 AM	ADDRESS	34.06186	-118.22511	RAILYARD. PLAN CHECK FOR POWER AND ENERGY. 10 BUILDINGS TO BE SUBMITTED WITH SEPERATE APPLICATION NUMBERS. ONE SET OF PLANS MAY BE SUBMITTED. THIS APPLICATION IS FOR THE (3a) INBOUND CANOPY.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77553	17041-20000-41832	15760 W VENTURA BLVD 5th Floor-Corridors	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			11/17/2017 12:00:00 AM	11/17/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.1552	-118.47684	Plan check for Title 24 only. Project site is the 5th floor corridors of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,570 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77554	18041-10000-20349	1607 E PLEASANT AVE # 1	90033	14	129A221    80	5174024026	RD1.5-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2035.00	Electrical	Electrical	Commercial			06/01/2018 12:00:00 AM			Verifications in Progress	07/17/2018 12:00:00 AM	ADDRESS	34.04838	-118.22052	VOID PER APPLICANT, JOB APPROVED UNDER 1605 E. PLEASANT. 1 OF 2*****PC FOR  A NEW ROOFTOP SOLAR SYSTEM IN A COMMERCIAL APPARTMENT COMPLEX. CONISIT OF 14 MODULES(QPEAK-G4/SC305) AND A CENTRAL INVERTER (UNO-DM-3.3) . SYSTEM SIZE IS 3.3KWac AND 4.27KWdc.SCOPE INCLUDES NEW LOAD CENTER (125A).	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77555	17041-10001-16731	2735 N LA CUESTA DR	90046	4	156B177   679	5570002001	R1-1	South Valley	Hollywood	Hollywood Hills West	YES	1941.01	Electrical	Electrical	1 or 2 Family Dwelling			05/18/2017 12:00:00 AM			Reviewed by Supervisor	05/31/2017 12:00:00 AM	ADDRESS	34.12104	-118.35657	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling with battery back up system.  Two new 5.2 kWac inverters connected to 125 amp load center.  New AC coupled 5.8 kVA / 13 kWH battery.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77556	18041-20000-15689	16331 W BERMUDA ST	91344	12	207B137   109	2680020028	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1111.00	Electrical	Electrical	1 or 2 Family Dwelling			04/27/2018 12:00:00 AM			Reviewed by Supervisor	06/04/2018 12:00:00 AM	ADDRESS	34.26719	-118.48784	PV1.  Installation of 8.56 kW DC grid tied PV system mounted on new carport and patio cover. (29) modules with 7.6 kW rated string inverter.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77557	14041-10002-14918	2239 W QUEENSBOROUGH LANE	90049	5	150B141    86	4377046004	RE15-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM	08/06/2014 12:00:00 AM		Permit Finaled	08/15/2014 12:00:00 AM	ADDRESS	34.10938	-118.47778	(((8/6/2014 Zero fee because of senate bill 2221.  Supl. app. for addition of 3 solar PV modules to previously approved existing system.  Total inverter output power = 6.8 kWac)))PV1, INSTALL 7.75 KW DC ROOF-MOUNTED SOLAR ARRAY ON A TWO-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL. TRANSFORMERLESS INVERTER. WITH OPTIMIZER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77558	14041-10001-22916	2160 N LAKE SHORE AVE	90039	13	145-5A211 287	5420008002	R1-1VL	East Los Angeles	Silver Lake - Echo Park - Elysian Valley	Greater Echo Park Elysian	YES	1974.10	Electrical	Electrical	Apartment			08/22/2014 12:00:00 AM			Reviewed by Supervisor	09/10/2014 12:00:00 AM	ADDRESS	34.0924	-118.25255	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 2.5 ROOF-MOUNTED SOLAR ARRAY ON 2-STORY HOUSE, INTERCONNECT WITH MAIN SERVICE PANEL.(10) MODULES: CANADIAN SOLAR CS6-250PX(1) INVERTER: SOLAREDGE SE3000A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77559	19041-10000-33703	2377 N JUPITER DR	90046	4	153B177   484	5569008012	RE15-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2019 12:00:00 AM	09/11/2019 12:00:00 AM		Issued	09/11/2019 12:00:00 AM	ADDRESS	34.11254	-118.36361	PV1 NEW ROOFTOP MOUNTED SYSTEM, SYSTEM SIZE IS 13.2KWdc/12.6KWac. SCOPE OF WORK IS 40 MODULES (PANASONIC VBHN330SA17) WITH MICRO INVERTERS (ENPHASE IQ7X-960US) LEADING TO A COMBINER PANEL. NOTE: MAIN PANEL UPGRADE TO BE SEPRATELY PERMITTED	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77560	15041-20003-13941	600 WORLD WAY Term 6	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			12/02/2015 12:00:00 AM			PC Approved	12/02/2015 12:00:00 AM	ADDRESS	33.9427	-118.40223	Changes to approved set, 2nd change on fixture type and removed the show window.(((((((Changes to approved set.  Change of fixture type. ))))))(((first tenant in commercial spacefull plan chk)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77561	12041-10001-06926	5533 W HOLLYWOOD BLVD	90028	4	148-5A193 133	5544005003	[Q]R5-2	Central	Hollywood	Hollywood United		1903.01	Electrical	Electrical	Public Safety Only			05/21/2012 12:00:00 AM	05/21/2012 12:00:00 AM		Permit Finaled	01/19/2016 12:00:00 AM	ADDRESS	34.10188	-118.31038	UPON THE REQUEST OF THE ELECTRICAL INSPECTOR, PLAN CHECK FOR NEW FIRE WARNING SYSTEM- TOTAL  FA DEVICES IS 296.; PERMIT WILL BE FOR ADDITIONAL 162 FA DEVICES AND FA PANEL. EACH FLOOR IS DIVIDED INTO 2 ZONESExisting fire alarm system and panel to an existing 160, 5-story, apartment complex.  134 new devices only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77562	16041-20000-31971	5200 S CENTRAL AVE	90011	9	108B209    95	5104003034	RD1.5-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2287.10	Electrical	Electrical	Commercial			09/08/2016 12:00:00 AM	06/05/2017 12:00:00 AM		Permit Finaled	07/17/2018 12:00:00 AM	ADDRESS	33.99574	-118.25623	Plan check for the ground-mounted portion of a PV2 roof-mounted & ground-mounted PV system. PV system is part of the LADWP feed in tariff (FIT) program. Ground-mounted portion is 267 kWac and consists of (6) 36 kWac inverters, (1) 28 kWac inverter, (1) 23 kWac inverter,  (954) modules, and (3) load centers. Total system size is 323 kWac.Note: Roof-mounted portion of the PV2 PV system can be found under application number 16041-20000-31964	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77563	14041-10000-04293	11160 N BALBOA BLVD	91344	12	210B133   327	2682021032	C2-1VL, C4-1VL, P-1VL	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	Commercial			02/14/2014 12:00:00 AM	03/19/2014 12:00:00 AM		Permit Finaled	04/24/2014 12:00:00 AM	ADDRESS	34.2736	-118.50196	Small commercial TI to existing Chase Bank.  New private offices being constructed, plan check for Title 24 for changes to lighting system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77564	11041-10000-21843	800 W WORLD WAY Terminal 8-8E	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		2780.00	Electrical	Electrical	Commercial			10/12/2011 12:00:00 AM	03/05/2012 12:00:00 AM		Permit Finaled	07/09/2012 12:00:00 AM	PIN	33.94153561	-118.3984113	Remodel for Carl's Junior at terminal 8 space 8E.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77565	11041-10000-23369	8221 N WOODLAKE AVE	91304	3	192B093   498	2020019006	RE11-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.01	Electrical	Electrical	1 or 2 Family Dwelling			11/01/2011 12:00:00 AM	01/26/2012 12:00:00 AM		Permit Finaled	02/01/2012 12:00:00 AM	ADDRESS	34.21846	-118.63246	Photovolatiac system for a SFR.  11KVA Rooftop System.  PLAN CHECK ONLY, existing permit is on a seperate application.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77566	16041-20001-21136	200 S GRAND AVE	90012	14	132A211    50	5149010***	R5-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			11/21/2016 12:00:00 AM			PC Approved	11/21/2016 12:00:00 AM	ADDRESS	34.05408	-118.24993	Revisions to approved set.  Changes to lighting design to accommodate new Starbucks tenant. PLANCHECK FOR T24 ENERGY. COLBURN SCHOOL CAFETERIA. 451 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77567	10041-10000-05427	1101 E 5TH ST	90013	9	127-5A215 401	5163025009	M3-1	Central	Central City North	Historic Cultural		2060.50	Electrical	Electrical	Commercial			03/25/2010 12:00:00 AM	03/26/2010 12:00:00 AM		Permit Expired	12/09/2015 12:00:00 AM	ADDRESS	34.04168	-118.23709	REVISIONS TO EXISTING WARE HOUSEPLAN CHK IS FOR TITLE 24 AND 1 EA EMERGENCY CKT	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77568	17041-20000-05840	8026 N LANKERSHIM BLVD	91605	6	189B169   164	2311005018	M1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	North Hollywood Northeast		1219.00	Electrical	Electrical	Commercial			02/23/2017 12:00:00 AM	02/23/2017 12:00:00 AM		Permit Finaled	10/24/2017 12:00:00 AM	ADDRESS	34.21642	-118.38758	PLANCHECK FOR POWER ONLY. INSTALLATION OF PAINT SPRAY BOOTH. COL-MET ENGINEERED FINISHING SOLUTIONS EZ PIT DOWNDRAFT SPRAYBOOTH.  BUILDING PLANCHECK # : 17016-20000-04062	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77569	19041-20002-06858	8700 S PERSHING DR PV2	90293	11	096B153  1184	4118005159	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2766.03	Electrical	Electrical	Apartment			07/23/2019 12:00:00 AM	07/23/2019 12:00:00 AM		Issued	07/23/2019 12:00:00 AM	ADDRESS	33.95471	-118.44097	Revisions to approved set of plans and change of scope of work.  Approval for clouded changes delta-1 only.  Work description change:  PV2.  Install 76.65 kW DC / 70.03 kW AC roof mounted grid tied PV system.  (210) modules with (2) 33.3 kW rated inverters.  Interconnecting with MSA-2.(((PV2.  Install 122.64 kW DC / 112.06 kW AC roof mounted grid tied PV system.  (336) modules with (4) 30 kW rated string inverter.  Interconnecting with MSA-2.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77570	16041-20000-40318	1408 N POINSETTIA PL Unit #B	90046	4	147B181   927	5548019036	R3-1	Central	Hollywood	Hollywood Hills West		1899.02	Electrical	Electrical	1 or 2 Family Dwelling			11/15/2016 12:00:00 AM			Reviewed by Supervisor	01/05/2017 12:00:00 AM	ADDRESS	34.09607	-118.3481	Plan check for power only. New SFD - unit B - part of 5 attached SFDs fed from (N) common 600A service.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77571	14041-20000-21481	137 N DOHENY DR 1-5	90048	5	138B169   227	4335006027	[Q]R4-1-O	Central	Wilshire	Mid City West		2149.01	Electrical	Electrical	Apartment			08/08/2014 12:00:00 AM	08/25/2016 12:00:00 AM		Permit Finaled	08/08/2023 12:00:00 AM	ADDRESS	34.07637	-118.39	Plan check for power and energy. New 5-story, 5 unit apartment plus 2-subterranean parking levels. Fire alarm variance filed. Fee calculation provided by applicant, verify.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77572	15041-20000-33986	10948 N HILLHAVEN AVE	91042	7	210B197   416	2553018013	RE9-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1011.22	Electrical	Electrical	1 or 2 Family Dwelling			10/13/2015 12:00:00 AM	10/27/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	ADDRESS	34.26839	-118.28803	PV1, Install (1) inverter and  (16) new roof mounted PV modules and connect to (E)(30) modules, system has optimizer for the entire system. New system total 13.8 kW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77573	18041-20002-20184	5327 N DONNA AVE	91356	3	171B121   147	2163022027	RA-1	South Valley	Encino - Tarzana	Tarzana		1394.02	Electrical	Electrical	1 or 2 Family Dwelling			05/31/2018 12:00:00 AM			PC Approved	06/12/2018 12:00:00 AM	ADDRESS	34.16783	-118.54858	Plan check for a PV1 roof-mounted PV system. System size is 10.4KVA consisting of (2) inverter - solivia 5.2TL, (38) modules, and (1) load centers. with (2) battery backup system 13.5kwh each	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77574	15041-10000-31696	2101 E PACIFIC COAST HWY	90744	15	036B213     5	7315017005	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Special Equipment			09/24/2015 12:00:00 AM	12/08/2015 12:00:00 AM		Permit Finaled	03/28/2017 12:00:00 AM	ADDRESS	33.79173	-118.23549	INSTALLING A 1250 KVA, 15KV/480V 3 PHASE POWER DISTRIBUTION TRANSFORMER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77575	14041-20003-13379	2768 W FYLER PL	90065	14	159A219    69	5684019020	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1813.00	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2014 12:00:00 AM			PC Approved	07/16/2014 12:00:00 AM	ADDRESS	34.13152	-118.22676	Total fee is 0.00 base on Senate bill 1222 from 2012Plan check only for relocating roof top  junction box;  moving (2) inverters and the load center into the garage ,  additional PV disconnect also added inside the garage. (((7.5KW PV1 roof-mounted system with (2) Solaredge transformerless inverter model #  SE3000A-US, (30) Renesola modules model # JC250M-24/BB and a Solaredge Power Optimizer model # P300.)))	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77576	19041-20000-00963	14605 W DEL PLAYA ST LOT 2	91402	6	201B149   361	2650019024	(T)(Q)RD2-1, (T)(Q)RS-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1193.10	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	07/23/2019 12:00:00 AM	ADDRESS	34.24795	-118.45054	Plan check for PV roof mounted system, system size: 3.02kW with 9 AC Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77577	15041-20000-20695	700 S FLOWER ST SUITE 2990	90017	14	129A209   259	5144010***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/30/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Permit Finaled	08/04/2015 12:00:00 AM	ADDRESS	34.04835	-118.25882	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO OFFICES ON 29TH FLOOR. SUITE 2990. SQFT: 3189  , EMERGENCY LIGHTING.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77578	15041-10000-12007	100 WORLD WAY TERM 4	90045	11	093B165   166	4117034900	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			04/22/2015 12:00:00 AM	04/22/2015 12:00:00 AM		Permit Finaled	07/21/2015 12:00:00 AM	ADDRESS	33.94572	-118.40095	at lax, installation of illuminated  numeral signs to identify the terminalsplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77579	18041-20001-38435	5922 1/2 W BARTON AVE	90038	13	144B189  1076	5534027036	R3-1XL	Central	Hollywood	Hollywood Studio District		1918.10	Electrical	Electrical	Commercial			10/09/2018 12:00:00 AM			PC Approved	10/15/2018 12:00:00 AM	ADDRESS	34.08778	-118.32315	expeditepv2install roof mounted pv system sized 2KW AC interconnected with msp.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77580	16041-20000-23271	8892 W COLLINGWOOD DR	90069	4	147B169   849	5560038003	RE15-1-H	Central	Hollywood	Bel Air - Beverly Crest	YES	1943.00	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2016 12:00:00 AM	07/14/2016 12:00:00 AM		Permit Finaled	09/22/2016 12:00:00 AM	ADDRESS	34.09603	-118.385	$0 permit fee per State Senate Bill SB 1222Plan check for a PV1 roof-mounted PV system. System size is 22.8 kWac and consists of (3) inverters, (61) modules, and (1) load center.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77581	19041-10000-34888	5048-5052 W VENICE BLVD	90019	10	126B181   116	5067002056	C2-1VL-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert	Mid City		2183.00	Electrical	Electrical	Commercial			09/04/2019 12:00:00 AM			Reviewed by Supervisor	09/11/2019 12:00:00 AM	ADDRESS	34.04511	-118.34873	Full plan check for a CHANGE OF USE FROM RETAIL TO HYDROPONIC AGRICULTURAL nursery ENTERPRISE; Scope includes (1) new 1000-amp service, (9) subpanels and other associated equipment with a total lighting area of 13,061 SQ FT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77582	19041-10000-00998	4551 S GLENCOE AVE STE-145	90292	11	105B153   108	4212007010	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	05/13/2019 12:00:00 AM	ADDRESS	33.9844	-118.43407	Energy plan check for an office T.I. Scope includes new lighting and equipment with a total area of 3174-SQ FT.Bld: 19016-10000-00716	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77583	14041-10000-09074	13601 W GARBER ST	91331	6	201B157   230	2621006019	R1-1	North Valley	Arleta - Pacoima	Arleta		1190.02	Electrical	Electrical	1 or 2 Family Dwelling			04/07/2014 12:00:00 AM	04/07/2014 12:00:00 AM		Permit Finaled	04/10/2014 12:00:00 AM	ADDRESS	34.24907	-118.4294	PV1 3KWdc. 240V. xmfrLESS/Ungnd. STD. 2story. Roofmount. [(1) inverters: {PVI-3.0-OUTD-US }]. [(12)modules: {Canadian Solar {CS6P 250P}}]	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77584	12041-10000-22617	1118 S VALENCIA ST	90015	1	129A205   312	5137024213	C1-1	Central	Westlake	Pico Union		2100.10	Electrical	Electrical	Commercial			09/21/2012 12:00:00 AM			PC Approved	11/29/2012 12:00:00 AM	ADDRESS	34.04659	-118.27332	TI IN THE MAIN ENTRY LOBBY OF AN OFFICE BLDG. EPC IS FOR T24.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77585	19041-10000-10716	1580 E JESSE ST	90021	14	124-5A217 119	5164018010	M3-1-RIO	Central	Central City North	Los Angeles Historic Cultural		2060.31	Electrical	Electrical	Commercial			03/26/2019 12:00:00 AM	05/08/2019 12:00:00 AM		Permit Finaled	12/02/2019 12:00:00 AM	ADDRESS	34.03625	-118.22968	Energy plan check for an INTERIOR TENANT IMPROVEMENT TO EXISTING COMMERCIAL BUILDING. Scope includes new lighting and equipment with a total area of 10,784-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77586	19041-10000-33854	118 N LAUREL AVE	90048	5	138B177   539	5511003017	R1V3	Central	Wilshire	Mid City West		2146.00	Electrical	Electrical	1 or 2 Family Dwelling			09/04/2019 12:00:00 AM	10/03/2019 12:00:00 AM		Permit Finaled	11/13/2019 12:00:00 AM	ADDRESS	34.07493	-118.36462	(ePlan)  Install 1 New Energy Storage System @13.5KWH & 1 New 200A Load Center to existing 5.2KWac PV1 system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77587	16041-10002-43704	9111 N SUNLAND BLVD	91352	6	195B173   632	2408004010	QM1-1-CUGU	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1211.02	Electrical	Electrical	Commercial			05/31/2018 12:00:00 AM			Reviewed by Supervisor	06/19/2018 12:00:00 AM	ADDRESS	34.23513	-118.36751	DELTA 2 CHANGES TO THE APPROVED PLANS. Reducing the size feeder & panel for the current PV system.  Plan Check ONLY. Permit was issued under 16041-20000-43704<<<Install 52.65 kW roof mounted grid tied PV system on (E) commercial warehouse building.  (162) modules with (3) 14.4 kW rated central inverters.>>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77588	18041-20000-40720	21550 W OXNARD ST 1050	91367	3	177B105    85	2146006030	(WC)DOWNTOWN-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills-Warner Center		1371.03	Electrical	Electrical	Commercial			10/24/2018 12:00:00 AM	10/24/2018 12:00:00 AM		Issued	10/24/2018 12:00:00 AM	ADDRESS	34.179	-118.60001	Plan check for Title 24 only in existing space office T.I. Total area: 843 sq ft. B#18016-10000-32304	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77589	15041-20000-41359	800 N HIGHLAND AVE	90038	4	141B185   265	5524004028	[Q]C2-1VL-SN	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			12/08/2015 12:00:00 AM			PC Approved	12/08/2015 12:00:00 AM	ADDRESS	34.08547	-118.33839	PLANCHECK FOR T24 ENERGY ONLY. TENANT IMPROVEMENT TO JUST TIRES AUTOSHOP DUE TO FIRE DAMAGE, NO HAZARDOUS LOCATION PER APPLICANT. 4595 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77590	14041-10000-08286	1217 S VICTORIA AVE	90019	10	129B185   718	5082022010	R1-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	1 or 2 Family Dwelling			03/27/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	08/14/2014 12:00:00 AM	ADDRESS	34.04971	-118.32731	PV1 ROOF MOUNTED MICROINVERTER STANDARD PLAN. TOTAL SYSTEM SIZE 4.32KWAC.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77591	19041-10000-33033	11241 W OTSEGO ST	91601	2	171B173   852	2353003058	R4-1VL	South Valley	North Hollywood - Valley Village	NoHo		1254.01	Electrical	Electrical	Commercial			08/22/2019 12:00:00 AM	09/17/2019 12:00:00 AM		Issued	09/17/2019 12:00:00 AM	ADDRESS	34.16307	-118.37627	NEW FIRE ALARM SYSTEM IN THE BULDING.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77592	11041-10000-18995	5600 N VAN NUYS BLVD	91401	2	174B149   796	2245006044	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1285.00	Electrical	Electrical	Commercial			09/07/2011 12:00:00 AM	08/07/2012 12:00:00 AM		Permit Finaled	10/11/2012 12:00:00 AM	ADDRESS	34.17244	-118.44837	TI FOR NEW  CHIPOLTE  RESTAURANT	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77593	14041-10000-14027	1301 N CATALINA ST 2nd	90027	13	147B197  1088	5543019009	C2-1	Central	Hollywood	East Hollywood		1912.01	Electrical	Electrical	Commercial			05/27/2014 12:00:00 AM	06/10/2014 12:00:00 AM		Permit Finaled	11/20/2015 12:00:00 AM	ADDRESS	34.09569	-118.29526	"Inspector to determine if Supplemental plan check required when lighting fixture model/manufacturer is determined.permit to be pulled at EPC counter only. plan check for energy only. less than 400A with emergency lighting . BLDG#14016-20-05627: Tenant improvement to 2nd story 61'6""x51'office space."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77594	14041-10000-24048	700 WORLD WAY TERMINAL 7	90045	11	090B165   168	4129027***	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			09/03/2014 12:00:00 AM			PC Approved	09/03/2014 12:00:00 AM	ADDRESS	33.94286	-118.39982	Modifying the T-8 Stores & Tech OPS at LAX airportplan chk is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77595	13041-10000-32646	1668 E MAURETANIA ST	90744	15	036B213   608	7425025059	[Q]MR2-1VL	Harbor	Wilmington - Harbor City	Wilmington		2946.20	Electrical	Electrical	Commercial			11/21/2013 12:00:00 AM			PC Approved	11/21/2013 12:00:00 AM	ADDRESS	33.79024	-118.24264	TITLE 24 PART 6 ENERGY WORK FOR COMMERCIAL BUILDING. REMOVING (E) HID LIGHT FIXTURES AND REPLACING WITH NEW FLOURESCENT FIXTURES. TOTAL AREA IN SCOPE OF WORK IS 8741 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77596	12041-10000-05088	6936 N HAZELTINE AVE PV1	91405	2	183B153   741	2216013027	[Q]RD1.5-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.20	Electrical	Electrical	1 or 2 Family Dwelling			03/06/2012 12:00:00 AM	03/23/2012 12:00:00 AM		Permit Finaled	05/14/2012 12:00:00 AM	ADDRESS	34.19685	-118.43982	INSTALL ROOF MOUNTED SOLAR, INTERCONNECT W/ MAIN SERVICE PANEL. (6.24KW) Solar device(s)is/are roof mounted and do not exceed the existing building height at the highest point.(Permit was previously issued under PCIS 12041-10000-04748)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77597	17041-30001-46516	6086 W COMEY AVE	90034	10	123B173   299	5065012029	C2-2D-CPIO	South Los Angeles	West Adams - Baldwin Hills - Leimert			2702.00	Electrical	Electrical	Commercial			01/09/2018 12:00:00 AM	01/09/2018 12:00:00 AM		Issued	01/09/2018 12:00:00 AM	ADDRESS	34.03516	-118.37692	01-09-2018 Changes on an permitted set of plans, Changes include in additional floor receptacle boxes. Changes has been clouded as delta 1 only. *****************************Previous Work Description********************************Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvement. Total lighting area = 3,303 sq. ft.Note: Building application has been generated under 17016-30000-36461	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77598	17041-20000-09842	3837 N WINFORD DR	91356	3	162B121    40	2177047023	RA-1	South Valley	Encino - Tarzana	Tarzana	YES	1398.02	Electrical	Electrical	1 or 2 Family Dwelling			03/28/2017 12:00:00 AM	05/04/2017 12:00:00 AM		Issued	05/04/2017 12:00:00 AM	ADDRESS	34.14066	-118.54977	pv1install roof mounted pv system sized 14kw interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77599	16041-20002-11986	16836 W DEVONSHIRE ST	91344	12	204B133   221	2685002041	C2-1VL	North Valley	Granada Hills - Knollwood	North Hills West		1114.00	Electrical	Electrical	Commercial			08/29/2016 12:00:00 AM			PC Approved	08/29/2016 12:00:00 AM	ADDRESS	34.25731	-118.49947	"8.29.2016 - Plan check for modifications to approved set. Update dimmer switch locations to be in same area/room as lights controlled per T-24. Emergency lights no longer connected as ""night lights"". Switched receptacle controlled by occupancy sensor in office. Update fixtures LEDRD1 and LEDRD2 to dimmable luminaires with same wattage. Changes clouded delta 4.=====Plan check for power and energy. Project site is an existing building. Project scope is a change of use from retail to restaurant. Total lighting area = 4,245 sq. ft.Note: Building application as been created under 15016-10000-25949"	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77600	18041-10000-34160	6844 N OAKDALE AVE	91306	3	183B113   705	2135022036	RA-1-RIO	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1348.00	Electrical	Electrical	Commercial			09/06/2018 12:00:00 AM	09/07/2018 12:00:00 AM		Permit Finaled	10/10/2018 12:00:00 AM	ADDRESS	34.19509	-118.56646	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77601	17041-10001-14968	12837 W NORTH SEAGLASS CIR	90094	11	102B161  1223	4211037***	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	1 or 2 Family Dwelling			06/02/2017 12:00:00 AM			PC Approved	09/13/2017 12:00:00 AM	ADDRESS	33.97473	-118.41872	PC FOR NEW BATTERY BACKUP SYSTEM THAT IS UTILITY INTERACTIVE. PC FOR POWER ONLY. PERMIT ALREADY ISSUED UNDER MASTER.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77602	17041-20000-26375	12415 N RALSTON AVE	91342	7	219B149   618	2507006020	RD3-1XL-CPIO	North Valley	Sylmar	Sylmar		1070.20	Electrical	Electrical	1 or 2 Family Dwelling			08/02/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	12/08/2017 12:00:00 AM	ADDRESS	34.29588	-118.45099	Plan check for a PV1 roof-mounted PV system. System size is 15 kWac and consists of (60) modules, (60) micro-inverters, and (1) load center.Note: $0.00 permit fee due to CA Senate Bill 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77603	12041-10000-15199	5420-5430 N SAN FERNANDO ROAD WEST BLDG A&B	90039	13	165B201   257	5593005048	M2-1	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			06/29/2012 12:00:00 AM	11/05/2012 12:00:00 AM		Issued	11/05/2012 12:00:00 AM	ADDRESS	34.15089	-118.27467	BLDG A => 5430 SANFERNANDO RD. SERVICE UPGRADE TO 1600 AMP PLUS NEW PANELS & LOAD. BLDG B => 5420 SANFERNANDO RD. SERVICE UPGRADE TO 800 AMP AND 4 NEW AC UNITS (BLDG B ==>PERMIT # 12041-10000-26134)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77604	14041-10000-07194	1707 N NAUD ST	90012	1	136-5A219  95	5409002019	UV(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			03/18/2014 12:00:00 AM	03/18/2014 12:00:00 AM		Permit Finaled	04/01/2014 12:00:00 AM	ADDRESS	34.06889	-118.22636	T24, REMOVE EXISTING HID LIGHT FIXTURES WITH NEW FLORESCENT LIGT FIXTURES. TOTAL AREA 6704 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77605	17041-20000-24372	23646 W NADIR ST	91304	12	192B093   437	2005018033	RE11-1	North Valley	Chatsworth - Porter Ranch	West Hills		1132.31	Electrical	Electrical	1 or 2 Family Dwelling			07/19/2017 12:00:00 AM	08/10/2017 12:00:00 AM		Permit Finaled	08/31/2017 12:00:00 AM	ADDRESS	34.21959	-118.64257	Plan check for 4 kWac coupled battery backup system (connect to existing solar pv system) for SFD.(1) Outback Radian GS4048A and (8) 12V DC batteries.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77606	13041-10000-36205	944 S LOS ANGELES ST	90015	14	126A209   136	5145016047	M2-2D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			12/30/2013 12:00:00 AM	12/30/2013 12:00:00 AM		Permit Finaled	02/04/2014 12:00:00 AM	ADDRESS	34.03976	-118.25524	permit to be pulled at EPC counter only. PC for energy only. Scope does not include emergency lighting.TI TO (E) BLDG. REMOVE (E) HID LIGHT FIXTURES & INSTALL (N) DWP-program light fixtures. ALL (E) WIRING, CONDUIT, AND CONTROLS TO REMAIN.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77607	13041-20001-36075	17217 W CANTLAY ST	91406	6	186B133  1101	2227016029	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1319.00	Electrical	Electrical	1 or 2 Family Dwelling			12/27/2013 12:00:00 AM			PC Approved	01/04/2014 12:00:00 AM	ADDRESS	34.20219	-118.5082	(((Expedite fees)))PV1 TRANSFORMERLESS SYSTEM. TOTAL SYSTEM SIZE 3.8KWAC. USING OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77608	14041-20001-10275	19121 W LIGGETT ST	91324	12	198B121   273	2762019006	RA-1	North Valley	Northridge	Northridge West		1153.01	Electrical	Electrical	1 or 2 Family Dwelling			04/18/2014 12:00:00 AM			PC Approved	04/30/2014 12:00:00 AM	ADDRESS	34.24047	-118.54997	EXPEDITE PER CUSTOMER REQUESTPV1 INSTALL ROFF MOUNTED PV SYSTEM SIZED 8.5KW INTERCONNECT WITH MAIN PANEL.(2) TRANSFORMERLESS INVERTERS: SOLAREDGE SE3800A	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77609	10041-20000-22067	20929 W VENTURA BLVD #33	91367	3	171B109    63	2167001014	C4-1LD, P-1LD	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1375.02	Electrical	Electrical	Commercial			11/04/2010 12:00:00 AM	12/27/2010 12:00:00 AM		Permit Finaled	03/02/2011 12:00:00 AM	PIN	34.16716286	-118.58942399	T.I. to a take-out Deli.  Install branch circuits and general/emergency lighting.  Plan check for energy only.Permit includes new subpanel, ckts, and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77610	16041-10000-44686	3678 N BARHAM BLVD (BUILDING-K)	90068	4	162B185     5	5581003003	R3-1, RE40-1-H	Central	Hollywood	Hollywood Hills West	YES	1897.01	Electrical	Electrical	Commercial			12/30/2016 12:00:00 AM	04/04/2018 12:00:00 AM		Permit Finaled	07/18/2018 12:00:00 AM	ADDRESS	34.13961	-118.34133	"NEW UNIT PANELS, NEW ""STACKED"" WASHERS & DRYER CIRCUIT AND NEW MICROWAVE CIRCUIT. STUDIO UNITS WILL NOT INCLUDE A WASHER AND DRYER CIRCUIT."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77611	18041-10000-33307	1338 W 228TH ST	90501	15	045B193   416	7347018032	M2-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			08/30/2018 12:00:00 AM	08/31/2018 12:00:00 AM		Permit Finaled	09/21/2018 12:00:00 AM	ADDRESS	33.81887	-118.30102	REPLACE OUTDOOR EXISTING HID FIXTURES WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77612	19041-20000-31337	5826 W CARLTON WAY	90028	13	148-5A191 248	5545010017	[Q]R4-1VL	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Apartment			08/12/2019 12:00:00 AM	03/13/2020 12:00:00 AM		Permit Finaled	02/10/2021 12:00:00 AM	ADDRESS	34.10023	-118.3168	New 600A 240/120V 1ph-3w service for existing 35-unit apartment building.  Plan check for power.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77613	15041-10000-08955	2251 S BARRY AVE	90064	11	123B149   459	4260013012	M2-1	West Los Angeles	West Los Angeles	West Los Angeles		2676.00	Electrical	Electrical	Commercial			03/26/2015 12:00:00 AM	03/26/2015 12:00:00 AM		Permit Finaled	06/12/2015 12:00:00 AM	ADDRESS	34.03357	-118.44596	new fire alarm system.  45 devices.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77614	15041-20000-02622	12492 W OSPREY LANE UNIT 3	90094	11	102B161  1264	4211034058	R4(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			01/28/2015 12:00:00 AM	02/11/2015 12:00:00 AM		Permit Finaled	08/03/2015 12:00:00 AM	ADDRESS	33.97868	-118.4109	PV2INSTALL ROOF MOUNTED PV SYSTEM SIZED 3KW INTERCONNECTED WITH MSP.THIS IS UNIT #3 OF THREE UNITS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77615	13041-10000-34350	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			12/10/2013 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	33.98489	-118.42552	"TITLE 24 PART 6 ENERGY FOR  (E) ""DIRECT TV"" BROADCAST CENTER MONITOR ROOM 552, ROOM 691-N. SCOPE OF WORK < 400A. PROJECTED AREA IN LIGHTING SCOPE OF WORK 542 SQ FT. ELECTRICAL PERMIT TO BE PULLED @ ELECTRICAL COUNTER. 11 BR CKTS(SEE INSPECTION FEE ; REMOVE PLAN-CHECK ONLY UPON THE RETURNING OF CONTRACTOR)."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77616	12041-10000-03944	2006 E CESAR E CHAVEZ AVE	90033	14	129A223   108	5183001025	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2044.10	Electrical	Electrical	Commercial			02/22/2012 12:00:00 AM			Reviewed by Supervisor	03/07/2012 12:00:00 AM	ADDRESS	34.04865	-118.21253	Plan check power and energy for dental office.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77617	19041-10000-53324	712 S OLIVE ST	90014	14	129A209   198	5144013036	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			12/26/2019 12:00:00 AM			PC Info Complete	04/23/2020 12:00:00 AM	ADDRESS	34.0462	-118.25568	FULL PC FOR A T.I. TOTAL AFFECTED AREA 8051 SQFT. SCOPE OF WORK INCLUDES INSTALLATION OF NEW BRANCH CIRCUITS TO  EXISTING PANEL. SUBMITTED & EXPEDITED PER APPLICANT REQUEST.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77618	16041-10000-44149	15350 W SHERMAN WAY 2ND FLR-#200	91406	6	183B145   794	2222029014	C2-1VL	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1277.12	Electrical	Electrical	Commercial			12/15/2016 12:00:00 AM	12/30/2016 12:00:00 AM		Permit Finaled	02/24/2017 12:00:00 AM	ADDRESS	34.20099	-118.46808	PC for energy only to exiting low rise building (offices). TI on second floor. Adding new equipment load which doesnt exceed the 400Amps. New lighting. Total SQFT 5661.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77619	14041-20000-13668	16936 W SUPERIOR ST	91343	12	201B133   392	2686025033	RS-1	North Valley	Northridge	Northridge East		1173.02	Electrical	Electrical	1 or 2 Family Dwelling			05/22/2014 12:00:00 AM	06/02/2014 12:00:00 AM		Permit Finaled	09/09/2014 12:00:00 AM	ADDRESS	34.24727	-118.50143	7.24KW PV1 roof-mounted system wtih (32) Yingli YL250P modules, and (2) Power-One-PVI-4.2 and 3.0-OUTD-S-US transformerless inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77620	16041-10000-24272	1545 W 223RD ST	90501	15	048B193   643	7346020027	R1-1	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	1 or 2 Family Dwelling			07/11/2016 12:00:00 AM	07/12/2016 12:00:00 AM		Permit Finaled	04/17/2017 12:00:00 AM	ADDRESS	33.82465	-118.30534	PV1, rooftop solar installation on SFD, 6kW AC system.    (1) PVI-6000US   (20) SPR-E20-327* Standard plan is being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77621	12041-10000-28318	3434 E 4TH ST	90063	14	124-5A227 453	5186010812	C2-1	East Los Angeles	Boyle Heights	Boyle Heights		2039.00	Electrical	Electrical	Commercial			11/27/2012 12:00:00 AM	06/05/2013 12:00:00 AM		Permit Finaled	07/22/2013 12:00:00 AM	ADDRESS	34.03336	-118.19591	Install three new Fuel cells that supply to an existing 4000A bus.  Install new 800A fuel cell panel.  Plan check for power only.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77622	14041-10000-04846	19600 W PLUMMER ST	91324	12	198B117    69	2761036025	(Q)C4-1, P-1	North Valley	Chatsworth - Porter Ranch	Northridge West		1133.01	Electrical	Electrical	Commercial			02/21/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	08/12/2014 12:00:00 AM	ADDRESS	34.2426	-118.5602	PLANCHECK FOR POWER AND ENERGY. FIRST TIME TENANT. bUILDING P #  14016�40000�01306     SUBDIVIDE RETAIL SPACE INTO TWO TENANT SPACES. T.I. FOR NEW RETAIL SPACE (3373 SQ FT) BUILD NEW RESTROOMS. SUSPENDED CEILINGS PER PLAN. MODIFY PORTION OF EXISTING STOREFRONT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77623	11041-10000-16209	20832 W VANOWEN ST	91306	3	180B109    33	2148006025	(Q)C1-1VL, (Q)P-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Winnetka		1349.04	Electrical	Electrical	Commercial			08/02/2011 12:00:00 AM			PC Approved	08/02/2011 12:00:00 AM	ADDRESS	34.19357	-118.58726	T.I.  Existing 7-Eleven.  Rennovating the light fixtures in the retail area only.  Replacing the existing light fixtures with LED fixtures.  Plan check is for energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77624	16041-20001-11029	18535 W BURBANK BLVD	91356	3	174B125   372	2160003004	(T)(Q)R3-1	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Apartment			08/15/2017 12:00:00 AM			PC Approved	08/15/2017 12:00:00 AM	ADDRESS	34.1725	-118.53724	08/15/2017 Changes to an approved set of plans. All changes have been clouded and marked as Delta A. Unit count has been reduced from 14 to 13. Changes have been made to the floor plans to reflect the reduction of the unit count.*****Previous Work Description*****NEW THREE STORY (14 UNITS) APARTMENT BUILDING - TYPE VA - OVER ONE LEVEL OF OPEN PARKING GARAGE BASEMENT - TYPE IA.  PLAN CHECK FOR POWER AND ENERGY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77625	19041-10001-15030	10310 N SEPULVEDA BLVD	91345	7	204B145   259	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/09/2019 12:00:00 AM			PC Approved	12/03/2019 12:00:00 AM	ADDRESS	34.25776	-118.46707	PLAN CHECK ONLY. DELTA 1 CHANGES TO AN APPROVED SET. ADDITION OF PANEL D FOR FUTURE TENANT. NO ADDED LOADS. ADDITIONAL FEES ARE ADDED/PAID UNDER THE ORIGINAL PERMIT((Power plan check for a core/shell tenant improvement. Scope includes a new distribution panel and equipment.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77626	18041-20000-37203	1600 W HILL DR	90041	14	165A227   199	5669014018	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock	YES	1810.00	Electrical	Electrical	1 or 2 Family Dwelling			09/28/2018 12:00:00 AM	09/28/2018 12:00:00 AM		Issued	09/28/2018 12:00:00 AM	ADDRESS	34.14459	-118.20066	Plan check for a PV1 roof-mounted PV system. System size is 5.51 kWdc/4.6 kWac and consists of (1) inverter and (19) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77627	18041-30000-45370	400 S BURNSIDE AVE TOWER-#37	90036	4	135B181   198	5509005006	A1-1XL-O, R4-2-O, RD1.5-1-O	Central	Wilshire	Mid City West		2145.02	Electrical	Electrical	Apartment			11/29/2018 12:00:00 AM	09/09/2019 12:00:00 AM		Permit Finaled	01/20/2022 12:00:00 AM	ADDRESS	34.0675	-118.35148	PC FOR POWER ONLY  FOR SERVICE UPGRADE TO A 13 STORY APARTMENT BUILDING. SCOPE INCLUDES NEW SERVICE 4000A 3 PH 120/208VWITH 3000A RES. DISTRIBUITION AND 800A  HOUSE LOADS. ALSO NEW METER SECTIONS IN EACH FLOOR. 125A BREAKERS AND UNITS PANEL WILL BE INSTALLED AS UNIT IS VACANT.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77628	15041-10000-09137	5357 N RIVERTON AVE	91601	2	171B177   158	2416011010	MR1-1VL	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1253.20	Electrical	Electrical	Commercial			03/27/2015 12:00:00 AM	03/27/2015 12:00:00 AM		Permit Finaled	04/10/2015 12:00:00 AM	ADDRESS	34.16818	-118.36549	T24 ONLY. REMOVE HID LIGHT FIXTURES AND REPLACE WITH LED FIXTURES. TOTAL AREA 10800 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77629	14041-10000-25743	936 S OLIVE ST	90015	14	127-5A209 193	5139004014	[Q]R5-4D	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			09/18/2014 12:00:00 AM	04/07/2015 12:00:00 AM		Permit Finaled	06/28/2016 12:00:00 AM	ADDRESS	34.04287	-118.25873	PLANCHECK FOR TEMPORARY POWER. 600 AMP SERVICE.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77630	19041-10000-07625	1055 W 7TH ST 25TH FLR	90017	1	130-5A207 221	5143028019	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			03/04/2019 12:00:00 AM	03/04/2019 12:00:00 AM		Permit Finaled	06/17/2019 12:00:00 AM	ADDRESS	34.0507	-118.26334	T-24 PLAN CHECK FOR A TI TO AN EXISTING OFFICE.  NO CHANGE OF USE. SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL AFFECTED AREA IS 17180 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77631	12041-10000-25169	5185 W SUNSET BLVD 2nd floor	90028	13	147A191    51	5545011031	(Q)C2-2D-SN	Central	Hollywood	Hollywood Studio District		1910.00	Electrical	Electrical	Commercial			10/22/2012 12:00:00 AM			PC Approved	10/23/2012 12:00:00 AM	PIN	34.09843489	-118.31651408	Plan check for title 24 and emergency lights on second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77632	10041-10003-20309	5200 W WILSHIRE BLVD	90036	4	132B181    30	5507024010	[T][Q]C4-2D-CDO	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Apartment			03/28/2013 12:00:00 AM	05/24/2013 12:00:00 AM		Permit Finaled	04/04/2014 12:00:00 AM	ADDRESS	34.06194	-118.3435	REVISIONS TO APPROVED SET OF PLANS; LIST OF CHANGES ARE ATTACHED TO SUBMITTAL APPLICATION (FY)NEW MIXED USE APT (478 UNITS) 6 stories	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77633	15041-10000-20890	1248 W YOSEMITE DR	90041	14	160-5A229 289	5480020025	R1-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1832.22	Electrical	Electrical	1 or 2 Family Dwelling			07/01/2015 12:00:00 AM	07/01/2015 12:00:00 AM		Refund in Progress	06/27/2016 12:00:00 AM	ADDRESS	34.13336	-118.19276	PV1, ROOF MTD, 5.3 KW PV ARRAY(20) MODULES: KYOCERA #KU2656ZPA(1) INVERTER: SOLAREDGE #SE3800A-US-ZB-U	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77634	15041-10001-22663	3165 W 6TH ST	90020	13	135B197   953	5077003013	C2-1	Central	Wilshire	Rampart Village		2111.20	Electrical	Electrical	Commercial			02/28/2018 12:00:00 AM	03/20/2018 12:00:00 AM		Permit Finaled	07/14/2018 12:00:00 AM	ADDRESS	34.06383	-118.29074	Delta 6 changes- changes to lighting plan, new circuits, and relocate the service equipment(((Full plan check for an Ihop Restaurant expansion T.I located in a MATHANE ZONE. Scope includes a new 600-Amp  3-phase 4-wire 120/208V service, 6-panels, 7-equipment, 97-circuits and a total of  22,197-SQ feet for T-24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77635	17041-20000-31665	10430 N SEPULVEDA BLVD	91345	7	207B145   770	2649019032	(T)(Q)C2-1	North Valley	Mission Hills - Panorama City - North Hills	Mission Hills		1096.04	Electrical	Electrical	Commercial			09/05/2017 12:00:00 AM	02/02/2018 12:00:00 AM		Permit Finaled	09/05/2018 12:00:00 AM	ADDRESS	34.26014	-118.46701	First time tenant improvement for commercial building - retail space.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77636	14041-20000-05150	12698 W SANDHILL LANE UNIT2	90094	11	102B161  1247	4211034028	C2(PV)	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2756.02	Electrical	Electrical	Commercial			02/25/2014 12:00:00 AM	04/30/2014 12:00:00 AM		Permit Finaled	06/06/2016 12:00:00 AM	ADDRESS	33.97714	-118.41552	PC FOR SERIES OF roof mounted PHOTOVOLTAIC SYSTEMS FOR NEW CONDOS. THIS SYSTEM IS SPECIFIC FOR UNIT 2. SYSTEM SIZE 3KW AC. SYSTEM IS TIED TO MAIN SERVICE SERVING OTHER UNITS. THIS IS PLAN CHECK AND PERMIT SUBMITTAL 2 OF 3.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77637	13041-10001-35391	1117 N WESTMORELAND AVE	90029	13	144B197   642	5542027036	RD1.5-1XL	Central	Hollywood	East Hollywood		1913.01	Electrical	Electrical	1 or 2 Family Dwelling			12/26/2013 12:00:00 AM			PC Approved	06/26/2014 12:00:00 AM	ADDRESS	34.09145	-118.28797	Expedited RSES plan check per applicant request.{{PV1, Install 4.5 kW DC roof-mounted solar array, interconnect with main service panel for a 2 story house. (1)Transformerless inverter: Solaredge SE 5000A-US. (18) modules Trina Solar TSM-250PA05.18.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77638	17041-10001-26638	3201 S HOOVER ST #8C3	90089	9	121-5A201 145	5039020035	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			10/13/2017 12:00:00 AM			PC Approved	10/13/2017 12:00:00 AM	ADDRESS	34.0255	-118.28448	10/13/2017 Changes to an approved set of plan. Changes include reduce breaker size from 400A to 250A and and feeder size and panel size, all load to remain the same. Changes has been clouded	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77639	19041-10000-09142	12239-12241 W FOOTHILL BLVD	91342	7	213B165   158	2531003014	[Q]M1-1-CUGU	North Valley	Arleta - Pacoima	Foothill Trails District		1042.04	Electrical	Electrical	Commercial			03/13/2019 12:00:00 AM			PC Approved	03/13/2019 12:00:00 AM	ADDRESS	34.28194	-118.40268	Energy plan check for a single story, bread factory, T.I. Scope includes new lighting and equipment with a total area of 3480-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77640	16041-10001-11737	5283 N EAGLE DALE AVE	90041	14	165A217    54	5680027003	RD1.5-1	East Los Angeles	Northeast Los Angeles	Eagle Rock		1813.00	Electrical	Electrical	1 or 2 Family Dwelling			04/05/2016 12:00:00 AM			PC Approved	04/20/2016 12:00:00 AM	ADDRESS	34.14517	-118.22823	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{{PV1, INSTALL 5.7 KW DC ROOF-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE. (22) MODULES: SOLARWORLD SW260 POLY(1) INVERTERS FRONIUS PRIMO 5.0-1 240V:}}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77641	16041-10001-33506	2327 W 37TH ST	90732	15	009B185    10	7563031011	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			09/21/2016 12:00:00 AM			PC Approved	11/04/2016 12:00:00 AM	ADDRESS	33.72338	-118.32705	Expedite fees only.  Installation of new roof mounted solar pv array on existing single family dwelling.  Interconnect with existing 2.5 kWac system.  New SolarEdge SE3800A-US inverter with 20 new Trina Solar TSM-255 modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77642	14041-20000-22284	7900 W SUNSET BLVD	90046	4	147B177  1008	5554001001	C4-1D	Central	Hollywood	Hollywood Hills West		1898.00	Electrical	Electrical	Commercial			08/18/2014 12:00:00 AM			Corrections Issued	08/18/2014 12:00:00 AM	ADDRESS	34.09788	-118.36194	TI to (E) Rite-Aid store, replacement of can lights on sales floor and installation of equipment for yogurt/ice cream station.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77643	14041-10001-21146	4515 SHERMAN OAKS AVE	0	11	168B145	2283017002						1414.00	Electrical	Electrical	1 or 2 Family Dwelling			08/06/2014 12:00:00 AM			PC Approved	09/30/2014 12:00:00 AM				EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.<<PV1, INSTALL 1071 KW DC ROOF-MOUNTED SOLAR ARRAY ON A 1-STORY HOUSE INTERCONNECT WITH MAIN SERVICE PANEL.(42) MODULES: KYOCERA KD255GX-LFB3(2) INVERTERs: SOLAREDGE SE3800A-US-ZB-U>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77644	14041-10001-05672	128 N ELLITA PL	90042	1	150A227    23	5468017008	RD2-1-HPOZ	East Los Angeles	Northeast Los Angeles	Historic Highland Park		1838.10	Electrical	Electrical	1 or 2 Family Dwelling			04/04/2014 12:00:00 AM	04/04/2014 12:00:00 AM		Permit Expired	04/29/2016 12:00:00 AM	ADDRESS	34.10733	-118.19953	(((4/4/2014- CHANGES MADE TO APPROVED SET OF PLANS. ADDED 4 MODULES TO EXISTING SYSTEM.))))PV1. ROOF MOUNTED SOLAR SYSTEM.  TRANSFORMERLESS INVERTER. TWO STORY. SYSTEM SIZE: 3.0KWAC	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77645	17041-20001-33488	9363 N SHOSHONE AVE	91325	12	198B129    98	2766020027	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2017 12:00:00 AM			PC Approved	09/25/2017 12:00:00 AM	ADDRESS	34.2412	-118.5179	EXPEDITE PER APPLICANT REQUEST.Plan check for solar pv system, roof-mounted array on SFD.10.4kW ungrounded system [3.8+6.6].(33) 325W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77646	13041-20000-16385	2801 W 6TH ST	90057	1	135A201   129	5155011001	C2-2	Central	Westlake	Rampart Village		2087.10	Electrical	Electrical	Commercial			06/20/2013 12:00:00 AM	07/19/2013 12:00:00 AM		Permit Finaled	09/03/2013 12:00:00 AM	ADDRESS	34.06351	-118.28332	RENOVATION OF EXISTING SCHOOL FOR NEW SCHOOL. NEW LIGHITING AND, OUTLETS, AND PANELS. TO BE CONNECTED TO EXISTING SERVICE. PLACE OF ASSEMBLY. FULL PLAN CHECK. POWER AND ENERGY. Conduit Only Variance Filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77647	19041-10000-00583	2113 N MOUNT OLYMPUS DR	90046	4	151-5A175  29	5569026009	RE40-1-H-HCR	Central	Hollywood	Hollywood Hills West	YES	1941.02	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2019 12:00:00 AM	02/22/2019 12:00:00 AM		Permit Finaled	06/27/2019 12:00:00 AM	ADDRESS	34.11092	-118.36751	NOTE: FEES ARE $0 DUE TO ASSEMBLY BILL 1222.NEW GROUND MOUNT SOLAR SYSTEM CONSIST OF 64 MODULES (PANASONIC N330) , 64 OPTIMIZER (SE P400) AND 2 CENTRAL INVERTERS (SE11400A-US & SE7600H-US).  SYSTEM SIZE IS 21.12KWdc and 19KWac.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77648	11041-10003-14814	380 W WORLD WAY	90045	11	090B165   187	4129027902	LAX	West Los Angeles	Los Angeles International Airport	Westchester - Playa del Rey		9800.28	Electrical	Electrical	Commercial			02/07/2013 12:00:00 AM			PC Info Complete	03/12/2014 12:00:00 AM	PIN	33.94094587	-118.40577128	PLAN REVIEW OF PLANS SHOWING CHANGES MADE IN THE FIELD; THE PROJECT AT TOM BRADLEY TERMINAL IS ON GOING AND OTHER CHANGES WILL BE MADE BEFORE THE PROJECT IS COMPLETED. THE CHANGES INCLUDE UPDATE PANEL SCHEDULES ;REVISIONS TO LIGHTING SYSTEM AND UPDATED TITLE 24 COMPLIANCE FORMSRenovation and addition to existing Tom Bradley International Terminal building, LAX.  PLAN CHECK IS FOR POWER AND ENERGY.   FIRE ALARM IS ON A SEPERATE APPLICATION.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77649	17041-20000-18737	5665 N RHODES AVE	91607	2	174B165   492	2340017014	R1-1	South Valley	North Hollywood - Valley Village	Greater Valley Glen		1238.00	Electrical	Electrical	1 or 2 Family Dwelling			06/05/2017 12:00:00 AM	06/21/2017 12:00:00 AM		Permit Finaled	06/28/2017 12:00:00 AM	ADDRESS	34.17399	-118.40322	PV1INSTALLATION OF 20 ADDITIONAL PV MODULES TO AN EXISTING PV SYSTEM, SIZED 16.4KW INTERCONNECTED WITH MSP.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77650	14041-20007-17303	5800 W SUNSET BLVD	90028	13	147A191   147	5545016007	M1-1	Central	Hollywood	Hollywood Studio District		1909.02	Electrical	Electrical	Commercial			12/08/2016 12:00:00 AM			PC Approved	12/08/2016 12:00:00 AM	ADDRESS	34.09728	-118.31693	Changes to approved set.  Delta-17 changes: miscellaneous revisons to mechanical equipment ratings and connection points - feed cooling tower spray pumps from panel 14LA.  *****Previous Work Description*****A new 14-story above grade core & shell only ,  office tower of approximately 314,495 square feet, including one level of subterranean parking. PC FOR POWER AND ENERGY. BUILDING SERVICE FROM CUSTOMER SUBSTATION. 4160V SERVICE. NON HAZARDOUS	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77651	13041-20000-02825	9872 N ARLETA AVE	91331	6	201B153   215	2645009057	R1-1	North Valley	Arleta - Pacoima	Arleta		1191.00	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2013 12:00:00 AM	02/15/2013 12:00:00 AM		Permit Finaled	05/02/2013 12:00:00 AM	ADDRESS	34.24977	-118.43394	New 10.1kw PV system for an existing single-family residence	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77652	19041-10001-02295	953 S ELDEN AVE	90006	1	132B197  1149	5076003032	R4-1	Central	Wilshire	MacArthur Park		2134.01	Electrical	Electrical	Commercial			01/18/2019 12:00:00 AM			PC Approved	02/19/2019 12:00:00 AM	ADDRESS	34.05406	-118.28789	FEE EXPEDITE PLAN CHECK FOR ROOF MOUNTED 27.6KVA PV2 SYSTEM CONSISTING OF 3 CENTRAL INVERTERS ((2)SE10000H-US&(1)SE7600H-US) WITH 75 MODULES USING P400 OPTIMIZERS	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77653	14041-10000-03064	7145 S TRASK AVE	90293	11	096B149   653	4116019015	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2781.02	Electrical	Electrical	1 or 2 Family Dwelling			02/04/2014 12:00:00 AM	03/27/2014 12:00:00 AM		Permit Finaled	07/16/2014 12:00:00 AM	ADDRESS	33.95624	-118.4452	PV1, Install 6 KW DC roof-mounted solar array on a 2-story home, interconnect with existing service panel.(1)Transformerless inverter: SOLAREDGE SE5000A-US-ZB-U(24) Modules: TRINA SOLAR TSM-250PA05.18	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77654	18041-20000-20603	12145 W HOLLYGLEN PL	91604	2	162B165   645	2369007007	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.01	Electrical	Electrical	1 or 2 Family Dwelling			06/04/2018 12:00:00 AM	06/18/2018 12:00:00 AM		Issued	06/18/2018 12:00:00 AM	ADDRESS	34.13989	-118.39771	Plan check for PV roof mounted system. System size: 15.2kWac with 69 modules and 2 inverters(7.6kw) connected to 400A Service.$0 permit fee per State Senate Bill SB 1222.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77655	16041-20000-40544	9700 N WOODMAN AVE A016	91331	6	201B149   343	2644024025	[Q]C2-1VL	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	Commercial			11/16/2016 12:00:00 AM	11/17/2016 12:00:00 AM		Permit Finaled	08/14/2017 12:00:00 AM	ADDRESS	34.24599	-118.44723	TI TO AN EXISTING COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS TO NEW PANEL NEWLY CONNECTED LOAD < 400AMPS.  PLAN CHECK FOR ENERGY AND EM LIGHING ONLY.TOTAL SQUARE FOOTAGE 1933.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77656	17041-10000-39814	9500 S BROADWAY BLDG #2	90003	8	093A203    88	6053006053	C2-1	South Los Angeles	Southeast Los Angeles	Empowerment Congress Southeast Area		2405.00	Electrical	Electrical	Commercial			11/03/2017 12:00:00 AM	11/03/2017 12:00:00 AM		Permit Finaled	11/21/2017 12:00:00 AM	ADDRESS	33.94989	-118.27798	Remove outdoor HID Fixtures and replace it with new LED fixtures. Title 24 only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77657	19041-10000-14196	6067 W WILSHIRE BLVD	90036	4	135B177   428	5508017004	[Q]C2-2-CDO	Central	Wilshire	Mid City West		2151.01	Electrical	Electrical	Commercial			04/18/2019 12:00:00 AM			PC Info Complete	04/25/2019 12:00:00 AM	ADDRESS	34.0631	-118.36086	Plan check for title 24 only. Scope work includes adding new lights and circuits to a new structure within an exiting building. Total affected area is 510 SQFT	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77658	19041-20000-00818	9143 W CRESTA DR	90035	5	129B169  1274	4305026013	R1V2	West Los Angeles	West Los Angeles	South Robertson		2695.00	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2019 12:00:00 AM	02/13/2019 12:00:00 AM		Permit Finaled	03/15/2019 12:00:00 AM	ADDRESS	34.04646	-118.38971	PV1.  Install 14.52 kW roof mounted grid tied PV system.  (44) modules with (2) 7.6 kW rated string inverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77659	16041-10000-38221	2402 E ANAHEIM ST	90744	15	030B213   113	7440002916	[Q]M3-1	Harbor	Wilmington - Harbor City	Wilmington		9800.14	Electrical	Electrical	Commercial			10/27/2016 12:00:00 AM	02/14/2017 12:00:00 AM		Permit Finaled	11/13/2017 12:00:00 AM	ADDRESS	33.78054	-118.23195	Plan check for  cogeneration power plant medium voltage in oil refinery facility. Net metering @ 34.5KV customer side 13.8KV and 480V distribution.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77660	13041-10000-33122	1000 W ELYSIAN PARK AVE	90012	1	138B213   107	5415018010	A1-1XL	Central	Central City North	Historic Cultural	YES	1977.00	Electrical	Electrical	Commercial			11/26/2013 12:00:00 AM	02/12/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.07196	-118.24719	TI of left field bullpen overlook for Dodger Stadium.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77661	13041-10000-27223	2314 S UNION AVE	90007	1	124-5A201 291	5124007018	C2-1L-O-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2244.10	Electrical	Electrical	Commercial			10/01/2013 12:00:00 AM	01/07/2014 12:00:00 AM		Permit Finaled	04/28/2014 12:00:00 AM	ADDRESS	34.0344	-118.28361	Tenant improvement in existing restaurantplan chk and permit is for title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77662	15041-20000-42531	6138 N ALONZO AVE	91316	5	177B129   282	2123027019	R1-1-RIO	South Valley	Reseda - West Van Nuys	Encino		1329.00	Electrical	Electrical	1 or 2 Family Dwelling			12/16/2015 12:00:00 AM	12/17/2015 12:00:00 AM		Issued	12/17/2015 12:00:00 AM	ADDRESS	34.18159	-118.52195	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 3.3KWac/3.15KWdc(10)MODULES-CANADIANSOLAR: CS6X-315P(10)OPTIMIZERS-SOLAREDGE QP400-MV (1)INVERTER-SOLAREDGE: SE-3000A-US	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77663	18041-20000-23662	20420 W QUEDO DR	91364	3	169-5A111  92	2166022003	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills-Warner Center		1375.01	Electrical	Electrical	1 or 2 Family Dwelling			06/25/2018 12:00:00 AM	06/25/2018 12:00:00 AM		Permit Finaled	07/20/2018 12:00:00 AM	ADDRESS	34.15844	-118.57815	Plan check for a PV1 roof-mounted PV system. System size is 14.52 kWdc/13.56 kWac-CEC and consists of (2) 7.6 kWac rated inverters, (44) modules, and (1) load center.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77664	13041-10000-32569	4009 N COLDWATER CANYON AVE	91604	2	162B161   222	2385027008	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1439.02	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2013 12:00:00 AM	11/20/2013 12:00:00 AM		Permit Finaled	12/12/2013 12:00:00 AM	ADDRESS	34.1429	-118.41385	PV1.  MICROINVERTER STD PLAN. SYSTEM SIZE: 5 KW DC.  W/ 100 LOAD CENTER.(20) REC250PE SOLAR PANELS(20) ENPHASE M215 MICROINVERTERS	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77665	11041-10000-17416	3450 W WILSHIRE BLVD # 900	90010	10	132B197    51	5094002***	C4-2, P-2, PB-2	Central	Wilshire	Wilshire Center - Koreatown		2123.04, 2124.10	Electrical	Electrical	Commercial			08/16/2011 12:00:00 AM	08/26/2011 12:00:00 AM		Permit Finaled	04/10/2012 12:00:00 AM	ADDRESS	34.06151	-118.29958	ti in officesplan chk is for title 24 and 1 ea emergency ckt	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77666	14041-10000-13157	12125 W VENICE BLVD	90066	11	114B157  1334	4248030035	C2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2719.02	Electrical	Electrical	Commercial			05/16/2014 12:00:00 AM	12/03/2014 12:00:00 AM		Permit Finaled	04/03/2015 12:00:00 AM	ADDRESS	34.0054	-118.43084	Plan check for power and energy. place of assembly. Engineer lic#20701 not showing up. Fire alarm variance to be filed. *IEG submittal to be assigned to mehdi. BLDG#14016-30-05628: Interior remodel of existing bowling alley	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77667	17041-20001-02411	12862 W FILMORE ST	91331	7	213B161   865	2533029075	(T)(Q)R2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1042.03	Electrical	Electrical	1 or 2 Family Dwelling			01/24/2017 12:00:00 AM			PC Approved	02/22/2017 12:00:00 AM	ADDRESS	34.27778	-118.41308	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 3.8 kWac and consists of (1) inverter and (12) modules. Standard plan is not being used.Note: This is (1) unit of a duplex. Both units will have a PV system installed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77668	15041-20000-02511	3276 S STONER AVE	90066	11	117B153   502	4250006011	R1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Mar Vista		2715.00	Electrical	Electrical	1 or 2 Family Dwelling			01/27/2015 12:00:00 AM	02/02/2015 12:00:00 AM		Permit Finaled	02/21/2015 12:00:00 AM	ADDRESS	34.01757	-118.43543	PV1 SFD. TOTAL SYSTEM SIZE 7.6KW AC USING TRANSFORMELRESS INVERTER. NONSTANDARD PLAN. USING POWER OPTIMIZERS.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77669	13041-20000-16443	612 E 118TH ST PV-1	90059	15	084B205   726	6084004004	R1-1	South Los Angeles	Southeast Los Angeles	Harbor Gateway North		2410.02	Electrical	Electrical	1 or 2 Family Dwelling			06/20/2013 12:00:00 AM	06/21/2013 12:00:00 AM		Permit Expired	07/16/2015 12:00:00 AM	ADDRESS	33.92633	-118.26463	PV-1. Plan check for standard inverter. ONe 3kW inverter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77670	16041-20000-29498	847 S BROADWAY	90014	14	127-5A209 174	5144017038	[Q]C5-4D-CDO-SN	Central	Central City	Downtown Los Angeles		2073.01	Electrical	Electrical	Commercial			08/19/2016 12:00:00 AM	08/29/2016 12:00:00 AM		Permit Finaled	09/30/2016 12:00:00 AM	ADDRESS	34.04275	-118.25596	Plan check for Title 24 only. Project site is an existing retail space within a commercial building. Project scope is a tenant improvement. Total lighting area = 1,635 sq. ft.Note: Building permit has been pulled under 16016-10000-10380	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77671	18041-10000-01696	1027 W MANCHESTER AVE	90044	8	097-5A199 230	6033026021	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southwest Area		2382.00	Electrical	Electrical	Commercial			01/16/2018 12:00:00 AM	03/27/2018 12:00:00 AM		Permit Closed	03/20/2023 12:00:00 AM	ADDRESS	33.96019	-118.29276	T-24, PC for energy only. Plan check for lighting modification located in an existing commercial bank. total affected area is 5400 Sq. Ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77672	18041-10000-19533	21431 W DEVONSHIRE ST	91311	12	204B105   175	2722007103	P-1, [Q]C2-2D	North Valley	Chatsworth - Porter Ranch	Chatsworth		1132.12	Electrical	Electrical	Commercial			05/24/2018 12:00:00 AM	05/25/2018 12:00:00 AM		Permit Finaled	10/04/2018 12:00:00 AM	ADDRESS	34.25739	-118.59841	Replacing Existing HID Fixtures with new LED Fixtures. Title-24 Energy ONLY.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77673	10041-20000-09924	7266 W FRANKLIN AVE	90046	4	147B181    31	5548001195	R3-1	Central	Hollywood	Hollywood Hills West	YES	1899.01, 1941.00	Electrical	Electrical	Commercial			05/25/2010 12:00:00 AM	06/01/2010 12:00:00 AM		Permit Finaled	11/09/2010 12:00:00 AM	ADDRESS	34.10327	-118.3478	Lighting in apartment common area and office area. Energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77674	11041-20003-01877	330 S LA CIENEGA BLVD	90048	5	138B173   831	5511032047	C2-1VL-O, P-1VL-O	Central	Wilshire	Mid City West		2148.00	Electrical	Electrical	Commercial			11/18/2011 12:00:00 AM			PC Approved	11/18/2011 12:00:00 AM	ADDRESS	34.07282	-118.37627	Modification to an approved set of plans.  All changes are clouded.  The changes involved the lighting only (adding or relocating fixtures).	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77675	18041-20000-11651	17946 W RINALDI ST	91344	12	213B125   432	2715018043	RE11-1	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/30/2018 12:00:00 AM	03/30/2018 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.27911	-118.52518	Plan check for a PV1 roof-mounted PV system. System size is 3 kWdc/2.3 kWac and consists of (10) modules and (10) micro-inverters. Standard plan is not being used.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77676	12041-20000-04153	11395 N BRADLEY AVE	91331	7	210B157     8	2523004031	M1-1, M2-1	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			02/23/2012 12:00:00 AM	02/23/2012 12:00:00 AM		Permit Finaled	07/23/2012 12:00:00 AM	ADDRESS	34.27664	-118.42675	energy plan check bathrooms	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77677	13041-20000-26882	8505 W FOOTHILL BLVD	91040	7	207B189  1077	2555033031	C2-1VL	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga		1032.00	Electrical	Electrical	Commercial			09/27/2013 12:00:00 AM			PC Approved	09/27/2013 12:00:00 AM	ADDRESS	34.25989	-118.31823	T24 FOR EXISTING OUTDOOR CANOPY FOR GAS STATION. MOUNTING ABOVE GRADE LEVEL PER APPLICANT. RETROFITTING LIGHTS AND RECONNECTING TO EXISTING CIRCUIT AND TIMECLOCK.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77678	11041-10000-25775	6300 W WILSHIRE BLVD 1ST FLOOR	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			12/02/2011 12:00:00 AM	04/18/2012 12:00:00 AM		Permit Finaled	07/10/2012 12:00:00 AM	ADDRESS	34.06319	-118.36591	T. I.  for bank space, full P/check by applicant's request.(NON BEARING INTERIOR TI  +/- 4820 SF ;  STRUCTURAL WORK: OVERHEAD DOOR AND ATM WALL OPENING; CHANGE OF USE FROM OFFICE TO BANK)	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77679	15041-10000-26373	12800 W CULVER BLVD	90066	11	105B157   410	4221031014	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			08/13/2015 12:00:00 AM	08/13/2015 12:00:00 AM		Permit Finaled	02/25/2016 12:00:00 AM	ADDRESS	33.98489	-118.42552	REPLACE UPS LIKE FOR LIKE.  PLAN CHECK FOR POWER REQUESTED BY APPLICANT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77680	11041-10000-03724	4929 W WILSHIRE BLVD STE. 650	90010	4	135B185   568	5507018032	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2110.00	Electrical	Electrical	Commercial			02/28/2011 12:00:00 AM	02/28/2011 12:00:00 AM		Permit Finaled	05/05/2011 12:00:00 AM	ADDRESS	34.06228	-118.33794	T.I. ON EXISTING HIGH RISE OFFICE BUILDING.  TITLE-24 ONLY, OVER THE COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77681	17041-10000-23247	809 S HILL ST	90014	14	127-5A209  75	5144018029	C5-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			07/18/2017 12:00:00 AM	10/10/2017 12:00:00 AM		Permit Finaled	05/11/2018 12:00:00 AM	ADDRESS	34.04431	-118.2562	Plan check for power and Title 24.  T.I. to existing restaurant.  Two new subpanels with lighting, receptacles, and HVAC.  New connected load > 400 amps.  Lighting area = 2,630 sq. ft.       Building permit #17016-10000-17926	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77682	15041-30001-39697	20530 W WYANDOTTE ST	91306	3	186B109   951	2113022011	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Winnetka		1347.10	Electrical	Electrical	1 or 2 Family Dwelling			11/24/2015 12:00:00 AM			PC Approved	01/07/2016 12:00:00 AM	ADDRESS	34.20299	-118.58108	Expedite fees only.     Installation of new roof mounted solar PV array on existing single family dwelling.  Interconnect new inverter and modules with existing PV system.  Total system size = 6.7 kWac (3 kWac new).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77683	19041-20000-22638	1633 N LA BREA AVE	90028	4	147B181  1177	5548008***	C4-1VL-SN, R4-1VL	Central	Hollywood	Hollywood Hills West		1899.04	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM			PC Info Complete	06/18/2019 12:00:00 AM	ADDRESS	34.10068	-118.34528	T24 PLAN CHECK FOR LIGHTS AND OUTLETS ONLY IN EXISTING HIGH RISE COMMERCIAL. TI OF LOBBY AND ROOF DECK ON 6TH AND 7TH FLOOR. TOTAL SQUARE FOOTAGE = 4855 SF	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77684	13041-10000-23477	20454 W ROBERT PL	91364	3	168A111    29	2174017015	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center	YES	1375.04	Electrical	Electrical	1 or 2 Family Dwelling			08/28/2013 12:00:00 AM	01/09/2014 12:00:00 AM		Permit Finaled	02/26/2014 12:00:00 AM	ADDRESS	34.15631	-118.57906	PV1.  Install 9.00 kW DC roof-mounted solar array, interconnect with main service panel.  Solar PV Standard Electrical Plan	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77685	19041-10000-05328	14565 W LANARK ST	91402	6	189B149    17	2210011030	[Q]M1-1-CDO	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.20	Electrical	Electrical	Commercial			02/14/2019 12:00:00 AM	02/14/2019 12:00:00 AM		Permit Finaled	05/07/2019 12:00:00 AM	ADDRESS	34.21805	-118.45109	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T/24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77686	17041-20000-08708	12444 W CHANDLER BLVD	91607	2	171B165   144	2347031029	[Q]C2-1VL	South Valley	North Hollywood - Valley Village	Valley Village		1249.03	Electrical	Electrical	Apartment			03/17/2017 12:00:00 AM			PC Info Complete	04/04/2017 12:00:00 AM	ADDRESS	34.16819	-118.40448	277 device fire alarm system with FACP for a new 5 story apartment building with 2 levels subterranean parking.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77687	16041-10000-10127	5161 N LANKERSHIM BLVD #220	91601	2	171B173   677	2353004040	C4-2D-CA	South Valley	North Hollywood - Valley Village	Mid-Town North Hollywood		1254.01	Electrical	Electrical	Commercial			03/23/2016 12:00:00 AM			PC Info Complete	03/23/2016 12:00:00 AM	ADDRESS	34.16452	-118.37469	T-24, PC FOR ENERGY ONLY. MINOR TI FOR AN EXISTING COMMERCIAL BUILDING AT SUITE 220. SCOPE INCLUDES NEW CONTROLS FOR LIGHTING FIXTURES AND NEW RECEPTACLES FOR OFFICE SPACES. ALL LIGHTING FIXTURES ARE EXISTING TO REMAIN. TOTAL AFFECTED AREA IS 1261 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77688	19041-20000-07024	9325 N RESEDA BLVD	91324	12	198B125   187	2763004045	C4-1VL, P-1VL	North Valley	Northridge	Northridge West		1152.01	Electrical	Electrical	Commercial			02/26/2019 12:00:00 AM	12/09/2022 12:00:00 AM		Issued	12/09/2022 12:00:00 AM	ADDRESS	34.23978	-118.5364	PV3PV PLAN CHECK FOR INSTALLING A NEW CARPORT MOUNTED PV SYSTEM SIZED 142.56 KW DC/129.6 KW AC. SCOPE OF WORK CONSISTS OF (264) PV MODULES WITH OPTIMIZERS AND (3) INVERTERS AND A PANEL	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77689	13041-10000-24742	2506 1/2 S RAYMOND AVE	90007	8	123B197   748	5054017004	R2-1-HPOZ	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2216.01	Electrical	Electrical	Commercial			09/10/2013 12:00:00 AM	03/25/2014 12:00:00 AM		Permit Finaled	04/02/2014 12:00:00 AM	ADDRESS	34.0335	-118.2974	PV1. INSTALL 2.94 KW DC ROOF MOUNTED SOLAR ARRAY OF 12 MODULES. INTERCONNECT WITH MAIN SERVICE PANEL.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77690	11041-10000-00340	701-705 N SAN LORENZO ST	90402	11	126B133   315	4408030017	R1-1	West Los Angeles	Brentwood - Pacific Palisades		YES	2628.00	Electrical	Electrical	1 or 2 Family Dwelling			01/07/2011 12:00:00 AM	04/20/2011 12:00:00 AM		Permit Finaled	04/26/2013 12:00:00 AM	ADDRESS	34.03798	-118.50993	NEW SFD	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77691	14041-10000-30465	8704 S SEPULVEDA BLVD	90045	11	096B165   736	4123002002	[Q]C2-2D-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			11/03/2014 12:00:00 AM			Reviewed by Supervisor	11/14/2014 12:00:00 AM	ADDRESS	33.95857	-118.39595	Plan check for power and energy. TI to existing commercial space (Staples store). Indoor lighting area = 14,902 sq. ft. Outdoor lighting area = 906 sq. ft. Relocation of luminaires, (2) panel boards, and branch circuits.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77692	15041-10000-24735	2510 W TEMPLE ST	90026	13	138A205   217	5157008013	C2-1	Central	Westlake	Greater Echo Park Elysian		2085.01	Electrical	Electrical	Apartment			07/31/2015 12:00:00 AM	10/29/2015 12:00:00 AM		Permit Finaled	05/01/2017 12:00:00 AM	ADDRESS	34.07192	-118.27348	Full plan check for a  mixed use 47-unit apartment building located in a METHANE BUFFER ZONE with a groud floor parking and retails. Scope includes an 800-Amp 3-phase 4-wires 120/208V service; Total (51) panels with 6-TYPICAL UNIT, 705-circuits, 101-equipment and 18820-SQ feet for T24.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77693	10041-10000-01116	1822 W 3RD ST	90057	1	133-5A205  66	5154022008	C2-1	Central	Westlake		YES	2089.04	Electrical	Electrical	Commercial			01/21/2010 12:00:00 AM	06/16/2010 12:00:00 AM		Permit Finaled	03/13/2012 12:00:00 AM	ADDRESS	34.06138	-118.26977	New coin laundry.  Power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77694	19041-20000-12007	333 S HOPE ST 40TH FLR-STE 4050	90071	14	130-5A211   2	5151014031	C4-4D	Central	Central City	Downtown Los Angeles	YES	2075.02	Electrical	Electrical	Commercial			04/03/2019 12:00:00 AM			PC Approved	04/03/2019 12:00:00 AM	ADDRESS	34.05326	-118.25292	TI to (E) commercial office space in highrise building.  Plan check for energy.Building permit under 19016-10000-06931	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77695	11041-20000-21291	6039 N DE SOTO AVE	91367	3	177B105    63	2149005032	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hill	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			10/05/2011 12:00:00 AM			PC Approved	10/05/2011 12:00:00 AM	ADDRESS	34.18005	-118.5908	Offices and restrooms t.i.Energy only	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77696	11041-10000-19671	6415 W ROMAINE ST	90038	13	144B185   949	5533014011	R3-1	Central	Hollywood	Central Hollywood		1918.10	Electrical	Electrical	Public Safety Only			09/15/2011 12:00:00 AM			PC Approved	09/15/2011 12:00:00 AM	ADDRESS	34.08902	-118.33049	Fire alarm system for care home.  See existing permit 11041-90000-08381.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77697	18041-10000-18492	7658 N HASKELL AVE	91406	6	186B141    21	2206012014	CM-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1274.00	Electrical	Electrical	Commercial			05/17/2018 12:00:00 AM	05/18/2018 12:00:00 AM		Permit Finaled	06/25/2018 12:00:00 AM	ADDRESS	34.20995	-118.47475	REPLACE OUTDOOR EXISTING FIXTURES WITH LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77698	12041-20000-18074	1030 S ROBERTSON BLVD	90035	5	132B169   296	4332016042	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			08/02/2012 12:00:00 AM			Reviewed by Supervisor	09/11/2012 12:00:00 AM	ADDRESS	34.0582	-118.38345	New  roof and wall mounted P.V. with 29KWdc	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77699	13041-20000-17773	1140 E 58TH ST	90011	9	108B209  1373	5104031012	MR1-1	South Los Angeles	Southeast Los Angeles	Central Alameda		2291.00	Electrical	Electrical	Commercial			07/05/2013 12:00:00 AM			PC Approved	07/05/2013 12:00:00 AM	ADDRESS	33.99007	-118.25531	CHANGE OUT FIXTURES IN WAREHOUSE FOR ENERGY EFFICIENT FLOURESCENT. TOTAL OF 20 FIXTURES WITH INTERGRATED OCCUPANCY SENSORS. PC FOR T24 ENERGY ONLY. TOTAL AREA 7700 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77700	14041-10001-03883	947 W STATLER ST	90731	15	024B197    57	7442003010	R1-1XL	Harbor	San Pedro	Northwest San Pedro		2951.03	Electrical	Electrical	1 or 2 Family Dwelling			02/11/2014 12:00:00 AM			PC Approved	04/03/2014 12:00:00 AM	ADDRESS	33.76399	-118.29913	EXPEDITED RSES PLAN CHECK PER APPLICANT REQUEST.{{PV1, Install 4 kW DC roof-mounted solar array on a two-story home, interconnect with service panel. (1)Transformerless inverter: Solaredge SE 3800A-US. (16) Modules: CANADIAN SOLAR CS6P-250PX.}}	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77701	17041-10000-43150	4553 S GLENCOE AVE 300	90292	11	105B153   113	4212007011	[Q]M1-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2753.02	Electrical	Electrical	Commercial			11/30/2017 12:00:00 AM			PC Info Complete	12/06/2017 12:00:00 AM	ADDRESS	33.98415	-118.43328	Energy plan check for an office T.I. located in a (3 ) storry building. Scope includes new lighting and receptacle. Total area is 3301 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77702	12041-10000-09681	859 S SANTEE ST	90014	14	126A211   161	5145013020	M2-2D	Central	Central City	Downtown Los Angeles		2260.02	Electrical	Electrical	Commercial			04/27/2012 12:00:00 AM			PC Info Complete	04/27/2012 12:00:00 AM	ADDRESS	34.04036	-118.25321	TI IN AN EXISTING RESTAURANT  (OR NEW?). PLAN CHECK FOR T-24 ENERGY CALCS ONLY.  <COMPLETE PLAN CHECK MAY BE REQUIRED SUBJECT TO FIELD INSPECTION.>	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77703	18041-10000-02451	6340 N VARIEL AVE	91367	3	180B105    69	2149003009	(WC)COLLEGE-SN	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1349.05	Electrical	Electrical	Commercial			01/23/2018 12:00:00 AM	01/23/2018 12:00:00 AM		Issued	01/23/2018 12:00:00 AM	ADDRESS	34.18624	-118.59256	REPLACE OUTDOOR METAL  HALIDE FIXTURES WITH NEW LED FIXTURES. T-24 ONLY	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77704	16041-10000-12392	1142 S WESTWOOD BLVD	90024	5	132B153   246	4363022009	C4-2D-O	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Commercial			04/08/2016 12:00:00 AM	04/08/2016 12:00:00 AM		Permit Finaled	06/15/2016 12:00:00 AM	ADDRESS	34.05997	-118.44467	Title 24 plan check only.  Total area = 921 sq. ft.     T.I. to existing commercial retail space.  Subpanels to remain existing.  New lighting, inverter, and receptacles.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77705	16041-20000-37425	4224 N LOUISE AVE	91316	5	165B133   351	2292002027	RA-1	South Valley	Encino - Tarzana	Encino	YES	1397.02	Electrical	Electrical	1 or 2 Family Dwelling			10/21/2016 12:00:00 AM	11/01/2016 12:00:00 AM		Permit Finaled	02/09/2017 12:00:00 AM	ADDRESS	34.14783	-118.50602	Plan check for a PV1 roof-mounted PV system. System size is 19.6 kWac and consists of (70) micro-inverters, (70) modules, and (1) load center.$0 permit fee due to State Senate Bill SB 1222	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77706	15041-20000-22582	19929 W SEPTO ST	91311	12	201B113    40	2726003026	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2015 12:00:00 AM	07/16/2015 12:00:00 AM		Permit Finaled	07/22/2015 12:00:00 AM	ADDRESS	34.25105	-118.56788	Installation of new roof mounted solar PV array.  Total system size = 6 kWac.  Central inverter system (standard plan).	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77707	18041-20000-08184	10250 W CONSTELLATION BLVD Floors 24-25	90067	5	132B161   717	4319004140	C2-1VL-O, C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/06/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.05735	-118.41746	TI to (E) commercial highrise building office.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77708	13041-20001-29306	8621 S RAMSGATE AVE	90045	11	096B169   642	4125013003	R3-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2772.00	Electrical	Electrical	Commercial			08/12/2014 12:00:00 AM			PC Approved	08/14/2014 12:00:00 AM	ADDRESS	33.95917	-118.38282	CHANGES TO APPROVED SET OF PLANS. PLAN CHECK ONLY FOR CHANGES MADE: CHANGE ON SINGLE LINE FROM COPPER CONDUCTORS TO ALUMINUM CONDUCTORS, CHANGE IN SERVICE LOCATION FROM INDOOR TO OUTDOOR, CHANGE IN SHORT CIRCUIT PROTECTION FROM FULLY RATED TO SERIES RATED AS NOTED ON PLANS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77709	16041-10002-30763	1220 N NORTH SPRING ST	90012	1	135A217    30	5409006030	UI(CA)	Central	Central City North	Historic Cultural		2060.10	Electrical	Electrical	Commercial			08/03/2017 12:00:00 AM	08/15/2017 12:00:00 AM		Permit Finaled	06/04/2018 12:00:00 AM	ADDRESS	34.06577	-118.23347	08/03/17Changes to an approved set of plans. All changes are made under delta 3. Changes include adding a new 800A service, revising panel schedules, and revising electrical room on floor plans.Note: Some permit fees will be paid under master application PCIS#16041-10000-30763	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77710	12041-20000-28340	2075 N LINDA FLORA DR	90077	5	150B145    56	4377002034	RE40-1-H	West Los Angeles	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2012 12:00:00 AM	12/19/2012 12:00:00 AM		Permit Finaled	12/24/2012 12:00:00 AM	ADDRESS	34.10854	-118.46603	PV-1. Plan check for PV system.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77711	17041-20000-22610	6140 N FENWOOD AVE	91367	3	177B093   438	2035023025	RA-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1352.02	Electrical	Electrical	1 or 2 Family Dwelling			07/06/2017 12:00:00 AM	07/06/2017 12:00:00 AM		Permit Finaled	07/17/2017 12:00:00 AM	ADDRESS	34.18188	-118.63386	PV1.  Install 7.68 kW roof mounted grid tied PV system.  ACM standard plan.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77712	17041-20000-45762	14101 W PIERCE ST	91331	6	201B153   465	2644005032	RS-1	North Valley	Arleta - Pacoima	Arleta		1192.01	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2017 12:00:00 AM	01/04/2018 12:00:00 AM		Permit Finaled	10/16/2018 12:00:00 AM	ADDRESS	34.24748	-118.44057	pv1install roof mounted pv system sized 6.6kw with battery back up interconnected with msp.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77713	11041-10003-15811	700 S SANTA FE AVE	90021	14	124-5A217 273	5166002011	M3-1	Central	Central City North	Downtown Los Angeles		2060.50	Electrical	Electrical	Commercial			01/23/2012 12:00:00 AM	01/23/2012 12:00:00 AM		Permit Finaled	01/26/2012 12:00:00 AM	ADDRESS	34.03435	-118.22981	ADDED SUBPANEL A1 ; redistributre loads on panelA; revised lighting load sand adjusted compliance forms for energy complianceUPGRADE SERVICE TO 600A AND MADE CHANGES TO LIGHTING SYSTEM; PERMIT HAVE BEEN OBTAINED FOR THE CIRCUITSthis is additional permit for additional ckts and equipment. title 24 approved under 11041-20000-15811 TAKE-OUT BAKERY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77714	11041-10000-26686	7542 S MIDFIELD AVE	90045	11	099B173   200	4127002014	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2771.00	Electrical	Electrical	1 or 2 Family Dwelling			12/14/2011 12:00:00 AM	02/27/2012 12:00:00 AM		Permit Finaled	06/08/2012 12:00:00 AM	ADDRESS	33.96893	-118.37435	9.2KW ROOF MOUNTED PHOTOVOLTAIC SYSTEM SINGLE FAMILY DWELLING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77715	19041-20000-47942	12359 W SARAH ST	91604	2	168B165   891	2364009033	R1-1-RIO	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1434.00	Electrical	Electrical	1 or 2 Family Dwelling			11/20/2019 12:00:00 AM	11/20/2019 12:00:00 AM		Permit Finaled	01/06/2020 12:00:00 AM	ADDRESS	34.1541	-118.40291	PV1 PLAN CHECK FOR NEW ROOF PV SYSTEM. SYSTEM SIZE IS 8.8 KW DC/7.68 KW AC. SCOPE OF WORK CONSISTS OF (22) PV MODULES WITH INTEGRATED MICROINVERTERS, AND A NEW SOLAR LOAD CENTER	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77716	16041-10001-13191	1411 W 190TH ST #455	90248	15	060B193   374	7351001019	M2-1	Harbor	Harbor Gateway	Harbor Gateway South		2920.00	Electrical	Electrical	Commercial			04/19/2016 12:00:00 AM			PC Approved	04/25/2016 12:00:00 AM	ADDRESS	33.85852	-118.30317	permit already issued under master. this application is for plan check only for T24.REMODEL. TENANT IMPROVEMENT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77717	15041-20001-39313	4530 W BRAZIL ST 1-5	90039	13	165B205    88	5593011034	M3-1-RIO	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			11/20/2015 12:00:00 AM			PC Approved	12/09/2015 12:00:00 AM	ADDRESS	34.14653	-118.27344	**Fee Expedite***Install a roof-mounted solar array on a commercial building. Interconnect with a 1600A MSP.System size: 140kW (7 - 20kW inverters). Ungrounded system. Using 700W power optimizers. Each optimizer has 2 pv modules connected to it. (484) 310W pv modules.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77718	16041-10000-14268	15760 W VENTURA BLVD #1100	91436	5	168B141   657	2283025015	C4-1L	South Valley	Encino - Tarzana	Encino		1414.00	Electrical	Electrical	Commercial			04/25/2016 12:00:00 AM	04/25/2016 12:00:00 AM		Permit Finaled	07/27/2016 12:00:00 AM	ADDRESS	34.1552	-118.47684	T-24, PC FOR ENERGY ONLY. TI TO ON A EXISTING HIGH RISE COMMERCIAL BUILDING ON THE 11 FLOOR. SCOPE INCLUDES NEW LIGHTS AND RECEPTACLES FOR AN OFFICE SPACE ON THE 11 FLOOR. TOTAL AFFECTED AREA IS 4626 SQ. FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77719	14041-10000-18601	10777 W WILSHIRE BLVD 1-56	90024	5	132B153   173	4360004012	[Q]R5-3	West Los Angeles	Westwood	Westwood		2652.02	Electrical	Electrical	Apartment			07/18/2014 12:00:00 AM	09/04/2015 12:00:00 AM		Permit Finaled	01/22/2019 12:00:00 AM	ADDRESS	34.06038	-118.43901	PC FOR  POWER AND ENERGY. New 56-unit, 5-story Type IIIA over 2-story Type IA residential/parking with 2 levels of subterrean parking garage. (100% submittal/PDPP>PERMIT IS GOING TO BE UNDER NEC 2008 AND CEC 2008.BUILDING APP#; 13010-10000-03895.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77720	11041-10000-25973	1250 W HARRY BRIDGES BLVD	90744	15	027B205   473	7440007***	[Q]M3-1	Harbor	Port of Los Angeles	Wilmington		2949.00	Electrical	Electrical	Commercial			12/06/2011 12:00:00 AM	04/26/2013 12:00:00 AM		Permit Closed	01/21/2015 12:00:00 AM	PIN	33.77046453	-118.27163726	LEVEL V METHANE  MITIGATION SYSTEM FOR AT ELECT/EQUIP BUILDING FOR MAIN GATE CANOPY	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77721	15041-10000-35908	600 S NEW HAMPSHIRE AVE 2ND FLOOR	90005	10	135B197  1009	5502025021	C2-2	Central	Wilshire	Wilshire Center - Koreatown		2121.01	Electrical	Electrical	Commercial			10/27/2015 12:00:00 AM	12/07/2015 12:00:00 AM		Permit Finaled	05/16/2016 12:00:00 AM	ADDRESS	34.06344	-118.29276	T-24, CHANGE OF USE FROM RESTAURANT TO A BEAUTY SALON, SCOPE INCLUDES NEW LIGHTING AND RECEPTACLES. TOTAL SQ. FT. 2865	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77722	15041-10000-08300	13421 N BORDEN AVE	91342	7	225B149   113	2502030002	RA-1-K	North Valley	Sylmar	Sylmar		1064.06	Electrical	Electrical	1 or 2 Family Dwelling			03/20/2015 12:00:00 AM	11/06/2015 12:00:00 AM		Permit Finaled	03/02/2016 12:00:00 AM	ADDRESS	34.31597	-118.45449	PV1 6.0KW roof-mounted system with (21) Sunpower SPR-327 modules and (1) SMA America SB 6000TL inverter interconnecting through a subpanel.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77723	14041-20000-10082	8926 W RIDERWOOD DR	91040	7	207B189   373	2547028023	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tujunga	Sunland - Tujunga	YES	1032.00	Electrical	Electrical	1 or 2 Family Dwelling			04/16/2014 12:00:00 AM			Reviewed by Supervisor	05/02/2014 12:00:00 AM	ADDRESS	34.26541	-118.32644	PV1.  Install 8.25 kW roof-mounted PV system, interconnect with main service panel. (33) modules.  Central inverter: SMA America SB7000US	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77724	12041-10000-19752	1006 S OLIVE ST	90015	9	127-5A209 257	5139012014	[Q]R5-4D-O	Central	Central City	Downtown Los Angeles		2079.00	Electrical	Electrical	Commercial			08/22/2012 12:00:00 AM	08/24/2012 12:00:00 AM		Permit Finaled	11/05/2012 12:00:00 AM	ADDRESS	34.04195	-118.25959	CONVERT 815 SF PORTION OF (E) RETAIL/ OFFICE TO THE SAME USE &HAIR SALON.  Load is less thabn 400Amps.  PLAN CHECK ONLY for Energy with Emergency lighting.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77725	16041-10000-01583	1615 N BLUE JAY WAY	90069		147B169   100	5561026015							Electrical	Electrical	1 or 2 Family Dwelling			01/15/2016 12:00:00 AM			Reviewed by Supervisor	01/28/2016 12:00:00 AM	ADDRESS	34.10221	-118.38672	PC FOR POWER ONLY, NEW SUNGLE FAMILY DWELLING WITH ATTACHED GARAGE. 800 AMP SERVICE	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77726	13041-10000-24161	5700 N CANOGA AVE 3RD FLOOR	91367	3	174B105    83	2149019015	WC	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1371.04	Electrical	Electrical	Commercial			09/05/2013 12:00:00 AM			Corrections Issued	09/05/2013 12:00:00 AM	ADDRESS	34.17365	-118.59715	TITLE 24 PLAN CHECK ONLY. 5 STORY BUILDING. WORK ON 3RD FLOOR. 8716 SQFT. EMERGENCY LIGHTING. PERMIT TO BE PULLED AT ELECTRICAL PLAN CHECK COUNTER.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77727	17041-10000-45907	200 N SPRING ST	90012	14	130-5A213   1	5161005906	OS-2D, PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			07/30/2018 12:00:00 AM	10/09/2018 12:00:00 AM		Permit Finaled	08/02/2019 12:00:00 AM	ADDRESS	34.05405	-118.24317	PC FOR POWER FOR A NEW EV CHARGING STATION IN EXISTING PARKING STRUCTRE. SCOPE INCLUDES TAPPING EXISTING SERVICE AND INSTALLING NEW DEDICATED EV DIST. BOARD (600A 480/277V)AND  PANELS INCLUDING EV EQUIPMENT. PROJECT COVERS INSTALLATION ON FLOORS  UL,LL (UPPER LEVEL &LOWER LEVEL)*PE INFORMATION NEEDED AT TIME OF SUMBITTAL.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77728	14041-20000-18918	16921 W LANARK ST	91406	6	189B133    75	2204031016	R1-1	South Valley	Reseda - West Van Nuys	Lake Balboa		1311.00	Electrical	Electrical	1 or 2 Family Dwelling			07/15/2014 12:00:00 AM	07/15/2014 12:00:00 AM		Permit Finaled	07/24/2014 12:00:00 AM	ADDRESS	34.2181	-118.50193	PV1Central/String inverter standard plan.Install roof-mounted solar array on SFD. System size: 5kW.(1) SolarEdge SE5000A-US-ZB-U transformerless inverter(24) SolarEdge P300 power optimizers(24) Trina Solar TSM-255 pv modules	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77729	19041-10000-37771	2365 E CENTURY BLVD	90002	15	093A217   270	6046019***	CM(UV)	South Los Angeles	Southeast Los Angeles	Watts		2421.00	Electrical	Electrical	Commercial			09/20/2019 12:00:00 AM	10/30/2019 12:00:00 AM		Permit Finaled	04/14/2020 12:00:00 AM	ADDRESS	33.94668	-118.2305	Power PC for 5-EV charges (2 @ LVL 3) and (3 @ LVL 2) EV charges.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77730	16041-10000-17846	17331 W DEARBORN ST	91325	12	198B129   352	2766012003	RA-1	North Valley	Northridge	Northridge East		1151.01	Electrical	Electrical	1 or 2 Family Dwelling			05/20/2016 12:00:00 AM	05/20/2016 12:00:00 AM		Permit Finaled	06/14/2016 12:00:00 AM	ADDRESS	34.23724	-118.5127	PV1. NEW SOLAR SYSTEM ON EXISTING RESIDENTIAL ROOF-TOP. TOTAL SYSTEM SIZE IS 12.0KWac.(40)MODULES-SUNPOWER SPR 2E20(2)INVERTERS-SMA 6000INTERCONNECTING THROUGH THE MAIN SERVICE PANEL.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77731	18041-20000-40037	5670 W WILSHIRE BLVD ste 600	90036	4	135B181   929	5089007021	[Q]C4-2-CDO	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			10/19/2018 12:00:00 AM	10/19/2018 12:00:00 AM		Permit Finaled	01/31/2019 12:00:00 AM	ADDRESS	34.06222	-118.35208	ti to an existing commercial building (high rise) adding new lighting new controls to existing panels.  plan check for indoor energy only.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77732	16041-10001-24032	14319 W GREENLEAF ST	91423	4	165B153   585	2266005025	RE11-1	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1412.02	Electrical	Electrical	1 or 2 Family Dwelling			07/08/2016 12:00:00 AM			PC Approved	08/18/2016 12:00:00 AM	ADDRESS	34.14778	-118.44542	EXPEDITION FEE.<<<PV1 INSTALL 21.7 KW D C ROO-MOUNTED SOLAR ARRAY ON A SINGLE FAMILY HOUSE.(70)MODULES; WINAICO WSP310-M6(2) INVERTERS : SOLAREDGE 7.6 AND 11.4 KW>>>	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77733	18041-10000-14530	11537 N BRADLEY AVE	91340	7	213B157   496	2523002003	M1-1-CUGU, M2-1-CUGU	North Valley	Arleta - Pacoima	Pacoima		1043.10	Electrical	Electrical	Commercial			04/19/2018 12:00:00 AM	04/20/2018 12:00:00 AM		Permit Finaled	05/15/2018 12:00:00 AM	ADDRESS	34.27941	-118.42959	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES. T-24 ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77734	16041-30000-25330	3831 S HUGHES AVE 6th Floor	90232	5	120B165  1229	4207004024	CR-1	West Los Angeles	Palms - Mar Vista - Del Rey	Palms		2699.05	Electrical	Electrical	Commercial			07/19/2016 12:00:00 AM			PC Approved	07/19/2016 12:00:00 AM	ADDRESS	34.02242	-118.39823	Plan check for Title 24 only. Project site is the 6th floor of an existing commercial building. Project scope is a tenant improvement. Total lighting area = 1,540 sq. ft.Note: Building application has been generated under 16016-10000-12414	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77735	16041-10000-01569	2049 S CENTURY PARK EAST # S850	90067	5	132B161   698	4319016030	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			01/15/2016 12:00:00 AM	01/19/2016 12:00:00 AM		Permit Finaled	05/03/2016 12:00:00 AM	ADDRESS	34.05903	-118.41293	PC FOR ENERGY. T24 ONLY.  TI FOR  LAW OFFICE.  HIGH RISE BUILDING.TOTAL AREA 3695 SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77736	15041-10002-09642	15474 W DUOMO VIA	90077	5	156B145   197	4378036019	RE40-1-H	South Valley	Bel Air - Beverly Crest	Bel Air - Beverly Crest	YES	2622.00	Electrical	Electrical	1 or 2 Family Dwelling			05/14/2015 12:00:00 AM			PC Approved	05/14/2015 12:00:00 AM	ADDRESS	34.12386	-118.47023	Changes to an approved set of plans. Changes include the change of the main service panel OCPD to reflect what is on the field, and the rating of the PV subpanel. All changes have been marked and clouded.*****Previous Work Description*****PV1 9.03KW roof-mounted  microinverter system with (42) SW-270 Mono solar modules, (42) Enphse M215-IG interconnecting through a new solar load center.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77737	11041-20000-15468	11611 W SAN VICENTE BLVD #910	90049	11	132B145   482	4401019001	C1.5-1VL	West Los Angeles	Brentwood - Pacific Palisades			2641.01	Electrical	Electrical	Commercial			07/25/2011 12:00:00 AM	07/25/2011 12:00:00 AM		Permit Finaled	08/30/2011 12:00:00 AM	ADDRESS	34.0541	-118.46261	Plan check T24 Energy (general/emergency) lighting for office TI suite #910. Permit for new devices on existing ckts.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77738	17041-10001-25123	5412 W MONROE ST	90038	13	141B193   250	5535013011	R2-1XL	Central	Hollywood	Hollywood Studio District		1917.10	Electrical	Electrical	1 or 2 Family Dwelling			01/03/2018 12:00:00 AM			PC Approved	01/03/2018 12:00:00 AM	ADDRESS	34.08565	-118.31181	PC for revisions to approved set. Adding fuse to AC disconnect with change clouded.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77739	17041-10000-04847	7939 N NORWICH AVE	91402	6	189B145   409	2209022008	R1-1	North Valley	Mission Hills - Panorama City - North Hills	Panorama City		1200.10	Electrical	Electrical	1 or 2 Family Dwelling			02/14/2017 12:00:00 AM	02/15/2017 12:00:00 AM		Permit Finaled	08/16/2017 12:00:00 AM	ADDRESS	34.21539	-118.46122	roof mountedPC FOR 10KW AC USING CENTRAL INVERTER SYSTEM AND TOTAL OF 42 MODULES.	N	Y	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77740	16041-20000-04530	1030 W PACIFIC COAST HWY	90710	15	033B197     2	7411020040	[Q]C1-1L	Harbor	Wilmington - Harbor City	Harbor City		2944.21	Electrical	Electrical	Commercial			02/09/2016 12:00:00 AM			PC Approved	02/09/2016 12:00:00 AM	ADDRESS	33.79073	-118.29408	Plan check for Title 24 only. Project site is an existing commercial building. Project scope is outdoor lighting. Total lighting area = 1,615 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77741	17041-10000-25476	3250 N GLENDALE BLVD	90039	13	153B209   189	5436024006	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1871.01	Electrical	Electrical	Commercial			07/27/2017 12:00:00 AM	07/27/2017 12:00:00 AM		Issued	07/27/2017 12:00:00 AM	ADDRESS	34.1182	-118.26022	Lighting luminaires at Levels 1&2 of a Wells Fargo bank are change out to LED luminires using retrofit kits. Lighting  controls remain the same. Exit signs remain the same plan chk is for Title 24	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77742	17041-10000-23273	8500 W BEVERLY BLVD #101	90048	5	138B173   436	4334007008	C2-1, C2-1-O	Central	Wilshire	Mid City West		2149.02	Electrical	Electrical	Commercial			07/11/2017 12:00:00 AM	08/03/2017 12:00:00 AM		Permit Finaled	12/20/2017 12:00:00 AM	ADDRESS	34.07587	-118.37754	PC FOR T24 ENERGY ONLY. TI TO RESTAURANT. UPGRADED LIGHTING. PC FOR T24 ENERGY ONLY.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77743	19041-20000-27235	17223 W DONMETZ ST pv1	91344	12	210B133   289	2697010003	RS-1	North Valley	Granada Hills - Knollwood	Granada Hills South		1112.01	Electrical	Electrical	1 or 2 Family Dwelling			07/16/2019 12:00:00 AM	07/16/2019 12:00:00 AM		Permit Finaled	08/05/2019 12:00:00 AM	ADDRESS	34.27393	-118.50854	pv1install roof mounted pv system sized 9.3KW AC interconnected with msp.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77744	12041-20003-23712	7080 W HOLLYWOOD BLVD #200	90028	13	147B181   209	5548007014	C4-2D-SN	Central	Hollywood	Central Hollywood		1901.00	Electrical	Electrical	Commercial			05/16/2013 12:00:00 AM			PC Approved	05/17/2013 12:00:00 AM	ADDRESS	34.10134	-118.34445	((More modifications to emergency lights in highrise building. Scope of work on second floor.))Modifications to emergency lighting system for highrise building.  Work is on the second floor.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77745	19041-10001-34361	5719 S MESMER AVE BLD 2	90230	11	105B165   424	4220014044	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey, Westchester/Playa del Rey		2756.03	Electrical	Electrical	Commercial			11/27/2019 12:00:00 AM	05/07/2020 12:00:00 AM		Permit Finaled	07/18/2022 12:00:00 AM	ADDRESS	33.98439	-118.3997	FULL PC FOR A NEW CONSTRUCTION, SCOPE INCLUDES A NEW 400A SERVICE (120/208 3P,4W) WHICH FEEDS 3 SUBPANELS AND 3 EV CHARGERS, NOTE T24 HAS BEEN APPROVED UNDER 19041-10000-34361.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77746	17041-10001-12335	929 W JEFFERSON BLVD BLDG 6-UNIT 1500	90007	9	121-5A201 201	5039020030	USC-3	South Los Angeles	South Los Angeles	Empowerment Congress North Area		2219.00	Electrical	Electrical	Commercial			09/07/2017 12:00:00 AM	09/07/2017 12:00:00 AM		Permit Finaled	09/19/2017 12:00:00 AM	ADDRESS	34.02454	-118.28542	CHANGES TO APPROVED SET OF PLANS. CHANGES NOTED DELTA 4 ON PLANS. CHANGES TO WATER HEATER. INCREASED SIZE AND FED FROM DIFFERENT PANEL.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77747	12041-10000-27568	725 S FIGUEROA ST 15th floor	90017	14	129A207    15	5144009***	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			11/15/2012 12:00:00 AM			PC Approved	11/15/2012 12:00:00 AM	ADDRESS	34.04886	-118.26071	PC FOR T24. TI TO EXISTING HIRISE CORRIDOR 2689 SF. 15TH FLOOR.OWNER BROOKFIELD PROP - 725 S. FIG~ LA	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77748	18041-10000-06973	200 N NORTH MAIN ST P4	90012	14	130-5A213   3	5161014901	PF-2D	Central	Central City	Downtown Los Angeles		2074.00	Electrical	Electrical	Commercial			02/26/2018 12:00:00 AM	03/01/2018 12:00:00 AM		Issued	03/01/2018 12:00:00 AM	ADDRESS	34.05326	-118.24219	Energy plan check for an office T.I located in a high rise building. Scope includes new lighting and equipment. Total area is 4,385-SQ FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77749	16041-20000-12673	1145 W WILSHIRE BLVD	90017	1	130-5A207  56	5143023001	CW	Central	Westlake	Downtown Los Angeles		2092.00	Electrical	Electrical	Commercial			04/12/2016 12:00:00 AM	04/12/2016 12:00:00 AM		Permit Finaled	07/19/2016 12:00:00 AM	ADDRESS	34.05306	-118.26461	PLANCHECK FOR T24 ENERGY. TENANT IMPROVEMENT FOR OFFICES.  5597 SQFT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77750	18041-10000-10259	1999 S AVENUE OF THE STARS 15th Floor	90067	5	132B161    47	4319003065	C2-2-O	West Los Angeles	West Los Angeles	Westside		2679.01	Electrical	Electrical	Commercial			03/21/2018 12:00:00 AM	04/12/2018 12:00:00 AM		Issued	04/12/2018 12:00:00 AM	ADDRESS	34.05886	-118.41642	PC FOR OFFICE TI IN A HIGH RISE ON THE 15TH FLOOR FOR TITLE 24 ENERGY ONLY.PHASE 2 IN THE NORTH CORNER.   SCOPE INCLUDES NEW LIGHTS,  RECEPTACLES AND EQUIPMENT.  TOTAL AFFECTED AREA 3900 SQ.FT.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77751	18041-10000-00713	13123 W TERRA BELLA ST	91331	7	204B161    86	2620024020	R1-1-O-CUGU	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			01/08/2018 12:00:00 AM	01/16/2018 12:00:00 AM		Permit Finaled	03/12/2018 12:00:00 AM	ADDRESS	34.25808	-118.41886	PV1, ROOF MOUNTED SOLAR SYSTEM USING A CENTRAL INVERTER WITH OPTIMIZERS. TOTAL SYSTEM SIZE IS 5KW. (21) MODULES AND (1) 5KW SOLAREDGE INVERTER.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77752	15041-20000-10890	1183 S CRENSHAW BLVD	90019	10	129B189   574	5082025003	R3-1-O	Central	Wilshire	Olympic Park		2128.00	Electrical	Electrical	Apartment			04/13/2015 12:00:00 AM	05/28/2015 12:00:00 AM		Permit Finaled	04/20/2016 12:00:00 AM	ADDRESS	34.05026	-118.32576	Plan check for power and Title-24 (energy).  Total area = 3,510 sq. ft. (unconditioned) + 2,810 sq. ft. (outdoor)New 8 unit 2 story apartment building with 600 A service.  Fire alarm variance has NOT been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77753	16041-20000-03513	4114 W SEA VIEW LANE	90065	1	151-5A221 308	5471001047	R1-1	East Los Angeles	Northeast Los Angeles	Arroyo Seco	YES	1851.00	Electrical	Electrical	1 or 2 Family Dwelling			02/01/2016 12:00:00 AM	02/25/2016 12:00:00 AM		Permit Finaled	04/22/2016 12:00:00 AM	ADDRESS	34.10825	-118.21542	$0 permit fee due to State Senate Bill SB-1222.Install a roof-mounted solar array on a SFD. System size: 6kW+6kW=12kW. Ungrounded system. Each module has a 400W power optimizer. (46) 345W pv modules.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77754	17041-20000-01534	4917 N TOPANGA CANYON BLVD	91364	3	168B101   442	2170011004	[Q]C1-1VL	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	Woodland Hills - Warner Center		1374.01	Electrical	Electrical	Commercial			01/17/2017 12:00:00 AM	02/07/2017 12:00:00 AM		Permit Finaled	03/10/2017 12:00:00 AM	ADDRESS	34.15734	-118.60613	Plan check for energy only. Change of use from (E) Take-Out Restaurant to (N) Hair Salon. New lighting (incl. emergency). 569sqft.=== COMPLY WITH DEPARTMENT ORDER EFFECTIVE DATE 7/18/16. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77755	18041-30000-27635	14846 W FRIAR ST	91411	6	178-5A149  14	2241008011	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Apartment			07/24/2018 12:00:00 AM	07/24/2018 12:00:00 AM		Permit Finaled	10/21/2019 12:00:00 AM	ADDRESS	34.18551	-118.45707	INSTALL NEW FIRE ALARM ON A NEW6-UNIT,  2-STORY APARTMENT BUILDING  OVER BASEMENT GARAGE. (1) PANEL, (12) DEVICES B# 16010-20000-03262	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77756	19041-20000-02080	24346 W STONE BEND LANE	91304	12	192B089   226	2017038027	RE9-1-H	North Valley	Canoga Park-West Hills-Winnetka-Woodland Hills, Chatsworth - Porter Ranch	West Hills		1344.24	Electrical	Electrical	1 or 2 Family Dwelling			01/17/2019 12:00:00 AM	01/17/2019 12:00:00 AM		Permit Finaled	03/27/2019 12:00:00 AM	ADDRESS	34.22	-118.6559	PV1.  Install 6.3 kW roof mounted grid tied PV system.  (20) modules with 7.6 kW rated string inverter.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77757	15041-10000-27728	6620 W MELROSE AVE	90036	5	141B185   611	5524017019	C2-1XL	Central	Hollywood	Greater Wilshire		1919.02	Electrical	Electrical	Commercial			08/24/2015 12:00:00 AM	10/02/2015 12:00:00 AM		Permit Finaled	12/04/2015 12:00:00 AM	PIN	34.0831925	-118.33935238	PV2.  Install 5.70 kW roof-mounted, utility-interactive PV system.  Microinverters.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77758	12041-20000-05266	10671 W LORNE ST	91352	2	189B177   205	2407012019	MR1-1	North Valley	Sun Valley - La Tuna Canyon	Sun Valley		1222.00	Electrical	Electrical	Commercial			03/08/2012 12:00:00 AM			PC Approved	03/08/2012 12:00:00 AM	ADDRESS	34.2166	-118.36373	T.I. to existing warehouse building.  Replace general/emergency lighting.  Plan check for energy only.Note: Permit issued under 12041-20000-05269	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77759	18041-20000-40663	13654 W BASSETT ST	91405	2	183B157   761	2328012003	[Q]R3-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1235.10	Electrical	Electrical	Apartment			10/24/2018 12:00:00 AM	04/16/2019 12:00:00 AM		Permit Finaled	11/12/2020 12:00:00 AM	ADDRESS	34.19567	-118.43078	New 19-unit apartment building with three stories over basement.  1200A 208/120V 3ph-4w service.  Plan check for power and energy.Building permit under 18010-20000-02536.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77760	15041-20000-18382	13075 W GARBER ST	91331	7	204B161   142	2623002022	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1046.10	Electrical	Electrical	1 or 2 Family Dwelling			06/12/2015 12:00:00 AM	06/12/2015 12:00:00 AM		Permit Finaled	07/10/2015 12:00:00 AM	ADDRESS	34.25747	-118.41789	PV1 SFD. TOTAL SYSTEM SIZE 3.4KW AC USING MICROINVERTER SYSTEM. USING TOTAL OF 16 MODULES. NONSTANDARD PLAN	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77761	19041-30000-22591	1600 N VINE ST Suite 103	90028	13	148-5A189 346	5546029***	[Q]C4-2-SN	Central	Hollywood	Central Hollywood		1910.00	Electrical	Electrical	Commercial			06/13/2019 12:00:00 AM	01/24/2020 12:00:00 AM		Permit Finaled	07/01/2021 12:00:00 AM	ADDRESS	34.1	-118.32647	Plan check for Title 24 only. Project site is an existing commercial tenant space. Project scope is a tenant improvemen to a restaurant. Total lighting area = 2,485 sq. ft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77762	18041-10000-43593	2980 W LOS FELIZ BLVD	90039	13	157-5A207 140	5435009021	[Q]C4-1XL-RIO-POD	East Los Angeles	Northeast Los Angeles	Atwater Village		1883.00	Electrical	Electrical	Commercial			11/14/2018 12:00:00 AM	11/14/2018 12:00:00 AM		Permit Finaled	02/01/2019 12:00:00 AM	ADDRESS	34.12549	-118.26436	REMOVE OUTDOOR HID FIXTURES AND REPLACE WITH NEW LED FIXTURES - T-24 ONLY	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77763	14041-10000-05939	4600 W LOS FELIZ BLVD	90027	4	150B197    58	5590004004	R3-1	Central	Hollywood	Los Feliz		1891.02	Electrical	Electrical	Apartment			03/05/2014 12:00:00 AM	03/05/2014 12:00:00 AM		Permit Finaled	03/26/2014 12:00:00 AM	ADDRESS	34.11115	-118.28953	INSTALLATION OF A NEW FIRE ALARM SYSTEM. BUILDING NOT SPRINKLERED. 1 FA PANEL AND 22 DEVICES.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77764	18041-10000-35907	11938 W PIERCE ST	91342	7	213B165   287	2531020040	RS-1	North Valley	Sunland-E LaTuna Cyn-Lakevw Ter-Shadow Hls-Tu	Foothill Trails District		1041.03	Electrical	Electrical	1 or 2 Family Dwelling			09/19/2018 12:00:00 AM	09/19/2018 12:00:00 AM		Permit Finaled	11/07/2018 12:00:00 AM	ADDRESS	34.28187	-118.393	Plan check for a 3.8KW AC / 3.64KW DC roofmounted system with (13) modules and (1) inverter interconnecting through the main service panel.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77765	16041-20001-20408	14933 W CALVERT ST	91411	6	178-5A149 315	2242024050	M2-1, M3-1	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1283.02	Electrical	Electrical	Commercial			03/02/2018 12:00:00 AM	07/09/2018 12:00:00 AM		Permit Finaled	12/06/2018 12:00:00 AM	ADDRESS	34.18132	-118.4586	SUPPLEMENTAL TO CHANGES TO APPROVED SET OF PLANS UNDER DELTA 2 - CHANGES INCLUDE ADDITION OF 4 NEW 45KVA TRANSFORMERS WITH 4 NEW PANELS - FOR MEZZANINE*****Previous Work Description*****ORIGINAL PERMIT PLANCHECK FOR POWER AND ENERGY FOR A COMMERCIAL CORE/SHELL  BUILDING ONLY WITH FIRE DAMAGE. NEW SERVICE 3000 AMPS 277/480V 3-PHASE 4-WIRE.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77766	16041-20001-31750	1750 W MARTIN LUTHER KING, JR BLVD	90062	8	114B193   333	5021032032	[Q]C2-1VL	South Los Angeles	South Los Angeles	Empowerment Congress Central Area		2315.00	Electrical	Electrical	Apartment			04/09/2019 12:00:00 AM	06/03/2019 12:00:00 AM		Permit Finaled	10/29/2019 12:00:00 AM	ADDRESS	34.01068	-118.31073	Supplemental permit to expand initial permit scope.  New house panel, (35) new unit panels in same location, relocation of receptacle outlets for ADA compliance, and AFCI circuit breakers.  Plan check for power per inspector correction notice. (((PLANCHECK FOR T24 ENERGY. TENANT IMPROVMENT FOR LIGHTING. 63000SQFT.)))	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77767	14041-20000-21023	1117 N VISTAGRANDE DR	90272	11	132B121   247	4420026019	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2626.04	Electrical	Electrical	1 or 2 Family Dwelling			08/05/2014 12:00:00 AM	08/13/2014 12:00:00 AM		Permit Finaled	08/26/2014 12:00:00 AM	ADDRESS	34.05799	-118.55052	New roof mounted PV system with total system size 9KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77768	19041-20000-47151	8514-8526 S HOOVER ST	90044	8	097-5A201 249	6032015016	[Q]C2-1	South Los Angeles	South Los Angeles	Empowerment Congress Southeast Area		2383.20	Electrical	Electrical	Commercial			11/15/2019 12:00:00 AM	07/23/2020 12:00:00 AM		Permit Finaled	05/20/2022 12:00:00 AM	ADDRESS	33.96064	-118.28689	1200A 208Y/120V 3ph-4w service, distribution, power and lighting for fueling station canopy and commercial tenant space improvements.  Plan check for power and energy.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77769	17041-20002-20920	4201 W WILSHIRE BLVD	90010	4	132B189    40	5504008009	CR(PKM)-1	Central	Wilshire	Greater Wilshire		2117.01	Electrical	Electrical	Commercial			03/15/2018 12:00:00 AM	03/15/2018 12:00:00 AM		Permit Finaled	06/29/2018 12:00:00 AM	ADDRESS	34.06189	-118.31911	03/15/2018 Changes to an approved set of plans. All changes have been clouded and marked as Delta 1. PV system size has remained the same. PV system interconnection is now being done as a load-side connection onto a new 800-amp subpanel with a 600-amp MCB. New subpanel is being fed from the secondary of a 4,160V/480V transformer.*****Previous Work Description*****PV2. ROOFMOUNTED SOLAR SYSTEM. SYSTEM SIZE: 131 KW.  INSTALLATION OF MEDIUM VOLTAGE TRANSFORMER .building permit # 17016-30000-16741	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77770	17041-10000-23000	1164 S ROBERTSON BLVD	90035	5	132B169   825	4332015022	[Q]C2-1-O	Central	Wilshire	South Robertson		2164.01	Electrical	Electrical	Commercial			07/10/2017 12:00:00 AM	09/15/2017 12:00:00 AM		Permit Finaled	09/20/2017 12:00:00 AM	ADDRESS	34.05542	-118.38354	PC for T24 for new decorative lighting. Total affected area is 355 sqft.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77771	14041-20000-20815	7755 N QUIMBY AVE	91304	12	189B097   962	2014032020	RS-1	South Valley	Canoga Park-West Hills-Winnetka-Woodland Hills	West Hills		1344.23	Electrical	Electrical	1 or 2 Family Dwelling			08/01/2014 12:00:00 AM	08/26/2014 12:00:00 AM		Permit Finaled	08/29/2014 12:00:00 AM	ADDRESS	34.21164	-118.63076	$0 permit fee due to senate bill 1222 from 2012New roof mounted PV system, total system size 13.77KW.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77772	16041-10001-08613	2853 E 6TH ST	90023	14	124-5A225 269	5185018012	R2-1	East Los Angeles	Boyle Heights	Boyle Heights	YES	2043.00	Electrical	Electrical	Apartment			05/27/2016 12:00:00 AM			Corrections Issued	05/27/2016 12:00:00 AM	ADDRESS	34.0344	-118.20655	CHANGES TO AN APPROVED SET. INSTALLING 400AMP MAIN SERVICE  PANEL  WITH 4 MAIN DISCONNECTS.  ALL EXISTING LOADS WERE MOVED TO A 100AMP SUB PANEL WITH 20 AMP PV BACK-FEED BREAKER.PV1 INSTALL 3.57 KW DC ROOF-MOUNTED SOLAR ARRAY FOR A SINGLE FAMILY HOME. (14) MODULES: HYUNDAI HIS-M255RG(1) INVERTER: ABB PVI-3.6-OUTD-S-US -A	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77773	14041-20000-31394	20376 W VIA GALILEO	91326	12	219B113   161	2701044013	RE9-1	North Valley	Chatsworth - Porter Ranch	Porter Ranch	YES	1082.02	Electrical	Electrical	1 or 2 Family Dwelling			11/12/2014 12:00:00 AM	12/16/2014 12:00:00 AM		Permit Finaled	01/28/2015 12:00:00 AM	ADDRESS	34.29559	-118.57795	PV1 Install roof-mounted solar array on a SFD. Interconnect with 300A MSP.System size: 10.2kW (3.6+3.6+3.0). Ungrounded system.51 255kW pv modules across 5 strings.Note: Permit fee $0.00 due to Senate Bill 1222 from 2012,  Note: Solar PV installation shall comply with FPB requirement No. 96 or approved plans by the LAFD.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77774	11041-20000-16795	2935 W LOS FELIZ BLVD	90039	13	157-5A207  92	5594006027	[Q]C4-1XL, [T][Q]M1-1VL	East Los Angeles	Northeast Los Angeles	Atwater Village		1881.00	Electrical	Electrical	Commercial			08/09/2011 12:00:00 AM	08/30/2011 12:00:00 AM		Permit Finaled	09/21/2011 12:00:00 AM	ADDRESS	34.12587	-118.26455	"PLAN CHECK T24 ENERGY/EMERGENCY LIGHTING TENANT IMPROVEMENT TO RETAIL SPACE ""PARTY CITY"". PERMIT FOR ELECTRICAL WORK ON EXISTING CKTS."	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77775	15041-10000-40282	13807 W DAVENTRY ST	91331	7	207B153   152	2619007019	R1-1-O	North Valley	Arleta - Pacoima	Pacoima		1044.01	Electrical	Electrical	1 or 2 Family Dwelling			12/01/2015 12:00:00 AM	12/01/2015 12:00:00 AM		Refund in Progress	08/22/2016 12:00:00 AM	ADDRESS	34.26704	-118.43384	PV1. Roof mounted installation to a single family home. (1) inverter: 5kw, (22) solar modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77776	18041-10000-32582	5858 W ABERNATHY DR	90045	11	099B169   101	4105006013	R1-1	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2760.00	Electrical	Electrical	1 or 2 Family Dwelling			08/27/2018 12:00:00 AM	09/26/2018 12:00:00 AM		Permit Finaled	02/20/2019 12:00:00 AM	ADDRESS	33.97081	-118.38396	PERMIT FEE IS $0.00 DUE TO SENATE BILL 1222.PV1. 11.7KW ROOFMOUNTED SOLAR SYSTEM + ENERGY STORAGE DEVICES 40.5KWH WITH  (36) MODULES INTERCONNECTING THROUGH A LOAD CENTER.	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77777	16041-20000-22032	12800 W WENTWORTH ST	91331	6	198B161   395	2629027902	(Q)MR1-1	North Valley	Sun Valley - La Tuna Canyon	Arleta		1212.10	Electrical	Electrical	Commercial			06/22/2016 12:00:00 AM			PC Info Complete	08/23/2016 12:00:00 AM	ADDRESS	34.23659	-118.41161	"2000 AMP SERVICE RECONNECT TO NEW SWITCHGEAR ""MSA""PANELS TO BE FUTURE, NO BRANCH CIRCUITS.  PLAN CHECK FO POWER ONLY."	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77778	18041-20000-47178	8974 N TAMPA AVE	91324	12	195B117    18	2784001024	C2-1L, P-1L	North Valley	Northridge	Northridge South		1153.01	Electrical	Electrical	Commercial			12/12/2018 12:00:00 AM	12/12/2018 12:00:00 AM		Permit Finaled	01/30/2019 12:00:00 AM	ADDRESS	34.23326	-118.55337	Change of use from retail to physical therapy office.  Plan check for energy.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77779	17041-10000-17526	1351 W SEPULVEDA BLVD	90501	15	045B193   785	7347018078	M2-1VL, M3-1VL	Harbor	Harbor Gateway	Harbor Gateway South		2932.02	Electrical	Electrical	Commercial			05/25/2017 12:00:00 AM	05/25/2017 12:00:00 AM		Permit Finaled	06/14/2018 12:00:00 AM	ADDRESS	33.81451	-118.30145	Title 24 plan check.  Replace HID fixtures with new LED fixtures.	N	N	Expanded Counter Plan Check	06/10/2024 12:00:00 AM
77780	19041-20000-00986	5732 N MAMMOTH AVE	91401	2	174B157   276	2246024016	R1-1	South Valley	Van Nuys - North Sherman Oaks	Greater Valley Glen		1286.02	Electrical	Electrical	1 or 2 Family Dwelling			01/09/2019 12:00:00 AM	01/09/2019 12:00:00 AM		Permit Finaled	05/01/2019 12:00:00 AM	ADDRESS	34.17495	-118.4322	Plan check for power only. Project site is a single family dwelling. Project scope is the addition of (2) battery back-up units onto an existing PV system.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77781	18041-20000-31727	1612 E PLEASANT AVE	90033	14	129A221   126	5174024011	R3-1-RIO-CUGU	East Los Angeles	Boyle Heights	Boyle Heights		2060.32	Electrical	Electrical	Apartment			08/21/2018 12:00:00 AM	04/17/2020 12:00:00 AM		Permit Finaled	05/24/2021 12:00:00 AM	ADDRESS	34.04803	-118.22072	Plan check for power and energy for 18 units apartment building 3 story. Total area: 9001 sq ft. B#18010-30000-02274Fire alarm Variance has been filed.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77782	12041-20000-30659	2103 N QUEENSFERRY ROAD PV-1	90049	11	138B133   340	4492016015	RE15-1-H	West Los Angeles	Brentwood - Pacific Palisades		YES	2624.00	Electrical	Electrical	1 or 2 Family Dwelling			12/20/2012 12:00:00 AM	12/20/2012 12:00:00 AM		Permit Finaled	03/20/2014 12:00:00 AM	ADDRESS	34.07378	-118.5063	PV-1. Addition to an existing PV system. 12 enphase microinverters. Main panel upgrade is a seperate permit.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77783	18041-20000-01359	555 S FLOWER ST 33rd  FL	90071	14	130-5A209 176	5151023400	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			01/12/2018 12:00:00 AM	03/22/2018 12:00:00 AM		Permit Finaled	08/23/2018 12:00:00 AM	ADDRESS	34.05048	-118.25755	TENANT IMPROVEMENT FOR ENTIRE 33RD FLOOR.  PLANCHECK FOR POWER AND ENERGY. BUILDING PERMIT #  18016-10000-00324	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77784	15041-10000-36495	961 S MANHATTAN PL Apt #2	90019	4	132B193  1175	5080001***	R4-1	Central	Wilshire	Greater Wilshire		2131.00	Electrical	Electrical	Commercial			10/30/2015 12:00:00 AM	11/03/2015 12:00:00 AM		Permit Finaled	03/04/2016 12:00:00 AM	ADDRESS	34.05393	-118.31026	PV1 roof mounted installation to a single family home. Scope: (1) inverter: 3.0 kw. (14) Modules.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77785	17041-10000-10200	14901 W VENTURA BLVD	91403	4	166-5A149 233	2264016024	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			03/30/2017 12:00:00 AM	03/30/2017 12:00:00 AM		Permit Finaled	06/07/2017 12:00:00 AM	ADDRESS	34.15257	-118.45764	PC FOR ENERGY ONLY. REMOVE EXISTING HID LIGHT FIXTURES AND REPLACE WITH NEW LED LIGHT FIXTURES, AFFECTED AREA 7800 SQ FT. OUTDOOR	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77786	18041-10000-24304	535 S GRAND AVE	90071	14	129A209    11	5151026005	C2-4D	Central	Central City	Downtown Los Angeles		2077.10	Electrical	Electrical	Commercial			06/29/2018 12:00:00 AM	08/01/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	34.04946	-118.25484	PC FOR INTERIOR RENOVATION (TI) AT FIRST FLOOR OF ( E ) HOTEL  (HIGH RISE). SCOPE INCLUDES NEW CIRCUITS, EQUIPMENT AND LIGHTS. TOTAL AFFECTED AREA 3788 SQ.FT. B#18016-10000-13308	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77787	19041-20000-16638	10155 N CASABA AVE	91311	12	204B113   343	2741006003	RE11-1	North Valley	Chatsworth - Porter Ranch	Chatsworth		1133.22	Electrical	Electrical	1 or 2 Family Dwelling			05/03/2019 12:00:00 AM	05/03/2019 12:00:00 AM		Permit Finaled	07/01/2019 12:00:00 AM	ADDRESS	34.25542	-118.5762	PLAN CHECK FOR ENERGY STORAGE SYSTEM TO EXISTING SFD WITH PV SYSTEMS. SCOPE OF WORK INCLUDES 13.2KWH TESLA POWER WALL AND 225A PANEL AND A 125A PANELS.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77788	19041-30001-26088	2013 S MORAY AVE	90732	15	012B193  1040	7562011006	R1-1XL	Harbor	San Pedro	Coastal San Pedro	YES	2974.00	Electrical	Electrical	1 or 2 Family Dwelling			07/09/2019 12:00:00 AM			PC Approved	08/13/2019 12:00:00 AM	ADDRESS	33.72638	-118.31288	Expedited per applicant request.Plan check for a PV1 roof-mounted PV system. System size is 11.23 kWdc/11.4 kWac and consists of (1) inverter, (21) modules, (2) load centers, (1) battery back-up unit, and (80) PV roof shingles (302 sq. ft.).	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77789	18041-20000-45026	7918 S EL MANOR AVE	90045	11	099B165   195	4109006018	R1V2	West Los Angeles	Westchester - Playa del Rey	Westchester/Playa del Rey		2770.00	Electrical	Electrical	1 or 2 Family Dwelling			11/27/2018 12:00:00 AM	11/27/2018 12:00:00 AM		Permit Finaled	01/09/2019 12:00:00 AM	ADDRESS	33.97033	-118.40078	Plan check for PV roof mounted system, system size: 10.56kW DC, 10.00kW AC with 32 PV Modules and 1 inverter(10.0kW)	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77790	13041-10000-27878	11269 W ACAMA ST	91602	2	165B173   763	2366016011	R1-1-RFA	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga Pass	Studio City		1432.00	Electrical	Electrical	1 or 2 Family Dwelling			10/08/2013 12:00:00 AM	11/13/2013 12:00:00 AM		Permit Expired	12/09/2015 12:00:00 AM	ADDRESS	34.14658	-118.37702	PV1 Plan check for 4.75KWDC roof mounted photovoltaic system. Transformerless system using SOLAREDGE SE5000A-US, Trina TSM-250PA05.08 modules with power optimizers	N	Y	Regular Plan Check	06/10/2024 12:00:00 AM
77791	13041-10000-16764	8616 S LA TIJERA BLVD	90045	11	096B169   586	4123004012	[Q]C2-1VL-CDO	West Los Angeles	Westchester - Playa del Rey	Westchester - Playa del Rey		2780.01	Electrical	Electrical	Commercial			06/25/2013 12:00:00 AM			PC Approved	06/25/2013 12:00:00 AM	ADDRESS	33.95933	-118.39173	Commercial office space TI, corridor and office space lighting.  Emergency egress lighting included.  Title 24 plan check only.  Permit to be issued at electrical plan check counter.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77792	15041-10000-05958	6300 W WILSHIRE BLVD SUITE 900	90048	5	135B177   500	5088014022	[Q]C4-2D-O	Central	Wilshire	Mid City West		2163.00	Electrical	Electrical	Commercial			03/02/2015 12:00:00 AM	03/05/2015 12:00:00 AM		Permit Expired	02/08/2017 12:00:00 AM	ADDRESS	34.06319	-118.36591	TI TO AN EXISTING HIGH RISE COMMERCIAL BUILDING.  ADDING NEW LIGHTING NEW CONTROLS AND PANEL.  NEWLY CONNECTED LOAD < 400 AMPS.  PLAN CHECK FOR ENERGY AND EMERGENCY LIGHTING ONLY.  TOTAL SQUARE FOOTAGE 4137. SCOPE OF WORK TO BE PERFORMED IN SUITE 900	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77793	10041-10000-09211	7850 N HASKELL AVE	91406	6	189B141   186	2206001017	M2-1	South Valley	Van Nuys - North Sherman Oaks	Lake Balboa		1273.00	Electrical	Electrical	Commercial			05/17/2010 12:00:00 AM	05/17/2010 12:00:00 AM		Permit Finaled	08/23/2010 12:00:00 AM	ADDRESS	34.21333	-118.47474	CENTRAL STATION MONITORING SYSTEM.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77794	18041-20000-10307	12045 N LOUISE AVE	91344	12	216B129   100	2606027055	RA-1-H	North Valley	Granada Hills - Knollwood	Granada Hills North	YES	1066.43	Electrical	Electrical	1 or 2 Family Dwelling			03/21/2018 12:00:00 AM	03/21/2018 12:00:00 AM		Issued	03/21/2018 12:00:00 AM	ADDRESS	34.29056	-118.51282	Plan check for a PV1 roof-mounted PV system. System size is 6.92 kWac/7.04 kWdc and consists of (1) inverter and (21) modules. Standard plan is not being used.	N	Y	Plan Check at Counter	06/10/2024 12:00:00 AM
77795	17041-10000-40986	1621 S MALCOLM AVE	90024	5	129B153    42	4325026021	[Q]RD1.5-1	West Los Angeles	Westwood	Westwood		2655.20	Electrical	Electrical	Apartment			11/13/2017 12:00:00 AM	11/13/2017 12:00:00 AM		Permit Finaled	07/18/2019 12:00:00 AM	ADDRESS	34.05355	-118.43747	NEW F.A SYSTEMS FOR 4-STORY (4 UNITS) APARTMENT BUILDING WITH SUBTERRANEAN PARKING LEVEL. (1) PANEL, (55) DEVICES	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM
77796	13041-20000-32511	12615 W BEATRICE ST	90066	11	105B161   985	4211006010	M2-1	West Los Angeles	Palms - Mar Vista - Del Rey	Del Rey		2756.02	Electrical	Electrical	Commercial			11/20/2013 12:00:00 AM			PC Info Complete	01/16/2014 12:00:00 AM	ADDRESS	33.98049	-118.41636	(((PROJECT LOCATED IN METHANE ZONE NO UNDERGROUND WORK TO BE DONE.. OVER HEAD SERVICE DROP.))))PC FOR POWER ONLY. EXISTING BUILDING NEW 800A SERVICE TO SUPPLY EXISTING LOADS. THIS IS A SECOND SERVICE TO EXISTING BUILDING	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77797	15041-10000-23459	18370 W BURBANK BLVD	91356	3	174B125   449	2160011029	[Q]C2-1L	South Valley	Encino - Tarzana	Tarzana		1394.01	Electrical	Electrical	Commercial			07/22/2015 12:00:00 AM			Reviewed by Supervisor	07/31/2015 12:00:00 AM	ADDRESS	34.17159	-118.53338	TI TO EXISTING NON OSHPOD3 A.S.C. (AMBLIGATORY SURGICAL CENTER). SCOPE OF WORK HAS BEEN IDENTIFIED ACCORDINGLY ON SLD.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77798	15041-20000-05684	7128 N VAN NUYS BLVD	91405	6	183B149   109	2217007040	C2-1L	South Valley	Van Nuys - North Sherman Oaks	Van Nuys		1279.10	Electrical	Electrical	Commercial			02/26/2015 12:00:00 AM			Reviewed by Supervisor	04/14/2015 12:00:00 AM	ADDRESS	34.20002	-118.44856	Plan check for power only.  2000 A service upgrade to existing commercial building.  New tenant panels connected to existing feeders and loads.	N	N	Regular Plan Check	06/10/2024 12:00:00 AM
77799	16041-20001-27980	15030 W VENTURA BLVD 6-B	91403	4	168B145  1087	2276005029	C2-1L	South Valley	Sherman Oaks-Studio City-Toluca Lake-Cahuenga	Sherman Oaks		1413.02	Electrical	Electrical	Commercial			08/26/2016 12:00:00 AM			PC Approved	08/30/2016 12:00:00 AM	ADDRESS	34.15272	-118.46063	Plan check for energy only. Change of use from massage parlor to pet grooming. Remodel interior space. New lighting. 1,017sqft. Permit pulled under parent application #16041-20000-27980.	N	N	Plan Check at Counter	06/10/2024 12:00:00 AM